Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Palmer(VCRS)_raw-data
SDR 5.7.6 -----Logger Information----- Model # Serial # 2541 Hardware Rev. 009-008-000 -----Site Information----- Site # 2541 Site Desc Palmer VCRS Project Code AEA Project Desc Valley Community for Recycling Solutions Site Location Site of proposed MCRS facility, next to landfill Site Elevation 98 m Latitude N 061° 35.460' Longitude W 149° 12.821' Time offset (hrs) -9 -----Sensor Information----- Channel # 1 Type 1 Description NRG #40 Anem, m/s Details Boom orientation: 320 deg True Serial Number SN: Height 29.6 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 2 Type 1 Description NRG #40 Anem, m/s Details Boom orientation: 130 deg True Serial Number SN: Height 29.6 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 3 Type 1 Description NRG #40 Anem, m/s Details Boom orientation: 100 deg True Serial Number SN: Height 20 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 4 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 5 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 6 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 7 Type 3 Description #200P Wind Vane Details Boom orientation: 75 deg True Serial Number SN: Height 25.9 m Scale Factor 0.351 Offset 255 Units deg Channel # 8 Type 0 Description No Sensor Details Serial Number SN: Height 0 Scale Factor 0 Offset 0 Units Channel # 9 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 10 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 11 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 12 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Date & Time Stamp CH1Avg CH1SD CH1Max CH1Min CH2Avg CH2SD CH2Max CH2Min CH3Avg CH3SD CH3Max CH3Min CH4Avg CH4SD CH4Max CH4Min CH5Avg CH5SD CH5Max CH5Min CH6Avg CH6SD CH6Max CH6Min CH7Avg CH7SD CH7Max CH7Min CH8Avg CH8SD CH8Max CH8Min CH9Avg CH9SD CH9Max CH9Min CH10Avg CH10SD CH10Max CH10Min CH11Avg CH11SD CH11Max CH11Min CH12Avg CH12SD CH12Max CH12Min 04/18/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/18/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 04/19/2005 11:00:00 0.4 0 1.1 0.4 0.4 0.1 2.3 0.4 0.4 0.1 2.3 0.4 255 0 255 255 0 0 0 0 04/19/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 12:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 1.1 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 13:50:00 0.5 0.6 5.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 41 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 14:00:00 0.4 0.4 4.6 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 16:00:00 0.5 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 255 1 255 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 16:10:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.4 2.3 0.4 306 47 351 255 0 0 0 0 -86.4 0 -86.4 -86.4 04/19/2005 16:20:00 0.7 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 8 18 26 255 0 0 0 0 -19.9 42 7.5 -86.4 04/19/2005 16:30:00 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 23 13 7 255 0 0 0 0 6.2 0 6.5 6 04/19/2005 16:40:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.9 0.4 334 64 329 255 0 0 0 0 5.9 0 6.2 5.7 04/19/2005 16:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 233 1 232 255 0 0 0 0 6.2 0 6.2 6 04/19/2005 17:00:00 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 265 56 243 255 0 0 0 0 6.2 0 6.2 6.2 04/19/2005 17:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 139 53 182 255 0 0 0 0 6.3 0 6.5 6.2 04/19/2005 17:20:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 228 4 229 255 0 0 0 0 6.5 0 6.7 6.5 04/19/2005 17:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 278 49 317 255 0 0 0 0 6.7 0 7 6.7 04/19/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 234 20 255 255 0 0 0 0 6.9 0 7 6.7 04/19/2005 17:50:00 0.6 0.4 1.9 0.4 0.4 0.3 1.5 0.4 0.4 0.2 1.9 0.4 235 64 19 255 0 0 0 0 7.1 0 7.3 7 04/19/2005 18:00:00 1.8 1 4.6 0.4 1.6 1.1 4.9 0.4 1.3 1 4.2 0.4 26 38 28 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 18:10:00 2.7 0.8 4.6 0.4 2.5 0.9 4.6 0.4 2 1 3.8 0.4 16 16 22 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 18:20:00 3.5 0.8 6.1 1.5 3.4 0.9 5.7 1.5 3 1 5.3 1.1 24 18 39 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 18:30:00 3.6 0.7 5.3 1.5 3.5 0.7 5.3 1.5 3.2 0.8 5.7 1.5 34 15 23 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 18:40:00 5.6 1.5 10.3 2.6 5.5 1.5 9.9 2.6 4.6 1.5 9.1 1.5 19 11 27 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 18:50:00 6.5 1.7 9.9 3.4 6.4 1.7 9.9 2.6 5.5 1.9 10.7 1.1 16 18 32 255 0 0 0 0 7.6 0 7.8 7.5 04/19/2005 19:00:00 6.8 1.6 11.8 3.4 6.7 1.6 11.8 3.4 5.7 1.7 11.8 2.6 22 13 21 255 0 0 0 0 7.8 0 7.8 7.8 04/19/2005 19:10:00 7.2 1.5 11.5 3.4 7.1 1.5 11.1 3.4 6.3 1.4 10.7 2.6 29 13 9 255 0 0 0 0 7.8 0 7.8 7.8 04/19/2005 19:20:00 7.6 1.3 11.1 4.9 7.5 1.3 11.1 4.6 6.7 1.1 9.1 3.8 38 12 49 255 0 0 0 0 7.8 0 7.8 7.8 04/19/2005 19:30:00 6.6 1.4 9.5 3 6.5 1.4 9.9 3.4 5.8 1.5 10.3 2.6 47 15 31 255 0 0 0 0 7.8 0 7.8 7.5 04/19/2005 19:40:00 5.8 1.2 9.1 2.3 5.8 1.3 9.5 2.3 5 1.3 7.6 1.5 51 17 45 255 0 0 0 0 7.7 0 7.8 7.5 04/19/2005 19:50:00 5.1 1.3 9.1 2.6 5.1 1.4 9.1 2.6 4.4 1.5 8.4 1.5 60 17 37 255 0 0 0 0 7.6 0 7.8 7.5 04/19/2005 20:00:00 5.4 1.4 9.9 2.3 5.3 1.4 9.9 2.3 4.7 1.3 9.5 1.9 46 16 37 255 0 0 0 0 7.5 0 7.8 7.5 04/19/2005 20:10:00 5.4 1.2 8.8 2.6 5.3 1.2 8.4 1.9 4.6 1.2 8.4 1.1 50 21 34 255 0 0 0 0 7.5 0 7.5 7.5 04/19/2005 20:20:00 5.1 1.1 8.4 2.6 5 1.1 8 2.6 4.2 1.2 7.2 1.9 57 17 53 255 0 0 0 0 7.4 0 7.5 7.3 04/19/2005 20:30:00 5 1.4 9.5 2.3 4.9 1.5 9.9 1.9 4.3 1.4 9.1 1.9 56 19 40 255 0 0 0 0 7.4 0 7.5 7.3 04/19/2005 20:40:00 7.4 2.1 12.2 3 7.3 2.2 12.6 3 6.2 2.1 11.1 1.9 42 18 20 255 0 0 0 0 7.4 0 7.5 7.3 04/19/2005 20:50:00 7.2 1.5 11.1 4.2 7.1 1.5 11.5 3.8 6.3 1.5 11.1 3.4 35 15 43 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 21:00:00 8 1.7 13.3 4.9 7.9 1.7 13.7 4.9 7.2 1.7 13 3.8 26 11 28 255 0 0 0 0 7.3 0 7.3 7.3 04/19/2005 21:10:00 7.6 1.8 12.6 3.8 7.5 1.8 12.2 3.8 6.4 1.7 11.8 2.3 31 13 38 255 0 0 0 0 7.3 0 7.3 7.3 04/19/2005 21:20:00 8.2 1.3 11.8 4.9 8.1 1.3 11.5 5.3 7 1.4 10.7 3.8 24 13 30 255 0 0 0 0 7.2 0 7.3 7.3 04/19/2005 21:30:00 8 1.7 13.7 4.6 8 1.7 13.7 4.6 6.7 1.8 12.6 3 26 11 18 255 0 0 0 0 7.1 0 7.3 7 04/19/2005 21:40:00 9.9 1.5 14.1 6.1 9.9 1.5 14.1 6.1 8.5 2 13.3 2.6 21 12 12 255 0 0 0 0 7 0 7.3 7 04/19/2005 21:50:00 9.5 1.9 14.5 4.9 9.5 1.9 14.1 5.3 7.9 2.1 12.2 3.8 23 11 9 255 0 0 0 0 6.9 0 7 7 04/19/2005 22:00:00 8.8 1.5 12.6 4.9 8.7 1.5 13 4.9 7.6 1.5 11.5 4.2 25 11 30 255 0 0 0 0 6.9 0 7 7 04/19/2005 22:10:00 9 1.8 13 4.6 9 1.8 13.3 4.2 7.4 1.8 11.5 3.4 19 11 8 255 0 0 0 0 7 0 7.3 7 04/19/2005 22:20:00 8.2 1.4 11.1 4.2 8.1 1.4 11.1 4.2 6.9 1.5 10.7 3.4 18 11 9 255 0 0 0 0 6.9 0 7 7 04/19/2005 22:30:00 7.7 1.3 12.2 4.9 7.6 1.3 11.8 4.6 6.4 1.5 10.7 3.4 21 12 12 255 0 0 0 0 6.9 0 7 6.7 04/19/2005 22:40:00 7.9 1.4 11.1 4.9 7.8 1.5 11.5 4.6 6.5 1.6 10.7 3.4 23 12 22 255 0 0 0 0 6.9 0 7 6.7 04/19/2005 22:50:00 7.3 1.3 10.3 3.8 7.2 1.4 10.3 3.8 6.2 1.5 9.9 2.6 23 12 15 255 0 0 0 0 6.9 0 7 7 04/19/2005 23:00:00 7.3 1.4 11.1 4.2 7.3 1.4 11.1 4.6 6.2 1.4 9.9 3.4 27 12 25 255 0 0 0 0 7 0 7.3 7 04/19/2005 23:10:00 7.6 1 10.3 4.6 7.6 1 10.3 4.6 6.6 1.1 9.9 3.8 32 11 33 255 0 0 0 0 7.3 0 7.3 7.3 04/19/2005 23:20:00 7.1 1.5 11.1 3.8 7 1.5 10.7 3.8 6.2 1.4 9.5 2.6 33 11 34 255 0 0 0 0 7.3 0 7.5 7.3 04/19/2005 23:30:00 7.5 1.3 11.1 3.8 7.5 1.4 11.1 3 6.5 1.5 10.7 3 39 12 43 255 0 0 0 0 7.6 0 7.5 7.5 04/19/2005 23:40:00 5.4 1.4 9.5 2.6 5.4 1.4 9.5 2.6 4.7 1.4 8.8 1.9 57 17 69 255 0 0 0 0 7.5 0 7.8 7.5 04/19/2005 23:50:00 4 1 7.6 1.9 4 1 7.2 1.5 3.3 1 5.7 0.4 71 19 51 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 00:00:00 4.8 1.3 7.2 1.1 4.8 1.3 7.6 1.5 4 1.4 6.8 0.7 55 18 64 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 00:10:00 5.1 1.4 9.1 2.6 5 1.5 9.1 2.3 4.3 1.3 8.4 1.9 53 18 51 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 00:20:00 4.6 1.3 8.8 1.9 4.6 1.3 8.4 1.5 4 1.2 8 1.5 62 17 65 255 0 0 0 0 7.5 0 7.8 7.5 04/20/2005 00:30:00 4.2 1 7.6 1.5 4.2 1.1 7.6 1.1 3.6 0.9 6.1 1.9 63 14 31 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 00:40:00 4.6 1.2 7.6 2.3 4.5 1.2 7.6 1.9 3.8 1.2 6.8 1.1 72 17 64 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 00:50:00 4.7 1.1 8.4 2.3 4.6 1.1 8 2.6 4.1 1.1 8 1.9 60 22 20 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 01:00:00 4.7 1.2 8.8 2.3 4.6 1.2 8.8 2.3 4 1 6.5 1.5 62 22 12 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 01:10:00 3.6 1 7.2 1.5 3.5 1 6.1 1.5 2.9 0.8 4.6 1.1 82 18 70 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 01:20:00 4.6 0.9 7.2 2.6 4.6 0.9 7.6 2.3 3.8 1 8 1.9 84 18 94 255 0 0 0 0 7.3 0 7.3 7.3 04/20/2005 01:30:00 4 0.8 6.1 1.9 3.9 0.9 6.1 1.9 3.3 0.9 5.7 1.1 73 22 60 255 0 0 0 0 7.3 0 7.3 7.3 04/20/2005 01:40:00 4.6 1.5 8 0.7 4.5 1.5 8 1.1 3.9 1.4 7.2 0.4 82 15 55 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 01:50:00 4.2 1 7.2 1.5 4.1 1 7.2 1.9 3.7 0.9 6.8 1.5 74 14 79 255 0 0 0 0 7.5 0 7.5 7.3 04/20/2005 02:00:00 4.9 0.9 7.2 2.6 4.9 1 6.8 2.3 4 1 6.8 1.9 79 15 83 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 02:10:00 4.4 1.1 8.4 1.1 4.3 1.1 8 1.5 3.5 1.1 8 1.5 93 17 112 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 02:20:00 4.9 1.3 8.8 2.3 4.8 1.5 8.8 1.9 4.2 1.3 8 1.9 86 17 92 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 02:30:00 4.7 1.1 7.2 1.9 4.6 1.1 7.2 1.9 4 1.1 6.8 1.1 90 13 88 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 02:40:00 3.9 0.7 5.7 1.9 3.8 0.7 5.7 1.9 3.1 0.7 4.6 1.9 82 17 74 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 02:50:00 4.4 1.3 7.6 1.9 4.4 1.3 7.6 1.9 3.8 1.3 7.6 1.5 75 19 44 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 03:00:00 5 1.2 8.4 2.3 4.9 1.3 8.4 2.3 4.3 1 6.8 2.3 77 17 64 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 03:10:00 5.3 1.1 7.6 1.9 5.3 1.1 8 2.6 4.4 1.2 7.2 1.1 78 18 97 255 0 0 0 0 7.3 0 7.5 7.3 04/20/2005 03:20:00 4.8 0.9 7.2 2.6 4.8 0.9 7.6 2.6 4.1 1 6.8 1.9 79 15 62 255 0 0 0 0 7.3 0 7.3 7.3 04/20/2005 03:30:00 6.5 1.2 10.7 3.8 6.5 1.2 10.7 3.8 5.6 1.2 9.1 2.6 62 18 80 255 0 0 0 0 7.3 0 7.3 7.3 04/20/2005 03:40:00 7 1.8 11.8 3 7 1.8 12.2 3 6 1.7 9.9 1.9 51 18 45 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 03:50:00 7.4 1.6 11.5 3 7.4 1.5 11.5 3.8 6.2 1.6 10.3 2.3 41 15 17 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 04:00:00 7.9 2.2 15.3 1.9 7.9 2.2 14.9 2.6 7 2 12.6 2.3 44 15 35 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 04:10:00 7.1 1.4 11.1 3.8 7 1.5 11.5 3 6.1 1.5 11.1 2.6 40 16 40 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 04:20:00 7.9 1.7 12.6 4.9 7.9 1.7 12.2 4.6 6.8 1.7 11.8 3.4 30 13 38 255 0 0 0 0 7.5 0 7.5 7.3 04/20/2005 04:30:00 7.9 1.7 13.3 3.8 7.9 1.7 13 3.8 6.6 1.7 12.2 3 26 15 30 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 04:40:00 7.6 1.6 13 4.6 7.6 1.6 13 4.2 6.2 1.7 11.1 3 19 17 11 255 0 0 0 0 7.7 0 7.8 7.5 04/20/2005 04:50:00 6.9 2.3 12.6 2.6 6.8 2.4 13 2.6 5.5 2.3 12.6 2.3 24 17 34 255 0 0 0 0 7.6 0 7.8 7.5 04/20/2005 05:00:00 7.2 1.4 11.1 4.2 7.2 1.4 11.1 3.8 6 1.5 10.3 2.3 20 16 30 255 0 0 0 0 7.8 0 7.8 7.8 04/20/2005 05:10:00 7.7 2.1 12.6 3.4 7.7 2.1 12.6 3 6.3 2.1 12.2 1.9 14 17 24 255 0 0 0 0 7.8 0 8 7.8 04/20/2005 05:20:00 6.7 1.2 10.7 4.2 6.7 1.2 10.7 4.2 5.3 1.2 8.8 2.6 21 15 10 255 0 0 0 0 7.8 0 7.8 7.8 04/20/2005 05:30:00 7.2 1.7 11.8 3.4 7.2 1.7 12.2 3.4 5.8 1.7 10.7 1.9 17 15 22 255 0 0 0 0 7.8 0 7.8 7.8 04/20/2005 05:40:00 7.6 1.9 13.7 3.4 7.5 2 14.1 3.4 5.9 1.8 11.1 1.9 15 13 21 255 0 0 0 0 7.8 0 8 7.8 04/20/2005 05:50:00 7.8 1.7 12.6 3.4 7.7 1.7 12.2 3.4 6.3 1.7 11.1 3 19 12 23 255 0 0 0 0 7.9 0 8 7.8 04/20/2005 06:00:00 7.8 1.6 11.8 3.8 7.8 1.6 11.8 4.2 6.3 1.7 10.3 2.3 19 13 1 255 0 0 0 0 8 0 8 7.8 04/20/2005 06:10:00 7.4 1.7 12.2 3.4 7.4 1.7 11.8 3 6.3 1.7 11.1 1.9 21 15 31 255 0 0 0 0 8 0 8.3 7.8 04/20/2005 06:20:00 8.4 1.9 15.3 3.8 8.4 2 15.3 3.8 7.1 1.9 13.7 3.4 18 13 13 255 0 0 0 0 8.1 0 8.3 8 04/20/2005 06:30:00 8.7 1.6 13 4.2 8.6 1.6 13 4.2 7.4 1.7 11.8 3 19 12 20 255 0 0 0 0 8 0 8.3 7.8 04/20/2005 06:40:00 8.9 2 14.5 4.9 8.9 2 14.5 4.6 7.3 2 13.3 3 15 12 31 255 0 0 0 0 8 0 8.3 7.8 04/20/2005 06:50:00 8.4 1.8 13.7 3 8.4 1.8 13 3 6.9 1.9 12.2 3 17 14 14 255 0 0 0 0 8 0 8.3 8 04/20/2005 07:00:00 8.2 1.7 13 3.8 8.1 1.7 13 4.2 6.5 2 13 2.6 12 13 26 255 0 0 0 0 8.1 0 8.3 8 04/20/2005 07:10:00 8.7 1.6 13 5.3 8.6 1.6 13 4.9 7.4 1.7 12.6 3.4 19 15 32 255 0 0 0 0 8 0 8.3 8 04/20/2005 07:20:00 7.4 1.7 11.5 3.4 7.3 1.7 11.5 3 6.1 1.5 11.1 3 23 14 25 255 0 0 0 0 8 0 8.3 7.8 04/20/2005 07:30:00 8.4 2.1 14.1 4.6 8.4 2.2 14.1 4.6 7.2 2 13.3 3 26 13 22 255 0 0 0 0 7.9 0 8 7.8 04/20/2005 07:40:00 8.4 1.9 13.3 4.6 8.3 1.9 13.3 4.6 7.1 1.8 11.8 3.4 22 12 4 255 0 0 0 0 7.9 0 8 7.8 04/20/2005 07:50:00 9.2 1.7 13.3 5.3 9.2 1.7 13.7 5.3 8 1.6 12.2 4.6 23 11 20 255 0 0 0 0 8 0 8.3 7.8 04/20/2005 08:00:00 8 1.5 11.1 4.9 8 1.5 11.5 4.6 6.9 1.5 10.3 3.4 21 12 6 255 0 0 0 0 8 0 8.3 8 04/20/2005 08:10:00 9.3 1.7 14.5 5.7 9.2 1.7 14.5 5.3 7.8 1.5 11.8 4.6 21 12 21 255 0 0 0 0 8.2 0 8.3 8.3 04/20/2005 08:20:00 9.1 1.8 13.3 4.9 9.1 1.9 13.3 4.6 7.8 1.9 12.6 3.8 26 11 28 255 0 0 0 0 8.2 0 8.3 8.3 04/20/2005 08:30:00 8 1.7 12.2 3.4 8 1.8 13.7 4.2 6.9 1.9 11.1 1.5 27 12 19 255 0 0 0 0 8.2 0 8.3 8.3 04/20/2005 08:40:00 8.2 1.6 13.3 4.6 8.2 1.6 13.7 4.9 6.9 1.8 13.7 3 20 15 22 255 0 0 0 0 8.3 0 8.5 8.3 04/20/2005 08:50:00 8.9 1.8 14.1 4.6 8.9 1.9 14.1 4.6 7.3 2.1 12.6 1.9 17 12 25 255 0 0 0 0 8.4 0 8.5 8.3 04/20/2005 09:00:00 8.5 1.6 12.6 4.9 8.4 1.6 13 4.6 7.1 1.8 12.2 3.4 21 12 31 255 0 0 0 0 8.4 0 8.5 8.5 04/20/2005 09:10:00 8.6 1.7 13 4.6 8.5 1.7 13 4.9 7.3 2 11.8 2.6 26 13 40 255 0 0 0 0 8.5 0.1 8.8 8.5 04/20/2005 09:20:00 9 1.8 13.3 4.9 8.9 1.8 13.3 4.9 7.7 1.9 12.6 3.8 21 10 17 255 0 0 0 0 8.7 0 9 8.8 04/20/2005 09:30:00 8.4 2.2 13.7 4.2 8.4 2.2 13.7 3.8 7.3 2.3 13 2.6 24 14 26 255 0 0 0 0 8.9 0 9 8.8 04/20/2005 09:40:00 7.2 1.7 11.8 3.8 7.2 1.7 11.8 3.8 6.1 1.7 10.7 1.9 17 15 30 255 0 0 0 0 9 0 9 8.8 04/20/2005 09:50:00 6.6 1.9 11.8 3.8 6.6 1.9 11.8 3.4 5.3 1.8 10.7 1.9 21 13 14 255 0 0 0 0 9.2 0 9.3 9 04/20/2005 10:00:00 6.8 1.5 11.5 3.4 6.7 1.6 11.1 3 5.6 1.5 10.3 2.6 18 17 13 255 0 0 0 0 9.2 0 9.3 9.3 04/20/2005 10:10:00 7.4 1.8 12.2 3.8 7.4 1.8 12.2 3.8 6 1.7 10.7 2.6 21 13 25 255 0 0 0 0 9.3 0 9.3 9.3 04/20/2005 10:20:00 7.9 1.7 12.6 3.8 7.9 1.7 12.6 4.2 6.5 1.7 11.8 3 23 16 347 255 0 0 0 0 9.2 0 9.3 9.3 04/20/2005 10:30:00 7 1.7 10.7 3.4 6.9 1.7 11.1 3 5.6 1.7 9.9 2.3 15 14 359 255 0 0 0 0 9.4 0 9.6 9.3 04/20/2005 10:40:00 8.5 2.1 13.3 2.6 8.4 2.1 13.7 2.6 7 2.1 12.6 2.3 17 13 11 255 0 0 0 0 9.4 0 9.6 9.3 04/20/2005 10:50:00 8.5 1.7 13 3.4 8.5 1.7 13 3.8 7.1 1.8 11.5 2.6 16 13 26 255 0 0 0 0 9.3 0 9.6 9.3 04/20/2005 11:00:00 8.7 1.8 14.9 4.6 8.7 1.8 14.5 4.2 7.3 1.8 13 3.4 19 15 7 255 0 0 0 0 9.4 0 9.6 9.3 04/20/2005 11:10:00 7.6 1.5 12.2 4.6 7.6 1.5 12.2 4.2 6.5 1.7 11.5 2.3 21 13 8 255 0 0 0 0 9.5 0 9.8 9.3 04/20/2005 11:20:00 8.5 1.7 13.7 5.3 8.5 1.7 14.5 4.9 7.1 2 14.5 3.4 16 13 31 255 0 0 0 0 9.8 0 9.8 9.6 04/20/2005 11:30:00 8.2 2.1 13.3 3.4 8.1 2.1 13.3 3.4 6.5 2.2 11.8 1.9 13 13 6 255 0 0 0 0 10 0 10.1 9.8 04/20/2005 11:40:00 8.2 1.6 12.6 4.6 8.2 1.7 12.6 4.2 6.8 1.8 11.8 3.4 16 15 4 255 0 0 0 0 9.9 0 10.1 9.8 04/20/2005 11:50:00 8.3 2.1 13.7 4.6 8.3 2.1 13.7 4.6 7 2.2 12.6 2.6 15 13 3 255 0 0 0 0 10 0 10.1 9.8 04/20/2005 12:00:00 6.9 1.5 10.7 2.3 6.8 1.5 10.7 2.3 5.6 1.6 9.1 1.9 19 13 1 255 0 0 0 0 10 0 10.1 9.8 04/20/2005 12:10:00 7.3 1.8 11.1 3.4 7.2 1.9 11.5 3.4 6 1.9 10.3 2.6 20 13 10 255 0 0 0 0 10.2 0 10.6 9.8 04/20/2005 12:20:00 7.6 1.5 11.8 2.6 7.6 1.6 11.5 2.6 6.4 1.5 10.7 2.3 21 12 54 255 0 0 0 0 10.6 0 10.9 10.3 04/20/2005 12:30:00 7.9 1.7 11.8 3 7.8 1.7 11.5 2.6 6.7 1.8 11.5 1.9 18 11 44 255 0 0 0 0 10.9 0 11.1 10.9 04/20/2005 12:40:00 6.6 1.5 11.5 3.4 6.5 1.5 11.5 3.4 5.5 1.3 11.1 2.6 22 15 25 255 0 0 0 0 11.2 0.1 11.4 11.1 04/20/2005 12:50:00 8 1.8 13 3.8 7.9 1.8 13 3.4 6.7 1.8 11.5 2.3 23 15 26 255 0 0 0 0 10.9 0.1 11.4 10.6 04/20/2005 13:00:00 9.4 1.5 13.3 5.7 9.3 1.5 13.7 5.7 7.9 1.7 11.8 3.4 17 12 15 255 0 0 0 0 10.6 0 10.9 10.6 04/20/2005 13:10:00 8.1 1.7 13 3 8.1 1.7 13 3 6.8 1.8 12.2 2.6 20 13 25 255 0 0 0 0 10.7 0 10.9 10.6 04/20/2005 13:20:00 8.4 1.2 11.5 4.9 8.3 1.3 11.5 4.9 6.9 1.6 11.5 3.4 20 12 20 255 0 0 0 0 10.7 0 10.9 10.6 04/20/2005 13:30:00 7.1 1.5 11.1 3.4 7.1 1.5 11.1 3.4 6 1.7 10.7 3 22 15 12 255 0 0 0 0 10.9 0 11.1 10.6 04/20/2005 13:40:00 6.9 1.7 11.1 3 6.9 1.8 11.1 2.6 5.5 1.7 10.3 1.9 15 14 358 255 0 0 0 0 11.3 0 11.4 11.1 04/20/2005 13:50:00 7.9 1.5 12.2 4.9 7.9 1.5 11.8 4.9 6.5 1.6 11.1 3 16 14 28 255 0 0 0 0 11.3 0 11.7 11.1 04/20/2005 14:00:00 7.5 1.3 11.1 4.6 7.4 1.3 11.1 4.6 6.2 1.4 9.9 3 21 12 32 255 0 0 0 0 11.3 0 11.7 11.1 04/20/2005 14:10:00 7.3 1.6 11.8 3.8 7.3 1.6 11.5 3.8 6.2 1.7 10.7 2.6 16 12 27 255 0 0 0 0 11.3 0 11.7 11.1 04/20/2005 14:20:00 6.9 1.4 9.9 3 6.9 1.4 9.9 3 5.7 1.6 9.1 1.9 17 13 6 255 0 0 0 0 11.1 0 11.4 11.1 04/20/2005 14:30:00 7.5 1.5 11.1 3.4 7.4 1.5 10.7 3.4 6.2 1.5 10.3 3 16 10 4 255 0 0 0 0 10.9 0.1 11.1 10.6 04/20/2005 14:40:00 8.1 1 10.3 5.3 8 1 10.7 5.7 7.1 1.3 9.5 3.4 22 9 24 255 0 0 0 0 10.7 0 10.9 10.6 04/20/2005 14:50:00 5 1.3 9.9 2.6 4.9 1.4 10.3 2.6 3.9 1.6 10.7 1.5 10 15 3 255 0 0 0 0 10.9 0 11.1 10.6 04/20/2005 15:00:00 6.2 1.6 9.1 2.3 6.2 1.6 9.1 2.3 5.3 1.8 8.8 1.5 18 14 5 255 0 0 0 0 11.2 0 11.4 11.1 04/20/2005 15:10:00 7 1.6 11.1 3 7 1.6 11.1 3 5.8 1.6 9.5 2.3 14 13 18 255 0 0 0 0 11.2 0 11.4 11.1 04/20/2005 15:20:00 5.9 1.2 8.8 2.6 5.8 1.3 8.8 2.3 4.7 1.5 8.8 1.1 17 16 52 255 0 0 0 0 11.5 0.2 11.9 11.1 04/20/2005 15:30:00 7.1 1.3 11.8 4.2 7.1 1.3 11.8 3.8 6 1.7 9.5 1.9 16 12 10 255 0 0 0 0 11.7 0 11.9 11.7 04/20/2005 15:40:00 7.2 1.5 10.7 3.4 7.2 1.5 11.1 3.4 5.9 1.6 9.9 1.9 13 13 9 255 0 0 0 0 11.6 0 11.9 11.4 04/20/2005 15:50:00 6.9 1.2 10.3 4.2 6.8 1.2 10.3 4.6 5.9 1.3 9.5 3 25 14 27 255 0 0 0 0 11.8 0.1 12.2 11.7 04/20/2005 16:00:00 6.7 1.3 10.3 3.8 6.6 1.3 10.3 3.4 5.5 1.3 9.5 3 38 23 12 255 0 0 0 0 11.7 0 11.9 11.7 04/20/2005 16:10:00 3.5 0.8 6.5 1.5 3.4 0.9 6.5 1.5 3.1 0.8 6.5 0.7 95 22 64 255 0 0 0 0 10.5 0.4 11.9 10.1 04/20/2005 16:20:00 3.4 0.6 4.9 1.5 3.3 0.6 4.9 1.5 3 0.7 4.6 1.1 92 14 79 255 0 0 0 0 10.2 0 10.3 10.1 04/20/2005 16:30:00 2.6 1.2 6.5 0.4 2.5 1.2 6.5 0.4 2.2 1.1 5.7 0.4 66 28 8 255 0 0 0 0 10.5 0.1 10.9 10.3 04/20/2005 16:40:00 4.9 1.6 11.1 1.9 4.8 1.7 10.7 0.7 4.3 1.5 9.5 0.7 43 23 21 255 0 0 0 0 11.1 0.3 11.7 10.6 04/20/2005 16:50:00 7 1.6 11.1 3 6.9 1.7 11.1 3.4 6 1.7 9.9 2.6 27 15 27 255 0 0 0 0 11.7 0 11.9 11.7 04/20/2005 17:00:00 7.1 1.5 11.8 4.6 7 1.5 12.2 4.2 6 1.6 11.5 3 21 14 37 255 0 0 0 0 11.7 0 11.9 11.7 04/20/2005 17:10:00 8 1.3 11.8 3.8 7.9 1.3 11.8 3.4 6.7 1.5 11.1 3 21 15 17 255 0 0 0 0 11.9 0 11.9 11.9 04/20/2005 17:20:00 8.1 1.5 11.8 4.2 8 1.5 11.5 4.2 6.6 1.6 10.7 3 12 11 12 255 0 0 0 0 11.9 0 11.9 11.7 04/20/2005 17:30:00 7.7 1.4 11.1 3.8 7.7 1.5 11.1 4.2 6.6 1.4 9.9 2.6 21 13 34 255 0 0 0 0 11.5 0.1 11.7 11.4 04/20/2005 17:40:00 6.7 1.7 11.5 3.4 6.6 1.7 11.5 2.6 5.7 1.8 9.9 0.4 15 15 27 255 0 0 0 0 11.3 0 11.4 11.1 04/20/2005 17:50:00 8 1.7 11.1 3.4 7.9 1.7 11.1 4.2 6.8 1.7 10.7 2.3 19 12 27 255 0 0 0 0 11.3 0 11.7 11.1 04/20/2005 18:00:00 7.6 1.3 10.7 3.8 7.5 1.3 10.7 4.2 6.1 1.5 9.9 1.9 14 14 16 255 0 0 0 0 11.3 0 11.4 11.1 04/20/2005 18:10:00 7.7 1.7 12.6 3.8 7.7 1.7 12.6 3.4 6.4 1.7 11.5 2.6 19 15 10 255 0 0 0 0 11.1 0 11.4 11.1 04/20/2005 18:20:00 9.4 1.3 13.7 6.8 9.4 1.4 13.7 6.5 8.4 1.8 13.3 4.2 22 10 17 255 0 0 0 0 11 0 11.1 10.9 04/20/2005 18:30:00 7.9 1.5 11.8 4.6 7.9 1.5 12.2 4.6 6.7 1.7 10.3 3 21 13 12 255 0 0 0 0 10.7 0 10.9 10.6 04/20/2005 18:40:00 8.2 1.5 12.6 5.3 8.1 1.5 13 5.3 7.1 1.7 11.8 3.8 25 11 14 255 0 0 0 0 10.6 0 10.6 10.6 04/20/2005 18:50:00 7.2 1.1 10.3 3.8 7.1 1.1 9.9 3.8 6.2 1.2 9.5 1.9 23 13 17 255 0 0 0 0 10.5 0 10.6 10.6 04/20/2005 19:00:00 8.4 1 11.5 5.7 8.3 1.1 11.5 5.7 7.1 1.4 12.2 3.4 22 11 3 255 0 0 0 0 10.3 0.1 10.6 10.3 04/20/2005 19:10:00 7 1.2 11.1 3 7 1.3 11.1 3 6 1.4 11.1 3 24 13 29 255 0 0 0 0 10 0 10.3 9.8 04/20/2005 19:20:00 6.4 1 9.1 4.2 6.3 1.1 9.1 4.2 5.7 1.2 8.8 3 32 12 39 255 0 0 0 0 9.8 0 9.8 9.6 04/20/2005 19:30:00 6.4 1.3 9.5 3.4 6.3 1.3 9.9 3 5.4 1.3 9.1 3 23 11 10 255 0 0 0 0 9.5 0 9.6 9.3 04/20/2005 19:40:00 6.8 1.2 10.3 3.8 6.8 1.2 10.3 3.8 6.1 1.2 9.5 3 30 12 22 255 0 0 0 0 9.3 0 9.6 9.3 04/20/2005 19:50:00 6 1.1 9.1 3 6 1.1 9.5 3.4 5.2 1.2 8 2.3 35 14 18 255 0 0 0 0 9.2 0 9.3 9 04/20/2005 20:00:00 7 1.1 9.9 3.4 7 1.2 9.5 3.4 6.2 1.3 9.5 1.9 29 12 41 255 0 0 0 0 9 0 9.3 9 04/20/2005 20:10:00 6.6 1.3 10.3 3.4 6.5 1.3 10.3 3.4 5.7 1.3 9.1 2.6 29 13 40 255 0 0 0 0 9 0 9.3 9 04/20/2005 20:20:00 7 1.2 10.7 4.2 6.9 1.2 10.7 4.2 6.1 1.2 9.9 3.4 25 11 40 255 0 0 0 0 8.9 0 9 8.8 04/20/2005 20:30:00 6.3 1.6 11.1 2.6 6.2 1.6 10.7 2.6 5.3 1.5 10.3 1.9 39 15 31 255 0 0 0 0 8.9 0 9 8.8 04/20/2005 20:40:00 4.6 0.9 6.8 2.6 4.5 1 6.8 2.3 3.8 1 7.2 1.5 58 17 36 255 0 0 0 0 8.8 0 9 8.5 04/20/2005 20:50:00 4.5 1.1 7.2 1.9 4.4 1.1 7.2 2.3 3.6 1.1 6.5 1.1 58 15 53 255 0 0 0 0 8.4 0 8.5 8.3 04/20/2005 21:00:00 4.4 1 6.8 2.3 4.3 1.1 6.8 1.9 3.6 1 6.5 1.5 65 14 44 255 0 0 0 0 8.4 0 8.5 8.3 04/20/2005 21:10:00 5.8 1 8.4 3.4 5.8 1 8 3.4 4.8 1.1 7.6 2.6 52 11 60 255 0 0 0 0 8.4 0 8.5 8.3 04/20/2005 21:20:00 4.3 1.1 7.6 2.3 4.2 1.1 7.2 2.3 3.6 1.1 7.2 1.1 60 14 40 255 0 0 0 0 8.3 0 8.5 8.3 04/20/2005 21:30:00 4.7 1 6.8 2.3 4.6 1 7.2 2.6 3.8 1.1 6.8 1.5 56 13 43 255 0 0 0 0 8.1 0 8.3 8 04/20/2005 21:40:00 3.1 0.7 4.9 1.1 3 0.8 5.3 1.1 2.6 0.7 4.2 0.7 66 13 38 255 0 0 0 0 7.9 0 8.3 7.8 04/20/2005 21:50:00 4.3 1 6.8 2.3 4.2 1 6.5 2.3 3.5 1 6.1 1.5 49 15 40 255 0 0 0 0 7.9 0 8 7.8 04/20/2005 22:00:00 4.5 1 6.8 1.5 4.4 1.1 6.8 1.5 3.6 1 5.7 1.1 58 15 36 255 0 0 0 0 7.9 0 8 7.8 04/20/2005 22:10:00 4.7 0.9 8 2.6 4.6 0.9 8 2.3 3.9 0.8 6.5 2.3 69 14 65 255 0 0 0 0 7.8 0 8 7.8 04/20/2005 22:20:00 4.1 0.8 5.7 2.3 4 0.9 5.7 2.3 3.4 0.8 5.7 1.9 69 13 74 255 0 0 0 0 7.8 0 7.8 7.8 04/20/2005 22:30:00 3.8 0.9 6.5 1.9 3.7 0.9 6.5 1.5 3.1 0.8 5.3 1.5 67 14 67 255 0 0 0 0 7.8 0 7.8 7.5 04/20/2005 22:40:00 3.4 0.8 5.3 1.1 3.3 0.8 5.3 1.1 2.8 0.8 4.6 0.7 65 14 37 255 0 0 0 0 7.5 0 7.8 7.5 04/20/2005 22:50:00 3.7 0.7 6.1 2.3 3.6 0.7 6.1 1.5 2.9 0.8 5.3 0.7 64 16 76 255 0 0 0 0 7.4 0 7.5 7.3 04/20/2005 23:00:00 3.6 1.1 6.8 1.1 3.5 1.2 6.8 1.1 3 1 6.5 1.1 65 16 73 255 0 0 0 0 7.5 0 7.8 7.5 04/20/2005 23:10:00 3.4 1 5.7 1.1 3.3 1 6.1 0.7 2.9 1 5.3 0.7 77 17 59 255 0 0 0 0 7.6 0 7.8 7.3 04/20/2005 23:20:00 2.5 0.8 4.6 0.4 2.4 0.8 5.3 0.4 1.9 0.9 4.2 0.4 76 17 59 255 0 0 0 0 7.4 0.1 7.5 7.3 04/20/2005 23:30:00 3.5 0.7 5.3 1.9 3.4 0.8 5.3 1.5 2.9 0.7 4.9 1.1 81 14 65 255 0 0 0 0 7.3 0 7.3 7.3 04/20/2005 23:40:00 3.6 0.6 4.9 1.9 3.5 0.6 4.9 1.5 3 0.6 4.9 1.5 90 11 78 255 0 0 0 0 7 0 7.3 7 04/20/2005 23:50:00 3.8 0.6 5.3 2.3 3.7 0.6 4.9 2.3 3.1 0.8 4.6 1.1 80 11 75 255 0 0 0 0 6.9 0 7.3 7 04/21/2005 00:00:00 4.3 0.7 6.1 2.3 4.3 0.7 6.5 1.9 3.6 0.8 6.1 0.7 80 11 83 255 0 0 0 0 7.2 0 7.3 7 04/21/2005 00:10:00 4.6 0.8 6.8 2.3 4.6 0.8 6.5 2.3 3.7 0.8 6.5 1.1 72 11 69 255 0 0 0 0 7.4 0.1 7.8 7.3 04/21/2005 00:20:00 4.1 0.8 6.5 2.6 4.1 0.8 6.5 2.3 3.3 0.8 5.3 1.1 74 12 66 255 0 0 0 0 7.7 0 7.8 7.5 04/21/2005 00:30:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.5 2.8 0.8 4.6 1.1 71 15 76 255 0 0 0 0 7.6 0 7.8 7.5 04/21/2005 00:40:00 3.7 0.7 4.9 1.9 3.6 0.7 5.7 1.5 2.8 0.7 4.9 1.1 76 10 74 255 0 0 0 0 7.5 0 7.8 7.5 04/21/2005 00:50:00 3.4 0.5 4.6 2.3 3.3 0.6 4.6 1.9 2.7 0.6 4.2 1.1 80 13 72 255 0 0 0 0 7.4 0 7.5 7.5 04/21/2005 01:00:00 3.1 0.7 4.6 0.7 3.1 0.7 4.9 0.7 2.4 0.7 4.2 0.4 91 12 97 255 0 0 0 0 7.5 0 7.8 7.3 04/21/2005 01:10:00 3 0.8 4.9 1.1 2.9 0.8 4.6 1.1 2.3 0.8 4.2 0.4 85 13 89 255 0 0 0 0 7.4 0.1 7.5 7.3 04/21/2005 01:20:00 3 0.7 4.9 1.5 3 0.8 5.3 1.1 2.5 0.7 4.2 0.7 92 11 86 255 0 0 0 0 7.4 0 7.5 7.3 04/21/2005 01:30:00 2.7 0.8 4.9 1.1 2.6 0.9 4.9 0.7 2.1 0.9 4.2 0.4 84 14 71 255 0 0 0 0 7.4 0 7.5 7.3 04/21/2005 01:40:00 3.3 0.7 4.9 1.5 3.3 0.7 4.9 1.5 2.5 0.8 4.6 0.7 88 11 84 255 0 0 0 0 7.3 0 7.3 7.3 04/21/2005 01:50:00 3.2 0.6 4.9 1.5 3.1 0.6 4.6 1.1 2.2 0.7 3.8 0.7 87 14 108 255 0 0 0 0 7.3 0 7.5 7.3 04/21/2005 02:00:00 2.9 0.6 4.2 1.5 2.7 0.6 4.2 1.1 2 0.7 3.8 0.4 82 9 83 255 0 0 0 0 7.3 0 7.3 7.3 04/21/2005 02:10:00 3.4 0.5 5.3 2.3 3.4 0.6 5.3 2.3 2.7 0.6 4.2 1.1 89 9 91 255 0 0 0 0 7.2 0 7.3 7.3 04/21/2005 02:20:00 2.9 0.6 4.6 1.1 2.8 0.6 4.6 1.5 2.1 0.7 3.8 0.7 85 9 86 255 0 0 0 0 7.2 0 7.3 7.3 04/21/2005 02:30:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 1.9 0.8 3.4 0.4 91 11 81 255 0 0 0 0 7.1 0 7.3 7 04/21/2005 02:40:00 2.8 0.5 3.8 0.4 2.7 0.5 3.8 1.1 2 0.6 3.8 0.4 87 10 69 255 0 0 0 0 7.1 0 7.3 7 04/21/2005 02:50:00 2.8 0.5 3.8 1.9 2.6 0.5 3.8 1.5 1.7 0.5 3.4 0.4 90 9 88 255 0 0 0 0 6.9 0 7.3 6.7 04/21/2005 03:00:00 3.4 0.6 5.3 1.9 3.4 0.6 4.9 1.5 2.6 0.7 4.2 0.4 99 11 103 255 0 0 0 0 6.8 0.1 7 6.7 04/21/2005 03:10:00 3.5 0.6 5.3 1.9 3.4 0.7 5.3 1.1 2.8 0.6 4.6 1.5 86 12 80 255 0 0 0 0 7 0 7.3 7 04/21/2005 03:20:00 3.5 0.8 5.7 1.9 3.4 0.8 6.1 1.9 2.6 0.7 5.3 1.1 100 11 94 255 0 0 0 0 7.1 0 7.3 7 04/21/2005 03:30:00 3.3 0.5 4.9 1.9 3.3 0.5 4.6 1.9 2.5 0.6 3.8 1.1 108 13 116 255 0 0 0 0 6.9 0 7 6.7 04/21/2005 03:40:00 2.7 0.7 4.2 1.1 2.6 0.7 4.6 1.1 1.9 0.8 4.2 0.4 102 12 112 255 0 0 0 0 6.7 0 7 6.7 04/21/2005 03:50:00 3.4 0.7 5.3 1.1 3.3 0.7 5.3 1.1 2.6 0.7 4.6 1.5 92 12 96 255 0 0 0 0 6.7 0 6.7 6.7 04/21/2005 04:00:00 3.5 0.6 5.3 1.9 3.5 0.6 5.3 1.9 2.7 0.7 4.6 1.1 100 11 107 255 0 0 0 0 6.7 0 6.7 6.7 04/21/2005 04:10:00 3.7 0.7 4.9 1.9 3.6 0.8 5.3 1.9 2.8 0.9 4.9 1.1 99 11 87 255 0 0 0 0 6.8 0 7 6.7 04/21/2005 04:20:00 3.5 0.8 5.7 1.9 3.4 0.9 5.7 1.5 2.7 0.8 4.9 1.5 111 13 106 255 0 0 0 0 6.7 0 7 6.7 04/21/2005 04:30:00 4 0.6 5.7 2.3 3.9 0.6 5.7 2.3 3.1 0.7 4.6 0.7 114 9 129 255 0 0 0 0 6.7 0 7 6.7 04/21/2005 04:40:00 3.1 0.5 4.2 0.7 3 0.5 4.2 0.7 2.6 0.5 3.8 0.7 102 10 121 255 0 0 0 0 6.7 0 6.7 6.5 04/21/2005 04:50:00 2.8 0.5 4.6 1.5 2.7 0.6 4.2 1.1 2.2 0.5 3.4 0.4 92 9 81 255 0 0 0 0 6.4 0.1 6.7 6.2 04/21/2005 05:00:00 2.8 0.4 3.8 1.9 2.7 0.4 3.4 1.5 2.3 0.4 3.4 1.1 97 9 88 255 0 0 0 0 6.1 0 6.2 5.7 04/21/2005 05:10:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.5 2.3 0.6 3.4 0.4 94 11 99 255 0 0 0 0 5.7 0 5.7 5.5 04/21/2005 05:20:00 4.1 0.8 6.5 2.6 4.1 0.8 6.5 2.3 3.3 0.9 6.1 1.5 88 11 86 255 0 0 0 0 5.4 0 5.7 5.5 04/21/2005 05:30:00 4.5 0.7 6.5 2.6 4.5 0.7 6.5 3 3.6 0.8 5.7 1.5 93 12 83 255 0 0 0 0 6.1 0.1 6.2 5.7 04/21/2005 05:40:00 5 0.8 6.8 3 4.9 0.8 7.2 3 4.2 0.9 6.8 2.3 85 12 92 255 0 0 0 0 6.4 0.1 6.7 6.2 04/21/2005 05:50:00 4.6 0.9 6.8 2.6 4.5 1 6.8 2.3 3.7 1 6.5 1.1 79 15 87 255 0 0 0 0 6.7 0 6.7 6.7 04/21/2005 06:00:00 4.6 1 7.6 2.3 4.6 1 7.6 1.9 3.9 0.8 6.1 1.5 73 15 85 255 0 0 0 0 6.7 0 6.7 6.7 04/21/2005 06:10:00 4.9 1 8 2.3 5 1 7.6 2.3 4.3 1.1 8 1.5 64 15 68 255 0 0 0 0 6.9 0 7 6.7 04/21/2005 06:20:00 5.2 1 8.4 2.3 5.1 1.1 8.8 2.3 4.5 1.1 7.2 1.9 67 14 60 255 0 0 0 0 7.1 0.1 7.5 7 04/21/2005 06:30:00 5 1 8 3 5 1 8 3 4.1 1 6.5 1.9 61 13 58 255 0 0 0 0 7.4 0 7.8 7.3 04/21/2005 06:40:00 4.6 1 7.2 2.3 4.7 1.1 8 2.3 4.1 1 7.2 1.9 61 15 40 255 0 0 0 0 8 0.1 8.3 7.5 04/21/2005 06:50:00 3.9 1 6.5 1.5 3.8 1.1 6.5 1.5 3.3 1 5.7 1.1 62 16 41 255 0 0 0 0 8.5 0.1 8.8 8.3 04/21/2005 07:00:00 3.4 0.9 5.7 1.5 3.3 0.9 5.3 1.1 2.9 0.9 4.9 1.1 77 17 78 255 0 0 0 0 8.3 0 8.5 8.3 04/21/2005 07:10:00 4.4 1.3 8 1.5 4.4 1.4 8 1.5 3.8 1.3 6.8 0.4 82 17 88 255 0 0 0 0 8.5 0 8.5 8.3 04/21/2005 07:20:00 5.3 1.3 8.8 2.3 5.3 1.3 8.8 2.3 4.6 1.2 7.6 1.9 70 17 55 255 0 0 0 0 8.4 0 8.5 8.3 04/21/2005 07:30:00 4.6 1.2 8 2.3 4.5 1.3 8.4 2.3 4 1.2 8 1.5 56 14 50 255 0 0 0 0 8.3 0 8.5 8.3 04/21/2005 07:40:00 5.4 1.4 9.5 1.5 5.4 1.5 9.9 1.9 4.7 1.5 9.1 1.9 56 15 47 255 0 0 0 0 8.4 0 8.5 8.3 04/21/2005 07:50:00 5.4 1.2 9.1 2.6 5.4 1.2 8.8 2.6 4.8 1.3 9.1 1.5 56 17 60 255 0 0 0 0 8.5 0 8.8 8.5 04/21/2005 08:00:00 5.5 1.2 7.6 2.6 5.5 1.2 8 2.3 4.9 1.2 7.6 1.9 47 14 37 255 0 0 0 0 8.6 0 8.8 8.5 04/21/2005 08:10:00 4.6 1.1 7.6 1.9 4.5 1.1 7.6 1.9 3.9 1.2 6.8 1.1 52 17 69 255 0 0 0 0 8.7 0 9 8.5 04/21/2005 08:20:00 5.7 1.1 8.4 2.6 5.6 1.1 8 2.6 5.1 1.1 7.6 2.3 57 15 45 255 0 0 0 0 9 0 9 8.8 04/21/2005 08:30:00 4.7 1.3 7.6 1.5 4.7 1.3 7.6 1.5 4.1 1.1 6.8 1.9 66 19 58 255 0 0 0 0 9.3 0.1 9.6 9 04/21/2005 08:40:00 4.7 1.3 7.2 1.9 4.7 1.3 7.2 1.5 4.1 1.3 6.8 0.7 67 18 60 255 0 0 0 0 9.7 0.1 9.8 9.3 04/21/2005 08:50:00 4.3 1 7.6 1.9 4.2 1 7.6 2.3 3.8 1 6.8 1.9 61 27 46 255 0 0 0 0 9.6 0 9.8 9.6 04/21/2005 09:00:00 4.4 0.9 7.2 2.3 4.3 0.9 6.8 2.3 4 0.9 5.7 1.5 57 15 30 255 0 0 0 0 9.9 0 10.1 9.8 04/21/2005 09:10:00 4.1 1 6.5 1.1 4.1 1 6.1 0.4 3.6 0.9 5.7 1.1 64 21 76 255 0 0 0 0 10.2 0.1 10.6 10.1 04/21/2005 09:20:00 4.6 1 7.2 1.9 4.6 1.1 6.8 1.5 4 1.2 7.2 1.1 56 17 46 255 0 0 0 0 10.6 0 10.9 10.6 04/21/2005 09:30:00 4.7 1.5 7.6 0.7 4.7 1.5 7.6 0.7 4.2 1.6 7.6 0.4 54 21 39 255 0 0 0 0 10.7 0 11.1 10.6 04/21/2005 09:40:00 5 1.3 8 1.9 5 1.3 7.6 2.3 4.3 1.1 7.2 1.5 61 21 62 255 0 0 0 0 11.9 0.6 12.7 11.1 04/21/2005 09:50:00 7 1.1 9.5 3.8 6.9 1.2 9.5 3.8 5.9 1.3 9.5 3 36 13 30 255 0 0 0 0 13 0.1 13.3 12.5 04/21/2005 10:00:00 5.8 1.1 8.4 3 5.8 1.1 8 3 5 1.2 8.8 2.3 43 20 42 255 0 0 0 0 13 0.1 13.5 12.7 04/21/2005 10:10:00 6.4 1.2 9.9 3 6.4 1.2 10.3 3 5.7 1.4 9.5 2.6 53 15 69 255 0 0 0 0 12.8 0 13.3 12.5 04/21/2005 10:20:00 5.4 1.5 9.1 1.1 5.4 1.5 9.1 1.5 4.8 1.4 8.8 1.1 54 18 53 255 0 0 0 0 13 0.1 13.5 12.7 04/21/2005 10:30:00 6.5 1.5 11.5 2.6 6.4 1.6 11.5 1.9 5.4 1.5 10.3 1.5 31 26 27 255 0 0 0 0 13.7 0.3 14.9 13 04/21/2005 10:40:00 7.4 1.2 10.7 4.2 7.4 1.2 11.1 4.6 6.3 1.4 10.3 3 15 12 12 255 0 0 0 0 14.5 0.2 15.2 14.1 04/21/2005 10:50:00 7.5 1.7 12.2 2.6 7.4 1.7 12.6 2.6 5.9 1.9 11.1 1.9 6 17 356 255 0 0 0 0 15 0 15.7 14.9 04/21/2005 11:00:00 8.7 2.2 14.5 3.4 8.7 2.3 14.9 3.4 6.8 2.2 11.5 2.3 6 13 356 255 0 0 0 0 14.9 0 15.5 14.6 04/21/2005 11:10:00 8.2 1.7 12.2 4.2 8.2 1.8 12.6 3.4 6.5 2 11.8 2.3 8 14 21 255 0 0 0 0 14.8 0 15.5 14.6 04/21/2005 11:20:00 8.8 1.5 13 4.2 8.8 1.5 13 4.9 7.2 1.7 11.5 3.4 11 13 19 255 0 0 0 0 14.6 0.1 15.2 14.4 04/21/2005 11:30:00 9.1 1.5 14.1 4.9 9.1 1.6 14.1 5.3 7.7 1.6 13 3 18 15 6 255 0 0 0 0 13.8 0.3 14.6 13.3 04/21/2005 11:40:00 9.5 1.5 14.5 6.1 9.5 1.6 14.1 4.9 7.9 1.8 13 3.8 12 11 32 255 0 0 0 0 13.7 0.1 14.1 13.3 04/21/2005 11:50:00 8.3 1.5 11.8 4.9 8.3 1.5 11.8 4.6 6.5 1.6 10.7 3 11 13 356 255 0 0 0 0 14.1 0.1 14.6 13.8 04/21/2005 12:00:00 7.9 2.1 13 3.8 7.9 2.2 13.3 3 6.1 2.1 11.8 2.3 9 15 9 255 0 0 0 0 14.7 0.2 15.5 14.4 04/21/2005 12:10:00 9.8 1.8 15.3 4.6 9.8 1.9 14.9 4.9 8.3 2 13.3 3.8 15 13 16 255 0 0 0 0 14.1 0.1 14.6 13.8 04/21/2005 12:20:00 8.9 1.5 12.2 3.8 8.8 1.6 12.2 3 7.6 1.7 11.8 2.6 16 12 9 255 0 0 0 0 14.3 0 14.9 14.1 04/21/2005 12:30:00 8.2 1.6 12.6 4.6 8.1 1.7 12.6 4.6 6.6 1.7 10.7 2.6 13 13 24 255 0 0 0 0 14.2 0.1 14.6 13.8 04/21/2005 12:40:00 7.4 1.5 11.1 4.2 7.3 1.5 11.1 3.8 6.1 1.6 9.5 2.6 19 15 11 255 0 0 0 0 14 0.1 14.6 13.8 04/21/2005 12:50:00 7.7 1.4 11.1 3.4 7.6 1.4 11.1 3.8 6.6 1.7 11.5 2.6 21 15 28 255 0 0 0 0 14 0.1 14.6 13.5 04/21/2005 13:00:00 7.9 1.3 11.1 3.4 7.9 1.3 11.5 3.8 6.8 1.5 10.7 2.6 21 13 12 255 0 0 0 0 13.9 0 14.6 13.8 04/21/2005 13:10:00 6.5 1.3 9.9 3.4 6.4 1.3 9.9 3 5.1 1.5 8.4 1.5 14 15 23 255 0 0 0 0 14.4 0 15.2 13.8 04/21/2005 13:20:00 7.7 1.6 11.5 4.6 7.6 1.7 11.5 4.2 6.1 1.8 10.7 2.3 11 18 32 255 0 0 0 0 14.6 0.1 15.2 14.4 04/21/2005 13:30:00 7.5 1.3 11.8 4.6 7.4 1.3 11.1 4.2 6.3 1.4 9.9 3 17 13 17 255 0 0 0 0 14.1 0.1 14.6 13.8 04/21/2005 13:40:00 8.1 1.6 12.2 3.8 8 1.6 12.2 3.4 6.6 2 11.8 1.9 14 13 19 255 0 0 0 0 13.6 0.1 14.4 13.3 04/21/2005 13:50:00 7.7 1.4 11.5 4.6 7.7 1.4 11.5 4.6 6.6 1.7 12.2 3 19 13 12 255 0 0 0 0 13.3 0 13.8 13 04/21/2005 14:00:00 8.1 1.8 11.8 3.8 8.1 1.9 11.8 3.4 7.2 2 12.6 3 29 13 37 255 0 0 0 0 13.2 0.2 13.8 12.7 04/21/2005 14:10:00 9.3 1.8 14.1 4.6 9.2 1.9 13.7 4.6 8 2 14.1 3 24 12 28 255 0 0 0 0 12.9 0.1 13.3 12.7 04/21/2005 14:20:00 9.2 1.8 14.9 4.9 9.2 1.9 14.5 4.6 7.6 2 13 3 19 14 6 255 0 0 0 0 12.8 0 13.3 12.7 04/21/2005 14:30:00 8.8 1.6 13.7 3.8 8.8 1.6 13.3 4.2 7.5 1.7 11.5 3.4 19 12 16 255 0 0 0 0 12.7 0 13 12.7 04/21/2005 14:40:00 10.3 1.7 15.6 6.1 10.2 1.7 15.6 6.5 8.7 1.9 14.1 3 21 13 32 255 0 0 0 0 12.5 0 12.7 12.2 04/21/2005 14:50:00 10 2.2 15.3 5.3 10 2.3 14.9 4.9 8.6 2.5 14.1 3.4 24 13 21 255 0 0 0 0 12.3 0 12.7 12.2 04/21/2005 15:00:00 9.9 2 14.9 5.7 9.9 2 14.9 5.7 8.1 2.1 13.3 3.8 23 12 19 255 0 0 0 0 12.3 0 12.7 12.2 04/21/2005 15:10:00 9.2 1.6 12.2 5.3 9.1 1.7 12.6 5.3 7.9 1.7 12.2 4.2 26 13 31 255 0 0 0 0 12.2 0 12.7 11.9 04/21/2005 15:20:00 9.8 2.1 14.5 4.6 9.7 2.1 14.9 4.9 8.4 1.9 14.9 4.2 27 13 43 255 0 0 0 0 12.1 0 12.5 11.9 04/21/2005 15:30:00 9 1.9 14.9 4.9 9 1.9 14.9 4.6 7.6 1.9 13 3.8 27 17 59 255 0 0 0 0 11.8 0 11.9 11.7 04/21/2005 15:40:00 9.9 2.7 17.9 3.8 9.8 2.8 17.9 4.2 8.2 2.8 16.1 2.3 29 15 19 255 0 0 0 0 11.7 0 12.2 11.7 04/21/2005 15:50:00 10.8 2.3 16.4 5.7 10.7 2.3 16.4 5.7 9.2 2.3 14.1 4.2 30 12 23 255 0 0 0 0 11.7 0 11.9 11.7 04/21/2005 16:00:00 11.3 2.3 17.6 6.1 11.2 2.3 17.6 6.5 9.8 2.3 15.6 5.3 30 12 11 255 0 0 0 0 11.6 0 11.7 11.4 04/21/2005 16:10:00 11.2 2.3 16.1 6.1 11.2 2.3 16.1 6.1 9.4 2.4 14.5 4.2 25 15 20 255 0 0 0 0 11.3 0 11.7 11.1 04/21/2005 16:20:00 10.6 2.2 16.1 5.7 10.5 2.3 16.1 5.3 9 2.2 15.3 4.9 24 13 11 255 0 0 0 0 11 0 11.4 10.9 04/21/2005 16:30:00 9.8 2.2 15.3 4.9 9.8 2.2 15.6 4.9 8.4 2.3 15.6 3 31 17 35 255 0 0 0 0 10.7 0 10.9 10.6 04/21/2005 16:40:00 8.9 2.2 16.8 3.8 8.9 2.3 16.8 3 7.6 2.4 15.3 0.7 26 15 46 255 0 0 0 0 10.6 0 10.6 10.6 04/21/2005 16:50:00 8.3 2 13 3.4 8.3 2 12.6 3.8 7.2 1.8 11.8 2.3 36 14 32 255 0 0 0 0 10.6 0 10.6 10.6 04/21/2005 17:00:00 9.1 2.3 14.9 4.6 9 2.3 14.9 4.2 7.7 2.1 13 3 30 12 19 255 0 0 0 0 10.5 0 10.6 10.3 04/21/2005 17:10:00 9.3 2.2 16.4 5.3 9.3 2.2 16.4 5.3 8.1 2.2 14.9 3.4 39 13 30 255 0 0 0 0 10.3 0.1 10.6 10.3 04/21/2005 17:20:00 8 1.9 13.3 4.2 8 1.8 13 4.2 7.1 1.9 12.6 3.4 37 13 31 255 0 0 0 0 10.2 0 10.3 10.1 04/21/2005 17:30:00 9.4 2.1 14.5 4.9 9.3 2.1 14.1 4.6 8.3 2.1 14.9 3.8 41 14 42 255 0 0 0 0 10 0 10.1 9.8 04/21/2005 17:40:00 10 2.2 14.9 4.9 10 2.3 15.3 4.6 8.9 2.3 14.1 3.8 39 15 32 255 0 0 0 0 9.7 0 9.8 9.6 04/21/2005 17:50:00 9 1.8 14.1 4.9 8.9 1.9 14.1 5.3 7.8 2 13.3 3.4 41 17 41 255 0 0 0 0 9.5 0 9.6 9.6 04/21/2005 18:00:00 9.2 2.1 15.6 4.6 9.1 2.1 15.3 4.6 7.6 2.1 13 1.9 47 17 57 255 0 0 0 0 9.5 0 9.6 9.3 04/21/2005 18:10:00 10.7 2.6 16.1 4.6 10.7 2.6 16.1 4.2 9.3 2.5 15.3 3.4 43 14 39 255 0 0 0 0 9.4 0 9.6 9.3 04/21/2005 18:20:00 10.9 2.2 17.2 4.9 10.8 2.2 17.2 4.9 9.4 2.4 16.1 4.2 41 15 24 255 0 0 0 0 9.4 0 9.6 9.3 04/21/2005 18:30:00 10 2.8 21 4.2 10 2.8 21.4 4.2 8.5 2.8 19.1 2.3 37 17 45 255 0 0 0 0 9.4 0 9.6 9.3 04/21/2005 18:40:00 12 2.7 19.5 5.7 12 2.7 19.5 5.7 10.3 2.6 17.2 4.9 37 15 34 255 0 0 0 0 9.5 0 9.6 9.3 04/21/2005 18:50:00 11.3 2.3 16.4 6.1 11.3 2.3 16.4 5.7 9.7 2.7 17.6 4.6 37 17 43 255 0 0 0 0 9.5 0 9.6 9.6 04/21/2005 19:00:00 11.3 2.7 19.9 4.6 11.3 2.8 19.9 4.6 10 2.7 19.1 4.2 37 15 29 255 0 0 0 0 9.5 0 9.6 9.3 04/21/2005 19:10:00 12.2 2.6 21 5.7 12.1 2.6 20.2 6.1 10.7 2.5 19.1 4.9 40 15 28 255 0 0 0 0 9.4 0 9.6 9.3 04/21/2005 19:20:00 13.6 2.8 21 6.5 13.5 2.8 21 6.5 11.8 2.7 19.5 5.3 45 13 55 255 0 0 0 0 9.1 0 9.3 9 04/21/2005 19:30:00 11.4 2.3 17.6 4.6 11.4 2.3 17.6 4.9 10 2.3 17.9 4.9 42 15 30 255 0 0 0 0 8.7 0.1 9 8.5 04/21/2005 19:40:00 11.8 2.9 19.1 6.1 11.8 2.8 19.1 5.7 10.3 2.9 19.1 3.8 45 15 29 255 0 0 0 0 8.5 0 8.8 8.5 04/21/2005 19:50:00 14.1 3.1 21.8 5.3 14 3.2 21.4 4.9 12.2 2.8 19.9 6.1 37 12 37 255 0 0 0 0 8.5 0 8.5 8.5 04/21/2005 20:00:00 14.7 3.2 24 6.8 14.6 3.2 24.4 6.8 12.8 3.2 20.2 6.1 40 13 40 255 0 0 0 0 8.2 0 8.5 8 04/21/2005 20:10:00 13.9 3.2 25.2 8.4 13.8 3.2 25.6 7.6 11.8 3.2 22.1 4.9 28 13 21 255 0 0 0 0 8 0 8.3 8 04/21/2005 20:20:00 15.1 2.9 23.3 9.1 15 2.9 22.9 8.4 13.2 3.1 22.9 6.5 34 13 46 255 0 0 0 0 8 0 8.3 7.8 04/21/2005 20:30:00 14.8 2.3 21 9.1 14.7 2.4 21 9.5 12.6 2.5 19.1 6.1 31 14 6 255 0 0 0 0 7.9 0 8 7.8 04/21/2005 20:40:00 15 2.6 22.9 8 14.9 2.7 22.9 7.2 12.9 2.8 20.2 6.8 30 14 18 255 0 0 0 0 7.8 0 8 7.8 04/21/2005 20:50:00 14.3 2.5 22.9 7.2 14.3 2.7 22.9 8.4 12.3 2.7 20.6 5.7 29 13 30 255 0 0 0 0 8 0 8.3 7.8 04/21/2005 21:00:00 15.2 2.8 21.8 8.4 15.2 2.8 22.6 8.4 13.3 2.9 22.1 6.5 32 13 28 255 0 0 0 0 7.9 0 8 7.8 04/21/2005 21:10:00 15.6 2.9 23.7 8.8 15.5 2.9 23.7 8.8 13.2 3.1 23.3 7.2 31 12 40 255 0 0 0 0 8 0 8.3 7.8 04/21/2005 21:20:00 15.8 2.6 23.7 9.9 15.8 2.7 23.3 9.5 13.7 2.8 22.1 7.2 31 12 32 255 0 0 0 0 8.2 0 8.3 8 04/21/2005 21:30:00 15.6 2.9 22.9 9.9 15.6 2.9 22.9 9.5 13.5 2.8 20.6 8 32 11 20 255 0 0 0 0 8.3 0 8.5 8.3 04/21/2005 21:40:00 16 2.9 22.1 7.6 16 2.9 22.6 6.5 14.2 2.9 21.4 6.5 30 12 44 255 0 0 0 0 8.4 0 8.5 8.3 04/21/2005 21:50:00 15.4 2.6 22.1 9.9 15.4 2.7 22.9 9.1 13.1 2.7 20.6 7.2 28 13 27 255 0 0 0 0 8.5 0 8.8 8.5 04/21/2005 22:00:00 15 3.1 22.6 8.4 14.9 3.1 22.9 8.4 12.7 2.9 19.9 6.1 33 13 10 255 0 0 0 0 8.8 0 9 8.5 04/21/2005 22:10:00 14.5 2.7 21 8.4 14.4 2.7 20.6 7.6 12.7 2.7 20.6 5.7 32 13 26 255 0 0 0 0 8.9 0 9 9 04/21/2005 22:20:00 15.9 3.1 26 8.8 15.7 3.2 25.6 9.1 13.7 3.2 23.7 6.5 35 13 22 255 0 0 0 0 9.1 0 9.3 9 04/21/2005 22:30:00 14.7 2.7 21.8 8 14.6 2.7 21.8 7.2 12.7 2.9 22.1 6.1 31 12 20 255 0 0 0 0 9.1 0 9.3 9 04/21/2005 22:40:00 13.4 2.8 22.6 5.7 13.4 2.8 22.9 5.3 11.6 2.9 19.1 6.1 33 14 40 255 0 0 0 0 9.1 0 9.3 9 04/21/2005 22:50:00 13.9 2.4 20.2 7.2 13.9 2.4 20.6 6.8 12.6 2.5 18.7 4.9 34 14 29 255 0 0 0 0 9.2 0 9.3 9 04/21/2005 23:00:00 14.7 2.6 24 8 14.7 2.7 23.3 8.4 13 2.7 21.4 6.5 35 12 22 255 0 0 0 0 9.4 0 9.6 9.3 04/21/2005 23:10:00 14.5 2.6 21.8 8.8 14.4 2.7 21.8 8.8 12.4 2.8 21 6.5 32 12 32 255 0 0 0 0 9.4 0 9.6 9.3 04/21/2005 23:20:00 13.6 2.3 19.9 7.2 13.5 2.4 20.6 8 11.9 2.7 18.7 4.6 30 13 35 255 0 0 0 0 9.3 0 9.6 9.3 04/21/2005 23:30:00 13.7 2.6 21.4 8 13.5 2.7 21.4 7.6 11.7 2.9 21.4 6.1 32 13 46 255 0 0 0 0 9.5 0 9.6 9.3 04/21/2005 23:40:00 13.2 2.4 18.3 7.6 13.1 2.5 18.7 7.6 11.2 2.5 17.9 5.7 32 15 48 255 0 0 0 0 9.7 0 9.8 9.6 04/21/2005 23:50:00 13.2 2.4 18.7 8 13.2 2.4 18.7 7.6 11.7 2.4 17.6 6.8 31 12 40 255 0 0 0 0 10 0 10.1 9.8 04/22/2005 00:00:00 13.4 2.6 22.1 8 13.3 2.7 22.1 7.6 11.4 2.7 19.9 5.3 30 15 35 255 0 0 0 0 10 0 10.1 9.8 04/22/2005 00:10:00 14 2.8 21.4 8 14 2.9 21 7.6 12.1 2.8 19.9 5.7 32 13 30 255 0 0 0 0 9.9 0 10.1 9.8 04/22/2005 00:20:00 14.5 2.9 21.8 7.6 14.5 2.9 21.8 8 12.5 3.1 21.4 6.5 32 12 53 255 0 0 0 0 9.6 0.1 9.8 9.6 04/22/2005 00:30:00 14.4 2.7 20.6 9.1 14.4 2.8 20.6 8.8 12.6 2.9 19.5 5.7 33 12 32 255 0 0 0 0 9.5 0 9.6 9.6 04/22/2005 00:40:00 15.1 2.8 23.3 9.1 15.1 2.8 22.9 8.8 13 3.1 22.6 7.2 34 13 30 255 0 0 0 0 9.6 0 9.6 9.6 04/22/2005 00:50:00 15.7 2.7 22.9 9.9 15.7 2.8 22.9 9.9 13.5 3.1 21.8 6.8 33 13 42 255 0 0 0 0 9.7 0 9.8 9.6 04/22/2005 01:00:00 14.2 2.9 21.4 8 14.1 2.9 21.8 7.2 12.4 2.9 19.5 5.3 32 12 34 255 0 0 0 0 9.6 0 9.8 9.6 04/22/2005 01:10:00 13.4 2.3 18.7 7.2 13.4 2.3 19.1 6.8 11.7 2.4 17.9 6.5 33 15 34 255 0 0 0 0 9.5 0 9.6 9.6 04/22/2005 01:20:00 14.8 3.1 21.8 7.2 14.7 3.2 21.8 6.8 12.6 3.1 20.6 5.3 32 13 24 255 0 0 0 0 9.6 0 9.6 9.3 04/22/2005 01:30:00 16.2 2.8 22.9 9.9 16.1 2.8 22.9 9.5 14.1 2.7 21.4 8.8 33 12 39 255 0 0 0 0 9.7 0 9.8 9.6 04/22/2005 01:40:00 15.4 2.6 23.3 8.8 15.4 2.6 23.3 8.8 13.5 2.8 21.4 7.2 32 13 29 255 0 0 0 0 9.6 0 9.8 9.3 04/22/2005 01:50:00 15.1 2.7 21.8 8 15.1 2.8 21.8 7.6 13.4 2.8 21 7.2 33 13 44 255 0 0 0 0 9.5 0 9.6 9.3 04/22/2005 02:00:00 14.6 2.9 23.7 8.8 14.5 3.1 22.9 8.4 12.4 2.9 21.8 6.8 28 13 28 255 0 0 0 0 9.4 0 9.6 9.3 04/22/2005 02:10:00 14.3 3.1 24 6.5 14.3 3.2 24.8 6.8 12.3 3.2 22.9 6.1 31 12 27 255 0 0 0 0 9.3 0 9.6 9 04/22/2005 02:20:00 13.1 2.5 21.8 7.2 13 2.5 22.1 6.8 11 2.7 22.1 4.6 29 14 29 255 0 0 0 0 9.1 0 9.3 9 04/22/2005 02:30:00 13.8 3.3 22.6 6.5 13.8 3.3 22.6 6.8 12.1 3.5 22.1 3.8 27 15 26 255 0 0 0 0 9.2 0 9.3 9 04/22/2005 02:40:00 14.1 2.7 20.2 6.1 14.2 2.6 20.2 6.8 12 2.8 17.9 4.9 27 14 39 255 0 0 0 0 9.4 0 9.6 9.3 04/22/2005 02:50:00 13.8 2.8 21.4 7.2 13.8 2.9 21.8 6.8 12.2 2.9 21 5.3 30 12 37 255 0 0 0 0 9.2 0 9.3 9.3 04/22/2005 03:00:00 13.8 2.5 22.1 7.2 13.7 2.5 21.4 7.2 12.1 2.8 19.1 3.8 31 12 357 255 0 0 0 0 9.1 0 9.3 9 04/22/2005 03:10:00 12.7 2.8 20.2 6.1 12.6 2.8 20.6 5.7 10.8 2.9 19.5 4.9 31 15 21 255 0 0 0 0 8.9 0 9 9 04/22/2005 03:20:00 13.6 2.9 21 5.3 13.6 3.1 22.1 4.9 11.8 2.9 18.7 4.2 31 13 21 255 0 0 0 0 8.9 0 9 9 04/22/2005 03:30:00 12.8 2.8 20.2 6.1 12.8 2.8 20.6 5.3 11 2.9 19.1 4.9 28 13 27 255 0 0 0 0 8.9 0 9 8.8 04/22/2005 03:40:00 12.4 2.5 18.3 7.2 12.4 2.6 18.3 6.8 10.6 2.8 18.3 4.2 25 14 35 255 0 0 0 0 8.7 0 9 8.8 04/22/2005 03:50:00 12.4 2.3 17.6 6.8 12.3 2.3 17.9 6.8 10.6 2.4 17.9 4.9 28 13 40 255 0 0 0 0 8.7 0 8.8 8.8 04/22/2005 04:00:00 10.7 2.5 18.7 5.3 10.7 2.5 18.7 5.3 9 2.5 17.6 4.6 21 13 69 255 0 0 0 0 8.7 0 8.8 8.8 04/22/2005 04:10:00 10.4 2.7 17.9 4.6 10.4 2.8 17.6 4.6 8.9 2.8 16.1 2.6 26 14 12 255 0 0 0 0 8.6 0 8.8 8.5 04/22/2005 04:20:00 12.3 2.3 17.2 6.5 12.2 2.4 17.6 6.8 10.6 2.4 17.2 4.9 29 13 36 255 0 0 0 0 8.7 0 8.8 8.5 04/22/2005 04:30:00 12.7 2.7 19.1 3.8 12.7 2.7 19.1 3.8 10.6 2.7 17.6 3.8 27 13 41 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 04:40:00 13.3 2.5 20.2 6.5 13.2 2.5 20.6 6.5 11.6 2.6 18.7 5.7 26 12 27 255 0 0 0 0 8.4 0 8.5 8.5 04/22/2005 04:50:00 12.3 2.7 19.1 4.2 12.3 2.8 19.9 3.8 10.6 2.8 17.6 3.4 31 14 18 255 0 0 0 0 8.4 0 8.5 8.3 04/22/2005 05:00:00 12.2 2.6 19.1 5.3 12.1 2.7 19.5 4.9 10.3 2.8 16.8 3.4 26 13 33 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 05:10:00 11 3.1 19.5 4.6 10.9 3.1 19.9 4.6 9.2 2.7 16.4 4.2 25 15 36 255 0 0 0 0 8.4 0 8.5 8.5 04/22/2005 05:20:00 11.3 2.4 16.8 6.1 11.3 2.5 17.2 6.5 9.3 2.4 15.6 4.6 22 14 12 255 0 0 0 0 8.4 0 8.5 8.3 04/22/2005 05:30:00 10.8 2.4 17.2 6.1 10.7 2.4 16.8 5.7 9.2 2.5 16.1 3.8 29 13 27 255 0 0 0 0 8.5 0 8.5 8.5 04/22/2005 05:40:00 10.9 2.5 19.1 5.3 10.8 2.5 18.3 5.3 9.3 2.5 16.1 4.2 30 15 22 255 0 0 0 0 8.6 0 8.8 8.5 04/22/2005 05:50:00 10.4 2.3 16.1 5.3 10.3 2.3 15.6 4.6 9 2.4 14.9 3.8 27 15 358 255 0 0 0 0 8.8 0 9 8.8 04/22/2005 06:00:00 9.9 1.7 15.6 5.7 9.9 1.7 15.3 5.7 8.7 1.8 13.3 4.6 23 13 8 255 0 0 0 0 9 0 9 9 04/22/2005 06:10:00 10.5 2.4 16.4 5.3 10.4 2.4 16.8 4.9 8.7 2.2 15.3 4.2 25 15 43 255 0 0 0 0 9.1 0 9.3 9 04/22/2005 06:20:00 10.9 2.1 16.4 5.7 10.9 2.1 16.4 5.7 9.3 2.1 14.9 4.9 24 13 21 255 0 0 0 0 9.4 0 9.6 9.3 04/22/2005 06:30:00 11 2.3 19.9 5.3 10.9 2.3 19.1 5.3 9.2 2.2 16.4 4.6 24 13 20 255 0 0 0 0 9.6 0 9.8 9.6 04/22/2005 06:40:00 10.6 2.4 17.2 5.7 10.5 2.4 17.6 5.7 8.9 2.3 15.3 4.2 27 16 32 255 0 0 0 0 9.8 0 9.8 9.6 04/22/2005 06:50:00 12 2.9 19.5 5.3 12 2.9 19.1 4.9 10.4 3.1 17.6 2.6 25 15 32 255 0 0 0 0 9.9 0 10.1 9.8 04/22/2005 07:00:00 12.6 2.7 20.2 8.4 12.5 2.7 20.2 8.4 10.6 2.7 17.6 5.3 25 11 21 255 0 0 0 0 9.9 0 10.1 9.8 04/22/2005 07:10:00 11 2.1 16.8 5.3 10.9 2.2 16.4 5.3 9.3 2.4 16.4 2.6 24 13 37 255 0 0 0 0 9.8 0 9.8 9.8 04/22/2005 07:20:00 11.6 2.6 17.9 6.5 11.5 2.6 17.9 6.1 10 2.6 17.2 4.9 26 12 22 255 0 0 0 0 10 0 10.1 9.8 04/22/2005 07:30:00 12 1.7 17.9 7.6 12 1.7 17.6 7.6 10.3 1.9 16.4 4.9 24 12 17 255 0 0 0 0 10.1 0 10.3 9.8 04/22/2005 07:40:00 11.2 2.4 17.6 4.6 11.1 2.4 17.6 3.8 9.7 2.5 16.1 3.8 24 13 23 255 0 0 0 0 10.3 0 10.3 10.3 04/22/2005 07:50:00 10 2.1 17.2 5.3 10 2.2 17.6 5.7 8.4 2.1 15.6 3.8 21 13 13 255 0 0 0 0 10.3 0 10.3 10.3 04/22/2005 08:00:00 11.3 2.5 18.7 6.5 11.2 2.5 19.1 6.1 9.7 2.7 16.1 3.8 23 12 35 255 0 0 0 0 10.3 0 10.6 10.3 04/22/2005 08:10:00 11.8 2.9 19.5 4.6 11.7 2.9 19.5 4.6 9.8 2.9 17.6 4.2 21 14 22 255 0 0 0 0 10.2 0 10.3 10.3 04/22/2005 08:20:00 13 2.6 20.2 8 13 2.6 20.6 7.6 11 2.7 17.6 5.3 22 11 19 255 0 0 0 0 10.2 0 10.3 10.1 04/22/2005 08:30:00 12.3 2.3 18.3 7.2 12.3 2.3 18.7 6.8 10.5 2.5 16.8 4.6 20 13 24 255 0 0 0 0 10 0 10.1 9.8 04/22/2005 08:40:00 13 2.5 18.7 5.7 13 2.5 18.7 6.1 11.2 2.7 17.9 5.7 22 13 31 255 0 0 0 0 10.1 0 10.3 10.1 04/22/2005 08:50:00 13 2.1 19.1 8.4 12.9 2.2 19.5 7.2 10.8 2.4 18.7 5.7 21 12 11 255 0 0 0 0 10.2 0 10.3 10.1 04/22/2005 09:00:00 13.7 2.7 22.1 7.2 13.7 2.8 22.6 6.8 11.9 2.9 19.9 4.6 23 12 18 255 0 0 0 0 10.1 0 10.3 10.1 04/22/2005 09:10:00 13.8 2.4 20.6 7.6 13.8 2.5 21 7.2 11.8 2.6 19.5 6.5 23 13 27 255 0 0 0 0 10.1 0 10.3 10.1 04/22/2005 09:20:00 13.8 2.9 22.9 7.6 13.8 3.1 22.9 6.5 11.8 2.9 19.9 5.3 24 12 15 255 0 0 0 0 10.2 0 10.3 10.3 04/22/2005 09:30:00 14 2.5 22.1 9.1 14 2.5 22.9 8.8 11.7 2.7 19.5 6.8 21 12 12 255 0 0 0 0 10.3 0 10.6 10.3 04/22/2005 09:40:00 12.6 2 18.3 8.4 12.5 2.1 19.1 8.4 10.8 2.4 17.9 5.3 23 13 16 255 0 0 0 0 10.4 0 10.6 10.3 04/22/2005 09:50:00 13 2.6 19.5 5.7 12.9 2.6 19.9 6.1 10.8 2.7 19.1 3.8 24 13 30 255 0 0 0 0 10.4 0 10.6 10.3 04/22/2005 10:00:00 13.4 2.4 19.1 7.6 13.3 2.4 19.1 7.2 11.3 2.6 17.9 4.9 22 13 10 255 0 0 0 0 10.5 0 10.6 10.3 04/22/2005 10:10:00 12.8 2.7 19.5 5.7 12.7 2.8 19.1 5.7 10.8 3.1 19.9 3 21 14 7 255 0 0 0 0 10.5 0 10.6 10.6 04/22/2005 10:20:00 12.7 2.9 19.1 6.8 12.7 2.9 19.1 6.1 11 2.7 17.6 3.4 20 11 33 255 0 0 0 0 10.6 0 10.6 10.6 04/22/2005 10:30:00 13.3 3.1 19.1 4.9 13.3 3.1 19.1 5.7 11.1 3.2 17.9 3.4 19 15 19 255 0 0 0 0 10.6 0 10.9 10.6 04/22/2005 10:40:00 13 3.1 21.4 6.5 13 3.1 21.4 6.1 10.8 3.1 18.7 3.8 20 14 21 255 0 0 0 0 10.7 0 10.9 10.6 04/22/2005 10:50:00 13.1 2.6 20.6 6.8 13.1 2.6 20.2 7.2 11.3 2.7 19.9 6.1 26 12 23 255 0 0 0 0 10.4 0 10.6 10.3 04/22/2005 11:00:00 13.9 2.6 20.2 8.8 13.8 2.6 21.4 8.8 11.7 2.8 19.1 6.1 26 13 12 255 0 0 0 0 10.2 0 10.3 10.1 04/22/2005 11:10:00 14.7 2.9 21.4 8 14.7 2.9 21.4 8 12.7 3.2 22.1 4.6 27 14 35 255 0 0 0 0 10.3 0.1 10.6 10.1 04/22/2005 11:20:00 14 2.5 20.6 7.2 13.9 2.6 21.4 6.5 11.9 2.7 18.7 5.3 22 13 25 255 0 0 0 0 10.3 0.1 10.6 10.3 04/22/2005 11:30:00 14.6 3.2 22.6 8 14.7 3.2 22.6 8 12.3 3.3 21 4.6 21 15 37 255 0 0 0 0 11.1 0.3 11.7 10.6 04/22/2005 11:40:00 14.3 2.9 21.8 6.5 14.3 3.1 22.1 6.8 12 3.2 21.4 3.8 23 13 12 255 0 0 0 0 11 0 11.4 10.9 04/22/2005 11:50:00 14.6 3.1 23.3 6.8 14.6 3.1 23.3 6.8 12.2 3.2 22.6 4.9 21 13 11 255 0 0 0 0 10.7 0 10.9 10.6 04/22/2005 12:00:00 13.1 2.5 19.1 6.5 13.1 2.6 19.5 6.1 11.4 2.6 17.9 3.8 20 12 26 255 0 0 0 0 10.9 0 11.1 10.6 04/22/2005 12:10:00 12.1 2.3 18.3 5.3 12.1 2.4 18.7 5.7 9.9 2.5 18.3 4.6 19 13 13 255 0 0 0 0 11.5 0.1 11.7 11.1 04/22/2005 12:20:00 12.1 2.6 17.9 6.1 12.1 2.6 17.9 5.7 10.3 2.7 16.1 3.8 18 11 10 255 0 0 0 0 11.6 0.1 11.9 11.1 04/22/2005 12:30:00 11 2.8 19.5 5.3 10.9 2.9 19.9 4.9 9.1 2.9 16.8 3 19 13 17 255 0 0 0 0 11.2 0 11.4 11.1 04/22/2005 12:40:00 10.6 2 15.6 5.7 10.6 2 16.1 6.1 8.9 2.1 15.3 3.8 18 12 9 255 0 0 0 0 11.3 0 11.4 11.1 04/22/2005 12:50:00 10.1 1.7 15.6 6.5 10.1 1.7 15.3 6.1 8.7 1.7 13 4.2 20 12 15 255 0 0 0 0 11.7 0 11.7 11.4 04/22/2005 13:00:00 9.8 1.9 14.5 5.3 9.7 1.9 14.5 4.9 8 1.8 13 3.4 20 12 13 255 0 0 0 0 12.3 0.3 12.7 11.7 04/22/2005 13:10:00 10.7 2.3 15.6 4.2 10.6 2.3 15.6 4.2 9.1 2.4 14.9 3.4 25 14 16 255 0 0 0 0 12.4 0.2 12.7 11.9 04/22/2005 13:20:00 9 1.9 16.4 5.7 8.9 2 17.2 5.3 7.6 2 14.5 3 30 16 24 255 0 0 0 0 12.1 0 12.2 11.9 04/22/2005 13:30:00 11 2.3 17.2 4.9 11 2.3 17.2 4.9 9.6 2.3 14.9 4.6 23 11 9 255 0 0 0 0 12.1 0 12.2 11.9 04/22/2005 13:40:00 10.6 2.2 17.2 3.8 10.6 2.2 17.6 3.4 8.8 2.2 15.3 3.4 20 13 23 255 0 0 0 0 12.3 0.1 12.5 11.9 04/22/2005 13:50:00 10.3 2.1 15.3 3.8 10.3 2.1 15.3 4.6 8.5 2.3 14.9 2.3 23 13 1 255 0 0 0 0 12.5 0 12.7 12.5 04/22/2005 14:00:00 10.7 1.7 14.5 5.7 10.6 1.8 14.5 6.1 9.1 1.9 13.7 4.6 18 11 15 255 0 0 0 0 12.6 0 12.7 12.5 04/22/2005 14:10:00 10.7 1.7 15.3 6.5 10.7 1.8 15.6 6.1 9.2 2.2 15.3 4.6 21 12 17 255 0 0 0 0 12.5 0 12.5 12.5 04/22/2005 14:20:00 9.8 2.2 14.9 3.8 9.8 2.2 15.3 3.8 8.3 2.4 14.9 1.9 19 13 24 255 0 0 0 0 12.7 0 12.7 12.5 04/22/2005 14:30:00 9.8 1.7 14.1 6.1 9.8 1.7 14.1 6.5 8.1 2 13.7 4.2 19 14 20 255 0 0 0 0 12.9 0.1 13.5 12.7 04/22/2005 14:40:00 10.4 2.9 15.6 4.2 10.3 2.9 15.6 3.8 8.5 2.8 14.9 3 16 15 15 255 0 0 0 0 13.5 0.1 14.4 13 04/22/2005 14:50:00 8.5 2.1 13.7 3 8.4 2.2 14.1 3 7 2.3 13.7 1.9 16 16 26 255 0 0 0 0 13.9 0 14.4 13.8 04/22/2005 15:00:00 8.4 2.1 14.1 3.8 8.4 2.1 13.7 3.8 6.8 2.2 13 2.6 16 17 32 255 0 0 0 0 13.7 0 14.4 13.5 04/22/2005 15:10:00 10.4 2.4 16.8 5.3 10.4 2.5 16.4 4.9 8.6 2.5 16.1 3.4 16 17 36 255 0 0 0 0 13.5 0.2 14.1 13 04/22/2005 15:20:00 10.3 2.6 16.1 4.6 10.3 2.6 16.4 4.9 9 2.7 14.9 2.6 21 13 20 255 0 0 0 0 12.7 0.1 13 12.5 04/22/2005 15:30:00 10.2 2.1 16.4 3.8 10.2 2.2 15.3 4.2 8.8 2.2 14.9 3 19 12 37 255 0 0 0 0 12.3 0.1 12.5 11.9 04/22/2005 15:40:00 9.6 1.9 14.9 5.3 9.6 1.9 14.5 5.3 8.1 2 12.6 3.4 20 13 25 255 0 0 0 0 11.9 0 12.5 11.9 04/22/2005 15:50:00 10.7 1.9 16.1 6.5 10.7 1.9 15.6 5.3 9 2 14.9 3.4 20 11 10 255 0 0 0 0 11.7 0 12.2 11.7 04/22/2005 16:00:00 9.9 2 14.5 4.9 9.9 2 14.9 4.9 8.3 2.3 13.7 3.4 18 15 34 255 0 0 0 0 11.7 0 11.9 11.7 04/22/2005 16:10:00 10.4 2.7 17.2 4.6 10.3 2.7 17.2 4.2 8.5 2.8 16.4 3 20 15 32 255 0 0 0 0 11.7 0 11.7 11.7 04/22/2005 16:20:00 12.4 1.7 17.6 6.1 12.4 1.8 17.6 5.3 10.7 2.3 17.2 4.9 19 12 17 255 0 0 0 0 11.5 0 11.7 11.4 04/22/2005 16:30:00 11.8 2.3 17.9 6.5 11.8 2.4 17.6 6.1 10 2.3 16.1 4.9 20 12 26 255 0 0 0 0 11.3 0 11.4 11.1 04/22/2005 16:40:00 11.1 2.6 15.6 4.2 11.1 2.6 16.1 3.8 9.3 2.7 14.9 2.3 18 12 21 255 0 0 0 0 11.1 0 11.1 10.9 04/22/2005 16:50:00 11.1 3.3 18.7 3.8 11.1 3.3 18.7 3 9.5 3.1 17.9 3.8 18 12 18 255 0 0 0 0 10.9 0 11.1 10.9 04/22/2005 17:00:00 10.5 2 17.2 6.1 10.4 2 16.8 5.3 8.5 2 13.7 3.8 17 15 3 255 0 0 0 0 10.7 0 10.9 10.6 04/22/2005 17:10:00 10.9 2.6 17.6 5.3 10.9 2.6 18.3 5.7 9.4 2.5 16.8 4.2 21 13 14 255 0 0 0 0 10.6 0 10.9 10.6 04/22/2005 17:20:00 10 2.9 16.4 3.4 10 2.9 16.4 3.4 8.1 2.7 15.6 2.3 17 12 20 255 0 0 0 0 10.5 0 10.6 10.3 04/22/2005 17:30:00 11.3 2.2 17.6 5.7 11.3 2.2 17.6 6.1 9.7 2.2 14.1 4.2 23 10 26 255 0 0 0 0 10.3 0 10.6 10.3 04/22/2005 17:40:00 10 1.8 15.6 6.1 10 1.9 16.1 6.1 8.5 1.8 13.7 4.6 24 12 8 255 0 0 0 0 10.2 0 10.3 10.1 04/22/2005 17:50:00 9.4 2.5 16.8 4.2 9.4 2.5 16.8 3.8 7.7 2.5 16.1 2.6 17 15 6 255 0 0 0 0 10 0 10.3 9.8 04/22/2005 18:00:00 10.8 2.6 17.9 4.6 10.7 2.6 17.9 4.6 9.3 2.5 17.2 4.2 26 14 28 255 0 0 0 0 9.6 0 9.8 9.3 04/22/2005 18:10:00 8.8 2.4 16.4 3.4 8.8 2.4 16.4 3 7.2 2.5 15.6 2.6 22 17 38 255 0 0 0 0 9.1 0 9.3 9 04/22/2005 18:20:00 8.6 2.3 14.5 3.8 8.6 2.3 14.1 4.2 7.1 2.2 13 2.3 17 12 25 255 0 0 0 0 9 0 9.3 9 04/22/2005 18:30:00 8.7 2 15.3 4.2 8.6 2.1 15.3 3.8 7.2 2.2 14.9 1.5 19 13 21 255 0 0 0 0 8.8 0 9 8.8 04/22/2005 18:40:00 9.1 2.5 14.9 2.6 9 2.5 14.5 2.6 7.4 2.6 13 1.5 17 17 26 255 0 0 0 0 8.7 0 8.8 8.8 04/22/2005 18:50:00 8.5 2.3 17.2 4.2 8.4 2.3 17.2 4.2 7 2.3 14.5 2.6 16 14 27 255 0 0 0 0 8.7 0 8.8 8.5 04/22/2005 19:00:00 8.6 1.9 13.7 3.8 8.6 1.9 13.7 4.2 7.2 2 14.1 2.6 20 13 20 255 0 0 0 0 8.7 0 8.8 8.5 04/22/2005 19:10:00 8.7 1.9 13 2.3 8.7 1.9 13 2.3 7.6 2 13 2.3 26 13 39 255 0 0 0 0 8.7 0 8.8 8.8 04/22/2005 19:20:00 9.4 1.7 14.1 5.3 9.4 1.7 14.1 5.7 8.1 1.7 13 4.6 20 11 29 255 0 0 0 0 8.6 0 8.8 8.5 04/22/2005 19:30:00 8.7 1.7 13.7 4.2 8.6 1.7 14.1 4.2 7.4 1.8 14.1 3.4 22 12 21 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 19:40:00 8.4 1.5 12.6 4.2 8.4 1.5 13 3.4 6.9 1.7 12.2 3.4 21 12 12 255 0 0 0 0 8.5 0 8.5 8.5 04/22/2005 19:50:00 8.2 1.7 12.6 4.6 8.1 1.7 12.6 4.6 6.9 1.9 13 3 26 12 22 255 0 0 0 0 8.4 0 8.5 8.5 04/22/2005 20:00:00 8 2 12.6 3.4 8 2.1 12.6 3 6.7 2.1 11.8 1.9 25 15 16 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 20:10:00 8.6 1.8 12.6 4.2 8.6 1.8 13 4.6 7.3 1.8 12.2 3.4 29 15 33 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 20:20:00 8.2 1.7 12.6 4.6 8.2 1.7 12.2 4.2 6.9 1.7 11.8 3 25 14 12 255 0 0 0 0 8.4 0 8.5 8.5 04/22/2005 20:30:00 8.9 1.7 13.3 5.3 8.9 1.8 13 4.9 7.7 1.8 12.2 3 29 12 44 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 20:40:00 9.2 1.8 14.1 4.9 9.2 1.8 14.1 5.3 8 1.8 13 4.2 30 12 39 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 20:50:00 8.1 2.2 13 3 8 2.2 13.3 3.4 6.9 2.1 13 2.6 38 13 44 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 21:00:00 6.8 2 12.6 2.6 6.8 2.1 13 2.6 6.1 2.1 13 2.3 30 15 42 255 0 0 0 0 8.5 0 8.8 8.5 04/22/2005 21:10:00 6.6 1.4 10.3 3 6.6 1.5 11.1 2.6 5.7 1.5 9.9 1.9 39 15 23 255 0 0 0 0 8.4 0 8.5 8.3 04/22/2005 21:20:00 6.4 1.5 10.3 3 6.4 1.5 10.3 3.4 5.4 1.5 9.5 2.3 24 16 32 255 0 0 0 0 8.2 0 8.5 8.3 04/22/2005 21:30:00 6.6 1.3 9.5 3.8 6.7 1.3 9.5 3.4 5.7 1.5 9.9 2.6 25 15 16 255 0 0 0 0 8.2 0 8.3 8.3 04/22/2005 21:40:00 5.9 1.6 10.3 3 5.8 1.6 10.7 2.6 5.1 1.6 10.3 1.9 62 23 29 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 21:50:00 5.2 1 8.4 2.6 5.2 1.1 8.8 2.6 4.4 1 7.2 1.9 68 17 76 255 0 0 0 0 8 0 8.3 8 04/22/2005 22:00:00 4.9 1 7.2 2.6 4.9 1.1 7.6 2.6 4.3 1.1 7.2 1.9 59 15 43 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 22:10:00 4.6 1 7.2 1.5 4.6 1 7.2 1.5 4 1.1 6.5 1.1 74 18 81 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 22:20:00 3.5 1 6.1 0.7 3.4 1.1 6.1 0.7 2.9 1.2 5.7 0.4 85 14 77 255 0 0 0 0 8.2 0 8.5 8 04/22/2005 22:30:00 3 1 4.9 0.4 3 1 5.3 0.7 2.2 0.9 4.9 0.4 74 18 71 255 0 0 0 0 8.1 0 8.3 8 04/22/2005 22:40:00 3.6 0.9 5.7 1.5 3.5 0.9 5.7 1.1 2.9 0.8 5.3 1.1 82 15 91 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 22:50:00 4.5 1 8 2.3 4.5 0.9 8 2.3 3.6 1 7.2 1.1 92 15 106 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 23:00:00 3.1 1.3 5.7 0.4 3 1.3 6.1 0.4 2.4 1.2 5.7 0.4 74 23 67 255 0 0 0 0 8.3 0 8.5 8.3 04/22/2005 23:10:00 4.2 1.1 6.8 1.1 4.3 1.2 7.2 0.4 3.5 1 6.1 1.1 72 21 69 255 0 0 0 0 8.5 0 8.8 8.3 04/22/2005 23:20:00 4.5 1.3 8.8 1.9 4.5 1.3 8.4 1.5 3.9 1.3 8 1.5 80 17 61 255 0 0 0 0 8.7 0 9 8.5 04/22/2005 23:30:00 5.3 1.1 9.5 2.3 5.2 1.1 9.5 2.3 4.4 1.1 7.2 1.5 89 13 100 255 0 0 0 0 8.8 0 9 8.8 04/22/2005 23:40:00 5.8 1.7 13 3 5.7 1.7 13.3 2.6 4.8 1.5 11.5 1.5 78 20 84 255 0 0 0 0 8.9 0 9 8.8 04/22/2005 23:50:00 6.1 1.6 10.7 2.6 6.1 1.6 10.3 3 5.3 1.5 9.1 1.9 91 17 94 255 0 0 0 0 9 0 9 9 04/23/2005 00:00:00 6.1 1.2 9.1 3 6.1 1.3 9.1 2.6 5.3 1.3 8.8 1.9 87 21 103 255 0 0 0 0 9 0 9 9 04/23/2005 00:10:00 5 1.6 8.4 1.5 5 1.6 8.4 1.1 4.4 1.5 9.9 1.9 93 24 102 255 0 0 0 0 8.8 0 9 8.8 04/23/2005 00:20:00 4.7 1.2 8 1.9 4.7 1.2 7.6 2.3 3.9 1.1 6.8 1.1 77 26 17 255 0 0 0 0 8.9 0 9 8.8 04/23/2005 00:30:00 3.1 1.3 6.8 0.4 3 1.3 6.5 0.4 2.5 1.3 6.1 0.4 75 21 86 255 0 0 0 0 8.8 0 9 8.8 04/23/2005 00:40:00 4.4 1 6.8 0.7 4.4 1 6.8 1.1 3.6 1 6.1 0.7 88 18 85 255 0 0 0 0 8.5 0.1 8.8 8.5 04/23/2005 00:50:00 3.3 0.9 6.8 0.7 3.4 0.9 6.5 1.5 2.8 1 4.6 0.4 82 22 62 255 0 0 0 0 8.5 0 8.8 8.5 04/23/2005 01:00:00 3.9 1.1 6.8 0.7 3.8 1.1 6.8 1.1 3.1 1.2 6.5 0.4 75 22 77 255 0 0 0 0 8.6 0 8.8 8.5 04/23/2005 01:10:00 4.3 0.9 7.2 2.6 4.2 0.9 6.8 2.3 3.5 1 6.8 1.9 73 15 66 255 0 0 0 0 8.7 0 8.8 8.5 04/23/2005 01:20:00 4.4 1.2 8.8 1.9 4.3 1.3 8.4 1.9 3.5 1.2 6.8 0.7 71 17 69 255 0 0 0 0 8.7 0 8.8 8.8 04/23/2005 01:30:00 4.6 1 7.2 1.9 4.5 1 8 2.3 3.9 1 6.5 1.1 81 16 73 255 0 0 0 0 8.8 0 9 8.5 04/23/2005 01:40:00 4.6 0.9 7.6 2.6 4.6 0.9 7.2 2.6 3.9 0.8 6.1 2.3 91 16 70 255 0 0 0 0 8.5 0 8.8 8.3 04/23/2005 01:50:00 3.6 0.7 6.1 1.9 3.5 0.8 5.3 1.9 2.8 0.8 4.9 1.1 91 13 76 255 0 0 0 0 8.1 0.1 8.5 8 04/23/2005 02:00:00 2.9 0.7 4.9 1.1 2.8 0.8 4.9 0.7 2.2 0.7 4.2 0.7 83 16 112 255 0 0 0 0 8 0 8.3 8 04/23/2005 02:10:00 4.1 1 6.8 1.9 4.1 1 6.5 1.5 3.3 1 5.7 1.5 77 15 79 255 0 0 0 0 8 0 8.3 7.8 04/23/2005 02:20:00 4.7 1.1 7.2 1.5 4.6 1.1 7.2 1.9 3.7 1 6.1 1.1 79 12 85 255 0 0 0 0 8.3 0 8.5 8 04/23/2005 02:30:00 4.3 1 6.8 1.5 4.2 1.1 6.5 1.9 3.7 1.1 6.1 1.5 65 17 68 255 0 0 0 0 8.7 0 9 8.5 04/23/2005 02:40:00 5.3 1.2 8.4 2.3 5.3 1.2 8 2.6 4.5 1.1 7.6 1.9 68 17 44 255 0 0 0 0 9 0.1 9.3 8.8 04/23/2005 02:50:00 5.3 1.5 8.8 2.6 5.2 1.6 8.8 2.3 4.5 1.5 8 1.5 74 15 63 255 0 0 0 0 9.2 0 9.3 9 04/23/2005 03:00:00 4.7 0.8 7.2 2.6 4.6 0.8 6.8 2.6 3.9 1 6.5 1.5 85 15 95 255 0 0 0 0 9 0 9.3 9 04/23/2005 03:10:00 5.3 1.1 8.4 2.3 5.3 1.1 8.4 3 4.3 1.2 8 1.5 86 15 71 255 0 0 0 0 9 0 9 9 04/23/2005 03:20:00 5 1.1 8 2.3 5 1.2 8 1.5 4.1 1.2 7.2 0.7 80 17 69 255 0 0 0 0 9 0 9 9 04/23/2005 03:30:00 5.3 1.2 8.8 2.6 5.3 1.2 8.8 2.6 4.6 1.2 8 1.9 67 22 57 255 0 0 0 0 9 0 9.3 9 04/23/2005 03:40:00 5.1 1.2 8.4 2.6 5.1 1.2 8.4 2.6 4.3 1.2 8 1.5 72 22 45 255 0 0 0 0 9.2 0.1 9.6 8.8 04/23/2005 03:50:00 4.5 1 8 2.3 4.4 1 8 2.3 3.7 1 6.8 1.9 80 14 64 255 0 0 0 0 8.8 0 9 8.8 04/23/2005 04:00:00 5.3 1 7.6 2.6 5.2 0.9 7.6 2.6 4.3 1 7.2 1.5 77 17 93 255 0 0 0 0 8.8 0 9 8.5 04/23/2005 04:10:00 4.3 0.8 6.5 2.6 4.2 0.8 6.5 2.3 3.4 0.8 6.1 1.9 88 11 96 255 0 0 0 0 8.4 0 8.8 8.5 04/23/2005 04:20:00 4.4 1.1 6.8 1.9 4.4 1.1 7.2 1.5 3.7 1.1 6.1 1.1 83 15 90 255 0 0 0 0 8.5 0 8.5 8.5 04/23/2005 04:30:00 5.1 0.8 6.8 3 5.1 0.8 6.8 2.6 4.2 1 6.5 1.9 93 11 89 255 0 0 0 0 8.4 0 8.5 8.3 04/23/2005 04:40:00 5.2 0.8 7.2 3 5.1 0.9 7.2 3 4.2 1 6.5 1.1 88 10 86 255 0 0 0 0 8.3 0 8.5 8.3 04/23/2005 04:50:00 5.4 1.1 9.1 2.6 5.3 1.1 9.5 3 4.5 1 9.1 1.9 83 13 63 255 0 0 0 0 8.2 0 8.5 8 04/23/2005 05:00:00 4.6 1.2 8 1.9 4.5 1.3 7.6 1.9 3.9 1.1 6.5 1.5 63 16 86 255 0 0 0 0 8.7 0 9 8.5 04/23/2005 05:10:00 4.6 1.3 9.5 1.9 4.5 1.3 9.9 1.9 3.8 1.1 6.8 1.5 65 17 73 255 0 0 0 0 8.9 0 9 8.8 04/23/2005 05:20:00 4.7 0.9 7.2 2.6 4.6 0.9 7.2 2.6 3.9 1 6.5 1.5 73 18 48 255 0 0 0 0 8.9 0 9 8.8 04/23/2005 05:30:00 4.3 0.7 6.5 2.6 4.2 0.7 6.1 2.3 3.3 0.7 6.1 1.9 80 12 84 255 0 0 0 0 8.5 0 8.8 8.3 04/23/2005 05:40:00 4.3 0.8 6.1 1.9 4.2 0.8 6.1 1.9 3.5 0.8 5.7 1.5 83 12 91 255 0 0 0 0 8.4 0 8.5 8.3 04/23/2005 05:50:00 4.6 0.9 6.8 2.3 4.5 1 6.5 1.9 3.8 1 6.5 1.5 98 12 87 255 0 0 0 0 8.3 0 8.5 8.3 04/23/2005 06:00:00 4.8 0.8 7.2 1.9 4.7 0.9 6.8 1.9 3.6 1 6.5 0.4 106 13 124 255 0 0 0 0 8 0 8.3 7.8 04/23/2005 06:10:00 4.8 1 7.2 2.6 4.7 1 6.8 2.3 3.8 1 6.1 1.5 110 14 127 255 0 0 0 0 7.8 0 8 7.5 04/23/2005 06:20:00 4.9 1 8 2.3 4.8 1.1 7.2 2.3 3.8 1 6.5 1.9 108 15 106 255 0 0 0 0 7.8 0 7.8 7.5 04/23/2005 06:30:00 4.8 0.8 7.2 2.6 4.7 0.8 7.2 2.6 3.8 0.9 6.1 1.5 104 12 127 255 0 0 0 0 8 0 8.3 7.8 04/23/2005 06:40:00 5 0.8 7.2 3 4.9 0.8 6.8 2.6 4.2 0.9 6.5 1.1 104 12 100 255 0 0 0 0 8.1 0 8.3 8 04/23/2005 06:50:00 5 0.9 8 2.6 4.9 0.9 7.6 2.6 4.1 1.1 6.5 1.9 102 13 99 255 0 0 0 0 8.3 0 8.5 8.3 04/23/2005 07:00:00 4.6 0.9 6.8 1.9 4.5 1 6.8 1.9 3.6 0.9 6.5 0.7 102 11 90 255 0 0 0 0 8.1 0.1 8.3 8 04/23/2005 07:10:00 4.3 0.7 6.1 2.6 4.1 0.8 6.1 2.3 3.5 0.7 5.3 1.9 102 9 102 255 0 0 0 0 8 0 8 7.8 04/23/2005 07:20:00 4.1 0.7 6.1 2.3 3.9 0.7 5.7 1.5 3.1 0.8 4.9 0.7 109 12 116 255 0 0 0 0 7.8 0 8 7.8 04/23/2005 07:30:00 3.9 0.8 6.1 1.9 3.8 0.8 6.5 1.5 3 0.7 4.9 1.1 110 15 99 255 0 0 0 0 8 0 8 7.8 04/23/2005 07:40:00 4.3 0.8 6.5 1.9 4.1 0.8 6.1 1.9 3.4 0.9 5.7 1.1 102 12 108 255 0 0 0 0 8 0 8.3 7.8 04/23/2005 07:50:00 3.5 0.7 4.9 1.9 3.3 0.7 4.9 1.5 2.7 0.8 4.6 1.1 96 12 108 255 0 0 0 0 8.1 0 8.3 8.3 04/23/2005 08:00:00 3.8 0.6 4.9 2.3 3.6 0.6 5.3 2.3 3 0.7 4.6 1.1 101 11 106 255 0 0 0 0 8.3 0 8.5 8.3 04/23/2005 08:10:00 3.3 0.7 5.3 1.5 3.1 0.7 5.3 1.5 2.6 0.7 4.6 0.7 99 12 112 255 0 0 0 0 8.4 0 8.5 8.5 04/23/2005 08:20:00 3.2 0.6 4.9 1.5 3 0.6 4.6 1.5 2.4 0.6 3.8 1.1 105 12 110 255 0 0 0 0 8.6 0 8.8 8.5 04/23/2005 08:30:00 3 0.5 4.2 1.9 2.8 0.6 4.2 1.5 2.5 0.6 3.8 0.7 102 10 74 255 0 0 0 0 8.8 0 9 8.8 04/23/2005 08:40:00 3.2 0.5 4.6 1.9 3 0.6 4.6 1.5 2.6 0.6 4.2 0.4 103 10 91 255 0 0 0 0 8.8 0 8.8 8.8 04/23/2005 08:50:00 2.5 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.9 0.6 3.4 0.4 100 13 93 255 0 0 0 0 8.9 0 9 8.8 04/23/2005 09:00:00 2.4 0.5 3.8 1.1 2.1 0.6 3.8 0.7 1.8 0.5 3.4 0.4 104 13 92 255 0 0 0 0 9.2 0 9.3 9 04/23/2005 09:10:00 2.4 0.5 3.8 1.1 2 0.5 3.8 0.7 1.8 0.6 3.8 0.4 108 13 110 255 0 0 0 0 9.4 0 9.6 9.3 04/23/2005 09:20:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.7 0.6 3 0.4 100 14 100 255 0 0 0 0 9.5 0 9.6 9.6 04/23/2005 09:30:00 3.2 1.1 6.1 0.7 3 1.2 6.5 0.4 2.5 1.2 5.7 0.4 73 19 55 255 0 0 0 0 9.6 0 9.8 9.6 04/23/2005 09:40:00 3.9 1 6.5 1.5 3.8 1 6.1 1.5 3.3 0.9 5.7 1.1 70 20 78 255 0 0 0 0 9.9 0 10.1 9.8 04/23/2005 09:50:00 4.3 1.1 7.2 2.3 4.2 1.1 7.2 1.9 3.7 1 6.8 1.5 68 16 69 255 0 0 0 0 10 0 10.1 9.8 04/23/2005 10:00:00 5.2 1 8 3 5.2 1 8 3 4.4 1.2 7.2 1.5 57 19 29 255 0 0 0 0 10.2 0 10.3 10.1 04/23/2005 10:10:00 4 1 7.2 1.9 3.9 0.9 7.2 1.9 3.3 1 6.5 0.4 49 17 44 255 0 0 0 0 10.4 0 10.6 10.3 04/23/2005 10:20:00 6.2 1.5 9.9 3 6.1 1.6 9.9 2.6 5.3 1.7 9.5 2.3 47 13 47 255 0 0 0 0 10.5 0 10.6 10.3 04/23/2005 10:30:00 6.4 1.1 9.1 3.4 6.3 1.2 9.1 3 5.5 1.2 8.8 2.6 50 10 51 255 0 0 0 0 10.6 0 10.6 10.6 04/23/2005 10:40:00 5.2 1.2 9.5 2.6 5.1 1.3 9.1 1.9 4.4 1.3 6.8 1.1 50 13 30 255 0 0 0 0 10.6 0 10.6 10.6 04/23/2005 10:50:00 5.6 1.3 8.8 2.6 5.4 1.3 8.8 2.6 4.8 1.2 8.4 2.3 43 15 35 255 0 0 0 0 10.3 0.1 10.6 10.3 04/23/2005 11:00:00 5.7 1.3 9.1 3 5.7 1.5 9.1 2.6 5.1 1.3 8.8 2.6 50 14 43 255 0 0 0 0 10.3 0 10.6 10.3 04/23/2005 11:10:00 5.2 0.9 7.6 3 5 1 8.4 2.6 4.3 1 7.2 2.3 44 15 48 255 0 0 0 0 10.5 0 10.6 10.6 04/23/2005 11:20:00 5.1 0.8 7.6 3 5.1 0.9 7.2 2.6 4.5 1 6.8 2.3 44 11 37 255 0 0 0 0 10.6 0 10.6 10.6 04/23/2005 11:30:00 4.8 0.9 6.8 2.6 4.6 0.9 6.8 2.3 4 1 6.5 1.5 44 12 69 255 0 0 0 0 10.6 0 10.6 10.6 04/23/2005 11:40:00 4.2 0.7 5.7 1.9 4 0.8 6.1 1.1 3.5 1 5.7 0.4 50 11 66 255 0 0 0 0 10.5 0 10.6 10.6 04/23/2005 11:50:00 3.7 0.7 5.3 1.9 3.5 0.8 5.7 1.1 3.1 0.8 4.9 1.1 51 11 43 255 0 0 0 0 10.7 0.1 11.1 10.6 04/23/2005 12:00:00 3.5 0.7 4.9 1.9 3.3 0.7 5.3 1.1 2.9 0.9 5.3 1.1 45 13 42 255 0 0 0 0 11.2 0 11.4 11.1 04/23/2005 12:10:00 3 1.1 6.1 0.7 2.8 1.2 6.1 0.4 2.6 1.2 6.1 0.4 54 15 55 255 0 0 0 0 11.4 0 11.7 11.4 04/23/2005 12:20:00 2.4 0.6 4.2 1.1 2.1 0.7 3.8 0.4 1.9 0.6 3.8 0.7 84 17 28 255 0 0 0 0 11.7 0 11.7 11.7 04/23/2005 12:30:00 1.9 0.8 4.2 0.4 1.3 0.8 4.2 0.4 1.5 0.9 4.6 0.4 347 16 46 255 0 0 0 0 12.1 0.2 12.5 11.7 04/23/2005 12:40:00 2.6 0.4 3.4 1.5 2.1 0.5 3 0.7 2.4 0.5 3.4 1.1 345 15 351 255 0 0 0 0 12.1 0 12.5 11.9 04/23/2005 12:50:00 2.7 0.5 3.8 1.5 2.2 0.6 3.8 0.7 1.9 0.9 3.4 0.4 346 13 350 255 0 0 0 0 12.3 0.1 12.7 11.9 04/23/2005 13:00:00 2.1 0.5 3.4 0.7 1.6 0.6 3.4 0.4 1.5 0.7 3 0.4 343 15 349 255 0 0 0 0 12.2 0 12.5 11.9 04/23/2005 13:10:00 1.6 0.6 3 0.4 1 0.6 3 0.4 1.1 0.7 2.6 0.4 321 26 296 255 0 0 0 0 12.2 0 12.5 11.9 04/23/2005 13:20:00 1.9 0.7 3 0.4 1.5 0.8 3 0.4 1.5 0.8 3.4 0.4 295 15 279 255 0 0 0 0 11.9 0.1 12.5 11.7 04/23/2005 13:30:00 1.4 0.5 3.4 0.4 0.9 0.5 2.6 0.4 1.1 0.6 2.6 0.4 312 23 326 255 0 0 0 0 12.4 0.3 13.3 11.9 04/23/2005 13:40:00 1 0.5 2.6 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.6 0.4 316 32 311 255 0 0 0 0 12.9 0 13.3 12.7 04/23/2005 13:50:00 2.1 0.4 3.4 1.1 1.7 0.5 3 0.7 1.8 0.5 3 0.4 301 12 308 255 0 0 0 0 12.3 0.2 13 11.9 04/23/2005 14:00:00 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 1.5 0.7 3.4 0.4 280 20 263 255 0 0 0 0 12.3 0.2 12.7 11.9 04/23/2005 14:10:00 2.5 0.6 3.8 0.7 2.2 0.7 3.8 0.4 2.3 0.7 3.8 0.4 284 17 279 255 0 0 0 0 12.4 0 12.7 12.2 04/23/2005 14:20:00 2.3 0.9 4.2 0.4 2 0.9 4.2 0.4 1.9 0.9 3.8 0.4 280 24 271 255 0 0 0 0 12.5 0.2 12.7 12.2 04/23/2005 14:30:00 1.8 0.6 3 0.4 1.4 0.7 3 0.4 1.3 0.6 2.6 0.4 288 22 261 255 0 0 0 0 12.8 0 13.3 12.7 04/23/2005 14:40:00 2.7 0.6 4.6 0.7 2.4 0.7 4.2 0.4 2.3 0.8 3.8 0.4 277 17 298 255 0 0 0 0 12.9 0.1 13.5 12.7 04/23/2005 14:50:00 2.4 0.6 3.8 0.4 2.2 0.6 3.8 0.4 2.2 0.6 3.8 0.4 288 22 265 255 0 0 0 0 13 0.2 13.8 12.7 04/23/2005 15:00:00 2.7 0.6 4.2 0.7 2.4 0.7 3.8 0.4 2.2 0.7 3.8 0.4 298 17 322 255 0 0 0 0 13 0.2 13.5 12.7 04/23/2005 15:10:00 3 0.9 4.6 0.4 2.8 1 4.2 0.4 2.5 1.2 4.6 0.4 300 21 302 255 0 0 0 0 12.7 0 13.3 12.5 04/23/2005 15:20:00 3.7 0.8 5.3 1.1 3.6 0.8 4.9 0.4 3.4 0.8 5.3 1.1 292 12 290 255 0 0 0 0 12.7 0.2 13.3 12.2 04/23/2005 15:30:00 3 1.1 5.3 0.7 2.8 1.2 4.9 0.7 2.4 1.2 4.6 0.4 291 24 302 255 0 0 0 0 12.4 0.1 13 12.2 04/23/2005 15:40:00 3.9 0.6 5.3 1.9 3.8 0.7 5.3 1.9 3.4 0.8 4.9 0.4 290 11 257 255 0 0 0 0 12.4 0.1 12.7 12.2 04/23/2005 15:50:00 4.1 0.7 6.1 1.9 4 0.7 5.7 1.9 3.6 0.8 5.7 1.1 291 14 291 255 0 0 0 0 12.5 0.1 12.7 12.2 04/23/2005 16:00:00 3.9 0.8 6.8 1.9 3.7 0.8 6.5 1.9 3.2 0.9 5.7 1.1 295 17 312 255 0 0 0 0 12.4 0.1 13 12.2 04/23/2005 16:10:00 4.2 1.1 6.5 1.1 4 1.1 6.5 0.7 3.5 1.1 6.1 0.7 303 15 296 255 0 0 0 0 12.7 0 13 12.5 04/23/2005 16:20:00 3.8 0.9 5.7 1.5 3.6 0.9 5.3 0.7 3.3 1.1 6.5 0.4 303 16 287 255 0 0 0 0 12.5 0.1 13 12.5 04/23/2005 16:30:00 3.7 1 5.7 1.1 3.5 1 5.3 0.4 3 1.1 5.3 0.4 303 16 294 255 0 0 0 0 12.6 0 13 12.5 04/23/2005 16:40:00 3.5 1 6.1 0.4 3.3 1.2 5.7 0.4 3 1.2 5.7 0.4 293 17 300 255 0 0 0 0 12.7 0 13 12.5 04/23/2005 16:50:00 3.7 1.1 6.1 0.7 3.5 1.1 6.1 0.4 2.9 1.1 5.3 0.4 302 14 305 255 0 0 0 0 12.6 0 13.3 12.5 04/23/2005 17:00:00 3.8 0.9 6.5 1.5 3.7 0.9 6.5 1.5 3.2 1 5.3 0.4 293 15 266 255 0 0 0 0 12.5 0.2 13.3 12.2 04/23/2005 17:10:00 2.9 1.1 5.7 0.4 2.7 1.1 5.7 0.4 2.2 1.1 5.3 0.4 281 19 273 255 0 0 0 0 12.5 0 12.7 12.2 04/23/2005 17:20:00 2.7 1.1 5.7 0.4 2.4 1.2 5.3 0.4 2.3 1.2 4.9 0.4 289 17 275 255 0 0 0 0 12.3 0 12.7 11.9 04/23/2005 17:30:00 3.6 1 5.7 0.4 3.4 1.1 5.7 0.4 3.1 1.2 5.7 0.4 287 15 265 255 0 0 0 0 11.9 0 12.2 11.9 04/23/2005 17:40:00 3.4 0.8 5.3 1.5 3.2 0.8 4.9 0.7 2.9 0.8 4.9 1.1 292 17 284 255 0 0 0 0 11.7 0 12.2 11.7 04/23/2005 17:50:00 4.4 1 7.2 1.5 4.3 1.1 6.5 1.1 3.8 1.1 6.5 0.4 298 14 297 255 0 0 0 0 11.7 0 11.9 11.4 04/23/2005 18:00:00 2.9 1 6.1 0.7 2.7 1.1 6.1 0.4 2.3 0.9 4.9 0.4 292 21 286 255 0 0 0 0 11.3 0 11.4 11.4 04/23/2005 18:10:00 3.2 0.8 4.9 1.1 2.9 0.9 4.9 0.4 2.6 0.9 4.9 0.4 291 18 302 255 0 0 0 0 11.3 0 11.4 11.1 04/23/2005 18:20:00 4.4 1.2 7.2 1.5 4.3 1.3 7.2 0.7 3.7 1.4 7.2 0.4 287 15 291 255 0 0 0 0 10.9 0.2 11.1 10.6 04/23/2005 18:30:00 3.9 0.8 6.1 1.9 3.7 1 6.1 1.1 3.2 0.8 5.7 0.7 287 16 288 255 0 0 0 0 10.3 0 10.6 10.1 04/23/2005 18:40:00 3.1 1.1 5.7 0.4 2.9 1.2 5.3 0.4 2.6 1.1 5.7 0.4 284 19 280 255 0 0 0 0 9.8 0 10.1 9.6 04/23/2005 18:50:00 3.4 0.9 5.7 1.5 3.2 1 5.7 0.7 2.7 1 5.3 0.4 287 16 298 255 0 0 0 0 9.5 0 9.6 9.3 04/23/2005 19:00:00 3.4 1 6.1 1.5 3.2 1.1 5.7 0.7 2.8 0.9 5.3 0.7 283 17 297 255 0 0 0 0 9.2 0 9.3 9 04/23/2005 19:10:00 4.2 1.1 6.8 0.7 4 1.1 6.5 0.4 3.2 1 5.7 0.4 281 15 282 255 0 0 0 0 9 0 9 8.8 04/23/2005 19:20:00 3.6 1.2 7.6 0.7 3.5 1.2 7.2 0.4 2.8 1.2 6.5 0.4 271 20 262 255 0 0 0 0 8.7 0 9 8.8 04/23/2005 19:30:00 3.4 1.2 6.8 0.7 3.3 1.2 7.2 0.7 2.5 1.2 5.7 0.4 276 23 284 255 0 0 0 0 8.6 0 8.8 8.5 04/23/2005 19:40:00 3.8 1.3 7.2 1.9 3.7 1.3 7.2 1.5 3 1.3 7.2 0.4 275 21 275 255 0 0 0 0 8.4 0 8.5 8.5 04/23/2005 19:50:00 3.2 1.1 6.1 0.7 3.1 1.1 5.7 0.4 2.3 1.2 5.3 0.4 278 18 289 255 0 0 0 0 8.3 0 8.5 8.3 04/23/2005 20:00:00 3.7 1.1 6.5 1.5 3.5 1.1 6.5 0.4 2.7 1.2 6.5 0.4 272 18 259 255 0 0 0 0 8.1 0 8.3 8 04/23/2005 20:10:00 3.6 1.3 6.8 1.1 3.6 1.4 6.8 0.4 2.5 1.4 5.7 0.4 271 20 276 255 0 0 0 0 8 0 8.3 7.8 04/23/2005 20:20:00 4 1.1 6.8 1.1 3.9 1.2 7.2 0.7 2.9 1.1 5.7 0.4 276 21 267 255 0 0 0 0 7.8 0 7.8 7.5 04/23/2005 20:30:00 3.6 1 6.8 1.1 3.5 1 6.8 0.7 2.6 1.2 5.7 0.4 275 22 229 255 0 0 0 0 7.6 0 7.8 7.5 04/23/2005 20:40:00 3.2 1.1 5.7 0.7 3 1.2 5.7 0.4 2.2 1.1 5.7 0.4 268 22 255 255 0 0 0 0 7.4 0 7.5 7.3 04/23/2005 20:50:00 3.3 1 6.1 0.7 3.2 1.1 6.1 0.4 2.4 1.2 5.7 0.4 267 21 261 255 0 0 0 0 7.3 0 7.3 7.3 04/23/2005 21:00:00 3.6 1.1 6.8 1.5 3.5 1.1 6.8 1.1 2.6 1.2 6.5 0.4 268 15 277 255 0 0 0 0 7.3 0 7.3 7.3 04/23/2005 21:10:00 3.1 0.9 4.9 0.7 2.8 1 5.3 0.4 2.2 1 4.6 0.4 266 18 261 255 0 0 0 0 7.1 0 7.3 7 04/23/2005 21:20:00 3 1.1 5.7 0.4 2.7 1.2 6.1 0.4 1.8 1.2 5.3 0.4 259 24 255 255 0 0 0 0 7.1 0 7.3 7 04/23/2005 21:30:00 2.9 1 4.9 0.4 2.7 1.1 4.9 0.4 1.9 1.1 4.2 0.4 257 18 255 255 0 0 0 0 7 0 7.3 7 04/23/2005 21:40:00 2.5 0.9 4.9 0.4 2.2 1 5.3 0.4 1.7 0.9 3.8 0.4 256 21 253 255 0 0 0 0 6.9 0 7 7 04/23/2005 21:50:00 1.9 0.7 3.8 0.4 1.6 0.9 3.8 0.4 1.2 0.8 3 0.4 258 17 261 255 0 0 0 0 6.9 0 7 6.7 04/23/2005 22:00:00 1.2 0.7 3.4 0.4 0.9 0.7 3.4 0.4 0.7 0.5 2.3 0.4 258 19 243 255 0 0 0 0 6.7 0 7 6.7 04/23/2005 22:10:00 0.8 0.6 2.6 0.4 0.6 0.4 2.6 0.4 0.5 0.3 1.9 0.4 280 23 255 255 0 0 0 0 6.7 0 7 6.7 04/23/2005 22:20:00 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.4 2.3 0.4 251 9 257 255 0 0 0 0 6.7 0 6.7 6.7 04/23/2005 22:30:00 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 250 9 249 255 0 0 0 0 6.7 0 6.7 6.7 04/23/2005 22:40:00 1.2 0.7 3 0.4 0.9 0.6 2.6 0.4 0.6 0.5 2.6 0.4 253 20 273 255 0 0 0 0 6.6 0 6.7 6.7 04/23/2005 22:50:00 1 0.5 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0.3 1.9 0.4 250 21 255 255 0 0 0 0 6.6 0 6.7 6.5 04/23/2005 23:00:00 0.5 0.4 2.3 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 274 11 253 255 0 0 0 0 6.5 0 6.7 6.5 04/23/2005 23:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 15 310 255 0 0 0 0 6.4 0 6.7 6.2 04/23/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 255 255 0 0 0 0 6.2 0 6.5 6 04/23/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 255 255 0 0 0 0 6.1 0 6.2 6 04/23/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 255 255 0 0 0 0 6.1 0 6.2 6 04/23/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 255 255 0 0 0 0 5.9 0 6 5.7 04/24/2005 00:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 310 255 0 0 0 0 5.9 0 6 5.7 04/24/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 255 255 0 0 0 0 5.9 0 6 5.7 04/24/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 255 255 0 0 0 0 5.8 0 6 5.7 04/24/2005 00:30:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 238 45 216 255 0 0 0 0 5.8 0 6 5.7 04/24/2005 00:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 203 255 0 0 0 0 5.8 0 6 5.7 04/24/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 255 255 0 0 0 0 5.7 0 6 5.7 04/24/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 255 255 0 0 0 0 5.7 0 5.7 5.7 04/24/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 255 255 0 0 0 0 5.7 0 5.7 5.7 04/24/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 255 255 0 0 0 0 5.7 0 6 5.7 04/24/2005 01:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 0 203 255 0 0 0 0 5.7 0 5.7 5.7 04/24/2005 01:40:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 205 3 210 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 01:50:00 1.3 0.3 1.9 0.7 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 234 8 229 255 0 0 0 0 5.6 0 5.7 5.7 04/24/2005 02:00:00 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 234 2 240 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 02:10:00 1.3 0.3 1.9 0.7 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 245 4 250 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 02:20:00 1 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 251 2 253 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 02:30:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 253 1 255 255 0 0 0 0 5.6 0 5.7 5.7 04/24/2005 02:40:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 255 4 252 255 0 0 0 0 5.6 0 5.7 5.7 04/24/2005 02:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 263 255 0 0 0 0 5.6 0 5.7 5.7 04/24/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 255 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 03:10:00 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 286 24 289 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 03:20:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 320 1 320 255 0 0 0 0 5.5 0 5.7 5.5 04/24/2005 03:30:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 318 0 318 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 03:40:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 312 5 305 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 03:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 301 0 303 255 0 0 0 0 5.5 0 5.7 5.5 04/24/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 0 0 0 0 5.5 0 5.7 5.5 04/24/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 0 0 0 0 5.4 0 5.5 5.5 04/24/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 0 0 0 0 5.4 0 5.5 5.2 04/24/2005 04:40:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 271 45 203 255 0 0 0 0 5.4 0 5.5 5.2 04/24/2005 04:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 194 255 0 0 0 0 5.4 0 5.5 5.5 04/24/2005 05:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 0 194 255 0 0 0 0 5.4 0 5.5 5.5 04/24/2005 05:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 22 194 255 0 0 0 0 5.4 0 5.7 5.5 04/24/2005 05:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 157 29 216 255 0 0 0 0 5.4 0 5.5 5.5 04/24/2005 05:30:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 229 7 222 255 0 0 0 0 5.4 0 5.7 5.2 04/24/2005 05:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 202 17 192 255 0 0 0 0 5.4 0 5.7 5.5 04/24/2005 05:50:00 1.4 0.6 2.6 0.4 1.2 0.6 2.3 0.4 0.7 0.5 1.9 0.4 190 5 192 255 0 0 0 0 5.5 0 5.7 5.5 04/24/2005 06:00:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 185 17 194 255 0 0 0 0 5.5 0 5.7 5.5 04/24/2005 06:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 179 2 181 255 0 0 0 0 5.4 0 5.5 5.5 04/24/2005 06:20:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 163 22 127 255 0 0 0 0 5.5 0 5.7 5.5 04/24/2005 06:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 191 12 206 255 0 0 0 0 5.4 0 5.5 5.2 04/24/2005 06:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 0 192 255 0 0 0 0 5.6 0 5.7 5.5 04/24/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 192 0 255 255 0 0 0 0 5.7 0 6 5.7 04/24/2005 07:00:00 1.1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 273 17 262 255 0 0 0 0 6.1 0 6.2 5.7 04/24/2005 07:10:00 1.4 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.6 0.4 2.6 0.4 260 13 270 255 0 0 0 0 6.2 0 6.2 6 04/24/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 216 255 0 0 0 0 6.4 0.2 7 6.2 04/24/2005 07:30:00 1.3 0.7 2.6 0.4 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 264 24 232 255 0 0 0 0 7.1 0 7.3 7 04/24/2005 07:40:00 1 0.7 2.6 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 247 47 199 255 0 0 0 0 6.9 0 7.3 6.7 04/24/2005 07:50:00 1.3 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 195 22 203 255 0 0 0 0 7.3 0.1 7.5 7 04/24/2005 08:00:00 0.9 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.9 0.4 204 10 198 255 0 0 0 0 7.3 0 7.5 7.3 04/24/2005 08:10:00 1.3 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 258 19 255 255 0 0 0 0 7.3 0 7.5 7 04/24/2005 08:20:00 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 292 21 304 255 0 0 0 0 7.2 0 7.3 7 04/24/2005 08:30:00 2.3 0.7 3.4 0.7 1.9 0.9 3.4 0.4 1.7 1 3.4 0.4 300 17 313 255 0 0 0 0 7.1 0.1 7.3 7 04/24/2005 08:40:00 2.5 0.5 4.2 0.7 2.3 0.6 4.2 0.4 2 0.6 3.4 0.4 288 14 286 255 0 0 0 0 6.6 0.2 7 6.2 04/24/2005 08:50:00 2.3 0.9 4.2 0.4 1.9 1 4.2 0.4 1.9 1 4.2 0.4 288 17 297 255 0 0 0 0 6.2 0 6.5 6 04/24/2005 09:00:00 1.4 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 274 15 271 255 0 0 0 0 6 0 6.2 5.7 04/24/2005 09:10:00 1.6 0.5 3 0.7 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 281 12 289 255 0 0 0 0 6.2 0 6.5 6.2 04/24/2005 09:20:00 1.3 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 269 27 258 255 0 0 0 0 7.3 0.4 7.8 6.5 04/24/2005 09:30:00 1.6 0.7 3 0.4 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 287 15 315 255 0 0 0 0 7.7 0 8 7.5 04/24/2005 09:40:00 1.7 0.5 3 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 320 15 323 255 0 0 0 0 8 0 8.3 7.8 04/24/2005 09:50:00 2.1 0.5 3.4 0.7 1.7 0.6 3.4 0.4 1.5 0.6 3.4 0.4 308 11 298 255 0 0 0 0 7.8 0 7.8 7.5 04/24/2005 10:00:00 2.3 0.4 3 0.7 1.9 0.5 2.6 0.4 1.8 0.5 2.6 0.4 314 8 307 255 0 0 0 0 7.5 0 7.8 7.3 04/24/2005 10:10:00 1.7 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 308 20 311 255 0 0 0 0 7.6 0 7.8 7.3 04/24/2005 10:20:00 1.8 0.5 3 0.7 1.3 0.6 2.6 0.4 1.2 0.7 3 0.4 349 26 4 255 0 0 0 0 8 0.5 9 7.3 04/24/2005 10:30:00 1.9 0.5 3 0.7 1.4 0.6 2.6 0.4 1.2 0.5 2.6 0.4 0 19 14 255 0 0 0 0 9.7 0.3 10.1 9 04/24/2005 10:40:00 2 0.8 4.2 0.4 1.6 0.9 3.8 0.4 1.4 0.8 3.8 0.4 2 20 4 255 0 0 0 0 10.2 0.4 10.9 9.6 04/24/2005 10:50:00 2.2 0.6 3.8 0.7 1.8 0.7 3.8 0.4 1.4 0.7 3 0.4 4 28 14 255 0 0 0 0 10.9 0 11.1 10.9 04/24/2005 11:00:00 2.4 0.7 3.8 0.4 2.1 0.8 3.4 0.4 1.7 0.8 3 0.4 4 15 355 255 0 0 0 0 11.5 0.4 12.5 10.9 04/24/2005 11:10:00 1.7 0.7 3.4 0.4 1.3 0.8 3.4 0.4 1 0.6 2.6 0.4 354 38 27 255 0 0 0 0 11.4 0.2 12.5 10.9 04/24/2005 11:20:00 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 0.7 0.4 2.3 0.4 346 20 9 255 0 0 0 0 10.9 0.3 11.7 10.6 04/24/2005 11:30:00 2.1 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.4 0.9 3.4 0.4 318 27 322 255 0 0 0 0 11.7 0.3 12.5 11.4 04/24/2005 11:40:00 2.5 0.5 3.8 0.7 2.1 0.5 3.4 0.4 2 0.7 3.4 0.4 345 30 291 255 0 0 0 0 12.1 0.3 12.7 11.7 04/24/2005 11:50:00 2.2 0.6 5.3 0.4 1.7 0.7 4.6 0.4 1.6 0.8 4.6 0.4 340 17 303 255 0 0 0 0 11.5 0.2 12.2 11.1 04/24/2005 12:00:00 2.5 0.8 4.2 0.4 2.2 1 4.2 0.4 2.1 0.9 3.8 0.4 315 17 305 255 0 0 0 0 11.1 0.4 12.2 10.6 04/24/2005 12:10:00 2.8 0.7 4.6 0.4 2.6 0.8 4.2 0.4 2.4 0.9 4.2 0.4 317 22 310 255 0 0 0 0 11.9 0.3 12.7 11.7 04/24/2005 12:20:00 2.8 0.7 4.6 1.1 2.4 0.7 4.2 0.4 2.3 0.8 4.2 0.4 329 24 341 255 0 0 0 0 12.7 0.1 13.3 12.5 04/24/2005 12:30:00 2.3 0.9 4.6 0.4 2 1 4.2 0.4 1.7 1 4.2 0.4 336 30 353 255 0 0 0 0 13 0.3 13.8 12.2 04/24/2005 12:40:00 3 0.8 5.3 0.7 2.8 1 4.9 0.4 2.6 1 4.9 0.4 308 23 275 255 0 0 0 0 12.3 0.4 13.3 11.7 04/24/2005 12:50:00 2.3 0.6 3.8 0.7 2 0.7 3.8 0.4 1.9 1 4.2 0.4 321 23 338 255 0 0 0 0 11.8 0 12.2 11.7 04/24/2005 13:00:00 2.4 1 5.3 0.4 2.3 1.1 5.3 0.4 2 1 4.6 0.4 302 23 302 255 0 0 0 0 11.6 0.1 12.2 11.4 04/24/2005 13:10:00 3.1 1 5.7 0.4 2.9 1.1 5.7 0.4 2.2 1.2 4.9 0.4 311 26 329 255 0 0 0 0 12.1 0.2 12.7 11.7 04/24/2005 13:20:00 4.1 0.8 6.5 2.3 4 0.8 5.7 1.9 3.5 0.9 6.1 1.1 307 15 288 255 0 0 0 0 12.6 0.4 13.3 11.7 04/24/2005 13:30:00 2.8 0.9 4.9 0.4 2.7 1 5.3 0.4 2.4 1 5.7 0.4 295 22 298 255 0 0 0 0 12.6 0 13 12.5 04/24/2005 13:40:00 2.4 1.1 4.9 0.4 2.1 1.2 4.6 0.4 1.7 1 3.8 0.4 295 38 310 255 0 0 0 0 12.3 0.1 12.7 11.9 04/24/2005 13:50:00 3 0.7 5.3 1.1 2.9 0.8 5.3 1.1 2.4 0.8 3.8 0.4 278 26 290 255 0 0 0 0 11.9 0.2 12.5 11.7 04/24/2005 14:00:00 2 1.1 4.2 0.4 1.8 1.1 4.6 0.4 1.4 1.1 3.8 0.4 299 28 263 255 0 0 0 0 12.2 0.2 12.7 11.9 04/24/2005 14:10:00 2.5 1 4.6 0.4 2.3 1 4.9 0.4 1.8 1 3.8 0.4 324 20 325 255 0 0 0 0 12.3 0 12.7 12.2 04/24/2005 14:20:00 2.3 1 4.6 0.4 2 1 4.6 0.4 1.5 1.1 3.8 0.4 322 28 298 255 0 0 0 0 12.5 0.1 13 12.2 04/24/2005 14:30:00 2.4 1 4.9 0.4 2.2 1.1 4.6 0.4 1.8 1.1 4.6 0.4 316 24 310 255 0 0 0 0 12.3 0 12.7 11.9 04/24/2005 14:40:00 2.7 1 5.3 0.4 2.5 1 4.9 0.4 2.2 1 4.9 0.4 311 19 335 255 0 0 0 0 12.2 0.2 12.7 11.9 04/24/2005 14:50:00 2.1 0.9 3.8 0.4 1.9 1 4.2 0.4 1.7 1 4.2 0.4 309 33 303 255 0 0 0 0 13.3 0.4 14.1 12.2 04/24/2005 15:00:00 2.3 1.3 5.3 0.4 2.2 1.3 5.3 0.4 2 1.2 4.2 0.4 288 33 315 255 0 0 0 0 13.5 0.1 14.1 13.3 04/24/2005 15:10:00 2.4 0.9 4.6 0.7 2.1 1 4.6 0.4 1.9 1 4.2 0.4 325 24 314 255 0 0 0 0 13.1 0.3 13.8 12.7 04/24/2005 15:20:00 1.6 0.8 3.4 0.4 1.4 0.7 3 0.4 1.2 0.7 3.4 0.4 340 29 341 255 0 0 0 0 13.7 0.2 14.6 13.3 04/24/2005 15:30:00 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 248 90 297 255 0 0 0 0 14.4 0.2 14.9 13.8 04/24/2005 15:40:00 1.7 1 4.2 0.4 1.5 1 3.8 0.4 1.4 1 3.8 0.4 243 82 297 255 0 0 0 0 14 0.1 14.6 13.8 04/24/2005 15:50:00 2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.7 3 0.4 357 21 24 255 0 0 0 0 14.9 0.4 15.7 14.4 04/24/2005 16:00:00 2.2 0.5 3.8 1.1 2 0.5 3.8 1.1 1.8 0.7 4.2 0.4 19 23 331 255 0 0 0 0 15.2 0.2 16 14.9 04/24/2005 16:10:00 2.2 0.6 3.4 1.1 1.9 0.5 3.4 0.7 1.8 0.7 4.2 0.4 341 12 325 255 0 0 0 0 14 0.4 15.2 13.3 04/24/2005 16:20:00 1.5 0.8 3.4 0.4 1.2 0.7 2.6 0.4 1 0.7 2.6 0.4 327 27 342 255 0 0 0 0 12.9 0.1 13.3 12.7 04/24/2005 16:30:00 1.8 0.7 3 0.4 1.7 0.7 3 0.4 1.3 0.7 2.6 0.4 2 15 12 255 0 0 0 0 13.5 0.1 13.8 13.3 04/24/2005 16:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 2 30 52 255 0 0 0 0 13.9 0 14.4 13.8 04/24/2005 16:50:00 2 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.4 0.8 3.4 0.4 356 22 7 255 0 0 0 0 14.3 0.1 14.9 13.8 04/24/2005 17:00:00 1.8 0.6 3 0.4 1.5 0.6 3 0.4 1.6 0.7 3.4 0.4 342 19 339 255 0 0 0 0 14.2 0.1 14.9 13.8 04/24/2005 17:10:00 2 0.6 3.4 0.4 1.8 0.6 3 0.4 1.5 0.8 3.8 0.4 325 20 355 255 0 0 0 0 14.5 0 14.9 14.4 04/24/2005 17:20:00 1 0.7 2.6 0.4 0.9 0.6 2.3 0.4 0.8 0.6 2.6 0.4 309 82 325 255 0 0 0 0 14.2 0.2 15.2 13.8 04/24/2005 17:30:00 2.3 0.7 3.4 0.4 2.3 0.7 3.4 0.4 1.9 0.7 3.4 0.4 16 16 11 255 0 0 0 0 14.3 0.1 14.9 14.1 04/24/2005 17:40:00 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2.5 0.6 4.2 0.7 11 13 8 255 0 0 0 0 14.2 0.1 14.6 13.8 04/24/2005 17:50:00 2.6 0.6 4.6 1.5 2.6 0.6 4.2 1.5 2.2 0.7 4.2 0.7 9 12 3 255 0 0 0 0 13.9 0 14.4 13.8 04/24/2005 18:00:00 2.8 0.8 4.9 1.1 2.7 0.9 4.9 0.7 2 0.8 3.8 0.4 0 14 6 255 0 0 0 0 14 0.1 14.6 13.8 04/24/2005 18:10:00 3.2 0.7 4.9 1.5 3.1 0.7 4.9 1.5 2.4 0.7 3.8 0.7 7 15 21 255 0 0 0 0 14 0.1 14.6 13.8 04/24/2005 18:20:00 3.5 1.2 6.1 0.4 3.4 1.3 6.5 0.4 2.7 1.3 5.3 0.4 0 20 7 255 0 0 0 0 13.7 0.1 14.4 13.3 04/24/2005 18:30:00 4.1 1 6.1 2.3 4.1 1 6.1 2.3 3.6 1.1 5.7 1.5 16 10 14 255 0 0 0 0 13.2 0.2 13.8 12.7 04/24/2005 18:40:00 3.7 0.9 5.7 1.5 3.6 0.8 5.7 1.9 3 0.8 5.3 1.1 28 15 26 255 0 0 0 0 12.7 0.1 13.3 12.2 04/24/2005 18:50:00 3.2 1.1 5.7 1.5 3.1 1.1 5.7 0.7 2.5 1.2 5.7 0.7 14 11 20 255 0 0 0 0 12.1 0.2 12.7 11.9 04/24/2005 19:00:00 4.1 0.5 5.7 3 4.1 0.5 5.3 3 3.4 0.7 4.9 1.9 20 10 38 255 0 0 0 0 11.6 0 12.2 11.4 04/24/2005 19:10:00 4.4 0.8 6.1 2.6 4.3 0.8 6.1 2.6 3.9 0.8 6.1 2.3 25 11 26 255 0 0 0 0 11 0.2 11.7 10.6 04/24/2005 19:20:00 3.3 0.5 4.9 1.5 3.2 0.5 4.6 1.1 2.8 0.6 4.2 1.5 21 9 24 255 0 0 0 0 10.5 0 11.1 10.3 04/24/2005 19:30:00 2.8 0.6 4.6 1.5 2.8 0.7 4.6 1.5 2.3 0.6 4.2 1.1 37 16 34 255 0 0 0 0 10.2 0 10.3 10.1 04/24/2005 19:40:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.9 2.7 0.7 4.6 1.1 30 9 22 255 0 0 0 0 10 0 10.3 9.8 04/24/2005 19:50:00 3 0.4 4.6 1.5 2.8 0.4 4.2 1.5 2.4 0.5 3.8 1.1 27 11 28 255 0 0 0 0 9.6 0 10.3 9.3 04/24/2005 20:00:00 2.5 0.6 4.2 0.7 2.4 0.7 4.2 0.4 1.9 0.6 3.8 0.4 38 17 20 255 0 0 0 0 9.2 0.1 9.6 9 04/24/2005 20:10:00 2.4 0.5 3.8 1.1 2.3 0.5 3.8 1.1 1.8 0.6 3 0.4 45 12 49 255 0 0 0 0 9 0 9.3 8.8 04/24/2005 20:20:00 2.6 0.5 4.2 1.5 2.5 0.6 4.2 1.1 2.1 0.6 3.8 0.4 39 13 51 255 0 0 0 0 8.7 0 9 8.5 04/24/2005 20:30:00 2 0.7 4.6 0.7 1.9 0.7 4.6 0.7 1.3 0.7 3.4 0.4 46 13 22 255 0 0 0 0 8.4 0 8.8 8 04/24/2005 20:40:00 2.2 0.5 3.4 1.1 2.2 0.5 3.8 1.1 1.5 0.6 2.6 0.4 50 13 35 255 0 0 0 0 7.6 0.2 8.3 7.3 04/24/2005 20:50:00 2.2 0.6 3.8 1.1 2.1 0.6 3.8 0.7 1.3 0.6 3 0.4 52 13 53 255 0 0 0 0 7.3 0.2 7.5 7 04/24/2005 21:00:00 2.7 0.6 4.9 1.5 2.6 0.6 4.9 1.1 2 0.6 3.8 0.7 38 9 25 255 0 0 0 0 6.8 0 7 6.7 04/24/2005 21:10:00 2.4 0.6 3.8 0.7 2.3 0.6 3.8 0.4 1.5 0.7 3 0.4 47 17 32 255 0 0 0 0 6.4 0.2 6.7 6.2 04/24/2005 21:20:00 2.4 0.7 4.2 1.1 2.4 0.7 4.6 0.7 1.7 0.5 3 0.4 64 15 71 255 0 0 0 0 6 0.2 6.5 5.5 04/24/2005 21:30:00 2.7 0.5 4.2 1.5 2.6 0.5 4.2 1.5 1.9 0.5 3.4 0.7 53 14 42 255 0 0 0 0 5.7 0 5.7 5.5 04/24/2005 21:40:00 2.7 0.6 4.2 1.1 2.6 0.7 4.2 0.7 1.9 0.6 3.8 0.4 55 13 49 255 0 0 0 0 5.7 0 6 5.7 04/24/2005 21:50:00 3 0.7 4.9 1.5 3 0.7 4.9 1.5 2.2 0.6 4.2 1.1 58 12 45 255 0 0 0 0 5.7 0 6 5.7 04/24/2005 22:00:00 3.1 0.7 4.9 1.5 3.1 0.7 4.9 1.5 2.2 0.8 4.2 0.4 50 12 74 255 0 0 0 0 6.1 0.1 6.2 5.7 04/24/2005 22:10:00 2.8 0.8 5.3 1.1 2.7 0.8 5.3 1.1 2 0.8 4.6 0.4 60 14 62 255 0 0 0 0 6.1 0 6.2 6 04/24/2005 22:20:00 3.6 0.9 5.7 1.5 3.5 1 5.7 0.7 2.7 0.9 4.9 0.4 53 15 58 255 0 0 0 0 6.2 0 6.2 6 04/24/2005 22:30:00 3.4 0.6 4.9 1.5 3.3 0.7 4.9 1.1 2.4 0.8 4.6 0.7 54 14 58 255 0 0 0 0 6.2 0 6.2 6 04/24/2005 22:40:00 3.8 0.9 6.5 1.1 3.7 1 6.1 0.4 3 1.1 6.1 0.4 47 13 44 255 0 0 0 0 6.2 0 6.2 6 04/24/2005 22:50:00 3.6 0.8 5.7 1.9 3.5 0.9 5.7 1.1 2.9 1 5.3 0.4 54 17 44 255 0 0 0 0 6.2 0 6.5 6 04/24/2005 23:00:00 3.3 0.8 5.3 1.1 3.3 0.8 5.7 1.5 2.3 0.9 4.6 0.4 50 16 49 255 0 0 0 0 5.9 0 6.2 5.7 04/24/2005 23:10:00 3.2 0.7 4.9 1.5 3.1 0.7 4.9 1.5 2.5 0.7 4.2 0.7 49 15 39 255 0 0 0 0 5.9 0 6 5.7 04/24/2005 23:20:00 3.1 0.8 5.3 1.1 3 0.9 5.3 1.1 2.2 0.8 4.6 0.4 52 16 55 255 0 0 0 0 5.7 0 6 5.5 04/24/2005 23:30:00 2.7 0.5 4.2 1.1 2.7 0.6 4.6 1.1 1.9 0.6 3 0.4 69 16 65 255 0 0 0 0 5.3 0.2 5.7 5 04/24/2005 23:40:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.2 0.5 3.4 0.7 71 10 58 255 0 0 0 0 4.8 0.1 5 4.5 04/24/2005 23:50:00 2.9 0.6 4.6 1.9 2.8 0.6 4.6 1.5 2 0.5 3.8 0.7 78 10 79 255 0 0 0 0 4.3 0.2 4.8 4 04/25/2005 00:00:00 2.8 0.7 4.9 1.1 2.7 0.7 5.3 1.1 1.9 0.8 3.8 0.4 69 15 63 255 0 0 0 0 4.1 0.1 4.5 3.8 04/25/2005 00:10:00 2.9 0.8 4.9 0.4 2.8 0.9 4.9 0.4 2 0.9 4.2 0.4 75 12 58 255 0 0 0 0 3.7 0.1 4 3.5 04/25/2005 00:20:00 2.8 0.6 4.2 1.1 2.7 0.6 4.2 1.1 1.8 0.8 3.8 0.4 74 12 64 255 0 0 0 0 3.7 0 4 3.5 04/25/2005 00:30:00 2.6 0.5 4.2 1.1 2.5 0.6 4.2 0.7 1.7 0.5 3.4 0.4 71 12 40 255 0 0 0 0 3.5 0 3.8 3.5 04/25/2005 00:40:00 2.9 0.6 4.2 1.5 2.8 0.6 4.2 1.5 1.8 0.6 3.4 0.4 84 10 77 255 0 0 0 0 3.4 0 3.8 3.3 04/25/2005 00:50:00 3.1 0.5 4.6 1.9 3 0.5 4.6 1.5 2.1 0.7 3.8 0.4 77 12 69 255 0 0 0 0 3.3 0 3.8 3.3 04/25/2005 01:00:00 2.8 0.6 4.6 1.5 2.7 0.6 4.6 1.1 1.9 0.6 3.8 0.4 78 11 74 255 0 0 0 0 3.2 0.1 3.8 2.8 04/25/2005 01:10:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.5 1.6 0.5 2.6 0.4 79 8 66 255 0 0 0 0 3.4 0.1 3.8 3 04/25/2005 01:20:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.4 0.5 2.6 0.4 76 7 86 255 0 0 0 0 2.8 0.3 3.5 2.3 04/25/2005 01:30:00 2.3 0.4 3.4 0.7 2.2 0.5 3 0.4 0.8 0.4 1.9 0.4 82 12 79 255 0 0 0 0 2 0.1 2.6 1.8 04/25/2005 01:40:00 2 0.5 2.6 0.4 1.8 0.5 2.6 0.4 0.6 0.3 1.5 0.4 93 8 91 255 0 0 0 0 1.8 0 2.3 1.6 04/25/2005 01:50:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 0.4 0.2 1.1 0.4 68 17 90 255 0 0 0 0 1.5 0.2 1.8 1.4 04/25/2005 02:00:00 2.1 0.2 2.6 1.5 2 0.3 2.6 1.5 0.7 0.4 1.5 0.4 55 11 69 255 0 0 0 0 1.2 0 1.4 0.9 04/25/2005 02:10:00 1.5 0.3 2.6 0.7 1.3 0.3 2.3 0.4 0.4 0.2 1.1 0.4 66 19 66 255 0 0 0 0 0.9 0 1.1 0.9 04/25/2005 02:20:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.7 0.4 50 2 57 255 0 0 0 0 0.8 0 0.9 0.7 04/25/2005 02:30:00 1.4 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.6 0.3 1.5 0.4 61 13 80 255 0 0 0 0 0.5 0 0.7 0.2 04/25/2005 02:40:00 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.4 0.7 0.4 1.5 0.4 62 13 48 255 0 0 0 0 0.5 0 0.7 0.4 04/25/2005 02:50:00 1.2 0.2 1.9 0.7 1 0.3 1.5 0.4 0.4 0 0.4 0.4 57 0 58 255 0 0 0 0 0.4 0 0.7 0.2 04/25/2005 03:00:00 1.3 0.2 1.9 0.7 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 57 0 57 255 0 0 0 0 0.1 0 0.4 -0.1 04/25/2005 03:10:00 0.9 0.2 1.5 0.4 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 57 0 57 255 0 0 0 0 0 0 0.2 -0.1 04/25/2005 03:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 57 0 57 255 0 0 0 0 -0.2 0 -0.1 -0.3 04/25/2005 03:30:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 0.4 0 0.4 0.4 48 7 57 255 0 0 0 0 -0.2 0 -0.1 -0.3 04/25/2005 03:40:00 1.1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 37 1 41 255 0 0 0 0 -0.3 0.1 0.2 -0.5 04/25/2005 03:50:00 1.2 0.3 1.9 0.7 1 0.3 1.5 0.4 0.4 0 0.4 0.4 26 3 25 255 0 0 0 0 -0.4 0 0.2 -0.5 04/25/2005 04:00:00 0.9 0.3 1.5 0.4 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 25 0 25 255 0 0 0 0 -0.4 0 0.2 -0.5 04/25/2005 04:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 25 255 0 0 0 0 -0.5 0 -0.5 -0.5 04/25/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 255 255 0 0 0 0 -0.6 0 -0.5 -0.7 04/25/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 25 0 255 255 0 0 0 0 -0.7 0 -0.3 -0.7 04/25/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 255 255 0 0 0 0 -0.7 0 -0.5 -0.7 04/25/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 15 255 255 0 0 0 0 -0.9 0 -0.7 -1 04/25/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 255 255 0 0 0 0 -0.9 0 -0.7 -1 04/25/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 255 255 0 0 0 0 -0.9 0 -0.7 -1 04/25/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 22 255 255 0 0 0 0 -0.9 0.1 -0.7 -1 04/25/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 255 255 0 0 0 0 -0.8 0 -0.5 -0.7 04/25/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 255 255 0 0 0 0 -0.3 0.1 -0.1 -0.7 04/25/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 255 255 0 0 0 0 0.1 0.1 0.2 -0.1 04/25/2005 06:00:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 323 56 339 255 0 0 0 0 0.7 0.2 0.9 0.2 04/25/2005 06:10:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 359 11 339 255 0 0 0 0 0.9 0 1.4 0.9 04/25/2005 06:20:00 1.4 0.2 1.9 1.1 1.2 0.2 1.9 0.7 0.4 0 0.4 0.4 6 0 6 255 0 0 0 0 1.5 0.3 2.1 1.1 04/25/2005 06:30:00 1.1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 6 0 6 255 0 0 0 0 2.3 0 2.3 2.1 04/25/2005 06:40:00 0.9 0.3 1.5 0.4 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 6 0 6 255 0 0 0 0 2.9 0.5 3.8 2.3 04/25/2005 06:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 19 16 10 255 0 0 0 0 4.3 0.4 5 3.8 04/25/2005 07:00:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 38 4 40 255 0 0 0 0 5.6 0.3 6.2 5 04/25/2005 07:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 30 17 35 255 0 0 0 0 6.2 0 6.5 6.2 04/25/2005 07:20:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 12 5 18 255 0 0 0 0 6.7 0.1 7 6.5 04/25/2005 07:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 10 7 35 255 0 0 0 0 7.2 0.2 7.5 6.7 04/25/2005 07:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 24 8 33 255 0 0 0 0 7.4 0 7.8 7.3 04/25/2005 07:50:00 0.8 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 15 10 37 255 0 0 0 0 8 0.1 8.3 7.5 04/25/2005 08:00:00 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 22 8 24 255 0 0 0 0 8.2 0.1 8.5 8 04/25/2005 08:10:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.4 20 8 12 255 0 0 0 0 8.8 0.1 9 8.5 04/25/2005 08:20:00 1.6 0.4 2.6 0.7 1.5 0.4 2.3 0.4 1.1 0.4 2.3 0.4 23 9 30 255 0 0 0 0 9.3 0 9.6 9 04/25/2005 08:30:00 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 8 17 19 255 0 0 0 0 9.6 0.1 10.3 9.3 04/25/2005 08:40:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 355 35 37 255 0 0 0 0 10.2 0.2 10.9 9.8 04/25/2005 08:50:00 1.3 0.6 2.6 0.4 1.2 0.5 2.6 0.4 1.1 0.6 2.6 0.4 331 22 299 255 0 0 0 0 10.5 0.2 11.4 10.3 04/25/2005 09:00:00 1 0.5 2.6 0.4 0.9 0.4 2.3 0.4 0.7 0.4 2.3 0.4 352 14 355 255 0 0 0 0 11.3 0.3 12.2 10.9 04/25/2005 09:10:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.2 0.4 2.3 0.4 310 14 324 255 0 0 0 0 11.7 0 11.9 11.4 04/25/2005 09:20:00 1.6 0.6 3 0.4 1.5 0.6 2.6 0.4 1.2 0.5 2.6 0.4 310 18 294 255 0 0 0 0 12.1 0.3 12.7 11.7 04/25/2005 09:30:00 1.7 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1.5 0.5 3 0.4 310 12 309 255 0 0 0 0 12.7 0 13.3 12.5 04/25/2005 09:40:00 1.6 0.6 3.4 0.4 1.5 0.6 3 0.4 1.3 0.7 3 0.4 305 18 321 255 0 0 0 0 12.7 0 13.3 12.5 04/25/2005 09:50:00 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.6 0.4 326 18 312 255 0 0 0 0 13.2 0.2 13.8 12.7 04/25/2005 10:00:00 1.7 0.5 3 0.4 1.5 0.5 3 0.4 1.4 0.6 2.6 0.4 321 23 322 255 0 0 0 0 13.7 0.1 14.1 13 04/25/2005 10:10:00 1.9 0.6 3.4 0.4 1.8 0.6 3 0.4 1.6 0.7 3 0.4 333 33 10 255 0 0 0 0 14.2 0 14.9 13.8 04/25/2005 10:20:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 1.1 0.5 2.3 0.4 347 22 349 255 0 0 0 0 14.8 0.4 15.7 14.4 04/25/2005 10:30:00 1.8 0.6 3.8 0.4 1.6 0.6 3.8 0.4 1.5 0.5 3.4 0.4 354 22 350 255 0 0 0 0 15.2 0.1 15.7 14.9 04/25/2005 10:40:00 1.9 0.5 3 0.7 1.9 0.6 3 0.4 1.7 0.6 2.6 0.4 8 15 4 255 0 0 0 0 15.3 0 15.7 15.2 04/25/2005 10:50:00 2.1 0.4 3.4 1.1 1.9 0.4 3 1.1 1.6 0.6 3 0.4 351 17 340 255 0 0 0 0 15.7 0 16 15.7 04/25/2005 11:00:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 356 18 8 255 0 0 0 0 16 0.3 16.6 15.5 04/25/2005 11:10:00 1.8 0.5 3 0.4 1.7 0.5 3 0.7 1.4 0.5 2.6 0.4 4 13 2 255 0 0 0 0 16.5 0 16.8 16.3 04/25/2005 11:20:00 1.4 0.6 3 0.4 1.3 0.6 3 0.4 1.2 0.7 3 0.4 356 47 278 255 0 0 0 0 16.8 0 17.1 16.6 04/25/2005 11:30:00 1 0.6 3 0.4 0.9 0.6 3.4 0.4 0.9 0.5 2.3 0.4 276 17 274 255 0 0 0 0 16.6 0.4 17.7 16.3 04/25/2005 11:40:00 1.5 0.6 3 0.4 1.4 0.7 2.6 0.4 1.3 0.7 3 0.4 55 43 38 255 0 0 0 0 17.6 0.1 18.2 17.1 04/25/2005 11:50:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 35 29 34 255 0 0 0 0 17.8 0 18.2 17.4 04/25/2005 12:00:00 1.4 0.8 3 0.4 1.3 0.7 3 0.4 1.3 0.7 3 0.4 20 36 333 255 0 0 0 0 17.9 0.2 18.5 17.4 04/25/2005 12:10:00 1.6 0.9 3.8 0.4 1.5 0.8 3.8 0.4 1.3 0.8 4.2 0.4 4 35 8 255 0 0 0 0 18.4 0.2 19.4 18 04/25/2005 12:20:00 1.1 0.9 3.8 0.4 1.1 0.9 3.8 0.4 0.9 0.8 3.4 0.4 51 76 2 255 0 0 0 0 18.8 0 19.4 18.5 04/25/2005 12:30:00 1.7 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.4 0.7 2.6 0.4 320 33 323 255 0 0 0 0 18.9 0.1 19.4 18.5 04/25/2005 12:40:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.6 0.8 3 0.4 37 43 16 255 0 0 0 0 19.4 0 19.7 19.1 04/25/2005 12:50:00 1.9 0.7 4.2 0.4 1.8 0.7 3.4 0.4 1.5 0.7 3.4 0.4 4 22 12 255 0 0 0 0 20 0.3 20.5 19.4 04/25/2005 13:00:00 1.6 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.4 0.8 3.4 0.4 40 72 34 255 0 0 0 0 20.3 0 20.5 20.3 04/25/2005 13:10:00 1.7 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 37 45 338 255 0 0 0 0 20.6 0 21.1 20.3 04/25/2005 13:20:00 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 245 102 216 255 0 0 0 0 20.3 0.2 21.1 20 04/25/2005 13:30:00 2 0.9 4.6 0.4 2 0.9 4.2 0.4 1.7 0.9 4.2 0.4 14 38 64 255 0 0 0 0 21 0 21.4 20.8 04/25/2005 13:40:00 2.4 0.8 4.9 0.7 2.3 0.8 4.9 0.7 1.9 1 4.9 0.4 45 43 64 255 0 0 0 0 21.6 0.1 22.3 21.1 04/25/2005 13:50:00 1.9 1.1 4.6 0.4 1.8 1.1 4.6 0.4 1.6 1.1 4.2 0.4 46 51 45 255 0 0 0 0 21.6 0.2 22.3 21.1 04/25/2005 14:00:00 1.5 0.8 3.4 0.4 1.5 0.8 4.2 0.4 1.3 0.8 3.4 0.4 20 35 56 255 0 0 0 0 21.9 0.1 22.6 21.7 04/25/2005 14:10:00 1.8 0.9 3.4 0.4 1.8 0.9 3.4 0.4 1.6 0.9 3.4 0.4 32 66 16 255 0 0 0 0 21.9 0 22.3 21.7 04/25/2005 14:20:00 2.2 1 4.6 0.4 2 0.9 4.2 0.4 1.8 1 4.6 0.4 340 23 347 255 0 0 0 0 22 0.1 22.3 21.7 04/25/2005 14:30:00 2.2 0.9 4.2 0.4 2 0.8 3.8 0.4 1.7 1 3.8 0.4 337 38 358 255 0 0 0 0 22.1 0.2 22.6 21.7 04/25/2005 14:40:00 2.6 0.8 4.9 0.7 2.4 0.8 4.6 0.7 2.1 0.8 4.2 0.4 348 19 327 255 0 0 0 0 21.4 0.1 21.7 21.1 04/25/2005 14:50:00 2.7 0.7 4.6 1.1 2.6 0.8 4.9 0.7 2.2 0.7 3.8 0.4 353 10 358 255 0 0 0 0 21.6 0.2 22.3 21.1 04/25/2005 15:00:00 2.4 0.8 4.6 0.4 2.2 0.8 4.2 0.4 1.6 0.7 3.8 0.4 348 17 347 255 0 0 0 0 22.7 0.3 23.5 22 04/25/2005 15:10:00 3 0.6 4.6 1.5 2.9 0.6 4.2 0.7 2.6 0.9 4.6 0.4 296 22 272 255 0 0 0 0 22.1 0.4 23.2 21.4 04/25/2005 15:20:00 2.5 0.8 4.6 0.4 2.4 0.8 4.6 0.4 2.1 0.7 4.2 0.7 276 26 262 255 0 0 0 0 22.1 0.2 22.9 21.4 04/25/2005 15:30:00 2.9 0.8 5.3 1.1 2.9 0.8 4.9 0.7 2.5 0.8 4.9 0.7 288 27 304 255 0 0 0 0 21.8 0.2 22.9 21.4 04/25/2005 15:40:00 1.8 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.5 0.7 3 0.4 252 49 286 255 0 0 0 0 21.7 0.1 22.3 21.4 04/25/2005 15:50:00 2 0.9 4.6 0.4 2 0.9 4.2 0.4 1.8 0.9 4.2 0.4 290 17 286 255 0 0 0 0 21.4 0.1 22 21.1 04/25/2005 16:00:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 280 49 269 255 0 0 0 0 21.6 0.1 22.3 21.1 04/25/2005 16:10:00 1.2 0.8 3.4 0.4 1.3 0.8 3 0.4 1.1 0.9 3.8 0.4 326 51 321 255 0 0 0 0 21.7 0.1 22.3 21.1 04/25/2005 16:20:00 1.7 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.4 0.7 3 0.4 287 20 279 255 0 0 0 0 21.1 0 21.7 21.1 04/25/2005 16:30:00 1.7 1.1 4.2 0.4 1.6 1 3.8 0.4 1.2 0.9 3.8 0.4 295 38 335 255 0 0 0 0 20.9 0 21.4 20.8 04/25/2005 16:40:00 2.2 0.7 3.4 0.4 2.1 0.6 3.4 0.7 1.6 0.8 3.8 0.4 335 23 325 255 0 0 0 0 20.7 0.1 21.4 20.5 04/25/2005 16:50:00 1.5 0.6 3.4 0.4 1.4 0.7 3.4 0.4 0.9 0.6 2.6 0.4 295 36 266 255 0 0 0 0 20.5 0 20.8 20.5 04/25/2005 17:00:00 2.2 0.8 3.8 0.4 2.2 0.8 4.2 0.4 1.5 0.8 3.4 0.4 273 19 248 255 0 0 0 0 20.3 0 20.5 20.3 04/25/2005 17:10:00 2.6 0.8 4.2 0.4 2.5 0.8 4.2 0.4 2 1 4.2 0.4 289 26 287 255 0 0 0 0 20.3 0.1 20.5 20 04/25/2005 17:20:00 2.8 0.7 4.6 1.1 2.8 0.7 4.6 1.1 2.1 0.7 4.2 0.4 312 20 315 255 0 0 0 0 20.2 0 20.5 20 04/25/2005 17:30:00 2.8 0.6 4.6 0.7 2.7 0.7 4.6 0.4 2.3 0.9 4.2 0.4 310 17 313 255 0 0 0 0 20.3 0 20.8 20 04/25/2005 17:40:00 3 0.6 4.2 1.1 2.9 0.7 4.2 1.1 2.8 0.7 4.6 0.7 305 15 301 255 0 0 0 0 20.1 0 20.5 19.7 04/25/2005 17:50:00 2.4 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2.1 0.8 3.8 0.4 302 15 294 255 0 0 0 0 19.8 0 20.5 19.7 04/25/2005 18:00:00 2.2 0.5 3.8 0.7 1.9 0.5 3.4 0.7 1.4 0.6 3 0.4 339 18 333 255 0 0 0 0 19.8 0 20.3 19.7 04/25/2005 18:10:00 1.2 0.6 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 336 17 290 255 0 0 0 0 19.6 0.1 20 19.4 04/25/2005 18:20:00 1.3 0.5 2.3 0.4 1.1 0.4 1.9 0.4 1 0.6 2.6 0.4 348 12 343 255 0 0 0 0 19.5 0 20 19.4 04/25/2005 18:30:00 1.9 0.5 3 0.4 1.8 0.5 3 0.4 1.5 0.7 3 0.4 316 22 298 255 0 0 0 0 19.1 0.1 19.7 19.1 04/25/2005 18:40:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 297 9 291 255 0 0 0 0 19.1 0 19.4 19.1 04/25/2005 18:50:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 258 30 226 255 0 0 0 0 18.9 0.1 19.4 18.5 04/25/2005 19:00:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 224 24 216 255 0 0 0 0 18.4 0.1 19.1 18 04/25/2005 19:10:00 0.9 0.6 3 0.4 0.9 0.6 3 0.4 0.7 0.5 2.3 0.4 252 32 231 255 0 0 0 0 18 0 18.5 17.7 04/25/2005 19:20:00 1.1 0.7 3.4 0.4 1.1 0.7 3.4 0.4 0.7 0.5 1.9 0.4 22 61 99 255 0 0 0 0 17.7 0 18 17.4 04/25/2005 19:30:00 0.8 0.5 2.6 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 60 36 107 255 0 0 0 0 17.3 0.2 17.7 16.8 04/25/2005 19:40:00 1.1 0.7 2.6 0.4 1.1 0.7 3 0.4 0.7 0.5 3 0.4 120 27 170 255 0 0 0 0 16.7 0 16.8 16.6 04/25/2005 19:50:00 1.4 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.7 3 0.4 93 16 100 255 0 0 0 0 16.2 0.1 16.6 16 04/25/2005 20:00:00 3.4 1 5.3 0.7 3.4 1 5.3 0.7 2.8 0.9 4.6 0.4 100 12 110 255 0 0 0 0 16.6 0.2 17.1 16.3 04/25/2005 20:10:00 3.9 0.8 6.1 2.3 3.9 0.7 5.7 2.3 3.2 0.8 5.3 1.1 103 13 70 255 0 0 0 0 16.6 0 17.1 16.3 04/25/2005 20:20:00 4.1 0.8 6.1 1.9 4.1 0.8 6.5 1.5 3.4 0.8 5.7 1.5 91 12 93 255 0 0 0 0 16.1 0 16.6 16 04/25/2005 20:30:00 4.4 0.8 6.5 2.3 4.3 0.8 6.5 2.6 3.6 0.8 5.7 1.9 99 10 94 255 0 0 0 0 15.7 0 16.3 15.7 04/25/2005 20:40:00 4.3 0.7 6.1 2.6 4.2 0.8 6.1 2.3 3.4 0.8 5.3 1.5 95 12 100 255 0 0 0 0 15.5 0 15.7 15.2 04/25/2005 20:50:00 4.4 1 8 1.9 4.3 1 8 2.3 3.6 0.9 6.1 1.1 96 12 102 255 0 0 0 0 15.1 0 15.5 15.2 04/25/2005 21:00:00 4.1 0.9 6.5 2.3 4.1 0.9 6.5 1.9 3.2 1 5.7 1.1 90 12 102 255 0 0 0 0 14.9 0 15.5 14.6 04/25/2005 21:10:00 4.2 0.9 6.8 1.9 4.2 0.9 6.5 1.9 3.4 0.8 5.7 1.5 95 14 81 255 0 0 0 0 14.8 0 15.5 14.6 04/25/2005 21:20:00 4.2 0.9 6.5 2.3 4.2 0.9 6.8 2.6 3.5 0.8 5.7 1.5 91 12 73 255 0 0 0 0 14.4 0.1 15.2 14.4 04/25/2005 21:30:00 4.4 0.9 6.5 1.9 4.3 0.9 6.8 1.9 3.5 0.9 6.1 1.1 95 14 95 255 0 0 0 0 14.1 0 14.6 13.8 04/25/2005 21:40:00 4.3 1 6.5 1.5 4.2 0.9 6.1 1.9 3.5 1 5.3 0.7 94 12 86 255 0 0 0 0 13.9 0 14.4 13.8 04/25/2005 21:50:00 4.6 1 8 1.9 4.5 1 7.6 1.9 3.8 1 6.5 1.5 94 13 83 255 0 0 0 0 13.8 0 14.4 13.5 04/25/2005 22:00:00 4.1 0.8 6.5 2.3 4.1 0.8 6.5 1.9 3.4 0.8 6.1 1.5 93 14 85 255 0 0 0 0 13.8 0 14.4 13.5 04/25/2005 22:10:00 4.1 0.8 6.1 1.9 4 0.8 5.7 2.3 3.4 0.8 5.3 1.5 94 14 81 255 0 0 0 0 13.5 0 14.1 13.3 04/25/2005 22:20:00 4.1 0.7 6.1 2.3 4.1 0.7 5.7 1.9 3.2 0.7 4.9 1.1 93 13 100 255 0 0 0 0 13.3 0.1 13.8 13 04/25/2005 22:30:00 3.6 0.7 5.7 1.9 3.5 0.7 5.7 1.9 2.7 0.6 4.9 1.5 96 12 116 255 0 0 0 0 12.9 0 13.5 12.7 04/25/2005 22:40:00 3.5 0.6 5.3 1.9 3.4 0.7 5.3 1.9 2.7 0.7 4.6 1.1 104 13 95 255 0 0 0 0 12.4 0.1 12.7 12.2 04/25/2005 22:50:00 3.7 0.6 5.3 2.6 3.6 0.6 5.7 2.3 2.8 0.7 4.9 1.5 98 10 84 255 0 0 0 0 12.1 0.1 12.5 11.7 04/25/2005 23:00:00 3.6 0.6 4.9 1.9 3.6 0.7 5.3 1.5 2.6 0.8 4.6 1.1 97 10 99 255 0 0 0 0 11.7 0 12.2 11.7 04/25/2005 23:10:00 3.4 0.6 4.9 1.9 3.3 0.6 4.9 1.9 2.5 0.6 4.2 0.4 100 11 92 255 0 0 0 0 11.3 0 11.9 11.1 04/25/2005 23:20:00 3.4 0.6 5.3 1.9 3.3 0.6 4.9 1.9 2.4 0.8 4.2 0.4 98 11 93 255 0 0 0 0 10.9 0.1 11.4 10.6 04/25/2005 23:30:00 3.2 0.7 4.9 1.5 3.1 0.7 4.9 1.1 2.2 0.6 4.9 0.4 97 11 115 255 0 0 0 0 10.5 0 10.6 10.3 04/25/2005 23:40:00 3.4 0.6 4.9 2.3 3.3 0.5 4.9 1.9 2.6 0.7 4.2 0.7 93 10 94 255 0 0 0 0 10.5 0 10.9 10.3 04/25/2005 23:50:00 3.8 0.6 4.9 2.6 3.8 0.6 5.3 2.3 2.9 0.7 4.6 1.1 94 9 92 255 0 0 0 0 10.1 0 10.6 9.8 04/26/2005 00:00:00 3.7 0.5 4.9 2.3 3.7 0.5 4.9 1.9 2.9 0.6 4.2 1.1 100 9 102 255 0 0 0 0 10.3 0 10.6 9.8 04/26/2005 00:10:00 3.8 0.6 5.3 2.3 3.7 0.6 5.3 1.9 2.7 0.6 4.6 0.7 100 12 121 255 0 0 0 0 10.3 0 10.6 10.3 04/26/2005 00:20:00 3.6 0.6 4.9 1.9 3.6 0.6 5.3 1.9 2.5 0.6 4.6 1.1 105 11 104 255 0 0 0 0 10 0.1 10.3 9.6 04/26/2005 00:30:00 3.5 0.7 5.3 1.5 3.4 0.7 5.3 1.5 2.4 0.7 4.2 0.7 107 12 101 255 0 0 0 0 9.7 0.1 9.8 9.6 04/26/2005 00:40:00 3.8 0.8 6.1 1.5 3.8 0.8 5.7 1.5 3 0.9 4.9 0.7 110 13 113 255 0 0 0 0 9.8 0 10.1 9.6 04/26/2005 00:50:00 4.2 0.7 5.7 2.3 4.1 0.7 5.7 2.3 3.3 0.8 4.9 1.1 107 10 99 255 0 0 0 0 9.8 0 9.8 9.6 04/26/2005 01:00:00 4.5 0.7 6.1 1.9 4.4 0.7 6.1 1.9 3.3 0.7 5.3 1.5 103 10 108 255 0 0 0 0 9.8 0 9.8 9.6 04/26/2005 01:10:00 4.4 0.7 6.1 2.3 4.3 0.6 6.1 2.3 3.3 0.8 5.3 1.5 102 10 106 255 0 0 0 0 9.7 0 9.8 9.6 04/26/2005 01:20:00 4.1 0.7 6.5 2.6 4 0.7 6.1 1.9 3.1 0.7 4.9 1.5 102 11 100 255 0 0 0 0 9.6 0 9.8 9.6 04/26/2005 01:30:00 4.4 0.8 6.1 2.3 4.3 0.8 6.1 2.6 3.5 0.8 5.7 1.9 98 10 83 255 0 0 0 0 9.6 0 9.8 9.6 04/26/2005 01:40:00 4 0.8 5.7 2.3 3.8 0.8 5.3 2.3 2.8 0.8 5.3 1.1 106 13 106 255 0 0 0 0 9.5 0 9.6 9.3 04/26/2005 01:50:00 3.9 0.6 5.3 1.9 3.8 0.6 4.9 1.5 2.8 0.8 4.9 0.4 106 11 104 255 0 0 0 0 9.4 0 9.6 9 04/26/2005 02:00:00 4 0.9 6.5 1.9 4 0.9 6.1 1.9 3.1 1 5.3 0.7 111 15 118 255 0 0 0 0 9.2 0 9.3 9 04/26/2005 02:10:00 4.7 0.7 6.5 2.3 4.7 0.7 6.1 2.3 3.6 0.8 5.7 1.5 110 12 121 255 0 0 0 0 9.2 0 9.3 9 04/26/2005 02:20:00 4.1 0.7 5.7 2.3 4.1 0.8 5.7 2.3 3 0.9 5.7 1.1 106 13 85 255 0 0 0 0 9.2 0 9.3 9 04/26/2005 02:30:00 4.3 0.7 6.1 2.6 4.2 0.7 6.1 2.3 3.3 0.7 5.3 1.1 101 9 104 255 0 0 0 0 8.9 0 9 8.8 04/26/2005 02:40:00 3.7 0.8 5.3 1.9 3.6 0.8 5.7 1.5 2.8 0.7 4.6 1.1 108 13 91 255 0 0 0 0 8.7 0 8.8 8.5 04/26/2005 02:50:00 3.5 0.6 4.6 2.3 3.4 0.6 4.6 1.9 2.4 0.6 3.8 0.7 114 10 107 255 0 0 0 0 8.2 0.2 8.5 7.8 04/26/2005 03:00:00 3.9 0.6 5.3 2.3 3.8 0.7 5.3 1.9 2.8 0.7 4.6 1.1 115 11 101 255 0 0 0 0 7.6 0 7.8 7.5 04/26/2005 03:10:00 4 0.6 5.7 2.3 3.9 0.7 5.7 2.3 2.9 0.7 4.6 1.1 114 12 97 255 0 0 0 0 7.8 0 8 7.5 04/26/2005 03:20:00 3.5 0.7 5.3 1.9 3.4 0.7 5.3 1.5 2.5 0.7 4.6 1.1 109 13 113 255 0 0 0 0 7.9 0 8 7.8 04/26/2005 03:30:00 3.7 0.8 5.7 1.9 3.5 0.8 5.3 1.9 2.7 0.8 4.9 0.7 117 12 107 255 0 0 0 0 7.6 0 7.8 7.5 04/26/2005 03:40:00 3.7 0.9 5.3 1.5 3.6 0.9 5.3 1.1 2.6 0.8 5.3 0.7 117 15 128 255 0 0 0 0 7.8 0.2 8.3 7.5 04/26/2005 03:50:00 3.6 1 6.1 1.1 3.6 1 5.7 0.7 2.7 0.8 5.3 1.1 114 14 110 255 0 0 0 0 7.8 0 8 7.5 04/26/2005 04:00:00 4.9 0.9 6.8 2.3 4.8 0.9 6.8 2.6 3.8 0.9 6.5 1.5 115 13 109 255 0 0 0 0 8.3 0.2 8.5 7.8 04/26/2005 04:10:00 4.3 0.9 6.5 1.9 4.3 0.9 6.5 1.9 3.4 0.9 5.7 1.1 109 14 124 255 0 0 0 0 8.4 0 8.8 8.3 04/26/2005 04:20:00 3.4 0.8 5.3 1.1 3.3 0.8 5.3 0.7 2.4 0.9 4.9 0.7 103 13 95 255 0 0 0 0 8.2 0.1 8.5 8 04/26/2005 04:30:00 2.8 0.5 4.2 1.1 2.6 0.6 4.2 0.7 1.8 0.6 3.4 0.4 105 11 86 255 0 0 0 0 7.8 0 8 7.5 04/26/2005 04:40:00 3 0.7 4.9 1.5 2.8 0.7 4.6 1.1 1.8 0.7 4.2 0.4 110 13 95 255 0 0 0 0 7.3 0.1 7.5 7 04/26/2005 04:50:00 3.5 0.6 4.9 1.5 3.4 0.6 4.6 1.5 2.6 0.6 4.6 1.1 107 9 108 255 0 0 0 0 7.3 0 7.5 7 04/26/2005 05:00:00 3.9 0.6 4.9 1.9 3.8 0.6 4.9 1.5 3 0.7 4.9 1.1 103 8 100 255 0 0 0 0 7.3 0 7.3 7 04/26/2005 05:10:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.6 3.3 0.6 4.9 1.9 101 7 111 255 0 0 0 0 7.4 0.1 7.8 7.3 04/26/2005 05:20:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.5 2.5 0.6 4.2 1.1 113 11 97 255 0 0 0 0 7.6 0 7.8 7.5 04/26/2005 05:30:00 2.7 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.9 0.6 3.4 0.4 120 14 128 255 0 0 0 0 7.7 0 8 7.5 04/26/2005 05:40:00 2.4 0.7 4.2 0.7 2.3 0.7 4.2 0.4 1.5 0.7 3 0.4 111 14 124 255 0 0 0 0 8.3 0.1 8.5 8 04/26/2005 05:50:00 3 0.6 4.2 1.1 2.9 0.6 4.6 1.1 2.1 0.7 3.8 0.4 101 13 88 255 0 0 0 0 8.7 0.2 9 8.5 04/26/2005 06:00:00 2.9 0.6 4.2 1.5 2.8 0.7 4.6 1.1 2.2 0.7 3.8 0.4 91 9 98 255 0 0 0 0 9.2 0.2 9.6 9 04/26/2005 06:10:00 1.9 0.5 3.4 0.7 1.8 0.6 3 0.7 1.1 0.6 2.6 0.4 95 11 94 255 0 0 0 0 9.6 0 9.8 9.6 04/26/2005 06:20:00 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.3 0.6 3 0.4 89 22 88 255 0 0 0 0 10.2 0.1 10.6 9.8 04/26/2005 06:30:00 0.7 0.5 2.6 0.4 0.6 0.4 2.6 0.4 1 0.5 2.6 0.4 295 16 280 255 0 0 0 0 9.8 0.4 10.3 9 04/26/2005 06:40:00 0.5 0.3 1.1 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 279 6 291 255 0 0 0 0 9.2 0.1 9.6 9 04/26/2005 06:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 291 6 292 255 0 0 0 0 9.6 0.2 10.1 9.3 04/26/2005 07:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 324 15 303 255 0 0 0 0 10.3 0.1 10.9 9.8 04/26/2005 07:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 359 26 337 255 0 0 0 0 10.7 0.1 11.4 10.3 04/26/2005 07:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.3 1.5 0.4 25 19 6 255 0 0 0 0 10.1 0 10.6 9.8 04/26/2005 07:30:00 1.3 0.5 2.3 0.4 1 0.6 2.3 0.4 1 0.8 2.6 0.4 323 24 305 255 0 0 0 0 10.2 0.1 10.6 9.8 04/26/2005 07:40:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 309 7 290 255 0 0 0 0 10.8 0.4 11.7 10.3 04/26/2005 07:50:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.4 2.3 0.4 299 22 286 255 0 0 0 0 11.7 0.2 12.2 11.1 04/26/2005 08:00:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 351 15 319 255 0 0 0 0 12.3 0 12.7 11.9 04/26/2005 08:10:00 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1.1 0.3 1.9 0.4 10 10 335 255 0 0 0 0 12.7 0 13.3 12.5 04/26/2005 08:20:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 11 16 352 255 0 0 0 0 12.9 0 13.3 12.7 04/26/2005 08:30:00 0.7 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 18 11 15 255 0 0 0 0 13.3 0.2 13.8 12.7 04/26/2005 08:40:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1.4 0.4 2.6 0.4 7 10 355 255 0 0 0 0 13.6 0.1 14.4 13.3 04/26/2005 08:50:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 355 10 15 255 0 0 0 0 13.9 0.1 14.6 13.5 04/26/2005 09:00:00 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 5 14 349 255 0 0 0 0 14.1 0.1 14.6 13.8 04/26/2005 09:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 19 18 49 255 0 0 0 0 14.2 0 14.6 13.8 04/26/2005 09:20:00 1.1 0.7 3 0.4 1.1 0.7 2.6 0.4 1 0.6 3 0.4 35 47 3 255 0 0 0 0 15 0.2 15.5 14.6 04/26/2005 09:30:00 1.3 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.5 2.3 0.4 19 22 35 255 0 0 0 0 15 0 15.5 14.9 04/26/2005 09:40:00 1.8 0.5 3 0.4 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 5 24 340 255 0 0 0 0 15.5 0.1 15.7 15.2 04/26/2005 09:50:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1 0.6 2.3 0.4 351 36 284 255 0 0 0 0 15.7 0 16 15.5 04/26/2005 10:00:00 1.6 0.5 3 0.7 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 12 17 34 255 0 0 0 0 15.7 0 16 15.5 04/26/2005 10:10:00 1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.9 0.6 2.6 0.4 12 24 23 255 0 0 0 0 16.4 0.1 16.8 16 04/26/2005 10:20:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 7 20 23 255 0 0 0 0 16.8 0.2 17.1 16.6 04/26/2005 10:30:00 1.5 0.7 2.6 0.4 1.4 0.7 3 0.4 1.3 0.6 2.6 0.4 23 26 64 255 0 0 0 0 17.1 0 17.1 16.8 04/26/2005 10:40:00 1.8 0.8 4.2 0.4 1.7 0.7 3.8 0.4 1.4 0.7 3 0.4 340 43 306 255 0 0 0 0 17.5 0.3 18.5 17.1 04/26/2005 10:50:00 2.5 0.6 4.2 1.1 2.4 0.6 4.2 0.7 2.1 0.7 4.2 0.7 324 28 304 255 0 0 0 0 17.8 0.2 18.8 17.4 04/26/2005 11:00:00 2.6 0.7 4.2 0.4 2.4 0.6 3.8 0.4 2.1 0.7 4.2 0.4 336 18 336 255 0 0 0 0 18.3 0.1 19.1 18 04/26/2005 11:10:00 2.3 0.8 4.2 0.4 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 333 29 332 255 0 0 0 0 18.5 0.1 18.8 18.2 04/26/2005 11:20:00 2.4 0.8 4.6 0.4 2.3 0.8 4.6 0.4 2.2 0.8 4.2 0.4 0 26 2 255 0 0 0 0 18.2 0 18.5 18 04/26/2005 11:30:00 2.2 0.5 3.4 0.7 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 9 15 3 255 0 0 0 0 18.2 0.1 18.8 18 04/26/2005 11:40:00 1.9 0.7 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 12 28 343 255 0 0 0 0 18.9 0.2 19.4 18.5 04/26/2005 11:50:00 2.2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 2 0.7 3.4 0.4 9 19 353 255 0 0 0 0 19 0.1 19.7 18.8 04/26/2005 12:00:00 2.1 0.7 3.8 0.4 1.9 0.8 3.8 0.4 1.8 0.8 3.4 0.4 348 24 337 255 0 0 0 0 19.5 0.2 20.3 19.1 04/26/2005 12:10:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 1.6 0.8 3.8 0.4 7 22 356 255 0 0 0 0 19.6 0.2 20 19.4 04/26/2005 12:20:00 2.6 0.8 4.6 0.7 2.4 0.8 4.6 0.4 2.3 0.9 4.6 0.4 355 36 298 255 0 0 0 0 19.6 0 20 19.4 04/26/2005 12:30:00 2.5 0.7 4.2 0.4 2.4 0.8 4.2 0.4 2.1 1 4.2 0.4 307 16 298 255 0 0 0 0 19.7 0 20.3 19.4 04/26/2005 12:40:00 2.8 1 4.9 0.4 2.6 1 4.9 0.4 2.4 1 4.9 0.4 305 30 318 255 0 0 0 0 19.9 0 20.5 19.4 04/26/2005 12:50:00 2 1 4.2 0.4 1.9 1.1 4.2 0.4 1.7 1 3.8 0.4 294 30 337 255 0 0 0 0 20.4 0.3 21.1 20 04/26/2005 13:00:00 2.8 0.8 4.6 0.7 2.7 1 4.6 0.4 2.4 1 4.6 0.4 296 22 331 255 0 0 0 0 20.7 0.2 21.1 20.5 04/26/2005 13:10:00 2.4 0.8 4.6 0.4 2.3 0.7 4.2 0.4 1.9 0.6 3.8 0.4 306 26 297 255 0 0 0 0 21 0.3 21.7 20.5 04/26/2005 13:20:00 2.9 0.8 4.6 0.7 2.7 0.9 4.2 0.7 2.5 1 4.6 0.4 318 23 282 255 0 0 0 0 21.4 0.1 22 21.1 04/26/2005 13:30:00 2.4 0.7 4.6 0.4 2.2 0.8 4.2 0.4 1.9 0.8 3.8 0.4 317 29 311 255 0 0 0 0 21 0.3 21.7 20.5 04/26/2005 13:40:00 2.2 0.8 4.2 0.7 2.1 0.8 3.8 0.4 2 0.7 3.8 0.4 314 27 302 255 0 0 0 0 21.6 0.2 22 21.1 04/26/2005 13:50:00 1.9 0.7 4.2 0.4 1.7 0.7 3.8 0.4 1.6 0.7 3.8 0.4 334 38 332 255 0 0 0 0 21.4 0.3 22.3 20.8 04/26/2005 14:00:00 2.8 0.7 5.3 0.4 2.7 0.7 4.2 0.4 2.3 0.8 4.6 0.7 307 30 335 255 0 0 0 0 22 0.1 22.6 21.7 04/26/2005 14:10:00 2 0.7 3.8 0.4 1.9 0.8 3.4 0.4 1.5 0.7 3.4 0.4 354 35 9 255 0 0 0 0 22.1 0.1 22.6 21.7 04/26/2005 14:20:00 1.8 1 4.6 0.4 1.7 0.9 4.2 0.4 1.6 0.9 3.8 0.4 347 41 14 255 0 0 0 0 22.4 0 22.9 22.3 04/26/2005 14:30:00 2.1 1 5.3 0.4 1.9 1 5.3 0.4 1.6 1 4.6 0.4 327 56 284 255 0 0 0 0 22.4 0 22.9 22.3 04/26/2005 14:40:00 2.6 0.8 4.6 0.7 2.5 0.8 4.6 0.4 2 1 4.2 0.4 8 26 20 255 0 0 0 0 22.8 0 23.2 22.6 04/26/2005 14:50:00 2.1 1 4.2 0.4 2 1 4.2 0.4 1.7 1 4.2 0.4 24 41 49 255 0 0 0 0 22.7 0.2 23.2 22.3 04/26/2005 15:00:00 2.8 1.2 5.3 0.4 2.6 1 4.9 0.4 2.4 1.1 4.9 0.4 331 43 337 255 0 0 0 0 22.5 0 22.9 22.3 04/26/2005 15:10:00 2.4 1.1 4.6 0.4 2.3 1.2 4.6 0.4 2.1 1 3.8 0.4 304 33 313 255 0 0 0 0 22.3 0.3 22.9 22 04/26/2005 15:20:00 3.3 0.9 5.3 0.7 3.3 0.9 5.3 1.1 2.9 1.1 5.7 0.4 288 22 323 255 0 0 0 0 22.5 0.2 22.9 22.3 04/26/2005 15:30:00 2.6 0.9 4.6 0.4 2.5 1 4.6 0.7 2.1 0.8 4.6 0.7 349 33 356 255 0 0 0 0 22.5 0 22.9 22.3 04/26/2005 15:40:00 2.7 1 4.6 0.4 2.6 1 4.6 0.4 2.3 1 4.9 0.4 284 39 309 255 0 0 0 0 22.4 0 22.6 22 04/26/2005 15:50:00 2.3 1.1 4.9 0.4 2.2 1 4.6 0.4 1.9 1 4.9 0.4 278 64 335 255 0 0 0 0 22.2 0 22.6 22 04/26/2005 16:00:00 2.3 1.1 4.9 0.4 2.1 1.1 4.6 0.4 2 1.1 4.9 0.4 290 33 311 255 0 0 0 0 22.1 0 22.3 21.7 04/26/2005 16:10:00 2.2 0.8 4.6 0.4 1.9 0.9 4.2 0.4 1.7 0.9 4.2 0.4 339 19 338 255 0 0 0 0 22 0 22.3 21.7 04/26/2005 16:20:00 2.6 0.9 4.6 0.4 2.4 0.9 4.6 0.4 2.1 0.9 4.6 0.4 296 22 281 255 0 0 0 0 22 0 22.3 21.7 04/26/2005 16:30:00 2.1 0.8 3.8 0.4 2 0.8 3.8 0.4 1.8 0.8 3.8 0.4 303 27 325 255 0 0 0 0 21.3 0.1 21.7 21.1 04/26/2005 16:40:00 1.4 1 3.4 0.4 1.3 1 3.4 0.4 1.1 0.9 3.4 0.4 352 29 343 255 0 0 0 0 21.5 0.1 22 21.1 04/26/2005 16:50:00 0.5 0.4 3.4 0.4 0.5 0.4 3 0.4 0.5 0.3 3.4 0.4 64 79 292 255 0 0 0 0 20.9 0.1 21.7 20.8 04/26/2005 17:00:00 2 0.9 4.2 0.4 1.7 0.7 3 0.4 1.8 0.9 4.2 0.4 311 29 329 255 0 0 0 0 21.1 0 21.7 20.8 04/26/2005 17:10:00 2 1.3 4.2 0.4 1.8 1.1 4.2 0.4 1.7 1.2 4.2 0.4 328 53 351 255 0 0 0 0 21 0 21.4 20.5 04/26/2005 17:20:00 1.2 0.7 3.4 0.4 1 0.6 3.4 0.4 0.7 0.5 2.6 0.4 310 36 317 255 0 0 0 0 20.3 0.1 20.8 20 04/26/2005 17:30:00 1.9 0.8 3.8 0.4 1.9 0.9 4.2 0.4 1.7 0.8 3.4 0.4 304 28 281 255 0 0 0 0 20 0 20.3 20 04/26/2005 17:40:00 2.5 0.8 4.6 0.4 2.3 0.9 4.6 0.4 1.8 0.8 3.8 0.4 282 22 253 255 0 0 0 0 20.3 0.1 20.8 20 04/26/2005 17:50:00 2.3 0.7 4.2 0.7 2.2 0.7 3.8 0.4 1.9 0.8 4.2 0.4 286 16 292 255 0 0 0 0 20.2 0 20.5 20 04/26/2005 18:00:00 1.4 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1 0.9 3.4 0.4 293 24 293 255 0 0 0 0 20 0 20.5 19.7 04/26/2005 18:10:00 1.9 0.7 3 0.4 1.8 0.6 3 0.4 1.4 0.7 3 0.4 280 18 276 255 0 0 0 0 19.8 0 20.3 19.7 04/26/2005 18:20:00 2 0.5 3.4 0.7 1.9 0.6 3 0.4 1.6 0.7 3 0.4 298 17 311 255 0 0 0 0 19.7 0 20.3 19.7 04/26/2005 18:30:00 1.7 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.2 0.7 3.8 0.4 278 18 306 255 0 0 0 0 19.5 0 20.3 19.4 04/26/2005 18:40:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 1.9 0.5 3 0.7 301 11 300 255 0 0 0 0 19.3 0 20 19.1 04/26/2005 18:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 310 10 310 255 0 0 0 0 19.2 0.1 20 18.8 04/26/2005 19:00:00 1.8 0.6 3 0.4 1.6 0.6 2.6 0.4 1.2 0.6 2.6 0.4 311 17 289 255 0 0 0 0 18.6 0.1 18.8 18.2 04/26/2005 19:10:00 2.3 0.6 3 0.4 2.2 0.6 3.4 0.4 1.8 0.7 3 0.4 294 12 283 255 0 0 0 0 18.2 0 18.2 18 04/26/2005 19:20:00 2.3 0.6 3.8 0.7 2.2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 302 12 291 255 0 0 0 0 17.8 0 18 17.7 04/26/2005 19:30:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 332 18 307 255 0 0 0 0 17.3 0.2 17.7 16.8 04/26/2005 19:40:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 339 13 343 255 0 0 0 0 16.3 0.2 16.8 16 04/26/2005 19:50:00 1.3 0.4 1.9 0.4 1.1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 354 5 351 255 0 0 0 0 15.9 0.2 16.3 15.5 04/26/2005 20:00:00 1.9 0.7 3.4 0.7 1.7 0.6 3 0.4 1.2 0.7 2.6 0.4 344 20 323 255 0 0 0 0 14.8 0.3 15.7 14.4 04/26/2005 20:10:00 1.7 0.7 3.4 0.4 1.5 0.7 3 0.4 1.1 0.7 3 0.4 304 11 315 255 0 0 0 0 14 0.1 14.9 13.5 04/26/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 294 0 255 255 0 0 0 0 13.3 0 13.5 13 04/26/2005 20:30:00 1.1 0.4 2.6 0.4 0.9 0.4 2.3 0.4 0.6 0.4 1.5 0.4 317 12 329 255 0 0 0 0 12.7 0.2 13.5 12.5 04/26/2005 20:40:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 333 15 302 255 0 0 0 0 12.3 0.1 12.7 11.9 04/26/2005 20:50:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 353 11 14 255 0 0 0 0 11.5 0.2 12.2 11.1 04/26/2005 21:00:00 1.2 0.3 2.3 0.4 0.9 0.4 2.3 0.4 0.7 0.3 1.5 0.4 343 7 339 255 0 0 0 0 11 0.1 11.7 10.9 04/26/2005 21:10:00 1.1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 357 3 353 255 0 0 0 0 10.7 0.1 11.1 10.6 04/26/2005 21:20:00 1.1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 31 6 16 255 0 0 0 0 10.2 0 10.6 10.1 04/26/2005 21:30:00 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.5 0.2 1.5 0.4 28 12 40 255 0 0 0 0 10 0 10.6 9.8 04/26/2005 21:40:00 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.4 0.2 1.5 0.4 30 19 59 255 0 0 0 0 9.6 0.1 10.1 9.6 04/26/2005 21:50:00 1.6 0.4 2.6 0.7 1.5 0.4 2.3 0.7 1.1 0.4 1.9 0.4 71 8 63 255 0 0 0 0 9.4 0 9.8 9 04/26/2005 22:00:00 1.4 0.4 2.3 0.4 1.2 0.4 1.9 0.4 0.9 0.4 1.9 0.4 67 7 69 255 0 0 0 0 8.9 0 9.6 8.8 04/26/2005 22:10:00 1.7 0.6 3 0.4 1.5 0.6 2.6 0.4 1.2 0.4 2.3 0.4 78 5 83 255 0 0 0 0 8.7 0.2 9.3 8.5 04/26/2005 22:20:00 2.4 0.3 3 1.9 2.3 0.3 3 1.1 1.5 0.4 2.6 0.7 81 7 83 255 0 0 0 0 8.5 0 9 8.5 04/26/2005 22:30:00 2.5 0.3 3.4 1.1 2.3 0.4 3.4 1.5 1.3 0.5 2.3 0.4 102 5 93 255 0 0 0 0 8.3 0 9 8.3 04/26/2005 22:40:00 2.2 0.3 3 1.1 2.1 0.3 2.6 1.1 1.1 0.4 1.9 0.4 107 5 98 255 0 0 0 0 8 0.1 8.5 7.8 04/26/2005 22:50:00 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 0.8 0.4 1.9 0.4 119 6 121 255 0 0 0 0 7.9 0 8.3 7.8 04/26/2005 23:00:00 2.1 0.4 3.4 1.1 2 0.4 3 1.1 1.4 0.4 2.3 0.7 128 9 130 255 0 0 0 0 7.8 0 7.8 7.8 04/26/2005 23:10:00 2.4 0.5 3.8 1.1 2.3 0.6 3.8 1.1 1.8 0.5 3 0.4 129 10 119 255 0 0 0 0 7.6 0 8 7.3 04/26/2005 23:20:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 0.8 0.5 2.3 0.4 120 12 114 255 0 0 0 0 7.2 0 7.5 7 04/26/2005 23:30:00 2.2 0.6 4.2 1.1 2.1 0.6 4.2 0.7 1.3 0.5 3 0.4 120 12 113 255 0 0 0 0 6.8 0 7.5 6.5 04/26/2005 23:40:00 1.9 0.5 3.4 0.7 1.7 0.6 3.4 0.4 1.1 0.5 2.6 0.4 119 11 110 255 0 0 0 0 6.5 0 6.7 6.5 04/26/2005 23:50:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.1 0.5 2.6 0.4 119 13 121 255 0 0 0 0 6.4 0.1 6.7 6.2 04/27/2005 00:00:00 1.8 0.7 3.4 0.4 1.6 0.7 3 0.4 0.9 0.6 3 0.4 109 17 102 255 0 0 0 0 6.1 0 6.2 6 04/27/2005 00:10:00 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.4 1.9 0.4 82 11 76 255 0 0 0 0 6.3 0.1 6.7 6 04/27/2005 00:20:00 2 0.4 3.4 0.4 1.8 0.5 3.4 0.4 1 0.4 1.9 0.4 76 7 74 255 0 0 0 0 6.1 0 6.2 5.7 04/27/2005 00:30:00 2.4 0.6 3.8 0.7 2.2 0.6 3.4 0.7 1.3 0.7 3 0.4 101 11 103 255 0 0 0 0 5.9 0 6.2 5.7 04/27/2005 00:40:00 3.4 0.4 4.2 2.3 3.3 0.3 4.2 2.3 2.1 0.5 3.4 0.7 103 7 101 255 0 0 0 0 6.2 0 6.2 6 04/27/2005 00:50:00 2.9 0.4 4.2 1.9 2.8 0.4 3.8 1.5 1.8 0.5 3 0.4 105 9 100 255 0 0 0 0 6.1 0 6.2 6 04/27/2005 01:00:00 2.9 0.4 3.8 1.9 2.7 0.4 3.4 1.5 1.7 0.5 3 0.4 105 7 105 255 0 0 0 0 5.9 0.1 6.2 5.7 04/27/2005 01:10:00 3.2 0.4 3.8 2.3 3 0.4 3.8 1.9 1.9 0.5 3 0.7 108 8 106 255 0 0 0 0 6.2 0 6.7 6 04/27/2005 01:20:00 3 0.4 3.8 1.9 2.9 0.4 3.8 1.5 1.8 0.6 3 0.4 110 9 101 255 0 0 0 0 6.1 0 6.2 5.7 04/27/2005 01:30:00 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.5 2.1 0.5 3 0.7 108 9 96 255 0 0 0 0 5.9 0 6 5.7 04/27/2005 01:40:00 2.6 0.8 4.2 0.4 2.4 0.8 3.8 0.4 1.7 0.7 3 0.4 113 13 106 255 0 0 0 0 5.4 0.2 5.7 5 04/27/2005 01:50:00 1.9 0.6 3.4 0.4 1.7 0.6 3 0.4 1.1 0.4 2.3 0.4 126 9 113 255 0 0 0 0 5.1 0 5.5 5 04/27/2005 02:00:00 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 1.7 0.6 3.4 0.4 123 13 99 255 0 0 0 0 5.1 0 5.5 5 04/27/2005 02:10:00 2 0.7 4.2 0.4 1.7 0.7 3.8 0.4 0.9 0.6 2.6 0.4 115 20 92 255 0 0 0 0 5 0 5 4.8 04/27/2005 02:20:00 3.3 0.5 4.9 1.9 3.2 0.5 4.9 1.9 2.3 0.6 3.8 0.7 106 9 107 255 0 0 0 0 4.9 0 5.2 4.8 04/27/2005 02:30:00 3.4 0.5 4.9 1.9 3.4 0.5 4.6 1.5 2.6 0.5 3.8 1.1 108 8 101 255 0 0 0 0 5.1 0.1 5.5 4.8 04/27/2005 02:40:00 3.2 0.4 4.2 1.5 3.1 0.4 4.2 1.9 2.1 0.5 3.4 0.4 109 8 94 255 0 0 0 0 4.9 0 5 4.8 04/27/2005 02:50:00 3 0.4 4.2 1.9 2.9 0.4 3.8 1.5 2 0.5 3 0.7 104 8 100 255 0 0 0 0 4.7 0.2 5 4.3 04/27/2005 03:00:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.3 0.5 2.6 0.4 111 8 99 255 0 0 0 0 4.3 0 4.5 4 04/27/2005 03:10:00 2.8 0.4 3.8 1.9 2.7 0.4 3.4 1.5 1.8 0.4 3 0.7 111 7 115 255 0 0 0 0 4.3 0.1 4.5 4 04/27/2005 03:20:00 2.9 0.5 4.2 1.1 2.7 0.6 3.8 1.5 1.7 0.6 3.4 0.4 109 11 121 255 0 0 0 0 4.3 0.2 4.5 4 04/27/2005 03:30:00 3.6 0.5 4.9 1.9 3.5 0.6 4.6 1.9 2.3 0.6 3.8 0.4 105 9 104 255 0 0 0 0 4.6 0 4.8 4.5 04/27/2005 03:40:00 3.3 0.5 4.6 2.3 3.2 0.5 4.2 1.9 2.3 0.6 4.2 0.7 105 9 89 255 0 0 0 0 4.8 0 5 4.5 04/27/2005 03:50:00 2.5 0.7 4.2 1.1 2.4 0.7 4.2 0.7 1.6 0.6 3 0.4 115 12 109 255 0 0 0 0 4.5 0 4.8 4.5 04/27/2005 04:00:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.7 0.5 3 0.4 115 11 104 255 0 0 0 0 4.6 0 4.8 4.3 04/27/2005 04:10:00 1.9 0.6 3.8 0.4 1.7 0.6 3.8 0.4 0.9 0.5 2.6 0.4 118 11 102 255 0 0 0 0 4.3 0.2 4.8 4 04/27/2005 04:20:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 0.6 0.4 2.6 0.4 120 9 97 255 0 0 0 0 4 0 4.3 3.8 04/27/2005 04:30:00 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 124 7 119 255 0 0 0 0 3.7 0.1 4 3.5 04/27/2005 04:40:00 2.2 0.4 3.4 0.7 2.1 0.5 3 0.4 1.1 0.5 2.3 0.4 110 8 118 255 0 0 0 0 3.5 0 3.5 3.3 04/27/2005 04:50:00 2.1 0.7 3.8 0.4 2 0.7 3.4 0.4 1.2 0.6 2.6 0.4 111 12 108 255 0 0 0 0 3.3 0 3.5 3.3 04/27/2005 05:00:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 103 8 92 255 0 0 0 0 3.2 0 3.5 3 04/27/2005 05:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 126 13 133 255 0 0 0 0 3.2 0 3.5 3 04/27/2005 05:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 134 8 133 255 0 0 0 0 3.1 0 3.5 2.8 04/27/2005 05:30:00 1.9 0.5 2.6 0.4 1.7 0.5 2.6 0.7 0.7 0.4 1.5 0.4 116 7 106 255 0 0 0 0 3.1 0 3.3 2.8 04/27/2005 05:40:00 1.8 0.5 3 0.4 1.7 0.5 2.6 0.4 1.1 0.5 2.3 0.4 123 9 111 255 0 0 0 0 3.4 0 3.8 3.3 04/27/2005 05:50:00 2 0.5 3 0.7 2 0.6 3 0.7 1.6 0.4 2.6 0.4 125 10 116 255 0 0 0 0 3.8 0.2 4.3 3.5 04/27/2005 06:00:00 2.5 0.5 3.4 1.5 2.3 0.5 3.4 1.1 1.4 0.5 2.6 0.4 114 10 99 255 0 0 0 0 4.6 0.3 5 4.3 04/27/2005 06:10:00 2.1 0.5 3 0.7 2 0.5 3.4 0.4 1.5 0.4 2.6 0.4 108 7 108 255 0 0 0 0 5.1 0 5.5 5 04/27/2005 06:20:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.2 1.5 0.4 124 5 90 255 0 0 0 0 5.7 0.2 6.2 5.5 04/27/2005 06:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 2.3 0.4 114 20 125 255 0 0 0 0 6.9 0.4 7.8 6.2 04/27/2005 06:40:00 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.4 0.2 1.5 0.4 92 18 134 255 0 0 0 0 8.1 0.3 8.8 7.5 04/27/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 13 255 255 0 0 0 0 9.2 0.3 9.6 8.8 04/27/2005 07:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 346 23 312 255 0 0 0 0 9.9 0.1 10.3 9.6 04/27/2005 07:10:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.5 1.9 0.4 302 2 301 255 0 0 0 0 9.8 0.1 10.6 9.6 04/27/2005 07:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 0 0 0 0 10.7 0.3 11.4 10.1 04/27/2005 07:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 308 11 302 255 0 0 0 0 11.4 0.1 11.7 11.1 04/27/2005 07:40:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 356 15 4 255 0 0 0 0 11.7 0.1 12.2 11.4 04/27/2005 07:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 24 41 358 255 0 0 0 0 12.1 0 12.5 11.9 04/27/2005 08:00:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.9 0.4 1.9 0.4 25 28 15 255 0 0 0 0 12.5 0 13 12.5 04/27/2005 08:10:00 1.2 0.5 2.3 0.4 1.2 0.4 2.3 0.4 1.1 0.5 1.9 0.4 14 12 8 255 0 0 0 0 12.8 0 13.3 12.5 04/27/2005 08:20:00 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 341 13 355 255 0 0 0 0 13.3 0 13.5 12.7 04/27/2005 08:30:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.5 2.6 0.4 349 19 325 255 0 0 0 0 13.5 0 13.8 13.3 04/27/2005 08:40:00 1.2 0.5 2.6 0.4 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 11 15 1 255 0 0 0 0 13.7 0 14.4 13.3 04/27/2005 08:50:00 1.1 0.4 2.3 0.4 1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 336 26 2 255 0 0 0 0 14.1 0.1 14.6 13.8 04/27/2005 09:00:00 0.9 0.5 2.3 0.4 0.8 0.4 2.3 0.4 0.8 0.4 1.9 0.4 355 26 10 255 0 0 0 0 14.6 0 15.2 14.4 04/27/2005 09:10:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.6 2.3 0.4 12 20 16 255 0 0 0 0 14.9 0 15.2 14.6 04/27/2005 09:20:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 1.2 0.7 3 0.4 10 18 354 255 0 0 0 0 15.2 0.1 15.5 14.9 04/27/2005 09:30:00 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 341 33 299 255 0 0 0 0 15.2 0 15.5 15.2 04/27/2005 09:40:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 341 22 328 255 0 0 0 0 15.7 0 16 15.5 04/27/2005 09:50:00 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 356 33 20 255 0 0 0 0 15.7 0.2 16.3 15.2 04/27/2005 10:00:00 1.6 0.6 3 0.4 1.4 0.7 3.4 0.4 1.2 0.8 3 0.4 319 24 298 255 0 0 0 0 16.2 0.1 16.6 16 04/27/2005 10:10:00 1.8 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.7 0.7 3.4 0.4 300 11 315 255 0 0 0 0 16.1 0 16.8 16 04/27/2005 10:20:00 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1.3 0.8 3 0.4 311 29 318 255 0 0 0 0 16.4 0.1 16.8 16.3 04/27/2005 10:30:00 1.4 0.8 3.4 0.4 1.4 0.8 3 0.4 1.4 0.8 3.4 0.4 287 47 295 255 0 0 0 0 16.8 0.1 17.4 16.6 04/27/2005 10:40:00 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 316 26 313 255 0 0 0 0 16.7 0.4 17.7 16.3 04/27/2005 10:50:00 1.9 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.9 1.1 4.6 0.4 302 20 302 255 0 0 0 0 17.3 0 17.7 17.1 04/27/2005 11:00:00 1.4 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.6 3 0.4 295 29 313 255 0 0 0 0 17.5 0.2 18.2 17.1 04/27/2005 11:10:00 2.1 0.6 3.8 0.7 1.8 0.6 3.4 0.4 1.4 0.7 3 0.4 332 30 315 255 0 0 0 0 18.4 0.3 19.1 17.7 04/27/2005 11:20:00 1.9 0.7 3 0.4 1.9 0.7 3.8 0.4 1.6 0.6 3.4 0.4 292 30 327 255 0 0 0 0 18.5 0.2 19.4 18 04/27/2005 11:30:00 2.4 0.6 4.6 1.1 2.2 0.7 4.2 0.4 2.2 0.7 4.2 0.4 335 21 308 255 0 0 0 0 18.7 0 19.1 18.2 04/27/2005 11:40:00 2.3 0.8 4.2 0.4 2.1 0.9 4.2 0.4 2 1 3.8 0.4 326 36 311 255 0 0 0 0 18.7 0 19.1 18.5 04/27/2005 11:50:00 1.8 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.3 0.7 3 0.4 282 41 287 255 0 0 0 0 19.1 0.4 20 18.5 04/27/2005 12:00:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 0.9 0.4 2.3 0.4 242 82 252 255 0 0 0 0 19.8 0 20.3 19.4 04/27/2005 12:10:00 1.8 1 4.6 0.4 1.7 1.1 4.9 0.4 1.4 1 3.4 0.4 260 66 331 255 0 0 0 0 20.3 0.3 20.8 19.7 04/27/2005 12:20:00 1.9 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.8 4.6 0.4 272 41 327 255 0 0 0 0 19.7 0 20.3 19.4 04/27/2005 12:30:00 2.4 1.5 6.8 0.4 2.4 1.5 6.5 0.4 2.1 1.4 6.8 0.4 259 21 266 255 0 0 0 0 19.9 0 20.3 19.7 04/27/2005 12:40:00 2.4 0.8 4.2 0.4 2.3 0.9 4.2 0.4 2 0.7 3.8 0.4 274 30 254 255 0 0 0 0 20.3 0 20.5 20 04/27/2005 12:50:00 2.8 0.8 4.9 0.4 2.6 0.9 4.9 0.4 2.2 1 4.2 0.4 293 32 328 255 0 0 0 0 20.1 0.2 20.5 19.7 04/27/2005 13:00:00 2 0.9 3.8 0.4 1.9 1 3.8 0.4 1.9 1 3.8 0.4 265 30 259 255 0 0 0 0 20.2 0 20.5 20 04/27/2005 13:10:00 2.8 0.8 5.3 0.7 2.7 0.9 5.3 0.4 2.4 0.9 4.6 0.4 302 26 282 255 0 0 0 0 20.4 0 20.8 20.3 04/27/2005 13:20:00 2.6 1 5.3 0.4 2.5 1 4.9 0.4 2.3 1.2 5.3 0.4 285 64 295 255 0 0 0 0 20.7 0.1 21.1 20.5 04/27/2005 13:30:00 2.5 1 4.9 0.4 2.5 1 5.3 0.4 2.3 1.1 4.9 0.4 274 30 303 255 0 0 0 0 21.2 0 21.4 21.1 04/27/2005 13:40:00 2.5 0.9 4.6 0.4 2.4 1 4.6 0.4 2.1 1 4.2 0.4 289 43 297 255 0 0 0 0 21.5 0.2 22.3 21.1 04/27/2005 13:50:00 2.1 1 4.2 0.4 2 1 4.6 0.4 1.8 1 4.2 0.4 274 53 295 255 0 0 0 0 21.7 0.2 22.3 21.4 04/27/2005 14:00:00 2.5 0.9 4.6 0.4 2.5 1 4.2 0.4 2 0.9 4.2 0.4 273 36 251 255 0 0 0 0 21.4 0.2 22.3 21.1 04/27/2005 14:10:00 1.9 0.9 4.9 0.4 1.9 0.9 4.6 0.4 1.5 0.9 4.2 0.4 297 69 318 255 0 0 0 0 22 0.2 22.9 21.4 04/27/2005 14:20:00 2.4 0.9 4.6 0.4 2.4 0.9 4.6 0.4 2 0.9 4.2 0.4 257 28 276 255 0 0 0 0 22 0.3 22.9 21.7 04/27/2005 14:30:00 2.1 0.8 3.8 0.4 2.1 0.7 3.8 0.4 2 0.8 3.8 0.4 274 22 298 255 0 0 0 0 22 0.1 22.6 21.7 04/27/2005 14:40:00 2.3 1 4.6 0.4 2.3 1 4.2 0.4 2 1 4.2 0.4 283 35 259 255 0 0 0 0 22.4 0.1 22.9 22 04/27/2005 14:50:00 2.2 1 4.6 0.4 2.1 0.9 4.6 0.4 1.8 1 4.6 0.4 276 33 274 255 0 0 0 0 22.2 0 22.6 22 04/27/2005 15:00:00 2.1 0.8 4.2 0.4 1.9 0.8 3.8 0.4 1.6 1 4.2 0.4 304 35 274 255 0 0 0 0 22.4 0.1 22.9 22.3 04/27/2005 15:10:00 1.9 0.9 3.8 0.4 1.9 0.9 4.2 0.4 1.7 1 4.6 0.4 259 51 299 255 0 0 0 0 22.3 0.1 23.2 22 04/27/2005 15:20:00 1.9 0.8 4.2 0.4 1.8 0.8 4.2 0.4 1.6 0.8 3.8 0.4 233 27 236 255 0 0 0 0 22.2 0 22.6 22 04/27/2005 15:30:00 2.1 1 4.2 0.4 2.1 1 4.2 0.4 1.9 0.8 3.8 0.4 269 47 309 255 0 0 0 0 22.6 0 22.9 22.3 04/27/2005 15:40:00 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1.1 0.8 3 0.4 316 35 313 255 0 0 0 0 22.8 0 23.2 22.9 04/27/2005 15:50:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.4 0.8 3.8 0.4 328 41 305 255 0 0 0 0 22.7 0 22.9 22.6 04/27/2005 16:00:00 2.3 1 4.6 0.4 2.4 0.9 4.6 0.4 1.9 1 4.6 0.4 285 22 270 255 0 0 0 0 22.5 0 22.9 22.3 04/27/2005 16:10:00 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1.2 0.8 3.8 0.4 325 28 288 255 0 0 0 0 22.7 0 22.9 22.6 04/27/2005 16:20:00 1.7 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.3 0.6 2.6 0.4 331 20 332 255 0 0 0 0 22.6 0.1 22.9 22.3 04/27/2005 16:30:00 1.7 0.7 3 0.4 1.7 0.7 3.8 0.4 1.5 0.7 3.4 0.4 21 41 350 255 0 0 0 0 21.9 0.2 22.3 21.7 04/27/2005 16:40:00 2.1 0.9 4.6 0.4 2 0.8 3.8 0.4 1.8 1 4.2 0.4 2 35 338 255 0 0 0 0 21.9 0 22.3 21.7 04/27/2005 16:50:00 1.8 0.8 3.4 0.4 1.8 0.8 3.8 0.4 1.5 0.7 3.4 0.4 313 32 300 255 0 0 0 0 22.1 0 22.6 22 04/27/2005 17:00:00 1.4 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.7 3 0.4 339 45 292 255 0 0 0 0 22 0 22.6 22 04/27/2005 17:10:00 1.6 0.6 3.4 0.4 1.6 0.6 3.8 0.4 1.3 0.6 3 0.4 349 28 28 255 0 0 0 0 21.8 0 22 21.7 04/27/2005 17:20:00 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 1.4 0.6 3 0.4 347 20 355 255 0 0 0 0 21.9 0 22.6 21.7 04/27/2005 17:30:00 1.1 0.7 2.3 0.4 1 0.7 2.3 0.4 0.9 0.5 2.3 0.4 25 35 73 255 0 0 0 0 21.7 0 22.3 21.4 04/27/2005 17:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.9 0.4 0.5 0.4 1.9 0.4 39 53 318 255 0 0 0 0 21.6 0 21.7 21.4 04/27/2005 17:50:00 1.5 0.9 3 0.4 1.2 0.7 2.6 0.4 1.3 0.8 3 0.4 9 39 344 255 0 0 0 0 21.4 0 21.7 21.1 04/27/2005 18:00:00 2.1 1 4.2 0.4 2 1 4.2 0.4 1.6 0.8 3.4 0.4 356 15 1 255 0 0 0 0 21.3 0 21.7 21.1 04/27/2005 18:10:00 3.6 0.5 4.9 1.9 3.6 0.5 4.6 2.3 2.9 0.6 4.6 0.7 12 12 23 255 0 0 0 0 21.1 0.1 21.7 20.8 04/27/2005 18:20:00 3 0.8 4.9 1.5 3 0.8 4.9 1.5 2.6 0.8 4.2 0.4 25 12 50 255 0 0 0 0 20.7 0.1 21.4 20.5 04/27/2005 18:30:00 2.2 1 3.8 0.4 2.2 1 4.2 0.4 1.7 1.1 3.8 0.4 15 15 40 255 0 0 0 0 20.3 0.2 21.1 20 04/27/2005 18:40:00 3.2 0.7 4.9 1.1 3.1 0.8 4.9 1.1 2.7 1 4.6 0.4 28 15 30 255 0 0 0 0 20 0 20.5 20 04/27/2005 18:50:00 2.2 1 4.9 0.4 2.1 1.1 4.6 0.4 1.6 1 4.6 0.4 0 47 49 255 0 0 0 0 19.6 0.1 20.3 19.1 04/27/2005 19:00:00 1.9 0.8 3.4 0.4 1.8 0.8 3.4 0.4 1.5 0.8 3 0.4 13 47 38 255 0 0 0 0 19 0 19.7 18.8 04/27/2005 19:10:00 2.2 1 4.2 0.4 2.1 1 4.2 0.4 1.7 1 4.2 0.4 27 24 62 255 0 0 0 0 18.5 0.1 19.4 18.2 04/27/2005 19:20:00 3 0.7 4.6 1.1 2.9 0.8 4.6 0.4 2.5 0.7 4.2 0.4 40 12 45 255 0 0 0 0 18.4 0 18.5 18.2 04/27/2005 19:30:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2.4 0.7 3.8 0.4 42 13 27 255 0 0 0 0 18.2 0 18.2 18 04/27/2005 19:40:00 3.2 0.6 4.9 1.1 3.1 0.7 5.3 0.7 2.6 0.9 4.2 0.4 53 14 36 255 0 0 0 0 17.8 0 18 17.4 04/27/2005 19:50:00 3.4 0.6 4.9 1.5 3.3 0.6 4.9 1.5 2.8 0.7 4.6 1.1 55 12 51 255 0 0 0 0 17.3 0 17.4 16.8 04/27/2005 20:00:00 3.3 0.6 4.9 1.5 3.4 0.6 4.6 1.9 2.8 0.7 4.6 1.5 54 12 68 255 0 0 0 0 16.7 0 17.1 16.6 04/27/2005 20:10:00 2.6 0.5 4.2 1.5 2.5 0.5 4.2 1.5 2.1 0.5 3.4 1.1 72 15 60 255 0 0 0 0 16.1 0.2 16.8 15.7 04/27/2005 20:20:00 2.7 0.6 4.6 1.1 2.7 0.6 4.6 1.1 2.3 0.6 3.8 1.1 68 17 24 255 0 0 0 0 15.4 0.1 15.7 15.2 04/27/2005 20:30:00 2.5 0.7 4.6 0.7 2.4 0.7 4.6 1.1 1.8 0.6 3.4 0.4 80 18 88 255 0 0 0 0 14.8 0.2 15.5 14.6 04/27/2005 20:40:00 3.2 0.6 5.7 1.9 3.2 0.6 5.3 1.9 2.6 0.7 4.2 1.1 71 12 66 255 0 0 0 0 14.5 0 14.9 14.4 04/27/2005 20:50:00 3.3 0.8 4.9 1.5 3.3 0.8 4.9 1.5 2.6 0.7 4.9 1.1 73 14 67 255 0 0 0 0 14.4 0 14.6 14.1 04/27/2005 21:00:00 3.1 0.7 5.3 1.5 3 0.8 5.3 1.1 2.4 0.7 4.6 0.7 72 13 78 255 0 0 0 0 13.8 0.2 14.6 13.3 04/27/2005 21:10:00 2.7 0.9 5.3 0.4 2.6 0.9 5.3 0.4 2 1 4.6 0.4 68 18 80 255 0 0 0 0 13.7 0.2 14.1 13.3 04/27/2005 21:20:00 2.2 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.4 0.7 3 0.4 86 17 64 255 0 0 0 0 12.9 0.3 13.5 12.5 04/27/2005 21:30:00 2.3 0.7 4.2 1.1 2.3 0.7 4.2 0.7 1.6 0.7 3.4 0.4 69 22 96 255 0 0 0 0 12.3 0.3 13 11.7 04/27/2005 21:40:00 2.6 0.7 4.6 1.1 2.6 0.7 4.2 1.1 1.8 0.6 4.2 0.4 74 16 74 255 0 0 0 0 11.5 0.1 11.9 11.1 04/27/2005 21:50:00 2.6 0.7 4.6 1.1 2.6 0.7 4.6 1.1 2 0.8 3.8 0.4 69 15 43 255 0 0 0 0 11.2 0 11.7 11.1 04/27/2005 22:00:00 1.7 0.9 4.2 0.4 1.5 1 4.2 0.4 1 0.8 3.4 0.4 61 20 49 255 0 0 0 0 10.9 0.3 11.4 10.3 04/27/2005 22:10:00 1.6 0.5 3 0.7 1.4 0.5 2.6 0.4 0.9 0.5 1.9 0.4 90 17 58 255 0 0 0 0 10.1 0 10.6 9.8 04/27/2005 22:20:00 2.5 0.9 4.2 0.4 2.4 1 4.6 0.4 1.9 0.8 3 0.4 70 14 60 255 0 0 0 0 9.8 0 10.3 9.6 04/27/2005 22:30:00 3.3 0.6 4.9 1.9 3.3 0.6 4.9 1.9 2.4 0.6 4.6 1.1 58 16 71 255 0 0 0 0 10.5 0.1 11.1 9.8 04/27/2005 22:40:00 2.5 0.6 4.2 1.5 2.5 0.6 4.2 1.1 1.9 0.6 3.4 0.4 60 18 70 255 0 0 0 0 10.8 0.2 11.1 10.6 04/27/2005 22:50:00 3 0.7 4.9 1.5 2.9 0.8 4.9 1.5 2.2 0.7 4.6 1.1 53 21 30 255 0 0 0 0 10.5 0 11.1 10.3 04/27/2005 23:00:00 2.8 0.8 4.6 0.7 2.7 0.8 4.9 0.7 1.7 0.8 3.4 0.4 38 29 358 255 0 0 0 0 9.7 0.3 10.3 9 04/27/2005 23:10:00 2.4 0.8 4.6 0.7 2.3 0.9 4.6 0.7 1.8 0.8 4.2 0.4 52 20 46 255 0 0 0 0 9.2 0 9.6 9 04/27/2005 23:20:00 1.6 0.7 3.4 0.4 1.5 0.6 3.4 0.4 1.1 0.8 3.4 0.4 43 53 339 255 0 0 0 0 9 0 9.3 8.8 04/27/2005 23:30:00 0.9 0.7 3.8 0.4 0.8 0.7 3.4 0.4 0.6 0.5 3 0.4 37 38 84 255 0 0 0 0 8.7 0 8.8 8.5 04/27/2005 23:40:00 2.5 0.9 4.6 0.4 2.5 0.9 4.6 0.4 1.9 0.9 4.2 0.4 57 22 56 255 0 0 0 0 8.7 0.2 9.3 8.5 04/27/2005 23:50:00 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 51 24 98 255 0 0 0 0 8.5 0.1 9 8.3 04/28/2005 00:00:00 2.5 0.7 4.9 1.1 2.4 0.8 4.9 0.7 1.7 1 4.2 0.4 61 17 62 255 0 0 0 0 8.1 0.2 9 7.8 04/28/2005 00:10:00 1.6 1 3.8 0.4 1.5 1 3.8 0.4 1 0.8 3.4 0.4 47 13 38 255 0 0 0 0 8.2 0.1 9 8 04/28/2005 00:20:00 1.7 0.9 3.8 0.4 1.6 1 3.4 0.4 1.1 0.7 3 0.4 73 17 68 255 0 0 0 0 7.8 0.1 8.5 7.5 04/28/2005 00:30:00 1.4 0.7 3 0.4 1.2 0.7 3 0.4 0.9 0.5 2.3 0.4 77 24 85 255 0 0 0 0 7.2 0.2 7.8 7 04/28/2005 00:40:00 1.8 0.9 3.4 0.4 1.6 0.9 3.4 0.4 1.1 0.7 2.6 0.4 77 17 48 255 0 0 0 0 7 0 7.3 7 04/28/2005 00:50:00 2.2 0.5 3.8 1.1 2.1 0.5 3.8 0.7 1.3 0.6 2.6 0.4 67 27 49 255 0 0 0 0 6.6 0.1 7 6.2 04/28/2005 01:00:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 0.6 0.4 2.3 0.4 55 22 84 255 0 0 0 0 6.4 0.1 6.7 6.2 04/28/2005 01:10:00 1.3 0.6 2.6 0.4 1.2 0.7 2.6 0.4 0.9 0.5 1.9 0.4 40 18 26 255 0 0 0 0 6.5 0.1 7 6.2 04/28/2005 01:20:00 1.2 0.9 3 0.4 1.1 0.8 3 0.4 0.8 0.6 2.3 0.4 72 39 31 255 0 0 0 0 6.2 0 6.7 6 04/28/2005 01:30:00 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.6 0.4 1.9 0.4 41 22 40 255 0 0 0 0 6 0 6.5 5.7 04/28/2005 01:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 46 24 10 255 0 0 0 0 5.6 0.2 6.2 5.2 04/28/2005 01:50:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 61 19 53 255 0 0 0 0 5.4 0 6 5.2 04/28/2005 02:00:00 1.3 0.6 2.6 0.4 1.2 0.6 2.3 0.4 0.9 0.5 1.9 0.4 72 15 55 255 0 0 0 0 5.2 0.1 5.7 5 04/28/2005 02:10:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 79 12 84 255 0 0 0 0 4.9 0.1 5.7 4.8 04/28/2005 02:20:00 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1 0.5 1.9 0.4 70 12 74 255 0 0 0 0 4.7 0 4.8 4.5 04/28/2005 02:30:00 1.8 0.5 2.6 0.4 1.7 0.6 2.6 0.4 0.9 0.5 1.9 0.4 44 11 42 255 0 0 0 0 4.4 0 5 4.3 04/28/2005 02:40:00 1.6 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.1 0.6 3 0.4 25 35 28 255 0 0 0 0 4.3 0 4.5 4.3 04/28/2005 02:50:00 0.8 0.6 2.3 0.4 0.6 0.5 2.6 0.4 0.5 0.4 2.3 0.4 19 56 26 255 0 0 0 0 4.5 0 4.5 4.3 04/28/2005 03:00:00 1.2 0.8 3 0.4 1 0.7 3 0.4 0.6 0.4 1.9 0.4 354 19 355 255 0 0 0 0 4.3 0 4.5 4.3 04/28/2005 03:10:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.9 0.4 344 43 269 255 0 0 0 0 4 0 4.3 4 04/28/2005 03:20:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 316 38 310 255 0 0 0 0 3.8 0 4 3.5 04/28/2005 03:30:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 305 29 293 255 0 0 0 0 3.8 0 4 3.5 04/28/2005 03:40:00 1.6 0.6 3 0.4 1.5 0.6 2.6 0.4 0.9 0.6 2.6 0.4 291 28 258 255 0 0 0 0 3.8 0.2 4.3 3.5 04/28/2005 03:50:00 2.1 1 4.2 0.4 1.9 1 4.2 0.4 1.1 0.8 2.6 0.4 313 49 243 255 0 0 0 0 3.4 0 3.5 3.3 04/28/2005 04:00:00 1.3 1 3.4 0.4 1.2 1 3.4 0.4 1.1 0.8 2.6 0.4 252 64 264 255 0 0 0 0 3.5 0.2 3.8 3.3 04/28/2005 04:10:00 1.5 1 3.8 0.4 1.4 1 3.8 0.4 1 0.8 3 0.4 217 69 237 255 0 0 0 0 3.6 0 3.8 3.5 04/28/2005 04:20:00 1.8 1.3 4.6 0.4 1.7 1.3 4.6 0.4 1.2 1 3.8 0.4 279 23 263 255 0 0 0 0 3.6 0.1 4 3.5 04/28/2005 04:30:00 1.7 1 4.2 0.4 1.5 1.1 3.8 0.4 1.2 0.8 3.4 0.4 297 39 291 255 0 0 0 0 3.4 0 3.8 3.3 04/28/2005 04:40:00 2.3 1.1 4.2 0.4 2.3 1.1 4.6 0.4 1.7 1 4.2 0.4 302 32 292 255 0 0 0 0 3.6 0 3.8 3.3 04/28/2005 04:50:00 2.4 1 4.6 0.4 2.4 1 4.6 0.4 1.6 0.8 3.8 0.4 276 21 265 255 0 0 0 0 3.7 0 3.8 3.5 04/28/2005 05:00:00 1.8 1.5 4.9 0.4 1.7 1.5 4.9 0.4 1.3 1.1 3.8 0.4 314 69 271 255 0 0 0 0 4.1 0.3 4.5 3.8 04/28/2005 05:10:00 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 0.7 0.5 2.3 0.4 277 16 288 255 0 0 0 0 4.2 0.1 4.5 4 04/28/2005 05:20:00 1.6 0.8 3.8 0.4 1.5 0.9 3.4 0.4 1.2 0.6 2.6 0.4 271 39 270 255 0 0 0 0 4.4 0.4 5 3.8 04/28/2005 05:30:00 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.7 0.4 1.9 0.4 300 32 276 255 0 0 0 0 4.6 0 4.8 4.5 04/28/2005 05:40:00 1.1 0.7 3 0.4 1 0.7 3 0.4 0.6 0.4 1.9 0.4 287 29 268 255 0 0 0 0 4.6 0 4.8 4.5 04/28/2005 05:50:00 1.1 0.9 3.4 0.4 1 0.9 3 0.4 0.9 0.7 2.6 0.4 23 76 259 255 0 0 0 0 5.1 0.3 5.7 4.5 04/28/2005 06:00:00 0.5 0.3 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 0.7 0.4 257 0 262 255 0 0 0 0 5.4 0 5.7 5.2 04/28/2005 06:10:00 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 263 7 256 255 0 0 0 0 5.7 0 6 5.7 04/28/2005 06:20:00 1.5 0.8 3.4 0.4 1.5 0.8 3 0.4 0.8 0.5 2.3 0.4 257 15 235 255 0 0 0 0 6.1 0.2 6.7 5.7 04/28/2005 06:30:00 1.4 0.6 2.6 0.4 1.2 0.6 3 0.4 0.9 0.5 1.9 0.4 343 41 305 255 0 0 0 0 7 0 7.3 6.7 04/28/2005 06:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 331 7 330 255 0 0 0 0 7.6 0.3 8.5 7.3 04/28/2005 06:50:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 281 43 301 255 0 0 0 0 8.9 0.3 9.6 8.5 04/28/2005 07:00:00 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 1 0.6 2.6 0.4 306 13 318 255 0 0 0 0 10 0.2 10.6 9.6 04/28/2005 07:10:00 1.5 0.7 3 0.4 1.3 0.6 2.6 0.4 1.2 0.7 2.6 0.4 299 20 331 255 0 0 0 0 10.6 0.1 10.9 10.3 04/28/2005 07:20:00 1.8 0.7 3.8 0.4 1.7 0.7 3.4 0.4 1.5 0.7 3 0.4 281 33 242 255 0 0 0 0 11.2 0.1 11.4 10.9 04/28/2005 07:30:00 1.9 0.8 3.8 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3.4 0.4 313 45 355 255 0 0 0 0 11.4 0.1 11.9 11.1 04/28/2005 07:40:00 2.1 0.5 3.8 1.1 1.9 0.5 3.4 0.7 1.8 0.5 3 0.4 309 15 312 255 0 0 0 0 11.5 0.2 12.2 11.1 04/28/2005 07:50:00 2.6 0.5 3.8 0.7 2.5 0.6 3.8 0.4 2.3 0.6 4.2 0.4 311 13 297 255 0 0 0 0 11.3 0.1 11.9 11.1 04/28/2005 08:00:00 1.8 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.5 0.7 3 0.4 307 19 324 255 0 0 0 0 11.3 0.1 11.7 11.1 04/28/2005 08:10:00 2.4 0.7 4.2 0.7 2.3 0.9 3.8 0.4 2.3 0.8 4.2 0.4 301 17 292 255 0 0 0 0 11.7 0.1 12.2 11.4 04/28/2005 08:20:00 2.1 1.2 4.2 0.4 2 1.2 4.2 0.4 1.8 1.2 4.2 0.4 278 45 308 255 0 0 0 0 11.9 0.3 13 11.4 04/28/2005 08:30:00 2.1 0.7 3.4 0.4 2 0.7 3.4 0.4 1.7 0.8 3.4 0.4 310 26 275 255 0 0 0 0 12.9 0.1 13.3 12.7 04/28/2005 08:40:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.7 2.2 0.7 3.8 0.4 307 12 297 255 0 0 0 0 12.9 0.1 13.3 12.7 04/28/2005 08:50:00 2.7 0.7 4.2 0.4 2.6 0.7 4.2 0.4 2.4 0.6 3.8 0.7 312 11 319 255 0 0 0 0 13.2 0 13.5 13 04/28/2005 09:00:00 2.2 0.8 3.8 0.4 2 0.8 3.4 0.4 1.6 0.9 3.4 0.4 313 20 332 255 0 0 0 0 13.9 0.4 14.9 13.3 04/28/2005 09:10:00 2.5 0.6 3.8 0.7 2.4 0.6 3.8 0.4 2.3 0.6 4.2 0.7 270 17 272 255 0 0 0 0 14.7 0.2 15.5 14.4 04/28/2005 09:20:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.7 3 0.4 308 18 309 255 0 0 0 0 14.5 0 14.9 14.4 04/28/2005 09:30:00 1.6 0.8 3.8 0.4 1.4 0.8 3.4 0.4 1.3 0.8 3.4 0.4 349 33 349 255 0 0 0 0 15.3 0.2 15.7 14.6 04/28/2005 09:40:00 1.9 0.6 3.8 0.4 1.7 0.6 3.8 0.4 1.5 0.6 3.4 0.4 309 45 291 255 0 0 0 0 15.2 0.1 15.7 14.9 04/28/2005 09:50:00 2.5 0.7 4.6 0.4 2.4 0.7 4.2 0.4 2.2 0.9 3.8 0.4 301 17 290 255 0 0 0 0 15.2 0.2 15.7 14.9 04/28/2005 10:00:00 2.2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.8 0.9 3.4 0.4 313 24 278 255 0 0 0 0 15.3 0.3 16 14.9 04/28/2005 10:10:00 1.9 0.9 3.8 0.4 1.7 0.8 3.4 0.4 1.8 0.8 4.2 0.4 334 22 329 255 0 0 0 0 16.3 0.2 17.1 16 04/28/2005 10:20:00 1.7 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.6 0.8 3.4 0.4 316 32 355 255 0 0 0 0 16.7 0.2 17.1 16.3 04/28/2005 10:30:00 2.5 0.7 4.2 0.7 2.5 0.8 4.6 0.4 2.4 0.9 4.6 0.4 313 33 305 255 0 0 0 0 16.8 0 17.1 16.6 04/28/2005 10:40:00 2.5 0.6 4.2 0.7 2.5 0.7 4.2 0.4 2.3 0.6 3.8 0.7 297 15 297 255 0 0 0 0 16.6 0.2 17.1 16.3 04/28/2005 10:50:00 1.9 1 4.2 0.4 1.7 0.9 4.2 0.4 1.6 1 3.8 0.4 307 33 317 255 0 0 0 0 17 0.2 17.7 16.6 04/28/2005 11:00:00 2.2 0.8 3.8 0.4 2.1 0.8 3.8 0.4 1.8 0.9 3.8 0.4 304 16 320 255 0 0 0 0 17.4 0.2 18 17.1 04/28/2005 11:10:00 1.4 0.6 3 0.4 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 325 24 358 255 0 0 0 0 17.7 0 18.2 17.4 04/28/2005 11:20:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 1.4 0.7 2.6 0.4 354 21 297 255 0 0 0 0 18.4 0.3 19.4 17.7 04/28/2005 11:30:00 1.3 0.8 2.6 0.4 1.1 0.7 3 0.4 1.3 0.7 3 0.4 358 28 5 255 0 0 0 0 19.5 0 20 19.1 04/28/2005 11:40:00 1.9 0.4 3 0.7 1.8 0.5 3 0.4 1.6 0.5 2.6 0.4 11 28 25 255 0 0 0 0 19.6 0.2 20.3 19.1 04/28/2005 11:50:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 307 36 332 255 0 0 0 0 20 0.1 20.5 19.4 04/28/2005 12:00:00 1.5 1 3.4 0.4 1.5 1 3.8 0.4 1.4 0.8 3.4 0.4 303 24 298 255 0 0 0 0 20.3 0.1 20.5 20 04/28/2005 12:10:00 1.8 0.7 3.4 0.4 1.7 0.8 3.8 0.4 1.4 0.7 3 0.4 328 41 301 255 0 0 0 0 20.8 0 21.1 20.3 04/28/2005 12:20:00 1.7 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.4 0.7 3 0.4 350 41 337 255 0 0 0 0 21.8 0.3 22.9 21.1 04/28/2005 12:30:00 2.2 0.8 4.2 0.4 2 0.8 3.8 0.4 1.9 0.7 4.6 0.4 329 61 315 255 0 0 0 0 22.5 0.2 23.2 22.3 04/28/2005 12:40:00 2 0.8 3.8 0.4 1.8 0.8 4.2 0.4 1.7 0.9 4.6 0.4 341 33 340 255 0 0 0 0 22.6 0.1 23.2 22.3 04/28/2005 12:50:00 2.2 0.8 4.6 0.4 2 0.8 4.2 0.4 1.8 0.8 3.8 0.4 315 36 341 255 0 0 0 0 23.1 0.3 23.8 22.6 04/28/2005 13:00:00 2.3 1 4.6 0.4 2.2 1 4.2 0.4 1.8 1.1 4.6 0.4 281 22 263 255 0 0 0 0 22.9 0.2 23.5 22.6 04/28/2005 13:10:00 2.6 0.8 4.6 0.4 2.5 0.9 4.6 0.4 2.2 1 4.6 0.4 273 28 295 255 0 0 0 0 23 0.5 23.8 22.3 04/28/2005 13:20:00 2.2 1.2 4.9 0.4 2.1 1.2 4.6 0.4 1.8 1.2 5.3 0.4 276 49 292 255 0 0 0 0 23.5 0 23.8 23.5 04/28/2005 13:30:00 2.9 1 4.9 0.4 2.9 1 4.6 0.4 2.5 1 4.6 0.4 275 27 309 255 0 0 0 0 23.5 0.1 24.1 23.2 04/28/2005 13:40:00 2.8 1.2 5.3 0.4 2.8 1.2 5.3 0.4 2.5 1 4.6 0.4 292 32 296 255 0 0 0 0 23.5 0.2 23.8 23.5 04/28/2005 13:50:00 3 1.1 6.1 0.4 2.9 1.1 6.1 0.4 2.6 1.2 6.1 0.4 295 20 293 255 0 0 0 0 23.8 0 24.1 23.5 04/28/2005 14:00:00 2.6 1 4.6 0.4 2.5 1 4.9 0.4 2.1 1 4.6 0.4 280 28 288 255 0 0 0 0 23.7 0.3 24.4 23.5 04/28/2005 14:10:00 3.1 1.1 6.1 0.4 3 1.1 6.1 0.4 2.7 1.1 5.3 0.4 302 22 298 255 0 0 0 0 24.6 0 25 24.4 04/28/2005 14:20:00 4.4 1.2 6.8 1.5 4.3 1.2 6.8 1.5 3.7 1.3 6.5 0.7 303 17 311 255 0 0 0 0 24.6 0.2 25 24.4 04/28/2005 14:30:00 3.9 1 6.5 1.5 3.8 1 6.5 1.5 3.3 1.1 6.1 0.7 294 22 300 255 0 0 0 0 24.9 0 25 24.7 04/28/2005 14:40:00 3.5 1.1 6.5 0.7 3.4 1.3 6.5 0.4 2.8 1.3 6.5 0.4 289 29 311 255 0 0 0 0 25 0 25.3 25 04/28/2005 14:50:00 4.5 1 6.8 2.3 4.5 1 6.8 1.5 3.9 1.1 6.1 0.4 288 15 295 255 0 0 0 0 24.6 0.1 25.3 24.4 04/28/2005 15:00:00 4.1 1.1 6.5 1.5 4.1 1 6.1 1.5 3.3 1.2 5.7 0.4 300 19 314 255 0 0 0 0 25 0.1 25.3 24.4 04/28/2005 15:10:00 4.5 0.8 6.5 2.3 4.5 0.8 6.5 2.3 3.8 1 6.1 1.1 304 18 308 255 0 0 0 0 24.7 0 25 24.4 04/28/2005 15:20:00 3.7 1.1 6.5 0.7 3.7 1.1 6.8 0.7 3.2 1.2 6.1 0.7 290 18 294 255 0 0 0 0 24.4 0 24.7 24.4 04/28/2005 15:30:00 2.8 1.1 6.1 0.4 2.7 1.2 6.5 0.4 2.2 1.2 6.1 0.4 307 24 259 255 0 0 0 0 25 0.3 25.6 24.7 04/28/2005 15:40:00 4.3 0.8 6.1 2.3 4.2 0.8 6.1 1.9 3.6 0.8 5.7 1.5 302 13 291 255 0 0 0 0 25 0 25.6 25 04/28/2005 15:50:00 4 1 6.5 1.5 4 1 6.5 0.7 3.4 1 6.5 1.1 296 17 288 255 0 0 0 0 24.7 0 25 24.4 04/28/2005 16:00:00 4.4 0.9 6.1 1.9 4.4 0.9 6.1 1.9 3.8 1.1 6.1 1.1 301 15 286 255 0 0 0 0 24.1 0.1 24.7 23.8 04/28/2005 16:10:00 4.9 0.9 7.2 2.6 4.9 1 7.2 2.3 4.1 1.1 6.8 1.5 299 13 291 255 0 0 0 0 24.1 0.1 24.4 23.8 04/28/2005 16:20:00 4.1 1 6.5 1.9 3.9 1 6.1 1.5 3.4 1 6.1 1.1 308 17 310 255 0 0 0 0 24 0 24.4 23.8 04/28/2005 16:30:00 3.4 1.3 7.2 0.4 3.3 1.3 6.8 0.4 2.8 1.3 6.1 0.4 296 21 337 255 0 0 0 0 24 0 24.4 23.8 04/28/2005 16:40:00 3.8 0.8 5.7 1.5 3.7 0.8 5.7 1.5 3.2 1 6.1 1.1 288 18 291 255 0 0 0 0 23.7 0 24.1 23.5 04/28/2005 16:50:00 3.1 1 5.3 0.7 3 1 5.3 0.4 2.5 1 4.9 0.4 311 18 302 255 0 0 0 0 23.6 0 23.8 23.5 04/28/2005 17:00:00 3.5 1.1 5.7 1.1 3.5 1.1 5.3 1.1 3 1.2 5.3 0.7 289 15 277 255 0 0 0 0 23.3 0.2 23.8 23.2 04/28/2005 17:10:00 3.8 1.2 6.5 0.4 3.6 1.2 6.1 0.7 3.2 1.3 5.3 0.4 305 16 320 255 0 0 0 0 23.3 0.1 23.8 23.2 04/28/2005 17:20:00 3.2 0.9 4.9 0.4 3.1 0.9 4.6 0.4 2.8 1 4.9 0.7 312 15 314 255 0 0 0 0 22.9 0 23.5 22.9 04/28/2005 17:30:00 2.7 0.7 4.6 0.7 2.6 0.7 4.9 0.4 2.1 0.9 4.2 0.4 284 17 274 255 0 0 0 0 22.6 0 22.9 22.3 04/28/2005 17:40:00 1.9 1 4.2 0.4 1.9 1.1 3.8 0.4 1.4 0.9 3.4 0.4 294 51 265 255 0 0 0 0 22.4 0 23.2 22.3 04/28/2005 17:50:00 2.6 0.9 4.6 0.7 2.4 0.9 4.6 0.7 2 0.9 4.2 0.4 347 20 340 255 0 0 0 0 22.4 0 22.6 22 04/28/2005 18:00:00 3.6 1.5 7.2 0.7 3.5 1.6 7.2 0.4 3 1.5 6.8 0.7 346 35 32 255 0 0 0 0 22 0 22.3 21.7 04/28/2005 18:10:00 4.1 1.2 6.8 1.1 4 1.2 6.8 0.7 3.4 1.2 6.1 0.4 33 36 26 255 0 0 0 0 21.9 0 22.3 21.7 04/28/2005 18:20:00 4.9 1 6.8 2.3 4.8 1 7.2 2.3 3.5 1.1 6.8 1.1 5 17 11 255 0 0 0 0 21.3 0.3 22 20.8 04/28/2005 18:30:00 5.7 1 8.4 3 5.6 1 8 2.6 4.8 1.2 8.4 1.9 28 11 29 255 0 0 0 0 20.8 0.2 21.4 20.5 04/28/2005 18:40:00 5.9 1 8.4 3.4 5.8 1 8.4 3.4 5 1.1 8.4 2.3 30 15 17 255 0 0 0 0 20.6 0.1 21.1 20.5 04/28/2005 18:50:00 6.6 1 9.1 4.2 6.5 1 8.8 3.4 5.8 1.1 8.8 2.6 39 12 62 255 0 0 0 0 20.4 0 20.8 20.3 04/28/2005 19:00:00 6.9 1.3 10.3 3.4 6.9 1.5 10.7 3.4 6.1 1.5 10.3 2.6 37 12 40 255 0 0 0 0 19.9 0 20.5 19.7 04/28/2005 19:10:00 8.6 1.4 12.2 4.9 8.5 1.4 11.8 5.3 7.4 1.3 11.1 3.4 31 12 19 255 0 0 0 0 19.5 0 20 19.4 04/28/2005 19:20:00 7.3 1.1 10.3 4.6 7.3 1.2 10.3 4.2 6.3 1.2 9.5 3.8 34 11 21 255 0 0 0 0 19.2 0 19.4 19.1 04/28/2005 19:30:00 6.3 1.4 9.1 3 6.3 1.5 9.5 2.6 5.5 1.5 9.1 2.6 41 13 28 255 0 0 0 0 19 0 19.4 18.8 04/28/2005 19:40:00 5 1.1 8.4 2.3 4.9 1.2 8.4 2.3 4.3 1 7.6 2.3 75 22 62 255 0 0 0 0 18.7 0 19.4 18.5 04/28/2005 19:50:00 6.8 1.7 10.7 3 6.6 1.7 10.7 2.6 5.7 1.5 10.3 2.3 62 20 53 255 0 0 0 0 18.8 0 19.1 18.5 04/28/2005 20:00:00 6.3 1.7 10.3 2.3 6.3 1.7 10.7 2.3 5.4 1.7 9.9 1.5 54 17 51 255 0 0 0 0 18.9 0 19.1 18.5 04/28/2005 20:10:00 5 1.1 8.8 2.3 5 1 8.4 2.3 4.2 1 7.2 2.3 72 20 42 255 0 0 0 0 18.7 0.2 19.1 18.2 04/28/2005 20:20:00 5.3 1.1 8.4 2.3 5.3 1.1 8.8 3 4.5 1 7.6 1.9 73 17 60 255 0 0 0 0 18.2 0 18.2 18 04/28/2005 20:30:00 5.9 1.2 9.1 2.6 5.9 1.2 9.1 2.3 4.8 1.1 7.6 2.3 74 16 92 255 0 0 0 0 18.1 0 18.2 18 04/28/2005 20:40:00 5.6 1.3 9.1 3.4 5.6 1.3 9.5 3.4 4.7 1.2 8 1.5 79 15 92 255 0 0 0 0 18 0 18.2 17.7 04/28/2005 20:50:00 5.9 1 8.4 2.6 5.9 1 8.4 3 4.8 1 7.2 2.6 79 17 70 255 0 0 0 0 18 0 18.2 17.7 04/28/2005 21:00:00 5.8 1 8.4 3.4 5.8 1.1 8.4 3.4 4.9 1.1 7.6 2.3 83 12 73 255 0 0 0 0 18 0 18.2 17.7 04/28/2005 21:10:00 4.4 1 7.2 2.3 4.4 1 7.6 2.3 3.9 1.1 8.4 1.5 75 15 86 255 0 0 0 0 18.1 0 18.5 17.7 04/28/2005 21:20:00 4.9 0.8 7.2 2.6 4.9 0.9 7.2 2.6 3.9 0.9 6.5 2.3 84 13 66 255 0 0 0 0 17.6 0.1 18.2 17.4 04/28/2005 21:30:00 5.9 1.3 9.1 3.4 5.9 1.3 9.9 3.4 5.1 1.3 8.8 2.3 81 13 85 255 0 0 0 0 17.6 0 18.2 17.4 04/28/2005 21:40:00 7.3 2.4 13.3 2.6 7.3 2.4 13 2.6 6.3 2.3 12.6 1.9 81 17 90 255 0 0 0 0 18.2 0.1 18.5 17.7 04/28/2005 21:50:00 5.4 1.5 8.8 1.1 5.6 1.5 9.1 1.5 4.4 1.4 9.1 1.1 83 18 96 255 0 0 0 0 17.9 0 18.2 17.7 04/28/2005 22:00:00 6.7 2 11.5 2.6 6.6 2 11.8 1.1 5.4 1.8 10.3 1.5 84 21 105 255 0 0 0 0 17.8 0 18 17.7 04/28/2005 22:10:00 6.4 1.8 11.5 2.3 6.4 1.7 11.1 1.9 5.3 1.6 9.5 1.1 84 16 100 255 0 0 0 0 17.7 0 18 17.4 04/28/2005 22:20:00 6.9 1.5 11.1 3.8 6.9 1.6 11.5 4.2 5.7 1.5 9.9 2.3 80 15 63 255 0 0 0 0 17.5 0 17.7 17.4 04/28/2005 22:30:00 6.3 1.5 11.1 3.8 6.3 1.6 11.1 3.4 5.3 1.4 9.9 2.6 71 18 62 255 0 0 0 0 17.4 0 17.7 17.1 04/28/2005 22:40:00 6.1 1.5 9.5 3 6.1 1.5 9.9 2.6 5.1 1.5 8.4 2.3 79 15 87 255 0 0 0 0 17.3 0 17.7 17.1 04/28/2005 22:50:00 6.2 1.5 9.9 2.3 6.2 1.5 9.9 1.5 5.1 1.6 9.5 0.7 81 18 118 255 0 0 0 0 17.3 0 17.4 17.1 04/28/2005 23:00:00 5.3 1.7 8.8 2.3 5.2 1.7 8.8 1.9 4.3 1.6 9.1 1.5 70 17 55 255 0 0 0 0 17.2 0 17.4 16.8 04/28/2005 23:10:00 4.7 1.2 7.6 1.9 4.7 1.3 7.6 1.9 3.9 1.3 7.6 1.1 62 16 68 255 0 0 0 0 16.8 0 17.1 16.8 04/28/2005 23:20:00 6.2 1.6 11.1 2.3 6.1 1.6 10.7 1.9 5.1 1.6 9.1 1.5 70 17 76 255 0 0 0 0 16.8 0 17.1 16.8 04/28/2005 23:30:00 6.6 1.7 12.2 2.3 6.5 1.7 11.8 1.9 5.3 1.7 9.9 1.9 79 20 79 255 0 0 0 0 17 0 17.4 16.8 04/28/2005 23:40:00 5.6 1.5 8.8 2.6 5.6 1.5 8.8 2.6 4.6 1.3 8 1.9 84 15 88 255 0 0 0 0 16.8 0 17.1 16.6 04/28/2005 23:50:00 6.1 1.2 9.1 2.6 6.1 1.2 8.8 2.6 4.9 1.3 8.8 1.5 89 15 86 255 0 0 0 0 16.5 0.1 16.8 16.3 04/29/2005 00:00:00 6.2 1.5 10.7 3.4 6.2 1.5 10.7 3 5.2 1.6 10.7 1.9 88 17 91 255 0 0 0 0 16.6 0 17.1 16.3 04/29/2005 00:10:00 6.2 1.7 10.7 2.6 6.2 1.7 10.7 1.9 5.2 1.7 9.5 1.5 82 16 90 255 0 0 0 0 16.8 0 17.1 16.6 04/29/2005 00:20:00 5.4 1.2 8.4 2.6 5.4 1.2 8.4 2.6 4.4 1.2 8 1.5 81 19 77 255 0 0 0 0 16.5 0.2 16.8 16.3 04/29/2005 00:30:00 5.1 1.3 8.8 0.4 5.2 1.3 8.8 1.1 4.2 1.4 8 1.5 78 18 94 255 0 0 0 0 16.2 0.1 16.8 16 04/29/2005 00:40:00 4.8 1.2 7.6 1.1 4.9 1.2 8.4 1.1 4.1 1.1 7.2 0.7 79 17 64 255 0 0 0 0 15.9 0.2 16.6 15.7 04/29/2005 00:50:00 5.2 1.2 9.1 2.6 5.3 1.1 9.1 3 4.4 1.3 8.8 1.5 86 13 84 255 0 0 0 0 15.7 0.1 16.3 15.5 04/29/2005 01:00:00 4.8 1.3 8 1.5 4.9 1.2 7.6 2.3 3.9 1.3 7.6 1.1 91 16 99 255 0 0 0 0 15.5 0 16 15.5 04/29/2005 01:10:00 5.5 1.3 9.5 2.6 5.5 1.3 9.1 2.6 4.7 1.3 9.1 1.9 80 15 65 255 0 0 0 0 15.5 0 16 15.2 04/29/2005 01:20:00 5.2 1.1 8.4 2.3 5.2 1.1 8.4 2.3 4.1 1 7.2 1.5 87 16 87 255 0 0 0 0 15.4 0.1 15.7 15.2 04/29/2005 01:30:00 5.6 1.3 9.1 1.9 5.6 1.4 9.1 1.5 4.7 1.5 9.1 0.7 97 15 113 255 0 0 0 0 15.2 0 15.7 15.2 04/29/2005 01:40:00 5.7 1.2 8.4 3 5.7 1.2 8.4 2.3 4.6 1.3 7.6 1.1 100 17 110 255 0 0 0 0 15.2 0 15.7 15.2 04/29/2005 01:50:00 5.7 1.1 8 3.4 5.6 1.1 8.4 3 4.5 1.1 7.6 1.9 101 13 115 255 0 0 0 0 15.3 0 15.7 15.2 04/29/2005 02:00:00 6.2 1.3 9.1 2.6 6.1 1.3 9.1 2.6 5.3 1.2 8.4 2.3 100 14 113 255 0 0 0 0 15.1 0 15.7 15.2 04/29/2005 02:10:00 6.3 1.2 9.1 3 6.3 1.2 9.1 2.6 5.4 1.3 8.8 1.9 97 15 87 255 0 0 0 0 15.1 0 15.7 15.2 04/29/2005 02:20:00 5.8 1.2 8.8 2.6 5.8 1.2 8.4 2.6 4.8 1.2 8.4 1.5 99 14 136 255 0 0 0 0 14.8 0.1 15.2 14.6 04/29/2005 02:30:00 5.9 1.1 9.1 3 5.9 1.1 8.4 2.3 4.7 1 7.6 2.6 98 14 102 255 0 0 0 0 14.6 0 15.2 14.6 04/29/2005 02:40:00 5 1 7.2 2.6 5 1 7.2 2.3 4 0.9 6.5 1.9 96 12 98 255 0 0 0 0 14.4 0 14.9 14.1 04/29/2005 02:50:00 5.2 1 8.4 2.6 5.1 1 8 2.6 4 1.1 8 1.5 97 12 88 255 0 0 0 0 14 0 14.6 13.8 04/29/2005 03:00:00 5.2 1 8.4 3 5.2 1 8.8 3 4.5 1 7.2 1.9 100 12 96 255 0 0 0 0 14.1 0 14.6 13.8 04/29/2005 03:10:00 5.1 1.1 8 1.9 5 1.1 7.6 1.5 4.1 1.1 7.2 0.7 104 13 95 255 0 0 0 0 14 0.1 14.6 13.8 04/29/2005 03:20:00 5.2 0.8 7.6 3 5.1 0.8 7.2 2.6 4.2 0.9 6.5 1.9 103 11 119 255 0 0 0 0 13.8 0 14.4 13.5 04/29/2005 03:30:00 5 1.1 8 2.3 4.9 1.1 7.2 2.3 3.9 1.1 6.8 1.5 98 13 99 255 0 0 0 0 13.9 0 14.4 13.8 04/29/2005 03:40:00 5 1.1 8.4 2.6 5 1 8 2.3 4.1 1 6.5 1.5 99 13 97 255 0 0 0 0 13.8 0 14.4 13.5 04/29/2005 03:50:00 5.2 1 8 2.6 5.1 1 7.6 2.6 4.1 1 6.5 1.1 91 11 87 255 0 0 0 0 13.9 0 14.4 13.5 04/29/2005 04:00:00 4.7 1.2 7.6 1.9 4.6 1.2 8 1.5 3.8 1.1 6.8 1.1 99 18 96 255 0 0 0 0 13.8 0 14.6 13.5 04/29/2005 04:10:00 4.8 1.1 7.2 1.9 4.8 1.1 7.2 1.9 4.1 1.1 7.2 1.1 81 16 62 255 0 0 0 0 13.9 0 14.4 13.8 04/29/2005 04:20:00 5.2 1.2 9.5 2.6 5.1 1.2 9.5 2.6 4.3 1.1 8.8 1.9 86 17 90 255 0 0 0 0 13.8 0 14.4 13.5 04/29/2005 04:30:00 6.2 1.3 9.1 3 6.1 1.2 9.1 3 5.1 1.3 8.8 2.3 96 15 99 255 0 0 0 0 13.7 0 14.4 13.5 04/29/2005 04:40:00 5.7 1.3 9.1 3 5.7 1.3 8.8 2.6 4.7 1.2 7.6 1.9 99 16 124 255 0 0 0 0 13.8 0 14.4 13.5 04/29/2005 04:50:00 5.3 1.2 8.8 2.3 5.2 1.2 8.4 2.3 4.2 1.2 7.2 1.1 100 17 97 255 0 0 0 0 13.7 0 14.4 13.5 04/29/2005 05:00:00 5.3 1.3 8.4 2.6 5.3 1.2 8 2.6 4.4 1.3 7.6 1.1 104 14 91 255 0 0 0 0 13.7 0 14.4 13.5 04/29/2005 05:10:00 5.8 1.3 9.1 3 5.7 1.3 9.5 3 4.7 1.2 8 1.9 109 16 115 255 0 0 0 0 13.9 0 14.4 13.8 04/29/2005 05:20:00 5.9 1.2 8.8 1.1 5.8 1.2 8.4 1.9 4.8 1.1 7.6 1.9 106 15 95 255 0 0 0 0 14 0 14.6 13.8 04/29/2005 05:30:00 6.4 1.2 8.8 3.4 6.4 1.2 9.1 3.4 5.4 1.2 8.4 2.6 112 14 121 255 0 0 0 0 14.2 0 14.6 14.1 04/29/2005 05:40:00 6.5 1.3 9.9 3 6.5 1.2 9.5 3 5.3 1.2 8.4 2.6 113 15 117 255 0 0 0 0 14.5 0 14.6 14.4 04/29/2005 05:50:00 6.2 1.2 9.1 3.4 6.1 1.2 8.8 3 5.3 1.1 8 1.9 104 13 98 255 0 0 0 0 14.8 0 15.2 14.6 04/29/2005 06:00:00 6.6 1.5 9.9 2.6 6.6 1.5 9.9 2.6 5.3 1.3 8.4 1.9 98 15 109 255 0 0 0 0 14.6 0 14.9 14.6 04/29/2005 06:10:00 6 1.5 9.5 2.6 6 1.4 9.1 2.6 5.2 1.4 8.8 2.3 101 15 93 255 0 0 0 0 14.8 0 15.2 14.6 04/29/2005 06:20:00 5.6 1.2 9.1 2.6 5.6 1.3 8.8 2.3 4.7 1.1 8.4 1.5 102 15 109 255 0 0 0 0 14.8 0 15.2 14.6 04/29/2005 06:30:00 5.4 1.1 8.4 2.3 5.3 1.1 8 2.3 4.6 1.2 7.2 1.9 104 15 110 255 0 0 0 0 15 0.1 15.7 14.9 04/29/2005 06:40:00 6.4 1.4 10.7 1.5 6.3 1.5 10.7 2.3 5.4 1.5 8.4 1.5 98 16 117 255 0 0 0 0 15.1 0.1 15.7 14.9 04/29/2005 06:50:00 5.8 1.3 9.1 2.6 5.9 1.3 9.1 2.6 5 1.5 8.8 1.9 107 17 102 255 0 0 0 0 15.2 0.2 15.7 15.2 04/29/2005 07:00:00 6.1 1.3 9.5 3 6 1.3 9.5 3 5.2 1.3 8.4 2.3 101 17 97 255 0 0 0 0 15.6 0.1 16.3 15.5 04/29/2005 07:10:00 5.8 1.3 9.1 2.6 5.8 1.3 9.1 2.3 5 1.3 8.4 2.3 98 16 100 255 0 0 0 0 15.9 0 16.6 15.7 04/29/2005 07:20:00 5.9 1.1 8.4 3 5.9 1.1 8 2.6 5 1.3 8.8 1.9 100 16 113 255 0 0 0 0 16.1 0 16.8 16 04/29/2005 07:30:00 5.9 1.3 8.4 2.6 5.8 1.3 8.8 1.9 5.2 1.2 8 2.3 97 13 97 255 0 0 0 0 16.4 0 16.8 16.3 04/29/2005 07:40:00 5.3 1 8 2.3 5.2 1.1 8.4 2.6 4.6 1.2 7.2 1.5 99 14 105 255 0 0 0 0 16.7 0 16.8 16.6 04/29/2005 07:50:00 5.3 1 8 2.3 5.2 1 8 2.3 4.5 1.1 7.6 2.3 104 15 89 255 0 0 0 0 16.8 0 17.4 16.6 04/29/2005 08:00:00 4.9 1.3 8.8 1.5 4.8 1.3 8.4 1.9 4.2 1.2 8 1.9 108 16 124 255 0 0 0 0 17.3 0.1 17.7 16.8 04/29/2005 08:10:00 5.5 1.3 10.3 3 5.5 1.3 9.9 2.6 4.8 1.3 9.5 2.3 104 17 128 255 0 0 0 0 17.4 0.1 17.7 17.1 04/29/2005 08:20:00 5.1 1.2 8.4 1.5 5 1.2 8.8 1.5 4.7 1.1 7.6 1.9 109 16 129 255 0 0 0 0 17.5 0 17.7 17.1 04/29/2005 08:30:00 4.3 1.5 8.8 1.5 4.2 1.5 8.8 1.1 3.9 1.3 8 1.1 110 17 103 255 0 0 0 0 17.8 0 18 17.4 04/29/2005 08:40:00 4.8 1.3 7.6 1.9 4.7 1.3 7.6 1.9 4.1 1.3 7.6 0.7 111 17 119 255 0 0 0 0 18.1 0 18.5 17.7 04/29/2005 08:50:00 4.2 1.3 7.6 1.5 4.2 1.4 7.2 1.1 3.7 1.5 7.2 0.7 93 16 93 255 0 0 0 0 18.6 0.3 19.4 18 04/29/2005 09:00:00 4.7 0.9 6.8 1.9 4.6 1 7.2 1.1 4.1 0.9 6.5 1.1 100 14 109 255 0 0 0 0 19.2 0 19.4 19.1 04/29/2005 09:10:00 4.2 1.2 7.2 1.5 4.1 1.2 7.2 1.5 3.8 1.3 6.8 0.4 98 18 119 255 0 0 0 0 19.5 0.1 20 19.1 04/29/2005 09:20:00 5 1 8 2.6 5 1 7.6 3 4.4 1 7.2 1.1 90 13 90 255 0 0 0 0 20 0 20.5 20 04/29/2005 09:30:00 4.5 1.1 6.8 1.9 4.5 1.2 6.8 1.1 3.9 1.2 6.8 1.1 88 15 89 255 0 0 0 0 20.5 0.1 21.1 20.3 04/29/2005 09:40:00 4.7 1.3 7.6 1.1 4.6 1.3 7.6 1.5 4.1 1.3 8 0.7 86 20 108 255 0 0 0 0 20.8 0.2 21.1 20.5 04/29/2005 09:50:00 5.1 1.2 8 2.6 5.1 1.2 8 2.3 4.8 1.2 7.6 1.9 88 17 103 255 0 0 0 0 20.8 0.2 21.1 20.5 04/29/2005 10:00:00 4.3 1.5 8 0.7 4.2 1.6 8 0.7 3.8 1.5 7.2 0.4 86 22 90 255 0 0 0 0 20.7 0.2 21.7 20.3 04/29/2005 10:10:00 4.9 1.3 8.8 1.5 4.9 1.3 8.4 1.9 4.5 1.3 8.8 1.5 102 17 112 255 0 0 0 0 21 0.1 21.7 20.8 04/29/2005 10:20:00 4.5 1.3 7.6 1.9 4.5 1.3 7.2 1.5 4 1.4 7.2 1.1 95 17 101 255 0 0 0 0 20.8 0 21.4 20.5 04/29/2005 10:30:00 3.8 1 6.5 1.1 3.8 1.1 7.6 0.7 3.5 1 5.7 0.7 89 29 159 255 0 0 0 0 21.6 0.2 22.3 21.1 04/29/2005 10:40:00 3.6 1.2 6.5 1.1 3.5 1.2 6.5 0.4 3.2 1.3 6.5 0.4 83 27 83 255 0 0 0 0 22.1 0.2 22.9 21.7 04/29/2005 10:50:00 4.1 1 6.8 1.5 4 1 6.8 1.5 3.5 1.1 6.5 0.4 94 26 78 255 0 0 0 0 21.7 0.1 22.3 21.4 04/29/2005 11:00:00 4.2 0.9 6.8 1.5 4.1 0.9 6.5 1.9 3.7 1 6.5 0.7 98 16 102 255 0 0 0 0 21.7 0 22.3 21.4 04/29/2005 11:10:00 3.7 1.1 6.5 1.5 3.7 1 6.5 1.5 3.3 1 5.7 1.1 103 26 116 255 0 0 0 0 21.5 0 22 21.1 04/29/2005 11:20:00 3.1 0.8 4.9 1.1 3 0.8 4.6 1.1 2.6 1 4.6 0.7 105 26 84 255 0 0 0 0 21.7 0 22 21.4 04/29/2005 11:30:00 4 1 6.1 1.9 4 1 6.1 1.9 3.6 1.1 5.7 0.4 60 18 57 255 0 0 0 0 22 0 22.9 21.7 04/29/2005 11:40:00 3.6 1.1 6.5 1.1 3.6 1.1 6.5 1.1 3.1 0.9 5.3 0.4 38 17 21 255 0 0 0 0 22.9 0.3 23.5 22.3 04/29/2005 11:50:00 4.5 1 6.8 2.3 4.5 0.9 7.2 2.3 3.7 1 6.5 1.5 34 16 42 255 0 0 0 0 23 0.2 23.5 22.6 04/29/2005 12:00:00 4 1.1 6.8 1.5 4 1.1 6.8 1.5 3.4 1 6.5 1.1 35 15 24 255 0 0 0 0 23.4 0 23.8 23.2 04/29/2005 12:10:00 4.8 1 6.8 2.6 4.8 1 6.8 2.3 3.8 1 6.1 1.5 23 18 11 255 0 0 0 0 23.7 0.1 24.1 23.5 04/29/2005 12:20:00 4.2 0.8 6.1 1.5 4.2 0.8 6.1 1.5 3.4 0.9 5.3 0.7 31 20 20 255 0 0 0 0 24 0.1 24.7 23.8 04/29/2005 12:30:00 3.6 1.3 6.5 0.4 3.6 1.3 6.5 0.4 2.7 1.4 6.1 0.4 15 26 351 255 0 0 0 0 23.9 0.2 24.7 23.5 04/29/2005 12:40:00 3.1 1 6.5 0.7 3 1 6.5 0.4 2.6 1 4.9 0.4 59 24 26 255 0 0 0 0 24.1 0.1 24.7 23.8 04/29/2005 12:50:00 2.7 1 5.3 1.1 2.6 1 5.3 0.7 2.2 1.1 4.9 0.4 93 22 72 255 0 0 0 0 24 0.1 24.4 23.5 04/29/2005 13:00:00 3.3 1.2 6.1 0.4 3.2 1.3 6.1 0.4 2.8 1.1 5.3 0.4 77 38 33 255 0 0 0 0 23.8 0.2 24.1 23.5 04/29/2005 13:10:00 2.1 1.3 5.7 0.4 1.9 1.3 5.3 0.4 1.5 1.2 4.9 0.4 288 94 44 255 0 0 0 0 24.1 0.4 25 23.5 04/29/2005 13:20:00 2.9 1.6 7.2 0.4 2.9 1.5 7.6 0.4 2.5 1.4 6.5 0.4 52 29 69 255 0 0 0 0 24.6 0.1 25 24.1 04/29/2005 13:30:00 3.3 1.2 6.1 0.7 3.3 1.2 6.1 0.4 2.7 1.1 5.7 0.4 18 21 17 255 0 0 0 0 24.7 0 25.3 24.4 04/29/2005 13:40:00 2.7 1.2 5.3 0.4 2.7 1.2 4.9 0.4 2.4 1.1 5.3 0.4 43 28 27 255 0 0 0 0 24.8 0 25.3 24.7 04/29/2005 13:50:00 2.8 1.1 5.3 0.4 2.7 1.1 5.3 0.4 2.1 1 4.6 0.4 30 24 26 255 0 0 0 0 25 0.1 25.3 25 04/29/2005 14:00:00 3.7 1 6.1 1.9 3.6 1 6.1 1.9 3 0.8 5.3 1.1 34 23 12 255 0 0 0 0 25.2 0 25.6 25 04/29/2005 14:10:00 3.1 0.8 4.9 0.7 3.1 0.8 4.9 0.4 2.7 1 6.1 0.4 53 32 56 255 0 0 0 0 24.5 0.1 25 24.1 04/29/2005 14:20:00 1.7 1.2 4.6 0.4 1.6 1.1 4.9 0.4 1.3 1.1 4.6 0.4 44 79 357 255 0 0 0 0 24.9 0 25 24.7 04/29/2005 14:30:00 2 1.1 4.6 0.4 1.9 1.1 4.6 0.4 1.7 1 4.2 0.4 89 72 47 255 0 0 0 0 25.1 0 25.3 25 04/29/2005 14:40:00 1.4 1.2 4.6 0.4 1.4 1.2 4.9 0.4 1.2 1.1 4.6 0.4 92 72 99 255 0 0 0 0 24.9 0 25.3 25 04/29/2005 14:50:00 2.5 1.3 6.1 0.4 2.5 1.2 6.1 0.4 2.4 1.2 6.1 0.4 72 53 53 255 0 0 0 0 25 0.1 25.6 24.7 04/29/2005 15:00:00 3.1 0.9 4.9 0.7 2.9 0.9 4.9 0.4 2.4 1.1 4.6 0.4 341 17 347 255 0 0 0 0 26 0.1 26.5 25.6 04/29/2005 15:10:00 3.6 0.9 6.1 1.5 3.3 0.9 5.7 1.1 2.9 1 5.7 0.4 331 19 345 255 0 0 0 0 25.6 0 25.9 25.3 04/29/2005 15:20:00 2.8 1.2 5.7 0.4 2.7 1.2 6.1 0.4 1.9 1.1 5.3 0.4 322 51 334 255 0 0 0 0 25.8 0 26.2 25.3 04/29/2005 15:30:00 3 1.8 7.6 0.4 2.8 1.7 6.8 0.4 2.5 1.9 6.8 0.4 329 51 317 255 0 0 0 0 25.4 0 25.6 25.3 04/29/2005 15:40:00 3.9 1.3 6.8 1.1 3.8 1.3 6.5 0.4 3.1 1.5 6.5 0.4 287 29 267 255 0 0 0 0 25 0 25.3 25 04/29/2005 15:50:00 4.6 1 7.6 2.3 4.6 1 7.2 1.9 4.1 1.1 7.2 1.9 292 15 293 255 0 0 0 0 24.8 0 25 24.7 04/29/2005 16:00:00 4.1 1 6.5 1.5 4.1 1 6.5 0.7 3.5 1.2 6.1 0.4 283 21 303 255 0 0 0 0 24.2 0.2 24.7 23.8 04/29/2005 16:10:00 3.8 0.8 6.1 1.1 3.8 0.8 6.1 1.5 3.2 1 5.7 0.4 293 14 291 255 0 0 0 0 24.1 0.1 24.4 23.8 04/29/2005 16:20:00 3.4 1 6.1 0.4 3.3 1.1 6.1 0.4 2.9 1.3 6.8 0.4 295 26 290 255 0 0 0 0 23.6 0 23.8 23.5 04/29/2005 16:30:00 4.5 1 6.8 2.3 4.4 1 7.2 2.3 3.6 1.1 6.8 0.7 311 15 315 255 0 0 0 0 23.5 0.1 23.8 23.5 04/29/2005 16:40:00 3.3 1.2 7.2 0.4 3.1 1.3 7.2 0.4 2.5 1.5 6.8 0.4 306 23 304 255 0 0 0 0 23.5 0 23.8 23.5 04/29/2005 16:50:00 4.5 0.8 7.2 2.3 4.5 0.9 6.5 1.9 3.7 1 6.1 1.1 281 17 298 255 0 0 0 0 23 0.2 23.5 22.9 04/29/2005 17:00:00 3.9 0.9 6.1 1.5 3.8 0.9 6.1 1.1 3 0.9 5.3 0.7 285 19 260 255 0 0 0 0 22.8 0 23.2 22.9 04/29/2005 17:10:00 3 1 5.3 0.4 2.9 1.1 5.7 0.4 2.6 1.1 4.9 0.4 319 18 318 255 0 0 0 0 23 0.1 23.5 22.9 04/29/2005 17:20:00 3.5 0.6 5.3 1.1 3.4 0.6 4.9 1.5 2.7 0.7 4.2 0.7 291 17 293 255 0 0 0 0 22.7 0 23.5 22.3 04/29/2005 17:30:00 2.5 0.8 4.2 0.4 2.4 0.8 4.2 0.4 1.9 0.8 4.2 0.4 286 26 269 255 0 0 0 0 22.4 0 23.2 22.3 04/29/2005 17:40:00 2.5 1 4.9 0.4 2.3 1.1 4.9 0.4 2.1 1.1 4.6 0.4 292 22 296 255 0 0 0 0 22.4 0 22.6 22.3 04/29/2005 17:50:00 2.3 1.1 4.6 0.4 2.2 1.2 4.6 0.4 1.7 1.1 4.6 0.4 295 33 318 255 0 0 0 0 22.2 0 22.3 22 04/29/2005 18:00:00 1.6 0.7 3.4 0.4 1.4 0.7 3.4 0.4 0.9 0.6 3 0.4 320 38 287 255 0 0 0 0 22.1 0 22.6 22 04/29/2005 18:10:00 1 0.6 3 0.4 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 357 13 327 255 0 0 0 0 21.9 0.1 22.6 21.7 04/29/2005 18:20:00 2.2 0.8 3.8 0.4 2.1 0.8 3.4 0.4 1.4 0.8 3.4 0.4 351 28 27 255 0 0 0 0 21.7 0.1 22.3 21.4 04/29/2005 18:30:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.1 1.7 0.9 3.4 0.4 8 24 355 255 0 0 0 0 21.3 0 21.7 21.1 04/29/2005 18:40:00 3.8 1 5.7 1.5 3.8 0.9 6.1 1.5 3 1 4.9 1.1 20 15 8 255 0 0 0 0 21.3 0 21.7 20.8 04/29/2005 18:50:00 3.7 0.7 5.3 1.5 3.7 0.7 5.3 1.9 3 1 5.3 0.7 17 8 20 255 0 0 0 0 20.7 0.2 21.4 20.3 04/29/2005 19:00:00 3.5 0.7 4.9 1.9 3.4 0.7 5.3 1.5 2.7 0.7 4.2 0.7 20 9 8 255 0 0 0 0 20.3 0 20.8 20 04/29/2005 19:10:00 3.5 0.6 4.9 1.9 3.5 0.5 4.6 1.9 2.7 0.7 4.6 0.7 25 13 21 255 0 0 0 0 19.7 0.1 20.5 19.4 04/29/2005 19:20:00 2.9 0.6 4.2 0.7 2.8 0.7 4.2 0.4 2.2 0.8 3.8 0.4 29 17 23 255 0 0 0 0 19.7 0.1 20.3 19.4 04/29/2005 19:30:00 2.4 0.6 4.2 1.1 2.3 0.7 4.2 0.7 2 0.7 3.8 0.4 52 13 58 255 0 0 0 0 19.4 0 19.4 19.4 04/29/2005 19:40:00 3.1 0.5 4.2 1.5 3 0.6 4.6 1.5 2.4 0.6 4.2 1.1 49 11 59 255 0 0 0 0 19.2 0 19.4 19.1 04/29/2005 19:50:00 2.3 0.5 3.8 0.7 2.2 0.6 3.4 0.7 1.7 0.6 3 0.4 50 11 58 255 0 0 0 0 18.8 0 19.1 18.5 04/29/2005 20:00:00 1.9 0.6 3.8 0.4 1.8 0.7 3.8 0.4 1.3 0.6 3 0.4 59 10 54 255 0 0 0 0 18 0.2 18.5 17.7 04/29/2005 20:10:00 2.6 0.7 3.8 0.7 2.6 0.8 4.2 0.4 2.2 0.7 3.4 0.7 53 10 51 255 0 0 0 0 17.4 0 17.7 17.1 04/29/2005 20:20:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.7 1.6 0.7 3 0.4 57 13 55 255 0 0 0 0 17 0.1 17.4 16.6 04/29/2005 20:30:00 2.8 0.7 4.6 0.7 2.7 0.8 4.2 0.4 2.2 0.8 4.2 0.4 40 15 35 255 0 0 0 0 16.4 0.1 16.8 16.3 04/29/2005 20:40:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.8 0.6 3.4 0.4 47 15 32 255 0 0 0 0 16.1 0.2 16.8 15.7 04/29/2005 20:50:00 2.3 0.6 3.8 0.4 2.2 0.7 3.8 0.4 1.7 0.6 3 0.4 64 15 56 255 0 0 0 0 15.2 0.3 16.3 14.6 04/29/2005 21:00:00 2.7 0.5 4.2 1.1 2.6 0.6 4.2 1.1 1.9 0.5 3.4 0.4 54 13 63 255 0 0 0 0 14.6 0 15.2 14.6 04/29/2005 21:10:00 3.3 0.5 4.6 2.3 3.2 0.6 4.6 1.9 2.6 0.7 4.2 1.1 36 10 32 255 0 0 0 0 14.6 0.1 15.2 14.4 04/29/2005 21:20:00 2.2 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.4 0.6 3 0.4 71 20 69 255 0 0 0 0 13.4 0.6 14.9 12.5 04/29/2005 21:30:00 2.5 0.5 4.2 1.1 2.4 0.6 4.2 1.1 1.6 0.6 3.8 0.4 76 16 75 255 0 0 0 0 12.4 0 12.7 12.2 04/29/2005 21:40:00 2.2 0.6 3.8 0.4 2.2 0.6 3.8 0.4 1.3 0.7 3.4 0.4 60 16 35 255 0 0 0 0 12.4 0 12.7 12.2 04/29/2005 21:50:00 1.7 0.8 4.6 0.4 1.6 0.8 4.2 0.4 1 0.8 3.8 0.4 57 13 56 255 0 0 0 0 12.3 0 12.7 11.9 04/29/2005 22:00:00 2.2 0.6 3.4 1.1 2.1 0.6 3.4 0.7 1.5 0.5 3 0.4 65 10 66 255 0 0 0 0 12.1 0 12.5 11.9 04/29/2005 22:10:00 2 0.4 3 0.7 1.9 0.4 3 0.7 1.2 0.4 2.3 0.4 58 15 70 255 0 0 0 0 11.5 0.1 12.2 11.4 04/29/2005 22:20:00 2 0.5 3.4 0.7 1.8 0.5 3.4 0.4 1.2 0.6 2.6 0.4 50 8 55 255 0 0 0 0 11.1 0.3 11.9 10.3 04/29/2005 22:30:00 1.3 0.6 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 29 8 37 255 0 0 0 0 10 0 10.6 9.8 04/29/2005 22:40:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 0.7 0.4 1.9 0.4 45 11 43 255 0 0 0 0 10.2 0.1 10.6 9.8 04/29/2005 22:50:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 0.4 0.2 1.1 0.4 44 7 49 255 0 0 0 0 9.8 0.1 10.3 9.6 04/29/2005 23:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 79 18 52 255 0 0 0 0 9.6 0.1 10.1 9.3 04/29/2005 23:10:00 0.5 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 109 17 95 255 0 0 0 0 9.2 0.2 9.8 8.8 04/29/2005 23:20:00 1.1 0.5 2.6 0.4 1 0.5 2.6 0.4 0.7 0.4 2.3 0.4 142 12 145 255 0 0 0 0 8.7 0.2 9.3 8.5 04/29/2005 23:30:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 0.9 0.6 2.6 0.4 143 7 135 255 0 0 0 0 8.1 0.2 8.8 7.8 04/29/2005 23:40:00 0.7 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.5 0.4 1.9 0.4 131 2 130 255 0 0 0 0 7.7 0.1 8.5 7.5 04/29/2005 23:50:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 131 2 131 255 0 0 0 0 7.4 0.1 7.8 7.3 04/30/2005 00:00:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 151 21 136 255 0 0 0 0 7.3 0 7.5 7.3 04/30/2005 00:10:00 1.3 0.6 2.6 0.4 1.2 0.6 2.3 0.4 1.3 0.6 2.3 0.4 171 7 167 255 0 0 0 0 7.1 0.1 7.3 6.7 04/30/2005 00:20:00 1.7 0.5 2.6 0.7 1.5 0.5 2.3 0.7 1.5 0.3 1.9 0.7 143 7 152 255 0 0 0 0 6.7 0 7.3 6.7 04/30/2005 00:30:00 1.7 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.1 0.6 2.3 0.4 134 11 141 255 0 0 0 0 6.4 0 7 6.2 04/30/2005 00:40:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 131 9 111 255 0 0 0 0 6.1 0.1 6.7 5.7 04/30/2005 00:50:00 1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 141 9 140 255 0 0 0 0 5.7 0 6.2 5.7 04/30/2005 01:00:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 136 9 150 255 0 0 0 0 5.7 0 6.2 5.7 04/30/2005 01:10:00 2 0.5 3 1.1 1.8 0.6 3 0.7 1.7 0.8 3 0.4 144 7 148 255 0 0 0 0 5.7 0 5.7 5.5 04/30/2005 01:20:00 2 0.6 3 0.4 1.8 0.7 3 0.4 1.4 0.5 2.6 0.4 142 7 147 255 0 0 0 0 5.2 0.1 5.5 5 04/30/2005 01:30:00 2.3 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.2 0.6 2.6 0.4 115 19 143 255 0 0 0 0 5 0 5.5 5 04/30/2005 01:40:00 1.8 0.3 2.3 1.1 1.7 0.3 2.6 0.7 0.7 0.3 1.9 0.4 94 12 96 255 0 0 0 0 4.9 0 5 4.8 04/30/2005 01:50:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 67 4 75 255 0 0 0 0 4.9 0 5 4.8 04/30/2005 02:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 65 0 65 255 0 0 0 0 4.6 0.1 5 4.5 04/30/2005 02:10:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 65 0 65 255 0 0 0 0 4.6 0 5 4.5 04/30/2005 02:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 127 41 118 255 0 0 0 0 4.6 0 5 4.5 04/30/2005 02:30:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 136 17 124 255 0 0 0 0 4.4 0.2 5 4 04/30/2005 02:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 143 0 141 255 0 0 0 0 3.8 0.1 4.5 3.5 04/30/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 255 255 0 0 0 0 3.6 0.1 4 3.5 04/30/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 255 255 0 0 0 0 3.5 0.1 4.3 3.3 04/30/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 255 255 0 0 0 0 3.2 0 3.3 3 04/30/2005 03:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 132 35 25 255 0 0 0 0 3 0.1 3.3 2.8 04/30/2005 03:30:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 24 1 22 255 0 0 0 0 3 0 3.3 2.8 04/30/2005 03:40:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 0.4 0.1 1.1 0.4 43 9 27 255 0 0 0 0 2.9 0 3 2.8 04/30/2005 03:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 51 255 0 0 0 0 2.9 0 2.8 2.8 04/30/2005 04:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 72 19 80 255 0 0 0 0 2.7 0 2.8 2.3 04/30/2005 04:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 89 1 89 255 0 0 0 0 2.6 0 2.8 2.3 04/30/2005 04:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 86 255 0 0 0 0 2.4 0.1 2.6 2.3 04/30/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 255 255 0 0 0 0 2.2 0 2.3 2.1 04/30/2005 04:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 86 255 0 0 0 0 2.2 0 2.3 2.1 04/30/2005 04:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 109 23 87 255 0 0 0 0 2.1 0 2.3 2.1 04/30/2005 05:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 140 10 133 255 0 0 0 0 2.1 0.1 2.3 1.8 04/30/2005 05:10:00 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 125 5 134 255 0 0 0 0 1.9 0 2.1 1.8 04/30/2005 05:20:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 151 3 151 255 0 0 0 0 2 0.1 2.3 1.8 04/30/2005 05:30:00 1.5 0.6 2.6 0.4 1.4 0.7 2.6 0.4 0.9 0.5 1.9 0.4 140 28 142 255 0 0 0 0 2.1 0 2.3 1.8 04/30/2005 05:40:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.5 2.6 0.4 117 15 127 255 0 0 0 0 2.2 0 2.3 2.1 04/30/2005 05:50:00 0.4 0.1 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 2.3 0.4 115 0 115 255 0 0 0 0 2.7 0.3 3.3 2.3 04/30/2005 06:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 117 1 118 255 0 0 0 0 3.4 0.2 3.8 3 04/30/2005 06:10:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 125 5 128 255 0 0 0 0 4.1 0.2 4.5 3.8 04/30/2005 06:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 128 0 129 255 0 0 0 0 4.8 0.2 5.2 4.5 04/30/2005 06:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 121 20 129 255 0 0 0 0 5.7 0.2 6 5.2 04/30/2005 06:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 80 7 84 255 0 0 0 0 6.6 0.4 7.5 6 04/30/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 0 255 255 0 0 0 0 8.4 0.4 9.3 7.5 04/30/2005 07:00:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 10 28 358 255 0 0 0 0 9.8 0.1 10.3 9.3 04/30/2005 07:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 38 27 14 255 0 0 0 0 10.7 0.3 11.4 10.3 04/30/2005 07:20:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 355 22 357 255 0 0 0 0 11.3 0.2 11.9 11.1 04/30/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 299 94 255 255 0 0 0 0 12 0 12.5 11.7 04/30/2005 07:40:00 1 0.8 3 0.4 1 0.8 2.6 0.4 0.8 0.6 2.3 0.4 101 102 225 255 0 0 0 0 12.7 0.2 13.3 12.2 04/30/2005 07:50:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 259 30 216 255 0 0 0 0 13.3 0 13.5 13 04/30/2005 08:00:00 1.1 0.8 3 0.4 1 0.8 3 0.4 0.8 0.6 2.6 0.4 260 11 265 255 0 0 0 0 13.1 0.1 13.8 12.7 04/30/2005 08:10:00 1.1 0.7 3 0.4 1 0.7 3.4 0.4 0.9 0.7 2.6 0.4 293 61 261 255 0 0 0 0 14.1 0.2 14.6 13.5 04/30/2005 08:20:00 1.9 1 4.2 0.4 1.7 1 3.8 0.4 1.7 1 3.8 0.4 280 33 276 255 0 0 0 0 14.3 0 14.6 13.8 04/30/2005 08:30:00 1.3 0.6 3 0.4 1.1 0.5 2.6 0.4 1 0.6 3 0.4 275 36 307 255 0 0 0 0 14.6 0 14.9 14.4 04/30/2005 08:40:00 1.9 0.8 3.4 0.4 1.8 0.8 3.8 0.4 1.5 0.7 3.8 0.4 293 29 324 255 0 0 0 0 14.8 0 15.2 14.6 04/30/2005 08:50:00 2.2 0.9 4.2 0.4 2 0.9 4.2 0.4 1.7 0.9 3.8 0.4 306 22 289 255 0 0 0 0 14.6 0 14.9 14.6 04/30/2005 09:00:00 2 0.9 3.8 0.4 1.8 1 3.8 0.4 1.5 0.9 3.4 0.4 294 24 327 255 0 0 0 0 14.7 0.1 15.2 14.4 04/30/2005 09:10:00 2 0.7 3.8 0.4 1.9 0.7 3.4 0.4 1.7 0.7 3.8 0.4 293 26 257 255 0 0 0 0 15.1 0.1 15.7 14.9 04/30/2005 09:20:00 2.5 0.7 4.2 0.4 2.3 0.8 4.2 0.4 2.1 0.9 4.2 0.4 304 24 321 255 0 0 0 0 15.5 0.2 16 15.2 04/30/2005 09:30:00 2.6 0.7 4.2 0.4 2.5 0.7 3.8 0.4 2.1 0.8 3.8 0.4 287 24 283 255 0 0 0 0 15.3 0.2 15.7 14.9 04/30/2005 09:40:00 1.7 1 3.8 0.4 1.7 1 4.2 0.4 1.2 0.9 3.8 0.4 291 39 255 255 0 0 0 0 15.5 0.4 16.3 14.9 04/30/2005 09:50:00 2.5 0.7 3.8 0.4 2.3 0.8 3.8 0.4 2 0.8 3.4 0.4 303 26 286 255 0 0 0 0 15.7 0.1 16.3 15.7 04/30/2005 10:00:00 2.7 0.7 4.6 0.7 2.5 0.7 4.6 0.7 2.1 0.8 4.9 0.4 289 28 290 255 0 0 0 0 16.1 0 16.6 15.7 04/30/2005 10:10:00 2.6 0.5 3.8 1.1 2.5 0.6 4.2 1.1 2.4 0.8 4.6 0.4 287 17 271 255 0 0 0 0 15.7 0 16 15.5 04/30/2005 10:20:00 2.1 0.9 4.2 0.4 2.1 0.9 3.8 0.4 1.9 1 4.2 0.4 289 32 305 255 0 0 0 0 15.9 0.3 16.8 15.7 04/30/2005 10:30:00 2.4 0.8 3.8 0.4 2.1 0.8 3.4 0.4 1.9 0.9 3.8 0.4 320 12 328 255 0 0 0 0 16.7 0.3 17.4 16.3 04/30/2005 10:40:00 2.6 0.9 4.2 0.4 2.5 0.9 4.2 0.4 2.1 1.1 4.6 0.4 301 24 297 255 0 0 0 0 17.1 0.1 17.7 16.8 04/30/2005 10:50:00 2.4 0.8 4.6 0.7 2.3 0.8 4.6 0.4 2.2 0.8 4.2 0.4 314 23 285 255 0 0 0 0 17.2 0 17.7 16.8 04/30/2005 11:00:00 2.4 1 4.2 0.4 2.3 0.9 4.2 0.4 2 1 4.2 0.4 300 22 313 255 0 0 0 0 17.2 0.1 17.7 16.8 04/30/2005 11:10:00 2.1 0.8 4.6 0.4 2 0.8 4.2 0.4 1.7 1 3.8 0.4 304 24 299 255 0 0 0 0 17.4 0.1 18 17.1 04/30/2005 11:20:00 2.9 0.8 4.6 0.4 2.8 0.8 4.9 0.4 2.5 0.9 4.6 0.4 288 20 306 255 0 0 0 0 17.5 0.3 18.2 16.8 04/30/2005 11:30:00 2.6 0.9 4.6 0.4 2.5 0.9 4.6 0.4 2.1 0.9 4.2 0.4 298 22 295 255 0 0 0 0 18.2 0.2 18.8 17.4 04/30/2005 11:40:00 3 0.7 5.3 1.1 2.8 0.7 4.6 0.7 2.6 0.8 4.9 0.4 315 15 347 255 0 0 0 0 18.1 0.2 18.8 17.7 04/30/2005 11:50:00 2.9 1 4.9 0.4 2.8 1 4.9 0.4 2.5 1.1 4.9 0.4 305 17 301 255 0 0 0 0 18 0 18.2 17.7 04/30/2005 12:00:00 2.6 1 4.6 0.4 2.5 1 4.6 0.4 2 1 4.2 0.4 310 24 312 255 0 0 0 0 18.5 0.2 19.1 18 04/30/2005 12:10:00 2.9 0.9 5.3 0.7 2.8 1 5.3 0.4 2.4 0.9 5.3 0.4 300 17 301 255 0 0 0 0 19 0 19.4 18.8 04/30/2005 12:20:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 1.9 1.1 4.6 0.4 293 39 312 255 0 0 0 0 18.9 0.1 19.4 18.5 04/30/2005 12:30:00 2.7 0.7 4.2 0.7 2.4 0.6 4.2 0.4 2.3 0.8 4.2 0.4 324 24 285 255 0 0 0 0 19.2 0 20 19.1 04/30/2005 12:40:00 3.3 0.8 5.3 1.1 3.2 0.9 5.3 0.7 3 1.1 5.7 0.4 298 21 298 255 0 0 0 0 19.4 0 20 19.1 04/30/2005 12:50:00 2.7 0.8 4.6 0.4 2.6 0.9 4.6 0.4 2.3 0.9 4.6 0.4 294 24 293 255 0 0 0 0 19.4 0.1 20 19.1 04/30/2005 13:00:00 3.2 0.8 4.9 1.1 3.2 0.8 4.6 0.7 2.7 0.9 5.3 0.4 307 16 255 255 0 0 0 0 19.5 0 20 19.1 04/30/2005 13:10:00 3.3 1 5.7 1.1 3.2 1 5.7 0.7 2.9 1.2 5.7 0.4 304 16 305 255 0 0 0 0 19.5 0 20 19.1 04/30/2005 13:20:00 3.2 0.8 4.9 0.7 3.1 0.9 4.9 0.4 2.9 0.9 4.9 0.4 290 17 307 255 0 0 0 0 19.7 0.1 20 19.4 04/30/2005 13:30:00 2.7 1 4.9 0.4 2.6 0.9 4.6 0.4 2.3 1 4.6 0.4 297 38 339 255 0 0 0 0 20 0.3 20.5 19.4 04/30/2005 13:40:00 2.4 0.9 4.9 0.4 2.2 1 4.6 0.4 2.1 0.8 4.6 0.4 311 26 343 255 0 0 0 0 20.5 0 21.1 20.3 04/30/2005 13:50:00 2.5 1 4.6 0.4 2.4 1.1 4.6 0.4 2.1 1.1 4.6 0.4 295 33 264 255 0 0 0 0 20.8 0.1 21.1 20.5 04/30/2005 14:00:00 3.1 1.1 6.1 0.4 3 1.1 5.7 0.4 2.7 1.1 5.3 0.4 304 22 293 255 0 0 0 0 20.4 0 21.1 20.3 04/30/2005 14:10:00 3.2 1.3 5.7 0.4 3 1.3 5.7 0.4 2.8 1.2 5.7 0.4 315 19 311 255 0 0 0 0 20.2 0 20.5 20.3 04/30/2005 14:20:00 3.7 1 5.7 0.4 3.6 1.1 5.7 0.4 3.1 1.3 6.1 0.4 299 28 305 255 0 0 0 0 20.8 0.3 21.7 20.3 04/30/2005 14:30:00 3.2 1.2 6.1 0.7 3.2 1.2 5.7 0.4 2.8 1.2 5.7 0.4 282 18 295 255 0 0 0 0 21.1 0 21.4 20.8 04/30/2005 14:40:00 2.6 1.2 4.9 0.4 2.5 1.2 4.9 0.4 1.9 1.1 4.9 0.4 323 39 273 255 0 0 0 0 21.3 0.6 22.3 20.5 04/30/2005 14:50:00 2.2 1 4.6 0.4 2 1 4.6 0.4 1.7 1.1 4.6 0.4 305 36 291 255 0 0 0 0 23.1 0.3 23.5 22.3 04/30/2005 15:00:00 2.4 1.1 5.3 0.4 2.5 1.1 5.3 0.4 1.9 1.1 5.7 0.4 274 30 289 255 0 0 0 0 22.4 0.3 23.5 21.7 04/30/2005 15:10:00 2.4 1.2 4.9 0.4 2.2 1.2 4.9 0.4 1.9 1.2 4.6 0.4 312 22 311 255 0 0 0 0 22.4 0 22.6 22.3 04/30/2005 15:20:00 2.5 0.9 5.7 0.7 2.4 1 5.7 0.4 1.7 0.9 3.8 0.4 324 32 294 255 0 0 0 0 22.3 0 22.6 22 04/30/2005 15:30:00 2.9 1.2 5.3 0.4 2.8 1.2 5.7 0.4 2.3 1.2 4.9 0.4 292 27 285 255 0 0 0 0 22.4 0 22.9 22 04/30/2005 15:40:00 2.8 1.1 5.3 0.4 2.6 1.2 5.3 0.4 2.3 1.1 4.9 0.4 315 28 323 255 0 0 0 0 22.3 0 22.6 22 04/30/2005 15:50:00 3.2 1.6 6.5 0.4 3.1 1.7 6.1 0.4 2.9 1.4 6.1 0.4 301 23 307 255 0 0 0 0 22.4 0.1 22.9 22 04/30/2005 16:00:00 3.7 1 6.1 1.1 3.6 1 5.7 1.1 3.1 1.2 6.1 0.4 302 20 314 255 0 0 0 0 21.7 0.1 22 21.1 04/30/2005 16:10:00 2.8 1.1 5.3 0.4 2.7 1.2 5.3 0.4 2 1.2 4.9 0.4 302 27 317 255 0 0 0 0 21.3 0 21.4 21.1 04/30/2005 16:20:00 2.9 1 5.3 0.4 2.7 1 4.9 0.4 2.2 1 4.2 0.4 313 32 340 255 0 0 0 0 21.5 0 21.7 21.1 04/30/2005 16:30:00 2.7 1.2 4.9 0.4 2.5 1.2 4.9 0.4 2.1 1.2 4.9 0.4 311 29 302 255 0 0 0 0 20.7 0.3 21.1 20 04/30/2005 16:40:00 2.4 0.9 4.2 0.7 2.4 0.9 4.2 0.4 1.7 1 3.8 0.4 290 24 313 255 0 0 0 0 20 0 20.3 19.7 04/30/2005 16:50:00 2.2 0.8 4.9 0.4 2.2 0.8 4.6 0.4 1.9 0.9 4.6 0.4 272 22 261 255 0 0 0 0 20.2 0 20.8 20 04/30/2005 17:00:00 2.3 0.8 4.2 0.4 2.2 0.8 3.8 0.4 1.7 1 4.2 0.4 267 19 262 255 0 0 0 0 19.7 0.2 20.3 19.4 04/30/2005 17:10:00 1.4 0.6 3.4 0.4 1.3 0.6 3 0.4 1 0.7 3 0.4 262 20 251 255 0 0 0 0 19.2 0 19.4 19.1 04/30/2005 17:20:00 1.3 0.6 3 0.4 1.1 0.7 2.6 0.4 0.9 0.6 3 0.4 312 20 300 255 0 0 0 0 19.5 0.2 20 19.1 04/30/2005 17:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 335 41 274 255 0 0 0 0 19.5 0.1 20 19.4 04/30/2005 17:40:00 2.3 0.5 3.4 0.7 2.2 0.6 3.4 0.4 1.7 0.6 3 0.4 293 12 291 255 0 0 0 0 19.2 0.1 20 18.8 04/30/2005 17:50:00 2 0.4 3 0.7 1.9 0.5 3 0.4 1.6 0.6 3 0.4 297 12 293 255 0 0 0 0 18.5 0.2 19.4 18.2 04/30/2005 18:00:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.3 0.7 3 0.4 307 17 307 255 0 0 0 0 18.2 0.1 18.8 17.7 04/30/2005 18:10:00 1.7 0.8 3 0.4 1.5 0.8 3 0.4 1.1 0.7 2.6 0.4 316 12 306 255 0 0 0 0 17.6 0.2 18.2 17.1 04/30/2005 18:20:00 1 0.4 1.9 0.4 0.7 0.3 1.9 0.4 0.4 0.2 1.5 0.4 341 6 342 255 0 0 0 0 17.1 0 17.1 16.8 04/30/2005 18:30:00 1.3 0.5 2.6 0.4 0.8 0.4 2.3 0.4 0.7 0.4 1.9 0.4 334 4 340 255 0 0 0 0 16.8 0 16.8 16.8 04/30/2005 18:40:00 1.9 0.4 3 0.7 1.5 0.5 3 0.4 1.1 0.6 2.6 0.4 343 12 355 255 0 0 0 0 16.8 0 16.8 16.8 04/30/2005 18:50:00 2.2 0.5 3 0.7 1.7 0.5 3 0.4 1.4 0.6 3 0.4 339 10 336 255 0 0 0 0 16.8 0 16.8 16.8 04/30/2005 19:00:00 2.2 0.8 4.2 0.4 1.9 0.9 4.2 0.4 1.4 0.9 3.8 0.4 330 15 340 255 0 0 0 0 16.5 0 16.8 16.3 04/30/2005 19:10:00 1.7 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1 0.7 3 0.4 322 22 293 255 0 0 0 0 16.1 0 16.6 16 04/30/2005 19:20:00 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 318 19 342 255 0 0 0 0 16.1 0 16.6 16 04/30/2005 19:30:00 2.5 0.6 4.2 1.1 2.2 0.7 4.2 0.7 1.6 0.8 4.2 0.4 337 17 315 255 0 0 0 0 16 0 16.6 15.7 04/30/2005 19:40:00 2.9 0.8 4.9 1.1 2.6 0.9 4.9 0.7 1.9 1 4.6 0.4 349 17 5 255 0 0 0 0 15.9 0 16.3 15.7 04/30/2005 19:50:00 2.9 0.6 4.2 1.5 2.7 0.7 4.2 1.1 1.7 0.6 3 0.4 15 13 28 255 0 0 0 0 15.9 0 16.6 15.7 04/30/2005 20:00:00 2.6 0.7 4.6 1.1 2.4 0.8 4.6 0.7 1.3 0.9 3.8 0.4 357 13 2 255 0 0 0 0 15.2 0.2 16 14.9 04/30/2005 20:10:00 2.8 0.7 4.6 1.1 2.6 0.8 4.6 0.7 1.1 0.7 3 0.4 8 14 4 255 0 0 0 0 14.6 0.1 15.2 14.4 04/30/2005 20:20:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 0.8 0.6 3.4 0.4 26 56 12 255 0 0 0 0 14.1 0.1 14.6 13.8 04/30/2005 20:30:00 3 0.6 4.9 1.9 2.9 0.6 5.3 1.5 1.8 1 4.6 0.4 7 15 35 255 0 0 0 0 13.7 0.2 14.4 13.3 04/30/2005 20:40:00 3.5 0.5 4.9 1.5 3.4 0.5 4.9 1.5 2.8 0.6 4.2 1.1 26 12 9 255 0 0 0 0 15.3 0.3 16 14.4 04/30/2005 20:50:00 1.2 0.6 3 0.4 1 0.6 3 0.4 0.6 0.4 2.3 0.4 59 21 44 255 0 0 0 0 14.3 0.7 15.7 13 04/30/2005 21:00:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.5 0.2 1.5 0.4 77 10 84 255 0 0 0 0 12.9 0.1 13.3 12.5 04/30/2005 21:10:00 1.7 0.7 3 0.4 1.6 0.7 3 0.4 1.3 0.8 2.6 0.4 128 14 137 255 0 0 0 0 12.1 0.2 12.7 11.7 04/30/2005 21:20:00 2.1 0.3 3 1.1 2 0.4 2.6 0.7 1.6 0.4 2.6 0.7 100 10 88 255 0 0 0 0 11.4 0.2 12.2 11.1 04/30/2005 21:30:00 2 0.4 3 1.1 1.9 0.4 3 0.7 1.3 0.4 2.3 0.4 81 8 80 255 0 0 0 0 11 0 11.4 10.9 04/30/2005 21:40:00 2 0.6 3 0.4 1.8 0.7 3 0.4 1.1 0.6 2.3 0.4 81 17 78 255 0 0 0 0 11.1 0 11.7 10.9 04/30/2005 21:50:00 1.9 0.6 3.4 0.4 1.7 0.6 3 0.4 0.8 0.6 2.6 0.4 90 14 79 255 0 0 0 0 10.9 0 11.7 10.9 04/30/2005 22:00:00 2.1 0.5 3 0.7 2 0.5 3.4 0.7 1.1 0.6 2.3 0.4 86 13 84 255 0 0 0 0 11.9 0.4 12.7 11.1 04/30/2005 22:10:00 2.1 0.6 3.4 0.7 2 0.6 3.4 0.4 1.3 0.6 2.6 0.4 73 10 66 255 0 0 0 0 12.3 0 12.7 12.2 04/30/2005 22:20:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.5 0.3 1.9 0.4 40 19 76 255 0 0 0 0 12.4 0 12.7 12.2 04/30/2005 22:30:00 2.7 1 5.3 0.4 2.6 1 5.3 0.4 1.7 0.9 4.2 0.4 37 12 31 255 0 0 0 0 11.9 0.1 12.2 11.7 04/30/2005 22:40:00 3.7 0.4 4.6 2.3 3.6 0.4 4.9 2.3 3.1 0.6 4.6 1.5 41 9 42 255 0 0 0 0 12.7 0.6 13.8 11.7 04/30/2005 22:50:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 1 0.7 3 0.4 47 13 32 255 0 0 0 0 12.9 0.6 13.5 11.7 04/30/2005 23:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.4 0.2 1.5 0.4 77 15 64 255 0 0 0 0 10.7 0.4 11.9 10.1 04/30/2005 23:10:00 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 64 21 40 255 0 0 0 0 10 0 10.3 9.8 04/30/2005 23:20:00 1.1 0.6 3 0.4 1 0.6 2.6 0.4 0.5 0.4 2.3 0.4 76 17 75 255 0 0 0 0 9.8 0 10.3 9.6 04/30/2005 23:30:00 3.2 1.7 6.5 0.4 3.1 1.7 6.5 0.4 2.2 1.3 5.3 0.4 30 22 6 255 0 0 0 0 9.9 0 10.1 9.6 04/30/2005 23:40:00 3.2 0.7 4.9 1.9 3.1 0.7 4.9 1.5 2.1 0.8 3.8 0.4 16 17 27 255 0 0 0 0 10.3 0.2 10.6 9.8 04/30/2005 23:50:00 2.7 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.8 0.7 3.8 0.4 21 12 0 255 0 0 0 0 10.9 0.3 11.4 10.6 05/01/2005 00:00:00 3.3 0.9 5.7 1.5 3.1 0.9 5.3 1.5 2.2 1 4.6 0.4 24 15 20 255 0 0 0 0 11.1 0 11.4 10.6 05/01/2005 00:10:00 2.3 0.8 3.8 0.4 2.2 0.8 3.8 0.4 1.3 0.8 3.4 0.4 23 16 25 255 0 0 0 0 10.6 0.3 11.1 10.3 05/01/2005 00:20:00 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 53 10 33 255 0 0 0 0 10 0 10.6 9.6 05/01/2005 00:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 26 16 21 255 0 0 0 0 9.6 0 9.8 9.3 05/01/2005 00:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 340 11 353 255 0 0 0 0 9.2 0 9.6 9 05/01/2005 00:50:00 1.9 0.4 3 0.7 1.8 0.5 3 0.4 1.1 0.4 2.3 0.4 257 27 234 255 0 0 0 0 9 0 9.6 9 05/01/2005 01:00:00 2.4 0.5 3.8 1.1 2.4 0.6 3.8 1.1 1.1 0.6 3 0.4 243 10 233 255 0 0 0 0 8.8 0.1 9 8.5 05/01/2005 01:10:00 2.2 0.5 3 0.7 2.1 0.5 3 0.7 1.2 0.5 2.3 0.4 227 15 212 255 0 0 0 0 8.4 0 9 8.3 05/01/2005 01:20:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 1.4 0.5 2.3 0.4 216 9 218 255 0 0 0 0 8.3 0 8.8 8 05/01/2005 01:30:00 2 0.5 3 1.1 2.4 0.3 3 1.5 1.5 0.4 2.6 0.4 179 14 214 255 0 0 0 0 8.1 0 8.3 7.8 05/01/2005 01:40:00 1.6 0.4 2.6 0.4 1.9 0.5 3 0.4 1.2 0.5 2.6 0.4 176 8 166 255 0 0 0 0 8.1 0 8.3 8 05/01/2005 01:50:00 1.8 0.4 3 0.7 2.3 0.4 3 1.1 1.5 0.4 2.6 0.4 177 8 189 255 0 0 0 0 8.3 0.1 8.5 8 05/01/2005 02:00:00 2.2 0.4 3 1.1 2.6 0.4 3.8 1.1 1.8 0.5 3 0.7 168 7 167 255 0 0 0 0 8.7 0 9 8.5 05/01/2005 02:10:00 1.7 0.4 3 0.7 2.3 0.4 3 1.1 1.4 0.5 2.6 0.4 174 6 171 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 02:20:00 1.2 0.6 2.3 0.4 1.3 0.7 3 0.4 0.8 0.5 2.3 0.4 143 35 168 255 0 0 0 0 8.8 0 9.3 8.8 05/01/2005 02:30:00 1.6 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.7 2.6 0.4 37 15 49 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 02:40:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.4 1.9 0.4 86 12 76 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 02:50:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.6 0.4 1.9 0.4 88 6 101 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 03:00:00 1.5 0.7 2.6 0.4 1.4 0.7 2.6 0.4 0.7 0.5 2.3 0.4 100 15 110 255 0 0 0 0 8.7 0 8.8 8.5 05/01/2005 03:10:00 2 0.6 3 0.4 1.8 0.6 3 0.4 1.4 0.5 2.6 0.4 124 9 131 255 0 0 0 0 8.5 0 8.8 8.5 05/01/2005 03:20:00 2.2 0.8 3.8 0.4 2.1 0.9 3.4 0.4 1.6 0.9 3.4 0.4 147 9 148 255 0 0 0 0 8.7 0 9 8.5 05/01/2005 03:30:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 130 2 131 255 0 0 0 0 8.7 0 9 8.5 05/01/2005 03:40:00 1.8 0.5 2.6 0.7 1.7 0.5 2.6 0.4 1.2 0.7 2.6 0.4 113 22 83 255 0 0 0 0 8.5 0 8.8 8.5 05/01/2005 03:50:00 2.4 0.2 3 1.5 2.3 0.2 3 1.5 1.6 0.3 2.6 0.7 112 7 112 255 0 0 0 0 8.5 0 8.8 8.5 05/01/2005 04:00:00 3.1 0.7 4.6 1.1 3.1 0.7 4.6 0.7 2.5 0.9 4.2 0.4 130 8 143 255 0 0 0 0 8.8 0.3 9 8.3 05/01/2005 04:10:00 2.1 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.4 0.6 2.6 0.4 120 12 122 255 0 0 0 0 8.8 0 9 8.8 05/01/2005 04:20:00 2.7 0.8 4.6 0.7 2.6 0.9 4.6 0.4 1.9 0.8 4.2 0.4 108 19 71 255 0 0 0 0 9.2 0.2 9.6 8.8 05/01/2005 04:30:00 2.3 0.8 4.9 0.7 2.2 0.8 5.3 0.7 1.6 0.8 4.6 0.4 89 22 86 255 0 0 0 0 9.9 0.1 10.1 9.6 05/01/2005 04:40:00 2.3 0.6 3.8 0.7 2.3 0.7 3.8 0.4 1.7 0.7 3.4 0.4 83 14 71 255 0 0 0 0 10.1 0.2 10.6 9.6 05/01/2005 04:50:00 2.3 0.6 3.4 0.7 2.3 0.6 3.4 0.4 1.7 0.7 3.4 0.4 80 13 86 255 0 0 0 0 10.5 0 10.6 10.6 05/01/2005 05:00:00 1.6 0.8 3.4 0.4 1.6 0.9 3.4 0.4 1.3 0.9 3.4 0.4 69 14 85 255 0 0 0 0 10.6 0 10.6 10.6 05/01/2005 05:10:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 75 18 72 255 0 0 0 0 10.5 0 10.6 10.3 05/01/2005 05:20:00 1.5 0.3 2.3 0.4 1.3 0.3 2.3 0.4 0.9 0.5 1.9 0.4 91 15 69 255 0 0 0 0 10.3 0.1 10.6 10.1 05/01/2005 05:30:00 1.6 0.4 2.6 0.7 1.4 0.5 2.3 0.4 0.9 0.4 1.9 0.4 98 7 92 255 0 0 0 0 10.2 0 10.3 10.1 05/01/2005 05:40:00 2.2 0.8 4.2 0.4 2.1 0.8 3.8 0.4 1.5 0.8 3.4 0.4 74 18 75 255 0 0 0 0 9.8 0.1 10.1 9.6 05/01/2005 05:50:00 1.5 0.7 2.6 0.4 1.4 0.6 2.6 0.4 1 0.6 2.6 0.4 310 94 68 255 0 0 0 0 9.7 0 9.8 9.6 05/01/2005 06:00:00 1.5 0.7 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 335 17 343 255 0 0 0 0 9.4 0 9.6 9.3 05/01/2005 06:10:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.5 2.3 0.4 347 12 4 255 0 0 0 0 9 0 9.3 9 05/01/2005 06:20:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 341 14 336 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 06:30:00 1.5 0.5 3 0.4 1.1 0.5 2.6 0.4 0.7 0.4 1.5 0.4 337 12 330 255 0 0 0 0 8.6 0 8.8 8.5 05/01/2005 06:40:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 342 13 10 255 0 0 0 0 8.5 0 8.8 8.5 05/01/2005 06:50:00 1.5 0.7 3 0.4 1.3 0.8 3.4 0.4 0.8 0.7 3 0.4 3 11 26 255 0 0 0 0 8.7 0 9 8.5 05/01/2005 07:00:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 359 11 3 255 0 0 0 0 9 0 9.3 8.8 05/01/2005 07:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 14 16 54 255 0 0 0 0 9.4 0 9.6 9 05/01/2005 07:20:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 87 23 43 255 0 0 0 0 9.6 0.1 9.8 9.6 05/01/2005 07:30:00 0.7 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 104 15 68 255 0 0 0 0 9.8 0 9.8 9.8 05/01/2005 07:40:00 1.2 0.9 3.4 0.4 1.1 0.8 3.4 0.4 0.8 0.5 2.6 0.4 74 38 46 255 0 0 0 0 10.1 0 10.3 9.8 05/01/2005 07:50:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 28 9 37 255 0 0 0 0 10.5 0 10.6 10.3 05/01/2005 08:00:00 1.5 1 3.8 0.4 1.4 1 3.8 0.4 1.1 0.9 3.8 0.4 64 17 47 255 0 0 0 0 10.7 0 11.1 10.6 05/01/2005 08:10:00 2.5 0.6 3.8 1.1 2.4 0.6 3.8 0.7 1.9 0.7 3.8 0.4 52 14 55 255 0 0 0 0 11.2 0 11.4 10.9 05/01/2005 08:20:00 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 41 15 15 255 0 0 0 0 11.7 0.1 11.9 11.4 05/01/2005 08:30:00 2.8 0.8 4.6 0.4 2.8 0.9 4.6 0.4 2.1 0.9 4.2 0.4 20 21 11 255 0 0 0 0 12.3 0.1 12.7 11.9 05/01/2005 08:40:00 2.1 0.9 3.8 0.4 1.9 1 3.8 0.4 1.6 1 3.4 0.4 18 22 24 255 0 0 0 0 12.9 0.1 13 12.5 05/01/2005 08:50:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 0.7 1.9 0.7 3.8 0.4 9 13 9 255 0 0 0 0 13.4 0.3 14.4 12.7 05/01/2005 09:00:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 1.3 0.7 3 0.4 2 11 3 255 0 0 0 0 13.7 0.2 14.6 13.3 05/01/2005 09:10:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 1.5 0.6 3.4 0.4 52 17 69 255 0 0 0 0 12.8 0.2 13.5 12.5 05/01/2005 09:20:00 1.8 0.6 3 0.4 1.7 0.7 3 0.4 1.5 0.7 2.6 0.4 46 20 42 255 0 0 0 0 12.3 0 12.7 12.2 05/01/2005 09:30:00 1.9 0.6 3.4 0.4 1.8 0.7 3 0.4 1.4 0.6 3 0.4 56 13 47 255 0 0 0 0 12.3 0 12.7 12.2 05/01/2005 09:40:00 1.1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 63 13 57 255 0 0 0 0 12.2 0.1 12.7 11.9 05/01/2005 09:50:00 1.3 0.7 3 0.4 1.2 0.7 3.4 0.4 1 0.6 2.6 0.4 72 21 60 255 0 0 0 0 12.1 0 12.5 11.9 05/01/2005 10:00:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 30 19 7 255 0 0 0 0 12.3 0.1 12.7 11.9 05/01/2005 10:10:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 30 13 16 255 0 0 0 0 12.6 0 13 12.5 05/01/2005 10:20:00 1.6 0.8 3.8 0.4 1.5 0.8 3.4 0.4 1.2 0.7 3 0.4 30 13 359 255 0 0 0 0 12.7 0 13 12.5 05/01/2005 10:30:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 31 22 21 255 0 0 0 0 12.9 0.1 13.3 12.7 05/01/2005 10:40:00 1.7 0.7 3 0.4 1.6 0.7 3 0.4 1.5 0.8 3 0.4 32 17 43 255 0 0 0 0 13.3 0 13.8 13 05/01/2005 10:50:00 1.9 1 4.6 0.4 1.9 1.1 4.6 0.4 1.5 1 3.8 0.4 33 36 38 255 0 0 0 0 13.7 0 14.4 13.3 05/01/2005 11:00:00 2.8 0.7 4.6 1.1 2.7 0.7 4.6 1.1 2.2 0.8 3.8 0.4 28 23 42 255 0 0 0 0 13.8 0.1 14.4 13.5 05/01/2005 11:10:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1.1 0.7 3 0.4 48 28 38 255 0 0 0 0 14 0.1 14.6 13.8 05/01/2005 11:20:00 1.4 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1.1 0.7 3 0.4 12 23 349 255 0 0 0 0 14.2 0.1 14.9 13.8 05/01/2005 11:30:00 2.4 1 4.9 0.4 2.3 1 4.6 0.4 1.9 0.9 3.8 0.4 29 22 15 255 0 0 0 0 14.6 0 15.2 14.4 05/01/2005 11:40:00 2.7 1.1 4.9 0.4 2.5 1 5.3 0.4 2 1.2 4.9 0.4 334 24 358 255 0 0 0 0 14.6 0 15.2 14.4 05/01/2005 11:50:00 2.1 0.9 4.2 0.4 1.8 0.9 4.6 0.4 1.5 0.9 4.2 0.4 332 33 341 255 0 0 0 0 14.8 0.1 15.5 14.6 05/01/2005 12:00:00 1.8 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.5 0.7 2.6 0.4 22 30 347 255 0 0 0 0 14.9 0 15.5 14.6 05/01/2005 12:10:00 2.9 1 5.3 0.4 2.8 1.1 5.3 0.4 2.3 1 4.6 0.4 6 17 4 255 0 0 0 0 15.1 0.1 15.5 14.9 05/01/2005 12:20:00 2.1 0.8 3.8 0.4 2 0.8 4.2 0.4 1.8 0.7 3.8 0.4 301 23 296 255 0 0 0 0 15 0 15.5 14.6 05/01/2005 12:30:00 2.3 0.8 3.8 0.4 2.1 0.9 3.8 0.4 2 1 4.2 0.4 284 22 287 255 0 0 0 0 14.5 0.1 15.2 14.1 05/01/2005 12:40:00 1.9 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.4 0.9 3.4 0.4 279 35 255 255 0 0 0 0 14.6 0 14.9 14.4 05/01/2005 12:50:00 2.7 0.9 4.6 0.7 2.6 0.9 4.6 0.4 2.2 1 4.2 0.4 289 19 244 255 0 0 0 0 14.8 0.1 15.2 14.6 05/01/2005 13:00:00 2.8 1.2 5.3 0.4 2.7 1.2 5.3 0.4 2.2 1.3 5.3 0.4 286 23 256 255 0 0 0 0 14.2 0.2 14.9 13.8 05/01/2005 13:10:00 3.5 1 5.7 0.7 3.4 1.2 5.3 0.4 2.8 1 4.6 0.4 273 21 258 255 0 0 0 0 14 0 14.6 13.8 05/01/2005 13:20:00 3.4 0.8 5.3 1.5 3.3 0.8 5.3 1.1 2.9 0.9 4.9 1.1 287 17 289 255 0 0 0 0 13.5 0.3 14.1 12.7 05/01/2005 13:30:00 3 0.8 4.9 0.7 2.8 0.8 5.3 0.7 2.2 0.8 4.9 0.4 285 17 255 255 0 0 0 0 12.5 0.4 13.3 11.7 05/01/2005 13:40:00 4.7 1 6.8 2.3 4.5 0.9 6.8 2.3 3.5 1 6.1 1.5 288 13 270 255 0 0 0 0 11.2 0.3 11.9 10.6 05/01/2005 13:50:00 5.1 0.7 6.8 3.4 5 0.7 7.2 3.4 4 0.8 6.1 1.9 292 8 315 255 0 0 0 0 10.2 0.3 11.1 9.6 05/01/2005 14:00:00 2.4 1 4.6 0.7 2.1 1.1 4.2 0.4 1.4 1 4.2 0.4 319 15 294 255 0 0 0 0 9.6 0 10.3 9.6 05/01/2005 14:10:00 2.2 0.5 3 1.1 2.1 0.6 3 0.7 1.4 0.7 2.6 0.4 264 26 247 255 0 0 0 0 9.8 0 10.3 9.6 05/01/2005 14:20:00 1.7 0.7 3.4 0.4 1.5 0.7 3 0.4 1.1 0.7 2.6 0.4 284 35 244 255 0 0 0 0 10.1 0 10.6 9.8 05/01/2005 14:30:00 1.9 0.4 3 1.1 1.8 0.4 3 1.1 1.4 0.4 2.3 0.4 304 11 307 255 0 0 0 0 10.2 0 10.6 10.1 05/01/2005 14:40:00 2.8 0.6 4.6 1.1 2.4 0.7 4.2 0.7 1.8 0.7 3.8 0.4 336 12 333 255 0 0 0 0 10.2 0 10.6 10.1 05/01/2005 14:50:00 2.6 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.4 0.7 3.4 0.4 6 13 349 255 0 0 0 0 10 0 10.6 9.8 05/01/2005 15:00:00 2.7 0.4 4.2 1.9 2.6 0.5 3.8 1.5 2 0.7 3.4 0.4 22 11 23 255 0 0 0 0 10 0 10.3 9.8 05/01/2005 15:10:00 3 0.6 5.3 1.5 2.9 0.6 4.9 1.1 2.3 0.7 4.2 0.4 31 11 30 255 0 0 0 0 9.7 0 10.1 9.6 05/01/2005 15:20:00 3 1 5.3 0.7 2.9 1 5.3 0.7 2.2 0.8 4.6 0.4 37 21 24 255 0 0 0 0 9.6 0 9.8 9.3 05/01/2005 15:30:00 2.6 0.8 4.2 0.7 2.5 0.9 4.2 0.4 1.7 0.9 3.4 0.4 41 13 39 255 0 0 0 0 9.2 0 9.6 9 05/01/2005 15:40:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.4 0.8 3.8 0.4 38 22 49 255 0 0 0 0 9 0 9.3 9 05/01/2005 15:50:00 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.9 2.8 0.7 4.6 1.5 71 8 77 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 16:00:00 4 0.4 5.3 3 4 0.4 4.9 3 3 0.5 4.2 1.5 66 11 33 255 0 0 0 0 9 0 9.3 9 05/01/2005 16:10:00 3.3 0.7 4.9 1.5 3.2 0.7 4.6 1.1 2.2 0.7 3.8 0.7 50 11 46 255 0 0 0 0 9.1 0 9.3 9 05/01/2005 16:20:00 1.2 0.7 2.6 0.4 1.2 0.7 2.6 0.4 0.7 0.5 2.3 0.4 251 90 255 255 0 0 0 0 9.2 0 9.3 9 05/01/2005 16:30:00 1.6 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.2 0.8 3.8 0.4 245 13 254 255 0 0 0 0 9.1 0 9.3 9 05/01/2005 16:40:00 0.5 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 197 49 166 255 0 0 0 0 9.2 0 9.3 9 05/01/2005 16:50:00 2.9 0.9 4.6 0.4 3 0.7 4.2 0.4 2 0.9 3.4 0.4 193 11 184 255 0 0 0 0 9.2 0 9.3 9 05/01/2005 17:00:00 1.9 0.7 3.4 0.4 2 0.7 3.4 0.4 1.1 0.6 2.6 0.4 190 23 201 255 0 0 0 0 9.4 0 9.6 9.3 05/01/2005 17:10:00 1.8 0.7 3.8 0.4 1.7 0.6 3.4 0.4 1.1 0.6 3 0.4 81 12 93 255 0 0 0 0 9.6 0 9.6 9.6 05/01/2005 17:20:00 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 0.8 0.6 2.3 0.4 126 33 88 255 0 0 0 0 9.6 0 9.8 9.6 05/01/2005 17:30:00 1.4 0.8 3 0.4 1.5 0.9 3 0.4 1 0.6 2.3 0.4 183 17 192 255 0 0 0 0 9.6 0 9.6 9.6 05/01/2005 17:40:00 0.6 0.4 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 125 11 119 255 0 0 0 0 9.6 0 9.6 9.6 05/01/2005 17:50:00 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 211 16 243 255 0 0 0 0 9.5 0 9.6 9.6 05/01/2005 18:00:00 1.7 0.9 3 0.4 1.8 0.9 3 0.4 1.2 0.8 2.6 0.4 230 8 226 255 0 0 0 0 9.5 0 9.6 9.6 05/01/2005 18:10:00 2.5 0.5 4.2 1.1 2.6 0.5 3.8 1.5 1.8 0.6 3.4 0.4 243 11 229 255 0 0 0 0 9.5 0 9.6 9.6 05/01/2005 18:20:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.9 0.5 1.9 0.4 242 13 248 255 0 0 0 0 9.5 0 9.6 9.6 05/01/2005 18:30:00 2.1 0.5 3 0.7 2.1 0.5 3 0.4 1.2 0.5 2.6 0.4 221 9 228 255 0 0 0 0 9.5 0 9.6 9.6 05/01/2005 18:40:00 2.1 0.5 3.4 0.7 2.1 0.5 3 0.7 1.2 0.5 2.6 0.4 201 10 209 255 0 0 0 0 9.4 0 9.6 9.3 05/01/2005 18:50:00 1.1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 195 20 190 255 0 0 0 0 9.4 0 9.6 9.3 05/01/2005 19:00:00 1.7 0.5 3.4 0.4 2 0.5 3.4 0.7 1.4 0.6 2.6 0.4 182 9 196 255 0 0 0 0 9.2 0 9.6 9 05/01/2005 19:10:00 1.8 0.5 3.4 0.4 2.1 0.6 3.4 0.4 1.3 0.7 3 0.4 179 13 190 255 0 0 0 0 9 0 9.3 9 05/01/2005 19:20:00 1.8 0.6 3 0.4 1.9 0.6 3 0.4 1.2 0.6 2.6 0.4 172 14 179 255 0 0 0 0 8.9 0 9 8.8 05/01/2005 19:30:00 1.7 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1.2 0.5 2.6 0.4 165 11 168 255 0 0 0 0 8.8 0 9 8.8 05/01/2005 19:40:00 2 0.5 3.4 0.7 2.3 0.5 3.4 0.7 1.5 0.6 3 0.4 171 9 143 255 0 0 0 0 8.7 0 8.8 8.5 05/01/2005 19:50:00 2 0.5 3 0.4 1.9 0.5 3 0.4 1.3 0.6 2.6 0.4 160 9 155 255 0 0 0 0 8.5 0 8.8 8.5 05/01/2005 20:00:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 2.2 0.6 3.4 0.4 145 7 144 255 0 0 0 0 8.4 0 8.8 8.5 05/01/2005 20:10:00 2.7 0.6 4.2 1.1 2.7 0.5 4.2 1.1 1.9 0.6 3.4 0.4 152 15 144 255 0 0 0 0 8.4 0 8.5 8.5 05/01/2005 20:20:00 1.9 0.8 3.4 0.4 2 1 3.8 0.4 1.3 0.8 3.4 0.4 164 18 165 255 0 0 0 0 8.3 0 8.5 8.3 05/01/2005 20:30:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.5 0.4 120 22 146 255 0 0 0 0 8.1 0 8.3 7.8 05/01/2005 20:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 15 63 255 0 0 0 0 7.6 0.2 7.8 7.3 05/01/2005 20:50:00 1.3 0.5 1.9 0.4 1 0.6 1.9 0.4 0.6 0.4 1.9 0.4 70 12 63 255 0 0 0 0 7.1 0.1 7.3 6.7 05/01/2005 21:00:00 1.3 0.2 1.9 0.7 1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 109 5 110 255 0 0 0 0 6.6 0.1 7 6.2 05/01/2005 21:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 56 22 92 255 0 0 0 0 6.1 0 6.5 6 05/01/2005 21:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.4 1.9 0.4 62 53 333 255 0 0 0 0 5.7 0 6 5.7 05/01/2005 21:30:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.5 2.3 0.4 130 43 155 255 0 0 0 0 5.3 0.2 5.7 5 05/01/2005 21:40:00 1.8 0.7 3 0.4 1.7 0.8 3 0.4 1 0.8 3 0.4 123 15 133 255 0 0 0 0 5 0.1 5.2 4.8 05/01/2005 21:50:00 2.5 0.4 3.8 1.1 2.5 0.4 3.8 1.1 1.5 0.5 2.6 0.4 121 9 115 255 0 0 0 0 4.6 0 4.8 4.5 05/01/2005 22:00:00 2.7 0.7 4.2 1.1 2.6 0.7 4.2 1.1 1.7 0.5 3 0.4 121 11 108 255 0 0 0 0 4.4 0 4.5 4.3 05/01/2005 22:10:00 3.1 0.6 4.9 1.5 2.9 0.6 4.6 1.1 1.9 0.4 3.4 0.7 117 11 118 255 0 0 0 0 4.2 0 4.5 4 05/01/2005 22:20:00 3.1 0.9 5.3 1.1 3 1 5.3 0.7 2.2 0.7 3.8 0.4 114 13 110 255 0 0 0 0 4.6 0.1 5 4.3 05/01/2005 22:30:00 4.6 0.8 6.1 1.9 4.5 0.8 6.1 1.5 3.3 0.8 5.3 0.7 108 11 112 255 0 0 0 0 5.2 0.1 5.7 5 05/01/2005 22:40:00 4.1 0.7 5.7 2.6 4 0.7 5.7 2.3 2.8 0.7 4.6 1.1 109 11 99 255 0 0 0 0 5.7 0 6 5.7 05/01/2005 22:50:00 3.5 0.8 5.7 1.5 3.5 0.9 5.3 1.1 2.6 0.6 4.2 1.1 120 13 104 255 0 0 0 0 5.7 0 6 5.7 05/01/2005 23:00:00 4.1 0.6 5.3 1.9 4.1 0.6 5.3 2.3 3.1 0.7 4.9 1.5 138 8 134 255 0 0 0 0 5.9 0.1 6 5.7 05/01/2005 23:10:00 4 0.6 5.3 2.3 4 0.6 5.3 2.3 3.2 0.6 4.9 1.5 130 12 124 255 0 0 0 0 5.8 0 6 5.7 05/01/2005 23:20:00 3.5 0.8 6.1 1.1 3.5 0.8 5.7 1.1 2.5 0.6 4.2 1.1 122 12 131 255 0 0 0 0 5.7 0 6 5.7 05/01/2005 23:30:00 3.7 0.8 5.3 1.5 3.6 0.8 5.3 0.7 2.4 0.6 4.6 1.1 113 14 108 255 0 0 0 0 5.7 0 6 5.5 05/01/2005 23:40:00 4.4 0.6 5.7 2.3 4.4 0.6 5.7 2.3 2.9 0.8 4.9 0.7 107 12 104 255 0 0 0 0 5.4 0 5.7 5 05/01/2005 23:50:00 4.7 0.6 6.1 2.3 4.6 0.6 5.7 2.6 3.4 0.7 4.9 1.1 107 10 107 255 0 0 0 0 5.3 0 5.5 5 05/02/2005 00:00:00 4.4 0.6 5.7 2.6 4.4 0.6 5.3 2.6 3.3 0.7 4.9 1.9 108 10 101 255 0 0 0 0 5.3 0.1 5.7 5 05/02/2005 00:10:00 4.3 0.7 6.5 2.6 4.3 0.7 6.1 2.6 3 0.7 4.9 1.1 112 11 127 255 0 0 0 0 5.3 0 5.7 5 05/02/2005 00:20:00 4.1 0.7 5.7 2.3 4 0.7 5.7 1.9 3.1 0.8 5.3 1.5 114 12 92 255 0 0 0 0 5.2 0 5.5 5 05/02/2005 00:30:00 4.3 0.7 5.7 2.3 4.2 0.7 5.7 1.9 2.9 0.7 4.6 1.1 118 13 121 255 0 0 0 0 5.1 0 5 5 05/02/2005 00:40:00 4.2 0.6 5.7 2.6 4.1 0.6 5.7 2.3 2.9 0.7 4.6 1.5 113 11 116 255 0 0 0 0 4.9 0.1 5.2 4.5 05/02/2005 00:50:00 4.6 0.6 6.1 2.6 4.6 0.6 6.5 2.6 3.3 0.7 4.9 1.1 110 9 115 255 0 0 0 0 4.5 0 4.8 4.3 05/02/2005 01:00:00 4.8 0.9 6.8 2.3 4.7 0.9 6.5 1.9 3.6 0.8 5.7 1.9 114 12 102 255 0 0 0 0 4.8 0 5 4.5 05/02/2005 01:10:00 4.5 1 6.5 2.3 4.5 1 6.5 1.9 3.5 1 5.7 1.5 114 15 110 255 0 0 0 0 5.1 0 5.2 4.8 05/02/2005 01:20:00 4.7 1 6.8 1.9 4.7 1 6.8 1.5 3.5 1 5.7 0.7 115 13 101 255 0 0 0 0 5.1 0 5.5 5 05/02/2005 01:30:00 4.8 0.8 6.8 2.6 4.7 0.9 7.2 2.6 3.8 0.9 5.7 1.5 110 13 116 255 0 0 0 0 5.1 0 5.2 4.8 05/02/2005 01:40:00 4.8 0.8 6.1 2.3 4.7 0.8 6.5 2.6 3.6 0.8 5.3 1.9 108 12 93 255 0 0 0 0 4.9 0 5.2 4.8 05/02/2005 01:50:00 4.7 0.7 6.5 2.3 4.6 0.7 6.5 2.3 3.5 0.7 5.3 1.9 111 11 123 255 0 0 0 0 4.9 0 5 4.8 05/02/2005 02:00:00 4.9 0.8 6.8 2.3 4.9 0.8 6.8 2.6 3.7 0.9 6.1 1.9 111 12 112 255 0 0 0 0 4.9 0 5 4.8 05/02/2005 02:10:00 4.6 0.9 6.5 2.6 4.5 0.9 6.5 2.6 3.5 1 6.1 1.1 109 12 129 255 0 0 0 0 4.9 0 5 4.8 05/02/2005 02:20:00 4.9 0.8 6.5 2.6 4.9 0.8 6.5 2.3 3.8 0.8 5.7 1.5 106 11 105 255 0 0 0 0 5 0 5 4.8 05/02/2005 02:30:00 4.7 0.8 6.5 2.6 4.7 0.7 6.5 2.3 3.5 0.9 5.7 1.5 109 11 113 255 0 0 0 0 4.8 0 5 4.8 05/02/2005 02:40:00 4.5 0.9 6.5 2.6 4.4 0.8 6.8 2.6 3.3 0.8 4.9 1.1 112 13 102 255 0 0 0 0 4.8 0 5 4.8 05/02/2005 02:50:00 4.3 0.9 6.1 2.3 4.2 0.9 6.5 1.9 3.2 0.9 5.7 1.1 114 12 124 255 0 0 0 0 4.8 0 5 4.8 05/02/2005 03:00:00 4.2 0.8 5.7 2.3 4 0.8 5.7 2.3 3.1 0.8 5.3 1.1 117 14 110 255 0 0 0 0 4.6 0 4.8 4.5 05/02/2005 03:10:00 4.1 0.8 6.1 1.9 4 0.8 6.1 1.9 2.9 0.8 4.9 1.1 114 13 125 255 0 0 0 0 4.3 0 4.5 4.3 05/02/2005 03:20:00 4.1 0.8 6.1 1.9 4 0.9 6.5 1.9 3 0.8 4.9 1.1 113 13 113 255 0 0 0 0 4.3 0 4.5 4.3 05/02/2005 03:30:00 4.2 0.7 6.1 1.9 4.1 0.7 5.7 1.9 3 0.8 4.9 1.1 112 14 127 255 0 0 0 0 4.4 0 4.5 4.3 05/02/2005 03:40:00 4.1 0.7 5.7 2.3 4 0.7 5.7 2.3 2.9 0.7 4.6 1.1 107 11 112 255 0 0 0 0 4.4 0 4.5 4.3 05/02/2005 03:50:00 4.1 0.7 5.7 1.5 4 0.7 5.7 1.5 2.7 0.8 4.6 0.7 112 13 113 255 0 0 0 0 4.2 0 4.5 4 05/02/2005 04:00:00 4.1 0.8 6.1 1.5 4 0.8 5.7 1.1 3 0.8 4.9 1.5 113 12 123 255 0 0 0 0 4.3 0 4.5 4 05/02/2005 04:10:00 4 0.9 6.1 1.5 4 0.9 6.1 1.5 2.8 0.9 5.3 0.7 115 13 127 255 0 0 0 0 4.1 0 4.5 4 05/02/2005 04:20:00 3.6 1 6.1 1.1 3.5 1 6.1 1.5 2.5 0.8 4.9 0.7 113 15 112 255 0 0 0 0 4.2 0 4.5 4 05/02/2005 04:30:00 3.2 0.8 5.7 0.7 3.2 0.8 5.7 0.7 2.4 0.7 4.2 0.7 120 14 118 255 0 0 0 0 4 0 4.5 3.8 05/02/2005 04:40:00 3 0.8 5.3 1.1 2.9 0.8 4.9 1.1 2.2 0.7 4.6 0.4 118 15 100 255 0 0 0 0 3.8 0.1 4 3.5 05/02/2005 04:50:00 3 0.6 4.6 1.1 2.9 0.6 4.6 1.5 1.9 0.7 3.4 0.4 104 12 110 255 0 0 0 0 3.6 0.1 4 3.5 05/02/2005 05:00:00 3.2 0.6 5.3 2.3 3.2 0.6 5.3 1.9 2.3 0.5 4.6 1.1 90 7 105 255 0 0 0 0 3.3 0.2 3.5 2.8 05/02/2005 05:10:00 3.8 0.7 5.3 1.5 3.7 0.7 5.3 1.5 2.7 0.8 4.6 1.1 108 13 83 255 0 0 0 0 3 0.1 3.5 2.8 05/02/2005 05:20:00 3.3 0.7 4.9 1.1 3.3 0.7 4.9 0.7 2.4 0.8 4.6 0.7 110 16 105 255 0 0 0 0 3.8 0.2 4.5 3.3 05/02/2005 05:30:00 3.3 0.8 4.9 1.1 3.2 0.8 4.9 1.1 2.4 0.7 4.2 0.7 112 15 97 255 0 0 0 0 4.4 0 4.8 4.3 05/02/2005 05:40:00 3.5 1 5.7 1.5 3.5 1 5.7 1.1 2.7 0.8 4.9 1.1 113 15 115 255 0 0 0 0 4.5 0 4.8 4.5 05/02/2005 05:50:00 3.8 0.9 6.1 1.9 3.7 0.9 6.1 1.1 2.9 0.9 5.7 1.1 115 16 148 255 0 0 0 0 4.9 0.2 5.5 4.5 05/02/2005 06:00:00 3.3 0.8 5.3 1.5 3.3 0.7 5.3 1.5 2.5 0.8 5.7 0.4 119 14 106 255 0 0 0 0 5.1 0 5.5 5 05/02/2005 06:10:00 3 0.8 4.9 0.7 2.9 0.8 4.9 0.7 2.1 0.7 4.2 0.4 112 18 102 255 0 0 0 0 5.6 0.2 6.2 5.2 05/02/2005 06:20:00 2.7 0.7 4.9 1.1 2.6 0.7 4.6 1.1 2 0.7 4.2 0.4 100 12 105 255 0 0 0 0 6.1 0 6.7 6 05/02/2005 06:30:00 2.4 0.6 4.2 0.7 2.3 0.6 4.2 0.7 1.9 0.6 3.8 0.4 108 11 106 255 0 0 0 0 6.2 0 6.5 6.2 05/02/2005 06:40:00 2.8 0.8 4.9 0.7 2.7 0.8 4.6 0.7 2.3 0.8 4.6 0.4 114 17 90 255 0 0 0 0 6.4 0.2 6.7 6 05/02/2005 06:50:00 3.2 0.9 5.3 1.1 3 1 5.3 0.7 2.9 0.9 4.9 0.4 110 14 99 255 0 0 0 0 7.1 0.1 7.3 6.7 05/02/2005 07:00:00 3.3 0.6 4.9 2.3 3.2 0.7 4.9 1.5 3 0.6 4.9 1.1 105 13 119 255 0 0 0 0 7.5 0.1 7.8 7.3 05/02/2005 07:10:00 2.5 0.6 3.8 0.4 2.4 0.6 3.8 0.7 2.2 0.5 3.4 1.1 95 10 103 255 0 0 0 0 8.1 0.1 8.5 7.8 05/02/2005 07:20:00 1.9 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.4 0.6 2.6 0.4 93 16 97 255 0 0 0 0 8.9 0.1 9.3 8.5 05/02/2005 07:30:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.6 0.7 3.4 0.4 101 14 89 255 0 0 0 0 9.1 0 9.3 9 05/02/2005 07:40:00 1.6 0.6 3.4 0.4 1.4 0.7 3 0.4 1.5 0.6 3.4 0.4 104 15 91 255 0 0 0 0 9.3 0 9.6 9 05/02/2005 07:50:00 1.8 0.7 3 0.4 1.7 0.7 3 0.4 1.5 0.8 3.4 0.4 94 15 87 255 0 0 0 0 9.7 0.2 10.3 9.6 05/02/2005 08:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 68 28 94 255 0 0 0 0 10.5 0.1 10.9 10.3 05/02/2005 08:10:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 64 17 32 255 0 0 0 0 10.8 0 10.9 10.6 05/02/2005 08:20:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 49 22 34 255 0 0 0 0 11.1 0 11.7 10.9 05/02/2005 08:30:00 1.4 0.5 3 0.4 1.2 0.5 3 0.4 1.2 0.5 2.3 0.4 33 17 32 255 0 0 0 0 11.5 0.2 12.2 11.1 05/02/2005 08:40:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 31 13 33 255 0 0 0 0 11.9 0 12.5 11.7 05/02/2005 08:50:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 23 14 3 255 0 0 0 0 12.3 0.2 13 11.9 05/02/2005 09:00:00 2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.7 0.6 3 0.4 20 18 10 255 0 0 0 0 12.6 0 13 12.5 05/02/2005 09:10:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.4 0.5 2.6 0.4 19 19 28 255 0 0 0 0 12.7 0 13.3 12.5 05/02/2005 09:20:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 15 13 12 255 0 0 0 0 12.7 0.2 13.3 12.2 05/02/2005 09:30:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 355 21 358 255 0 0 0 0 13.1 0.1 13.8 12.7 05/02/2005 09:40:00 1.9 0.6 3 0.4 1.7 0.7 3 0.4 1.5 0.6 2.6 0.4 5 17 12 255 0 0 0 0 13.6 0.1 14.4 13 05/02/2005 09:50:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.1 0.6 3.4 0.4 3 17 343 255 0 0 0 0 13.9 0.1 14.6 13.5 05/02/2005 10:00:00 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.6 0.4 357 18 8 255 0 0 0 0 14.1 0.1 14.6 13.8 05/02/2005 10:10:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 11 26 18 255 0 0 0 0 14.2 0.1 14.9 13.8 05/02/2005 10:20:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 2.3 0.4 298 56 296 255 0 0 0 0 14.4 0.1 15.2 14.1 05/02/2005 10:30:00 1.5 0.7 3 0.4 1.4 0.7 2.6 0.4 1.3 0.6 3 0.4 353 39 5 255 0 0 0 0 14.2 0.1 14.6 13.8 05/02/2005 10:40:00 1.3 0.6 3 0.4 1.1 0.6 2.6 0.4 1 0.6 2.3 0.4 317 27 320 255 0 0 0 0 14.4 0.2 14.9 13.8 05/02/2005 10:50:00 1.6 0.9 3.8 0.4 1.4 1 3.4 0.4 1.1 0.8 3.4 0.4 23 90 0 255 0 0 0 0 15.2 0 15.5 14.9 05/02/2005 11:00:00 1.5 0.7 3 0.4 1.3 0.7 3 0.4 1.3 0.6 2.6 0.4 351 19 344 255 0 0 0 0 15.5 0 15.7 15.2 05/02/2005 11:10:00 0.8 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.8 0.5 2.3 0.4 28 29 37 255 0 0 0 0 15.7 0 16 15.5 05/02/2005 11:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 310 28 271 255 0 0 0 0 16.3 0.2 16.8 15.7 05/02/2005 11:30:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 1.1 0.6 3 0.4 225 26 240 255 0 0 0 0 16.6 0.1 16.8 16.3 05/02/2005 11:40:00 2.1 0.6 3.4 0.4 2 0.6 4.2 0.4 1.7 0.7 3.4 0.4 248 38 245 255 0 0 0 0 16.8 0.4 17.7 16.3 05/02/2005 11:50:00 2.1 0.5 3.4 0.7 2 0.6 3.4 0.4 1.8 0.5 3 0.4 23 26 5 255 0 0 0 0 17.1 0.2 17.7 16.3 05/02/2005 12:00:00 1.7 1 3.8 0.4 1.7 1 3.8 0.4 1.7 0.9 4.2 0.4 79 36 50 255 0 0 0 0 16.5 0 16.8 16.3 05/02/2005 12:10:00 2.1 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.5 0.7 3.4 0.4 9 35 6 255 0 0 0 0 16.8 0.4 17.7 16.6 05/02/2005 12:20:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 302 79 51 255 0 0 0 0 17.5 0.2 18.2 17.1 05/02/2005 12:30:00 2.3 1 4.2 0.4 2.2 1 4.2 0.4 2 1 4.2 0.4 354 56 343 255 0 0 0 0 17.5 0.2 18.2 17.1 05/02/2005 12:40:00 1.8 0.7 3.8 0.4 1.5 0.7 3.8 0.4 1.5 0.7 3.4 0.4 332 32 335 255 0 0 0 0 17.8 0 18.2 17.4 05/02/2005 12:50:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.4 0.7 3.4 0.4 293 51 331 255 0 0 0 0 17.7 0 18.2 17.4 05/02/2005 13:00:00 2 0.8 4.2 0.4 1.8 0.9 4.6 0.4 1.8 0.8 3.8 0.4 20 22 321 255 0 0 0 0 17.6 0.1 18.2 17.1 05/02/2005 13:10:00 2.5 1 4.6 0.4 2.4 1 4.6 0.4 2.2 1 4.9 0.4 325 58 318 255 0 0 0 0 18.1 0.3 19.1 17.7 05/02/2005 13:20:00 1.9 1 4.2 0.4 1.7 1 4.2 0.4 1.5 1 3.8 0.4 334 38 298 255 0 0 0 0 17.9 0.2 18.5 17.4 05/02/2005 13:30:00 2.1 1.1 5.3 0.4 1.9 1.1 4.9 0.4 1.8 1 4.6 0.4 73 66 44 255 0 0 0 0 18 0.5 19.1 17.1 05/02/2005 13:40:00 2.4 1.1 5.3 0.4 2.2 0.9 5.3 0.4 2.1 1 4.9 0.4 9 45 338 255 0 0 0 0 18.3 0.3 19.1 17.4 05/02/2005 13:50:00 1.9 1 4.2 0.4 1.8 1 4.2 0.4 1.6 0.9 3.4 0.4 55 66 8 255 0 0 0 0 18.9 0.2 19.4 18.5 05/02/2005 14:00:00 2.5 0.8 4.6 0.4 2.4 0.8 4.2 0.4 2 0.9 3.8 0.4 31 43 79 255 0 0 0 0 18.8 0 19.1 18.5 05/02/2005 14:10:00 2.4 0.8 4.9 0.4 2.3 0.8 4.2 0.7 2 0.8 3.8 0.4 311 82 280 255 0 0 0 0 19 0 19.4 18.5 05/02/2005 14:20:00 2.5 0.8 4.6 0.4 2.3 0.8 4.2 0.4 2.1 0.9 3.8 0.4 297 28 324 255 0 0 0 0 19.5 0.4 20.3 18.5 05/02/2005 14:30:00 2.3 1.1 5.3 0.4 2.2 1.1 5.3 0.4 2 1 4.6 0.4 257 61 205 255 0 0 0 0 18.5 0.1 18.8 18.2 05/02/2005 14:40:00 2.9 1.2 6.8 0.7 2.7 1.2 6.8 0.4 2.5 1.4 6.5 0.4 309 36 290 255 0 0 0 0 18 0 18.2 17.7 05/02/2005 14:50:00 3.5 0.9 5.7 0.7 3.1 0.9 5.7 0.7 2.8 1 5.3 0.4 328 19 351 255 0 0 0 0 18.5 0.2 18.8 18 05/02/2005 15:00:00 2.6 1.3 5.3 0.4 2.5 1.3 5.3 0.4 2.1 1.2 5.3 0.4 310 36 288 255 0 0 0 0 19.1 0 19.4 18.8 05/02/2005 15:10:00 2.8 1.1 6.1 0.7 2.6 1.1 6.1 0.4 2.3 1.1 5.7 0.4 323 26 328 255 0 0 0 0 19.2 0 19.7 19.1 05/02/2005 15:20:00 3.5 1 5.7 1.1 3.2 1 5.7 0.7 3.2 1 5.7 0.7 325 19 287 255 0 0 0 0 18.6 0.2 19.1 18.5 05/02/2005 15:30:00 3.8 1 6.5 1.5 3.5 1 5.7 1.1 3.1 1 5.3 0.7 325 24 321 255 0 0 0 0 18.7 0.2 19.1 18.2 05/02/2005 15:40:00 4.1 1 6.8 1.5 4 1 6.8 1.1 3.2 1 5.3 0.7 297 28 306 255 0 0 0 0 19 0 19.4 18.8 05/02/2005 15:50:00 3.6 1.2 6.1 0.4 3.5 1.2 6.5 0.4 3 1.3 6.5 0.4 286 22 253 255 0 0 0 0 18.6 0 18.8 18.2 05/02/2005 16:00:00 3.2 0.9 5.3 0.4 2.9 0.9 5.3 0.4 2.2 0.9 4.6 0.4 329 20 343 255 0 0 0 0 18.7 0 18.8 18.2 05/02/2005 16:10:00 3.9 1 7.2 0.7 3.7 1 6.8 0.4 2.9 1.1 6.1 0.4 317 22 286 255 0 0 0 0 18.7 0.1 18.8 18.2 05/02/2005 16:20:00 4.1 0.8 6.5 1.9 4.1 0.8 6.5 1.9 3.7 1 6.8 1.1 291 17 325 255 0 0 0 0 17.7 0.2 18.2 17.1 05/02/2005 16:30:00 3.7 1.1 6.5 1.1 3.5 1.2 6.5 0.4 3.1 1.2 6.5 0.4 285 27 359 255 0 0 0 0 17.1 0 17.4 16.8 05/02/2005 16:40:00 3.6 1.2 6.1 0.4 3.5 1.3 6.1 0.4 3.3 1.3 6.1 0.7 275 26 263 255 0 0 0 0 17.3 0.1 17.7 16.8 05/02/2005 16:50:00 3.1 1 5.7 0.4 3 1 5.7 0.4 2.6 1 5.7 0.4 282 28 289 255 0 0 0 0 17 0.1 17.4 16.8 05/02/2005 17:00:00 3.6 0.8 5.3 1.1 3.5 0.8 5.3 1.1 2.9 1 5.7 0.4 299 19 306 255 0 0 0 0 17.1 0 17.4 16.8 05/02/2005 17:10:00 3.9 1.1 6.8 1.9 3.9 1.2 6.8 1.1 3.4 1.3 6.8 0.4 305 18 319 255 0 0 0 0 16.8 0 17.4 16.8 05/02/2005 17:20:00 3.2 1 6.1 1.1 3.1 1 6.1 0.7 2.6 1 5.3 0.4 284 23 290 255 0 0 0 0 16.6 0 16.8 16.6 05/02/2005 17:30:00 3.7 1.2 6.5 0.7 3.6 1.3 6.5 0.4 3.1 1.3 6.1 0.4 288 21 287 255 0 0 0 0 16.2 0.1 16.8 16.3 05/02/2005 17:40:00 3.5 0.8 5.3 0.4 3.3 0.9 4.9 1.1 2.8 1 4.6 0.4 299 20 281 255 0 0 0 0 16 0 16.3 16 05/02/2005 17:50:00 3.8 0.8 5.7 1.1 3.7 0.8 5.3 1.1 3.2 1 5.3 0.4 303 15 302 255 0 0 0 0 15.9 0 16 15.7 05/02/2005 18:00:00 3.5 0.9 6.5 1.5 3.4 0.9 6.5 1.1 2.9 1.1 6.1 0.4 297 15 293 255 0 0 0 0 15.7 0 15.7 15.5 05/02/2005 18:10:00 3.1 0.9 5.3 1.5 3 1 5.7 0.7 2.7 0.9 5.3 1.1 294 11 294 255 0 0 0 0 15.3 0 15.7 15.2 05/02/2005 18:20:00 2.9 0.8 4.6 0.4 2.8 0.9 4.6 0.4 2.4 0.8 4.2 0.4 297 14 280 255 0 0 0 0 15 0 15.5 14.9 05/02/2005 18:30:00 3.2 0.8 4.9 1.1 3.1 0.8 4.9 1.1 2.5 0.9 4.6 0.4 295 12 291 255 0 0 0 0 14.7 0.1 15.2 14.6 05/02/2005 18:40:00 2.9 0.8 5.3 1.1 2.8 0.8 5.3 0.7 2.2 0.8 4.6 0.4 296 15 286 255 0 0 0 0 14.5 0.1 14.9 14.4 05/02/2005 18:50:00 2.5 0.7 4.2 0.7 2.4 0.8 4.6 0.4 1.9 0.8 3.8 0.4 297 14 270 255 0 0 0 0 13.9 0.2 14.6 13.3 05/02/2005 19:00:00 2.8 0.6 4.2 1.5 2.7 0.6 4.2 1.1 2.2 0.7 3.8 0.4 303 12 288 255 0 0 0 0 13.7 0 14.1 13.5 05/02/2005 19:10:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.9 3.4 0.4 305 15 325 255 0 0 0 0 13.4 0.2 13.8 13 05/02/2005 19:20:00 2.5 0.8 4.2 0.7 2.3 0.9 4.2 0.4 1.7 0.9 3.4 0.4 308 16 297 255 0 0 0 0 13.1 0.1 13.5 12.7 05/02/2005 19:30:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.9 2.5 0.7 4.6 0.4 308 10 301 255 0 0 0 0 12.9 0.1 13.3 12.7 05/02/2005 19:40:00 2.6 0.7 4.2 0.7 2.4 0.7 4.2 0.4 1.8 0.7 3.4 0.4 310 11 329 255 0 0 0 0 12.5 0.2 13 12.2 05/02/2005 19:50:00 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 325 11 313 255 0 0 0 0 11.9 0.1 12.5 11.7 05/02/2005 20:00:00 2 0.4 3 1.1 1.5 0.5 2.6 0.4 1.1 0.5 3 0.4 331 9 323 255 0 0 0 0 11.2 0.2 11.9 10.9 05/02/2005 20:10:00 2 0.4 3 1.1 1.5 0.4 2.6 0.7 1.1 0.4 2.3 0.4 339 6 337 255 0 0 0 0 10.5 0.2 11.4 10.1 05/02/2005 20:20:00 2.1 0.3 2.6 1.5 1.9 0.4 2.6 1.1 1.2 0.5 2.6 0.4 0 10 345 255 0 0 0 0 9.8 0.2 10.6 9.6 05/02/2005 20:30:00 2.5 0.3 3 1.9 2.4 0.3 3 1.5 1.4 0.4 2.3 0.4 13 5 6 255 0 0 0 0 9.5 0 9.8 9.3 05/02/2005 20:40:00 2.8 0.6 4.2 1.5 2.7 0.6 4.2 1.1 1.7 0.7 3.4 0.4 25 10 39 255 0 0 0 0 9.2 0.1 9.6 9 05/02/2005 20:50:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.7 0.5 3 0.7 12 10 18 255 0 0 0 0 8.7 0.1 9.3 8.5 05/02/2005 21:00:00 2.8 0.5 4.2 1.5 2.7 0.5 3.8 1.1 1.8 0.6 3 0.7 18 9 25 255 0 0 0 0 8.6 0 9 8.5 05/02/2005 21:10:00 2.9 0.5 4.2 1.9 2.8 0.5 4.2 1.9 1.9 0.4 3 0.7 17 11 8 255 0 0 0 0 8.1 0.2 8.5 7.5 05/02/2005 21:20:00 3.3 0.6 4.6 1.9 3.2 0.6 4.2 1.5 2.2 0.6 3.8 1.1 16 8 20 255 0 0 0 0 7.4 0.1 7.8 7.3 05/02/2005 21:30:00 3.5 0.5 4.6 2.3 3.5 0.5 4.6 2.3 2.3 0.5 4.2 1.1 19 9 35 255 0 0 0 0 7.1 0.1 7.3 6.7 05/02/2005 21:40:00 3.3 0.4 4.6 2.3 3.2 0.4 4.6 2.3 2.6 0.5 4.2 1.5 28 7 28 255 0 0 0 0 6.9 0 7.5 6.7 05/02/2005 21:50:00 2.9 0.4 4.2 1.5 2.8 0.4 3.8 1.9 2 0.5 3 0.7 25 10 33 255 0 0 0 0 6.7 0.1 7.5 6.5 05/02/2005 22:00:00 3 0.5 4.6 1.9 2.8 0.5 4.6 1.5 2 0.6 3.8 0.4 20 8 16 255 0 0 0 0 6.3 0 6.5 6.2 05/02/2005 22:10:00 2.5 0.4 3.8 1.5 2.4 0.5 3.8 1.1 1.5 0.5 2.6 0.4 26 6 28 255 0 0 0 0 6.2 0 6.5 6 05/02/2005 22:20:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.6 0.3 1.9 0.4 50 14 55 255 0 0 0 0 6.2 0 6.7 6 05/02/2005 22:30:00 1.6 0.4 3 0.4 1.4 0.5 2.6 0.4 1.2 0.4 2.3 0.4 100 13 97 255 0 0 0 0 6.1 0 6.5 6 05/02/2005 22:40:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.1 1.9 0.4 2.6 0.7 80 12 50 255 0 0 0 0 6.1 0 6.5 5.7 05/02/2005 22:50:00 2.3 0.4 3.4 1.1 2.2 0.4 3.4 1.1 1.6 0.4 2.6 0.7 68 8 61 255 0 0 0 0 5.7 0.1 6 5.2 05/02/2005 23:00:00 2.6 0.4 3.4 1.9 2.5 0.4 3.4 1.5 1.8 0.4 2.6 0.7 82 7 87 255 0 0 0 0 5.4 0 6 5.2 05/02/2005 23:10:00 2.8 0.4 3.8 1.5 2.7 0.5 3.8 1.1 2 0.4 3 1.1 71 7 77 255 0 0 0 0 5.2 0 5.5 5 05/02/2005 23:20:00 2.3 0.5 3.8 1.1 2.2 0.5 3.8 0.7 1.4 0.4 3 0.4 64 10 56 255 0 0 0 0 5.1 0 5.5 5 05/02/2005 23:30:00 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.2 0.5 2.6 0.4 65 11 56 255 0 0 0 0 4.8 0.1 5 4.5 05/02/2005 23:40:00 2.1 0.5 3.8 0.7 2 0.6 3.8 0.4 1.5 0.6 3 0.4 61 9 56 255 0 0 0 0 5.3 0.2 5.7 5 05/02/2005 23:50:00 2.1 0.6 3.4 0.4 1.9 0.6 3 0.4 1.2 0.6 2.6 0.4 77 13 91 255 0 0 0 0 4.9 0 5 4.8 05/03/2005 00:00:00 2.3 0.4 3.4 1.5 2.2 0.4 3.4 1.1 1.4 0.5 2.6 0.4 84 11 60 255 0 0 0 0 4.6 0 5 4.5 05/03/2005 00:10:00 2 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.2 0.5 2.3 0.4 103 11 100 255 0 0 0 0 4.3 0 4.5 4 05/03/2005 00:20:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1 0.4 1.5 0.4 112 13 93 255 0 0 0 0 4.2 0 4.5 4 05/03/2005 00:30:00 1.6 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.7 0.4 2.3 0.4 90 15 106 255 0 0 0 0 4.1 0 4.3 3.8 05/03/2005 00:40:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.5 0.4 104 30 85 255 0 0 0 0 3.8 0 4 3.8 05/03/2005 00:50:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 102 22 69 255 0 0 0 0 3.6 0.1 3.8 3.5 05/03/2005 01:00:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 88 17 96 255 0 0 0 0 3.4 0 3.5 3.3 05/03/2005 01:10:00 1.7 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 140 13 144 255 0 0 0 0 3 0.2 3.5 2.8 05/03/2005 01:20:00 2 0.5 3 0.7 1.9 0.6 3 0.4 1.8 0.5 3 0.4 139 10 145 255 0 0 0 0 2.7 0 2.8 2.6 05/03/2005 01:30:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.3 0.4 3.4 1.1 127 11 142 255 0 0 0 0 2.7 0 2.8 2.6 05/03/2005 01:40:00 2.9 0.6 4.9 1.1 2.8 0.6 4.2 0.7 1.8 0.4 3 0.7 113 12 92 255 0 0 0 0 2.4 0 2.6 2.1 05/03/2005 01:50:00 2.6 0.6 4.2 1.5 2.4 0.6 3.8 1.1 1.9 0.5 3.4 0.4 115 11 109 255 0 0 0 0 2.3 0 2.6 2.3 05/03/2005 02:00:00 3.1 0.7 4.9 1.1 3 0.8 4.9 1.1 2.2 0.6 3.8 0.7 115 10 98 255 0 0 0 0 2.4 0 2.6 2.3 05/03/2005 02:10:00 2.5 0.9 4.6 0.7 2.4 1 4.6 0.4 2.1 0.7 4.2 0.7 126 13 127 255 0 0 0 0 2.9 0.3 3.3 2.3 05/03/2005 02:20:00 1.6 0.7 3.8 0.4 1.4 0.8 3.4 0.4 0.7 0.4 1.9 0.4 122 14 101 255 0 0 0 0 2.9 0.1 3.3 2.6 05/03/2005 02:30:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 1 0.4 1.9 0.4 154 11 152 255 0 0 0 0 2.4 0.1 2.8 2.3 05/03/2005 02:40:00 0.8 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 151 17 141 255 0 0 0 0 2 0.2 2.3 1.8 05/03/2005 02:50:00 2.4 0.6 3.4 0.7 2.3 0.7 3.4 0.4 2.3 0.5 3.4 1.1 138 8 148 255 0 0 0 0 1.7 0 1.8 1.4 05/03/2005 03:00:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.2 0.4 3.4 1.1 134 9 146 255 0 0 0 0 1.7 0 1.8 1.6 05/03/2005 03:10:00 2.6 0.5 3.8 1.5 2.5 0.5 3.4 1.1 1.8 0.4 3 0.7 122 10 110 255 0 0 0 0 1.9 0 2.3 1.8 05/03/2005 03:20:00 2.5 0.5 3.8 1.1 2.4 0.6 3.4 1.1 1.7 0.5 3.4 0.4 123 15 101 255 0 0 0 0 1.8 0 1.8 1.8 05/03/2005 03:30:00 2.6 0.6 4.6 1.1 2.5 0.6 4.2 0.7 1.8 0.5 3.4 0.7 121 12 134 255 0 0 0 0 2.3 0.1 2.8 1.8 05/03/2005 03:40:00 2.4 0.7 4.2 0.7 2.2 0.7 3.8 0.4 1.5 0.5 3.4 0.4 122 15 119 255 0 0 0 0 3.3 0.3 4 2.6 05/03/2005 03:50:00 2.4 0.5 3.8 0.7 2.2 0.6 3.4 0.7 1.3 0.5 2.6 0.4 120 11 114 255 0 0 0 0 3.8 0 4.3 3.5 05/03/2005 04:00:00 2.2 0.5 3.8 1.1 2 0.6 4.2 0.7 1.1 0.6 3 0.4 113 12 115 255 0 0 0 0 3.8 0.1 4.3 3.5 05/03/2005 04:10:00 1.8 0.5 2.6 0.7 1.5 0.5 2.6 0.4 0.9 0.4 1.9 0.4 121 10 121 255 0 0 0 0 3.3 0 3.8 3 05/03/2005 04:20:00 2 0.5 3 0.7 1.8 0.5 3 0.4 1.4 0.4 2.6 0.4 123 8 119 255 0 0 0 0 3.2 0 3.5 3 05/03/2005 04:30:00 2 0.5 3.4 0.4 1.9 0.5 3 0.4 1.5 0.5 3 0.4 124 12 108 255 0 0 0 0 3.3 0 3.5 3.3 05/03/2005 04:40:00 2.2 0.5 3.8 1.1 2 0.5 3.4 0.7 1.5 0.5 2.6 0.4 125 13 117 255 0 0 0 0 3.7 0.2 4 3.3 05/03/2005 04:50:00 1.4 0.6 2.6 0.4 1.2 0.6 3 0.4 0.7 0.4 1.9 0.4 121 14 111 255 0 0 0 0 4 0 4.3 3.8 05/03/2005 05:00:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.5 2.3 0.4 135 12 134 255 0 0 0 0 4.1 0.1 4.5 3.8 05/03/2005 05:10:00 2 0.5 3 0.7 1.9 0.6 3.4 0.4 1.5 0.6 3 0.4 135 12 140 255 0 0 0 0 4.5 0 4.8 4.5 05/03/2005 05:20:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 1.2 0.5 2.3 0.4 129 17 134 255 0 0 0 0 5.1 0.3 5.7 4.5 05/03/2005 05:30:00 3 0.8 4.6 1.1 2.8 0.8 4.6 1.1 2.2 0.7 3.8 0.4 117 10 127 255 0 0 0 0 5.4 0 5.7 5.5 05/03/2005 05:40:00 2.3 0.6 3.8 1.1 2.1 0.6 4.2 0.7 1.4 0.7 3.8 0.4 120 13 107 255 0 0 0 0 5.7 0.1 6 5.5 05/03/2005 05:50:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.8 0.5 2.3 0.4 143 22 118 255 0 0 0 0 6.4 0.3 6.7 6 05/03/2005 06:00:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 132 17 152 255 0 0 0 0 6.4 0.2 6.7 6.2 05/03/2005 06:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 111 3 102 255 0 0 0 0 5.8 0.2 6.2 5.7 05/03/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 0 0 0 0 5.4 0.2 5.7 5 05/03/2005 06:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 118 11 129 255 0 0 0 0 5 0 5.2 4.8 05/03/2005 06:40:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 145 3 142 255 0 0 0 0 4.8 0 5 4.8 05/03/2005 06:50:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 160 3 162 255 0 0 0 0 4.9 0 5 4.8 05/03/2005 07:00:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 153 6 162 255 0 0 0 0 5 0 5.2 4.8 05/03/2005 07:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 147 2 148 255 0 0 0 0 5.5 0.1 5.7 5.2 05/03/2005 07:20:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 139 9 144 255 0 0 0 0 6.2 0.2 6.7 5.7 05/03/2005 07:30:00 1.2 0.7 3 0.4 1.1 0.7 3.4 0.4 0.9 0.7 3 0.4 107 19 88 255 0 0 0 0 7.6 0.4 8.3 6.7 05/03/2005 07:40:00 1.9 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.7 0.5 3.4 0.4 98 13 117 255 0 0 0 0 8.1 0.1 8.5 8 05/03/2005 07:50:00 2.8 0.7 4.2 0.7 2.8 0.8 4.2 0.7 2.4 0.7 4.2 0.4 87 17 105 255 0 0 0 0 8.5 0.2 9.3 8.3 05/03/2005 08:00:00 2.4 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2 0.6 3.8 0.4 70 16 90 255 0 0 0 0 9.7 0.3 10.3 9.3 05/03/2005 08:10:00 1.4 0.5 3 0.4 1.3 0.6 3 0.4 1.5 0.5 2.6 0.4 74 13 90 255 0 0 0 0 10.4 0 10.6 10.3 05/03/2005 08:20:00 1.1 0.5 2.3 0.4 1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 46 32 25 255 0 0 0 0 10.8 0.1 11.4 10.6 05/03/2005 08:30:00 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 1 0.4 1.9 0.4 8 12 26 255 0 0 0 0 11.7 0.2 12.2 11.1 05/03/2005 08:40:00 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 7 12 2 255 0 0 0 0 12.3 0.2 12.7 11.9 05/03/2005 08:50:00 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 18 21 30 255 0 0 0 0 12.8 0 13.3 12.7 05/03/2005 09:00:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.7 0.5 2.3 0.4 24 27 36 255 0 0 0 0 13.2 0.2 13.8 12.7 05/03/2005 09:10:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 17 32 2 255 0 0 0 0 13.5 0 13.8 13.3 05/03/2005 09:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 2.3 0.4 42 51 43 255 0 0 0 0 13.9 0.1 14.6 13.5 05/03/2005 09:30:00 1.3 0.7 3.4 0.4 1.2 0.8 3.8 0.4 0.8 0.6 3 0.4 255 51 213 255 0 0 0 0 14.3 0.2 14.9 13.8 05/03/2005 09:40:00 1.9 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.5 0.9 3.8 0.4 301 28 302 255 0 0 0 0 14.1 0.2 14.6 13.8 05/03/2005 09:50:00 2.6 0.7 4.9 1.1 2.4 0.8 4.9 0.4 2.2 0.8 4.2 0.4 311 23 322 255 0 0 0 0 13.8 0 14.4 13.5 05/03/2005 10:00:00 2.3 0.6 3.8 0.7 2.1 0.6 3.8 0.4 1.8 0.6 3 0.4 323 30 14 255 0 0 0 0 14.3 0.2 14.9 13.8 05/03/2005 10:10:00 2.1 1 5.3 0.4 1.9 1 5.3 0.4 1.6 0.8 4.6 0.4 324 49 328 255 0 0 0 0 15.2 0.1 15.7 14.6 05/03/2005 10:20:00 1.9 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.5 0.7 3.4 0.4 308 58 256 255 0 0 0 0 15.2 0.2 15.7 14.6 05/03/2005 10:30:00 2.2 0.7 3.8 0.4 2 0.8 4.2 0.4 1.7 1 4.2 0.4 293 47 281 255 0 0 0 0 15.2 0.4 16 14.6 05/03/2005 10:40:00 1.8 0.8 4.2 0.4 1.6 0.9 4.2 0.4 1.4 0.9 3.8 0.4 274 66 244 255 0 0 0 0 15.6 0 16 15.5 05/03/2005 10:50:00 2.8 1 5.3 0.4 2.7 1 4.9 0.4 2.1 1.2 4.2 0.4 293 33 274 255 0 0 0 0 16.2 0 16.6 16 05/03/2005 11:00:00 3.6 1 5.7 0.7 3.4 1.1 6.1 0.7 2.8 1.2 5.3 0.4 316 17 287 255 0 0 0 0 15.7 0.1 16.3 15.5 05/03/2005 11:10:00 2.1 0.8 4.2 0.4 2 0.8 4.2 0.4 1.7 0.9 3.8 0.4 315 33 337 255 0 0 0 0 16.2 0.1 16.8 15.7 05/03/2005 11:20:00 2.8 1 6.8 0.7 2.7 1.1 6.5 0.4 2.2 1 4.6 0.4 281 26 271 255 0 0 0 0 16.1 0 16.8 16 05/03/2005 11:30:00 2.8 1 4.9 0.4 2.6 1 4.9 0.4 2.2 1 4.6 0.4 300 27 291 255 0 0 0 0 16.2 0.3 16.8 15.7 05/03/2005 11:40:00 2.7 1.1 4.9 0.4 2.5 1.2 4.9 0.4 2 1.2 4.9 0.4 306 26 323 255 0 0 0 0 16.4 0.1 16.8 16 05/03/2005 11:50:00 2.1 1.2 4.6 0.4 1.9 1.2 4.6 0.4 1.5 1.2 4.6 0.4 312 43 295 255 0 0 0 0 16.8 0.4 17.7 16.3 05/03/2005 12:00:00 2.4 1 4.6 0.4 2.3 1 4.6 0.4 1.9 1.1 4.2 0.4 308 56 277 255 0 0 0 0 17.1 0.1 17.7 16.8 05/03/2005 12:10:00 1.8 0.8 3.8 0.4 1.7 0.7 3.4 0.4 1.5 0.8 3.8 0.4 301 56 328 255 0 0 0 0 16.9 0.4 18 16.3 05/03/2005 12:20:00 3 0.8 4.9 0.7 2.8 0.9 4.9 0.7 2.2 1 4.9 0.4 305 30 328 255 0 0 0 0 17.1 0.2 17.7 16.6 05/03/2005 12:30:00 2.9 1.1 5.7 0.4 2.7 1.1 5.3 0.4 2.4 1.2 5.3 0.4 294 35 348 255 0 0 0 0 16.9 0.2 17.7 16.6 05/03/2005 12:40:00 3.9 1.1 6.1 1.1 3.8 1.1 5.7 1.1 3.4 1.3 6.1 0.7 306 29 287 255 0 0 0 0 16.1 0.6 17.1 15.2 05/03/2005 12:50:00 3 0.7 4.6 1.1 2.8 0.7 4.6 1.1 2.5 0.7 4.2 0.4 301 17 287 255 0 0 0 0 15.2 0.2 15.7 14.9 05/03/2005 13:00:00 3 0.8 4.9 0.7 2.9 0.8 4.6 0.7 2.6 0.8 4.6 0.7 293 15 282 255 0 0 0 0 14.4 0.3 15.2 14.1 05/03/2005 13:10:00 2.8 0.6 4.9 1.1 2.6 0.6 4.6 1.1 2.4 0.6 4.2 0.4 303 20 290 255 0 0 0 0 14.8 0.4 16 14.4 05/03/2005 13:20:00 2.6 0.6 4.6 1.1 2.4 0.6 3.8 0.7 2.1 0.8 4.2 0.4 280 24 276 255 0 0 0 0 15.5 0.3 16 14.9 05/03/2005 13:30:00 2.5 1 4.6 0.4 2.3 0.9 4.2 0.4 2.1 1 4.2 0.4 313 29 311 255 0 0 0 0 15 0 15.2 14.6 05/03/2005 13:40:00 1.9 1.1 4.6 0.4 1.8 1 4.6 0.4 1.4 1 3.8 0.4 354 66 352 255 0 0 0 0 14.8 0 15.2 14.6 05/03/2005 13:50:00 2.3 0.7 3.8 0.4 2.1 0.7 3.4 0.4 1.8 0.8 3.4 0.4 319 28 336 255 0 0 0 0 14.7 0 14.9 14.6 05/03/2005 14:00:00 2.1 0.9 5.7 0.4 1.8 0.8 4.9 0.4 1.3 0.8 4.6 0.4 333 27 345 255 0 0 0 0 14.9 0 15.2 14.6 05/03/2005 14:10:00 2.6 1 5.3 0.4 2.3 0.8 4.9 0.4 1.8 1 4.6 0.4 345 18 345 255 0 0 0 0 15.7 0.2 16.3 15.2 05/03/2005 14:20:00 2.8 0.7 4.6 1.5 2.6 0.7 4.6 1.1 2.1 0.9 4.2 0.4 338 27 326 255 0 0 0 0 17.1 0.3 17.7 16.3 05/03/2005 14:30:00 3.6 1.1 6.1 0.7 3.3 1 5.7 0.7 2.7 1.2 5.7 0.4 336 30 354 255 0 0 0 0 17.5 0.2 18.2 17.1 05/03/2005 14:40:00 3.8 1 5.7 1.1 3.6 1.1 5.7 0.7 2.8 1.2 5.3 0.4 355 24 327 255 0 0 0 0 18.2 0.6 19.1 17.4 05/03/2005 14:50:00 3.7 1.1 6.1 0.4 3.5 1.1 6.1 0.4 2.7 1.1 5.3 0.4 353 22 331 255 0 0 0 0 17.6 0.1 18 17.1 05/03/2005 15:00:00 3.7 1.2 6.8 0.4 3.7 1.2 6.1 0.4 3 1.2 5.7 0.4 19 15 14 255 0 0 0 0 17.3 0 17.7 16.8 05/03/2005 15:10:00 3.5 1 6.1 1.1 3.4 1 6.1 1.5 2.7 1.1 5.3 0.4 12 16 5 255 0 0 0 0 16.9 0 17.4 16.8 05/03/2005 15:20:00 4.6 0.8 7.2 2.3 4.4 0.8 7.2 1.9 3.4 1.1 5.7 0.4 358 19 355 255 0 0 0 0 18 0.7 19.1 16.8 05/03/2005 15:30:00 3.9 0.9 6.1 1.9 3.7 1 6.1 1.5 2.7 1.1 5.7 0.4 350 15 343 255 0 0 0 0 16.9 0.4 18.2 16.3 05/03/2005 15:40:00 2.7 0.8 4.9 1.1 2.6 0.8 4.9 1.1 2.1 0.8 4.6 0.4 40 33 12 255 0 0 0 0 16 0.2 16.8 15.2 05/03/2005 15:50:00 2 0.6 3.8 0.7 2 0.6 3.8 0.7 1.8 0.8 4.2 0.4 159 24 195 255 0 0 0 0 14.4 0.2 15.2 14.1 05/03/2005 16:00:00 3.1 1.3 7.2 0.4 3.3 1.5 6.8 0.4 2.6 1.5 6.1 0.4 175 27 200 255 0 0 0 0 14.3 0 14.6 14.1 05/03/2005 16:10:00 3.3 1.1 5.7 0.4 3.5 1.2 6.1 0.4 3.2 1.3 5.7 0.4 170 26 187 255 0 0 0 0 14.6 0 14.9 14.4 05/03/2005 16:20:00 2.4 0.8 4.6 0.4 2.4 0.9 4.6 0.4 2.2 0.8 4.6 0.4 146 24 208 255 0 0 0 0 14.5 0 14.6 14.4 05/03/2005 16:30:00 1.8 1 5.7 0.4 1.7 0.9 5.7 0.4 1.3 0.8 4.9 0.4 100 94 345 255 0 0 0 0 14.7 0.1 15.2 14.6 05/03/2005 16:40:00 3.6 1 7.2 1.1 3.6 1 7.2 1.1 2.6 0.9 5.7 0.4 5 14 0 255 0 0 0 0 15.5 0 16 15.2 05/03/2005 16:50:00 2.9 0.7 4.9 1.5 2.9 0.6 4.9 1.5 2.4 0.7 4.2 0.4 23 11 16 255 0 0 0 0 15.9 0 16.3 15.7 05/03/2005 17:00:00 3.6 1 5.3 1.1 3.5 1 5.3 1.1 2.7 1 5.7 0.4 15 17 20 255 0 0 0 0 16.1 0 16.6 16 05/03/2005 17:10:00 3.7 0.8 5.3 1.9 3.6 0.8 5.7 1.9 3.2 0.7 4.9 1.5 41 13 55 255 0 0 0 0 15.4 0.4 16.3 14.9 05/03/2005 17:20:00 3.8 1.8 8.4 1.1 3.8 1.8 8.4 1.1 3 1.7 7.6 0.4 56 35 34 255 0 0 0 0 14.4 0.4 15.2 13.8 05/03/2005 17:30:00 4.6 1.5 8.4 1.5 4.6 1.6 8.4 1.5 3.6 1.4 6.8 0.7 24 17 12 255 0 0 0 0 13.9 0.2 14.6 13.3 05/03/2005 17:40:00 6.5 1.1 9.1 3.4 6.5 1.1 9.1 3.4 4.7 1.3 8 1.9 10 15 19 255 0 0 0 0 13 0.2 13.8 12.7 05/03/2005 17:50:00 3.7 1.1 6.5 1.1 3.6 1.1 6.8 0.7 2.8 1.1 6.1 0.7 57 15 20 255 0 0 0 0 12.9 0.1 13.3 12.7 05/03/2005 18:00:00 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2.1 0.5 3.4 0.7 69 10 71 255 0 0 0 0 13.2 0.1 13.5 13 05/03/2005 18:10:00 2.6 0.4 3.4 1.5 2.5 0.5 3.4 1.1 1.8 0.6 3.8 0.4 51 19 46 255 0 0 0 0 13.4 0 13.8 13 05/03/2005 18:20:00 4.2 1.2 6.5 1.9 3.8 1 6.1 1.9 2.9 1.2 6.5 0.4 348 22 341 255 0 0 0 0 13.4 0.1 13.8 13 05/03/2005 18:30:00 4.3 0.9 7.2 2.6 4.3 0.9 7.6 2.3 3.3 1 6.8 1.1 11 16 351 255 0 0 0 0 13 0.2 13.3 12.7 05/03/2005 18:40:00 2.2 0.9 4.6 0.7 2.1 1 4.6 0.4 1.5 0.8 3.8 0.4 332 38 294 255 0 0 0 0 12.9 0.1 13.3 12.7 05/03/2005 18:50:00 3.2 1.2 7.2 0.7 3.2 1.2 7.2 0.7 2.4 1.2 7.2 0.4 272 22 259 255 0 0 0 0 13.2 0 13.5 12.7 05/03/2005 19:00:00 4 1.3 8 0.7 4 1.4 8.4 0.7 3.2 1.3 8.4 0.4 272 21 268 255 0 0 0 0 13.1 0.2 13.5 12.7 05/03/2005 19:10:00 3.2 1.4 7.6 0.4 3.2 1.5 8 0.4 2.5 1.4 7.6 0.4 271 29 263 255 0 0 0 0 12.7 0 13.3 12.5 05/03/2005 19:20:00 3.6 1 6.8 1.1 3.6 1 6.5 1.5 2.4 1.1 5.3 0.4 266 23 268 255 0 0 0 0 12.5 0 12.7 12.2 05/03/2005 19:30:00 2.4 1.3 6.8 0.4 2.3 1.4 7.2 0.4 1.6 1.1 5.7 0.4 255 21 283 255 0 0 0 0 12.3 0 12.7 12.2 05/03/2005 19:40:00 2.7 1 5.3 0.4 2.7 1 5.7 0.4 2 1 4.9 0.4 270 21 238 255 0 0 0 0 12.3 0 12.5 12.2 05/03/2005 19:50:00 1.7 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1 0.7 3.4 0.4 280 28 256 255 0 0 0 0 11.9 0.1 12.5 11.7 05/03/2005 20:00:00 1.3 0.5 3 0.4 1.2 0.5 3 0.4 0.6 0.4 2.3 0.4 310 28 295 255 0 0 0 0 11.5 0.1 12.2 11.1 05/03/2005 20:10:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 356 9 356 255 0 0 0 0 10.8 0.2 11.1 10.6 05/03/2005 20:20:00 1.5 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.5 0.3 1.5 0.4 352 9 7 255 0 0 0 0 10.1 0.1 10.6 9.8 05/03/2005 20:30:00 1 0.4 2.3 0.4 0.9 0.4 2.3 0.4 0.5 0.3 1.9 0.4 300 24 280 255 0 0 0 0 9.5 0 9.8 9.3 05/03/2005 20:40:00 0.7 0.4 1.9 0.4 0.8 0.4 2.3 0.4 0.4 0.1 0.7 0.4 264 4 266 255 0 0 0 0 8.9 0.1 9.3 8.8 05/03/2005 20:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 280 12 281 255 0 0 0 0 8.4 0 9 8.3 05/03/2005 21:00:00 1.2 0.3 1.9 0.4 1.2 0.2 1.9 0.4 0.4 0.2 1.5 0.4 293 7 280 255 0 0 0 0 7.9 0 8.3 7.8 05/03/2005 21:10:00 2.5 0.7 4.6 0.7 2.5 0.7 4.9 1.1 1.4 0.7 3.4 0.4 252 15 252 255 0 0 0 0 7.5 0.1 8.3 7.3 05/03/2005 21:20:00 2.4 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.3 0.5 2.6 0.4 261 17 255 255 0 0 0 0 7.3 0 7.5 7.3 05/03/2005 21:30:00 2.8 0.5 4.2 1.5 2.7 0.6 4.2 1.5 1.5 0.5 3.4 0.4 272 12 279 255 0 0 0 0 6.9 0.1 7.3 6.7 05/03/2005 21:40:00 2.8 0.5 3.8 1.5 2.8 0.5 3.8 1.5 1.5 0.6 3 0.4 247 11 264 255 0 0 0 0 6.9 0 7.3 6.7 05/03/2005 21:50:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 1.4 0.5 2.6 0.4 222 10 249 255 0 0 0 0 6.9 0 7.3 6.7 05/03/2005 22:00:00 1.7 0.8 3.4 0.4 1.7 0.8 3 0.4 1.1 0.5 2.3 0.4 232 41 201 255 0 0 0 0 6.7 0 7 6.5 05/03/2005 22:10:00 1 0.5 1.9 0.4 1 0.4 1.9 0.4 0.6 0.3 1.1 0.4 292 29 293 255 0 0 0 0 6.3 0.1 6.7 6 05/03/2005 22:20:00 0.9 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.4 0 0.7 0.4 359 10 19 255 0 0 0 0 5.8 0.1 6.2 5.5 05/03/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 0 0 0 0 5.5 0.1 6 5 05/03/2005 22:40:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 79 86 159 255 0 0 0 0 5.1 0 5.2 5 05/03/2005 22:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 173 0 174 255 0 0 0 0 4.8 0.2 5 4.5 05/03/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 28 255 255 0 0 0 0 4.4 0 4.5 4.3 05/03/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 255 255 0 0 0 0 4.3 0 4.5 4.3 05/03/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 255 255 0 0 0 0 4.1 0 4.3 4 05/03/2005 23:30:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 100 0 100 255 0 0 0 0 3.9 0 4 3.5 05/03/2005 23:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 100 0 100 255 0 0 0 0 3.6 0 3.8 3.5 05/03/2005 23:50:00 1.6 1.2 3.4 0.4 1.6 1.2 3.4 0.4 1.5 0.6 2.6 0.4 180 49 226 255 0 0 0 0 3.6 0 3.8 3.5 05/04/2005 00:00:00 0.9 0.8 2.6 0.4 0.9 0.8 2.6 0.4 0.5 0.3 1.9 0.4 213 3 220 255 0 0 0 0 3.5 0 4 3.3 05/04/2005 00:10:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 210 4 212 255 0 0 0 0 3.5 0 3.8 3.3 05/04/2005 00:20:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 196 2 197 255 0 0 0 0 3.6 0 3.8 3.5 05/04/2005 00:30:00 0.9 0.4 1.9 0.4 1.1 0.5 1.9 0.4 0.7 0.5 1.5 0.4 169 10 174 255 0 0 0 0 3.5 0 3.5 3.5 05/04/2005 00:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 152 6 255 255 0 0 0 0 3.6 0 3.8 3.5 05/04/2005 00:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.4 1.5 0.4 147 0 148 255 0 0 0 0 3.6 0 3.8 3.5 05/04/2005 01:00:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 146 5 144 255 0 0 0 0 3.5 0 3.8 3.5 05/04/2005 01:10:00 1.2 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 133 4 131 255 0 0 0 0 3.4 0 3.5 3.5 05/04/2005 01:20:00 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.7 0.8 0.5 1.9 0.4 133 8 136 255 0 0 0 0 3.5 0 3.5 3.3 05/04/2005 01:30:00 1.2 0.2 1.9 0.4 1.1 0.2 1.5 0.4 0.4 0.1 0.7 0.4 126 0 126 255 0 0 0 0 3.5 0 3.5 3.5 05/04/2005 01:40:00 1.3 0.5 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0.1 0.7 0.4 120 3 125 255 0 0 0 0 3.4 0 3.5 3.3 05/04/2005 01:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 125 7 132 255 0 0 0 0 3.2 0.1 3.5 2.8 05/04/2005 02:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 132 0 132 255 0 0 0 0 2.7 0 2.8 2.6 05/04/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 132 0 255 255 0 0 0 0 2.3 0 2.6 2.1 05/04/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 132 0 255 255 0 0 0 0 2 0.1 2.6 1.8 05/04/2005 02:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 132 0 255 255 0 0 0 0 1.8 0 2.3 1.6 05/04/2005 02:40:00 0.6 0.3 1.1 0.4 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 110 9 132 255 0 0 0 0 1.7 0 2.1 1.6 05/04/2005 02:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 130 13 137 255 0 0 0 0 1.7 0 1.8 1.6 05/04/2005 03:00:00 0.9 0.2 1.5 0.4 0.9 0.2 1.1 0.4 0.4 0.2 1.1 0.4 122 17 103 255 0 0 0 0 1.8 0 2.1 1.6 05/04/2005 03:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 103 0 103 255 0 0 0 0 1.8 0 2.3 1.6 05/04/2005 03:20:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 1.1 0.5 1.9 0.4 107 2 255 255 0 0 0 0 1.8 0 2.1 1.6 05/04/2005 03:30:00 0.8 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.8 0.5 1.9 0.4 108 0 108 255 0 0 0 0 1.8 0 2.1 1.8 05/04/2005 03:40:00 0.4 0.1 0.7 0.4 0.4 0.2 0.7 0.4 0.9 0.5 2.3 0.4 128 12 137 255 0 0 0 0 2 0 2.3 1.8 05/04/2005 03:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.8 0.3 2.3 0.7 140 2 141 255 0 0 0 0 2.2 0 2.6 1.8 05/04/2005 04:00:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.6 0.3 1.9 0.4 98 30 108 255 0 0 0 0 2.3 0 2.6 2.1 05/04/2005 04:10:00 1.1 0.8 3 0.4 1 0.7 2.6 0.4 1 0.4 1.9 0.4 126 5 121 255 0 0 0 0 2.4 0 2.6 2.3 05/04/2005 04:20:00 1 0.6 2.3 0.4 1 0.5 1.9 0.4 0.5 0.3 1.1 0.4 92 27 100 255 0 0 0 0 2.4 0 2.6 2.3 05/04/2005 04:30:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1 0.5 2.3 0.4 132 8 118 255 0 0 0 0 2.6 0 2.8 2.3 05/04/2005 04:40:00 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.6 0.3 1.5 0.4 142 0 142 255 0 0 0 0 2.6 0 2.8 2.6 05/04/2005 04:50:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 142 0 142 255 0 0 0 0 2.6 0 2.8 2.3 05/04/2005 05:00:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 177 17 187 255 0 0 0 0 2.7 0 2.8 2.6 05/04/2005 05:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 186 4 171 255 0 0 0 0 2.9 0 3 2.8 05/04/2005 05:20:00 0.9 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.5 1.9 0.4 155 8 158 255 0 0 0 0 2.9 0 3 2.8 05/04/2005 05:30:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 149 0 149 255 0 0 0 0 3 0 3.3 2.8 05/04/2005 05:40:00 0.5 0.3 1.1 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 99 17 149 255 0 0 0 0 3.3 0 3.5 3 05/04/2005 05:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 82 12 93 255 0 0 0 0 3.5 0 3.8 3.5 05/04/2005 06:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 69 0 69 255 0 0 0 0 4 0 4.3 3.8 05/04/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 87 20 255 255 0 0 0 0 4.4 0.1 4.8 4.3 05/04/2005 06:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 151 26 168 255 0 0 0 0 4.8 0 5 4.5 05/04/2005 06:30:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 170 4 168 255 0 0 0 0 5.1 0.1 5.5 4.8 05/04/2005 06:40:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 176 0 176 255 0 0 0 0 5.7 0.1 6 5.5 05/04/2005 06:50:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 176 0 176 255 0 0 0 0 6.2 0.2 6.7 5.7 05/04/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 176 0 255 255 0 0 0 0 7.1 0.2 7.3 6.7 05/04/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 227 86 255 255 0 0 0 0 7.8 0.3 8.5 7.3 05/04/2005 07:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1 3 1 255 0 0 0 0 8.1 0 8.5 8 05/04/2005 07:30:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 308 45 279 255 0 0 0 0 8.5 0.2 9 8.3 05/04/2005 07:40:00 0.7 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.6 0.4 1.9 0.4 251 32 244 255 0 0 0 0 9 0 9 9 05/04/2005 07:50:00 0.7 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.5 0.2 1.5 0.4 261 35 269 255 0 0 0 0 9 0 9 8.8 05/04/2005 08:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 261 35 315 255 0 0 0 0 8.9 0 9 8.8 05/04/2005 08:10:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 283 19 314 255 0 0 0 0 9.2 0 9.6 9 05/04/2005 08:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 268 36 257 255 0 0 0 0 9.6 0.1 10.1 9.3 05/04/2005 08:30:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 249 43 215 255 0 0 0 0 10 0.1 10.3 9.6 05/04/2005 08:40:00 1.2 0.8 3 0.4 1.1 0.8 3 0.4 0.9 0.7 2.6 0.4 301 22 303 255 0 0 0 0 9.6 0.1 9.8 9.6 05/04/2005 08:50:00 1.9 0.6 3 0.4 1.8 0.6 3 0.4 1.4 0.7 3 0.4 313 17 304 255 0 0 0 0 9.9 0 10.3 9.6 05/04/2005 09:00:00 1.4 0.7 3.4 0.4 1.4 0.7 3.4 0.4 0.9 0.6 2.6 0.4 267 51 214 255 0 0 0 0 10.5 0.2 10.9 10.1 05/04/2005 09:10:00 1.2 0.6 2.6 0.4 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 243 33 259 255 0 0 0 0 10.6 0 10.9 10.6 05/04/2005 09:20:00 1.4 0.6 3 0.4 1.3 0.6 3 0.4 0.9 0.5 2.3 0.4 245 23 286 255 0 0 0 0 10.7 0.2 11.1 10.3 05/04/2005 09:30:00 1.1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1 0.7 3 0.4 250 56 325 255 0 0 0 0 11 0.3 11.9 10.6 05/04/2005 09:40:00 2.3 0.5 3.8 1.1 2.2 0.5 3.8 0.7 1.9 0.6 3 0.4 313 15 328 255 0 0 0 0 11.7 0.1 11.9 11.1 05/04/2005 09:50:00 1.6 0.5 3.4 0.4 1.5 0.6 3.4 0.4 1 0.6 2.6 0.4 325 26 307 255 0 0 0 0 11.1 0 11.7 11.1 05/04/2005 10:00:00 1.5 0.6 3 0.4 1.4 0.5 3 0.4 1.1 0.6 2.6 0.4 304 17 327 255 0 0 0 0 10.9 0 11.4 10.9 05/04/2005 10:10:00 1.8 0.7 3.8 0.4 1.7 0.7 3.4 0.4 1.2 0.8 3.4 0.4 282 28 279 255 0 0 0 0 11.3 0 11.7 11.1 05/04/2005 10:20:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.1 0.5 2.6 0.4 297 32 303 255 0 0 0 0 11.8 0.2 12.5 11.4 05/04/2005 10:30:00 0.8 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.6 0.4 1.5 0.4 9 86 264 255 0 0 0 0 11.9 0.1 12.5 11.7 05/04/2005 10:40:00 1.7 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.3 0.8 3.8 0.4 286 33 300 255 0 0 0 0 11.9 0.2 12.7 11.7 05/04/2005 10:50:00 2.4 0.9 4.6 0.4 2.3 1 4.6 0.4 2 0.9 4.6 0.4 286 16 280 255 0 0 0 0 12.1 0.1 12.7 11.7 05/04/2005 11:00:00 2.3 0.7 4.2 0.4 2.2 0.8 4.2 0.4 1.9 0.8 3.4 0.4 286 27 280 255 0 0 0 0 11.7 0 12.2 11.4 05/04/2005 11:10:00 2.6 1 4.6 0.4 2.6 1 4.9 0.4 2.2 1.1 4.9 0.4 272 19 265 255 0 0 0 0 11.5 0.2 12.2 11.1 05/04/2005 11:20:00 1.6 0.6 3.4 0.4 1.4 0.6 3 0.4 1 0.6 2.6 0.4 294 23 308 255 0 0 0 0 11.3 0.1 11.7 11.1 05/04/2005 11:30:00 2 0.6 3.8 0.4 1.8 0.6 3.8 0.4 1.5 0.7 3 0.4 294 21 310 255 0 0 0 0 11.1 0.1 11.7 10.9 05/04/2005 11:40:00 1.7 1 4.2 0.4 1.5 1 3.8 0.4 1.3 0.9 3.4 0.4 305 18 309 255 0 0 0 0 10.7 0.1 11.4 10.6 05/04/2005 11:50:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 299 17 301 255 0 0 0 0 11.5 0.3 12.5 10.9 05/04/2005 12:00:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 27 32 27 255 0 0 0 0 11.7 0 12.2 11.4 05/04/2005 12:10:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 12 32 0 255 0 0 0 0 11.9 0.1 12.5 11.7 05/04/2005 12:20:00 2.2 1 4.6 0.4 2 1.1 4.9 0.4 1.4 1 3.8 0.4 317 35 287 255 0 0 0 0 12.4 0.1 12.7 12.2 05/04/2005 12:30:00 2.4 0.8 4.2 0.4 2.2 0.9 4.2 0.4 1.7 1 4.2 0.4 328 23 356 255 0 0 0 0 12.7 0.2 13.3 12.2 05/04/2005 12:40:00 2.6 0.8 4.9 0.7 2.3 0.7 3.8 0.4 2.1 0.9 4.2 0.4 327 16 333 255 0 0 0 0 12 0.2 12.5 11.7 05/04/2005 12:50:00 2.9 0.9 4.9 0.7 2.7 1 4.9 0.4 1.9 0.9 3.8 0.4 353 17 4 255 0 0 0 0 11.7 0 12.2 11.7 05/04/2005 13:00:00 4.8 0.9 6.5 2.3 4.7 0.9 6.5 2.3 3.6 1 6.1 1.1 2 11 354 255 0 0 0 0 11.3 0.3 12.2 10.9 05/04/2005 13:10:00 5.2 1 8 3.4 5.1 1 8 3.4 4.6 1.1 7.6 2.3 26 9 28 255 0 0 0 0 10.5 0 11.4 10.3 05/04/2005 13:20:00 3.7 0.6 4.9 1.9 3.6 0.6 4.9 1.5 3.1 0.8 4.9 1.1 34 10 28 255 0 0 0 0 10.5 0.1 11.1 10.3 05/04/2005 13:30:00 3.6 0.8 4.9 1.5 3.5 0.8 4.9 1.5 2.9 0.8 4.6 0.7 43 13 35 255 0 0 0 0 11.3 0 11.7 10.9 05/04/2005 13:40:00 1.5 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.8 3.4 0.4 46 17 50 255 0 0 0 0 11.7 0.1 11.9 11.4 05/04/2005 13:50:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.9 0.5 2.3 0.4 7 15 3 255 0 0 0 0 12.2 0 12.7 11.9 05/04/2005 14:00:00 1.1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.6 0.5 2.3 0.4 310 23 291 255 0 0 0 0 12.5 0.1 12.7 12.2 05/04/2005 14:10:00 2.2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.6 0.8 3.4 0.4 290 17 301 255 0 0 0 0 12.6 0.1 13 12.5 05/04/2005 14:20:00 2 0.9 4.2 0.4 2 1 4.2 0.4 1.6 1 4.2 0.4 267 29 228 255 0 0 0 0 13 0.1 13.3 12.7 05/04/2005 14:30:00 2 1 4.2 0.4 1.9 1 4.2 0.4 1.4 1 4.2 0.4 257 36 277 255 0 0 0 0 14.4 0.4 15.2 13.3 05/04/2005 14:40:00 2.5 1.1 4.2 0.4 2.4 1 4.6 0.4 2 1 4.2 0.4 241 58 303 255 0 0 0 0 14.4 0.3 15.5 13.8 05/04/2005 14:50:00 2.2 1.2 5.3 0.4 2 1.2 5.3 0.4 1.6 1 4.9 0.4 285 32 303 255 0 0 0 0 14 0.1 14.6 13.8 05/04/2005 15:00:00 3 1.2 4.9 0.4 3 1.2 5.3 0.4 2.3 1 4.6 0.4 264 22 267 255 0 0 0 0 13.5 0 14.1 13.3 05/04/2005 15:10:00 3.3 1 6.5 0.7 3.3 1 5.7 0.7 2.4 1 4.9 0.4 249 21 255 255 0 0 0 0 13.4 0 13.8 13.3 05/04/2005 15:20:00 3.1 1.5 6.1 0.4 3 1.5 6.5 0.4 2.4 1.5 5.7 0.4 260 35 252 255 0 0 0 0 13.1 0.3 13.8 12.7 05/04/2005 15:30:00 3.4 1.1 5.7 0.4 3.3 1.1 5.7 0.4 2.6 1 4.9 0.4 245 22 252 255 0 0 0 0 13 0.1 13.3 12.7 05/04/2005 15:40:00 3.3 1.3 6.1 0.4 3.3 1.3 6.1 0.7 2.4 1.3 6.1 0.4 244 26 262 255 0 0 0 0 12.5 0.2 13 11.9 05/04/2005 15:50:00 3.4 1.1 6.1 0.4 3.3 1.1 6.1 0.4 2.5 1.2 5.3 0.4 248 21 261 255 0 0 0 0 12.1 0.1 12.5 11.9 05/04/2005 16:00:00 2.9 1 5.7 0.4 2.8 1.1 5.3 0.4 2.1 1.1 5.7 0.4 246 30 252 255 0 0 0 0 11.8 0.1 12.2 11.7 05/04/2005 16:10:00 2.6 0.8 4.6 0.4 2.4 0.9 4.2 0.4 1.8 0.9 4.2 0.4 252 28 247 255 0 0 0 0 11.9 0.1 12.5 11.7 05/04/2005 16:20:00 2.2 1.2 4.9 0.4 2.1 1.2 4.6 0.4 1.6 1.2 4.2 0.4 253 51 267 255 0 0 0 0 12.1 0.1 12.5 11.9 05/04/2005 16:30:00 2.1 1.1 4.6 0.4 2 1.1 4.6 0.4 1.3 1 4.2 0.4 252 43 237 255 0 0 0 0 12.3 0 12.7 12.2 05/04/2005 16:40:00 1.7 0.8 4.2 0.4 1.6 0.9 4.2 0.4 1.2 0.9 3.8 0.4 278 35 240 255 0 0 0 0 12.5 0.3 13.3 12.2 05/04/2005 16:50:00 1.4 0.8 3 0.4 1.3 0.8 3 0.4 1 0.7 3 0.4 240 21 247 255 0 0 0 0 12.9 0.1 13.3 12.7 05/04/2005 17:00:00 1.4 0.7 3 0.4 1.4 0.8 3 0.4 1 0.7 2.6 0.4 228 29 252 255 0 0 0 0 13.4 0.2 14.1 13 05/04/2005 17:10:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 211 82 312 255 0 0 0 0 13.4 0.2 13.8 13 05/04/2005 17:20:00 1.5 0.8 3.4 0.4 1.3 0.8 3.8 0.4 0.8 0.6 2.6 0.4 278 38 312 255 0 0 0 0 13.1 0.1 13.5 12.7 05/04/2005 17:30:00 3.2 1.6 6.1 0.4 3.1 1.6 6.1 0.4 2.5 1.3 5.7 0.4 307 10 311 255 0 0 0 0 12.7 0.1 13.3 12.5 05/04/2005 17:40:00 3.4 1.1 6.1 1.5 3.3 1.2 6.1 1.1 2.8 1.1 6.1 0.4 269 22 276 255 0 0 0 0 12.1 0.2 12.7 11.9 05/04/2005 17:50:00 3.2 1.3 7.2 0.7 3.1 1.3 7.6 0.4 2.4 1.2 6.1 0.4 269 22 272 255 0 0 0 0 12.3 0 12.5 11.9 05/04/2005 18:00:00 1.9 1 3.8 0.4 1.8 1 3.8 0.4 1.2 0.9 3.4 0.4 266 33 266 255 0 0 0 0 11.7 0 12.2 11.7 05/04/2005 18:10:00 2.3 1.2 5.3 0.4 2.1 1.3 5.3 0.4 1.4 1.1 4.9 0.4 266 33 293 255 0 0 0 0 11.7 0 12.2 11.7 05/04/2005 18:20:00 3.6 0.7 4.9 1.1 3.5 0.7 4.9 1.1 2.8 0.8 4.6 0.7 279 17 286 255 0 0 0 0 11.7 0 11.7 11.7 05/04/2005 18:30:00 3.1 0.8 5.3 1.5 3 0.8 4.9 1.1 2.2 0.9 4.2 0.4 290 18 314 255 0 0 0 0 11.7 0 11.9 11.7 05/04/2005 18:40:00 2.8 0.9 4.9 0.7 2.6 0.9 4.9 0.4 2.1 1 4.6 0.4 291 17 281 255 0 0 0 0 11.9 0 12.2 11.7 05/04/2005 18:50:00 3.4 1 6.1 1.1 3.3 1 6.1 1.5 2.5 1.2 6.1 0.4 281 19 276 255 0 0 0 0 12.2 0 12.2 11.9 05/04/2005 19:00:00 3.3 1 5.3 0.4 3.3 1 4.9 0.4 2.5 1.2 5.3 0.4 265 19 283 255 0 0 0 0 12.3 0 12.5 11.9 05/04/2005 19:10:00 2.6 1 4.6 0.4 2.5 1.1 4.6 0.4 1.8 1.1 4.2 0.4 264 24 282 255 0 0 0 0 11.8 0.1 12.2 11.7 05/04/2005 19:20:00 2.5 0.8 4.9 0.7 2.3 0.9 4.6 0.4 1.7 1 4.2 0.4 260 20 253 255 0 0 0 0 11.3 0 11.7 11.1 05/04/2005 19:30:00 2.2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.4 0.8 3.8 0.4 262 16 267 255 0 0 0 0 10.9 0 11.1 10.6 05/04/2005 19:40:00 2.3 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.6 0.9 4.2 0.4 256 19 237 255 0 0 0 0 10.6 0 10.9 10.6 05/04/2005 19:50:00 2.7 0.6 4.6 0.7 2.7 0.6 4.2 0.7 1.9 0.7 4.2 0.4 246 12 237 255 0 0 0 0 10.6 0 11.1 10.6 05/04/2005 20:00:00 2 0.8 3.8 0.7 1.9 0.9 3.8 0.4 1.3 0.8 3.8 0.4 252 13 222 255 0 0 0 0 10.6 0 11.1 10.6 05/04/2005 20:10:00 2.4 0.8 4.9 0.4 2.3 0.9 4.6 0.4 1.5 0.8 4.2 0.4 256 19 265 255 0 0 0 0 10.6 0 10.6 10.6 05/04/2005 20:20:00 2 0.8 3.8 0.4 1.8 0.8 3.4 0.4 1.4 0.8 4.2 0.4 267 13 267 255 0 0 0 0 10.4 0.1 10.6 10.3 05/04/2005 20:30:00 2.1 0.7 3.8 0.4 2 0.8 3.8 0.4 1.5 0.8 3 0.4 274 12 259 255 0 0 0 0 10 0.1 10.3 9.6 05/04/2005 20:40:00 2.2 0.7 4.2 0.4 2.1 0.8 4.6 0.4 1.2 0.8 3 0.4 263 20 256 255 0 0 0 0 9.4 0.1 9.8 9 05/04/2005 20:50:00 1.6 0.7 3 0.4 1.4 0.6 3 0.4 0.7 0.5 2.6 0.4 264 13 281 255 0 0 0 0 8.6 0.2 9 8.3 05/04/2005 21:00:00 1.9 0.5 3.4 0.7 1.7 0.5 3.4 0.4 0.8 0.5 2.6 0.4 276 12 276 255 0 0 0 0 7.8 0.2 8.3 7.3 05/04/2005 21:10:00 2.3 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1 0.6 2.6 0.4 277 13 284 255 0 0 0 0 6.9 0.2 7.3 6.7 05/04/2005 21:20:00 3 0.7 4.6 1.1 2.9 0.7 4.6 1.1 1.8 1 4.6 0.4 266 17 277 255 0 0 0 0 6.7 0.1 7.3 6.5 05/04/2005 21:30:00 2.4 0.8 4.2 0.4 2.3 0.8 4.6 0.4 1.2 0.7 3.4 0.4 262 15 263 255 0 0 0 0 7 0 7.3 6.7 05/04/2005 21:40:00 2 0.5 3.4 0.7 1.8 0.5 3 0.7 0.8 0.5 2.3 0.4 265 11 255 255 0 0 0 0 6.4 0.2 6.7 6 05/04/2005 21:50:00 1.8 0.5 3 0.7 1.6 0.5 3 0.7 0.7 0.4 1.9 0.4 269 9 280 255 0 0 0 0 5.6 0.2 6 5.2 05/04/2005 22:00:00 2.1 0.5 3.4 0.7 2 0.5 3.8 0.7 0.9 0.5 2.6 0.4 268 10 253 255 0 0 0 0 5.1 0 5.2 5 05/04/2005 22:10:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 254 9 258 255 0 0 0 0 4.7 0.1 5 4.5 05/04/2005 22:20:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.1 1.1 0.4 261 6 261 255 0 0 0 0 4.3 0 4.5 4.3 05/04/2005 22:30:00 2.1 0.6 3.8 0.7 1.9 0.6 3.8 0.4 1 0.5 3 0.4 245 8 235 255 0 0 0 0 4.4 0 4.5 4.3 05/04/2005 22:40:00 0.7 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 268 6 269 255 0 0 0 0 4 0 4.3 3.8 05/04/2005 22:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 269 0 269 255 0 0 0 0 3.6 0 3.8 3.5 05/04/2005 23:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 269 0 269 255 0 0 0 0 3.3 0 3.5 3.3 05/04/2005 23:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 268 255 0 0 0 0 3.1 0 3.3 3 05/04/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 255 255 0 0 0 0 2.9 0 3.3 2.8 05/04/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 255 255 0 0 0 0 2.6 0.1 2.8 2.3 05/04/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 79 255 255 0 0 0 0 2.3 0 2.6 2.1 05/04/2005 23:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 78 0 78 255 0 0 0 0 2.1 0.1 2.3 1.8 05/05/2005 00:00:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 78 0 78 255 0 0 0 0 1.9 0 2.1 1.8 05/05/2005 00:10:00 1.3 0.3 1.9 0.7 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 68 3 67 255 0 0 0 0 1.7 0 1.8 1.6 05/05/2005 00:20:00 1.3 0.2 1.9 0.7 1.1 0.2 1.9 0.7 0.8 0.5 1.9 0.4 70 4 67 255 0 0 0 0 1.5 0.1 1.8 1.4 05/05/2005 00:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 76 0 76 255 0 0 0 0 1.3 0 1.6 1.1 05/05/2005 00:40:00 1.3 0.3 1.9 0.7 1.1 0.3 1.9 0.7 0.5 0.3 1.1 0.4 88 11 85 255 0 0 0 0 1 0.1 1.4 0.9 05/05/2005 00:50:00 1.5 0.3 1.9 0.7 1.3 0.3 1.9 0.4 0.4 0 0.4 0.4 85 6 88 255 0 0 0 0 0.9 0 1.1 0.7 05/05/2005 01:00:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 73 0 73 255 0 0 0 0 0.7 0 0.9 0.7 05/05/2005 01:10:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.6 2.3 0.4 103 30 140 255 0 0 0 0 0.7 0 0.9 0.7 05/05/2005 01:20:00 1.6 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.4 0.4 2.3 0.4 137 8 124 255 0 0 0 0 0.4 0.1 0.9 0.2 05/05/2005 01:30:00 2.1 0.4 3 1.5 2 0.4 3 1.1 1.5 0.5 3 0.7 135 6 124 255 0 0 0 0 0.2 0 0.7 -0.1 05/05/2005 01:40:00 1.9 0.8 3 0.4 1.8 0.8 3 0.4 1.2 0.8 3 0.4 125 6 107 255 0 0 0 0 -0.1 0 0.4 -0.3 05/05/2005 01:50:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.8 0.5 3 0.4 125 8 115 255 0 0 0 0 0.1 0 0.7 -0.1 05/05/2005 02:00:00 2.7 0.7 4.6 1.5 2.7 0.7 4.9 1.1 1.6 0.6 3.8 0.4 117 12 115 255 0 0 0 0 0.4 0.1 0.9 0.2 05/05/2005 02:10:00 2.5 0.6 4.2 1.1 2.4 0.6 3.8 1.1 1.3 0.7 3 0.4 114 14 122 255 0 0 0 0 0.2 0.1 0.7 -0.1 05/05/2005 02:20:00 2 0.5 3 1.1 1.8 0.5 3 0.7 0.8 0.4 1.9 0.4 124 13 118 255 0 0 0 0 0.1 0 0.4 -0.1 05/05/2005 02:30:00 3 0.8 4.9 1.1 2.9 0.8 4.9 0.7 1.8 0.6 3.8 0.4 118 11 110 255 0 0 0 0 0 0 0.4 -0.1 05/05/2005 02:40:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 1.9 2.2 0.7 3.8 0.4 113 12 126 255 0 0 0 0 0.4 0.2 0.9 0.2 05/05/2005 02:50:00 3.8 0.5 4.9 2.6 3.7 0.5 5.3 2.3 2.2 0.6 3.8 0.4 110 11 138 255 0 0 0 0 0.6 0 0.9 0.4 05/05/2005 03:00:00 3.4 0.6 4.9 2.3 3.4 0.6 4.6 1.9 2 0.6 3.8 0.7 111 11 109 255 0 0 0 0 0.6 0 0.9 0.7 05/05/2005 03:10:00 3.3 0.6 4.6 1.9 3.2 0.7 4.6 1.9 2.1 0.6 3.8 0.4 114 10 102 255 0 0 0 0 0.7 0 1.1 0.7 05/05/2005 03:20:00 3.9 0.6 5.3 2.3 3.8 0.6 4.9 1.9 2.6 0.7 4.2 1.1 112 11 104 255 0 0 0 0 1.1 0.3 1.8 0.7 05/05/2005 03:30:00 4.5 0.5 6.1 1.9 4.5 0.5 5.7 2.3 3.2 0.6 4.6 1.5 103 9 108 255 0 0 0 0 1.7 0 1.8 1.6 05/05/2005 03:40:00 4.5 0.4 5.7 3.4 4.4 0.4 5.7 3 3.4 0.5 4.9 1.9 100 6 97 255 0 0 0 0 1.7 0 1.8 1.6 05/05/2005 03:50:00 4.3 0.5 5.3 2.6 4.3 0.5 5.3 2.3 2.9 0.7 4.6 1.1 105 10 99 255 0 0 0 0 1.6 0.1 1.8 1.4 05/05/2005 04:00:00 4.6 0.7 6.5 2.3 4.5 0.7 6.1 2.6 3.2 0.8 5.3 1.1 106 12 90 255 0 0 0 0 1.5 0.2 1.8 1.4 05/05/2005 04:10:00 4.8 0.8 6.5 1.9 4.7 0.8 6.1 1.9 3.4 0.9 5.3 1.5 104 11 106 255 0 0 0 0 2.1 0.2 2.6 1.8 05/05/2005 04:20:00 4.4 0.6 5.7 2.3 4.3 0.6 5.7 2.3 3.1 0.8 5.3 1.1 103 10 120 255 0 0 0 0 2.4 0 2.8 2.3 05/05/2005 04:30:00 4.1 0.4 5.3 2.6 4 0.5 5.3 2.3 2.9 0.6 4.6 0.7 97 8 94 255 0 0 0 0 2.4 0.1 2.8 2.3 05/05/2005 04:40:00 4.2 0.6 5.7 2.6 4.1 0.5 5.3 2.6 3 0.7 4.6 0.7 107 10 86 255 0 0 0 0 2.1 0.2 2.3 1.8 05/05/2005 04:50:00 4.3 0.9 6.1 1.1 4.2 0.9 6.5 1.5 3.1 0.8 5.3 0.7 109 13 158 255 0 0 0 0 2.3 0 2.8 2.1 05/05/2005 05:00:00 5 0.6 6.5 3 4.9 0.7 6.5 2.6 3.7 0.7 5.3 1.9 106 10 108 255 0 0 0 0 2.6 0 3.3 2.3 05/05/2005 05:10:00 4.5 0.6 5.7 2.6 4.5 0.6 5.7 2.3 3.4 0.8 5.3 1.1 100 8 80 255 0 0 0 0 2.8 0 3.3 2.6 05/05/2005 05:20:00 5 0.4 6.1 3.4 4.9 0.4 6.1 3 3.9 0.5 5.3 2.3 99 6 100 255 0 0 0 0 2.9 0 3.3 2.6 05/05/2005 05:30:00 4.5 0.5 6.1 3.4 4.4 0.5 5.7 3.4 3.4 0.6 5.3 1.9 99 7 97 255 0 0 0 0 3.5 0.2 4 3.3 05/05/2005 05:40:00 4.2 0.4 5.3 2.6 4.2 0.5 4.9 2.6 3.2 0.6 4.6 1.1 99 6 101 255 0 0 0 0 3.8 0 4.3 3.5 05/05/2005 05:50:00 4.8 0.5 5.7 2.6 4.7 0.5 5.7 2.6 3.6 0.8 5.3 1.1 103 9 101 255 0 0 0 0 4.3 0.2 4.8 3.8 05/05/2005 06:00:00 4.1 0.7 5.7 1.9 4.1 0.8 5.7 1.9 3.1 0.8 4.9 0.7 102 13 105 255 0 0 0 0 4.9 0.2 5.5 4.5 05/05/2005 06:10:00 3.9 0.6 5.7 2.3 3.9 0.6 5.7 2.3 2.8 0.8 4.2 0.7 101 11 99 255 0 0 0 0 5.8 0.3 6.2 5.2 05/05/2005 06:20:00 3.4 0.7 4.9 1.9 3.3 0.7 4.9 1.5 2.7 0.8 4.6 0.7 100 13 83 255 0 0 0 0 6.6 0.2 7 6.2 05/05/2005 06:30:00 3.3 0.7 5.7 1.9 3.2 0.7 4.9 1.5 2.5 0.7 4.6 0.7 92 15 98 255 0 0 0 0 7.1 0 7.3 6.7 05/05/2005 06:40:00 3.3 0.6 5.3 1.5 3.2 0.6 5.3 1.5 2.7 0.5 4.2 1.1 97 10 83 255 0 0 0 0 6.6 0 7 6.5 05/05/2005 06:50:00 2.8 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.2 0.7 3.8 0.7 110 16 112 255 0 0 0 0 6.6 0 6.7 6.5 05/05/2005 07:00:00 3.1 0.8 4.9 1.5 3 0.8 5.3 1.5 2.5 0.9 4.2 0.4 110 17 106 255 0 0 0 0 6.9 0.1 7.3 6.5 05/05/2005 07:10:00 3.7 0.5 4.9 2.3 3.6 0.6 4.9 2.3 3.4 0.6 4.6 1.5 103 9 111 255 0 0 0 0 7.1 0 7.3 7 05/05/2005 07:20:00 3.1 0.6 4.6 1.5 3 0.6 4.2 1.1 2.6 0.7 4.2 0.7 103 12 105 255 0 0 0 0 7.6 0.1 7.8 7.3 05/05/2005 07:30:00 3.7 0.4 4.9 2.6 3.7 0.4 4.6 2.3 3.2 0.6 4.6 1.5 105 9 113 255 0 0 0 0 8 0 8.3 7.8 05/05/2005 07:40:00 3.3 0.6 4.9 1.9 3.2 0.7 4.6 1.5 2.9 0.7 4.6 1.1 94 14 97 255 0 0 0 0 8.5 0.1 8.8 8.3 05/05/2005 07:50:00 2.8 0.8 4.2 1.1 2.7 0.8 4.2 0.7 2.2 1 4.2 0.4 94 19 90 255 0 0 0 0 8.9 0.3 9.6 8.5 05/05/2005 08:00:00 2 0.6 3.8 0.4 1.9 0.7 3.8 0.4 1.6 0.8 3.8 0.4 70 22 38 255 0 0 0 0 10 0.3 10.6 9.6 05/05/2005 08:10:00 2.5 0.7 4.2 0.7 2.4 0.7 4.2 0.7 2 0.8 3.8 0.4 77 19 83 255 0 0 0 0 11 0.2 11.4 10.6 05/05/2005 08:20:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.5 2.5 0.7 4.2 0.7 72 21 67 255 0 0 0 0 11.1 0 11.4 11.1 05/05/2005 08:30:00 2.3 0.9 4.6 0.4 2.3 0.9 4.6 0.4 1.8 0.8 4.2 0.4 62 22 96 255 0 0 0 0 11.5 0.2 12.2 11.1 05/05/2005 08:40:00 3.1 1 4.9 0.7 2.9 1 4.6 0.4 2.5 1 4.6 0.4 43 19 40 255 0 0 0 0 12.3 0.2 12.7 11.9 05/05/2005 08:50:00 3.5 1.1 6.5 1.1 3.4 1.1 6.5 1.5 2.7 1.1 6.8 0.4 47 24 28 255 0 0 0 0 12.8 0 13 12.7 05/05/2005 09:00:00 4.5 1.4 7.6 0.7 4.4 1.5 7.2 0.4 3.6 1.2 6.5 0.4 37 27 38 255 0 0 0 0 13.1 0 13.5 12.7 05/05/2005 09:10:00 5.9 1.5 9.9 1.9 5.8 1.5 9.5 2.3 4.8 1.5 8.8 1.9 33 18 353 255 0 0 0 0 13.3 0.1 13.8 13 05/05/2005 09:20:00 6.1 1.4 9.5 3 6.1 1.4 9.5 2.6 5.1 1.5 8.8 2.3 42 19 38 255 0 0 0 0 13.4 0.3 14.4 12.7 05/05/2005 09:30:00 7.5 1.6 10.7 3.4 7.5 1.6 10.7 3.8 6.1 1.5 11.1 2.3 24 14 19 255 0 0 0 0 13.8 0.3 14.6 13 05/05/2005 09:40:00 8.7 1.3 12.6 5.7 8.7 1.3 13 5.3 7.3 1.5 11.8 4.2 27 15 26 255 0 0 0 0 13.5 0.2 14.4 13 05/05/2005 09:50:00 7.5 1.7 11.8 3.4 7.5 1.8 11.5 3.4 6.1 1.9 9.9 1.5 18 12 21 255 0 0 0 0 13.9 0.2 14.6 13.5 05/05/2005 10:00:00 7.1 1.4 10.7 3.4 7.1 1.4 10.7 3.4 5.7 1.5 9.5 1.9 20 15 32 255 0 0 0 0 14.6 0.2 15.2 14.1 05/05/2005 10:10:00 6.9 1.5 10.7 3.4 6.9 1.5 11.1 3.4 5.5 1.8 10.3 2.3 14 17 42 255 0 0 0 0 14.1 0.1 15.2 13.8 05/05/2005 10:20:00 7.2 1.4 11.5 3.4 7.2 1.4 11.8 3 5.4 1.5 9.1 2.3 8 17 356 255 0 0 0 0 15 0.2 15.7 14.6 05/05/2005 10:30:00 7.8 1.8 11.8 3.8 7.8 1.9 11.8 3.8 6.2 1.9 10.3 2.3 19 11 22 255 0 0 0 0 15.7 0.3 16.6 15.2 05/05/2005 10:40:00 6.9 1.4 9.9 3.4 6.8 1.4 9.9 3.8 5.4 1.5 9.5 2.3 16 12 23 255 0 0 0 0 16 0.4 16.8 15.5 05/05/2005 10:50:00 7.9 1.7 11.8 3.8 7.8 1.7 11.5 3.8 6.3 1.6 11.1 2.3 19 13 19 255 0 0 0 0 16.1 0.2 16.8 15.7 05/05/2005 11:00:00 6.5 1.5 10.3 2.6 6.4 1.5 10.3 1.9 4.8 1.7 9.9 1.1 7 14 6 255 0 0 0 0 15.8 0.2 16.3 15.5 05/05/2005 11:10:00 7.3 1.5 10.7 3 7.2 1.5 10.3 3 5.2 1.7 9.9 1.1 5 13 4 255 0 0 0 0 15.9 0 16.3 15.7 05/05/2005 11:20:00 6.1 2 10.3 2.3 6.1 2 10.3 1.5 4.5 1.7 8.8 1.5 5 20 39 255 0 0 0 0 15.4 0 15.7 15.2 05/05/2005 11:30:00 7.2 1.3 9.9 3.4 7.1 1.3 9.9 3.4 5.5 1.5 9.1 1.9 10 12 22 255 0 0 0 0 15.7 0 16 15.2 05/05/2005 11:40:00 5.8 1.3 8.8 2.3 5.7 1.3 8.8 2.3 4.3 1.5 9.1 1.1 8 15 2 255 0 0 0 0 15.9 0.3 16.6 15.5 05/05/2005 11:50:00 6.6 1.7 9.9 3 6.5 1.7 9.9 3 5.2 1.5 9.5 1.9 17 12 32 255 0 0 0 0 16.4 0.1 16.8 16 05/05/2005 12:00:00 7 1.8 12.2 3 7 1.9 12.2 2.6 5.8 1.7 11.1 2.3 11 15 12 255 0 0 0 0 16.6 0 16.8 16.3 05/05/2005 12:10:00 6.8 1.6 10.3 2.6 6.7 1.6 9.9 2.6 5.1 1.7 9.9 1.5 10 16 18 255 0 0 0 0 15.7 0.3 16.6 15.2 05/05/2005 12:20:00 6.6 1.5 10.7 3 6.5 1.5 10.3 3 5.3 1.6 9.9 1.9 14 12 1 255 0 0 0 0 15.3 0 15.7 15.2 05/05/2005 12:30:00 5.9 1.5 9.5 1.9 5.8 1.5 9.5 1.9 4.4 1.6 7.6 0.7 9 17 38 255 0 0 0 0 15.5 0.2 16 15.2 05/05/2005 12:40:00 6.7 1.8 11.1 2.3 6.6 1.9 11.1 1.9 5.1 2 10.7 0.4 7 17 5 255 0 0 0 0 16.1 0 16.3 16 05/05/2005 12:50:00 6.8 1.6 10.7 1.5 6.8 1.6 10.7 1.5 5.2 1.8 11.1 1.1 10 13 12 255 0 0 0 0 16.1 0 16.3 16 05/05/2005 13:00:00 6.5 1.5 10.3 3 6.5 1.5 10.3 3 5 1.7 9.1 1.1 11 14 6 255 0 0 0 0 15.9 0.1 16.3 15.7 05/05/2005 13:10:00 7.7 1.5 11.1 4.2 7.7 1.5 11.1 4.2 6.1 1.7 9.1 1.9 17 19 7 255 0 0 0 0 15.5 0 15.7 15.5 05/05/2005 13:20:00 6.9 1.3 10.7 3.4 6.9 1.4 10.7 3 5.2 1.6 11.5 1.5 0 15 1 255 0 0 0 0 15.6 0 16 15.5 05/05/2005 13:30:00 6.2 1.3 9.9 3.4 6.2 1.4 9.5 3 4.8 1.3 8.4 1.5 12 13 8 255 0 0 0 0 15.5 0 15.7 15.5 05/05/2005 13:40:00 6.3 1.8 11.1 1.9 6.2 1.8 11.5 1.5 4.8 1.6 8.8 0.7 13 14 11 255 0 0 0 0 15.5 0 15.7 15.5 05/05/2005 13:50:00 7.3 1.5 10.7 3.4 7.3 1.5 11.5 3 5.7 1.7 10.3 2.3 13 15 23 255 0 0 0 0 15.2 0 15.5 15.2 05/05/2005 14:00:00 7.4 1.5 11.1 4.2 7.4 1.5 11.1 4.2 6 1.8 10.3 2.3 18 11 13 255 0 0 0 0 15 0 15.5 14.9 05/05/2005 14:10:00 6.7 1.6 11.1 3 6.6 1.6 11.1 3 5.2 1.5 8.4 2.3 18 16 35 255 0 0 0 0 15.2 0 15.5 15.2 05/05/2005 14:20:00 7.7 1.7 11.5 3 7.7 1.7 11.5 3 6.4 1.6 10.3 2.6 19 12 20 255 0 0 0 0 14.9 0 15.2 14.6 05/05/2005 14:30:00 6.9 2.2 11.8 1.1 6.8 2.3 12.2 0.4 5.4 2.3 10.7 0.4 14 15 6 255 0 0 0 0 15 0 15.2 14.9 05/05/2005 14:40:00 6.4 1.5 10.7 2.3 6.3 1.5 10.7 1.9 4.8 1.7 9.9 0.7 8 15 9 255 0 0 0 0 14.8 0 15.2 14.6 05/05/2005 14:50:00 7.5 1.5 13 3.4 7.5 1.5 13 3.4 5.8 1.7 10.3 1.9 12 12 35 255 0 0 0 0 14.8 0 15.2 14.6 05/05/2005 15:00:00 7 2 10.7 2.3 6.9 2 10.7 2.3 5.7 1.8 9.5 1.9 23 15 37 255 0 0 0 0 14.4 0 14.9 14.4 05/05/2005 15:10:00 6.6 1.9 11.5 1.9 6.5 2 11.1 1.5 5.3 1.7 9.9 2.3 11 17 35 255 0 0 0 0 14.2 0.2 14.9 13.8 05/05/2005 15:20:00 6.1 1.6 10.7 2.3 6 1.6 10.7 1.9 4.5 1.7 8.4 1.1 6 19 25 255 0 0 0 0 13.9 0 14.6 13.5 05/05/2005 15:30:00 6.1 2 9.5 1.5 6 2.1 9.9 1.1 4.6 2.1 9.5 0.4 4 21 3 255 0 0 0 0 13.7 0 14.4 13.3 05/05/2005 15:40:00 4.9 2.2 9.9 1.5 4.8 2.3 9.5 1.1 3.6 2 8.4 0.4 6 17 16 255 0 0 0 0 13.7 0.1 14.4 13.5 05/05/2005 15:50:00 6.3 1.6 11.1 2.6 6.3 1.7 11.1 1.1 4.7 1.7 9.5 1.1 11 17 1 255 0 0 0 0 13.9 0 14.4 13.5 05/05/2005 16:00:00 7.1 1.2 10.3 3.8 7 1.2 10.3 3 5.4 1.5 9.1 1.9 8 16 22 255 0 0 0 0 13.5 0.1 14.1 13 05/05/2005 16:10:00 7.5 1.5 11.8 3 7.5 1.5 11.8 3.4 5.6 1.8 11.1 1.9 8 14 22 255 0 0 0 0 13.2 0.1 13.8 13 05/05/2005 16:20:00 6.8 1.8 11.5 1.9 6.7 1.9 11.5 1.5 5.2 1.9 10.7 0.4 10 12 11 255 0 0 0 0 13.3 0.1 13.8 13 05/05/2005 16:30:00 8 1.4 12.6 4.6 7.9 1.4 13 4.6 6.2 1.9 10.7 1.9 16 17 13 255 0 0 0 0 13.5 0 13.8 13.3 05/05/2005 16:40:00 6.9 2.1 11.1 2.3 6.8 2.1 11.1 2.3 5.7 1.9 10.7 1.1 25 17 0 255 0 0 0 0 13.5 0 14.1 13.3 05/05/2005 16:50:00 7.3 1.5 10.3 3.8 7.2 1.6 10.3 3.4 5.7 1.9 8.8 0.7 18 16 1 255 0 0 0 0 13.6 0 14.1 13.3 05/05/2005 17:00:00 8.7 1.3 12.2 5.7 8.7 1.3 12.2 5.3 7 1.6 11.5 3.4 18 12 20 255 0 0 0 0 13.3 0.2 14.1 13 05/05/2005 17:10:00 8.4 1.7 11.8 4.2 8.3 1.7 11.8 3.8 6.7 1.8 11.8 2.6 20 12 28 255 0 0 0 0 13.1 0.1 13.5 12.7 05/05/2005 17:20:00 8 1.9 11.5 3 7.9 2 11.5 2.6 6.3 2.1 10.7 1.5 20 15 20 255 0 0 0 0 12.8 0 13.3 12.7 05/05/2005 17:30:00 7.8 1.8 11.8 3.8 7.7 1.8 11.8 3.4 6.3 1.7 10.7 2.6 18 12 14 255 0 0 0 0 12.6 0.1 13 12.5 05/05/2005 17:40:00 7.1 1.9 11.8 2.3 7.1 2 11.8 1.9 5.8 1.9 11.5 1.1 18 16 23 255 0 0 0 0 12.5 0.1 13 12.2 05/05/2005 17:50:00 6.6 1.7 9.9 2.6 6.5 1.7 9.5 1.9 5.1 1.8 9.5 1.5 12 13 30 255 0 0 0 0 12.3 0 12.7 12.2 05/05/2005 18:00:00 5.5 1.7 10.3 1.1 5.5 1.7 10.3 1.1 4.1 1.7 9.5 1.1 13 15 14 255 0 0 0 0 12 0 12.2 11.9 05/05/2005 18:10:00 6.9 1.2 9.9 4.2 6.9 1.3 9.9 3.8 5.4 1.5 9.5 1.9 16 13 12 255 0 0 0 0 11.8 0 11.9 11.7 05/05/2005 18:20:00 7.4 2.1 11.5 3 7.4 2.1 11.5 1.9 5.9 2.3 11.5 0.7 16 15 27 255 0 0 0 0 11.7 0 11.9 11.7 05/05/2005 18:30:00 7.8 2 11.8 3 7.7 2 12.2 2.6 6.1 1.9 11.1 1.9 21 13 7 255 0 0 0 0 11.5 0 11.7 11.4 05/05/2005 18:40:00 7.1 1.4 9.9 3 7 1.5 9.9 3 5.5 1.7 9.9 1.1 12 13 21 255 0 0 0 0 11.3 0 11.7 11.1 05/05/2005 18:50:00 7.3 1.6 11.5 3 7.3 1.7 11.5 2.6 5.7 1.9 9.5 1.1 9 12 0 255 0 0 0 0 11.1 0 11.4 10.9 05/05/2005 19:00:00 7.3 1.7 11.8 3.8 7.2 1.7 11.8 3 5.8 1.7 10.3 1.9 15 11 1 255 0 0 0 0 11 0 11.4 10.9 05/05/2005 19:10:00 7.1 1.5 11.1 3.8 7 1.5 11.1 3 5.5 1.7 10.3 1.5 9 13 25 255 0 0 0 0 10.9 0 11.4 10.9 05/05/2005 19:20:00 7.9 1.5 11.8 4.6 7.9 1.5 12.2 4.2 6 1.8 10.3 2.3 11 12 12 255 0 0 0 0 10.9 0 11.4 10.9 05/05/2005 19:30:00 8 1.8 12.6 3.8 8 1.8 12.2 3.4 6.3 2 11.5 1.1 15 12 3 255 0 0 0 0 10.8 0 11.1 10.6 05/05/2005 19:40:00 7.8 1.5 11.5 4.2 7.7 1.6 11.5 4.2 6 1.8 9.9 1.9 14 12 12 255 0 0 0 0 10.7 0 11.1 10.6 05/05/2005 19:50:00 8 2 13 3 8 2 13 2.6 6.3 2.2 11.1 1.5 14 13 40 255 0 0 0 0 10.7 0 10.9 10.6 05/05/2005 20:00:00 6.8 1.7 10.7 2.6 6.8 1.7 10.3 3 5.4 1.8 9.5 1.1 20 14 15 255 0 0 0 0 10.6 0 10.6 10.6 05/05/2005 20:10:00 6.8 1.1 10.3 3.8 6.7 1.2 9.9 3.8 5.4 1.4 8.8 2.3 17 13 0 255 0 0 0 0 10.5 0 10.6 10.6 05/05/2005 20:20:00 7.2 1.5 11.8 3.8 7.1 1.6 12.6 3.4 5.7 1.7 9.5 1.9 15 12 1 255 0 0 0 0 10.5 0 10.6 10.6 05/05/2005 20:30:00 6.7 1.3 10.3 2.6 6.6 1.3 10.3 2.6 5.2 1.4 8.8 1.9 19 14 28 255 0 0 0 0 10.5 0 10.6 10.3 05/05/2005 20:40:00 6.1 1.3 10.3 2.6 6 1.3 9.9 2.6 5.1 1.4 8.8 1.9 36 15 23 255 0 0 0 0 10.5 0 10.6 10.3 05/05/2005 20:50:00 5 1.3 9.1 2.6 4.9 1.3 9.1 1.9 4.2 1.3 7.6 1.5 39 16 48 255 0 0 0 0 10.4 0 10.6 10.3 05/05/2005 21:00:00 4.9 1 7.2 2.6 4.8 1 7.2 2.6 4.2 1.1 7.6 1.5 52 15 54 255 0 0 0 0 10.3 0 10.6 10.3 05/05/2005 21:10:00 4.7 0.9 7.2 2.6 4.6 1 7.6 2.3 3.9 1 6.8 1.1 63 16 32 255 0 0 0 0 10.1 0 10.3 9.8 05/05/2005 21:20:00 5.5 1.3 10.7 2.6 5.4 1.3 10.7 2.6 4.5 1.3 9.5 0.7 43 17 22 255 0 0 0 0 10 0 10.3 9.8 05/05/2005 21:30:00 5.1 1.3 9.1 1.9 5.1 1.3 9.1 1.9 4.1 1.3 7.6 1.5 41 18 15 255 0 0 0 0 10.2 0 10.3 10.1 05/05/2005 21:40:00 5.7 1.3 9.5 3.4 5.6 1.3 9.5 3 4.6 1.3 9.1 1.9 27 17 1 255 0 0 0 0 10.2 0 10.3 10.1 05/05/2005 21:50:00 7.5 1.7 11.8 3.8 7.5 1.7 12.2 3.8 6.3 1.7 11.8 2.6 25 14 18 255 0 0 0 0 10.2 0 10.3 10.1 05/05/2005 22:00:00 6.3 1.5 11.8 3.4 6.2 1.6 11.5 3 5.1 1.6 11.1 2.3 34 16 33 255 0 0 0 0 10.1 0 10.3 10.1 05/05/2005 22:10:00 7.5 1.2 10.7 4.2 7.5 1.2 10.3 4.2 6.1 1.3 9.5 3.4 25 15 11 255 0 0 0 0 10.1 0 10.3 10.1 05/05/2005 22:20:00 8 1.5 11.8 4.2 8 1.5 11.8 3.8 6.4 1.7 11.5 3 20 12 15 255 0 0 0 0 10.1 0 10.3 10.1 05/05/2005 22:30:00 6.6 1.7 11.8 3.4 6.6 1.7 11.8 3 5.4 1.7 10.7 1.9 21 11 28 255 0 0 0 0 10 0 10.3 10.1 05/05/2005 22:40:00 5.9 1.2 11.1 3.4 5.8 1.2 11.1 3 4.8 1.3 10.7 2.3 24 12 34 255 0 0 0 0 10 0 10.1 9.8 05/05/2005 22:50:00 5.6 1.2 9.1 3 5.5 1.2 9.1 2.6 4.2 1.3 8 1.1 19 15 12 255 0 0 0 0 9.9 0 10.1 9.8 05/05/2005 23:00:00 4.7 1 7.2 2.3 4.7 1 7.2 2.6 3.8 1.1 6.5 1.5 35 17 38 255 0 0 0 0 9.8 0 9.8 9.8 05/05/2005 23:10:00 5.2 1.2 9.1 3 5.1 1.2 9.1 2.3 4.2 1.2 8 1.5 41 15 29 255 0 0 0 0 9.7 0 9.8 9.6 05/05/2005 23:20:00 7.3 1.3 11.1 4.2 7.3 1.3 11.1 3.8 6 1.4 9.5 2.3 38 13 42 255 0 0 0 0 9.7 0 9.8 9.6 05/05/2005 23:30:00 7.8 1.2 11.8 5.3 7.7 1.2 11.1 4.2 6.7 1.3 10.3 3.4 28 14 33 255 0 0 0 0 9.8 0 9.8 9.6 05/05/2005 23:40:00 5.8 1.1 9.5 3 5.8 1.2 9.5 2.6 4.6 1.4 9.1 1.5 29 18 24 255 0 0 0 0 9.6 0 9.8 9.6 05/05/2005 23:50:00 6.4 1.1 8.8 4.2 6.4 1.1 9.1 3.8 5.5 1.3 8.8 3 36 15 54 255 0 0 0 0 9.6 0.1 9.8 9.6 05/06/2005 00:00:00 6.5 1.1 9.9 3.8 6.5 1.1 9.5 3.8 5.5 1 8.4 2.6 31 13 48 255 0 0 0 0 9.6 0 9.8 9.6 05/06/2005 00:10:00 6.3 1.2 9.5 3 6.3 1.3 9.5 3.4 5.2 1.5 9.1 1.5 37 17 33 255 0 0 0 0 9.6 0 9.8 9.6 05/06/2005 00:20:00 5 1.2 8.4 1.1 4.9 1.2 8 1.5 4 1.2 6.8 1.5 54 20 77 255 0 0 0 0 9.6 0 9.6 9.6 05/06/2005 00:30:00 5.1 1.5 9.9 2.3 5.1 1.5 9.9 1.9 4.3 1.5 9.9 1.5 58 17 62 255 0 0 0 0 9.5 0 9.6 9.3 05/06/2005 00:40:00 5.8 1.2 8.4 2.6 5.8 1.2 9.1 2.3 4.9 1.3 8 1.5 59 17 58 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 00:50:00 5.1 1 7.6 2.6 5.1 1 7.2 2.6 4.1 1 6.8 1.9 61 14 55 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 01:00:00 5.2 1.2 8.4 2.3 5.2 1.1 8.4 2.3 4.1 1.3 8 1.5 56 15 40 255 0 0 0 0 9.1 0 9.3 9 05/06/2005 01:10:00 5.8 1.1 8.8 3 5.8 1.1 8.8 3 4.8 1.1 7.6 2.3 52 15 55 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 01:20:00 6.4 1.2 9.5 3.4 6.4 1.2 9.1 3.4 5.4 1.2 8.4 2.3 45 13 39 255 0 0 0 0 9.3 0 9.6 9.3 05/06/2005 01:30:00 5 1.1 7.6 2.3 5 1.1 7.6 1.9 4 1 6.8 1.9 59 16 50 255 0 0 0 0 9.5 0 9.6 9.3 05/06/2005 01:40:00 4.8 1 8.4 2.3 4.7 1.1 8.4 1.9 3.9 1 7.6 0.7 55 17 45 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 01:50:00 5.5 1.1 8.8 2.6 5.5 1.1 8.8 2.6 4.9 1.2 8 1.5 55 17 67 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 02:00:00 5 1 7.2 2.6 4.9 1 7.2 2.6 4.1 1 6.8 1.5 54 14 50 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 02:10:00 5.9 1.2 8.8 3 5.9 1.3 9.1 2.6 5 1.3 8.4 1.5 46 13 46 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 02:20:00 7.1 1.3 10.3 3.8 7 1.4 10.3 3.4 5.9 1.3 9.1 2.3 37 12 42 255 0 0 0 0 9.3 0 9.3 9.3 05/06/2005 02:30:00 6.8 1.2 10.7 3.4 6.8 1.3 10.7 3.4 5.7 1.5 8.8 2.3 44 12 46 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 02:40:00 6.9 1.1 9.5 3.8 6.8 1.2 9.5 3.8 5.8 1.2 8.8 3 45 11 44 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 02:50:00 7.3 1.2 10.3 4.2 7.2 1.2 10.7 4.2 6.3 1.3 9.5 3 41 12 27 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 03:00:00 7.1 1.2 10.3 3.8 7 1.2 10.7 3.8 6 1.4 10.3 2.6 37 12 35 255 0 0 0 0 9.1 0 9.3 9 05/06/2005 03:10:00 6.6 1.1 9.5 3.8 6.6 1.1 9.5 4.2 5.5 1.2 8.8 2.6 45 14 40 255 0 0 0 0 9.2 0 9.3 9.3 05/06/2005 03:20:00 5.6 1.1 8.8 3 5.5 1.2 8.8 2.6 4.7 1.2 8 2.3 51 14 53 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 03:30:00 5.5 1 8.4 3.4 5.5 1.1 8 2.3 4.4 1 6.8 2.3 56 15 51 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 03:40:00 5.3 1.2 8.8 2.3 5.3 1.2 9.1 2.6 4.4 1.2 7.2 1.5 52 15 47 255 0 0 0 0 9.2 0 9.3 9 05/06/2005 03:50:00 5.4 0.8 7.6 3.4 5.3 0.9 7.6 2.6 4.5 1 7.6 2.3 40 12 28 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 04:00:00 3.7 0.9 6.5 1.9 3.6 1 6.5 1.5 2.8 0.9 6.1 0.7 52 13 48 255 0 0 0 0 9.3 0 9.6 9 05/06/2005 04:10:00 4 0.8 5.7 1.1 4 0.9 5.7 1.1 3.1 1 6.1 0.4 57 14 49 255 0 0 0 0 9 0 9.3 9 05/06/2005 04:20:00 3.8 0.8 5.3 1.5 3.8 0.8 5.7 1.5 2.9 1 5.3 0.4 52 13 52 255 0 0 0 0 8.9 0 9 9 05/06/2005 04:30:00 3.4 0.6 4.9 1.5 3.3 0.7 5.3 1.1 2.7 0.7 4.2 0.7 59 15 40 255 0 0 0 0 8.9 0 9 8.8 05/06/2005 04:40:00 3.8 0.7 5.7 1.9 3.7 0.7 5.3 1.9 3 0.8 5.3 1.1 67 13 82 255 0 0 0 0 8.8 0 9 8.8 05/06/2005 04:50:00 4.1 0.9 6.1 1.9 4.1 0.9 6.1 1.9 3.3 0.9 5.7 0.4 65 13 62 255 0 0 0 0 8.8 0 9 8.8 05/06/2005 05:00:00 3.4 0.6 4.9 1.5 3.2 0.7 4.9 1.5 2.5 0.7 4.9 1.1 74 11 64 255 0 0 0 0 8.7 0 9 8.5 05/06/2005 05:10:00 3.6 0.6 4.9 1.9 3.4 0.7 4.9 1.1 2.7 0.7 4.6 1.1 91 12 93 255 0 0 0 0 8.5 0 8.8 8.5 05/06/2005 05:20:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.9 2.6 0.7 4.6 0.7 102 12 115 255 0 0 0 0 8.3 0 8.5 8 05/06/2005 05:30:00 4 0.6 5.7 2.6 3.9 0.6 5.7 1.9 3 0.7 4.9 0.7 82 12 76 255 0 0 0 0 8 0 8.3 8 05/06/2005 05:40:00 2.8 0.9 4.9 1.1 2.6 1 4.9 0.7 2 0.9 3.8 0.4 86 14 81 255 0 0 0 0 8.2 0 8.5 8 05/06/2005 05:50:00 2.4 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1.5 0.5 3 0.4 94 11 96 255 0 0 0 0 8.1 0 8.5 8 05/06/2005 06:00:00 2.8 0.6 4.9 1.5 2.7 0.7 4.9 1.1 2.1 0.8 4.6 0.4 101 13 95 255 0 0 0 0 8 0 8.3 8 05/06/2005 06:10:00 2.6 0.5 4.2 1.5 2.4 0.5 3.8 1.1 1.6 0.6 3 0.4 100 12 96 255 0 0 0 0 8.1 0 8.3 8 05/06/2005 06:20:00 2.8 0.4 3.8 1.5 2.7 0.5 3.4 1.5 2.1 0.5 3 0.4 97 9 92 255 0 0 0 0 8.3 0 8.5 8.3 05/06/2005 06:30:00 2.8 0.6 4.2 1.1 2.6 0.7 4.2 0.7 2.1 0.6 3.4 0.4 103 11 94 255 0 0 0 0 8.4 0 8.5 8.3 05/06/2005 06:40:00 2.9 0.5 3.8 1.1 2.7 0.6 3.8 1.1 2 0.7 3.8 0.4 109 11 112 255 0 0 0 0 8.4 0 8.5 8.5 05/06/2005 06:50:00 3.1 0.6 4.6 1.1 3 0.7 4.6 0.7 2.2 0.7 3.8 0.4 114 13 121 255 0 0 0 0 8.4 0 8.5 8.5 05/06/2005 07:00:00 3.3 0.6 4.6 1.5 3.2 0.6 4.6 1.5 2.5 0.6 4.2 1.1 113 10 110 255 0 0 0 0 8.4 0 8.5 8.5 05/06/2005 07:10:00 3.8 0.6 4.9 2.3 3.7 0.6 4.9 1.9 2.9 0.7 4.9 1.1 109 10 106 255 0 0 0 0 8.4 0 8.5 8.5 05/06/2005 07:20:00 3.2 0.7 4.9 1.1 3.1 0.7 4.9 1.5 2.4 0.8 4.2 0.4 108 14 101 255 0 0 0 0 8.6 0 8.8 8.5 05/06/2005 07:30:00 3.2 0.6 4.6 1.5 3 0.7 4.6 1.1 2.5 0.6 4.2 0.7 106 11 91 255 0 0 0 0 9 0 9 8.8 05/06/2005 07:40:00 3.1 0.6 4.6 1.5 3 0.6 4.2 1.1 2.6 0.8 4.2 0.4 104 11 97 255 0 0 0 0 9.4 0 9.6 9 05/06/2005 07:50:00 3.2 0.7 4.6 1.1 3 0.8 4.6 0.7 2.6 0.7 4.2 0.7 110 12 94 255 0 0 0 0 9.7 0 10.1 9.6 05/06/2005 08:00:00 3.9 0.6 5.3 1.9 3.7 0.7 5.3 1.5 3.3 0.6 4.6 1.5 109 10 113 255 0 0 0 0 10.1 0 10.3 9.8 05/06/2005 08:10:00 3.9 0.7 4.9 2.3 3.8 0.7 4.9 1.5 3.3 0.8 4.9 0.7 104 11 106 255 0 0 0 0 10.1 0 10.3 10.1 05/06/2005 08:20:00 3.3 0.6 4.6 1.1 3.2 0.6 4.2 1.1 2.9 0.6 4.2 1.1 110 10 105 255 0 0 0 0 10.3 0 10.6 10.3 05/06/2005 08:30:00 3.3 0.7 4.9 1.5 3.1 0.7 5.3 1.1 3 0.7 4.6 0.4 105 9 99 255 0 0 0 0 10.7 0.2 11.1 10.6 05/06/2005 08:40:00 3 0.5 4.2 1.1 2.8 0.6 3.8 0.7 2.6 0.7 4.2 0.4 104 11 111 255 0 0 0 0 11.2 0 11.4 11.1 05/06/2005 08:50:00 2.7 0.6 3.8 1.1 2.5 0.7 3.8 0.4 2.2 0.7 4.2 0.4 106 15 102 255 0 0 0 0 11.5 0 11.7 11.1 05/06/2005 09:00:00 2.2 0.6 3.4 0.4 1.9 0.7 3.4 0.4 1.8 0.7 3 0.4 100 14 103 255 0 0 0 0 11.7 0 11.9 11.4 05/06/2005 09:10:00 1.9 0.7 3.4 0.4 1.7 0.8 3 0.4 1.7 0.7 3.4 0.4 110 23 96 255 0 0 0 0 12.2 0.2 12.5 11.9 05/06/2005 09:20:00 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.4 0.6 3 0.4 111 27 115 255 0 0 0 0 12.4 0 12.7 12.2 05/06/2005 09:30:00 1.3 0.6 2.6 0.4 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 96 28 99 255 0 0 0 0 12.7 0.1 13.3 12.5 05/06/2005 09:40:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 103 20 106 255 0 0 0 0 13 0.1 13.5 12.7 05/06/2005 09:50:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 47 36 23 255 0 0 0 0 13.3 0 13.8 13 05/06/2005 10:00:00 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 71 35 74 255 0 0 0 0 13.8 0.1 14.6 13.5 05/06/2005 10:10:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1 19 351 255 0 0 0 0 14.2 0.1 14.6 13.8 05/06/2005 10:20:00 1.1 0.7 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 51 53 31 255 0 0 0 0 14.6 0.1 15.2 14.4 05/06/2005 10:30:00 1.8 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.4 0.8 3.4 0.4 25 22 29 255 0 0 0 0 14.7 0 15.2 14.6 05/06/2005 10:40:00 2.9 1 6.1 0.4 2.8 1.1 5.7 0.4 2.2 1.1 4.9 0.4 23 23 18 255 0 0 0 0 15 0.2 15.7 14.6 05/06/2005 10:50:00 2.4 0.6 4.2 0.7 2.2 0.7 3.8 0.4 1.7 0.8 3.8 0.4 14 17 23 255 0 0 0 0 15.5 0.1 16 15.2 05/06/2005 11:00:00 2.1 0.7 4.2 0.4 1.8 0.7 4.2 0.4 1.3 0.7 3 0.4 354 19 4 255 0 0 0 0 15.6 0.2 16.3 15.2 05/06/2005 11:10:00 2.6 0.7 4.2 0.7 2.2 0.8 3.8 0.4 1.7 0.8 3.4 0.4 351 28 336 255 0 0 0 0 15.9 0 16.6 15.7 05/06/2005 11:20:00 1.9 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.4 0.9 3.4 0.4 349 24 321 255 0 0 0 0 15.7 0 16.3 15.5 05/06/2005 11:30:00 1.7 0.9 3.4 0.4 1.4 0.9 3.4 0.4 1.2 0.7 3 0.4 319 43 318 255 0 0 0 0 15.9 0 16.3 15.7 05/06/2005 11:40:00 1.9 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.7 3.4 0.4 344 26 304 255 0 0 0 0 15.9 0 16.3 15.7 05/06/2005 11:50:00 1.9 0.4 3.8 0.7 1.6 0.5 3.4 0.7 1.3 0.6 3 0.4 302 16 292 255 0 0 0 0 15.6 0 16 15.5 05/06/2005 12:00:00 1.4 0.6 3 0.4 1 0.7 3 0.4 0.7 0.5 2.6 0.4 345 39 294 255 0 0 0 0 16.1 0 16.3 15.7 05/06/2005 12:10:00 1.1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.5 0.4 2.3 0.4 46 56 38 255 0 0 0 0 16.6 0.3 17.1 16.3 05/06/2005 12:20:00 1.1 0.7 3 0.4 0.8 0.6 3 0.4 0.7 0.6 3 0.4 325 69 310 255 0 0 0 0 17.1 0 17.1 16.8 05/06/2005 12:30:00 1.2 0.9 4.6 0.4 1 1 4.6 0.4 0.9 0.8 3.4 0.4 14 51 294 255 0 0 0 0 16.8 0 16.8 16.8 05/06/2005 12:40:00 2.1 0.8 4.2 0.4 1.9 0.9 3.8 0.4 1.7 1 3.4 0.4 308 24 296 255 0 0 0 0 16.9 0 17.1 16.8 05/06/2005 12:50:00 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.6 3.4 0.4 314 47 12 255 0 0 0 0 16.4 0.2 17.1 16.3 05/06/2005 13:00:00 1.1 0.6 3 0.4 0.9 0.7 3 0.4 0.9 0.6 3 0.4 58 58 106 255 0 0 0 0 16.6 0 17.1 16.6 05/06/2005 13:10:00 1.2 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.6 0.4 1.9 0.4 267 98 61 255 0 0 0 0 17.3 0.1 17.7 16.8 05/06/2005 13:20:00 1.3 0.7 3 0.4 1.1 0.7 2.6 0.4 1.1 0.8 3 0.4 275 53 256 255 0 0 0 0 17.3 0.1 18 17.1 05/06/2005 13:30:00 2.3 0.8 4.6 0.4 2.1 0.8 4.2 0.4 1.7 1 4.6 0.4 258 22 237 255 0 0 0 0 17.2 0 17.7 16.8 05/06/2005 13:40:00 2.2 0.7 3.4 0.4 2 0.8 3.8 0.4 1.5 0.8 3.4 0.4 299 22 307 255 0 0 0 0 17 0 17.4 16.8 05/06/2005 13:50:00 1.3 0.9 3.8 0.4 1.1 0.9 3.8 0.4 0.8 0.7 3 0.4 321 47 252 255 0 0 0 0 17.1 0 17.7 16.8 05/06/2005 14:00:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 50 82 262 255 0 0 0 0 17.5 0.1 18 17.1 05/06/2005 14:10:00 1.4 0.8 3.4 0.4 1.2 0.8 3 0.4 1 0.7 2.6 0.4 322 39 310 255 0 0 0 0 17.8 0 18.2 17.4 05/06/2005 14:20:00 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.1 0.7 3 0.4 260 58 270 255 0 0 0 0 17.2 0 17.7 16.8 05/06/2005 14:30:00 1.8 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1.2 0.7 3 0.4 2 43 347 255 0 0 0 0 17.1 0 17.4 16.8 05/06/2005 14:40:00 2.7 0.7 4.6 0.4 2.5 0.8 4.2 0.7 2.2 0.8 3.8 0.4 305 13 266 255 0 0 0 0 17.1 0 17.4 16.8 05/06/2005 14:50:00 2.3 0.6 3.8 0.4 2 0.7 3.4 0.4 1.5 0.9 3.4 0.4 314 15 309 255 0 0 0 0 16.9 0 17.4 16.8 05/06/2005 15:00:00 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.6 0.5 2.6 0.4 316 53 256 255 0 0 0 0 17.3 0 17.7 17.1 05/06/2005 15:10:00 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 0.7 0.5 2.3 0.4 300 22 282 255 0 0 0 0 17.5 0.1 17.7 17.1 05/06/2005 15:20:00 1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 25 56 318 255 0 0 0 0 17.3 0 17.7 17.1 05/06/2005 15:30:00 1.5 0.7 3 0.4 1.2 0.7 3 0.4 1.1 0.6 2.3 0.4 68 26 79 255 0 0 0 0 17.5 0 17.7 17.4 05/06/2005 15:40:00 1 0.5 2.6 0.4 0.7 0.4 1.9 0.4 0.7 0.5 2.3 0.4 64 61 339 255 0 0 0 0 17.3 0 17.4 17.1 05/06/2005 15:50:00 1 0.5 2.6 0.4 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 300 30 282 255 0 0 0 0 17.7 0 18 17.4 05/06/2005 16:00:00 1.3 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 27 33 31 255 0 0 0 0 18.2 0 18.2 18 05/06/2005 16:10:00 1.5 0.6 3 0.4 1.2 0.7 3 0.4 1.1 0.7 3 0.4 52 30 46 255 0 0 0 0 18 0 18.2 17.7 05/06/2005 16:20:00 2.3 0.6 3.8 0.4 2.1 0.7 3.8 0.4 1.7 0.7 3.4 0.4 20 18 2 255 0 0 0 0 17.4 0 17.7 17.1 05/06/2005 16:30:00 2.4 0.6 4.2 1.1 2.2 0.6 3.8 1.1 1.9 0.6 3.4 0.4 40 18 20 255 0 0 0 0 17.4 0 17.4 17.1 05/06/2005 16:40:00 1.7 0.5 3 0.4 1.4 0.5 3 0.4 1.1 0.6 3 0.4 28 16 62 255 0 0 0 0 17.3 0 17.4 17.1 05/06/2005 16:50:00 2.5 0.6 4.2 1.1 2.3 0.7 4.2 0.7 1.9 0.7 3.8 0.4 48 19 48 255 0 0 0 0 17.2 0 17.4 16.8 05/06/2005 17:00:00 1.9 0.7 3.4 0.4 1.6 0.8 3 0.4 1.3 0.7 3 0.4 71 14 42 255 0 0 0 0 17.1 0 17.1 16.8 05/06/2005 17:10:00 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 47 30 19 255 0 0 0 0 17.1 0 17.1 16.8 05/06/2005 17:20:00 2 0.6 3 0.4 1.6 0.7 3 0.4 1 0.6 2.6 0.4 17 14 14 255 0 0 0 0 17.4 0 17.7 17.1 05/06/2005 17:30:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 1.1 0.7 2.6 0.4 39 38 10 255 0 0 0 0 17.7 0 18 17.4 05/06/2005 17:40:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 1.2 0.7 3 0.4 84 20 89 255 0 0 0 0 17.4 0 17.7 17.1 05/06/2005 17:50:00 2.2 0.6 3.8 0.7 2 0.6 3.4 0.4 1.7 0.6 3 0.4 36 38 19 255 0 0 0 0 17.5 0 17.7 17.4 05/06/2005 18:00:00 2 0.5 3 0.7 1.7 0.6 3 0.4 1.4 0.7 2.6 0.4 38 19 37 255 0 0 0 0 17.5 0 17.7 17.1 05/06/2005 18:10:00 1.7 0.6 3 0.4 1.4 0.7 3 0.4 1.1 0.6 2.6 0.4 64 23 51 255 0 0 0 0 17.3 0 17.4 17.1 05/06/2005 18:20:00 2 0.5 3 0.4 1.7 0.6 3 0.4 1.4 0.7 2.6 0.4 68 30 87 255 0 0 0 0 17.3 0 17.4 17.1 05/06/2005 18:30:00 1.5 0.5 3 0.4 1.2 0.6 3 0.4 1 0.6 2.3 0.4 54 21 75 255 0 0 0 0 17.3 0 17.4 17.1 05/06/2005 18:40:00 2.2 0.4 3.4 1.1 2 0.5 3 1.1 1.7 0.6 2.6 0.4 43 21 28 255 0 0 0 0 17.2 0 17.4 16.8 05/06/2005 18:50:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.6 0.4 62 11 51 255 0 0 0 0 17 0 17.1 16.8 05/06/2005 19:00:00 1.5 0.7 3 0.4 1.2 0.7 3 0.4 0.9 0.6 2.3 0.4 27 22 17 255 0 0 0 0 16.8 0 17.1 16.8 05/06/2005 19:10:00 1.4 0.5 2.6 0.4 1 0.6 2.6 0.4 0.5 0.4 1.9 0.4 13 12 56 255 0 0 0 0 16.7 0 17.1 16.6 05/06/2005 19:20:00 1.8 0.5 3 0.7 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 18 19 19 255 0 0 0 0 16.4 0.1 16.8 16.3 05/06/2005 19:30:00 1.8 0.6 2.6 0.4 1.4 0.7 2.6 0.4 0.8 0.5 2.3 0.4 352 11 356 255 0 0 0 0 16.1 0 16.8 16 05/06/2005 19:40:00 2.3 0.4 3.4 0.7 2.1 0.5 3.4 0.4 1.1 0.7 2.6 0.4 2 12 343 255 0 0 0 0 15.8 0 16.6 15.7 05/06/2005 19:50:00 3 0.5 4.2 1.5 2.8 0.6 4.2 1.5 1.6 0.8 3.4 0.4 0 13 3 255 0 0 0 0 15.9 0 16.3 15.7 05/06/2005 20:00:00 2.6 0.5 4.2 1.1 2.5 0.5 3.8 0.7 1.6 0.6 3 0.4 4 9 347 255 0 0 0 0 15.9 0 16.3 15.7 05/06/2005 20:10:00 1.8 0.5 3 0.7 1.4 0.6 3 0.4 0.9 0.5 1.9 0.4 3 9 7 255 0 0 0 0 15.6 0.1 16.3 15.2 05/06/2005 20:20:00 1.8 0.6 3 0.7 1.4 0.8 3 0.4 0.9 0.7 2.6 0.4 13 18 28 255 0 0 0 0 15 0 15.7 14.9 05/06/2005 20:30:00 2 0.5 3 0.7 1.7 0.6 3 0.4 0.8 0.5 2.3 0.4 4 12 34 255 0 0 0 0 14.6 0.2 15.2 14.1 05/06/2005 20:40:00 2.4 0.4 3.4 1.1 2.1 0.5 3 0.4 1 0.6 2.6 0.4 1 7 3 255 0 0 0 0 13.8 0.2 14.6 13.3 05/06/2005 20:50:00 2.3 0.4 3.4 1.1 2.1 0.5 3.4 1.1 1.2 0.6 2.6 0.4 18 8 10 255 0 0 0 0 13.2 0.2 13.8 12.7 05/06/2005 21:00:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 0.4 0.3 1.9 0.4 32 10 6 255 0 0 0 0 12.6 0.2 13.3 12.2 05/06/2005 21:10:00 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 343 9 337 255 0 0 0 0 12 0.1 12.2 11.7 05/06/2005 21:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 342 255 0 0 0 0 11.5 0.1 11.9 11.1 05/06/2005 21:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 308 15 324 255 0 0 0 0 10.9 0.2 11.7 10.6 05/06/2005 21:40:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 314 10 302 255 0 0 0 0 10.4 0.1 11.1 10.3 05/06/2005 21:50:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.3 1.9 0.4 279 7 264 255 0 0 0 0 10 0.1 10.3 9.6 05/06/2005 22:00:00 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 294 8 287 255 0 0 0 0 9.4 0 9.6 9.3 05/06/2005 22:10:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 315 9 311 255 0 0 0 0 9 0 9.3 8.8 05/06/2005 22:20:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 298 13 308 255 0 0 0 0 8.9 0 9.3 8.8 05/06/2005 22:30:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0 21 31 255 0 0 0 0 8.6 0.1 9 8.5 05/06/2005 22:40:00 1.3 0.2 1.9 0.7 0.8 0.2 1.5 0.4 0.4 0 0.7 0.4 1 3 1 255 0 0 0 0 8.2 0 8.5 8.3 05/06/2005 22:50:00 0.9 0.4 2.3 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 354 13 337 255 0 0 0 0 8 0 8.3 7.8 05/06/2005 23:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 310 17 289 255 0 0 0 0 7.8 0 7.8 7.5 05/06/2005 23:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 280 1 279 255 0 0 0 0 7.5 0.1 7.8 7.3 05/06/2005 23:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 281 255 0 0 0 0 7.2 0 7.3 7 05/06/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 255 255 0 0 0 0 6.9 0 7.3 6.7 05/06/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 282 10 255 255 0 0 0 0 6.6 0 7 6.2 05/06/2005 23:50:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 22 339 255 0 0 0 0 6.2 0 6.5 6 05/07/2005 00:00:00 0.9 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 31 1 30 255 0 0 0 0 6 0.1 6.2 5.7 05/07/2005 00:10:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 32 255 0 0 0 0 5.7 0 6 5.7 05/07/2005 00:20:00 1 0.2 1.5 0.4 0.5 0.2 0.7 0.4 0.4 0 0.4 0.4 33 2 32 255 0 0 0 0 5.6 0 5.7 5.5 05/07/2005 00:30:00 0.8 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 43 4 40 255 0 0 0 0 5.3 0 5.5 5.2 05/07/2005 00:40:00 0.9 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 48 0 49 255 0 0 0 0 5.1 0 5.2 5 05/07/2005 00:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 0 49 255 0 0 0 0 5 0 5 4.8 05/07/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 0 255 255 0 0 0 0 4.8 0.1 5 4.5 05/07/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 0 255 255 0 0 0 0 4.5 0 4.5 4.5 05/07/2005 01:20:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 48 0 49 255 0 0 0 0 4.4 0 4.5 4.3 05/07/2005 01:30:00 0.7 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 50 4 49 255 0 0 0 0 4.3 0 4.5 4.3 05/07/2005 01:40:00 1.2 0.2 1.9 0.7 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 73 0 73 255 0 0 0 0 4.1 0 4.5 3.8 05/07/2005 01:50:00 1.4 0.3 1.9 0.7 1 0.3 1.9 0.4 0.4 0 0.4 0.4 73 0 73 255 0 0 0 0 3.9 0 4 3.5 05/07/2005 02:00:00 1.2 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 81 4 82 255 0 0 0 0 3.8 0 3.8 3.8 05/07/2005 02:10:00 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 96 2 97 255 0 0 0 0 3.8 0 3.8 3.5 05/07/2005 02:20:00 1.3 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 106 1 102 255 0 0 0 0 3.5 0 3.8 3.3 05/07/2005 02:30:00 1.2 0.2 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 106 0 106 255 0 0 0 0 3.4 0 3.5 3.3 05/07/2005 02:40:00 1.3 0.3 1.9 0.7 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 106 0 106 255 0 0 0 0 3.3 0 3.5 3.3 05/07/2005 02:50:00 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 106 0 106 255 0 0 0 0 3.1 0 3.5 2.8 05/07/2005 03:00:00 1.7 0.2 2.3 1.1 1.4 0.3 1.9 0.7 0.6 0.3 1.5 0.4 111 4 115 255 0 0 0 0 3 0 3.5 2.8 05/07/2005 03:10:00 1.7 0.2 2.3 1.1 1.3 0.2 1.9 0.7 0.4 0.1 1.1 0.4 112 3 107 255 0 0 0 0 2.9 0 3.3 2.8 05/07/2005 03:20:00 1.4 0.3 1.9 0.7 1 0.3 1.5 0.4 0.4 0 0.7 0.4 111 0 112 255 0 0 0 0 2.9 0 3.3 2.8 05/07/2005 03:30:00 1.5 0.6 2.6 0.7 1.1 0.7 2.6 0.4 0.4 0.1 1.1 0.4 111 3 110 255 0 0 0 0 2.8 0 3.3 2.6 05/07/2005 03:40:00 1.9 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.5 0.3 1.9 0.4 111 6 116 255 0 0 0 0 2.6 0.1 2.8 2.3 05/07/2005 03:50:00 1.4 0.4 2.3 0.7 0.9 0.4 2.3 0.4 0.4 0 0.4 0.4 114 5 103 255 0 0 0 0 2.4 0 2.6 2.3 05/07/2005 04:00:00 1.6 0.5 2.6 0.7 1.3 0.6 2.6 0.4 0.4 0.2 1.1 0.4 110 6 113 255 0 0 0 0 2.4 0 2.8 2.3 05/07/2005 04:10:00 1.8 0.4 2.6 0.7 1.5 0.4 2.3 0.4 0.6 0.3 1.5 0.4 103 5 94 255 0 0 0 0 2.3 0 2.8 2.1 05/07/2005 04:20:00 1.9 0.3 2.6 1.1 1.6 0.3 2.3 0.7 0.7 0.3 1.5 0.4 86 5 87 255 0 0 0 0 2.1 0 2.6 1.8 05/07/2005 04:30:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 0.4 0.1 1.1 0.4 89 8 82 255 0 0 0 0 2.2 0 2.6 2.1 05/07/2005 04:40:00 1.6 0.3 2.6 0.7 1.3 0.4 2.3 0.4 0.4 0.1 1.1 0.4 85 4 81 255 0 0 0 0 2.2 0 2.6 2.1 05/07/2005 04:50:00 2.2 0.5 3.4 1.1 1.9 0.6 3.4 0.7 0.7 0.4 2.3 0.4 96 6 94 255 0 0 0 0 2.1 0 2.3 2.1 05/07/2005 05:00:00 2.3 0.3 3 1.5 2 0.3 2.6 1.1 0.8 0.3 1.5 0.4 104 5 118 255 0 0 0 0 2 0 2.3 1.8 05/07/2005 05:10:00 2.2 0.4 3 1.1 1.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 98 6 102 255 0 0 0 0 2.1 0 2.3 1.8 05/07/2005 05:20:00 1.2 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 119 8 101 255 0 0 0 0 2.3 0 2.6 2.1 05/07/2005 05:30:00 1.4 0.3 2.3 0.7 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 97 9 100 255 0 0 0 0 2.6 0 2.8 2.3 05/07/2005 05:40:00 1.4 0.3 2.3 0.7 1 0.3 1.9 0.4 0.4 0.1 0.7 0.4 79 5 74 255 0 0 0 0 2.8 0 3 2.8 05/07/2005 05:50:00 1.3 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 78 6 93 255 0 0 0 0 3.2 0.1 3.5 2.8 05/07/2005 06:00:00 1.6 0.2 2.3 0.7 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 104 9 89 255 0 0 0 0 3.7 0 4 3.5 05/07/2005 06:10:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 0.4 0.2 1.1 0.4 114 9 102 255 0 0 0 0 4.3 0.2 4.8 4 05/07/2005 06:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 143 6 93 255 0 0 0 0 5.2 0.4 5.7 4.5 05/07/2005 06:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 131 13 127 255 0 0 0 0 6.2 0.2 6.7 5.7 05/07/2005 06:40:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 117 7 128 255 0 0 0 0 7.3 0.3 8 6.7 05/07/2005 06:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 0 115 255 0 0 0 0 8.6 0.4 9.3 7.8 05/07/2005 07:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 114 0 115 255 0 0 0 0 9.6 0.1 9.8 9.3 05/07/2005 07:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 74 32 98 255 0 0 0 0 10.3 0.3 10.6 9.8 05/07/2005 07:20:00 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 0.9 0.6 2.3 0.4 35 22 30 255 0 0 0 0 11.1 0 11.7 10.6 05/07/2005 07:30:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.1 0.6 2.6 0.4 29 11 26 255 0 0 0 0 11.3 0 11.9 11.1 05/07/2005 07:40:00 1.5 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 36 13 24 255 0 0 0 0 11.7 0.1 12.2 11.4 05/07/2005 07:50:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.2 0.6 2.6 0.4 23 11 10 255 0 0 0 0 12.1 0 12.7 11.9 05/07/2005 08:00:00 1.4 0.4 2.6 0.4 1.1 0.4 2.3 0.4 0.8 0.5 2.3 0.4 20 16 23 255 0 0 0 0 12.5 0.1 13 12.2 05/07/2005 08:10:00 1.3 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 15 22 14 255 0 0 0 0 13 0.1 13.5 12.7 05/07/2005 08:20:00 1.8 0.5 3.4 0.4 1.6 0.6 3.4 0.4 1.3 0.6 2.6 0.4 32 13 2 255 0 0 0 0 13.2 0.2 13.5 12.7 05/07/2005 08:30:00 1.6 0.4 3 0.7 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 19 20 11 255 0 0 0 0 13.9 0.3 14.6 13.3 05/07/2005 08:40:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.8 0.5 2.3 0.4 12 27 40 255 0 0 0 0 14.3 0 14.9 14.4 05/07/2005 08:50:00 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 351 18 347 255 0 0 0 0 14.4 0 14.9 14.4 05/07/2005 09:00:00 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 15 32 30 255 0 0 0 0 14.7 0 15.2 14.6 05/07/2005 09:10:00 1.9 0.5 3.4 0.7 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 356 17 3 255 0 0 0 0 14.9 0 15.2 14.6 05/07/2005 09:20:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 0.7 1.8 0.6 3 0.4 1 12 339 255 0 0 0 0 15.3 0 15.7 15.2 05/07/2005 09:30:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.7 0.6 3.4 0.4 358 13 345 255 0 0 0 0 15.5 0 16 15.5 05/07/2005 09:40:00 2.2 0.5 3.4 1.1 1.9 0.5 3 0.7 1.7 0.6 2.6 0.4 356 17 1 255 0 0 0 0 15.5 0 16 15.2 05/07/2005 09:50:00 2 0.5 3.4 0.4 1.7 0.6 3.4 0.4 1.4 0.6 2.6 0.4 9 18 2 255 0 0 0 0 16.1 0.1 16.6 15.7 05/07/2005 10:00:00 1.6 0.7 3 0.4 1.4 0.8 3 0.4 1.3 0.7 3.4 0.4 309 38 343 255 0 0 0 0 16 0 16.3 15.7 05/07/2005 10:10:00 2.4 0.6 3.8 0.4 2.1 0.7 3.8 0.4 1.6 0.8 3.8 0.4 336 33 327 255 0 0 0 0 16.4 0.2 16.8 16 05/07/2005 10:20:00 2.2 0.7 4.2 0.4 2 0.8 3.8 0.4 1.7 0.8 4.2 0.4 277 28 292 255 0 0 0 0 16.2 0.2 16.8 15.7 05/07/2005 10:30:00 2.4 0.6 4.6 0.7 2.1 0.7 4.2 0.4 1.8 0.7 3.4 0.4 284 28 287 255 0 0 0 0 16.8 0 17.1 16.6 05/07/2005 10:40:00 1.7 0.9 4.2 0.4 1.5 1 3.8 0.4 1.1 0.8 3.4 0.4 282 33 255 255 0 0 0 0 17.1 0.2 17.7 16.8 05/07/2005 10:50:00 1.7 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.1 0.8 3 0.4 311 38 289 255 0 0 0 0 17.9 0.3 18.8 17.4 05/07/2005 11:00:00 2.1 0.8 3.8 0.4 1.8 0.8 4.2 0.4 1.5 0.8 4.2 0.4 344 23 350 255 0 0 0 0 18.7 0 19.1 18.2 05/07/2005 11:10:00 1.6 0.8 3.8 0.4 1.3 0.8 3 0.4 1.1 0.6 3 0.4 336 22 347 255 0 0 0 0 18.2 0 18.8 18 05/07/2005 11:20:00 1.4 0.8 3.4 0.4 1.2 0.9 3.4 0.4 1.1 0.8 3.4 0.4 228 102 301 255 0 0 0 0 18.1 0.1 18.5 17.7 05/07/2005 11:30:00 2 0.9 4.2 0.4 1.7 1 3.8 0.4 1.4 0.9 3.8 0.4 9 61 324 255 0 0 0 0 18.5 0.2 19.1 18 05/07/2005 11:40:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 1.4 0.8 3.8 0.4 317 26 325 255 0 0 0 0 18.6 0.1 19.4 18.2 05/07/2005 11:50:00 2.8 0.9 4.9 0.4 2.3 0.9 4.2 0.4 2 1 4.2 0.4 333 32 339 255 0 0 0 0 19.3 0.2 20 18.8 05/07/2005 12:00:00 2 1.1 5.7 0.4 1.7 1.1 6.1 0.4 1.2 1 4.2 0.4 300 53 329 255 0 0 0 0 19.6 0.1 20 19.4 05/07/2005 12:10:00 2.7 0.9 4.9 0.7 2.5 1 4.6 0.4 2.2 0.9 4.6 0.4 327 35 308 255 0 0 0 0 19.5 0.1 20 19.4 05/07/2005 12:20:00 2.9 0.5 3.8 1.5 2.6 0.6 3.8 1.1 2.3 0.6 3.8 0.7 354 16 12 255 0 0 0 0 19.5 0.1 20.3 19.1 05/07/2005 12:30:00 2.3 0.8 4.6 0.4 2 0.9 4.9 0.4 1.8 0.9 3.8 0.4 312 38 308 255 0 0 0 0 19.8 0.1 20.3 19.4 05/07/2005 12:40:00 2.1 1.2 5.3 0.4 1.9 1.2 5.3 0.4 1.4 1.1 4.6 0.4 305 58 317 255 0 0 0 0 19.9 0.3 20.5 19.4 05/07/2005 12:50:00 3 1 5.3 0.4 2.7 1.1 5.3 0.4 2.3 1.2 5.3 0.4 315 22 345 255 0 0 0 0 20.5 0 21.1 20.3 05/07/2005 13:00:00 2 1 4.2 0.4 1.7 1 4.2 0.4 1.6 1 3.8 0.4 331 26 277 255 0 0 0 0 20.5 0.1 21.1 20.3 05/07/2005 13:10:00 1.9 0.9 4.2 0.4 1.7 1 3.8 0.4 1.3 0.9 3.8 0.4 312 45 9 255 0 0 0 0 20.3 0.1 20.8 20 05/07/2005 13:20:00 2.7 0.9 4.6 0.7 2.5 1 4.6 0.4 2.1 1.1 4.6 0.4 309 28 317 255 0 0 0 0 20.9 0.2 21.4 20.5 05/07/2005 13:30:00 2.6 1 6.1 0.4 2.3 1 5.7 0.4 2 0.9 4.6 0.4 356 36 325 255 0 0 0 0 20.7 0.1 21.1 20.5 05/07/2005 13:40:00 2 0.7 3.8 0.7 1.7 0.7 3.4 0.4 1.4 0.7 3 0.4 13 56 3 255 0 0 0 0 21 0.1 21.4 20.5 05/07/2005 13:50:00 1.7 0.9 4.2 0.4 1.5 1 4.6 0.4 1.2 0.8 4.9 0.4 300 90 248 255 0 0 0 0 21 0.2 21.7 20.5 05/07/2005 14:00:00 2 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 312 47 329 255 0 0 0 0 21.9 0 22.9 21.7 05/07/2005 14:10:00 2.8 1 4.9 0.7 2.5 1 4.6 0.4 2 1.1 4.6 0.4 326 35 256 255 0 0 0 0 22.4 0 23.2 22.3 05/07/2005 14:20:00 1.7 0.9 3.8 0.4 1.5 1 3.8 0.4 1.2 0.8 3.8 0.4 355 64 8 255 0 0 0 0 21.7 0.2 22.3 21.4 05/07/2005 14:30:00 2.6 1.2 4.9 0.4 2.4 1.3 5.3 0.4 1.5 1 4.6 0.4 10 56 20 255 0 0 0 0 22.2 0.5 23.2 21.7 05/07/2005 14:40:00 1.7 0.8 4.6 0.4 1.5 0.8 4.2 0.4 1 0.6 3.8 0.4 22 49 302 255 0 0 0 0 22.5 0.4 23.2 21.7 05/07/2005 14:50:00 1.7 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.1 0.8 3.4 0.4 32 76 4 255 0 0 0 0 21.6 0.1 22 21.1 05/07/2005 15:00:00 3.4 1.2 6.5 0.4 3 1.2 6.1 0.4 2.5 1.5 5.3 0.4 338 23 315 255 0 0 0 0 21.9 0 22 21.7 05/07/2005 15:10:00 1.6 0.9 4.6 0.4 1.3 1 4.2 0.4 0.9 0.7 3.4 0.4 14 61 16 255 0 0 0 0 22.1 0.1 22.9 22 05/07/2005 15:20:00 2.7 1 5.3 0.4 2.4 1 4.6 0.4 1.8 1.1 4.2 0.4 7 28 331 255 0 0 0 0 23.3 0.1 23.5 22.9 05/07/2005 15:30:00 2.8 1.1 4.9 0.4 2.5 1.1 4.9 0.4 2.2 1.1 4.6 0.4 338 29 322 255 0 0 0 0 22.2 0 23.2 22 05/07/2005 15:40:00 1.9 1 4.6 0.4 1.7 1 4.6 0.4 1.5 0.8 3.8 0.4 247 90 298 255 0 0 0 0 21.7 0.3 22.3 21.1 05/07/2005 15:50:00 2.9 0.8 5.3 0.4 2.8 0.9 5.3 0.4 2.5 1 5.3 0.4 262 22 254 255 0 0 0 0 21.2 0 21.7 20.8 05/07/2005 16:00:00 2.2 1 4.9 0.4 1.9 1.1 4.6 0.4 1.5 1.1 4.6 0.4 256 29 316 255 0 0 0 0 21.9 0.2 22.3 21.4 05/07/2005 16:10:00 1.4 0.8 3.4 0.4 1.1 0.8 3.4 0.4 0.9 0.7 3 0.4 282 38 286 255 0 0 0 0 21.6 0 21.7 21.4 05/07/2005 16:20:00 1.8 0.8 4.2 0.4 1.5 0.9 3.4 0.4 1.3 0.9 3.8 0.4 351 35 309 255 0 0 0 0 21.3 0.1 22 21.1 05/07/2005 16:30:00 1.8 0.7 3.8 0.4 1.5 0.8 3.8 0.4 1.2 0.9 3.4 0.4 7 41 0 255 0 0 0 0 21.4 0 21.7 21.1 05/07/2005 16:40:00 2 1 4.6 0.4 1.8 1 4.6 0.4 1.7 0.8 4.2 0.4 8 45 15 255 0 0 0 0 21.1 0 21.7 21.1 05/07/2005 16:50:00 2.5 1 4.9 0.4 2.3 1 4.9 0.4 1.9 1 4.2 0.4 276 27 330 255 0 0 0 0 21 0 21.1 20.8 05/07/2005 17:00:00 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 13 43 354 255 0 0 0 0 21 0 21.1 20.8 05/07/2005 17:10:00 1.9 0.8 4.2 0.4 1.7 0.9 3.8 0.4 1.1 0.7 3 0.4 27 27 52 255 0 0 0 0 20.9 0 21.4 20.8 05/07/2005 17:20:00 2.8 0.9 4.9 0.7 2.6 1 4.6 0.7 2.1 1 4.2 0.4 308 61 294 255 0 0 0 0 20.9 0.1 21.4 20.8 05/07/2005 17:30:00 3.9 0.8 6.5 1.9 3.8 0.8 6.5 1.9 3 1 4.9 0.4 12 12 16 255 0 0 0 0 20.7 0 21.1 20.5 05/07/2005 17:40:00 4.4 1.4 6.8 1.1 4.3 1.5 6.8 0.7 3.1 1.5 6.5 0.4 12 17 18 255 0 0 0 0 20.8 0.1 21.1 20.5 05/07/2005 17:50:00 5 0.7 6.5 2.3 4.9 0.7 6.1 2.3 3.8 1 6.1 1.9 20 11 7 255 0 0 0 0 20.6 0.1 21.1 20.5 05/07/2005 18:00:00 4.5 0.8 6.1 1.9 4.3 0.8 6.1 1.9 3.8 0.8 6.1 1.9 27 10 25 255 0 0 0 0 20.5 0 21.1 20.3 05/07/2005 18:10:00 5 0.8 7.6 3 5 0.8 7.6 3 4.1 0.8 6.1 1.5 20 8 38 255 0 0 0 0 20.3 0.1 20.8 20 05/07/2005 18:20:00 4.3 1 6.5 1.5 4.1 1.1 6.5 1.1 3.3 1.3 5.7 0.4 12 18 20 255 0 0 0 0 19.9 0.1 20.5 19.4 05/07/2005 18:30:00 4 0.9 6.5 1.9 3.9 1 6.1 1.1 2.7 1.2 5.3 0.4 13 15 21 255 0 0 0 0 19.5 0 20 19.4 05/07/2005 18:40:00 3.1 1.4 6.5 0.4 2.9 1.5 6.5 0.4 2.3 1.2 5.3 0.4 347 29 20 255 0 0 0 0 19.3 0 19.4 19.1 05/07/2005 18:50:00 2 0.7 3.4 0.4 1.8 0.8 3.4 0.4 1.6 0.8 3.4 0.4 272 58 294 255 0 0 0 0 19 0 19.1 18.8 05/07/2005 19:00:00 2.2 0.8 4.2 0.7 2 1 4.6 0.4 1.4 0.8 3.4 0.4 272 20 237 255 0 0 0 0 18.5 0.1 18.8 18 05/07/2005 19:10:00 3 0.9 5.7 1.1 2.9 1 6.1 1.1 2.1 1 4.9 0.4 266 17 264 255 0 0 0 0 17.8 0 18.2 17.7 05/07/2005 19:20:00 2.1 0.9 3.8 0.4 1.8 1 3.8 0.4 1.2 0.9 3.4 0.4 273 15 293 255 0 0 0 0 17.5 0.1 17.7 17.1 05/07/2005 19:30:00 1.3 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.5 0.3 1.9 0.4 274 17 277 255 0 0 0 0 16.8 0.2 17.1 16.6 05/07/2005 19:40:00 2 0.9 4.9 0.4 1.7 1 4.9 0.4 1.3 0.9 3.8 0.4 273 22 276 255 0 0 0 0 16.2 0 16.8 16.3 05/07/2005 19:50:00 1.7 0.9 3.4 0.4 1.4 0.8 3 0.4 0.9 0.6 2.6 0.4 264 13 255 255 0 0 0 0 15.9 0.1 16.6 15.7 05/07/2005 20:00:00 1.3 0.7 3 0.4 1 0.6 2.6 0.4 0.6 0.5 1.9 0.4 250 15 255 255 0 0 0 0 15.7 0 16.3 15.5 05/07/2005 20:10:00 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 266 38 255 255 0 0 0 0 15.2 0.2 16 14.9 05/07/2005 20:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 340 22 5 255 0 0 0 0 14.4 0.2 14.9 13.8 05/07/2005 20:30:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 1 8 17 255 0 0 0 0 13.7 0.2 14.6 13.3 05/07/2005 20:40:00 2.1 0.6 3.8 1.1 1.7 0.6 3.4 0.4 0.9 0.7 3 0.4 358 13 332 255 0 0 0 0 13 0.2 13.5 12.5 05/07/2005 20:50:00 2.2 0.6 3.8 0.7 1.8 0.7 3.8 0.4 1 0.7 3 0.4 343 21 311 255 0 0 0 0 12.6 0.1 13 12.2 05/07/2005 21:00:00 2.4 0.6 3.8 1.1 2.1 0.7 4.2 0.4 1.5 0.8 4.2 0.4 339 21 308 255 0 0 0 0 12.5 0.2 13 12.2 05/07/2005 21:10:00 2 0.5 3.4 1.1 1.5 0.6 3 0.4 0.8 0.5 2.3 0.4 338 12 329 255 0 0 0 0 12.1 0.2 12.7 11.7 05/07/2005 21:20:00 2.4 0.4 3.4 1.5 1.8 0.6 3 0.7 1.1 0.6 2.6 0.4 328 7 321 255 0 0 0 0 11.5 0.1 11.9 11.1 05/07/2005 21:30:00 2.9 0.5 4.2 1.5 2.6 0.6 3.8 1.1 1.3 0.7 3 0.4 320 8 308 255 0 0 0 0 10.9 0.2 11.7 10.6 05/07/2005 21:40:00 2.9 0.4 4.2 1.9 2.6 0.5 3.8 1.5 1.2 0.6 2.6 0.4 308 10 312 255 0 0 0 0 10.5 0 10.9 10.3 05/07/2005 21:50:00 2.5 0.4 3.8 1.5 2.3 0.5 3.4 1.1 1.1 0.6 2.6 0.4 301 10 294 255 0 0 0 0 10.1 0 10.6 10.1 05/07/2005 22:00:00 2 0.5 3.4 0.4 1.7 0.6 3 0.4 0.7 0.5 2.6 0.4 284 11 290 255 0 0 0 0 9.8 0.1 10.6 9.6 05/07/2005 22:10:00 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.5 0.3 1.5 0.4 271 9 266 255 0 0 0 0 9.5 0 9.8 9.3 05/07/2005 22:20:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 246 16 266 255 0 0 0 0 9.2 0.1 9.8 9 05/07/2005 22:30:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 198 10 184 255 0 0 0 0 8.9 0.1 9.6 8.5 05/07/2005 22:40:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 210 1 212 255 0 0 0 0 8.5 0.1 9 8.3 05/07/2005 22:50:00 1.1 0.5 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 298 98 48 255 0 0 0 0 8 0.2 8.8 7.8 05/07/2005 23:00:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 30 13 20 255 0 0 0 0 7.6 0.1 7.8 7.5 05/07/2005 23:10:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 10 10 4 255 0 0 0 0 7.5 0.1 8 7.3 05/07/2005 23:20:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 30 0 30 255 0 0 0 0 7.3 0 7.8 7.3 05/07/2005 23:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 30 255 0 0 0 0 7.3 0 7.8 7.3 05/07/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 255 255 0 0 0 0 7 0.1 7.5 7 05/07/2005 23:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 30 255 0 0 0 0 6.7 0 7.3 6.5 05/08/2005 00:00:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 30 0 30 255 0 0 0 0 6.5 0 6.7 6.5 05/08/2005 00:10:00 1.8 0.7 3.4 0.4 1.5 0.8 3 0.4 0.6 0.4 1.9 0.4 250 33 235 255 0 0 0 0 6.4 0 6.7 6.2 05/08/2005 00:20:00 2.1 0.7 3.8 0.4 1.9 0.8 3.8 0.4 0.9 0.5 2.6 0.4 243 11 255 255 0 0 0 0 6.2 0 6.2 6 05/08/2005 00:30:00 2.5 0.7 4.6 1.1 2.4 0.8 4.9 0.7 1.5 0.8 3.4 0.4 244 15 230 255 0 0 0 0 6.3 0.1 6.7 6 05/08/2005 00:40:00 2.5 0.7 4.6 0.7 2.2 0.7 4.2 0.4 1.2 0.7 3 0.4 238 13 243 255 0 0 0 0 6.6 0 6.7 6.5 05/08/2005 00:50:00 2.1 0.3 3.4 1.5 1.9 0.4 3 1.1 0.8 0.4 1.9 0.4 225 9 243 255 0 0 0 0 6.6 0 6.7 6.5 05/08/2005 01:00:00 2.3 0.4 3.4 1.5 2.1 0.4 3.4 1.1 0.9 0.4 1.9 0.4 214 5 232 255 0 0 0 0 6.3 0 6.7 6.2 05/08/2005 01:10:00 2.5 0.4 3.4 1.9 2.4 0.4 3.4 1.5 1.4 0.5 2.3 0.4 207 5 211 255 0 0 0 0 6 0 6.2 5.7 05/08/2005 01:20:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.3 0.5 2.6 0.4 210 8 209 255 0 0 0 0 5.7 0.1 6 5.5 05/08/2005 01:30:00 2.1 0.4 3 1.1 1.9 0.4 3 0.7 0.8 0.4 1.9 0.4 213 14 232 255 0 0 0 0 5.1 0.1 5.5 4.8 05/08/2005 01:40:00 2.1 0.4 3.4 1.1 2.2 0.4 3 1.1 1.3 0.4 2.6 0.4 168 9 161 255 0 0 0 0 4.6 0 4.8 4.3 05/08/2005 01:50:00 1.5 0.3 2.3 0.7 1.8 0.4 2.6 0.7 0.8 0.5 2.3 0.4 177 4 171 255 0 0 0 0 4.3 0.1 4.5 4 05/08/2005 02:00:00 1.2 0.3 1.9 0.4 1.3 0.5 2.6 0.4 0.4 0.2 1.5 0.4 178 2 180 255 0 0 0 0 4 0 4 4 05/08/2005 02:10:00 1.9 0.3 2.6 1.1 2.2 0.3 2.6 1.1 1.4 0.4 2.3 0.4 180 6 175 255 0 0 0 0 4 0 4.3 4 05/08/2005 02:20:00 1.9 0.3 3 1.1 2.4 0.3 3 1.5 1.6 0.4 2.6 0.4 173 5 179 255 0 0 0 0 4 0 4.3 3.8 05/08/2005 02:30:00 2.3 0.4 3 1.1 2.4 0.2 2.6 1.9 1.3 0.4 2.3 0.4 164 4 160 255 0 0 0 0 3.7 0.1 4 3.5 05/08/2005 02:40:00 2.5 0.3 3 1.5 2.4 0.3 3 1.5 1.3 0.3 1.9 0.7 159 2 160 255 0 0 0 0 3.3 0 3.5 3.3 05/08/2005 02:50:00 2.7 0.3 3 1.9 2.5 0.3 3 1.5 1.7 0.5 3 0.7 152 3 158 255 0 0 0 0 3.2 0 3.5 3.3 05/08/2005 03:00:00 2.5 0.3 3 1.9 2.3 0.3 3 1.5 1.2 0.6 2.6 0.4 146 8 149 255 0 0 0 0 2.9 0 3.3 2.8 05/08/2005 03:10:00 2.2 0.3 3 1.1 2.1 0.3 2.6 1.1 0.6 0.3 1.9 0.4 134 5 134 255 0 0 0 0 2.7 0 2.8 2.6 05/08/2005 03:20:00 2.1 0.3 2.6 1.5 1.8 0.4 2.6 0.7 0.8 0.4 1.5 0.4 139 4 142 255 0 0 0 0 2.4 0 2.8 2.3 05/08/2005 03:30:00 2.5 0.2 2.6 1.9 2.3 0.2 2.6 1.5 1.1 0.4 1.9 0.4 138 2 140 255 0 0 0 0 2.2 0 2.6 1.8 05/08/2005 03:40:00 2.5 0.2 2.6 2.3 2.3 0.2 2.6 1.9 1.4 0.4 2.3 0.4 146 1 143 255 0 0 0 0 1.8 0 2.1 1.8 05/08/2005 03:50:00 2.4 0.3 3 1.9 2.2 0.3 2.6 1.5 1 0.3 1.5 0.4 144 3 142 255 0 0 0 0 1.8 0 2.1 1.8 05/08/2005 04:00:00 2.5 0.2 3 1.9 2.3 0.2 2.6 1.5 1.1 0.4 1.9 0.4 138 2 138 255 0 0 0 0 1.8 0 2.1 1.8 05/08/2005 04:10:00 2.8 0.2 3 1.9 2.6 0.2 3 2.3 1.6 0.4 2.3 0.4 141 2 138 255 0 0 0 0 1.5 0.2 1.8 1.4 05/08/2005 04:20:00 2.4 0.4 3 1.1 2.2 0.4 3 0.7 1.1 0.4 1.9 0.4 137 4 138 255 0 0 0 0 1.4 0 1.6 1.4 05/08/2005 04:30:00 2.4 0.3 3 1.5 2.2 0.4 3 1.1 1.6 0.5 2.3 0.4 140 3 138 255 0 0 0 0 1.2 0 1.4 1.1 05/08/2005 04:40:00 2.1 0.4 3 1.1 1.9 0.4 2.6 0.7 1.1 0.4 2.3 0.4 141 7 146 255 0 0 0 0 1.1 0 1.4 0.9 05/08/2005 04:50:00 2.3 0.4 3.4 1.5 2.1 0.4 3 1.1 1.3 0.5 2.6 0.4 140 6 136 255 0 0 0 0 1.2 0 1.4 1.1 05/08/2005 05:00:00 1.9 0.4 3 1.1 1.7 0.5 3 0.4 0.8 0.5 2.3 0.4 127 9 137 255 0 0 0 0 1.2 0 1.4 1.4 05/08/2005 05:10:00 2.3 0.4 3 1.1 2 0.4 2.6 0.7 0.6 0.3 1.5 0.4 106 5 102 255 0 0 0 0 1.5 0 1.6 1.4 05/08/2005 05:20:00 1.6 0.7 3 0.4 1.2 0.7 2.6 0.4 0.5 0.3 1.9 0.4 102 5 109 255 0 0 0 0 1.6 0 1.6 1.6 05/08/2005 05:30:00 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 95 0 95 255 0 0 0 0 1.6 0 1.6 1.6 05/08/2005 05:40:00 1.6 0.3 2.6 0.7 1.2 0.4 2.3 0.4 0.4 0.2 1.5 0.4 100 7 107 255 0 0 0 0 1.7 0 1.8 1.6 05/08/2005 05:50:00 2.2 0.3 3 1.1 2 0.3 2.6 1.1 0.9 0.5 1.9 0.4 109 7 100 255 0 0 0 0 2.1 0.2 2.6 1.8 05/08/2005 06:00:00 2.4 0.3 3.4 1.5 2.2 0.3 3 1.1 1.2 0.5 2.6 0.4 102 8 89 255 0 0 0 0 2.5 0.1 2.8 2.3 05/08/2005 06:10:00 2.3 0.4 3.4 1.5 2.1 0.4 3 1.1 1.2 0.5 2.6 0.4 102 8 90 255 0 0 0 0 2.7 0 3 2.6 05/08/2005 06:20:00 2.8 0.5 3.8 1.5 2.6 0.6 4.2 0.7 1.4 0.6 3 0.4 97 9 94 255 0 0 0 0 4.1 0.7 5.2 2.8 05/08/2005 06:30:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.6 0.4 1.9 0.4 100 10 84 255 0 0 0 0 6.3 0.6 7.3 5 05/08/2005 06:40:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 99 11 109 255 0 0 0 0 7.7 0.2 8.3 7.3 05/08/2005 06:50:00 1.2 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.6 0.5 2.6 0.4 73 11 80 255 0 0 0 0 9.1 0.4 9.8 8.3 05/08/2005 07:00:00 1.6 0.6 2.6 0.4 1.3 0.7 2.6 0.4 1 0.6 2.3 0.4 84 13 77 255 0 0 0 0 10 0.2 10.3 9.8 05/08/2005 07:10:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.3 1.5 0.4 62 13 61 255 0 0 0 0 10.5 0.2 11.1 10.3 05/08/2005 07:20:00 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 22 22 15 255 0 0 0 0 11.1 0.3 11.9 10.6 05/08/2005 07:30:00 1.5 0.4 2.6 0.4 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 37 11 29 255 0 0 0 0 11.6 0 11.9 11.4 05/08/2005 07:40:00 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1 0.5 2.3 0.4 22 9 13 255 0 0 0 0 11.8 0.2 12.2 11.4 05/08/2005 07:50:00 1.7 0.4 2.6 0.7 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 16 13 30 255 0 0 0 0 12.3 0.1 12.7 12.2 05/08/2005 08:00:00 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.8 0.4 2.3 0.4 19 18 356 255 0 0 0 0 12.7 0 13 12.5 05/08/2005 08:10:00 1.6 0.4 3 0.7 1.3 0.4 2.6 0.4 1.1 0.5 2.3 0.4 20 9 22 255 0 0 0 0 13.1 0 13.3 12.7 05/08/2005 08:20:00 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 28 13 49 255 0 0 0 0 13.4 0 13.8 13.3 05/08/2005 08:30:00 1.4 0.5 2.6 0.7 1.1 0.6 2.6 0.4 0.9 0.4 2.3 0.4 13 15 7 255 0 0 0 0 13.9 0.1 14.4 13.3 05/08/2005 08:40:00 1.2 0.5 2.6 0.4 0.8 0.4 2.3 0.4 0.7 0.4 1.9 0.4 20 33 61 255 0 0 0 0 13.9 0 14.4 13.8 05/08/2005 08:50:00 0.9 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.5 0.3 1.9 0.4 356 24 6 255 0 0 0 0 14.2 0.2 14.9 13.8 05/08/2005 09:00:00 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 20 22 37 255 0 0 0 0 14.6 0.1 15.2 14.4 05/08/2005 09:10:00 1.2 0.6 3 0.4 1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 4 22 5 255 0 0 0 0 15 0.1 15.5 14.6 05/08/2005 09:20:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 28 12 14 255 0 0 0 0 15 0 15.5 14.9 05/08/2005 09:30:00 1 0.6 2.6 0.4 0.8 0.5 2.6 0.4 0.7 0.5 2.3 0.4 97 39 63 255 0 0 0 0 15.2 0.1 15.7 15.2 05/08/2005 09:40:00 1.1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 20 29 7 255 0 0 0 0 15.7 0 16 15.5 05/08/2005 09:50:00 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.6 2.6 0.4 32 26 37 255 0 0 0 0 16.2 0.1 16.6 16 05/08/2005 10:00:00 1.2 0.6 2.6 0.4 1 0.6 3 0.4 0.8 0.5 2.3 0.4 13 30 33 255 0 0 0 0 16.4 0 16.8 16.3 05/08/2005 10:10:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 31 39 342 255 0 0 0 0 16.6 0 16.8 16.3 05/08/2005 10:20:00 1.6 0.5 3 0.4 1.3 0.5 3 0.4 1 0.5 2.6 0.4 27 36 74 255 0 0 0 0 16.9 0.1 17.4 16.6 05/08/2005 10:30:00 1.5 0.6 3 0.4 1.2 0.6 3 0.4 1 0.6 3 0.4 24 38 26 255 0 0 0 0 17.4 0.2 18 16.8 05/08/2005 10:40:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 1 0.5 2.3 0.4 9 30 7 255 0 0 0 0 17.9 0.1 18.5 17.7 05/08/2005 10:50:00 1.2 0.7 3.4 0.4 1 0.7 3 0.4 0.9 0.6 2.6 0.4 304 53 291 255 0 0 0 0 18.5 0.2 19.1 18.2 05/08/2005 11:00:00 1.1 0.6 3 0.4 0.8 0.6 3 0.4 0.9 0.6 3.4 0.4 109 86 148 255 0 0 0 0 18.5 0.4 19.4 17.7 05/08/2005 11:10:00 1.4 0.6 2.6 0.4 1.2 0.7 3.4 0.4 1 0.6 2.6 0.4 85 94 194 255 0 0 0 0 18.1 0.4 19.4 17.7 05/08/2005 11:20:00 1.7 0.7 4.2 0.4 1.5 0.8 3.8 0.4 1.1 0.6 3 0.4 294 49 291 255 0 0 0 0 19.2 0 19.7 18.8 05/08/2005 11:30:00 1.9 1 4.2 0.4 1.8 1 4.2 0.4 1.4 0.8 3.8 0.4 252 53 223 255 0 0 0 0 19.3 0.1 20 18.8 05/08/2005 11:40:00 2.5 0.8 4.2 0.4 2.2 1 4.2 0.4 1.7 1.1 4.2 0.4 275 53 257 255 0 0 0 0 19.2 0.1 19.7 18.8 05/08/2005 11:50:00 2.4 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.9 0.9 3.8 0.4 311 33 314 255 0 0 0 0 19.1 0.2 19.7 18.5 05/08/2005 12:00:00 1.9 1 4.2 0.4 1.6 1 4.2 0.4 1.4 1 3.8 0.4 308 47 261 255 0 0 0 0 19.5 0 20 19.1 05/08/2005 12:10:00 2.4 1.1 4.9 0.4 2.2 1.2 4.6 0.4 1.7 1.3 4.6 0.4 273 39 265 255 0 0 0 0 20.1 0.1 20.5 19.7 05/08/2005 12:20:00 3.4 1.4 6.5 0.4 3.3 1.5 6.5 0.4 2.6 1.5 6.1 0.4 301 32 289 255 0 0 0 0 20 0.3 20.5 19.1 05/08/2005 12:30:00 3.6 1.2 6.8 0.7 3.4 1.3 6.8 0.4 2.9 1.3 5.7 0.4 308 29 326 255 0 0 0 0 19.7 0.2 20.3 19.1 05/08/2005 12:40:00 2.9 1 5.3 0.4 2.7 1.1 5.7 0.4 2.4 1.1 4.9 0.4 274 35 274 255 0 0 0 0 20.2 0 20.5 20 05/08/2005 12:50:00 4.3 1.2 7.2 1.5 4.2 1.3 7.2 0.7 3.4 1.5 7.2 0.4 284 27 302 255 0 0 0 0 20.4 0 20.5 20 05/08/2005 13:00:00 3.3 1.3 6.5 0.4 3.1 1.3 6.5 0.4 2.5 1.3 5.7 0.4 300 32 299 255 0 0 0 0 20.5 0.2 21.1 20.3 05/08/2005 13:10:00 4.5 1.1 7.2 1.5 4.4 1.2 7.6 1.5 3.7 1.2 6.8 0.4 302 21 310 255 0 0 0 0 20.4 0.2 21.1 20.3 05/08/2005 13:20:00 3.5 1.2 6.8 0.7 3.3 1.3 7.2 0.7 2.7 1.2 6.8 0.4 293 29 255 255 0 0 0 0 20.3 0 20.5 20.3 05/08/2005 13:30:00 4.3 1.3 7.2 1.1 4.1 1.4 7.6 0.7 3.4 1.5 7.2 0.4 298 22 297 255 0 0 0 0 20 0 20.8 19.7 05/08/2005 13:40:00 3.9 1.3 6.8 0.4 3.7 1.3 6.8 0.4 3.2 1.6 6.8 0.4 298 24 312 255 0 0 0 0 20.5 0.2 21.1 20 05/08/2005 13:50:00 4.1 1.2 6.8 1.1 3.9 1.2 6.8 0.7 3.5 1.2 6.1 0.7 304 20 278 255 0 0 0 0 20.4 0 20.5 20.3 05/08/2005 14:00:00 3.7 1 6.5 1.5 3.5 1.1 6.5 1.1 2.7 1.1 5.3 0.4 294 27 223 255 0 0 0 0 21 0.1 21.4 20.5 05/08/2005 14:10:00 3.6 1.3 6.1 0.4 3.4 1.3 6.5 0.4 3 1.3 5.7 0.4 294 22 299 255 0 0 0 0 20.8 0.1 21.1 20.5 05/08/2005 14:20:00 3.7 1 5.7 0.7 3.6 1.1 6.8 0.4 2.8 1.2 6.5 0.4 290 26 343 255 0 0 0 0 21 0 21.1 20.8 05/08/2005 14:30:00 4.1 1.2 6.8 1.5 3.9 1.3 6.8 1.1 3.3 1.3 6.5 0.4 306 20 296 255 0 0 0 0 21.3 0 21.7 21.1 05/08/2005 14:40:00 4.2 1.1 7.2 1.9 4.1 1.1 7.2 1.5 3.7 1.1 6.5 0.4 293 24 296 255 0 0 0 0 21.4 0.2 22 20.8 05/08/2005 14:50:00 4.2 1 6.5 1.1 4.1 1.1 6.5 1.5 3.4 1.1 6.8 0.4 290 21 281 255 0 0 0 0 21 0.2 21.4 20.5 05/08/2005 15:00:00 4.6 1.3 6.8 1.1 4.4 1.3 7.2 1.1 3.8 1.3 6.8 0.7 294 24 294 255 0 0 0 0 21.3 0.1 21.7 21.1 05/08/2005 15:10:00 4.3 1.5 7.6 0.4 4.2 1.6 7.6 0.4 3.6 1.6 7.2 0.4 286 22 293 255 0 0 0 0 20.9 0.2 21.4 20.5 05/08/2005 15:20:00 4.1 1.4 7.2 1.1 4 1.5 7.2 0.7 3.3 1.6 7.2 0.4 283 23 291 255 0 0 0 0 21.5 0 21.7 21.1 05/08/2005 15:30:00 4.7 1 7.6 1.9 4.6 1 7.6 2.3 3.9 1.1 7.2 1.5 298 19 295 255 0 0 0 0 21.1 0 21.4 20.8 05/08/2005 15:40:00 4.1 1 6.8 1.5 3.9 1 6.5 1.1 3.2 1.2 6.1 0.4 306 21 314 255 0 0 0 0 21.2 0.2 21.7 20.8 05/08/2005 15:50:00 4.2 1.1 6.5 1.5 4.1 1.2 6.1 0.7 3.4 1.3 6.1 0.4 302 18 286 255 0 0 0 0 21.3 0 21.7 21.1 05/08/2005 16:00:00 3.8 1.3 6.5 0.4 3.6 1.5 6.8 0.4 3.1 1.3 6.1 0.4 307 21 303 255 0 0 0 0 21.3 0 21.7 21.1 05/08/2005 16:10:00 4.2 1 6.5 1.1 4 1.1 6.5 1.1 3.2 1.3 6.8 0.4 297 22 281 255 0 0 0 0 21 0.1 21.7 20.8 05/08/2005 16:20:00 3.2 1.4 6.8 0.4 3 1.5 6.8 0.4 2.6 1.5 6.8 0.4 288 28 277 255 0 0 0 0 21.1 0.1 21.4 20.8 05/08/2005 16:30:00 4.3 1.1 7.6 1.5 4.1 1.2 7.2 0.7 3.4 1.3 6.5 0.4 301 18 299 255 0 0 0 0 20.5 0 21.1 20.3 05/08/2005 16:40:00 3.7 1.2 6.5 0.7 3.6 1.2 6.5 0.4 3.1 1.4 6.5 0.4 306 17 297 255 0 0 0 0 20.3 0 20.8 20 05/08/2005 16:50:00 3.7 1 5.3 0.4 3.5 1 5.3 0.4 3.2 1.2 6.1 0.4 292 21 302 255 0 0 0 0 20 0 20.3 20 05/08/2005 17:00:00 3.5 0.7 5.3 1.5 3.4 0.8 5.3 1.5 2.6 0.9 4.9 0.4 293 21 328 255 0 0 0 0 20.1 0 20.5 20 05/08/2005 17:10:00 4 0.8 6.5 1.5 3.9 0.9 5.7 1.1 3.3 1 5.7 1.1 305 15 308 255 0 0 0 0 20 0 20.3 20 05/08/2005 17:20:00 3.5 1.2 6.1 0.4 3.2 1.3 6.1 0.4 2.6 1.5 6.1 0.4 311 17 309 255 0 0 0 0 19.9 0 20 19.7 05/08/2005 17:30:00 3.9 1 5.7 0.7 3.7 1 5.7 0.4 3.1 1 5.3 0.4 306 19 310 255 0 0 0 0 19.9 0.1 20.3 19.7 05/08/2005 17:40:00 3.6 1.1 6.1 0.7 3.5 1.2 6.1 0.4 3 1.2 5.3 0.4 294 21 265 255 0 0 0 0 19.6 0.2 20.3 19.4 05/08/2005 17:50:00 2.8 0.8 4.9 1.1 2.6 0.9 4.6 0.4 1.9 0.9 4.2 0.4 304 22 296 255 0 0 0 0 19.5 0 20 19.4 05/08/2005 18:00:00 3.4 0.9 5.3 1.1 3.2 1 5.3 0.7 2.4 1.1 5.3 0.4 290 23 269 255 0 0 0 0 19.5 0 20 19.4 05/08/2005 18:10:00 2.7 1 4.9 0.7 2.5 1.1 4.9 0.4 2.1 1 4.6 0.4 287 21 283 255 0 0 0 0 19.3 0 19.7 19.1 05/08/2005 18:20:00 3.8 1 5.7 0.7 3.7 1 5.7 0.4 3 1 4.9 0.7 282 17 284 255 0 0 0 0 19.1 0 19.7 18.8 05/08/2005 18:30:00 3.3 1 5.7 0.4 3.1 1.1 5.7 0.4 2.6 1.1 5.3 0.4 296 21 291 255 0 0 0 0 18.9 0 19.1 18.8 05/08/2005 18:40:00 3.6 1 5.7 1.5 3.4 1 5.7 1.1 2.9 1 5.3 0.4 296 20 274 255 0 0 0 0 18.7 0 18.8 18.5 05/08/2005 18:50:00 3 0.8 4.6 0.7 2.8 0.8 4.6 0.7 2.3 1 4.2 0.4 294 18 294 255 0 0 0 0 18.5 0 18.8 18.2 05/08/2005 19:00:00 3.6 1 6.1 1.1 3.5 1 6.5 1.5 2.7 1 5.3 0.4 287 17 296 255 0 0 0 0 18.5 0 18.5 18.2 05/08/2005 19:10:00 3.5 0.8 5.7 1.1 3.3 0.8 5.3 0.4 2.5 0.9 4.9 0.4 289 17 287 255 0 0 0 0 18.3 0 18.5 18 05/08/2005 19:20:00 3.5 1 5.7 1.5 3.4 1.1 6.1 0.7 2.6 1.3 6.1 0.4 286 18 301 255 0 0 0 0 17.9 0 18.2 17.7 05/08/2005 19:30:00 3.2 0.7 5.3 1.5 3 0.8 4.6 1.1 2.4 0.8 4.2 0.7 288 15 281 255 0 0 0 0 17.5 0.1 17.7 17.1 05/08/2005 19:40:00 2.7 0.8 4.9 1.1 2.4 0.9 4.6 0.4 1.7 1 3.8 0.4 286 15 293 255 0 0 0 0 17.1 0.1 17.4 16.8 05/08/2005 19:50:00 2.8 0.7 4.6 1.1 2.5 0.8 4.6 0.4 1.9 0.8 3.8 0.4 294 16 279 255 0 0 0 0 16.6 0 16.8 16.3 05/08/2005 20:00:00 2.8 0.8 4.9 0.7 2.6 0.8 4.9 0.7 1.9 1 4.6 0.4 287 15 255 255 0 0 0 0 16 0 16.6 15.7 05/08/2005 20:10:00 2.6 0.7 4.6 0.7 2.4 0.7 4.6 0.4 1.7 0.7 3.8 0.4 283 15 269 255 0 0 0 0 15.7 0.2 16 15.2 05/08/2005 20:20:00 2.2 0.7 4.9 0.7 1.9 0.8 4.6 0.4 1.2 0.7 3 0.4 279 22 264 255 0 0 0 0 14.9 0.2 15.7 14.6 05/08/2005 20:30:00 3.1 0.7 5.3 1.5 2.9 0.8 4.9 1.1 1.9 0.8 4.6 0.4 285 15 299 255 0 0 0 0 14.8 0 15.2 14.6 05/08/2005 20:40:00 2.3 0.6 4.2 1.1 2 0.7 4.6 0.7 1.3 0.7 3 0.4 288 17 263 255 0 0 0 0 14.4 0.1 14.9 14.1 05/08/2005 20:50:00 2.3 0.8 4.2 0.4 2 1 4.2 0.4 1.2 0.8 4.2 0.4 296 20 307 255 0 0 0 0 14.2 0.2 14.6 13.8 05/08/2005 21:00:00 1 0.5 2.6 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.5 0.4 341 61 278 255 0 0 0 0 13.7 0.3 14.6 13 05/08/2005 21:10:00 2 0.9 3.4 0.4 1.7 0.9 3.4 0.4 1.1 0.8 3 0.4 66 13 51 255 0 0 0 0 12.6 0.3 13.5 11.9 05/08/2005 21:20:00 1.7 0.7 3.4 0.4 1.4 0.8 3 0.4 0.8 0.6 2.3 0.4 23 21 25 255 0 0 0 0 11.7 0.2 12.2 11.1 05/08/2005 21:30:00 2 0.4 3 1.1 1.5 0.5 2.6 0.4 0.6 0.4 2.3 0.4 331 13 331 255 0 0 0 0 10.9 0.2 11.7 10.6 05/08/2005 21:40:00 0.9 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.4 0.2 1.1 0.4 34 43 317 255 0 0 0 0 10.5 0 11.1 10.3 05/08/2005 21:50:00 1.9 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.8 0.5 2.3 0.4 38 15 49 255 0 0 0 0 10.2 0.1 10.6 9.8 05/08/2005 22:00:00 1.4 0.3 1.9 0.7 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 357 21 9 255 0 0 0 0 9.6 0 10.1 9.3 05/08/2005 22:10:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 0.8 0.4 1.9 0.4 299 10 315 255 0 0 0 0 9.4 0 9.8 9.3 05/08/2005 22:20:00 0.8 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 287 3 288 255 0 0 0 0 9.2 0.2 9.8 9 05/08/2005 22:30:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 284 2 283 255 0 0 0 0 8.9 0 9.6 8.8 05/08/2005 22:40:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 324 43 18 255 0 0 0 0 8.5 0.1 9 8.3 05/08/2005 22:50:00 0.9 0.5 2.3 0.4 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 33 16 53 255 0 0 0 0 8.1 0 8.5 8 05/08/2005 23:00:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.8 0.3 1.5 0.4 76 5 65 255 0 0 0 0 7.9 0 8.3 7.8 05/08/2005 23:10:00 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.3 1.9 0.4 87 5 79 255 0 0 0 0 7.6 0.1 8 7.3 05/08/2005 23:20:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 77 6 88 255 0 0 0 0 7.4 0.1 7.8 7.3 05/08/2005 23:30:00 1 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 78 102 108 255 0 0 0 0 7.2 0 7.8 7 05/08/2005 23:40:00 1.2 0.3 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 115 17 88 255 0 0 0 0 6.9 0 7.3 6.7 05/08/2005 23:50:00 1.3 0.3 2.3 0.7 0.9 0.3 1.9 0.4 0.5 0.2 1.5 0.4 110 14 69 255 0 0 0 0 6.7 0 7.3 6.7 05/09/2005 00:00:00 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 64 5 68 255 0 0 0 0 6.6 0.1 6.7 6.2 05/09/2005 00:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 88 22 64 255 0 0 0 0 6.2 0 6.7 6.2 05/09/2005 00:20:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1.4 0.3 1.9 0.4 127 11 138 255 0 0 0 0 5.9 0.1 6.2 5.7 05/09/2005 00:30:00 2.2 0.6 3.4 1.1 2 0.7 3 0.4 1.2 0.6 2.3 0.4 140 6 143 255 0 0 0 0 5.6 0.1 6.2 5.2 05/09/2005 00:40:00 2.9 0.5 3.8 1.5 2.8 0.6 3.8 1.5 2 0.5 3.4 0.7 132 8 134 255 0 0 0 0 5 0.1 5.5 4.8 05/09/2005 00:50:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 0.7 1.9 0.5 3 0.4 131 9 118 255 0 0 0 0 4.8 0 5.2 4.8 05/09/2005 01:00:00 2.9 0.6 4.2 1.1 2.9 0.6 4.2 1.1 2 0.5 3.4 0.4 132 10 133 255 0 0 0 0 4.8 0 5.5 4.5 05/09/2005 01:10:00 2.7 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.4 0.5 2.6 0.4 124 9 113 255 0 0 0 0 4.9 0 5 4.8 05/09/2005 01:20:00 2.2 0.7 3.4 0.4 2 0.7 3.4 0.4 1.1 0.7 3 0.4 126 9 129 255 0 0 0 0 4.8 0 5 4.8 05/09/2005 01:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 126 0 131 255 0 0 0 0 4.9 0 5 4.8 05/09/2005 01:40:00 1 0.7 3 0.4 0.7 0.7 3 0.4 0.4 0.3 1.9 0.4 114 12 113 255 0 0 0 0 4.6 0 4.8 4.5 05/09/2005 01:50:00 2.6 0.5 3.8 0.7 2.3 0.6 3.8 0.4 1.2 0.6 2.3 0.4 111 9 106 255 0 0 0 0 4.8 0 5 4.8 05/09/2005 02:00:00 2.6 0.4 3.8 1.5 2.4 0.5 3.8 1.1 1.1 0.6 2.3 0.4 112 9 126 255 0 0 0 0 4.6 0 4.8 4.5 05/09/2005 02:10:00 3.3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2 0.6 3.4 0.7 112 8 121 255 0 0 0 0 4.6 0 4.8 4.3 05/09/2005 02:20:00 3.4 0.4 4.6 2.3 3.2 0.5 4.2 2.3 1.9 0.6 3.4 0.4 108 9 104 255 0 0 0 0 4.7 0 5 4.5 05/09/2005 02:30:00 2.8 0.6 4.6 1.5 2.6 0.6 4.2 1.1 1.6 0.5 3.4 0.4 119 12 100 255 0 0 0 0 4.5 0 4.8 4.3 05/09/2005 02:40:00 3 0.6 4.6 1.1 2.8 0.6 4.6 1.1 1.5 0.6 3 0.4 114 12 106 255 0 0 0 0 4.3 0 4.5 4.3 05/09/2005 02:50:00 3 0.5 4.9 1.9 2.9 0.5 4.6 1.9 1.6 0.6 3 0.4 115 11 126 255 0 0 0 0 4.4 0 4.5 4.3 05/09/2005 03:00:00 2.7 0.6 4.2 0.7 2.4 0.6 4.2 0.7 1.5 0.5 2.6 0.4 121 11 115 255 0 0 0 0 4.4 0 4.8 4.3 05/09/2005 03:10:00 2.6 0.6 4.2 1.1 2.4 0.7 4.2 0.7 1.4 0.6 3.4 0.4 118 12 117 255 0 0 0 0 4.4 0 4.5 4.3 05/09/2005 03:20:00 3 0.6 4.6 1.5 2.8 0.6 4.2 1.1 1.7 0.6 3.4 0.4 118 11 115 255 0 0 0 0 4.4 0 4.5 4.3 05/09/2005 03:30:00 3.4 0.6 4.9 1.5 3.2 0.7 4.6 1.1 2.1 0.6 3.8 0.7 115 11 103 255 0 0 0 0 4.4 0.1 4.8 4.3 05/09/2005 03:40:00 3.1 0.6 4.6 1.5 3 0.6 4.2 1.5 2 0.6 3.4 0.4 119 11 133 255 0 0 0 0 4.9 0 5 4.8 05/09/2005 03:50:00 3.1 0.6 4.6 1.5 2.9 0.6 4.2 1.5 1.8 0.6 3.4 0.4 117 11 105 255 0 0 0 0 4.7 0.1 5 4.5 05/09/2005 04:00:00 2.7 0.5 4.2 1.5 2.5 0.6 3.8 1.1 1.6 0.5 3 0.4 118 10 116 255 0 0 0 0 4.4 0 4.5 4.3 05/09/2005 04:10:00 2.1 0.5 3.8 1.1 1.9 0.6 3.4 0.7 1.4 0.5 3 0.4 128 13 99 255 0 0 0 0 4 0 4.3 4 05/09/2005 04:20:00 2.3 0.5 3.4 0.7 2.1 0.6 3.4 0.4 1.5 0.5 2.6 0.4 137 12 113 255 0 0 0 0 4 0 4.3 3.8 05/09/2005 04:30:00 1.9 0.6 3.4 0.7 1.6 0.7 3.4 0.4 0.9 0.7 2.6 0.4 137 10 140 255 0 0 0 0 3.9 0 4 3.5 05/09/2005 04:40:00 1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 119 11 111 255 0 0 0 0 3.6 0 3.8 3.5 05/09/2005 04:50:00 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.7 0.4 109 10 125 255 0 0 0 0 3.5 0 3.8 3.5 05/09/2005 05:00:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 110 5 119 255 0 0 0 0 3.4 0 3.5 3.3 05/09/2005 05:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 108 0 108 255 0 0 0 0 3.4 0 3.5 3.3 05/09/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 108 0 255 255 0 0 0 0 3.5 0 3.5 3.3 05/09/2005 05:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 108 0 108 255 0 0 0 0 3.8 0 4 3.5 05/09/2005 05:40:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 133 18 129 255 0 0 0 0 4.1 0 4.5 3.8 05/09/2005 05:50:00 1.6 0.4 2.6 0.7 1.4 0.5 2.3 0.4 0.9 0.5 1.9 0.4 129 10 133 255 0 0 0 0 4.8 0.3 5.5 4.3 05/09/2005 06:00:00 1.5 0.4 2.6 0.4 1.1 0.5 2.6 0.4 0.5 0.3 1.9 0.4 120 9 121 255 0 0 0 0 5.6 0.1 5.7 5.2 05/09/2005 06:10:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 119 13 112 255 0 0 0 0 6.2 0.2 6.7 5.7 05/09/2005 06:20:00 0.5 0.3 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 126 6 112 255 0 0 0 0 7.1 0.3 7.8 6.7 05/09/2005 06:30:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 127 0 127 255 0 0 0 0 8.2 0.3 9 7.8 05/09/2005 06:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 126 0 127 255 0 0 0 0 9.4 0 9.6 9 05/09/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 8 124 255 0 0 0 0 10.3 0.3 10.9 9.6 05/09/2005 07:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 73 21 92 255 0 0 0 0 11.2 0.1 11.4 10.9 05/09/2005 07:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 39 35 76 255 0 0 0 0 11.3 0 11.7 11.1 05/09/2005 07:20:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 10 19 34 255 0 0 0 0 11.8 0.1 12.2 11.4 05/09/2005 07:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 49 41 97 255 0 0 0 0 12.3 0 12.7 11.9 05/09/2005 07:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.1 0.4 54 18 35 255 0 0 0 0 12.6 0.2 13.3 12.2 05/09/2005 07:50:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 16 22 8 255 0 0 0 0 13.3 0.1 13.8 12.7 05/09/2005 08:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 9 15 6 255 0 0 0 0 13.3 0 13.5 13 05/09/2005 08:10:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 17 20 18 255 0 0 0 0 13.8 0 14.4 13.5 05/09/2005 08:20:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 358 17 346 255 0 0 0 0 14.2 0.1 14.6 13.8 05/09/2005 08:30:00 1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.3 1.9 0.4 354 14 4 255 0 0 0 0 14.3 0.2 14.9 13.8 05/09/2005 08:40:00 0.7 0.4 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.9 0.4 33 20 13 255 0 0 0 0 14.8 0 15.2 14.6 05/09/2005 08:50:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 15 22 350 255 0 0 0 0 15 0 15.2 14.9 05/09/2005 09:00:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 28 21 21 255 0 0 0 0 15.3 0 15.7 15.2 05/09/2005 09:10:00 0.8 0.4 2.3 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 9 22 21 255 0 0 0 0 15.7 0 16 15.7 05/09/2005 09:20:00 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 46 27 54 255 0 0 0 0 15.8 0 16.3 15.7 05/09/2005 09:30:00 1.6 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 38 22 37 255 0 0 0 0 16.4 0.2 17.1 16 05/09/2005 09:40:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.3 0.7 3 0.4 11 14 16 255 0 0 0 0 16.8 0 17.4 16.6 05/09/2005 09:50:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 1 0.8 3 0.4 9 22 14 255 0 0 0 0 17.2 0.4 18.2 16.8 05/09/2005 10:00:00 2.2 0.5 3.4 0.7 2 0.5 3 0.4 1.7 0.6 3 0.4 26 20 50 255 0 0 0 0 17.8 0.2 18.2 17.4 05/09/2005 10:10:00 2.1 0.5 3.4 0.7 1.9 0.5 3 0.4 1.6 0.6 3 0.4 17 13 12 255 0 0 0 0 17.8 0 18.5 17.4 05/09/2005 10:20:00 2.3 0.7 4.2 0.4 2 0.9 4.2 0.4 1.6 0.8 3.8 0.4 349 49 293 255 0 0 0 0 18.2 0.1 18.5 18 05/09/2005 10:30:00 2.5 0.6 3.8 0.7 2.3 0.7 3.8 0.4 2 0.7 3.4 0.4 303 24 292 255 0 0 0 0 18 0 18.5 17.7 05/09/2005 10:40:00 1.9 1 4.2 0.4 1.7 1 4.2 0.4 1.7 1 3.4 0.4 282 41 294 255 0 0 0 0 17.9 0.1 18.5 17.4 05/09/2005 10:50:00 1.8 0.6 3.8 0.4 1.4 0.6 3.4 0.4 1.3 0.7 2.6 0.4 301 43 257 255 0 0 0 0 18.7 0.2 19.4 18.2 05/09/2005 11:00:00 2.1 0.9 3.8 0.4 1.9 1 4.2 0.4 1.7 1 3.8 0.4 318 36 270 255 0 0 0 0 18.9 0.3 19.4 18.2 05/09/2005 11:10:00 2.3 0.9 4.6 0.4 2.1 0.9 4.6 0.4 1.6 1 4.2 0.4 306 38 307 255 0 0 0 0 18.8 0.1 19.4 18.5 05/09/2005 11:20:00 2.2 1 5.7 0.4 2.1 1.1 5.7 0.4 1.7 1 4.9 0.4 259 22 260 255 0 0 0 0 19.2 0 19.4 19.1 05/09/2005 11:30:00 2.3 0.7 4.2 0.4 2.1 0.8 4.2 0.4 1.7 1 4.2 0.4 260 36 266 255 0 0 0 0 19.4 0 19.7 19.1 05/09/2005 11:40:00 2.9 1 5.3 0.7 2.6 1.2 5.3 0.4 2.1 1.3 5.3 0.4 305 30 306 255 0 0 0 0 19.1 0.1 19.4 18.5 05/09/2005 11:50:00 2.7 0.7 4.2 0.4 2.5 0.7 4.2 0.7 2.3 0.9 4.6 0.4 285 32 342 255 0 0 0 0 19.2 0.1 19.4 18.8 05/09/2005 12:00:00 1.9 1 4.2 0.4 1.7 1.1 4.2 0.4 1.5 1 4.2 0.4 271 30 265 255 0 0 0 0 20 0.4 20.8 19.4 05/09/2005 12:10:00 2.8 0.7 4.6 1.5 2.6 0.7 4.9 1.1 2.5 0.7 4.6 0.7 317 20 326 255 0 0 0 0 20.2 0.2 20.8 19.7 05/09/2005 12:20:00 2.8 0.7 5.3 1.1 2.4 0.7 4.6 0.7 1.9 0.8 4.2 0.4 341 29 323 255 0 0 0 0 20.4 0.1 21.1 20 05/09/2005 12:30:00 2.1 1 4.6 0.4 1.9 1 4.2 0.4 1.5 0.9 3.8 0.4 290 79 266 255 0 0 0 0 20.7 0.3 21.7 20.3 05/09/2005 12:40:00 2.6 0.7 4.6 0.7 2.5 0.7 4.2 0.4 2.1 0.8 4.6 0.4 298 38 269 255 0 0 0 0 21 0.3 21.7 20.5 05/09/2005 12:50:00 1.9 1 4.2 0.4 1.8 1.1 4.2 0.4 1.3 0.9 4.2 0.4 249 79 219 255 0 0 0 0 21.3 0 21.7 21.1 05/09/2005 13:00:00 2.3 1.4 5.3 0.4 2.2 1.5 5.7 0.4 1.8 1.3 5.3 0.4 246 49 279 255 0 0 0 0 21.2 0 21.4 21.1 05/09/2005 13:10:00 2.6 1.4 5.7 0.4 2.4 1.5 5.7 0.4 2.1 1.5 5.7 0.4 307 39 264 255 0 0 0 0 21.4 0.2 21.7 20.8 05/09/2005 13:20:00 2.1 0.8 4.6 0.4 1.9 0.9 4.6 0.4 1.6 0.8 3.4 0.4 302 26 268 255 0 0 0 0 21.3 0.3 22.3 20.5 05/09/2005 13:30:00 2.3 1.3 5.3 0.4 2.1 1.3 4.9 0.4 1.4 1.2 4.9 0.4 274 43 254 255 0 0 0 0 21.6 0.1 22.3 21.1 05/09/2005 13:40:00 3.2 1 5.7 0.4 2.9 1.1 6.1 0.4 2.5 1.1 5.7 0.4 311 23 298 255 0 0 0 0 21.8 0.3 22.6 21.1 05/09/2005 13:50:00 2.8 1 4.9 0.7 2.6 1 4.9 0.4 2.2 1.1 4.6 0.4 287 28 235 255 0 0 0 0 21.9 0.2 22.3 21.4 05/09/2005 14:00:00 2.5 1.2 5.3 0.4 2.2 1.3 5.3 0.4 1.8 1.2 5.7 0.4 294 41 305 255 0 0 0 0 22 0 22.3 21.7 05/09/2005 14:10:00 2.2 1 4.6 0.4 2 1 4.6 0.4 1.5 1 3.8 0.4 280 29 253 255 0 0 0 0 21.9 0.2 22.6 21.4 05/09/2005 14:20:00 2.5 1 4.6 0.4 2.2 1.1 4.6 0.4 1.8 1.2 4.9 0.4 291 41 300 255 0 0 0 0 22.3 0 22.6 22 05/09/2005 14:30:00 2.1 1 4.9 0.4 1.8 1 4.6 0.4 1.4 0.9 4.6 0.4 317 29 277 255 0 0 0 0 22.4 0.3 23.2 22 05/09/2005 14:40:00 3.1 1.2 5.3 0.4 2.9 1.2 5.3 0.4 2.2 1.2 5.3 0.4 315 30 294 255 0 0 0 0 23 0.2 23.5 22.9 05/09/2005 14:50:00 2.8 0.9 5.3 1.1 2.5 0.9 5.3 0.7 2.3 0.9 4.6 0.4 308 20 281 255 0 0 0 0 22.6 0 22.9 22.3 05/09/2005 15:00:00 2.9 1.4 6.1 0.4 2.7 1.5 6.1 0.4 2.1 1.1 4.9 0.4 289 58 299 255 0 0 0 0 22.4 0 22.6 22.3 05/09/2005 15:10:00 3.9 1.1 6.8 1.5 3.7 1.2 7.2 0.7 3.1 1.2 6.5 0.4 295 26 287 255 0 0 0 0 22.4 0.1 22.6 22.3 05/09/2005 15:20:00 3.7 1 6.5 1.5 3.4 1 6.1 1.1 2.8 1.4 6.1 0.4 307 28 300 255 0 0 0 0 22.4 0 22.6 22.3 05/09/2005 15:30:00 4 1.3 7.2 0.4 3.8 1.3 6.8 0.4 3.1 1.2 6.1 0.4 300 18 314 255 0 0 0 0 22.2 0 22.6 22.3 05/09/2005 15:40:00 2.4 1 4.6 0.4 2.2 1 4.6 0.4 1.7 1 4.2 0.4 288 39 286 255 0 0 0 0 22.7 0.1 23.2 22.3 05/09/2005 15:50:00 3.7 1 5.7 0.4 3.6 1 5.7 0.4 2.9 1 5.3 0.4 306 20 301 255 0 0 0 0 22.4 0 22.6 22.3 05/09/2005 16:00:00 4.1 0.9 7.2 1.9 4 1 7.2 1.5 3.4 1.1 5.3 0.4 299 18 273 255 0 0 0 0 22.1 0.1 22.3 21.7 05/09/2005 16:10:00 3.5 0.8 5.7 1.5 3.3 0.9 5.7 1.5 2.9 0.9 5.3 0.7 315 24 297 255 0 0 0 0 21.9 0 22 21.7 05/09/2005 16:20:00 3.1 0.8 4.9 0.4 2.8 0.8 4.6 0.7 2.2 1 4.6 0.4 300 19 281 255 0 0 0 0 21.6 0 21.7 21.7 05/09/2005 16:30:00 3.2 1.2 6.1 0.7 3 1.2 5.7 0.4 2.4 1.2 4.9 0.4 313 20 295 255 0 0 0 0 21.6 0 22 21.4 05/09/2005 16:40:00 2.8 1 5.3 0.4 2.5 1.1 5.3 0.4 1.9 1.2 4.6 0.4 305 32 301 255 0 0 0 0 21.6 0 22 21.4 05/09/2005 16:50:00 2.7 1 5.7 0.4 2.4 1 5.7 0.4 2 1.1 5.3 0.4 303 29 292 255 0 0 0 0 21.3 0 21.7 21.1 05/09/2005 17:00:00 2.4 0.9 4.6 0.4 2.2 1 4.6 0.4 1.8 1 4.9 0.4 305 30 314 255 0 0 0 0 21.2 0 21.7 21.1 05/09/2005 17:10:00 2.9 0.8 4.9 0.7 2.7 0.9 4.6 0.4 2.1 0.9 4.2 0.4 311 17 304 255 0 0 0 0 21.1 0 21.7 20.8 05/09/2005 17:20:00 2.8 1.1 4.6 0.7 2.6 1.2 4.6 0.4 2.1 1.3 4.6 0.4 308 21 322 255 0 0 0 0 20.7 0.1 21.1 20.5 05/09/2005 17:30:00 2.8 0.6 4.2 0.4 2.5 0.7 4.6 0.4 2.1 0.8 3.8 0.4 310 16 293 255 0 0 0 0 20.5 0 20.5 20.5 05/09/2005 17:40:00 2.4 1 4.6 0.4 2.1 1.1 4.6 0.4 1.9 1 4.2 0.4 292 32 286 255 0 0 0 0 20.5 0 20.5 20.3 05/09/2005 17:50:00 2.9 0.7 4.6 1.5 2.7 0.8 4.6 1.1 2.3 1.1 4.6 0.4 295 13 293 255 0 0 0 0 20.3 0.1 20.8 20 05/09/2005 18:00:00 3.1 0.6 4.9 1.9 3 0.7 4.6 1.1 2.3 0.9 4.2 0.4 298 14 286 255 0 0 0 0 20.2 0 20.5 20 05/09/2005 18:10:00 2.4 0.7 4.2 0.4 2 0.7 4.2 0.4 1.5 0.9 4.2 0.4 334 18 332 255 0 0 0 0 20 0 20.5 19.7 05/09/2005 18:20:00 2.3 0.6 3.8 1.1 1.9 0.6 3.4 0.4 1.5 0.7 3.4 0.4 320 22 342 255 0 0 0 0 19.7 0.1 20.3 19.4 05/09/2005 18:30:00 2.5 0.5 3.4 1.1 2.2 0.6 3.4 0.7 1.9 0.8 3.8 0.4 295 17 266 255 0 0 0 0 19.6 0.1 20.3 19.4 05/09/2005 18:40:00 1.8 0.7 3.4 0.4 1.5 0.8 3.4 0.4 0.9 0.7 3.4 0.4 282 20 268 255 0 0 0 0 19.5 0 20 19.4 05/09/2005 18:50:00 1.9 0.5 3 0.4 1.6 0.7 3 0.4 1 0.6 2.6 0.4 267 13 259 255 0 0 0 0 19.2 0 19.7 19.1 05/09/2005 19:00:00 1.9 0.5 3 0.4 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 295 15 307 255 0 0 0 0 18.9 0 19.4 18.5 05/09/2005 19:10:00 2 0.5 3 0.7 1.7 0.6 2.6 0.4 1.3 0.6 3 0.4 284 15 284 255 0 0 0 0 18.4 0 18.8 18.2 05/09/2005 19:20:00 2.1 0.7 4.2 0.4 1.7 0.8 4.2 0.4 1.2 0.7 2.6 0.4 296 24 348 255 0 0 0 0 18.1 0.1 18.2 18 05/09/2005 19:30:00 3.1 0.6 4.6 1.5 2.8 0.7 4.6 1.1 1.6 0.8 3.4 0.4 351 12 356 255 0 0 0 0 17.4 0.2 18 16.8 05/09/2005 19:40:00 3.1 0.6 4.6 1.5 2.9 0.6 4.6 1.1 1.9 0.8 3.8 0.4 14 11 1 255 0 0 0 0 16.8 0 17.1 16.8 05/09/2005 19:50:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.5 1.6 0.7 3.8 0.4 16 9 9 255 0 0 0 0 16.4 0.1 16.8 16.3 05/09/2005 20:00:00 3.3 0.6 4.6 1.1 3.1 0.7 4.6 0.7 1.9 0.9 4.2 0.4 6 12 20 255 0 0 0 0 16 0 16.3 15.7 05/09/2005 20:10:00 3 0.5 3.8 1.5 2.8 0.5 3.8 1.1 1.5 0.7 3 0.4 7 9 4 255 0 0 0 0 15.5 0.2 16 15.2 05/09/2005 20:20:00 2.6 0.5 3.8 1.1 2.4 0.6 3.4 0.7 1.3 0.7 3 0.4 20 10 2 255 0 0 0 0 14.8 0 15.2 14.6 05/09/2005 20:30:00 2.9 0.6 4.2 1.5 2.8 0.6 4.2 1.5 1.4 0.7 3 0.4 21 8 34 255 0 0 0 0 14.2 0.2 14.9 13.5 05/09/2005 20:40:00 3.3 0.6 4.9 1.9 3.1 0.7 4.6 1.5 2.1 0.8 4.6 0.4 26 8 21 255 0 0 0 0 13.5 0.1 14.1 13 05/09/2005 20:50:00 2.8 0.6 4.6 1.1 2.6 0.7 4.2 0.7 1.8 0.8 3.4 0.4 25 9 26 255 0 0 0 0 12.9 0.1 13.5 12.5 05/09/2005 21:00:00 1.9 0.4 3 0.7 1.7 0.5 3 0.4 0.7 0.4 1.9 0.4 9 12 48 255 0 0 0 0 12.3 0 12.7 12.2 05/09/2005 21:10:00 1.3 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.4 0.2 1.5 0.4 30 8 21 255 0 0 0 0 12.3 0 12.7 12.2 05/09/2005 21:20:00 1.9 0.3 2.6 1.5 1.6 0.3 2.6 0.7 1 0.4 1.9 0.4 48 6 54 255 0 0 0 0 12 0.2 12.7 11.7 05/09/2005 21:30:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 0.7 0.3 1.5 0.4 47 4 42 255 0 0 0 0 11.5 0.1 11.7 11.1 05/09/2005 21:40:00 1.7 0.3 2.6 0.7 1.4 0.4 2.6 0.4 0.8 0.4 1.9 0.4 54 6 48 255 0 0 0 0 10.9 0.2 11.1 10.6 05/09/2005 21:50:00 2.2 0.4 3 1.1 1.9 0.4 3 0.7 1.1 0.5 2.3 0.4 44 5 49 255 0 0 0 0 10.6 0 11.1 10.3 05/09/2005 22:00:00 2 0.4 3 0.7 1.7 0.5 2.6 0.4 0.6 0.4 1.5 0.4 53 5 55 255 0 0 0 0 10.2 0 10.6 9.8 05/09/2005 22:10:00 1.4 0.4 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 64 8 70 255 0 0 0 0 10 0 10.3 9.8 05/09/2005 22:20:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.4 0.7 0.3 1.5 0.4 67 9 58 255 0 0 0 0 9.7 0.1 10.1 9.6 05/09/2005 22:30:00 1.9 0.3 2.6 1.1 1.6 0.4 2.3 0.4 1.1 0.3 1.9 0.4 76 7 77 255 0 0 0 0 9.4 0 9.6 9 05/09/2005 22:40:00 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 0.7 0.4 1.5 0.4 74 9 78 255 0 0 0 0 8.9 0 9.6 8.8 05/09/2005 22:50:00 1.6 0.4 2.6 0.7 1.3 0.5 2.6 0.4 0.6 0.4 1.5 0.4 67 10 74 255 0 0 0 0 8.6 0.1 9.3 8.5 05/09/2005 23:00:00 1.6 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.5 0.3 1.5 0.4 96 10 105 255 0 0 0 0 8.3 0 8.8 8.3 05/09/2005 23:10:00 1.7 0.4 3 0.7 1.3 0.5 2.6 0.4 0.8 0.4 1.5 0.4 110 8 106 255 0 0 0 0 8 0 8.5 7.8 05/09/2005 23:20:00 2.3 0.3 3 1.5 2 0.3 3 1.1 1.3 0.4 2.3 0.4 93 10 104 255 0 0 0 0 7.6 0.1 8 7.5 05/09/2005 23:30:00 2.5 0.3 3.4 1.5 2.3 0.4 3 1.1 1.3 0.5 2.3 0.4 97 8 74 255 0 0 0 0 7.4 0 7.8 7.3 05/09/2005 23:40:00 2.6 0.4 3.4 1.9 2.4 0.4 3.8 1.5 1.4 0.5 2.6 0.4 85 9 91 255 0 0 0 0 7.3 0 7.8 7.3 05/09/2005 23:50:00 2.5 0.3 3.4 1.9 2.4 0.3 3 1.5 1.3 0.4 2.3 0.4 92 7 74 255 0 0 0 0 7 0 7.3 6.7 05/10/2005 00:00:00 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.5 1.7 0.4 2.6 0.4 90 8 91 255 0 0 0 0 6.7 0 7.3 6.7 05/10/2005 00:10:00 2.8 0.3 3.8 1.9 2.7 0.4 3.8 1.9 1.6 0.4 2.6 0.7 84 9 74 255 0 0 0 0 6.6 0 7 6.5 05/10/2005 00:20:00 2.8 0.5 4.2 1.9 2.6 0.5 3.8 1.1 1.8 0.4 3 0.4 107 12 108 255 0 0 0 0 6.4 0.1 6.7 6.2 05/10/2005 00:30:00 2.8 0.5 4.2 1.1 2.6 0.5 3.8 1.1 1.7 0.5 3 0.4 114 13 118 255 0 0 0 0 6.1 0 6.2 6 05/10/2005 00:40:00 3.3 0.6 4.6 1.5 3.2 0.6 4.9 1.5 1.9 0.7 3.8 0.4 107 9 100 255 0 0 0 0 6.1 0 6.5 6 05/10/2005 00:50:00 3.2 0.5 4.6 1.5 3.1 0.5 4.2 1.5 1.9 0.6 3.4 0.4 103 10 101 255 0 0 0 0 6.2 0.1 6.7 6 05/10/2005 01:00:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 1.9 2.1 0.5 3 0.7 94 7 95 255 0 0 0 0 6.2 0 6.7 6 05/10/2005 01:10:00 3.1 0.3 4.2 2.3 2.9 0.3 3.8 2.3 2 0.4 2.6 1.1 99 8 86 255 0 0 0 0 5.9 0.1 6.2 5.7 05/10/2005 01:20:00 2.6 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.1 0.6 2.6 0.4 111 9 109 255 0 0 0 0 5.7 0 6.2 5.7 05/10/2005 01:30:00 2.1 0.5 3.4 0.7 1.8 0.6 3.4 0.4 0.7 0.5 2.3 0.4 116 8 113 255 0 0 0 0 5.9 0 6 5.7 05/10/2005 01:40:00 2.2 0.5 3 0.7 2 0.5 3 0.7 0.7 0.4 1.9 0.4 117 9 118 255 0 0 0 0 5.6 0 5.7 5.5 05/10/2005 01:50:00 2.2 0.5 3.4 1.1 2 0.6 3.4 0.7 1 0.5 3 0.4 121 8 113 255 0 0 0 0 5.3 0 5.7 5.2 05/10/2005 02:00:00 2.2 0.6 3.8 1.1 2 0.7 3.4 0.4 1.1 0.6 2.6 0.4 120 11 121 255 0 0 0 0 5.1 0 5.7 5 05/10/2005 02:10:00 2.2 0.5 3.4 0.7 1.9 0.6 3 0.4 1 0.6 2.6 0.4 108 11 103 255 0 0 0 0 4.9 0 5 4.8 05/10/2005 02:20:00 3 0.5 4.2 1.9 2.9 0.5 3.8 1.5 1.7 0.5 3 0.4 116 9 117 255 0 0 0 0 5 0 5 4.8 05/10/2005 02:30:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.9 2 0.6 4.2 0.4 112 10 108 255 0 0 0 0 5 0.1 5.5 4.8 05/10/2005 02:40:00 2.9 0.7 4.9 1.5 2.7 0.7 4.9 1.1 1.5 0.6 3.4 0.4 119 12 125 255 0 0 0 0 5.4 0.1 5.7 5 05/10/2005 02:50:00 2.1 0.4 3.8 1.1 1.8 0.5 3.4 0.7 1.5 0.5 2.6 0.4 127 12 102 255 0 0 0 0 5.3 0 5.5 5 05/10/2005 03:00:00 2.4 0.4 3.8 1.1 2.2 0.5 3.4 0.7 1.3 0.5 3 0.4 121 9 122 255 0 0 0 0 5.2 0.1 5.5 5 05/10/2005 03:10:00 2.3 0.4 3.4 1.5 2.1 0.5 3 1.1 1.6 0.5 3 0.4 124 9 113 255 0 0 0 0 4.9 0 5 4.8 05/10/2005 03:20:00 2.5 0.4 3.8 1.5 2.4 0.4 3.8 1.1 2 0.5 3.4 0.4 126 10 116 255 0 0 0 0 5.3 0.4 6 4.8 05/10/2005 03:30:00 2.3 0.4 3.8 1.1 2.1 0.5 3.4 0.7 1.6 0.4 2.6 0.4 128 9 104 255 0 0 0 0 5.4 0.2 6 5 05/10/2005 03:40:00 1.6 0.6 3 0.4 1.3 0.7 3 0.4 0.8 0.6 2.3 0.4 125 11 138 255 0 0 0 0 4.8 0.2 5 4.5 05/10/2005 03:50:00 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0 0.7 0.4 115 1 116 255 0 0 0 0 4.4 0 4.5 4 05/10/2005 04:00:00 1.7 0.4 2.6 0.4 1.4 0.5 2.6 0.4 0.5 0.3 1.9 0.4 113 6 109 255 0 0 0 0 4 0 4.3 3.8 05/10/2005 04:10:00 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 0.5 0.3 1.9 0.4 112 7 116 255 0 0 0 0 3.8 0.1 4 3.5 05/10/2005 04:20:00 1.8 0.5 3.4 0.7 1.5 0.6 3 0.4 0.7 0.4 1.9 0.4 123 8 118 255 0 0 0 0 3.5 0 3.5 3.5 05/10/2005 04:30:00 2.2 0.4 3.4 1.1 2.1 0.5 3 0.7 1.3 0.5 2.6 0.4 154 15 158 255 0 0 0 0 3.3 0 3.5 3.3 05/10/2005 04:40:00 1.9 0.4 2.6 0.4 2.1 0.4 2.6 0.4 1.1 0.5 2.6 0.4 183 7 198 255 0 0 0 0 2.9 0 3.3 2.8 05/10/2005 04:50:00 1.6 0.3 2.3 0.7 1.5 0.3 1.9 0.7 0.7 0.3 1.5 0.4 168 6 168 255 0 0 0 0 2.9 0 3.3 2.8 05/10/2005 05:00:00 1.3 0.3 1.9 0.7 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 159 2 160 255 0 0 0 0 3 0 3.3 2.8 05/10/2005 05:10:00 1.4 0.4 2.3 0.4 1.1 0.5 1.9 0.4 0.6 0.4 1.9 0.4 151 8 146 255 0 0 0 0 3.2 0 3.5 2.8 05/10/2005 05:20:00 1.6 0.4 2.6 0.7 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 128 12 122 255 0 0 0 0 3.4 0 3.5 3.3 05/10/2005 05:30:00 2.1 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.5 0.5 2.6 0.4 141 9 136 255 0 0 0 0 3.6 0.1 4 3.5 05/10/2005 05:40:00 1.2 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 138 10 149 255 0 0 0 0 4.4 0.3 5 4 05/10/2005 05:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 155 1 148 255 0 0 0 0 5.4 0.3 6 4.8 05/10/2005 06:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 0 155 255 0 0 0 0 6.4 0.2 7 6 05/10/2005 06:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 0 155 255 0 0 0 0 7.1 0.1 7.5 7 05/10/2005 06:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 1 158 255 0 0 0 0 7.5 0 7.8 7.3 05/10/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 255 255 0 0 0 0 8.5 0.4 9 7.8 05/10/2005 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 95 41 74 255 0 0 0 0 9.4 0.2 9.8 9 05/10/2005 06:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 0 302 255 0 0 0 0 10.1 0.2 10.6 9.8 05/10/2005 07:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 336 41 302 255 0 0 0 0 11.3 0.2 11.9 10.6 05/10/2005 07:10:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 104 69 219 255 0 0 0 0 11.7 0.1 12.2 11.4 05/10/2005 07:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 224 6 221 255 0 0 0 0 11.7 0 12.2 11.4 05/10/2005 07:30:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 244 12 234 255 0 0 0 0 11.3 0.1 11.9 11.1 05/10/2005 07:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 153 36 223 255 0 0 0 0 11.7 0 12.2 11.4 05/10/2005 07:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 143 79 273 255 0 0 0 0 12.3 0.2 12.7 11.7 05/10/2005 08:00:00 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 253 33 282 255 0 0 0 0 12.9 0.1 13.3 12.7 05/10/2005 08:10:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 216 20 235 255 0 0 0 0 13.5 0.2 14.1 12.7 05/10/2005 08:20:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.5 1.9 0.4 246 27 209 255 0 0 0 0 13.9 0.2 14.4 13.3 05/10/2005 08:30:00 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 175 23 158 255 0 0 0 0 14.2 0.1 14.6 14.1 05/10/2005 08:40:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 85 82 313 255 0 0 0 0 14.4 0.3 14.9 13.8 05/10/2005 08:50:00 1.5 0.7 3 0.4 1.2 0.7 3 0.4 0.8 0.5 2.3 0.4 285 30 308 255 0 0 0 0 15 0 15.2 14.9 05/10/2005 09:00:00 1.4 0.7 3.4 0.4 1.1 0.7 3 0.4 0.9 0.7 2.6 0.4 298 47 308 255 0 0 0 0 15.3 0.2 16 14.9 05/10/2005 09:10:00 1.7 0.6 3 0.4 1.4 0.6 3 0.4 1 0.7 3 0.4 323 27 298 255 0 0 0 0 15.5 0 16 15.5 05/10/2005 09:20:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.8 3 0.4 294 28 307 255 0 0 0 0 15.7 0.1 16.6 15.7 05/10/2005 09:30:00 2 0.8 4.2 0.4 1.8 0.9 3.8 0.4 1.6 0.9 3.8 0.4 282 35 291 255 0 0 0 0 15.7 0.2 16.6 15.2 05/10/2005 09:40:00 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.7 3 0.4 292 39 305 255 0 0 0 0 16 0.2 16.8 15.7 05/10/2005 09:50:00 2.6 0.9 4.6 0.4 2.3 1 4.6 0.4 1.8 1 4.2 0.4 300 39 307 255 0 0 0 0 16.2 0 16.8 16 05/10/2005 10:00:00 2.9 1 4.9 0.4 2.7 1 4.9 0.4 2.2 1.1 4.2 0.4 308 15 346 255 0 0 0 0 15.8 0.2 16.6 15.7 05/10/2005 10:10:00 2.4 1 4.6 0.4 2.1 1.1 4.9 0.4 1.7 1.1 4.2 0.4 304 33 261 255 0 0 0 0 16.5 0.1 17.1 16.3 05/10/2005 10:20:00 2.9 0.9 4.9 0.7 2.7 1 4.9 0.4 2.5 0.9 4.9 0.7 297 24 277 255 0 0 0 0 16.6 0.2 17.4 16.3 05/10/2005 10:30:00 3.3 0.9 5.3 1.1 3.1 1 5.3 0.4 2.7 1.1 5.7 0.4 303 28 306 255 0 0 0 0 17 0 17.4 16.8 05/10/2005 10:40:00 3.1 1 5.3 0.7 2.9 1 5.3 0.7 2.4 1.1 4.9 0.4 295 22 273 255 0 0 0 0 16.9 0 17.1 16.8 05/10/2005 10:50:00 2.5 0.9 4.6 0.4 2.4 1 4.6 0.4 2 1 5.3 0.4 256 32 255 255 0 0 0 0 17.3 0.2 18 16.8 05/10/2005 11:00:00 2.6 1 4.6 0.4 2.4 1.1 4.9 0.4 2 1.2 4.6 0.4 280 32 266 255 0 0 0 0 17.4 0.2 18.2 16.8 05/10/2005 11:10:00 2.8 1 5.7 0.7 2.6 1.1 5.3 0.4 2.1 1.2 4.9 0.4 282 35 254 255 0 0 0 0 17.7 0 18.2 17.4 05/10/2005 11:20:00 3.5 1 5.7 0.4 3.2 1.1 5.7 0.4 2.6 1.3 5.7 0.4 296 29 275 255 0 0 0 0 17.9 0.1 18.5 17.4 05/10/2005 11:30:00 3.8 1 6.5 1.1 3.6 1.1 5.7 0.4 3 1.1 5.7 0.4 300 20 263 255 0 0 0 0 17.5 0.2 18.2 17.1 05/10/2005 11:40:00 3.1 1.3 6.1 0.4 2.8 1.5 6.1 0.4 2.5 1.4 5.7 0.4 295 28 288 255 0 0 0 0 17.9 0.1 18.5 17.7 05/10/2005 11:50:00 3 0.9 4.9 0.7 2.8 1 4.9 0.4 2.3 1.1 4.9 0.4 297 22 302 255 0 0 0 0 18.5 0.2 19.1 18 05/10/2005 12:00:00 2.8 0.9 4.9 0.7 2.6 1 4.9 0.4 2.3 1.1 4.9 0.4 266 26 262 255 0 0 0 0 18.6 0.1 18.8 18.2 05/10/2005 12:10:00 2.7 1 5.7 0.4 2.6 1.1 5.7 0.4 2.1 1 4.9 0.4 280 32 212 255 0 0 0 0 18.9 0.3 19.4 18.2 05/10/2005 12:20:00 3.2 0.9 5.3 0.7 3.1 1 5.7 0.4 2.3 1.1 4.6 0.4 280 22 263 255 0 0 0 0 18.8 0 19.4 18.5 05/10/2005 12:30:00 2.7 1.3 6.1 0.4 2.5 1.3 5.7 0.4 2.1 1 5.3 0.4 292 41 326 255 0 0 0 0 19 0 19.4 18.8 05/10/2005 12:40:00 3.3 1.1 5.7 0.4 3.2 1.1 5.7 0.4 2.6 1.2 5.7 0.4 293 22 323 255 0 0 0 0 19.4 0 19.4 19.1 05/10/2005 12:50:00 3.8 1.2 6.8 1.1 3.5 1.2 6.8 0.7 2.7 1.2 6.1 0.4 306 24 318 255 0 0 0 0 19.5 0 20 19.4 05/10/2005 13:00:00 3.1 1 5.7 0.4 2.9 1.1 6.1 0.4 2.3 1.3 6.1 0.4 295 29 269 255 0 0 0 0 19.9 0.4 20.8 19.4 05/10/2005 13:10:00 3.3 1 5.7 1.1 3.1 1 5.3 0.4 2.4 1.1 4.9 0.4 306 23 317 255 0 0 0 0 20.3 0.1 20.5 20 05/10/2005 13:20:00 2.4 1.1 5.3 0.4 2.3 1.1 4.9 0.4 2 1.1 4.9 0.4 287 30 268 255 0 0 0 0 20.2 0.3 21.1 19.7 05/10/2005 13:30:00 3.3 1.1 5.7 0.4 3.1 1.1 5.7 0.4 2.3 1.2 4.9 0.4 293 35 310 255 0 0 0 0 20.7 0.2 21.4 20.3 05/10/2005 13:40:00 3.2 1.1 6.5 0.4 2.9 1.1 6.1 0.4 2.8 1.3 5.7 0.4 308 28 324 255 0 0 0 0 20.3 0.2 20.8 20 05/10/2005 13:50:00 3.5 1.2 6.5 0.4 3.3 1.3 6.8 0.4 2.6 1.2 6.1 0.4 315 29 299 255 0 0 0 0 21 0.3 21.7 20.3 05/10/2005 14:00:00 2.5 1 5.3 0.4 2.3 1 4.9 0.4 1.6 1 4.6 0.4 302 39 340 255 0 0 0 0 21.3 0 21.7 21.1 05/10/2005 14:10:00 2.6 1 4.9 0.4 2.4 1.1 4.6 0.4 1.8 1.1 4.6 0.4 282 27 275 255 0 0 0 0 21.6 0 22 21.1 05/10/2005 14:20:00 3.3 1 6.1 0.7 3.1 1.1 5.3 0.7 2.6 1.1 5.3 0.4 309 21 298 255 0 0 0 0 21.2 0 21.4 21.1 05/10/2005 14:30:00 3.5 1.1 6.1 0.7 3.2 1.2 5.7 0.4 2.8 1.2 4.9 0.4 307 24 270 255 0 0 0 0 21 0 21.1 20.8 05/10/2005 14:40:00 2.6 1.2 4.9 0.4 2.4 1.2 5.3 0.4 2.1 1.2 5.3 0.4 294 32 284 255 0 0 0 0 21.2 0.1 22 20.8 05/10/2005 14:50:00 3.7 1.3 6.1 0.4 3.6 1.4 6.5 0.4 3.1 1.5 6.1 0.4 293 28 288 255 0 0 0 0 21.2 0.3 22 20.5 05/10/2005 15:00:00 3.2 1 6.1 0.7 3.1 1.1 5.7 0.4 2.6 1.1 6.1 0.4 297 30 278 255 0 0 0 0 21 0.2 21.4 20.5 05/10/2005 15:10:00 2.9 1.1 5.7 0.4 2.7 1.2 5.3 0.4 2.1 1.1 4.6 0.4 294 32 322 255 0 0 0 0 21.4 0.2 22 20.8 05/10/2005 15:20:00 3.4 1.3 6.5 0.4 3.2 1.3 6.1 0.4 2.5 1.1 5.7 0.4 294 33 304 255 0 0 0 0 21.7 0.1 22.3 21.1 05/10/2005 15:30:00 2.5 1.3 6.5 0.4 2.2 1.5 6.5 0.4 1.7 1.3 6.1 0.4 302 26 297 255 0 0 0 0 21.6 0.1 22 21.1 05/10/2005 15:40:00 3.2 1.7 6.5 0.4 3 1.8 6.1 0.4 2.6 1.7 6.1 0.4 298 22 307 255 0 0 0 0 21.7 0 22.3 21.4 05/10/2005 15:50:00 3.2 1.2 5.7 0.4 3.1 1.3 5.7 0.4 2.4 1.3 5.7 0.4 280 39 287 255 0 0 0 0 21.1 0 21.4 20.8 05/10/2005 16:00:00 3.4 1.1 6.1 0.4 3.3 1.1 5.7 0.7 2.6 1.3 5.7 0.4 282 23 298 255 0 0 0 0 21.3 0.2 21.7 20.8 05/10/2005 16:10:00 3.5 1 5.7 0.7 3.4 1 5.7 0.4 2.7 1.2 5.7 0.4 286 22 293 255 0 0 0 0 21 0 21.1 20.8 05/10/2005 16:20:00 3.9 1.1 5.7 1.1 3.7 1.1 6.1 0.7 3.3 1.3 6.1 0.4 290 24 274 255 0 0 0 0 20.5 0 21.1 20.3 05/10/2005 16:30:00 3.4 1.5 6.5 0.4 3.3 1.5 6.5 0.4 2.8 1.5 6.5 0.4 285 26 287 255 0 0 0 0 20.3 0 20.8 20.3 05/10/2005 16:40:00 3.1 1.2 5.7 0.7 2.9 1.2 5.3 0.4 2.2 1.3 6.1 0.4 287 27 301 255 0 0 0 0 20.3 0 20.5 20 05/10/2005 16:50:00 3.8 1.1 6.5 1.1 3.6 1.2 7.2 0.7 2.8 1.1 5.7 0.4 280 22 264 255 0 0 0 0 20.1 0 20.5 20 05/10/2005 17:00:00 3.2 1.1 5.7 0.4 3.1 1.1 5.3 0.4 2.3 1.2 4.9 0.4 277 26 314 255 0 0 0 0 20 0 20.3 20 05/10/2005 17:10:00 3.2 1.1 5.3 0.4 2.9 1.2 5.7 0.4 2.4 1.2 5.3 0.4 289 30 295 255 0 0 0 0 19.8 0 20 19.7 05/10/2005 17:20:00 2.6 1.1 5.7 0.4 2.4 1.2 5.7 0.4 1.9 1.2 5.3 0.4 279 38 257 255 0 0 0 0 19.5 0 20 19.4 05/10/2005 17:30:00 3.1 0.8 5.3 0.7 2.9 0.8 5.3 0.4 2.3 1 4.6 0.4 297 22 295 255 0 0 0 0 19.5 0 20 19.4 05/10/2005 17:40:00 3.5 1.2 6.1 0.4 3.4 1.2 6.1 0.4 2.7 1.2 5.7 0.4 278 22 275 255 0 0 0 0 19.4 0 20 19.1 05/10/2005 17:50:00 3.5 1 6.5 0.7 3.4 1 5.7 0.7 2.5 1.1 5.7 0.4 268 24 288 255 0 0 0 0 19.1 0.1 19.7 18.8 05/10/2005 18:00:00 3.2 1 5.7 0.7 3 1.1 5.7 0.4 2.2 1.2 5.3 0.4 284 26 270 255 0 0 0 0 19 0 19.4 18.8 05/10/2005 18:10:00 3.6 1 5.7 1.5 3.5 1 5.7 0.7 2.6 1.2 5.7 0.4 280 18 280 255 0 0 0 0 18.7 0 19.1 18.5 05/10/2005 18:20:00 3.2 1.1 5.7 0.4 2.9 1.2 5.3 0.4 2.5 1.1 4.9 0.4 289 22 301 255 0 0 0 0 18.6 0 19.1 18.5 05/10/2005 18:30:00 3.5 0.8 5.3 1.9 3.4 0.8 5.3 1.5 2.5 1 4.6 0.4 296 17 255 255 0 0 0 0 18.3 0 18.8 18.2 05/10/2005 18:40:00 2.7 1 5.7 0.7 2.5 1.1 5.7 0.4 1.7 1 4.6 0.4 279 26 255 255 0 0 0 0 18.1 0 18.2 18 05/10/2005 18:50:00 3.8 1 5.7 1.1 3.6 1 5.7 0.4 2.7 1.2 5.3 0.4 284 17 294 255 0 0 0 0 17.9 0 18.2 17.7 05/10/2005 19:00:00 3.4 1.2 6.1 0.4 3.2 1.2 5.7 0.4 2.5 1.3 5.7 0.4 283 22 299 255 0 0 0 0 17.7 0 17.7 17.4 05/10/2005 19:10:00 3.2 0.8 4.9 1.1 3 1 5.3 0.4 2.3 0.8 4.6 0.4 284 20 261 255 0 0 0 0 17.3 0 17.7 17.1 05/10/2005 19:20:00 3 1.3 5.7 0.4 2.8 1.4 5.3 0.4 2.2 1.1 4.9 0.4 276 23 281 255 0 0 0 0 17.2 0 17.4 17.1 05/10/2005 19:30:00 2.2 0.8 4.2 0.4 2 0.8 3.8 0.4 1.2 0.8 3.4 0.4 266 24 253 255 0 0 0 0 16.9 0 17.1 16.8 05/10/2005 19:40:00 2.6 0.9 4.9 0.4 2.5 1 5.3 0.4 1.8 1.1 4.2 0.4 259 21 279 255 0 0 0 0 16.6 0 16.8 16.6 05/10/2005 19:50:00 2.4 0.7 4.2 0.4 2.2 0.8 4.2 0.4 1.4 0.7 3.8 0.4 252 22 255 255 0 0 0 0 16.3 0.1 16.8 16 05/10/2005 20:00:00 1.7 0.8 3.8 0.4 1.4 0.9 3.8 0.4 0.8 0.6 2.6 0.4 250 18 260 255 0 0 0 0 15.9 0.1 16.6 15.7 05/10/2005 20:10:00 2.5 0.8 4.6 0.7 2.3 1 4.6 0.4 1.4 0.8 3.4 0.4 244 17 263 255 0 0 0 0 15.3 0.1 15.7 15.2 05/10/2005 20:20:00 1.9 0.5 3.4 0.4 1.7 0.6 3.4 0.4 0.9 0.5 2.3 0.4 237 13 281 255 0 0 0 0 14.7 0.2 15.5 14.4 05/10/2005 20:30:00 2.4 0.7 4.6 0.7 2.3 0.7 4.6 0.4 1.4 0.8 4.2 0.4 233 13 241 255 0 0 0 0 13.9 0 14.6 13.8 05/10/2005 20:40:00 2.4 0.6 4.2 1.1 2.2 0.6 3.8 0.7 1.1 0.6 3.8 0.4 235 15 235 255 0 0 0 0 13.7 0.1 14.4 13.3 05/10/2005 20:50:00 2.5 0.7 4.6 1.1 2.3 0.7 4.2 0.4 1.3 0.6 3.4 0.4 232 16 234 255 0 0 0 0 13 0.2 13.3 12.7 05/10/2005 21:00:00 1.9 0.6 4.2 0.4 1.6 0.7 3.8 0.4 0.8 0.6 3 0.4 250 15 253 255 0 0 0 0 12.7 0.2 13.3 12.2 05/10/2005 21:10:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 285 19 284 255 0 0 0 0 11.9 0.2 12.7 11.7 05/10/2005 21:20:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.9 0.4 281 18 257 255 0 0 0 0 11.1 0.2 11.7 10.6 05/10/2005 21:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 6 323 255 0 0 0 0 10.5 0 11.1 10.3 05/10/2005 21:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 348 0 348 255 0 0 0 0 10.1 0.1 10.6 9.6 05/10/2005 21:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 337 38 270 255 0 0 0 0 9.5 0 10.1 9.3 05/10/2005 22:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 278 39 268 255 0 0 0 0 9.2 0.1 9.8 9 05/10/2005 22:10:00 1.2 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 342 16 8 255 0 0 0 0 8.7 0.1 9.6 8.5 05/10/2005 22:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 329 255 0 0 0 0 8.5 0.1 9 8.3 05/10/2005 22:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 276 45 329 255 0 0 0 0 8.3 0.2 8.8 8 05/10/2005 22:40:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 231 3 227 255 0 0 0 0 8 0 8.5 7.8 05/10/2005 22:50:00 1.2 0.4 2.6 0.4 0.9 0.5 3 0.4 0.4 0.2 1.5 0.4 219 10 218 255 0 0 0 0 7.6 0.2 8.3 7.3 05/10/2005 23:00:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 196 8 204 255 0 0 0 0 7.2 0 7.8 7 05/10/2005 23:10:00 1.6 0.4 2.6 0.7 1.9 0.4 3 0.4 1.1 0.5 2.3 0.4 182 3 182 255 0 0 0 0 6.9 0.1 7.5 6.7 05/10/2005 23:20:00 1.5 0.3 2.6 0.7 2 0.2 2.6 1.5 1 0.4 1.9 0.4 179 3 181 255 0 0 0 0 6.7 0 7 6.5 05/10/2005 23:30:00 1.3 0.3 1.9 0.7 1.7 0.3 2.3 1.1 0.5 0.3 1.5 0.4 175 1 178 255 0 0 0 0 6.3 0.1 7 6.2 05/10/2005 23:40:00 1.5 0.4 2.6 0.7 2.2 0.3 2.6 1.1 1.2 0.6 2.3 0.4 175 3 178 255 0 0 0 0 6.2 0 6.7 6 05/10/2005 23:50:00 2.6 0.5 3.4 1.1 2.9 0.3 3.4 2.3 2 0.4 2.6 1.1 168 7 163 255 0 0 0 0 6.2 0 6.2 6 05/11/2005 00:00:00 2.6 0.4 3.4 1.5 2.8 0.4 3.4 1.5 1.7 0.5 3 0.4 164 5 158 255 0 0 0 0 6.1 0 6.5 5.7 05/11/2005 00:10:00 0.7 0.6 2.6 0.4 0.6 0.6 2.6 0.4 0.4 0.1 1.1 0.4 163 1 164 255 0 0 0 0 5.4 0.2 6 5 05/11/2005 00:20:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0 0.4 0.4 161 13 183 255 0 0 0 0 5.1 0 5.5 5 05/11/2005 00:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 147 0 147 255 0 0 0 0 4.8 0.1 5.5 4.8 05/11/2005 00:40:00 1.6 0.7 2.6 0.4 1.5 0.8 3 0.4 0.7 0.5 1.9 0.4 163 8 168 255 0 0 0 0 4.6 0.1 5.2 4.5 05/11/2005 00:50:00 2.4 0.4 3 1.5 2.8 0.4 3.4 1.5 1.6 0.5 2.6 0.4 169 7 162 255 0 0 0 0 4.5 0 5 4.3 05/11/2005 01:00:00 1.8 0.4 3 1.1 2.9 0.3 3.4 2.3 1.7 0.2 2.3 0.7 175 4 182 255 0 0 0 0 4.8 0 4.8 4.5 05/11/2005 01:10:00 2.5 0.4 3.4 1.5 2.7 0.3 3 1.9 1.4 0.4 2.3 0.4 162 5 158 255 0 0 0 0 4.6 0 4.8 4.3 05/11/2005 01:20:00 2.2 0.4 3 1.1 2.6 0.3 3.4 1.9 1.3 0.4 2.3 0.4 167 5 165 255 0 0 0 0 4.1 0.1 4.5 4 05/11/2005 01:30:00 3.2 0.4 4.2 1.9 3.3 0.4 4.2 1.9 1.9 0.4 3 0.4 162 5 164 255 0 0 0 0 4 0 4 3.8 05/11/2005 01:40:00 2.6 0.4 3.4 1.9 2.7 0.5 3.8 1.5 1.4 0.6 2.6 0.4 159 6 171 255 0 0 0 0 4 0 4 3.8 05/11/2005 01:50:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 1.3 0.5 2.6 0.4 140 8 146 255 0 0 0 0 3.8 0 4 3.5 05/11/2005 02:00:00 3.3 0.5 4.6 2.3 3.3 0.6 4.6 1.9 2 0.6 3.4 0.4 137 6 134 255 0 0 0 0 3.5 0 3.8 3.3 05/11/2005 02:10:00 3.3 0.5 4.6 1.5 3.3 0.5 4.2 1.5 2 0.6 3.4 0.4 134 8 146 255 0 0 0 0 3.6 0 3.8 3.5 05/11/2005 02:20:00 2.5 0.5 3.4 1.5 2.4 0.6 3.4 1.1 1.2 0.4 2.3 0.4 135 5 140 255 0 0 0 0 3.3 0 3.5 3.3 05/11/2005 02:30:00 2.2 0.4 3 1.5 2.1 0.4 3 1.1 1.1 0.4 2.3 0.4 136 7 132 255 0 0 0 0 3.2 0.1 3.3 2.8 05/11/2005 02:40:00 2.1 0.5 3.8 1.1 1.9 0.6 3.4 0.7 1.1 0.5 2.6 0.4 139 7 131 255 0 0 0 0 2.9 0 3 2.8 05/11/2005 02:50:00 2.5 0.5 3.8 1.1 2.4 0.5 3.4 1.1 1.6 0.5 2.6 0.4 138 11 138 255 0 0 0 0 2.7 0 2.8 2.6 05/11/2005 03:00:00 1.4 0.6 2.6 0.4 1.2 0.7 3 0.4 0.6 0.5 1.9 0.4 137 9 145 255 0 0 0 0 2.5 0 2.8 2.3 05/11/2005 03:10:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 85 23 104 255 0 0 0 0 2.6 0 2.8 2.6 05/11/2005 03:20:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 93 17 113 255 0 0 0 0 2.5 0.1 2.8 2.3 05/11/2005 03:30:00 1 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 93 10 88 255 0 0 0 0 2.3 0 2.6 2.3 05/11/2005 03:40:00 2.4 0.8 3.8 0.7 2.2 0.9 3.8 0.4 1.1 0.7 2.6 0.4 112 5 117 255 0 0 0 0 2.3 0 2.3 2.1 05/11/2005 03:50:00 3.4 0.6 4.6 1.9 3.3 0.6 4.6 1.5 2 0.5 3.4 0.7 121 11 110 255 0 0 0 0 2.3 0 2.6 2.1 05/11/2005 04:00:00 3.1 0.6 4.6 1.9 3 0.6 4.2 1.5 2.1 0.6 3.8 0.4 127 11 106 255 0 0 0 0 2.7 0.2 3.3 2.3 05/11/2005 04:10:00 2.9 0.8 4.9 1.5 2.8 0.9 4.9 0.4 1.8 0.7 3.8 0.4 126 13 134 255 0 0 0 0 3.2 0.1 3.5 2.8 05/11/2005 04:20:00 2.2 0.5 3.8 1.1 2 0.5 3.4 0.7 1.3 0.6 3 0.4 123 12 119 255 0 0 0 0 3 0.1 3.5 2.8 05/11/2005 04:30:00 2.5 0.6 3.8 1.1 2.3 0.7 3.8 0.7 1.3 0.6 3.4 0.4 122 12 117 255 0 0 0 0 3.2 0.1 3.5 2.8 05/11/2005 04:40:00 2.4 0.6 3.8 1.1 2.2 0.7 3.8 0.4 1.1 0.5 2.3 0.4 117 11 117 255 0 0 0 0 3 0 3.3 2.8 05/11/2005 04:50:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 0.7 1.1 0.5 2.6 0.4 115 12 105 255 0 0 0 0 3 0 3.3 2.8 05/11/2005 05:00:00 2.4 0.6 4.2 1.1 2.2 0.7 3.8 0.4 1.1 0.6 2.6 0.4 112 11 109 255 0 0 0 0 3.1 0 3.3 2.8 05/11/2005 05:10:00 2.5 0.6 3.8 0.7 2.3 0.6 3.4 0.7 1.1 0.6 2.6 0.4 113 13 118 255 0 0 0 0 3.5 0.1 4 3.3 05/11/2005 05:20:00 2.4 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.1 0.6 2.6 0.4 118 12 110 255 0 0 0 0 3.9 0.1 4.5 3.8 05/11/2005 05:30:00 2.6 0.6 3.8 0.7 2.4 0.7 3.8 0.4 1.5 0.7 3 0.4 105 11 109 255 0 0 0 0 4.8 0.3 5.5 4.3 05/11/2005 05:40:00 2.7 0.5 3.8 1.1 2.5 0.5 3.8 0.7 1.5 0.6 3 0.4 102 10 96 255 0 0 0 0 5.9 0.3 6.7 5.5 05/11/2005 05:50:00 2.3 0.5 3.4 0.7 2 0.6 3.8 0.4 1 0.6 2.6 0.4 101 9 108 255 0 0 0 0 7.3 0.4 7.8 6.7 05/11/2005 06:00:00 2.2 0.5 3.4 1.1 2 0.5 3 0.7 1.3 0.5 2.6 0.4 103 9 101 255 0 0 0 0 8.1 0.1 8.5 7.8 05/11/2005 06:10:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 1.1 1.5 0.6 3.4 0.4 101 11 92 255 0 0 0 0 8.7 0.2 9 8.5 05/11/2005 06:20:00 2.1 0.6 3.8 0.7 1.9 0.8 3.8 0.4 1.3 0.7 3 0.4 102 15 91 255 0 0 0 0 9.4 0.2 9.8 9 05/11/2005 06:30:00 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 0.9 0.6 2.6 0.4 92 14 88 255 0 0 0 0 10.3 0.1 10.6 9.8 05/11/2005 06:40:00 1.7 0.6 3 0.4 1.5 0.7 3 0.4 1 0.7 2.6 0.4 95 14 90 255 0 0 0 0 10.6 0 11.1 10.6 05/11/2005 06:50:00 1.9 0.5 3.4 0.7 1.7 0.6 3 0.4 1 0.6 2.6 0.4 95 17 100 255 0 0 0 0 11.1 0.3 11.7 10.6 05/11/2005 07:00:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 1 0.6 2.6 0.4 87 21 118 255 0 0 0 0 11.7 0.2 12.5 11.4 05/11/2005 07:10:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1 0.5 2.6 0.4 74 14 59 255 0 0 0 0 12.5 0.2 13 11.9 05/11/2005 07:20:00 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 70 19 84 255 0 0 0 0 12.9 0.1 13.5 12.7 05/11/2005 07:30:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 71 10 73 255 0 0 0 0 13.3 0.1 13.8 13 05/11/2005 07:40:00 1.9 0.6 3 0.4 1.7 0.7 3 0.4 1.4 0.7 3 0.4 68 16 90 255 0 0 0 0 13.7 0 14.4 13.5 05/11/2005 07:50:00 2.3 0.5 3.4 1.1 2 0.5 3.4 0.7 1.6 0.6 3.4 0.4 39 15 31 255 0 0 0 0 14.4 0.2 15.2 13.8 05/11/2005 08:00:00 1.9 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.3 0.8 3 0.4 44 20 68 255 0 0 0 0 14.9 0 15.5 14.6 05/11/2005 08:10:00 1.7 0.6 3.4 0.4 1.4 0.6 3 0.4 1.2 0.6 2.3 0.4 47 17 44 255 0 0 0 0 15 0 15.5 14.9 05/11/2005 08:20:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 52 22 52 255 0 0 0 0 15.5 0.1 16 15.2 05/11/2005 08:30:00 1.8 0.9 3.4 0.4 1.5 1 3.8 0.4 1.2 0.8 3.8 0.4 62 28 48 255 0 0 0 0 15.9 0 16.3 15.7 05/11/2005 08:40:00 2.4 0.5 3.8 0.7 2.3 0.6 3.8 0.4 1.9 0.6 3.4 0.4 37 14 49 255 0 0 0 0 16.5 0.2 16.8 16 05/11/2005 08:50:00 2.1 0.5 3 0.7 1.8 0.6 3 0.4 1.6 0.6 3.4 0.4 37 18 60 255 0 0 0 0 16.8 0.2 17.1 16.6 05/11/2005 09:00:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 18 13 23 255 0 0 0 0 17.5 0 17.7 17.1 05/11/2005 09:10:00 1.3 0.5 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 9 20 22 255 0 0 0 0 18.3 0.4 19.4 17.7 05/11/2005 09:20:00 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 14 39 343 255 0 0 0 0 18.9 0 19.4 18.5 05/11/2005 09:30:00 1.9 0.5 3 0.4 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 4 15 345 255 0 0 0 0 19.1 0.2 20 18.5 05/11/2005 09:40:00 2 0.6 3.8 0.4 1.8 0.7 3.4 0.4 1.1 0.8 3 0.4 8 22 9 255 0 0 0 0 19.7 0.1 20.3 19.4 05/11/2005 09:50:00 1.9 0.6 3.8 0.4 1.7 0.7 4.2 0.4 1.2 0.7 3.4 0.4 11 18 10 255 0 0 0 0 19.9 0 20.5 19.7 05/11/2005 10:00:00 2.4 0.7 3.8 0.7 2.2 0.8 3.8 0.4 1.8 0.8 3.8 0.4 25 22 18 255 0 0 0 0 20.1 0.1 20.5 20 05/11/2005 10:10:00 2.6 0.5 3.8 1.5 2.5 0.5 3.4 1.1 1.9 0.7 3.4 0.4 43 18 55 255 0 0 0 0 20.3 0.1 21.1 20 05/11/2005 10:20:00 2 0.9 4.2 0.4 1.8 1 3.8 0.4 1.5 0.8 3.4 0.4 26 32 7 255 0 0 0 0 20.5 0.3 21.1 20 05/11/2005 10:30:00 2.2 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.6 0.8 3.4 0.4 30 17 20 255 0 0 0 0 21.1 0 21.1 20.8 05/11/2005 10:40:00 2 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.3 0.8 3.4 0.4 63 36 43 255 0 0 0 0 21 0.2 21.4 20.5 05/11/2005 10:50:00 2.6 0.9 5.3 1.1 2.5 1 5.3 0.4 2.1 0.9 4.6 0.4 39 30 22 255 0 0 0 0 21.3 0 21.7 20.8 05/11/2005 11:00:00 2.4 0.9 4.6 0.4 2.2 1 4.2 0.4 1.8 0.9 4.2 0.4 18 19 25 255 0 0 0 0 22 0 22.3 21.7 05/11/2005 11:10:00 2.9 0.9 5.7 1.5 2.7 0.9 5.3 0.7 2.1 1 4.9 0.4 25 19 21 255 0 0 0 0 22.3 0.1 22.9 22 05/11/2005 11:20:00 3.3 0.7 4.9 0.7 3.2 0.8 4.9 0.7 2.5 0.8 4.2 0.4 29 22 23 255 0 0 0 0 22.3 0.1 23.2 22 05/11/2005 11:30:00 3.3 0.7 4.9 1.1 3.2 0.7 4.6 1.1 2.6 0.7 3.8 0.7 47 18 34 255 0 0 0 0 22.1 0 22.3 22 05/11/2005 11:40:00 2.8 0.8 5.3 0.4 2.7 1 5.7 0.4 1.9 1 4.2 0.4 11 19 70 255 0 0 0 0 23 0.3 23.5 22.3 05/11/2005 11:50:00 3.9 1 6.1 1.9 3.8 1 6.1 1.1 3.3 1 6.1 0.7 43 18 40 255 0 0 0 0 23 0 23.5 22.9 05/11/2005 12:00:00 3.5 1 6.5 1.1 3.3 1.1 6.5 0.7 2.8 1.2 5.7 0.4 24 32 64 255 0 0 0 0 23 0 23.5 22.6 05/11/2005 12:10:00 4.2 1 6.5 1.1 4 1.2 6.8 0.4 3.2 1.1 5.7 0.7 14 30 73 255 0 0 0 0 23.3 0.2 23.8 22.9 05/11/2005 12:20:00 4.1 1.1 6.8 1.5 3.8 1.2 7.2 0.7 2.7 1.2 6.5 0.7 355 19 12 255 0 0 0 0 24.3 0 24.7 23.8 05/11/2005 12:30:00 4.2 1.3 7.6 1.9 4.1 1.4 8 1.5 3.2 1.4 6.5 0.4 8 24 14 255 0 0 0 0 24.2 0.2 24.7 23.8 05/11/2005 12:40:00 5.7 1 8.4 3.4 5.6 1.1 8.8 3 4.4 1.2 7.6 1.1 28 27 348 255 0 0 0 0 24.2 0 24.4 24.1 05/11/2005 12:50:00 5.1 1.3 8 1.5 4.9 1.4 8.4 1.1 3.9 1.5 7.2 0.4 6 18 344 255 0 0 0 0 24.5 0.2 25 24.1 05/11/2005 13:00:00 4.8 1.3 8.4 1.9 4.8 1.4 8.8 1.5 4 1.2 7.2 1.1 26 21 4 255 0 0 0 0 24.5 0.1 25 24.1 05/11/2005 13:10:00 5.6 1.1 8.4 3.4 5.5 1.2 8.4 3 4 1.5 8.4 0.7 2 13 7 255 0 0 0 0 24.8 0 25 24.7 05/11/2005 13:20:00 5.2 1 7.6 3 5 1 7.2 2.6 4.2 1.1 7.2 0.7 26 20 42 255 0 0 0 0 25 0 25.3 25 05/11/2005 13:30:00 5 1.4 8 1.1 4.8 1.5 8 1.5 3.7 1.5 7.6 0.4 8 29 17 255 0 0 0 0 25.2 0.1 25.6 24.7 05/11/2005 13:40:00 5.9 1 9.1 2.6 5.8 1.1 8.8 2.6 4.4 1.2 6.8 1.1 14 16 11 255 0 0 0 0 24.1 0.5 25.3 23.5 05/11/2005 13:50:00 5.5 0.9 7.6 2.6 5.4 1 8 2.6 4.1 1.2 7.2 1.1 11 16 19 255 0 0 0 0 23.8 0.1 24.1 23.5 05/11/2005 14:00:00 6.3 1.2 9.1 2.3 6.1 1.3 9.1 1.9 4.4 1.6 7.6 0.4 5 16 355 255 0 0 0 0 23.5 0 23.8 23.5 05/11/2005 14:10:00 4.9 1.3 8 1.5 4.8 1.3 8 1.5 3.6 1.4 6.8 0.4 12 20 18 255 0 0 0 0 24 0.4 25 23.5 05/11/2005 14:20:00 6.3 1.1 9.5 2.6 6.2 1.2 9.5 1.5 4.8 1.3 8 1.5 14 17 22 255 0 0 0 0 24.8 0.3 25.3 23.8 05/11/2005 14:30:00 5.2 1 7.2 2.6 5.1 1 7.6 2.3 4 1.3 6.5 0.4 21 17 3 255 0 0 0 0 23.6 0 24.1 23.5 05/11/2005 14:40:00 5 1.1 7.6 2.3 4.9 1.1 7.6 1.9 4 1.2 6.8 1.1 21 12 18 255 0 0 0 0 24.2 0.4 25 23.5 05/11/2005 14:50:00 4.2 1.1 7.6 1.9 4.1 1.1 8 1.5 3 1.2 7.2 0.4 20 22 55 255 0 0 0 0 25.2 0 25.3 25 05/11/2005 15:00:00 4.1 1.5 7.2 0.4 4 1.5 7.2 0.4 3.2 1.5 6.5 0.4 37 19 47 255 0 0 0 0 25 0.1 25.6 25 05/11/2005 15:10:00 5.9 1.2 8.8 3.4 5.8 1.2 8.8 2.6 4.3 1.3 8 1.9 7 20 25 255 0 0 0 0 25.3 0 25.6 25 05/11/2005 15:20:00 6.3 1.2 8.8 2.6 6.2 1.2 8.4 2.3 4.9 1.6 8.4 0.7 21 17 12 255 0 0 0 0 25.1 0.1 25.3 25 05/11/2005 15:30:00 5.9 1.1 9.5 3 5.8 1.1 9.5 2.6 4.7 1.2 8 1.5 26 17 34 255 0 0 0 0 24.9 0.1 25.3 24.7 05/11/2005 15:40:00 6.2 1.1 9.1 3.4 6.1 1.1 8.8 3 5 1.1 7.6 2.3 36 19 23 255 0 0 0 0 24.9 0.2 25.3 24.4 05/11/2005 15:50:00 7.2 1 9.9 4.2 7.1 1.1 10.3 4.2 5.6 1.5 8.8 0.7 24 21 46 255 0 0 0 0 24.7 0.1 25.3 24.4 05/11/2005 16:00:00 6.2 1 9.5 3.4 6.2 1 9.1 3.8 5.1 1.2 8 1.9 31 17 17 255 0 0 0 0 24.8 0.2 25.3 24.7 05/11/2005 16:10:00 5.7 1.3 8.8 1.5 5.6 1.3 8.8 1.5 4.3 1.5 7.2 0.7 14 16 359 255 0 0 0 0 24.7 0.1 25.3 24.4 05/11/2005 16:20:00 5.6 1.2 8.4 3 5.5 1.2 8.8 2.6 4.1 1.5 7.6 1.1 18 18 36 255 0 0 0 0 23.9 0.4 24.4 23.5 05/11/2005 16:30:00 6.4 1.5 9.5 2.6 6.3 1.5 9.5 2.6 5.2 1.6 8.8 1.1 21 13 13 255 0 0 0 0 23 0.2 23.5 22.9 05/11/2005 16:40:00 6.2 1.2 9.1 3.4 6.1 1.2 9.1 3.4 5.1 1.5 8.8 1.1 18 12 20 255 0 0 0 0 22.3 0 22.9 22 05/11/2005 16:50:00 6.2 1 9.1 3.8 6.2 1 9.1 3 4.8 1.1 7.2 1.5 7 12 2 255 0 0 0 0 21.9 0 22.3 21.7 05/11/2005 17:00:00 5.8 1 8.4 3.4 5.8 1 8 3.4 4.3 1.3 7.2 0.7 15 12 16 255 0 0 0 0 21.9 0 22.6 21.7 05/11/2005 17:10:00 5.5 1.1 9.1 1.9 5.5 1.1 9.5 2.6 4.1 1.3 8 1.5 15 13 353 255 0 0 0 0 21.9 0 22.3 21.7 05/11/2005 17:20:00 5.9 1.4 9.5 1.5 5.8 1.4 9.5 1.5 4.5 1.7 9.1 0.4 23 22 25 255 0 0 0 0 22 0 22.3 21.7 05/11/2005 17:30:00 6 1.5 10.3 2.6 5.9 1.5 9.9 2.3 4.4 1.7 9.1 1.1 17 19 13 255 0 0 0 0 21.9 0 22 21.7 05/11/2005 17:40:00 6.3 1.2 9.5 3 6.3 1.3 9.5 3.4 4.8 1.5 8.4 1.1 17 13 6 255 0 0 0 0 21.4 0.1 21.7 21.1 05/11/2005 17:50:00 5.6 1.3 8.8 2.6 5.5 1.3 9.1 2.6 4.3 1.5 9.1 0.7 20 15 17 255 0 0 0 0 21 0 21.4 20.8 05/11/2005 18:00:00 5.7 1 9.5 3.4 5.6 1 9.5 3 4.2 1.3 7.6 0.7 14 15 13 255 0 0 0 0 20.6 0 21.1 20.5 05/11/2005 18:10:00 5.6 1.1 8.4 2.6 5.6 1.1 8.4 2.6 4.2 1.4 7.6 1.1 14 13 29 255 0 0 0 0 20.5 0 21.1 20.5 05/11/2005 18:20:00 6.6 1 9.1 4.6 6.5 1.1 9.1 4.2 5.2 1.3 8.4 1.9 15 13 12 255 0 0 0 0 20.7 0.2 21.1 20.5 05/11/2005 18:30:00 5.4 1.3 9.1 2.3 5.3 1.4 8.8 1.9 3.7 1.5 8 0.4 8 16 1 255 0 0 0 0 21 0 21.4 20.8 05/11/2005 18:40:00 6.5 1.2 9.1 3.4 6.4 1.2 9.1 3.4 5 1.5 8.4 0.7 12 11 14 255 0 0 0 0 21 0.1 21.4 20.8 05/11/2005 18:50:00 6.3 1 8.8 4.2 6.2 1 8.8 4.2 5.1 1.2 8 1.9 20 12 22 255 0 0 0 0 20.7 0 21.1 20.5 05/11/2005 19:00:00 6.6 1.2 9.5 3.8 6.5 1.2 9.1 4.2 5.1 1.4 8.8 2.3 19 12 13 255 0 0 0 0 20.5 0 21.1 20.5 05/11/2005 19:10:00 6.6 1.4 9.9 3 6.5 1.4 9.9 3 5.2 1.5 9.5 1.9 23 13 17 255 0 0 0 0 20.1 0 20.8 19.7 05/11/2005 19:20:00 5.9 1.5 11.1 3 5.8 1.5 11.1 3 4.8 1.5 10.7 2.3 20 11 15 255 0 0 0 0 19.5 0.1 20.3 19.4 05/11/2005 19:30:00 5.5 1.1 8.4 1.9 5.4 1.2 8.4 1.5 3.8 1.5 6.8 0.4 15 15 27 255 0 0 0 0 19.1 0 19.4 18.8 05/11/2005 19:40:00 5.1 1 8 2.6 5.1 1 8.4 2.6 3.6 1 7.2 1.1 11 14 3 255 0 0 0 0 18.8 0 19.1 18.5 05/11/2005 19:50:00 4.9 1.3 8 1.5 4.7 1.4 8.4 1.1 3.4 1.5 6.8 0.4 2 15 352 255 0 0 0 0 18.5 0 18.5 18.2 05/11/2005 20:00:00 4 1.1 6.5 1.1 3.9 1.1 6.8 1.1 2.7 1.2 5.3 0.4 9 14 350 255 0 0 0 0 18.4 0 18.5 18.2 05/11/2005 20:10:00 4.5 0.8 6.5 2.3 4.4 0.8 6.5 2.3 2.9 1.1 6.1 0.4 13 13 37 255 0 0 0 0 18.3 0 18.2 18.2 05/11/2005 20:20:00 4.9 1 7.2 2.3 4.8 1 7.2 1.5 3.3 1.3 6.1 0.4 12 13 3 255 0 0 0 0 18 0 18.2 17.7 05/11/2005 20:30:00 3 1.2 7.6 1.1 2.8 1.3 7.2 0.4 1.8 1.3 5.7 0.4 1 17 16 255 0 0 0 0 17.7 0 18 17.4 05/11/2005 20:40:00 3.6 1 6.5 1.5 3.5 1 6.5 1.1 2.6 1.2 5.3 0.4 15 17 34 255 0 0 0 0 17.6 0 17.7 17.4 05/11/2005 20:50:00 4.9 1 7.2 2.3 4.8 1.1 7.2 2.3 3.7 1.2 8 0.7 20 13 18 255 0 0 0 0 17.7 0 17.7 17.4 05/11/2005 21:00:00 4.8 0.9 8.4 2.6 4.7 1 8.4 2.3 3.6 1 6.5 1.1 25 15 10 255 0 0 0 0 17.8 0 18 17.7 05/11/2005 21:10:00 5.2 0.9 8.8 3 5.1 1 8.8 2.6 3.6 1.2 7.6 1.1 11 11 13 255 0 0 0 0 17.8 0 18 17.4 05/11/2005 21:20:00 4.1 0.7 6.5 2.6 4.1 0.7 6.5 2.3 3 0.8 4.9 0.4 13 12 19 255 0 0 0 0 17.4 0.1 17.7 17.1 05/11/2005 21:30:00 3.7 0.8 5.3 1.5 3.6 0.8 5.3 0.4 2.7 1 5.3 0.4 18 11 2 255 0 0 0 0 17.3 0 17.4 17.1 05/11/2005 21:40:00 2.6 0.6 4.2 1.5 2.5 0.6 3.8 1.1 1.7 0.9 3.4 0.4 61 24 82 255 0 0 0 0 17.1 0 17.1 16.8 05/11/2005 21:50:00 3.4 1.1 6.8 1.1 3.2 1.1 6.8 0.4 2.4 1 5.7 0.4 58 19 46 255 0 0 0 0 16.5 0 16.8 16.3 05/11/2005 22:00:00 4.3 1.2 7.6 1.9 4.1 1.3 7.2 1.5 3 1.3 7.2 0.4 49 20 26 255 0 0 0 0 16.4 0.1 16.8 16 05/11/2005 22:10:00 3.3 0.7 5.3 1.5 3.2 0.7 4.9 1.1 2.4 0.8 4.2 0.7 56 15 36 255 0 0 0 0 15.7 0.2 16.3 15.5 05/11/2005 22:20:00 3.6 1 6.5 1.1 3.5 1 6.5 1.5 2.8 1.1 6.5 0.7 39 14 11 255 0 0 0 0 15.4 0 15.7 15.2 05/11/2005 22:30:00 4.2 1.1 7.2 1.5 4.1 1.2 7.2 1.1 2.9 1.2 6.1 0.4 14 17 36 255 0 0 0 0 15.2 0.1 15.7 14.9 05/11/2005 22:40:00 5.7 1.2 9.1 2.3 5.6 1.2 9.1 1.9 4.3 1.3 7.6 1.1 21 15 23 255 0 0 0 0 15.2 0.3 16.3 14.9 05/11/2005 22:50:00 5.3 1 8 2.6 5.2 1 7.6 2.6 4.2 1.1 6.8 1.1 28 15 10 255 0 0 0 0 16.1 0 16.6 15.7 05/11/2005 23:00:00 5.2 1.1 8 3 5.1 1.1 7.6 2.6 4.1 1.1 7.2 1.1 29 14 30 255 0 0 0 0 16.1 0 16.6 16 05/11/2005 23:10:00 5.4 1.1 9.1 3 5.4 1.1 9.1 3 4.4 1.1 8.4 1.5 28 12 26 255 0 0 0 0 16.1 0 16.6 16 05/11/2005 23:20:00 6.4 0.9 8.8 3.4 6.3 1 9.1 3.4 5.3 1.2 8.8 2.3 28 12 51 255 0 0 0 0 16.1 0 16.6 16 05/11/2005 23:30:00 6 1.3 9.5 3 6 1.3 9.5 2.6 4.9 1.6 8.8 1.5 26 12 37 255 0 0 0 0 16.1 0 16.6 16 05/11/2005 23:40:00 5.5 0.9 7.6 2.6 5.4 0.9 7.6 3 4.4 0.9 6.5 1.9 31 13 62 255 0 0 0 0 15.9 0 16.6 15.7 05/11/2005 23:50:00 5.7 1 8.8 3 5.6 1 8.4 2.6 4.5 1.1 8.4 1.9 34 13 41 255 0 0 0 0 15.7 0 16.3 15.7 05/12/2005 00:00:00 6 1.1 9.5 3 5.9 1.1 9.5 3 4.7 1.1 8 2.3 32 13 27 255 0 0 0 0 15.6 0 16.3 15.5 05/12/2005 00:10:00 6.8 1.3 9.9 3.4 6.7 1.3 9.9 4.2 5.6 1.4 9.1 1.9 25 11 5 255 0 0 0 0 15.6 0 16 15.5 05/12/2005 00:20:00 6.1 1.1 8.8 3 6 1.2 8.8 3 4.8 1.2 8 2.3 27 13 8 255 0 0 0 0 15.5 0 16 15.5 05/12/2005 00:30:00 4.8 1 7.2 2.3 4.7 1.1 7.6 2.3 3.7 1 6.8 1.5 44 13 45 255 0 0 0 0 15.3 0.1 15.7 15.2 05/12/2005 00:40:00 5.7 1.2 8.8 2.6 5.6 1.2 8.8 2.6 4.7 1.1 8 2.3 53 17 76 255 0 0 0 0 15 0 15.5 14.6 05/12/2005 00:50:00 5.1 1.3 9.5 2.6 5.1 1.3 8.8 2.3 4.1 1.5 8.8 1.1 34 14 47 255 0 0 0 0 14.6 0 15.2 14.4 05/12/2005 01:00:00 4.8 1.2 8.4 1.9 4.8 1.3 8.4 1.5 3.7 1.1 6.5 1.1 57 15 50 255 0 0 0 0 14.4 0 14.9 14.4 05/12/2005 01:10:00 5 1 8 2.3 4.9 1 7.6 2.3 4.2 1 6.5 1.5 38 15 72 255 0 0 0 0 14.4 0 14.9 14.4 05/12/2005 01:20:00 5.1 1 8.8 2.6 5.1 1 8.4 2.6 4.2 1 7.6 1.5 50 15 42 255 0 0 0 0 14.4 0 14.9 14.4 05/12/2005 01:30:00 4.4 1.3 8 1.5 4.3 1.3 8.4 1.1 3.5 1.3 6.8 0.4 45 16 56 255 0 0 0 0 14.2 0.1 14.6 13.8 05/12/2005 01:40:00 5.9 1.2 9.5 3 5.8 1.2 9.1 3 4.6 1.1 8.8 1.9 44 14 30 255 0 0 0 0 13.9 0.1 14.6 13.8 05/12/2005 01:50:00 5.8 1.1 9.5 3.4 5.8 1.2 9.5 3 4.8 1.2 8 1.9 39 14 27 255 0 0 0 0 13.9 0.1 14.6 13.8 05/12/2005 02:00:00 5.4 1.1 8.4 2.3 5.3 1.1 8.8 2.6 4.2 1.2 8.8 1.1 45 17 32 255 0 0 0 0 13.9 0 14.6 13.8 05/12/2005 02:10:00 6.2 1.2 9.1 3 6.2 1.3 9.1 2.6 5 1.3 9.1 2.3 44 14 37 255 0 0 0 0 13.9 0 14.1 13.8 05/12/2005 02:20:00 5.6 1.2 9.5 2.6 5.4 1.3 9.9 2.3 4.2 1.3 8.8 0.7 57 17 68 255 0 0 0 0 13.7 0 14.1 13.5 05/12/2005 02:30:00 4.8 1.1 8.4 1.9 4.7 1.2 8.4 1.9 3.7 1.2 7.2 0.7 64 17 45 255 0 0 0 0 13.5 0 14.1 13.3 05/12/2005 02:40:00 6.6 1.3 10.7 3.8 6.6 1.4 10.3 3.4 5.3 1.5 9.1 1.9 51 15 62 255 0 0 0 0 13.5 0 13.8 13.3 05/12/2005 02:50:00 5.8 1.2 9.1 2.6 5.8 1.3 9.1 2.3 4.7 1.2 8 1.9 64 17 66 255 0 0 0 0 13.4 0 13.8 13 05/12/2005 03:00:00 6.8 1.5 11.5 2.6 6.8 1.6 11.5 3 5.4 1.3 8.4 1.5 55 15 52 255 0 0 0 0 13.1 0 13.5 13 05/12/2005 03:10:00 6.6 1.5 10.7 2.3 6.5 1.5 10.3 2.6 5.3 1.6 9.9 1.9 53 15 47 255 0 0 0 0 13.1 0 13.5 13 05/12/2005 03:20:00 5.2 1.9 10.7 1.9 5.1 1.9 10.3 1.9 4 1.9 8.8 0.4 62 21 52 255 0 0 0 0 12.8 0 13 12.5 05/12/2005 03:30:00 4.8 1.2 8.4 2.6 4.7 1.2 8 1.9 3.9 1.4 7.6 0.4 72 17 71 255 0 0 0 0 12.4 0 13 12.2 05/12/2005 03:40:00 5.8 1.1 8.4 3 5.8 1.2 8.4 2.6 4.8 1.2 8.8 1.5 68 17 80 255 0 0 0 0 12.3 0 12.7 12.2 05/12/2005 03:50:00 6.4 1.3 9.9 3 6.3 1.4 9.9 3 5.1 1.5 9.5 1.5 64 18 65 255 0 0 0 0 12.5 0 12.7 12.2 05/12/2005 04:00:00 6.7 1.1 9.5 3.4 6.8 1.2 9.9 3.8 5.7 1.3 9.1 1.9 61 13 55 255 0 0 0 0 12.4 0 12.7 12.2 05/12/2005 04:10:00 6.6 1.4 10.7 3.8 6.6 1.4 10.7 3.4 5.4 1.5 9.5 1.5 58 17 79 255 0 0 0 0 12.3 0 12.7 12.2 05/12/2005 04:20:00 6.5 1.5 11.5 3.4 6.5 1.5 11.1 3.8 5.3 1.5 9.9 1.9 52 17 35 255 0 0 0 0 12.5 0 12.7 12.5 05/12/2005 04:30:00 6.6 1.4 10.3 2.3 6.5 1.5 10.3 2.3 5.2 1.4 8 1.5 57 18 53 255 0 0 0 0 12.5 0.1 13 12.2 05/12/2005 04:40:00 6.4 1.6 11.1 1.9 6.4 1.6 11.1 2.3 5.1 1.5 10.3 1.5 57 17 52 255 0 0 0 0 12.8 0 12.7 12.7 05/12/2005 04:50:00 6.1 1.2 8.8 2.6 6 1.3 8.8 2.3 4.8 1.1 7.6 1.5 56 17 56 255 0 0 0 0 12.5 0 12.7 12.5 05/12/2005 05:00:00 5.4 1 8.4 2.6 5.4 1 8 3.4 4.5 1.1 8 1.9 61 17 72 255 0 0 0 0 12.5 0 12.7 12.5 05/12/2005 05:10:00 5.9 1.1 8.8 3 5.9 1.1 8.4 3 4.8 1.2 7.6 1.9 54 16 51 255 0 0 0 0 12.7 0 12.7 12.5 05/12/2005 05:20:00 5.1 1.2 8 2.3 5 1.2 8 2.3 4.1 1.2 7.6 1.1 67 15 68 255 0 0 0 0 12.7 0 13 12.5 05/12/2005 05:30:00 4 0.8 6.1 1.9 4 1 6.5 1.5 3.1 1 5.3 0.7 82 17 69 255 0 0 0 0 11.7 0.2 12.5 11.4 05/12/2005 05:40:00 4.1 1 6.8 1.5 4 1 6.8 1.5 3.1 1.1 5.7 0.4 79 16 84 255 0 0 0 0 11.4 0 11.7 11.4 05/12/2005 05:50:00 4.2 1.2 8 1.5 4.2 1.2 8 1.1 3.2 1 6.5 1.1 67 17 51 255 0 0 0 0 11.7 0 11.9 11.4 05/12/2005 06:00:00 3.3 0.9 6.1 1.5 3.2 0.9 6.5 1.5 2.5 1 6.1 0.4 70 17 43 255 0 0 0 0 11.7 0 12.2 11.7 05/12/2005 06:10:00 4.4 1.2 8 1.9 4.3 1.2 8 1.5 3.5 1.2 7.2 1.1 73 18 58 255 0 0 0 0 12.1 0 12.7 11.7 05/12/2005 06:20:00 3.4 1.1 6.1 1.1 3.2 1.1 5.7 1.1 2.6 1.2 5.7 0.4 66 22 74 255 0 0 0 0 12.3 0 12.7 12.2 05/12/2005 06:30:00 4.1 1.5 8.4 0.7 4 1.7 8.4 0.7 3.5 1.3 7.2 0.4 61 27 37 255 0 0 0 0 12.7 0.1 13 12.5 05/12/2005 06:40:00 4.8 1.5 9.9 2.3 4.7 1.5 9.9 1.9 3.8 1.4 9.1 1.5 68 23 68 255 0 0 0 0 12.8 0.2 13.5 12.5 05/12/2005 06:50:00 4.4 1.5 8.8 1.1 4.4 1.5 8.8 1.5 3.6 1.4 7.2 0.4 74 28 86 255 0 0 0 0 13.3 0 13.8 13.3 05/12/2005 07:00:00 4.4 1.6 8 0.4 4.3 1.7 8 0.4 3.6 1.7 7.6 0.4 80 27 84 255 0 0 0 0 13.5 0.1 14.1 13.3 05/12/2005 07:10:00 4.1 1 6.8 0.7 4.1 1 6.5 1.1 3.3 1.1 6.5 0.7 84 21 88 255 0 0 0 0 13.6 0.1 14.1 13.5 05/12/2005 07:20:00 4 1.3 7.2 0.7 3.9 1.3 7.6 0.7 3.1 1.4 6.1 0.4 71 22 77 255 0 0 0 0 14.2 0.4 15.2 13.5 05/12/2005 07:30:00 4.4 1.1 6.8 0.7 4.3 1.2 7.2 0.7 3.8 1.2 7.2 1.1 85 18 77 255 0 0 0 0 14.8 0 15.5 14.6 05/12/2005 07:40:00 3.8 0.9 6.8 1.1 3.8 1 6.8 1.5 3.1 1 6.1 0.4 74 19 79 255 0 0 0 0 14.2 0.2 15.2 13.8 05/12/2005 07:50:00 4 1.1 6.8 1.5 4 1 6.8 1.1 3.3 1.1 6.1 0.7 70 16 71 255 0 0 0 0 13.9 0 14.4 13.5 05/12/2005 08:00:00 3.8 0.9 6.1 1.1 3.7 1 6.1 1.1 3.1 1.1 6.1 0.4 64 18 50 255 0 0 0 0 13.9 0 14.6 13.5 05/12/2005 08:10:00 4.1 1 6.5 1.5 4.1 1 6.5 1.5 3.6 1 5.7 0.7 73 16 74 255 0 0 0 0 14.2 0.1 14.6 14.1 05/12/2005 08:20:00 3.7 1.2 6.5 0.4 3.7 1.2 6.5 1.1 3 1 6.5 0.4 56 18 64 255 0 0 0 0 14.7 0.2 15.5 14.4 05/12/2005 08:30:00 3.7 1 6.5 1.5 3.7 1 6.5 1.5 3 1 6.1 0.7 56 22 79 255 0 0 0 0 15.7 0.3 16.3 15.2 05/12/2005 08:40:00 4 0.8 6.5 2.3 3.9 0.8 6.5 2.3 3.2 0.9 5.3 0.7 48 15 26 255 0 0 0 0 15.9 0 16.6 15.7 05/12/2005 08:50:00 4.2 0.9 7.2 1.9 4.1 1 6.8 1.9 3.4 0.9 6.5 1.5 25 13 10 255 0 0 0 0 16.3 0.2 16.8 16.3 05/12/2005 09:00:00 5.8 1.3 9.9 3 5.6 1.3 9.9 2.6 4.5 1.4 8.4 0.7 22 17 4 255 0 0 0 0 17.4 0.2 18 16.8 05/12/2005 09:10:00 6.9 1.1 9.1 3.8 6.8 1.1 9.1 3 5.6 1.4 9.1 1.5 24 11 30 255 0 0 0 0 17 0.2 17.7 16.8 05/12/2005 09:20:00 7 1 9.9 3.8 7 1.1 9.9 3.8 5.5 1.5 8.8 2.3 17 12 22 255 0 0 0 0 16.8 0 17.1 16.6 05/12/2005 09:30:00 6.9 1 9.9 3.8 6.9 1 9.5 4.6 5.5 1.3 9.1 2.6 19 12 24 255 0 0 0 0 16.4 0.1 16.8 16.3 05/12/2005 09:40:00 7.5 1.3 10.7 3.8 7.5 1.3 10.7 4.2 6 1.6 10.7 1.9 21 12 31 255 0 0 0 0 16.4 0.1 16.8 16.3 05/12/2005 09:50:00 6.9 1.1 10.3 4.6 6.8 1.1 10.3 4.2 5.6 1.3 9.9 2.6 22 13 8 255 0 0 0 0 16.6 0 16.8 16.6 05/12/2005 10:00:00 7.6 1.5 11.5 3.8 7.5 1.5 11.5 3 5.9 1.7 10.7 1.9 17 11 24 255 0 0 0 0 16.8 0 17.1 16.8 05/12/2005 10:10:00 7.1 1.3 10.3 4.2 7 1.3 10.7 3.8 5.7 1.5 9.9 1.9 24 13 37 255 0 0 0 0 16.8 0 17.1 16.8 05/12/2005 10:20:00 7.9 1.1 10.7 4.2 7.8 1.1 10.7 3.8 6.2 1.4 9.1 1.9 19 9 23 255 0 0 0 0 16.9 0 17.1 16.8 05/12/2005 10:30:00 7.5 1.4 10.7 2.6 7.5 1.4 10.7 2.3 5.8 1.5 9.1 1.1 17 11 16 255 0 0 0 0 17 0 17.1 16.8 05/12/2005 10:40:00 7.5 1.2 11.1 4.2 7.4 1.2 11.1 4.2 5.5 1.7 10.7 1.5 17 13 20 255 0 0 0 0 17.2 0 17.4 16.8 05/12/2005 10:50:00 7.8 1 10.3 4.2 7.7 1 10.7 4.6 6.1 1.4 9.5 2.3 16 10 20 255 0 0 0 0 17.2 0 17.4 17.1 05/12/2005 11:00:00 7.9 1.1 11.5 5.7 7.9 1.1 11.5 5.3 6.5 1.4 9.5 2.3 17 9 8 255 0 0 0 0 17.3 0 17.4 17.1 05/12/2005 11:10:00 7.6 1.3 10.7 4.6 7.6 1.4 10.7 4.2 6.3 1.4 9.9 3 25 12 16 255 0 0 0 0 17.2 0 17.4 16.8 05/12/2005 11:20:00 7.1 0.9 9.1 4.2 7 0.9 9.1 3.8 5.4 1.2 8.4 1.5 19 10 19 255 0 0 0 0 17.3 0.1 17.7 17.1 05/12/2005 11:30:00 8.1 1 10.3 4.9 8 1 10.7 4.6 6.7 1.3 9.9 3 22 10 14 255 0 0 0 0 17.5 0 17.7 17.4 05/12/2005 11:40:00 7.2 1.2 10.3 3.8 7.1 1.2 9.9 3.4 5.6 1.6 8.4 1.5 18 10 10 255 0 0 0 0 17.7 0 18 17.4 05/12/2005 11:50:00 4.5 1.1 8 1.9 4.1 1.2 7.6 1.5 3.2 1.2 6.5 0.4 345 21 28 255 0 0 0 0 18 0 18.2 17.7 05/12/2005 12:00:00 2.8 1 5.3 0.4 2.5 1.1 5.7 0.4 1.9 1 4.2 0.4 314 19 328 255 0 0 0 0 17.9 0 18.2 17.7 05/12/2005 12:10:00 4.3 1.3 8 1.9 4 1.5 8.4 0.7 3 1.4 7.6 0.4 333 21 337 255 0 0 0 0 18 0 18.2 17.7 05/12/2005 12:20:00 2.5 0.9 4.9 0.7 2.2 0.9 4.9 0.4 1.9 0.9 5.3 0.4 320 28 329 255 0 0 0 0 18.8 0.4 19.4 18 05/12/2005 12:30:00 3.9 0.9 6.1 1.9 3.6 1 6.1 1.1 2.9 1.1 5.7 0.4 348 27 23 255 0 0 0 0 19.1 0 19.4 18.8 05/12/2005 12:40:00 7.6 1.3 10.7 3 7.5 1.3 9.9 3.4 6.1 1.5 9.1 2.6 20 11 23 255 0 0 0 0 19.9 0.3 20.5 19.4 05/12/2005 12:50:00 6.5 1.6 10.3 2.6 6.5 1.7 10.3 2.3 4.9 1.9 8.8 1.5 16 14 31 255 0 0 0 0 19.2 0 19.7 19.1 05/12/2005 13:00:00 7.4 1.2 9.9 3.8 7.3 1.2 10.3 4.2 6.1 1.5 9.9 1.9 24 13 26 255 0 0 0 0 19.2 0 19.7 19.1 05/12/2005 13:10:00 6.7 1.3 11.8 3.4 6.6 1.3 11.5 3.4 5.3 1.6 10.7 0.7 20 17 19 255 0 0 0 0 19 0 19.4 18.8 05/12/2005 13:20:00 7.4 1.9 11.8 3 7.3 2 11.8 3 5.3 2.1 10.3 1.5 14 12 25 255 0 0 0 0 19 0 19.4 18.8 05/12/2005 13:30:00 8.4 1.2 11.8 4.9 8.3 1.2 11.8 4.6 6.8 1.3 10.3 2.6 16 10 22 255 0 0 0 0 18.7 0.2 19.7 18.5 05/12/2005 13:40:00 8.4 1.4 11.8 4.6 8.4 1.5 11.8 4.2 6.6 1.7 10.7 1.5 16 12 16 255 0 0 0 0 19.5 0.1 20.3 19.4 05/12/2005 13:50:00 8.2 1.5 11.8 4.6 8.1 1.6 11.8 3.8 6.4 1.9 10.7 1.5 20 15 18 255 0 0 0 0 19.6 0.2 20.5 19.4 05/12/2005 14:00:00 7.4 1.4 11.1 3.8 7.4 1.5 11.1 3.8 5.5 1.8 9.9 1.5 13 15 15 255 0 0 0 0 20 0.1 20.5 19.4 05/12/2005 14:10:00 7.1 1.3 10.3 3.8 7 1.3 10.7 3.4 4.9 1.7 10.3 1.5 7 17 15 255 0 0 0 0 19.1 0.2 20 18.5 05/12/2005 14:20:00 6.3 1.4 10.7 3 6.2 1.5 10.7 2.3 4.5 1.6 10.3 1.1 10 17 15 255 0 0 0 0 18.3 0.2 19.1 17.7 05/12/2005 14:30:00 6 1.7 11.8 2.6 5.9 1.7 11.5 2.6 4.6 1.5 9.9 1.9 26 18 25 255 0 0 0 0 17.8 0 18.2 17.4 05/12/2005 14:40:00 7.3 1.4 11.5 3 7.3 1.5 11.1 3 5.5 1.6 11.5 2.3 13 15 16 255 0 0 0 0 17.6 0 18.2 17.4 05/12/2005 14:50:00 9.7 2.1 14.5 4.9 9.7 2.1 14.5 4.9 7.5 2.4 13 2.3 15 12 6 255 0 0 0 0 17.1 0 18 16.8 05/12/2005 15:00:00 7.9 2 12.2 2.3 7.8 2 12.2 1.9 5.8 2.3 11.1 0.4 13 13 358 255 0 0 0 0 17 0 17.1 16.8 05/12/2005 15:10:00 8 1.7 12.2 3 8 1.7 12.2 3.4 6.2 1.9 11.1 1.9 19 14 17 255 0 0 0 0 16.8 0 16.8 16.8 05/12/2005 15:20:00 7.1 1.2 10.3 4.2 7 1.2 10.3 4.2 5.6 1.3 8.8 3 22 14 31 255 0 0 0 0 17.1 0.1 17.1 16.8 05/12/2005 15:30:00 6.8 1.5 11.5 3.4 6.7 1.5 10.7 3.4 5.1 1.7 9.1 1.5 19 16 23 255 0 0 0 0 17.1 0 17.1 16.8 05/12/2005 15:40:00 7.2 1.7 11.1 3 7.1 1.8 11.5 2.3 5.5 1.7 10.3 0.7 9 16 12 255 0 0 0 0 16.9 0 17.1 16.8 05/12/2005 15:50:00 7 1.7 11.5 2.6 6.9 1.7 11.5 1.9 5.3 1.9 10.3 1.5 17 13 40 255 0 0 0 0 16.8 0 16.8 16.8 05/12/2005 16:00:00 7.1 1.6 11.1 1.5 7.1 1.7 11.5 1.1 5.6 1.7 9.9 0.4 14 20 1 255 0 0 0 0 16.6 0 16.8 16.6 05/12/2005 16:10:00 6.7 1.7 11.8 2.6 6.7 1.7 11.5 2.6 5 1.8 10.7 1.5 15 10 31 255 0 0 0 0 16.4 0 16.8 16.3 05/12/2005 16:20:00 7.4 1.7 11.8 4.2 7.3 1.7 12.2 3.8 5.5 1.9 9.9 1.5 16 13 22 255 0 0 0 0 16.4 0 16.8 16.3 05/12/2005 16:30:00 6.6 1.6 11.1 3 6.5 1.7 11.1 3 5.1 1.5 9.9 1.9 21 16 12 255 0 0 0 0 16.1 0 16.6 16 05/12/2005 16:40:00 7 1.5 11.1 2.6 6.9 1.5 11.1 3 5.1 1.7 8.8 1.1 19 13 17 255 0 0 0 0 16 0 16.3 16 05/12/2005 16:50:00 8.2 1.3 11.8 4.6 8.2 1.3 11.5 4.9 6.7 1.5 10.7 3 21 11 21 255 0 0 0 0 15.8 0 16 15.7 05/12/2005 17:00:00 7.1 1.3 10.7 3.4 7.1 1.3 11.1 3.4 5.8 1.5 10.3 2.3 20 12 24 255 0 0 0 0 15.7 0 16 15.7 05/12/2005 17:10:00 7.6 1.4 11.1 3.8 7.5 1.5 11.1 3.8 6.3 1.5 10.7 3 17 9 24 255 0 0 0 0 15.6 0 16 15.5 05/12/2005 17:20:00 7.4 1.5 11.1 3.8 7.3 1.6 11.1 3.8 6.1 1.7 11.1 2.3 20 12 23 255 0 0 0 0 15.4 0 15.7 15.2 05/12/2005 17:30:00 7.2 1.2 10.3 3 7.1 1.2 10.3 3 5.4 1.5 9.1 1.9 22 15 32 255 0 0 0 0 15.2 0 15.7 15.2 05/12/2005 17:40:00 6.9 1.3 10.7 4.2 6.8 1.3 10.3 4.2 5.3 1.5 9.9 2.3 16 11 6 255 0 0 0 0 15 0 15.5 14.9 05/12/2005 17:50:00 6.1 1.3 9.5 2.6 6 1.3 9.1 2.6 4.7 1.4 8.8 1.5 18 13 11 255 0 0 0 0 15 0 15.5 14.9 05/12/2005 18:00:00 6.1 1.5 11.1 3.4 6 1.5 11.1 2.6 4.7 1.7 11.5 1.5 25 15 26 255 0 0 0 0 14.8 0 15.2 14.6 05/12/2005 18:10:00 6.9 1.4 10.3 3.4 6.9 1.4 10.3 3 5.3 1.7 9.5 1.1 20 15 15 255 0 0 0 0 14.6 0 15.2 14.4 05/12/2005 18:20:00 6.9 1.2 9.9 3.8 6.8 1.2 9.9 3.8 5.4 1.3 8.8 1.5 24 15 32 255 0 0 0 0 14.4 0 15.2 14.4 05/12/2005 18:30:00 6.3 1.3 10.3 3.4 6.2 1.4 9.9 3 4.9 1.5 8.8 1.5 21 13 14 255 0 0 0 0 14.3 0 14.6 14.4 05/12/2005 18:40:00 7 1.1 9.9 4.2 7 1 9.9 4.2 5.6 1.3 9.5 1.9 22 13 24 255 0 0 0 0 14.2 0 14.6 14.1 05/12/2005 18:50:00 5.7 1.2 8.8 2.6 5.6 1.2 8.8 2.6 4.2 1.4 8.8 1.1 21 14 30 255 0 0 0 0 14.2 0.1 14.6 14.1 05/12/2005 19:00:00 5.7 0.9 8.4 3.4 5.6 0.9 8 3.4 4.4 1.3 8 1.1 20 11 14 255 0 0 0 0 14.2 0.2 14.6 13.8 05/12/2005 19:10:00 5 1 7.6 2.3 4.9 1 7.2 1.9 3.4 1.3 6.8 0.4 12 13 21 255 0 0 0 0 14 0.1 14.6 13.8 05/12/2005 19:20:00 4.5 0.8 6.8 1.9 4.4 0.8 6.8 1.5 3.4 0.9 5.7 1.1 20 13 14 255 0 0 0 0 13.9 0 14.4 13.8 05/12/2005 19:30:00 4.7 0.7 6.1 2.3 4.6 0.7 6.5 2.6 3.2 1.1 5.3 0.4 19 11 15 255 0 0 0 0 13.8 0 14.4 13.5 05/12/2005 19:40:00 5 1.1 8 2.3 4.9 1.2 7.6 2.3 3.9 1.2 6.5 1.5 23 11 15 255 0 0 0 0 13.7 0 14.4 13.5 05/12/2005 19:50:00 5.1 0.9 8 2.6 5.1 0.9 8 3 4 1.1 6.8 1.9 28 13 30 255 0 0 0 0 13.6 0.1 13.8 13.3 05/12/2005 20:00:00 5.4 0.8 7.2 2.6 5.3 0.8 7.2 2.6 4.1 1.2 6.5 1.5 20 11 11 255 0 0 0 0 13.4 0 13.8 13.3 05/12/2005 20:10:00 5.3 1 7.6 2.6 5.2 1 7.2 2.3 3.9 1.5 7.2 0.4 14 12 11 255 0 0 0 0 13.3 0 13.8 13 05/12/2005 20:20:00 5.2 1 7.6 3 5.2 1 7.6 2.6 3.5 1.2 7.2 0.7 10 10 14 255 0 0 0 0 13.1 0 13.3 12.7 05/12/2005 20:30:00 5.8 0.9 8.4 3.4 5.7 0.9 8.4 3.4 4.1 1.2 7.2 0.4 14 11 24 255 0 0 0 0 12.9 0 13.3 12.7 05/12/2005 20:40:00 6.2 1 8.8 3 6.1 1 8.8 3.4 4.5 1.2 8.4 1.5 14 9 16 255 0 0 0 0 12.8 0 13.3 12.7 05/12/2005 20:50:00 4.9 1 7.2 2.6 4.8 1 7.6 2.3 3.6 1.2 6.8 1.1 12 11 20 255 0 0 0 0 12.7 0 13.3 12.5 05/12/2005 21:00:00 4.6 0.8 7.6 2.6 4.6 0.8 7.2 3 3 1.1 5.7 0.4 11 13 34 255 0 0 0 0 12.4 0 13 12.2 05/12/2005 21:10:00 4.8 1.2 7.6 1.5 4.8 1.2 7.6 1.5 3.3 1.2 6.5 0.4 9 13 26 255 0 0 0 0 12.2 0 12.5 11.9 05/12/2005 21:20:00 5.3 1.2 9.1 2.3 5.2 1.2 9.1 2.3 3.8 1.5 7.6 0.4 16 16 10 255 0 0 0 0 12 0 12.2 11.9 05/12/2005 21:30:00 4.6 1.2 8 1.9 4.5 1.2 8 1.9 3 1.3 6.5 0.4 13 14 13 255 0 0 0 0 12 0 12.2 11.9 05/12/2005 21:40:00 3.5 1.1 6.5 1.1 3.4 1.2 6.8 0.7 2 1.1 5.3 0.4 10 19 321 255 0 0 0 0 11.6 0 11.9 11.4 05/12/2005 21:50:00 4.3 0.9 6.8 2.6 4.2 1 6.8 2.3 2.6 1.1 5.3 0.4 8 17 17 255 0 0 0 0 11.4 0 11.4 11.4 05/12/2005 22:00:00 4.1 1.1 7.2 1.1 4 1.1 6.8 1.1 2.6 1.2 5.3 0.4 4 15 349 255 0 0 0 0 11.3 0 11.4 11.4 05/12/2005 22:10:00 4.2 1.1 6.8 0.7 4.1 1.2 6.8 0.4 2.9 1.3 7.2 0.4 8 15 22 255 0 0 0 0 11.3 0 11.4 11.1 05/12/2005 22:20:00 4 1.1 6.8 1.1 4 1.2 6.8 0.7 2.9 1.3 5.7 0.4 17 13 10 255 0 0 0 0 11.3 0 11.4 11.1 05/12/2005 22:30:00 3.8 0.6 5.7 2.3 3.7 0.6 6.1 2.3 2.7 1 4.9 0.7 18 10 18 255 0 0 0 0 11.2 0 11.4 11.1 05/12/2005 22:40:00 2.9 0.5 4.6 1.5 2.8 0.6 4.2 1.5 1.9 0.6 3.8 0.4 22 9 26 255 0 0 0 0 11 0 11.1 10.9 05/12/2005 22:50:00 2.7 0.5 4.6 1.5 2.5 0.6 4.2 1.1 1.6 0.8 3.4 0.4 15 11 1 255 0 0 0 0 10.7 0.1 11.1 10.3 05/12/2005 23:00:00 3.2 0.4 4.2 2.3 3 0.4 4.2 1.9 2.1 0.6 3.4 0.4 17 7 19 255 0 0 0 0 10.2 0 10.6 10.1 05/12/2005 23:10:00 3 0.4 4.2 1.9 2.9 0.5 4.2 1.9 1.9 0.8 3.8 0.4 14 8 17 255 0 0 0 0 9.8 0.1 10.1 9.6 05/12/2005 23:20:00 3.6 0.9 6.1 1.5 3.5 0.9 6.1 1.5 2.3 1 4.9 0.4 15 9 27 255 0 0 0 0 9.6 0 9.8 9.6 05/12/2005 23:30:00 4 0.7 6.1 2.3 4 0.7 6.1 2.3 2.7 0.8 4.9 0.4 15 9 18 255 0 0 0 0 10 0 10.3 9.8 05/12/2005 23:40:00 3.9 0.7 6.1 1.9 3.8 0.7 6.1 2.3 3 0.8 4.9 1.1 24 11 15 255 0 0 0 0 10.5 0.1 10.9 10.3 05/12/2005 23:50:00 3.8 0.6 5.3 2.3 3.7 0.6 4.9 2.3 2.9 0.7 4.6 1.1 37 13 36 255 0 0 0 0 11.1 0 11.4 10.9 05/13/2005 00:00:00 4.4 1.1 7.2 1.5 4.3 1.2 7.2 1.1 3.4 1.2 6.5 0.4 44 13 49 255 0 0 0 0 11.1 0 11.1 11.1 05/13/2005 00:10:00 3.4 0.8 5.7 1.9 3.3 0.8 5.7 1.5 2.5 0.9 5.7 0.4 46 9 46 255 0 0 0 0 11 0 11.1 10.6 05/13/2005 00:20:00 2.7 1.1 6.1 0.7 2.5 1.2 5.7 0.4 1.8 1.1 4.9 0.4 29 20 12 255 0 0 0 0 10.5 0 10.9 10.3 05/13/2005 00:30:00 2.3 1 5.3 0.4 2 1.1 5.7 0.4 1.5 1 3.8 0.4 61 27 88 255 0 0 0 0 10.2 0 10.3 9.8 05/13/2005 00:40:00 2.2 0.6 3.8 0.4 1.9 0.7 3.8 0.4 1.3 0.7 3 0.4 80 22 71 255 0 0 0 0 10.2 0.1 10.3 9.8 05/13/2005 00:50:00 3.4 0.8 5.7 1.5 3.2 0.8 5.7 1.5 2.5 0.7 4.6 1.1 52 22 39 255 0 0 0 0 10 0 10.3 9.8 05/13/2005 01:00:00 2.8 0.6 4.6 0.7 2.7 0.8 4.9 0.4 2 0.8 3.8 0.4 88 21 90 255 0 0 0 0 9.9 0.1 10.3 9.6 05/13/2005 01:10:00 2.7 0.8 4.6 0.7 2.6 0.8 4.2 0.4 2.1 0.8 4.2 0.4 70 16 70 255 0 0 0 0 9.7 0 9.8 9.6 05/13/2005 01:20:00 3.2 0.6 4.9 1.5 3.1 0.7 5.3 1.5 2.5 0.7 4.2 0.7 66 13 69 255 0 0 0 0 9.2 0.1 9.6 9 05/13/2005 01:30:00 3.3 0.8 5.3 1.5 3.1 0.8 5.3 1.5 2.1 0.8 4.2 0.4 73 12 60 255 0 0 0 0 9 0 9.3 8.8 05/13/2005 01:40:00 3.5 0.7 5.3 1.9 3.4 0.7 5.3 1.9 2.7 0.7 4.9 0.7 77 13 65 255 0 0 0 0 8.5 0.1 9 8.5 05/13/2005 01:50:00 4.4 0.9 7.2 2.3 4.4 1 6.8 2.3 3.4 1 6.1 1.1 61 15 56 255 0 0 0 0 8.9 0.2 9.3 8.5 05/13/2005 02:00:00 4.4 0.7 6.5 1.9 4.4 0.8 6.5 2.3 3.5 0.8 5.3 0.7 62 13 63 255 0 0 0 0 9 0 9.3 8.8 05/13/2005 02:10:00 3.6 0.8 5.3 1.5 3.5 0.9 5.7 1.5 2.5 0.8 4.6 0.4 56 14 59 255 0 0 0 0 8.7 0.1 9 8.5 05/13/2005 02:20:00 2.5 0.5 4.2 1.1 2.3 0.6 4.2 0.7 1.6 0.7 3.4 0.4 94 18 102 255 0 0 0 0 8.1 0.2 8.5 7.8 05/13/2005 02:30:00 2.9 0.5 4.6 1.5 2.7 0.6 4.2 1.1 1.9 0.6 3.4 0.4 101 8 106 255 0 0 0 0 7.8 0 8 7.5 05/13/2005 02:40:00 2.8 0.6 4.6 1.1 2.6 0.6 4.9 1.1 1.7 0.6 3.8 0.4 98 15 68 255 0 0 0 0 6.8 0.4 7.5 6.2 05/13/2005 02:50:00 3.6 0.7 5.3 1.9 3.5 0.7 5.3 1.9 2.6 0.6 4.2 0.7 84 12 74 255 0 0 0 0 6.7 0.3 7.3 6.2 05/13/2005 03:00:00 4.2 0.6 5.7 2.3 4.1 0.7 5.7 2.3 3 0.8 4.9 1.1 98 13 78 255 0 0 0 0 7.8 0.2 8 7.3 05/13/2005 03:10:00 4.2 1 6.5 1.9 4.1 1 6.5 1.9 2.9 1 5.3 0.7 111 16 102 255 0 0 0 0 8.2 0 8.5 8 05/13/2005 03:20:00 4.5 0.7 6.1 2.3 4.4 0.8 6.1 1.9 3.3 0.9 5.3 0.7 103 13 101 255 0 0 0 0 7.9 0 8 7.8 05/13/2005 03:30:00 4.3 0.6 6.1 2.6 4.2 0.6 5.7 3 3.1 0.9 5.7 1.1 97 12 102 255 0 0 0 0 8.1 0 8.5 8 05/13/2005 03:40:00 4.5 0.7 6.1 2.6 4.4 0.7 6.1 2.3 3.2 0.8 5.3 1.1 94 10 92 255 0 0 0 0 8.5 0 8.8 8.5 05/13/2005 03:50:00 3.9 0.9 6.5 1.9 3.8 0.9 6.1 1.1 2.9 0.8 4.9 0.7 87 15 77 255 0 0 0 0 9 0.1 9.3 8.8 05/13/2005 04:00:00 3.3 0.6 5.3 1.9 3.2 0.6 4.9 1.9 2.4 0.6 4.2 0.7 92 12 92 255 0 0 0 0 9.2 0 9.3 9 05/13/2005 04:10:00 3.2 0.7 5.7 1.5 3.1 0.6 5.3 1.5 2.1 0.7 4.2 0.4 94 13 100 255 0 0 0 0 8.8 0 9 8.5 05/13/2005 04:20:00 2.7 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.7 0.7 3.8 0.4 106 13 119 255 0 0 0 0 8.5 0 8.8 8.3 05/13/2005 04:30:00 3.3 0.6 4.6 1.5 3.1 0.6 4.9 1.1 2.3 0.7 3.8 0.7 101 14 99 255 0 0 0 0 8.4 0 8.5 8.3 05/13/2005 04:40:00 3.3 0.6 4.6 1.1 3.2 0.6 4.6 1.1 2.2 0.6 3.8 0.7 90 11 92 255 0 0 0 0 8.3 0 8.5 8.3 05/13/2005 04:50:00 3.6 0.7 4.9 1.1 3.5 0.7 4.9 0.7 2.4 0.7 4.2 0.4 82 13 92 255 0 0 0 0 8.4 0 8.5 8.3 05/13/2005 05:00:00 4 1 6.8 1.9 4 1 7.2 1.9 3.1 1 5.7 0.4 68 13 74 255 0 0 0 0 8.9 0.2 9.3 8.5 05/13/2005 05:10:00 3.1 0.7 5.3 1.5 2.9 0.8 5.3 0.7 2.2 0.7 3.8 0.4 77 17 55 255 0 0 0 0 9.4 0 9.6 9.3 05/13/2005 05:20:00 3.2 0.8 5.3 1.5 3.1 0.9 5.7 0.4 2.3 0.9 4.9 0.4 81 15 62 255 0 0 0 0 9.2 0 9.6 9 05/13/2005 05:30:00 3.4 0.9 6.1 1.5 3.3 0.9 6.1 1.5 2.6 1 5.3 0.4 70 18 40 255 0 0 0 0 9.4 0 9.6 9.3 05/13/2005 05:40:00 2.9 0.7 4.9 1.5 2.8 0.8 4.9 0.7 2.1 0.9 4.9 0.4 64 22 83 255 0 0 0 0 9.6 0.1 9.8 9.6 05/13/2005 05:50:00 2.2 0.9 4.2 0.4 2.1 1 4.2 0.4 1.4 1 3.4 0.4 107 28 116 255 0 0 0 0 9.8 0 9.8 9.6 05/13/2005 06:00:00 2.6 0.7 4.6 0.7 2.4 0.8 4.2 0.4 1.7 0.8 3.8 0.4 100 22 100 255 0 0 0 0 10 0 10.1 9.8 05/13/2005 06:10:00 1.9 0.8 3.4 0.4 1.7 0.9 3.4 0.4 1.2 0.7 3 0.4 84 27 95 255 0 0 0 0 10.2 0 10.3 10.1 05/13/2005 06:20:00 1.8 1 5.3 0.4 1.6 1 4.9 0.4 1.3 0.9 4.9 0.4 70 21 44 255 0 0 0 0 10.2 0 10.6 10.1 05/13/2005 06:30:00 1.7 0.6 3.4 0.7 1.4 0.8 3.4 0.4 1 0.5 2.6 0.4 81 27 49 255 0 0 0 0 10.5 0 10.6 10.3 05/13/2005 06:40:00 1.9 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1.1 0.7 2.6 0.4 55 20 40 255 0 0 0 0 10.6 0 10.6 10.6 05/13/2005 06:50:00 3.2 1.1 8 1.5 3.1 1.2 8 1.1 2.1 1.1 6.5 0.4 81 17 91 255 0 0 0 0 10.7 0 10.9 10.6 05/13/2005 07:00:00 4.2 1 7.6 1.9 4.1 1 8 1.9 3.4 1 6.1 0.7 78 16 45 255 0 0 0 0 10.8 0 11.1 10.9 05/13/2005 07:10:00 5.1 1.3 8.4 2.3 5 1.3 8.8 2.3 4.2 1.3 7.6 1.5 73 16 71 255 0 0 0 0 11.1 0 11.4 10.9 05/13/2005 07:20:00 5.4 1.2 8.4 3 5.4 1.3 8.4 2.3 4.4 1.3 7.6 1.1 72 16 68 255 0 0 0 0 11.5 0.1 11.9 11.1 05/13/2005 07:30:00 5.1 1.1 7.6 2.3 5.1 1.1 8 2.3 4.1 1.3 7.2 1.1 58 19 35 255 0 0 0 0 12.1 0 12.5 11.7 05/13/2005 07:40:00 5.5 1.5 9.1 2.3 5.4 1.5 9.5 2.6 4.6 1.6 9.1 1.1 62 19 55 255 0 0 0 0 12.3 0 12.5 12.2 05/13/2005 07:50:00 6.2 1.5 11.1 3 6.2 1.5 11.5 3 5.1 1.5 8.4 1.9 63 17 61 255 0 0 0 0 12.4 0 12.5 12.2 05/13/2005 08:00:00 6.1 1.2 10.7 2.6 6 1.2 10.3 2.6 5.1 1.3 9.5 1.9 47 14 44 255 0 0 0 0 12.3 0 12.5 12.2 05/13/2005 08:10:00 6 1.3 9.1 3 5.9 1.4 9.5 2.3 4.9 1.4 8.4 0.7 56 17 52 255 0 0 0 0 11.8 0.1 12.2 11.7 05/13/2005 08:20:00 5.7 1 8.4 3.4 5.6 1 8.4 2.6 4.8 1 6.8 2.6 68 15 69 255 0 0 0 0 11.7 0 11.7 11.7 05/13/2005 08:30:00 4.4 1 7.6 2.3 4.3 1.1 8 1.5 3.4 1.1 6.5 0.4 65 18 67 255 0 0 0 0 11.7 0 11.9 11.7 05/13/2005 08:40:00 4.6 1 8.4 2.6 4.6 1 8.4 2.3 3.7 1.1 8.4 0.7 65 16 48 255 0 0 0 0 12 0 12.2 11.9 05/13/2005 08:50:00 5.8 1.3 9.5 2.6 5.8 1.3 9.5 2.6 4.6 1.5 8 0.7 56 15 56 255 0 0 0 0 12.2 0 12.2 12.2 05/13/2005 09:00:00 4.8 1.5 9.5 1.5 4.8 1.5 9.9 1.9 4 1.5 8.8 1.5 60 15 57 255 0 0 0 0 12.3 0 12.7 12.2 05/13/2005 09:10:00 4 0.8 6.1 2.3 3.9 0.9 6.1 1.5 3.1 1.1 5.7 0.7 63 17 70 255 0 0 0 0 12.3 0 12.7 12.2 05/13/2005 09:20:00 4.9 1.1 7.6 1.1 4.9 1.2 8 0.7 4.2 1.2 8 0.4 61 17 55 255 0 0 0 0 12.5 0 13 12.2 05/13/2005 09:30:00 3.2 0.8 5.3 0.4 3.1 0.9 5.7 0.4 2.4 0.9 4.9 0.4 77 18 48 255 0 0 0 0 12.8 0 13.3 12.7 05/13/2005 09:40:00 3 0.7 4.6 0.4 2.9 0.7 4.2 0.7 2.3 0.8 3.8 0.4 77 17 58 255 0 0 0 0 12.8 0 13.3 12.7 05/13/2005 09:50:00 3.9 1.1 7.6 1.9 3.9 1.1 7.2 1.5 3 1 6.5 0.4 76 21 63 255 0 0 0 0 12.9 0.1 13.5 12.7 05/13/2005 10:00:00 3.4 0.8 5.7 1.1 3.3 0.9 5.3 1.1 2.5 0.8 4.9 0.4 78 19 63 255 0 0 0 0 13.3 0 13.8 13 05/13/2005 10:10:00 3.3 0.9 6.1 1.1 3.2 0.9 6.1 0.7 2.2 0.9 4.6 0.4 87 17 85 255 0 0 0 0 13.4 0 13.8 13.3 05/13/2005 10:20:00 2.9 0.9 4.9 0.4 2.8 0.9 4.9 0.4 2.1 1 4.2 0.4 82 17 80 255 0 0 0 0 13.5 0.1 13.8 13.3 05/13/2005 10:30:00 3.3 1.1 6.1 0.4 3.3 1.1 6.5 0.4 2.4 1.1 5.3 0.4 74 19 62 255 0 0 0 0 13.7 0 14.4 13.5 05/13/2005 10:40:00 4.3 1 6.5 1.9 4.2 1 6.8 1.5 3.4 1 6.1 1.1 57 13 50 255 0 0 0 0 14 0 14.6 13.8 05/13/2005 10:50:00 3.7 0.9 6.1 1.9 3.7 1 6.1 1.5 2.8 1 5.7 0.4 56 17 53 255 0 0 0 0 14.3 0 14.9 14.1 05/13/2005 11:00:00 4 0.9 6.5 1.5 4 1 6.8 1.9 3 1 5.7 1.1 57 15 54 255 0 0 0 0 14.5 0 14.9 14.4 05/13/2005 11:10:00 3.5 1 6.1 1.1 3.4 1.1 6.1 0.4 2.7 1 5.7 0.4 51 17 32 255 0 0 0 0 14.7 0 15.2 14.6 05/13/2005 11:20:00 2.8 0.8 4.9 0.7 2.7 0.9 4.6 0.4 2.1 1 4.6 0.4 70 18 48 255 0 0 0 0 15 0 15.5 14.9 05/13/2005 11:30:00 2.8 0.5 3.8 1.1 2.6 0.6 4.2 0.7 2.1 0.6 3.8 0.4 63 18 76 255 0 0 0 0 15.2 0 15.7 15.2 05/13/2005 11:40:00 2.4 0.7 4.2 0.4 2.2 0.8 3.8 0.4 1.6 0.8 3.4 0.4 50 22 21 255 0 0 0 0 15.9 0.2 16.6 15.5 05/13/2005 11:50:00 3.7 1 5.7 1.1 3.6 1 5.3 0.7 3.1 1.1 5.7 0.7 36 15 26 255 0 0 0 0 16.6 0.1 17.1 16.3 05/13/2005 12:00:00 3.2 0.8 4.9 1.1 3.1 0.9 4.9 0.7 2.5 1 4.9 0.4 52 14 50 255 0 0 0 0 16.9 0 17.4 16.8 05/13/2005 12:10:00 4.1 1 6.8 1.5 4 1.1 6.8 1.1 3.4 1.1 6.5 0.7 32 17 20 255 0 0 0 0 17.3 0.1 17.7 17.1 05/13/2005 12:20:00 5 1 8 2.3 5 1 8 1.9 3.8 1 7.6 1.5 27 17 19 255 0 0 0 0 17.6 0 18.2 17.1 05/13/2005 12:30:00 5.5 1.1 8.8 3 5.4 1.1 8.8 2.6 4.6 1.2 8.8 2.3 35 15 25 255 0 0 0 0 18 0.1 18.2 17.7 05/13/2005 12:40:00 6.1 1.2 8.8 3.4 6 1.2 8.8 3 5 1.2 8 2.6 35 15 24 255 0 0 0 0 18.8 0.2 19.4 18.2 05/13/2005 12:50:00 5.3 1.4 8 1.9 5.3 1.4 8 1.9 4.3 1.6 7.6 0.7 25 15 22 255 0 0 0 0 19.2 0 19.4 18.8 05/13/2005 13:00:00 5.5 1.2 8 2.3 5.4 1.2 8 2.3 4.5 1.2 7.6 1.9 27 15 32 255 0 0 0 0 19.3 0 19.7 19.1 05/13/2005 13:10:00 5.9 1.5 9.9 2.3 5.8 1.5 10.3 1.9 4.5 1.5 8.4 1.1 27 19 16 255 0 0 0 0 19.8 0.3 20.5 19.4 05/13/2005 13:20:00 7.5 1.2 11.1 4.2 7.5 1.3 10.7 3.4 5.7 1.7 11.1 1.1 16 13 28 255 0 0 0 0 20 0 20.5 19.7 05/13/2005 13:30:00 5.9 1.2 9.1 3.4 5.8 1.2 9.1 3 4.8 1.3 8.4 1.9 22 13 17 255 0 0 0 0 20.3 0.1 21.1 20 05/13/2005 13:40:00 5.9 1.1 8.8 3 5.8 1.1 8.8 3 4.7 1.4 8 1.9 26 14 25 255 0 0 0 0 21 0.3 21.7 20.5 05/13/2005 13:50:00 5.2 1.6 8 1.5 5.1 1.6 8 1.1 4.3 1.6 7.6 0.7 36 18 14 255 0 0 0 0 20.9 0.2 21.7 20.5 05/13/2005 14:00:00 5 1.1 7.2 2.3 4.8 1.1 7.6 1.9 4 1.3 7.6 0.4 29 21 21 255 0 0 0 0 21.6 0.3 22.3 20.8 05/13/2005 14:10:00 6.2 1.1 8.8 3 6.1 1.1 8.4 3 5.2 1.3 7.6 2.3 21 13 34 255 0 0 0 0 21.9 0.2 22.3 21.7 05/13/2005 14:20:00 5.3 1.1 8 2.6 5.2 1 8 2.6 4.3 1.2 7.2 1.5 27 13 24 255 0 0 0 0 21.9 0 22.6 21.7 05/13/2005 14:30:00 4.7 1.3 7.6 1.5 4.6 1.3 7.6 1.1 3.5 1.3 6.8 0.4 14 15 14 255 0 0 0 0 22.1 0.1 23.2 22 05/13/2005 14:40:00 5 1.2 8.4 1.9 4.9 1.2 8.4 1.5 3.7 1.4 7.2 1.1 11 19 350 255 0 0 0 0 22.4 0 22.9 22.3 05/13/2005 14:50:00 5 1.5 9.1 1.9 4.9 1.6 8.8 1.5 3.6 1.7 8.4 0.4 10 17 14 255 0 0 0 0 23 0.2 23.5 22.6 05/13/2005 15:00:00 5.3 1.3 9.1 2.6 5.2 1.3 8.8 2.3 3.7 1.3 7.2 0.7 8 19 8 255 0 0 0 0 22.2 0.5 23.5 21.4 05/13/2005 15:10:00 6 1.2 9.1 3 5.9 1.3 9.1 2.6 4.9 1.3 7.6 1.9 16 17 27 255 0 0 0 0 21.4 0 21.7 21.1 05/13/2005 15:20:00 6.5 1.3 9.5 3.4 6.5 1.3 9.5 3.4 4.7 1.5 9.1 1.5 8 17 29 255 0 0 0 0 21.5 0 21.7 21.1 05/13/2005 15:30:00 6.7 1.3 10.3 3 6.7 1.4 9.9 2.6 5.4 1.5 9.9 1.1 23 18 49 255 0 0 0 0 21.2 0.2 21.7 20.8 05/13/2005 15:40:00 6.6 1.5 9.5 2.6 6.5 1.6 9.5 3 5.4 1.8 8.8 1.5 28 21 23 255 0 0 0 0 20.2 0.2 20.8 20 05/13/2005 15:50:00 6.3 1.4 10.7 3.4 6.2 1.4 11.1 3.4 5 1.5 8.8 2.3 33 19 9 255 0 0 0 0 19.5 0.1 20.3 19.4 05/13/2005 16:00:00 6.1 1.1 9.1 3.4 6 1.2 9.1 3.4 4.9 1.5 8.8 0.4 23 15 21 255 0 0 0 0 19.4 0 19.7 19.1 05/13/2005 16:10:00 5.8 1.1 8.8 3.4 5.8 1.1 9.1 3.4 4.9 1.1 8 2.6 33 15 46 255 0 0 0 0 19.1 0.1 19.4 18.8 05/13/2005 16:20:00 4.8 1.2 8 1.5 4.6 1.3 8 1.1 4 1.2 7.2 1.1 40 17 40 255 0 0 0 0 19 0 19.4 18.8 05/13/2005 16:30:00 6.8 2.3 11.8 3 6.7 2.3 11.8 2.6 5.5 2.2 11.1 1.1 27 15 17 255 0 0 0 0 18.7 0 19.1 18.5 05/13/2005 16:40:00 9.4 1.7 13.3 5.3 9.4 1.7 13 4.9 7.5 1.7 12.6 3.4 17 13 19 255 0 0 0 0 18.2 0.1 19.1 18 05/13/2005 16:50:00 8.7 1.6 12.6 3.4 8.6 1.7 12.6 3.8 7 1.7 10.7 3.4 24 12 32 255 0 0 0 0 18.3 0 18.8 18.2 05/13/2005 17:00:00 8.3 2.2 14.1 3 8.1 2.2 13.7 2.6 6.5 2.2 12.6 0.4 18 17 29 255 0 0 0 0 18.1 0.1 18.5 17.7 05/13/2005 17:10:00 4.3 1.5 8.4 0.7 4 1.5 8.8 0.7 3.2 1.5 6.8 0.4 323 29 15 255 0 0 0 0 18.3 0.2 18.5 17.7 05/13/2005 17:20:00 4 1.3 7.2 0.7 3.7 1.4 7.2 0.4 3.1 1.4 7.2 0.4 324 29 314 255 0 0 0 0 17.6 0.2 18.5 17.1 05/13/2005 17:30:00 5.1 1.7 9.5 1.9 4.8 1.9 9.9 1.5 3.5 1.8 7.6 0.4 359 18 10 255 0 0 0 0 17.6 0 17.7 17.4 05/13/2005 17:40:00 5.4 2 10.3 1.9 5.2 2.1 9.9 0.7 3.8 2 9.5 0.4 6 22 14 255 0 0 0 0 17.6 0 17.7 17.4 05/13/2005 17:50:00 6.2 1.6 10.7 2.3 6 1.7 10.7 1.5 4.6 1.7 9.9 0.7 0 22 13 255 0 0 0 0 17.1 0.1 17.7 16.8 05/13/2005 18:00:00 4.9 1.9 10.7 0.7 4.7 2 10.7 0.4 3.8 1.9 9.9 0.4 359 26 5 255 0 0 0 0 16.6 0.1 16.8 16.3 05/13/2005 18:10:00 3.7 1.2 6.8 0.4 3.4 1.3 7.2 0.4 2.6 1.3 7.2 0.4 7 30 14 255 0 0 0 0 16.4 0 16.6 16.3 05/13/2005 18:20:00 3.2 1.3 6.5 0.4 2.9 1.3 6.5 0.4 2.2 1.2 5.3 0.4 2 32 328 255 0 0 0 0 16.1 0 16.6 15.7 05/13/2005 18:30:00 3.2 1.5 7.2 0.4 3.1 1.5 7.2 0.4 2.3 1.5 7.2 0.4 24 17 19 255 0 0 0 0 15.9 0 16 15.7 05/13/2005 18:40:00 3.6 1.3 6.8 1.5 3.5 1.4 6.5 0.7 2.6 1.1 5.7 0.4 26 18 28 255 0 0 0 0 15.8 0 16 15.7 05/13/2005 18:50:00 4.2 1 7.2 1.9 4.1 1 7.6 1.5 3 1.3 7.2 0.4 19 14 44 255 0 0 0 0 15.6 0 16 15.5 05/13/2005 19:00:00 4.8 1.4 9.1 1.9 4.7 1.4 9.1 1.9 3.2 1.3 7.6 0.7 13 15 4 255 0 0 0 0 15.2 0.1 15.7 15.2 05/13/2005 19:10:00 3.6 1.4 6.5 0.4 3.5 1.5 6.5 0.4 2.5 1 4.9 0.4 21 22 2 255 0 0 0 0 14.8 0.1 15.5 14.6 05/13/2005 19:20:00 3.2 1.2 6.1 0.4 3 1.3 6.5 0.4 2.4 1.2 5.3 0.4 45 23 46 255 0 0 0 0 14.6 0 14.9 14.6 05/13/2005 19:30:00 4 1.3 7.6 1.5 3.9 1.3 8.4 1.1 3.3 1.3 6.8 0.4 39 20 32 255 0 0 0 0 14.6 0 14.9 14.4 05/13/2005 19:40:00 2 1 4.6 0.4 1.7 1 4.2 0.4 1.5 1 4.6 0.4 305 28 314 255 0 0 0 0 14.4 0.2 14.9 14.1 05/13/2005 19:50:00 2.3 1.6 6.1 0.4 2.1 1.7 6.1 0.4 1.8 1.2 5.3 0.4 304 82 13 255 0 0 0 0 14.1 0.1 14.6 13.8 05/13/2005 20:00:00 1.7 1.1 5.7 0.4 1.4 1.1 5.7 0.4 1.2 0.9 3.8 0.4 22 29 39 255 0 0 0 0 13.8 0.2 14.4 13.3 05/13/2005 20:10:00 0.7 0.9 3.8 0.4 0.7 0.8 3.8 0.4 0.7 0.8 3.4 0.4 296 82 99 255 0 0 0 0 13.3 0.2 13.8 13 05/13/2005 20:20:00 1.2 1 4.2 0.4 1 1 3.8 0.4 0.8 0.7 3.8 0.4 62 82 11 255 0 0 0 0 12.7 0 13.3 12.5 05/13/2005 20:30:00 1.2 0.8 3.4 0.4 1 0.8 3.4 0.4 0.9 0.7 3 0.4 115 53 343 255 0 0 0 0 12.8 0.1 13.3 12.5 05/13/2005 20:40:00 2.2 1.1 5.3 0.4 2 1.1 5.3 0.4 1.5 1 4.9 0.4 287 47 8 255 0 0 0 0 12.4 0.1 13 12.2 05/13/2005 20:50:00 4.3 1.7 7.2 0.7 4.1 1.8 7.2 0.4 3.2 1.7 6.8 0.4 13 32 41 255 0 0 0 0 12.3 0.2 13 11.9 05/13/2005 21:00:00 4 1 6.5 1.5 3.9 1 6.1 1.9 3.1 1 6.1 1.1 42 17 37 255 0 0 0 0 12.7 0 13 12.7 05/13/2005 21:10:00 3.1 0.8 5.7 1.1 2.9 0.8 4.9 1.1 2.3 0.8 4.2 0.4 44 16 39 255 0 0 0 0 12.7 0 13 12.5 05/13/2005 21:20:00 3.8 0.8 6.5 1.1 3.6 0.8 6.5 1.1 2.9 0.8 5.3 0.4 39 14 44 255 0 0 0 0 12.7 0 13.3 12.5 05/13/2005 21:30:00 3.1 0.7 5.7 1.5 3 0.8 5.7 1.1 1.9 1 4.9 0.4 15 11 22 255 0 0 0 0 12.7 0.1 12.7 12.2 05/13/2005 21:40:00 2.5 0.6 3.8 1.1 2.3 0.6 3.8 0.4 1.6 0.6 3.4 0.4 36 16 37 255 0 0 0 0 12.4 0.1 13 12.2 05/13/2005 21:50:00 1.8 0.9 3.8 0.4 1.6 1 3.8 0.4 1.2 0.7 3.8 0.4 63 16 70 255 0 0 0 0 12.7 0 13.3 12.5 05/13/2005 22:00:00 1.9 0.9 4.2 0.4 1.7 1 4.2 0.4 1.1 0.8 3.4 0.4 77 29 52 255 0 0 0 0 12.4 0.1 13 11.9 05/13/2005 22:10:00 1.9 0.5 3 0.4 1.6 0.6 3 0.4 1 0.6 2.6 0.4 116 19 140 255 0 0 0 0 11.7 0 11.9 11.4 05/13/2005 22:20:00 2.3 0.4 3.4 1.1 2.1 0.4 3 0.7 1.4 0.5 2.6 0.4 96 9 95 255 0 0 0 0 11.1 0 11.4 10.9 05/13/2005 22:30:00 3.1 0.4 4.2 1.9 3 0.5 4.2 1.9 2 0.6 3.8 0.7 89 10 108 255 0 0 0 0 10.9 0 11.1 10.9 05/13/2005 22:40:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 1.1 1.4 0.6 3 0.4 81 12 86 255 0 0 0 0 10.6 0 10.9 10.6 05/13/2005 22:50:00 1.8 0.5 3 0.4 1.5 0.5 3 0.4 1.1 0.6 3.4 0.4 72 19 37 255 0 0 0 0 10.3 0.2 10.6 9.8 05/13/2005 23:00:00 2.1 0.4 3.4 1.1 1.9 0.5 3 0.7 1 0.5 2.3 0.4 91 9 100 255 0 0 0 0 9.6 0 9.8 9.3 05/13/2005 23:10:00 2.4 0.5 4.2 1.1 2.2 0.6 3.8 0.4 1.4 0.6 3.4 0.4 81 12 71 255 0 0 0 0 9.2 0.1 9.6 9 05/13/2005 23:20:00 1.9 0.6 3.4 0.4 1.6 0.6 3 0.4 0.9 0.5 2.6 0.4 69 10 69 255 0 0 0 0 8.7 0.2 9.3 8.5 05/13/2005 23:30:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 61 9 66 255 0 0 0 0 8.2 0 8.8 8.3 05/13/2005 23:40:00 2 0.4 3 1.1 1.8 0.5 3 0.7 1.2 0.4 2.3 0.4 60 8 61 255 0 0 0 0 8 0 8.3 7.8 05/13/2005 23:50:00 2.6 0.8 4.2 1.1 2.4 0.8 4.2 0.7 1.4 0.8 3.4 0.4 57 9 69 255 0 0 0 0 7.6 0 8.3 7.5 05/14/2005 00:00:00 2.5 0.7 4.9 0.7 2.3 0.8 4.9 0.4 1.6 0.7 3.4 0.4 53 14 52 255 0 0 0 0 7.8 0 8 7.5 05/14/2005 00:10:00 2.3 0.7 4.2 0.7 2.1 0.8 3.8 0.4 1.3 0.7 3.8 0.4 70 14 78 255 0 0 0 0 7.8 0.2 8.3 7.5 05/14/2005 00:20:00 2.6 0.8 4.6 0.7 2.5 0.8 4.2 0.7 1.4 0.6 3 0.4 76 12 77 255 0 0 0 0 8.1 0 8.3 8 05/14/2005 00:30:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 63 8 74 255 0 0 0 0 8.3 0 8.5 8 05/14/2005 00:40:00 2.5 0.5 3.8 1.5 2.3 0.5 3.4 1.1 1.4 0.4 2.3 0.4 87 6 101 255 0 0 0 0 8.4 0 8.5 8.3 05/14/2005 00:50:00 2.7 0.4 3.8 1.5 2.5 0.5 3.8 1.5 1.7 0.5 3 0.4 96 9 89 255 0 0 0 0 8.8 0.4 9.6 8.5 05/14/2005 01:00:00 2.7 0.6 4.6 1.1 2.5 0.6 4.9 0.7 1.8 0.7 3.4 0.4 83 13 61 255 0 0 0 0 9.8 0 10.1 9.6 05/14/2005 01:10:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.6 0.7 3 0.4 77 12 66 255 0 0 0 0 9.9 0 10.1 9.6 05/14/2005 01:20:00 3 0.6 4.9 1.9 2.9 0.6 5.3 0.7 2 0.7 3.8 0.4 81 16 65 255 0 0 0 0 9.3 0 9.6 9 05/14/2005 01:30:00 3.2 0.9 5.3 0.7 3.2 1 5.3 1.1 2.2 1 4.6 0.4 64 15 58 255 0 0 0 0 9.4 0 9.6 9.3 05/14/2005 01:40:00 2.8 0.7 4.6 1.5 2.7 0.7 4.6 1.1 1.9 0.8 3.8 0.4 63 20 101 255 0 0 0 0 9.4 0 9.6 9.3 05/14/2005 01:50:00 2.5 0.9 4.6 0.7 2.3 1 5.7 0.7 1.6 0.8 4.2 0.4 46 14 66 255 0 0 0 0 9.2 0.1 9.6 9 05/14/2005 02:00:00 2.7 0.6 4.2 1.1 2.5 0.6 4.2 0.4 1.8 0.8 3.8 0.4 45 13 37 255 0 0 0 0 9 0.1 9.3 8.8 05/14/2005 02:10:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 0.7 1.4 0.8 4.2 0.4 59 13 45 255 0 0 0 0 9.1 0 9.3 8.8 05/14/2005 02:20:00 2.4 0.7 4.2 0.7 2.3 0.8 3.8 0.4 1.4 0.9 3.8 0.4 69 15 53 255 0 0 0 0 8.7 0 9 8.5 05/14/2005 02:30:00 1.7 0.5 3 0.4 1.5 0.6 3 0.4 1 0.6 3 0.4 52 17 71 255 0 0 0 0 8.5 0 8.8 8.5 05/14/2005 02:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 59 6 67 255 0 0 0 0 8 0.1 8.5 7.8 05/14/2005 02:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 53 5 55 255 0 0 0 0 7.7 0 7.8 7.5 05/14/2005 03:00:00 1.1 0.7 3.4 0.4 0.8 0.6 3 0.4 0.5 0.4 1.9 0.4 15 24 345 255 0 0 0 0 7.4 0 7.5 7.3 05/14/2005 03:10:00 2.6 0.5 3.8 1.1 2.4 0.5 3.8 0.7 1 0.6 2.6 0.4 5 9 5 255 0 0 0 0 7.1 0 7.3 7 05/14/2005 03:20:00 2 0.6 3.4 0.4 1.7 0.7 3.4 0.4 0.8 0.5 2.3 0.4 327 27 350 255 0 0 0 0 6.8 0 7 6.7 05/14/2005 03:30:00 2.1 0.7 3.4 0.4 1.9 0.8 3 0.4 1 0.6 2.3 0.4 302 16 298 255 0 0 0 0 6.7 0 7 6.7 05/14/2005 03:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0 0.4 0.4 322 1 324 255 0 0 0 0 6.8 0 7 6.7 05/14/2005 03:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 17 20 37 255 0 0 0 0 6.9 0 7.3 6.7 05/14/2005 04:00:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 42 15 20 255 0 0 0 0 7.1 0 7.3 7 05/14/2005 04:10:00 2.3 1.3 6.5 0.4 2.1 1.4 6.5 0.4 1.4 1.1 4.6 0.4 48 19 45 255 0 0 0 0 7.2 0 7.5 7 05/14/2005 04:20:00 4.7 1.5 8 0.4 4.7 1.5 8 1.5 3.6 1.7 7.2 0.4 46 17 30 255 0 0 0 0 8.8 0.7 9.8 7.5 05/14/2005 04:30:00 5 0.9 8.4 3.4 4.9 0.9 8.8 3 4.1 1 7.2 1.9 29 11 19 255 0 0 0 0 10 0 10.3 9.8 05/14/2005 04:40:00 5.1 0.7 7.2 3 5 0.7 6.8 3 4.1 0.9 7.2 1.5 28 12 27 255 0 0 0 0 10.2 0 10.3 10.1 05/14/2005 04:50:00 5.1 1.1 8 2.3 5 1.1 7.6 1.9 3.6 1.2 6.8 0.7 20 12 16 255 0 0 0 0 10 0 10.1 9.8 05/14/2005 05:00:00 4.7 1 6.8 2.3 4.6 1 6.8 2.3 3.1 1.1 5.7 0.4 15 12 11 255 0 0 0 0 9.6 0.1 9.8 9.6 05/14/2005 05:10:00 5.2 1.1 7.6 2.3 5.1 1.1 7.2 1.9 3.8 1.4 7.2 0.4 18 14 15 255 0 0 0 0 9.6 0 9.6 9.3 05/14/2005 05:20:00 5 0.9 8 2.6 4.9 0.9 7.6 2.3 3.8 1.1 6.5 1.5 24 13 52 255 0 0 0 0 9.8 0 10.1 9.6 05/14/2005 05:30:00 5.2 1.1 8 3 5.1 1.1 8 2.6 4.1 1.1 7.2 1.9 20 12 359 255 0 0 0 0 10.2 0 10.6 9.8 05/14/2005 05:40:00 5.9 1.1 9.9 2.6 5.8 1.1 9.9 2.3 4.6 1.2 7.6 1.9 22 13 6 255 0 0 0 0 10.7 0.1 11.1 10.3 05/14/2005 05:50:00 5.3 1 8 2.6 5.3 1 8 2.6 4.1 1.2 7.2 1.5 18 12 18 255 0 0 0 0 10.9 0 11.1 10.6 05/14/2005 06:00:00 3.7 0.7 6.1 1.1 3.7 0.8 6.1 0.4 2.2 1 4.2 0.4 7 14 24 255 0 0 0 0 11.3 0 11.7 11.1 05/14/2005 06:10:00 3 0.9 5.3 1.1 2.8 1 5.3 0.4 1.6 1 3.8 0.4 353 19 2 255 0 0 0 0 12 0.2 12.2 11.4 05/14/2005 06:20:00 3.6 1 5.7 0.7 3.5 1 5.3 0.4 2.2 1.2 4.9 0.4 1 15 3 255 0 0 0 0 11.9 0.1 12.2 11.7 05/14/2005 06:30:00 3.4 0.9 6.5 1.5 3.3 1 6.5 0.7 2.1 1 5.7 0.4 1 15 359 255 0 0 0 0 11.7 0 11.9 11.7 05/14/2005 06:40:00 4.1 1.5 7.2 0.7 4 1.6 7.2 0.4 2.9 1.7 8 0.4 12 21 18 255 0 0 0 0 11.7 0 11.9 11.4 05/14/2005 06:50:00 4.2 1 7.6 1.9 4.1 1 7.6 1.5 2.8 1.1 6.1 0.4 19 18 347 255 0 0 0 0 11.9 0.1 12.5 11.4 05/14/2005 07:00:00 5.8 1.3 9.1 2.3 5.7 1.3 9.5 2.3 4.7 1.5 8.8 1.1 27 13 28 255 0 0 0 0 12.4 0.3 13 11.9 05/14/2005 07:10:00 6.9 1 9.9 3.8 6.9 1.1 9.9 3.8 5.6 1.2 8.8 2.6 32 13 39 255 0 0 0 0 12.9 0.2 13.5 12.5 05/14/2005 07:20:00 6.5 1 9.9 3.8 6.5 1 9.5 4.2 5.5 1.1 9.1 2.3 36 13 49 255 0 0 0 0 13.5 0 13.8 13.3 05/14/2005 07:30:00 6.2 1.1 9.5 3.4 6.1 1.2 9.1 2.6 5.1 1.4 8.8 1.1 23 14 22 255 0 0 0 0 14.2 0.1 14.6 13.8 05/14/2005 07:40:00 6 1.1 8 3.4 5.9 1.2 8.4 3.4 4.5 1.3 7.6 1.5 18 16 7 255 0 0 0 0 13.7 0.4 14.6 13 05/14/2005 07:50:00 4.4 1 6.5 1.9 4.3 1 6.8 1.9 3 1.3 6.1 0.4 12 15 3 255 0 0 0 0 13.1 0.2 13.5 12.7 05/14/2005 08:00:00 5.2 1.4 8 2.3 5.1 1.4 8.4 1.9 3.9 1.4 7.6 0.4 12 14 12 255 0 0 0 0 13 0.2 13.5 12.7 05/14/2005 08:10:00 4.6 1 7.2 2.3 4.5 1 7.2 1.9 3 1.3 6.1 0.4 5 16 4 255 0 0 0 0 12.9 0 13.3 12.7 05/14/2005 08:20:00 5.2 1 8 3 5.1 1 8 2.3 3.7 1.1 6.5 0.7 3 13 7 255 0 0 0 0 13.2 0 13.8 12.7 05/14/2005 08:30:00 5.7 1.2 8.8 2.6 5.6 1.2 9.1 2.3 4 1.3 7.2 1.1 8 16 1 255 0 0 0 0 13.5 0 14.1 13.3 05/14/2005 08:40:00 4.5 1 6.8 1.9 4.5 1.1 6.8 1.1 3.1 1.3 6.5 0.4 8 20 12 255 0 0 0 0 13.3 0 13.8 13.3 05/14/2005 08:50:00 4.7 1.1 7.6 2.3 4.6 1.1 7.6 1.9 3.6 1.1 6.8 1.1 18 14 12 255 0 0 0 0 13.5 0.1 13.8 13.3 05/14/2005 09:00:00 5.2 1.2 8.8 2.6 5.1 1.2 8.8 2.6 4 1.3 7.2 1.5 27 17 6 255 0 0 0 0 13.8 0.1 14.4 13.5 05/14/2005 09:10:00 4.3 0.9 7.2 2.3 4.2 0.9 6.8 2.6 3.3 1.1 6.1 1.1 21 11 30 255 0 0 0 0 14.3 0.2 15.2 13.8 05/14/2005 09:20:00 4.5 1 8.4 2.3 4.5 1 8 2.6 3.7 1.1 7.2 1.1 29 15 10 255 0 0 0 0 15 0 15.7 14.9 05/14/2005 09:30:00 2.3 1.2 4.6 0.4 2.2 1.2 4.6 0.4 1.8 1.1 4.2 0.4 0 36 32 255 0 0 0 0 14.7 0 15.5 14.6 05/14/2005 09:40:00 2.7 0.8 4.2 0.4 2.5 1 4.6 0.4 1.9 1 3.8 0.4 303 21 300 255 0 0 0 0 14.5 0.1 15.2 14.1 05/14/2005 09:50:00 2.8 0.8 4.6 0.7 2.7 0.8 4.2 0.4 2.4 0.9 4.6 0.4 299 19 292 255 0 0 0 0 14.6 0.3 15.7 14.4 05/14/2005 10:00:00 1.8 1 4.2 0.4 1.6 0.9 4.2 0.4 1.5 0.9 4.6 0.4 321 69 322 255 0 0 0 0 15.4 0.2 16 15.2 05/14/2005 10:10:00 1.6 0.8 3 0.4 1.4 0.8 3 0.4 1.1 0.8 3 0.4 331 45 31 255 0 0 0 0 16.3 0.2 16.8 15.7 05/14/2005 10:20:00 1.7 0.8 4.2 0.4 1.6 0.9 4.6 0.4 1.5 0.8 3 0.4 20 64 351 255 0 0 0 0 16.4 0.3 17.1 16.3 05/14/2005 10:30:00 1.9 1 4.2 0.4 1.6 1 4.6 0.4 1.4 1 3.8 0.4 322 43 25 255 0 0 0 0 16.8 0.1 17.1 16.6 05/14/2005 10:40:00 2.2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.4 0.8 3.8 0.4 6 33 9 255 0 0 0 0 17.5 0.1 18 17.1 05/14/2005 10:50:00 2.7 1 5.3 0.4 2.6 1.1 5.3 0.4 2 1.1 4.9 0.4 358 41 23 255 0 0 0 0 17.5 0.2 18.2 17.1 05/14/2005 11:00:00 3.6 0.8 6.1 1.5 3.5 0.9 6.1 1.1 2.7 1.1 6.5 0.4 8 27 33 255 0 0 0 0 18 0.1 18.5 17.7 05/14/2005 11:10:00 3 0.9 4.9 1.1 2.9 1 4.9 0.7 2.5 1 5.3 0.4 29 26 2 255 0 0 0 0 17.7 0.7 18.8 16.8 05/14/2005 11:20:00 2.7 1 4.9 0.4 2.7 1.1 5.3 0.4 2.3 1.1 4.9 0.4 42 28 14 255 0 0 0 0 17.8 0.3 18.5 16.8 05/14/2005 11:30:00 2.8 1 5.7 1.1 2.7 1 5.7 0.4 2.2 0.8 4.6 0.4 35 27 20 255 0 0 0 0 17.8 0.4 19.1 17.1 05/14/2005 11:40:00 4 0.9 6.1 1.9 3.9 0.9 6.1 1.5 2.8 1.1 6.1 0.4 6 17 340 255 0 0 0 0 19.4 0.2 20 18.5 05/14/2005 11:50:00 3.6 0.7 5.3 1.9 3.5 0.7 4.9 1.5 3 0.8 4.9 0.7 14 15 17 255 0 0 0 0 18.9 0.2 19.4 18.5 05/14/2005 12:00:00 2.9 1.1 5.3 0.4 2.8 1.2 4.9 0.4 2 1.1 4.6 0.4 12 22 6 255 0 0 0 0 18.9 0.3 19.4 18.2 05/14/2005 12:10:00 3.2 0.5 4.9 1.9 3.1 0.6 4.9 1.1 2.4 0.7 4.2 0.7 6 17 353 255 0 0 0 0 17.7 0.3 18.2 17.1 05/14/2005 12:20:00 2.3 0.8 4.6 0.7 2.1 0.9 4.2 0.4 1.7 0.8 3.4 0.4 14 17 12 255 0 0 0 0 17.1 0 17.4 16.8 05/14/2005 12:30:00 1.6 1.1 4.2 0.4 1.5 1.1 4.2 0.4 1.2 0.9 4.2 0.4 39 22 46 255 0 0 0 0 17.2 0 17.7 16.8 05/14/2005 12:40:00 1.7 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.2 0.8 3.8 0.4 287 76 292 255 0 0 0 0 16.8 0 17.4 16.6 05/14/2005 12:50:00 1.8 0.7 3.8 0.4 1.4 0.7 3.4 0.4 1.4 0.7 3 0.4 335 22 327 255 0 0 0 0 17.6 0.7 19.1 16.8 05/14/2005 13:00:00 1.6 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.9 0.7 3 0.4 306 26 289 255 0 0 0 0 18.2 0.3 19.1 17.4 05/14/2005 13:10:00 2 0.8 3.4 0.4 1.8 0.9 3.4 0.4 1.6 0.9 3.8 0.4 304 27 318 255 0 0 0 0 17.5 0.2 18.5 17.1 05/14/2005 13:20:00 1.2 0.7 3 0.4 0.9 0.7 3 0.4 0.9 0.8 3.4 0.4 302 28 294 255 0 0 0 0 17.5 0.3 18.5 17.1 05/14/2005 13:30:00 2 1.1 4.2 0.4 1.9 1.1 4.2 0.4 1.2 0.8 3.4 0.4 25 35 11 255 0 0 0 0 17.2 0.2 18 16.8 05/14/2005 13:40:00 1.1 0.7 3 0.4 1 0.7 2.6 0.4 0.8 0.6 3 0.4 52 29 27 255 0 0 0 0 18 0.2 18.5 17.7 05/14/2005 13:50:00 1.5 0.9 3.8 0.4 1.3 0.9 3.4 0.4 1 0.8 3.8 0.4 0 43 314 255 0 0 0 0 18.1 0.3 18.8 17.4 05/14/2005 14:00:00 1.7 1 3.8 0.4 1.5 1 3.8 0.4 1.1 0.8 3.8 0.4 11 94 12 255 0 0 0 0 17.9 0.3 18.8 17.1 05/14/2005 14:10:00 2.3 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.8 0.8 3.4 0.4 315 28 322 255 0 0 0 0 17 0.1 17.7 16.8 05/14/2005 14:20:00 1.2 0.7 3 0.4 0.9 0.6 3 0.4 0.8 0.6 2.6 0.4 10 45 345 255 0 0 0 0 17.3 0 17.4 17.1 05/14/2005 14:30:00 0.5 0.4 2.3 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 204 79 81 255 0 0 0 0 16.9 0 17.1 16.8 05/14/2005 14:40:00 2.2 0.6 3.8 0.7 1.8 0.6 3.4 0.4 1.2 0.7 3 0.4 335 32 357 255 0 0 0 0 17.1 0.1 17.4 16.8 05/14/2005 14:50:00 2.5 0.7 4.2 0.4 2.2 0.8 4.2 0.4 1.5 0.8 3.4 0.4 358 20 355 255 0 0 0 0 17.2 0 17.4 17.1 05/14/2005 15:00:00 3 0.7 4.9 1.5 2.8 0.7 4.9 1.5 2.2 0.8 4.2 0.4 30 15 23 255 0 0 0 0 17.1 0 17.1 16.8 05/14/2005 15:10:00 1.1 0.8 3 0.4 1 0.8 3 0.4 1 0.7 3 0.4 9 28 21 255 0 0 0 0 17.2 0 17.1 17.1 05/14/2005 15:20:00 1.2 0.9 4.2 0.4 1.1 1 4.2 0.4 0.9 0.8 3.4 0.4 205 56 223 255 0 0 0 0 17.3 0 17.4 17.1 05/14/2005 15:30:00 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 235 39 251 255 0 0 0 0 17.5 0.1 18 17.1 05/14/2005 15:40:00 1.2 1 4.6 0.4 1.1 1.1 4.9 0.4 0.8 0.8 4.6 0.4 223 76 253 255 0 0 0 0 18.7 0.2 19.1 18 05/14/2005 15:50:00 3.7 1.1 6.8 0.7 3.6 1.2 6.5 0.7 3 1.2 6.1 0.4 286 23 256 255 0 0 0 0 19.2 0 19.4 19.1 05/14/2005 16:00:00 4.5 1.1 8 1.5 4.3 1.2 8 0.4 3.4 1.3 6.5 0.4 303 29 286 255 0 0 0 0 19 0.1 19.4 18.8 05/14/2005 16:10:00 4.1 1.5 6.8 0.4 3.9 1.7 6.8 0.4 3.2 1.5 6.8 0.4 290 27 289 255 0 0 0 0 18.8 0.2 19.4 18.5 05/14/2005 16:20:00 3.5 1.4 6.5 0.4 3.2 1.5 6.8 0.4 2.5 1.5 6.5 0.4 310 26 283 255 0 0 0 0 18.5 0.2 19.1 18.2 05/14/2005 16:30:00 3.4 1 6.5 1.1 3.3 1.2 6.5 0.4 2.5 1.2 5.3 0.4 256 35 248 255 0 0 0 0 18.5 0.2 19.1 18.2 05/14/2005 16:40:00 2.9 1.5 6.1 0.4 2.8 1.5 6.1 0.4 2.3 1.5 6.5 0.4 265 38 282 255 0 0 0 0 18.5 0.2 19.1 18.2 05/14/2005 16:50:00 3.5 1.1 6.5 1.1 3.4 1.1 6.1 0.7 2.9 1.3 5.7 0.4 248 29 234 255 0 0 0 0 18.5 0.2 19.1 18.2 05/14/2005 17:00:00 4.1 1.5 8 1.5 3.9 1.5 7.6 1.1 2.9 1.5 7.2 0.4 261 26 249 255 0 0 0 0 18.1 0.2 18.8 18 05/14/2005 17:10:00 3.8 1.2 6.5 0.7 3.8 1.4 6.5 0.4 3.1 1.3 6.5 0.4 252 27 253 255 0 0 0 0 17.8 0.2 18.5 17.4 05/14/2005 17:20:00 3.7 1.3 6.8 0.7 3.5 1.3 6.8 0.4 2.6 1.3 6.5 0.4 253 30 232 255 0 0 0 0 17.5 0 18 17.4 05/14/2005 17:30:00 4.9 1.2 8 1.5 4.7 1.3 7.6 1.9 3.8 1.3 6.8 0.4 261 23 268 255 0 0 0 0 17.3 0.1 18 17.1 05/14/2005 17:40:00 3.7 1.6 8 0.7 3.6 1.7 7.6 0.4 2.4 1.5 7.6 0.4 261 29 272 255 0 0 0 0 17 0 17.4 16.8 05/14/2005 17:50:00 3.9 1.3 7.6 1.1 3.8 1.4 7.6 0.7 3 1.3 7.2 0.4 270 29 262 255 0 0 0 0 17.1 0 17.1 16.8 05/14/2005 18:00:00 3.8 1.4 8.4 0.4 3.7 1.5 8 0.4 2.8 1.5 7.2 0.4 261 27 269 255 0 0 0 0 17.1 0 17.1 16.8 05/14/2005 18:10:00 4.1 1.7 8 0.4 4.1 1.8 8 0.4 3 1.7 6.8 0.4 252 23 226 255 0 0 0 0 17 0 17.1 16.8 05/14/2005 18:20:00 3.5 1.2 6.5 1.1 3.4 1.3 6.5 0.7 2.8 1.4 6.1 0.4 259 33 255 255 0 0 0 0 16.7 0 16.8 16.6 05/14/2005 18:30:00 4.5 1.5 8 1.1 4.5 1.6 8 0.7 3.4 1.5 7.2 0.4 269 22 267 255 0 0 0 0 16.6 0 16.8 16.3 05/14/2005 18:40:00 3.8 1.3 7.2 0.4 3.6 1.3 6.8 0.4 2.7 1.3 6.8 0.4 279 26 287 255 0 0 0 0 16.1 0 16.6 16 05/14/2005 18:50:00 4.1 1.5 8 0.7 4 1.5 7.6 0.4 3 1.6 7.6 0.4 281 24 271 255 0 0 0 0 15.7 0 16 15.7 05/14/2005 19:00:00 3.8 1 6.1 1.1 3.7 1.1 6.5 1.1 2.8 1.2 5.7 0.4 281 21 276 255 0 0 0 0 15.6 0 16 15.5 05/14/2005 19:10:00 3 1 5.7 0.7 2.7 1.1 5.3 0.4 2.3 1 4.9 0.4 281 19 280 255 0 0 0 0 15.5 0 15.7 15.5 05/14/2005 19:20:00 3.8 1.2 8 1.5 3.6 1.2 8 1.1 2.4 1.3 6.5 0.4 287 23 278 255 0 0 0 0 15.3 0.1 15.7 15.2 05/14/2005 19:30:00 3.1 1.3 6.5 0.4 2.9 1.4 6.8 0.4 2.1 1.1 5.7 0.4 272 27 269 255 0 0 0 0 15 0 15.7 14.9 05/14/2005 19:40:00 3.2 1 6.1 1.1 3 1 6.1 0.7 2.2 1.1 4.9 0.4 277 28 302 255 0 0 0 0 15 0 15.7 15.2 05/14/2005 19:50:00 3.4 1.1 6.1 0.7 3.3 1.3 6.5 0.4 2.4 1.2 5.7 0.4 289 23 290 255 0 0 0 0 15.2 0.1 15.7 15.2 05/14/2005 20:00:00 3.9 1.2 6.5 0.4 3.8 1.3 6.8 0.4 2.9 1.2 6.1 0.4 293 21 317 255 0 0 0 0 15.1 0 15.7 14.9 05/14/2005 20:10:00 4.1 1.2 7.2 1.5 3.9 1.2 6.8 0.7 2.9 1.3 6.8 0.4 292 18 288 255 0 0 0 0 14.8 0.1 15.5 14.6 05/14/2005 20:20:00 4 1.1 6.8 1.1 3.8 1.1 6.5 1.1 3.1 1.3 6.1 0.4 287 19 276 255 0 0 0 0 14.6 0 15.2 14.6 05/14/2005 20:30:00 3.7 1.2 7.6 0.7 3.5 1.2 7.6 0.7 2.4 1.1 4.6 0.4 287 20 281 255 0 0 0 0 14.4 0 15.2 14.4 05/14/2005 20:40:00 3.4 1.3 6.5 0.7 3.3 1.3 6.1 0.4 2.6 1.3 5.7 0.4 282 22 288 255 0 0 0 0 14.2 0.1 14.6 13.8 05/14/2005 20:50:00 2.9 1 5.3 0.7 2.8 1 5.3 0.4 2.1 1.2 4.9 0.4 282 21 264 255 0 0 0 0 14 0.1 14.6 13.8 05/14/2005 21:00:00 2.9 1.3 6.1 0.4 2.8 1.4 6.5 0.4 2 1.3 5.3 0.4 275 23 255 255 0 0 0 0 13.9 0 14.4 13.5 05/14/2005 21:10:00 3.2 0.8 6.1 1.1 3 0.9 6.1 1.1 2 1 5.7 0.4 280 21 292 255 0 0 0 0 13.6 0 14.1 13.3 05/14/2005 21:20:00 3 1.2 6.5 0.4 2.8 1.2 6.5 0.4 1.8 1.1 5.7 0.4 281 26 275 255 0 0 0 0 13.4 0 13.8 13.3 05/14/2005 21:30:00 2.8 1.1 5.7 0.7 2.7 1.3 5.7 0.4 1.6 1.2 4.9 0.4 274 30 291 255 0 0 0 0 13.3 0 13.5 13 05/14/2005 21:40:00 3.3 1 5.7 0.7 3.2 1.1 6.1 0.4 2.1 1.1 4.9 0.4 266 22 259 255 0 0 0 0 13.1 0 13.5 13 05/14/2005 21:50:00 3.1 1.4 6.8 0.4 3.1 1.4 6.5 0.4 2.1 1.3 6.1 0.4 259 30 267 255 0 0 0 0 13.1 0 13.5 12.7 05/14/2005 22:00:00 2.3 1.2 4.9 0.4 2.2 1.3 4.9 0.4 1.6 1.1 4.9 0.4 272 26 240 255 0 0 0 0 12.9 0 13.3 12.7 05/14/2005 22:10:00 4 1.5 7.6 1.1 3.9 1.6 7.2 0.4 3.1 1.5 6.8 0.4 273 26 259 255 0 0 0 0 12.7 0 13.3 12.5 05/14/2005 22:20:00 4.2 1.6 8.4 1.1 4.1 1.7 8 0.7 3 1.5 7.2 0.4 279 27 287 255 0 0 0 0 12.4 0 12.7 12.2 05/14/2005 22:30:00 3.2 1.6 7.2 0.4 3.1 1.7 6.8 0.4 2.3 1.5 7.2 0.4 262 24 256 255 0 0 0 0 12 0.1 12.5 11.7 05/14/2005 22:40:00 3.9 1.2 8 1.1 3.8 1.3 7.6 0.4 2.7 1.5 7.6 0.4 262 22 272 255 0 0 0 0 11.7 0 12.2 11.4 05/14/2005 22:50:00 4.2 1.3 7.2 1.5 4.1 1.5 7.6 1.1 3 1.3 6.5 0.4 257 17 253 255 0 0 0 0 11.3 0 11.7 11.1 05/14/2005 23:00:00 3.3 1.2 6.5 0.7 3.2 1.3 6.8 0.7 2.2 1.3 6.8 0.4 247 26 240 255 0 0 0 0 10.8 0.1 11.4 10.6 05/14/2005 23:10:00 2.8 1 5.7 0.7 2.7 1 5.7 0.4 2 1 4.9 0.4 239 15 228 255 0 0 0 0 10.6 0 10.9 10.6 05/14/2005 23:20:00 1.6 0.8 4.9 0.4 1.4 0.9 4.6 0.4 0.8 0.8 3.8 0.4 241 19 256 255 0 0 0 0 10.4 0 10.6 10.3 05/14/2005 23:30:00 1.4 0.8 3.4 0.4 1.3 0.8 3 0.4 0.6 0.5 2.6 0.4 237 17 227 255 0 0 0 0 10.2 0 10.3 10.1 05/14/2005 23:40:00 1.3 0.5 2.6 0.4 1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 235 13 225 255 0 0 0 0 10.1 0 10.3 10.1 05/14/2005 23:50:00 0.7 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 221 20 229 255 0 0 0 0 10 0 10.1 9.8 05/15/2005 00:00:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 224 10 248 255 0 0 0 0 9.8 0 10.1 9.6 05/15/2005 00:10:00 1.2 0.6 3.4 0.4 0.9 0.6 3 0.4 0.5 0.4 2.6 0.4 238 22 244 255 0 0 0 0 9.7 0 9.8 9.6 05/15/2005 00:20:00 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 234 8 242 255 0 0 0 0 9.6 0 9.6 9.6 05/15/2005 00:30:00 0.8 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.4 0.1 0.7 0.4 228 9 206 255 0 0 0 0 9.4 0 9.6 9.3 05/15/2005 00:40:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 0.7 0.5 3 0.4 219 13 212 255 0 0 0 0 9.2 0 9.6 9 05/15/2005 00:50:00 2.7 1 4.9 0.7 2.5 1 4.9 0.4 1.6 1.1 4.2 0.4 226 20 216 255 0 0 0 0 9.4 0.1 9.6 9 05/15/2005 01:00:00 2.3 0.9 4.2 0.4 2.2 1 4.6 0.4 1.1 0.8 3.8 0.4 240 23 220 255 0 0 0 0 9.6 0 9.8 9.6 05/15/2005 01:10:00 3 1.2 5.7 0.4 2.9 1.3 6.1 0.7 1.9 1.2 5.7 0.4 234 18 255 255 0 0 0 0 9.6 0 9.8 9.6 05/15/2005 01:20:00 3.2 1.2 6.1 0.4 3.1 1.2 6.5 0.4 2.1 1.2 6.1 0.4 252 22 264 255 0 0 0 0 9.6 0 9.8 9.6 05/15/2005 01:30:00 2.8 1.2 6.1 0.4 2.9 1.3 5.7 0.4 1.7 1.1 4.9 0.4 258 30 252 255 0 0 0 0 9.5 0 9.6 9.3 05/15/2005 01:40:00 1.5 0.9 4.2 0.4 1.2 0.9 3.8 0.4 0.8 0.6 3.4 0.4 261 23 280 255 0 0 0 0 9.5 0 9.6 9.3 05/15/2005 01:50:00 2.5 0.8 4.6 0.4 2.4 1 4.6 0.4 1.5 0.9 3.8 0.4 259 16 285 255 0 0 0 0 9.4 0 9.6 9.3 05/15/2005 02:00:00 2.2 1 4.6 0.4 2 1 4.6 0.4 1 0.8 4.6 0.4 250 18 261 255 0 0 0 0 9.2 0 9.3 9.3 05/15/2005 02:10:00 1.9 0.8 4.2 0.4 1.8 0.8 4.2 0.4 1.1 0.8 3.4 0.4 248 20 261 255 0 0 0 0 9.2 0 9.3 9 05/15/2005 02:20:00 1.2 0.6 3 0.4 1 0.6 2.6 0.4 0.7 0.5 3 0.4 234 18 252 255 0 0 0 0 9 0 9.3 9 05/15/2005 02:30:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 251 12 263 255 0 0 0 0 8.9 0 9.3 8.8 05/15/2005 02:40:00 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.4 0.2 1.5 0.4 251 7 252 255 0 0 0 0 8.7 0.1 9 8.5 05/15/2005 02:50:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 239 8 255 255 0 0 0 0 8.2 0 8.5 8 05/15/2005 03:00:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.5 0.3 1.9 0.4 245 8 246 255 0 0 0 0 7.8 0 8 7.5 05/15/2005 03:10:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 0.7 0.4 1.9 0.4 244 6 243 255 0 0 0 0 7.5 0 7.8 7.3 05/15/2005 03:20:00 1.6 0.3 2.3 0.7 1.5 0.3 1.9 0.7 0.5 0.2 1.1 0.4 233 5 243 255 0 0 0 0 7.3 0 7.5 7.3 05/15/2005 03:30:00 1.8 0.3 2.6 1.1 1.7 0.3 2.6 0.7 0.7 0.4 1.9 0.4 232 5 233 255 0 0 0 0 7.3 0 7.3 7.3 05/15/2005 03:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 0.7 0.4 256 13 240 255 0 0 0 0 7.2 0 7.3 7.3 05/15/2005 03:50:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 253 1 253 255 0 0 0 0 7.2 0 7.3 7 05/15/2005 04:00:00 1.2 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.4 0 0.7 0.4 250 6 251 255 0 0 0 0 7.1 0 7.3 7 05/15/2005 04:10:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 0.4 0.1 1.1 0.4 250 4 252 255 0 0 0 0 7.1 0 7.3 7 05/15/2005 04:20:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 252 3 255 255 0 0 0 0 7.1 0 7.3 7 05/15/2005 04:30:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 249 0 250 255 0 0 0 0 7.1 0 7.3 7 05/15/2005 04:40:00 0.7 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 254 2 250 255 0 0 0 0 7 0 7.3 7 05/15/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 0 0 0 0 7.1 0 7.3 7 05/15/2005 05:00:00 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 249 20 255 255 0 0 0 0 7.1 0 7.3 7 05/15/2005 05:10:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 231 1 233 255 0 0 0 0 7.3 0 7.3 7.3 05/15/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 230 0 255 255 0 0 0 0 7.3 0 7.5 7.3 05/15/2005 05:30:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 230 0 230 255 0 0 0 0 7.4 0 7.5 7.3 05/15/2005 05:40:00 1.2 0.3 1.9 0.4 1 0.3 1.9 0.4 0.4 0.1 0.7 0.4 223 5 230 255 0 0 0 0 7.6 0 7.8 7.5 05/15/2005 05:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 233 10 243 255 0 0 0 0 7.8 0 8 7.8 05/15/2005 06:00:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 247 12 234 255 0 0 0 0 8 0 8 7.8 05/15/2005 06:10:00 1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.5 0.3 1.9 0.4 250 13 253 255 0 0 0 0 8 0 8.3 8 05/15/2005 06:20:00 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 266 9 233 255 0 0 0 0 8.1 0 8.3 8 05/15/2005 06:30:00 1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.5 0.4 1.9 0.4 247 13 263 255 0 0 0 0 8.1 0 8.3 8.3 05/15/2005 06:40:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 252 17 247 255 0 0 0 0 8.1 0 8.3 8 05/15/2005 06:50:00 1.2 0.8 3.4 0.4 1 0.8 3.4 0.4 0.7 0.7 3.4 0.4 244 16 253 255 0 0 0 0 8.1 0 8.3 8.3 05/15/2005 07:00:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 0.8 0.6 2.3 0.4 245 14 251 255 0 0 0 0 8.1 0 8.3 8 05/15/2005 07:10:00 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.4 1.9 0.4 254 27 251 255 0 0 0 0 8 0 8.3 8 05/15/2005 07:20:00 1.3 0.7 3 0.4 1.1 0.7 3 0.4 0.7 0.4 1.9 0.4 256 15 255 255 0 0 0 0 8 0 8.3 8 05/15/2005 07:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 261 7 247 255 0 0 0 0 8 0 8.3 8 05/15/2005 07:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 22 260 255 0 0 0 0 8.1 0 8.3 8 05/15/2005 07:50:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 284 15 282 255 0 0 0 0 8.3 0 8.5 8.3 05/15/2005 08:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 254 8 263 255 0 0 0 0 8.4 0 8.5 8.3 05/15/2005 08:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 271 15 264 255 0 0 0 0 8.4 0 8.5 8.3 05/15/2005 08:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 288 8 294 255 0 0 0 0 8.5 0 8.8 8.5 05/15/2005 08:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 291 28 321 255 0 0 0 0 8.7 0 9 8.5 05/15/2005 08:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 308 16 320 255 0 0 0 0 8.9 0 9 8.8 05/15/2005 08:50:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 291 30 317 255 0 0 0 0 9 0 9.3 9 05/15/2005 09:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 276 30 262 255 0 0 0 0 9.4 0 9.6 9 05/15/2005 09:10:00 1.1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 291 32 306 255 0 0 0 0 9.4 0 9.6 9.3 05/15/2005 09:20:00 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 325 35 293 255 0 0 0 0 9.2 0 9.3 9 05/15/2005 09:30:00 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 303 15 311 255 0 0 0 0 9.4 0 9.6 9 05/15/2005 09:40:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 301 15 297 255 0 0 0 0 9.4 0 9.6 9.3 05/15/2005 09:50:00 1.6 0.7 3 0.4 1.4 0.7 3 0.4 1 0.7 2.6 0.4 307 15 311 255 0 0 0 0 9.5 0 9.6 9.3 05/15/2005 10:00:00 1.6 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 300 12 311 255 0 0 0 0 9.6 0 9.6 9.6 05/15/2005 10:10:00 1.4 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 283 22 307 255 0 0 0 0 9.6 0 9.6 9.6 05/15/2005 10:20:00 1.2 0.5 2.6 0.4 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 299 15 296 255 0 0 0 0 9.6 0 9.8 9.6 05/15/2005 10:30:00 1 0.5 2.6 0.4 0.7 0.4 2.3 0.4 0.6 0.3 1.9 0.4 306 16 327 255 0 0 0 0 9.8 0 10.1 9.8 05/15/2005 10:40:00 1.3 0.7 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 320 22 323 255 0 0 0 0 9.9 0 10.1 9.8 05/15/2005 10:50:00 1.7 0.6 3 0.4 1.4 0.6 2.6 0.4 1.1 0.7 2.6 0.4 305 20 322 255 0 0 0 0 10.1 0 10.3 9.8 05/15/2005 11:00:00 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 1.1 0.6 2.6 0.4 289 22 286 255 0 0 0 0 10 0 10.1 9.8 05/15/2005 11:10:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 302 26 309 255 0 0 0 0 10 0 10.3 10.1 05/15/2005 11:20:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 299 23 310 255 0 0 0 0 10.1 0 10.3 9.8 05/15/2005 11:30:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 294 27 318 255 0 0 0 0 10.2 0 10.3 10.1 05/15/2005 11:40:00 1.5 0.7 3 0.4 1.3 0.8 3 0.4 1 0.7 3 0.4 301 20 308 255 0 0 0 0 10.3 0 10.6 10.3 05/15/2005 11:50:00 1.5 0.6 3.4 0.4 1.2 0.6 2.6 0.4 0.8 0.5 2.6 0.4 300 22 322 255 0 0 0 0 10.2 0 10.3 10.1 05/15/2005 12:00:00 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.6 0.4 302 21 333 255 10.3 0 10.6 10.3 05/15/2005 12:10:00 1.3 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 312 7 309 255 10.6 0 11.1 10.6 05/15/2005 12:20:00 1.1 0.7 3 0.4 0.9 0.6 2.3 0.4 0.7 0.4 2.3 0.4 305 23 294 255 10.8 0 11.4 10.6 05/15/2005 12:30:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 256 30 262 255 10.8 0.1 11.4 10.6 05/15/2005 12:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 208 14 196 255 10.6 0 11.1 10.3 05/15/2005 12:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 185 30 178 255 10.7 0.1 11.4 10.6 05/15/2005 13:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 207 22 193 255 10.9 0.1 11.4 10.6 05/15/2005 13:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 180 47 155 255 10.7 0 11.1 10.6 05/15/2005 13:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 269 76 184 255 11.1 0 11.7 10.9 05/15/2005 13:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 242 27 167 255 11.3 0 11.7 11.1 05/15/2005 13:40:00 0.7 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 94 112 8 255 11.7 0.1 12.2 11.4 05/15/2005 13:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.5 0.4 219 86 331 255 11.9 0.2 12.5 11.7 05/15/2005 14:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 27 107 284 255 11.8 0.1 12.2 11.7 05/15/2005 14:10:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 336 41 305 255 11.9 0.1 12.5 11.7 05/15/2005 14:20:00 2 0.6 3.8 0.4 1.9 0.7 3.8 0.4 1.4 0.7 3 0.4 281 17 281 255 11.9 0.1 12.5 11.7 05/15/2005 14:30:00 1.3 0.7 2.6 0.4 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 316 28 334 255 12.3 0.1 12.7 12.2 05/15/2005 14:40:00 1.9 0.6 3.8 0.4 1.8 0.7 3.8 0.4 1.2 0.7 3 0.4 289 20 295 255 12 0 12.5 11.9 05/15/2005 14:50:00 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.6 0.5 2.6 0.4 305 16 310 255 12.1 0 12.5 11.9 05/15/2005 15:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 3 38 14 255 12.1 0 12.5 11.9 05/15/2005 15:10:00 1.2 0.7 3 0.4 1 0.7 3 0.4 0.7 0.5 2.3 0.4 12 45 337 255 12.2 0 12.5 11.9 05/15/2005 15:20:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 24 36 16 255 11.8 0.1 12.2 11.7 05/15/2005 15:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 57 15 82 255 11.7 0 12.2 11.4 05/15/2005 15:40:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.5 0.3 1.9 0.4 17 41 12 255 11.9 0.1 12.5 11.7 05/15/2005 15:50:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.4 2.3 0.4 325 41 298 255 12.1 0 12.5 11.9 05/15/2005 16:00:00 1.3 0.8 3 0.4 1.1 0.8 3.4 0.4 0.9 0.6 3 0.4 329 22 1 255 12.1 0 12.5 11.9 05/15/2005 16:10:00 0.9 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 337 29 329 255 12.1 0 12.5 11.9 05/15/2005 16:20:00 1 0.8 3 0.4 0.8 0.6 2.6 0.4 0.8 0.6 2.3 0.4 335 24 339 255 12.1 0 12.5 11.9 05/15/2005 16:30:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 43 82 1 255 11.8 0.1 12.2 11.7 05/15/2005 16:40:00 1.2 0.7 3.4 0.4 0.9 0.6 3 0.4 0.6 0.4 2.3 0.4 339 17 10 255 11.9 0.1 12.5 11.7 05/15/2005 16:50:00 0.6 0.3 2.3 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 328 22 1 255 11.9 0.1 12.5 11.7 05/15/2005 17:00:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 306 8 293 255 11.7 0 12.2 11.7 05/15/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 39 255 255 11.7 0 12.2 11.7 05/15/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 85 4 255 255 11.7 0 11.9 11.4 05/15/2005 17:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 42 30 43 255 11.7 0.1 12.2 11.7 05/15/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 56 255 255 11.7 0 12.2 11.7 05/15/2005 17:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 64 27 39 255 12.1 0 12.2 11.9 05/15/2005 18:00:00 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 354 22 331 255 12.1 0 12.2 11.9 05/15/2005 18:10:00 0.7 0.6 2.6 0.4 0.6 0.6 2.3 0.4 0.6 0.5 2.6 0.4 51 61 142 255 12.1 0 12.2 11.9 05/15/2005 18:20:00 1.9 0.6 3.4 0.4 1.9 0.6 3 0.4 1.5 0.7 3 0.4 153 17 147 255 11.7 0 11.9 11.4 05/15/2005 18:30:00 2.2 0.7 3.4 0.4 2.1 0.7 3.4 0.4 1.5 0.8 3.4 0.4 141 17 129 255 11.5 0 11.7 11.4 05/15/2005 18:40:00 2.5 0.8 4.6 0.7 2.4 0.8 4.6 0.4 2.1 0.7 3.8 0.4 146 22 141 255 11.3 0 11.4 11.4 05/15/2005 18:50:00 2.4 0.9 4.6 0.4 2.3 0.9 4.2 0.4 2 0.9 4.2 0.4 145 11 139 255 11.2 0 11.4 11.1 05/15/2005 19:00:00 2 0.6 3 0.4 1.9 0.6 3.4 0.4 1.4 0.7 3 0.4 147 15 158 255 11.1 0 11.4 11.1 05/15/2005 19:10:00 2.2 0.7 3.8 0.7 2.1 0.7 3.8 0.4 1.5 0.9 3.4 0.4 146 22 118 255 11.1 0 11.1 11.1 05/15/2005 19:20:00 2.7 0.8 4.2 0.7 2.6 0.9 4.2 0.4 2 0.9 4.2 0.4 133 17 143 255 11.1 0 11.1 11.1 05/15/2005 19:30:00 2.5 0.6 4.2 0.4 2.4 0.6 3.8 0.7 1.8 0.8 3.4 0.4 136 15 130 255 11.1 0 11.1 11.1 05/15/2005 19:40:00 2.4 0.7 4.2 0.7 2.3 0.7 3.8 0.7 1.7 0.7 3.4 0.4 129 15 99 255 11 0 11.1 10.9 05/15/2005 19:50:00 1.2 0.6 3 0.4 1 0.5 2.6 0.4 0.7 0.4 2.3 0.4 113 15 99 255 10.9 0 11.1 10.9 05/15/2005 20:00:00 1.8 0.5 3 0.4 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 112 11 106 255 10.8 0 10.9 10.6 05/15/2005 20:10:00 1.4 0.2 1.9 0.7 1.2 0.3 1.9 0.7 0.9 0.4 1.9 0.4 99 13 114 255 10.5 0 10.9 10.3 05/15/2005 20:20:00 1.8 0.3 2.3 0.7 1.7 0.4 2.3 0.4 1.3 0.4 1.9 0.4 117 9 102 255 10.3 0.1 10.6 10.3 05/15/2005 20:30:00 1.6 0.4 3 0.4 1.3 0.5 2.6 0.4 0.9 0.4 2.3 0.4 63 26 35 255 10.1 0 10.3 9.8 05/15/2005 20:40:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 91 10 90 255 9.4 0.2 9.8 9 05/15/2005 20:50:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.8 0.4 1.9 0.4 78 18 48 255 8.7 0.1 9 8.5 05/15/2005 21:00:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.7 0.4 2.3 0.4 69 16 100 255 8.3 0 8.5 8 05/15/2005 21:10:00 1.1 0.4 2.6 0.4 0.9 0.5 2.6 0.4 0.4 0.2 1.5 0.4 65 13 77 255 7.8 0.1 8.3 7.5 05/15/2005 21:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 85 24 90 255 7.4 0 7.5 7.3 05/15/2005 21:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 0.7 0.4 77 9 70 255 7 0.1 7.3 6.7 05/15/2005 21:40:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 64 15 61 255 6.5 0.1 6.7 6.2 05/15/2005 21:50:00 0.9 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 61 9 84 255 6.1 0 6.2 5.7 05/15/2005 22:00:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 72 10 79 255 5.8 0 6 5.7 05/15/2005 22:10:00 1 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.3 1.5 0.4 74 3 79 255 5.4 0.1 5.7 5.2 05/15/2005 22:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 72 0 72 255 5.1 0 5.2 5 05/15/2005 22:30:00 1.4 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.5 0.3 1.1 0.4 78 4 82 255 4.7 0.1 5 4.3 05/15/2005 22:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 13 43 331 255 4.1 0.1 4.5 4 05/15/2005 22:50:00 0.8 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.8 0.7 2.3 0.4 289 66 201 255 3.9 0 4 3.8 05/15/2005 23:00:00 1.7 0.5 3 0.7 1.9 0.4 3 0.7 1.1 0.5 2.3 0.4 185 7 187 255 3.8 0 4 3.8 05/15/2005 23:10:00 1.6 0.3 2.6 0.7 2.3 0.3 3 1.5 1.3 0.4 1.9 0.4 174 4 170 255 3.6 0 3.8 3.5 05/15/2005 23:20:00 1.8 0.4 2.6 0.7 2.2 0.6 3.4 0.7 1.2 0.6 2.6 0.4 177 13 173 255 3.6 0 3.8 3.5 05/15/2005 23:30:00 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 216 4 222 255 3.5 0 3.8 3.5 05/15/2005 23:40:00 1.4 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 202 9 208 255 3.8 0 4 3.5 05/15/2005 23:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 188 0 188 255 4 0 4.3 3.8 05/16/2005 00:00:00 0.7 0.5 1.9 0.4 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 184 3 183 255 4.3 0 4.5 4 05/16/2005 00:10:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.6 0.3 1.5 0.4 188 5 189 255 4.4 0 4.5 4.3 05/16/2005 00:20:00 0.9 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 197 5 192 255 4.1 0 4.3 3.8 05/16/2005 00:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 202 0 202 255 3.6 0.1 4 3.5 05/16/2005 00:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 100 53 71 255 3.5 0 3.5 3.5 05/16/2005 00:50:00 1.2 0.3 1.9 0.4 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 80 5 81 255 3.4 0 3.8 3.3 05/16/2005 01:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 89 0 89 255 3.3 0 3.5 3.3 05/16/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 255 255 3.4 0 3.5 3.3 05/16/2005 01:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 106 26 149 255 3.4 0 3.5 3.3 05/16/2005 01:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 157 9 155 255 3.4 0 3.8 3.3 05/16/2005 01:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 139 255 3.2 0 3.5 3.3 05/16/2005 01:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 139 255 3.3 0 3.5 3.3 05/16/2005 02:00:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 139 0 139 255 3.4 0 3.5 3.3 05/16/2005 02:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 131 2 138 255 3.7 0 4 3.5 05/16/2005 02:20:00 0.9 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 141 8 146 255 3.8 0 4.3 3.8 05/16/2005 02:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 137 0 137 255 4 0 4.3 3.8 05/16/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 255 255 4 0 4 3.8 05/16/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 255 255 4 0 4 3.8 05/16/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 141 5 255 255 3.8 0 4 3.5 05/16/2005 03:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 155 6 163 255 3.6 0 3.8 3.5 05/16/2005 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 127 24 148 255 3.6 0 3.8 3.5 05/16/2005 03:30:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 94 6 96 255 3.5 0 3.8 3.5 05/16/2005 03:40:00 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 77 1 76 255 3.4 0 3.5 3.5 05/16/2005 03:50:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 84 4 88 255 3.5 0 3.5 3.5 05/16/2005 04:00:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 79 0 79 255 3.6 0 3.8 3.5 05/16/2005 04:10:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 79 0 79 255 3.7 0 3.8 3.5 05/16/2005 04:20:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 56 9 79 255 3.9 0 4 3.8 05/16/2005 04:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 28 52 255 4 0 4.3 4 05/16/2005 04:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 16 71 255 4.1 0 4.3 4 05/16/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 255 255 4.3 0 4.5 4.3 05/16/2005 05:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 113 11 127 255 4.5 0 4.8 4.3 05/16/2005 05:10:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 118 3 124 255 4.6 0 5 4.5 05/16/2005 05:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 113 5 104 255 4.9 0 5 4.8 05/16/2005 05:30:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 108 8 94 255 5.1 0 5.5 5 05/16/2005 05:40:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 93 18 103 255 5.4 0 5.7 5 05/16/2005 05:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 93 9 94 255 5.7 0 6 5.5 05/16/2005 06:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 107 0 107 255 6.1 0 6.2 5.7 05/16/2005 06:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 72 27 49 255 6.3 0.1 6.7 6.2 05/16/2005 06:20:00 1 0.8 2.6 0.4 0.9 0.7 2.6 0.4 0.9 0.7 2.6 0.4 47 17 23 255 6.7 0.1 7.3 6.5 05/16/2005 06:30:00 1.3 0.5 2.3 0.4 1.1 0.6 2.3 0.4 0.9 0.6 2.6 0.4 45 15 35 255 7.1 0 7.3 7 05/16/2005 06:40:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 44 13 48 255 7.3 0 7.5 7 05/16/2005 06:50:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.5 1.9 0.4 59 32 18 255 7.4 0.1 7.5 7.3 05/16/2005 07:00:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.1 0.4 59 19 51 255 7.6 0 7.8 7.5 05/16/2005 07:10:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 82 17 62 255 7.9 0 8 7.8 05/16/2005 07:20:00 0.7 0.5 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.4 2.3 0.4 55 23 51 255 8.2 0 8.5 8 05/16/2005 07:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 81 17 77 255 8.5 0 8.5 8.3 05/16/2005 07:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.4 2.3 0.4 65 26 55 255 8.7 0 9 8.5 05/16/2005 07:50:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 45 26 66 255 9.3 0.2 9.6 8.8 05/16/2005 08:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 79 38 48 255 9.8 0.1 10.1 9.6 05/16/2005 08:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 0.7 0.4 30 16 3 255 10.3 0.1 10.9 10.1 05/16/2005 08:20:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.5 2.6 0.4 58 61 335 255 11.6 0.3 12.2 10.9 05/16/2005 08:30:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 78 79 10 255 11.1 0.1 11.9 10.9 05/16/2005 08:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 16 49 347 255 11.5 0.4 12.5 10.9 05/16/2005 08:50:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.5 0.3 1.9 0.4 131 45 123 255 11 0.2 11.7 10.9 05/16/2005 09:00:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 110 22 127 255 11.5 0.2 11.7 10.9 05/16/2005 09:10:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 1 0.5 1.9 0.4 128 20 95 255 10.4 0.2 10.9 10.1 05/16/2005 09:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 147 17 141 255 10.5 0.1 11.1 10.3 05/16/2005 09:30:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 40 94 306 255 10.9 0.2 11.7 10.6 05/16/2005 09:40:00 1.2 0.7 2.6 0.4 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 317 21 315 255 11.6 0.2 12.2 11.1 05/16/2005 09:50:00 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.9 0.4 300 24 304 255 11.5 0.2 12.2 11.1 05/16/2005 10:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 284 13 298 255 11.7 0.2 12.2 11.1 05/16/2005 10:10:00 1.5 0.6 3.8 0.4 1.4 0.6 3.4 0.4 1.1 0.6 3.8 0.4 261 12 265 255 12.5 0.7 14.4 11.4 05/16/2005 10:20:00 1.6 0.8 3.8 0.4 1.4 0.8 4.2 0.4 1.2 0.8 3 0.4 313 19 295 255 13.3 0.2 14.4 12.7 05/16/2005 10:30:00 0.8 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.4 1.9 0.4 34 49 305 255 12.8 0.4 13.8 11.9 05/16/2005 10:40:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 116 56 62 255 12.7 0.3 13.5 11.9 05/16/2005 10:50:00 1.1 1 4.2 0.4 1 1 3.8 0.4 0.8 0.8 3.4 0.4 263 86 306 255 13.9 0.3 14.9 13.3 05/16/2005 11:00:00 1.9 1 3.8 0.4 1.7 1.1 3.8 0.4 1.6 1 3.4 0.4 283 22 306 255 13.7 0.2 14.6 13.3 05/16/2005 11:10:00 1.8 0.9 3.8 0.4 1.6 0.8 3.4 0.4 1.3 0.8 3.8 0.4 315 17 294 255 13.3 0 13.8 13 05/16/2005 11:20:00 1.1 0.8 3.8 0.4 0.9 0.8 3.8 0.4 0.7 0.5 2.6 0.4 277 49 288 255 14 0.3 14.9 13.3 05/16/2005 11:30:00 1.3 0.7 3.4 0.4 1.2 0.7 3 0.4 0.8 0.6 3.4 0.4 262 58 241 255 14.9 0.1 15.5 14.6 05/16/2005 11:40:00 1.4 0.7 3.4 0.4 1.1 0.7 3 0.4 0.8 0.5 2.6 0.4 42 86 309 255 15.7 0.2 16.3 15.2 05/16/2005 11:50:00 2.5 1 4.9 0.4 2.4 1 4.9 0.4 2.1 1 6.1 0.4 315 39 315 255 15.5 0.1 16 15.2 05/16/2005 12:00:00 2.2 0.9 4.2 0.4 2 0.9 4.2 0.4 1.8 0.9 4.2 0.4 298 29 296 255 15.1 0 15.5 14.9 05/16/2005 12:10:00 1.8 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.5 0.9 3.4 0.4 316 24 9 255 15 0 15.5 14.9 05/16/2005 12:20:00 1.7 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.3 0.8 3 0.4 291 35 247 255 15.2 0 15.5 15.2 05/16/2005 12:30:00 2.9 0.9 4.6 0.7 2.6 1 4.6 0.4 2.4 1 4.6 0.4 332 22 320 255 15.7 0.2 16.3 15.5 05/16/2005 12:40:00 2.2 1 5.3 0.4 1.8 1 4.6 0.4 1.4 1 4.9 0.4 0 35 343 255 16.1 0 16.6 16 05/16/2005 12:50:00 2.5 0.9 4.6 0.4 2.3 0.9 4.6 0.4 1.7 0.8 3.8 0.4 5 23 2 255 16.6 0.1 16.8 16.3 05/16/2005 13:00:00 2.4 1 4.6 0.4 2.1 1 4.6 0.4 1.8 1 4.2 0.4 7 39 338 255 16.8 0.2 17.4 16.6 05/16/2005 13:10:00 0.7 0.6 3 0.4 0.6 0.6 3 0.4 0.6 0.5 2.6 0.4 80 90 338 255 16.1 0.5 17.4 15.5 05/16/2005 13:20:00 2.8 1.2 5.3 0.4 2.4 1.1 4.6 0.4 2.3 1.3 4.9 0.4 319 53 324 255 15.9 0.2 16.6 15.5 05/16/2005 13:30:00 2.1 1.1 4.6 0.4 1.8 1 4.6 0.4 1.6 1.2 4.2 0.4 327 27 309 255 16.4 0.1 17.1 16 05/16/2005 13:40:00 3.3 1 6.1 0.4 3.1 1 6.5 0.4 2.7 1.2 6.5 0.4 319 24 303 255 17 0 17.4 16.8 05/16/2005 13:50:00 2.3 1.1 4.9 0.4 2 1.1 4.6 0.4 1.6 1 4.2 0.4 0 35 359 255 17.1 0.2 17.7 16.8 05/16/2005 14:00:00 3 1 5.3 0.4 2.7 1 4.9 0.4 2.4 1.1 4.6 0.4 327 29 345 255 17 0 17.4 16.8 05/16/2005 14:10:00 2.3 0.8 4.2 0.4 1.9 0.7 3.4 0.4 1.8 0.8 4.2 0.4 336 23 329 255 16.7 0.2 17.4 16.3 05/16/2005 14:20:00 2.1 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.3 0.8 3.8 0.4 347 16 327 255 16.2 0.1 16.8 16.3 05/16/2005 14:30:00 2.2 0.8 3.8 0.4 2 0.9 3.8 0.4 1.5 0.9 3.4 0.4 337 27 359 255 15.8 0.2 16.6 15.5 05/16/2005 14:40:00 2.3 0.6 4.2 0.4 2.2 0.6 4.2 0.4 1.9 0.8 3.4 0.4 288 20 294 255 15 0 15.7 14.9 05/16/2005 14:50:00 1.2 0.8 3 0.4 1 0.8 2.6 0.4 0.9 0.7 2.6 0.4 350 27 350 255 15 0.1 15.5 14.6 05/16/2005 15:00:00 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1 0.7 3 0.4 5 21 1 255 15.2 0 15.7 15.2 05/16/2005 15:10:00 2.6 0.7 4.2 0.7 2.5 0.8 4.2 0.4 1.8 0.9 3.8 0.4 16 15 10 255 15.7 0 16 15.5 05/16/2005 15:20:00 2.3 0.8 4.2 0.4 2.1 0.9 4.6 0.4 1.3 1 3.8 0.4 17 21 12 255 16.7 0.5 17.4 15.7 05/16/2005 15:30:00 1.6 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.1 0.7 3 0.4 36 29 14 255 17.1 0.1 17.4 16.8 05/16/2005 15:40:00 1.5 1.1 3.4 0.4 1.4 1.1 3.4 0.4 1 1 3.8 0.4 309 49 354 255 18 0.4 18.8 17.1 05/16/2005 15:50:00 1.2 0.8 3.4 0.4 1 0.8 3.4 0.4 0.9 0.8 3 0.4 341 38 325 255 18.1 0.1 18.5 17.7 05/16/2005 16:00:00 1.3 0.8 3.4 0.4 1.1 0.8 3.8 0.4 0.8 0.6 2.6 0.4 241 72 204 255 18.1 0 18.8 18 05/16/2005 16:10:00 2.2 0.8 4.6 0.4 2.1 0.9 4.6 0.4 1.6 0.8 4.2 0.4 308 43 331 255 17.9 0 18.5 17.4 05/16/2005 16:20:00 2.1 1 4.2 0.4 1.9 1.1 4.2 0.4 1.4 0.9 3.8 0.4 264 69 253 255 17.8 0.4 18.5 17.1 05/16/2005 16:30:00 1.1 0.6 3 0.4 0.9 0.6 2.6 0.4 0.7 0.5 3 0.4 228 39 255 255 17.1 0 17.4 16.8 05/16/2005 16:40:00 1 0.7 3 0.4 0.9 0.7 3.4 0.4 0.7 0.6 3.4 0.4 331 72 296 255 17.2 0 17.7 16.8 05/16/2005 16:50:00 1.7 1.3 5.3 0.4 1.6 1.4 6.1 0.4 1.5 1.3 6.5 0.4 269 58 291 255 17.1 0 17.4 16.8 05/16/2005 17:00:00 2.4 0.7 4.6 1.1 2.1 0.8 4.6 0.4 1.8 0.8 4.6 0.4 302 26 284 255 16.9 0.2 17.7 16.6 05/16/2005 17:10:00 1.7 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.8 3.4 0.4 286 35 255 255 16.6 0 17.1 16.3 05/16/2005 17:20:00 2.2 1.2 4.9 0.4 2.1 1.2 4.9 0.4 1.5 1.1 4.6 0.4 306 29 306 255 16.4 0.1 16.8 16.3 05/16/2005 17:30:00 1.8 0.9 4.2 0.4 1.6 1 3.8 0.4 1.4 1 3.8 0.4 273 20 270 255 16.2 0 16.8 16 05/16/2005 17:40:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.8 3 0.4 290 24 300 255 15.9 0 16.3 15.7 05/16/2005 17:50:00 2.1 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.4 0.8 3 0.4 306 17 301 255 15.6 0 16 15.5 05/16/2005 18:00:00 1.9 0.9 3.8 0.4 1.7 1 3.8 0.4 1.2 0.9 4.2 0.4 288 22 301 255 15.5 0 15.7 15.5 05/16/2005 18:10:00 2.6 0.7 4.2 0.7 2.5 0.8 3.8 0.7 2 0.9 4.2 0.4 289 13 277 255 15.5 0 15.7 15.5 05/16/2005 18:20:00 2.7 0.7 4.2 0.4 2.5 0.7 3.8 0.7 2.3 0.7 4.2 0.4 293 15 301 255 15.5 0 15.7 15.2 05/16/2005 18:30:00 3 1.1 5.7 0.4 2.8 1.2 5.7 0.4 2.3 1.3 5.7 0.4 296 26 283 255 15.2 0 15.5 15.2 05/16/2005 18:40:00 3.4 0.8 5.3 1.1 3.2 0.9 5.3 0.4 2.8 0.8 4.9 0.4 287 17 293 255 15 0 15.2 14.9 05/16/2005 18:50:00 2.9 0.7 4.9 1.1 2.7 0.8 4.9 0.7 2 0.8 3.8 0.4 288 22 296 255 14.8 0 15.2 14.6 05/16/2005 19:00:00 3.3 1 5.3 0.4 3.2 1 5.3 0.4 2.5 1 5.7 0.4 274 22 312 255 14.7 0.1 15.2 14.6 05/16/2005 19:10:00 2.5 0.9 4.9 0.4 2.2 1.1 4.9 0.4 1.8 1 3.8 0.4 276 22 255 255 14.6 0 15.2 14.4 05/16/2005 19:20:00 3 1 5.3 0.4 2.7 1.1 4.9 0.4 2.1 1.1 5.3 0.4 275 20 282 255 14.5 0.1 14.9 14.4 05/16/2005 19:30:00 2 1 4.2 0.4 1.7 1 4.2 0.4 1.3 1 3.8 0.4 277 19 266 255 14.2 0.2 14.9 13.8 05/16/2005 19:40:00 2.6 1 4.9 0.4 2.4 1.1 4.6 0.4 1.6 1.1 4.6 0.4 270 19 257 255 13.9 0.1 14.6 13.5 05/16/2005 19:50:00 2.6 0.8 4.6 0.4 2.5 0.9 4.6 0.4 1.7 0.8 3.4 0.4 265 19 277 255 13.5 0.1 14.1 13.3 05/16/2005 20:00:00 2.4 0.9 4.9 0.4 2.2 1 4.9 0.4 1.6 1 4.6 0.4 271 16 255 255 13.3 0.2 13.8 12.7 05/16/2005 20:10:00 2.7 0.8 4.9 0.7 2.5 1 4.9 0.4 1.7 1 4.2 0.4 270 20 259 255 12.8 0 13.3 12.5 05/16/2005 20:20:00 2.6 0.9 4.9 0.7 2.4 1 6.1 0.4 1.8 0.9 4.9 0.4 261 17 252 255 12.4 0.1 13 12.2 05/16/2005 20:30:00 2.2 0.8 4.6 0.4 2 1 4.6 0.4 1.4 0.9 3.4 0.4 263 20 257 255 12.3 0 12.7 11.9 05/16/2005 20:40:00 2.3 0.9 4.6 0.4 2.2 1 4.2 0.4 1.5 0.9 3.8 0.4 266 21 279 255 11.8 0 12.5 11.4 05/16/2005 20:50:00 2.6 0.6 4.9 1.1 2.5 0.6 4.6 1.1 1.5 0.7 3.8 0.4 275 17 291 255 11.3 0 11.7 10.9 05/16/2005 21:00:00 2.3 0.7 3.8 0.7 2.1 0.7 4.2 0.4 1.1 0.8 3.8 0.4 273 15 280 255 10.7 0.1 11.1 10.3 05/16/2005 21:10:00 2.1 0.6 4.2 0.4 1.8 0.8 3.8 0.4 1 0.6 2.6 0.4 262 15 273 255 10.2 0 10.6 9.8 05/16/2005 21:20:00 1.9 0.5 3.4 0.4 1.7 0.6 3.4 0.4 0.7 0.4 1.9 0.4 253 11 255 255 9.8 0.1 10.1 9.6 05/16/2005 21:30:00 1.7 0.5 3.4 0.4 1.5 0.6 3 0.4 0.7 0.4 1.9 0.4 261 13 253 255 9.3 0.1 9.6 9 05/16/2005 21:40:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0 0.7 0.4 263 12 266 255 8.7 0.2 9 8.3 05/16/2005 21:50:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 37 102 115 255 8.1 0.1 8.5 7.8 05/16/2005 22:00:00 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.9 0.5 1.9 0.4 89 17 99 255 7.5 0.1 7.8 7.3 05/16/2005 22:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 328 11 340 255 7.3 0 7.3 7.3 05/16/2005 22:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 315 33 294 255 7 0.2 7.3 6.7 05/16/2005 22:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 14 15 255 6.4 0.1 6.7 6.2 05/16/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 6.2 0 6.7 6 05/16/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 23 255 255 6.2 0 6.7 6 05/16/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 255 255 5.9 0.1 6.2 5.7 05/16/2005 23:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 80 49 124 255 5.7 0 6 5.7 05/16/2005 23:20:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 151 2 148 255 5.4 0 5.7 5.2 05/16/2005 23:30:00 1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 1.1 0.4 1.9 0.4 156 6 153 255 5.1 0 5.5 5 05/16/2005 23:40:00 1.3 0.3 1.9 0.4 1.1 0.2 1.9 0.4 1.3 0.3 1.9 0.7 159 4 157 255 4.9 0 5 4.8 05/16/2005 23:50:00 1.9 0.4 2.6 0.7 1.7 0.4 2.6 0.4 1.1 0.6 2.6 0.4 153 7 155 255 4.5 0.1 4.8 4.3 05/17/2005 00:00:00 1.3 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.4 0.2 1.5 0.4 144 6 147 255 4.2 0 4.5 4 05/17/2005 00:10:00 0.8 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 140 0 140 255 4 0 4.3 4 05/17/2005 00:20:00 2.1 0.5 3.4 1.1 2 0.6 3 1.1 1.1 0.7 3 0.4 141 4 138 255 3.9 0 4 3.5 05/17/2005 00:30:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.5 0.4 3.4 1.5 139 4 140 255 3.8 0 4.3 3.5 05/17/2005 00:40:00 3.5 0.3 4.2 3 3.5 0.3 4.2 2.6 2.9 0.4 3.4 1.5 149 4 144 255 4.2 0 4.3 4 05/17/2005 00:50:00 3.3 0.2 4.2 3 3.3 0.2 3.8 2.6 2.3 0.4 3.4 1.5 155 2 149 255 4.3 0 4.5 4 05/17/2005 01:00:00 3.4 0.3 3.8 1.9 3.4 0.3 3.8 2.3 2 0.4 3 0.7 157 4 156 255 4.5 0 4.5 4.5 05/17/2005 01:10:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 1.8 0.5 2.6 0.4 158 3 158 255 4.5 0 4.5 4.5 05/17/2005 01:20:00 3.1 0.4 4.2 1.9 3 0.5 3.8 1.9 1.5 0.5 2.6 0.4 156 4 155 255 4.5 0 4.5 4.3 05/17/2005 01:30:00 3.4 0.3 3.8 2.6 3.3 0.3 3.8 2.3 1.9 0.4 2.6 0.4 155 4 151 255 4.3 0 4.5 4.3 05/17/2005 01:40:00 3 0.5 3.8 1.5 2.9 0.5 3.8 1.5 1.7 0.7 3.4 0.4 155 5 148 255 4.2 0 4.3 4.3 05/17/2005 01:50:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 2.2 0.5 3.4 0.7 151 4 148 255 4.1 0 4.3 4 05/17/2005 02:00:00 3.4 0.5 4.2 1.5 3.4 0.5 4.2 1.5 2.2 0.6 3.4 0.4 146 6 145 255 4.1 0 4.3 4 05/17/2005 02:10:00 0.9 0.5 3 0.4 0.8 0.5 2.6 0.4 0.7 0.5 1.9 0.4 61 72 137 255 3.7 0.2 4 3.5 05/17/2005 02:20:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 4 3 5 255 3.2 0 3.5 3 05/17/2005 02:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 43 38 129 255 2.9 0 3.3 2.8 05/17/2005 02:40:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 120 10 108 255 2.9 0 3.3 2.8 05/17/2005 02:50:00 1.8 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1 0.5 2.3 0.4 125 11 110 255 2.9 0 3 2.8 05/17/2005 03:00:00 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.5 0.4 140 12 121 255 3 0 3.3 2.8 05/17/2005 03:10:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 0.9 0.4 1.9 0.4 126 9 118 255 3 0 3.3 2.8 05/17/2005 03:20:00 2.2 0.5 3.4 1.1 2 0.6 3.8 0.7 0.9 0.5 3 0.4 115 11 108 255 3 0 3.3 2.8 05/17/2005 03:30:00 2.4 0.5 3.8 1.1 2.3 0.6 3.8 0.7 1.1 0.5 2.6 0.4 117 10 121 255 3 0 3.3 2.8 05/17/2005 03:40:00 1.6 0.5 3 0.4 1.4 0.6 3 0.4 0.7 0.4 1.5 0.4 127 10 126 255 2.9 0 3.3 2.8 05/17/2005 03:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.1 0.4 130 5 124 255 2.9 0 3.5 2.8 05/17/2005 04:00:00 0.7 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 123 9 122 255 2.9 0 3.3 2.8 05/17/2005 04:10:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 0.7 0.3 1.9 0.4 145 12 163 255 3 0 3.5 2.8 05/17/2005 04:20:00 2 0.3 2.6 0.7 1.9 0.3 2.3 0.7 1 0.4 1.9 0.4 168 9 168 255 2.9 0 3.5 2.8 05/17/2005 04:30:00 2.7 0.5 3.8 1.5 2.7 0.5 4.2 1.1 1.6 0.7 3.4 0.4 144 12 140 255 2.8 0 3.3 2.6 05/17/2005 04:40:00 2.3 0.4 3.4 1.1 2.2 0.5 3.4 1.1 1.7 0.6 3 0.4 129 10 116 255 2.6 0 3 2.6 05/17/2005 04:50:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.1 2 0.6 3.4 0.4 128 12 124 255 3.2 0.3 4 2.6 05/17/2005 05:00:00 2.4 0.5 3.4 1.1 2.4 0.6 3.8 0.7 1.8 0.6 3.4 0.4 128 10 122 255 4 0.1 4.5 3.8 05/17/2005 05:10:00 1.7 0.5 3 0.4 1.6 0.6 3 0.4 1.1 0.5 2.3 0.4 132 12 113 255 4.5 0 5 4.3 05/17/2005 05:20:00 1.6 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.4 2.3 0.4 124 9 118 255 4.5 0 4.8 4.3 05/17/2005 05:30:00 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.3 0.4 127 13 133 255 4.4 0 4.8 4.3 05/17/2005 05:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 134 12 137 255 4.6 0 4.8 4.3 05/17/2005 05:50:00 0.8 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.9 0.4 137 11 122 255 5 0.1 5.5 4.8 05/17/2005 06:00:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 1 0.5 2.3 0.4 132 10 126 255 5.2 0 5.7 5 05/17/2005 06:10:00 1.9 0.4 3 0.7 1.8 0.5 2.6 0.4 1.2 0.6 2.6 0.4 137 11 129 255 5.6 0.1 5.7 5.5 05/17/2005 06:20:00 2.1 0.5 3.8 0.4 2 0.6 3.4 0.4 1.6 0.6 2.6 0.4 132 12 118 255 6 0 6.2 5.7 05/17/2005 06:30:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 126 15 133 255 6.3 0.1 6.7 6.2 05/17/2005 06:40:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 126 13 128 255 6.7 0 7 6.5 05/17/2005 06:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 110 10 127 255 7.1 0 7.3 7 05/17/2005 07:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 112 1 113 255 7.6 0.1 7.8 7.3 05/17/2005 07:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 113 5 124 255 8 0 8.3 7.8 05/17/2005 07:20:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 125 22 116 255 8.3 0 8.5 8.3 05/17/2005 07:30:00 1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 0.9 0.6 2.6 0.4 109 14 122 255 8.7 0.1 9 8.5 05/17/2005 07:40:00 1.6 0.6 3 0.4 1.4 0.7 2.6 0.4 1.4 0.6 2.6 0.4 103 9 94 255 9.1 0 9.3 9 05/17/2005 07:50:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 76 11 80 255 9.6 0.1 9.8 9.3 05/17/2005 08:00:00 0.7 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 65 18 83 255 10 0 10.3 9.8 05/17/2005 08:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 40 32 37 255 10.4 0 10.9 10.3 05/17/2005 08:20:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 7 29 22 255 10.7 0 10.9 10.6 05/17/2005 08:30:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 354 19 343 255 11 0 11.1 10.6 05/17/2005 08:40:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 349 22 331 255 11.3 0 11.9 11.1 05/17/2005 08:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 27 15 20 255 11.5 0 11.9 11.4 05/17/2005 09:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 23 14 32 255 11.8 0.1 12.2 11.7 05/17/2005 09:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.5 0.4 0.4 0.2 1.5 0.4 53 19 49 255 12 0.1 12.5 11.7 05/17/2005 09:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 29 17 27 255 11.9 0.1 12.2 11.7 05/17/2005 09:30:00 0.6 0.4 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.9 0.4 4 17 0 255 11.9 0.2 12.5 11.7 05/17/2005 09:40:00 1.6 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.2 0.5 2.6 0.4 25 11 23 255 12.1 0 12.5 11.9 05/17/2005 09:50:00 1.4 0.3 2.3 0.4 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 6 11 355 255 12.1 0.1 12.7 11.9 05/17/2005 10:00:00 1.1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.4 1.9 0.4 12 15 15 255 12.5 0.2 13 12.2 05/17/2005 10:10:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 9 19 351 255 12.8 0 13.3 12.5 05/17/2005 10:20:00 1 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.6 0.4 1.9 0.4 6 20 33 255 12.7 0 13 12.5 05/17/2005 10:30:00 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 15 10 22 255 12.7 0 13 12.5 05/17/2005 10:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 33 26 40 255 12.8 0 13.3 12.7 05/17/2005 10:50:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 42 16 37 255 12.9 0 13.3 12.7 05/17/2005 11:00:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 42 32 53 255 13.3 0 13.8 13 05/17/2005 11:10:00 2.2 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.7 0.7 3.4 0.4 42 13 47 255 13.3 0 13.8 13 05/17/2005 11:20:00 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1 0.8 3.8 0.4 43 18 19 255 13.3 0 13.8 13 05/17/2005 11:30:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.6 2.3 0.4 56 15 39 255 13.1 0.2 13.8 12.7 05/17/2005 11:40:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 67 23 94 255 13.2 0 13.8 12.7 05/17/2005 11:50:00 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.9 0.4 48 47 43 255 14.6 0.7 16 13.3 05/17/2005 12:00:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.5 2.6 0.4 8 33 49 255 16.2 0.3 16.8 15.7 05/17/2005 12:10:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.5 2.6 0.4 28 56 34 255 17.1 0.2 17.4 16.8 05/17/2005 12:20:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 291 32 283 255 16.4 0.1 16.8 16 05/17/2005 12:30:00 1 0.8 3.8 0.4 1 0.9 3.4 0.4 0.9 0.8 3.4 0.4 248 58 190 255 16.8 0 17.1 16.6 05/17/2005 12:40:00 1.6 0.6 3.4 0.4 1.5 0.7 3 0.4 1.1 0.7 3 0.4 188 36 240 255 16 0.2 16.6 15.7 05/17/2005 12:50:00 1.9 1 4.9 0.4 1.8 1 4.9 0.4 1.3 1 4.6 0.4 251 51 239 255 16.4 0.3 17.4 16.3 05/17/2005 13:00:00 1 0.7 3.4 0.4 0.9 0.7 3 0.4 0.6 0.4 2.3 0.4 244 94 209 255 17.1 0.3 17.7 16.3 05/17/2005 13:10:00 2.4 1 4.6 0.4 2.4 1.1 4.6 0.4 2 1 4.6 0.4 161 23 188 255 16 0.3 16.8 15.7 05/17/2005 13:20:00 2.1 1 4.6 0.4 2.2 1 4.6 0.4 2 0.9 4.2 0.4 185 29 189 255 17.1 0.4 18 16.6 05/17/2005 13:30:00 1.7 1 4.6 0.4 1.6 1.1 4.2 0.4 1.3 1.1 4.2 0.4 241 53 334 255 18.1 0.2 18.5 17.7 05/17/2005 13:40:00 2.8 1.3 6.1 0.4 2.7 1.2 5.3 0.4 2.1 1.1 4.6 0.4 269 56 284 255 18.3 0.5 19.4 17.7 05/17/2005 13:50:00 3.8 1.2 6.8 0.7 3.6 1.3 6.8 0.4 2.4 1.3 5.7 0.4 290 35 319 255 19.6 0.2 20.3 19.1 05/17/2005 14:00:00 4.2 1.1 7.2 1.1 4.1 1.2 7.2 0.7 3.5 1.2 7.6 0.7 296 21 288 255 19.4 0.3 20.5 18.8 05/17/2005 14:10:00 4.4 1 6.5 1.9 4.3 1 6.8 1.9 3.5 1.3 6.8 0.4 300 20 297 255 18.9 0.2 19.4 18.5 05/17/2005 14:20:00 4.1 1.3 6.8 0.7 4 1.4 7.2 0.7 3.4 1.5 7.6 0.4 295 18 304 255 17.5 0.5 18.5 16.6 05/17/2005 14:30:00 3.6 1 5.7 1.1 3.4 1 5.7 0.7 2.6 1.1 5.7 0.4 300 21 283 255 15.8 0.3 16.8 15.5 05/17/2005 14:40:00 3 0.9 4.9 0.7 2.9 1 4.9 0.4 2.3 0.9 4.6 0.4 301 19 318 255 16.1 0.4 17.1 15.5 05/17/2005 14:50:00 3 1 5.3 0.4 2.9 1 5.3 0.4 2.4 1.2 5.3 0.4 300 21 306 255 17.4 0.5 18.5 16.8 05/17/2005 15:00:00 2.4 1.1 5.3 0.4 2.3 1.2 5.3 0.4 1.5 1 4.2 0.4 281 24 289 255 16.8 0.5 18.2 16.3 05/17/2005 15:10:00 2.9 1.5 6.1 0.4 2.7 1.6 6.1 0.4 2.4 1.7 6.8 0.4 283 29 278 255 17.9 0.5 18.8 16.8 05/17/2005 15:20:00 2.8 1.2 6.1 0.4 2.7 1.2 5.3 0.4 2.2 1.1 5.3 0.4 273 32 277 255 17.2 0 18 16.8 05/17/2005 15:30:00 3.5 1 5.7 0.7 3.3 1.1 5.7 0.4 2.7 1.2 4.9 0.4 297 23 286 255 16.1 0.3 17.1 15.7 05/17/2005 15:40:00 3.6 1 5.7 0.7 3.5 1.1 5.7 0.4 2.6 1.1 5.3 0.4 298 18 282 255 15.6 0 16 15.5 05/17/2005 15:50:00 2.8 1 5.3 0.4 2.6 1.1 5.3 0.4 2.1 1.3 4.9 0.4 280 22 291 255 16.3 0.1 16.8 15.7 05/17/2005 16:00:00 2.3 1 4.6 0.4 2.2 1.1 4.6 0.4 1.7 1 3.8 0.4 266 22 255 255 16.1 0 16.6 15.7 05/17/2005 16:10:00 2.2 0.5 3.4 0.7 1.9 0.5 3.4 0.4 1.6 0.7 3 0.4 289 16 282 255 15.7 0.2 16.3 15.5 05/17/2005 16:20:00 1.7 1 4.6 0.4 1.5 1 4.2 0.4 1.1 0.9 3.4 0.4 270 30 283 255 16.8 0.5 17.4 16.3 05/17/2005 16:30:00 1.3 1 4.2 0.4 1.1 1 3.8 0.4 0.9 0.7 3.4 0.4 287 76 264 255 17.3 0.1 17.7 17.1 05/17/2005 16:40:00 1.6 1 4.2 0.4 1.3 0.9 4.2 0.4 1.2 0.9 3.4 0.4 270 56 253 255 17.6 0 18 17.1 05/17/2005 16:50:00 1.9 0.7 3.8 0.4 1.6 0.8 3.4 0.4 1.4 0.7 3.4 0.4 303 23 327 255 17.7 0 18.2 17.4 05/17/2005 17:00:00 2.5 1 6.1 0.4 2.2 1.1 5.7 0.4 1.7 1.1 4.6 0.4 329 26 331 255 17.6 0.2 18.2 17.1 05/17/2005 17:10:00 2 0.9 4.6 0.4 1.8 0.9 4.2 0.4 1.5 1 4.2 0.4 336 49 304 255 17.5 0.1 17.7 17.1 05/17/2005 17:20:00 2.6 1.1 5.7 0.4 2.4 1.1 4.9 0.4 2 1.3 5.3 0.4 21 64 334 255 17.8 0 18.2 17.1 05/17/2005 17:30:00 2.5 1.1 5.3 0.4 2.2 1.2 5.3 0.4 1.6 1 4.9 0.4 347 35 345 255 17.6 0 18.2 17.4 05/17/2005 17:40:00 4.9 1.6 7.2 1.1 4.8 1.6 7.2 0.7 3.9 1.7 6.8 0.4 16 18 31 255 17.1 0.4 18.2 16.6 05/17/2005 17:50:00 5.5 1.2 8 3 5.5 1.2 8 3 3.8 1.4 7.2 1.1 9 13 20 255 16.1 0 16.6 15.7 05/17/2005 18:00:00 5.6 1.3 8.4 2.3 5.5 1.3 8.4 2.3 4.2 1.5 7.6 0.4 12 14 11 255 15.5 0 16 15.5 05/17/2005 18:10:00 4.1 1 6.8 1.9 3.9 1.1 6.8 1.5 2.8 1.1 5.7 0.4 14 21 12 255 15.1 0 15.5 15.2 05/17/2005 18:20:00 4.1 1.1 6.8 1.1 4 1.1 6.8 1.5 2.9 1.2 6.1 0.4 23 15 30 255 14.8 0.1 15.2 14.6 05/17/2005 18:30:00 4.1 0.7 5.7 1.9 4 0.8 5.7 1.9 2.8 1 5.7 0.4 16 13 22 255 14.5 0 14.9 14.4 05/17/2005 18:40:00 4.2 0.9 6.8 1.5 4.1 0.9 7.2 1.5 2.5 1 4.9 0.4 10 12 14 255 14.4 0.1 14.9 14.1 05/17/2005 18:50:00 4.2 1 6.8 1.9 4.1 1 6.8 1.5 3 1.1 6.1 0.4 17 14 19 255 13.9 0.1 14.6 13.5 05/17/2005 19:00:00 2.6 0.9 4.9 0.7 2.3 1 4.9 0.4 1.4 0.9 4.2 0.4 353 19 26 255 13.3 0.3 13.8 12.7 05/17/2005 19:10:00 1.6 1.2 4.9 0.4 1.3 1.2 4.9 0.4 1 0.9 4.2 0.4 316 35 356 255 12.8 0 13.3 12.5 05/17/2005 19:20:00 1.8 0.6 3 0.4 1.4 0.7 3 0.4 0.8 0.6 2.6 0.4 333 24 331 255 12.3 0.3 13 11.7 05/17/2005 19:30:00 3 1.2 5.7 0.4 2.8 1.3 5.7 0.4 2.1 1.3 5.3 0.4 25 17 51 255 11.9 0.1 12.5 11.7 05/17/2005 19:40:00 2.7 1.2 5.7 0.4 2.6 1.3 5.7 0.4 1.6 1.2 4.9 0.4 20 18 30 255 12.6 0.1 13.3 12.2 05/17/2005 19:50:00 2.2 1 4.9 0.4 1.9 1 4.6 0.4 1.3 0.8 3.8 0.4 30 15 25 255 12 0.2 12.7 11.7 05/17/2005 20:00:00 1.6 1 3.4 0.4 1.4 1 3.4 0.4 0.8 0.6 2.6 0.4 30 13 6 255 11.1 0.2 11.7 10.6 05/17/2005 20:10:00 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.5 0.3 1.5 0.4 57 20 45 255 10.6 0 11.1 10.3 05/17/2005 20:20:00 1.8 0.4 2.6 1.1 1.6 0.4 2.3 0.4 0.8 0.5 1.9 0.4 18 10 6 255 10.2 0 10.6 9.8 05/17/2005 20:30:00 1.7 0.6 3 0.4 1.4 0.7 3.4 0.4 0.5 0.3 1.5 0.4 22 11 43 255 9.6 0.1 9.8 9.3 05/17/2005 20:40:00 1.9 0.5 3 0.7 1.6 0.5 3 0.4 0.7 0.5 2.6 0.4 24 9 25 255 9.3 0 9.3 9 05/17/2005 20:50:00 1.9 0.4 3 0.7 1.7 0.5 2.6 0.4 0.7 0.4 2.3 0.4 17 14 14 255 9.2 0 9.3 9 05/17/2005 21:00:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.7 0.5 0.2 1.1 0.4 10 6 2 255 9.2 0 9.6 9 05/17/2005 21:10:00 2 0.5 3.4 1.1 1.8 0.6 3 0.7 0.9 0.6 2.6 0.4 17 6 14 255 9.4 0 9.6 9.3 05/17/2005 21:20:00 2.5 0.5 4.2 1.1 2.2 0.5 4.2 1.1 1.3 0.6 3 0.4 356 12 2 255 9.5 0 9.8 9.6 05/17/2005 21:30:00 2.2 0.6 4.2 0.7 1.7 0.7 4.2 0.4 0.9 0.5 2.3 0.4 347 10 335 255 9.5 0 9.6 9.3 05/17/2005 21:40:00 2.5 0.5 3.4 1.1 2.3 0.6 3.4 0.4 1 0.6 2.6 0.4 357 10 17 255 9.4 0 9.6 9.3 05/17/2005 21:50:00 2.4 0.4 3.4 1.1 2.2 0.5 3 0.7 0.8 0.5 2.3 0.4 356 9 0 255 9 0 9.3 8.8 05/17/2005 22:00:00 2.7 0.4 3.8 1.5 2.5 0.4 3.8 1.5 0.9 0.6 2.6 0.4 353 9 345 255 8.5 0.1 9 8.3 05/17/2005 22:10:00 2.4 0.5 3.8 1.1 1.9 0.6 3.8 0.4 1 0.6 2.6 0.4 326 12 340 255 8.1 0.1 8.5 7.8 05/17/2005 22:20:00 1.7 0.6 3.4 0.4 1.1 0.7 3 0.4 0.5 0.4 3 0.4 333 11 320 255 7.8 0 8 7.8 05/17/2005 22:30:00 1.6 0.4 2.6 0.7 1.2 0.5 2.6 0.4 0.4 0.2 1.5 0.4 2 11 351 255 7.6 0 7.8 7.5 05/17/2005 22:40:00 2.4 0.6 3.8 0.7 2.2 0.7 3.8 0.4 0.8 0.6 2.6 0.4 15 13 10 255 7.4 0 7.8 7.3 05/17/2005 22:50:00 2.1 0.3 2.6 1.1 1.8 0.3 2.6 1.1 0.7 0.4 1.5 0.4 12 15 351 255 7.1 0 7.3 7 05/17/2005 23:00:00 1.8 0.4 2.6 0.7 1.3 0.4 2.3 0.4 0.6 0.3 1.9 0.4 2 22 339 255 6.6 0.2 7 6.2 05/17/2005 23:10:00 1.8 0.5 3 0.7 1.4 0.5 3 0.4 0.5 0.3 1.9 0.4 20 26 338 255 6.2 0 6.2 6 05/17/2005 23:20:00 1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0 0.7 0.4 31 4 42 255 5.9 0 6.2 5.7 05/17/2005 23:30:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 29 0 30 255 5.8 0.1 6 5.7 05/17/2005 23:40:00 2.1 1.1 3.8 0.4 1.9 1.2 3.8 0.4 1.2 0.8 3 0.4 81 28 87 255 5.5 0 5.7 5.2 05/17/2005 23:50:00 2.9 0.7 4.2 1.1 2.7 0.8 4.2 0.7 1.5 0.8 3.4 0.4 97 10 100 255 5.1 0 5.2 4.8 05/18/2005 00:00:00 1.8 0.4 2.6 0.4 1.6 0.5 2.6 0.4 1.2 0.7 3 0.4 125 14 136 255 4.9 0 5 4.8 05/18/2005 00:10:00 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1 0.6 3 0.4 121 15 108 255 4.8 0 5 4.8 05/18/2005 00:20:00 2.7 0.5 3.4 1.5 2.5 0.5 3.4 1.1 1.4 0.6 2.6 0.4 106 7 105 255 4.6 0 4.8 4.5 05/18/2005 00:30:00 1.9 0.3 3 1.1 1.6 0.4 2.6 0.7 0.6 0.4 1.9 0.4 97 12 96 255 4.3 0.1 4.5 4.3 05/18/2005 00:40:00 2 0.3 2.6 1.1 1.7 0.3 2.6 0.7 0.6 0.4 1.9 0.4 79 6 87 255 4.1 0 4.3 4 05/18/2005 00:50:00 2 0.3 2.6 1.1 1.7 0.3 2.3 0.7 0.7 0.3 1.5 0.4 95 13 77 255 4 0 4.3 4 05/18/2005 01:00:00 2 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1 0.4 1.9 0.4 113 11 113 255 4 0 4 3.8 05/18/2005 01:10:00 2.5 0.5 3.8 1.5 2.4 0.5 3.4 1.1 1.3 0.5 2.3 0.4 107 9 100 255 3.7 0 3.8 3.5 05/18/2005 01:20:00 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.5 1.3 0.5 2.3 0.4 103 6 104 255 3.7 0 3.8 3.5 05/18/2005 01:30:00 1.9 0.5 3.4 0.7 1.6 0.6 3 0.4 0.7 0.5 2.3 0.4 113 14 113 255 3.7 0 3.8 3.5 05/18/2005 01:40:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1.1 0.5 2.3 0.4 152 11 143 255 3.8 0 4 3.8 05/18/2005 01:50:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 137 9 144 255 3.8 0 4 3.5 05/18/2005 02:00:00 1.7 0.5 3 0.7 1.4 0.5 2.6 0.4 0.7 0.3 1.9 0.4 119 13 105 255 3.8 0 4 3.8 05/18/2005 02:10:00 1.9 0.6 3 0.4 1.7 0.8 3.4 0.4 1.3 0.7 3 0.4 125 15 136 255 3.6 0 3.8 3.5 05/18/2005 02:20:00 2.4 0.5 3.4 1.1 2.2 0.5 3 0.7 1 0.6 2.3 0.4 118 11 144 255 3.4 0 3.5 3.3 05/18/2005 02:30:00 2.2 0.4 3.4 1.1 2 0.5 3.4 0.7 1.1 0.6 2.6 0.4 117 9 122 255 3 0 3.3 2.8 05/18/2005 02:40:00 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.4 1.2 0.5 2.6 0.4 122 11 102 255 2.8 0 3 2.6 05/18/2005 02:50:00 2.1 0.5 3.4 1.1 1.9 0.6 3.4 0.7 0.7 0.4 1.9 0.4 117 12 103 255 2.9 0 2.8 2.6 05/18/2005 03:00:00 2.3 0.5 3.4 1.1 2.1 0.5 3 0.7 1 0.6 2.3 0.4 106 9 106 255 2.7 0 2.8 2.3 05/18/2005 03:10:00 1.7 0.4 2.6 0.7 1.4 0.5 2.3 0.4 0.5 0.3 1.5 0.4 115 11 117 255 2.4 0 2.8 2.3 05/18/2005 03:20:00 1.7 0.5 3 0.7 1.5 0.6 3 0.4 0.6 0.3 1.9 0.4 128 13 116 255 2.3 0 2.8 2.3 05/18/2005 03:30:00 1.4 0.4 2.6 0.4 1.4 0.5 2.6 0.4 0.8 0.4 1.9 0.4 166 16 163 255 2.1 0.1 2.6 1.8 05/18/2005 03:40:00 2.1 0.5 3.4 1.1 2.4 0.4 3.4 1.1 1.4 0.5 3 0.4 173 9 166 255 2.3 0 2.8 1.8 05/18/2005 03:50:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 1.6 0.5 3 0.4 148 7 148 255 1.8 0.2 2.6 1.4 05/18/2005 04:00:00 3.5 0.4 4.6 2.3 3.5 0.4 4.2 2.3 2.3 0.5 3.4 0.4 144 6 147 255 1.5 0 1.8 1.4 05/18/2005 04:10:00 3.2 0.6 4.6 1.5 3.2 0.6 4.6 1.5 2.2 0.6 3.8 0.4 136 8 143 255 1.7 0 1.8 1.6 05/18/2005 04:20:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.1 1.9 0.5 3.4 0.4 134 12 148 255 1.6 0 1.8 1.6 05/18/2005 04:30:00 2.6 0.6 4.2 1.1 2.5 0.7 4.6 1.1 1.5 0.7 3.4 0.4 129 11 118 255 1.7 0 1.8 1.6 05/18/2005 04:40:00 2.4 1 4.6 0.4 2.3 1 4.6 0.4 1.1 0.9 3.8 0.4 132 12 102 255 1.8 0 2.1 1.6 05/18/2005 04:50:00 0.9 0.5 2.3 0.4 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 124 17 117 255 2.1 0.1 2.6 1.8 05/18/2005 05:00:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 0.5 0.2 1.5 0.4 112 11 112 255 2.3 0 2.6 2.3 05/18/2005 05:10:00 1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.4 0 0.7 0.4 105 11 100 255 2.3 0 2.8 2.3 05/18/2005 05:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 125 15 101 255 2.6 0 2.8 2.3 05/18/2005 05:30:00 1.3 0.7 3.4 0.4 1.2 0.8 3.4 0.4 0.8 0.6 3 0.4 118 17 129 255 3 0.1 3.5 2.6 05/18/2005 05:40:00 1.5 0.6 3 0.4 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 134 11 127 255 3.6 0.2 4.5 3.3 05/18/2005 05:50:00 1.7 0.5 3 0.4 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 132 12 140 255 5.4 0.5 6.2 4.5 05/18/2005 06:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 126 14 121 255 6.8 0.3 7.3 6.2 05/18/2005 06:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 115 14 136 255 7.6 0.2 8.3 7.3 05/18/2005 06:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.5 0.4 101 26 109 255 8.5 0.1 8.8 8.3 05/18/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 111 0 255 255 9.2 0.3 9.8 8.8 05/18/2005 06:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 120 18 136 255 10 0.2 10.3 9.8 05/18/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 153 12 152 255 10.4 0 10.6 10.3 05/18/2005 07:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 170 10 161 255 10.5 0.1 11.1 10.3 05/18/2005 07:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 183 35 173 255 11.4 0.2 11.9 10.9 05/18/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 108 26 143 255 11.6 0.2 12.2 11.4 05/18/2005 07:30:00 0.8 0.6 3 0.4 0.7 0.6 3 0.4 0.5 0.4 2.3 0.4 195 38 206 255 12.3 0.3 12.7 11.7 05/18/2005 07:40:00 0.8 0.6 3 0.4 0.7 0.6 3 0.4 0.7 0.5 2.3 0.4 261 90 204 255 12.8 0 13.3 12.5 05/18/2005 07:50:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 237 39 283 255 12.9 0.1 13.3 12.5 05/18/2005 08:00:00 1.1 0.7 3 0.4 1 0.7 2.6 0.4 0.7 0.6 2.6 0.4 236 20 268 255 13.2 0 13.8 13 05/18/2005 08:10:00 1.1 0.7 3 0.4 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 271 26 253 255 13.3 0.2 13.8 13 05/18/2005 08:20:00 1 0.9 3.8 0.4 1 0.9 3.4 0.4 0.9 0.8 3 0.4 237 69 263 255 13.7 0.2 14.1 13.3 05/18/2005 08:30:00 0.9 0.7 3.4 0.4 0.9 0.7 3.4 0.4 0.7 0.5 2.6 0.4 299 56 256 255 14.1 0.1 14.6 13.8 05/18/2005 08:40:00 1 0.8 3.4 0.4 0.9 0.7 3 0.4 0.7 0.6 2.6 0.4 306 38 292 255 14 0 14.4 13.8 05/18/2005 08:50:00 1.8 1 4.2 0.4 1.7 1 3.8 0.4 1.3 1 4.6 0.4 288 43 332 255 14.3 0.1 14.6 13.8 05/18/2005 09:00:00 1.7 1.1 4.2 0.4 1.6 1.2 4.2 0.4 1.2 1.1 3.8 0.4 262 53 255 255 14.2 0.2 14.6 13.8 05/18/2005 09:10:00 1.3 0.7 3 0.4 1.3 0.8 3.8 0.4 0.9 0.7 2.6 0.4 217 61 189 255 14.6 0.1 14.9 14.1 05/18/2005 09:20:00 1.5 0.7 3 0.4 1.5 0.7 3 0.4 1.2 0.6 3.4 0.4 80 90 181 255 14.5 0 14.9 14.4 05/18/2005 09:30:00 1.2 0.8 3.8 0.4 1.1 0.8 3.4 0.4 0.9 0.7 2.6 0.4 292 64 274 255 15 0 15.5 14.9 05/18/2005 09:40:00 1.1 0.6 3 0.4 1 0.7 3.4 0.4 0.8 0.6 3 0.4 256 43 226 255 14.8 0.3 15.5 14.4 05/18/2005 09:50:00 0.6 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 202 53 302 255 14.4 0.3 15.5 14.1 05/18/2005 10:00:00 1.9 1.2 4.9 0.4 1.9 1.2 4.9 0.4 1.6 1.2 4.9 0.4 263 45 253 255 15.5 0.1 16 15.2 05/18/2005 10:10:00 2.9 0.8 5.3 1.1 2.8 0.8 4.9 1.1 2.3 1 5.7 0.4 273 26 266 255 15.6 0.2 16.3 15.2 05/18/2005 10:20:00 3.2 1 5.3 0.4 3.1 1 5.3 0.4 2.5 1 4.9 0.4 296 24 300 255 14.4 0.3 15.2 14.1 05/18/2005 10:30:00 2.5 1 5.3 0.4 2.3 1.1 5.3 0.4 2 1.2 4.9 0.4 276 30 251 255 14.6 0.1 15.2 14.4 05/18/2005 10:40:00 2.8 1 5.3 0.7 2.6 1 4.9 0.4 2.1 1.1 4.9 0.4 277 39 255 255 14.9 0 15.2 14.6 05/18/2005 10:50:00 3 1.2 6.5 0.4 2.8 1.3 5.7 0.4 2.3 1.2 4.9 0.4 305 32 331 255 15.7 0.4 16.3 15.2 05/18/2005 11:00:00 2.3 1 4.6 0.4 2.2 1.1 4.9 0.4 1.8 0.9 4.6 0.4 253 51 233 255 16.4 0 16.8 16.3 05/18/2005 11:10:00 2.3 1 4.9 0.4 2 1.1 4.9 0.4 1.9 1 4.2 0.4 300 24 284 255 16.3 0.2 16.8 16 05/18/2005 11:20:00 1.4 0.8 3.4 0.4 1.2 0.8 3 0.4 1 0.6 2.6 0.4 12 69 337 255 16.3 0.4 17.1 15.7 05/18/2005 11:30:00 2.5 0.9 4.2 0.4 2.2 1 4.6 0.4 1.9 0.9 3.8 0.4 342 36 331 255 17.3 0 17.7 16.8 05/18/2005 11:40:00 1.7 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.2 0.8 3.8 0.4 323 36 301 255 17.7 0.4 18.5 16.8 05/18/2005 11:50:00 2.9 1.4 7.2 0.4 2.7 1.5 7.2 0.4 2.2 1.3 6.8 0.4 323 36 299 255 18.2 0 18.5 18 05/18/2005 12:00:00 2.2 1.1 4.6 0.4 1.9 1.1 4.6 0.4 1.7 1 4.2 0.4 306 64 259 255 18.4 0.4 19.1 17.7 05/18/2005 12:10:00 1.4 0.9 3.8 0.4 1.3 0.9 3.4 0.4 1.2 0.8 3.4 0.4 305 47 262 255 17.6 0.8 19.1 16.6 05/18/2005 12:20:00 1.1 0.8 3.8 0.4 1 0.9 3.8 0.4 0.8 0.8 3.8 0.4 248 98 295 255 17.7 0.4 18.2 16.8 05/18/2005 12:30:00 2.4 0.9 4.6 0.4 2.3 0.9 4.6 0.4 1.8 1 3.8 0.4 294 38 307 255 18.5 0.3 19.1 17.7 05/18/2005 12:40:00 1.8 0.9 4.6 0.4 1.7 0.9 3.8 0.4 1.5 0.8 3.4 0.4 250 66 293 255 18.3 0.2 18.5 17.7 05/18/2005 12:50:00 2.7 1.1 5.7 0.4 2.5 1.1 5.7 0.4 2.3 1 4.9 0.4 295 56 311 255 18.3 0.2 18.5 17.7 05/18/2005 13:00:00 2.3 0.8 4.9 0.4 2 0.9 4.9 0.4 1.9 1.1 4.6 0.4 275 41 254 255 19 0.1 19.4 18.5 05/18/2005 13:10:00 1.7 0.8 4.2 0.4 1.6 0.9 3.8 0.4 1.4 0.7 3 0.4 225 79 213 255 18.8 0 19.1 18.5 05/18/2005 13:20:00 2.4 0.9 4.6 0.4 2.3 0.9 4.2 0.4 2.1 0.7 4.2 0.4 214 38 211 255 19.1 0 19.4 18.5 05/18/2005 13:30:00 1.3 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.3 0.6 3 0.4 125 72 241 255 18.7 0.1 19.1 18.2 05/18/2005 13:40:00 1.9 1.2 6.1 0.4 1.8 1.3 5.7 0.4 1.7 1.1 5.7 0.4 260 79 266 255 18.8 0.3 19.4 18.2 05/18/2005 13:50:00 3.3 1.1 6.5 0.4 3.2 1.2 6.5 0.4 2.7 1.2 6.1 0.4 264 39 272 255 19.5 0.1 20 19.4 05/18/2005 14:00:00 2.8 1.9 6.8 0.4 2.7 2 6.5 0.4 2.3 1.6 6.1 0.4 239 69 340 255 19.6 0.1 20.3 19.4 05/18/2005 14:10:00 3.5 1.3 5.3 0.4 3.4 1.3 5.7 0.4 2.8 1.3 5.7 0.4 278 47 255 255 20 0.2 20.5 19.7 05/18/2005 14:20:00 3.1 1 6.1 1.1 2.9 1 5.7 1.1 2.5 1.1 4.9 0.4 308 26 329 255 20 0.2 20.5 19.7 05/18/2005 14:30:00 3.3 1 6.1 1.5 3.1 1 5.7 1.1 2.6 0.9 5.3 0.7 316 39 270 255 19.7 0 20 19.7 05/18/2005 14:40:00 3 1 5.7 0.4 2.9 1 5.3 0.4 2.3 1 4.6 0.4 280 28 284 255 20.3 0.3 21.1 19.7 05/18/2005 14:50:00 3 1 4.9 0.7 2.8 1.1 5.3 0.4 2.1 1.2 4.9 0.4 287 29 246 255 20.9 0.2 21.4 20.5 05/18/2005 15:00:00 3.5 1.1 6.5 1.1 3.4 1.1 6.5 0.4 2.7 1.3 6.1 0.4 292 19 301 255 20.3 0.1 20.8 20 05/18/2005 15:10:00 4.3 1.1 7.2 1.5 4.2 1.2 6.8 1.5 3.6 1.2 6.5 0.4 305 22 314 255 20.6 0.2 21.1 20 05/18/2005 15:20:00 3.3 1.2 6.1 0.4 3.2 1.3 6.5 0.4 2.7 1.3 5.3 0.4 283 29 288 255 20.4 0.3 21.4 20 05/18/2005 15:30:00 3.5 1.1 7.2 0.7 3.3 1.1 6.5 0.4 3 1.1 6.1 0.4 291 19 291 255 20.4 0.2 21.1 20 05/18/2005 15:40:00 3 1 5.7 0.4 2.8 1 5.3 0.4 2.2 1.1 4.6 0.4 274 32 272 255 20.6 0.1 21.1 20.3 05/18/2005 15:50:00 3.3 1.2 6.8 0.7 3.2 1.3 6.5 0.7 2.6 1.2 5.7 0.4 299 22 312 255 20.9 0 21.1 20.8 05/18/2005 16:00:00 3.1 1.3 7.2 0.4 3 1.3 7.2 0.4 2.3 1.4 7.2 0.4 273 27 308 255 20.6 0 20.8 20.5 05/18/2005 16:10:00 2.9 1.1 4.9 0.4 2.8 1.1 5.3 0.4 2.3 1.1 4.9 0.4 278 36 334 255 20.4 0 20.5 20.3 05/18/2005 16:20:00 3.2 1.2 8 0.7 3.1 1.3 8 0.4 2.4 1.3 5.7 0.4 251 56 189 255 20.3 0 20.5 20 05/18/2005 16:30:00 2.7 1 5.7 0.4 2.7 1.3 6.8 0.4 2.5 1.1 5.7 0.4 164 27 165 255 19.3 0.4 20 18.2 05/18/2005 16:40:00 2.9 1.1 5.3 0.4 2.9 1.1 5.3 0.4 2.6 1.1 5.3 0.4 163 38 174 255 18.1 0 18.5 17.7 05/18/2005 16:50:00 2.8 1.2 6.1 0.4 2.9 1.2 6.1 0.4 2.2 1.5 6.1 0.4 175 23 150 255 18.5 0.5 19.4 17.7 05/18/2005 17:00:00 3.6 1.3 6.8 0.7 3.6 1.3 6.8 1.1 3.1 1.5 6.8 0.4 131 29 126 255 18.8 0 19.1 18.5 05/18/2005 17:10:00 2.3 1 4.2 0.4 2.3 1 4.6 0.4 1.9 1 4.2 0.4 153 35 74 255 18.8 0.2 19.4 18.2 05/18/2005 17:20:00 1 0.8 3.4 0.4 1 0.9 3.4 0.4 0.9 0.8 3 0.4 101 90 171 255 19 0 19.4 18.8 05/18/2005 17:30:00 1.5 0.7 3 0.4 1.4 0.7 3 0.4 1.1 0.8 3.4 0.4 249 35 258 255 18.6 0.3 19.4 18 05/18/2005 17:40:00 1.7 1.2 4.2 0.4 1.5 1.3 4.2 0.4 1.4 1.2 4.2 0.4 56 79 109 255 17.8 0.1 18.2 17.4 05/18/2005 17:50:00 1.5 0.6 3 0.4 1.3 0.7 2.6 0.4 1.1 0.7 2.6 0.4 115 26 102 255 17.8 0.1 18.2 17.4 05/18/2005 18:00:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.5 2.6 0.4 113 21 87 255 18 0 18.5 17.7 05/18/2005 18:10:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 151 29 146 255 18 0 18.5 18 05/18/2005 18:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 162 7 157 255 18 0.1 18.5 17.7 05/18/2005 18:30:00 0.9 0.8 3.4 0.4 0.8 0.8 3 0.4 0.8 0.7 3.4 0.4 263 36 287 255 17.8 0 18.2 17.7 05/18/2005 18:40:00 1.6 0.8 3.4 0.4 1.4 0.9 3.8 0.4 1.2 0.8 3.4 0.4 290 26 283 255 17.8 0 18 17.4 05/18/2005 18:50:00 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.7 0.5 1.9 0.4 292 32 259 255 17.4 0.1 18 17.1 05/18/2005 19:00:00 1.5 0.8 3 0.4 1.4 0.8 3 0.4 1.2 0.7 3 0.4 274 15 290 255 17.1 0 17.1 16.8 05/18/2005 19:10:00 2.1 0.6 3.4 0.4 1.9 0.6 3 0.4 1.6 0.7 3 0.4 286 11 290 255 17.1 0.1 17.1 16.8 05/18/2005 19:20:00 1.8 0.9 4.2 0.4 1.6 1 4.2 0.4 1.3 0.9 4.6 0.4 284 24 304 255 16.6 0 16.8 16.6 05/18/2005 19:30:00 2.5 0.8 4.2 0.4 2.3 0.9 4.6 0.4 1.4 0.7 3 0.4 271 22 259 255 16.4 0.1 16.8 16.3 05/18/2005 19:40:00 2.5 0.7 4.2 0.4 2.4 0.8 4.2 0.4 1.6 0.9 3.8 0.4 271 24 256 255 16.1 0 16.6 16 05/18/2005 19:50:00 2.9 0.7 4.2 0.7 2.8 0.8 4.6 0.4 2.2 0.8 3.8 0.4 287 14 296 255 15.7 0 16.6 15.5 05/18/2005 20:00:00 1.4 0.7 3.4 0.4 1.2 0.7 3.4 0.4 0.7 0.5 3 0.4 272 18 289 255 15.2 0.1 15.7 14.9 05/18/2005 20:10:00 2.3 0.8 4.2 0.4 2.3 0.9 4.9 0.4 1.3 0.8 3.8 0.4 257 19 250 255 14.7 0 15.2 14.6 05/18/2005 20:20:00 2.2 0.9 4.2 0.4 2.1 0.9 3.8 0.4 1.5 1 4.2 0.4 262 14 275 255 14.6 0 15.2 14.4 05/18/2005 20:30:00 2.4 0.9 4.6 0.7 2.2 1 4.9 0.4 1.5 0.9 3.8 0.4 259 15 269 255 14.3 0.1 14.6 13.8 05/18/2005 20:40:00 2.2 0.8 4.6 0.4 2 0.8 3.8 0.4 0.8 0.6 3 0.4 262 21 300 255 13.8 0 14.6 13.5 05/18/2005 20:50:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 0.6 0.5 2.3 0.4 259 15 274 255 13.5 0.1 14.1 13.3 05/18/2005 21:00:00 1.9 0.6 3.4 0.4 1.8 0.6 3 0.4 0.8 0.6 3 0.4 257 14 264 255 13.1 0.2 13.8 12.7 05/18/2005 21:10:00 2.2 0.6 4.2 0.4 2.1 0.7 4.2 0.4 1 0.7 3.4 0.4 261 10 250 255 12.4 0.2 13 11.9 05/18/2005 21:20:00 2.3 0.7 4.2 0.7 2.2 0.8 4.6 0.4 1 0.8 3 0.4 259 12 284 255 11.8 0.1 12.5 11.7 05/18/2005 21:30:00 2 1 4.2 0.4 1.9 0.9 4.2 0.4 0.8 0.6 2.6 0.4 260 11 257 255 11.5 0.1 12.2 11.1 05/18/2005 21:40:00 1.3 0.8 3 0.4 1.2 0.7 3 0.4 0.7 0.5 2.3 0.4 27 41 43 255 11 0.3 11.7 10.6 05/18/2005 21:50:00 1.6 0.5 3 0.4 1.4 0.5 3 0.4 0.9 0.5 2.6 0.4 21 28 25 255 10.6 0.4 11.7 10.1 05/18/2005 22:00:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 0.7 0.5 1.9 0.4 35 7 10 255 10.5 0.3 11.1 9.8 05/18/2005 22:10:00 1.2 0.5 3 0.4 1 0.5 3 0.4 0.5 0.3 1.5 0.4 46 10 49 255 9.6 0.1 10.3 9.3 05/18/2005 22:20:00 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 44 4 40 255 9 0.1 9.6 8.8 05/18/2005 22:30:00 1.3 0.5 2.6 0.4 1.1 0.6 3 0.4 0.6 0.4 1.9 0.4 60 9 57 255 8.7 0 9 8.5 05/18/2005 22:40:00 1.5 0.4 2.3 0.7 1.3 0.4 2.3 0.4 0.4 0.2 1.1 0.4 63 5 64 255 8.5 0 8.8 8.3 05/18/2005 22:50:00 1.7 0.3 2.6 1.1 1.5 0.4 2.6 0.7 0.5 0.3 1.5 0.4 83 12 83 255 8.2 0 8.8 8.3 05/18/2005 23:00:00 2.1 0.3 3 0.7 1.9 0.4 2.6 0.7 0.7 0.4 1.9 0.4 99 12 106 255 7.9 0 8.5 7.8 05/18/2005 23:10:00 1.9 0.4 3.4 0.7 1.8 0.4 3 0.7 0.7 0.4 1.9 0.4 93 9 74 255 7.4 0.1 7.8 7.3 05/18/2005 23:20:00 2.2 0.4 3.4 1.1 2.1 0.3 3 0.7 1 0.4 1.9 0.4 98 9 94 255 7.1 0.1 7.5 6.7 05/18/2005 23:30:00 2.2 0.4 3 1.1 2 0.3 2.6 1.1 0.9 0.5 2.6 0.4 110 12 105 255 6.7 0 7 6.7 05/18/2005 23:40:00 1.6 0.6 3.4 0.4 1.5 0.6 3.4 0.4 0.6 0.3 1.9 0.4 119 13 74 255 6.5 0.2 6.7 6.2 05/18/2005 23:50:00 2.3 0.6 4.2 0.4 2.2 0.6 3.8 0.4 1.3 0.7 2.6 0.4 123 11 113 255 6.2 0 6.2 6 05/19/2005 00:00:00 2.5 0.7 4.6 1.1 2.3 0.8 4.2 0.4 1.3 0.7 2.6 0.4 115 13 123 255 6.4 0 7 6.2 05/19/2005 00:10:00 2.3 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1 0.5 2.6 0.4 118 12 132 255 6.2 0 6.7 6.2 05/19/2005 00:20:00 2.6 0.6 4.2 1.1 2.6 0.6 4.2 1.1 1.8 0.6 3.4 0.4 126 12 116 255 6.1 0.1 6.7 5.7 05/19/2005 00:30:00 2 0.7 3.4 0.4 1.9 0.8 3.8 0.4 1 0.6 2.6 0.4 130 8 126 255 6.2 0 6.5 6 05/19/2005 00:40:00 2.5 0.7 3.8 0.7 2.4 0.7 3.8 0.7 1.4 0.6 3 0.4 122 8 116 255 5.6 0.1 6 5.5 05/19/2005 00:50:00 3.5 0.5 4.9 2.3 3.4 0.6 4.9 1.9 2 0.6 4.2 0.4 118 10 112 255 5.2 0 5.5 5 05/19/2005 01:00:00 3 0.8 4.9 1.5 3 0.8 4.9 1.1 1.7 0.6 3.8 0.4 115 13 103 255 5.1 0 5.2 5 05/19/2005 01:10:00 3 0.6 4.6 0.7 2.9 0.7 4.6 0.7 1.9 0.5 3 0.7 121 12 137 255 5 0 5.2 4.8 05/19/2005 01:20:00 2.9 0.7 4.6 1.5 2.9 0.7 4.6 1.5 1.8 0.6 3.4 0.4 122 13 131 255 5.3 0 5.5 5.2 05/19/2005 01:30:00 2.7 0.7 4.9 0.7 2.6 0.7 4.6 0.7 1.3 0.7 3 0.4 113 15 127 255 5.2 0.1 5.7 5 05/19/2005 01:40:00 2.8 0.5 3.8 1.1 2.7 0.5 4.2 1.1 1.4 0.6 3 0.4 106 12 148 255 5 0 5 5 05/19/2005 01:50:00 2.6 0.6 3.8 1.1 2.5 0.6 3.8 1.1 1.5 0.6 3 0.4 103 10 113 255 4.8 0.1 5 4.5 05/19/2005 02:00:00 2.9 0.5 4.2 1.5 2.9 0.5 4.6 1.5 1.7 0.6 3 0.4 112 10 104 255 4.4 0.1 4.5 4.3 05/19/2005 02:10:00 2.4 0.6 4.2 1.1 2.2 0.7 3.8 0.7 1 0.6 2.6 0.4 108 11 104 255 4.1 0 4.3 4 05/19/2005 02:20:00 2.5 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.3 0.5 2.6 0.4 105 8 106 255 4.1 0 4.3 4 05/19/2005 02:30:00 3 0.5 3.8 1.5 2.9 0.5 3.8 1.5 1.9 0.6 3 0.4 113 9 101 255 4 0 4.3 4 05/19/2005 02:40:00 2.8 0.6 4.2 1.1 2.7 0.6 4.2 1.1 1.5 0.6 3 0.4 114 10 113 255 4 0 4.3 4 05/19/2005 02:50:00 2.5 0.5 3.4 0.7 2.4 0.5 3.4 0.7 1.5 0.5 2.6 0.4 114 9 112 255 4.2 0 4.5 4 05/19/2005 03:00:00 2.8 0.5 4.2 1.1 2.7 0.5 4.2 1.1 1.7 0.6 3 0.4 114 9 118 255 4.1 0 4.3 4 05/19/2005 03:10:00 3 0.5 4.2 1.1 2.9 0.6 4.2 1.5 1.9 0.6 3 0.4 111 9 108 255 4.1 0 4.3 3.8 05/19/2005 03:20:00 3.2 0.5 4.2 1.1 3.1 0.5 4.2 1.5 1.8 0.6 3.4 0.4 108 8 98 255 4.3 0 4.5 4 05/19/2005 03:30:00 3.3 0.6 4.9 1.9 3.2 0.6 4.6 1.9 2 0.8 3.8 0.4 107 9 102 255 4.3 0 4.5 4 05/19/2005 03:40:00 3.5 0.5 4.6 2.3 3.4 0.5 4.2 1.9 2.3 0.6 3.8 0.4 107 9 81 255 4.8 0 4.8 4.5 05/19/2005 03:50:00 3.2 0.5 4.2 1.9 3.1 0.5 4.2 1.1 1.9 0.6 3.4 0.4 109 9 111 255 4.8 0.1 5 4.5 05/19/2005 04:00:00 3.3 0.6 4.6 1.5 3.3 0.6 4.2 1.1 2.3 0.7 3.8 0.4 107 9 91 255 4.8 0.2 5.2 4.5 05/19/2005 04:10:00 3.2 0.5 4.6 1.5 3.2 0.5 4.6 1.5 2 0.7 3.8 0.4 114 10 125 255 5.2 0.2 5.7 5 05/19/2005 04:20:00 3 0.7 4.6 1.1 2.9 0.7 4.6 0.7 1.7 0.5 3 0.4 115 12 109 255 4.8 0.2 5 4.5 05/19/2005 04:30:00 2.9 0.6 4.2 1.5 2.9 0.6 4.2 1.1 1.7 0.6 3.4 0.4 113 13 115 255 5 0.2 5.5 4.5 05/19/2005 04:40:00 2.5 0.8 4.9 0.4 2.5 0.8 4.2 0.4 1.3 0.7 2.6 0.4 116 19 104 255 5.3 0 5.5 5.2 05/19/2005 04:50:00 2.6 0.7 4.2 1.1 2.6 0.7 4.2 1.1 1.6 0.7 3.4 0.4 117 15 114 255 5.8 0.4 6.5 5.2 05/19/2005 05:00:00 2.4 0.7 3.8 0.7 2.4 0.7 4.2 0.7 1.2 0.7 3 0.4 95 17 88 255 6.4 0.1 6.7 6.2 05/19/2005 05:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 72 9 74 255 6.1 0 6.5 6 05/19/2005 05:20:00 3 0.7 4.6 1.1 3 0.7 4.6 0.7 1.7 0.8 3.8 0.4 95 5 93 255 5.9 0 6 5.7 05/19/2005 05:30:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 2.3 2.4 0.6 4.2 0.7 96 7 95 255 6.5 0.3 7.3 6 05/19/2005 05:40:00 2.2 0.5 3.8 1.1 2.2 0.5 3.8 1.1 1.3 0.6 3.4 0.4 96 8 97 255 7.6 0.3 8.3 7.3 05/19/2005 05:50:00 1.7 0.4 3 0.7 1.7 0.4 3 0.7 1.1 0.4 2.3 0.4 90 5 87 255 8 0 8.3 7.8 05/19/2005 06:00:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.6 0.4 1.9 0.4 85 9 72 255 8.9 0.5 9.8 8.3 05/19/2005 06:10:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 0.9 0.6 2.6 0.4 79 20 93 255 10.4 0.3 11.1 9.8 05/19/2005 06:20:00 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 0.6 0.4 2.3 0.4 15 27 55 255 11.3 0.1 11.7 11.1 05/19/2005 06:30:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 19 19 32 255 11.8 0.1 12.2 11.7 05/19/2005 06:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 347 22 349 255 11.5 0.2 12.2 11.1 05/19/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 354 9 345 255 11.4 0.1 11.9 11.1 05/19/2005 07:00:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 9 7 11 255 11.1 0 11.7 10.9 05/19/2005 07:10:00 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 358 16 20 255 11.3 0.1 11.7 11.1 05/19/2005 07:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 2.3 0.4 356 22 336 255 12.4 0.4 13.3 11.7 05/19/2005 07:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 17 18 13 255 13.3 0.3 13.8 12.7 05/19/2005 07:40:00 1.1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 6 16 26 255 13.4 0 14.1 13.3 05/19/2005 07:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 355 17 353 255 13.2 0 13.5 13 05/19/2005 08:00:00 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 7 38 315 255 13.7 0.1 14.1 13.3 05/19/2005 08:10:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 354 19 336 255 13.7 0.1 14.1 13.3 05/19/2005 08:20:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.2 0.5 2.6 0.4 3 12 354 255 14.3 0 14.6 13.8 05/19/2005 08:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.7 0.4 1.9 0.4 2 15 358 255 14.3 0.1 14.6 13.8 05/19/2005 08:40:00 0.8 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 354 15 17 255 14.6 0.2 15.2 13.8 05/19/2005 08:50:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 17 14 353 255 14.9 0 15.2 14.9 05/19/2005 09:00:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 356 38 30 255 15.4 0.3 16 14.9 05/19/2005 09:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 308 51 336 255 16.3 0.1 16.8 16 05/19/2005 09:20:00 1.8 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.1 0.8 3 0.4 349 22 345 255 17 0.1 17.4 16.8 05/19/2005 09:30:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.8 3.4 0.4 355 22 352 255 17.8 0.3 18.8 17.4 05/19/2005 09:40:00 2.7 0.7 4.2 1.5 2.6 0.7 4.2 1.5 2 0.8 4.6 0.4 350 16 340 255 18.2 0 18.8 18.2 05/19/2005 09:50:00 2.4 0.7 3.8 0.4 2.4 0.7 3.8 0.4 1.8 0.7 3.8 0.4 16 20 11 255 18.4 0.1 18.8 18.2 05/19/2005 10:00:00 2.1 1 4.2 0.4 2.1 1 4.2 0.4 1.7 1 4.2 0.4 9 27 24 255 18.5 0.1 19.1 18.2 05/19/2005 10:10:00 2.3 0.9 4.6 0.4 2.2 0.9 4.2 0.4 1.8 0.8 3.4 0.4 1 19 353 255 18.8 0 19.4 18.5 05/19/2005 10:20:00 2.2 0.7 4.2 0.4 2.2 0.6 4.2 0.4 1.7 0.7 3.8 0.4 14 26 358 255 18.9 0.2 19.7 18.5 05/19/2005 10:30:00 1.9 1 4.2 0.4 1.7 0.9 3.8 0.4 1.4 1 3.4 0.4 11 49 348 255 18.7 0.3 19.4 18.2 05/19/2005 10:40:00 2.3 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.7 0.9 3.8 0.4 331 47 0 255 19.2 0.3 20 18.2 05/19/2005 10:50:00 1.6 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.4 0.7 3 0.4 33 35 3 255 19.7 0.2 20.3 19.4 05/19/2005 11:00:00 2 0.7 3.4 0.4 2 0.6 3.4 0.4 1.4 0.7 3 0.4 0 32 349 255 19.7 0 20 19.4 05/19/2005 11:10:00 1.4 0.7 3.4 0.4 1.5 0.7 3.8 0.4 1.2 0.7 3 0.4 34 23 14 255 20 0.1 20.3 19.4 05/19/2005 11:20:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 77 32 80 255 20 0 20.5 20 05/19/2005 11:30:00 1.9 0.6 3.8 0.4 1.9 0.6 3.8 0.4 1.4 0.6 3 0.4 2 18 3 255 20.6 0.3 21.4 20 05/19/2005 11:40:00 2.1 0.7 3.8 0.4 2 0.7 3.8 0.4 1.3 0.8 3.8 0.4 5 19 351 255 21.6 0.2 22.3 21.1 05/19/2005 11:50:00 2.4 1 4.6 0.4 2.4 1 4.9 0.4 1.8 1 4.2 0.4 3 17 9 255 22.1 0.2 22.9 21.7 05/19/2005 12:00:00 2.2 0.6 3.8 0.4 2.1 0.6 3.8 0.4 1.6 0.8 3.4 0.4 332 29 301 255 22.6 0.2 23.2 22.3 05/19/2005 12:10:00 2.3 0.9 4.6 0.4 2.2 0.9 4.2 0.4 1.7 0.9 3.8 0.4 358 24 13 255 23.3 0 23.8 22.9 05/19/2005 12:20:00 2.5 0.8 4.6 0.7 2.3 0.8 4.2 0.4 1.8 0.8 4.2 0.4 324 24 296 255 22.2 0.3 23.2 21.7 05/19/2005 12:30:00 1.7 0.9 4.2 0.4 1.7 0.9 4.2 0.4 1.1 0.8 3.4 0.4 32 36 10 255 22.9 0.1 23.2 22.6 05/19/2005 12:40:00 2.4 0.9 4.9 0.4 2.2 1 4.9 0.4 1.6 1 4.2 0.4 359 29 351 255 23.1 0.2 23.5 22.6 05/19/2005 12:50:00 2 1 4.2 0.4 1.9 0.9 4.2 0.4 1.4 0.8 4.6 0.4 2 45 345 255 23.8 0.3 24.4 23.2 05/19/2005 13:00:00 2.8 1.3 7.2 0.7 2.7 1.3 7.6 0.7 2 1 5.3 0.4 341 19 350 255 23.5 0.1 24.1 23.5 05/19/2005 13:10:00 2.6 1 4.9 0.4 2.6 1 4.9 0.4 2 1 4.2 0.4 14 20 17 255 24.1 0 24.4 23.8 05/19/2005 13:20:00 2.9 1 6.1 0.7 2.7 1 5.3 0.7 2.1 1 4.6 0.4 343 19 351 255 24.4 0 24.7 24.1 05/19/2005 13:30:00 3 1.2 4.9 0.4 2.9 1.3 5.3 0.4 2.5 1.2 5.3 0.4 17 39 49 255 24.5 0 25 24.4 05/19/2005 13:40:00 4.2 1.2 7.6 0.4 4 1.3 7.6 0.7 3.2 1.2 6.1 0.4 356 22 57 255 25 0.2 25.6 24.7 05/19/2005 13:50:00 3.1 1.1 5.7 0.4 3 1.1 5.7 0.4 2.4 1.1 5.3 0.4 337 24 8 255 25.7 0 25.9 25 05/19/2005 14:00:00 4.1 1.2 6.8 0.7 3.8 1.1 6.8 0.7 3.2 1.3 6.1 0.4 330 24 345 255 25.2 0 25.6 25 05/19/2005 14:10:00 3.6 1.4 6.8 0.4 3.5 1.5 6.8 0.4 2.5 1.5 6.1 0.4 349 38 2 255 25.7 0.1 26.2 25.6 05/19/2005 14:20:00 4.7 1.2 7.2 1.9 4.7 1.2 7.2 1.9 3.6 1.3 6.5 0.4 9 18 13 255 25.7 0 26.2 25.6 05/19/2005 14:30:00 3.5 1.3 7.2 0.7 3.4 1.4 7.2 0.7 2.5 1.3 6.1 0.4 23 38 6 255 25.7 0 26.2 25.6 05/19/2005 14:40:00 3.8 1.7 8.4 0.7 3.7 1.7 8.4 0.4 2.9 1.3 7.2 0.4 16 24 38 255 25.6 0 25.9 25.3 05/19/2005 14:50:00 4.9 1.2 7.2 2.3 4.8 1.3 7.6 2.3 3.6 1.5 7.2 0.4 14 16 29 255 25.7 0 26.2 25.6 05/19/2005 15:00:00 4.7 1.2 8 1.5 4.5 1.2 8 1.1 3.7 1.3 6.5 0.4 359 22 27 255 26 0 26.5 25.9 05/19/2005 15:10:00 4.1 1.1 6.8 1.9 4.1 1.1 7.2 1.5 2.9 1.2 6.5 0.4 9 17 16 255 26.4 0 26.8 26.2 05/19/2005 15:20:00 5.8 1.2 8.4 2.6 5.7 1.2 8.4 2.3 4.2 1.5 8.4 0.7 8 15 17 255 26.6 0 26.8 26.2 05/19/2005 15:30:00 6.4 1.1 8.8 2.3 6.3 1.1 9.1 2.3 5.3 1.3 8.4 2.3 23 15 19 255 25.7 0 26.2 25.3 05/19/2005 15:40:00 4.3 0.9 6.5 2.3 4.2 0.9 6.5 1.9 3.3 1.1 5.7 0.7 17 15 21 255 25.7 0 25.9 25.6 05/19/2005 15:50:00 5.2 0.7 7.6 3.4 5.2 0.7 7.6 3 3.8 1.1 6.1 1.1 17 13 359 255 25.7 0.2 26.2 25.3 05/19/2005 16:00:00 4.3 1.3 7.2 1.5 4.2 1.3 7.6 1.1 3.1 1.3 6.5 0.4 17 19 21 255 25.2 0 25.6 25 05/19/2005 16:10:00 5.6 1.2 8.8 2.6 5.5 1.2 8.8 2.3 4.1 1.6 8 0.7 9 15 12 255 25.2 0 25.6 25 05/19/2005 16:20:00 5.3 1.1 8 2.3 5.2 1.2 8 1.9 3.8 1.3 6.8 0.4 358 17 12 255 24.7 0.3 25.3 23.8 05/19/2005 16:30:00 5.1 1.1 7.6 1.9 5 1.1 8 1.5 3.8 1.4 7.2 0.4 9 13 4 255 23.4 0.1 23.8 23.5 05/19/2005 16:40:00 5.3 1.2 8 1.9 5.3 1.2 8 1.9 4 1.5 8.8 1.1 12 12 28 255 23.8 0 23.8 23.5 05/19/2005 16:50:00 5.5 1.1 8.4 2.6 5.5 1.1 8.4 2.6 4 1.5 7.6 0.7 14 15 4 255 23.6 0 23.8 23.5 05/19/2005 17:00:00 5.6 1 8 2.6 5.5 1.1 8.4 2.3 4.2 1.2 7.6 1.5 14 19 28 255 23.3 0 23.5 23.2 05/19/2005 17:10:00 5.4 0.8 7.2 3.4 5.3 0.8 7.2 3.4 4.2 1.2 6.8 1.1 14 17 24 255 23.1 0 23.5 23.2 05/19/2005 17:20:00 5.1 1.2 8 1.5 5 1.2 8 1.5 3.6 1.3 6.8 0.7 9 17 0 255 23 0 23.5 22.9 05/19/2005 17:30:00 6.1 1 8.4 3.4 6 1 8.4 3.4 5 1.2 8.4 2.3 33 15 27 255 22.9 0 23.5 22.9 05/19/2005 17:40:00 5.9 1 9.1 3.4 5.9 1.1 9.1 3.4 4.6 1.1 8 2.3 25 14 17 255 22.8 0.1 23.5 22.6 05/19/2005 17:50:00 6.4 1.1 8.8 2.6 6.4 1.1 8.8 2.6 5.1 1.3 7.6 1.9 24 12 21 255 22.4 0 23.2 22 05/19/2005 18:00:00 6.3 1.1 9.1 2.6 6.2 1.1 8.8 2.6 4.9 1.3 8 1.5 20 11 15 255 21.7 0.2 22.3 21.1 05/19/2005 18:10:00 4.9 1.3 8 0.7 4.8 1.3 7.6 0.7 3.5 1.6 7.2 0.4 15 15 14 255 20.8 0.2 21.1 20.3 05/19/2005 18:20:00 5.2 1 7.6 3 5.2 1 7.6 3 3.8 1.2 6.8 0.7 18 15 32 255 20.5 0.1 21.1 20.3 05/19/2005 18:30:00 4.8 1 7.2 1.9 4.8 1 7.2 1.9 3.4 1.4 6.8 0.4 18 15 16 255 20.7 0.1 21.1 20.5 05/19/2005 18:40:00 5 1.2 8 2.3 5 1.2 7.6 1.9 3.8 1.3 6.8 1.5 23 15 6 255 21.2 0 21.7 20.8 05/19/2005 18:50:00 5.7 1.1 9.5 3 5.7 1.1 9.1 2.3 4.3 1.4 8 0.4 20 12 25 255 21 0.2 21.4 20.5 05/19/2005 19:00:00 5.5 1.5 9.1 2.3 5.5 1.5 9.1 2.3 3.7 1.8 8.4 0.4 14 12 34 255 20.5 0 21.1 20.3 05/19/2005 19:10:00 6.1 1 8.4 3.8 6.1 1 8.4 3.8 4.7 1.2 7.6 1.5 17 11 17 255 20.2 0 20.5 20 05/19/2005 19:20:00 5.7 1.1 8.8 2.6 5.7 1.1 8.4 2.6 4.1 1.3 8 0.7 17 13 8 255 20 0 20.5 19.7 05/19/2005 19:30:00 5.2 1.2 8 2.6 5.1 1.2 8 2.6 3.7 1.5 7.6 0.7 20 13 17 255 19.7 0 20 19.4 05/19/2005 19:40:00 4.5 0.8 6.8 2.3 4.5 0.9 6.8 1.9 3.3 1.1 5.7 0.7 17 17 32 255 19.4 0 20 19.1 05/19/2005 19:50:00 5.1 1 7.6 2.6 5.1 1.1 7.6 2.6 3.8 1.3 6.8 0.7 22 11 20 255 19.2 0 19.7 19.1 05/19/2005 20:00:00 3.7 1.1 6.5 1.1 3.7 1.1 6.1 0.7 2.6 1.3 5.7 0.4 19 12 37 255 18.9 0.2 19.7 18.5 05/19/2005 20:10:00 4.6 0.8 6.8 2.6 4.6 0.8 6.5 2.6 3.3 1.1 6.1 0.4 17 11 27 255 18.2 0 18.5 18 05/19/2005 20:20:00 3.8 0.7 5.7 1.9 3.7 0.8 5.7 1.5 2.3 1 4.6 0.4 15 17 38 255 17.9 0.1 18.2 17.4 05/19/2005 20:30:00 4.2 0.8 6.5 1.9 4.1 0.9 6.1 1.5 2.8 1 5.3 0.4 13 12 3 255 17.3 0 17.7 17.1 05/19/2005 20:40:00 4.1 0.7 5.3 1.9 4.1 0.7 5.3 1.9 3 0.9 5.3 0.7 19 13 31 255 16.9 0 17.1 16.8 05/19/2005 20:50:00 3.8 0.9 6.1 1.5 3.8 0.9 6.1 1.5 3 0.9 5.3 0.4 22 12 14 255 17.1 0 17.1 16.8 05/19/2005 21:00:00 3.4 0.8 4.9 1.5 3.3 0.8 4.9 1.5 2.3 1.1 4.2 0.4 24 15 31 255 16.5 0.3 17.1 16 05/19/2005 21:10:00 3.8 0.6 5.7 1.5 3.7 0.7 6.1 1.5 2.5 0.9 5.3 0.4 15 11 14 255 15.7 0.1 16.3 15.5 05/19/2005 21:20:00 3.4 0.6 4.9 1.9 3.3 0.7 4.9 1.5 2.1 1 4.2 0.4 18 12 17 255 15.3 0.1 15.7 15.2 05/19/2005 21:30:00 3.2 0.5 4.6 1.5 3.1 0.6 4.6 1.5 2.1 0.8 4.2 0.4 22 10 16 255 14.8 0.2 15.2 14.4 05/19/2005 21:40:00 2.7 0.4 3.8 1.9 2.6 0.4 3.4 1.5 1.8 0.6 3 0.4 32 9 43 255 14 0.1 14.6 13.5 05/19/2005 21:50:00 2.5 0.4 3.8 1.5 2.3 0.5 3.8 1.1 1.3 0.6 2.6 0.4 41 9 42 255 13.3 0.3 13.8 12.7 05/19/2005 22:00:00 2 0.4 2.6 1.1 1.9 0.4 2.6 1.1 0.7 0.4 1.9 0.4 36 9 37 255 12.4 0 13.3 12.2 05/19/2005 22:10:00 1.8 0.3 2.6 1.1 1.6 0.4 2.3 0.7 0.7 0.3 1.9 0.4 34 4 35 255 11.9 0.2 12.7 11.7 05/19/2005 22:20:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.5 0.3 1.5 0.4 57 16 35 255 11.5 0.2 12.2 11.1 05/19/2005 22:30:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 88 35 49 255 11.1 0 11.7 10.9 05/19/2005 22:40:00 1.2 0.7 2.6 0.4 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 102 41 45 255 10.7 0.1 11.1 10.3 05/19/2005 22:50:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 115 53 46 255 10.6 0.2 11.1 10.3 05/19/2005 23:00:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 104 41 92 255 9.8 0.2 10.6 9.6 05/19/2005 23:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 16 17 29 255 9.6 0 9.8 9.6 05/19/2005 23:20:00 0.7 0.5 2.3 0.4 0.5 0.3 1.5 0.4 1.1 0.6 2.3 0.4 113 47 32 255 9.3 0.1 9.8 9 05/19/2005 23:30:00 2.1 0.7 3 0.4 2 0.8 3.4 0.4 1.8 0.5 3 0.7 142 6 152 255 8.8 0.1 9.6 8.5 05/19/2005 23:40:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 0.8 0.5 1.9 0.4 112 18 100 255 8.5 0 9 8.5 05/19/2005 23:50:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 114 5 118 255 8.3 0 8.8 8.3 05/20/2005 00:00:00 1.7 0.4 2.6 0.4 1.4 0.5 2.6 0.4 0.8 0.4 1.9 0.4 98 11 110 255 8.3 0 8.8 8.3 05/20/2005 00:10:00 2.2 0.6 3.4 0.4 2.1 0.7 3 0.4 1.3 0.6 2.3 0.4 101 22 88 255 8 0 8.5 7.8 05/20/2005 00:20:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 1.2 0.5 2.3 0.4 110 16 106 255 7.8 0 8.3 7.8 05/20/2005 00:30:00 2.4 0.3 3.4 1.5 2.3 0.3 3 1.5 1.5 0.5 2.6 0.4 99 7 98 255 7.6 0 8 7.5 05/20/2005 00:40:00 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 1.5 0.7 3.8 0.4 82 15 79 255 7.4 0.1 7.8 7.3 05/20/2005 00:50:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.5 0.5 2.6 0.4 76 9 82 255 7.3 0 7.8 7.3 05/20/2005 01:00:00 2.1 0.5 3 0.7 1.9 0.5 3 0.4 0.7 0.4 2.3 0.4 108 14 114 255 7.3 0 7.8 7 05/20/2005 01:10:00 2.1 0.4 3 1.1 1.8 0.4 2.6 0.7 0.6 0.4 1.5 0.4 112 4 110 255 6.9 0 7.3 6.7 05/20/2005 01:20:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 1.1 1.3 0.4 2.3 0.4 117 10 109 255 6.6 0 7 6.5 05/20/2005 01:30:00 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.9 1.1 0.5 2.3 0.4 91 9 94 255 6.5 0 7 6.2 05/20/2005 01:40:00 2.3 0.5 3.4 1.1 2.1 0.6 3.8 0.7 0.7 0.4 1.9 0.4 116 12 105 255 6.2 0 6.7 6.2 05/20/2005 01:50:00 2.6 0.5 3.8 1.1 2.4 0.6 3.8 0.7 0.9 0.6 2.3 0.4 108 6 112 255 6.2 0 6.7 6.2 05/20/2005 02:00:00 2.2 0.6 3.8 1.5 2.1 0.6 3.8 1.1 0.8 0.6 3 0.4 105 5 106 255 6.1 0 6.5 6 05/20/2005 02:10:00 2.3 0.5 3.8 1.1 2.1 0.5 3.8 0.4 1 0.6 2.6 0.4 115 8 112 255 5.9 0.1 6.2 5.7 05/20/2005 02:20:00 1.5 0.6 3 0.4 1.3 0.7 3.4 0.4 0.5 0.4 1.9 0.4 113 10 115 255 5.7 0 6.2 5.7 05/20/2005 02:30:00 3.3 0.7 4.9 1.5 3.3 0.7 4.9 1.1 2.2 0.7 4.2 0.4 116 8 115 255 6.1 0.2 7 5.7 05/20/2005 02:40:00 3.3 0.8 4.9 1.5 3.2 0.8 4.9 1.5 1.8 0.8 3.8 0.4 115 11 108 255 6.6 0 7 6.2 05/20/2005 02:50:00 1.7 0.8 3.8 0.4 1.5 0.8 3.4 0.4 0.6 0.5 2.6 0.4 110 13 104 255 6.1 0.1 6.5 5.7 05/20/2005 03:00:00 1.7 0.3 2.6 0.7 1.4 0.4 2.3 0.7 0.4 0.2 1.5 0.4 100 8 99 255 5.9 0 6 5.7 05/20/2005 03:10:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.4 0.1 1.1 0.4 107 15 103 255 5.8 0.1 6 5.7 05/20/2005 03:20:00 2.6 0.5 3.8 1.1 2.5 0.5 3.4 1.1 1.4 0.5 2.6 0.4 114 10 125 255 5.6 0 5.7 5.2 05/20/2005 03:30:00 2.6 0.7 4.2 0.7 2.4 0.7 4.2 0.7 1.5 0.5 3.4 0.4 117 12 110 255 5.2 0 5.5 5 05/20/2005 03:40:00 2.8 0.4 3.8 1.5 2.6 0.4 3.4 1.5 1.3 0.5 2.6 0.4 108 10 115 255 5.3 0 5.5 5.2 05/20/2005 03:50:00 2.4 0.7 3.4 0.7 2.2 0.7 3.4 0.4 1.5 0.6 3 0.4 119 13 124 255 5.4 0 5.7 5.2 05/20/2005 04:00:00 1.9 0.5 3.8 0.7 1.7 0.6 3.8 0.4 1.4 0.5 2.3 0.4 130 9 124 255 5.5 0 5.7 5.5 05/20/2005 04:10:00 2.3 0.5 3.4 1.1 2.2 0.6 3.4 0.4 1.5 0.5 2.6 0.4 120 9 118 255 5.7 0.1 6.2 5.5 05/20/2005 04:20:00 2.6 0.6 4.2 1.1 2.4 0.7 3.8 0.7 1.7 0.6 3 0.4 122 9 115 255 6.3 0.1 6.7 6 05/20/2005 04:30:00 2.3 0.6 3.8 0.7 2.2 0.6 3.8 0.7 1.6 0.8 3.4 0.4 130 10 124 255 7.1 0.3 7.8 6.7 05/20/2005 04:40:00 1.6 0.7 3.4 0.4 1.4 0.8 3.4 0.4 0.8 0.6 2.6 0.4 125 14 122 255 8.1 0 8.3 7.8 05/20/2005 04:50:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.3 0.6 2.3 0.4 124 14 114 255 8 0 8.3 7.8 05/20/2005 05:00:00 2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.3 0.6 3 0.4 129 10 132 255 8 0.1 8.3 7.8 05/20/2005 05:10:00 1.8 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1 0.6 2.6 0.4 126 13 115 255 8.4 0 8.5 8.3 05/20/2005 05:20:00 1.7 0.6 3.4 0.4 1.6 0.7 3.4 0.4 0.9 0.5 2.6 0.4 124 14 127 255 8.4 0 8.5 8.3 05/20/2005 05:30:00 2.8 0.6 4.2 1.5 2.7 0.7 4.2 1.1 1.9 0.6 3.4 0.7 135 13 132 255 8.5 0 8.8 8.5 05/20/2005 05:40:00 1.9 0.7 3.8 0.4 1.7 0.7 3.4 0.4 1 0.6 2.6 0.4 127 13 138 255 8.7 0.1 9 8.5 05/20/2005 05:50:00 1.8 0.5 3.4 0.7 1.6 0.6 3 0.4 0.9 0.5 2.6 0.4 126 13 113 255 9 0 9 9 05/20/2005 06:00:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.3 0.6 2.6 0.4 128 15 116 255 9.4 0.2 9.8 9 05/20/2005 06:10:00 1.9 0.5 3 0.7 1.8 0.5 3 0.4 1.3 0.6 3 0.4 136 12 136 255 10.2 0.2 10.6 9.8 05/20/2005 06:20:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 143 10 138 255 10.9 0.1 11.7 10.6 05/20/2005 06:30:00 0.7 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 146 9 140 255 11.5 0 11.7 11.1 05/20/2005 06:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 148 4 143 255 12.1 0.3 12.7 11.7 05/20/2005 06:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 151 0 151 255 13.1 0.3 13.8 12.5 05/20/2005 07:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 21 196 255 13.9 0.3 14.6 13.3 05/20/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 197 0 255 255 14.6 0.1 15.2 14.4 05/20/2005 07:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 41 283 255 15.2 0.1 15.7 14.9 05/20/2005 07:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 321 35 342 255 15.7 0 16 15.7 05/20/2005 07:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 29 22 21 255 15.9 0 16.3 15.7 05/20/2005 07:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 29 21 44 255 16.3 0.1 16.6 16 05/20/2005 08:00:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 341 45 298 255 16.8 0.1 17.1 16.3 05/20/2005 08:10:00 1.5 0.7 3 0.4 1.3 0.6 3 0.4 1 0.6 2.6 0.4 302 28 320 255 17.1 0 17.7 16.8 05/20/2005 08:20:00 2.4 0.6 4.2 1.1 2.2 0.6 3.8 0.4 1.5 0.8 3.8 0.4 304 22 299 255 17.5 0 18 17.4 05/20/2005 08:30:00 1.9 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.2 0.8 3.4 0.4 276 35 237 255 17.7 0.2 18.5 17.4 05/20/2005 08:40:00 2.5 1 4.9 0.4 2.4 1 5.3 0.4 1.9 1.1 4.6 0.4 277 36 254 255 17.8 0.2 18.5 17.4 05/20/2005 08:50:00 1.9 1 4.6 0.4 1.7 1.1 4.6 0.4 1.4 1 4.2 0.4 277 43 256 255 18 0.1 18.5 17.7 05/20/2005 09:00:00 3 0.7 5.3 0.4 3 0.7 4.9 0.7 2.5 0.8 4.6 0.4 258 19 295 255 17.8 0 18.2 17.4 05/20/2005 09:10:00 2.6 0.9 4.9 0.7 2.6 0.9 4.9 0.7 2 1 4.9 0.4 255 23 302 255 18 0.1 18.5 17.4 05/20/2005 09:20:00 3 1 4.9 0.4 2.9 1 4.9 0.4 2.6 1.2 4.9 0.4 262 21 270 255 18.2 0.1 18.8 17.7 05/20/2005 09:30:00 2.7 0.8 4.9 0.4 2.7 0.8 4.6 0.4 1.8 1 4.2 0.4 249 23 250 255 18.4 0.3 19.1 17.7 05/20/2005 09:40:00 2.9 0.9 5.3 0.4 2.9 0.8 4.9 0.4 2.3 1 4.6 0.4 249 21 268 255 18.5 0.2 19.4 18.2 05/20/2005 09:50:00 2.8 1.1 6.1 0.4 2.7 1.2 6.5 0.4 1.9 1.2 5.7 0.4 247 36 255 255 19.1 0.2 20 18.5 05/20/2005 10:00:00 2.5 1.2 5.3 0.4 2.5 1.2 5.3 0.4 2 1.1 4.6 0.4 270 32 259 255 19 0.1 19.4 18.5 05/20/2005 10:10:00 3.5 1.1 5.7 0.4 3.4 1.2 6.1 0.4 2.7 1.4 6.1 0.4 281 32 257 255 18.6 0.2 19.4 18.2 05/20/2005 10:20:00 3.3 0.9 5.7 0.4 3.2 1 5.3 0.4 2.7 1.1 4.9 0.4 294 20 294 255 18.3 0.1 18.8 18 05/20/2005 10:30:00 3.2 1.3 6.1 0.4 3.1 1.3 6.1 0.4 2.7 1.3 5.7 0.4 293 26 295 255 17.8 0.1 18.2 17.4 05/20/2005 10:40:00 2.8 0.9 4.6 0.4 2.7 0.9 4.9 0.4 2.1 0.9 4.6 0.4 282 22 254 255 18 0.2 18.5 17.7 05/20/2005 10:50:00 2.8 0.8 5.3 1.1 2.7 0.8 4.6 0.4 2 0.9 4.6 0.4 275 30 277 255 18.5 0.1 19.1 18.2 05/20/2005 11:00:00 1.8 1.2 4.9 0.4 1.7 1.3 5.3 0.4 1.4 1.1 4.6 0.4 256 38 253 255 18.5 0.6 19.4 17.7 05/20/2005 11:10:00 2.7 1 4.6 0.4 2.6 1 4.6 0.4 2.3 1.2 5.7 0.4 264 22 265 255 18.6 0.3 19.4 17.7 05/20/2005 11:20:00 2.6 1.2 5.7 0.4 2.5 1.3 5.3 0.4 2 1.2 4.9 0.4 273 36 323 255 19.2 0.3 20 18.5 05/20/2005 11:30:00 3.1 1 6.1 1.1 3 1 5.7 0.7 2.4 1.2 5.3 0.4 281 36 314 255 19.9 0.1 20.5 19.4 05/20/2005 11:40:00 4 1.3 6.8 1.1 3.8 1.3 7.2 0.7 3.3 1.3 6.8 0.7 298 18 306 255 19.5 0.2 20.3 19.1 05/20/2005 11:50:00 4.2 1 6.5 1.9 4 1.1 6.5 1.5 3.4 1.3 6.5 0.4 314 16 303 255 20.3 0 20.5 20 05/20/2005 12:00:00 3.5 1.4 6.1 0.4 3.4 1.5 6.1 0.4 2.9 1.4 6.8 0.4 306 29 309 255 20.2 0.1 20.5 19.7 05/20/2005 12:10:00 3.7 1.5 6.8 0.7 3.5 1.6 6.8 0.4 2.7 1.8 7.2 0.4 300 38 289 255 20.3 0.2 20.8 19.7 05/20/2005 12:20:00 3.5 1.2 6.8 0.4 3.4 1.2 6.8 0.7 3 1.4 6.8 0.4 278 26 290 255 19.7 0 20 19.4 05/20/2005 12:30:00 3.7 1 5.7 0.7 3.6 1 6.8 1.1 2.6 1.2 5.7 0.4 284 26 290 255 20.1 0 20.5 19.7 05/20/2005 12:40:00 3.3 1.2 6.5 0.4 3.2 1.3 6.5 0.4 2.7 1.3 5.7 0.4 285 22 289 255 20 0.2 20.5 19.7 05/20/2005 12:50:00 3.5 1.1 6.1 0.7 3.4 1.2 6.1 0.4 2.7 1.2 5.3 0.4 299 24 304 255 21 0 21.7 20.5 05/20/2005 13:00:00 4.1 1.2 6.8 1.1 4 1.1 6.5 0.7 3.3 1.1 5.7 0.7 307 21 303 255 21 0 21.7 20.8 05/20/2005 13:10:00 3.8 1.4 8.8 0.7 3.6 1.4 8 0.4 2.8 1.5 6.5 0.4 316 26 330 255 21.5 0.1 22 21.1 05/20/2005 13:20:00 3.3 1.3 6.1 0.4 3.1 1.3 6.5 0.4 2.5 1.3 5.7 0.4 302 23 330 255 21.5 0 22 21.1 05/20/2005 13:30:00 3.9 1.3 6.8 0.7 3.8 1.5 6.8 0.4 3.2 1.5 6.5 0.4 304 24 306 255 21.4 0 22 21.1 05/20/2005 13:40:00 3.8 1.4 6.8 0.7 3.7 1.3 6.8 0.7 3 1.5 6.1 0.4 299 24 309 255 21 0.2 21.7 20.5 05/20/2005 13:50:00 4.3 1.4 7.2 0.7 4.3 1.4 7.2 0.7 3.5 1.6 6.8 0.4 291 19 312 255 20.5 0.2 21.1 20.3 05/20/2005 14:00:00 3.7 1.4 6.8 0.4 3.5 1.5 6.8 0.4 2.8 1.3 6.5 0.4 311 23 316 255 20.9 0.2 21.4 20.5 05/20/2005 14:10:00 3.8 1.1 6.8 0.4 3.7 1.1 6.8 1.1 3.2 1.2 6.5 0.4 286 20 293 255 20.9 0.3 21.4 20.3 05/20/2005 14:20:00 4 1.2 7.2 0.7 3.9 1.2 7.2 0.7 3.2 1.2 6.5 0.4 307 22 315 255 21 0.3 21.7 20.5 05/20/2005 14:30:00 3.7 1.2 6.8 0.7 3.6 1.2 6.8 1.5 2.7 1.3 6.1 0.4 304 22 300 255 21.4 0 21.7 21.1 05/20/2005 14:40:00 3.2 1.1 5.7 0.7 3.1 1.2 5.7 0.4 2.5 1.3 6.1 0.4 285 38 318 255 21.6 0 21.7 21.4 05/20/2005 14:50:00 3.1 1.5 7.2 0.4 3 1.5 6.8 0.4 2.4 1.5 6.5 0.4 265 36 311 255 21.5 0 21.7 21.1 05/20/2005 15:00:00 4.1 1.3 6.5 0.4 4 1.4 6.8 0.7 3.1 1.5 6.1 0.4 285 24 280 255 21.2 0 21.4 20.8 05/20/2005 15:10:00 4.6 1.4 8 1.9 4.5 1.5 8.4 1.1 3.5 1.5 8 0.4 292 22 313 255 21.1 0 21.4 21.1 05/20/2005 15:20:00 4.4 1.5 8 0.4 4.2 1.7 8.8 0.4 3.4 1.8 7.2 0.4 306 23 327 255 21.4 0.3 22 21.1 05/20/2005 15:30:00 4.1 1.4 7.2 0.7 4 1.4 7.6 0.4 2.9 1.5 6.8 0.4 282 33 284 255 21.3 0 21.7 21.1 05/20/2005 15:40:00 4.2 1.5 8 1.1 4.2 1.5 8.4 0.7 3.5 1.6 7.2 0.4 280 28 263 255 21 0 21.1 20.8 05/20/2005 15:50:00 5.1 1.2 8.4 1.5 5.1 1.3 8.4 1.5 4 1.5 8 1.1 288 20 294 255 20.7 0.1 21.1 20.5 05/20/2005 16:00:00 4.7 1.3 8.4 1.9 4.6 1.3 8.8 1.9 3.5 1.3 8 0.7 275 22 274 255 20.3 0.2 20.8 20 05/20/2005 16:10:00 5.4 1.1 8 2.3 5.2 1.2 7.6 2.3 4.2 1.5 7.6 0.7 288 18 302 255 19.7 0.2 20.5 19.4 05/20/2005 16:20:00 4.9 1.3 8.4 1.5 4.8 1.4 8.8 0.7 3.9 1.6 8 0.4 288 20 287 255 19.7 0 20 19.4 05/20/2005 16:30:00 4.6 1.4 8 1.5 4.6 1.4 8 0.7 3.6 1.5 7.6 0.4 290 22 307 255 19.4 0 19.4 19.4 05/20/2005 16:40:00 4.4 1.7 7.6 0.4 4.3 1.7 8 0.4 3.2 1.6 7.6 0.4 280 33 279 255 19.4 0 19.7 19.1 05/20/2005 16:50:00 4.6 1.5 8.8 0.7 4.5 1.5 8.4 1.1 3.6 1.4 7.2 0.4 287 29 283 255 19 0 19.4 18.8 05/20/2005 17:00:00 5 1.5 8 1.1 4.9 1.5 8.4 1.1 4.2 1.3 8 1.1 290 18 279 255 18.2 0.1 19.1 18 05/20/2005 17:10:00 4.6 1.5 8 0.4 4.5 1.5 7.6 0.4 3.6 1.7 7.6 0.4 287 20 284 255 18 0 18.2 17.7 05/20/2005 17:20:00 4.4 1.2 7.6 1.1 4.3 1.3 8 1.1 3.3 1.5 7.6 0.4 290 22 289 255 18.1 0 18.5 17.7 05/20/2005 17:30:00 5.7 1.3 8.8 2.6 5.6 1.5 9.1 2.3 4.7 1.5 8.4 0.4 287 17 274 255 17.7 0.2 18.2 17.1 05/20/2005 17:40:00 4.7 1.5 8 0.4 4.7 1.5 7.6 0.7 3.7 1.4 7.2 0.7 274 28 276 255 17.5 0.1 18 17.1 05/20/2005 17:50:00 4.6 1.4 8.4 1.5 4.5 1.5 8.4 0.4 3.6 1.6 8 0.4 272 23 255 255 17.5 0 18 17.4 05/20/2005 18:00:00 4.5 1.5 9.1 0.4 4.4 1.5 9.1 0.4 3.5 1.5 8 0.4 277 22 278 255 17.3 0.1 17.7 17.1 05/20/2005 18:10:00 4.9 1.4 8.8 1.5 4.8 1.5 9.1 1.5 3.8 1.5 9.1 0.4 280 21 281 255 17.3 0 17.7 17.1 05/20/2005 18:20:00 5.2 1.3 8 1.1 5.1 1.4 8 1.5 3.9 1.5 6.8 0.4 278 21 284 255 17.1 0 17.4 16.8 05/20/2005 18:30:00 4.2 1.3 8 1.5 4.1 1.4 8 1.1 3.1 1.4 7.2 0.4 272 21 273 255 16.8 0.1 17.1 16.8 05/20/2005 18:40:00 3.7 1 6.1 1.5 3.7 1.1 6.1 0.7 2.6 1.1 5.3 0.4 267 22 263 255 16.8 0 17.4 16.8 05/20/2005 18:50:00 2.4 1.3 5.7 0.4 2.2 1.4 5.7 0.4 1.7 1 5.3 0.4 266 32 263 255 16.8 0 17.4 16.8 05/20/2005 19:00:00 2.9 0.9 4.9 0.7 2.8 1 4.9 0.4 2.2 1 4.6 0.4 278 22 282 255 16.8 0 16.8 16.8 05/20/2005 19:10:00 3.6 1 5.3 0.7 3.5 1 5.3 0.7 2.9 1.2 5.7 0.4 297 18 277 255 16.4 0.1 16.8 16.3 05/20/2005 19:20:00 3.7 0.7 5.3 1.9 3.6 0.8 5.3 1.5 3 1 5.3 0.4 293 14 284 255 16 0 16.3 16 05/20/2005 19:30:00 3 0.7 4.9 1.1 2.8 0.7 4.6 1.1 2.1 0.8 4.6 0.4 303 15 305 255 15.8 0 16 15.7 05/20/2005 19:40:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 1.5 0.9 3.8 0.4 297 19 297 255 15.7 0 16 15.7 05/20/2005 19:50:00 1.9 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3.4 0.4 301 18 301 255 15.5 0 15.7 15.2 05/20/2005 20:00:00 2.2 0.8 4.2 0.4 2.1 0.8 3.4 0.4 1.5 0.8 3 0.4 306 15 345 255 15.2 0.1 15.7 15.2 05/20/2005 20:10:00 2.3 0.8 4.6 0.4 2.1 0.8 4.6 0.4 1.4 0.9 4.6 0.4 304 17 290 255 14.9 0 15.5 14.6 05/20/2005 20:20:00 2.7 0.9 4.6 0.4 2.6 1 4.2 0.4 1.9 1 4.2 0.4 296 17 312 255 14.6 0 14.9 14.6 05/20/2005 20:30:00 2.2 0.9 4.2 0.4 2 1 4.2 0.4 1.4 0.9 3.8 0.4 285 20 275 255 14.5 0 14.9 14.4 05/20/2005 20:40:00 2.1 0.6 3.4 0.4 1.9 0.7 3.4 0.4 1.4 0.8 3.4 0.4 292 16 298 255 14.2 0 14.6 14.1 05/20/2005 20:50:00 1.6 0.6 3.4 0.4 1.4 0.7 3 0.4 1 0.6 2.3 0.4 290 14 294 255 14 0 14.6 13.8 05/20/2005 21:00:00 1.2 0.7 3 0.4 0.9 0.8 3.4 0.4 0.7 0.6 3 0.4 286 15 284 255 13.8 0 14.4 13.5 05/20/2005 21:10:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 0.8 0.6 2.6 0.4 290 11 276 255 13.4 0.1 13.8 13 05/20/2005 21:20:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 278 22 297 255 13 0.1 13.5 12.7 05/20/2005 21:30:00 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 0.6 0.5 2.3 0.4 269 10 282 255 12.9 0.1 13.3 12.7 05/20/2005 21:40:00 1.1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.5 0.3 1.9 0.4 274 9 283 255 12.9 0 13.3 12.7 05/20/2005 21:50:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.4 0.2 1.9 0.4 283 11 292 255 12.6 0.1 13 12.5 05/20/2005 22:00:00 1.5 0.5 3 0.4 1.4 0.6 3 0.4 0.8 0.5 2.3 0.4 279 15 269 255 12.3 0 12.7 12.2 05/20/2005 22:10:00 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 0.6 0.5 2.6 0.4 280 20 308 255 12.3 0 12.7 12.2 05/20/2005 22:20:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 0.9 0.6 3 0.4 276 21 291 255 12.4 0.1 12.7 12.2 05/20/2005 22:30:00 1.7 0.6 3.4 0.4 1.6 0.7 3.4 0.4 0.8 0.6 3 0.4 259 17 280 255 12.5 0 12.7 12.5 05/20/2005 22:40:00 1.4 0.7 2.6 0.4 1.3 0.7 2.6 0.4 0.7 0.5 2.3 0.4 265 17 262 255 12.5 0.1 12.7 12.5 05/20/2005 22:50:00 1.7 0.7 3.8 0.4 1.5 0.7 3.8 0.4 0.9 0.7 3 0.4 252 8 250 255 12.4 0.1 12.7 12.5 05/20/2005 23:00:00 2.1 0.6 3.8 0.4 1.9 0.8 3.4 0.4 1 0.7 3 0.4 248 15 241 255 12.3 0 12.7 12.2 05/20/2005 23:10:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 0.7 0.5 2.6 0.4 250 13 246 255 12.3 0 12.7 12.2 05/20/2005 23:20:00 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.6 0.4 1.9 0.4 252 12 262 255 12.3 0 12.7 12.2 05/20/2005 23:30:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.2 2.3 0.4 246 13 253 255 12.2 0 12.5 11.9 05/20/2005 23:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 246 6 250 255 12 0 12.5 11.9 05/20/2005 23:50:00 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 245 5 252 255 11.7 0 12.2 11.7 05/21/2005 00:00:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 235 5 249 255 11.7 0 11.9 11.4 05/21/2005 00:10:00 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0 0.7 0.4 218 11 230 255 11.3 0 11.9 11.1 05/21/2005 00:20:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.7 0.4 212 9 224 255 10.9 0.1 11.4 10.6 05/21/2005 00:30:00 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.5 0.3 1.5 0.4 212 7 189 255 10.6 0 11.1 10.6 05/21/2005 00:40:00 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.4 0.1 1.1 0.4 214 5 218 255 10.5 0 10.9 10.6 05/21/2005 00:50:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 214 8 216 255 10.5 0 10.9 10.3 05/21/2005 01:00:00 0.6 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.4 0 0.4 0.4 203 0 206 255 10.3 0 10.6 10.3 05/21/2005 01:10:00 1.9 0.6 3.4 0.4 1.8 0.7 3.4 0.4 0.7 0.5 2.6 0.4 196 13 212 255 10.3 0 10.3 10.3 05/21/2005 01:20:00 1.7 0.5 3.4 0.4 1.6 0.5 3 0.4 0.8 0.5 2.3 0.4 196 10 183 255 10.2 0 10.3 10.3 05/21/2005 01:30:00 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 0.6 0.4 1.9 0.4 196 9 196 255 10.2 0 10.3 10.1 05/21/2005 01:40:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.6 0.5 3 0.4 183 14 200 255 10.2 0 10.3 10.1 05/21/2005 01:50:00 1.6 0.6 3.4 0.4 1.6 0.6 3.4 0.4 0.7 0.5 2.6 0.4 185 14 174 255 10.2 0 10.3 10.3 05/21/2005 02:00:00 1.8 0.6 3.4 0.4 1.8 0.6 3.8 0.4 1 0.6 2.6 0.4 189 13 186 255 10.2 0 10.3 10.1 05/21/2005 02:10:00 1.4 0.5 3 0.4 1.5 0.6 3 0.4 0.7 0.5 2.6 0.4 185 13 175 255 10 0 10.1 10.1 05/21/2005 02:20:00 1.3 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.6 0.4 1.9 0.4 186 11 181 255 10 0 10.1 9.8 05/21/2005 02:30:00 1.2 0.5 2.3 0.4 1.4 0.5 2.6 0.4 0.6 0.4 1.9 0.4 184 9 186 255 9.9 0 10.1 9.8 05/21/2005 02:40:00 1.4 0.4 2.6 0.4 1.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 184 10 182 255 9.8 0 9.8 9.8 05/21/2005 02:50:00 1.4 0.5 3 0.4 1.6 0.6 3 0.4 0.6 0.4 2.3 0.4 178 9 177 255 9.8 0 9.8 9.8 05/21/2005 03:00:00 1 0.4 1.9 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 175 11 169 255 9.8 0 9.8 9.6 05/21/2005 03:10:00 1.1 0.4 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 167 8 168 255 9.7 0 9.8 9.6 05/21/2005 03:20:00 1.6 0.3 2.6 0.7 1.4 0.4 2.3 0.4 0.6 0.4 1.9 0.4 158 7 160 255 9.6 0 9.8 9.6 05/21/2005 03:30:00 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 153 3 160 255 9.6 0 9.8 9.6 05/21/2005 03:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 143 255 9.5 0 9.6 9.6 05/21/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 140 20 255 255 9.5 0 9.6 9.6 05/21/2005 04:00:00 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 9 2 12 255 9.5 0 9.6 9.6 05/21/2005 04:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 8 255 9.5 0 9.6 9.6 05/21/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 255 255 9.5 0 9.6 9.6 05/21/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 255 255 9.5 0 9.6 9.3 05/21/2005 04:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 17 326 255 9.5 0 9.6 9.6 05/21/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 255 255 9.5 0 9.6 9.6 05/21/2005 05:00:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 344 15 326 255 9.5 0 9.6 9.6 05/21/2005 05:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 6 0 255 9.5 0 9.6 9.6 05/21/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 9.5 0 9.6 9.6 05/21/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 9.5 0 9.6 9.6 05/21/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 53 255 255 9.6 0 9.6 9.6 05/21/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 0 255 255 9.6 0 9.8 9.6 05/21/2005 06:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 74 17 68 255 9.8 0 9.8 9.6 05/21/2005 06:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 57 8 49 255 9.8 0 9.8 9.8 05/21/2005 06:20:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 0.6 0.4 1.9 0.4 29 17 40 255 10 0 10.1 9.8 05/21/2005 06:30:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 11 11 11 255 10 0 10.1 9.8 05/21/2005 06:40:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.3 1.9 0.4 16 14 359 255 10 0 10.1 9.8 05/21/2005 06:50:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 12 9 19 255 10 0 10.1 9.8 05/21/2005 07:00:00 1.3 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 24 18 16 255 10 0 10.1 9.8 05/21/2005 07:10:00 1.6 0.4 2.6 0.4 1.3 0.5 2.3 0.4 0.5 0.3 1.9 0.4 10 15 20 255 10 0 10.1 9.8 05/21/2005 07:20:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 39 15 17 255 10 0 10.1 9.8 05/21/2005 07:30:00 1.8 0.6 3 0.4 1.5 0.7 3 0.4 1.2 0.7 3 0.4 50 12 44 255 9.9 0 10.1 9.8 05/21/2005 07:40:00 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1 0.5 2.3 0.4 48 15 51 255 9.8 0 9.8 9.8 05/21/2005 07:50:00 1.4 0.4 2.3 0.4 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 48 18 19 255 9.9 0 10.1 9.8 05/21/2005 08:00:00 1.7 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 54 10 60 255 9.8 0 10.1 9.8 05/21/2005 08:10:00 1.9 0.6 3 0.4 1.8 0.7 3 0.4 1.4 0.7 2.6 0.4 50 13 52 255 9.9 0 10.1 9.8 05/21/2005 08:20:00 2.2 0.6 3 0.4 2.1 0.7 3.4 0.4 1.8 0.5 3 0.4 46 10 40 255 9.8 0 9.8 9.6 05/21/2005 08:30:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 1.4 0.6 2.6 0.4 31 8 35 255 9.7 0 9.8 9.6 05/21/2005 08:40:00 2.2 0.3 3 1.5 2 0.4 2.6 1.1 1.5 0.5 2.6 0.4 46 12 53 255 9.7 0 9.8 9.6 05/21/2005 08:50:00 1.7 0.5 3 0.4 1.5 0.5 3 0.4 1.1 0.5 2.3 0.4 52 9 71 255 9.7 0 9.8 9.6 05/21/2005 09:00:00 1.2 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 41 14 54 255 9.7 0 9.8 9.6 05/21/2005 09:10:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 40 15 31 255 9.9 0 10.1 9.8 05/21/2005 09:20:00 0.9 0.6 2.6 0.4 0.7 0.6 2.3 0.4 0.7 0.6 2.6 0.4 46 17 39 255 10.1 0 10.3 9.8 05/21/2005 09:30:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 55 13 64 255 10.2 0 10.3 10.1 05/21/2005 09:40:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 29 22 34 255 10.5 0 10.6 10.3 05/21/2005 09:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 4 12 358 255 10.6 0 10.9 10.6 05/21/2005 10:00:00 0.6 0.3 1.5 0.4 0.4 0.3 1.5 0.4 0.5 0.3 1.9 0.4 24 8 27 255 10.6 0 10.9 10.6 05/21/2005 10:10:00 0.4 0.2 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.4 0.4 34 4 15 255 10.8 0 11.1 10.6 05/21/2005 10:20:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 13 30 14 255 11.1 0 11.4 11.1 05/21/2005 10:30:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 47 17 27 255 11.1 0 11.4 11.1 05/21/2005 10:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 28 52 255 11.2 0 11.4 11.1 05/21/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 27 255 255 11.4 0 11.7 11.4 05/21/2005 11:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 27 6 255 11.3 0 11.7 11.4 05/21/2005 11:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 17 21 21 255 11.6 0 12.2 11.4 05/21/2005 11:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 7 8 356 255 11.7 0 12.2 11.7 05/21/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 49 255 255 11.8 0 11.9 11.7 05/21/2005 11:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 202 7 211 255 11.5 0 11.9 11.1 05/21/2005 11:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 210 16 202 255 11 0 11.1 10.9 05/21/2005 12:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 22 240 255 10.9 0 11.4 10.6 05/21/2005 12:10:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.4 0 0.7 0.4 266 36 220 255 11.1 0 11.7 11.1 05/21/2005 12:20:00 1.3 0.6 2.6 0.4 1.3 0.7 2.6 0.4 0.6 0.4 2.3 0.4 226 22 211 255 11.1 0 11.1 11.1 05/21/2005 12:30:00 2 0.7 4.2 0.4 1.8 0.7 3.8 0.4 1.2 0.8 3.4 0.4 240 17 212 255 10.9 0.1 11.1 10.9 05/21/2005 12:40:00 0.8 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.3 2.3 0.4 255 24 254 255 10.9 0 11.4 10.9 05/21/2005 12:50:00 1.4 0.7 3 0.4 1.3 0.7 3.4 0.4 0.8 0.6 2.6 0.4 247 14 246 255 11.1 0 11.7 10.9 05/21/2005 13:00:00 0.7 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 237 13 225 255 11.3 0.1 11.7 11.1 05/21/2005 13:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 246 20 255 255 11.5 0 11.9 11.4 05/21/2005 13:20:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 276 16 265 255 11.3 0 11.9 11.1 05/21/2005 13:30:00 1.3 0.6 2.6 0.4 1.1 0.7 2.6 0.4 0.7 0.6 2.3 0.4 279 19 276 255 11.1 0 11.7 10.9 05/21/2005 13:40:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 276 30 257 255 11.2 0 11.7 11.1 05/21/2005 13:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 310 64 283 255 11.7 0.1 12.2 11.4 05/21/2005 14:00:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 292 27 311 255 11.7 0 12.2 11.7 05/21/2005 14:10:00 1.1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.5 1.9 0.4 302 18 323 255 11.8 0.1 12.2 11.7 05/21/2005 14:20:00 1.1 0.5 2.3 0.4 1 0.6 2.3 0.4 0.5 0.2 1.5 0.4 293 20 298 255 11.9 0 12.5 11.7 05/21/2005 14:30:00 1.2 0.8 3 0.4 1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 283 22 283 255 11.8 0 12.2 11.7 05/21/2005 14:40:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 302 19 308 255 11.9 0.1 12.5 11.7 05/21/2005 14:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 246 22 274 255 11.7 0.1 12.2 11.7 05/21/2005 15:00:00 1.9 0.5 2.6 0.4 1.8 0.5 2.6 0.4 1.4 0.5 2.6 0.4 212 12 185 255 11.7 0 11.9 11.7 05/21/2005 15:10:00 1.4 0.6 3 0.4 1.2 0.7 2.6 0.4 0.9 0.5 1.9 0.4 208 13 231 255 11.7 0 11.9 11.7 05/21/2005 15:20:00 1.8 0.7 3 0.4 1.8 0.7 3 0.4 1.4 0.7 3 0.4 218 20 243 255 12.1 0 12.5 11.9 05/21/2005 15:30:00 1.3 0.7 3 0.4 1.2 0.8 3.4 0.4 1.1 0.6 2.6 0.4 217 35 218 255 12.1 0 12.5 11.9 05/21/2005 15:40:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 204 29 195 255 12 0 12.5 11.9 05/21/2005 15:50:00 2.2 0.8 3.8 0.4 2.2 0.8 3.4 0.4 1.8 0.8 3.8 0.4 221 15 212 255 12.2 0 12.5 11.9 05/21/2005 16:00:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 219 20 202 255 12.3 0 12.7 12.2 05/21/2005 16:10:00 1.3 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.9 0.6 2.3 0.4 231 15 252 255 12.7 0 13 12.5 05/21/2005 16:20:00 1.1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.8 0.6 2.6 0.4 228 32 256 255 12.7 0 13.3 12.5 05/21/2005 16:30:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 234 21 248 255 12.6 0.1 13 12.5 05/21/2005 16:40:00 1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 1 0.8 3 0.4 262 38 241 255 12.9 0 13.3 12.7 05/21/2005 16:50:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.3 1.9 0.4 229 43 217 255 12.9 0 13.3 12.7 05/21/2005 17:00:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 234 22 238 255 13.3 0 13.8 12.7 05/21/2005 17:10:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 282 45 237 255 13.2 0.2 13.8 12.7 05/21/2005 17:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 211 11 227 255 12.9 0.1 13.3 12.7 05/21/2005 17:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 205 36 200 255 13 0.1 13.3 12.7 05/21/2005 17:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.5 1.9 0.4 212 38 214 255 12.9 0 13.3 12.7 05/21/2005 17:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 221 36 266 255 12.9 0 13.3 12.7 05/21/2005 18:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 208 35 255 255 12.8 0 13.3 12.7 05/21/2005 18:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 270 20 280 255 12.8 0 13 12.7 05/21/2005 18:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 286 11 275 255 12.8 0 13.3 12.7 05/21/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 255 255 12.6 0 12.7 12.5 05/21/2005 18:40:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 295 11 304 255 12.5 0 13 12.5 05/21/2005 18:50:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 300 12 283 255 12.6 0 13 12.5 05/21/2005 19:00:00 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 304 10 302 255 12.6 0 13 12.5 05/21/2005 19:10:00 1.2 0.5 2.3 0.4 1 0.6 1.9 0.4 0.8 0.5 1.9 0.4 295 8 289 255 12.5 0.1 13 12.2 05/21/2005 19:20:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 304 10 306 255 12.4 0 12.7 12.2 05/21/2005 19:30:00 1.8 0.4 3 0.7 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 290 7 292 255 12.2 0 12.7 11.9 05/21/2005 19:40:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.9 0.6 2.6 0.4 292 12 305 255 12 0 12.2 11.9 05/21/2005 19:50:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 290 11 280 255 12 0 12.5 11.9 05/21/2005 20:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 300 3 305 255 12 0 12.2 11.9 05/21/2005 20:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 11.9 0 12.2 11.7 05/21/2005 20:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 11.7 0 11.9 11.7 05/21/2005 20:30:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 301 0 301 255 11.5 0.1 11.7 11.4 05/21/2005 20:40:00 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 301 2 307 255 11.2 0 11.7 11.1 05/21/2005 20:50:00 1.2 0.3 2.3 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 303 6 296 255 11.1 0 11.1 10.9 05/21/2005 21:00:00 0.9 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 303 1 303 255 10.9 0 11.1 10.9 05/21/2005 21:10:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 298 6 300 255 10.7 0.1 11.1 10.6 05/21/2005 21:20:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 301 0 301 255 10.6 0 10.9 10.6 05/21/2005 21:30:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 301 0 301 255 10.5 0 10.6 10.3 05/21/2005 21:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 10.3 0 10.6 10.3 05/21/2005 21:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 10.2 0 10.3 10.1 05/21/2005 22:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 289 4 301 255 10 0 10.1 9.8 05/21/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 0 255 255 9.8 0 9.8 9.6 05/21/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 3 255 255 9.6 0 9.8 9.6 05/21/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 9.5 0 9.6 9.3 05/21/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 9.4 0 9.6 9.3 05/21/2005 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 295 255 9.2 0 9.3 9 05/21/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 9.2 0 9.3 9 05/21/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 9 0 9.3 9 05/21/2005 23:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 290 8 277 255 9 0 9 9 05/21/2005 23:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 275 255 9 0 9.3 9 05/21/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.1 0 9.3 9 05/21/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9 05/22/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9 05/22/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.3 0 9.3 9.3 05/22/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.4 0 9.3 9.3 05/22/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.4 0 9.3 9.3 05/22/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.4 0 9.6 9.3 05/22/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.3 0 9.3 9 05/22/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9.3 05/22/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9.3 05/22/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9.3 05/22/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9 05/22/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9 05/22/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9 05/22/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9.2 0 9.3 9 05/22/2005 02:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 275 255 9.1 0 9.3 9 05/22/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 255 255 9 0 9 9 05/22/2005 02:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 8 275 255 9 0 9 9 05/22/2005 02:40:00 0.5 0.2 1.1 0.4 0.4 0 1.1 0.4 0.4 0 0.4 0.4 256 0 256 255 8.9 0 9 9 05/22/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 0 255 255 8.9 0 9 9 05/22/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 0 255 255 8.9 0 9 9 05/22/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 0 255 255 8.9 0 9 8.8 05/22/2005 03:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 4 256 255 8.9 0 9 8.8 05/22/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 267 0 255 255 8.9 0 9 8.8 05/22/2005 03:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 267 1 264 255 8.9 0 9 9 05/22/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9 0 9 9 05/22/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9 0 9 9 05/22/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9 0 9.3 9 05/22/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9.1 0 9.3 9 05/22/2005 04:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 264 255 9.1 0 9.3 9 05/22/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9.2 0 9.3 9 05/22/2005 04:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 264 255 9.2 0 9.3 9.3 05/22/2005 05:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 264 255 9.3 0 9.3 9.3 05/22/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9.4 0 9.6 9.3 05/22/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9.5 0 9.6 9.6 05/22/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 255 255 9.5 0 9.6 9.6 05/22/2005 05:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 261 2 259 255 9.5 0 9.6 9.6 05/22/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 259 0 259 255 9.5 0 9.6 9.6 05/22/2005 06:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 263 7 270 255 9.6 0 9.6 9.6 05/22/2005 06:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 267 1 268 255 9.6 0 9.8 9.6 05/22/2005 06:20:00 1 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0.1 1.1 0.4 262 6 259 255 9.6 0 9.8 9.6 05/22/2005 06:30:00 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 282 12 261 255 9.7 0 9.8 9.6 05/22/2005 06:40:00 0.7 0.4 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0 0.7 0.4 278 15 292 255 9.8 0 9.8 9.6 05/22/2005 06:50:00 0.8 0.4 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0 0.7 0.4 271 14 255 255 9.7 0 9.8 9.6 05/22/2005 07:00:00 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 0.5 0.2 1.5 0.4 275 16 255 255 9.7 0 9.8 9.6 05/22/2005 07:10:00 1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.5 0.4 278 15 268 255 9.8 0 9.8 9.6 05/22/2005 07:20:00 1.6 0.5 3 0.4 1.3 0.6 2.6 0.4 0.5 0.2 1.5 0.4 277 10 280 255 9.9 0 10.1 9.8 05/22/2005 07:30:00 1.8 0.8 3.4 0.4 1.7 0.8 3.4 0.4 0.6 0.5 2.3 0.4 279 15 240 255 10 0 10.1 9.8 05/22/2005 07:40:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.1 0.7 2.6 0.4 285 16 298 255 10 0 10.1 9.8 05/22/2005 07:50:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 293 19 305 255 10.1 0 10.3 9.8 05/22/2005 08:00:00 1.6 0.7 3 0.4 1.3 0.8 3 0.4 0.9 0.7 2.6 0.4 283 17 310 255 10.1 0 10.3 10.1 05/22/2005 08:10:00 1.9 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.1 0.7 3 0.4 267 21 269 255 10.2 0 10.3 10.1 05/22/2005 08:20:00 1.8 0.8 4.2 0.4 1.6 0.8 3.8 0.4 0.9 0.7 2.6 0.4 268 20 255 255 10.2 0 10.3 10.1 05/22/2005 08:30:00 1.7 0.9 3.8 0.4 1.6 0.9 3.4 0.4 0.9 0.7 3 0.4 277 19 277 255 10.2 0 10.3 10.1 05/22/2005 08:40:00 1.9 0.9 3.8 0.4 1.7 0.9 3.8 0.4 1.2 0.8 3.4 0.4 265 22 252 255 10.2 0 10.3 10.3 05/22/2005 08:50:00 1.6 0.7 3.8 0.4 1.3 0.8 4.2 0.4 0.8 0.6 2.6 0.4 272 21 255 255 10.4 0 10.6 10.3 05/22/2005 09:00:00 2.4 0.8 3.8 0.4 2.2 0.8 3.8 0.4 1.4 0.8 3.4 0.4 267 19 261 255 10.5 0 10.6 10.6 05/22/2005 09:10:00 1.3 0.7 3.4 0.4 1.1 0.8 3.4 0.4 0.8 0.8 3.4 0.4 286 35 255 255 10.8 0.1 11.1 10.6 05/22/2005 09:20:00 2.3 0.7 3.8 0.4 2.3 0.8 3.8 0.4 1.5 0.8 3.4 0.4 262 22 253 255 11.3 0 11.4 11.1 05/22/2005 09:30:00 1.6 1 3.8 0.4 1.4 1 3.8 0.4 1 0.9 3.4 0.4 268 43 258 255 11.4 0 11.7 11.1 05/22/2005 09:40:00 2.5 0.7 4.2 0.7 2.4 0.8 4.2 0.7 1.7 0.8 3.4 0.4 268 24 264 255 11.5 0.1 11.9 11.4 05/22/2005 09:50:00 2.6 0.7 4.2 1.1 2.4 0.9 4.2 0.4 2.1 0.8 3.8 0.4 295 16 283 255 11.7 0 11.9 11.7 05/22/2005 10:00:00 2.1 0.8 4.2 0.4 1.9 0.8 3.8 0.4 1.5 0.8 3.4 0.4 283 26 279 255 12.1 0.1 12.7 11.7 05/22/2005 10:10:00 1.8 0.9 4.2 0.4 1.5 1 4.2 0.4 1.2 0.9 3.4 0.4 284 23 299 255 12.7 0.2 13.3 12.2 05/22/2005 10:20:00 2.5 0.8 4.2 0.7 2.4 0.9 4.2 0.4 1.9 0.9 4.2 0.4 291 22 309 255 12.5 0.2 13.3 12.2 05/22/2005 10:30:00 2.4 1.1 4.6 0.4 2.3 1.1 4.2 0.4 1.8 1 4.2 0.4 274 36 308 255 12.5 0.2 12.7 12.2 05/22/2005 10:40:00 2.8 0.6 4.2 1.5 2.7 0.6 4.6 0.7 2 0.8 3.8 0.4 269 15 260 255 12.1 0 12.5 11.9 05/22/2005 10:50:00 2.5 0.8 4.2 0.4 2.4 0.9 4.6 0.4 1.8 0.8 3.8 0.4 267 32 257 255 12.3 0.1 12.7 12.2 05/22/2005 11:00:00 2.3 0.9 4.2 0.4 2.1 1 4.2 0.4 1.8 0.9 4.2 0.4 279 24 299 255 12.7 0.2 13.3 12.5 05/22/2005 11:10:00 2.7 1.1 4.6 0.4 2.7 1.1 5.3 0.4 2 1 4.6 0.4 251 39 247 255 12.7 0 13 12.5 05/22/2005 11:20:00 2.5 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.9 0.9 4.2 0.4 265 24 250 255 13.2 0.2 13.8 12.7 05/22/2005 11:30:00 2.6 0.8 4.6 0.7 2.5 0.9 4.2 0.4 2.2 0.9 4.2 0.4 269 20 293 255 12.9 0.1 13.5 12.7 05/22/2005 11:40:00 2.4 1.3 5.7 0.4 2.3 1.3 5.7 0.4 2 1 4.6 0.4 253 47 277 255 13.3 0.1 13.8 12.7 05/22/2005 11:50:00 2.7 0.8 4.6 0.4 2.5 1 4.6 0.4 1.8 0.9 3.8 0.4 247 28 255 255 12.5 0.2 13 12.2 05/22/2005 12:00:00 2.2 0.7 3.4 0.7 2.1 0.8 3.8 0.4 1.4 0.8 3.4 0.4 240 20 246 255 12.3 0 12.5 12.2 05/22/2005 12:10:00 2.3 0.9 4.6 0.4 2.2 1 4.6 0.4 1.5 1 4.2 0.4 246 17 229 255 12.3 0 12.7 12.2 05/22/2005 12:20:00 3 0.9 4.9 0.7 2.8 1 4.9 0.4 1.9 1 4.6 0.4 240 24 249 255 12.5 0 13 12.2 05/22/2005 12:30:00 2.7 0.9 4.6 0.7 2.6 0.9 4.9 0.4 1.8 1 4.2 0.4 240 19 245 255 12.8 0.1 13.3 12.5 05/22/2005 12:40:00 3.1 0.8 4.9 1.1 2.9 0.9 4.6 0.7 2.3 1 4.2 0.4 254 22 267 255 13 0.1 13.5 12.7 05/22/2005 12:50:00 1.6 1 3.8 0.4 1.4 1 3.8 0.4 1.1 0.8 3.8 0.4 247 32 243 255 13.3 0.2 13.8 12.7 05/22/2005 13:00:00 2.3 1 4.6 0.4 2.1 1 4.6 0.4 1.9 1 4.6 0.4 244 28 260 255 13.9 0 14.6 13.8 05/22/2005 13:10:00 2.2 0.7 4.2 0.7 2 0.8 4.2 0.4 1.8 0.8 4.2 0.4 248 21 252 255 13.9 0.1 14.6 13.5 05/22/2005 13:20:00 2.2 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.8 0.8 4.2 0.4 264 32 246 255 14.3 0 14.6 14.1 05/22/2005 13:30:00 2.2 0.9 4.2 0.4 2 1 3.8 0.4 1.6 1 4.2 0.4 267 33 276 255 14.5 0 14.9 14.4 05/22/2005 13:40:00 1.7 0.9 4.2 0.4 1.5 0.9 4.2 0.4 1.2 0.8 3.4 0.4 241 36 262 255 14.6 0 15.2 14.4 05/22/2005 13:50:00 2 0.8 3.8 0.4 1.8 0.9 3.8 0.4 1.5 0.8 4.2 0.4 266 22 253 255 14.6 0 15.2 14.4 05/22/2005 14:00:00 2.3 0.9 4.2 0.4 2 1 4.2 0.4 1.6 1 4.6 0.4 251 43 211 255 14.5 0.1 15.2 14.4 05/22/2005 14:10:00 2.7 1.1 4.9 0.4 2.5 1.2 4.6 0.4 2.3 1 4.9 0.4 277 21 294 255 14.6 0.1 15.2 14.4 05/22/2005 14:20:00 1.7 1 4.2 0.4 1.5 1 4.2 0.4 1.3 0.9 3.8 0.4 264 29 262 255 14.3 0 14.6 14.1 05/22/2005 14:30:00 2.1 0.8 4.2 0.4 2 0.9 4.2 0.4 1.7 0.8 3.4 0.4 288 21 268 255 15.6 0.3 16.3 14.6 05/22/2005 14:40:00 2.9 1.3 5.7 0.4 2.7 1.3 5.7 0.4 1.9 1.1 4.6 0.4 306 32 316 255 16.4 0.2 16.8 16 05/22/2005 14:50:00 2.3 0.7 4.2 0.7 2.2 0.8 3.8 0.4 1.8 0.8 3.8 0.4 273 29 255 255 15.9 0.1 16.6 15.7 05/22/2005 15:00:00 2.3 1.1 5.7 0.4 2.2 1.1 5.3 0.4 1.7 1 4.2 0.4 268 32 286 255 15.5 0.2 16 15.2 05/22/2005 15:10:00 2.6 1.1 5.7 0.4 2.5 1.2 5.7 0.4 2 1 4.6 0.4 269 23 255 255 15 0 15.5 14.9 05/22/2005 15:20:00 2.3 0.8 4.6 0.4 2.1 0.9 3.8 0.4 1.7 0.9 4.2 0.4 280 33 290 255 15.1 0 15.5 14.9 05/22/2005 15:30:00 2.6 1.2 4.9 0.4 2.5 1.2 4.9 0.4 2 1.1 4.9 0.4 256 30 219 255 15.5 0.2 16 15.2 05/22/2005 15:40:00 2.9 0.9 4.6 0.7 2.7 0.9 4.6 0.4 2.4 1 4.6 0.4 290 20 317 255 15.3 0.1 15.7 15.2 05/22/2005 15:50:00 2.9 0.7 4.6 1.1 2.8 0.8 4.6 0.4 2.4 0.7 4.2 0.4 284 22 314 255 15.4 0.1 15.7 15.2 05/22/2005 16:00:00 2.4 0.9 4.9 0.4 2.3 1 5.3 0.4 1.9 1 4.9 0.4 288 21 300 255 15 0 15.2 14.9 05/22/2005 16:10:00 2 1.1 5.3 0.4 1.8 1.1 4.6 0.4 1.4 1.1 4.2 0.4 303 29 301 255 15 0 15.5 14.9 05/22/2005 16:20:00 2.3 0.8 4.2 0.7 2.1 0.9 4.2 0.4 1.8 1 3.8 0.4 297 20 315 255 15.2 0 15.7 15.2 05/22/2005 16:30:00 2.1 0.8 3.8 0.4 1.8 0.9 3.4 0.4 1.7 0.8 3.4 0.4 302 23 322 255 15.3 0 15.7 15.2 05/22/2005 16:40:00 2.4 1 4.6 0.4 2.2 1 4.2 0.4 1.8 1 4.9 0.4 313 22 317 255 15.5 0 15.7 15.2 05/22/2005 16:50:00 2.7 1 4.6 0.4 2.5 1.1 4.6 0.4 2.1 1 4.2 0.4 304 17 300 255 15.3 0.2 15.7 14.9 05/22/2005 17:00:00 2.8 0.8 4.9 1.1 2.6 1 4.9 0.4 2.1 1 4.6 0.4 320 17 305 255 14.8 0 15.2 14.6 05/22/2005 17:10:00 2.1 0.8 4.9 0.4 1.8 0.8 4.6 0.4 1.3 0.8 3.8 0.4 328 18 346 255 14.7 0 15.2 14.6 05/22/2005 17:20:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 1 0.6 2.3 0.4 311 27 265 255 14.8 0 15.2 14.6 05/22/2005 17:30:00 1.9 0.6 3 0.7 1.4 0.6 3 0.4 1.3 0.6 3 0.4 339 11 324 255 14.9 0 15.5 14.9 05/22/2005 17:40:00 0.7 0.5 2.6 0.4 0.6 0.5 2.3 0.4 0.4 0.2 1.5 0.4 346 9 353 255 14.7 0 15.5 14.6 05/22/2005 17:50:00 1.4 1 3 0.4 1.2 1 3 0.4 0.9 0.7 2.6 0.4 11 14 6 255 14.6 0 15.2 14.6 05/22/2005 18:00:00 0.9 0.6 2.3 0.4 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 89 45 157 255 14.1 0.2 14.9 13.8 05/22/2005 18:10:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.8 2.6 0.4 28 12 37 255 13.9 0 14.6 13.8 05/22/2005 18:20:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.5 0.4 1.9 0.4 18 21 38 255 13.9 0 14.6 13.5 05/22/2005 18:30:00 2.2 0.7 3.8 0.4 2 0.7 3.8 0.4 1.7 0.7 3 0.4 109 12 111 255 13.5 0.2 13.8 13 05/22/2005 18:40:00 1.2 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 90 20 122 255 13.1 0 13.5 13 05/22/2005 18:50:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 73 13 61 255 13.1 0 13.5 13 05/22/2005 19:00:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 108 6 110 255 13 0.1 13.5 12.7 05/22/2005 19:10:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1 0.6 2.6 0.4 128 14 138 255 12.9 0 13.3 12.7 05/22/2005 19:20:00 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 161 20 141 255 12.6 0 12.7 12.5 05/22/2005 19:30:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 215 24 197 255 12.4 0 12.7 12.2 05/22/2005 19:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 113 13 109 255 12.4 0 12.5 12.2 05/22/2005 19:50:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1 0.4 1.9 0.4 142 9 136 255 12.4 0 12.7 12.2 05/22/2005 20:00:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 116 18 146 255 12.4 0 12.5 12.2 05/22/2005 20:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 90 38 60 255 12.3 0 12.7 12.2 05/22/2005 20:20:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 146 15 175 255 12.3 0 12.7 12.2 05/22/2005 20:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 121 0 121 255 12.3 0 12.7 12.2 05/22/2005 20:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 0 121 255 12.3 0 12.7 11.9 05/22/2005 20:50:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 119 4 121 255 12 0.1 12.5 11.7 05/22/2005 21:00:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 90 11 91 255 11.7 0 12.2 11.4 05/22/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 79 0 255 255 11.3 0.1 11.9 11.1 05/22/2005 21:20:00 0.9 0.6 1.9 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 127 36 160 255 10.9 0.1 11.7 10.6 05/22/2005 21:30:00 1.3 0.2 1.9 0.4 1.1 0.2 1.5 0.4 1 0.4 1.5 0.4 165 4 160 255 10.6 0 10.9 10.6 05/22/2005 21:40:00 0.9 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 126 21 159 255 10.3 0 10.6 10.1 05/22/2005 21:50:00 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 101 0 101 255 10 0 10.1 9.8 05/22/2005 22:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 0 101 255 9.6 0 9.8 9.6 05/22/2005 22:10:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 14 101 255 9.4 0 9.6 9 05/22/2005 22:20:00 1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 73 0 73 255 9 0 9.3 9 05/22/2005 22:30:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 104 30 128 255 8.9 0 9 8.8 05/22/2005 22:40:00 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 117 17 122 255 8.6 0 8.8 8.5 05/22/2005 22:50:00 1.5 0.4 2.6 0.4 1.3 0.5 2.3 0.4 0.5 0.3 1.5 0.4 103 6 74 255 8.4 0 8.5 8.5 05/22/2005 23:00:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 0.4 0.2 1.1 0.4 82 9 77 255 8.2 0 8.5 8.3 05/22/2005 23:10:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 0.9 0.3 1.9 0.4 92 4 92 255 8.1 0 8.3 8 05/22/2005 23:20:00 1.8 0.3 2.6 1.1 1.6 0.4 2.6 0.7 0.5 0.3 1.5 0.4 102 8 93 255 7.9 0 8 7.8 05/22/2005 23:30:00 1.6 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.7 0.4 1.9 0.4 125 14 142 255 7.8 0 8 7.8 05/22/2005 23:40:00 2.3 0.4 3.4 1.5 2.1 0.4 3 1.1 0.8 0.4 2.3 0.4 101 10 101 255 7.6 0 7.8 7.5 05/22/2005 23:50:00 1.5 0.4 2.3 0.7 1.3 0.4 2.3 0.4 0.4 0 0.7 0.4 85 7 92 255 7.4 0 7.5 7.3 05/23/2005 00:00:00 1.8 0.5 3.4 0.7 1.6 0.5 3.4 0.4 0.5 0.3 1.5 0.4 88 7 85 255 7.3 0.1 8 7 05/23/2005 00:10:00 1.5 0.4 2.6 0.4 1.3 0.4 2.6 0.4 0.4 0.1 1.1 0.4 98 11 70 255 7.1 0 7.3 7 05/23/2005 00:20:00 1.8 0.3 2.6 1.1 1.6 0.3 2.3 1.1 0.4 0.1 1.1 0.4 93 9 101 255 7 0 7.3 7 05/23/2005 00:30:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 125 20 89 255 6.9 0 7 6.7 05/23/2005 00:40:00 0.9 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 129 23 141 255 6.7 0 7 6.7 05/23/2005 00:50:00 2 0.7 3 0.4 1.8 0.8 3 0.4 1.4 0.5 2.6 0.4 145 7 146 255 6.6 0 6.7 6.5 05/23/2005 01:00:00 2.5 0.4 3.4 1.1 2.5 0.5 3.4 0.7 1.4 0.6 2.6 0.4 145 9 153 255 6.4 0 6.7 6.2 05/23/2005 01:10:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.7 0.5 2.6 0.4 129 10 142 255 6.7 0.2 7.3 6.2 05/23/2005 01:20:00 1.9 0.5 3 0.7 1.7 0.6 3 0.4 0.9 0.5 2.6 0.4 119 10 136 255 7.1 0 7.3 7 05/23/2005 01:30:00 2.1 0.5 3 0.7 1.9 0.5 3 0.4 0.9 0.5 2.3 0.4 117 9 115 255 6.9 0 7 6.7 05/23/2005 01:40:00 1.6 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.6 0.4 2.3 0.4 119 12 117 255 6.8 0 7 6.7 05/23/2005 01:50:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 127 13 122 255 6.7 0 7 6.7 05/23/2005 02:00:00 1.8 0.6 3.4 0.4 1.5 0.7 3 0.4 0.7 0.4 1.9 0.4 110 12 112 255 6.9 0 7.3 6.7 05/23/2005 02:10:00 2.6 0.5 3.8 0.7 2.5 0.5 3.8 0.4 1.5 0.7 3 0.4 108 11 101 255 7.1 0 7.3 7 05/23/2005 02:20:00 2.7 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.5 0.7 3 0.4 112 10 116 255 7 0 7.3 7 05/23/2005 02:30:00 2.5 0.5 3.4 0.7 2.3 0.5 3.4 0.4 1.3 0.7 3 0.4 112 13 109 255 7.1 0 7.3 7 05/23/2005 02:40:00 1.9 0.5 3 0.7 1.7 0.6 3.4 0.4 0.5 0.3 1.5 0.4 113 11 124 255 6.9 0 7 7 05/23/2005 02:50:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 124 14 127 255 6.9 0 7.3 6.7 05/23/2005 03:00:00 2.1 0.5 3.4 0.7 2 0.5 3.4 0.4 1.6 0.5 2.6 0.4 131 9 134 255 7.2 0 7.5 7 05/23/2005 03:10:00 1.8 0.4 3 0.7 1.6 0.5 3 0.4 1.1 0.5 2.6 0.4 128 10 112 255 7.3 0 7.5 7.3 05/23/2005 03:20:00 2 0.5 3 0.7 1.8 0.6 3 0.4 1.1 0.5 2.6 0.4 127 13 107 255 7.3 0 7.5 7.3 05/23/2005 03:30:00 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 0.5 0.3 1.9 0.4 122 12 146 255 7.4 0 7.5 7.3 05/23/2005 03:40:00 1.6 0.5 3 0.4 1.3 0.6 2.6 0.4 0.7 0.4 2.3 0.4 110 10 113 255 7.4 0 7.5 7.5 05/23/2005 03:50:00 1.9 0.4 3 0.4 1.6 0.5 3 0.4 1.1 0.6 2.6 0.4 110 10 101 255 7.4 0 7.5 7.3 05/23/2005 04:00:00 2.2 0.3 3 1.1 2.1 0.4 3 1.1 1.2 0.5 2.3 0.4 104 8 93 255 7.6 0 7.8 7.5 05/23/2005 04:10:00 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 0.8 0.5 2.6 0.4 113 15 126 255 7.7 0 7.8 7.5 05/23/2005 04:20:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.7 0.4 1.9 0.4 113 11 112 255 7.8 0 7.8 7.8 05/23/2005 04:30:00 1.9 0.5 3 0.4 1.7 0.5 2.6 0.4 0.8 0.5 2.3 0.4 117 12 97 255 7.8 0 7.8 7.8 05/23/2005 04:40:00 1.7 0.5 2.6 0.4 1.5 0.6 2.6 0.4 0.7 0.5 2.3 0.4 113 11 118 255 7.9 0 8 7.8 05/23/2005 04:50:00 1.9 0.6 3.4 0.4 1.6 0.7 3 0.4 1.1 0.7 3 0.4 117 16 113 255 8 0 8.3 8 05/23/2005 05:00:00 2 0.5 3 0.7 1.8 0.5 3 0.4 1.2 0.5 2.6 0.4 112 10 124 255 8.1 0 8.3 8 05/23/2005 05:10:00 2.1 0.5 3.4 0.7 1.8 0.5 3 0.4 1.1 0.6 2.6 0.4 107 9 114 255 8.3 0 8.5 8.3 05/23/2005 05:20:00 2.3 0.3 3 1.1 2.1 0.3 3 1.1 1.7 0.4 2.6 0.4 107 8 106 255 8.4 0 8.5 8.3 05/23/2005 05:30:00 2.1 0.5 3 0.7 1.9 0.5 3 0.4 1.3 0.6 2.6 0.4 111 11 122 255 8.5 0 8.8 8.5 05/23/2005 05:40:00 1.3 0.6 3 0.4 1 0.6 2.6 0.4 0.5 0.3 1.5 0.4 114 16 112 255 8.9 0 9 8.8 05/23/2005 05:50:00 1.8 0.5 3 0.4 1.5 0.6 3 0.4 1 0.6 2.6 0.4 102 12 93 255 9 0 9 9 05/23/2005 06:00:00 1.7 0.4 2.6 0.4 1.6 0.5 2.6 0.4 1.1 0.6 2.3 0.4 99 9 92 255 9.1 0 9.3 9 05/23/2005 06:10:00 1.3 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.8 0.5 2.3 0.4 90 10 101 255 9.4 0 9.6 9.3 05/23/2005 06:20:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 91 10 95 255 10 0.2 10.6 9.6 05/23/2005 06:30:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.4 1.9 0.4 87 13 105 255 10.4 0 10.6 10.3 05/23/2005 06:40:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 78 12 96 255 10.5 0 10.6 10.3 05/23/2005 06:50:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 83 12 78 255 10.5 0 10.6 10.6 05/23/2005 07:00:00 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 1 0.5 1.9 0.4 78 12 80 255 10.7 0 11.1 10.6 05/23/2005 07:10:00 1.3 0.3 1.9 0.4 1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 78 10 79 255 11.3 0 11.7 10.9 05/23/2005 07:20:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1 0.4 1.9 0.4 35 18 24 255 11.9 0.1 12.2 11.4 05/23/2005 07:30:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1 0.5 2.3 0.4 27 17 18 255 12.5 0.1 13 12.2 05/23/2005 07:40:00 1.2 0.6 2.6 0.4 1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 19 22 18 255 12.7 0 13 12.5 05/23/2005 07:50:00 1.3 0.4 2.3 0.4 1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 10 15 7 255 12.7 0 13 12.5 05/23/2005 08:00:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 29 18 4 255 12.8 0 13.3 12.7 05/23/2005 08:10:00 1 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.9 0.4 1.9 0.4 36 16 14 255 13.1 0.1 13.5 12.7 05/23/2005 08:20:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 27 22 354 255 13.1 0 13.5 12.7 05/23/2005 08:30:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 33 18 52 255 13.3 0 13.8 13 05/23/2005 08:40:00 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 2.3 0.4 20 11 13 255 13.4 0 13.8 13 05/23/2005 08:50:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 21 5 22 255 13.5 0 14.1 13.3 05/23/2005 09:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 28 27 9 255 13.7 0 14.1 13.5 05/23/2005 09:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 11 30 17 255 13.5 0 14.1 13.3 05/23/2005 09:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 336 24 15 255 13.6 0 13.8 13.3 05/23/2005 09:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 325 51 310 255 13.7 0 14.4 13.3 05/23/2005 09:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 244 38 220 255 14.6 0 14.9 14.1 05/23/2005 09:50:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.8 0.5 2.3 0.4 223 28 216 255 15.2 0.2 16 14.6 05/23/2005 10:00:00 0.8 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.8 0.5 2.6 0.4 245 26 266 255 15.7 0 16.3 15.5 05/23/2005 10:10:00 1.6 0.7 3 0.4 1.5 0.7 3 0.4 1.4 0.6 3.4 0.4 268 30 260 255 15.9 0 16.3 15.7 05/23/2005 10:20:00 1.2 0.7 3 0.4 1.1 0.7 3 0.4 1.2 0.6 2.6 0.4 272 30 251 255 16.7 0.3 17.1 16.3 05/23/2005 10:30:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.2 0.6 3 0.4 268 36 255 255 17 0.1 17.4 16.3 05/23/2005 10:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 262 15 266 255 15.3 0.3 16.6 15.2 05/23/2005 10:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 288 2 287 255 15 0 15.7 14.9 05/23/2005 11:00:00 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 255 32 241 255 16.1 0.4 16.6 15.2 05/23/2005 11:10:00 1 0.7 2.6 0.4 1 0.7 2.6 0.4 0.8 0.7 3 0.4 284 41 270 255 16.1 0.2 16.6 15.7 05/23/2005 11:20:00 1.1 0.6 3 0.4 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 270 33 313 255 16.1 0.2 16.6 15.7 05/23/2005 11:30:00 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 269 53 289 255 16.1 0 16.6 16 05/23/2005 11:40:00 1.7 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.7 3 0.4 249 28 259 255 15.6 0 16 15.2 05/23/2005 11:50:00 1.5 0.9 3.8 0.4 1.4 1 3.8 0.4 1.2 0.9 4.2 0.4 255 86 220 255 16.8 0.5 18 16 05/23/2005 12:00:00 2.5 1.4 5.3 0.4 2.4 1.5 5.3 0.4 2.1 1.3 6.1 0.4 282 45 304 255 18.7 0.3 19.4 18 05/23/2005 12:10:00 2.9 1 5.3 0.4 2.8 1.1 5.7 0.4 2.3 1.2 5.3 0.4 304 43 266 255 19.3 0.2 19.7 18.8 05/23/2005 12:20:00 3.3 1.1 6.5 0.7 3.2 1.1 6.5 0.4 2.6 1.3 6.5 0.4 283 36 265 255 19.2 0.3 20 18.8 05/23/2005 12:30:00 2.6 1.3 5.7 0.4 2.5 1.3 5.7 0.4 1.9 1.3 5.3 0.4 299 27 297 255 19 0.1 19.4 18.5 05/23/2005 12:40:00 2.9 1.3 6.1 0.4 2.8 1.3 6.1 0.4 2.5 1.2 5.3 0.4 286 41 294 255 19 0.1 19.4 18.5 05/23/2005 12:50:00 3.6 1.2 6.5 0.7 3.4 1.2 6.1 1.1 2.9 1.3 6.5 0.4 314 22 301 255 18.7 0.2 19.1 18.2 05/23/2005 13:00:00 2.9 1 5.7 0.4 2.8 1.1 5.3 0.4 1.9 1.1 4.9 0.4 301 26 344 255 17.9 0.4 18.2 17.1 05/23/2005 13:10:00 3.2 0.9 5.7 0.7 3 1 5.7 0.4 2.5 1 4.6 0.4 307 17 295 255 17.1 0.2 17.4 16.8 05/23/2005 13:20:00 3 0.8 5.3 0.7 2.8 1 5.3 0.4 2.1 0.9 4.2 0.4 302 16 318 255 16.8 0.1 17.1 16.8 05/23/2005 13:30:00 2.3 0.9 4.9 0.4 2.1 1 4.9 0.4 1.7 0.9 3.8 0.4 285 33 320 255 16.8 0 17.1 16.8 05/23/2005 13:40:00 1.7 0.7 3.4 0.4 1.5 0.7 3 0.4 1.1 0.8 3 0.4 326 30 340 255 17.3 0.5 18.5 16.6 05/23/2005 13:50:00 2.1 0.7 3.8 0.4 1.9 0.8 3.8 0.4 1.5 0.8 3 0.4 321 26 344 255 18.2 0 18.5 17.7 05/23/2005 14:00:00 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 300 23 251 255 17.8 0.1 18.2 17.4 05/23/2005 14:10:00 1.6 0.6 3.4 0.4 1.4 0.7 3 0.4 1.2 0.7 3 0.4 310 23 311 255 17.6 0.1 18.2 17.4 05/23/2005 14:20:00 1.8 0.6 3 0.4 1.6 0.6 2.6 0.4 1.4 0.6 3 0.4 300 12 300 255 17.7 0 18.2 17.4 05/23/2005 14:30:00 1 0.7 3 0.4 0.9 0.7 3 0.4 0.7 0.6 2.3 0.4 312 30 308 255 18 0.1 18.5 17.7 05/23/2005 14:40:00 1.4 0.7 3 0.4 1.2 0.7 3 0.4 1 0.6 2.3 0.4 297 26 258 255 18.6 0.3 19.7 18 05/23/2005 14:50:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.2 1.5 0.4 240 79 348 255 19.4 0.1 20 19.1 05/23/2005 15:00:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 220 32 246 255 19.2 0 19.7 19.1 05/23/2005 15:10:00 1.6 0.9 3.8 0.4 1.4 0.9 3.4 0.4 1.2 0.8 3.4 0.4 317 38 297 255 19.5 0.2 20.3 19.1 05/23/2005 15:20:00 1.3 0.8 3 0.4 1.2 0.8 3.4 0.4 1.1 0.8 3.8 0.4 272 43 247 255 19.2 0.4 20.5 18.8 05/23/2005 15:30:00 3.3 0.9 4.9 0.4 3.2 0.9 4.9 0.4 2.8 1 5.3 0.4 279 32 305 255 19.8 0.4 20.8 19.1 05/23/2005 15:40:00 3.6 1 6.1 1.1 3.5 1 6.1 0.4 2.7 1 4.9 0.4 273 20 233 255 19.4 0.6 20.5 18.5 05/23/2005 15:50:00 3 0.8 4.9 0.4 2.9 0.9 4.9 0.4 2.3 1 4.9 0.4 272 22 263 255 18.7 0 19.1 18.2 05/23/2005 16:00:00 3.4 0.8 4.9 1.5 3.3 0.8 4.9 1.5 2.7 0.8 4.6 0.4 304 18 322 255 18.6 0.2 19.4 18 05/23/2005 16:10:00 1.7 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.1 0.7 3 0.4 287 23 291 255 18.2 0.1 18.5 17.7 05/23/2005 16:20:00 1.3 0.7 2.6 0.4 1.2 0.7 3 0.4 0.6 0.5 3 0.4 260 32 230 255 18.2 0 18.5 17.7 05/23/2005 16:30:00 2.3 0.9 4.9 0.4 2.3 1 4.9 0.4 1.7 1.2 5.7 0.4 186 32 169 255 18.3 0 18.8 18 05/23/2005 16:40:00 2.6 0.9 4.6 0.4 2.7 1 4.6 0.4 2.3 0.9 4.6 0.4 164 15 168 255 17.3 0.2 18.2 16.8 05/23/2005 16:50:00 1.8 1.1 4.9 0.4 1.8 1.1 4.6 0.4 1.2 0.9 4.6 0.4 193 24 195 255 17.1 0 17.4 16.8 05/23/2005 17:00:00 2.1 0.9 4.6 0.4 2 0.9 4.2 0.4 1.3 0.8 3.8 0.4 217 17 220 255 17.2 0 17.4 16.8 05/23/2005 17:10:00 2.4 0.9 4.6 0.7 2.3 1 4.6 0.4 1.3 0.9 4.6 0.4 239 20 238 255 17.1 0 17.1 16.8 05/23/2005 17:20:00 3.2 1.2 6.8 0.7 3.2 1.2 7.2 1.1 2.1 1.2 6.1 0.4 237 22 255 255 16.8 0 16.8 16.8 05/23/2005 17:30:00 4.1 1.2 7.2 1.5 4 1.2 7.6 1.5 2.7 1.3 6.5 0.4 254 26 280 255 16.4 0.2 16.8 16 05/23/2005 17:40:00 3.9 1.7 8.4 0.7 3.8 1.7 8 0.4 2.7 1.7 6.8 0.4 250 28 269 255 15.7 0.2 16.3 15.2 05/23/2005 17:50:00 3.1 1.7 7.2 0.4 3 1.7 8.4 0.4 2 1.4 6.5 0.4 254 49 246 255 15 0 15.5 14.9 05/23/2005 18:00:00 3.8 1.7 8 0.4 3.8 1.7 8.4 0.4 2.9 1.7 6.8 0.4 257 24 219 255 14.6 0 15.2 14.4 05/23/2005 18:10:00 2.9 1.3 6.5 0.4 2.9 1.3 6.8 0.4 2 1.3 6.5 0.4 248 23 264 255 14.3 0 14.6 14.1 05/23/2005 18:20:00 2.9 1.1 5.7 0.4 2.9 1.1 5.7 0.4 2.1 1.1 4.9 0.4 236 24 223 255 14.2 0 14.6 14.1 05/23/2005 18:30:00 3.1 0.9 6.1 0.4 2.9 1.1 5.7 0.4 2.1 0.9 4.6 0.4 239 22 245 255 14.2 0 14.6 13.8 05/23/2005 18:40:00 3 1 5.3 0.7 3 0.9 4.9 0.7 2.1 0.9 4.2 0.4 226 17 208 255 14.2 0 14.6 13.8 05/23/2005 18:50:00 2.4 0.9 4.6 0.4 2.3 0.9 4.6 0.4 1.7 1 4.6 0.4 238 19 234 255 14.2 0 14.6 14.1 05/23/2005 19:00:00 1.5 0.8 4.6 0.4 1.4 0.9 4.2 0.4 1 0.7 3 0.4 227 26 209 255 14.2 0 14.6 14.1 05/23/2005 19:10:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 245 29 241 255 14.2 0.2 14.6 13.8 05/23/2005 19:20:00 0.8 0.5 1.9 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 192 19 233 255 14.2 0.1 14.6 13.8 05/23/2005 19:30:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 193 38 184 255 14 0.1 14.6 13.8 05/23/2005 19:40:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 228 10 245 255 13.9 0 14.4 13.5 05/23/2005 19:50:00 1.2 0.7 3.4 0.4 1.2 0.8 3.4 0.4 0.8 0.7 3 0.4 174 27 184 255 13.8 0 14.4 13.5 05/23/2005 20:00:00 1.3 0.5 3 0.4 1.3 0.6 3 0.4 0.8 0.6 3 0.4 176 17 163 255 13.9 0 14.4 13.8 05/23/2005 20:10:00 1.2 0.6 3 0.4 1 0.6 2.6 0.4 0.7 0.5 3 0.4 159 17 160 255 13.8 0 14.4 13.5 05/23/2005 20:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.9 0.4 169 10 155 255 13.6 0.1 14.1 13.3 05/23/2005 20:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 185 17 189 255 13.3 0.1 13.8 13 05/23/2005 20:40:00 1.2 0.7 3.4 0.4 1.1 0.8 3 0.4 0.6 0.5 2.3 0.4 194 10 195 255 12.9 0.1 13.3 12.5 05/23/2005 20:50:00 2.6 0.6 3.8 1.1 2.7 0.5 3.8 1.1 1.7 0.7 3 0.4 200 13 191 255 12.3 0.1 12.7 11.9 05/23/2005 21:00:00 1.2 1 3.8 0.4 1.1 1 3.8 0.4 0.8 0.6 3 0.4 183 39 188 255 11.9 0.1 12.5 11.7 05/23/2005 21:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 61 87 255 11.7 0.1 12.2 11.4 05/23/2005 21:20:00 0.4 0.3 2.3 0.4 0.4 0.3 2.3 0.4 0.4 0.2 1.9 0.4 87 45 213 255 11.3 0 11.7 11.1 05/23/2005 21:30:00 0.9 0.8 3 0.4 0.9 0.8 3 0.4 0.6 0.5 2.6 0.4 234 30 231 255 11.1 0 11.7 11.1 05/23/2005 21:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 56 337 255 11.1 0 11.4 11.1 05/23/2005 21:50:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 87 6 90 255 10.9 0 11.1 10.9 05/23/2005 22:00:00 1.8 0.5 2.6 0.7 1.6 0.5 2.6 0.4 0.6 0.4 1.9 0.4 82 8 84 255 10.8 0 11.1 10.9 05/23/2005 22:10:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 0.7 0.5 2.3 0.4 78 12 70 255 10.9 0 11.1 10.9 05/23/2005 22:20:00 1.4 0.5 2.3 0.4 1.2 0.6 2.6 0.4 0.4 0.2 1.5 0.4 75 10 68 255 10.9 0 11.1 10.9 05/23/2005 22:30:00 2.5 0.5 3.8 1.5 2.4 0.5 3.4 1.5 1.1 0.6 2.6 0.4 74 10 73 255 10.7 0 10.9 10.6 05/23/2005 22:40:00 2.4 0.6 3.4 1.1 2.3 0.6 3.4 0.7 1.5 0.8 3 0.4 53 13 39 255 10.8 0 11.1 10.6 05/23/2005 22:50:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 0.5 0.4 2.3 0.4 83 20 74 255 10.7 0 10.9 10.6 05/23/2005 23:00:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 91 14 92 255 10.6 0 10.6 10.6 05/23/2005 23:10:00 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 0.4 0.2 1.5 0.4 115 11 102 255 10.5 0 10.6 10.6 05/23/2005 23:20:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 0.7 0.4 127 3 118 255 10.4 0 10.6 10.3 05/23/2005 23:30:00 2 0.5 3 0.7 2 0.6 3 0.7 1.4 0.6 2.6 0.4 139 10 147 255 10.3 0 10.6 10.3 05/23/2005 23:40:00 2.4 0.3 3 1.1 2.3 0.3 3 1.5 1.7 0.5 2.6 0.4 149 9 143 255 10.5 0 10.6 10.3 05/23/2005 23:50:00 2.1 0.4 3 0.7 2.1 0.3 2.6 1.1 1.1 0.5 2.3 0.4 166 8 162 255 10.5 0 10.6 10.3 05/24/2005 00:00:00 2.2 0.4 3 1.1 2.3 0.3 3 1.5 1.5 0.6 2.6 0.4 167 7 163 255 10.4 0 10.6 10.3 05/24/2005 00:10:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.2 0.4 3 1.1 153 4 153 255 10.4 0 10.6 10.3 05/24/2005 00:20:00 3.5 0.4 4.6 1.9 3.5 0.4 4.6 2.6 2.7 0.5 3.8 1.5 160 5 158 255 10.5 0 10.6 10.6 05/24/2005 00:30:00 2.7 0.8 4.6 0.7 2.7 0.9 4.6 0.4 1.7 0.8 3.8 0.4 155 18 159 255 10.5 0 10.6 10.6 05/24/2005 00:40:00 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 67 26 42 255 10.5 0 10.6 10.6 05/24/2005 00:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 87 1 90 255 10.3 0.1 10.6 10.3 05/24/2005 01:00:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0 0.7 0.4 95 14 93 255 10.2 0 10.3 10.1 05/24/2005 01:10:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.4 0.2 1.1 0.4 115 8 115 255 10 0 10.1 10.1 05/24/2005 01:20:00 2.4 0.3 3 1.9 2.3 0.3 3 1.5 0.9 0.4 1.9 0.4 107 6 103 255 10 0 10.1 9.8 05/24/2005 01:30:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.1 1.2 0.5 2.3 0.4 113 10 117 255 10 0 10.3 9.8 05/24/2005 01:40:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.5 1.7 0.5 2.6 0.4 120 7 113 255 10.2 0 10.3 10.1 05/24/2005 01:50:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.5 1.6 0.6 3 0.4 123 10 133 255 10.2 0 10.3 10.1 05/24/2005 02:00:00 3.5 0.4 4.2 2.3 3.5 0.4 4.2 2.3 2.6 0.5 3.8 1.1 131 8 153 255 10.1 0 10.3 10.1 05/24/2005 02:10:00 1.9 1.1 4.2 0.4 1.7 1.2 4.2 0.4 1.5 0.9 3.4 0.4 62 86 127 255 10 0 10.1 9.8 05/24/2005 02:20:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 309 11 309 255 9.7 0 9.8 9.6 05/24/2005 02:30:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.2 1.1 0.4 269 11 282 255 9.5 0 9.6 9.3 05/24/2005 02:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 256 4 247 255 9.5 0 9.6 9.3 05/24/2005 02:50:00 1.9 0.4 2.6 1.1 1.7 0.6 2.6 0.4 1 0.4 1.9 0.4 229 7 229 255 9.2 0 9.6 9 05/24/2005 03:00:00 1.8 0.4 2.6 1.1 1.7 0.4 2.3 0.7 0.6 0.3 1.9 0.4 203 6 218 255 9 0 9.3 8.8 05/24/2005 03:10:00 1.6 0.3 2.3 0.7 1.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 207 4 202 255 8.7 0.1 9 8.5 05/24/2005 03:20:00 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0.1 0.7 0.4 237 58 184 255 8.4 0 8.5 8.5 05/24/2005 03:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 348 22 11 255 8.4 0 8.5 8.5 05/24/2005 03:40:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 58 38 67 255 8.6 0 8.8 8.5 05/24/2005 03:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 168 38 104 255 8.7 0 9 8.5 05/24/2005 04:00:00 1.4 0.8 3.4 0.4 1.2 0.9 3 0.4 0.6 0.4 1.9 0.4 241 11 226 255 8.9 0 9 8.8 05/24/2005 04:10:00 1.8 0.8 3.4 0.4 1.6 0.9 3 0.4 0.7 0.5 2.3 0.4 232 9 223 255 9 0 9 9 05/24/2005 04:20:00 0.7 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 241 9 256 255 9.1 0 9.3 9 05/24/2005 04:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 257 0 257 255 9.2 0 9.3 9 05/24/2005 04:40:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 293 22 307 255 9.4 0 9.6 9.3 05/24/2005 04:50:00 1.3 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.1 1.1 0.4 277 17 278 255 9.5 0 9.6 9.3 05/24/2005 05:00:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 283 11 287 255 9.6 0 9.8 9.6 05/24/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 7 255 255 9.8 0 9.8 9.6 05/24/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 304 0 255 255 9.8 0 9.8 9.8 05/24/2005 05:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 28 318 255 10 0 10.1 9.8 05/24/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 255 255 10.1 0 10.3 10.1 05/24/2005 05:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 3 255 10.5 0.3 11.1 10.3 05/24/2005 06:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 11 3 255 11.2 0 11.4 11.1 05/24/2005 06:10:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 338 6 341 255 11.3 0 11.4 11.1 05/24/2005 06:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 311 15 328 255 11.5 0 11.7 11.4 05/24/2005 06:30:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 275 15 303 255 11.7 0 11.9 11.4 05/24/2005 06:40:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.9 0.4 297 8 302 255 11.7 0 11.7 11.7 05/24/2005 06:50:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 320 8 302 255 11.8 0 11.9 11.7 05/24/2005 07:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 302 9 302 255 12.1 0 12.5 11.7 05/24/2005 07:10:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 312 0 312 255 12.3 0 12.7 12.2 05/24/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 314 8 344 255 12.1 0.1 12.5 11.9 05/24/2005 07:30:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 346 13 358 255 12.8 0.4 13.8 12.2 05/24/2005 07:40:00 1.1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.5 2.3 0.4 358 21 3 255 13.4 0.2 13.8 13 05/24/2005 07:50:00 0.7 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.4 1.9 0.4 21 12 26 255 13.9 0.2 14.6 13.5 05/24/2005 08:00:00 1.1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 14 17 353 255 14.7 0.3 15.5 14.4 05/24/2005 08:10:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 9 36 273 255 15.2 0.1 16 15.2 05/24/2005 08:20:00 1.6 0.5 3 0.4 1.4 0.6 3 0.4 1.4 0.6 2.6 0.4 287 22 299 255 15 0 15.5 14.6 05/24/2005 08:30:00 1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.5 2.3 0.4 299 9 301 255 13.7 0.4 14.9 13 05/24/2005 08:40:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 294 7 284 255 12.9 0.1 13.3 12.7 05/24/2005 08:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 302 7 295 255 12.9 0 13 12.7 05/24/2005 09:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 304 17 298 255 13.2 0 13.3 12.7 05/24/2005 09:10:00 0.9 0.7 2.6 0.4 0.8 0.7 3 0.4 0.8 0.6 2.3 0.4 271 47 211 255 13.5 0 14.4 13.3 05/24/2005 09:20:00 2.2 0.4 3 0.7 2.1 0.4 3 0.4 1.6 0.5 3 0.4 229 12 226 255 14.1 0.1 14.6 13.5 05/24/2005 09:30:00 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 231 20 270 255 13.9 0 14.6 13.5 05/24/2005 09:40:00 1.2 0.6 3 0.4 1 0.7 3 0.4 0.7 0.6 3.4 0.4 246 39 294 255 13.5 0.1 13.8 13 05/24/2005 09:50:00 1.3 0.8 3 0.4 1.2 0.8 3 0.4 1 0.7 3.4 0.4 297 27 281 255 13.4 0 13.8 13 05/24/2005 10:00:00 2.3 1 4.9 0.4 2.2 1 4.9 0.4 1.7 1 4.2 0.4 254 26 288 255 13.5 0 13.8 13.3 05/24/2005 10:10:00 2.3 1 4.9 0.4 2.1 1.2 4.6 0.4 1.3 0.9 4.2 0.4 264 27 295 255 13.8 0.1 14.6 13.5 05/24/2005 10:20:00 2.7 1.1 5.3 0.4 2.7 1.1 5.3 0.4 1.7 1.1 4.6 0.4 255 26 244 255 13.9 0 14.4 13.8 05/24/2005 10:30:00 3.3 1 5.7 0.7 3.3 1 6.1 0.4 2.6 0.9 4.9 0.4 249 21 263 255 14.7 0.4 15.7 13.8 05/24/2005 10:40:00 2.7 0.7 4.9 1.1 2.7 0.8 4.6 0.4 2.1 0.8 4.2 0.4 238 29 212 255 15.5 0.2 16 14.9 05/24/2005 10:50:00 3 1.1 6.1 0.4 2.9 1.2 6.1 0.4 2.3 1.1 5.3 0.4 269 22 274 255 15.7 0.2 16.3 15.2 05/24/2005 11:00:00 3 1 4.9 0.7 2.8 1 4.9 0.4 2.3 1 4.6 0.4 285 23 224 255 15.2 0.1 15.7 14.9 05/24/2005 11:10:00 2.8 1.2 5.3 0.4 2.8 1.3 5.3 0.4 2.4 1.2 4.9 0.4 273 45 280 255 16.1 0.5 16.8 15.2 05/24/2005 11:20:00 2.3 1 5.3 0.4 2 1.2 5.3 0.4 1.9 1 4.2 0.4 289 28 311 255 16.2 0.1 16.8 16 05/24/2005 11:30:00 2.2 0.9 4.9 0.4 2.1 1 4.9 0.4 1.5 0.9 3.8 0.4 243 43 225 255 16.3 0 16.8 16 05/24/2005 11:40:00 2.9 1.1 4.9 0.4 2.8 1.2 5.3 0.4 2.1 1.1 4.6 0.4 250 39 263 255 15.8 0.3 16.3 15.5 05/24/2005 11:50:00 2.9 1 4.6 0.7 2.8 1 4.6 0.4 2.3 1 4.6 0.4 249 28 253 255 15.6 0 15.7 15.5 05/24/2005 12:00:00 3 1 6.1 1.1 3 1 5.7 0.7 2.4 1.1 5.3 0.4 272 22 257 255 15.5 0 16 15.5 05/24/2005 12:10:00 3.5 0.9 6.5 1.9 3.4 1 5.7 1.1 2.7 1 5.3 0.4 278 21 294 255 15.8 0 16.3 15.7 05/24/2005 12:20:00 2.9 0.9 4.9 0.7 2.9 1 4.9 0.4 2.2 1 4.6 0.4 265 27 280 255 15.8 0.2 16.3 15.7 05/24/2005 12:30:00 3.8 1.1 6.1 1.5 3.7 1.2 6.5 0.4 3 1.3 6.1 0.7 291 24 287 255 15.9 0.2 16.6 15.5 05/24/2005 12:40:00 2.3 0.9 4.9 0.4 2 1 4.6 0.4 1.7 0.9 3.8 0.4 291 29 267 255 16.3 0.3 16.8 15.7 05/24/2005 12:50:00 2.4 1.1 4.9 0.4 2.3 1.2 4.9 0.4 2.1 1.1 4.6 0.4 280 32 287 255 16.1 0 16.6 16 05/24/2005 13:00:00 2.6 0.8 4.9 0.4 2.5 0.9 4.6 0.4 1.9 0.9 4.6 0.4 278 32 328 255 17.1 0.1 17.4 16.6 05/24/2005 13:10:00 3.4 1.2 6.1 0.7 3.4 1.2 6.1 0.4 2.8 1.1 6.1 0.7 265 26 261 255 16.7 0 16.8 16.6 05/24/2005 13:20:00 2.1 1 4.6 0.4 1.9 1.1 4.6 0.4 1.7 0.9 4.6 0.4 274 36 287 255 16.8 0 16.8 16.6 05/24/2005 13:30:00 2.6 1 4.6 0.4 2.5 1 4.9 0.4 1.9 1.1 4.2 0.4 220 35 221 255 16.7 0 16.8 16.6 05/24/2005 13:40:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 1.9 1 4.2 0.4 247 27 230 255 16.7 0.2 17.1 16.6 05/24/2005 13:50:00 3 1.2 5.7 0.4 2.9 1.2 6.1 0.4 2.2 1.1 4.6 0.4 252 28 289 255 16.4 0 16.8 16.3 05/24/2005 14:00:00 3.5 1 6.1 1.1 3.4 1 6.1 0.7 2.6 1 5.7 0.7 217 21 194 255 16.7 0 16.8 16.6 05/24/2005 14:10:00 2.9 1.2 6.1 0.4 2.9 1.2 6.1 0.4 2.3 1.3 6.5 0.4 234 30 223 255 17 0.3 17.4 16.6 05/24/2005 14:20:00 3.1 1.1 6.1 0.7 3.1 1 6.5 0.4 2.3 1.1 5.3 0.4 244 32 207 255 17.1 0 17.1 16.8 05/24/2005 14:30:00 2.5 1 4.6 0.4 2.5 1.1 4.6 0.4 2 0.9 4.6 0.4 241 41 241 255 16.9 0 17.1 16.8 05/24/2005 14:40:00 2.3 1 4.6 0.4 2.1 1.1 5.3 0.4 1.8 1 4.2 0.4 234 47 222 255 17.3 0 17.4 17.1 05/24/2005 14:50:00 4.2 1.5 7.2 0.4 4.2 1.5 7.2 0.4 3.5 1.5 7.6 0.7 261 23 264 255 17.3 0 17.7 16.8 05/24/2005 15:00:00 3.3 1 6.5 0.7 3.1 1.2 6.1 0.4 2.5 1.1 6.1 0.4 274 23 268 255 17.3 0.7 19.1 16.6 05/24/2005 15:10:00 4.8 1.2 7.6 2.3 4.7 1.3 7.6 2.3 3.9 1.4 7.6 1.1 289 22 276 255 17.7 0.7 19.4 16.8 05/24/2005 15:20:00 3.9 1.1 6.5 1.9 3.8 1.2 6.1 0.7 3.2 1.2 6.1 0.4 273 19 246 255 16.4 0.3 17.1 16 05/24/2005 15:30:00 2.9 1.2 6.5 0.4 2.8 1.2 6.1 0.4 2.3 1.1 5.3 0.4 255 24 270 255 15.5 0 16 15.5 05/24/2005 15:40:00 2.4 1 4.9 0.4 2.3 1.1 4.9 0.4 1.8 1 4.2 0.4 260 30 253 255 15.6 0 15.7 15.5 05/24/2005 15:50:00 2.4 1.1 4.9 0.4 2.3 1.1 4.9 0.4 1.8 1.1 4.9 0.4 229 23 222 255 16.1 0.2 16.8 15.7 05/24/2005 16:00:00 3.2 1 5.3 0.4 3.2 1 5.3 0.4 2.3 1 4.6 0.4 228 22 243 255 16.6 0 16.8 16.3 05/24/2005 16:10:00 2.1 1 4.6 0.4 2 1.1 4.6 0.4 1.6 1 4.6 0.4 228 26 252 255 15.8 0.2 16.3 15.5 05/24/2005 16:20:00 2 0.9 4.2 0.4 1.8 1 4.2 0.4 1.2 0.8 3.4 0.4 225 24 244 255 15.1 0.1 15.7 14.9 05/24/2005 16:30:00 2.4 0.5 3.8 1.1 2.3 0.6 3.8 1.1 1.7 0.7 3 0.4 220 16 237 255 14.8 0 15.2 14.6 05/24/2005 16:40:00 2.2 0.6 3.8 0.4 2.1 0.7 3.8 0.4 1.5 0.7 3.4 0.4 201 22 189 255 14.9 0 15.5 14.6 05/24/2005 16:50:00 2.6 0.7 4.2 0.4 2.6 0.7 4.2 0.4 1.9 0.9 3.8 0.4 203 20 197 255 15.2 0.1 15.7 14.9 05/24/2005 17:00:00 2.2 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.7 0.8 3.4 0.4 199 16 189 255 15.2 0.1 15.7 15.2 05/24/2005 17:10:00 1.7 0.6 3 0.4 1.7 0.7 3 0.4 1.5 0.7 3.4 0.4 188 16 215 255 14.9 0.2 15.7 14.6 05/24/2005 17:20:00 1.1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.7 0.5 3 0.4 213 38 236 255 14.8 0 15.5 14.6 05/24/2005 17:30:00 1.7 0.5 3 0.4 1.6 0.5 2.6 0.4 1.2 0.6 2.6 0.4 214 22 230 255 14.9 0 15.5 14.6 05/24/2005 17:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 248 13 234 255 14.4 0 15.2 14.4 05/24/2005 17:50:00 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 244 14 262 255 14.4 0 14.6 14.4 05/24/2005 18:00:00 1.5 0.5 2.3 0.4 1.3 0.6 2.3 0.4 0.9 0.6 2.6 0.4 256 20 255 255 14.2 0 14.9 14.1 05/24/2005 18:10:00 1.5 1 4.6 0.4 1.5 1 4.6 0.4 0.9 0.7 3.4 0.4 263 36 267 255 14.2 0 14.6 14.1 05/24/2005 18:20:00 1.6 0.8 3.4 0.4 1.4 1 3.4 0.4 1.2 0.9 3.4 0.4 291 32 302 255 14.2 0.2 14.9 13.8 05/24/2005 18:30:00 1.7 0.7 3.8 0.4 1.5 0.8 3.8 0.4 1.1 0.6 3 0.4 279 28 245 255 14.2 0.2 14.6 13.8 05/24/2005 18:40:00 2.5 0.8 4.2 0.7 2.4 0.9 4.2 0.4 1.8 0.9 4.2 0.4 268 15 278 255 13.9 0.1 14.6 13.8 05/24/2005 18:50:00 1.9 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.6 3 0.4 259 17 284 255 13.7 0.1 14.4 13.5 05/24/2005 19:00:00 1.4 0.5 2.3 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 272 18 267 255 13.5 0 13.8 13.3 05/24/2005 19:10:00 1.6 0.6 3 0.4 1.5 0.7 3 0.4 1.1 0.6 2.6 0.4 272 17 278 255 13.4 0 13.8 13.3 05/24/2005 19:20:00 1.5 0.7 3 0.4 1.2 0.7 3 0.4 0.8 0.6 2.6 0.4 258 20 270 255 13.3 0 13.8 13 05/24/2005 19:30:00 0.9 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.6 0.5 2.3 0.4 233 33 267 255 13.1 0 13.5 13 05/24/2005 19:40:00 1.4 0.8 3.8 0.4 1.2 0.8 3.8 0.4 0.9 0.6 3.4 0.4 246 16 243 255 13.1 0.1 13.5 12.7 05/24/2005 19:50:00 1 0.6 3 0.4 0.9 0.6 3 0.4 0.7 0.5 2.6 0.4 248 30 255 255 12.9 0.1 13.3 12.7 05/24/2005 20:00:00 1.2 0.7 3 0.4 1 0.7 3 0.4 0.6 0.4 2.3 0.4 221 17 232 255 12.9 0 13.3 12.7 05/24/2005 20:10:00 1.6 0.6 3 0.4 1.5 0.6 2.6 0.4 0.8 0.5 2.3 0.4 208 15 217 255 12.6 0 13 12.5 05/24/2005 20:20:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.4 0.9 0.4 2.3 0.4 227 12 211 255 12.4 0 12.5 12.2 05/24/2005 20:30:00 2 0.4 3 0.7 1.9 0.5 3 0.4 1.1 0.5 2.3 0.4 210 13 223 255 11.9 0.2 12.2 11.7 05/24/2005 20:40:00 1.2 0.7 3 0.4 1 0.7 2.6 0.4 0.5 0.3 1.9 0.4 203 9 202 255 11.7 0 12.2 11.4 05/24/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 199 0 255 255 11.3 0 11.7 11.1 05/24/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 199 0 255 255 10.9 0.1 11.1 10.6 05/24/2005 21:10:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 207 8 199 255 10.6 0 10.9 10.6 05/24/2005 21:20:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 215 0 216 255 10.2 0 10.6 10.1 05/24/2005 21:30:00 1 0.4 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 219 13 225 255 9.8 0.1 10.1 9.6 05/24/2005 21:40:00 0.9 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 236 9 230 255 9.6 0 9.8 9.6 05/24/2005 21:50:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 245 0 245 255 9.5 0 9.6 9.3 05/24/2005 22:00:00 1.3 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.5 0.3 1.9 0.4 219 11 228 255 9.3 0 9.6 9 05/24/2005 22:10:00 1.7 0.3 2.6 0.7 1.6 0.4 2.6 0.4 0.6 0.3 1.5 0.4 237 11 221 255 9 0 9.3 8.8 05/24/2005 22:20:00 1.9 0.5 3 0.4 1.8 0.5 2.6 0.7 0.7 0.5 2.3 0.4 268 12 284 255 8.7 0.1 9 8.5 05/24/2005 22:30:00 1.9 0.5 3 1.1 1.8 0.5 3 0.4 0.7 0.4 1.9 0.4 277 10 275 255 8.3 0 8.5 8.3 05/24/2005 22:40:00 1.1 0.5 2.3 0.4 0.8 0.6 2.3 0.4 0.4 0.2 1.5 0.4 279 7 277 255 8.2 0 8.5 8.3 05/24/2005 22:50:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0 0.4 0.4 286 9 297 255 8.2 0 8.3 8.3 05/24/2005 23:00:00 2 0.3 2.6 1.1 1.8 0.3 2.3 0.7 0.6 0.3 1.5 0.4 295 4 295 255 8.2 0 8.3 8.3 05/24/2005 23:10:00 1.7 0.3 2.3 1.1 1.5 0.4 2.3 0.4 0.5 0.2 1.5 0.4 296 2 294 255 8.3 0 8.3 8.3 05/24/2005 23:20:00 1.6 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.4 0.2 1.1 0.4 297 4 296 255 8.1 0 8.3 8 05/24/2005 23:30:00 1.7 0.3 2.3 0.7 1.4 0.5 2.3 0.4 0.4 0.2 1.1 0.4 294 5 297 255 8 0 8.3 8 05/24/2005 23:40:00 0.6 0.3 1.9 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 8 0 8.3 7.8 05/24/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 255 255 7.9 0 8 7.8 05/25/2005 00:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 255 8 0 8.3 7.8 05/25/2005 00:10:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 250 13 253 255 8.2 0 8.3 8.3 05/25/2005 00:20:00 1.2 0.2 1.9 0.7 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 232 11 247 255 8.2 0 8.3 8.3 05/25/2005 00:30:00 1.3 0.2 1.9 0.7 1 0.4 1.9 0.4 0.4 0.1 0.7 0.4 225 6 219 255 8.1 0 8.3 8.3 05/25/2005 00:40:00 1.4 0.4 2.3 0.7 1.3 0.4 1.9 0.4 0.4 0.2 1.5 0.4 236 4 240 255 8.1 0 8.3 8 05/25/2005 00:50:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 239 9 246 255 7.9 0 8 7.8 05/25/2005 01:00:00 1.5 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.4 0.2 1.1 0.4 246 6 250 255 7.8 0 7.8 7.8 05/25/2005 01:10:00 1.2 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0.1 0.7 0.4 241 3 241 255 7.6 0 7.8 7.5 05/25/2005 01:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 251 1 247 255 7.3 0 7.5 7.3 05/25/2005 01:30:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 112 6 255 7 0.1 7.3 6.7 05/25/2005 01:40:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 8 6 255 6.7 0 7 6.7 05/25/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 255 255 6.6 0 6.7 6.5 05/25/2005 02:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 83 86 207 255 6.6 0 6.7 6.5 05/25/2005 02:10:00 0.9 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 207 0 207 255 6.6 0 6.7 6.5 05/25/2005 02:20:00 0.8 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 206 2 207 255 6.3 0.1 6.5 6.2 05/25/2005 02:30:00 0.9 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 207 1 204 255 6.2 0 6.2 6 05/25/2005 02:40:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 207 255 5.9 0 6.2 5.7 05/25/2005 02:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 10 206 255 5.9 0 6 5.7 05/25/2005 03:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 0 185 255 5.7 0 5.7 5.5 05/25/2005 03:10:00 0.9 0.3 1.5 0.4 0.8 0.5 1.5 0.4 0.4 0 0.4 0.4 180 5 185 255 5.6 0 5.7 5.5 05/25/2005 03:20:00 0.8 0.2 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 173 2 173 255 5.6 0 5.7 5.5 05/25/2005 03:30:00 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.7 0.4 0 0.4 0.4 192 8 206 255 5.6 0 6 5.5 05/25/2005 03:40:00 1.7 0.3 2.3 1.1 1.5 0.3 2.3 0.7 0.5 0.2 1.5 0.4 215 4 206 255 5.6 0 5.7 5.5 05/25/2005 03:50:00 1.5 0.2 1.9 0.7 1.3 0.2 1.9 0.7 0.4 0.1 0.7 0.4 209 3 214 255 5.6 0 5.7 5.5 05/25/2005 04:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 207 0 207 255 5.6 0 5.7 5.5 05/25/2005 04:10:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 207 0 206 255 5.6 0 5.7 5.5 05/25/2005 04:20:00 1.6 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.5 0.3 1.5 0.4 156 15 152 255 5.6 0 6 5.5 05/25/2005 04:30:00 1.7 0.2 2.3 1.1 1.5 0.2 1.9 0.7 0.5 0.2 1.1 0.4 147 2 148 255 5.6 0 6 5.5 05/25/2005 04:40:00 2 0.4 2.6 1.1 1.8 0.4 2.6 0.7 0.9 0.5 2.3 0.4 144 6 138 255 5.6 0 6 5.2 05/25/2005 04:50:00 2.1 0.2 2.6 1.5 1.9 0.3 2.6 1.5 0.8 0.5 2.3 0.4 154 5 157 255 5.4 0 5.7 5.2 05/25/2005 05:00:00 1.5 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.4 0.1 1.1 0.4 139 3 142 255 5.4 0 5.7 5.2 05/25/2005 05:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 0 134 255 5.4 0 5.7 5.2 05/25/2005 05:20:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 5.6 0 5.7 5.5 05/25/2005 05:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 5.9 0 6.2 5.7 05/25/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 255 255 6.2 0 6.2 6 05/25/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 6.4 0 6.7 6.2 05/25/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 255 255 6.9 0.1 7.3 6.7 05/25/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 255 255 7.4 0 7.8 7.3 05/25/2005 06:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 8 0.1 8.5 7.5 05/25/2005 06:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 8.5 0.1 9 8.3 05/25/2005 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 9 0 9.3 8.8 05/25/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 255 255 9.5 0.1 9.8 9.3 05/25/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 255 255 9.9 0 10.1 9.6 05/25/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 255 255 10.2 0 10.6 10.1 05/25/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 39 214 255 10.6 0.1 11.1 10.3 05/25/2005 07:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 218 255 11.1 0.1 11.4 10.9 05/25/2005 07:40:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 242 18 233 255 11.7 0 11.9 11.4 05/25/2005 07:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 210 1 211 255 11.9 0 12.2 11.7 05/25/2005 08:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 237 20 211 255 12.1 0 12.5 11.9 05/25/2005 08:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 242 27 268 255 12.3 0 12.7 11.9 05/25/2005 08:20:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 317 30 306 255 12.1 0 12.5 11.9 05/25/2005 08:30:00 1.2 0.4 2.6 0.4 0.8 0.5 2.3 0.4 0.9 0.4 2.3 0.4 20 17 17 255 12.3 0 12.7 11.9 05/25/2005 08:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 27 7 11 255 12.5 0.1 13 12.2 05/25/2005 08:50:00 0.7 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 29 28 27 255 12.7 0.3 13.3 12.2 05/25/2005 09:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 71 21 73 255 13.3 0.2 13.8 12.7 05/25/2005 09:10:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 77 24 53 255 13.4 0 13.8 13 05/25/2005 09:20:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 69 69 32 255 13.5 0.2 14.6 13.3 05/25/2005 09:30:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 6 49 17 255 14.8 0.3 15.5 14.4 05/25/2005 09:40:00 0.9 0.6 3 0.4 0.8 0.6 3 0.4 1 0.7 3 0.4 69 82 141 255 15.3 0.1 15.7 14.9 05/25/2005 09:50:00 1.9 0.7 3.8 0.4 1.9 0.8 3.8 0.4 1.7 0.8 3.4 0.4 167 28 163 255 14.6 0 15.2 14.4 05/25/2005 10:00:00 1.8 0.6 3 0.4 1.7 0.7 3 0.4 1.4 0.7 3 0.4 193 19 194 255 14.8 0.3 15.7 14.6 05/25/2005 10:10:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.3 0.6 3.8 0.4 206 15 200 255 14.6 0.2 15.5 14.1 05/25/2005 10:20:00 1.4 0.4 2.3 0.4 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 171 24 164 255 14.2 0.5 15.5 13.5 05/25/2005 10:30:00 0.8 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 2.3 0.4 182 28 215 255 14.3 0.3 15.2 13.5 05/25/2005 10:40:00 1.4 0.7 3.8 0.4 1.2 0.7 3.8 0.4 1.2 0.6 3 0.4 147 35 192 255 15.3 0.2 16 14.9 05/25/2005 10:50:00 1.4 0.6 3.4 0.4 1.3 0.7 3.4 0.4 1.3 0.6 3.4 0.4 171 32 211 255 15.9 0.3 16.6 15.5 05/25/2005 11:00:00 1.5 0.7 3 0.4 1.5 0.8 3 0.4 1.4 0.7 3.4 0.4 246 51 296 255 16.6 0.2 17.1 16.3 05/25/2005 11:10:00 2.2 1 4.2 0.4 2 1 4.2 0.4 1.8 0.9 4.2 0.4 281 30 295 255 16.7 0.3 17.1 16.3 05/25/2005 11:20:00 1.4 0.8 3.4 0.4 1.1 0.8 3.8 0.4 1 0.8 3 0.4 281 69 290 255 16.4 0.2 17.1 16.3 05/25/2005 11:30:00 2.3 0.7 4.2 0.4 2 0.7 4.2 0.4 1.5 0.8 3.8 0.4 339 20 353 255 17 0 17.4 16.8 05/25/2005 11:40:00 2.5 0.5 3.8 1.5 2.3 0.5 3.8 1.1 2.1 0.8 3.8 0.4 331 17 349 255 16.9 0.2 17.4 16.6 05/25/2005 11:50:00 1.3 0.6 3 0.4 1.1 0.6 2.6 0.4 1.1 0.6 3 0.4 46 86 319 255 16.8 0 17.4 16.6 05/25/2005 12:00:00 1.3 1 4.6 0.4 1.2 1 4.2 0.4 1.1 0.9 3.8 0.4 234 45 297 255 17.1 0.1 17.7 16.8 05/25/2005 12:10:00 1.9 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 21 98 355 255 17.3 0.2 18 16.8 05/25/2005 12:20:00 1.5 0.7 3.4 0.4 1.3 0.7 3 0.4 1.3 0.6 3 0.4 68 45 37 255 18 0.2 18.5 17.4 05/25/2005 12:30:00 1.8 0.8 3.8 0.4 1.6 0.9 3.8 0.4 1.5 0.8 3.8 0.4 2 35 331 255 18.1 0.4 19.1 17.1 05/25/2005 12:40:00 2.2 0.8 4.6 0.4 2 0.9 4.2 0.4 1.6 0.9 4.6 0.4 359 18 18 255 17.8 0.2 18.5 17.4 05/25/2005 12:50:00 1 0.7 3 0.4 0.8 0.7 3 0.4 0.7 0.6 3 0.4 49 86 331 255 17.7 0.3 18.5 17.1 05/25/2005 13:00:00 0.8 0.5 2.6 0.4 0.6 0.4 2.6 0.4 0.7 0.4 2.3 0.4 134 82 141 255 18.4 0.3 19.1 17.7 05/25/2005 13:10:00 1.4 0.7 3 0.4 1.2 0.7 2.6 0.4 1.3 0.8 3 0.4 8 72 266 255 18 0.5 19.1 17.1 05/25/2005 13:20:00 1.7 0.6 3 0.4 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 316 41 334 255 17.5 0.3 18.2 17.1 05/25/2005 13:30:00 1.5 0.7 3 0.4 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 234 45 235 255 17.3 0.2 18.2 16.8 05/25/2005 13:40:00 1.8 0.9 4.2 0.4 1.6 1 4.6 0.4 1.3 0.8 4.2 0.4 272 32 238 255 18.2 0.1 18.5 17.7 05/25/2005 13:50:00 2.3 1.1 5.3 0.4 2.1 1.1 5.3 0.4 2 1.1 4.2 0.4 313 47 300 255 18 0.2 18.8 17.7 05/25/2005 14:00:00 2.4 1 4.9 0.4 2.1 1.2 4.9 0.4 1.8 1.1 4.9 0.4 301 39 274 255 17.9 0.1 18.5 17.4 05/25/2005 14:10:00 2.9 1 5.3 0.4 2.8 1.1 4.9 0.4 2.6 1 5.3 0.4 272 27 267 255 17.6 0.1 18.2 17.4 05/25/2005 14:20:00 3.1 1 4.9 0.4 2.9 1 5.7 0.4 2.4 1 5.3 0.4 311 24 305 255 18 0.1 18.2 17.7 05/25/2005 14:30:00 2 0.7 3.4 0.4 1.8 0.8 3.4 0.4 1.7 0.7 3.4 0.4 300 26 317 255 18.2 0.1 18.8 18 05/25/2005 14:40:00 2.4 0.8 4.6 0.7 2.2 0.9 4.6 0.4 2 1 4.9 0.4 313 33 313 255 18.5 0.1 19.1 18.2 05/25/2005 14:50:00 2.8 0.6 4.2 1.5 2.6 0.7 4.6 0.7 2.2 0.8 4.2 0.4 295 27 297 255 18.3 0.3 19.1 17.7 05/25/2005 15:00:00 2.3 0.9 4.2 0.4 2.1 1 4.9 0.4 1.9 0.9 4.2 0.4 288 32 290 255 18.3 0.3 19.1 17.7 05/25/2005 15:10:00 2 0.9 4.2 0.4 1.8 1 4.6 0.4 1.5 0.7 4.2 0.4 36 102 226 255 18.8 0.4 19.7 18.2 05/25/2005 15:20:00 2.2 0.7 4.9 0.7 2 0.8 4.6 0.4 1.7 0.6 3.8 0.4 10 17 16 255 20 0.1 20.5 19.7 05/25/2005 15:30:00 1.9 0.8 4.2 0.4 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 319 56 313 255 19.8 0 20.3 19.4 05/25/2005 15:40:00 2.3 1.1 4.6 0.4 2 1 4.2 0.4 1.6 1 3.8 0.4 308 53 308 255 19.7 0.2 20 19.4 05/25/2005 15:50:00 2.7 1 4.9 0.7 2.5 1 4.9 0.4 2.1 1 4.9 0.4 305 30 322 255 19.6 0 20 19.4 05/25/2005 16:00:00 2 1.2 4.9 0.4 1.9 1.2 4.9 0.4 1.6 1 3.8 0.4 333 49 24 255 19.9 0.1 20.3 19.4 05/25/2005 16:10:00 1.9 0.9 3.8 0.4 1.8 0.9 3.4 0.4 1.4 0.9 3.4 0.4 319 61 11 255 20.3 0 20.5 20.3 05/25/2005 16:20:00 2.1 1 4.2 0.4 2 1 4.2 0.4 1.8 0.9 3.8 0.4 292 47 300 255 19.7 0.3 20.5 19.4 05/25/2005 16:30:00 1.9 1.1 4.6 0.4 1.7 1.2 4.6 0.4 1.3 1 4.2 0.4 288 29 284 255 18.5 0.4 19.7 18 05/25/2005 16:40:00 1 0.8 2.6 0.4 0.9 0.7 2.6 0.4 0.7 0.6 2.6 0.4 287 58 339 255 17.7 0 18.2 17.4 05/25/2005 16:50:00 1.5 0.9 3.4 0.4 1.4 0.9 3.4 0.4 1.4 0.9 3.4 0.4 297 27 335 255 17.6 0 18 17.4 05/25/2005 17:00:00 2.4 1 4.6 0.4 2.3 1 4.6 0.4 1.9 0.9 4.2 0.4 262 36 256 255 18.3 0.1 18.5 18 05/25/2005 17:10:00 1.6 1 4.2 0.4 1.5 1 3.8 0.4 1.2 0.8 3.4 0.4 262 64 265 255 18.5 0.1 18.8 18.2 05/25/2005 17:20:00 1.4 0.7 3.8 0.4 1.3 0.8 3.4 0.4 1.3 0.8 3.4 0.4 251 79 305 255 18.5 0.1 18.8 18.2 05/25/2005 17:30:00 1.5 0.7 3.8 0.4 1.2 0.8 4.2 0.4 1.1 0.8 3.8 0.4 309 47 262 255 18.5 0.1 19.1 18.2 05/25/2005 17:40:00 2.1 0.9 4.2 0.4 2 0.9 4.2 0.4 1.4 0.9 4.2 0.4 291 33 335 255 18.5 0.2 19.1 18 05/25/2005 17:50:00 2.1 0.6 3.8 0.4 2.1 0.6 3.4 0.4 1.6 0.7 3.8 0.4 268 22 277 255 18 0.2 18.5 17.4 05/25/2005 18:00:00 3.1 1.1 4.9 0.4 3 1.1 4.9 0.4 2.5 1 4.6 0.4 303 22 295 255 17.9 0.2 18.5 17.4 05/25/2005 18:10:00 2.9 0.9 5.3 1.1 2.9 0.9 5.7 1.1 2.4 0.9 4.9 0.7 270 21 269 255 17.8 0.1 18.5 17.4 05/25/2005 18:20:00 2.1 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.5 0.9 3.8 0.4 302 30 290 255 17.3 0 18 17.1 05/25/2005 18:30:00 2.5 0.9 4.6 0.4 2.4 1 4.6 0.4 1.8 1 4.6 0.4 298 18 298 255 17 0.1 17.1 16.8 05/25/2005 18:40:00 2.1 0.6 3.8 0.4 1.8 0.7 3.8 0.4 1.5 0.7 3 0.4 306 16 313 255 16.7 0 16.8 16.8 05/25/2005 18:50:00 1.2 0.6 2.6 0.4 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 304 18 294 255 16.6 0 16.8 16.6 05/25/2005 19:00:00 2.3 1.5 6.1 0.4 2.2 1.5 5.7 0.4 2.1 1.3 5.7 0.4 59 90 101 255 16.2 0.2 16.8 15.7 05/25/2005 19:10:00 4.8 1.2 8.4 1.5 4.7 1.2 8.4 1.1 3.9 1.2 7.6 1.1 110 21 111 255 14.7 0.4 15.7 14.1 05/25/2005 19:20:00 4.2 1.1 8 1.9 4.1 1.1 7.2 1.9 3.3 1.1 6.5 0.4 108 19 88 255 14.1 0 14.4 13.8 05/25/2005 19:30:00 3.1 1 5.3 0.4 3 1 5.7 0.4 2.5 1 4.9 0.4 130 20 127 255 14 0 14.4 13.8 05/25/2005 19:40:00 2.6 0.8 4.9 1.1 2.5 0.8 4.9 1.1 2.3 0.6 4.6 0.7 134 21 131 255 13.9 0 14.4 13.8 05/25/2005 19:50:00 2.6 0.7 4.2 1.1 2.6 0.8 4.6 0.7 2.2 0.6 3.8 0.7 127 22 116 255 13.7 0 14.1 13.5 05/25/2005 20:00:00 3.4 1 6.5 1.5 3.3 1 6.1 0.7 2.8 1 5.7 0.4 132 19 144 255 13.5 0 13.8 13.3 05/25/2005 20:10:00 2.7 0.8 4.9 0.7 2.6 0.8 4.9 0.4 2.1 0.8 4.2 0.4 114 26 126 255 13.4 0 13.8 13.3 05/25/2005 20:20:00 2.5 0.7 4.2 1.1 2.4 0.7 4.2 0.7 1.6 0.8 3.4 0.4 102 23 96 255 13.5 0 13.8 13.3 05/25/2005 20:30:00 2.8 0.8 4.6 0.7 2.7 0.8 4.6 0.4 2.1 0.7 3.4 0.4 124 18 140 255 13.4 0 13.8 13.3 05/25/2005 20:40:00 2.7 0.7 4.6 1.1 2.6 0.7 4.2 0.4 1.9 0.7 3.4 0.4 126 15 114 255 13.3 0 13.8 13 05/25/2005 20:50:00 2.6 0.7 4.6 0.7 2.6 0.7 4.9 1.1 1.9 0.8 4.2 0.4 123 15 125 255 13.2 0 13.5 13 05/25/2005 21:00:00 3.1 0.7 4.9 1.1 3 0.6 4.6 1.1 2.2 0.7 3.8 0.4 114 13 120 255 13.2 0 13.5 13 05/25/2005 21:10:00 2.9 0.6 4.6 1.5 2.9 0.6 4.6 1.5 2 0.7 3.8 0.4 102 12 112 255 13 0.1 13.5 12.7 05/25/2005 21:20:00 2.7 0.5 4.2 1.1 2.6 0.5 4.2 0.7 1.7 0.7 3.4 0.4 95 8 99 255 12.8 0 13.3 12.5 05/25/2005 21:30:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.7 0.6 3.4 0.4 93 10 93 255 12.5 0 12.7 12.2 05/25/2005 21:40:00 3.2 0.5 4.9 1.9 3.2 0.5 4.6 1.5 2.2 0.5 3.4 1.1 88 7 89 255 11.9 0.2 12.5 11.7 05/25/2005 21:50:00 3.2 0.8 5.3 1.1 3.2 0.8 5.3 1.5 2.2 0.8 4.6 0.4 72 12 74 255 11.7 0 12.2 11.7 05/25/2005 22:00:00 3.2 0.7 4.9 1.5 3.2 0.7 4.9 1.5 2.4 0.9 5.3 0.4 66 12 63 255 11.8 0 12.2 11.7 05/25/2005 22:10:00 3.4 0.6 4.9 1.5 3.3 0.6 5.3 1.5 2.5 0.7 4.2 1.1 73 15 56 255 12.1 0 12.5 11.9 05/25/2005 22:20:00 3.4 0.7 5.3 1.9 3.3 0.8 5.3 1.1 2.5 0.7 4.6 1.1 80 13 70 255 12.1 0 12.5 11.9 05/25/2005 22:30:00 3.5 0.8 6.5 1.9 3.5 0.9 6.5 1.5 2.8 0.8 5.3 1.1 74 13 87 255 12.1 0 12.5 11.9 05/25/2005 22:40:00 3.5 0.7 5.7 1.9 3.5 0.8 5.7 1.5 2.7 0.8 5.3 0.4 73 13 105 255 12.1 0 12.5 11.9 05/25/2005 22:50:00 3.9 1.1 6.8 1.1 3.8 1.2 6.5 0.7 3 1.2 6.1 0.4 61 15 66 255 12.1 0 12.5 11.9 05/25/2005 23:00:00 4.6 1.1 8 2.3 4.6 1.1 7.6 1.9 3.6 1 6.5 1.9 52 15 79 255 12.2 0 12.5 12.2 05/25/2005 23:10:00 4.8 0.8 7.2 2.6 4.8 0.8 6.8 3 3.9 1 6.5 1.9 48 13 29 255 12.1 0 12.5 11.9 05/25/2005 23:20:00 4.7 1.1 7.2 1.5 4.6 1 7.6 1.9 3.6 1.1 6.8 0.7 54 17 42 255 12.3 0 12.5 12.2 05/25/2005 23:30:00 5.2 1 7.6 2.6 5.1 1.1 7.6 2.3 4.1 1.1 6.5 1.5 49 17 35 255 12.1 0 12.7 11.7 05/25/2005 23:40:00 5 1.2 8.8 2.3 4.9 1.2 8.8 1.9 4 1.2 8 0.7 52 16 38 255 11.5 0.1 11.9 11.1 05/25/2005 23:50:00 5.3 1.1 8 2.6 5.2 1.1 7.6 2.6 4.2 1.1 8 1.5 40 14 23 255 11.1 0 11.4 11.1 05/26/2005 00:00:00 4.4 1.3 8 1.9 4.4 1.3 8 1.5 3.5 1.3 7.6 0.4 51 20 28 255 11.1 0 11.4 11.1 05/26/2005 00:10:00 3.5 0.7 5.3 1.9 3.5 0.7 4.9 1.9 2.7 0.8 4.6 0.4 78 15 97 255 10.8 0.1 11.1 10.6 05/26/2005 00:20:00 5.4 1.3 8.4 2.3 5.4 1.4 8.4 2.3 4.2 1.3 7.2 1.5 51 15 34 255 10.7 0 10.9 10.6 05/26/2005 00:30:00 4.3 0.9 6.8 1.9 4.3 1 7.2 1.9 3.6 1.1 7.2 0.4 72 17 76 255 10.6 0 10.9 10.6 05/26/2005 00:40:00 5.4 0.9 7.6 3 5.3 1 7.6 2.6 4.4 1.1 6.8 1.5 71 14 71 255 10.5 0 10.6 10.6 05/26/2005 00:50:00 4.9 0.8 7.2 3 4.9 0.8 7.6 2.6 4 1 7.2 0.7 66 15 66 255 10.5 0 10.6 10.6 05/26/2005 01:00:00 4.1 1 7.2 1.5 4 1 6.8 1.5 3.1 1.1 5.7 0.7 73 17 37 255 10.3 0.1 10.6 10.3 05/26/2005 01:10:00 4.3 0.7 6.8 2.6 4.2 0.7 6.5 2.6 3.4 0.9 5.3 0.7 79 13 78 255 10.2 0 10.3 10.1 05/26/2005 01:20:00 3.5 1 6.1 1.5 3.5 1 6.1 1.9 2.8 1 6.1 0.4 62 19 62 255 10.2 0 10.3 10.1 05/26/2005 01:30:00 3.4 0.9 6.5 1.1 3.3 0.9 6.8 0.7 2.7 0.8 4.6 0.7 51 17 31 255 10.2 0 10.3 10.1 05/26/2005 01:40:00 3.1 0.8 5.3 1.9 3 0.8 4.9 1.5 2.4 0.8 5.3 0.7 44 17 35 255 10.2 0 10.3 10.3 05/26/2005 01:50:00 3.6 0.8 5.7 1.5 3.5 0.9 5.7 1.5 2.9 0.8 4.6 1.1 52 17 50 255 10.2 0 10.3 10.1 05/26/2005 02:00:00 4.1 0.7 5.7 2.3 4 0.7 6.1 1.9 3.2 0.7 4.9 1.1 62 15 62 255 10.2 0 10.3 10.1 05/26/2005 02:10:00 4.7 1.2 8.4 1.9 4.7 1.2 8.4 1.9 3.5 1.3 7.2 0.7 83 17 73 255 10.1 0 10.3 10.1 05/26/2005 02:20:00 4.1 1 7.6 1.9 4 1 6.8 1.1 3.2 0.9 5.7 0.7 79 18 80 255 10.3 0 10.6 10.3 05/26/2005 02:30:00 3.5 0.9 5.7 1.5 3.5 1 5.7 1.5 2.7 1 5.3 0.4 76 16 97 255 10.2 0 10.3 10.1 05/26/2005 02:40:00 4 0.7 5.7 2.3 4 0.7 6.1 2.3 3.2 0.9 6.1 1.1 66 13 68 255 10 0 10.1 9.8 05/26/2005 02:50:00 3.6 0.7 5.7 1.9 3.6 0.7 5.3 1.9 2.6 0.8 4.9 0.7 76 14 82 255 9.9 0 10.1 9.6 05/26/2005 03:00:00 4.1 0.8 6.1 1.9 4 0.8 6.5 1.1 3 0.9 5.3 0.4 75 15 55 255 9.6 0 9.8 9.6 05/26/2005 03:10:00 4.7 0.9 6.8 2.6 4.6 0.9 6.8 2.6 3.4 1 6.1 0.7 70 13 64 255 9.5 0 9.6 9.6 05/26/2005 03:20:00 4.3 0.8 6.8 2.3 4.3 0.9 7.2 1.5 3.3 0.8 6.1 1.5 59 15 73 255 9.7 0 9.8 9.6 05/26/2005 03:30:00 3.2 0.7 5.3 1.1 3.1 0.8 4.9 1.5 2.3 0.8 4.2 0.4 63 13 54 255 9.6 0 9.8 9.6 05/26/2005 03:40:00 3.2 0.6 4.9 1.5 3.1 0.6 4.9 1.5 2.5 0.6 4.2 1.1 60 12 55 255 9.4 0 9.6 9.3 05/26/2005 03:50:00 2.4 0.8 4.2 0.7 2.4 0.8 4.2 0.4 1.8 0.7 3.8 0.4 64 12 67 255 9.4 0 9.6 9.3 05/26/2005 04:00:00 2.9 0.8 4.9 1.1 2.8 0.8 4.9 1.1 1.9 0.7 3.8 0.4 69 14 76 255 9.2 0.1 9.3 9 05/26/2005 04:10:00 3.4 0.8 5.3 1.9 3.3 0.8 5.3 1.5 2.5 0.9 4.6 0.7 57 20 72 255 9.2 0.2 9.6 9 05/26/2005 04:20:00 2.1 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.8 0.8 3.8 0.4 77 22 57 255 9.8 0 9.8 9.6 05/26/2005 04:30:00 1.6 0.4 2.6 0.4 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 115 8 95 255 9.2 0.2 9.6 8.8 05/26/2005 04:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 130 9 112 255 8.9 0 9 8.8 05/26/2005 04:50:00 1.6 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1 0.6 2.6 0.4 128 13 108 255 8.5 0 8.8 8.5 05/26/2005 05:00:00 1.9 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.1 0.6 2.6 0.4 66 38 109 255 8.5 0 8.8 8.5 05/26/2005 05:10:00 2.6 0.5 3.8 0.7 2.5 0.6 4.2 0.7 1.9 0.6 3.4 0.4 43 13 43 255 8.7 0 9 8.5 05/26/2005 05:20:00 3 0.5 3.8 1.5 2.9 0.5 3.8 1.1 2 0.7 3.4 0.4 64 17 55 255 9 0 9.3 9 05/26/2005 05:30:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.7 0.7 3.4 0.4 82 10 87 255 9.2 0 9.3 9 05/26/2005 05:40:00 2.9 0.6 4.6 1.5 2.9 0.6 4.6 1.1 1.9 0.8 3.4 0.4 83 10 68 255 9.3 0 9.3 9.3 05/26/2005 05:50:00 2.8 0.6 4.6 0.7 2.7 0.7 4.6 0.4 1.8 0.7 3.8 0.4 88 11 83 255 9.4 0 9.6 9.3 05/26/2005 06:00:00 3.2 0.7 5.3 1.5 3.1 0.8 5.3 1.1 2.2 0.8 4.2 0.4 79 12 78 255 9.6 0 9.6 9.3 05/26/2005 06:10:00 3.2 0.8 4.9 1.5 3.1 0.8 4.9 1.1 2.3 0.8 4.2 0.4 86 13 74 255 9.9 0 10.1 9.6 05/26/2005 06:20:00 3.4 0.8 4.9 1.1 3.4 0.8 4.9 1.1 2.5 0.8 4.6 0.4 107 15 102 255 10 0 10.1 9.8 05/26/2005 06:30:00 2.9 0.9 4.9 0.7 2.9 0.9 4.9 0.4 2.1 0.8 4.6 0.4 115 17 116 255 10.3 0 10.6 10.1 05/26/2005 06:40:00 3 0.7 4.9 1.1 2.9 0.8 4.9 0.4 2.4 0.7 4.6 0.7 110 17 116 255 10.5 0 10.6 10.6 05/26/2005 06:50:00 3.2 0.8 6.1 1.5 3.1 0.8 6.5 1.5 2.7 0.8 4.6 0.7 105 13 98 255 10.6 0 10.9 10.6 05/26/2005 07:00:00 3.3 0.9 5.7 1.1 3.2 0.9 5.7 1.1 2.6 0.9 4.6 0.4 111 18 101 255 10.7 0 10.9 10.6 05/26/2005 07:10:00 2.2 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.7 0.9 3.8 0.4 85 15 83 255 11 0 11.4 10.9 05/26/2005 07:20:00 2.2 0.9 4.2 0.4 2.1 1 4.2 0.4 1.8 0.9 3.8 0.4 92 16 95 255 11.7 0.2 12.2 11.1 05/26/2005 07:30:00 3.4 0.7 4.9 1.5 3.3 0.7 5.3 1.5 3.2 0.8 4.9 1.1 103 12 100 255 12.5 0.3 13.3 12.2 05/26/2005 07:40:00 3.6 0.7 5.3 1.5 3.5 0.7 5.3 1.9 3.2 0.7 4.9 1.1 104 13 92 255 13.3 0.2 14.1 13 05/26/2005 07:50:00 3 0.8 5.3 0.7 3 0.8 5.3 1.1 2.7 0.8 4.9 0.7 99 20 101 255 14.1 0.2 14.9 13.8 05/26/2005 08:00:00 2.9 0.9 4.9 0.7 2.8 1 4.6 0.4 2.4 0.8 4.2 0.7 112 21 87 255 14.4 0 15.2 14.4 05/26/2005 08:10:00 2.8 1 6.1 0.4 2.8 1.1 6.1 0.4 2.4 1 5.3 0.4 102 18 97 255 14.7 0.2 15.5 14.4 05/26/2005 08:20:00 3 0.9 5.3 1.1 2.9 0.9 5.3 0.4 2.6 1 5.3 0.4 85 20 84 255 15.7 0.2 16.3 15.2 05/26/2005 08:30:00 3.7 1 6.1 0.4 3.7 1 6.1 0.4 3.2 1 5.7 0.4 82 17 88 255 15.7 0.1 16.3 15.5 05/26/2005 08:40:00 2.9 1.1 6.1 0.4 2.8 1.1 5.7 0.4 2.3 1.1 4.9 0.4 69 35 97 255 16.4 0.2 16.8 16 05/26/2005 08:50:00 3.5 0.9 5.3 0.7 3.4 1 5.3 0.7 2.9 1.1 5.3 0.4 71 33 30 255 16.4 0.3 17.1 16 05/26/2005 09:00:00 4.5 0.9 6.8 1.9 4.4 0.9 6.5 2.3 3.3 1 6.5 1.1 19 14 18 255 17.5 0.3 17.7 16.8 05/26/2005 09:10:00 4.7 0.8 6.5 2.6 4.7 0.8 6.5 2.6 3.7 1 6.1 0.7 18 14 17 255 16.9 0.2 17.4 16.6 05/26/2005 09:20:00 3.7 1 6.1 1.5 3.6 1 6.1 1.1 2.7 1.1 5.7 0.7 17 19 26 255 17.8 0.3 18.2 17.1 05/26/2005 09:30:00 5.1 1.3 8 1.9 5.1 1.3 8 1.9 4 1.3 6.8 1.1 16 17 4 255 18.3 0 18.8 18 05/26/2005 09:40:00 5.2 1.3 8.4 1.5 5.1 1.3 8 1.1 3.8 1.3 7.2 0.7 14 13 11 255 17.9 0.4 18.5 17.1 05/26/2005 09:50:00 5.6 1.3 8.8 2.3 5.5 1.3 8.8 2.3 4.6 1.5 8.4 1.5 27 14 21 255 16.4 0.3 17.7 16 05/26/2005 10:00:00 5.9 0.9 8 3.4 5.9 0.9 8 3.4 5.1 1 7.6 2.3 36 13 34 255 16.3 0.4 17.4 15.7 05/26/2005 10:10:00 5.6 0.9 7.6 3 5.5 1 7.6 2.6 4.6 1 6.8 2.3 27 14 7 255 18.5 0.6 19.4 17.4 05/26/2005 10:20:00 5.7 1.1 8 2.6 5.6 1.1 8 2.6 4.7 1.2 8 1.9 38 15 40 255 17.9 0.6 19.1 16.8 05/26/2005 10:30:00 6.1 1.3 8.8 2.6 6 1.4 8.8 2.3 4.6 1.3 7.6 1.5 17 12 39 255 16.9 0 17.1 16.8 05/26/2005 10:40:00 5.9 1.2 8.8 2.6 5.9 1.2 8.4 2.3 4.7 1.3 8.4 1.1 35 18 22 255 16.6 0.3 17.1 16 05/26/2005 10:50:00 5.9 1.7 9.9 1.9 5.9 1.8 9.9 1.9 4.8 1.7 8.8 1.5 52 17 48 255 15.3 0.2 16 15.2 05/26/2005 11:00:00 6.3 1.3 9.5 2.6 6.2 1.4 9.5 2.3 5.5 1.5 9.1 1.9 46 16 25 255 15.4 0 15.7 15.2 05/26/2005 11:10:00 6.9 1.3 10.7 4.2 6.8 1.3 11.1 4.2 5.7 1.3 10.3 2.6 27 17 5 255 16 0.2 16.6 15.7 05/26/2005 11:20:00 7.7 1.3 11.1 4.6 7.7 1.3 11.1 4.2 6.3 1.5 10.3 3.4 24 12 33 255 16.6 0 16.8 16.3 05/26/2005 11:30:00 7 1.4 9.5 3.4 7 1.5 9.5 3.4 5.9 1.7 9.5 2.3 33 16 24 255 16.7 0 16.8 16.6 05/26/2005 11:40:00 7.1 1.3 9.9 3.8 7 1.3 9.5 3.4 6.1 1.3 9.1 3 43 15 17 255 16.3 0.2 16.8 16.3 05/26/2005 11:50:00 8 1.7 12.2 4.2 7.9 1.7 12.2 4.2 6.3 1.8 11.8 2.6 24 14 20 255 16.5 0 16.8 16 05/26/2005 12:00:00 7.7 1.6 12.2 3.4 7.7 1.5 11.8 3.4 6.2 1.5 10.3 2.6 26 16 20 255 16.4 0.1 16.8 16 05/26/2005 12:10:00 7.9 1.7 11.8 3 7.8 1.8 11.8 3.4 6.6 1.9 11.1 2.3 40 14 40 255 15.7 0.2 16.3 15.2 05/26/2005 12:20:00 8.1 1.3 10.7 5.3 8 1.3 10.7 4.9 6.7 1.7 10.7 2.6 28 13 45 255 15.1 0.1 15.7 15.2 05/26/2005 12:30:00 7.1 1.3 10.3 4.2 7 1.3 10.3 3.8 5.9 1.5 9.5 3 25 16 21 255 14.8 0.1 15.5 14.6 05/26/2005 12:40:00 7.7 1.5 11.1 4.2 7.6 1.5 11.1 3.8 6.3 1.6 11.1 2.6 27 17 28 255 14.7 0.1 15.2 14.6 05/26/2005 12:50:00 7.8 1.7 12.2 3 7.8 1.7 11.8 3 6.2 1.9 11.5 2.3 20 15 8 255 15 0 15.2 14.6 05/26/2005 13:00:00 8.9 1.9 14.1 4.2 8.8 2 13.7 3.8 6.9 2.1 11.8 2.6 20 13 31 255 15 0 15.5 14.9 05/26/2005 13:10:00 8.4 1.4 11.8 4.2 8.3 1.5 12.2 3.8 6.4 1.9 11.5 1.9 15 15 15 255 14.8 0 15.5 14.6 05/26/2005 13:20:00 8 1.2 11.5 4.9 8 1.3 11.8 5.3 6.6 1.5 11.5 2.6 19 11 2 255 14.9 0 15.5 14.6 05/26/2005 13:30:00 8.4 1.7 13 3.8 8.4 1.7 13 3.8 6 2.1 11.8 1.5 10 13 15 255 14.6 0 15.2 14.4 05/26/2005 13:40:00 8.5 1.8 13.3 4.2 8.5 1.9 13.7 4.2 6.5 2.1 12.2 1.5 14 15 0 255 14.4 0.1 14.9 14.1 05/26/2005 13:50:00 10.4 1.8 17.2 6.5 10.4 1.9 17.2 6.5 8 2.2 15.3 3 14 12 17 255 14 0.1 14.6 13.8 05/26/2005 14:00:00 9.3 1.8 14.1 3.4 9.3 1.9 14.1 3.4 7.1 2.2 12.6 2.6 15 13 27 255 13.9 0 14.4 13.8 05/26/2005 14:10:00 10 1.7 14.5 6.5 10 1.7 14.5 5.7 8.1 1.7 12.6 3.8 18 11 15 255 13.7 0.1 14.1 13.5 05/26/2005 14:20:00 9.7 1.9 14.5 3.4 9.6 1.9 14.1 3.4 7.3 2.2 13 2.3 15 13 14 255 13.5 0 13.8 13.3 05/26/2005 14:30:00 10.5 1.5 14.1 6.8 10.4 1.5 13.7 6.1 8 1.6 12.2 4.6 16 12 24 255 13.2 0.1 13.8 13 05/26/2005 14:40:00 9.2 1.5 13.3 5.7 9.2 1.5 13.7 5.7 7.4 1.8 12.2 3.4 20 10 49 255 13.2 0 13.5 13 05/26/2005 14:50:00 8.7 1.7 14.1 4.9 8.7 1.7 14.1 4.9 6.9 2 13 2.6 20 10 21 255 13.3 0 13.8 13 05/26/2005 15:00:00 8.4 1.3 12.2 5.3 8.4 1.3 12.6 5.7 6.9 1.5 12.6 3 24 12 14 255 13.3 0 13.3 13.3 05/26/2005 15:10:00 8.2 1.4 11.5 4.9 8.1 1.4 11.5 4.6 6.4 1.5 10.7 3 21 13 40 255 13.2 0 13.3 13 05/26/2005 15:20:00 8.8 1.7 12.6 4.2 8.8 1.7 13 4.6 7 1.7 12.6 3.4 22 13 12 255 13.3 0 13.8 13 05/26/2005 15:30:00 9.8 2 14.9 5.3 9.7 2 14.9 4.9 7.7 2.3 14.9 1.9 19 11 44 255 13.9 0.2 14.6 13.5 05/26/2005 15:40:00 8.4 1.8 13.3 4.2 8.4 1.9 13.3 2.6 6.5 2.1 10.7 2.3 16 14 31 255 14.3 0 14.9 14.1 05/26/2005 15:50:00 7.8 1.6 12.6 4.2 7.8 1.7 12.2 4.2 6.2 1.8 11.5 2.6 23 16 28 255 14.2 0 14.9 13.8 05/26/2005 16:00:00 8.9 1.7 14.1 3.8 8.9 1.7 14.1 4.2 7.4 1.9 13 2.3 16 15 21 255 14.3 0 14.9 14.1 05/26/2005 16:10:00 7.4 1.4 11.5 4.2 7.3 1.5 11.1 3.8 6 1.5 10.3 1.9 27 16 38 255 14.4 0 15.2 14.4 05/26/2005 16:20:00 8 1.7 13.7 3.8 8 1.7 13.7 3.8 6.7 2 13 2.3 30 16 8 255 15.7 0.4 16.6 14.6 05/26/2005 16:30:00 9.3 1.8 13.7 4.6 9.2 1.8 13.7 4.9 7.6 1.8 12.2 3.8 24 13 23 255 16.8 0.2 17.4 16.6 05/26/2005 16:40:00 10.2 1.8 15.3 5.3 10.2 1.9 15.6 4.9 8 2.4 14.1 2.3 15 14 28 255 16.4 0.5 17.4 15.7 05/26/2005 16:50:00 9.9 1.8 13.7 4.9 9.8 1.8 13.7 4.9 7.6 2 13 3.4 20 12 39 255 15.5 0 16 15.2 05/26/2005 17:00:00 9.2 1.6 14.1 5.7 9.1 1.6 14.1 5.7 7.6 1.9 13.7 3 26 13 19 255 15.1 0 15.5 14.9 05/26/2005 17:10:00 10.1 1.6 14.9 5.7 10.1 1.6 14.5 6.1 8.2 1.8 12.2 4.2 22 12 19 255 15.7 0.5 16.6 15.2 05/26/2005 17:20:00 8.9 1.7 12.6 4.6 8.9 1.7 13 4.2 6.7 2 11.1 2.3 18 14 4 255 16.6 0.1 17.1 16.3 05/26/2005 17:30:00 8.2 1.3 11.5 3.4 8.2 1.3 11.5 3.8 6.4 1.7 9.9 1.9 16 14 10 255 17.1 0.1 17.4 16.8 05/26/2005 17:40:00 8.5 1.6 13 3.8 8.5 1.6 13 3.4 6.6 1.9 11.1 1.5 13 14 18 255 17 0.3 17.7 16.3 05/26/2005 17:50:00 8.7 1.3 13 5.3 8.7 1.3 13 5.3 7.3 1.6 10.7 3.4 27 14 23 255 15.7 0.3 16.8 15.2 05/26/2005 18:00:00 8.3 1.4 11.8 4.6 8.2 1.4 11.5 4.6 6.8 1.5 10.7 2.3 25 11 25 255 15 0 15.5 14.9 05/26/2005 18:10:00 8.6 1.8 14.1 4.2 8.6 1.8 14.1 4.2 7.2 1.9 13 2.6 27 16 7 255 15 0 15.7 14.9 05/26/2005 18:20:00 8.9 1.4 12.2 4.9 8.8 1.5 12.2 4.6 7 1.7 11.8 3 18 10 0 255 15 0 15.5 14.9 05/26/2005 18:30:00 8.5 1.6 12.2 3.8 8.5 1.7 12.2 3.4 7.2 1.8 11.8 1.9 28 13 22 255 15 0 15.5 14.9 05/26/2005 18:40:00 8.1 1.6 11.5 3.8 8.1 1.7 12.6 3.4 6.9 1.7 11.5 1.9 30 13 42 255 14.8 0.1 15.5 14.6 05/26/2005 18:50:00 8.1 1.6 11.8 4.2 8 1.5 11.8 4.2 6.6 1.5 10.3 3 28 15 27 255 14.5 0 15.2 14.4 05/26/2005 19:00:00 9.2 1.5 14.5 4.9 9.1 1.5 14.9 5.3 7.4 1.7 11.5 3.8 27 16 6 255 14.2 0.2 14.9 13.8 05/26/2005 19:10:00 9 1.3 12.6 5.3 9.1 1.3 12.6 5.7 7.2 1.7 11.5 3 17 12 12 255 13.9 0 14.4 13.8 05/26/2005 19:20:00 9.4 1.4 12.6 4.9 9.4 1.5 12.6 4.6 7.5 2 11.5 2.6 18 12 20 255 13.8 0 13.8 13.5 05/26/2005 19:30:00 8.5 1.5 11.8 3.4 8.4 1.6 12.2 3.4 6.9 1.7 11.5 3 24 14 18 255 13.6 0 13.8 13.5 05/26/2005 19:40:00 8.1 1.6 13 4.6 8 1.6 13 4.2 6.4 1.7 12.2 2.6 23 14 30 255 13.5 0 13.8 13.3 05/26/2005 19:50:00 7.6 1.5 11.5 4.9 7.6 1.5 11.8 4.9 6.3 1.8 11.8 2.6 22 11 20 255 13.3 0 13.5 13 05/26/2005 20:00:00 9 1.7 13.7 4.6 9 1.7 13.7 4.9 7.3 2 13.3 3 23 14 32 255 12.9 0 13.3 12.7 05/26/2005 20:10:00 8.5 1.5 11.8 4.2 8.5 1.5 12.2 3.4 7.1 1.7 12.2 2.6 22 13 24 255 12.7 0 13 12.5 05/26/2005 20:20:00 8.1 1.9 12.6 2.3 8 2 12.6 2.3 6.5 2 11.5 2.3 20 13 37 255 12.5 0 12.7 12.5 05/26/2005 20:30:00 9.1 1.6 12.6 4.9 9.1 1.6 12.6 4.6 7.1 1.9 11.8 0.7 17 11 21 255 12.3 0 12.7 12.2 05/26/2005 20:40:00 10.4 1.7 14.5 6.8 10.3 1.7 15.3 6.5 8.1 2.2 14.5 3.4 18 12 22 255 12 0 12.5 11.9 05/26/2005 20:50:00 9.4 1.7 14.1 4.9 9.3 1.7 14.5 5.3 7.2 1.7 12.6 3.8 20 13 1 255 12 0 12.5 11.9 05/26/2005 21:00:00 9.4 1.5 13 6.1 9.3 1.5 13 5.7 7.9 1.7 11.8 3.8 26 12 40 255 11.9 0 12.5 11.7 05/26/2005 21:10:00 9.4 1.7 13.7 4.6 9.5 1.7 13.7 4.6 7.4 1.9 12.2 3 23 14 17 255 11.6 0 12.2 11.4 05/26/2005 21:20:00 10.1 1.8 14.1 5.7 10 1.8 14.1 4.9 8.3 2.1 13 2.6 22 11 15 255 11.4 0 11.7 11.4 05/26/2005 21:30:00 9.5 1.7 14.5 5.7 9.5 1.7 14.5 5.7 7.3 2.1 13.3 0.7 19 13 26 255 11.1 0 11.7 11.1 05/26/2005 21:40:00 9.5 1.7 13 5.3 9.5 1.7 13.3 4.9 7.4 1.8 13 3.4 22 13 13 255 11.1 0 11.1 11.1 05/26/2005 21:50:00 9.2 1.7 14.1 5.3 9.2 1.7 13.7 5.7 7.3 2.1 12.6 2.6 22 12 33 255 11.1 0 11.1 11.1 05/26/2005 22:00:00 9.8 1.6 14.1 5.7 9.8 1.7 13.7 5.3 7.5 2 13.7 2.6 17 12 21 255 11.1 0 11.1 11.1 05/26/2005 22:10:00 8.7 1.5 14.1 5.7 8.7 1.5 14.1 5.7 6.8 1.7 13.3 3 18 10 11 255 11.1 0 11.4 11.1 05/26/2005 22:20:00 9.6 1.4 13.7 6.1 9.6 1.5 14.1 6.1 7.4 1.8 12.6 3.4 17 11 20 255 11.2 0 11.4 11.1 05/26/2005 22:30:00 8.9 1.5 13 5.3 9 1.5 13.3 4.9 6.9 1.6 11.5 3 18 10 13 255 11.3 0 11.4 11.1 05/26/2005 22:40:00 8.9 1.2 12.2 5.7 8.9 1.2 12.6 5.7 6.9 1.7 11.8 2.3 19 12 1 255 11.1 0 11.4 11.1 05/26/2005 22:50:00 8.2 1.3 12.6 4.2 8.2 1.3 12.6 5.3 6.3 1.5 11.8 3 19 11 5 255 11 0 11.1 10.9 05/26/2005 23:00:00 7.5 1.5 11.5 3.4 7.5 1.5 11.5 3 5.6 1.4 9.5 1.5 18 15 49 255 11.1 0 11.1 10.9 05/26/2005 23:10:00 8 1.6 11.5 4.2 8 1.7 11.8 3.8 6.1 1.7 10.3 1.9 12 13 17 255 10.9 0 11.1 10.9 05/26/2005 23:20:00 7.8 1.3 11.1 4.6 7.7 1.3 10.7 4.9 6.1 1.5 11.1 2.3 21 11 21 255 11.1 0 11.1 11.1 05/26/2005 23:30:00 6.9 1.4 10.7 4.2 6.9 1.5 10.7 3.8 5.4 1.5 10.3 2.3 20 13 16 255 11.1 0 11.1 10.9 05/26/2005 23:40:00 7.2 1.3 11.8 3.8 7.2 1.3 12.2 4.2 6 1.3 9.9 2.6 27 12 12 255 11.1 0 11.4 10.9 05/26/2005 23:50:00 6.7 1.4 9.9 3.4 6.7 1.3 9.5 3.4 5.7 1.5 9.1 1.9 24 13 359 255 11.1 0 11.4 11.1 05/27/2005 00:00:00 6.6 1.3 10.7 3.4 6.6 1.3 10.3 3.4 5.6 1.5 9.9 2.6 36 15 42 255 11.1 0 11.4 11.1 05/27/2005 00:10:00 7.9 1.2 12.2 5.3 7.8 1.2 12.2 5.3 6.4 1.3 10.3 3.4 25 15 32 255 11.1 0 11.1 10.9 05/27/2005 00:20:00 7.5 1.6 12.2 3.8 7.5 1.7 11.8 3.8 6 1.7 10.3 2.3 21 15 21 255 10.8 0 10.9 10.6 05/27/2005 00:30:00 8 1.3 12.6 4.9 8 1.3 12.6 4.9 6.3 1.5 9.9 2.6 23 12 20 255 10.7 0 10.9 10.6 05/27/2005 00:40:00 6.4 1.2 9.5 3 6.4 1.2 9.1 2.6 5.3 1.4 8.4 1.5 39 13 60 255 10.7 0 10.9 10.6 05/27/2005 00:50:00 3.9 0.8 6.1 1.5 3.9 0.8 6.1 1.5 3 1 4.9 0.4 76 17 61 255 10.2 0.4 10.9 9.6 05/27/2005 01:00:00 4.7 0.8 6.5 2.6 4.7 0.8 6.8 2.6 3.8 1 6.5 1.5 77 12 77 255 9.4 0 9.6 9.3 05/27/2005 01:10:00 4.8 0.8 6.5 2.6 4.8 0.7 6.5 2.3 3.9 0.9 6.1 1.5 95 12 94 255 9.4 0 9.6 9 05/27/2005 01:20:00 4.3 0.7 6.1 2.6 4.3 0.7 6.1 2.3 3.5 0.8 5.3 1.1 92 15 93 255 9.6 0 9.8 9.6 05/27/2005 01:30:00 4.9 1 6.8 2.3 4.9 1 6.8 1.9 3.9 1 6.1 1.1 104 15 99 255 10 0 10.1 9.8 05/27/2005 01:40:00 5.3 1 7.6 1.9 5.3 1 7.2 2.3 4.3 1 7.2 1.1 94 17 93 255 10.1 0 10.3 9.8 05/27/2005 01:50:00 5.4 1 7.6 2.3 5.4 1 7.6 2.6 4.6 1 7.6 2.3 83 14 92 255 10.2 0 10.3 10.1 05/27/2005 02:00:00 6.3 1.3 9.5 3.4 6.4 1.2 9.5 3.4 5.1 1.3 8.4 2.3 80 13 61 255 10.3 0.1 10.6 10.3 05/27/2005 02:10:00 5.4 1.1 8 3 5.4 1.1 8 2.6 4.6 1.1 6.5 1.9 76 13 72 255 10.5 0 10.6 10.3 05/27/2005 02:20:00 4.5 1 7.2 2.3 4.5 1 6.8 1.5 3.9 1 6.1 1.5 71 17 73 255 10.5 0 10.6 10.3 05/27/2005 02:30:00 5.2 1.3 9.1 2.6 5.1 1.4 8.8 1.9 4.3 1.2 7.2 1.9 71 14 86 255 10.5 0 10.6 10.3 05/27/2005 02:40:00 5.6 1.1 9.1 3.4 5.5 1.1 9.1 3 4.5 1.2 7.6 1.5 74 18 73 255 10.6 0 10.6 10.6 05/27/2005 02:50:00 6 1.2 8.8 2.6 6 1.1 8.8 3 4.8 1.5 8 1.9 71 16 69 255 11 0.1 11.1 10.6 05/27/2005 03:00:00 5.7 1.1 8 2.6 5.7 1.2 8.8 3 4.8 1.2 8 2.3 63 15 67 255 11.2 0 11.4 11.1 05/27/2005 03:10:00 7.1 1.5 11.1 3 7.1 1.5 10.7 2.6 5.9 1.4 9.1 1.5 67 16 82 255 11.3 0 11.4 11.1 05/27/2005 03:20:00 6.3 1.4 9.5 2.6 6.3 1.5 9.9 3 5.2 1.4 8.4 2.3 65 16 60 255 11.3 0 11.4 11.1 05/27/2005 03:30:00 6.1 1.2 8.8 2.6 6.2 1.2 9.1 3 5 1.5 8.8 1.5 62 16 66 255 11.3 0 11.4 11.1 05/27/2005 03:40:00 7.2 1.8 11.1 2.6 7.3 1.8 11.5 3 6.1 1.8 10.7 1.9 65 15 68 255 11.5 0.1 11.7 11.4 05/27/2005 03:50:00 6.4 1.2 9.5 2.3 6.3 1.3 9.9 2.6 5.6 1.2 8.8 2.6 68 18 50 255 11.7 0 11.9 11.7 05/27/2005 04:00:00 6.2 1.3 10.3 3 6.2 1.4 11.1 3 5 1.3 8.8 2.3 58 19 80 255 11.7 0 11.7 11.7 05/27/2005 04:10:00 6.7 1.5 10.7 3 6.8 1.4 10.7 3.4 5.5 1.5 9.9 2.3 68 17 64 255 11.7 0 11.7 11.7 05/27/2005 04:20:00 6.5 1.5 10.3 2.6 6.5 1.5 10.3 3 5.3 1.5 9.5 1.1 69 18 102 255 11.7 0 11.7 11.7 05/27/2005 04:30:00 6.6 1.4 10.3 2.6 6.7 1.3 10.3 3.4 5.4 1.2 8.8 2.6 63 15 58 255 11.6 0 11.7 11.4 05/27/2005 04:40:00 7.1 1.5 10.7 3.8 7.1 1.5 10.3 3.8 5.9 1.4 9.1 2.6 60 16 73 255 11.6 0 11.7 11.4 05/27/2005 04:50:00 6.4 1.2 9.5 3.4 6.4 1.3 9.5 3.4 5.1 1.3 8 2.6 52 16 33 255 11.7 0 11.7 11.7 05/27/2005 05:00:00 6.1 1.6 10.3 1.9 6.1 1.6 10.7 2.6 5 1.5 9.1 1.9 53 16 43 255 11.7 0 11.7 11.7 05/27/2005 05:10:00 5.8 1.2 9.5 2.6 5.8 1.2 9.1 2.6 4.7 1.2 8 2.3 49 14 34 255 11.6 0 11.7 11.7 05/27/2005 05:20:00 6.2 1.6 10.7 1.9 6.1 1.6 10.7 1.9 5 1.6 9.5 1.5 49 16 37 255 11.6 0 11.7 11.7 05/27/2005 05:30:00 4.7 1.6 9.9 1.9 4.7 1.6 9.9 1.5 4.1 1.5 8.8 1.1 64 19 56 255 11.7 0 11.7 11.7 05/27/2005 05:40:00 4.2 1.2 7.2 1.1 4.3 1.2 7.2 1.1 3.6 1.2 7.6 1.1 82 17 94 255 11.8 0 11.9 11.7 05/27/2005 05:50:00 5 1.2 7.6 2.3 5.1 1.1 8 2.6 4.3 1.2 7.6 1.5 80 17 77 255 11.8 0 11.9 11.7 05/27/2005 06:00:00 5.1 1.1 7.6 2.3 5.1 1 7.6 2.6 4.3 1.1 6.8 1.9 77 19 71 255 11.7 0 11.9 11.7 05/27/2005 06:10:00 5.8 1.5 9.9 2.3 5.8 1.5 10.3 2.6 5 1.4 8.4 1.9 59 18 40 255 12.5 0.3 13 11.7 05/27/2005 06:20:00 6.5 1.3 9.5 2.6 6.5 1.4 9.9 3 5.6 1.3 9.5 2.6 46 13 41 255 13.1 0.2 13.5 12.7 05/27/2005 06:30:00 6 1.2 9.1 2.6 6 1.3 8.8 2.3 5 1.3 8.4 2.3 52 17 60 255 12.7 0 13 12.5 05/27/2005 06:40:00 5.7 1.2 9.5 2.6 5.7 1.3 9.5 3 4.6 1.5 8.8 1.9 62 15 58 255 12.5 0 12.7 12.5 05/27/2005 06:50:00 6 1.6 10.3 2.3 6 1.6 9.9 2.3 5 1.5 9.1 1.9 52 16 59 255 12.5 0 12.7 12.5 05/27/2005 07:00:00 4.6 1.3 7.6 1.9 4.7 1.3 7.6 1.9 3.9 1.2 7.2 0.7 72 24 69 255 12.7 0 12.7 12.5 05/27/2005 07:10:00 4 0.8 6.1 1.9 4 0.9 6.1 1.5 3.5 0.8 6.1 1.5 100 14 129 255 12.7 0 12.7 12.5 05/27/2005 07:20:00 4.1 1.3 6.5 0.4 4.2 1.2 6.8 0.4 3.6 1.2 6.1 0.4 80 28 96 255 12.7 0 12.7 12.5 05/27/2005 07:30:00 4.1 1.2 7.6 1.5 4 1.2 8 1.5 3.7 1.2 7.2 0.7 62 22 70 255 13.1 0 13.3 12.7 05/27/2005 07:40:00 3.3 1.1 6.5 1.1 3.4 1.1 6.5 1.1 2.8 1.2 6.1 0.7 88 17 100 255 13.4 0 13.5 13.3 05/27/2005 07:50:00 3.8 1.1 8.4 1.9 3.9 1.1 8.8 1.9 3.3 1.1 6.8 0.4 86 20 79 255 13.6 0.1 14.4 13.3 05/27/2005 08:00:00 4 1 6.5 1.5 3.9 1 6.5 1.9 3.3 1 6.5 0.7 75 22 108 255 13.9 0.1 14.9 13.8 05/27/2005 08:10:00 4 1 6.5 1.5 4.1 0.9 6.8 1.5 3.6 1 6.8 1.5 68 22 106 255 14.8 0 15.2 14.6 05/27/2005 08:20:00 5.7 1.3 8.8 3 5.7 1.3 8.8 3 5 1.3 8.8 2.6 62 17 63 255 14.3 0.2 15.2 14.1 05/27/2005 08:30:00 6.8 1.5 10.3 3 6.9 1.5 10.7 3.4 5.7 1.5 10.3 2.6 51 16 39 255 14.4 0.1 14.9 14.1 05/27/2005 08:40:00 6.4 1.3 9.9 3 6.3 1.3 9.5 3 5.5 1.3 9.9 2.6 44 14 23 255 14.9 0 15.2 14.9 05/27/2005 08:50:00 6.3 1.5 11.1 2.6 6.4 1.6 10.7 3 5.4 1.6 9.9 1.9 57 17 46 255 15 0 15.7 15.2 05/27/2005 09:00:00 5.9 1.3 8.8 1.9 5.9 1.3 9.1 1.9 5.1 1.1 8.4 2.3 54 22 79 255 15.5 0.4 16.3 14.9 05/27/2005 09:10:00 7.8 1.5 11.8 3.4 7.7 1.5 11.8 4.2 6.6 1.5 11.1 2.3 31 15 10 255 16.2 0.2 17.1 16 05/27/2005 09:20:00 8.7 1.7 12.2 4.9 8.7 1.7 12.2 4.9 7.4 1.9 11.8 2.6 30 15 25 255 16.6 0.3 17.4 16 05/27/2005 09:30:00 8.8 1.5 12.2 3.4 8.7 1.5 11.8 3.4 7.4 1.5 11.1 3.8 34 15 39 255 15.9 0.2 16.6 15.7 05/27/2005 09:40:00 8.3 1.4 12.2 4.9 8.3 1.4 12.2 4.6 6.9 1.7 11.1 3 30 15 28 255 16.7 0.1 17.1 16.6 05/27/2005 09:50:00 8.9 2 14.5 3.8 8.9 2 14.1 4.2 6.9 2.2 11.8 1.9 15 13 20 255 17.4 0.2 18.2 16.8 05/27/2005 10:00:00 9.6 1.5 13.7 5.7 9.5 1.5 13.7 5.7 7.3 1.8 13.7 3 15 12 49 255 18 0.3 18.5 17.4 05/27/2005 10:10:00 9.6 1.5 13.7 4.9 9.6 1.5 13.7 4.6 7.4 1.9 12.2 1.5 15 12 30 255 18.3 0 18.5 18 05/27/2005 10:20:00 9.4 1.4 13 5.3 9.3 1.5 12.6 4.9 7.1 1.8 11.8 2.6 13 12 25 255 18.3 0 18.8 18 05/27/2005 10:30:00 9.4 1.5 13.3 5.7 9.3 1.6 13.3 5.7 7.3 1.9 11.8 2.6 18 12 12 255 18.5 0.1 19.1 18.2 05/27/2005 10:40:00 8.5 1.5 12.6 4.9 8.5 1.5 13 5.3 6.8 1.7 12.2 3.4 25 15 23 255 18.7 0.2 19.1 18.2 05/27/2005 10:50:00 9 1.7 13.3 4.9 9 1.7 13.3 4.6 7.2 1.8 10.7 3 29 17 28 255 18.2 0.2 18.8 17.7 05/27/2005 11:00:00 9.7 1.9 14.1 4.6 9.7 1.9 14.1 4.9 8.1 2.1 13.3 3.4 28 14 23 255 17.6 0 18 17.4 05/27/2005 11:10:00 8.3 1.6 12.6 4.2 8.2 1.7 12.2 4.2 6.7 1.7 11.1 3 25 15 23 255 17.3 0.1 18 16.8 05/27/2005 11:20:00 10 1.7 14.5 5.3 10 1.8 14.1 4.2 8.3 2.2 13 1.9 24 13 20 255 16.3 0.3 17.1 15.7 05/27/2005 11:30:00 9.5 1.8 14.1 4.9 9.4 1.9 14.5 4.9 7.5 2.1 13 2.3 20 14 6 255 15.6 0 16 15.5 05/27/2005 11:40:00 9.2 1.9 14.9 4.6 9.1 1.9 14.9 4.2 7.5 1.9 12.6 2.6 18 11 8 255 15.5 0 15.7 15.5 05/27/2005 11:50:00 9.3 1.5 13.3 5.3 9.3 1.5 13.3 4.9 7.6 1.7 13 3.8 18 15 20 255 15 0 15.5 14.9 05/27/2005 12:00:00 7.2 1.5 11.5 3.8 7.1 1.5 11.1 4.2 5.4 1.7 9.9 1.1 18 16 12 255 15 0 15.5 14.9 05/27/2005 12:10:00 7.2 1.7 13.7 3.4 7.2 1.7 14.1 3.4 5.6 1.8 13 2.3 28 15 19 255 14.9 0 15.2 14.6 05/27/2005 12:20:00 7.6 1.5 11.5 3.8 7.6 1.4 11.8 4.2 6.4 1.3 10.3 3 38 15 44 255 14.5 0.2 15.2 14.4 05/27/2005 12:30:00 6.3 1.2 9.9 3.4 6.3 1.2 9.5 3.4 5.2 1.2 9.1 1.9 38 16 49 255 14.2 0 14.6 14.1 05/27/2005 12:40:00 7.6 1.5 11.1 3 7.6 1.5 11.1 3 6.4 1.4 9.5 3 36 14 32 255 14.1 0.1 14.6 13.8 05/27/2005 12:50:00 7.6 1.7 11.8 3.8 7.5 1.7 11.5 4.2 6.6 1.6 10.3 2.6 44 17 9 255 13.9 0 14.4 13.8 05/27/2005 13:00:00 7.2 1.5 10.7 2.3 7.1 1.6 11.5 2.6 6.1 1.7 9.9 1.9 45 16 38 255 13.9 0 14.4 13.5 05/27/2005 13:10:00 8.1 1.3 11.1 3.8 8.1 1.3 10.7 4.6 6.7 1.5 10.7 3 43 13 40 255 13.8 0 14.4 13.5 05/27/2005 13:20:00 8.9 1.6 13.3 4.6 8.8 1.6 13 4.2 7.5 1.8 11.8 3.8 33 12 41 255 13.8 0 14.4 13.5 05/27/2005 13:30:00 9.1 1.3 13.3 5.7 9.1 1.3 13 6.1 7.5 1.6 13 2.6 28 14 26 255 13.7 0.1 14.4 13.5 05/27/2005 13:40:00 8.8 1.7 13.7 5.3 8.8 1.7 13.7 5.3 7.3 2 13 3 27 15 23 255 13.6 0 14.1 13.5 05/27/2005 13:50:00 8.3 1.7 13.3 4.9 8.3 1.7 13.7 4.9 7 1.9 13.3 2.3 27 13 30 255 13.8 0 13.8 13.5 05/27/2005 14:00:00 7.2 1.3 10.7 4.6 7.1 1.3 10.7 4.6 5.9 1.5 9.9 2.6 24 12 27 255 13.9 0 14.6 13.8 05/27/2005 14:10:00 8.3 1.5 12.6 5.3 8.2 1.5 13 4.9 6.5 1.7 10.7 3 19 13 20 255 14.1 0 14.6 14.1 05/27/2005 14:20:00 8.9 1.5 13.7 4.9 8.9 1.5 13.7 4.9 7.2 1.6 11.8 3 21 11 20 255 14.2 0 14.6 13.8 05/27/2005 14:30:00 8.5 1.6 13 4.6 8.5 1.7 13 4.6 6.5 2.1 11.5 2.3 20 13 20 255 14.4 0 14.9 14.4 05/27/2005 14:40:00 9.1 1.3 12.2 5.7 9.1 1.3 12.2 5.3 7.8 1.5 11.8 3.8 24 11 31 255 14.4 0 14.9 14.4 05/27/2005 14:50:00 9 1.5 13.3 4.6 9 1.5 13.3 4.2 6.9 1.9 12.6 2.3 16 11 25 255 14.4 0 14.9 14.4 05/27/2005 15:00:00 8.7 1.5 13 3.8 8.7 1.6 13 3.8 6.8 1.8 12.2 1.9 17 15 7 255 14.4 0 14.9 14.4 05/27/2005 15:10:00 9 1.4 13.3 4.9 8.9 1.4 13.3 4.9 7.1 1.6 11.5 3.4 25 12 18 255 14.3 0 14.9 14.4 05/27/2005 15:20:00 8.6 1.3 12.2 5.3 8.6 1.3 12.6 4.9 7.2 1.4 10.3 3.4 31 14 12 255 14.2 0 14.6 14.1 05/27/2005 15:30:00 9 1.6 13.3 4.2 9 1.6 13.3 4.6 7.7 1.8 12.6 3.8 28 13 42 255 14.4 0 14.9 14.4 05/27/2005 15:40:00 8.3 1.4 11.1 4.2 8.2 1.5 11.1 3.8 7 1.6 11.8 3.4 27 13 357 255 14.5 0 15.2 14.4 05/27/2005 15:50:00 8.6 1.9 15.3 4.6 8.6 2 15.3 4.9 6.7 1.9 12.2 2.6 22 12 26 255 14.4 0 14.9 14.4 05/27/2005 16:00:00 8.4 1.6 12.2 3.8 8.4 1.6 12.6 4.2 7.1 1.7 12.2 2.6 27 11 22 255 14.2 0 14.6 14.1 05/27/2005 16:10:00 7.7 1.7 11.8 2.3 7.7 1.7 11.5 2.3 6.4 1.7 11.1 2.3 23 15 20 255 14.2 0 14.6 14.1 05/27/2005 16:20:00 8 1.8 12.2 4.2 8 1.8 12.2 3 6.8 1.8 12.6 2.6 31 12 35 255 14.3 0 14.6 14.4 05/27/2005 16:30:00 8.3 1.2 11.5 4.9 8.2 1.2 11.5 4.9 7 1.3 10.3 3.8 30 12 50 255 14 0 14.6 13.8 05/27/2005 16:40:00 7.2 1.2 10.3 3.4 7.2 1.2 10.3 3.4 6.1 1.3 9.1 2.6 34 12 33 255 13.9 0 13.8 13.8 05/27/2005 16:50:00 6.8 1.3 11.1 3.8 6.7 1.3 10.7 3.8 5.8 1.3 10.7 3 30 12 39 255 13.9 0 14.1 13.8 05/27/2005 17:00:00 5.9 1.6 11.8 3 5.9 1.6 11.5 2.6 4.8 1.2 9.1 2.3 34 17 14 255 13.9 0 14.4 13.8 05/27/2005 17:10:00 7.2 1.3 10.3 4.2 7.1 1.3 10.3 4.2 5.8 1.5 10.7 2.6 27 14 11 255 13.9 0 14.4 13.8 05/27/2005 17:20:00 6.1 1.3 9.9 3.4 6.1 1.3 10.3 3.4 5.1 1.3 8.8 2.3 35 15 50 255 13.9 0 14.4 13.8 05/27/2005 17:30:00 6.4 1.7 10.7 2.6 6.3 1.7 10.3 2.3 5.1 1.4 8.8 1.5 35 17 33 255 14 0 14.6 13.8 05/27/2005 17:40:00 7.7 1.5 12.6 2.6 7.7 1.6 13 2.3 6.3 1.7 10.3 1.9 27 16 21 255 14.1 0 14.6 14.1 05/27/2005 17:50:00 7.3 1.8 11.1 3 7.3 1.9 11.8 2.6 5.6 1.9 9.9 1.9 21 14 27 255 14.1 0 14.4 13.8 05/27/2005 18:00:00 6.7 1.7 11.5 3 6.7 1.7 11.5 2.6 5.1 1.7 9.1 1.5 19 14 4 255 13.9 0 14.4 13.8 05/27/2005 18:10:00 6.6 1.3 9.1 3.4 6.6 1.3 9.5 3.4 5.1 1.5 9.1 1.9 17 13 31 255 13.9 0 14.4 13.8 05/27/2005 18:20:00 7.6 1.7 11.8 3.4 7.5 1.7 12.2 3.4 5.9 1.9 10.7 1.9 20 12 21 255 13.9 0 14.4 13.8 05/27/2005 18:30:00 7.4 1.4 10.7 3.8 7.3 1.4 11.1 4.2 6 1.6 10.7 2.6 22 13 29 255 13.9 0 14.4 13.8 05/27/2005 18:40:00 7.1 1.8 12.2 3 7 1.9 12.2 2.3 5.2 1.6 10.3 1.9 21 15 32 255 13.9 0 14.4 13.8 05/27/2005 18:50:00 7.7 2 11.8 3 7.6 2 11.8 3 6.6 1.7 11.1 2.3 25 15 35 255 13.9 0 14.4 13.8 05/27/2005 19:00:00 6.9 1.6 10.3 3 6.8 1.6 9.9 3 5.5 1.7 9.5 0.7 26 16 31 255 13.9 0 14.4 13.8 05/27/2005 19:10:00 7.3 1.1 10.3 4.2 7.2 1.1 10.3 3.8 5.6 1.4 9.5 1.1 18 15 27 255 13.7 0 14.4 13.5 05/27/2005 19:20:00 7.3 1.9 12.6 3.8 7.3 1.9 12.6 3.8 6.1 2.1 12.6 2.3 31 15 36 255 13.7 0 14.1 13.5 05/27/2005 19:30:00 7.2 1.5 11.1 4.6 7.2 1.5 11.5 4.6 6 1.5 10.3 2.6 30 15 41 255 13.7 0 14.1 13.5 05/27/2005 19:40:00 8.9 1.3 13 6.1 8.8 1.3 13.3 5.3 7.2 1.6 12.2 3 28 13 24 255 13.6 0 14.1 13.5 05/27/2005 19:50:00 8.4 1.7 13 4.6 8.3 1.7 12.6 3.8 6.6 1.9 12.2 2.3 24 15 10 255 13.5 0 13.8 13.3 05/27/2005 20:00:00 8.1 2 14.5 2.6 8 2 14.1 2.6 6.5 2.2 13 1.9 20 15 2 255 13.3 0 13.8 13 05/27/2005 20:10:00 9.1 1.9 14.1 4.2 9.1 2 14.5 4.2 7.1 2.4 13.3 2.6 20 13 18 255 13.1 0 13.5 13 05/27/2005 20:20:00 9.3 1.7 14.1 5.3 9.3 1.7 13.7 5.7 7.2 2 12.6 3 20 12 6 255 12.8 0 13.3 12.7 05/27/2005 20:30:00 8.2 1.7 13 4.6 8.2 1.8 13 4.9 6.6 1.9 12.2 2.6 27 15 14 255 12.6 0 13 12.5 05/27/2005 20:40:00 7.3 1.4 11.5 3.8 7.2 1.5 11.5 3.8 5.9 1.4 9.9 2.6 29 15 42 255 12.3 0 12.7 12.2 05/27/2005 20:50:00 8.4 1.6 13 4.9 8.3 1.6 13 4.6 6.6 1.7 12.2 2.6 32 14 31 255 12.3 0 12.5 12.2 05/27/2005 21:00:00 8.6 1.8 13.3 4.6 8.6 1.9 13.3 4.6 6.9 1.8 11.8 3.4 35 12 39 255 12.3 0 12.2 12.2 05/27/2005 21:10:00 7.6 1.3 12.2 4.9 7.5 1.3 11.8 4.9 6.4 1.5 11.8 3.4 40 12 32 255 12.3 0 12.2 12.2 05/27/2005 21:20:00 9.3 1.4 13.3 5.3 9.3 1.4 13.7 5.7 7.9 1.7 12.6 4.2 36 13 43 255 12.3 0 12.2 12.2 05/27/2005 21:30:00 9 1.4 13.7 5.7 9 1.5 13.7 5.7 7.8 1.3 11.8 4.6 36 12 37 255 12.3 0 12.2 12.2 05/27/2005 21:40:00 8.1 1.6 12.2 4.2 8 1.7 12.2 4.2 6.9 1.6 11.5 3.8 38 12 36 255 12.2 0 12.2 11.9 05/27/2005 21:50:00 8.4 1.7 14.5 4.6 8.4 1.7 14.1 4.6 6.9 1.7 13.3 2.6 31 15 34 255 12.3 0 12.2 12.2 05/27/2005 22:00:00 8.5 1.7 14.1 3.8 8.5 1.7 14.5 4.2 7.1 1.8 14.1 2.6 37 15 33 255 12.2 0 12.2 11.9 05/27/2005 22:10:00 9.8 1.8 15.3 5.3 9.8 1.8 15.3 5.7 8.1 2.1 13 3.4 24 13 17 255 12.3 0 12.5 12.2 05/27/2005 22:20:00 8.4 1.5 12.6 4.6 8.4 1.5 12.6 4.2 7.2 1.6 11.1 3.8 30 13 20 255 12.3 0 12.5 12.2 05/27/2005 22:30:00 9.2 1.6 13.7 5.3 9.2 1.6 13.7 4.9 7.9 1.7 13 3.8 33 12 22 255 12.3 0 12.2 12.2 05/27/2005 22:40:00 9.3 1.7 13.3 4.9 9.3 1.7 14.1 4.6 8.1 1.7 12.2 4.2 39 13 24 255 12.3 0 12.5 12.2 05/27/2005 22:50:00 9.1 1.5 13 5.7 9.1 1.5 13.3 5.7 7.8 1.6 12.6 3.8 35 12 70 255 12.3 0 12.2 12.2 05/27/2005 23:00:00 9.7 1.6 14.1 6.1 9.7 1.6 14.1 6.1 8.1 1.7 12.6 4.2 35 12 30 255 12.1 0 12.2 11.9 05/27/2005 23:10:00 8.1 1.5 12.2 4.2 8 1.5 12.2 3.8 6.9 1.5 11.1 3.4 36 12 52 255 11.8 0.1 12.2 11.7 05/27/2005 23:20:00 9.7 1.7 14.5 5.3 9.7 1.8 14.9 4.9 8.3 1.8 13.3 4.2 34 12 31 255 11.7 0 11.9 11.7 05/27/2005 23:30:00 9.2 2 14.9 4.2 9.1 2 14.5 4.9 7.8 2 13.3 3.4 29 12 25 255 11.7 0 11.9 11.7 05/27/2005 23:40:00 9.8 1.5 16.1 6.1 9.7 1.5 15.3 6.1 8.1 1.5 12.2 3.4 33 11 55 255 11.7 0 11.9 11.7 05/27/2005 23:50:00 9.1 1.5 13.3 5.3 9.1 1.6 13.3 5.3 7.6 1.5 12.2 3.8 34 12 26 255 11.7 0 11.9 11.7 05/28/2005 00:00:00 8.9 1.7 14.1 4.6 8.9 1.7 14.5 4.9 7.3 1.8 14.1 3.4 31 13 28 255 11.7 0 11.9 11.7 05/28/2005 00:10:00 8.5 1.6 14.9 4.2 8.5 1.7 14.9 3.4 7.3 1.6 12.6 3.4 27 12 12 255 11.7 0 11.9 11.7 05/28/2005 00:20:00 7.7 1.6 12.6 3.8 7.7 1.6 12.6 3.4 6.2 1.5 10.7 3.4 23 11 17 255 11.7 0 11.7 11.7 05/28/2005 00:30:00 8.4 1.4 12.6 4.9 8.4 1.5 12.2 4.9 7 1.5 11.1 2.6 26 12 15 255 11.6 0 11.7 11.7 05/28/2005 00:40:00 7.4 1.3 10.3 3.8 7.3 1.4 10.3 3 5.7 1.7 9.9 1.9 17 13 14 255 11.5 0 11.7 11.4 05/28/2005 00:50:00 6.7 1.3 10.3 3.8 6.7 1.3 10.7 3.8 5.1 1.6 9.5 1.9 14 11 16 255 11.3 0 11.7 11.1 05/28/2005 01:00:00 6.9 1.2 11.8 4.2 6.9 1.2 11.8 3.8 5.3 1.5 9.9 2.3 15 12 34 255 11.2 0 11.4 11.1 05/28/2005 01:10:00 8.6 1.4 11.8 3.4 8.5 1.4 12.2 3 6.7 1.8 11.8 1.9 16 11 32 255 11.3 0 11.4 11.1 05/28/2005 01:20:00 7.5 1.3 11.8 4.2 7.4 1.3 12.2 4.2 5.7 1.5 10.3 1.9 19 14 11 255 11.2 0 11.4 11.1 05/28/2005 01:30:00 6.9 1.1 9.9 3.8 6.8 1.1 9.9 4.2 5.5 1.1 8.8 2.6 28 14 13 255 11.3 0 11.4 11.1 05/28/2005 01:40:00 7.2 1.2 11.1 4.6 7.1 1.3 10.7 4.6 6.1 1.3 9.5 3.4 32 13 27 255 11.3 0 11.4 11.4 05/28/2005 01:50:00 7.3 1.1 10.3 4.6 7.2 1.1 10.3 4.6 6 1.3 9.5 2.6 33 15 35 255 11.4 0 11.7 11.4 05/28/2005 02:00:00 7 1.5 10.7 3.8 7 1.5 10.7 3.8 5.7 1.5 9.9 2.6 48 15 30 255 11.5 0 11.7 11.4 05/28/2005 02:10:00 4.9 1.1 7.6 2.6 4.9 1.1 7.6 2.6 4 1.1 6.8 1.1 75 13 70 255 10.9 0.3 11.7 10.3 05/28/2005 02:20:00 5.6 1.2 8.8 2.3 5.6 1.3 9.1 2.3 4.6 1.2 8.8 2.3 76 15 94 255 10.3 0 10.6 10.3 05/28/2005 02:30:00 5.4 1.1 9.1 2.6 5.4 1.1 8.8 2.6 4.6 1.2 7.6 2.3 69 15 83 255 10.3 0 10.6 10.3 05/28/2005 02:40:00 5.2 1 9.1 2.6 5.1 1 8.8 2.3 4.3 1.1 8.4 1.9 75 14 68 255 10.3 0 10.3 10.3 05/28/2005 02:50:00 5.6 1.2 8.8 2.6 5.7 1.1 8.8 3 4.5 1.2 8 1.5 69 17 44 255 10.2 0 10.3 10.1 05/28/2005 03:00:00 4.7 1.1 7.6 2.6 4.7 1.2 7.6 2.3 3.7 1.1 6.1 1.1 76 18 73 255 10.2 0 10.3 10.1 05/28/2005 03:10:00 4.7 0.9 7.2 2.3 4.7 1 7.2 2.3 3.8 1.1 7.2 1.1 76 12 63 255 9.9 0 10.1 9.8 05/28/2005 03:20:00 5.3 1 7.6 1.5 5.3 1.1 8 1.1 4.3 1.1 7.6 1.1 77 17 93 255 9.8 0 9.8 9.6 05/28/2005 03:30:00 4.5 1.1 7.6 2.3 4.6 1 7.6 1.9 3.6 1.1 7.2 0.7 71 15 79 255 10 0 10.1 9.8 05/28/2005 03:40:00 3.7 0.7 6.5 1.9 3.7 0.7 6.8 2.3 2.8 0.7 4.6 1.1 79 13 86 255 9.6 0 9.8 9.3 05/28/2005 03:50:00 4.2 1 7.6 1.9 4.2 1 8 1.9 3.4 1 6.1 0.4 84 13 60 255 9.4 0 9.6 9.3 05/28/2005 04:00:00 5 0.9 6.8 2.6 5.1 0.9 7.2 2.6 4.2 1 6.1 1.1 74 14 111 255 9.4 0 9.6 9.3 05/28/2005 04:10:00 4.8 1 7.6 2.6 4.9 1 8 2.3 4.1 1 7.6 1.9 71 13 55 255 9.5 0 9.6 9.3 05/28/2005 04:20:00 4.7 0.8 7.6 3 4.7 0.8 7.6 2.6 3.9 0.9 6.1 1.9 76 12 70 255 9.5 0 9.6 9.3 05/28/2005 04:30:00 4.5 0.8 6.8 2.3 4.5 0.8 7.2 1.9 3.5 0.9 5.7 1.1 82 16 66 255 9.5 0 9.6 9.3 05/28/2005 04:40:00 5.1 1 7.6 2.6 5.1 1 7.6 2.6 4 1.1 6.5 1.1 85 13 87 255 9.6 0 9.6 9.6 05/28/2005 04:50:00 4.8 0.8 6.8 2.6 4.7 0.8 6.8 1.9 3.8 0.9 6.1 1.9 82 15 53 255 9.6 0 9.6 9.3 05/28/2005 05:00:00 4.3 0.6 6.1 2.3 4.3 0.6 5.7 2.3 3.5 0.8 5.7 1.1 80 13 76 255 9.5 0 9.6 9.3 05/28/2005 05:10:00 4.5 0.8 6.8 1.9 4.4 0.8 6.5 1.9 3.6 1 6.5 1.1 77 14 76 255 9.5 0 9.6 9.6 05/28/2005 05:20:00 4.5 0.9 6.8 2.6 4.6 1 7.2 2.3 3.7 1 6.5 1.9 76 13 62 255 9.8 0 10.1 9.6 05/28/2005 05:30:00 3.6 1 6.1 1.9 3.5 0.9 5.7 1.9 2.8 0.9 4.9 0.7 79 17 79 255 10 0 10.1 9.8 05/28/2005 05:40:00 3.5 1.1 6.1 1.1 3.6 1.1 6.1 1.1 2.9 1 6.1 0.7 84 17 90 255 10 0 10.3 9.8 05/28/2005 05:50:00 5.1 1.4 9.5 1.9 5.1 1.4 9.5 1.9 4.4 1.5 9.5 1.5 92 15 85 255 9.9 0 10.1 9.8 05/28/2005 06:00:00 4.5 1.5 8 1.5 4.5 1.4 8 1.5 3.6 1.5 7.6 0.4 88 18 77 255 10 0 10.1 9.8 05/28/2005 06:10:00 4.2 1 6.1 1.9 4.3 1 6.1 1.5 3.4 0.9 5.7 1.1 92 15 88 255 9.8 0.1 10.1 9.6 05/28/2005 06:20:00 4.2 1 6.1 1.5 4.1 1 6.5 1.9 3.5 1 5.7 1.1 87 15 92 255 9.7 0 9.8 9.6 05/28/2005 06:30:00 4.6 1.1 7.2 1.9 4.6 1.1 7.2 1.9 3.6 1.2 6.5 1.1 83 15 68 255 9.8 0 9.8 9.6 05/28/2005 06:40:00 4.9 1.1 7.6 1.9 4.8 1.1 8 1.9 3.8 1.2 6.5 0.7 80 17 71 255 10 0 10.3 9.8 05/28/2005 06:50:00 4.8 1.1 8.4 1.5 4.7 1.1 8 1.9 3.9 1.2 6.8 1.1 83 16 64 255 10.2 0 10.6 10.1 05/28/2005 07:00:00 4.2 1.1 7.6 1.1 4.1 1.1 7.2 1.1 3.3 1 6.8 0.7 86 17 63 255 10.3 0 10.6 10.3 05/28/2005 07:10:00 4.8 1.3 7.6 1.9 4.9 1.3 8.4 1.5 4.1 1.3 7.6 0.4 92 17 101 255 10.4 0 10.6 10.3 05/28/2005 07:20:00 4.8 1.1 7.2 1.5 4.8 1.1 7.2 2.3 3.9 1.1 6.8 1.9 96 16 108 255 10.5 0 10.6 10.6 05/28/2005 07:30:00 5.1 1.2 8 2.3 5.1 1.2 7.6 1.9 4.2 1.2 6.8 1.5 88 17 91 255 10.9 0.1 11.4 10.6 05/28/2005 07:40:00 4.5 1.1 8 1.9 4.5 1.1 8.4 1.9 3.9 1.1 8.4 1.5 76 21 83 255 11.5 0.1 11.9 11.1 05/28/2005 07:50:00 4.3 1.3 7.6 0.4 4.3 1.3 7.6 1.1 3.6 1.2 6.8 0.7 73 20 79 255 12 0 12.2 11.9 05/28/2005 08:00:00 4.5 1.1 7.6 2.3 4.5 1.1 8 2.3 3.7 1.1 6.8 1.1 68 17 59 255 12.3 0.1 12.5 11.9 05/28/2005 08:10:00 4.5 1 6.5 1.5 4.6 1.1 6.8 1.9 4 1 6.5 1.5 67 17 46 255 12.6 0.1 13 12.2 05/28/2005 08:20:00 4.3 1 6.5 1.5 4.2 1 6.8 1.9 3.7 1 5.7 1.5 64 16 51 255 13.3 0.1 13.8 13 05/28/2005 08:30:00 4.4 0.9 6.5 2.3 4.4 0.8 6.8 1.5 3.8 1 6.1 1.1 89 17 93 255 13.8 0 14.1 13.5 05/28/2005 08:40:00 4 1 6.5 1.5 3.9 1 6.5 1.5 3.5 1.1 6.5 0.7 102 18 100 255 13.8 0 14.4 13.5 05/28/2005 08:50:00 4.7 1.3 8 1.5 4.7 1.3 8.4 1.1 4.2 1.2 7.2 1.5 85 22 44 255 13.8 0 14.6 13.5 05/28/2005 09:00:00 6.5 1.5 11.1 3 6.5 1.4 10.7 3 5.4 1.3 8.4 2.3 52 20 51 255 14.2 0.1 14.9 13.8 05/28/2005 09:10:00 8.4 1.7 13 3.8 8.4 1.7 13.3 3.8 6.8 1.7 11.5 2.6 48 17 47 255 14.1 0.1 14.9 13.8 05/28/2005 09:20:00 8.4 1.7 13.3 4.6 8.4 1.7 13 3.8 7.1 1.6 11.5 3.8 38 15 39 255 14 0 14.6 13.8 05/28/2005 09:30:00 8.7 1.7 13.7 4.6 8.6 1.7 13.3 4.2 7.2 1.9 13 3 40 15 40 255 14.3 0.1 15.2 14.1 05/28/2005 09:40:00 7.4 1.6 11.8 3.8 7.4 1.7 12.2 3.4 6.2 1.6 11.5 2.6 47 17 25 255 15 0.3 16 14.6 05/28/2005 09:50:00 8 2 13.7 3.4 7.9 2 13.7 3.4 6.8 2 13 2.3 32 18 20 255 16.1 0.1 16.6 15.7 05/28/2005 10:00:00 7.7 1.7 12.2 3 7.7 1.7 11.8 3.4 6 1.7 11.1 2.3 21 13 9 255 16.1 0 16.8 16.3 05/28/2005 10:10:00 7.4 1.6 13 3.4 7.3 1.6 12.6 2.6 5.7 1.9 10.7 1.9 16 13 17 255 16.1 0 16.8 16 05/28/2005 10:20:00 7.6 1.7 11.5 2.6 7.5 1.7 11.8 2.6 5.5 1.9 10.3 1.9 15 17 357 255 16.3 0.1 16.8 16 05/28/2005 10:30:00 7.4 1.4 11.5 4.2 7.3 1.5 11.8 4.2 5.9 1.7 12.2 2.3 18 15 22 255 16.1 0 16.3 16 05/28/2005 10:40:00 6.2 1.4 9.9 2.3 6 1.5 10.3 0.7 4.9 1.7 9.1 0.7 24 20 36 255 16.1 0 16.6 16 05/28/2005 10:50:00 6.9 1.6 12.2 3.4 6.9 1.6 11.8 3.4 5.7 1.7 11.5 2.3 34 17 40 255 16 0.1 16.6 15.7 05/28/2005 11:00:00 8.2 1.5 13.3 5.3 8.1 1.5 13.3 4.6 6.9 1.7 13.3 3 34 13 10 255 15.6 0.1 16.3 15.5 05/28/2005 11:10:00 8.1 1.3 11.8 3.8 8 1.4 11.8 3.8 6.6 1.5 11.1 3 34 13 18 255 15.3 0.1 16 15.2 05/28/2005 11:20:00 7.5 1.6 11.8 3.8 7.4 1.7 11.8 3.4 5.8 1.7 11.5 2.3 28 18 24 255 15.2 0.1 15.7 14.9 05/28/2005 11:30:00 7.1 1.5 11.5 3.8 7.1 1.5 11.5 4.2 5.9 1.5 10.7 2.6 34 15 36 255 14.9 0 15.5 14.6 05/28/2005 11:40:00 7 1.5 10.3 3.4 7 1.4 10.3 3.4 5.8 1.4 11.8 3 43 16 27 255 14.7 0.1 15.2 14.6 05/28/2005 11:50:00 7.1 1.4 10.7 3 7 1.4 10.7 3 5.9 1.4 9.9 1.9 42 17 21 255 14.6 0 15.2 14.6 05/28/2005 12:00:00 8.7 1.8 13.7 4.6 8.7 1.9 14.1 3.8 7.4 1.8 12.2 3 43 15 37 255 14.6 0 14.9 14.6 05/28/2005 12:10:00 9.7 1.7 14.5 5.7 9.6 1.7 14.5 4.9 8 1.7 13 3.8 36 12 45 255 14.4 0 14.6 14.4 05/28/2005 12:20:00 8.7 1.8 13.3 4.9 8.7 1.8 13.3 4.9 7.1 1.8 12.2 3.8 32 15 48 255 14.4 0 14.6 14.4 05/28/2005 12:30:00 8.6 1.3 12.2 4.9 8.5 1.3 11.8 4.9 7.4 1.3 10.7 3.4 33 12 30 255 14.2 0 14.6 14.1 05/28/2005 12:40:00 7.7 1.5 13 4.2 7.6 1.5 13 3.8 6.7 1.6 11.8 2.6 30 15 38 255 14 0 14.4 13.8 05/28/2005 12:50:00 6.8 1.6 11.5 3 6.8 1.6 11.5 3 5.7 1.5 11.1 2.3 33 16 31 255 14 0 14.4 13.8 05/28/2005 13:00:00 7.6 1.9 12.6 2.3 7.5 1.9 12.2 3 6.5 1.8 11.5 2.6 35 15 31 255 13.9 0 14.4 13.8 05/28/2005 13:10:00 8.1 1.3 11.5 5.3 8.1 1.5 11.5 4.9 6.7 1.6 11.1 2.6 33 12 40 255 13.7 0 14.4 13.5 05/28/2005 13:20:00 7.4 1 9.9 5.3 7.4 1 9.9 4.6 6.4 1.2 9.9 3.8 33 15 40 255 13.8 0 14.4 13.5 05/28/2005 13:30:00 8 1.2 11.8 5.3 8 1.2 11.8 5.7 7 1.3 11.1 3.8 29 11 44 255 13.8 0 14.4 13.5 05/28/2005 13:40:00 7.5 1 10.3 4.6 7.4 1.1 10.3 4.9 6.3 1.3 9.1 2.6 28 12 22 255 13.9 0 14.4 13.8 05/28/2005 13:50:00 8.4 1.1 11.1 5.7 8.4 1.1 11.5 5.3 6.7 1.6 10.7 3 20 13 17 255 13.9 0 14.4 13.8 05/28/2005 14:00:00 9.2 1.7 13 4.9 9.1 1.7 13.3 4.9 7.1 2.1 12.6 3 16 11 18 255 13.9 0 14.4 13.8 05/28/2005 14:10:00 9.1 1.3 12.2 5.3 9 1.3 12.2 5.3 7 1.7 11.5 3.4 16 10 26 255 13.9 0 14.4 13.8 05/28/2005 14:20:00 8.6 1.3 12.2 6.1 8.6 1.3 12.2 4.6 6.7 1.7 11.8 2.6 17 12 22 255 13.9 0 14.4 13.8 05/28/2005 14:30:00 9.1 1.4 13 5.3 9 1.4 13 5.3 7.2 1.7 11.1 3.4 15 13 18 255 13.9 0 14.4 13.8 05/28/2005 14:40:00 8.6 1.7 13 4.6 8.5 1.7 12.6 4.6 6.6 2 11.5 1.9 18 12 351 255 14.1 0.1 14.6 13.8 05/28/2005 14:50:00 8.2 1.6 13.3 4.9 8.2 1.6 13.7 4.9 6.6 1.7 13 3 19 11 26 255 14.2 0 14.9 14.1 05/28/2005 15:00:00 8.3 1.5 12.6 4.2 8.2 1.5 12.6 4.6 6.5 1.8 11.1 2.6 18 12 16 255 14.3 0 14.9 14.4 05/28/2005 15:10:00 8.1 1.2 11.1 4.9 8.1 1.2 11.1 4.9 6.1 1.5 9.5 2.3 16 13 55 255 14.4 0 14.9 14.4 05/28/2005 15:20:00 8.8 2 13.7 3.4 8.8 2.1 13.7 3.4 6.9 2.3 12.2 1.9 19 15 4 255 14.4 0 14.9 14.4 05/28/2005 15:30:00 8.5 1.6 13.7 4.9 8.4 1.7 13.3 4.6 6.9 1.8 12.2 3 20 11 13 255 14.5 0 14.9 14.4 05/28/2005 15:40:00 8.5 1.7 13 4.6 8.5 1.7 13.3 4.6 6.6 1.8 11.5 2.6 19 14 14 255 14.5 0 14.9 14.6 05/28/2005 15:50:00 8.1 1.6 11.8 3 8 1.7 11.5 3 6.2 1.7 11.5 1.5 19 15 26 255 14.6 0 14.9 14.6 05/28/2005 16:00:00 8.1 1.9 13.7 3.4 8 1.9 14.1 3 6.5 2.1 12.2 1.9 21 14 19 255 14.6 0 14.9 14.6 05/28/2005 16:10:00 8.3 2.1 13 4.2 8.2 2.1 13 3.8 6.9 2.1 12.6 2.6 24 12 37 255 14.6 0 14.9 14.6 05/28/2005 16:20:00 9.2 1.7 13.3 5.3 9.2 1.7 13.3 5.3 7.3 2.1 13 3 22 12 12 255 14.6 0 14.9 14.6 05/28/2005 16:30:00 7.9 1.5 11.5 4.6 7.9 1.5 11.5 4.6 6.4 1.7 11.5 3 21 13 10 255 14.8 0 15.2 14.6 05/28/2005 16:40:00 8.3 1.3 11.8 4.9 8.3 1.3 11.8 4.9 6.3 1.5 10.3 2.3 16 12 15 255 14.9 0 15.2 14.9 05/28/2005 16:50:00 8.5 1.6 12.2 3.4 8.5 1.6 12.2 3.4 6.6 1.8 10.7 2.6 16 13 17 255 14.8 0 15.2 14.9 05/28/2005 17:00:00 7.5 1.3 10.7 3.8 7.4 1.3 10.3 3 5.6 1.7 9.5 1.9 20 14 358 255 14.9 0 15.2 14.9 05/28/2005 17:10:00 7.7 1.4 11.5 4.6 7.7 1.4 11.1 4.6 6.3 1.7 11.1 2.6 23 13 21 255 15 0 15.5 15.2 05/28/2005 17:20:00 7.3 1.2 10.3 3.4 7.2 1.2 10.3 3.4 5.9 1.4 9.5 2.6 25 17 21 255 15.8 0.4 16.8 15.2 05/28/2005 17:30:00 8.3 1.7 13 4.2 8.2 1.7 13.3 4.2 6.9 1.7 11.8 2.6 33 12 42 255 16.1 0 16.8 16 05/28/2005 17:40:00 8.4 1.4 12.2 5.3 8.4 1.4 13 5.3 7 1.8 11.8 3.4 29 15 11 255 16 0.1 16.6 15.7 05/28/2005 17:50:00 8.1 1.6 12.6 4.6 8 1.7 12.2 4.2 6.9 1.5 10.7 3.4 36 14 30 255 15.8 0.1 16.3 15.7 05/28/2005 18:00:00 7.6 1.3 12.2 4.2 7.6 1.4 11.8 4.2 6.4 1.5 10.3 3 33 15 29 255 15.3 0.2 16.3 15.2 05/28/2005 18:10:00 7.5 1.5 11.8 3.4 7.5 1.5 11.5 3 6.4 1.3 10.3 2.3 40 15 38 255 15 0 15.7 14.9 05/28/2005 18:20:00 6.6 1.2 10.7 4.2 6.5 1.3 10.7 4.2 5.6 1.3 9.9 3 34 13 28 255 15 0 15.5 14.9 05/28/2005 18:30:00 6.2 1.2 9.5 2.3 6.1 1.2 9.9 2.6 5 1.2 8.4 2.3 35 17 349 255 15 0 15.7 14.9 05/28/2005 18:40:00 7.1 1.4 11.5 4.2 7 1.5 11.1 3.4 5.8 1.6 9.9 1.9 23 15 6 255 15.1 0 15.7 15.2 05/28/2005 18:50:00 7.2 1.4 12.2 3.8 7.1 1.4 11.8 4.2 5.6 1.5 10.3 1.9 18 13 0 255 15 0 15.7 14.9 05/28/2005 19:00:00 7.1 1.3 10.3 4.2 7.1 1.2 10.7 4.2 5.6 1.5 9.1 2.6 18 13 355 255 14.7 0 15.2 14.6 05/28/2005 19:10:00 8 1.5 12.6 3.4 8 1.5 12.6 3.4 6.3 1.7 12.2 2.6 17 12 15 255 14.6 0 15.2 14.6 05/28/2005 19:20:00 7.8 1.7 12.2 4.2 7.7 1.8 12.2 4.6 5.9 1.9 10.7 1.9 18 12 22 255 14.6 0.1 15.2 14.6 05/28/2005 19:30:00 8.4 1.5 11.8 3.8 8.3 1.6 11.8 3.4 6.3 2 11.1 1.5 15 12 6 255 14.6 0 15.2 14.6 05/28/2005 19:40:00 9.3 1.3 13 6.1 9.3 1.3 13 6.1 7.4 1.7 11.1 2.6 18 12 18 255 14.4 0 14.6 14.4 05/28/2005 19:50:00 7.8 1.6 14.1 3.8 7.8 1.6 14.1 3.4 6.4 1.7 12.2 1.9 23 13 17 255 14.2 0 14.6 14.4 05/28/2005 20:00:00 7.7 1.5 11.5 4.6 7.7 1.5 11.8 4.2 6.1 1.6 9.9 2.3 22 13 18 255 14.2 0 14.6 14.4 05/28/2005 20:10:00 8.3 1.5 12.2 4.6 8.2 1.5 12.6 4.6 6.4 1.6 11.1 2.6 19 17 15 255 14.2 0 14.6 14.1 05/28/2005 20:20:00 8.8 1.9 13.7 3.4 8.8 1.9 13.7 3 6.8 2.2 13.3 1.5 21 14 20 255 14 0 14.6 13.8 05/28/2005 20:30:00 8 1.7 13.3 3.4 7.9 1.7 13.3 3.8 6.3 1.7 11.8 3 26 16 23 255 13.9 0 14.6 13.5 05/28/2005 20:40:00 8.5 1.3 11.5 4.6 8.4 1.3 11.8 4.6 7.1 1.4 11.1 3 29 12 30 255 13.9 0 14.6 13.8 05/28/2005 20:50:00 9.4 1.5 13.3 5.7 9.4 1.5 13.3 5.7 7.8 1.6 12.6 4.6 23 11 23 255 13.9 0 14.6 13.8 05/28/2005 21:00:00 8.2 1.3 12.6 4.9 8.1 1.3 12.6 4.6 6.6 1.5 10.7 3 24 13 30 255 13.7 0 13.8 13.5 05/28/2005 21:10:00 8.2 1.3 13.3 4.2 8.1 1.4 13 4.2 7 1.6 11.1 3 30 12 11 255 13.6 0 13.8 13.5 05/28/2005 21:20:00 7.7 1.1 10.7 4.2 7.6 1.1 11.1 4.6 6.5 1.2 9.9 3.4 32 13 35 255 13.5 0 13.5 13.5 05/28/2005 21:30:00 7.1 1.1 9.5 4.2 7.1 1.1 9.9 3.8 6 1.2 9.5 3.4 37 15 32 255 13.5 0 13.8 13.3 05/28/2005 21:40:00 7.7 1.3 11.5 4.2 7.6 1.3 11.5 4.2 6.6 1.5 10.3 3.4 30 13 25 255 13.5 0 13.5 13.5 05/28/2005 21:50:00 7.3 1.4 10.7 4.2 7.3 1.4 10.7 3.4 6.2 1.5 10.3 2.6 36 13 27 255 13.5 0 13.5 13.3 05/28/2005 22:00:00 7.5 1.4 11.5 4.2 7.4 1.5 11.5 4.2 6 1.5 11.8 2.6 25 14 14 255 13.3 0 13.5 13.3 05/28/2005 22:10:00 7.4 1.6 11.8 4.2 7.4 1.6 11.5 3.8 5.9 1.7 9.9 2.3 19 12 6 255 13.3 0 13.5 13.3 05/28/2005 22:20:00 7.9 1.7 13.7 2.6 7.9 1.8 13.7 2.6 6.3 1.8 13 2.3 21 13 12 255 13.3 0 13.5 13.3 05/28/2005 22:30:00 8.7 1.5 12.6 4.9 8.7 1.6 12.6 4.9 6.9 1.9 11.8 2.6 19 11 26 255 13.3 0 13.3 13.3 05/28/2005 22:40:00 5.9 1 9.1 2.3 5.9 1 8.8 2.6 4.8 1.1 7.6 1.5 39 14 15 255 13.1 0 13.3 13 05/28/2005 22:50:00 5.7 1.2 9.1 3.4 5.6 1.2 9.1 2.6 4.7 1.2 8.4 2.3 43 15 46 255 12.9 0 13 12.7 05/28/2005 23:00:00 6 1.3 9.1 3 5.9 1.3 9.5 2.3 5.1 1.2 9.5 2.3 36 15 56 255 12.9 0 13 12.7 05/28/2005 23:10:00 6.5 1.3 10.7 3.4 6.4 1.4 10.7 3 4.8 1.5 9.1 1.9 15 15 15 255 12.7 0 12.7 12.5 05/28/2005 23:20:00 7.8 1.3 11.5 4.9 7.8 1.3 11.5 4.6 5.7 1.7 10.3 2.3 16 12 39 255 12.3 0 12.5 12.2 05/28/2005 23:30:00 7.2 1.5 11.5 3.8 7.1 1.6 11.5 3.8 5.5 1.6 10.3 1.9 24 14 356 255 12.4 0 12.5 12.5 05/28/2005 23:40:00 6.6 1.4 10.7 3.4 6.4 1.4 10.3 3 5.5 1.4 8.8 2.3 36 15 6 255 12.4 0 12.5 12.5 05/28/2005 23:50:00 7 1.7 11.1 3 6.9 1.7 11.5 3 5.5 1.5 9.5 2.3 32 18 32 255 12.5 0 12.5 12.5 05/29/2005 00:00:00 8.4 1.7 12.6 4.2 8.4 1.7 12.6 4.2 6.2 1.7 11.1 2.3 15 13 4 255 12.7 0 12.7 12.5 05/29/2005 00:10:00 8 1.5 11.5 3.8 8 1.5 11.8 3.8 5.9 1.7 9.9 1.9 14 12 29 255 12.7 0 12.7 12.5 05/29/2005 00:20:00 7.3 1.5 10.7 2.6 7.2 1.5 10.7 1.9 5.2 1.6 9.1 1.9 2 15 19 255 12.4 0 12.7 12.2 05/29/2005 00:30:00 7.1 1.3 10.3 3.8 7 1.3 10.7 3.4 5 1.6 10.3 1.9 4 13 19 255 12.1 0 12.2 11.9 05/29/2005 00:40:00 5.3 1.2 9.5 3 5.2 1.3 9.9 3 3.6 1.5 8.8 0.7 6 17 18 255 11.8 0 12.2 11.7 05/29/2005 00:50:00 6.2 1.4 9.1 3 6.1 1.4 9.1 2.6 4.7 1.4 8.4 1.5 19 16 22 255 11.7 0 11.9 11.7 05/29/2005 01:00:00 4.8 1.1 9.1 2.3 4.7 1.1 8.4 2.3 4 1.1 6.1 1.5 38 16 12 255 12.2 0 12.5 11.9 05/29/2005 01:10:00 1.8 1 4.6 0.4 1.5 1.1 4.6 0.4 1.2 0.8 4.2 0.4 328 45 27 255 11.8 0.1 12.2 11.7 05/29/2005 01:20:00 1.4 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1 0.7 2.6 0.4 205 17 206 255 11.1 0.3 11.7 10.6 05/29/2005 01:30:00 0.7 0.7 3.4 0.4 0.6 0.5 3 0.4 0.6 0.5 2.6 0.4 281 72 313 255 10.3 0.1 10.6 10.1 05/29/2005 01:40:00 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 1.4 0.6 2.6 0.4 129 22 355 255 9.7 0.1 10.1 9.6 05/29/2005 01:50:00 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1 0.5 2.6 0.4 90 45 127 255 9.4 0 9.6 9.3 05/29/2005 02:00:00 2.5 0.6 3.8 1.1 2.4 0.6 3.8 0.7 2.2 0.6 3.8 0.4 128 13 133 255 9.3 0 9.3 9 05/29/2005 02:10:00 2.6 0.7 3.8 0.7 2.5 0.8 3.8 0.4 2.3 0.6 3.8 1.1 123 17 102 255 9.8 0.4 10.6 9 05/29/2005 02:20:00 1.3 0.8 3 0.4 1.1 0.8 3 0.4 1.3 0.7 2.6 0.4 131 23 106 255 10.3 0 10.6 10.3 05/29/2005 02:30:00 2.6 0.7 4.6 1.1 2.6 0.7 4.6 1.1 2.1 0.7 3.8 0.4 87 20 106 255 10.3 0 10.6 10.3 05/29/2005 02:40:00 2.5 0.9 4.6 0.4 2.4 0.9 4.6 0.4 2 0.9 3.8 0.4 88 30 127 255 10.3 0 10.6 10.3 05/29/2005 02:50:00 2.5 0.8 4.2 0.4 2.4 0.9 4.6 0.4 2 0.6 3.8 0.7 74 20 95 255 10.5 0 10.6 10.3 05/29/2005 03:00:00 3.5 1 7.2 0.4 3.4 1 7.2 1.1 2.6 0.9 5.7 0.7 44 17 32 255 10.7 0 10.9 10.6 05/29/2005 03:10:00 4.9 0.9 7.6 2.6 4.8 0.9 7.2 3 3.8 1.2 6.5 1.1 26 19 68 255 10.9 0 11.1 10.9 05/29/2005 03:20:00 4 0.8 6.1 2.3 4 0.9 6.1 1.9 3.2 0.8 5.7 1.5 45 13 43 255 11.1 0 11.1 11.1 05/29/2005 03:30:00 4 0.8 6.5 1.9 4 0.8 6.5 1.9 3.2 0.9 5.7 1.1 55 15 49 255 10.9 0 11.1 10.9 05/29/2005 03:40:00 4.1 0.7 6.1 2.3 4.2 0.7 6.1 1.9 3.3 0.8 5.3 0.7 58 15 49 255 10.7 0 10.9 10.6 05/29/2005 03:50:00 3.8 0.7 5.7 1.9 3.8 0.7 5.7 1.9 3 0.8 5.3 1.1 49 12 52 255 10.7 0 10.9 10.6 05/29/2005 04:00:00 4.2 0.6 6.5 2.3 4.1 0.6 6.5 2.3 3.3 0.7 5.3 1.5 52 16 57 255 10.7 0 10.9 10.6 05/29/2005 04:10:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 2.9 0.6 4.2 1.1 77 10 90 255 10.5 0 10.9 10.3 05/29/2005 04:20:00 3.6 0.7 5.3 1.9 3.6 0.7 5.3 2.3 3 0.8 4.9 0.7 58 15 53 255 10.3 0 10.6 10.3 05/29/2005 04:30:00 3.7 0.9 6.5 1.1 3.8 1 6.5 1.5 3 0.8 5.7 1.5 60 16 45 255 10.5 0 10.6 10.6 05/29/2005 04:40:00 4.2 0.9 6.5 1.9 4.2 1 6.1 1.1 3.4 1.1 5.7 0.7 73 15 60 255 10.6 0 10.6 10.6 05/29/2005 04:50:00 3.4 0.9 5.3 1.1 3.4 1 5.7 1.1 2.8 0.8 5.3 0.7 76 15 90 255 10.6 0 10.9 10.6 05/29/2005 05:00:00 3.8 0.5 5.3 2.6 3.7 0.5 5.3 1.9 3.1 0.6 4.6 1.9 88 12 86 255 10.4 0 10.6 10.3 05/29/2005 05:10:00 3.8 0.7 5.3 1.9 3.8 0.7 5.3 1.9 3.3 0.9 5.3 0.7 86 10 86 255 10.2 0 10.3 10.3 05/29/2005 05:20:00 3.2 0.7 4.9 1.5 3.1 0.8 4.9 1.1 2.6 0.8 4.2 1.5 82 12 91 255 10.3 0 10.3 10.3 05/29/2005 05:30:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.5 2.5 0.8 4.2 0.7 80 15 64 255 10.2 0 10.3 10.1 05/29/2005 05:40:00 3.8 0.7 5.7 1.5 3.7 0.8 6.1 1.9 3.2 0.6 4.9 1.5 89 11 93 255 10.2 0 10.3 10.3 05/29/2005 05:50:00 3.8 0.9 6.1 1.9 3.8 0.9 6.1 1.9 3.1 1 5.7 0.7 86 13 85 255 10.4 0 10.6 10.3 05/29/2005 06:00:00 3.1 0.8 4.9 0.7 3.1 0.8 4.6 0.7 2.7 0.7 5.3 1.5 90 16 87 255 10.5 0 10.6 10.6 05/29/2005 06:10:00 2.6 0.9 4.6 0.4 2.6 0.9 4.2 0.4 2 0.9 4.6 0.4 82 18 95 255 10.4 0 10.6 10.3 05/29/2005 06:20:00 2.6 1.1 6.1 0.4 2.5 1.2 6.1 0.4 2.1 1 5.7 0.4 77 21 73 255 10.3 0 10.6 10.3 05/29/2005 06:30:00 3.9 1.4 6.8 0.7 3.9 1.5 6.8 0.4 3 1.4 6.1 0.4 65 27 64 255 10.5 0.1 10.9 10.3 05/29/2005 06:40:00 4.6 1.1 8.8 1.5 4.6 1.1 8.4 2.3 3.6 1.3 7.6 1.5 55 17 45 255 10.9 0 11.1 10.9 05/29/2005 06:50:00 3.7 0.8 6.1 1.9 3.7 0.9 6.1 1.5 2.9 0.7 5.3 1.5 47 16 7 255 11 0 11.1 10.9 05/29/2005 07:00:00 5.3 1.2 8 2.3 5.2 1.2 7.6 2.3 4.2 1.2 7.6 0.7 40 15 22 255 11.3 0.1 11.7 11.1 05/29/2005 07:10:00 5.2 1 8 3 5.2 1 8.4 2.6 4.4 1 6.8 2.3 34 14 15 255 11.7 0 11.9 11.7 05/29/2005 07:20:00 5.8 1.3 9.1 3 5.7 1.3 8.8 2.6 4.7 1.3 8 1.9 27 13 35 255 12 0 12.2 11.9 05/29/2005 07:30:00 4.3 1 6.8 2.3 4.2 1 6.5 1.9 3.6 1.1 6.1 1.1 25 12 40 255 12.3 0 12.5 12.2 05/29/2005 07:40:00 2.8 0.7 4.9 1.1 2.7 0.7 4.6 1.1 2.1 0.8 4.6 0.4 44 17 40 255 12.4 0 12.5 12.2 05/29/2005 07:50:00 3.3 0.8 5.7 1.5 3.3 0.8 5.7 0.7 2.5 0.9 4.9 0.4 27 17 51 255 12.4 0 12.5 12.5 05/29/2005 08:00:00 4.3 1.2 7.6 1.5 4.3 1.2 7.2 1.9 3.6 1 5.7 1.1 51 17 32 255 12.5 0 12.5 12.2 05/29/2005 08:10:00 3.3 0.8 5.3 0.7 3.3 0.8 5.3 1.1 2.6 0.8 4.9 0.4 42 20 53 255 12.3 0 12.5 12.2 05/29/2005 08:20:00 4.5 1.6 8.4 0.7 4.4 1.6 8.8 0.4 3.7 1.5 7.6 1.1 23 15 23 255 12.5 0 12.7 12.5 05/29/2005 08:30:00 3.8 1.4 8 0.4 3.7 1.5 7.6 0.4 2.8 1.2 6.1 0.4 4 19 28 255 12.6 0 12.7 12.5 05/29/2005 08:40:00 2.3 1.1 5.7 0.4 2 1.3 5.7 0.4 1.3 1 4.6 0.4 351 22 340 255 12.7 0 12.7 12.5 05/29/2005 08:50:00 1.5 0.7 3.8 0.4 1.2 0.9 3.4 0.4 1.1 0.6 2.6 0.4 4 32 22 255 12.9 0.1 13 12.7 05/29/2005 09:00:00 2.2 0.7 3.4 0.4 2 0.8 3.4 0.4 1.4 0.7 3 0.4 7 19 358 255 13.2 0 13.3 13 05/29/2005 09:10:00 1.8 0.5 3 0.4 1.5 0.6 3 0.4 1.5 0.6 3 0.4 316 19 278 255 13.2 0 13.3 13 05/29/2005 09:20:00 2 0.4 3 1.1 1.8 0.4 3 0.4 1.9 0.4 2.6 0.7 313 15 294 255 12.9 0 13.3 12.7 05/29/2005 09:30:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 324 27 302 255 12.9 0 13.3 12.7 05/29/2005 09:40:00 1.2 0.7 3 0.4 0.9 0.6 3 0.4 1 0.6 2.6 0.4 331 22 312 255 13.5 0.2 14.4 13 05/29/2005 09:50:00 1.6 0.7 4.2 0.4 1.3 0.7 3.4 0.4 1.3 0.6 2.6 0.4 307 38 322 255 14.1 0.3 15.2 13.8 05/29/2005 10:00:00 1.8 0.7 3.8 0.4 1.5 0.8 3.8 0.4 1.5 0.7 4.2 0.4 304 27 288 255 14.4 0.2 15.2 14.1 05/29/2005 10:10:00 0.9 0.6 2.6 0.4 0.7 0.6 2.3 0.4 0.9 0.6 2.3 0.4 18 35 19 255 14.2 0.1 14.9 14.1 05/29/2005 10:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 351 22 343 255 14.3 0 14.6 14.1 05/29/2005 10:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 62 58 345 255 14.5 0 14.9 14.4 05/29/2005 10:40:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 331 36 323 255 15 0.2 15.7 14.6 05/29/2005 10:50:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.1 0.5 2.3 0.4 46 35 40 255 15 0 15.7 14.6 05/29/2005 11:00:00 1.1 0.6 3 0.4 0.8 0.6 2.6 0.4 0.9 0.6 3 0.4 4 35 350 255 14.8 0 15.5 14.6 05/29/2005 11:10:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.6 2.6 0.4 15 22 357 255 15.1 0.1 15.7 15.2 05/29/2005 11:20:00 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 1 0.5 2.3 0.4 62 33 40 255 15.2 0.1 15.7 15.2 05/29/2005 11:30:00 1.5 1 4.2 0.4 1.3 1 3.8 0.4 1.3 0.9 3.8 0.4 34 33 26 255 15.3 0 16 15.2 05/29/2005 11:40:00 2.4 0.7 4.6 0.7 2.1 0.9 4.6 0.4 2 0.8 4.2 0.4 348 22 326 255 15.7 0.2 16.3 15.5 05/29/2005 11:50:00 2.7 0.8 5.3 1.1 2.5 0.9 5.3 0.7 2.3 0.8 4.6 0.7 1 38 294 255 16.3 0.1 16.8 16 05/29/2005 12:00:00 2 0.7 4.2 0.4 1.6 0.7 3.8 0.4 1.7 0.7 3.8 0.4 311 28 328 255 16.6 0.2 17.4 16.3 05/29/2005 12:10:00 1.7 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1.4 0.7 3 0.4 37 28 49 255 17.3 0 17.4 16.8 05/29/2005 12:20:00 1.9 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 320 49 11 255 17.5 0 17.7 17.1 05/29/2005 12:30:00 2.6 0.8 4.9 0.4 2.4 0.8 4.6 0.4 2.3 0.9 4.6 0.4 319 26 290 255 17.1 0.3 17.7 16.8 05/29/2005 12:40:00 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.7 0.7 3.4 0.4 315 28 331 255 16.8 0 17.4 16.8 05/29/2005 12:50:00 2.7 1.2 6.1 0.4 2.3 1 5.3 0.4 2.3 1.2 5.3 0.4 333 22 319 255 17.3 0.1 17.7 16.8 05/29/2005 13:00:00 2.7 1 4.6 0.4 2.2 1 4.2 0.4 2.2 1 4.2 0.4 339 22 344 255 17.2 0 17.4 16.8 05/29/2005 13:10:00 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 1.6 0.8 3.4 0.4 341 22 337 255 17.2 0 17.7 16.8 05/29/2005 13:20:00 1.3 0.7 3 0.4 1.1 0.7 2.6 0.4 1.2 0.7 3 0.4 328 35 337 255 17.5 0 18 17.1 05/29/2005 13:30:00 1.4 1 3.8 0.4 1.2 1 3.8 0.4 1.3 0.9 3.4 0.4 321 69 340 255 18.2 0.5 19.4 17.4 05/29/2005 13:40:00 2.4 0.7 3.8 0.4 2.1 0.8 4.2 0.4 1.9 0.8 3.4 0.4 328 64 0 255 19.2 0 19.7 19.1 05/29/2005 13:50:00 3.1 1.3 6.1 0.4 3 1.5 6.1 0.4 2.7 1.4 6.1 0.4 42 33 58 255 19.1 0.1 20 18.8 05/29/2005 14:00:00 4.4 1 8 1.9 4.3 1 8 1.9 3.8 1 6.8 1.5 37 22 49 255 18.8 0.2 19.4 18.2 05/29/2005 14:10:00 3.2 1.3 6.5 0.4 3.1 1.4 6.5 0.4 2.7 1.1 6.1 0.4 43 21 24 255 19 0.3 19.4 18.5 05/29/2005 14:20:00 4 0.6 5.7 2.3 3.9 0.7 6.1 1.9 3.1 1 5.7 1.1 13 15 37 255 19.2 0.4 20 18.5 05/29/2005 14:30:00 3.7 1.4 6.5 0.4 3.6 1.4 6.1 0.4 3.1 1.1 5.7 0.7 15 21 334 255 20.1 0.3 20.8 19.4 05/29/2005 14:40:00 2.9 1 5.3 0.7 2.8 1 5.3 0.7 2.3 1 4.9 0.4 28 18 21 255 19.5 0 19.7 19.4 05/29/2005 14:50:00 3.6 1.1 6.5 0.7 3.5 1.1 6.8 0.4 2.9 1.2 6.8 0.7 60 33 94 255 19.6 0.2 20 19.4 05/29/2005 15:00:00 4.1 1.5 7.2 0.4 4 1.5 6.8 0.4 3.6 1.5 6.8 0.4 42 24 12 255 19 0 19.4 18.8 05/29/2005 15:10:00 5.1 1 8.4 1.9 5 1 7.6 1.9 4.2 1.3 7.2 1.1 29 22 6 255 19.6 0.3 20.5 19.1 05/29/2005 15:20:00 6 1.2 8.4 3 5.9 1.2 8.8 2.6 4.4 1.3 8 1.5 13 19 315 255 19.7 0.4 20.5 19.1 05/29/2005 15:30:00 6 1 8.4 3 5.9 1 8 2.3 4.7 1.3 7.2 1.1 17 19 31 255 19.3 0 19.4 18.8 05/29/2005 15:40:00 4.6 1.1 7.2 1.9 4.4 1.2 6.8 1.1 3.4 1.2 7.2 0.7 5 22 8 255 19 0.3 19.4 18.5 05/29/2005 15:50:00 4.5 1 8 1.9 4.3 1.1 8 1.9 3.1 1.1 6.5 0.7 0 20 353 255 19.3 0.1 19.7 18.8 05/29/2005 16:00:00 4.4 1 7.2 1.9 4.2 1 7.2 1.5 3.1 1.2 6.1 0.7 1 20 359 255 18.8 0.2 19.1 18.5 05/29/2005 16:10:00 3.6 0.8 5.7 0.7 3.5 0.8 5.7 0.4 2.8 1 5.7 0.4 10 16 343 255 18.5 0 18.8 18.2 05/29/2005 16:20:00 5.2 1.5 8.4 2.3 5.1 1.5 8.4 2.3 3.8 1.5 7.2 0.7 8 16 358 255 18.1 0.2 18.5 17.7 05/29/2005 16:30:00 6.9 1.7 11.8 1.9 6.8 1.8 11.8 1.1 5.1 1.8 10.3 1.5 15 18 31 255 18.4 0.2 19.1 18 05/29/2005 16:40:00 8.4 1.6 13 4.2 8.3 1.6 13.3 4.2 6.8 2 10.7 1.5 23 13 10 255 18.2 0.1 18.8 17.7 05/29/2005 16:50:00 8.7 1.7 12.2 3.4 8.6 1.8 12.6 3.4 6.7 2.2 11.8 2.3 18 17 20 255 17.8 0.2 18.5 17.4 05/29/2005 17:00:00 8.9 1.7 13 3.8 8.9 1.7 13 3.8 7.1 1.8 12.2 3.4 18 12 5 255 17.3 0.1 18 17.1 05/29/2005 17:10:00 7.3 1.6 11.8 3.4 7.2 1.7 11.5 3 5.7 1.8 9.9 1.9 13 15 23 255 17.5 0.2 18 17.1 05/29/2005 17:20:00 7.1 1.2 11.1 3.4 7.1 1.2 10.7 3.4 5.7 1.5 8.8 1.5 18 16 24 255 17.8 0 18.2 17.4 05/29/2005 17:30:00 5.8 1.9 11.5 1.5 5.7 2 11.1 1.5 4.3 1.7 9.5 1.1 16 19 30 255 17.8 0 18.2 17.7 05/29/2005 17:40:00 5.8 1.8 9.1 1.1 5.7 1.8 9.1 0.7 4.5 1.7 8.8 1.5 18 18 16 255 17.7 0.1 18.2 17.4 05/29/2005 17:50:00 6.2 1.1 8.8 3.4 6.2 1.1 8.8 3 4.6 1.3 7.6 1.1 15 16 13 255 17.4 0.1 18 17.1 05/29/2005 18:00:00 5.3 1.4 9.5 1.5 5.3 1.4 8.8 1.5 4 1.5 7.6 0.7 17 16 14 255 17.3 0 17.7 17.1 05/29/2005 18:10:00 6.3 1 8.8 3 6.2 1.1 8.8 3.4 4.8 1.4 8 1.9 22 17 13 255 17.3 0 17.7 17.1 05/29/2005 18:20:00 6.2 1 8.4 3 6.1 1 8.4 3 4.9 1.2 7.6 1.9 21 14 31 255 17 0.1 17.7 16.8 05/29/2005 18:30:00 5.4 1.7 8.8 0.4 5.3 1.8 8.4 0.4 4 1.7 7.6 0.4 9 20 27 255 16.6 0 17.1 16.6 05/29/2005 18:40:00 6.1 1.5 9.9 2.3 6.1 1.5 9.9 2.3 4.7 1.5 8.4 1.1 16 18 40 255 16.3 0.1 16.8 16.3 05/29/2005 18:50:00 5.8 0.9 8.4 3.4 5.8 0.9 8.4 3.8 5 1.1 8 1.9 29 16 25 255 16 0 16.3 16 05/29/2005 19:00:00 6.8 1.4 10.7 3 6.8 1.5 11.1 2.3 5.5 1.5 9.1 1.9 25 15 7 255 15.7 0 16 15.7 05/29/2005 19:10:00 7.1 1.7 11.1 2.3 7 1.7 11.5 2.6 5.7 1.9 9.9 0.7 26 15 34 255 15.2 0.1 15.7 15.2 05/29/2005 19:20:00 7.1 1.3 10.3 4.2 7.1 1.3 10.3 3.8 5.9 1.7 9.5 1.9 25 12 27 255 15 0 15.5 15.2 05/29/2005 19:30:00 6.2 1 8.4 3 6.1 1 8.4 3.4 4.8 1.2 7.6 1.9 20 12 16 255 15 0 15.2 14.9 05/29/2005 19:40:00 5.1 1 7.6 1.9 5.1 1 7.6 2.6 4.4 1.1 8 1.5 26 12 31 255 14.8 0 15.2 14.6 05/29/2005 19:50:00 4.9 1.3 7.6 1.9 4.9 1.3 7.6 1.5 3.9 1.4 7.6 0.7 16 13 23 255 14.7 0.1 15.2 14.6 05/29/2005 20:00:00 5.1 0.9 7.2 3 5 0.9 7.6 3 4.1 0.9 6.1 1.5 26 15 8 255 14.6 0 15.2 14.6 05/29/2005 20:10:00 6 1.1 8.8 3.8 5.9 1.1 8.4 3.4 4.7 1.3 8.8 1.9 19 12 7 255 14.6 0 15.2 14.4 05/29/2005 20:20:00 6.3 1.4 10.7 3.4 6.3 1.4 10.3 3 4.5 1.5 8.8 1.5 17 13 14 255 14.3 0 14.6 14.4 05/29/2005 20:30:00 6.4 1.5 9.5 2.3 6.4 1.5 9.5 2.3 5.3 1.6 8.8 0.7 18 11 31 255 14.2 0 14.6 14.1 05/29/2005 20:40:00 5.8 1.2 8.8 2.6 5.8 1.2 8.8 2.6 4.7 1.4 8.4 0.7 24 16 25 255 14.1 0.1 14.6 13.8 05/29/2005 20:50:00 6 1.2 9.1 2.6 5.9 1.2 9.1 3 4.7 1.2 8 1.9 22 13 20 255 14 0.1 14.6 13.8 05/29/2005 21:00:00 5.5 1.3 8.8 1.9 5.5 1.3 8.4 2.3 4.4 1.5 8.4 0.7 23 17 33 255 13.8 0 14.4 13.5 05/29/2005 21:10:00 5.4 1.7 9.1 1.9 5.4 1.7 9.1 2.3 4.4 1.7 8.4 1.1 22 13 11 255 13.5 0 13.8 13.3 05/29/2005 21:20:00 6.1 1.1 9.5 3.8 6.1 1.2 9.5 3 4.7 1.3 8.4 1.9 22 14 22 255 13.3 0 13.5 13 05/29/2005 21:30:00 5 1.2 7.6 2.3 4.9 1.2 8 2.3 3.9 1.3 7.2 1.5 19 13 31 255 13.1 0 13.5 12.7 05/29/2005 21:40:00 4.9 1.2 8 2.3 4.9 1.3 8 2.3 3.8 1.5 7.2 0.7 22 15 24 255 12.9 0.1 13.5 12.7 05/29/2005 21:50:00 6.1 1 8.8 4.2 6 1.1 9.1 3.8 5 1.1 8 2.3 29 12 19 255 12.8 0 13.3 12.7 05/29/2005 22:00:00 6.4 1 8.8 4.2 6.3 1 8.8 4.2 5 1.1 7.6 1.9 24 13 13 255 12.8 0 13.3 12.7 05/29/2005 22:10:00 4.7 1 7.6 2.6 4.7 1 7.6 2.6 3.5 1.1 6.5 1.1 20 14 23 255 12.5 0 13 12.2 05/29/2005 22:20:00 4.8 1 7.2 2.6 4.7 1 7.2 2.6 3.4 1 6.5 1.1 16 12 19 255 12.1 0 12.5 11.9 05/29/2005 22:30:00 4.4 1.1 7.2 1.9 4.3 1.1 7.2 1.9 3.4 1.1 7.2 1.1 25 15 54 255 11.9 0.1 12.5 11.7 05/29/2005 22:40:00 3.8 0.9 6.8 1.1 3.7 0.9 7.2 1.1 2.9 1 6.1 0.4 23 14 30 255 11.9 0.1 12.5 11.7 05/29/2005 22:50:00 3.2 1 6.1 0.4 3.2 1.1 6.1 0.4 2.4 1 6.5 0.4 18 17 358 255 11.3 0.1 11.9 11.1 05/29/2005 23:00:00 3.1 1 5.3 0.7 3.1 1 5.3 0.7 2.5 0.8 4.6 0.7 39 17 7 255 11.5 0 11.7 11.1 05/29/2005 23:10:00 3 0.9 5.7 1.1 2.9 1 5.7 0.4 2.4 0.9 4.6 0.7 52 20 46 255 11.7 0 12.2 11.4 05/29/2005 23:20:00 2.4 1 6.1 0.4 2.4 1.1 6.1 0.4 1.9 1 5.7 0.4 68 28 63 255 11.3 0 11.7 11.1 05/29/2005 23:30:00 2.5 0.8 4.6 0.7 2.4 0.9 4.6 0.4 1.7 1 3.8 0.4 76 21 64 255 10.7 0.2 11.1 10.3 05/29/2005 23:40:00 2.9 0.6 4.9 1.1 2.9 0.6 4.6 1.1 2.1 0.6 3.4 0.4 69 13 21 255 9.9 0.2 10.3 9.6 05/29/2005 23:50:00 3.8 0.7 6.1 1.9 3.7 0.8 6.1 1.9 2.9 0.7 4.6 1.5 59 13 60 255 9.6 0 10.1 9.6 05/30/2005 00:00:00 3.2 0.8 4.9 1.1 3.2 0.9 5.3 1.1 2.3 0.8 4.6 0.4 56 13 58 255 10.1 0 10.3 9.8 05/30/2005 00:10:00 2.9 0.5 4.6 0.7 2.8 0.6 4.6 1.1 2 0.7 3.8 0.4 62 17 66 255 9.9 0.2 10.3 9.6 05/30/2005 00:20:00 3.3 0.6 4.9 1.9 3.3 0.6 4.9 1.5 2.4 0.6 3.8 1.1 74 9 75 255 8.8 0.3 9.6 8.5 05/30/2005 00:30:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 0.4 1.4 0.5 2.6 0.4 64 12 90 255 7.8 0.3 8.5 7.3 05/30/2005 00:40:00 2.6 0.3 3.4 1.5 2.5 0.4 3.4 1.5 1.8 0.4 3 1.1 52 7 50 255 7 0.2 7.3 6.7 05/30/2005 00:50:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.1 1.4 0.5 2.6 0.4 56 7 64 255 6.7 0 7 6.2 05/30/2005 01:00:00 2.3 0.4 3.4 1.1 2.3 0.5 3.8 0.7 1.6 0.5 3.4 0.4 64 8 52 255 6.3 0 6.5 6.2 05/30/2005 01:10:00 2.2 0.4 3.4 1.1 2.2 0.4 3.4 1.1 1.4 0.5 2.6 0.4 50 11 57 255 6.1 0 6.5 6 05/30/2005 01:20:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 0.8 0.4 1.9 0.4 23 18 35 255 5.9 0.1 6.2 5.7 05/30/2005 01:30:00 1.7 0.5 3.4 0.4 1.5 0.6 3.4 0.4 0.8 0.5 2.3 0.4 1 15 6 255 5.7 0 5.7 5.7 05/30/2005 01:40:00 1.6 0.3 2.6 0.7 1.5 0.3 2.3 0.7 1 0.3 1.9 0.4 42 14 37 255 5.6 0 5.7 5.5 05/30/2005 01:50:00 1.8 0.6 3 0.7 1.7 0.8 3 0.4 1.3 0.5 2.3 0.4 69 12 74 255 5.1 0 5.5 5 05/30/2005 02:00:00 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 59 8 68 255 4.9 0 5 4.8 05/30/2005 02:10:00 1.3 0.3 2.3 0.7 1.1 0.4 2.3 0.4 0.9 0.5 1.9 0.4 69 17 110 255 4.8 0 5 4.8 05/30/2005 02:20:00 2.1 0.7 3.8 0.7 2 0.8 3.4 0.4 1.6 0.6 3.4 0.4 116 11 118 255 4.5 0 4.8 4.3 05/30/2005 02:30:00 1.8 0.7 3 0.4 1.7 0.8 3.4 0.4 0.8 0.7 2.6 0.4 102 8 101 255 4.1 0 4.3 3.8 05/30/2005 02:40:00 1.8 0.3 2.6 0.7 1.8 0.4 2.6 0.7 0.8 0.4 1.5 0.4 82 6 80 255 4 0 4 3.8 05/30/2005 02:50:00 2.1 0.4 3 1.1 2 0.5 3 1.1 1 0.5 2.3 0.4 104 11 103 255 4 0 4.3 3.8 05/30/2005 03:00:00 1.6 0.6 3.4 0.4 1.4 0.7 3 0.4 0.9 0.6 2.6 0.4 90 9 111 255 3.8 0.1 4 3.5 05/30/2005 03:10:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.4 0.6 0.3 1.5 0.4 73 11 79 255 3.6 0 3.8 3.5 05/30/2005 03:20:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 81 26 104 255 3.6 0 3.8 3.5 05/30/2005 03:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 115 21 108 255 3.5 0 3.8 3.3 05/30/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 255 255 3.3 0 3.5 3.3 05/30/2005 03:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 86 0 86 255 3.2 0 3.3 3.3 05/30/2005 04:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 1 0.4 1.9 0.4 111 19 127 255 3.2 0 3.3 3.3 05/30/2005 04:10:00 1.6 0.4 2.3 0.7 1.3 0.5 2.3 0.4 0.5 0.3 1.5 0.4 111 8 108 255 3.2 0 3.3 3.3 05/30/2005 04:20:00 2.1 0.4 3 1.5 2 0.4 3 1.1 1.1 0.4 2.3 0.4 105 4 103 255 3.3 0 3.5 3.3 05/30/2005 04:30:00 1.9 0.5 2.6 0.4 1.8 0.5 2.6 0.4 1.1 0.5 2.3 0.4 106 5 102 255 3.5 0 3.8 3.3 05/30/2005 04:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 137 17 113 255 3.9 0 4 3.8 05/30/2005 04:50:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.6 0.5 3 0.4 139 9 144 255 4.3 0.2 4.8 4 05/30/2005 05:00:00 1.3 0.5 2.3 0.4 1.1 0.5 2.6 0.4 1 0.4 2.3 0.4 129 13 132 255 5 0.1 5.2 4.8 05/30/2005 05:10:00 1.6 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.4 0.4 2.3 0.4 124 9 127 255 5.5 0.2 5.7 5 05/30/2005 05:20:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.1 0.4 115 9 133 255 5.9 0 6 5.7 05/30/2005 05:30:00 2.1 0.5 3 0.7 2 0.6 3.4 0.7 1.2 0.5 2.6 0.4 112 12 106 255 6.1 0 6.2 6 05/30/2005 05:40:00 1.1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.6 0.4 1.9 0.4 113 8 121 255 6.3 0 6.7 6.2 05/30/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 77 9 81 255 6.8 0 7 6.7 05/30/2005 06:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 114 23 143 255 7.6 0.3 8.3 7 05/30/2005 06:10:00 2.2 0.6 3.4 0.7 2.2 0.7 3.4 0.4 1.9 0.6 3.4 0.4 129 9 121 255 8.5 0.1 8.8 8.3 05/30/2005 06:20:00 2 0.4 3 0.7 1.9 0.4 3 0.4 1.7 0.4 3 0.7 131 8 127 255 8.9 0 9 8.8 05/30/2005 06:30:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.5 2.6 0.4 135 12 126 255 9.2 0.1 9.6 9 05/30/2005 06:40:00 1.1 0.6 2.6 0.4 0.9 0.6 3 0.4 0.9 0.6 2.3 0.4 123 17 126 255 10.1 0.2 10.6 9.6 05/30/2005 06:50:00 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 132 12 116 255 10.7 0 11.1 10.6 05/30/2005 07:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 130 16 146 255 11.8 0.3 12.5 11.1 05/30/2005 07:10:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.1 0.5 2.3 0.4 31 20 357 255 12.9 0.1 13.5 12.5 05/30/2005 07:20:00 1.5 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.4 0.5 2.6 0.4 16 21 7 255 14 0.3 14.9 13.3 05/30/2005 07:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 20 26 30 255 14.1 0.1 14.9 13.8 05/30/2005 07:40:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 27 24 4 255 13.9 0 14.6 13.5 05/30/2005 07:50:00 1.5 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 29 18 21 255 13.2 0.2 13.8 12.7 05/30/2005 08:00:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.3 0.6 3 0.4 28 23 22 255 12.9 0 13.3 12.7 05/30/2005 08:10:00 0.9 0.5 1.9 0.4 0.8 0.5 2.3 0.4 1 0.4 2.3 0.4 58 17 48 255 12.8 0 13.3 12.7 05/30/2005 08:20:00 0.6 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.7 0.4 1.9 0.4 70 13 42 255 13.5 0.6 15.2 12.7 05/30/2005 08:30:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 53 102 54 255 15 0.1 15.7 14.6 05/30/2005 08:40:00 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 1 0.6 3 0.4 122 56 143 255 15.2 0.2 16 15.2 05/30/2005 08:50:00 0.7 0.4 2.3 0.4 0.5 0.2 1.9 0.4 0.6 0.4 1.5 0.4 15 43 25 255 15 0 15.5 14.9 05/30/2005 09:00:00 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.5 2.6 0.4 37 28 123 255 15.5 0 15.7 15.5 05/30/2005 09:10:00 1.9 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.6 0.7 3 0.4 30 17 5 255 14.8 0.2 15.7 14.6 05/30/2005 09:20:00 2.3 1 5.3 0.4 2.2 1 5.7 0.4 1.6 0.8 4.2 0.4 359 28 13 255 15 0 15.5 14.6 05/30/2005 09:30:00 2.4 0.7 3.8 0.4 2.3 0.7 4.2 0.4 1.9 0.7 3.8 0.4 14 26 338 255 14.9 0 15.5 14.9 05/30/2005 09:40:00 3.3 0.7 5.3 2.3 3.3 0.7 4.9 1.9 2.6 0.8 4.6 0.4 25 17 22 255 14.6 0 15.2 14.4 05/30/2005 09:50:00 3.5 1.3 5.7 0.4 3.4 1.3 5.7 0.4 3.1 1.2 5.7 0.4 13 29 22 255 15.2 0.2 16 14.6 05/30/2005 10:00:00 3.6 1.1 6.1 1.5 3.5 1.1 6.1 1.1 2.7 1.1 5.7 0.4 4 26 6 255 16 0.3 16.8 15.7 05/30/2005 10:10:00 3.9 0.9 5.7 1.5 3.7 0.9 6.1 1.1 2.8 1 4.9 0.4 7 30 340 255 17.3 0.2 17.7 16.8 05/30/2005 10:20:00 4.6 1.6 8.8 1.5 4.5 1.7 8.4 0.7 3.3 1.6 7.2 0.4 7 19 10 255 16.8 0.3 17.4 16.3 05/30/2005 10:30:00 3.6 1.2 6.1 0.7 3.4 1.3 5.7 0.4 2.6 1.3 6.5 0.4 357 19 339 255 17.4 0.2 17.7 17.1 05/30/2005 10:40:00 4.5 1.2 6.8 1.1 4.4 1.2 6.8 0.7 3.3 1.2 6.8 0.4 3 21 358 255 16.8 0 17.1 16.8 05/30/2005 10:50:00 3.3 1.3 5.7 0.4 3.1 1.4 5.7 0.4 2.4 1.1 5.3 0.4 358 21 358 255 17.2 0.4 18.5 16.6 05/30/2005 11:00:00 3 1.1 5.7 0.7 2.9 1.1 5.7 0.4 2.7 1 6.1 0.4 27 32 40 255 18.2 0.4 19.4 17.7 05/30/2005 11:10:00 4.2 1 6.5 0.7 4 1.2 6.5 0.4 3.3 1.1 5.7 0.4 2 21 350 255 18 0 18.5 17.7 05/30/2005 11:20:00 3.5 1 6.1 0.7 3.2 1 5.3 0.4 2.9 1 5.7 0.4 341 32 340 255 18.2 0.2 19.1 18 05/30/2005 11:30:00 2.5 1.3 5.3 0.4 2.2 1.2 4.6 0.4 1.9 1.1 5.3 0.4 351 43 348 255 18 0.3 19.1 17.4 05/30/2005 11:40:00 3 1 6.1 0.7 2.8 1 5.7 0.4 2.6 0.9 4.6 0.4 35 36 4 255 17.6 0.3 18.2 17.1 05/30/2005 11:50:00 2.4 0.8 3.8 0.4 2.4 0.8 3.8 0.4 2 0.9 3.8 0.4 36 41 25 255 18 0.4 18.8 17.1 05/30/2005 12:00:00 2 1.1 5.3 0.4 2 1.1 4.9 0.4 2 1 4.2 0.4 88 45 40 255 18.7 0.1 19.4 18.2 05/30/2005 12:10:00 1.4 0.9 4.2 0.4 1.2 0.9 4.6 0.4 1.4 1 4.2 0.4 268 64 272 255 19.2 0.4 20.5 18.5 05/30/2005 12:20:00 1.8 1.5 6.5 0.4 1.6 1.4 6.5 0.4 1.6 1.2 6.8 0.4 48 72 342 255 20.2 0.2 20.8 19.7 05/30/2005 12:30:00 3 1.2 6.1 0.4 2.9 1.2 6.5 0.4 2.5 1.3 6.1 0.4 10 43 351 255 20.5 0 20.8 20.3 05/30/2005 12:40:00 3.2 1.8 8.4 0.4 3.1 1.9 8 0.4 2.5 1.5 6.8 0.4 349 41 12 255 20.5 0 20.8 20.3 05/30/2005 12:50:00 5.4 2.3 10.7 1.1 5.2 2.4 11.1 0.7 4.1 2 9.9 0.7 4 20 17 255 20.3 0 20.8 20 05/30/2005 13:00:00 7.4 1.5 11.1 3 7.3 1.5 11.1 2.6 5.9 1.7 10.7 1.5 16 17 25 255 20 0 20.5 19.7 05/30/2005 13:10:00 6.2 1.7 9.9 2.3 6.1 1.7 9.5 1.9 4.7 1.7 8.8 0.7 12 16 22 255 20.4 0 20.8 20 05/30/2005 13:20:00 7.8 1.5 11.5 3.4 7.7 1.5 11.8 3.8 6.2 1.6 10.7 1.5 19 13 9 255 20.3 0 20.5 20 05/30/2005 13:30:00 6.8 1.7 10.3 3 6.7 1.7 10.3 2.6 5.2 1.9 9.9 1.5 17 13 30 255 20.8 0.2 21.1 20.5 05/30/2005 13:40:00 5.6 1.5 9.1 2.3 5.5 1.5 9.1 1.9 4.3 1.5 8.8 0.7 6 21 7 255 20.8 0 21.1 20.5 05/30/2005 13:50:00 5.8 1.8 10.7 2.6 5.6 1.9 10.7 2.3 4.5 1.7 8.8 1.5 0 29 37 255 21 0 21.4 20.8 05/30/2005 14:00:00 6.5 1.3 9.5 2.3 6.5 1.4 9.9 1.9 4.7 1.4 8.4 1.5 7 13 351 255 21 0 21.4 20.8 05/30/2005 14:10:00 4.9 1.6 9.1 1.1 4.8 1.6 9.1 0.4 3.8 1.5 8 0.4 8 23 359 255 21.3 0 21.4 21.1 05/30/2005 14:20:00 7 1.9 11.5 3 6.9 2 11.5 2.3 5.1 2.2 9.9 0.7 6 17 20 255 21.2 0.1 21.7 20.8 05/30/2005 14:30:00 8.3 1.6 12.2 3.4 8.3 1.6 12.2 3.4 6.3 1.9 10.7 1.5 13 11 6 255 21 0.2 21.7 20.8 05/30/2005 14:40:00 8.5 1.4 11.8 4.9 8.5 1.4 11.8 4.9 6.4 1.7 11.1 2.6 15 13 23 255 21.4 0.1 22 21.1 05/30/2005 14:50:00 9.4 1.8 13.3 4.6 9.5 1.9 13.7 4.9 7.1 2.1 12.2 2.3 10 11 8 255 20.8 0.3 21.4 20 05/30/2005 15:00:00 6.6 1.5 10.7 2.6 6.6 1.5 11.1 2.3 5.1 1.5 9.1 1.5 21 21 0 255 20 0.3 21.1 19.4 05/30/2005 15:10:00 7 2.3 11.8 0.4 6.9 2.3 12.2 0.4 5.1 2.3 11.1 0.7 5 18 356 255 18.8 0.4 20 18 05/30/2005 15:20:00 7.3 1.9 13 3 7.3 2 13 2.3 5.8 1.9 11.5 1.1 17 14 16 255 18 0.2 18.5 17.7 05/30/2005 15:30:00 7.6 2.1 12.2 3 7.6 2.2 12.2 2.6 5.8 2.3 12.2 1.5 8 15 2 255 17.8 0 18.2 17.4 05/30/2005 15:40:00 7.7 2.2 11.8 2.3 7.6 2.3 11.8 1.5 5.7 2.2 10.3 1.1 14 15 15 255 18.2 0.2 19.1 17.7 05/30/2005 15:50:00 8.5 1.5 14.1 4.2 8.4 1.5 14.1 4.2 6.2 1.8 11.1 2.3 12 17 16 255 18.7 0.1 19.4 18.5 05/30/2005 16:00:00 7.6 2 12.2 2.6 7.5 2.1 12.6 2.6 5.5 2 11.8 1.5 9 19 28 255 19.7 0.2 20.3 19.1 05/30/2005 16:10:00 8.7 1.2 12.6 4.9 8.7 1.2 12.6 5.3 6.2 1.6 10.3 3 10 15 12 255 19.4 0 20 19.1 05/30/2005 16:20:00 8.4 1.5 11.8 3.4 8.4 1.5 11.8 3 6.4 1.9 11.1 2.3 10 17 350 255 19.6 0.1 20 19.4 05/30/2005 16:30:00 8.5 1.5 12.2 3.8 8.4 1.6 11.8 3.8 6.3 1.9 10.7 2.3 16 17 49 255 20 0 20.5 19.7 05/30/2005 16:40:00 7.5 1.7 12.6 3.4 7.5 1.7 12.2 3.4 6.1 1.9 11.8 1.1 18 15 19 255 19.7 0.1 20 19.4 05/30/2005 16:50:00 8 1.7 11.8 2.6 8 1.7 11.8 2.6 6.3 2.2 11.1 1.9 16 17 24 255 18.4 0.6 19.7 17.4 05/30/2005 17:00:00 8.2 1.7 13 4.2 8.2 1.7 13 3.8 6.7 1.8 12.6 2.6 21 13 12 255 17.6 0.2 18 17.1 05/30/2005 17:10:00 8.8 1.5 12.6 5.3 8.8 1.5 13 5.3 7.4 1.7 12.6 3.8 24 13 18 255 16.9 0.1 17.4 16.6 05/30/2005 17:20:00 7.6 1.5 12.2 3.4 7.5 1.5 12.2 2.6 5.8 1.9 11.8 2.3 18 15 38 255 16.5 0.1 16.8 16.3 05/30/2005 17:30:00 7.5 1.5 11.1 3.8 7.4 1.5 10.7 3.8 5.9 1.6 9.9 2.3 20 14 27 255 16.4 0 16.8 16.3 05/30/2005 17:40:00 6.7 1.8 11.1 1.9 6.6 1.8 11.1 2.3 5.1 1.8 9.9 1.5 19 15 25 255 16.2 0 16.6 16 05/30/2005 17:50:00 7.2 1.6 13 3.8 7.2 1.7 13 3.4 5.3 2 11.1 1.9 19 15 21 255 15.8 0.1 16.3 15.7 05/30/2005 18:00:00 7.4 1.3 9.9 3.8 7.4 1.2 9.9 4.2 6.2 1.6 9.9 1.1 22 14 10 255 15.6 0 16 15.7 05/30/2005 18:10:00 6.8 1.6 11.1 3 6.7 1.6 11.1 3.4 5.2 1.8 9.5 1.5 19 13 12 255 15.6 0 15.7 15.7 05/30/2005 18:20:00 7 1.4 10.7 3.8 7 1.4 10.7 3.8 5.4 1.7 9.5 1.9 16 13 29 255 15.2 0.1 15.7 15.2 05/30/2005 18:30:00 6.6 1.2 9.9 3.4 6.5 1.3 9.5 3.4 5.2 1.3 8.8 1.5 21 15 9 255 14.8 0 15.2 14.6 05/30/2005 18:40:00 7 1.1 9.9 3.8 7 1.2 9.9 3 5.7 1.5 9.1 2.3 22 13 33 255 14.6 0 14.9 14.6 05/30/2005 18:50:00 7.8 1.4 11.5 4.2 7.8 1.5 11.8 3.4 6.4 1.7 11.5 3.4 22 13 18 255 14.4 0 14.9 14.4 05/30/2005 19:00:00 8 1.6 12.2 3.8 7.9 1.7 12.6 3.8 6.3 1.7 11.5 2.6 21 13 31 255 14.1 0 14.4 13.8 05/30/2005 19:10:00 7.4 1.4 11.1 3 7.4 1.4 11.5 2.6 5.6 1.6 10.3 1.9 19 14 14 255 13.9 0 14.4 13.5 05/30/2005 19:20:00 7.6 1.5 12.2 4.2 7.6 1.5 11.8 4.2 5.7 1.5 11.1 2.6 20 14 15 255 13.8 0 14.4 13.5 05/30/2005 19:30:00 6.7 1.3 9.5 4.2 6.7 1.3 9.5 3.4 5.3 1.6 8.8 1.9 22 13 25 255 13.6 0 14.1 13.3 05/30/2005 19:40:00 6.9 1.2 10.7 4.2 6.8 1.2 10.7 3.8 5.3 1.2 9.1 2.3 21 13 35 255 13.7 0.1 14.1 13.5 05/30/2005 19:50:00 5.8 1.7 11.1 2.3 5.8 1.8 11.5 2.3 4.5 1.7 8.8 1.5 20 13 12 255 13.5 0.1 14.1 13.3 05/30/2005 20:00:00 5.9 1.3 9.9 2.6 5.8 1.4 9.5 2.3 4.2 1.5 8.4 1.1 12 13 17 255 13.2 0.1 13.8 13 05/30/2005 20:10:00 4.8 1.2 8.4 1.5 4.8 1.2 8 1.1 3.3 1.3 6.5 0.4 13 17 15 255 12.9 0.1 13.3 12.7 05/30/2005 20:20:00 4.8 1.3 8.8 1.5 4.7 1.4 9.1 1.1 3.5 1.3 8 0.7 15 16 23 255 12.8 0 13.3 12.7 05/30/2005 20:30:00 5.7 1.7 10.7 1.1 5.6 1.8 10.7 0.7 4.4 1.7 8 0.4 22 19 22 255 12.9 0.1 13.3 12.7 05/30/2005 20:40:00 4.3 1.2 7.6 1.5 4.2 1.2 7.2 1.1 3 1.2 6.5 0.7 8 17 10 255 12.9 0 13.3 12.7 05/30/2005 20:50:00 4.7 1.2 8 2.3 4.6 1.2 8.4 2.3 3.1 1.3 6.8 0.4 8 15 340 255 12.7 0 13 12.5 05/30/2005 21:00:00 5.9 1.2 9.1 2.6 5.8 1.2 9.1 2.6 4.4 1.5 8 1.5 16 12 12 255 12.7 0 13.3 12.5 05/30/2005 21:10:00 6 1 8 3.4 5.9 1 8 3 4.9 1.2 7.6 2.3 24 11 12 255 12.6 0.1 13.3 12.5 05/30/2005 21:20:00 5.2 0.9 8 2.6 5.1 0.9 7.2 2.6 3.9 1 7.2 1.5 19 14 350 255 12.3 0 12.7 12.2 05/30/2005 21:30:00 4.5 0.9 6.8 2.6 4.3 1 6.8 2.3 3.5 1 6.1 1.5 24 13 8 255 12.3 0 12.7 12.2 05/30/2005 21:40:00 4.6 0.6 6.5 2.6 4.5 0.6 6.5 2.6 3.6 0.8 6.1 1.9 30 14 68 255 12.2 0 12.5 12.2 05/30/2005 21:50:00 4.2 0.6 6.5 2.6 4.1 0.7 6.5 2.3 3.5 0.7 5.3 1.5 30 12 28 255 12.1 0 12.5 11.9 05/30/2005 22:00:00 5.5 1 8 2.6 5.4 1 8 2.3 4.3 1.1 6.8 1.1 24 13 27 255 12 0 12.2 11.9 05/30/2005 22:10:00 5.3 1 7.6 3 5.3 1 8 3 4.3 1.1 6.8 1.5 29 13 23 255 11.8 0 11.9 11.7 05/30/2005 22:20:00 4.2 0.9 6.8 1.1 4.1 0.9 6.8 1.5 3.1 1.1 6.1 0.7 26 13 43 255 11.7 0 11.9 11.7 05/30/2005 22:30:00 4.3 1 6.8 1.5 4.1 1.1 6.8 1.5 3.4 1.2 7.6 1.1 29 16 35 255 11.5 0 11.7 11.4 05/30/2005 22:40:00 3.3 0.8 5.3 0.7 3.1 1 5.3 0.4 2 0.8 4.9 0.4 23 19 32 255 11.2 0 11.4 11.1 05/30/2005 22:50:00 2.6 0.7 5.3 1.1 2.3 0.8 5.3 0.7 1.9 0.7 3.8 0.4 39 20 13 255 11 0 11.1 10.9 05/30/2005 23:00:00 1.9 0.5 3 0.7 1.6 0.6 3 0.4 1.5 0.6 3 0.4 66 19 62 255 10.7 0 11.1 10.6 05/30/2005 23:10:00 2.5 0.8 4.9 0.7 2.3 0.9 4.9 0.4 1.9 0.8 3.8 0.4 61 22 13 255 10.4 0 10.6 10.3 05/30/2005 23:20:00 3.6 1 6.1 0.4 3.5 1.1 5.7 0.4 2.9 1 5.7 0.4 36 17 21 255 10.5 0 10.6 10.3 05/30/2005 23:30:00 3.7 0.7 5.7 2.3 3.5 0.8 5.7 1.9 2.9 0.8 4.9 1.1 30 13 21 255 10.6 0 10.6 10.6 05/30/2005 23:40:00 4.8 0.8 6.5 2.6 4.6 0.8 6.5 2.3 3.8 0.7 5.7 1.9 38 10 9 255 10.7 0 11.1 10.6 05/30/2005 23:50:00 4.3 0.8 6.8 2.6 4.2 0.8 6.8 2.3 3.4 1 5.7 1.1 42 15 29 255 10.9 0 11.1 10.9 05/31/2005 00:00:00 4.5 0.7 6.1 3 4.4 0.7 6.1 1.9 3.7 0.7 5.7 1.9 33 12 52 255 10.9 0 11.1 10.9 05/31/2005 00:10:00 3.9 0.5 5.3 2.3 3.8 0.5 5.3 2.3 3.3 0.7 5.3 1.5 31 9 45 255 10.7 0 10.9 10.6 05/31/2005 00:20:00 3.9 0.6 4.9 2.3 3.8 0.6 4.9 2.3 3 0.7 4.9 1.5 24 12 18 255 10.5 0 10.6 10.3 05/31/2005 00:30:00 3.8 0.7 5.7 1.5 3.7 0.7 5.7 1.9 3.1 0.8 4.9 1.5 36 15 28 255 10.2 0 10.6 10.3 05/31/2005 00:40:00 3.3 0.6 5.3 1.5 3.1 0.7 4.9 1.1 2.4 0.6 3.8 0.7 62 14 31 255 9.9 0.1 10.3 9.6 05/31/2005 00:50:00 2.9 0.6 4.6 1.1 2.8 0.7 4.9 1.1 2.2 0.8 4.2 0.4 52 15 59 255 9.4 0 9.6 9 05/31/2005 01:00:00 1.1 0.8 3.4 0.4 0.9 0.7 3 0.4 0.7 0.5 2.3 0.4 35 22 51 255 8.5 0.3 9.3 8 05/31/2005 01:10:00 2.4 1 4.9 0.4 2.3 1 4.9 0.4 1.8 0.8 3.8 0.4 68 15 89 255 8.1 0 8.3 8 05/31/2005 01:20:00 3.3 0.8 5.7 1.1 3.2 0.8 5.3 0.7 2.2 0.9 4.9 0.4 72 17 25 255 8.2 0 8.5 8 05/31/2005 01:30:00 2.9 0.7 4.6 1.1 2.7 0.8 4.9 0.4 2.1 0.7 4.2 0.4 67 17 38 255 8.5 0 8.8 8.5 05/31/2005 01:40:00 3.5 0.8 5.3 1.9 3.5 0.8 5.7 1.5 2.7 0.8 4.9 0.7 73 15 58 255 8.5 0 8.8 8.5 05/31/2005 01:50:00 3.2 0.7 5.3 1.5 3.1 0.7 5.3 1.1 2.4 0.7 4.6 0.7 66 16 42 255 8.3 0 8.5 8.3 05/31/2005 02:00:00 3.1 0.6 4.6 1.9 3 0.6 4.6 1.5 2.3 0.6 4.2 1.1 68 13 67 255 8.1 0 8.5 8 05/31/2005 02:10:00 3.5 0.7 5.3 1.5 3.4 0.7 5.3 1.9 2.8 0.7 4.9 1.1 65 12 69 255 8.2 0.1 8.5 8 05/31/2005 02:20:00 3.6 0.8 5.7 1.9 3.6 0.8 5.7 1.9 2.7 0.8 4.6 0.7 63 12 77 255 8.4 0 8.5 8.5 05/31/2005 02:30:00 2.5 0.6 4.2 1.1 2.3 0.6 3.8 0.4 1.7 0.6 3.4 0.4 72 14 54 255 8.4 0 8.5 8 05/31/2005 02:40:00 2.8 0.6 4.6 0.7 2.6 0.6 4.6 0.7 2.1 0.7 3.8 0.4 62 11 44 255 8 0 8.3 7.8 05/31/2005 02:50:00 3.2 0.5 4.6 1.5 3.1 0.5 4.6 1.9 2.4 0.6 3.8 0.7 61 11 66 255 8 0 8.3 7.8 05/31/2005 03:00:00 3.6 0.7 5.3 1.5 3.5 0.8 5.3 1.1 2.8 0.6 4.6 1.5 65 13 49 255 8.3 0.2 8.5 8 05/31/2005 03:10:00 4.1 0.6 5.3 2.6 4 0.6 5.3 2.3 3.1 0.6 4.6 1.1 80 9 71 255 8.5 0 8.8 8.5 05/31/2005 03:20:00 4.2 1 6.5 0.7 4.1 1 6.5 0.7 3.2 1 5.3 0.7 72 16 87 255 8.9 0.1 9 8.8 05/31/2005 03:30:00 4 0.8 6.1 1.9 4 0.8 6.1 1.5 3.2 0.8 4.9 1.1 75 12 54 255 9 0 9.3 9 05/31/2005 03:40:00 3.9 0.9 6.5 1.5 3.8 0.9 6.5 1.5 3.1 0.9 6.1 1.1 58 14 44 255 9 0 9 9 05/31/2005 03:50:00 3.9 0.8 5.7 1.9 3.9 0.8 5.7 1.5 3.1 0.8 4.9 1.5 56 13 21 255 9.1 0 9.3 9 05/31/2005 04:00:00 4.2 1 6.8 2.3 4.2 1.1 7.2 1.5 3.3 1 6.8 1.5 57 15 53 255 9 0 9 9 05/31/2005 04:10:00 4.1 0.7 5.7 1.9 4 0.8 6.1 1.5 3.1 0.7 4.6 1.5 57 14 55 255 9 0 9 9 05/31/2005 04:20:00 3.5 0.7 5.7 1.9 3.5 0.7 5.7 1.9 2.7 0.6 4.6 0.7 63 14 62 255 8.7 0 9 8.5 05/31/2005 04:30:00 3.2 0.7 4.9 1.5 3.2 0.7 5.3 1.5 2.3 0.8 4.6 0.4 58 13 59 255 8.7 0 8.8 8.5 05/31/2005 04:40:00 3.4 0.8 4.9 1.5 3.3 0.8 4.9 0.7 2.5 0.7 4.2 0.7 65 15 66 255 8.6 0 8.8 8.5 05/31/2005 04:50:00 3.1 0.8 4.9 1.5 3 0.8 4.9 1.1 2.2 0.9 4.2 0.4 71 13 64 255 8.5 0 8.5 8.5 05/31/2005 05:00:00 2.9 0.7 4.6 1.5 2.7 0.7 4.6 1.5 2 0.6 3.4 0.4 70 16 66 255 8.4 0 8.5 8.5 05/31/2005 05:10:00 3 0.9 4.9 0.4 2.9 0.9 4.9 0.4 2.2 0.8 3.8 0.4 56 15 53 255 8.5 0 8.8 8.5 05/31/2005 05:20:00 3 0.7 5.3 1.5 2.9 0.7 5.3 0.7 2.2 0.6 4.2 0.4 55 14 46 255 8.7 0 8.8 8.5 05/31/2005 05:30:00 2.7 0.7 4.6 0.7 2.5 0.8 4.6 0.4 1.9 0.7 3.8 0.4 57 16 55 255 8.7 0 8.8 8.5 05/31/2005 05:40:00 2.3 0.7 3.8 0.7 2.2 0.7 3.8 0.4 1.6 0.7 3.4 0.4 57 15 50 255 8.6 0 8.8 8.5 05/31/2005 05:50:00 2.5 0.5 4.2 1.1 2.3 0.6 4.2 0.7 1.7 0.5 2.6 0.4 77 11 71 255 8.5 0 8.8 8.5 05/31/2005 06:00:00 2.8 0.4 4.2 1.5 2.7 0.5 4.2 1.5 1.8 0.6 3.4 0.4 79 9 68 255 8.7 0 9 8.5 05/31/2005 06:10:00 3 0.6 4.6 1.5 3 0.6 4.6 1.1 2.3 0.6 3.8 0.7 67 12 64 255 9.4 0.3 10.3 9 05/31/2005 06:20:00 2.9 0.5 4.2 1.5 2.9 0.6 4.6 1.1 2.4 0.7 4.2 0.4 68 12 74 255 10.5 0 10.6 10.3 05/31/2005 06:30:00 2.8 0.9 4.9 0.7 2.7 0.9 4.9 0.4 2.3 0.8 4.6 0.7 73 13 69 255 10.3 0 10.6 10.3 05/31/2005 06:40:00 2.8 0.9 5.3 0.7 2.7 1 5.3 0.4 2.1 1 4.6 0.4 71 17 81 255 10.6 0 10.9 10.6 05/31/2005 06:50:00 2.6 1 4.9 0.4 2.5 1 4.9 0.4 2.2 1 4.2 0.4 57 15 62 255 10.8 0 11.1 10.6 05/31/2005 07:00:00 3 0.7 4.6 1.5 2.9 0.7 4.9 1.5 2.5 0.8 4.2 0.7 47 17 28 255 11.1 0 11.4 10.9 05/31/2005 07:10:00 2.8 0.8 4.6 0.4 2.8 0.9 4.6 0.4 2.3 0.9 4.6 0.4 40 15 25 255 11.5 0 11.7 11.4 05/31/2005 07:20:00 2.5 0.6 4.2 0.7 2.3 0.7 4.2 0.7 2.2 0.7 4.9 0.7 43 16 36 255 11.7 0 11.9 11.7 05/31/2005 07:30:00 1.9 0.9 4.2 0.4 1.7 1 4.2 0.4 1.4 0.8 3.4 0.4 51 18 81 255 11.9 0 12.2 11.7 05/31/2005 07:40:00 2.3 0.6 4.2 0.7 2.2 0.7 3.8 0.4 2 0.8 3.8 0.4 31 17 47 255 13.3 0.5 14.6 12.2 05/31/2005 07:50:00 2.7 0.9 4.6 0.4 2.6 0.9 4.9 0.4 2.2 1.1 4.6 0.4 16 19 26 255 14.9 0.1 15.7 14.4 05/31/2005 08:00:00 2.1 0.8 4.2 0.4 1.9 1 4.2 0.4 1.9 0.8 3.8 0.4 357 21 353 255 15.2 0.1 16 15.2 05/31/2005 08:10:00 2.4 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.9 0.9 4.6 0.4 11 22 40 255 16 0 16.6 15.7 05/31/2005 08:20:00 2.4 1 5.3 0.4 2.3 1 5.3 0.4 2 0.9 3.8 0.4 14 19 15 255 15.2 0.1 15.7 15.2 05/31/2005 08:30:00 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 6 16 2 255 15.2 0 15.7 15.2 05/31/2005 08:40:00 1.7 0.7 3 0.4 1.5 0.7 3.4 0.4 1.4 0.7 3 0.4 2 15 11 255 15.9 0.1 16.3 15.5 05/31/2005 08:50:00 1 0.6 3 0.4 0.8 0.6 3 0.4 0.9 0.6 2.6 0.4 21 27 321 255 16.1 0 16.3 15.7 05/31/2005 09:00:00 1.7 0.8 3.4 0.4 1.6 0.8 3.8 0.4 1.7 0.7 3.4 0.4 29 35 40 255 15.4 0 15.7 15.2 05/31/2005 09:10:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 48 49 87 255 15.7 0.1 16.3 15.5 05/31/2005 09:20:00 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.6 0.7 3.4 0.4 41 22 12 255 16.3 0.1 16.8 16 05/31/2005 09:30:00 1.1 0.6 3 0.4 0.9 0.6 3 0.4 1.2 0.5 2.6 0.4 62 61 145 255 16 0 16.8 15.7 05/31/2005 09:40:00 0.8 0.7 3 0.4 0.7 0.6 3 0.4 0.8 0.6 2.6 0.4 73 51 62 255 16.3 0.1 16.8 16.3 05/31/2005 09:50:00 2.2 0.9 4.9 0.4 2 0.9 4.9 0.4 1.9 0.8 4.6 0.4 5 47 359 255 16.4 0.3 17.1 16 05/31/2005 10:00:00 1.5 1 3.8 0.4 1.3 1 4.2 0.4 1.4 1 3.4 0.4 297 76 313 255 16.7 0.2 17.1 16.3 05/31/2005 10:10:00 1.7 0.9 3.8 0.4 1.4 0.9 3.8 0.4 1.5 0.9 3.8 0.4 0 43 347 255 17.3 0.2 18 16.8 05/31/2005 10:20:00 1.8 1 4.6 0.4 1.6 1 4.2 0.4 1.6 1 4.9 0.4 311 43 302 255 17.8 0 18.2 17.4 05/31/2005 10:30:00 1.8 1 4.6 0.4 1.6 1 4.2 0.4 1.6 0.9 4.6 0.4 251 39 250 255 17.8 0 18.5 17.7 05/31/2005 10:40:00 1.7 1 4.9 0.4 1.5 1 4.6 0.4 1.3 0.9 3.8 0.4 266 53 317 255 18 0.1 18.5 17.7 05/31/2005 10:50:00 1.2 0.7 3 0.4 1 0.6 3 0.4 1.3 0.5 2.6 0.4 259 64 247 255 17.3 0.4 18.2 16.6 05/31/2005 11:00:00 1.6 1 4.6 0.4 1.3 1 4.6 0.4 1.2 0.8 3.8 0.4 237 69 310 255 17.3 0.4 18.2 16.8 05/31/2005 11:10:00 2 0.8 3.8 0.4 1.8 0.9 3.4 0.4 1.7 0.9 3.4 0.4 294 38 293 255 18 0.2 18.8 17.4 05/31/2005 11:20:00 1.6 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.4 0.8 3.8 0.4 286 51 267 255 17.6 0 18 17.1 05/31/2005 11:30:00 1.3 0.9 4.2 0.4 1.1 0.9 4.2 0.4 1.2 0.8 3.8 0.4 359 64 305 255 18.2 0.2 18.8 17.7 05/31/2005 11:40:00 2.4 1 5.3 0.4 2.1 1 5.3 0.4 1.8 1 4.2 0.4 339 39 305 255 18.5 0.1 18.8 18.2 05/31/2005 11:50:00 2.5 1.2 5.3 0.4 2.2 1.3 5.3 0.4 2.1 1.2 4.9 0.4 296 24 270 255 18.6 0.1 19.4 18.2 05/31/2005 12:00:00 2.5 1 4.9 0.4 2.2 1.1 4.9 0.4 2 1.1 4.6 0.4 294 45 260 255 19.7 0.3 20.3 18.8 05/31/2005 12:10:00 2.8 1.2 6.1 0.4 2.6 1.3 5.7 0.4 2.6 1.2 6.5 0.4 237 45 317 255 19.5 0.4 20.5 18.8 05/31/2005 12:20:00 2.8 1.2 5.7 0.4 2.5 1.3 5.7 0.4 2.1 1.2 5.7 0.4 310 35 301 255 19.7 0.3 20.5 19.1 05/31/2005 12:30:00 3.6 1.2 7.6 1.1 3.3 1.2 7.2 0.4 3 1.1 5.7 0.7 324 27 315 255 21.2 0.3 21.7 20.5 05/31/2005 12:40:00 3.3 1.1 5.3 0.4 3.2 1.2 5.3 0.4 2.9 1.1 6.1 0.4 307 18 313 255 18.6 0.7 20.5 17.7 05/31/2005 12:50:00 3.3 1.2 6.1 0.4 3 1.3 6.1 0.4 2.5 1.2 6.5 0.4 319 29 298 255 17.8 0 17.7 17.7 05/31/2005 13:00:00 3.3 1.1 5.7 0.4 3 1.2 5.7 0.4 2.6 1.2 5.7 0.4 328 22 311 255 17.7 0 18 17.4 05/31/2005 13:10:00 2.7 0.8 4.9 0.7 2.4 1 4.6 0.4 2.1 0.9 4.6 0.4 319 22 316 255 18 0 18.2 17.7 05/31/2005 13:20:00 2.3 1.1 4.9 0.4 2 1.2 4.9 0.4 1.7 1 4.6 0.4 294 30 301 255 18.1 0 18.5 17.7 05/31/2005 13:30:00 3.1 1 6.1 0.7 3 1 6.1 0.7 2.8 0.9 6.1 0.4 289 24 282 255 18.1 0 18.8 18 05/31/2005 13:40:00 3.9 1.3 6.8 1.1 3.7 1.4 6.8 0.7 3.5 1.2 7.2 1.1 291 17 301 255 19.1 0.3 19.4 18.2 05/31/2005 13:50:00 3.6 1 5.7 1.1 3.5 1.1 5.3 0.4 3.1 1.1 6.1 0.7 295 17 280 255 18.4 0.2 19.4 18 05/31/2005 14:00:00 3.3 1.2 6.1 0.4 3.2 1.2 6.1 0.4 2.9 1.2 5.7 0.4 262 43 291 255 18.5 0.1 19.1 18 05/31/2005 14:10:00 3 1.5 6.5 0.4 2.8 1.5 6.5 0.4 2.5 1.3 6.1 0.4 280 69 297 255 19 0.1 19.4 18.5 05/31/2005 14:20:00 3 1.2 6.1 0.4 2.8 1.3 6.1 0.4 2.3 1.3 6.1 0.4 306 28 290 255 19.5 0.1 20 19.1 05/31/2005 14:30:00 3.3 0.9 4.9 0.7 3.2 1 4.9 0.4 2.8 1 4.6 0.4 293 17 305 255 18.5 0.2 19.1 18 05/31/2005 14:40:00 2.7 1 4.9 0.4 2.4 1 4.6 0.4 1.9 1.1 4.6 0.4 317 32 311 255 18.6 0.2 19.1 18 05/31/2005 14:50:00 2.2 1.5 5.7 0.4 2 1.5 5.7 0.4 1.8 1.3 5.7 0.4 281 43 295 255 19 0.1 19.4 18.5 05/31/2005 15:00:00 3 1 6.5 0.4 2.8 1.2 5.7 0.4 2.5 1.1 6.1 0.4 278 24 299 255 19.2 0.2 19.7 18.8 05/31/2005 15:10:00 3.3 1.4 6.1 0.4 3.1 1.4 6.1 0.4 2.6 1.5 6.1 0.4 288 35 260 255 19.6 0.1 20 19.1 05/31/2005 15:20:00 4.3 1.3 6.8 0.4 4.2 1.3 7.2 0.7 3.7 1.4 6.8 0.4 287 29 286 255 19.4 0 20 19.1 05/31/2005 15:30:00 2.8 1.2 5.7 0.4 2.6 1.2 5.3 0.4 2.2 1.2 5.7 0.4 258 32 268 255 19.4 0.4 20.5 18.8 05/31/2005 15:40:00 3.4 1.2 5.7 0.4 3.3 1.3 6.1 0.4 2.8 1.1 5.7 0.4 282 20 276 255 18.9 0.7 20.5 18 05/31/2005 15:50:00 2.7 0.8 4.9 0.4 2.4 1 4.6 0.4 2.1 0.9 4.2 0.4 294 22 261 255 18.5 0 18.8 18.2 05/31/2005 16:00:00 4 1.1 6.5 0.7 3.5 1.1 6.1 0.7 3.1 1.1 5.7 0.7 336 24 323 255 18.4 0.3 19.1 18 05/31/2005 16:10:00 2.9 1.1 4.9 0.4 2.6 1.2 4.9 0.4 1.9 1 3.8 0.4 335 27 359 255 17.9 0 18.2 17.7 05/31/2005 16:20:00 3.1 1.1 5.7 0.4 2.8 1.2 6.1 0.4 2.2 1.2 4.9 0.4 356 19 345 255 18 0.2 18.5 17.7 05/31/2005 16:30:00 3.2 0.6 4.6 0.4 3 0.7 4.6 0.4 2 0.8 4.2 0.4 9 17 26 255 18 0 18.2 17.7 05/31/2005 16:40:00 2.2 1 4.6 0.4 1.8 1.1 4.6 0.4 1.5 1 4.2 0.4 326 22 294 255 17.6 0.2 18 17.1 05/31/2005 16:50:00 2.1 0.8 3.8 0.4 1.7 0.9 3.8 0.4 1.3 0.7 3.8 0.4 348 21 3 255 17.3 0.1 18 17.1 05/31/2005 17:00:00 2.4 0.8 4.2 0.7 2 0.9 4.6 0.4 1.6 0.8 3.4 0.4 337 26 334 255 17.3 0.1 18 17.1 05/31/2005 17:10:00 2.2 0.6 3.8 0.7 1.9 0.7 3.8 0.4 1.6 0.6 3 0.4 325 24 297 255 16.8 0.1 17.4 16.8 05/31/2005 17:20:00 2.7 1.2 5.3 0.4 2.5 1.3 6.1 0.4 2.1 1.1 5.7 0.4 297 41 312 255 16.8 0 16.8 16.6 05/31/2005 17:30:00 3.7 1.7 8 0.4 3.6 1.8 7.6 0.4 3 1.6 6.5 0.4 272 26 270 255 16.3 0.1 16.6 16 05/31/2005 17:40:00 4.7 1.3 8.4 1.1 4.6 1.3 8.4 1.1 3.5 1.2 7.6 0.7 287 24 256 255 15.6 0 16.3 15.5 05/31/2005 17:50:00 4.5 1.5 8.4 1.1 4.4 1.5 8 0.4 3.6 1.5 8.4 0.7 295 22 291 255 15.2 0.1 15.7 15.2 05/31/2005 18:00:00 4.5 1.1 7.2 1.9 4.3 1.2 7.6 1.5 3.4 1.2 6.8 0.4 310 18 301 255 14.4 0.4 15.2 13.5 05/31/2005 18:10:00 3.5 0.8 5.3 1.5 3.4 0.8 5.3 1.1 2.4 0.9 4.6 0.4 284 16 299 255 12.9 0.2 13.5 12.5 05/31/2005 18:20:00 2.6 0.9 5.3 0.4 2.5 1 4.6 0.4 1.8 0.9 5.3 0.4 269 21 267 255 12.4 0 12.7 12.2 05/31/2005 18:30:00 2.8 1 6.1 0.7 2.7 1.1 6.1 0.4 2 1 4.6 0.4 263 19 260 255 12.4 0 12.7 12.2 05/31/2005 18:40:00 3 1.6 7.2 0.4 2.8 1.7 7.2 0.4 2.1 1.4 7.6 0.4 257 26 256 255 12.7 0 13 12.5 05/31/2005 18:50:00 2.7 1.2 5.7 0.4 2.5 1.2 5.7 0.4 2 1.2 5.3 0.4 267 35 258 255 12.7 0 13 12.5 05/31/2005 19:00:00 3.7 1.3 6.5 0.4 3.5 1.4 6.8 0.4 2.9 1.1 6.5 0.7 262 23 286 255 12.9 0.1 13.3 12.5 05/31/2005 19:10:00 2.9 1.1 6.1 0.7 2.7 1.2 5.7 0.4 2.2 0.8 4.6 0.4 270 21 255 255 13 0.1 13.3 12.7 05/31/2005 19:20:00 3.1 1.3 6.8 0.4 3 1.5 6.5 0.4 2.3 1.1 5.7 0.4 264 27 273 255 12.9 0 13.3 12.7 05/31/2005 19:30:00 2.7 1.1 6.1 0.4 2.5 1.2 6.5 0.4 1.8 1 5.3 0.4 262 21 266 255 12.7 0 13.3 12.7 05/31/2005 19:40:00 1.6 1 5.3 0.4 1.3 1 4.9 0.4 1.1 0.7 3.4 0.4 267 47 312 255 12.7 0 13.3 12.5 05/31/2005 19:50:00 1.9 1 4.9 0.4 1.7 1 4.6 0.4 1.3 0.9 4.2 0.4 251 26 287 255 12.7 0 13 12.5 05/31/2005 20:00:00 0.9 0.7 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.6 0.4 279 30 235 255 12.7 0 13 12.7 05/31/2005 20:10:00 2.1 1 4.6 0.4 2 1.1 4.9 0.4 1.4 0.9 4.6 0.4 250 30 263 255 12.7 0 13 12.5 05/31/2005 20:20:00 2.7 1 5.7 0.7 2.6 1 5.3 0.4 1.8 1.1 5.7 0.4 237 22 251 255 12.2 0 12.7 11.9 05/31/2005 20:30:00 3 1.1 7.2 0.7 2.9 1.2 6.5 0.4 2.3 1 6.1 0.4 231 22 241 255 11.8 0 12.2 11.7 05/31/2005 20:40:00 2.5 1.1 4.9 0.4 2.5 1.2 4.9 0.4 1.9 0.9 4.2 0.4 223 17 212 255 11.5 0 11.9 11.4 05/31/2005 20:50:00 1.9 0.8 3.8 0.4 1.8 0.9 4.2 0.4 1.3 0.8 3.8 0.4 229 18 212 255 11.3 0 11.7 11.1 05/31/2005 21:00:00 2.7 1 5.3 0.4 2.6 1 5.3 0.4 1.8 1 4.9 0.4 233 22 246 255 11.1 0 11.7 11.1 05/31/2005 21:10:00 2.7 1.2 6.1 0.4 2.5 1.3 5.7 0.4 1.7 1 5.3 0.4 242 23 257 255 11.1 0 11.1 10.9 05/31/2005 21:20:00 2.3 1.2 6.1 0.4 2.1 1.3 6.5 0.4 1.7 1.1 6.1 0.4 252 15 268 255 10.9 0 11.1 10.9 05/31/2005 21:30:00 2 1 4.9 0.4 1.7 1 4.9 0.4 1.4 0.9 4.2 0.4 244 18 255 255 10.8 0 10.9 10.9 05/31/2005 21:40:00 2.2 0.8 4.6 0.4 2 0.9 4.6 0.4 1.5 0.7 4.2 0.4 244 24 244 255 10.7 0 10.9 10.6 05/31/2005 21:50:00 1.7 1 4.6 0.4 1.6 1 4.2 0.4 1.1 0.8 3.4 0.4 238 18 287 255 10.5 0 10.6 10.6 05/31/2005 22:00:00 1.8 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.2 0.7 3 0.4 240 13 255 255 10.4 0 10.6 10.3 05/31/2005 22:10:00 1.7 0.8 3.4 0.4 1.6 0.9 3.8 0.4 1.1 0.7 3.4 0.4 257 15 235 255 10.2 0 10.3 10.3 05/31/2005 22:20:00 1 0.7 3 0.4 0.9 0.7 3 0.4 0.7 0.6 2.6 0.4 244 18 257 255 10.2 0 10.3 10.3 05/31/2005 22:30:00 0.7 0.6 3 0.4 0.6 0.6 2.6 0.4 0.5 0.4 1.9 0.4 212 24 204 255 10.2 0 10.3 10.3 05/31/2005 22:40:00 1.3 0.8 4.2 0.4 1.1 0.8 3.8 0.4 0.7 0.5 2.3 0.4 216 14 232 255 10.2 0 10.3 10.1 05/31/2005 22:50:00 1.5 0.6 3 0.4 1.4 0.7 3 0.4 0.9 0.6 3 0.4 216 14 215 255 10 0 10.1 9.8 05/31/2005 23:00:00 1.8 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.2 0.5 2.6 0.4 221 16 226 255 9.8 0 10.1 9.8 05/31/2005 23:10:00 1.1 0.7 2.6 0.4 1 0.7 2.6 0.4 0.7 0.5 1.9 0.4 219 12 209 255 9.7 0 9.8 9.6 05/31/2005 23:20:00 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.9 0.4 240 11 257 255 9.6 0 9.6 9.6 05/31/2005 23:30:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 243 13 288 255 9.6 0 9.6 9.6 05/31/2005 23:40:00 0.8 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 252 11 249 255 9.5 0 9.6 9.3 05/31/2005 23:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 258 5 252 255 9.4 0 9.6 9.3 06/01/2005 00:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 247 7 251 255 9.4 0 9.6 9.3 06/01/2005 00:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 260 11 256 255 9.2 0 9.3 9 06/01/2005 00:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 243 0 244 255 9 0 9.3 9 06/01/2005 00:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 243 0 244 255 8.9 0 9 8.8 06/01/2005 00:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 0 244 255 8.7 0 8.8 8.5 06/01/2005 00:50:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 245 0 245 255 8.5 0 8.8 8.5 06/01/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.5 0 8.5 8.5 06/01/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.5 0 8.5 8.5 06/01/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.5 0 8.5 8.5 06/01/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.5 0 8.5 8.5 06/01/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.5 0 8.5 8.5 06/01/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.3 06/01/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 0 255 255 8.4 0 8.5 8.5 06/01/2005 03:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 3 245 255 8.4 0 8.5 8.5 06/01/2005 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 227 255 8.4 0 8.5 8.3 06/01/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 255 255 8.3 0 8.5 8.3 06/01/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 255 255 8.3 0 8.5 8.3 06/01/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 255 255 8.3 0 8.5 8.3 06/01/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 255 255 8.3 0 8.5 8.3 06/01/2005 04:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 47 334 255 8.4 0 8.5 8.3 06/01/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.4 0 8.5 8.5 06/01/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.4 0 8.5 8.5 06/01/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.5 0 8.5 8.5 06/01/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.5 0 8.8 8.5 06/01/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.7 0 8.8 8.5 06/01/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.7 0 8.8 8.8 06/01/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 8.9 0 9 8.8 06/01/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 9 0 9 8.8 06/01/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 9.3 0 9.6 9 06/01/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 255 255 9.8 0 10.1 9.6 06/01/2005 06:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 287 13 296 255 10.2 0 10.3 10.1 06/01/2005 06:10:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 350 16 353 255 10.2 0 10.3 10.1 06/01/2005 06:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 349 14 0 255 10.3 0 10.6 10.3 06/01/2005 06:30:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 338 4 334 255 10.3 0 10.6 10.3 06/01/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 335 0 255 255 10.4 0 10.6 10.3 06/01/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 344 12 1 255 10.7 0.1 11.1 10.6 06/01/2005 07:00:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 5 14 0 255 11.3 0 11.4 11.1 06/01/2005 07:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 350 22 358 255 11.4 0 11.7 11.4 06/01/2005 07:20:00 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.7 0.5 2.3 0.4 326 26 284 255 11.5 0 11.7 11.4 06/01/2005 07:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 319 12 3 255 11.2 0 11.7 11.1 06/01/2005 07:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 276 29 308 255 11.8 0.5 13.3 11.1 06/01/2005 07:50:00 1.1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 1.2 0.6 2.6 0.4 254 26 262 255 13.3 0 13.8 13 06/01/2005 08:00:00 1.2 0.8 3.4 0.4 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 302 24 339 255 12.9 0.3 13.5 12.2 06/01/2005 08:10:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.7 0.4 1.9 0.4 274 56 188 255 12.1 0.2 12.7 11.7 06/01/2005 08:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 177 20 181 255 11.7 0 12.2 11.7 06/01/2005 08:30:00 0.7 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.7 0.5 2.3 0.4 124 53 124 255 11.9 0.2 12.5 11.7 06/01/2005 08:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 140 19 148 255 11.9 0.4 13 11.7 06/01/2005 08:50:00 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 69 86 136 255 14 0.6 15.2 12.7 06/01/2005 09:00:00 1.3 0.6 2.6 0.4 1.2 0.7 3 0.4 1.1 0.6 2.6 0.4 300 47 335 255 14.9 0.4 15.7 13.8 06/01/2005 09:10:00 2.2 0.6 3.8 0.4 2.2 0.6 3.4 0.4 2.1 0.7 3.4 0.4 252 21 237 255 14.6 0.6 15.7 13.8 06/01/2005 09:20:00 2.7 0.9 4.9 0.4 2.6 1 4.9 0.4 2.1 1 4.9 0.4 242 24 253 255 14.7 0.6 16 13.5 06/01/2005 09:30:00 1.6 0.7 3 0.4 1.5 0.7 3 0.4 1.5 0.8 3 0.4 206 20 200 255 12.9 0.3 13.5 12.2 06/01/2005 09:40:00 1.1 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.5 2.6 0.4 178 22 196 255 12.4 0.1 13 12.2 06/01/2005 09:50:00 1.6 0.8 3 0.4 1.4 0.8 3 0.4 1.8 0.7 3 0.4 160 16 144 255 11.9 0.2 12.7 11.7 06/01/2005 10:00:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 169 12 152 255 11.9 0.1 12.5 11.7 06/01/2005 10:10:00 0.9 0.5 1.9 0.4 0.8 0.5 2.6 0.4 1.2 0.5 2.6 0.4 178 22 167 255 12.5 0.2 13 12.2 06/01/2005 10:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 79 43 144 255 12.8 0 13.3 12.7 06/01/2005 10:30:00 1.3 0.7 2.6 0.4 1 0.7 2.6 0.4 1.2 0.7 3 0.4 323 41 283 255 13.1 0.1 13.5 12.7 06/01/2005 10:40:00 2.9 0.8 4.9 0.7 2.8 0.9 4.6 0.4 2.4 0.8 4.6 0.7 289 21 311 255 13.4 0 13.8 13.3 06/01/2005 10:50:00 2.1 0.7 3.8 0.4 2 0.8 3.8 0.4 1.8 0.8 3.4 0.4 247 28 261 255 13.5 0.1 13.8 13.3 06/01/2005 11:00:00 2.4 1 4.2 0.4 2.3 1 4.2 0.4 2.5 0.9 4.2 0.7 185 29 219 255 14 0.1 14.6 13.8 06/01/2005 11:10:00 1 0.5 2.6 0.4 1 0.6 2.6 0.4 1.4 0.6 3 0.4 182 33 226 255 14.6 0 15.2 14.4 06/01/2005 11:20:00 1.6 0.6 3 0.4 1.7 0.7 3.4 0.4 1.7 0.7 3.4 0.4 178 26 186 255 14.3 0.2 15.2 13.5 06/01/2005 11:30:00 1.2 0.7 3 0.4 1.2 0.8 3 0.4 1.4 0.7 3 0.4 198 29 244 255 13.8 0 14.4 13.5 06/01/2005 11:40:00 1.5 1 3 0.4 1.3 1 3.4 0.4 1.4 0.9 3 0.4 235 27 248 255 14 0.1 14.6 13.8 06/01/2005 11:50:00 1.4 0.6 3 0.4 1.4 0.7 3 0.4 1.5 0.7 3.4 0.4 180 23 187 255 14.1 0.1 14.6 13.8 06/01/2005 12:00:00 1 0.6 3 0.4 0.9 0.6 3 0.4 1.3 0.7 4.2 0.4 151 21 199 255 14.4 0 14.9 14.1 06/01/2005 12:10:00 1.1 0.7 3 0.4 1 0.6 2.6 0.4 1 0.6 3 0.4 325 66 280 255 14.2 0 14.6 13.8 06/01/2005 12:20:00 2.3 1 4.6 0.7 2 1.1 4.2 0.4 1.7 1 4.2 0.4 327 33 10 255 14.6 0.3 15.5 14.1 06/01/2005 12:30:00 2.7 0.9 4.9 0.7 2.5 0.9 4.6 0.7 2.2 0.8 3.8 0.4 26 22 47 255 16.3 0.4 17.1 15.2 06/01/2005 12:40:00 1.7 0.6 3 0.4 1.6 0.7 3 0.4 1.7 0.7 3 0.4 27 41 45 255 16.9 0.2 17.4 16.3 06/01/2005 12:50:00 1.9 0.7 3.4 0.4 1.7 0.7 3.8 0.4 1.7 0.7 3.4 0.4 47 21 15 255 16.1 0.1 16.6 15.7 06/01/2005 13:00:00 1.4 0.7 3.4 0.4 1.2 0.7 3.4 0.4 1.2 0.7 3.4 0.4 35 22 40 255 15.7 0.2 16.3 15.2 06/01/2005 13:10:00 1.5 1 3.8 0.4 1.4 1.1 4.2 0.4 1.4 1 3.8 0.4 103 86 174 255 14.9 0.1 15.5 14.4 06/01/2005 13:20:00 1.7 0.9 3.4 0.4 1.7 1 3.4 0.4 1.7 0.8 3.8 0.4 179 22 196 255 14.1 0 14.4 13.8 06/01/2005 13:30:00 0.5 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.6 0.4 2.3 0.4 215 41 169 255 14.2 0 14.6 13.8 06/01/2005 13:40:00 0.7 0.6 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.4 1.9 0.4 272 38 328 255 14.3 0 14.6 13.8 06/01/2005 13:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 346 16 347 255 13.7 0 14.4 13.3 06/01/2005 14:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 67 98 159 255 12.8 0.3 13.8 12.2 06/01/2005 14:10:00 1.3 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.5 0.9 3.4 0.4 145 13 146 255 12 0.3 12.7 11.7 06/01/2005 14:20:00 1.1 0.7 3.8 0.4 0.9 0.6 3.4 0.4 1 0.6 3 0.4 83 61 38 255 11.3 0.4 12.2 10.6 06/01/2005 14:30:00 1.7 1.3 4.6 0.4 1.5 1.3 4.2 0.4 1.3 1 3.8 0.4 359 79 45 255 10.5 0.2 11.1 10.3 06/01/2005 14:40:00 3.5 1.4 6.5 0.7 3.4 1.5 6.1 0.4 2.4 1.3 5.7 0.4 287 22 313 255 11.9 1.3 14.6 10.3 06/01/2005 14:50:00 3.8 1.5 7.2 0.7 3.6 1.5 7.2 0.4 2.8 1.4 7.2 0.4 276 32 259 255 14.6 0.1 14.9 14.1 06/01/2005 15:00:00 3.5 1.6 8 0.4 3.5 1.7 7.6 0.4 2.6 1.4 8 0.4 249 24 252 255 13.7 0.3 14.6 13.3 06/01/2005 15:10:00 3.9 1.3 7.6 0.4 3.8 1.3 7.2 0.7 3.4 1.2 7.6 0.7 214 36 189 255 13.3 0.1 14.1 13 06/01/2005 15:20:00 3.5 1 6.1 0.7 3.6 1 5.7 0.7 2.8 1.1 5.7 0.4 198 28 201 255 13.7 0.2 14.6 13 06/01/2005 15:30:00 3.1 1.1 7.6 0.4 3.3 1.2 7.2 1.1 3.1 1.3 7.6 0.7 184 23 194 255 13.5 0 14.4 13.3 06/01/2005 15:40:00 3.6 1.1 6.8 1.1 3.7 1.2 6.8 1.5 2.9 1.1 6.5 0.4 191 26 181 255 13 0.2 13.8 12.7 06/01/2005 15:50:00 1.8 1.1 4.9 0.4 1.8 1.2 4.9 0.4 1.6 1 4.6 0.4 219 49 202 255 12.9 0.1 13.3 12.7 06/01/2005 16:00:00 2.6 1.2 5.7 0.4 2.6 1.2 5.7 0.4 2.5 1.1 5.3 0.4 169 28 133 255 13.1 0 13.5 12.7 06/01/2005 16:10:00 1.9 0.9 4.2 0.4 1.8 1 4.2 0.4 1.8 0.9 4.2 0.4 171 29 172 255 13.6 0.1 14.1 13.3 06/01/2005 16:20:00 1.9 0.9 4.2 0.4 1.9 1 4.6 0.4 1.9 0.9 4.2 0.4 158 30 202 255 13.7 0 14.4 13.5 06/01/2005 16:30:00 2.2 0.9 4.2 0.4 2.3 1 4.6 0.4 2 1 4.6 0.4 170 24 154 255 13.5 0 13.8 13.3 06/01/2005 16:40:00 2.3 0.6 3.4 0.4 2.3 0.7 3.4 0.4 1.9 0.7 3.4 0.4 202 22 226 255 13.8 0 14.4 13.5 06/01/2005 16:50:00 2.2 0.7 3.8 0.7 2.3 0.7 3.8 0.4 1.9 0.9 3.8 0.4 197 20 191 255 13.5 0 14.1 13.3 06/01/2005 17:00:00 1.7 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.6 0.7 3 0.4 194 22 196 255 13.4 0 13.8 13.3 06/01/2005 17:10:00 1.3 0.7 3 0.4 1.1 0.7 2.6 0.4 1 0.7 3.4 0.4 239 22 201 255 13.6 0.1 14.1 13.3 06/01/2005 17:20:00 1.6 1.3 6.8 0.4 1.4 1.3 6.5 0.4 1.2 1 5.3 0.4 248 27 288 255 13.6 0.1 14.1 13.5 06/01/2005 17:30:00 3.6 1.5 7.2 0.4 3.4 1.5 7.6 0.4 2.9 1.2 6.8 0.7 275 24 235 255 13.5 0 14.1 13.3 06/01/2005 17:40:00 2.9 1.2 6.8 0.4 2.9 1.3 7.2 0.4 2.2 1.3 5.7 0.4 274 24 289 255 13.5 0.1 14.1 13.3 06/01/2005 17:50:00 3.4 1.1 6.1 0.4 3.3 1.1 6.1 0.4 2.5 1.2 5.7 0.4 286 24 268 255 13.2 0.2 13.8 12.7 06/01/2005 18:00:00 3.2 1 5.7 1.1 3 1.1 6.1 0.4 2.5 1 5.3 0.4 282 22 287 255 12.9 0.1 13.3 12.7 06/01/2005 18:10:00 2.9 0.9 4.9 0.4 2.7 1 4.9 0.4 2.1 0.9 4.6 0.4 282 18 284 255 13 0.1 13.5 12.7 06/01/2005 18:20:00 3.5 1.1 5.7 0.7 3.3 1.1 6.1 0.4 2.7 1.1 5.3 0.4 273 20 261 255 12.9 0.1 13.3 12.7 06/01/2005 18:30:00 3.9 1.2 6.8 1.1 3.9 1.1 6.8 1.1 2.8 1.1 5.7 0.7 265 19 269 255 12.9 0 13.3 12.7 06/01/2005 18:40:00 2.4 1.2 5.7 0.4 2.4 1.2 6.1 0.4 1.9 1.1 4.9 0.4 261 28 277 255 13 0.1 13.5 12.7 06/01/2005 18:50:00 2.8 1.7 8 0.4 2.8 1.8 8.4 0.4 2.1 1.6 7.2 0.4 266 33 255 255 13.3 0 13.8 13 06/01/2005 19:00:00 4 1.5 8.4 1.5 4 1.6 8.8 0.7 3.2 1.3 7.2 0.7 265 24 242 255 12.5 0.3 13.5 11.9 06/01/2005 19:10:00 3.5 1.2 7.2 1.1 3.5 1.2 6.8 0.4 2.5 1.1 6.5 0.4 257 26 280 255 11.9 0 12.5 11.7 06/01/2005 19:20:00 2.7 1.2 5.3 0.4 2.6 1.3 5.7 0.4 1.8 1.1 5.3 0.4 251 26 263 255 11.7 0 12.2 11.7 06/01/2005 19:30:00 3.1 0.8 5.3 1.5 3 0.8 5.3 1.1 2.3 0.8 4.6 0.4 242 19 224 255 11.7 0 11.9 11.7 06/01/2005 19:40:00 2.6 1 4.9 0.4 2.4 1.1 5.3 0.4 1.8 1 4.9 0.4 257 21 268 255 11.5 0 11.7 11.4 06/01/2005 19:50:00 2 0.8 4.9 0.4 1.9 0.9 4.9 0.4 1.5 0.8 4.2 0.4 260 23 238 255 11.3 0 11.4 11.4 06/01/2005 20:00:00 1.7 0.8 3.8 0.4 1.6 0.7 3.8 0.4 1.2 0.8 4.2 0.4 263 22 264 255 11.2 0 11.4 11.1 06/01/2005 20:10:00 1.9 0.9 4.6 0.4 1.7 1 4.2 0.4 1.4 0.8 4.2 0.4 242 30 216 255 11.1 0 11.7 11.1 06/01/2005 20:20:00 0.9 0.5 2.3 0.4 0.8 0.5 2.6 0.4 0.6 0.4 2.6 0.4 208 26 226 255 11.1 0 11.4 11.1 06/01/2005 20:30:00 0.7 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 197 15 184 255 10.9 0 11.1 10.9 06/01/2005 20:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 186 14 222 255 10.9 0 10.9 10.9 06/01/2005 20:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 175 15 190 255 10.9 0 10.9 10.9 06/01/2005 21:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 162 1 160 255 10.7 0 10.9 10.6 06/01/2005 21:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 17 133 255 10.4 0 10.6 10.3 06/01/2005 21:20:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 133 9 121 255 10.1 0 10.3 9.8 06/01/2005 21:30:00 1.1 0.4 1.9 0.4 1.1 0.2 1.5 0.7 0.6 0.3 1.5 0.4 158 6 146 255 9.8 0 9.8 9.6 06/01/2005 21:40:00 1 0.4 1.9 0.4 1.6 0.4 2.3 0.7 1.1 0.5 1.9 0.4 175 4 178 255 9.6 0 9.8 9.6 06/01/2005 21:50:00 1.2 0.4 2.3 0.4 1.4 0.6 2.6 0.4 0.9 0.5 2.3 0.4 183 8 179 255 9.4 0 9.6 9.3 06/01/2005 22:00:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.4 2.3 0.4 178 15 215 255 9.1 0 9.3 9 06/01/2005 22:10:00 2.2 0.7 3.4 0.4 2 0.8 3.4 0.4 1.7 0.6 3 0.4 222 15 216 255 8.9 0 9 8.8 06/01/2005 22:20:00 1.6 0.6 3.4 0.4 1.5 0.7 3 0.4 1 0.5 2.3 0.4 214 6 219 255 8.7 0 9 8.5 06/01/2005 22:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 308 45 227 255 8.5 0 8.8 8.5 06/01/2005 22:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 337 7 18 255 8.4 0 8.5 8.5 06/01/2005 22:50:00 0.9 0.6 3 0.4 0.8 0.6 2.6 0.4 0.4 0.2 1.1 0.4 11 6 352 255 8.4 0 8.5 8.5 06/01/2005 23:00:00 0.9 0.7 2.6 0.4 0.6 0.4 1.9 0.4 0.5 0.4 2.3 0.4 359 20 334 255 8.4 0 8.5 8.5 06/01/2005 23:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 353 11 337 255 8.3 0 8.5 8.3 06/01/2005 23:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 20 2 20 255 8.3 0 8.5 8.3 06/01/2005 23:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 20 0 20 255 8.1 0 8.3 8 06/01/2005 23:40:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 16 6 20 255 8.1 0 8.3 8 06/01/2005 23:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 22 8 35 255 8 0 8.3 8 06/02/2005 00:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 7 6 3 255 8 0 8.3 8 06/02/2005 00:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 24 2 12 255 8 0 8.3 8 06/02/2005 00:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 14 55 255 8 0 8.3 8 06/02/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 92 29 255 255 8 0 8.3 8 06/02/2005 00:40:00 0.6 0.5 1.9 0.4 0.6 0.6 2.3 0.4 0.7 0.6 2.3 0.4 140 33 187 255 8.1 0 8.3 8 06/02/2005 00:50:00 0.8 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.8 0.3 1.5 0.4 183 2 188 255 8.1 0 8.3 8.3 06/02/2005 01:00:00 0.8 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.5 0.3 1.1 0.4 177 3 175 255 8.2 0 8.3 8.3 06/02/2005 01:10:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 159 4 164 255 8.1 0 8.3 8.3 06/02/2005 01:20:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 165 2 163 255 8.2 0 8.3 8.3 06/02/2005 01:30:00 1.2 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.6 0.5 1.9 0.4 149 12 153 255 8.1 0 8.3 8.3 06/02/2005 01:40:00 1.2 0.3 1.9 0.7 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 136 3 144 255 8.1 0 8.3 8 06/02/2005 01:50:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 124 12 115 255 8 0 8.3 7.8 06/02/2005 02:00:00 1.3 0.3 1.9 0.4 1 0.4 1.5 0.4 0.4 0.2 1.5 0.4 113 6 115 255 7.8 0 8 7.8 06/02/2005 02:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 107 2 106 255 7.6 0 7.8 7.5 06/02/2005 02:20:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 112 7 106 255 7.4 0 7.5 7.3 06/02/2005 02:30:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 2 108 255 7.5 0 7.5 7.3 06/02/2005 02:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 0 99 255 7.6 0 7.8 7.5 06/02/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 165 72 255 255 7.6 0 7.8 7.5 06/02/2005 03:00:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 266 11 272 255 7.7 0 7.8 7.5 06/02/2005 03:10:00 1.5 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 281 10 270 255 7.8 0 7.8 7.8 06/02/2005 03:20:00 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 279 6 290 255 7.8 0 7.8 7.8 06/02/2005 03:30:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 2 270 255 7.8 0 7.8 7.8 06/02/2005 03:40:00 1.2 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 268 8 259 255 7.8 0 8 7.8 06/02/2005 03:50:00 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 268 11 274 255 7.8 0 8 7.8 06/02/2005 04:00:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 276 13 279 255 7.8 0 8 7.8 06/02/2005 04:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 250 8 251 255 7.8 0 8 7.8 06/02/2005 04:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 228 19 223 255 7.9 0 8 7.8 06/02/2005 04:30:00 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 0.7 0.4 1.9 0.4 219 13 240 255 8 0 8.3 8 06/02/2005 04:40:00 1.3 0.6 2.3 0.4 1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 218 22 211 255 8 0 8.3 8 06/02/2005 04:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 238 18 235 255 8 0 8 7.8 06/02/2005 05:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 254 8 269 255 8 0 8 7.8 06/02/2005 05:10:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.4 0.1 1.1 0.4 236 19 223 255 8 0 8.3 8 06/02/2005 05:20:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 234 9 232 255 8.1 0 8.3 8 06/02/2005 05:30:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 222 22 211 255 8.3 0 8.5 8.3 06/02/2005 05:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 209 22 200 255 8.7 0.2 9 8.5 06/02/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 259 38 277 255 9.8 0.4 10.6 9 06/02/2005 06:00:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 2.3 0.4 261 12 241 255 9.4 0.3 10.3 9 06/02/2005 06:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 277 15 285 255 8.9 0 9 8.8 06/02/2005 06:20:00 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 295 9 271 255 8.7 0 8.8 8.5 06/02/2005 06:30:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 286 8 290 255 8.6 0 8.8 8.5 06/02/2005 06:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 296 15 295 255 8.5 0 8.8 8.5 06/02/2005 06:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.5 0.4 290 6 293 255 8.7 0 9 8.5 06/02/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 287 0 255 255 9.2 0.1 9.6 9 06/02/2005 07:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 284 39 353 255 9.6 0.1 9.8 9.6 06/02/2005 07:20:00 0.4 0.1 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 297 35 299 255 9.8 0 10.1 9.6 06/02/2005 07:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 246 19 252 255 10 0 10.1 9.8 06/02/2005 07:40:00 0.8 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 245 24 240 255 10.1 0 10.3 9.8 06/02/2005 07:50:00 0.9 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.6 0.4 2.3 0.4 253 26 276 255 10.2 0 10.3 10.1 06/02/2005 08:00:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 257 21 264 255 9.8 0 10.1 9.6 06/02/2005 08:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 0.7 0.4 245 12 240 255 10.5 0.2 10.9 10.1 06/02/2005 08:20:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.7 2.6 0.4 261 43 264 255 11 0 11.4 10.9 06/02/2005 08:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 295 64 267 255 10.9 0.2 11.4 10.6 06/02/2005 08:40:00 0.7 0.5 3 0.4 0.6 0.5 2.6 0.4 0.6 0.4 1.9 0.4 300 45 233 255 10.4 0.1 10.6 10.3 06/02/2005 08:50:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 239 22 243 255 11.1 0.7 12.5 10.1 06/02/2005 09:00:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 285 29 284 255 12.1 0 12.7 11.9 06/02/2005 09:10:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1.3 0.7 3 0.4 270 41 280 255 12.5 0 12.7 12.2 06/02/2005 09:20:00 1.5 1 3.8 0.4 1.5 1 3.4 0.4 1.2 1 3.8 0.4 281 35 283 255 12.9 0.2 13.5 12.5 06/02/2005 09:30:00 1.7 0.9 3.4 0.4 1.6 0.9 3.4 0.4 1.6 0.9 3.4 0.4 295 20 296 255 11.9 0.3 12.5 11.1 06/02/2005 09:40:00 1.7 0.9 3.8 0.4 1.5 0.9 3.4 0.4 1.4 0.7 3 0.4 328 26 313 255 12.3 0.5 13 11.1 06/02/2005 09:50:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 1.9 0.8 3.8 0.4 308 17 296 255 13.4 0.4 14.4 12.7 06/02/2005 10:00:00 2.5 1 4.9 0.4 2.4 1 4.9 0.4 2.3 1 4.9 0.4 267 26 253 255 13.6 0.3 14.4 13 06/02/2005 10:10:00 1.7 0.8 3.4 0.4 1.7 0.9 3.8 0.4 1.5 0.9 3.8 0.4 267 32 255 255 12.8 0.3 13.5 12.2 06/02/2005 10:20:00 2.4 0.7 3.8 0.4 2.3 0.7 3.8 0.4 1.8 0.8 3.4 0.4 257 13 255 255 12.2 0.1 12.7 11.9 06/02/2005 10:30:00 2.5 0.9 4.2 0.4 2.4 0.9 4.2 0.4 2.2 0.9 4.2 0.4 289 21 280 255 12.8 0.4 13.5 11.9 06/02/2005 10:40:00 2.2 0.8 4.2 0.4 2 0.8 3.8 0.4 1.7 0.8 3.8 0.4 290 32 321 255 13.9 0.3 14.9 13.3 06/02/2005 10:50:00 1.3 1 4.2 0.4 1.3 1 4.6 0.4 1.2 0.9 4.9 0.4 283 53 273 255 14.2 0.4 15.2 13.3 06/02/2005 11:00:00 2.1 0.6 3.8 0.7 2 0.7 3.4 0.4 1.8 0.8 3.8 0.4 281 22 259 255 13.9 0.2 14.6 13.3 06/02/2005 11:10:00 1.9 1 4.2 0.4 1.8 1 4.6 0.4 1.7 1 4.6 0.4 288 39 270 255 15.5 0.4 16.3 14.6 06/02/2005 11:20:00 2.4 0.8 3.8 0.4 2.3 0.8 3.8 0.4 2 0.8 3.8 0.4 267 26 266 255 14.7 0.5 15.7 13.8 06/02/2005 11:30:00 1.8 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.6 0.9 4.2 0.4 252 35 260 255 14.4 0.4 15.2 13.5 06/02/2005 11:40:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.7 0.4 1.9 0.4 313 79 255 255 15 0.3 15.7 14.6 06/02/2005 11:50:00 2.1 1.1 4.6 0.4 2 1.2 4.9 0.4 1.8 1.2 4.9 0.4 291 56 260 255 15.3 0.4 16.3 14.6 06/02/2005 12:00:00 3.1 0.9 4.9 0.7 3.1 0.9 4.9 0.4 2.6 1 4.9 0.4 218 22 230 255 16.8 0.4 17.7 16 06/02/2005 12:10:00 3.1 1.1 6.1 0.4 3 1.1 5.7 0.4 2.3 1 4.9 0.4 217 19 214 255 16 0.9 17.4 14.6 06/02/2005 12:20:00 2.9 0.9 5.3 0.4 2.8 0.9 4.9 0.4 2.3 0.8 4.2 0.4 210 19 200 255 14.1 0.2 15.2 13.8 06/02/2005 12:30:00 2.5 0.9 4.6 0.4 2.4 1 4.2 0.4 1.8 1 4.2 0.4 227 26 262 255 13.9 0.1 14.6 13.5 06/02/2005 12:40:00 2.4 0.8 4.6 0.4 2.4 0.8 4.2 0.4 1.8 0.8 3.8 0.4 220 27 195 255 15 0.1 15.5 14.6 06/02/2005 12:50:00 2.2 1.1 5.3 0.4 2.1 1.1 5.3 0.4 2.2 1 5.3 0.4 235 33 274 255 15.7 0.3 16.3 15.2 06/02/2005 13:00:00 2.7 1 5.3 0.4 2.6 1 5.3 0.4 2 1 4.9 0.4 280 47 293 255 16.8 0.3 17.1 16 06/02/2005 13:10:00 2.3 1 4.9 0.4 2.1 1 5.3 0.4 1.9 1 5.3 0.4 241 45 229 255 17.3 0 17.7 16.8 06/02/2005 13:20:00 1.5 1 4.2 0.4 1.4 1 4.6 0.4 1.4 0.9 3.8 0.4 278 76 263 255 16.1 0.5 17.4 15.5 06/02/2005 13:30:00 1.7 0.8 3.8 0.4 1.6 1 4.9 0.4 1.4 0.7 3.4 0.4 246 35 243 255 16.8 0.3 17.7 16.3 06/02/2005 13:40:00 2.4 1.2 4.9 0.4 2.4 1.2 5.3 0.4 2 1.2 5.3 0.4 227 45 273 255 17.2 0.3 17.7 16.6 06/02/2005 13:50:00 2.4 1.3 5.3 0.4 2.4 1.3 5.3 0.4 2 1.1 4.6 0.4 282 38 235 255 17.3 0.2 17.7 16.8 06/02/2005 14:00:00 3.3 0.9 5.3 0.4 3.2 0.9 5.3 0.4 2.8 1 4.6 0.4 285 26 316 255 17.8 0.4 18.5 16.8 06/02/2005 14:10:00 3.6 1 6.1 0.7 3.5 1.1 5.7 0.4 3.3 1.2 6.1 0.4 284 23 285 255 18.2 0.2 18.8 17.7 06/02/2005 14:20:00 2.2 1.3 5.3 0.4 2.1 1.3 5.3 0.4 2 1.2 4.9 0.4 258 66 231 255 18.7 0.4 19.4 18.2 06/02/2005 14:30:00 2.8 1.1 5.3 0.4 2.7 1.1 5.3 0.4 2.1 1.1 4.9 0.4 224 27 201 255 17.3 0.7 19.1 16.3 06/02/2005 14:40:00 1.4 0.6 3.4 0.4 1.3 0.6 3 0.4 1.2 0.6 3 0.4 242 33 295 255 15.9 0 16.6 15.5 06/02/2005 14:50:00 1.1 0.6 3 0.4 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 240 21 267 255 15.5 0 16 15.5 06/02/2005 15:00:00 1.8 1.4 6.1 0.4 1.6 1.5 6.8 0.4 1.5 1.3 5.3 0.4 266 28 258 255 15.5 0 16.6 15.5 06/02/2005 15:10:00 3.3 1.4 6.1 0.4 3.3 1.4 6.1 0.4 2.7 1.2 5.7 0.4 233 30 228 255 16.4 0.3 17.1 16 06/02/2005 15:20:00 3 1.2 6.8 0.4 2.9 1.2 6.5 0.4 2.3 1.2 6.1 0.4 252 32 295 255 16.6 0.1 17.1 16.3 06/02/2005 15:30:00 3.2 1.5 7.2 0.4 3.1 1.6 6.8 0.4 2.7 1.5 7.2 0.4 272 39 267 255 17.8 0.6 18.5 16.6 06/02/2005 15:40:00 3.8 1.2 6.8 0.7 3.8 1.2 6.5 0.7 3.3 1.2 6.5 0.4 252 23 273 255 17.8 0.2 18.2 17.1 06/02/2005 15:50:00 3.2 1.6 6.1 0.4 3.2 1.6 6.1 0.4 2.5 1.5 6.1 0.4 263 30 266 255 16.5 0.3 17.1 16 06/02/2005 16:00:00 3.3 1.5 7.2 0.4 3.2 1.6 7.2 0.4 2.6 1.5 6.5 0.4 277 32 249 255 16.8 0.2 17.7 16.6 06/02/2005 16:10:00 3.6 1.3 8 1.1 3.4 1.3 8.4 1.1 2.8 1.4 7.6 0.4 291 24 263 255 18.2 0.2 18.8 17.4 06/02/2005 16:20:00 3.6 1.3 6.8 0.4 3.5 1.3 6.5 0.4 3 1.2 6.1 0.4 249 33 249 255 17.6 0.1 18.2 17.1 06/02/2005 16:30:00 3.8 1.3 6.8 0.7 3.8 1.3 6.8 0.4 3.2 1.2 6.1 0.4 253 27 255 255 17.1 0.2 18 16.8 06/02/2005 16:40:00 3.1 1 6.1 0.4 3.1 1 5.7 0.4 2.2 1.1 4.6 0.4 234 27 235 255 16.5 0.4 17.4 16 06/02/2005 16:50:00 4.2 1.3 7.6 0.7 4 1.3 8 0.4 3.5 1.2 7.2 0.4 263 29 279 255 16.2 0.1 16.8 16 06/02/2005 17:00:00 5.3 1.4 8 1.5 5.2 1.5 8.4 0.4 4.2 1.4 7.6 1.1 255 21 247 255 16 0.2 16.6 15.7 06/02/2005 17:10:00 4 1.3 7.2 0.4 4 1.3 6.8 0.4 3.2 1.2 6.8 0.7 268 26 255 255 15.8 0.1 16.6 15.7 06/02/2005 17:20:00 3.9 1.1 6.8 1.1 3.9 1.1 6.8 1.5 3.3 1.1 6.1 0.7 264 24 286 255 15.5 0 16.3 15.5 06/02/2005 17:30:00 3.4 1.1 5.7 0.7 3.3 1 5.7 0.7 2.6 1 6.1 0.4 252 29 235 255 15.3 0 15.7 15.2 06/02/2005 17:40:00 3.6 1.2 6.8 1.1 3.5 1.3 6.5 0.4 2.9 1.2 6.1 0.4 280 20 296 255 15.2 0 15.5 15.2 06/02/2005 17:50:00 3.3 1.1 5.7 0.7 3.1 1.2 5.7 0.4 2.6 1.1 5.3 0.4 275 27 273 255 15.2 0 15.5 15.2 06/02/2005 18:00:00 3.6 1 6.1 1.1 3.6 1 6.1 0.7 2.9 1.1 6.1 0.4 273 19 282 255 14.9 0.1 15.5 14.6 06/02/2005 18:10:00 2.1 1 4.6 0.4 2.1 1 4.6 0.4 1.6 0.8 3.8 0.4 253 22 267 255 14.3 0.1 14.6 14.1 06/02/2005 18:20:00 2.3 1.2 4.9 0.4 2.1 1.3 4.9 0.4 1.9 1.2 4.9 0.4 246 26 267 255 14.5 0.1 14.9 14.1 06/02/2005 18:30:00 2.5 0.8 4.2 0.4 2.4 0.9 4.6 0.4 1.9 0.8 4.2 0.4 250 15 256 255 14.8 0 15.2 14.6 06/02/2005 18:40:00 3.2 0.7 4.9 1.1 3.2 0.7 4.9 1.5 2.1 0.8 4.2 0.4 242 17 234 255 14.2 0.2 14.9 13.8 06/02/2005 18:50:00 2.6 0.8 4.9 0.7 2.5 0.8 4.6 0.4 1.8 0.9 3.8 0.4 230 16 237 255 13.7 0 14.4 13.5 06/02/2005 19:00:00 2.3 0.7 4.6 0.4 2.3 0.8 4.6 0.4 1.5 0.7 3.8 0.4 225 15 226 255 13.4 0 13.8 13 06/02/2005 19:10:00 2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.2 0.6 3 0.4 213 13 203 255 12.9 0.1 13.3 12.5 06/02/2005 19:20:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 170 27 212 255 12.6 0 13 12.5 06/02/2005 19:30:00 1.1 0.5 1.9 0.4 1 0.5 2.3 0.4 1 0.5 1.9 0.4 129 17 104 255 12.7 0.1 13 12.5 06/02/2005 19:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 125 15 122 255 12.5 0 13 12.5 06/02/2005 19:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 147 5 150 255 12.2 0 12.7 11.9 06/02/2005 20:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 130 17 108 255 11.5 0.2 12.2 11.1 06/02/2005 20:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 127 10 136 255 10.9 0.1 11.1 10.9 06/02/2005 20:20:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 119 10 113 255 10.7 0 11.1 10.6 06/02/2005 20:30:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 129 10 119 255 10.5 0 10.9 10.6 06/02/2005 20:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 129 0 129 255 10.4 0 10.9 10.3 06/02/2005 20:50:00 0.6 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 121 6 116 255 10.3 0.1 10.6 10.3 06/02/2005 21:00:00 0.8 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.3 1.5 0.4 116 0 116 255 10.1 0 10.3 9.8 06/02/2005 21:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 116 0 116 255 9.8 0.1 10.3 9.6 06/02/2005 21:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 127 12 121 255 9.5 0 9.6 9.3 06/02/2005 21:30:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 155 5 147 255 9.1 0 9.3 9 06/02/2005 21:40:00 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 168 11 159 255 8.8 0.1 9 8.5 06/02/2005 21:50:00 1 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 175 12 164 255 8.4 0 8.8 8.3 06/02/2005 22:00:00 1.8 0.5 3 0.7 2.1 0.3 3 1.1 1.5 0.3 2.3 0.7 168 10 143 255 8.1 0.1 8.3 7.8 06/02/2005 22:10:00 1.8 0.5 3 0.7 1.8 0.4 3 1.1 1.5 0.3 2.3 0.7 158 10 146 255 7.8 0 8 7.5 06/02/2005 22:20:00 1.9 0.4 3 1.1 1.9 0.4 2.6 1.1 1.3 0.4 2.6 0.4 143 6 130 255 7.4 0.1 7.8 7.3 06/02/2005 22:30:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 1.1 0.6 0.3 1.5 0.4 142 6 143 255 6.9 0.1 7.3 7 06/02/2005 22:40:00 1.8 0.4 3 0.7 1.7 0.5 3 0.7 0.9 0.4 2.3 0.4 148 12 140 255 6.7 0 7 6.5 06/02/2005 22:50:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1 0.4 2.3 0.4 149 5 147 255 6.4 0.1 6.7 6.2 06/02/2005 23:00:00 2.2 0.5 3.8 0.7 2.2 0.6 3.8 0.7 1.5 0.5 3 0.4 144 6 131 255 6.1 0 6.2 6 06/02/2005 23:10:00 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 2.3 0.4 3.4 1.1 140 7 138 255 5.7 0 6 5.7 06/02/2005 23:20:00 2.6 0.6 3.8 0.7 2.6 0.6 3.8 0.7 1.7 0.6 3 0.4 146 9 139 255 5.5 0 5.7 5.5 06/02/2005 23:30:00 2.2 0.4 3 0.4 2.2 0.4 3 0.4 0.9 0.4 1.9 0.4 151 8 142 255 5.4 0 5.5 5.5 06/02/2005 23:40:00 2.4 0.5 3.4 0.7 2.5 0.4 3.4 1.1 1.6 0.5 3 0.4 160 9 159 255 5.4 0 5.5 5.2 06/02/2005 23:50:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 1.3 0.5 2.6 0.4 155 8 144 255 5.1 0 5.5 5 06/03/2005 00:00:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.5 1.8 0.5 3 0.7 145 8 144 255 4.9 0 5 4.8 06/03/2005 00:10:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 1.9 2.2 0.4 3 1.1 142 6 142 255 4.8 0.1 5 4.5 06/03/2005 00:20:00 2.9 0.4 3.8 1.9 2.9 0.4 4.2 1.9 2.2 0.5 3.4 0.7 141 9 131 255 4.6 0 4.8 4.5 06/03/2005 00:30:00 2.5 0.4 3.4 1.1 2.5 0.4 3.8 1.1 1.5 0.5 2.6 0.4 149 10 142 255 4.6 0 4.8 4.5 06/03/2005 00:40:00 2.5 0.4 3.8 1.5 2.5 0.4 3.8 1.5 1.7 0.5 3 0.4 158 9 164 255 4.4 0 4.5 4.3 06/03/2005 00:50:00 2.2 0.4 3 1.1 2.2 0.3 3 1.5 1.4 0.5 2.3 0.4 165 8 171 255 4.1 0.1 4.5 4 06/03/2005 01:00:00 2 0.6 3 0.7 2.4 0.4 3.4 1.1 1.5 0.5 3 0.4 175 10 167 255 4.1 0 4.3 4 06/03/2005 01:10:00 2.5 0.5 3.4 1.1 2.9 0.4 3.8 1.1 2.3 0.6 3.4 0.4 176 12 172 255 4.1 0 4.3 4 06/03/2005 01:20:00 2.2 0.4 3.4 1.5 3 0.3 3.4 2.3 2.3 0.5 3.4 1.1 181 9 199 255 4.2 0 4.5 4 06/03/2005 01:30:00 2.9 0.7 4.2 1.1 3.2 0.5 4.2 1.5 2.3 0.6 4.2 1.1 165 9 158 255 4.2 0 4.5 4 06/03/2005 01:40:00 2.6 0.7 3.8 0.7 2.7 0.5 3.8 1.1 1.8 0.6 3 0.4 160 8 159 255 4 0 4.3 4 06/03/2005 01:50:00 2.7 0.4 3.4 1.1 2.7 0.3 3.4 1.9 1.8 0.4 2.6 0.7 163 7 158 255 4 0 4.3 3.8 06/03/2005 02:00:00 3 0.3 3.8 2.3 3 0.3 3.8 1.9 2.1 0.4 3.4 1.1 149 6 142 255 3.9 0 4 3.8 06/03/2005 02:10:00 2.8 0.4 3.8 1.9 2.8 0.4 4.2 1.5 2.1 0.4 3 0.7 146 7 142 255 3.9 0 4.3 3.8 06/03/2005 02:20:00 2.5 0.4 3.4 1.1 2.5 0.4 3 1.1 1.8 0.4 2.6 0.7 151 6 148 255 3.8 0 4 3.5 06/03/2005 02:30:00 2.8 0.6 3.8 1.5 2.8 0.6 3.8 1.1 1.8 0.7 3.4 0.4 146 6 143 255 3.6 0 4 3.5 06/03/2005 02:40:00 3.2 0.6 4.2 1.1 3.2 0.6 4.2 1.5 2.4 0.6 3.8 1.1 150 8 142 255 3.6 0 4 3.5 06/03/2005 02:50:00 2.8 0.4 3.4 1.1 2.8 0.4 3.8 1.5 2 0.5 3.4 0.7 160 6 155 255 3.7 0 4.3 3.5 06/03/2005 03:00:00 2.7 0.5 3.8 1.5 2.9 0.3 3.8 1.9 2.1 0.5 3 0.4 159 8 161 255 3.5 0.2 4 3.3 06/03/2005 03:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.9 0.4 3 0.7 152 6 144 255 3.4 0 3.8 3.3 06/03/2005 03:20:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2 0.5 3 0.7 152 5 155 255 3.3 0 3.8 3 06/03/2005 03:30:00 2.9 0.3 3.4 1.9 3 0.3 3.4 1.9 2.2 0.4 3 1.1 141 5 138 255 3.2 0 3.5 3.3 06/03/2005 03:40:00 2.9 0.2 3.8 1.9 3 0.2 3.4 2.3 2.2 0.4 3 1.1 142 5 144 255 3.4 0 3.5 3.3 06/03/2005 03:50:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.1 0.4 3 0.7 139 5 146 255 3.6 0 3.8 3.5 06/03/2005 04:00:00 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 2.1 0.5 3 1.1 137 7 140 255 3.7 0 4 3.5 06/03/2005 04:10:00 2.7 0.4 3.4 1.5 2.8 0.4 3.4 1.5 1.8 0.4 2.6 0.7 134 7 138 255 3.8 0 4 3.8 06/03/2005 04:20:00 2.5 0.6 3.4 0.4 2.6 0.5 3.8 0.7 1.9 0.5 3 0.4 135 8 143 255 4.1 0 4.5 4 06/03/2005 04:30:00 2.6 0.5 3.4 1.1 2.7 0.5 3.8 1.1 1.8 0.5 3 0.4 135 7 134 255 4 0 4.3 3.8 06/03/2005 04:40:00 3.1 0.4 3.8 1.9 3.2 0.5 4.2 1.9 2.3 0.5 3.4 1.1 134 7 133 255 4.6 0.2 5 4.3 06/03/2005 04:50:00 3.3 0.5 4.2 1.5 3.4 0.5 4.2 1.9 2.5 0.5 3.8 1.1 130 8 136 255 5.1 0 5 5 06/03/2005 05:00:00 2.9 0.5 3.8 1.5 3 0.5 3.8 1.5 2.1 0.4 3.4 1.1 130 7 138 255 5.1 0 5.2 5 06/03/2005 05:10:00 3 0.5 4.2 1.5 3.1 0.6 4.2 1.1 2 0.5 3.4 0.7 124 9 122 255 5.1 0 5 5 06/03/2005 05:20:00 3 0.5 3.8 1.5 3.1 0.5 3.8 1.5 2.4 0.4 3.8 1.1 129 8 113 255 5.2 0 5.2 5 06/03/2005 05:30:00 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2.2 0.4 3 1.1 133 6 121 255 5.3 0 5.5 5.2 06/03/2005 05:40:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2 0.4 3 0.4 137 6 134 255 5.3 0 5.7 5.2 06/03/2005 05:50:00 2.6 0.4 3.4 1.1 2.6 0.4 3.4 1.5 1.9 0.5 3.4 0.7 141 6 134 255 5.3 0 5.7 5.2 06/03/2005 06:00:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.1 0.4 3 1.1 139 7 144 255 5.5 0 5.7 5.2 06/03/2005 06:10:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 0.6 0.5 3 0.4 119 18 134 255 6.1 0.2 6.5 5.7 06/03/2005 06:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 147 13 133 255 6.7 0.1 7.3 6.2 06/03/2005 06:30:00 0.9 0.5 2.6 0.4 1 0.5 1.9 0.4 0.6 0.4 1.9 0.4 136 28 113 255 7.9 0.6 9.3 7.3 06/03/2005 06:40:00 0.5 0.3 2.3 0.4 0.5 0.4 2.6 0.4 0.4 0.2 1.5 0.4 176 21 143 255 10.2 0.4 10.6 9.3 06/03/2005 06:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 163 17 152 255 10.6 0 10.6 10.6 06/03/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 172 19 255 255 11.1 0.5 12.2 10.6 06/03/2005 07:10:00 0.6 0.5 2.3 0.4 0.7 0.5 2.6 0.4 0.8 0.7 3 0.4 188 43 203 255 12.6 0.3 13.5 11.9 06/03/2005 07:20:00 1.8 0.7 3.4 0.4 2 0.7 3.8 0.4 1.8 0.7 3.4 0.4 201 26 205 255 12.1 0.3 13 11.7 06/03/2005 07:30:00 1.6 0.8 3.8 0.4 1.7 0.9 4.2 0.4 1.5 0.8 3.4 0.4 222 51 226 255 12.6 0.2 13.3 12.2 06/03/2005 07:40:00 1.8 0.6 3.8 0.4 1.9 0.6 3.8 0.7 1.5 0.6 3.8 0.4 215 18 218 255 13.3 0.2 13.8 13 06/03/2005 07:50:00 1.5 0.5 3.4 0.4 1.6 0.6 3.4 0.4 1.4 0.6 3.4 0.4 217 23 226 255 13.7 0.1 14.4 13.3 06/03/2005 08:00:00 1.5 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.4 0.7 2.6 0.4 216 35 226 255 13.9 0 14.6 13.5 06/03/2005 08:10:00 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.7 0.6 3 0.4 230 27 219 255 13.8 0 14.4 13.5 06/03/2005 08:20:00 1.8 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.7 0.7 3.8 0.4 215 22 268 255 13.7 0.2 14.4 13.3 06/03/2005 08:30:00 2.4 0.7 3.8 0.4 2.4 0.7 3.8 0.4 2.1 0.8 3.8 0.4 221 21 249 255 13.5 0.2 14.1 13 06/03/2005 08:40:00 1.8 0.9 4.2 0.4 1.9 0.9 4.2 0.4 1.5 0.8 3.8 0.4 272 49 278 255 14.2 0 14.6 13.8 06/03/2005 08:50:00 1.4 1 4.6 0.4 1.5 0.9 3.8 0.4 1.3 0.7 3.4 0.4 246 49 287 255 14.6 0.1 14.9 14.4 06/03/2005 09:00:00 1.8 1 3.8 0.4 1.8 1 4.2 0.4 1.7 1 3.8 0.4 261 38 255 255 14.6 0.2 15.2 14.4 06/03/2005 09:10:00 1 0.7 3 0.4 1.1 0.8 3 0.4 1.3 0.6 3 0.4 207 45 250 255 15.1 0.1 15.5 14.6 06/03/2005 09:20:00 1.3 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.5 0.8 3.8 0.4 256 14 240 255 15.1 0.2 15.7 14.6 06/03/2005 09:30:00 1.6 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.2 0.6 2.6 0.4 240 45 256 255 15.7 0 16 15.5 06/03/2005 09:40:00 1.4 1 4.2 0.4 1.5 1 3.8 0.4 1.4 0.9 3.4 0.4 264 49 263 255 15.8 0.3 16.6 15.5 06/03/2005 09:50:00 2.2 1 4.6 0.4 2.2 1 4.9 0.4 1.9 0.6 3.8 0.7 230 26 202 255 16 0 16.3 16 06/03/2005 10:00:00 1.6 0.9 3.4 0.4 1.8 0.8 3.4 0.4 1.7 0.8 3.4 0.4 225 35 196 255 16 0 16.3 15.7 06/03/2005 10:10:00 1.8 1 3.8 0.4 1.8 1 3.8 0.4 1.7 0.8 3.8 0.4 269 51 225 255 16.1 0.1 16.8 15.7 06/03/2005 10:20:00 2 1 4.6 0.4 2 1 4.6 0.4 2 0.9 4.2 0.4 236 33 215 255 16.1 0 16.8 16 06/03/2005 10:30:00 1.8 0.8 3.8 0.4 1.8 0.8 4.6 0.4 1.6 0.7 3.8 0.4 230 33 241 255 16.1 0 16.8 16 06/03/2005 10:40:00 2 1.2 4.9 0.4 2 1.2 4.9 0.4 1.8 1.2 4.2 0.4 267 29 214 255 16.4 0.2 17.1 16 06/03/2005 10:50:00 3.1 1.1 5.7 0.4 3 1.1 5.7 0.4 2.6 1.1 5.7 0.4 242 19 248 255 17 0.1 17.7 16.8 06/03/2005 11:00:00 1.8 1 4.2 0.4 1.6 1 4.2 0.4 1.7 0.9 4.6 0.4 285 38 305 255 17.3 0.3 18.2 16.8 06/03/2005 11:10:00 2.7 1.1 5.3 0.4 2.7 1.1 5.3 0.4 2.4 1.1 4.9 0.4 250 27 255 255 17.3 0.4 18 16.8 06/03/2005 11:20:00 2.3 1 4.6 0.4 2.4 1 4.6 0.4 2.1 1 4.9 0.4 227 47 208 255 17.3 0.1 18 16.8 06/03/2005 11:30:00 2.9 1.2 6.1 0.4 3 1.2 6.1 0.4 2.5 1.2 6.1 0.4 260 38 291 255 17.3 0.1 18 16.8 06/03/2005 11:40:00 3 1.5 8 0.4 2.9 1.5 6.8 0.4 2.3 1.1 4.6 0.4 254 36 304 255 17.5 0.3 18.5 16.8 06/03/2005 11:50:00 2.5 1.1 4.9 0.4 2.5 1.1 5.3 0.4 2.3 1.2 5.3 0.4 267 39 265 255 18.2 0.2 18.8 17.7 06/03/2005 12:00:00 2.6 1.2 6.5 0.4 2.5 1.2 6.5 0.4 2.2 1 5.3 0.4 284 35 262 255 18.8 0.2 19.4 18.2 06/03/2005 12:10:00 3.6 1.1 7.2 0.7 3.5 1.2 7.2 0.4 3.2 1 5.7 0.7 262 26 264 255 18.7 0.2 19.4 18.2 06/03/2005 12:20:00 2.3 0.9 4.6 0.4 2.3 1 4.6 0.4 2.1 0.9 4.2 0.4 275 26 285 255 18.5 0 18.8 18.2 06/03/2005 12:30:00 3.2 1.3 6.1 0.4 3.1 1.3 6.1 0.4 2.8 1.4 6.5 0.4 275 32 251 255 18.7 0.3 19.4 18.2 06/03/2005 12:40:00 3.9 1 5.7 1.5 3.9 1.1 6.1 1.5 3.4 1.3 6.1 0.7 291 23 255 255 18.5 0 19.1 18.2 06/03/2005 12:50:00 2.7 1.3 7.2 0.4 2.7 1.3 6.8 0.4 2.4 1.2 6.5 0.4 284 43 255 255 19.2 0 19.4 18.8 06/03/2005 13:00:00 3.7 1.4 7.2 0.4 3.6 1.3 6.8 0.4 3.2 1.4 6.5 0.4 285 30 271 255 19.7 0.2 20.3 19.4 06/03/2005 13:10:00 3.2 1.3 6.5 0.4 3.1 1.4 6.5 0.4 2.7 1.1 6.1 0.7 276 36 271 255 19.6 0.1 20 19.4 06/03/2005 13:20:00 3.6 1.2 6.8 1.5 3.5 1.2 7.2 1.1 3.2 1.2 7.2 0.4 305 22 295 255 18.9 0.3 19.4 18.5 06/03/2005 13:30:00 3.2 1.5 7.6 0.4 3.1 1.5 6.8 0.4 2.8 1.2 5.7 0.4 295 30 294 255 18 0.1 18.5 17.7 06/03/2005 13:40:00 4 1.2 7.2 1.5 3.8 1.2 7.6 1.1 3.2 1.1 6.8 1.1 308 19 333 255 18 0 18.2 17.7 06/03/2005 13:50:00 3.5 1.2 7.2 1.1 3.5 1.3 7.2 0.7 2.9 1.3 6.8 0.4 295 22 304 255 19 0.3 19.7 18.2 06/03/2005 14:00:00 3.9 1.3 7.2 0.7 3.8 1.3 7.2 0.7 3.1 1.2 5.7 0.4 297 22 313 255 20.3 0.2 20.8 19.4 06/03/2005 14:10:00 3.8 1.3 6.8 0.4 3.8 1.3 7.6 0.4 3 1.4 6.8 0.4 290 35 270 255 20.9 0.3 21.4 20.3 06/03/2005 14:20:00 4.7 1.4 8.8 0.7 4.6 1.5 8.4 1.1 4 1.2 7.2 1.5 306 24 276 255 21.3 0.1 21.7 20.8 06/03/2005 14:30:00 4.7 1.7 8.4 0.4 4.6 1.8 8.4 0.4 3.9 1.9 8.4 0.4 296 24 287 255 20.9 0.2 21.1 20.5 06/03/2005 14:40:00 3.6 1.8 8 0.4 3.5 1.7 8 0.4 2.7 1.4 6.8 0.4 290 64 317 255 20.8 0.4 22 20.5 06/03/2005 14:50:00 7.2 1.7 11.5 2.6 7.1 1.7 11.1 2.6 6.2 1.7 11.1 2.3 111 26 171 255 17.1 1.4 20.8 15.2 06/03/2005 15:00:00 21 31.7 386.8 3.4 27.4 41.2 401.7 3.8 27.7 44.9 396.3 2.6 116 17 122 255 12.7 1.2 15.2 10.9 06/03/2005 15:10:00 5.2 4.9 87.5 2.3 6.1 14.6 256.4 2.6 6.2 22.4 374.4 1.5 122 14 126 255 10.5 0 11.4 10.3 06/03/2005 15:20:00 5.1 0.8 6.8 3 5.2 0.8 6.8 3 3.8 1.7 30.6 1.5 123 13 134 255 10.4 0.1 10.9 10.1 06/03/2005 15:30:00 3.7 1.1 6.5 1.9 3.7 1.1 6.5 1.5 2.7 0.8 5.3 1.1 111 12 110 255 10.4 0.2 11.1 9.8 06/03/2005 15:40:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.5 2.1 0.5 3.4 1.1 124 8 131 255 9.8 0.1 10.6 9.6 06/03/2005 15:50:00 2.1 0.5 3 1.1 2.1 0.6 3 0.7 1.6 0.5 2.6 0.4 132 8 143 255 10 0.2 10.6 9.6 06/03/2005 16:00:00 2.2 0.6 3.8 0.7 2 0.7 3.8 0.4 1.4 0.7 3 0.4 86 39 50 255 10.5 0.1 10.9 10.3 06/03/2005 16:10:00 2.4 0.7 4.2 0.7 2.3 0.8 4.2 0.4 1.5 0.7 3.4 0.4 26 29 4 255 10.8 0.2 11.7 10.6 06/03/2005 16:20:00 2.9 1.2 6.1 0.4 3 1.4 6.5 0.4 2.6 1.2 6.1 0.4 250 76 164 255 11.4 0.2 12.2 11.1 06/03/2005 16:30:00 2.7 0.5 4.2 1.5 2.7 0.5 3.8 1.5 2.1 0.6 3.8 0.4 251 23 255 255 11.8 0.1 12.2 11.7 06/03/2005 16:40:00 2.3 0.8 3.8 0.4 2.3 0.9 4.2 0.4 1.9 0.7 4.6 0.4 196 47 246 255 12.1 0 12.7 11.9 06/03/2005 16:50:00 2.2 0.6 3.8 0.7 2.3 0.5 3.4 1.1 2.1 0.6 3.8 0.4 150 24 123 255 12.5 0 13 12.2 06/03/2005 17:00:00 1.4 0.7 3 0.4 1.6 0.9 3.4 0.4 1.2 0.8 3 0.4 181 19 155 255 13 0.2 13.5 12.7 06/03/2005 17:10:00 1.2 0.6 3 0.4 1.2 0.6 2.6 0.4 1.2 0.4 2.6 0.4 154 17 163 255 13.5 0 13.8 13.3 06/03/2005 17:20:00 1.9 0.5 3 0.7 1.9 0.6 3.4 0.4 1.4 0.7 3 0.4 184 28 153 255 14.2 0.2 14.9 13.5 06/03/2005 17:30:00 2.9 0.9 4.6 0.4 2.9 0.9 4.6 0.4 2.3 0.9 4.9 0.4 227 15 246 255 14.6 0 15.2 14.4 06/03/2005 17:40:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.6 3 0.4 237 19 226 255 14.4 0 14.9 14.4 06/03/2005 17:50:00 1.3 0.8 3 0.4 1.1 0.8 3 0.4 0.8 0.6 2.6 0.4 226 17 229 255 14.3 0 14.9 14.4 06/03/2005 18:00:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 233 17 246 255 14.4 0.1 14.9 14.1 06/03/2005 18:10:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 250 14 244 255 13.9 0 14.4 13.8 06/03/2005 18:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 221 5 226 255 13.9 0 14.4 13.8 06/03/2005 18:30:00 0.6 0.3 1.5 0.4 0.4 0.3 1.5 0.4 0.5 0.3 1.9 0.4 303 38 326 255 13.8 0 14.1 13.5 06/03/2005 18:40:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 346 22 324 255 13.4 0.1 13.8 13 06/03/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 255 255 12.8 0 13.5 12.5 06/03/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 255 255 12.5 0 13 12.5 06/03/2005 19:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 329 28 318 255 12.5 0 13.3 12.5 06/03/2005 19:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 299 0 299 255 13 0.1 13.5 12.7 06/03/2005 19:30:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 307 5 299 255 13.7 0.2 14.4 13.3 06/03/2005 19:40:00 1.6 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.3 0.7 3 0.4 239 19 240 255 13.9 0.1 14.6 13.8 06/03/2005 19:50:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 1.3 0.7 3.4 0.4 211 17 192 255 13.8 0 14.4 13.5 06/03/2005 20:00:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 1.3 0.6 2.6 0.4 204 17 213 255 13.9 0 14.4 13.5 06/03/2005 20:10:00 1.7 0.3 2.3 0.7 1.6 0.4 2.3 0.4 1.1 0.4 2.3 0.4 208 11 214 255 13.3 0.2 14.1 12.7 06/03/2005 20:20:00 2.2 0.7 4.2 0.4 2.2 0.7 4.2 0.4 1.6 0.7 3.8 0.4 206 9 209 255 12.5 0.1 13 12.2 06/03/2005 20:30:00 2.3 0.5 3.4 1.1 2.4 0.5 3.4 0.7 1.6 0.5 3.4 0.4 209 9 209 255 11.9 0.1 12.5 11.7 06/03/2005 20:40:00 1.8 0.4 2.6 0.7 1.8 0.5 3 0.7 1.1 0.4 2.3 0.4 206 9 217 255 11.5 0 11.7 11.4 06/03/2005 20:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.9 0.4 0.5 0.2 1.1 0.4 197 1 205 255 11.2 0 11.4 11.1 06/03/2005 21:00:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 177 16 170 255 10.8 0.1 11.1 10.6 06/03/2005 21:10:00 1.4 0.4 1.9 0.4 1.2 0.6 1.9 0.4 0.8 0.4 1.5 0.4 160 0 160 255 10.4 0.1 11.1 10.3 06/03/2005 21:20:00 1.7 0.2 2.3 0.7 1.6 0.3 2.3 1.1 1 0.4 1.9 0.4 157 3 160 255 10.1 0 10.6 10.1 06/03/2005 21:30:00 1.3 0.3 1.9 0.4 1.1 0.4 1.5 0.4 0.4 0.2 1.1 0.4 153 0 153 255 10 0 10.1 9.8 06/03/2005 21:40:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 153 0 153 255 9.8 0 10.3 9.6 06/03/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 255 255 9.5 0 9.6 9.3 06/03/2005 22:00:00 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 252 66 289 255 9.1 0 9.3 9 06/03/2005 22:10:00 1.1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.4 0.2 1.5 0.4 273 10 282 255 8.7 0 9 8.5 06/03/2005 22:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.3 1.5 0.4 254 22 262 255 8.5 0 8.8 8.5 06/03/2005 22:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 155 8 146 255 8.3 0 8.5 8.3 06/03/2005 22:40:00 1.3 0.3 2.3 0.4 1.1 0.4 2.3 0.4 1 0.4 2.3 0.4 139 8 129 255 8.1 0 8.3 7.8 06/03/2005 22:50:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1 0.4 1.9 0.4 147 6 152 255 7.8 0 8 7.5 06/03/2005 23:00:00 1.6 0.5 2.6 0.4 1.2 0.7 2.3 0.4 0.4 0.2 1.1 0.4 131 17 111 255 7.6 0 7.8 7.5 06/03/2005 23:10:00 2.4 0.3 3 1.5 2.2 0.3 3 1.1 1.1 0.5 2.3 0.4 110 8 102 255 7.5 0 7.8 7.3 06/03/2005 23:20:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 1 0.4 1.9 0.4 100 6 95 255 7.3 0 7.5 7.3 06/03/2005 23:30:00 2.4 0.4 3.4 1.1 2.3 0.5 3.4 1.1 1.7 0.5 3 0.4 128 13 117 255 7.2 0 7.3 7 06/03/2005 23:40:00 3 0.3 3.8 1.9 3 0.4 3.8 1.9 2.1 0.5 3.4 0.7 149 8 142 255 6.9 0 7 6.7 06/03/2005 23:50:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.5 1.7 0.4 2.6 0.4 142 11 147 255 6.8 0 7 6.7 06/04/2005 00:00:00 3.4 0.9 4.9 1.5 3.5 0.9 4.9 1.5 2.7 0.7 4.2 0.4 137 9 154 255 7.1 0.1 7.3 7 06/04/2005 00:10:00 4.4 0.3 4.9 3.4 4.5 0.3 5.3 3.4 3.4 0.5 4.6 1.5 137 6 135 255 7.2 0 7.3 7 06/04/2005 00:20:00 4.5 0.3 5.7 3 4.6 0.3 5.7 3.4 3.5 0.5 4.6 2.3 139 5 140 255 7.3 0 7.3 7.3 06/04/2005 00:30:00 4.2 0.6 5.3 2.3 4.3 0.6 5.3 2.6 3.4 0.7 4.9 1.5 131 9 142 255 7.3 0 7.5 7.3 06/04/2005 00:40:00 4.2 0.7 5.7 2.3 4.3 0.7 5.7 2.3 3.6 0.6 5.3 1.9 131 11 131 255 7.7 0 7.8 7.5 06/04/2005 00:50:00 4.6 0.5 5.7 3 4.7 0.5 5.7 2.6 3.6 0.6 5.3 1.9 136 10 143 255 7.6 0 7.8 7.5 06/04/2005 01:00:00 3.5 0.5 4.9 1.9 3.6 0.5 4.9 1.9 2.4 0.6 3.8 0.4 138 11 151 255 7.4 0 7.5 7.3 06/04/2005 01:10:00 2.7 0.7 4.2 0.7 2.6 0.7 4.2 0.4 1.5 0.7 3 0.4 136 15 133 255 6.9 0 7.3 6.7 06/04/2005 01:20:00 1.9 0.7 3.4 0.4 1.8 0.8 3.4 0.4 1.1 0.7 3 0.4 130 13 113 255 6.7 0 6.7 6.5 06/04/2005 01:30:00 1.4 0.7 3.4 0.4 1.3 0.7 3 0.4 0.6 0.4 2.3 0.4 122 17 119 255 6.2 0 6.7 5.7 06/04/2005 01:40:00 2 0.6 3.4 0.4 2 0.6 3.4 0.4 1.1 0.6 3 0.4 127 12 131 255 5.7 0 6 5.7 06/04/2005 01:50:00 1.7 0.8 3.8 0.4 1.6 0.8 3.8 0.4 0.9 0.6 2.6 0.4 124 15 130 255 5.6 0 5.7 5.2 06/04/2005 02:00:00 2.2 0.5 3.4 0.7 2.1 0.5 3.4 0.4 1.6 0.5 2.6 0.4 130 11 113 255 5.3 0 5.5 5.2 06/04/2005 02:10:00 2.4 0.6 3.8 1.1 2.2 0.6 3.8 0.7 1.7 0.5 3 0.4 128 10 122 255 5.1 0 5.5 4.8 06/04/2005 02:20:00 2.7 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.8 0.6 3 0.4 133 12 138 255 5 0 5 4.8 06/04/2005 02:30:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 0.9 0.5 2.3 0.4 117 11 118 255 5 0 5.2 4.8 06/04/2005 02:40:00 1.7 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1 0.5 2.6 0.4 122 10 133 255 4.7 0 5 4.5 06/04/2005 02:50:00 2 0.6 3.4 0.4 2 0.6 3 0.4 1.3 0.5 2.6 0.4 134 9 140 255 4.5 0 4.8 4.5 06/04/2005 03:00:00 2.3 0.4 3.4 1.1 2.3 0.5 3 1.1 1.5 0.5 2.6 0.4 143 9 148 255 4.4 0 4.8 4.3 06/04/2005 03:10:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 1.1 1.8 0.5 3 0.4 133 9 106 255 4.3 0 4.5 4.3 06/04/2005 03:20:00 2.3 0.6 3.4 0.4 2.2 0.7 3.4 0.4 1.6 0.7 3 0.4 127 13 133 255 4.1 0 4.5 4 06/04/2005 03:30:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.3 0.5 3 0.4 123 11 121 255 4.2 0 4.5 4 06/04/2005 03:40:00 1.7 0.5 3 0.4 1.5 0.6 3 0.4 0.7 0.4 1.9 0.4 115 12 121 255 4 0 4.5 3.8 06/04/2005 03:50:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 0.5 0.3 1.9 0.4 113 8 101 255 4 0 4 3.8 06/04/2005 04:00:00 1.8 0.6 3 0.4 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 114 9 103 255 4 0 4 3.8 06/04/2005 04:10:00 1.9 0.5 2.6 0.4 1.9 0.5 2.6 0.4 1.2 0.4 2.3 0.4 135 9 127 255 4 0 4 3.8 06/04/2005 04:20:00 2 0.4 3 0.7 2 0.4 3 0.7 1.2 0.5 2.6 0.4 141 9 114 255 3.9 0 4 3.8 06/04/2005 04:30:00 2.5 0.5 3.8 1.1 2.5 0.5 3.4 1.1 1.8 0.6 3 0.4 137 13 113 255 3.9 0 4.3 3.8 06/04/2005 04:40:00 2 0.7 3.4 0.4 1.9 0.8 3.4 0.4 1.1 0.6 3 0.4 120 12 106 255 4 0 4.3 4 06/04/2005 04:50:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1 0.5 3 0.4 121 12 113 255 4.2 0 4.3 4.3 06/04/2005 05:00:00 1.9 0.6 3.4 0.4 1.8 0.6 3 0.4 0.7 0.4 2.3 0.4 106 13 115 255 4.4 0 4.5 4.3 06/04/2005 05:10:00 0.5 0.4 1.9 0.4 0.5 0.4 2.3 0.4 0.4 0.1 1.1 0.4 144 43 103 255 4.8 0 5 4.5 06/04/2005 05:20:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 143 8 139 255 5.1 0.2 5.7 4.8 06/04/2005 05:30:00 0.8 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.5 0.3 1.9 0.4 135 20 124 255 5.9 0 6.2 5.7 06/04/2005 05:40:00 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.1 0.4 114 13 103 255 6.7 0.3 7.3 6.2 06/04/2005 05:50:00 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 0.7 0.4 2.3 0.4 96 10 94 255 7.9 0.5 8.8 7.3 06/04/2005 06:00:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 95 18 110 255 9.4 0.2 9.8 8.8 06/04/2005 06:10:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 132 24 96 255 9.7 0.1 10.1 9.3 06/04/2005 06:20:00 0.7 0.5 2.3 0.4 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 132 29 93 255 10.4 0.2 11.1 10.1 06/04/2005 06:30:00 1.3 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 95 14 97 255 11.2 0.1 11.4 10.9 06/04/2005 06:40:00 1 0.6 3.4 0.4 1.1 0.7 3.4 0.4 0.9 0.5 2.6 0.4 74 28 109 255 11.5 0.1 12.2 11.1 06/04/2005 06:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 6 23 0 255 12.3 0.3 13 11.7 06/04/2005 07:00:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 20 35 32 255 12.9 0.1 13.5 12.7 06/04/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 53 255 255 13.1 0.1 13.5 12.7 06/04/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 102 255 255 13.3 0 13.5 13 06/04/2005 07:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 223 53 252 255 13.3 0 13.5 13 06/04/2005 07:40:00 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 283 23 263 255 13.6 0.1 14.4 13.3 06/04/2005 07:50:00 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 300 18 319 255 13.2 0.1 13.5 12.7 06/04/2005 08:00:00 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 292 32 333 255 13.3 0.1 13.8 13 06/04/2005 08:10:00 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 327 15 325 255 13.6 0.5 14.6 12.7 06/04/2005 08:20:00 1.7 0.7 3 0.4 1.7 0.7 3 0.4 1.7 0.7 3.8 0.4 316 23 308 255 14.6 0 15.2 14.4 06/04/2005 08:30:00 1.6 1 3.8 0.4 1.7 1 4.2 0.4 1.4 0.8 3.4 0.4 260 56 220 255 14.9 0.1 15.2 14.6 06/04/2005 08:40:00 1.3 0.9 3.8 0.4 1.4 0.9 3.4 0.4 1.3 0.7 3.4 0.4 236 43 252 255 15.4 0 15.7 15.2 06/04/2005 08:50:00 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.7 0.8 3.4 0.4 247 22 232 255 15.5 0 15.7 15.2 06/04/2005 09:00:00 2.7 1 4.9 0.4 2.7 1 4.6 0.4 2.4 1 4.6 0.4 294 35 327 255 15.5 0.2 16 15.2 06/04/2005 09:10:00 2.8 0.8 4.6 0.4 2.7 0.8 4.9 1.1 2.4 0.8 4.2 0.4 285 22 266 255 15.3 0.2 16 15.2 06/04/2005 09:20:00 2 1 5.3 0.4 1.9 1 4.9 0.4 1.7 0.8 3.8 0.4 279 30 297 255 16.1 0.2 16.8 15.7 06/04/2005 09:30:00 1.8 1 4.2 0.4 1.8 0.9 3.8 0.4 1.5 0.9 4.2 0.4 285 43 312 255 17 0 17.4 16.8 06/04/2005 09:40:00 2 1.1 4.9 0.4 2 1 4.6 0.4 1.9 1.1 4.9 0.4 289 35 285 255 17.1 0 17.7 16.8 06/04/2005 09:50:00 2.7 0.8 4.2 0.4 2.7 0.8 4.6 0.4 2.3 0.8 4.6 0.4 282 26 287 255 17.1 0.2 17.7 16.8 06/04/2005 10:00:00 2.6 1.1 4.9 0.4 2.6 1.1 5.3 0.4 2.2 1 4.9 0.4 275 30 280 255 17.6 0.1 18.2 17.4 06/04/2005 10:10:00 2.6 1.1 5.3 0.4 2.5 1.1 5.3 0.4 2.2 0.9 4.9 0.4 279 41 278 255 17.8 0 18.2 17.4 06/04/2005 10:20:00 2.5 1.1 4.6 0.4 2.5 1 4.6 0.4 2.1 1 4.6 0.4 278 39 255 255 18.2 0.2 18.8 17.7 06/04/2005 10:30:00 2.7 1.1 5.3 0.4 2.5 1.1 5.7 0.4 2.1 1 4.6 0.4 268 35 268 255 18.5 0.2 19.4 18 06/04/2005 10:40:00 3.3 1 5.3 0.4 3.2 1 5.3 0.4 3 1.1 5.3 0.4 277 23 276 255 18.5 0.1 18.8 18.2 06/04/2005 10:50:00 2.5 1 5.3 0.4 2.4 1 4.9 0.4 2.1 0.9 4.9 0.4 264 35 300 255 19.4 0.4 20.3 18.5 06/04/2005 11:00:00 3.6 1.2 6.5 0.4 3.6 1.3 6.5 0.4 3.1 1.2 6.1 0.4 278 29 264 255 19.5 0.1 20 19.1 06/04/2005 11:10:00 3.5 1.1 6.1 0.4 3.4 1.1 6.1 0.4 2.8 1.2 6.1 0.4 299 32 258 255 20.4 0.5 21.4 19.4 06/04/2005 11:20:00 3.8 1.2 6.5 1.1 3.8 1.2 6.5 0.4 3.1 1.2 6.1 0.4 262 28 263 255 20.5 0.5 21.7 20 06/04/2005 11:30:00 3.4 1.1 6.8 1.1 3.4 1 6.8 1.5 2.9 1.2 6.1 0.4 232 28 255 255 20.3 0.4 21.1 19.7 06/04/2005 11:40:00 3.8 1.1 5.7 0.4 3.7 1.1 6.1 0.4 3.1 1.2 6.5 0.4 242 19 253 255 20.3 0 20.5 20 06/04/2005 11:50:00 2.9 1.2 4.9 0.4 2.8 1.2 5.7 0.4 2.3 1.1 5.7 0.4 257 24 237 255 19.5 0 20 19.1 06/04/2005 12:00:00 2.2 1 3.8 0.4 2.2 1 4.2 0.4 2 0.9 4.6 0.4 233 36 189 255 18.9 0 19.7 18.5 06/04/2005 12:10:00 2.4 0.9 4.6 0.7 2.4 1 4.6 0.7 1.9 0.7 3.8 0.4 239 23 233 255 18.7 0 19.1 18.5 06/04/2005 12:20:00 1.9 1 4.9 0.4 1.9 1.1 4.6 0.4 1.7 0.8 3.8 0.4 205 30 246 255 19.2 0 19.7 18.8 06/04/2005 12:30:00 1.7 0.8 3.4 0.4 1.8 0.8 4.2 0.4 1.6 0.7 3.4 0.4 213 33 265 255 18.8 0 19.4 18.5 06/04/2005 12:40:00 1.6 1.2 4.2 0.4 1.5 1.2 4.2 0.4 1.4 1 4.6 0.4 267 38 255 255 19.9 0.4 20.8 19.1 06/04/2005 12:50:00 2 1.2 4.2 0.4 2 1.2 4.2 0.4 1.8 0.9 4.2 0.4 213 47 222 255 20.9 0 21.4 20.8 06/04/2005 13:00:00 1.4 0.9 3.4 0.4 1.4 0.9 3.8 0.4 1.3 0.7 3.8 0.4 233 58 245 255 21.1 0.1 21.4 20.8 06/04/2005 13:10:00 2.2 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.9 1 4.9 0.4 264 32 237 255 21.5 0 21.7 21.4 06/04/2005 13:20:00 1.9 1.1 4.9 0.4 1.9 1.2 4.6 0.4 1.8 0.9 4.2 0.4 252 76 221 255 21.8 0.2 22.3 21.4 06/04/2005 13:30:00 2.4 1.4 5.7 0.4 2.5 1.4 5.7 0.4 2.1 1.2 5.3 0.4 206 58 214 255 21.8 0 22 21.4 06/04/2005 13:40:00 1.3 0.8 3 0.4 1.3 0.9 3 0.4 1.2 0.8 3.4 0.4 208 72 214 255 21.3 0.2 21.7 20.8 06/04/2005 13:50:00 1.8 1.1 4.6 0.4 1.9 1.1 4.6 0.4 1.6 1 4.6 0.4 262 36 270 255 21.2 0 21.4 20.8 06/04/2005 14:00:00 3.2 1 5.3 0.4 3.2 1 5.3 0.4 2.4 0.8 4.6 0.7 219 20 225 255 20.5 0.3 21.1 20 06/04/2005 14:10:00 3.2 1 6.8 1.1 3.3 1 6.1 1.1 2.8 1 6.5 0.4 171 39 115 255 19 0.5 20 18 06/04/2005 14:20:00 4.9 2.7 11.1 0.4 4.9 2.9 21.8 0.4 5.2 7.9 128 1.1 74 38 109 255 14.6 1.4 18 12.2 06/04/2005 14:30:00 1.8 1 4.2 0.4 1.6 1 3.8 0.4 1 0.6 2.6 0.4 325 39 4 255 10.7 0.6 12.2 10.1 06/04/2005 14:40:00 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 2.1 0.8 3.8 0.4 177 39 149 255 10.3 0.3 10.9 9.8 06/04/2005 14:50:00 3 0.5 4.6 1.9 3 0.5 4.6 1.9 2.5 0.5 4.2 1.5 144 8 126 255 11.3 0.3 11.9 10.9 06/04/2005 15:00:00 3.6 0.7 7.2 1.9 3.6 0.8 6.8 1.9 3 0.7 6.5 1.9 135 19 138 255 12.5 0.5 13.8 11.7 06/04/2005 15:10:00 3.1 1.2 7.6 0.4 3.1 1.3 7.2 0.7 2.4 1.3 6.8 0.7 77 24 87 255 14.1 0.1 14.6 13.5 06/04/2005 15:20:00 2.2 0.9 4.6 0.4 2.2 0.9 4.2 0.4 1.7 0.8 3.8 0.4 56 18 60 255 14.4 0.2 14.9 13.8 06/04/2005 15:30:00 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 43 13 40 255 13.7 0 14.4 13.5 06/04/2005 15:40:00 2.1 0.6 4.2 1.1 2.1 0.7 4.6 1.1 1.8 0.6 3.8 0.7 99 21 120 255 13.8 0 14.4 13.5 06/04/2005 15:50:00 2.5 1 5.3 0.4 2.6 1 5.3 0.4 2.1 0.8 4.6 0.4 121 15 107 255 15 0.4 16 14.1 06/04/2005 16:00:00 1.5 0.8 3.4 0.4 1.7 0.9 3.8 0.4 1.6 0.8 3.4 0.4 119 20 119 255 16.8 0.5 17.7 15.7 06/04/2005 16:10:00 1.1 1.1 4.6 0.4 1.2 1.1 4.2 0.4 1.1 1 4.2 0.4 142 56 89 255 18.4 0.3 19.1 17.7 06/04/2005 16:20:00 1.3 1 3.8 0.4 1.4 1.1 4.2 0.4 1.2 1 4.6 0.4 111 26 122 255 18.5 0 18.8 18.2 06/04/2005 16:30:00 1.5 1 4.6 0.4 1.6 1 4.9 0.4 1.6 0.9 3.8 0.4 82 30 96 255 19 0 19.4 18.8 06/04/2005 16:40:00 2.4 1 4.9 0.4 2.5 1 4.9 0.4 2.1 1 4.6 0.4 81 28 92 255 19 0 19.4 18.8 06/04/2005 16:50:00 2.9 1.3 6.8 0.4 3 1.2 6.8 0.4 2.4 1.2 5.3 0.4 99 26 84 255 19 0.1 19.4 18.8 06/04/2005 17:00:00 3.3 1.1 5.7 0.7 3.3 1.1 6.5 0.7 2.7 1 5.7 0.4 109 22 116 255 19 0 19.4 18.8 06/04/2005 17:10:00 2.8 0.8 5.3 1.1 2.8 0.8 4.9 0.4 2.3 0.7 4.6 0.4 111 23 64 255 18.7 0 19.1 18.5 06/04/2005 17:20:00 3 1 5.3 0.7 2.9 1 5.3 0.4 2.3 1.1 4.6 0.4 91 22 84 255 19.2 0.1 19.4 18.8 06/04/2005 17:30:00 1.6 1 4.6 0.4 1.6 1 4.2 0.4 1.4 0.8 3.8 0.4 100 28 133 255 19.7 0.1 20 19.4 06/04/2005 17:40:00 1.6 0.7 3.4 0.4 1.7 0.6 3.4 0.4 1.3 0.7 3 0.4 180 47 211 255 19.3 0 19.4 19.1 06/04/2005 17:50:00 1.8 1 4.6 0.4 1.9 1 4.6 0.4 1.7 1 4.6 0.4 200 36 160 255 19.4 0 19.7 19.1 06/04/2005 18:00:00 4.5 1.4 8.4 1.5 4.6 1.3 8.4 1.5 4 1.4 7.6 1.5 138 35 119 255 18.8 0.3 19.4 18.2 06/04/2005 18:10:00 5.1 1.4 8.8 1.9 5.1 1.4 8.4 1.9 4.4 1.3 7.6 1.5 110 20 110 255 17.5 0.3 18.2 17.1 06/04/2005 18:20:00 3.9 1.3 7.2 0.4 3.9 1.3 7.2 0.4 3.4 1 6.8 1.5 116 19 99 255 16.9 0 17.1 16.8 06/04/2005 18:30:00 4.8 1.2 9.1 1.5 4.6 1.2 8.4 2.3 4.1 1.1 7.6 1.9 113 21 124 255 16.7 0 16.8 16.6 06/04/2005 18:40:00 4.9 1.5 9.1 2.3 4.9 1.5 9.1 2.3 4.2 1.4 8 1.5 110 22 126 255 16.4 0 16.8 16.3 06/04/2005 18:50:00 5 1.5 8.8 2.6 5 1.5 8.8 2.3 4.2 1.5 8 1.9 105 19 91 255 16.6 0 16.8 16.6 06/04/2005 19:00:00 5.8 1.7 11.1 1.9 5.8 1.7 10.7 2.6 5.2 1.6 9.5 2.3 104 19 101 255 16.4 0.1 16.8 16.3 06/04/2005 19:10:00 6 1.7 9.9 2.3 5.9 1.7 9.9 2.3 5.1 1.7 9.1 1.1 103 17 112 255 15.8 0.1 16.3 15.5 06/04/2005 19:20:00 6.6 1.9 11.1 0.7 6.5 1.8 11.1 1.1 5.6 1.7 9.5 1.1 104 20 116 255 15.2 0.1 15.7 15.2 06/04/2005 19:30:00 6.3 1.7 9.9 1.9 6.3 1.6 10.7 2.3 5.2 1.7 9.5 1.5 101 19 122 255 15.1 0 15.7 15.2 06/04/2005 19:40:00 5.7 1.6 9.5 1.9 5.6 1.6 9.1 1.9 4.9 1.3 8.4 2.3 107 21 90 255 15 0 15.5 14.9 06/04/2005 19:50:00 5.9 1.8 10.7 1.1 5.9 1.7 10.3 0.7 4.9 1.6 9.1 1.1 108 20 97 255 14.8 0.1 15.2 14.6 06/04/2005 20:00:00 6.2 1.6 9.5 2.3 6.2 1.6 9.5 1.5 5.2 1.7 9.1 0.7 100 18 114 255 14.6 0 15.2 14.4 06/04/2005 20:10:00 6.2 1.6 10.3 1.9 6.2 1.6 10.3 1.9 5.3 1.7 9.5 0.7 100 18 96 255 14.3 0.1 14.9 14.1 06/04/2005 20:20:00 5.4 1.3 9.1 2.3 5.4 1.3 9.1 2.6 4.4 1.3 8.4 0.4 102 21 111 255 14.2 0.1 14.6 14.1 06/04/2005 20:30:00 6.3 1.5 9.5 1.9 6.2 1.5 9.5 1.9 5.2 1.5 8.8 1.9 104 17 90 255 14.1 0.2 14.6 13.8 06/04/2005 20:40:00 5.9 1.5 9.5 2.3 5.9 1.5 9.5 2.6 4.9 1.5 8.8 1.9 97 21 102 255 13.8 0 14.4 13.5 06/04/2005 20:50:00 6.2 1.4 9.9 2.6 6.1 1.3 9.1 2.6 5.1 1.3 9.1 1.9 106 21 106 255 13.5 0.2 14.1 13.3 06/04/2005 21:00:00 7 1.6 10.7 3 7 1.5 10.7 3.4 5.6 1.5 9.9 2.3 99 16 111 255 13.1 0.1 13.5 12.7 06/04/2005 21:10:00 6.6 1.3 10.7 3.4 6.5 1.3 9.9 3 5.4 1.3 8.4 3 104 17 93 255 12.8 0 13.3 12.7 06/04/2005 21:20:00 5.9 1.6 10.3 2.6 6 1.5 10.7 2.6 5.1 1.5 9.9 1.5 98 17 89 255 12.8 0 13.3 12.7 06/04/2005 21:30:00 5.9 1.3 10.3 3 5.9 1.3 9.9 2.3 4.7 1.4 9.1 1.5 97 21 86 255 12.9 0 13.3 12.7 06/04/2005 21:40:00 6.9 1.7 11.8 3.4 7 1.7 11.8 3 5.8 1.7 10.7 1.5 101 19 124 255 12.9 0 13.3 12.7 06/04/2005 21:50:00 6.4 1.7 11.5 3 6.5 1.6 11.1 3 5.6 1.6 11.1 1.5 101 17 80 255 12.8 0 13.3 12.7 06/04/2005 22:00:00 6.8 1.6 11.5 3 6.7 1.6 11.5 3.8 5.5 1.7 11.1 1.5 98 21 83 255 12.6 0 12.7 12.5 06/04/2005 22:10:00 6.5 1.7 11.1 2.3 6.5 1.7 10.7 2.3 5.1 1.7 9.9 0.7 97 19 108 255 12.5 0 12.5 12.5 06/04/2005 22:20:00 7.5 1.7 11.8 3.4 7.5 1.7 12.2 3.8 6.1 1.7 10.7 2.3 97 18 80 255 12.5 0 12.7 12.5 06/04/2005 22:30:00 7.7 1.8 12.2 3.4 7.6 1.7 11.5 3.4 6.3 1.8 10.7 1.9 103 17 99 255 12.3 0 12.5 12.2 06/04/2005 22:40:00 6.7 1.8 10.7 2.6 6.6 1.7 11.1 1.9 5.5 1.7 9.5 1.1 108 21 108 255 12.2 0 12.2 12.2 06/04/2005 22:50:00 6.1 1.8 11.5 1.9 6.1 1.7 11.1 1.5 5.1 1.6 9.1 1.1 114 23 99 255 12 0 12.5 11.9 06/04/2005 23:00:00 6.5 2 11.8 2.3 6.5 1.9 12.2 3 5.5 1.8 11.5 1.9 113 22 103 255 11.9 0 11.9 11.9 06/04/2005 23:10:00 7.4 2.1 13.3 2.3 7.3 2 13.3 1.9 6 2.1 11.8 0.7 108 23 103 255 11.9 0 11.9 11.9 06/04/2005 23:20:00 7.2 1.7 11.8 3.4 7.2 1.6 11.5 3 5.6 1.9 10.7 1.1 107 20 105 255 11.9 0 12.2 11.7 06/04/2005 23:30:00 7.1 1.8 12.2 3.4 7.1 1.7 11.8 3 6 1.7 10.7 1.9 109 18 122 255 11.7 0 11.9 11.7 06/04/2005 23:40:00 6.3 1.8 11.1 1.5 6.1 1.8 10.7 1.9 5.2 1.7 9.1 1.1 114 21 105 255 11.7 0 11.9 11.7 06/04/2005 23:50:00 5.9 1.6 9.9 1.5 5.9 1.6 9.9 2.3 5.1 1.5 9.1 1.5 111 19 108 255 11.7 0 11.9 11.7 06/05/2005 00:00:00 5.7 1.5 9.9 1.5 5.6 1.5 10.3 1.9 4.7 1.4 8.4 1.9 107 18 81 255 11.9 0 11.9 11.7 06/05/2005 00:10:00 5.3 1.3 8.8 2.3 5.2 1.3 8.8 1.9 4.4 1.5 8.8 1.5 109 21 104 255 12 0 12.2 11.9 06/05/2005 00:20:00 4.5 1.6 8.8 0.4 4.4 1.7 9.5 0.4 3.6 1.5 8 0.7 98 27 90 255 11.9 0 12.2 11.7 06/05/2005 00:30:00 2.8 1.3 6.1 0.4 2.6 1.4 6.1 0.4 2.1 1.2 5.7 0.4 78 33 111 255 11.7 0 11.9 11.7 06/05/2005 00:40:00 5 1.6 9.9 1.5 4.9 1.6 9.9 0.7 4 1.5 7.6 0.4 116 26 105 255 11.7 0 11.9 11.7 06/05/2005 00:50:00 5.9 1.8 10.3 1.9 5.9 1.7 10.7 1.9 4.7 1.7 8.8 1.1 104 22 111 255 11.8 0.1 11.9 11.7 06/05/2005 01:00:00 5.6 1.7 9.5 1.9 5.5 1.7 9.5 1.9 4.8 1.5 8.8 1.5 106 20 80 255 11.9 0 11.9 11.9 06/05/2005 01:10:00 5.4 1.7 9.9 0.7 5.2 1.8 9.9 0.7 4.2 1.6 7.6 0.4 110 26 89 255 11.7 0 11.9 11.7 06/05/2005 01:20:00 5.4 1.3 9.1 1.9 5.2 1.3 8.8 2.3 4.3 1.4 7.6 0.7 113 19 108 255 11.7 0 11.9 11.7 06/05/2005 01:30:00 5.2 1.5 8.8 2.3 5.2 1.5 8.8 1.9 4.4 1.5 8.8 1.1 103 19 88 255 11.7 0 11.7 11.7 06/05/2005 01:40:00 4.8 1 6.8 1.5 4.7 1.1 6.8 1.9 3.7 1.1 6.1 1.1 100 19 106 255 11.5 0.1 11.7 11.1 06/05/2005 01:50:00 3.8 1.3 6.8 0.7 3.7 1.3 6.8 0.7 3.1 1.2 6.5 0.4 87 17 120 255 11.1 0 11.1 10.9 06/05/2005 02:00:00 4.3 1.1 7.6 1.9 4.3 1.2 7.6 1.5 3.4 1.2 6.8 0.7 94 19 104 255 10.8 0 11.1 10.6 06/05/2005 02:10:00 4.8 1.1 8 2.6 4.7 1.1 7.6 2.3 3.8 1.2 6.8 1.1 97 17 88 255 10.7 0 10.9 10.6 06/05/2005 02:20:00 3.9 1.2 7.6 0.4 3.7 1.3 8 0.4 3.2 1.2 7.6 0.4 102 22 100 255 10.6 0 10.6 10.6 06/05/2005 02:30:00 3.2 1.1 6.5 0.4 3 1.2 6.1 0.4 2.5 1.2 6.1 0.4 91 26 115 255 10.4 0 10.6 10.3 06/05/2005 02:40:00 3.1 1 5.7 0.4 2.8 1.1 5.7 0.4 2.4 1 4.9 0.4 75 17 81 255 10.1 0 10.3 10.1 06/05/2005 02:50:00 3.1 0.6 4.6 1.9 3 0.6 4.6 1.5 2.1 0.7 3.8 0.4 65 14 73 255 10 0 10.1 9.6 06/05/2005 03:00:00 2.9 0.8 4.2 0.4 2.6 0.8 4.2 0.4 1.8 0.9 4.2 0.4 84 16 87 255 9.5 0 9.8 9.3 06/05/2005 03:10:00 3.1 0.5 4.2 1.5 2.9 0.6 3.8 1.1 2.2 0.7 3.4 0.4 94 11 80 255 9.3 0 9.6 9 06/05/2005 03:20:00 3.3 0.5 4.9 1.9 3.2 0.5 4.6 1.9 2.2 0.6 3.8 0.7 96 9 102 255 8.9 0 9.3 8.8 06/05/2005 03:30:00 3.1 0.5 4.6 1.5 2.9 0.6 4.6 1.5 1.8 0.7 4.2 0.4 110 13 94 255 8.6 0 8.8 8.5 06/05/2005 03:40:00 2.3 0.8 4.9 0.4 2 0.9 4.6 0.4 1.2 0.7 3.8 0.4 117 17 68 255 8.8 0.1 9 8.5 06/05/2005 03:50:00 1.7 0.9 4.2 0.4 1.4 0.9 4.2 0.4 0.9 0.6 3.4 0.4 108 18 110 255 8.5 0.2 9 8.3 06/05/2005 04:00:00 2.3 0.5 4.2 0.7 2.1 0.6 3.8 0.7 1.4 0.5 3 0.4 106 10 109 255 8.2 0.1 8.5 7.8 06/05/2005 04:10:00 2.8 0.7 4.6 1.1 2.5 0.8 4.2 0.7 1.7 0.7 4.2 0.4 107 12 105 255 7.4 0.1 7.8 7.3 06/05/2005 04:20:00 2.1 0.7 4.2 0.4 1.8 0.8 3.8 0.4 0.9 0.6 2.6 0.4 105 15 108 255 7.7 0.1 8.3 7.5 06/05/2005 04:30:00 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 106 10 98 255 7.9 0 8.3 7.5 06/05/2005 04:40:00 1.3 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.1 1.1 0.4 97 7 98 255 7.4 0.1 7.8 7.3 06/05/2005 04:50:00 2.2 0.5 3.4 1.1 2 0.5 3 0.7 0.9 0.4 1.9 0.4 89 5 88 255 7.3 0 7.5 7.3 06/05/2005 05:00:00 1.4 0.3 2.3 0.7 1.1 0.4 2.3 0.4 0.6 0.3 1.5 0.4 70 20 94 255 7.5 0 7.8 7.3 06/05/2005 05:10:00 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0 0.7 0.4 44 1 47 255 7.8 0.1 8 7.5 06/05/2005 05:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 44 255 8.3 0.1 8.5 8 06/05/2005 05:30:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 71 6 73 255 9 0.5 10.1 8.5 06/05/2005 05:40:00 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.1 0.4 86 15 106 255 10.9 0.3 11.4 10.1 06/05/2005 05:50:00 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 76 8 76 255 11.7 0.4 12.7 11.1 06/05/2005 06:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 39 23 69 255 13.5 0.4 14.6 12.7 06/05/2005 06:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 25 12 12 255 13.5 0.4 14.4 12.7 06/05/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 0 255 255 12.5 0.2 13.3 11.9 06/05/2005 06:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 16 8 17 255 13.4 0.5 14.4 12.5 06/05/2005 06:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0 5 359 255 14.2 0.2 14.9 13.8 06/05/2005 06:50:00 0.8 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 350 22 351 255 14.9 0.2 15.2 14.6 06/05/2005 07:00:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 6 18 342 255 15.2 0.1 15.7 15.2 06/05/2005 07:10:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 344 14 349 255 15.7 0 16 15.5 06/05/2005 07:20:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 11 13 355 255 15.6 0 16 15.5 06/05/2005 07:30:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 0.4 1.5 0.6 2.6 0.4 1 12 17 255 15.9 0 16.3 15.5 06/05/2005 07:40:00 1.5 0.5 3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 356 15 340 255 16 0 16.3 15.7 06/05/2005 07:50:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.1 0.5 2.3 0.4 2 22 347 255 16.4 0.1 16.8 16.3 06/05/2005 08:00:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.6 0.4 21 17 5 255 16.2 0 16.8 16 06/05/2005 08:10:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 36 28 30 255 16.3 0.2 17.1 16 06/05/2005 08:20:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 33 22 8 255 16.8 0.1 17.4 16.6 06/05/2005 08:30:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.4 2.3 0.4 47 35 52 255 17 0 17.4 16.8 06/05/2005 08:40:00 1.3 0.6 2.6 0.4 1.1 0.6 3 0.4 1.2 0.6 2.6 0.4 40 43 56 255 16.7 0.2 17.4 16.6 06/05/2005 08:50:00 1.1 0.5 2.6 0.4 1 0.5 2.3 0.4 1 0.6 2.6 0.4 1 53 32 255 17.2 0.1 18 16.8 06/05/2005 09:00:00 1.5 0.8 3.4 0.4 1.3 0.8 3 0.4 1.3 0.6 2.6 0.4 308 21 304 255 17.5 0.1 18 17.1 06/05/2005 09:10:00 1.3 0.7 3.4 0.4 1.1 0.8 3.4 0.4 1.1 0.6 2.6 0.4 324 66 247 255 17.8 0.3 18.5 17.1 06/05/2005 09:20:00 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.8 0.8 3.4 0.4 294 17 327 255 18.2 0.1 18.8 17.7 06/05/2005 09:30:00 1.6 0.6 3.8 0.4 1.4 0.7 3.8 0.4 1.3 0.6 3.4 0.4 319 51 289 255 18.2 0 18.5 18 06/05/2005 09:40:00 1.6 0.9 3.4 0.4 1.5 1 3.4 0.4 1.2 0.7 3.4 0.4 224 53 268 255 18.5 0.1 19.1 18.2 06/05/2005 09:50:00 1.7 0.9 3.4 0.4 1.6 0.9 3.4 0.4 1.2 0.8 3 0.4 286 79 321 255 19.2 0.2 20 18.5 06/05/2005 10:00:00 2.9 1.1 5.3 0.4 2.8 1.1 5.3 0.4 2.5 1.2 5.7 0.4 293 36 306 255 18.8 0.4 19.7 18.2 06/05/2005 10:10:00 2.3 0.8 4.2 0.4 2.2 0.9 4.6 0.4 1.9 0.9 4.2 0.4 301 38 327 255 19 0.2 19.4 18.5 06/05/2005 10:20:00 2.9 1.1 6.8 0.7 2.9 1.1 6.8 0.4 2.5 1.1 6.1 0.4 286 33 294 255 19.5 0.1 20 19.1 06/05/2005 10:30:00 3.1 0.6 5.3 1.5 3 0.7 4.9 1.5 2.6 0.6 4.2 1.1 310 22 293 255 19.2 0 19.4 19.1 06/05/2005 10:40:00 2.2 0.8 4.6 0.4 2 0.9 4.6 0.4 1.6 0.9 3.8 0.4 294 43 268 255 19.9 0.3 20.3 19.1 06/05/2005 10:50:00 2.8 1 5.7 0.7 2.7 1 4.9 0.4 2.3 1 5.3 0.4 282 38 336 255 20 0 20.5 19.7 06/05/2005 11:00:00 2.1 0.9 4.6 0.4 2 0.8 4.6 0.4 1.8 0.7 3.4 0.4 267 45 356 255 19.8 0.2 20.3 19.4 06/05/2005 11:10:00 2.4 1.3 5.7 0.4 2.3 1.3 5.7 0.4 2 1.3 5.3 0.4 290 33 303 255 19.6 0.1 20.5 19.4 06/05/2005 11:20:00 2.9 0.9 5.3 1.1 2.7 1 5.3 0.7 2.3 1 4.6 0.4 311 21 307 255 20.3 0.4 21.1 19.7 06/05/2005 11:30:00 3.5 1.2 6.1 1.1 3.3 1.2 6.1 0.4 2.9 1.1 5.7 0.7 304 18 271 255 20.4 0.2 21.1 20 06/05/2005 11:40:00 2.7 0.9 5.7 0.4 2.5 0.9 4.9 0.4 2.1 0.8 4.9 0.4 324 28 18 255 20.6 0.2 21.4 20.3 06/05/2005 11:50:00 3.5 1 5.7 1.1 3.2 1 5.3 0.4 2.6 1 5.3 0.7 314 32 319 255 21.3 0 21.7 21.1 06/05/2005 12:00:00 3.2 0.9 5.7 0.7 3 0.8 5.7 0.7 2.7 0.9 4.6 0.4 295 29 257 255 20.9 0 21.4 20.8 06/05/2005 12:10:00 2.7 1.5 6.8 0.4 2.6 1.5 6.1 0.4 2.2 1.3 5.7 0.4 287 64 320 255 21.5 0.2 22.3 21.1 06/05/2005 12:20:00 3.2 1.3 6.5 0.4 3 1.5 6.1 0.4 2.6 1.3 5.7 0.4 288 51 324 255 21.7 0.2 22.3 21.1 06/05/2005 12:30:00 4 1 6.1 1.1 3.8 1.1 6.1 0.4 3.2 1.1 6.1 0.7 309 32 230 255 22.1 0.1 22.6 21.7 06/05/2005 12:40:00 3.2 1 5.7 0.4 3 1.1 5.3 0.4 2.7 1 4.9 0.4 275 30 270 255 21.6 0 22 21.4 06/05/2005 12:50:00 3.6 1.1 7.2 0.7 3.4 1.2 8 0.4 2.9 1.2 5.7 0.7 300 32 305 255 22.2 0.2 22.6 21.7 06/05/2005 13:00:00 4 1.2 6.8 1.9 4 1.2 6.8 1.9 3.6 1.3 6.8 1.1 290 22 289 255 21.2 0.4 22.3 20.5 06/05/2005 13:10:00 3.8 1.1 6.1 1.5 3.6 1.1 6.5 1.1 3.2 1.2 6.5 0.7 312 24 313 255 22.6 0.3 23.5 21.7 06/05/2005 13:20:00 4.1 1.3 7.2 0.4 4 1.3 7.2 0.7 3.4 1.5 7.2 0.7 298 20 287 255 22.4 0.7 23.5 20.8 06/05/2005 13:30:00 3.8 1 6.5 0.7 3.7 1.1 6.5 0.4 3 1.1 6.5 0.7 282 21 274 255 20.8 0.1 21.1 20.5 06/05/2005 13:40:00 5 1.3 8 1.9 5 1.4 7.6 1.9 4.2 1.5 8 0.4 290 21 304 255 20.4 0.1 20.8 20 06/05/2005 13:50:00 4.3 1.3 6.8 1.1 4.2 1.4 6.8 0.7 3.5 1.5 6.5 0.4 288 22 298 255 19.7 0.6 20.8 18.8 06/05/2005 14:00:00 3.9 0.9 6.1 1.5 3.9 1 6.5 1.1 3.1 0.9 4.9 0.7 283 19 281 255 18.8 0 19.4 18.5 06/05/2005 14:10:00 3 1 5.7 0.4 2.9 1 5.7 0.4 2.4 1 4.9 0.4 275 23 253 255 19.6 0.3 20.3 18.8 06/05/2005 14:20:00 2.5 0.8 4.9 0.7 2.3 1 5.7 0.4 2 0.8 4.6 0.4 271 28 262 255 19.1 0.1 20 18.8 06/05/2005 14:30:00 2.8 1 4.9 0.4 2.5 1.1 4.9 0.4 2.1 0.8 4.6 0.4 301 30 299 255 19.5 0.1 20.3 19.1 06/05/2005 14:40:00 2.8 1 5.7 0.7 2.6 1.2 5.7 0.4 2 1 4.2 0.4 302 24 268 255 20 0.1 20.5 19.7 06/05/2005 14:50:00 1.7 0.6 3.4 0.4 1.5 0.8 3.4 0.4 1.4 0.6 3 0.4 259 41 215 255 19.5 0 20 19.1 06/05/2005 15:00:00 1.1 0.7 3 0.4 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 271 86 211 255 21.3 0.6 22.3 20 06/05/2005 15:10:00 2 0.9 4.6 0.4 1.7 0.9 4.2 0.4 1.7 0.7 3.4 0.4 283 43 290 255 22 0.3 23.5 21.7 06/05/2005 15:20:00 3 0.8 5.3 0.7 2.8 0.9 5.3 0.4 2.3 0.9 4.2 0.4 304 27 309 255 21.8 0.7 23.5 20.8 06/05/2005 15:30:00 3.5 1 5.7 0.7 3.4 1.1 5.7 0.4 2.9 1 5.7 0.4 264 32 279 255 21.3 0.3 22.3 20.8 06/05/2005 15:40:00 2.7 1.3 6.1 0.4 2.5 1.3 6.1 0.4 2 1.2 5.3 0.4 305 49 4 255 22.2 0.1 22.9 22 06/05/2005 15:50:00 3.4 1.1 6.5 0.7 3.1 1.1 6.5 0.4 2.5 1.2 5.3 0.4 313 36 355 255 22.2 0.5 22.9 21.1 06/05/2005 16:00:00 3.7 1.2 7.2 0.4 3.6 1.2 7.6 0.7 3.1 1.3 6.8 0.4 288 32 273 255 21.7 0.4 22.6 21.1 06/05/2005 16:10:00 5.4 1.6 9.1 1.1 5.3 1.6 8.8 1.9 4.6 1.6 9.1 1.1 287 24 297 255 22.2 0 22.9 21.7 06/05/2005 16:20:00 4.8 1.7 10.3 1.1 4.8 1.7 10.3 1.1 3.9 1.7 9.1 0.4 287 24 306 255 20.8 0.4 21.7 20 06/05/2005 16:30:00 4.6 1.7 10.7 1.1 4.4 1.7 10.3 0.7 3.6 1.5 8.4 1.1 285 22 231 255 19.5 0.2 20.3 19.1 06/05/2005 16:40:00 5.4 1.8 9.5 0.7 5.3 1.9 9.5 0.4 4.2 1.8 9.5 0.7 280 22 231 255 18.6 0.2 19.1 18.2 06/05/2005 16:50:00 5.3 1.3 9.9 2.6 5.2 1.3 9.9 2.6 4.2 1.3 9.5 1.5 272 22 255 255 18 0.1 18.2 17.7 06/05/2005 17:00:00 4.9 1.7 9.5 1.5 4.9 1.8 9.1 0.4 3.6 1.7 8.4 0.4 260 26 276 255 17.7 0.2 18.2 17.1 06/05/2005 17:10:00 4.4 1.5 8 1.1 4.4 1.5 8.8 0.4 3.1 1.6 6.8 0.4 268 27 272 255 16.9 0.1 17.7 16.6 06/05/2005 17:20:00 4.3 2.2 9.9 0.7 4.3 2.2 9.5 0.4 3.3 1.7 8.4 0.4 258 24 266 255 16.4 0 16.8 16.3 06/05/2005 17:30:00 3.3 1.1 6.5 1.1 3.2 1.3 7.2 0.4 2.3 1.1 6.1 0.4 250 33 255 255 16.1 0 16.6 16 06/05/2005 17:40:00 3.3 1.9 8 0.4 3.1 2 8 0.4 2.7 1.8 7.6 0.4 273 35 246 255 16.1 0 16.3 16 06/05/2005 17:50:00 1.6 0.7 3.8 0.4 1.3 0.8 3.4 0.4 1 0.5 2.6 0.4 0 45 81 255 15.9 0 16.3 15.7 06/05/2005 18:00:00 4 1 5.7 1.9 3.9 1.1 6.1 1.1 3.2 1 5.7 1.1 51 15 74 255 15.4 0.2 16 15.2 06/05/2005 18:10:00 2.8 1.1 4.9 0.7 2.6 1.2 4.9 0.4 2.4 1 4.6 0.4 78 24 62 255 14.6 0.2 15.5 14.1 06/05/2005 18:20:00 4.2 0.8 6.1 2.3 4.1 0.8 6.5 1.9 3.6 0.8 5.7 1.9 107 13 91 255 13.6 0.3 14.6 13 06/05/2005 18:30:00 3.7 0.9 5.7 1.1 3.6 1 6.1 0.7 3.1 0.8 4.9 1.1 95 16 124 255 12.7 0 13 12.5 06/05/2005 18:40:00 4 0.9 7.2 1.5 3.9 1 7.2 1.5 2.8 0.8 4.9 1.5 117 20 121 255 12.4 0 12.7 12.2 06/05/2005 18:50:00 3.5 1.1 6.8 0.7 3.4 1.1 6.5 0.7 3 1 6.1 0.4 131 23 116 255 12.2 0.1 12.7 11.9 06/05/2005 19:00:00 3.5 1.5 6.8 0.4 3.3 1.5 6.8 0.4 2.7 1.3 5.7 0.4 127 22 110 255 11.9 0.2 12.5 11.7 06/05/2005 19:10:00 4.6 0.7 6.1 2.6 4.5 0.7 6.1 2.3 3.6 0.8 5.7 1.5 103 12 113 255 11.7 0 12.2 11.7 06/05/2005 19:20:00 3.9 0.8 5.7 1.9 3.7 0.9 5.7 1.5 3 0.9 5.3 1.1 99 15 94 255 11.6 0 11.9 11.4 06/05/2005 19:30:00 3.9 0.5 5.7 2.6 3.8 0.6 5.7 2.3 3 0.7 4.6 1.1 92 9 84 255 11.5 0 11.9 11.4 06/05/2005 19:40:00 3.8 0.8 5.7 1.1 3.6 0.9 5.7 1.1 2.9 0.8 4.9 0.7 76 17 64 255 11.5 0 11.9 11.4 06/05/2005 19:50:00 2.9 0.7 4.6 1.1 2.7 0.8 4.6 0.4 2.3 0.7 4.2 0.4 72 15 88 255 11.5 0 11.9 11.4 06/05/2005 20:00:00 2.8 0.6 4.6 1.1 2.5 0.7 4.2 0.4 1.9 0.8 3.8 0.4 64 13 62 255 11.6 0 11.9 11.4 06/05/2005 20:10:00 1.4 0.7 3 0.4 1 0.7 3 0.4 0.6 0.4 1.9 0.4 72 12 43 255 11.7 0 12.2 11.7 06/05/2005 20:20:00 2 0.5 3 1.1 1.6 0.5 2.6 0.4 1 0.6 3 0.4 81 10 96 255 11.7 0 11.9 11.7 06/05/2005 20:30:00 1.1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.9 0.4 92 20 61 255 11.7 0 12.2 11.7 06/05/2005 20:40:00 2.1 0.4 3 1.1 1.8 0.4 3 0.7 1.4 0.5 2.6 0.4 134 12 140 255 11.7 0 11.9 11.7 06/05/2005 20:50:00 2.3 0.4 3 1.1 2.1 0.4 3 0.7 1.7 0.4 2.6 0.7 158 11 158 255 11.7 0 11.7 11.7 06/05/2005 21:00:00 3.1 0.6 4.6 1.5 3 0.6 4.2 1.9 2.2 0.7 3.8 0.7 163 9 168 255 11.6 0 11.9 11.7 06/05/2005 21:10:00 3.5 0.5 4.6 2.3 3.4 0.5 4.6 2.3 2.8 0.6 4.6 1.1 146 9 151 255 11.6 0 12.2 11.7 06/05/2005 21:20:00 3 0.8 4.9 1.1 2.7 0.8 4.6 1.1 2.1 0.8 4.2 0.4 135 15 148 255 11.5 0 11.9 11.4 06/05/2005 21:30:00 2.8 0.6 3.8 1.1 2.6 0.6 4.2 1.1 1.8 0.7 3.8 0.4 142 13 162 255 11.3 0 11.9 11.1 06/05/2005 21:40:00 3 0.5 4.6 1.5 2.8 0.6 4.2 1.5 2.1 0.6 3.8 0.7 130 13 136 255 11.1 0 11.4 10.9 06/05/2005 21:50:00 2.8 0.6 4.6 1.5 2.5 0.7 4.2 0.7 2.1 0.7 3.4 0.4 124 12 114 255 10.9 0 11.1 10.9 06/05/2005 22:00:00 2.2 0.5 3.4 1.1 2 0.5 3.4 0.7 1.5 0.5 3 0.4 123 13 112 255 10.5 0 10.9 10.3 06/05/2005 22:10:00 2.3 0.5 3.4 1.1 2 0.5 3 0.7 1.3 0.6 2.6 0.4 124 13 113 255 10.2 0 10.3 9.8 06/05/2005 22:20:00 2.7 0.5 4.6 1.5 2.5 0.6 4.2 0.7 1.5 0.5 2.6 0.4 100 12 91 255 9.6 0.1 10.1 9.3 06/05/2005 22:30:00 3.3 0.5 4.6 2.3 3.1 0.5 4.6 1.9 2.2 0.6 3.8 0.7 69 10 68 255 9.3 0 9.3 9 06/05/2005 22:40:00 3.6 0.5 4.9 2.3 3.5 0.6 4.9 1.9 2.5 0.6 4.2 1.1 67 9 60 255 9.2 0 9.3 9 06/05/2005 22:50:00 3.7 0.6 5.3 2.3 3.6 0.6 5.3 1.9 2.6 0.7 4.2 0.7 63 11 53 255 9.3 0 9.3 9.3 06/05/2005 23:00:00 3.9 0.6 5.7 2.3 3.8 0.7 5.3 1.9 2.7 0.7 4.2 1.1 52 12 52 255 9.5 0.1 9.8 9.3 06/05/2005 23:10:00 3.9 0.7 5.7 1.9 3.8 0.8 5.7 1.5 2.6 0.8 4.6 0.7 55 12 52 255 9.6 0 9.8 9.3 06/05/2005 23:20:00 4.2 0.7 6.1 2.3 4.1 0.8 6.1 2.3 3 0.8 5.3 1.5 53 12 50 255 9.8 0 10.1 9.3 06/05/2005 23:30:00 3.9 0.7 5.7 1.9 3.8 0.8 5.3 1.9 2.9 0.7 4.9 1.5 66 12 58 255 9.7 0.1 10.1 9.6 06/05/2005 23:40:00 3.9 0.7 6.1 1.9 3.8 0.7 6.1 2.3 2.8 0.8 4.9 1.1 69 13 84 255 9.6 0 9.8 9.3 06/05/2005 23:50:00 3.9 0.7 5.7 1.9 3.8 0.7 6.1 1.9 2.7 0.8 4.9 0.4 68 12 72 255 9.6 0 9.8 9.6 06/06/2005 00:00:00 3.6 0.7 5.3 1.5 3.4 0.8 4.9 1.1 2.7 0.7 4.6 0.7 69 12 61 255 9.6 0 9.8 9.6 06/06/2005 00:10:00 4.1 0.7 6.1 2.3 3.9 0.8 5.7 1.9 2.8 0.8 4.6 0.4 71 11 86 255 9.6 0 9.8 9.6 06/06/2005 00:20:00 4.4 0.7 6.5 2.3 4.3 0.8 6.5 2.6 3.1 0.9 5.3 1.1 71 13 80 255 9.5 0 9.6 9.3 06/06/2005 00:30:00 4.1 0.7 5.7 1.9 4 0.8 6.1 1.9 2.9 0.8 4.9 0.4 73 13 32 255 9.6 0 9.6 9.6 06/06/2005 00:40:00 3.9 0.6 6.1 1.9 3.8 0.7 6.1 2.3 2.7 0.7 4.2 0.4 81 13 68 255 9.2 0.1 9.6 9 06/06/2005 00:50:00 3.4 0.5 4.6 1.9 3.2 0.5 4.6 1.9 2.2 0.5 3.4 0.7 102 10 84 255 8.5 0.2 9 8.3 06/06/2005 01:00:00 3.3 0.5 4.6 1.5 3.1 0.5 4.6 1.1 2.2 0.6 3.8 0.4 111 11 102 255 8.1 0 8.5 8 06/06/2005 01:10:00 2.6 0.8 4.2 0.7 2.3 1 4.2 0.4 1.6 0.7 3.4 0.4 103 17 106 255 8 0 8.3 8 06/06/2005 01:20:00 2.1 0.3 3 1.5 1.8 0.4 3 0.7 0.8 0.4 1.9 0.4 89 13 64 255 7.8 0.2 8.3 7.3 06/06/2005 01:30:00 3 0.7 4.9 1.9 2.7 0.8 4.6 1.5 1.7 0.8 3.8 0.4 106 7 113 255 7.1 0.1 7.5 7 06/06/2005 01:40:00 4 0.6 5.3 2.3 3.9 0.6 5.3 2.3 2.8 0.6 4.2 1.1 109 12 97 255 7.6 0.2 8 7.3 06/06/2005 01:50:00 3.7 0.5 4.9 1.9 3.6 0.5 4.6 2.3 2.5 0.6 3.8 0.7 105 8 101 255 8.2 0 8.3 8 06/06/2005 02:00:00 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 2.8 0.5 4.2 1.1 101 8 107 255 8 0 8.3 7.8 06/06/2005 02:10:00 3.5 0.5 4.6 1.9 3.4 0.6 4.2 1.5 2.3 0.6 3.8 0.7 109 10 105 255 8.1 0 8.5 8 06/06/2005 02:20:00 3 0.6 4.6 1.1 2.8 0.7 4.2 0.7 1.8 0.6 3 0.4 113 13 101 255 8.4 0 8.5 8.3 06/06/2005 02:30:00 3 0.6 4.2 1.1 2.7 0.7 4.2 0.4 1.8 0.8 3.8 0.4 112 15 124 255 8.4 0 8.5 8.5 06/06/2005 02:40:00 3.3 0.7 4.9 1.5 3 0.8 4.9 0.7 2 0.8 4.2 0.4 110 14 102 255 8.5 0 8.8 8.5 06/06/2005 02:50:00 3.7 0.5 4.9 2.3 3.5 0.6 4.9 1.5 2.7 0.6 4.6 1.1 104 10 110 255 8.7 0 8.8 8.5 06/06/2005 03:00:00 3.3 0.4 4.6 2.3 3.1 0.5 4.2 1.9 2.3 0.5 3.8 1.1 110 11 102 255 8.8 0 9 8.8 06/06/2005 03:10:00 2.8 0.6 4.2 1.1 2.5 0.7 4.2 0.4 1.7 0.7 3.8 0.4 114 15 116 255 8.7 0 9 8.8 06/06/2005 03:20:00 2.8 0.8 4.6 0.7 2.5 0.8 4.6 0.4 1.5 0.8 3.8 0.4 120 17 124 255 8.7 0 8.8 8.8 06/06/2005 03:30:00 2.7 0.7 4.9 0.7 2.4 0.8 4.2 0.4 1.6 0.7 3.8 0.4 116 15 136 255 8.8 0 9 8.8 06/06/2005 03:40:00 2.7 0.6 4.2 1.1 2.5 0.7 3.8 0.7 1.5 0.6 3 0.4 112 15 86 255 8.8 0 9 8.8 06/06/2005 03:50:00 2 0.6 3.8 0.7 1.6 0.6 3.4 0.4 0.9 0.6 3 0.4 109 14 95 255 8.8 0 9 8.8 06/06/2005 04:00:00 1.5 0.7 3 0.4 1.1 0.7 3 0.4 0.6 0.4 2.3 0.4 117 19 108 255 8.7 0 8.8 8.5 06/06/2005 04:10:00 2.1 0.6 3.4 0.4 1.8 0.7 3 0.4 1.1 0.7 2.6 0.4 109 12 114 255 8.5 0 8.8 8.5 06/06/2005 04:20:00 1.8 0.5 3.4 0.7 1.5 0.5 3 0.4 0.7 0.4 1.9 0.4 112 10 106 255 8.7 0 8.8 8.5 06/06/2005 04:30:00 1.9 0.5 3 0.4 1.6 0.6 2.6 0.4 0.7 0.5 2.3 0.4 107 10 109 255 8.7 0 8.8 8.8 06/06/2005 04:40:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.6 0.4 1.5 0.4 110 9 118 255 8.7 0 8.8 8.8 06/06/2005 04:50:00 1.6 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.6 0.3 1.9 0.4 116 13 106 255 8.9 0 9 8.8 06/06/2005 05:00:00 1.5 0.4 2.6 0.4 1.1 0.4 2.3 0.4 0.6 0.3 1.5 0.4 127 8 130 255 8.9 0 9 9 06/06/2005 05:10:00 1.6 0.3 2.6 0.7 1.3 0.4 2.3 0.4 0.6 0.3 1.9 0.4 127 10 122 255 9 0 9 9 06/06/2005 05:20:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 113 17 92 255 9.1 0 9.3 9 06/06/2005 05:30:00 1.1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 105 6 95 255 9 0 9 9 06/06/2005 05:40:00 1.2 0.5 2.6 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 111 10 113 255 8.9 0 9 9 06/06/2005 05:50:00 1.4 0.4 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.5 0.4 97 6 100 255 8.9 0 9 9 06/06/2005 06:00:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 90 4 95 255 8.9 0 9 9 06/06/2005 06:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 86 255 9 0 9 9 06/06/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 255 255 9 0 9 9 06/06/2005 06:30:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 102 17 86 255 9.2 0.1 9.6 9 06/06/2005 06:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 100 15 115 255 11.1 0.6 11.7 9.6 06/06/2005 06:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 89 19 94 255 11.1 0 11.4 10.9 06/06/2005 07:00:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 25 8 15 255 11.5 0.1 11.7 11.1 06/06/2005 07:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 24 0 24 255 11.1 0 11.4 11.1 06/06/2005 07:20:00 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 21 11 19 255 11.2 0 11.4 11.1 06/06/2005 07:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 24 4 37 255 11.1 0 11.4 11.1 06/06/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 255 255 11.1 0 11.1 11.1 06/06/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 255 255 11.2 0 11.4 11.1 06/06/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 255 255 11.7 0.4 12.5 11.1 06/06/2005 08:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 32 86 255 12.9 0.2 13.5 12.5 06/06/2005 08:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 111 79 124 255 13.7 0.1 14.4 13.3 06/06/2005 08:30:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 338 33 2 255 14.2 0 14.6 13.8 06/06/2005 08:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 350 15 9 255 15.2 0.3 16.3 14.6 06/06/2005 08:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 263 107 27 255 14.8 0.2 15.5 14.6 06/06/2005 09:00:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 317 27 306 255 14.9 0 15.2 14.6 06/06/2005 09:10:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 288 32 277 255 15.5 0.2 16 15.2 06/06/2005 09:20:00 1.3 0.7 3 0.4 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 271 43 262 255 16 0.1 16.3 15.7 06/06/2005 09:30:00 1.1 0.8 3.4 0.4 0.9 0.8 3.4 0.4 0.9 0.7 3.4 0.4 281 61 249 255 16.4 0.2 16.8 16.3 06/06/2005 09:40:00 1.1 0.6 3 0.4 0.9 0.7 3 0.4 1 0.6 2.6 0.4 153 45 158 255 16.6 0.1 17.1 16.3 06/06/2005 09:50:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 260 82 211 255 17 0 17.4 16.8 06/06/2005 10:00:00 1.3 0.7 3.4 0.4 1.3 0.7 3 0.4 1.1 0.6 3 0.4 275 61 310 255 17.2 0.1 17.7 16.8 06/06/2005 10:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 302 30 257 255 17.3 0.3 18.2 16.8 06/06/2005 10:20:00 1.3 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 11 29 335 255 18 0 18.5 17.7 06/06/2005 10:30:00 1.6 0.8 4.2 0.4 1.5 0.8 3.4 0.4 1.4 0.6 3.4 0.4 303 56 240 255 18.2 0.1 18.8 18 06/06/2005 10:40:00 2 1.2 4.9 0.4 1.9 1.2 4.9 0.4 1.8 1.2 5.3 0.4 285 47 276 255 18.5 0.1 19.1 18.2 06/06/2005 10:50:00 1.8 0.8 4.6 0.4 1.8 0.8 4.2 0.4 1.5 0.9 4.2 0.4 262 66 319 255 18.3 0.2 19.1 18 06/06/2005 11:00:00 2.5 0.8 4.9 0.4 2.2 0.8 4.9 0.4 2 0.8 4.2 0.4 331 21 287 255 18.7 0.2 19.4 18.2 06/06/2005 11:10:00 2.6 0.8 4.9 0.4 2.4 0.8 4.6 0.4 2.1 1 4.6 0.4 271 51 315 255 19 0 19.4 18.8 06/06/2005 11:20:00 2.8 1.1 5.3 0.4 2.7 1.1 5.3 0.4 2.6 1.1 5.7 0.4 291 27 272 255 18.7 0.1 19.1 18.2 06/06/2005 11:30:00 2.6 1.1 4.9 0.4 2.4 1.2 5.3 0.4 2 1.2 4.6 0.4 294 23 282 255 18.7 0.1 19.1 18.2 06/06/2005 11:40:00 2.6 0.9 5.3 0.4 2.4 1 5.3 0.4 2 1 6.1 0.4 306 32 329 255 19.4 0.4 20.5 18.8 06/06/2005 11:50:00 2.8 0.7 4.9 1.1 2.7 0.7 4.9 0.7 2.5 0.7 4.6 0.7 305 32 334 255 20 0.2 20.5 19.4 06/06/2005 12:00:00 2.4 1.1 4.9 0.4 2.3 1.1 5.3 0.4 2.3 0.9 4.6 0.4 339 39 300 255 19.3 0.1 19.7 18.8 06/06/2005 12:10:00 1.9 0.9 4.2 0.4 1.7 0.9 4.2 0.4 1.6 1 4.2 0.4 330 61 311 255 20 0.2 20.5 19.4 06/06/2005 12:20:00 2.4 0.9 4.2 0.4 2.3 1 4.2 0.4 2.1 1 4.2 0.4 302 35 252 255 21.1 0.2 21.7 20.5 06/06/2005 12:30:00 2.6 0.8 4.6 0.7 2.5 0.9 4.6 0.4 2.1 1 4.9 0.4 301 29 294 255 21.4 0 22 21.1 06/06/2005 12:40:00 2.4 0.9 4.9 0.7 2.3 0.9 4.9 0.7 2.1 1 4.9 0.4 261 33 253 255 21.1 0.3 21.7 20.5 06/06/2005 12:50:00 2.8 1 6.1 0.7 2.6 1 6.1 0.4 2.3 1 5.7 0.4 294 38 293 255 21.2 0.1 21.7 20.8 06/06/2005 13:00:00 2.2 1.1 4.9 0.4 2.1 1.2 4.9 0.4 1.9 1 4.9 0.4 277 38 280 255 21.5 0.2 22 21.1 06/06/2005 13:10:00 2.9 1.1 5.3 0.4 2.8 1 5.7 0.4 2.4 1.2 5.3 0.4 295 38 314 255 21.6 0.1 22 21.1 06/06/2005 13:20:00 2.3 0.9 4.6 0.4 2.1 0.9 4.6 0.4 2 0.9 4.6 0.4 330 49 310 255 21.8 0.1 22.3 21.4 06/06/2005 13:30:00 2.9 1.2 6.5 0.4 2.8 1.3 5.7 0.4 2.3 1.3 5.3 0.4 320 35 294 255 21.6 0.7 22.6 20.3 06/06/2005 13:40:00 2.4 1 5.3 0.4 2.3 1.1 4.6 0.4 2 1 4.6 0.4 333 26 320 255 20.1 0.4 21.1 19.7 06/06/2005 13:50:00 2.9 0.8 4.6 0.7 2.7 0.8 4.6 0.7 2 0.9 5.3 0.4 332 26 343 255 20.8 0.5 21.4 20 06/06/2005 14:00:00 2.9 0.8 5.3 0.7 2.7 0.8 4.9 0.7 2.4 0.8 4.2 0.4 329 24 337 255 20.8 0.4 21.4 20 06/06/2005 14:10:00 2.5 0.7 4.6 0.7 2.3 0.7 4.2 0.7 1.9 1 4.2 0.4 323 45 296 255 22.1 0.3 22.6 21.4 06/06/2005 14:20:00 2.2 1 4.6 0.4 1.9 0.9 4.6 0.4 1.5 1 4.6 0.4 325 56 328 255 22.2 0 22.6 22 06/06/2005 14:30:00 2.7 1.1 4.9 0.4 2.4 1.1 4.9 0.4 2.3 1.2 4.9 0.4 329 38 302 255 22.2 0 22.6 21.7 06/06/2005 14:40:00 2.4 0.6 3.8 0.7 2.3 0.6 3.4 0.7 1.8 0.8 3.4 0.4 330 24 308 255 20.2 0.8 21.7 18.8 06/06/2005 14:50:00 2.3 0.4 3.4 1.5 2.1 0.4 3 1.1 1.5 0.6 3.4 0.4 324 17 345 255 18.5 0.2 19.1 18.2 06/06/2005 15:00:00 2 0.8 4.6 0.4 1.7 0.9 4.6 0.4 1.4 0.7 3 0.4 321 26 342 255 20.2 0.4 20.5 18.8 06/06/2005 15:10:00 1.9 0.9 3.4 0.4 1.7 0.9 3.4 0.4 1.4 0.8 3.4 0.4 320 11 346 255 19.5 0.3 20.5 19.1 06/06/2005 15:20:00 1.7 0.8 3.4 0.4 1.4 0.9 3.4 0.4 1.2 0.8 3 0.4 312 51 301 255 20.9 0.5 21.7 19.7 06/06/2005 15:30:00 2.4 0.9 4.6 0.4 2.2 1 4.6 0.4 1.9 0.8 4.2 0.4 0 21 8 255 22.1 0 22.9 21.7 06/06/2005 15:40:00 2.3 0.8 4.9 0.7 2.1 0.9 4.9 0.4 1.7 0.9 3.8 0.4 310 26 294 255 22.2 0 22.9 22 06/06/2005 15:50:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.8 3.8 0.4 292 32 325 255 22.3 0.2 22.9 21.7 06/06/2005 16:00:00 1.5 1 4.6 0.4 1.4 1 4.6 0.4 1.1 0.8 4.2 0.4 67 94 252 255 21.6 0 21.7 21.4 06/06/2005 16:10:00 2.9 0.8 4.9 1.1 2.9 1 4.9 0.4 2.4 1 4.9 0.4 263 22 255 255 21.5 0 21.7 21.1 06/06/2005 16:20:00 2.5 1 4.6 0.4 2.4 1 4.9 0.4 1.8 1 4.6 0.4 297 38 286 255 21.9 0 22.3 21.4 06/06/2005 16:30:00 1.6 0.9 3.8 0.4 1.4 0.9 3.8 0.4 1.2 0.7 3 0.4 335 45 358 255 22.2 0 22.6 22 06/06/2005 16:40:00 1.9 1 4.6 0.4 1.7 1 4.6 0.4 1.3 0.9 4.6 0.4 356 29 345 255 21.9 0.1 22.3 21.7 06/06/2005 16:50:00 2.1 0.9 4.9 0.4 2 0.9 4.9 0.4 1.5 0.8 3.8 0.4 311 64 313 255 21.4 0.2 22 21.1 06/06/2005 17:00:00 1.7 1 4.2 0.4 1.5 1 4.2 0.4 1.5 1.1 4.2 0.4 359 79 297 255 21 0 21.1 21.1 06/06/2005 17:10:00 2.6 1.1 5.3 0.4 2.4 1.1 5.7 0.4 1.7 1 4.6 0.4 343 51 339 255 20.9 0.1 21.1 20.5 06/06/2005 17:20:00 1.6 1 4.2 0.4 1.4 1 3.8 0.4 1.2 0.7 3.4 0.4 322 27 283 255 20.3 0 20.5 20.3 06/06/2005 17:30:00 1.9 1 4.9 0.4 1.7 1 5.3 0.4 1.6 1 3.8 0.4 39 69 85 255 19.9 0.2 20.5 19.4 06/06/2005 17:40:00 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.9 0.6 3 0.4 275 49 229 255 19.5 0 20 19.4 06/06/2005 17:50:00 2.3 1.2 4.9 0.4 2.1 1.3 4.6 0.4 1.8 1 3.8 0.4 281 90 301 255 19.4 0 20 19.1 06/06/2005 18:00:00 3.9 1.6 9.1 1.1 3.8 1.5 9.1 1.1 2.9 1.5 8.4 0.4 308 51 316 255 20.1 0 20.5 19.7 06/06/2005 18:10:00 3.2 1.7 8 0.4 3 1.7 7.6 0.4 2.7 1.5 6.8 0.4 281 39 290 255 20.3 0 20.5 20 06/06/2005 18:20:00 5 1.2 8.8 1.5 4.9 1.2 9.1 1.9 3.9 1.3 6.8 0.7 285 21 257 255 19.5 0.3 20 18.8 06/06/2005 18:30:00 4 1.2 6.5 0.7 3.9 1.2 6.8 0.4 3.1 1.3 7.2 0.4 298 18 297 255 18.6 0 18.8 18.5 06/06/2005 18:40:00 3.2 1.1 6.1 0.4 3 1.2 6.1 0.4 2.4 1.1 6.5 0.4 282 33 218 255 18.5 0 18.8 18.2 06/06/2005 18:50:00 3.7 1.4 7.6 0.7 3.5 1.5 7.6 0.4 2.8 1.4 7.2 0.4 268 26 257 255 18.4 0 18.8 18.2 06/06/2005 19:00:00 3.5 1.1 6.5 1.1 3.3 1.2 6.8 1.1 2.6 1.2 6.1 0.4 273 27 293 255 18.2 0 18.8 18 06/06/2005 19:10:00 3.4 1.2 6.5 0.4 3.3 1.2 5.7 0.4 2.3 1.1 5.3 0.4 269 28 249 255 17.8 0.1 18.2 17.4 06/06/2005 19:20:00 3 1.2 5.7 0.4 2.8 1.2 5.3 0.4 2.4 1.2 5.3 0.4 302 24 291 255 17.3 0.1 18 17.1 06/06/2005 19:30:00 2.2 0.7 3.8 0.7 1.9 0.8 3.4 0.4 1.4 0.8 3.4 0.4 319 17 345 255 16.6 0.2 17.4 16.3 06/06/2005 19:40:00 1.3 0.5 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.4 2.3 0.4 287 13 297 255 15.9 0.1 16.3 15.7 06/06/2005 19:50:00 1.4 0.6 3.4 0.4 1.1 0.7 3 0.4 0.8 0.6 2.6 0.4 264 14 260 255 15.5 0 15.7 15.2 06/06/2005 20:00:00 1.8 0.5 3 0.4 1.5 0.6 3 0.4 0.9 0.5 2.3 0.4 293 14 294 255 15 0 15.5 14.9 06/06/2005 20:10:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1 0.6 3 0.4 276 17 268 255 14.7 0 14.9 14.6 06/06/2005 20:20:00 1.7 0.6 3.4 0.4 1.4 0.7 3.4 0.4 1.1 0.6 3 0.4 266 20 258 255 14.9 0 15.5 14.6 06/06/2005 20:30:00 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 0.8 0.5 2.6 0.4 232 17 211 255 14.5 0.2 15.2 14.1 06/06/2005 20:40:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 251 45 207 255 13.8 0 14.4 13.5 06/06/2005 20:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 31 38 11 255 13.3 0.2 13.8 12.7 06/06/2005 21:00:00 1.4 0.6 2.6 0.4 1 0.7 2.6 0.4 0.6 0.4 2.3 0.4 82 30 41 255 12.7 0.2 13.3 12.5 06/06/2005 21:10:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 0.7 0.4 1.9 0.4 19 16 42 255 12.1 0.2 12.7 11.7 06/06/2005 21:20:00 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 344 4 4 255 11.7 0 12.2 11.4 06/06/2005 21:30:00 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 3 17 6 255 11.4 0.1 11.9 11.1 06/06/2005 21:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 20 0 20 255 11 0.1 11.7 10.9 06/06/2005 21:50:00 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 8 12 19 255 10.6 0 11.1 10.6 06/06/2005 22:00:00 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 0.5 0.2 1.1 0.4 17 11 10 255 10.3 0.1 10.9 10.3 06/06/2005 22:10:00 2.1 0.2 2.6 1.5 1.9 0.3 2.6 1.1 0.9 0.4 1.9 0.4 28 8 35 255 10.1 0 10.6 9.8 06/06/2005 22:20:00 2.2 0.6 3.8 1.1 2 0.6 3.8 0.7 0.9 0.6 3 0.4 22 10 9 255 9.7 0 10.1 9.6 06/06/2005 22:30:00 3.1 0.8 6.1 1.5 2.9 0.9 5.7 1.1 1.8 0.8 4.9 0.4 2 12 359 255 9.3 0.1 9.8 9 06/06/2005 22:40:00 3.1 0.7 5.3 1.5 3 0.8 4.9 1.1 1.7 0.9 3.8 0.4 6 11 15 255 9 0 9.6 9 06/06/2005 22:50:00 3.4 1 6.5 0.7 3.4 1 6.1 0.7 2.2 1 5.3 0.4 18 16 60 255 9 0 9.6 8.8 06/06/2005 23:00:00 5.1 1.2 8.4 2.6 5.1 1.2 8.4 2.3 3.9 1.3 7.2 1.1 23 13 11 255 9.6 0.6 11.1 9 06/06/2005 23:10:00 4.9 0.8 7.6 2.6 4.8 0.8 7.6 3 3.9 0.8 6.1 1.9 33 16 25 255 11.9 0.5 12.7 10.9 06/06/2005 23:20:00 3.9 1 7.2 1.9 3.8 1 6.8 1.5 3.1 0.8 5.7 1.5 49 17 41 255 13 0 13.3 12.7 06/06/2005 23:30:00 3.6 0.8 5.3 1.1 3.5 0.9 5.3 1.1 2.9 0.7 4.9 1.1 41 11 37 255 12.9 0.1 13 12.7 06/06/2005 23:40:00 4.1 0.6 5.7 2.3 4 0.6 5.7 2.3 3.3 0.8 5.3 1.1 41 9 41 255 12.7 0 12.7 12.5 06/06/2005 23:50:00 3.4 0.6 4.9 1.9 3.3 0.6 5.3 1.9 2.6 0.8 4.2 0.4 30 16 28 255 11.9 0.3 12.7 11.4 06/07/2005 00:00:00 3.6 0.7 5.3 2.3 3.6 0.8 5.7 1.5 2.7 0.7 4.2 1.1 53 13 40 255 11.7 0.2 12.2 11.4 06/07/2005 00:10:00 3.4 0.6 5.3 1.5 3.3 0.7 5.7 1.1 2.6 0.6 4.2 1.1 58 13 35 255 11.9 0 12.2 11.7 06/07/2005 00:20:00 2.9 0.6 4.6 1.1 2.8 0.7 4.6 0.7 2.2 0.7 3.8 0.7 61 13 59 255 11.3 0.2 11.7 10.9 06/07/2005 00:30:00 2.9 0.8 4.6 1.1 2.7 0.9 4.9 0.4 2 0.8 4.2 0.4 63 15 47 255 10.5 0 10.9 10.3 06/07/2005 00:40:00 3.5 1 6.1 1.5 3.4 1.1 6.1 1.1 2.5 0.9 4.6 0.7 53 15 39 255 10.9 0.1 11.1 10.6 06/07/2005 00:50:00 2.6 0.6 4.2 1.1 2.3 0.7 4.2 0.7 1.5 0.7 3.4 0.4 56 15 68 255 10.3 0.4 10.9 9.6 06/07/2005 01:00:00 2.5 0.6 4.2 1.5 2.3 0.7 4.2 0.7 1.4 0.6 3.4 0.4 74 15 65 255 8.7 0.3 9.6 8.5 06/07/2005 01:10:00 3 0.6 4.9 1.9 2.8 0.7 4.9 1.1 2.2 0.7 4.2 0.7 70 12 66 255 8.4 0 8.5 8.5 06/07/2005 01:20:00 3.5 0.7 5.7 1.9 3.4 0.8 5.7 1.5 2.3 0.8 5.3 0.7 64 13 36 255 8.9 0 9 8.5 06/07/2005 01:30:00 3.6 0.9 6.1 1.5 3.5 1 6.1 1.9 2.6 0.9 5.3 0.7 63 15 66 255 9.4 0.2 9.8 9 06/07/2005 01:40:00 3.7 0.8 5.7 1.5 3.6 0.8 5.3 1.5 2.8 0.9 4.9 0.4 48 15 42 255 10.1 0 10.6 9.6 06/07/2005 01:50:00 4.2 0.8 7.6 1.9 4.1 0.8 8 1.5 3.3 0.9 6.8 1.1 35 15 33 255 10.6 0 10.9 10.3 06/07/2005 02:00:00 5.5 1 8.8 3.4 5.4 1 8.4 3.4 4.4 1 6.8 2.3 29 13 12 255 10.6 0 10.9 10.6 06/07/2005 02:10:00 6 1.2 9.1 3.4 6 1.3 9.5 3 4.8 1.3 8.4 2.3 28 12 19 255 10.9 0 11.1 10.6 06/07/2005 02:20:00 6.4 1 9.5 3.8 6.4 1 9.9 4.2 5.3 1.1 8 1.9 30 13 10 255 11.3 0 11.7 11.1 06/07/2005 02:30:00 5.2 1 9.1 3 5.1 1.1 8.8 3 4.2 1 6.8 1.5 27 13 356 255 11.5 0 11.7 11.4 06/07/2005 02:40:00 5.4 1.2 9.5 3 5.3 1.2 10.3 3 4.4 1.4 9.9 1.5 27 12 24 255 11.2 0 11.4 11.1 06/07/2005 02:50:00 5.5 1.1 8 3 5.5 1.2 8.4 2.3 4.4 1.2 8 1.1 42 15 43 255 11.5 0 11.7 11.1 06/07/2005 03:00:00 4.3 0.9 6.5 2.3 4.3 1 6.8 1.5 3.3 0.9 5.7 1.1 47 15 44 255 11.3 0 11.7 11.1 06/07/2005 03:10:00 6.1 1 8.4 3.8 6 1 8.4 3.4 4.9 1 7.6 2.3 39 12 15 255 11.1 0 11.1 11.1 06/07/2005 03:20:00 4.2 1.2 8.8 1.9 4.1 1.3 9.1 1.9 3.3 1.2 6.8 1.1 46 17 28 255 11.1 0 11.1 10.9 06/07/2005 03:30:00 3.8 1 6.8 1.5 3.7 1.1 6.5 1.1 3.1 0.8 5.3 1.1 51 16 41 255 10.6 0 10.9 10.6 06/07/2005 03:40:00 5.1 1 7.6 2.6 5 1.1 7.2 2.3 3.8 1.1 6.8 1.5 46 16 60 255 10.6 0 10.6 10.6 06/07/2005 03:50:00 5.6 1.2 8.8 2.6 5.6 1.3 9.1 2.3 4.5 1.3 7.6 1.9 51 17 39 255 10.7 0 10.9 10.6 06/07/2005 04:00:00 5.8 1.3 9.1 1.9 5.8 1.4 9.1 2.3 4.8 1.4 8.8 2.3 45 13 44 255 10.9 0 11.1 10.6 06/07/2005 04:10:00 4.5 1 7.2 2.6 4.5 1 7.2 2.3 3.8 0.9 6.1 1.5 44 15 28 255 10.8 0 11.1 10.9 06/07/2005 04:20:00 4.6 1.4 8 1.5 4.6 1.5 8.8 1.1 3.8 1.4 7.6 1.1 59 20 53 255 10.8 0 10.9 10.9 06/07/2005 04:30:00 4.4 1.2 7.6 1.1 4.3 1.2 8 0.7 3.3 1.1 6.1 0.7 64 19 55 255 10.9 0 11.1 10.9 06/07/2005 04:40:00 4.7 1 7.2 0.7 4.7 1 6.8 1.5 3.6 1.3 6.5 0.4 67 17 49 255 11.1 0 11.1 10.9 06/07/2005 04:50:00 4.1 1 6.5 1.9 4 1 6.5 1.9 3.1 1.1 5.3 0.4 64 17 66 255 11.1 0 11.4 10.9 06/07/2005 05:00:00 3.9 1.1 6.5 1.5 3.9 1.2 6.8 1.1 3.1 1.1 6.5 0.7 56 21 43 255 10.9 0 11.1 10.9 06/07/2005 05:10:00 2.5 0.7 4.6 1.1 2.2 0.8 4.2 0.4 1.7 0.8 4.6 0.4 45 16 78 255 11.1 0.2 11.7 10.9 06/07/2005 05:20:00 2.8 0.7 4.9 1.1 2.6 0.8 4.9 0.7 2.2 0.9 4.6 0.4 57 16 64 255 11 0 11.4 10.9 06/07/2005 05:30:00 3.5 1 5.7 1.1 3.4 1.1 6.1 1.1 2.7 1.1 6.1 0.4 55 16 88 255 11.1 0 11.7 10.9 06/07/2005 05:40:00 3.7 1 6.5 1.9 3.6 1.1 6.5 1.5 2.9 1 6.1 0.4 56 17 48 255 11.9 0.1 12.5 11.4 06/07/2005 05:50:00 3.8 1.5 7.6 0.7 3.7 1.6 7.6 0.4 3 1.5 7.2 0.4 65 18 63 255 12.5 0.1 13.3 12.2 06/07/2005 06:00:00 3.6 1 6.1 1.5 3.6 1.1 6.1 1.1 3.1 1.2 5.7 0.4 68 17 66 255 12.9 0.1 13.5 12.7 06/07/2005 06:10:00 3.1 0.9 5.7 0.7 2.9 1 5.7 0.7 2.5 0.9 4.9 0.4 61 21 43 255 13.5 0.1 13.8 13 06/07/2005 06:20:00 3.4 1 6.1 0.7 3.1 1.1 6.1 0.4 2.9 1.2 6.5 0.4 56 21 38 255 13.9 0 14.6 13.8 06/07/2005 06:30:00 3.8 1.2 6.8 0.7 3.7 1.3 7.2 0.4 3 1.1 5.7 0.7 57 23 56 255 14.1 0.1 14.6 13.8 06/07/2005 06:40:00 4 1.3 8.8 1.9 3.9 1.3 8.8 1.5 3.1 1.1 7.2 0.7 59 18 55 255 14.5 0.1 15.2 14.4 06/07/2005 06:50:00 4.1 1.1 8 1.5 4.1 1.2 8 1.5 3.4 1.1 6.5 1.1 50 21 58 255 14.6 0 15.2 14.6 06/07/2005 07:00:00 3.4 1 7.6 1.5 3.3 1 7.6 1.1 2.7 0.9 5.3 0.7 54 20 78 255 15 0 15.5 14.9 06/07/2005 07:10:00 4 1.1 6.8 1.9 3.9 1.1 6.8 1.1 3.1 1.2 6.1 0.4 65 19 71 255 15.1 0 15.5 14.9 06/07/2005 07:20:00 3.9 1.1 6.8 0.7 3.8 1.2 6.8 0.4 3.3 1 6.8 1.1 61 21 50 255 15.3 0 15.7 15.2 06/07/2005 07:30:00 5.2 1.5 9.1 1.5 5.2 1.6 9.1 1.5 4.5 1.6 8.4 1.5 50 18 37 255 15.6 0 15.7 15.5 06/07/2005 07:40:00 5.7 1.2 8.4 2.6 5.7 1.2 9.1 2.3 4.7 1 7.6 2.3 45 16 28 255 15.8 0 16.3 15.5 06/07/2005 07:50:00 6.2 1.2 9.5 2.6 6.1 1.3 9.5 2.6 5 1.3 8.4 1.5 31 16 37 255 16.4 0 16.8 16 06/07/2005 08:00:00 6.4 1.2 9.5 3.4 6.4 1.2 9.1 3 5 1.2 8.8 2.3 30 19 46 255 16.8 0.1 16.8 16.6 06/07/2005 08:10:00 6.9 1.4 9.9 3.8 6.9 1.5 10.3 4.2 6 1.7 9.5 1.5 29 13 4 255 16.8 0 17.4 16.8 06/07/2005 08:20:00 6.8 1.2 10.7 3.8 6.8 1.3 10.3 3.8 5.4 1.5 9.9 2.3 26 17 14 255 17.3 0.2 17.7 16.8 06/07/2005 08:30:00 5.7 1.3 10.3 2.6 5.6 1.3 10.3 2.6 4.8 1.3 8.4 1.5 37 15 46 255 17.3 0.1 18 17.1 06/07/2005 08:40:00 7.2 1.5 10.3 3.4 7.2 1.5 10.7 2.6 5.8 1.7 9.9 1.9 24 17 16 255 17.8 0 18.2 17.7 06/07/2005 08:50:00 6.6 1.4 10.3 3.4 6.5 1.4 10.7 2.6 4.9 1.4 9.1 1.9 27 20 14 255 18.3 0.1 18.8 18 06/07/2005 09:00:00 7.2 1.2 11.5 4.2 7.2 1.2 11.1 4.6 5.4 1.3 8.8 2.3 16 13 0 255 18.4 0 18.8 18.2 06/07/2005 09:10:00 7 1.3 9.9 3 7 1.3 9.9 3 5.6 1.4 8.8 1.9 27 18 22 255 18.2 0 18.5 17.7 06/07/2005 09:20:00 6.8 1.4 11.1 3.8 6.7 1.4 10.7 2.6 5.6 1.5 9.5 2.3 36 15 42 255 18.2 0 18.8 18 06/07/2005 09:30:00 7.8 1.5 11.8 4.6 7.8 1.5 11.5 4.6 6.5 1.7 10.7 1.9 25 13 27 255 18.6 0 19.1 18.2 06/07/2005 09:40:00 4.9 1.2 8 2.3 5 1.3 8.4 1.9 4.1 1.2 8 1.1 47 21 68 255 18.9 0.1 19.4 18.5 06/07/2005 09:50:00 6.7 1.5 10.3 3.4 6.7 1.5 10.3 3.4 5.7 1.7 10.3 1.9 28 15 31 255 18.7 0.1 19.4 18.5 06/07/2005 10:00:00 6.5 1.3 10.3 3 6.5 1.3 10.7 3.4 5 1.5 9.1 0.7 24 18 4 255 18.7 0.1 19.4 18.5 06/07/2005 10:10:00 6.8 1.5 10.7 2.6 6.7 1.6 10.7 2.3 5.7 1.5 10.7 2.3 32 17 47 255 18.8 0.2 19.4 18.2 06/07/2005 10:20:00 6.3 1.5 9.9 3 6.3 1.5 9.9 3 5 1.7 9.5 1.5 30 17 42 255 18.5 0.1 19.1 18 06/07/2005 10:30:00 6.4 1.5 9.9 2.3 6.4 1.5 9.5 1.9 5.4 1.4 8.8 1.9 32 14 49 255 17.8 0 18.5 17.7 06/07/2005 10:40:00 7.8 1.7 11.1 4.6 7.7 1.7 11.1 3.8 6.3 1.9 11.5 1.5 25 17 35 255 18.4 0.4 19.4 17.7 06/07/2005 10:50:00 7.8 1.5 11.5 4.2 7.8 1.5 11.5 3.4 6.2 2 10.7 2.3 22 17 21 255 19.1 0 19.4 18.8 06/07/2005 11:00:00 8.7 1.5 12.2 4.6 8.6 1.6 12.6 4.9 6.7 1.9 10.7 2.3 21 17 20 255 18.5 0.3 19.4 17.7 06/07/2005 11:10:00 8.3 1.7 13 4.2 8.3 1.7 12.6 4.2 6.9 1.7 11.1 3 21 13 33 255 17.5 0.1 18 17.4 06/07/2005 11:20:00 8 1.7 11.5 4.6 8 1.7 11.5 4.2 6.8 1.9 10.7 1.9 26 15 27 255 17.7 0 18.2 17.4 06/07/2005 11:30:00 7.5 1.3 10.3 4.2 7.4 1.4 10.3 4.2 6.1 1.5 9.5 1.9 22 13 45 255 18 0 18.5 17.7 06/07/2005 11:40:00 7.1 1.3 11.1 3 7.1 1.3 11.1 2.6 5.7 1.4 9.1 1.9 27 17 12 255 18.7 0.1 19.4 18.2 06/07/2005 11:50:00 7 1.6 11.5 3 6.9 1.7 11.5 2.6 5.6 1.7 10.7 2.3 19 16 27 255 19 0 19.4 18.8 06/07/2005 12:00:00 7.9 1.6 12.6 4.2 7.9 1.5 11.8 4.2 6.6 1.7 10.7 2.6 29 15 32 255 18.7 0.4 19.4 18 06/07/2005 12:10:00 6.5 1.2 10.3 3.8 6.4 1.2 10.7 3.8 5.3 1.4 9.5 2.6 28 15 32 255 17.8 0 18.5 17.4 06/07/2005 12:20:00 6.7 1.2 9.9 3.8 6.6 1.2 10.3 3.8 5.3 1.5 9.1 1.5 20 15 7 255 18 0 18.5 18 06/07/2005 12:30:00 7.2 1.4 11.1 3.4 7.2 1.4 11.1 3 6 1.6 10.3 2.3 28 15 9 255 18.4 0.2 19.1 18 06/07/2005 12:40:00 7.1 1.3 10.3 4.2 7 1.3 10.3 3.4 5.9 1.3 9.5 3 27 14 34 255 19 0 19.7 18.5 06/07/2005 12:50:00 7.8 1.7 13 3.8 7.8 1.7 13.3 3.8 6.3 1.5 10.3 2.3 24 17 342 255 19.1 0 19.4 19.1 06/07/2005 13:00:00 6.5 1.5 11.1 1.9 6.4 1.6 11.5 1.5 4.4 1.5 9.9 1.9 10 17 4 255 19 0.1 19.4 18.5 06/07/2005 13:10:00 7.6 1.6 11.8 3.8 7.6 1.7 11.5 3.4 5.5 1.8 9.9 1.1 15 16 37 255 18.5 0.1 19.1 18 06/07/2005 13:20:00 7.6 1.7 12.6 3.4 7.6 1.7 12.6 3.4 5.4 1.7 9.9 1.5 13 16 16 255 18.5 0.3 19.4 18 06/07/2005 13:30:00 9.9 1.9 15.3 4.9 9.9 2 15.3 5.3 8.2 1.9 13.3 3.4 24 12 13 255 18.8 0 19.4 18.5 06/07/2005 13:40:00 8.7 1.8 13.7 3.8 8.6 1.9 13.7 3.8 7.1 1.8 11.8 1.9 26 14 21 255 19 0.3 20 18.5 06/07/2005 13:50:00 9.4 2 14.1 4.6 9.4 2 14.1 4.6 7.9 2 13 3.4 25 15 24 255 19.4 0 20 19.1 06/07/2005 14:00:00 10.3 1.9 15.3 4.9 10.3 2 15.6 4.6 8.2 2 12.6 2.6 22 16 17 255 19.1 0.1 19.7 18.8 06/07/2005 14:10:00 9.3 2 15.3 4.6 9.3 2.1 15.6 4.6 7.5 2.3 14.9 2.6 21 14 29 255 19 0.1 19.4 18.5 06/07/2005 14:20:00 10.6 1.7 15.6 6.5 10.6 1.8 15.6 5.7 8.4 1.8 13.7 4.6 23 14 13 255 18.7 0 19.1 18.5 06/07/2005 14:30:00 10 1.8 14.9 5.7 10 1.9 14.9 5.3 8.4 2.2 14.5 3 27 13 13 255 18 0.3 18.8 17.4 06/07/2005 14:40:00 8.3 1.7 13.3 4.2 8.2 1.7 13.3 4.2 6.4 1.8 12.2 2.6 14 14 17 255 17.8 0.2 18.5 17.4 06/07/2005 14:50:00 10 2.1 15.3 4.2 10 2.1 15.3 4.6 7.8 2.6 14.1 1.9 16 15 18 255 17.8 0.2 18.2 17.4 06/07/2005 15:00:00 9.4 2 15.6 4.6 9.3 2 15.6 4.9 7.4 2.4 13.7 1.5 21 17 40 255 17.3 0 17.4 17.1 06/07/2005 15:10:00 9.5 1.9 14.5 5.3 9.5 2 14.5 4.6 7.8 2 13.3 3.8 24 15 17 255 17.3 0.1 17.7 17.1 06/07/2005 15:20:00 9.4 2.1 14.5 3.8 9.3 2.2 14.5 3.4 7 2.3 11.8 2.3 14 16 27 255 17.9 0 18.2 17.7 06/07/2005 15:30:00 9.2 1.5 14.9 5.3 9.2 1.6 14.9 4.6 7.1 1.7 11.5 3.4 14 15 349 255 17.9 0.1 18.2 17.4 06/07/2005 15:40:00 8.5 1.6 12.6 3.8 8.5 1.7 12.6 3.8 6.7 1.8 11.1 2.3 7 15 7 255 16.9 0.4 17.7 16.3 06/07/2005 15:50:00 7.8 2 13.3 2.6 7.7 2.2 13 2.6 5.7 1.9 10.7 1.1 3 20 26 255 15.8 0.2 16.3 15.5 06/07/2005 16:00:00 8.8 2.5 16.8 2.6 8.8 2.6 16.8 2.6 6.5 2.6 13.3 1.5 8 17 4 255 15.2 0.1 15.7 14.9 06/07/2005 16:10:00 8.2 2.5 14.1 1.9 8.2 2.6 14.5 1.1 5.7 2.5 12.6 0.4 7 20 344 255 14.8 0.1 15.2 14.6 06/07/2005 16:20:00 8.4 2 13.3 3.4 8.4 2 13.7 3.4 5.9 2.1 11.5 1.5 8 16 12 255 14.4 0 14.9 14.1 06/07/2005 16:30:00 7.2 2.5 12.6 2.3 7.2 2.6 12.6 1.5 5.4 2.6 11.8 0.4 11 17 17 255 14.2 0 14.6 14.1 06/07/2005 16:40:00 8.5 1.6 11.8 4.2 8.5 1.6 11.8 3.8 6 2.1 11.8 1.5 6 14 12 255 14.2 0.1 14.6 14.1 06/07/2005 16:50:00 7.7 1.7 11.8 3.4 7.7 1.7 12.2 3.8 5.4 2 9.9 1.5 9 15 18 255 14.4 0 14.9 14.1 06/07/2005 17:00:00 7.7 1.4 11.5 4.2 7.7 1.3 11.5 4.6 5.8 1.5 9.9 1.9 11 14 306 255 14.6 0 15.2 14.4 06/07/2005 17:10:00 8.5 1.5 12.2 3 8.5 1.5 11.8 3.4 6.6 1.7 11.8 2.3 14 12 11 255 14.6 0 15.2 14.6 06/07/2005 17:20:00 8.4 2.2 13.3 3.8 8.4 2.2 13.7 3.4 6.4 2.3 12.6 1.5 13 16 12 255 14.7 0.2 15.2 14.6 06/07/2005 17:30:00 8.4 1.7 12.2 4.2 8.4 1.8 13 3.8 6.3 2.2 11.1 1.5 13 15 25 255 14.7 0.1 15.2 14.6 06/07/2005 17:40:00 9.9 2 15.6 5.3 10 2 15.6 4.9 7.2 2.2 13.3 2.6 9 13 21 255 14.6 0.1 15.2 14.6 06/07/2005 17:50:00 10.6 2.1 16.1 6.1 10.6 2.1 16.1 6.1 8.3 2.3 14.5 3 14 13 11 255 14.6 0.1 15.2 14.6 06/07/2005 18:00:00 9.9 1.9 14.9 3.8 9.9 2 14.5 3.4 7.7 2.4 13.7 1.9 14 14 30 255 14.6 0.1 15.2 14.6 06/07/2005 18:10:00 10.1 1.7 14.1 4.6 10.1 1.7 14.1 4.9 7.3 2.1 13 2.6 11 15 4 255 14.6 0 15.2 14.6 06/07/2005 18:20:00 8.7 1.5 13.3 5.3 8.7 1.6 13.3 5.3 6.4 1.9 11.8 3 9 14 3 255 14.5 0 14.9 14.4 06/07/2005 18:30:00 8.8 1.8 13.7 4.2 8.8 1.9 14.1 3.8 6.5 1.7 12.2 2.6 13 13 9 255 14.5 0 14.9 14.4 06/07/2005 18:40:00 9 2.3 16.1 3.4 9 2.4 16.4 3 6.4 2.5 14.5 1.9 13 13 26 255 14.3 0.1 14.9 14.4 06/07/2005 18:50:00 9.6 1.7 13 4.6 9.5 1.7 13.3 4.6 7.2 2.2 12.6 2.6 14 15 22 255 14.3 0 14.9 14.4 06/07/2005 19:00:00 8.1 1.7 13.3 3.8 8.1 1.7 13 3.8 5.9 2 12.2 1.1 9 15 11 255 14.2 0.1 14.6 14.1 06/07/2005 19:10:00 9.4 1.7 14.5 4.9 9.4 1.7 14.1 4.2 6.9 2.1 13 2.3 9 13 9 255 14.1 0.1 14.6 13.8 06/07/2005 19:20:00 7.6 1.9 12.6 2.6 7.5 2 13.3 2.3 5.2 1.7 11.1 1.1 8 13 328 255 14.1 0.2 14.6 13.8 06/07/2005 19:30:00 7.2 1.8 12.6 2.3 7.2 1.8 12.2 2.3 5.4 1.7 10.3 1.9 17 19 4 255 13.9 0 14.6 13.8 06/07/2005 19:40:00 10 1.9 14.1 4.6 10 2 14.9 4.6 7.5 2.3 13.3 3 11 14 1 255 13.9 0 14.4 13.8 06/07/2005 19:50:00 9.8 1.7 14.1 5.7 9.8 1.7 14.1 5.3 8 2 13 3.4 20 12 17 255 13.9 0 14.4 13.8 06/07/2005 20:00:00 9.2 1.7 13.7 5.3 9.2 1.7 13.7 5.7 7.4 2 13.3 3 18 11 30 255 13.8 0 14.4 13.8 06/07/2005 20:10:00 10.1 1.7 14.5 5.3 10.1 1.7 14.5 5.3 7.9 1.9 13.3 2.6 15 11 16 255 13.8 0 13.8 13.8 06/07/2005 20:20:00 8.5 1.4 11.8 4.6 8.5 1.3 11.8 5.3 6.7 1.5 10.3 3.4 18 11 14 255 13.9 0 14.4 13.8 06/07/2005 20:30:00 7.7 1.7 12.2 3.8 7.8 1.7 12.6 3.8 5.6 1.7 9.5 1.5 13 14 2 255 13.7 0 14.4 13.5 06/07/2005 20:40:00 9.2 2.2 14.1 4.6 9.2 2.2 14.1 4.2 6.8 2.4 12.6 1.5 12 13 17 255 13.8 0 14.4 13.5 06/07/2005 20:50:00 8.3 1.9 14.1 4.2 8.3 2 14.5 3.8 6.2 2.2 13.3 1.9 13 13 4 255 13.8 0 14.4 13.5 06/07/2005 21:00:00 6 1.5 11.8 2.6 6 1.6 11.8 2.3 4.4 1.5 9.1 1.1 7 13 11 255 13.5 0 14.1 13.3 06/07/2005 21:10:00 7.1 1.5 11.1 3.8 7 1.5 11.1 3.8 5.4 1.7 9.5 1.9 14 14 19 255 13.4 0 13.8 13.3 06/07/2005 21:20:00 7.7 1.3 10.7 4.2 7.7 1.3 10.7 4.2 5.9 1.6 10.7 2.3 15 12 31 255 13.5 0.1 13.8 13.3 06/07/2005 21:30:00 8 1.5 11.8 3.8 7.9 1.5 11.5 3.4 5.9 1.7 10.7 1.5 11 12 6 255 13.6 0 14.1 13.5 06/07/2005 21:40:00 8.3 1.8 13.3 3.4 8.3 1.9 13.3 3 5.7 2 11.1 1.1 2 18 16 255 13.7 0 13.8 13.5 06/07/2005 21:50:00 6.6 1.6 12.6 3 6.5 1.7 12.6 3.4 4.4 1.6 9.1 1.1 356 15 9 255 13.5 0 13.8 13.3 06/07/2005 22:00:00 4.9 1.2 8.8 2.3 4.7 1.2 8.4 2.3 3.5 1.3 7.2 0.4 348 15 332 255 13.3 0 13.8 13 06/07/2005 22:10:00 5.4 1.1 8.8 1.9 5.1 1.2 8.4 1.9 3.8 1.3 7.2 1.1 342 22 339 255 13 0 13.5 12.7 06/07/2005 22:20:00 5.1 1.5 10.3 1.5 4.9 1.5 9.5 1.1 3.6 1.5 8.8 1.1 341 20 329 255 13.1 0 13.5 12.7 06/07/2005 22:30:00 3.4 0.7 5.7 1.9 3.2 0.8 5.3 1.5 2.6 0.8 4.6 0.7 322 21 309 255 12.7 0 13 12.5 06/07/2005 22:40:00 3.6 0.7 5.3 1.5 3.4 0.8 5.7 1.5 2.6 0.9 5.3 0.7 337 20 324 255 12.3 0 12.7 12.2 06/07/2005 22:50:00 3.2 0.8 6.5 1.5 3.1 0.8 6.5 1.5 2.5 1 5.7 0.7 316 15 323 255 12.2 0 12.5 11.9 06/07/2005 23:00:00 3.2 0.8 5.7 0.7 3.1 0.8 5.7 1.1 2.5 0.9 4.9 0.4 306 19 316 255 12 0 12.5 11.9 06/07/2005 23:10:00 2.2 0.6 4.6 0.7 2 0.7 3.8 0.4 1.2 0.6 2.6 0.4 322 28 343 255 11.7 0 12.2 11.4 06/07/2005 23:20:00 1.6 0.6 3 0.4 1.2 0.6 3 0.4 0.8 0.5 2.3 0.4 327 22 298 255 11.3 0 11.9 11.1 06/07/2005 23:30:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 318 23 340 255 11 0 11.4 10.9 06/07/2005 23:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 214 90 310 255 10.7 0 11.4 10.6 06/07/2005 23:50:00 1.7 0.6 2.6 0.4 1.5 0.7 2.6 0.4 1.6 0.5 2.6 0.4 147 13 136 255 10.5 0 10.6 10.3 06/08/2005 00:00:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1.4 0.6 2.3 0.4 130 10 129 255 10.5 0 10.9 10.3 06/08/2005 00:10:00 1.3 0.6 2.6 0.4 1.1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 130 27 144 255 10.4 0.1 10.6 10.3 06/08/2005 00:20:00 1.8 1 3.8 0.4 1.6 1 3.8 0.4 1.3 0.7 3 0.4 114 26 112 255 10.3 0 10.6 10.3 06/08/2005 00:30:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 0.4 2.1 0.6 3.4 0.4 105 9 101 255 10.7 0.1 11.1 10.6 06/08/2005 00:40:00 3.5 0.5 4.6 2.3 3.5 0.5 4.6 1.9 2.6 0.6 3.8 0.7 96 8 100 255 11 0 11.1 10.9 06/08/2005 00:50:00 3 0.5 4.6 1.9 3 0.5 4.6 1.5 2 0.5 3.4 0.7 94 7 84 255 11.1 0 11.1 11.1 06/08/2005 01:00:00 3.1 0.5 4.2 1.5 3 0.5 4.2 1.5 2.2 0.5 3.4 1.1 97 7 100 255 11.1 0 11.1 10.9 06/08/2005 01:10:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 1.9 0.5 3.4 0.4 101 8 74 255 11.1 0 11.1 11.1 06/08/2005 01:20:00 3 0.6 4.2 1.5 2.9 0.6 3.8 1.1 2 0.6 3.4 0.7 106 10 94 255 10.9 0 11.1 10.9 06/08/2005 01:30:00 3.2 0.5 4.2 1.9 3.2 0.4 4.2 1.5 2.3 0.5 3.4 0.4 104 9 102 255 10.9 0.1 11.1 10.6 06/08/2005 01:40:00 2.1 0.8 3.8 0.4 2 0.8 3.8 0.4 1.3 0.6 3 0.4 108 13 132 255 10.7 0 10.9 10.6 06/08/2005 01:50:00 0.7 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.4 0.2 1.1 0.4 47 36 95 255 10.5 0 10.9 10.3 06/08/2005 02:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 29 28 0 255 10 0 10.3 9.8 06/08/2005 02:10:00 1.2 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.4 1.9 0.4 303 15 302 255 9.6 0 9.8 9.6 06/08/2005 02:20:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 256 11 244 255 9.4 0 9.6 9.3 06/08/2005 02:30:00 0.9 0.3 1.5 0.4 0.7 0.2 1.1 0.4 0.7 0.3 1.5 0.4 186 29 236 255 9.2 0 9.6 9 06/08/2005 02:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 196 9 157 255 9.1 0 9.3 9 06/08/2005 02:50:00 1.1 0.8 3 0.4 1 0.7 3 0.4 0.8 0.6 2.6 0.4 256 41 306 255 9 0 9 8.8 06/08/2005 03:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 260 9 252 255 8.7 0 9 8.5 06/08/2005 03:10:00 1.7 0.7 3 0.4 1.5 0.8 2.6 0.4 1 0.6 2.3 0.4 259 8 258 255 8.6 0 8.8 8.5 06/08/2005 03:20:00 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.7 0.4 1.5 0.4 244 15 237 255 8.4 0 8.8 8.5 06/08/2005 03:30:00 1.8 0.3 2.6 1.1 1.7 0.3 2.3 0.7 0.9 0.4 1.9 0.4 227 11 212 255 8.5 0 8.5 8.5 06/08/2005 03:40:00 1.6 0.3 2.3 0.7 1.4 0.3 1.9 0.7 0.8 0.3 1.9 0.4 198 3 202 255 8.5 0 8.8 8.5 06/08/2005 03:50:00 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 184 9 151 255 8.4 0 8.5 8.5 06/08/2005 04:00:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 124 20 141 255 8.4 0 8.5 8.3 06/08/2005 04:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 35 107 255 8.3 0 8.5 8.3 06/08/2005 04:20:00 1.1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.4 1.9 0.4 68 23 81 255 8.3 0 8.5 8.3 06/08/2005 04:30:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 89 6 100 255 8.3 0 8.5 8.3 06/08/2005 04:40:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 51 35 91 255 8.3 0 8.5 8.3 06/08/2005 04:50:00 1.2 0.5 2.6 0.4 0.9 0.4 1.9 0.4 0.6 0.5 2.3 0.4 37 36 336 255 8.3 0 8.5 8.3 06/08/2005 05:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 33 23 20 255 8.3 0 8.5 8.3 06/08/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 255 255 8.2 0 8.3 8.3 06/08/2005 05:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 66 255 8.3 0 8.5 8.3 06/08/2005 05:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 123 10 126 255 8.3 0 8.5 8.3 06/08/2005 05:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 15 23 255 8.4 0 8.5 8.5 06/08/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 23 255 8.5 0 8.5 8.5 06/08/2005 06:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 43 30 89 255 8.6 0 8.8 8.5 06/08/2005 06:10:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 72 9 80 255 8.7 0 9 8.5 06/08/2005 06:20:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 10 33 337 255 8.9 0 9 8.8 06/08/2005 06:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 25 18 20 255 9.1 0 9.3 9 06/08/2005 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 18 112 255 9.3 0 9.6 9.3 06/08/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 112 0 112 255 9.6 0 9.6 9.3 06/08/2005 07:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 82 43 112 255 9.7 0 9.8 9.6 06/08/2005 07:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 10 9 356 255 9.8 0 9.8 9.6 06/08/2005 07:20:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 55 35 12 255 9.9 0 10.1 9.8 06/08/2005 07:30:00 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 102 9 105 255 10 0 10.1 9.8 06/08/2005 07:40:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 81 5 91 255 10 0 10.1 9.8 06/08/2005 07:50:00 1.6 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.8 0.4 1.9 0.4 92 15 100 255 10 0 10.1 9.8 06/08/2005 08:00:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 82 22 90 255 10 0 10.1 9.8 06/08/2005 08:10:00 1.5 0.3 2.6 0.7 1.3 0.4 2.6 0.4 0.9 0.3 1.5 0.4 85 13 84 255 10 0 10.1 9.8 06/08/2005 08:20:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0 24 31 255 10 0 10.1 9.8 06/08/2005 08:30:00 0.7 0.5 2.6 0.4 0.6 0.5 2.3 0.4 0.6 0.3 1.5 0.4 57 51 58 255 10.2 0 10.3 10.1 06/08/2005 08:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 350 47 351 255 10.5 0 10.6 10.3 06/08/2005 08:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 312 79 314 255 10.6 0 10.6 10.6 06/08/2005 09:00:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 144 17 136 255 10.6 0 10.6 10.6 06/08/2005 09:10:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 198 53 289 255 10.7 0 10.9 10.6 06/08/2005 09:20:00 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.5 1.9 0.4 222 82 303 255 10.9 0 11.1 10.9 06/08/2005 09:30:00 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 0.8 0.5 2.3 0.4 100 10 93 255 11.1 0.1 11.4 10.9 06/08/2005 09:40:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 0.7 1.8 0.8 4.2 0.4 95 13 113 255 11.5 0 11.7 11.1 06/08/2005 09:50:00 3.7 0.6 5.3 1.9 3.7 0.6 5.3 1.9 3 0.7 4.6 1.1 97 12 93 255 12 0 12.2 11.7 06/08/2005 10:00:00 3.5 0.6 4.9 2.3 3.3 0.6 4.9 1.5 2.6 0.7 4.2 0.7 84 17 110 255 12.5 0.1 12.7 12.2 06/08/2005 10:10:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.5 2.3 0.7 3.8 0.4 85 12 89 255 12.9 0 13 12.7 06/08/2005 10:20:00 3.4 0.6 4.9 1.5 3.3 0.7 4.9 1.9 2.4 0.7 4.2 1.1 86 12 85 255 12.9 0 13 12.7 06/08/2005 10:30:00 3.7 0.6 5.3 2.3 3.7 0.6 4.9 1.9 2.9 0.7 4.9 1.1 84 9 80 255 12.9 0 13 12.7 06/08/2005 10:40:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 2.3 2.7 0.6 4.2 1.1 84 12 82 255 13 0 13 13 06/08/2005 10:50:00 3.6 0.6 5.3 2.3 3.6 0.7 5.3 1.9 2.6 0.6 4.2 1.1 89 12 81 255 13.1 0 13.5 13 06/08/2005 11:00:00 3.3 0.5 4.6 1.5 3.3 0.5 4.2 1.5 2.6 0.5 3.8 1.1 79 10 95 255 13.3 0 13.8 13 06/08/2005 11:10:00 3.7 0.6 4.9 2.3 3.6 0.6 4.9 1.9 2.7 0.7 4.6 0.7 84 12 80 255 13.3 0 13.8 13.3 06/08/2005 11:20:00 3.2 0.6 4.6 1.5 3.2 0.6 4.6 1.5 2.3 0.7 3.8 0.7 78 11 84 255 13.5 0 14.1 13.3 06/08/2005 11:30:00 3.1 0.5 4.9 1.9 3.1 0.5 4.9 1.9 2.2 0.5 3.4 0.7 83 10 74 255 13.6 0 14.4 13.5 06/08/2005 11:40:00 3.1 0.9 4.9 0.7 3.1 1 4.9 0.4 2.4 0.8 4.2 0.4 83 23 77 255 13.7 0 14.4 13.5 06/08/2005 11:50:00 2.5 0.7 4.2 0.7 2.5 0.8 3.8 0.7 1.9 0.7 3.8 0.4 66 17 73 255 14.2 0.1 14.9 13.8 06/08/2005 12:00:00 2.3 0.9 4.2 0.4 2.2 0.9 4.2 0.4 1.8 0.9 4.2 0.4 77 17 61 255 14.8 0 15.5 14.6 06/08/2005 12:10:00 2.1 0.5 3.4 0.7 2 0.5 3.4 0.4 1.6 0.6 3 0.4 88 18 105 255 15 0 15.5 14.9 06/08/2005 12:20:00 2.3 1 4.2 0.4 2.2 1 3.8 0.4 1.9 0.9 3.8 0.4 96 29 129 255 15 0 15.5 15.2 06/08/2005 12:30:00 2.2 0.5 3.8 1.1 2.1 0.5 3.4 0.7 1.9 0.5 3.8 0.7 68 22 62 255 15 0 15.7 15.2 06/08/2005 12:40:00 2.3 0.4 3.4 0.7 2.1 0.5 3.4 0.7 1.8 0.6 3.4 0.4 97 12 90 255 15.1 0 15.7 15.2 06/08/2005 12:50:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.5 2.3 0.4 89 17 108 255 15.4 0 15.7 15.2 06/08/2005 13:00:00 2.1 0.6 4.2 0.4 2 0.6 3.8 0.4 1.7 0.6 4.2 0.4 102 32 122 255 15.5 0 16 15.5 06/08/2005 13:10:00 2.6 0.8 4.2 0.7 2.5 0.8 4.6 0.4 2.3 0.8 4.9 0.7 117 21 128 255 15.7 0.1 16.3 15.7 06/08/2005 13:20:00 2.7 0.6 4.6 1.1 2.7 0.6 4.2 1.1 2.3 0.7 3.8 0.7 97 20 92 255 16.1 0.1 16.8 15.7 06/08/2005 13:30:00 2.6 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2.3 0.7 3.8 0.4 108 17 80 255 16.5 0 16.8 16.3 06/08/2005 13:40:00 2.3 0.7 4.2 0.7 2.2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 116 24 118 255 16.6 0 17.1 16.3 06/08/2005 13:50:00 2.5 0.6 3.8 0.7 2.5 0.6 4.2 1.1 2.1 0.7 3.8 0.4 113 15 122 255 16.7 0 17.1 16.6 06/08/2005 14:00:00 2.9 0.5 4.2 1.9 2.9 0.5 4.2 1.9 2.4 0.7 4.2 0.4 86 16 82 255 16.8 0 17.1 16.6 06/08/2005 14:10:00 3.4 0.6 5.3 1.5 3.4 0.6 5.3 1.5 2.7 0.6 4.2 1.1 84 13 95 255 16.8 0 17.1 16.8 06/08/2005 14:20:00 2.2 0.8 4.2 0.4 2.1 0.8 3.8 0.4 1.8 1 3.8 0.4 16 49 287 255 16.9 0 17.4 16.8 06/08/2005 14:30:00 2.4 0.6 4.2 0.7 2.4 0.6 3.8 0.7 2 0.6 4.2 0.4 267 26 297 255 16.8 0 17.1 16.6 06/08/2005 14:40:00 2.4 1.2 5.3 0.4 2.3 1.3 5.3 0.4 2 1.1 4.9 0.4 252 45 307 255 16.4 0.1 17.1 16.3 06/08/2005 14:50:00 2.5 0.7 3.8 1.1 2.4 0.7 4.2 0.4 2 0.8 4.2 0.4 260 14 255 255 16.4 0.2 17.1 16.3 06/08/2005 15:00:00 2 0.7 3.8 0.4 1.9 0.7 3.4 0.4 1.5 0.8 3.4 0.4 265 24 247 255 16.2 0.1 16.8 16.3 06/08/2005 15:10:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.3 0.7 3 0.4 262 45 253 255 15.9 0 16.6 15.7 06/08/2005 15:20:00 1.8 0.8 3 0.4 1.7 0.9 3 0.4 1.6 0.8 3 0.4 290 21 241 255 16.1 0 16.6 16 06/08/2005 15:30:00 2.8 0.7 4.2 0.4 2.7 0.8 4.2 0.4 2.3 0.8 4.2 0.4 299 20 281 255 16.1 0 16.8 16 06/08/2005 15:40:00 2.7 0.8 4.6 0.7 2.6 0.9 4.6 0.4 2.2 0.8 4.2 0.4 301 20 303 255 16 0 16.6 15.7 06/08/2005 15:50:00 3.2 0.6 4.6 1.1 3 0.6 4.6 0.7 2.7 0.7 4.6 1.1 290 18 298 255 15.5 0.1 16.3 15.2 06/08/2005 16:00:00 2.2 0.8 4.2 0.7 2.1 0.8 3.8 0.4 1.8 0.9 3.8 0.4 290 14 290 255 15.2 0.1 15.7 15.2 06/08/2005 16:10:00 2.3 0.8 4.6 0.4 2.2 0.9 4.6 0.4 1.7 0.9 4.2 0.4 289 24 300 255 15.5 0 16 15.5 06/08/2005 16:20:00 2.6 0.8 4.6 0.4 2.5 0.8 4.2 0.4 2.1 0.9 4.2 0.4 296 14 288 255 15.4 0 15.7 15.2 06/08/2005 16:30:00 2.7 0.6 4.6 1.1 2.7 0.6 4.6 1.1 2.1 0.7 4.6 0.7 289 17 289 255 15 0 15.5 14.9 06/08/2005 16:40:00 2.7 0.9 4.9 0.4 2.5 1 4.6 0.4 1.9 0.9 4.6 0.4 303 24 295 255 15.2 0 15.5 15.2 06/08/2005 16:50:00 2.6 0.8 4.2 0.4 2.5 0.9 4.2 0.4 2 1 4.2 0.4 274 22 307 255 15 0 15.5 14.9 06/08/2005 17:00:00 2.6 0.8 4.6 0.4 2.6 0.9 4.9 0.4 2.2 0.7 4.2 0.4 267 17 274 255 14.8 0 15.2 14.6 06/08/2005 17:10:00 1.8 1.1 4.6 0.4 1.7 1.1 4.6 0.4 1.2 0.9 3.4 0.4 259 24 159 255 14.6 0.1 15.2 14.6 06/08/2005 17:20:00 2.5 0.4 3.4 1.1 2.4 0.5 3.4 1.1 1.8 0.6 3 0.4 248 15 261 255 14.7 0 15.2 14.6 06/08/2005 17:30:00 1.7 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.9 3.4 0.4 260 18 251 255 14.6 0.1 15.2 14.6 06/08/2005 17:40:00 0.8 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 163 86 235 255 14.6 0 15.2 14.6 06/08/2005 17:50:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.4 1.3 0.5 2.6 0.4 262 27 233 255 14.6 0 15.2 14.6 06/08/2005 18:00:00 1.5 0.5 3 0.4 1.4 0.6 3 0.4 1.2 0.5 2.3 0.4 239 16 216 255 14.5 0 15.2 14.4 06/08/2005 18:10:00 2.3 0.7 4.2 1.1 2.3 0.8 4.2 0.4 1.6 0.8 3.4 0.4 276 21 274 255 14.3 0.1 14.9 14.1 06/08/2005 18:20:00 1.7 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.2 0.6 3 0.4 268 27 293 255 14.1 0.1 14.6 13.8 06/08/2005 18:30:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.5 0.8 3.8 0.4 276 21 255 255 13.9 0 14.6 13.8 06/08/2005 18:40:00 1.9 0.7 3.4 0.4 1.7 0.8 3 0.4 1.3 0.7 3 0.4 285 22 303 255 13.8 0 13.8 13.5 06/08/2005 18:50:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 285 12 293 255 13.7 0 13.8 13.5 06/08/2005 19:00:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.8 0.5 1.9 0.4 308 14 286 255 13.5 0 13.8 13.3 06/08/2005 19:10:00 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.9 0.4 300 10 290 255 13.4 0 13.8 13.3 06/08/2005 19:20:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 11 24 13 255 13.5 0 13.8 13.3 06/08/2005 19:30:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.5 0.4 1.9 0.4 358 22 14 255 13.7 0 14.1 13.5 06/08/2005 19:40:00 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.1 0.5 2.3 0.4 317 56 14 255 13.6 0 14.4 13.3 06/08/2005 19:50:00 0.9 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.6 0.4 1.9 0.4 259 47 252 255 13.5 0.1 13.8 13.3 06/08/2005 20:00:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 176 33 163 255 13.4 0 13.8 13.3 06/08/2005 20:10:00 1.5 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 164 21 160 255 13.3 0 13.5 13 06/08/2005 20:20:00 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 169 30 194 255 13.3 0 13.5 13.3 06/08/2005 20:30:00 2.2 0.6 3.8 1.1 2.1 0.6 4.2 0.7 1.8 0.6 3.4 0.7 88 24 60 255 13.4 0 13.8 13.3 06/08/2005 20:40:00 4 0.8 6.5 1.9 3.9 0.8 6.5 1.9 3 0.9 5.7 1.1 32 15 25 255 13.6 0 13.8 13.3 06/08/2005 20:50:00 2.6 0.8 4.6 0.4 2.5 0.9 4.6 0.4 1.6 0.9 3.4 0.4 359 22 8 255 13.7 0 14.4 13.5 06/08/2005 21:00:00 2.7 1 6.5 0.4 2.5 1 5.7 0.4 1.6 0.8 4.2 0.4 359 26 352 255 13.4 0 13.8 13.3 06/08/2005 21:10:00 2.7 0.6 4.2 1.1 2.7 0.7 4.2 1.1 1.7 0.7 3.8 0.4 17 13 2 255 13.2 0 13.8 13 06/08/2005 21:20:00 2.5 1 4.6 0.4 2.5 1 4.6 0.4 1.7 1 4.2 0.4 5 23 24 255 12.9 0 13.3 12.7 06/08/2005 21:30:00 1.8 0.7 4.2 0.4 1.5 0.7 4.2 0.4 0.9 0.6 3 0.4 342 17 349 255 12.5 0 12.7 12.2 06/08/2005 21:40:00 2.1 0.6 4.2 0.4 2 0.6 3.8 0.4 1.4 0.7 3 0.4 26 21 20 255 12.2 0 12.5 11.9 06/08/2005 21:50:00 3.8 1.1 6.5 1.5 3.8 1.1 6.5 1.5 3 1.2 5.7 0.4 25 15 3 255 12 0.1 12.5 11.7 06/08/2005 22:00:00 3 0.6 4.6 1.5 2.9 0.7 4.9 1.1 2.4 0.8 4.2 0.4 64 28 38 255 12.7 0 12.7 12.5 06/08/2005 22:10:00 2.2 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.7 0.9 4.6 0.4 88 29 108 255 12.7 0 12.7 12.5 06/08/2005 22:20:00 3.1 0.8 4.9 0.4 3.2 0.8 5.3 0.4 2.5 0.8 4.6 0.4 69 17 51 255 12.4 0 12.7 12.2 06/08/2005 22:30:00 3.5 0.8 5.7 1.1 3.5 0.9 5.7 1.5 2.8 0.8 4.9 0.7 57 15 61 255 12.3 0 12.5 12.2 06/08/2005 22:40:00 3 0.7 4.9 1.5 3 0.8 4.9 1.5 2.3 0.7 4.2 0.4 59 12 60 255 12.3 0 12.5 12.2 06/08/2005 22:50:00 2.8 0.5 4.9 1.5 2.8 0.6 5.3 1.5 2 0.6 3.4 0.4 37 15 37 255 12.1 0 12.2 11.9 06/08/2005 23:00:00 3.5 0.7 5.7 1.9 3.5 0.7 5.3 1.9 2.7 0.7 4.6 1.5 38 12 37 255 12.1 0 12.2 11.9 06/08/2005 23:10:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.8 0.6 3.4 0.4 56 15 52 255 11.9 0.1 12.2 11.7 06/08/2005 23:20:00 2.8 0.5 3.8 1.5 2.8 0.5 4.2 1.1 1.9 0.6 3.4 0.4 66 16 77 255 11.7 0 11.9 11.4 06/08/2005 23:30:00 3.3 0.6 4.9 1.5 3.2 0.6 5.3 1.1 2.3 0.7 4.2 0.4 58 17 26 255 11.4 0 11.7 11.4 06/08/2005 23:40:00 3.2 0.5 4.6 1.5 3.2 0.6 4.6 1.5 2.4 0.6 3.8 0.7 60 12 56 255 11.7 0 11.7 11.7 06/08/2005 23:50:00 3.8 0.6 5.3 2.3 3.7 0.6 5.3 2.6 2.8 0.7 4.9 1.5 23 13 25 255 11.5 0.1 11.7 11.1 06/09/2005 00:00:00 4 0.7 6.1 2.3 3.9 0.7 6.1 2.3 2.9 0.8 4.9 1.1 27 15 22 255 11.1 0 11.4 11.1 06/09/2005 00:10:00 2.2 0.5 3.4 0.7 2.1 0.5 3.4 0.7 1.7 0.6 3 0.4 58 10 41 255 11.3 0 11.4 11.1 06/09/2005 00:20:00 2.2 0.5 3.8 0.7 2.2 0.5 3.8 0.7 1.5 0.6 3 0.4 65 12 76 255 10.9 0.1 11.1 10.9 06/09/2005 00:30:00 3.5 0.7 4.9 1.5 3.5 0.7 4.9 1.5 2.4 0.7 4.2 0.7 79 9 76 255 10.6 0 10.9 10.6 06/09/2005 00:40:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.3 2.8 0.6 4.2 1.1 76 10 92 255 10.5 0 10.6 10.3 06/09/2005 00:50:00 3.6 0.8 6.1 1.9 3.5 0.9 5.7 1.5 2.7 1 5.3 0.7 80 17 80 255 10.7 0 10.9 10.6 06/09/2005 01:00:00 3.5 0.7 5.3 1.9 3.5 0.7 5.7 1.5 2.6 0.8 5.3 0.4 87 12 87 255 11 0 11.1 10.9 06/09/2005 01:10:00 3 0.7 4.9 0.7 3 0.7 4.6 1.1 2.1 0.7 3.8 0.7 85 12 84 255 11.1 0 11.1 11.1 06/09/2005 01:20:00 3.3 0.6 4.6 1.5 3.2 0.6 4.6 1.5 2.2 0.6 3.8 0.7 81 12 97 255 10.9 0 11.1 10.9 06/09/2005 01:30:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 1.9 2.5 0.5 4.2 1.5 71 9 83 255 10.9 0 11.1 10.9 06/09/2005 01:40:00 3 0.6 4.6 0.7 3 0.7 4.6 1.1 2 0.8 3.4 0.4 58 13 56 255 10.7 0 10.9 10.6 06/09/2005 01:50:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2 0.4 2.6 0.7 78 11 90 255 10.5 0.1 10.9 10.3 06/09/2005 02:00:00 2.3 0.3 3.4 1.5 2.3 0.3 3.4 1.5 1.6 0.3 2.6 0.7 85 6 74 255 10 0 10.3 9.8 06/09/2005 02:10:00 2.9 0.5 4.2 1.1 2.8 0.5 4.2 1.1 2.2 0.5 3.4 0.7 88 16 81 255 9.6 0 9.8 9.3 06/09/2005 02:20:00 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.9 2 0.5 3 0.4 104 8 98 255 9.4 0 9.6 9.3 06/09/2005 02:30:00 2.5 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.7 0.5 2.6 0.4 105 10 97 255 9.1 0 9.6 9 06/09/2005 02:40:00 2.4 0.4 3 1.1 2.4 0.4 3 1.1 1.6 0.5 3 0.4 105 13 101 255 8.8 0 9 8.5 06/09/2005 02:50:00 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.1 1.9 0.5 3 0.7 98 10 93 255 8.5 0 8.8 8.5 06/09/2005 03:00:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.7 1.3 0.6 2.3 0.4 91 8 79 255 8.7 0 8.8 8.5 06/09/2005 03:10:00 2.4 0.5 3.8 1.1 2.3 0.5 3.4 1.1 1.1 0.5 2.3 0.4 94 5 84 255 8.4 0 8.8 8.3 06/09/2005 03:20:00 2.9 0.3 3.4 1.5 2.9 0.3 3.4 2.3 2 0.5 3 0.7 99 8 99 255 8.3 0 8.5 8.3 06/09/2005 03:30:00 3.1 0.4 3.8 1.9 3 0.4 4.2 1.9 2.2 0.6 3.8 1.1 105 10 100 255 8.6 0 9 8.5 06/09/2005 03:40:00 3.1 0.5 4.2 1.5 3 0.5 4.2 1.5 2.1 0.6 3.8 0.4 108 15 79 255 9 0.1 9.3 8.8 06/09/2005 03:50:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 2.3 0.7 3.8 1.1 104 11 105 255 9.4 0.1 9.6 9 06/09/2005 04:00:00 3.3 0.6 4.9 1.9 3.3 0.6 4.6 1.5 2.3 0.6 3.8 1.1 110 12 115 255 9.7 0 9.8 9.6 06/09/2005 04:10:00 3.4 0.7 4.9 1.5 3.4 0.7 4.9 1.5 2.5 0.7 4.6 1.1 98 13 124 255 9.8 0 10.1 9.6 06/09/2005 04:20:00 3.2 0.5 4.2 1.9 3.1 0.5 4.6 1.9 2.2 0.6 3.8 0.7 90 11 88 255 10 0 10.1 9.8 06/09/2005 04:30:00 3.1 0.5 4.6 1.9 3.2 0.5 4.2 2.3 2.1 0.6 3.4 0.4 86 11 86 255 10 0 10.1 9.8 06/09/2005 04:40:00 2.9 0.5 4.2 1.1 2.8 0.6 3.8 1.1 2 0.6 3.4 0.4 98 9 111 255 10.2 0 10.3 10.1 06/09/2005 04:50:00 3.1 0.5 4.2 1.9 3.1 0.6 4.6 1.9 2.2 0.5 3.8 1.1 94 15 78 255 10.3 0 10.6 10.3 06/09/2005 05:00:00 2.9 0.5 3.8 1.5 2.9 0.5 4.2 1.5 2.2 0.5 3.4 0.7 93 18 105 255 10.6 0 10.9 10.6 06/09/2005 05:10:00 2.9 0.5 4.6 1.5 2.9 0.5 4.6 1.5 2.2 0.5 3.8 1.1 91 11 91 255 11.1 0.3 11.7 10.6 06/09/2005 05:20:00 2.3 0.7 3.8 0.7 2.3 0.7 3.8 0.7 1.8 0.5 3 0.7 106 16 102 255 11.7 0 11.9 11.7 06/09/2005 05:30:00 3.1 0.8 4.9 1.1 3.1 0.8 4.9 1.1 2.5 0.8 4.2 0.7 104 17 100 255 11.9 0 12.2 11.9 06/09/2005 05:40:00 2.3 0.7 3.8 0.4 2.3 0.6 4.2 0.7 1.8 0.7 3.4 0.4 92 19 90 255 12.5 0.2 13 12.2 06/09/2005 05:50:00 2.4 0.8 4.2 0.4 2.3 0.8 4.2 0.4 2 0.8 4.2 0.4 73 17 86 255 13.6 0.2 14.4 13 06/09/2005 06:00:00 2.4 0.7 4.2 0.4 2.4 0.7 3.8 0.4 2.1 0.8 3.8 0.4 41 16 66 255 14.5 0.1 15.2 14.1 06/09/2005 06:10:00 2.7 0.8 4.6 0.7 2.7 0.8 4.9 0.7 2.2 0.7 3.8 0.4 60 20 50 255 14.1 0.2 14.9 13.5 06/09/2005 06:20:00 2.4 0.7 3.8 0.4 2.4 0.7 3.8 0.4 2.1 0.7 3.8 0.4 59 23 77 255 13.7 0 14.1 13.5 06/09/2005 06:30:00 2.3 0.8 4.6 0.4 2.3 0.8 4.6 0.4 2 0.6 3.8 0.4 50 15 63 255 14 0.2 14.6 13.5 06/09/2005 06:40:00 2.2 0.6 3.8 0.7 2.2 0.7 3.8 0.4 1.9 0.7 3.4 0.4 51 17 38 255 15.1 0.3 16 14.6 06/09/2005 06:50:00 4 0.9 6.5 1.1 4 0.9 6.5 1.5 3.6 1 5.3 0.7 46 15 91 255 15.6 0 16.3 15.5 06/09/2005 07:00:00 4.2 0.8 6.5 1.5 4.2 0.8 6.1 1.9 3.6 0.9 6.5 1.9 43 13 41 255 15.5 0 16 15.5 06/09/2005 07:10:00 3.1 0.8 4.9 1.5 3.1 0.8 4.9 1.5 2.6 0.8 4.6 0.7 34 20 41 255 15.7 0 16.3 15.5 06/09/2005 07:20:00 4 1.1 6.8 1.9 4 1.1 6.8 1.9 3.4 1.1 6.5 1.1 32 19 22 255 15.7 0 16.3 15.5 06/09/2005 07:30:00 3.2 0.8 5.3 1.5 3.2 0.8 5.3 1.1 2.7 0.8 4.9 0.7 25 19 40 255 15.9 0.2 16.6 15.7 06/09/2005 07:40:00 3.5 0.8 5.7 1.5 3.5 0.7 5.7 2.3 2.9 0.7 4.9 1.5 49 17 32 255 16.1 0 16.3 16 06/09/2005 07:50:00 4.2 1 6.8 2.3 4.2 1 6.5 1.9 3.4 1.1 6.1 1.1 18 20 7 255 16.2 0 16.6 16.3 06/09/2005 08:00:00 5 0.9 7.6 1.9 5 0.9 7.6 1.9 3.8 1.2 6.8 0.7 20 15 20 255 15.4 0.4 16.3 14.9 06/09/2005 08:10:00 4.6 0.8 6.5 2.3 4.6 0.8 6.5 2.6 3.8 1 6.5 1.5 24 12 34 255 15.2 0.1 15.7 14.9 06/09/2005 08:20:00 5.4 1 8.8 3 5.4 1 8.8 3.4 4.4 1.1 7.6 1.9 30 17 35 255 15.6 0 16 15.5 06/09/2005 08:30:00 6.5 1.5 10.3 3 6.5 1.5 10.3 2.6 5.3 1.7 9.5 1.5 14 14 15 255 16 0 16.3 15.7 06/09/2005 08:40:00 5.7 1.3 9.5 2.6 5.7 1.4 9.1 2.3 4 1.5 8.8 0.4 5 15 352 255 16.1 0 16.6 16 06/09/2005 08:50:00 6.1 1.5 9.5 3 6 1.5 9.9 2.6 4.4 1.5 8.4 0.7 6 13 0 255 16.2 0 16.8 16 06/09/2005 09:00:00 4.6 1.3 7.6 1.5 4.6 1.3 8 1.1 3.4 1.1 6.1 0.7 14 17 19 255 16.5 0.2 16.8 16 06/09/2005 09:10:00 4.3 1.5 8 0.4 4.3 1.5 8.4 0.4 3.3 1.3 7.2 0.4 18 18 18 255 15.9 0 16.3 15.7 06/09/2005 09:20:00 4.6 1.3 8 0.7 4.6 1.3 8 0.7 3.5 1.3 7.2 1.1 24 21 28 255 16.1 0 16.3 16.3 06/09/2005 09:30:00 5.2 1.3 8.4 1.5 5.2 1.3 8.8 1.5 4.4 1.7 8.8 0.4 22 15 20 255 16.4 0.2 16.8 16.3 06/09/2005 09:40:00 4.8 1.3 8.8 1.9 4.8 1.3 8 2.3 3.9 1.4 7.2 1.1 31 22 53 255 17.6 0 18 16.8 06/09/2005 09:50:00 6.4 1.3 9.1 3 6.4 1.3 9.1 3.4 5.2 1.5 9.1 1.5 29 15 32 255 17.2 0.4 18 16.8 06/09/2005 10:00:00 6.8 1.2 9.9 3.8 6.8 1.2 9.5 3.8 5.5 1.6 8.8 1.1 27 17 23 255 17.1 0.7 18.5 16.3 06/09/2005 10:10:00 7 1.3 10.3 3.8 7 1.3 10.3 3.4 5.7 1.4 9.9 1.9 17 15 350 255 19 0.1 19.4 18.5 06/09/2005 10:20:00 6.3 1.2 9.5 3 6.3 1.2 9.1 3.4 5.4 1.3 8.8 2.3 18 11 7 255 19.1 0.2 20 18.5 06/09/2005 10:30:00 5.1 1.2 8 2.6 5.1 1.2 8 2.3 3.8 1.2 7.2 1.5 13 17 28 255 19.7 0.2 20.5 19.1 06/09/2005 10:40:00 5.8 1.2 8.8 2.6 5.8 1.2 8.4 2.3 4.8 1.3 8 1.5 23 15 26 255 18.9 0.4 20.3 18.5 06/09/2005 10:50:00 4.6 0.6 6.1 2.6 4.5 0.7 6.1 1.9 3.2 1 5.3 1.1 10 17 15 255 18.7 0.2 19.1 18.2 06/09/2005 11:00:00 4.2 0.8 6.5 1.9 4.2 0.9 6.8 1.5 3.3 1.1 6.8 0.4 27 23 55 255 18.3 0.1 18.8 18 06/09/2005 11:10:00 4.2 1 6.8 1.5 4.2 0.9 6.8 1.5 3.4 1.1 5.7 0.4 11 18 16 255 19 0.2 19.7 18.2 06/09/2005 11:20:00 4.4 1.6 7.6 0.4 4.3 1.5 7.6 0.4 3.7 1.3 6.5 0.4 32 13 11 255 19.2 0 19.7 18.8 06/09/2005 11:30:00 3.5 1.4 7.2 1.1 3.4 1.4 6.8 1.1 2.8 1.3 6.1 0.4 10 32 19 255 19.6 0.4 20.3 19.1 06/09/2005 11:40:00 4.3 1.1 7.6 1.5 4.3 1.1 7.2 1.9 3.6 1.2 6.5 1.1 49 20 35 255 20 0 20.5 19.7 06/09/2005 11:50:00 3.9 1.3 6.5 0.4 4 1.3 6.8 1.1 3.3 1.4 6.5 0.4 33 24 35 255 20.3 0.1 20.5 20 06/09/2005 12:00:00 5.4 1 8.8 2.3 5.4 1 8.8 2.6 4.4 1.3 8.4 0.4 36 21 52 255 20.8 0.2 21.4 20.5 06/09/2005 12:10:00 4.2 1 6.8 1.9 4.2 1 6.8 1.5 3.6 1 6.5 0.4 53 23 59 255 20.8 0.2 21.4 20.5 06/09/2005 12:20:00 6.4 1.1 9.9 3 6.3 1.2 9.5 3 5.3 1.3 8.8 1.9 44 13 30 255 21.1 0 21.4 20.8 06/09/2005 12:30:00 7.1 1.5 10.7 4.2 7 1.5 11.1 4.2 5.6 1.5 9.5 2.3 32 18 58 255 21 0.2 21.4 20.5 06/09/2005 12:40:00 7.7 1.5 11.1 4.6 7.6 1.5 11.1 4.6 6.2 1.6 9.9 3 24 13 28 255 20.3 0.1 20.8 20 06/09/2005 12:50:00 5.8 1.1 9.1 3.4 5.8 1 8.8 3 4.8 1.2 8 1.5 32 17 16 255 19.5 0 20 19.1 06/09/2005 13:00:00 5.4 1.5 9.5 1.9 5.4 1.5 9.5 1.9 4.7 1.4 8.8 1.5 45 22 22 255 18.7 0.2 19.4 18.2 06/09/2005 13:10:00 6.6 1.7 10.3 1.9 6.6 1.7 10.3 1.9 5.4 1.7 9.1 1.9 24 18 38 255 18.7 0 19.1 18.5 06/09/2005 13:20:00 5.6 1.4 9.9 2.3 5.6 1.5 9.9 2.3 4.6 1.3 8.4 1.5 32 18 33 255 19 0.1 19.4 18.5 06/09/2005 13:30:00 8.4 1.6 12.6 4.2 8.4 1.6 13 4.6 6.5 1.8 11.8 1.9 17 12 34 255 19.4 0.3 20.5 18.8 06/09/2005 13:40:00 7.5 1.7 12.2 3.8 7.5 1.7 11.8 3.4 6.1 1.9 10.7 1.9 22 14 27 255 20.3 0.1 21.1 20 06/09/2005 13:50:00 8.3 1.3 11.8 4.6 8.2 1.4 12.2 4.2 6.3 1.9 11.1 2.3 20 13 4 255 20.8 0.2 21.4 20 06/09/2005 14:00:00 8.3 1.5 11.8 4.9 8.2 1.6 11.8 4.6 6.4 1.8 11.8 2.3 23 16 19 255 19.7 0.5 21.1 19.1 06/09/2005 14:10:00 8.6 1.5 12.2 4.6 8.6 1.5 11.8 4.2 7.4 1.5 12.2 3.4 33 13 11 255 19 0.3 19.7 18.5 06/09/2005 14:20:00 8.6 1.7 12.6 4.2 8.5 1.7 13 4.6 7.1 2 12.2 2.6 26 13 19 255 19.4 0.4 20.5 18.5 06/09/2005 14:30:00 8.8 1.3 12.2 5.7 8.7 1.3 12.6 5.3 7.1 1.5 11.1 4.2 33 13 32 255 20 0 20.5 19.7 06/09/2005 14:40:00 7.7 1.6 12.2 4.2 7.7 1.6 11.8 4.6 6.1 1.7 10.7 1.9 22 16 351 255 20.9 0.5 22.3 20 06/09/2005 14:50:00 6.8 1.7 11.1 3 6.8 1.8 11.1 3.4 5.7 2 11.1 1.5 22 14 26 255 21.4 0.6 22.6 20.5 06/09/2005 15:00:00 6 1.3 9.1 3 5.9 1.5 9.5 2.6 4.6 1.6 8.4 1.5 25 16 48 255 20.1 0.2 21.1 19.7 06/09/2005 15:10:00 6.5 1.5 9.9 1.9 6.4 1.5 9.5 1.5 4.9 1.8 8.8 0.4 14 20 18 255 20.3 0 20.8 20 06/09/2005 15:20:00 6.1 1.4 9.5 2.3 6 1.5 9.1 2.6 4.6 1.6 8.4 1.1 7 15 33 255 20.8 0.1 21.4 20.5 06/09/2005 15:30:00 5.7 1.5 8.8 1.1 5.6 1.6 8.8 0.7 4.2 1.7 8.4 0.7 10 16 26 255 21.2 0 21.7 20.8 06/09/2005 15:40:00 5.4 1.2 9.1 2.3 5.3 1.3 8.8 1.9 3.9 1.4 7.6 0.7 6 18 4 255 20.6 0.1 21.1 20.5 06/09/2005 15:50:00 5.8 1.7 10.3 1.5 5.8 1.8 10.7 1.1 4.5 2.1 9.9 0.7 17 18 30 255 20.3 0 20.5 20 06/09/2005 16:00:00 6.2 1.6 9.5 2.6 6.1 1.6 9.9 2.6 4.5 1.7 8.4 0.7 11 17 17 255 19.7 0.1 20 19.4 06/09/2005 16:10:00 5.2 1.3 8.4 1.5 5.2 1.4 8.4 1.5 4 1.7 8.4 0.4 9 15 354 255 19.3 0.1 19.7 19.1 06/09/2005 16:20:00 5.8 1.6 9.9 2.6 5.8 1.6 9.9 2.3 4.6 1.7 8.4 0.4 17 15 21 255 19 0 19.7 18.5 06/09/2005 16:30:00 6.5 1.3 9.5 3.4 6.4 1.3 9.5 3 5 1.5 8.4 1.1 20 16 358 255 18.6 0.1 18.8 18.2 06/09/2005 16:40:00 5.7 1.3 9.5 2.6 5.6 1.3 9.5 3 4.6 1.4 9.9 1.1 24 18 34 255 18.3 0 18.8 18 06/09/2005 16:50:00 5.4 1 8 3 5.4 1 7.6 3 4.2 1.2 7.6 1.9 28 16 20 255 18 0 18.2 17.7 06/09/2005 17:00:00 6 1.3 9.9 3.4 6 1.3 10.3 3.4 4.3 1.3 8 1.5 16 14 350 255 17.7 0 18.2 17.4 06/09/2005 17:10:00 6.5 1.5 10.7 3.4 6.4 1.5 10.7 3.4 4.9 1.5 9.1 1.9 22 13 22 255 17.6 0 17.7 17.4 06/09/2005 17:20:00 7.4 1.2 11.1 3.4 7.4 1.2 11.1 3.8 6.1 1.3 9.5 2.3 27 13 16 255 17.5 0.1 17.7 17.1 06/09/2005 17:30:00 6.9 1.3 10.3 2.6 6.9 1.3 10.3 3 5.7 1.5 9.5 1.1 26 17 25 255 17.2 0 17.4 17.1 06/09/2005 17:40:00 6.6 1.5 10.7 3 6.6 1.5 10.7 3 5.3 1.3 9.1 2.3 39 16 38 255 17.1 0 17.1 16.8 06/09/2005 17:50:00 6.3 1.3 9.5 3.4 6.2 1.3 9.5 3.4 5.2 1.3 8.8 1.9 29 17 10 255 17.4 0.1 17.7 16.8 06/09/2005 18:00:00 7.5 1.2 10.3 4.9 7.4 1.2 10.3 4.6 5.8 1.5 9.9 2.6 22 13 354 255 17.5 0 17.7 17.1 06/09/2005 18:10:00 8.2 1.4 11.8 5.3 8.2 1.5 12.6 4.9 6.9 1.7 11.1 1.9 27 13 28 255 17.3 0 17.4 17.1 06/09/2005 18:20:00 8.2 1.4 11.5 4.2 8.1 1.5 11.5 4.2 6.8 1.8 11.8 2.6 31 14 30 255 16.9 0.1 17.1 16.8 06/09/2005 18:30:00 7.3 1.5 10.7 3.4 7.3 1.5 10.7 3.4 6.1 1.6 10.3 2.6 28 13 14 255 16.7 0 16.8 16.6 06/09/2005 18:40:00 7.7 1.5 11.5 4.6 7.7 1.5 11.5 4.6 6.4 1.6 11.1 2.6 36 13 51 255 16.4 0 16.8 16.3 06/09/2005 18:50:00 9.6 1.5 13.3 4.9 9.6 1.5 13.3 4.6 8.3 1.6 12.2 4.2 34 12 27 255 16.6 0 16.8 16.3 06/09/2005 19:00:00 8.9 1.8 14.1 5.3 8.9 1.8 14.5 5.3 7.7 1.9 12.6 3.8 34 14 33 255 16.4 0 16.8 16.3 06/09/2005 19:10:00 9 1.5 13.7 4.9 9 1.6 14.1 5.3 7.3 1.8 13.3 3 30 15 37 255 16.4 0 16.8 16.3 06/09/2005 19:20:00 8.2 1.5 11.8 4.6 8.2 1.5 11.8 4.2 6.7 1.6 10.3 3.4 36 16 27 255 16.4 0.1 16.8 16.3 06/09/2005 19:30:00 8.7 1.8 14.1 3.8 8.6 1.9 14.1 3.4 7.2 1.9 12.2 3.4 36 16 27 255 16.1 0 16.8 15.7 06/09/2005 19:40:00 8 1.7 14.9 3.4 7.9 1.7 15.3 3.4 6.3 1.9 10.7 1.5 31 18 53 255 15.7 0.1 16.3 15.7 06/09/2005 19:50:00 8.2 1.8 12.6 3 8.2 1.8 12.6 3.4 6.6 2 12.6 1.5 24 17 0 255 15.5 0.1 16.3 15.2 06/09/2005 20:00:00 7.8 1.3 11.8 4.9 7.7 1.3 11.8 4.9 6.3 1.6 10.3 3 28 14 40 255 15.1 0.1 15.7 14.9 06/09/2005 20:10:00 8.6 1.5 11.8 4.9 8.6 1.5 12.2 4.9 7.1 1.5 11.5 2.6 36 12 19 255 15 0 15.5 14.6 06/09/2005 20:20:00 7.1 1.5 12.2 3.4 7.1 1.5 11.8 3.4 5.6 1.6 9.5 2.3 25 16 19 255 14.8 0.1 15.5 14.6 06/09/2005 20:30:00 7.7 1.2 11.1 4.6 7.6 1.2 11.1 4.9 6.3 1.5 9.9 3 23 12 37 255 14.6 0.1 15.2 14.6 06/09/2005 20:40:00 6.9 1.1 9.5 3.8 6.8 1.1 9.9 4.2 5.4 1.3 8.4 2.6 19 13 3 255 14.6 0 15.2 14.6 06/09/2005 20:50:00 7.4 1.3 10.7 3.8 7.4 1.2 11.1 4.2 5.5 1.3 8.4 2.3 19 12 2 255 14.5 0 14.9 14.6 06/09/2005 21:00:00 8 1.5 13 4.9 8 1.5 12.6 4.6 6.2 1.7 11.5 3 18 13 12 255 14.4 0 14.9 14.4 06/09/2005 21:10:00 9.1 1.7 13.3 4.6 9.1 1.7 13.3 4.6 6.8 2.2 12.6 2.6 14 14 4 255 14.5 0 15.2 14.4 06/09/2005 21:20:00 9.2 1.9 14.1 4.2 9.2 1.9 14.1 4.9 6.9 1.9 14.1 2.3 14 11 6 255 14.5 0.1 14.9 14.4 06/09/2005 21:30:00 8 1.7 12.6 3.8 8 1.8 12.6 3.8 6 2 11.1 2.3 15 14 9 255 14.3 0.1 14.9 14.1 06/09/2005 21:40:00 6.6 1.1 9.9 3 6.5 1.2 9.5 3 5.1 1.2 8.8 2.6 21 15 25 255 14.2 0.1 14.6 13.8 06/09/2005 21:50:00 6.6 1.3 10.3 3.4 6.6 1.3 10.3 2.6 5.3 1.5 9.1 1.5 23 13 19 255 13.9 0 14.6 13.8 06/09/2005 22:00:00 8 1.4 12.6 4.6 8 1.5 13 4.6 6.2 1.5 11.1 3 18 14 25 255 13.9 0 13.8 13.8 06/09/2005 22:10:00 7.3 1.2 11.1 4.6 7.3 1.2 10.7 4.6 5.6 1.5 9.5 2.6 19 13 6 255 13.8 0 14.1 13.5 06/09/2005 22:20:00 6.7 1.5 10.3 2.6 6.7 1.5 11.1 2.6 5.2 1.7 9.5 1.5 18 12 23 255 13.8 0 13.8 13.5 06/09/2005 22:30:00 6.9 1.2 10.3 3.8 6.9 1.3 10.7 3.4 5.7 1.5 9.5 1.5 24 15 12 255 13.8 0 14.1 13.5 06/09/2005 22:40:00 6.7 1.3 10.3 3.4 6.7 1.3 10.3 2.6 5.3 1.4 10.3 2.3 24 13 12 255 14 0 14.6 13.8 06/09/2005 22:50:00 5.7 1.3 9.1 3 5.6 1.3 9.1 2.6 4.3 1.4 8.4 1.1 25 17 17 255 13.9 0 14.6 13.8 06/09/2005 23:00:00 5.5 1.4 9.9 2.3 5.5 1.5 9.9 1.9 4.2 1.5 8.8 1.1 30 16 40 255 14.1 0.1 14.6 13.8 06/09/2005 23:10:00 5.2 1 8 2.6 5.2 1 8.4 2.3 4.3 1 6.8 1.9 38 15 37 255 14.2 0 14.6 14.1 06/09/2005 23:20:00 5.1 1.2 8.8 2.3 5.1 1.2 8.8 2.3 4.1 1.2 7.6 1.5 33 17 21 255 14 0 14.6 13.8 06/09/2005 23:30:00 4.1 1 6.8 1.9 4.1 1 6.1 1.9 3.3 1 6.1 0.7 41 20 21 255 13.9 0 14.6 13.8 06/09/2005 23:40:00 3.8 1.2 7.2 0.7 3.7 1.3 7.2 0.7 3 1.2 5.7 0.4 44 21 54 255 13.8 0 13.8 13.5 06/09/2005 23:50:00 3.1 1.2 5.7 0.7 3 1.2 5.7 0.7 2.6 1 4.9 0.7 61 35 41 255 13.5 0 13.8 13.3 06/10/2005 00:00:00 3.1 1.2 6.8 1.1 3.2 1.2 6.8 1.1 2.5 1.1 6.1 0.7 78 29 52 255 12.9 0.1 13.5 12.7 06/10/2005 00:10:00 2.9 0.7 4.9 1.5 2.8 0.7 5.3 1.1 2.2 0.8 4.2 0.7 94 26 34 255 12.9 0 13.3 12.7 06/10/2005 00:20:00 2.6 0.7 4.9 1.1 2.6 0.7 5.3 0.4 1.8 0.8 4.6 0.4 92 20 86 255 12.5 0.1 12.7 12.2 06/10/2005 00:30:00 2.8 0.9 4.6 0.4 2.7 0.9 4.6 0.4 2 1 4.2 0.4 78 17 78 255 12.5 0 12.7 12.2 06/10/2005 00:40:00 3.2 0.9 5.7 0.7 3.2 0.9 4.9 0.7 2.3 0.9 4.2 0.4 88 18 104 255 12.7 0 13 12.5 06/10/2005 00:50:00 3.7 1 6.5 1.5 3.7 0.9 6.1 1.1 2.9 1 6.1 0.7 58 22 30 255 12.8 0 13.3 12.7 06/10/2005 01:00:00 3.9 1 6.8 1.1 3.9 1 6.5 1.9 3.3 1.1 5.7 1.1 45 20 42 255 12.9 0.1 13 12.7 06/10/2005 01:10:00 3.4 1.2 6.8 0.4 3.4 1.2 6.5 0.7 2.7 1.2 6.1 0.4 54 24 20 255 13.1 0 13.3 13 06/10/2005 01:20:00 2.2 0.7 3.8 0.4 2.2 0.7 4.2 0.4 1.4 0.7 3 0.4 78 21 92 255 13.1 0.1 13.3 12.7 06/10/2005 01:30:00 2.5 1 4.9 0.4 2.4 1 4.9 0.4 1.8 0.9 4.6 0.4 71 24 79 255 12.7 0 12.7 12.5 06/10/2005 01:40:00 3.7 0.7 5.7 1.5 3.8 0.7 5.7 1.5 2.8 1 5.3 0.4 66 15 52 255 12.5 0 12.7 12.5 06/10/2005 01:50:00 3.9 0.6 6.1 2.3 3.9 0.7 6.1 2.6 2.8 0.8 5.3 1.5 81 13 60 255 12.3 0 12.5 12.2 06/10/2005 02:00:00 3.2 0.8 5.3 1.1 3.3 0.8 5.3 1.1 2.4 0.8 4.2 0.4 53 17 51 255 12.4 0 12.5 12.2 06/10/2005 02:10:00 3.7 0.6 5.7 2.3 3.7 0.6 5.7 2.3 3 0.7 4.9 1.1 44 11 56 255 12.3 0 12.5 12.2 06/10/2005 02:20:00 4.5 0.6 6.1 2.6 4.5 0.6 6.1 3 3.8 0.7 5.7 1.9 36 9 47 255 12.1 0 12.2 11.9 06/10/2005 02:30:00 4.5 0.7 6.5 2.6 4.5 0.7 6.5 2.6 3.6 0.8 5.7 1.1 33 10 34 255 11.8 0 12.2 11.7 06/10/2005 02:40:00 2.6 0.7 4.6 1.1 2.5 0.7 4.6 1.1 1.6 0.8 3.8 0.4 26 12 21 255 11.4 0.2 11.7 10.9 06/10/2005 02:50:00 2.4 0.7 4.2 0.7 2.3 0.7 3.8 0.4 1.6 0.8 3.4 0.4 65 16 68 255 10.6 0 11.1 10.3 06/10/2005 03:00:00 2.5 0.6 4.2 1.1 2.4 0.6 4.2 1.1 1.8 0.6 3.4 0.7 98 18 76 255 10.5 0 10.6 10.3 06/10/2005 03:10:00 2.5 0.7 3.8 0.7 2.5 0.6 3.8 0.7 1.8 0.7 3.4 0.4 94 14 90 255 10.6 0 10.6 10.6 06/10/2005 03:20:00 3 0.4 4.2 1.9 2.9 0.4 4.2 1.5 2.1 0.5 3.4 1.1 97 9 109 255 10.3 0 10.6 10.3 06/10/2005 03:30:00 3.2 0.5 4.6 1.9 3.2 0.6 4.6 1.9 2.3 0.6 4.2 0.7 96 10 87 255 10.3 0 10.6 10.3 06/10/2005 03:40:00 3.6 0.6 5.3 1.9 3.6 0.6 5.3 1.9 2.6 0.7 4.9 0.7 100 13 102 255 10.4 0 10.6 10.3 06/10/2005 03:50:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.7 1.5 0.6 3 0.4 92 13 80 255 10.4 0 10.6 10.3 06/10/2005 04:00:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 1.1 1.6 0.6 3.4 0.4 102 12 94 255 10.3 0.2 10.6 10.1 06/10/2005 04:10:00 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.3 2.3 0.6 4.2 0.7 91 13 94 255 9.8 0.2 10.3 9.6 06/10/2005 04:20:00 3 0.6 4.2 1.1 2.9 0.6 4.2 1.1 2.2 0.6 3.8 0.4 109 12 101 255 10.2 0 10.6 9.8 06/10/2005 04:30:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.1 2.4 0.6 4.2 0.4 110 11 112 255 10.4 0 10.6 10.3 06/10/2005 04:40:00 4.2 0.6 5.7 2.3 4.1 0.6 5.7 2.3 3.1 0.7 4.9 1.1 109 11 93 255 10.3 0 10.6 10.3 06/10/2005 04:50:00 4.3 0.5 5.3 3 4.3 0.5 5.3 2.6 3.4 0.6 4.9 1.5 102 7 100 255 10.7 0.1 10.9 10.6 06/10/2005 05:00:00 4.3 0.4 5.3 3 4.3 0.4 5.3 3 3.5 0.5 4.9 2.3 99 7 109 255 11.1 0 11.4 10.9 06/10/2005 05:10:00 3.7 0.6 5.3 1.9 3.7 0.6 4.9 2.3 2.8 0.7 4.6 1.1 97 9 97 255 11.5 0 11.7 11.1 06/10/2005 05:20:00 3.1 0.5 4.2 1.9 3 0.5 4.2 1.5 2.3 0.6 3.8 0.4 111 11 98 255 11.7 0 11.9 11.7 06/10/2005 05:30:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.7 1.6 0.5 2.6 0.4 107 12 106 255 12.1 0 12.2 11.9 06/10/2005 05:40:00 2.7 0.6 3.8 1.1 2.6 0.6 3.8 0.7 2 0.6 3.4 0.4 118 16 105 255 12.3 0 12.2 12.2 06/10/2005 05:50:00 2.5 0.7 3.8 0.4 2.4 0.7 3.8 0.4 1.8 0.7 3.8 0.4 113 16 117 255 12.5 0 12.7 12.2 06/10/2005 06:00:00 1.7 0.9 3.4 0.4 1.7 0.9 3.4 0.4 1.4 0.8 3.4 0.4 88 28 104 255 13.1 0.1 13.3 12.7 06/10/2005 06:10:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 91 21 92 255 13.4 0 13.5 13.3 06/10/2005 06:20:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 75 17 56 255 13.3 0 13.8 13.3 06/10/2005 06:30:00 1.3 0.6 3 0.4 1.1 0.6 3.4 0.4 0.9 0.5 2.6 0.4 73 19 30 255 13.4 0 13.8 13.3 06/10/2005 06:40:00 1.8 0.4 2.6 1.1 1.7 0.5 3 0.7 1.3 0.6 2.6 0.4 23 11 27 255 13.4 0 13.8 13.3 06/10/2005 06:50:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 71 12 58 255 13.5 0 13.8 13.3 06/10/2005 07:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 92 17 101 255 13.5 0.1 13.8 13.3 06/10/2005 07:10:00 0.8 0.4 2.3 0.4 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 91 28 65 255 13.7 0 14.4 13.5 06/10/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 74 39 40 255 13.9 0 14.4 13.8 06/10/2005 07:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 79 9 79 255 14.2 0 14.6 13.8 06/10/2005 07:40:00 0.9 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 29 29 7 255 14.4 0 14.9 14.4 06/10/2005 07:50:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 22 19 34 255 14.8 0.2 15.5 14.6 06/10/2005 08:00:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 26 11 25 255 15.2 0.3 16.3 15.2 06/10/2005 08:10:00 1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.5 2.3 0.4 37 32 18 255 16.6 0.4 17.4 16 06/10/2005 08:20:00 1.4 0.7 2.6 0.4 1.3 0.7 3 0.4 1 0.6 2.3 0.4 19 26 3 255 17.3 0.1 17.7 16.8 06/10/2005 08:30:00 1.3 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.1 0.7 3 0.4 17 35 358 255 17.3 0.2 18 16.8 06/10/2005 08:40:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.8 0.4 2.3 0.4 15 24 20 255 16.6 0 16.8 16.6 06/10/2005 08:50:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.5 2.3 0.4 353 39 328 255 16.8 0 17.1 16.8 06/10/2005 09:00:00 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 344 24 339 255 17.2 0 17.4 16.8 06/10/2005 09:10:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.6 3 0.4 3 22 14 255 18 0.5 19.1 17.4 06/10/2005 09:20:00 1.6 0.7 3.8 0.4 1.5 0.7 3.4 0.4 1.3 0.7 3.4 0.4 345 33 321 255 19.3 0 19.7 19.1 06/10/2005 09:30:00 1.5 0.7 3.4 0.4 1.3 0.7 3 0.4 1.2 0.7 3.4 0.4 324 45 331 255 18.8 0 19.4 18.5 06/10/2005 09:40:00 1.5 0.6 3 0.4 1.5 0.7 3 0.4 1.1 0.6 2.3 0.4 290 24 281 255 18.5 0.1 19.1 18.2 06/10/2005 09:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.6 2.3 0.4 292 27 304 255 18.4 0.2 19.1 18 06/10/2005 10:00:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.7 3 0.4 313 18 293 255 18.2 0.1 18.8 18 06/10/2005 10:10:00 1.6 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.9 3.4 0.4 295 17 301 255 18.6 0.2 19.4 18.2 06/10/2005 10:20:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.4 0.8 3.4 0.4 283 23 290 255 18.4 0.1 18.8 18.2 06/10/2005 10:30:00 2 0.7 3 0.4 2 0.7 3.4 0.4 1.7 0.6 3 0.4 292 33 269 255 18.9 0.3 19.7 18.2 06/10/2005 10:40:00 1.8 0.9 3.8 0.4 1.7 0.9 3.8 0.4 1.4 0.9 3.8 0.4 305 22 303 255 19.1 0 19.4 18.8 06/10/2005 10:50:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 1.6 0.8 3.8 0.4 321 18 311 255 19.3 0.3 20 18.8 06/10/2005 11:00:00 2.1 0.9 4.6 0.4 2.1 0.8 4.6 0.4 2 0.9 4.6 0.4 287 32 275 255 20.1 0 20.5 20 06/10/2005 11:10:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.7 0.7 3.4 0.4 283 22 274 255 19.5 0.3 20.5 18.8 06/10/2005 11:20:00 2.5 0.8 4.6 0.4 2.4 0.9 4.2 0.4 2 1 4.2 0.4 303 28 273 255 19.9 0.4 20.5 18.8 06/10/2005 11:30:00 1.5 0.8 4.2 0.4 1.3 0.8 4.2 0.4 1.2 0.8 3.8 0.4 262 69 250 255 20.6 0.2 21.1 20 06/10/2005 11:40:00 2.2 1 6.1 0.4 2.1 0.9 5.3 0.4 2 1 4.9 0.4 281 23 284 255 20.3 0.3 21.1 20 06/10/2005 11:50:00 2.4 0.9 4.2 0.4 2.3 0.9 4.2 0.4 1.9 0.8 4.6 0.4 271 38 257 255 20.6 0.4 21.1 20 06/10/2005 12:00:00 2.8 0.8 4.9 0.4 2.7 0.8 4.6 0.4 2.1 0.8 4.2 0.4 287 33 340 255 21.7 0.3 22.3 21.1 06/10/2005 12:10:00 2.6 1 4.6 0.4 2.4 1 4.6 0.4 2 1 4.2 0.4 304 36 297 255 21.6 0 22 21.4 06/10/2005 12:20:00 2.7 0.7 4.9 0.4 2.6 0.7 4.6 0.4 2.2 0.8 4.6 0.4 303 18 257 255 21.5 0 21.7 21.1 06/10/2005 12:30:00 3.1 0.8 4.9 1.1 3 0.8 4.9 1.1 2.5 0.8 4.2 0.4 313 19 304 255 21.3 0 21.4 21.1 06/10/2005 12:40:00 3.4 0.9 5.7 0.7 3.3 0.9 5.3 1.1 2.9 1 5.7 0.4 302 18 305 255 21.3 0 21.4 21.1 06/10/2005 12:50:00 3.9 1 6.5 1.5 3.9 1 6.5 1.5 3.1 1.1 6.1 0.4 296 17 291 255 21.1 0 21.4 20.8 06/10/2005 13:00:00 3.6 1.2 7.6 0.4 3.5 1.2 6.8 0.4 3 1.2 5.3 0.4 299 18 298 255 21.3 0 21.7 21.1 06/10/2005 13:10:00 3.1 1.1 6.8 0.4 3 1.2 6.8 0.4 2.5 1.2 5.7 0.4 313 29 296 255 21.9 0.3 22.9 21.1 06/10/2005 13:20:00 3.6 1 5.7 1.1 3.4 1 5.7 1.1 2.8 0.9 4.9 0.4 310 19 293 255 21.9 0.2 22.6 21.7 06/10/2005 13:30:00 4 0.8 6.5 0.7 3.9 0.8 6.1 1.5 3.3 1 6.1 0.7 315 17 300 255 21.9 0.1 22.3 21.7 06/10/2005 13:40:00 4 0.8 6.1 1.5 3.8 0.9 6.1 1.1 3.1 1 6.1 1.1 321 20 311 255 22.1 0.4 23.2 21.7 06/10/2005 13:50:00 3.4 1.3 6.1 1.1 3.2 1.3 5.7 0.4 2.6 1.3 5.3 0.4 320 23 308 255 22.7 0.3 23.2 22.3 06/10/2005 14:00:00 3.7 0.8 5.7 1.9 3.6 0.8 6.1 1.5 2.9 0.9 5.3 0.4 297 20 338 255 22 0 22.3 21.7 06/10/2005 14:10:00 4.2 1 6.8 1.9 4.1 1.1 6.5 1.1 3.5 1.2 6.8 0.4 304 18 338 255 21.9 0.1 22 21.7 06/10/2005 14:20:00 3.8 1 6.5 1.1 3.7 1.1 6.1 0.7 3.1 1.3 5.7 0.4 311 18 318 255 21.6 0.1 22 21.1 06/10/2005 14:30:00 4.3 0.9 6.1 1.9 4.2 1 6.1 1.5 3.4 1.1 5.7 1.1 306 18 304 255 21.9 0 22.3 21.7 06/10/2005 14:40:00 3.5 1.1 6.5 1.1 3.2 1.1 6.5 0.7 2.5 1.2 5.3 0.4 322 22 282 255 21.6 0 22 21.4 06/10/2005 14:50:00 4.6 1 6.5 1.1 4.5 1 6.5 0.7 3.9 1.1 6.5 1.5 307 15 305 255 21.3 0 21.4 21.1 06/10/2005 15:00:00 3.9 1.2 6.5 1.5 3.8 1.2 6.5 1.1 2.9 1.3 6.1 0.4 303 17 317 255 20.7 0.1 21.1 20.5 06/10/2005 15:10:00 2.7 1 6.1 0.7 2.6 1.1 6.5 0.4 1.9 1 4.9 0.4 306 21 322 255 20.5 0 20.8 20.5 06/10/2005 15:20:00 3.2 0.8 4.9 1.5 3 0.9 4.9 0.7 2.1 0.9 4.6 0.4 316 15 328 255 20.3 0.1 20.5 20 06/10/2005 15:30:00 2.8 0.9 4.9 1.1 2.6 0.8 4.6 1.1 2.1 0.9 4.6 0.7 318 15 326 255 20.1 0 20.5 20 06/10/2005 15:40:00 1.7 0.9 4.2 0.4 1.6 1 3.8 0.4 1.3 0.9 3.8 0.4 288 21 314 255 20 0 20.5 19.7 06/10/2005 15:50:00 2.5 0.9 4.6 0.4 2.7 0.9 4.6 0.4 2 0.7 3.8 0.4 174 28 147 255 18.7 0.6 20 17.7 06/10/2005 16:00:00 4.4 1 6.8 1.5 4.3 1 6.5 1.9 3.6 1 5.7 1.1 142 12 143 255 17 0.3 17.7 16.3 06/10/2005 16:10:00 4.4 0.9 7.2 1.9 4.4 0.9 6.8 2.6 3.4 0.9 6.5 1.5 147 14 143 255 15.7 0.3 16.6 15.2 06/10/2005 16:20:00 2 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.5 0.6 2.6 0.4 174 15 157 255 14.8 0.2 15.5 14.4 06/10/2005 16:30:00 2.8 0.3 3.8 1.9 2.7 0.3 3.8 1.9 2 0.4 3 0.7 153 8 152 255 14.3 0 14.9 14.4 06/10/2005 16:40:00 1.7 0.4 3 0.7 1.6 0.4 3 0.7 1.2 0.4 1.9 0.4 119 27 79 255 14.4 0 14.9 14.4 06/10/2005 16:50:00 1.6 0.4 3 0.7 1.5 0.5 3 0.4 0.8 0.4 2.3 0.4 85 16 73 255 14.5 0 14.9 14.4 06/10/2005 17:00:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.2 0.6 2.6 0.4 122 6 134 255 14.6 0 14.9 14.6 06/10/2005 17:10:00 2.5 0.3 3 1.1 2.4 0.3 3 1.1 1.9 0.6 3 0.7 138 6 140 255 14.6 0 15.2 14.6 06/10/2005 17:20:00 2.5 0.4 3 1.1 2.5 0.4 3.4 0.7 1.7 0.5 3 0.4 124 5 126 255 14.9 0 15.5 14.6 06/10/2005 17:30:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 0.8 0.6 2.3 0.4 128 11 135 255 15 0 15.5 14.9 06/10/2005 17:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 128 7 113 255 14.8 0 15.5 14.6 06/10/2005 17:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 148 8 140 255 14.8 0.1 15.5 14.6 06/10/2005 18:00:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 137 21 154 255 14.7 0.1 15.2 14.6 06/10/2005 18:10:00 1 0.4 1.9 0.4 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 185 12 161 255 14.7 0.1 15.2 14.6 06/10/2005 18:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 137 66 202 255 14.6 0 15.2 14.6 06/10/2005 18:30:00 1.5 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 54 17 26 255 14.7 0.1 15.2 14.6 06/10/2005 18:40:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 0.9 0.5 2.6 0.4 69 19 52 255 14.6 0 15.2 14.6 06/10/2005 18:50:00 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.4 1.2 0.5 2.6 0.4 50 9 45 255 14.3 0.1 14.9 14.1 06/10/2005 19:00:00 1.8 0.3 2.6 0.7 1.7 0.4 2.3 0.4 1 0.5 1.9 0.4 72 14 70 255 14.2 0 14.6 14.4 06/10/2005 19:10:00 1.1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 77 18 104 255 14.3 0 14.9 14.4 06/10/2005 19:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 39 9 30 255 14.2 0.1 14.9 14.1 06/10/2005 19:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 37 2 49 255 14.3 0 14.9 14.4 06/10/2005 19:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 49 0 49 255 14.2 0 14.6 14.1 06/10/2005 19:50:00 1.1 0.6 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 116 20 130 255 14.1 0.2 14.6 13.8 06/10/2005 20:00:00 1.6 0.5 2.6 0.7 1.5 0.5 2.6 0.4 0.7 0.5 2.3 0.4 129 10 127 255 14 0.1 14.6 13.8 06/10/2005 20:10:00 1.8 0.6 3.4 0.7 1.7 0.6 3 0.4 0.9 0.5 2.3 0.4 105 12 112 255 13.9 0 14.6 13.8 06/10/2005 20:20:00 1.9 0.4 3 0.7 1.7 0.4 2.6 0.4 1.1 0.6 2.6 0.4 114 17 101 255 13.9 0 14.1 13.8 06/10/2005 20:30:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 0.7 0.5 2.3 0.4 84 11 85 255 13.9 0 14.4 13.8 06/10/2005 20:40:00 1.5 0.7 3 0.4 1.4 0.6 2.6 0.4 0.7 0.5 1.9 0.4 116 14 124 255 13.7 0 13.8 13.5 06/10/2005 20:50:00 1.8 0.6 3 0.7 1.6 0.7 3 0.4 0.8 0.5 2.6 0.4 107 15 111 255 13.5 0 13.5 13.5 06/10/2005 21:00:00 2.7 0.7 4.9 0.7 2.6 0.6 4.6 1.1 1.5 0.7 3.4 0.4 104 17 105 255 13.4 0 13.5 13.3 06/10/2005 21:10:00 2.8 0.8 4.6 1.1 2.6 0.8 4.6 0.7 1.6 0.9 3.8 0.4 103 22 112 255 13.3 0 13.5 13.3 06/10/2005 21:20:00 1.3 0.6 3 0.4 1.1 0.6 3 0.4 0.7 0.5 2.3 0.4 64 13 77 255 13.3 0 13.3 13 06/10/2005 21:30:00 1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 64 12 70 255 13.1 0.1 13.5 13 06/10/2005 21:40:00 2.2 0.5 3.4 1.1 2.1 0.5 3 0.7 0.8 0.5 2.3 0.4 96 9 109 255 12.9 0 13.3 12.7 06/10/2005 21:50:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 1 0.5 2.6 0.4 110 9 109 255 12.8 0 13 12.7 06/10/2005 22:00:00 1.9 0.6 3.4 0.4 1.8 0.7 3 0.4 0.6 0.5 1.9 0.4 107 9 112 255 12.7 0 13 12.5 06/10/2005 22:10:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 120 8 109 255 12.6 0 12.7 12.5 06/10/2005 22:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 83 30 51 255 12.5 0.1 12.7 12.2 06/10/2005 22:30:00 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.4 0 0.4 0.4 67 13 59 255 12.3 0 12.7 12.2 06/10/2005 22:40:00 1.3 0.6 2.6 0.4 1.1 0.7 2.3 0.4 0.5 0.3 1.9 0.4 89 13 80 255 12.3 0 12.7 12.2 06/10/2005 22:50:00 1.9 0.4 2.6 0.7 1.8 0.5 2.6 0.4 0.7 0.4 2.3 0.4 73 11 59 255 12.3 0 12.7 12.2 06/10/2005 23:00:00 2.4 0.2 3 1.9 2.3 0.3 3 1.5 1.1 0.5 2.3 0.4 91 9 85 255 12.3 0 12.7 12.2 06/10/2005 23:10:00 2.2 0.6 3.4 0.4 2 0.7 3 0.4 0.9 0.6 2.6 0.4 105 13 100 255 12.3 0 12.7 12.2 06/10/2005 23:20:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.1 1.3 0.6 2.6 0.4 89 9 96 255 12.4 0.1 12.7 12.2 06/10/2005 23:30:00 2.5 0.5 3.8 1.1 2.3 0.5 3.4 0.7 1.3 0.6 2.6 0.4 91 11 79 255 12.4 0 12.7 12.2 06/10/2005 23:40:00 2.4 0.5 4.2 1.1 2.3 0.5 4.2 1.1 1 0.6 2.6 0.4 81 9 49 255 12.4 0.1 12.7 12.2 06/10/2005 23:50:00 3 0.6 4.6 1.1 2.9 0.6 4.9 1.1 1.7 0.8 3.4 0.4 78 15 82 255 12.4 0 12.5 12.2 06/11/2005 00:00:00 3 0.6 4.6 1.5 2.9 0.5 4.6 1.1 1.6 0.6 3.4 0.4 84 9 64 255 12.3 0 12.5 12.2 06/11/2005 00:10:00 3.4 0.9 5.7 1.1 3.3 0.9 5.7 1.1 2.3 1 5.7 0.4 87 12 97 255 12.3 0 12.5 12.2 06/11/2005 00:20:00 2.6 0.5 4.2 1.5 2.5 0.5 3.8 1.1 1.2 0.7 3 0.4 106 13 101 255 12.4 0 12.5 12.2 06/11/2005 00:30:00 2.9 0.6 4.6 1.1 2.7 0.6 4.6 0.7 1.6 0.8 3 0.4 102 12 117 255 12.4 0 12.5 12.2 06/11/2005 00:40:00 2.4 0.7 4.2 0.4 2.3 0.7 4.2 0.4 1 0.7 2.6 0.4 103 18 103 255 12.4 0 12.5 12.5 06/11/2005 00:50:00 2.8 0.6 4.2 1.5 2.7 0.7 3.8 1.1 1.6 0.6 3 0.4 99 11 87 255 12.3 0 12.5 12.2 06/11/2005 01:00:00 3.2 0.6 4.9 1.5 3.2 0.7 4.9 1.5 1.7 0.8 3.8 0.4 73 14 66 255 12.3 0 12.2 12.2 06/11/2005 01:10:00 3.3 0.6 4.6 1.5 3.2 0.6 4.6 1.1 1.9 0.8 4.2 0.4 65 13 47 255 12.3 0 12.2 12.2 06/11/2005 01:20:00 3.5 0.6 4.9 2.3 3.4 0.6 5.3 2.3 2.2 0.7 3.8 0.7 66 13 70 255 12.1 0 12.2 11.9 06/11/2005 01:30:00 3.4 0.6 4.9 2.3 3.4 0.6 4.9 2.3 2 0.7 3.8 0.4 73 10 77 255 11.7 0 11.9 11.7 06/11/2005 01:40:00 3.6 0.6 4.9 1.9 3.5 0.6 5.3 1.9 2.3 0.7 4.2 0.4 63 12 68 255 11.4 0 11.7 11.4 06/11/2005 01:50:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 1.1 1.4 0.7 3 0.4 61 13 64 255 11.2 0 11.4 11.1 06/11/2005 02:00:00 3.2 0.7 4.9 1.5 3.2 0.7 4.9 1.5 1.9 0.8 4.2 0.4 58 11 49 255 11.1 0 11.1 11.1 06/11/2005 02:10:00 3.7 0.7 5.7 1.9 3.6 0.8 6.1 1.5 2.2 0.9 5.3 0.4 65 13 58 255 11.1 0 11.1 11.1 06/11/2005 02:20:00 3.7 0.7 5.7 1.9 3.6 0.8 5.7 1.9 2.2 1 4.9 0.4 68 13 60 255 11.1 0 11.1 11.1 06/11/2005 02:30:00 3.3 0.7 4.9 1.1 3.2 0.7 4.9 1.5 1.9 0.9 3.8 0.4 67 13 62 255 11.1 0 11.1 11.1 06/11/2005 02:40:00 3.6 0.9 6.1 1.5 3.5 0.9 6.1 1.5 2.3 1 5.3 0.4 64 15 63 255 11.1 0 11.1 10.9 06/11/2005 02:50:00 4.4 0.9 6.5 1.5 4.3 0.9 6.5 1.9 3.1 0.9 5.3 0.7 61 13 72 255 11.1 0 11.1 11.1 06/11/2005 03:00:00 4.5 0.9 6.8 2.6 4.5 1 7.2 2.6 3.4 1.1 7.2 0.7 60 15 58 255 11.1 0 11.1 11.1 06/11/2005 03:10:00 4.8 0.9 7.6 2.3 4.8 0.9 7.6 2.6 3.4 1 6.1 1.1 44 16 45 255 10.8 0.1 11.1 10.6 06/11/2005 03:20:00 4.6 1.2 8 2.6 4.6 1.2 8.4 1.9 3.6 1.2 7.2 1.1 38 17 22 255 10.6 0 10.9 10.6 06/11/2005 03:30:00 4.5 0.9 6.5 2.3 4.4 1 6.8 2.3 3.5 1 6.1 1.5 49 21 37 255 10.6 0 10.6 10.6 06/11/2005 03:40:00 4.5 1.2 8.4 1.9 4.5 1.1 8 1.9 3.2 1.1 6.8 0.4 58 16 63 255 10.4 0 10.6 10.3 06/11/2005 03:50:00 4.6 1 7.2 1.9 4.5 1 6.8 2.3 3.5 1 6.5 1.5 50 15 58 255 10.2 0 10.3 10.3 06/11/2005 04:00:00 4.9 0.9 7.2 2.3 4.8 0.9 7.6 2.3 3.7 1.1 6.5 0.7 47 13 40 255 10.2 0 10.3 10.3 06/11/2005 04:10:00 4.3 0.8 6.5 1.9 4.3 0.8 6.8 2.3 3.4 0.8 5.7 1.5 58 13 59 255 10.2 0 10.3 10.1 06/11/2005 04:20:00 3.4 0.8 5.7 1.5 3.4 0.8 5.7 1.5 2.5 0.9 4.9 0.4 59 15 69 255 10 0 10.3 10.1 06/11/2005 04:30:00 3.4 0.7 5.3 1.9 3.4 0.8 5.3 1.9 2.4 0.8 4.6 0.4 64 15 71 255 10 0 10.1 9.8 06/11/2005 04:40:00 4.2 0.9 6.5 1.9 4.2 1 6.8 1.9 3.2 0.8 5.7 1.1 56 17 51 255 10 0 10.1 9.8 06/11/2005 04:50:00 4 1 6.5 1.9 3.9 1 6.5 1.9 2.9 1 5.3 0.4 52 14 50 255 9.8 0 10.1 9.8 06/11/2005 05:00:00 4.1 0.8 6.1 2.3 4.1 0.8 6.1 1.5 3 0.8 4.9 0.7 57 15 30 255 9.8 0 9.8 9.8 06/11/2005 05:10:00 4 0.9 6.1 2.3 3.9 0.9 6.1 1.5 2.9 0.8 5.3 0.7 66 14 63 255 9.8 0 9.8 9.6 06/11/2005 05:20:00 4.3 0.9 7.2 1.5 4.3 0.9 6.8 1.5 3.3 0.9 5.3 0.4 70 16 79 255 9.8 0 10.1 9.8 06/11/2005 05:30:00 5.1 1 7.2 2.6 5.1 1 7.6 2.6 3.8 1.1 6.5 1.1 72 15 59 255 10 0 10.1 9.8 06/11/2005 05:40:00 4.8 1 6.8 2.3 4.8 1 6.8 2.6 3.7 1 6.1 1.1 74 13 72 255 10.1 0 10.3 10.1 06/11/2005 05:50:00 4.6 0.9 7.2 2.6 4.5 1 7.2 1.9 3.5 0.9 6.1 1.5 67 15 54 255 10.1 0 10.3 10.1 06/11/2005 06:00:00 4.6 0.9 7.2 2.3 4.6 0.9 7.2 2.3 3.3 1 5.7 0.4 75 13 70 255 10.1 0 10.3 10.1 06/11/2005 06:10:00 4.3 1 6.8 2.3 4.3 1 6.8 1.9 3.1 1 5.3 0.7 74 14 52 255 10.1 0 10.3 10.1 06/11/2005 06:20:00 4.3 0.9 6.8 2.3 4.2 1 7.2 1.5 3.2 1.1 6.1 0.4 68 13 67 255 10.2 0 10.3 10.1 06/11/2005 06:30:00 4.3 0.9 6.5 2.3 4.3 1 6.8 2.3 3.2 1 5.7 0.4 67 13 62 255 10.2 0 10.3 10.1 06/11/2005 06:40:00 3.7 1 6.1 1.9 3.6 1 6.5 1.1 2.5 1 4.9 0.4 73 17 55 255 10.2 0 10.3 10.3 06/11/2005 06:50:00 4 0.8 5.7 2.3 3.9 0.8 6.1 1.9 3 0.8 5.3 1.1 63 13 67 255 10.2 0 10.3 10.3 06/11/2005 07:00:00 4.1 0.7 6.1 2.3 4.1 0.8 6.1 2.3 3 0.9 4.9 0.4 63 13 83 255 10.3 0 10.6 10.3 06/11/2005 07:10:00 4.2 0.7 5.7 2.6 4.1 0.7 5.7 2.3 3.1 0.8 5.3 0.7 70 15 50 255 10.3 0 10.6 10.3 06/11/2005 07:20:00 3.4 0.6 4.9 1.9 3.3 0.7 4.6 1.5 2.2 0.8 4.2 0.4 78 14 62 255 10.5 0 10.6 10.3 06/11/2005 07:30:00 3.4 0.6 4.6 1.1 3.3 0.7 4.6 1.1 2.3 0.8 4.2 0.4 84 9 71 255 10.6 0 10.6 10.6 06/11/2005 07:40:00 3.4 0.5 4.9 1.9 3.3 0.5 4.6 1.9 2.4 0.6 3.8 0.4 94 9 98 255 10.6 0 10.9 10.6 06/11/2005 07:50:00 3 0.5 4.2 1.5 2.8 0.5 4.6 1.1 2 0.6 3.8 0.4 86 14 105 255 10.9 0 11.1 10.6 06/11/2005 08:00:00 3.2 0.7 4.9 1.1 3.1 0.8 4.6 1.5 2.3 0.9 4.2 0.4 79 13 74 255 11.3 0 11.7 11.1 06/11/2005 08:10:00 3.8 0.7 5.7 1.9 3.7 0.7 5.7 1.5 2.9 0.9 5.3 0.4 91 15 89 255 11.5 0 11.7 11.4 06/11/2005 08:20:00 4.1 0.7 6.1 1.9 3.9 0.8 6.1 1.9 3.1 0.9 5.3 0.7 104 12 111 255 11.3 0 11.4 11.4 06/11/2005 08:30:00 3.5 0.7 5.7 1.5 3.4 0.7 5.7 1.5 2.5 0.9 4.6 0.4 95 16 104 255 11.6 0 11.9 11.4 06/11/2005 08:40:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 1.9 2.7 0.9 4.9 0.4 92 12 91 255 12.1 0 12.2 11.7 06/11/2005 08:50:00 3.6 0.7 5.3 1.9 3.6 0.7 5.3 1.9 2.6 0.8 4.6 0.4 84 15 68 255 12.5 0 12.7 12.2 06/11/2005 09:00:00 3.3 0.8 4.9 1.1 3.3 0.9 4.9 0.7 2.7 0.9 4.6 0.7 77 14 87 255 12.9 0 13.3 12.7 06/11/2005 09:10:00 3.6 0.8 5.7 1.5 3.5 0.8 5.7 1.9 2.8 0.9 4.9 0.4 75 13 67 255 13.1 0 13.3 13 06/11/2005 09:20:00 3 0.6 4.6 0.4 2.9 0.6 4.2 0.4 2.2 0.7 3.8 0.4 85 19 83 255 13.5 0.1 14.4 13.3 06/11/2005 09:30:00 2.9 0.7 4.6 1.1 2.9 0.7 4.6 1.1 2.3 0.7 3.8 0.4 87 17 97 255 13.9 0.1 14.6 13.5 06/11/2005 09:40:00 2.9 0.8 5.3 1.1 2.8 0.8 5.3 0.7 2.2 0.9 4.6 0.4 89 19 96 255 14.4 0.2 15.2 14.1 06/11/2005 09:50:00 3.8 0.8 6.5 1.1 3.8 0.8 6.1 1.5 3.3 0.7 4.9 1.5 95 17 106 255 15.1 0.2 15.7 14.6 06/11/2005 10:00:00 3.2 0.9 5.7 0.7 3.1 1 5.7 0.4 2.7 1 4.9 0.4 88 19 96 255 16.1 0.3 16.8 15.7 06/11/2005 10:10:00 3.6 0.8 4.9 0.7 3.5 0.8 5.3 0.4 3 0.9 5.3 0.4 97 27 90 255 16.5 0.1 17.1 16.3 06/11/2005 10:20:00 3.4 0.8 5.3 0.7 3.4 0.8 5.3 0.7 2.9 0.7 4.6 1.1 81 14 66 255 16.5 0.3 17.1 16.3 06/11/2005 10:30:00 2.7 1 4.9 0.4 2.6 1 4.9 0.4 2.2 1.1 4.9 0.4 74 35 93 255 17.2 0.3 18 16.8 06/11/2005 10:40:00 4.3 1 7.6 1.9 4.3 1 7.6 1.1 3.7 1 7.2 1.5 45 20 32 255 17 0.2 17.4 16.6 06/11/2005 10:50:00 4.5 1.1 7.6 1.9 4.5 1.2 8 1.9 3.8 1.1 6.8 0.7 52 18 47 255 17.2 0 17.4 16.8 06/11/2005 11:00:00 3.8 0.7 5.3 1.9 3.8 0.7 5.7 1.9 3.2 0.7 5.7 1.5 55 20 115 255 17 0.1 17.1 16.8 06/11/2005 11:10:00 3.9 0.9 6.1 1.5 3.9 1 6.5 1.5 3.2 1.1 6.1 0.7 57 21 60 255 17.8 0.4 18.8 17.1 06/11/2005 11:20:00 4.9 1.2 8 1.5 4.9 1.3 7.6 0.7 4.2 1.2 7.2 1.1 46 15 46 255 18.3 0 18.8 18.2 06/11/2005 11:30:00 4.5 2 9.1 0.4 4.4 2.1 9.1 0.4 3.9 1.8 8 0.4 42 23 22 255 18.4 0 18.8 18.2 06/11/2005 11:40:00 5.7 1.2 9.1 2.6 5.7 1.2 9.1 3 4.7 1.3 8 1.1 34 20 26 255 18.7 0.2 19.1 18.2 06/11/2005 11:50:00 6.4 1.2 9.9 3.8 6.4 1.3 9.9 3 5.3 1.3 8.8 2.6 31 18 37 255 18.7 0 19.4 18.5 06/11/2005 12:00:00 6.4 1.7 9.9 1.5 6.4 1.7 9.9 2.6 5.4 1.7 9.5 1.9 43 18 42 255 18.6 0.1 19.1 18.2 06/11/2005 12:10:00 6.9 1.3 10.3 3.4 6.9 1.4 9.9 2.6 5.7 1.3 8.8 1.9 36 16 28 255 19 0.1 19.7 18.5 06/11/2005 12:20:00 8 1 10.3 4.2 8 1 10.3 3.8 6.9 1.1 9.5 4.2 35 12 32 255 18 0.4 19.1 17.4 06/11/2005 12:30:00 7 1.4 11.1 3.4 7 1.5 11.1 3.8 5.8 1.5 9.5 1.9 31 15 14 255 17.8 0 18.2 17.4 06/11/2005 12:40:00 6.4 1.4 9.9 2.6 6.4 1.5 10.3 2.3 5.3 1.3 9.1 1.9 47 20 60 255 17.5 0.2 18.2 17.4 06/11/2005 12:50:00 7.1 1.4 10.3 4.2 7 1.5 10.3 3.8 5.8 1.5 9.5 2.3 37 15 34 255 17.8 0 18.2 17.4 06/11/2005 13:00:00 7.6 1.7 11.5 3 7.6 1.7 11.1 2.6 6.2 2.1 10.3 1.1 24 13 40 255 17.7 0 18.2 17.4 06/11/2005 13:10:00 7.2 1.1 10.3 3.8 7.2 1.1 10.7 3.8 5.6 1.5 9.9 1.9 17 12 7 255 18.2 0.1 18.8 17.7 06/11/2005 13:20:00 7.2 1.5 10.7 2.6 7.1 1.5 10.7 3 5.6 1.6 9.9 0.7 18 18 29 255 17.8 0.1 18.5 17.4 06/11/2005 13:30:00 7.7 1.5 12.2 4.2 7.6 1.5 12.6 3.8 6.3 1.6 11.1 2.3 26 15 17 255 17.5 0 17.7 17.4 06/11/2005 13:40:00 7.9 1.5 11.5 4.2 7.9 1.6 11.5 4.2 6.1 1.9 10.7 1.9 21 14 12 255 17.5 0 17.7 17.1 06/11/2005 13:50:00 7.3 1.5 11.8 3.8 7.3 1.5 11.5 4.2 6 1.7 10.7 2.3 21 13 28 255 17.8 0.1 18.2 17.4 06/11/2005 14:00:00 7 1.7 11.1 3.8 6.9 1.7 11.1 3 5.7 1.7 10.7 1.9 22 15 12 255 17.9 0 18.2 17.7 06/11/2005 14:10:00 7 1.1 9.5 3 7 1.1 9.5 3 5.4 1.4 9.1 2.3 22 13 31 255 18.1 0.3 18.5 17.7 06/11/2005 14:20:00 8.4 1.5 11.8 3.8 8.4 1.5 12.2 4.2 6.5 1.4 9.9 2.6 22 15 355 255 19 0.6 20.3 18.2 06/11/2005 14:30:00 8.3 1.7 14.1 4.6 8.2 1.7 14.5 4.2 7 1.7 13.3 3.4 36 14 32 255 19.8 0.2 20.3 19.4 06/11/2005 14:40:00 7.9 1.5 12.2 3.8 7.9 1.4 11.8 4.2 6.6 1.7 12.2 2.6 32 15 60 255 20 0.2 20.5 19.4 06/11/2005 14:50:00 7.4 1.4 11.8 4.2 7.4 1.4 11.5 4.6 6.1 1.4 10.3 2.6 27 14 32 255 19.7 0.4 20.8 19.1 06/11/2005 15:00:00 6.8 1.5 11.1 3.8 6.8 1.6 11.1 3 5.6 1.6 10.3 2.3 38 17 23 255 19 0 19.7 18.5 06/11/2005 15:10:00 6.9 1.4 10.7 3.4 6.8 1.4 10.3 3.4 5.9 1.4 10.3 2.6 38 16 45 255 19.4 0.2 20.3 19.1 06/11/2005 15:20:00 7.1 1.3 10.3 3.8 7.1 1.3 9.9 3.8 5.9 1.5 9.1 2.3 46 16 81 255 20.3 0.1 20.8 20 06/11/2005 15:30:00 6.6 1.3 9.9 3.8 6.5 1.3 9.9 3.4 5.6 1.5 9.5 2.3 31 17 49 255 21.1 0.2 21.7 20.8 06/11/2005 15:40:00 6.8 1.2 10.7 3.8 6.7 1.3 10.7 3.4 5.7 1.3 8.8 2.6 33 15 39 255 21.2 0 21.7 21.1 06/11/2005 15:50:00 6.3 1.5 9.9 3 6.3 1.5 9.9 3.4 5.3 1.5 9.5 1.5 41 17 33 255 20.6 0.3 21.1 20.3 06/11/2005 16:00:00 6.1 1.4 9.1 2.3 6 1.4 9.5 2.6 5.2 1.5 8.4 1.5 35 21 19 255 20.8 0.3 21.4 20.3 06/11/2005 16:10:00 5.6 1.1 9.5 3.4 5.6 1.1 9.5 3 4.2 1.2 8 1.5 25 19 53 255 20.5 0.2 20.8 20 06/11/2005 16:20:00 6.4 1.3 10.3 3.4 6.3 1.3 9.9 3 5 1.5 9.5 1.5 23 16 17 255 21 0 21.1 20.8 06/11/2005 16:30:00 6.6 1.1 9.9 3.8 6.6 1.1 9.9 4.2 5.2 1.4 9.1 1.9 29 15 37 255 20.6 0.1 21.4 20.5 06/11/2005 16:40:00 6.4 1.1 10.3 3 6.4 1.2 10.7 3 5.3 1.3 9.1 1.9 35 18 49 255 19.5 0.7 21.1 18.5 06/11/2005 16:50:00 6.2 1 8.8 2.6 6.2 1.1 8.8 2.6 5.3 1.3 8.8 2.3 38 14 63 255 18.9 0.3 19.4 18.2 06/11/2005 17:00:00 6 1.1 8.8 3.4 5.9 1.1 8.4 3.4 4.9 1.3 8.4 1.1 36 15 25 255 18.8 0.4 20 18.2 06/11/2005 17:10:00 6.9 1.5 11.1 3 6.9 1.5 10.7 3 5.3 1.7 8.8 1.5 21 15 26 255 19.9 0 20.5 19.4 06/11/2005 17:20:00 7 1.3 10.3 4.2 6.9 1.3 10.3 4.2 5.7 1.5 9.1 2.3 26 16 27 255 19.7 0.3 20.5 19.1 06/11/2005 17:30:00 6.6 1.3 9.9 3.8 6.5 1.3 9.5 3 5.2 1.4 9.1 2.3 30 15 38 255 19.4 0.1 20 19.1 06/11/2005 17:40:00 6.4 1.3 10.7 3.4 6.4 1.3 11.1 3.4 5.6 1.4 9.5 2.3 35 13 40 255 19.7 0 20.3 19.4 06/11/2005 17:50:00 6.5 1.5 10.7 3.4 6.5 1.5 10.3 3.4 5.4 1.6 9.5 2.3 30 16 19 255 19.4 0.2 20 18.8 06/11/2005 18:00:00 7 1.5 10.7 3.8 7 1.5 10.7 4.2 6 1.5 9.9 2.3 29 14 27 255 18.3 0.2 19.1 17.7 06/11/2005 18:10:00 6.4 1.5 10.3 2.6 6.4 1.5 11.1 2.3 5 1.7 8.4 1.1 30 17 19 255 17.8 0 18.2 17.4 06/11/2005 18:20:00 7.5 1.2 11.5 3.8 7.4 1.2 11.8 4.2 6.5 1.4 9.9 2.3 29 14 71 255 17.8 0 18 17.7 06/11/2005 18:30:00 6.8 1.3 11.5 3.8 6.8 1.3 11.1 3.4 5.4 1.6 9.9 1.9 29 15 18 255 17.9 0 18 17.7 06/11/2005 18:40:00 6.8 1.5 10.3 2.3 6.8 1.5 10.3 2.3 5.6 1.7 9.5 1.9 23 16 33 255 17.8 0 18 17.4 06/11/2005 18:50:00 6.8 1.3 11.5 3.8 6.8 1.3 11.1 3.8 5.6 1.3 10.3 2.6 32 15 26 255 17.3 0 17.7 17.1 06/11/2005 19:00:00 6.8 1.7 11.1 3 6.8 1.7 10.7 2.6 5.5 1.8 10.7 1.5 29 15 21 255 17.1 0 17.1 16.8 06/11/2005 19:10:00 7.1 1.5 10.3 3.4 7 1.5 10.3 3.4 5.6 1.6 9.5 1.5 25 16 12 255 16.7 0 16.8 16.6 06/11/2005 19:20:00 6.9 1.3 10.3 3 6.9 1.3 9.9 3.4 5.9 1.3 9.1 3 26 12 356 255 16.7 0 16.8 16.6 06/11/2005 19:30:00 6.7 1.1 9.9 3.4 6.7 1.2 10.3 3 5.8 1.1 8.8 2.6 29 14 37 255 16.6 0 16.8 16.6 06/11/2005 19:40:00 7.1 1.5 11.5 4.6 7 1.5 11.5 4.2 5.6 1.7 11.1 1.5 22 13 16 255 16.4 0.1 16.8 16.3 06/11/2005 19:50:00 7.3 1.3 11.1 4.2 7.3 1.3 11.1 3.8 5.9 1.6 9.9 1.9 24 13 6 255 16.1 0 16.3 16 06/11/2005 20:00:00 7 1.8 11.8 3 6.9 1.8 11.5 2.6 5.4 1.7 9.9 2.3 22 14 26 255 15.8 0 16.3 15.7 06/11/2005 20:10:00 6.4 1.3 10.3 3.4 6.4 1.3 10.7 3 5 1.4 8.4 1.5 23 13 37 255 15.4 0 16.3 15.2 06/11/2005 20:20:00 6 1.7 10.3 2.6 5.9 1.7 10.3 2.6 4.7 1.8 9.9 0.4 23 16 14 255 15.2 0.2 15.7 15.2 06/11/2005 20:30:00 6.1 1.1 9.1 3.8 6.1 1.1 9.5 3.8 4.7 1.5 8.8 1.1 24 15 12 255 15 0 15.5 14.9 06/11/2005 20:40:00 5.7 1.2 9.1 1.9 5.7 1.3 9.1 1.5 4.4 1.4 7.6 0.4 16 13 18 255 14.8 0.2 15.5 14.6 06/11/2005 20:50:00 4.6 1.3 8 1.5 4.5 1.3 8 1.5 3 1.3 8 0.7 357 17 15 255 14.3 0.2 15.2 14.1 06/11/2005 21:00:00 5.5 1.4 9.1 2.6 5.5 1.4 9.1 3 3.9 1.4 7.6 1.1 13 13 16 255 14.3 0 14.9 14.1 06/11/2005 21:10:00 3.8 1 6.5 0.7 3.7 1.1 6.1 1.1 2.3 1.1 5.3 0.4 6 21 28 255 14.2 0.2 14.9 13.8 06/11/2005 21:20:00 4.3 1 6.8 2.3 4.2 1 6.5 1.9 3.2 1.2 5.7 0.7 13 18 21 255 14 0.1 14.6 13.8 06/11/2005 21:30:00 2.7 0.8 4.6 0.4 2.6 0.9 4.6 0.4 1.8 0.9 4.2 0.4 2 20 358 255 13.7 0.1 14.1 13.3 06/11/2005 21:40:00 2.8 0.8 5.3 1.1 2.7 0.9 5.7 0.7 1.8 0.8 4.2 0.4 359 9 348 255 13.3 0 13.5 13 06/11/2005 21:50:00 2.1 0.5 3 0.7 1.8 0.6 3 0.4 1.4 0.5 2.6 0.4 352 17 327 255 12.8 0 13.3 12.5 06/11/2005 22:00:00 2.3 0.8 3.8 0.4 2.1 0.8 4.2 0.4 1.5 0.7 3.8 0.4 32 17 36 255 12.5 0 13 12.2 06/11/2005 22:10:00 2.2 0.7 4.2 0.7 2.1 0.8 3.8 0.4 1.5 0.7 3.8 0.4 21 15 42 255 11.8 0.2 12.7 11.7 06/11/2005 22:20:00 1.9 0.4 3 1.1 1.7 0.5 3 0.7 1.2 0.4 3 0.4 41 12 53 255 11.4 0.1 11.7 11.1 06/11/2005 22:30:00 2.9 0.6 4.6 1.1 2.7 0.6 4.2 1.1 2 0.6 3.8 0.7 30 30 39 255 11.3 0 11.7 11.1 06/11/2005 22:40:00 2.7 0.6 4.6 1.1 2.6 0.7 4.6 1.1 1.7 0.6 3 0.4 30 23 37 255 11.3 0.1 11.7 11.1 06/11/2005 22:50:00 2 0.6 4.6 0.7 1.9 0.6 4.2 0.7 1.1 0.6 2.6 0.4 52 18 28 255 11.8 0.1 11.9 11.7 06/11/2005 23:00:00 2.1 0.8 4.2 0.4 1.9 0.9 4.2 0.4 1.1 0.8 3.4 0.4 25 15 39 255 11.3 0 11.7 11.1 06/11/2005 23:10:00 3.1 0.4 4.2 2.6 3 0.4 4.6 2.3 2.4 0.4 3.8 1.5 32 6 37 255 11.2 0 11.4 11.1 06/11/2005 23:20:00 3.3 0.7 4.9 1.1 3.1 0.7 5.3 1.1 2.3 0.6 4.6 0.7 41 11 64 255 11.5 0.2 11.7 11.1 06/11/2005 23:30:00 2.6 0.6 4.6 0.7 2.5 0.7 4.6 1.1 1.7 0.8 4.2 0.4 49 15 30 255 10.9 0.3 11.7 10.6 06/11/2005 23:40:00 2.5 0.5 3.8 0.7 2.3 0.5 3.8 0.7 1.8 0.5 3 0.4 53 12 39 255 10.5 0 10.6 10.3 06/11/2005 23:50:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 0.7 1.6 0.5 2.6 0.4 70 12 70 255 10.4 0.2 10.9 9.8 06/12/2005 00:00:00 2.2 0.3 3 1.1 2 0.3 3 1.1 1.3 0.4 2.3 0.4 88 9 92 255 9.6 0 10.1 9.6 06/12/2005 00:10:00 1.9 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1.2 0.3 1.9 0.4 72 11 62 255 9.2 0.1 9.6 9 06/12/2005 00:20:00 1.8 0.3 3 1.1 1.7 0.4 2.6 0.4 1.2 0.3 1.9 0.4 82 15 71 255 8.8 0 9.3 8.5 06/12/2005 00:30:00 2 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.3 0.3 2.3 0.4 99 9 103 255 8.5 0 8.8 8.5 06/12/2005 00:40:00 2.2 0.3 2.6 1.5 2.1 0.3 2.6 1.1 1.4 0.3 2.3 0.7 86 8 94 255 8.3 0 8.5 8.3 06/12/2005 00:50:00 2 0.4 3 0.7 1.8 0.4 3 0.4 1.5 0.3 2.3 0.7 115 11 99 255 8.3 0 8.5 8.3 06/12/2005 01:00:00 2.5 0.3 3.4 1.9 2.4 0.3 3 1.5 1.6 0.4 2.3 0.7 95 10 109 255 8.3 0 8.5 8.3 06/12/2005 01:10:00 2 0.4 3 0.7 1.8 0.5 2.6 0.4 1.2 0.4 2.3 0.4 100 11 105 255 8.5 0.1 8.8 8.3 06/12/2005 01:20:00 2.1 0.4 3 0.7 1.9 0.4 2.6 0.4 1.3 0.4 2.3 0.4 101 10 98 255 8.7 0 8.8 8.5 06/12/2005 01:30:00 1.8 0.5 2.6 0.7 1.6 0.5 2.6 0.4 1 0.4 1.9 0.4 115 16 89 255 8.9 0 9 8.8 06/12/2005 01:40:00 2 0.4 2.6 0.7 1.9 0.5 2.6 0.4 1.9 0.6 3 0.4 130 9 133 255 9.1 0.2 9.6 9 06/12/2005 01:50:00 1.9 0.4 3 0.7 1.7 0.4 2.6 0.4 1.5 0.4 2.3 0.7 125 9 124 255 9.5 0 9.8 9.6 06/12/2005 02:00:00 1.6 0.4 2.6 0.7 1.3 0.5 2.6 0.4 1.2 0.6 2.6 0.4 116 13 108 255 9.8 0 9.8 9.6 06/12/2005 02:10:00 2 0.4 3 0.7 1.9 0.4 3 1.1 1.6 0.6 3.4 0.4 125 12 122 255 9.8 0 9.8 9.6 06/12/2005 02:20:00 2.1 0.4 2.6 1.1 2 0.4 2.6 0.7 1.7 0.5 3 0.4 141 9 129 255 10.1 0.1 10.3 9.6 06/12/2005 02:30:00 1.4 0.4 2.6 0.4 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 116 9 119 255 10 0 10.3 9.8 06/12/2005 02:40:00 1.8 0.3 2.6 1.1 1.6 0.4 2.6 0.7 0.8 0.4 1.5 0.4 105 3 110 255 10 0 10.1 9.8 06/12/2005 02:50:00 1.5 0.3 2.6 0.7 1.3 0.4 2.6 0.4 0.7 0.3 1.1 0.4 80 19 83 255 10 0 10.1 9.8 06/12/2005 03:00:00 1.6 0.4 2.3 0.7 1.3 0.4 2.3 0.4 0.8 0.3 1.5 0.4 75 15 89 255 10 0 10.1 9.8 06/12/2005 03:10:00 1.8 0.4 2.6 0.7 1.6 0.5 3 0.4 0.9 0.4 2.3 0.4 80 10 89 255 10 0 10.1 9.8 06/12/2005 03:20:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.5 1.9 0.4 81 10 76 255 9.9 0 10.1 9.8 06/12/2005 03:30:00 1.8 0.6 3 0.7 1.6 0.7 3 0.4 1.1 0.5 1.9 0.4 64 6 64 255 10.2 0 10.3 10.1 06/12/2005 03:40:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 1.9 0.4 69 9 76 255 10.1 0 10.3 9.8 06/12/2005 03:50:00 1.7 0.4 2.6 1.1 1.5 0.4 3 0.4 1 0.4 2.3 0.4 80 8 77 255 10.1 0 10.3 10.1 06/12/2005 04:00:00 1.5 0.5 3 0.7 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 61 8 77 255 10.3 0 10.6 10.3 06/12/2005 04:10:00 1.8 0.5 2.6 0.7 1.6 0.5 3 0.4 1 0.4 2.3 0.4 73 6 73 255 10.3 0.1 10.6 10.1 06/12/2005 04:20:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 0.9 0.4 1.9 0.4 88 7 96 255 10.1 0 10.3 10.1 06/12/2005 04:30:00 1.9 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1.2 0.4 2.3 0.4 71 14 77 255 10.2 0 10.3 10.3 06/12/2005 04:40:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 1 0.6 2.3 0.4 80 9 85 255 10.5 0 10.6 10.3 06/12/2005 04:50:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 85 10 74 255 10.3 0.1 10.6 10.3 06/12/2005 05:00:00 2.1 0.4 3 1.1 1.9 0.4 3 1.1 1.4 0.4 2.6 0.4 80 15 84 255 10.1 0 10.3 10.1 06/12/2005 05:10:00 2 0.4 3 0.7 1.8 0.5 2.6 0.4 1.2 0.4 2.3 0.4 58 10 49 255 10.3 0 10.6 10.3 06/12/2005 05:20:00 1.8 0.3 2.6 0.7 1.6 0.4 2.6 0.7 1 0.5 2.3 0.4 66 9 60 255 10.5 0 10.6 10.3 06/12/2005 05:30:00 2.1 0.4 3 1.1 2 0.5 3.4 1.1 1.4 0.5 2.6 0.4 71 8 73 255 10.6 0 10.6 10.6 06/12/2005 05:40:00 2.2 0.8 3.4 0.4 2.1 0.8 3.4 0.4 1.6 0.7 2.6 0.4 65 10 71 255 10.5 0 10.6 10.3 06/12/2005 05:50:00 1.4 0.6 3 0.4 1.2 0.6 3 0.4 0.8 0.4 1.9 0.4 76 15 90 255 10.5 0 10.6 10.3 06/12/2005 06:00:00 2.4 0.5 3.4 1.1 2.2 0.5 3 0.7 1.5 0.5 2.6 0.4 108 12 107 255 10.3 0 10.6 10.3 06/12/2005 06:10:00 1.7 0.6 3 0.4 1.5 0.7 3 0.4 0.9 0.4 1.9 0.4 112 17 120 255 10.3 0 10.3 10.3 06/12/2005 06:20:00 2.6 0.4 3.8 1.5 2.5 0.4 3.4 1.5 1.5 0.4 2.6 0.4 83 8 78 255 10.3 0 10.3 10.3 06/12/2005 06:30:00 2.5 0.4 3.4 1.1 2.4 0.5 3.4 0.4 1.5 0.4 2.6 0.4 97 10 90 255 10.2 0 10.3 10.3 06/12/2005 06:40:00 2.7 0.4 3.8 1.1 2.7 0.5 3.8 0.7 1.8 0.5 2.6 0.4 94 7 84 255 10.2 0 10.3 10.3 06/12/2005 06:50:00 1.9 0.7 3 0.4 1.8 0.8 3.4 0.4 1.1 0.6 2.6 0.4 112 11 92 255 10.4 0 10.6 10.3 06/12/2005 07:00:00 2 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.3 0.6 3 0.4 120 11 119 255 10.5 0 10.6 10.3 06/12/2005 07:10:00 3 0.7 5.3 1.1 2.9 0.7 5.7 1.1 2.2 0.6 3.8 0.7 120 15 98 255 10.6 0 10.9 10.6 06/12/2005 07:20:00 3.6 0.9 5.7 1.1 3.6 0.9 5.7 1.1 2.7 0.9 4.9 0.7 113 17 109 255 10.8 0 10.9 10.6 06/12/2005 07:30:00 3.5 0.8 5.7 1.5 3.4 0.8 5.3 1.1 2.7 0.8 4.6 0.7 106 15 104 255 10.9 0 10.9 10.9 06/12/2005 07:40:00 4.2 0.9 6.5 1.9 4.1 0.9 6.1 1.9 3.2 0.8 5.3 1.5 106 13 94 255 10.9 0 11.1 10.9 06/12/2005 07:50:00 5.6 0.8 7.2 3 5.6 0.7 7.2 3.8 4.4 1 6.5 2.3 110 13 92 255 11 0 11.1 10.9 06/12/2005 08:00:00 3.9 0.8 6.1 1.9 3.8 0.8 6.1 1.5 3.1 0.8 5.3 1.1 107 13 106 255 11 0 11.1 10.9 06/12/2005 08:10:00 3.4 0.8 5.3 1.5 3.3 0.8 5.3 1.1 2.5 0.8 4.2 0.7 112 15 109 255 11.1 0 11.1 10.9 06/12/2005 08:20:00 3.7 0.8 5.3 1.5 3.6 0.8 5.3 1.1 2.8 0.8 4.6 0.4 109 15 130 255 11.2 0 11.4 11.1 06/12/2005 08:30:00 3.6 0.8 6.1 1.5 3.6 0.9 5.7 1.5 3 0.9 5.3 1.1 113 17 115 255 11.5 0 11.7 11.4 06/12/2005 08:40:00 4.8 1 6.8 1.9 4.7 0.9 7.2 2.3 3.9 1 5.7 1.1 110 14 124 255 11.8 0.1 12.2 11.7 06/12/2005 08:50:00 4 0.9 6.1 1.5 3.9 1 6.1 1.5 3.2 1 5.7 1.1 109 17 131 255 12.7 0.3 13.3 12.2 06/12/2005 09:00:00 4.4 0.7 6.5 2.6 4.3 0.7 6.1 2.6 4 0.7 5.7 1.9 100 11 98 255 13.7 0.1 13.8 13.3 06/12/2005 09:10:00 4.3 0.9 6.5 2.3 4.2 0.9 6.1 1.9 3.7 1 5.7 1.5 106 13 104 255 13.9 0 14.4 13.8 06/12/2005 09:20:00 4 0.9 6.1 1.5 3.9 0.9 6.1 1.5 3.4 0.9 5.7 0.7 104 16 104 255 14.1 0.1 14.6 13.8 06/12/2005 09:30:00 4 1.2 6.5 1.1 4 1.1 6.5 1.1 3.6 1 6.1 1.1 106 19 105 255 14.7 0.2 15.2 14.4 06/12/2005 09:40:00 3.4 1.1 6.5 0.7 3.4 1.1 6.1 0.7 2.8 1 5.7 0.7 101 22 118 255 15.4 0 16 15.2 06/12/2005 09:50:00 3.9 1 5.7 1.5 3.8 1 5.7 1.5 3.3 1 5.3 0.7 104 18 141 255 15.5 0 16 15.5 06/12/2005 10:00:00 4.1 0.7 5.3 1.9 4.1 0.6 5.3 1.9 3.6 0.8 5.7 1.5 94 9 97 255 16.5 0.3 16.8 16 06/12/2005 10:10:00 3.4 0.9 6.1 1.1 3.3 1 5.3 0.4 3 1 5.3 0.4 93 17 78 255 17.1 0 17.4 16.8 06/12/2005 10:20:00 2.9 1 4.9 0.4 2.9 1 5.3 0.4 2.7 0.9 4.6 0.4 104 26 105 255 17.2 0 17.7 16.8 06/12/2005 10:30:00 3.2 0.9 4.9 0.4 3.2 0.9 4.9 0.4 2.9 0.8 5.3 0.7 88 22 66 255 17.1 0.2 17.4 16.8 06/12/2005 10:40:00 2.8 0.8 4.6 0.7 2.8 0.7 4.6 0.7 2.3 0.8 5.3 0.7 97 24 80 255 17.4 0 17.7 17.1 06/12/2005 10:50:00 2.4 0.6 3.8 0.7 2.4 0.6 3.8 1.1 2.4 0.6 3.8 0.7 126 23 138 255 17.1 0.3 17.7 16.8 06/12/2005 11:00:00 2.7 0.7 3.8 0.4 2.7 0.6 3.8 0.7 2.5 0.7 4.2 0.4 139 17 136 255 16.8 0 17.1 16.6 06/12/2005 11:10:00 2.5 0.6 3.8 0.7 2.6 0.6 3.8 0.7 2.2 0.9 3.8 0.4 130 15 142 255 16.9 0 17.1 16.6 06/12/2005 11:20:00 2.3 0.7 3.8 0.4 2.3 0.8 3.8 0.4 2.2 0.7 3.8 0.4 124 27 112 255 17.6 0 18 17.1 06/12/2005 11:30:00 1.7 0.6 3 0.4 1.7 0.6 2.6 0.4 1.6 0.7 3 0.4 162 26 151 255 17.9 0 18.2 17.7 06/12/2005 11:40:00 1.5 0.7 3.4 0.4 1.5 0.7 3 0.4 1.2 0.6 3 0.4 166 49 249 255 18.3 0.3 19.4 17.7 06/12/2005 11:50:00 1.5 0.7 3.8 0.4 1.6 0.8 4.2 0.4 1.4 0.6 3.8 0.4 172 49 215 255 19.5 0.1 20.3 19.1 06/12/2005 12:00:00 2.3 0.7 3.8 0.4 2.3 0.7 4.2 0.4 2 0.7 4.2 0.4 205 27 196 255 20.6 0.9 22.3 19.1 06/12/2005 12:10:00 1.5 0.5 3 0.4 1.5 0.5 3 0.4 1.2 0.5 2.3 0.4 220 19 212 255 21.1 0.5 22.3 20.5 06/12/2005 12:20:00 1.5 0.7 3 0.4 1.5 0.8 3.4 0.4 1.4 0.7 3 0.4 189 35 173 255 20.7 0.6 21.7 20 06/12/2005 12:30:00 1.2 0.6 3 0.4 1.2 0.6 3 0.4 1.4 0.7 3.8 0.4 116 56 136 255 20.6 0.4 21.4 20 06/12/2005 12:40:00 2.5 1 4.6 0.4 2.5 0.9 4.2 0.4 2.3 1 4.6 0.4 215 51 238 255 20.8 0.1 21.1 20.3 06/12/2005 12:50:00 2 1 4.9 0.4 2 1 4.9 0.4 2 0.9 4.6 0.4 213 43 238 255 20.7 0.2 21.1 20.3 06/12/2005 13:00:00 2.7 0.9 4.9 0.4 2.7 0.9 4.9 0.4 2.4 0.9 4.2 0.4 219 22 218 255 20.3 0 20.8 20.3 06/12/2005 13:10:00 1.7 1 3.8 0.4 1.6 1 3.8 0.4 1.4 1 4.2 0.4 250 90 192 255 20.7 0.2 21.7 20.5 06/12/2005 13:20:00 2.1 0.9 4.2 0.4 2.1 0.8 3.8 0.4 1.8 0.8 3.8 0.4 230 47 300 255 21.6 0.2 22.3 21.1 06/12/2005 13:30:00 2.2 0.8 4.6 0.4 2.2 0.8 4.2 0.4 1.8 0.8 3.8 0.4 225 56 200 255 21.9 0.3 22.3 21.1 06/12/2005 13:40:00 1.9 0.7 4.2 0.4 2 0.8 3.8 0.4 1.8 0.6 3.4 0.4 177 28 220 255 21.3 0.2 22 21.1 06/12/2005 13:50:00 1.8 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.3 0.8 3.8 0.4 209 53 215 255 21.7 0.2 22.3 21.4 06/12/2005 14:00:00 2.3 0.9 4.9 0.4 2.4 0.9 4.9 0.4 2.2 0.9 4.9 0.7 239 49 200 255 21.9 0.2 22.6 21.1 06/12/2005 14:10:00 1.8 1 4.2 0.4 1.9 1 4.2 0.4 1.6 0.9 3.8 0.4 202 38 192 255 21.6 0.4 22.6 21.1 06/12/2005 14:20:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 181 58 115 255 22.2 0.2 22.9 21.7 06/12/2005 14:30:00 2.3 1 4.6 0.4 2.3 1 4.6 0.4 2 1 4.6 0.4 260 35 253 255 22.7 0.2 23.5 22.3 06/12/2005 14:40:00 2.6 0.9 4.9 0.4 2.7 0.9 4.9 0.4 2.3 0.9 4.9 0.4 253 32 205 255 22.4 0 22.9 22 06/12/2005 14:50:00 2.8 1 5.3 0.4 3 1 5.3 0.4 2.4 1 4.9 0.4 204 28 204 255 22.4 0.1 22.9 22 06/12/2005 15:00:00 2 0.6 3.8 0.7 2.1 0.7 3.8 0.7 2 0.7 3.8 0.7 173 23 198 255 21.2 0.7 22.3 20.3 06/12/2005 15:10:00 2.1 1 4.2 0.4 2.1 1 4.2 0.4 1.9 0.9 4.2 0.4 163 58 223 255 21.5 0.3 22 20.8 06/12/2005 15:20:00 2 0.9 4.6 0.4 2 0.9 4.2 0.4 1.7 0.9 4.2 0.4 210 39 223 255 22.4 0.4 23.5 21.7 06/12/2005 15:30:00 2.1 1.2 6.5 0.4 2.2 1.2 6.1 0.4 2 1 5.7 0.4 121 82 270 255 23 0.2 23.5 22.6 06/12/2005 15:40:00 3.2 1.5 5.7 0.4 3.2 1.5 6.1 0.4 2.7 1.4 5.3 0.4 293 36 269 255 22.7 0 22.9 22.6 06/12/2005 15:50:00 3.3 1.2 6.1 0.7 3.1 1.1 5.7 0.4 2.7 1.2 6.1 0.4 298 49 313 255 22.4 0.1 22.9 22.3 06/12/2005 16:00:00 3.1 0.9 5.7 1.1 3.1 1 6.1 0.4 2.6 1.1 6.5 0.4 279 33 269 255 22.7 0.1 22.9 22 06/12/2005 16:10:00 3.7 1.3 6.1 0.7 3.6 1.3 6.1 0.7 3.1 1.3 5.7 0.4 262 30 287 255 21.9 0 22.3 21.7 06/12/2005 16:20:00 2.8 1 5.3 0.7 2.8 1 4.9 0.4 2.3 1 4.6 0.4 279 32 310 255 22.1 0.1 22.3 21.7 06/12/2005 16:30:00 2.6 1 5.3 0.4 2.7 1.1 4.9 0.4 2.3 1.1 4.2 0.4 242 41 261 255 22.2 0 22.3 22 06/12/2005 16:40:00 3.3 1.3 6.5 0.4 3.3 1.4 6.5 0.4 2.8 1.3 6.1 0.4 269 33 304 255 22.1 0 22.3 21.7 06/12/2005 16:50:00 2 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.8 0.8 3.8 0.4 248 36 232 255 21.8 0 22 21.7 06/12/2005 17:00:00 2.4 1.5 5.3 0.4 2.4 1.5 5.7 0.4 1.8 1.2 4.9 0.4 238 49 233 255 21.8 0 22 21.7 06/12/2005 17:10:00 1.6 1 4.2 0.4 1.6 1 4.2 0.4 1.2 0.9 3.8 0.4 244 61 247 255 22.1 0 22.3 22 06/12/2005 17:20:00 2.8 1 5.3 0.4 2.8 1 5.3 0.4 2.4 0.8 4.9 0.4 246 30 225 255 21.9 0 22 21.7 06/12/2005 17:30:00 2.4 1 4.6 0.4 2.3 1 4.9 0.4 2 1 4.6 0.4 257 35 257 255 21.7 0 22 21.7 06/12/2005 17:40:00 2.4 1.1 5.3 0.4 2.4 1 5.3 0.4 2 1 4.9 0.4 285 43 279 255 21.6 0 22.3 21.4 06/12/2005 17:50:00 2.9 1.1 5.3 0.4 2.9 1.2 5.7 0.4 2.3 1.1 4.9 0.4 250 32 255 255 21.3 0.1 21.7 21.1 06/12/2005 18:00:00 2.2 1 4.6 0.4 2.3 1 4.6 0.4 2.2 0.8 4.9 0.4 258 64 243 255 21.6 0 22 21.1 06/12/2005 18:10:00 3.1 0.9 5.7 1.1 3 1 5.7 1.1 2.6 0.8 4.9 0.4 300 22 292 255 21.3 0 21.7 21.1 06/12/2005 18:20:00 4.3 1 6.8 1.1 4.2 1.1 7.2 0.4 3.4 1.2 6.8 0.7 302 22 282 255 21.1 0 21.1 20.8 06/12/2005 18:30:00 4.6 0.8 6.5 1.9 4.6 0.9 6.5 1.5 3.9 1 6.1 0.7 295 19 304 255 20.7 0.1 21.1 20.5 06/12/2005 18:40:00 3.8 1.1 6.1 1.1 3.8 1.1 6.5 1.1 3 1.2 5.7 0.7 298 19 316 255 20.3 0.1 20.8 20.3 06/12/2005 18:50:00 2.7 0.9 4.9 0.4 2.7 0.9 4.9 0.7 2.2 0.8 4.6 0.4 288 20 294 255 19.9 0 20.3 19.7 06/12/2005 19:00:00 2.8 1 5.7 0.7 2.8 1 6.1 0.4 1.9 0.9 4.9 0.4 287 20 253 255 19.5 0 19.7 19.1 06/12/2005 19:10:00 3 0.8 4.9 1.1 2.9 0.8 4.9 1.1 2.5 0.9 4.9 0.4 281 19 274 255 19.5 0.1 20 19.1 06/12/2005 19:20:00 3.4 0.8 5.3 1.5 3.4 0.9 5.7 1.1 2.7 0.9 5.3 0.7 294 17 296 255 19.5 0.1 20 19.4 06/12/2005 19:30:00 2.9 1 4.9 1.1 2.8 1 4.9 0.4 1.9 1 4.6 0.4 311 18 336 255 19.2 0.1 20 18.8 06/12/2005 19:40:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 2.7 0.8 4.9 0.7 295 15 265 255 18.8 0 19.4 18.5 06/12/2005 19:50:00 3 0.9 4.9 0.7 2.9 0.9 5.3 0.7 2.4 1 5.3 0.4 294 16 286 255 18.7 0 19.1 18.5 06/12/2005 20:00:00 2.9 0.8 4.9 1.1 2.9 0.8 4.9 1.1 2.3 1 4.6 0.4 298 17 300 255 18.7 0 19.1 18.5 06/12/2005 20:10:00 2.7 0.6 4.2 1.1 2.6 0.7 4.2 0.7 2.1 0.7 3.8 0.4 296 15 266 255 18.5 0.1 18.8 18.2 06/12/2005 20:20:00 2.9 0.6 4.6 1.5 3 0.6 4.6 1.5 2.3 0.8 4.2 0.4 293 15 306 255 18.4 0 18.5 18.2 06/12/2005 20:30:00 2.7 0.9 4.6 0.4 2.7 0.9 4.6 0.7 2.1 0.8 4.2 0.4 303 15 297 255 18.3 0 18.5 18.2 06/12/2005 20:40:00 2.4 0.5 3.8 1.1 2.3 0.5 3.4 1.1 1.7 0.7 3.4 0.4 314 15 314 255 18 0 18.2 17.7 06/12/2005 20:50:00 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 1.1 0.6 3 0.4 331 17 336 255 17.4 0.2 17.7 17.1 06/12/2005 21:00:00 2.3 0.5 3.8 0.7 2.1 0.5 3.4 0.7 1.3 0.7 3.4 0.4 351 15 332 255 16.8 0.1 17.1 16.6 06/12/2005 21:10:00 2.1 0.5 3 0.7 2 0.5 3 0.7 1.2 0.7 2.6 0.4 11 10 4 255 16.3 0.1 16.8 16.3 06/12/2005 21:20:00 3 0.5 4.2 1.1 3 0.5 4.2 1.1 2.4 0.7 3.8 0.7 22 8 26 255 16.1 0 16.6 16 06/12/2005 21:30:00 2.7 0.5 3.8 1.1 2.6 0.5 4.2 1.1 1.9 0.7 3.4 0.4 21 11 24 255 16 0 16.6 15.7 06/12/2005 21:40:00 2.6 0.7 3.8 0.4 2.6 0.7 3.8 0.7 1.9 0.8 3.4 0.4 21 9 27 255 15.7 0 16.3 15.5 06/12/2005 21:50:00 2.9 0.5 4.2 1.5 2.9 0.5 4.6 1.1 1.8 0.8 3.4 0.4 10 11 37 255 15.1 0.1 15.5 14.9 06/12/2005 22:00:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.4 0.6 3 0.4 15 12 26 255 14.6 0 15.2 14.4 06/12/2005 22:10:00 1.8 0.6 3.4 0.4 1.8 0.6 3 0.7 1 0.6 2.6 0.4 27 15 40 255 14.1 0.1 14.6 13.5 06/12/2005 22:20:00 1.5 0.5 3 0.4 1.5 0.5 3 0.4 0.8 0.5 2.6 0.4 47 16 48 255 13.4 0.2 14.1 12.7 06/12/2005 22:30:00 1.8 0.5 3 0.7 1.8 0.4 3 0.7 1.3 0.5 3 0.4 37 9 33 255 12.9 0 13.3 12.7 06/12/2005 22:40:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.9 0.4 1.9 0.4 43 13 35 255 12.7 0 13.3 12.5 06/12/2005 22:50:00 2.1 0.3 2.6 1.5 2.1 0.3 3 1.1 1.5 0.4 2.3 0.4 73 7 62 255 12.2 0 12.5 11.9 06/12/2005 23:00:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 1.6 0.4 2.6 0.7 62 5 75 255 11.9 0.1 12.5 11.7 06/12/2005 23:10:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.4 0.3 2.3 0.4 55 5 63 255 11.7 0 11.9 11.4 06/12/2005 23:20:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1 0.4 1.9 0.4 58 9 60 255 11.3 0 11.7 11.1 06/12/2005 23:30:00 1.6 0.3 2.6 0.7 1.5 0.4 2.6 0.7 0.9 0.4 1.9 0.4 67 12 66 255 11.1 0 11.7 10.9 06/12/2005 23:40:00 1.4 0.3 2.3 0.4 1.4 0.4 2.3 0.4 0.9 0.4 1.9 0.4 98 12 74 255 10.8 0 11.1 10.6 06/12/2005 23:50:00 1.8 0.3 2.3 1.1 1.7 0.3 2.3 1.1 0.7 0.3 1.5 0.4 90 10 82 255 10.5 0 11.1 10.3 06/13/2005 00:00:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 83 7 71 255 10.3 0.1 10.9 10.3 06/13/2005 00:10:00 1.7 1.5 6.8 0.4 1.7 1.5 6.1 0.4 1.3 1.2 4.9 0.4 314 94 265 255 10.2 0.1 10.6 10.1 06/13/2005 00:20:00 4 1.4 8.8 1.1 4 1.5 8.4 0.7 2.8 1.2 6.5 0.4 265 22 282 255 11.3 0.5 12.2 10.6 06/13/2005 00:30:00 4.4 1.5 8.8 1.5 4.4 1.5 8.8 1.1 3.1 1.2 6.8 0.7 264 24 268 255 12.9 0.2 13 12.2 06/13/2005 00:40:00 3.9 1.3 7.2 1.1 3.9 1.3 7.6 1.1 3 1.2 6.8 0.4 257 23 276 255 13 0 13.3 12.7 06/13/2005 00:50:00 3.4 1 6.5 1.1 3.4 1.1 6.5 0.7 2.6 1.1 5.3 0.4 257 22 266 255 12.8 0 13 12.7 06/13/2005 01:00:00 3.3 1.2 6.5 0.4 3.3 1.2 6.8 0.7 2.3 1.2 4.9 0.4 251 27 255 255 12.6 0 13 12.5 06/13/2005 01:10:00 2.6 1 6.8 0.7 2.7 1 7.2 0.4 1.8 1 6.5 0.4 232 30 239 255 12.5 0 13 12.5 06/13/2005 01:20:00 2.4 1 5.7 0.7 2.4 1 6.1 0.7 1.9 1 6.1 0.4 228 23 237 255 12.6 0 13 12.5 06/13/2005 01:30:00 2 1 4.2 0.4 2 1 4.6 0.4 1.4 0.9 4.6 0.4 220 22 216 255 12.7 0 13 12.5 06/13/2005 01:40:00 1.2 0.6 3.4 0.4 1.2 0.6 3 0.4 0.8 0.5 3 0.4 201 23 211 255 12.5 0.1 13 12.5 06/13/2005 01:50:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.3 0.7 3.4 0.4 221 21 246 255 12.4 0 12.5 12.2 06/13/2005 02:00:00 1.7 0.7 3.4 0.4 1.7 0.6 3 0.4 1.2 0.6 3 0.4 211 15 246 255 12.3 0 12.7 12.2 06/13/2005 02:10:00 1.5 0.6 3 0.4 1.6 0.6 3 0.4 1.2 0.5 3 0.4 195 22 203 255 12.2 0 12.2 11.9 06/13/2005 02:20:00 1 0.7 3 0.4 1 0.7 2.6 0.4 0.7 0.5 2.3 0.4 188 33 215 255 12.1 0 12.5 11.9 06/13/2005 02:30:00 1.2 0.4 2.6 0.4 1.6 0.5 3 0.4 1.2 0.5 2.6 0.4 175 6 165 255 11.7 0 11.9 11.4 06/13/2005 02:40:00 1.4 0.4 2.6 0.4 1.6 0.5 2.6 0.4 1.1 0.5 2.3 0.4 173 10 192 255 11.2 0 11.4 11.1 06/13/2005 02:50:00 1.6 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.1 0.5 2.3 0.4 155 12 151 255 10.9 0.1 11.1 10.6 06/13/2005 03:00:00 1.6 0.5 2.6 0.4 1.9 0.5 3 0.7 1.5 0.5 2.6 0.4 172 10 161 255 10.7 0 10.9 10.6 06/13/2005 03:10:00 1.5 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.3 0.3 1.9 0.4 165 11 198 255 10.6 0 10.6 10.6 06/13/2005 03:20:00 2.2 0.4 3 1.1 2.2 0.3 3 1.1 1.5 0.4 2.6 0.7 154 6 156 255 10.4 0 10.6 10.3 06/13/2005 03:30:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1 0.6 2.3 0.4 148 9 153 255 10.2 0 10.3 10.3 06/13/2005 03:40:00 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 0.9 0.4 1.9 0.4 125 6 122 255 10.1 0 10.3 10.1 06/13/2005 03:50:00 1.8 0.4 3 0.7 1.6 0.5 3 0.7 1.2 0.5 2.6 0.4 124 7 123 255 10 0 10.3 9.8 06/13/2005 04:00:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 1.4 0.5 2.6 0.4 125 10 122 255 10 0 10.1 9.8 06/13/2005 04:10:00 1.8 0.4 2.6 1.1 1.8 0.4 2.6 1.1 1.2 0.4 2.3 0.4 133 6 132 255 10.3 0 10.6 10.1 06/13/2005 04:20:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.1 0.3 1.9 0.4 144 3 143 255 10.2 0 10.6 10.3 06/13/2005 04:30:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1.4 0.4 2.3 0.4 148 5 151 255 10.2 0 10.3 10.3 06/13/2005 04:40:00 2.1 0.3 2.6 1.1 2.1 0.3 2.6 1.1 1.4 0.3 1.9 0.4 156 5 157 255 10.2 0 10.3 10.1 06/13/2005 04:50:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1.6 0.3 2.3 0.7 154 7 158 255 10.2 0 10.3 10.1 06/13/2005 05:00:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.2 0.4 2.3 0.4 139 9 133 255 10.2 0 10.3 10.1 06/13/2005 05:10:00 1.6 0.4 2.3 0.7 1.6 0.4 2.3 0.4 1.1 0.4 1.9 0.4 148 8 138 255 10.5 0 10.6 10.3 06/13/2005 05:20:00 1.7 0.4 2.3 0.4 1.7 0.4 2.6 0.4 1.2 0.4 1.9 0.4 150 9 153 255 10.6 0 10.9 10.6 06/13/2005 05:30:00 1.5 0.4 2.3 0.4 1.5 0.5 2.6 0.4 1.2 0.4 2.3 0.4 156 9 153 255 10.9 0 11.1 10.9 06/13/2005 05:40:00 1.9 0.3 2.6 0.7 1.9 0.3 2.6 0.7 1.4 0.4 2.6 0.7 152 6 150 255 11.1 0 11.1 11.1 06/13/2005 05:50:00 1.6 0.4 2.6 0.4 1.8 0.4 2.3 0.4 1.1 0.5 2.3 0.4 168 10 160 255 11.3 0 11.7 11.1 06/13/2005 06:00:00 1.6 0.5 3 0.4 1.8 0.4 3 0.7 1.2 0.5 2.3 0.4 187 10 208 255 11.5 0 11.7 11.4 06/13/2005 06:10:00 1.5 0.5 2.6 0.4 1.6 0.5 3 0.4 1 0.5 2.3 0.4 189 11 198 255 11.7 0 11.9 11.7 06/13/2005 06:20:00 1.7 0.5 2.6 0.7 2 0.4 3 0.7 1.1 0.4 2.3 0.4 186 12 207 255 11.9 0 12.2 11.9 06/13/2005 06:30:00 1.7 0.6 3.4 0.4 1.8 0.6 3.8 0.4 1.4 0.6 3.4 0.4 190 16 195 255 12.2 0 12.2 11.9 06/13/2005 06:40:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 189 17 195 255 12.3 0 12.5 12.2 06/13/2005 06:50:00 1.3 0.5 2.6 0.4 1.4 0.5 2.3 0.4 0.9 0.5 2.3 0.4 192 12 199 255 12.4 0 12.5 12.2 06/13/2005 07:00:00 1.5 0.7 3 0.4 1.7 0.7 3 0.4 1.3 0.6 3 0.4 188 13 192 255 12.5 0 12.5 12.5 06/13/2005 07:10:00 1.9 0.5 3 0.4 2.2 0.6 3.4 0.4 1.8 0.5 3 0.7 174 12 174 255 12.4 0 12.5 12.2 06/13/2005 07:20:00 1.8 0.5 3.4 0.4 2 0.6 3.4 0.7 1.7 0.5 3 0.7 166 16 170 255 12.3 0 12.5 12.2 06/13/2005 07:30:00 1.8 0.7 3.4 0.4 2.1 0.8 3.4 0.4 1.7 0.7 3.4 0.4 181 17 185 255 12.3 0 12.5 12.2 06/13/2005 07:40:00 2 0.6 3.4 0.4 2.2 0.7 3.8 0.4 1.8 0.6 3.8 0.4 170 22 184 255 12.3 0 12.5 12.2 06/13/2005 07:50:00 2 0.6 3.8 0.4 2.2 0.6 3.8 0.7 1.8 0.6 3.4 0.4 169 17 157 255 12.4 0 12.5 12.5 06/13/2005 08:00:00 1.8 0.6 3.4 0.4 2 0.6 3.8 0.4 1.6 0.6 3 0.4 169 15 169 255 12.4 0 12.5 12.5 06/13/2005 08:10:00 1.7 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 168 24 174 255 12.5 0 12.5 12.5 06/13/2005 08:20:00 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 3 0.4 175 20 192 255 12.5 0 13 12.5 06/13/2005 08:30:00 1.6 0.6 3 0.4 1.7 0.6 3 0.4 1.5 0.6 3 0.4 161 15 141 255 12.8 0 12.7 12.7 06/13/2005 08:40:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 160 28 164 255 12.9 0.1 13.5 12.7 06/13/2005 08:50:00 1.1 0.7 2.6 0.4 1.2 0.7 3 0.4 1.1 0.6 2.6 0.4 154 24 167 255 13.2 0.1 13.5 13 06/13/2005 09:00:00 1.7 0.4 2.6 0.4 1.8 0.4 2.6 0.7 1.7 0.5 2.6 0.4 162 10 163 255 13.1 0 13.8 13 06/13/2005 09:10:00 1.3 0.5 2.6 0.4 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 191 29 256 255 13.2 0 13.8 13 06/13/2005 09:20:00 1.2 0.5 2.6 0.4 1.3 0.5 3 0.4 1.2 0.5 2.6 0.4 175 22 196 255 13.3 0 13.8 13 06/13/2005 09:30:00 1.6 0.5 3 0.4 1.6 0.5 3.4 0.4 1.5 0.6 2.6 0.4 179 29 216 255 13.5 0.1 14.1 13.3 06/13/2005 09:40:00 1.4 0.6 3 0.4 1.4 0.7 2.6 0.4 1.3 0.6 2.6 0.4 210 61 164 255 14.4 0.5 15.5 13.8 06/13/2005 09:50:00 1.9 1 3.8 0.4 1.9 1 3.8 0.4 1.5 0.7 3.8 0.4 221 36 232 255 14.8 0.1 15.5 14.6 06/13/2005 10:00:00 1.3 0.9 3.4 0.4 1.3 0.9 3.8 0.4 1.2 0.8 3.4 0.4 213 27 220 255 15.1 0.1 15.7 14.6 06/13/2005 10:10:00 1.8 0.8 3.4 0.4 1.8 0.8 3.4 0.4 1.5 0.7 3.4 0.4 233 26 201 255 16.1 0.2 16.8 15.7 06/13/2005 10:20:00 1.8 0.7 4.2 0.4 1.8 0.7 3.8 0.4 1.5 0.8 4.2 0.4 238 23 253 255 17.1 0.1 17.4 16.6 06/13/2005 10:30:00 2.1 0.8 3.8 0.4 2 0.8 3.8 0.4 1.9 0.8 3.4 0.4 235 33 258 255 16.5 0.2 17.1 16.3 06/13/2005 10:40:00 1.5 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.4 0.8 3 0.4 270 38 282 255 17 0.3 18 16.6 06/13/2005 10:50:00 2.2 1 4.9 0.4 2.2 1 4.2 0.4 1.8 0.8 3.8 0.4 266 39 258 255 17.3 0.2 17.7 16.8 06/13/2005 11:00:00 2.3 1 4.2 0.4 2.3 1.1 4.6 0.4 2.1 1 4.6 0.4 246 22 273 255 17.1 0 17.1 16.8 06/13/2005 11:10:00 1.7 1 3.8 0.4 1.8 1 4.2 0.4 1.6 0.9 4.2 0.4 207 53 265 255 17.4 0.4 18.8 16.8 06/13/2005 11:20:00 1.9 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3.4 0.4 270 47 247 255 17.7 0.3 18.5 17.1 06/13/2005 11:30:00 3.1 1 4.6 0.4 3.1 0.9 4.6 0.4 2.5 1 4.6 0.4 287 29 310 255 18 0 18.5 17.7 06/13/2005 11:40:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 0.7 2.2 0.8 4.2 0.4 272 36 268 255 18.6 0.4 19.4 18 06/13/2005 11:50:00 2.6 1 4.6 0.4 2.5 1.1 4.6 0.4 2.1 0.9 4.6 0.4 290 33 272 255 19 0 19.7 18.8 06/13/2005 12:00:00 2 1 4.6 0.4 2 1 4.9 0.4 1.6 1 4.2 0.4 268 38 265 255 19 0.2 19.4 18.5 06/13/2005 12:10:00 1.9 1.4 6.1 0.4 1.9 1.3 6.5 0.4 1.7 1.2 5.7 0.4 312 64 315 255 19.3 0 19.7 19.1 06/13/2005 12:20:00 2.8 1.1 6.1 0.4 2.8 1.1 6.1 0.4 2.4 1.2 6.1 0.4 275 38 312 255 19.5 0.1 20 19.1 06/13/2005 12:30:00 2.7 1.1 5.3 0.4 2.7 1.1 5.7 0.4 2.2 1 5.7 0.4 287 33 290 255 19.5 0.1 20 19.1 06/13/2005 12:40:00 3.2 1 6.1 0.7 3.2 1 5.7 0.7 2.7 1.2 6.1 0.4 262 35 261 255 19.8 0.1 20.3 19.4 06/13/2005 12:50:00 2.6 0.9 5.7 0.4 2.6 1 6.5 0.4 2.3 1 5.3 0.4 238 23 253 255 19.6 0.2 20 19.4 06/13/2005 13:00:00 2.9 0.9 5.3 0.7 2.8 0.9 5.3 0.7 2.5 1 4.9 0.4 238 28 253 255 20 0 20.3 19.7 06/13/2005 13:10:00 2.7 0.8 4.6 0.7 2.7 0.8 4.6 0.7 2.2 1 4.9 0.4 235 43 252 255 20.5 0.2 20.8 20 06/13/2005 13:20:00 3.3 0.8 5.3 0.7 3.3 0.8 5.7 1.1 2.7 1 5.7 0.7 234 27 226 255 20.3 0 21.1 20.3 06/13/2005 13:30:00 2.2 1.1 4.9 0.4 2.2 1.1 4.6 0.4 2 0.9 4.2 0.4 265 58 300 255 20.2 0 20.8 20 06/13/2005 13:40:00 2.5 1.1 5.3 0.4 2.5 1.1 5.7 0.4 2 1 4.6 0.4 246 39 209 255 21 0.4 21.7 20 06/13/2005 13:50:00 1.5 1 3.8 0.4 1.5 1 3.8 0.4 1.3 0.8 3.4 0.4 219 45 264 255 20.5 0.1 21.7 20.3 06/13/2005 14:00:00 2.2 1.1 4.9 0.4 2.1 1.1 5.3 0.4 1.7 1.1 5.3 0.4 246 51 253 255 20.3 0.2 21.1 20 06/13/2005 14:10:00 2.5 1.2 5.3 0.4 2.5 1.2 5.3 0.4 2.1 1.1 4.6 0.4 257 39 240 255 21 0.1 21.4 20.5 06/13/2005 14:20:00 3.2 1.5 6.5 0.4 3.1 1.5 6.5 0.4 2.7 1.4 6.5 0.4 305 41 300 255 21.2 0.1 21.7 20.8 06/13/2005 14:30:00 3.8 0.8 6.8 1.5 3.7 0.8 6.8 1.5 3 1 5.3 0.7 304 23 340 255 21.3 0 21.7 21.1 06/13/2005 14:40:00 3.4 1 5.7 1.1 3.2 1 5.7 1.1 2.8 1 6.1 0.7 299 30 282 255 20.7 0.1 21.1 20.5 06/13/2005 14:50:00 2.9 1.1 5.7 0.4 2.9 1.1 5.7 0.4 2.6 1 4.9 0.4 271 53 288 255 20.9 0.1 21.1 20.8 06/13/2005 15:00:00 3.9 1.3 6.8 0.7 3.8 1.4 6.8 0.4 3.3 1.4 7.6 0.4 300 20 320 255 21.1 0.1 21.4 20.8 06/13/2005 15:10:00 1.5 0.9 3.8 0.4 1.6 0.9 4.6 0.4 1.4 0.8 3.8 0.4 267 30 272 255 21.3 0 21.7 21.1 06/13/2005 15:20:00 3 1 6.1 0.4 2.9 1 6.1 0.4 2.4 1 4.9 0.4 290 30 305 255 21.6 0 22 21.4 06/13/2005 15:30:00 2.7 1.1 4.9 0.4 2.7 1.1 5.3 0.4 2.2 1.2 4.6 0.4 268 43 260 255 21.3 0.1 21.7 21.1 06/13/2005 15:40:00 2.9 1.3 5.7 0.4 2.9 1.3 6.1 0.4 2.2 1.3 5.7 0.4 250 41 263 255 21.6 0 22 21.1 06/13/2005 15:50:00 3.1 1.1 5.7 0.7 3 1 5.3 0.7 2.6 1 5.3 0.4 298 36 319 255 21.3 0 21.4 21.1 06/13/2005 16:00:00 3.6 1.1 6.5 0.7 3.5 1.1 6.5 0.7 3.1 1 6.5 0.4 286 26 284 255 21 0.2 21.4 20.5 06/13/2005 16:10:00 3 1 5.3 0.4 2.9 1 4.9 0.7 2.6 1.1 4.9 0.4 282 33 272 255 20.5 0 20.8 20.3 06/13/2005 16:20:00 3.6 1.2 5.7 0.4 3.5 1.2 6.5 0.4 2.8 1.2 5.7 0.4 295 30 312 255 21.1 0.1 21.4 20.8 06/13/2005 16:30:00 2.7 1 4.6 0.4 2.6 1 4.6 0.4 2 1.1 4.2 0.4 272 29 291 255 20.8 0 21.1 20.5 06/13/2005 16:40:00 2.8 1 5.7 0.4 2.8 1 5.7 0.4 2.5 1 4.9 0.7 286 26 270 255 20.9 0 21.1 20.8 06/13/2005 16:50:00 2.8 0.9 4.9 0.7 2.8 0.9 4.9 0.7 2.2 1 4.9 0.4 294 22 313 255 20.7 0 21.1 20.5 06/13/2005 17:00:00 3.5 1 5.7 1.5 3.4 1 5.7 1.5 2.6 1 4.9 0.4 297 28 286 255 20.8 0.1 21.1 20.5 06/13/2005 17:10:00 2.3 1 4.2 0.4 2.2 1 4.6 0.4 2 0.8 4.6 0.4 283 41 260 255 20.6 0 20.8 20.5 06/13/2005 17:20:00 2.4 1 4.9 0.4 2.5 1 4.9 0.4 2 1 4.2 0.4 275 36 247 255 20.5 0 20.8 20.3 06/13/2005 17:30:00 3.1 1 6.1 0.4 3 1 5.7 0.7 2.6 0.9 5.3 1.1 274 24 269 255 20.1 0 20.8 20 06/13/2005 17:40:00 2.7 0.8 4.6 0.7 2.7 0.8 4.6 1.1 2.2 0.9 4.2 0.4 289 26 287 255 20 0 20.3 20 06/13/2005 17:50:00 2.5 1.1 5.7 0.4 2.6 1 5.3 0.4 2 1 4.9 0.4 273 33 297 255 20 0 20.3 20 06/13/2005 18:00:00 3.3 1.1 6.1 1.1 3.3 1.1 5.7 1.1 2.8 1.1 6.1 0.4 282 28 288 255 19.8 0 20.3 19.7 06/13/2005 18:10:00 3 0.9 4.9 1.1 3 0.9 4.9 0.7 2.5 1.1 4.9 0.4 291 20 293 255 19.7 0 20 19.7 06/13/2005 18:20:00 2.4 0.7 4.2 0.4 2.3 0.7 4.2 0.7 1.9 0.7 3.4 0.4 303 23 314 255 19.7 0 20 19.4 06/13/2005 18:30:00 2.9 0.8 4.6 1.1 2.9 0.7 4.6 0.7 2.4 0.9 4.9 0.7 291 15 315 255 19.5 0 19.7 19.4 06/13/2005 18:40:00 3.1 0.7 4.6 1.5 3.1 0.7 4.6 1.5 2.7 0.8 4.6 0.4 294 15 286 255 19.4 0 19.4 19.1 06/13/2005 18:50:00 2.8 0.9 4.9 0.7 2.7 0.9 4.6 1.1 2.4 1 4.9 0.4 289 20 308 255 19.2 0 19.4 19.1 06/13/2005 19:00:00 2.1 0.8 3.8 0.4 2.1 0.8 3.8 0.4 1.6 0.8 4.2 0.4 278 30 242 255 19.1 0 19.4 18.8 06/13/2005 19:10:00 2.6 0.6 4.6 1.1 2.6 0.6 4.2 0.7 2.2 0.8 3.8 0.4 290 19 271 255 19 0 19.4 18.5 06/13/2005 19:20:00 2.8 0.7 4.9 0.7 2.8 0.7 4.9 0.7 2.4 0.7 4.2 0.7 295 21 297 255 18.7 0 19.4 18.5 06/13/2005 19:30:00 2.4 0.8 4.6 0.7 2.5 0.7 4.2 1.1 2.2 0.7 4.2 0.7 286 15 287 255 18.7 0 19.1 18.5 06/13/2005 19:40:00 3 0.8 4.6 1.1 3 0.8 4.9 1.1 2.4 0.9 4.6 0.7 285 21 289 255 18.6 0 19.1 18.5 06/13/2005 19:50:00 2.3 0.8 4.2 0.7 2.2 0.8 4.2 0.7 2.1 0.8 4.2 0.7 286 18 300 255 18.4 0 18.8 18.2 06/13/2005 20:00:00 2.1 0.9 4.9 0.4 2.2 1 4.9 0.4 1.8 1.1 4.9 0.4 280 26 286 255 18 0.1 18.2 17.7 06/13/2005 20:10:00 3.1 0.9 5.3 1.1 3 1 4.9 0.7 2.6 0.8 4.9 0.7 289 15 305 255 17.8 0 18 17.7 06/13/2005 20:20:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.7 1.8 0.6 3.8 0.4 270 22 310 255 17.5 0 17.7 17.4 06/13/2005 20:30:00 2 1 4.9 0.4 2.1 1 4.6 0.4 1.6 0.8 4.2 0.4 279 19 258 255 17.4 0 17.7 17.1 06/13/2005 20:40:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1 0.4 2.3 0.4 287 12 294 255 17.1 0 17.4 16.8 06/13/2005 20:50:00 2 0.5 3 0.7 2 0.5 3.4 0.7 1.3 0.5 2.6 0.4 273 17 286 255 16.4 0.2 16.8 16 06/13/2005 21:00:00 2.9 0.9 4.6 0.7 2.8 1 4.6 0.4 2 0.9 4.2 0.4 269 16 263 255 15.9 0 16.3 16 06/13/2005 21:10:00 2.1 0.8 4.2 0.4 2.2 0.7 4.2 0.4 1.4 0.7 3.4 0.4 274 17 257 255 15.9 0 16.3 15.7 06/13/2005 21:20:00 1.7 0.8 3.4 0.4 1.7 0.7 3.4 0.4 1.2 0.6 2.6 0.4 268 17 263 255 15.5 0 16 15.5 06/13/2005 21:30:00 1.8 0.8 4.2 0.4 1.9 0.7 4.2 0.4 1.3 0.6 3 0.4 265 22 243 255 15.5 0 16 15.5 06/13/2005 21:40:00 1.6 0.8 4.2 0.4 1.7 0.8 4.2 0.4 0.9 0.6 3 0.4 262 17 263 255 15.5 0 15.7 15.5 06/13/2005 21:50:00 2 0.8 3.8 0.4 2 0.7 3.8 0.4 1.4 0.7 3 0.4 249 15 255 255 15.4 0 15.7 15.2 06/13/2005 22:00:00 2.2 0.8 4.2 0.4 2.3 0.7 3.8 0.4 1.4 0.8 3.4 0.4 252 15 252 255 15 0 15.7 14.9 06/13/2005 22:10:00 2.3 0.7 4.6 0.4 2.3 0.8 4.6 0.4 1.6 0.7 3.4 0.4 258 22 261 255 15 0 15.7 14.9 06/13/2005 22:20:00 1.9 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.2 0.7 3.4 0.4 254 16 246 255 14.9 0 15.5 14.6 06/13/2005 22:30:00 1.8 0.6 3.4 0.4 2 0.6 3.4 0.7 1.2 0.5 2.6 0.4 239 15 242 255 14.7 0.1 15.2 14.6 06/13/2005 22:40:00 1.8 0.4 3 0.7 1.9 0.4 2.6 0.7 1.1 0.5 2.3 0.4 214 19 238 255 14.4 0.3 15.2 13.8 06/13/2005 22:50:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 1.3 0.4 2.6 0.4 198 9 193 255 13.9 0 14.4 13.5 06/13/2005 23:00:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.6 0.4 1.9 0.4 197 3 196 255 13.5 0 14.1 13.3 06/13/2005 23:10:00 0.6 0.4 1.9 0.4 0.5 0.4 2.3 0.4 0.4 0.1 1.1 0.4 211 10 217 255 13.3 0 13.8 13 06/13/2005 23:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 276 79 218 255 13.1 0 13.5 13 06/13/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 255 255 13 0.1 13.3 12.7 06/13/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 255 255 13.1 0 13.3 13 06/13/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 94 255 255 13.1 0 13.3 13 06/14/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 0 255 255 13 0.1 13.3 12.7 06/14/2005 00:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 135 47 75 255 12.9 0 13.3 12.7 06/14/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 75 0 255 255 12.8 0 13.3 12.7 06/14/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.7 0 13.3 12.7 06/14/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.7 0 13.3 12.7 06/14/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.7 0 13.3 12.7 06/14/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.7 0 13.3 12.5 06/14/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.5 0.1 13 12.5 06/14/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.4 0 12.7 12.5 06/14/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.5 0 12.5 12.5 06/14/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.5 0 12.7 12.5 06/14/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 12.4 0 12.5 12.2 06/14/2005 02:00:00 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 41 51 334 255 12.4 0 12.5 12.5 06/14/2005 02:10:00 1 0.4 1.9 0.4 0.7 0.3 1.1 0.4 0.6 0.3 1.5 0.4 345 15 333 255 12.3 0 12.5 12.2 06/14/2005 02:20:00 0.6 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 350 12 351 255 12.2 0 12.5 11.9 06/14/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 255 255 11.9 0 12.2 11.7 06/14/2005 02:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 341 255 11.7 0 11.9 11.4 06/14/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 255 255 11.4 0 11.7 11.1 06/14/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 255 255 11.1 0 11.7 10.9 06/14/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 255 255 10.8 0.1 11.4 10.6 06/14/2005 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 341 0 341 255 10.5 0 10.6 10.6 06/14/2005 03:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 341 0 341 255 10.3 0 10.6 10.3 06/14/2005 03:40:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 341 0 341 255 10.1 0 10.3 9.8 06/14/2005 03:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 341 0 341 255 9.9 0 10.1 9.8 06/14/2005 04:00:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 341 0 341 255 9.7 0 9.8 9.6 06/14/2005 04:10:00 0.9 0.3 1.9 0.4 0.7 0.3 1.9 0.4 0.4 0 0.4 0.4 21 23 51 255 9.5 0 9.6 9.6 06/14/2005 04:20:00 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 54 7 62 255 9.5 0 9.6 9.3 06/14/2005 04:30:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 13 32 346 255 9.3 0 9.8 9.3 06/14/2005 04:40:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 1.1 0.9 0.4 1.9 0.4 4 15 10 255 9.8 0.2 10.3 9.3 06/14/2005 04:50:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 7 15 23 255 10.6 0.2 11.1 10.3 06/14/2005 05:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 20 1 22 255 11.6 0.2 11.9 11.1 06/14/2005 05:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 18 4 13 255 12.4 0.2 12.7 11.9 06/14/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 0 255 255 12.5 0 12.7 12.5 06/14/2005 05:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 55 22 68 255 12.5 0 12.5 12.2 06/14/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 0 255 255 12.7 0 12.7 12.5 06/14/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 0 255 255 13.7 0.5 14.6 12.7 06/14/2005 06:00:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 260 79 220 255 15 0.1 15.7 14.6 06/14/2005 06:10:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 228 17 220 255 15.6 0.3 16.3 14.9 06/14/2005 06:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 239 15 250 255 15.6 0.2 16.3 15.2 06/14/2005 06:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 251 0 251 255 15.2 0 15.5 15.2 06/14/2005 06:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 303 39 295 255 15.5 0 16 15.2 06/14/2005 06:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 339 35 8 255 15.9 0 16.6 15.7 06/14/2005 07:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 334 33 303 255 15.8 0 16.3 15.7 06/14/2005 07:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 329 41 266 255 15.9 0 16.3 15.7 06/14/2005 07:20:00 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 302 16 291 255 15.9 0.1 16.3 15.7 06/14/2005 07:30:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 297 14 300 255 16.7 0.2 17.1 16.3 06/14/2005 07:40:00 1.1 0.5 2.6 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 326 39 296 255 16.9 0.1 17.4 16.8 06/14/2005 07:50:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 0.8 0.3 1.9 0.4 338 26 12 255 16.8 0 17.4 16.8 06/14/2005 08:00:00 1.6 0.5 3 0.4 1.4 0.6 3 0.4 1.2 0.4 2.3 0.4 319 33 277 255 16.7 0 17.1 16.6 06/14/2005 08:10:00 1.8 0.4 2.6 0.4 1.5 0.5 2.3 0.4 1.3 0.5 2.6 0.4 323 16 328 255 16.2 0.1 16.8 16.3 06/14/2005 08:20:00 1.8 0.5 3 0.4 1.6 0.5 2.6 0.4 1.5 0.6 3 0.4 306 17 301 255 16.6 0 17.1 16.3 06/14/2005 08:30:00 1.8 0.5 3 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 319 14 336 255 16.9 0 17.4 16.8 06/14/2005 08:40:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.5 2.3 0.4 330 32 311 255 16.8 0 17.1 16.6 06/14/2005 08:50:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.4 2.3 0.4 302 15 284 255 16.6 0 16.8 16.6 06/14/2005 09:00:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.5 2.6 0.4 307 23 253 255 16.8 0.1 17.1 16.6 06/14/2005 09:10:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 328 27 332 255 17 0 17.1 16.8 06/14/2005 09:20:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.4 0.8 3.4 0.4 323 27 308 255 17.5 0.4 18.2 16.8 06/14/2005 09:30:00 1.8 0.7 3 0.4 1.6 0.7 2.6 0.4 1.4 0.7 3 0.4 325 27 341 255 18 0.1 18.5 17.7 06/14/2005 09:40:00 2.2 0.5 3.4 0.7 2 0.5 3 0.4 1.9 0.5 3.4 0.4 315 22 307 255 18.7 0.3 19.4 18.2 06/14/2005 09:50:00 2.3 0.7 3.8 0.7 2.2 0.7 3.8 0.4 2 0.7 3.4 0.4 318 21 310 255 19 0 19.7 18.8 06/14/2005 10:00:00 1.4 0.7 3 0.4 1.2 0.7 2.6 0.4 1 0.5 2.6 0.4 275 76 358 255 19.7 0.4 20.5 18.8 06/14/2005 10:10:00 1.9 0.9 4.2 0.4 1.9 0.9 3.8 0.4 1.5 0.8 3.4 0.4 243 23 255 255 20 0.2 20.5 19.7 06/14/2005 10:20:00 1.3 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.1 0.7 3.4 0.4 283 66 251 255 19.7 0.1 20.3 19.4 06/14/2005 10:30:00 1.8 0.9 3.4 0.4 1.7 0.9 3.8 0.4 1.5 0.9 3.4 0.4 272 76 289 255 20 0 20.5 19.7 06/14/2005 10:40:00 1.2 0.7 3.4 0.4 1.1 0.7 3.4 0.4 1.1 0.6 3 0.4 273 79 215 255 20.2 0.3 20.5 19.7 06/14/2005 10:50:00 1.8 0.9 4.2 0.4 1.6 0.9 4.2 0.4 1.4 0.9 4.2 0.4 318 45 312 255 20.6 0 20.8 20.3 06/14/2005 11:00:00 2.2 1 4.6 0.4 2.1 1 4.9 0.4 1.9 1 4.6 0.4 261 41 321 255 20.8 0 21.1 20.5 06/14/2005 11:10:00 2.2 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.9 0.9 4.6 0.4 294 36 257 255 21.2 0.1 21.4 20.8 06/14/2005 11:20:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.5 0.6 3.4 0.4 295 29 290 255 21.1 0 21.1 20.8 06/14/2005 11:30:00 2.6 0.7 3.8 0.7 2.6 0.6 3.8 0.7 2.3 0.7 4.2 0.4 291 24 286 255 21.3 0 21.7 21.1 06/14/2005 11:40:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.8 3.4 0.4 354 36 266 255 21.7 0.1 22.3 21.4 06/14/2005 11:50:00 1 0.6 2.6 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 232 79 312 255 22.1 0.2 22.9 21.7 06/14/2005 12:00:00 2.1 1 4.2 0.4 2 1 3.8 0.4 1.9 1 3.8 0.4 237 45 264 255 22 0.1 22.3 21.7 06/14/2005 12:10:00 1.8 0.7 4.9 0.4 1.7 0.7 4.2 0.4 1.6 0.7 3.4 0.4 270 90 284 255 22.4 0 22.9 22 06/14/2005 12:20:00 2.6 1 5.3 0.7 2.5 1 4.9 0.4 2.1 0.9 4.9 0.4 273 28 314 255 22.3 0.4 22.9 21.4 06/14/2005 12:30:00 1.7 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1.6 0.9 3.4 0.4 275 90 286 255 21.3 0 21.7 21.1 06/14/2005 12:40:00 3.2 0.8 5.3 1.1 3 0.9 5.3 0.7 2.5 0.9 4.6 0.4 314 23 306 255 22.1 0.1 22.3 21.7 06/14/2005 12:50:00 2.5 1 4.6 0.4 2.4 1 4.6 0.4 2 1 4.6 0.4 319 29 304 255 22.5 0.2 22.9 22.3 06/14/2005 13:00:00 2.3 1 5.3 0.4 2.1 1.1 5.7 0.4 1.8 1 4.6 0.4 306 41 260 255 23.3 0.1 23.5 22.9 06/14/2005 13:10:00 3.1 0.9 6.5 1.1 3 1 5.7 0.7 2.7 1 4.6 0.4 305 22 296 255 23.1 0 23.5 22.9 06/14/2005 13:20:00 3.3 0.8 5.3 1.5 3.2 0.8 5.3 1.1 2.9 0.9 4.9 1.1 311 23 280 255 22.3 0.6 23.5 21.4 06/14/2005 13:30:00 2.5 0.8 4.6 0.4 2.3 0.8 3.8 0.4 1.9 0.7 3.8 0.4 316 22 339 255 21.5 0 21.7 21.1 06/14/2005 13:40:00 2.8 0.7 4.6 1.1 2.7 0.7 4.2 1.1 2.4 0.9 4.9 0.4 310 13 312 255 22.6 0.4 23.2 21.4 06/14/2005 13:50:00 2.8 0.9 5.3 0.7 2.6 0.9 4.9 0.4 2.3 1 5.3 0.7 314 20 312 255 23.5 0.2 23.8 23.2 06/14/2005 14:00:00 2.2 0.7 4.2 0.4 2.1 0.8 3.8 0.4 1.8 0.9 4.6 0.4 318 39 287 255 24 0.1 24.4 23.8 06/14/2005 14:10:00 2.4 1.1 5.3 0.4 2.3 1.1 5.7 0.4 2 1 3.8 0.4 306 28 337 255 24.4 0 24.7 24.1 06/14/2005 14:20:00 2.7 1.3 6.1 0.4 2.6 1.4 5.7 0.4 2.2 1.2 5.3 0.4 304 58 305 255 24.8 0.2 25.3 24.4 06/14/2005 14:30:00 2.3 1.1 4.9 0.4 2.2 1.1 4.9 0.4 2 1.1 4.6 0.4 294 35 298 255 24.7 0.2 25.3 24.4 06/14/2005 14:40:00 1.6 1 4.6 0.4 1.6 1 4.6 0.4 1.6 1 4.2 0.4 286 45 282 255 24.6 0 25.3 24.4 06/14/2005 14:50:00 1.7 0.9 3.8 0.4 1.6 0.9 4.2 0.4 1.3 0.7 3.4 0.4 280 64 299 255 24.6 0.2 25 24.1 06/14/2005 15:00:00 3 0.8 4.9 0.7 2.9 0.8 4.9 0.7 2.6 0.9 4.9 0.4 295 30 308 255 25.3 0 25.6 25 06/14/2005 15:10:00 2 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 290 35 340 255 25 0 25.3 25 06/14/2005 15:20:00 2.8 0.9 4.9 0.7 2.8 0.9 4.9 0.4 2.6 1 4.9 0.7 264 33 263 255 25 0 25.6 25 06/14/2005 15:30:00 1.7 0.9 3.8 0.4 1.6 0.9 3.4 0.4 1.3 1 3.8 0.4 282 76 304 255 25 0.2 25.6 24.7 06/14/2005 15:40:00 1.8 0.8 3.8 0.4 1.6 0.8 4.2 0.4 1.6 0.7 3.4 0.4 309 35 276 255 25.3 0.2 25.6 25 06/14/2005 15:50:00 2.4 0.9 4.6 0.4 2.3 0.9 4.6 0.4 2.1 0.9 4.2 0.4 262 29 280 255 24.7 0.2 25.3 24.1 06/14/2005 16:00:00 2 1.2 5.3 0.4 1.9 1.2 5.3 0.4 1.8 1 5.3 0.4 238 82 259 255 23.9 0 24.4 23.5 06/14/2005 16:10:00 2.1 1 4.6 0.4 2 1 4.2 0.4 1.6 0.9 3.8 0.4 287 27 284 255 23.2 0.2 23.8 22.9 06/14/2005 16:20:00 2.9 0.9 4.9 0.4 2.8 0.9 4.6 0.7 2.3 1 4.6 0.4 286 23 300 255 23 0.3 23.8 22.6 06/14/2005 16:30:00 2.7 1.1 4.9 0.4 2.6 1.1 4.9 0.4 2.2 1.2 4.9 0.4 270 36 306 255 24 0.1 24.4 23.8 06/14/2005 16:40:00 3 1 5.3 0.7 2.9 1.1 5.3 0.4 2.6 1.3 5.7 0.4 281 22 235 255 24.4 0 24.7 24.1 06/14/2005 16:50:00 2.4 1 4.9 0.4 2.3 1 4.6 0.4 2.1 0.9 5.3 0.4 281 36 265 255 24.4 0 24.7 24.1 06/14/2005 17:00:00 3 1 5.3 0.7 3 0.9 5.3 1.1 2.5 1 5.3 0.4 279 32 335 255 24.3 0 24.4 24.1 06/14/2005 17:10:00 3.2 1.2 6.1 0.4 3.1 1.2 6.1 0.7 2.6 1.5 6.1 0.4 290 30 291 255 23.9 0 24.1 23.8 06/14/2005 17:20:00 3.6 1.1 6.1 0.7 3.5 1.2 6.1 0.7 3.1 1 5.7 0.7 299 22 293 255 23.8 0 23.8 23.8 06/14/2005 17:30:00 4 1.1 6.5 1.1 3.9 1.2 6.5 0.7 3 1.2 6.1 0.4 298 26 288 255 23.7 0 23.8 23.5 06/14/2005 17:40:00 3.3 1.1 5.3 0.4 3.2 1 5.3 0.7 2.7 1 5.3 0.7 289 32 317 255 23.6 0 23.8 23.5 06/14/2005 17:50:00 2.9 1.2 5.7 0.4 2.8 1.2 5.3 0.4 2.6 1.1 4.9 0.4 289 30 284 255 23.7 0 23.8 23.5 06/14/2005 18:00:00 3.8 0.7 5.7 2.3 3.7 0.7 5.7 1.9 3.3 0.8 5.7 1.9 289 17 282 255 23.8 0 23.8 23.8 06/14/2005 18:10:00 3.1 1.1 5.7 0.4 3.1 1.1 5.7 0.4 2.8 1.1 5.7 0.4 286 26 298 255 23.8 0 24.1 23.8 06/14/2005 18:20:00 3.1 1.1 5.3 0.4 3 1 5.7 0.7 2.5 1 4.9 0.4 271 23 268 255 23.8 0 23.8 23.8 06/14/2005 18:30:00 3.2 1.1 5.3 0.4 3.2 1 5.3 0.4 2.7 1.1 5.3 0.4 292 22 269 255 23.5 0 23.8 23.5 06/14/2005 18:40:00 3.1 1 4.9 0.4 3 1 4.9 0.4 2.6 1 4.9 0.4 297 17 307 255 23 0.2 23.5 22.6 06/14/2005 18:50:00 2.5 0.6 3.8 0.7 2.4 0.7 3.8 0.4 2 0.7 3.8 0.4 296 17 322 255 22.3 0.1 22.6 22 06/14/2005 19:00:00 1.9 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.4 0.8 5.3 0.4 280 12 282 255 21.9 0 22.6 21.7 06/14/2005 19:10:00 2.9 1.1 5.3 0.4 2.8 1.1 4.9 0.4 2.1 1 4.2 0.4 298 15 285 255 21.9 0 22.3 21.7 06/14/2005 19:20:00 3.1 0.9 4.9 0.4 3.1 1 4.9 0.4 2.6 0.9 4.2 0.4 287 17 322 255 21.7 0 22 21.7 06/14/2005 19:30:00 2 0.7 3.4 0.4 2 0.7 3.8 0.4 1.8 0.8 3.4 0.4 275 23 288 255 21.7 0 22 21.4 06/14/2005 19:40:00 2 0.8 4.2 0.4 2 0.8 4.2 0.4 1.6 0.6 3.8 0.4 265 22 268 255 21.5 0 22 21.1 06/14/2005 19:50:00 1.9 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.3 0.8 3.4 0.4 277 23 263 255 21.4 0.1 22 21.1 06/14/2005 20:00:00 2.2 0.6 4.2 0.7 2.2 0.7 4.2 0.4 1.9 0.6 4.2 0.4 282 15 268 255 21 0.1 21.4 20.8 06/14/2005 20:10:00 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 283 14 283 255 20.8 0.1 21.1 20.5 06/14/2005 20:20:00 1.9 0.6 3 0.4 1.8 0.7 3.4 0.4 1.4 0.6 3 0.4 285 15 274 255 20.1 0 20.8 19.7 06/14/2005 20:30:00 2.3 0.7 4.2 0.4 2.3 0.7 3.8 0.4 1.7 0.7 3.4 0.4 284 13 293 255 19.5 0 20.3 19.4 06/14/2005 20:40:00 1.4 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1 0.4 1.9 0.4 278 11 274 255 19.1 0.1 20 18.8 06/14/2005 20:50:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1 0.4 1.9 0.4 296 9 300 255 18.4 0 18.8 18 06/14/2005 21:00:00 1.8 0.5 3 0.4 1.8 0.5 3 0.4 1.2 0.4 2.3 0.4 285 12 285 255 17.8 0.1 18 17.4 06/14/2005 21:10:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.8 0.4 1.9 0.4 285 8 286 255 17.2 0 17.4 16.8 06/14/2005 21:20:00 1.4 0.4 2.6 0.4 1.4 0.5 2.3 0.4 0.7 0.3 1.9 0.4 283 5 286 255 16.8 0 17.1 16.6 06/14/2005 21:30:00 1.9 0.5 3.4 0.7 1.8 0.6 3.4 0.4 0.9 0.5 2.6 0.4 272 15 272 255 16.2 0.1 16.8 16 06/14/2005 21:40:00 2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.2 0.6 2.6 0.4 276 13 289 255 15.8 0 16.3 15.7 06/14/2005 21:50:00 2 0.7 3.8 0.4 2 0.7 4.2 0.4 1.2 0.7 3 0.4 272 15 281 255 15.5 0 15.7 15.5 06/14/2005 22:00:00 2.2 0.7 3.8 0.4 2.3 0.7 3.8 0.4 1.3 0.6 3.4 0.4 271 17 273 255 15.4 0 15.7 15.2 06/14/2005 22:10:00 2.2 0.9 4.6 0.4 2.2 1 4.6 0.4 1.4 0.8 3.8 0.4 269 19 262 255 15.2 0 15.7 15.2 06/14/2005 22:20:00 2.1 0.7 3.8 0.7 2.1 0.7 3.8 0.4 1.2 0.7 3 0.4 260 18 255 255 15.3 0 15.7 15.2 06/14/2005 22:30:00 2.2 0.9 4.9 0.4 2.2 0.9 4.9 0.4 1.4 0.8 3.4 0.4 272 18 260 255 15.2 0.1 15.7 15.2 06/14/2005 22:40:00 2.1 0.8 4.6 0.4 2 0.9 4.9 0.4 1.3 0.8 3.4 0.4 277 18 268 255 15.2 0.1 15.7 15.2 06/14/2005 22:50:00 2.4 0.9 4.9 0.4 2.4 0.9 4.9 0.7 1.4 0.9 4.2 0.4 274 18 252 255 15.2 0.1 15.7 15.2 06/14/2005 23:00:00 2.5 0.8 4.9 0.7 2.4 0.8 4.9 0.4 1.8 0.7 4.6 0.4 245 20 255 255 15.3 0.1 15.7 15.2 06/14/2005 23:10:00 2.4 0.9 4.9 0.7 2.4 0.8 4.9 0.7 1.7 0.7 3.8 0.4 235 20 219 255 15 0 15.7 14.6 06/14/2005 23:20:00 2.5 0.7 4.6 0.4 2.5 0.7 4.2 0.7 1.8 0.7 3.8 0.4 236 18 225 255 14.7 0.1 15.2 14.6 06/14/2005 23:30:00 2.2 0.8 4.6 0.4 2.2 0.8 4.6 0.4 1.4 0.7 3.4 0.4 239 18 275 255 14.2 0.1 14.9 14.1 06/14/2005 23:40:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 214 15 204 255 13.9 0 14.6 13.8 06/14/2005 23:50:00 1.7 0.5 3 0.7 1.7 0.5 3 0.7 0.8 0.4 2.3 0.4 217 11 205 255 13.4 0.2 14.1 13 06/15/2005 00:00:00 1.1 0.6 3 0.4 1 0.6 3.4 0.4 0.5 0.3 1.9 0.4 236 11 219 255 12.7 0 13 12.5 06/15/2005 00:10:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 233 10 240 255 12.3 0 12.7 12.2 06/15/2005 00:20:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.7 0.4 1.9 0.4 203 16 200 255 12 0.1 12.5 11.9 06/15/2005 00:30:00 1.4 0.4 2.3 0.4 1.5 0.5 2.3 0.4 1 0.5 2.3 0.4 184 8 202 255 11.7 0 12.5 11.7 06/15/2005 00:40:00 1.8 0.5 3.4 0.4 1.8 0.6 3.4 0.4 0.9 0.5 2.6 0.4 198 13 203 255 11.6 0 11.9 11.4 06/15/2005 00:50:00 1.4 0.5 3 0.4 1.3 0.6 3 0.4 0.5 0.3 1.5 0.4 223 15 213 255 11.3 0 11.7 11.1 06/15/2005 01:00:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.5 1.2 0.5 2.6 0.4 220 13 205 255 11 0 11.4 10.9 06/15/2005 01:10:00 2.9 0.6 4.6 1.1 3 0.5 4.2 1.5 2.1 0.5 3.4 0.7 198 13 211 255 10.8 0 11.4 10.6 06/15/2005 01:20:00 1.9 0.4 3 0.7 2.4 0.3 3 1.5 1.5 0.4 2.6 0.4 177 9 189 255 10.7 0 10.9 10.6 06/15/2005 01:30:00 1.9 0.4 3 1.1 2.5 0.4 3.4 1.5 1.6 0.4 2.6 0.4 181 9 204 255 10.8 0 11.1 10.6 06/15/2005 01:40:00 2 0.4 3.4 1.1 2.4 0.4 3.4 1.5 1.5 0.4 2.6 0.4 183 7 189 255 10.7 0 10.9 10.6 06/15/2005 01:50:00 1.9 0.5 3 0.7 2.1 0.3 3 1.1 1.4 0.3 2.3 0.7 184 7 192 255 10.6 0 10.9 10.6 06/15/2005 02:00:00 2 0.3 2.6 1.1 2.2 0.2 2.6 1.5 1.5 0.3 2.3 0.7 163 5 167 255 10.4 0.1 10.6 10.3 06/15/2005 02:10:00 1.7 0.3 2.3 1.1 2.5 0.3 3 1.5 1.6 0.4 2.6 0.7 171 6 166 255 10.1 0 10.3 10.1 06/15/2005 02:20:00 1.7 0.3 2.6 1.1 2.5 0.3 3.4 1.5 1.7 0.3 2.6 1.1 174 7 184 255 10.2 0 10.3 10.1 06/15/2005 02:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 0.5 0.3 1.9 0.4 175 13 168 255 9.9 0 10.3 9.8 06/15/2005 02:40:00 0.6 0.3 1.9 0.4 0.7 0.4 2.3 0.4 0.4 0 0.4 0.4 170 3 170 255 9.7 0 10.3 9.6 06/15/2005 02:50:00 1 0.5 1.9 0.4 1.2 0.4 1.9 0.4 0.5 0.3 1.5 0.4 169 4 171 255 9.5 0 10.1 9.3 06/15/2005 03:00:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1 0.4 1.9 0.4 149 8 147 255 9.4 0 9.8 9 06/15/2005 03:10:00 1.7 0.3 2.3 1.1 1.7 0.3 2.3 0.7 1.1 0.3 1.9 0.4 143 3 152 255 9 0 9.6 9 06/15/2005 03:20:00 1.6 0.3 1.9 0.7 1.5 0.3 2.3 0.7 0.8 0.3 1.5 0.4 142 0 142 255 8.9 0 9 8.8 06/15/2005 03:30:00 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0 0.7 0.4 142 0 142 255 8.9 0 9 8.8 06/15/2005 03:40:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 137 10 126 255 8.9 0 9 8.8 06/15/2005 03:50:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1 0.4 1.9 0.4 134 8 121 255 8.9 0 9 8.8 06/15/2005 04:00:00 1.9 0.4 2.6 1.1 1.9 0.4 3 1.1 1.1 0.4 2.3 0.4 134 7 130 255 8.6 0 8.8 8.5 06/15/2005 04:10:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.1 1.7 0.3 2.6 0.7 133 7 125 255 8.6 0 8.8 8.5 06/15/2005 04:20:00 2 0.4 3 1.1 2 0.4 3 0.7 1.4 0.4 2.6 0.4 132 6 121 255 8.6 0 8.8 8.5 06/15/2005 04:30:00 2.1 0.4 3 1.5 2.2 0.4 3 1.1 1.4 0.4 2.6 0.7 128 7 126 255 8.7 0 8.8 8.8 06/15/2005 04:40:00 1.9 0.4 3 0.7 1.9 0.4 3 0.7 1.3 0.4 2.3 0.4 131 9 118 255 8.9 0 9 8.8 06/15/2005 04:50:00 2.4 0.5 3 1.1 2.4 0.5 3 1.5 1.6 0.3 2.6 0.7 122 8 133 255 9 0 9 9 06/15/2005 05:00:00 2.5 0.5 3.4 0.7 2.5 0.5 3.4 1.1 1.9 0.4 3 1.1 123 8 115 255 8.9 0 9 9 06/15/2005 05:10:00 1.5 0.5 3 0.7 1.5 0.5 3 0.7 1 0.4 2.3 0.4 133 11 122 255 9.4 0.2 9.8 9 06/15/2005 05:20:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.4 1.9 0.4 125 9 123 255 10 0.2 10.6 9.6 06/15/2005 05:30:00 1.5 0.4 2.6 0.4 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 122 11 115 255 10.9 0.2 11.4 10.6 06/15/2005 05:40:00 0.8 0.3 1.9 0.4 0.7 0.3 1.9 0.4 0.5 0.2 1.1 0.4 123 13 119 255 12 0.2 12.5 11.4 06/15/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 123 0 124 255 13.3 0.5 13.8 12.5 06/15/2005 06:00:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 29 27 18 255 14.4 0.2 15.2 13.8 06/15/2005 06:10:00 1.3 0.6 2.6 0.4 1.2 0.6 2.3 0.4 1 0.5 2.3 0.4 12 16 7 255 15.5 0.2 16.3 15.2 06/15/2005 06:20:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.5 0.4 2.3 0.4 32 12 48 255 15.7 0 16.3 15.5 06/15/2005 06:30:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.4 0.5 2.6 0.4 42 14 46 255 15.7 0 16.3 15.7 06/15/2005 06:40:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 42 14 26 255 15.5 0.2 16.3 15.2 06/15/2005 06:50:00 1.6 0.4 3 0.7 1.6 0.4 2.6 0.4 1.4 0.5 2.6 0.4 29 12 30 255 15.9 0.3 16.8 15.2 06/15/2005 07:00:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 0.4 1.6 0.4 2.6 0.7 29 14 28 255 16.7 0 16.8 16.6 06/15/2005 07:10:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 24 10 34 255 16.7 0 17.4 16.6 06/15/2005 07:20:00 1.6 0.3 2.6 0.4 1.6 0.3 2.6 0.4 1.4 0.4 2.3 0.4 15 14 17 255 17.2 0 17.7 16.8 06/15/2005 07:30:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.4 38 15 3 255 17.1 0 17.7 16.8 06/15/2005 07:40:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 50 8 49 255 17.2 0.1 17.7 16.8 06/15/2005 07:50:00 1.4 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 40 15 53 255 17.6 0.1 18.2 17.1 06/15/2005 08:00:00 1.7 0.4 3 0.7 1.6 0.4 3 0.7 1.5 0.5 2.6 0.7 20 17 14 255 17.9 0.1 18.5 17.7 06/15/2005 08:10:00 1.5 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 15 17 14 255 18.4 0 18.8 18.2 06/15/2005 08:20:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 6 20 348 255 18.8 0.2 19.4 18.2 06/15/2005 08:30:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 331 29 15 255 19 0 19.4 18.8 06/15/2005 08:40:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 355 21 15 255 19.1 0 19.4 18.8 06/15/2005 08:50:00 1.6 0.7 3 0.4 1.5 0.7 3 0.4 1.4 0.6 3 0.4 8 22 6 255 19.6 0.1 20 19.4 06/15/2005 09:00:00 1.3 0.7 3 0.4 1.1 0.7 3 0.4 1 0.6 2.6 0.4 11 19 10 255 19.6 0.1 20 19.4 06/15/2005 09:10:00 1.4 0.6 3.4 0.4 1.4 0.6 3.4 0.4 1.2 0.6 3 0.4 45 20 34 255 19.8 0 20.3 19.4 06/15/2005 09:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 2.6 0.4 23 36 345 255 20.2 0 20.5 19.7 06/15/2005 09:30:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 0 36 348 255 20.3 0.1 20.5 20 06/15/2005 09:40:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 40 23 121 255 20.1 0 20.3 20 06/15/2005 09:50:00 2.3 0.6 3.8 0.4 2.2 0.6 3.8 0.4 1.9 0.7 3.4 0.4 327 29 308 255 20.8 0.2 21.1 20.3 06/15/2005 10:00:00 1.7 0.6 3 0.4 1.7 0.7 3 0.4 1.3 0.7 3.4 0.4 271 26 261 255 21.3 0 21.7 21.1 06/15/2005 10:10:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.8 0.7 3.8 0.4 291 47 281 255 21 0 21.4 20.8 06/15/2005 10:20:00 2 1 4.2 0.4 2 1 3.8 0.4 1.9 0.9 3.8 0.4 259 45 270 255 21 0 21.4 20.8 06/15/2005 10:30:00 1.7 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3 0.4 244 58 274 255 21.6 0.3 22.3 21.1 06/15/2005 10:40:00 1.9 0.8 4.2 0.4 1.9 0.8 4.6 0.4 1.6 0.8 3.4 0.4 248 29 306 255 21.9 0.1 22.3 21.7 06/15/2005 10:50:00 1.5 0.9 4.2 0.4 1.5 0.9 4.2 0.4 1.2 0.7 3.8 0.4 221 32 255 255 22 0 22.6 21.7 06/15/2005 11:00:00 2.3 1 4.2 0.4 2.3 1 4.6 0.4 1.9 0.8 3.8 0.4 231 29 216 255 22.3 0 22.6 22 06/15/2005 11:10:00 2.5 0.8 4.2 0.4 2.5 0.9 4.2 0.4 2 0.8 4.6 0.4 231 22 230 255 22.3 0 22.6 22 06/15/2005 11:20:00 2.5 1 4.6 0.4 2.3 1 4.6 0.4 2 1 4.6 0.4 260 45 269 255 22.1 0 22.3 22 06/15/2005 11:30:00 2.2 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.7 0.9 3.8 0.4 291 41 248 255 23 0.3 23.5 22.3 06/15/2005 11:40:00 2.2 0.8 3.8 0.4 2.1 0.9 3.8 0.4 1.6 0.8 3.8 0.4 260 56 345 255 23 0.1 23.5 22.9 06/15/2005 11:50:00 2.2 1 4.2 0.4 2.2 1 4.2 0.4 1.5 1 3.8 0.4 261 51 230 255 22.9 0.1 23.5 22.6 06/15/2005 12:00:00 2.9 1.2 6.5 0.4 2.8 1.3 6.8 0.4 2.3 1 6.1 0.4 277 56 317 255 23.3 0 23.5 23.2 06/15/2005 12:10:00 2.4 0.9 4.9 0.4 2.1 1 4.9 0.4 1.7 1 5.3 0.4 305 51 302 255 23.5 0.2 23.8 23.2 06/15/2005 12:20:00 2.7 1 5.3 0.4 2.6 1 5.3 0.4 2.3 1.1 4.9 0.4 240 29 242 255 23.6 0 24.1 23.5 06/15/2005 12:30:00 2.9 1 4.9 0.4 2.7 1 4.9 0.4 2.3 1.2 5.3 0.4 273 36 274 255 23.8 0 24.1 23.5 06/15/2005 12:40:00 3.2 1.4 8 0.4 3.2 1.3 8 0.4 2.7 1.2 6.5 0.4 295 36 301 255 23.5 0 23.8 23.5 06/15/2005 12:50:00 2.6 1.2 5.7 0.4 2.6 1.2 5.7 0.4 2.4 1.2 5.3 0.4 291 38 294 255 23.9 0.1 24.4 23.8 06/15/2005 13:00:00 2.4 1.3 6.1 0.4 2.2 1.3 6.1 0.4 1.8 1.2 5.3 0.4 293 47 330 255 24.7 0 25 24.1 06/15/2005 13:10:00 2.5 1.1 4.9 0.4 2.3 1.2 5.7 0.4 2.1 1.1 4.9 0.4 306 36 293 255 24.6 0 25 24.4 06/15/2005 13:20:00 2.4 1 4.6 0.4 2.3 1 4.6 0.4 1.9 1 4.9 0.4 305 47 297 255 25 0.1 25.3 24.7 06/15/2005 13:30:00 3.8 1.3 7.2 0.7 3.7 1.2 6.8 0.4 3 1.3 6.5 0.7 291 33 304 255 24.6 0.3 25.3 24.1 06/15/2005 13:40:00 3.2 1 5.3 1.5 3.2 1 5.3 1.1 2.7 0.9 4.9 0.7 301 26 305 255 24.9 0 25.3 24.7 06/15/2005 13:50:00 3.7 1.2 6.1 1.1 3.6 1.2 6.1 0.7 3.4 1.2 6.1 0.4 299 20 298 255 24.5 0.2 25 24.4 06/15/2005 14:00:00 4 0.9 6.8 1.1 3.9 0.9 6.5 1.1 3.4 1.1 6.5 0.7 290 28 303 255 24.8 0.3 25.3 24.1 06/15/2005 14:10:00 4.4 1.1 7.2 1.5 4.4 1.1 6.8 1.1 3.3 1.3 7.2 0.4 293 21 330 255 23.8 0 24.1 23.8 06/15/2005 14:20:00 3.7 1.2 5.7 0.7 3.6 1.2 6.1 0.4 3 1.3 5.7 0.4 301 32 308 255 24.4 0.2 24.7 23.8 06/15/2005 14:30:00 3.7 1.1 6.5 1.1 3.6 1.1 6.5 1.1 3 1.2 6.1 0.7 298 18 269 255 24.8 0.2 25.3 24.7 06/15/2005 14:40:00 3.2 1.1 5.7 0.7 3.1 1.1 5.7 0.4 2.5 1.2 5.3 0.4 283 33 276 255 25 0.3 25.6 24.4 06/15/2005 14:50:00 2.7 1.1 5.3 0.4 2.6 1.1 5.7 0.4 2.1 1.2 5.7 0.4 291 36 296 255 24.5 0 24.7 24.4 06/15/2005 15:00:00 3.3 1.1 5.7 1.5 3.2 1.1 6.1 1.1 2.7 1.3 5.7 0.4 292 22 298 255 24.5 0 24.7 24.4 06/15/2005 15:10:00 3.9 1 6.1 1.5 3.8 1.1 6.1 0.7 3.3 1.2 6.1 0.7 301 19 327 255 24.4 0.3 25 23.8 06/15/2005 15:20:00 3.8 1 6.5 0.7 3.7 1 6.5 0.4 3.2 1.2 6.1 0.4 296 21 298 255 24.4 0.4 25 23.8 06/15/2005 15:30:00 3.2 1.1 6.8 0.4 3.2 1.1 6.8 1.1 2.5 1 6.8 0.4 285 32 258 255 24.8 0 25 24.7 06/15/2005 15:40:00 2.8 0.9 5.7 0.7 2.7 0.9 5.3 0.7 2.1 1.1 5.7 0.4 297 26 279 255 24.6 0 25 24.4 06/15/2005 15:50:00 4.4 1 7.2 1.5 4.3 1 6.5 1.1 3.7 1.1 5.7 0.4 306 13 285 255 24.7 0 25 24.4 06/15/2005 16:00:00 3.1 1.2 6.8 0.7 3 1.2 6.8 0.7 2.4 1.2 6.5 0.4 292 32 281 255 24.9 0.2 25.3 24.7 06/15/2005 16:10:00 4.2 1 6.5 1.9 4.1 1 6.5 0.7 3.4 1.1 6.5 0.4 301 17 321 255 25.3 0 25.6 25 06/15/2005 16:20:00 3.4 1.1 5.7 1.1 3.4 1.1 5.7 1.1 2.8 1.2 5.3 0.4 283 29 255 255 25.5 0 25.6 25.6 06/15/2005 16:30:00 2.5 1.2 5.7 0.4 2.5 1.2 5.3 0.4 2.2 1.1 4.9 0.4 285 39 322 255 25.1 0.2 25.6 25 06/15/2005 16:40:00 3.4 1 6.5 1.1 3.4 1.1 6.8 0.7 2.5 1.1 5.7 0.4 267 27 261 255 24.9 0 25.3 24.7 06/15/2005 16:50:00 3.3 1.4 6.5 0.4 3.1 1.5 6.5 0.4 2.8 1.4 5.7 0.4 282 28 296 255 24.7 0 25 24.4 06/15/2005 17:00:00 2.8 1 5.3 0.7 2.7 1 5.3 0.4 2.2 1 5.3 0.4 265 24 252 255 24.2 0.2 24.7 23.8 06/15/2005 17:10:00 2.6 1.1 4.9 0.4 2.5 1.2 5.3 0.4 1.8 1.1 4.9 0.4 275 24 279 255 23.7 0 23.8 23.5 06/15/2005 17:20:00 3.1 1 5.7 0.7 3 1 5.3 0.4 2.3 1 5.3 0.4 281 22 294 255 23.3 0 23.8 23.2 06/15/2005 17:30:00 3.3 1.1 5.7 1.1 3.2 1.1 5.7 0.7 2.7 1 5.3 0.7 298 22 290 255 23 0.1 23.5 22.9 06/15/2005 17:40:00 3.4 1 5.7 1.1 3.4 1 5.7 1.1 2.7 0.9 5.3 0.7 281 21 292 255 22.7 0 23.2 22.3 06/15/2005 17:50:00 2.5 1.1 5.3 0.7 2.5 1.1 5.7 0.4 1.8 1 4.9 0.4 272 18 253 255 22.2 0 22.9 22.3 06/15/2005 18:00:00 2.1 1 4.2 0.4 2.2 1 4.2 0.4 1.6 0.8 3.4 0.4 265 24 263 255 22.1 0 22.9 22 06/15/2005 18:10:00 2.3 1 4.6 0.4 2.3 1 4.9 0.4 1.6 0.9 3.8 0.4 268 22 277 255 21.9 0 22.3 21.7 06/15/2005 18:20:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.7 3.4 0.4 256 20 268 255 21.7 0 22 21.7 06/15/2005 18:30:00 1.2 0.8 3.4 0.4 1.2 0.8 3.8 0.4 1 0.7 3.4 0.4 262 23 265 255 21.6 0 22 21.7 06/15/2005 18:40:00 1.9 1.1 4.6 0.4 1.9 1 4.6 0.4 1.4 0.8 3.4 0.4 235 22 286 255 21.7 0 22 21.7 06/15/2005 18:50:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 0.9 0.5 2.3 0.4 221 20 233 255 21.6 0 21.7 21.4 06/15/2005 19:00:00 1.9 0.6 3.8 0.7 1.8 0.7 3.4 0.4 1.4 0.7 3.4 0.4 224 17 235 255 21.4 0 21.7 21.1 06/15/2005 19:10:00 1.5 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.1 0.7 3 0.4 248 11 212 255 21.3 0 21.7 21.1 06/15/2005 19:20:00 1 0.6 3 0.4 1 0.6 3 0.4 0.7 0.4 1.9 0.4 225 15 237 255 21 0.2 21.7 20.5 06/15/2005 19:30:00 1.2 0.5 2.3 0.4 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 223 10 225 255 20.6 0.1 21.1 20.5 06/15/2005 19:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.1 0.4 250 4 238 255 20.3 0.1 20.8 20 06/15/2005 19:50:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 224 30 252 255 19.8 0.3 20.5 19.4 06/15/2005 20:00:00 1.2 0.4 2.3 0.4 1.3 0.3 1.9 0.7 1.1 0.3 1.9 0.4 163 12 151 255 19.3 0 20 19.1 06/15/2005 20:10:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 104 15 116 255 19 0 19.4 18.8 06/15/2005 20:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 68 10 85 255 18.2 0.2 19.1 17.7 06/15/2005 20:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 62 0 62 255 17.3 0.1 18 16.8 06/15/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 72 7 255 255 16.8 0 16.8 16.8 06/15/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 0 255 255 16.6 0 16.8 16.6 06/15/2005 21:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 96 12 104 255 16.6 0 16.8 16.6 06/15/2005 21:10:00 1 0.8 2.6 0.4 0.9 0.8 2.6 0.4 0.8 0.5 2.3 0.4 31 79 312 255 16.6 0 16.8 16.6 06/15/2005 21:20:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 0.8 0.6 2.6 0.4 281 22 290 255 16.5 0 16.8 16.3 06/15/2005 21:30:00 1.8 0.6 3 0.4 1.8 0.7 3 0.4 1 0.6 2.6 0.4 246 10 255 255 16.5 0 16.8 16.6 06/15/2005 21:40:00 2.2 0.5 3.4 0.7 2.2 0.6 3.4 0.4 1.4 0.6 3 0.4 248 11 255 255 16.4 0 16.6 16.3 06/15/2005 21:50:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 1.1 1.4 0.6 3 0.4 252 8 253 255 16.2 0 16.6 16 06/15/2005 22:00:00 2.7 0.5 3.8 1.1 2.7 0.5 4.2 1.1 1.5 0.5 3 0.7 262 12 255 255 15.9 0.1 16.3 15.7 06/15/2005 22:10:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.1 1.7 0.6 3.8 0.4 272 13 285 255 15.5 0 15.7 15.5 06/15/2005 22:20:00 1.7 1 4.6 0.4 1.7 0.9 4.2 0.4 1 0.7 3 0.4 266 26 252 255 15.2 0 15.7 15.2 06/15/2005 22:30:00 3.1 0.7 4.9 1.5 3.1 0.7 4.9 1.1 1.9 0.5 3.4 0.7 273 13 280 255 15.2 0 15.7 15.2 06/15/2005 22:40:00 3 0.6 4.6 1.5 3 0.6 4.6 1.5 2 0.7 3.8 0.4 276 13 259 255 15 0 15.7 14.9 06/15/2005 22:50:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 2.2 0.8 4.6 0.4 277 15 283 255 14.9 0 15.2 14.6 06/15/2005 23:00:00 2.8 0.8 4.6 1.1 2.9 0.8 5.7 0.4 1.8 0.8 4.2 0.4 266 15 265 255 14.9 0 15.5 14.9 06/15/2005 23:10:00 2.8 0.6 4.2 1.5 2.7 0.6 4.2 1.5 1.7 0.7 3.8 0.4 247 14 255 255 14.9 0 15.2 14.6 06/15/2005 23:20:00 1.7 0.7 3.4 0.4 1.6 0.8 3.4 0.4 0.9 0.6 2.6 0.4 239 13 261 255 14.5 0.1 15.2 14.1 06/15/2005 23:30:00 1.7 0.4 2.6 1.1 1.7 0.4 2.6 0.7 0.8 0.5 2.3 0.4 246 8 250 255 14.1 0.1 14.6 13.8 06/15/2005 23:40:00 1.8 0.4 3 1.1 1.8 0.4 3 0.7 0.8 0.4 1.9 0.4 259 6 270 255 13.8 0 14.6 13.5 06/15/2005 23:50:00 1.3 0.7 3 0.4 1.2 0.7 3.4 0.4 0.6 0.4 2.3 0.4 261 17 284 255 13.5 0.1 13.8 13.3 06/16/2005 00:00:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 250 7 272 255 13.4 0 13.8 13.3 06/16/2005 00:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 248 0 249 255 13.3 0 13.5 13.3 06/16/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 248 0 255 255 13.3 0 13.8 13 06/16/2005 00:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 248 0 249 255 13.3 0 13.5 13 06/16/2005 00:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 310 17 249 255 13.1 0.1 13.5 13 06/16/2005 00:50:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 278 26 263 255 13.1 0.1 13.5 13 06/16/2005 01:00:00 2 0.6 3.8 0.4 2 0.7 3.8 0.4 1.1 0.6 3.4 0.4 252 9 255 255 13.1 0.2 13.5 12.7 06/16/2005 01:10:00 2.7 0.4 4.2 1.5 2.8 0.4 3.8 1.9 1.6 0.4 3 0.7 236 10 244 255 12.9 0.1 13.3 12.7 06/16/2005 01:20:00 2.7 0.5 3.8 1.1 2.7 0.5 3.8 1.1 1.6 0.4 2.6 0.7 227 8 222 255 12.8 0 13.3 12.7 06/16/2005 01:30:00 2.3 0.4 3.4 1.5 2.3 0.4 3 1.5 1.4 0.4 2.3 0.4 226 9 244 255 12.7 0 13 12.5 06/16/2005 01:40:00 2.1 0.2 2.6 1.9 2.1 0.2 2.6 1.5 1.5 0.3 1.9 0.7 198 11 217 255 12.5 0 13 12.5 06/16/2005 01:50:00 1.8 0.5 2.6 0.7 2 0.3 2.6 1.5 1.5 0.3 2.3 0.7 164 15 190 255 12.3 0 12.5 12.2 06/16/2005 02:00:00 1 0.8 2.6 0.4 1 0.8 2.6 0.4 0.8 0.5 2.3 0.4 87 86 149 255 12.1 0 12.5 11.9 06/16/2005 02:10:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 337 43 29 255 11.9 0 12.2 11.7 06/16/2005 02:20:00 1.1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1 0.4 1.5 0.4 57 18 68 255 11.7 0 11.9 11.7 06/16/2005 02:30:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 61 9 44 255 11.6 0 12.2 11.4 06/16/2005 02:40:00 0.8 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.5 0.4 46 5 66 255 11.4 0.1 11.9 11.4 06/16/2005 02:50:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.5 2.3 0.4 61 3 69 255 11.3 0 11.9 11.1 06/16/2005 03:00:00 1.1 0.3 1.9 0.7 1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 84 15 60 255 11.1 0.1 11.7 10.9 06/16/2005 03:10:00 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.6 0.3 1.1 0.4 81 8 85 255 11 0 11.1 10.9 06/16/2005 03:20:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.7 0.4 1.5 0.4 99 8 96 255 11.1 0 11.1 11.1 06/16/2005 03:30:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.7 0.4 1.9 0.4 105 6 109 255 10.9 0.1 11.1 10.6 06/16/2005 03:40:00 1.1 0.3 1.9 0.4 1 0.3 1.5 0.4 0.5 0.3 1.5 0.4 107 0 107 255 10.8 0 11.1 10.6 06/16/2005 03:50:00 1.7 0.3 2.3 0.7 1.5 0.4 2.3 0.4 0.6 0.3 1.5 0.4 109 7 106 255 10.7 0.1 10.9 10.6 06/16/2005 04:00:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.7 0.4 1.9 0.4 98 7 90 255 10.7 0 10.9 10.6 06/16/2005 04:10:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.5 0.2 1.1 0.4 74 13 90 255 10.7 0 10.9 10.6 06/16/2005 04:20:00 2.5 0.3 3.4 1.5 2.4 0.3 3.4 1.5 1.3 0.5 2.6 0.4 99 10 96 255 10.6 0 10.9 10.6 06/16/2005 04:30:00 2.8 0.4 3.4 1.9 2.8 0.4 3.4 1.9 1.9 0.4 3 0.7 99 6 95 255 10.9 0 11.1 10.6 06/16/2005 04:40:00 2.3 0.4 3 1.1 2.3 0.4 3.4 1.1 1.3 0.4 2.6 0.4 103 11 90 255 11.4 0 11.7 11.1 06/16/2005 04:50:00 1.9 0.3 2.6 1.1 1.7 0.3 2.6 0.7 0.9 0.4 1.9 0.4 110 12 101 255 11.7 0 11.9 11.7 06/16/2005 05:00:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.6 0.3 1.5 0.4 106 10 113 255 12.4 0.3 13.3 11.9 06/16/2005 05:10:00 0.9 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.5 0.4 109 15 93 255 13.3 0 13.8 12.7 06/16/2005 05:20:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 92 6 99 255 13.6 0.2 14.6 13.3 06/16/2005 05:30:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 62 17 57 255 14.3 0.2 14.9 13.8 06/16/2005 05:40:00 1.4 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.4 1.9 0.4 101 10 91 255 14.6 0.2 15.2 14.4 06/16/2005 05:50:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 89 12 111 255 15.5 0.3 16.3 14.9 06/16/2005 06:00:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 1.2 0.6 3 0.4 82 20 95 255 16.1 0 16.6 16 06/16/2005 06:10:00 2.3 0.4 3.4 1.1 2.3 0.4 3 1.5 2 0.5 3 0.7 92 9 90 255 16.1 0 16.8 16 06/16/2005 06:20:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 1.4 0.6 2.6 0.4 85 13 101 255 16.4 0.3 16.8 16 06/16/2005 06:30:00 1.7 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1.5 0.5 2.6 0.4 66 20 80 255 16.9 0.1 17.1 16.8 06/16/2005 06:40:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 38 18 17 255 17.6 0 17.7 17.1 06/16/2005 06:50:00 1.5 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.3 0.4 2.3 0.4 65 28 43 255 17.8 0 18.2 17.7 06/16/2005 07:00:00 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 69 36 93 255 17.9 0.1 18.5 17.7 06/16/2005 07:10:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 31 16 10 255 18.5 0.3 19.4 18 06/16/2005 07:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 20 13 17 255 18 0.2 18.8 17.7 06/16/2005 07:30:00 1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.5 0.4 351 22 339 255 18.8 0.2 19.7 18.2 06/16/2005 07:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 4 27 318 255 19.6 0.2 20.3 19.1 06/16/2005 07:50:00 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 24 16 9 255 19.5 0 20 19.4 06/16/2005 08:00:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 29 15 8 255 19.5 0 19.7 19.4 06/16/2005 08:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.3 0.4 1.3 0.5 2.3 0.4 20 19 34 255 19.8 0 20 19.7 06/16/2005 08:20:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 2.6 0.4 17 26 3 255 19.7 0.1 20 19.4 06/16/2005 08:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 11 20 7 255 20 0 20.3 19.4 06/16/2005 08:40:00 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.7 0.4 1.9 0.4 65 58 58 255 20 0 20.5 20 06/16/2005 08:50:00 1.1 0.6 2.3 0.4 1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 38 38 0 255 20.5 0.1 20.8 20 06/16/2005 09:00:00 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 1.1 0.5 2.3 0.4 110 51 71 255 20.5 0 20.8 20.5 06/16/2005 09:10:00 0.9 0.6 3.4 0.4 0.9 0.6 3.4 0.4 0.9 0.7 3 0.4 6 82 352 255 21.1 0.3 21.7 20.5 06/16/2005 09:20:00 1.3 0.7 2.6 0.4 1.2 0.7 3 0.4 1.1 0.7 3 0.4 336 64 239 255 21.6 0 21.7 21.1 06/16/2005 09:30:00 1.2 0.6 3 0.4 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 266 72 258 255 21.9 0 22.3 21.7 06/16/2005 09:40:00 1.1 0.7 3 0.4 1 0.7 3 0.4 1.2 0.8 3 0.4 262 86 254 255 21.9 0.2 22.3 21.4 06/16/2005 09:50:00 1.7 0.8 3.8 0.4 1.6 0.9 3.8 0.4 1.4 0.8 3.8 0.4 277 69 277 255 21.9 0.1 22.6 21.7 06/16/2005 10:00:00 1.5 0.9 3.8 0.4 1.4 0.9 3.4 0.4 1.2 0.7 3 0.4 277 47 325 255 22.4 0.2 22.9 22 06/16/2005 10:10:00 1.6 1.1 4.2 0.4 1.5 1.1 4.2 0.4 1.3 0.9 3.4 0.4 268 56 315 255 22.7 0 23.2 22.3 06/16/2005 10:20:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.5 0.8 3.8 0.4 297 66 235 255 22.7 0.2 23.5 22.3 06/16/2005 10:30:00 2.2 1.2 5.3 0.4 2.3 1.2 5.7 0.4 1.7 1 4.9 0.4 229 53 257 255 23 0.1 23.2 22.9 06/16/2005 10:40:00 3 0.9 6.1 0.7 2.9 1 5.7 0.7 2.6 1 5.3 0.4 262 16 285 255 22.4 0.2 22.9 22 06/16/2005 10:50:00 1.7 1 3.8 0.4 1.6 1 3.8 0.4 1.4 0.8 3.4 0.4 270 27 261 255 22.1 0.4 22.9 21.4 06/16/2005 11:00:00 2.8 0.7 4.6 1.1 2.8 0.7 4.6 1.1 2.3 0.6 4.2 1.1 221 21 239 255 22.4 0.4 22.9 21.4 06/16/2005 11:10:00 1.9 0.8 3.4 0.4 1.9 0.8 3.8 0.4 1.6 0.8 3.8 0.4 223 28 214 255 23.2 0.2 23.8 22.6 06/16/2005 11:20:00 2.3 0.6 4.2 0.7 2.2 0.7 4.2 0.7 2.1 0.5 3.8 1.1 233 28 250 255 23 0.2 23.5 22.6 06/16/2005 11:30:00 1.8 1 3.8 0.4 1.7 1 4.2 0.4 1.6 0.9 4.2 0.4 253 49 301 255 23 0.2 23.5 22.6 06/16/2005 11:40:00 2.7 0.7 4.9 1.1 2.7 0.7 4.9 1.1 2.2 0.7 4.2 0.7 221 22 191 255 22.7 0.3 23.5 22.3 06/16/2005 11:50:00 2.1 0.9 4.2 0.4 2 0.9 4.2 0.4 1.8 0.8 3.8 0.4 267 38 261 255 23.1 0.2 23.8 22.6 06/16/2005 12:00:00 1.7 0.8 3.8 0.4 1.6 0.8 4.2 0.4 1.4 0.7 3 0.4 261 82 230 255 23.5 0.4 24.1 22.6 06/16/2005 12:10:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.4 2.3 0.4 86 72 214 255 24.3 0 24.7 23.8 06/16/2005 12:20:00 2.4 1.2 5.7 0.4 2.2 1.1 6.1 0.4 1.9 1.2 5.3 0.4 301 35 292 255 24.6 0 25 24.4 06/16/2005 12:30:00 3 1.1 6.5 0.4 2.8 1.1 6.1 0.4 2.4 1 5.7 0.4 275 49 266 255 24.4 0.3 25 23.8 06/16/2005 12:40:00 2.9 1 5.3 0.4 2.8 1 5.3 0.4 2.4 1.1 5.7 0.4 270 41 283 255 24.9 0 25.3 25 06/16/2005 12:50:00 3 1.2 6.8 0.7 2.9 1.2 6.1 0.4 2.6 1.1 6.5 0.4 284 35 251 255 25 0 25.3 25 06/16/2005 13:00:00 3.4 1.1 6.8 0.4 3.4 1.2 7.2 0.4 2.9 1.2 6.1 0.4 282 28 272 255 25 0.1 25.3 24.7 06/16/2005 13:10:00 3.3 1.1 6.5 0.4 3.3 1.1 6.5 0.4 2.8 1.2 5.7 0.4 286 32 281 255 25.1 0 25.6 25 06/16/2005 13:20:00 3.5 1 6.1 1.1 3.5 1 6.1 1.1 2.7 1 5.3 0.7 291 26 300 255 25.5 0.2 25.9 25 06/16/2005 13:30:00 3.8 1.5 6.5 0.4 3.7 1.5 6.5 0.4 3.1 1.4 6.1 0.4 299 22 297 255 25 0 25.3 25 06/16/2005 13:40:00 3.4 1.3 6.8 0.4 3.3 1.3 6.5 0.4 3 1.5 6.5 0.4 283 23 312 255 25.2 0.1 25.6 25 06/16/2005 13:50:00 2.9 1.2 6.5 0.4 2.9 1.2 6.1 0.4 2.5 1 5.7 0.4 271 27 269 255 25.5 0.1 25.9 25.3 06/16/2005 14:00:00 3.5 1.2 6.5 0.4 3.4 1.2 6.1 0.7 2.9 1.3 6.1 0.4 280 32 282 255 25.7 0 26.2 25.6 06/16/2005 14:10:00 3.8 1.4 7.6 0.7 3.7 1.5 8 0.4 2.8 1.4 6.1 0.4 294 39 259 255 26 0 26.2 25.9 06/16/2005 14:20:00 4 1 6.5 1.5 3.8 1 6.5 1.5 3.3 1 5.7 0.4 278 32 264 255 25.7 0.1 26.5 25.3 06/16/2005 14:30:00 3.2 1 6.1 1.1 3.1 1.1 6.1 1.1 2.5 1.1 5.3 0.4 289 23 301 255 25.7 0.3 26.2 25.3 06/16/2005 14:40:00 4.1 1.1 6.8 1.1 4.1 1.1 6.8 1.5 3.5 1.1 6.8 0.7 297 22 303 255 25.7 0 26.2 25.6 06/16/2005 14:50:00 3.7 1.2 6.8 1.1 3.5 1.2 6.5 0.7 3.1 1.3 6.1 0.4 288 26 297 255 26 0 26.2 25.6 06/16/2005 15:00:00 3.2 0.9 5.3 0.7 3.1 0.9 5.3 1.1 2.7 1 5.7 0.4 288 29 294 255 25.8 0 26.2 25.6 06/16/2005 15:10:00 3.5 1.6 6.8 0.4 3.4 1.7 6.8 0.4 3 1.3 6.8 0.4 279 24 304 255 26.1 0 26.2 25.9 06/16/2005 15:20:00 2.7 1.1 5.7 0.4 2.6 1.1 5.3 0.4 2.3 1.1 5.7 0.4 278 51 304 255 26.3 0 26.5 26.2 06/16/2005 15:30:00 3.3 0.9 6.5 0.4 3.3 0.9 6.1 0.4 2.6 1 6.1 0.4 271 24 298 255 26 0 26.5 25.9 06/16/2005 15:40:00 3.7 1.1 6.1 1.1 3.6 1.2 6.1 0.7 2.9 1.3 5.7 0.4 285 33 307 255 26.3 0 26.5 26.2 06/16/2005 15:50:00 3.2 1 6.5 1.5 3.1 1 6.5 1.1 2.5 1 5.7 0.7 284 27 312 255 26.4 0 26.5 26.2 06/16/2005 16:00:00 3.2 1 5.7 0.4 3.2 1 5.7 0.4 2.6 0.9 4.9 0.4 274 22 255 255 26.1 0.2 26.5 25.6 06/16/2005 16:10:00 2.9 1 5.3 0.4 2.8 1 5.3 0.4 2.3 0.9 4.9 0.4 281 28 277 255 25.4 0 25.9 25.3 06/16/2005 16:20:00 2.6 1.1 4.9 0.4 2.5 1.2 4.9 0.4 2.3 1.1 4.9 0.4 277 29 287 255 26 0 26.2 25.6 06/16/2005 16:30:00 2.3 0.8 4.6 0.7 2.3 0.8 4.6 0.4 2 0.8 3.8 0.4 280 22 256 255 25.9 0 26.2 25.6 06/16/2005 16:40:00 3.2 0.6 5.3 1.5 3.2 0.7 5.3 1.5 2.5 1 4.6 0.7 298 22 273 255 26 0 26.2 25.9 06/16/2005 16:50:00 2.4 0.9 4.6 0.7 2.4 1 4.6 0.4 2.2 0.8 3.8 0.4 291 24 288 255 25.5 0 25.9 25.3 06/16/2005 17:00:00 2.6 1.3 5.3 0.4 2.5 1.3 5.3 0.4 2.1 1.2 5.3 0.4 285 27 265 255 25.6 0 25.6 25.6 06/16/2005 17:10:00 3.1 0.8 5.3 0.7 3.1 0.8 5.3 0.7 2.7 0.8 4.6 0.4 288 19 287 255 25.6 0 25.9 25.3 06/16/2005 17:20:00 3.1 1 5.7 0.4 3 1 5.3 0.4 2.7 1 5.7 0.7 287 18 267 255 25.3 0 25.6 25.3 06/16/2005 17:30:00 2.6 1 4.6 0.4 2.5 1 4.6 0.4 2.4 1 4.6 0.4 271 36 302 255 25 0 25.3 25 06/16/2005 17:40:00 3.5 0.9 6.1 0.7 3.4 1 6.1 0.7 2.9 1.1 4.9 0.4 292 27 315 255 24.9 0 25.3 25 06/16/2005 17:50:00 3.7 0.9 5.7 1.5 3.7 0.9 5.7 1.1 3.1 1 6.1 1.5 285 24 297 255 24.9 0 25 25 06/16/2005 18:00:00 3.1 0.9 5.7 0.7 3 0.9 5.3 0.7 2.7 1 5.3 0.7 269 19 297 255 24.8 0 25 24.7 06/16/2005 18:10:00 2.6 1 4.6 0.4 2.5 1 4.6 0.4 2.1 0.8 4.2 0.4 291 24 297 255 24.6 0 25 24.4 06/16/2005 18:20:00 3.6 0.7 5.3 1.5 3.5 0.8 5.7 1.5 3.1 0.9 5.3 1.1 276 17 267 255 24.1 0.1 24.7 24.1 06/16/2005 18:30:00 2.3 1 4.2 0.4 2.2 1 4.6 0.4 1.7 0.9 4.2 0.4 277 20 267 255 23.9 0 24.1 23.8 06/16/2005 18:40:00 2.7 1.1 4.9 0.4 2.6 1 4.6 0.4 2.2 1 4.9 0.4 288 19 312 255 23.8 0 24.1 23.8 06/16/2005 18:50:00 3.3 0.7 4.9 1.5 3.3 0.7 4.9 1.5 2.8 0.7 4.9 1.1 283 15 265 255 23.5 0 23.8 23.5 06/16/2005 19:00:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 0.7 2.1 1 4.6 0.4 289 21 287 255 23.4 0 23.8 23.5 06/16/2005 19:10:00 2.2 1 4.6 0.4 2.2 1.1 4.6 0.4 1.6 1 3.8 0.4 280 27 286 255 23.4 0 23.8 23.5 06/16/2005 19:20:00 3.3 1 5.3 0.7 3.1 1 5.7 0.4 2.6 1 4.9 0.4 292 16 295 255 23.1 0.1 23.8 22.9 06/16/2005 19:30:00 3.4 0.8 5.3 1.9 3.3 0.8 5.3 0.7 2.7 1 4.9 0.7 290 17 302 255 22.7 0 23.5 22.6 06/16/2005 19:40:00 3.1 1.1 6.5 0.7 3.1 1.1 6.1 0.7 2.6 1.1 6.1 0.4 282 22 301 255 22.4 0 22.9 22.3 06/16/2005 19:50:00 2.9 1 5.7 0.4 2.8 1.1 5.3 0.4 2.4 1 4.6 0.4 290 19 298 255 22.2 0 22.6 22 06/16/2005 20:00:00 2.6 1.1 5.3 0.4 2.6 1.1 5.7 0.4 2 1 4.2 0.4 272 24 300 255 22.1 0 22.3 21.7 06/16/2005 20:10:00 2.3 0.8 4.6 0.4 2.2 0.8 4.2 0.4 1.8 0.9 3.8 0.4 277 24 262 255 21.9 0.2 22.3 21.4 06/16/2005 20:20:00 1.7 0.8 3.8 0.4 1.7 0.8 3.4 0.4 1.3 0.7 3.8 0.4 269 22 259 255 21.5 0 22 21.1 06/16/2005 20:30:00 1.3 0.8 3 0.4 1.3 0.7 3 0.4 1.1 0.7 2.6 0.4 273 19 286 255 21.2 0 21.7 20.8 06/16/2005 20:40:00 1.4 0.7 3.4 0.4 1.4 0.7 3.4 0.4 0.8 0.5 2.3 0.4 248 22 260 255 20.5 0.2 21.1 20.3 06/16/2005 20:50:00 2.6 0.7 4.2 1.5 2.6 0.8 4.6 1.1 1.9 0.6 3.8 0.4 247 13 252 255 19.9 0.1 20.5 19.7 06/16/2005 21:00:00 2.4 0.8 4.9 0.7 2.4 0.8 4.6 0.4 1.5 0.8 4.2 0.4 232 17 243 255 19.6 0.1 20.3 19.4 06/16/2005 21:10:00 2.8 0.7 4.9 1.1 2.8 0.7 4.9 1.1 1.8 0.8 3.8 0.4 245 22 255 255 19.4 0 20 19.4 06/16/2005 21:20:00 2.5 0.6 4.2 1.1 2.5 0.6 4.2 0.7 1.8 0.6 3.8 0.7 235 15 233 255 19 0 19.4 18.8 06/16/2005 21:30:00 2.5 0.6 3.8 1.1 2.5 0.6 4.2 1.1 1.6 0.6 3.4 0.4 228 15 216 255 18.7 0.1 19.1 18.5 06/16/2005 21:40:00 2 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.2 0.6 3.4 0.4 244 13 250 255 18.2 0 18.5 18 06/16/2005 21:50:00 1 0.5 2.3 0.4 0.9 0.5 2.6 0.4 0.5 0.3 1.9 0.4 251 17 251 255 17.7 0.2 18 17.1 06/16/2005 22:00:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 309 23 294 255 17.1 0.1 17.4 16.8 06/16/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 16.4 0.2 16.8 16.3 06/16/2005 22:20:00 0.7 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 347 0 347 255 15.9 0.1 16.3 15.7 06/16/2005 22:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 347 0 347 255 15.5 0 16 15.2 06/16/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 15.1 0 15.5 15.2 06/16/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 14.8 0 15.2 14.6 06/16/2005 23:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 347 255 14.4 0.1 14.9 14.1 06/16/2005 23:10:00 0.8 0.2 1.1 0.4 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 347 0 347 255 14.1 0.1 14.6 13.8 06/16/2005 23:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 347 0 347 255 13.7 0 14.1 13.5 06/16/2005 23:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 347 0 346 255 13.5 0 13.8 13.3 06/16/2005 23:40:00 0.5 0.2 1.1 0.4 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 347 0 347 255 13.4 0 13.8 13.3 06/16/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 13.1 0 13.5 12.7 06/17/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 12.9 0 13.3 12.7 06/17/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 12.7 0 12.7 12.5 06/17/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 255 255 12.5 0 12.7 12.5 06/17/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 347 0 255 255 12.5 0.1 12.7 12.2 06/17/2005 00:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 2.3 0.4 35 61 142 255 12.3 0 12.7 12.2 06/17/2005 00:50:00 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.7 0.9 0.5 2.3 0.4 126 7 139 255 12.1 0 12.7 11.9 06/17/2005 01:00:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 123 6 116 255 12.1 0 12.5 11.9 06/17/2005 01:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 137 6 127 255 12.1 0.1 12.5 11.9 06/17/2005 01:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 136 13 140 255 12 0.2 12.5 11.9 06/17/2005 01:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 89 0 89 255 11.8 0.1 12.2 11.7 06/17/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 255 255 11.7 0 12.2 11.4 06/17/2005 01:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 89 0 89 255 11.5 0 11.9 11.4 06/17/2005 02:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 89 0 89 255 11.3 0.1 11.7 11.4 06/17/2005 02:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 89 255 11.3 0.1 11.7 11.4 06/17/2005 02:20:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 89 0 89 255 11.2 0 11.7 11.1 06/17/2005 02:30:00 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.6 0.2 1.1 0.4 89 0 89 255 11.1 0 11.7 11.1 06/17/2005 02:40:00 1.5 0.2 2.3 0.7 1.4 0.2 1.9 0.7 1.1 0.3 1.9 0.4 113 11 127 255 11 0 11.7 10.9 06/17/2005 02:50:00 1.9 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.3 0.4 2.3 0.4 122 11 140 255 10.7 0 11.1 10.6 06/17/2005 03:00:00 1.5 0.6 2.6 0.4 1.3 0.7 2.6 0.4 0.7 0.4 2.3 0.4 85 17 105 255 10.6 0 11.1 10.6 06/17/2005 03:10:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 68 4 70 255 10.5 0 10.9 10.6 06/17/2005 03:20:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.1 0.4 69 0 69 255 10.5 0 10.6 10.3 06/17/2005 03:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 69 0 69 255 10.3 0 10.6 10.3 06/17/2005 03:40:00 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 69 0 69 255 10.2 0 10.6 10.3 06/17/2005 03:50:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.7 0.9 0.3 1.5 0.4 69 0 69 255 10.2 0 10.6 10.3 06/17/2005 04:00:00 1.7 0.2 2.3 1.1 1.6 0.3 2.3 1.1 0.6 0.3 1.5 0.4 93 12 92 255 10.3 0 10.6 10.3 06/17/2005 04:10:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.8 0.3 1.5 0.4 112 9 109 255 10.3 0 10.6 10.3 06/17/2005 04:20:00 1.8 0.5 2.6 0.7 1.7 0.5 2.6 0.4 1.2 0.3 1.9 0.7 120 11 114 255 10.2 0 10.3 10.1 06/17/2005 04:30:00 2 0.3 2.6 1.1 1.9 0.3 2.6 0.7 1.1 0.3 1.9 0.4 109 5 115 255 10.3 0 10.6 10.3 06/17/2005 04:40:00 2.3 0.3 3 1.1 2.2 0.3 3 1.1 1.4 0.4 2.3 0.4 109 7 119 255 10.7 0 10.9 10.6 06/17/2005 04:50:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.5 1.9 0.4 3 0.7 111 10 106 255 11.1 0 11.4 10.9 06/17/2005 05:00:00 2.8 0.5 4.2 1.9 2.8 0.5 3.8 1.5 2 0.6 3.8 0.7 107 9 108 255 11.9 0.3 12.7 11.4 06/17/2005 05:10:00 2.6 0.5 4.2 1.5 2.5 0.5 3.8 1.1 1.8 0.6 3.4 0.7 110 12 116 255 13.1 0.3 13.8 12.5 06/17/2005 05:20:00 1.6 0.8 3.8 0.4 1.4 0.8 3.4 0.4 0.9 0.6 3 0.4 104 13 74 255 13.9 0.2 14.6 13.5 06/17/2005 05:30:00 1.6 0.7 3 0.4 1.5 0.8 3 0.4 1.2 0.7 3 0.4 100 22 95 255 14.4 0 14.9 14.4 06/17/2005 05:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.3 1.5 0.4 75 12 64 255 14.8 0.1 15.5 14.6 06/17/2005 05:50:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 98 22 106 255 15.2 0.1 15.7 15.2 06/17/2005 06:00:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 134 19 91 255 16.1 0.2 16.8 15.7 06/17/2005 06:10:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 108 21 95 255 16.4 0 16.8 16.3 06/17/2005 06:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 117 0 117 255 16.9 0.2 17.1 16.6 06/17/2005 06:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 92 6 91 255 17.8 0.4 18.5 17.1 06/17/2005 06:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 123 21 133 255 18.7 0 19.1 18.5 06/17/2005 06:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 99 16 84 255 18.7 0.1 19.4 18.2 06/17/2005 07:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 26 15 18 255 19 0.1 19.4 18.5 06/17/2005 07:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 20 36 62 255 19 0.3 19.7 18.5 06/17/2005 07:20:00 0.9 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.9 0.4 2.3 0.4 29 16 12 255 19.2 0.1 19.7 18.8 06/17/2005 07:30:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 352 16 29 255 19.1 0.1 19.7 18.8 06/17/2005 07:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.1 0.4 20 17 8 255 19.7 0.2 20.5 19.4 06/17/2005 07:50:00 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 1 0.4 1.9 0.4 57 27 32 255 20.2 0 20.5 20 06/17/2005 08:00:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.7 0.4 1.9 0.4 57 29 30 255 20.2 0.2 20.8 20 06/17/2005 08:10:00 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.4 2.6 0.4 359 22 18 255 20.8 0 21.1 20.5 06/17/2005 08:20:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 349 17 348 255 21 0 21.7 20.8 06/17/2005 08:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.9 0.4 305 39 350 255 21.3 0.1 22 20.8 06/17/2005 08:40:00 0.9 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.9 0.4 1.9 0.4 34 24 66 255 21.3 0.1 21.7 21.1 06/17/2005 08:50:00 1.6 0.7 3 0.4 1.5 0.7 3 0.4 1.5 0.7 3 0.4 297 30 321 255 21.2 0 21.7 20.8 06/17/2005 09:00:00 1.8 0.8 4.2 0.4 1.6 0.8 4.6 0.4 1.3 0.7 3.4 0.4 321 49 308 255 21.3 0.3 22 20.8 06/17/2005 09:10:00 2.1 0.8 3.4 0.4 1.9 0.7 3.4 0.4 1.8 0.8 3.8 0.4 307 35 350 255 22 0.2 22.6 21.7 06/17/2005 09:20:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 293 49 306 255 21.9 0 22.3 21.7 06/17/2005 09:30:00 0.9 0.5 2.3 0.4 0.9 0.5 2.6 0.4 0.9 0.5 2.3 0.4 192 58 228 255 22.1 0.1 22.6 22 06/17/2005 09:40:00 1.5 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1.4 0.6 3.4 0.4 255 61 290 255 22.5 0 22.9 22.3 06/17/2005 09:50:00 2 0.9 4.2 0.4 1.9 0.9 4.2 0.4 1.5 0.8 3.8 0.4 309 38 255 255 22.9 0.2 23.5 22.3 06/17/2005 10:00:00 1.8 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.5 0.8 3.4 0.4 278 56 325 255 23 0 23.2 22.9 06/17/2005 10:10:00 1.3 0.8 3 0.4 1.3 0.8 3 0.4 1.3 0.7 3.4 0.4 206 53 265 255 23.1 0 23.5 22.9 06/17/2005 10:20:00 1.5 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.1 0.6 3 0.4 315 30 316 255 23.5 0 23.8 23.2 06/17/2005 10:30:00 2 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.9 0.7 3.4 0.4 304 27 300 255 23.8 0.1 24.1 23.5 06/17/2005 10:40:00 2.5 0.8 4.9 0.4 2.3 0.8 4.9 0.4 1.8 0.9 4.6 0.4 333 24 346 255 24.4 0 25 24.1 06/17/2005 10:50:00 2.7 0.8 4.2 0.4 2.5 0.7 3.8 0.4 2.5 0.9 4.6 0.7 328 17 323 255 24.2 0 24.7 24.1 06/17/2005 11:00:00 2.4 0.6 4.2 0.7 2.3 0.7 4.6 0.7 2 0.8 4.2 0.4 269 23 286 255 24.3 0 24.7 24.1 06/17/2005 11:10:00 1.6 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1 0.6 2.6 0.4 289 69 253 255 24.4 0.1 25 24.1 06/17/2005 11:20:00 2.2 0.7 4.2 0.4 2.1 0.7 4.6 0.4 1.9 0.8 3.8 0.4 311 29 324 255 24.8 0 25 24.7 06/17/2005 11:30:00 3.4 1 6.1 1.1 3.2 1 6.1 1.1 2.7 1 4.9 0.7 309 23 335 255 24.4 0 24.7 24.1 06/17/2005 11:40:00 2.4 0.7 4.2 0.4 2.2 0.8 4.2 0.4 1.9 0.7 4.2 0.4 315 32 333 255 24.7 0.2 25.3 24.4 06/17/2005 11:50:00 2.2 1 4.6 0.4 2.1 1 4.9 0.4 1.8 1 4.6 0.4 303 36 284 255 25 0.2 25.6 24.7 06/17/2005 12:00:00 2.7 1 4.9 0.4 2.5 1 4.9 0.4 2.1 1 4.6 0.4 320 27 328 255 25.1 0 25.6 25 06/17/2005 12:10:00 3.7 0.9 6.1 1.5 3.6 0.9 5.7 1.5 3 1.1 6.1 0.4 315 22 298 255 25.7 0 25.9 25.6 06/17/2005 12:20:00 2.7 0.7 4.6 1.1 2.6 0.7 4.6 0.7 2.4 0.9 4.6 0.4 305 16 306 255 25 0.1 25.6 25 06/17/2005 12:30:00 2.4 1 4.6 0.4 2.2 1 4.2 0.4 2.1 1 4.2 0.4 319 32 301 255 25 0.2 25.6 24.7 06/17/2005 12:40:00 2.3 0.8 4.2 0.4 2.1 0.8 3.8 0.4 2 0.9 4.2 0.4 295 49 299 255 25.5 0 25.6 25.3 06/17/2005 12:50:00 2 0.7 3.4 0.7 1.9 0.7 3.8 0.4 1.9 0.8 4.2 0.4 255 38 279 255 25.3 0 25.6 25 06/17/2005 13:00:00 2.3 1 4.6 0.4 2.3 1 4.2 0.4 2 1 4.2 0.4 259 32 284 255 25.7 0.2 26.2 25.3 06/17/2005 13:10:00 1.9 1 4.6 0.4 1.8 1 4.6 0.4 1.6 1 4.6 0.4 266 47 236 255 26.3 0 26.5 26.2 06/17/2005 13:20:00 2 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.7 0.8 3.4 0.4 230 53 307 255 26.2 0 26.5 26.2 06/17/2005 13:30:00 3.1 0.8 4.9 0.7 3 0.8 4.9 0.7 2.6 1 5.3 0.4 276 22 294 255 26 0 26.2 25.6 06/17/2005 13:40:00 2.6 0.9 5.3 0.4 2.6 1 4.6 0.4 2.2 1 4.9 0.4 274 28 254 255 26.3 0.1 26.8 26.2 06/17/2005 13:50:00 2.5 1.3 5.7 0.4 2.3 1.3 5.3 0.4 2 1.1 4.6 0.4 269 53 291 255 26.5 0 26.8 26.5 06/17/2005 14:00:00 3.6 1.1 6.5 0.7 3.5 1 5.7 0.4 3.2 1 5.7 0.7 288 20 257 255 26.3 0 26.5 26.2 06/17/2005 14:10:00 2.9 1.3 6.8 0.4 2.9 1.3 6.8 0.4 2.2 1.1 5.3 0.4 292 35 284 255 26.6 0.3 27.1 26.2 06/17/2005 14:20:00 2.8 1.2 6.5 0.4 2.7 1.2 6.1 0.4 2.4 1.2 5.7 0.4 299 35 290 255 27.1 0 27.4 26.5 06/17/2005 14:30:00 3.7 1 6.5 0.7 3.6 1 5.7 1.1 3 1.1 6.1 0.4 292 26 322 255 26.7 0 27.1 26.5 06/17/2005 14:40:00 2.9 1.1 6.5 0.4 2.8 1.1 7.2 0.4 2.3 1 6.5 0.4 281 41 304 255 26.8 0 27.1 26.5 06/17/2005 14:50:00 2.5 1 4.6 0.4 2.5 0.9 4.9 0.4 2 0.8 4.2 0.4 262 38 301 255 27 0.1 27.4 26.5 06/17/2005 15:00:00 3.2 1 5.7 1.1 3.2 1 5.3 1.1 2.7 1.1 5.7 0.7 269 29 302 255 26.9 0.1 27.4 26.5 06/17/2005 15:10:00 2.7 1 4.9 0.4 2.7 1.1 4.9 0.4 2.3 1 4.6 0.4 292 30 265 255 26.6 0 26.8 26.5 06/17/2005 15:20:00 3.2 1.3 6.1 0.4 3.1 1.3 5.7 0.4 2.7 1.2 5.7 0.4 279 29 288 255 26.6 0 26.8 26.5 06/17/2005 15:30:00 3.1 1.1 5.7 0.7 3.1 1.2 6.1 0.4 2.8 1.1 5.3 0.4 282 27 250 255 26.1 0 26.5 25.9 06/17/2005 15:40:00 2.9 1 5.3 0.4 2.8 1.1 5.7 0.4 2.4 1 5.3 0.4 298 35 297 255 26.5 0 26.8 26.2 06/17/2005 15:50:00 3 1.2 5.3 0.4 2.9 1.2 5.3 0.4 2.5 1.1 5.3 0.4 285 33 263 255 26.6 0.2 26.8 26.2 06/17/2005 16:00:00 3.2 1.3 6.1 0.4 3 1.5 6.1 0.4 2.5 1.3 5.7 0.4 295 38 297 255 26.6 0 26.8 26.2 06/17/2005 16:10:00 3.3 1 5.7 0.7 3.2 1.1 5.3 0.4 2.6 1.1 5.3 0.4 289 22 293 255 26.5 0 26.8 26.5 06/17/2005 16:20:00 3 1.2 5.3 0.4 2.9 1.3 5.7 0.4 2.5 1.1 4.9 0.4 281 26 286 255 26 0 26.5 25.9 06/17/2005 16:30:00 2.8 1 5.7 0.7 2.8 1 5.3 0.7 2.3 0.9 4.6 0.4 271 23 275 255 26 0 26.2 25.9 06/17/2005 16:40:00 2.4 1 5.3 0.4 2.3 1.1 5.7 0.4 1.9 0.9 4.6 0.4 264 30 255 255 26 0.1 26.5 25.9 06/17/2005 16:50:00 3 1 5.7 0.7 2.9 1 5.3 0.4 2.6 1.2 5.7 0.4 276 27 274 255 25.9 0 26.2 25.9 06/17/2005 17:00:00 3.3 0.9 4.9 1.1 3.2 0.9 4.9 0.7 2.6 1 4.9 0.4 288 23 293 255 25.3 0 25.9 25.3 06/17/2005 17:10:00 3.1 0.9 4.9 0.7 3 1 4.9 0.4 2.6 1 5.3 0.4 280 27 272 255 25 0 25.3 25 06/17/2005 17:20:00 3.6 0.8 5.3 1.1 3.5 0.8 5.3 1.1 3 1 5.3 0.7 290 18 289 255 24.8 0 25 24.7 06/17/2005 17:30:00 3.1 1.2 6.5 1.1 3.1 1.2 6.8 0.7 2.7 1.3 6.1 0.4 284 19 271 255 24.3 0.1 24.7 24.1 06/17/2005 17:40:00 3.3 0.8 5.3 1.5 3.2 0.9 5.3 1.5 2.7 0.9 4.9 0.7 292 17 280 255 24 0 24.1 23.8 06/17/2005 17:50:00 4.2 0.8 5.7 2.3 4.2 0.8 6.1 1.9 3.6 0.9 5.7 1.1 290 13 284 255 24 0 24.1 23.8 06/17/2005 18:00:00 3.2 1 5.3 0.7 3 1 5.3 0.7 2.7 1 5.3 0.4 276 26 296 255 23.8 0 23.8 23.5 06/17/2005 18:10:00 2.6 1.1 4.9 0.4 2.6 1.1 5.3 0.4 2.1 1 4.6 0.4 247 29 263 255 23.7 0 23.8 23.5 06/17/2005 18:20:00 3.3 0.8 5.3 1.5 3.2 0.8 5.3 1.1 2.4 0.9 4.9 0.4 253 17 267 255 23.6 0 23.8 23.5 06/17/2005 18:30:00 2.7 1 4.6 0.4 2.6 1.1 4.6 0.4 2.2 1.1 4.2 0.4 264 19 280 255 23.4 0 23.5 23.5 06/17/2005 18:40:00 3.6 1.3 6.5 0.4 3.6 1.3 6.5 0.4 2.7 1.3 5.7 0.4 258 24 278 255 23.3 0 23.5 23.2 06/17/2005 18:50:00 2.4 1.1 5.3 0.4 2.4 1.1 5.3 0.4 2 1 4.6 0.4 269 24 276 255 22.8 0 23.2 22.6 06/17/2005 19:00:00 3.5 0.9 5.7 1.5 3.4 0.9 5.7 1.1 2.8 1.1 5.3 0.4 269 15 277 255 22.3 0.2 22.9 22 06/17/2005 19:10:00 3.2 1.1 5.7 0.4 3.2 1.1 5.7 0.4 2.4 1 4.9 0.4 275 20 257 255 21.7 0 22 21.4 06/17/2005 19:20:00 2 0.9 4.6 0.4 2 0.8 4.2 0.4 1.3 0.8 3.8 0.4 273 22 267 255 21.4 0 21.7 21.1 06/17/2005 19:30:00 2 1.3 4.9 0.4 1.9 1.4 4.9 0.4 1.5 1 4.6 0.4 282 26 310 255 21.1 0 21.4 20.8 06/17/2005 19:40:00 3.6 1 6.8 1.1 3.5 1 7.2 1.5 2.8 1 5.7 0.4 269 21 269 255 20.6 0 21.1 20.3 06/17/2005 19:50:00 3.3 1.3 6.5 0.7 3.2 1.4 6.5 0.4 2.4 1.2 5.3 0.4 263 26 281 255 20 0.2 20.5 19.4 06/17/2005 20:00:00 2.9 1.1 6.5 0.4 2.8 1.1 5.7 0.4 2 1.1 5.3 0.4 254 27 263 255 19.5 0.1 20 19.1 06/17/2005 20:10:00 3.1 1 5.7 0.7 3 1 5.7 0.7 2.3 0.9 4.6 0.4 264 22 255 255 19 0 19.7 18.8 06/17/2005 20:20:00 3.4 0.9 5.7 1.1 3.5 0.9 6.1 1.1 2.7 1 5.3 0.7 262 22 271 255 18.6 0 19.1 18.2 06/17/2005 20:30:00 3.7 1.6 7.6 0.4 3.6 1.6 8 0.4 2.7 1.4 6.5 0.4 265 28 263 255 18.1 0 18.8 17.7 06/17/2005 20:40:00 3.9 1.3 7.2 0.4 3.9 1.3 6.8 0.7 2.9 1.4 6.8 0.4 263 21 255 255 17.5 0.2 18.2 17.1 06/17/2005 20:50:00 3.4 1.3 7.2 0.7 3.4 1.3 7.2 0.4 2.7 1.1 5.7 0.4 266 22 256 255 16.9 0.1 17.1 16.8 06/17/2005 21:00:00 2.7 1.2 5.7 0.4 2.6 1.3 5.7 0.4 1.9 0.9 4.9 0.4 261 22 258 255 16.6 0 16.8 16.3 06/17/2005 21:10:00 2.6 1.3 5.7 0.4 2.6 1.3 5.7 0.4 1.9 1 4.9 0.4 265 32 303 255 16.4 0 16.6 16.3 06/17/2005 21:20:00 2.2 0.9 4.6 0.4 2.2 0.9 4.6 0.4 1.6 0.8 4.2 0.4 257 19 266 255 16.3 0 16.6 16.3 06/17/2005 21:30:00 1.7 0.9 4.6 0.4 1.7 0.8 4.6 0.4 1.3 0.7 3 0.4 262 22 249 255 16.1 0 16.3 16 06/17/2005 21:40:00 2.4 0.9 4.9 0.4 2.4 0.9 4.9 0.4 1.7 0.9 4.2 0.4 251 19 252 255 15.9 0 16.3 15.7 06/17/2005 21:50:00 2.1 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.2 0.6 3 0.4 236 12 250 255 15.8 0 16.3 15.7 06/17/2005 22:00:00 3 0.8 5.3 1.5 2.9 0.9 5.7 1.1 2.1 0.8 4.2 0.7 236 17 225 255 15.5 0 16 15.2 06/17/2005 22:10:00 2.2 0.6 4.2 0.4 2.2 0.7 3.8 0.7 1.3 0.5 2.6 0.4 219 13 222 255 15.5 0 15.7 15.5 06/17/2005 22:20:00 2 0.4 3 0.7 2 0.3 3 1.1 1.3 0.4 2.3 0.4 192 13 193 255 15 0 15.5 14.6 06/17/2005 22:30:00 1.1 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1 0.4 1.5 0.4 179 6 195 255 14.6 0 14.9 14.4 06/17/2005 22:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 165 28 176 255 14.2 0 14.6 14.1 06/17/2005 22:50:00 0.8 0.2 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 37 19 27 255 14 0 14.4 13.8 06/17/2005 23:00:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 31 9 27 255 13.8 0 14.4 13.5 06/17/2005 23:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 25 17 53 255 13.6 0 13.8 13.5 06/17/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 15 0 255 255 13.5 0 13.8 13.3 06/17/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 13.5 0.1 13.8 13.3 06/17/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 13.4 0 13.8 13.3 06/17/2005 23:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 86 61 142 255 13.5 0 13.8 13.3 06/18/2005 00:00:00 1.5 0.2 1.9 0.7 1.4 0.2 1.9 0.7 0.8 0.3 1.5 0.4 104 5 101 255 13.3 0.1 13.8 13 06/18/2005 00:10:00 1.4 0.2 1.9 0.7 1.3 0.2 1.5 0.4 0.8 0.4 1.5 0.4 104 1 105 255 13.2 0 13.8 13 06/18/2005 00:20:00 1.3 0.2 1.9 0.7 1.2 0.2 1.5 0.7 0.8 0.3 1.5 0.4 99 7 105 255 13.1 0 13.3 13 06/18/2005 00:30:00 1.1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 87 0 87 255 13.1 0 13.3 12.7 06/18/2005 00:40:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.5 0.2 1.1 0.4 87 0 87 255 13 0 13.3 12.7 06/18/2005 00:50:00 1.4 0.6 3 0.4 1.3 0.7 3 0.4 0.8 0.5 1.9 0.4 47 26 19 255 12.9 0 13.3 12.7 06/18/2005 01:00:00 2.7 0.6 4.2 0.7 2.7 0.7 4.6 0.7 2.1 0.5 3.4 0.4 60 22 79 255 12.9 0.1 13.5 12.7 06/18/2005 01:10:00 3.1 0.6 4.6 1.9 3.1 0.6 4.6 1.5 2.3 0.6 4.2 1.1 73 8 76 255 13.4 0.1 13.8 13 06/18/2005 01:20:00 2.8 0.6 4.2 1.1 2.7 0.7 4.2 0.4 1.9 0.7 3.4 0.4 76 11 58 255 13.4 0 14.1 13.3 06/18/2005 01:30:00 2.5 0.7 4.2 0.7 2.4 0.7 4.2 1.1 1.8 0.7 3.4 0.4 92 12 84 255 13.6 0 14.1 13.5 06/18/2005 01:40:00 2.8 0.6 3.8 1.1 2.7 0.6 4.6 1.1 2 0.6 3.4 0.7 93 12 91 255 13.9 0 14.6 13.5 06/18/2005 01:50:00 2.8 0.5 3.8 1.1 2.8 0.5 3.8 1.5 2.1 0.5 3.4 0.7 103 9 82 255 14.3 0 14.9 14.1 06/18/2005 02:00:00 3.2 0.4 4.2 2.3 3.1 0.4 4.2 1.9 2.4 0.4 3.4 1.1 102 9 106 255 14.2 0 14.9 14.1 06/18/2005 02:10:00 3.2 0.6 4.6 1.5 3.2 0.7 4.9 1.1 2.4 0.6 4.2 1.1 79 20 74 255 14.4 0 14.9 14.4 06/18/2005 02:20:00 3.9 0.8 6.5 1.9 4 0.7 6.1 2.3 3.2 0.8 6.1 1.5 83 15 71 255 14.8 0.1 15.7 14.6 06/18/2005 02:30:00 4.7 0.9 7.2 2.3 4.6 0.9 7.2 2.3 3.8 0.9 6.5 1.5 96 12 102 255 15 0 15.7 15.2 06/18/2005 02:40:00 4.8 1.3 9.9 1.9 4.8 1.4 9.5 1.9 3.9 1.3 7.6 0.4 96 23 102 255 15.7 0.2 16.3 15.2 06/18/2005 02:50:00 5.2 1.2 8.8 2.6 5.3 1.2 9.5 2.6 4.2 1.2 7.6 0.7 77 19 66 255 16.2 0.1 16.8 16 06/18/2005 03:00:00 5.6 1.1 8.4 2.6 5.5 1.1 8.8 3 4.5 1.2 8 2.3 83 15 84 255 16.1 0 16.8 16 06/18/2005 03:10:00 5.6 1.1 8.4 3 5.7 1 8.4 2.6 4.5 1.1 7.6 1.5 95 14 90 255 15.7 0 16.3 15.5 06/18/2005 03:20:00 5.1 0.9 7.2 1.9 5.1 0.9 7.2 2.6 4.1 1 7.2 1.5 90 16 99 255 15.5 0 16 15.5 06/18/2005 03:30:00 4.9 1.2 8.8 2.3 4.9 1.2 8.4 1.9 4 1.2 6.5 1.5 85 19 100 255 15.7 0 16.3 15.5 06/18/2005 03:40:00 5.3 1.3 8.8 1.5 5.4 1.2 8.4 2.3 4.3 1.3 7.2 1.1 79 16 68 255 16.1 0.2 16.8 15.7 06/18/2005 03:50:00 4.5 1.2 8 1.9 4.5 1.3 8 1.5 3.7 1.2 6.8 0.7 66 16 72 255 16.8 0 17.1 16.6 06/18/2005 04:00:00 4.8 1 7.6 2.6 4.8 1 7.6 2.3 3.9 1 6.8 1.5 68 18 90 255 16.7 0.1 17.1 16.6 06/18/2005 04:10:00 4.4 1.1 7.2 1.5 4.4 1.1 7.2 1.9 3.7 1.2 6.1 0.4 78 17 83 255 16.6 0.2 16.8 16.3 06/18/2005 04:20:00 4.4 1.2 7.6 1.5 4.4 1.1 7.2 1.9 3.3 1.1 6.1 1.1 80 15 81 255 16.4 0.2 16.8 16.3 06/18/2005 04:30:00 4.7 0.9 6.8 2.6 4.6 1 6.8 2.3 3.6 0.9 5.7 1.1 81 15 81 255 16.2 0.2 16.8 16 06/18/2005 04:40:00 5.2 0.9 7.2 2.6 5.2 0.9 7.2 3 4.2 1.1 6.5 1.5 86 12 81 255 16.1 0 16.8 15.7 06/18/2005 04:50:00 5.2 1 8 2.6 5.1 0.9 7.2 2.6 4.1 1 6.8 1.5 81 15 55 255 15.9 0.1 16.6 15.7 06/18/2005 05:00:00 6.2 1.4 9.9 2.3 6.1 1.3 10.3 2.6 4.8 1.3 8.8 1.9 75 15 61 255 16.1 0.2 16.8 16 06/18/2005 05:10:00 6.5 1.3 9.5 3.4 6.5 1.2 9.5 3.4 5.3 1.3 8.8 2.3 75 17 99 255 16.6 0 16.8 16.6 06/18/2005 05:20:00 5.7 1.4 9.5 2.3 5.7 1.4 9.5 1.9 4.6 1.5 8.8 1.1 78 17 59 255 16.8 0 17.1 16.8 06/18/2005 05:30:00 6.6 1.3 9.5 2.6 6.6 1.3 9.9 2.3 5.3 1.3 8.8 1.5 86 16 89 255 16.6 0.1 17.1 16.3 06/18/2005 05:40:00 6.8 1.3 10.3 3.8 6.8 1.3 9.9 3.8 5.7 1.5 10.3 2.3 92 16 99 255 16.4 0 16.8 16.3 06/18/2005 05:50:00 6.3 1.5 10.3 3.4 6.3 1.5 10.7 3.4 5.1 1.6 9.5 1.5 80 16 61 255 16.4 0.1 16.8 16.3 06/18/2005 06:00:00 6.1 1.3 9.1 3.4 6 1.3 9.1 3.4 5 1.4 8 1.9 82 15 89 255 16.4 0.1 16.8 16.3 06/18/2005 06:10:00 7 2 12.6 3 7.1 2.1 12.6 3.4 5.8 1.9 11.1 1.5 85 19 62 255 16.5 0 17.1 16.6 06/18/2005 06:20:00 6.4 1.6 10.7 2.6 6.4 1.6 10.7 2.6 5.2 1.7 9.5 1.5 78 17 72 255 16.8 0 17.1 16.6 06/18/2005 06:30:00 7 1.5 13.7 3.8 6.9 1.5 13.3 3.8 5.8 1.4 11.1 2.6 75 20 115 255 17.1 0 17.4 16.8 06/18/2005 06:40:00 7.8 2 13.7 2.3 7.9 2 13 3 6.6 1.9 11.8 3 68 18 74 255 17.2 0 17.7 16.8 06/18/2005 06:50:00 8.8 2.1 13.7 3 8.8 2.1 14.1 3.4 7.5 2 13.3 2.3 61 15 37 255 17.6 0 18 17.4 06/18/2005 07:00:00 7.8 1.8 12.2 3.4 7.8 1.9 12.6 3.8 6.6 1.8 12.6 3 65 15 94 255 17.3 0.1 17.7 17.1 06/18/2005 07:10:00 7.1 1.8 13 3 7.1 1.8 12.6 3 6.1 1.6 11.5 2.6 62 18 51 255 17.3 0 17.7 17.1 06/18/2005 07:20:00 7.5 1.7 11.8 3.4 7.5 1.7 11.8 3 6.3 1.5 10.7 3 59 19 41 255 17.5 0 18 17.1 06/18/2005 07:30:00 7.5 1.7 11.8 3.4 7.5 1.8 11.8 3 6.1 1.8 10.7 2.3 63 20 52 255 18.2 0.1 18.8 17.7 06/18/2005 07:40:00 7 1.4 10.7 3.4 7 1.4 10.7 3 5.9 1.4 9.5 2.6 67 15 64 255 18.5 0.1 19.1 18.2 06/18/2005 07:50:00 6.4 1.7 10.3 2.3 6.4 1.7 10.3 1.9 5.4 1.7 11.1 1.1 66 19 58 255 18.3 0 18.8 18.2 06/18/2005 08:00:00 7.1 1.3 9.9 3.4 7.1 1.3 9.9 3.4 5.8 1.5 9.1 2.3 64 15 76 255 18.2 0 18.5 18 06/18/2005 08:10:00 7.7 1.9 12.2 3.4 7.8 2 12.6 3 6.5 1.8 11.8 2.6 64 16 62 255 18.2 0 18.5 18 06/18/2005 08:20:00 7.1 1.3 10.7 3.4 7.1 1.3 11.1 3 5.9 1.5 9.9 2.6 64 16 58 255 18.3 0 18.5 18.2 06/18/2005 08:30:00 7 1.2 10.3 3.8 7 1.3 10.3 3.8 5.9 1.4 10.7 3.4 64 17 34 255 18.3 0 18.8 18.2 06/18/2005 08:40:00 7.2 1.3 9.9 3.8 7.2 1.3 10.7 4.6 5.9 1.5 9.1 2.3 64 16 49 255 18.2 0 18.5 17.7 06/18/2005 08:50:00 6.9 1.5 11.5 3.8 6.9 1.6 11.8 3.8 5.7 1.5 9.5 2.3 66 17 58 255 17.7 0 18.2 17.4 06/18/2005 09:00:00 6.7 1.5 11.1 2.6 6.7 1.5 11.1 3 5.5 1.7 10.3 1.9 64 15 64 255 17.3 0.1 17.7 17.1 06/18/2005 09:10:00 8 1.7 11.8 4.6 8 1.7 12.2 3.8 6.6 1.8 11.5 3 60 15 63 255 17.3 0.1 17.7 17.1 06/18/2005 09:20:00 7.8 1.7 12.2 2.6 7.8 1.8 11.8 3 6.4 1.9 11.1 2.3 61 18 71 255 17.3 0 17.7 17.1 06/18/2005 09:30:00 8.1 1.7 13.3 3.8 8.2 1.7 13.3 3.8 6.8 2 11.1 2.6 63 17 62 255 17.5 0 17.7 17.1 06/18/2005 09:40:00 7.4 1.5 11.8 3.4 7.5 1.6 12.6 3.8 6.1 1.7 10.7 2.6 62 19 94 255 17.8 0 18 17.4 06/18/2005 09:50:00 7.5 1.7 11.5 3.4 7.6 1.7 11.8 3.4 6.4 1.8 11.8 2.3 69 17 55 255 17.6 0 18 17.4 06/18/2005 10:00:00 7.4 2.1 12.6 3.4 7.4 2.1 12.6 3.4 6.2 1.8 11.5 2.6 66 17 73 255 17.8 0 18 17.4 06/18/2005 10:10:00 6.5 1.6 11.1 2.6 6.5 1.7 10.7 2.6 5.5 1.7 9.9 1.9 69 15 73 255 18.1 0 18.2 17.7 06/18/2005 10:20:00 6.5 1.3 9.5 3.4 6.5 1.3 10.3 3.4 5.6 1.3 8.8 2.3 71 17 73 255 18.2 0 18.5 18 06/18/2005 10:30:00 6.7 1.5 10.7 3 6.6 1.6 11.1 3 5.6 1.5 9.5 1.9 69 17 73 255 18.3 0 18.8 18.2 06/18/2005 10:40:00 7 1.5 11.1 3.4 7 1.5 11.1 3.4 5.9 1.5 9.5 1.9 65 15 52 255 18.2 0 18.5 18 06/18/2005 10:50:00 7.5 2.1 12.6 3 7.5 2 12.6 3.4 6.4 2 11.1 1.9 53 17 66 255 18 0 18.2 17.7 06/18/2005 11:00:00 8.2 1.4 12.2 4.2 8 1.5 11.5 4.2 7.1 1.6 11.1 3.8 42 15 53 255 18 0 18.2 17.7 06/18/2005 11:10:00 8.1 1.3 11.1 4.2 8 1.5 12.2 4.2 6.7 1.5 11.1 2.3 38 14 19 255 17.7 0 18.2 17.4 06/18/2005 11:20:00 6.2 1.5 10.7 3 6.2 1.5 9.9 2.6 5.2 1.4 9.5 2.6 45 15 40 255 17.5 0 17.7 17.4 06/18/2005 11:30:00 6.6 1.5 9.9 3 6.5 1.5 10.3 3 5.4 1.5 9.1 2.3 39 12 45 255 17.3 0.1 17.7 17.1 06/18/2005 11:40:00 7.1 1.1 11.1 3.8 7 1.1 11.5 4.2 6 1.2 8.8 2.3 34 12 51 255 17.1 0 17.4 16.8 06/18/2005 11:50:00 7.2 1.6 13.3 3.8 7.1 1.6 13.7 3.4 5.9 1.5 11.5 2.6 21 13 23 255 17 0 17.4 16.8 06/18/2005 12:00:00 7.5 1.5 11.8 3.4 7.5 1.5 11.5 3 5.7 1.7 9.9 2.3 16 13 12 255 16.9 0.1 17.4 16.8 06/18/2005 12:10:00 2.7 0.7 4.6 1.1 2.4 0.8 4.6 0.7 1.9 0.9 4.2 0.4 326 28 294 255 16.7 0 17.1 16.6 06/18/2005 12:20:00 2.2 1.3 5.7 0.4 2.1 1.3 5.3 0.4 1.7 1.2 5.3 0.4 281 22 275 255 16.5 0 16.8 16.3 06/18/2005 12:30:00 1.9 0.7 4.2 0.4 1.7 0.8 4.2 0.4 1.3 0.8 3.4 0.4 294 24 279 255 16.6 0 16.8 16.6 06/18/2005 12:40:00 2.5 0.7 4.2 0.7 2.3 0.8 4.2 0.7 2 0.9 4.2 0.4 297 20 303 255 16.4 0 16.8 16.3 06/18/2005 12:50:00 2.5 1 4.6 0.4 2.3 1.1 4.9 0.4 2.1 1 5.3 0.4 283 22 303 255 16.1 0 16.6 16.3 06/18/2005 13:00:00 1.8 1 4.2 0.4 1.6 1 4.2 0.4 1.2 0.9 4.6 0.4 279 32 274 255 16.2 0 16.8 16.3 06/18/2005 13:10:00 2.6 1.3 6.1 0.4 2.5 1.4 6.1 0.4 1.9 1.3 5.3 0.4 287 38 258 255 16.3 0.1 16.8 15.7 06/18/2005 13:20:00 1.9 1 4.6 0.4 1.6 1 4.6 0.4 1.2 0.8 4.2 0.4 290 35 248 255 15.5 0 16 15.2 06/18/2005 13:30:00 2.7 0.9 4.9 0.7 2.5 0.9 4.6 0.4 1.8 0.9 4.9 0.4 233 17 223 255 15.5 0.2 16 15.2 06/18/2005 13:40:00 3.2 1.1 7.6 0.4 3.3 1.2 7.6 0.4 2.2 1.1 6.1 0.4 244 29 217 255 15.1 0.1 15.7 14.9 06/18/2005 13:50:00 3 1.1 6.5 0.4 3.1 1.1 5.7 0.4 2.3 1 5.3 0.4 280 27 260 255 14.8 0.1 15.5 14.6 06/18/2005 14:00:00 3.4 1.3 6.1 0.4 3.3 1.3 6.1 0.4 2.3 1.4 5.7 0.4 267 23 269 255 14.5 0 15.2 14.4 06/18/2005 14:10:00 2.8 1.1 5.7 0.4 2.9 1.1 6.1 0.4 2.1 1.2 5.7 0.4 257 24 235 255 14.3 0.1 14.9 14.4 06/18/2005 14:20:00 2.8 0.8 4.9 1.1 2.7 0.8 4.9 0.7 1.9 1 4.2 0.4 252 19 253 255 14.2 0.1 14.6 14.1 06/18/2005 14:30:00 2.7 1 4.9 0.7 2.6 1 4.9 0.4 1.6 1 4.6 0.4 261 24 289 255 14.2 0.2 14.6 14.1 06/18/2005 14:40:00 2.7 1 5.3 0.7 2.7 1.1 5.3 0.4 1.6 1 4.2 0.4 240 18 253 255 14.2 0.2 14.6 14.1 06/18/2005 14:50:00 2.2 0.9 4.6 0.4 2.1 1 4.6 0.4 1.3 0.8 3.8 0.4 241 24 244 255 14.4 0.1 14.9 14.4 06/18/2005 15:00:00 2.3 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.6 0.8 3.4 0.4 247 18 266 255 14.4 0.1 14.9 14.4 06/18/2005 15:10:00 2 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.4 0.6 3 0.4 235 20 253 255 14.2 0.2 14.9 14.1 06/18/2005 15:20:00 1.4 0.7 2.6 0.4 1.2 0.7 2.6 0.4 0.9 0.5 2.3 0.4 210 16 212 255 14.2 0.1 14.6 14.1 06/18/2005 15:30:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 223 18 225 255 14.2 0 14.9 14.4 06/18/2005 15:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 252 2 250 255 14.2 0 14.6 14.1 06/18/2005 15:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 319 14 302 255 14.4 0 14.9 14.4 06/18/2005 16:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 260 64 303 255 14.3 0 14.9 14.4 06/18/2005 16:10:00 0.8 0.5 1.9 0.4 0.6 0.5 1.9 0.4 0.5 0.3 1.9 0.4 260 20 219 255 14.2 0 14.9 14.1 06/18/2005 16:20:00 1 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 246 24 251 255 14.2 0.1 14.6 13.8 06/18/2005 16:30:00 1.9 0.9 3.8 0.4 1.8 1 4.2 0.4 1.1 0.8 3 0.4 232 24 244 255 14 0.1 14.6 13.8 06/18/2005 16:40:00 1.4 0.7 3.4 0.4 1.3 0.8 3 0.4 1 0.6 3 0.4 236 24 234 255 13.9 0 14.6 13.8 06/18/2005 16:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 236 16 225 255 14 0.1 14.6 13.8 06/18/2005 17:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 259 17 238 255 14.2 0.1 14.6 13.8 06/18/2005 17:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 272 7 255 255 14.3 0.1 14.6 14.4 06/18/2005 17:20:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 256 8 258 255 14.3 0 14.9 14.4 06/18/2005 17:30:00 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 265 10 241 255 14.3 0 14.9 14.1 06/18/2005 17:40:00 1.1 0.5 2.6 0.4 0.8 0.6 2.3 0.4 0.5 0.3 1.9 0.4 248 19 212 255 14.6 0 15.2 14.6 06/18/2005 17:50:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.5 1.9 0.4 264 36 218 255 14.5 0 14.9 14.4 06/18/2005 18:00:00 1.1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 279 17 259 255 14.4 0 14.9 14.4 06/18/2005 18:10:00 1.1 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 264 17 251 255 14.2 0.1 14.6 14.1 06/18/2005 18:20:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.1 1.5 0.4 258 17 259 255 14.2 0.1 14.6 14.1 06/18/2005 18:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 258 14 269 255 14.1 0.1 14.6 13.8 06/18/2005 18:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 245 47 149 255 14.2 0 14.4 14.1 06/18/2005 18:50:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 220 27 219 255 14.2 0 14.9 14.1 06/18/2005 19:00:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 242 12 240 255 14.3 0 14.9 14.4 06/18/2005 19:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 224 0 225 255 14.4 0 14.6 14.4 06/18/2005 19:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 309 61 1 255 14.4 0 14.6 14.4 06/18/2005 19:30:00 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 336 0 337 255 14.2 0 14.6 14.1 06/18/2005 19:40:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 17 11 255 14.1 0 14.6 14.1 06/18/2005 19:50:00 1.2 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 40 14 61 255 14.2 0 14.4 14.1 06/18/2005 20:00:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.9 0.4 47 13 60 255 14.2 0 14.6 14.1 06/18/2005 20:10:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 49 11 50 255 14.2 0 14.6 14.1 06/18/2005 20:20:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 36 15 24 255 14.1 0 14.4 14.1 06/18/2005 20:30:00 1.7 0.4 2.3 0.4 1.5 0.5 2.3 0.4 0.8 0.4 1.9 0.4 16 5 18 255 14.1 0 14.4 13.8 06/18/2005 20:40:00 1.1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 347 20 12 255 14 0 14.4 13.8 06/18/2005 20:50:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 317 18 318 255 14 0.1 14.6 13.8 06/18/2005 21:00:00 1.2 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 310 18 283 255 13.9 0 14.6 13.8 06/18/2005 21:10:00 1.2 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.1 0.4 318 17 307 255 13.8 0 14.4 13.5 06/18/2005 21:20:00 1 0.7 3 0.4 0.8 0.7 3 0.4 0.6 0.5 2.3 0.4 307 7 298 255 13.8 0 14.4 13.5 06/18/2005 21:30:00 1.6 0.6 2.6 0.4 1.2 0.6 2.3 0.4 0.8 0.5 1.9 0.4 354 30 300 255 13.7 0 14.1 13.5 06/18/2005 21:40:00 1.4 0.7 2.6 0.4 1.1 0.6 2.3 0.4 0.6 0.3 1.5 0.4 2 28 4 255 13.7 0 14.1 13.5 06/18/2005 21:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 40 15 48 255 13.7 0.1 14.1 13.5 06/18/2005 22:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 48 4 51 255 13.6 0.1 14.1 13.5 06/18/2005 22:10:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.1 0.4 57 8 58 255 13.5 0.1 13.8 13.5 06/18/2005 22:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 77 7 56 255 13.5 0.1 13.8 13.3 06/18/2005 22:30:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 0.7 0.4 85 9 92 255 13.5 0 13.8 13.3 06/18/2005 22:40:00 0.7 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 61 7 55 255 13.4 0 13.8 13.3 06/18/2005 22:50:00 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 0.9 0.5 2.3 0.4 54 13 45 255 13.4 0 13.8 13.3 06/18/2005 23:00:00 1.7 0.3 2.6 0.7 1.4 0.4 2.3 0.4 0.8 0.4 1.9 0.4 35 15 42 255 13.5 0 13.8 13.3 06/18/2005 23:10:00 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 23 20 1 255 13.3 0 13.5 13.3 06/18/2005 23:20:00 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 15 12 17 255 13.3 0 13.5 13.3 06/18/2005 23:30:00 1.1 0.7 3 0.4 0.8 0.6 3 0.4 0.6 0.4 2.3 0.4 346 56 348 255 13.3 0 13.3 13 06/18/2005 23:40:00 1.2 0.3 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 56 11 29 255 13.2 0 13.3 13 06/18/2005 23:50:00 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 65 15 45 255 13.1 0 13.3 13 06/19/2005 00:00:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 42 11 46 255 13.1 0 13.3 13 06/19/2005 00:10:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 12 66 23 255 13 0 13 13 06/19/2005 00:20:00 1 0.7 3 0.4 0.7 0.7 3 0.4 0.5 0.4 2.3 0.4 308 45 309 255 12.9 0 13 12.7 06/19/2005 00:30:00 1.9 1.2 5.3 0.4 1.5 1.3 4.9 0.4 1 1.1 4.9 0.4 239 32 193 255 12.8 0 13 12.7 06/19/2005 00:40:00 3 0.8 5.7 1.5 2.9 0.8 6.1 1.1 2 0.8 4.9 0.4 197 16 219 255 12.5 0.1 12.7 12.2 06/19/2005 00:50:00 2.6 0.7 4.9 0.7 2.5 0.8 4.6 0.4 1.5 0.8 3.4 0.4 194 18 204 255 12.1 0.1 12.5 11.9 06/19/2005 01:00:00 2.3 0.8 5.3 0.4 2.2 1 4.9 0.4 1.3 0.9 4.9 0.4 190 16 192 255 11.7 0 12.2 11.7 06/19/2005 01:10:00 2 0.6 3.8 0.7 2 0.6 3.8 0.4 1.3 0.7 3 0.4 182 14 188 255 11.6 0 11.7 11.7 06/19/2005 01:20:00 1.8 0.6 3.8 0.4 1.6 0.8 3.4 0.4 0.9 0.7 3 0.4 192 19 191 255 11.5 0 11.9 11.4 06/19/2005 01:30:00 1.9 0.6 3.4 0.4 1.7 0.8 3.8 0.4 0.7 0.5 2.6 0.4 196 22 198 255 11.3 0 11.4 11.1 06/19/2005 01:40:00 2.1 0.5 3.8 0.7 1.9 0.6 3.4 0.4 0.7 0.5 2.3 0.4 195 10 201 255 11.3 0 11.7 11.1 06/19/2005 01:50:00 2.1 0.6 4.9 1.1 2.3 0.6 4.2 1.1 1.3 0.7 3.8 0.4 179 9 192 255 11.1 0 11.4 11.1 06/19/2005 02:00:00 2.1 0.6 3.8 0.4 2.1 0.7 3.4 0.4 1.1 0.6 3 0.4 186 11 193 255 11.1 0 11.1 11.1 06/19/2005 02:10:00 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.5 0.2 1.5 0.4 213 17 189 255 11 0 11.1 10.9 06/19/2005 02:20:00 2.2 0.7 3.8 0.4 2 0.8 4.2 0.4 0.8 0.5 2.6 0.4 218 12 226 255 10.8 0 11.1 10.6 06/19/2005 02:30:00 2.6 0.6 4.6 1.1 2.4 0.7 4.2 0.4 0.8 0.6 3 0.4 224 14 227 255 10.7 0 10.9 10.6 06/19/2005 02:40:00 2.6 0.7 4.2 1.1 2.4 0.8 4.2 0.4 1.1 0.6 3.4 0.4 224 13 222 255 10.6 0 10.9 10.6 06/19/2005 02:50:00 2.9 0.8 5.3 1.1 2.7 0.8 4.9 1.1 1.6 0.8 3.8 0.4 224 17 207 255 10.7 0 10.9 10.6 06/19/2005 03:00:00 2.4 0.7 4.9 1.1 2.2 0.7 4.6 0.4 1.1 0.7 4.2 0.4 230 14 235 255 10.5 0 10.6 10.3 06/19/2005 03:10:00 3 0.9 5.3 0.4 2.7 1 5.3 0.4 1.6 0.8 3.8 0.4 229 16 201 255 10.3 0 10.6 10.3 06/19/2005 03:20:00 2.9 0.7 4.6 1.1 2.7 0.7 4.6 0.7 1.5 0.7 3.8 0.4 230 12 235 255 10.3 0 10.3 10.3 06/19/2005 03:30:00 2.5 0.8 4.9 0.7 2.4 0.8 5.3 0.7 1.1 0.8 4.6 0.4 231 15 232 255 10.1 0 10.3 10.1 06/19/2005 03:40:00 2.6 0.7 4.2 1.1 2.4 0.8 4.2 0.4 1.1 0.7 3.4 0.4 235 13 241 255 10 0 10.1 9.8 06/19/2005 03:50:00 2.3 0.5 3.8 1.1 2.1 0.5 3.4 0.7 0.7 0.4 1.9 0.4 225 13 255 255 9.7 0 9.8 9.6 06/19/2005 04:00:00 2.6 0.5 3.8 0.7 2.4 0.5 3.8 1.5 1.1 0.5 2.6 0.4 213 12 212 255 9.5 0 9.6 9.6 06/19/2005 04:10:00 2.5 0.6 4.2 1.1 2.3 0.6 3.8 0.4 0.9 0.5 3 0.4 223 11 233 255 9.5 0 9.6 9.6 06/19/2005 04:20:00 2.3 0.5 3.4 1.1 2 0.5 3.4 0.7 0.7 0.4 1.9 0.4 227 12 225 255 9.5 0 9.6 9.3 06/19/2005 04:30:00 2.5 0.5 4.2 1.1 2.3 0.5 3.8 0.7 1 0.6 3 0.4 212 11 206 255 9.4 0 9.6 9.3 06/19/2005 04:40:00 3 0.7 4.9 1.5 2.8 0.7 4.9 1.1 1.5 0.8 4.2 0.4 217 14 227 255 9.5 0 9.6 9.3 06/19/2005 04:50:00 3.3 0.8 5.7 1.5 3.2 0.8 5.7 1.5 1.8 1 4.6 0.4 216 16 203 255 9.8 0 10.1 9.6 06/19/2005 05:00:00 3.2 1 6.5 1.1 3.1 1.1 6.5 0.4 1.7 1.1 4.6 0.4 216 16 211 255 10.1 0 10.3 10.1 06/19/2005 05:10:00 2.8 0.8 5.3 1.1 2.6 0.8 5.3 1.1 1.6 0.9 4.9 0.4 214 15 219 255 10.4 0 10.6 10.3 06/19/2005 05:20:00 2.8 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.4 0.6 3 0.4 202 13 204 255 10.6 0 10.6 10.6 06/19/2005 05:30:00 2.4 0.6 3.8 1.1 2.2 0.6 3.8 0.4 1.3 0.7 3 0.4 204 11 211 255 10.6 0 10.6 10.6 06/19/2005 05:40:00 2.5 0.6 4.2 1.1 2.3 0.6 4.2 0.7 1.5 0.8 4.2 0.4 200 15 213 255 10.6 0 10.6 10.6 06/19/2005 05:50:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.1 0.7 3.4 0.4 194 14 208 255 10.6 0 10.6 10.6 06/19/2005 06:00:00 2 0.5 3.4 1.1 2.1 0.6 3.8 0.4 0.8 0.6 3.8 0.4 180 15 188 255 10.5 0 10.6 10.6 06/19/2005 06:10:00 1.7 0.6 3 0.4 1.5 0.7 3.4 0.4 0.7 0.5 3 0.4 185 23 171 255 10.7 0.1 11.1 10.6 06/19/2005 06:20:00 1.6 0.6 3.4 0.4 1.4 0.7 3 0.4 0.6 0.5 3.4 0.4 190 17 195 255 11.1 0 11.4 11.1 06/19/2005 06:30:00 1.6 0.6 3.8 0.4 1.3 0.6 3.8 0.4 0.7 0.5 2.3 0.4 193 14 204 255 11.5 0 11.7 11.4 06/19/2005 06:40:00 1.9 0.7 4.2 0.7 1.7 0.9 3.8 0.4 1.3 0.8 3.8 0.4 195 15 190 255 11.5 0 11.7 11.4 06/19/2005 06:50:00 1.9 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.1 0.8 3.4 0.4 185 21 211 255 11.3 0 11.4 11.4 06/19/2005 07:00:00 1.7 0.6 3 0.4 1.6 0.7 3.4 0.4 1 0.5 2.6 0.4 189 19 190 255 11.4 0 11.7 11.4 06/19/2005 07:10:00 1.2 0.5 3 0.4 0.9 0.6 2.6 0.4 0.7 0.4 2.3 0.4 184 19 198 255 11.7 0 11.9 11.7 06/19/2005 07:20:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.2 0.7 2.6 0.4 187 19 206 255 11.7 0 11.7 11.7 06/19/2005 07:30:00 1.6 0.7 3.4 0.4 1.3 0.8 3.4 0.4 1.1 0.7 3.4 0.4 190 20 180 255 11.8 0 11.9 11.7 06/19/2005 07:40:00 1.9 0.6 3.4 0.7 1.8 0.6 3 0.4 1.5 0.7 3.4 0.4 193 19 203 255 12 0 12.5 11.9 06/19/2005 07:50:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.1 0.7 3 0.4 191 20 191 255 12.1 0 12.7 11.9 06/19/2005 08:00:00 1.5 0.8 3.4 0.4 1.3 0.8 3 0.4 0.9 0.8 3 0.4 189 15 192 255 12.1 0 12.5 11.9 06/19/2005 08:10:00 1.3 0.6 3 0.4 1 0.6 3 0.4 0.6 0.4 2.3 0.4 198 18 154 255 12.2 0 12.5 11.9 06/19/2005 08:20:00 1.8 0.6 3.8 0.4 1.5 0.7 3.4 0.4 1.2 0.7 2.6 0.4 182 21 182 255 12.7 0.1 13 12.5 06/19/2005 08:30:00 2 0.8 4.9 0.4 1.9 0.8 4.2 0.4 1.6 0.8 4.2 0.4 169 19 147 255 12.8 0 13.3 12.7 06/19/2005 08:40:00 1.5 0.7 3.8 0.4 1.3 0.8 3.4 0.4 1 0.7 3 0.4 182 27 152 255 13.1 0 13.3 12.7 06/19/2005 08:50:00 0.9 0.7 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 196 11 199 255 12.9 0 13.3 12.7 06/19/2005 09:00:00 1.6 0.8 3.4 0.4 1.5 0.8 3 0.4 1.1 0.8 3.4 0.4 200 26 212 255 12.9 0 13.3 12.7 06/19/2005 09:10:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 0.9 0.6 3 0.4 250 30 252 255 12.8 0 13 12.7 06/19/2005 09:20:00 2.4 0.9 4.2 0.7 2.3 0.9 4.2 0.4 1.6 0.9 3.4 0.4 214 30 231 255 13.1 0 13.5 13 06/19/2005 09:30:00 1.9 0.9 4.6 0.4 1.8 1 4.2 0.4 1.3 1 3.8 0.4 229 39 211 255 13.3 0 13.8 13 06/19/2005 09:40:00 2.4 0.7 4.2 0.4 2.3 0.8 4.2 0.4 1.7 0.8 3.8 0.4 220 22 225 255 13 0.1 13.5 12.7 06/19/2005 09:50:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 250 21 260 255 13.1 0.1 13.5 12.7 06/19/2005 10:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 156 66 189 255 13.3 0 13.5 13 06/19/2005 10:10:00 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.6 0.5 2.6 0.4 250 35 253 255 13.3 0.2 13.8 12.7 06/19/2005 10:20:00 2 0.8 3.8 0.4 1.8 0.9 3.8 0.4 1.1 0.6 3 0.4 246 21 257 255 13.1 0 13.5 13 06/19/2005 10:30:00 1.5 0.7 3.4 0.4 1.3 0.8 3.4 0.4 1 0.7 3 0.4 267 23 270 255 13.3 0 13.5 13 06/19/2005 10:40:00 1.9 1.1 3.8 0.4 1.8 1.2 3.8 0.4 1.3 0.9 3.4 0.4 217 18 206 255 13.4 0 13.8 13.3 06/19/2005 10:50:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.4 1.6 0.8 3.4 0.4 211 15 200 255 13.5 0.1 13.8 13.3 06/19/2005 11:00:00 2.4 0.9 5.3 0.4 2.3 1 4.9 0.4 1.8 0.8 3.4 0.4 246 27 229 255 13.7 0.1 14.4 13.5 06/19/2005 11:10:00 1.5 0.8 3.4 0.4 1.3 0.8 3 0.4 1.1 0.7 3.4 0.4 260 36 231 255 13.7 0 13.8 13.5 06/19/2005 11:20:00 1.8 0.7 3.4 0.4 1.7 0.8 3.8 0.4 1.2 0.7 3 0.4 252 21 235 255 13.8 0 14.1 13.5 06/19/2005 11:30:00 1.8 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.2 0.7 3.4 0.4 279 32 274 255 13.7 0 14.1 13.3 06/19/2005 11:40:00 2.5 0.6 4.2 1.1 2.3 0.7 3.8 0.4 1.8 0.8 3.4 0.4 236 18 235 255 13.8 0 14.1 13.5 06/19/2005 11:50:00 1.2 0.8 3.4 0.4 1.1 0.8 3.4 0.4 0.9 0.7 3 0.4 266 35 211 255 13.8 0 14.1 13.5 06/19/2005 12:00:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 257 27 247 255 13.7 0 14.1 13.3 06/19/2005 12:10:00 2.2 0.6 3.8 0.4 2 0.8 3.4 0.4 1.6 0.8 3.4 0.4 285 15 292 255 13.3 0.2 13.5 12.7 06/19/2005 12:20:00 1.6 0.4 3 0.7 1.4 0.5 2.6 0.4 0.8 0.4 1.9 0.4 299 16 288 255 12.8 0 13.3 12.7 06/19/2005 12:30:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.8 0.6 2.3 0.4 291 22 271 255 12.9 0.1 13.3 12.7 06/19/2005 12:40:00 1.3 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 324 22 316 255 13.5 0.1 13.8 13 06/19/2005 12:50:00 2 0.7 3.8 0.4 1.6 0.6 3.4 0.4 1 0.8 3.8 0.4 331 19 328 255 13.9 0 14.4 13.5 06/19/2005 13:00:00 2.7 0.4 3.8 1.9 2.5 0.5 3.4 1.1 1.6 0.8 3.4 0.4 355 12 355 255 14 0.1 14.6 13.8 06/19/2005 13:10:00 2.1 0.7 3.8 0.4 1.7 0.6 3.4 0.4 1.3 0.8 3.4 0.4 345 19 335 255 14.2 0.1 14.6 13.8 06/19/2005 13:20:00 1.4 0.6 3 0.4 1.1 0.7 3 0.4 0.9 0.6 3 0.4 358 24 28 255 14.2 0 14.9 13.8 06/19/2005 13:30:00 2.7 0.7 4.9 1.1 2.5 0.8 4.6 0.7 1.6 1 4.2 0.4 11 16 15 255 14.7 0 15.5 14.6 06/19/2005 13:40:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 1.1 1.9 0.9 4.2 0.4 16 18 30 255 14.2 0.2 14.9 13.8 06/19/2005 13:50:00 2.8 0.5 3.8 1.1 2.6 0.5 3.8 1.1 1.8 0.8 3.8 0.4 359 20 10 255 14.3 0 14.9 13.8 06/19/2005 14:00:00 3.2 1 4.9 0.4 3.1 1.1 4.9 0.4 2.1 1 4.2 0.4 7 17 7 255 14.8 0 15.2 14.6 06/19/2005 14:10:00 3.4 0.8 4.6 1.1 3.1 0.9 4.9 0.4 2.2 1.1 4.6 0.4 352 14 353 255 14.6 0.1 15.2 14.4 06/19/2005 14:20:00 3.4 0.8 5.7 1.9 3.2 0.8 5.3 1.5 2.3 1.1 5.3 0.4 352 15 10 255 13.8 0.2 14.6 13.3 06/19/2005 14:30:00 3.2 1 4.9 0.4 3.1 1.1 4.9 0.4 2.3 1.1 4.2 0.4 14 17 7 255 13.6 0 14.1 13.3 06/19/2005 14:40:00 1.7 0.6 3.4 0.4 1.4 0.7 3 0.4 0.8 0.6 2.6 0.4 334 45 283 255 13.5 0.1 14.1 13.3 06/19/2005 14:50:00 1.6 0.5 3.4 0.4 1.3 0.6 3 0.4 0.7 0.5 2.3 0.4 14 18 5 255 13.6 0 14.1 13.3 06/19/2005 15:00:00 1 0.6 2.6 0.4 0.7 0.6 2.3 0.4 0.5 0.4 2.3 0.4 51 33 17 255 13.8 0 14.1 13.5 06/19/2005 15:10:00 2.1 0.8 3.8 0.4 1.9 0.9 3.8 0.4 1.6 0.8 3 0.4 27 11 6 255 14.3 0 14.6 13.8 06/19/2005 15:20:00 3.3 1 5.3 0.4 3.2 1 5.3 0.4 2.5 0.9 4.9 0.4 22 21 12 255 14.8 0.2 15.5 14.6 06/19/2005 15:30:00 2.8 1 5.3 0.4 2.7 1 5.3 0.4 2 1 4.2 0.4 22 30 10 255 15.5 0.1 16.3 15.2 06/19/2005 15:40:00 3.8 0.7 5.3 1.9 3.6 0.8 5.3 1.5 2.9 1 5.3 0.4 21 17 12 255 15.2 0.1 15.7 14.9 06/19/2005 15:50:00 2.4 1 4.2 0.4 2.2 1 4.2 0.4 1.6 0.8 4.2 0.4 9 29 353 255 15.6 0.1 16.3 15.5 06/19/2005 16:00:00 3.2 0.6 4.6 1.1 3 0.7 4.6 0.4 2 0.9 4.2 0.4 7 11 20 255 14.9 0.2 15.5 14.6 06/19/2005 16:10:00 3.2 0.6 4.9 1.1 3 0.7 4.6 0.4 2.2 0.8 4.2 0.4 5 20 19 255 14.5 0 14.6 14.4 06/19/2005 16:20:00 4.4 0.7 6.1 2.3 4.4 0.7 6.1 2.3 3.5 1.1 6.1 0.4 16 13 20 255 14.6 0 14.9 14.6 06/19/2005 16:30:00 5.2 0.8 7.2 2.6 5.1 0.8 7.2 3 3.8 1.1 6.5 1.1 12 12 14 255 14.4 0.1 14.9 14.1 06/19/2005 16:40:00 5.4 1 7.6 3 5.4 1 7.6 3 4 1.5 7.2 1.1 14 11 2 255 13.8 0 14.4 13.5 06/19/2005 16:50:00 4.3 0.7 6.1 2.6 4.2 0.7 6.1 2.3 2.9 1 5.3 0.4 9 19 33 255 13.7 0 14.1 13.5 06/19/2005 17:00:00 4 1.4 6.8 1.1 3.9 1.4 6.8 0.4 2.9 1.5 7.2 0.4 14 19 20 255 13.7 0 14.1 13.3 06/19/2005 17:10:00 4.6 0.9 6.8 2.3 4.6 0.9 6.8 1.9 3.5 1.3 6.8 0.4 19 13 16 255 13.3 0 13.8 13 06/19/2005 17:20:00 5.4 1.1 8 2.6 5.3 1.2 8 2.6 4.3 1.4 7.6 1.1 21 13 43 255 13.3 0.1 13.8 12.7 06/19/2005 17:30:00 4.8 1.1 8 2.3 4.8 1.1 8 2.3 3.8 1.3 7.6 1.1 17 14 21 255 13.2 0 13.5 12.7 06/19/2005 17:40:00 5.6 1.1 9.1 2.6 5.5 1.1 9.5 2.6 4 1.4 8 1.1 20 16 34 255 13.3 0 13.8 13 06/19/2005 17:50:00 5.7 1.2 9.1 3 5.7 1.2 9.5 3 4.7 1.5 8.4 0.7 29 13 30 255 12.9 0.1 13.5 12.7 06/19/2005 18:00:00 5.7 1.2 8.8 3 5.7 1.2 8.4 3 4.6 1.3 7.6 1.5 21 11 17 255 12.5 0.1 13 12.2 06/19/2005 18:10:00 5.4 1.1 8 2.3 5.4 1.1 8 2.3 4.3 1.3 7.6 1.1 21 15 34 255 12.1 0 12.5 11.9 06/19/2005 18:20:00 4.5 1.2 7.6 1.5 4.4 1.2 7.6 1.5 3.3 1.3 6.8 0.4 19 15 20 255 12 0 12.5 11.9 06/19/2005 18:30:00 4.1 0.7 5.3 2.3 4 0.7 5.3 1.9 2.8 1.1 5.3 0.4 15 12 9 255 11.9 0.2 12.5 11.7 06/19/2005 18:40:00 4 0.6 5.7 2.6 3.9 0.6 5.3 2.3 3 1.1 5.3 0.4 18 10 19 255 12 0 12.5 11.9 06/19/2005 18:50:00 3.7 1 5.7 1.5 3.6 1 5.7 1.1 2.8 1.2 5.3 0.4 28 15 0 255 12.3 0 12.7 12.2 06/19/2005 19:00:00 3.3 0.6 4.6 1.5 3.2 0.6 4.6 1.5 2.4 0.7 4.2 0.4 16 13 3 255 12.3 0 12.7 12.2 06/19/2005 19:10:00 4.1 0.8 6.5 2.3 4 0.9 6.5 2.3 2.9 1.1 6.8 0.7 17 11 14 255 12.1 0 12.2 11.9 06/19/2005 19:20:00 4.2 0.9 7.2 1.5 4.1 1 7.6 1.5 3.1 1.1 5.7 0.4 15 12 28 255 11.9 0.1 12.2 11.7 06/19/2005 19:30:00 3.6 0.7 5.7 2.3 3.5 0.7 5.7 1.5 2.9 0.9 5.3 0.7 33 15 40 255 11.7 0 12.2 11.7 06/19/2005 19:40:00 3.3 0.7 5.3 1.5 3.2 0.8 5.3 1.5 2.7 0.9 4.6 1.1 35 13 20 255 11.5 0 11.9 11.4 06/19/2005 19:50:00 2.6 1 5.3 0.4 2.4 1.1 5.3 0.4 2 1.1 4.9 0.4 44 22 35 255 11.3 0.1 11.9 11.4 06/19/2005 20:00:00 2.3 0.6 3.8 0.4 2.2 0.7 3.8 0.4 1.5 0.8 3.4 0.4 54 17 47 255 11.3 0 11.7 11.1 06/19/2005 20:10:00 2.1 0.5 3.4 0.7 1.9 0.7 3.4 0.4 1.4 0.7 3.4 0.4 55 18 54 255 11.1 0 11.7 11.1 06/19/2005 20:20:00 2.5 0.8 4.6 0.4 2.3 0.9 4.2 0.4 1.8 0.9 3.8 0.4 57 15 56 255 11 0 11.4 10.9 06/19/2005 20:30:00 1.9 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 66 22 56 255 10.9 0 11.4 10.9 06/19/2005 20:40:00 1.5 0.6 2.6 0.4 1.2 0.7 2.6 0.4 0.8 0.4 1.9 0.4 67 23 56 255 10.9 0 11.4 10.9 06/19/2005 20:50:00 1.2 0.5 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 104 26 80 255 10.8 0.1 11.4 10.6 06/19/2005 21:00:00 1.3 0.7 3 0.4 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 135 15 147 255 10.7 0 11.1 10.6 06/19/2005 21:10:00 1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 144 28 103 255 10.6 0 11.1 10.6 06/19/2005 21:20:00 1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 51 20 77 255 10.5 0 10.9 10.6 06/19/2005 21:30:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 132 33 161 255 10.3 0 10.9 10.3 06/19/2005 21:40:00 1.4 0.4 2.3 0.4 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 135 11 142 255 10.3 0 10.6 10.3 06/19/2005 21:50:00 2 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1.2 0.6 2.3 0.4 91 7 91 255 10.4 0 10.6 10.3 06/19/2005 22:00:00 1.5 0.6 3 0.4 1.2 0.8 3 0.4 1 0.6 2.6 0.4 92 18 101 255 10.3 0 10.6 10.3 06/19/2005 22:10:00 2.5 0.7 4.2 1.5 2.3 0.7 3.8 0.7 1.7 0.7 3.4 0.4 66 9 68 255 10.3 0 10.3 10.3 06/19/2005 22:20:00 1.6 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.9 0.5 2.3 0.4 62 23 90 255 10.2 0 10.3 10.3 06/19/2005 22:30:00 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.8 0.5 2.3 0.4 62 12 43 255 10.2 0 10.3 10.3 06/19/2005 22:40:00 1.8 0.6 3 0.4 1.5 0.7 3 0.4 1 0.6 2.6 0.4 32 14 28 255 10.2 0 10.3 10.1 06/19/2005 22:50:00 1.3 0.7 3 0.4 1.1 0.8 3 0.4 0.6 0.5 2.6 0.4 20 28 25 255 10 0 10.3 9.8 06/19/2005 23:00:00 2.3 0.7 3.8 0.4 2.1 0.7 3.4 0.4 1.6 0.7 3 0.4 34 21 46 255 10 0 10.1 9.8 06/19/2005 23:10:00 1.7 0.5 3 0.7 1.4 0.6 2.6 0.4 1 0.6 2.6 0.4 40 12 43 255 9.8 0 10.1 9.8 06/19/2005 23:20:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 55 5 55 255 9.9 0 9.8 9.8 06/19/2005 23:30:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 9 40 255 9.8 0 9.8 9.6 06/19/2005 23:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 1 60 255 9.6 0 9.8 9.6 06/19/2005 23:50:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 62 4 59 255 9.5 0 9.6 9.3 06/20/2005 00:00:00 0.8 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.1 1.1 0.4 75 17 93 255 9.5 0 9.8 9.3 06/20/2005 00:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 87 0 87 255 9.5 0 9.6 9.6 06/20/2005 00:20:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.5 0.4 1.9 0.4 89 11 91 255 9.5 0 9.6 9.3 06/20/2005 00:30:00 1.7 0.7 3 0.4 1.4 0.7 3 0.4 0.7 0.6 2.6 0.4 103 12 106 255 9.5 0 9.6 9.3 06/20/2005 00:40:00 2 1 4.2 0.4 1.8 1 4.2 0.4 1.6 1.1 3.8 0.4 96 53 110 255 9.7 0 9.8 9.6 06/20/2005 00:50:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 274 41 156 255 9.7 0 9.8 9.6 06/20/2005 01:00:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 179 23 243 255 9.5 0 9.6 9.3 06/20/2005 01:10:00 2 0.8 4.2 0.4 1.7 1 4.2 0.4 1.1 0.6 3 0.4 219 19 220 255 9.5 0 9.6 9.3 06/20/2005 01:20:00 2 0.9 4.6 0.4 1.8 0.9 4.2 0.4 1.3 0.8 4.2 0.4 210 22 250 255 9.8 0 10.1 9.6 06/20/2005 01:30:00 1.6 0.6 3.4 0.4 1.3 0.7 3.4 0.4 0.7 0.4 1.9 0.4 217 19 216 255 10 0 10.1 9.8 06/20/2005 01:40:00 2.3 0.7 4.2 0.7 2.1 0.8 5.3 0.4 1.3 0.8 4.2 0.4 226 19 250 255 9.9 0 10.1 9.8 06/20/2005 01:50:00 3.7 1.1 6.8 1.5 3.6 1.2 7.2 1.1 2.6 1.2 5.7 0.4 229 17 215 255 10.1 0 10.3 9.8 06/20/2005 02:00:00 3.7 1.1 6.8 1.5 3.6 1.1 6.8 1.1 2.5 1.1 5.3 0.4 228 22 209 255 10.3 0 10.6 10.3 06/20/2005 02:10:00 3.7 0.9 5.7 1.5 3.6 1 5.7 0.4 2.4 1 5.7 0.4 233 22 244 255 10.3 0 10.6 10.3 06/20/2005 02:20:00 3.6 1.1 7.2 1.1 3.4 1.2 6.8 0.7 2.3 1.2 5.3 0.4 242 22 243 255 10.3 0 10.6 10.3 06/20/2005 02:30:00 4 1 6.5 1.5 3.9 1 6.5 1.5 2.6 1.2 6.5 0.4 240 20 216 255 10.2 0 10.3 10.3 06/20/2005 02:40:00 3.1 1.3 7.2 0.4 2.9 1.3 7.2 0.4 2.1 1.3 6.8 0.4 225 21 250 255 10.2 0 10.3 10.3 06/20/2005 02:50:00 2.3 0.8 5.3 0.4 2.1 0.9 4.9 0.4 1.3 0.8 4.9 0.4 226 18 242 255 10.2 0 10.3 10.1 06/20/2005 03:00:00 3 0.7 4.6 1.1 2.8 0.8 4.9 0.7 1.9 0.8 4.2 0.4 226 13 232 255 10 0 10.1 9.8 06/20/2005 03:10:00 3.3 0.8 5.3 1.1 3.2 0.8 5.3 0.7 2.2 0.8 4.6 0.4 223 17 211 255 9.9 0 10.1 9.8 06/20/2005 03:20:00 3.1 1 5.3 0.7 2.9 1 5.3 0.4 2 0.9 3.8 0.4 213 15 238 255 9.7 0 9.8 9.6 06/20/2005 03:30:00 2.6 0.6 4.2 0.7 2.4 0.7 4.2 0.4 1.6 0.8 4.2 0.4 220 17 223 255 9.4 0 9.6 9.3 06/20/2005 03:40:00 2.9 0.8 5.3 1.5 2.7 0.9 5.3 1.5 1.7 0.9 4.2 0.4 219 18 229 255 9.2 0 9.3 9 06/20/2005 03:50:00 2.4 0.5 3.8 1.1 2 0.5 3.4 0.7 1.1 0.5 2.3 0.4 219 14 204 255 9.1 0 9.3 9 06/20/2005 04:00:00 2.3 0.7 4.6 1.1 2.1 0.7 4.2 0.4 1 0.7 3.4 0.4 216 20 238 255 9 0 9 9 06/20/2005 04:10:00 1.6 0.6 3 0.4 1.2 0.7 3 0.4 0.5 0.3 2.3 0.4 212 15 205 255 9 0 9 9 06/20/2005 04:20:00 1.3 0.7 3.4 0.4 0.9 0.7 3.4 0.4 0.5 0.4 2.6 0.4 224 17 204 255 9 0 9 9 06/20/2005 04:30:00 1.3 0.5 2.3 0.4 0.9 0.5 2.6 0.4 0.4 0.2 1.5 0.4 216 14 211 255 9 0 9 9 06/20/2005 04:40:00 1.9 0.5 3 0.4 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 207 8 206 255 9 0 9 9 06/20/2005 04:50:00 2.2 0.5 3 0.7 2 0.5 3 0.4 1.1 0.6 2.6 0.4 205 11 202 255 9 0 9.3 9 06/20/2005 05:00:00 2.1 0.5 3 0.7 1.8 0.6 3 0.4 0.8 0.5 2.3 0.4 209 10 216 255 9.1 0 9.3 9 06/20/2005 05:10:00 1.8 0.4 3 0.7 1.4 0.5 2.6 0.4 0.6 0.4 2.3 0.4 210 13 212 255 9.2 0 9.3 9 06/20/2005 05:20:00 1.4 0.4 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.9 0.4 211 12 202 255 9.2 0 9.3 9 06/20/2005 05:30:00 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 203 1 204 255 9.3 0 9.3 9.3 06/20/2005 05:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 203 1 202 255 9.4 0 9.6 9.3 06/20/2005 05:50:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.5 0.4 213 9 226 255 9.5 0 9.6 9.3 06/20/2005 06:00:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 203 8 214 255 9.7 0 9.8 9.6 06/20/2005 06:10:00 1.5 0.6 3 0.4 1 0.7 2.6 0.4 0.5 0.4 2.3 0.4 214 14 244 255 10 0 10.1 9.8 06/20/2005 06:20:00 1.9 0.6 3.4 0.4 1.6 0.7 3.4 0.4 0.9 0.6 2.6 0.4 217 17 218 255 10.1 0 10.3 10.1 06/20/2005 06:30:00 1.5 0.8 3.4 0.4 1.2 0.8 3.4 0.4 0.7 0.6 2.6 0.4 210 19 233 255 10.3 0 10.6 10.3 06/20/2005 06:40:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.1 0.4 220 22 225 255 10.5 0 10.9 10.3 06/20/2005 06:50:00 1.3 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.6 0.4 2.3 0.4 228 12 235 255 10.7 0 10.9 10.6 06/20/2005 07:00:00 1.8 0.6 3.4 0.4 1.4 0.7 3 0.4 0.9 0.7 3 0.4 218 16 223 255 10.9 0 10.9 10.9 06/20/2005 07:10:00 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 217 18 229 255 10.9 0 10.9 10.9 06/20/2005 07:20:00 2.1 0.5 3 0.4 1.8 0.6 3 0.4 1.2 0.6 2.6 0.4 218 15 220 255 10.9 0 11.1 10.9 06/20/2005 07:30:00 2.1 0.7 3.8 0.7 1.7 0.9 3.4 0.4 1.2 0.7 3 0.4 214 15 225 255 11 0 11.1 10.9 06/20/2005 07:40:00 1.4 0.6 3 0.4 1 0.7 3 0.4 0.7 0.5 2.3 0.4 211 19 215 255 11.2 0 11.4 11.1 06/20/2005 07:50:00 1.2 0.8 3 0.4 0.9 0.7 3 0.4 0.7 0.5 2.3 0.4 214 16 223 255 11.5 0 11.7 11.4 06/20/2005 08:00:00 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 232 17 212 255 11.9 0.1 12.2 11.7 06/20/2005 08:10:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 213 41 194 255 12.3 0 12.5 11.9 06/20/2005 08:20:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 176 23 180 255 12.3 0 12.5 12.2 06/20/2005 08:30:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 195 27 223 255 12.1 0 12.2 11.9 06/20/2005 08:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 187 17 188 255 12.2 0 12.2 11.9 06/20/2005 08:50:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 202 43 212 255 12.3 0 13 12.2 06/20/2005 09:00:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 213 33 225 255 12.7 0.1 13.3 12.5 06/20/2005 09:10:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 232 32 232 255 12.8 0 13.3 12.7 06/20/2005 09:20:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 238 30 214 255 12.9 0 13.3 12.7 06/20/2005 09:30:00 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.4 1.9 0.4 235 32 249 255 12.9 0.1 13.5 12.7 06/20/2005 09:40:00 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 229 20 250 255 13.2 0 13.8 13 06/20/2005 09:50:00 0.6 0.6 3 0.4 0.5 0.5 3 0.4 0.5 0.3 1.9 0.4 276 58 196 255 13.5 0.1 13.8 13 06/20/2005 10:00:00 1.1 0.6 3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 214 35 189 255 13.6 0.2 14.4 13.3 06/20/2005 10:10:00 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 251 39 293 255 13.7 0.1 14.1 13.5 06/20/2005 10:20:00 1 0.7 3 0.4 0.8 0.7 2.6 0.4 0.6 0.4 2.3 0.4 213 36 229 255 14.2 0.3 15.2 13.5 06/20/2005 10:30:00 1.6 0.7 3 0.4 1.3 0.8 2.6 0.4 1.2 0.7 3 0.4 200 49 235 255 14.8 0.1 15.5 14.6 06/20/2005 10:40:00 1.7 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.1 0.7 3.4 0.4 185 30 208 255 14.8 0 15.2 14.6 06/20/2005 10:50:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.5 2.3 0.4 146 32 131 255 14.7 0 15.2 14.6 06/20/2005 11:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.3 1.9 0.4 115 45 156 255 14.5 0 14.9 14.4 06/20/2005 11:10:00 1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.3 2.3 0.4 260 69 174 255 14.6 0 15.2 14.6 06/20/2005 11:20:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 358 20 22 255 14.7 0 15.5 14.6 06/20/2005 11:30:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 286 72 256 255 14.5 0 15.2 14.4 06/20/2005 11:40:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 263 86 299 255 14.4 0 14.9 14.1 06/20/2005 11:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 15 79 266 255 14.2 0 14.9 14.1 06/20/2005 12:00:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 352 19 357 255 14.2 0 14.6 14.1 06/20/2005 12:10:00 0.8 0.5 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 347 8 351 255 14.3 0 14.9 14.1 06/20/2005 12:20:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 335 13 322 255 14.4 0 14.9 14.4 06/20/2005 12:30:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 323 13 313 255 14.5 0.1 15.2 14.4 06/20/2005 12:40:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 338 11 341 255 14.6 0.1 15.2 14.6 06/20/2005 12:50:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.4 2.3 0.4 320 10 331 255 14.6 0.1 15.2 14.6 06/20/2005 13:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 319 17 290 255 14.6 0 15.2 14.6 06/20/2005 13:10:00 0.7 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.4 0.2 1.5 0.4 17 69 306 255 14.8 0 15.2 14.6 06/20/2005 13:20:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 281 35 247 255 15 0 15.7 14.9 06/20/2005 13:30:00 1.4 0.7 3 0.4 1.1 0.7 3 0.4 0.9 0.7 2.6 0.4 246 21 236 255 15.8 0 16.3 15.5 06/20/2005 13:40:00 1.1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.6 0.4 2.3 0.4 290 61 331 255 16 0.2 16.8 15.7 06/20/2005 13:50:00 1.7 0.7 3.8 0.4 1.5 0.8 3.8 0.4 1.1 0.7 3 0.4 259 58 230 255 16.8 0.4 17.4 16 06/20/2005 14:00:00 1 1 4.6 0.4 0.9 1 4.6 0.4 0.7 0.7 4.2 0.4 230 90 219 255 17.3 0.2 17.7 16.8 06/20/2005 14:10:00 2.6 0.7 4.6 0.4 2.5 0.8 4.6 0.4 2 0.9 4.2 0.4 245 41 255 255 17.8 0.3 18.5 17.1 06/20/2005 14:20:00 2.2 0.8 4.6 0.4 2 0.9 4.6 0.4 1.7 0.9 3.8 0.4 244 64 181 255 18 0.2 18.8 17.7 06/20/2005 14:30:00 1.6 0.6 2.6 0.4 1.4 0.7 3 0.4 1.2 0.7 3 0.4 91 117 144 255 18.5 0.1 19.1 18.2 06/20/2005 14:40:00 2.3 0.9 4.2 0.4 2.2 0.9 4.2 0.4 1.8 0.9 4.6 0.4 199 32 205 255 19 0 19.4 18.5 06/20/2005 14:50:00 2.1 0.6 3.8 0.4 2.1 0.7 3.8 0.4 2 0.7 4.2 0.4 171 19 141 255 17.9 0.7 19.4 16.8 06/20/2005 15:00:00 1.8 0.7 3.8 0.4 1.6 0.8 3.4 0.4 1.4 0.7 3.8 0.4 220 29 192 255 17 0 17.4 16.8 06/20/2005 15:10:00 1 0.6 2.3 0.4 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 256 39 327 255 17.1 0 17.4 16.8 06/20/2005 15:20:00 1.5 0.7 3 0.4 1.3 0.7 3 0.4 1.2 0.8 3 0.4 274 28 273 255 17.1 0 17.7 16.8 06/20/2005 15:30:00 1.4 0.6 3.4 0.4 1.3 0.7 3.4 0.4 0.9 0.6 3.4 0.4 246 49 303 255 17.3 0.1 17.7 16.8 06/20/2005 15:40:00 1.2 0.7 3.4 0.4 1.1 0.7 3.4 0.4 1 0.6 3 0.4 246 29 255 255 17.2 0 17.7 16.8 06/20/2005 15:50:00 2 0.9 3.4 0.4 1.9 0.9 3.4 0.4 1.7 0.8 3.4 0.4 231 24 218 255 17.2 0.1 18 16.8 06/20/2005 16:00:00 1.6 0.8 3.4 0.4 1.6 0.8 3.8 0.4 1.4 0.6 3.8 0.4 226 58 196 255 17.8 0.1 18.2 17.4 06/20/2005 16:10:00 1.7 0.6 3 0.4 1.6 0.7 3 0.4 1.6 0.6 3 0.4 154 23 146 255 17.3 0.4 18.2 16.8 06/20/2005 16:20:00 1 0.5 2.6 0.4 0.8 0.6 2.6 0.4 0.8 0.5 3 0.4 168 36 167 255 16.9 0.2 17.7 16.8 06/20/2005 16:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.4 1.9 0.4 229 51 189 255 17.3 0 17.7 16.8 06/20/2005 16:40:00 1.9 0.9 3.4 0.4 1.8 0.9 3.8 0.4 1.4 0.9 3.8 0.4 306 17 284 255 17.5 0.1 18.2 17.1 06/20/2005 16:50:00 2.3 0.5 3.4 0.7 2.1 0.6 3.8 0.4 1.4 0.7 3 0.4 348 27 327 255 18.2 0.1 18.8 17.7 06/20/2005 17:00:00 1.9 0.6 3.4 0.7 1.8 0.7 3.4 0.4 1.6 0.6 3.4 0.4 309 30 352 255 18.1 0.2 18.5 17.7 06/20/2005 17:10:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 317 39 337 255 17.7 0.2 18.2 17.4 06/20/2005 17:20:00 1.4 0.8 3.8 0.4 1.2 0.8 3.8 0.4 1 0.7 3 0.4 307 69 322 255 18 0.1 18.5 17.7 06/20/2005 17:30:00 1.8 0.5 3.4 0.4 1.7 0.6 3 0.4 1.4 0.6 2.6 0.4 265 22 279 255 17.9 0 18.2 17.7 06/20/2005 17:40:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 319 47 37 255 17.8 0 18.2 17.4 06/20/2005 17:50:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 0.7 0.4 2.3 0.4 16 27 4 255 17.8 0.1 18.2 17.4 06/20/2005 18:00:00 2 0.6 3.8 0.7 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 357 19 345 255 17.9 0 18.2 17.7 06/20/2005 18:10:00 1.3 0.6 2.6 0.4 1.3 0.7 2.6 0.4 1 0.6 2.6 0.4 4 20 349 255 18 0.1 18.2 17.7 06/20/2005 18:20:00 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 17 51 292 255 17.9 0 18.2 17.7 06/20/2005 18:30:00 1.4 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 251 21 264 255 17.8 0.1 18.2 17.4 06/20/2005 18:40:00 1.2 0.6 2.3 0.4 1.2 0.6 2.3 0.4 0.9 0.5 2.3 0.4 183 38 219 255 17.8 0 18.2 17.4 06/20/2005 18:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 134 41 146 255 17.4 0.1 18 17.1 06/20/2005 19:00:00 0.8 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.5 0.4 217 21 205 255 17.2 0 17.7 17.1 06/20/2005 19:10:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 176 22 181 255 17.3 0.1 17.7 16.8 06/20/2005 19:20:00 0.5 0.4 1.9 0.4 0.5 0.4 1.5 0.4 0.4 0.2 1.1 0.4 149 0 149 255 17.3 0 17.4 17.1 06/20/2005 19:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 225 56 256 255 17.5 0 17.7 17.4 06/20/2005 19:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 282 2 278 255 17.5 0.1 17.7 17.1 06/20/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 255 255 17.3 0 17.4 17.1 06/20/2005 20:00:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 345 56 20 255 17 0 17.1 16.8 06/20/2005 20:10:00 1.2 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 18 12 33 255 16.6 0 16.8 16.6 06/20/2005 20:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 6 12 27 255 16.3 0.1 16.8 16.3 06/20/2005 20:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 346 14 354 255 15.9 0 16.3 15.5 06/20/2005 20:40:00 1.3 0.6 2.6 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.6 0.4 341 27 35 255 15.2 0.2 15.7 14.9 06/20/2005 20:50:00 2.3 0.6 3.4 1.1 2.2 0.6 3.8 1.1 1.5 0.9 3.4 0.4 27 12 47 255 14.7 0 15.2 14.4 06/20/2005 21:00:00 2.3 0.5 3.8 1.1 2.2 0.5 3.4 1.1 1.6 0.7 3 0.4 22 10 0 255 14.4 0 14.6 13.8 06/20/2005 21:10:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.2 0.7 2.6 0.4 36 24 21 255 13.9 0 14.6 13.5 06/20/2005 21:20:00 1.5 0.4 2.3 0.4 1.6 0.4 2.3 0.7 1 0.5 2.3 0.4 55 7 59 255 13.9 0 14.4 13.5 06/20/2005 21:30:00 2.3 0.4 3 1.1 2.3 0.4 3 1.1 1.7 0.6 3 0.4 31 8 34 255 13.5 0.2 14.1 13 06/20/2005 21:40:00 1.4 0.4 2.6 0.4 1.4 0.4 2.3 0.4 0.6 0.4 1.9 0.4 36 13 21 255 12.8 0.3 13.5 12.2 06/20/2005 21:50:00 1.9 0.4 2.6 0.7 1.9 0.4 3 0.7 1.1 0.4 2.3 0.4 48 6 41 255 12.1 0.1 12.7 11.9 06/20/2005 22:00:00 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.1 0.5 2.3 0.4 53 10 51 255 11.7 0 11.9 11.7 06/20/2005 22:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.7 0.4 2.3 0.4 37 11 35 255 11.3 0.1 11.9 11.1 06/20/2005 22:20:00 1.8 0.4 3 1.1 1.8 0.4 3 0.7 1.1 0.4 2.3 0.4 49 9 58 255 11 0 11.4 10.9 06/20/2005 22:30:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 1.7 0.4 2.6 0.7 61 6 66 255 10.9 0 11.4 10.9 06/20/2005 22:40:00 2.4 0.4 3.4 1.5 2.4 0.4 3.8 1.1 1.4 0.5 2.6 0.4 62 8 58 255 10.9 0 10.9 10.9 06/20/2005 22:50:00 2 0.4 3 1.1 2 0.5 3.4 1.1 0.9 0.5 2.3 0.4 63 9 62 255 10.5 0.1 10.9 10.3 06/20/2005 23:00:00 2 0.4 3 1.1 2 0.4 3 1.1 1.1 0.5 2.3 0.4 65 10 62 255 10 0 10.3 9.8 06/20/2005 23:10:00 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 0.9 0.5 2.3 0.4 68 9 68 255 9.6 0 10.3 9.3 06/20/2005 23:20:00 2.4 0.5 4.2 1.1 2.4 0.6 4.2 1.1 1.1 0.5 2.6 0.4 62 9 60 255 9.4 0 9.8 9.3 06/20/2005 23:30:00 2.3 0.5 3.8 1.1 2.2 0.5 3.4 1.1 1.1 0.5 2.6 0.4 68 10 46 255 9.1 0 9.6 8.8 06/20/2005 23:40:00 2.2 0.4 3.4 1.1 2.2 0.4 3.4 1.1 1 0.6 2.6 0.4 72 12 68 255 8.7 0 9 8.8 06/20/2005 23:50:00 2.3 0.6 3.8 0.7 2.2 0.6 3.8 0.4 0.9 0.6 3 0.4 74 10 91 255 8.6 0 8.8 8.5 06/21/2005 00:00:00 2.1 0.3 3 1.1 2 0.4 3 1.1 0.7 0.5 2.3 0.4 79 10 97 255 8.5 0 9 8.5 06/21/2005 00:10:00 1.8 0.4 3 0.4 1.7 0.4 2.6 0.7 0.4 0.2 1.9 0.4 94 12 87 255 8.5 0 8.8 8.5 06/21/2005 00:20:00 2.3 0.5 3.4 0.7 2.2 0.5 3 0.4 1 0.5 2.3 0.4 103 8 103 255 8.5 0 8.8 8.5 06/21/2005 00:30:00 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.5 1.6 0.6 2.6 0.4 110 10 111 255 8.4 0 8.5 8.3 06/21/2005 00:40:00 2.3 0.5 3.4 0.7 2.1 0.6 3.4 0.4 1.1 0.5 2.6 0.4 118 12 107 255 8.1 0 8.5 8 06/21/2005 00:50:00 2.2 0.6 3.8 0.4 2.1 0.6 3.4 0.4 0.9 0.5 2.3 0.4 112 11 109 255 8.1 0 8.3 8 06/21/2005 01:00:00 2.7 0.5 3.8 1.1 2.6 0.6 3.8 1.1 1.5 0.5 3 0.4 102 9 92 255 8.2 0 8.5 8 06/21/2005 01:10:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.1 1.3 0.6 2.6 0.4 102 9 106 255 8.1 0 8.3 8 06/21/2005 01:20:00 2.4 0.5 3.4 0.7 2.3 0.5 3.4 0.7 1.1 0.5 2.6 0.4 113 10 100 255 8 0 8.3 7.8 06/21/2005 01:30:00 2.4 0.5 3.4 1.1 2.4 0.5 3.4 1.1 1.4 0.5 2.6 0.4 120 11 112 255 7.9 0 8 7.8 06/21/2005 01:40:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.3 0.6 3 0.4 125 14 108 255 8.3 0.1 8.5 8 06/21/2005 01:50:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 1.3 0.4 2.3 0.4 121 13 122 255 8.3 0 8.5 8 06/21/2005 02:00:00 2.4 0.6 3.8 0.7 2.3 0.6 3.4 1.1 1.6 0.5 3 0.4 127 12 129 255 8.1 0 8.5 8 06/21/2005 02:10:00 2.6 0.7 4.2 1.1 2.5 0.7 4.2 0.7 1.6 0.6 3.4 0.4 121 14 110 255 8.3 0 8.5 8.3 06/21/2005 02:20:00 2.7 0.8 4.6 0.7 2.6 0.8 4.6 0.7 1.5 0.7 3.4 0.4 119 15 99 255 8.4 0 8.5 8.3 06/21/2005 02:30:00 1.6 0.7 3.4 0.4 1.4 0.8 3.4 0.4 0.6 0.4 2.3 0.4 118 22 127 255 8.3 0 8.5 8.3 06/21/2005 02:40:00 2.4 0.6 3.8 1.1 2.3 0.6 3.8 0.7 1.1 0.5 2.6 0.4 109 11 105 255 8.1 0.1 8.3 7.8 06/21/2005 02:50:00 3.3 0.4 4.2 1.9 3.3 0.4 3.8 2.3 2.1 0.6 3.4 0.4 108 8 102 255 7.9 0 8 7.8 06/21/2005 03:00:00 3.3 0.5 4.6 1.5 3.2 0.5 4.2 1.1 1.9 0.6 3.4 0.4 106 9 104 255 8 0 8.3 7.8 06/21/2005 03:10:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.9 1.7 0.6 3 0.4 100 10 102 255 7.8 0 8 7.8 06/21/2005 03:20:00 3 0.4 3.8 1.5 3 0.4 4.2 1.9 1.9 0.6 3 0.4 106 10 96 255 8 0 8.3 7.8 06/21/2005 03:30:00 2.5 0.6 3.8 1.1 2.4 0.6 3.8 0.7 1.2 0.6 2.6 0.4 116 13 117 255 7.8 0 8.3 7.5 06/21/2005 03:40:00 2.4 0.6 3.8 0.7 2.4 0.6 3.8 0.7 1.2 0.6 3 0.4 118 17 142 255 7.5 0 7.8 7.5 06/21/2005 03:50:00 2.4 0.6 3.8 0.4 2.3 0.6 3.8 0.4 0.9 0.6 2.6 0.4 111 14 122 255 7.8 0 7.8 7.5 06/21/2005 04:00:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.5 1.8 0.7 3.8 0.4 111 12 124 255 7.9 0 8.3 7.8 06/21/2005 04:10:00 3.1 0.7 4.9 1.5 3 0.7 4.6 1.1 1.8 0.8 4.2 0.4 113 15 115 255 8.3 0 8.5 8.3 06/21/2005 04:20:00 2.6 0.6 3.8 1.1 2.4 0.7 4.2 0.4 1.2 0.7 3.4 0.4 114 15 124 255 8.6 0 8.8 8.5 06/21/2005 04:30:00 3.1 0.6 4.6 1.5 2.9 0.7 4.6 1.1 1.9 0.8 3.8 0.4 113 14 106 255 8.7 0 9 8.5 06/21/2005 04:40:00 3.3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 1.9 0.8 3.8 0.4 109 12 104 255 9.2 0.2 9.6 9 06/21/2005 04:50:00 2.8 0.6 4.2 0.7 2.6 0.7 4.2 0.7 1.6 0.7 3.4 0.4 111 17 86 255 9.6 0.1 9.8 9.6 06/21/2005 05:00:00 3 0.7 4.9 1.1 2.9 0.8 4.9 0.4 2.1 0.8 3.8 0.4 109 12 117 255 10.2 0.1 10.6 9.8 06/21/2005 05:10:00 3.6 0.7 5.3 1.9 3.4 0.7 4.9 1.9 2.3 0.8 4.9 0.4 112 17 94 255 10.8 0 11.1 10.6 06/21/2005 05:20:00 3.3 0.8 5.7 1.5 3.2 0.8 5.3 1.1 2.5 1 4.9 0.4 112 15 122 255 11.1 0 11.1 11.1 06/21/2005 05:30:00 3.4 0.7 4.9 1.1 3.3 0.7 4.9 1.5 2.2 1 4.6 0.4 108 15 104 255 11.2 0 11.4 11.1 06/21/2005 05:40:00 3.5 0.8 5.3 1.5 3.4 0.9 4.9 1.5 2.7 0.8 4.6 0.4 112 17 124 255 11.3 0 11.7 11.1 06/21/2005 05:50:00 3 0.7 4.9 1.5 2.9 0.8 5.3 0.7 2.1 0.9 4.6 0.4 108 15 102 255 11.9 0.2 12.2 11.4 06/21/2005 06:00:00 2.9 0.7 4.2 1.1 2.7 0.8 4.2 0.4 2 0.9 4.2 0.4 108 15 108 255 12.5 0 12.7 12.2 06/21/2005 06:10:00 2.5 0.6 3.8 0.7 2.4 0.6 3.8 0.4 1.9 0.6 3.4 0.4 103 15 88 255 12.8 0 13 12.7 06/21/2005 06:20:00 2.8 0.6 4.2 1.1 2.6 0.7 4.2 0.7 2.1 0.8 4.2 0.4 105 14 84 255 13.2 0 13.5 13 06/21/2005 06:30:00 2.6 0.7 4.9 1.1 2.4 0.8 4.6 0.4 1.8 0.8 4.2 0.4 96 15 97 255 13.5 0.1 13.8 13.3 06/21/2005 06:40:00 2.8 0.6 4.2 1.1 2.6 0.7 4.2 0.7 2.4 0.7 3.8 0.7 104 12 101 255 13.9 0.1 14.6 13.8 06/21/2005 06:50:00 2.3 0.6 4.2 0.4 2.1 0.7 3.8 0.4 1.7 0.6 3 0.4 101 13 100 255 14.1 0.1 14.6 13.8 06/21/2005 07:00:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.5 2.6 0.4 84 27 103 255 14.5 0.2 15.5 14.1 06/21/2005 07:10:00 1.7 0.6 3 0.4 1.4 0.7 3 0.4 1.3 0.7 3 0.4 64 16 74 255 15.1 0.1 15.7 14.9 06/21/2005 07:20:00 1.4 0.5 2.3 0.4 1.2 0.5 1.9 0.4 1.2 0.5 2.3 0.4 75 12 86 255 15.6 0 16.3 15.5 06/21/2005 07:30:00 1.4 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 75 30 109 255 15.5 0 16.3 15.5 06/21/2005 07:40:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 30 17 8 255 16.1 0.4 16.8 15.5 06/21/2005 07:50:00 1.3 0.7 3.4 0.4 1.1 0.7 3.4 0.4 1 0.6 2.6 0.4 48 35 29 255 16.8 0 17.1 16.6 06/21/2005 08:00:00 2.2 0.5 3.4 1.1 2 0.5 3.4 0.7 1.7 0.5 3 0.4 33 15 37 255 17.2 0 17.7 16.8 06/21/2005 08:10:00 2.2 0.5 3.4 1.1 2 0.5 3 0.7 1.6 0.6 3 0.4 18 14 37 255 17.8 0.2 18.5 17.1 06/21/2005 08:20:00 1.8 0.6 3.4 0.7 1.5 0.8 3.4 0.4 1.5 0.6 3.8 0.4 27 21 17 255 17.9 0 18.2 17.7 06/21/2005 08:30:00 2.3 0.6 3.4 0.7 2 0.7 3.8 0.4 1.5 0.8 3 0.4 18 27 33 255 18 0.2 18.5 17.7 06/21/2005 08:40:00 2.6 0.5 4.2 1.1 2.5 0.5 4.2 1.1 2.1 0.6 4.9 0.7 37 28 32 255 18.5 0.2 19.1 18.2 06/21/2005 08:50:00 1.9 0.6 3 0.4 1.7 0.7 3 0.4 1.5 0.7 3 0.4 39 24 51 255 18.2 0.1 18.8 18 06/21/2005 09:00:00 1.6 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.5 0.4 2.3 0.4 47 15 48 255 18.4 0.1 18.8 18 06/21/2005 09:10:00 1.7 0.7 3.4 0.4 1.5 0.7 3.8 0.4 1.4 0.7 3.4 0.4 9 32 22 255 18.6 0.3 19.7 18 06/21/2005 09:20:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 15 20 57 255 19.1 0.1 19.7 18.8 06/21/2005 09:30:00 1.3 0.9 3.4 0.4 1.2 0.8 3.8 0.4 1.2 0.7 3.4 0.4 326 53 358 255 19.2 0 19.7 19.1 06/21/2005 09:40:00 1.2 0.5 2.6 0.4 1.1 0.6 2.3 0.4 1 0.5 2.3 0.4 336 43 314 255 19.2 0 19.7 19.1 06/21/2005 09:50:00 1.6 0.6 3 0.4 1.5 0.7 3.4 0.4 1.5 0.6 2.6 0.4 331 41 294 255 19.2 0 19.4 18.8 06/21/2005 10:00:00 1.3 0.7 3.4 0.4 1.2 0.7 3.4 0.4 1.2 0.7 3.4 0.4 15 43 24 255 19.2 0 19.4 19.1 06/21/2005 10:10:00 2.1 0.7 3.4 0.4 2.1 0.7 3.8 0.4 1.5 0.7 3.4 0.4 4 23 352 255 20 0.2 20.5 19.4 06/21/2005 10:20:00 2.1 0.7 3.8 0.4 1.9 0.7 3.4 0.4 1.5 0.7 3.4 0.4 356 26 340 255 20.3 0.1 20.5 20 06/21/2005 10:30:00 1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 1 0.6 3 0.4 234 58 290 255 20 0.1 20.5 19.7 06/21/2005 10:40:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 263 45 289 255 19.8 0 20.3 19.4 06/21/2005 10:50:00 1.5 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.3 0.5 3.4 0.4 246 35 289 255 20.2 0.1 20.5 20 06/21/2005 11:00:00 2.1 0.6 3.4 0.4 2.1 0.6 3.8 0.4 2 0.7 3.8 0.4 299 18 310 255 20.5 0 20.8 20.3 06/21/2005 11:10:00 2.3 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.9 0.9 3.8 0.4 288 33 284 255 21.3 0.4 22.3 20.5 06/21/2005 11:20:00 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.2 0.7 3.4 0.4 301 64 313 255 21.7 0 22.3 21.4 06/21/2005 11:30:00 2.1 0.8 3.8 0.4 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 295 26 314 255 21.5 0 21.7 21.1 06/21/2005 11:40:00 1.8 0.8 3.4 0.4 1.8 0.8 3.4 0.4 1.4 0.7 3.4 0.4 302 30 326 255 20.8 0.2 21.4 20.5 06/21/2005 11:50:00 1.9 1 3.8 0.4 1.8 1 4.2 0.4 1.5 1 4.2 0.4 285 61 278 255 21.3 0.2 22 20.8 06/21/2005 12:00:00 2 0.8 4.2 0.4 2 0.8 3.8 0.4 1.8 0.9 3.8 0.4 288 23 318 255 21.6 0.3 22.3 21.1 06/21/2005 12:10:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 231 51 255 255 21.9 0.1 22.3 21.4 06/21/2005 12:20:00 2.1 1 4.2 0.4 2.1 0.9 4.6 0.4 1.7 0.9 4.9 0.4 282 38 263 255 22.3 0 22.6 22 06/21/2005 12:30:00 1.3 0.8 3 0.4 1.3 0.8 3 0.4 1.1 0.6 2.6 0.4 292 90 327 255 22.5 0.1 22.9 22 06/21/2005 12:40:00 1.6 0.8 3 0.4 1.5 0.8 3 0.4 1.3 0.7 3.4 0.4 240 107 333 255 22.4 0.2 22.9 22 06/21/2005 12:50:00 1.3 0.7 2.6 0.4 1.2 0.7 3 0.4 1.2 0.7 2.6 0.4 294 72 314 255 23 0 23.2 22.9 06/21/2005 13:00:00 2.2 1 4.6 0.4 2.1 1 4.9 0.4 1.6 0.9 3.4 0.4 357 23 3 255 23.2 0 23.5 22.9 06/21/2005 13:10:00 2.7 1.4 6.1 0.4 2.6 1.5 6.1 0.4 2.2 1.1 4.9 0.4 16 27 351 255 23.1 0 23.5 22.9 06/21/2005 13:20:00 2 0.7 3.4 0.4 2 0.7 3.8 0.4 1.8 0.6 3.4 0.4 24 32 20 255 23.1 0 23.5 23.2 06/21/2005 13:30:00 1.9 0.8 4.2 0.4 1.8 0.7 3.8 0.4 1.5 0.8 3.8 0.4 330 61 315 255 23.6 0.3 24.1 23.2 06/21/2005 13:40:00 2.3 0.7 3.8 0.4 2.2 0.7 3.8 0.4 1.9 0.8 3.8 0.4 335 26 308 255 24.2 0 24.4 24.1 06/21/2005 13:50:00 1.8 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.5 0.8 3.8 0.4 316 47 7 255 24.7 0.2 25 24.4 06/21/2005 14:00:00 2.4 1.3 5.3 0.4 2.4 1.3 4.9 0.4 2 1.2 4.6 0.4 296 53 329 255 24.7 0 25 24.7 06/21/2005 14:10:00 2.4 0.9 4.6 0.4 2.3 1 4.2 0.4 2.1 0.9 4.2 0.4 297 33 304 255 24.4 0 24.7 24.1 06/21/2005 14:20:00 2.5 0.8 4.9 0.4 2.6 0.8 4.6 0.4 2.3 0.8 3.8 0.4 272 30 263 255 23.9 0.4 24.7 23.5 06/21/2005 14:30:00 2.7 1.2 5.3 0.4 2.7 1.1 4.9 0.4 2.4 1.1 5.3 0.7 321 26 282 255 23.6 0.2 24.1 23.5 06/21/2005 14:40:00 2.3 0.7 4.2 0.7 2.3 0.7 4.2 0.7 1.8 0.7 3.4 0.4 292 26 252 255 24 0.2 24.4 23.5 06/21/2005 14:50:00 2.8 0.8 4.9 1.1 2.7 0.8 4.6 0.7 2.1 0.9 4.6 0.4 331 33 293 255 24.4 0 24.7 23.8 06/21/2005 15:00:00 3 0.8 4.9 0.4 3 0.8 4.9 0.4 2.6 0.8 4.6 0.4 301 32 267 255 24.7 0 25 24.7 06/21/2005 15:10:00 2.5 0.7 4.6 1.1 2.5 0.7 4.6 0.7 2.1 0.8 3.8 0.4 299 19 301 255 24.5 0 24.7 24.4 06/21/2005 15:20:00 3.1 0.9 4.9 0.7 3.1 0.9 4.9 0.7 2.5 1 4.9 0.4 299 18 306 255 24.1 0.1 24.4 23.8 06/21/2005 15:30:00 2.5 0.7 4.9 1.1 2.4 0.7 4.9 0.7 2.1 0.9 3.8 0.4 298 28 300 255 24.3 0.2 24.7 23.5 06/21/2005 15:40:00 2.5 0.8 4.9 0.7 2.5 0.9 4.9 0.4 2.2 0.8 4.2 0.7 291 21 279 255 23.1 0.2 23.8 22.9 06/21/2005 15:50:00 2.4 0.7 4.2 0.7 2.4 0.7 3.8 0.4 2.2 0.9 4.2 0.4 295 16 305 255 23.7 0 23.8 23.5 06/21/2005 16:00:00 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.7 0.6 3 0.4 312 38 290 255 23.4 0 23.8 23.2 06/21/2005 16:10:00 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1 0.4 1.9 0.4 276 58 266 255 23.8 0 24.1 23.8 06/21/2005 16:20:00 1.6 0.6 3.4 0.4 1.5 0.6 3.4 0.4 1.4 0.5 3 0.4 202 33 201 255 24.2 0.1 24.4 23.8 06/21/2005 16:30:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 1 0.6 2.6 0.4 219 45 244 255 23.8 0 24.1 23.5 06/21/2005 16:40:00 1.4 0.8 3 0.4 1.4 0.8 3.4 0.4 1.2 0.7 3 0.4 41 76 355 255 23.7 0 23.8 23.5 06/21/2005 16:50:00 2.9 1.1 5.3 0.4 2.8 1.1 5.3 0.4 2.5 1 4.9 0.4 28 32 31 255 23.8 0 23.8 23.5 06/21/2005 17:00:00 1.6 1 3.4 0.4 1.6 0.9 3.4 0.4 1.3 0.8 3 0.4 68 51 38 255 23.8 0 23.8 23.8 06/21/2005 17:10:00 2.3 0.5 4.6 1.1 2.3 0.6 3.8 0.7 2 0.8 3.8 0.4 19 29 14 255 23.8 0 23.8 23.5 06/21/2005 17:20:00 2.3 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.8 0.8 3.4 0.4 323 23 328 255 23.3 0 23.8 23.2 06/21/2005 17:30:00 1.8 1.1 5.3 0.4 1.7 1.1 5.3 0.4 1.3 0.9 4.6 0.4 311 30 288 255 23 0 23.2 22.9 06/21/2005 17:40:00 2.1 0.5 3.4 0.7 2 0.5 3.4 0.7 1.5 0.6 3 0.4 329 22 23 255 23 0.1 23.5 22.9 06/21/2005 17:50:00 1.2 1 3.4 0.4 1.2 0.9 3 0.4 0.9 0.7 2.6 0.4 15 21 340 255 22.9 0 23.2 22.9 06/21/2005 18:00:00 2.2 1 4.2 0.4 2.2 1 4.2 0.4 2 0.9 3.8 0.4 37 28 26 255 23.1 0.1 23.5 22.9 06/21/2005 18:10:00 1.3 0.7 3.8 0.4 1.1 0.7 3.8 0.4 0.8 0.6 2.6 0.4 344 18 326 255 22.2 0.4 22.9 21.7 06/21/2005 18:20:00 3.4 1.1 4.9 0.4 3.4 1.1 5.3 0.4 2.4 1.1 4.6 0.4 16 15 0 255 21.3 0.2 21.7 20.8 06/21/2005 18:30:00 4.1 0.5 4.9 2.3 4.1 0.5 4.9 2.6 3.1 0.9 4.9 0.7 17 11 22 255 20.6 0 21.1 20.3 06/21/2005 18:40:00 4 0.7 5.7 2.3 4 0.7 6.1 2.3 2.9 0.9 4.9 0.7 16 12 17 255 20.3 0 20.5 20.3 06/21/2005 18:50:00 3.9 0.5 5.3 2.3 3.9 0.6 5.3 2.3 3.2 0.8 4.9 1.1 20 10 26 255 20.3 0 20.5 20.3 06/21/2005 19:00:00 2.9 0.8 4.9 1.1 2.9 0.8 4.9 1.1 2 0.8 4.2 0.4 18 12 23 255 20.1 0 20.5 20 06/21/2005 19:10:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 2.5 1 4.9 0.4 16 12 29 255 20 0 20.5 19.7 06/21/2005 19:20:00 2.9 0.7 4.6 1.1 2.9 0.7 4.9 1.1 2 0.9 4.2 0.4 6 17 17 255 20 0 20.5 20 06/21/2005 19:30:00 2.9 0.7 4.6 1.1 3 0.7 4.6 1.1 2.1 0.8 4.2 0.4 6 14 8 255 19.7 0 20.5 19.7 06/21/2005 19:40:00 3.7 0.7 5.3 1.9 3.7 0.7 5.3 1.5 2.6 0.8 4.6 0.4 13 14 1 255 19.6 0.1 20.3 19.4 06/21/2005 19:50:00 3.1 0.6 4.6 1.9 3 0.6 4.6 1.9 1.7 0.8 3.8 0.4 11 11 6 255 19 0.2 20 18.5 06/21/2005 20:00:00 3.1 0.8 5.7 1.1 3.1 0.8 5.7 1.5 2.1 0.7 4.2 0.4 6 15 7 255 18.5 0.1 18.8 18.2 06/21/2005 20:10:00 3 0.8 4.9 1.1 3.1 0.8 4.9 1.1 2 0.8 4.6 0.4 14 11 9 255 18 0 18.2 17.7 06/21/2005 20:20:00 3.3 0.7 5.7 1.5 3.3 0.7 5.3 1.5 2.1 0.9 4.9 0.4 7 12 17 255 17.7 0 18 17.4 06/21/2005 20:30:00 2.9 0.6 4.6 1.1 2.9 0.6 4.6 1.1 1.2 0.7 3.8 0.4 6 14 20 255 17.3 0 17.4 17.1 06/21/2005 20:40:00 3.1 0.8 5.3 1.5 3.1 0.8 5.3 1.1 1.9 0.8 3.8 0.4 13 17 16 255 17 0.1 17.1 16.8 06/21/2005 20:50:00 1.2 0.7 2.6 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.6 0.4 309 20 13 255 16.8 0 16.8 16.8 06/21/2005 21:00:00 1.8 0.5 3 0.7 1.8 0.5 3 0.7 1.1 0.5 2.6 0.4 19 12 7 255 16.8 0 17.1 16.8 06/21/2005 21:10:00 2.5 0.4 3.8 1.5 2.5 0.5 3.8 1.1 1.6 0.5 2.6 0.4 10 10 26 255 16.5 0.1 16.8 16.3 06/21/2005 21:20:00 2 0.6 3 0.7 1.9 0.6 3 0.4 1 0.5 2.3 0.4 2 12 1 255 15.8 0.2 16.3 15.5 06/21/2005 21:30:00 2.5 0.6 3.8 1.5 2.3 0.6 3.8 1.1 1.5 0.6 3.4 0.4 327 17 325 255 15.1 0.1 15.7 14.9 06/21/2005 21:40:00 2.4 0.4 3.4 1.1 2.1 0.5 3.4 0.7 1.3 0.6 3 0.4 341 12 358 255 14.6 0 15.2 14.6 06/21/2005 21:50:00 3.6 0.6 5.3 2.3 3.5 0.7 5.3 1.5 2.2 0.8 3.8 0.4 312 12 300 255 14.4 0 14.6 14.1 06/21/2005 22:00:00 2.7 0.5 4.6 1.5 2.7 0.5 4.2 1.5 1.6 0.6 2.6 0.4 304 9 326 255 14 0.1 14.6 13.8 06/21/2005 22:10:00 2.2 0.6 3.8 0.7 2.2 0.7 3.8 0.7 1 0.7 2.6 0.4 298 13 289 255 13.9 0 14.4 13.8 06/21/2005 22:20:00 1.7 0.7 3 0.4 1.6 0.7 3 0.4 0.8 0.6 2.3 0.4 267 11 247 255 13.9 0 14.4 13.8 06/21/2005 22:30:00 1.5 0.5 3 0.4 1.5 0.6 3 0.4 0.7 0.4 2.3 0.4 255 8 260 255 13.7 0.1 14.4 13.3 06/21/2005 22:40:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.4 0.2 1.1 0.4 246 11 248 255 13.3 0.1 13.8 13 06/21/2005 22:50:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 0.7 0.4 1.5 0.4 216 7 219 255 12.9 0 13.5 12.5 06/21/2005 23:00:00 3 0.4 3.8 1.9 3 0.4 3.8 2.3 1.7 0.5 2.6 0.4 221 6 211 255 12.5 0 12.7 12.5 06/21/2005 23:10:00 1.6 0.7 3 0.4 1.5 0.7 3 0.4 0.7 0.5 2.3 0.4 235 9 228 255 12.2 0 12.7 11.9 06/21/2005 23:20:00 0.6 0.4 1.5 0.4 0.5 0.4 1.9 0.4 0.4 0 0.4 0.4 244 7 241 255 11.6 0.1 12.2 11.4 06/21/2005 23:30:00 2 0.5 3 1.1 2 0.5 3 1.1 0.9 0.6 2.3 0.4 302 21 318 255 11.1 0 11.7 11.1 06/21/2005 23:40:00 1.3 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.4 0.2 1.1 0.4 296 8 310 255 10.9 0.1 11.4 10.6 06/21/2005 23:50:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.7 0.4 328 14 316 255 10.6 0 11.1 10.6 06/22/2005 00:00:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.1 0.7 0.4 316 16 309 255 10.5 0 11.1 10.3 06/22/2005 00:10:00 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 12 26 4 255 10.1 0.1 10.9 9.8 06/22/2005 00:20:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.7 0.4 1.5 0.4 292 39 4 255 9.8 0 10.3 9.6 06/22/2005 00:30:00 1.9 0.7 3 0.4 1.8 0.8 3 0.4 1.2 0.6 2.3 0.4 352 38 22 255 9.8 0 10.3 9.6 06/22/2005 00:40:00 2.5 0.6 4.2 1.5 2.4 0.6 4.2 1.1 1.4 0.6 3 0.4 281 32 319 255 9.6 0.1 10.3 9.6 06/22/2005 00:50:00 1.4 1 3.4 0.4 1.4 1 3.8 0.4 0.6 0.5 2.6 0.4 223 13 243 255 9.7 0 10.1 9.6 06/22/2005 01:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0 0.4 0.4 204 13 201 255 9.6 0 9.8 9.3 06/22/2005 01:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 294 56 223 255 9.3 0 9.6 9.3 06/22/2005 01:20:00 2.3 0.5 3.4 0.7 2.3 0.5 3.4 0.7 1 0.4 1.9 0.4 221 9 220 255 9.2 0 9.3 9 06/22/2005 01:30:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.1 0.7 0.4 222 6 219 255 9 0 9.3 9 06/22/2005 01:40:00 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.6 0.4 1.5 0.4 128 79 16 255 8.8 0 9 8.5 06/22/2005 01:50:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.5 0.3 1.9 0.4 132 82 248 255 8.5 0 8.8 8.5 06/22/2005 02:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 209 0 209 255 8.5 0 8.5 8.5 06/22/2005 02:10:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 203 5 206 255 8.4 0 9 8.3 06/22/2005 02:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 212 66 43 255 8.1 0 8.5 8 06/22/2005 02:30:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 25 2 43 255 8 0 8.3 7.8 06/22/2005 02:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 45 27 80 255 7.8 0 8 7.8 06/22/2005 02:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 81 255 7.7 0 7.8 7.5 06/22/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 81 0 255 255 7.6 0 7.8 7.5 06/22/2005 03:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 78 4 71 255 7.6 0 7.8 7.5 06/22/2005 03:20:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0 0.4 0.4 66 12 40 255 7.4 0 7.8 7.3 06/22/2005 03:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 40 0 40 255 7.3 0 7.5 7.3 06/22/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 255 255 7.3 0 7.5 7.3 06/22/2005 03:50:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.9 0.4 114 90 220 255 7.3 0 7.5 7.3 06/22/2005 04:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 169 17 158 255 7.3 0 7.5 7.3 06/22/2005 04:10:00 0.5 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 112 33 100 255 7.4 0 7.5 7.3 06/22/2005 04:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 107 0 107 255 7.3 0 7.5 7.3 06/22/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 107 0 255 255 7.4 0 7.5 7.3 06/22/2005 04:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.5 1.9 0.4 129 17 144 255 7.7 0 7.8 7.5 06/22/2005 04:50:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.5 1.9 0.4 150 6 144 255 8 0 8.3 7.8 06/22/2005 05:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 161 0 161 255 8.3 0 8.5 8.3 06/22/2005 05:10:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 135 19 129 255 8.7 0 9 8.5 06/22/2005 05:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 117 255 9.2 0.2 9.6 9 06/22/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 255 255 9.6 0 9.8 9.6 06/22/2005 05:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 117 255 10.2 0.2 10.6 9.6 06/22/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 3 111 255 10.6 0 10.6 10.6 06/22/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 11.1 0.4 11.9 10.6 06/22/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 28 255 255 12.2 0.1 12.5 11.9 06/22/2005 06:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 247 15 255 255 12.8 0 12.7 12.5 06/22/2005 06:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 255 0 255 255 12.8 0 13 12.5 06/22/2005 06:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 233 27 183 255 12.5 0.1 12.7 12.5 06/22/2005 06:50:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 1.9 0.4 266 27 278 255 12.9 0.1 13.3 12.5 06/22/2005 07:00:00 1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 238 17 256 255 13.3 0.2 13.8 12.7 06/22/2005 07:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.3 1.9 0.4 267 16 305 255 13.1 0 13.5 13 06/22/2005 07:20:00 1.4 0.6 3 0.4 1.4 0.5 2.6 0.4 0.9 0.6 2.3 0.4 265 13 244 255 12.8 0 13.3 12.5 06/22/2005 07:30:00 1.4 0.5 2.3 0.4 1.4 0.6 2.3 0.4 1.1 0.6 2.3 0.4 277 23 269 255 13.3 0.2 14.1 13 06/22/2005 07:40:00 1.4 0.8 3 0.4 1.4 0.8 3 0.4 1.1 0.7 2.6 0.4 289 30 289 255 14.2 0.2 14.9 13.8 06/22/2005 07:50:00 1.7 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.4 0.7 3.8 0.4 317 27 311 255 14.3 0 14.9 14.1 06/22/2005 08:00:00 1.6 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.4 0.8 3.4 0.4 309 13 329 255 14.5 0 15.2 14.4 06/22/2005 08:10:00 1.3 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.8 0.6 3.4 0.4 241 72 274 255 14.6 0 15.2 14.6 06/22/2005 08:20:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.2 0.7 2.6 0.4 305 35 290 255 14.8 0.1 15.2 14.6 06/22/2005 08:30:00 1.6 0.9 3.4 0.4 1.6 0.9 3.8 0.4 1.3 0.8 3.4 0.4 287 45 328 255 14.6 0.1 15.2 14.4 06/22/2005 08:40:00 1.7 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.2 0.8 3.4 0.4 305 21 323 255 14.4 0 14.6 14.1 06/22/2005 08:50:00 1.5 0.8 3 0.4 1.5 0.8 3 0.4 1.2 0.7 3 0.4 301 26 246 255 14.6 0 15.2 14.6 06/22/2005 09:00:00 1.5 0.6 3 0.4 1.6 0.5 3 0.4 1.3 0.6 3 0.4 248 39 264 255 15 0 15.5 14.9 06/22/2005 09:10:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 0.9 0.6 3 0.4 269 39 314 255 15 0 15.2 14.9 06/22/2005 09:20:00 1.9 0.7 4.2 0.4 1.9 0.7 3.4 0.4 1.4 0.7 3 0.4 308 22 315 255 15 0 15.2 14.9 06/22/2005 09:30:00 1.7 0.7 3.4 0.4 1.7 0.7 3 0.4 1.4 0.7 3.4 0.4 304 19 294 255 15 0 15.5 14.9 06/22/2005 09:40:00 2.2 0.7 4.6 0.4 2.1 0.7 4.6 0.7 1.7 0.8 3.4 0.4 318 22 310 255 15.2 0.1 15.7 14.9 06/22/2005 09:50:00 1 0.8 3.4 0.4 1 0.8 3.4 0.4 0.8 0.7 3.8 0.4 235 82 316 255 15.5 0 15.7 15.2 06/22/2005 10:00:00 1.3 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 300 32 308 255 15.5 0 15.7 15.5 06/22/2005 10:10:00 1.6 0.5 3.4 0.4 1.6 0.6 3 0.4 1.2 0.5 2.6 0.4 239 29 247 255 15.9 0 16.3 15.5 06/22/2005 10:20:00 1.3 0.6 2.6 0.4 1.4 0.6 3 0.4 1 0.6 3 0.4 262 47 253 255 16.1 0 16.3 16 06/22/2005 10:30:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 271 33 308 255 15.9 0 16.3 15.7 06/22/2005 10:40:00 1.7 0.8 3.4 0.4 1.8 0.8 3.8 0.4 1.3 0.8 3.4 0.4 303 20 299 255 16.2 0 16.6 16 06/22/2005 10:50:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 1 0.5 2.6 0.4 266 35 249 255 16.1 0 16.3 16 06/22/2005 11:00:00 1.2 0.7 3 0.4 1.1 0.7 3 0.4 0.7 0.6 3 0.4 298 38 297 255 16.7 0.4 17.4 16.3 06/22/2005 11:10:00 2.2 0.8 4.2 0.4 2.2 0.8 3.8 0.4 1.8 0.9 3.8 0.4 271 26 257 255 18 0 18.2 17.4 06/22/2005 11:20:00 1.9 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.6 0.8 3.8 0.4 250 47 250 255 18 0.2 18.5 17.7 06/22/2005 11:30:00 1.2 0.8 3.8 0.4 1.2 0.8 3.8 0.4 1 0.7 3.4 0.4 288 66 281 255 17.4 0.2 18.2 17.1 06/22/2005 11:40:00 1.6 0.7 3 0.4 1.6 0.6 3.4 0.4 1.3 0.8 3.4 0.4 315 33 313 255 16.9 0.1 17.4 16.8 06/22/2005 11:50:00 1.9 0.7 4.2 0.4 2 0.7 3.8 0.7 1.5 0.7 3.4 0.4 301 21 318 255 16.7 0 17.1 16.6 06/22/2005 12:00:00 1.4 0.6 2.6 0.4 1.5 0.7 3 0.4 1.4 0.6 3 0.4 298 13 289 255 16.9 0 17.4 16.8 06/22/2005 12:10:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 304 22 286 255 17.2 0.1 17.7 16.8 06/22/2005 12:20:00 0.9 0.6 3 0.4 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 282 72 306 255 17.6 0 18 17.4 06/22/2005 12:30:00 0.7 0.6 2.3 0.4 0.8 0.6 1.9 0.4 0.7 0.5 1.9 0.4 51 98 268 255 17.8 0 18.2 17.4 06/22/2005 12:40:00 1.6 0.8 3.8 0.4 1.6 0.8 3.4 0.4 1.3 0.7 3.4 0.4 291 30 306 255 18 0.1 18.5 17.7 06/22/2005 12:50:00 2.4 0.8 3.8 0.4 2.4 0.7 3.8 0.7 1.9 0.8 3.8 0.4 297 24 318 255 17.9 0 18.5 17.7 06/22/2005 13:00:00 3.5 0.8 5.3 1.5 3.5 0.9 4.9 1.1 3 1 5.3 0.7 306 17 294 255 17.6 0.2 18.2 17.1 06/22/2005 13:10:00 3.5 0.8 4.9 1.1 3.5 0.8 4.9 1.1 2.9 1 4.9 0.4 303 16 327 255 17.1 0.2 17.7 16.8 06/22/2005 13:20:00 2.9 0.6 4.2 1.5 2.9 0.6 4.2 1.5 2.4 0.8 4.2 0.7 300 16 295 255 17 0.1 17.7 16.8 06/22/2005 13:30:00 2.3 0.5 3.8 0.7 2.3 0.5 3.8 0.7 1.9 0.7 3.4 0.4 302 21 301 255 17.6 0.1 18.2 17.1 06/22/2005 13:40:00 2 0.6 3.4 0.4 2 0.6 3.4 0.4 1.6 0.7 3.4 0.4 320 18 317 255 17.9 0.1 18.5 17.7 06/22/2005 13:50:00 1.4 0.8 3 0.4 1.4 0.8 3 0.4 1.1 0.8 3 0.4 314 56 334 255 18.4 0.1 19.1 18.2 06/22/2005 14:00:00 2.6 0.5 4.2 1.1 2.7 0.5 4.2 1.1 2.1 0.8 3.8 0.4 305 16 282 255 18.3 0.2 19.1 18 06/22/2005 14:10:00 3 1 4.9 0.4 3.1 1 4.9 0.4 2.8 1 4.6 0.4 296 20 315 255 18.4 0.1 18.8 18 06/22/2005 14:20:00 2.5 1 4.9 0.4 2.6 1 4.9 0.4 2.2 1 4.6 0.4 279 19 300 255 18.6 0.1 19.1 18.2 06/22/2005 14:30:00 1.6 0.8 3 0.4 1.7 0.8 3 0.4 1.4 0.7 3 0.4 262 56 256 255 19 0 19.4 18.8 06/22/2005 14:40:00 2 1.1 4.2 0.4 2 1.1 4.2 0.4 1.6 1 4.6 0.4 328 39 315 255 18.9 0.2 19.4 18.5 06/22/2005 14:50:00 2 0.6 3.8 0.4 2.1 0.6 3.8 0.4 1.7 0.6 3.4 0.4 289 26 294 255 18.7 0.1 19.1 18.5 06/22/2005 15:00:00 2.7 0.8 4.9 0.7 2.7 0.8 4.9 0.7 2.3 0.8 4.2 0.4 299 18 287 255 18.7 0.2 19.4 18.2 06/22/2005 15:10:00 3.2 0.7 4.9 1.1 3.1 0.7 4.9 1.1 2.7 0.8 5.7 0.7 299 22 267 255 18.8 0.2 19.4 18.2 06/22/2005 15:20:00 3.4 1 6.1 0.7 3.3 1 6.1 0.7 2.5 1 4.6 0.4 301 23 329 255 18.9 0.3 19.4 18.2 06/22/2005 15:30:00 4 1.1 6.5 1.1 3.9 1.1 6.5 1.1 3.2 1.2 6.1 0.4 301 16 294 255 18.2 0.3 19.1 17.7 06/22/2005 15:40:00 4.3 0.7 6.1 2.6 4.2 0.8 6.1 2.3 3.2 1 6.1 1.1 309 13 296 255 17.8 0.2 18.2 17.1 06/22/2005 15:50:00 4.4 0.9 6.5 1.9 4.3 0.9 6.5 1.9 3.5 0.9 5.7 1.1 305 14 322 255 16.9 0.3 17.4 16.3 06/22/2005 16:00:00 3.6 0.9 5.7 1.5 3.4 0.9 5.7 1.9 2.6 0.9 4.9 0.4 312 16 322 255 16.1 0.1 16.8 16 06/22/2005 16:10:00 1.7 0.7 3.8 0.4 1.7 0.7 3.4 0.4 1.2 0.7 3 0.4 307 28 272 255 15.9 0 16.6 16 06/22/2005 16:20:00 2.5 0.8 4.6 0.7 2.5 0.8 4.6 0.7 1.6 0.9 4.2 0.4 323 21 298 255 15.9 0 16.6 15.7 06/22/2005 16:30:00 2.6 0.7 4.6 1.1 2.5 0.7 4.6 0.7 1.7 0.9 4.2 0.4 325 18 313 255 15.6 0 16 15.7 06/22/2005 16:40:00 1.9 0.6 3.8 0.4 1.9 0.6 3.4 0.4 1.2 0.7 3.4 0.4 307 22 317 255 15.6 0 15.7 15.5 06/22/2005 16:50:00 1.4 0.7 3.4 0.4 1.4 0.8 3.4 0.4 1 0.6 2.6 0.4 288 26 255 255 16 0 16.3 15.7 06/22/2005 17:00:00 1.8 0.7 3.4 0.4 1.8 0.8 3.8 0.4 1.6 0.7 3 0.4 283 27 258 255 16.4 0 16.6 16.3 06/22/2005 17:10:00 2 0.5 3.4 1.1 2 0.5 3.4 0.7 1.6 0.6 3 0.4 311 9 304 255 16.4 0 16.8 16.3 06/22/2005 17:20:00 1.1 0.6 3 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.6 0.4 312 20 286 255 16.4 0 16.8 16.3 06/22/2005 17:30:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 327 47 283 255 16.9 0 17.1 16.8 06/22/2005 17:40:00 0.6 0.4 2.3 0.4 0.7 0.5 2.6 0.4 0.5 0.3 1.9 0.4 148 30 235 255 17.1 0 17.4 16.8 06/22/2005 17:50:00 1.2 0.8 3 0.4 1.2 0.9 3 0.4 1.1 0.8 3 0.4 191 24 219 255 17.3 0 17.4 17.1 06/22/2005 18:00:00 1.3 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1 0.6 3 0.4 209 43 246 255 17.4 0 17.7 17.1 06/22/2005 18:10:00 1.3 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1 0.7 3 0.4 58 66 58 255 17.3 0 17.4 17.1 06/22/2005 18:20:00 1.3 1.1 4.6 0.4 1.3 1.1 4.6 0.4 0.9 0.9 4.2 0.4 46 69 61 255 17.3 0 17.4 17.1 06/22/2005 18:30:00 2.1 0.6 3.4 0.7 2.2 0.6 3.4 0.7 1.5 0.5 3 0.4 59 24 35 255 17 0 17.1 16.8 06/22/2005 18:40:00 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 84 19 84 255 16.6 0 16.8 16.6 06/22/2005 18:50:00 1.6 0.8 3 0.4 1.6 0.8 3 0.4 1.3 0.8 3 0.4 63 23 51 255 16.4 0 16.8 16.3 06/22/2005 19:00:00 1.6 0.5 3 0.4 1.7 0.6 3.4 0.4 1.1 0.6 2.6 0.4 12 29 0 255 16.3 0 16.6 16.3 06/22/2005 19:10:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.6 2.3 0.4 337 28 307 255 16.3 0 16.6 16.3 06/22/2005 19:20:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.9 0.6 2.6 0.4 332 19 298 255 16.1 0 16.6 16 06/22/2005 19:30:00 2.7 0.6 4.2 1.1 2.3 0.5 3.8 0.7 2.1 0.7 3.4 0.4 335 11 332 255 15.9 0.1 16.3 15.7 06/22/2005 19:40:00 1.8 0.8 3.8 0.4 1.7 0.8 3 0.4 0.9 0.7 2.6 0.4 352 15 312 255 15.6 0 16 15.5 06/22/2005 19:50:00 2 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.5 0.7 3 0.4 335 9 341 255 15.5 0 16 15.5 06/22/2005 20:00:00 2 0.5 3.4 0.7 1.9 0.6 3 0.7 1.4 0.7 3 0.4 305 17 291 255 15.3 0 15.7 15.2 06/22/2005 20:10:00 1.5 0.6 3 0.4 1.5 0.7 3 0.4 1 0.6 2.6 0.4 293 19 293 255 15.1 0 15.5 15.2 06/22/2005 20:20:00 1.5 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1 0.6 2.3 0.4 310 11 287 255 14.9 0 15.5 14.6 06/22/2005 20:30:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 322 6 317 255 14.7 0.1 15.2 14.6 06/22/2005 20:40:00 1.6 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.9 0.4 2.3 0.4 310 7 317 255 14.6 0 15.2 14.4 06/22/2005 20:50:00 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 303 26 292 255 14.4 0.2 14.9 14.1 06/22/2005 21:00:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.6 0.4 1.9 0.4 13 17 355 255 14.1 0.2 14.6 13.8 06/22/2005 21:10:00 1.2 0.5 1.9 0.4 1.2 0.5 2.3 0.4 0.4 0.2 1.5 0.4 25 20 12 255 13.9 0 14.4 13.5 06/22/2005 21:20:00 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0 0.4 0.4 50 26 3 255 13.5 0 13.8 13.3 06/22/2005 21:30:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.8 0.5 2.3 0.4 55 12 62 255 13.4 0 13.8 13.3 06/22/2005 21:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 74 15 74 255 13.3 0 13.5 13 06/22/2005 21:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 70 6 73 255 13 0.1 13.5 12.7 06/22/2005 22:00:00 1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 81 4 83 255 12.8 0 13.3 12.7 06/22/2005 22:10:00 2 0.4 2.6 1.1 2 0.4 2.6 1.1 1.1 0.4 2.3 0.4 78 4 77 255 12.6 0 13 12.5 06/22/2005 22:20:00 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 0.8 0.4 1.9 0.4 76 7 75 255 12.3 0 12.7 12.2 06/22/2005 22:30:00 1.7 0.3 2.3 0.7 1.7 0.3 2.6 0.7 0.8 0.4 1.9 0.4 79 8 80 255 11.9 0 12.2 11.7 06/22/2005 22:40:00 1.5 0.4 2.3 0.7 1.4 0.4 2.6 0.7 0.8 0.4 1.9 0.4 92 15 93 255 11.7 0 12.2 11.7 06/22/2005 22:50:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 0.9 0.5 2.3 0.4 107 13 74 255 11.7 0 11.9 11.7 06/22/2005 23:00:00 2 0.4 2.6 1.1 2 0.4 2.6 1.1 1.1 0.4 1.9 0.4 98 8 106 255 11.5 0 11.9 11.4 06/22/2005 23:10:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.5 1.4 0.5 2.6 0.4 88 7 80 255 11.4 0 11.7 11.4 06/22/2005 23:20:00 2 0.5 3 0.7 1.9 0.5 3.4 0.4 0.8 0.5 1.9 0.4 95 12 97 255 11.4 0 11.7 11.4 06/22/2005 23:30:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 0.9 0.5 2.3 0.4 122 12 100 255 11.1 0 11.4 10.9 06/22/2005 23:40:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 1.4 0.5 2.3 0.4 116 11 103 255 10.9 0 11.1 10.9 06/22/2005 23:50:00 2.1 0.4 3 1.1 2.1 0.3 3 1.5 1.1 0.5 2.3 0.4 95 9 121 255 11.1 0 11.4 11.1 06/23/2005 00:00:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 0.8 0.4 1.9 0.4 88 7 92 255 11 0 11.7 10.9 06/23/2005 00:10:00 1.6 0.3 2.6 0.7 1.6 0.3 2.3 0.7 0.6 0.3 1.5 0.4 106 14 121 255 10.7 0 10.9 10.6 06/23/2005 00:20:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.6 0.3 1.9 0.4 118 12 116 255 10.6 0 10.6 10.6 06/23/2005 00:30:00 1.4 0.4 2.3 0.4 1.4 0.4 2.6 0.4 0.8 0.3 1.5 0.4 101 8 108 255 10.6 0 10.9 10.6 06/23/2005 00:40:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.6 0.4 1.9 0.4 90 27 78 255 10.6 0 10.6 10.6 06/23/2005 00:50:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 108 2 107 255 10.6 0 10.6 10.6 06/23/2005 01:00:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 120 15 123 255 10.5 0 10.6 10.3 06/23/2005 01:10:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.8 0.4 1.9 0.4 117 11 131 255 10.4 0 10.6 10.3 06/23/2005 01:20:00 1.7 0.5 2.6 0.4 1.7 0.4 2.6 0.4 0.8 0.5 2.3 0.4 101 16 92 255 10.2 0 10.3 10.3 06/23/2005 01:30:00 1.5 0.4 2.6 0.4 1.5 0.5 2.6 0.4 0.8 0.4 1.9 0.4 120 15 106 255 10.3 0 10.3 10.3 06/23/2005 01:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0.4 0.2 1.1 0.4 137 8 99 255 10.2 0 10.3 10.1 06/23/2005 01:50:00 1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 138 6 141 255 10.2 0 10.3 10.1 06/23/2005 02:00:00 1.5 0.5 2.6 0.4 1.4 0.4 2.6 0.4 0.7 0.3 1.9 0.4 105 17 104 255 10.2 0 10.3 10.1 06/23/2005 02:10:00 2.1 0.4 3.4 1.5 2.1 0.4 3.4 1.1 1.3 0.5 2.6 0.4 90 8 80 255 10.2 0 10.3 10.3 06/23/2005 02:20:00 2.6 0.5 3.8 1.5 2.6 0.5 4.2 1.5 1.7 0.6 3.4 0.7 73 12 72 255 10.3 0 10.6 10.3 06/23/2005 02:30:00 2.7 0.5 4.2 1.5 2.7 0.6 4.2 1.5 1.9 0.6 3.4 0.4 64 11 63 255 10.5 0 10.6 10.3 06/23/2005 02:40:00 2.5 0.7 4.2 0.7 2.5 0.7 4.2 0.7 1.8 0.8 4.2 0.4 67 15 56 255 10.7 0 10.9 10.6 06/23/2005 02:50:00 2.1 0.6 3.4 0.7 2 0.6 3.4 0.7 1.2 0.6 2.3 0.4 59 14 84 255 10.9 0 11.1 10.9 06/23/2005 03:00:00 1.8 0.5 3 0.4 1.8 0.6 3 0.4 1.1 0.5 2.6 0.4 58 12 63 255 11 0 11.1 10.9 06/23/2005 03:10:00 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.7 0.9 0.4 2.3 0.4 63 7 62 255 10.8 0 10.9 10.6 06/23/2005 03:20:00 2 0.4 3 1.1 1.9 0.4 3 1.1 0.8 0.4 2.3 0.4 80 8 81 255 10.5 0 10.6 10.3 06/23/2005 03:30:00 2.4 0.5 4.2 1.5 2.3 0.5 4.2 1.1 1.3 0.5 2.6 0.4 90 9 86 255 10.3 0 10.6 10.3 06/23/2005 03:40:00 1.5 0.6 3 0.4 1.4 0.7 2.6 0.4 0.6 0.3 1.9 0.4 76 12 82 255 10.5 0 10.6 10.3 06/23/2005 03:50:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 63 0 63 255 10.2 0 10.6 10.1 06/23/2005 04:00:00 1 0.3 1.9 0.4 0.8 0.4 2.3 0.4 0.4 0.2 1.1 0.4 62 1 62 255 10.1 0 10.3 10.1 06/23/2005 04:10:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 59 7 35 255 10.1 0 10.3 10.1 06/23/2005 04:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 62 0 62 255 10.2 0 10.3 10.1 06/23/2005 04:30:00 1 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 63 2 62 255 10.2 0 10.3 10.3 06/23/2005 04:40:00 1.2 0.3 2.3 0.4 1.1 0.3 1.9 0.4 0.4 0 0.7 0.4 78 7 76 255 10.3 0 10.6 10.3 06/23/2005 04:50:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 105 20 76 255 10.3 0 10.6 10.3 06/23/2005 05:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 97 17 93 255 10.5 0 10.6 10.6 06/23/2005 05:10:00 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 88 0 89 255 10.7 0.1 10.9 10.6 06/23/2005 05:20:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 89 6 80 255 11 0 11.1 10.9 06/23/2005 05:30:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 95 9 109 255 11.3 0 11.7 11.1 06/23/2005 05:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 70 5 66 255 11.7 0 11.7 11.7 06/23/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 255 255 11.7 0 11.9 11.7 06/23/2005 06:00:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 69 0 69 255 11.9 0 11.9 11.9 06/23/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 255 255 12 0 12.2 11.9 06/23/2005 06:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.5 0.4 0.4 0 0.4 0.4 69 0 69 255 12.1 0 12.2 11.9 06/23/2005 06:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 69 0 69 255 12.1 0 12.2 11.9 06/23/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 255 255 12 0 12.2 11.9 06/23/2005 06:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 52 15 32 255 12.1 0 12.2 11.9 06/23/2005 07:00:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 41 9 37 255 12.2 0 12.7 11.9 06/23/2005 07:10:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 39 15 14 255 12.5 0 12.7 12.2 06/23/2005 07:20:00 1.4 0.4 3 0.4 1.3 0.4 2.6 0.4 0.6 0.4 1.9 0.4 21 12 4 255 12.7 0 13.3 12.5 06/23/2005 07:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 25 15 22 255 12.9 0 13.3 12.7 06/23/2005 07:40:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 40 9 58 255 13 0.1 13.5 12.7 06/23/2005 07:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 57 0 58 255 13.4 0 13.8 13.3 06/23/2005 08:00:00 0.7 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 66 24 29 255 13.6 0.1 14.1 13.3 06/23/2005 08:10:00 0.6 0.4 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 46 20 25 255 14 0.1 14.4 13.8 06/23/2005 08:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 24 15 51 255 14.3 0 14.6 14.1 06/23/2005 08:30:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 348 20 354 255 14.8 0.2 15.7 14.6 06/23/2005 08:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 344 26 14 255 15.5 0.3 16.3 15.2 06/23/2005 08:50:00 1.8 0.6 3.4 0.7 1.8 0.6 3.4 0.7 1.6 0.7 3.4 0.4 303 22 282 255 16.4 0.3 17.1 16 06/23/2005 09:00:00 1.6 1 3.4 0.4 1.6 0.9 3.4 0.4 1.3 0.8 3.4 0.4 274 39 301 255 15.9 0 16.6 15.7 06/23/2005 09:10:00 1.8 0.5 3 0.7 1.7 0.5 3 0.7 1.4 0.6 3 0.4 316 22 307 255 15.9 0.1 16.3 15.7 06/23/2005 09:20:00 2.2 0.5 3.4 0.4 2.2 0.5 3.4 0.4 1.9 0.6 3.4 0.4 301 20 290 255 15.9 0.1 16.3 15.7 06/23/2005 09:30:00 1.8 0.6 3 0.4 1.9 0.5 3 0.7 1.8 0.6 3 0.4 307 32 286 255 15.9 0.1 16.3 15.7 06/23/2005 09:40:00 1.7 0.8 3.8 0.4 1.6 0.8 3.4 0.4 1.3 0.8 3.4 0.4 317 29 340 255 16.3 0 16.8 16.3 06/23/2005 09:50:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.5 0.6 3 0.4 314 41 294 255 17.2 0.2 17.4 16.8 06/23/2005 10:00:00 1.4 0.5 2.6 0.4 1.5 0.5 3 0.4 1.3 0.6 2.6 0.4 275 17 296 255 16.9 0.1 17.4 16.8 06/23/2005 10:10:00 1.5 0.7 3 0.4 1.5 0.7 2.6 0.4 1.4 0.8 3.4 0.4 309 33 271 255 17.1 0 17.4 16.8 06/23/2005 10:20:00 1.2 0.8 2.6 0.4 1.2 0.7 2.6 0.4 1 0.8 3 0.4 319 26 321 255 16.9 0 17.4 16.8 06/23/2005 10:30:00 1.3 0.7 2.6 0.4 1.2 0.7 3 0.4 1.2 0.7 3.4 0.4 333 35 320 255 17 0.1 17.7 16.8 06/23/2005 10:40:00 1.3 0.6 2.6 0.4 1.3 0.6 3 0.4 1.2 0.6 3 0.4 311 35 319 255 17.5 0 18.2 17.4 06/23/2005 10:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 52 79 328 255 17.8 0.1 18.2 17.4 06/23/2005 11:00:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 311 76 334 255 18.2 0.1 18.8 18 06/23/2005 11:10:00 2.1 0.5 3.8 0.4 2 0.5 3.8 0.4 1.6 0.6 3 0.4 5 22 46 255 18.7 0.1 19.1 18.5 06/23/2005 11:20:00 2.2 0.5 3.4 0.7 2.3 0.5 3.4 1.1 2 0.5 3.4 1.1 27 16 21 255 18.3 0.2 19.1 18 06/23/2005 11:30:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 1.3 0.5 2.3 0.4 59 22 80 255 18.2 0 18.5 18 06/23/2005 11:40:00 2.4 0.6 3.8 0.4 2.4 0.6 3.8 0.4 1.9 0.7 3.4 0.4 24 32 23 255 18.5 0.1 18.8 18.2 06/23/2005 11:50:00 2 0.5 3.4 0.7 2.1 0.5 3.4 1.1 1.8 0.5 3 0.7 38 12 33 255 18.4 0 18.8 18.2 06/23/2005 12:00:00 1.8 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.6 0.8 3.4 0.4 33 29 35 255 18.4 0.2 19.1 18 06/23/2005 12:10:00 1.9 0.5 3.4 0.4 1.9 0.6 3.4 0.4 1.5 0.6 2.6 0.4 357 23 2 255 18.7 0 19.4 18.5 06/23/2005 12:20:00 1.1 0.7 2.6 0.4 1 0.7 2.6 0.4 1 0.7 3 0.4 299 32 291 255 18.8 0 19.4 18.5 06/23/2005 12:30:00 0.8 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.8 0.5 2.3 0.4 302 32 253 255 18.6 0.1 19.1 18.5 06/23/2005 12:40:00 1.4 0.6 3 0.4 1.5 0.6 2.6 0.4 1.4 0.7 3 0.4 269 26 299 255 18.6 0.2 19.1 18.2 06/23/2005 12:50:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.4 2.3 0.4 230 33 238 255 18.6 0.1 19.1 18.5 06/23/2005 13:00:00 1.8 0.8 4.2 0.4 1.9 0.8 4.6 0.4 1.6 0.8 4.2 0.4 257 35 266 255 19 0 19.4 18.5 06/23/2005 13:10:00 2.3 1.1 4.9 0.4 2.3 1.1 4.6 0.4 1.9 1.1 4.6 0.4 286 28 291 255 19 0.2 19.4 18.5 06/23/2005 13:20:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 1.6 0.6 3 0.4 233 24 255 255 19.4 0.1 20 19.1 06/23/2005 13:30:00 1.7 0.8 3.4 0.4 1.8 0.8 3.4 0.4 1.6 0.7 3 0.4 264 12 252 255 19.3 0.1 20 19.1 06/23/2005 13:40:00 1.6 1 4.6 0.4 1.6 1.1 4.2 0.4 1.4 1.1 4.9 0.4 307 58 287 255 19.5 0.1 20 19.4 06/23/2005 13:50:00 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.6 0.5 2.3 0.4 217 66 283 255 20 0.4 20.8 19.4 06/23/2005 14:00:00 1.9 0.6 3.8 0.4 1.9 0.7 3.4 0.4 1.5 0.8 3.4 0.4 276 29 310 255 20 0.2 20.8 19.4 06/23/2005 14:10:00 1.5 1.1 3.8 0.4 1.5 1.1 3.8 0.4 1.2 1 3.8 0.4 259 64 212 255 19.7 0 20.3 19.4 06/23/2005 14:20:00 2.1 0.8 4.9 0.7 2.1 0.8 4.9 0.7 1.8 0.7 3.8 0.4 279 27 268 255 19.9 0 20.3 19.7 06/23/2005 14:30:00 1.8 1 3.8 0.4 1.8 1 4.2 0.4 1.5 0.9 3.8 0.4 265 45 228 255 20 0 20.3 19.7 06/23/2005 14:40:00 2 0.8 4.2 0.4 2.1 0.7 4.2 0.4 1.8 0.8 4.2 0.4 264 35 286 255 19.6 0.1 20 19.4 06/23/2005 14:50:00 2.9 0.8 4.9 0.7 2.9 0.8 4.9 1.1 2.4 1 5.3 0.4 293 22 293 255 19.8 0.1 20.5 19.4 06/23/2005 15:00:00 2.5 1 4.9 0.7 2.4 1 4.9 0.7 2 1.2 4.9 0.4 307 22 295 255 19.5 0 20 19.1 06/23/2005 15:10:00 2.8 0.8 4.6 0.7 2.7 0.9 4.9 0.7 2.3 1 4.6 0.4 311 23 295 255 19.5 0.1 20 19.4 06/23/2005 15:20:00 3 1 4.9 0.4 3 1 4.9 0.4 2.5 1.1 4.9 0.4 300 22 296 255 19.3 0 20 19.1 06/23/2005 15:30:00 2 0.8 3.8 0.4 2.1 0.8 3.8 0.4 1.5 0.8 3.8 0.4 270 29 248 255 19.3 0 20 19.1 06/23/2005 15:40:00 2 0.9 4.2 0.4 2.1 0.9 4.2 0.7 1.7 0.9 3.8 0.4 291 26 305 255 19.4 0 20 19.1 06/23/2005 15:50:00 2.7 1.2 5.3 0.4 2.7 1.2 4.9 0.4 2.3 1.2 4.6 0.4 308 18 295 255 19.5 0.1 20.3 19.1 06/23/2005 16:00:00 3.3 0.8 4.9 1.5 3.2 0.8 5.3 1.1 2.6 1 4.9 0.7 314 20 296 255 20.4 0.5 21.7 19.7 06/23/2005 16:10:00 2.9 0.9 5.3 0.4 2.8 0.9 5.3 0.4 2.2 1 4.9 0.4 304 30 311 255 21.3 0.2 22 20.8 06/23/2005 16:20:00 3.7 1 5.7 1.5 3.5 0.9 5.3 1.5 2.9 1.1 5.7 1.1 317 18 352 255 21.3 0 21.7 21.1 06/23/2005 16:30:00 3.8 1 6.5 1.9 3.7 1 6.1 1.5 3.1 1.2 5.7 0.4 307 24 301 255 21.5 0.4 22 20.5 06/23/2005 16:40:00 3.5 0.9 5.7 1.1 3.4 0.9 5.7 1.1 2.8 1 4.9 1.1 292 18 291 255 19.9 0.2 20.5 19.4 06/23/2005 16:50:00 3.8 0.8 5.7 1.1 3.8 0.8 5.7 1.5 3.1 1.1 5.7 0.4 296 14 289 255 19.7 0 20 19.4 06/23/2005 17:00:00 3.6 0.6 5.3 1.9 3.6 0.6 5.3 2.3 3 0.8 5.3 1.1 292 16 286 255 19.6 0.2 20 19.1 06/23/2005 17:10:00 3.2 0.8 5.7 1.1 3.2 0.8 5.3 0.7 2.3 0.8 4.6 0.7 300 21 270 255 19.3 0.2 20 18.8 06/23/2005 17:20:00 3.3 0.8 5.7 1.5 3.3 0.8 4.9 1.5 2.5 1.1 4.9 0.4 293 22 286 255 20.2 0.1 20.5 19.7 06/23/2005 17:30:00 2.9 1.1 5.7 0.4 2.9 1.1 5.7 0.4 2.3 1.2 5.3 0.4 300 20 301 255 20.1 0.1 20.5 20 06/23/2005 17:40:00 3.7 0.9 6.1 1.9 3.6 0.9 6.1 1.5 2.9 1 5.3 0.7 304 19 322 255 20.3 0 20.5 20 06/23/2005 17:50:00 3.6 0.9 6.1 1.5 3.5 1 6.1 1.1 2.9 1.2 6.1 0.4 301 19 291 255 20.1 0 20.5 20 06/23/2005 18:00:00 3.8 1 6.1 1.1 3.7 1 6.5 1.1 3 1.2 6.1 0.4 311 17 296 255 20.3 0.1 21.1 20.3 06/23/2005 18:10:00 4 1 6.5 1.9 3.9 1 6.8 1.9 3.2 1 6.5 1.1 296 17 282 255 20.3 0 20.5 20.3 06/23/2005 18:20:00 3.8 0.9 6.1 1.5 3.7 1 6.1 1.1 3.1 1.2 5.7 0.4 298 20 289 255 20 0 20.5 19.7 06/23/2005 18:30:00 3.5 1.2 6.8 0.7 3.5 1.1 6.5 0.7 2.7 1.2 6.1 0.7 299 19 300 255 19.5 0.1 20 19.4 06/23/2005 18:40:00 2.5 0.8 4.6 0.7 2.5 0.7 4.2 0.7 1.8 0.7 3.8 0.4 301 19 287 255 19.3 0 20 19.1 06/23/2005 18:50:00 2.5 0.8 4.6 1.1 2.4 0.8 4.6 0.4 1.8 0.8 3.4 0.4 294 16 293 255 19 0 19.4 18.8 06/23/2005 19:00:00 2.5 0.8 5.3 0.7 2.5 0.8 4.9 0.4 1.9 0.9 4.2 0.4 294 20 291 255 18.9 0 19.4 18.8 06/23/2005 19:10:00 3 0.8 5.3 1.1 3 0.7 4.9 1.5 2.4 1 4.6 0.4 292 18 282 255 18.9 0 19.4 18.8 06/23/2005 19:20:00 2.9 0.9 5.7 1.1 2.9 0.9 5.7 1.1 2.1 0.9 5.3 0.4 290 20 269 255 18.9 0 19.4 18.8 06/23/2005 19:30:00 2.8 1 5.3 0.4 2.8 1 5.3 0.4 2 1 4.9 0.4 295 17 277 255 19 0 19.4 18.8 06/23/2005 19:40:00 3.7 0.9 6.1 1.5 3.7 0.9 6.1 1.1 2.9 1 5.7 0.4 277 18 280 255 19.2 0 19.7 19.1 06/23/2005 19:50:00 2.9 1.1 5.3 0.7 2.9 1 5.7 0.7 2.2 1 4.2 0.4 254 24 252 255 19.1 0.1 19.7 18.8 06/23/2005 20:00:00 2.9 1 6.1 0.7 3 1.1 6.1 0.4 2.3 1.2 6.1 0.4 262 22 255 255 18.8 0 19.1 18.5 06/23/2005 20:10:00 2.5 1 4.9 0.4 2.6 1 4.9 0.4 1.7 0.9 3.8 0.4 260 21 257 255 18.6 0 18.8 18.5 06/23/2005 20:20:00 2.7 1 5.3 0.4 2.8 0.9 5.3 1.1 2 1 5.7 0.4 254 18 251 255 18.3 0 18.5 18.2 06/23/2005 20:30:00 3.1 1.2 6.8 0.4 3.2 1.1 6.8 0.7 2.2 1.2 6.1 0.4 253 21 250 255 18.1 0 18.2 18 06/23/2005 20:40:00 2.6 0.8 4.6 0.7 2.7 0.8 4.6 1.1 1.8 0.9 4.2 0.4 249 19 286 255 17.8 0 18 17.4 06/23/2005 20:50:00 2.5 0.9 6.1 1.1 2.5 0.9 6.1 1.1 1.8 0.9 4.6 0.4 255 22 270 255 17.3 0.1 17.7 17.1 06/23/2005 21:00:00 3.2 0.8 6.1 1.5 3.2 0.8 6.1 1.5 2.3 0.9 6.1 0.4 259 18 255 255 17.1 0 17.4 16.8 06/23/2005 21:10:00 2.5 1.1 5.3 0.4 2.6 1 5.3 0.4 1.7 1 4.2 0.4 262 17 279 255 16.7 0 17.1 16.6 06/23/2005 21:20:00 2.9 1 5.3 0.7 3 1 5.7 0.7 2.1 1 4.9 0.4 262 19 253 255 16.5 0.1 16.8 16.3 06/23/2005 21:30:00 2.2 0.9 4.9 0.4 2.3 0.9 4.6 0.4 1.2 0.8 3.8 0.4 262 21 268 255 16.2 0.1 16.8 16 06/23/2005 21:40:00 1.6 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.1 0.7 3.4 0.4 265 15 263 255 15.7 0.1 16.3 15.5 06/23/2005 21:50:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.3 0.8 3.4 0.4 257 18 255 255 15.2 0.1 15.7 14.9 06/23/2005 22:00:00 1.9 0.8 3.8 0.4 2 0.8 3.8 0.4 0.9 0.8 3.4 0.4 255 17 253 255 14.6 0.1 15.5 14.4 06/23/2005 22:10:00 1.6 0.6 3.4 0.4 1.7 0.6 3.4 0.4 0.8 0.5 2.3 0.4 256 17 268 255 14.1 0.1 14.9 13.8 06/23/2005 22:20:00 1.9 0.6 3.8 0.7 2 0.6 3.8 0.7 1.1 0.6 2.6 0.4 246 12 256 255 13.8 0.1 14.4 13.3 06/23/2005 22:30:00 2.1 0.6 3.8 0.7 2.1 0.5 3.8 0.7 1.1 0.7 3 0.4 244 13 252 255 13.6 0.1 13.8 13.3 06/23/2005 22:40:00 1.9 0.6 3.8 0.7 2 0.6 3.8 0.7 1 0.6 3 0.4 246 15 245 255 13.5 0.1 14.1 13.3 06/23/2005 22:50:00 2.2 0.7 3.8 0.4 2.2 0.7 4.2 0.4 1.3 0.7 3.4 0.4 242 13 244 255 13.6 0 14.4 13.5 06/23/2005 23:00:00 2.3 0.7 3.8 1.1 2.4 0.6 4.2 1.1 1.5 0.6 3.4 0.4 227 15 252 255 13.5 0 13.5 13.3 06/23/2005 23:10:00 1.7 0.5 3 0.4 1.8 0.5 3.8 0.7 0.8 0.5 2.3 0.4 221 17 237 255 13.3 0 13.5 13.3 06/23/2005 23:20:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 0.6 0.4 2.3 0.4 230 28 236 255 13.3 0 13.3 13 06/23/2005 23:30:00 1.4 0.9 3.4 0.4 1.4 0.9 3.8 0.4 0.9 0.7 3.4 0.4 262 13 253 255 13.3 0 13.3 13 06/23/2005 23:40:00 1.5 0.6 3.4 0.4 1.5 0.6 3.4 0.4 0.7 0.4 1.9 0.4 261 17 275 255 13 0.1 13.3 12.7 06/23/2005 23:50:00 1.6 0.8 3.8 0.4 1.6 0.8 3.8 0.4 0.9 0.7 3.4 0.4 252 11 255 255 12.8 0 13.3 12.7 06/24/2005 00:00:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 0.7 0.5 2.6 0.4 261 13 267 255 12.7 0 13 12.5 06/24/2005 00:10:00 1.4 0.6 3 0.4 1.4 0.7 3.4 0.4 0.8 0.5 2.6 0.4 260 13 253 255 12.6 0 13 12.5 06/24/2005 00:20:00 2.2 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.5 0.8 3.8 0.4 246 17 263 255 12.7 0 13.3 12.5 06/24/2005 00:30:00 2.6 0.7 4.6 0.4 2.7 0.7 4.9 0.7 1.6 0.7 4.2 0.4 247 19 229 255 12.9 0.1 13.3 12.7 06/24/2005 00:40:00 2 0.6 3.4 0.4 2 0.6 3.4 0.7 1 0.6 3 0.4 244 18 251 255 13.1 0 13.5 13 06/24/2005 00:50:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.5 0.3 2.3 0.4 261 20 243 255 13.1 0 13.5 13 06/24/2005 01:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 216 21 220 255 12.9 0 13.3 12.7 06/24/2005 01:10:00 1.1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.6 0.3 1.5 0.4 186 9 170 255 12.7 0 13 12.5 06/24/2005 01:20:00 0.9 0.4 1.9 0.4 0.9 0.4 2.3 0.4 0.4 0.2 1.5 0.4 195 4 187 255 12.3 0 12.7 12.2 06/24/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 12.1 0.2 12.7 11.7 06/24/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.7 0 12.2 11.4 06/24/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.3 0 11.7 11.1 06/24/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.1 0 11.7 11.1 06/24/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.1 0 11.7 11.1 06/24/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.1 0 11.4 11.1 06/24/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.2 0 11.7 11.1 06/24/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.3 0 11.4 11.1 06/24/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.3 0 11.7 11.4 06/24/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 255 255 11.3 0 11.4 11.4 06/24/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 196 0 255 255 11.4 0 11.7 11.4 06/24/2005 03:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 196 0 196 255 11.5 0 11.7 11.4 06/24/2005 03:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 196 0 196 255 11.5 0 11.7 11.4 06/24/2005 03:40:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 196 0 196 255 11.5 0 11.7 11.4 06/24/2005 03:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 196 0 196 255 11.5 0 11.7 11.4 06/24/2005 04:00:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.5 0.4 196 0 196 255 11.5 0 11.7 11.4 06/24/2005 04:10:00 0.7 0.3 1.1 0.4 0.9 0.2 1.5 0.4 0.6 0.3 1.5 0.4 183 6 196 255 11.7 0 11.7 11.7 06/24/2005 04:20:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.3 0.4 1.9 0.4 154 10 147 255 11.7 0 11.7 11.7 06/24/2005 04:30:00 1.2 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.6 0.4 1.9 0.4 136 4 140 255 11.7 0 11.7 11.7 06/24/2005 04:40:00 0.9 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 133 0 133 255 11.7 0 11.7 11.7 06/24/2005 04:50:00 0.9 0.3 1.5 0.4 1.1 0.6 1.9 0.4 1.1 0.4 1.9 0.4 159 15 174 255 11.5 0 11.7 11.4 06/24/2005 05:00:00 1.3 0.3 2.3 0.7 1.9 0.3 2.3 0.7 0.9 0.4 1.9 0.4 171 5 165 255 11.7 0 11.7 11.7 06/24/2005 05:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 0.7 0.4 165 0 165 255 11.9 0.1 12.2 11.7 06/24/2005 05:20:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 131 16 164 255 12.3 0 12.5 11.9 06/24/2005 05:30:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 70 16 80 255 12.3 0 12.5 12.2 06/24/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 0 255 255 12.4 0 12.7 12.2 06/24/2005 05:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 74 6 79 255 12.4 0 12.7 12.2 06/24/2005 06:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 44 14 77 255 12.7 0 13.3 12.5 06/24/2005 06:10:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 44 9 54 255 13 0.1 13.5 12.7 06/24/2005 06:20:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 33 10 41 255 13.3 0 13.8 13 06/24/2005 06:30:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 44 12 32 255 13.4 0 13.8 13.3 06/24/2005 06:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 37 19 28 255 13.7 0.1 14.1 13.5 06/24/2005 06:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 71 16 37 255 14.2 0.3 14.9 13.8 06/24/2005 07:00:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 21 10 17 255 15.2 0.3 16 14.6 06/24/2005 07:10:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 33 17 16 255 16.4 0.2 16.8 15.7 06/24/2005 07:20:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 21 12 33 255 17 0 17.4 16.8 06/24/2005 07:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 359 17 11 255 17.7 0.2 18 17.1 06/24/2005 07:40:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.9 0.5 1.9 0.4 15 16 27 255 17.3 0.2 18 16.8 06/24/2005 07:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 32 53 78 255 16.4 0.3 17.4 16.3 06/24/2005 08:00:00 0.6 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 347 16 323 255 16.8 0.5 17.7 16.3 06/24/2005 08:10:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.1 0.6 2.6 0.4 9 22 19 255 18.2 0.2 18.8 17.7 06/24/2005 08:20:00 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 27 90 74 255 18 0.2 18.8 17.7 06/24/2005 08:30:00 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.1 0.4 2.3 0.4 32 32 24 255 17.3 0.2 18 16.8 06/24/2005 08:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 56 13 23 255 17.3 0.2 17.7 16.8 06/24/2005 08:50:00 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.6 0.4 1.9 0.4 67 76 116 255 18.1 0.4 19.1 17.4 06/24/2005 09:00:00 1.4 0.7 3 0.4 1.3 0.8 3 0.4 1.3 0.7 3 0.4 213 29 206 255 19 0 19.7 18.8 06/24/2005 09:10:00 1.6 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.6 0.7 3.8 0.4 211 43 202 255 19.2 0.1 20 18.8 06/24/2005 09:20:00 1.4 0.5 3 0.4 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 208 39 222 255 19.2 0.2 19.7 18.8 06/24/2005 09:30:00 1.6 0.5 2.6 0.4 1.7 0.5 3 0.4 1.7 0.6 3 0.4 208 29 195 255 19.5 0.1 20 19.4 06/24/2005 09:40:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.9 0.6 3.4 0.4 143 86 242 255 19.7 0.2 20.5 19.4 06/24/2005 09:50:00 1.2 0.7 3 0.4 1.2 0.7 3.4 0.4 1.2 0.7 3.4 0.4 198 39 171 255 19.8 0.1 20.3 19.4 06/24/2005 10:00:00 1.8 1 3.4 0.4 1.8 1 3.8 0.4 1.8 1 3.4 0.4 305 76 272 255 19.9 0.2 20.5 19.4 06/24/2005 10:10:00 1.3 0.8 3.4 0.4 1.3 0.9 3 0.4 1.2 0.7 3.4 0.4 205 47 235 255 20 0.1 20.5 19.7 06/24/2005 10:20:00 1.8 0.7 4.2 0.4 1.9 0.6 4.2 0.4 1.7 0.6 3.4 0.4 195 33 201 255 20.1 0 20.5 20 06/24/2005 10:30:00 1.6 0.7 3 0.4 1.6 0.7 3.4 0.4 1.4 0.8 3.8 0.4 257 30 254 255 20.3 0 20.8 20 06/24/2005 10:40:00 1.3 0.8 3 0.4 1.2 0.9 3.4 0.4 1.4 0.8 3 0.4 216 28 219 255 19.9 0 20.5 19.7 06/24/2005 10:50:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 233 26 186 255 20.9 0.3 22 20.3 06/24/2005 11:00:00 2.8 0.8 5.3 0.4 2.8 0.8 5.3 0.7 2.3 1.1 5.3 0.4 298 26 291 255 21.6 0 22 21.4 06/24/2005 11:10:00 2.8 1.1 5.7 0.4 2.7 1.1 5.7 0.4 2.2 1.1 6.1 0.4 287 39 297 255 21.6 0 21.7 21.4 06/24/2005 11:20:00 2.9 0.9 4.9 0.7 2.8 0.9 4.9 0.7 2.7 1 5.3 0.4 289 32 294 255 21.4 0 22 21.1 06/24/2005 11:30:00 2.7 1.1 5.3 0.4 2.6 1.1 5.3 0.7 2.2 1.2 5.7 0.4 249 49 342 255 21.7 0.2 22.3 21.4 06/24/2005 11:40:00 2.8 1 5.3 0.4 2.8 1 5.7 0.4 2.4 1.1 4.9 0.4 264 24 256 255 21.6 0.2 22.6 21.1 06/24/2005 11:50:00 2.5 1 4.9 0.4 2.5 1.1 4.9 0.4 2.2 1 4.9 0.4 248 43 358 255 21.3 0.1 21.7 21.1 06/24/2005 12:00:00 3 1 5.3 0.4 2.9 1.1 5.3 0.4 2.3 1.1 4.9 0.4 284 41 304 255 21.8 0.2 22.3 21.1 06/24/2005 12:10:00 2.6 1 5.3 0.4 2.5 1 4.9 0.7 2.1 0.9 4.6 0.4 251 32 241 255 22.1 0 22.6 21.7 06/24/2005 12:20:00 2.8 1.2 6.1 0.4 2.8 1.2 5.7 0.7 2.4 1.3 6.1 0.4 286 30 309 255 22 0 22.3 21.7 06/24/2005 12:30:00 3 1 5.3 0.4 3 1 5.3 0.4 2.5 1.1 5.3 0.4 281 33 310 255 21.8 0 22.3 21.7 06/24/2005 12:40:00 3 1.1 5.7 0.7 3 1.1 5.7 0.4 2.5 1.1 5.3 0.4 286 22 291 255 22 0 22.3 21.7 06/24/2005 12:50:00 2.7 1.3 5.7 0.4 2.6 1.4 5.7 0.4 2.2 1.5 5.7 0.4 300 36 288 255 21.5 0.2 22.3 21.1 06/24/2005 13:00:00 2.6 1.3 5.7 0.4 2.6 1.3 5.7 0.4 2.3 1.2 5.7 0.4 274 35 287 255 21.9 0.2 22.3 21.7 06/24/2005 13:10:00 3 1.1 5.7 0.4 3 1.1 6.1 0.7 2.7 1.2 5.7 0.4 286 33 277 255 22.1 0 22.6 22 06/24/2005 13:20:00 2.6 1.2 5.3 0.4 2.5 1.1 4.9 0.4 2.1 1.1 4.6 0.4 313 56 12 255 22.5 0.1 22.9 22 06/24/2005 13:30:00 2.4 1 5.7 0.4 2.4 1.1 5.3 0.4 2.1 1.1 5.3 0.4 271 29 300 255 22.7 0 22.9 22.3 06/24/2005 13:40:00 2.4 1.1 5.3 0.4 2.5 1.1 5.3 0.4 2 0.9 4.2 0.4 255 51 251 255 23 0.1 23.5 22.6 06/24/2005 13:50:00 2.9 1 5.3 1.1 2.9 1 5.7 1.1 2.6 1.1 5.3 0.4 315 23 310 255 23 0.2 23.5 22.9 06/24/2005 14:00:00 3.1 1.1 6.1 0.4 3 1.2 6.1 0.4 2.6 1.2 6.8 0.4 295 29 284 255 23.3 0 23.5 23.2 06/24/2005 14:10:00 3.3 1.3 6.8 0.7 3.2 1.2 6.8 0.7 2.7 1.1 5.3 0.4 308 24 328 255 23.8 0.1 24.1 23.5 06/24/2005 14:20:00 2.7 1 4.6 0.4 2.7 1 4.9 0.4 2.2 1 4.6 0.4 289 41 255 255 24.1 0 24.4 23.8 06/24/2005 14:30:00 2.7 0.9 5.3 0.4 2.6 0.9 4.9 0.4 2.3 1 4.9 0.4 313 19 294 255 23.9 0 24.1 23.8 06/24/2005 14:40:00 3.4 1.2 7.6 0.4 3.3 1.3 7.2 0.4 2.9 1.3 6.5 0.4 312 27 307 255 24.1 0.2 24.4 23.8 06/24/2005 14:50:00 3.2 1.3 6.1 0.4 3.2 1.2 6.1 0.7 2.8 1.2 6.1 0.4 299 22 291 255 23.4 0.1 23.8 23.2 06/24/2005 15:00:00 2.6 1 4.6 0.4 2.7 1 4.6 0.4 2.4 0.8 4.2 0.4 254 36 225 255 23.6 0 23.8 23.5 06/24/2005 15:10:00 3.1 1.1 6.5 0.4 3 1.1 5.3 0.4 2.4 1.3 5.3 0.4 277 45 332 255 23.5 0.5 24.1 22.6 06/24/2005 15:20:00 2.9 1.3 7.2 0.4 2.9 1.3 7.2 0.4 2.2 1.2 6.1 0.4 285 39 321 255 23.8 0.5 24.7 22.9 06/24/2005 15:30:00 4.6 1.4 8.8 1.1 4.6 1.4 8.8 1.5 3.8 1.3 7.2 1.1 303 18 308 255 24 0.1 24.4 23.5 06/24/2005 15:40:00 4.2 1.1 6.5 1.5 4.2 1 6.8 1.5 3.6 0.9 5.7 1.1 290 20 308 255 23 0.1 23.5 22.9 06/24/2005 15:50:00 3.9 1.5 7.2 1.1 3.9 1.5 7.2 0.7 3.3 1.5 6.5 0.4 284 21 281 255 23.9 0.3 24.7 23.2 06/24/2005 16:00:00 3.7 1 6.5 1.5 3.7 1.1 6.5 0.7 2.9 1.1 5.7 0.7 290 22 275 255 22.5 0.3 23.5 22.3 06/24/2005 16:10:00 4 0.8 7.6 1.9 4 0.8 7.2 1.5 3.2 1 6.5 0.7 293 24 244 255 21.9 0 22.3 21.7 06/24/2005 16:20:00 4 1.2 6.8 1.5 4 1.2 7.2 1.5 3.3 1.2 6.8 0.7 284 23 281 255 22.3 0 22.9 22 06/24/2005 16:30:00 3.5 1.3 6.1 0.4 3.5 1.4 6.1 0.7 2.9 1.2 6.5 0.4 277 23 271 255 23.3 0.2 23.8 22.9 06/24/2005 16:40:00 3.1 1.2 6.1 0.4 3 1.3 6.1 0.4 2.7 1.2 6.1 0.4 285 29 291 255 23.2 0 23.5 23.2 06/24/2005 16:50:00 4.2 1.2 6.8 1.1 4.2 1.2 6.8 0.7 3.7 1.3 6.1 0.7 286 24 257 255 23.2 0.1 23.5 22.9 06/24/2005 17:00:00 4.5 1.1 7.2 2.3 4.4 1.2 6.8 2.3 3.6 1.2 6.8 0.7 297 18 262 255 23 0.1 23.5 22.9 06/24/2005 17:10:00 3.4 1.1 6.5 1.1 3.4 1.1 6.8 1.1 2.7 1.3 6.8 0.4 280 24 291 255 22.7 0 23.2 22.3 06/24/2005 17:20:00 3.5 0.9 6.1 1.1 3.4 0.9 6.1 0.7 2.7 1 5.7 0.7 292 27 271 255 22.5 0.1 22.9 22 06/24/2005 17:30:00 3.3 1.3 6.1 0.4 3.3 1.3 6.1 0.4 2.5 1.3 4.9 0.4 277 28 288 255 22.1 0 22.6 22 06/24/2005 17:40:00 2.8 1.3 6.1 0.4 2.6 1.4 6.5 0.4 2.4 1.3 6.5 0.4 279 23 290 255 22.4 0 22.9 22 06/24/2005 17:50:00 3.5 1.4 6.5 0.4 3.6 1.3 6.8 0.4 3 1.3 6.1 0.4 281 26 260 255 22.1 0 22.6 22 06/24/2005 18:00:00 3.8 1 6.1 1.5 3.8 1 6.5 1.1 3 1.1 6.5 0.7 281 21 256 255 21.9 0.2 22.6 21.7 06/24/2005 18:10:00 3.3 1 5.7 0.7 3.3 1.1 6.1 0.7 2.6 1.3 5.7 0.4 289 26 292 255 21.9 0.1 22.6 21.4 06/24/2005 18:20:00 4.4 1 6.5 1.5 4.3 1.1 6.5 1.5 3.9 1.1 6.5 1.1 287 17 299 255 21.9 0 22.3 21.7 06/24/2005 18:30:00 3.6 1.5 6.8 0.7 3.6 1.5 6.8 0.4 2.9 1.4 6.1 0.4 291 29 302 255 21.9 0 22 21.7 06/24/2005 18:40:00 4.2 1 6.5 1.5 4.2 1 6.5 1.5 3.4 1.1 5.7 1.1 285 19 274 255 21.7 0 22 21.7 06/24/2005 18:50:00 3.6 1.2 6.5 1.1 3.6 1.2 6.1 1.5 2.9 1.2 6.1 0.4 272 22 254 255 21.4 0.1 22 21.1 06/24/2005 19:00:00 2.6 1.2 5.3 0.4 2.6 1.2 5.3 0.4 2.1 1.1 4.9 0.4 271 20 257 255 21 0 21.1 20.8 06/24/2005 19:10:00 2.8 0.9 4.9 1.1 2.8 0.9 5.3 0.4 2.4 0.9 4.6 0.4 284 20 286 255 20.9 0 21.1 20.8 06/24/2005 19:20:00 3.1 1 5.3 0.4 3.1 1 5.3 0.4 2.4 1 5.3 0.4 284 22 286 255 20.6 0 21.1 20.5 06/24/2005 19:30:00 2.8 0.8 4.9 0.7 2.8 0.9 4.9 0.7 2.2 0.8 4.6 0.4 280 21 271 255 20.5 0 21.1 20.3 06/24/2005 19:40:00 2 0.7 4.6 0.7 2 0.8 4.2 0.4 1.3 0.7 3.8 0.4 284 22 276 255 20.3 0 20.8 20.3 06/24/2005 19:50:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.5 0.6 3.4 0.4 280 19 255 255 20.2 0 20.8 20 06/24/2005 20:00:00 2.2 0.6 4.2 0.7 2.2 0.7 4.2 0.7 1.8 0.6 3.8 0.4 271 15 299 255 20 0 20.5 20 06/24/2005 20:10:00 3 0.9 5.7 0.7 3 0.9 4.9 0.4 2.2 0.9 4.9 0.4 267 17 257 255 19.8 0.1 20.3 19.7 06/24/2005 20:20:00 2.1 0.9 4.2 0.4 2.2 0.8 4.2 0.4 1.5 0.7 3.4 0.4 260 15 244 255 19.7 0 20.3 19.7 06/24/2005 20:30:00 1.2 0.6 3 0.4 1.2 0.6 3 0.4 0.9 0.6 2.6 0.4 275 21 255 255 19.5 0 20.3 19.4 06/24/2005 20:40:00 1.8 1 4.2 0.4 1.8 1.1 4.2 0.4 1.3 1 3.8 0.4 267 20 268 255 19.2 0.1 20 19.1 06/24/2005 20:50:00 2.6 0.9 4.9 0.4 2.6 0.9 4.9 0.4 1.8 0.9 4.2 0.4 269 21 259 255 18.9 0 19.1 18.8 06/24/2005 21:00:00 2.5 1 4.6 0.4 2.6 1 4.6 0.4 1.5 0.8 4.2 0.4 261 15 255 255 18.6 0.1 18.8 18.2 06/24/2005 21:10:00 2.9 0.8 4.9 0.7 2.9 0.8 4.9 0.4 2 1 4.9 0.4 257 16 277 255 18.3 0 18.5 18 06/24/2005 21:20:00 2.2 0.7 4.2 0.7 2.2 0.7 4.6 0.7 1.6 0.7 3.4 0.4 261 21 283 255 17.9 0 18.2 17.7 06/24/2005 21:30:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 1.3 0.6 2.6 0.4 273 17 253 255 17.7 0 17.7 17.4 06/24/2005 21:40:00 1.9 0.7 3.8 0.4 1.9 0.8 3.4 0.4 1.4 0.7 3 0.4 284 17 235 255 17.4 0.1 17.7 17.1 06/24/2005 21:50:00 1.3 0.7 3 0.4 1.4 0.7 3 0.4 1 0.6 2.6 0.4 290 20 275 255 16.9 0 17.1 16.6 06/24/2005 22:00:00 1.1 0.6 3.4 0.4 1.1 0.6 3 0.4 0.7 0.5 1.9 0.4 288 35 303 255 16.1 0.2 16.8 15.7 06/24/2005 22:10:00 1 0.6 2.3 0.4 1 0.6 2.6 0.4 0.6 0.3 1.5 0.4 300 19 280 255 15.3 0.2 15.7 15.2 06/24/2005 22:20:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 321 19 309 255 14.7 0.1 15.5 14.4 06/24/2005 22:30:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.6 0.4 1.9 0.4 315 13 312 255 14.1 0.1 14.6 13.8 06/24/2005 22:40:00 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.5 0.2 1.1 0.4 346 11 352 255 13.7 0 14.1 13.3 06/24/2005 22:50:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 1 4 8 255 13.2 0.1 13.8 13 06/24/2005 23:00:00 1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 340 9 333 255 12.9 0.1 13.3 12.7 06/24/2005 23:10:00 1.2 0.3 2.3 0.4 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 312 8 294 255 12.7 0 13.3 12.5 06/24/2005 23:20:00 0.9 0.4 1.9 0.4 0.9 0.3 1.9 0.4 0.4 0.1 0.7 0.4 301 2 302 255 12.4 0 13 12.2 06/24/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 0 255 255 12.1 0.1 12.5 11.7 06/24/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 0 255 255 11.7 0 12.2 11.7 06/24/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 330 43 255 255 11.7 0 11.9 11.4 06/25/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 255 255 11.4 0 11.9 11.1 06/25/2005 00:10:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 342 38 298 255 11.4 0 11.7 11.4 06/25/2005 00:20:00 0.9 0.3 1.5 0.4 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 289 5 298 255 11.4 0 11.7 11.4 06/25/2005 00:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 286 0 286 255 11.3 0 11.7 11.1 06/25/2005 00:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 286 255 11.2 0 11.7 11.1 06/25/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 11.3 0 11.7 11.1 06/25/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 11 0 11.4 10.9 06/25/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 10.8 0 11.4 10.6 06/25/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 10.5 0 10.9 10.3 06/25/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 10 0 10.6 9.8 06/25/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.5 1.9 0.4 242 56 162 255 9.8 0 9.8 9.6 06/25/2005 01:50:00 1.3 0.5 1.9 0.4 1.2 0.5 1.9 0.4 1.2 0.4 1.9 0.4 160 0 160 255 9.6 0 9.8 9.6 06/25/2005 02:00:00 1.5 0.4 2.3 0.7 1.5 0.4 2.3 0.7 0.7 0.4 1.5 0.4 143 11 160 255 9.3 0.1 9.6 9 06/25/2005 02:10:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 0.8 0.4 1.9 0.4 119 6 115 255 9 0 9 8.8 06/25/2005 02:20:00 1.1 0.4 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 117 0 117 255 8.7 0.1 9 8.5 06/25/2005 02:30:00 1.4 0.2 1.9 1.1 1.4 0.2 1.9 1.1 0.4 0 0.4 0.4 116 2 117 255 8.6 0 8.8 8.5 06/25/2005 02:40:00 1.4 0.3 1.9 0.4 1.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 103 9 113 255 8.5 0 8.8 8.5 06/25/2005 02:50:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 0.9 0.4 1.5 0.4 101 11 98 255 8.1 0.1 8.5 8 06/25/2005 03:00:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 1.2 0.3 2.3 0.4 108 9 103 255 7.9 0 8.3 7.8 06/25/2005 03:10:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.3 0.5 2.3 0.4 118 11 108 255 7.8 0 8 7.8 06/25/2005 03:20:00 2 0.4 3 0.7 2 0.4 3 1.1 1 0.5 2.3 0.4 114 9 115 255 7.8 0 7.8 7.8 06/25/2005 03:30:00 1.8 0.5 3 0.4 1.8 0.5 3 0.7 0.7 0.4 1.9 0.4 119 10 101 255 7.6 0 7.8 7.5 06/25/2005 03:40:00 2.1 0.5 3.4 1.1 2.1 0.4 3 0.7 1 0.5 2.3 0.4 115 8 119 255 7.6 0 7.8 7.5 06/25/2005 03:50:00 2 0.4 3.4 1.1 1.9 0.4 3 1.1 1.3 0.4 2.6 0.4 126 11 106 255 7.6 0 7.8 7.5 06/25/2005 04:00:00 2.1 0.5 3.4 0.4 2.1 0.5 3.4 0.7 1.4 0.5 2.6 0.4 124 10 109 255 7.6 0 7.8 7.5 06/25/2005 04:10:00 1.9 0.5 3.8 0.7 1.9 0.6 4.2 0.4 1.6 0.6 3 0.4 126 11 129 255 7.6 0 7.8 7.5 06/25/2005 04:20:00 2.5 0.5 3.4 0.7 2.5 0.6 3.8 0.7 1.9 0.5 3.4 0.7 124 12 138 255 8.3 0.2 8.5 7.8 06/25/2005 04:30:00 1.9 0.5 3 0.4 2 0.5 3.4 0.7 1.3 0.4 2.6 0.4 122 11 111 255 8.3 0 8.5 8.3 06/25/2005 04:40:00 2.2 0.5 3.8 1.1 2.2 0.5 3.8 0.7 1.2 0.4 2.3 0.4 122 13 108 255 8.4 0 8.8 8.3 06/25/2005 04:50:00 2.4 0.6 4.2 0.7 2.4 0.6 3.8 0.7 1.8 0.5 3.4 0.7 125 14 106 255 9.1 0.3 9.8 8.5 06/25/2005 05:00:00 1.6 0.8 3.4 0.4 1.6 0.8 3.8 0.4 1.1 0.7 3.4 0.4 106 22 126 255 10.4 0.3 11.1 9.8 06/25/2005 05:10:00 0.7 0.5 2.3 0.4 0.8 0.5 2.6 0.4 0.5 0.3 1.9 0.4 92 22 109 255 11.4 0.2 11.7 10.9 06/25/2005 05:20:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 79 4 92 255 10.9 0.3 11.7 10.3 06/25/2005 05:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 72 11 69 255 9.9 0.3 10.6 9.3 06/25/2005 05:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 120 0 119 255 9.6 0.3 10.3 9.3 06/25/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 128 1 129 255 11.3 0.6 12.5 10.3 06/25/2005 06:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 145 23 129 255 13 0.3 13.5 12.5 06/25/2005 06:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 160 5 161 255 13.7 0.2 14.6 13.5 06/25/2005 06:20:00 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 64 36 12 255 14.9 0.4 15.7 14.4 06/25/2005 06:30:00 1 0.4 2.3 0.4 1 0.4 2.6 0.4 0.9 0.4 1.9 0.4 28 9 22 255 15.2 0.1 16 15.2 06/25/2005 06:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 27 0 27 255 16 0.3 16.6 15.5 06/25/2005 06:50:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 33 22 24 255 16.1 0 16.3 16 06/25/2005 07:00:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 6 6 1 255 16.5 0 16.8 16.3 06/25/2005 07:10:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1 15 23 255 16.4 0 16.8 16.3 06/25/2005 07:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 358 15 354 255 16.7 0.2 17.1 16.3 06/25/2005 07:30:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.9 0.4 6 4 4 255 17.2 0.1 17.7 16.8 06/25/2005 07:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 18 13 5 255 17.1 0 17.7 16.8 06/25/2005 07:50:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 3 33 41 255 17.6 0.3 18.2 16.8 06/25/2005 08:00:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 331 35 317 255 17.8 0.2 18.2 17.4 06/25/2005 08:10:00 1.2 0.6 3 0.4 1.2 0.7 3 0.4 1.1 0.6 2.6 0.4 341 45 308 255 18 0.1 18.2 17.4 06/25/2005 08:20:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 1.3 0.5 2.6 0.4 313 26 302 255 17.7 0.2 18.2 17.1 06/25/2005 08:30:00 1.7 0.7 3.8 0.4 1.6 0.7 3.8 0.4 1.5 0.6 3.4 0.4 308 18 313 255 18.2 0.4 19.1 17.7 06/25/2005 08:40:00 1.8 0.8 4.2 0.4 1.7 0.8 4.2 0.4 1.3 0.8 3 0.4 327 72 11 255 18.8 0 19.4 18.5 06/25/2005 08:50:00 1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.6 2.6 0.4 323 49 45 255 19.2 0.1 19.7 18.8 06/25/2005 09:00:00 1.4 0.7 3 0.4 1.4 0.6 3.4 0.4 1.2 0.6 2.6 0.4 293 36 305 255 19.4 0 19.7 19.1 06/25/2005 09:10:00 1.8 0.6 3 0.4 1.8 0.7 3.4 0.4 1.6 0.8 3 0.4 272 43 281 255 19 0 19.4 18.8 06/25/2005 09:20:00 1.8 0.7 3.4 0.4 1.7 0.7 3.8 0.4 1.5 0.8 3.4 0.4 307 30 287 255 19.7 0.1 20.5 19.4 06/25/2005 09:30:00 2.2 0.6 3.8 0.4 2.3 0.6 3.8 0.4 1.9 0.6 3 0.4 263 53 233 255 19.8 0 20.5 19.4 06/25/2005 09:40:00 1.5 0.8 3 0.4 1.6 0.7 3 0.4 1.4 0.7 3 0.4 235 49 207 255 20 0 20.5 19.7 06/25/2005 09:50:00 1.7 0.7 3.4 0.4 1.7 0.7 3.8 0.4 1.6 0.6 3.8 0.4 240 90 339 255 20 0 20.3 19.7 06/25/2005 10:00:00 1.6 0.9 3.8 0.4 1.7 0.9 3.8 0.4 1.6 0.7 3 0.4 268 24 274 255 21 0.3 21.1 20.3 06/25/2005 10:10:00 1.4 0.8 3 0.4 1.4 0.8 3.4 0.4 1.2 0.8 3.4 0.4 290 53 262 255 20.6 0.3 21.4 20.3 06/25/2005 10:20:00 2.6 0.7 4.6 0.7 2.5 0.6 4.6 0.7 2.2 0.7 4.2 0.4 308 14 322 255 19.7 0.3 20.3 19.4 06/25/2005 10:30:00 3.1 0.7 4.6 0.7 3 0.7 4.6 0.7 2.5 0.8 4.2 0.4 303 19 300 255 19.6 0.1 20 19.4 06/25/2005 10:40:00 2.1 0.9 3.8 0.4 2.1 0.8 4.2 0.4 1.9 0.9 3.8 0.4 289 32 288 255 19.5 0 19.7 19.4 06/25/2005 10:50:00 2.5 0.9 4.9 0.4 2.5 1 4.9 0.4 2.1 1 4.6 0.4 317 28 302 255 19.7 0 20 19.7 06/25/2005 11:00:00 3.1 1 5.3 1.1 3.1 1 5.3 0.7 2.5 1 4.9 0.4 304 18 291 255 19.5 0 19.7 19.4 06/25/2005 11:10:00 2 1 4.6 0.4 1.9 1 4.6 0.4 1.6 0.8 3.8 0.4 295 27 329 255 20.1 0.4 21.1 19.4 06/25/2005 11:20:00 3.4 1 6.1 1.5 3.3 1 6.1 1.1 3.1 1.2 6.8 0.7 299 26 306 255 21.9 0.1 22.3 21.1 06/25/2005 11:30:00 3.1 1.1 6.1 0.7 3.1 1.2 6.1 0.4 2.7 1.1 5.7 0.4 294 35 297 255 22.3 0 22.9 22 06/25/2005 11:40:00 3.1 1.1 6.1 0.7 3 1.1 6.1 0.4 2.8 1.2 5.7 0.4 311 41 292 255 21.9 0.2 22.9 21.7 06/25/2005 11:50:00 2.8 1.2 5.3 0.4 2.8 1.2 4.9 0.4 2.3 1.3 5.3 0.4 295 49 283 255 22.1 0.3 22.9 21.7 06/25/2005 12:00:00 3.1 0.7 4.6 1.1 3 0.7 4.6 1.1 2.7 0.8 4.6 0.7 310 20 295 255 21.9 0 22.3 21.7 06/25/2005 12:10:00 3 0.8 5.3 0.7 2.9 0.8 4.9 0.7 2.5 0.8 4.2 0.4 310 33 307 255 22.3 0.1 22.9 22 06/25/2005 12:20:00 3 1.2 6.1 1.1 3 1.2 5.7 1.1 2.6 1 6.1 0.7 309 32 275 255 22.7 0 22.9 22.6 06/25/2005 12:30:00 3.8 1.3 7.2 0.7 3.7 1.3 6.8 1.1 3.3 1.1 6.1 1.1 316 16 303 255 22.4 0 22.9 22.3 06/25/2005 12:40:00 3.9 1 6.1 0.7 3.9 1 6.1 1.5 3.5 1 5.7 1.1 299 32 255 255 22.7 0 23.2 22.6 06/25/2005 12:50:00 4 1 7.2 1.9 3.9 0.9 7.2 1.9 3.4 1 7.6 1.5 304 23 296 255 22.8 0 23.2 22.6 06/25/2005 13:00:00 3.8 1.1 6.5 1.1 3.6 1 6.1 0.4 3.2 1.2 6.8 0.4 320 29 333 255 22.9 0.1 23.5 22.6 06/25/2005 13:10:00 3.7 1.4 7.6 0.4 3.6 1.3 7.2 0.4 3 1.3 6.1 0.4 293 30 306 255 23.3 0 23.5 23.2 06/25/2005 13:20:00 3 1.2 6.1 0.4 2.9 1.2 6.5 0.4 2.5 1 5.7 0.4 292 32 261 255 23.6 0.1 23.8 23.5 06/25/2005 13:30:00 4 1.2 6.5 0.7 3.9 1.2 6.5 0.4 3.4 1.2 6.5 0.4 298 36 269 255 23.8 0 24.1 23.8 06/25/2005 13:40:00 3.5 1.2 6.5 0.4 3.5 1.3 6.5 0.4 2.8 1.3 6.5 0.4 281 26 281 255 23.9 0 24.1 23.8 06/25/2005 13:50:00 4.5 1.5 7.6 0.7 4.5 1.5 7.6 0.7 3.7 1.3 6.8 0.4 233 36 217 255 22.6 1 24.1 20.8 06/25/2005 14:00:00 3.8 1.3 8 0.7 3.9 1.4 7.2 0.7 3.1 1.3 7.6 0.4 193 22 192 255 19.7 0.5 20.8 19.1 06/25/2005 14:10:00 3.2 1 6.5 0.7 3.3 1 6.5 0.7 2.6 0.9 5.3 0.4 201 22 191 255 19.1 0 19.7 18.8 06/25/2005 14:20:00 2.7 1 5.3 0.4 2.7 1 5.3 0.4 2.2 0.8 4.9 0.4 207 24 231 255 19.5 0 20 19.1 06/25/2005 14:30:00 3.5 0.8 5.3 1.1 3.4 0.8 5.3 0.7 3 0.9 4.9 0.4 222 16 211 255 19.6 0 20 19.4 06/25/2005 14:40:00 2.9 0.9 4.9 0.4 2.9 0.8 4.6 0.4 2.2 0.8 4.9 0.4 231 19 226 255 19.6 0 19.7 19.4 06/25/2005 14:50:00 3.2 0.8 4.9 0.7 3.2 0.7 4.9 1.5 2.3 0.7 4.2 0.4 218 21 230 255 19.5 0 20 19.4 06/25/2005 15:00:00 2.8 0.8 4.6 1.1 2.8 0.8 4.6 0.7 2.1 0.8 4.6 0.4 203 18 196 255 19.2 0 19.4 18.8 06/25/2005 15:10:00 2.8 0.8 4.9 0.7 2.9 0.8 4.9 1.1 2.2 0.8 4.6 0.4 203 20 216 255 19 0.1 19.4 18.8 06/25/2005 15:20:00 2.2 0.7 4.2 0.4 2.3 0.7 4.2 0.4 1.5 0.7 3.4 0.4 203 24 202 255 19.2 0.2 20 18.8 06/25/2005 15:30:00 2.8 0.8 5.3 0.4 2.7 0.9 5.3 0.4 2.2 0.8 3.8 0.4 220 15 212 255 19.8 0.3 20.5 19.4 06/25/2005 15:40:00 2.9 0.6 4.2 0.7 2.9 0.6 4.2 0.7 2.4 0.8 4.2 0.4 228 21 225 255 20.5 0 21.1 20.3 06/25/2005 15:50:00 2.1 0.7 3.8 0.4 2.2 0.6 3.8 0.7 1.7 0.7 3.8 0.4 217 18 228 255 20.2 0.2 20.8 19.7 06/25/2005 16:00:00 2.3 0.9 3.8 0.4 2.3 0.8 3.8 0.4 1.8 0.8 3.8 0.4 213 15 215 255 19.7 0.2 20.3 19.4 06/25/2005 16:10:00 2.1 0.5 3.8 0.7 2.1 0.5 3.8 0.4 1.6 0.6 3.4 0.4 210 22 220 255 19.5 0 20 19.4 06/25/2005 16:20:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 1.6 0.6 3 0.4 225 15 238 255 19.5 0 20 19.4 06/25/2005 16:30:00 1.7 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 211 17 212 255 19.7 0 20 19.4 06/25/2005 16:40:00 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.4 0.5 3 0.4 225 14 215 255 19.9 0 20.5 19.7 06/25/2005 16:50:00 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 237 13 268 255 20.2 0 20.8 20 06/25/2005 17:00:00 2 0.8 3.4 0.4 2.1 0.7 3.8 0.4 1.7 0.7 3.4 0.4 196 17 212 255 20.2 0 20.5 20 06/25/2005 17:10:00 1.1 0.7 2.6 0.4 1.2 0.7 3 0.4 0.8 0.6 2.6 0.4 223 21 188 255 20 0.2 20.5 19.7 06/25/2005 17:20:00 2 0.9 3.4 0.4 2 0.9 3.4 0.4 1.6 0.8 3 0.4 203 18 213 255 20 0.2 20.5 19.4 06/25/2005 17:30:00 1.7 0.7 3.8 0.4 1.7 0.8 3.8 0.4 1.3 0.6 3 0.4 198 35 212 255 19.5 0.1 20.3 19.4 06/25/2005 17:40:00 1.6 0.8 3.4 0.4 1.7 0.8 3 0.4 1.4 0.7 3.4 0.4 223 15 231 255 20.2 0.1 20.8 20 06/25/2005 17:50:00 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 216 10 218 255 19.7 0.2 20.5 19.4 06/25/2005 18:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 257 10 213 255 19.2 0.1 19.7 19.1 06/25/2005 18:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.1 0.4 226 30 252 255 20 0.3 20.5 19.4 06/25/2005 18:20:00 0.5 0.3 1.9 0.4 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 311 69 252 255 20.5 0.3 21.1 20.3 06/25/2005 18:30:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1 0.5 2.3 0.4 7 28 16 255 21.1 0 21.7 20.8 06/25/2005 18:40:00 0.9 0.4 1.9 0.4 0.9 0.4 2.3 0.4 0.9 0.5 2.3 0.4 342 22 355 255 21.1 0.2 21.7 20.5 06/25/2005 18:50:00 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 320 33 354 255 20.5 0 21.1 20.3 06/25/2005 19:00:00 1.9 0.5 3 0.4 1.9 0.5 3.4 0.4 1.8 0.5 3 0.4 294 10 284 255 20.2 0.1 20.5 20 06/25/2005 19:10:00 1.4 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.4 0.5 2.6 0.4 297 17 292 255 20 0 20.5 19.7 06/25/2005 19:20:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 305 13 297 255 19.6 0.1 20 19.4 06/25/2005 19:30:00 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.7 0.5 3 0.4 296 11 302 255 19.4 0 20 19.4 06/25/2005 19:40:00 1.3 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 291 11 294 255 19.3 0 20 19.1 06/25/2005 19:50:00 1.2 0.4 1.9 0.4 1.2 0.4 2.6 0.4 1.1 0.4 1.9 0.4 279 11 280 255 19 0 19.4 18.8 06/25/2005 20:00:00 1.2 0.6 2.6 0.4 1.3 0.7 2.6 0.4 1 0.6 2.3 0.4 261 8 266 255 18.5 0.1 18.8 18.2 06/25/2005 20:10:00 1.8 0.7 3 0.4 1.8 0.7 3 0.4 1.2 0.6 2.6 0.4 249 10 259 255 18.2 0 18.2 18 06/25/2005 20:20:00 1.6 0.5 2.6 0.4 1.6 0.4 3 0.4 1.1 0.5 3 0.4 247 12 251 255 17.8 0 18 17.4 06/25/2005 20:30:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 1.2 0.6 2.6 0.4 249 10 252 255 17.5 0.1 17.7 17.1 06/25/2005 20:40:00 2.4 0.8 4.6 0.7 2.5 0.8 4.6 0.7 1.8 0.7 4.2 0.4 256 17 252 255 17.4 0 17.7 17.1 06/25/2005 20:50:00 2.7 0.6 4.6 1.5 2.6 0.6 4.6 0.7 1.7 0.7 3.4 0.4 248 14 252 255 17.5 0 17.7 17.1 06/25/2005 21:00:00 2.6 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.7 0.6 3.8 0.4 244 13 246 255 17.1 0 17.4 16.8 06/25/2005 21:10:00 2.6 0.6 3.8 1.1 2.5 0.6 4.2 1.1 1.8 0.6 3.8 0.4 250 14 238 255 16.8 0 17.1 16.8 06/25/2005 21:20:00 2.3 0.8 4.2 0.4 2.3 0.8 4.6 0.4 1.5 0.8 4.2 0.4 246 21 237 255 16.8 0 17.1 16.6 06/25/2005 21:30:00 2.4 0.7 3.8 1.1 2.4 0.7 3.8 0.4 1.6 0.7 3.4 0.4 252 17 249 255 16.6 0.1 17.1 16.3 06/25/2005 21:40:00 3.4 0.9 5.7 1.1 3.4 0.9 5.7 1.1 2.5 1 5.3 0.4 259 22 266 255 16.3 0.1 16.6 16.3 06/25/2005 21:50:00 3.3 0.9 5.3 1.1 3.3 0.8 5.3 1.5 2.3 1 4.6 0.4 261 18 249 255 16 0 16.6 15.7 06/25/2005 22:00:00 3.2 1.2 6.1 0.4 3.2 1.2 6.1 0.4 2.2 1.2 5.7 0.4 261 22 253 255 15.6 0.1 16.3 15.5 06/25/2005 22:10:00 3 0.8 5.7 1.1 2.9 0.9 4.9 1.1 2.2 0.8 4.6 0.4 260 22 296 255 15.4 0.1 15.7 15.2 06/25/2005 22:20:00 3.5 0.9 5.7 1.1 3.5 1 5.7 1.1 2.7 0.8 4.9 0.7 261 18 253 255 15.4 0.1 15.7 15.2 06/25/2005 22:30:00 3.1 1.2 5.7 0.7 3.1 1.2 6.1 0.4 2.1 1.2 5.3 0.4 266 20 268 255 15.2 0.2 15.7 14.9 06/25/2005 22:40:00 3.4 1 6.1 1.1 3.3 1 6.1 0.7 2.3 0.9 4.9 0.4 261 20 246 255 14.9 0.1 15.5 14.6 06/25/2005 22:50:00 2.7 1 5.7 0.7 2.7 1 5.7 0.4 1.8 1 5.3 0.4 264 24 267 255 14.7 0.1 15.2 14.6 06/25/2005 23:00:00 2.4 0.9 5.7 0.4 2.4 0.9 4.9 0.4 1.8 0.8 4.2 0.4 259 24 274 255 14.5 0 14.9 14.4 06/25/2005 23:10:00 1.7 0.8 4.2 0.4 1.8 0.8 3.8 0.4 1.1 0.7 3 0.4 267 22 223 255 14.4 0 14.9 14.4 06/25/2005 23:20:00 1.7 1 3.8 0.4 1.8 1 3.8 0.4 1.1 0.7 3 0.4 250 24 294 255 14.2 0.1 14.6 14.1 06/25/2005 23:30:00 2 0.8 4.6 0.4 2.1 0.8 4.2 0.4 1.5 0.8 3.8 0.4 248 22 257 255 14.2 0.2 14.6 14.1 06/25/2005 23:40:00 2.7 1 5.3 0.7 2.7 1 5.3 0.4 1.8 1 4.9 0.4 245 19 230 255 14 0.1 14.6 13.8 06/25/2005 23:50:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.4 0.7 3.8 0.4 237 22 270 255 13.9 0 14.6 13.8 06/26/2005 00:00:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 220 41 252 255 13.9 0 14.6 13.5 06/26/2005 00:10:00 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.4 2.3 0.4 193 10 192 255 13.5 0 14.4 13.3 06/26/2005 00:20:00 1.4 0.4 2.3 0.7 1.7 0.4 2.6 0.7 1.1 0.4 2.3 0.4 175 8 177 255 13.1 0.2 13.3 12.7 06/26/2005 00:30:00 1.7 0.5 2.6 0.7 1.8 0.4 2.6 0.7 1.3 0.5 2.6 0.4 157 14 175 255 12.5 0.1 12.7 12.2 06/26/2005 00:40:00 2.1 0.3 3.4 1.5 2.2 0.3 3.4 1.5 1.4 0.4 2.6 0.7 149 9 153 255 11.9 0.1 12.2 11.7 06/26/2005 00:50:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 158 9 158 255 11.4 0.1 12.2 11.1 06/26/2005 01:00:00 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 161 5 160 255 10.9 0.1 11.4 10.6 06/26/2005 01:10:00 1.2 0.5 2.6 0.4 1.5 0.5 2.6 0.7 1.2 0.4 2.3 0.4 182 10 202 255 10.5 0 10.9 10.6 06/26/2005 01:20:00 2.1 0.4 2.6 1.1 2.2 0.3 3 1.1 1.4 0.3 2.3 0.7 196 8 186 255 10.4 0 10.6 10.3 06/26/2005 01:30:00 1.7 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.1 0.3 1.9 0.4 197 6 208 255 10.3 0 10.6 10.3 06/26/2005 01:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 172 29 181 255 10.4 0 10.6 10.3 06/26/2005 01:50:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 79 10 70 255 10.2 0 10.6 10.1 06/26/2005 02:00:00 1.3 0.4 2.3 0.4 1.3 0.5 1.9 0.4 0.6 0.3 1.5 0.4 92 15 118 255 10 0 10.3 9.8 06/26/2005 02:10:00 1 0.3 1.9 0.4 1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 125 6 130 255 9.7 0 9.8 9.6 06/26/2005 02:20:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 1.5 0.4 2.6 0.7 133 6 131 255 9.5 0 9.6 9.3 06/26/2005 02:30:00 3 0.3 3.4 1.9 3 0.2 3.4 1.9 2.2 0.3 3 1.5 142 7 146 255 9.3 0 9.6 9 06/26/2005 02:40:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.5 2.1 0.4 3 1.1 155 4 153 255 9.2 0 9.3 9 06/26/2005 02:50:00 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1.2 0.3 1.9 0.4 146 6 154 255 9.4 0 9.3 9.3 06/26/2005 03:00:00 1.9 0.4 3 0.7 1.9 0.4 3 0.7 1.4 0.4 2.3 0.7 130 8 126 255 9.4 0 9.6 9.3 06/26/2005 03:10:00 2 0.4 3 1.1 2 0.4 3 0.7 1.3 0.4 2.3 0.4 129 8 119 255 9.5 0 9.6 9.3 06/26/2005 03:20:00 1.5 0.4 2.3 0.7 1.5 0.4 2.6 0.7 0.9 0.4 2.3 0.4 129 8 137 255 9.5 0 9.6 9.3 06/26/2005 03:30:00 1.8 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.2 0.4 2.3 0.4 142 9 147 255 9.6 0.1 9.8 9.6 06/26/2005 03:40:00 1.9 0.2 2.3 1.1 2 0.2 2.3 1.1 1.3 0.3 1.9 0.7 145 4 152 255 10.1 0 10.3 9.8 06/26/2005 03:50:00 0.5 0.3 1.5 0.4 0.5 0.4 1.5 0.4 0.4 0.1 1.1 0.4 147 0 146 255 10.3 0 10.6 10.3 06/26/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 146 0 255 255 10.5 0 10.6 10.3 06/26/2005 04:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.3 1.1 0.4 134 22 95 255 10.7 0 10.9 10.6 06/26/2005 04:20:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 89 11 95 255 10.9 0 11.1 10.9 06/26/2005 04:30:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 69 0 69 255 11.1 0 11.1 10.9 06/26/2005 04:40:00 0.7 0.2 1.1 0.4 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 69 0 69 255 11.1 0 11.4 11.1 06/26/2005 04:50:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.4 0.1 0.7 0.4 69 0 69 255 11.2 0 11.4 11.1 06/26/2005 05:00:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.5 0.4 51 17 38 255 11.3 0 11.4 11.1 06/26/2005 05:10:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 1.9 0.4 44 8 49 255 11.5 0 11.7 11.4 06/26/2005 05:20:00 0.6 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 65 17 77 255 11.9 0.3 12.7 11.7 06/26/2005 05:30:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 30 12 49 255 14 0.5 14.6 12.7 06/26/2005 05:40:00 0.7 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 42 10 49 255 15.1 0.3 15.7 14.6 06/26/2005 05:50:00 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 33 10 15 255 15.7 0 16.3 15.5 06/26/2005 06:00:00 1 0.4 2.3 0.4 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 23 17 21 255 15 0 16 14.6 06/26/2005 06:10:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 19 11 30 255 15 0.3 15.7 14.6 06/26/2005 06:20:00 1.5 0.4 2.3 0.7 1.5 0.4 2.3 0.7 1.4 0.4 1.9 0.4 28 13 10 255 16.5 0.2 16.8 15.7 06/26/2005 06:30:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 35 21 34 255 16.3 0.4 17.1 15.7 06/26/2005 06:40:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.7 0.5 2.3 0.4 354 10 355 255 15.7 0 16.3 15.7 06/26/2005 06:50:00 2.6 0.6 3.8 1.1 2.6 0.6 3.8 1.1 2.4 0.7 3.8 0.7 36 15 52 255 15.3 0.2 16 14.9 06/26/2005 07:00:00 2.2 0.5 3 0.4 2.3 0.5 3 1.1 1.9 0.5 3 0.4 41 14 32 255 14.8 0 15.5 14.6 06/26/2005 07:10:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2 0.5 3 0.7 41 13 32 255 15.5 0.5 16.3 14.9 06/26/2005 07:20:00 1.6 0.4 3 0.4 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 25 19 63 255 16.8 0.2 17.4 16.3 06/26/2005 07:30:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 32 18 22 255 16.4 0.2 16.8 16 06/26/2005 07:40:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 52 18 71 255 15.9 0 16.3 15.7 06/26/2005 07:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 67 5 58 255 15.9 0 16.3 15.7 06/26/2005 08:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 126 69 69 255 16.1 0.1 16.6 16 06/26/2005 08:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 238 14 244 255 16.6 0 16.8 16.6 06/26/2005 08:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 244 0 244 255 16.6 0 16.8 16.6 06/26/2005 08:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 120 39 284 255 16.8 0.2 17.1 16.6 06/26/2005 08:40:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 229 22 253 255 17.8 0.2 18.2 17.1 06/26/2005 08:50:00 0.8 0.6 3 0.4 0.8 0.6 3.4 0.4 0.7 0.5 3 0.4 187 35 230 255 18.6 0.1 19.1 18.2 06/26/2005 09:00:00 1.5 0.8 3.4 0.4 1.5 0.8 3 0.4 1.4 0.6 3 0.4 247 20 278 255 20 0.4 21.1 19.1 06/26/2005 09:10:00 2 0.5 3 0.4 2 0.5 3 0.4 1.8 0.5 3.4 0.4 218 20 212 255 19.5 0.3 20.3 18.8 06/26/2005 09:20:00 1.2 0.8 3.4 0.4 1.3 0.7 3.4 0.4 1.2 0.6 2.6 0.4 223 49 284 255 19.5 0.3 20.3 19.1 06/26/2005 09:30:00 1.3 0.8 3 0.4 1.3 0.9 3.4 0.4 1.3 0.8 3.4 0.4 231 56 222 255 20.1 0 20.8 19.7 06/26/2005 09:40:00 1.6 0.9 3.4 0.4 1.7 0.9 3.4 0.4 1.6 0.8 3.8 0.4 219 36 267 255 19.7 0 20 19.4 06/26/2005 09:50:00 1.4 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.5 3 0.4 254 58 184 255 20.1 0 20.3 20 06/26/2005 10:00:00 2.1 0.7 4.6 0.4 2.2 0.7 3.8 0.7 1.7 0.6 3.4 0.4 274 45 312 255 20.5 0.3 21.1 20 06/26/2005 10:10:00 2.3 0.9 4.2 0.4 2.2 0.8 4.2 0.4 2.1 0.8 3.8 0.4 268 43 262 255 21 0.3 21.4 20.5 06/26/2005 10:20:00 2.5 1.1 4.9 0.4 2.5 1.1 4.9 0.4 2.3 1 4.9 0.4 303 36 295 255 21 0 21.1 20.8 06/26/2005 10:30:00 3.1 0.9 4.9 1.1 3.1 0.9 5.3 0.7 2.5 0.9 4.9 0.4 244 24 250 255 20.9 0.1 21.1 20.8 06/26/2005 10:40:00 2.3 0.8 4.9 0.4 2.3 0.8 4.9 0.4 1.9 0.7 3.8 0.4 229 33 244 255 21 0 21.1 20.8 06/26/2005 10:50:00 1.9 1.2 4.6 0.4 1.9 1.2 4.6 0.4 1.7 1 4.2 0.4 227 61 300 255 20.9 0 21.1 20.5 06/26/2005 11:00:00 2.5 1.1 5.3 0.4 2.5 1.1 5.3 0.4 2.1 1 5.3 0.4 243 33 250 255 21 0.1 21.4 20.8 06/26/2005 11:10:00 2.3 0.9 4.6 0.4 2.4 0.9 4.9 0.4 2.1 0.9 3.8 0.4 243 18 237 255 21 0 21.4 20.8 06/26/2005 11:20:00 2.6 1 5.3 0.4 2.6 1 5.3 0.4 2 1 5.3 0.4 225 36 252 255 21.4 0.2 22.3 20.8 06/26/2005 11:30:00 2.4 1.1 4.9 0.4 2.5 1 4.9 0.4 2.2 0.8 4.6 0.4 221 29 263 255 21.8 0.1 22.3 21.7 06/26/2005 11:40:00 2.4 0.9 4.6 0.4 2.5 0.9 4.9 0.4 2.1 0.7 4.6 0.4 254 30 277 255 21.9 0 22.3 21.7 06/26/2005 11:50:00 2 1 4.9 0.4 2.1 0.9 4.9 0.4 1.7 1 4.2 0.4 256 41 255 255 21.7 0.1 22 21.7 06/26/2005 12:00:00 2.6 1.2 5.3 0.4 2.6 1.2 5.3 0.4 2.2 1 4.9 0.4 260 47 290 255 21.9 0.1 22.3 21.7 06/26/2005 12:10:00 2.7 1.1 6.5 0.4 2.8 1.1 6.5 0.4 2.5 1.1 5.3 0.4 258 28 293 255 21.7 0.3 22.3 21.1 06/26/2005 12:20:00 2.7 1 5.7 0.4 2.6 1 5.7 0.4 2.3 0.8 4.9 0.4 285 39 279 255 21.9 0 22.3 21.7 06/26/2005 12:30:00 3.1 1.2 6.1 0.4 3.1 1.2 6.1 0.4 2.6 1.2 6.8 0.4 280 36 319 255 22.4 0 22.9 22 06/26/2005 12:40:00 3.1 1 5.3 0.7 3 1 4.9 0.4 2.7 1.2 5.7 0.4 315 26 331 255 22.2 0 22.9 22 06/26/2005 12:50:00 3.2 1 5.7 0.7 3.1 1 5.7 0.4 2.8 1 5.3 0.4 308 17 288 255 22.4 0 22.9 22.3 06/26/2005 13:00:00 3.3 1 6.1 0.4 3.3 1.1 6.1 0.4 2.9 1 4.9 0.4 290 35 307 255 22.4 0.2 22.9 22.3 06/26/2005 13:10:00 2.7 1 5.7 0.4 2.6 1 5.7 0.4 2.3 1 4.9 0.4 295 26 272 255 22.4 0.3 23.2 22 06/26/2005 13:20:00 2.7 0.9 4.9 0.7 2.6 1 4.9 0.4 2.4 1.1 4.9 0.4 291 29 306 255 23.3 0 23.5 22.9 06/26/2005 13:30:00 2.9 0.9 5.3 0.7 2.8 0.9 5.3 0.7 2.4 1 5.3 0.4 289 19 279 255 22.8 0.1 23.5 22.6 06/26/2005 13:40:00 2.4 1.1 4.6 0.4 2.4 1.1 4.6 0.4 2.1 1.2 5.3 0.4 309 24 313 255 22.9 0.1 23.5 22.6 06/26/2005 13:50:00 3.1 0.9 5.3 0.7 3 1 5.7 0.7 2.6 1 5.7 0.4 303 35 293 255 23.4 0.2 23.8 23.2 06/26/2005 14:00:00 2.9 1.1 5.3 0.7 2.9 1.2 5.7 0.7 2.4 1.2 5.7 0.4 271 29 276 255 23.3 0 23.5 23.5 06/26/2005 14:10:00 3.2 1.2 6.1 0.4 3.1 1.2 5.7 0.4 2.7 1.3 5.7 0.4 293 49 265 255 23.7 0 23.8 23.5 06/26/2005 14:20:00 3.1 0.9 4.9 0.7 2.9 1 4.9 0.7 2.6 0.8 4.2 0.7 309 32 282 255 23.8 0.1 24.1 23.5 06/26/2005 14:30:00 2.2 0.8 3.8 0.4 2.2 0.9 3.8 0.4 1.6 0.9 4.2 0.4 311 45 314 255 24.4 0.4 25.3 23.8 06/26/2005 14:40:00 2.5 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2.2 0.9 4.6 0.4 301 33 279 255 24.7 0.2 25.3 24.4 06/26/2005 14:50:00 2.9 1 5.3 0.4 2.8 1.1 5.3 0.7 2.5 1 4.9 0.7 289 49 274 255 24 0.2 24.7 23.8 06/26/2005 15:00:00 2.8 1.3 5.7 0.4 2.8 1.3 5.7 0.4 2.5 1.4 6.1 0.4 275 32 307 255 24.4 0.5 25.3 23.8 06/26/2005 15:10:00 3.2 0.8 5.3 1.1 3 0.8 5.3 0.7 2.4 0.9 4.6 0.4 299 38 291 255 24.9 0.1 25.3 24.7 06/26/2005 15:20:00 1.6 1 4.2 0.4 1.7 1 4.2 0.4 1.5 0.8 3.4 0.4 226 47 270 255 25.3 0.2 25.6 25 06/26/2005 15:30:00 1.2 0.9 4.6 0.4 1.2 0.9 4.6 0.4 1.4 0.7 3.8 0.4 243 76 316 255 24.9 0.1 25.3 24.7 06/26/2005 15:40:00 2.1 1 4.9 0.4 2.1 0.9 4.9 0.4 1.8 1 4.6 0.4 296 43 290 255 25 0 25.3 24.7 06/26/2005 15:50:00 2.1 0.7 3.4 0.4 2.1 0.7 3.4 0.4 1.6 0.6 3.4 0.4 268 56 198 255 24.9 0 25.3 24.7 06/26/2005 16:00:00 2.4 0.9 4.6 0.4 2.4 0.9 4.6 0.4 2.2 0.7 4.2 0.4 276 28 295 255 25 0.2 25.6 24.7 06/26/2005 16:10:00 2.8 0.9 4.9 0.4 2.6 0.9 4.6 0.4 2.2 0.9 4.2 0.4 327 33 349 255 25 0.1 25.3 24.7 06/26/2005 16:20:00 1.3 0.8 3.4 0.4 1.4 0.8 3.8 0.4 1 0.6 2.6 0.4 280 29 263 255 24.7 0.1 25.3 24.4 06/26/2005 16:30:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.4 0.7 3.4 0.4 299 26 290 255 24.2 0 24.4 24.1 06/26/2005 16:40:00 1.5 0.9 3 0.4 1.5 0.8 3 0.4 1.5 0.8 3.4 0.4 294 12 307 255 23.6 0.2 24.4 23.5 06/26/2005 16:50:00 2.4 2.2 7.6 0.4 2.5 2.1 7.6 0.4 2.3 2 8 0.4 80 98 91 255 24.1 0.3 24.7 23.5 06/26/2005 17:00:00 5.8 1.4 9.1 1.9 5.7 1.3 8.8 2.3 5 1.4 8.8 1.9 105 22 83 255 22.7 0.9 24.1 21.1 06/26/2005 17:10:00 4.3 1 7.6 1.5 4.3 1 7.2 1.9 3.7 1.2 7.2 1.5 100 23 119 255 20.8 0.2 21.1 20.5 06/26/2005 17:20:00 3.5 1.2 6.5 0.7 3.4 1.2 6.1 0.7 3.2 1.1 6.1 0.4 114 23 104 255 20.6 0.2 21.1 20.3 06/26/2005 17:30:00 4.2 1 6.8 1.5 4.2 1 6.8 1.9 3.7 1 6.5 1.1 114 22 122 255 21.3 0.3 22.3 20.8 06/26/2005 17:40:00 4.4 1.1 6.8 1.9 4.4 1.1 6.8 1.9 3.7 1 6.1 0.7 106 20 102 255 21.8 0 22.3 21.4 06/26/2005 17:50:00 3.1 1.1 6.5 0.7 3.2 1.1 6.1 0.7 2.9 1 5.3 0.7 140 30 111 255 22.1 0 22.6 22 06/26/2005 18:00:00 2.8 0.8 4.6 0.7 2.9 0.8 4.6 0.7 2.6 0.8 4.9 0.4 135 23 134 255 21.9 0 22.3 21.7 06/26/2005 18:10:00 3.1 0.9 5.3 1.1 3.1 0.9 4.9 1.1 2.9 0.7 4.9 1.1 112 23 80 255 22.1 0 22.3 22 06/26/2005 18:20:00 3.1 0.9 4.9 0.4 3.1 0.9 5.3 0.4 2.6 1 4.6 0.4 96 22 101 255 22.3 0 22.6 22 06/26/2005 18:30:00 2.4 1.1 4.6 0.4 2.4 1.1 4.9 0.4 2.1 1 4.6 0.4 125 35 104 255 22.1 0.1 22.3 21.7 06/26/2005 18:40:00 3.3 0.7 4.9 1.5 3.3 0.7 4.9 1.1 2.9 0.7 4.9 0.7 105 17 107 255 21.4 0.1 21.7 21.1 06/26/2005 18:50:00 1.7 0.8 4.2 0.4 1.7 0.8 4.2 0.4 1.6 0.8 3.8 0.4 115 23 101 255 20.8 0.1 21.1 20.5 06/26/2005 19:00:00 2.3 1 4.6 0.4 2.2 1 4.6 0.4 1.7 0.9 4.6 0.4 102 17 82 255 20.4 0 20.8 20 06/26/2005 19:10:00 2.4 0.6 3.8 0.7 2.3 0.5 3.4 1.1 1.9 0.5 3 1.1 124 11 104 255 19.8 0.3 20.5 19.4 06/26/2005 19:20:00 1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 131 4 136 255 19 0.2 19.7 18.2 06/26/2005 19:30:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 141 2 134 255 18 0.1 18.8 17.7 06/26/2005 19:40:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.3 0.5 2.3 0.4 135 6 127 255 17.4 0.1 18 17.1 06/26/2005 19:50:00 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 1.6 0.4 2.6 0.7 127 6 124 255 17.2 0 17.1 17.1 06/26/2005 20:00:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 114 11 131 255 16.8 0 17.1 16.8 06/26/2005 20:10:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 113 15 127 255 16.6 0 16.8 16.6 06/26/2005 20:20:00 1.7 0.6 3.4 0.4 1.8 0.5 3 0.4 1.4 0.5 2.6 0.4 124 12 117 255 16.3 0 16.6 16.3 06/26/2005 20:30:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.9 0.5 3 0.4 110 9 122 255 16.6 0.3 17.1 16.3 06/26/2005 20:40:00 1.7 0.5 3 0.4 1.7 0.5 3 0.4 1.4 0.5 2.6 0.4 122 11 108 255 17.1 0 17.1 16.8 06/26/2005 20:50:00 1.6 0.7 3 0.4 1.6 0.7 3.4 0.4 1.2 0.5 2.3 0.4 117 12 127 255 16.7 0 16.8 16.6 06/26/2005 21:00:00 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.7 0.4 2.3 0.4 127 13 144 255 16.4 0 16.8 16.3 06/26/2005 21:10:00 1.9 0.6 3.8 0.7 1.9 0.6 3.4 0.7 1.6 0.5 2.6 0.4 122 11 121 255 16.1 0 16.3 16 06/26/2005 21:20:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2 0.5 3 0.7 116 12 100 255 16 0 16.3 15.7 06/26/2005 21:30:00 2.4 0.5 3.8 1.5 2.4 0.5 3.4 1.5 1.7 0.5 3 0.7 93 8 102 255 16.1 0 16.6 16 06/26/2005 21:40:00 2 0.3 3 1.1 2 0.3 2.6 1.1 1.3 0.3 2.3 0.4 92 6 85 255 15.8 0.1 16.6 15.5 06/26/2005 21:50:00 1.7 0.5 3 0.7 1.7 0.5 3 0.7 1 0.4 2.3 0.4 67 23 56 255 15.4 0.1 15.7 15.2 06/26/2005 22:00:00 1.7 0.5 2.6 0.7 1.7 0.5 3 0.7 1.2 0.4 2.3 0.4 93 28 56 255 15 0.2 15.5 14.6 06/26/2005 22:10:00 2.1 0.6 3.8 0.7 2.1 0.6 3.8 1.1 1.7 0.5 3 0.7 99 12 90 255 14.6 0 15.2 14.4 06/26/2005 22:20:00 3.1 0.6 4.6 1.9 3.1 0.6 4.6 1.9 2.5 0.5 4.2 1.5 71 9 65 255 14.5 0.1 15.2 14.4 06/26/2005 22:30:00 2.6 0.6 4.2 1.1 2.6 0.6 4.2 1.1 1.9 0.5 3.8 0.7 60 17 60 255 14.8 0 15.5 14.6 06/26/2005 22:40:00 3.2 0.7 4.9 1.1 3.3 0.7 4.9 1.1 2.4 0.8 4.6 0.7 63 16 74 255 14.7 0 15.5 14.6 06/26/2005 22:50:00 2.3 0.5 3.8 0.7 2.3 0.5 3.8 1.1 1.5 0.6 3 0.4 68 11 71 255 14.7 0.2 15.5 14.1 06/26/2005 23:00:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.7 0.4 1.9 0.4 46 10 52 255 13.5 0.3 14.6 13 06/26/2005 23:10:00 2.5 0.8 4.6 1.1 2.5 0.8 4.6 1.1 1.8 0.7 4.2 0.7 68 10 70 255 12.7 0 13 12.5 06/26/2005 23:20:00 4 0.8 6.1 1.9 4 0.8 6.1 1.9 3 0.8 4.9 1.1 62 16 56 255 12.7 0.3 13.8 12.5 06/26/2005 23:30:00 3.4 0.7 6.1 1.9 3.5 0.7 5.7 1.5 2.5 0.8 5.3 1.1 68 13 59 255 13.9 0.2 14.6 13.3 06/26/2005 23:40:00 2.8 0.7 4.2 1.5 2.8 0.7 4.6 1.1 2 0.6 3.4 0.4 67 15 48 255 13.9 0 14.4 13.5 06/26/2005 23:50:00 2.1 0.7 4.6 0.7 2.2 0.7 4.2 0.7 1.3 0.7 3.4 0.4 62 13 86 255 13.2 0.2 13.8 12.7 06/27/2005 00:00:00 1.5 0.5 3 0.4 1.5 0.5 3 0.4 0.8 0.4 1.9 0.4 64 12 64 255 12.2 0.2 13 11.9 06/27/2005 00:10:00 2.7 0.5 4.6 1.5 2.7 0.5 4.6 1.5 1.8 0.5 3.4 0.7 72 9 80 255 11.9 0 12.2 11.7 06/27/2005 00:20:00 2.4 0.5 3.4 1.5 2.5 0.5 3.4 1.5 1.8 0.4 3 0.7 80 9 69 255 11.7 0 12.2 11.7 06/27/2005 00:30:00 2.4 0.5 3.8 1.5 2.4 0.5 3.8 1.5 1.7 0.4 3 0.7 86 7 81 255 11.5 0 11.9 11.4 06/27/2005 00:40:00 2.7 0.5 4.2 1.5 2.8 0.5 4.6 1.9 2 0.6 3.8 0.7 67 8 73 255 11.5 0 11.9 11.4 06/27/2005 00:50:00 2.8 0.5 3.8 1.5 2.9 0.5 4.2 1.9 2 0.4 3 1.1 72 9 86 255 11.3 0.1 11.9 11.1 06/27/2005 01:00:00 2.7 0.5 4.6 1.5 2.8 0.5 4.6 1.9 1.7 0.4 3.4 0.7 69 8 74 255 11.1 0.1 11.7 10.9 06/27/2005 01:10:00 1.8 0.4 3 0.7 1.8 0.4 3 0.7 1.1 0.4 2.3 0.4 53 10 51 255 10.6 0 11.1 10.6 06/27/2005 01:20:00 1.6 0.2 2.3 1.1 1.7 0.3 2.3 1.1 1 0.2 1.5 0.4 65 8 79 255 10.6 0 10.6 10.6 06/27/2005 01:30:00 1.7 0.3 2.6 1.1 1.7 0.3 2.6 0.7 0.7 0.3 1.5 0.4 94 7 88 255 10.5 0 10.6 10.3 06/27/2005 01:40:00 1.7 0.3 3 1.1 1.8 0.3 3 1.1 0.5 0.3 1.5 0.4 100 6 86 255 10.3 0 10.9 10.3 06/27/2005 01:50:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 0.8 0.3 1.5 0.4 89 13 97 255 10.1 0 10.6 10.1 06/27/2005 02:00:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 1.3 0.3 1.9 0.7 86 14 104 255 9.9 0 10.3 9.8 06/27/2005 02:10:00 2 0.3 2.6 1.5 2 0.4 3 1.1 0.9 0.3 1.9 0.4 108 5 104 255 9.8 0 10.3 9.6 06/27/2005 02:20:00 2.7 0.6 4.2 1.5 2.6 0.5 4.2 1.1 1.5 0.5 3 0.4 108 8 108 255 9.8 0 10.3 9.8 06/27/2005 02:30:00 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2 0.6 3 0.4 111 10 98 255 9.7 0 10.3 9.6 06/27/2005 02:40:00 2.4 0.6 3.8 0.7 2.4 0.6 3.8 1.1 1.5 0.4 3 0.4 116 11 115 255 9.6 0.1 10.3 9.6 06/27/2005 02:50:00 2.4 0.6 3.8 0.7 2.3 0.6 4.2 0.4 1.4 0.5 3 0.4 108 14 118 255 9.8 0 9.8 9.6 06/27/2005 03:00:00 2.6 0.5 3.8 1.5 2.7 0.4 3.8 1.5 1.7 0.5 3 0.7 104 9 113 255 9.7 0 9.8 9.6 06/27/2005 03:10:00 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 1.8 0.5 3 0.4 103 8 105 255 9.6 0 9.6 9.6 06/27/2005 03:20:00 1.9 0.4 3 1.1 2 0.4 3 1.1 1.1 0.4 2.3 0.4 99 9 104 255 9.4 0 9.6 9.3 06/27/2005 03:30:00 1.4 0.5 2.6 0.4 1.4 0.5 3 0.4 0.5 0.3 1.5 0.4 96 6 115 255 9.4 0 9.6 9.3 06/27/2005 03:40:00 1.2 0.3 1.9 0.4 1.2 0.3 2.3 0.4 0.5 0.2 1.1 0.4 103 6 104 255 9.5 0 9.6 9.6 06/27/2005 03:50:00 1.8 0.6 3.4 0.7 1.8 0.6 3.4 0.4 1 0.4 2.6 0.4 115 8 96 255 9.6 0 9.6 9.6 06/27/2005 04:00:00 2.6 0.3 3.8 1.9 2.6 0.3 3.4 1.9 1.8 0.4 2.6 0.7 106 7 116 255 9.5 0 9.6 9.6 06/27/2005 04:10:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.8 0.5 3 0.4 99 5 102 255 9.6 0 9.8 9.6 06/27/2005 04:20:00 2.4 0.3 3 1.9 2.4 0.3 3 1.9 1.6 0.3 2.3 0.7 105 5 100 255 9.5 0 9.6 9.6 06/27/2005 04:30:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 1.9 0.5 3 0.4 104 8 101 255 9.7 0 10.1 9.6 06/27/2005 04:40:00 2.4 0.3 3.4 1.5 2.4 0.4 3.4 1.5 1.6 0.5 3 0.4 104 6 106 255 10.2 0.2 10.6 9.8 06/27/2005 04:50:00 2.6 0.6 3.8 1.1 2.6 0.6 3.8 1.1 1.8 0.5 3 0.7 108 10 118 255 11.1 0.2 11.7 10.6 06/27/2005 05:00:00 2.5 0.4 3.8 1.5 2.5 0.5 3.8 1.5 1.9 0.4 3 0.7 98 7 108 255 12.7 0.5 13.5 11.7 06/27/2005 05:10:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 0.7 1.7 0.4 2.6 0.4 104 12 98 255 13.8 0.2 14.4 13.5 06/27/2005 05:20:00 2 0.5 3 0.7 2.1 0.5 3.4 0.7 1.6 0.5 3 0.4 100 13 115 255 14.2 0.2 14.6 13.8 06/27/2005 05:30:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.1 0.4 2.3 0.4 80 13 87 255 14.4 0.3 15.2 13.8 06/27/2005 05:40:00 1.6 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 72 13 60 255 15.3 0.3 16.3 14.9 06/27/2005 05:50:00 2.2 0.8 3.8 0.4 2.3 0.8 4.2 0.4 1.9 0.7 3.8 0.4 84 13 92 255 15.7 0 16.3 15.7 06/27/2005 06:00:00 2.1 0.7 4.2 0.4 2.2 0.7 3.8 0.4 1.9 0.6 3.4 0.4 90 19 91 255 16.1 0.1 16.8 16 06/27/2005 06:10:00 2.2 0.6 3.8 0.7 2.2 0.6 4.2 0.7 1.8 0.6 3.4 0.4 86 15 78 255 16.1 0.1 16.8 16 06/27/2005 06:20:00 1.7 0.7 3.4 0.4 1.7 0.7 3 0.4 1.6 0.7 3 0.4 77 17 71 255 16 0.4 16.8 15.2 06/27/2005 06:30:00 2.1 0.4 3 0.7 2.1 0.4 3 1.1 1.7 0.5 2.6 0.4 83 14 56 255 14.6 0.3 15.5 14.1 06/27/2005 06:40:00 2.2 0.4 3.4 0.7 2.2 0.4 3.4 0.7 1.7 0.4 3 0.7 100 11 99 255 14.1 0.1 14.6 13.8 06/27/2005 06:50:00 1.9 0.6 3 0.4 1.9 0.5 2.6 0.4 1.7 0.4 2.6 0.4 104 9 100 255 14.8 0.4 15.7 14.1 06/27/2005 07:00:00 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 84 21 77 255 16.1 0.4 16.8 15.5 06/27/2005 07:10:00 1.1 0.7 2.6 0.4 1.2 0.7 3 0.4 1 0.6 2.6 0.4 86 16 95 255 16.6 0 17.1 16.6 06/27/2005 07:20:00 1.6 0.6 3 0.4 1.7 0.5 3 0.4 1.4 0.6 2.6 0.4 83 16 74 255 17.3 0.2 18 16.8 06/27/2005 07:30:00 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.5 2.3 0.4 62 39 4 255 18.7 0.4 19.4 18 06/27/2005 07:40:00 1.6 0.5 2.6 0.4 1.7 0.6 2.6 0.4 1.4 0.5 2.6 0.4 58 21 63 255 19.5 0 20 19.4 06/27/2005 07:50:00 2 0.5 3.8 0.7 2.1 0.5 3.8 0.7 1.9 0.6 3.4 0.7 47 15 36 255 19.5 0.1 20.3 19.4 06/27/2005 08:00:00 2.9 0.5 4.2 1.5 2.9 0.4 4.2 1.5 2.6 0.5 3.8 1.5 45 13 56 255 19.5 0.1 20 19.4 06/27/2005 08:10:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2.2 0.5 3.4 0.7 34 12 21 255 19.7 0 20.3 19.4 06/27/2005 08:20:00 1.9 0.7 3.4 0.4 2 0.7 3.8 0.4 1.8 0.6 3.8 0.4 48 20 69 255 20 0 20.3 19.7 06/27/2005 08:30:00 2.1 0.5 3.4 1.1 2.1 0.5 3.8 1.1 2 0.5 3.4 0.7 46 12 34 255 19.7 0 20 19.4 06/27/2005 08:40:00 1.4 0.5 3 0.4 1.5 0.5 3 0.4 1.5 0.5 2.6 0.4 23 27 19 255 20.3 0.3 20.8 19.7 06/27/2005 08:50:00 1.9 0.6 3.4 0.4 1.9 0.6 3.8 0.4 1.6 0.7 3 0.4 4 14 345 255 20.8 0 21.1 20.8 06/27/2005 09:00:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 1.7 0.6 3 0.4 10 20 329 255 21.2 0 21.7 21.1 06/27/2005 09:10:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 1.5 0.5 3 0.4 23 21 18 255 21.3 0 21.4 21.1 06/27/2005 09:20:00 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 356 36 322 255 21.6 0.1 22.3 21.4 06/27/2005 09:30:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.6 0.7 3 0.4 358 19 16 255 21.8 0.1 22.6 21.7 06/27/2005 09:40:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.6 0.5 3.4 0.4 14 21 46 255 21.9 0.1 22.3 21.4 06/27/2005 09:50:00 1.7 0.5 3 0.4 1.7 0.5 3 0.4 1.5 0.5 3.4 0.4 30 22 64 255 22 0.2 22.6 21.7 06/27/2005 10:00:00 1.1 0.7 2.6 0.4 1 0.7 3 0.4 1.1 0.5 2.6 0.4 329 43 357 255 22.1 0 22.6 22 06/27/2005 10:10:00 1.3 1.1 4.2 0.4 1.2 1 3.8 0.4 1.1 1 3.8 0.4 40 64 40 255 22.7 0 22.9 22.6 06/27/2005 10:20:00 1.6 0.6 3.4 0.4 1.6 0.6 3 0.4 1.5 0.5 2.6 0.4 30 45 339 255 22.2 0.4 22.9 21.4 06/27/2005 10:30:00 2.8 0.6 4.6 1.1 2.8 0.7 4.6 0.7 2.3 0.7 4.2 0.4 0 20 13 255 22 0.4 22.6 21.1 06/27/2005 10:40:00 2.7 0.7 4.6 0.7 2.7 0.7 4.6 0.7 2.1 0.8 4.2 0.7 6 32 12 255 22.4 0.1 22.9 21.7 06/27/2005 10:50:00 3 0.6 4.6 1.9 2.9 0.6 4.6 1.9 2.3 0.8 4.2 0.4 15 19 37 255 21.1 0.2 22 20.8 06/27/2005 11:00:00 2.6 0.7 4.2 0.4 2.4 0.7 4.2 0.4 2.1 0.7 3.8 0.4 349 18 11 255 21 0 21.7 20.8 06/27/2005 11:10:00 1.8 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.1 0.6 3 0.4 350 16 17 255 21.3 0 21.4 21.1 06/27/2005 11:20:00 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.5 0.8 3.8 0.4 338 41 342 255 22.1 0.4 22.9 21.4 06/27/2005 11:30:00 2.6 0.7 4.2 1.1 2.4 0.6 4.2 1.1 2.2 0.7 4.2 0.4 332 30 352 255 23.1 0 23.8 22.9 06/27/2005 11:40:00 2.2 0.9 4.6 0.4 2 0.8 4.2 0.4 1.9 0.9 4.9 0.4 346 26 332 255 23.5 0 23.8 23.2 06/27/2005 11:50:00 2.4 0.6 3.8 1.1 2.3 0.6 3.8 0.7 2.1 0.8 3.8 0.4 340 33 332 255 23.4 0.1 23.8 22.9 06/27/2005 12:00:00 1.5 0.8 3.4 0.4 1.5 0.7 3 0.4 1.3 0.6 3 0.4 288 69 83 255 23.1 0.2 23.5 22.6 06/27/2005 12:10:00 2 0.7 3.8 0.7 2 0.7 3.8 0.7 1.6 0.8 3.8 0.4 17 20 38 255 22.3 0.1 22.9 22 06/27/2005 12:20:00 1.5 0.8 3.8 0.4 1.5 0.8 4.2 0.4 1.6 0.7 3.4 0.4 89 27 80 255 23.5 0.3 24.1 22.9 06/27/2005 12:30:00 1.7 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.9 0.7 4.2 0.4 26 79 92 255 24.1 0.2 24.7 23.8 06/27/2005 12:40:00 1.3 0.6 2.6 0.4 1.3 0.6 3 0.4 1.4 0.8 3.4 0.4 27 45 64 255 24.6 0.3 25.3 24.1 06/27/2005 12:50:00 1.3 0.6 3 0.4 1.3 0.6 2.6 0.4 1.4 0.6 3 0.4 106 29 89 255 24 0.4 25 23.5 06/27/2005 13:00:00 1.4 0.5 3 0.4 1.4 0.5 2.6 0.4 1.4 0.6 3 0.4 131 35 158 255 23.4 0 23.8 23.2 06/27/2005 13:10:00 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 84 20 83 255 22.8 0.1 23.5 22.6 06/27/2005 13:20:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.6 3 0.4 125 47 121 255 23.4 0.5 24.4 22.9 06/27/2005 13:30:00 1.6 1 3.8 0.4 1.6 1 4.2 0.4 1.5 0.9 3.4 0.4 54 90 65 255 24.8 0.2 25.3 24.1 06/27/2005 13:40:00 1.7 1.2 4.2 0.4 1.8 1.1 4.2 0.4 1.7 1 3.8 0.4 47 79 341 255 25.6 0.1 25.9 25.3 06/27/2005 13:50:00 0.9 0.6 2.3 0.4 1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 61 82 19 255 26 0.2 26.5 25.6 06/27/2005 14:00:00 2.3 0.8 4.6 0.4 2.3 0.8 4.2 0.4 2.1 0.7 3.8 0.7 27 26 25 255 26.2 0.1 26.5 25.9 06/27/2005 14:10:00 2.3 0.7 4.2 0.4 2.3 0.7 4.6 0.7 2.1 0.6 3.8 0.7 12 27 32 255 26.6 0.1 27.1 26.2 06/27/2005 14:20:00 2.7 1.1 4.9 0.4 2.7 1.1 5.3 0.4 2.4 0.9 4.9 0.7 3 20 15 255 26 0.3 26.8 25.3 06/27/2005 14:30:00 1.5 0.7 3 0.4 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 350 24 347 255 25.4 0.2 26.2 25.3 06/27/2005 14:40:00 1.9 1 4.2 0.4 1.9 0.9 3.8 0.4 1.9 0.8 4.2 0.4 257 94 333 255 25.9 0.4 26.5 25.3 06/27/2005 14:50:00 3.5 2 7.2 0.4 3.5 1.9 7.2 0.4 3.3 1.8 8.8 1.1 103 28 96 255 24.6 0.3 25.3 23.8 06/27/2005 15:00:00 4 1.2 7.6 1.1 4 1.2 6.8 1.1 3.6 1.2 6.5 1.5 112 22 93 255 23.2 0 23.8 22.9 06/27/2005 15:10:00 4.9 1.2 8 2.3 4.9 1.1 8 2.3 4.2 1.3 7.2 0.7 100 18 105 255 22.8 0.1 23.5 22.6 06/27/2005 15:20:00 3.7 1.1 6.8 1.1 3.7 1.1 6.8 1.5 3.2 1 6.1 1.1 111 22 94 255 21.9 0.3 22.6 21.4 06/27/2005 15:30:00 4 0.9 6.1 1.1 3.9 1 6.1 0.7 3.5 0.8 5.7 0.7 108 18 113 255 22.1 0.7 23.8 21.1 06/27/2005 15:40:00 4.2 0.9 6.1 1.5 4.2 0.8 6.1 1.9 3.7 0.9 5.7 1.5 106 17 111 255 23.8 0.1 24.4 23.5 06/27/2005 15:50:00 4 1 6.5 1.9 4 1 6.1 1.5 3.4 1.1 6.1 0.7 118 20 98 255 23.9 0.1 24.7 23.8 06/27/2005 16:00:00 3.1 1 5.3 0.4 3.1 1 4.9 0.4 2.7 1 4.9 0.7 136 30 114 255 24.6 0 25 24.4 06/27/2005 16:10:00 2.2 0.7 4.2 0.7 2.2 0.7 4.2 0.4 1.9 0.6 3.4 0.4 101 26 125 255 24.9 0.3 25.6 24.4 06/27/2005 16:20:00 3 0.6 4.6 1.5 3 0.6 4.6 1.1 2.7 0.6 4.2 1.1 82 35 42 255 25.3 0.2 25.6 25 06/27/2005 16:30:00 3.4 1.2 6.1 1.1 3.3 1.2 6.1 1.1 2.9 1.2 5.7 1.1 91 30 101 255 25.2 0 25.3 25.3 06/27/2005 16:40:00 2.3 1.2 4.9 0.4 2.3 1.2 4.9 0.4 2 1.1 4.9 0.4 79 35 139 255 25.3 0 25.6 25.3 06/27/2005 16:50:00 2.7 1.1 5.7 0.4 2.7 1.1 5.3 0.4 2.3 1.1 5.3 0.4 82 28 67 255 25.3 0 25.6 25.3 06/27/2005 17:00:00 2.5 0.9 5.3 0.4 2.6 0.9 5.3 0.4 2.5 0.8 4.6 0.4 90 29 87 255 25.3 0 25.6 25.3 06/27/2005 17:10:00 5.1 0.8 6.8 2.3 5.1 0.7 6.5 2.6 4.3 0.9 6.1 1.9 24 15 39 255 25.3 0 25.6 25.3 06/27/2005 17:20:00 5.1 0.6 6.5 3 5.1 0.6 6.5 3.4 4.1 0.9 6.1 1.9 15 10 42 255 25.2 0.1 25.6 25 06/27/2005 17:30:00 4.8 0.7 6.5 2.3 4.8 0.8 6.5 2.6 3.4 1 5.7 1.1 9 15 350 255 24.9 0 25.3 25 06/27/2005 17:40:00 5.6 1.2 8 1.5 5.5 1.2 8.4 0.7 4.4 1.4 7.2 1.1 20 14 18 255 24.7 0 25 24.7 06/27/2005 17:50:00 6.5 1 9.5 4.2 6.4 1 10.3 3.4 5.1 1.2 7.6 2.3 19 11 345 255 24.6 0 25 24.4 06/27/2005 18:00:00 5.1 0.9 7.6 2.6 5.1 1 7.6 2.3 4.6 1.1 7.2 2.3 29 15 34 255 24.4 0 24.7 24.4 06/27/2005 18:10:00 6 1.1 9.5 3 5.9 1.1 9.5 3 4.4 1.3 8 1.9 20 13 8 255 24.3 0 24.7 24.1 06/27/2005 18:20:00 5.5 1.1 8.4 2.3 5.4 1.1 8.4 2.6 4.4 1.4 8 1.1 21 15 31 255 23.8 0.2 24.1 23.5 06/27/2005 18:30:00 5.5 1 7.6 2.6 5.5 1 8 3 4 1.1 6.8 1.5 14 12 2 255 23.3 0.1 23.5 22.9 06/27/2005 18:40:00 5.8 1.2 8.4 2.6 5.7 1.3 8.4 2.3 4.5 1.6 8 0.7 18 13 27 255 22.7 0 23.2 22.6 06/27/2005 18:50:00 5 1.4 7.6 0.4 5 1.4 8 0.7 4.1 1.5 7.2 0.4 20 33 19 255 22.2 0 22.6 22 06/27/2005 19:00:00 4.9 1.4 9.5 1.9 4.9 1.4 9.5 2.3 3.8 1.5 8 1.1 18 16 18 255 22.2 0 22.6 22 06/27/2005 19:10:00 5.6 1.1 8.8 2.6 5.6 1.1 8.8 3 4.4 1.2 7.6 1.5 16 12 2 255 22.3 0 22.9 22.3 06/27/2005 19:20:00 5 1.3 8.4 2.3 4.9 1.3 8.8 1.5 3.5 1.5 6.8 0.7 12 15 18 255 21.9 0.1 22.3 21.7 06/27/2005 19:30:00 5 1.5 8.8 1.5 4.9 1.6 8.8 1.9 3.7 1.5 9.1 1.1 357 23 359 255 21.6 0 21.7 21.1 06/27/2005 19:40:00 3.9 1 6.5 0.7 3.6 0.9 6.1 0.7 2.7 1.1 5.7 0.4 350 17 346 255 21.2 0 21.4 21.1 06/27/2005 19:50:00 3.4 0.8 4.9 0.7 3.2 0.8 4.9 0.7 2.1 1 4.6 0.4 353 17 334 255 21.1 0 21.1 21.1 06/27/2005 20:00:00 3.5 0.6 5.3 1.9 3.5 0.6 5.3 2.3 2.6 0.7 4.2 0.4 19 14 24 255 21.3 0 21.7 21.1 06/27/2005 20:10:00 2.4 0.7 4.2 0.7 2.3 0.7 4.2 0.4 1.8 0.8 3.4 0.4 355 18 359 255 21.4 0 21.7 21.1 06/27/2005 20:20:00 2.2 0.6 3.8 0.7 2 0.6 3.8 0.7 1.5 0.7 3 0.4 352 17 329 255 21.4 0.1 22 21.1 06/27/2005 20:30:00 1.4 0.6 2.6 0.4 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 310 26 336 255 21 0.2 21.7 20.5 06/27/2005 20:40:00 2.6 1.7 6.1 0.4 2.6 1.7 6.5 0.4 2.1 1.3 5.7 0.4 45 24 30 255 20.2 0.3 21.1 19.4 06/27/2005 20:50:00 4.2 1 6.1 1.5 4.2 1 6.1 1.1 2.9 1 5.3 0.7 16 12 24 255 18.6 0.4 19.7 17.7 06/27/2005 21:00:00 2.9 0.6 4.2 1.5 2.9 0.6 4.2 1.5 2.2 0.6 3.8 0.7 38 14 25 255 17.4 0.2 18.2 16.8 06/27/2005 21:10:00 1.9 0.6 3.4 0.4 1.8 0.6 3.8 0.4 1.5 0.5 3 0.4 44 18 53 255 16.7 0.2 17.1 16.3 06/27/2005 21:20:00 1.8 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.3 0.5 2.6 0.4 64 16 60 255 16 0 16.3 16 06/27/2005 21:30:00 2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.4 0.6 3 0.4 43 12 45 255 15.7 0 16 15.7 06/27/2005 21:40:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 0.9 0.4 1.9 0.4 48 13 53 255 15.1 0.2 15.7 14.6 06/27/2005 21:50:00 2 0.3 2.6 1.1 2 0.3 3 1.1 1.3 0.4 2.3 0.7 60 4 57 255 14.4 0.1 14.9 14.1 06/27/2005 22:00:00 1.9 0.4 3 1.1 2 0.4 3.4 1.1 1.2 0.4 2.3 0.4 63 6 58 255 13.9 0 14.6 13.5 06/27/2005 22:10:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1 0.3 1.5 0.4 68 17 54 255 13.5 0 14.1 13.3 06/27/2005 22:20:00 1.8 0.4 2.6 1.1 1.8 0.4 2.6 1.1 1.2 0.3 2.3 0.4 104 6 110 255 13.3 0 13.8 13 06/27/2005 22:30:00 3 0.4 3.8 2.3 3 0.4 3.8 1.9 2.1 0.5 3.4 0.7 100 8 95 255 13.1 0 13.5 13 06/27/2005 22:40:00 2.4 0.8 4.2 0.4 2.4 0.8 4.2 0.7 1.6 0.6 3 0.4 110 16 91 255 13.1 0.2 13.8 12.7 06/27/2005 22:50:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.3 2.1 0.4 3.4 1.1 86 6 89 255 12.9 0.1 13.3 12.7 06/27/2005 23:00:00 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.9 1.8 0.5 3 0.4 101 11 93 255 12.7 0.1 13.3 12.2 06/27/2005 23:10:00 1.6 0.7 3 0.4 1.6 0.7 3 0.4 0.9 0.4 1.9 0.4 109 19 109 255 12.2 0 12.7 11.9 06/27/2005 23:20:00 2 0.5 3 0.7 2 0.6 3.4 0.7 1.2 0.7 2.6 0.4 131 11 136 255 11.9 0.1 12.5 11.7 06/27/2005 23:30:00 1.4 0.5 3 0.4 1.4 0.5 2.6 0.4 0.9 0.4 1.9 0.4 111 18 142 255 11.7 0 12.2 11.7 06/27/2005 23:40:00 1.8 0.4 2.6 0.4 1.8 0.4 2.6 0.7 1.3 0.4 2.3 0.4 118 10 113 255 11.7 0 12.2 11.7 06/27/2005 23:50:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1 0.4 1.9 0.4 136 11 147 255 11.5 0.1 11.9 11.1 06/28/2005 00:00:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 104 23 144 255 11.3 0 11.7 11.1 06/28/2005 00:10:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 77 5 80 255 11.1 0 11.7 10.9 06/28/2005 00:20:00 1.4 0.6 2.3 0.4 1.4 0.6 2.6 0.4 0.8 0.4 1.9 0.4 109 26 121 255 10.8 0.1 11.4 10.6 06/28/2005 00:30:00 2.6 0.6 3.4 0.7 2.6 0.6 3.4 0.7 1.9 0.5 3 0.4 149 7 152 255 10.6 0 11.1 10.6 06/28/2005 00:40:00 2.2 0.6 3.4 0.7 2.2 0.6 3.4 0.7 1.9 0.5 3 0.4 118 26 130 255 10.5 0 10.9 10.6 06/28/2005 00:50:00 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.9 2.1 0.8 3.4 0.4 143 6 133 255 10.3 0 10.9 10.3 06/28/2005 01:00:00 1.7 0.5 3.4 0.4 1.7 0.6 3.4 0.4 1.1 0.6 2.6 0.4 67 41 131 255 10.5 0 11.1 10.3 06/28/2005 01:10:00 2.2 0.5 3 1.1 2.2 0.5 3.4 1.1 1.3 0.6 2.6 0.4 51 9 47 255 10.5 0 11.1 10.3 06/28/2005 01:20:00 2.9 0.4 3.8 1.9 3 0.5 4.2 1.9 2 0.5 3.4 1.1 68 10 62 255 10.3 0 10.9 10.3 06/28/2005 01:30:00 3.8 0.4 4.9 2.3 3.8 0.4 4.9 2.6 2.6 0.5 3.8 1.1 82 7 71 255 10.2 0 10.6 10.1 06/28/2005 01:40:00 3.6 0.5 4.6 2.3 3.6 0.5 4.9 2.6 2.5 0.5 3.8 1.1 75 9 84 255 10.5 0 10.6 10.3 06/28/2005 01:50:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 2.4 0.5 3.8 1.1 77 7 76 255 10.6 0 10.6 10.6 06/28/2005 02:00:00 3.2 0.6 4.6 1.9 3.2 0.6 4.9 1.9 2.3 0.5 3.8 0.7 74 9 69 255 10.5 0 10.6 10.3 06/28/2005 02:10:00 3.2 0.6 4.6 1.5 3.2 0.6 4.6 1.5 2.2 0.5 3.4 1.1 71 9 73 255 10.5 0 10.6 10.3 06/28/2005 02:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 2.2 0.4 3 0.7 81 6 85 255 10.2 0 10.6 10.1 06/28/2005 02:30:00 2.7 0.6 3.8 1.1 2.7 0.6 4.2 1.1 1.8 0.4 2.6 0.7 95 10 91 255 9.8 0.1 10.1 9.6 06/28/2005 02:40:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.5 2.2 0.5 3 1.1 99 6 86 255 9.7 0 9.8 9.6 06/28/2005 02:50:00 3.5 0.4 4.2 2.3 3.5 0.4 4.2 2.6 2.5 0.4 3.4 1.5 93 5 91 255 10.2 0.2 10.6 9.8 06/28/2005 03:00:00 2.9 0.5 4.6 1.9 2.9 0.5 4.6 1.9 1.8 0.5 3.4 0.7 89 5 88 255 10.2 0 10.6 9.8 06/28/2005 03:10:00 2.4 0.4 3.4 1.1 2.4 0.4 3 1.1 1.6 0.4 2.6 0.4 94 5 88 255 10 0 10.1 9.8 06/28/2005 03:20:00 2.7 0.5 4.2 1.9 2.7 0.6 4.6 1.5 1.5 0.7 3 0.4 79 8 93 255 9.8 0 10.1 9.8 06/28/2005 03:30:00 2.3 0.5 3.8 1.5 2.3 0.5 3.8 1.1 1.5 0.4 2.6 0.7 67 9 53 255 9.7 0 9.8 9.6 06/28/2005 03:40:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.7 1.7 0.5 3 0.4 123 21 126 255 9.6 0 9.6 9.6 06/28/2005 03:50:00 1.7 0.6 3 0.4 1.7 0.5 3 0.4 1.1 0.7 2.6 0.4 155 11 138 255 9.5 0 9.6 9.3 06/28/2005 04:00:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.1 0.4 1.9 0.4 146 7 150 255 9.5 0 9.6 9.3 06/28/2005 04:10:00 1.9 0.4 2.6 1.1 1.9 0.4 2.6 0.7 1.2 0.4 1.9 0.4 127 15 124 255 9.4 0 9.6 9.3 06/28/2005 04:20:00 1.9 0.3 2.6 1.1 1.9 0.4 2.6 1.1 1.1 0.4 1.9 0.4 110 10 108 255 9.4 0 9.6 9.3 06/28/2005 04:30:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.7 0.3 2.3 0.7 90 8 86 255 9.6 0 9.8 9.6 06/28/2005 04:40:00 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.6 2.3 0.3 3.4 1.5 83 6 76 255 9.9 0.2 10.6 9.6 06/28/2005 04:50:00 3.7 0.5 4.9 2.6 3.7 0.5 5.3 2.3 2.5 0.5 4.2 1.1 79 6 77 255 11 0.3 11.7 10.6 06/28/2005 05:00:00 2 0.9 3.4 0.4 2.1 0.9 3.4 0.4 1.3 0.7 2.6 0.4 65 7 68 255 12.3 0.3 12.7 11.7 06/28/2005 05:10:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.5 0.4 107 24 119 255 12.7 0 13.3 12.5 06/28/2005 05:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 127 36 148 255 13.1 0 13.5 12.7 06/28/2005 05:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 58 4 63 255 13.5 0 14.1 13.3 06/28/2005 05:40:00 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.6 2.3 0.4 45 18 63 255 13.8 0.2 14.4 13.3 06/28/2005 05:50:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 42 10 55 255 14.7 0.5 16 13.8 06/28/2005 06:00:00 1.3 0.3 1.9 0.4 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 5 14 14 255 16.3 0.3 17.1 15.7 06/28/2005 06:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.6 3 0.4 46 11 42 255 16.6 0.1 16.8 16.3 06/28/2005 06:20:00 2.2 0.6 3.4 0.7 2.3 0.6 3.4 0.7 2 0.6 3.4 0.7 46 12 37 255 16.4 0.1 16.8 16 06/28/2005 06:30:00 1.4 0.5 2.3 0.4 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 41 21 11 255 16.6 0.3 17.1 16 06/28/2005 06:40:00 1.7 0.3 2.6 1.1 1.8 0.3 2.6 0.7 1.8 0.3 2.6 0.7 34 9 35 255 17.1 0 17.1 16.8 06/28/2005 06:50:00 1.7 0.6 2.6 0.4 1.7 0.6 2.6 0.4 1.5 0.6 2.6 0.4 11 15 17 255 17.4 0.1 18 17.1 06/28/2005 07:00:00 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 28 15 9 255 18 0 18.2 17.7 06/28/2005 07:10:00 2.5 0.6 3.8 1.1 2.6 0.6 3.8 0.7 2.2 0.6 3.8 0.7 48 15 63 255 17.8 0 18.2 17.7 06/28/2005 07:20:00 2.2 0.5 3.4 0.4 2.2 0.5 3.4 0.4 2 0.6 3 0.4 46 17 28 255 17.8 0 18 17.7 06/28/2005 07:30:00 1.6 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.5 0.7 3 0.4 20 14 12 255 17.9 0 18.5 17.7 06/28/2005 07:40:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 31 22 21 255 18.4 0.2 19.1 17.7 06/28/2005 07:50:00 1.8 0.5 3 0.7 1.8 0.5 3.4 0.4 1.5 0.5 2.3 0.4 24 19 12 255 19 0.1 19.4 18.5 06/28/2005 08:00:00 0.9 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 2.3 0.4 30 43 61 255 18.7 0.3 19.4 18 06/28/2005 08:10:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 341 19 337 255 17.7 0.4 18.2 16.8 06/28/2005 08:20:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.6 0.6 3 0.4 336 9 328 255 16.4 0.3 17.4 16 06/28/2005 08:30:00 1.4 0.4 2.6 0.4 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 338 18 343 255 16.4 0.2 17.1 16 06/28/2005 08:40:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 349 19 325 255 17 0.3 17.7 16.6 06/28/2005 08:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 352 13 358 255 17.4 0.1 18 17.1 06/28/2005 09:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 345 8 358 255 17.5 0.3 18.5 16.8 06/28/2005 09:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 355 23 21 255 18.2 0.2 18.8 18 06/28/2005 09:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 41 36 55 255 19.4 0.4 20.5 18.5 06/28/2005 09:30:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 41 30 359 255 20.8 0.2 21.4 20.3 06/28/2005 09:40:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 19 33 31 255 21.3 0 21.7 21.1 06/28/2005 09:50:00 0.9 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.8 0.5 2.6 0.4 29 26 21 255 21.5 0 21.7 21.1 06/28/2005 10:00:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.6 3 0.4 351 61 358 255 22.3 0.2 23.2 21.7 06/28/2005 10:10:00 1 0.7 3 0.4 1 0.8 3 0.4 1 0.6 3 0.4 23 39 353 255 22.7 0 23.5 22.6 06/28/2005 10:20:00 1.7 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.4 0.6 3 0.4 12 22 14 255 23 0.1 23.8 22.6 06/28/2005 10:30:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.6 0.6 3 0.4 3 23 4 255 23.6 0 23.8 23.5 06/28/2005 10:40:00 1.6 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.5 0.8 3.4 0.4 17 29 63 255 23.8 0 24.1 23.8 06/28/2005 10:50:00 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.6 2.6 0.4 271 61 22 255 23.6 0 24.1 23.5 06/28/2005 11:00:00 1.5 0.6 3 0.4 1.5 0.7 3 0.4 1.4 0.7 3 0.4 342 30 315 255 24.4 0.3 25 23.8 06/28/2005 11:10:00 1.7 1 4.9 0.4 1.6 1 4.6 0.4 1.2 0.6 3.4 0.4 309 53 35 255 24.6 0.1 25 24.4 06/28/2005 11:20:00 1.2 0.7 3.4 0.4 1.1 0.7 3 0.4 1.2 0.6 3 0.4 49 69 14 255 25 0 25.3 25 06/28/2005 11:30:00 1.4 1 4.2 0.4 1.4 1 4.2 0.4 1.4 1 3.8 0.4 207 69 227 255 25.1 0.1 25.6 25 06/28/2005 11:40:00 2.9 1 5.7 1.1 2.7 1 4.9 1.1 2.4 1 4.9 0.7 312 43 341 255 25.7 0 25.9 25.3 06/28/2005 11:50:00 1.9 0.9 3.8 0.4 1.9 0.8 4.2 0.4 1.5 0.7 3.4 0.4 8 82 20 255 25.9 0 26.2 25.9 06/28/2005 12:00:00 2 1 4.6 0.4 1.9 1.1 4.6 0.4 1.6 1 4.6 0.4 303 79 294 255 25.9 0 26.2 25.6 06/28/2005 12:10:00 2.8 1.2 6.1 0.4 2.8 1.3 6.1 0.4 2.7 1.3 6.1 0.4 105 36 109 255 25.7 0.1 26.2 25.6 06/28/2005 12:20:00 3.3 1.9 10.3 0.4 3.4 1.9 9.9 0.4 2.9 1.6 9.5 0.4 72 47 149 255 26 0 26.2 25.6 06/28/2005 12:30:00 3.6 1.8 8.4 0.7 3.5 1.8 8 0.7 2.9 1.7 8.8 0.4 47 51 108 255 25.4 0.2 25.9 25 06/28/2005 12:40:00 4.7 1.5 8.8 1.9 4.7 1.4 8.8 1.9 4.1 1.4 8.4 1.9 83 24 99 255 25.4 0 25.9 25.3 06/28/2005 12:50:00 6.6 1.5 10.7 3 6.5 1.5 9.9 2.6 5.4 1.6 9.1 1.9 88 20 67 255 26.6 0.3 27.1 25.6 06/28/2005 13:00:00 5.3 1.3 9.1 2.3 5.3 1.3 8.8 1.9 4.4 1.2 7.6 1.5 87 22 107 255 26.7 0.2 27.1 26.5 06/28/2005 13:10:00 5.2 1.5 8.4 1.5 5.1 1.5 8.4 1.1 4.4 1.5 8.8 0.7 94 24 110 255 26.6 0.4 27.1 26.2 06/28/2005 13:20:00 5.1 1.4 10.3 1.5 5.2 1.3 10.3 2.3 4.2 1.3 8.4 0.7 86 23 78 255 26.6 0.2 27.1 26.2 06/28/2005 13:30:00 6.4 1.5 10.7 1.5 6.3 1.5 10.7 1.9 5.5 1.4 8.8 2.6 85 20 72 255 27.4 0 27.7 27.1 06/28/2005 13:40:00 6.1 1.7 10.7 2.3 6.2 1.6 10.7 2.3 5.2 1.6 9.9 1.1 77 22 47 255 27.8 0 28 27.4 06/28/2005 13:50:00 5.2 1.3 9.5 2.3 5.2 1.4 9.1 2.3 4.5 1.3 8 1.9 78 26 68 255 27.2 0.1 27.7 26.5 06/28/2005 14:00:00 4.8 1.9 9.1 0.4 4.8 2 8.8 0.4 3.9 1.8 8 0.4 29 38 93 255 26.8 0.3 27.7 26.5 06/28/2005 14:10:00 6.2 1.5 10.7 3 6.2 1.5 10.3 2.6 5.1 1.6 10.7 1.1 79 24 101 255 28 0.2 28.3 27.4 06/28/2005 14:20:00 6.2 1.8 10.7 2.3 6.2 1.8 10.7 2.6 5.3 1.8 10.3 1.9 79 19 72 255 27.1 0.5 28.3 26.5 06/28/2005 14:30:00 5.2 1.7 9.1 1.1 5.3 1.7 9.1 1.9 4.6 1.7 8.8 0.4 90 22 98 255 27.6 0.4 28.3 26.8 06/28/2005 14:40:00 6.5 1.7 11.1 2.6 6.5 1.7 10.7 2.6 5.5 1.7 10.3 1.5 93 15 82 255 25.8 0.7 27.4 25 06/28/2005 14:50:00 4.7 1.3 7.6 1.5 4.7 1.2 7.6 1.5 4.1 1.1 6.5 0.7 96 17 74 255 26.3 0.6 27.1 25.3 06/28/2005 15:00:00 4.9 1.5 8.4 1.1 4.9 1.4 8.4 1.5 4.1 1.5 7.6 0.4 85 22 104 255 27.3 0.1 27.7 27.1 06/28/2005 15:10:00 5 1.6 9.1 1.1 5 1.7 9.9 1.5 4.2 1.5 9.1 1.5 86 24 105 255 27 0.3 27.7 26.5 06/28/2005 15:20:00 6.3 1.7 10.7 1.9 6.3 1.7 10.7 1.9 5.5 1.7 11.1 1.9 78 17 87 255 26.6 0.4 27.4 26.2 06/28/2005 15:30:00 7.4 1.9 12.6 3.8 7.4 1.9 13 3.4 6.5 1.9 11.5 2.3 81 20 95 255 27.3 0.1 27.4 26.8 06/28/2005 15:40:00 6.6 1.7 10.7 1.9 6.5 1.8 10.7 0.4 5.4 1.8 10.3 1.5 94 22 105 255 27.2 0.2 27.4 26.5 06/28/2005 15:50:00 5.7 1.5 9.5 1.1 5.7 1.3 9.9 2.3 4.8 1.3 8.4 1.9 106 22 113 255 25.7 0.1 26.5 25.3 06/28/2005 16:00:00 5.4 1.5 9.1 2.6 5.4 1.5 9.1 1.9 4.7 1.5 8 1.5 109 17 100 255 24.7 0.4 25.9 23.8 06/28/2005 16:10:00 4.4 1.1 7.2 1.9 4.4 1.1 6.8 1.5 3.8 1 6.1 1.5 106 21 96 255 23.6 0.1 24.1 23.5 06/28/2005 16:20:00 5.3 1.1 8.4 2.3 5.3 1.1 8.4 2.3 4.6 1.1 8 2.3 105 17 105 255 23.1 0.2 23.5 22.9 06/28/2005 16:30:00 4.8 1 7.6 1.9 4.8 1 8 1.1 4.1 1 7.2 1.1 99 18 94 255 22.7 0 22.9 22.9 06/28/2005 16:40:00 4.6 1 8 2.3 4.6 1 7.6 2.6 3.8 0.9 7.2 1.9 100 17 105 255 23.1 0.2 23.5 22.9 06/28/2005 16:50:00 4.7 1 7.2 2.3 4.6 1 7.2 2.3 4.2 0.9 6.5 1.9 100 16 120 255 24 0.2 24.4 23.5 06/28/2005 17:00:00 6 1.3 10.3 2.6 6 1.3 9.9 3.4 5.2 1.5 11.1 1.9 105 15 97 255 24.4 0 24.7 24.4 06/28/2005 17:10:00 5.5 1.3 8.8 1.9 5.5 1.3 8.4 1.9 4.6 1.3 8.8 0.4 90 18 110 255 25.1 0.2 25.9 24.7 06/28/2005 17:20:00 3.5 1.1 6.5 0.7 3.6 1.1 6.8 0.4 3.1 1.1 6.5 0.4 61 27 71 255 26 0.2 26.8 25.6 06/28/2005 17:30:00 2.3 0.6 3.8 0.4 2.3 0.6 3.8 0.7 2 0.7 3.4 0.4 62 28 40 255 26.6 0 27.1 26.5 06/28/2005 17:40:00 6 2.3 11.1 2.3 6 2.2 11.1 2.3 5 2 9.9 2.3 92 20 94 255 25.7 0.7 26.8 24.7 06/28/2005 17:50:00 7 2 12.6 2.3 6.9 1.9 12.6 1.5 5.8 1.8 10.7 1.9 83 22 88 255 22.9 0.9 24.7 21.7 06/28/2005 18:00:00 5.3 1.4 8.8 1.9 5.3 1.3 8.8 2.3 4.5 1.5 8.8 1.1 92 20 81 255 21.6 0 21.7 21.7 06/28/2005 18:10:00 7 2 11.5 2.6 7 1.9 11.5 3 5.8 1.9 11.5 1.9 94 20 92 255 21.8 0 22.3 21.7 06/28/2005 18:20:00 4.5 1.5 8.4 1.1 4.5 1.4 8.4 1.1 3.7 1.2 6.8 1.5 87 21 93 255 22.2 0 22.9 22 06/28/2005 18:30:00 3.7 0.9 6.1 1.9 3.8 0.9 6.1 1.9 3 0.8 5.7 1.5 71 22 54 255 22.7 0.2 23.5 22.3 06/28/2005 18:40:00 2.8 0.8 4.6 1.1 2.8 0.8 4.6 0.7 2.2 0.8 4.6 0.4 96 23 89 255 22.7 0 23.5 22.3 06/28/2005 18:50:00 3.3 0.8 5.3 1.5 3.3 0.7 5.3 1.5 2.7 0.8 5.3 1.1 108 19 95 255 22.3 0 22.9 22 06/28/2005 19:00:00 5 1.3 8.4 1.9 5.1 1.3 8.4 1.9 4.3 1.4 7.2 1.1 101 18 90 255 22.1 0.1 22.6 21.7 06/28/2005 19:10:00 6.5 1.8 11.1 2.3 6.5 1.9 11.1 2.6 5.5 1.5 10.3 1.5 100 19 90 255 21.9 0.1 22.6 21.7 06/28/2005 19:20:00 5.6 1.2 9.1 1.9 5.6 1.2 8.8 1.9 4.6 1.3 8.8 0.7 104 15 102 255 21.9 0.1 22.3 21.7 06/28/2005 19:30:00 4.2 1.1 6.8 0.4 4.3 1.1 6.8 1.5 3.4 1.2 6.1 0.4 92 21 80 255 21.7 0.1 22.3 21.7 06/28/2005 19:40:00 6.3 1.3 9.5 2.3 6.2 1.3 9.5 3 5.2 1.3 8.8 2.3 109 18 111 255 21.8 0.1 22.3 21.7 06/28/2005 19:50:00 5.3 1.3 8.4 2.3 5.3 1.3 8.8 2.6 4.4 1.2 8 1.9 100 19 78 255 21.5 0.1 22.3 21.1 06/28/2005 20:00:00 6.7 1.7 11.5 1.9 6.7 1.7 11.5 2.6 5.5 1.7 9.9 0.7 98 18 97 255 21 0 21.7 20.8 06/28/2005 20:10:00 8 1.9 11.8 3.8 7.9 1.9 11.8 3 6.7 1.9 11.8 3 96 16 111 255 20.7 0 21.1 20.5 06/28/2005 20:20:00 5.3 1.3 9.9 2.6 5.4 1.3 9.1 2.6 4.5 1.3 8 1.5 92 17 84 255 20.5 0 20.8 20.5 06/28/2005 20:30:00 4.1 1.1 7.2 1.9 4.1 1.2 7.2 1.5 3.2 1 6.8 0.7 76 24 78 255 20.5 0 20.8 20.5 06/28/2005 20:40:00 3.2 0.9 5.3 1.5 3.1 0.9 5.3 1.1 2.5 0.8 4.6 0.7 85 15 78 255 20.3 0 20.5 20.3 06/28/2005 20:50:00 2.8 0.7 4.9 1.5 2.8 0.7 4.9 1.1 2 0.7 4.2 0.7 82 13 98 255 20.1 0 20.3 20 06/28/2005 21:00:00 3.3 1 6.5 0.7 3.3 1 6.1 0.7 2.7 0.9 5.7 0.7 70 21 91 255 20 0 20.3 20 06/28/2005 21:10:00 4.2 0.8 8 2.3 4.2 0.9 7.6 1.9 3.6 1 7.2 1.1 59 15 68 255 20 0 20.3 20 06/28/2005 21:20:00 4.2 1 6.8 1.9 4.2 1 7.2 1.5 3.2 1.1 7.2 0.7 60 20 43 255 19.9 0 20.3 19.7 06/28/2005 21:30:00 3.4 0.7 5.3 1.5 3.4 0.7 5.3 1.5 2.9 0.9 6.1 1.1 45 22 70 255 19.5 0 20 19.4 06/28/2005 21:40:00 4.2 1.3 7.2 1.1 4.1 1.4 7.2 1.1 3.3 1.3 6.8 0.7 40 17 59 255 19.1 0 19.4 18.8 06/28/2005 21:50:00 5.1 1.2 8.4 2.6 5.1 1.2 8.8 2.3 4 1.3 8 1.1 61 16 51 255 19.1 0 19.4 18.8 06/28/2005 22:00:00 4.2 1.3 8.8 1.1 4.2 1.2 8 1.5 3.5 1.2 8.4 1.1 88 13 92 255 19 0 19.4 18.5 06/28/2005 22:10:00 4.4 0.9 6.8 2.3 4.4 0.9 6.5 2.3 3.5 0.8 5.3 1.5 92 15 65 255 18.7 0 18.8 18.5 06/28/2005 22:20:00 4.6 0.8 6.8 2.6 4.6 0.8 6.8 2.6 3.5 0.8 5.7 1.9 102 15 90 255 19 0 19.1 18.5 06/28/2005 22:30:00 4.6 1 6.8 2.3 4.5 0.9 6.8 2.3 3.8 0.9 5.7 1.5 117 15 118 255 18.9 0 19.1 18.8 06/28/2005 22:40:00 4.1 0.9 6.8 1.9 4 0.9 6.1 1.9 3.2 0.8 5.7 1.1 115 15 129 255 18.6 0.1 18.8 18.2 06/28/2005 22:50:00 3.6 0.9 6.1 1.5 3.5 1 5.7 1.1 2.7 0.8 4.6 0.7 102 15 106 255 18.2 0 18.5 18 06/28/2005 23:00:00 3.1 0.8 4.9 0.7 2.9 0.8 4.9 0.7 2.3 0.7 4.6 1.1 94 15 97 255 17.9 0 18.2 17.7 06/28/2005 23:10:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.1 1.7 0.7 3.4 0.4 25 23 23 255 17.5 0.2 18 16.8 06/28/2005 23:20:00 2.4 0.5 3.8 1.1 2.2 0.6 3.8 0.4 1.6 0.5 2.6 0.4 76 11 73 255 16.4 0.3 17.1 15.7 06/28/2005 23:30:00 2.7 0.6 4.6 1.1 2.6 0.7 4.6 1.1 2 0.6 4.6 0.4 75 17 80 255 15.8 0 16.3 15.7 06/28/2005 23:40:00 4.6 1.3 8.8 2.6 4.6 1.3 8.4 2.3 3.6 1.1 7.2 1.5 66 15 69 255 15.8 0 16.3 15.7 06/28/2005 23:50:00 5 1.2 8 1.5 5 1.3 8 1.5 4.1 1.3 8 1.5 71 17 56 255 16.6 0.2 17.1 16 06/29/2005 00:00:00 4.1 0.8 6.5 1.9 4 0.8 6.5 1.9 3.1 1 5.3 0.7 76 15 80 255 16.6 0.2 17.1 16.3 06/29/2005 00:10:00 3.9 0.6 5.3 2.3 3.9 0.7 6.1 2.3 2.9 0.8 4.9 0.7 83 15 57 255 16.1 0.1 16.8 15.7 06/29/2005 00:20:00 3.2 0.7 5.3 1.5 3.2 0.7 5.3 1.5 2.5 0.8 4.6 0.4 91 15 81 255 15.7 0.2 16.3 15.2 06/29/2005 00:30:00 3.5 0.7 5.3 1.9 3.5 0.8 5.3 1.5 2.5 0.7 4.2 0.7 83 12 79 255 15.1 0 15.7 14.9 06/29/2005 00:40:00 3.7 0.6 4.9 2.3 3.7 0.7 5.3 2.3 2.8 0.6 4.6 1.5 83 10 71 255 15.2 0.1 15.7 15.2 06/29/2005 00:50:00 3.6 0.7 4.9 1.9 3.6 0.8 4.9 1.5 2.6 0.8 4.9 0.4 74 13 80 255 15.4 0 16 15.2 06/29/2005 01:00:00 1.7 0.9 4.2 0.4 1.4 1 4.2 0.4 1.2 0.8 3.4 0.4 74 12 73 255 15.4 0.2 16 15.2 06/29/2005 01:10:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 92 18 70 255 14.7 0.1 15.5 14.4 06/29/2005 01:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 97 22 191 255 14.2 0 14.6 14.1 06/29/2005 01:30:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 0.9 0.5 2.3 0.4 207 10 216 255 14.1 0.1 14.6 13.8 06/29/2005 01:40:00 1 0.4 1.9 0.4 1 0.5 1.5 0.4 0.8 0.4 1.5 0.4 180 7 185 255 13.8 0 14.4 13.5 06/29/2005 01:50:00 1.6 0.4 2.6 0.7 1.9 0.3 2.6 1.1 1.5 0.4 2.3 0.4 171 6 170 255 13.5 0 14.1 13.3 06/29/2005 02:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.1 0.4 99 39 158 255 13.2 0.1 13.8 12.7 06/29/2005 02:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 62 6 67 255 12.7 0.1 13.3 12.5 06/29/2005 02:20:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.4 0.2 1.1 0.4 119 24 126 255 12.3 0 12.5 12.2 06/29/2005 02:30:00 2.1 0.4 3 1.1 1.9 0.4 2.6 1.1 1.3 0.5 2.3 0.4 98 17 101 255 12.3 0.1 12.7 12.2 06/29/2005 02:40:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 65 1 65 255 12.5 0 12.7 12.5 06/29/2005 02:50:00 1.3 0.3 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 88 15 101 255 12.3 0 12.5 12.2 06/29/2005 03:00:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 0.9 0.5 2.3 0.4 114 15 115 255 12.3 0 12.5 12.2 06/29/2005 03:10:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.3 1.5 0.4 128 12 134 255 12.1 0 12.5 11.9 06/29/2005 03:20:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.6 0.3 1.5 0.4 110 9 100 255 11.8 0.1 12.2 11.7 06/29/2005 03:30:00 1.6 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1 0.4 1.9 0.4 125 8 119 255 11.7 0 12.2 11.7 06/29/2005 03:40:00 2.7 0.6 4.2 1.5 2.7 0.6 4.2 1.1 2.1 0.5 3.4 1.1 127 9 139 255 11.5 0 11.7 11.4 06/29/2005 03:50:00 3.3 0.5 4.2 2.3 3.4 0.5 4.6 1.9 2.7 0.4 4.2 1.5 126 9 141 255 11.9 0.2 12.7 11.4 06/29/2005 04:00:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.5 2.7 0.4 4.2 1.9 125 8 116 255 12.5 0 12.7 12.2 06/29/2005 04:10:00 2.8 0.5 3.8 1.1 2.8 0.5 3.8 1.1 2.4 0.5 3.8 1.1 128 10 119 255 12.8 0 13 12.7 06/29/2005 04:20:00 2.9 0.5 4.2 1.5 2.9 0.5 3.8 1.9 2.2 0.5 3.8 1.1 124 12 136 255 12.8 0 13 12.7 06/29/2005 04:30:00 2.7 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2 0.4 3.4 0.7 122 10 112 255 12.7 0 13 12.7 06/29/2005 04:40:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.2 0.4 3.4 0.7 126 9 122 255 13.1 0.1 13.8 12.7 06/29/2005 04:50:00 2.3 0.5 3.8 1.1 2.3 0.5 3.4 1.1 2 0.4 3 0.7 125 10 142 255 13.5 0.1 14.1 13.3 06/29/2005 05:00:00 2.4 0.5 3.4 1.1 2.4 0.5 3.8 1.1 2.1 0.5 3.4 0.7 131 10 130 255 14 0.1 14.4 13.8 06/29/2005 05:10:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.1 2.3 0.4 3.4 1.5 133 12 136 255 14.6 0 14.9 14.4 06/29/2005 05:20:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.1 2.2 0.5 3.4 1.1 132 12 127 255 14.8 0 15.5 14.9 06/29/2005 05:30:00 1.9 0.5 3 0.7 1.8 0.6 3 0.4 1.6 0.5 2.6 0.4 136 16 150 255 15.2 0.1 16 14.9 06/29/2005 05:40:00 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 122 28 94 255 15.7 0.2 16.6 15.5 06/29/2005 05:50:00 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 99 13 104 255 16.4 0.2 17.1 16.3 06/29/2005 06:00:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 77 16 115 255 17.3 0.2 17.7 16.8 06/29/2005 06:10:00 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 68 17 88 255 18.1 0.1 18.5 17.7 06/29/2005 06:20:00 1.7 0.4 3 0.7 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 35 15 51 255 18 0 18.5 17.7 06/29/2005 06:30:00 1.5 0.4 2.6 0.4 1.4 0.4 2.6 0.4 1.4 0.5 2.6 0.4 54 12 63 255 18.1 0 18.2 18 06/29/2005 06:40:00 1.7 0.4 2.6 0.4 1.7 0.5 3 0.4 1.6 0.5 3 0.4 73 17 70 255 18.3 0 18.5 18 06/29/2005 06:50:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.5 2.6 0.4 77 19 68 255 18.3 0 18.8 18.2 06/29/2005 07:00:00 1.8 0.5 3 0.4 1.7 0.5 3 0.4 1.7 0.6 3 0.4 80 11 70 255 18.5 0.1 19.1 18.2 06/29/2005 07:10:00 1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 1 0.5 1.9 0.4 84 21 80 255 18.9 0.2 19.4 18.5 06/29/2005 07:20:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.4 0.5 2.6 0.4 64 21 104 255 19.4 0.1 20 19.1 06/29/2005 07:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.4 2.6 0.4 75 16 58 255 19.7 0.1 20.3 19.4 06/29/2005 07:40:00 1.7 0.4 3 0.7 1.7 0.4 2.6 1.1 1.6 0.4 2.6 0.4 37 26 34 255 20 0 20.5 20 06/29/2005 07:50:00 1.7 0.4 3 0.7 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 9 13 11 255 20.5 0 20.8 20.3 06/29/2005 08:00:00 2 0.4 3.4 0.7 1.8 0.5 3.4 0.4 1.6 0.5 3 0.4 355 14 341 255 20.8 0 21.4 20.5 06/29/2005 08:10:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.4 0.5 2.6 0.4 21 13 30 255 20.9 0 21.1 20.8 06/29/2005 08:20:00 1.7 0.5 2.6 0.4 1.6 0.5 3 0.4 1.4 0.6 3 0.4 4 19 12 255 21.1 0 21.7 21.1 06/29/2005 08:30:00 2.1 0.5 3 0.7 2 0.5 3 0.4 1.9 0.6 3.4 0.4 5 12 6 255 21.6 0 22 21.1 06/29/2005 08:40:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 2 15 346 255 21.6 0 22 21.4 06/29/2005 08:50:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.5 2.6 0.4 346 26 6 255 21.7 0 22 21.4 06/29/2005 09:00:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 354 22 1 255 21.6 0 22 21.4 06/29/2005 09:10:00 1.5 0.6 2.6 0.4 1.3 0.5 2.6 0.4 1.4 0.6 3 0.4 351 23 358 255 21.6 0 22 21.4 06/29/2005 09:20:00 1.4 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.1 0.6 2.6 0.4 344 38 276 255 22.1 0.2 22.6 21.7 06/29/2005 09:30:00 2.6 0.7 4.2 1.1 2.5 0.7 4.2 0.7 2.2 0.8 4.6 0.4 307 20 313 255 22.1 0.1 22.6 21.7 06/29/2005 09:40:00 2.6 0.9 4.9 0.7 2.5 1 4.9 0.7 2.3 0.9 4.9 0.7 299 27 294 255 21.8 0.2 22.6 21.4 06/29/2005 09:50:00 2.8 0.9 5.3 1.1 2.6 0.9 5.3 1.1 2.2 0.7 5.3 0.7 315 23 267 255 22.4 0.4 23.5 22 06/29/2005 10:00:00 3.1 0.9 6.1 0.7 2.9 1 5.7 0.7 2.5 0.9 5.3 0.7 312 23 273 255 22.9 0.1 23.5 22.6 06/29/2005 10:10:00 2.9 1 5.7 0.7 2.8 1 4.9 0.4 2.5 1 5.7 0.4 273 30 279 255 22.8 0.1 23.5 22.6 06/29/2005 10:20:00 2.4 0.8 4.2 0.7 2.3 0.8 4.2 0.4 2.1 0.9 4.6 0.4 296 27 289 255 23 0.1 23.5 22.9 06/29/2005 10:30:00 2.1 1.1 4.9 0.4 2 1 4.6 0.4 1.7 1 4.9 0.4 273 58 298 255 23.5 0.2 23.8 22.9 06/29/2005 10:40:00 3.3 0.8 5.7 1.5 3.2 0.8 5.3 1.1 2.7 1 6.1 0.4 307 21 329 255 23.7 0.1 24.1 23.5 06/29/2005 10:50:00 2.9 1.1 5.7 0.7 3 1.1 5.7 0.7 2.4 1 4.9 0.4 239 27 254 255 23.5 0.4 24.1 22.9 06/29/2005 11:00:00 2.6 1.1 5.3 0.4 2.6 1.1 5.7 0.4 2.2 1 6.1 0.4 254 32 240 255 23.1 0 23.5 22.9 06/29/2005 11:10:00 2.1 1.2 5.3 0.4 2 1.2 4.9 0.4 1.8 1 4.9 0.4 263 43 280 255 23.3 0.1 23.5 22.9 06/29/2005 11:20:00 3.4 1.1 6.8 1.1 3.3 1.2 6.1 1.1 2.9 1.1 5.7 0.7 287 30 317 255 23.5 0 23.8 23.5 06/29/2005 11:30:00 2.5 1 5.7 0.4 2.5 1 5.3 0.4 2.1 0.9 4.6 0.4 290 39 303 255 23.9 0.2 24.4 23.5 06/29/2005 11:40:00 3.3 1.2 5.7 0.4 3.2 1.2 5.7 0.4 2.7 1.2 5.3 0.4 286 27 295 255 24.1 0.2 24.7 23.5 06/29/2005 11:50:00 3.3 1.2 6.1 0.4 3.3 1.2 5.7 0.4 2.8 1 6.1 0.4 265 22 259 255 23.6 0 24.1 23.5 06/29/2005 12:00:00 3 1.1 6.5 0.4 3 1.2 6.5 0.4 2.1 1.1 5.3 0.4 260 39 201 255 23.8 0 24.4 23.5 06/29/2005 12:10:00 3.5 1.2 6.1 0.4 3.5 1.3 6.1 0.4 3 1.3 6.1 0.7 277 29 292 255 23.5 0.6 24.4 22.9 06/29/2005 12:20:00 2.8 1.2 5.7 0.4 2.8 1.2 5.7 0.4 2.5 1.1 6.1 0.4 287 32 255 255 23.7 0.3 24.4 22.9 06/29/2005 12:30:00 3.6 1.2 6.5 0.4 3.5 1.2 5.7 0.4 3.1 1.1 6.5 0.7 276 38 308 255 24.2 0 24.4 24.1 06/29/2005 12:40:00 3.3 1.2 6.5 1.1 3.2 1.3 6.5 0.7 2.8 1 5.7 0.7 295 27 299 255 24.4 0.2 25 24.1 06/29/2005 12:50:00 2.8 0.9 4.9 0.4 2.8 1 5.3 0.4 2.4 1 4.9 0.4 288 22 296 255 24.1 0.1 24.7 23.8 06/29/2005 13:00:00 3 1.5 6.1 0.4 3 1.5 6.5 0.4 2.5 1.6 6.5 0.4 278 43 296 255 24.7 0.3 25.3 24.4 06/29/2005 13:10:00 3.9 1.2 6.8 1.5 3.9 1.2 6.5 1.5 3.6 1 6.5 1.5 294 23 305 255 24.4 0 25 24.4 06/29/2005 13:20:00 3.4 1.5 6.8 0.4 3.3 1.6 6.5 0.4 2.9 1.5 6.8 0.4 294 30 274 255 24.7 0 25 24.4 06/29/2005 13:30:00 2.8 1 5.3 0.4 2.6 1 4.9 0.4 2.4 1.1 5.3 0.4 319 51 309 255 24.8 0 25 24.7 06/29/2005 13:40:00 3.1 1 6.8 0.4 2.9 1.1 6.8 0.4 2.2 1.1 4.9 0.4 327 36 3 255 25.5 0.2 25.9 25 06/29/2005 13:50:00 2.3 1.1 4.9 0.4 2.2 1.1 4.9 0.4 1.8 1 4.9 0.4 266 43 302 255 26 0.2 26.5 25.6 06/29/2005 14:00:00 2.9 0.9 6.1 0.7 2.8 0.9 5.3 0.4 2.2 0.9 5.3 0.4 304 47 312 255 26.2 0.2 26.5 25.6 06/29/2005 14:10:00 3.7 1.1 6.1 0.7 3.6 1.1 6.5 0.4 2.9 1 5.7 0.7 314 22 289 255 24.9 0.3 25.6 24.4 06/29/2005 14:20:00 3.2 0.8 5.3 1.5 3 0.9 5.3 1.1 2.7 0.8 4.6 0.7 303 18 301 255 24.1 0.1 24.7 23.8 06/29/2005 14:30:00 3.3 1 5.7 0.4 3.2 1.1 5.7 0.4 2.6 1 5.3 0.4 305 20 300 255 24.1 0.2 24.7 23.8 06/29/2005 14:40:00 3.5 0.9 5.7 1.5 3.3 0.9 5.3 1.5 2.8 0.8 5.3 1.1 315 17 323 255 23.7 0 23.8 23.5 06/29/2005 14:50:00 3.2 1 6.1 0.7 3.2 1 6.1 0.7 2.6 1.2 6.1 0.4 312 17 298 255 23.9 0.2 24.4 23.5 06/29/2005 15:00:00 3.1 1.1 5.3 0.4 3 1.1 5.3 0.4 2.6 1.1 6.1 0.4 290 35 322 255 24.5 0.5 25.3 23.8 06/29/2005 15:10:00 4.1 1.1 6.5 0.7 4.1 1.1 6.1 0.4 3.5 1.2 5.7 0.4 297 17 294 255 25 0 25.3 25 06/29/2005 15:20:00 3.4 1.1 6.5 0.7 3.3 1.1 6.1 0.4 2.9 1.2 5.7 0.7 297 26 303 255 25.3 0 25.6 25 06/29/2005 15:30:00 3.7 1.1 6.8 1.1 3.5 1.1 6.5 1.1 3.2 1 6.1 1.1 298 24 306 255 25.6 0 25.9 25.3 06/29/2005 15:40:00 3.6 1.3 7.2 0.7 3.5 1.3 6.8 0.7 3.1 1.4 6.8 0.4 302 27 311 255 25.8 0 26.2 25.6 06/29/2005 15:50:00 3.1 1.1 5.7 0.4 3 1.1 5.7 0.7 2.6 1.1 4.6 0.4 292 24 311 255 25 0.2 25.6 24.7 06/29/2005 16:00:00 3.4 1.1 6.5 0.4 3.2 1.1 6.5 0.4 2.6 1 6.5 0.7 297 24 301 255 25.2 0.3 25.6 24.4 06/29/2005 16:10:00 3.1 1 4.9 0.7 3.1 1.2 5.3 0.4 2.3 0.9 4.6 0.4 274 24 274 255 24.1 0.2 24.7 23.8 06/29/2005 16:20:00 4 1 6.1 1.5 4 1 6.1 1.9 3.4 1.1 6.1 1.1 285 22 270 255 23.6 0 23.8 23.2 06/29/2005 16:30:00 3.6 1 6.1 0.7 3.5 1.1 5.7 0.4 2.9 1 4.9 0.7 296 23 263 255 23.3 0 23.5 23.2 06/29/2005 16:40:00 3.3 1 5.3 1.1 3.3 1 5.7 1.1 2.6 1.1 5.3 0.4 294 23 281 255 23.3 0 23.5 23.2 06/29/2005 16:50:00 2.9 0.9 5.3 1.1 2.8 0.9 4.9 1.1 2.3 0.7 4.9 0.7 300 21 328 255 23.4 0 23.5 23.5 06/29/2005 17:00:00 3.6 1 6.1 0.7 3.5 1 6.1 0.7 2.9 1 6.5 0.7 311 16 303 255 23.5 0.1 23.8 23.5 06/29/2005 17:10:00 2.7 0.8 4.6 0.7 2.7 0.8 4.6 0.4 2.2 0.9 4.2 0.4 307 15 303 255 24 0 24.1 23.8 06/29/2005 17:20:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.4 0.7 3 0.4 304 29 309 255 23.7 0 23.8 23.5 06/29/2005 17:30:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.6 0.6 3.4 0.4 315 22 322 255 23 0.2 23.5 22.6 06/29/2005 17:40:00 2.2 0.9 4.2 0.4 2 1 4.2 0.4 1.5 0.8 3.8 0.4 352 20 34 255 22.4 0 22.9 22.3 06/29/2005 17:50:00 2.8 0.6 4.2 1.5 2.6 0.6 4.2 0.7 2.1 0.6 3.8 0.4 325 17 327 255 21.6 0.3 22.6 21.1 06/29/2005 18:00:00 2 1 4.2 0.4 1.8 1.1 4.6 0.4 1.4 0.9 3.4 0.4 313 19 311 255 21.1 0 21.7 21.1 06/29/2005 18:10:00 3.2 1.1 5.7 1.1 3.2 1.1 6.1 0.7 2.4 1.2 6.1 0.4 16 18 45 255 21.2 0 21.4 21.1 06/29/2005 18:20:00 3.8 0.5 5.3 2.6 3.8 0.5 5.3 2.6 3.3 0.5 4.6 1.9 34 9 40 255 20.6 0.2 21.1 20.3 06/29/2005 18:30:00 2.1 0.6 3.8 0.7 2 0.7 3.8 0.4 1.7 0.8 3.4 0.4 23 11 34 255 20.2 0.1 20.8 20 06/29/2005 18:40:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1 0.7 2.6 0.4 27 13 28 255 20.4 0 20.8 20.3 06/29/2005 18:50:00 1.4 0.7 3 0.4 1.2 0.8 3 0.4 0.9 0.6 2.6 0.4 39 19 34 255 20.5 0 21.1 20.5 06/29/2005 19:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 44 12 69 255 20.5 0 21.1 20.3 06/29/2005 19:10:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.5 0.4 48 17 349 255 20.3 0 20.8 20.3 06/29/2005 19:20:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 348 3 349 255 20.3 0 20.8 20.3 06/29/2005 19:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 335 0 335 255 20.2 0.1 20.5 20 06/29/2005 19:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 337 49 89 255 20 0.1 20.5 19.7 06/29/2005 19:50:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.5 0.4 82 10 68 255 19.7 0.1 20.3 19.4 06/29/2005 20:00:00 1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.4 2.3 0.4 5 27 350 255 19.7 0 20.3 19.4 06/29/2005 20:10:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.9 0.4 27 12 7 255 19.8 0 20.3 19.7 06/29/2005 20:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 22 17 317 255 20 0 20.3 20 06/29/2005 20:30:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 300 7 312 255 20 0 20.3 19.7 06/29/2005 20:40:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 293 2 305 255 19.7 0 20 19.7 06/29/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 292 0 255 255 19.5 0.1 20 19.4 06/29/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 292 0 255 255 19.5 0 20 19.4 06/29/2005 21:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.1 0.4 292 0 293 255 19.2 0.1 19.7 19.1 06/29/2005 21:20:00 0.9 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 332 24 293 255 18.9 0 19.1 18.8 06/29/2005 21:30:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.6 0.4 2.3 0.4 355 6 349 255 18.7 0 18.8 18.5 06/29/2005 21:40:00 1.6 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.1 0.5 1.9 0.4 13 22 350 255 18.4 0 18.5 18.2 06/29/2005 21:50:00 1.3 0.3 2.3 0.4 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 27 9 40 255 18.2 0 18.2 18 06/29/2005 22:00:00 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 33 17 33 255 17.8 0 18.2 17.4 06/29/2005 22:10:00 0.8 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.7 0.3 1.5 0.4 59 0 59 255 17.5 0.1 17.7 17.1 06/29/2005 22:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 59 0 60 255 17.2 0 17.4 17.1 06/29/2005 22:30:00 1.1 0.4 2.3 0.4 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 78 9 90 255 17.3 0 17.4 17.1 06/29/2005 22:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 69 27 94 255 17.1 0 17.4 16.8 06/29/2005 22:50:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 59 0 60 255 16.8 0 17.1 16.8 06/29/2005 23:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 59 0 59 255 16.7 0 17.1 16.6 06/29/2005 23:10:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.5 0.3 1.5 0.4 42 23 2 255 16.4 0 16.8 16.3 06/29/2005 23:20:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1 0.5 2.3 0.4 7 13 357 255 16.1 0 16.8 16 06/29/2005 23:30:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 26 9 4 255 16 0 16.3 16 06/29/2005 23:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 16 10 12 255 15.8 0 16.3 15.7 06/29/2005 23:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 40 0 40 255 15.7 0 16 15.5 06/30/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 255 255 15.5 0 16 15.2 06/30/2005 00:10:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 24 9 38 255 15.1 0.1 15.7 14.9 06/30/2005 00:20:00 0.8 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 19 0 19 255 15 0 15.5 14.9 06/30/2005 00:30:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 13 8 3 255 14.6 0 15.2 14.6 06/30/2005 00:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 3 0 3 255 14.4 0.1 14.9 14.1 06/30/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 255 255 14.2 0.1 14.6 13.8 06/30/2005 01:00:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 3 0 3 255 14.1 0.1 14.6 13.8 06/30/2005 01:10:00 1.3 0.3 1.9 0.4 1.2 0.3 1.5 0.4 0.8 0.3 1.5 0.4 12 6 19 255 13.9 0 14.4 13.8 06/30/2005 01:20:00 1.2 0.2 1.5 0.4 1 0.2 1.5 0.4 0.7 0.3 1.5 0.4 18 3 20 255 13.8 0 14.4 13.8 06/30/2005 01:30:00 1.1 0.3 1.9 0.4 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 18 3 16 255 13.9 0 14.4 13.8 06/30/2005 01:40:00 0.8 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 15 0 15 255 13.8 0 14.4 13.8 06/30/2005 01:50:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 21 9 13 255 13.9 0 14.4 13.8 06/30/2005 02:00:00 1.2 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.9 0.3 1.5 0.4 46 7 45 255 13.8 0 14.4 13.8 06/30/2005 02:10:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 45 10 37 255 13.7 0 14.4 13.5 06/30/2005 02:20:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 76 17 106 255 13.5 0 14.1 13.3 06/30/2005 02:30:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.8 0.4 1.5 0.4 85 9 94 255 13.3 0 13.8 13.3 06/30/2005 02:40:00 1.5 0.3 2.3 0.7 1.4 0.3 1.9 0.7 0.8 0.4 1.9 0.4 77 4 71 255 13.1 0 13.3 12.7 06/30/2005 02:50:00 1.6 0.3 2.3 0.7 1.5 0.4 2.3 0.7 0.7 0.4 1.9 0.4 92 8 98 255 12.9 0 13.3 12.7 06/30/2005 03:00:00 1.9 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.1 0.4 1.9 0.4 99 11 106 255 12.9 0 13.3 12.7 06/30/2005 03:10:00 2.2 0.4 3 1.5 2.2 0.4 3 1.1 1.4 0.3 2.6 0.7 87 6 90 255 13.1 0 13.5 12.7 06/30/2005 03:20:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.7 0.5 3 0.4 79 11 81 255 13.1 0 13.5 12.7 06/30/2005 03:30:00 1.3 0.8 3 0.4 1.2 0.8 3.4 0.4 0.9 0.5 1.9 0.4 78 13 84 255 13.3 0 13.8 13.3 06/30/2005 03:40:00 2.1 0.6 3.8 0.4 2 0.6 3.8 0.4 1.3 0.6 2.6 0.4 59 14 51 255 13.2 0 13.5 13 06/30/2005 03:50:00 2.1 0.4 3 1.1 2 0.4 3 0.7 1.2 0.5 2.3 0.4 80 10 81 255 13 0.1 13.3 12.7 06/30/2005 04:00:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.3 1.9 0.4 99 18 89 255 12.5 0.1 12.7 12.2 06/30/2005 04:10:00 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 101 16 86 255 12.3 0 12.7 12.2 06/30/2005 04:20:00 2.6 0.3 3.4 1.5 2.5 0.4 3.4 1.5 1.6 0.5 3 0.4 102 8 94 255 12.3 0 13 12.2 06/30/2005 04:30:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 0.4 1.9 0.5 3 0.7 109 11 108 255 12.9 0.2 13.5 12.7 06/30/2005 04:40:00 2.6 0.6 3.8 1.1 2.5 0.6 3.8 0.7 1.9 0.5 3.4 0.7 100 21 119 255 13.6 0.2 13.8 13.3 06/30/2005 04:50:00 2.7 0.7 4.6 1.1 2.6 0.7 4.6 0.7 2.1 0.7 3.8 0.4 66 17 57 255 14.4 0.2 14.6 13.8 06/30/2005 05:00:00 1.5 0.5 3 0.4 1.4 0.6 3 0.4 1 0.5 2.3 0.4 79 14 52 255 14.8 0 15.2 14.6 06/30/2005 05:10:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.6 0.6 3 0.4 56 15 65 255 15 0 15.2 14.9 06/30/2005 05:20:00 1.9 0.5 2.6 0.4 1.8 0.6 2.6 0.4 1.6 0.6 2.6 0.4 50 17 51 255 15.2 0 15.7 15.2 06/30/2005 05:30:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.3 0.4 2.3 0.4 103 13 88 255 15.5 0 16 15.5 06/30/2005 05:40:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 103 9 105 255 15.6 0 16.3 15.5 06/30/2005 05:50:00 1.5 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.1 0.4 2.3 0.4 93 11 88 255 15.7 0.1 16.3 15.7 06/30/2005 06:00:00 2.2 0.5 4.2 1.1 2.1 0.6 4.2 1.1 1.8 0.5 3.8 0.7 80 15 62 255 15.9 0.1 16.6 15.7 06/30/2005 06:10:00 3.5 0.8 5.3 1.5 3.5 0.9 5.7 1.1 3 0.8 5.3 1.1 66 16 49 255 16.2 0.1 16.8 16.3 06/30/2005 06:20:00 3.3 0.7 4.9 1.9 3.3 0.8 5.3 1.5 2.7 0.7 4.6 0.7 46 18 45 255 16.3 0.1 16.8 16.3 06/30/2005 06:30:00 2.6 0.5 4.2 1.1 2.6 0.5 4.2 1.1 1.7 0.6 3.4 0.4 5 17 43 255 16.4 0.1 16.8 16.3 06/30/2005 06:40:00 2.3 0.5 3.4 0.7 2.3 0.6 3.4 0.4 1.5 0.6 3 0.4 12 13 19 255 16.3 0.2 16.8 16.3 06/30/2005 06:50:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.7 0.5 3 0.4 15 13 25 255 16.1 0 16.8 16.3 06/30/2005 07:00:00 2.9 0.5 4.2 1.5 2.9 0.5 3.8 1.1 2.4 0.7 3.8 0.4 27 11 18 255 16.1 0 16.6 16 06/30/2005 07:10:00 2.7 0.6 3.8 1.1 2.7 0.6 4.2 1.1 2.4 0.7 3.8 0.7 29 13 51 255 16 0 16.6 15.7 06/30/2005 07:20:00 2.4 0.5 3.8 0.7 2.3 0.5 4.2 0.7 1.8 0.6 3 0.4 18 12 8 255 15.7 0 16.3 15.5 06/30/2005 07:30:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 1.1 1.6 0.8 3.4 0.4 13 13 30 255 15.6 0 16 15.5 06/30/2005 07:40:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1 0.6 2.3 0.4 6 15 8 255 15.9 0.1 16.6 15.7 06/30/2005 07:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 339 13 341 255 16.5 0 16.8 16.3 06/30/2005 08:00:00 1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 0.8 0.5 1.9 0.4 338 12 352 255 16.8 0 17.1 16.6 06/30/2005 08:10:00 1.2 0.6 2.6 0.4 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 346 15 332 255 17.7 0.4 18.2 16.8 06/30/2005 08:20:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 357 11 12 255 18.2 0 18.5 18 06/30/2005 08:30:00 1.7 0.6 3 0.4 1.7 0.6 2.6 0.4 1.3 0.7 3 0.4 11 15 21 255 17.9 0 18 17.7 06/30/2005 08:40:00 1.3 0.5 3 0.4 1.2 0.5 3 0.4 1.1 0.5 2.3 0.4 19 15 24 255 18 0 18.2 18 06/30/2005 08:50:00 1.7 0.4 3 0.7 1.5 0.5 3 0.4 1.4 0.6 3 0.4 25 17 40 255 18 0 18.2 17.7 06/30/2005 09:00:00 1.2 0.5 2.3 0.4 1.1 0.5 1.9 0.4 1.1 0.5 2.3 0.4 35 22 24 255 18.4 0.1 18.5 18 06/30/2005 09:10:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 1.1 0.5 1.9 0.4 37 9 28 255 18.5 0 18.5 18.2 06/30/2005 09:20:00 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 34 15 11 255 18.5 0 18.5 18.2 06/30/2005 09:30:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.4 1.9 0.4 36 30 359 255 19 0.3 19.7 18.5 06/30/2005 09:40:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 1.3 0.4 2.3 0.4 343 22 355 255 19.7 0 20.5 19.4 06/30/2005 09:50:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 349 18 325 255 20.2 0.1 20.8 20 06/30/2005 10:00:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 321 24 305 255 20.2 0 20.5 20 06/30/2005 10:10:00 1.9 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.6 0.7 3 0.4 324 24 274 255 19.8 0 20.3 19.4 06/30/2005 10:20:00 1.9 0.5 3 0.4 1.8 0.5 3.4 0.4 1.6 0.6 3 0.4 313 15 313 255 19.5 0 20.3 19.4 06/30/2005 10:30:00 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 1.2 0.6 2.6 0.4 303 28 314 255 19.6 0.1 20.3 19.4 06/30/2005 10:40:00 1.7 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.4 0.7 3 0.4 309 17 305 255 20.3 0.3 20.8 19.4 06/30/2005 10:50:00 1.9 0.5 3.4 0.4 1.8 0.6 3.8 0.4 1.9 0.5 3.4 0.7 313 18 303 255 21 0.2 21.7 20.5 06/30/2005 11:00:00 2.1 0.7 3.4 0.4 2 0.7 3.4 0.4 1.8 0.7 3.8 0.4 287 26 276 255 20.2 0.2 20.8 19.7 06/30/2005 11:10:00 2.4 0.8 4.2 0.4 2.3 0.9 4.2 0.4 2.1 0.8 4.2 0.7 299 19 320 255 19.7 0.2 20.3 19.4 06/30/2005 11:20:00 2.6 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2.2 1 4.6 0.4 290 23 280 255 19.5 0 20 19.1 06/30/2005 11:30:00 2.9 0.7 4.9 1.1 2.8 0.8 4.6 0.7 2.4 0.8 4.2 0.4 296 17 293 255 19.2 0 19.7 18.8 06/30/2005 11:40:00 2.8 0.6 4.2 1.5 2.8 0.7 4.6 1.5 2.5 0.8 4.6 0.7 285 17 287 255 18.7 0.2 19.4 18.2 06/30/2005 11:50:00 2.6 0.7 4.6 0.7 2.5 0.8 4.6 0.4 2.1 0.8 3.8 0.4 287 22 253 255 18.6 0.2 19.1 18.2 06/30/2005 12:00:00 2.2 1 4.6 0.4 2.2 1 4.6 0.4 1.8 1 4.6 0.4 284 26 323 255 18.7 0 19.1 18.5 06/30/2005 12:10:00 2.7 0.7 4.6 0.7 2.6 0.8 4.6 0.7 2.1 0.8 4.9 0.4 283 18 290 255 19 0.1 19.7 18.8 06/30/2005 12:20:00 1.7 0.9 4.2 0.4 1.7 0.9 4.2 0.4 1.5 0.8 4.2 0.4 277 26 287 255 19.4 0 20 19.1 06/30/2005 12:30:00 2.3 1 4.6 0.4 2.1 1.1 4.6 0.4 1.9 1 4.6 0.4 266 51 276 255 19.2 0 20 19.1 06/30/2005 12:40:00 3 0.8 4.6 0.7 2.9 0.9 4.9 0.4 2.4 1 4.2 0.4 289 24 263 255 18.7 0.3 19.4 18.2 06/30/2005 12:50:00 2.8 0.9 4.6 0.7 2.7 1 4.6 0.4 2.5 0.8 4.2 0.7 283 17 283 255 17.5 0.4 18.8 16.8 06/30/2005 13:00:00 2.3 0.7 4.6 0.7 2.3 0.8 4.2 0.4 1.9 0.8 4.9 0.4 280 15 274 255 16.8 0 17.1 16.8 06/30/2005 13:10:00 1 0.6 2.6 0.4 1 0.6 3 0.4 0.8 0.5 2.6 0.4 259 22 252 255 17.1 0.2 17.4 16.8 06/30/2005 13:20:00 0.6 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 277 26 277 255 17.8 0 18.2 17.4 06/30/2005 13:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.6 2.6 0.4 309 17 311 255 18.2 0 18.2 18 06/30/2005 13:40:00 1.3 0.7 3.4 0.4 1.2 0.7 3 0.4 1 0.6 2.6 0.4 293 30 269 255 18.5 0 18.8 18.2 06/30/2005 13:50:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 313 22 289 255 19.1 0 19.4 18.8 06/30/2005 14:00:00 1.8 0.5 3 0.7 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 306 15 304 255 19.6 0 20 19.4 06/30/2005 14:10:00 1.7 0.6 3 0.4 1.6 0.6 3.4 0.4 1.3 0.6 2.6 0.4 321 21 293 255 20 0 20.5 19.7 06/30/2005 14:20:00 2.3 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.8 0.8 3.4 0.4 3 17 28 255 20 0 20.5 19.7 06/30/2005 14:30:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.1 2.1 0.6 3.8 0.4 11 16 9 255 20.3 0.2 21.1 20 06/30/2005 14:40:00 3.1 0.6 4.9 0.7 3 0.6 4.6 1.5 2.3 0.7 4.2 0.7 10 15 13 255 20.7 0.1 21.1 20.5 06/30/2005 14:50:00 3 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2.1 0.7 4.2 0.4 2 14 28 255 20.7 0.1 21.1 20.5 06/30/2005 15:00:00 2.7 0.8 4.6 0.7 2.6 0.8 4.6 0.4 2.2 0.9 4.2 0.4 18 13 357 255 20.6 0 21.1 20.5 06/30/2005 15:10:00 3.3 0.5 4.2 1.9 3.2 0.5 4.2 1.9 2.8 0.6 4.2 1.5 19 10 3 255 20.6 0.1 21.1 20.5 06/30/2005 15:20:00 2.7 0.7 4.2 1.1 2.6 0.7 4.6 1.1 2.4 0.7 4.2 0.7 28 11 37 255 20.6 0.1 21.1 20.5 06/30/2005 15:30:00 2.2 0.8 3.8 0.4 2 0.9 3.8 0.4 1.8 0.8 3.8 0.4 4 32 26 255 20.8 0.2 21.4 20.5 06/30/2005 15:40:00 2.2 0.7 3.4 0.7 1.9 0.7 3.4 0.4 1.5 0.9 3.8 0.4 341 21 348 255 21.3 0 21.7 21.1 06/30/2005 15:50:00 2.1 0.9 4.2 0.4 1.9 0.8 3.8 0.4 1.7 0.8 3.4 0.4 337 27 334 255 21.2 0 21.7 21.1 06/30/2005 16:00:00 3 0.9 4.9 1.1 3 0.9 4.9 0.7 2.6 1 4.6 0.4 303 13 319 255 21.3 0 21.7 21.1 06/30/2005 16:10:00 2.4 1.2 4.9 0.4 2.3 1.2 4.9 0.4 2.1 1 4.6 0.4 300 27 297 255 20.8 0.1 21.4 20.5 06/30/2005 16:20:00 2.8 0.9 4.9 0.4 2.8 0.9 4.6 0.7 2.3 0.9 4.9 0.4 300 18 301 255 20.5 0 20.8 20.5 06/30/2005 16:30:00 2.3 0.8 4.2 0.4 2.1 0.8 4.2 0.4 2 0.7 3.8 0.4 303 19 317 255 20.3 0.1 20.8 20 06/30/2005 16:40:00 2.4 1 4.6 0.4 2.3 0.9 4.6 0.4 2 0.9 4.9 0.4 303 17 292 255 20 0.1 20.5 19.4 06/30/2005 16:50:00 2.5 0.5 3.8 0.7 2.1 0.6 3.8 0.7 1.7 0.7 3.4 0.4 333 16 342 255 19.5 0.1 20.3 19.1 06/30/2005 17:00:00 2.7 0.5 4.2 1.1 2.3 0.6 3.4 0.4 1.9 0.6 3.4 0.4 341 13 358 255 19 0.1 19.7 18.5 06/30/2005 17:10:00 2 0.4 3.4 0.7 1.6 0.5 3 0.4 1.5 0.5 3 0.4 342 13 336 255 18.5 0.1 19.1 18.2 06/30/2005 17:20:00 1.3 0.5 2.3 0.4 0.9 0.5 2.6 0.4 1 0.5 2.6 0.4 339 11 4 255 18.4 0 18.8 18.2 06/30/2005 17:30:00 1.2 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.9 0.6 2.3 0.4 345 19 329 255 18.6 0 18.5 18.5 06/30/2005 17:40:00 1.9 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.3 0.5 2.6 0.4 353 11 343 255 19 0.1 19.4 18.5 06/30/2005 17:50:00 2.3 0.7 3.8 0.4 2.2 0.8 3.4 0.4 1.8 0.8 3.8 0.4 5 15 14 255 19.4 0 19.4 19.1 06/30/2005 18:00:00 3 0.4 3.8 2.3 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.5 24 7 25 255 19 0 19.4 18.8 06/30/2005 18:10:00 2.2 0.9 3.4 0.4 2.1 1 3.4 0.4 1.6 1 3.4 0.4 13 16 20 255 18.8 0 18.8 18.5 06/30/2005 18:20:00 2.3 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1.7 0.6 3 0.4 348 15 357 255 18.6 0 18.8 18.5 06/30/2005 18:30:00 1.8 0.5 3.4 0.4 1.6 0.6 3 0.4 1.2 0.6 2.6 0.4 0 13 8 255 18.4 0 18.5 18.2 06/30/2005 18:40:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 2.3 0.4 348 15 349 255 18.2 0 18.2 18 06/30/2005 18:50:00 1.1 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.5 0.4 353 12 342 255 18.2 0 18.2 18 06/30/2005 19:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.4 1.5 0.4 342 3 343 255 18.3 0 18.2 18.2 06/30/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 18.5 0 18.5 18.2 06/30/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 18.6 0 18.8 18.5 06/30/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 18.3 0 18.5 18 06/30/2005 19:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 238 47 217 255 18.2 0 18.2 18 06/30/2005 19:50:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 189 6 193 255 18 0 18.2 17.7 06/30/2005 20:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 188 0 189 255 17.8 0 18 17.7 06/30/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 17.8 0 18 17.7 06/30/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 17.8 0 17.7 17.7 06/30/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 17.7 0 17.7 17.4 06/30/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 18 255 255 17.5 0 17.7 17.4 06/30/2005 20:50:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 320 12 327 255 17.4 0 17.7 17.1 06/30/2005 21:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 313 6 311 255 17.3 0 17.4 17.1 06/30/2005 21:10:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 349 9 334 255 17.3 0 17.7 16.8 06/30/2005 21:20:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 14 16 42 255 17.1 0 17.4 16.8 06/30/2005 21:30:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 27 15 37 255 17 0 17.4 16.8 06/30/2005 21:40:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 38 11 51 255 16.9 0 17.4 16.8 06/30/2005 21:50:00 1.3 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.1 0.5 2.6 0.4 50 15 19 255 17 0 17.4 16.8 06/30/2005 22:00:00 1.2 0.4 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 65 9 70 255 16.9 0.1 17.1 16.8 06/30/2005 22:10:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 1.4 0.5 3 0.4 46 12 45 255 16.8 0 17.1 16.6 06/30/2005 22:20:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.5 0.5 2.3 0.4 57 15 53 255 16.7 0 17.1 16.6 06/30/2005 22:30:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 62 15 45 255 16.5 0 16.8 16.3 06/30/2005 22:40:00 1.4 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.4 0.4 2.6 0.4 46 15 45 255 16.4 0 16.8 16.3 06/30/2005 22:50:00 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.6 2.3 0.4 26 22 23 255 16.2 0 16.8 16.3 06/30/2005 23:00:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 25 11 40 255 16 0 16.8 15.7 06/30/2005 23:10:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.5 0.6 2.6 0.4 21 13 28 255 15.7 0 16.3 15.7 06/30/2005 23:20:00 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.1 1.8 0.6 3.4 0.4 349 18 336 255 15.5 0 16 15.2 06/30/2005 23:30:00 2.8 0.6 4.2 1.1 2.6 0.6 4.2 1.1 1.6 0.9 4.2 0.4 354 17 341 255 15.2 0.1 15.7 14.9 06/30/2005 23:40:00 1.7 0.6 3.8 0.4 1.5 0.7 3.8 0.4 1.1 0.7 2.6 0.4 27 29 5 255 14.6 0 15.2 14.6 06/30/2005 23:50:00 0.8 0.6 2.3 0.4 0.7 0.5 2.6 0.4 0.7 0.5 1.9 0.4 36 10 55 255 14.5 0 15.2 14.6 07/01/2005 00:00:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 36 24 33 255 14.5 0 15.2 14.6 07/01/2005 00:10:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 37 11 32 255 14.5 0 15.2 14.4 07/01/2005 00:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 35 12 41 255 14.4 0 14.9 14.4 07/01/2005 00:30:00 1.5 1 3.8 0.4 1.4 1 3.8 0.4 1.2 0.8 3.4 0.4 311 14 302 255 14.4 0.1 14.9 14.4 07/01/2005 00:40:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 4 13 358 255 14.3 0 14.6 14.1 07/01/2005 00:50:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 338 36 16 255 14.3 0 14.6 14.1 07/01/2005 01:00:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 277 5 271 255 14.2 0 14.6 14.1 07/01/2005 01:10:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 274 19 257 255 14.3 0 14.9 14.4 07/01/2005 01:20:00 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 329 10 314 255 14.4 0 14.9 14.4 07/01/2005 01:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 329 0 329 255 14.4 0 14.9 14.4 07/01/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 255 255 14.4 0.1 14.9 14.4 07/01/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 255 255 14.3 0.1 14.6 14.1 07/01/2005 02:00:00 0.7 0.6 1.9 0.4 0.8 0.6 1.9 0.4 0.4 0.2 1.5 0.4 350 23 17 255 14.2 0.2 14.6 14.1 07/01/2005 02:10:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 44 16 58 255 14.1 0.1 14.6 14.1 07/01/2005 02:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 73 6 75 255 14.2 0.2 14.6 14.1 07/01/2005 02:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 90 13 71 255 14.1 0 14.6 13.8 07/01/2005 02:40:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 64 10 81 255 14 0 14.1 13.8 07/01/2005 02:50:00 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.7 1 0.5 1.9 0.4 89 7 86 255 13.9 0 14.4 13.8 07/01/2005 03:00:00 2.1 0.5 3 0.7 2.1 0.4 3 0.7 1.5 0.5 2.6 0.4 92 8 96 255 13.9 0 13.8 13.8 07/01/2005 03:10:00 1.4 0.5 2.3 0.4 1.5 0.5 2.6 0.4 0.9 0.5 1.9 0.4 89 14 80 255 13.9 0 14.1 13.8 07/01/2005 03:20:00 0.8 0.5 1.9 0.4 0.9 0.4 2.3 0.4 0.5 0.3 1.9 0.4 100 1 99 255 13.9 0 14.4 13.8 07/01/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 255 255 13.9 0 14.4 13.8 07/01/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 255 255 13.8 0 14.1 13.8 07/01/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 176 17 255 255 13.7 0 14.1 13.5 07/01/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 180 0 255 255 13.7 0 13.8 13.5 07/01/2005 04:10:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 206 43 180 255 13.7 0 13.8 13.5 07/01/2005 04:20:00 0.9 0.4 1.5 0.4 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 287 7 284 255 13.7 0 13.8 13.5 07/01/2005 04:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 278 5 277 255 13.7 0 13.8 13.8 07/01/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 282 0 255 255 13.9 0 14.4 13.8 07/01/2005 04:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 11 30 255 255 14 0 14.4 13.8 07/01/2005 05:00:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 38 16 55 255 14.1 0.1 14.6 13.8 07/01/2005 05:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 55 0 55 255 14.2 0.1 14.6 14.1 07/01/2005 05:20:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 55 0 55 255 14.4 0.2 14.9 14.1 07/01/2005 05:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 73 17 55 255 14.4 0.1 14.9 14.4 07/01/2005 05:40:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 70 16 87 255 14.4 0 14.9 14.4 07/01/2005 05:50:00 0.6 0.4 1.9 0.4 0.8 0.4 2.3 0.4 0.6 0.3 1.5 0.4 68 7 65 255 14.4 0 14.9 14.4 07/01/2005 06:00:00 1.7 0.7 3 0.4 1.8 0.7 3.4 0.4 0.8 0.5 2.6 0.4 18 29 6 255 14.4 0 14.9 14.4 07/01/2005 06:10:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.2 0.7 2.6 0.4 4 14 1 255 14.2 0.1 14.9 13.8 07/01/2005 06:20:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.5 0.8 3.4 0.4 18 12 17 255 13.8 0 14.6 13.5 07/01/2005 06:30:00 1.9 0.6 3 0.4 2 0.6 3 0.4 1.4 0.7 3 0.4 32 13 40 255 13.4 0 13.8 13.3 07/01/2005 06:40:00 0.9 0.6 2.6 0.4 1 0.6 3 0.4 0.8 0.6 2.6 0.4 56 15 40 255 13.4 0 13.8 13.3 07/01/2005 06:50:00 1 0.5 2.3 0.4 1.2 0.5 1.9 0.4 0.8 0.4 1.9 0.4 56 9 42 255 13.5 0.1 14.1 13.3 07/01/2005 07:00:00 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 55 9 58 255 13.5 0 13.8 13.5 07/01/2005 07:10:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.5 2.3 0.4 34 9 32 255 13.8 0 14.4 13.5 07/01/2005 07:20:00 1.4 0.6 2.6 0.4 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 65 12 74 255 13.9 0 14.4 13.8 07/01/2005 07:30:00 1.9 0.6 3.8 0.7 1.9 0.6 3.4 0.4 1.6 0.7 3 0.4 59 15 73 255 13.9 0 14.4 13.8 07/01/2005 07:40:00 2 0.5 3 1.1 2 0.5 3 0.7 1.7 0.5 3.4 0.4 52 11 43 255 13.9 0 14.1 13.8 07/01/2005 07:50:00 0.9 0.6 2.3 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 69 16 49 255 13.9 0 14.4 13.8 07/01/2005 08:00:00 0.7 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 74 18 62 255 14.2 0 14.6 14.1 07/01/2005 08:10:00 1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 56 16 53 255 14.2 0 14.6 14.4 07/01/2005 08:20:00 1.7 0.7 3.4 0.4 1.9 0.6 3.4 0.4 1.5 0.6 2.6 0.4 46 17 49 255 14.4 0 14.6 14.4 07/01/2005 08:30:00 1.1 0.6 2.3 0.4 1.4 0.6 2.6 0.4 1 0.5 2.3 0.4 75 18 59 255 14.5 0 15.2 14.6 07/01/2005 08:40:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.3 1.5 0.4 83 15 86 255 14.6 0 15.2 14.6 07/01/2005 08:50:00 0.7 0.5 1.9 0.4 1 0.5 2.3 0.4 0.7 0.3 1.5 0.4 92 19 115 255 14.8 0 15.5 14.9 07/01/2005 09:00:00 0.9 0.7 3 0.4 1 0.7 2.6 0.4 0.7 0.5 2.6 0.4 85 19 79 255 15 0.1 15.7 14.9 07/01/2005 09:10:00 1.5 0.8 3.4 0.4 1.7 0.7 3 0.4 1.3 0.6 3.4 0.4 75 21 90 255 15.1 0.1 15.7 15.2 07/01/2005 09:20:00 2.5 0.8 4.6 0.4 2.6 0.7 4.6 0.4 2.1 0.9 3.8 0.4 52 15 46 255 15 0 15.7 14.9 07/01/2005 09:30:00 1.1 0.7 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 58 19 62 255 15.2 0.1 15.7 14.9 07/01/2005 09:40:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 31 21 42 255 15.7 0.1 16.3 15.5 07/01/2005 09:50:00 1.9 0.7 3.4 0.4 2 0.6 3.4 0.4 1.7 0.6 3 0.4 53 12 44 255 15.9 0.1 16.6 15.7 07/01/2005 10:00:00 2.2 0.8 4.6 0.4 2.2 0.8 4.2 0.4 1.9 0.8 3.8 0.4 50 17 47 255 16 0.2 16.6 15.7 07/01/2005 10:10:00 3 0.8 4.6 0.7 3 0.8 4.6 0.7 2.5 1 4.6 0.4 32 15 35 255 16.2 0 16.6 16 07/01/2005 10:20:00 3.8 0.7 5.7 1.9 3.8 0.8 5.7 1.9 3.2 0.8 5.3 0.7 33 12 35 255 16.4 0.2 17.1 16.3 07/01/2005 10:30:00 4.2 0.9 6.8 1.9 4.2 0.9 6.8 1.5 3.4 1.1 6.1 1.1 29 16 40 255 16.6 0.2 17.1 16.3 07/01/2005 10:40:00 3.4 0.8 5.3 0.7 3.4 0.8 5.3 0.7 2.9 0.8 5.3 0.7 25 17 51 255 17.4 0.1 18 16.8 07/01/2005 10:50:00 4.3 1 6.8 1.9 4.2 1 6.8 1.9 3.5 1.1 6.8 0.7 33 17 42 255 17.8 0 18 17.4 07/01/2005 11:00:00 4.6 0.8 7.2 2.3 4.5 0.9 6.8 2.3 3.8 1 6.1 1.1 34 11 29 255 17 0.1 17.4 16.8 07/01/2005 11:10:00 5.2 0.9 7.2 3 5.2 0.9 7.2 3 4.5 1 6.8 2.6 35 13 34 255 17.2 0.3 18 16.8 07/01/2005 11:20:00 5.4 1 7.6 3.4 5.3 1 7.6 3 4.4 1.1 7.2 1.9 33 14 35 255 18.3 0.1 18.5 17.7 07/01/2005 11:30:00 4.9 1 7.2 1.5 4.9 1 7.2 1.5 4.2 1.1 6.8 0.7 41 13 42 255 18 0.3 18.5 17.4 07/01/2005 11:40:00 3.7 0.8 5.7 1.1 3.7 0.8 5.7 1.5 3.1 0.8 5.3 0.7 54 18 18 255 17.3 0 17.4 17.1 07/01/2005 11:50:00 3.6 1 6.5 1.5 3.6 1 6.8 1.1 3.1 0.9 5.3 1.1 56 19 40 255 17.3 0 17.7 17.1 07/01/2005 12:00:00 4.7 1 7.6 2.3 4.8 1 7.2 1.9 4.3 1 6.5 1.5 49 17 77 255 17.9 0.1 18.2 17.4 07/01/2005 12:10:00 5.5 1.1 7.6 1.9 5.7 1.1 8 2.3 4.6 1.2 8 1.5 47 17 25 255 18.4 0 18.5 18.2 07/01/2005 12:20:00 5.5 0.8 7.2 3 5.6 0.8 7.2 3.4 4.7 1 6.8 2.3 39 11 12 255 18.5 0.2 19.1 18.2 07/01/2005 12:30:00 4.4 0.8 6.1 2.3 4.6 0.8 6.8 2.6 3.8 0.8 6.1 1.9 45 20 59 255 19.1 0 19.7 18.8 07/01/2005 12:40:00 4.6 1 6.8 1.9 4.7 1 6.5 2.3 3.9 1.1 6.5 1.5 21 17 25 255 19.2 0 20 19.1 07/01/2005 12:50:00 4.5 1 7.2 1.5 4.5 1 6.8 1.9 3.5 1.1 6.1 1.1 18 15 7 255 19.7 0.2 20.5 19.4 07/01/2005 13:00:00 4.6 0.8 7.2 2.6 4.7 0.9 7.6 2.6 3.8 1 6.1 1.1 28 18 13 255 20.5 0 20.8 20.3 07/01/2005 13:10:00 4.7 0.8 6.5 2.3 4.7 0.9 6.8 2.3 4.1 1 6.5 1.1 39 16 31 255 20.6 0.1 21.1 20.3 07/01/2005 13:20:00 5 1.1 7.2 1.1 5.1 1 7.2 1.9 4.4 1.1 6.8 1.9 39 21 47 255 20.7 0 21.1 20.5 07/01/2005 13:30:00 4.6 0.8 6.8 2.3 4.7 0.9 6.8 2.3 3.9 0.8 6.1 1.9 25 15 12 255 21.1 0 21.1 21.1 07/01/2005 13:40:00 4.3 1.1 6.5 1.5 4.3 1.1 6.5 1.1 3.5 1.4 6.8 1.1 18 18 32 255 21.4 0 21.7 21.1 07/01/2005 13:50:00 4.3 0.9 6.5 1.9 4.3 0.9 6.8 1.9 3.4 1.1 6.1 1.1 22 20 54 255 21.9 0.1 22.3 21.4 07/01/2005 14:00:00 4.7 0.9 6.8 2.3 4.7 1 6.8 1.9 3.8 1.1 6.1 0.7 22 21 30 255 22.1 0.3 22.9 21.4 07/01/2005 14:10:00 4.4 1.2 6.8 1.5 4.4 1.2 6.8 1.5 3.3 1.1 6.8 0.7 12 15 21 255 21.9 0.1 22.3 21.4 07/01/2005 14:20:00 3.8 0.8 5.3 1.9 3.9 0.8 5.7 1.9 3.2 1 5.7 1.1 22 14 25 255 22.1 0 22.6 22 07/01/2005 14:30:00 3.3 1 5.7 0.7 3.4 1 5.7 0.7 2.8 1 4.9 0.4 29 26 23 255 22.1 0 22.6 22 07/01/2005 14:40:00 3.8 0.8 5.7 1.5 4 0.9 6.1 1.5 3.5 1 6.1 1.1 30 17 30 255 22.2 0 22.6 22 07/01/2005 14:50:00 3.3 1.1 5.7 0.4 3.5 1.2 6.5 0.7 2.9 1.2 5.7 0.4 17 18 16 255 22.4 0 22.6 22.3 07/01/2005 15:00:00 3.2 0.9 4.9 0.4 3.6 1 5.7 0.7 3 1 5.7 0.7 33 21 323 255 22.4 0.1 22.6 21.7 07/01/2005 15:10:00 3 0.9 5.3 0.7 3.3 1 6.1 0.7 2.8 1 5.3 0.7 30 21 340 255 22.1 0 22.6 21.7 07/01/2005 15:20:00 2.9 0.7 4.6 1.5 3.2 0.9 5.3 1.1 2.8 0.8 4.9 0.7 359 19 22 255 22.7 0.1 22.9 22.3 07/01/2005 15:30:00 1.7 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.5 0.6 3 0.4 4 51 335 255 22.7 0 23.2 22.3 07/01/2005 15:40:00 2.7 1 4.9 0.4 2.8 1.3 5.3 0.4 2.2 1.2 4.9 0.4 4 33 22 255 22.9 0.4 23.5 22 07/01/2005 15:50:00 3.3 0.8 5.3 1.1 3.6 1 5.7 1.1 2.8 1.2 5.7 0.4 14 13 34 255 21.6 0 22 21.4 07/01/2005 16:00:00 3.5 0.6 5.3 1.9 3.7 0.8 5.7 1.9 2.9 0.8 5.3 1.1 9 14 359 255 21.9 0 22.3 21.4 07/01/2005 16:10:00 3.7 0.6 5.3 1.9 3.9 0.7 5.7 1.9 3.3 0.9 5.3 1.1 19 13 49 255 21.8 0.3 22.3 21.1 07/01/2005 16:20:00 3.3 0.7 4.6 1.1 3.2 0.7 4.9 0.4 2.7 0.8 4.2 0.4 13 13 17 255 20.7 0.2 21.4 20.5 07/01/2005 16:30:00 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.8 0.7 4.2 1.1 23 12 25 255 20.9 0.1 21.1 20.5 07/01/2005 16:40:00 2.6 0.5 3.4 1.1 2.5 0.6 3.4 0.7 1.9 0.8 3.4 0.4 16 13 23 255 20.1 0.2 20.8 19.7 07/01/2005 16:50:00 2.6 0.6 4.2 0.7 2.5 0.7 3.8 0.4 2 0.8 3.8 0.4 1 14 358 255 19.6 0.1 20 19.4 07/01/2005 17:00:00 2.2 0.6 3.4 0.4 2 0.6 3.4 0.4 1.5 0.7 3.4 0.4 0 15 19 255 19.5 0 20 19.4 07/01/2005 17:10:00 1.5 0.6 3.4 0.4 1.4 0.6 2.6 0.4 1.2 0.5 2.3 0.4 352 24 343 255 20.3 0 20.5 20 07/01/2005 17:20:00 2.3 0.5 3.8 1.1 2.2 0.6 3.8 1.1 1.8 0.6 3.4 0.4 353 17 24 255 20.5 0.1 20.8 20.3 07/01/2005 17:30:00 2.7 0.6 4.6 1.1 2.5 0.7 4.2 1.1 2 0.5 3.8 0.7 349 18 23 255 20.7 0 21.1 20.5 07/01/2005 17:40:00 2.6 0.6 4.2 1.5 2.3 0.6 3.8 0.7 2 0.8 4.2 0.4 345 13 325 255 20.4 0.2 21.1 20 07/01/2005 17:50:00 2.3 0.6 3.8 0.4 2 0.6 3.4 0.4 1.5 0.8 3.8 0.4 341 17 314 255 19.5 0.2 20.3 19.1 07/01/2005 18:00:00 2.1 0.7 4.2 0.4 2 0.7 4.2 0.4 1.5 0.7 3.8 0.4 305 33 286 255 19.4 0.2 20 19.1 07/01/2005 18:10:00 2 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.5 0.8 3.8 0.4 324 22 324 255 20.2 0.2 20.8 19.7 07/01/2005 18:20:00 2.6 0.5 3.8 1.1 2.2 0.5 3.8 0.4 2.1 0.7 3.8 0.4 340 15 315 255 20.6 0.1 21.1 20.5 07/01/2005 18:30:00 2.3 0.9 4.6 0.4 2.1 0.8 4.2 0.4 1.7 0.8 4.2 0.4 322 22 326 255 20.4 0.1 20.8 20 07/01/2005 18:40:00 2.2 0.5 3.4 1.1 1.9 0.5 3.4 0.7 1.8 0.6 3.4 0.4 321 19 300 255 19.9 0 20.3 19.7 07/01/2005 18:50:00 3.1 0.5 4.2 1.9 2.8 0.6 4.2 1.5 2.2 0.7 3.8 0.4 352 12 356 255 19.7 0 20 19.4 07/01/2005 19:00:00 2.8 0.5 3.8 1.5 2.5 0.6 4.2 0.7 1.7 0.7 3.4 0.4 347 12 343 255 19.3 0 19.7 19.1 07/01/2005 19:10:00 2.1 0.6 3.4 0.4 1.8 0.6 3 0.4 1.4 0.6 3 0.4 343 14 356 255 19 0 19.4 18.8 07/01/2005 19:20:00 2.2 0.7 3.4 0.7 2 0.7 3.4 0.4 1.5 0.8 3.4 0.4 355 15 338 255 18.9 0.1 19.4 18.5 07/01/2005 19:30:00 2.1 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1.5 0.8 3.4 0.4 336 11 326 255 18.4 0.1 19.1 18 07/01/2005 19:40:00 2 0.7 3.4 0.4 1.6 0.6 3 0.4 1.3 0.7 3 0.4 334 11 321 255 17.9 0 18.2 17.7 07/01/2005 19:50:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.6 0.4 323 22 347 255 17.8 0 18.2 17.7 07/01/2005 20:00:00 1.9 0.4 3 0.7 1.7 0.5 3 0.4 1.1 0.5 2.3 0.4 355 12 355 255 17.6 0 18.2 17.4 07/01/2005 20:10:00 2.1 0.5 3.4 1.1 1.9 0.5 3.4 0.7 1.3 0.6 2.6 0.4 6 12 7 255 17.3 0 17.4 17.1 07/01/2005 20:20:00 3.5 0.6 4.6 1.5 3.4 0.6 4.6 1.1 2.6 0.8 4.6 0.7 18 10 18 255 17.2 0 17.1 17.1 07/01/2005 20:30:00 3.3 0.6 4.6 1.5 3.1 0.6 4.6 1.1 2.5 0.8 4.2 0.7 24 9 25 255 17.1 0 17.1 16.8 07/01/2005 20:40:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.1 2.4 0.6 3.8 1.1 32 11 48 255 17.1 0.1 17.4 16.8 07/01/2005 20:50:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.2 0.6 3.8 0.7 27 10 14 255 17.1 0.1 17.4 16.8 07/01/2005 21:00:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 2.4 0.5 3.8 1.1 32 11 58 255 16.4 0.2 16.8 16 07/01/2005 21:10:00 2.4 0.5 3.8 1.1 2.3 0.5 3.8 1.1 1.7 0.6 3.4 0.4 30 12 45 255 15.8 0 16.3 15.7 07/01/2005 21:20:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.6 0.5 3 0.4 33 13 40 255 15.5 0 15.7 15.2 07/01/2005 21:30:00 3.2 0.7 5.7 1.1 3.1 0.8 5.7 0.7 2.5 0.7 4.2 0.7 28 15 49 255 15 0 15.5 14.9 07/01/2005 21:40:00 3 0.8 5.3 1.1 2.9 0.9 5.7 0.4 2.4 0.8 4.2 0.7 36 15 29 255 14.9 0 15.5 14.9 07/01/2005 21:50:00 3.2 0.6 4.9 1.9 3 0.6 5.3 1.5 2.4 0.7 4.6 0.7 41 13 29 255 15.4 0.1 16 15.2 07/01/2005 22:00:00 2.6 0.5 3.8 1.5 2.4 0.6 3.8 1.1 1.8 0.5 3 0.7 50 15 18 255 15.7 0 16 15.5 07/01/2005 22:10:00 2.6 0.6 4.2 0.7 2.5 0.6 4.2 0.7 1.7 0.6 3 0.4 54 17 52 255 15.2 0.1 15.7 15.2 07/01/2005 22:20:00 2.2 0.5 3.8 1.1 2.1 0.6 3.8 0.4 1.6 0.5 3 0.4 55 15 51 255 14.8 0.1 15.2 14.4 07/01/2005 22:30:00 2 0.5 3.4 0.7 1.8 0.5 3.4 0.4 1.3 0.4 2.3 0.4 58 10 69 255 13.8 0.2 14.9 13.3 07/01/2005 22:40:00 1.6 0.4 3 0.4 1.3 0.5 2.6 0.4 0.9 0.4 1.9 0.4 66 12 53 255 13.2 0.1 13.8 13 07/01/2005 22:50:00 2 0.4 3 1.1 1.8 0.4 3 0.7 1.3 0.3 1.9 0.7 75 8 64 255 13 0 13.5 13 07/01/2005 23:00:00 1.9 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.3 0.3 2.3 0.4 75 7 64 255 13 0.1 13.5 12.7 07/01/2005 23:10:00 1.6 0.4 2.6 0.7 1.3 0.4 2.6 0.4 1 0.3 1.9 0.4 79 14 55 255 12.9 0.1 13.3 12.7 07/01/2005 23:20:00 1.6 0.3 2.3 0.7 1.3 0.4 2.3 0.4 1.1 0.3 1.9 0.4 97 8 99 255 12.9 0 13.3 12.7 07/01/2005 23:30:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1 0.3 1.9 0.4 96 9 93 255 12.8 0 13.3 12.7 07/01/2005 23:40:00 1.6 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1 0.3 1.5 0.4 111 12 102 255 12.8 0 13.3 12.7 07/01/2005 23:50:00 1.5 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.5 0.4 2.6 0.7 138 15 162 255 12.8 0 13.3 12.7 07/02/2005 00:00:00 2.5 0.2 3 1.9 2.4 0.2 3 1.5 2.1 0.3 2.6 1.1 150 5 150 255 12.9 0.1 13.3 12.7 07/02/2005 00:10:00 2.8 0.3 3.4 1.9 2.7 0.3 3 1.9 2.2 0.4 3.4 1.1 149 7 153 255 13 0.1 13.5 12.7 07/02/2005 00:20:00 2.3 0.3 3 1.5 2.2 0.3 3 1.1 2 0.4 2.6 0.7 130 8 142 255 13.2 0 13.8 13 07/02/2005 00:30:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.6 2.6 0.4 37 86 284 255 13.1 0 13.5 13 07/02/2005 00:40:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 100 255 13.1 0.1 13.5 12.7 07/02/2005 00:50:00 1.3 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.9 0.4 1.5 0.4 87 11 89 255 12.9 0 13.3 12.7 07/02/2005 01:00:00 1.4 0.3 1.9 0.7 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 98 9 86 255 12.8 0 13.3 12.7 07/02/2005 01:10:00 1.7 0.2 2.3 0.7 1.4 0.3 1.9 0.4 1 0.4 1.9 0.4 105 9 102 255 12.7 0 13.3 12.5 07/02/2005 01:20:00 1.7 0.3 2.6 0.7 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 97 9 86 255 12.5 0 13 12.5 07/02/2005 01:30:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 0.9 0.5 2.3 0.4 90 6 87 255 12.5 0 12.7 12.5 07/02/2005 01:40:00 1.8 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1 0.6 2.6 0.4 66 11 73 255 12.3 0 12.5 12.2 07/02/2005 01:50:00 2.4 0.5 3.8 1.1 2.2 0.5 3.8 0.7 1.9 0.5 3 0.4 46 10 41 255 12.4 0 12.7 12.2 07/02/2005 02:00:00 1.4 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 2.6 0.4 45 12 49 255 12.8 0 12.7 12.7 07/02/2005 02:10:00 2.2 0.3 3 1.5 2 0.4 3 1.1 1.7 0.5 3 0.4 53 11 53 255 12.8 0 13 12.7 07/02/2005 02:20:00 1.5 0.4 2.6 0.7 1.2 0.5 2.6 0.4 1.1 0.4 1.9 0.4 45 14 68 255 12.8 0 12.7 12.7 07/02/2005 02:30:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 75 38 34 255 12.8 0 12.7 12.7 07/02/2005 02:40:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 132 41 52 255 12.6 0 12.7 12.5 07/02/2005 02:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 130 36 52 255 12.5 0 12.7 12.5 07/02/2005 03:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 195 23 198 255 12.4 0 12.7 12.5 07/02/2005 03:10:00 1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 169 9 175 255 12.4 0 12.5 12.2 07/02/2005 03:20:00 1 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 135 6 156 255 12.4 0 12.5 12.2 07/02/2005 03:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.5 0.4 152 17 129 255 12.3 0 12.7 12.2 07/02/2005 03:40:00 1.1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 1 0.4 1.5 0.4 155 6 157 255 12.3 0 12.7 12.2 07/02/2005 03:50:00 1.4 0.3 1.9 0.7 1 0.3 1.5 0.4 0.7 0.4 1.5 0.4 147 9 159 255 12.3 0 12.7 12.2 07/02/2005 04:00:00 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 110 20 129 255 12.3 0.1 12.7 12.2 07/02/2005 04:10:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 90 0 90 255 12.3 0.1 12.7 12.2 07/02/2005 04:20:00 1.7 0.5 2.3 0.7 1.4 0.5 2.3 0.4 1.4 0.4 2.3 0.4 139 17 148 255 12.4 0.1 12.7 12.2 07/02/2005 04:30:00 1.7 0.4 2.3 0.7 1.4 0.5 2.3 0.4 1.1 0.5 1.9 0.4 147 2 147 255 12.6 0 13 12.5 07/02/2005 04:40:00 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 137 11 147 255 12.7 0 13.3 12.7 07/02/2005 04:50:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 118 0 119 255 12.9 0 13.3 12.7 07/02/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 118 0 255 255 12.9 0.2 13.5 12.7 07/02/2005 05:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 113 22 28 255 13.2 0 13.5 13 07/02/2005 05:20:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 28 0 28 255 13.4 0.1 13.8 13.3 07/02/2005 05:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 28 255 13.8 0 14.4 13.5 07/02/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 255 255 14 0.1 14.6 13.8 07/02/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 255 255 14.4 0 14.9 14.4 07/02/2005 06:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 28 0 28 255 14.5 0 14.9 14.6 07/02/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 255 255 14.6 0 14.9 14.6 07/02/2005 06:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 28 0 28 255 14.6 0 14.9 14.6 07/02/2005 06:30:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.4 1.9 0.4 0 17 352 255 14.8 0 15.2 14.6 07/02/2005 06:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 8 90 248 255 14.8 0 15.2 14.9 07/02/2005 06:50:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 317 41 345 255 15 0 15.5 14.9 07/02/2005 07:00:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 349 10 341 255 15 0 15.7 14.9 07/02/2005 07:10:00 1.4 0.3 2.3 0.4 0.8 0.3 1.9 0.4 0.9 0.5 2.3 0.4 341 11 337 255 14.9 0 15.5 14.9 07/02/2005 07:20:00 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 2.3 0.4 340 12 337 255 15 0 15.7 14.9 07/02/2005 07:30:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 352 11 329 255 15.1 0.1 15.7 15.2 07/02/2005 07:40:00 1 0.4 1.9 0.4 0.7 0.3 1.9 0.4 0.6 0.4 1.5 0.4 354 14 12 255 15.2 0.1 15.7 15.2 07/02/2005 07:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 353 12 16 255 15.2 0 15.7 15.2 07/02/2005 08:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 325 26 289 255 15.4 0 16 15.2 07/02/2005 08:10:00 1.5 0.4 2.6 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 301 12 299 255 15.4 0 15.7 15.2 07/02/2005 08:20:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.3 0.6 2.6 0.4 293 13 311 255 15.5 0 15.7 15.5 07/02/2005 08:30:00 1.4 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.2 0.5 2.3 0.4 304 15 316 255 15.5 0 16 15.5 07/02/2005 08:40:00 1.5 0.6 3 0.4 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 333 22 351 255 15.7 0 16.3 15.5 07/02/2005 08:50:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 5 15 10 255 16.1 0 16.6 16 07/02/2005 09:00:00 0.9 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 328 15 356 255 16.1 0 16.6 16.3 07/02/2005 09:10:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.9 0.4 325 35 354 255 16.1 0 16.8 16 07/02/2005 09:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.9 0.5 2.3 0.4 293 45 327 255 16.7 0.1 17.1 16.3 07/02/2005 09:30:00 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 272 49 320 255 17 0 17.4 16.8 07/02/2005 09:40:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 315 26 333 255 17.3 0 17.4 17.1 07/02/2005 09:50:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.6 2.6 0.4 338 39 302 255 17.7 0 18 17.4 07/02/2005 10:00:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 338 36 345 255 17.7 0 18 17.4 07/02/2005 10:10:00 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.2 0.5 2.3 0.4 342 38 15 255 18.1 0 18.5 17.7 07/02/2005 10:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1 0.4 1.5 0.4 279 29 260 255 18.3 0 18.5 18 07/02/2005 10:30:00 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 4 56 32 255 18.2 0 18.8 18 07/02/2005 10:40:00 1 0.6 3.4 0.4 0.8 0.6 3 0.4 1 0.5 2.3 0.4 24 45 324 255 18.7 0.2 19.4 18.2 07/02/2005 10:50:00 1.9 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.8 0.5 3 0.7 354 12 345 255 19.2 0 19.7 19.1 07/02/2005 11:00:00 1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 1 0.6 2.3 0.4 6 29 14 255 19 0 19.4 18.8 07/02/2005 11:10:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.1 0.4 334 39 3 255 19 0 19.4 18.5 07/02/2005 11:20:00 1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.8 0.6 2.3 0.4 0 49 352 255 19.7 0.1 20.3 19.1 07/02/2005 11:30:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 359 30 312 255 19.7 0.2 20.3 19.4 07/02/2005 11:40:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 274 94 198 255 19.5 0.1 20 19.4 07/02/2005 11:50:00 1.1 0.6 2.6 0.4 0.9 0.6 3 0.4 1 0.4 2.3 0.4 230 32 196 255 19.4 0.2 20 18.8 07/02/2005 12:00:00 1 0.6 2.6 0.4 0.8 0.5 2.6 0.4 0.8 0.5 2.6 0.4 220 20 253 255 19 0 19.4 18.8 07/02/2005 12:10:00 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 256 53 252 255 19.4 0 19.4 19.1 07/02/2005 12:20:00 1.1 0.7 3 0.4 1 0.7 3 0.4 1 0.8 2.6 0.4 226 56 225 255 19.4 0 20 19.1 07/02/2005 12:30:00 1.9 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.7 0.9 4.2 0.4 244 28 263 255 19.5 0.1 20.3 19.1 07/02/2005 12:40:00 1.9 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.6 0.7 3.4 0.4 206 30 195 255 19.5 0.1 20.3 19.1 07/02/2005 12:50:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1.6 0.6 3 0.4 213 20 194 255 19.2 0.1 19.7 18.8 07/02/2005 13:00:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 159 23 194 255 19.5 0 20 19.1 07/02/2005 13:10:00 0.5 0.4 1.9 0.4 0.5 0.3 2.3 0.4 0.6 0.4 2.3 0.4 125 90 241 255 19.4 0 20 19.1 07/02/2005 13:20:00 1.5 0.8 3.8 0.4 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 209 32 212 255 20.2 0.2 20.8 19.4 07/02/2005 13:30:00 1.7 0.9 3.4 0.4 1.6 0.9 3.8 0.4 1.3 0.8 3.4 0.4 201 28 276 255 19.9 0.2 20.5 19.4 07/02/2005 13:40:00 1.1 0.7 3.4 0.4 0.9 0.7 3.8 0.4 1 0.6 3 0.4 210 58 214 255 19.4 0 20 19.1 07/02/2005 13:50:00 1.4 0.5 3 0.4 1.2 0.6 2.6 0.4 1.4 0.6 3 0.4 146 43 197 255 19.2 0 19.7 19.1 07/02/2005 14:00:00 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.8 0.4 2.3 0.4 68 21 68 255 19.2 0 19.7 19.1 07/02/2005 14:10:00 1.3 0.8 3 0.4 1.2 0.8 3 0.4 1.1 0.7 3.4 0.4 53 47 30 255 19.7 0.4 20.8 19.4 07/02/2005 14:20:00 1.5 0.6 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.4 2.3 0.4 51 26 25 255 20.5 0 21.1 20.5 07/02/2005 14:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 37 36 10 255 20.4 0 21.1 20.3 07/02/2005 14:40:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 8 29 329 255 20.4 0 20.8 20.3 07/02/2005 14:50:00 1 0.7 3 0.4 0.9 0.6 2.3 0.4 1 0.6 2.6 0.4 113 39 208 255 20.3 0.2 20.8 20 07/02/2005 15:00:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 214 14 238 255 21 0.3 22.3 20.5 07/02/2005 15:10:00 1.8 0.8 3.8 0.4 1.7 0.9 3.8 0.4 1.5 0.7 3.8 0.4 36 53 19 255 22.7 0.4 23.5 22 07/02/2005 15:20:00 2.7 0.6 3.8 0.7 2.6 0.6 3.8 0.7 2.4 0.7 3.8 0.4 43 20 69 255 22.7 0.1 23.2 22.3 07/02/2005 15:30:00 1.8 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.7 0.7 3.4 0.4 353 38 293 255 22.7 0 23.2 22.6 07/02/2005 15:40:00 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 79 94 349 255 22.5 0.1 23.2 22.3 07/02/2005 15:50:00 2 0.8 3.8 0.4 1.9 0.8 4.2 0.4 1.6 0.6 3 0.4 22 72 253 255 22.9 0.2 23.5 22.6 07/02/2005 16:00:00 1.8 1 4.6 0.4 1.6 1 4.9 0.4 1.5 0.9 3.8 0.4 314 29 267 255 22.7 0.2 23.5 22.3 07/02/2005 16:10:00 3.1 1 6.1 0.7 2.8 1 5.7 0.7 2.6 1 4.9 0.4 324 21 345 255 23.1 0.3 23.8 22.3 07/02/2005 16:20:00 2.6 0.6 3.8 0.4 2.4 0.7 3.8 0.4 2.1 0.8 4.2 0.4 344 27 321 255 23.5 0.3 23.8 22.9 07/02/2005 16:30:00 2.6 0.7 4.9 0.4 2.5 0.7 4.9 0.4 1.8 0.8 4.6 0.4 2 24 6 255 24 0 24.4 23.8 07/02/2005 16:40:00 1.6 0.8 3.8 0.4 1.4 0.8 3.4 0.4 1.3 0.7 3.8 0.4 296 45 298 255 23.7 0 24.1 23.5 07/02/2005 16:50:00 2.4 1 5.3 0.4 2.3 1 5.3 0.4 2.1 0.8 4.6 0.4 293 41 280 255 23.3 0 23.5 22.9 07/02/2005 17:00:00 2.7 0.6 4.6 1.5 2.6 0.7 4.6 1.1 2.3 0.7 4.6 0.7 267 17 276 255 22.2 0.6 23.2 21.4 07/02/2005 17:10:00 1.8 1 4.6 0.4 1.6 1.1 4.6 0.4 1.5 0.9 4.2 0.4 13 79 30 255 21.5 0.1 21.7 21.1 07/02/2005 17:20:00 3.2 0.9 5.3 0.7 3 1 4.9 0.4 2.4 1 4.9 0.4 12 22 1 255 21.3 0 21.7 21.1 07/02/2005 17:30:00 3.2 0.7 4.9 1.9 3.1 0.7 4.9 1.1 2.5 0.8 5.3 0.7 12 17 18 255 21.6 0.1 22 21.1 07/02/2005 17:40:00 3.4 0.7 5.3 1.9 3.3 0.7 5.3 1.9 2.9 0.8 5.3 1.1 28 13 25 255 21.9 0 22 21.7 07/02/2005 17:50:00 3.1 0.6 4.9 1.5 2.9 0.7 4.6 0.7 2.6 0.8 4.6 0.4 23 12 17 255 21.5 0.1 22 21.1 07/02/2005 18:00:00 3.3 0.6 4.6 1.9 3.2 0.6 4.9 1.5 2.6 0.8 4.6 0.7 30 18 22 255 21 0 21.7 20.8 07/02/2005 18:10:00 3.7 0.6 5.3 1.9 3.6 0.7 5.3 1.1 2.9 0.9 4.9 0.7 19 13 18 255 20.8 0.1 21.1 20.5 07/02/2005 18:20:00 3.2 0.9 4.9 1.5 3.1 0.9 5.3 0.7 2.5 1.1 4.9 0.4 21 13 27 255 20.5 0 21.1 20.3 07/02/2005 18:30:00 3.2 0.6 4.6 1.5 3.1 0.7 4.9 1.1 2 1 4.2 0.4 6 13 28 255 20.5 0 20.5 20.5 07/02/2005 18:40:00 3.6 1 5.7 0.7 3.5 1.1 5.7 0.4 2.5 1 4.6 0.4 1 18 12 255 20.5 0 20.5 20.3 07/02/2005 18:50:00 3.4 0.8 5.3 1.5 3.3 0.8 5.3 1.1 2.5 1 4.9 0.4 13 14 10 255 20.5 0 20.8 20.5 07/02/2005 19:00:00 3.5 1 5.3 0.7 3.4 1 5.3 0.4 2.6 1 4.9 0.4 11 13 23 255 20.3 0 20.5 20 07/02/2005 19:10:00 3.1 0.6 4.2 1.1 3 0.7 4.2 0.7 2 0.8 3.8 0.4 8 15 10 255 19.9 0.1 20.5 19.4 07/02/2005 19:20:00 3.2 0.6 4.6 1.5 3.1 0.6 4.6 1.1 2.1 0.8 3.8 0.4 10 12 1 255 19.7 0.2 20.3 19.4 07/02/2005 19:30:00 2.5 0.5 4.2 1.5 2.2 0.6 4.2 1.1 1.8 0.8 3.4 0.4 334 24 340 255 19.2 0.1 19.7 19.1 07/02/2005 19:40:00 3 1 5.3 1.1 2.6 1 5.3 0.4 2.4 0.8 4.9 0.7 339 19 343 255 19 0 19.4 18.8 07/02/2005 19:50:00 3.3 0.7 5.3 1.9 3.1 0.8 4.9 1.5 2.3 0.8 4.2 0.4 353 13 4 255 18.7 0 19.4 18.5 07/02/2005 20:00:00 2.7 0.6 4.9 1.1 2.5 0.7 4.6 0.7 1.8 0.9 3.8 0.4 6 15 16 255 18.3 0 18.8 18 07/02/2005 20:10:00 2.3 0.7 4.6 0.7 2 0.9 4.6 0.4 1.6 0.7 3.8 0.4 354 20 1 255 18 0 18.2 18 07/02/2005 20:20:00 2 0.6 3.4 0.4 1.8 0.7 3 0.4 1.4 0.7 3 0.4 349 19 10 255 17.8 0 18 17.7 07/02/2005 20:30:00 2.2 0.8 4.2 0.4 1.9 0.9 3.8 0.4 1.4 0.8 3.8 0.4 357 16 15 255 17.8 0 18 17.7 07/02/2005 20:40:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 282 64 12 255 17.8 0 18 17.7 07/02/2005 20:50:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 246 72 275 255 18.1 0 18.2 17.7 07/02/2005 21:00:00 1.9 0.7 3 0.4 1.7 0.8 3 0.4 1.5 0.7 3 0.4 17 19 23 255 18.1 0 18.2 18 07/02/2005 21:10:00 2 0.4 3 1.1 1.7 0.5 3 0.7 1.5 0.6 2.6 0.4 5 11 4 255 17.9 0 18 17.7 07/02/2005 21:20:00 2 0.5 3.4 0.7 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 11 15 24 255 17.8 0 18 17.7 07/02/2005 21:30:00 2.3 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.6 0.9 3.8 0.4 20 14 14 255 17.5 0.1 17.7 17.1 07/02/2005 21:40:00 2.2 0.6 3.4 0.4 2 0.6 3 0.4 1.7 0.8 3.4 0.4 23 10 34 255 17.1 0 17.4 16.8 07/02/2005 21:50:00 2.6 0.6 3.8 0.7 2.4 0.7 3.8 0.4 1.7 0.8 3 0.4 18 9 15 255 16.8 0 17.1 16.6 07/02/2005 22:00:00 1.8 0.4 2.6 0.4 1.5 0.5 2.3 0.4 1.5 0.6 2.6 0.4 35 11 37 255 16.5 0 16.8 16.6 07/02/2005 22:10:00 1.3 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 24 10 10 255 16.4 0.1 16.8 16.3 07/02/2005 22:20:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 1.2 0.7 2.6 0.4 57 10 55 255 16.1 0 16.6 16 07/02/2005 22:30:00 2.2 0.4 3.4 1.5 2 0.5 3 0.7 1.7 0.6 3.4 0.4 35 10 49 255 16 0 16.6 15.7 07/02/2005 22:40:00 1.4 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 19 11 27 255 15.7 0 16.3 15.7 07/02/2005 22:50:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 25 12 15 255 15.7 0 16 15.5 07/02/2005 23:00:00 2.2 0.4 3 1.1 2 0.5 3 0.7 1.5 0.6 2.6 0.4 20 11 21 255 15.5 0 16 15.5 07/02/2005 23:10:00 1.9 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.4 24 9 44 255 15.4 0.1 15.7 15.2 07/02/2005 23:20:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1 0.6 2.6 0.4 45 22 25 255 15.3 0.1 15.7 15.2 07/02/2005 23:30:00 1.8 0.5 3.4 0.7 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 72 12 76 255 15.2 0.2 15.7 14.9 07/02/2005 23:40:00 2.1 0.7 3.8 0.7 1.9 0.8 3.4 0.4 1.5 0.6 3 0.4 60 22 50 255 14.9 0.2 15.5 14.6 07/02/2005 23:50:00 3.8 0.6 5.3 1.9 3.7 0.6 5.3 1.9 3 0.7 4.9 1.5 38 10 31 255 14.2 0.3 15.2 13.5 07/03/2005 00:00:00 3.6 0.7 4.9 1.9 3.5 0.7 5.3 1.9 2.9 0.7 4.6 1.1 36 12 28 255 13.5 0.1 14.1 13.3 07/03/2005 00:10:00 2.3 0.9 4.2 0.4 2 1 4.2 0.4 1.8 0.9 3.8 0.4 39 18 27 255 13.3 0 13.5 13 07/03/2005 00:20:00 1.7 0.6 3.4 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 61 18 60 255 13.1 0.1 13.5 12.7 07/03/2005 00:30:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1.2 0.5 1.9 0.4 58 14 84 255 12.9 0 13.3 12.7 07/03/2005 00:40:00 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 39 14 22 255 12.8 0 13.3 12.7 07/03/2005 00:50:00 2 0.4 3.4 0.7 1.8 0.5 3.4 0.4 1.6 0.5 3 0.4 42 15 32 255 12.8 0 13.3 12.7 07/03/2005 01:00:00 1.8 0.5 3 0.7 1.5 0.6 3 0.4 1.3 0.6 3 0.4 44 20 63 255 12.8 0 13.3 12.7 07/03/2005 01:10:00 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 1 0.5 2.6 0.4 58 23 63 255 12.8 0 13 12.7 07/03/2005 01:20:00 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 61 17 60 255 12.8 0 12.7 12.7 07/03/2005 01:30:00 1.3 0.5 2.6 0.4 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 39 16 19 255 12.8 0 12.7 12.7 07/03/2005 01:40:00 1.8 0.4 3 1.1 1.5 0.4 2.6 0.4 1.4 0.5 2.6 0.4 32 14 21 255 12.8 0 13 12.7 07/03/2005 01:50:00 1.8 0.4 3 0.7 1.6 0.5 3 0.4 1.2 0.6 2.6 0.4 24 6 28 255 12.8 0 13 12.7 07/03/2005 02:00:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.5 1.9 0.5 3 0.7 22 9 13 255 12.8 0 13 12.7 07/03/2005 02:10:00 2.2 0.4 3 1.1 2 0.4 3 0.7 1.7 0.5 2.6 0.4 29 10 14 255 12.8 0 12.7 12.7 07/03/2005 02:20:00 2.2 0.4 3 1.5 1.9 0.5 3 0.7 1.7 0.5 3 0.7 30 11 31 255 12.9 0 13.3 12.7 07/03/2005 02:30:00 2.2 0.4 3.4 1.5 2 0.4 3 1.1 1.9 0.5 3 0.4 33 10 40 255 12.9 0 13.3 12.7 07/03/2005 02:40:00 1.8 0.3 2.6 0.7 1.5 0.4 2.3 0.4 1.4 0.5 2.6 0.4 31 11 31 255 12.8 0 13.3 12.7 07/03/2005 02:50:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 42 13 46 255 12.9 0 13.3 12.7 07/03/2005 03:00:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 46 15 66 255 12.9 0 13.3 12.7 07/03/2005 03:10:00 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 46 13 28 255 12.8 0 13.3 12.7 07/03/2005 03:20:00 1.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 38 15 43 255 12.8 0 13.3 12.7 07/03/2005 03:30:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 45 12 35 255 12.8 0 13 12.7 07/03/2005 03:40:00 1 0.5 2.6 0.4 0.7 0.4 2.3 0.4 0.7 0.5 1.9 0.4 39 12 49 255 12.8 0 13 12.7 07/03/2005 03:50:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 62 13 30 255 12.7 0 13 12.7 07/03/2005 04:00:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 55 14 35 255 12.7 0 13 12.7 07/03/2005 04:10:00 1.1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 0.5 0.3 1.5 0.4 72 13 54 255 12.7 0 13 12.7 07/03/2005 04:20:00 1.7 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 68 13 52 255 12.7 0 13 12.7 07/03/2005 04:30:00 2.1 0.4 3 1.1 1.8 0.5 2.6 0.7 1.7 0.5 2.6 0.4 47 13 60 255 12.8 0 13 12.7 07/03/2005 04:40:00 2.1 0.7 3.4 0.4 1.8 0.8 3 0.4 1.6 0.8 3 0.4 42 14 43 255 12.8 0 12.7 12.7 07/03/2005 04:50:00 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 59 32 85 255 12.8 0 13 12.7 07/03/2005 05:00:00 1.9 0.5 3 0.4 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 57 12 63 255 12.8 0 13 12.7 07/03/2005 05:10:00 1.7 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1 0.6 2.3 0.4 66 16 70 255 12.9 0 13.3 12.7 07/03/2005 05:20:00 1.9 0.5 3.4 0.7 1.5 0.6 3 0.4 1.4 0.5 2.6 0.4 60 15 39 255 13.1 0 13 13 07/03/2005 05:30:00 2.1 0.4 3 1.1 1.9 0.5 3 1.1 1.4 0.6 2.6 0.4 48 15 62 255 13.1 0 13.3 13 07/03/2005 05:40:00 1.7 0.4 2.6 0.7 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 33 13 35 255 13.3 0 13.3 13 07/03/2005 05:50:00 1.6 0.6 3 0.4 1.3 0.7 2.6 0.4 1.1 0.6 2.6 0.4 46 11 55 255 13.4 0 13.5 13.3 07/03/2005 06:00:00 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 49 18 63 255 13.4 0 13.5 13.3 07/03/2005 06:10:00 1.7 0.6 3 0.4 1.4 0.6 3 0.4 1.2 0.6 3 0.4 54 19 29 255 13.5 0 13.5 13.3 07/03/2005 06:20:00 2.7 0.4 3.8 1.9 2.5 0.5 3.8 1.5 2.2 0.5 3.4 1.1 42 12 48 255 13.5 0 13.8 13.3 07/03/2005 06:30:00 2.5 0.6 3.8 1.1 2.3 0.7 3.8 0.7 2.2 0.5 3.8 0.7 38 16 32 255 13.5 0 13.8 13.5 07/03/2005 06:40:00 2.6 0.6 4.6 1.1 2.3 0.7 4.2 0.4 1.8 0.8 4.2 0.4 44 18 38 255 13.9 0 14.4 13.5 07/03/2005 06:50:00 2.7 0.5 3.8 1.5 2.5 0.5 3.8 1.1 2.1 0.5 3.4 1.1 32 12 48 255 13.9 0 14.6 13.8 07/03/2005 07:00:00 2.5 0.6 3.8 0.7 2.2 0.6 3.8 0.7 2.1 0.6 3.4 0.4 34 14 20 255 14.1 0.1 14.6 13.8 07/03/2005 07:10:00 1.9 0.6 3 0.4 1.7 0.6 2.6 0.4 1.4 0.6 2.6 0.4 41 22 26 255 14.1 0.1 14.6 13.8 07/03/2005 07:20:00 2.1 0.6 3.8 0.7 1.9 0.7 3.8 0.4 1.6 0.7 3 0.4 42 17 43 255 14.1 0 14.6 13.8 07/03/2005 07:30:00 2 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.6 0.8 3 0.4 37 18 37 255 14.1 0.1 14.6 13.8 07/03/2005 07:40:00 2.2 0.5 3.4 0.7 1.9 0.6 3 0.4 1.6 0.6 3 0.4 46 12 35 255 14.3 0 14.6 14.1 07/03/2005 07:50:00 1.9 0.4 3 0.7 1.5 0.5 3 0.4 1.2 0.5 2.3 0.4 50 15 39 255 14.4 0 14.9 14.4 07/03/2005 08:00:00 1.9 0.5 3.4 0.7 1.7 0.5 3.4 0.4 1.5 0.5 2.6 0.4 41 19 22 255 14.6 0.1 15.2 14.6 07/03/2005 08:10:00 2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 1.4 0.7 3 0.4 49 20 18 255 14.8 0 15.5 14.9 07/03/2005 08:20:00 2.3 0.5 3.4 1.1 2.1 0.5 3 0.7 1.9 0.6 3.8 0.4 57 11 62 255 14.9 0 15.5 14.6 07/03/2005 08:30:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 0.4 2.1 0.7 3.4 0.4 52 14 46 255 14.8 0 15.5 14.6 07/03/2005 08:40:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 0.7 2.5 0.5 3.8 1.1 48 20 56 255 15.4 0.3 16.3 15.2 07/03/2005 08:50:00 2.2 0.5 3.4 0.4 2.1 0.5 3 0.4 1.9 0.6 3 0.4 49 17 62 255 15.9 0 16.6 15.7 07/03/2005 09:00:00 2.2 0.5 3 0.7 2 0.5 3 0.4 1.7 0.5 2.6 0.4 56 12 32 255 15.7 0 16 15.7 07/03/2005 09:10:00 2 0.5 3 0.7 1.8 0.6 3 0.4 1.5 0.7 3 0.4 33 21 46 255 16.4 0.2 17.1 16 07/03/2005 09:20:00 2.1 0.5 3.4 0.4 1.9 0.6 3 0.4 1.8 0.6 3.4 0.4 53 20 69 255 17.5 0.2 18 16.8 07/03/2005 09:30:00 2.1 0.6 3.8 0.4 1.9 0.7 3.4 0.4 1.8 0.8 3.8 0.4 44 15 43 255 17.6 0 17.7 17.4 07/03/2005 09:40:00 2.6 0.6 4.2 1.5 2.5 0.6 4.2 1.1 2.2 0.6 3.8 0.4 51 16 39 255 17.9 0 18.2 17.4 07/03/2005 09:50:00 2.1 0.7 3.4 0.4 1.9 0.8 3.4 0.4 1.9 0.8 3.4 0.4 45 19 46 255 17.9 0 18.2 17.7 07/03/2005 10:00:00 2 0.5 3.4 0.7 1.7 0.6 3 0.4 1.6 0.6 2.6 0.4 59 13 71 255 18.2 0 18.2 18 07/03/2005 10:10:00 2.5 0.5 3.8 0.7 2.3 0.6 3.8 0.4 2.2 0.6 3.4 0.4 26 13 20 255 18.4 0 18.5 18.2 07/03/2005 10:20:00 2.3 0.5 3.4 1.1 2.1 0.5 3.4 0.4 1.8 0.6 3 0.4 21 22 1 255 18.8 0.2 19.7 18.5 07/03/2005 10:30:00 2.5 0.6 4.6 1.1 2.3 0.7 4.6 0.4 2 0.8 4.2 0.4 20 19 15 255 19.8 0.3 20.5 19.4 07/03/2005 10:40:00 2.7 0.6 4.2 1.5 2.6 0.6 4.2 1.1 2.2 0.6 3.8 0.7 16 22 4 255 20.3 0.2 21.1 20 07/03/2005 10:50:00 2 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.5 0.7 4.2 0.4 351 43 16 255 20.6 0.1 21.1 20.5 07/03/2005 11:00:00 2.3 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.9 0.7 3.8 0.4 9 21 35 255 20.3 0.1 21.1 20 07/03/2005 11:10:00 1.9 0.5 3.4 0.7 1.5 0.6 3 0.4 1.5 0.6 3 0.4 320 23 314 255 20.5 0 20.8 20.3 07/03/2005 11:20:00 1.8 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.4 0.7 3.4 0.4 12 41 5 255 20.8 0.2 21.1 20.3 07/03/2005 11:30:00 1.5 0.7 3 0.4 1.3 0.7 3 0.4 1.5 0.6 3 0.4 59 41 38 255 20.2 0.3 20.5 19.4 07/03/2005 11:40:00 1.2 0.6 3 0.4 0.9 0.6 3 0.4 1.1 0.6 2.6 0.4 92 49 76 255 19.2 0 19.4 19.1 07/03/2005 11:50:00 2.1 0.6 3.4 0.7 1.8 0.7 3.8 0.4 1.8 0.6 3.4 0.4 223 22 183 255 19 0 19.4 18.8 07/03/2005 12:00:00 1.8 0.7 3.4 0.4 1.5 0.8 3 0.4 1.3 0.8 3 0.4 236 17 229 255 18.7 0 19.4 18.5 07/03/2005 12:10:00 1.9 0.7 3.4 0.4 1.7 0.8 3.8 0.4 1.7 0.7 3.4 0.4 241 16 237 255 19 0.2 19.7 18.5 07/03/2005 12:20:00 1.9 0.9 3.8 0.4 1.7 0.9 3.4 0.4 1.5 0.9 3.4 0.4 254 27 236 255 19 0.1 19.4 18.8 07/03/2005 12:30:00 2.5 0.6 3.8 1.1 2.3 0.7 3.8 0.4 1.9 0.8 3.4 0.4 248 17 250 255 19 0.1 19.4 18.8 07/03/2005 12:40:00 2.2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 249 19 257 255 19 0.1 19.4 18.8 07/03/2005 12:50:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1.4 0.6 3 0.4 238 22 253 255 19.2 0.2 20 18.8 07/03/2005 13:00:00 1.7 0.7 3 0.4 1.5 0.8 3 0.4 1.5 0.7 3 0.4 284 41 265 255 19.5 0.1 20 19.4 07/03/2005 13:10:00 1.9 0.9 3.4 0.4 1.6 0.9 3 0.4 1.5 0.9 3 0.4 287 22 260 255 19.7 0.1 20.5 19.4 07/03/2005 13:20:00 1.7 0.6 3 0.4 1.4 0.7 3 0.4 1.4 0.6 3 0.4 273 35 273 255 20.1 0.2 20.8 19.4 07/03/2005 13:30:00 2.3 0.7 4.6 0.7 2.1 0.8 4.6 0.4 1.7 0.8 3.4 0.4 276 30 305 255 20.3 0 20.8 20 07/03/2005 13:40:00 2 0.7 3.8 0.4 1.8 0.7 3.4 0.4 1.6 0.7 3.4 0.4 252 45 226 255 20 0 20.5 20 07/03/2005 13:50:00 2.3 0.8 3.8 0.4 2.2 0.8 3.8 0.4 2 0.9 3.4 0.4 252 22 244 255 20.1 0.1 20.5 20 07/03/2005 14:00:00 2.1 0.6 3.8 0.7 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 276 24 296 255 20.1 0 20.5 19.7 07/03/2005 14:10:00 1.9 0.7 3.8 0.4 1.7 0.8 3.8 0.4 1.7 0.8 3.8 0.4 263 28 255 255 20.3 0.2 21.1 19.7 07/03/2005 14:20:00 2.9 1 4.9 0.4 2.7 1.1 4.9 0.4 2.4 1 4.9 0.7 269 26 277 255 21 0.2 21.7 20.5 07/03/2005 14:30:00 2.9 1 4.9 0.7 2.6 1.1 4.9 0.4 2.4 0.9 4.9 0.4 276 41 15 255 21.3 0.2 21.7 21.1 07/03/2005 14:40:00 2.3 1 4.9 0.4 2.1 1 4.6 0.4 1.8 1 4.6 0.4 267 53 269 255 21.3 0.1 21.7 21.1 07/03/2005 14:50:00 2.9 1 5.3 1.1 2.8 1 5.3 0.4 2.4 1.1 5.3 0.4 265 27 273 255 21.1 0 21.4 20.8 07/03/2005 15:00:00 2.7 0.8 4.9 0.7 2.5 0.8 4.6 0.4 2.1 0.8 4.2 0.4 240 29 282 255 21.5 0 21.7 21.1 07/03/2005 15:10:00 2.8 1 4.9 0.4 2.6 1 4.9 0.4 2.2 0.9 4.6 0.4 273 33 280 255 21.1 0 21.4 20.8 07/03/2005 15:20:00 2.3 1.2 6.1 0.4 2.2 1.3 5.3 0.4 1.8 1 4.6 0.4 274 51 266 255 21.7 0.2 22.3 21.1 07/03/2005 15:30:00 2.8 1 5.3 0.7 2.7 1.1 5.3 0.7 2.5 1.1 5.7 0.4 241 27 253 255 21.6 0 21.7 21.7 07/03/2005 15:40:00 3.7 0.8 5.7 1.1 3.6 0.8 5.7 1.5 3 0.9 5.3 1.1 278 21 274 255 21.1 0.2 21.7 20.8 07/03/2005 15:50:00 2.6 0.9 5.3 0.4 2.5 0.9 4.9 0.4 2.1 0.8 4.9 0.4 269 38 246 255 21.2 0.3 22 20.8 07/03/2005 16:00:00 2 1 4.6 0.4 1.8 1 4.6 0.4 1.7 0.7 4.2 0.4 272 36 315 255 21.9 0.3 22.9 21.7 07/03/2005 16:10:00 3.4 0.9 5.3 0.7 3.2 1 5.3 0.7 2.4 1 4.9 0.4 272 29 281 255 22.1 0.3 22.9 21.7 07/03/2005 16:20:00 3.4 0.9 6.1 1.1 3.4 1 6.5 0.7 3 0.9 6.5 0.7 256 24 252 255 21.5 0 22 21.1 07/03/2005 16:30:00 2.6 0.8 4.6 0.7 2.5 0.8 4.6 0.7 2 0.8 4.2 0.4 238 22 266 255 21.3 0 21.4 21.1 07/03/2005 16:40:00 3.2 1 6.1 1.1 3.1 1.1 6.1 1.1 2.7 1 5.7 0.4 253 19 246 255 21.1 0 21.1 20.8 07/03/2005 16:50:00 2.9 1 5.7 0.7 2.9 1.1 5.7 0.4 2.3 1.2 5.7 0.4 269 24 286 255 21 0 21.4 20.8 07/03/2005 17:00:00 4.1 0.8 6.1 2.3 3.9 0.9 5.7 0.7 3.4 1.1 6.5 0.4 290 19 312 255 20.5 0 21.1 20.5 07/03/2005 17:10:00 2.9 0.9 4.9 0.4 2.8 0.9 4.9 0.4 2.4 1 4.6 0.4 269 26 281 255 20.4 0 20.5 20.3 07/03/2005 17:20:00 2.6 1 5.3 0.4 2.5 1.1 5.3 0.4 2.2 1 5.7 0.4 288 20 255 255 20.5 0 21.1 20.3 07/03/2005 17:30:00 3 1.2 6.8 0.4 2.8 1.3 6.8 0.4 2.4 1.1 5.7 0.4 292 19 267 255 20.4 0 20.8 20.3 07/03/2005 17:40:00 3.3 1.2 6.8 0.7 3.2 1.3 6.1 0.4 2.7 1.2 6.1 0.4 288 24 265 255 20.3 0.1 20.8 20 07/03/2005 17:50:00 3.3 1 5.3 0.7 3.1 1 5.3 0.4 2.6 1 5.3 0.4 284 26 275 255 20.5 0 21.1 20 07/03/2005 18:00:00 3.4 1 6.8 0.7 3.3 1.1 6.1 0.4 3 0.9 5.3 1.1 282 18 291 255 20.5 0 21.1 20.3 07/03/2005 18:10:00 3.5 0.8 6.5 1.9 3.4 0.8 6.1 1.5 2.9 0.7 4.9 1.5 292 20 301 255 20.3 0.1 20.8 20 07/03/2005 18:20:00 3.1 0.9 5.7 0.7 2.9 1 5.3 0.4 2.3 1 5.3 0.4 292 24 308 255 20.2 0.1 20.5 20 07/03/2005 18:30:00 3.3 1.1 6.1 0.7 3.3 1.1 6.1 0.7 2.6 1.1 5.3 0.4 278 24 255 255 20 0 20.5 20 07/03/2005 18:40:00 2.9 1 5.3 0.4 2.8 1.1 5.3 0.4 2.1 1.1 4.9 0.4 280 20 271 255 19.9 0 20.3 19.7 07/03/2005 18:50:00 3.9 0.9 6.5 1.5 3.7 0.9 6.1 1.5 2.9 0.9 4.9 0.7 285 17 255 255 19.7 0.1 20.3 19.4 07/03/2005 19:00:00 2.5 1.1 4.9 0.4 2.4 1.2 4.9 0.4 1.9 1.1 4.6 0.4 284 22 307 255 19.5 0 20 19.4 07/03/2005 19:10:00 2.2 0.9 4.2 0.4 1.9 1 4.2 0.4 1.7 1 4.6 0.4 284 21 300 255 19.4 0 19.4 19.1 07/03/2005 19:20:00 2.7 1.1 5.7 0.4 2.5 1.3 6.1 0.4 2.1 1.2 4.9 0.4 271 22 255 255 19.2 0 19.4 19.1 07/03/2005 19:30:00 2.8 0.9 5.7 0.7 2.7 1 5.7 0.4 2.1 1 4.9 0.4 267 23 271 255 19 0 19.1 18.8 07/03/2005 19:40:00 2.6 1 6.1 0.7 2.4 1.1 5.7 0.4 1.8 1 4.9 0.4 284 24 283 255 18.9 0 19.1 18.8 07/03/2005 19:50:00 3.3 1.1 6.5 0.4 3.2 1.3 6.5 0.4 2.6 1 5.3 0.4 270 23 257 255 18.8 0 18.8 18.5 07/03/2005 20:00:00 3.2 1.1 5.3 0.7 3 1.2 5.3 0.4 2.5 1 5.3 0.7 279 20 275 255 18.7 0 18.8 18.5 07/03/2005 20:10:00 2.7 0.8 4.6 0.7 2.6 0.9 4.6 0.7 2.1 0.8 4.2 0.7 281 26 287 255 18.6 0 18.8 18.2 07/03/2005 20:20:00 2 0.9 4.2 0.4 1.8 1 3.8 0.4 1.7 0.8 3.8 0.4 288 17 279 255 18.3 0 18.5 18.2 07/03/2005 20:30:00 1.3 0.8 3.8 0.4 1.1 0.8 3.8 0.4 0.9 0.7 3.4 0.4 281 58 274 255 18.2 0 18.2 18 07/03/2005 20:40:00 2.7 1 4.6 0.4 2.6 1.1 4.6 0.4 2.1 0.9 4.2 0.4 264 19 268 255 18 0 18.2 17.7 07/03/2005 20:50:00 2.1 0.6 3.8 0.4 1.9 0.7 3.8 0.4 1.7 0.6 3.8 0.4 270 24 284 255 17.8 0 18 17.7 07/03/2005 21:00:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.6 0.4 284 15 310 255 17.7 0 18 17.4 07/03/2005 21:10:00 1.9 0.4 3 1.1 1.6 0.4 2.6 0.7 1.5 0.5 3 0.4 291 11 294 255 17.4 0.1 17.7 17.1 07/03/2005 21:20:00 1.9 0.5 3 0.4 1.6 0.6 3 0.4 1.2 0.5 2.6 0.4 281 17 282 255 17.3 0 17.7 17.1 07/03/2005 21:30:00 2 0.6 3 0.7 1.7 0.7 3 0.4 1.5 0.6 3 0.4 284 15 272 255 17.3 0 17.7 17.1 07/03/2005 21:40:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 298 17 290 255 17.1 0 17.7 16.8 07/03/2005 21:50:00 1.8 0.5 3.4 0.7 1.6 0.7 3.4 0.4 1.2 0.5 2.6 0.4 288 12 281 255 16.8 0 17.4 16.6 07/03/2005 22:00:00 2.1 0.6 3.4 0.7 1.8 0.7 3 0.4 1.2 0.6 2.6 0.4 288 13 280 255 16.4 0.2 16.8 16 07/03/2005 22:10:00 1.3 0.4 3 0.7 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 296 11 269 255 15.9 0.1 16.8 15.7 07/03/2005 22:20:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 297 2 300 255 15.4 0.2 16 15.2 07/03/2005 22:30:00 1.1 0.2 1.5 0.7 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 295 0 295 255 15 0 15.7 14.6 07/03/2005 22:40:00 0.7 0.3 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.4 0.4 287 12 295 255 14.6 0 15.2 14.4 07/03/2005 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 270 255 14.3 0.1 14.9 14.1 07/03/2005 23:00:00 0.6 0.4 2.3 0.4 0.4 0.3 1.9 0.4 0.4 0.1 1.1 0.4 270 4 252 255 14 0 14.6 13.8 07/03/2005 23:10:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 255 24 239 255 13.9 0 14.6 13.8 07/03/2005 23:20:00 1.1 0.2 1.9 0.7 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 318 0 318 255 13.9 0 14.4 13.5 07/03/2005 23:30:00 1.3 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 318 0 318 255 13.7 0 14.4 13.5 07/03/2005 23:40:00 1.1 0.4 2.3 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 353 26 333 255 13.5 0.1 13.8 13.5 07/03/2005 23:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 13 0 13 255 13.5 0.1 13.8 13.5 07/04/2005 00:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 1 24 288 255 13.4 0 13.5 13.3 07/04/2005 00:10:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 273 10 281 255 13.3 0 13.5 13.3 07/04/2005 00:20:00 1.6 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.6 0.3 1.5 0.4 265 9 274 255 13.5 0 13.5 13.3 07/04/2005 00:30:00 1.3 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 259 6 256 255 13.5 0 13.5 13.5 07/04/2005 00:40:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 274 1 274 255 13.5 0 13.5 13.3 07/04/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 255 255 13.3 0 13.5 13.3 07/04/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 255 255 13.3 0 13.8 13 07/04/2005 01:10:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 274 0 274 255 13.3 0 13.5 13 07/04/2005 01:20:00 1.3 0.3 1.9 0.7 1 0.3 1.5 0.4 0.4 0.1 0.7 0.4 262 7 267 255 13.2 0 13.5 13 07/04/2005 01:30:00 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 255 0 255 255 13.2 0 13.5 13 07/04/2005 01:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 13.1 0.1 13.5 13 07/04/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 255 0 255 255 13.1 0.1 13.3 13 07/04/2005 02:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 13 0.2 13.3 12.7 07/04/2005 02:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 13 0.1 13.3 12.7 07/04/2005 02:20:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 311 32 329 255 13 0.1 13.3 12.7 07/04/2005 02:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 329 255 13.1 0 13.3 13 07/04/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 255 255 13.1 0 13.5 13 07/04/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 255 255 13.1 0.1 13.3 13 07/04/2005 03:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 324 15 280 255 13.1 0 13.5 13 07/04/2005 03:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 280 0 280 255 13.1 0 13.5 13 07/04/2005 03:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 322 7 302 255 13.1 0 13.5 13 07/04/2005 03:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 350 45 68 255 13.1 0 13.5 13 07/04/2005 03:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 89 5 68 255 13.1 0 13.3 13 07/04/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 255 255 13.1 0 13.3 13 07/04/2005 04:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 90 255 13.3 0 13.3 13 07/04/2005 04:10:00 0.6 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 158 35 184 255 13.3 0 13.5 13.3 07/04/2005 04:20:00 0.9 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 184 0 184 255 13.3 0 13.3 13.3 07/04/2005 04:30:00 1.2 0.3 1.9 0.4 1.1 0.2 1.9 0.7 0.9 0.2 1.5 0.4 176 9 170 255 13.3 0 13.3 13.3 07/04/2005 04:40:00 1.2 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.9 0.2 1.5 0.4 153 1 150 255 13.3 0 13.3 13.3 07/04/2005 04:50:00 1.8 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.4 0.3 1.9 0.7 144 8 153 255 13.4 0 13.5 13.3 07/04/2005 05:00:00 1.7 0.2 2.3 1.1 1.4 0.2 2.3 0.7 1.2 0.3 2.3 0.4 140 5 140 255 13.5 0 13.5 13.3 07/04/2005 05:10:00 1.6 0.2 2.3 1.1 1.3 0.2 1.9 0.7 1.1 0.2 1.5 0.4 145 4 152 255 13.7 0 13.8 13.5 07/04/2005 05:20:00 1.8 0.2 2.3 1.1 1.5 0.2 1.9 0.7 1.3 0.3 1.9 0.4 155 3 152 255 13.9 0 13.8 13.8 07/04/2005 05:30:00 1.5 0.3 2.3 0.7 1.3 0.2 1.9 0.7 1.1 0.3 1.9 0.4 165 6 156 255 13.9 0 14.4 13.8 07/04/2005 05:40:00 1.2 0.3 1.9 0.7 1 0.2 1.5 0.7 0.8 0.3 1.5 0.4 166 4 170 255 14 0 14.6 13.8 07/04/2005 05:50:00 1.7 0.3 2.3 1.1 1.4 0.4 2.3 0.4 1.3 0.3 2.3 0.7 156 5 161 255 14.1 0 14.6 14.1 07/04/2005 06:00:00 1.4 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 143 8 149 255 14.4 0 14.9 14.4 07/04/2005 06:10:00 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 123 4 121 255 14.6 0 15.2 14.6 07/04/2005 06:20:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 43 61 337 255 15 0.1 15.7 14.9 07/04/2005 06:30:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.5 0.4 337 0 337 255 15.2 0.2 15.7 15.2 07/04/2005 06:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 5 30 337 255 15.5 0 16 15.5 07/04/2005 06:50:00 1.2 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.9 0.6 2.3 0.4 3 16 343 255 15.7 0 16.3 15.7 07/04/2005 07:00:00 1 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 8 351 255 16.1 0.1 16.8 16 07/04/2005 07:10:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0 6 355 255 16.4 0.1 16.8 16.3 07/04/2005 07:20:00 1.4 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 346 22 326 255 16.6 0 16.8 16.6 07/04/2005 07:30:00 1.2 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.5 2.3 0.4 341 17 305 255 16.6 0 16.8 16.3 07/04/2005 07:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 4 4 9 255 16.7 0.1 17.1 16.6 07/04/2005 07:50:00 1.3 0.5 2.6 0.4 0.9 0.5 2.6 0.4 1.2 0.5 2.6 0.4 355 13 349 255 16.9 0 17.4 16.8 07/04/2005 08:00:00 1.8 0.4 2.6 0.4 1.6 0.5 2.6 0.4 1.6 0.5 3 0.4 40 16 30 255 16.8 0 17.4 16.8 07/04/2005 08:10:00 2 0.4 3 1.1 1.7 0.5 2.6 0.7 1.7 0.4 2.6 0.7 41 13 44 255 16.6 0 16.8 16.6 07/04/2005 08:20:00 1.8 0.3 2.6 1.1 1.5 0.3 2.3 0.7 1.8 0.3 2.6 0.7 32 8 26 255 16.5 0 16.8 16.6 07/04/2005 08:30:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.7 1.5 0.5 2.6 0.4 28 12 35 255 16.7 0 16.8 16.6 07/04/2005 08:40:00 2 0.5 3.4 0.7 1.7 0.5 3.4 0.4 1.8 0.5 2.6 0.4 42 19 75 255 17.1 0 17.4 16.8 07/04/2005 08:50:00 1.7 0.4 3 0.7 1.4 0.5 2.6 0.4 1.5 0.4 2.6 0.4 26 13 49 255 17.1 0 17.1 16.8 07/04/2005 09:00:00 1.5 0.3 2.3 0.4 1.2 0.4 1.9 0.4 1.1 0.5 1.9 0.4 13 9 10 255 17.4 0 17.7 17.1 07/04/2005 09:10:00 2 0.5 3 0.7 1.7 0.5 3 0.4 1.7 0.4 2.6 0.7 27 16 7 255 17.8 0 17.7 17.7 07/04/2005 09:20:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1.4 0.6 3 0.4 18 15 2 255 17.8 0 18 17.4 07/04/2005 09:30:00 1.7 0.4 3 0.7 1.3 0.5 3 0.4 1.2 0.5 2.3 0.4 0 21 7 255 18.3 0.1 18.5 18 07/04/2005 09:40:00 1.8 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.4 0.5 2.6 0.4 358 28 28 255 18.7 0 18.8 18.5 07/04/2005 09:50:00 1.2 0.6 2.6 0.4 0.8 0.6 2.3 0.4 1.1 0.5 2.3 0.4 340 36 31 255 18.8 0 19.4 18.5 07/04/2005 10:00:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.9 0.5 2.3 0.4 323 61 340 255 19 0 19.7 18.8 07/04/2005 10:10:00 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 31 26 41 255 19.4 0 20 19.1 07/04/2005 10:20:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.4 0.5 2.6 0.4 27 24 3 255 19.3 0 19.7 19.1 07/04/2005 10:30:00 1.6 0.5 3.4 0.4 1.3 0.6 3.4 0.4 1.5 0.6 3.4 0.4 354 22 7 255 20.1 0.5 21.1 19.4 07/04/2005 10:40:00 1.6 0.7 3.4 0.4 1.3 0.8 3.4 0.4 1.5 0.5 2.6 0.4 357 33 14 255 21.5 0.2 22 20.8 07/04/2005 10:50:00 2 0.7 4.6 0.4 1.8 0.8 3.8 0.4 1.7 0.6 3 0.4 21 35 22 255 21.3 0.2 22.3 21.1 07/04/2005 11:00:00 2.2 0.6 3.8 0.4 1.9 0.7 3.4 0.4 1.7 0.7 4.2 0.4 325 24 275 255 21.3 0 22 21.1 07/04/2005 11:10:00 2.1 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.8 0.7 3.4 0.4 336 29 327 255 21.6 0.3 22.3 21.1 07/04/2005 11:20:00 3.1 1.1 5.7 0.7 2.9 1.2 5.7 0.4 2.6 1.2 5.3 0.4 305 26 302 255 22.2 0.3 22.6 21.4 07/04/2005 11:30:00 2.3 1 4.6 0.4 2.1 1 4.2 0.4 1.9 0.8 4.2 0.4 306 30 321 255 21.7 0.1 22 21.4 07/04/2005 11:40:00 2.9 0.7 4.6 0.7 2.6 0.8 4.6 1.1 2.1 0.7 4.2 0.7 347 22 349 255 21.6 0 21.7 21.1 07/04/2005 11:50:00 2.1 0.5 3.8 0.7 1.8 0.6 3.8 0.4 1.8 0.7 3.4 0.4 346 33 19 255 20.6 0.2 21.1 20.3 07/04/2005 12:00:00 1.5 0.7 3.4 0.4 1.2 0.7 3 0.4 1.2 0.7 3.4 0.4 298 76 357 255 20.8 0 21.1 20.5 07/04/2005 12:10:00 2.4 0.8 4.2 0.4 2.1 1 3.8 0.4 1.9 0.8 3.8 0.4 318 23 314 255 21.3 0 21.4 21.1 07/04/2005 12:20:00 2.4 0.7 4.2 0.7 2.2 0.8 3.8 0.4 2.1 0.7 3.8 0.7 316 20 319 255 21 0 21.1 20.8 07/04/2005 12:30:00 1.8 1 4.6 0.4 1.4 0.9 3.8 0.4 1.4 0.8 3.4 0.4 333 33 307 255 21.3 0.1 22 21.1 07/04/2005 12:40:00 2.2 1.1 4.6 0.4 2 1.2 4.6 0.4 2 1.1 4.6 0.4 294 39 263 255 21.7 0.1 22.3 21.4 07/04/2005 12:50:00 1.6 0.8 4.6 0.4 1.3 0.8 3.8 0.4 1.4 0.6 3 0.4 329 33 326 255 21.9 0.2 22.6 21.7 07/04/2005 13:00:00 1.8 0.9 4.9 0.4 1.5 0.9 4.9 0.4 1.5 0.8 5.3 0.4 41 72 333 255 22.6 0.3 23.2 22 07/04/2005 13:10:00 1.8 1 4.6 0.4 1.5 1 4.6 0.4 1.5 0.8 3.4 0.4 274 76 279 255 22.2 0.3 22.9 22 07/04/2005 13:20:00 2.5 0.9 4.6 0.4 2.4 0.9 4.9 0.4 2.3 0.8 4.2 0.4 293 43 294 255 22.7 0 23.2 22.6 07/04/2005 13:30:00 1.8 1.2 4.9 0.4 1.6 1.2 4.6 0.4 1.5 1 4.6 0.4 255 102 335 255 22.9 0 23.5 22.9 07/04/2005 13:40:00 2.2 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.8 0.8 4.6 0.4 332 33 321 255 22.7 0.1 23.5 22.3 07/04/2005 13:50:00 2.1 0.9 3.8 0.4 1.8 0.8 3.4 0.4 1.6 0.8 3.8 0.4 341 45 329 255 23 0 23.5 22.9 07/04/2005 14:00:00 3 0.8 4.9 1.1 2.8 0.9 4.9 0.4 2.6 0.8 4.6 0.7 311 30 308 255 22.4 0.4 23.2 21.7 07/04/2005 14:10:00 2.2 0.6 4.2 0.4 1.9 0.6 3.8 0.4 1.7 0.7 3.4 0.4 333 23 295 255 22.1 0.3 22.9 21.7 07/04/2005 14:20:00 2 0.9 3.4 0.4 1.8 0.9 3.8 0.4 1.8 0.7 3.4 0.4 317 32 299 255 23.1 0 23.5 22.9 07/04/2005 14:30:00 1.7 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.3 0.7 3 0.4 357 45 335 255 23.1 0.3 23.5 22.6 07/04/2005 14:40:00 2.4 1 5.7 0.4 2.1 1 4.9 0.4 2 1 4.9 0.4 354 32 329 255 23.8 0.1 23.8 23.5 07/04/2005 14:50:00 2.7 0.8 4.6 0.7 2.3 0.9 4.2 0.4 2.2 0.9 4.6 0.4 331 18 339 255 23.3 0.3 23.8 22.9 07/04/2005 15:00:00 1.3 1 4.2 0.4 1.1 0.9 4.2 0.4 1.2 0.8 4.2 0.4 345 30 315 255 23.1 0 23.5 22.6 07/04/2005 15:10:00 2.5 0.6 4.2 1.1 2.2 0.6 4.2 0.7 2.1 0.6 4.6 0.7 347 21 335 255 23.5 0.4 24.4 23.2 07/04/2005 15:20:00 2.6 0.7 4.9 0.7 2.3 0.7 4.6 0.4 2.2 0.8 4.2 0.4 346 35 317 255 24.4 0 25 24.1 07/04/2005 15:30:00 3.2 1.3 6.1 0.4 2.9 1.3 6.1 0.4 2.6 1.3 5.3 0.4 321 33 4 255 24.7 0.1 25 24.4 07/04/2005 15:40:00 4 1 7.2 1.5 3.9 1 6.8 1.5 3.5 1 5.7 1.1 308 17 299 255 23.8 0.5 24.4 22.6 07/04/2005 15:50:00 2.4 0.8 4.6 0.4 2 0.9 4.9 0.4 1.8 0.7 3.8 0.4 324 18 23 255 22.4 0 22.9 22.3 07/04/2005 16:00:00 2.4 0.8 4.6 0.7 2.2 0.8 4.6 0.4 2.1 0.8 4.6 0.4 291 30 298 255 22.7 0.3 23.5 22 07/04/2005 16:10:00 3.2 0.7 4.9 1.5 2.8 0.8 4.9 0.7 2.8 0.9 5.3 0.7 331 16 350 255 23.3 0 23.5 23.2 07/04/2005 16:20:00 2.8 0.9 4.6 0.7 2.6 1 4.2 0.4 2.4 1 4.6 0.4 310 18 309 255 23 0.2 23.5 22.6 07/04/2005 16:30:00 2.4 0.8 4.6 0.4 2.1 0.9 4.6 0.4 2 0.8 4.2 0.4 323 28 295 255 22.3 0 22.6 22.3 07/04/2005 16:40:00 2.4 1 4.6 0.4 2.2 1.2 4.9 0.4 2.2 1.1 4.9 0.4 294 23 285 255 22 0 22.3 21.7 07/04/2005 16:50:00 2.2 0.8 4.9 0.4 2 0.9 4.6 0.4 1.6 0.6 3.4 0.4 307 26 292 255 22.2 0 22.3 22 07/04/2005 17:00:00 2 0.7 3.8 0.4 1.7 0.8 3.8 0.4 1.6 0.7 3.8 0.4 293 43 271 255 22.2 0 22.6 22 07/04/2005 17:10:00 2.8 1 4.9 1.1 2.6 1.1 4.9 0.4 2.3 1 4.9 0.4 297 24 304 255 22.1 0.1 22.6 22 07/04/2005 17:20:00 2.4 0.9 5.3 0.7 2.1 1 5.3 0.4 1.7 0.8 3.8 0.4 295 28 307 255 21.9 0 22 21.4 07/04/2005 17:30:00 2.4 0.8 4.6 0.4 2.1 0.8 4.6 0.4 1.8 0.7 4.2 0.4 287 24 258 255 21.6 0 22 21.4 07/04/2005 17:40:00 2.5 0.6 3.8 1.1 2.3 0.7 3.8 0.4 2.1 0.7 3.4 0.4 294 24 258 255 21.6 0 22.3 21.7 07/04/2005 17:50:00 3.1 0.8 4.9 1.1 3 0.8 4.9 1.1 2.4 1 4.9 0.4 292 19 269 255 21.6 0 21.7 21.4 07/04/2005 18:00:00 3.7 1.1 6.1 0.7 3.6 1.2 6.1 0.4 2.9 1.2 5.7 0.7 310 22 289 255 21.6 0 21.7 21.4 07/04/2005 18:10:00 3 1 5.3 0.7 2.9 1 5.3 0.4 2.5 1.1 4.9 0.4 282 20 266 255 21.3 0 21.7 21.1 07/04/2005 18:20:00 3.6 1.1 6.5 1.5 3.5 1.1 5.7 0.4 3.1 1.2 6.1 0.7 282 22 278 255 20.7 0.2 21.1 20.5 07/04/2005 18:30:00 3.2 1 5.3 0.7 3 1.1 5.7 0.4 2.9 1 5.3 0.4 280 22 313 255 20.5 0 20.5 20.5 07/04/2005 18:40:00 2 1 4.6 0.4 1.8 1 4.2 0.4 1.7 0.8 4.2 0.4 268 32 263 255 20.3 0 20.5 20 07/04/2005 18:50:00 3.7 1.5 7.2 0.4 3.6 1.6 7.2 0.4 2.8 1.3 6.1 0.4 270 28 277 255 19.9 0.3 20.5 19.4 07/04/2005 19:00:00 3.2 1 5.7 0.7 3.1 1 6.1 0.7 2.4 1 5.3 0.4 265 28 289 255 19.4 0 20 19.1 07/04/2005 19:10:00 3.7 1.1 6.8 0.4 3.7 1.2 7.2 1.1 2.8 1 5.7 0.7 261 24 240 255 19.2 0 19.7 19.1 07/04/2005 19:20:00 3.2 1.3 6.8 0.4 3.1 1.4 6.5 0.4 2.7 1.2 5.7 0.4 270 22 280 255 19.1 0.1 19.4 19.1 07/04/2005 19:30:00 3.2 1.3 6.5 0.4 3.1 1.5 6.8 0.4 2.4 1.1 5.3 0.4 253 26 293 255 19 0 19.4 18.8 07/04/2005 19:40:00 3.4 0.9 5.7 1.1 3.3 1 5.7 0.7 2.7 0.9 4.9 0.7 270 18 266 255 18.7 0 19.4 18.5 07/04/2005 19:50:00 2.1 1.2 4.6 0.4 1.9 1.2 4.6 0.4 1.7 1 3.8 0.4 257 27 223 255 18.5 0 18.8 18.2 07/04/2005 20:00:00 3.1 1.2 6.1 0.4 2.9 1.2 6.1 0.4 2.4 1 4.9 0.4 258 19 264 255 18.3 0 18.5 18.2 07/04/2005 20:10:00 2.2 1.1 5.3 0.4 2 1.2 5.3 0.4 1.8 1 4.9 0.4 240 13 233 255 18 0 18.5 18 07/04/2005 20:20:00 1.7 1 3.8 0.4 1.6 1 4.2 0.4 1.3 0.9 3.4 0.4 252 23 253 255 17.8 0 18 17.7 07/04/2005 20:30:00 2.1 0.5 3.4 1.1 1.9 0.6 3 0.4 1.5 0.5 2.6 0.4 252 15 261 255 17.8 0 17.7 17.4 07/04/2005 20:40:00 1.8 0.5 3 0.7 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 277 21 267 255 17.7 0 17.7 17.4 07/04/2005 20:50:00 1.6 0.4 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.5 2.6 0.4 283 17 260 255 17.7 0 17.7 17.4 07/04/2005 21:00:00 1.7 0.6 3 0.4 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 291 17 293 255 17.5 0 17.7 17.4 07/04/2005 21:10:00 1.4 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 302 13 286 255 17.3 0 17.4 17.1 07/04/2005 21:20:00 1.7 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.3 0.5 2.6 0.4 297 14 292 255 17.2 0 17.4 17.1 07/04/2005 21:30:00 1.8 0.5 3 0.7 1.5 0.6 3 0.4 1.2 0.6 2.6 0.4 292 12 291 255 17.1 0 17.4 16.8 07/04/2005 21:40:00 1.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 308 11 319 255 16.8 0 17.1 16.8 07/04/2005 21:50:00 1.2 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 313 5 308 255 16.6 0 16.8 16.6 07/04/2005 22:00:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 307 13 314 255 16.4 0 16.8 16.3 07/04/2005 22:10:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.4 2.3 0.4 310 11 306 255 16.1 0 16.6 16.3 07/04/2005 22:20:00 1 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 314 3 312 255 16.1 0 16.6 16 07/04/2005 22:30:00 1 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 314 8 323 255 15.9 0 16.3 15.7 07/04/2005 22:40:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 286 14 297 255 15.8 0 16.3 15.7 07/04/2005 22:50:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 267 7 262 255 15.7 0 16.3 15.7 07/04/2005 23:00:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 262 7 274 255 15.7 0 16.3 15.7 07/04/2005 23:10:00 1.1 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 264 7 256 255 15.5 0 16 15.5 07/04/2005 23:20:00 1.3 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 282 9 287 255 15.3 0 15.7 15.2 07/04/2005 23:30:00 1.3 0.3 2.3 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 287 12 288 255 15.2 0 15.7 15.2 07/04/2005 23:40:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 286 1 280 255 15 0 15.7 15.2 07/04/2005 23:50:00 1.3 0.3 2.3 0.7 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 294 5 292 255 15.2 0.2 15.7 15.2 07/05/2005 00:00:00 1.1 0.4 2.3 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 291 10 283 255 15.1 0.2 15.7 14.9 07/05/2005 00:10:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 278 6 275 255 15 0 15.7 15.2 07/05/2005 00:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 276 5 275 255 15 0 15.7 14.9 07/05/2005 00:30:00 1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 304 10 295 255 15 0 15.5 14.9 07/05/2005 00:40:00 1.4 0.3 2.3 0.7 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 330 11 303 255 14.9 0 15.5 14.9 07/05/2005 00:50:00 1.5 0.3 2.6 0.7 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 339 10 347 255 14.9 0 15.2 14.9 07/05/2005 01:00:00 1.3 0.3 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 344 10 349 255 14.8 0 15.2 14.6 07/05/2005 01:10:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 344 15 339 255 14.8 0 15.2 14.6 07/05/2005 01:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 324 14 310 255 14.7 0.1 15.2 14.6 07/05/2005 01:30:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 319 5 316 255 14.6 0.1 15.2 14.6 07/05/2005 01:40:00 1 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 352 13 328 255 14.6 0 15.2 14.4 07/05/2005 01:50:00 1.2 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 17 8 18 255 14.3 0.2 14.9 13.8 07/05/2005 02:00:00 1.9 0.4 2.6 0.7 1.6 0.5 2.6 0.4 0.9 0.5 2.3 0.4 5 10 356 255 13.9 0 14.6 13.5 07/05/2005 02:10:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.5 0.4 3 9 352 255 13.5 0 14.1 13.3 07/05/2005 02:20:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.6 0.4 1.5 0.4 358 14 339 255 13.3 0 13.3 13 07/05/2005 02:30:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.9 0.4 353 22 28 255 13.1 0 13.3 13 07/05/2005 02:40:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 17 8 349 255 13 0 13 13 07/05/2005 02:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 4 0 4 255 13 0.1 13.3 13 07/05/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 4 255 13 0.1 13.3 13 07/05/2005 03:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 4 255 13 0.1 13.5 12.7 07/05/2005 03:20:00 0.8 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 4 0 4 255 13 0.1 13.5 12.7 07/05/2005 03:30:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 4 0 4 255 13 0.1 13.5 12.7 07/05/2005 03:40:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 7 4 4 255 13 0.1 13.3 12.7 07/05/2005 03:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 14 0 14 255 13 0.1 13.3 12.7 07/05/2005 04:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 22 14 255 13.1 0.1 13.5 13 07/05/2005 04:10:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 80 0 80 255 13.1 0 13.5 13 07/05/2005 04:20:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 48 12 43 255 13.1 0.1 13.5 13 07/05/2005 04:30:00 0.9 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 22 18 3 255 13.1 0 13.5 13 07/05/2005 04:40:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 23 0 23 255 13.1 0 13.5 13 07/05/2005 04:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 13 15 350 255 13.1 0 13.5 13 07/05/2005 05:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 350 0 350 255 13.1 0 13.5 13 07/05/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 13.3 0 13.8 13 07/05/2005 05:20:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 350 0 350 255 13.4 0 13.8 13.3 07/05/2005 05:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 350 255 13.5 0.1 13.8 13.3 07/05/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 13.6 0 14.1 13.3 07/05/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 13.9 0.1 14.4 13.5 07/05/2005 06:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 350 0 350 255 14.1 0.2 14.6 13.8 07/05/2005 06:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 350 255 14.5 0.2 14.9 14.1 07/05/2005 06:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 350 255 14.7 0.1 15.2 14.6 07/05/2005 06:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 12 10 351 255 14.8 0 15.2 14.6 07/05/2005 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 12 17 255 14.9 0 15.2 14.9 07/05/2005 06:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 54 6 61 255 15 0 15.2 14.9 07/05/2005 07:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 93 35 136 255 15.2 0 15.7 15.2 07/05/2005 07:10:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 146 9 153 255 15.3 0 16 15.5 07/05/2005 07:20:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.5 0.4 146 9 153 255 15.5 0 16 15.5 07/05/2005 07:30:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 164 21 142 255 15.8 0.1 16.3 15.7 07/05/2005 07:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.5 0.4 109 61 125 255 17 0.4 17.7 16.3 07/05/2005 07:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.9 0.4 262 79 189 255 17.8 0.3 18.2 17.4 07/05/2005 08:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 129 35 158 255 18.2 0 18.2 18 07/05/2005 08:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 153 22 128 255 18.3 0.1 18.8 18 07/05/2005 08:20:00 0.6 0.5 3 0.4 0.5 0.4 1.9 0.4 0.6 0.4 2.3 0.4 115 61 43 255 18.2 0.2 18.8 17.7 07/05/2005 08:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 126 76 29 255 18.6 0.1 19.1 18.2 07/05/2005 08:40:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 60 82 334 255 19.1 0.1 19.4 18.8 07/05/2005 08:50:00 1.2 0.7 2.6 0.4 1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 322 49 290 255 18.1 0.4 19.1 17.4 07/05/2005 09:00:00 1.3 0.7 3 0.4 1.1 0.8 3 0.4 1.1 0.6 2.6 0.4 303 79 246 255 19.1 0.3 20 18.2 07/05/2005 09:10:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1.4 0.6 3 0.4 222 22 240 255 18.5 0.4 19.4 17.7 07/05/2005 09:20:00 1.5 0.5 3 0.4 1.3 0.6 2.6 0.4 1.3 0.6 3 0.4 253 17 235 255 17.2 0.2 18 16.8 07/05/2005 09:30:00 0.8 0.5 2.3 0.4 0.6 0.5 1.9 0.4 0.5 0.4 1.9 0.4 277 10 295 255 16.7 0 17.1 16.6 07/05/2005 09:40:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.9 0.6 2.3 0.4 348 64 0 255 18 0.7 19.1 16.8 07/05/2005 09:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.4 2.6 0.4 33 28 39 255 19.6 0.2 20.5 19.1 07/05/2005 10:00:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.7 3 0.4 36 51 289 255 20.1 0.3 21.1 19.7 07/05/2005 10:10:00 1.6 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.4 0.8 3.4 0.4 320 33 280 255 20.2 0.6 21.1 19.1 07/05/2005 10:20:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.9 0.6 2.3 0.4 206 66 209 255 19.3 0.2 20 18.8 07/05/2005 10:30:00 1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.8 0.5 2.6 0.4 235 53 272 255 19.2 0.2 20 18.8 07/05/2005 10:40:00 1.7 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.4 0.8 3.4 0.4 312 33 304 255 18.9 0 19.4 18.5 07/05/2005 10:50:00 1.2 0.6 3 0.4 1 0.6 2.6 0.4 1.2 0.5 3 0.4 37 56 202 255 20.4 0.4 21.1 19.4 07/05/2005 11:00:00 2.2 0.9 4.2 0.4 1.9 1 4.2 0.4 1.8 0.9 4.2 0.4 317 38 247 255 21.2 0.6 22.3 19.7 07/05/2005 11:10:00 1.3 0.8 3 0.4 1 0.7 3.4 0.4 1.3 0.7 3.4 0.4 297 90 307 255 19.3 0.2 20 19.1 07/05/2005 11:20:00 1.7 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1.7 0.6 3.4 0.4 44 21 22 255 20.5 0.2 21.1 20 07/05/2005 11:30:00 1.5 0.8 3.8 0.4 1.3 0.8 3.4 0.4 1.4 0.8 3.4 0.4 314 72 296 255 20.9 0 21.1 20.8 07/05/2005 11:40:00 2.3 1.1 4.9 0.4 2.2 1.1 4.9 0.4 2 1 4.6 0.4 266 33 302 255 21.5 0.3 22 21.1 07/05/2005 11:50:00 3.1 0.8 5.3 0.4 2.9 0.9 4.9 0.4 2.7 0.8 4.9 1.1 305 29 268 255 20.8 0.2 21.7 20.5 07/05/2005 12:00:00 1.4 0.6 3 0.4 1.1 0.6 3 0.4 1.4 0.7 3 0.4 318 79 273 255 21.5 0 22 21.1 07/05/2005 12:10:00 2.3 0.8 4.2 0.4 2.1 0.9 3.8 0.4 2 0.8 3.8 0.4 242 43 248 255 21.3 0 21.7 21.1 07/05/2005 12:20:00 1 0.9 3.8 0.4 0.9 0.9 3.8 0.4 1 0.9 3.4 0.4 67 86 306 255 21.9 0.2 22.3 21.4 07/05/2005 12:30:00 1.5 0.6 3 0.4 1.2 0.7 2.6 0.4 1.1 0.6 2.6 0.4 316 58 351 255 22.3 0.1 22.9 21.7 07/05/2005 12:40:00 2 0.9 4.6 0.4 1.8 1 4.6 0.4 1.7 0.9 3.8 0.4 276 32 252 255 22.7 0 22.9 22.6 07/05/2005 12:50:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 26 43 62 255 22.1 0 22.6 22 07/05/2005 13:00:00 1.6 0.9 4.2 0.4 1.4 0.9 4.6 0.4 1.5 0.8 3.4 0.4 293 66 259 255 21.8 0.2 22.3 21.4 07/05/2005 13:10:00 2.5 1 4.9 0.4 2.2 1 4.9 0.4 2.3 1 4.9 0.4 302 32 300 255 22.6 0.2 22.9 22 07/05/2005 13:20:00 2.8 0.7 4.6 0.7 2.5 0.8 4.2 0.4 2.4 0.9 4.2 0.4 323 22 315 255 23.1 0 23.5 22.9 07/05/2005 13:30:00 2.3 1 4.2 0.4 2.1 1.1 4.2 0.4 2 1 4.6 0.4 285 53 291 255 23 0.3 23.8 22.6 07/05/2005 13:40:00 1.9 0.8 4.2 0.4 1.7 0.9 4.2 0.4 1.6 0.7 3.4 0.4 279 29 278 255 23.5 0.1 23.8 23.2 07/05/2005 13:50:00 1.9 1.1 4.9 0.4 1.6 1.2 4.6 0.4 1.5 1.1 4.9 0.4 307 45 276 255 23.7 0.2 24.1 23.5 07/05/2005 14:00:00 1.4 0.6 3 0.4 1.1 0.7 3.4 0.4 1.3 0.6 3.4 0.4 330 43 330 255 23.8 0 24.1 23.8 07/05/2005 14:10:00 3.3 1.1 6.5 0.7 3 1.2 6.1 0.4 2.5 1.3 5.3 0.4 306 27 311 255 23.4 0.3 23.8 23.2 07/05/2005 14:20:00 1.8 0.9 4.2 0.4 1.6 0.9 4.2 0.4 1.5 0.8 4.6 0.4 283 90 260 255 23.7 0 24.1 23.5 07/05/2005 14:30:00 3.2 1.2 6.1 0.4 2.8 1.1 5.7 0.4 2.8 1 5.7 0.4 324 26 340 255 24 0 24.4 23.8 07/05/2005 14:40:00 2.4 0.9 4.2 0.4 2.1 1 4.2 0.4 1.9 0.9 4.2 0.4 292 61 314 255 24.4 0 24.7 24.1 07/05/2005 14:50:00 2.9 0.9 5.3 0.4 2.6 1 4.9 0.4 2.1 1 4.6 0.4 312 27 339 255 24.8 0 25 24.7 07/05/2005 15:00:00 3 1 5.3 0.4 2.7 1 5.7 0.4 2.3 1 5.3 0.4 301 45 305 255 24.7 0.2 25.3 24.4 07/05/2005 15:10:00 2.4 0.9 4.6 0.4 2.2 1 4.6 0.4 1.9 1 4.9 0.4 303 43 290 255 24.4 0 25 24.1 07/05/2005 15:20:00 2.5 0.8 4.6 0.4 2.3 1 4.6 0.4 2 1 4.6 0.4 306 32 271 255 24.6 0 25 24.4 07/05/2005 15:30:00 3.3 1 6.1 1.1 3.1 1.1 6.1 0.4 3 1 5.7 0.4 298 22 298 255 24.1 0.1 24.4 23.8 07/05/2005 15:40:00 3.5 0.8 6.1 1.1 3.4 0.9 6.1 1.1 3.2 0.9 6.1 1.1 304 14 308 255 23.9 0 24.1 23.8 07/05/2005 15:50:00 2.8 0.8 4.9 0.7 2.5 0.8 4.9 0.4 2.3 0.8 4.2 0.4 314 33 300 255 24.3 0 24.7 24.1 07/05/2005 16:00:00 3.3 1 5.7 1.5 3.1 1 5.3 1.1 2.7 0.9 5.3 0.7 306 19 295 255 24.7 0 25 24.4 07/05/2005 16:10:00 2.8 0.8 5.3 1.1 2.5 0.9 4.9 0.4 2.2 1 4.2 0.4 324 28 297 255 24.6 0 25 24.4 07/05/2005 16:20:00 2.4 1 5.3 0.4 2.2 1 5.3 0.4 1.9 0.9 4.9 0.4 314 39 257 255 24.4 0 25 24.1 07/05/2005 16:30:00 3.4 0.9 5.3 1.1 3.2 1 5.7 0.7 3 0.9 5.3 1.1 304 24 294 255 24.1 0.2 24.7 23.8 07/05/2005 16:40:00 3.8 1.1 6.8 0.7 3.4 1.2 6.5 0.4 3.1 1.2 5.7 0.4 319 22 262 255 23.9 0 24.4 23.8 07/05/2005 16:50:00 3.9 1.1 6.5 1.5 3.7 1.2 6.1 0.7 3.2 1.2 6.1 0.4 306 16 313 255 23.8 0 23.8 23.8 07/05/2005 17:00:00 3 1.2 6.8 0.7 2.8 1.2 6.5 0.4 2.5 1.1 5.3 0.4 298 22 301 255 23.8 0 23.8 23.8 07/05/2005 17:10:00 2.9 1 4.9 0.4 2.8 1 4.9 0.4 2.5 0.9 4.2 0.4 287 26 266 255 23.7 0 23.8 23.5 07/05/2005 17:20:00 2.5 1.3 6.8 0.4 2.2 1.4 6.8 0.4 1.8 1.1 6.1 0.4 308 28 310 255 24.2 0 24.4 23.8 07/05/2005 17:30:00 3 1 5.3 0.7 2.8 1.1 5.7 0.4 2.4 1.1 5.3 0.4 309 27 256 255 24.1 0 24.4 24.1 07/05/2005 17:40:00 4.1 1 6.5 1.5 3.9 1.1 6.5 1.1 3.4 1 6.1 1.5 319 21 316 255 24.1 0 24.4 24.1 07/05/2005 17:50:00 4 1.2 7.2 0.7 3.8 1.2 7.2 1.1 3.3 1.2 6.1 0.7 316 21 293 255 23.9 0 24.1 23.8 07/05/2005 18:00:00 3.6 1 6.8 1.5 3.3 1 6.1 1.1 2.6 1.1 5.7 0.4 312 27 269 255 23.9 0 24.1 23.8 07/05/2005 18:10:00 3.6 0.9 6.1 1.9 3.3 1 6.1 0.4 2.9 1 5.3 0.7 313 21 329 255 24.1 0 24.4 23.8 07/05/2005 18:20:00 3.9 1 6.8 1.5 3.7 1.1 6.5 1.1 3.1 1 6.5 0.7 310 14 291 255 23.6 0 23.8 23.5 07/05/2005 18:30:00 3.2 0.9 6.1 1.5 3 1 5.7 1.1 2.7 1 5.3 0.7 321 18 296 255 23.5 0 23.5 23.5 07/05/2005 18:40:00 3.3 0.9 5.7 1.1 2.9 0.9 5.3 0.7 2.3 0.9 5.3 0.7 339 16 343 255 23.2 0.1 23.5 22.9 07/05/2005 18:50:00 1.6 1.1 3.8 0.4 1.3 1 3.8 0.4 1.3 0.9 3.8 0.4 317 32 338 255 22.4 0 22.9 22.3 07/05/2005 19:00:00 2.6 0.9 4.9 0.7 2.5 0.9 4.9 0.4 2.2 0.8 4.6 0.4 94 17 88 255 21.6 0.3 22.3 20.8 07/05/2005 19:10:00 4.2 0.7 5.7 2.3 4.1 0.7 5.7 2.3 3.6 0.8 5.3 1.5 91 13 86 255 20.5 0.2 21.1 20 07/05/2005 19:20:00 2.7 1.1 5.7 0.7 2.5 1.2 5.3 0.4 2.3 1 5.3 0.4 80 23 74 255 19.7 0.2 20.3 19.4 07/05/2005 19:30:00 1.7 0.6 3.4 0.4 1.4 0.6 3.4 0.4 1.4 0.6 3.4 0.4 63 17 54 255 19.5 0 19.7 19.1 07/05/2005 19:40:00 1 0.7 3 0.4 0.9 0.7 3 0.4 0.9 0.6 2.6 0.4 93 36 73 255 19.2 0 19.7 19.1 07/05/2005 19:50:00 1.5 0.8 3.4 0.4 1.3 0.8 3 0.4 1.3 0.6 2.6 0.4 135 28 131 255 18.9 0 19.4 18.5 07/05/2005 20:00:00 2.6 0.9 4.6 0.7 2.4 1 4.6 0.4 2.3 0.9 4.2 0.7 122 14 121 255 18.6 0.1 19.1 18.2 07/05/2005 20:10:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.7 112 16 127 255 18.2 0 18.8 18 07/05/2005 20:20:00 2.1 0.6 3.4 0.7 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 103 14 108 255 17.9 0 18 17.7 07/05/2005 20:30:00 1.6 0.5 3 0.4 1.3 0.6 2.6 0.4 1.3 0.5 2.3 0.4 129 10 145 255 17.8 0 18 17.7 07/05/2005 20:40:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.3 1.9 0.4 100 22 113 255 17.7 0 17.7 17.4 07/05/2005 20:50:00 1.5 0.3 2.3 0.7 1.2 0.3 2.3 0.7 0.9 0.3 1.9 0.4 75 9 73 255 17 0.1 17.4 16.6 07/05/2005 21:00:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 69 8 68 255 16.3 0.2 16.8 16 07/05/2005 21:10:00 1.8 0.5 3.4 0.7 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 49 18 34 255 15.8 0 16 15.7 07/05/2005 21:20:00 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 1.3 0.3 2.3 0.7 53 10 51 255 15.5 0 15.7 15.2 07/05/2005 21:30:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 0.7 1.7 0.4 2.6 0.7 62 8 67 255 15.2 0.1 15.7 15.2 07/05/2005 21:40:00 2.1 0.6 3.4 0.7 1.9 0.7 3.4 0.4 1.5 0.4 2.6 0.4 67 12 64 255 15.1 0.1 15.7 14.9 07/05/2005 21:50:00 2.3 0.3 3 1.5 2 0.3 2.6 1.1 1.2 0.4 2.6 0.4 89 6 94 255 14.7 0 15.5 14.6 07/05/2005 22:00:00 1.9 0.4 3.4 1.1 1.6 0.4 3 0.7 1 0.5 2.6 0.4 97 10 92 255 14.2 0.1 14.9 13.8 07/05/2005 22:10:00 2.4 0.3 3 1.5 2.2 0.4 3 0.7 1.7 0.4 2.6 0.7 98 8 100 255 14.1 0.1 14.6 13.8 07/05/2005 22:20:00 2 0.4 3 1.1 1.8 0.4 3.4 0.7 1.2 0.4 2.3 0.4 93 8 87 255 13.9 0 14.6 13.8 07/05/2005 22:30:00 1.8 0.4 2.6 0.7 1.5 0.4 2.3 0.4 1 0.4 1.9 0.4 101 9 93 255 13.7 0 14.4 13.3 07/05/2005 22:40:00 1.6 0.3 2.3 0.7 1.3 0.3 2.3 0.4 1.1 0.4 2.3 0.4 119 14 98 255 13.5 0 13.8 13.3 07/05/2005 22:50:00 2.2 0.5 3 0.7 1.9 0.5 3 0.4 1.5 0.5 2.6 0.4 122 11 138 255 13.3 0 13.8 13 07/05/2005 23:00:00 1.8 0.5 3 0.7 1.5 0.6 3 0.4 1 0.4 1.9 0.4 116 9 113 255 13.2 0.2 13.5 13 07/05/2005 23:10:00 2.4 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1.5 0.4 2.6 0.4 113 12 113 255 13.3 0 13.5 13 07/05/2005 23:20:00 2.7 0.6 4.2 1.1 2.4 0.6 3.8 1.1 1.6 0.5 3 0.4 115 14 115 255 13.2 0 13.5 13 07/05/2005 23:30:00 3 0.5 4.2 1.5 2.9 0.5 3.8 1.5 2 0.5 3.4 0.7 112 12 102 255 13.1 0.1 13.3 12.7 07/05/2005 23:40:00 3.1 0.5 4.6 1.1 2.9 0.6 4.2 1.1 2 0.6 3.8 0.7 112 13 105 255 13 0 13.5 12.7 07/05/2005 23:50:00 2.7 0.6 4.6 1.5 2.5 0.6 4.2 1.1 1.7 0.5 3 0.7 114 14 112 255 12.9 0 13.3 12.7 07/06/2005 00:00:00 3.1 0.4 3.8 1.9 2.9 0.5 3.8 1.5 1.9 0.5 3.4 0.7 109 12 102 255 13 0.1 13.3 12.7 07/06/2005 00:10:00 2.3 0.6 4.2 0.7 2.1 0.7 3.8 0.4 1.2 0.7 3.4 0.4 91 21 98 255 12.9 0 13.3 12.7 07/06/2005 00:20:00 2.7 0.6 4.2 1.1 2.5 0.6 3.8 0.4 1.5 0.6 3 0.4 102 12 113 255 12.5 0.1 13 12.2 07/06/2005 00:30:00 2.2 0.5 3.8 1.1 2 0.5 3.4 0.7 1.6 0.4 2.6 0.7 119 11 117 255 12.1 0 12.7 11.9 07/06/2005 00:40:00 2.2 0.6 3.8 1.1 2 0.7 3.4 0.4 1.3 0.6 3 0.4 112 9 119 255 11.9 0.1 12.2 11.7 07/06/2005 00:50:00 1.8 0.5 3 0.4 1.5 0.6 2.6 0.4 1.1 0.4 2.3 0.4 118 11 108 255 11.7 0 12.2 11.7 07/06/2005 01:00:00 2.1 0.6 3.4 0.7 1.8 0.6 3.4 0.4 1.3 0.4 2.3 0.4 118 9 101 255 11.5 0 12.2 11.4 07/06/2005 01:10:00 2.1 0.5 3.4 0.7 1.9 0.5 3 0.4 1.6 0.5 3 0.4 122 9 132 255 11.3 0 11.7 11.1 07/06/2005 01:20:00 2.5 0.5 3.8 1.1 2.3 0.6 3.8 0.7 1.7 0.5 3 0.4 118 9 116 255 11.5 0.1 11.9 11.1 07/06/2005 01:30:00 2.7 0.4 3.8 1.5 2.4 0.5 3.4 1.1 1.7 0.5 3.4 0.4 111 9 107 255 11.5 0 11.9 11.4 07/06/2005 01:40:00 2.5 0.5 3.8 1.1 2.3 0.5 3.4 0.7 1.6 0.5 3 0.4 113 10 108 255 11.4 0.1 11.9 11.4 07/06/2005 01:50:00 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.1 1.6 0.6 3 0.4 108 11 113 255 11.3 0 11.7 11.1 07/06/2005 02:00:00 2.3 0.6 3.8 0.7 2.1 0.6 3.4 0.4 1.4 0.5 2.6 0.4 112 12 119 255 11.2 0 11.7 11.1 07/06/2005 02:10:00 2.5 0.6 3.8 1.1 2.3 0.6 3.8 0.7 1.5 0.6 3 0.4 114 13 118 255 11.1 0 11.4 11.1 07/06/2005 02:20:00 3.1 0.4 4.2 1.9 2.9 0.5 3.8 1.9 2 0.6 3.4 0.7 111 10 113 255 11.1 0 11.4 11.1 07/06/2005 02:30:00 3 0.5 3.8 1.1 2.8 0.6 3.8 0.7 2 0.6 3.4 0.7 110 10 103 255 11.3 0 11.4 11.1 07/06/2005 02:40:00 2.4 0.5 3.8 1.1 2.1 0.5 3.4 1.1 1.5 0.5 2.6 0.4 113 10 121 255 11.1 0 11.1 10.9 07/06/2005 02:50:00 2.6 0.4 3.4 1.5 2.4 0.5 3.4 0.7 1.7 0.5 3.4 0.7 115 10 109 255 10.7 0 10.9 10.6 07/06/2005 03:00:00 2.8 0.5 4.2 1.1 2.5 0.6 3.8 0.7 1.6 0.4 2.6 0.7 111 10 113 255 10.5 0 10.6 10.6 07/06/2005 03:10:00 2.5 0.5 3.8 0.7 2.2 0.5 3.4 0.7 1.6 0.5 3 0.4 115 10 113 255 10.6 0 10.6 10.6 07/06/2005 03:20:00 2.4 0.6 4.2 0.7 2.2 0.7 3.8 0.4 1.4 0.6 3.4 0.4 119 13 97 255 10.6 0 10.6 10.6 07/06/2005 03:30:00 2.6 0.6 4.2 1.1 2.4 0.7 3.8 0.4 1.5 0.5 3 0.4 113 13 100 255 10.7 0.1 10.9 10.6 07/06/2005 03:40:00 2.5 0.5 3.8 1.5 2.2 0.5 3.8 0.7 1.4 0.6 3 0.4 115 13 102 255 11 0 11.1 10.9 07/06/2005 03:50:00 2.8 0.6 4.2 1.1 2.7 0.7 4.2 0.7 1.7 0.6 3.4 0.4 111 14 127 255 11.1 0 11.7 11.1 07/06/2005 04:00:00 2.8 0.7 4.2 0.7 2.5 0.8 4.2 0.4 1.8 0.8 3.4 0.4 106 14 112 255 11.1 0 11.4 11.1 07/06/2005 04:10:00 2.8 0.6 4.2 1.1 2.6 0.6 3.8 0.7 1.8 0.6 3 0.4 107 10 102 255 11.5 0 11.7 11.4 07/06/2005 04:20:00 3.2 0.4 4.2 1.9 3 0.4 4.2 1.9 2.1 0.5 3.4 0.7 105 10 105 255 11.4 0 11.7 11.4 07/06/2005 04:30:00 3 0.5 4.2 1.5 2.7 0.6 4.2 1.1 1.9 0.6 3.4 0.4 108 11 95 255 11.6 0 12.2 11.4 07/06/2005 04:40:00 2.6 0.7 4.2 1.1 2.3 0.7 4.2 0.7 1.5 0.6 3.4 0.4 112 16 108 255 11.9 0 12.2 11.7 07/06/2005 04:50:00 2.8 0.6 4.6 1.5 2.7 0.7 4.2 1.5 2 0.6 3.8 0.7 110 12 102 255 12.1 0 12.5 11.9 07/06/2005 05:00:00 2.6 0.7 4.6 0.7 2.4 0.8 4.6 0.4 1.9 0.7 3.8 0.4 113 18 112 255 12.7 0.1 13.3 12.5 07/06/2005 05:10:00 2.8 0.6 4.6 1.5 2.6 0.7 4.2 0.7 2.1 0.7 3.4 0.4 112 17 112 255 13 0.1 13.5 12.7 07/06/2005 05:20:00 2.7 0.9 4.9 0.7 2.4 1 4.9 0.4 1.7 1 3.8 0.4 110 19 105 255 13.3 0 13.8 13.3 07/06/2005 05:30:00 1.6 0.6 3.4 0.4 1.3 0.7 3 0.4 1.1 0.5 2.6 0.4 116 22 154 255 13.7 0.2 13.8 13.3 07/06/2005 05:40:00 1.8 0.5 3 0.7 1.5 0.6 3 0.4 1.5 0.5 3.4 0.4 111 17 105 255 13.9 0 14.4 13.8 07/06/2005 05:50:00 2.3 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.8 0.7 3 0.4 101 13 105 255 14.6 0 14.9 14.4 07/06/2005 06:00:00 2.3 0.5 3.4 1.1 2.1 0.5 3.4 1.1 1.9 0.5 3 0.4 104 11 110 255 15.2 0 15.7 14.9 07/06/2005 06:10:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 2.2 0.6 3.4 0.7 104 9 101 255 15.8 0 16.3 15.7 07/06/2005 06:20:00 2.2 0.5 3.4 1.1 2 0.5 3 0.4 1.8 0.6 2.6 0.4 106 12 94 255 16.1 0.1 16.6 15.7 07/06/2005 06:30:00 2 0.5 3 0.7 1.6 0.6 3 0.4 1.6 0.7 3 0.4 109 14 101 255 16.1 0 16.6 16 07/06/2005 06:40:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 1.6 0.4 2.6 0.7 107 13 104 255 16.4 0.2 17.1 16 07/06/2005 06:50:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1.6 0.4 2.3 0.4 85 17 77 255 17.3 0.1 17.7 16.8 07/06/2005 07:00:00 1.9 0.5 3 0.4 1.7 0.6 3 0.4 1.6 0.6 3 0.4 73 22 90 255 18 0.1 18.2 17.4 07/06/2005 07:10:00 1.9 0.4 3 0.7 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 56 27 86 255 18.5 0.2 19.4 18 07/06/2005 07:20:00 2 0.5 3.4 0.7 1.8 0.5 3 0.4 1.8 0.5 2.6 0.4 37 13 74 255 19.1 0 19.4 18.8 07/06/2005 07:30:00 1.6 0.5 3 0.4 1.3 0.6 3 0.4 1.3 0.5 2.6 0.4 48 29 36 255 18.5 0.2 19.1 18 07/06/2005 07:40:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 2.1 0.6 3.8 0.4 46 20 58 255 18.2 0.1 18.8 18 07/06/2005 07:50:00 2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 1.7 0.5 3 0.7 24 13 24 255 19 0 19.4 18.5 07/06/2005 08:00:00 2 0.5 3.4 0.4 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 43 13 35 255 19 0.2 19.7 18.5 07/06/2005 08:10:00 2 0.6 3.8 0.7 1.8 0.6 3.8 0.4 1.6 0.7 3.4 0.4 63 16 62 255 18.7 0.1 19.1 18.5 07/06/2005 08:20:00 2.7 0.4 3.8 1.5 2.6 0.5 3.8 0.7 2.3 0.6 3.4 0.4 35 20 22 255 19.2 0.2 20.3 18.5 07/06/2005 08:30:00 2.3 0.7 3.8 0.7 2.2 0.8 3.4 0.4 2.2 0.7 3.4 0.4 14 13 40 255 20 0 20.5 19.7 07/06/2005 08:40:00 1.6 0.5 3 0.7 1.3 0.6 2.6 0.4 1.3 0.4 2.3 0.4 8 15 17 255 19.6 0.2 20.3 19.1 07/06/2005 08:50:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 13 15 1 255 19 0 19.4 18.8 07/06/2005 09:00:00 1.3 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.5 1.9 0.4 27 27 26 255 19 0 19.4 18.8 07/06/2005 09:10:00 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.5 2.6 0.4 1 17 348 255 19.4 0.1 20 19.1 07/06/2005 09:20:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 57 53 47 255 19.7 0.1 20.5 19.4 07/06/2005 09:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 29 30 49 255 19.7 0 20 19.4 07/06/2005 09:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 333 39 297 255 19.9 0 20.3 19.7 07/06/2005 09:50:00 1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.9 0.6 2.3 0.4 57 23 64 255 20.3 0.3 20.8 20 07/06/2005 10:00:00 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.2 0.5 2.3 0.4 56 35 58 255 21.2 0.1 21.4 20.8 07/06/2005 10:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 9 27 56 255 21.3 0 21.7 21.1 07/06/2005 10:20:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 297 41 341 255 21.6 0 22 21.4 07/06/2005 10:30:00 1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.9 0.4 1.9 0.4 311 82 16 255 22.1 0 22.6 22 07/06/2005 10:40:00 1.5 0.7 3 0.4 1.3 0.7 3 0.4 1.3 0.6 2.6 0.4 23 39 12 255 22.2 0 22.9 22.3 07/06/2005 10:50:00 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.5 2.3 0.4 56 39 30 255 22.8 0.2 23.5 22.3 07/06/2005 11:00:00 1.5 0.4 2.6 0.4 1.3 0.5 2.3 0.4 1.4 0.4 2.3 0.4 71 28 48 255 23.3 0.2 23.8 22.9 07/06/2005 11:10:00 1.3 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.5 2.6 0.4 84 58 39 255 23.4 0.1 23.8 23.2 07/06/2005 11:20:00 1.8 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1.4 0.7 3.4 0.4 317 39 308 255 23.9 0 24.4 23.8 07/06/2005 11:30:00 2.1 0.8 4.2 0.4 1.9 0.8 3.8 0.4 1.6 0.6 3.8 0.4 17 58 351 255 24.2 0.2 24.7 23.8 07/06/2005 11:40:00 2.8 0.8 4.9 1.1 2.6 0.8 5.3 0.7 2.3 0.8 4.9 0.7 292 33 307 255 24.5 0.2 25 24.1 07/06/2005 11:50:00 2 0.9 4.2 0.4 1.8 1 4.6 0.4 1.6 0.8 4.6 0.4 297 39 335 255 24.4 0 25 24.1 07/06/2005 12:00:00 2.1 0.8 4.2 0.4 1.9 0.9 3.8 0.4 1.8 0.9 4.2 0.4 313 33 315 255 24.4 0.2 25 23.8 07/06/2005 12:10:00 1.9 0.7 3.4 0.4 1.7 0.7 3 0.4 1.7 0.8 3.4 0.4 263 43 283 255 24.1 0.2 24.7 23.5 07/06/2005 12:20:00 2 1.2 4.6 0.4 1.8 1.2 4.6 0.4 1.6 1 4.2 0.4 290 51 340 255 24.4 0.4 25 23.8 07/06/2005 12:30:00 2.3 1 4.6 0.4 2.1 1 4.2 0.4 2.3 1 4.2 0.4 274 36 291 255 24.4 0.4 25 23.8 07/06/2005 12:40:00 2.4 1.3 5.3 0.4 2.2 1.4 4.9 0.4 2.1 1.3 5.3 0.4 300 41 301 255 24.1 0.1 24.7 23.8 07/06/2005 12:50:00 2.4 1 5.7 0.7 2 0.9 4.9 0.4 2 0.8 4.9 0.4 326 32 335 255 25.3 0.3 25.6 24.7 07/06/2005 13:00:00 2.8 1.1 4.9 0.7 2.6 1.2 4.9 0.4 2.4 1.1 4.2 0.4 316 17 321 255 25.5 0 25.6 25.3 07/06/2005 13:10:00 2.2 1 4.6 0.4 1.9 1 4.6 0.4 2 0.9 4.6 0.4 334 49 310 255 25.3 0 25.6 25 07/06/2005 13:20:00 2.8 0.8 4.9 1.1 2.6 1 5.3 0.4 2.4 0.8 4.6 0.4 291 26 282 255 25.2 0 25.6 25 07/06/2005 13:30:00 2.7 1 4.9 0.7 2.3 0.9 4.6 0.4 2.2 0.9 4.6 0.4 342 24 327 255 25.9 0.1 26.5 25.6 07/06/2005 13:40:00 2.9 1 4.9 0.4 2.6 1 4.9 0.4 2.2 0.9 4.2 0.4 332 32 23 255 26.5 0 26.8 26.5 07/06/2005 13:50:00 2.5 1 4.9 0.4 2.2 1.1 4.9 0.4 2.1 1 4.2 0.4 299 58 334 255 26.2 0.2 26.8 26.2 07/06/2005 14:00:00 3.1 0.8 5.7 1.1 2.8 1 5.3 0.7 2.7 1 4.6 0.4 305 29 270 255 26.4 0.3 27.1 25.6 07/06/2005 14:10:00 2.5 1 4.6 0.4 2.2 1 4.2 0.4 2 0.9 4.6 0.4 329 30 323 255 26.3 0.3 27.1 25.6 07/06/2005 14:20:00 3 1 5.3 0.4 2.7 1 5.3 0.4 2.5 0.9 5.7 0.4 347 27 325 255 27 0.1 27.1 26.5 07/06/2005 14:30:00 2.8 0.8 4.6 0.4 2.4 0.7 4.6 0.4 2.1 0.7 4.2 0.7 323 33 337 255 26.4 0 26.8 26.2 07/06/2005 14:40:00 1.9 0.8 3.8 0.4 1.6 0.9 3.8 0.4 1.4 0.8 3.4 0.4 334 30 350 255 26.2 0.2 26.5 25.6 07/06/2005 14:50:00 1.7 0.7 3.8 0.4 1.2 0.7 3 0.4 1.2 0.8 3 0.4 342 24 344 255 25.1 0.2 25.6 25 07/06/2005 15:00:00 1.5 0.7 3.8 0.4 1.1 0.8 3.8 0.4 1 0.7 3 0.4 357 32 358 255 24.4 0.1 25 24.1 07/06/2005 15:10:00 3.2 0.8 5.3 1.1 3.1 1 4.9 0.4 2.4 1.1 5.3 0.4 10 22 34 255 24 0.1 24.4 23.5 07/06/2005 15:20:00 3.1 0.8 5.3 1.5 3 0.8 5.3 1.1 2.6 0.8 4.6 0.4 80 32 100 255 23.3 0.1 23.8 22.9 07/06/2005 15:30:00 3.6 1 6.5 1.5 3.5 1 6.1 1.9 3.2 1 6.1 0.7 120 19 121 255 22.2 0.3 22.9 21.7 07/06/2005 15:40:00 3.4 1.1 6.1 1.1 3.3 1.1 5.7 0.7 2.9 1 5.3 0.7 131 19 136 255 21.5 0 22 21.1 07/06/2005 15:50:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.5 2.6 0.6 4.2 1.1 148 13 124 255 21.2 0 21.7 21.1 07/06/2005 16:00:00 4.3 0.8 6.1 2.6 4.3 0.8 6.1 2.3 3.4 0.6 5.7 1.9 135 12 124 255 19.5 0.9 21.1 18.2 07/06/2005 16:10:00 3.9 0.8 6.1 2.3 3.8 0.8 5.7 2.3 3.1 0.8 5.3 1.5 142 17 142 255 17.8 0.2 18.2 17.4 07/06/2005 16:20:00 4 0.7 5.7 1.9 3.9 0.7 5.7 2.3 2.9 0.7 4.6 0.7 134 12 142 255 17.7 0 18.2 17.4 07/06/2005 16:30:00 3.2 0.6 4.2 1.5 3.1 0.6 4.2 1.1 2.1 0.5 3.4 0.7 118 9 115 255 18 0 18.5 17.7 07/06/2005 16:40:00 2 1 4.2 0.4 1.8 1 3.8 0.4 1.1 0.5 2.3 0.4 107 23 117 255 18.2 0 18.5 18 07/06/2005 16:50:00 1.9 1 3.8 0.4 1.7 1 3.8 0.4 1.6 0.9 3.8 0.4 70 41 51 255 18.3 0 18.8 18.2 07/06/2005 17:00:00 1.8 0.9 4.2 0.4 1.5 0.9 3.4 0.4 1.2 0.7 3.4 0.4 96 15 91 255 18.7 0 19.4 18.5 07/06/2005 17:10:00 0.9 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.3 1.5 0.4 86 15 102 255 19 0.1 19.7 18.8 07/06/2005 17:20:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 92 9 92 255 19.2 0 19.7 19.1 07/06/2005 17:30:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 84 20 93 255 19.6 0.1 20.3 19.4 07/06/2005 17:40:00 2 0.7 3.4 0.4 1.8 0.7 3 0.4 1.6 0.6 3 0.4 92 22 129 255 19.7 0 20.3 19.7 07/06/2005 17:50:00 3 1 5.7 0.7 2.8 1.1 6.1 0.4 2.4 1 4.9 0.4 106 22 113 255 19.9 0.1 20.5 19.7 07/06/2005 18:00:00 4.2 1.1 8 1.9 4.1 1.1 8 1.9 3.6 1.1 6.8 1.5 112 23 110 255 19.8 0.2 20.5 19.4 07/06/2005 18:10:00 3.4 0.9 5.7 1.5 3.3 1 5.7 1.1 2.7 0.8 4.9 0.7 115 19 146 255 18.8 0.2 19.7 18.2 07/06/2005 18:20:00 3.4 0.9 6.1 1.5 3.3 1 6.1 1.1 2.8 0.8 5.3 1.1 108 21 87 255 18 0.1 18.8 17.7 07/06/2005 18:30:00 3.3 0.8 5.3 1.1 3.1 0.9 5.7 0.7 2.7 0.9 4.6 0.7 95 17 81 255 17.6 0 18.2 17.4 07/06/2005 18:40:00 2.6 0.7 4.6 0.7 2.3 0.8 4.2 0.4 2 0.8 4.2 0.4 102 23 107 255 17.3 0 17.7 17.1 07/06/2005 18:50:00 3.2 1 6.1 1.5 3.3 1.1 5.7 1.1 2.6 0.8 5.3 1.1 164 35 204 255 16.8 0.2 17.1 16.3 07/06/2005 19:00:00 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.5 2.6 0.4 175 38 97 255 15.7 0.3 16.3 15.2 07/06/2005 19:10:00 2.2 0.6 4.2 0.7 2 0.7 4.2 0.4 1.7 0.5 3 0.7 89 16 90 255 15.2 0 15.5 15.2 07/06/2005 19:20:00 3.5 0.5 4.9 2.3 3.4 0.5 4.9 1.9 2.6 0.5 3.8 1.1 89 9 96 255 15 0 15.7 15.2 07/06/2005 19:30:00 4.2 0.7 5.7 2.3 4.1 0.7 5.7 1.9 3.3 0.7 4.9 1.1 109 11 121 255 15.2 0.1 15.7 15.2 07/06/2005 19:40:00 3.2 1 5.7 1.5 3 1 5.7 1.1 2.4 1 4.9 0.4 105 14 88 255 15.2 0 15.7 15.2 07/06/2005 19:50:00 1.9 0.4 3 0.7 1.6 0.5 2.6 0.4 0.8 0.4 2.3 0.4 103 12 88 255 15.2 0 15.7 15.2 07/06/2005 20:00:00 1.4 0.6 2.6 0.4 1 0.7 2.6 0.4 0.7 0.5 1.9 0.4 101 26 113 255 15.5 0 16 15.2 07/06/2005 20:10:00 1.6 0.4 2.6 0.4 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 91 18 113 255 15.7 0 16.3 15.7 07/06/2005 20:20:00 2.1 0.4 3 1.1 1.7 0.5 3.4 0.4 1.5 0.4 2.3 0.4 101 12 90 255 15.9 0 16.3 15.7 07/06/2005 20:30:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.5 2.3 0.6 4.2 0.7 123 12 147 255 16.1 0 16.6 16 07/06/2005 20:40:00 2.9 0.6 4.6 1.1 2.7 0.7 4.2 0.7 2 0.6 3.4 0.4 113 11 99 255 16.1 0 16.8 16 07/06/2005 20:50:00 3.3 0.5 4.6 1.1 3.2 0.5 4.2 1.5 2 0.6 3.8 0.4 108 10 104 255 16 0 16.3 15.7 07/06/2005 21:00:00 3.8 0.6 5.3 2.3 3.7 0.6 4.9 1.9 2.7 0.6 4.6 0.7 116 10 105 255 15.9 0 16.3 15.7 07/06/2005 21:10:00 3.9 0.5 5.3 2.3 3.7 0.5 4.9 2.3 2.9 0.5 4.2 1.9 133 11 122 255 15.8 0 16.3 15.7 07/06/2005 21:20:00 3.9 0.5 4.9 2.6 3.7 0.5 4.9 2.3 2.9 0.5 4.2 1.5 136 8 127 255 15.7 0 16.3 15.7 07/06/2005 21:30:00 3.2 0.6 4.9 1.5 3 0.6 4.9 1.5 2.2 0.6 4.2 0.7 98 19 140 255 15.7 0 16 15.5 07/06/2005 21:40:00 3 0.5 4.2 1.5 2.8 0.6 4.6 1.1 2 0.6 3.4 0.4 79 9 86 255 15.5 0.1 16 15.2 07/06/2005 21:50:00 3 0.5 4.2 1.9 2.8 0.6 4.2 1.5 2.2 0.5 3.4 0.7 92 11 108 255 15.3 0.1 15.7 15.2 07/06/2005 22:00:00 4.3 0.6 6.5 2.3 4.2 0.6 6.1 2.3 3.3 0.6 6.1 1.9 57 17 13 255 15.6 0.2 16.3 15.2 07/06/2005 22:10:00 3.9 0.5 5.3 2.6 3.7 0.6 5.3 2.3 3 0.6 4.6 1.5 39 14 31 255 15.9 0 16.3 15.7 07/06/2005 22:20:00 2.9 0.8 4.9 1.5 2.7 0.9 4.9 0.7 1.9 0.8 4.2 0.4 18 23 9 255 15.8 0 16.3 15.5 07/06/2005 22:30:00 1.7 0.9 4.9 0.4 1.3 1 4.9 0.4 1.3 0.9 3.8 0.4 81 58 88 255 15.3 0.2 16 15.2 07/06/2005 22:40:00 3.9 0.8 5.7 1.9 3.7 0.9 5.7 1.5 2.9 0.8 4.9 1.5 50 17 55 255 15.4 0.1 15.7 15.2 07/06/2005 22:50:00 2.5 0.5 3.8 1.1 2.2 0.5 3.4 0.4 1.8 0.5 3.4 0.4 72 21 67 255 15.3 0.2 16 14.9 07/06/2005 23:00:00 2.2 0.7 4.2 0.7 1.9 0.8 4.6 0.4 1.5 0.7 4.6 0.4 77 22 94 255 15 0 15.5 14.6 07/06/2005 23:10:00 2.6 0.6 4.2 1.1 2.3 0.7 4.2 0.7 1.9 0.6 3 0.4 90 26 80 255 14.7 0 15.2 14.6 07/06/2005 23:20:00 2.3 0.5 3.8 0.7 1.9 0.6 3.4 0.4 1.4 0.6 3 0.4 87 17 91 255 14.6 0 15.2 14.6 07/06/2005 23:30:00 2.6 0.6 3.8 1.1 2.3 0.7 3.8 0.4 1.8 0.6 3.4 0.4 82 18 69 255 14.5 0 14.9 14.4 07/06/2005 23:40:00 2.4 0.5 4.2 1.1 2.1 0.6 3.8 0.7 1.5 0.6 3 0.4 86 13 84 255 14.6 0 15.2 14.4 07/06/2005 23:50:00 2.9 0.8 4.2 0.4 2.6 0.8 4.6 0.4 1.8 0.8 3.4 0.4 89 13 81 255 14.4 0.2 14.9 14.1 07/07/2005 00:00:00 3.3 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.3 0.7 4.2 0.4 70 15 81 255 14.4 0.1 14.9 14.1 07/07/2005 00:10:00 2.8 0.9 4.9 0.7 2.6 1 4.9 0.4 1.9 0.9 4.6 0.4 58 18 44 255 14.6 0 15.2 14.4 07/07/2005 00:20:00 3.2 0.7 5.3 0.7 3 0.8 4.9 0.4 2.4 0.8 4.6 0.4 51 16 56 255 14.4 0.1 15.2 14.4 07/07/2005 00:30:00 3 0.6 4.9 1.9 2.8 0.6 4.9 1.5 2.5 0.6 4.2 0.7 44 12 47 255 14.4 0 15.2 14.4 07/07/2005 00:40:00 3.1 0.6 4.9 0.7 2.8 0.7 4.6 0.4 2.2 0.6 4.2 0.4 45 13 24 255 14.4 0 14.9 14.4 07/07/2005 00:50:00 2.9 0.6 4.9 1.5 2.6 0.7 4.9 0.7 2 0.6 3.8 0.4 54 13 58 255 14.1 0 14.6 13.8 07/07/2005 01:00:00 3.2 0.7 5.3 1.5 3 0.7 4.9 1.1 2.4 0.7 4.6 0.4 45 15 43 255 14.4 0 14.9 14.1 07/07/2005 01:10:00 3.5 0.7 4.9 1.5 3.3 0.9 4.9 0.7 2.5 0.7 4.2 1.1 62 12 69 255 14.6 0.1 15.2 14.6 07/07/2005 01:20:00 3.9 1 6.5 1.5 3.8 1 6.5 0.4 2.9 0.9 5.3 1.1 54 13 57 255 14.6 0 15.2 14.6 07/07/2005 01:30:00 3.8 0.8 6.1 1.9 3.7 0.9 6.1 1.5 2.8 0.8 4.9 0.4 51 15 37 255 14.6 0 14.9 14.6 07/07/2005 01:40:00 3.1 0.6 4.6 1.1 2.9 0.7 4.6 0.7 2.3 0.6 3.8 0.7 71 13 50 255 14.4 0 14.6 14.4 07/07/2005 01:50:00 2.7 0.5 3.8 1.5 2.4 0.6 4.2 0.7 1.9 0.7 3.8 0.4 70 11 71 255 14.1 0 14.6 13.8 07/07/2005 02:00:00 2.3 0.4 3.4 1.1 2.1 0.4 3.4 0.7 1.7 0.4 2.6 0.7 55 9 72 255 13.8 0 14.1 13.5 07/07/2005 02:10:00 2.8 0.5 3.8 1.5 2.6 0.6 3.8 1.1 2.2 0.6 3.4 1.1 53 11 40 255 13.7 0 14.4 13.5 07/07/2005 02:20:00 2.5 0.6 4.6 1.1 2.2 0.7 3.8 0.7 1.8 0.5 3.4 0.4 62 12 58 255 13.8 0 14.4 13.5 07/07/2005 02:30:00 2.5 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.6 0.6 3.4 0.4 76 12 54 255 13.6 0.1 14.1 13.3 07/07/2005 02:40:00 3.5 0.7 4.9 1.9 3.3 0.8 4.9 1.5 2.4 0.6 3.8 1.1 77 10 84 255 13.4 0 13.8 13.3 07/07/2005 02:50:00 3.8 0.7 5.7 2.3 3.7 0.7 5.7 1.5 2.7 0.6 4.6 1.5 75 9 77 255 13.5 0.1 14.4 13.3 07/07/2005 03:00:00 3.7 0.5 4.9 2.3 3.6 0.6 4.9 1.9 2.8 0.6 4.6 1.5 80 10 87 255 13.8 0 14.4 13.5 07/07/2005 03:10:00 3.9 0.7 5.7 1.9 3.7 0.7 5.3 1.9 2.7 0.7 4.2 0.7 76 12 79 255 13.5 0.1 14.4 13.3 07/07/2005 03:20:00 3.4 0.6 5.3 1.9 3.3 0.6 4.9 1.5 2.4 0.7 4.6 0.7 71 10 75 255 13.3 0 13.8 13 07/07/2005 03:30:00 3.6 0.7 5.7 2.3 3.5 0.8 5.7 1.5 2.8 0.8 4.2 0.7 70 14 62 255 12.9 0.1 13.5 12.7 07/07/2005 03:40:00 3 0.6 4.6 1.5 2.8 0.7 4.6 1.1 2.1 0.7 3.8 0.4 74 14 54 255 12.9 0 13.3 12.7 07/07/2005 03:50:00 3.8 0.9 6.8 1.9 3.7 1 7.2 1.5 2.9 0.9 5.7 1.1 61 15 36 255 13 0.2 13.8 12.7 07/07/2005 04:00:00 4.5 0.8 6.8 2.6 4.5 0.8 6.8 2.3 3.5 0.9 6.5 1.5 62 15 49 255 13.7 0 14.1 13.3 07/07/2005 04:10:00 4.7 1.2 8 1.9 4.5 1.3 7.6 1.5 3.8 1.2 6.8 0.7 63 17 42 255 13.9 0 14.4 13.8 07/07/2005 04:20:00 4.3 0.8 6.8 2.3 4.2 0.9 6.8 1.5 3.4 0.9 6.5 1.5 66 14 53 255 13.9 0 14.6 13.8 07/07/2005 04:30:00 4.2 1 6.5 1.9 4 1 6.5 1.5 3.3 1.1 5.7 1.1 68 15 58 255 14.1 0.1 14.6 13.8 07/07/2005 04:40:00 4.3 1 6.5 1.5 4.2 1.1 6.8 0.7 3.4 1 6.1 0.7 65 15 59 255 14.2 0 14.9 14.1 07/07/2005 04:50:00 4.2 1 7.6 1.5 4.1 1.1 7.2 1.5 3.2 1 5.7 1.1 58 16 53 255 14.4 0 14.6 14.4 07/07/2005 05:00:00 4.1 1 7.6 2.3 3.9 1.1 7.6 1.5 3.2 1 6.8 1.1 57 15 39 255 14.4 0 14.6 14.4 07/07/2005 05:10:00 3.7 0.9 6.1 1.9 3.6 1 6.5 1.5 3 1 6.1 0.7 59 17 50 255 14.5 0 14.6 14.4 07/07/2005 05:20:00 4.6 1.2 8.4 1.5 4.5 1.3 8.4 1.1 3.8 1.2 8.4 1.1 53 16 46 255 14.6 0 14.9 14.6 07/07/2005 05:30:00 4.2 1 6.5 1.9 4.1 1.2 6.8 0.7 3.5 1.1 5.7 0.7 52 16 40 255 14.4 0 14.9 14.4 07/07/2005 05:40:00 4 0.9 5.7 1.9 3.8 1 6.1 1.1 3.2 0.7 4.9 1.1 55 16 79 255 14.2 0 14.6 14.4 07/07/2005 05:50:00 3.4 0.9 5.7 1.1 3.3 1 5.7 0.7 2.7 0.8 5.3 0.4 53 17 71 255 14.9 0.2 15.5 14.6 07/07/2005 06:00:00 4.3 0.7 6.1 1.9 4.3 0.8 6.1 1.5 3.6 1 6.1 1.5 54 12 58 255 15.5 0 16 15.5 07/07/2005 06:10:00 4.2 1 6.8 1.5 4 1.1 6.5 1.1 3.5 1 6.1 0.7 51 16 37 255 15.1 0.1 16 15.2 07/07/2005 06:20:00 3.7 0.7 5.7 1.9 3.5 0.8 5.7 1.5 2.7 0.7 4.6 0.4 54 15 53 255 15 0 15.7 14.9 07/07/2005 06:30:00 2.9 0.9 4.9 1.1 2.7 1 4.9 0.4 2.2 0.9 4.6 0.4 67 16 48 255 14.8 0 15.2 14.6 07/07/2005 06:40:00 3.1 0.7 4.9 1.5 3 0.8 5.3 1.1 2.5 0.8 4.6 0.7 76 14 52 255 15 0 15.5 14.9 07/07/2005 06:50:00 3 1 5.3 1.1 2.9 1.1 5.7 0.4 2.5 1 5.3 0.4 60 20 49 255 15 0 15.7 15.2 07/07/2005 07:00:00 3 0.7 4.9 1.5 2.8 0.8 4.9 0.7 2.2 0.8 4.2 0.4 67 17 77 255 15.1 0.1 15.7 15.2 07/07/2005 07:10:00 3.6 0.8 5.3 1.5 3.5 0.9 5.3 1.1 2.9 1 5.3 0.4 57 16 60 255 15.7 0.4 16.8 15.2 07/07/2005 07:20:00 3.8 1.1 6.8 1.5 3.8 1.1 6.8 1.5 3.1 1.1 5.7 0.4 47 18 51 255 17.2 0.3 17.7 16.6 07/07/2005 07:30:00 3.5 0.9 5.3 0.7 3.5 0.9 5.3 0.4 2.7 1 4.9 0.4 45 17 52 255 18.3 0.2 18.8 17.7 07/07/2005 07:40:00 4.2 0.8 6.1 1.9 4.1 0.9 6.1 1.5 3.5 0.9 5.7 1.1 46 15 45 255 18.7 0 19.1 18.5 07/07/2005 07:50:00 3.9 0.9 5.7 1.5 3.9 1 6.1 1.1 3.4 1 5.7 1.1 43 13 44 255 18.4 0 18.8 18 07/07/2005 08:00:00 3.8 0.7 5.3 1.9 3.8 0.7 5.3 1.5 3.2 0.8 4.9 1.1 41 12 44 255 18.2 0 18.8 18 07/07/2005 08:10:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.1 3 0.7 4.6 1.1 33 13 40 255 18.3 0 18.8 18 07/07/2005 08:20:00 2.8 0.6 3.8 0.7 2.7 0.7 4.2 0.7 2.5 0.7 4.2 0.7 41 17 64 255 18.7 0 19.4 18.2 07/07/2005 08:30:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.1 2.3 0.5 3.8 0.7 52 15 51 255 19 0.1 19.4 18.8 07/07/2005 08:40:00 2.3 0.5 3.4 1.1 2.1 0.5 3 0.7 1.9 0.6 3.4 0.4 32 17 20 255 19.6 0.2 20.3 19.1 07/07/2005 08:50:00 1.8 0.5 3.8 0.4 1.6 0.6 3.4 0.4 1.5 0.5 3 0.4 35 20 55 255 20 0.2 20.5 19.4 07/07/2005 09:00:00 1.1 0.5 2.6 0.4 0.8 0.5 1.9 0.4 0.9 0.5 2.3 0.4 47 36 59 255 20.2 0 20.5 20 07/07/2005 09:10:00 1.2 0.4 2.3 0.4 0.9 0.4 2.3 0.4 1 0.5 2.3 0.4 19 36 24 255 20.2 0.2 20.8 20 07/07/2005 09:20:00 1.1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 11 22 347 255 21.1 0.2 21.4 20.8 07/07/2005 09:30:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 46 23 37 255 21.2 0 21.4 21.1 07/07/2005 09:40:00 1 0.5 1.9 0.4 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 82 39 63 255 21.6 0.1 22.3 21.1 07/07/2005 09:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.4 2.3 0.4 47 32 22 255 21.8 0 22.3 21.7 07/07/2005 10:00:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.6 2.3 0.4 16 45 47 255 22.1 0.4 23.2 21.7 07/07/2005 10:10:00 1.4 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.2 0.6 2.6 0.4 34 39 346 255 22.8 0 23.5 22.9 07/07/2005 10:20:00 1 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 28 30 6 255 22.9 0.1 23.5 22.9 07/07/2005 10:30:00 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 84 45 124 255 22.8 0 23.5 22.6 07/07/2005 10:40:00 1.3 0.6 3.4 0.4 1.2 0.7 3 0.4 1.2 0.6 2.6 0.4 57 24 30 255 23.2 0.1 23.5 22.9 07/07/2005 10:50:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 1.1 0.7 3 0.4 24 56 345 255 23.2 0 23.5 22.9 07/07/2005 11:00:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 1.3 0.6 3 0.4 321 51 19 255 24 0.1 24.4 23.5 07/07/2005 11:10:00 2.3 1 4.9 0.4 2.3 1.1 4.9 0.4 1.9 1 4.6 0.4 278 58 264 255 24.2 0.1 24.4 23.8 07/07/2005 11:20:00 1.4 0.6 3.4 0.4 1.3 0.7 3 0.4 1.2 0.6 3 0.4 271 47 290 255 23.8 0.2 24.4 23.5 07/07/2005 11:30:00 1.6 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.1 0.7 3 0.4 298 64 313 255 24.7 0 25 24.4 07/07/2005 11:40:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 1.8 1 4.2 0.4 276 39 327 255 24.9 0 25 24.7 07/07/2005 11:50:00 2.4 0.7 4.6 0.4 2.4 0.8 4.6 0.4 1.9 0.9 4.6 0.4 260 35 252 255 24.9 0 25 24.7 07/07/2005 12:00:00 2.7 1.1 5.7 0.4 2.4 1.2 5.7 0.4 2.1 1.2 5.3 0.4 300 28 291 255 24.7 0.2 25.3 24.4 07/07/2005 12:10:00 2.4 1.2 5.3 0.4 2.3 1.3 4.6 0.4 2.3 1.2 5.3 0.4 286 41 323 255 24.6 0 25 24.4 07/07/2005 12:20:00 2.9 0.9 6.5 0.7 2.9 0.9 5.7 0.7 2.5 1 5.3 0.4 268 38 275 255 25 0 25.3 25 07/07/2005 12:30:00 3.4 1.1 6.5 0.7 3.4 1.2 6.1 0.4 3.1 1 6.1 0.7 285 30 255 255 25.3 0 25.6 25.3 07/07/2005 12:40:00 3.3 1.5 6.8 0.4 3.2 1.5 6.5 0.4 3 1.5 6.8 0.4 268 26 250 255 25 0.2 25.6 24.7 07/07/2005 12:50:00 3.5 1.1 5.7 0.7 3.4 1.1 5.7 0.4 3 1 6.1 0.7 265 24 260 255 24.7 0.1 25.3 24.7 07/07/2005 13:00:00 3.4 1 6.1 1.1 3.4 1 6.1 1.1 2.9 1.1 6.8 0.4 262 33 255 255 24.8 0 25.3 24.7 07/07/2005 13:10:00 3.4 1.4 6.5 0.4 3.3 1.5 6.5 0.4 3 1.5 6.8 0.4 289 33 294 255 25.3 0.1 25.6 25 07/07/2005 13:20:00 3.6 1 5.7 0.7 3.6 1 5.7 0.4 3 1 5.7 0.7 273 22 283 255 25.5 0 25.9 25.3 07/07/2005 13:30:00 3.9 1.1 6.5 1.1 3.9 1.2 6.8 0.7 3.3 1.1 6.1 0.7 294 32 268 255 26.3 0.1 26.5 25.9 07/07/2005 13:40:00 3.5 1.2 6.1 0.7 3.5 1.2 6.5 0.4 3.1 1.2 6.1 0.4 294 22 288 255 26.8 0 27.1 26.5 07/07/2005 13:50:00 3.3 1.1 7.2 1.5 3.3 1.2 7.2 1.1 2.9 1.2 7.2 0.4 289 20 279 255 26.3 0.2 26.8 26.2 07/07/2005 14:00:00 3.8 1.1 6.5 1.1 3.8 1.2 6.8 1.1 3.4 1.2 6.8 1.1 294 22 283 255 25.3 0.5 26.8 25 07/07/2005 14:10:00 3.3 1.3 7.2 0.4 3.2 1.3 7.2 0.4 2.9 1.3 6.5 0.4 307 36 284 255 25.7 0.2 26.5 25.6 07/07/2005 14:20:00 2.6 1.2 5.7 0.4 2.5 1.2 4.9 0.4 1.9 1.1 6.1 0.4 298 36 314 255 26.2 0 26.5 25.9 07/07/2005 14:30:00 4.1 1.7 8 0.4 4.1 1.7 8 0.4 3.6 1.7 7.6 0.4 112 76 125 255 24.4 1.2 26.2 22.6 07/07/2005 14:40:00 4 0.8 6.1 1.5 4 0.7 6.1 1.9 3.3 0.9 5.3 1.1 98 12 87 255 21.7 0.2 22.6 21.4 07/07/2005 14:50:00 2.6 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.3 0.4 3.4 1.1 80 19 104 255 21.7 0.1 22 21.4 07/07/2005 15:00:00 2.4 0.5 3.8 0.7 2.3 0.5 3.4 0.7 2 0.6 3.4 0.7 50 17 30 255 22.2 0.1 22.6 21.7 07/07/2005 15:10:00 0.8 0.6 2.6 0.4 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 67 26 62 255 22.6 0.2 23.5 22.3 07/07/2005 15:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 100 16 136 255 23.3 0.3 23.8 22.9 07/07/2005 15:30:00 2.1 1.1 4.9 0.4 2 1.2 5.3 0.4 2 1 4.6 0.4 29 27 7 255 24.9 0.5 25.6 23.8 07/07/2005 15:40:00 3.6 0.5 4.9 1.9 3.6 0.6 4.9 1.9 3.2 0.7 4.6 1.5 30 15 11 255 25.9 0.2 26.5 25.6 07/07/2005 15:50:00 3.1 0.6 4.6 1.5 3.1 0.6 4.9 1.5 2.5 0.6 4.2 1.1 18 22 3 255 26.5 0.2 26.8 26.2 07/07/2005 16:00:00 3.1 0.9 4.6 0.7 3 1 4.6 0.4 2.4 0.9 4.6 0.4 10 17 2 255 26 0.5 26.8 25.3 07/07/2005 16:10:00 2.6 0.5 4.2 1.1 2.3 0.6 4.2 1.1 1.9 0.7 3.4 0.4 349 17 351 255 25 0 25.6 25 07/07/2005 16:20:00 2.8 0.5 4.2 1.5 2.7 0.6 4.2 1.5 2 0.8 3.8 0.4 355 13 9 255 26.3 0.3 26.5 25.6 07/07/2005 16:30:00 2.2 0.8 3.8 0.4 2.1 0.9 3.8 0.4 1.9 0.8 3.8 0.4 5 24 22 255 26.6 0 27.1 26.5 07/07/2005 16:40:00 2.1 0.6 3.8 0.7 2 0.7 3.8 0.4 1.6 0.7 3.4 0.4 356 30 23 255 25.9 0.4 26.5 25.3 07/07/2005 16:50:00 3 0.6 4.6 1.5 2.7 0.6 4.2 1.5 2.4 0.7 4.2 0.7 331 18 301 255 24.7 0.2 25.3 24.4 07/07/2005 17:00:00 2.9 1.2 5.7 1.1 2.7 1.2 5.3 0.4 2.2 1.1 5.3 0.4 315 32 293 255 24.4 0 24.7 24.1 07/07/2005 17:10:00 3.6 1.1 6.1 1.1 3.5 1.1 6.1 1.1 2.7 1 5.7 0.7 269 27 289 255 23.8 0 24.4 23.5 07/07/2005 17:20:00 1.9 0.9 3.8 0.4 1.8 1 4.2 0.4 1.6 0.8 3.8 0.4 272 30 270 255 23.5 0 23.8 23.5 07/07/2005 17:30:00 3.4 3.1 10.3 0.4 3.4 3.1 10.3 0.4 3 2.7 10.3 0.4 118 86 68 255 23 0.5 23.5 21.7 07/07/2005 17:40:00 6.9 1.9 11.8 2.6 6.9 1.9 11.8 3 5.8 2 10.7 1.5 85 19 81 255 20.5 0.7 21.7 19.4 07/07/2005 17:50:00 4.7 1.3 8.8 2.3 4.7 1.3 8.8 1.9 4 1.3 8.4 0.7 99 20 81 255 19.1 0.1 19.7 18.5 07/07/2005 18:00:00 4.6 1.4 7.6 0.4 4.6 1.3 7.2 0.7 4.1 1.4 8 0.7 96 21 106 255 18.5 0.1 18.8 18 07/07/2005 18:10:00 5.3 1.3 9.1 2.3 5.3 1.3 9.1 2.3 4.6 1.2 8 1.9 102 19 119 255 17.9 0.2 18.8 17.4 07/07/2005 18:20:00 7.2 1.6 11.1 2.3 7.1 1.5 10.7 2.3 6.1 1.6 10.7 1.9 110 22 83 255 17.1 0.2 18 16.8 07/07/2005 18:30:00 5.1 1.8 10.3 1.5 5.2 1.7 9.9 1.5 4.2 1.7 10.7 1.1 85 24 89 255 17.2 0 17.7 16.8 07/07/2005 18:40:00 5.9 1.2 9.1 2.6 5.9 1.2 9.5 2.6 4.8 1.1 8.4 1.5 100 20 90 255 16.5 0.4 17.1 16 07/07/2005 18:50:00 5.1 1.3 9.1 1.5 5 1.3 8.8 1.5 4 1.2 8.4 1.5 112 22 96 255 16 0 16.3 16 07/07/2005 19:00:00 3.6 1.1 6.1 1.1 3.5 1.1 6.1 1.1 2.8 1.1 6.1 0.4 125 26 86 255 16.3 0 16.6 16 07/07/2005 19:10:00 3.3 0.8 5.7 1.5 3.3 0.7 5.3 1.5 2.8 0.7 5.3 1.1 124 22 141 255 16.6 0 16.8 16.6 07/07/2005 19:20:00 3.8 0.8 5.3 1.5 3.7 0.8 5.7 1.9 3 0.7 4.9 1.1 93 17 97 255 16.7 0 16.8 16.6 07/07/2005 19:30:00 3.6 0.8 5.3 1.5 3.5 0.8 5.3 1.1 3 0.7 5.3 0.7 71 21 51 255 17.1 0 17.1 16.8 07/07/2005 19:40:00 3.4 1 6.8 0.7 3.3 1.1 6.8 0.4 2.7 0.9 5.3 0.4 78 16 85 255 17.2 0 17.4 17.1 07/07/2005 19:50:00 3.7 0.9 6.1 1.9 3.7 0.9 6.5 1.5 3.1 1 5.7 1.1 73 19 60 255 17.4 0 17.7 17.1 07/07/2005 20:00:00 3.9 1 5.7 0.7 3.7 1.1 6.1 0.4 3.3 1 5.3 1.1 62 18 59 255 17.8 0 18 17.4 07/07/2005 20:10:00 3.5 0.7 5.3 1.9 3.4 0.8 5.7 1.9 3 1 5.3 0.7 61 20 46 255 17.8 0 18 17.4 07/07/2005 20:20:00 4.3 1 6.5 1.9 4.3 1 6.8 1.1 3.7 1.1 6.8 1.1 66 15 68 255 17.4 0.1 17.7 17.1 07/07/2005 20:30:00 3.8 0.8 6.1 1.9 3.7 0.9 6.1 1.9 3.1 1 5.7 1.1 65 17 73 255 16.8 0 17.1 16.8 07/07/2005 20:40:00 5.7 1.5 9.9 2.3 5.7 1.5 9.9 1.9 4.8 1.4 8 1.1 53 17 49 255 16.6 0 16.8 16.6 07/07/2005 20:50:00 6.8 1.5 10.7 3 6.7 1.7 11.1 2.3 5.6 1.5 11.1 1.5 49 16 48 255 16.2 0.1 16.8 16 07/07/2005 21:00:00 5.9 1.4 10.3 3 6 1.5 10.3 3 4.7 1.5 9.1 1.5 52 17 38 255 15.7 0 16.3 15.7 07/07/2005 21:10:00 5.2 1.3 8 2.3 5.2 1.3 8 1.5 4.3 1.1 7.2 1.9 54 15 62 255 15.7 0 16 15.7 07/07/2005 21:20:00 5.2 1 8 2.6 5.1 1.1 7.6 2.6 4.3 1 6.8 1.5 59 15 48 255 15.9 0 16.3 15.7 07/07/2005 21:30:00 4.8 1.1 7.6 1.9 4.8 1.1 7.6 2.3 4.1 1 7.6 1.5 57 17 48 255 16 0 16.3 16 07/07/2005 21:40:00 5.4 1.3 8.8 2.6 5.4 1.3 9.1 2.3 4.5 1.2 8.8 2.3 57 15 33 255 16.1 0 16.6 16 07/07/2005 21:50:00 5.2 1.2 8 2.6 5.2 1.3 8.4 2.3 4.4 1.2 7.6 1.9 51 15 45 255 16.2 0 16.6 16.3 07/07/2005 22:00:00 5.2 1.4 8.4 2.3 5.1 1.4 8.8 2.3 4.1 1.3 7.2 1.1 59 20 48 255 16.5 0 16.8 16.3 07/07/2005 22:10:00 4.3 1 7.6 2.3 4.3 1 7.2 1.9 3.4 0.9 6.1 1.5 72 16 99 255 16.3 0.1 16.8 16 07/07/2005 22:20:00 5.1 1 7.6 2.6 5.1 1.1 8 2.3 4.1 1.1 7.6 1.9 53 13 55 255 16.1 0 16.6 16 07/07/2005 22:30:00 5.2 0.9 8 2.6 5.2 0.9 8.4 3 4.2 1 7.2 2.3 53 15 45 255 16.4 0 16.8 16.3 07/07/2005 22:40:00 4.6 1.2 7.6 1.5 4.5 1.2 7.6 2.3 3.6 1.2 7.2 1.1 76 17 61 255 16.6 0 16.8 16.6 07/07/2005 22:50:00 4.3 1 7.2 1.9 4.2 1 7.6 1.5 3.4 1 5.3 1.1 72 16 61 255 16.6 0 16.8 16.3 07/07/2005 23:00:00 4.6 1.2 8 2.3 4.5 1.2 8 1.9 3.9 1.2 7.2 1.1 60 17 72 255 16.4 0 16.8 16.3 07/07/2005 23:10:00 4.6 1.2 7.6 2.3 4.5 1.3 7.6 1.5 3.7 1.2 7.2 1.5 64 16 62 255 16.1 0 16.8 16.3 07/07/2005 23:20:00 5 1.3 8.4 2.6 5 1.3 8.4 2.3 4.1 1.1 7.6 1.5 59 18 28 255 16.2 0 16.8 16.3 07/07/2005 23:30:00 4 1.2 7.6 1.5 4 1.3 7.6 1.1 3.3 1.1 6.8 0.7 63 15 45 255 16.2 0 16.8 16 07/07/2005 23:40:00 4.6 1.2 8 1.5 4.6 1.2 8 1.9 3.9 1.1 7.6 0.7 61 17 44 255 15.9 0 16.6 15.7 07/07/2005 23:50:00 4.6 1.3 8.4 1.5 4.6 1.3 8.4 1.1 3.9 1.2 8 1.5 56 17 65 255 15.6 0 16 15.5 07/08/2005 00:00:00 4.5 1 7.2 2.3 4.4 1 7.6 2.3 3.6 1 6.5 1.9 56 16 61 255 15.2 0 15.7 15.2 07/08/2005 00:10:00 3.8 0.9 6.5 1.9 3.7 1 6.1 1.5 3 0.9 5.3 1.1 53 15 42 255 15 0 15.7 14.9 07/08/2005 00:20:00 4.5 1.1 7.6 2.6 4.5 1.2 7.6 2.3 3.3 1.2 7.6 1.1 71 17 95 255 15 0 15.7 14.9 07/08/2005 00:30:00 4 0.9 6.5 1.9 4 1 6.5 1.5 3.1 0.9 6.1 1.1 66 17 34 255 15.3 0 16 15.2 07/08/2005 00:40:00 4.3 0.9 6.8 1.9 4.2 1 6.8 1.9 3.5 0.9 6.1 1.1 68 20 66 255 15.6 0 16 15.5 07/08/2005 00:50:00 3.7 0.8 6.1 1.9 3.5 0.8 5.7 1.5 2.9 0.9 5.3 0.7 78 13 80 255 15.5 0 16 15.2 07/08/2005 01:00:00 3.5 0.7 5.7 1.9 3.4 0.7 5.3 1.9 2.9 0.7 4.6 0.7 79 15 68 255 15.2 0.1 15.7 15.2 07/08/2005 01:10:00 3.6 0.8 5.3 1.5 3.4 0.8 5.7 1.1 2.6 0.8 4.9 0.7 73 16 78 255 15 0 15.5 14.9 07/08/2005 01:20:00 3.8 0.9 6.1 1.5 3.6 1 6.1 1.5 2.9 0.8 4.9 1.1 82 15 78 255 14.6 0.1 15.2 14.4 07/08/2005 01:30:00 3.4 0.8 5.7 1.9 3.3 0.9 5.7 1.1 2.5 0.8 4.9 0.4 76 14 68 255 14.2 0.1 14.9 14.1 07/08/2005 01:40:00 3 0.6 4.9 1.1 2.9 0.7 4.6 0.4 2.2 0.6 3.8 0.4 72 15 85 255 13.9 0 14.6 13.5 07/08/2005 01:50:00 3.1 0.7 4.9 1.5 3 0.8 4.9 1.1 2.2 0.7 4.2 0.7 71 9 76 255 13.6 0.2 14.4 13.3 07/08/2005 02:00:00 4.3 0.7 6.1 1.9 4.2 0.7 6.1 1.5 3 0.8 4.9 0.4 85 12 98 255 13.2 0.1 13.8 13 07/08/2005 02:10:00 3.9 0.7 5.7 2.3 3.8 0.7 5.7 2.3 2.9 0.7 4.6 1.1 85 13 99 255 13.2 0 13.5 13 07/08/2005 02:20:00 3.8 0.6 5.3 1.9 3.7 0.6 5.3 1.9 2.7 0.6 4.2 1.1 94 11 86 255 13.3 0 13.5 13 07/08/2005 02:30:00 3.5 0.6 5.7 2.3 3.3 0.7 5.3 1.9 2.6 0.6 4.2 1.1 92 10 90 255 13.1 0 13.5 13 07/08/2005 02:40:00 2.9 0.3 3.8 2.3 2.7 0.4 3.8 1.5 2.2 0.5 3.4 0.4 94 9 88 255 12.9 0 13.3 12.7 07/08/2005 02:50:00 3.5 0.6 4.9 1.5 3.4 0.7 4.9 1.9 2.5 0.7 4.2 0.7 105 12 100 255 12.7 0 13 12.5 07/08/2005 03:00:00 4.2 0.6 6.5 2.6 4.1 0.7 6.8 1.9 3 0.7 5.3 1.5 107 12 109 255 12.9 0 13.3 12.7 07/08/2005 03:10:00 4 0.5 5.3 2.3 3.9 0.5 5.3 2.3 3 0.6 4.2 1.5 104 11 106 255 12.9 0 13.3 12.7 07/08/2005 03:20:00 3.8 0.7 4.9 1.5 3.7 0.8 4.9 1.1 2.6 0.8 4.2 1.1 109 13 104 255 12.8 0 13.3 12.7 07/08/2005 03:30:00 3.8 0.6 5.3 2.3 3.6 0.6 4.9 2.3 2.6 0.5 4.2 1.5 105 12 105 255 12.7 0 13.3 12.7 07/08/2005 03:40:00 3.6 0.5 5.3 2.3 3.5 0.5 4.9 1.9 2.7 0.6 3.8 0.7 99 11 110 255 12.7 0 13 12.5 07/08/2005 03:50:00 3.6 0.5 5.3 2.6 3.5 0.5 5.3 2.3 2.8 0.6 4.9 1.5 101 9 99 255 12.7 0 12.7 12.5 07/08/2005 04:00:00 4.1 0.5 5.3 2.6 4.1 0.4 5.3 2.3 3.1 0.6 4.9 1.5 103 9 103 255 12.5 0 13 12.5 07/08/2005 04:10:00 3.5 0.6 4.9 1.9 3.4 0.7 4.9 1.5 2.6 0.7 4.6 1.1 111 11 106 255 12.7 0 13 12.5 07/08/2005 04:20:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 1.9 2.6 0.6 4.2 1.1 120 12 113 255 12.5 0.1 13 12.5 07/08/2005 04:30:00 3.3 0.7 4.6 1.5 3.1 0.7 4.9 0.7 2.4 0.7 4.6 1.1 120 15 118 255 12.5 0 12.7 12.5 07/08/2005 04:40:00 3.5 0.7 5.7 1.9 3.4 0.8 5.7 1.5 2.6 0.7 4.6 1.1 122 15 122 255 12.8 0.2 13 12.5 07/08/2005 04:50:00 2.8 0.7 4.6 1.1 2.5 0.7 4.2 0.4 2.1 0.6 3.8 0.7 117 16 129 255 12.9 0 13 12.7 07/08/2005 05:00:00 2.1 0.9 4.6 0.4 1.7 1 4.2 0.4 1.3 0.7 3.4 0.4 118 23 100 255 13.1 0 13.5 12.7 07/08/2005 05:10:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 215 53 126 255 13.5 0.2 14.4 13.3 07/08/2005 05:20:00 0.9 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 66 28 100 255 13.5 0.3 14.4 13 07/08/2005 05:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 124 13 99 255 13.3 0.1 13.8 13 07/08/2005 05:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.5 0.4 89 36 77 255 13.6 0.2 14.6 13.3 07/08/2005 05:50:00 1.7 0.6 3.8 0.7 1.4 0.6 3 0.4 1.4 0.5 3 0.4 48 19 35 255 14.6 0.3 15.5 14.1 07/08/2005 06:00:00 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.4 2 0.6 3.8 0.4 62 17 74 255 15.6 0.3 16.3 15.2 07/08/2005 06:10:00 2.1 0.7 3.4 0.4 1.9 0.8 3.4 0.4 1.9 0.7 3.8 0.4 46 26 25 255 16.1 0 16.8 16 07/08/2005 06:20:00 1.2 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 32 17 8 255 16.4 0.2 17.1 16 07/08/2005 06:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 1.9 0.4 40 15 18 255 17 0.2 17.4 16.8 07/08/2005 06:40:00 1.1 0.7 2.6 0.4 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 114 24 138 255 17.4 0.1 17.7 16.8 07/08/2005 06:50:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 136 12 116 255 16.9 0 17.1 16.8 07/08/2005 07:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 133 0 133 255 17.5 0.2 18.2 16.8 07/08/2005 07:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 133 8 133 255 18 0.2 18.5 17.4 07/08/2005 07:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 120 19 126 255 18.2 0.1 18.8 18 07/08/2005 07:30:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 122 8 126 255 18.2 0.2 18.8 17.7 07/08/2005 07:40:00 0.5 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.5 0.4 112 53 41 255 19.2 0.2 20 18.5 07/08/2005 07:50:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 13 22 34 255 19.5 0.1 20 19.4 07/08/2005 08:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 122 53 140 255 19.5 0 20 19.1 07/08/2005 08:10:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 71 28 86 255 20.1 0 20.5 20 07/08/2005 08:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 33 35 15 255 20 0 20.5 20 07/08/2005 08:30:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 111 86 214 255 20.3 0.2 20.8 20 07/08/2005 08:40:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 255 38 267 255 20.8 0 21.1 20.5 07/08/2005 08:50:00 1.8 0.4 3 0.7 1.7 0.5 3 0.4 1.6 0.5 3.4 0.4 249 24 255 255 21 0 21.4 20.8 07/08/2005 09:00:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.7 0.7 3.8 0.4 241 27 229 255 21.3 0.2 22 20.8 07/08/2005 09:10:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.4 0.6 3.4 0.4 297 51 256 255 21.6 0.1 22 21.1 07/08/2005 09:20:00 1.9 1 3.8 0.4 1.7 1 3.8 0.4 1.5 1 4.2 0.4 342 36 330 255 21.7 0.2 22.3 21.1 07/08/2005 09:30:00 2.8 1 4.9 1.1 2.7 1 4.6 0.4 2.6 1 4.6 0.7 292 28 304 255 21.7 0.1 22.3 21.4 07/08/2005 09:40:00 2.2 1.1 4.6 0.4 2 1.2 4.2 0.4 1.9 1 4.2 0.4 287 64 269 255 21.7 0.2 22.3 21.1 07/08/2005 09:50:00 2.5 1.5 6.1 0.4 2.5 1.5 5.3 0.4 2.2 1.3 4.6 0.4 256 69 315 255 22 0.2 22.3 21.7 07/08/2005 10:00:00 2.8 1 5.7 0.7 2.7 1.1 5.7 0.4 2.4 1.2 5.7 0.4 285 32 315 255 21.9 0.1 22.3 21.7 07/08/2005 10:10:00 3.2 0.9 5.3 1.1 3.1 0.9 5.7 0.7 2.8 1 4.9 0.7 293 20 312 255 22.3 0 22.9 22 07/08/2005 10:20:00 3.6 0.9 6.1 0.7 3.6 0.9 6.5 1.5 3.1 1 5.7 0.4 277 30 304 255 22.6 0 22.9 22.3 07/08/2005 10:30:00 2.9 1.2 6.5 0.4 2.7 1.2 6.1 0.4 2.3 1.1 6.1 0.4 274 38 320 255 22.8 0 23.2 22.6 07/08/2005 10:40:00 3.4 1 5.7 1.1 3.3 1.1 5.3 1.1 3 1.1 5.7 0.7 279 32 300 255 22.8 0 23.2 22.6 07/08/2005 10:50:00 3 1.7 6.5 0.4 2.8 1.7 6.5 0.4 2.6 1.6 6.1 0.4 295 30 322 255 22.4 0 22.9 22.3 07/08/2005 11:00:00 1.9 1.2 4.6 0.4 1.7 1.3 4.6 0.4 1.7 1.1 4.9 0.4 275 51 294 255 22.7 0.1 23.2 22.3 07/08/2005 11:10:00 3.3 1 5.7 1.5 3.2 1 5.7 1.1 2.9 1 5.7 1.1 274 27 274 255 22.8 0 23.2 22.6 07/08/2005 11:20:00 3.1 1 5.7 0.7 3 1 5.3 0.4 2.7 1 4.9 0.7 274 45 251 255 23.1 0 23.5 22.9 07/08/2005 11:30:00 3.2 1.3 6.1 0.4 3 1.4 5.7 0.4 2.4 1.2 5.7 0.4 286 43 229 255 23.6 0.1 24.1 23.5 07/08/2005 11:40:00 3.1 1 5.7 0.7 2.9 1 5.7 0.4 2.4 1 4.9 0.4 278 30 280 255 23.6 0.1 23.8 23.5 07/08/2005 11:50:00 3.1 1 5.7 1.1 3 1 5.7 0.4 2.7 1.1 6.5 0.4 268 30 279 255 23.6 0.4 24.1 22.9 07/08/2005 12:00:00 3 1.2 6.5 0.4 3 1.2 6.8 0.4 2.6 1.2 6.5 0.4 264 30 310 255 23.4 0.1 23.8 22.9 07/08/2005 12:10:00 4.2 1.2 6.8 1.5 4.1 1.2 6.8 0.4 3.6 1.2 6.8 1.1 300 20 301 255 23.7 0 24.1 23.5 07/08/2005 12:20:00 3.7 1.1 6.8 0.7 3.6 1.1 6.5 1.1 3.2 1.2 6.1 0.4 285 32 325 255 24.1 0.2 24.7 23.8 07/08/2005 12:30:00 3.7 1.3 6.1 0.4 3.6 1.4 6.1 0.4 3 1.6 6.1 0.4 285 27 275 255 24.1 0.2 24.7 23.8 07/08/2005 12:40:00 3.7 0.8 5.7 1.1 3.7 0.8 5.3 1.1 3.1 1 5.3 0.4 293 21 321 255 24.1 0 24.4 24.1 07/08/2005 12:50:00 3.1 1.3 6.8 0.4 2.9 1.2 6.5 0.4 2.4 1.3 5.7 0.4 300 41 314 255 24.3 0.2 25 23.8 07/08/2005 13:00:00 3.4 1.2 6.8 0.4 3.4 1.2 6.5 0.4 2.7 1.3 6.1 0.4 283 32 290 255 24.5 0 25 24.4 07/08/2005 13:10:00 3.8 1.1 6.8 1.1 3.7 1.1 6.5 1.1 3.2 1.1 5.7 0.7 292 23 280 255 24.6 0 25 24.4 07/08/2005 13:20:00 4.1 1.1 6.8 1.9 4 1.1 6.8 0.7 3.4 1.2 6.1 0.4 292 24 270 255 24.5 0 25 24.4 07/08/2005 13:30:00 4.5 1.3 8 1.1 4.4 1.4 7.6 0.4 3.8 1.2 6.8 0.7 288 22 303 255 24.4 0.4 25 23.8 07/08/2005 13:40:00 3.2 1.1 6.5 0.7 3.2 1.2 6.5 0.7 2.7 1.2 6.5 0.4 276 30 264 255 24.6 0.2 25 24.1 07/08/2005 13:50:00 4 1.1 6.5 1.1 3.8 1.2 6.5 0.4 3.3 1.1 5.7 0.7 296 32 248 255 25 0 25.3 25 07/08/2005 14:00:00 4.2 1.2 7.6 1.5 4.1 1.2 6.5 1.5 3.3 1.2 6.1 0.7 282 28 265 255 25 0 25.3 25 07/08/2005 14:10:00 3.9 1.3 6.8 0.7 3.8 1.4 6.8 0.4 3.2 1.3 6.5 0.4 286 29 288 255 25.2 0 25.3 25 07/08/2005 14:20:00 5.2 1.2 8 1.9 5.1 1.2 8 1.5 4.4 1.3 7.6 1.1 290 20 283 255 24.8 0 25.3 24.4 07/08/2005 14:30:00 3.7 1.6 7.6 0.4 3.5 1.6 7.6 0.4 2.9 1.7 7.6 0.4 288 41 303 255 25 0.1 25.6 25 07/08/2005 14:40:00 3.9 1.1 6.5 1.5 3.8 1.2 6.5 1.1 2.9 1.2 6.1 0.4 295 26 310 255 25.6 0 25.9 25.3 07/08/2005 14:50:00 4.3 1 6.8 1.5 4.1 1 7.2 1.5 3.4 1.3 6.5 0.7 294 22 305 255 25.5 0.3 25.9 25 07/08/2005 15:00:00 4 1.3 6.8 1.5 3.9 1.4 6.8 1.1 3.4 1.2 7.2 0.4 286 22 279 255 24.9 0 25.3 24.7 07/08/2005 15:10:00 3.7 1.3 6.8 0.4 3.6 1.4 6.8 0.4 2.9 1.4 6.8 0.4 284 26 281 255 25 0.4 25.6 24.4 07/08/2005 15:20:00 3.5 1.1 6.1 0.7 3.4 1.2 6.1 0.4 2.8 1.2 5.7 0.4 289 29 279 255 24.1 0 24.4 23.8 07/08/2005 15:30:00 3.9 1.3 6.5 0.7 3.8 1.3 6.5 0.4 3.1 1.3 5.7 0.7 283 22 277 255 24.8 0 25 24.4 07/08/2005 15:40:00 4.2 1.5 7.6 1.5 4.1 1.6 7.6 1.1 3.5 1.5 7.2 0.7 283 23 265 255 24.7 0.1 25 24.4 07/08/2005 15:50:00 3.8 1.4 8.4 1.1 3.6 1.5 8.8 0.4 3.1 1.3 8 0.7 279 27 277 255 25 0.1 25.3 24.7 07/08/2005 16:00:00 4.6 1.3 8 1.1 4.4 1.3 8 1.1 3.7 1.5 7.6 0.7 288 21 294 255 25 0 25.3 24.7 07/08/2005 16:10:00 3.9 1.1 6.5 1.9 3.7 1.2 6.8 1.5 3.1 1.3 6.5 0.4 286 26 269 255 25 0 25.3 24.7 07/08/2005 16:20:00 4.1 1.1 6.8 1.5 4 1.2 7.6 1.1 3.2 1.2 6.8 0.4 287 24 264 255 24.4 0 24.7 24.4 07/08/2005 16:30:00 4 1.3 6.8 0.7 3.9 1.3 7.2 0.7 3.1 1.2 6.1 0.7 276 28 281 255 24.5 0 24.7 24.4 07/08/2005 16:40:00 4.7 1.1 8 2.3 4.5 1.1 7.6 2.3 3.9 1.2 6.8 0.7 283 18 288 255 24.4 0.2 24.7 24.1 07/08/2005 16:50:00 3.3 1.3 6.8 0.4 3.1 1.3 6.5 0.4 2.8 1.5 6.5 0.4 270 45 254 255 24.4 0 24.7 24.1 07/08/2005 17:00:00 3.7 1.2 6.8 0.7 3.6 1.3 7.2 0.4 2.9 1.3 6.1 0.4 280 27 261 255 24.3 0.2 24.7 23.8 07/08/2005 17:10:00 3.7 1.1 6.1 1.5 3.6 1.2 6.5 0.7 3.2 1.3 6.1 0.4 275 23 253 255 23.6 0 23.8 23.2 07/08/2005 17:20:00 3.4 1.2 6.5 0.7 3.4 1.2 6.8 0.4 2.7 1.2 6.8 0.4 278 24 289 255 22.8 0.1 23.5 22.3 07/08/2005 17:30:00 3.9 1.3 6.8 0.7 3.7 1.3 6.8 0.4 3 1.3 6.8 0.7 287 21 256 255 22.5 0.1 22.9 22.3 07/08/2005 17:40:00 4.5 1.3 7.6 1.9 4.4 1.3 7.6 1.5 3.7 1.3 7.2 1.1 280 21 291 255 23 0.1 23.5 22.9 07/08/2005 17:50:00 4.2 1.2 7.2 1.1 4.1 1.2 7.2 1.1 3.4 1.2 6.8 0.4 286 23 290 255 23 0 23.5 22.9 07/08/2005 18:00:00 3.9 1 6.1 1.5 3.8 1.1 6.1 0.7 3.1 1 5.7 0.4 284 22 312 255 22.9 0 23.2 22.9 07/08/2005 18:10:00 3.8 0.9 5.7 1.1 3.7 1 6.1 0.7 3 1 5.3 0.7 289 20 276 255 23 0 23.5 22.9 07/08/2005 18:20:00 3.7 1.3 6.8 0.7 3.5 1.3 6.8 0.4 3.1 1.3 6.5 0.4 295 17 317 255 23.1 0 23.5 23.2 07/08/2005 18:30:00 3.5 0.9 5.7 1.5 3.5 0.9 5.7 1.9 2.8 0.9 4.9 1.1 279 19 280 255 23.2 0 23.5 23.2 07/08/2005 18:40:00 3.3 1.3 6.8 0.4 3.3 1.3 6.8 0.7 2.5 1.2 6.1 0.4 273 23 275 255 23 0 23.2 22.9 07/08/2005 18:50:00 3.6 1.1 6.8 1.1 3.6 1.1 7.2 1.1 3 1.1 6.8 1.1 282 21 266 255 22.7 0 23.2 22.6 07/08/2005 19:00:00 3.5 1.3 6.8 1.1 3.3 1.3 6.8 0.7 2.6 1.2 6.5 0.4 269 26 262 255 22.4 0.1 23.2 22.3 07/08/2005 19:10:00 3 1.3 6.1 0.4 2.9 1.3 6.1 0.4 2.1 1.2 5.3 0.4 261 26 314 255 22.2 0 22.9 22.3 07/08/2005 19:20:00 3.5 1.3 6.8 0.7 3.4 1.5 6.8 0.4 2.5 1.3 6.5 0.4 265 27 308 255 22.1 0 22.3 22 07/08/2005 19:30:00 3.3 1.2 6.8 0.4 3.2 1.2 7.2 0.7 2.5 1.1 6.1 0.4 266 22 255 255 21.9 0 22.3 21.7 07/08/2005 19:40:00 3.7 1.2 6.8 1.1 3.7 1.2 6.8 0.7 2.9 1.1 6.1 0.4 265 20 253 255 21.7 0.1 22.3 21.4 07/08/2005 19:50:00 3.1 1.3 6.5 1.1 3.1 1.3 6.8 0.7 2.4 1.3 6.1 0.4 267 17 277 255 21.5 0.2 22 21.1 07/08/2005 20:00:00 3.1 1 6.1 1.1 3 1 6.1 0.7 2.3 1 6.5 0.4 266 23 255 255 21.1 0 21.7 20.8 07/08/2005 20:10:00 3.3 1.3 6.1 0.4 3.2 1.4 5.7 0.4 2.6 1.1 5.7 0.4 262 24 264 255 21 0 21.4 20.8 07/08/2005 20:20:00 2.4 0.8 3.8 0.7 2.2 0.9 3.8 0.4 1.7 0.8 4.2 0.4 273 22 239 255 20.7 0.1 21.1 20.5 07/08/2005 20:30:00 2.7 0.9 5.3 0.4 2.6 1 5.3 0.4 1.9 1 3.8 0.4 291 17 288 255 20.3 0.1 21.1 20 07/08/2005 20:40:00 3 1 5.7 0.7 2.9 1.2 5.7 0.4 2.2 1 4.6 0.4 277 21 269 255 19.6 0.1 20.3 19.4 07/08/2005 20:50:00 2.3 0.8 4.6 0.4 2.2 0.9 4.6 0.4 1.6 0.8 3.8 0.4 280 20 260 255 19.4 0 20 19.1 07/08/2005 21:00:00 2.8 1 5.7 0.4 2.7 1 4.9 0.4 1.7 0.9 4.6 0.4 266 22 263 255 19 0 19.4 18.8 07/08/2005 21:10:00 2.4 0.8 4.6 0.7 2.2 0.9 4.2 0.4 1.4 0.8 3.8 0.4 268 19 263 255 18.6 0.1 18.8 18.5 07/08/2005 21:20:00 2.1 0.7 3.8 0.7 1.9 0.8 4.2 0.4 1.3 0.7 3 0.4 284 17 262 255 18.3 0 18.5 18.2 07/08/2005 21:30:00 1.2 0.4 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.3 1.9 0.4 304 22 275 255 17.8 0.1 18.2 17.4 07/08/2005 21:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 9 10 343 255 17.1 0.2 17.4 16.8 07/08/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 0 255 255 16.4 0.1 16.8 16.3 07/08/2005 22:00:00 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.7 0.3 1.5 0.4 92 53 148 255 15.9 0 16.3 15.7 07/08/2005 22:10:00 1.9 0.5 3.4 0.7 1.7 0.6 3.4 0.7 1.6 0.6 3 0.4 149 12 161 255 15.5 0.1 16.3 15.2 07/08/2005 22:20:00 2.8 0.6 4.2 1.5 2.9 0.5 4.2 1.5 2.2 0.6 3.4 0.7 166 8 164 255 15.4 0 16 15.2 07/08/2005 22:30:00 2.5 0.6 3.8 1.1 2.4 0.6 3.8 0.7 1.6 0.6 3 0.4 148 13 136 255 15 0 15.5 14.9 07/08/2005 22:40:00 2.3 0.4 3.4 1.5 2.1 0.4 3.4 1.1 1.5 0.4 2.6 0.4 157 9 141 255 15 0 15.2 14.9 07/08/2005 22:50:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.1 0.4 2.3 0.4 161 7 161 255 14.6 0 15.2 14.4 07/08/2005 23:00:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 151 2 146 255 14.3 0.1 14.9 14.1 07/08/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 152 0 255 255 14.1 0.1 14.6 13.8 07/08/2005 23:20:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 152 0 152 255 13.9 0 14.4 13.5 07/08/2005 23:30:00 1.3 0.6 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 276 66 302 255 13.5 0 13.8 13.3 07/08/2005 23:40:00 2.3 0.3 2.6 1.1 2.1 0.3 2.6 1.5 1.2 0.4 2.3 0.4 286 8 302 255 13.4 0.1 13.8 13 07/08/2005 23:50:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 1.1 0.4 1.9 0.4 294 5 287 255 13.1 0 13.5 13 07/09/2005 00:00:00 1.8 0.4 2.6 0.7 1.5 0.4 2.3 0.7 0.9 0.4 2.3 0.4 294 8 301 255 13.1 0.1 13.3 12.7 07/09/2005 00:10:00 2 0.3 3 0.7 1.8 0.4 2.6 0.4 1 0.5 2.3 0.4 291 5 293 255 12.9 0 13.3 12.7 07/09/2005 00:20:00 1.5 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 317 27 289 255 12.8 0 13.3 12.7 07/09/2005 00:30:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 352 11 341 255 12.7 0 13 12.5 07/09/2005 00:40:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 343 10 320 255 12.7 0 13 12.5 07/09/2005 00:50:00 1.1 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.5 0.4 4 13 345 255 12.6 0 13 12.5 07/09/2005 01:00:00 1 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 2 14 15 255 12.5 0.1 13 12.5 07/09/2005 01:10:00 1 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 38 23 22 255 12.3 0 12.7 12.2 07/09/2005 01:20:00 1.2 0.2 1.9 0.7 0.8 0.3 1.9 0.4 1 0.4 1.9 0.4 70 13 74 255 12 0 12.5 11.9 07/09/2005 01:30:00 1.4 0.3 1.9 0.7 1.1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 91 9 89 255 11.9 0 12.5 11.7 07/09/2005 01:40:00 1.4 0.2 1.9 0.7 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 125 9 108 255 11.9 0 12.5 11.7 07/09/2005 01:50:00 1.6 0.4 2.3 0.7 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 133 10 111 255 11.7 0 12.2 11.7 07/09/2005 02:00:00 2.3 0.4 3.4 1.1 2.2 0.4 3.4 1.1 1.7 0.5 2.6 0.4 138 6 138 255 11.5 0 11.9 11.4 07/09/2005 02:10:00 3.1 0.4 3.8 2.3 3 0.4 3.8 1.9 2.3 0.4 3.4 1.5 136 6 141 255 11.6 0 12.2 11.4 07/09/2005 02:20:00 2.6 0.7 3.8 0.4 2.5 0.8 3.8 0.4 1.8 0.7 3 0.4 131 6 131 255 11.5 0.1 11.9 11.4 07/09/2005 02:30:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.5 0.4 91 17 81 255 11.3 0 11.7 11.1 07/09/2005 02:40:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 95 11 102 255 11.2 0 11.7 11.1 07/09/2005 02:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 102 0 102 255 11.2 0 11.7 11.1 07/09/2005 03:00:00 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 1.1 0.4 1.9 0.4 123 16 144 255 11.1 0 11.4 11.1 07/09/2005 03:10:00 1.3 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 114 0 113 255 10.8 0.1 11.4 10.6 07/09/2005 03:20:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 113 3 113 255 10.6 0 10.9 10.6 07/09/2005 03:30:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 115 15 107 255 10.6 0 10.9 10.6 07/09/2005 03:40:00 1 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 68 17 69 255 10.4 0 10.6 10.3 07/09/2005 03:50:00 1.6 0.2 2.3 1.1 1.4 0.3 1.9 0.4 0.5 0.2 1.5 0.4 99 6 100 255 10.4 0 10.6 10.3 07/09/2005 04:00:00 1.8 0.3 2.6 1.1 1.5 0.3 2.3 0.7 0.6 0.3 1.9 0.4 98 5 100 255 10.5 0 10.6 10.3 07/09/2005 04:10:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 91 3 86 255 10.4 0 10.9 10.3 07/09/2005 04:20:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.2 0.4 2.3 0.4 71 9 77 255 10.5 0 10.6 10.3 07/09/2005 04:30:00 2.3 0.3 3 1.5 2.1 0.3 3 1.5 1.2 0.5 2.3 0.4 80 7 60 255 10.5 0 10.9 10.6 07/09/2005 04:40:00 2.4 0.3 3.4 1.5 2.3 0.4 3 1.1 1.1 0.4 2.3 0.4 86 6 87 255 10.7 0.1 10.9 10.6 07/09/2005 04:50:00 2.3 0.3 3 1.5 2.1 0.3 3 1.1 1.1 0.4 2.3 0.4 90 7 83 255 11.1 0 11.1 10.9 07/09/2005 05:00:00 2.6 0.3 3.4 1.5 2.3 0.4 3 1.1 1.7 0.4 2.6 0.7 103 8 91 255 11.3 0.1 11.7 11.1 07/09/2005 05:10:00 2.3 0.4 3.4 1.1 2 0.4 3 0.4 1.3 0.5 3 0.4 90 7 94 255 12.1 0.2 12.7 11.7 07/09/2005 05:20:00 2.6 0.4 4.2 1.5 2.5 0.4 4.2 1.5 1.5 0.5 2.6 0.4 81 9 79 255 12.5 0.1 12.7 12.2 07/09/2005 05:30:00 1.9 0.5 3 0.7 1.6 0.6 3 0.4 0.9 0.5 2.3 0.4 87 9 84 255 12.8 0.2 13.3 12.5 07/09/2005 05:40:00 1.5 0.6 2.6 0.4 1.3 0.7 3 0.4 0.8 0.5 2.3 0.4 88 13 89 255 13.4 0.1 14.1 13 07/09/2005 05:50:00 1.5 0.4 2.6 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 94 13 87 255 13.9 0.1 14.6 13.5 07/09/2005 06:00:00 1.4 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 102 15 108 255 14.7 0.4 15.7 14.1 07/09/2005 06:10:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 109 17 105 255 15.1 0.1 15.7 14.9 07/09/2005 06:20:00 1.9 0.4 2.6 0.7 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 99 7 100 255 15 0 15.5 14.9 07/09/2005 06:30:00 1.7 0.4 2.6 0.7 1.5 0.5 2.3 0.4 1.2 0.5 2.3 0.4 99 14 90 255 16.1 0.4 17.1 15.5 07/09/2005 06:40:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 77 13 84 255 16.9 0.1 17.4 16.8 07/09/2005 06:50:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.3 0.7 2.6 0.4 76 17 76 255 17.6 0.3 18.2 16.8 07/09/2005 07:00:00 2 0.4 3 1.1 1.8 0.5 3 0.4 1.6 0.5 3 0.4 65 17 74 255 16.6 0.2 17.1 16.3 07/09/2005 07:10:00 1.9 0.4 3 1.1 1.8 0.5 3 0.4 1.6 0.5 3 0.4 55 12 73 255 16.2 0 16.6 16.3 07/09/2005 07:20:00 2.1 0.6 3.4 0.7 1.9 0.7 3.4 0.4 1.7 0.7 3 0.4 40 22 12 255 16.8 0.5 17.7 16.3 07/09/2005 07:30:00 2 0.5 3.4 0.7 1.9 0.5 3 0.4 1.4 0.6 3 0.4 8 14 22 255 18.7 0.3 19.1 17.7 07/09/2005 07:40:00 1.8 0.5 3.4 0.7 1.7 0.6 3 0.4 1.5 0.5 2.6 0.4 48 18 40 255 18.5 0.2 19.1 18.2 07/09/2005 07:50:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.8 0.8 3.4 0.4 44 19 46 255 18.4 0.1 18.8 18.2 07/09/2005 08:00:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1.8 0.5 3.4 0.7 22 13 25 255 18 0 18.2 17.7 07/09/2005 08:10:00 2.2 0.5 3.4 0.7 2 0.6 3.4 0.4 1.6 0.6 3 0.4 13 12 9 255 17.8 0 18 17.4 07/09/2005 08:20:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1.1 0.5 2.6 0.4 9 13 10 255 18.3 0.4 19.4 17.7 07/09/2005 08:30:00 1.9 0.6 3.8 0.4 1.8 0.7 3.8 0.4 1.6 0.7 3.8 0.4 27 18 7 255 20 0.2 20.5 19.4 07/09/2005 08:40:00 2.2 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.9 0.7 3.8 0.4 22 13 31 255 20.1 0 20.5 19.7 07/09/2005 08:50:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.1 0.5 3.4 1.1 26 15 19 255 20.1 0.1 20.8 19.7 07/09/2005 09:00:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 48 21 56 255 20.9 0.2 21.7 20.5 07/09/2005 09:10:00 1.9 0.5 3 0.4 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 45 16 75 255 20.8 0.2 21.1 20.3 07/09/2005 09:20:00 1.9 0.5 3.4 0.7 1.8 0.6 3.4 0.4 1.8 0.6 3 0.4 48 17 40 255 20.5 0 20.8 20.3 07/09/2005 09:30:00 2 0.6 3.4 0.4 1.9 0.6 3.8 0.4 1.7 0.6 3.4 0.4 50 15 61 255 20 0 20.5 20 07/09/2005 09:40:00 1.4 0.5 3 0.4 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 62 16 71 255 19.7 0.2 20 19.4 07/09/2005 09:50:00 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 0.9 0.5 2.6 0.4 52 21 73 255 19.5 0 20 19.4 07/09/2005 10:00:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 85 12 86 255 19.7 0.2 20.5 19.4 07/09/2005 10:10:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 68 12 91 255 20.3 0 20.8 20 07/09/2005 10:20:00 1.2 0.4 2.3 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 51 19 36 255 20.3 0.1 20.8 20 07/09/2005 10:30:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.5 2.6 0.4 52 18 55 255 20.1 0 20.5 20 07/09/2005 10:40:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 10 26 332 255 20.1 0 20.5 20 07/09/2005 10:50:00 1.3 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 30 17 51 255 20.6 0.3 21.4 20.3 07/09/2005 11:00:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 49 33 31 255 22 0.2 22.6 21.4 07/09/2005 11:10:00 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 66 33 42 255 22.7 0 23.2 22.6 07/09/2005 11:20:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 80 33 105 255 23 0.1 23.5 22.6 07/09/2005 11:30:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 27 66 57 255 23.6 0 24.4 23.5 07/09/2005 11:40:00 1.4 0.7 3 0.4 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 31 27 34 255 23.8 0.1 24.4 23.5 07/09/2005 11:50:00 1.5 0.8 3 0.4 1.5 0.8 3 0.4 1.4 0.9 3.8 0.4 356 35 9 255 24.4 0 24.7 24.1 07/09/2005 12:00:00 1.7 0.7 3.8 0.4 1.5 0.8 3.8 0.4 1.3 0.7 3 0.4 27 51 14 255 25 0.2 25.3 24.7 07/09/2005 12:10:00 1.8 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.8 0.5 3.4 1.1 24 29 342 255 24.9 0 25 24.7 07/09/2005 12:20:00 1.3 0.6 3 0.4 1.2 0.6 3.4 0.4 1.1 0.6 3 0.4 46 58 44 255 24.5 0 25 24.1 07/09/2005 12:30:00 2 0.7 3.8 0.4 1.8 0.8 3.4 0.4 1.7 0.7 3.4 0.4 320 30 300 255 24.9 0 25.3 24.7 07/09/2005 12:40:00 2 1.2 4.9 0.4 1.9 1.2 4.9 0.4 1.6 1 4.2 0.4 337 47 20 255 25.1 0 25.6 25 07/09/2005 12:50:00 1.7 0.7 3 0.4 1.6 0.7 3 0.4 1.5 0.7 3.4 0.4 288 53 290 255 25.5 0 25.9 25.3 07/09/2005 13:00:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.9 0.7 3.4 0.4 292 45 251 255 25.9 0.1 26.2 25.6 07/09/2005 13:10:00 2.5 0.8 4.9 0.4 2.4 0.9 4.9 0.4 2.2 1 4.6 0.4 278 29 252 255 26 0 26.2 25.6 07/09/2005 13:20:00 2.2 0.8 4.2 0.4 2.1 0.9 4.6 0.4 1.7 0.9 4.2 0.4 280 38 261 255 26.1 0.2 26.5 25.6 07/09/2005 13:30:00 2.1 0.8 4.6 0.4 2 0.9 4.6 0.4 1.8 0.9 3.8 0.4 299 45 266 255 26.1 0 26.5 26.2 07/09/2005 13:40:00 2.8 0.9 5.3 1.1 2.7 0.9 4.9 0.7 2.1 1 4.6 0.4 302 33 283 255 26.5 0 26.5 26.2 07/09/2005 13:50:00 3.1 0.9 5.3 0.7 2.9 0.9 5.3 0.4 2.6 0.9 5.3 1.1 301 21 305 255 26.1 0.1 26.5 25.9 07/09/2005 14:00:00 2.9 0.9 4.9 0.7 2.7 1 5.3 0.4 2.3 1 4.9 0.4 338 21 300 255 26.4 0.2 27.1 26.2 07/09/2005 14:10:00 2.9 0.7 5.3 1.5 2.6 0.6 5.3 1.1 2.2 0.8 4.2 0.7 344 21 340 255 27.1 0 27.1 26.8 07/09/2005 14:20:00 2.9 0.9 5.3 1.1 2.7 0.9 5.3 0.7 2.4 0.8 5.3 0.7 323 20 311 255 26.9 0 27.1 26.8 07/09/2005 14:30:00 3.1 1 6.1 1.1 3 1 6.1 1.1 2.5 1 4.9 0.4 297 30 310 255 26.8 0 27.1 26.5 07/09/2005 14:40:00 2.2 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.7 0.9 4.2 0.4 291 43 297 255 27.2 0.3 27.7 26.5 07/09/2005 14:50:00 1.6 0.8 3.8 0.4 1.5 1 3.8 0.4 1.4 0.8 3.4 0.4 262 49 222 255 27 0 27.4 26.8 07/09/2005 15:00:00 2.5 0.8 4.2 0.4 2.4 0.9 4.2 0.4 2.1 1.1 4.9 0.4 273 32 282 255 26.9 0 27.4 26.5 07/09/2005 15:10:00 1.9 0.9 3.8 0.4 1.7 1 3.8 0.4 1.7 0.9 3.8 0.4 252 41 255 255 26.8 0 27.1 26.5 07/09/2005 15:20:00 2.5 0.9 4.6 0.4 2.2 1 4.6 0.4 1.8 1 4.9 0.4 320 39 317 255 27.3 0.2 27.7 26.8 07/09/2005 15:30:00 2 0.6 3.8 0.7 1.9 0.6 3.4 0.4 1.6 0.7 3 0.4 332 27 314 255 27.1 0.2 27.7 26.8 07/09/2005 15:40:00 2.5 1.2 5.3 0.4 2.4 1.2 5.3 0.4 2.2 1.1 4.9 0.4 301 49 351 255 27.6 0 27.7 27.4 07/09/2005 15:50:00 2.4 0.7 4.2 0.4 2.1 0.8 4.2 0.4 2.2 0.7 4.2 0.7 323 23 300 255 27.6 0 28 27.4 07/09/2005 16:00:00 2.1 0.7 3.8 0.4 1.9 0.7 4.2 0.4 1.6 0.7 3.4 0.4 338 22 355 255 27.4 0 27.7 27.4 07/09/2005 16:10:00 2.5 0.7 3.8 0.7 2.3 0.8 3.8 0.7 2 0.8 3.8 0.4 300 39 350 255 27.5 0 27.7 27.4 07/09/2005 16:20:00 0.9 0.6 3.4 0.4 0.7 0.6 2.6 0.4 0.6 0.5 3 0.4 220 72 297 255 27.2 0 27.4 27.1 07/09/2005 16:30:00 2.1 1 4.6 0.4 1.8 1 4.9 0.4 1.6 1.1 4.2 0.4 317 29 313 255 27.4 0 27.7 27.1 07/09/2005 16:40:00 2.6 1 5.3 0.4 2.4 1.1 4.9 0.4 2.2 1.1 4.6 0.4 312 19 333 255 27.3 0 27.4 26.8 07/09/2005 16:50:00 2.2 1 4.9 0.4 2 1 4.9 0.4 1.6 0.8 4.6 0.4 310 33 295 255 26.9 0 27.1 26.8 07/09/2005 17:00:00 2.7 1 5.3 0.4 2.6 1.1 5.7 0.4 2.1 1.2 5.7 0.4 306 33 359 255 27.2 0 27.4 27.1 07/09/2005 17:10:00 2.8 1 5.3 0.4 2.7 1 5.7 0.7 2.3 1 4.9 0.4 299 26 290 255 26.9 0 27.1 26.5 07/09/2005 17:20:00 3.2 0.8 5.7 1.1 3 0.9 5.7 0.7 2.5 0.9 4.6 0.4 295 22 285 255 26.4 0 26.8 26.2 07/09/2005 17:30:00 2.4 1 4.9 0.4 2.3 1.1 4.9 0.4 1.8 1.1 4.9 0.4 284 45 319 255 26.1 0 26.5 26.2 07/09/2005 17:40:00 2 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.6 1 4.2 0.4 301 26 289 255 26.3 0 26.5 26.2 07/09/2005 17:50:00 2.2 0.8 4.2 0.4 2.1 0.9 4.2 0.4 1.7 0.8 3.4 0.4 285 30 291 255 26 0 26.2 25.9 07/09/2005 18:00:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 1.2 0.6 2.3 0.4 313 58 312 255 26 0 26.2 25.6 07/09/2005 18:10:00 1.7 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1.3 0.8 3.4 0.4 107 49 113 255 25.4 0.4 25.9 24.7 07/09/2005 18:20:00 3 1.2 6.8 1.1 2.9 1.2 6.5 0.7 2.8 1.1 6.1 1.1 122 28 148 255 23.8 0.6 25 22.9 07/09/2005 18:30:00 3.4 1 6.5 0.7 3.6 1.2 6.5 0.4 2.8 1.3 6.1 0.4 181 28 193 255 22.1 0.2 22.9 21.7 07/09/2005 18:40:00 4.2 1.2 8 1.1 4.3 1.3 7.6 0.7 3.5 1 6.5 1.1 143 24 157 255 21.8 0.2 22.3 21.4 07/09/2005 18:50:00 3.4 1 6.8 1.1 3.3 1.1 6.1 0.7 3 1 5.3 0.4 139 22 160 255 21.3 0 21.4 21.1 07/09/2005 19:00:00 3.5 0.9 6.5 1.9 3.5 0.9 6.1 1.1 2.7 0.9 5.3 0.4 126 26 129 255 20.8 0.2 21.1 20.5 07/09/2005 19:10:00 3.9 1.2 6.8 1.1 3.8 1.3 6.8 0.7 3.2 1.3 6.8 1.1 107 20 96 255 20.4 0 20.5 20.3 07/09/2005 19:20:00 4.2 1 6.5 1.9 4.2 1 6.8 1.5 3.4 1 5.3 0.7 97 15 110 255 20.1 0 20.5 20 07/09/2005 19:30:00 3.4 1 6.1 0.7 3.3 1 6.1 0.7 2.9 1 5.3 0.4 98 17 113 255 20 0.1 20.5 19.7 07/09/2005 19:40:00 3.5 1 6.5 1.5 3.5 1 6.1 1.1 2.8 1 5.3 0.7 101 15 86 255 19.7 0.2 20.3 19.4 07/09/2005 19:50:00 1.8 0.9 3.8 0.4 1.7 1 3.8 0.4 1.3 0.7 3.4 0.4 80 28 108 255 19.6 0.2 20.3 19.4 07/09/2005 20:00:00 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 74 26 93 255 19.7 0 20.3 19.4 07/09/2005 20:10:00 2.2 0.7 3.8 0.4 2.1 0.8 3.4 0.4 1.7 0.8 3.4 0.4 52 20 43 255 19.5 0.1 20 19.4 07/09/2005 20:20:00 2.7 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2.1 0.5 3.4 0.7 95 26 114 255 19.2 0.1 20 18.8 07/09/2005 20:30:00 2.3 1 4.9 0.4 2.2 1 4.9 0.4 1.9 1 4.6 0.4 91 27 108 255 18.7 0 19.1 18.5 07/09/2005 20:40:00 2.3 0.5 3.8 1.1 2.1 0.6 3.8 0.7 1.8 0.6 3.4 0.4 102 23 102 255 18.5 0.1 19.1 18.2 07/09/2005 20:50:00 1.9 1.1 5.3 0.4 1.6 1.1 4.6 0.4 1.4 1 3.8 0.4 72 30 47 255 18.2 0 18.8 18 07/09/2005 21:00:00 3.9 0.8 5.7 2.3 3.8 0.9 5.7 1.9 3.2 0.9 5.3 1.5 33 13 6 255 18.4 0.1 19.1 18.2 07/09/2005 21:10:00 4.7 1 6.8 2.6 4.7 1 6.8 2.3 3.8 1 6.5 1.5 46 13 17 255 18.8 0 19.4 18.5 07/09/2005 21:20:00 4.9 1 7.6 2.6 4.9 1.1 8.4 2.3 4.1 1.1 7.2 1.5 54 17 63 255 18.7 0 19.1 18.5 07/09/2005 21:30:00 4.9 1 7.6 2.3 5 1 7.6 1.9 3.8 1 6.8 0.7 54 17 47 255 18.4 0 18.5 18.2 07/09/2005 21:40:00 5.1 1.1 8 3 5.1 1.1 8.4 2.6 4.1 1 6.8 1.9 49 13 58 255 18.2 0 18.2 18 07/09/2005 21:50:00 5.6 1 8.4 3.4 5.5 1.1 9.1 2.6 4.5 1 7.2 1.9 55 15 46 255 18.2 0 18.2 18 07/09/2005 22:00:00 5.1 1.3 8.8 1.9 5.2 1.3 8.8 2.6 4.1 1.3 8 1.1 60 17 34 255 18.2 0 18.2 18 07/09/2005 22:10:00 4.2 1 6.8 1.5 4.2 1 6.8 1.9 3.5 1.1 6.5 1.1 69 17 49 255 18.1 0 18.2 18 07/09/2005 22:20:00 3.4 0.8 6.5 1.9 3.4 0.8 6.5 1.5 2.8 0.8 5.3 0.4 82 17 68 255 18 0 18.2 17.7 07/09/2005 22:30:00 3.1 1 5.7 0.7 2.9 1 5.7 0.4 2.4 1 4.9 0.4 80 26 106 255 17.8 0 18 17.4 07/09/2005 22:40:00 2.9 0.9 5.7 0.4 2.7 1 6.1 0.4 2.5 0.9 5.7 1.1 86 19 93 255 17.5 0 17.7 17.4 07/09/2005 22:50:00 3.4 0.7 5.3 1.1 3.3 0.8 5.3 1.5 2.7 0.9 4.9 0.4 81 17 79 255 17.3 0 17.4 17.1 07/09/2005 23:00:00 3.3 0.8 5.3 1.9 3.2 0.9 5.3 1.1 2.6 0.7 4.6 0.7 66 17 69 255 17.3 0 17.7 17.1 07/09/2005 23:10:00 4.2 0.8 6.5 2.3 4.2 0.8 6.8 2.3 3.3 0.9 5.7 1.1 70 15 68 255 17.2 0 17.4 16.8 07/09/2005 23:20:00 4.2 0.9 6.5 1.9 4.3 0.9 6.5 1.9 3.2 1.1 6.1 1.1 77 17 68 255 17 0 17.1 16.8 07/09/2005 23:30:00 4.1 0.8 6.1 1.9 4 0.9 6.5 1.5 3.1 0.9 5.7 0.7 71 17 62 255 17 0 17.4 16.8 07/09/2005 23:40:00 3.4 1.1 6.1 0.7 3.3 1.2 6.1 0.4 2.9 1 6.1 0.7 69 15 53 255 17.2 0 17.7 16.8 07/09/2005 23:50:00 4.1 0.9 6.5 2.3 4 0.9 6.5 1.5 3.1 0.8 5.3 0.7 78 16 96 255 17.3 0.1 17.7 17.1 07/10/2005 00:00:00 4.1 1 6.5 1.9 4.1 1 6.5 1.5 3.1 1.1 6.1 0.4 77 17 79 255 17.5 0 17.7 17.4 07/10/2005 00:10:00 3.3 0.8 5.3 0.7 3.2 0.9 5.3 0.7 2.4 1 4.6 0.4 70 19 66 255 17.5 0 17.7 17.4 07/10/2005 00:20:00 4.7 0.9 6.8 2.6 4.7 1 7.2 1.9 3.7 1 6.5 1.1 73 15 64 255 17.8 0 18.2 17.4 07/10/2005 00:30:00 3.6 0.8 5.7 1.5 3.5 0.8 5.7 1.5 2.7 0.8 4.6 0.4 86 15 94 255 17.4 0.1 18 17.1 07/10/2005 00:40:00 3.5 0.9 5.7 1.5 3.4 1 6.1 1.1 2.6 0.9 4.9 0.7 80 15 89 255 16.9 0.1 17.4 16.6 07/10/2005 00:50:00 3.5 0.7 5.3 1.9 3.5 0.7 5.3 1.9 2.7 0.7 4.2 1.1 75 12 79 255 16.8 0 17.1 16.6 07/10/2005 01:00:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 1.9 2.8 0.7 4.2 1.1 88 15 104 255 16.6 0.1 16.8 16.3 07/10/2005 01:10:00 3.9 0.9 6.1 1.9 3.9 0.9 6.1 1.5 3.1 0.8 5.7 1.1 58 17 48 255 16.3 0 16.8 16.3 07/10/2005 01:20:00 3.9 0.8 7.2 1.9 3.8 0.9 7.2 1.5 3.3 0.8 6.1 1.5 60 17 69 255 16.4 0 16.8 16.3 07/10/2005 01:30:00 3.3 1 5.7 1.5 3.3 1.1 5.7 0.7 2.8 1 6.1 1.1 61 15 66 255 16.4 0.1 16.8 16.3 07/10/2005 01:40:00 3.3 1 6.5 1.5 3.2 1 6.8 1.5 2.4 0.8 5.3 0.4 70 22 70 255 16.1 0 16.6 15.7 07/10/2005 01:50:00 3.4 0.8 7.6 1.9 3.2 0.8 6.8 1.5 2.5 0.7 4.6 0.7 94 17 55 255 15.4 0.3 16 15.2 07/10/2005 02:00:00 2.9 0.9 5.3 0.7 2.7 0.9 5.3 0.4 2.1 0.9 4.9 0.4 90 24 91 255 15.1 0.1 15.7 15.2 07/10/2005 02:10:00 2.5 0.6 4.2 0.7 2.3 0.6 3.8 0.7 1.8 0.6 3.4 0.4 92 19 102 255 15.5 0 16 15.2 07/10/2005 02:20:00 2.2 0.6 3.8 0.7 2 0.7 3.4 0.4 1.6 0.6 3.4 0.4 92 20 86 255 15.7 0 16.3 15.5 07/10/2005 02:30:00 3 0.8 5.3 0.4 2.8 0.9 5.3 0.4 2.1 0.8 4.6 0.4 75 18 56 255 15.6 0 16.3 15.7 07/10/2005 02:40:00 3.4 0.8 5.7 1.5 3.2 0.9 5.7 0.4 2.6 0.9 4.9 0.7 70 21 81 255 15.8 0 16.3 15.7 07/10/2005 02:50:00 3.8 0.9 6.1 2.3 3.8 1 6.1 1.9 3.1 1 5.3 1.1 72 15 74 255 16.1 0 16.8 16 07/10/2005 03:00:00 3.7 0.8 5.7 1.5 3.6 0.9 6.1 1.1 2.8 0.9 5.3 0.4 71 17 32 255 16.1 0 16.8 16 07/10/2005 03:10:00 4.1 0.8 6.1 2.3 4.1 0.9 6.1 1.9 3.4 0.9 5.3 1.5 77 15 68 255 16.1 0 16.8 16 07/10/2005 03:20:00 4.4 1 6.8 1.9 4.3 1 6.5 1.9 3.4 1 6.1 1.5 76 16 136 255 16.1 0 16.8 16.3 07/10/2005 03:30:00 4.2 1 6.8 2.3 4.2 1 6.8 1.9 3.4 1 6.1 1.5 69 15 64 255 16.3 0.1 16.8 16.3 07/10/2005 03:40:00 4.1 0.9 6.8 1.9 4 1 6.5 1.5 3.1 0.8 5.3 1.1 71 17 81 255 16.3 0 16.8 16.3 07/10/2005 03:50:00 4.1 1 7.2 1.1 4 1 7.2 1.5 3.2 1 6.1 0.7 65 19 58 255 16.2 0 16.8 16.3 07/10/2005 04:00:00 4.4 1 7.2 2.3 4.4 1 7.2 1.9 3.6 1 6.5 0.4 64 18 72 255 16.3 0.1 16.8 16.3 07/10/2005 04:10:00 4.5 1.3 7.6 1.9 4.5 1.4 7.6 1.5 3.6 1.3 6.8 0.7 67 16 60 255 16.3 0 16.8 16 07/10/2005 04:20:00 4.1 0.9 6.8 2.3 4 0.9 6.8 2.3 3.1 1 5.7 0.4 75 16 69 255 15.9 0 16.6 15.7 07/10/2005 04:30:00 4.6 1 7.6 1.5 4.6 1 8 1.5 3.7 1.1 7.6 1.1 70 14 72 255 16 0.1 16.6 15.7 07/10/2005 04:40:00 4.2 1 6.5 1.9 4.1 1.1 6.5 1.1 3.2 1.1 6.5 1.5 69 17 50 255 16.1 0.1 16.6 16 07/10/2005 04:50:00 4.1 0.8 6.1 1.9 4.1 0.9 6.5 1.9 3.5 0.9 5.7 0.7 71 15 66 255 16 0.1 16.6 15.7 07/10/2005 05:00:00 3.5 0.8 5.3 1.1 3.3 0.8 5.3 1.1 2.6 0.8 4.9 0.7 85 16 91 255 16 0 16.6 15.7 07/10/2005 05:10:00 3.8 0.9 6.5 1.5 3.7 0.9 6.5 1.1 2.6 0.9 5.7 0.7 74 21 78 255 16.2 0.1 16.8 16 07/10/2005 05:20:00 4.2 0.8 6.1 1.9 4.1 0.9 6.5 2.3 3.2 1 6.1 0.7 70 20 73 255 16.4 0.2 17.1 16.3 07/10/2005 05:30:00 3.8 0.9 6.1 1.1 3.8 1 6.1 0.4 3.1 1 5.7 0.4 69 20 73 255 17 0.1 17.4 16.6 07/10/2005 05:40:00 3.6 0.8 6.1 1.9 3.5 0.8 5.7 1.9 2.9 0.9 5.7 0.7 78 20 79 255 17.3 0.1 17.7 16.8 07/10/2005 05:50:00 3.9 1 6.1 1.9 3.7 1.1 6.1 1.5 3.2 1.1 6.1 0.7 67 22 103 255 17.8 0 18.2 17.4 07/10/2005 06:00:00 3.9 1 6.5 1.1 3.8 1.1 6.1 0.7 3.1 1 5.3 0.7 58 21 48 255 18.3 0.2 18.8 17.7 07/10/2005 06:10:00 4.2 1 6.5 1.9 4.2 1 6.5 2.3 3.4 1.2 5.7 0.7 72 18 68 255 18.5 0.2 19.1 18.2 07/10/2005 06:20:00 4.1 0.8 6.1 2.3 4 0.9 6.1 1.9 3.4 0.8 5.3 1.1 69 18 42 255 18.2 0 18.5 18 07/10/2005 06:30:00 4.3 0.9 6.5 2.3 4.2 1 7.2 1.9 3.5 0.8 5.7 1.9 64 17 89 255 18.5 0.2 18.8 18 07/10/2005 06:40:00 3.9 0.8 5.7 1.9 3.8 0.9 5.7 1.5 3 1 5.7 0.7 65 17 49 255 19 0 19.4 18.8 07/10/2005 06:50:00 3.7 1 6.1 1.1 3.7 1 6.1 1.1 3.1 1 5.3 0.4 60 17 66 255 18.9 0.1 19.1 18.5 07/10/2005 07:00:00 4.1 1.2 6.8 1.1 4 1.2 6.8 0.7 3.5 1.4 6.1 0.4 69 20 68 255 18.7 0 18.8 18.5 07/10/2005 07:10:00 4.3 0.9 6.8 2.6 4.2 0.9 6.8 2.3 3.7 1 6.5 1.5 62 17 60 255 18.3 0 18.8 18 07/10/2005 07:20:00 4.6 1.1 7.6 1.9 4.6 1.2 7.6 1.1 3.8 1.2 6.8 1.1 57 18 59 255 19.1 0.2 19.4 18.5 07/10/2005 07:30:00 4.7 0.9 7.2 2.3 4.7 0.9 6.8 2.3 3.8 0.9 6.1 1.9 48 14 52 255 19.7 0.1 20.3 19.4 07/10/2005 07:40:00 3.9 1 6.8 1.1 3.9 1 6.1 0.7 3.2 1.1 6.1 0.4 51 18 75 255 20.4 0.2 21.1 20 07/10/2005 07:50:00 4.5 1.1 8 1.5 4.5 1.1 8.4 0.7 3.8 1.2 6.8 1.1 42 17 26 255 20.5 0 21.1 20.5 07/10/2005 08:00:00 5.4 1 8.8 3 5.3 1 8.4 3 4.6 1 8 1.9 39 14 23 255 20.6 0 21.1 20.5 07/10/2005 08:10:00 4.7 1.2 8.4 2.3 4.7 1.2 8 1.9 4 1.1 7.2 1.5 40 16 40 255 20.6 0.1 21.1 20.5 07/10/2005 08:20:00 5 1.1 8.8 2.3 5 1.1 8.4 2.3 4.2 1.2 8 1.9 47 17 69 255 20.8 0.2 21.4 20.5 07/10/2005 08:30:00 4.4 1 6.8 2.3 4.3 1 6.8 1.5 3.7 1.1 6.5 1.1 42 17 32 255 21.3 0.1 21.7 21.1 07/10/2005 08:40:00 4.9 1.5 8.4 1.5 4.9 1.5 8.4 1.5 4 1.5 7.2 0.7 26 20 49 255 21.9 0.1 22.6 21.4 07/10/2005 08:50:00 5 1.6 9.1 1.1 4.9 1.6 9.1 1.1 4 1.6 8.8 0.4 27 22 58 255 22.7 0 22.9 22.3 07/10/2005 09:00:00 6.4 1.7 10.3 2.3 6.4 1.8 10.3 2.3 5.5 1.6 9.5 2.3 44 17 31 255 22.3 0 22.9 22 07/10/2005 09:10:00 5.7 1.2 9.5 2.6 5.7 1.2 8.8 3 4.6 1.3 8.8 1.5 51 18 25 255 22.2 0 22.6 22 07/10/2005 09:20:00 4.4 0.9 8.4 2.3 4.4 1 8.4 2.3 3.9 1 7.2 1.1 44 17 52 255 21.7 0.1 22 21.4 07/10/2005 09:30:00 4.3 1.7 9.5 1.9 4.2 1.8 9.5 1.5 3.3 1.7 7.6 0.4 19 27 9 255 23.1 0.5 23.8 22 07/10/2005 09:40:00 5.3 1 8.4 2.6 5.2 1 7.6 1.9 4.4 1.1 8 0.7 30 18 1 255 23.7 0 23.8 23.5 07/10/2005 09:50:00 5.5 0.9 8.8 2.6 5.5 1 9.1 3 4.3 1.1 6.5 0.7 17 18 15 255 24 0.3 25 23.5 07/10/2005 10:00:00 4.5 1.2 7.6 1.1 4.4 1.3 8 1.1 3.3 1.2 6.5 0.4 5 20 9 255 25 0.2 25.3 24.4 07/10/2005 10:10:00 3.2 1.3 5.7 0.7 3.1 1.4 5.7 0.4 2.6 1.4 5.7 0.4 17 22 12 255 24.7 0.1 25.3 24.4 07/10/2005 10:20:00 2.5 1.1 4.9 0.4 2.4 1.1 4.9 0.4 2 1 4.2 0.4 18 12 9 255 24.7 0.2 25 24.1 07/10/2005 10:30:00 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 21 38 342 255 24.7 0 25.3 24.1 07/10/2005 10:40:00 1.2 0.5 2.6 0.4 0.9 0.5 2.6 0.4 1 0.6 2.6 0.4 9 38 18 255 24.4 0.2 25 24.1 07/10/2005 10:50:00 1.7 1 4.2 0.4 1.5 1.1 4.2 0.4 1.2 0.9 3.8 0.4 23 28 22 255 24.3 0 24.7 23.8 07/10/2005 11:00:00 3.6 0.8 6.1 1.9 3.6 0.8 6.1 1.9 3 0.8 4.9 1.5 22 13 16 255 25.2 0.4 26.2 24.4 07/10/2005 11:10:00 4.8 0.6 6.5 3 4.8 0.6 6.5 3 4 0.8 6.1 1.5 16 10 35 255 26.1 0 26.5 25.9 07/10/2005 11:20:00 3.1 1 5.3 0.4 3 1 5.3 0.4 2.6 1 4.6 0.4 13 23 358 255 25.7 0.1 26.2 25.6 07/10/2005 11:30:00 3.4 0.7 5.3 0.7 3.4 0.8 5.3 0.4 2.8 0.9 5.7 0.7 27 20 38 255 26.3 0 26.5 25.9 07/10/2005 11:40:00 3.5 0.7 5.3 1.9 3.5 0.7 5.7 1.9 3.2 0.8 5.3 1.5 52 19 52 255 25.7 0.2 26.5 25.3 07/10/2005 11:50:00 4.4 1 6.8 1.5 4.3 1 6.5 1.1 3.4 1.3 6.1 0.7 15 15 15 255 25 0 25.3 24.7 07/10/2005 12:00:00 3.7 1.1 6.1 1.1 3.7 1.1 6.1 1.1 3.2 1.2 6.1 0.7 22 12 19 255 24.2 0 25 24.1 07/10/2005 12:10:00 3.9 0.9 6.1 1.5 3.8 1 6.5 1.1 3.3 1.1 5.7 0.4 31 14 20 255 24.1 0 24.4 23.8 07/10/2005 12:20:00 3.8 0.8 5.7 1.9 3.7 0.8 5.3 2.3 3.1 0.9 5.3 1.5 28 17 18 255 24.7 0.1 25.3 24.4 07/10/2005 12:30:00 3.5 0.7 5.7 1.9 3.5 0.8 6.1 1.5 2.7 0.9 4.6 0.4 30 26 1 255 24.7 0.2 25.6 24.4 07/10/2005 12:40:00 4.8 0.9 6.8 1.9 4.8 1 6.8 1.9 3.9 1 6.1 1.1 12 11 2 255 26.5 0.5 27.1 25.6 07/10/2005 12:50:00 4 1 6.5 1.9 3.9 1.1 6.5 1.5 3 1 6.1 1.1 15 19 359 255 27 0 27.1 26.8 07/10/2005 13:00:00 5.1 0.8 7.6 3 5.1 0.8 7.6 3 4.5 1 6.8 1.9 34 16 11 255 26.6 0.3 27.1 26.2 07/10/2005 13:10:00 5.3 1.8 8.4 1.1 5.3 1.8 8.4 0.7 4.4 2.1 8.4 0.4 27 17 28 255 26.5 0 27.1 26.2 07/10/2005 13:20:00 5.3 1.1 8 1.9 5.3 1.2 8.4 2.3 4.3 1.1 6.8 1.5 43 18 51 255 26.9 0 27.1 26.5 07/10/2005 13:30:00 5.7 1.1 8 3 5.6 1.1 8 3 4.6 1.2 8.4 1.9 32 15 37 255 26 0.4 26.5 25.3 07/10/2005 13:40:00 6.4 1.3 9.9 3 6.4 1.3 9.5 3 5.1 1.3 8.4 1.9 27 16 44 255 26.3 0.3 26.8 25.3 07/10/2005 13:50:00 6.9 1.2 9.9 3.4 6.9 1.2 9.9 3.8 5.7 1.2 9.5 2.6 29 15 21 255 24.8 0.3 25.6 24.1 07/10/2005 14:00:00 7.4 1.2 9.9 3.4 7.4 1.2 9.9 3.4 6.4 1.3 9.5 3 25 10 21 255 24.1 0.3 25 23.8 07/10/2005 14:10:00 7 1.7 11.5 3.4 7 1.7 11.5 3 5.9 1.7 11.1 1.5 27 15 25 255 25.6 0.3 26.2 25 07/10/2005 14:20:00 7.1 1.3 10.7 3.8 7.1 1.3 10.3 3.8 5.4 1.6 9.5 1.9 27 16 32 255 26 0 26.2 25.9 07/10/2005 14:30:00 7 1.5 11.1 3.4 6.9 1.5 10.7 3.8 5.9 1.6 9.5 2.3 23 14 19 255 25.9 0 26.2 25.9 07/10/2005 14:40:00 7 2 12.6 3 7 2.1 12.6 3 5.6 2.1 9.9 1.1 25 22 12 255 25.8 0 26.2 25.6 07/10/2005 14:50:00 7.7 1.4 11.1 4.2 7.6 1.5 10.7 3.8 6.4 1.6 10.3 2.6 28 17 35 255 25.8 0.1 26.2 25.6 07/10/2005 15:00:00 6.6 1.5 10.7 1.9 6.4 1.6 11.1 1.9 4.9 1.6 9.5 0.7 25 18 27 255 26 0.1 26.2 25.6 07/10/2005 15:10:00 7.1 1.4 10.3 3.4 7 1.3 10.7 3 5.9 1.5 9.9 2.6 26 12 13 255 25.4 0 25.9 25.3 07/10/2005 15:20:00 8 1.5 11.8 3.4 8 1.5 11.5 3.4 6.5 1.7 10.7 2.3 24 19 40 255 24.5 0.3 25.3 24.1 07/10/2005 15:30:00 8.9 1.5 12.6 5.3 8.9 1.5 12.6 5.3 7.5 1.7 11.5 3.4 25 15 24 255 24.9 0 25 24.7 07/10/2005 15:40:00 7.1 1.5 10.3 3.8 7 1.5 10.7 3.8 5.7 1.7 9.9 1.9 24 14 28 255 24.5 0.1 25 24.1 07/10/2005 15:50:00 6.7 1.5 9.9 2.6 6.7 1.5 9.9 1.9 5.4 1.5 8.8 1.9 21 17 15 255 25.3 0.4 26.2 24.4 07/10/2005 16:00:00 6.4 1.3 9.9 3 6.4 1.3 10.3 3 5.6 1.4 9.9 2.6 23 12 28 255 26 0 26.2 25.9 07/10/2005 16:10:00 7 1.5 10.7 3 7 1.5 10.7 2.6 5.8 1.3 8.8 2.3 32 16 64 255 25.2 0.6 25.9 23.8 07/10/2005 16:20:00 6.4 1.6 11.5 2.6 6.3 1.6 11.8 3 5 1.7 10.7 0.7 23 17 17 255 23.9 0 24.1 23.8 07/10/2005 16:30:00 7.5 1.5 11.1 4.2 7.5 1.5 11.5 3.4 6 1.6 9.9 2.6 15 13 12 255 23.8 0 24.1 23.5 07/10/2005 16:40:00 8 1.2 11.8 3.8 7.9 1.3 12.2 3.8 6 1.6 11.5 2.6 16 12 14 255 24.3 0.1 24.7 23.8 07/10/2005 16:50:00 5.4 1.3 8.8 1.9 5.4 1.3 9.1 2.3 3.7 1.4 8.8 0.7 8 17 34 255 23.3 0.4 24.4 22.9 07/10/2005 17:00:00 6.2 1.2 9.9 2.6 6.2 1.3 9.9 2.3 4.2 1.3 7.6 1.5 10 15 9 255 22.4 0.1 22.9 22.3 07/10/2005 17:10:00 3.8 2.1 7.6 0.4 3.6 2.2 7.6 0.4 2.5 1.5 6.8 0.4 356 26 355 255 22.4 0.1 23.2 22.3 07/10/2005 17:20:00 5.6 1 8 3 5.5 1 8 3.4 4.2 1.2 7.6 2.3 17 10 23 255 22.7 0 22.9 22.9 07/10/2005 17:30:00 4.1 1.5 7.6 0.4 4 1.5 7.6 0.4 3.2 1.5 6.8 0.4 13 35 50 255 23.3 0 23.5 22.9 07/10/2005 17:40:00 3.7 1.1 6.1 0.7 3.6 1.2 6.5 0.4 2.9 1.2 5.7 0.4 264 24 273 255 22.9 0.2 23.5 22.6 07/10/2005 17:50:00 2.8 1.3 5.7 0.4 2.6 1.3 6.1 0.4 2.1 1.1 4.9 0.4 256 29 257 255 22.2 0 22.9 22 07/10/2005 18:00:00 1.7 1.2 5.7 0.4 1.5 1.2 6.1 0.4 1.3 1.1 6.1 0.4 265 32 259 255 22 0 22.3 22 07/10/2005 18:10:00 2.6 1.1 5.7 0.4 2.4 1.1 5.3 0.4 2.1 0.9 4.9 0.4 255 22 264 255 21.9 0 22 21.7 07/10/2005 18:20:00 2.8 1.4 5.7 0.4 2.7 1.4 5.3 0.4 2.3 1.1 4.9 0.4 261 24 274 255 21.6 0 22 21.4 07/10/2005 18:30:00 2.5 0.8 4.6 0.7 2.4 0.8 4.6 0.4 1.9 0.9 4.2 0.4 253 26 261 255 21.6 0 22 21.4 07/10/2005 18:40:00 2.7 0.8 4.9 0.7 2.7 0.8 5.3 0.7 2 0.8 4.6 0.4 229 21 220 255 21.4 0 22 21.1 07/10/2005 18:50:00 1.6 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1.2 0.7 3 0.4 214 23 194 255 21.3 0 21.7 21.1 07/10/2005 19:00:00 1.1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 201 21 186 255 21.1 0 21.7 21.1 07/10/2005 19:10:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.4 0.7 3.4 0.4 257 15 260 255 21.2 0 21.7 21.1 07/10/2005 19:20:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 276 28 290 255 21.3 0.1 21.7 21.1 07/10/2005 19:30:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 265 13 275 255 21.3 0.1 21.7 21.1 07/10/2005 19:40:00 0.5 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 293 23 273 255 21.3 0 21.7 21.1 07/10/2005 19:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 294 64 193 255 21 0 21.7 20.8 07/10/2005 20:00:00 2 0.9 3.8 0.4 1.8 1 3.8 0.4 1.4 0.8 3 0.4 34 16 11 255 20.6 0.2 21.1 20.3 07/10/2005 20:10:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 63 26 84 255 20.2 0 20.8 20 07/10/2005 20:20:00 1.3 0.7 3 0.4 1.1 0.6 3.4 0.4 0.9 0.5 2.6 0.4 99 22 59 255 19.9 0 20.5 19.7 07/10/2005 20:30:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.6 0.5 3 0.4 318 38 24 255 20 0 20.5 19.7 07/10/2005 20:40:00 2.6 0.8 5.3 0.7 2.4 0.8 4.9 0.4 1.5 0.8 4.6 0.4 19 20 36 255 19.7 0 20.5 19.4 07/10/2005 20:50:00 3.7 0.6 5.3 1.9 3.6 0.6 4.9 1.9 3.1 0.7 4.9 1.1 32 13 37 255 19.6 0 19.7 19.4 07/10/2005 21:00:00 2.2 0.5 3.8 1.1 1.8 0.7 3.4 0.7 1.4 0.7 3 0.4 348 17 7 255 19.2 0 19.7 18.8 07/10/2005 21:10:00 1.9 0.4 3 1.1 1.7 0.5 3 0.4 0.8 0.5 2.3 0.4 311 13 304 255 18.5 0.2 18.8 18.2 07/10/2005 21:20:00 1.6 0.4 2.6 0.7 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 328 15 301 255 18 0 18.2 17.7 07/10/2005 21:30:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.7 0.4 1.9 0.4 2 15 355 255 17.5 0.1 17.7 17.1 07/10/2005 21:40:00 1.1 0.8 2.6 0.4 1 0.7 2.6 0.4 0.5 0.4 2.3 0.4 46 28 32 255 17.2 0 17.4 16.8 07/10/2005 21:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 24 12 255 17.2 0 17.1 16.8 07/10/2005 22:00:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 13 0 12 255 17.2 0 17.1 17.1 07/10/2005 22:10:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 12 0 12 255 17.2 0 17.1 16.8 07/10/2005 22:20:00 1 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.1 0.4 18 9 12 255 17 0 17.1 16.8 07/10/2005 22:30:00 1.6 0.4 2.6 0.4 1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 339 16 343 255 16.8 0 17.1 16.8 07/10/2005 22:40:00 1.9 0.5 3.4 0.7 1.4 0.5 2.6 0.4 1 0.6 2.6 0.4 344 10 348 255 16.7 0 17.1 16.6 07/10/2005 22:50:00 2.2 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.3 0.6 3 0.4 315 17 340 255 16.3 0.1 16.8 16 07/10/2005 23:00:00 2 0.4 3 0.7 1.8 0.4 2.6 0.4 1 0.4 1.9 0.4 303 12 300 255 15.9 0 16.3 15.7 07/10/2005 23:10:00 2.1 0.4 3 0.7 1.9 0.5 3 0.7 1.1 0.6 2.3 0.4 298 12 302 255 15.4 0.2 16 15.2 07/10/2005 23:20:00 1.8 0.4 3 0.4 1.6 0.5 3 0.4 1 0.5 2.3 0.4 295 13 278 255 15.1 0 15.5 15.2 07/10/2005 23:30:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 287 14 295 255 15 0 15.5 14.9 07/10/2005 23:40:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 297 8 304 255 14.8 0.1 15.2 14.6 07/10/2005 23:50:00 1.6 0.5 2.6 0.7 1.3 0.6 2.6 0.4 0.8 0.5 1.9 0.4 284 15 285 255 14.6 0 15.2 14.6 07/11/2005 00:00:00 2.1 0.8 3.4 0.4 2 0.8 3 0.4 1.2 0.6 2.6 0.4 260 9 263 255 14.6 0.1 15.2 14.4 07/11/2005 00:10:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.3 1.9 0.4 58 43 22 255 14.6 0 15.2 14.4 07/11/2005 00:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 77 90 206 255 14.3 0.1 14.9 14.1 07/11/2005 00:30:00 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 17 12 27 255 14 0.1 14.4 13.8 07/11/2005 00:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 21 5 12 255 13.9 0 14.4 13.8 07/11/2005 00:50:00 1.1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.3 1.5 0.4 79 23 49 255 14 0.1 14.6 13.8 07/11/2005 01:00:00 1 0.4 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.2 1.1 0.4 131 15 110 255 13.9 0 14.6 13.8 07/11/2005 01:10:00 1.4 0.3 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 79 17 83 255 14.1 0.1 14.6 13.8 07/11/2005 01:20:00 1.9 0.4 3 0.7 1.7 0.4 3 0.4 1.2 0.5 2.6 0.4 74 12 90 255 14.1 0.1 14.6 14.1 07/11/2005 01:30:00 1.2 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 41 16 68 255 14.3 0 14.9 14.4 07/11/2005 01:40:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 0.6 0.3 1.9 0.4 15 12 35 255 14.3 0 14.9 14.4 07/11/2005 01:50:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 1.2 0.5 2.3 0.4 64 26 91 255 14.4 0 14.9 14.4 07/11/2005 02:00:00 1.6 0.8 3 0.4 1.4 0.8 2.6 0.4 1.2 0.6 2.3 0.4 100 26 103 255 14.6 0 15.2 14.6 07/11/2005 02:10:00 2.3 0.8 3.4 0.4 2.1 0.8 3.4 0.4 1.5 0.7 3 0.4 104 14 88 255 14.6 0.1 15.2 14.6 07/11/2005 02:20:00 2.3 0.7 3.8 0.7 2 0.8 3.4 0.4 1.5 0.8 3 0.4 94 10 86 255 14.6 0.1 15.2 14.6 07/11/2005 02:30:00 1.6 0.5 3 0.4 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 112 20 96 255 14.6 0.1 15.2 14.6 07/11/2005 02:40:00 1.6 0.5 3 0.4 1.3 0.5 2.3 0.4 1.3 0.4 2.3 0.4 132 15 128 255 14.4 0.1 15.2 14.1 07/11/2005 02:50:00 2.4 0.4 3.4 1.5 2.2 0.5 3.4 1.1 1.8 0.5 3 0.4 118 12 119 255 13.9 0 14.4 13.8 07/11/2005 03:00:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.7 0.5 3 0.4 120 14 125 255 14.1 0 14.6 13.8 07/11/2005 03:10:00 2.2 0.4 3.4 1.1 2.1 0.5 3 0.4 1.7 0.5 2.6 0.4 102 15 85 255 14.2 0 14.6 14.1 07/11/2005 03:20:00 2.3 0.5 3.4 0.7 2.1 0.6 3.4 0.4 1.7 0.5 3.4 0.7 110 13 76 255 14.2 0 14.9 14.1 07/11/2005 03:30:00 2.4 0.5 3.8 1.1 2.1 0.6 3.4 0.4 1.4 0.6 3.4 0.4 93 10 82 255 14.2 0 14.6 14.1 07/11/2005 03:40:00 2.8 0.5 3.8 1.5 2.6 0.5 3.8 0.7 1.9 0.5 3 0.4 81 13 71 255 13.9 0 14.1 13.8 07/11/2005 03:50:00 2.7 0.6 4.2 1.1 2.6 0.7 4.2 1.1 1.9 0.6 3.4 0.4 57 16 39 255 13.9 0.1 14.6 13.8 07/11/2005 04:00:00 1.9 0.5 3 0.7 1.6 0.6 3 0.4 1.5 0.5 2.6 0.4 43 13 58 255 14.5 0.1 15.2 14.4 07/11/2005 04:10:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 70 18 79 255 14.6 0 15.2 14.6 07/11/2005 04:20:00 1.8 0.5 3 0.4 1.5 0.6 2.6 0.4 1 0.6 2.3 0.4 90 16 119 255 14.5 0 15.2 14.6 07/11/2005 04:30:00 2.3 0.6 3.8 0.7 2.1 0.6 3.8 0.4 1.7 0.6 3 0.4 74 12 80 255 14.5 0 15.2 14.4 07/11/2005 04:40:00 3.2 0.9 5.3 1.5 3.1 1 5.3 1.1 2.4 1 4.2 0.4 66 15 74 255 14.9 0 15.5 14.6 07/11/2005 04:50:00 3.1 0.7 4.9 0.7 3 0.8 4.9 1.1 2.4 0.9 4.9 0.7 67 17 53 255 15.2 0.1 15.7 15.2 07/11/2005 05:00:00 3.2 0.7 4.9 1.5 3.1 0.8 4.9 1.5 2.6 0.7 3.8 0.7 61 14 65 255 15.4 0 15.7 15.5 07/11/2005 05:10:00 2.3 0.7 4.6 0.7 2.1 0.8 4.6 0.7 1.7 0.6 3.4 0.4 51 16 54 255 15.4 0 16 15.2 07/11/2005 05:20:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.6 0.5 3 0.4 68 18 69 255 15.4 0 16 15.5 07/11/2005 05:30:00 2.9 0.7 4.6 0.4 2.8 0.8 4.2 0.4 2.1 0.8 3.8 0.4 73 19 63 255 15.4 0 16 15.5 07/11/2005 05:40:00 2.8 0.6 4.9 1.5 2.7 0.6 4.6 0.7 2 0.6 3.8 0.4 71 14 49 255 15.5 0 16 15.5 07/11/2005 05:50:00 2.3 0.5 3.4 1.1 2.2 0.5 3 0.4 1.5 0.6 3 0.4 81 15 78 255 15.6 0 16.3 15.5 07/11/2005 06:00:00 2.4 0.5 3.4 0.7 2.2 0.6 3.4 0.4 1.8 0.5 3 0.4 65 16 67 255 16 0 16.6 15.7 07/11/2005 06:10:00 1.8 0.5 3 0.4 1.5 0.7 3 0.4 1.2 0.6 2.6 0.4 74 10 81 255 16.4 0.2 17.1 16 07/11/2005 06:20:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 86 11 81 255 16.6 0 17.1 16.3 07/11/2005 06:30:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 98 12 97 255 16.2 0.1 16.8 16.3 07/11/2005 06:40:00 1.8 0.5 3 0.7 1.6 0.6 3 0.4 1.4 0.7 3.4 0.4 75 16 49 255 17.7 0.4 18.5 16.8 07/11/2005 06:50:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.1 2.4 0.5 3.8 1.1 44 13 18 255 19.1 0.2 19.4 18.5 07/11/2005 07:00:00 2.9 0.6 4.2 1.5 2.8 0.6 4.2 1.5 2.5 0.7 4.2 0.4 41 10 40 255 19.3 0 19.4 19.1 07/11/2005 07:10:00 2.7 0.5 3.8 0.7 2.6 0.6 3.8 0.4 2.3 0.6 4.2 0.7 28 14 41 255 19.5 0.1 20.3 19.1 07/11/2005 07:20:00 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 1 0.6 2.6 0.4 358 11 12 255 19.9 0 20.5 19.4 07/11/2005 07:30:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 353 15 330 255 20 0.2 20.5 19.4 07/11/2005 07:40:00 0.7 0.4 1.9 0.4 0.5 0.4 2.3 0.4 0.6 0.4 1.9 0.4 35 30 66 255 19.8 0 20.3 19.7 07/11/2005 07:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 66 18 43 255 20 0 20.3 19.7 07/11/2005 08:00:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 81 12 58 255 20 0 20.3 20 07/11/2005 08:10:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.1 0.5 2.6 0.4 45 21 35 255 20.3 0.1 21.1 20 07/11/2005 08:20:00 1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 45 22 23 255 20.8 0.1 21.1 20.5 07/11/2005 08:30:00 1.1 0.4 2.3 0.4 0.9 0.4 2.3 0.4 1 0.4 1.9 0.4 77 16 65 255 21 0 21.4 20.8 07/11/2005 08:40:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 23 36 356 255 21.2 0 21.7 21.1 07/11/2005 08:50:00 1.4 0.5 2.6 0.4 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 357 19 355 255 21.8 0.3 22.6 21.1 07/11/2005 09:00:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 2.3 0.4 347 17 344 255 22.4 0.1 22.9 22 07/11/2005 09:10:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 259 76 355 255 22.4 0 22.9 22.3 07/11/2005 09:20:00 1.5 0.8 3 0.4 1.3 0.8 3 0.4 1.3 0.8 3 0.4 196 51 253 255 22.4 0.1 22.9 21.7 07/11/2005 09:30:00 1.3 0.7 3 0.4 1.1 0.8 3 0.4 1.2 0.7 3 0.4 229 58 232 255 22.2 0 22.6 21.7 07/11/2005 09:40:00 1.1 0.6 2.6 0.4 1 0.6 3 0.4 1.1 0.6 2.6 0.4 206 82 226 255 22.7 0 22.9 22.3 07/11/2005 09:50:00 1.4 0.7 3 0.4 1.2 0.7 3 0.4 1.2 0.7 3.4 0.4 179 64 232 255 22.9 0.2 23.5 22.3 07/11/2005 10:00:00 1.6 0.6 3.8 0.4 1.5 0.6 3.4 0.4 1.4 0.8 3.4 0.4 237 32 255 255 22.8 0.2 23.5 22.3 07/11/2005 10:10:00 1 0.7 3 0.4 0.8 0.6 3 0.4 0.9 0.6 3 0.4 235 69 209 255 23.3 0.2 23.5 22.6 07/11/2005 10:20:00 1.6 0.9 3.8 0.4 1.5 1 3.8 0.4 1.3 0.9 3 0.4 54 61 14 255 23.8 0.3 24.4 23.5 07/11/2005 10:30:00 1.7 0.7 3.8 0.4 1.6 0.7 3.4 0.4 1.6 0.6 3.4 0.4 37 28 53 255 24.1 0.1 24.4 23.8 07/11/2005 10:40:00 1.2 0.6 3 0.4 1 0.6 3 0.4 1.2 0.6 3 0.4 20 58 352 255 24.1 0.2 24.4 23.8 07/11/2005 10:50:00 1 0.8 3 0.4 0.9 0.7 2.6 0.4 0.9 0.6 2.6 0.4 209 53 323 255 23.8 0.2 24.4 23.5 07/11/2005 11:00:00 2.4 1.5 6.1 0.4 2.3 1.5 6.1 0.4 2 1.2 5.3 0.4 351 56 69 255 24.7 0 25 24.4 07/11/2005 11:10:00 3.4 1.5 8 0.4 3.2 1.5 8 0.4 2.6 1.3 6.5 0.4 0 28 15 255 25 0 25.3 25 07/11/2005 11:20:00 2.5 1.1 5.7 0.4 2.4 1.1 5.7 0.4 2.2 1 5.7 0.4 80 72 113 255 24.9 0.4 25.6 24.1 07/11/2005 11:30:00 1.7 1 4.2 0.4 1.6 1 4.2 0.4 1.5 1 4.2 0.4 44 58 54 255 24.2 0.2 25 23.8 07/11/2005 11:40:00 2.4 0.8 4.2 0.4 2.4 0.9 4.6 0.4 2.3 1 4.2 0.4 149 43 162 255 24.1 0.3 24.7 23.8 07/11/2005 11:50:00 2.1 0.9 4.6 0.4 2 1 4.6 0.4 2.1 0.9 4.2 0.4 209 61 251 255 23.6 0.2 24.4 23.5 07/11/2005 12:00:00 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.6 0.7 3.4 0.4 269 28 229 255 24.9 0.3 25.3 24.4 07/11/2005 12:10:00 1.4 0.6 2.6 0.4 1.2 0.7 3 0.4 1.3 0.7 3 0.4 5 27 309 255 25.2 0 25.6 25.3 07/11/2005 12:20:00 1.9 1 4.9 0.4 1.8 1 4.6 0.4 1.5 0.9 4.2 0.4 248 69 225 255 25.5 0 25.9 25.3 07/11/2005 12:30:00 2.4 0.6 3.4 0.7 2.3 0.6 3.4 0.7 1.9 0.6 3.4 0.4 218 21 208 255 24.4 0.6 25.6 23.5 07/11/2005 12:40:00 1.8 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.4 0.7 3.8 0.4 210 19 206 255 23 0.1 23.5 22.9 07/11/2005 12:50:00 2.5 0.6 4.2 0.7 2.3 0.7 3.8 0.4 2 0.6 3.4 0.4 209 22 260 255 22.8 0 23.2 22.6 07/11/2005 13:00:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1.3 0.6 3 0.4 224 20 223 255 22.7 0.1 22.9 22.6 07/11/2005 13:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.9 0.4 137 90 91 255 22.8 0 22.9 22.9 07/11/2005 13:20:00 0.8 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.6 0.4 1.9 0.4 243 117 27 255 23.1 0 23.8 22.9 07/11/2005 13:30:00 1.5 0.7 3.8 0.4 1.3 0.7 3 0.4 1.1 0.7 3.4 0.4 209 47 252 255 24.1 0 24.4 23.5 07/11/2005 13:40:00 1.4 0.8 3.8 0.4 1.3 0.8 3.8 0.4 1.2 0.7 3 0.4 227 53 277 255 23.6 0.2 24.4 23.5 07/11/2005 13:50:00 1.2 0.7 3.4 0.4 1 0.7 3 0.4 0.9 0.6 3 0.4 257 33 204 255 23.5 0 23.8 23.5 07/11/2005 14:00:00 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 188 47 132 255 23.6 0 23.8 23.5 07/11/2005 14:10:00 2.1 0.8 3.8 0.7 1.9 0.8 3.8 0.4 2 0.8 3.8 0.4 149 41 141 255 24 0.1 24.4 23.8 07/11/2005 14:20:00 1.6 0.7 3.4 0.4 1.4 0.8 3 0.4 1.4 0.6 3.4 0.4 206 41 235 255 24 0 24.4 23.8 07/11/2005 14:30:00 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.9 0.6 2.6 0.4 156 32 242 255 23.6 0.2 24.4 23.2 07/11/2005 14:40:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 263 30 307 255 23.5 0.3 25 23.2 07/11/2005 14:50:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 182 47 174 255 25.3 0.3 25.9 24.4 07/11/2005 15:00:00 2.5 0.9 4.6 0.4 2.4 1 4.6 0.4 2.2 0.9 3.8 0.4 87 86 150 255 25.9 0.1 26.2 25.6 07/11/2005 15:10:00 4 0.9 8 1.9 3.8 0.9 8 1.5 3.5 1 6.8 1.1 1 47 321 255 26.4 0 26.5 26.2 07/11/2005 15:20:00 2.2 1 6.1 0.4 2 1.2 6.5 0.4 1.5 0.8 3.8 0.4 294 79 6 255 26.7 0 27.1 26.5 07/11/2005 15:30:00 3.1 1.2 6.1 0.4 2.8 1.3 5.7 0.4 2.4 1.1 5.7 0.4 292 49 294 255 26.5 0.1 26.8 26.2 07/11/2005 15:40:00 3.2 1.1 5.7 1.1 3 1.2 5.7 0.7 2.1 0.8 5.3 0.4 329 27 310 255 26.9 0 27.4 26.8 07/11/2005 15:50:00 3.5 0.8 5.3 0.7 3.3 0.8 5.3 0.4 2.5 1 5.3 0.4 318 35 13 255 27 0.1 27.4 26.5 07/11/2005 16:00:00 3.6 1.2 6.1 0.4 3.5 1.2 6.1 0.4 2.7 1.2 5.7 0.4 358 29 11 255 27 0.1 27.4 26.8 07/11/2005 16:10:00 5.2 1 7.2 2.3 5.1 1 6.8 1.9 4 1.4 6.8 1.1 16 18 2 255 27 0.6 27.7 25.9 07/11/2005 16:20:00 5.8 1 8.4 3 5.8 1 8 3 4.8 1.2 8 2.3 31 15 19 255 25.6 0.3 25.9 24.7 07/11/2005 16:30:00 5.9 1 8 3.4 5.9 1 8 3.4 5.1 1.1 7.6 2.6 30 12 30 255 24.1 0.2 24.7 23.5 07/11/2005 16:40:00 5.3 1.1 7.6 2.6 5.2 1.1 8 2.6 4 1.2 7.2 1.5 31 20 8 255 23.5 0.1 23.8 23.2 07/11/2005 16:50:00 4.6 0.9 6.8 1.9 4.5 0.9 6.5 1.5 3.5 1 5.7 0.7 16 11 2 255 23 0 23.2 22.9 07/11/2005 17:00:00 4.5 0.8 6.5 3 4.4 0.8 6.5 2.6 3.7 1 6.1 1.9 27 13 12 255 22.4 0 22.9 22.3 07/11/2005 17:10:00 5.5 1.2 8.4 2.6 5.4 1.2 8 2.6 4.5 1.3 7.2 1.1 24 15 7 255 22 0 22.3 22 07/11/2005 17:20:00 4.9 1 7.2 2.6 4.9 1 7.6 2.3 3.8 1.3 6.8 1.5 23 13 21 255 22.4 0.2 23.2 22 07/11/2005 17:30:00 4.8 1.2 8.8 2.6 4.8 1.2 8.8 2.3 3.8 1.1 6.5 1.5 28 15 3 255 22.6 0 22.9 22.3 07/11/2005 17:40:00 5.4 1.3 7.6 2.3 5.3 1.3 8 2.3 4.3 1.5 7.2 1.1 24 15 28 255 21.9 0.2 22.3 21.1 07/11/2005 17:50:00 4.8 1.2 8 1.9 4.7 1.2 8.4 1.9 3.5 1.3 7.6 0.4 23 17 28 255 21.5 0 21.7 21.1 07/11/2005 18:00:00 5 1 7.2 2.6 4.9 1 7.2 2.3 4.1 1.1 6.8 1.1 27 15 35 255 22.1 0.3 22.6 21.7 07/11/2005 18:10:00 4.5 1 7.2 2.6 4.5 1 7.2 2.3 3.3 1.2 6.8 0.7 21 15 22 255 22.4 0 22.9 22.3 07/11/2005 18:20:00 4.2 1.5 7.6 1.1 4.1 1.5 7.6 0.4 3.2 1.5 6.8 0.4 26 18 31 255 21.9 0.2 22.3 21.7 07/11/2005 18:30:00 4 1.3 7.2 1.1 4 1.3 7.6 0.7 3.1 1.3 6.5 0.7 27 22 9 255 22.1 0 22.3 21.7 07/11/2005 18:40:00 5 1.5 7.6 1.5 4.9 1.5 8 1.1 3.8 1.4 7.6 1.1 15 20 61 255 22.2 0 22.6 22.3 07/11/2005 18:50:00 5.3 1.3 8 1.5 5.2 1.4 8 1.5 4.4 1.4 7.2 1.5 32 17 32 255 22.1 0 22.3 22 07/11/2005 19:00:00 4.7 0.9 7.2 2.6 4.6 0.9 7.2 2.3 3.5 1.1 6.1 1.1 15 11 20 255 21.4 0.2 22 20.8 07/11/2005 19:10:00 4.9 0.8 6.8 2.6 4.9 0.8 6.8 2.6 3.5 1 5.7 1.1 13 13 17 255 20.5 0 21.1 20.3 07/11/2005 19:20:00 5.1 1 7.2 2.3 5 1 7.2 2.3 3.6 1.2 6.5 0.4 3 13 358 255 20.3 0 20.8 20.3 07/11/2005 19:30:00 4.5 1.2 8.8 1.9 4.4 1.3 9.1 1.5 3.3 1.5 7.2 0.4 7 17 13 255 20.5 0 21.1 20.3 07/11/2005 19:40:00 5 1.1 8 2.3 4.9 1.2 8 1.9 3.5 1.3 6.8 0.7 5 17 23 255 20.5 0 20.8 20.3 07/11/2005 19:50:00 3.6 0.8 5.3 1.5 3.5 0.9 5.3 1.1 2.5 1.1 4.9 0.4 357 17 347 255 20.3 0.1 20.8 20 07/11/2005 20:00:00 4.4 0.9 6.8 2.3 4.4 0.9 6.8 1.9 2.8 1.1 5.3 0.4 6 11 4 255 20 0 20.5 19.7 07/11/2005 20:10:00 4.2 1 6.5 1.5 4.1 1 6.5 1.5 3.2 1.3 5.7 0.4 14 13 12 255 19.9 0 20.5 19.7 07/11/2005 20:20:00 3.4 0.9 6.1 1.1 3.3 0.9 5.3 1.1 2.2 1.1 4.6 0.4 3 15 2 255 20 0 20.5 20 07/11/2005 20:30:00 1.9 0.8 4.2 0.4 1.7 0.9 4.2 0.4 1.2 0.8 3.4 0.4 6 14 6 255 20.1 0 20.5 20 07/11/2005 20:40:00 2.2 0.7 3.8 0.7 1.9 0.8 3.8 0.4 1.1 0.9 3.4 0.4 8 19 347 255 20 0 20.3 20 07/11/2005 20:50:00 3.1 1.2 6.8 0.4 2.9 1.3 6.5 0.4 1.9 1.1 5.3 0.4 4 17 10 255 20 0 20 19.7 07/11/2005 21:00:00 5 1.1 8 2.3 4.9 1.2 7.6 1.9 3.7 1.3 7.2 1.1 359 32 27 255 19.8 0 20 19.7 07/11/2005 21:10:00 2 0.8 4.2 0.4 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 325 24 319 255 19.6 0 20 19.4 07/11/2005 21:20:00 2.5 0.8 4.6 0.7 2.2 0.9 4.6 0.4 1.4 0.8 4.2 0.4 354 15 355 255 19.2 0.1 19.4 19.1 07/11/2005 21:30:00 1.8 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.6 2.6 0.4 328 35 4 255 18.9 0 19.1 18.5 07/11/2005 21:40:00 1.4 0.5 3 0.4 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 298 16 280 255 18.8 0 18.8 18.5 07/11/2005 21:50:00 1.3 0.5 3 0.4 0.8 0.5 2.6 0.4 0.7 0.4 1.9 0.4 322 23 352 255 18.6 0 18.8 18.5 07/11/2005 22:00:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 351 13 1 255 18.4 0 18.5 18.2 07/11/2005 22:10:00 1.5 0.9 3 0.4 1.4 0.8 2.6 0.4 1 0.7 2.6 0.4 26 17 33 255 18 0 18.2 17.7 07/11/2005 22:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 350 11 17 255 17.5 0.1 17.7 17.1 07/11/2005 22:30:00 1.4 0.9 3 0.4 1.2 0.9 2.6 0.4 1 0.7 2.3 0.4 8 21 27 255 17.2 0 17.4 16.8 07/11/2005 22:40:00 2 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.3 0.6 2.6 0.4 29 14 15 255 17 0.1 17.1 16.8 07/11/2005 22:50:00 1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.6 0.5 2.3 0.4 1 20 22 255 16.4 0.2 16.8 16.3 07/11/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 255 255 15.8 0.1 16.3 15.5 07/11/2005 23:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 278 45 244 255 15.2 0.1 15.7 15.2 07/11/2005 23:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 244 0 244 255 14.8 0.1 15.2 14.6 07/11/2005 23:30:00 1.7 0.6 2.6 0.7 1.6 0.7 2.6 0.4 1 0.4 1.9 0.4 226 8 225 255 14.4 0.2 14.9 13.8 07/11/2005 23:40:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.3 1.5 0.4 120 61 212 255 14 0.1 14.6 13.8 07/11/2005 23:50:00 1 0.6 3 0.4 0.9 0.7 2.6 0.4 0.8 0.5 1.9 0.4 214 90 165 255 13.7 0.2 14.4 13.3 07/12/2005 00:00:00 1.2 0.9 3.4 0.4 1 0.9 3.4 0.4 1 0.7 3 0.4 40 90 53 255 13.7 0.1 14.4 13.3 07/12/2005 00:10:00 2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.5 0.6 3 0.4 128 43 92 255 13.5 0 14.1 13.3 07/12/2005 00:20:00 1.8 0.5 3 0.7 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 133 14 136 255 13.2 0 13.8 13 07/12/2005 00:30:00 2.7 0.6 3.8 0.7 2.6 0.7 4.2 0.4 2.1 0.7 4.2 0.4 109 13 114 255 12.9 0.1 13.3 12.7 07/12/2005 00:40:00 2.4 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.4 0.7 3 0.4 115 16 109 255 12.6 0.1 13.3 12.5 07/12/2005 00:50:00 2.1 0.7 4.6 0.7 1.9 0.7 3.8 0.4 1.2 0.7 3 0.4 111 12 97 255 12.3 0 12.7 12.2 07/12/2005 01:00:00 3.5 0.6 4.9 1.9 3.3 0.6 4.6 1.1 2.2 0.6 4.2 0.7 106 15 105 255 12.3 0 12.7 12.2 07/12/2005 01:10:00 3.9 0.8 5.7 1.5 3.8 0.8 5.7 1.5 2.6 0.8 4.6 0.7 108 13 116 255 12.6 0 13 12.5 07/12/2005 01:20:00 4.4 0.6 6.1 2.6 4.4 0.6 6.1 2.3 3.3 0.7 4.9 1.9 99 9 117 255 13.1 0 13.5 12.7 07/12/2005 01:30:00 4.4 0.6 6.1 3 4.4 0.6 6.1 2.6 3.3 0.8 5.3 0.7 95 11 113 255 13.3 0 13.3 13 07/12/2005 01:40:00 3.9 0.7 6.1 1.9 3.9 0.7 5.7 1.9 2.7 0.7 4.6 0.7 88 13 73 255 13.1 0 13.5 13 07/12/2005 01:50:00 3.4 0.6 5.3 1.9 3.3 0.7 5.7 1.9 2.3 0.7 4.2 0.4 85 11 77 255 13 0 13.3 12.7 07/12/2005 02:00:00 2.4 0.9 4.6 1.1 2.3 1 4.2 0.4 1.5 0.9 3.8 0.4 77 10 65 255 12.7 0.1 13.3 12.2 07/12/2005 02:10:00 2.5 0.5 4.2 1.1 2.3 0.5 3.8 0.7 1.2 0.5 2.6 0.4 84 14 64 255 11.7 0.2 12.5 11.4 07/12/2005 02:20:00 3.2 0.6 4.6 1.9 3.1 0.6 4.9 1.5 1.9 0.6 4.2 0.7 81 12 94 255 11.2 0 11.7 11.1 07/12/2005 02:30:00 2.9 0.6 4.2 1.1 2.7 0.6 4.2 1.1 1.6 0.7 3 0.4 83 12 90 255 10.9 0.1 11.1 10.6 07/12/2005 02:40:00 2.9 0.5 4.2 1.9 2.7 0.6 4.2 0.7 1.5 0.7 3.4 0.4 84 11 88 255 10.6 0 11.1 10.6 07/12/2005 02:50:00 2.8 0.6 4.2 0.7 2.6 0.6 4.2 0.7 1.4 0.6 3 0.4 85 11 83 255 10.5 0 10.9 10.6 07/12/2005 03:00:00 3.8 0.8 6.1 1.9 3.7 0.9 6.1 1.9 2.6 0.8 4.6 0.4 79 11 97 255 10.7 0.2 11.4 10.6 07/12/2005 03:10:00 3.9 0.7 5.7 1.5 3.9 0.7 5.7 1.5 2.7 0.7 4.6 0.7 76 11 74 255 11.5 0 11.7 11.4 07/12/2005 03:20:00 4 0.6 5.3 1.9 3.9 0.7 5.7 1.5 2.9 0.8 4.9 0.7 83 9 84 255 12 0.1 12.5 11.7 07/12/2005 03:30:00 4 0.7 5.7 2.3 4 0.7 5.7 1.9 2.7 0.8 5.7 0.4 87 11 83 255 12.6 0.1 12.7 12.2 07/12/2005 03:40:00 4.2 0.7 5.7 1.9 4.1 0.7 5.7 1.9 2.9 0.8 4.9 1.1 85 11 74 255 13.1 0 13.3 12.7 07/12/2005 03:50:00 3.9 0.7 6.1 2.3 3.8 0.7 5.3 1.9 3 0.7 4.6 1.5 96 9 89 255 12.9 0.1 13.3 12.7 07/12/2005 04:00:00 4.4 0.5 6.1 2.6 4.3 0.6 5.3 2.6 3.2 0.6 4.9 1.9 96 9 87 255 13 0 13.3 12.7 07/12/2005 04:10:00 4.4 0.7 6.5 2.6 4.4 0.7 6.1 2.3 3.3 0.8 4.9 1.1 95 12 87 255 12.9 0 13 12.7 07/12/2005 04:20:00 3.5 0.7 4.9 1.5 3.4 0.7 4.9 1.5 2.7 0.7 5.3 0.7 104 12 106 255 12.9 0 13 12.7 07/12/2005 04:30:00 3.9 0.8 6.1 1.9 3.8 0.8 6.5 1.5 2.9 0.8 5.3 1.1 96 15 80 255 12.8 0 13 12.7 07/12/2005 04:40:00 3.7 0.6 5.3 2.3 3.7 0.6 5.3 2.3 2.9 0.7 4.6 1.1 95 9 95 255 12.9 0 13 12.7 07/12/2005 04:50:00 2.3 0.9 4.2 0.4 2.2 1 4.2 0.4 1.4 0.8 3.4 0.4 91 18 89 255 12.9 0 13 12.7 07/12/2005 05:00:00 1 0.6 3 0.4 0.8 0.7 3 0.4 0.7 0.5 2.3 0.4 72 23 55 255 12.5 0 12.7 12.2 07/12/2005 05:10:00 1.3 0.7 3 0.4 1 0.7 2.6 0.4 0.8 0.5 2.3 0.4 82 28 86 255 11.9 0.2 12.2 11.7 07/12/2005 05:20:00 2.4 0.6 4.2 1.1 2.2 0.6 4.2 1.1 1.4 0.7 3 0.4 88 15 109 255 11.7 0 11.9 11.7 07/12/2005 05:30:00 2.9 0.7 4.6 1.1 2.8 0.7 4.9 0.7 1.9 0.7 3.4 0.4 93 15 93 255 12.1 0.2 12.5 11.7 07/12/2005 05:40:00 2.6 0.7 4.2 1.1 2.5 0.8 4.6 0.4 1.6 0.7 3.8 0.4 89 23 88 255 12.3 0 12.5 12.2 07/12/2005 05:50:00 3.6 0.7 5.3 1.5 3.5 0.8 5.7 1.1 2.7 0.9 4.6 0.4 90 15 73 255 13.2 0.6 14.4 12.5 07/12/2005 06:00:00 4.1 0.7 5.7 2.3 4 0.7 5.3 2.3 3.1 0.8 4.9 1.1 105 11 100 255 14.4 0 15.2 14.4 07/12/2005 06:10:00 4.3 0.7 5.7 2.3 4.2 0.7 6.1 2.3 3.3 0.8 5.7 1.5 103 11 79 255 14.9 0.2 15.5 14.6 07/12/2005 06:20:00 3.8 0.8 5.3 1.5 3.7 0.8 5.3 0.7 3 0.9 5.3 1.1 94 14 95 255 15.9 0.4 16.8 15.2 07/12/2005 06:30:00 4.2 0.7 6.1 2.6 4.1 0.7 5.7 2.3 3.4 0.7 4.9 1.9 96 12 95 255 15.9 0.1 16.6 15.7 07/12/2005 06:40:00 3.7 0.6 4.9 1.9 3.6 0.6 4.9 1.9 3 0.6 4.6 1.5 99 11 102 255 15.9 0 16.6 15.7 07/12/2005 06:50:00 3.8 0.7 5.7 2.3 3.7 0.7 5.7 1.9 3.3 0.6 4.9 1.9 99 12 83 255 16.2 0.2 16.8 15.7 07/12/2005 07:00:00 3.7 0.6 5.3 2.3 3.6 0.7 5.3 1.9 2.8 0.7 5.3 1.1 92 12 106 255 16.4 0.1 16.8 16.3 07/12/2005 07:10:00 3.7 0.8 5.3 1.1 3.6 0.8 4.9 1.1 3 0.9 4.9 0.4 98 13 121 255 16.2 0.1 16.8 16.3 07/12/2005 07:20:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.9 2.8 0.6 4.6 1.1 98 10 96 255 16.2 0.1 16.8 16.3 07/12/2005 07:30:00 3.1 0.7 4.6 1.5 3 0.7 4.2 1.1 2.2 0.7 3.8 0.4 86 11 89 255 16.1 0 16.8 16 07/12/2005 07:40:00 3.6 0.9 6.5 1.5 3.5 1 6.5 1.1 3.1 1 5.3 0.7 61 13 66 255 16.3 0.1 16.8 16 07/12/2005 07:50:00 3.6 1 5.7 1.5 3.6 1 5.7 1.1 3.1 0.7 5.3 1.1 54 15 66 255 16.9 0.2 17.4 16.8 07/12/2005 08:00:00 2.5 0.7 4.2 0.4 2.3 0.7 3.8 0.4 1.9 0.8 3.8 0.4 72 18 35 255 18.2 0.5 19.4 17.4 07/12/2005 08:10:00 2.4 0.8 4.6 0.4 2.2 0.9 4.6 0.4 2.1 0.9 4.2 0.4 69 28 47 255 19 0 19.4 18.8 07/12/2005 08:20:00 3 1.1 5.3 0.4 2.9 1.2 5.3 0.4 2.4 1 4.6 0.4 37 21 34 255 18.9 0.1 19.4 18.5 07/12/2005 08:30:00 4.8 1 7.2 2.3 4.7 1 7.6 1.9 3.8 1 7.2 1.5 29 18 9 255 20.2 0.4 21.1 19.4 07/12/2005 08:40:00 6.5 1.7 11.5 2.6 6.5 1.7 11.8 2.6 5 1.7 10.7 0.7 24 18 48 255 20.9 0.1 21.4 20.5 07/12/2005 08:50:00 6.3 1.5 10.7 1.9 6.2 1.6 10.7 1.9 5 1.5 9.5 1.1 22 16 44 255 21.3 0.1 21.7 21.1 07/12/2005 09:00:00 5.5 1.2 8.8 2.6 5.4 1.2 8.8 2.3 4.5 1.3 7.2 1.1 16 17 356 255 21.6 0 22.3 21.1 07/12/2005 09:10:00 5.3 1.2 8.4 1.5 5.1 1.2 8 1.1 3.7 1.3 7.6 0.7 3 19 6 255 21.9 0 22 21.4 07/12/2005 09:20:00 4.4 1.2 6.8 1.5 4.2 1.2 6.8 1.5 3.2 1.3 6.8 0.7 357 19 9 255 21.4 0.2 22 21.1 07/12/2005 09:30:00 4.7 1.1 7.2 2.3 4.4 1.2 7.2 1.9 3.3 1 6.1 1.1 350 20 358 255 21.3 0 21.7 21.1 07/12/2005 09:40:00 4 1.3 7.6 1.1 3.8 1.4 7.2 0.7 2.9 1.4 6.1 0.4 354 20 14 255 21.9 0 22 21.7 07/12/2005 09:50:00 4.7 1.6 8.4 1.9 4.5 1.7 8.8 1.1 3.3 1.5 7.2 0.7 358 29 8 255 22 0 22.3 21.7 07/12/2005 10:00:00 5.6 1.2 8 1.1 5.5 1.3 8 0.7 4 1.3 6.8 0.7 5 17 7 255 22.4 0 22.9 22.3 07/12/2005 10:10:00 5.1 1 8 2.3 4.7 1 7.6 2.3 3.7 1.2 6.8 0.7 352 20 12 255 22.9 0 23.2 22.9 07/12/2005 10:20:00 4.1 1.2 7.2 0.4 3.9 1.2 7.2 0.7 3.2 1.4 6.8 0.4 353 17 349 255 22.9 0.1 23.5 22.9 07/12/2005 10:30:00 4.4 1.1 6.8 1.9 4.1 1.2 7.2 1.9 3.2 1.3 6.8 0.7 348 22 3 255 22.4 0.1 23.2 22.3 07/12/2005 10:40:00 4.4 1.1 6.8 1.5 4 1.2 6.8 1.1 3.4 1.1 5.7 0.7 351 26 18 255 23 0.3 23.8 22.6 07/12/2005 10:50:00 2.8 1 6.5 0.7 2.5 1 5.7 0.4 2.2 1 4.9 0.4 337 24 340 255 23.5 0.1 24.1 23.5 07/12/2005 11:00:00 4.9 1.3 7.6 1.1 4.9 1.3 7.6 0.4 3.6 1.3 6.8 0.7 14 15 14 255 24.2 0.1 24.7 23.8 07/12/2005 11:10:00 4.4 1.1 6.8 1.5 4.3 1.2 7.2 1.1 3.3 1.3 6.5 0.7 4 18 17 255 24.1 0.1 24.4 23.8 07/12/2005 11:20:00 4.4 1.2 7.6 1.5 4.3 1.2 7.6 0.7 3 1.2 7.2 0.4 1 18 14 255 23.1 0.2 23.8 22.9 07/12/2005 11:30:00 4.3 0.8 6.5 2.3 4.2 0.9 6.1 1.9 3.3 1 5.3 0.7 15 13 359 255 23.1 0.2 23.5 22.9 07/12/2005 11:40:00 4.4 1.2 6.8 1.5 4.2 1.3 7.2 1.1 3.3 1.4 6.5 0.4 6 21 345 255 23.9 0.2 24.4 23.5 07/12/2005 11:50:00 3.2 1 5.7 0.7 3.1 1.1 5.7 0.4 2.4 1 4.9 0.4 1 23 2 255 24 0.4 24.7 23.2 07/12/2005 12:00:00 5.1 1.4 8 1.5 5 1.5 8 1.1 3.6 1.2 6.8 1.1 14 17 358 255 24.3 0.4 25 23.8 07/12/2005 12:10:00 3.9 1.1 6.5 1.5 3.7 1.2 6.5 1.1 2.7 1.3 5.7 0.4 0 24 359 255 23.8 0 23.8 23.5 07/12/2005 12:20:00 4.1 1 6.5 1.5 4 1 6.5 1.1 3 1.1 5.3 0.4 1 17 21 255 23.4 0.1 23.8 23.2 07/12/2005 12:30:00 4.3 0.8 5.7 1.5 4.2 0.8 6.1 1.9 3.1 1.2 6.1 0.7 12 15 10 255 23.4 0 23.8 23.2 07/12/2005 12:40:00 2.4 1.3 5.3 0.4 2.3 1.4 5.3 0.4 1.8 1.1 4.9 0.4 358 27 353 255 23.2 0 23.5 23.2 07/12/2005 12:50:00 2.6 0.6 4.2 0.7 2.4 0.7 4.2 0.4 2 0.7 3.4 0.4 350 15 2 255 23.3 0 23.5 23.2 07/12/2005 13:00:00 3 0.8 5.3 1.1 2.8 0.9 4.9 0.4 2.2 0.9 4.9 0.4 1 18 8 255 22.9 0 23.2 22.9 07/12/2005 13:10:00 2.3 1 4.2 0.4 2.1 1.1 3.8 0.4 2 1 3.8 0.4 9 28 14 255 22.9 0 23.2 22.6 07/12/2005 13:20:00 3.2 1.3 6.5 0.4 3.1 1.5 6.1 0.4 2.4 1.2 4.9 0.4 19 22 25 255 22.9 0.3 23.5 22.6 07/12/2005 13:30:00 1.3 0.7 3 0.4 1.1 0.7 3 0.4 1.2 0.7 3 0.4 30 32 97 255 23.7 0 24.1 23.5 07/12/2005 13:40:00 4.8 1.8 8 0.4 4.7 1.8 8.4 0.4 3.5 1.5 6.8 0.4 20 23 4 255 23.8 0 24.1 23.8 07/12/2005 13:50:00 4.3 2.2 10.3 0.4 4.2 2.3 10.3 0.4 3 1.6 8.8 0.4 356 22 358 255 23.5 0.3 23.8 22.6 07/12/2005 14:00:00 6.3 1.7 10.7 2.6 6.2 1.7 10.7 2.3 4.3 1.6 8.8 1.1 6 15 356 255 22.5 0 22.9 22 07/12/2005 14:10:00 6.4 2 11.8 1.1 6.3 2.1 12.2 1.5 4.6 1.9 11.1 0.7 0 17 15 255 21.2 0.4 22 20.5 07/12/2005 14:20:00 5.2 1.6 9.5 2.3 5.1 1.7 9.9 2.3 3.5 1.6 8 0.7 359 17 37 255 20.3 0 21.1 20 07/12/2005 14:30:00 3.3 1.5 7.2 0.4 3 1.4 7.2 0.4 2.1 1.3 6.1 0.4 339 29 328 255 20.1 0 20.5 20 07/12/2005 14:40:00 2.1 1.4 5.7 0.4 1.9 1.4 5.3 0.4 1.9 1.2 5.3 0.4 243 72 318 255 21.3 0.6 22.3 20.5 07/12/2005 14:50:00 3.5 1.1 6.1 0.7 3.5 1.2 6.1 0.4 2.9 1.2 6.1 0.4 213 26 201 255 22.3 0 22.6 22 07/12/2005 15:00:00 3.2 1.1 5.3 0.4 3.2 1.2 5.3 0.4 2.6 1.1 5.3 0.4 216 24 220 255 23.2 0.3 23.8 22.3 07/12/2005 15:10:00 3.1 0.9 4.9 0.7 3 1 4.9 0.4 2.4 1 4.9 0.4 211 18 201 255 23.5 0 24.1 23.5 07/12/2005 15:20:00 2.8 0.9 4.2 0.4 2.7 1 4.6 0.4 2.3 1 4.2 0.4 227 21 220 255 23.8 0 24.4 23.5 07/12/2005 15:30:00 3.3 0.4 4.6 1.9 3.2 0.4 4.6 1.9 3 0.5 4.6 1.1 217 13 217 255 23.7 0.1 24.1 23.2 07/12/2005 15:40:00 2.5 0.8 5.3 0.4 2.4 0.9 4.9 0.4 2.1 0.8 3.8 0.4 244 21 272 255 23.6 0.3 24.1 23.2 07/12/2005 15:50:00 1.6 0.8 4.2 0.4 1.3 1 4.2 0.4 1.4 0.9 4.6 0.4 11 90 262 255 23 0.2 23.8 22.9 07/12/2005 16:00:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.6 2.3 0.4 289 51 315 255 23.1 0.3 23.5 22.9 07/12/2005 16:10:00 1.2 0.8 3 0.4 1.1 0.8 3.4 0.4 1.1 0.8 3 0.4 247 79 183 255 23.2 0 23.5 22.9 07/12/2005 16:20:00 1.9 0.7 4.9 0.4 1.7 0.8 4.6 0.4 1.6 0.7 3.8 0.4 241 82 244 255 23 0 23.2 22.9 07/12/2005 16:30:00 3.1 1.6 6.8 0.4 2.9 1.7 6.8 0.4 2.5 1.1 5.7 0.4 58 36 30 255 22.9 0 23.2 22.9 07/12/2005 16:40:00 5.5 1 8.4 3 5.4 1 8.4 2.6 4.5 1 7.2 1.5 24 17 16 255 23.5 0 23.8 23.2 07/12/2005 16:50:00 5.8 1 8.8 2.6 5.8 1 8.8 2.6 4.6 1.2 7.6 1.5 20 15 18 255 22.7 0.1 23.2 22.3 07/12/2005 17:00:00 5.1 1.2 8.4 2.6 5 1.2 8 2.6 4.2 1.4 7.6 1.1 29 15 23 255 22 0.6 22.9 21.1 07/12/2005 17:10:00 4.3 0.8 6.8 2.6 4.3 0.8 6.5 2.3 3.5 1 6.5 1.5 21 17 25 255 20.7 0.2 21.1 20.3 07/12/2005 17:20:00 4.4 1.2 7.2 1.9 4.3 1.2 6.8 1.9 3.4 1.1 6.1 1.1 21 15 21 255 21 0.3 21.4 20.5 07/12/2005 17:30:00 3.9 1 6.8 1.5 3.9 1.1 6.8 1.5 2.8 1 5.7 0.7 20 17 4 255 21.3 0 22 21.1 07/12/2005 17:40:00 4.6 1.1 6.8 2.3 4.6 1.1 6.8 1.9 3.9 1.1 6.5 1.9 35 17 19 255 21.4 0.1 21.7 20.8 07/12/2005 17:50:00 4.3 1.2 6.8 0.4 4.2 1.2 6.8 0.4 3.2 1.3 6.5 0.4 29 22 20 255 20.8 0.2 21.1 20.5 07/12/2005 18:00:00 4.2 0.7 6.5 2.6 4.1 0.7 6.1 1.9 3.4 1 6.1 0.7 24 12 27 255 20.3 0.1 20.5 20 07/12/2005 18:10:00 5.1 1.7 9.1 1.9 5 1.7 9.1 1.5 4.3 1.5 8 1.5 42 13 48 255 20.4 0 21.1 20 07/12/2005 18:20:00 4.8 0.9 6.8 2.6 4.7 0.9 7.2 2.6 3.8 1 6.1 1.5 34 20 27 255 19.9 0 20.5 19.7 07/12/2005 18:30:00 5.7 1.2 9.1 3 5.6 1.2 9.1 3 4.2 1.5 8 1.9 22 15 26 255 20 0.1 20.5 19.7 07/12/2005 18:40:00 4.7 0.9 6.8 2.3 4.7 0.9 7.2 2.3 3.4 1 6.5 1.1 20 16 0 255 20.3 0 20.8 20.3 07/12/2005 18:50:00 4.7 1.1 8.4 1.9 4.6 1.1 8.4 1.9 3.6 1.2 7.2 0.7 13 19 16 255 20.3 0 20.8 20 07/12/2005 19:00:00 5.2 1 8 2.6 5.1 1.1 7.6 2.3 3.7 1.2 6.8 1.5 16 14 11 255 19.9 0 20.5 19.4 07/12/2005 19:10:00 4.7 1.1 7.6 1.9 4.7 1.2 7.6 1.1 3.4 1.3 7.2 0.4 14 15 20 255 19.5 0 20 19.4 07/12/2005 19:20:00 5.1 1.2 8 1.5 5.1 1.2 8 1.5 3.4 1.3 6.8 0.4 11 16 353 255 19.4 0 20 19.1 07/12/2005 19:30:00 5.3 1 7.6 2.3 5.3 1 7.2 2.3 4.2 1.3 7.2 1.1 26 16 18 255 19.2 0 19.7 19.1 07/12/2005 19:40:00 4.5 1 6.8 1.9 4.5 1 7.2 1.9 3.4 1.2 6.1 0.4 19 15 20 255 19.1 0 19.7 19.1 07/12/2005 19:50:00 4.3 0.8 6.1 2.3 4.3 0.9 6.5 2.3 3.3 1 5.3 1.1 17 12 17 255 18.7 0.2 19.1 18.2 07/12/2005 20:00:00 4.7 1 6.8 2.3 4.6 1 6.8 2.3 3.6 1.1 6.1 0.4 20 13 19 255 18.1 0.1 18.5 17.7 07/12/2005 20:10:00 6.1 1.3 9.1 3.4 6.1 1.3 9.1 3.4 4.8 1.7 8.8 1.1 21 12 11 255 17.6 0 17.7 17.4 07/12/2005 20:20:00 4.7 0.8 6.8 3 4.7 0.8 6.8 3 3.6 1.1 6.1 1.1 19 11 37 255 17.1 0 17.4 16.8 07/12/2005 20:30:00 4.4 0.8 6.8 2.3 4.3 0.8 6.5 2.3 3.3 1 5.7 1.1 18 13 25 255 16.7 0 16.8 16.6 07/12/2005 20:40:00 5.6 1.2 9.5 3 5.5 1.2 9.5 2.6 4.5 1.2 8 1.9 21 13 15 255 16.8 0 16.8 16.6 07/12/2005 20:50:00 6.9 1.2 10.3 3.8 6.9 1.2 10.7 3.8 5.1 1.6 9.9 1.9 19 13 30 255 17 0 17.1 16.8 07/12/2005 21:00:00 6.8 1.2 9.5 3.4 6.8 1.2 9.5 3.4 5.4 1.4 9.9 2.6 24 13 15 255 16.9 0 17.1 16.8 07/12/2005 21:10:00 7.2 1.1 9.9 4.2 7.1 1.1 9.9 4.2 5.6 1.5 8.8 1.9 21 12 48 255 16.8 0 17.1 16.6 07/12/2005 21:20:00 5.6 1.1 8 1.9 5.5 1.1 8.4 1.5 4.2 1.2 7.6 1.9 19 10 37 255 16.4 0.1 16.8 16.3 07/12/2005 21:30:00 6.6 1.5 9.5 2.6 6.6 1.5 9.9 2.6 5.1 1.5 9.5 1.9 12 12 8 255 16.1 0 16.8 16 07/12/2005 21:40:00 6.4 1.4 10.7 3 6.3 1.4 10.3 2.6 4.4 1.5 8.4 1.1 6 17 341 255 15.7 0 16.3 15.7 07/12/2005 21:50:00 5.4 1.3 10.3 2.3 5.3 1.5 10.3 2.6 3.6 1.5 8.4 0.7 7 20 32 255 15.5 0 16 15.2 07/12/2005 22:00:00 8 1.4 11.8 4.6 8 1.5 12.2 4.6 6 1.7 11.5 2.3 15 13 35 255 15.8 0.1 16.3 15.5 07/12/2005 22:10:00 7.5 1.6 12.2 3.4 7.4 1.7 12.2 3.4 5.3 1.7 11.1 1.1 6 14 359 255 15.7 0 16.3 15.5 07/12/2005 22:20:00 7.2 1.6 11.5 4.2 7.2 1.6 11.8 3.8 5.3 1.8 11.1 1.5 11 15 17 255 15.5 0.1 16 15.2 07/12/2005 22:30:00 7.4 1.5 12.2 4.2 7.3 1.5 12.2 4.2 5.4 1.7 10.7 1.9 15 13 20 255 15.4 0 16 15.2 07/12/2005 22:40:00 6.7 2.2 11.5 1.9 6.6 2.2 11.8 1.9 4.9 2.2 9.9 0.7 9 15 12 255 15.5 0.2 16 15.2 07/12/2005 22:50:00 5.8 1.1 8.8 3 5.6 1.2 9.1 3 3.8 1.2 8.8 1.1 359 15 8 255 15 0 15.7 14.9 07/12/2005 23:00:00 5.2 1.5 10.3 2.3 5.1 1.5 10.7 1.9 3.7 1.7 8.8 0.4 17 20 37 255 14.7 0.1 15.5 14.6 07/12/2005 23:10:00 6.2 1.8 10.7 2.6 6.2 1.8 9.9 2.6 5.3 1.6 9.1 1.9 37 21 12 255 15.5 0.2 16 14.9 07/12/2005 23:20:00 5.5 1.3 9.5 2.6 5.5 1.3 9.5 2.3 4.5 1.3 8.4 0.7 41 22 53 255 15.7 0 16.3 15.5 07/12/2005 23:30:00 4.6 0.8 7.2 2.3 4.5 0.8 6.8 2.3 3.5 1 6.1 1.5 22 13 21 255 15.3 0.2 16 14.9 07/12/2005 23:40:00 4.3 0.8 7.2 2.6 4.3 0.8 7.6 2.3 3.3 1 6.1 0.7 23 17 12 255 14.7 0 15.2 14.6 07/12/2005 23:50:00 3.4 1.2 7.6 0.4 3.2 1.2 6.8 0.4 2.4 1.3 7.6 0.4 11 28 349 255 14.4 0 15.2 14.4 07/13/2005 00:00:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.8 3.8 0.4 35 21 22 255 14.7 0 15.2 14.4 07/13/2005 00:10:00 2.9 1 8.4 1.1 2.8 1.1 8.4 0.7 2.4 0.8 6.1 1.1 61 19 65 255 14.6 0.1 15.5 14.6 07/13/2005 00:20:00 5.1 1.7 9.1 1.9 5 1.7 9.1 1.1 4.2 1.5 7.6 0.4 38 19 18 255 14.8 0.2 15.7 14.6 07/13/2005 00:30:00 5.1 1 8 2.3 5 1 8 2.6 4.3 0.9 6.8 2.3 32 13 32 255 15.5 0 16 15.5 07/13/2005 00:40:00 5.3 1.4 8.8 2.3 5.2 1.5 8.8 1.9 4.6 1.2 7.2 1.5 32 17 34 255 15.3 0 15.7 15.2 07/13/2005 00:50:00 5.1 1.2 8.4 2.3 5 1.2 8.8 1.9 3.5 1.2 6.8 1.1 2 17 342 255 14.8 0.2 15.7 14.4 07/13/2005 01:00:00 3.6 0.8 5.7 1.1 3.5 0.9 5.7 0.7 2.4 1 4.9 0.4 11 16 11 255 14.2 0.1 14.9 14.1 07/13/2005 01:10:00 3.8 1.5 6.8 0.4 3.7 1.5 6.8 1.1 3 1.2 6.1 0.4 58 39 357 255 14.3 0 15.2 13.8 07/13/2005 01:20:00 3.1 1 7.2 0.4 3 1 7.6 0.7 2.5 0.9 5.7 0.4 72 24 37 255 14 0.3 14.9 13.5 07/13/2005 01:30:00 3.8 1.3 7.2 1.1 3.6 1.4 7.2 0.7 2.9 1.3 7.2 0.4 45 30 19 255 13.5 0 13.8 13.3 07/13/2005 01:40:00 3 1 4.9 0.7 3 1 5.3 0.4 2.4 1 4.9 0.4 75 22 68 255 13 0.2 13.5 12.7 07/13/2005 01:50:00 2.6 0.5 4.2 1.5 2.4 0.6 4.2 1.1 1.8 0.5 3.4 0.4 97 10 64 255 12.4 0.1 13 12.2 07/13/2005 02:00:00 3.1 0.6 4.9 1.9 3 0.6 4.6 1.5 2.3 0.6 3.8 1.1 102 11 93 255 11.8 0.1 12.2 11.7 07/13/2005 02:10:00 2.8 0.8 4.9 1.1 2.6 0.9 4.9 0.4 2 0.8 4.6 0.4 113 12 128 255 11.7 0 12.2 11.7 07/13/2005 02:20:00 3.8 1 6.8 1.5 3.7 1 6.1 1.5 2.9 0.8 4.9 1.5 111 13 86 255 11.8 0 12.2 11.7 07/13/2005 02:30:00 4.1 0.7 6.5 1.9 4 0.8 6.8 1.5 3.1 0.8 4.9 1.1 95 13 88 255 12.4 0.1 13 11.9 07/13/2005 02:40:00 4.6 0.8 6.8 2.3 4.5 0.9 6.5 1.5 3.4 0.9 5.3 1.1 86 12 97 255 12.7 0 13 12.5 07/13/2005 02:50:00 4.9 0.7 6.5 3 5 0.8 6.8 2.6 3.8 0.9 5.7 1.5 74 12 73 255 12.9 0 13.3 12.7 07/13/2005 03:00:00 5.2 0.6 6.8 3.8 5.2 0.6 6.8 3.4 4 0.9 6.5 1.9 79 11 86 255 12.8 0 13.3 12.7 07/13/2005 03:10:00 4.6 0.8 6.5 2.6 4.6 0.9 6.5 2.6 3.7 1 6.1 0.7 88 11 80 255 12.9 0 13.3 12.7 07/13/2005 03:20:00 4.5 0.6 6.5 2.3 4.5 0.6 6.5 2.6 3.6 0.8 5.3 1.5 92 10 89 255 12.8 0 13.3 12.7 07/13/2005 03:30:00 5 0.6 6.8 3 4.9 0.6 6.5 3 3.9 0.8 6.1 2.3 95 9 90 255 12.8 0 13 12.7 07/13/2005 03:40:00 5 0.6 6.8 3 4.9 0.6 6.8 3.4 4 0.7 5.7 2.3 95 10 93 255 12.7 0 12.7 12.5 07/13/2005 03:50:00 4.7 0.7 6.5 2.6 4.6 0.7 6.5 2.3 3.6 0.8 5.7 1.5 98 9 105 255 12.7 0 12.7 12.5 07/13/2005 04:00:00 4.4 0.6 6.5 2.6 4.3 0.6 5.7 2.3 3.2 0.7 4.9 1.5 93 11 89 255 12.7 0 12.7 12.5 07/13/2005 04:10:00 4.6 0.7 6.5 3 4.5 0.7 6.5 2.6 3.6 0.7 4.9 1.9 88 11 101 255 12.8 0 12.7 12.7 07/13/2005 04:20:00 4.5 0.6 6.1 2.6 4.4 0.6 5.7 2.6 3.4 0.7 4.9 1.1 91 9 83 255 12.7 0 12.7 12.7 07/13/2005 04:30:00 4.3 0.6 6.1 3 4.2 0.5 5.7 3 3.4 0.6 5.3 1.9 97 9 81 255 12.6 0 12.7 12.5 07/13/2005 04:40:00 5.2 0.7 6.8 3 5.1 0.8 6.8 3 4.1 0.7 5.7 2.3 102 10 106 255 12.8 0.1 13 12.5 07/13/2005 04:50:00 5.6 0.8 7.6 3.8 5.5 0.7 7.6 3.8 4.5 0.9 6.5 2.3 98 11 94 255 13.1 0 13.3 13 07/13/2005 05:00:00 4.7 0.7 6.5 2.6 4.6 0.7 6.5 2.6 3.7 0.8 6.5 1.5 94 11 106 255 13.6 0.1 14.1 13.3 07/13/2005 05:10:00 4.4 0.7 6.5 1.9 4.4 0.8 5.7 1.9 3.5 0.8 5.3 1.5 83 14 78 255 14.6 0.3 15.5 14.1 07/13/2005 05:20:00 4.6 0.8 6.5 2.6 4.6 0.8 6.5 2.3 3.7 1 6.1 1.5 81 13 58 255 14.8 0.2 15.2 14.6 07/13/2005 05:30:00 3.8 0.7 5.7 1.9 3.7 0.6 5.7 1.9 3.1 0.7 4.9 0.7 80 12 93 255 14.7 0 15.5 14.6 07/13/2005 05:40:00 4 0.8 6.5 2.3 3.9 0.8 6.1 1.9 2.9 0.8 4.9 1.1 80 13 59 255 14.9 0.1 15.7 14.6 07/13/2005 05:50:00 3.8 0.6 5.7 2.3 3.7 0.6 5.3 2.3 3.2 0.7 4.9 1.5 95 13 101 255 14.5 0 15.2 14.4 07/13/2005 06:00:00 3.6 0.5 5.3 2.3 3.5 0.6 4.9 2.3 2.9 0.6 4.6 1.5 88 11 96 255 14.8 0.2 15.7 14.4 07/13/2005 06:10:00 3.9 0.7 6.1 1.9 3.8 0.7 6.5 1.9 3.2 0.7 5.3 1.5 92 15 92 255 15 0 15.7 14.9 07/13/2005 06:20:00 4.2 1 8 1.9 4.1 1 7.6 1.5 3.4 1 6.1 1.1 83 12 74 255 14.9 0.2 15.7 14.6 07/13/2005 06:30:00 4.4 0.8 6.1 2.3 4.3 0.9 6.5 1.5 3.5 1 5.3 0.7 94 15 74 255 15.6 0.2 16.3 15.2 07/13/2005 06:40:00 3.8 0.8 5.7 1.9 3.8 0.8 5.7 1.5 3.2 0.9 5.7 0.7 85 14 82 255 16.2 0.2 16.8 16 07/13/2005 06:50:00 3.8 1 6.5 1.9 3.7 1 6.8 1.5 3 0.9 5.7 0.7 82 16 88 255 15.8 0.2 16.3 15.5 07/13/2005 07:00:00 4.3 1 7.2 2.3 4.3 1 6.8 1.9 3.7 1 6.1 1.1 72 14 80 255 16.2 0.2 16.8 15.7 07/13/2005 07:10:00 3.7 0.7 6.1 1.9 3.5 0.7 6.1 1.5 2.8 1 5.7 0.4 81 14 63 255 15.6 0 16.3 15.5 07/13/2005 07:20:00 3.3 1.1 5.7 1.5 3.1 1.2 5.7 0.7 2.6 1 5.7 0.4 77 15 71 255 15.6 0 16.3 15.5 07/13/2005 07:30:00 3.2 0.8 5.3 1.1 3 0.9 4.9 0.7 2.6 0.8 4.9 1.1 77 18 94 255 15.7 0.1 16.3 15.7 07/13/2005 07:40:00 3.1 0.8 4.9 1.5 3 0.8 4.9 1.1 2.5 0.9 4.9 0.7 81 15 82 255 16.8 0.2 17.4 16.3 07/13/2005 07:50:00 4 1.3 8 1.5 3.8 1.4 7.6 0.7 3 1.2 6.1 0.4 72 21 27 255 16.7 0 17.1 16.8 07/13/2005 08:00:00 4 0.9 6.5 1.9 3.9 0.9 6.5 1.5 3.3 1 5.3 0.7 59 19 51 255 17.3 0.2 17.7 16.8 07/13/2005 08:10:00 3.6 1 5.7 0.7 3.5 1 6.1 0.4 3 1.2 6.1 0.4 66 20 18 255 17.5 0 17.7 17.1 07/13/2005 08:20:00 4.2 1.5 7.6 1.1 4.1 1.6 7.6 1.1 3.6 1.3 6.8 0.7 52 18 32 255 17.5 0 17.7 17.4 07/13/2005 08:30:00 5.1 1 8 2.3 5.1 1.1 8 2.6 4.3 1 7.2 1.9 56 17 36 255 17.9 0.2 18.8 17.4 07/13/2005 08:40:00 5.1 1.3 8 1.1 4.9 1.4 8 1.5 4.1 1.4 8 0.7 54 21 55 255 18.7 0.1 19.1 18.5 07/13/2005 08:50:00 5.2 1.4 8.8 1.9 5.1 1.5 8.4 1.1 4.1 1.3 8 1.5 62 23 33 255 19.2 0.4 20 18.2 07/13/2005 09:00:00 5.4 1.7 9.1 1.9 5.3 1.7 9.5 1.9 4.4 1.5 8.4 1.1 36 18 13 255 20 0.2 20.8 19.7 07/13/2005 09:10:00 5.3 1.6 8.4 1.5 5.2 1.7 8 1.1 4.4 1.7 8.4 0.7 43 22 35 255 20 0.4 20.8 19.1 07/13/2005 09:20:00 5.4 1.6 8.8 1.9 5.3 1.6 8.8 1.5 4.3 1.3 7.6 1.1 44 21 58 255 19.5 0.4 20.5 18.8 07/13/2005 09:30:00 5.6 0.9 7.6 2.6 5.5 1 7.6 3 4.8 1 7.2 2.3 40 16 59 255 20.3 0.2 21.1 20 07/13/2005 09:40:00 6.1 1.2 9.5 2.6 6 1.2 9.9 2.6 5 1.3 8.4 1.9 40 15 61 255 20.8 0 21.1 20.5 07/13/2005 09:50:00 6.6 1.4 11.1 3.4 6.6 1.5 11.1 3.4 5.6 1.5 9.9 2.6 36 18 19 255 21 0 21.4 20.8 07/13/2005 10:00:00 5.8 1.3 9.9 2.3 5.7 1.3 9.9 1.9 4.8 1.4 9.5 1.1 40 21 53 255 21.3 0.1 21.7 21.1 07/13/2005 10:10:00 6 1.5 9.9 1.5 5.9 1.4 9.5 1.1 5.2 1.6 9.1 0.7 42 20 35 255 21.6 0 22.3 21.1 07/13/2005 10:20:00 6.9 1.5 10.7 2.6 6.8 1.5 11.1 3.4 5.6 1.5 10.3 2.3 34 18 25 255 21.5 0 22 21.1 07/13/2005 10:30:00 6.6 1.7 11.5 3.4 6.6 1.7 11.5 3.4 4.9 1.8 11.1 1.5 22 15 6 255 21.9 0.3 22.9 21.1 07/13/2005 10:40:00 6.4 1.3 9.5 3 6.3 1.3 9.9 2.6 5.3 1.4 9.5 2.3 30 18 27 255 22.6 0 22.9 22.3 07/13/2005 10:50:00 7.5 1.3 10.3 4.6 7.4 1.3 10.7 4.6 6.2 1.3 9.9 3.8 37 11 59 255 22.1 0 22.3 22 07/13/2005 11:00:00 7 1.3 9.9 3.8 6.9 1.3 9.9 4.2 5.6 1.5 9.9 2.3 27 16 26 255 22.3 0 22.9 22 07/13/2005 11:10:00 7.4 1.4 11.1 3 7.4 1.4 10.7 3 6.2 1.2 9.1 2.6 33 14 30 255 22.6 0 23.5 22.3 07/13/2005 11:20:00 6.7 1.5 9.9 3 6.6 1.5 9.9 3.4 5.6 1.5 9.5 2.3 41 17 56 255 22.5 0 23.2 22.3 07/13/2005 11:30:00 6.4 1.7 10.7 2.3 6.3 1.7 10.7 2.3 5.4 1.6 9.9 1.9 50 17 52 255 22.7 0 23.2 22.6 07/13/2005 11:40:00 7.7 1.5 11.5 3.8 7.6 1.5 11.5 3 6.5 1.7 10.7 2.6 40 16 41 255 22.3 0 22.9 22.3 07/13/2005 11:50:00 7.6 1.6 12.6 4.2 7.6 1.6 12.2 3.8 6.1 1.8 13 1.1 26 20 42 255 23 0.1 23.5 22.6 07/13/2005 12:00:00 8.7 1.7 13.3 4.6 8.6 1.8 13.3 4.2 6.6 2.2 11.5 1.5 20 14 7 255 23.3 0.1 23.8 22.9 07/13/2005 12:10:00 7.6 1.8 12.6 3.4 7.5 1.9 12.6 3 5.7 2 11.5 1.5 12 16 4 255 23.8 0.2 24.4 23.5 07/13/2005 12:20:00 8 1.5 11.8 3.8 8 1.5 11.5 4.2 5.8 1.9 9.5 1.5 14 16 20 255 23.2 0.6 24.1 22.3 07/13/2005 12:30:00 7.1 1.3 11.1 3.4 7 1.4 11.1 3.8 5.8 1.7 9.9 1.5 20 16 20 255 23 0.4 23.8 22.3 07/13/2005 12:40:00 8.5 1.8 12.2 3.4 8.4 1.9 12.2 3 6.4 2.3 11.1 1.1 11 15 11 255 23.5 0.5 25 22.9 07/13/2005 12:50:00 7.6 1.6 11.1 3 7.5 1.7 11.5 2.6 5.6 1.9 9.9 1.1 10 16 18 255 24.5 0.1 25.3 24.1 07/13/2005 13:00:00 7.3 1.7 11.5 2.6 7.3 1.8 11.5 2.3 5.3 1.8 9.9 1.5 12 17 24 255 24.7 0 25 24.4 07/13/2005 13:10:00 8.1 1.5 12.6 4.6 8.1 1.5 12.6 4.6 6.8 1.7 11.1 2.6 21 12 10 255 23.1 0.7 24.4 22 07/13/2005 13:20:00 8.2 1.5 11.8 4.6 8.1 1.5 12.2 4.6 6.2 1.7 11.1 1.5 25 17 14 255 22.7 0.6 24.1 22 07/13/2005 13:30:00 9.4 1.7 13 4.6 9.3 1.7 13 4.6 7.4 2.2 13 2.6 21 12 7 255 23.8 0.2 24.7 23.5 07/13/2005 13:40:00 8.6 1.6 13.3 5.3 8.6 1.6 13.7 4.9 7 1.8 12.6 3.4 24 15 23 255 24.2 0.4 25 23.5 07/13/2005 13:50:00 8.5 1.7 11.8 2.6 8.4 1.7 12.2 1.9 7.2 1.9 11.5 1.1 25 15 35 255 24.3 0.4 25 23.8 07/13/2005 14:00:00 8 1.6 11.5 3.8 7.9 1.6 11.8 4.2 6.8 1.7 10.7 2.6 30 14 26 255 24.5 0.4 25.3 23.8 07/13/2005 14:10:00 8 1.6 11.5 4.2 8 1.6 11.5 4.2 6.8 1.7 11.1 2.3 30 17 37 255 25.1 0 25.3 25 07/13/2005 14:20:00 8.2 1.5 11.8 4.6 8.1 1.5 11.8 4.9 6.3 1.6 10.7 3 23 15 28 255 23.9 1 25.3 22.6 07/13/2005 14:30:00 7.6 1.5 12.2 3.8 7.5 1.5 12.2 4.2 5.7 1.7 10.3 1.9 15 13 11 255 21.7 0.4 22.6 21.1 07/13/2005 14:40:00 7.7 1.7 11.5 2.3 7.6 1.7 11.5 2.3 6 2.1 10.3 1.1 21 17 19 255 21.8 0.7 23.5 21.1 07/13/2005 14:50:00 8.6 1.4 12.2 4.9 8.6 1.5 11.8 4.6 7.1 1.6 11.1 3.4 28 13 31 255 23.8 0.2 24.4 23.2 07/13/2005 15:00:00 8.1 1.5 11.5 4.2 8 1.5 11.5 3.4 6.7 1.5 10.3 2.6 26 15 17 255 24.1 0.2 25 23.8 07/13/2005 15:10:00 7.4 1.3 11.1 4.6 7.3 1.3 11.5 4.6 6.1 1.5 10.7 3 31 13 31 255 22.4 0.6 23.8 21.7 07/13/2005 15:20:00 8.1 2 13.3 4.2 8.1 2 13.3 4.2 6.5 2.4 11.8 2.3 24 15 32 255 22.3 0.1 22.9 22 07/13/2005 15:30:00 9 1.7 13 2.6 9 1.8 13 2.6 6.9 2 11.8 1.5 17 15 21 255 23.3 0.4 24.4 22.6 07/13/2005 15:40:00 8.7 1.6 13 5.3 8.7 1.6 12.6 4.9 7.5 1.6 11.5 3 25 13 16 255 24 0.1 24.7 23.8 07/13/2005 15:50:00 9.3 1.5 13 5.3 9.2 1.5 12.6 4.9 7.8 1.6 11.8 3.8 29 13 30 255 23.8 0 24.1 23.8 07/13/2005 16:00:00 8.3 1.8 13.3 4.6 8.3 1.8 13.3 4.6 6.9 2 13 1.9 28 14 38 255 23.9 0 24.1 23.8 07/13/2005 16:10:00 8.1 1.6 12.6 3.4 8 1.6 12.2 3.4 6.4 1.8 11.1 2.3 24 14 22 255 24.1 0.2 24.4 23.5 07/13/2005 16:20:00 8.9 1.7 13.3 4.2 8.9 1.8 13.3 3.4 7.1 2 13.3 2.6 23 13 27 255 23.8 0 24.1 23.5 07/13/2005 16:30:00 8.4 1.8 12.6 3.8 8.4 1.8 12.6 3 7 1.8 11.1 3 21 14 13 255 24.1 0 24.4 24.1 07/13/2005 16:40:00 7.6 1.8 10.7 3 7.6 1.9 11.1 2.3 6.1 1.9 9.5 1.1 18 17 63 255 23.9 0.1 24.4 23.8 07/13/2005 16:50:00 8.4 1.6 12.6 4.2 8.3 1.6 12.6 3.4 6.9 1.8 11.1 3 23 14 9 255 23.8 0 24.1 23.8 07/13/2005 17:00:00 8.4 1.7 12.6 4.6 8.4 1.7 13 4.6 6.5 1.8 11.8 3 21 13 0 255 23.6 0 23.8 23.5 07/13/2005 17:10:00 7.8 1.4 13 4.2 7.8 1.4 12.6 4.2 6.2 1.7 10.7 2.6 18 14 6 255 22.4 0.4 23.5 21.7 07/13/2005 17:20:00 8 1.7 12.6 3.8 7.9 1.7 12.6 2.6 6.4 2 10.7 1.5 20 16 352 255 21.5 0.1 22 21.1 07/13/2005 17:30:00 8 1.8 12.6 3.8 7.9 1.9 12.6 3.4 6.3 2.2 11.5 1.9 21 16 31 255 20.8 0.1 21.4 20.8 07/13/2005 17:40:00 8 1.5 11.8 4.2 7.9 1.6 11.8 4.6 6 1.7 9.9 2.3 18 14 47 255 20.8 0 21.1 20.8 07/13/2005 17:50:00 7.6 1.7 11.8 3 7.5 1.7 11.5 2.3 5.5 1.7 9.9 1.1 15 15 31 255 21.1 0 21.1 21.1 07/13/2005 18:00:00 8.6 1.8 12.6 3.4 8.6 1.8 12.2 3.8 6.8 2.1 11.5 2.6 19 15 22 255 20.7 0.2 21.1 20.5 07/13/2005 18:10:00 8.8 1.4 12.2 4.6 8.7 1.4 11.8 3.8 7 1.7 11.5 2.6 21 13 21 255 21.2 0.4 21.7 20.5 07/13/2005 18:20:00 8.5 1.7 14.1 4.9 8.5 1.7 14.9 4.9 6.6 1.9 13 2.6 16 14 22 255 21.6 0 22 21.1 07/13/2005 18:30:00 8.4 1.9 13 4.2 8.4 1.9 13.3 3.8 6.7 1.9 11.5 2.3 18 15 25 255 20.7 0.2 21.1 20.3 07/13/2005 18:40:00 8 2 12.6 3.4 7.9 2 12.2 3.8 6.5 1.9 11.8 2.3 20 16 19 255 20.4 0 20.8 20.3 07/13/2005 18:50:00 8 1.4 11.5 4.9 7.9 1.5 11.5 4.2 6.4 1.7 10.7 2.3 22 17 5 255 20.8 0.2 21.1 20.5 07/13/2005 19:00:00 8 1.4 11.5 4.6 7.9 1.4 11.5 4.2 6.3 1.5 10.7 2.3 18 14 27 255 20.3 0.2 20.8 19.7 07/13/2005 19:10:00 7 2 12.2 3.4 7 2 11.8 3 5.5 2 10.7 1.5 18 15 32 255 19.6 0.2 20.3 19.4 07/13/2005 19:20:00 7.2 2.1 11.8 2.3 7.2 2.1 11.8 2.6 5.7 1.9 9.9 1.9 20 16 17 255 19.3 0.2 20 19.1 07/13/2005 19:30:00 7.1 1.3 10.7 3.4 7 1.3 10.3 3.4 5.7 1.4 9.9 2.3 21 14 12 255 19 0 19.4 18.8 07/13/2005 19:40:00 7 1.7 11.5 2.3 6.9 1.8 11.5 2.3 5.5 1.5 9.5 1.5 21 14 4 255 18.8 0 19.4 18.5 07/13/2005 19:50:00 6.8 1.3 9.5 2.3 6.8 1.2 9.5 2.6 5.4 1.4 8 1.5 19 11 39 255 18.6 0 19.1 18.5 07/13/2005 20:00:00 5.8 1.2 8.4 2.3 5.8 1.2 8.8 2.3 4.5 1.5 8.4 1.1 16 12 30 255 18.5 0 19.1 18.2 07/13/2005 20:10:00 5.1 0.9 8.4 3 5.1 0.9 8 3 3.8 1.2 8 1.1 18 13 37 255 18.3 0 18.5 18.2 07/13/2005 20:20:00 5 1.1 8 2.3 5 1.1 8 1.9 3.9 1.3 7.2 1.1 16 12 22 255 18.2 0 18.2 18 07/13/2005 20:30:00 4.5 0.9 6.8 2.6 4.6 0.9 6.8 2.6 3.6 1 6.5 1.5 15 8 37 255 18 0 18.2 18 07/13/2005 20:40:00 4.2 1.2 6.8 1.5 4.2 1.2 6.5 1.5 2.8 1.1 5.7 0.4 12 15 27 255 17.8 0 18 17.7 07/13/2005 20:50:00 5.1 0.9 7.2 2.6 5 0.9 7.2 3 3.5 1.3 6.8 0.7 10 12 7 255 17.6 0 17.7 17.4 07/13/2005 21:00:00 3.2 0.7 5.3 1.5 3.1 0.7 5.3 1.1 1.9 0.8 4.2 0.4 0 13 18 255 17.3 0 17.7 17.1 07/13/2005 21:10:00 2.8 0.5 3.8 1.5 2.8 0.5 3.8 1.1 1.4 0.7 3 0.4 3 9 358 255 17.1 0 17.1 16.8 07/13/2005 21:20:00 2.1 0.5 3 1.1 2.1 0.5 3 1.1 0.9 0.6 2.6 0.4 6 10 4 255 16.7 0 16.8 16.6 07/13/2005 21:30:00 2.1 0.4 3 0.7 2.1 0.4 3 0.7 1 0.6 2.6 0.4 10 9 15 255 16.4 0.1 16.8 16.3 07/13/2005 21:40:00 1.8 0.4 2.6 0.7 1.8 0.3 2.3 0.7 0.8 0.5 2.3 0.4 13 12 6 255 15.9 0 16.3 15.7 07/13/2005 21:50:00 1.8 0.4 3 0.7 1.7 0.4 2.6 0.4 0.5 0.3 1.5 0.4 9 9 3 255 15.3 0.1 15.7 15.2 07/13/2005 22:00:00 2.1 0.6 3.4 0.7 2.1 0.6 3.4 0.7 1.1 0.6 3 0.4 10 10 4 255 14.8 0 15.5 14.6 07/13/2005 22:10:00 2.1 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.1 0.6 3 0.4 8 10 16 255 14.4 0 15.2 14.1 07/13/2005 22:20:00 2.5 0.9 4.6 0.7 2.5 0.9 4.6 0.7 1.2 0.8 4.2 0.4 14 15 13 255 14 0 14.6 13.5 07/13/2005 22:30:00 1.6 0.4 2.6 0.7 1.6 0.4 3 0.7 0.7 0.4 1.9 0.4 1 11 18 255 13.6 0 14.1 13.5 07/13/2005 22:40:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.5 0.3 1.9 0.4 24 15 15 255 13.5 0.1 13.8 13 07/13/2005 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 40 255 13.1 0.2 13.5 12.7 07/13/2005 23:00:00 1.6 0.6 3.4 0.4 1.5 0.6 3 0.4 1 0.5 2.3 0.4 30 13 5 255 12.6 0.1 13.3 12.2 07/13/2005 23:10:00 1.4 0.3 2.6 0.7 1.3 0.4 2.3 0.7 0.6 0.3 1.9 0.4 35 12 24 255 12.3 0 12.7 12.2 07/13/2005 23:20:00 1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 48 9 17 255 12.2 0 12.7 12.2 07/13/2005 23:30:00 1.6 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.5 0.2 1.9 0.7 73 5 74 255 12.3 0 12.7 12.2 07/13/2005 23:40:00 2.2 0.3 3 1.5 2.2 0.3 2.6 1.5 1.4 0.4 2.3 0.4 90 5 93 255 12.3 0 12.7 12.2 07/13/2005 23:50:00 2.2 0.3 3.4 1.5 2.2 0.3 3 1.5 1.4 0.4 2.3 0.4 100 9 107 255 12.3 0 12.7 12.2 07/14/2005 00:00:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.5 0.5 3 0.4 100 16 87 255 12.1 0 12.5 11.9 07/14/2005 00:10:00 2.3 0.4 3 1.1 2.2 0.4 3.4 1.1 1.2 0.5 2.3 0.4 76 15 53 255 12.2 0 12.2 11.9 07/14/2005 00:20:00 2.4 0.6 4.2 0.7 2.4 0.7 4.2 0.7 1.5 0.6 3 0.4 57 13 67 255 12.1 0 12.5 11.9 07/14/2005 00:30:00 2.7 0.5 4.2 1.1 2.7 0.5 4.2 1.5 2 0.6 3.8 0.7 43 13 35 255 12.7 0.3 13.5 12.2 07/14/2005 00:40:00 3.1 0.7 4.9 1.1 3.1 0.7 4.9 1.5 2.3 0.7 5.3 1.1 39 13 45 255 13.3 0 13.8 13 07/14/2005 00:50:00 2.2 0.8 4.6 0.7 2.2 0.8 4.2 0.4 1.7 0.7 4.2 0.7 43 26 30 255 13.1 0.2 13.8 12.7 07/14/2005 01:00:00 2.7 0.6 4.6 1.5 2.7 0.6 4.6 1.1 2.2 0.5 3.8 1.1 58 15 46 255 12.9 0.1 13.3 12.7 07/14/2005 01:10:00 3.3 0.5 4.6 1.9 3.4 0.5 4.6 1.9 2.5 0.6 3.8 1.1 65 8 51 255 13.1 0 13.3 13 07/14/2005 01:20:00 2.7 0.4 3.8 1.9 2.8 0.4 3.8 1.9 1.9 0.5 3 0.7 76 11 86 255 12.9 0 13 12.5 07/14/2005 01:30:00 1.6 0.7 3.4 0.4 1.5 0.8 3.8 0.4 1 0.7 3 0.4 75 20 58 255 12.4 0 12.7 11.9 07/14/2005 01:40:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 112 5 113 255 11.8 0.1 12.5 11.7 07/14/2005 01:50:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 126 9 100 255 11.3 0 11.9 11.1 07/14/2005 02:00:00 1.3 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 141 11 146 255 10.7 0.1 11.4 10.6 07/14/2005 02:10:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.4 1.4 0.4 2.3 0.4 128 14 112 255 10.2 0 10.6 9.8 07/14/2005 02:20:00 2 0.5 3 0.7 1.9 0.4 3.4 0.7 1.4 0.4 2.6 0.4 113 11 109 255 9.7 0.1 10.1 9.6 07/14/2005 02:30:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.1 0.4 2.6 0.4 115 11 110 255 9.5 0 9.6 9.6 07/14/2005 02:40:00 2.1 0.3 3 1.1 2.1 0.3 3 1.1 1.8 0.4 2.6 0.7 140 12 146 255 9.2 0.1 9.6 9 07/14/2005 02:50:00 1.9 0.4 3 0.4 1.8 0.5 2.6 0.4 1.3 0.4 2.3 0.4 125 15 135 255 8.9 0 9 8.8 07/14/2005 03:00:00 2 0.4 3 1.1 1.9 0.4 2.6 0.7 0.9 0.4 1.9 0.4 107 11 106 255 8.9 0 9 8.8 07/14/2005 03:10:00 2.3 0.5 3.4 1.1 2.3 0.5 3.8 1.1 1.2 0.5 2.6 0.4 68 26 88 255 8.7 0 8.8 8.5 07/14/2005 03:20:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.4 0.4 2.3 0.4 38 9 30 255 8.5 0 8.8 8.5 07/14/2005 03:30:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 45 12 34 255 8.4 0 8.5 8.3 07/14/2005 03:40:00 1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.5 0.2 1.1 0.4 69 12 20 255 8.3 0 8.5 8.3 07/14/2005 03:50:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 1.2 0.3 1.9 0.4 91 8 84 255 8.3 0 8.5 8.3 07/14/2005 04:00:00 2 0.2 2.6 1.1 2 0.3 2.6 1.1 0.9 0.4 1.9 0.4 85 12 97 255 8.1 0 8.3 8 07/14/2005 04:10:00 1.8 0.3 2.6 1.1 1.7 0.3 2.3 0.7 0.5 0.2 1.1 0.4 84 15 105 255 8.1 0 8.3 8 07/14/2005 04:20:00 2.2 0.3 2.6 1.5 2.2 0.3 3 1.5 1 0.5 1.9 0.4 100 6 91 255 8.1 0 8.3 8.3 07/14/2005 04:30:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.7 0.4 2.6 0.7 101 5 105 255 8.1 0.1 8.3 8 07/14/2005 04:40:00 2.1 0.4 3 1.1 2 0.4 3 0.7 0.9 0.4 1.9 0.4 108 12 99 255 8.1 0 8.3 8 07/14/2005 04:50:00 1.8 0.4 2.6 0.7 1.8 0.5 3 0.7 1.4 0.5 2.6 0.4 127 13 121 255 8.4 0 8.8 8.3 07/14/2005 05:00:00 2.1 0.5 3.4 1.1 2.1 0.5 3.4 0.4 1.3 0.5 2.6 0.4 116 13 104 255 9.2 0.3 9.8 8.8 07/14/2005 05:10:00 2 0.6 3.8 0.4 1.9 0.6 3.8 0.4 1.2 0.6 3 0.4 115 15 117 255 10 0 10.1 9.8 07/14/2005 05:20:00 1.5 0.4 2.3 0.4 1.4 0.4 2.6 0.4 0.6 0.4 2.3 0.4 108 14 127 255 9.9 0 10.1 9.6 07/14/2005 05:30:00 2.6 0.4 3.4 1.5 2.5 0.5 3.4 1.1 1.6 0.6 3 0.4 108 9 105 255 9.8 0 10.1 9.6 07/14/2005 05:40:00 2.1 0.5 3 0.4 2.1 0.5 3 0.4 1.4 0.5 2.6 0.4 115 13 123 255 10.8 0.4 11.7 10.1 07/14/2005 05:50:00 1.8 0.4 3 0.7 1.7 0.5 2.6 0.4 1.1 0.4 2.3 0.4 108 9 102 255 11.7 0 11.9 11.7 07/14/2005 06:00:00 1.7 0.5 3 0.7 1.6 0.6 3 0.4 1.1 0.5 2.6 0.4 105 9 100 255 11.7 0.2 12.2 11.4 07/14/2005 06:10:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.5 0.4 71 13 79 255 12.4 0 12.7 12.2 07/14/2005 06:20:00 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 78 6 69 255 11.9 0.2 12.7 11.7 07/14/2005 06:30:00 1.4 0.7 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 60 13 86 255 13.9 0.6 14.9 12.7 07/14/2005 06:40:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 60 21 73 255 15.5 0.4 16.3 14.9 07/14/2005 06:50:00 1.5 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 46 14 56 255 16.7 0 17.1 16.3 07/14/2005 07:00:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 1.1 1.7 0.3 2.6 0.4 47 15 62 255 16.3 0.1 16.8 16 07/14/2005 07:10:00 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 63 22 81 255 15.9 0 16.3 15.5 07/14/2005 07:20:00 1.7 0.5 3 0.4 1.7 0.6 3 0.4 1.4 0.6 3 0.4 75 9 80 255 14.9 0.2 15.7 14.6 07/14/2005 07:30:00 1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.9 0.4 72 5 69 255 14.2 0.2 14.9 13.8 07/14/2005 07:40:00 1.2 0.4 1.9 0.4 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 82 13 74 255 13.9 0 14.4 13.8 07/14/2005 07:50:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.7 0.5 1.9 0.4 92 6 104 255 13.9 0 14.4 13.8 07/14/2005 08:00:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 106 13 104 255 14.2 0.1 14.6 13.8 07/14/2005 08:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.8 0.4 2.3 0.4 65 16 72 255 14.2 0 14.9 14.1 07/14/2005 08:20:00 1.3 0.3 1.9 0.4 1.2 0.4 1.9 0.4 1.1 0.4 2.3 0.4 52 12 48 255 14.5 0 14.9 14.4 07/14/2005 08:30:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 39 13 13 255 14.8 0 15.5 14.6 07/14/2005 08:40:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 42 20 31 255 15 0 15.7 14.9 07/14/2005 08:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 38 27 6 255 15.4 0 15.7 15.2 07/14/2005 09:00:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 33 82 326 255 15.9 0.3 16.6 15.5 07/14/2005 09:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 347 27 321 255 16.9 0.2 17.4 16.6 07/14/2005 09:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 72 76 74 255 17.2 0 17.4 17.1 07/14/2005 09:30:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0 17 351 255 17 0.1 17.1 16.8 07/14/2005 09:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 41 26 25 255 17.2 0.1 17.7 16.8 07/14/2005 09:50:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1 0.5 2.6 0.4 45 23 13 255 18.3 0.3 18.8 17.7 07/14/2005 10:00:00 1.1 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 29 27 14 255 19.2 0.4 20.3 18.5 07/14/2005 10:10:00 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 2 22 19 255 19.8 0.2 20.3 19.4 07/14/2005 10:20:00 1.3 0.8 3 0.4 1.2 0.7 3 0.4 1 0.7 3 0.4 321 29 326 255 19.2 0.4 20 18.5 07/14/2005 10:30:00 2.4 0.6 3.8 0.4 2.3 0.7 3.8 0.4 1.8 0.8 3.8 0.4 319 21 296 255 18.2 0.2 18.8 17.4 07/14/2005 10:40:00 2.3 0.4 3.8 1.1 2.3 0.4 3.8 1.1 2 0.6 3.4 0.4 308 15 307 255 18.2 0.2 18.8 17.4 07/14/2005 10:50:00 1.6 0.6 3 0.4 1.6 0.6 3.4 0.4 1.3 0.6 2.6 0.4 307 19 304 255 19.5 0.5 20.5 18.2 07/14/2005 11:00:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 3 0.4 301 28 302 255 20.3 0 20.8 20 07/14/2005 11:10:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 1 0.7 3 0.4 330 27 329 255 21.1 0.3 21.7 20.5 07/14/2005 11:20:00 1.4 0.6 2.6 0.4 1.3 0.6 3 0.4 1.3 0.8 3 0.4 318 29 328 255 20.7 0.4 21.1 19.7 07/14/2005 11:30:00 1.3 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.9 0.6 2.6 0.4 278 30 253 255 19.4 0 20 19.1 07/14/2005 11:40:00 2.2 0.4 3.4 1.1 2.1 0.5 3.4 0.7 1.8 0.6 3 0.4 303 18 317 255 19.3 0 19.7 19.1 07/14/2005 11:50:00 2 0.6 3.8 0.4 2 0.6 3.8 0.4 1.9 0.7 3.4 0.4 320 49 273 255 20.6 0.5 21.4 19.7 07/14/2005 12:00:00 2.6 1 4.9 0.4 2.5 1 4.9 0.4 2.3 0.9 4.6 0.4 312 19 317 255 21.8 0.1 22 21.4 07/14/2005 12:10:00 1.5 0.9 3.8 0.4 1.5 0.9 3.8 0.4 1.3 0.8 3.4 0.4 265 64 270 255 21.9 0 22.3 21.7 07/14/2005 12:20:00 1.3 0.7 3.8 0.4 1.3 0.8 4.2 0.4 1.1 0.8 3.8 0.4 258 58 279 255 22.2 0 22.9 22 07/14/2005 12:30:00 2.5 1.2 4.9 0.4 2.5 1.3 4.9 0.4 2.2 1.2 4.6 0.4 300 72 307 255 22.4 0 22.9 22 07/14/2005 12:40:00 2.3 1 4.9 0.4 2.3 1 4.9 0.4 2 1 4.9 0.4 285 30 294 255 22.1 0 22.9 21.7 07/14/2005 12:50:00 1.3 0.7 3.8 0.4 1.2 0.7 3 0.4 0.9 0.6 3 0.4 272 76 289 255 23 0.2 23.5 22.3 07/14/2005 13:00:00 2.3 1 4.9 0.4 2.2 1 4.6 0.4 1.9 1 4.6 0.4 274 38 324 255 23.5 0.2 23.8 22.9 07/14/2005 13:10:00 2.7 1 5.3 0.4 2.6 1.1 6.1 0.4 2.4 1 4.2 0.4 280 33 238 255 22.7 0 22.9 22.6 07/14/2005 13:20:00 2.1 1.1 4.6 0.4 2 1.1 4.6 0.4 1.8 1.1 4.9 0.4 301 30 283 255 23.1 0 23.5 22.9 07/14/2005 13:30:00 2.3 1 4.9 0.4 2.3 1 4.6 0.4 2.2 1.1 4.6 0.4 289 24 306 255 23.7 0.1 24.1 23.5 07/14/2005 13:40:00 1.9 1 4.6 0.4 2 1 4.6 0.4 1.8 0.9 4.6 0.4 256 35 288 255 24.1 0 24.4 23.8 07/14/2005 13:50:00 2.1 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.8 0.9 4.6 0.4 264 28 277 255 24.3 0 24.7 24.1 07/14/2005 14:00:00 2.6 0.9 4.6 0.4 2.6 0.9 4.6 0.7 2.2 0.9 4.2 0.4 284 26 273 255 24.4 0.1 25 24.1 07/14/2005 14:10:00 2.3 0.9 4.6 0.4 2.2 0.8 4.2 0.4 1.8 0.7 3.8 0.4 297 33 312 255 24.8 0 25 24.7 07/14/2005 14:20:00 1.9 1.1 4.6 0.4 1.7 1.1 4.6 0.4 1.4 1.1 5.3 0.4 339 35 340 255 25.2 0.1 25.6 25 07/14/2005 14:30:00 2.4 1 4.9 0.4 2.3 1 4.9 0.4 2 0.9 4.2 0.4 290 43 266 255 25.1 0.1 25.6 25 07/14/2005 14:40:00 3.3 1 5.7 0.7 3.3 1 5.7 0.7 2.8 1.2 5.3 0.7 298 32 255 255 24.8 0.1 25.3 24.7 07/14/2005 14:50:00 3 0.8 4.9 0.4 3 0.8 4.9 0.4 2.6 1 4.2 0.4 302 33 305 255 25.3 0 25.6 25 07/14/2005 15:00:00 2.2 1.1 4.9 0.4 1.9 1.1 4.9 0.4 1.7 1.1 4.6 0.4 334 35 7 255 25.4 0 25.6 25.3 07/14/2005 15:10:00 1 0.7 3 0.4 1 0.7 3 0.4 0.8 0.7 3 0.4 290 58 268 255 25 0.4 25.6 24.1 07/14/2005 15:20:00 2 0.8 3.8 0.4 1.9 0.9 3.8 0.4 1.7 0.9 3.8 0.4 320 29 304 255 24.3 0.3 25.3 23.8 07/14/2005 15:30:00 2.7 0.9 5.3 0.4 2.7 1 5.3 0.4 2.2 0.8 4.2 0.4 287 27 295 255 25.3 0 25.6 25.3 07/14/2005 15:40:00 2.5 0.6 3.8 1.1 2.4 0.6 4.2 1.1 1.8 0.7 3.4 0.4 328 29 328 255 24.8 0.2 25.3 24.4 07/14/2005 15:50:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 1.8 1 3.8 0.4 291 28 293 255 25.6 0.4 26.2 25 07/14/2005 16:00:00 1.9 1 5.7 0.4 1.8 1 5.7 0.4 1.5 0.9 4.6 0.4 309 41 313 255 25.6 0 25.6 25.6 07/14/2005 16:10:00 2.5 1 4.9 0.4 2.4 1 5.3 0.4 1.8 0.9 4.6 0.4 311 28 317 255 25.8 0 26.2 25.6 07/14/2005 16:20:00 3.1 0.5 4.6 1.9 3 0.6 4.6 1.5 2.6 0.7 4.6 0.4 306 22 271 255 25.7 0.3 26.2 25.3 07/14/2005 16:30:00 2.3 1.1 5.7 0.4 2.2 1 5.3 0.4 1.6 0.9 4.9 0.4 311 26 323 255 24.8 0.1 25.3 24.7 07/14/2005 16:40:00 3.3 0.7 5.3 1.9 3.3 0.8 5.3 1.5 2.8 0.9 4.9 0.4 304 19 269 255 24.4 0 25 24.1 07/14/2005 16:50:00 3.4 0.9 5.3 0.7 3.3 0.9 5.3 1.1 2.7 1 5.7 0.4 297 20 268 255 24.7 0 25 24.4 07/14/2005 17:00:00 2.8 1.2 5.3 0.4 2.8 1.1 5.3 0.4 2.1 1 4.6 0.4 271 28 283 255 24.6 0 25 24.4 07/14/2005 17:10:00 3.1 1.2 5.7 0.4 3 1.3 6.1 0.4 2.7 1.2 5.3 0.4 280 27 277 255 24.5 0 25 24.4 07/14/2005 17:20:00 2.5 1 5.3 0.4 2.5 1 5.7 0.4 1.8 0.9 4.2 0.4 257 27 263 255 24.1 0.1 24.4 24.1 07/14/2005 17:30:00 2.6 1.1 5.3 0.4 2.6 1.2 5.3 0.4 1.9 1.1 4.6 0.4 270 33 252 255 23.9 0 24.1 23.8 07/14/2005 17:40:00 3.6 1 6.1 0.7 3.7 1 5.7 0.7 2.8 1.1 5.7 0.4 264 19 253 255 23.6 0 23.8 23.5 07/14/2005 17:50:00 3.2 1 5.7 0.4 3.2 1 5.7 0.7 2.7 1 5.3 0.4 273 24 292 255 23.4 0 23.8 23.5 07/14/2005 18:00:00 2.3 1.1 5.3 0.4 2.3 1.1 5.3 0.4 1.8 1.1 4.6 0.4 271 29 267 255 23.4 0 23.5 23.5 07/14/2005 18:10:00 3.4 1.2 6.1 0.4 3.4 1.2 5.7 0.4 2.7 1.2 6.5 0.4 267 18 267 255 23.4 0 23.8 23.5 07/14/2005 18:20:00 3.4 1.1 5.7 0.4 3.4 1.1 6.1 1.1 2.8 1 5.3 0.4 274 22 255 255 23.2 0 23.5 22.9 07/14/2005 18:30:00 3 1 5.3 0.4 3 1 5.3 0.4 2.3 1 4.6 0.4 277 29 273 255 22.4 0.1 22.9 22 07/14/2005 18:40:00 2.6 0.8 4.2 0.7 2.6 0.8 4.9 0.7 1.8 0.9 4.2 0.4 264 16 265 255 21.7 0.1 22.3 21.4 07/14/2005 18:50:00 2.8 0.9 5.3 0.4 2.8 1 5.3 0.4 1.9 0.8 4.9 0.4 258 17 262 255 21.1 0 21.4 21.1 07/14/2005 19:00:00 2.2 0.8 4.2 0.4 2.2 0.9 4.2 0.4 1.5 0.7 3.4 0.4 250 15 239 255 21 0 21.1 20.8 07/14/2005 19:10:00 2.5 1.9 6.1 0.4 2.4 2 6.1 0.4 1.8 1.5 5.3 0.4 326 51 337 255 20.9 0.1 21.1 20.5 07/14/2005 19:20:00 5 0.9 7.2 2.6 4.9 1 7.2 2.6 3.4 1.2 6.5 0.7 15 15 20 255 20.6 0.1 21.1 20.3 07/14/2005 19:30:00 2.9 0.8 5.3 1.1 2.9 0.8 5.3 1.5 1.8 0.7 3.8 0.4 16 24 349 255 20.3 0.1 20.8 20 07/14/2005 19:40:00 3.8 1.1 6.8 1.1 3.9 1.1 6.5 1.5 3.1 1.2 6.5 0.4 65 17 70 255 20.3 0 20.8 20 07/14/2005 19:50:00 1.2 1.3 4.6 0.4 1.2 1.3 4.6 0.4 1 1.1 4.2 0.4 289 107 42 255 20 0.1 20.5 19.4 07/14/2005 20:00:00 2.4 1.2 4.6 0.4 2.3 1.3 4.9 0.4 1.8 1 4.2 0.4 46 27 52 255 18.7 0.4 20 18 07/14/2005 20:10:00 1.3 1.1 4.2 0.4 1.2 1.1 4.2 0.4 1.1 0.8 3 0.4 46 56 127 255 17.3 0.4 18.5 16.8 07/14/2005 20:20:00 3.5 0.6 4.9 1.5 3.5 0.6 4.9 1.9 2.7 0.6 4.2 1.1 137 9 157 255 16.6 0 16.8 16.6 07/14/2005 20:30:00 3.1 0.9 5.3 1.5 3 1 5.3 1.1 2.4 0.8 4.2 0.4 150 8 154 255 16.5 0 16.8 16.3 07/14/2005 20:40:00 0.8 0.5 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 147 2 156 255 16.1 0 16.6 15.7 07/14/2005 20:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.4 1.5 0.4 117 36 139 255 15.7 0 16 15.7 07/14/2005 21:00:00 1.4 0.7 2.6 0.4 1.3 0.8 2.6 0.4 0.8 0.6 2.3 0.4 3 15 353 255 15.6 0 15.7 15.5 07/14/2005 21:10:00 2.1 1.1 4.2 0.4 2 1.2 4.6 0.4 1.8 1.1 4.2 0.4 133 22 144 255 15.7 0 16.3 15.5 07/14/2005 21:20:00 1.8 0.8 4.2 0.4 1.7 0.9 4.2 0.4 1.5 0.8 3.8 0.4 136 9 139 255 15.8 0 16.3 15.7 07/14/2005 21:30:00 3.4 1.1 5.3 1.5 3.4 1.1 5.3 1.1 2.4 1.1 4.9 0.7 126 13 138 255 16 0.2 16.8 15.7 07/14/2005 21:40:00 1.4 0.5 2.3 0.4 1.3 0.5 2.6 0.4 0.5 0.2 1.1 0.4 108 17 112 255 16 0 16.8 15.7 07/14/2005 21:50:00 1.4 0.8 3 0.4 1.3 0.8 3 0.4 0.6 0.4 1.5 0.4 30 41 1 255 15.6 0 16 15.5 07/14/2005 22:00:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 0.7 0.4 1.9 0.4 35 24 10 255 15.4 0 15.7 15.2 07/14/2005 22:10:00 2.5 1.1 4.2 0.4 2.4 1.1 4.2 0.4 2.1 0.9 3.8 0.4 138 23 159 255 15 0 15.5 15.2 07/14/2005 22:20:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 1.5 1.9 0.6 3.4 0.4 165 7 150 255 15.1 0 15.7 15.2 07/14/2005 22:30:00 1.8 0.5 2.3 0.7 1.6 0.6 2.3 0.4 1 0.5 1.9 0.4 149 5 155 255 14.8 0.1 15.7 14.6 07/14/2005 22:40:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 133 12 119 255 14.7 0.1 15.2 14.6 07/14/2005 22:50:00 2 0.5 3 1.1 2 0.6 3.4 0.7 1.7 0.7 3 0.4 142 6 151 255 14.6 0 15.2 14.6 07/14/2005 23:00:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 2.9 0.3 3.4 1.9 148 2 150 255 14.7 0.1 15.2 14.6 07/14/2005 23:10:00 3.5 0.3 4.2 3 3.6 0.3 4.2 3 2.9 0.4 3.8 1.9 140 4 137 255 14.9 0.1 15.5 14.6 07/14/2005 23:20:00 2.6 0.7 3.4 0.4 2.7 0.8 3.8 0.4 1.8 0.8 3 0.4 136 6 139 255 15 0.1 15.7 14.9 07/14/2005 23:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 84 64 121 255 14.7 0.1 15.2 14.6 07/14/2005 23:40:00 0.9 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.8 0.5 2.3 0.4 36 49 32 255 14.6 0.1 15.2 14.4 07/14/2005 23:50:00 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 4 13 21 255 14.4 0 14.9 14.4 07/15/2005 00:00:00 1.7 1.4 4.6 0.4 1.7 1.5 4.6 0.4 1.3 1.2 4.2 0.4 51 15 64 255 14.4 0 14.9 14.4 07/15/2005 00:10:00 2 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.2 0.7 3 0.4 49 16 71 255 14.4 0 14.9 14.4 07/15/2005 00:20:00 1.3 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.4 1.9 0.4 61 22 71 255 14.2 0.1 14.6 14.1 07/15/2005 00:30:00 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 51 5 63 255 13.8 0.1 14.6 13.3 07/15/2005 00:40:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 106 16 113 255 13.3 0 13.8 13 07/15/2005 00:50:00 1.9 0.3 2.6 0.7 1.9 0.4 2.6 0.7 1.4 0.5 2.6 0.4 105 17 114 255 12.9 0 13.5 12.7 07/15/2005 01:00:00 2.8 0.5 5.3 1.5 2.7 0.6 5.3 1.5 1.8 0.6 3.8 0.4 84 15 72 255 12.7 0 13.3 12.5 07/15/2005 01:10:00 3 0.6 4.9 1.5 3 0.7 4.9 1.5 2.2 0.6 3.8 0.4 61 13 58 255 12.7 0 13.3 12.5 07/15/2005 01:20:00 2.8 0.8 5.3 0.7 2.8 0.7 4.6 0.7 1.9 0.8 3.8 0.4 57 17 57 255 13.1 0 13.3 12.7 07/15/2005 01:30:00 3.2 0.5 4.6 1.5 3.3 0.6 4.9 1.5 2.2 0.7 3.8 0.4 75 13 63 255 12.9 0.1 13.3 12.7 07/15/2005 01:40:00 2.9 0.6 4.2 1.9 2.8 0.7 4.2 1.9 1.7 0.7 3.4 0.4 89 8 92 255 12.7 0 12.7 12.5 07/15/2005 01:50:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.9 2.3 0.6 3.8 0.7 100 8 97 255 12.1 0.2 12.5 11.9 07/15/2005 02:00:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.5 2.4 0.6 3.8 1.1 101 8 94 255 12.1 0.1 12.7 11.9 07/15/2005 02:10:00 2 0.5 3 0.4 1.9 0.5 3 0.4 1.1 0.5 2.3 0.4 120 16 98 255 11.9 0.1 12.5 11.7 07/15/2005 02:20:00 2.2 0.5 3.4 1.1 2.1 0.5 3 1.1 1.6 0.4 2.6 0.4 125 11 129 255 11.6 0 11.9 11.4 07/15/2005 02:30:00 2.5 0.5 3.8 1.5 2.6 0.6 3.8 1.1 2 0.4 3.4 0.7 128 12 112 255 11.5 0.2 12.2 11.4 07/15/2005 02:40:00 1.8 0.7 4.2 0.4 1.6 0.8 3.4 0.4 1 0.6 2.3 0.4 125 10 94 255 11.7 0 12.2 11.7 07/15/2005 02:50:00 3.2 0.8 5.3 1.5 3.2 0.9 4.9 1.5 2.4 0.8 3.8 0.4 129 10 116 255 11.7 0.1 12.5 11.7 07/15/2005 03:00:00 4 0.6 5.7 2.6 4 0.6 5.3 2.3 3.1 0.5 4.6 1.9 126 10 131 255 12.5 0.2 13.3 12.2 07/15/2005 03:10:00 3 0.8 4.6 1.1 2.9 0.8 4.6 0.7 1.9 0.7 3.8 0.4 112 17 136 255 12.9 0 13.3 12.7 07/15/2005 03:20:00 2 1.2 4.2 0.4 1.8 1.2 4.6 0.4 1.5 1 3.8 0.4 273 102 294 255 12.4 0.1 13 12.2 07/15/2005 03:30:00 0.9 0.6 2.3 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 321 53 86 255 11.9 0.1 12.5 11.7 07/15/2005 03:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 295 255 11.5 0 11.9 11.4 07/15/2005 03:50:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 21 13 18 255 11.1 0 11.7 10.9 07/15/2005 04:00:00 1.7 0.6 3 0.4 1.6 0.6 2.6 0.4 1.1 0.5 1.9 0.4 86 27 113 255 10.7 0.1 11.4 10.6 07/15/2005 04:10:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 0.7 1.6 0.5 3 0.4 117 12 102 255 10.5 0 11.1 10.6 07/15/2005 04:20:00 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.4 1.2 0.6 2.6 0.4 111 17 101 255 10.9 0 11.4 10.9 07/15/2005 04:30:00 2.5 0.3 3.4 1.9 2.4 0.3 3.4 1.5 1.5 0.3 2.3 0.4 90 7 83 255 10.8 0.1 11.1 10.6 07/15/2005 04:40:00 2.1 0.4 3 1.1 2 0.5 3 0.7 1.3 0.4 2.3 0.4 114 11 116 255 10.7 0 10.9 10.6 07/15/2005 04:50:00 2.3 0.6 3.4 0.7 2.2 0.5 3.4 0.7 1.6 0.5 3 0.4 124 13 108 255 10.9 0.1 11.7 10.9 07/15/2005 05:00:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 0.8 0.6 2.6 0.4 118 13 109 255 11.7 0.2 12.5 11.4 07/15/2005 05:10:00 2 0.5 3 0.4 1.9 0.5 3 0.4 1.7 0.5 3 0.4 131 12 137 255 12.5 0.2 13.3 11.9 07/15/2005 05:20:00 1.6 0.6 3 0.4 1.5 0.7 3 0.4 1 0.7 3 0.4 118 15 140 255 12.7 0 13 12.5 07/15/2005 05:30:00 1.7 0.5 2.6 0.4 1.5 0.6 2.6 0.4 0.9 0.5 2.3 0.4 110 13 97 255 12.7 0 12.7 12.7 07/15/2005 05:40:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 135 10 126 255 13 0.1 13.3 12.7 07/15/2005 05:50:00 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 121 15 111 255 13.5 0.1 13.8 13 07/15/2005 06:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 122 26 140 255 14.2 0.3 15.2 13.8 07/15/2005 06:10:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 110 17 105 255 15.3 0.3 16.3 14.9 07/15/2005 06:20:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 94 15 83 255 16.5 0.1 17.1 16 07/15/2005 06:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 123 17 102 255 16.8 0 17.1 16.8 07/15/2005 06:40:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 92 26 92 255 17.3 0.2 17.7 16.8 07/15/2005 06:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 67 5 79 255 17.8 0.1 18 17.4 07/15/2005 07:00:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 113 35 120 255 17.8 0.2 18.2 17.4 07/15/2005 07:10:00 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 122 23 102 255 17.8 0 18 17.4 07/15/2005 07:20:00 1.6 0.7 3.4 0.4 1.5 0.7 3 0.4 1.4 0.6 2.6 0.4 109 22 96 255 17.8 0.1 18.5 17.7 07/15/2005 07:30:00 1.9 0.5 3 0.4 1.9 0.5 3 0.4 1.5 0.6 3 0.4 92 20 88 255 18.2 0 18.5 18.2 07/15/2005 07:40:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 94 17 93 255 18.5 0.1 19.1 18.2 07/15/2005 07:50:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 54 22 36 255 19 0.1 19.7 18.5 07/15/2005 08:00:00 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 33 26 19 255 19.2 0 19.7 19.1 07/15/2005 08:10:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 9 23 18 255 19.5 0.1 20 19.1 07/15/2005 08:20:00 1.3 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.4 2.3 0.4 29 15 39 255 19.5 0 20 19.1 07/15/2005 08:30:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.5 0.6 2.6 0.4 16 23 331 255 19.6 0.1 20 19.4 07/15/2005 08:40:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 1.3 0.6 3.4 0.4 359 12 6 255 20.3 0.1 20.5 20 07/15/2005 08:50:00 1.1 0.5 2.6 0.4 1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 351 19 15 255 20.3 0.2 20.5 19.7 07/15/2005 09:00:00 1.8 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.3 0.5 2.3 0.4 33 29 41 255 20.1 0.2 20.8 19.7 07/15/2005 09:10:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 53 35 42 255 20.1 0 20.8 20 07/15/2005 09:20:00 2.2 0.7 4.2 0.4 2.2 0.6 3.8 0.4 2 0.7 3.8 0.4 32 21 44 255 20.3 0.1 20.8 20 07/15/2005 09:30:00 2.1 0.4 3.4 0.7 2.1 0.5 3.4 0.7 2 0.5 3 0.7 37 18 9 255 20 0 20.3 19.7 07/15/2005 09:40:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 41 27 30 255 20.3 0 20.5 20 07/15/2005 09:50:00 1.8 0.7 3 0.4 1.7 0.7 3.4 0.4 1.5 0.6 2.6 0.4 20 22 34 255 21.1 0.3 21.7 20.5 07/15/2005 10:00:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.5 0.7 3 0.4 19 20 358 255 21.6 0 22 21.7 07/15/2005 10:10:00 1.5 0.6 3.4 0.4 1.4 0.6 3.8 0.4 1.3 0.6 3 0.4 19 26 11 255 21.8 0 22 21.7 07/15/2005 10:20:00 2.2 0.6 4.2 0.4 2.1 0.6 4.2 0.4 1.7 0.7 3.4 0.4 357 23 353 255 22.2 0 22.6 22 07/15/2005 10:30:00 2.2 0.8 3.8 0.4 2.1 0.9 4.2 0.4 1.7 0.8 4.2 0.4 6 28 20 255 22.7 0.1 23.5 22.6 07/15/2005 10:40:00 2.2 0.5 3.4 1.1 2.2 0.5 3.8 0.7 2 0.6 3.4 0.4 24 19 30 255 22.8 0.1 23.5 22.6 07/15/2005 10:50:00 2.3 0.6 3.8 0.4 2.2 0.6 3.8 0.4 2.1 0.6 3.4 0.4 26 19 12 255 22.5 0.2 23.2 22.3 07/15/2005 11:00:00 1.3 0.8 3 0.4 1.2 0.8 3 0.4 1.1 0.7 2.6 0.4 317 27 324 255 22.8 0.1 23.5 22.6 07/15/2005 11:10:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.7 3.4 0.4 351 26 351 255 23.3 0 23.5 22.9 07/15/2005 11:20:00 2.1 0.7 3.8 0.4 2 0.7 3.8 0.4 1.8 0.7 3.8 0.4 296 39 323 255 23.5 0 23.8 23.5 07/15/2005 11:30:00 1.9 0.7 4.2 0.4 1.8 0.8 4.6 0.4 1.6 0.8 3.4 0.4 287 22 311 255 23.3 0 23.5 23.2 07/15/2005 11:40:00 1.2 0.7 3.4 0.4 1.1 0.7 3 0.4 1 0.6 2.6 0.4 230 98 342 255 23.2 0 23.5 22.9 07/15/2005 11:50:00 2.3 0.9 4.2 0.4 2.1 0.9 4.6 0.4 1.9 0.9 3.8 0.4 305 41 322 255 23.6 0.2 24.1 23.2 07/15/2005 12:00:00 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 1.2 0.7 2.6 0.4 294 79 323 255 23.8 0 24.4 23.5 07/15/2005 12:10:00 1.7 1 3.4 0.4 1.6 1 3.4 0.4 1.3 1 4.2 0.4 284 39 301 255 24.1 0.2 24.4 23.5 07/15/2005 12:20:00 1.8 1 4.2 0.4 1.8 1 4.2 0.4 1.4 0.8 3.4 0.4 327 41 312 255 24.4 0 24.7 24.4 07/15/2005 12:30:00 2.7 0.8 4.2 0.7 2.6 0.8 4.2 0.7 2 0.8 4.2 0.4 347 24 336 255 24.7 0.1 25 24.4 07/15/2005 12:40:00 2.1 0.7 4.2 0.7 2 0.8 4.2 0.4 1.7 0.8 3.8 0.4 25 29 4 255 24.6 0.1 25 24.4 07/15/2005 12:50:00 2.3 0.8 4.6 0.4 2.2 0.8 4.6 0.4 1.8 0.7 3.8 0.4 359 32 25 255 25 0 25.3 25 07/15/2005 13:00:00 2.6 1.1 5.7 0.4 2.3 1 5.3 0.4 2 1.2 5.7 0.4 312 29 335 255 25.1 0.1 25.3 25 07/15/2005 13:10:00 2.3 0.8 4.6 0.4 2.1 0.9 4.2 0.4 1.8 1 4.2 0.4 305 47 328 255 25.1 0 25.3 25 07/15/2005 13:20:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 281 41 263 255 25.2 0 25.6 25.3 07/15/2005 13:30:00 1.3 0.8 3.4 0.4 1.1 0.7 3 0.4 0.9 0.7 3 0.4 341 51 338 255 25.4 0 25.9 25.3 07/15/2005 13:40:00 1 0.7 3.4 0.4 1 0.6 3.4 0.4 0.9 0.5 2.3 0.4 300 61 352 255 25 0.1 25.6 24.7 07/15/2005 13:50:00 2.5 0.6 3.8 0.7 2.4 0.6 3.8 0.7 2.1 0.7 3.8 0.4 321 32 20 255 25.4 0 25.6 25 07/15/2005 14:00:00 1.2 1 4.2 0.4 1.2 0.9 3.8 0.4 1 0.8 3 0.4 13 69 32 255 25.5 0 25.6 25.3 07/15/2005 14:10:00 2.4 0.9 4.6 0.7 2.2 1 4.6 0.4 1.9 0.9 3.4 0.4 342 33 26 255 25.9 0 26.2 25.6 07/15/2005 14:20:00 1.3 0.7 3 0.4 1.1 0.7 2.6 0.4 1.1 0.7 3.4 0.4 286 51 349 255 26.3 0 26.5 25.9 07/15/2005 14:30:00 1.9 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.5 0.6 3.4 0.4 260 36 244 255 26.5 0.2 26.8 26.2 07/15/2005 14:40:00 1.2 0.7 3 0.4 1.2 0.8 3 0.4 1.1 0.6 2.6 0.4 214 64 317 255 26.3 0 26.5 26.2 07/15/2005 14:50:00 1.7 0.8 4.2 0.4 1.7 0.9 3.8 0.4 1.5 1 3.8 0.4 281 41 253 255 26.7 0 27.1 26.5 07/15/2005 15:00:00 1.8 0.7 3.4 0.4 1.7 0.7 3 0.4 1.5 0.7 3.4 0.4 297 36 334 255 26.1 0 26.5 25.9 07/15/2005 15:10:00 2.2 0.6 4.2 0.4 2 0.6 3.4 0.4 1.8 0.8 3.8 0.4 331 23 336 255 25.7 0 25.9 25.6 07/15/2005 15:20:00 2.1 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.7 1 3.8 0.4 315 28 307 255 25.7 0 25.9 25.6 07/15/2005 15:30:00 2.5 0.6 3.8 0.7 2.4 0.6 3.8 1.1 2 0.7 3.4 0.4 305 18 291 255 25.7 0 26.2 25.3 07/15/2005 15:40:00 2.3 0.7 4.2 0.7 2.1 0.8 3.8 0.4 1.8 0.9 4.2 0.4 293 26 275 255 25.5 0 25.6 25.3 07/15/2005 15:50:00 1.9 1 4.2 0.4 1.8 1 4.2 0.4 1.3 1 3.8 0.4 290 41 255 255 25.5 0.1 25.9 25.3 07/15/2005 16:00:00 2.7 1.2 4.9 0.4 2.7 1.2 4.9 0.4 2.2 1.2 4.6 0.4 267 30 277 255 25 0.3 25.6 24.4 07/15/2005 16:10:00 2.8 1 4.9 0.7 2.8 0.9 4.9 0.7 2.1 1 4.6 0.4 277 23 227 255 24.3 0 24.4 24.1 07/15/2005 16:20:00 2.9 1 4.6 0.4 2.8 1.1 4.9 0.4 2 0.9 4.6 0.4 279 20 280 255 24.4 0 24.7 24.4 07/15/2005 16:30:00 2.9 0.8 4.6 0.4 2.9 1 4.6 0.4 2.2 0.8 4.2 0.4 278 18 264 255 24.1 0 24.4 24.1 07/15/2005 16:40:00 2.1 0.8 3.8 0.4 2 0.9 4.2 0.4 1.6 0.8 4.2 0.4 259 30 271 255 24 0.1 24.4 23.8 07/15/2005 16:50:00 2.3 0.8 4.6 0.4 2.2 0.9 4.6 0.4 1.6 0.7 3.8 0.4 243 18 262 255 23.6 0 23.8 23.5 07/15/2005 17:00:00 2.1 0.7 3.8 0.4 2.1 0.7 4.2 0.4 1.6 0.9 3.8 0.4 252 17 241 255 23.4 0 23.5 23.5 07/15/2005 17:10:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.7 0.4 2.3 0.4 229 15 216 255 23.1 0 23.5 23.2 07/15/2005 17:20:00 0.8 0.5 1.9 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 279 13 271 255 23 0 23.2 22.9 07/15/2005 17:30:00 1 0.8 3.4 0.4 0.9 0.8 3 0.4 0.8 0.6 3 0.4 291 23 284 255 22.7 0 23.2 22.6 07/15/2005 17:40:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 299 13 299 255 22.5 0.1 23.2 22.3 07/15/2005 17:50:00 1.7 0.5 3 0.7 1.6 0.6 3 0.4 1.1 0.7 2.6 0.4 286 15 283 255 22.2 0 22.9 22.3 07/15/2005 18:00:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.1 0.6 3 0.4 293 15 300 255 22.2 0 22.3 22.3 07/15/2005 18:10:00 1.8 0.4 3 0.7 1.6 0.5 2.6 0.4 1.1 0.7 2.6 0.4 309 15 329 255 22.6 0 22.9 22.3 07/15/2005 18:20:00 2.4 0.6 3.8 0.7 2.3 0.6 3.4 0.7 1.8 0.7 4.2 0.4 306 15 308 255 23 0 23.5 22.9 07/15/2005 18:30:00 2 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.4 0.9 3.8 0.4 326 19 310 255 23.2 0 23.5 23.2 07/15/2005 18:40:00 2.2 0.7 4.2 0.7 1.9 0.7 4.2 0.4 1.6 0.9 3.8 0.4 333 15 329 255 23.3 0 23.8 23.2 07/15/2005 18:50:00 2.1 0.4 3 1.1 1.8 0.4 3 0.7 1.5 0.6 3 0.4 335 13 342 255 22.8 0.1 23.5 22.6 07/15/2005 19:00:00 2 0.6 3 0.4 1.8 0.7 3 0.4 1.2 0.7 3 0.4 324 9 323 255 22 0.2 23.2 21.7 07/15/2005 19:10:00 1.9 0.4 2.6 0.7 1.5 0.4 2.3 0.7 1.3 0.5 2.3 0.4 334 8 334 255 21.4 0 21.7 21.1 07/15/2005 19:20:00 2.4 0.4 3.4 1.1 1.9 0.4 2.6 1.1 1.3 0.5 2.3 0.4 336 9 343 255 20.7 0.2 21.1 20.3 07/15/2005 19:30:00 2.6 0.4 3.4 1.5 2.3 0.4 3.4 1.1 1.4 0.5 3 0.4 323 13 322 255 19.9 0.3 20.8 19.4 07/15/2005 19:40:00 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 0.8 0.4 1.9 0.4 346 12 321 255 19.2 0.2 20 18.8 07/15/2005 19:50:00 1.9 0.7 3.8 0.7 1.8 0.7 3.8 0.4 1.1 0.6 3 0.4 15 13 42 255 18.7 0 19.1 18.5 07/15/2005 20:00:00 2.3 0.6 3.8 0.7 2.2 0.6 3.4 0.4 1.2 0.7 2.6 0.4 13 13 350 255 18.6 0 19.1 18.5 07/15/2005 20:10:00 2.1 0.5 3.4 0.4 2 0.6 3.4 0.4 1 0.6 2.6 0.4 13 17 6 255 18.8 0 19.1 18.5 07/15/2005 20:20:00 2 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.1 0.6 2.6 0.4 14 11 13 255 18.9 0 19.1 18.8 07/15/2005 20:30:00 1.6 0.6 2.6 0.4 1.4 0.7 2.6 0.4 0.9 0.6 2.6 0.4 26 13 18 255 18.8 0 18.8 18.5 07/15/2005 20:40:00 1.6 0.6 2.6 0.4 1.5 0.7 2.6 0.4 0.8 0.6 2.6 0.4 25 11 21 255 18.5 0.1 18.8 18.2 07/15/2005 20:50:00 1.2 0.4 2.6 0.4 1 0.5 2.6 0.4 0.4 0.2 1.5 0.4 17 9 31 255 18 0 18.2 17.7 07/15/2005 21:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 11 17 16 255 17.5 0.1 17.7 17.1 07/15/2005 21:10:00 1.1 0.3 2.3 0.4 0.7 0.3 1.9 0.4 0.5 0.2 1.1 0.4 356 3 345 255 17.3 0 17.4 17.1 07/15/2005 21:20:00 1.4 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 340 4 345 255 17.2 0 17.1 16.8 07/15/2005 21:30:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 341 17 337 255 17.1 0 17.1 16.8 07/15/2005 21:40:00 1.4 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.5 0.3 1.5 0.4 273 5 265 255 16.8 0 17.1 16.6 07/15/2005 21:50:00 1.5 0.4 2.3 0.4 1.4 0.5 2.3 0.4 0.7 0.4 1.9 0.4 255 9 248 255 16.4 0.1 16.8 16.3 07/15/2005 22:00:00 1.4 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 255 3 253 255 16.1 0 16.6 16 07/15/2005 22:10:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 346 72 49 255 15.7 0 16.3 15.5 07/15/2005 22:20:00 1.1 0.3 1.5 0.4 1 0.4 1.5 0.4 0.5 0.2 1.1 0.4 19 11 24 255 15.3 0.1 15.7 15.2 07/15/2005 22:30:00 1.6 0.4 2.3 0.7 1.3 0.3 2.3 0.4 0.6 0.3 1.5 0.4 354 9 347 255 15 0 15.5 14.9 07/15/2005 22:40:00 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 353 11 349 255 14.7 0.1 15.2 14.6 07/15/2005 22:50:00 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.8 0.4 1.5 0.4 32 9 21 255 14.5 0.1 14.9 14.4 07/15/2005 23:00:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.3 1.9 0.4 21 0 21 255 14.3 0 14.6 14.4 07/15/2005 23:10:00 1.2 0.4 1.9 0.4 1 0.4 2.3 0.4 0.6 0.3 1.5 0.4 66 19 69 255 14.4 0 15.2 14.4 07/15/2005 23:20:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 0.5 0.3 1.5 0.4 90 11 94 255 14.6 0 15.2 14.6 07/15/2005 23:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 121 15 105 255 14.6 0.1 15.2 14.6 07/15/2005 23:40:00 1.3 0.3 2.3 0.4 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 146 5 151 255 14.8 0 15.2 14.6 07/15/2005 23:50:00 1.7 0.6 3.4 0.4 1.5 0.7 3 0.4 1 0.5 1.9 0.4 114 23 90 255 14.8 0.1 15.2 14.6 07/16/2005 00:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 126 16 113 255 14.6 0.1 15.2 14.6 07/16/2005 00:10:00 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1.5 0.3 2.3 0.7 148 15 155 255 14.6 0.1 15.2 14.6 07/16/2005 00:20:00 1.8 0.4 2.6 0.7 1.7 0.5 3 0.4 1.3 0.7 2.6 0.4 138 12 129 255 14.6 0 15.2 14.6 07/16/2005 00:30:00 2.7 0.7 3.8 0.7 2.6 0.8 3.8 0.4 2 0.7 3.4 0.4 98 14 93 255 14.6 0 15.2 14.6 07/16/2005 00:40:00 1.7 0.8 3.8 0.4 1.6 0.9 3.8 0.4 1.2 0.7 3.4 0.4 115 13 108 255 14.7 0 15.2 14.4 07/16/2005 00:50:00 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.3 0.4 102 12 93 255 14.1 0.2 14.9 13.8 07/16/2005 01:00:00 1.7 0.6 3 0.4 1.5 0.7 3 0.4 1.1 0.6 2.6 0.4 62 24 97 255 13.8 0 14.1 13.5 07/16/2005 01:10:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 9 45 275 255 13.4 0.1 13.8 13 07/16/2005 01:20:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.6 2.3 0.4 23 72 73 255 13.2 0 13.8 13 07/16/2005 01:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 69 0 69 255 13.2 0.2 13.8 13 07/16/2005 01:40:00 1.6 0.5 2.6 0.4 1.5 0.6 2.6 0.4 0.7 0.4 1.9 0.4 49 15 46 255 12.8 0 13.5 12.7 07/16/2005 01:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 79 47 66 255 12.9 0 13.3 12.7 07/16/2005 02:00:00 1.9 0.8 3.8 0.4 1.8 0.9 3.8 0.4 1.2 0.6 3.4 0.4 224 15 215 255 13.1 0 13.5 13 07/16/2005 02:10:00 1.5 0.7 3 0.4 1.4 0.7 2.6 0.4 1 0.5 2.3 0.4 158 39 202 255 13.4 0 13.8 13 07/16/2005 02:20:00 1.1 0.8 3 0.4 1 0.7 2.6 0.4 0.6 0.4 2.3 0.4 98 38 64 255 13.5 0 13.8 13.3 07/16/2005 02:30:00 0.6 0.4 1.5 0.4 0.5 0.4 1.5 0.4 0.4 0.2 1.1 0.4 32 3 31 255 13.1 0.2 13.8 12.7 07/16/2005 02:40:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 59 23 113 255 12.7 0 13.3 12.5 07/16/2005 02:50:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 123 24 131 255 12.3 0 12.7 12.2 07/16/2005 03:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 104 3 105 255 12.1 0 12.5 11.9 07/16/2005 03:10:00 0.9 0.7 2.6 0.4 0.8 0.7 2.3 0.4 0.8 0.6 2.3 0.4 78 26 90 255 12 0 12.2 11.9 07/16/2005 03:20:00 1.9 0.5 3 0.4 1.8 0.5 3.4 0.4 1.1 0.5 2.3 0.4 77 26 94 255 11.9 0.1 12.2 11.7 07/16/2005 03:30:00 1.3 0.6 2.3 0.4 1.2 0.6 2.3 0.4 0.7 0.4 1.9 0.4 57 13 43 255 11.7 0 12.2 11.7 07/16/2005 03:40:00 2 0.5 3.8 1.1 1.9 0.6 3.4 0.7 1.2 0.5 2.6 0.4 78 9 92 255 11.7 0 12.2 11.7 07/16/2005 03:50:00 1.9 0.8 3.4 0.7 1.8 0.8 3.4 0.4 1.1 0.6 2.6 0.4 67 12 84 255 11.8 0.1 12.5 11.7 07/16/2005 04:00:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 67 13 52 255 12.1 0 12.7 11.9 07/16/2005 04:10:00 1.8 0.6 3 0.4 1.7 0.7 3 0.4 0.8 0.5 2.3 0.4 84 12 79 255 12.4 0 12.7 12.2 07/16/2005 04:20:00 1.6 0.6 2.6 0.4 1.5 0.7 2.6 0.4 0.7 0.4 1.9 0.4 72 16 94 255 12.5 0 12.7 12.5 07/16/2005 04:30:00 1.7 0.5 3 0.7 1.6 0.5 3.4 0.7 1 0.5 2.3 0.4 34 19 62 255 12.7 0 13 12.5 07/16/2005 04:40:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 40 18 30 255 12.8 0 13.3 12.7 07/16/2005 04:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 46 27 74 255 12.8 0 13 12.7 07/16/2005 05:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 285 32 310 255 12.8 0 13.3 12.7 07/16/2005 05:10:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 226 8 220 255 12.9 0.1 13.3 12.7 07/16/2005 05:20:00 1.8 0.8 3 0.4 1.7 0.8 3 0.4 1.7 0.6 3 0.7 159 21 163 255 13 0.1 13 12.7 07/16/2005 05:30:00 2.4 0.3 3 1.9 2.3 0.3 3 1.5 1.8 0.5 2.6 0.4 146 10 150 255 13.1 0 13.3 13 07/16/2005 05:40:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 2 0.3 2.6 1.1 134 7 131 255 13.4 0 13.5 13.3 07/16/2005 05:50:00 2.8 0.5 4.2 1.1 2.7 0.5 3.8 1.1 1.9 0.6 3 0.4 100 17 91 255 13.5 0 13.8 13.5 07/16/2005 06:00:00 2.9 0.5 4.2 1.9 2.8 0.5 3.8 1.5 1.9 0.5 3.4 0.4 82 9 76 255 13.9 0 14.1 13.8 07/16/2005 06:10:00 2.6 0.5 4.2 1.1 2.5 0.5 3.8 0.7 1.7 0.5 3 0.4 101 11 100 255 14.2 0.2 14.6 13.8 07/16/2005 06:20:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 2.2 0.6 3.4 0.4 99 11 88 255 15 0.1 15.7 14.6 07/16/2005 06:30:00 2.7 0.5 3.8 1.5 2.6 0.6 3.8 1.1 1.9 0.6 3.4 0.4 86 10 91 255 15.2 0.1 16 15.2 07/16/2005 06:40:00 2.7 0.6 4.2 1.5 2.7 0.6 4.2 0.7 1.9 0.7 3.4 0.4 87 12 91 255 15.5 0 16 15.5 07/16/2005 06:50:00 2.8 0.6 4.6 1.5 2.8 0.6 4.2 1.5 1.9 0.7 3.4 0.4 93 12 92 255 15.6 0 16 15.5 07/16/2005 07:00:00 2.5 0.6 3.8 0.7 2.4 0.6 4.2 0.7 1.9 0.6 3.8 0.4 78 15 97 255 15.7 0 16.3 15.5 07/16/2005 07:10:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 0.7 2.1 0.7 3.8 0.4 67 16 65 255 15.9 0 16.6 15.7 07/16/2005 07:20:00 2.8 0.8 4.9 1.1 2.8 0.9 5.3 0.7 2.1 0.8 4.6 0.4 40 14 44 255 16.1 0.1 16.8 16 07/16/2005 07:30:00 3.8 1 6.1 1.5 3.7 1 6.1 1.5 2.9 1 5.7 0.4 44 15 40 255 16.7 0.1 17.1 16.3 07/16/2005 07:40:00 5.6 1.1 9.1 3.4 5.6 1.1 9.1 3.4 4.8 1.2 8 1.9 28 12 13 255 17.2 0.1 17.7 16.8 07/16/2005 07:50:00 6.1 1 8.4 3.4 6 1 8.8 3.4 5 1.1 7.6 1.9 29 13 23 255 17.5 0 17.7 17.1 07/16/2005 08:00:00 6.1 1 8.8 3.4 6.1 1 8.8 3.4 5 1.2 8.4 2.3 42 13 51 255 17.6 0 17.7 17.4 07/16/2005 08:10:00 4.9 1.1 8 2.3 4.8 1.1 8 2.3 4 1.3 7.2 1.1 55 15 39 255 17.5 0 18 17.4 07/16/2005 08:20:00 3.2 0.8 5.3 1.1 3.2 0.8 5.3 1.1 2.6 0.9 4.9 0.4 69 14 49 255 17.5 0.1 18 17.1 07/16/2005 08:30:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 1.9 2.7 0.8 4.6 0.7 74 12 84 255 17.5 0.1 18 17.1 07/16/2005 08:40:00 2.8 0.8 4.6 0.4 2.7 0.8 4.6 0.4 2.1 0.9 4.6 0.4 86 17 67 255 17.4 0.1 18 17.1 07/16/2005 08:50:00 3.3 1 5.7 1.5 3.4 1 6.1 1.1 2.9 1 5.3 0.4 66 22 66 255 17.3 0.1 17.7 17.1 07/16/2005 09:00:00 3.9 0.8 5.3 1.5 3.9 0.8 5.7 1.1 3.2 0.8 6.1 1.1 47 16 27 255 17.5 0.1 18 17.1 07/16/2005 09:10:00 3.1 0.9 5.7 1.1 3 0.9 5.7 0.4 2.4 0.8 4.9 0.7 59 17 48 255 17.4 0.1 18 17.1 07/16/2005 09:20:00 3.6 1 5.7 1.9 3.6 1 6.1 1.1 2.9 1.1 5.7 0.4 65 15 46 255 17.3 0.1 17.7 17.1 07/16/2005 09:30:00 3.2 1.1 5.7 0.7 3.1 1.2 5.7 0.4 2.5 1.1 5.3 0.4 67 20 40 255 17.2 0 17.7 17.1 07/16/2005 09:40:00 2.8 0.9 5.7 1.1 2.7 0.9 5.7 0.7 2.2 0.9 4.6 0.4 72 18 47 255 17.1 0 17.4 16.8 07/16/2005 09:50:00 3.9 1.1 7.2 0.7 3.9 1.2 7.2 0.4 3 1 5.7 0.7 56 19 54 255 17.3 0.1 17.7 17.1 07/16/2005 10:00:00 3.6 1.3 6.8 0.4 3.6 1.4 6.8 0.4 2.9 1.4 5.7 0.4 54 17 44 255 17.5 0 18 17.4 07/16/2005 10:10:00 3.4 0.9 5.7 1.9 3.4 0.9 5.7 1.9 2.7 0.9 5.7 0.4 60 17 57 255 17.6 0 18 17.4 07/16/2005 10:20:00 4.1 1 6.1 1.5 4.1 1.1 6.5 1.5 3.5 1 5.7 1.5 56 19 48 255 17.5 0 18 17.4 07/16/2005 10:30:00 4.4 0.9 6.5 1.1 4.4 0.9 6.5 1.5 3.5 1 6.5 1.5 50 19 68 255 17.5 0.1 17.7 17.4 07/16/2005 10:40:00 5.6 1.2 9.1 2.3 5.5 1.2 8.8 2.6 4.6 1.3 8 1.5 45 16 48 255 17.5 0 18 17.4 07/16/2005 10:50:00 4.7 1.1 8.4 1.9 4.7 1.2 8.4 1.9 3.8 1.2 7.2 1.5 47 20 34 255 17.6 0 18 17.4 07/16/2005 11:00:00 5.3 1.3 9.9 2.6 5.3 1.3 9.5 2.3 4.3 1.4 8 1.5 44 17 23 255 17.8 0 18.2 17.4 07/16/2005 11:10:00 5.8 1.3 9.5 2.6 5.7 1.3 9.1 2.6 4.7 1.3 8 1.9 42 19 32 255 18.2 0.1 18.8 17.7 07/16/2005 11:20:00 6.9 1.5 10.7 3.8 6.8 1.5 10.3 3 5.8 1.6 11.1 3 32 16 20 255 18.7 0 19.1 18.2 07/16/2005 11:30:00 5.9 1.3 10.7 3.4 5.9 1.4 11.1 3 4.7 1.4 9.1 1.9 38 17 39 255 18.8 0 19.1 18.5 07/16/2005 11:40:00 5.5 1.3 9.1 3 5.5 1.3 9.1 2.6 4.4 1.2 7.6 2.3 35 15 38 255 18.8 0 18.8 18.5 07/16/2005 11:50:00 6.5 1.2 9.1 3 6.5 1.2 9.5 3 5.2 1.3 8.4 1.9 30 15 20 255 19.1 0.1 19.4 18.8 07/16/2005 12:00:00 8 1.4 11.5 4.6 8 1.4 11.8 4.6 6.6 1.5 10.3 3.4 28 13 29 255 19.5 0 20 19.4 07/16/2005 12:10:00 8.2 1.7 12.2 4.2 8.1 1.7 12.2 4.6 7 2 11.5 2.6 24 13 8 255 19.9 0.1 20.5 19.7 07/16/2005 12:20:00 7.9 1.3 11.5 4.6 7.8 1.3 11.5 4.6 6.4 1.5 11.1 3 29 14 45 255 21.1 0.2 21.7 20.5 07/16/2005 12:30:00 7.5 1.5 11.5 4.2 7.5 1.5 11.8 3.4 6.2 1.5 10.3 1.9 21 13 19 255 21 0.1 21.4 20.8 07/16/2005 12:40:00 7.4 1.7 11.5 4.2 7.4 1.8 11.5 3.8 5.7 2.2 11.5 1.1 17 15 32 255 20.9 0.3 21.7 20.5 07/16/2005 12:50:00 8.4 1.5 12.2 4.2 8.4 1.5 11.8 4.6 6.7 1.7 11.5 2.3 20 15 38 255 21 0.3 21.7 20.3 07/16/2005 13:00:00 8.2 1.5 11.5 4.2 8.2 1.6 11.8 3.8 6.4 1.8 10.7 2.3 18 11 9 255 20.2 0.1 20.8 19.7 07/16/2005 13:10:00 7.1 1.3 10.7 3 7 1.3 9.9 3.8 5.4 1.5 9.5 1.5 19 13 16 255 19.8 0.1 20.3 19.4 07/16/2005 13:20:00 7.5 1.3 10.3 3.8 7.5 1.3 10.7 3.4 6.2 1.4 9.5 2.3 26 14 16 255 19.5 0 20 19.4 07/16/2005 13:30:00 7.1 1.2 10.7 4.2 7 1.2 10.7 4.2 5.7 1.4 9.9 3 25 13 31 255 19.2 0 19.7 19.1 07/16/2005 13:40:00 7.2 1.2 9.9 4.2 7.2 1.2 10.7 3.8 5.8 1.6 9.5 1.5 20 13 8 255 19.2 0.1 19.7 19.1 07/16/2005 13:50:00 8.2 1.3 11.8 5.3 8.2 1.3 11.5 5.3 6.6 1.6 11.1 1.5 20 11 12 255 19 0 19.4 18.8 07/16/2005 14:00:00 7.6 1.3 11.8 3.4 7.6 1.3 11.8 3.8 6.2 1.7 11.1 2.3 16 12 9 255 19 0 19.1 18.8 07/16/2005 14:10:00 8.2 1.7 12.2 4.6 8.1 1.8 12.6 4.2 6.6 2 11.5 1.5 20 13 12 255 18.9 0 19.1 18.5 07/16/2005 14:20:00 7.1 1.2 9.9 4.2 7 1.2 9.9 3.8 5.3 1.4 9.5 1.5 24 17 31 255 19 0 19.4 18.8 07/16/2005 14:30:00 7 1.4 10.3 3.4 6.9 1.5 9.9 3.4 5.5 1.5 9.5 2.3 29 16 66 255 19.2 0 19.4 19.1 07/16/2005 14:40:00 6.9 1.5 11.5 4.2 6.9 1.5 11.8 3.4 5.4 1.7 9.5 1.9 22 15 14 255 19.4 0 19.4 19.1 07/16/2005 14:50:00 6.7 1.5 11.1 3.4 6.6 1.5 10.7 3 5.2 1.7 10.3 1.1 19 15 10 255 19.2 0.1 19.4 18.8 07/16/2005 15:00:00 6.5 1.6 10.3 3 6.5 1.6 10.7 3 5.2 1.8 10.3 1.5 23 15 30 255 18.7 0.1 19.1 18.5 07/16/2005 15:10:00 7.4 1.5 11.5 2.6 7.4 1.5 11.5 2.3 6.1 1.8 10.7 1.9 20 12 30 255 18.5 0 18.5 18.2 07/16/2005 15:20:00 6.9 1.2 9.5 3.4 6.9 1.2 9.5 3.4 5.4 1.5 9.9 1.5 23 14 24 255 18.3 0 18.2 18.2 07/16/2005 15:30:00 7.7 1.3 11.5 4.2 7.7 1.3 11.8 4.2 6.1 1.6 11.5 2.6 22 15 22 255 18.2 0 18.2 18 07/16/2005 15:40:00 7.3 1.2 11.1 4.2 7.3 1.2 11.1 4.6 5.8 1.2 9.5 2.6 24 13 5 255 18.4 0 18.5 18.2 07/16/2005 15:50:00 7.3 1.4 11.5 3 7.2 1.5 11.1 2.6 5.4 1.7 9.9 1.5 17 13 20 255 18.5 0 18.8 18.2 07/16/2005 16:00:00 7.7 1.3 11.1 3.4 7.6 1.3 10.7 3.4 6 1.8 10.7 1.5 15 13 19 255 18.7 0 18.8 18.5 07/16/2005 16:10:00 7.4 1.2 11.1 4.6 7.3 1.2 11.1 4.6 5.7 1.7 9.5 2.3 19 13 27 255 18.5 0 18.8 18.2 07/16/2005 16:20:00 7.2 1.1 10.3 4.2 7.1 1.1 9.9 3.4 5.5 1.5 9.1 2.6 20 14 39 255 18 0 18.2 17.7 07/16/2005 16:30:00 6.6 1.3 10.3 3.8 6.6 1.3 10.3 3.4 5 1.7 9.9 1.9 20 14 23 255 17.7 0 18 17.4 07/16/2005 16:40:00 6.7 1.3 10.7 2.3 6.7 1.3 10.3 2.3 5.1 1.6 8.8 1.1 15 12 19 255 17.3 0 17.7 17.1 07/16/2005 16:50:00 5.5 1.3 8.8 2.3 5.5 1.3 8.8 2.3 4 1.4 7.2 1.1 15 12 19 255 17.1 0 17.1 16.8 07/16/2005 17:00:00 6.1 1.1 8.8 3.4 6 1.1 8.8 3 4.6 1.3 8 1.5 19 14 31 255 17.1 0 17.1 16.8 07/16/2005 17:10:00 6.7 1.2 9.9 3.4 6.7 1.2 9.9 3 5.1 1.5 8.8 1.1 14 11 11 255 17.1 0 17.4 16.8 07/16/2005 17:20:00 6.9 1 9.5 4.2 6.9 1.1 9.5 3.8 5.3 1.3 8.4 1.9 17 12 12 255 17.1 0 17.1 16.8 07/16/2005 17:30:00 6.8 1.5 10.7 3 6.8 1.5 9.9 2.6 5.1 1.7 9.1 1.9 14 15 30 255 16.8 0 17.1 16.8 07/16/2005 17:40:00 6.7 1.2 9.5 1.1 6.7 1.3 9.5 1.1 4.9 1.5 8.8 1.5 12 14 21 255 17 0.1 17.4 16.8 07/16/2005 17:50:00 7 1.3 10.7 3.4 7 1.3 10.7 3.4 5.4 1.7 9.5 1.5 14 12 4 255 17.4 0.1 18 17.1 07/16/2005 18:00:00 7 1.3 9.9 3.8 7 1.3 10.3 3.4 5.3 1.7 9.5 1.5 17 11 358 255 17.7 0 18 17.4 07/16/2005 18:10:00 6.2 1.1 9.1 3.4 6.2 1.1 9.1 3.4 4.8 1.5 8 1.1 16 12 22 255 17.6 0 18 17.4 07/16/2005 18:20:00 5.8 1.3 9.5 2.3 5.8 1.4 9.9 2.6 4 1.7 9.1 0.7 12 13 1 255 17.4 0.1 17.7 17.1 07/16/2005 18:30:00 6.3 1.2 10.3 3 6.3 1.2 9.9 3.4 5 1.5 9.1 1.9 18 12 26 255 17.3 0 17.7 17.1 07/16/2005 18:40:00 5.4 1 8.4 3 5.4 1 8 3 4 1.1 7.6 1.5 17 12 7 255 17.3 0 17.7 17.1 07/16/2005 18:50:00 5.7 1 8.4 3 5.7 1 8.4 3 4.4 1.2 7.6 1.1 25 15 7 255 17.2 0 17.7 16.8 07/16/2005 19:00:00 6.4 1.3 9.5 2.3 6.3 1.3 9.1 1.9 5.3 1.2 8.4 2.3 30 15 28 255 16.9 0.1 17.4 16.8 07/16/2005 19:10:00 6 1.1 9.5 3.4 6 1.1 9.1 3.4 5.1 1.2 7.6 1.5 27 13 19 255 16.7 0 17.1 16.6 07/16/2005 19:20:00 5.4 0.9 7.6 3 5.4 0.9 7.6 2.6 4.5 1 6.8 2.6 27 12 24 255 16.7 0 17.1 16.6 07/16/2005 19:30:00 4.9 1 7.6 2.3 4.9 1 7.6 2.3 3.9 1.2 7.6 1.1 29 15 33 255 16.6 0 16.8 16.6 07/16/2005 19:40:00 4.8 1 8 3 4.9 1 8 3 4 1 6.8 1.9 29 15 10 255 16.7 0 17.1 16.6 07/16/2005 19:50:00 4.9 1 9.1 2.6 4.9 1 9.1 2.3 3.7 1.2 8 0.7 20 15 17 255 16.7 0 17.1 16.6 07/16/2005 20:00:00 5.4 1.1 8.4 2.6 5.4 1.1 8.4 2.6 4.3 1.2 8 1.5 25 14 1 255 16.7 0 17.1 16.6 07/16/2005 20:10:00 5.8 1.1 9.1 3 5.8 1.1 9.1 2.6 4.9 1 7.6 2.3 33 12 32 255 16.6 0 16.8 16.6 07/16/2005 20:20:00 5.1 1 8 3 5.1 1 8 3 3.9 1.2 7.6 1.5 20 13 17 255 16.4 0 16.8 16.3 07/16/2005 20:30:00 4.6 0.9 7.2 2.3 4.5 0.9 7.2 2.3 3.1 1 5.7 0.7 18 17 11 255 16.1 0 16.8 16 07/16/2005 20:40:00 5.9 1.1 9.5 2.6 5.9 1.1 9.1 3 4.7 1.2 7.6 1.9 24 13 20 255 16 0 16.6 16 07/16/2005 20:50:00 6.1 1 8.8 3.8 6 1 8.8 4.2 4.8 1.1 7.6 1.9 25 14 24 255 15.9 0 16.3 15.7 07/16/2005 21:00:00 5.7 1.1 9.1 3 5.7 1.1 9.1 2.6 4.6 1.4 8.8 1.5 18 16 24 255 15.7 0.1 16.3 15.5 07/16/2005 21:10:00 5.8 1.4 9.9 2.3 5.8 1.4 9.9 1.9 4.3 1.6 9.1 0.7 14 13 6 255 15.5 0 16 15.5 07/16/2005 21:20:00 5.1 1.3 8 1.9 5 1.3 8 2.3 3.8 1.3 8 1.1 17 12 28 255 15.3 0 15.7 15.2 07/16/2005 21:30:00 5 0.8 6.8 2.6 5 0.9 7.2 2.3 4.1 1 6.8 1.9 30 16 18 255 15.2 0 15.7 15.2 07/16/2005 21:40:00 4.1 1 6.8 1.9 4.1 1 6.5 1.9 3.3 1 5.7 0.4 48 17 42 255 15.4 0 16 15.5 07/16/2005 21:50:00 3.9 1 5.7 0.7 3.9 1 5.7 0.7 2.9 0.9 5.3 0.7 56 18 40 255 15.2 0.2 15.7 15.2 07/16/2005 22:00:00 3.9 0.9 6.5 1.9 3.9 1 6.5 1.9 2.9 1 5.3 0.4 63 17 83 255 15 0 15.5 14.9 07/16/2005 22:10:00 3.7 1 6.5 1.5 3.7 1.1 6.8 0.4 2.7 1 5.7 0.4 67 16 74 255 14.9 0 15.5 14.6 07/16/2005 22:20:00 2.8 0.7 4.2 0.7 2.9 0.7 4.6 1.1 2.1 0.8 4.2 0.4 76 17 61 255 14.6 0 15.2 14.6 07/16/2005 22:30:00 3.2 0.7 5.3 1.5 3.2 0.7 5.3 1.5 2.6 0.8 4.2 0.4 67 12 62 255 14.5 0 14.9 14.4 07/16/2005 22:40:00 2.8 0.6 4.2 1.5 2.8 0.6 4.6 1.5 2 0.6 3.4 0.7 56 13 59 255 14.4 0 14.6 14.4 07/16/2005 22:50:00 2.5 0.5 4.2 1.5 2.4 0.5 4.2 1.1 1.6 0.6 3.4 0.4 62 20 38 255 14.1 0.1 14.6 13.5 07/16/2005 23:00:00 2.6 0.5 3.8 1.1 2.6 0.5 3.8 1.5 1.8 0.5 3 0.4 79 16 40 255 13.3 0.2 13.8 13 07/16/2005 23:10:00 3.1 0.6 4.2 1.5 3.1 0.6 4.6 1.5 2.3 0.6 3.8 1.1 50 12 66 255 13.3 0.1 13.5 13 07/16/2005 23:20:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.1 1.9 0.6 3.8 0.4 75 12 70 255 13.2 0.2 13.5 12.7 07/16/2005 23:30:00 2.8 0.5 4.2 1.9 2.8 0.5 4.2 1.9 1.9 0.6 3.4 0.4 72 11 69 255 12.8 0 13 12.7 07/16/2005 23:40:00 2.2 0.6 3.8 0.7 2.1 0.6 3.4 0.7 1.5 0.6 3 0.4 73 14 79 255 12.8 0 13.3 12.7 07/16/2005 23:50:00 2.2 0.5 3.4 0.4 2.1 0.5 3.4 0.7 1.3 0.5 3 0.4 96 12 100 255 12.7 0.1 12.7 12.5 07/17/2005 00:00:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.3 0.6 3 0.4 95 15 83 255 12.4 0 12.5 12.2 07/17/2005 00:10:00 2.1 0.6 3.8 0.7 2.1 0.7 4.2 0.4 1.4 0.8 3 0.4 85 11 83 255 12.5 0 12.5 12.2 07/17/2005 00:20:00 2.9 0.6 4.6 1.1 2.8 0.6 4.6 1.5 2 0.7 3.8 0.4 72 13 53 255 12.4 0 12.5 12.2 07/17/2005 00:30:00 3 0.7 4.9 1.1 3 0.8 4.9 1.1 2.3 0.7 4.2 0.4 67 12 66 255 12.7 0 12.7 12.5 07/17/2005 00:40:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 0.7 2.5 0.8 4.6 0.4 62 14 66 255 12.9 0.1 13 12.7 07/17/2005 00:50:00 2.8 0.6 4.6 1.1 2.8 0.7 4.2 1.1 2.1 0.6 3.4 0.7 37 14 43 255 13 0 13.3 12.7 07/17/2005 01:00:00 2.6 0.6 4.2 1.1 2.7 0.5 4.2 1.1 1.9 0.6 3.8 0.4 56 12 41 255 12.8 0 13 12.7 07/17/2005 01:10:00 2.8 0.8 4.6 1.1 2.8 0.7 4.9 1.1 2 0.7 3.8 0.4 55 17 66 255 12.8 0 12.7 12.7 07/17/2005 01:20:00 2.8 0.6 4.6 1.1 2.8 0.7 4.6 1.5 2.1 0.7 3.8 0.4 58 14 44 255 12.8 0 12.7 12.7 07/17/2005 01:30:00 2.7 0.8 5.3 0.4 2.6 0.9 5.3 0.7 1.8 0.9 4.2 0.4 48 17 34 255 12.7 0 12.7 12.7 07/17/2005 01:40:00 2.6 0.7 4.2 0.7 2.5 0.8 4.2 0.4 1.9 0.9 3.8 0.4 32 10 40 255 12.7 0.1 12.7 12.2 07/17/2005 01:50:00 1.6 0.5 2.6 0.4 1.6 0.5 3 0.4 0.9 0.5 2.6 0.4 58 13 42 255 11.9 0.2 12.5 11.7 07/17/2005 02:00:00 1.9 0.4 3 1.1 1.9 0.5 3.4 0.7 1 0.5 2.3 0.4 65 9 69 255 11.2 0.2 11.7 10.9 07/17/2005 02:10:00 2.2 0.5 3.4 1.1 2.1 0.5 3 0.7 1.4 0.5 3 0.4 55 12 64 255 10.9 0 11.1 10.9 07/17/2005 02:20:00 2.1 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.5 0.6 2.6 0.4 53 12 18 255 11.4 0.3 11.7 10.9 07/17/2005 02:30:00 1.7 0.5 2.6 0.4 1.6 0.5 3 0.4 1 0.5 2.6 0.4 45 9 49 255 11.7 0 11.9 11.7 07/17/2005 02:40:00 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.8 0.5 2.3 0.4 50 9 51 255 11.7 0 11.7 11.4 07/17/2005 02:50:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 53 9 52 255 11.4 0 11.7 11.4 07/17/2005 03:00:00 1.4 0.4 2.3 0.4 1.3 0.5 2.6 0.4 0.8 0.4 1.9 0.4 63 8 58 255 11.7 0 11.7 11.7 07/17/2005 03:10:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.4 1.9 0.4 63 7 51 255 11.6 0 11.7 11.4 07/17/2005 03:20:00 1.5 0.4 2.6 0.4 1.5 0.5 3 0.4 0.8 0.4 1.9 0.4 76 13 79 255 11.2 0 11.4 11.1 07/17/2005 03:30:00 1.4 0.3 1.9 0.4 1.3 0.3 2.3 0.4 0.5 0.3 1.9 0.4 70 7 58 255 11.1 0 11.1 10.9 07/17/2005 03:40:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.7 0.3 1.5 0.4 69 8 66 255 10.9 0 11.1 10.9 07/17/2005 03:50:00 1.9 0.4 2.6 0.4 1.9 0.4 2.6 0.4 1 0.4 1.9 0.4 78 10 91 255 10.9 0 11.1 10.9 07/17/2005 04:00:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.6 0.3 1.9 0.4 74 13 80 255 10.9 0 11.1 10.9 07/17/2005 04:10:00 1.6 0.3 2.6 0.7 1.5 0.3 2.6 0.7 0.6 0.3 1.5 0.4 111 10 115 255 10.9 0 11.1 10.9 07/17/2005 04:20:00 2 0.5 3 1.1 2 0.5 3.4 0.7 1.4 0.4 2.6 0.4 118 11 102 255 11.1 0 11.1 10.9 07/17/2005 04:30:00 1.8 0.6 3.4 0.4 1.8 0.6 3 0.4 0.9 0.6 2.3 0.4 114 10 115 255 11.1 0 11.4 11.1 07/17/2005 04:40:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.5 0.3 2.3 0.4 112 5 112 255 11.3 0 11.4 11.1 07/17/2005 04:50:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.6 0.3 1.5 0.4 105 4 109 255 11.3 0 11.4 11.4 07/17/2005 05:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 95 17 104 255 11.5 0 11.7 11.4 07/17/2005 05:10:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 61 1 62 255 11.6 0 11.7 11.7 07/17/2005 05:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 55 6 47 255 11.7 0 11.7 11.7 07/17/2005 05:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 61 4 59 255 11.8 0 11.9 11.7 07/17/2005 05:40:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 48 13 48 255 12.1 0 12.2 11.9 07/17/2005 05:50:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 78 10 74 255 12.3 0 12.5 12.2 07/17/2005 06:00:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 58 17 76 255 12.5 0 12.7 12.5 07/17/2005 06:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 41 4 67 255 12.7 0 12.7 12.5 07/17/2005 06:20:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 54 9 64 255 12.9 0 13 12.7 07/17/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 0 255 255 13.1 0 13.5 13 07/17/2005 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 0 61 255 13.3 0 13.8 13 07/17/2005 06:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 0 61 255 13.5 0.1 13.8 13.3 07/17/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 0 255 255 13.7 0.2 14.4 13.3 07/17/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 0 255 255 14 0.1 14.6 13.8 07/17/2005 07:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 89 32 124 255 14.1 0.2 14.6 13.8 07/17/2005 07:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 124 0 124 255 14.2 0 14.6 13.8 07/17/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 255 255 14.6 0.1 15.2 14.4 07/17/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 255 255 15.1 0.1 15.7 14.9 07/17/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 255 255 15.6 0 16 15.5 07/17/2005 08:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 214 58 255 255 16.1 0 16.6 16 07/17/2005 08:20:00 0.8 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 316 8 312 255 16.1 0 16.8 16 07/17/2005 08:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 348 30 11 255 16.1 0 16.8 16 07/17/2005 08:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 352 15 329 255 16.3 0.1 16.8 16.3 07/17/2005 08:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 342 11 358 255 16.4 0 16.8 16.3 07/17/2005 09:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 331 9 333 255 16.7 0 17.1 16.3 07/17/2005 09:10:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 13 14 19 255 16.8 0 17.4 16.8 07/17/2005 09:20:00 0.7 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 316 98 336 255 16.8 0 17.1 16.8 07/17/2005 09:30:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.7 0.5 2.3 0.4 13 86 19 255 17.3 0.1 17.4 16.8 07/17/2005 09:40:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 0.8 0.6 3 0.4 298 43 284 255 17.5 0 17.7 17.1 07/17/2005 09:50:00 1.1 0.7 3.4 0.4 1.1 0.6 3 0.4 1 0.7 3.4 0.4 250 26 284 255 17.5 0.2 18 17.1 07/17/2005 10:00:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 307 30 296 255 17.5 0 17.7 17.4 07/17/2005 10:10:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.5 2.6 0.4 348 24 22 255 18.1 0.3 18.5 17.7 07/17/2005 10:20:00 2.1 0.8 4.2 0.4 2 0.8 3.8 0.4 1.7 0.8 3.8 0.4 327 27 265 255 19.4 0.4 20.3 18.5 07/17/2005 10:30:00 2.1 0.9 3.8 0.4 2 0.8 3.8 0.4 1.7 0.9 4.2 0.4 316 20 316 255 19.5 0.1 20.3 19.4 07/17/2005 10:40:00 2.5 1.1 5.3 0.4 2.5 1 5.7 0.4 1.7 1 4.2 0.4 349 26 9 255 19.5 0.1 20.3 19.4 07/17/2005 10:50:00 2.9 0.8 4.2 0.4 2.8 0.8 4.6 0.4 1.9 1 4.2 0.4 358 36 0 255 19.7 0.1 20.3 19.4 07/17/2005 11:00:00 2.4 0.6 3.8 0.4 2.3 0.7 3.8 0.4 2.2 0.7 3.8 0.4 298 29 289 255 19.2 0.3 20 18.5 07/17/2005 11:10:00 2.1 0.8 4.2 0.4 1.9 0.9 3.8 0.4 1.6 0.8 3.4 0.4 333 49 349 255 20.3 0.9 21.7 18.5 07/17/2005 11:20:00 2.7 0.9 4.6 0.4 2.6 0.8 4.6 0.4 2.1 0.8 4.2 0.4 325 30 338 255 21.9 0.1 22.6 21.7 07/17/2005 11:30:00 2.2 1.3 6.1 0.4 2.1 1.3 6.1 0.4 1.7 1.2 4.9 0.4 296 27 279 255 19.9 0.9 21.7 18.8 07/17/2005 11:40:00 1.4 0.9 3.8 0.4 1.4 0.9 3.8 0.4 1.2 0.8 3.4 0.4 260 39 291 255 18.4 0 18.8 18.2 07/17/2005 11:50:00 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1 0.7 4.2 0.4 241 36 306 255 18.4 0 18.8 18.2 07/17/2005 12:00:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 249 36 276 255 18.6 0.1 19.1 18.2 07/17/2005 12:10:00 2.2 0.9 4.6 0.4 2.1 0.9 4.6 0.4 1.7 1 4.2 0.4 316 22 303 255 19.6 0.9 21.1 18.5 07/17/2005 12:20:00 2.7 0.8 4.9 0.7 2.6 0.9 4.9 0.7 2.4 1 5.3 0.4 298 28 288 255 21 0.2 21.7 20.5 07/17/2005 12:30:00 1.8 1 3.8 0.4 1.8 1 3.8 0.4 1.6 1 3.8 0.4 315 56 345 255 21.9 0 22.3 21.4 07/17/2005 12:40:00 2 0.8 3.8 0.4 1.9 0.9 3.8 0.4 1.5 0.7 3 0.4 316 51 326 255 22.4 0.1 22.9 22.3 07/17/2005 12:50:00 2.2 1 4.2 0.4 2.1 0.9 4.2 0.4 1.9 0.9 4.2 0.4 358 18 8 255 23 0.2 23.5 22.6 07/17/2005 13:00:00 1.5 0.9 3.8 0.4 1.4 0.9 3.8 0.4 1.2 0.8 3.4 0.4 336 33 322 255 22.1 0.4 22.9 21.1 07/17/2005 13:10:00 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.7 0.6 2.3 0.4 272 107 325 255 21 0.2 21.4 20.8 07/17/2005 13:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 138 30 113 255 20.5 0 20.8 20 07/17/2005 13:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 246 79 178 255 19.8 0.1 20.3 19.4 07/17/2005 13:40:00 2.2 1.2 5.3 0.4 2.2 1.2 5.3 0.4 2 1.1 4.6 0.4 258 26 307 255 17.8 1 19.4 16.3 07/17/2005 13:50:00 2.5 0.9 4.9 0.7 2.5 0.9 4.9 0.7 2 0.9 4.9 0.4 246 22 194 255 15.9 0.2 16.8 15.7 07/17/2005 14:00:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 0.7 2 0.8 4.6 0.4 274 22 296 255 15.6 0 16.3 15.5 07/17/2005 14:10:00 2.1 0.4 3 1.1 2.1 0.5 3 1.1 1.5 0.4 2.6 0.4 258 10 256 255 15.5 0 15.7 15.5 07/17/2005 14:20:00 1.6 0.5 3 0.7 1.7 0.6 3 0.7 1.4 0.5 2.6 0.4 214 22 207 255 15.3 0 15.5 15.2 07/17/2005 14:30:00 1.5 0.5 2.6 0.7 1.6 0.5 3 0.4 1 0.5 2.3 0.4 182 17 195 255 15.5 0 15.7 15.5 07/17/2005 14:40:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 186 17 163 255 15.6 0 16 15.5 07/17/2005 14:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 166 3 176 255 16 0 16.3 15.7 07/17/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 161 3 255 255 16.4 0 16.6 16.3 07/17/2005 15:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 159 0 159 255 16.8 0.2 17.1 16.6 07/17/2005 15:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 105 41 66 255 17.8 0.2 18.2 17.1 07/17/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 23 255 255 18.8 0.5 19.4 18 07/17/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 132 2 255 255 19.2 0.1 20 18.8 07/17/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 36 255 255 19 0.1 19.4 18.5 07/17/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 18.7 0.2 19.4 18.5 07/17/2005 16:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 355 15 349 255 19 0.3 20 18.5 07/17/2005 16:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 352 13 2 255 19.7 0.1 20.3 19.4 07/17/2005 16:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 17 79 274 255 20.3 0.3 20.8 19.7 07/17/2005 16:40:00 1.3 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1 0.5 2.6 0.4 309 22 303 255 20.6 0.1 21.1 20.3 07/17/2005 16:50:00 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.8 0.5 2.3 0.4 334 23 307 255 20.4 0 20.5 20.3 07/17/2005 17:00:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 359 24 356 255 20.6 0.1 21.1 20.5 07/17/2005 17:10:00 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.9 0.6 2.6 0.4 327 23 297 255 20.4 0 20.8 20.3 07/17/2005 17:20:00 2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.5 0.9 3.4 0.4 303 12 297 255 20.3 0.1 20.8 20 07/17/2005 17:30:00 2.5 1.2 5.3 0.4 2.4 1.3 5.3 0.4 1.9 1.3 4.9 0.4 289 24 277 255 19.9 0 20.3 19.7 07/17/2005 17:40:00 2.5 0.8 4.6 0.4 2.4 0.8 4.6 0.4 1.8 0.8 3.8 0.4 250 30 256 255 20 0 20.3 20 07/17/2005 17:50:00 2.2 0.9 4.9 0.4 2.1 0.9 4.9 0.4 1.6 1 3.8 0.4 254 30 287 255 20 0 20.3 20 07/17/2005 18:00:00 2.4 0.7 4.2 0.4 2.3 0.7 4.2 0.4 1.9 0.8 3.8 0.4 274 28 308 255 20 0 20.5 20 07/17/2005 18:10:00 2.4 1.1 4.9 0.7 2.2 1.1 4.9 0.4 1.8 1 4.6 0.4 285 22 307 255 20 0.1 20.5 19.7 07/17/2005 18:20:00 2.3 0.9 4.6 0.4 2.3 1 4.6 0.4 1.6 0.9 4.6 0.4 268 26 277 255 19.6 0 19.7 19.4 07/17/2005 18:30:00 3.1 1 5.7 1.1 3.1 1 5.7 1.1 2.5 1 6.1 0.7 271 19 280 255 19.3 0 19.7 19.1 07/17/2005 18:40:00 2.7 1.1 4.9 0.4 2.6 1 4.6 0.4 2.1 1 4.6 0.4 280 27 286 255 19.1 0 19.4 18.8 07/17/2005 18:50:00 2.6 0.9 4.9 0.4 2.6 0.9 4.6 0.4 1.9 0.9 4.2 0.4 272 19 253 255 18.7 0.1 19.4 18.5 07/17/2005 19:00:00 2.1 1 4.6 0.4 2.1 1 4.6 0.4 1.4 0.9 3.8 0.4 268 17 258 255 18.5 0.1 19.1 18.2 07/17/2005 19:10:00 2.5 0.9 4.9 0.4 2.4 1 4.9 0.4 1.9 0.8 4.2 0.4 273 23 256 255 18.4 0.1 19.1 18.2 07/17/2005 19:20:00 1.6 0.8 3.4 0.4 1.5 0.8 3.8 0.4 1 0.7 3.4 0.4 279 27 256 255 18.5 0 19.1 18.5 07/17/2005 19:30:00 1.9 0.7 3.8 0.4 1.8 0.7 4.2 0.4 1.4 0.7 3.4 0.4 284 16 291 255 18.6 0 19.1 18.5 07/17/2005 19:40:00 1.9 0.6 3.8 0.4 1.8 0.7 3.4 0.4 1 0.6 3 0.4 274 22 282 255 18.5 0.1 19.1 18.2 07/17/2005 19:50:00 3.2 0.8 5.7 1.5 3.1 0.8 5.7 0.7 2.2 0.8 4.2 0.4 266 18 291 255 18.5 0 19.1 18.2 07/17/2005 20:00:00 2.3 0.7 3.8 0.4 2.2 0.7 3.8 0.4 1.6 0.7 3.4 0.4 277 17 268 255 18.3 0 18.5 18 07/17/2005 20:10:00 2 0.7 3.8 0.4 1.9 0.8 3.4 0.4 1.3 0.8 3 0.4 274 15 265 255 18 0 18.2 17.7 07/17/2005 20:20:00 1.9 0.7 3.8 0.4 1.9 0.8 4.2 0.4 1.2 0.7 3.8 0.4 277 22 273 255 17.6 0 18 17.4 07/17/2005 20:30:00 2.3 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.3 0.7 3.4 0.4 263 22 279 255 17.3 0 17.4 17.1 07/17/2005 20:40:00 1.7 0.6 3.8 0.7 1.6 0.6 3.4 0.4 0.9 0.6 2.6 0.4 267 13 262 255 17 0.1 17.1 16.8 07/17/2005 20:50:00 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 0.8 0.6 3 0.4 265 15 289 255 16.5 0.1 16.8 16.3 07/17/2005 21:00:00 0.7 0.5 2.6 0.4 0.6 0.4 2.6 0.4 0.4 0.1 1.1 0.4 309 27 268 255 16.1 0 16.6 16 07/17/2005 21:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 334 32 351 255 15.8 0 16 15.7 07/17/2005 21:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 359 5 356 255 15.6 0 16 15.5 07/17/2005 21:30:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 37 7 40 255 15.5 0 15.7 15.5 07/17/2005 21:40:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.1 0.7 0.4 24 9 29 255 15.4 0 15.7 15.2 07/17/2005 21:50:00 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.1 0.7 0.4 18 9 13 255 15.2 0.1 15.7 15.2 07/17/2005 22:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 42 13 43 255 15.1 0.1 15.7 14.9 07/17/2005 22:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 20 0 20 255 15 0 15.7 14.9 07/17/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 20 0 255 255 15 0 15.5 14.9 07/17/2005 22:30:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 46 23 64 255 14.9 0 15.5 14.9 07/17/2005 22:40:00 1 0.2 1.5 0.4 0.8 0.2 1.5 0.4 0.4 0.1 1.1 0.4 94 20 71 255 14.7 0 15.2 14.6 07/17/2005 22:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 120 0 120 255 14.6 0 14.9 14.6 07/17/2005 23:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 118 8 120 255 14.4 0 14.6 14.4 07/17/2005 23:10:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 67 8 75 255 14.2 0.2 14.9 13.8 07/17/2005 23:20:00 1.3 0.5 2.3 0.4 1.2 0.6 2.3 0.4 0.8 0.5 1.9 0.4 44 8 59 255 14 0.2 14.6 13.8 07/17/2005 23:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 35 0 35 255 13.8 0 14.1 13.5 07/17/2005 23:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 46 4 35 255 13.8 0 14.1 13.5 07/17/2005 23:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 48 255 13.8 0 14.1 13.5 07/18/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 13.9 0 14.4 13.5 07/18/2005 00:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 47 255 13.9 0 14.4 13.5 07/18/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 13.7 0.1 14.1 13.5 07/18/2005 00:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 47 255 13.7 0 14.1 13.5 07/18/2005 00:40:00 1.2 0.5 1.9 0.4 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 67 16 71 255 13.5 0.1 14.1 13.5 07/18/2005 00:50:00 1.1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.2 1.5 0.4 87 5 86 255 13.5 0.1 13.8 13.3 07/18/2005 01:00:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.7 0.4 92 9 100 255 13.4 0 13.8 13.3 07/18/2005 01:10:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.7 0.4 106 6 112 255 13.4 0 13.8 13.3 07/18/2005 01:20:00 1.4 0.3 2.3 0.4 1.2 0.4 1.9 0.4 0.5 0.2 1.5 0.4 108 7 95 255 13.4 0 13.8 13.3 07/18/2005 01:30:00 1.4 0.3 2.3 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 110 5 113 255 13.4 0 13.8 13.3 07/18/2005 01:40:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.4 0 0.7 0.4 112 2 111 255 13.3 0 13.8 13.3 07/18/2005 01:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 120 6 112 255 13.3 0 13.5 13.3 07/18/2005 02:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 124 0 124 255 13.4 0 13.5 13.3 07/18/2005 02:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 124 255 13.4 0 13.8 13.3 07/18/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 255 255 13.4 0 13.5 13.3 07/18/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 255 255 13.4 0 13.5 13.3 07/18/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 255 255 13.3 0 13.5 13.3 07/18/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 11 255 255 13.3 0 13.5 13.3 07/18/2005 03:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 7 201 255 13.3 0 13.5 13.3 07/18/2005 03:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 286 90 23 255 13.3 0 13.3 13.3 07/18/2005 03:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 23 0 23 255 13.2 0 13.3 13 07/18/2005 03:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 12 5 23 255 13.1 0 13.5 13 07/18/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 13.1 0 13.3 13 07/18/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 13.1 0 13.5 13 07/18/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 13.1 0 13.5 13 07/18/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 13.1 0 13.5 13 07/18/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 13.1 0 13.5 13 07/18/2005 04:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 22 15 40 255 13.3 0 13.8 13 07/18/2005 04:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 40 255 13.3 0 13.8 13.3 07/18/2005 04:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 39 122 255 13.3 0 13.5 13.3 07/18/2005 05:00:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 136 2 136 255 13.3 0 13.5 13.3 07/18/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 13.4 0 13.8 13.3 07/18/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 13.4 0.1 13.8 13.3 07/18/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 13.6 0.1 14.1 13.3 07/18/2005 05:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 137 30 119 255 13.8 0 14.4 13.5 07/18/2005 05:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 128 10 118 255 13.9 0 14.6 13.8 07/18/2005 06:00:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.6 2.3 0.4 124 8 115 255 14.2 0 14.6 14.1 07/18/2005 06:10:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 134 1 133 255 14.4 0 14.9 14.4 07/18/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 0 255 255 14.6 0.1 15.2 14.6 07/18/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 0 255 255 14.8 0 15.5 14.6 07/18/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 39 255 255 15 0 15.5 14.9 07/18/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 357 8 1 255 15 0 15.5 14.9 07/18/2005 07:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 1 255 15 0 15.2 14.9 07/18/2005 07:10:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1 0 1 255 15 0 15.2 14.9 07/18/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 0 255 255 15 0 15.2 14.9 07/18/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 255 255 15 0 15.2 15.2 07/18/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 255 255 15 0 15.5 15.2 07/18/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 255 255 15.2 0 15.5 15.2 07/18/2005 08:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 0 255 15.5 0 15.7 15.2 07/18/2005 08:10:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 296 23 321 255 15.5 0 16 15.5 07/18/2005 08:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 282 21 308 255 15.6 0 16 15.5 07/18/2005 08:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 291 9 279 255 15.7 0.1 16.3 15.7 07/18/2005 08:40:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 266 10 258 255 16 0.1 16.6 15.7 07/18/2005 08:50:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 260 14 280 255 16.1 0 16.6 16 07/18/2005 09:00:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 270 15 260 255 16.4 0 16.8 16.3 07/18/2005 09:10:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.6 2.6 0.4 291 17 291 255 16.5 0 16.8 16.3 07/18/2005 09:20:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.6 0.4 277 32 240 255 17.1 0.1 17.7 16.8 07/18/2005 09:30:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 0.8 0.6 2.6 0.4 233 23 240 255 17.3 0 17.7 17.1 07/18/2005 09:40:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 242 19 240 255 17.2 0 17.4 17.1 07/18/2005 09:50:00 1.1 0.6 2.6 0.4 1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 243 17 262 255 17.1 0 17.1 16.8 07/18/2005 10:00:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.7 0.4 2.3 0.4 239 22 279 255 17.1 0 17.1 16.8 07/18/2005 10:10:00 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 1.1 0.6 3 0.4 238 28 189 255 17.5 0.4 18.5 17.1 07/18/2005 10:20:00 1.1 0.8 3 0.4 1 0.8 3 0.4 1 0.7 3.4 0.4 298 64 307 255 18.7 0 19.1 18.5 07/18/2005 10:30:00 1.3 0.8 3 0.4 1.2 0.8 3.4 0.4 1.1 0.7 2.6 0.4 316 51 274 255 18.5 0.1 19.1 18.2 07/18/2005 10:40:00 1.5 0.7 3.4 0.4 1.4 0.7 3 0.4 1.3 0.7 2.6 0.4 295 22 313 255 18.2 0 18.8 18 07/18/2005 10:50:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.6 0.7 3.4 0.4 301 28 298 255 18.7 0.4 20 18.2 07/18/2005 11:00:00 2.8 1.1 5.3 0.4 2.7 1.2 4.9 0.4 2.1 1.3 4.9 0.4 286 27 291 255 19.3 0.2 20.3 18.8 07/18/2005 11:10:00 3.4 0.9 6.1 0.7 3.3 0.9 5.7 0.7 2.6 1 5.3 0.4 279 22 306 255 18.5 0.2 19.1 17.7 07/18/2005 11:20:00 2.2 1 5.3 0.4 2.1 1 5.7 0.4 1.7 1 4.2 0.4 253 29 247 255 17.8 0 18.2 17.7 07/18/2005 11:30:00 1.7 1.2 4.9 0.4 1.8 1.2 4.6 0.4 1.3 1 4.2 0.4 262 45 253 255 17.9 0 18.5 17.7 07/18/2005 11:40:00 2.4 1 5.3 0.4 2.3 1 5.3 0.4 1.8 1 4.6 0.4 280 30 290 255 18.2 0 18.8 18 07/18/2005 11:50:00 2.9 0.8 5.3 1.1 2.9 0.8 4.9 1.1 2.4 0.8 4.2 0.4 278 18 252 255 18.2 0 18.5 18 07/18/2005 12:00:00 2.7 1.1 4.9 0.4 2.6 1.2 4.6 0.4 2.2 1.1 4.9 0.4 273 32 325 255 18.4 0.2 19.1 18 07/18/2005 12:10:00 3.3 0.7 4.9 1.5 3.3 0.8 4.9 1.1 2.9 0.8 4.6 0.7 287 20 286 255 18.6 0 19.1 18.5 07/18/2005 12:20:00 2.1 0.8 4.6 0.4 2 0.9 4.6 0.4 1.7 1 4.2 0.4 280 30 271 255 18.7 0 19.4 18.5 07/18/2005 12:30:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1.1 0.8 3 0.4 256 51 293 255 19.2 0 19.7 18.8 07/18/2005 12:40:00 2.1 0.9 4.6 0.4 1.9 0.9 4.6 0.4 1.8 0.9 4.2 0.4 255 24 259 255 19 0.2 19.4 18.2 07/18/2005 12:50:00 2.7 0.9 4.6 0.4 2.6 0.9 4.6 0.4 2.1 0.9 4.2 0.4 253 23 233 255 18.4 0 18.8 18.2 07/18/2005 13:00:00 3.1 0.7 4.9 1.5 3 0.6 4.9 1.5 2.3 0.8 4.2 0.7 263 18 257 255 18 0.1 18.8 17.7 07/18/2005 13:10:00 2.3 0.7 3.8 0.4 2.1 0.7 3.4 0.4 1.7 0.9 3.8 0.4 282 24 260 255 17.8 0 18.2 17.7 07/18/2005 13:20:00 1.9 1 3.8 0.4 1.7 1 3.8 0.4 1.4 1 3.8 0.4 278 27 275 255 17.8 0 18.2 17.7 07/18/2005 13:30:00 2.3 0.6 4.2 0.7 2.2 0.7 4.2 0.4 2 0.7 3.8 0.4 285 22 321 255 18 0 18.5 17.7 07/18/2005 13:40:00 2.5 0.8 4.2 0.7 2.4 0.9 4.2 0.4 2.1 0.8 3.8 0.4 279 23 257 255 18 0 18.5 18 07/18/2005 13:50:00 3 1 4.9 0.4 2.9 1 4.9 0.7 2.2 1 5.3 0.4 283 22 262 255 17.9 0 18.5 17.7 07/18/2005 14:00:00 2.5 0.7 4.2 0.4 2.3 0.8 4.2 0.4 2 0.8 3.8 0.4 282 15 275 255 17.5 0.1 17.7 17.4 07/18/2005 14:10:00 2.3 0.7 3.8 0.7 2.2 0.7 3.8 0.7 1.7 0.8 3.4 0.4 303 19 291 255 17.6 0 17.7 17.4 07/18/2005 14:20:00 1.7 0.6 3 0.4 1.7 0.6 3.4 0.4 1.3 0.7 3 0.4 302 13 267 255 17.8 0 18 17.4 07/18/2005 14:30:00 1.4 0.7 3.4 0.4 1.3 0.7 3.4 0.4 1.2 0.6 2.6 0.4 298 15 304 255 17.9 0 18 17.7 07/18/2005 14:40:00 1.7 0.5 3 0.4 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 300 16 314 255 17.8 0 18 17.7 07/18/2005 14:50:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.3 0.4 287 15 337 255 17.8 0 17.7 17.4 07/18/2005 15:00:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.6 0.4 325 16 328 255 18.1 0.2 18.5 17.7 07/18/2005 15:10:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 1 0.5 2.6 0.4 294 41 315 255 18.6 0 18.8 18.5 07/18/2005 15:20:00 1.3 0.6 3 0.4 1.1 0.7 3 0.4 0.9 0.6 2.6 0.4 320 33 301 255 18.7 0 19.1 18.5 07/18/2005 15:30:00 1.5 0.8 3 0.4 1.3 0.9 3 0.4 1.1 0.9 3 0.4 325 35 309 255 19 0 19.1 18.5 07/18/2005 15:40:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 313 14 295 255 18.3 0 18.5 18.2 07/18/2005 15:50:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.5 2.3 0.4 317 15 314 255 18.2 0 18.2 18 07/18/2005 16:00:00 1.8 0.9 4.2 0.4 1.7 1 4.2 0.4 1.3 0.7 3.8 0.4 308 13 317 255 18.2 0 18.2 18 07/18/2005 16:10:00 2.2 0.7 4.2 0.4 2.1 0.8 4.2 0.4 1.6 0.8 3.4 0.4 295 20 288 255 17.9 0 18.2 17.7 07/18/2005 16:20:00 1.8 0.9 4.6 0.4 1.7 1 4.6 0.4 1.3 0.9 4.2 0.4 297 24 291 255 17.6 0 17.7 17.4 07/18/2005 16:30:00 2.6 0.8 4.6 0.4 2.5 0.8 4.6 0.4 2.1 0.9 4.2 0.4 294 18 282 255 17.4 0 17.4 17.1 07/18/2005 16:40:00 1.4 0.7 3 0.4 1.3 0.8 3 0.4 1 0.7 3 0.4 293 22 279 255 17.3 0 17.4 17.1 07/18/2005 16:50:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 301 17 287 255 17.6 0 18 17.1 07/18/2005 17:00:00 1.5 0.7 3.4 0.4 1.4 0.7 3 0.4 1.2 0.7 2.6 0.4 303 28 281 255 18.2 0 18.5 17.7 07/18/2005 17:10:00 2.2 0.8 4.2 0.4 2.1 0.8 3.8 0.4 2 0.9 4.2 0.4 300 19 298 255 18.3 0 18.5 18 07/18/2005 17:20:00 2 1 4.2 0.4 1.8 1 4.2 0.4 1.5 1 4.6 0.4 317 17 298 255 18 0 18.2 17.7 07/18/2005 17:30:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.4 0.6 3 0.4 307 21 294 255 17.8 0 18 17.7 07/18/2005 17:40:00 2 0.5 3 0.7 1.9 0.5 3 0.4 1.2 0.7 2.6 0.4 7 13 20 255 17.6 0 17.7 17.4 07/18/2005 17:50:00 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.5 2.2 0.7 3.8 0.7 30 16 45 255 17.2 0 17.7 16.8 07/18/2005 18:00:00 1.9 0.5 3 0.7 1.8 0.5 3 0.4 1.3 0.6 2.6 0.4 22 17 8 255 16.8 0 17.1 16.8 07/18/2005 18:10:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.1 0.6 2.3 0.4 21 17 18 255 16.7 0 17.1 16.8 07/18/2005 18:20:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.3 0.6 2.6 0.4 27 12 36 255 16.7 0 17.1 16.8 07/18/2005 18:30:00 1.5 0.4 2.3 0.7 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 27 12 20 255 16.9 0 17.4 16.8 07/18/2005 18:40:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.2 0.4 2.3 0.4 27 9 7 255 17.1 0 17.4 16.8 07/18/2005 18:50:00 1.4 0.4 2.3 0.7 1.2 0.4 2.3 0.4 1.1 0.5 2.3 0.4 18 7 31 255 17 0 17.4 16.8 07/18/2005 19:00:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 20 9 12 255 17 0 17.4 16.8 07/18/2005 19:10:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.5 1.9 0.4 28 17 40 255 17.1 0 17.7 16.8 07/18/2005 19:20:00 1.6 0.4 2.6 0.4 1.5 0.5 2.3 0.4 1.2 0.6 2.6 0.4 32 13 27 255 17.1 0 17.7 16.8 07/18/2005 19:30:00 1.5 0.4 2.6 0.4 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 42 14 16 255 16.8 0 17.4 16.6 07/18/2005 19:40:00 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.3 0.4 1.9 0.4 49 8 48 255 16.5 0.1 17.1 16.3 07/18/2005 19:50:00 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.9 0.5 1.9 0.4 65 14 55 255 16.2 0 16.8 16.3 07/18/2005 20:00:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 54 15 74 255 16 0 16.6 16 07/18/2005 20:10:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 35 13 28 255 15.9 0 16.3 15.7 07/18/2005 20:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 46 13 38 255 15.7 0 16.3 15.7 07/18/2005 20:30:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 39 10 59 255 15.5 0 16.3 15.5 07/18/2005 20:40:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 60 12 35 255 15.3 0 16 15.2 07/18/2005 20:50:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 90 23 124 255 15.2 0.1 15.7 15.2 07/18/2005 21:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 69 18 88 255 15 0 15.5 14.9 07/18/2005 21:10:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 64 16 48 255 14.9 0 15.5 14.9 07/18/2005 21:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 73 4 66 255 14.8 0 15.5 14.9 07/18/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 255 255 14.8 0 15.2 14.9 07/18/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 255 255 14.7 0 15.5 14.6 07/18/2005 21:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 48 47 284 255 14.6 0 14.9 14.6 07/18/2005 22:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 249 2 248 255 14.6 0 15.2 14.6 07/18/2005 22:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 254 20 250 255 14.7 0.1 15.2 14.6 07/18/2005 22:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 352 6 336 255 14.6 0 15.2 14.6 07/18/2005 22:30:00 1.3 0.5 1.9 0.4 1.1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 6 9 355 255 14.5 0 14.9 14.4 07/18/2005 22:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 10 13 19 255 14.5 0 14.9 14.4 07/18/2005 22:50:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.1 0.4 1.9 0.4 26 11 20 255 14.3 0 14.9 14.4 07/18/2005 23:00:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.5 1.9 0.4 37 15 43 255 14.2 0 14.9 14.1 07/18/2005 23:10:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 38 9 36 255 14.2 0.1 14.6 14.1 07/18/2005 23:20:00 0.7 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 47 17 36 255 14.2 0.2 14.6 14.1 07/18/2005 23:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 31 17 34 255 14.2 0.2 14.6 14.1 07/18/2005 23:40:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 38 19 71 255 14.2 0.2 14.6 14.1 07/18/2005 23:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 14.2 0.1 14.6 14.1 07/19/2005 00:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 14.2 0.2 14.6 14.1 07/19/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 255 255 14.3 0.2 14.6 14.1 07/19/2005 00:20:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 111 32 129 255 14.2 0.2 14.6 14.1 07/19/2005 00:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 115 2 129 255 14.2 0 14.6 14.1 07/19/2005 00:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 111 5 115 255 14.3 0 14.6 14.4 07/19/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 255 255 14.4 0 14.6 14.4 07/19/2005 01:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 104 255 14.3 0 14.6 14.4 07/19/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 9 255 255 14.2 0 14.6 14.4 07/19/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 255 255 14.3 0 14.6 14.1 07/19/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 255 255 14.2 0 14.6 14.4 07/19/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 255 255 14.2 0 14.6 14.4 07/19/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 255 255 14.3 0.1 14.6 14.4 07/19/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 255 255 14.3 0 14.6 14.4 07/19/2005 02:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 64 243 255 14.3 0.1 14.6 14.4 07/19/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 184 15 177 255 14.4 0 14.9 14.4 07/19/2005 02:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 169 29 147 255 14.4 0 14.9 14.4 07/19/2005 02:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 201 8 209 255 14.5 0 14.9 14.4 07/19/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 0 255 255 14.5 0 14.9 14.4 07/19/2005 03:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 0 192 255 14.5 0 14.9 14.4 07/19/2005 03:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 75 86 1 255 14.5 0 14.9 14.4 07/19/2005 03:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 6 4 355 255 14.4 0 14.9 14.4 07/19/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 255 255 14.2 0 14.6 14.1 07/19/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 255 255 14.2 0.1 14.6 14.1 07/19/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 255 255 14.2 0.1 14.6 14.1 07/19/2005 04:00:00 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.4 1.9 0.4 10 4 20 255 14.2 0.1 14.6 14.1 07/19/2005 04:10:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 16 0 16 255 13.9 0 14.6 13.8 07/19/2005 04:20:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.6 0.4 2.6 0.4 16 3 0 255 13.8 0 14.4 13.5 07/19/2005 04:30:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 1.5 0.5 3 0.4 22 6 13 255 13.5 0 13.8 13.3 07/19/2005 04:40:00 2 0.4 3 1.1 1.9 0.4 3 1.1 1.5 0.5 2.6 0.4 37 11 26 255 13.2 0 13.8 13 07/19/2005 04:50:00 2 0.4 3.4 1.1 2 0.4 3.4 0.7 1.5 0.5 2.6 0.4 43 13 60 255 12.9 0 13.3 12.7 07/19/2005 05:00:00 1.6 0.4 2.3 0.7 1.6 0.4 2.6 0.4 0.9 0.5 2.3 0.4 50 12 40 255 12.8 0 12.7 12.7 07/19/2005 05:10:00 1.7 0.5 3 0.4 1.7 0.5 2.6 0.4 1.1 0.6 2.3 0.4 44 12 45 255 12.7 0 12.7 12.7 07/19/2005 05:20:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 51 15 50 255 12.7 0 12.7 12.5 07/19/2005 05:30:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.2 0.5 2.6 0.4 49 11 10 255 12.7 0 12.7 12.5 07/19/2005 05:40:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 50 13 49 255 12.7 0 12.7 12.5 07/19/2005 05:50:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 53 12 44 255 12.7 0 12.7 12.7 07/19/2005 06:00:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.9 0.5 1.9 0.4 46 7 36 255 12.8 0 12.7 12.7 07/19/2005 06:10:00 1.9 0.5 3 0.7 1.9 0.5 3 0.4 1.3 0.6 2.6 0.4 43 12 36 255 12.8 0 12.7 12.7 07/19/2005 06:20:00 2 0.6 3 0.4 1.9 0.6 3.4 0.4 1.5 0.7 3.4 0.4 46 13 49 255 12.8 0 12.7 12.7 07/19/2005 06:30:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 44 12 29 255 12.8 0 13 12.7 07/19/2005 06:40:00 1.7 0.7 3 0.4 1.6 0.8 3.4 0.4 1.3 0.7 3 0.4 50 12 42 255 13.1 0 13.3 12.7 07/19/2005 06:50:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.8 0.5 2.3 0.4 48 13 43 255 13.3 0 13.5 13.3 07/19/2005 07:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.9 0.4 60 14 40 255 13.5 0 13.5 13.3 07/19/2005 07:10:00 0.5 0.3 1.9 0.4 0.4 0.3 1.5 0.4 0.4 0.1 1.1 0.4 60 17 72 255 13.7 0 14.4 13.5 07/19/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 4 61 255 13.7 0.1 14.4 13.5 07/19/2005 07:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 66 4 68 255 13.9 0 14.4 13.5 07/19/2005 07:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 41 15 61 255 14 0.1 14.6 13.8 07/19/2005 07:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 24 9 11 255 14.2 0 14.6 14.1 07/19/2005 08:00:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 15 5 22 255 14.2 0 14.9 14.1 07/19/2005 08:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.7 0.4 358 18 341 255 14.2 0 14.6 14.1 07/19/2005 08:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 343 12 322 255 14.2 0.1 14.6 14.1 07/19/2005 08:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 345 11 334 255 14.1 0.1 14.6 14.1 07/19/2005 08:40:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 33 15 51 255 14.1 0.1 14.6 13.8 07/19/2005 08:50:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 52 7 48 255 14.2 0 14.6 14.1 07/19/2005 09:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 57 16 54 255 14.5 0 14.9 14.4 07/19/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 0 255 255 14.6 0.2 15.2 14.6 07/19/2005 09:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 84 2 86 255 15 0.2 15.7 14.9 07/19/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 4 255 255 15.2 0.1 15.7 15.2 07/19/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 0 255 255 15.7 0.1 16.3 15.5 07/19/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 15 255 255 16 0 16.6 16 07/19/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 319 61 255 255 16.1 0 16.8 16.3 07/19/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 255 255 16.5 0 16.8 16.3 07/19/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 255 255 17.1 0.2 17.7 16.8 07/19/2005 10:30:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 341 47 23 255 17.7 0.1 18.2 17.1 07/19/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 29 64 255 255 17.3 0 17.4 17.1 07/19/2005 10:50:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 325 49 0 255 17.5 0.1 18 17.1 07/19/2005 11:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 352 11 350 255 17.3 0 17.7 17.1 07/19/2005 11:10:00 0.9 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.4 1.9 0.4 339 21 321 255 17.1 0 17.4 16.8 07/19/2005 11:20:00 1.4 0.4 2.3 0.4 1.3 0.4 1.9 0.4 1.1 0.5 2.3 0.4 310 10 307 255 17.1 0 17.4 16.8 07/19/2005 11:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 298 19 329 255 17 0 17.4 16.8 07/19/2005 11:40:00 1.8 0.3 2.6 1.1 1.7 0.4 2.6 1.1 1.6 0.6 2.6 0.4 306 5 318 255 17.3 0.1 17.7 17.1 07/19/2005 11:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 290 24 323 255 17.6 0 17.7 17.4 07/19/2005 12:00:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 354 17 0 255 17.5 0 17.7 17.4 07/19/2005 12:10:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 339 18 358 255 17.6 0 17.7 17.4 07/19/2005 12:20:00 1.5 0.4 2.6 0.4 1.3 0.4 2.6 0.4 1.3 0.6 3.4 0.4 332 16 328 255 17.6 0 17.7 17.4 07/19/2005 12:30:00 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1 0.7 2.6 0.4 327 12 312 255 17.3 0.1 17.7 17.1 07/19/2005 12:40:00 0.9 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.3 1.5 0.4 328 22 296 255 17.5 0 17.7 17.1 07/19/2005 12:50:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.6 0.4 309 20 329 255 17.6 0 17.7 17.4 07/19/2005 13:00:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 303 15 315 255 17.6 0 17.7 17.4 07/19/2005 13:10:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.8 0.5 1.9 0.4 289 17 320 255 17.7 0 18 17.4 07/19/2005 13:20:00 1.4 0.6 2.6 0.4 1.1 0.6 3 0.4 0.7 0.5 2.6 0.4 321 26 324 255 17.3 0 17.4 17.1 07/19/2005 13:30:00 1.8 0.6 3 0.4 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 314 28 317 255 17.3 0 17.4 17.1 07/19/2005 13:40:00 1.4 0.7 3 0.4 1.3 0.7 2.6 0.4 1.3 0.7 3 0.4 291 16 314 255 17.3 0 17.7 17.1 07/19/2005 13:50:00 1.4 0.6 2.3 0.4 1 0.5 2.3 0.4 1 0.6 2.6 0.4 329 15 316 255 17.5 0 17.7 17.1 07/19/2005 14:00:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.6 2.6 0.4 315 22 326 255 17.4 0.1 17.7 16.8 07/19/2005 14:10:00 1.6 0.4 2.6 0.4 1.5 0.4 2.3 0.4 1.4 0.5 2.6 0.4 312 7 311 255 17.3 0 17.4 17.1 07/19/2005 14:20:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.2 0.5 2.3 0.4 312 15 324 255 17.4 0 17.7 17.1 07/19/2005 14:30:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 1 0.5 2.3 0.4 303 13 294 255 17.8 0 18 17.4 07/19/2005 14:40:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 292 10 297 255 17.8 0 18 17.7 07/19/2005 14:50:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.3 0.5 2.3 0.4 316 8 326 255 17.8 0 18 17.4 07/19/2005 15:00:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 307 13 315 255 17.9 0 18.2 17.7 07/19/2005 15:10:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 304 10 308 255 17.8 0 18 17.7 07/19/2005 15:20:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.3 0.6 2.6 0.4 307 12 315 255 18 0 18.2 17.7 07/19/2005 15:30:00 2 0.5 3 0.7 1.9 0.6 3.4 0.4 1.4 0.7 3 0.4 312 12 323 255 18 0 18 17.7 07/19/2005 15:40:00 1.9 0.8 3.4 0.4 1.8 0.8 3 0.4 1.4 0.8 3 0.4 308 18 304 255 17.8 0 18 17.7 07/19/2005 15:50:00 1.9 0.5 3.4 0.7 1.8 0.6 3.4 0.4 1.6 0.6 2.6 0.4 299 13 316 255 17.8 0 18 17.4 07/19/2005 16:00:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 306 12 313 255 17.7 0 17.7 17.4 07/19/2005 16:10:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 300 22 296 255 17.9 0 18 17.7 07/19/2005 16:20:00 0.9 0.5 2.6 0.4 0.8 0.5 1.9 0.4 0.7 0.4 2.3 0.4 297 28 318 255 18.2 0 18.2 17.7 07/19/2005 16:30:00 1.7 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.1 0.6 2.6 0.4 309 12 298 255 18.2 0 18.2 18 07/19/2005 16:40:00 1.9 0.5 3 0.4 1.7 0.5 3 0.4 1.4 0.5 3 0.4 310 12 299 255 18.2 0 18.2 18 07/19/2005 16:50:00 1.3 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 302 18 285 255 18.2 0 18.2 18 07/19/2005 17:00:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 327 11 337 255 18.5 0 18.8 18.2 07/19/2005 17:10:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 306 13 306 255 18.7 0 18.8 18.5 07/19/2005 17:20:00 1.4 0.7 3.4 0.4 1.3 0.7 3.4 0.4 0.9 0.7 3 0.4 289 28 314 255 18.7 0 18.8 18.5 07/19/2005 17:30:00 1.8 0.6 3 0.4 1.5 0.7 3 0.4 1.4 0.6 2.6 0.4 320 13 318 255 18.7 0 18.8 18.5 07/19/2005 17:40:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 315 22 306 255 18.7 0 18.8 18.5 07/19/2005 17:50:00 2 0.4 2.6 0.4 1.9 0.4 2.6 0.4 1.4 0.6 2.6 0.4 312 8 317 255 18.5 0.1 18.8 18.2 07/19/2005 18:00:00 1.9 0.3 2.6 0.7 1.7 0.4 2.6 0.7 1.2 0.5 2.6 0.4 312 10 287 255 18.3 0 18.5 18.2 07/19/2005 18:10:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.6 2.3 0.4 299 12 296 255 18.4 0 18.5 18.2 07/19/2005 18:20:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 302 11 312 255 18.4 0 18.5 18.2 07/19/2005 18:30:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 310 10 317 255 18.3 0 18.5 18.2 07/19/2005 18:40:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 316 12 302 255 18.5 0 18.5 18.2 07/19/2005 18:50:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 314 13 310 255 18.4 0 18.5 18.2 07/19/2005 19:00:00 1.2 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 328 22 330 255 18.4 0 18.5 18.2 07/19/2005 19:10:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 316 6 305 255 18.3 0 18.2 18.2 07/19/2005 19:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 328 8 319 255 18.4 0 18.5 18.2 07/19/2005 19:30:00 1.2 0.4 2.3 0.4 0.7 0.3 1.5 0.4 0.6 0.4 1.9 0.4 336 12 343 255 18.4 0 18.5 18 07/19/2005 19:40:00 1.2 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 340 6 346 255 18.1 0 18.2 18 07/19/2005 19:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 322 11 309 255 18 0 18.2 17.7 07/19/2005 20:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 305 15 303 255 18 0 18.2 17.7 07/19/2005 20:10:00 0.8 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 321 1 322 255 17.8 0 18.2 17.7 07/19/2005 20:20:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 311 10 320 255 17.8 0 18 17.7 07/19/2005 20:30:00 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 312 9 319 255 17.7 0 18 17.4 07/19/2005 20:40:00 1.1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 320 4 319 255 17.5 0 18 17.4 07/19/2005 20:50:00 1.2 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.5 0.4 324 13 317 255 17.3 0.1 17.7 17.1 07/19/2005 21:00:00 0.9 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 342 1 341 255 17.1 0 17.7 16.8 07/19/2005 21:10:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 337 15 352 255 17 0 17.4 16.8 07/19/2005 21:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 324 5 322 255 16.8 0 17.1 16.8 07/19/2005 21:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 329 255 16.7 0 16.8 16.6 07/19/2005 21:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 329 255 16.6 0 16.8 16.6 07/19/2005 21:50:00 0.5 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 329 0 329 255 16.5 0 16.8 16.6 07/19/2005 22:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 329 255 16.4 0 16.8 16.3 07/19/2005 22:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 328 255 16.3 0.1 16.8 16.3 07/19/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 0 255 255 16.3 0.1 16.8 16.3 07/19/2005 22:30:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 351 12 357 255 16.1 0 16.8 16.3 07/19/2005 22:40:00 1.1 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 3 5 7 255 16.1 0.1 16.8 16.3 07/19/2005 22:50:00 1 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 345 11 1 255 16.1 0 16.8 16 07/19/2005 23:00:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 337 0 337 255 16.1 0 16.6 16 07/19/2005 23:10:00 0.8 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.7 0.4 347 13 352 255 16.1 0 16.6 16 07/19/2005 23:20:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 359 2 7 255 16 0 16.6 16 07/19/2005 23:30:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 357 2 353 255 16 0 16.6 16 07/19/2005 23:40:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 5 8 6 255 15.9 0 16.3 16 07/19/2005 23:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 24 8 6 255 15.9 0 16.6 16 07/20/2005 00:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 27 92 255 15.8 0 16.3 15.7 07/20/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 0 255 255 15.6 0 16 15.7 07/20/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 0 255 255 15.5 0 15.7 15.5 07/20/2005 00:30:00 0.5 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 77 28 21 255 15.3 0 15.7 15.5 07/20/2005 00:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 24 9 31 255 15.3 0 15.7 15.2 07/20/2005 00:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 0 19 255 15.3 0 15.5 15.2 07/20/2005 01:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 18 2 19 255 15.2 0 15.5 15.2 07/20/2005 01:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 13 0 12 255 15.1 0 15.5 15.2 07/20/2005 01:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 348 9 359 255 15 0 15.5 15.2 07/20/2005 01:30:00 0.7 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0 15 13 255 15 0 15.5 14.9 07/20/2005 01:40:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 6 5 4 255 15 0 15.5 14.9 07/20/2005 01:50:00 0.6 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.1 1.1 0.4 7 3 7 255 14.8 0.2 15.5 14.6 07/20/2005 02:00:00 0.5 0.4 1.9 0.4 0.4 0.3 1.5 0.4 0.4 0 0.7 0.4 23 4 15 255 14.7 0.1 15.2 14.6 07/20/2005 02:10:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 22 4 24 255 14.6 0.1 15.2 14.6 07/20/2005 02:20:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 38 2 23 255 14.6 0 15.2 14.4 07/20/2005 02:30:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 36 1 38 255 14.5 0 14.9 14.4 07/20/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 255 255 14.5 0 14.9 14.4 07/20/2005 02:50:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 35 0 35 255 14.5 0 14.9 14.4 07/20/2005 03:00:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 24 6 9 255 14.4 0 14.9 14.4 07/20/2005 03:10:00 1.2 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.5 0.4 25 10 21 255 14.3 0 14.9 14.4 07/20/2005 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 35 255 14.2 0.1 14.6 14.1 07/20/2005 03:30:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 78 16 35 255 14.1 0.1 14.6 13.8 07/20/2005 03:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 67 27 21 255 14.1 0.1 14.6 13.8 07/20/2005 03:50:00 0.8 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 33 3 36 255 14 0.1 14.6 13.8 07/20/2005 04:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 18 13 29 255 14 0.1 14.6 13.8 07/20/2005 04:10:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 37 2 39 255 14 0.1 14.6 13.8 07/20/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 255 255 14.1 0.2 14.6 13.8 07/20/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 255 255 14.2 0.2 14.6 13.8 07/20/2005 04:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 35 255 14.2 0.1 14.6 13.8 07/20/2005 04:50:00 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 45 12 63 255 14.1 0.1 14.6 13.8 07/20/2005 05:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 35 0 35 255 14.1 0.1 14.6 13.8 07/20/2005 05:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 44 6 35 255 14 0.1 14.6 13.8 07/20/2005 05:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 0 49 255 14 0.1 14.6 13.8 07/20/2005 05:30:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 56 3 49 255 14 0.1 14.6 13.8 07/20/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 0 255 255 14.1 0.1 14.6 13.8 07/20/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 0 255 255 14.2 0.1 14.6 14.1 07/20/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 0 255 255 14.1 0.1 14.6 14.1 07/20/2005 06:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 0 58 255 14 0.1 14.6 13.8 07/20/2005 06:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 59 2 62 255 14.2 0.1 14.9 13.8 07/20/2005 06:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 64 4 62 255 14.5 0 15.2 14.4 07/20/2005 06:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 44 255 14.8 0 15.2 14.6 07/20/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 1 47 255 15 0 15.5 14.9 07/20/2005 07:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 47 255 15.2 0.1 15.7 15.2 07/20/2005 07:10:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 19 15 20 255 15.4 0.2 16 15.2 07/20/2005 07:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 21 8 11 255 15.5 0 16 15.5 07/20/2005 07:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 18 20 35 255 15.5 0 16 15.5 07/20/2005 07:40:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 25 14 17 255 15.5 0 16 15.5 07/20/2005 07:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 19 11 19 255 15.5 0 16 15.5 07/20/2005 08:00:00 1.1 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.9 0.4 6 10 356 255 15.7 0.1 16.3 15.7 07/20/2005 08:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 352 8 326 255 16 0.1 16.8 15.7 07/20/2005 08:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 4 5 12 255 16.4 0.1 16.8 16.3 07/20/2005 08:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 3 15 13 255 17.4 0.4 18.2 16.8 07/20/2005 08:40:00 1.9 0.6 3.4 0.7 1.7 0.7 3 0.4 1.2 0.8 3.4 0.4 6 17 17 255 17.8 0 18.2 17.4 07/20/2005 08:50:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.1 0.7 3.4 0.4 12 6 19 255 17.3 0.1 17.7 17.1 07/20/2005 09:00:00 2.2 0.4 3 0.7 2 0.4 3 0.7 1.4 0.6 2.6 0.4 11 9 7 255 17 0.1 17.4 16.8 07/20/2005 09:10:00 2.3 0.4 3.4 1.5 2.2 0.4 3 1.5 1.8 0.6 3 0.4 15 10 10 255 16.8 0 17.1 16.8 07/20/2005 09:20:00 2.2 0.4 3.4 1.1 2 0.5 3 0.4 1.8 0.5 3.4 0.4 11 17 24 255 17.1 0 17.1 16.8 07/20/2005 09:30:00 1.2 0.5 2.6 0.4 1 0.5 2.6 0.4 0.9 0.5 1.9 0.4 6 16 8 255 17.3 0.1 17.7 17.1 07/20/2005 09:40:00 1.9 0.5 3 0.7 1.6 0.6 2.6 0.4 1.3 0.6 2.6 0.4 2 17 2 255 17.2 0.2 17.7 16.8 07/20/2005 09:50:00 2.2 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.9 0.6 3.4 0.4 13 17 354 255 18.1 0 18.2 17.7 07/20/2005 10:00:00 2.3 0.4 3.4 0.7 2.1 0.5 3.4 0.7 1.8 0.6 3.4 0.4 11 15 354 255 18.7 0.3 19.1 18 07/20/2005 10:10:00 2.3 0.5 3.8 1.1 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 0 15 358 255 19.2 0.3 20.3 18.5 07/20/2005 10:20:00 3.1 0.6 5.7 1.1 2.9 0.6 4.9 1.5 2.4 1 4.9 0.4 359 16 349 255 20.3 0 20.8 19.7 07/20/2005 10:30:00 3 0.6 4.6 1.1 2.7 0.7 4.6 0.7 2.5 0.8 4.2 0.4 334 22 0 255 19.9 0.4 20.8 19.1 07/20/2005 10:40:00 2.2 0.8 3.8 0.4 1.9 0.7 3.8 0.4 1.6 0.8 3.4 0.4 339 24 345 255 19.4 0.1 20 19.1 07/20/2005 10:50:00 2.6 0.5 3.8 0.7 2.4 0.5 3.8 0.7 1.9 0.6 3.8 0.4 336 22 350 255 19.4 0 20 19.1 07/20/2005 11:00:00 2.7 0.7 5.3 0.4 2.6 0.7 4.9 0.4 2.2 0.7 4.2 0.4 326 30 305 255 20.8 0.4 21.4 20 07/20/2005 11:10:00 3.2 1 5.3 0.4 3 1.1 4.9 0.4 2.8 1.2 4.9 0.4 313 20 311 255 21.5 0 21.7 21.1 07/20/2005 11:20:00 2.7 1 5.7 0.7 2.6 1 5.7 0.4 2.4 1 5.3 0.4 309 26 289 255 20.7 0.2 21.7 20.3 07/20/2005 11:30:00 2.4 0.8 4.2 0.4 2.3 0.9 4.2 0.4 1.8 0.9 3.8 0.4 316 53 285 255 20.4 0 21.1 20.3 07/20/2005 11:40:00 3.2 1 5.7 0.7 2.9 1 5.7 0.4 2.3 1.1 5.3 0.4 319 23 312 255 20.2 0.1 20.8 20 07/20/2005 11:50:00 2.7 0.8 4.6 0.4 2.5 0.8 4.2 0.4 2 0.9 4.2 0.4 327 26 349 255 20.3 0.2 20.8 20 07/20/2005 12:00:00 2.5 0.9 5.3 0.4 2.2 0.9 4.9 0.4 1.4 0.9 4.2 0.4 341 24 345 255 21.6 0.6 22.9 20.5 07/20/2005 12:10:00 3 1 4.9 0.4 2.8 1 4.6 0.4 2.6 1.1 4.6 0.4 317 27 309 255 21.9 0.2 22.6 21.7 07/20/2005 12:20:00 2.5 0.9 4.2 0.4 2.4 0.9 4.2 0.4 1.9 1 4.2 0.4 316 32 339 255 22.1 0.2 22.9 21.7 07/20/2005 12:30:00 2.1 1 4.2 0.4 1.9 1 4.2 0.4 1.7 0.9 4.2 0.4 297 32 336 255 21.3 0.2 22 20.8 07/20/2005 12:40:00 2.2 1 4.6 0.4 2 1.1 4.2 0.4 1.8 1 4.6 0.4 320 20 321 255 21.1 0.3 21.7 20.5 07/20/2005 12:50:00 1.2 0.9 3.8 0.4 1.1 0.9 3.8 0.4 0.9 0.8 3.4 0.4 292 30 291 255 20.8 0 21.1 20.5 07/20/2005 13:00:00 1.9 0.8 4.2 0.4 1.8 0.8 4.2 0.4 1.5 0.8 3.8 0.4 283 21 262 255 20.7 0.2 21.1 20.3 07/20/2005 13:10:00 2.5 1 4.9 0.4 2.4 1 4.9 0.4 2.2 0.9 4.9 0.4 322 22 303 255 21.6 0.2 22 21.1 07/20/2005 13:20:00 2.2 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.8 0.9 4.2 0.4 305 39 337 255 22 0.5 22.9 21.4 07/20/2005 13:30:00 2.6 1 4.6 0.4 2.4 0.9 4.6 0.4 2 0.9 4.2 0.4 305 47 346 255 23 0.1 23.5 22.9 07/20/2005 13:40:00 2.3 1 4.6 0.4 2.1 1 4.6 0.4 1.8 1.1 4.9 0.4 305 36 351 255 23.1 0.3 23.8 22.9 07/20/2005 13:50:00 3.5 0.9 5.7 1.9 3.3 0.9 5.7 1.5 2.8 1 5.3 0.7 277 30 294 255 23.5 0 23.8 23.5 07/20/2005 14:00:00 3.8 1 5.7 1.1 3.7 1 5.7 0.7 3.2 1 5.3 0.4 308 20 288 255 23.3 0 23.5 23.2 07/20/2005 14:10:00 2.7 0.7 4.2 0.7 2.6 0.8 4.6 0.4 2.3 0.8 4.2 0.7 287 22 313 255 22.4 0.7 23.5 21.4 07/20/2005 14:20:00 2.3 0.7 4.6 0.4 2.2 0.8 4.6 0.4 1.8 0.8 4.6 0.4 289 29 257 255 21.1 0.2 21.7 20.5 07/20/2005 14:30:00 2.4 0.7 3.8 0.4 2.2 0.8 3.8 0.4 1.6 0.7 3.4 0.4 310 18 278 255 20.5 0 21.1 20.3 07/20/2005 14:40:00 2.1 0.8 4.2 0.4 1.8 0.8 4.2 0.4 1.4 0.8 4.2 0.4 323 15 319 255 19.7 0.2 20.3 19.4 07/20/2005 14:50:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1 0.6 2.6 0.4 1 28 34 255 19 0.2 19.4 18.5 07/20/2005 15:00:00 2.1 0.4 3 0.7 1.9 0.4 3 0.7 1.3 0.5 3.4 0.4 346 39 336 255 18.1 0.2 19.1 17.7 07/20/2005 15:10:00 1.2 0.4 2.3 0.4 1 0.5 2.3 0.4 1.2 0.3 3 0.4 235 19 274 255 17.4 0.2 18.2 17.1 07/20/2005 15:20:00 2.8 1 4.9 1.1 2.9 1.1 5.3 1.1 1.9 0.8 4.2 0.4 230 17 208 255 17.1 0 17.4 16.8 07/20/2005 15:30:00 1.6 1 3.8 0.4 1.5 1 3.4 0.4 1 0.8 3.4 0.4 345 39 13 255 17 0 17.4 16.8 07/20/2005 15:40:00 1 0.8 3 0.4 1 0.8 3 0.4 0.7 0.6 2.6 0.4 0 39 73 255 17.3 0 17.7 17.1 07/20/2005 15:50:00 3.3 0.9 6.1 1.9 3.3 0.9 5.7 1.9 2.6 1 5.7 0.4 100 18 130 255 17.5 0.1 17.7 17.1 07/20/2005 16:00:00 2.4 0.8 4.6 0.4 2.4 0.8 4.6 0.7 1.7 0.8 3.8 0.4 63 26 106 255 17.1 0 17.1 16.8 07/20/2005 16:10:00 2.5 0.5 3.4 0.7 2.5 0.5 3.4 1.1 2 0.5 3 0.7 61 33 29 255 17.4 0.1 17.7 16.8 07/20/2005 16:20:00 2.7 0.7 4.2 0.4 2.7 0.7 3.8 0.4 1.8 0.8 3.8 0.4 104 21 90 255 17.4 0 17.7 17.1 07/20/2005 16:30:00 2.6 1.5 5.7 0.4 2.6 1.5 5.7 0.4 2 1.5 6.1 0.4 101 21 100 255 17.4 0 17.7 17.1 07/20/2005 16:40:00 5.4 1.3 9.1 1.5 5.4 1.2 9.1 1.5 4.3 1.3 7.6 0.7 97 22 106 255 16.9 0.1 17.4 16.6 07/20/2005 16:50:00 6.2 1.7 10.7 2.6 6.2 1.7 11.1 2.6 5.3 1.6 10.3 1.5 101 18 100 255 16.2 0.3 16.8 15.5 07/20/2005 17:00:00 7.5 2 13.3 3.8 7.6 2 13.7 3.8 6.5 2.1 11.8 1.5 112 20 115 255 14.9 0.3 15.7 14.4 07/20/2005 17:10:00 6.6 2.1 13 2.3 6.7 2 12.6 2.3 5.6 1.8 14.1 1.9 108 21 94 255 14.4 0.1 14.9 14.4 07/20/2005 17:20:00 6.5 1.6 11.5 2.3 6.6 1.7 11.5 2.3 5.3 1.6 9.1 0.7 95 20 93 255 14.2 0.2 14.6 13.8 07/20/2005 17:30:00 5.7 1.3 9.9 1.9 5.7 1.3 9.9 1.9 4.8 1.3 8.8 0.7 97 16 96 255 14.4 0.1 15.2 13.8 07/20/2005 17:40:00 6 1.4 9.1 2.6 6.1 1.3 9.1 3 4.9 1.3 8 1.9 96 14 117 255 14.7 0 15.2 14.6 07/20/2005 17:50:00 5.5 1.1 8.4 3 5.7 1.1 8 3 4.7 1.2 7.6 1.5 107 13 104 255 14.8 0 15.2 14.6 07/20/2005 18:00:00 5.7 1.3 8.8 2.6 5.7 1.3 8.8 2.6 4.5 1.3 7.2 1.5 96 21 81 255 15 0 15.7 14.9 07/20/2005 18:10:00 5.3 1.1 8.4 3 5.5 1.1 8.8 3 4.3 1.2 7.6 1.5 88 14 98 255 15.5 0 16 15.5 07/20/2005 18:20:00 4.8 1.1 8.4 2.3 5 1.1 8 2.3 3.7 1.3 8 0.4 84 17 113 255 16.1 0.2 16.8 15.7 07/20/2005 18:30:00 5.6 1 7.6 2.3 5.7 0.9 8 2.6 4.6 1.1 7.2 1.5 87 15 66 255 16.1 0 16.8 16 07/20/2005 18:40:00 5.3 1.1 8.4 2.3 5.3 1.2 8 2.3 4.4 1.1 7.2 1.9 94 15 96 255 16.1 0 16.8 16 07/20/2005 18:50:00 4.5 1 8 1.9 4.5 1.1 7.6 1.5 3.8 1 7.2 1.5 93 15 89 255 16.2 0.1 16.8 16.3 07/20/2005 19:00:00 4.8 1.1 7.6 2.6 4.8 1.1 7.2 2.6 3.9 1.1 6.5 1.5 107 16 107 255 16.2 0 16.8 16 07/20/2005 19:10:00 4.7 1 7.2 2.3 4.7 1 7.2 1.9 3.7 1 6.5 1.1 115 17 136 255 16.1 0 16.6 16 07/20/2005 19:20:00 4.3 0.9 6.8 1.5 4.2 0.9 6.1 1.9 3.4 0.7 5.3 1.9 123 16 93 255 16 0 16.6 16 07/20/2005 19:30:00 3.8 0.9 6.1 1.5 3.7 0.8 6.1 1.9 3.2 0.8 5.7 1.1 124 17 115 255 16 0 16.3 15.7 07/20/2005 19:40:00 3.5 1 6.5 1.1 3.4 1 6.5 1.1 2.8 0.8 5.3 0.7 121 20 84 255 15.8 0 16.3 15.7 07/20/2005 19:50:00 3.2 1.1 6.1 0.4 3.2 1.1 5.7 0.4 2.5 1 4.9 0.4 92 23 101 255 15.7 0 16.3 15.7 07/20/2005 20:00:00 3.6 0.9 5.7 1.5 3.5 0.9 6.1 1.1 2.9 1 5.3 0.7 98 15 106 255 15.5 0 16.3 15.5 07/20/2005 20:10:00 3.5 0.7 5.7 1.9 3.4 0.8 5.3 1.1 2.7 0.8 4.9 0.4 99 15 109 255 15.5 0 16 15.5 07/20/2005 20:20:00 3.1 0.7 4.9 1.5 3.1 0.8 5.3 1.9 2.4 0.8 4.6 0.7 77 14 66 255 15.2 0.1 16 15.2 07/20/2005 20:30:00 3.5 0.7 6.1 1.9 3.5 0.7 6.1 1.9 2.7 0.7 5.3 1.5 82 10 80 255 14.6 0.2 15.5 14.4 07/20/2005 20:40:00 3.6 0.7 5.7 2.3 3.6 0.8 6.1 1.9 2.9 0.8 5.3 1.5 72 11 71 255 14.4 0.1 15.2 14.4 07/20/2005 20:50:00 2.9 0.6 4.6 1.5 2.9 0.6 4.9 1.1 2.3 0.6 4.2 0.7 80 11 72 255 14.5 0.1 15.2 14.1 07/20/2005 21:00:00 3.3 0.7 5.3 1.9 3.2 0.7 5.3 1.9 2.3 0.7 4.2 0.4 83 15 102 255 13.9 0 14.6 13.5 07/20/2005 21:10:00 3.9 0.9 6.1 1.9 3.9 1 6.1 1.5 3.1 1 5.7 1.1 68 17 55 255 13.8 0.2 14.6 13.5 07/20/2005 21:20:00 3.5 0.7 5.7 1.9 3.4 0.7 6.1 1.9 2.5 0.6 4.6 1.1 65 15 63 255 14.2 0 14.6 13.8 07/20/2005 21:30:00 3.4 1 7.2 1.1 3.4 1 7.2 0.7 2.6 1 5.3 0.7 72 15 63 255 13.9 0 14.6 13.8 07/20/2005 21:40:00 4 0.7 6.1 1.9 4 0.8 6.1 2.3 2.9 0.9 5.3 0.4 72 12 67 255 13.7 0 14.1 13.5 07/20/2005 21:50:00 4.4 0.8 6.5 2.3 4.4 0.8 6.5 2.3 3.5 0.9 6.1 1.1 70 11 89 255 13.7 0 14.4 13.5 07/20/2005 22:00:00 4.2 0.8 5.7 1.9 4.2 0.7 5.7 1.9 3.3 0.8 5.7 1.5 67 12 67 255 13.8 0 13.8 13.5 07/20/2005 22:10:00 3.1 0.7 4.9 1.5 3.2 0.7 5.3 1.5 2.2 0.8 4.6 0.7 59 13 66 255 13.7 0 13.8 13.3 07/20/2005 22:20:00 3.2 0.7 5.3 1.9 3.2 0.7 5.3 1.9 2.4 0.6 4.2 1.1 55 11 74 255 13.1 0.2 13.5 12.7 07/20/2005 22:30:00 3.8 0.7 6.5 1.5 3.9 0.8 6.1 1.9 2.9 0.9 5.3 1.1 67 13 62 255 12.7 0 13 12.5 07/20/2005 22:40:00 3.7 0.7 5.3 1.9 3.8 0.7 5.3 2.3 2.7 0.7 4.6 1.1 70 14 53 255 12.5 0 12.7 12.2 07/20/2005 22:50:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 2.3 2.4 0.6 3.8 0.7 82 13 78 255 12 0.1 12.2 11.7 07/20/2005 23:00:00 3.5 0.5 4.9 1.9 3.5 0.5 4.9 1.9 2.3 0.6 3.8 0.7 89 9 91 255 11.6 0 11.7 11.4 07/20/2005 23:10:00 3.4 0.5 4.9 2.3 3.4 0.5 4.9 2.3 2.3 0.6 3.4 0.7 93 9 102 255 11.3 0 11.4 11.1 07/20/2005 23:20:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 2.2 0.5 3.4 1.1 79 9 89 255 11.4 0 11.7 11.4 07/20/2005 23:30:00 2.5 0.5 4.2 1.9 2.6 0.5 4.2 1.9 2 0.5 3.8 0.7 79 6 78 255 11.1 0 11.4 10.9 07/20/2005 23:40:00 2.7 0.5 4.6 1.5 2.7 0.5 4.9 1.5 1.5 0.7 3 0.4 79 9 69 255 10.5 0.1 11.1 10.3 07/20/2005 23:50:00 3.1 0.9 6.5 1.5 3.2 0.8 6.1 1.5 2 0.9 5.7 0.4 77 13 79 255 10.1 0 10.3 9.8 07/21/2005 00:00:00 4.4 0.8 6.5 2.6 4.5 0.8 6.8 2.6 3.3 0.8 5.3 0.7 77 12 86 255 10.2 0.1 10.6 10.1 07/21/2005 00:10:00 4.1 0.6 5.3 2.3 4.1 0.6 5.7 1.9 3.1 0.6 4.6 1.5 85 12 78 255 10.9 0.1 11.1 10.6 07/21/2005 00:20:00 4 0.9 6.1 1.5 4 0.9 6.1 1.5 2.9 0.8 5.7 0.7 80 12 64 255 11.4 0 11.7 11.1 07/21/2005 00:30:00 4.4 0.9 6.5 1.9 4.4 0.9 6.5 1.9 3.4 0.9 5.7 1.5 80 12 77 255 11.9 0.1 12.2 11.7 07/21/2005 00:40:00 4.3 0.8 6.8 2.6 4.4 0.7 6.8 2.3 3.4 0.9 6.8 1.1 71 13 55 255 12.3 0 12.2 12.2 07/21/2005 00:50:00 4.4 1 6.8 2.3 4.5 1 6.8 1.9 3.3 1 6.1 1.5 74 14 66 255 12.3 0 12.5 12.2 07/21/2005 01:00:00 4.5 0.9 7.2 2.3 4.6 0.9 7.2 2.3 3.5 0.8 5.7 1.5 83 13 70 255 12.4 0 12.5 12.2 07/21/2005 01:10:00 4.2 1 6.5 1.9 4.3 1 6.8 2.3 3.1 0.9 5.3 0.7 88 13 70 255 12.3 0 12.5 12.2 07/21/2005 01:20:00 3.8 0.7 6.1 2.3 3.8 0.7 5.7 1.9 2.8 0.7 4.6 0.7 95 12 111 255 12 0.1 12.2 11.7 07/21/2005 01:30:00 4 0.7 6.5 2.6 4.1 0.6 5.7 2.6 3.2 0.6 5.3 1.5 92 9 92 255 11.9 0 11.9 11.7 07/21/2005 01:40:00 4.3 0.6 5.7 3 4.3 0.6 6.1 3 3.3 0.6 4.6 1.5 95 9 95 255 11.7 0 11.7 11.4 07/21/2005 01:50:00 4 0.6 5.7 1.5 4.1 0.6 5.7 2.3 3 0.7 4.6 1.1 103 10 90 255 11.4 0 11.7 11.4 07/21/2005 02:00:00 3.6 0.6 5.3 1.9 3.8 0.6 5.7 2.3 2.8 0.6 4.2 1.1 102 11 101 255 11.2 0 11.4 11.1 07/21/2005 02:10:00 3.8 0.7 4.9 1.1 3.9 0.7 5.3 1.9 2.8 0.8 4.6 0.7 108 11 105 255 10.9 0 11.1 10.9 07/21/2005 02:20:00 3.4 0.9 5.3 0.4 3.6 0.8 5.3 1.1 2.4 0.7 4.6 0.7 114 16 105 255 10.7 0.1 11.1 10.6 07/21/2005 02:30:00 2.8 0.8 4.6 0.7 3.1 0.6 4.6 1.5 2.2 0.6 3.8 0.7 124 13 133 255 10.6 0 10.6 10.6 07/21/2005 02:40:00 4.1 0.9 6.1 1.5 4.3 0.8 6.1 1.9 3.4 0.7 4.9 1.9 126 13 127 255 10.7 0.1 11.1 10.3 07/21/2005 02:50:00 3.9 1 6.5 1.5 4.1 0.9 6.5 1.5 3.2 0.9 6.1 1.1 123 12 122 255 11.1 0 11.1 10.9 07/21/2005 03:00:00 3.9 0.8 6.1 1.5 4.1 0.8 6.5 2.6 2.9 0.9 4.9 0.4 118 15 129 255 11.1 0 11.1 11.1 07/21/2005 03:10:00 3.7 0.6 5.3 1.9 3.8 0.6 5.3 2.3 2.8 0.7 4.2 1.1 104 11 116 255 11 0 11.1 10.9 07/21/2005 03:20:00 3.7 0.4 4.6 2.3 3.8 0.4 4.9 3 2.8 0.5 3.8 0.7 95 7 95 255 10.7 0 10.9 10.6 07/21/2005 03:30:00 4.2 0.5 5.3 2.6 4.3 0.5 5.3 2.6 3.1 0.5 4.6 1.5 95 8 80 255 10.2 0 10.6 10.1 07/21/2005 03:40:00 3.9 0.5 4.9 2.6 4.1 0.4 5.3 3 2.8 0.5 4.2 1.1 98 8 86 255 10.2 0.1 10.6 10.1 07/21/2005 03:50:00 4 0.7 5.3 1.5 4.2 0.6 5.3 2.3 2.9 0.8 4.6 0.7 104 12 94 255 10.4 0.1 10.6 10.3 07/21/2005 04:00:00 3.6 0.6 4.9 1.5 3.9 0.6 4.9 1.9 2.6 0.7 4.2 0.4 106 10 112 255 10.3 0.1 10.6 10.1 07/21/2005 04:10:00 3.9 0.6 5.3 1.9 4.1 0.5 5.3 2.3 3 0.6 4.9 1.1 104 10 101 255 10.3 0.2 10.6 10.1 07/21/2005 04:20:00 3.7 0.6 4.9 1.9 3.7 0.6 5.3 1.9 2.6 0.7 4.2 1.1 100 9 90 255 10.5 0 10.9 10.3 07/21/2005 04:30:00 2.6 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.7 0.4 2.6 0.7 86 9 85 255 10 0.3 10.6 9.6 07/21/2005 04:40:00 3.4 0.6 4.6 1.5 3.6 0.5 4.9 2.6 2.4 0.5 3.8 0.7 81 6 88 255 9.2 0.1 9.6 9 07/21/2005 04:50:00 2.5 0.6 3.8 0.7 2.6 0.6 3.8 1.1 1.5 0.7 3 0.4 75 6 75 255 9 0 9.3 9 07/21/2005 05:00:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.6 0.3 2.3 0.7 55 8 70 255 9.2 0.1 9.6 9 07/21/2005 05:10:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 2.3 0.3 3 1.1 47 6 49 255 10 0.2 10.3 9.6 07/21/2005 05:20:00 2.2 0.3 3 1.5 2.4 0.3 3 1.5 1.5 0.4 2.6 0.4 50 12 37 255 10.1 0 10.3 9.8 07/21/2005 05:30:00 2.6 0.7 4.2 0.7 2.7 0.6 4.2 1.5 1.6 0.7 3.4 0.4 83 11 104 255 10.3 0.2 10.9 10.1 07/21/2005 05:40:00 2.2 0.7 4.2 0.4 2.2 0.6 4.2 0.4 1.3 0.7 3.8 0.4 90 16 97 255 11.4 0.3 11.9 10.9 07/21/2005 05:50:00 2.8 0.7 4.6 1.1 2.8 0.6 4.6 1.1 2.1 0.7 4.2 0.4 94 13 106 255 13.1 0.6 14.1 11.9 07/21/2005 06:00:00 4 1 6.5 1.1 4 0.9 6.5 1.1 3.2 0.9 5.3 0.4 95 16 80 255 15.1 0.5 16 13.8 07/21/2005 06:10:00 3.6 1.2 6.5 1.1 3.7 1.2 6.5 0.7 2.9 1.1 5.7 0.4 95 21 80 255 16.2 0.1 16.8 16 07/21/2005 06:20:00 2.8 1 5.3 0.4 3.1 1 5.3 0.7 2.4 0.8 4.6 0.4 79 21 26 255 17.1 0.3 18 16.6 07/21/2005 06:30:00 3.4 0.8 5.3 1.1 3.4 0.8 5.3 1.1 2.6 0.8 4.9 0.4 82 13 94 255 17.6 0 18 17.4 07/21/2005 06:40:00 2.5 0.9 5.3 0.4 2.7 0.8 5.3 0.7 2.3 0.7 4.2 0.7 74 20 97 255 18 0.1 18.2 17.7 07/21/2005 06:50:00 1.9 1 4.6 0.4 2.2 0.9 4.9 0.4 1.9 0.8 4.2 0.4 65 22 94 255 18.5 0 18.5 18.2 07/21/2005 07:00:00 3.6 1 6.1 1.5 3.6 1 6.8 0.7 3 1 5.3 0.7 80 18 76 255 18.1 0.2 18.5 17.7 07/21/2005 07:10:00 3.8 1.2 6.8 1.5 3.9 1.1 6.5 1.5 3.5 1.2 6.8 0.4 76 17 97 255 18.7 0.2 19.1 18.2 07/21/2005 07:20:00 3.4 0.9 5.7 0.7 3.3 0.9 5.7 0.7 3 1 5.7 0.7 85 18 64 255 19.1 0.1 20 18.8 07/21/2005 07:30:00 4.5 1.7 8.4 0.4 4.6 1.6 8.4 0.4 4 1.4 7.6 0.7 84 18 70 255 19.2 0.2 20 18.8 07/21/2005 07:40:00 4.2 1.1 7.2 1.9 4.2 1.2 7.2 1.5 3.6 1.3 7.6 0.7 82 20 95 255 19 0 19.4 18.8 07/21/2005 07:50:00 4.4 1.2 7.6 0.4 4.5 1.1 7.6 1.1 3.9 1.1 6.5 1.5 75 15 92 255 18.8 0 19.4 18.5 07/21/2005 08:00:00 4.2 1.1 7.2 1.9 4.2 1.1 6.8 1.5 3.9 1.1 7.2 0.7 75 15 91 255 19 0 19.4 18.8 07/21/2005 08:10:00 4.4 1 6.8 1.5 4.5 1 6.8 1.9 3.8 1 6.1 1.5 69 15 73 255 19.2 0 19.7 19.1 07/21/2005 08:20:00 4.1 1 6.1 1.5 4.1 1 6.5 1.5 3.7 1 6.8 1.9 79 18 78 255 19.2 0 19.7 19.1 07/21/2005 08:30:00 4.1 1.2 8 1.1 4.1 1.1 7.6 1.9 3.4 1.2 7.2 1.1 86 22 95 255 19.5 0.1 20 19.1 07/21/2005 08:40:00 4.3 1.2 8 1.5 4.4 1.1 7.2 1.5 3.9 1.1 7.6 1.1 80 22 84 255 19.5 0.1 20 19.4 07/21/2005 08:50:00 4.4 1.5 7.2 0.4 4.6 1.4 7.6 0.7 4.1 1.3 7.2 0.4 76 22 76 255 19.9 0 20.3 19.4 07/21/2005 09:00:00 2.9 0.8 4.9 1.1 2.9 0.8 4.9 0.7 2.7 0.7 4.2 1.1 50 24 56 255 20.5 0.2 21.1 20 07/21/2005 09:10:00 3.3 1 6.1 0.4 3.3 1 6.1 0.4 3 1 6.1 0.4 57 27 95 255 21 0.1 21.7 20.8 07/21/2005 09:20:00 3.9 1 6.1 1.9 3.9 1 6.5 1.5 3.4 1 6.1 1.1 64 23 93 255 21.1 0.2 21.7 20.8 07/21/2005 09:30:00 5 1.4 8 1.5 5.1 1.4 8 2.3 4.3 1.3 7.6 1.5 61 26 77 255 20.9 0 21.4 20.8 07/21/2005 09:40:00 5.5 1.2 8.8 1.9 5.5 1.2 8.4 2.3 4.9 1.4 8.8 1.9 74 19 75 255 20.8 0.1 21.4 20.5 07/21/2005 09:50:00 5.1 1.2 7.6 1.1 5.2 1.1 8 2.3 4.4 1.2 7.6 1.5 70 18 81 255 20.9 0 21.4 20.5 07/21/2005 10:00:00 4.7 1.3 8.8 1.5 4.8 1.3 8.4 1.5 4.2 1.3 8.4 0.7 79 20 87 255 21.2 0 21.7 21.1 07/21/2005 10:10:00 4.6 1.5 8 0.4 4.6 1.5 8.4 1.1 4 1.4 7.2 1.1 66 26 67 255 21.6 0.1 22 21.1 07/21/2005 10:20:00 6 1.2 10.3 3 6 1.2 10.3 3.4 5.1 1.3 9.1 1.9 61 22 89 255 21.6 0 22.3 21.4 07/21/2005 10:30:00 4.3 1.2 9.1 0.7 4.3 1.2 9.1 1.9 3.7 1.2 7.2 1.1 53 27 122 255 21.7 0.1 22.3 21.4 07/21/2005 10:40:00 3.2 1.2 5.7 0.4 3.2 1.2 6.1 0.4 2.8 1.1 5.3 0.4 55 27 48 255 22.1 0 22.3 22 07/21/2005 10:50:00 4.1 1.4 7.2 0.7 4.1 1.3 6.8 1.1 3.5 1.2 6.5 0.7 51 21 26 255 22.7 0 22.9 22.3 07/21/2005 11:00:00 4.5 1.4 8.8 0.7 4.6 1.3 9.1 1.5 3.9 1.3 8.4 1.5 64 17 62 255 22.4 0.1 22.9 22.3 07/21/2005 11:10:00 4.9 1.5 8.8 1.5 5 1.5 9.5 2.3 4.4 1.5 8.8 1.1 58 23 76 255 22.5 0 22.9 22.3 07/21/2005 11:20:00 4 1.2 6.8 0.7 4.1 1.2 7.2 0.4 3.6 1.3 8 0.4 51 22 49 255 22.8 0 23.2 22.6 07/21/2005 11:30:00 3.4 1.1 7.2 0.4 3.5 1.1 6.1 0.4 3 1.1 6.5 0.4 40 29 45 255 22.8 0.1 23.5 22.9 07/21/2005 11:40:00 2.4 1.1 5.7 0.4 2.4 1.2 5.7 0.4 2.1 0.9 4.9 0.4 21 45 10 255 23.3 0.2 23.8 22.9 07/21/2005 11:50:00 1.5 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.5 0.6 2.6 0.4 28 56 3 255 23.8 0 24.4 23.5 07/21/2005 12:00:00 2.6 0.9 5.3 0.4 2.6 0.9 5.7 1.5 2.4 1 6.1 0.7 3 28 15 255 23.6 0.1 23.8 23.5 07/21/2005 12:10:00 1.8 1 4.6 0.4 1.9 1 4.6 0.4 1.8 0.8 4.6 0.4 13 27 52 255 23.7 0 24.1 23.5 07/21/2005 12:20:00 3.2 1 5.7 0.7 3.3 1.1 6.1 0.4 2.7 1.1 5.3 0.4 42 24 22 255 23.8 0 24.1 23.5 07/21/2005 12:30:00 1.9 1.2 4.6 0.4 1.8 1 4.2 0.4 2 1 4.9 0.4 7 58 330 255 24.3 0 24.7 23.8 07/21/2005 12:40:00 2.3 0.8 4.2 0.4 2.4 0.8 4.6 0.7 2.2 0.7 3.8 0.4 44 30 116 255 24.3 0 24.7 24.1 07/21/2005 12:50:00 2.4 1.1 4.6 0.4 2.5 1 4.6 0.4 2.2 1 4.2 0.4 47 45 78 255 24.4 0 25 24.4 07/21/2005 13:00:00 1.8 0.9 3.8 0.4 1.9 0.8 3.8 0.4 1.7 0.8 3.8 0.4 70 35 85 255 25 0 25.3 25 07/21/2005 13:10:00 3 1.2 5.7 0.4 3.1 1.2 5.3 0.4 2.8 1.3 6.5 0.4 106 30 90 255 24.9 0 25.3 24.7 07/21/2005 13:20:00 3.3 1.1 6.1 0.7 3.4 1 6.1 1.1 2.9 1.1 6.1 0.7 88 30 107 255 24.7 0 25 24.4 07/21/2005 13:30:00 2.3 1 4.2 0.4 2.5 0.9 4.2 0.4 2.4 1 4.2 0.4 92 20 100 255 24.4 0 24.7 24.4 07/21/2005 13:40:00 0.7 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.2 0.5 2.6 0.4 102 32 113 255 25 0.1 25.6 24.7 07/21/2005 13:50:00 1.6 1 3.4 0.4 1.8 0.9 3.8 0.4 1.8 0.8 3.4 0.4 56 38 48 255 25.2 0 25.3 25 07/21/2005 14:00:00 2.2 1 5.3 0.4 2.3 0.9 4.6 0.4 2.1 0.9 4.6 0.4 125 53 160 255 25.1 0 25.3 25 07/21/2005 14:10:00 2.6 1.2 6.5 0.4 2.9 1.2 6.8 0.7 2.7 1.1 5.7 0.7 95 28 96 255 25 0 25.3 25 07/21/2005 14:20:00 1.4 0.9 3.8 0.4 1.7 0.8 4.2 0.4 1.9 0.6 3.8 0.4 63 22 57 255 25.5 0.1 25.6 25 07/21/2005 14:30:00 2.7 1.1 5.3 0.4 2.9 1.1 5.3 0.4 2.4 1 4.6 0.4 69 47 100 255 25.6 0 25.9 25.6 07/21/2005 14:40:00 2.4 1.1 5.3 0.4 2.7 1 5.7 0.7 2.6 1.1 5.7 0.4 112 24 93 255 25.5 0 25.6 25.3 07/21/2005 14:50:00 1.8 1 4.6 0.4 2.3 1 4.6 0.4 2.3 0.8 4.6 0.4 131 30 154 255 25.1 0 25.6 25 07/21/2005 15:00:00 3.3 0.9 5.3 1.1 3.7 0.9 5.7 1.1 3.2 0.9 5.7 0.7 247 41 217 255 25.4 0 25.6 25.3 07/21/2005 15:10:00 3.8 1 6.5 0.4 3.9 1 6.1 1.1 3 1.2 5.7 0.4 339 19 304 255 25.9 0.2 26.2 25.6 07/21/2005 15:20:00 1.9 1 5.3 0.4 2.3 1 5.3 0.4 2 0.9 4.9 0.4 338 27 313 255 26 0 26.5 25.9 07/21/2005 15:30:00 1.5 1.1 4.6 0.4 1.7 1 4.6 0.4 1.5 0.9 4.2 0.4 345 30 326 255 26.3 0 26.5 26.2 07/21/2005 15:40:00 2.2 1 4.6 0.4 2.4 0.8 4.2 0.7 2.3 0.8 4.2 0.4 307 18 331 255 26.1 0 26.5 25.9 07/21/2005 15:50:00 0.9 0.7 3.4 0.4 1.3 0.7 4.2 0.4 1.1 0.6 2.6 0.4 359 43 339 255 26.2 0 26.5 25.9 07/21/2005 16:00:00 3.5 1.1 5.3 0.4 3.7 1.1 5.7 0.7 2.5 1 5.3 0.7 359 18 352 255 26.3 0 26.5 26.2 07/21/2005 16:10:00 4 1 6.1 0.4 4.3 0.9 6.1 1.5 3.5 1 5.3 1.1 21 17 27 255 25.7 0 26.2 25.3 07/21/2005 16:20:00 4.3 0.8 6.5 2.3 4.5 0.8 6.5 2.6 3.6 0.9 6.1 1.9 13 15 354 255 25 0.1 25.6 24.7 07/21/2005 16:30:00 4.8 0.7 6.5 2.6 5 0.7 6.5 2.6 4.2 1 6.5 1.5 28 12 23 255 24.3 0 25 24.1 07/21/2005 16:40:00 4.8 0.9 6.5 1.9 5 0.9 6.8 2.6 4.1 1 6.5 1.5 26 17 39 255 23.8 0 24.1 23.5 07/21/2005 16:50:00 4.8 0.9 6.8 1.9 5 0.8 6.8 2.3 4.2 1.1 6.8 1.5 18 12 25 255 23.6 0 23.8 23.5 07/21/2005 17:00:00 4.5 1.4 6.8 0.4 4.8 1.3 6.8 1.1 3.7 1.3 6.1 0.7 18 16 12 255 23.7 0 23.8 23.5 07/21/2005 17:10:00 5.1 0.9 7.2 2.3 5.4 0.8 7.2 2.3 4.7 1.1 7.2 1.5 19 13 28 255 23.3 0.1 23.5 22.9 07/21/2005 17:20:00 4.7 1.1 6.8 1.1 4.9 1 6.8 1.1 3.6 1.3 6.8 0.7 12 14 20 255 22.7 0 22.9 22.3 07/21/2005 17:30:00 4.8 1.4 7.2 0.4 5 1.3 7.6 1.1 3.6 1.4 6.8 0.4 10 12 12 255 22 0 22.3 21.7 07/21/2005 17:40:00 5.1 1.1 7.2 1.5 5.3 1 7.6 2.3 3.9 1.2 6.8 1.1 16 13 18 255 21.6 0 21.7 21.4 07/21/2005 17:50:00 4.9 1.1 8 1.5 5.1 1 8 1.9 3.9 1.2 7.2 1.1 15 15 24 255 21.6 0 22 21.4 07/21/2005 18:00:00 4.1 1.1 6.5 0.7 4.4 1 6.5 1.5 3 1.1 5.7 0.4 0 17 353 255 21.2 0 21.7 20.8 07/21/2005 18:10:00 3.8 1.2 6.5 0.7 4.1 1 6.5 1.5 3 1 5.3 1.1 9 17 17 255 20.9 0 21.1 20.8 07/21/2005 18:20:00 2.7 1.2 5.3 0.4 2.9 1 5.7 0.7 2.4 1.1 4.9 0.4 340 22 356 255 20.8 0 21.1 20.5 07/21/2005 18:30:00 1.3 0.8 2.6 0.4 1.9 0.8 3.4 0.4 1.3 0.7 3 0.4 335 30 349 255 20.5 0 21.1 20.5 07/21/2005 18:40:00 2.2 1.1 4.2 0.4 2.8 1.1 4.6 0.4 2.4 1.1 4.9 0.4 298 32 293 255 20.5 0 20.8 20.5 07/21/2005 18:50:00 2.2 1.1 4.9 0.4 2.8 1.1 5.3 0.4 2.2 1 4.6 0.4 311 17 307 255 20.5 0 20.8 20.5 07/21/2005 19:00:00 1.8 1 5.3 0.4 2.5 0.9 5.3 0.4 2 1 5.3 0.4 288 27 222 255 20.1 0 20.5 20 07/21/2005 19:10:00 2.1 1 4.9 0.4 2.8 0.9 5.3 1.1 2.2 0.8 3.8 0.4 260 21 268 255 20 0 20.3 19.7 07/21/2005 19:20:00 1.9 1 5.3 0.4 2.5 0.9 4.9 0.4 2.2 0.9 4.9 0.4 279 22 261 255 19.8 0 20.3 19.4 07/21/2005 19:30:00 1.8 0.9 4.6 0.4 2.4 0.8 4.6 0.7 2.1 0.7 4.6 0.4 279 17 287 255 19.7 0.1 20.3 19.4 07/21/2005 19:40:00 1.6 1 4.9 0.4 2.2 0.9 4.9 0.4 2 0.8 4.6 0.4 278 22 261 255 19.7 0 20.3 19.7 07/21/2005 19:50:00 1.1 0.8 3.4 0.4 1.6 0.9 3.8 0.4 1.5 0.8 3.4 0.4 305 24 255 255 19.5 0.1 20.3 19.4 07/21/2005 20:00:00 1 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.3 0.8 3.4 0.4 308 23 319 255 19.2 0.1 19.7 19.1 07/21/2005 20:10:00 1.2 0.6 2.6 0.4 1.7 0.6 3.4 0.4 1.3 0.6 3 0.4 341 15 317 255 18.7 0.1 19.4 18.5 07/21/2005 20:20:00 0.6 0.7 5.3 0.4 1 0.8 4.6 0.4 0.8 0.6 3 0.4 56 90 306 255 18.4 0.1 18.8 18.2 07/21/2005 20:30:00 2.2 1.2 6.1 0.4 2.8 1.2 6.1 0.4 1.9 1 5.7 0.4 246 33 241 255 18.4 0 18.8 18.2 07/21/2005 20:40:00 2.4 1.3 5.7 0.4 2.9 1.2 5.7 0.4 2 1.1 5.3 0.4 251 24 231 255 17.6 0.3 18.2 16.8 07/21/2005 20:50:00 2.3 1.1 4.6 0.4 2.8 1 4.9 0.4 1.9 0.9 4.6 0.4 252 17 238 255 16.5 0.2 17.1 16.3 07/21/2005 21:00:00 1.8 0.9 4.2 0.4 2.5 0.8 4.9 0.7 1.2 0.6 3.4 0.4 266 22 260 255 16 0 16.3 16 07/21/2005 21:10:00 2.5 1.1 4.9 0.4 3 1 5.7 0.4 2 0.8 4.2 0.4 266 19 262 255 15.8 0 16.3 15.7 07/21/2005 21:20:00 2.3 0.8 4.9 0.4 2.9 0.7 6.1 1.1 1.6 0.7 4.2 0.4 257 13 272 255 15.7 0 16.3 15.7 07/21/2005 21:30:00 2.3 0.6 4.6 0.4 2.8 0.6 4.6 1.5 1.7 0.6 3.4 0.4 245 13 251 255 15.6 0 16.3 15.5 07/21/2005 21:40:00 1.9 0.6 3.4 0.4 2.4 0.5 3.8 1.5 1.2 0.4 3 0.4 245 11 234 255 15.4 0 16 15.2 07/21/2005 21:50:00 0.7 0.5 1.9 0.4 1 0.7 2.6 0.4 0.5 0.2 1.5 0.4 259 3 257 255 15.2 0 15.7 15.2 07/21/2005 22:00:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 271 14 255 255 15.1 0 15.5 15.2 07/21/2005 22:10:00 1 0.7 2.6 0.4 1.1 0.8 3 0.4 1.3 0.9 3 0.4 210 66 149 255 15 0 15.5 14.9 07/21/2005 22:20:00 1.2 0.4 2.3 0.4 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 150 8 150 255 15 0 15.5 14.9 07/21/2005 22:30:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.3 1.9 0.4 128 5 119 255 15 0 15.5 14.9 07/21/2005 22:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 126 2 127 255 15 0 15.7 14.9 07/21/2005 22:50:00 1.6 0.4 2.6 0.7 1.8 0.4 2.6 1.1 1.3 0.4 2.3 0.4 110 16 113 255 15 0 15.7 15.2 07/21/2005 23:00:00 1.9 0.8 3.4 0.4 2 0.7 3.8 0.4 1.4 0.8 3.4 0.4 93 9 104 255 15.2 0.2 15.7 15.2 07/21/2005 23:10:00 1.8 0.6 3 0.4 1.9 0.6 3.4 0.7 1.3 0.6 2.6 0.4 94 9 91 255 15.2 0.2 15.7 15.2 07/21/2005 23:20:00 1.5 0.6 3 0.4 1.6 0.5 2.6 0.4 1 0.5 2.3 0.4 107 11 101 255 15.2 0.2 15.7 15.2 07/21/2005 23:30:00 1.3 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1 0.6 2.6 0.4 114 8 100 255 15.1 0.2 15.7 14.9 07/21/2005 23:40:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 126 9 109 255 15 0 15.5 14.9 07/21/2005 23:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 58 13 255 255 14.8 0 15.5 14.6 07/22/2005 00:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 68 33 134 255 14.6 0 15.2 14.6 07/22/2005 00:10:00 1.8 0.5 3 0.4 2 0.5 3 0.7 1.6 0.6 2.6 0.4 133 3 127 255 14.6 0.1 15.2 14.6 07/22/2005 00:20:00 1.6 0.8 3 0.4 1.8 0.7 3 0.4 1.2 0.6 2.6 0.4 127 3 131 255 14.6 0 14.9 14.6 07/22/2005 00:30:00 0.7 0.7 2.6 0.4 0.8 0.7 2.6 0.4 0.6 0.4 2.3 0.4 85 53 26 255 14.5 0 14.9 14.6 07/22/2005 00:40:00 1 0.6 2.6 0.4 1.2 0.7 3 0.4 0.5 0.4 2.3 0.4 15 4 24 255 14.4 0 14.9 14.1 07/22/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 14.2 0 14.4 13.8 07/22/2005 01:00:00 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 46 12 34 255 14.2 0.1 14.6 14.1 07/22/2005 01:10:00 0.8 0.4 1.5 0.4 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 51 2 43 255 14.2 0.2 14.6 13.8 07/22/2005 01:20:00 0.7 0.5 1.9 0.4 0.8 0.6 2.3 0.4 0.6 0.4 1.9 0.4 41 6 51 255 13.9 0 14.6 13.8 07/22/2005 01:30:00 1.6 0.4 2.3 0.4 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 34 11 25 255 13.6 0.1 14.4 13.3 07/22/2005 01:40:00 1.7 0.5 2.6 0.4 1.9 0.4 2.6 0.4 1.5 0.4 2.6 0.7 50 7 46 255 13.2 0 13.5 13 07/22/2005 01:50:00 1.2 0.5 2.3 0.4 1.4 0.4 2.6 0.4 1.1 0.5 2.3 0.4 59 15 56 255 12.9 0 13 12.7 07/22/2005 02:00:00 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.7 0.4 1.9 0.4 77 13 80 255 12.5 0 12.7 12.2 07/22/2005 02:10:00 1.5 0.6 3 0.4 1.6 0.5 3 0.4 0.9 0.4 2.3 0.4 78 8 68 255 12 0.2 12.2 11.7 07/22/2005 02:20:00 2 0.5 3 0.4 2.1 0.5 3.4 0.7 1.3 0.5 2.6 0.4 65 11 61 255 11.5 0 11.7 11.4 07/22/2005 02:30:00 1.6 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.3 0.7 3 0.4 62 9 70 255 11.2 0 11.9 10.9 07/22/2005 02:40:00 2.4 0.6 4.2 1.1 2.6 0.5 4.2 1.5 1.7 0.5 3 0.4 77 9 62 255 10.8 0.1 11.1 10.6 07/22/2005 02:50:00 2.4 0.6 4.2 1.1 2.6 0.6 4.6 1.1 1.6 0.6 4.2 0.4 70 11 74 255 10.6 0 10.6 10.6 07/22/2005 03:00:00 1.8 0.5 3 0.4 2 0.4 3 0.7 1.4 0.5 2.6 0.4 66 10 56 255 10.5 0 10.6 10.3 07/22/2005 03:10:00 2.3 0.6 4.2 0.7 2.4 0.6 4.2 0.7 1.6 0.5 3 0.4 71 10 61 255 10.3 0 10.6 10.3 07/22/2005 03:20:00 2.6 0.5 3.4 1.5 2.7 0.4 3.8 1.5 1.6 0.4 2.6 0.4 79 7 74 255 10.3 0 10.6 10.3 07/22/2005 03:30:00 2.6 0.6 3.8 1.5 2.8 0.6 4.2 1.5 1.6 0.5 2.6 0.7 84 8 80 255 10.1 0 10.3 9.8 07/22/2005 03:40:00 2.5 0.5 4.2 1.5 2.6 0.5 3.8 1.5 1.7 0.5 3.4 0.7 80 9 81 255 9.8 0 10.1 9.6 07/22/2005 03:50:00 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.4 0.4 2.3 0.4 87 11 77 255 9.7 0 9.8 9.6 07/22/2005 04:00:00 2.4 0.3 3 1.5 2.5 0.3 3 1.9 1.6 0.4 2.6 0.4 99 8 96 255 9.6 0 9.8 9.6 07/22/2005 04:10:00 2.5 0.4 3.4 1.5 2.6 0.3 3.4 1.5 1.8 0.4 3 0.7 103 7 90 255 9.6 0 9.8 9.6 07/22/2005 04:20:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.7 0.5 2.6 0.4 105 8 103 255 9.8 0 9.8 9.8 07/22/2005 04:30:00 1.7 0.4 2.6 0.4 1.8 0.4 3 0.7 1.1 0.4 2.3 0.4 111 7 116 255 9.9 0 10.1 9.8 07/22/2005 04:40:00 2.1 0.5 3 0.7 2 0.5 3 0.7 1.3 0.4 2.3 0.4 111 9 113 255 10.1 0 10.3 10.1 07/22/2005 04:50:00 2 0.6 3.4 0.4 2 0.6 3.4 0.4 1.2 0.5 2.6 0.4 114 14 125 255 10.5 0 10.6 10.1 07/22/2005 05:00:00 2.1 0.6 3.8 0.4 2.1 0.6 3.8 0.4 1.3 0.6 3 0.4 116 12 89 255 10.7 0 11.1 10.6 07/22/2005 05:10:00 2 0.7 4.2 0.4 2 0.7 4.2 0.4 1.2 0.6 2.6 0.4 111 16 106 255 11.2 0 11.4 11.1 07/22/2005 05:20:00 2.3 0.7 3.8 0.4 2.3 0.6 3.8 0.7 1.6 0.7 3.4 0.4 106 15 101 255 11.4 0 11.7 11.4 07/22/2005 05:30:00 2.6 0.6 3.8 1.1 2.6 0.6 3.8 1.1 1.9 0.6 3.4 0.4 100 9 111 255 11.9 0.1 12.5 11.7 07/22/2005 05:40:00 1.8 0.5 3 0.4 1.8 0.6 3.4 0.4 1.3 0.6 3 0.4 97 11 101 255 12.1 0 12.5 11.9 07/22/2005 05:50:00 1.6 0.5 3 0.4 1.5 0.5 3 0.4 1 0.4 1.9 0.4 81 12 96 255 12.3 0 12.7 12.2 07/22/2005 06:00:00 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.4 1.9 0.4 101 8 101 255 13.3 0.4 13.8 12.5 07/22/2005 06:10:00 1.4 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 93 13 96 255 14.5 0.3 15.2 13.8 07/22/2005 06:20:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 97 12 92 255 15.1 0 15.5 15.2 07/22/2005 06:30:00 1.8 0.6 3 0.4 1.8 0.5 2.6 0.4 1.3 0.6 3 0.4 103 15 103 255 15.2 0.2 15.7 15.2 07/22/2005 06:40:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 97 16 92 255 15.4 0 16 15.2 07/22/2005 06:50:00 1 0.5 2.3 0.4 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 88 14 80 255 15.7 0 16.3 15.7 07/22/2005 07:00:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 87 14 108 255 16.4 0.2 17.1 16 07/22/2005 07:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 81 20 95 255 16.7 0 16.8 16.6 07/22/2005 07:20:00 0.6 0.4 2.3 0.4 0.6 0.3 1.9 0.4 0.7 0.4 1.9 0.4 89 29 62 255 17 0 17.1 16.8 07/22/2005 07:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 75 21 73 255 17.1 0 17.1 16.8 07/22/2005 07:40:00 1.1 0.5 2.3 0.4 1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 77 17 99 255 17.3 0.2 17.7 16.8 07/22/2005 07:50:00 1.4 0.4 2.6 0.4 1.3 0.4 2.6 0.4 1.4 0.4 2.6 0.4 28 22 19 255 17.7 0.1 18.2 17.4 07/22/2005 08:00:00 1.3 0.6 2.6 0.4 1.3 0.6 2.3 0.4 1.5 0.5 2.3 0.4 34 10 35 255 18 0 18.5 17.7 07/22/2005 08:10:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.4 2.3 0.4 7 15 356 255 18.5 0.3 19.1 18 07/22/2005 08:20:00 1.7 0.6 3 0.4 1.8 0.7 3.4 0.4 1.5 0.6 3.4 0.4 357 13 0 255 18.5 0.2 19.1 18.2 07/22/2005 08:30:00 1.5 0.7 3 0.4 1.7 0.7 3.4 0.4 1.6 0.6 3 0.4 9 15 6 255 18.7 0 19.4 18.2 07/22/2005 08:40:00 1.1 0.4 2.6 0.4 1.5 0.5 3 0.4 1.7 0.5 3 0.4 20 12 29 255 18.9 0 19.4 18.5 07/22/2005 08:50:00 0.8 0.5 1.9 0.4 1.1 0.6 2.6 0.4 1 0.5 2.3 0.4 21 17 20 255 19.1 0 19.4 18.8 07/22/2005 09:00:00 1.1 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 21 24 15 255 19.4 0 19.7 19.1 07/22/2005 09:10:00 0.7 0.4 1.9 0.4 1.1 0.6 2.3 0.4 1 0.5 1.9 0.4 14 29 340 255 19.6 0.1 20 19.1 07/22/2005 09:20:00 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 359 20 22 255 19.5 0 20 19.4 07/22/2005 09:30:00 0.9 0.4 1.9 0.4 1.3 0.5 2.6 0.4 1.2 0.6 2.3 0.4 343 26 354 255 19.3 0 19.7 19.1 07/22/2005 09:40:00 0.6 0.3 1.9 0.4 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 354 23 11 255 19.7 0 20.3 19.4 07/22/2005 09:50:00 0.4 0.1 1.1 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 6 28 10 255 20.1 0 20.5 20 07/22/2005 10:00:00 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 0.7 0.5 2.3 0.4 30 66 78 255 20.7 0.1 21.1 20.5 07/22/2005 10:10:00 1 0.5 2.3 0.4 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 10 29 347 255 20.8 0.1 21.4 20.5 07/22/2005 10:20:00 1.4 0.6 2.6 0.4 1.9 0.5 3.4 0.4 1.7 0.6 3.4 0.4 337 27 343 255 21.3 0 21.7 21.1 07/22/2005 10:30:00 0.9 0.6 2.6 0.4 1.4 0.6 3 0.4 1.5 0.6 2.6 0.4 311 19 329 255 20.8 0.2 21.1 20.5 07/22/2005 10:40:00 0.4 0.1 1.1 0.4 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 219 69 259 255 20.8 0.1 21.1 20.5 07/22/2005 10:50:00 0.7 0.4 1.9 0.4 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 72 98 357 255 21.3 0 21.7 20.8 07/22/2005 11:00:00 0.9 0.7 3 0.4 1.4 0.7 3.4 0.4 1.2 0.7 3.4 0.4 256 45 326 255 21.4 0.1 21.7 21.1 07/22/2005 11:10:00 1.3 0.7 3.4 0.4 1.9 0.6 3.8 0.4 1.7 0.6 3.8 0.4 335 39 326 255 21.6 0 22.3 21.4 07/22/2005 11:20:00 1 0.7 3 0.4 1.6 0.7 3.4 0.4 1.3 0.7 3.8 0.4 348 28 9 255 22.4 0.3 22.9 21.7 07/22/2005 11:30:00 1.3 0.7 3 0.4 1.7 0.7 3.4 0.4 1.4 0.7 3 0.4 280 69 345 255 22.7 0.2 23.2 22.3 07/22/2005 11:40:00 0.7 0.5 2.3 0.4 1.2 0.8 3 0.4 1.3 0.8 3 0.4 157 49 184 255 22.4 0.1 22.9 21.7 07/22/2005 11:50:00 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.9 0.4 267 86 152 255 22 0 22.3 21.7 07/22/2005 12:00:00 1 0.6 2.6 0.4 1.5 0.8 3.4 0.4 1.4 0.7 3 0.4 197 49 241 255 22.4 0 22.6 22.3 07/22/2005 12:10:00 1.5 1.2 4.9 0.4 2 1.1 5.3 0.4 1.5 1 4.6 0.4 288 49 299 255 22.7 0 22.9 22.6 07/22/2005 12:20:00 1.7 0.8 3.8 0.4 2.3 0.6 3.8 0.7 2.4 0.7 4.2 0.7 300 30 329 255 23 0 23.2 22.9 07/22/2005 12:30:00 1.5 1.2 4.6 0.4 2.1 1 4.9 0.4 1.7 1 4.6 0.4 274 58 300 255 23.4 0.1 23.5 23.2 07/22/2005 12:40:00 2.6 1 4.9 0.4 3 1 5.3 0.4 2.6 1.1 5.7 0.4 302 26 299 255 23.6 0.1 23.8 23.5 07/22/2005 12:50:00 1.4 0.9 4.2 0.4 2 0.8 3.8 0.4 1.6 0.8 3.8 0.4 294 38 270 255 23.7 0.2 24.1 23.5 07/22/2005 13:00:00 1.9 1.1 4.2 0.4 2.3 0.9 4.2 0.4 1.9 1 4.2 0.4 326 27 356 255 24.3 0 24.4 23.8 07/22/2005 13:10:00 2.8 1.1 5.7 0.4 3.2 0.9 5.7 1.1 2.7 1 5.3 0.4 272 22 301 255 24 0.1 24.7 23.8 07/22/2005 13:20:00 1.8 1.1 5.7 0.4 2.3 1 6.1 0.4 1.8 1 4.6 0.4 322 43 290 255 24.1 0.4 25 23.5 07/22/2005 13:30:00 2 1 4.2 0.4 2.6 0.8 4.6 0.4 2.2 1 4.9 0.4 281 28 287 255 24.8 0.1 25.3 24.4 07/22/2005 13:40:00 1.5 0.9 4.2 0.4 2.1 0.8 4.2 0.4 1.9 0.8 3.8 0.4 304 38 262 255 24.5 0 25 24.4 07/22/2005 13:50:00 2.2 1.1 4.6 0.4 2.7 1 4.9 0.7 2.4 0.9 4.9 0.4 281 29 300 255 24.4 0 25 24.4 07/22/2005 14:00:00 2.3 1.2 4.9 0.4 2.7 1.2 4.9 0.4 2.4 1.1 4.9 0.4 281 26 297 255 24.4 0 24.7 24.1 07/22/2005 14:10:00 1.5 0.8 3.4 0.4 2.1 0.7 4.2 0.4 1.9 0.8 4.2 0.4 287 32 270 255 24.1 0.1 24.7 23.8 07/22/2005 14:20:00 1.7 1.3 5.3 0.4 2.1 1.2 5.3 0.4 2 1.1 5.3 0.4 321 32 294 255 24.7 0.1 25 24.7 07/22/2005 14:30:00 2.4 1.3 5.7 0.4 2.8 1.2 5.7 0.4 2.1 1.1 4.9 0.4 308 38 326 255 25.3 0 25.6 25 07/22/2005 14:40:00 3 1 4.9 0.4 3.2 0.9 5.3 0.4 2.7 1 4.9 0.4 308 22 317 255 25.6 0 25.6 25.3 07/22/2005 14:50:00 3.5 1.1 6.5 0.7 3.8 1 6.5 1.1 3.4 1 5.7 1.1 303 21 325 255 24.9 0 25.3 24.7 07/22/2005 15:00:00 2.6 1.2 5.3 0.4 3 1.1 5.3 0.4 2.6 1.1 5.3 0.4 304 22 297 255 24.6 0 25 24.4 07/22/2005 15:10:00 4.2 1.4 6.5 0.7 4.5 1.3 6.8 1.5 3.9 1.3 6.5 1.1 292 20 288 255 24.4 0 25 24.1 07/22/2005 15:20:00 3.4 1.1 5.3 0.4 3.7 1 6.1 0.7 3.2 1 6.1 0.7 306 24 284 255 24.7 0.2 25 24.4 07/22/2005 15:30:00 3.7 1 6.5 1.5 4 0.9 6.8 1.9 3.6 0.9 6.1 1.9 289 19 280 255 24.9 0 25 24.7 07/22/2005 15:40:00 3 1.2 6.1 0.4 3.4 1.1 6.5 0.7 2.8 1.3 6.8 0.4 284 26 262 255 24.7 0 25 24.4 07/22/2005 15:50:00 2.4 1.1 4.9 0.4 2.8 1 5.7 0.4 2.4 0.9 5.7 0.4 287 24 291 255 24.8 0.1 25.3 24.7 07/22/2005 16:00:00 3.3 1.7 6.8 0.4 3.6 1.7 6.8 0.4 3.1 1.5 6.8 0.4 291 23 285 255 24.7 0 25 24.4 07/22/2005 16:10:00 3.5 1.2 6.1 0.7 3.9 1.2 6.5 1.5 3.3 1.3 6.1 0.4 294 19 277 255 24.3 0.2 25 23.8 07/22/2005 16:20:00 3 1.4 6.5 0.4 3.4 1.3 6.8 1.1 3 1.2 5.7 0.7 300 21 312 255 24.4 0 24.7 24.1 07/22/2005 16:30:00 2.3 1.2 5.3 0.4 2.8 1.3 5.3 0.4 2.2 1.2 6.1 0.4 287 32 324 255 24.7 0 25 24.7 07/22/2005 16:40:00 2.7 1 5.3 0.4 3.1 1 6.1 0.7 2.6 1 5.3 0.7 289 26 289 255 24.4 0.2 25 24.1 07/22/2005 16:50:00 2.5 1.1 5.3 0.4 3.1 1 5.3 0.7 2.5 1 4.9 0.7 281 26 283 255 24.1 0 24.4 24.1 07/22/2005 17:00:00 3 1.1 5.7 0.4 3.4 1.1 5.7 0.4 3 1.1 6.1 0.4 297 21 294 255 24.1 0 24.4 23.8 07/22/2005 17:10:00 2.5 1.3 6.1 0.4 3.1 1.2 6.5 1.1 2.5 1 5.7 0.4 274 28 289 255 23.8 0 24.1 23.8 07/22/2005 17:20:00 2.3 1.2 4.9 0.4 2.8 1.2 5.3 0.4 2.5 1.1 4.9 0.4 276 27 294 255 23.7 0 23.8 23.5 07/22/2005 17:30:00 2.4 1.1 4.9 0.4 3 1 5.3 0.4 2.4 1.1 5.3 0.4 288 27 287 255 23.4 0 23.5 23.5 07/22/2005 17:40:00 2.2 1 5.3 0.4 2.8 1 5.7 0.4 2.3 1 4.2 0.4 293 27 314 255 23.4 0 23.5 23.5 07/22/2005 17:50:00 1.8 1.2 5.3 0.4 2.4 1.2 6.1 0.4 2.2 1 4.9 0.4 275 29 220 255 23.5 0 23.5 23.5 07/22/2005 18:00:00 2 1 4.6 0.4 2.6 1 4.9 0.4 2.3 0.7 4.2 0.7 278 23 275 255 23.5 0 23.8 23.5 07/22/2005 18:10:00 2.1 1.2 4.9 0.4 2.8 1.1 5.3 0.4 2.2 1 4.6 0.4 287 28 286 255 23.7 0 23.8 23.5 07/22/2005 18:20:00 2.9 1.2 4.9 0.4 3.4 1 5.3 0.4 3 1.1 6.1 0.7 280 16 286 255 23.4 0 23.8 23.5 07/22/2005 18:30:00 2.6 1.1 4.9 0.4 3.2 1 5.3 0.4 2.8 1.1 4.9 0.4 280 29 287 255 23.2 0 23.5 23.2 07/22/2005 18:40:00 1.8 1.2 4.6 0.4 2.5 1.1 4.9 0.4 2.2 1.2 4.9 0.4 285 28 297 255 23 0 23.5 22.9 07/22/2005 18:50:00 2.1 1.1 4.9 0.4 2.7 1 4.9 0.4 2.3 1 4.9 0.4 285 23 263 255 22.8 0 23.2 22.6 07/22/2005 19:00:00 1.8 1.1 4.6 0.4 2.4 1.1 4.6 0.4 2.2 1 4.9 0.4 284 30 288 255 22.6 0 22.9 22.3 07/22/2005 19:10:00 1.4 0.9 3.8 0.4 2 0.9 4.2 0.4 1.8 0.7 3.4 0.4 287 22 293 255 22.3 0 22.9 22 07/22/2005 19:20:00 1.3 0.9 4.6 0.4 2 1 4.6 0.4 1.9 0.8 4.2 0.4 277 21 259 255 21.9 0.1 22.3 21.7 07/22/2005 19:30:00 1.4 0.9 3.4 0.4 2.2 0.9 4.6 0.4 1.8 0.9 3.8 0.4 254 18 261 255 21.7 0 22 21.4 07/22/2005 19:40:00 0.8 0.6 3 0.4 1.5 0.9 3.8 0.4 1.1 0.6 3 0.4 251 20 294 255 21.2 0.3 22 20.5 07/22/2005 19:50:00 0.4 0.2 1.5 0.4 1 0.6 2.6 0.4 0.8 0.4 1.9 0.4 268 12 255 255 20.3 0.3 21.1 19.7 07/22/2005 20:00:00 0.4 0.1 0.7 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 260 5 266 255 19.4 0.2 20.3 18.8 07/22/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 277 38 255 255 18.8 0.2 19.4 18.5 07/22/2005 20:20:00 0.4 0.2 1.1 0.4 0.9 0.5 2.3 0.4 1 0.4 1.9 0.4 46 15 56 255 18.5 0.1 19.1 18.2 07/22/2005 20:30:00 0.6 0.4 1.5 0.4 1.4 0.5 2.3 0.4 1.2 0.5 2.6 0.4 45 8 34 255 18.1 0.1 19.1 17.7 07/22/2005 20:40:00 1.5 0.5 2.6 0.4 2.2 0.4 3 0.7 1.9 0.4 3 0.7 42 8 40 255 17.9 0 18 17.7 07/22/2005 20:50:00 0.9 0.4 1.9 0.4 1.8 0.4 2.6 0.7 1.4 0.5 2.6 0.4 26 11 25 255 18.1 0 18.2 18 07/22/2005 21:00:00 0.4 0.1 1.1 0.4 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 22 5 27 255 17.7 0 18 17.4 07/22/2005 21:10:00 0.4 0 0.7 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 45 11 59 255 17.3 0 17.4 17.1 07/22/2005 21:20:00 0.5 0.3 1.5 0.4 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 48 12 40 255 17 0 17.1 16.8 07/22/2005 21:30:00 0.6 0.3 1.5 0.4 1.4 0.5 2.3 0.4 1.1 0.6 2.6 0.4 26 9 28 255 16.4 0.2 16.8 16.3 07/22/2005 21:40:00 0.4 0.1 1.1 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 33 11 12 255 16 0 16.3 16 07/22/2005 21:50:00 0.5 0.3 1.5 0.4 1.2 0.5 2.6 0.4 0.8 0.6 2.6 0.4 34 11 35 255 15.7 0.1 16.3 15.5 07/22/2005 22:00:00 0.4 0.2 1.5 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 40 6 34 255 15.1 0 15.7 14.9 07/22/2005 22:10:00 0.6 0.4 1.5 0.4 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 38 9 46 255 14.6 0 14.9 14.4 07/22/2005 22:20:00 0.7 0.5 2.3 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 29 15 41 255 14.3 0.2 14.6 13.8 07/22/2005 22:30:00 0.4 0 0.7 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 32 10 16 255 14.2 0.1 14.6 13.8 07/22/2005 22:40:00 0.4 0 0.7 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.1 0.4 40 7 9 255 13.8 0 14.4 13.5 07/22/2005 22:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 18 7 255 255 13.3 0.2 13.8 12.7 07/22/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 14 0 255 255 12.8 0 13 12.7 07/22/2005 23:10:00 0.4 0 0.7 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 359 15 14 255 12.6 0.1 13.3 12.5 07/22/2005 23:20:00 0.4 0.1 0.7 0.4 0.5 0.4 1.9 0.4 0.4 0.1 1.5 0.4 309 27 291 255 12.3 0 12.7 12.2 07/22/2005 23:30:00 0.5 0.3 1.9 0.4 1.1 0.6 2.6 0.4 0.6 0.4 2.3 0.4 278 7 279 255 12.1 0.1 12.5 11.9 07/22/2005 23:40:00 0.6 0.4 1.9 0.4 1.1 0.7 2.6 0.4 0.6 0.4 1.9 0.4 293 13 271 255 11.9 0.1 12.5 11.7 07/22/2005 23:50:00 0.4 0.1 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 307 15 314 255 11.7 0 11.9 11.7 07/23/2005 00:00:00 0.4 0.1 1.5 0.4 0.7 0.4 2.3 0.4 0.5 0.2 1.5 0.4 308 12 281 255 11.5 0 11.9 11.4 07/23/2005 00:10:00 0.4 0.2 1.1 0.4 1 0.5 2.3 0.4 0.5 0.2 1.1 0.4 285 8 289 255 11.3 0 11.7 11.1 07/23/2005 00:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 272 9 255 255 11.2 0 11.7 11.1 07/23/2005 00:30:00 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 0.4 0.1 0.7 0.4 222 19 255 255 11.2 0 11.7 11.1 07/23/2005 00:40:00 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 85 49 255 255 11.2 0 11.7 11.1 07/23/2005 00:50:00 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 0.8 0.2 1.1 0.4 81 0 255 255 11.1 0 11.7 10.9 07/23/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 81 0 255 255 11.1 0 11.7 10.9 07/23/2005 01:10:00 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 144 38 255 255 11.2 0 11.7 11.1 07/23/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 11.1 0 11.7 10.9 07/23/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 10.8 0.1 11.4 10.6 07/23/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 10.7 0 11.1 10.6 07/23/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 10.6 0 10.9 10.6 07/23/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 10.6 0 10.6 10.6 07/23/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 255 255 10.6 0 10.6 10.6 07/23/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 12 255 255 10.5 0 10.6 10.3 07/23/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 255 255 10.5 0 10.6 10.3 07/23/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 255 255 10.4 0 10.6 10.3 07/23/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 255 255 10.3 0 10.6 10.3 07/23/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 138 0 255 255 10.3 0 10.3 10.3 07/23/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 128 9 255 255 10.1 0 10.3 10.1 07/23/2005 03:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 119 0 255 255 10.2 0 10.3 10.1 07/23/2005 03:30:00 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 1.1 0.4 1.9 0.4 119 0 255 255 10.2 0 10.3 10.1 07/23/2005 03:40:00 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 109 4 255 255 9.9 0 10.1 9.8 07/23/2005 03:50:00 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 1.1 0.3 1.5 0.4 107 0 255 255 9.8 0 10.1 9.8 07/23/2005 04:00:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 1.3 0.3 1.9 0.7 115 11 255 255 10 0 10.3 9.8 07/23/2005 04:10:00 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 1.6 0.3 2.3 0.7 137 3 143 255 9.8 0 9.8 9.8 07/23/2005 04:20:00 0.4 0 0.7 0.4 1 0.3 1.9 0.4 1.5 0.3 2.3 0.7 134 4 136 255 9.9 0 10.1 9.8 07/23/2005 04:30:00 0.4 0.2 1.5 0.4 1.1 0.5 2.3 0.4 1.2 0.3 1.9 0.4 130 7 113 255 10 0 10.1 9.8 07/23/2005 04:40:00 0.4 0.1 0.7 0.4 0.8 0.5 2.3 0.4 0.9 0.5 1.9 0.4 117 28 119 255 10.2 0 10.3 10.1 07/23/2005 04:50:00 0.4 0.1 1.1 0.4 1 0.5 1.9 0.4 0.9 0.4 1.5 0.4 48 16 49 255 10.3 0 10.6 10.3 07/23/2005 05:00:00 0.6 0.3 1.9 0.4 1.2 0.7 2.6 0.4 1 0.6 2.6 0.4 57 11 56 255 10.5 0 10.9 10.3 07/23/2005 05:10:00 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 66 10 71 255 10.9 0 11.1 10.9 07/23/2005 05:20:00 0.4 0.1 0.7 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 63 11 70 255 10.9 0 11.1 10.9 07/23/2005 05:30:00 0.4 0.1 1.1 0.4 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 71 10 89 255 10.9 0 11.1 10.9 07/23/2005 05:40:00 0.4 0 0.7 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 70 13 78 255 11.2 0 11.4 11.1 07/23/2005 05:50:00 0.4 0 0.7 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 74 5 68 255 11.5 0 11.7 11.4 07/23/2005 06:00:00 0.4 0.1 1.1 0.4 0.7 0.5 2.3 0.4 0.7 0.3 1.9 0.4 78 13 62 255 11.8 0 11.9 11.7 07/23/2005 06:10:00 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 78 11 67 255 12.1 0 12.7 11.9 07/23/2005 06:20:00 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 88 10 80 255 12.5 0 12.7 12.2 07/23/2005 06:30:00 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 54 18 67 255 12.9 0 13 12.7 07/23/2005 06:40:00 0.7 0.5 2.3 0.4 1.4 0.7 3 0.4 1.3 0.6 3 0.4 44 12 46 255 13.2 0 13.3 13 07/23/2005 06:50:00 0.6 0.5 2.3 0.4 1.4 0.6 3 0.4 1.5 0.4 2.6 0.4 41 12 51 255 13.5 0 14.1 13.3 07/23/2005 07:00:00 0.4 0.2 1.5 0.4 1.1 0.6 2.6 0.4 1.1 0.4 2.3 0.4 46 13 39 255 13.8 0 14.4 13.5 07/23/2005 07:10:00 0.4 0 0.7 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 59 17 65 255 14.2 0.2 14.9 13.8 07/23/2005 07:20:00 0.4 0.2 1.1 0.4 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 50 11 62 255 14.5 0 14.9 14.4 07/23/2005 07:30:00 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 58 13 56 255 14.4 0 14.9 14.4 07/23/2005 07:40:00 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 50 20 255 255 14.6 0.1 15.2 14.6 07/23/2005 07:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 49 18 255 255 14.9 0 15.5 14.6 07/23/2005 08:00:00 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.5 0.4 41 15 255 255 15.5 0 16 15.2 07/23/2005 08:10:00 0.4 0 0.7 0.4 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 35 11 33 255 16 0.1 16.6 15.7 07/23/2005 08:20:00 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 1.2 0.4 2.3 0.4 62 11 255 255 16.1 0.1 16.6 16 07/23/2005 08:30:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 55 30 255 255 17.1 0.4 18 16.3 07/23/2005 08:40:00 0.4 0 0.7 0.4 0.6 0.3 1.9 0.4 0.7 0.4 1.9 0.4 20 18 23 255 18.5 0.2 18.8 17.7 07/23/2005 08:50:00 0.4 0.1 0.7 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 15 33 310 255 19 0.1 20 18.8 07/23/2005 09:00:00 0.4 0.1 0.7 0.4 0.7 0.5 2.3 0.4 0.9 0.5 1.9 0.4 57 61 93 255 19.4 0 20 19.1 07/23/2005 09:10:00 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 336 66 28 255 19.6 0.1 20.3 19.4 07/23/2005 09:20:00 0.4 0.1 0.7 0.4 0.6 0.4 1.9 0.4 0.7 0.4 2.3 0.4 6 38 351 255 20.6 0.2 21.4 20 07/23/2005 09:30:00 0.4 0.2 1.1 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 352 19 26 255 20.8 0.1 21.1 20.5 07/23/2005 09:40:00 0.4 0.1 1.1 0.4 0.9 0.6 2.3 0.4 1 0.5 2.3 0.4 224 33 251 255 21 0 21.1 20.8 07/23/2005 09:50:00 0.6 0.5 2.3 0.4 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 232 28 235 255 20.6 0 20.8 20.5 07/23/2005 10:00:00 0.4 0.2 1.5 0.4 0.9 0.5 1.9 0.4 1.1 0.5 2.6 0.4 209 94 138 255 20.9 0 21.1 20.5 07/23/2005 10:10:00 0.6 0.5 2.6 0.4 1.3 0.5 3 0.4 1.3 0.5 2.3 0.4 8 19 27 255 21.3 0 21.7 21.1 07/23/2005 10:20:00 0.4 0.2 1.5 0.4 0.7 0.4 2.3 0.4 0.7 0.5 1.9 0.4 74 64 248 255 21.3 0 21.7 21.1 07/23/2005 10:30:00 0.4 0.2 1.5 0.4 0.9 0.5 2.3 0.4 0.8 0.6 2.3 0.4 283 86 194 255 21.7 0 22.3 21.4 07/23/2005 10:40:00 0.9 0.6 2.6 0.4 1.4 0.8 3.4 0.4 1.2 0.8 3.4 0.4 264 43 237 255 21.4 0 22 21.1 07/23/2005 10:50:00 1 0.6 3 0.4 1.6 0.7 3.4 0.4 1.4 0.7 3 0.4 277 32 260 255 21.6 0.1 22 21.1 07/23/2005 11:00:00 1.2 0.8 3 0.4 1.7 0.9 3.4 0.4 1.7 0.9 3.4 0.4 275 61 218 255 21.6 0 22 21.4 07/23/2005 11:10:00 0.7 0.6 2.6 0.4 1 0.7 3 0.4 0.9 0.6 2.6 0.4 334 51 319 255 21.8 0.1 22.3 21.7 07/23/2005 11:20:00 1.3 1 3.8 0.4 1.8 1 4.2 0.4 1.5 0.9 3.4 0.4 276 32 270 255 22.3 0 22.9 22 07/23/2005 11:30:00 1.6 0.8 3.4 0.4 2.1 0.7 4.2 0.7 1.8 0.8 3.4 0.4 289 33 311 255 22.7 0 22.9 22.6 07/23/2005 11:40:00 1.8 1.2 5.3 0.4 2.1 1.1 5.3 0.4 1.9 1 4.9 0.4 285 49 307 255 22.7 0.1 22.9 22.3 07/23/2005 11:50:00 0.8 0.6 3 0.4 1.3 0.6 3 0.4 1.2 0.5 2.6 0.4 298 43 305 255 22.4 0.1 22.9 22.3 07/23/2005 12:00:00 1.8 1 3.8 0.4 2.1 1 3.8 0.4 1.8 1.1 4.6 0.4 272 45 273 255 22.5 0 22.9 22.3 07/23/2005 12:10:00 1.4 1.1 4.2 0.4 1.7 1.1 4.6 0.4 1.5 1.1 4.6 0.4 292 32 305 255 22.4 0.2 22.9 22 07/23/2005 12:20:00 1.6 0.9 3.4 0.4 1.8 0.8 3.8 0.4 1.6 0.8 3.4 0.4 329 35 323 255 23 0.2 23.5 22.9 07/23/2005 12:30:00 0.9 0.9 3.8 0.4 1.3 0.8 3.8 0.4 1.1 0.8 3.8 0.4 297 98 307 255 23.1 0 23.5 22.9 07/23/2005 12:40:00 2 1 4.6 0.4 2.3 1 4.6 0.4 1.9 1.1 4.2 0.4 291 30 267 255 23.3 0 23.5 23.2 07/23/2005 12:50:00 2.6 0.8 4.6 0.4 2.7 0.7 4.6 1.1 2.4 0.7 4.2 0.7 321 23 314 255 23.5 0 23.8 23.5 07/23/2005 13:00:00 1.7 1 3.8 0.4 2 1 3.8 0.4 1.8 1 4.2 0.4 307 38 291 255 23.4 0 23.8 23.2 07/23/2005 13:10:00 1.8 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.5 0.7 3 0.4 263 51 259 255 23.8 0.3 24.4 23.5 07/23/2005 13:20:00 1.7 0.7 3.4 0.4 1.9 0.6 3.4 0.4 1.4 0.7 3 0.4 307 39 352 255 24.1 0.2 24.7 23.8 07/23/2005 13:30:00 1.8 0.8 3.8 0.4 2 0.8 3.8 0.4 1.7 0.7 4.2 0.4 299 82 318 255 24.4 0 24.7 24.1 07/23/2005 13:40:00 2.3 0.8 4.2 0.4 2.4 0.7 3.8 0.7 2.1 0.6 3.8 0.7 335 20 325 255 24.3 0 24.4 24.1 07/23/2005 13:50:00 2 1 4.2 0.4 2.2 0.9 4.2 0.4 1.8 0.9 3.8 0.4 327 45 302 255 24.1 0 24.4 23.8 07/23/2005 14:00:00 2.4 0.8 4.2 0.4 2.6 0.7 4.2 0.4 2.2 0.6 3.8 0.7 356 23 285 255 24.3 0 24.7 23.8 07/23/2005 14:10:00 2 1.1 4.2 0.4 2.2 1 4.6 0.4 1.7 0.8 3.8 0.4 302 21 298 255 24.4 0 25 24.1 07/23/2005 14:20:00 2.5 0.9 4.6 0.4 2.6 0.8 4.6 0.4 2.1 1 4.2 0.4 299 27 306 255 24.5 0 24.7 24.4 07/23/2005 14:30:00 2.4 1 4.9 0.4 2.5 1 4.9 0.4 2.2 1 4.6 0.4 304 32 303 255 24.3 0 24.7 24.1 07/23/2005 14:40:00 3.1 1 4.9 0.4 3.1 1 4.9 0.4 2.7 1 5.7 0.4 293 21 302 255 24.4 0 24.7 24.4 07/23/2005 14:50:00 2.9 0.8 4.9 0.4 3 0.8 4.6 0.4 2.6 0.8 4.6 0.4 297 23 321 255 24.5 0 24.7 24.4 07/23/2005 15:00:00 2.1 0.8 4.2 0.4 2 0.8 4.2 0.4 1.8 0.8 4.2 0.4 321 26 323 255 24.5 0 25 24.4 07/23/2005 15:10:00 3.3 0.8 4.9 1.1 3.3 0.8 4.9 1.1 2.7 0.9 4.9 0.4 297 22 288 255 24.1 0.3 25 23.8 07/23/2005 15:20:00 3.7 0.7 5.3 1.5 3.6 0.7 4.9 1.5 3.2 0.8 5.3 0.7 314 19 330 255 23.6 0 23.8 23.5 07/23/2005 15:30:00 2.9 0.8 4.9 1.1 2.7 0.8 4.9 1.1 2.1 1 4.6 0.4 339 22 358 255 23.3 0.3 23.8 22.9 07/23/2005 15:40:00 3 0.8 4.6 1.1 2.9 0.8 4.9 1.1 1.9 1 4.2 0.4 347 15 335 255 22.5 0.1 22.9 22.3 07/23/2005 15:50:00 2.3 0.8 4.2 0.4 2.2 0.9 4.6 0.4 1.6 0.8 4.2 0.4 338 21 345 255 22.2 0 22.3 22.3 07/23/2005 16:00:00 2.5 0.8 3.8 0.4 2.2 0.7 3.8 0.4 1.7 0.9 3.8 0.4 342 14 324 255 22 0.1 22.3 21.7 07/23/2005 16:10:00 2.6 0.9 4.6 0.4 2.3 0.7 4.2 0.4 1.9 0.8 4.2 0.4 344 15 340 255 21.6 0 21.7 21.4 07/23/2005 16:20:00 2.6 0.7 4.2 0.7 2.6 0.8 4.2 0.7 1.7 1 3.8 0.4 0 17 6 255 21.9 0 22.3 21.7 07/23/2005 16:30:00 2.4 0.8 3.8 0.7 2.2 0.8 3.8 0.4 1.5 0.8 3.8 0.4 346 18 324 255 22.2 0 22.6 22 07/23/2005 16:40:00 2.5 0.6 4.6 1.1 2.2 0.7 4.6 0.4 1.7 0.7 3.4 0.4 344 17 348 255 22.3 0 22.9 22 07/23/2005 16:50:00 2.3 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.4 0.7 3 0.4 1 19 15 255 22.2 0 22.9 22 07/23/2005 17:00:00 2.2 0.6 3.4 0.7 2 0.7 3.8 0.4 1.2 0.6 2.6 0.4 345 22 329 255 21.9 0.2 22.3 21.4 07/23/2005 17:10:00 2.1 0.6 3.4 0.7 1.8 0.7 3 0.4 1.6 0.7 3 0.4 326 27 313 255 21.5 0 22 21.4 07/23/2005 17:20:00 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 295 20 284 255 21.5 0 22 21.4 07/23/2005 17:30:00 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 2.3 0.4 264 18 297 255 21.6 0 21.7 21.1 07/23/2005 17:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 280 24 255 255 21.3 0 21.4 21.1 07/23/2005 17:50:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 237 14 240 255 21.3 0 21.7 21.1 07/23/2005 18:00:00 1.1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 226 7 224 255 21.6 0 21.7 21.4 07/23/2005 18:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 226 11 219 255 21.6 0 21.7 21.4 07/23/2005 18:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 222 2 218 255 21.3 0 21.7 21.1 07/23/2005 18:30:00 0.7 0.6 3 0.4 0.6 0.6 2.6 0.4 0.4 0.2 1.5 0.4 253 69 7 255 20.8 0.2 21.4 20.3 07/23/2005 18:40:00 1.9 0.6 3.4 0.4 1.7 0.7 3 0.4 1.1 0.7 3 0.4 357 10 355 255 20 0.3 20.8 19.4 07/23/2005 18:50:00 1.9 0.5 3 0.4 1.7 0.5 3.4 0.4 1.1 0.6 2.6 0.4 338 24 4 255 19.5 0 20.3 19.4 07/23/2005 19:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 321 1 311 255 19.4 0 20 19.1 07/23/2005 19:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 0 321 255 19.5 0 20 19.4 07/23/2005 19:20:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.4 0.2 1.5 0.4 5 13 10 255 19.1 0 19.7 18.8 07/23/2005 19:30:00 1 0.8 2.6 0.4 0.9 0.8 2.6 0.4 0.8 0.6 2.3 0.4 49 30 85 255 18.5 0.1 19.1 18.2 07/23/2005 19:40:00 2.2 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.7 0.6 3 0.4 55 13 59 255 18.1 0.1 18.2 17.7 07/23/2005 19:50:00 2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.6 2.6 0.4 51 14 58 255 17.8 0 18 17.4 07/23/2005 20:00:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.6 2.3 0.4 38 12 39 255 17.5 0 17.7 17.1 07/23/2005 20:10:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 15 36 50 255 17.3 0 17.4 17.1 07/23/2005 20:20:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 65 23 38 255 17.1 0 17.1 16.8 07/23/2005 20:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 58 8 72 255 16.9 0 17.1 16.8 07/23/2005 20:40:00 2.2 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.4 0.6 3 0.4 64 9 60 255 16.7 0 16.8 16.6 07/23/2005 20:50:00 2.7 0.5 4.2 1.1 2.5 0.6 4.2 1.1 1.8 0.6 3.4 0.4 61 16 32 255 16.6 0 16.8 16.6 07/23/2005 21:00:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.1 1.8 0.5 3 0.4 65 12 68 255 16.6 0 16.8 16.6 07/23/2005 21:10:00 2.6 0.6 3.8 1.5 2.4 0.6 4.2 0.7 1.8 0.6 3.4 0.4 63 13 74 255 16.5 0 16.8 16.3 07/23/2005 21:20:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2 0.5 3 0.4 56 13 63 255 16.4 0.1 16.8 16.3 07/23/2005 21:30:00 2.5 0.4 3.8 1.5 2.3 0.5 3.8 1.1 1.9 0.4 3 0.4 62 11 80 255 16.1 0 16.8 16 07/23/2005 21:40:00 2.7 0.5 3.8 1.5 2.5 0.6 3.8 1.1 1.9 0.5 3.4 0.7 61 11 62 255 15.8 0 16.3 15.7 07/23/2005 21:50:00 2.9 0.5 4.2 1.9 2.8 0.5 4.6 1.5 2.1 0.5 3.8 0.7 63 11 69 255 15.6 0 16 15.5 07/23/2005 22:00:00 3 0.5 4.2 1.5 2.9 0.6 4.6 1.5 2.1 0.5 3.8 1.1 62 12 52 255 15.3 0.1 15.7 15.2 07/23/2005 22:10:00 3.1 0.6 4.6 1.5 3 0.6 4.6 1.5 2.3 0.6 3.8 0.7 62 11 70 255 15.2 0.2 15.7 14.6 07/23/2005 22:20:00 3 0.5 4.6 1.9 2.9 0.5 4.6 1.5 2.2 0.6 3.4 0.7 60 12 73 255 14.8 0.1 15.2 14.6 07/23/2005 22:30:00 2.9 0.5 4.2 1.5 2.9 0.6 4.2 1.5 2.2 0.6 4.2 1.1 62 11 60 255 14.4 0.2 15.2 14.1 07/23/2005 22:40:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.5 2.3 0.6 3.8 1.1 60 12 37 255 14.1 0.2 14.6 13.8 07/23/2005 22:50:00 3.1 0.5 4.6 1.9 3 0.6 4.2 1.5 2.2 0.5 3.8 0.7 64 12 52 255 13.4 0.3 14.6 13 07/23/2005 23:00:00 3.2 0.6 4.6 1.9 3 0.6 4.6 1.5 2.1 0.6 3.8 0.7 54 13 56 255 13.1 0 13.3 12.7 07/23/2005 23:10:00 2.6 0.5 3.8 1.5 2.4 0.6 3.8 0.7 1.9 0.5 3 0.4 54 13 36 255 12.6 0 12.7 12.2 07/23/2005 23:20:00 2.8 0.5 4.6 1.5 2.6 0.6 4.6 1.1 2 0.6 3.8 0.7 47 11 25 255 12.3 0 13 11.9 07/23/2005 23:30:00 3.1 0.6 4.9 1.9 3 0.7 4.9 1.9 2.3 0.7 4.2 0.7 42 10 41 255 12.8 0 13.3 12.5 07/23/2005 23:40:00 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 1 0.6 2.6 0.4 46 11 57 255 12.3 0.2 13.3 11.9 07/23/2005 23:50:00 1.5 0.9 3 0.4 1.2 0.8 3 0.4 1 0.6 2.3 0.4 56 15 56 255 11.7 0 12.2 11.7 07/24/2005 00:00:00 2.7 0.4 3.8 1.5 2.4 0.5 3.4 1.1 1.7 0.6 3 0.4 74 17 68 255 11.7 0 11.9 11.7 07/24/2005 00:10:00 1.9 0.4 3 0.7 1.6 0.5 2.6 0.4 1 0.5 2.6 0.4 76 10 68 255 11.5 0 11.9 11.4 07/24/2005 00:20:00 1.6 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.6 0.3 1.5 0.4 95 16 92 255 11.3 0 11.9 11.1 07/24/2005 00:30:00 1.3 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.4 1.9 0.4 103 6 93 255 11 0 11.7 10.9 07/24/2005 00:40:00 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 93 12 96 255 10.7 0.1 11.1 10.6 07/24/2005 00:50:00 2.1 0.4 3 1.1 1.7 0.4 2.6 0.4 1 0.4 1.9 0.4 89 8 90 255 10.7 0 11.1 10.6 07/24/2005 01:00:00 2.1 0.6 3.8 1.1 1.7 0.7 3.8 0.4 0.9 0.5 2.3 0.4 87 13 79 255 10.3 0.1 10.6 10.3 07/24/2005 01:10:00 1.4 0.4 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 111 13 122 255 10.2 0 10.3 10.1 07/24/2005 01:20:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 73 15 86 255 10.1 0 10.3 9.8 07/24/2005 01:30:00 2.2 0.5 3.8 0.7 1.9 0.6 3.8 0.4 1 0.5 2.3 0.4 90 22 74 255 9.8 0 10.6 9.6 07/24/2005 01:40:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 1.1 0.5 2.3 0.4 103 28 77 255 9.7 0 9.8 9.6 07/24/2005 01:50:00 2 0.9 3.8 0.4 1.7 1 3.8 0.4 1 0.7 3.4 0.4 66 30 62 255 9.8 0 10.3 9.6 07/24/2005 02:00:00 1.2 0.6 3.4 0.4 0.8 0.6 3.4 0.4 0.7 0.4 2.3 0.4 68 35 24 255 9.6 0 9.8 9.6 07/24/2005 02:10:00 2.3 0.7 4.2 0.4 2 0.7 3.8 0.4 1.6 0.6 3 0.4 89 24 48 255 9.6 0 9.6 9.6 07/24/2005 02:20:00 2.6 0.5 3.8 1.1 2.3 0.5 3.8 0.7 1.4 0.7 3 0.4 102 12 101 255 9.5 0 9.8 9.6 07/24/2005 02:30:00 2.9 0.6 4.2 1.5 3.2 0.6 4.9 1.5 1.9 0.7 3.4 0.4 89 13 88 255 9.4 0 9.8 9.3 07/24/2005 02:40:00 2.6 0.5 4.2 1.5 3 0.6 4.6 1.5 2 0.7 4.2 0.4 87 11 86 255 9.2 0 9.6 9 07/24/2005 02:50:00 2.6 0.5 3.8 1.5 3.1 0.6 4.6 1.5 1.9 0.8 3.4 0.4 90 11 91 255 9.2 0 9.3 9 07/24/2005 03:00:00 2.4 0.6 3.8 0.7 2.7 0.7 4.2 0.4 1.5 0.8 3.8 0.4 88 14 96 255 9.3 0 9.3 9.3 07/24/2005 03:10:00 2.6 0.4 3.8 1.9 3.2 0.4 4.6 1.9 2.2 0.6 3.8 0.7 91 9 86 255 9.3 0 9.3 9.3 07/24/2005 03:20:00 2.7 0.5 4.2 1.9 3.3 0.6 4.9 2.3 2.5 0.6 4.2 1.1 88 10 89 255 9.5 0.1 9.8 9.3 07/24/2005 03:30:00 3.3 0.6 4.9 1.9 4 0.6 5.3 2.3 3 0.6 4.6 1.5 78 9 81 255 10 0.1 10.3 9.6 07/24/2005 03:40:00 2.8 0.5 4.2 1.9 3.5 0.6 5.3 1.9 2.6 0.6 3.8 0.7 68 11 62 255 10.6 0.1 10.9 10.3 07/24/2005 03:50:00 2.4 0.4 3.8 1.5 2.9 0.6 4.6 1.5 2.1 0.5 4.2 0.7 65 11 54 255 10.5 0.2 10.9 10.3 07/24/2005 04:00:00 3 0.6 4.9 1.1 3.5 0.8 5.3 0.7 2.4 0.7 4.2 0.7 83 12 55 255 10 0 10.3 9.8 07/24/2005 04:10:00 3.7 0.6 5.3 2.3 4.4 0.6 5.7 2.6 3.3 0.6 4.9 1.5 77 9 72 255 10.3 0.2 10.6 9.8 07/24/2005 04:20:00 2.6 0.5 4.2 1.5 3 0.8 4.9 1.1 2.5 0.6 4.6 1.1 69 13 64 255 10.9 0.3 11.4 10.6 07/24/2005 04:30:00 2.3 0.6 3.8 0.7 2 0.7 3.8 0.4 1.3 0.7 2.6 0.4 68 15 68 255 11.1 0.3 11.7 10.6 07/24/2005 04:40:00 1.6 0.6 3 0.4 1.2 0.6 3 0.4 0.7 0.5 2.3 0.4 72 15 55 255 10.3 0.2 10.6 9.8 07/24/2005 04:50:00 2.6 0.6 4.6 1.1 2.6 0.8 4.9 0.7 1.6 0.7 3.4 0.4 86 13 77 255 9.8 0 10.1 9.6 07/24/2005 05:00:00 3.1 0.8 5.3 0.7 3.7 0.9 6.1 0.4 2.8 0.9 4.9 0.4 82 12 74 255 10 0.3 10.6 9.6 07/24/2005 05:10:00 3.6 0.8 5.7 1.9 4.2 0.9 6.1 1.5 3.6 0.8 6.1 1.9 55 18 80 255 11.7 0.6 12.5 10.6 07/24/2005 05:20:00 4.4 1.1 7.6 2.3 4.9 1.1 7.6 2.3 4 1 6.8 1.5 60 17 55 255 13 0.1 13.3 12.5 07/24/2005 05:30:00 4.2 1.2 7.2 2.3 4.8 1.2 7.6 2.6 4 1.1 7.2 1.5 61 15 66 255 13.7 0 13.8 13.3 07/24/2005 05:40:00 3.4 0.9 5.7 1.9 4 0.9 6.5 1.9 3.3 0.8 5.7 1.1 74 15 51 255 13.8 0 13.8 13.5 07/24/2005 05:50:00 3.5 0.8 5.7 1.9 4.1 0.8 6.1 1.9 3.4 0.7 5.3 1.9 84 12 88 255 13.5 0 13.8 13.3 07/24/2005 06:00:00 3.5 1 6.5 1.5 4.1 1 8 1.5 3.3 1.1 6.1 1.1 83 15 88 255 14.2 0.4 15.2 13.5 07/24/2005 06:10:00 3.7 1 6.1 1.5 4.3 1 6.5 1.9 3.5 1 5.7 1.1 76 15 67 255 15.2 0.1 15.7 14.9 07/24/2005 06:20:00 3.8 1.1 7.6 1.9 4.3 1.1 8.4 1.5 3.6 1 6.5 1.5 70 17 87 255 15.2 0 15.7 15.2 07/24/2005 06:30:00 3.5 1 5.7 1.1 3.9 1 6.1 1.1 3.5 0.9 5.7 1.5 65 17 88 255 15.6 0.1 16.3 15.5 07/24/2005 06:40:00 3.4 1 6.1 0.7 3.9 1 6.5 1.1 3.3 1 5.7 0.7 73 18 34 255 16 0 16.6 16 07/24/2005 06:50:00 3.7 1.2 7.6 0.7 4.2 1.1 8 1.9 3.5 1.2 7.2 1.1 67 18 62 255 16.2 0.1 16.8 16.3 07/24/2005 07:00:00 3.6 1.1 6.5 1.5 4.1 1.1 7.2 1.1 3.4 1 6.1 0.7 66 17 73 255 16.6 0 16.8 16.6 07/24/2005 07:10:00 4.3 1 6.8 2.3 4.8 1 7.2 3 3.9 1 6.8 1.5 62 17 61 255 16.9 0 17.1 16.8 07/24/2005 07:20:00 5.5 1.3 8.4 1.9 5.9 1.2 8.4 1.9 4.6 1.3 8 1.5 56 15 53 255 16.8 0 16.8 16.8 07/24/2005 07:30:00 4.6 1.2 8.4 1.9 5 1 8.8 2.3 4.3 1.2 8.4 1.9 56 18 76 255 17.2 0 17.4 16.8 07/24/2005 07:40:00 3.7 1.1 6.5 1.1 4.3 1.1 6.8 1.5 3.7 1 6.5 1.1 55 21 65 255 17.5 0 18 17.1 07/24/2005 07:50:00 4.5 1.4 7.6 1.9 5 1.3 8 1.9 4.3 1.3 7.2 1.1 57 18 55 255 18 0 18.2 17.7 07/24/2005 08:00:00 4.4 1.2 7.6 1.5 4.8 1.1 8.4 2.3 4.1 1.1 6.8 1.9 53 17 59 255 18.2 0.1 19.1 18 07/24/2005 08:10:00 4.8 1.1 7.6 2.3 5.2 1 8 2.6 4.4 1.2 8 1.9 42 17 49 255 18.9 0 19.4 18.5 07/24/2005 08:20:00 5 1.2 8 1.9 5.4 1.2 8.4 2.6 4.7 1.2 8 1.9 42 18 45 255 19.1 0.1 19.7 18.8 07/24/2005 08:30:00 4.2 1.7 9.1 1.9 4.7 1.5 9.5 1.5 3.8 1.5 8.4 0.7 48 22 57 255 19.6 0.3 20.3 19.1 07/24/2005 08:40:00 5.7 1.3 8.8 2.6 6 1.2 9.1 2.3 5.3 1.1 8 2.6 39 15 12 255 19.7 0 20.3 19.4 07/24/2005 08:50:00 5.6 1.1 8 2.6 6 1 8.4 3.4 4.9 1 7.6 2.3 46 16 80 255 20.1 0 20.5 19.7 07/24/2005 09:00:00 5.7 1.4 9.5 1.9 6.1 1.3 9.5 3 4.9 1.4 8.4 1.9 39 19 41 255 20.8 0.3 21.4 20.3 07/24/2005 09:10:00 6.2 1.5 9.9 2.6 6.4 1.4 9.9 3 5.4 1.4 10.3 1.9 35 17 44 255 20.2 0 20.5 20 07/24/2005 09:20:00 6 1.6 9.9 2.3 6.4 1.5 10.3 3 5.3 1.3 8.4 2.3 29 15 16 255 20.1 0.2 20.5 19.4 07/24/2005 09:30:00 5.7 1.7 10.3 1.5 6 1.7 9.9 1.9 5 1.8 9.1 1.9 24 15 21 255 19.3 0 20 19.1 07/24/2005 09:40:00 5.3 1.1 8.4 2.3 5.6 1 8.8 3 4.5 1.3 7.6 1.5 21 13 27 255 19.2 0 19.7 19.1 07/24/2005 09:50:00 4.6 1.1 8.4 2.3 5 1 8.4 3 4.1 1.1 7.6 1.9 24 15 358 255 20 0.2 20.8 19.4 07/24/2005 10:00:00 5.1 1.2 8.4 1.9 5.5 1.2 8.8 1.9 4.8 1.1 8 2.3 37 15 35 255 20 0 20.5 20 07/24/2005 10:10:00 6.2 1 9.1 3.8 6.5 0.9 9.1 4.2 5.4 1.1 8.4 2.6 34 13 31 255 20.1 0.1 20.8 20 07/24/2005 10:20:00 5.5 1.1 8 2.3 5.8 1 8.4 2.6 4.7 1.1 8 1.9 29 15 26 255 20.6 0.2 21.1 20.3 07/24/2005 10:30:00 5.3 1.1 8.4 1.9 5.6 1 8.4 2.3 4.6 1.3 8.4 1.5 30 15 46 255 21 0 21.4 20.8 07/24/2005 10:40:00 5.5 1.1 8 3 5.9 1 8 3.8 5 1.2 8.4 2.3 33 15 21 255 21.3 0.1 22 21.1 07/24/2005 10:50:00 5.2 1.2 8.8 2.6 5.6 1.1 9.1 3.4 4.6 1.1 8 2.3 26 13 35 255 20.8 0.3 21.7 20.3 07/24/2005 11:00:00 5.1 1.1 8.8 1.9 5.4 1 8.4 2.6 4.5 1.3 8 1.5 20 14 27 255 19.9 0.2 20.5 19.4 07/24/2005 11:10:00 4.2 1 6.8 1.9 4.6 1 7.2 1.5 3.5 1.3 6.8 0.7 17 15 349 255 20.1 0.2 20.8 19.7 07/24/2005 11:20:00 5 1.1 7.2 2.3 5.4 1 7.2 2.3 3.8 1.2 6.5 1.5 7 15 0 255 20.9 0.2 21.4 20.3 07/24/2005 11:30:00 5 1.2 8 1.9 5.4 1.2 8.4 1.9 3.9 1.3 7.2 1.1 4 14 349 255 21.6 0.1 22.3 21.1 07/24/2005 11:40:00 5 1.2 8.4 2.3 5.4 1.1 8.4 2.6 4 1.4 7.6 1.1 12 15 17 255 21.5 0 21.7 21.1 07/24/2005 11:50:00 6.3 1.8 10.3 1.9 6.5 1.7 10.7 2.3 4.9 1.9 9.5 0.7 13 19 27 255 22.1 0.2 22.9 21.7 07/24/2005 12:00:00 6.5 1.6 9.9 2.3 6.7 1.5 9.9 2.6 5.2 1.7 9.1 1.1 18 15 38 255 22.1 0.2 23.2 21.7 07/24/2005 12:10:00 4.9 1.8 9.9 1.9 5.3 1.7 9.9 1.9 3.7 1.7 9.9 0.4 4 18 17 255 21.8 0 22.3 21.7 07/24/2005 12:20:00 5.3 1.5 8.8 1.5 5.6 1.4 9.1 1.9 4.3 1.7 8.4 0.7 12 16 24 255 21.6 0 21.7 21.1 07/24/2005 12:30:00 5.9 1.1 8.4 1.9 6.2 1 8.4 1.9 4.7 1.3 8 0.7 10 12 25 255 21.1 0 21.4 20.8 07/24/2005 12:40:00 5.1 1.3 8.4 1.9 5.4 1.3 8.4 1.9 4.1 1.5 7.2 0.4 20 15 35 255 20.7 0.1 21.1 20.5 07/24/2005 12:50:00 5.8 1.1 8.8 2.6 6.1 1.1 9.1 3 4.7 1.3 7.2 1.1 19 12 19 255 20.8 0 21.1 20.5 07/24/2005 13:00:00 5.2 1.6 9.9 1.9 5.5 1.5 10.3 1.9 4.4 1.3 8.4 1.5 25 16 17 255 22.1 0.4 22.9 21.1 07/24/2005 13:10:00 6.6 1.2 9.5 2.3 6.8 1.1 9.5 3.4 5.6 1.5 9.9 1.5 22 14 29 255 22.4 0.1 22.9 22.3 07/24/2005 13:20:00 6.9 1.2 10.3 4.2 7.1 1.2 9.9 4.2 5.5 1.6 9.1 1.5 19 13 47 255 23.1 0 23.8 22.9 07/24/2005 13:30:00 6.6 1.1 9.9 3.4 6.9 1.1 9.5 4.2 6 1.2 9.1 3 27 10 34 255 22.1 0.4 23.2 21.7 07/24/2005 13:40:00 5.7 1.3 8.8 1.9 5.9 1.2 9.1 2.3 4.7 1.5 8 1.1 25 17 25 255 22.1 0.2 22.9 21.7 07/24/2005 13:50:00 5.5 1.5 9.1 2.3 5.8 1.5 9.1 2.6 4.5 1.8 8.8 0.4 21 17 26 255 22.2 0 22.3 22.3 07/24/2005 14:00:00 5.5 1.3 9.1 1.9 5.8 1.2 9.1 2.6 5.1 1.3 8.8 2.3 28 13 31 255 21.9 0.1 22.3 21.7 07/24/2005 14:10:00 6.1 1.1 8.8 3.4 6.3 1.1 8.8 3.4 5 1.3 8 1.5 22 13 26 255 21.6 0 21.7 21.4 07/24/2005 14:20:00 4.5 1.3 7.2 0.4 4.8 1.2 7.6 0.4 3.7 1.2 6.5 0.7 19 15 356 255 21.7 0 22 21.7 07/24/2005 14:30:00 5 1.2 8 1.9 5.3 1.2 8.4 2.6 4.2 1.5 8.4 1.5 22 13 23 255 21.7 0 22.3 21.4 07/24/2005 14:40:00 5.2 1 8.4 2.6 5.5 0.9 8 3 4.5 1.1 6.8 1.9 24 17 29 255 22.5 0 22.9 22.3 07/24/2005 14:50:00 4.9 1 7.2 2.3 5.2 0.9 7.6 2.3 4.2 1.1 6.8 1.1 19 13 34 255 22.5 0 22.9 22.3 07/24/2005 15:00:00 5.5 1.2 8.4 1.9 5.7 1.1 9.1 2.6 4.7 1.2 8 1.9 23 15 22 255 22.9 0.4 23.8 22.3 07/24/2005 15:10:00 5 1.2 8 2.3 5.2 1.2 8.8 2.3 3.9 1.3 7.2 0.7 17 19 358 255 23.8 0 24.4 23.5 07/24/2005 15:20:00 4.3 1.1 7.2 1.9 4.5 1.1 7.2 1.9 3.4 1.3 7.2 0.4 17 18 30 255 22.9 0.2 23.8 22.6 07/24/2005 15:30:00 4.8 1.6 8.8 1.9 4.8 1.7 9.1 1.1 3.5 1.8 9.1 0.4 14 21 63 255 23.2 0.1 23.5 22.9 07/24/2005 15:40:00 6.9 1.5 11.5 3.4 7.1 1.4 11.5 4.2 5.7 1.5 9.5 2.3 23 13 30 255 23.2 0.2 23.5 22.9 07/24/2005 15:50:00 6.4 1.5 9.9 1.9 6.6 1.5 10.3 2.3 5.4 1.8 9.5 1.1 22 17 31 255 22.5 0.2 23.2 22.3 07/24/2005 16:00:00 8 1.3 12.2 4.2 8.2 1.3 13 4.2 6.6 1.7 11.5 2.3 21 13 26 255 22.9 0 23.5 22.9 07/24/2005 16:10:00 7.8 1.3 11.1 5.3 7.9 1.3 11.1 4.6 6.4 1.9 10.7 1.5 22 13 22 255 23.3 0.1 23.5 22.9 07/24/2005 16:20:00 7.6 1.7 11.8 4.2 7.8 1.6 12.6 4.6 6.1 1.8 11.1 2.3 18 14 1 255 22 0.3 22.9 21.7 07/24/2005 16:30:00 7.9 1.5 11.8 4.2 8.1 1.4 11.8 4.9 6.5 1.7 10.7 1.9 22 14 6 255 22.6 0 22.9 22.3 07/24/2005 16:40:00 8.1 1.5 12.2 3 8.2 1.4 11.8 4.2 6.6 1.8 11.1 1.5 22 13 35 255 22.9 0.3 23.5 22.3 07/24/2005 16:50:00 6.9 1.7 11.1 2.3 7.1 1.7 11.1 2.6 5.9 2.2 11.8 1.9 21 15 12 255 21.6 0.3 22.3 21.1 07/24/2005 17:00:00 7.6 1.7 12.2 2.3 7.7 1.5 12.2 3 6.2 1.7 10.7 1.9 21 13 12 255 20.5 0.2 21.1 20.3 07/24/2005 17:10:00 8 1.6 13.3 4.6 8.2 1.5 13 4.6 6.6 1.7 11.1 2.6 21 11 20 255 20 0 20.3 20 07/24/2005 17:20:00 7.4 1.5 11.1 3.4 7.5 1.5 11.5 3.8 6.1 1.6 10.7 1.9 23 13 23 255 20 0 20.3 19.7 07/24/2005 17:30:00 8.6 1.5 12.2 4.6 8.7 1.4 12.6 4.9 7.1 1.7 11.8 3 25 13 28 255 20.1 0 20.5 19.7 07/24/2005 17:40:00 7.9 1.4 11.1 4.6 8.1 1.3 11.1 4.6 7 1.6 11.1 2.6 25 12 32 255 19.8 0.1 20.5 19.4 07/24/2005 17:50:00 7 1.3 10.7 3.8 7.1 1.3 10.3 4.2 5.6 1.4 8.8 2.3 27 16 21 255 19.7 0 20.3 19.7 07/24/2005 18:00:00 9.1 1.5 12.6 4.6 9.1 1.5 12.6 4.2 7.6 1.7 11.8 3.4 34 13 29 255 19.7 0 20.3 19.7 07/24/2005 18:10:00 8.6 1.8 13.3 3.4 8.7 1.7 13 3.8 7.3 1.7 13 3 38 15 40 255 19.7 0 20.3 19.4 07/24/2005 18:20:00 7.3 1.5 10.7 3 7.4 1.5 10.7 4.2 6.3 1.5 9.9 2.6 39 14 28 255 19.5 0 20.3 19.4 07/24/2005 18:30:00 7.2 1.3 10.3 3.8 7.3 1.3 10.7 4.2 6.1 1.3 10.3 3.4 35 13 27 255 19.5 0 20 19.4 07/24/2005 18:40:00 6.7 1.4 11.1 3.4 6.9 1.3 11.1 3.8 5.6 1.3 10.3 2.3 30 16 19 255 19.5 0 19.4 19.4 07/24/2005 18:50:00 7.4 1.5 13.3 4.2 7.6 1.6 13.7 4.6 6 1.7 10.7 2.3 21 13 12 255 19.3 0 19.4 19.1 07/24/2005 19:00:00 8.8 1.5 13.7 5.3 8.9 1.5 13.7 5.7 7.3 1.6 11.8 3.4 20 10 17 255 19.2 0 19.4 19.1 07/24/2005 19:10:00 8.2 1.6 12.6 3 8.3 1.5 13 3.4 6.9 1.7 12.2 2.6 22 12 3 255 19 0 19.1 18.8 07/24/2005 19:20:00 8 1.2 11.1 4.6 8.1 1.2 11.5 4.9 6.8 1.5 9.9 3.4 21 11 25 255 18.9 0 19.1 18.8 07/24/2005 19:30:00 7.7 1.5 12.2 4.6 7.7 1.4 12.2 4.2 6.1 1.7 12.2 3 21 15 28 255 18.7 0 18.8 18.5 07/24/2005 19:40:00 7.4 1.3 10.7 3.4 7.5 1.3 11.1 3.8 5.8 1.5 9.9 2.3 19 14 9 255 18.5 0 18.8 18.5 07/24/2005 19:50:00 7.6 1.5 12.2 4.2 7.7 1.5 12.6 4.6 6.3 1.6 11.5 3 20 13 27 255 18.5 0 18.5 18.2 07/24/2005 20:00:00 7.4 1.2 11.5 3.8 7.5 1.2 11.5 4.2 5.7 1.4 10.3 2.3 21 12 37 255 18.4 0 18.5 18.2 07/24/2005 20:10:00 7.8 1.6 13 4.2 7.9 1.6 13.3 4.6 6.3 2 13 2.6 20 12 20 255 18.3 0 18.2 18 07/24/2005 20:20:00 8.1 1.6 12.2 4.6 8.2 1.5 12.2 4.6 6.7 1.7 10.7 2.3 22 13 18 255 18.3 0 18.5 18.2 07/24/2005 20:30:00 8.5 1.5 12.6 4.9 8.6 1.5 12.6 4.6 6.6 1.8 11.1 3 19 14 15 255 18.4 0 18.5 18.2 07/24/2005 20:40:00 7.7 1.7 12.6 3.8 7.8 1.6 12.6 3.8 6.4 1.7 11.8 2.6 24 14 20 255 18.2 0 18.5 18 07/24/2005 20:50:00 7.8 1.5 11.8 4.2 7.9 1.5 12.2 4.6 6.3 1.7 11.5 2.6 24 13 21 255 17.9 0 18.2 17.7 07/24/2005 21:00:00 7.6 1.3 11.1 4.2 7.6 1.3 11.5 4.6 6.2 1.4 10.3 3 25 14 35 255 17.8 0 18 17.7 07/24/2005 21:10:00 8.1 1.5 11.8 3.4 8.2 1.5 11.8 3.8 6.1 1.7 12.2 1.9 18 15 15 255 17.7 0 18 17.4 07/24/2005 21:20:00 9 1.6 13 4.2 9 1.6 13.3 4.2 6.8 1.8 12.2 2.3 19 13 11 255 17.5 0 18 17.4 07/24/2005 21:30:00 8.6 1.6 12.6 4.9 8.6 1.6 13 4.9 7 1.7 11.5 3.4 27 13 22 255 17.5 0 18 17.1 07/24/2005 21:40:00 9 1.6 13.3 4.9 8.9 1.6 13 4.9 7.3 1.7 11.8 3 27 13 34 255 17.3 0.1 17.7 17.1 07/24/2005 21:50:00 8.8 1.3 13 4.9 8.8 1.3 13 5.3 7.2 1.6 11.8 3 25 12 30 255 17.3 0 17.4 17.1 07/24/2005 22:00:00 8.3 1.4 12.2 4.9 8.2 1.4 11.8 5.3 6.4 1.6 10.7 1.9 19 13 17 255 17.3 0.1 17.7 17.1 07/24/2005 22:10:00 8.3 1.7 13.7 4.6 8.3 1.7 13.7 4.9 6.6 1.9 12.2 2.3 21 11 21 255 17.3 0.1 17.7 17.1 07/24/2005 22:20:00 7.8 1.7 12.2 4.6 7.8 1.7 12.2 4.2 6.1 1.8 11.5 2.3 22 12 27 255 17.1 0 17.4 16.8 07/24/2005 22:30:00 7.9 1.5 12.2 4.6 7.9 1.6 11.8 4.2 6.6 1.6 10.7 3 31 14 24 255 17.1 0 17.4 16.8 07/24/2005 22:40:00 7.4 1.2 10.7 3.4 7.4 1.2 10.3 3 6 1.2 9.9 2.6 37 15 30 255 17.1 0 17.4 16.8 07/24/2005 22:50:00 5.4 1.3 9.5 1.9 5.5 1.3 10.3 1.9 4.5 1.2 8.8 1.9 62 17 36 255 16.7 0.2 17.1 16.3 07/24/2005 23:00:00 5.2 1.1 7.6 2.6 5.3 1 7.6 2.6 4.1 1.2 7.2 1.1 83 17 90 255 15.9 0.1 16.8 15.7 07/24/2005 23:10:00 5.5 1.3 9.1 2.6 5.6 1.2 8.8 2.3 4.6 1.1 8 1.9 77 17 54 255 15.5 0 16.3 15.2 07/24/2005 23:20:00 6.2 1.2 9.5 3 6.3 1.2 9.5 3.4 5.1 1.2 8.8 2.3 65 14 61 255 15.2 0.1 15.7 15.2 07/24/2005 23:30:00 5.4 1 8.4 2.6 5.4 1 8.4 3 4.2 1.1 7.2 1.9 66 17 32 255 15.2 0.1 15.7 15.2 07/24/2005 23:40:00 6 1.2 9.5 2.3 6.1 1.2 9.5 2.6 5.1 1.3 8.8 2.3 65 15 54 255 15.2 0.1 15.7 15.2 07/24/2005 23:50:00 5.9 1.1 8.4 2.6 5.9 1.1 8.4 2.6 4.9 1.2 8.4 1.9 62 16 68 255 15.4 0 16 15.2 07/25/2005 00:00:00 6.9 1.3 10.7 3.8 6.9 1.5 11.1 3 5.8 1.5 9.5 1.9 54 16 40 255 15.7 0.1 16.3 15.5 07/25/2005 00:10:00 6.6 1.2 9.9 3.4 6.6 1.2 10.3 3.4 5.2 1.4 9.1 1.9 49 14 45 255 15.9 0 16.3 15.7 07/25/2005 00:20:00 6.9 1.1 10.7 3.8 6.9 1.2 11.1 4.2 5.7 1.3 8.8 1.9 52 14 51 255 16 0 16.6 16 07/25/2005 00:30:00 6.2 1.5 11.1 2.6 6.2 1.5 11.1 2.3 5.3 1.4 8.4 1.9 62 15 57 255 16.1 0 16.8 16 07/25/2005 00:40:00 6.2 1.3 9.5 2.6 6.3 1.3 9.5 1.9 5.1 1.3 9.5 1.5 62 15 72 255 16 0 16.6 16 07/25/2005 00:50:00 4.5 1 6.8 2.3 4.5 1 7.2 1.9 3.7 1 6.8 0.7 77 16 84 255 15.7 0 16.3 15.7 07/25/2005 01:00:00 5.9 1.2 9.5 3 6 1.2 9.9 3 5 1.2 8 2.3 68 17 64 255 15.7 0 16 15.5 07/25/2005 01:10:00 6.2 1.2 8.8 3.4 6.3 1.2 9.1 3.4 5.2 1.1 9.1 2.3 59 15 28 255 15.8 0.1 16.3 15.7 07/25/2005 01:20:00 6.5 1.1 9.5 3.4 6.4 1.1 9.5 2.6 5.2 1.3 8.8 1.9 56 15 67 255 15.9 0 16.3 15.7 07/25/2005 01:30:00 7.2 1.5 11.5 3 7.2 1.5 11.1 3.4 5.6 1.5 9.5 2.3 51 17 47 255 16.1 0.1 16.8 16 07/25/2005 01:40:00 6.5 1.5 10.3 3.4 6.5 1.5 10.7 3 5.5 1.6 10.3 1.9 58 16 44 255 16.3 0.2 16.8 16.3 07/25/2005 01:50:00 5.8 1.2 9.5 2.6 5.7 1.3 9.5 2.3 4.6 1.1 8 2.3 75 16 80 255 15.7 0.2 16.6 15.5 07/25/2005 02:00:00 5.5 1.3 9.1 2.6 5.5 1.3 8.8 3 4.5 1.3 9.1 1.9 76 17 58 255 15.5 0.1 16 15.2 07/25/2005 02:10:00 4.8 1.1 8 2.3 4.8 1.1 7.6 2.6 4 1.3 7.6 1.5 83 15 81 255 15.2 0.1 15.7 15.2 07/25/2005 02:20:00 5.2 0.8 6.8 3 5.1 0.9 7.2 2.6 3.9 1 6.1 1.9 82 13 80 255 14.9 0 15.7 14.9 07/25/2005 02:30:00 5 0.8 6.8 3.4 5 0.9 7.2 2.6 3.9 0.9 6.5 1.9 76 14 70 255 14.8 0 15.2 14.6 07/25/2005 02:40:00 4.9 0.9 7.2 2.6 5 0.8 6.8 2.6 3.8 0.8 5.7 1.9 79 13 83 255 14.9 0 15.5 14.9 07/25/2005 02:50:00 5 1 7.6 2.6 5.2 1 7.6 2.3 4 1 6.1 1.5 82 13 86 255 14.8 0 15.5 14.9 07/25/2005 03:00:00 5.5 1 8.4 3 5.6 1 8 3.4 4.4 1 7.2 1.9 82 13 84 255 15 0 15.2 14.9 07/25/2005 03:10:00 5 1.1 7.6 2.6 5 1 8 3 4.2 0.9 6.5 1.9 86 13 60 255 15 0 15.5 15.2 07/25/2005 03:20:00 4.7 1.1 7.6 2.3 4.8 1.1 7.6 2.3 4 1.1 6.5 1.5 81 15 78 255 15 0 15.5 15.2 07/25/2005 03:30:00 4.9 1.3 8.8 1.1 5 1.2 8.4 0.4 4 1.2 8 0.7 81 15 84 255 14.9 0 15.2 14.9 07/25/2005 03:40:00 5.2 1.3 8.8 1.5 5.3 1.3 8.8 1.5 4.3 1.3 7.2 1.9 83 17 108 255 14.9 0 15.2 14.9 07/25/2005 03:50:00 4.9 1 8 2.3 4.8 0.9 8 2.3 3.9 0.9 6.5 1.1 86 15 67 255 14.9 0 15.2 14.9 07/25/2005 04:00:00 4.8 1.2 8.4 2.3 4.9 1.1 8.4 2.3 4 1.1 8.8 1.5 92 17 84 255 15 0 15.2 14.9 07/25/2005 04:10:00 4.8 1 7.2 2.6 4.8 1 7.2 2.6 3.7 1.2 6.8 0.7 90 16 72 255 15 0 15.2 14.9 07/25/2005 04:20:00 5.3 1 8 2.6 5.4 1 7.6 2.6 4.5 1 7.6 2.3 95 16 87 255 14.9 0 15.5 14.9 07/25/2005 04:30:00 4.9 1.1 8 2.6 5 1.2 7.6 1.5 3.9 1.1 6.5 1.5 84 18 85 255 15 0 15.7 14.9 07/25/2005 04:40:00 5.4 1.3 9.1 2.3 5.5 1.3 9.1 2.6 4.4 1.3 7.6 1.1 79 18 69 255 15 0 15.7 15.2 07/25/2005 04:50:00 4.6 1.2 7.6 1.9 4.7 1.2 8.4 1.9 3.8 1.1 6.5 1.1 73 17 84 255 15.2 0 15.7 15.2 07/25/2005 05:00:00 4.6 1.1 8.8 2.3 4.6 1.1 8.8 2.3 3.8 1.1 6.5 1.9 67 18 73 255 15.1 0 15.7 15.2 07/25/2005 05:10:00 4.6 0.8 6.8 2.6 4.6 0.8 6.8 2.6 3.9 0.8 6.8 2.3 69 14 44 255 15.1 0 15.7 14.9 07/25/2005 05:20:00 4.4 0.7 6.1 2.3 4.4 0.7 6.1 2.3 3.6 0.8 5.3 1.5 76 13 64 255 14.8 0.1 15.5 14.6 07/25/2005 05:30:00 4.4 0.8 6.5 2.3 4.4 0.8 6.5 2.6 3.5 0.8 5.7 1.1 78 13 90 255 14.6 0.1 15.2 14.6 07/25/2005 05:40:00 4.7 0.8 6.5 2.6 4.6 0.8 6.5 2.3 3.7 0.9 6.1 1.5 81 12 78 255 14.7 0 15.2 14.6 07/25/2005 05:50:00 3.5 0.8 5.3 1.5 3.4 0.9 5.3 1.5 2.7 0.8 4.9 0.4 74 17 62 255 14.8 0 15.5 14.6 07/25/2005 06:00:00 2.9 0.8 4.9 0.4 2.8 0.8 4.6 0.4 2.2 0.8 4.2 0.4 70 19 86 255 15 0 15.7 14.9 07/25/2005 06:10:00 1.8 0.7 3.8 0.4 1.5 0.8 3.4 0.4 1.3 0.6 3.4 0.4 49 20 72 255 15 0 15.7 15.2 07/25/2005 06:20:00 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 36 19 42 255 15 0 15.7 14.9 07/25/2005 06:30:00 2.4 0.6 4.2 0.7 2.2 0.7 3.8 0.4 1.8 0.6 3.4 0.4 65 11 70 255 14.9 0 15.5 14.9 07/25/2005 06:40:00 2.1 0.5 3.4 1.1 1.9 0.5 3.4 0.7 1.6 0.4 3 0.4 55 10 73 255 15.1 0 15.5 14.9 07/25/2005 06:50:00 2.7 0.9 5.3 1.1 2.6 1 4.9 0.7 2 0.9 4.9 0.4 58 15 53 255 15.4 0 15.7 15.2 07/25/2005 07:00:00 1.9 0.6 3.4 0.4 1.6 0.7 3 0.4 1.3 0.5 2.6 0.4 50 20 32 255 15.6 0 16 15.5 07/25/2005 07:10:00 2.8 0.9 5.3 0.4 2.7 0.9 5.3 0.4 1.9 0.9 4.9 0.4 77 17 65 255 15.6 0 16 15.5 07/25/2005 07:20:00 3.6 1 6.5 1.1 3.5 1.1 6.5 0.7 2.5 1 5.7 0.4 81 17 81 255 15.9 0 16.3 15.7 07/25/2005 07:30:00 3.7 0.9 6.1 1.9 3.6 1 6.1 1.1 2.9 0.8 5.3 1.1 81 15 70 255 16.1 0 16.6 16.3 07/25/2005 07:40:00 4.3 1 6.8 1.5 4.2 1 6.5 1.5 3.3 1 6.1 1.1 81 17 69 255 16.1 0 16.8 16.3 07/25/2005 07:50:00 4.4 0.9 6.8 2.3 4.3 0.9 7.2 1.9 3.7 1 6.5 1.5 72 15 72 255 16.3 0.1 16.8 16.3 07/25/2005 08:00:00 4 1 6.8 0.4 4 1 6.5 0.4 3.2 0.9 5.7 1.1 75 15 85 255 16.3 0.1 16.8 16.3 07/25/2005 08:10:00 4.4 1.1 7.6 2.3 4.3 1 7.2 2.3 3.5 1 6.1 0.7 79 20 84 255 16.3 0.1 16.8 16.3 07/25/2005 08:20:00 4.6 1 6.8 1.9 4.5 1 6.5 2.3 3.6 1.1 6.1 0.4 81 15 79 255 16.4 0.1 16.8 16.3 07/25/2005 08:30:00 4.6 0.9 7.2 2.3 4.6 0.8 6.8 2.6 3.8 0.8 6.1 1.9 73 13 56 255 16.4 0 16.8 16.3 07/25/2005 08:40:00 4.9 0.9 7.6 2.6 4.8 0.9 7.6 2.6 3.8 1 6.5 1.1 68 14 59 255 16.5 0 16.8 16.6 07/25/2005 08:50:00 4.7 1 8 2.6 4.7 1.1 8.4 2.6 3.8 0.9 6.5 1.9 65 17 67 255 16.9 0 17.4 16.8 07/25/2005 09:00:00 4.6 1 6.8 2.6 4.6 1 6.8 2.3 3.9 1 6.5 1.9 53 16 39 255 17.1 0 17.4 16.8 07/25/2005 09:10:00 3.8 1 6.1 1.9 3.7 1 6.5 1.9 3.2 0.9 5.3 1.1 42 12 35 255 17.1 0 17.4 16.8 07/25/2005 09:20:00 3.2 0.7 4.9 1.5 3.1 0.8 4.9 1.5 2.7 0.8 4.9 0.7 40 14 38 255 17.2 0 17.4 17.1 07/25/2005 09:30:00 4.3 1 7.2 1.9 4.2 1 7.2 1.5 3.6 1 6.1 1.5 46 17 55 255 17.2 0 17.4 16.8 07/25/2005 09:40:00 4.5 1 7.2 1.5 4.5 1 7.6 0.7 3.6 1 6.8 1.5 53 16 51 255 17 0 17.1 16.8 07/25/2005 09:50:00 4.8 1.3 9.1 2.3 4.7 1.3 9.5 2.3 4.1 1.2 7.6 1.1 48 20 60 255 17.2 0 17.4 16.8 07/25/2005 10:00:00 4.5 1.3 8 1.5 4.4 1.3 8.8 1.1 3.8 1.3 8.8 0.4 47 23 19 255 17.8 0.2 18.2 17.4 07/25/2005 10:10:00 5.5 1.7 9.1 1.9 5.4 1.7 9.1 1.5 4.3 1.8 8.4 0.4 15 26 15 255 18.7 0.2 19.4 18 07/25/2005 10:20:00 4.5 1.4 10.3 1.5 4.3 1.5 10.3 1.1 3.1 1.3 8.4 0.4 3 23 21 255 19.2 0 19.4 19.1 07/25/2005 10:30:00 5.5 1.3 9.5 2.6 5.5 1.3 9.5 2.3 4.1 1.6 10.3 0.7 14 17 38 255 19.2 0 19.4 19.1 07/25/2005 10:40:00 5.5 1.6 10.3 1.1 5.6 1.6 9.9 1.1 4.5 1.4 10.7 1.1 17 18 8 255 19.3 0 19.4 19.1 07/25/2005 10:50:00 5.3 1.2 8 1.5 5.3 1.2 8 1.5 3.5 1.3 7.2 0.7 4 18 19 255 19.7 0.2 20.5 19.4 07/25/2005 11:00:00 5.5 1.1 8.8 2.6 5.4 1.2 8.8 1.9 4.1 1.2 8 0.7 12 22 28 255 20.3 0 20.8 20 07/25/2005 11:10:00 4.7 1.4 8.4 1.1 4.8 1.5 8.4 0.7 3.7 1.5 7.6 0.4 13 20 9 255 19.8 0 20.3 19.4 07/25/2005 11:20:00 4 1.3 8 1.5 3.9 1.4 8 1.5 2.8 1.3 6.5 0.4 2 22 329 255 20.3 0.1 20.8 20 07/25/2005 11:30:00 5.6 1.1 8.8 2.6 5.7 1.2 8.8 2.6 4.2 1.5 9.1 1.1 3 18 24 255 20.3 0.1 20.8 20 07/25/2005 11:40:00 3.8 1 6.1 1.5 3.7 1.1 6.5 1.1 2.5 1 6.1 0.4 3 24 16 255 20.2 0.1 20.8 20 07/25/2005 11:50:00 5 1.1 7.6 2.6 5.2 1.1 7.6 3 4.1 1.2 7.2 1.9 51 19 43 255 20.4 0 21.1 20.3 07/25/2005 12:00:00 6 1.7 10.7 2.3 6.2 1.7 11.1 2.3 5.1 1.7 9.5 0.7 58 15 66 255 20.7 0.3 21.7 20.3 07/25/2005 12:10:00 5.7 1.7 9.1 1.5 5.8 1.7 9.1 1.9 4.9 1.6 9.1 1.1 55 22 27 255 21.6 0 22.3 21.4 07/25/2005 12:20:00 7.4 1.3 10.7 3 7.5 1.3 10.7 4.2 6 1.5 9.5 2.6 24 16 9 255 20.9 0.4 21.7 20.3 07/25/2005 12:30:00 8.1 1.4 11.8 4.6 8.2 1.4 11.8 4.6 6.8 1.5 9.9 3 28 15 17 255 19.8 0.3 20.5 19.4 07/25/2005 12:40:00 7.6 1.3 10.7 3.4 7.6 1.3 11.1 3.4 6.6 1.5 10.3 3 37 14 35 255 19.2 0.1 19.7 18.8 07/25/2005 12:50:00 6.6 1.8 11.1 2.6 6.6 1.9 11.1 2.3 5.6 1.7 10.3 1.9 44 20 15 255 19 0 19.4 18.8 07/25/2005 13:00:00 6.6 1.3 9.9 3.4 6.6 1.3 9.9 3.4 5.6 1.5 9.9 2.3 32 17 20 255 19.1 0 19.7 18.8 07/25/2005 13:10:00 7 1.7 11.8 3.8 7 1.7 11.8 3.8 6 1.5 10.3 2.6 33 14 21 255 19.1 0 19.4 19.1 07/25/2005 13:20:00 8.1 1.2 10.7 4.9 8.1 1.2 11.1 4.6 6.6 1.3 9.9 3.8 32 12 25 255 19 0 19.1 18.5 07/25/2005 13:30:00 6 1.7 9.9 2.6 6.1 1.6 9.9 2.6 5.2 1.6 9.9 1.9 42 15 40 255 18.5 0.1 18.8 18.2 07/25/2005 13:40:00 6 1.3 9.5 2.6 6 1.3 9.5 3 4.9 1.3 8.8 2.3 48 14 59 255 18 0.1 18.2 17.7 07/25/2005 13:50:00 5.3 1.2 8 2.6 5.3 1.2 8.4 2.3 4.6 1.2 7.6 1.5 40 15 25 255 17.7 0 18 17.4 07/25/2005 14:00:00 4.5 1.2 8 2.3 4.6 1.2 7.6 1.9 3.9 1.2 6.8 1.1 31 18 25 255 17.4 0 17.7 17.1 07/25/2005 14:10:00 6.6 1.3 10.7 3.4 6.6 1.3 10.3 3 5.4 1.5 9.1 2.3 22 13 16 255 17.4 0 17.7 17.1 07/25/2005 14:20:00 8.1 1.3 11.8 4.6 8 1.3 11.8 4.6 6.6 1.6 12.2 2.6 26 12 8 255 17.3 0 17.4 17.1 07/25/2005 14:30:00 9.1 1.7 13 4.9 9 1.7 13.7 4.6 7.1 1.9 13.3 2.6 20 13 20 255 17.4 0.1 17.7 17.1 07/25/2005 14:40:00 7.8 1.2 11.5 4.2 7.7 1.2 11.8 4.2 6.3 1.5 10.3 2.6 25 13 19 255 17.8 0 18 17.4 07/25/2005 14:50:00 6 1.1 8.8 3 5.9 1.2 8.8 2.6 5 1.2 8.8 2.3 30 13 31 255 17.8 0 18.2 17.7 07/25/2005 15:00:00 5.9 1.1 9.1 2.6 5.9 1.2 9.1 2.3 4.9 1.2 8 2.3 46 13 53 255 18.2 0.1 18.8 17.7 07/25/2005 15:10:00 5.9 1.2 8.8 2.6 5.9 1.3 9.1 2.6 5 1.4 8.8 1.9 52 18 68 255 18.7 0 19.1 18.5 07/25/2005 15:20:00 5.9 1.4 9.5 2.3 5.9 1.5 8.8 1.9 4.9 1.3 8.4 1.5 44 15 39 255 18.6 0.1 19.1 18.2 07/25/2005 15:30:00 6.6 1.3 9.9 2.6 6.6 1.4 10.3 2.3 5.6 1.3 9.5 2.3 38 15 16 255 18.5 0 18.8 18.2 07/25/2005 15:40:00 8.4 1.3 11.8 4.9 8.4 1.4 11.8 4.6 6.9 1.5 11.1 2.6 28 13 38 255 18.9 0 19.1 18.5 07/25/2005 15:50:00 7.8 1.1 10.7 4.9 7.8 1.2 10.7 4.6 6.2 1.7 10.7 1.9 25 15 28 255 19.2 0 19.4 19.1 07/25/2005 16:00:00 7.6 1.4 11.5 4.6 7.5 1.5 11.5 4.2 6.1 1.7 11.1 2.6 23 11 21 255 19.2 0 19.4 18.8 07/25/2005 16:10:00 6.8 1.1 9.9 4.2 6.7 1.1 9.5 4.6 5.5 1.3 8.8 2.6 32 13 38 255 18.9 0.1 19.1 18.5 07/25/2005 16:20:00 6.8 1.3 10.3 3.8 6.8 1.3 10.7 3.8 5.5 1.4 9.5 2.6 41 17 47 255 18.3 0 18.5 18 07/25/2005 16:30:00 7.8 1.9 13.3 4.2 7.7 1.9 13.3 4.2 6.6 1.7 11.8 2.6 37 15 42 255 17.8 0 18.2 17.4 07/25/2005 16:40:00 7 1.7 10.7 3.4 7 1.7 10.7 2.6 6 1.7 11.1 1.9 41 16 12 255 17.5 0 17.7 17.1 07/25/2005 16:50:00 6.7 1.3 9.9 3.4 6.6 1.3 10.3 3.4 5.7 1.5 9.5 2.3 46 17 35 255 17.3 0.1 17.7 17.1 07/25/2005 17:00:00 7.7 1.8 13 2.6 7.7 1.9 12.6 2.3 6.2 1.7 11.5 2.6 38 13 31 255 17.3 0 17.7 17.1 07/25/2005 17:10:00 7.5 1.5 11.1 3.4 7.5 1.5 11.1 4.6 6.3 1.4 9.9 2.6 37 15 35 255 17.5 0 18 17.1 07/25/2005 17:20:00 8.1 1.4 11.1 4.2 8.1 1.4 11.5 3.8 6.7 1.6 10.7 3 41 17 50 255 18 0.1 18.2 17.7 07/25/2005 17:30:00 6.9 1.7 12.2 2.6 6.9 1.7 12.2 2.3 5.7 1.7 10.3 1.5 39 16 70 255 18.2 0 18.5 18 07/25/2005 17:40:00 7.8 1.7 12.2 3.8 7.7 1.7 12.2 3.4 6.6 2 11.1 1.9 38 13 35 255 18.5 0.1 19.1 18.2 07/25/2005 17:50:00 8.3 1.8 12.6 3.8 8.2 1.8 13 3.8 6.8 1.7 11.8 3.4 39 13 38 255 18.6 0.2 19.1 18.2 07/25/2005 18:00:00 8.6 1.3 13 5.3 8.5 1.4 13.3 4.9 7.1 1.7 11.5 2.3 42 15 48 255 18.2 0.1 18.5 17.7 07/25/2005 18:10:00 7.3 1.7 11.8 3 7.3 1.7 11.8 2.6 6.1 1.7 10.7 3 43 17 25 255 17.8 0 18 17.4 07/25/2005 18:20:00 6.9 1.5 11.5 2.6 6.9 1.5 11.5 3 5.7 1.5 11.1 2.6 47 17 47 255 18.2 0 18.5 18 07/25/2005 18:30:00 6 1.6 10.7 1.5 6.1 1.6 10.7 1.5 5 1.7 8.8 1.1 44 17 18 255 18.5 0 18.8 18.2 07/25/2005 18:40:00 6.2 1.5 9.9 3 6.1 1.5 9.5 2.6 4.9 1.6 9.5 1.1 20 18 355 255 18.6 0 18.8 18.2 07/25/2005 18:50:00 7.1 2.1 11.8 2.6 7.1 2.2 11.8 2.3 5.4 2.1 10.7 1.1 13 16 20 255 18.2 0.1 18.5 17.7 07/25/2005 19:00:00 7.1 1.6 11.1 3.8 7.1 1.7 10.7 3.8 5.5 1.7 9.9 1.5 16 13 11 255 17.7 0 18.2 17.4 07/25/2005 19:10:00 5.8 1.5 9.1 1.5 5.7 1.5 9.1 1.1 4.4 1.7 8.4 0.7 8 17 10 255 17.5 0.1 17.7 17.1 07/25/2005 19:20:00 5.3 1.1 8 2.6 5.2 1.2 8.4 2.3 4 1.2 7.6 1.5 12 16 18 255 17.3 0 17.7 17.1 07/25/2005 19:30:00 6.7 1.6 9.9 2.3 6.7 1.7 10.3 2.3 4.9 1.7 9.9 1.5 10 14 4 255 17.2 0 17.7 16.8 07/25/2005 19:40:00 8.4 1.9 13 4.6 8.4 2 13 4.6 6.6 2.4 12.2 1.5 14 13 19 255 17.1 0 17.4 16.8 07/25/2005 19:50:00 8.4 1.8 12.6 2.6 8.4 1.8 12.6 2.6 6.7 2 11.1 1.1 18 12 3 255 16.8 0 17.4 16.8 07/25/2005 20:00:00 8.8 1.3 12.2 5.3 8.8 1.3 12.2 5.3 7.4 1.5 12.2 4.2 28 12 12 255 16.8 0 17.1 16.8 07/25/2005 20:10:00 6.4 1.3 9.9 3.8 6.3 1.3 9.5 3.4 5.1 1.5 9.1 1.9 26 14 27 255 16.9 0 17.1 16.8 07/25/2005 20:20:00 6.2 1.1 10.3 3.4 6.2 1.2 10.7 3 4.9 1.2 8.8 1.5 28 14 34 255 16.7 0 17.1 16.6 07/25/2005 20:30:00 5.9 1.2 8.8 3.4 5.8 1.2 8.8 3 5 1.3 9.1 2.3 34 14 46 255 16.7 0 17.1 16.6 07/25/2005 20:40:00 6.2 1 9.1 4.2 6.2 1 9.1 3.8 5.1 1.1 8 2.3 35 13 4 255 16.7 0 17.1 16.6 07/25/2005 20:50:00 5.5 0.8 7.6 3 5.4 0.9 7.6 3 4.5 1 7.2 1.9 30 14 21 255 16.5 0.2 16.8 16.3 07/25/2005 21:00:00 6.7 1.2 9.5 3 6.6 1.3 9.9 2.6 5.4 1.4 8.4 1.9 23 12 20 255 16.4 0.1 16.8 16.3 07/25/2005 21:10:00 7.8 1.3 11.5 4.6 7.8 1.3 11.5 4.6 5.8 1.6 10.3 1.9 14 13 13 255 16.3 0.1 16.8 16.3 07/25/2005 21:20:00 7.1 1.4 10.3 2.6 7 1.5 10.7 3 5.2 1.7 9.1 1.1 10 14 0 255 16.1 0 16.8 16 07/25/2005 21:30:00 5.5 1.2 9.9 2.6 5.4 1.3 9.5 2.6 3.9 1.5 8.8 1.1 12 22 47 255 15.8 0 16.3 15.7 07/25/2005 21:40:00 5.3 1.2 9.9 3 5.2 1.2 9.9 2.6 4.1 1.2 8 1.9 27 15 22 255 15.6 0 16.3 15.5 07/25/2005 21:50:00 4.7 0.9 7.2 1.9 4.6 1 6.8 1.5 3.8 0.9 6.5 1.1 23 14 13 255 15.3 0.2 16 15.2 07/25/2005 22:00:00 4 1 6.5 1.9 3.8 1 6.5 1.5 2.5 1.2 5.3 0.4 9 14 10 255 14.8 0.2 15.5 14.6 07/25/2005 22:10:00 4.2 0.8 6.5 2.3 4.1 0.9 6.5 1.5 2.5 1 4.9 0.4 4 14 3 255 14.2 0.2 14.9 13.8 07/25/2005 22:20:00 2.5 1 5.3 0.4 2.2 1.2 4.9 0.4 1.4 0.9 4.6 0.4 351 15 9 255 13.9 0 14.1 13.8 07/25/2005 22:30:00 1.7 0.5 3.4 0.7 1.3 0.7 3 0.4 1 0.5 2.3 0.4 295 24 252 255 13.8 0 14.4 13.5 07/25/2005 22:40:00 3 0.6 4.9 1.9 2.8 0.6 4.9 1.5 2 0.7 4.6 0.7 238 12 234 255 13.6 0 14.4 13.5 07/25/2005 22:50:00 2.8 0.6 4.6 1.1 2.5 0.7 4.6 0.7 1.8 0.6 3.8 0.4 238 12 233 255 13.9 0 14.4 13.5 07/25/2005 23:00:00 2.6 0.7 4.2 0.7 2.4 0.8 4.2 0.4 1.4 0.7 3 0.4 246 15 235 255 14 0 14.6 13.8 07/25/2005 23:10:00 1.3 0.7 3.4 0.4 0.9 0.7 3 0.4 0.7 0.4 2.3 0.4 296 47 280 255 14.5 0.1 15.2 14.4 07/25/2005 23:20:00 1.2 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 352 19 10 255 14.7 0 15.2 14.6 07/25/2005 23:30:00 1 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 315 21 295 255 14.4 0 15.2 14.4 07/25/2005 23:40:00 0.8 0.4 2.3 0.4 0.4 0.3 1.9 0.4 0.4 0.1 0.7 0.4 345 13 3 255 14.1 0.1 14.6 13.8 07/25/2005 23:50:00 1 0.3 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 301 30 271 255 13.8 0 14.4 13.5 07/26/2005 00:00:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 12 8 20 255 13.5 0 13.8 13.3 07/26/2005 00:10:00 1 0.3 1.9 0.4 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 311 26 322 255 13.2 0 13.5 13 07/26/2005 00:20:00 1.1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 292 0 292 255 12.9 0 13.3 12.7 07/26/2005 00:30:00 1.5 0.2 1.9 0.7 1.1 0.3 1.9 0.4 1 0.4 1.5 0.4 289 3 292 255 12.6 0 12.7 12.5 07/26/2005 00:40:00 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 288 3 287 255 12.4 0 12.7 12.2 07/26/2005 00:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 289 255 12.3 0 12.5 12.2 07/26/2005 01:00:00 0.8 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 289 0 289 255 12.1 0 12.2 11.9 07/26/2005 01:10:00 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 333 47 25 255 12 0 12.2 11.9 07/26/2005 01:20:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 44 6 30 255 11.7 0 11.9 11.4 07/26/2005 01:30:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 29 255 11.3 0 11.7 11.1 07/26/2005 01:40:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 31 9 77 255 11.1 0 11.4 11.1 07/26/2005 01:50:00 1.6 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.5 0.3 1.5 0.4 84 24 100 255 11 0 11.1 10.9 07/26/2005 02:00:00 1.7 0.3 2.6 1.1 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 33 4 35 255 11 0 11.1 10.9 07/26/2005 02:10:00 2.1 0.4 3 1.1 1.8 0.4 2.6 0.7 0.9 0.5 2.3 0.4 29 8 30 255 10.9 0 11.1 10.9 07/26/2005 02:20:00 1.8 0.3 2.6 1.1 1.4 0.4 2.6 0.4 0.9 0.5 2.3 0.4 40 10 30 255 10.9 0 11.1 10.9 07/26/2005 02:30:00 1.7 0.3 2.6 0.7 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 60 11 38 255 10.7 0 10.9 10.6 07/26/2005 02:40:00 0.9 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 71 9 57 255 10.7 0 10.9 10.6 07/26/2005 02:50:00 1.6 0.6 3 0.4 1.3 0.7 2.6 0.4 0.9 0.5 1.9 0.4 70 10 68 255 10.6 0 10.6 10.6 07/26/2005 03:00:00 2.2 0.6 3.4 0.7 2 0.7 3.4 0.4 1.4 0.5 3 0.4 83 13 88 255 10.6 0 10.9 10.6 07/26/2005 03:10:00 1 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.5 0.4 1.9 0.4 124 26 60 255 10.5 0 10.6 10.6 07/26/2005 03:20:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 78 24 64 255 10.3 0 10.6 10.1 07/26/2005 03:30:00 1.8 0.3 2.6 1.1 1.6 0.4 2.6 0.7 1.2 0.4 2.3 0.4 75 10 56 255 9.8 0.1 10.3 9.6 07/26/2005 03:40:00 2.4 0.3 3.8 1.5 2.2 0.4 3.8 1.1 1.7 0.4 2.6 0.7 71 8 59 255 9.6 0 9.6 9.6 07/26/2005 03:50:00 2.1 0.6 3.8 1.1 1.8 0.7 3.4 0.4 1.4 0.7 3.4 0.4 109 32 150 255 9.3 0.1 9.6 9 07/26/2005 04:00:00 2.4 0.5 3.8 1.1 2.3 0.6 3.4 0.7 1.9 0.7 3.4 0.4 160 11 167 255 9.2 0 9.3 9 07/26/2005 04:10:00 2.4 0.4 3 1.5 2.2 0.4 3.4 1.1 1.5 0.4 2.3 0.4 127 10 129 255 9.1 0.1 9.3 9 07/26/2005 04:20:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 116 7 107 255 8.9 0 9 8.8 07/26/2005 04:30:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 129 26 138 255 8.7 0 8.8 8.5 07/26/2005 04:40:00 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 105 19 148 255 8.4 0 8.8 8.3 07/26/2005 04:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 146 26 127 255 8.4 0 8.5 8.3 07/26/2005 05:00:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 159 3 169 255 8.6 0 8.8 8.5 07/26/2005 05:10:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 1.1 0.4 2.3 0.4 133 15 124 255 8.7 0 8.8 8.5 07/26/2005 05:20:00 1.7 0.4 2.6 0.4 1.5 0.4 2.6 0.4 0.6 0.3 1.5 0.4 111 14 104 255 8.9 0.1 9.3 8.8 07/26/2005 05:30:00 1.5 0.4 2.3 0.7 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 129 17 104 255 9.4 0.1 9.8 9 07/26/2005 05:40:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 119 17 110 255 10.1 0.1 10.3 9.8 07/26/2005 05:50:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.3 1.5 0.4 127 12 95 255 10.6 0.2 11.1 10.3 07/26/2005 06:00:00 2.5 0.6 3.8 0.7 2.3 0.6 3.8 0.4 2 0.6 3.4 0.4 106 12 102 255 12 0.6 13 11.1 07/26/2005 06:10:00 2.4 0.8 4.2 0.4 2.1 0.8 3.8 0.4 1.8 0.7 3.8 0.4 99 18 72 255 13.4 0.3 13.8 12.7 07/26/2005 06:20:00 2.5 0.5 3.8 1.1 2.3 0.6 3.4 0.7 2 0.5 3 0.4 95 11 84 255 14.2 0 14.4 13.8 07/26/2005 06:30:00 2.4 0.5 3.8 1.1 2.2 0.5 3.8 1.1 2 0.5 3.4 0.4 98 11 102 255 14.5 0 15.2 14.4 07/26/2005 06:40:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.7 0.7 3 0.4 93 13 113 255 14.5 0 14.9 14.4 07/26/2005 06:50:00 2.5 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.2 0.4 3.4 1.1 98 11 102 255 14.4 0 14.6 14.4 07/26/2005 07:00:00 2.2 0.6 3.4 0.4 1.9 0.8 3.8 0.4 1.6 0.8 3.4 0.4 106 17 95 255 14.6 0 15.2 14.4 07/26/2005 07:10:00 2.3 0.6 3.4 0.7 2 0.6 3 0.4 2 0.6 3.4 0.4 92 10 90 255 15 0 15.2 14.9 07/26/2005 07:20:00 1.9 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.7 0.6 3.4 0.4 90 21 105 255 15.2 0 16 15.2 07/26/2005 07:30:00 2.3 0.8 3.8 0.4 2 0.9 3.8 0.4 1.8 0.8 3.4 0.4 99 21 112 255 15.5 0 16 15.5 07/26/2005 07:40:00 1.8 0.5 3.4 0.4 1.5 0.6 3.4 0.4 1.4 0.5 2.6 0.4 77 20 83 255 15.6 0 16.3 15.5 07/26/2005 07:50:00 1.6 0.6 3.4 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 51 21 63 255 15.7 0.1 16.3 15.7 07/26/2005 08:00:00 1.9 0.4 3 0.7 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 59 19 44 255 15.9 0.1 16.3 15.7 07/26/2005 08:10:00 2 0.7 3.4 0.4 1.7 0.9 3.4 0.4 1.6 0.7 3.4 0.4 83 18 101 255 16.6 0.1 16.8 16.3 07/26/2005 08:20:00 1.7 0.6 3.4 0.4 1.3 0.7 3 0.4 1.3 0.6 3 0.4 73 19 54 255 17.2 0.3 18 16.8 07/26/2005 08:30:00 2.3 0.7 3.8 0.7 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 89 21 68 255 18.2 0.2 18.5 17.7 07/26/2005 08:40:00 2.7 0.8 4.6 0.4 2.6 0.8 4.2 0.4 2.4 0.8 4.2 0.4 99 13 86 255 18.5 0.1 18.8 18.2 07/26/2005 08:50:00 2.6 0.9 4.6 0.4 2.5 0.9 4.9 0.4 2.3 1 4.2 0.4 87 26 104 255 19.1 0.2 20 18.8 07/26/2005 09:00:00 2.7 0.7 4.6 1.1 2.6 0.7 4.6 0.7 2.4 0.8 4.2 0.7 62 17 68 255 19.6 0 20 19.4 07/26/2005 09:10:00 2.5 0.7 4.2 0.7 2.3 0.8 4.2 0.4 2.3 0.7 3.8 0.7 45 30 40 255 19.7 0.1 20.3 19.4 07/26/2005 09:20:00 2.5 1.1 5.3 0.4 2.3 1.2 4.6 0.4 1.8 1.2 4.6 0.4 11 22 32 255 20.3 0 20.8 20 07/26/2005 09:30:00 1.9 0.9 3.4 0.4 1.8 1 3.4 0.4 1.6 0.8 3.8 0.4 57 36 55 255 20.4 0 21.1 20.3 07/26/2005 09:40:00 1.8 1.1 4.2 0.4 1.6 1.1 4.2 0.4 1.5 1 3.8 0.4 58 43 3 255 20.6 0.2 21.1 20.3 07/26/2005 09:50:00 2.3 0.7 3.8 0.4 2 0.7 3.8 0.4 1.9 0.8 3.4 0.4 9 32 337 255 21 0.1 21.4 20.5 07/26/2005 10:00:00 2.5 0.6 4.2 0.4 2.3 0.6 4.2 0.7 1.7 0.8 3.8 0.4 358 27 349 255 21.1 0 21.4 20.8 07/26/2005 10:10:00 2.5 0.7 4.2 1.1 2.4 0.7 4.2 0.7 2.1 0.8 4.2 0.4 25 21 29 255 21.1 0 21.4 20.8 07/26/2005 10:20:00 1.9 0.6 3.8 0.7 1.8 0.6 3.4 0.7 1.4 0.7 3.4 0.4 21 26 14 255 20.7 0.1 21.1 20.5 07/26/2005 10:30:00 2.3 0.8 3.8 0.4 2.1 0.8 3.4 0.4 1.6 0.9 3.8 0.4 359 45 21 255 20.1 0.2 20.5 19.4 07/26/2005 10:40:00 2.3 0.6 4.2 0.4 2.1 0.6 3.8 0.4 1.7 0.8 3.8 0.4 328 17 337 255 19.3 0 20 19.1 07/26/2005 10:50:00 2.4 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.9 0.7 3.8 0.4 358 36 47 255 20.5 0.3 21.1 19.7 07/26/2005 11:00:00 2.4 0.7 3.8 0.4 2.2 0.7 3.8 0.4 1.9 0.7 3.8 0.4 331 66 327 255 19.9 0.3 20.5 19.4 07/26/2005 11:10:00 2 0.8 3.4 0.4 1.7 0.6 3.4 0.4 1.5 0.7 3.4 0.4 329 22 339 255 20.4 0.7 21.4 19.4 07/26/2005 11:20:00 1.4 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.7 2.6 0.4 20 66 357 255 21.7 0.1 22 21.4 07/26/2005 11:30:00 2.7 0.9 4.9 0.7 2.6 1 4.9 0.4 2 0.9 4.6 0.4 8 30 10 255 22.5 0.2 23.2 22 07/26/2005 11:40:00 1.8 0.7 4.2 0.4 1.7 0.6 4.6 0.4 1.4 0.7 3.8 0.4 19 49 7 255 22.9 0.1 23.5 22.6 07/26/2005 11:50:00 2.3 0.9 4.6 0.4 2.3 0.8 4.6 0.4 1.8 0.8 4.2 0.4 38 32 18 255 22.4 0.6 23.2 21.1 07/26/2005 12:00:00 1.9 0.8 3.8 0.4 1.8 0.8 3.4 0.4 1.4 0.8 3.8 0.4 16 36 341 255 21.2 0.4 22.3 20.8 07/26/2005 12:10:00 2.7 0.8 5.3 1.1 2.6 0.9 4.9 1.1 2.2 0.8 4.6 0.4 14 30 21 255 22.9 0.2 23.5 22.3 07/26/2005 12:20:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.4 0.7 3.8 0.4 24 58 84 255 23.4 0 23.8 23.2 07/26/2005 12:30:00 3.9 1.1 6.5 1.1 3.9 1.1 6.5 1.5 3.1 1 6.1 0.7 17 17 2 255 23.3 0.2 23.8 23.2 07/26/2005 12:40:00 3.4 1.1 7.2 1.1 3.3 1.1 6.8 1.1 2.5 1.2 5.3 0.4 12 27 18 255 23.5 0 23.8 23.5 07/26/2005 12:50:00 3.3 0.7 4.9 1.5 3.1 0.8 4.9 1.5 2.5 1 4.9 0.4 351 27 343 255 22.6 0.3 23.5 22 07/26/2005 13:00:00 3.5 1 5.7 1.1 3.4 1.1 5.7 1.1 2.6 1.2 4.9 0.4 6 22 31 255 22 0.1 22.3 21.7 07/26/2005 13:10:00 2.4 0.9 4.2 0.4 2.3 0.9 4.2 0.4 1.5 0.8 3.4 0.4 0 28 6 255 21.9 0 22 21.7 07/26/2005 13:20:00 2.9 0.6 4.2 1.5 2.9 0.6 4.6 1.5 2.3 0.8 3.8 0.4 20 15 24 255 21.9 0.1 22 21.7 07/26/2005 13:30:00 2.5 0.7 4.6 0.7 2.5 0.7 4.2 0.7 1.8 0.8 3.4 0.4 33 28 9 255 21.7 0 22 21.7 07/26/2005 13:40:00 2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.6 0.8 3.8 0.4 6 45 1 255 22.4 0 22.9 22 07/26/2005 13:50:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1 0.7 3.4 0.4 31 51 57 255 22.2 0 22.6 22 07/26/2005 14:00:00 1.2 0.7 3.4 0.4 1.2 0.7 3.4 0.4 1 0.6 3 0.4 35 30 37 255 22.1 0.1 22.6 21.7 07/26/2005 14:10:00 1.7 0.6 3.4 0.4 1.7 0.7 3.8 0.4 1.3 0.7 3.4 0.4 57 23 44 255 22.5 0 22.9 22.3 07/26/2005 14:20:00 1 0.7 3 0.4 1 0.7 3 0.4 1.1 0.7 2.6 0.4 35 58 38 255 22.6 0.4 23.2 22 07/26/2005 14:30:00 2.1 0.7 4.2 0.4 2.1 0.7 4.2 0.4 1.6 0.8 3.8 0.4 72 21 52 255 22.7 0.5 23.8 22 07/26/2005 14:40:00 2.4 0.7 4.2 0.4 2.4 0.8 4.2 0.4 2.1 0.8 3.8 0.4 68 30 32 255 23.5 0.1 23.8 23.5 07/26/2005 14:50:00 2.2 0.7 4.2 0.4 2.3 0.7 4.2 0.7 1.8 0.6 3.8 0.4 76 35 21 255 23.1 0.2 23.5 22.9 07/26/2005 15:00:00 3.5 1 6.1 1.1 3.5 1 6.1 1.5 2.6 1 5.7 0.4 31 24 15 255 23.9 0.4 24.7 23.2 07/26/2005 15:10:00 3.7 1 6.8 1.5 3.7 1.1 6.5 1.5 3 1.3 6.1 0.4 27 26 30 255 23.3 0.8 24.7 22.3 07/26/2005 15:20:00 3.4 1.2 6.8 1.5 3.4 1.3 7.2 0.7 2.5 1.4 6.8 0.4 6 27 47 255 21.9 0.2 22.3 21.4 07/26/2005 15:30:00 6.5 0.7 8.4 4.6 6.5 0.7 8.4 4.6 5.8 0.9 8 3.4 27 10 18 255 21.6 0 22 21.4 07/26/2005 15:40:00 5.7 1 8.4 3.4 5.7 1 8.4 3.4 4.7 1.1 7.6 1.5 22 12 12 255 21.6 0 22 21.1 07/26/2005 15:50:00 4.8 1.1 7.6 2.3 4.7 1.1 7.6 2.3 3.6 1.2 6.8 1.1 18 15 2 255 21.7 0.2 22.6 21.4 07/26/2005 16:00:00 4.7 0.9 6.8 2.6 4.7 0.9 7.2 2.6 3.7 1 6.8 1.1 20 12 28 255 22.5 0.5 23.8 22 07/26/2005 16:10:00 4.4 1 6.1 1.5 4.4 1 6.5 1.9 3.5 1.3 6.5 0.7 36 15 48 255 23.2 0.5 23.8 22 07/26/2005 16:20:00 3.8 1 6.5 1.1 3.8 1 6.5 1.5 3.2 1 6.1 1.1 41 12 35 255 21 0.4 22 20.5 07/26/2005 16:30:00 2.8 0.8 4.6 0.7 2.9 0.8 4.6 0.7 2.3 0.9 4.6 0.4 48 16 63 255 21.9 0.4 22.6 21.1 07/26/2005 16:40:00 2.4 1.1 4.9 0.4 2.5 1.1 4.6 0.4 1.8 1 4.2 0.4 33 29 3 255 23 0.1 23.8 22.6 07/26/2005 16:50:00 4.2 0.7 6.1 2.3 4.2 0.8 6.5 2.3 3.6 0.7 5.3 1.9 43 17 31 255 22.4 0.6 23.8 21.4 07/26/2005 17:00:00 4.6 0.6 6.1 3 4.7 0.7 6.5 2.6 3.6 0.9 5.7 1.5 32 14 14 255 21.2 0.1 21.7 20.8 07/26/2005 17:10:00 3.9 1 6.1 1.5 3.9 1 6.1 1.9 3.2 1.1 5.7 0.7 41 14 51 255 20.5 0 21.4 20.5 07/26/2005 17:20:00 2.9 0.6 4.6 0.7 2.9 0.6 4.2 1.1 2.6 0.8 3.8 0.7 50 15 70 255 20.2 0 20.5 20 07/26/2005 17:30:00 2.3 0.6 3.8 0.7 2.4 0.6 3.8 1.1 1.7 0.8 3.8 0.4 55 17 60 255 20.2 0 20.8 20 07/26/2005 17:40:00 2.7 0.5 3.8 1.5 2.7 0.6 3.8 1.1 2.2 0.7 3.8 0.7 56 15 52 255 20.1 0.1 20.8 19.7 07/26/2005 17:50:00 2.5 0.6 4.2 0.7 2.6 0.6 3.8 0.7 1.9 0.7 3.4 0.4 60 15 48 255 20.3 0.1 20.8 20 07/26/2005 18:00:00 2.7 0.5 3.8 1.1 2.7 0.5 3.4 1.1 2.2 0.6 3.4 0.4 63 11 65 255 20 0.1 20.5 19.7 07/26/2005 18:10:00 2.2 0.6 3.4 0.4 2.3 0.6 3.8 0.4 1.6 0.7 3.4 0.4 59 15 47 255 19.8 0.1 20.5 19.7 07/26/2005 18:20:00 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.1 1.9 0.5 3 0.4 43 16 29 255 19.7 0 20.3 19.7 07/26/2005 18:30:00 2.6 0.5 3.8 1.1 2.6 0.5 3.8 0.7 2.2 0.7 3.4 0.4 39 14 17 255 20.2 0.1 20.8 20 07/26/2005 18:40:00 3.6 0.6 4.6 2.3 3.6 0.5 4.6 1.9 3.1 0.7 4.9 1.1 27 11 30 255 20.4 0 21.1 20.3 07/26/2005 18:50:00 3.5 0.7 4.9 1.9 3.5 0.7 4.9 1.9 2.6 0.9 4.6 0.4 8 12 24 255 20.5 0 20.8 20.3 07/26/2005 19:00:00 3.7 0.6 5.3 2.3 3.7 0.6 5.3 1.9 2.5 0.7 4.6 0.7 10 12 10 255 20 0 20.8 19.7 07/26/2005 19:10:00 2.5 0.6 3.8 0.7 2.4 0.7 3.8 0.7 1.1 0.8 3 0.4 350 15 0 255 19.4 0 20.3 19.1 07/26/2005 19:20:00 3.6 0.7 5.7 1.9 3.6 0.7 5.3 1.9 2.3 0.8 4.2 0.4 11 13 37 255 18.7 0.2 19.4 18.2 07/26/2005 19:30:00 3.6 0.6 5.3 1.9 3.6 0.6 5.3 2.3 2 0.7 3.8 0.4 6 12 23 255 18 0 18.5 17.7 07/26/2005 19:40:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 0.7 0.6 2.6 0.4 13 10 10 255 17.7 0 17.7 17.4 07/26/2005 19:50:00 1.7 0.4 3 0.7 1.6 0.5 2.6 0.7 0.8 0.5 1.9 0.4 356 17 14 255 17.7 0 17.7 17.4 07/26/2005 20:00:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 0.7 0.4 2.3 0.4 327 9 312 255 17.7 0 17.7 17.4 07/26/2005 20:10:00 1.7 0.7 3.8 0.4 1.7 0.7 4.2 0.4 0.8 0.7 3.4 0.4 305 27 269 255 17.5 0 17.7 17.4 07/26/2005 20:20:00 1.9 0.7 4.2 0.7 1.9 0.7 4.2 0.7 1.1 0.7 3 0.4 292 28 253 255 17.5 0 17.7 17.4 07/26/2005 20:30:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 0.9 0.7 3 0.4 298 16 297 255 17.3 0 17.7 17.1 07/26/2005 20:40:00 2 0.9 4.2 0.4 1.9 0.9 3.8 0.4 1.2 0.8 3.4 0.4 287 17 282 255 17.1 0 17.1 16.8 07/26/2005 20:50:00 1.3 0.7 2.6 0.4 1.3 0.7 2.6 0.4 0.8 0.5 2.3 0.4 276 13 281 255 17.1 0 17.1 16.8 07/26/2005 21:00:00 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.7 0.5 2.3 0.4 292 21 284 255 16.8 0 17.1 16.6 07/26/2005 21:10:00 1.3 0.7 3.4 0.4 1.3 0.7 3.4 0.4 0.7 0.6 3 0.4 277 12 282 255 16.4 0.1 16.8 16.3 07/26/2005 21:20:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 0.6 0.4 1.9 0.4 302 13 296 255 15.9 0.1 16.6 15.7 07/26/2005 21:30:00 1.3 0.3 1.9 0.4 1.2 0.4 1.9 0.4 0.4 0.2 1.5 0.4 307 12 328 255 15.4 0.2 16 15.2 07/26/2005 21:40:00 1.3 0.4 2.6 0.4 1.3 0.4 2.6 0.4 0.4 0.2 1.5 0.4 296 14 284 255 14.9 0 15.5 14.6 07/26/2005 21:50:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 293 11 289 255 14.6 0.1 15.2 14.4 07/26/2005 22:00:00 0.9 0.2 1.5 0.4 0.7 0.2 1.5 0.4 0.4 0 0.4 0.4 305 0 305 255 14.2 0.2 14.9 13.8 07/26/2005 22:10:00 0.8 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 305 0 305 255 13.8 0 14.4 13.5 07/26/2005 22:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 317 2 305 255 13.5 0 14.1 13.3 07/26/2005 22:30:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 13 9 317 255 13.1 0.1 13.8 12.7 07/26/2005 22:40:00 0.6 0.3 1.1 0.4 0.5 0.3 1.1 0.4 0.6 0.2 1.1 0.4 44 28 60 255 12.9 0 13.3 12.7 07/26/2005 22:50:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.2 1.1 0.4 77 5 82 255 12.8 0 13.3 12.7 07/26/2005 23:00:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.7 0.4 92 2 94 255 12.5 0.1 12.7 12.5 07/26/2005 23:10:00 0.8 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 75 17 56 255 12.4 0 12.7 12.2 07/26/2005 23:20:00 1 0.3 1.5 0.4 1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 56 0 56 255 12.3 0 12.7 11.9 07/26/2005 23:30:00 1.1 0.2 1.5 0.7 1.1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 56 0 56 255 11.9 0.1 12.5 11.9 07/26/2005 23:40:00 0.8 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 60 6 56 255 11.8 0 12.5 11.7 07/26/2005 23:50:00 1 0.2 1.5 0.7 1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 68 0 68 255 11.7 0 12.2 11.7 07/27/2005 00:00:00 1 0.4 1.5 0.4 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 68 0 68 255 11.5 0 11.9 11.4 07/27/2005 00:10:00 1.2 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.4 0.2 1.5 0.4 69 3 64 255 11.3 0 11.7 11.1 07/27/2005 00:20:00 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.4 0.2 1.1 0.4 58 7 49 255 10.9 0 11.4 10.9 07/27/2005 00:30:00 1.5 0.3 2.3 0.7 1.5 0.4 2.3 0.7 0.6 0.3 1.5 0.4 69 14 53 255 10.7 0 10.9 10.6 07/27/2005 00:40:00 1.9 0.3 2.6 1.1 1.9 0.4 2.6 0.7 0.9 0.4 1.9 0.4 92 11 80 255 10.5 0 10.9 10.6 07/27/2005 00:50:00 2.4 0.3 3.4 1.5 2.4 0.4 3.4 1.5 1.5 0.4 2.3 0.4 70 7 62 255 10.6 0 10.6 10.6 07/27/2005 01:00:00 2.2 0.4 3.4 0.7 2.2 0.4 3.8 1.1 1 0.5 2.6 0.4 78 8 81 255 10.3 0.1 10.6 10.1 07/27/2005 01:10:00 2.3 0.5 3.4 1.1 2.3 0.5 3.8 1.1 1.1 0.6 3 0.4 73 12 80 255 9.9 0 10.1 9.8 07/27/2005 01:20:00 2 0.4 3.4 0.7 1.9 0.5 3.8 1.1 0.9 0.4 2.3 0.4 72 15 34 255 9.6 0 9.8 9.6 07/27/2005 01:30:00 2 0.4 3 0.7 2.1 0.4 3.4 1.1 1.1 0.4 2.3 0.4 72 12 68 255 9.5 0 9.6 9.6 07/27/2005 01:40:00 2.3 0.6 3.8 0.7 2.4 0.7 4.2 0.7 1.5 0.7 3.4 0.4 62 16 68 255 9.4 0 9.6 9.3 07/27/2005 01:50:00 2.1 0.5 3.8 1.1 2.2 0.5 4.2 1.1 1.3 0.5 2.6 0.4 66 9 44 255 9.4 0 9.6 9.3 07/27/2005 02:00:00 2.5 0.5 3.8 1.1 2.4 0.5 3.4 1.1 1.3 0.5 2.6 0.4 91 19 92 255 9.6 0 9.6 9.6 07/27/2005 02:10:00 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.4 0.9 0.5 2.3 0.4 112 18 94 255 9.5 0 9.6 9.3 07/27/2005 02:20:00 2.6 0.8 4.9 0.7 2.5 0.8 4.6 0.7 1.2 0.7 3 0.4 111 16 87 255 9.6 0 9.8 9.6 07/27/2005 02:30:00 3.1 0.9 4.6 0.4 3.1 0.9 4.9 0.7 2 0.8 3.8 0.4 111 18 88 255 10.3 0.3 10.9 9.8 07/27/2005 02:40:00 1.8 0.5 3 0.4 1.8 0.5 3 0.4 1.1 0.5 2.6 0.4 135 18 132 255 10.9 0 11.1 10.6 07/27/2005 02:50:00 2.4 0.5 3.8 1.1 2.4 0.5 3.8 0.7 1.2 0.5 2.3 0.4 113 11 105 255 11.1 0 11.1 11.1 07/27/2005 03:00:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.2 0.5 2.6 0.4 114 15 105 255 10.9 0 11.1 10.9 07/27/2005 03:10:00 1.9 0.5 3.4 0.4 1.9 0.5 3.4 0.4 1.1 0.5 2.3 0.4 129 15 121 255 10.8 0 11.1 10.9 07/27/2005 03:20:00 1.9 0.5 3 0.7 1.9 0.5 3 0.7 1.3 0.5 2.3 0.4 124 14 113 255 11 0 11.4 10.9 07/27/2005 03:30:00 1.2 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.5 0.2 1.5 0.4 134 12 108 255 11.5 0 11.7 11.4 07/27/2005 03:40:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 129 12 133 255 11.7 0 11.7 11.7 07/27/2005 03:50:00 1.5 0.4 2.3 0.4 1.4 0.4 2.6 0.4 0.8 0.4 1.9 0.4 153 13 169 255 11.7 0 11.7 11.7 07/27/2005 04:00:00 1.4 0.5 2.3 0.4 1.4 0.5 2.6 0.4 0.7 0.4 1.9 0.4 136 14 144 255 11.7 0 11.9 11.7 07/27/2005 04:10:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.9 0.4 99 35 142 255 11.9 0 11.9 11.7 07/27/2005 04:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 51 255 11.7 0 11.9 11.7 07/27/2005 04:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 145 33 159 255 11.7 0 11.9 11.7 07/27/2005 04:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 135 0 135 255 11.7 0 11.7 11.7 07/27/2005 04:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 0 135 255 11.7 0 11.9 11.7 07/27/2005 05:00:00 0.8 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 129 10 113 255 11.9 0 12.2 11.7 07/27/2005 05:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 166 23 121 255 12.2 0 12.2 11.9 07/27/2005 05:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 164 20 127 255 12.3 0 12.5 12.2 07/27/2005 05:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 136 13 165 255 12.4 0 12.5 12.2 07/27/2005 05:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 149 15 164 255 12.5 0 12.5 12.5 07/27/2005 05:50:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.9 0.4 100 53 176 255 12.5 0 12.7 12.5 07/27/2005 06:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 116 18 102 255 12.7 0 12.7 12.5 07/27/2005 06:10:00 1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.7 0.3 1.5 0.4 137 14 150 255 12.8 0 12.7 12.7 07/27/2005 06:20:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.7 0.4 2.3 0.4 119 15 130 255 12.8 0 12.7 12.7 07/27/2005 06:30:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 106 27 131 255 12.8 0 13.3 12.7 07/27/2005 06:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 109 13 106 255 12.9 0 13.5 12.7 07/27/2005 06:50:00 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 108 6 109 255 13.1 0.1 13.5 12.7 07/27/2005 07:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 128 13 109 255 13.1 0 13.5 13 07/27/2005 07:10:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.9 0.4 124 15 121 255 13.2 0 13.5 13 07/27/2005 07:20:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 86 12 103 255 13.3 0 13.8 13.3 07/27/2005 07:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 86 21 52 255 13.5 0 14.1 13.3 07/27/2005 07:40:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 98 21 121 255 13.7 0 14.1 13.5 07/27/2005 07:50:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 86 9 86 255 13.9 0 14.6 13.8 07/27/2005 08:00:00 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 109 11 102 255 14 0.1 14.6 13.8 07/27/2005 08:10:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 86 1 90 255 14.2 0.1 14.6 14.1 07/27/2005 08:20:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 60 19 54 255 14.4 0 14.9 14.4 07/27/2005 08:30:00 1.9 0.5 3.4 0.4 1.8 0.5 3.4 0.4 1.4 0.6 2.6 0.4 55 17 54 255 14.5 0 15.2 14.4 07/27/2005 08:40:00 1.9 0.7 3 0.4 1.8 0.7 3 0.4 1.7 0.7 3 0.4 41 14 26 255 14.5 0 15.2 14.6 07/27/2005 08:50:00 1.9 0.4 2.6 0.7 1.8 0.5 2.6 0.7 1.5 0.5 3 0.4 42 12 55 255 14.5 0 14.6 14.6 07/27/2005 09:00:00 3.4 0.6 4.6 1.9 3.4 0.6 4.6 1.9 2.8 0.7 4.6 0.7 18 8 19 255 14.5 0 14.6 14.6 07/27/2005 09:10:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.3 2.8 0.7 4.6 0.7 33 12 48 255 14.3 0.1 15.2 13.8 07/27/2005 09:20:00 3.9 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.3 0.7 4.9 1.1 35 12 37 255 13.5 0.2 14.1 13 07/27/2005 09:30:00 3 0.5 4.2 1.5 3 0.5 4.6 1.1 2.5 0.6 4.2 0.7 46 13 53 255 12.9 0.1 13.3 12.7 07/27/2005 09:40:00 2.5 0.6 4.2 0.7 2.5 0.6 4.2 0.7 1.7 0.7 3.4 0.4 57 16 58 255 12.8 0 13.3 12.7 07/27/2005 09:50:00 1.8 0.5 3 0.4 1.8 0.5 3 0.4 1.3 0.6 2.6 0.4 58 20 64 255 12.9 0.1 13.3 12.7 07/27/2005 10:00:00 1.9 0.6 3.8 0.7 1.9 0.7 3.4 0.7 1.5 0.7 3 0.4 48 20 33 255 13.2 0 13.5 13 07/27/2005 10:10:00 2.4 0.6 3.8 1.1 2.4 0.6 3.8 1.1 1.8 0.6 3.4 0.4 47 13 38 255 13.3 0 13.5 13.3 07/27/2005 10:20:00 2.9 0.6 3.8 1.1 2.8 0.6 4.2 1.1 2 0.7 3.4 0.4 34 17 48 255 13.6 0 13.8 13.3 07/27/2005 10:30:00 3.1 1 5.3 0.7 3.1 1 5.3 0.7 2.4 1 4.9 0.4 42 16 47 255 13.9 0 14.4 13.8 07/27/2005 10:40:00 2.5 0.7 4.2 1.1 2.5 0.7 4.2 1.1 1.9 0.7 4.6 0.4 56 17 42 255 14.2 0 14.6 13.8 07/27/2005 10:50:00 2.3 0.6 4.2 0.7 2.3 0.7 4.2 0.7 1.7 0.7 3.4 0.4 53 20 30 255 14.6 0.1 15.2 14.4 07/27/2005 11:00:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 1.1 2 0.8 3.8 0.4 48 22 17 255 15.3 0.2 16 15.2 07/27/2005 11:10:00 2.8 0.8 4.9 1.1 2.8 0.8 5.3 0.7 2.2 0.8 4.2 0.4 67 23 40 255 16.1 0.2 16.8 15.7 07/27/2005 11:20:00 4 1.1 6.5 0.7 4 1.2 6.8 0.4 3.5 1.2 5.7 0.4 66 21 65 255 16.4 0 16.8 16.3 07/27/2005 11:30:00 4.5 0.9 6.8 2.3 4.5 0.9 7.2 2.3 3.6 0.9 6.1 1.1 43 22 43 255 16.4 0.1 16.8 16.3 07/27/2005 11:40:00 4.7 1.1 7.6 1.9 4.7 1.1 8 2.6 3.9 1.2 7.6 1.9 36 17 34 255 16.5 0 16.8 16.3 07/27/2005 11:50:00 5.2 0.8 7.2 3.4 5.1 0.8 7.6 3 4.3 1 6.5 1.9 33 13 19 255 16.2 0.1 16.8 16 07/27/2005 12:00:00 3.4 0.9 6.1 1.1 3.4 0.9 6.1 1.5 2.7 1 5.7 0.4 58 19 43 255 15.9 0 16.3 15.7 07/27/2005 12:10:00 2.9 0.7 4.6 1.5 2.9 0.7 4.6 1.1 2.4 0.7 4.6 0.7 76 17 32 255 15.7 0.1 16.3 15.7 07/27/2005 12:20:00 2.9 0.6 4.9 1.1 3 0.6 4.6 1.5 2.1 0.8 4.6 0.4 79 21 79 255 15.7 0 16.3 15.7 07/27/2005 12:30:00 3.5 0.8 5.7 1.5 3.5 0.9 5.3 1.9 2.7 0.8 4.6 0.7 86 13 68 255 15.3 0.2 16 15.2 07/27/2005 12:40:00 3.6 0.6 4.9 1.9 3.6 0.6 4.9 1.5 2.9 0.7 4.6 1.1 107 13 110 255 15.1 0.1 15.7 15.2 07/27/2005 12:50:00 3.1 0.8 4.9 1.1 3.1 0.8 4.6 1.1 2.4 0.7 4.2 0.4 113 13 109 255 15.5 0.1 16.3 15.2 07/27/2005 13:00:00 2.3 0.8 4.6 0.7 2.2 0.7 4.6 0.7 1.6 0.7 4.2 0.4 122 21 142 255 16.2 0.3 17.1 15.7 07/27/2005 13:10:00 2.9 0.7 4.9 1.1 2.8 0.8 4.6 1.1 2.4 0.8 4.2 0.4 120 22 93 255 17.4 0.2 17.7 16.8 07/27/2005 13:20:00 2.4 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2 0.9 3.8 0.4 110 19 102 255 19 0.7 20.3 17.7 07/27/2005 13:30:00 2.4 0.7 3.8 0.7 2.4 0.7 4.2 0.7 2.1 0.8 3.8 0.4 84 24 77 255 20.5 0.2 21.1 20 07/27/2005 13:40:00 1.8 0.8 3.4 0.4 1.7 0.9 3.8 0.4 1.3 0.8 3.4 0.4 39 39 115 255 21.2 0.1 21.7 20.8 07/27/2005 13:50:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.7 0.7 3.8 0.4 63 32 67 255 21.6 0 22.3 21.4 07/27/2005 14:00:00 3.6 2.1 8.8 0.7 3.6 2.1 8.8 0.7 2.9 1.9 7.6 0.4 71 36 49 255 22.3 0.1 22.9 21.7 07/27/2005 14:10:00 5.9 1.5 8.8 2.3 5.9 1.5 9.1 2.3 4.9 1.6 8.4 1.1 42 20 28 255 22.4 0.4 23.2 22 07/27/2005 14:20:00 6.1 1.6 9.9 2.3 6.1 1.7 9.5 1.9 4.7 1.6 8.4 1.1 16 21 347 255 23.9 0.4 24.7 23.2 07/27/2005 14:30:00 6.8 1.6 9.9 2.6 6.7 1.7 9.9 2.6 5.1 1.8 9.5 1.5 14 21 349 255 24.7 0 25 24.4 07/27/2005 14:40:00 5.5 1.8 9.9 0.7 5.4 1.8 9.9 1.1 4.1 1.7 8 0.4 6 23 70 255 25.3 0.2 25.6 24.7 07/27/2005 14:50:00 6.5 1.5 9.9 2.6 6.4 1.5 9.9 2.3 4.6 1.8 9.9 0.7 12 22 18 255 24.6 0.4 25.6 23.8 07/27/2005 15:00:00 7 1.6 10.7 3.4 6.9 1.7 10.7 2.6 5.6 1.9 9.9 0.7 15 20 29 255 23.8 0 23.8 23.5 07/27/2005 15:10:00 5.7 1.3 8.8 2.3 5.6 1.3 8.8 1.9 4.2 1.4 8 0.4 17 23 15 255 23.3 0.4 24.4 22.9 07/27/2005 15:20:00 6.1 1.4 9.1 2.6 6.1 1.5 9.5 2.6 4.5 1.7 9.1 0.7 10 21 12 255 24.9 0.3 25.6 24.4 07/27/2005 15:30:00 5.8 1.2 9.5 2.6 5.8 1.2 9.1 2.6 4.1 1.6 8 0.7 9 17 355 255 25.1 0 25.3 25 07/27/2005 15:40:00 5.5 1.2 9.1 1.9 5.5 1.3 9.1 1.5 4.3 1.4 8.8 1.1 26 17 55 255 24.9 0 25.3 24.7 07/27/2005 15:50:00 5.1 1 7.6 2.6 5.1 1 7.6 2.3 4.2 1.2 7.2 0.4 34 17 25 255 24.8 0.2 25.3 24.7 07/27/2005 16:00:00 4.4 1.1 7.6 1.9 4.5 1.1 7.2 1.9 3.6 1.2 6.5 0.7 29 19 350 255 24.7 0 25 24.7 07/27/2005 16:10:00 5.3 1.1 8 2.6 5.2 1.1 7.6 2.3 4.4 1 7.2 1.9 44 15 49 255 24.2 0.2 24.7 23.8 07/27/2005 16:20:00 6.1 1 8.8 3.4 6.1 1 9.1 3.4 4.9 1.2 7.6 1.9 22 13 16 255 23.8 0 23.8 23.5 07/27/2005 16:30:00 5.8 1 8 3 5.8 1 7.6 3 4.5 1.4 7.2 1.1 14 14 4 255 23.6 0 23.8 23.5 07/27/2005 16:40:00 6.2 1.5 9.1 1.9 6.1 1.5 9.5 2.3 4.8 1.5 8 1.1 19 13 19 255 23.5 0 23.8 23.2 07/27/2005 16:50:00 5.6 1 8 3 5.6 1.1 8.4 3 4.6 1.1 7.6 1.9 21 11 24 255 22.2 0.4 23.2 21.7 07/27/2005 17:00:00 5.6 1 8 2.6 5.6 1.1 8 2.6 4.5 1.3 7.6 1.1 19 15 16 255 21.8 0.1 22.3 21.4 07/27/2005 17:10:00 5.6 0.8 7.6 2.3 5.6 0.8 8 2.3 4.2 1.2 7.2 1.1 20 18 10 255 22.3 0 22.6 22.3 07/27/2005 17:20:00 4.8 1.2 7.2 1.9 4.8 1.2 7.6 1.9 3.8 1.5 6.8 0.4 18 16 9 255 22.4 0 22.6 22 07/27/2005 17:30:00 6.5 0.9 10.3 3.8 6.5 0.9 10.3 3.8 5.1 1.2 8.4 2.3 19 10 23 255 21.6 0 22.3 21.4 07/27/2005 17:40:00 6.4 1 9.5 3.4 6.5 1 9.5 3.8 5.2 1.3 8.4 1.9 21 12 22 255 21.5 0 22 21.4 07/27/2005 17:50:00 6 1.1 10.7 3.8 6 1.1 10.3 3.4 4.4 1.3 8 1.5 19 13 54 255 21.3 0 21.4 21.1 07/27/2005 18:00:00 6 1 8.4 3.4 6 1 8.4 2.3 4.6 1.3 8.4 1.5 20 16 17 255 21.3 0 21.4 21.1 07/27/2005 18:10:00 7.2 1.6 12.2 3.8 7.3 1.6 11.8 2.6 5.3 1.7 9.9 1.5 14 12 14 255 20.8 0.3 21.4 20.3 07/27/2005 18:20:00 6.8 1.2 9.5 3 6.8 1.2 9.9 3.4 5.8 1.5 9.1 1.9 24 15 24 255 20.6 0.1 21.1 20.5 07/27/2005 18:30:00 6.8 1.3 10.3 2.6 6.8 1.3 10.7 2.6 5.5 1.7 10.7 1.5 20 12 21 255 20.5 0 21.1 20.5 07/27/2005 18:40:00 7.2 1.2 11.1 4.6 7.1 1.2 11.1 4.2 5.5 1.7 10.7 1.9 19 15 32 255 20.7 0.1 21.1 20.5 07/27/2005 18:50:00 7.4 1.3 11.1 4.2 7.4 1.3 10.7 3.8 6.1 1.6 10.7 2.6 23 14 15 255 20.6 0.2 21.1 20 07/27/2005 19:00:00 7.6 1.4 10.7 3 7.6 1.5 11.1 3.4 5.9 1.5 9.5 2.3 21 13 28 255 19.7 0.2 20.5 19.4 07/27/2005 19:10:00 7.5 1.4 11.1 3.4 7.4 1.4 11.5 3 6.1 1.7 9.9 1.9 24 14 13 255 19.1 0.1 19.4 18.8 07/27/2005 19:20:00 6.7 1.3 10.3 3 6.7 1.4 10.3 3 5.2 1.5 9.5 1.5 19 14 18 255 19 0.1 19.4 18.8 07/27/2005 19:30:00 6.6 1.3 9.9 3.4 6.6 1.3 10.3 3 5.3 1.5 8.8 1.5 27 16 0 255 19 0 19.4 18.5 07/27/2005 19:40:00 6.6 1 9.5 3.8 6.6 1 9.5 3.8 5.4 1.2 8 2.6 22 12 20 255 18.5 0.1 18.8 18.2 07/27/2005 19:50:00 6.4 1.2 9.5 3 6.4 1.3 9.1 3.4 5.2 1.5 9.1 1.5 22 13 39 255 18.3 0 18.5 18 07/27/2005 20:00:00 5.9 1.3 9.1 3 5.8 1.2 9.1 3 4.7 1.3 8.4 1.1 25 13 6 255 18 0 18.2 18 07/27/2005 20:10:00 5.8 1.3 9.5 2.6 5.8 1.3 9.5 2.6 4.4 1.4 9.1 1.5 25 17 24 255 17.9 0 18 17.7 07/27/2005 20:20:00 6.4 1.4 9.9 1.9 6.4 1.4 9.1 1.9 5.1 1.6 8.8 0.7 22 15 25 255 17.7 0 17.7 17.4 07/27/2005 20:30:00 7 1.3 9.9 3 6.9 1.3 10.3 2.6 5.2 1.7 8.8 1.1 16 15 355 255 17.5 0 17.7 17.4 07/27/2005 20:40:00 6.3 1.3 9.1 3.4 6.3 1.4 9.1 2.6 4.8 1.5 8.4 1.1 17 12 9 255 17.2 0 17.4 16.8 07/27/2005 20:50:00 6.5 1.7 10.3 2.6 6.5 1.7 10.7 2.6 5.1 1.7 9.5 1.1 15 13 14 255 17.1 0 17.1 16.8 07/27/2005 21:00:00 7 1.4 10.7 4.2 7 1.3 10.3 4.2 5.2 1.5 8.8 1.5 16 14 6 255 17.1 0 17.4 16.8 07/27/2005 21:10:00 6.4 1.2 9.9 3 6.3 1.2 9.9 3 4.7 1.5 8.4 1.1 17 11 25 255 16.8 0.1 17.1 16.8 07/27/2005 21:20:00 6.7 1.2 9.5 3.4 6.7 1.2 9.9 3.4 4.9 1.4 8.8 2.3 15 12 4 255 16.8 0 17.1 16.6 07/27/2005 21:30:00 6.3 1.3 8.8 2.3 6.2 1.4 9.1 2.3 4.6 1.7 8.8 0.7 14 12 14 255 16.6 0.1 17.1 16.3 07/27/2005 21:40:00 5.9 1.3 10.3 3 6 1.3 10.7 2.6 4.5 1.5 8.8 1.9 13 13 22 255 16.2 0.1 16.8 16 07/27/2005 21:50:00 5.1 1.3 8.8 2.6 5.1 1.3 8.4 2.6 3.5 1.3 7.2 1.1 7 13 14 255 15.7 0.2 16.3 15.2 07/27/2005 22:00:00 3.9 0.9 6.1 1.9 3.9 0.9 6.1 1.9 2.3 1 4.9 0.4 5 15 16 255 15.2 0.2 15.7 14.9 07/27/2005 22:10:00 4.7 1 8.8 2.3 4.7 1 8.4 1.9 3.4 1 6.5 0.7 14 12 10 255 15 0 15.7 14.9 07/27/2005 22:20:00 5.1 1 7.6 2.6 5.1 1 7.6 2.6 3.5 1.2 6.1 1.1 11 12 17 255 14.8 0.1 15.5 14.6 07/27/2005 22:30:00 4.4 0.8 6.8 2.3 4.5 0.8 6.5 2.6 3.3 1 6.1 0.7 10 11 19 255 14.8 0 15.2 14.6 07/27/2005 22:40:00 4.5 1.2 7.2 1.5 4.4 1.2 7.2 1.1 2.6 1.2 6.1 0.7 12 18 8 255 14.9 0 15.5 14.9 07/27/2005 22:50:00 3.7 1 6.8 1.1 3.6 1.1 6.5 1.1 2.2 1.1 5.3 0.4 3 15 4 255 14.7 0.1 15.2 14.6 07/27/2005 23:00:00 2.4 0.7 4.6 1.1 2.4 0.8 4.9 0.7 1.2 0.7 3 0.4 12 17 12 255 14.7 0.2 15.2 14.6 07/27/2005 23:10:00 3.8 0.7 5.7 1.9 3.8 0.7 5.7 2.3 2.7 0.8 4.9 0.7 22 15 38 255 14.8 0.1 15.5 14.6 07/27/2005 23:20:00 3.2 0.8 5.7 1.5 3.2 0.8 5.7 1.5 2 1 4.6 0.4 11 15 33 255 15 0.1 15.5 14.9 07/27/2005 23:30:00 4.4 1 6.8 2.3 4.3 1 6.8 2.6 3.4 1.2 6.5 0.4 19 12 25 255 15.2 0.1 15.7 15.2 07/27/2005 23:40:00 3.6 0.8 5.3 1.9 3.5 0.9 5.3 1.5 2.1 1 5.3 0.4 7 17 12 255 15.4 0.2 16.3 15.2 07/27/2005 23:50:00 2.9 0.7 4.6 1.1 2.8 0.7 4.9 1.1 1.6 0.9 4.9 0.4 13 13 11 255 15 0.1 15.7 14.9 07/28/2005 00:00:00 3 1.1 6.1 0.7 2.9 1.2 6.1 0.7 2 1.2 5.3 0.4 10 15 7 255 14.9 0 15.5 14.9 07/28/2005 00:10:00 1.8 0.6 3.4 0.4 1.7 0.7 3.4 0.4 0.9 0.7 3.4 0.4 18 26 53 255 14.6 0 15.2 14.4 07/28/2005 00:20:00 3.1 0.7 4.9 1.1 3 0.7 4.6 1.1 2.2 0.8 4.2 0.4 28 17 37 255 14.6 0 15.2 14.6 07/28/2005 00:30:00 4.3 0.7 5.7 1.5 4.2 0.7 5.7 1.5 3.1 1 4.9 0.7 15 11 34 255 14.5 0 14.9 14.6 07/28/2005 00:40:00 3.1 0.8 5.7 1.5 3 0.8 6.1 1.1 1.5 0.8 4.2 0.4 7 16 16 255 14.4 0 14.6 14.1 07/28/2005 00:50:00 2 0.7 3.4 0.4 1.9 0.7 3.8 0.4 1.1 0.6 3 0.4 21 20 15 255 13.9 0 14.6 13.5 07/28/2005 01:00:00 1.9 0.5 3 0.7 1.9 0.5 3 0.7 1.1 0.5 2.3 0.4 78 9 80 255 13.1 0.2 13.5 12.7 07/28/2005 01:10:00 2.6 0.4 4.2 1.1 2.6 0.5 4.2 1.9 1.7 0.6 3.8 0.4 80 11 69 255 12.7 0 13 12.5 07/28/2005 01:20:00 2.5 0.5 4.2 1.5 2.4 0.5 4.2 1.1 1.7 0.5 3.4 0.4 97 22 60 255 12.5 0 12.7 12.5 07/28/2005 01:30:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.8 0.5 3.4 0.4 114 14 126 255 12.7 0.2 13.3 12.5 07/28/2005 01:40:00 1.9 0.5 3 0.4 1.9 0.6 3 0.4 1.2 0.5 2.3 0.4 109 15 100 255 12.7 0 13 12.5 07/28/2005 01:50:00 2.1 0.3 3 1.5 2 0.4 3 1.1 1.3 0.4 2.3 0.4 112 11 131 255 12.6 0 13 12.5 07/28/2005 02:00:00 1.8 0.4 2.6 0.4 1.7 0.5 2.6 0.4 1.1 0.5 2.6 0.4 98 13 113 255 12.5 0 12.7 12.5 07/28/2005 02:10:00 1.4 0.3 2.3 0.4 1.2 0.4 1.9 0.4 0.7 0.4 1.5 0.4 97 11 87 255 12.4 0 12.7 12.2 07/28/2005 02:20:00 1.2 0.6 2.6 0.4 1.1 0.7 3 0.4 0.7 0.5 2.3 0.4 90 18 64 255 12.3 0 12.7 12.2 07/28/2005 02:30:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 0.7 0.4 1.9 0.4 66 9 44 255 12.4 0.1 12.7 12.5 07/28/2005 02:40:00 1.4 0.2 2.3 0.7 1.4 0.3 2.3 0.7 0.8 0.4 1.9 0.4 72 8 59 255 12.5 0 12.7 12.5 07/28/2005 02:50:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 81 0 80 255 12.4 0.1 12.7 12.2 07/28/2005 03:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 68 14 81 255 12.5 0 12.7 12.5 07/28/2005 03:10:00 1 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 101 22 108 255 12.5 0 12.5 12.5 07/28/2005 03:20:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.7 0.3 1.5 0.4 100 9 103 255 12.4 0 12.5 12.2 07/28/2005 03:30:00 1.9 0.5 3 0.7 1.9 0.5 2.6 0.4 1 0.5 2.3 0.4 110 11 113 255 12.4 0 12.7 12.2 07/28/2005 03:40:00 1.8 0.5 2.6 0.4 1.7 0.5 2.6 0.4 0.8 0.4 1.9 0.4 109 11 106 255 12.4 0 12.5 12.2 07/28/2005 03:50:00 1.7 0.3 2.3 0.4 1.7 0.4 2.6 0.4 0.6 0.3 1.5 0.4 101 9 99 255 12.1 0 12.5 11.9 07/28/2005 04:00:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.4 0.5 0.3 1.9 0.4 105 10 95 255 11.7 0 11.9 11.7 07/28/2005 04:10:00 2.2 0.4 3 1.1 2.3 0.4 3 0.7 1.1 0.5 2.6 0.4 101 8 103 255 11.6 0 11.7 11.7 07/28/2005 04:20:00 2.6 0.4 3.4 1.9 2.7 0.3 3.4 1.5 1.4 0.5 2.3 0.4 89 8 76 255 11.5 0 11.7 11.4 07/28/2005 04:30:00 1.6 1.1 3.8 0.4 1.6 1.2 3.8 0.4 0.9 0.6 2.6 0.4 34 61 84 255 11.5 0 11.7 11.4 07/28/2005 04:40:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 40 39 56 255 11.4 0 11.7 11.4 07/28/2005 04:50:00 0.7 0.5 1.9 0.4 0.6 0.5 1.9 0.4 0.4 0 0.7 0.4 63 4 70 255 11.4 0 11.4 11.4 07/28/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 255 255 11.4 0 11.7 11.4 07/28/2005 05:10:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 114 38 140 255 11.5 0 11.9 11.4 07/28/2005 05:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.2 1.1 0.4 158 4 160 255 11.7 0 11.9 11.7 07/28/2005 05:30:00 1.3 0.2 1.9 0.7 1.1 0.3 1.9 0.4 1.2 0.4 1.9 0.4 154 4 160 255 11.7 0 11.9 11.7 07/28/2005 05:40:00 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 167 4 168 255 11.9 0.1 11.9 11.7 07/28/2005 05:50:00 1.2 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 161 9 172 255 12 0 12.2 11.9 07/28/2005 06:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 155 5 158 255 12.1 0 12.5 11.9 07/28/2005 06:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 118 21 125 255 12.3 0 12.5 12.2 07/28/2005 06:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 98 26 71 255 12.5 0 13 12.5 07/28/2005 06:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 131 0 131 255 12.7 0 13 12.5 07/28/2005 06:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 87 32 80 255 12.8 0 13.3 12.7 07/28/2005 06:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 61 17 46 255 12.9 0 13.3 12.7 07/28/2005 07:00:00 0.9 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 74 8 80 255 12.9 0.1 13.3 12.7 07/28/2005 07:10:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 64 3 59 255 13 0.2 13.5 12.7 07/28/2005 07:20:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 58 8 62 255 13 0.1 13.5 13 07/28/2005 07:30:00 1.2 0.3 1.9 0.4 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 68 11 76 255 13.1 0 13.5 13 07/28/2005 07:40:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 0.5 0.3 1.5 0.4 77 3 67 255 13.1 0 13.3 13 07/28/2005 07:50:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 83 5 77 255 13.1 0 13.3 13 07/28/2005 08:00:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 105 5 100 255 13.2 0 13.3 13 07/28/2005 08:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 109 7 113 255 13.3 0 13.8 13.3 07/28/2005 08:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 106 11 71 255 13.3 0 13.8 13.3 07/28/2005 08:30:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 79 13 71 255 13.4 0 13.8 13.3 07/28/2005 08:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 92 8 93 255 13.5 0.1 13.8 13.3 07/28/2005 08:50:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.5 0.4 1.9 0.4 70 24 65 255 13.5 0.1 13.8 13.3 07/28/2005 09:00:00 1.2 0.4 1.9 0.4 1.1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 53 10 69 255 13.4 0 13.8 13.3 07/28/2005 09:10:00 0.9 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.5 0.4 54 6 51 255 13.4 0 13.8 13.3 07/28/2005 09:20:00 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 75 8 69 255 13.3 0 13.8 13.3 07/28/2005 09:30:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 55 0 55 255 13.4 0 13.8 13.3 07/28/2005 09:40:00 1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 29 12 18 255 13.5 0.1 13.8 13.3 07/28/2005 09:50:00 1.3 0.3 2.3 0.4 1.2 0.4 1.9 0.4 0.7 0.5 1.9 0.4 49 8 48 255 13.5 0.1 13.8 13.3 07/28/2005 10:00:00 1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 33 10 26 255 13.5 0.1 13.8 13.3 07/28/2005 10:10:00 1 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.2 1.5 0.4 18 11 20 255 13.5 0 14.1 13.3 07/28/2005 10:20:00 1.6 0.3 2.6 1.1 1.6 0.3 2.6 1.1 1 0.5 2.3 0.4 19 11 8 255 13.8 0 14.4 13.5 07/28/2005 10:30:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 45 11 31 255 13.9 0 14.6 13.8 07/28/2005 10:40:00 1.5 0.3 2.3 0.7 1.4 0.3 2.6 0.7 0.7 0.4 1.9 0.4 21 16 35 255 13.9 0 14.4 13.8 07/28/2005 10:50:00 1.5 0.4 2.3 0.4 1.5 0.5 2.3 0.4 0.8 0.5 2.3 0.4 15 10 21 255 13.8 0 14.4 13.8 07/28/2005 11:00:00 1.7 0.5 3 0.4 1.7 0.5 2.6 0.4 1.2 0.5 2.3 0.4 31 12 55 255 13.7 0 14.4 13.5 07/28/2005 11:10:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 1.6 0.5 2.6 0.4 31 11 40 255 13.7 0 14.1 13.5 07/28/2005 11:20:00 1.8 0.4 2.6 0.4 1.7 0.5 2.6 0.4 1 0.6 2.3 0.4 20 13 354 255 13.6 0 14.1 13.5 07/28/2005 11:30:00 1.5 0.4 2.3 0.7 1.3 0.5 2.3 0.4 0.7 0.5 1.9 0.4 28 13 15 255 13.7 0 14.4 13.5 07/28/2005 11:40:00 1.3 0.5 2.3 0.4 1.2 0.5 2.6 0.4 0.8 0.5 1.9 0.4 43 12 39 255 13.7 0 14.4 13.5 07/28/2005 11:50:00 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 42 11 66 255 13.7 0 14.4 13.5 07/28/2005 12:00:00 1.9 0.4 2.6 0.7 1.8 0.5 3 0.4 1.4 0.6 2.6 0.4 47 11 37 255 13.7 0 14.1 13.5 07/28/2005 12:10:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.1 1.9 0.5 3 0.7 48 9 71 255 13.5 0 13.8 13.3 07/28/2005 12:20:00 2.1 0.6 3.8 0.7 2.1 0.7 3.4 0.7 1.6 0.8 3.4 0.4 35 16 32 255 13.5 0 13.8 13.3 07/28/2005 12:30:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 0.9 0.6 2.6 0.4 37 22 43 255 13.6 0 14.1 13.5 07/28/2005 12:40:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 57 18 62 255 13.6 0 13.8 13.5 07/28/2005 12:50:00 2.3 0.5 3.4 1.1 2.2 0.6 3.4 0.7 1.8 0.7 3.4 0.4 37 17 1 255 13.8 0 14.4 13.5 07/28/2005 13:00:00 2.1 0.9 3.8 0.4 1.9 1 4.2 0.4 0.9 0.8 3.4 0.4 23 24 16 255 13.9 0 14.6 13.8 07/28/2005 13:10:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 40 16 3 255 14.2 0 14.6 14.1 07/28/2005 13:20:00 2.3 0.8 4.2 0.4 2.3 0.9 4.2 0.4 1.6 0.9 3.8 0.4 24 17 22 255 14.1 0 14.6 13.8 07/28/2005 13:30:00 2.6 0.6 4.2 0.7 2.6 0.6 3.8 0.7 2 0.8 3.8 0.4 41 15 36 255 13.9 0 14.4 13.8 07/28/2005 13:40:00 2.6 0.6 3.8 0.7 2.6 0.6 3.8 0.4 1.8 0.8 3.4 0.4 30 13 31 255 14 0 14.4 13.8 07/28/2005 13:50:00 2.3 0.4 3.4 1.5 2.2 0.4 3.4 1.1 1.5 0.7 3 0.4 21 12 0 255 14.4 0 14.9 14.1 07/28/2005 14:00:00 2.5 0.5 4.2 1.1 2.4 0.6 4.2 0.7 2 0.7 3.8 0.4 40 14 28 255 14.3 0 14.6 14.4 07/28/2005 14:10:00 2.1 0.7 3.8 0.4 2.1 0.7 3.4 0.4 1.5 0.8 3.4 0.4 47 14 36 255 14.3 0 14.6 14.4 07/28/2005 14:20:00 2 0.6 3.4 0.7 1.9 0.6 3.8 0.4 1 0.6 2.6 0.4 41 20 68 255 14.5 0.1 15.2 14.4 07/28/2005 14:30:00 1.8 0.6 3.4 0.7 1.7 0.7 3.4 0.4 1.3 0.6 3 0.4 60 18 65 255 14.5 0 15.2 14.4 07/28/2005 14:40:00 2.6 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2 0.6 3.4 0.4 42 15 43 255 14.4 0 14.9 14.4 07/28/2005 14:50:00 2.3 0.7 4.6 0.7 2.2 0.7 4.6 0.7 1.7 0.5 3 0.4 49 17 33 255 14.4 0 14.9 14.4 07/28/2005 15:00:00 1.9 1 4.6 0.4 1.7 1.1 4.6 0.4 1.2 1 3.8 0.4 59 18 33 255 14.3 0 14.9 14.4 07/28/2005 15:10:00 1.7 0.7 3 0.4 1.5 0.8 3 0.4 1.2 0.8 3.4 0.4 33 13 25 255 14.2 0 14.6 14.1 07/28/2005 15:20:00 2.4 0.5 3.8 1.1 2.3 0.6 3.8 0.7 1.9 0.6 3.4 0.4 51 15 29 255 14.1 0 14.6 13.8 07/28/2005 15:30:00 1.9 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.3 0.7 3 0.4 74 28 84 255 13.9 0 14.4 13.8 07/28/2005 15:40:00 1.3 0.6 3 0.4 1.1 0.6 3 0.4 0.8 0.5 2.6 0.4 87 23 87 255 13.9 0 14.4 13.5 07/28/2005 15:50:00 2.3 0.6 3.8 0.7 2.2 0.7 3.8 0.4 1.8 0.6 3.4 0.7 72 14 52 255 13.7 0 14.1 13.5 07/28/2005 16:00:00 2.6 0.7 4.2 1.1 2.5 0.7 4.2 0.7 2 0.8 3.4 0.4 71 12 73 255 13.5 0 14.1 13.5 07/28/2005 16:10:00 2.3 0.6 3.8 1.1 2.2 0.6 3.8 0.7 1.8 0.6 3.4 0.4 62 15 68 255 13.7 0 14.4 13.5 07/28/2005 16:20:00 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.2 0.7 2.6 0.4 76 17 74 255 13.9 0 14.6 13.8 07/28/2005 16:30:00 1.2 0.7 3 0.4 1 0.7 3 0.4 0.7 0.5 2.3 0.4 83 23 88 255 14 0.1 14.6 13.8 07/28/2005 16:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 55 17 69 255 14 0.1 14.6 13.8 07/28/2005 16:50:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 80 10 87 255 14 0 14.4 13.8 07/28/2005 17:00:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 88 11 98 255 13.9 0 14.4 13.5 07/28/2005 17:10:00 1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 95 10 102 255 13.7 0 14.1 13.5 07/28/2005 17:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 92 7 94 255 13.7 0 14.1 13.5 07/28/2005 17:30:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 89 11 106 255 13.9 0 14.4 13.8 07/28/2005 17:40:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 83 3 85 255 14.1 0.1 14.6 13.8 07/28/2005 17:50:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 95 8 88 255 14.2 0 14.6 14.4 07/28/2005 18:00:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 105 11 134 255 14.4 0 14.9 14.4 07/28/2005 18:10:00 1.2 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 117 13 126 255 14.3 0 14.6 14.4 07/28/2005 18:20:00 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 93 13 118 255 14.4 0 14.9 14.4 07/28/2005 18:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 51 36 69 255 14.5 0 14.9 14.6 07/28/2005 18:40:00 1.1 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 99 9 115 255 14.4 0 14.6 14.4 07/28/2005 18:50:00 1.3 0.5 2.3 0.4 1 0.6 2.3 0.4 0.6 0.5 1.9 0.4 98 10 109 255 14.1 0.1 14.6 13.8 07/28/2005 19:00:00 1.3 0.3 1.9 0.7 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 102 0 102 255 13.9 0 14.6 13.8 07/28/2005 19:10:00 0.8 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 104 0 104 255 13.9 0 14.4 13.8 07/28/2005 19:20:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 115 8 117 255 13.7 0 14.1 13.5 07/28/2005 19:30:00 2 0.4 2.6 0.7 1.8 0.4 2.6 0.4 1.1 0.4 1.9 0.4 132 9 133 255 13.5 0 13.8 13.5 07/28/2005 19:40:00 1.8 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 114 9 113 255 13.5 0 13.8 13.3 07/28/2005 19:50:00 1.6 0.4 2.3 0.7 1.3 0.5 2.3 0.4 0.7 0.4 1.5 0.4 110 8 113 255 13.5 0.1 13.8 13.3 07/28/2005 20:00:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 0.5 0.3 1.9 0.4 108 5 109 255 13.4 0 13.8 13.3 07/28/2005 20:10:00 1.7 0.4 2.6 0.7 1.4 0.4 2.6 0.4 0.8 0.5 1.9 0.4 117 9 112 255 13.3 0 13.8 13.3 07/28/2005 20:20:00 1.6 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.6 0.3 1.5 0.4 114 10 112 255 13.3 0 13.5 13 07/28/2005 20:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 110 13 129 255 13.2 0 13.5 13 07/28/2005 20:40:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 73 36 58 255 13.1 0 13.5 13 07/28/2005 20:50:00 1.7 0.4 2.6 0.7 1.4 0.5 2.6 0.4 0.7 0.5 2.3 0.4 7 8 4 255 13.1 0 13.5 13 07/28/2005 21:00:00 1.3 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 5 9 357 255 12.9 0.1 13.5 12.7 07/28/2005 21:10:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 12 6 4 255 12.8 0 13.3 12.7 07/28/2005 21:20:00 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 15 10 19 255 12.8 0 12.7 12.7 07/28/2005 21:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 16 8 10 255 12.7 0 12.7 12.5 07/28/2005 21:40:00 1.3 0.4 2.3 0.4 1 0.5 1.9 0.4 0.4 0.2 1.5 0.4 88 17 90 255 12.7 0 12.7 12.5 07/28/2005 21:50:00 1.6 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.5 0.2 1.5 0.4 113 8 112 255 12.7 0 12.7 12.7 07/28/2005 22:00:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.6 0.3 1.5 0.4 122 12 113 255 12.7 0 12.7 12.7 07/28/2005 22:10:00 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.4 0.2 1.1 0.4 104 16 101 255 12.7 0 12.7 12.5 07/28/2005 22:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 3 83 255 12.7 0 12.7 12.7 07/28/2005 22:30:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 50 22 27 255 12.7 0 12.7 12.5 07/28/2005 22:40:00 1.8 0.3 2.6 1.1 1.5 0.4 2.3 0.4 0.5 0.2 1.5 0.4 12 5 12 255 12.5 0 12.7 12.5 07/28/2005 22:50:00 2 0.3 2.6 1.1 1.8 0.3 2.3 0.7 0.7 0.4 1.9 0.4 18 7 18 255 12.4 0 12.5 12.5 07/28/2005 23:00:00 1.7 0.4 2.6 0.7 1.5 0.4 2.3 0.4 0.6 0.3 1.9 0.4 51 15 73 255 12.4 0 12.5 12.5 07/28/2005 23:10:00 1.7 0.5 2.6 0.7 1.4 0.5 2.3 0.4 0.5 0.3 1.9 0.4 79 13 84 255 12.4 0 12.5 12.5 07/28/2005 23:20:00 0.9 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.4 0.1 1.1 0.4 122 21 97 255 12.4 0 12.5 12.5 07/28/2005 23:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 134 255 12.4 0 12.5 12.5 07/28/2005 23:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 100 45 40 255 12.4 0 12.5 12.5 07/28/2005 23:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 52 1 52 255 12.4 0 12.5 12.2 07/29/2005 00:00:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 48 4 52 255 12.4 0 12.5 12.2 07/29/2005 00:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 37 12 44 255 12.4 0 12.5 12.2 07/29/2005 00:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 43 18 255 12.3 0 12.5 12.2 07/29/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 255 255 12.3 0 12.2 12.2 07/29/2005 00:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 105 255 12.3 0 12.2 12.2 07/29/2005 00:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 92 23 105 255 12.3 0 12.2 12.2 07/29/2005 01:00:00 0.7 0.3 1.5 0.4 0.4 0 1.1 0.4 0.4 0 0.4 0.4 53 7 73 255 12.2 0 12.2 12.2 07/29/2005 01:10:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.4 0.4 0.1 1.1 0.4 74 4 78 255 12.3 0 12.2 12.2 07/29/2005 01:20:00 1.3 0.4 2.3 0.4 1 0.5 1.9 0.4 0.4 0.2 1.5 0.4 71 15 62 255 12.3 0 12.2 12.2 07/29/2005 01:30:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 26 13 12 255 12.3 0 12.5 12.2 07/29/2005 01:40:00 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 1.1 0.4 50 16 43 255 12.2 0 12.2 12.2 07/29/2005 01:50:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 91 23 108 255 12 0 12.2 11.9 07/29/2005 02:00:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 109 4 111 255 12.1 0 12.2 11.9 07/29/2005 02:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 82 27 59 255 12.1 0 12.2 11.9 07/29/2005 02:20:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 57 7 46 255 12.1 0 12.2 11.9 07/29/2005 02:30:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 44 13 32 255 12 0 12.2 11.9 07/29/2005 02:40:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 65 13 47 255 12 0 12.2 11.9 07/29/2005 02:50:00 1.2 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 90 4 89 255 12 0 12.2 11.9 07/29/2005 03:00:00 1.6 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.4 0.1 1.1 0.4 116 9 116 255 12 0 12.2 11.9 07/29/2005 03:10:00 1.4 0.4 2.6 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 106 9 108 255 12 0 12.2 11.9 07/29/2005 03:20:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 82 6 93 255 12 0 12.2 11.9 07/29/2005 03:30:00 1.3 0.4 2.3 0.4 1 0.5 1.9 0.4 0.4 0 0.4 0.4 92 9 92 255 12 0 12.2 11.9 07/29/2005 03:40:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 66 12 76 255 12 0 12.2 11.9 07/29/2005 03:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 79 12 65 255 12 0 12.2 11.9 07/29/2005 04:00:00 1.1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 66 7 68 255 12 0 12.2 11.9 07/29/2005 04:10:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 44 0 44 255 12 0 11.9 11.9 07/29/2005 04:20:00 1.1 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 35 11 19 255 12 0 12.2 11.9 07/29/2005 04:30:00 1.4 0.3 2.3 0.4 1.1 0.3 1.9 0.4 0.4 0.1 1.1 0.4 33 9 24 255 11.9 0 11.9 11.7 07/29/2005 04:40:00 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 0.5 0.3 1.9 0.4 52 15 66 255 11.7 0 11.9 11.7 07/29/2005 04:50:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 78 12 68 255 11.6 0 11.7 11.4 07/29/2005 05:00:00 2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 0.6 0.4 1.9 0.4 67 13 50 255 11.5 0 11.7 11.4 07/29/2005 05:10:00 1.9 0.5 3.4 0.7 1.6 0.6 3.4 0.4 0.5 0.3 1.9 0.4 45 15 46 255 11.4 0 11.7 11.4 07/29/2005 05:20:00 2 0.5 3.8 0.7 1.8 0.6 3.8 0.4 0.6 0.5 2.6 0.4 44 12 35 255 11.2 0 11.4 11.1 07/29/2005 05:30:00 2.2 0.6 3.4 0.7 2 0.6 3.4 0.4 0.8 0.6 2.6 0.4 35 11 43 255 11.1 0 11.1 11.1 07/29/2005 05:40:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.1 1.1 0.7 3 0.4 34 12 31 255 11 0 11.1 10.9 07/29/2005 05:50:00 2 0.4 3 1.1 1.8 0.4 3 0.7 0.6 0.4 1.9 0.4 20 12 39 255 10.8 0 11.1 10.9 07/29/2005 06:00:00 1.6 0.4 2.6 0.7 1.4 0.5 2.6 0.4 0.4 0.2 1.1 0.4 25 12 21 255 10.7 0 10.9 10.6 07/29/2005 06:10:00 1.5 0.4 2.6 0.4 1.2 0.5 2.6 0.4 0.4 0.2 1.1 0.4 53 10 50 255 10.7 0 10.9 10.6 07/29/2005 06:20:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 0.6 0.3 1.5 0.4 59 10 46 255 10.6 0 10.9 10.6 07/29/2005 06:30:00 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.4 0.2 1.5 0.4 60 11 47 255 10.6 0 10.9 10.6 07/29/2005 06:40:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.5 0.4 68 11 62 255 10.7 0 10.9 10.6 07/29/2005 06:50:00 1.4 0.5 3 0.4 1.2 0.5 2.6 0.4 0.5 0.3 2.3 0.4 59 11 54 255 10.7 0 10.9 10.6 07/29/2005 07:00:00 1.4 0.5 2.3 0.4 1.2 0.5 2.6 0.4 0.5 0.2 1.5 0.4 57 12 62 255 10.8 0 10.9 10.9 07/29/2005 07:10:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 79 23 47 255 10.9 0 10.9 10.9 07/29/2005 07:20:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.7 0.4 93 9 87 255 10.9 0 11.1 10.9 07/29/2005 07:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 110 7 87 255 11.1 0 11.4 11.1 07/29/2005 07:40:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 91 22 89 255 11.3 0 11.4 11.1 07/29/2005 07:50:00 1.6 0.4 2.6 0.7 1.3 0.5 2.6 0.4 0.6 0.4 1.9 0.4 92 12 83 255 11.5 0 11.7 11.4 07/29/2005 08:00:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 0.4 0.2 1.5 0.4 74 9 79 255 11.6 0 11.7 11.4 07/29/2005 08:10:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 64 11 59 255 11.7 0 11.9 11.7 07/29/2005 08:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 66 5 62 255 11.8 0 11.9 11.7 07/29/2005 08:30:00 0.8 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0 0.7 0.4 60 15 39 255 11.9 0 11.9 11.9 07/29/2005 08:40:00 1.2 0.4 2.6 0.4 0.9 0.4 2.3 0.4 0.5 0.3 1.9 0.4 24 11 27 255 12.1 0 12.2 11.9 07/29/2005 08:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 41 36 21 255 12.3 0 12.5 12.2 07/29/2005 09:00:00 0.6 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 64 17 39 255 12.4 0 12.5 12.5 07/29/2005 09:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 56 9 62 255 12.5 0 12.5 12.5 07/29/2005 09:20:00 1.1 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.5 0.4 45 7 46 255 12.6 0 12.7 12.5 07/29/2005 09:30:00 2.2 0.4 3 1.1 2 0.5 3 0.7 1.2 0.6 2.6 0.4 38 11 46 255 12.7 0 12.7 12.5 07/29/2005 09:40:00 2.1 0.5 3 0.7 1.9 0.6 3 0.4 1 0.6 2.3 0.4 56 12 54 255 12.8 0 12.7 12.7 07/29/2005 09:50:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 0.5 0.3 1.5 0.4 58 15 25 255 12.8 0 13.3 12.7 07/29/2005 10:00:00 1 0.6 2.3 0.4 0.8 0.5 3 0.4 0.4 0.1 1.1 0.4 56 10 59 255 12.9 0 13 12.7 07/29/2005 10:10:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.5 0.3 1.9 0.4 64 20 90 255 13.1 0 13.3 12.7 07/29/2005 10:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 81 21 90 255 13.2 0 13.8 13 07/29/2005 10:30:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 89 6 96 255 13.4 0 13.8 13 07/29/2005 10:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 87 0 87 255 13.6 0 14.1 13.3 07/29/2005 10:50:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 86 15 87 255 13.7 0 14.1 13.5 07/29/2005 11:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 0 78 255 13.9 0 14.4 13.5 07/29/2005 11:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 0 78 255 14.2 0 14.6 13.8 07/29/2005 11:20:00 0.5 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 51 28 27 255 14.6 0 15.2 14.4 07/29/2005 11:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 8 9 7 255 15.1 0.1 15.7 14.9 07/29/2005 11:40:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.9 0.4 1 17 353 255 15.3 0 16 15.2 07/29/2005 11:50:00 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 0.4 0.2 1.1 0.4 1 11 1 255 15.5 0 16 15.5 07/29/2005 12:00:00 1.6 0.4 2.6 0.4 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 18 10 26 255 15.7 0 16.3 15.7 07/29/2005 12:10:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 1 7 22 255 15.6 0 16.3 15.5 07/29/2005 12:20:00 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.4 0.2 1.1 0.4 9 9 6 255 15.9 0 16.3 15.7 07/29/2005 12:30:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 7 9 27 255 15.9 0 16.6 15.7 07/29/2005 12:40:00 1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 54 13 61 255 15.9 0 16.6 15.7 07/29/2005 12:50:00 1.2 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0.1 1.1 0.4 16 15 21 255 15.9 0 16.3 15.7 07/29/2005 13:00:00 2 0.7 3.4 0.4 1.8 0.8 3.4 0.4 0.9 0.6 2.6 0.4 16 15 8 255 15.6 0 16.3 15.5 07/29/2005 13:10:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 0.8 0.5 2.3 0.4 9 10 24 255 15.7 0 16.3 15.7 07/29/2005 13:20:00 1.8 0.5 2.6 0.4 1.6 0.5 3 0.4 0.8 0.5 2.3 0.4 16 13 0 255 15.8 0 16.3 15.7 07/29/2005 13:30:00 1.5 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 25 27 21 255 15.9 0 16.3 15.7 07/29/2005 13:40:00 1.7 0.4 3 0.7 1.4 0.5 3 0.4 0.8 0.5 2.6 0.4 17 18 19 255 16.2 0 16.8 16 07/29/2005 13:50:00 2.1 0.5 3.4 0.7 1.9 0.6 3 0.4 1.1 0.6 2.6 0.4 20 12 3 255 16.9 0.2 17.1 16.3 07/29/2005 14:00:00 1.6 0.7 3 0.4 1.3 0.8 3 0.4 0.9 0.7 2.6 0.4 20 18 28 255 17.1 0 17.1 16.8 07/29/2005 14:10:00 1.8 0.5 3 1.1 1.3 0.5 3 0.4 0.8 0.6 2.3 0.4 346 17 347 255 17.1 0 17.1 16.8 07/29/2005 14:20:00 2.1 0.5 3.4 1.1 1.6 0.6 3 0.4 1.2 0.6 3 0.4 333 16 349 255 17.3 0 17.7 17.1 07/29/2005 14:30:00 2.4 0.4 3.4 1.1 2.1 0.6 3 0.4 1.4 0.7 3.4 0.4 351 11 12 255 17.4 0.2 18.2 17.1 07/29/2005 14:40:00 2.1 0.4 3 1.1 1.7 0.5 3 0.4 1.4 0.5 3 0.4 349 10 349 255 18.5 0.5 19.7 17.7 07/29/2005 14:50:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 0.6 0.4 2.3 0.4 3 28 342 255 19.5 0.1 20.3 19.1 07/29/2005 15:00:00 2.7 0.7 4.6 1.1 2.6 0.7 4.6 0.7 2 0.9 3.8 0.4 20 17 22 255 19.4 0 20 19.1 07/29/2005 15:10:00 2.4 0.7 3.8 0.7 2.2 0.7 4.2 0.4 1.4 0.8 3.4 0.4 356 19 349 255 19 0.3 19.4 18.2 07/29/2005 15:20:00 2.2 0.6 3.8 0.7 2 0.6 3.8 0.4 0.8 0.6 2.6 0.4 351 24 343 255 18.1 0 18.2 18 07/29/2005 15:30:00 2.5 0.7 4.2 0.7 2.3 0.7 4.2 0.4 1.5 0.8 3.8 0.4 334 27 4 255 17.8 0 18 17.4 07/29/2005 15:40:00 2.3 0.8 4.2 0.4 2 0.8 4.2 0.4 1.3 1 3.8 0.4 353 21 347 255 17.5 0.2 18.2 17.1 07/29/2005 15:50:00 2.8 0.5 4.2 1.9 2.7 0.5 3.8 1.5 1.7 0.7 3.4 0.4 9 12 10 255 17.1 0.1 17.4 16.8 07/29/2005 16:00:00 2.4 0.6 3.8 0.7 2.3 0.7 3.8 0.4 1.3 0.7 3.4 0.4 2 13 12 255 17 0 17.4 16.8 07/29/2005 16:10:00 1.9 0.7 3.4 0.7 1.5 0.8 3.4 0.4 0.8 0.7 3.4 0.4 352 15 327 255 16.8 0 17.1 16.8 07/29/2005 16:20:00 2.7 0.5 4.2 1.5 2.4 0.6 3.8 0.7 1.5 0.7 3 0.4 354 11 14 255 16.4 0.2 16.8 16.3 07/29/2005 16:30:00 2 0.6 3.4 0.7 1.8 0.7 3.4 0.4 0.9 0.6 2.6 0.4 7 12 8 255 16.1 0 16.3 16 07/29/2005 16:40:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.1 1.7 0.9 3.4 0.4 5 13 12 255 16.6 0 16.8 16.3 07/29/2005 16:50:00 3.2 0.6 4.6 1.9 3.1 0.6 4.6 1.9 2.5 0.9 4.6 0.4 25 13 38 255 16.6 0 16.8 16.6 07/29/2005 17:00:00 3.3 0.5 4.6 2.3 3.2 0.6 4.6 1.9 2.3 0.8 4.2 0.7 16 11 20 255 16.5 0 16.8 16.6 07/29/2005 17:10:00 3.1 0.4 4.2 2.3 3 0.5 4.6 1.9 2.3 0.7 4.2 0.4 14 10 3 255 16.6 0 16.8 16.6 07/29/2005 17:20:00 2.5 0.5 3.8 1.1 2.3 0.5 3.8 0.7 1.4 0.8 3 0.4 16 13 17 255 16.4 0.1 16.8 16.3 07/29/2005 17:30:00 3 0.5 4.2 1.5 2.8 0.6 4.2 1.5 1.9 0.8 4.2 0.4 22 17 40 255 16.1 0 16.6 15.7 07/29/2005 17:40:00 2.6 0.6 4.2 1.1 2.5 0.7 4.2 0.7 1.3 0.8 3.4 0.4 11 10 11 255 15.7 0 16.3 15.7 07/29/2005 17:50:00 1.8 0.4 2.6 0.7 1.6 0.6 2.6 0.4 0.9 0.6 2.6 0.4 9 8 7 255 15.4 0.1 16 15.2 07/29/2005 18:00:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.8 0.5 2.3 0.4 36 22 29 255 15.3 0 15.7 15.2 07/29/2005 18:10:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 1.6 0.6 3 0.4 27 10 11 255 15.3 0 15.7 15.2 07/29/2005 18:20:00 1.9 0.4 3 0.7 1.7 0.5 3 0.7 0.9 0.6 3 0.4 18 8 17 255 15.1 0 15.7 15.2 07/29/2005 18:30:00 1.6 0.3 2.6 1.1 1.2 0.4 2.3 0.4 0.7 0.5 2.3 0.4 33 15 43 255 15 0 15.2 14.9 07/29/2005 18:40:00 1.9 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.2 0.4 2.3 0.4 36 12 26 255 14.9 0 15.2 14.6 07/29/2005 18:50:00 2 0.5 3 0.7 1.8 0.5 2.6 0.4 1.3 0.6 2.6 0.4 30 13 26 255 14.7 0 15.2 14.6 07/29/2005 19:00:00 1.9 0.5 3 0.4 1.6 0.6 2.6 0.4 1.3 0.7 2.6 0.4 25 7 14 255 14.6 0 15.2 14.6 07/29/2005 19:10:00 1.8 0.4 3 0.7 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 30 10 47 255 14.5 0 14.9 14.4 07/29/2005 19:20:00 1.9 0.5 3 0.7 1.7 0.5 3 0.4 1.1 0.6 2.3 0.4 20 12 19 255 14.3 0.1 14.9 14.1 07/29/2005 19:30:00 1.8 0.5 3 0.4 1.5 0.6 2.6 0.4 1.1 0.6 2.3 0.4 27 17 35 255 14.1 0.1 14.6 13.8 07/29/2005 19:40:00 1.3 0.4 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.9 0.4 30 12 30 255 14 0.1 14.6 13.8 07/29/2005 19:50:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 19 6 3 255 13.9 0 14.4 13.5 07/29/2005 20:00:00 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 0.8 0.5 2.3 0.4 21 6 18 255 13.5 0 13.8 13.5 07/29/2005 20:10:00 1.4 0.5 2.6 0.4 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 35 9 40 255 13.4 0 13.5 13.3 07/29/2005 20:20:00 1.9 0.4 3 1.1 1.7 0.5 3 0.4 1 0.5 2.3 0.4 22 12 18 255 13.4 0 13.5 13.3 07/29/2005 20:30:00 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 0.6 0.5 2.6 0.4 30 13 17 255 13.3 0 13.5 13.3 07/29/2005 20:40:00 1 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.5 0.4 43 10 33 255 13.3 0 13.5 13.3 07/29/2005 20:50:00 1 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 74 12 53 255 13.2 0 13.5 13 07/29/2005 21:00:00 1.8 0.3 2.6 0.7 1.5 0.5 2.6 0.4 0.8 0.4 1.9 0.4 79 8 78 255 13.1 0 13.3 13 07/29/2005 21:10:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.4 1.1 0.4 2.3 0.4 67 13 76 255 12.9 0 13.3 12.7 07/29/2005 21:20:00 1.4 0.5 2.6 0.4 1.1 0.6 3 0.4 0.6 0.4 2.3 0.4 54 15 35 255 12.9 0 13 12.7 07/29/2005 21:30:00 2.3 0.5 3.8 1.1 2 0.6 3.4 0.7 1.5 0.7 3 0.4 29 12 37 255 12.9 0 13.3 12.7 07/29/2005 21:40:00 1.5 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 34 12 49 255 12.8 0 13 12.7 07/29/2005 21:50:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 18 7 23 255 12.7 0 12.7 12.5 07/29/2005 22:00:00 1.4 0.4 2.6 0.4 1 0.5 2.6 0.4 0.4 0.2 1.5 0.4 40 16 37 255 12.7 0 13 12.5 07/29/2005 22:10:00 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 25 8 25 255 12.5 0 13 12.5 07/29/2005 22:20:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 21 3 20 255 12.5 0.1 13 12.5 07/29/2005 22:30:00 1.3 0.3 1.9 0.7 0.9 0.4 1.9 0.4 0.4 0.1 1.5 0.4 25 9 24 255 12.4 0 12.7 12.2 07/29/2005 22:40:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 23 2 23 255 12.3 0 12.7 12.2 07/29/2005 22:50:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 24 6 21 255 12.3 0 12.7 12.2 07/29/2005 23:00:00 1.1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 28 11 19 255 12.3 0 12.5 12.2 07/29/2005 23:10:00 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 38 5 42 255 12.3 0 12.5 12.2 07/29/2005 23:20:00 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 39 11 57 255 12.3 0 12.5 12.2 07/29/2005 23:30:00 1.5 0.5 2.3 0.4 1.2 0.6 2.3 0.4 0.6 0.4 1.9 0.4 49 8 40 255 12.4 0 12.5 12.2 07/29/2005 23:40:00 0.8 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.5 0.4 100 30 55 255 12.4 0 12.5 12.2 07/29/2005 23:50:00 0.9 0.7 2.6 0.4 0.7 0.6 2.3 0.4 0.5 0.3 2.3 0.4 71 13 40 255 12.4 0 12.5 12.2 07/30/2005 00:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 44 11 66 255 12.3 0 12.5 12.2 07/30/2005 00:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 46 15 52 255 12.4 0 12.5 12.2 07/30/2005 00:20:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 74 7 80 255 12.4 0 12.5 12.2 07/30/2005 00:30:00 1.5 0.5 2.6 0.4 1.2 0.6 2.3 0.4 0.6 0.4 1.9 0.4 59 15 58 255 12.3 0 12.5 12.2 07/30/2005 00:40:00 2.1 0.5 3.4 1.1 1.9 0.5 3 0.7 1.5 0.6 3 0.4 31 11 33 255 12.4 0 12.5 12.2 07/30/2005 00:50:00 1.1 0.3 2.3 0.4 0.8 0.3 1.9 0.4 0.4 0 0.7 0.4 23 15 33 255 12.3 0 12.5 12.2 07/30/2005 01:00:00 1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.4 0.1 1.5 0.4 60 18 54 255 12.3 0 12.2 12.2 07/30/2005 01:10:00 0.9 0.5 1.9 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 65 15 77 255 12.2 0 12.2 12.2 07/30/2005 01:20:00 1.2 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 61 9 66 255 12.1 0 12.2 11.9 07/30/2005 01:30:00 1.7 0.4 2.3 0.7 1.5 0.4 2.3 0.4 1 0.5 2.3 0.4 39 16 73 255 12.1 0 12.2 12.2 07/30/2005 01:40:00 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 62 19 72 255 12.1 0 12.2 11.9 07/30/2005 01:50:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 70 14 52 255 12.1 0 12.2 11.9 07/30/2005 02:00:00 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.5 2.3 0.4 86 8 79 255 12 0 12.2 11.9 07/30/2005 02:10:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 61 15 72 255 12 0 12.2 11.9 07/30/2005 02:20:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.9 0.4 76 20 74 255 12.1 0 12.2 11.9 07/30/2005 02:30:00 1.5 0.3 2.6 0.7 1.2 0.4 2.6 0.4 0.7 0.4 1.9 0.4 62 19 79 255 12.1 0 12.2 11.9 07/30/2005 02:40:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 64 14 80 255 12 0 12.2 11.9 07/30/2005 02:50:00 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.2 0.7 3 0.4 55 15 60 255 11.9 0 11.9 11.7 07/30/2005 03:00:00 1.3 0.6 3.4 0.4 1 0.7 3 0.4 0.7 0.5 2.6 0.4 59 14 45 255 11.7 0 11.9 11.7 07/30/2005 03:10:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1.6 0.5 3 0.4 45 10 45 255 11.7 0 11.7 11.7 07/30/2005 03:20:00 1.7 0.4 3 0.7 1.6 0.5 3 0.4 0.9 0.5 2.3 0.4 52 17 60 255 11.7 0 11.7 11.7 07/30/2005 03:30:00 1.6 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 42 10 39 255 11.7 0 11.7 11.7 07/30/2005 03:40:00 2.2 0.5 3.4 0.7 2 0.6 3.4 0.7 1.4 0.6 3 0.4 46 12 73 255 11.7 0 11.7 11.7 07/30/2005 03:50:00 1.8 0.4 3 0.7 1.6 0.5 3 0.4 1.1 0.5 2.3 0.4 46 11 40 255 11.7 0 11.7 11.7 07/30/2005 04:00:00 2.2 0.5 3.4 0.7 2 0.5 3 0.4 1.4 0.5 2.6 0.4 50 13 43 255 11.7 0 11.7 11.7 07/30/2005 04:10:00 1.7 0.5 3 0.7 1.5 0.5 3 0.4 0.9 0.6 2.3 0.4 44 13 70 255 11.6 0 11.7 11.7 07/30/2005 04:20:00 2.2 0.5 3.4 0.4 2.1 0.6 3.4 0.7 1.4 0.6 2.6 0.4 48 12 47 255 11.6 0 11.7 11.7 07/30/2005 04:30:00 2.2 0.5 3.4 0.4 2.1 0.6 3.4 0.4 1.4 0.7 3 0.4 51 12 56 255 11.6 0 11.7 11.7 07/30/2005 04:40:00 2 0.6 3.4 0.4 1.8 0.6 3 0.4 1.2 0.6 2.6 0.4 49 12 54 255 11.5 0 11.7 11.4 07/30/2005 04:50:00 2.4 0.5 3.8 1.1 2.3 0.5 3.8 1.1 1.8 0.6 3 0.4 39 12 35 255 11.3 0 11.7 11.1 07/30/2005 05:00:00 2.3 0.5 3.4 1.1 2.2 0.6 3.8 0.7 1.4 0.7 3 0.4 48 12 52 255 11.2 0 11.4 11.1 07/30/2005 05:10:00 2.1 0.6 3.4 0.4 1.9 0.7 3.4 0.4 1.3 0.7 3 0.4 50 16 70 255 11.1 0 11.4 11.1 07/30/2005 05:20:00 1.8 0.7 3.8 0.4 1.5 0.8 3.4 0.4 0.8 0.6 2.6 0.4 48 13 36 255 11.3 0 11.4 11.1 07/30/2005 05:30:00 1.8 0.5 3 0.7 1.6 0.6 3 0.4 0.9 0.5 2.3 0.4 51 14 46 255 11.3 0 11.4 11.1 07/30/2005 05:40:00 2.2 0.5 3.4 0.7 2 0.5 3.4 0.7 1.3 0.6 2.6 0.4 63 14 70 255 11.2 0 11.4 11.1 07/30/2005 05:50:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1 0.6 3 0.4 56 15 49 255 11.1 0 11.4 11.1 07/30/2005 06:00:00 1.2 0.5 2.6 0.4 1 0.6 2.6 0.4 0.5 0.4 1.9 0.4 58 13 57 255 11.1 0 11.4 11.1 07/30/2005 06:10:00 1.2 0.4 2.6 0.4 0.8 0.4 2.3 0.4 0.4 0.1 0.7 0.4 79 14 54 255 11.2 0 11.4 11.1 07/30/2005 06:20:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 86 10 57 255 11.2 0 11.4 11.1 07/30/2005 06:30:00 1.9 0.3 3 1.1 1.7 0.4 3 0.7 0.8 0.5 2.3 0.4 66 8 45 255 11.3 0 11.4 11.1 07/30/2005 06:40:00 1.6 0.5 3 0.4 1.5 0.5 2.6 0.4 0.6 0.4 2.3 0.4 66 11 63 255 11.3 0 11.4 11.4 07/30/2005 06:50:00 2 0.5 3 0.7 1.8 0.6 3.4 0.4 1 0.6 2.6 0.4 64 12 60 255 11.3 0 11.4 11.4 07/30/2005 07:00:00 2.2 0.6 3.8 0.7 2 0.6 3.8 0.4 1.1 0.7 3 0.4 53 19 61 255 11.3 0 11.4 11.1 07/30/2005 07:10:00 2.3 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.2 0.7 3 0.4 60 14 73 255 11.2 0 11.4 11.1 07/30/2005 07:20:00 2.1 0.7 3.8 0.4 2 0.8 3.8 0.4 1.1 0.7 3.4 0.4 74 17 66 255 11.1 0 11.1 11.1 07/30/2005 07:30:00 2.3 0.7 4.2 0.7 2.2 0.8 4.6 0.4 1.1 0.8 3 0.4 79 14 68 255 11.1 0 11.1 11.1 07/30/2005 07:40:00 2.6 0.5 4.2 1.5 2.4 0.5 4.2 1.5 1.3 0.6 2.6 0.4 64 15 39 255 11.1 0 11.1 11.1 07/30/2005 07:50:00 2.2 0.7 3.8 0.4 2 0.8 3.4 0.4 1.1 0.7 2.6 0.4 56 18 60 255 11.1 0 11.1 11.1 07/30/2005 08:00:00 1.9 0.5 3 0.4 1.7 0.6 3 0.4 1 0.6 2.6 0.4 38 12 51 255 11.2 0 11.4 11.1 07/30/2005 08:10:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 42 22 60 255 11.4 0 11.7 11.4 07/30/2005 08:20:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 49 14 52 255 11.6 0 11.7 11.4 07/30/2005 08:30:00 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 36 13 74 255 11.7 0 11.7 11.7 07/30/2005 08:40:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 101 26 136 255 11.7 0 11.7 11.7 07/30/2005 08:50:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 102 21 115 255 11.7 0 11.7 11.7 07/30/2005 09:00:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 64 10 59 255 11.7 0 11.9 11.7 07/30/2005 09:10:00 1.2 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 63 13 58 255 11.9 0 11.9 11.7 07/30/2005 09:20:00 1.4 0.4 2.3 0.4 1.1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 70 9 64 255 11.9 0 11.9 11.9 07/30/2005 09:30:00 1.4 0.3 2.3 0.4 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 55 11 59 255 12 0 11.9 11.9 07/30/2005 09:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 25 19 48 255 12 0 12.2 11.9 07/30/2005 09:50:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 0 9 358 255 12 0 12.2 11.9 07/30/2005 10:00:00 1.2 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.4 0.3 1.9 0.4 15 15 19 255 11.9 0 12.2 11.9 07/30/2005 10:10:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 38 13 29 255 11.9 0 11.9 11.9 07/30/2005 10:20:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.9 0.5 2.3 0.4 48 9 42 255 11.9 0 11.9 11.9 07/30/2005 10:30:00 1.3 0.5 2.3 0.4 1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 46 8 41 255 11.9 0 11.9 11.7 07/30/2005 10:40:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 58 8 56 255 11.9 0 11.9 11.9 07/30/2005 10:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 49 8 49 255 12 0 12.2 11.9 07/30/2005 11:00:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 37 10 55 255 12.1 0 12.2 11.9 07/30/2005 11:10:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.5 0.4 28 15 15 255 12.3 0 12.5 12.2 07/30/2005 11:20:00 1.4 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.6 0.4 1.9 0.4 41 14 23 255 12.5 0 12.5 12.5 07/30/2005 11:30:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 40 13 31 255 12.6 0 12.7 12.5 07/30/2005 11:40:00 1.5 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.4 0.2 1.1 0.4 43 12 34 255 12.8 0 12.7 12.7 07/30/2005 11:50:00 1.5 0.4 2.3 0.4 1.3 0.4 2.6 0.4 0.6 0.4 1.9 0.4 53 15 47 255 12.8 0 12.7 12.7 07/30/2005 12:00:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 66 17 71 255 12.8 0 12.7 12.7 07/30/2005 12:10:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.6 0.4 1.9 0.4 76 15 73 255 12.8 0 12.7 12.7 07/30/2005 12:20:00 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.6 0.5 2.3 0.4 79 20 68 255 12.7 0 12.7 12.7 07/30/2005 12:30:00 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0 0.7 0.4 63 15 56 255 12.7 0 12.7 12.5 07/30/2005 12:40:00 1.4 0.3 2.3 0.4 1.3 0.3 1.9 0.4 0.4 0.2 1.5 0.4 53 8 64 255 12.7 0 12.7 12.5 07/30/2005 12:50:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 47 13 64 255 12.8 0 12.7 12.7 07/30/2005 13:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 18 11 25 255 12.8 0 13 12.7 07/30/2005 13:10:00 1 0.4 2.3 0.4 1 0.4 2.3 0.4 0.4 0.2 1.5 0.4 35 13 27 255 12.8 0 13 12.7 07/30/2005 13:20:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.5 0.4 39 15 59 255 12.8 0 12.7 12.7 07/30/2005 13:30:00 1.9 0.5 2.6 0.4 1.8 0.5 2.6 0.4 0.9 0.6 2.3 0.4 50 9 18 255 12.8 0 12.7 12.7 07/30/2005 13:40:00 2 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.1 0.5 2.3 0.4 40 11 45 255 12.7 0 12.7 12.5 07/30/2005 13:50:00 1.6 0.4 2.3 0.4 1.6 0.4 2.3 0.4 0.7 0.5 1.9 0.4 45 15 45 255 12.5 0 12.7 12.5 07/30/2005 14:00:00 1.5 0.3 2.3 0.7 1.4 0.4 1.9 0.4 0.7 0.4 1.5 0.4 45 8 58 255 12.4 0 12.5 12.5 07/30/2005 14:10:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 42 12 40 255 12.5 0 12.5 12.5 07/30/2005 14:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 35 6 28 255 12.5 0 12.7 12.5 07/30/2005 14:30:00 0.7 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.7 0.4 14 9 40 255 12.5 0 12.7 12.5 07/30/2005 14:40:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 25 12 351 255 12.6 0 12.7 12.5 07/30/2005 14:50:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.7 0.4 48 21 71 255 12.5 0 12.7 12.5 07/30/2005 15:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 74 6 70 255 12.5 0 12.7 12.5 07/30/2005 15:10:00 1.6 0.4 2.3 0.7 1.5 0.4 2.6 0.4 0.8 0.4 2.3 0.4 91 9 104 255 12.5 0 12.5 12.5 07/30/2005 15:20:00 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.4 2.3 0.4 82 17 75 255 12.4 0 12.5 12.5 07/30/2005 15:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 1.1 0.4 71 8 62 255 12.4 0 12.5 12.5 07/30/2005 15:40:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.6 0.4 1.9 0.4 81 12 86 255 12.5 0 12.5 12.5 07/30/2005 15:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 68 10 71 255 12.5 0 12.5 12.5 07/30/2005 16:00:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 65 9 69 255 12.5 0 12.5 12.5 07/30/2005 16:10:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.4 1.9 0.4 85 11 108 255 12.5 0 12.5 12.5 07/30/2005 16:20:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 83 12 64 255 12.4 0 12.5 12.5 07/30/2005 16:30:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 66 21 61 255 12.4 0 12.5 12.5 07/30/2005 16:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.1 0.4 41 10 31 255 12.5 0 12.7 12.5 07/30/2005 16:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 45 6 52 255 12.7 0 12.7 12.5 07/30/2005 17:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 38 1 37 255 12.7 0 12.7 12.5 07/30/2005 17:10:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 52 18 63 255 12.7 0 12.7 12.5 07/30/2005 17:20:00 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.7 0.5 2.3 0.4 61 12 67 255 12.7 0 12.7 12.5 07/30/2005 17:30:00 1.6 0.5 2.6 0.4 1.4 0.5 2.3 0.4 0.9 0.5 1.9 0.4 72 22 129 255 12.7 0 12.7 12.5 07/30/2005 17:40:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 108 17 97 255 12.7 0 12.7 12.5 07/30/2005 17:50:00 2.5 0.6 4.2 1.5 2.3 0.6 4.2 1.5 1.8 0.6 3.8 0.7 99 13 86 255 12.5 0 12.7 12.5 07/30/2005 18:00:00 2.6 0.6 4.2 1.1 2.5 0.6 4.2 0.7 1.9 0.8 3.4 0.4 101 14 87 255 12.5 0 12.5 12.5 07/30/2005 18:10:00 2.5 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.7 0.8 3.4 0.4 101 17 87 255 12.5 0 12.5 12.5 07/30/2005 18:20:00 2.7 0.6 4.2 1.1 2.5 0.6 3.8 1.1 1.7 0.8 3.8 0.4 90 20 89 255 12.4 0 12.5 12.5 07/30/2005 18:30:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 2.4 0.6 4.2 0.7 85 12 102 255 12.4 0 12.5 12.5 07/30/2005 18:40:00 2.8 0.8 4.6 0.7 2.6 0.8 4.6 0.4 1.6 0.9 4.2 0.4 90 16 62 255 12.4 0 12.5 12.5 07/30/2005 18:50:00 2.9 0.5 4.2 1.5 2.7 0.6 4.2 1.1 2 0.7 3.8 0.4 94 12 77 255 12.4 0 12.5 12.5 07/30/2005 19:00:00 2.3 0.7 3.8 0.7 2.1 0.8 3.8 0.4 1.2 0.7 3 0.4 84 18 96 255 12.4 0 12.5 12.5 07/30/2005 19:10:00 2.4 0.7 3.8 0.7 2.3 0.7 3.8 0.7 1.7 0.7 3.4 0.4 79 17 58 255 12.4 0 12.5 12.2 07/30/2005 19:20:00 3.1 0.5 4.6 1.9 3 0.5 4.2 1.9 2 0.6 3.4 0.4 80 9 81 255 12.4 0 12.5 12.5 07/30/2005 19:30:00 2.8 0.6 4.2 1.5 2.7 0.6 4.2 0.7 1.8 0.8 3.8 0.4 77 12 67 255 12.4 0 12.5 12.5 07/30/2005 19:40:00 3.5 0.6 4.9 1.9 3.4 0.7 4.9 1.5 2.4 1 4.6 0.4 72 11 77 255 12.4 0 12.5 12.5 07/30/2005 19:50:00 3 1 5.7 0.4 2.8 1.1 6.1 0.4 1.9 1.2 4.9 0.4 80 17 83 255 12.5 0 12.5 12.5 07/30/2005 20:00:00 1.6 0.6 3 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.3 0.4 105 23 87 255 12.4 0 12.5 12.5 07/30/2005 20:10:00 2.5 0.8 4.9 0.4 2.4 0.8 4.6 0.4 1.4 0.9 3.8 0.4 86 30 59 255 12.4 0 12.5 12.2 07/30/2005 20:20:00 2.1 0.6 4.2 0.4 1.9 0.7 4.2 0.4 1.2 0.7 3 0.4 83 15 81 255 12.3 0 12.5 12.2 07/30/2005 20:30:00 2.5 1 5.3 0.4 2.2 1.2 5.7 0.4 1.5 1 4.2 0.4 71 22 51 255 12.3 0 12.5 12.2 07/30/2005 20:40:00 1.8 0.6 3.8 0.4 1.6 0.7 3.8 0.4 1.3 0.8 3.4 0.4 76 26 47 255 12.2 0 12.2 12.2 07/30/2005 20:50:00 2.1 0.5 3.4 0.4 1.8 0.6 3.4 0.4 1.1 0.6 2.6 0.4 81 21 73 255 12.1 0 12.2 11.9 07/30/2005 21:00:00 2.8 0.9 4.9 1.1 2.6 0.9 4.9 0.7 1.7 1 4.2 0.4 60 12 57 255 12 0 12.2 11.9 07/30/2005 21:10:00 4.2 0.6 5.7 1.9 4.2 0.7 5.7 2.3 3.5 0.8 5.3 1.5 45 9 35 255 11.9 0 12.2 11.9 07/30/2005 21:20:00 3.7 0.6 5.3 1.5 3.5 0.7 5.3 1.5 2.6 0.7 4.6 0.4 50 14 69 255 11.8 0 11.9 11.7 07/30/2005 21:30:00 3.2 0.8 4.9 1.1 3 0.8 4.9 0.7 2.3 0.9 4.2 0.4 39 13 55 255 11.7 0 11.9 11.7 07/30/2005 21:40:00 3.8 0.9 6.8 1.5 3.6 0.9 6.5 1.5 2.9 1 5.7 0.4 40 13 40 255 11.7 0 11.7 11.7 07/30/2005 21:50:00 2.2 1 4.9 0.4 2 1 4.9 0.4 1.3 0.8 3.4 0.4 56 17 25 255 11.5 0 11.7 11.4 07/30/2005 22:00:00 2.3 0.7 3.8 0.4 2 0.7 3.4 0.4 1.3 0.8 3.4 0.4 51 13 58 255 11.4 0 11.7 11.4 07/30/2005 22:10:00 2.3 0.5 3.4 0.7 2 0.6 3 0.4 1.3 0.7 2.6 0.4 46 9 36 255 11.3 0 11.4 11.1 07/30/2005 22:20:00 2.6 0.5 3.8 0.7 2.3 0.6 3.8 0.4 1.4 0.6 3 0.4 49 13 68 255 11.2 0 11.4 11.1 07/30/2005 22:30:00 2.9 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.8 0.7 3.4 0.4 26 9 20 255 11.3 0 11.4 11.1 07/30/2005 22:40:00 2.3 0.5 3.4 1.5 2 0.5 3 0.7 1.4 0.6 3 0.4 35 12 43 255 11.4 0 11.4 11.4 07/30/2005 22:50:00 2.6 0.5 4.2 1.1 2.4 0.5 3.8 1.1 1.6 0.6 3.8 0.4 36 11 47 255 11.4 0 11.7 11.4 07/30/2005 23:00:00 2.8 0.7 4.6 1.1 2.6 0.8 4.2 0.4 1.8 0.9 3.8 0.4 41 12 47 255 11.5 0 11.7 11.4 07/30/2005 23:10:00 2.9 0.8 4.9 1.5 2.7 0.9 4.9 1.1 1.9 1 4.9 0.4 39 16 44 255 11.5 0 11.7 11.4 07/30/2005 23:20:00 1.6 1.2 4.2 0.4 1.4 1.2 4.6 0.4 1.1 1 4.2 0.4 22 15 18 255 11.5 0 11.7 11.4 07/30/2005 23:30:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 120 21 123 255 11.5 0 11.7 11.4 07/30/2005 23:40:00 2.7 0.6 4.6 1.5 2.6 0.6 4.2 1.5 1.8 0.8 3.8 0.4 85 18 72 255 11.6 0 11.7 11.7 07/30/2005 23:50:00 3.2 0.7 4.9 1.5 3.1 0.7 4.6 1.5 2.3 0.8 4.6 0.4 68 14 53 255 11.7 0 11.7 11.7 07/31/2005 00:00:00 3.1 0.9 5.3 0.4 3 0.9 5.3 0.4 2.2 0.8 4.6 0.4 66 19 60 255 11.7 0 11.7 11.7 07/31/2005 00:10:00 3.7 1 6.5 1.1 3.7 1 6.1 1.1 2.8 1.1 5.3 0.4 61 14 55 255 11.7 0 11.9 11.7 07/31/2005 00:20:00 3.6 0.7 5.3 1.5 3.5 0.8 5.3 1.1 2.6 0.9 4.9 0.4 59 19 55 255 11.7 0 11.9 11.7 07/31/2005 00:30:00 3.4 0.6 4.6 2.3 3.3 0.6 4.9 1.5 2.5 0.6 3.8 1.1 50 9 42 255 11.7 0 11.7 11.7 07/31/2005 00:40:00 3.2 0.6 4.9 1.9 3.2 0.6 4.6 1.9 2.3 0.8 4.2 0.4 59 11 45 255 11.6 0 11.7 11.7 07/31/2005 00:50:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 1.9 0.6 3.4 0.4 47 15 65 255 11.7 0 11.7 11.7 07/31/2005 01:00:00 4.2 0.7 6.1 2.3 4 0.8 6.1 1.9 3.3 0.7 5.7 1.1 46 12 46 255 11.7 0 11.7 11.7 07/31/2005 01:10:00 4.4 1.1 7.2 1.9 4.3 1.1 6.8 1.5 3.4 1.2 6.5 0.7 41 13 45 255 11.6 0 11.7 11.4 07/31/2005 01:20:00 4.5 1 8 2.3 4.3 1.1 7.2 1.9 3.3 1.2 6.8 0.4 49 15 23 255 11.4 0 11.7 11.4 07/31/2005 01:30:00 3.9 0.8 6.1 1.9 3.8 0.8 6.1 1.5 2.8 1 5.7 0.4 57 19 33 255 11.2 0 11.4 11.1 07/31/2005 01:40:00 4.7 1.4 8 1.5 4.5 1.5 8.4 1.5 3.6 1.3 7.2 1.1 69 15 77 255 11.1 0 11.1 10.9 07/31/2005 01:50:00 4.3 1.3 7.6 1.1 4.2 1.3 7.2 1.1 3.2 1.2 6.5 0.4 62 19 57 255 10.9 0 11.1 10.9 07/31/2005 02:00:00 3.4 1 5.7 1.1 3.3 1 5.3 0.7 2.3 1.1 4.9 0.4 73 17 50 255 10.9 0 11.1 10.9 07/31/2005 02:10:00 3 1 5.3 0.7 2.9 1 5.7 0.7 2.1 1.1 4.6 0.4 56 21 50 255 10.9 0 11.1 10.9 07/31/2005 02:20:00 3.1 1.1 5.7 0.4 3 1.2 5.7 0.4 2.2 1.1 4.9 0.4 53 17 51 255 10.9 0 11.1 10.9 07/31/2005 02:30:00 4.1 0.7 6.1 2.3 4 0.8 5.7 1.9 3.1 0.7 4.9 1.5 49 13 8 255 11.1 0 11.4 11.1 07/31/2005 02:40:00 3.2 0.8 5.7 1.5 3.1 0.8 5.3 1.1 2.1 1 4.6 0.4 48 14 40 255 11.3 0 11.4 11.1 07/31/2005 02:50:00 2.5 0.9 4.6 0.4 2.4 1 4.6 0.4 1.6 1 4.2 0.4 54 16 49 255 11.3 0 11.4 11.4 07/31/2005 03:00:00 2.9 0.7 4.9 1.1 2.9 0.7 4.6 1.1 1.7 0.8 4.6 0.4 76 17 79 255 11.3 0 11.4 11.1 07/31/2005 03:10:00 3.8 0.8 5.7 1.9 3.9 0.8 6.1 1.9 2.9 0.9 4.9 0.7 70 12 65 255 11.4 0 11.4 11.4 07/31/2005 03:20:00 4.4 0.9 6.8 2.6 4.4 0.8 6.5 2.6 3.5 0.9 5.7 0.4 59 14 43 255 11.4 0 11.4 11.4 07/31/2005 03:30:00 4.9 1 6.8 1.1 4.8 1 6.8 1.9 3.7 1.1 6.1 0.4 49 13 54 255 11.3 0 11.4 11.1 07/31/2005 03:40:00 3.1 0.9 5.3 1.1 3.2 0.9 5.7 1.1 2.3 1 4.6 0.4 45 12 42 255 11.1 0 11.1 11.1 07/31/2005 03:50:00 2.7 1 4.9 0.4 2.8 0.9 4.6 0.4 1.9 1 3.8 0.4 59 12 69 255 11.1 0 11.1 11.1 07/31/2005 04:00:00 2.3 1 4.6 0.4 2.4 0.9 4.6 0.4 1.4 0.8 3.4 0.4 55 13 62 255 11.1 0 11.1 11.1 07/31/2005 04:10:00 2.6 1.3 5.3 0.4 2.7 1.3 5.3 0.4 2 1.4 4.9 0.4 63 13 65 255 11.1 0 11.1 11.1 07/31/2005 04:20:00 4 0.9 6.1 1.9 4.1 0.9 6.1 1.9 3 1 5.3 0.4 68 15 84 255 11.2 0 11.4 11.1 07/31/2005 04:30:00 3.5 1.1 5.7 1.1 3.6 1.1 6.1 1.5 2.7 1.1 5.7 0.4 68 18 71 255 11.3 0 11.4 11.4 07/31/2005 04:40:00 3.2 0.9 5.7 1.1 3.3 0.9 5.7 1.5 2.4 1 5.3 0.4 69 14 53 255 11.3 0 11.4 11.4 07/31/2005 04:50:00 3.6 0.6 4.9 1.5 3.7 0.6 4.9 2.3 2.6 0.8 4.6 0.4 64 15 84 255 11.3 0 11.4 11.1 07/31/2005 05:00:00 3.8 0.7 5.7 1.5 3.8 0.7 5.3 1.5 3 0.7 4.6 1.1 61 13 46 255 11.2 0 11.4 11.1 07/31/2005 05:10:00 3.8 0.7 6.1 1.9 3.8 0.8 6.1 1.9 3 0.8 4.9 1.1 62 12 78 255 11.3 0 11.4 11.1 07/31/2005 05:20:00 4.1 0.9 6.8 2.3 4.1 0.9 6.8 2.3 3.1 0.9 6.5 1.1 67 13 55 255 11.4 0 11.7 11.4 07/31/2005 05:30:00 4.1 1 6.8 1.9 4.1 1 6.8 1.9 3.2 1 6.8 1.5 63 15 55 255 11.5 0 11.7 11.4 07/31/2005 05:40:00 4.3 0.7 6.1 1.9 4.3 0.8 6.1 2.3 3.5 0.7 5.3 1.5 66 14 88 255 11.7 0 11.7 11.7 07/31/2005 05:50:00 3.3 0.8 6.1 1.1 3.3 0.8 6.1 1.1 2.4 0.8 5.3 0.7 74 13 82 255 11.7 0 11.7 11.7 07/31/2005 06:00:00 2.9 0.6 4.9 1.5 3.1 0.5 4.6 1.5 2.2 0.6 4.2 0.4 89 14 106 255 11.7 0 11.7 11.7 07/31/2005 06:10:00 3.1 0.7 4.6 0.7 3 0.6 4.6 0.7 2.2 0.8 3.8 0.4 92 9 87 255 11.8 0.1 11.9 11.7 07/31/2005 06:20:00 2.4 0.6 3.8 0.7 2.3 0.6 3.8 0.7 1.7 0.6 3 0.4 98 13 86 255 12.1 0 12.2 11.9 07/31/2005 06:30:00 1.5 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.1 0.6 2.6 0.4 94 15 105 255 12.3 0 12.5 12.2 07/31/2005 06:40:00 1.9 0.7 3.8 0.4 2.5 0.6 4.2 0.7 1.8 0.7 3.8 0.4 102 14 120 255 12.4 0 12.5 12.5 07/31/2005 06:50:00 0.6 0.4 2.3 0.4 1.2 0.6 2.6 0.4 1 0.5 2.6 0.4 58 27 92 255 12.7 0 12.7 12.5 07/31/2005 07:00:00 0.4 0.2 1.5 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 57 19 50 255 13.3 0.1 13.5 12.7 07/31/2005 07:10:00 0.4 0.1 1.1 0.4 0.5 0.3 2.3 0.4 0.6 0.4 1.9 0.4 42 17 51 255 13.3 0 13.3 13 07/31/2005 07:20:00 0.4 0.1 1.1 0.4 0.6 0.3 1.9 0.4 0.4 0.2 1.9 0.4 6 13 5 255 13.3 0 13.3 13 07/31/2005 07:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 3 11 255 255 13.3 0 13.8 13.3 07/31/2005 07:40:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 26 11 255 255 13.5 0.2 14.1 13 07/31/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 5 14 255 255 14.1 0.1 14.6 13.8 07/31/2005 08:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 357 11 255 255 13.9 0 14.6 13.8 07/31/2005 08:10:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 11 22 4 255 13.9 0 14.4 13.8 07/31/2005 08:20:00 0.4 0.1 0.7 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 350 5 352 255 13.9 0 14.4 13.5 07/31/2005 08:30:00 0.5 0.3 1.5 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 5 10 1 255 14.1 0.1 14.6 13.8 07/31/2005 08:40:00 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 29 18 16 255 14.7 0.4 15.7 13.8 07/31/2005 08:50:00 0.7 0.4 2.6 0.4 1.2 0.5 3 0.4 1.2 0.6 3 0.4 30 22 46 255 15.5 0.2 16.3 15.2 07/31/2005 09:00:00 1.7 0.6 3 0.4 2.2 0.6 3.4 0.7 2.2 0.5 3.4 0.7 34 15 25 255 15.6 0.1 16.3 15.2 07/31/2005 09:10:00 1.6 0.7 3.4 0.4 2.1 0.7 3.8 0.4 1.9 0.7 3.4 0.4 34 12 32 255 15 0 15.7 14.9 07/31/2005 09:20:00 1.8 0.7 3.4 0.4 2.3 0.6 3.8 0.4 1.9 0.6 3.4 0.4 19 15 20 255 14.8 0 15.2 14.6 07/31/2005 09:30:00 2 0.5 3 0.4 2.3 0.4 3.4 1.1 1.6 0.6 3 0.4 13 8 18 255 14.8 0 15.2 14.6 07/31/2005 09:40:00 1.4 0.7 3 0.4 1.8 0.7 3 0.4 1.5 0.7 3 0.4 11 13 356 255 15 0.2 15.7 14.6 07/31/2005 09:50:00 0.7 0.5 2.3 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 7 15 17 255 16 0.5 16.8 15.2 07/31/2005 10:00:00 0.4 0.2 1.5 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 32 27 347 255 16.8 0.3 17.4 16.3 07/31/2005 10:10:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 73 66 255 255 15.8 0.1 16.3 15.5 07/31/2005 10:20:00 0.5 0.2 1.5 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 310 19 297 255 15.5 0 15.7 15.5 07/31/2005 10:30:00 0.5 0.3 1.5 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 283 15 309 255 15.2 0.2 15.7 15.2 07/31/2005 10:40:00 0.4 0.1 1.5 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 313 17 335 255 15 0 15.2 15.2 07/31/2005 10:50:00 1.2 0.6 2.6 0.4 2 0.6 3.4 0.4 1.7 0.7 3.4 0.4 306 16 307 255 15.4 0 15.7 15.2 07/31/2005 11:00:00 0.7 0.5 2.6 0.4 1.5 0.7 3 0.4 1.4 0.6 3 0.4 278 13 270 255 15.3 0.1 15.7 15.2 07/31/2005 11:10:00 0.5 0.2 1.1 0.4 1.2 0.5 2.3 0.4 1.3 0.6 2.6 0.4 294 13 297 255 15.3 0 15.7 15.2 07/31/2005 11:20:00 0.5 0.4 1.9 0.4 1.3 0.5 2.6 0.4 1 0.6 2.6 0.4 308 15 302 255 15.7 0 16.3 15.7 07/31/2005 11:30:00 0.4 0.1 1.1 0.4 0.8 0.5 1.9 0.4 0.9 0.6 2.3 0.4 338 20 350 255 15.9 0 16.3 15.7 07/31/2005 11:40:00 0.4 0.2 1.5 0.4 0.7 0.5 2.3 0.4 0.9 0.6 2.3 0.4 337 33 356 255 16 0 16.3 15.7 07/31/2005 11:50:00 0.4 0.2 1.5 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 319 17 314 255 16.4 0 16.8 16.3 07/31/2005 12:00:00 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 318 23 357 255 16.5 0 16.8 16.3 07/31/2005 12:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 7 22 255 255 16.6 0 16.8 16.6 07/31/2005 12:20:00 0.6 0.5 2.3 0.4 1 0.7 3 0.4 1 0.7 3 0.4 303 38 306 255 16.5 0.1 16.8 16.3 07/31/2005 12:30:00 0.6 0.4 1.9 0.4 1.2 0.6 2.6 0.4 1.1 0.7 2.6 0.4 299 17 314 255 16.1 0 16.6 16.3 07/31/2005 12:40:00 0.4 0 0.7 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 258 45 294 255 16.3 0 16.8 16.3 07/31/2005 12:50:00 0.4 0.2 1.1 0.4 0.7 0.5 2.6 0.4 0.7 0.5 2.6 0.4 301 26 323 255 16.6 0 16.8 16.6 07/31/2005 13:00:00 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 277 43 276 255 16.4 0 16.8 16.3 07/31/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.5 0.4 169 79 255 255 16.4 0 16.6 16.3 07/31/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 66 255 255 16.6 0 16.8 16.6 07/31/2005 13:30:00 1.2 0.6 2.6 0.4 1.9 0.7 3.4 0.4 1.2 0.7 3 0.4 348 17 3 255 16.8 0 17.1 16.6 07/31/2005 13:40:00 1.2 0.5 2.3 0.4 2.1 0.5 3 0.4 1.3 0.7 3 0.4 356 13 1 255 16.4 0 16.8 16.3 07/31/2005 13:50:00 1.1 0.5 2.6 0.4 2.1 0.5 3.4 0.4 1.3 0.6 2.6 0.4 356 11 352 255 16.1 0 16.6 16 07/31/2005 14:00:00 0.7 0.4 1.9 0.4 1.6 0.6 3 0.4 1.1 0.7 2.6 0.4 2 13 24 255 16.2 0 16.6 16.3 07/31/2005 14:10:00 0.7 0.3 1.5 0.4 1.9 0.5 2.6 0.4 1.5 0.6 2.6 0.4 359 9 0 255 17.1 0.2 17.4 16.6 07/31/2005 14:20:00 1 0.6 2.6 0.4 1.9 0.8 3.4 0.4 1.8 0.8 3.4 0.4 20 24 27 255 17.3 0 17.4 17.1 07/31/2005 14:30:00 1.8 0.8 3.4 0.4 2.5 0.8 4.2 0.4 2.2 0.7 4.2 0.4 31 18 14 255 17.1 0 17.4 16.8 07/31/2005 14:40:00 3.5 1.6 7.2 0.4 3.9 1.3 7.6 1.5 3.1 1.4 6.8 0.7 48 29 86 255 16.8 0 17.1 16.6 07/31/2005 14:50:00 4.8 1.5 8.4 0.7 5 1.4 8 1.9 4.3 1.5 7.2 0.7 93 24 82 255 16.3 0.1 16.8 16 07/31/2005 15:00:00 3.8 1.4 7.2 0.4 4 1.3 7.2 1.1 3.3 1.2 6.5 0.4 107 22 118 255 16.1 0 16.6 16 07/31/2005 15:10:00 4.3 1.7 9.5 0.4 4.4 1.7 8.8 0.4 4.1 1.6 8.4 0.4 105 22 108 255 15.7 0 16.3 15.5 07/31/2005 15:20:00 4.6 1.3 8.4 1.5 4.7 1.2 8.4 1.9 4.1 1.1 7.2 1.9 117 20 111 255 15.2 0.1 15.7 15.2 07/31/2005 15:30:00 4.8 1.4 7.6 0.7 5.1 1.3 8 1.5 4.4 1.4 7.6 0.7 108 18 90 255 15.2 0.1 15.7 15.2 07/31/2005 15:40:00 4.7 1.4 8 0.4 5 1.3 8 1.5 4.3 1.5 7.6 0.4 92 19 100 255 16.7 0.7 17.7 15.5 07/31/2005 15:50:00 4.6 1.9 9.5 0.4 5 1.9 9.5 0.4 4 1.7 9.1 0.4 81 19 80 255 16.6 0.5 17.7 16 07/31/2005 16:00:00 5.4 1.4 9.1 1.9 5.8 1.4 9.5 1.9 4.9 1.3 9.1 1.9 83 19 72 255 15.5 0.3 16.3 15.2 07/31/2005 16:10:00 4.4 1.2 7.6 1.5 4.7 1.1 7.6 1.9 4 1.1 6.8 1.5 103 19 101 255 14.7 0.1 15.5 14.4 07/31/2005 16:20:00 4.2 1.2 6.8 0.4 4.4 1.2 7.2 1.1 3.7 1.1 7.6 1.5 103 21 121 255 14.2 0.1 14.9 13.8 07/31/2005 16:30:00 4.2 0.9 6.5 2.3 4.2 0.9 6.5 1.9 3.6 0.9 6.1 1.1 106 15 109 255 14.1 0.1 14.6 14.1 07/31/2005 16:40:00 3.2 1 5.3 0.4 3.2 1 5.7 0.4 2.6 0.8 4.9 0.4 94 19 113 255 14.3 0 14.9 14.1 07/31/2005 16:50:00 2.4 1.1 4.6 0.4 2.4 1 4.6 0.4 2 0.9 4.2 0.4 89 17 75 255 14.4 0 14.9 14.4 07/31/2005 17:00:00 2.4 0.7 4.2 0.4 2.4 0.6 4.2 0.4 1.9 0.8 3.8 0.4 92 19 86 255 14.6 0.1 15.2 14.6 07/31/2005 17:10:00 1.7 0.7 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 76 21 62 255 15.5 0.3 16.3 14.9 07/31/2005 17:20:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 1.1 2.4 0.6 3.4 0.7 43 17 40 255 15.7 0 16.3 15.7 07/31/2005 17:30:00 2.5 0.8 4.9 0.7 2.6 0.8 4.9 1.1 2.4 0.7 4.9 0.7 41 12 43 255 15.8 0 16.3 15.7 07/31/2005 17:40:00 2.9 0.7 4.6 1.1 3.1 0.7 4.6 1.1 2.8 0.7 4.6 1.5 49 15 32 255 15.7 0 16.3 15.7 07/31/2005 17:50:00 3 0.7 4.6 0.4 3.1 0.6 4.6 0.7 2.8 0.7 4.2 0.7 44 15 56 255 15.6 0 16.3 15.5 07/31/2005 18:00:00 2.3 0.6 3.4 0.4 2.5 0.6 3.8 0.4 2.3 0.7 3.8 0.4 43 17 60 255 15.6 0 16.3 15.5 07/31/2005 18:10:00 2.3 0.7 3.4 0.4 2.5 0.6 3.8 0.7 2.2 0.6 3.4 0.7 49 16 54 255 15.6 0 16.3 15.7 07/31/2005 18:20:00 3.1 0.7 4.6 0.7 3.2 0.6 4.6 1.5 2.8 0.7 4.2 1.1 43 15 37 255 15.6 0 16.3 15.5 07/31/2005 18:30:00 2.3 0.8 3.8 0.4 2.4 0.8 4.2 0.4 2.3 0.7 3.8 0.7 48 15 53 255 15.5 0 16 15.5 07/31/2005 18:40:00 2.9 0.6 4.2 1.1 2.9 0.6 4.2 1.1 2.5 0.7 4.2 0.7 34 17 29 255 15.2 0.1 16 15.2 07/31/2005 18:50:00 2.3 0.5 3.8 1.1 2.4 0.6 3.4 1.1 2.1 0.6 3.4 0.4 44 17 59 255 15.2 0 15.7 15.2 07/31/2005 19:00:00 2.2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 56 15 80 255 15 0 15.2 14.9 07/31/2005 19:10:00 1.9 0.5 3.4 0.4 1.9 0.6 3.4 0.4 1.8 0.5 3 0.4 54 12 55 255 15 0 15.2 14.9 07/31/2005 19:20:00 1.9 0.7 3.4 0.4 1.9 0.8 3.4 0.4 1.7 0.5 3 0.4 54 15 85 255 14.8 0 15.2 14.9 07/31/2005 19:30:00 1.7 0.5 2.6 0.4 1.6 0.5 3 0.4 1.6 0.4 2.6 0.4 50 11 55 255 14.8 0 15.2 14.6 07/31/2005 19:40:00 1.1 0.6 3 0.4 0.9 0.6 3 0.4 0.9 0.5 2.3 0.4 63 16 66 255 14.4 0.2 14.9 13.8 07/31/2005 19:50:00 2 0.5 3 0.7 2 0.5 3.4 0.7 1.5 0.6 3 0.4 55 14 49 255 13.9 0 14.6 13.8 07/31/2005 20:00:00 2.3 0.5 3.8 0.7 2.3 0.6 4.2 0.7 1.9 0.6 3.4 0.7 91 20 100 255 13.6 0.2 13.8 13.3 07/31/2005 20:10:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.6 0.6 3 0.4 92 19 116 255 13.5 0 14.1 13.3 07/31/2005 20:20:00 1.8 0.5 3 0.4 1.9 0.5 3 0.4 1.3 0.5 2.3 0.4 102 15 87 255 13.2 0 13.5 13 07/31/2005 20:30:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 1.1 1.7 0.5 3 0.4 95 10 100 255 12.9 0 13.3 12.7 07/31/2005 20:40:00 2.4 0.5 3.8 1.1 2.5 0.5 4.2 0.7 1.8 0.6 3.8 0.4 105 12 109 255 12.4 0.1 12.7 12.2 07/31/2005 20:50:00 2.6 0.6 4.2 1.5 2.7 0.6 4.2 1.5 1.9 0.6 3.8 0.4 102 12 84 255 12.1 0 12.2 11.9 07/31/2005 21:00:00 2.7 0.7 4.2 1.1 2.8 0.7 4.6 1.1 1.9 0.6 3.4 0.7 102 12 100 255 11.9 0.2 12.2 11.7 07/31/2005 21:10:00 2.9 0.7 4.6 1.1 2.9 0.7 4.6 1.1 2.2 0.7 4.2 0.4 103 12 90 255 11.7 0 11.9 11.7 07/31/2005 21:20:00 2.8 0.7 4.6 0.7 2.9 0.7 4.6 1.1 1.7 0.7 3.8 0.4 94 13 97 255 11.7 0 11.9 11.7 07/31/2005 21:30:00 3.3 0.9 5.3 0.7 3.3 0.9 5.3 0.7 2.5 0.9 4.6 0.7 100 12 112 255 11.7 0 11.9 11.7 07/31/2005 21:40:00 3.2 0.6 4.9 1.9 3.3 0.6 4.9 1.9 2.5 0.8 4.6 0.4 97 13 86 255 11.7 0 11.7 11.7 07/31/2005 21:50:00 3.3 0.7 5.7 1.5 3.4 0.6 5.3 1.5 2.5 0.6 4.2 1.1 98 12 87 255 11.7 0 11.7 11.7 07/31/2005 22:00:00 3.4 0.7 5.3 1.5 3.5 0.7 4.9 1.9 2.6 0.7 4.2 0.4 103 14 101 255 11.6 0 11.7 11.4 07/31/2005 22:10:00 3.6 0.9 6.1 2.3 3.9 0.8 6.5 1.9 3 0.9 5.7 0.4 102 14 90 255 11.7 0 11.7 11.7 07/31/2005 22:20:00 3.9 0.7 5.7 1.9 4.2 0.7 5.7 1.9 3.3 0.8 4.9 1.5 102 13 106 255 11.7 0 11.7 11.7 07/31/2005 22:30:00 3.5 0.7 5.3 1.5 3.6 0.6 4.9 1.9 2.7 0.7 4.6 1.1 103 12 108 255 11.5 0 11.7 11.4 07/31/2005 22:40:00 3 0.7 4.9 1.5 3.2 0.7 4.9 1.5 2.4 0.8 4.6 0.7 108 12 108 255 11.4 0 11.7 11.1 07/31/2005 22:50:00 2.4 0.8 4.2 0.7 2.7 0.7 4.6 1.1 1.9 0.7 3.8 0.4 103 15 101 255 11.1 0 11.4 10.6 07/31/2005 23:00:00 0.9 0.7 3.4 0.4 1.4 0.6 3 0.4 0.9 0.5 2.3 0.4 49 22 74 255 10 0.3 10.6 9.6 07/31/2005 23:10:00 1.1 0.6 2.6 0.4 1.5 0.5 3 0.4 0.7 0.4 1.9 0.4 61 10 69 255 9.2 0.1 9.6 9 07/31/2005 23:20:00 2.2 0.4 3 1.1 2.5 0.4 3.4 1.5 1.7 0.4 2.6 0.7 81 8 72 255 8.7 0.1 9 8.5 07/31/2005 23:30:00 2.6 0.4 3.4 1.5 2.9 0.3 3.8 1.9 1.9 0.3 2.6 1.1 84 5 95 255 8.4 0 8.5 8.5 07/31/2005 23:40:00 3.2 0.5 4.6 2.3 3.4 0.5 4.6 2.3 2.3 0.5 3.8 1.1 93 8 90 255 8.2 0 8.5 8 07/31/2005 23:50:00 3.2 0.9 4.9 0.7 3.5 0.8 5.3 1.9 2.4 0.9 4.2 0.4 97 15 98 255 8.4 0.1 8.8 8.3 08/01/2005 00:00:00 2.6 0.8 4.6 0.7 3 0.7 4.6 1.5 2.1 0.6 3.8 0.7 91 13 92 255 8.6 0.1 9 8.5 08/01/2005 00:10:00 2.7 0.4 3.8 1.5 3 0.4 3.8 1.9 1.9 0.5 3 0.4 100 9 106 255 8.6 0 8.8 8.5 08/01/2005 00:20:00 1.1 1 3.4 0.4 1.6 0.8 3.4 0.4 1.1 0.5 2.6 0.4 60 30 98 255 8.3 0 8.8 8.3 08/01/2005 00:30:00 0.7 0.4 1.5 0.4 1.4 0.3 2.3 0.7 0.6 0.3 1.1 0.4 51 20 66 255 8 0 8.3 7.8 08/01/2005 00:40:00 2.2 0.4 3 0.7 2.6 0.3 3.4 1.5 1.6 0.5 2.6 0.4 98 6 98 255 7.8 0 8 7.5 08/01/2005 00:50:00 2.8 0.4 3.8 1.5 3.1 0.4 4.2 1.9 2 0.5 3 0.7 104 8 100 255 7.4 0.1 7.5 7.3 08/01/2005 01:00:00 3 0.6 4.2 1.5 3.3 0.6 4.6 1.9 2.2 0.6 3.8 1.1 111 13 97 255 7.3 0 7.5 7.3 08/01/2005 01:10:00 2.9 0.7 4.6 1.1 3.2 0.6 4.6 1.5 2.1 0.6 3.4 0.4 108 12 108 255 7.4 0 7.5 7.3 08/01/2005 01:20:00 3.4 0.6 4.6 1.1 3.6 0.6 4.9 1.5 2.3 0.6 4.2 1.1 108 12 99 255 7.6 0.1 8 7.5 08/01/2005 01:30:00 3.3 0.7 4.9 1.5 3.5 0.6 4.9 1.9 2.4 0.7 4.2 0.4 107 14 90 255 8.2 0.1 8.5 7.8 08/01/2005 01:40:00 3.4 1 5.3 1.1 3.7 0.8 5.7 1.5 2.4 0.8 4.9 0.7 110 16 98 255 8.6 0 8.8 8.5 08/01/2005 01:50:00 3 0.6 4.9 1.5 3.3 0.5 4.6 1.9 2.4 0.7 3.8 0.4 104 11 131 255 8.8 0 8.8 8.8 08/01/2005 02:00:00 3.1 0.8 5.3 1.5 3.3 0.8 5.3 1.5 2.3 0.8 4.2 0.4 106 12 94 255 8.7 0 9 8.8 08/01/2005 02:10:00 3.3 0.7 4.9 1.5 3.4 0.6 4.9 1.5 2.4 0.7 4.2 0.7 106 13 106 255 8.7 0 8.8 8.8 08/01/2005 02:20:00 3.2 0.8 4.9 1.1 3.4 0.7 4.9 1.5 2.3 0.7 4.6 1.1 105 12 119 255 8.6 0 8.8 8.5 08/01/2005 02:30:00 3.2 0.7 4.9 1.5 3.4 0.6 4.9 1.9 2.5 0.7 4.2 0.7 108 14 104 255 8.6 0 8.8 8.5 08/01/2005 02:40:00 3.1 0.8 4.9 0.7 3.4 0.8 4.9 1.5 2.4 0.8 5.3 0.4 111 14 63 255 8.5 0 8.5 8.5 08/01/2005 02:50:00 3.3 0.9 5.3 0.7 3.5 0.8 5.7 1.1 2.4 0.8 4.6 0.7 111 13 106 255 8.7 0 9 8.5 08/01/2005 03:00:00 3.2 0.8 5.3 1.1 3.4 0.7 5.3 1.5 2.5 0.7 4.2 0.4 111 16 91 255 8.7 0 8.8 8.8 08/01/2005 03:10:00 2.4 0.8 4.6 0.4 2.8 0.7 4.9 1.1 1.7 0.7 4.2 0.4 101 19 109 255 8.5 0 8.8 8.5 08/01/2005 03:20:00 2.4 0.7 4.2 0.4 2.8 0.6 4.6 1.1 1.7 0.6 3 0.4 96 14 104 255 8.3 0 8.5 8.3 08/01/2005 03:30:00 2.3 0.9 4.2 0.4 2.8 0.8 4.9 0.7 2 0.8 3.8 0.4 105 16 118 255 8.1 0 8.3 7.8 08/01/2005 03:40:00 3 1 5.3 0.4 3.3 0.9 5.7 0.7 2.6 0.9 4.6 0.7 107 15 109 255 8.1 0 8.3 8 08/01/2005 03:50:00 3.2 0.7 4.9 1.5 3.5 0.6 5.3 1.9 2.7 0.6 4.2 1.1 106 13 99 255 8.3 0 8.5 8.3 08/01/2005 04:00:00 3.4 0.8 4.9 1.5 3.7 0.7 5.3 1.9 2.7 0.8 4.6 1.1 108 12 115 255 8.3 0 8.5 8.3 08/01/2005 04:10:00 3.3 0.8 5.3 1.1 3.7 0.7 5.3 1.5 2.7 0.7 4.9 0.7 107 14 100 255 8.2 0 8.5 8.3 08/01/2005 04:20:00 3.2 0.6 4.6 1.9 3.5 0.6 4.9 1.9 2.7 0.7 4.6 0.7 103 11 108 255 8.2 0 8.3 8.3 08/01/2005 04:30:00 3 0.8 4.6 0.7 3.3 0.7 4.9 1.5 2.3 0.7 4.6 0.7 112 15 117 255 8.1 0.1 8.3 8 08/01/2005 04:40:00 2.8 0.9 4.9 0.4 3.4 0.8 5.3 0.7 2.3 0.8 4.6 0.4 112 14 106 255 8 0 8.3 8 08/01/2005 04:50:00 3.3 0.9 5.7 1.1 3.8 0.8 5.7 1.9 2.7 0.8 4.9 0.7 108 14 97 255 8.1 0 8.5 8 08/01/2005 05:00:00 3.6 0.7 5.7 1.5 3.8 0.6 5.3 2.3 2.9 0.8 4.9 1.1 106 14 108 255 8.4 0 8.5 8.3 08/01/2005 05:10:00 3.3 0.8 4.9 1.5 3.5 0.7 5.3 1.5 2.7 0.8 4.9 0.7 105 13 100 255 8.7 0 9 8.5 08/01/2005 05:20:00 3.5 0.8 5.3 1.1 3.7 0.8 5.7 1.9 3.1 0.8 4.9 1.1 106 14 81 255 9 0 9 8.8 08/01/2005 05:30:00 2.5 0.8 4.6 0.4 3 0.7 4.9 1.1 2.3 0.6 4.2 0.4 105 15 115 255 9.1 0 9.3 9 08/01/2005 05:40:00 3 1 5.3 0.7 3.6 0.9 5.3 1.1 2.7 0.9 4.9 0.7 108 17 120 255 9.6 0.1 9.8 9.3 08/01/2005 05:50:00 3.3 1.2 6.8 0.7 4 1.1 6.8 1.5 3.2 1 5.7 0.7 109 17 100 255 10.1 0 10.6 9.8 08/01/2005 06:00:00 2.9 1 5.3 0.4 3.6 0.8 5.3 1.9 3 0.8 5.3 1.1 105 17 100 255 10.7 0.1 11.1 10.3 08/01/2005 06:10:00 2.8 1.1 5.3 0.4 3.5 1 5.3 0.7 2.8 0.9 4.9 0.4 103 20 112 255 11 0 11.1 10.9 08/01/2005 06:20:00 2.5 0.9 4.6 0.4 3.1 0.8 5.3 1.1 2.4 0.9 4.2 0.4 91 17 78 255 11.3 0 11.4 10.9 08/01/2005 06:30:00 2 0.9 3.8 0.4 2.5 0.8 4.2 0.4 2.2 0.8 4.2 0.4 87 13 76 255 11.5 0 11.7 11.4 08/01/2005 06:40:00 2 0.8 4.2 0.4 2.3 0.7 4.2 0.7 1.8 0.6 3.8 0.4 72 20 84 255 11.5 0 11.7 11.4 08/01/2005 06:50:00 2.9 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.5 0.6 4.2 1.1 94 15 97 255 11.7 0 11.7 11.7 08/01/2005 07:00:00 3.2 0.7 4.9 0.7 3.4 0.7 4.9 1.1 2.9 0.8 4.6 0.7 97 12 88 255 11.7 0 11.7 11.7 08/01/2005 07:10:00 3 0.7 4.6 1.1 3.1 0.7 4.6 1.1 2.6 0.8 4.2 0.7 96 13 95 255 11.8 0 12.2 11.7 08/01/2005 07:20:00 3.1 1 4.9 1.1 3.3 0.9 5.3 1.1 2.8 0.9 4.9 1.1 96 12 101 255 12.3 0 12.7 12.2 08/01/2005 07:30:00 3.3 0.6 4.6 1.1 3.4 0.6 4.9 1.5 2.9 0.7 4.9 1.1 97 13 102 255 12.9 0.1 13.5 12.7 08/01/2005 07:40:00 3.5 0.7 4.9 1.5 3.5 0.7 4.9 1.5 3 0.7 4.6 1.5 100 12 94 255 13.5 0.2 14.4 13.3 08/01/2005 07:50:00 2.7 0.9 4.9 0.7 2.8 0.8 4.9 0.7 2.5 0.9 4.6 0.4 94 17 108 255 14.1 0.1 14.6 13.8 08/01/2005 08:00:00 1.9 0.8 3.8 0.4 1.9 0.8 4.2 0.4 1.8 0.7 3.4 0.4 83 23 109 255 14.7 0.3 15.5 14.4 08/01/2005 08:10:00 2.5 0.8 3.8 0.4 2.5 0.7 3.8 0.4 2.5 0.7 4.2 0.7 92 15 80 255 15.1 0.1 15.7 15.2 08/01/2005 08:20:00 2.2 0.8 4.2 0.4 2.2 0.8 4.2 0.4 2 0.8 4.2 0.4 82 20 97 255 15.2 0.1 15.7 15.2 08/01/2005 08:30:00 2.5 0.6 3.8 1.1 2.5 0.6 4.2 0.7 2.3 0.6 3.8 0.4 78 13 71 255 15.7 0.1 16.3 15.5 08/01/2005 08:40:00 2.5 0.6 3.8 0.7 2.5 0.6 3.8 0.4 2.2 0.8 3.8 0.4 83 17 79 255 15.7 0 16.3 15.7 08/01/2005 08:50:00 2.4 0.8 4.2 0.4 2.4 0.8 3.8 0.4 2.1 0.8 3.8 0.4 91 19 87 255 15.6 0 16 15.5 08/01/2005 09:00:00 2.5 1 4.2 0.4 2.6 1 4.6 0.4 2.2 0.8 4.2 0.4 89 21 76 255 15.6 0 16 15.5 08/01/2005 09:10:00 2.3 0.7 3.8 0.4 2.3 0.7 3.8 0.4 2.1 0.7 3.8 0.4 71 18 108 255 16.1 0.3 16.8 15.7 08/01/2005 09:20:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.4 0.8 4.6 0.7 44 17 43 255 16.8 0 17.1 16.6 08/01/2005 09:30:00 2.7 0.7 4.2 1.1 2.7 0.7 4.2 0.7 2.5 0.6 3.8 0.4 46 15 74 255 16.7 0 17.1 16.6 08/01/2005 09:40:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 2 0.6 3 0.4 76 26 81 255 17.1 0 17.4 16.8 08/01/2005 09:50:00 2.1 0.9 3.8 0.4 2 0.8 3.8 0.4 1.8 0.8 3 0.4 96 24 103 255 17.2 0 17.4 16.8 08/01/2005 10:00:00 2.4 0.7 4.2 0.7 2.4 0.7 3.8 0.7 2.3 0.6 3.8 1.1 57 21 37 255 17.8 0 18 17.4 08/01/2005 10:10:00 2.8 0.8 4.6 1.1 2.8 0.8 4.6 0.4 2.3 0.7 3.8 0.7 82 16 96 255 18.1 0.1 18.5 17.7 08/01/2005 10:20:00 2.6 0.7 4.2 0.7 2.5 0.7 4.2 0.7 2.1 0.8 3.8 0.4 32 32 82 255 18.7 0.4 20 18.2 08/01/2005 10:30:00 2.8 0.7 4.9 1.5 2.8 0.7 4.9 1.5 2.6 0.6 4.2 1.1 38 11 36 255 19.2 0 19.7 19.1 08/01/2005 10:40:00 1.4 0.7 3.8 0.4 1.4 0.6 3.8 0.4 1.3 0.6 2.6 0.4 24 29 0 255 19.4 0.2 20.5 19.1 08/01/2005 10:50:00 1.5 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1.5 0.7 3.4 0.4 22 18 30 255 19.7 0.2 20.3 19.1 08/01/2005 11:00:00 1.7 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.7 0.6 3.4 0.4 9 30 33 255 19.3 0 20 19.1 08/01/2005 11:10:00 1.9 0.7 3.8 0.4 1.7 0.7 3.4 0.4 1.5 0.6 3 0.4 357 20 348 255 19.2 0 19.7 19.1 08/01/2005 11:20:00 1.6 0.7 3.4 0.4 1.5 0.6 3 0.4 1.4 0.6 3 0.4 2 20 345 255 19.2 0 19.7 19.1 08/01/2005 11:30:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.6 0.6 3 0.4 354 15 343 255 18.9 0.2 19.7 18.5 08/01/2005 11:40:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 1.1 0.6 3 0.4 351 23 333 255 19 0.1 19.4 18.5 08/01/2005 11:50:00 1.2 0.6 2.6 0.4 1.3 0.7 3 0.4 1.2 0.6 2.6 0.4 0 23 7 255 19.1 0.1 19.4 18.8 08/01/2005 12:00:00 2.3 0.9 4.6 0.4 2.3 0.8 4.2 0.4 1.9 0.8 3.8 0.4 346 19 322 255 19.2 0 19.7 19.1 08/01/2005 12:10:00 2 0.5 3.4 0.4 2.1 0.6 3.8 0.4 1.8 0.6 3 0.4 358 14 5 255 19.5 0 20 19.1 08/01/2005 12:20:00 1.6 0.5 3 0.4 1.8 0.5 3 0.4 1.6 0.5 3 0.4 25 16 15 255 19.1 0.1 19.4 18.8 08/01/2005 12:30:00 1.4 0.6 2.6 0.4 1.6 0.6 3 0.4 1.5 0.5 2.6 0.4 19 23 336 255 19.7 0 20.3 19.4 08/01/2005 12:40:00 1 0.9 4.2 0.4 1 1 4.2 0.4 1.1 0.8 4.6 0.4 25 69 310 255 20 0.1 20.5 19.7 08/01/2005 12:50:00 2.4 1.2 4.9 0.4 2.4 1.1 4.9 0.4 2.2 1 4.2 0.4 310 22 315 255 20.5 0.1 21.1 20.3 08/01/2005 13:00:00 1.8 1.2 4.2 0.4 1.9 1.2 4.6 0.4 1.8 1 3.8 0.4 308 21 311 255 19.9 0 20.3 19.7 08/01/2005 13:10:00 2.1 0.8 3.8 0.4 2.3 0.8 3.8 0.7 2.2 0.7 3.8 0.4 311 11 325 255 19.9 0 20 19.7 08/01/2005 13:20:00 1.9 1 4.6 0.4 2.1 1 4.2 0.4 1.9 0.9 4.2 0.4 302 27 295 255 19.5 0.2 20.3 19.1 08/01/2005 13:30:00 1.9 0.8 3.8 0.4 2.3 0.8 4.2 0.4 2.1 0.8 4.2 0.4 305 17 290 255 18.8 0.2 19.1 18.2 08/01/2005 13:40:00 1.2 0.6 2.6 0.4 1.9 0.7 3.4 0.4 1.6 0.7 3.4 0.4 310 22 298 255 18.2 0 18.5 18 08/01/2005 13:50:00 0.7 0.3 1.5 0.4 1.3 0.5 2.3 0.4 1.2 0.6 2.6 0.4 314 29 261 255 18.3 0 18.8 18 08/01/2005 14:00:00 0.5 0.3 1.5 0.4 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 10 22 13 255 18.3 0 18.8 18 08/01/2005 14:10:00 0.5 0.2 1.5 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 329 32 283 255 18.6 0.1 19.1 18.2 08/01/2005 14:20:00 0.9 0.5 1.9 0.4 1.4 0.5 2.3 0.4 1.5 0.5 2.6 0.4 294 14 301 255 18.5 0.2 19.1 18.2 08/01/2005 14:30:00 1.2 0.5 2.3 0.4 1.6 0.6 3 0.4 1.6 0.6 3 0.4 279 10 291 255 18.2 0.2 18.8 17.7 08/01/2005 14:40:00 1.7 0.6 3 0.4 2 0.6 3.4 0.4 1.8 0.8 3.4 0.4 303 17 319 255 17.9 0 18.2 17.7 08/01/2005 14:50:00 1.7 0.7 3.4 0.4 2 0.7 4.2 0.4 1.3 0.8 3 0.4 339 23 328 255 17.8 0 18.2 17.7 08/01/2005 15:00:00 2.5 0.8 4.2 0.4 2.7 0.7 4.6 0.7 2 0.9 4.2 0.4 350 15 0 255 17.5 0.1 18.2 17.1 08/01/2005 15:10:00 1.9 1 4.2 0.4 2.3 0.9 4.2 0.7 1.3 0.8 4.2 0.4 345 13 337 255 17.2 0 17.4 17.1 08/01/2005 15:20:00 2.3 1 4.9 0.4 2.6 1 4.9 0.4 1.9 0.8 4.6 0.4 344 15 44 255 16.8 0 17.7 16.8 08/01/2005 15:30:00 2 0.9 4.6 0.4 2.5 0.8 4.9 0.4 1.5 0.9 3.8 0.4 3 18 0 255 16.7 0 16.8 16.6 08/01/2005 15:40:00 2.8 1.2 6.1 0.4 3.3 1.1 6.5 1.1 2.6 1.1 5.3 0.4 28 19 19 255 16.8 0 16.8 16.8 08/01/2005 15:50:00 3.5 0.8 5.7 1.5 4 0.8 6.1 1.9 3.2 0.8 5.7 1.5 31 13 34 255 16.8 0 16.8 16.8 08/01/2005 16:00:00 3.2 0.7 4.6 1.5 3.7 0.6 5.3 1.9 2.9 0.7 4.6 0.7 22 13 35 255 16.9 0 17.1 16.8 08/01/2005 16:10:00 2.9 1.3 6.1 0.4 3.4 1.2 6.5 1.1 2.5 1.1 5.7 0.4 22 16 33 255 17 0 17.1 16.8 08/01/2005 16:20:00 3.8 1.3 6.5 0.4 4.3 1.2 6.5 1.5 3.1 1.4 6.1 0.4 15 15 10 255 16.9 0 17.1 16.8 08/01/2005 16:30:00 5.5 1.1 8.8 2.6 5.8 1.1 9.1 3.4 4.4 1.3 8 1.5 15 11 13 255 16.4 0.2 16.8 16 08/01/2005 16:40:00 6 1.3 9.1 2.3 6.3 1.2 9.1 2.6 5 1.5 8.8 1.9 19 12 19 255 15.6 0.3 16.3 15.2 08/01/2005 16:50:00 5.5 1.2 9.1 1.9 5.9 1.2 9.5 3 3.9 1.5 8 1.1 13 13 11 255 14.9 0 15.5 14.6 08/01/2005 17:00:00 5.1 1.3 8.8 1.1 5.4 1.2 8.8 2.3 3.9 1.3 8 0.7 8 13 15 255 14.5 0 15.2 14.4 08/01/2005 17:10:00 6.3 1.5 9.5 2.3 6.5 1.4 9.5 1.9 4.8 1.5 8.8 1.5 14 13 21 255 14.3 0.1 14.6 14.1 08/01/2005 17:20:00 4.6 1.2 7.2 1.1 4.9 1.1 7.2 2.3 3.6 1.4 6.8 0.7 20 16 12 255 14.2 0.1 14.6 13.8 08/01/2005 17:30:00 3.6 1.3 7.2 0.7 4 1.2 7.2 1.1 3.3 1.3 7.2 0.4 25 20 43 255 13.9 0 14.6 13.8 08/01/2005 17:40:00 1.6 1.1 5.3 0.4 2.2 1.1 4.9 0.4 1.4 0.8 3.8 0.4 6 21 0 255 13.7 0.1 14.1 13.5 08/01/2005 17:50:00 3.3 1.7 7.6 0.4 4 1.4 7.6 1.5 3.2 1.3 7.6 0.7 18 15 17 255 13.4 0 13.8 13 08/01/2005 18:00:00 5.2 0.8 7.6 2.6 5.6 0.8 7.6 3.4 4.5 1 6.8 2.3 31 11 31 255 13.1 0.1 13.5 12.7 08/01/2005 18:10:00 3.8 0.9 5.3 1.5 4.2 0.8 6.1 2.3 3.3 1 5.7 0.7 20 11 28 255 12.9 0 13.3 12.7 08/01/2005 18:20:00 3.4 0.7 5.3 1.5 3.8 0.7 5.7 2.3 2.7 0.8 4.6 0.7 22 14 24 255 12.6 0 12.7 12.5 08/01/2005 18:30:00 4.1 1 6.5 1.1 4.4 1 6.8 1.5 3.5 1 5.7 1.1 34 13 39 255 12.6 0 13 12.5 08/01/2005 18:40:00 3.5 0.8 5.7 0.4 3.9 0.7 5.7 1.9 3.1 0.7 5.3 0.7 46 13 42 255 12.5 0 13 12.5 08/01/2005 18:50:00 3.1 0.9 4.9 1.1 3.6 0.8 5.3 1.5 2.8 0.8 4.6 1.1 56 15 47 255 12.4 0.1 12.7 12.2 08/01/2005 19:00:00 3.2 1.1 5.7 0.7 3.8 1 5.7 1.9 3.1 0.9 6.1 1.5 57 15 60 255 12.3 0 12.7 12.2 08/01/2005 19:10:00 3.5 0.8 5.3 1.5 4 0.8 5.7 2.3 3.2 0.9 4.9 1.1 65 17 55 255 12.3 0 12.7 12.2 08/01/2005 19:20:00 3.7 1 6.1 1.5 4.1 0.9 6.5 1.9 3.3 1 5.7 0.4 67 14 63 255 12.2 0 12.7 11.9 08/01/2005 19:30:00 3.5 1.2 6.1 1.1 4.1 1 6.8 2.3 3 1.1 6.5 1.1 76 16 88 255 12.1 0 12.5 11.9 08/01/2005 19:40:00 4.3 1.1 7.2 1.1 4.9 1 7.2 2.3 3.9 1.1 6.5 1.5 77 13 92 255 12 0 12.5 11.9 08/01/2005 19:50:00 4.3 1.5 8 0.4 4.9 1.3 8.8 1.5 4.1 1.2 6.8 0.7 75 16 88 255 12.1 0 12.7 11.9 08/01/2005 20:00:00 4.2 1.1 6.5 1.5 4.7 1 6.8 2.3 3.9 1.1 6.8 1.1 72 17 74 255 12.3 0 12.7 12.2 08/01/2005 20:10:00 3.8 1.1 6.5 1.1 4.4 1 7.2 1.9 3.4 1 6.5 1.1 80 16 100 255 12.3 0 12.7 12.2 08/01/2005 20:20:00 3.1 1.1 6.5 0.7 3.8 1 6.5 1.9 2.9 0.9 5.7 1.1 84 13 86 255 12.3 0 12.7 12.2 08/01/2005 20:30:00 2.7 1 4.9 0.7 3.3 0.9 5.7 1.1 2.5 0.8 4.6 1.1 81 16 95 255 12.3 0 12.5 12.2 08/01/2005 20:40:00 2.9 0.9 5.7 0.7 3.4 0.8 6.1 1.1 2.8 0.8 5.3 1.1 79 13 71 255 12.4 0 12.7 12.2 08/01/2005 20:50:00 3.3 0.9 6.1 1.1 3.9 0.8 6.1 1.5 3.2 0.8 5.7 1.5 86 12 63 255 12.6 0 12.7 12.5 08/01/2005 21:00:00 3.7 1.3 7.6 1.1 4.2 1.2 8 1.9 3.6 1.2 7.6 1.9 74 15 74 255 12.8 0 13 12.7 08/01/2005 21:10:00 4.2 1.3 7.6 0.4 4.7 1.3 8 1.1 3.8 1.2 8 1.1 68 17 51 255 12.9 0 13 12.7 08/01/2005 21:20:00 4.9 1.3 8 1.9 5.3 1.3 8.4 2.3 4.3 1.3 7.2 1.1 66 17 73 255 12.9 0 13 12.7 08/01/2005 21:30:00 4.7 1.7 8.8 0.7 5.1 1.6 9.5 2.3 4.4 1.5 8.4 1.9 57 16 38 255 12.8 0 13 12.7 08/01/2005 21:40:00 4.4 1 6.8 1.1 4.8 1 7.2 1.1 3.9 1.1 7.6 1.1 63 17 75 255 12.5 0 12.7 12.5 08/01/2005 21:50:00 5.2 1.1 8.4 2.3 5.7 1.1 8.8 2.6 4.6 1.1 7.2 1.9 55 15 74 255 12.3 0 12.5 12.2 08/01/2005 22:00:00 3.8 1 6.5 1.5 4.3 1 7.2 1.9 3.5 1 6.5 1.5 58 15 71 255 11.9 0.1 12.2 11.7 08/01/2005 22:10:00 3.7 0.9 6.1 1.5 4.3 0.9 6.5 2.3 3.3 0.9 5.7 1.5 75 14 68 255 11.7 0 11.9 11.7 08/01/2005 22:20:00 3.5 0.7 5.3 1.1 4.2 0.7 5.7 1.9 3.1 0.9 5.3 0.4 72 13 76 255 11.5 0 11.7 11.4 08/01/2005 22:30:00 4.1 0.8 6.1 1.9 4.7 0.8 6.8 3 3.6 1 6.5 0.7 69 14 57 255 11.5 0 11.7 11.4 08/01/2005 22:40:00 3.6 1 6.1 1.1 4.2 1 6.8 2.3 3.2 1.1 6.5 0.4 68 15 74 255 11.5 0 11.7 11.4 08/01/2005 22:50:00 2.6 0.8 4.6 0.4 3.3 0.7 4.9 1.5 2.3 0.7 4.2 0.4 79 11 61 255 11.4 0 11.4 11.4 08/01/2005 23:00:00 2.5 0.6 3.8 0.7 3.3 0.5 4.6 1.9 2.4 0.6 4.2 1.1 88 9 79 255 11.4 0 11.4 11.4 08/01/2005 23:10:00 2 0.7 3.4 0.4 2.7 0.6 4.2 0.7 1.8 0.5 3 0.4 102 13 89 255 11.5 0 11.7 11.4 08/01/2005 23:20:00 2.2 0.8 3.8 0.4 2.8 0.7 4.2 0.7 2 0.6 3.4 0.4 111 12 126 255 11.5 0 11.7 11.4 08/01/2005 23:30:00 2.8 0.6 3.8 0.7 3.3 0.5 4.6 1.5 2.4 0.6 3.8 0.4 107 9 117 255 11.7 0 11.7 11.7 08/01/2005 23:40:00 2.4 0.5 3.4 1.1 3.1 0.4 4.2 1.9 2.4 0.5 3.8 1.1 96 9 96 255 11.7 0 11.7 11.7 08/01/2005 23:50:00 2.4 0.7 3.8 0.4 3.2 0.6 4.9 1.5 2.4 0.6 4.2 1.1 100 9 96 255 11.7 0 11.7 11.7 08/02/2005 00:00:00 1.4 0.8 3.4 0.4 2.2 0.8 4.2 0.4 1.7 0.6 3 0.4 87 15 101 255 11.7 0 11.7 11.7 08/02/2005 00:10:00 1.8 0.7 3.4 0.4 2.4 0.6 3.8 0.4 1.8 0.5 3 0.4 101 14 109 255 11.7 0 11.7 11.7 08/02/2005 00:20:00 2.1 0.6 3.4 0.4 2.9 0.5 4.2 1.5 2.2 0.6 3.8 0.7 96 10 105 255 11.7 0 11.7 11.7 08/02/2005 00:30:00 2.2 0.6 3.8 0.7 3 0.5 4.6 1.9 2.3 0.6 3.8 0.7 93 8 85 255 11.7 0 11.7 11.7 08/02/2005 00:40:00 2.7 0.6 3.8 0.7 3.4 0.6 4.6 1.5 2.5 0.6 3.8 0.7 108 12 87 255 11.7 0 11.9 11.7 08/02/2005 00:50:00 2.4 0.8 4.2 0.4 3.1 0.8 4.6 0.4 2.3 0.6 4.2 0.7 120 14 112 255 11.7 0 11.9 11.7 08/02/2005 01:00:00 2.7 0.7 4.2 1.1 3.3 0.6 4.6 1.5 2.4 0.6 3.8 0.4 118 13 124 255 11.8 0 11.9 11.7 08/02/2005 01:10:00 2.9 0.7 4.2 0.7 3.6 0.6 4.9 1.9 2.7 0.6 4.2 1.1 107 11 100 255 11.8 0 11.9 11.7 08/02/2005 01:20:00 2 0.6 3.4 0.7 2.7 0.5 3.8 1.1 2.1 0.5 3.8 0.7 99 11 88 255 11.8 0 11.9 11.7 08/02/2005 01:30:00 2.5 0.9 4.9 0.4 3.1 0.8 5.3 1.5 2.3 0.9 4.2 0.4 108 13 144 255 11.8 0 11.9 11.7 08/02/2005 01:40:00 3.4 1 5.3 0.4 3.9 0.8 5.7 1.5 3 0.8 4.9 0.7 112 12 110 255 11.9 0 11.9 11.7 08/02/2005 01:50:00 3.5 0.9 6.1 1.1 3.8 0.8 6.1 1.9 3 0.8 5.3 0.7 107 13 113 255 11.9 0 11.9 11.9 08/02/2005 02:00:00 4 0.9 6.1 1.9 4.3 0.8 6.5 1.9 3.3 0.8 5.7 1.1 99 13 122 255 12 0 11.9 11.9 08/02/2005 02:10:00 4.1 1 6.1 1.5 4.6 0.8 6.1 2.3 3.5 0.9 5.7 1.5 92 12 109 255 12 0 12.2 11.9 08/02/2005 02:20:00 4.3 1 6.5 1.5 4.6 1 6.8 2.3 3.6 1 6.1 0.7 90 14 94 255 12.1 0 12.2 11.9 08/02/2005 02:30:00 4.2 0.7 6.8 2.6 4.4 0.7 6.8 2.6 3.5 0.9 6.1 1.1 97 14 79 255 12 0 12.2 11.9 08/02/2005 02:40:00 3.8 0.9 5.7 1.5 4 0.8 6.1 1.9 3.3 0.8 5.3 1.5 101 13 100 255 11.9 0 11.9 11.7 08/02/2005 02:50:00 4.3 1.1 6.8 0.7 4.5 1 6.8 1.9 3.4 1.1 6.5 0.7 93 13 102 255 11.7 0 11.9 11.7 08/02/2005 03:00:00 4.3 1 6.5 1.5 4.6 0.8 6.5 2.6 3.8 0.8 6.1 1.1 100 12 97 255 11.7 0 11.9 11.7 08/02/2005 03:10:00 4.2 1 6.5 1.9 4.5 0.9 6.8 2.3 3.5 0.8 5.7 1.1 100 14 90 255 11.7 0 11.7 11.7 08/02/2005 03:20:00 4.1 1.3 7.6 1.1 4.3 1.2 8 1.5 3.2 1.3 6.1 0.4 83 15 102 255 11.9 0 12.2 11.7 08/02/2005 03:30:00 3.1 1 6.1 0.4 3.4 1 6.8 0.7 2.5 0.9 4.6 0.7 92 15 101 255 11.7 0 11.9 11.7 08/02/2005 03:40:00 4.5 1 7.2 1.5 4.5 1 6.8 1.9 3.4 1.1 6.5 0.7 95 17 90 255 11.7 0 11.7 11.7 08/02/2005 03:50:00 4.7 1.1 7.2 1.9 4.7 1.1 7.2 1.5 3.5 1.1 7.2 0.7 100 16 119 255 11.7 0 11.7 11.7 08/02/2005 04:00:00 4.1 1 6.5 1.1 4 1 6.5 1.1 3.1 0.8 5.7 1.1 104 15 116 255 11.6 0 11.7 11.7 08/02/2005 04:10:00 3.8 1 6.5 0.7 3.8 1.1 6.5 1.1 2.8 1 5.7 0.7 111 19 142 255 11.6 0 11.7 11.7 08/02/2005 04:20:00 3.4 1.1 6.5 0.7 3.4 1.1 6.1 0.4 2.5 1 4.6 0.4 100 17 106 255 11.6 0 11.7 11.4 08/02/2005 04:30:00 4.3 0.8 6.8 1.9 4.1 0.8 6.8 1.9 3.5 0.9 6.1 1.1 100 15 118 255 11.8 0 11.9 11.7 08/02/2005 04:40:00 4.3 1 7.2 1.9 4.2 1 7.2 1.9 3.3 1.1 5.7 0.4 106 16 102 255 11.9 0 11.9 11.9 08/02/2005 04:50:00 4.3 1 7.2 1.5 4.2 1 6.8 1.9 3.4 1 6.1 0.7 107 17 90 255 11.9 0 12.2 11.7 08/02/2005 05:00:00 4.5 1.1 7.2 1.1 4.4 1.2 7.6 1.1 3.5 1 5.7 1.1 113 15 125 255 11.8 0 11.9 11.7 08/02/2005 05:10:00 4.5 1 8 1.5 4.4 1 8 1.1 3.7 1 6.8 1.1 103 15 65 255 11.9 0 11.9 11.9 08/02/2005 05:20:00 4.7 0.9 6.8 2.6 4.5 0.9 6.8 2.3 3.8 1 6.5 1.5 111 15 109 255 11.9 0 11.9 11.7 08/02/2005 05:30:00 4.6 1 6.8 2.6 4.5 1 6.8 2.3 3.8 1 7.2 1.5 110 13 119 255 11.9 0 11.9 11.7 08/02/2005 05:40:00 4.2 0.8 6.1 2.6 4.1 0.8 5.7 2.3 3.2 0.8 5.3 1.5 113 14 99 255 12 0 11.9 11.9 08/02/2005 05:50:00 4.1 0.8 6.1 1.5 4 0.9 6.1 1.1 3.1 0.9 5.3 1.1 109 13 112 255 12.1 0 12.2 11.9 08/02/2005 06:00:00 3.6 0.9 5.7 1.5 3.5 1 5.3 1.1 2.7 0.8 4.6 1.1 113 14 109 255 12.1 0 12.2 11.9 08/02/2005 06:10:00 3.9 0.9 6.1 1.9 3.8 0.9 5.7 1.5 3 0.8 5.3 1.1 115 15 108 255 12.1 0 12.2 11.9 08/02/2005 06:20:00 4.1 1 6.5 1.5 4 0.9 6.1 1.9 3.1 0.9 6.5 1.1 110 13 115 255 12.3 0 12.5 12.2 08/02/2005 06:30:00 4.1 1 6.1 1.9 4 0.9 6.1 1.5 3.2 1 6.1 1.1 106 13 101 255 12.3 0 12.5 12.2 08/02/2005 06:40:00 3.3 0.9 5.7 0.7 3.2 1 5.7 0.7 2.4 0.9 4.6 0.4 99 18 103 255 12.3 0 12.5 12.2 08/02/2005 06:50:00 3.9 1 6.1 1.1 3.8 1 6.1 1.5 3 1 4.9 0.7 95 15 105 255 12.4 0 12.5 12.5 08/02/2005 07:00:00 3.6 0.8 5.7 1.5 3.5 0.8 5.3 1.5 2.8 0.8 4.9 0.7 103 14 100 255 12.5 0 12.5 12.5 08/02/2005 07:10:00 3.3 0.8 4.9 1.1 3.2 0.8 4.6 0.4 2.4 0.7 4.2 0.4 108 14 115 255 12.4 0 12.5 12.5 08/02/2005 07:20:00 3.8 0.9 6.1 1.9 3.7 0.9 6.1 1.5 3 0.8 5.3 1.5 115 13 119 255 12.5 0 12.7 12.5 08/02/2005 07:30:00 3.7 1 5.3 0.7 3.5 1 5.3 1.1 2.8 1 4.9 0.7 102 17 108 255 12.7 0 13 12.5 08/02/2005 07:40:00 3 1 4.9 0.4 2.9 1 4.9 0.4 2.3 0.9 4.6 0.4 103 15 99 255 13.1 0 13.3 12.7 08/02/2005 07:50:00 3.7 0.8 5.7 1.9 3.6 0.8 6.1 1.9 2.9 0.8 4.9 1.1 111 14 111 255 13.3 0 13.5 13.3 08/02/2005 08:00:00 3.7 0.9 5.7 1.1 3.6 0.9 5.7 1.1 3.1 0.9 5.7 0.7 101 13 93 255 13.8 0.2 14.4 13.3 08/02/2005 08:10:00 4.1 0.9 6.1 2.3 4 1 6.1 1.9 3.4 1 5.7 1.1 101 17 112 255 14.5 0.1 15.2 14.4 08/02/2005 08:20:00 3.6 0.9 5.7 0.7 3.6 0.9 5.7 1.1 2.9 0.8 4.9 0.7 92 20 106 255 15.2 0.3 16.3 14.6 08/02/2005 08:30:00 4 0.9 6.1 1.5 3.9 0.9 6.1 1.5 3.4 0.8 5.7 1.1 101 16 130 255 15.6 0.1 16.3 15.5 08/02/2005 08:40:00 3.5 1.1 5.7 1.1 3.5 1.1 6.1 0.4 3.1 1.1 6.1 0.4 84 17 92 255 16.1 0 16.6 16 08/02/2005 08:50:00 3.2 1.1 6.1 0.4 3.2 1.1 6.1 0.4 2.7 1 5.7 0.4 94 23 116 255 16.2 0.2 16.8 15.7 08/02/2005 09:00:00 4.1 1 6.5 1.5 4.1 1 6.8 1.5 3.5 0.9 6.1 1.5 83 17 80 255 15.6 0 16.3 15.5 08/02/2005 09:10:00 4 1 6.5 1.1 3.9 1 6.1 1.1 3.4 1 5.3 1.1 89 14 92 255 15.7 0 16.3 15.5 08/02/2005 09:20:00 3.8 1.1 6.8 1.5 3.8 1.1 6.5 1.5 3.4 1.2 6.5 0.7 79 19 71 255 16.8 0.5 17.7 16 08/02/2005 09:30:00 4.2 0.8 5.7 2.3 4.2 0.8 6.1 2.3 3.3 0.9 5.3 1.1 74 21 91 255 17.5 0.1 17.7 17.1 08/02/2005 09:40:00 3.7 0.8 5.7 1.5 3.7 0.8 5.7 1.9 3.1 0.9 5.3 0.7 74 15 76 255 16.8 0.2 17.4 16.6 08/02/2005 09:50:00 3.6 0.8 5.7 1.9 3.6 0.8 6.1 1.9 2.8 0.8 4.9 0.7 65 20 87 255 16.7 0 17.1 16.6 08/02/2005 10:00:00 3.2 0.8 5.3 0.7 3.1 0.8 4.9 1.1 2.7 0.8 4.9 0.7 57 17 59 255 16.6 0.2 17.4 16.3 08/02/2005 10:10:00 3.8 1.1 6.5 1.5 3.7 1.1 6.5 1.5 3.2 1 6.1 1.1 77 18 79 255 16.1 0 16.6 16 08/02/2005 10:20:00 3.5 0.9 5.3 0.7 3.5 0.9 5.7 1.1 3 0.9 4.9 1.1 65 16 74 255 16.1 0 16.8 16 08/02/2005 10:30:00 3.4 1 6.8 1.5 3.4 1.1 6.5 1.1 3 1 5.7 1.1 56 17 22 255 16.5 0 16.8 16.3 08/02/2005 10:40:00 4 1.4 7.6 1.9 4 1.4 7.6 1.5 3.5 1.2 6.5 0.7 43 17 34 255 16.8 0.1 17.4 16.8 08/02/2005 10:50:00 4.3 1.6 9.5 1.1 4.3 1.7 9.5 0.7 3.7 1.3 8.8 1.1 40 18 10 255 17.4 0.2 18 16.8 08/02/2005 11:00:00 6.5 1 9.5 3.4 6.5 1.1 9.5 3.4 5.5 1.1 8 2.6 38 14 25 255 17.8 0 18.2 17.4 08/02/2005 11:10:00 6.1 1.1 8.8 3 6 1.1 9.1 3 5.3 1.2 8 1.9 29 13 34 255 17.8 0 18.2 17.4 08/02/2005 11:20:00 5.3 1 8.4 3 5.3 1 8.8 3 4.3 1 6.5 1.5 38 15 60 255 17.5 0.1 18 17.1 08/02/2005 11:30:00 5.8 1.2 8.8 2.6 5.8 1.2 9.5 3 4.8 1.2 8.4 1.9 44 18 32 255 17.8 0 18 17.4 08/02/2005 11:40:00 4.9 1.1 7.6 1.9 5 1.1 7.6 1.9 4 1 6.5 1.9 43 19 29 255 17.8 0 18 17.4 08/02/2005 11:50:00 6.3 1.2 8.8 3.8 6.3 1.2 8.8 3.8 5.3 1.3 8.4 1.9 35 14 45 255 17.5 0 17.7 17.1 08/02/2005 12:00:00 5.3 1.2 8 2.3 5.4 1.2 8.8 2.3 4.6 1.2 7.6 1.9 36 15 31 255 18.3 0.4 18.8 17.4 08/02/2005 12:10:00 6.3 1.6 10.7 0.7 6.3 1.5 10.7 1.1 5.2 1.7 9.9 1.1 30 20 30 255 18.9 0 19.1 18.8 08/02/2005 12:20:00 5.2 1.3 8.4 1.5 5.3 1.3 8.4 1.5 4.2 1.4 8.4 0.7 29 21 55 255 19 0 19.1 18.8 08/02/2005 12:30:00 6 1.2 8.8 3 6.1 1.2 8.8 3.4 5.1 1.2 8.8 1.1 36 17 21 255 18.5 0.2 19.1 18 08/02/2005 12:40:00 5.4 1.4 8.4 1.9 5.4 1.4 8.8 1.9 4.7 1.5 8.8 1.5 36 17 17 255 18.2 0.1 18.8 18 08/02/2005 12:50:00 4.7 1.3 8 1.1 4.8 1.3 8 1.1 4 1.4 7.2 0.4 31 16 39 255 18.7 0 19.1 18.2 08/02/2005 13:00:00 4.2 1.2 6.8 1.1 4.2 1.2 6.8 1.5 2.9 1.1 6.5 0.7 13 20 9 255 18.7 0 19.4 18.2 08/02/2005 13:10:00 5.2 1.2 8.8 1.5 5.3 1.2 9.1 2.3 3.8 1.3 7.6 0.4 11 18 10 255 19.2 0.4 20.5 18.8 08/02/2005 13:20:00 6.2 1.1 9.5 3.4 6.2 1.2 9.9 3 4.4 1.4 7.6 1.1 7 17 349 255 20.3 0 20.8 20 08/02/2005 13:30:00 5.5 1.3 9.1 2.3 5.6 1.3 9.1 2.3 3.7 1.4 7.2 0.7 3 16 331 255 20.5 0 20.8 20.3 08/02/2005 13:40:00 5.2 1.1 7.2 1.9 5.3 1.1 7.6 1.9 3.9 1.3 7.2 1.1 21 20 58 255 20.5 0 21.1 20.5 08/02/2005 13:50:00 6.6 1.3 9.1 3.8 6.7 1.3 9.5 3.8 4.7 1.6 8.8 0.4 9 14 26 255 20.3 0 20.5 20 08/02/2005 14:00:00 5.1 1.1 8 1.5 5.2 1 8 1.1 4 1.3 7.6 1.5 17 16 15 255 19.7 0.2 20 19.4 08/02/2005 14:10:00 6.4 1.1 10.7 3.4 6.5 1.1 10.7 3.4 4.9 1.5 8.4 1.9 16 15 16 255 19 0 19.4 18.8 08/02/2005 14:20:00 6.8 1.1 10.3 3.8 6.9 1.1 10.3 3.8 5.3 1.5 9.9 1.9 16 15 15 255 18.5 0.2 19.1 18 08/02/2005 14:30:00 5.8 1.5 9.1 2.3 5.9 1.5 9.9 3 4.3 1.7 8.8 1.1 13 16 38 255 18.1 0.1 18.8 17.7 08/02/2005 14:40:00 7.2 1.2 10.7 4.2 7.2 1.2 10.7 4.2 5.5 1.6 9.5 1.5 21 17 9 255 18 0.2 18.5 17.7 08/02/2005 14:50:00 7.8 1.3 11.1 4.2 7.8 1.3 10.7 4.6 6.2 1.6 9.9 2.6 17 13 45 255 18 0.1 18.2 18 08/02/2005 15:00:00 7.3 1.2 9.9 3.8 7.4 1.2 9.9 3.8 5.9 1.3 8.8 2.3 19 11 21 255 18 0 18.5 18 08/02/2005 15:10:00 7 1.3 9.9 3.4 7.1 1.3 9.9 3 5.4 1.6 9.5 1.1 12 12 22 255 18.2 0 18.5 17.7 08/02/2005 15:20:00 6.4 1.3 9.9 2.3 6.5 1.3 10.3 2.6 4.6 1.7 9.9 1.1 10 14 16 255 17.5 0.2 18.2 17.1 08/02/2005 15:30:00 6.7 1.3 9.9 3.8 6.8 1.3 9.9 3.8 5 1.7 8.8 1.5 13 13 17 255 17.3 0 17.4 17.1 08/02/2005 15:40:00 7.4 1.3 10.7 4.2 7.5 1.3 10.7 4.2 5.8 1.5 9.5 1.9 17 12 0 255 17.1 0 17.1 16.8 08/02/2005 15:50:00 6.7 1.1 9.1 2.6 6.8 1 9.1 3.4 5.3 1.3 8.8 1.9 19 11 27 255 16.8 0 17.1 16.8 08/02/2005 16:00:00 6.2 1.3 8.8 3 6.3 1.3 8.8 3 4.6 1.5 8.4 1.5 16 13 4 255 16.7 0 16.8 16.6 08/02/2005 16:10:00 6.8 1.2 10.3 3 6.8 1.2 10.3 3.8 5.4 1.6 9.1 1.9 20 13 27 255 16.6 0 16.8 16.6 08/02/2005 16:20:00 5.5 1.2 8.4 1.9 5.6 1.2 8.8 2.6 3.9 1.3 7.6 1.1 9 17 12 255 16.6 0 16.8 16.6 08/02/2005 16:30:00 6.4 1.3 9.9 3 6.4 1.3 10.3 3 4.3 1.5 8 1.1 6 15 350 255 16.7 0 16.8 16.6 08/02/2005 16:40:00 5.9 1.5 9.5 1.5 6 1.5 9.5 1.9 4.4 1.7 9.5 1.1 16 15 8 255 16.8 0 17.1 16.8 08/02/2005 16:50:00 6.9 1.6 12.2 3 7 1.7 12.2 3.4 5.1 1.8 11.1 1.5 12 17 23 255 16.7 0 17.1 16.6 08/02/2005 17:00:00 5.3 1.6 10.3 1.1 5.3 1.6 9.5 1.9 4.1 1.7 8.4 0.7 11 17 30 255 16.6 0 16.8 16.3 08/02/2005 17:10:00 3.8 0.8 6.1 1.1 3.9 0.9 6.1 1.1 3.2 0.9 5.3 1.1 24 16 28 255 16.4 0.1 16.8 16.3 08/02/2005 17:20:00 3.3 1.4 6.5 0.4 3.6 1.2 6.8 0.4 2.9 1.1 5.3 0.4 49 23 9 255 16.3 0.1 16.8 16.3 08/02/2005 17:30:00 3.5 1.3 8 0.4 3.7 1.3 7.6 1.1 3 1 6.8 1.1 65 21 58 255 16.2 0 16.8 16.3 08/02/2005 17:40:00 4.8 1.3 8.4 1.9 4.9 1.3 8.4 2.3 4.2 1.3 7.6 1.1 57 18 52 255 16.1 0 16.8 16 08/02/2005 17:50:00 4.1 1.2 8 1.1 4.2 1.2 7.6 1.1 3.6 0.9 7.2 1.9 56 20 42 255 15.9 0 16.3 15.7 08/02/2005 18:00:00 4 1.5 7.2 0.4 4.2 1.3 7.6 0.7 3.4 1.2 6.1 1.1 56 15 68 255 15.8 0 16.3 15.7 08/02/2005 18:10:00 6.1 1.4 9.5 3 6.2 1.3 9.5 3.4 4.9 1.4 8.4 1.9 52 14 54 255 15.7 0 16 15.5 08/02/2005 18:20:00 6.2 1.1 9.1 3.4 6.3 1.1 9.5 3.4 4.9 1.2 8.8 1.1 51 15 43 255 15.5 0 16 15.5 08/02/2005 18:30:00 7.3 1.8 11.5 2.6 7.4 1.7 12.2 3.4 6.3 1.6 10.7 2.6 49 15 49 255 15.6 0 16.3 15.5 08/02/2005 18:40:00 6.5 1.6 11.5 2.6 6.5 1.5 11.8 3.4 5.4 1.5 9.5 2.3 46 14 43 255 15.5 0 16.3 15.5 08/02/2005 18:50:00 6.9 1.7 11.1 3 6.9 1.7 11.5 3.4 5.7 1.7 9.9 2.3 48 17 45 255 15.2 0.1 15.7 15.2 08/02/2005 19:00:00 7.2 1.5 10.7 3 7.3 1.5 11.1 3.8 5.8 1.8 10.3 1.9 52 17 42 255 15.1 0.1 15.7 15.2 08/02/2005 19:10:00 6.4 1.5 9.9 1.5 6.5 1.4 9.5 2.6 5.1 1.5 9.1 1.9 50 16 32 255 15.1 0.1 15.7 15.2 08/02/2005 19:20:00 5.9 1.2 9.9 2.6 6 1.2 10.3 3 5.1 1.3 9.1 2.3 54 17 37 255 15 0 15.5 14.9 08/02/2005 19:30:00 6.4 1.5 9.9 3 6.4 1.5 9.9 2.6 5.1 1.5 8.4 2.3 49 16 48 255 14.8 0 15.5 14.9 08/02/2005 19:40:00 7.1 1.5 9.9 3 7.1 1.5 10.3 3 5.8 1.6 9.5 2.6 44 12 46 255 14.9 0 15.2 14.9 08/02/2005 19:50:00 6.9 1 9.1 4.9 6.9 1 9.1 4.2 5.8 1.3 9.5 3 43 13 37 255 15 0 15.2 14.9 08/02/2005 20:00:00 6.3 1.3 9.5 3 6.2 1.3 9.1 3 5.2 1.3 8.4 1.9 46 14 42 255 15 0 15.2 14.9 08/02/2005 20:10:00 4.8 0.9 7.2 2.3 4.8 0.9 6.8 2.6 3.9 1 6.5 1.1 60 17 70 255 14.8 0 15.2 14.6 08/02/2005 20:20:00 5.5 1.1 8.4 3 5.5 1.1 8.8 2.6 4.4 1.1 8 2.3 50 14 49 255 14.6 0 14.9 14.4 08/02/2005 20:30:00 4.9 1.3 8.4 1.9 4.9 1.3 8.4 1.9 3.9 1.2 6.5 1.5 58 17 25 255 14.2 0 14.6 14.1 08/02/2005 20:40:00 5.3 1.1 9.1 2.3 5.3 1.1 9.1 2.6 4.3 1 7.2 2.3 52 16 58 255 14.2 0 14.6 14.1 08/02/2005 20:50:00 4.9 1.2 9.1 2.6 4.9 1.2 9.1 2.6 4 1.2 7.2 1.5 55 17 42 255 14.2 0 14.6 14.1 08/02/2005 21:00:00 4.8 1.1 8 1.9 4.8 1.1 7.6 2.6 3.9 1.1 6.5 1.5 50 15 71 255 14.2 0 14.6 14.1 08/02/2005 21:10:00 5 0.9 7.2 2.3 5 0.9 7.2 2.6 3.9 1 6.5 1.9 52 14 35 255 14.1 0 14.6 14.1 08/02/2005 21:20:00 5.3 1.2 8.4 2.3 5.3 1.2 8.8 2.6 4.1 1.1 8.4 1.9 49 17 45 255 14.1 0 14.6 13.8 08/02/2005 21:30:00 5.5 1.1 8.4 3 5.5 1.1 8 3 4.5 1.1 7.6 1.9 41 15 34 255 14.1 0 14.6 14.1 08/02/2005 21:40:00 5.2 1 8.4 2.6 5.2 1.1 8.8 2.6 4.2 1 6.8 2.3 45 15 37 255 14.1 0 14.6 13.8 08/02/2005 21:50:00 6.2 1.1 8.4 3 6.1 1.2 8.4 3 5.2 1.1 7.6 2.3 44 14 45 255 13.9 0 14.6 13.8 08/02/2005 22:00:00 5.7 1.2 9.1 3 5.7 1.2 8.4 2.6 4.6 1.1 7.6 2.3 48 15 42 255 13.9 0 14.4 13.8 08/02/2005 22:10:00 6.1 1.7 10.7 2.6 6.2 1.7 10.7 2.6 4.9 1.7 9.5 1.9 50 15 40 255 13.9 0 14.4 13.5 08/02/2005 22:20:00 5.1 1.1 8 2.3 5.2 1.1 8.4 2.6 4.1 1.1 7.6 1.9 57 17 34 255 13.8 0 14.1 13.5 08/02/2005 22:30:00 4.6 1.2 7.6 1.5 4.7 1.2 7.6 1.9 3.6 1.1 6.8 1.5 72 17 63 255 13.3 0 13.8 13 08/02/2005 22:40:00 5.7 1.6 9.9 1.9 5.8 1.5 10.3 1.9 4.9 1.4 9.5 1.5 66 17 52 255 13.2 0.1 13.8 13 08/02/2005 22:50:00 5.3 1.1 8 2.6 5.4 1.1 8.8 3 4.4 1 7.2 1.9 61 17 60 255 13.5 0 14.1 13.3 08/02/2005 23:00:00 4.4 1 6.8 1.1 4.6 1 7.2 2.3 3.6 1 6.5 0.4 64 15 48 255 13.3 0 13.5 13 08/02/2005 23:10:00 3.9 1 6.5 1.1 4 1 6.1 1.5 3.1 1 6.1 0.7 66 17 48 255 12.9 0.1 13.3 12.7 08/02/2005 23:20:00 4.4 1.2 8 0.7 4.6 1.2 8 1.1 3.6 1.2 6.5 0.4 63 18 48 255 12.9 0 13 12.7 08/02/2005 23:30:00 4.8 1.1 7.6 2.3 4.8 1.1 8 2.3 3.9 1 6.1 1.1 58 16 58 255 12.9 0 13.3 12.7 08/02/2005 23:40:00 4.2 1.1 7.2 1.5 4.3 1.1 7.2 1.5 3.5 1.2 6.8 1.1 63 16 52 255 12.8 0 13 12.7 08/02/2005 23:50:00 4.1 0.8 6.5 2.3 4.2 0.8 6.5 2.3 3.3 0.9 5.7 1.1 76 13 74 255 12.7 0 12.7 12.5 08/03/2005 00:00:00 4.5 1 7.2 2.3 4.5 1 7.6 2.3 3.6 1.1 6.8 0.7 69 14 68 255 12.6 0 12.7 12.5 08/03/2005 00:10:00 4.1 0.8 5.7 1.9 4.2 0.8 6.1 1.9 3.2 0.8 5.3 1.1 86 13 65 255 12.5 0 12.7 12.5 08/03/2005 00:20:00 4.1 0.8 6.8 1.9 4.2 0.8 6.8 2.3 3.1 0.8 4.9 1.1 92 13 92 255 12.5 0 12.7 12.5 08/03/2005 00:30:00 4.5 0.8 6.1 2.3 4.6 0.7 6.1 2.6 3.4 0.8 5.3 1.5 89 11 101 255 12.8 0 13 12.7 08/03/2005 00:40:00 3.2 0.8 5.3 1.1 3.3 0.7 5.7 1.5 2.3 0.7 4.6 0.4 81 12 73 255 12.8 0 13 12.7 08/03/2005 00:50:00 1.8 0.9 3.8 0.4 2 0.9 3.8 0.4 1.3 0.9 3.8 0.4 93 16 79 255 12.5 0.1 12.7 12.2 08/03/2005 01:00:00 1.7 0.9 3.4 0.4 1.9 0.8 3.8 0.4 1.4 0.7 3 0.4 76 27 40 255 12.1 0 12.5 11.9 08/03/2005 01:10:00 2.9 0.6 4.6 1.5 2.9 0.7 4.6 1.1 2.1 0.7 4.2 0.4 70 15 77 255 11.8 0 11.9 11.7 08/03/2005 01:20:00 3 0.7 5.3 1.1 3.2 0.7 5.7 1.5 2.1 0.8 3.8 0.4 68 16 62 255 11.7 0 11.7 11.7 08/03/2005 01:30:00 3.9 0.9 6.1 1.9 4 0.9 6.1 2.3 3.1 0.8 5.3 1.1 60 15 69 255 12 0.1 12.5 11.7 08/03/2005 01:40:00 3.7 1 6.5 1.1 3.7 1 6.5 1.5 2.7 0.9 5.3 0.4 66 15 43 255 12.4 0 12.5 12.2 08/03/2005 01:50:00 4.2 1 6.8 1.9 4.3 1 6.8 1.9 3.4 1 6.1 1.5 67 18 61 255 12.7 0 12.7 12.5 08/03/2005 02:00:00 3.6 0.8 5.3 1.5 3.7 0.8 5.3 1.9 2.7 0.8 4.9 0.4 70 13 51 255 12.7 0 12.7 12.7 08/03/2005 02:10:00 4 1 6.5 1.5 4.1 1 6.5 1.5 3.2 1.2 6.1 0.4 70 17 44 255 12.6 0 12.7 12.5 08/03/2005 02:20:00 3.7 0.8 6.5 2.3 3.8 0.9 6.1 1.9 2.8 1 5.3 0.4 82 16 46 255 12.4 0 12.5 12.2 08/03/2005 02:30:00 4.4 0.9 6.8 2.3 4.3 0.9 6.5 2.3 3.3 1 6.1 1.1 52 15 40 255 12.3 0 12.5 12.2 08/03/2005 02:40:00 4.1 0.8 6.8 2.3 4.1 0.8 6.8 1.9 3.1 0.8 5.7 1.1 60 15 59 255 12.4 0 12.5 12.2 08/03/2005 02:50:00 3.1 0.8 5.3 0.7 3.2 0.8 5.7 0.7 2.1 0.8 4.6 0.4 70 15 85 255 12.3 0 12.5 12.2 08/03/2005 03:00:00 2.9 1.2 6.1 0.4 3 1.2 6.5 0.4 2 1.2 4.9 0.4 60 15 65 255 12.3 0 12.2 12.2 08/03/2005 03:10:00 3.2 1 5.3 0.4 3.3 1.1 5.3 0.4 2.5 1 4.6 0.4 57 16 73 255 12.3 0 12.2 12.2 08/03/2005 03:20:00 3.8 1 6.5 1.5 3.9 1 6.5 1.9 3 0.9 5.7 0.7 55 13 48 255 12.1 0 12.2 11.9 08/03/2005 03:30:00 5 1.2 8.4 2.3 4.9 1.2 8 2.3 3.5 1.3 8 0.4 50 14 43 255 12 0 12.2 11.9 08/03/2005 03:40:00 5.2 1 8 2.6 5.2 1.1 8 2.3 4 1.1 7.2 1.9 54 16 35 255 12.3 0 12.5 12.2 08/03/2005 03:50:00 4.9 1.1 7.6 2.3 5 1.1 8 1.5 3.8 1 6.8 1.1 55 15 44 255 12.4 0 12.5 12.2 08/03/2005 04:00:00 4 1 6.8 2.3 4 1.1 6.5 1.5 2.9 1.2 6.1 0.4 66 17 83 255 12.2 0 12.2 11.9 08/03/2005 04:10:00 4.3 0.9 6.8 2.3 4.4 1 7.2 1.9 3.2 1.1 6.5 0.4 67 14 63 255 12 0 12.2 11.9 08/03/2005 04:20:00 4.2 1 6.5 1.9 4.2 1 6.8 1.9 3.1 1.3 6.5 0.4 78 14 69 255 11.9 0 11.9 11.7 08/03/2005 04:30:00 4.6 0.9 6.5 2.3 4.6 0.9 6.8 2.6 3.2 1 6.1 1.1 76 13 64 255 12.1 0 12.2 11.9 08/03/2005 04:40:00 3.7 1 6.1 1.9 3.7 1 6.1 1.5 2.7 0.9 4.9 0.7 81 15 73 255 12.3 0 12.5 12.2 08/03/2005 04:50:00 3.5 1 5.3 1.1 3.5 1 5.3 1.5 2.2 0.9 4.6 0.4 92 17 86 255 12.3 0 12.5 11.9 08/03/2005 05:00:00 3.8 0.7 5.7 2.3 3.8 0.7 5.7 2.3 2.5 0.7 4.2 0.7 83 15 25 255 12 0 12.2 11.9 08/03/2005 05:10:00 4.1 0.6 5.7 2.6 4.2 0.6 5.3 3 2.9 0.7 4.9 1.1 88 12 81 255 11.8 0 11.9 11.7 08/03/2005 05:20:00 4 0.7 5.7 2.3 4.1 0.7 6.1 2.3 3 0.8 5.3 1.1 72 12 75 255 12.2 0 12.5 11.9 08/03/2005 05:30:00 3.6 0.9 6.1 0.4 3.7 0.9 6.1 0.7 2.6 1 4.9 0.4 67 15 65 255 12.6 0 12.7 12.5 08/03/2005 05:40:00 3.8 1 6.5 1.1 3.9 1 6.5 1.5 2.9 1 5.3 0.4 60 16 74 255 12.9 0 13 12.7 08/03/2005 05:50:00 4.2 1 6.5 1.9 4.2 1 6.8 1.9 3.2 1 5.7 1.1 51 12 30 255 13.1 0 13.3 13 08/03/2005 06:00:00 3.4 0.7 4.9 0.7 3.5 0.7 5.3 1.5 2.7 0.7 4.2 0.4 57 14 46 255 13.1 0 13.3 13 08/03/2005 06:10:00 3.7 1.2 6.1 0.7 3.7 1.2 6.1 0.7 2.8 1.2 5.3 0.4 42 12 39 255 13.2 0 13.3 13 08/03/2005 06:20:00 2 0.7 4.2 0.4 2.1 0.7 4.6 0.7 1.3 0.7 3.8 0.4 54 14 47 255 13.3 0 13.3 13.3 08/03/2005 06:30:00 2.5 0.6 3.8 0.7 2.6 0.6 4.2 0.7 1.7 0.8 3.8 0.4 69 17 40 255 13.3 0 13.5 13.3 08/03/2005 06:40:00 2.4 0.7 3.8 0.4 2.5 0.6 3.8 1.1 1.7 0.6 3.4 0.4 79 17 58 255 13.3 0 13.3 13 08/03/2005 06:50:00 3.2 0.8 4.9 1.1 3.2 0.8 4.6 1.1 2 0.8 3.8 0.4 56 14 51 255 13.2 0 13.3 13 08/03/2005 07:00:00 3.3 1 6.1 0.4 3.3 1 6.1 0.7 2.3 1 5.3 0.4 51 15 47 255 13.5 0 13.5 13.3 08/03/2005 07:10:00 3.3 0.8 5.7 1.5 3.3 0.8 5.3 1.5 2.4 0.8 4.9 0.4 47 14 38 255 13.7 0 13.8 13.5 08/03/2005 07:20:00 2.6 0.6 4.2 0.7 2.5 0.6 4.2 1.1 1.6 0.6 3 0.4 61 17 63 255 13.7 0 13.8 13.5 08/03/2005 07:30:00 2.9 0.7 4.6 1.1 2.9 0.8 4.6 1.1 2.1 0.7 3.8 0.4 64 13 60 255 13.6 0 14.1 13.5 08/03/2005 07:40:00 3.1 0.7 5.3 1.5 3 0.7 5.3 1.5 2.2 0.7 4.2 0.4 52 15 59 255 13.5 0 13.5 13.5 08/03/2005 07:50:00 3.1 0.7 5.3 1.5 3.1 0.7 5.3 1.5 2.2 0.8 4.9 0.4 55 17 49 255 13.4 0 13.5 13.3 08/03/2005 08:00:00 2.4 0.6 4.2 0.7 2.4 0.6 3.8 0.7 1.7 0.8 3.8 0.4 60 19 52 255 13.2 0 13.3 13 08/03/2005 08:10:00 1.9 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.5 0.9 3.8 0.4 63 18 52 255 13.1 0 13.3 12.7 08/03/2005 08:20:00 2.6 0.8 4.6 0.7 2.6 0.8 4.9 0.4 1.9 0.8 3.8 0.4 57 14 43 255 13 0 13 12.7 08/03/2005 08:30:00 2.5 0.6 3.8 1.1 2.5 0.6 4.2 1.1 2.1 0.6 3.8 0.7 53 15 79 255 13.2 0 13.3 13 08/03/2005 08:40:00 2.4 0.8 4.6 0.4 2.4 0.7 4.6 0.7 1.9 0.8 4.2 0.4 48 17 41 255 13.3 0 13.3 13 08/03/2005 08:50:00 3.3 1 5.3 1.1 3.3 1.1 5.7 1.1 2.5 1 4.9 0.4 59 15 49 255 13.3 0 13.3 13.3 08/03/2005 09:00:00 3.6 1 5.7 0.7 3.7 1 5.7 1.1 3.2 0.8 5.3 1.5 50 12 70 255 13.2 0 13.3 13 08/03/2005 09:10:00 2.6 0.8 4.6 1.1 2.7 0.9 4.9 0.7 2.2 1 4.2 0.4 45 15 46 255 13.1 0 13.3 13 08/03/2005 09:20:00 2.9 0.8 4.6 0.4 3 0.8 4.2 0.4 2.4 0.8 4.2 0.4 48 16 26 255 13.7 0.1 14.4 13.3 08/03/2005 09:30:00 2.9 0.7 4.2 0.7 3.1 0.7 4.6 0.7 2.5 0.7 4.2 0.4 42 12 35 255 14.2 0 14.6 13.8 08/03/2005 09:40:00 3.3 0.7 4.9 1.5 3.4 0.7 5.3 1.5 2.9 0.7 4.6 1.1 41 12 42 255 14.1 0 14.6 13.8 08/03/2005 09:50:00 3.7 0.6 4.9 1.9 3.7 0.6 4.9 1.9 3 0.8 4.6 1.1 43 13 37 255 13.9 0 14.4 13.8 08/03/2005 10:00:00 3.2 0.6 4.9 1.5 3.2 0.6 5.3 1.5 2.6 0.7 4.6 0.7 47 17 68 255 13.9 0 14.6 13.8 08/03/2005 10:10:00 3.2 0.9 6.1 0.7 3.3 0.9 5.3 1.1 2.8 0.8 4.9 1.1 45 15 73 255 14.2 0 14.9 13.8 08/03/2005 10:20:00 3.7 0.7 5.3 1.9 3.8 0.7 5.7 1.9 3.1 0.8 5.3 1.1 32 15 26 255 15 0.3 16 14.6 08/03/2005 10:30:00 4.3 0.8 6.8 2.3 4.4 0.8 6.8 2.3 3.1 1.1 5.7 0.4 13 13 7 255 15.9 0.3 16.8 15.5 08/03/2005 10:40:00 3.2 0.8 5.3 1.1 3.4 0.8 5.3 0.7 2 1 4.6 0.4 8 18 12 255 16.9 0.1 17.4 16.6 08/03/2005 10:50:00 2.9 0.9 5.3 0.7 3 0.9 4.9 0.4 2.1 1.1 5.3 0.4 15 20 18 255 16.9 0.1 17.4 16.8 08/03/2005 11:00:00 3.2 0.7 4.9 1.1 3.4 0.7 4.9 1.1 2.7 0.9 4.9 0.4 26 17 24 255 16.6 0.2 17.1 16.6 08/03/2005 11:10:00 3.8 1 6.1 1.5 3.9 1 6.1 1.5 3.1 1.1 6.1 0.4 24 19 15 255 16.5 0 16.8 16.3 08/03/2005 11:20:00 3.2 1 5.7 0.4 3.3 1 5.7 0.7 1.9 0.8 4.2 0.4 4 19 350 255 16.7 0 17.1 16.6 08/03/2005 11:30:00 2.7 0.7 4.6 0.7 2.9 0.7 4.6 0.7 2 0.7 3.8 0.4 15 13 37 255 16.8 0.3 17.7 16.3 08/03/2005 11:40:00 2 0.7 3.8 0.4 2.2 0.6 3.8 0.4 1.4 0.7 3.4 0.4 11 20 345 255 17.9 0 18.2 17.4 08/03/2005 11:50:00 2.2 0.9 3.8 0.4 2.3 0.9 3.8 0.4 1.4 0.8 3.4 0.4 358 15 340 255 17.9 0 18.2 17.7 08/03/2005 12:00:00 1.3 0.7 2.6 0.4 1.3 0.7 3 0.4 0.7 0.5 2.3 0.4 347 20 350 255 17.8 0.1 18.5 17.4 08/03/2005 12:10:00 3 1 5.3 0.4 3 1 5.3 0.4 2.3 0.9 4.6 0.4 28 21 34 255 18.2 0 18.5 18 08/03/2005 12:20:00 1.3 0.8 3.4 0.4 1.3 0.8 3.4 0.4 0.7 0.5 2.3 0.4 10 27 25 255 17.9 0 18.5 17.7 08/03/2005 12:30:00 0.8 0.5 2.6 0.4 1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 15 17 13 255 17.9 0.1 18.5 17.7 08/03/2005 12:40:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 38 22 16 255 17.9 0.1 18.5 17.7 08/03/2005 12:50:00 1.4 0.8 3.8 0.4 1.4 0.7 3.4 0.4 0.9 0.6 2.3 0.4 359 32 327 255 18.2 0.2 19.1 18 08/03/2005 13:00:00 2.4 0.7 4.2 0.7 2.3 0.8 4.2 0.4 1.4 0.8 3.4 0.4 2 19 13 255 19.1 0.2 20 18.5 08/03/2005 13:10:00 2.3 0.7 4.2 0.4 2.3 0.8 4.2 0.4 1.6 0.8 3.4 0.4 8 20 3 255 19.1 0.1 20 18.8 08/03/2005 13:20:00 1.2 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.6 0.4 2.3 0.4 359 30 339 255 18.9 0 19.4 18.5 08/03/2005 13:30:00 2.1 0.6 3.8 0.4 2.1 0.7 3.4 0.4 1.4 0.8 3.4 0.4 47 22 40 255 18.5 0.2 19.1 18.2 08/03/2005 13:40:00 2.8 0.7 4.6 1.5 2.8 0.7 4.6 1.5 1.9 1 4.2 0.4 16 14 18 255 18.5 0.1 19.1 18.2 08/03/2005 13:50:00 3 0.6 4.6 1.1 3.2 0.5 4.6 1.5 2.3 0.8 3.8 0.4 26 15 36 255 18.5 0 18.8 18.2 08/03/2005 14:00:00 3.1 0.6 4.6 1.5 3.3 0.6 4.9 1.9 2.1 0.9 3.8 0.4 16 17 25 255 18.5 0 18.5 18.2 08/03/2005 14:10:00 3.7 0.8 5.7 1.5 3.9 0.8 5.7 1.5 2.9 1.1 5.3 0.4 15 16 32 255 18.2 0 18.5 18 08/03/2005 14:20:00 3 0.9 4.9 0.7 3.3 0.8 5.3 1.5 2.1 1.2 4.9 0.4 17 17 24 255 18.2 0 18.5 18 08/03/2005 14:30:00 3.3 1 5.7 0.7 3.6 0.9 5.7 1.1 2.4 1 5.3 0.4 7 14 347 255 18.2 0 18.8 18 08/03/2005 14:40:00 2.6 1 5.3 0.4 2.9 1 5.3 0.7 1.6 1 4.6 0.4 7 18 22 255 18.5 0 19.1 18.2 08/03/2005 14:50:00 3 1.5 6.5 0.4 3.3 1.3 6.5 1.1 2 1.6 6.1 0.4 8 22 27 255 18.8 0.1 19.4 18.5 08/03/2005 15:00:00 4.3 0.8 6.1 2.3 4.5 0.8 6.1 2.6 3.1 1.1 5.7 0.4 16 15 35 255 19.1 0 19.4 18.8 08/03/2005 15:10:00 4.8 0.9 6.8 2.3 4.9 0.8 7.2 3 3.4 1.2 6.5 0.4 23 17 12 255 19.1 0 19.4 18.8 08/03/2005 15:20:00 4.3 0.9 6.5 1.9 4.4 0.9 7.2 2.3 3.5 1.1 6.1 0.4 27 18 19 255 18.4 0.1 18.8 18.2 08/03/2005 15:30:00 3.6 0.6 5.3 1.9 3.8 0.6 5.3 2.3 2.9 0.9 4.6 0.4 24 14 22 255 17.8 0 18.2 17.7 08/03/2005 15:40:00 3.2 0.8 5.3 1.1 3.5 0.7 5.3 1.9 2.3 1 4.6 0.4 31 19 8 255 17.7 0 17.7 17.4 08/03/2005 15:50:00 3.2 1 5.7 0.4 3.5 0.8 5.3 1.1 2.7 1 4.9 0.4 38 17 25 255 17.6 0 17.7 17.4 08/03/2005 16:00:00 3.4 1 5.7 1.1 3.6 1 5.7 1.1 3.1 1 6.1 0.7 43 17 25 255 18 0.1 18.2 17.7 08/03/2005 16:10:00 3.9 0.9 6.1 1.1 4.1 0.9 6.1 1.5 3.4 1 5.3 1.1 41 20 71 255 18.4 0 18.5 18.2 08/03/2005 16:20:00 4.5 1.1 6.8 1.1 4.6 1.1 7.2 1.9 3.8 1.1 6.8 1.5 43 19 12 255 18.2 0 18.5 18 08/03/2005 16:30:00 3.6 0.7 5.3 1.5 3.8 0.7 5.3 1.9 3 0.8 4.9 1.1 38 13 42 255 17.9 0 18 17.7 08/03/2005 16:40:00 3.4 0.6 4.9 1.9 3.6 0.6 4.9 2.3 2.6 0.7 4.6 1.1 39 13 44 255 17.8 0 18 17.4 08/03/2005 16:50:00 2.9 0.6 4.6 1.5 3.1 0.5 4.6 1.9 2.4 0.7 4.2 0.4 37 11 37 255 17.5 0 17.7 17.4 08/03/2005 17:00:00 2.4 0.8 3.8 0.4 2.7 0.7 4.2 1.1 2 0.8 3.4 0.4 39 13 39 255 17.6 0 17.7 17.4 08/03/2005 17:10:00 2.1 0.7 3.8 0.4 2.5 0.6 4.2 1.1 1.6 0.8 3.4 0.4 33 19 356 255 17.8 0 18 17.4 08/03/2005 17:20:00 2.8 0.5 3.8 0.7 2.7 0.5 3.8 1.1 1.7 0.8 3.4 0.4 346 14 317 255 17.8 0 18.2 17.7 08/03/2005 17:30:00 2 0.8 3.4 0.4 2.1 0.8 3.4 0.4 0.9 0.7 3 0.4 345 16 321 255 17.9 0 18.2 17.7 08/03/2005 17:40:00 2.5 0.8 4.6 1.1 2.7 0.7 4.6 1.1 1.5 0.9 4.2 0.4 353 15 336 255 18.2 0 18.2 18 08/03/2005 17:50:00 2 0.8 3.4 0.4 2.1 0.8 3.4 0.4 1.3 0.8 3.4 0.4 349 14 335 255 18.3 0 18.5 18.2 08/03/2005 18:00:00 2.3 0.5 3 0.7 2.6 0.4 3.4 1.1 1.4 0.7 3 0.4 357 8 0 255 18.5 0 18.5 18.2 08/03/2005 18:10:00 1.4 0.6 3 0.4 1.7 0.5 3.4 0.4 0.7 0.5 2.6 0.4 1 17 358 255 18.5 0 18.8 18.2 08/03/2005 18:20:00 0.8 0.6 2.6 0.4 1.1 0.6 3 0.4 0.6 0.5 3 0.4 7 22 352 255 18.6 0 18.8 18.5 08/03/2005 18:30:00 0.7 0.5 1.9 0.4 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 356 30 23 255 18.6 0 18.8 18.5 08/03/2005 18:40:00 0.7 0.5 1.9 0.4 0.9 0.6 2.3 0.4 0.5 0.3 1.9 0.4 324 22 298 255 18.3 0 18.5 18 08/03/2005 18:50:00 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 334 11 335 255 18.2 0 18.2 18 08/03/2005 19:00:00 0.6 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.5 0.4 332 21 2 255 18.1 0 18.2 18 08/03/2005 19:10:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 321 13 346 255 17.9 0 18 17.7 08/03/2005 19:20:00 1 0.5 2.3 0.4 1.2 0.6 2.6 0.4 0.7 0.4 1.9 0.4 323 9 313 255 17.7 0 18 17.4 08/03/2005 19:30:00 1.4 0.7 2.6 0.4 1.6 0.6 3 0.4 1 0.6 2.6 0.4 317 13 300 255 17.4 0 17.7 17.1 08/03/2005 19:40:00 1.4 0.6 2.6 0.4 1.6 0.5 2.6 0.4 0.9 0.6 2.6 0.4 312 17 296 255 17.2 0 17.4 16.8 08/03/2005 19:50:00 1.1 0.6 2.3 0.4 1.4 0.6 2.6 0.4 0.7 0.5 2.3 0.4 302 16 301 255 16.9 0 17.1 16.8 08/03/2005 20:00:00 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 328 29 25 255 16.6 0 16.8 16.6 08/03/2005 20:10:00 2.2 0.5 3 0.4 2.5 0.5 3.4 1.1 1.6 0.6 3 0.4 26 12 47 255 16.4 0.2 16.8 16.3 08/03/2005 20:20:00 1.1 0.6 2.3 0.4 1.6 0.5 2.6 0.4 0.5 0.3 2.3 0.4 18 7 8 255 16 0 16.8 15.7 08/03/2005 20:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 15 0 255 255 15.6 0 16 15.5 08/03/2005 20:40:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 351 20 343 255 15.2 0.1 15.5 14.9 08/03/2005 20:50:00 0.4 0.2 1.1 0.4 1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 305 10 308 255 14.8 0.1 15.2 14.6 08/03/2005 21:00:00 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 0.4 0.1 0.7 0.4 284 0 284 255 14.5 0 14.9 14.4 08/03/2005 21:10:00 0.4 0.1 1.1 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 53 69 85 255 14.2 0 14.6 13.8 08/03/2005 21:20:00 1.4 0.7 3.4 0.4 1.7 0.8 3.4 0.4 0.9 0.6 2.6 0.4 59 17 46 255 13.9 0 14.6 13.8 08/03/2005 21:30:00 0.9 0.5 2.3 0.4 1.3 0.6 2.6 0.4 0.6 0.4 2.3 0.4 67 17 78 255 13.7 0.1 14.4 13.5 08/03/2005 21:40:00 1.2 0.6 2.6 0.4 1.5 0.6 3 0.4 0.7 0.5 2.6 0.4 78 13 77 255 13.4 0 13.8 13.3 08/03/2005 21:50:00 0.5 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.1 1.1 0.4 62 10 73 255 13.1 0.2 13.5 12.7 08/03/2005 22:00:00 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 49 8 47 255 12.7 0.1 13.3 12.5 08/03/2005 22:10:00 0.4 0.3 1.5 0.4 0.6 0.5 1.9 0.4 0.4 0.1 1.1 0.4 49 15 34 255 12.4 0 12.7 12.2 08/03/2005 22:20:00 0.5 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.1 0.4 54 7 44 255 12.1 0 12.5 11.9 08/03/2005 22:30:00 0.8 0.5 2.3 0.4 1.3 0.5 2.6 0.4 0.5 0.3 1.5 0.4 56 11 47 255 12 0.1 12.5 11.9 08/03/2005 22:40:00 1.2 0.4 2.3 0.4 1.7 0.4 2.6 0.7 0.6 0.4 1.9 0.4 40 7 19 255 12 0 12.5 11.9 08/03/2005 22:50:00 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 48 7 45 255 11.7 0 12.2 11.7 08/03/2005 23:00:00 0.7 0.4 1.9 0.4 1 0.4 2.3 0.4 0.4 0.1 1.1 0.4 69 9 76 255 11.6 0 11.7 11.7 08/03/2005 23:10:00 1.1 0.5 2.3 0.4 1.3 0.5 2.6 0.4 0.5 0.3 1.5 0.4 81 8 74 255 11.5 0 11.7 11.4 08/03/2005 23:20:00 1.3 0.4 2.3 0.4 1.5 0.4 2.6 0.4 0.4 0.1 1.1 0.4 85 5 89 255 11.3 0 11.7 11.4 08/03/2005 23:30:00 0.9 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0.1 1.1 0.4 91 9 89 255 11.3 0 11.4 11.1 08/03/2005 23:40:00 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 101 11 117 255 11.3 0 11.4 11.1 08/03/2005 23:50:00 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 0.5 0.3 1.1 0.4 109 10 116 255 11.3 0 11.4 11.1 08/04/2005 00:00:00 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 0.4 0.2 1.5 0.4 112 12 108 255 11.3 0 11.4 11.1 08/04/2005 00:10:00 1.2 0.5 2.3 0.4 1.4 0.5 2.3 0.4 0.4 0.1 1.1 0.4 110 8 110 255 11.3 0 11.4 11.1 08/04/2005 00:20:00 0.4 0.1 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 102 23 112 255 11.3 0 11.4 11.1 08/04/2005 00:30:00 0.8 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.4 0 0.7 0.4 60 12 70 255 11.3 0 11.4 11.1 08/04/2005 00:40:00 0.9 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 86 7 81 255 11.2 0 11.4 11.1 08/04/2005 00:50:00 0.6 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.7 0.4 60 10 55 255 11.1 0 11.1 11.1 08/04/2005 01:00:00 1 0.5 1.9 0.4 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 76 15 76 255 11.1 0 11.4 11.1 08/04/2005 01:10:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 0.4 0.2 1.1 0.4 92 5 92 255 11.1 0 11.4 11.1 08/04/2005 01:20:00 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.3 1.5 0.4 87 5 86 255 11.1 0 11.1 11.1 08/04/2005 01:30:00 1.6 0.4 2.6 0.4 1.7 0.4 3 0.7 0.7 0.4 1.9 0.4 105 10 97 255 11.1 0 11.1 11.1 08/04/2005 01:40:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 83 18 113 255 11.3 0 11.4 11.1 08/04/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 29 255 255 11.3 0 11.4 11.4 08/04/2005 02:00:00 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.4 0.1 1.1 0.4 84 35 97 255 11.3 0 11.4 11.1 08/04/2005 02:10:00 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.5 0.3 1.9 0.4 86 14 102 255 11.3 0 11.4 11.1 08/04/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 255 255 11.3 0 11.4 11.4 08/04/2005 02:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 61 6 90 255 11.2 0 11.4 11.1 08/04/2005 02:40:00 1.5 0.7 4.2 0.4 1.6 0.8 4.2 0.4 0.8 0.5 3 0.4 98 12 125 255 11.1 0 11.4 11.1 08/04/2005 02:50:00 2.5 0.9 4.6 0.4 2.6 0.8 4.6 0.4 1.5 0.7 3.4 0.4 109 15 104 255 11.5 0.2 11.9 11.1 08/04/2005 03:00:00 3.2 0.8 4.9 0.4 3.3 0.8 4.9 1.1 2.6 0.8 4.6 0.4 100 13 111 255 12.3 0.1 12.7 11.9 08/04/2005 03:10:00 1.2 0.5 3 0.4 1.5 0.4 3 0.4 1 0.5 2.6 0.4 33 19 52 255 12.4 0 12.7 11.9 08/04/2005 03:20:00 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 54 4 51 255 11.9 0.1 12.2 11.7 08/04/2005 03:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 59 11 58 255 11.4 0 11.7 11.1 08/04/2005 03:40:00 0.7 0.6 3 0.4 0.8 0.6 2.3 0.4 0.5 0.4 2.3 0.4 106 12 124 255 11.1 0 11.1 10.9 08/04/2005 03:50:00 2.1 0.5 3.4 0.7 2.2 0.5 3.4 1.1 1.1 0.6 2.6 0.4 107 9 97 255 10.9 0 11.1 10.9 08/04/2005 04:00:00 2.5 0.6 3.4 0.7 2.6 0.6 3.8 0.7 1.6 0.6 3 0.4 108 10 113 255 10.9 0 11.1 10.9 08/04/2005 04:10:00 2.6 0.4 3.8 1.5 2.8 0.4 3.8 1.9 1.7 0.6 2.6 0.4 98 12 81 255 11.1 0 11.4 11.1 08/04/2005 04:20:00 2.2 0.5 3.8 0.7 2.4 0.5 3.8 1.5 1.5 0.5 2.6 0.4 88 9 78 255 11.3 0 11.7 11.1 08/04/2005 04:30:00 2.3 0.5 3.4 1.1 2.4 0.5 3.8 1.1 1.4 0.5 3 0.4 90 10 98 255 11.6 0 11.7 11.4 08/04/2005 04:40:00 2.7 0.6 4.2 1.5 2.9 0.5 4.2 1.9 1.9 0.6 3.4 0.4 90 9 93 255 11.7 0 11.9 11.7 08/04/2005 04:50:00 3.1 0.5 4.2 1.5 3.3 0.5 4.6 1.9 2.1 0.7 3.4 0.4 84 7 80 255 12 0 12.2 11.7 08/04/2005 05:00:00 2.6 0.6 4.2 1.1 2.8 0.6 4.6 0.7 1.7 0.7 3.4 0.4 83 10 69 255 12.1 0 12.2 11.9 08/04/2005 05:10:00 2.3 0.6 3.8 0.7 2.5 0.6 3.8 1.1 1.5 0.6 3.4 0.4 98 11 88 255 12.2 0 12.2 11.9 08/04/2005 05:20:00 2.5 0.6 3.8 0.7 2.6 0.6 4.2 0.7 1.6 0.7 3 0.4 110 11 105 255 12.3 0 12.5 12.2 08/04/2005 05:30:00 2.1 0.6 3.8 0.4 2.3 0.5 3.8 0.7 1.3 0.7 2.6 0.4 109 10 99 255 12.5 0 12.7 12.5 08/04/2005 05:40:00 2.4 0.6 3.4 0.7 2.5 0.5 3.8 1.1 1.5 0.6 3 0.4 101 10 94 255 12.7 0 12.7 12.5 08/04/2005 05:50:00 1.6 0.7 3 0.4 1.9 0.6 3.4 0.4 1 0.6 2.6 0.4 86 13 102 255 12.7 0 12.7 12.7 08/04/2005 06:00:00 2.5 0.5 3.8 1.1 2.7 0.6 4.2 1.1 1.7 0.5 3.4 0.4 80 10 77 255 12.8 0 12.7 12.7 08/04/2005 06:10:00 2.7 0.5 3.8 0.7 2.9 0.5 4.2 1.5 2 0.6 3.4 0.4 82 10 82 255 12.8 0 12.7 12.7 08/04/2005 06:20:00 2.9 0.5 4.2 1.5 3.1 0.5 4.2 1.5 2.2 0.5 3.4 0.7 86 8 92 255 12.8 0 13 12.7 08/04/2005 06:30:00 3.2 0.5 4.9 1.9 3.3 0.5 4.9 1.9 2.4 0.7 4.2 0.7 85 9 59 255 13 0 13.3 12.7 08/04/2005 06:40:00 2.4 0.6 4.2 0.7 2.6 0.6 4.2 1.1 1.7 0.6 3.4 0.4 93 10 96 255 13.3 0 13.3 13 08/04/2005 06:50:00 2.1 0.5 3.8 1.1 2.2 0.4 3.4 1.1 1.4 0.6 3 0.4 103 9 108 255 13.3 0 13.5 13.3 08/04/2005 07:00:00 1.8 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.1 0.6 2.6 0.4 99 11 94 255 13.5 0 13.8 13.3 08/04/2005 07:10:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.7 1.5 0.7 3 0.4 104 12 113 255 13.7 0 13.8 13.5 08/04/2005 07:20:00 2.2 0.8 4.2 0.4 2.2 0.8 3.8 0.4 1.6 0.7 3.4 0.4 107 15 100 255 13.7 0 13.8 13.5 08/04/2005 07:30:00 2.3 0.6 3.4 1.1 2.3 0.6 3.8 0.7 1.4 0.6 2.6 0.4 113 12 110 255 13.9 0 14.4 13.5 08/04/2005 07:40:00 1.6 0.7 3.4 0.4 1.8 0.6 3.4 0.4 1.2 0.6 3 0.4 111 14 112 255 14.1 0 14.4 13.8 08/04/2005 07:50:00 2.3 0.6 3.4 0.4 2.4 0.6 3.8 0.7 1.7 0.6 3.4 0.4 119 12 116 255 14.4 0 14.9 14.4 08/04/2005 08:00:00 2.3 0.8 3.8 0.4 2.5 0.7 3.8 0.4 1.8 0.7 3.4 0.4 118 13 124 255 14.6 0.1 15.2 14.6 08/04/2005 08:10:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.3 0.7 3 0.4 117 17 122 255 14.9 0.1 15.7 14.6 08/04/2005 08:20:00 1.5 0.8 3.4 0.4 1.7 0.7 3.8 0.4 1.2 0.7 3.4 0.4 99 27 99 255 15.5 0.2 16.3 15.2 08/04/2005 08:30:00 1.7 0.9 3.8 0.4 2 0.8 3.8 0.4 1.2 0.8 3 0.4 83 21 81 255 16.4 0.4 17.7 16 08/04/2005 08:40:00 1.9 0.8 3.8 0.4 2.1 0.8 4.2 0.4 1.5 0.9 3.4 0.4 73 22 52 255 17.8 0.4 18.5 17.1 08/04/2005 08:50:00 2.3 1 4.2 0.4 2.5 1 4.6 0.4 2 1 3.8 0.4 60 24 71 255 18 0 18.5 17.7 08/04/2005 09:00:00 2.1 0.6 3.4 0.4 2.3 0.6 3.8 0.4 1.8 0.7 3.4 0.4 49 21 42 255 18.8 0.2 19.4 18.2 08/04/2005 09:10:00 2.3 0.8 4.6 0.4 2.4 0.8 4.6 0.4 1.7 0.8 3.8 0.4 29 19 17 255 19.7 0.2 20.3 19.1 08/04/2005 09:20:00 2.6 0.8 5.3 0.4 2.7 0.8 4.6 0.7 2.2 1 4.9 0.4 22 22 43 255 19.8 0 20.3 19.7 08/04/2005 09:30:00 2.5 0.9 4.9 0.4 2.7 0.8 4.6 0.4 2.2 0.9 4.6 0.4 48 22 42 255 20 0.3 20.5 19.4 08/04/2005 09:40:00 2.5 0.8 4.6 0.4 2.7 0.8 4.9 0.7 2.3 0.8 4.6 0.4 54 28 39 255 19.7 0.1 20.3 19.4 08/04/2005 09:50:00 2.7 0.7 3.8 0.7 2.9 0.6 4.2 1.1 2.5 0.7 3.8 0.7 32 27 52 255 19.4 0.1 20 18.8 08/04/2005 10:00:00 1.5 0.6 3 0.4 1.8 0.6 3 0.4 1.1 0.7 2.6 0.4 38 35 3 255 18.8 0.1 19.4 18.5 08/04/2005 10:10:00 0.9 0.6 2.3 0.4 1.2 0.7 2.6 0.4 0.8 0.6 2.6 0.4 52 27 91 255 19.1 0.3 20 18.5 08/04/2005 10:20:00 2.1 0.7 3.8 0.4 2.2 0.7 4.2 0.4 1.4 0.7 3 0.4 9 20 41 255 20 0.3 20.8 19.4 08/04/2005 10:30:00 1.4 0.8 3 0.4 1.4 0.8 3 0.4 1.1 0.6 2.6 0.4 351 35 345 255 20.5 0 21.1 20.3 08/04/2005 10:40:00 2 0.7 3.4 0.4 2 0.8 3.8 0.4 1.6 0.8 3.4 0.4 356 20 22 255 20.5 0 20.8 20.3 08/04/2005 10:50:00 2 0.8 3.8 0.4 1.9 0.8 3.4 0.4 1.6 0.8 3.4 0.4 344 17 338 255 20.7 0 21.1 20.5 08/04/2005 11:00:00 2.1 0.7 3.4 0.4 2.1 0.7 3.8 0.4 1.6 0.7 3.4 0.4 340 23 324 255 21 0.2 21.1 20.5 08/04/2005 11:10:00 2.2 1 4.9 0.4 2.4 0.9 4.9 0.7 1.7 1 4.6 0.4 15 23 22 255 20.5 0 21.1 20.5 08/04/2005 11:20:00 2.3 0.7 4.2 0.7 2.6 0.6 4.2 1.1 2 0.7 3.8 0.4 39 28 353 255 20.5 0 20.8 20.3 08/04/2005 11:30:00 2.3 0.8 3.8 0.4 2.6 0.7 4.2 0.4 2.1 0.8 3.8 0.4 15 26 21 255 20.3 0 20.8 20.3 08/04/2005 11:40:00 2.7 0.6 4.6 1.1 3 0.6 4.6 1.5 2.3 0.8 4.2 0.4 22 13 40 255 20.3 0 20.5 20 08/04/2005 11:50:00 2.5 0.6 3.8 0.7 2.8 0.5 4.2 1.5 2 0.8 3.8 0.4 25 21 23 255 19.4 0 20 19.1 08/04/2005 12:00:00 1.2 0.7 3 0.4 1.7 0.7 3.4 0.4 1.1 0.7 2.6 0.4 8 26 30 255 19.3 0 19.4 19.1 08/04/2005 12:10:00 1.3 0.6 2.6 0.4 1.8 0.6 3 0.4 1 0.6 2.6 0.4 357 21 18 255 19.3 0.2 20 18.8 08/04/2005 12:20:00 1.3 0.6 2.6 0.4 1.8 0.6 3 0.4 1.3 0.7 2.6 0.4 353 13 333 255 20.2 0.2 20.8 19.7 08/04/2005 12:30:00 1.4 0.9 3.4 0.4 1.6 0.8 3.8 0.4 1.3 0.8 3.4 0.4 343 11 355 255 20.5 0 20.8 20.5 08/04/2005 12:40:00 1.3 0.9 3.4 0.4 1.7 0.8 3.8 0.4 1.4 0.9 3.8 0.4 358 29 28 255 20.5 0 20.5 20.3 08/04/2005 12:50:00 2.1 0.8 3.4 0.4 2.5 0.7 3.8 0.7 2 0.8 3.4 0.4 47 27 45 255 20 0.1 20.5 19.7 08/04/2005 13:00:00 1.2 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.1 0.8 3.8 0.4 6 33 305 255 20.9 0.1 21.1 20.5 08/04/2005 13:10:00 1.5 0.8 3.4 0.4 1.9 0.6 3.8 0.4 1.3 0.7 3.4 0.4 353 21 356 255 21 0 21.1 20.8 08/04/2005 13:20:00 2.2 0.7 4.6 0.7 2.5 0.7 4.6 0.7 2.2 0.8 4.2 0.4 8 23 15 255 20.7 0.1 21.1 20.5 08/04/2005 13:30:00 1.6 0.7 3 0.4 2.1 0.6 3.4 0.4 1.3 0.7 2.6 0.4 351 36 347 255 20.4 0 20.5 20.3 08/04/2005 13:40:00 1.6 0.6 3 0.4 2.1 0.5 3.4 1.1 1.4 0.6 2.6 0.4 359 12 358 255 20.5 0 20.8 20.5 08/04/2005 13:50:00 1.4 0.7 3.4 0.4 2 0.6 3.4 0.7 1.5 0.7 3.4 0.4 25 18 18 255 20.4 0 20.5 20.3 08/04/2005 14:00:00 1.3 0.8 3.4 0.4 1.9 0.6 3.8 0.7 1.5 0.6 3 0.4 48 17 19 255 20.3 0 20.5 20.3 08/04/2005 14:10:00 1.7 0.7 3.4 0.4 2.2 0.6 3.4 0.7 1.7 0.8 3.4 0.4 34 13 19 255 20.5 0 20.5 20.3 08/04/2005 14:20:00 1.8 0.8 3.4 0.4 2.3 0.6 3.8 1.1 1.8 0.8 3.4 0.4 10 16 6 255 20.8 0.1 21.1 20.5 08/04/2005 14:30:00 1.6 0.7 3.4 0.4 2.1 0.7 3.8 0.4 1.7 0.8 3.4 0.4 5 23 21 255 21.6 0.1 22 21.1 08/04/2005 14:40:00 2.1 0.9 3.8 0.4 2.5 0.7 3.8 0.4 1.8 0.6 3.4 0.4 30 21 2 255 22.1 0.1 22.6 21.7 08/04/2005 14:50:00 2.9 0.5 4.2 1.9 3.2 0.5 4.6 1.9 2.7 0.7 4.6 0.7 20 15 25 255 23 0.2 23.5 22.6 08/04/2005 15:00:00 2.9 0.7 4.9 0.7 2.9 0.6 4.2 1.1 2.5 0.8 4.2 0.7 343 18 332 255 23.5 0 23.8 23.2 08/04/2005 15:10:00 2 1 3.8 0.4 2.2 0.9 4.2 0.4 2.1 0.9 4.6 0.4 336 33 346 255 23.8 0 24.1 23.5 08/04/2005 15:20:00 1.8 1.2 4.2 0.4 2.1 1 3.8 0.4 1.7 1.2 4.6 0.4 344 27 333 255 23.5 0 23.8 23.5 08/04/2005 15:30:00 1.5 0.9 3.4 0.4 1.9 0.9 3.8 0.4 1.4 0.9 3.4 0.4 315 26 333 255 23.6 0 23.8 23.5 08/04/2005 15:40:00 1.3 0.7 3.8 0.4 1.8 0.5 3.4 0.4 1.2 0.7 3.4 0.4 341 35 328 255 23.9 0 24.1 23.8 08/04/2005 15:50:00 2.1 0.7 3.8 0.4 2.5 0.7 3.8 0.4 1.6 0.7 3.4 0.4 0 22 1 255 23.8 0 24.1 23.5 08/04/2005 16:00:00 2.4 1 4.9 0.4 2.6 0.9 4.9 0.4 2 0.8 4.9 0.4 348 22 19 255 23.7 0 24.1 23.5 08/04/2005 16:10:00 2.6 0.8 4.2 0.4 2.8 0.7 4.2 1.1 2.3 0.8 4.6 0.4 10 23 28 255 23 0.1 23.5 22.9 08/04/2005 16:20:00 2.9 0.9 5.3 0.4 3 0.9 5.3 0.7 2.3 1 6.5 0.4 0 22 19 255 22.8 0 23.2 22.6 08/04/2005 16:30:00 2.8 0.6 4.6 0.7 3.1 0.6 4.9 1.5 2.5 0.6 4.2 0.7 38 15 43 255 22.3 0.2 22.9 21.7 08/04/2005 16:40:00 2.6 1 5.7 0.4 2.9 0.9 6.1 0.7 1.8 0.9 4.6 0.4 357 16 11 255 21.6 0 22 21.4 08/04/2005 16:50:00 2.4 0.8 3.8 0.4 2.6 0.8 4.2 0.7 2 0.8 3.8 0.4 341 22 5 255 21.3 0 21.4 21.1 08/04/2005 17:00:00 1.6 1 3.8 0.4 1.8 1 3.8 0.4 1.2 0.8 3 0.4 340 16 321 255 21 0 21.1 20.8 08/04/2005 17:10:00 1.8 0.8 3.8 0.4 2.1 0.6 3.8 0.7 1.5 0.7 3 0.4 338 24 349 255 20.5 0.3 21.1 20 08/04/2005 17:20:00 1.2 0.7 2.6 0.4 1.6 0.5 3 0.4 1.2 0.6 2.6 0.4 326 11 331 255 19.6 0.1 20 19.4 08/04/2005 17:30:00 0.9 0.5 1.9 0.4 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 339 13 342 255 19.4 0 19.4 19.1 08/04/2005 17:40:00 1.8 0.6 3.4 0.4 2 0.6 3.4 0.7 1.4 0.6 3 0.4 324 18 306 255 19 0 19.4 18.8 08/04/2005 17:50:00 2.4 0.8 4.2 0.4 2.7 0.6 4.6 0.7 2.2 0.8 4.6 0.4 293 17 291 255 18.9 0 19.4 18.5 08/04/2005 18:00:00 1 0.7 3 0.4 1.6 0.7 3 0.4 0.9 0.7 3.4 0.4 280 18 286 255 18.7 0 19.4 18.5 08/04/2005 18:10:00 0.9 0.7 3 0.4 1.6 0.6 3 0.4 0.8 0.5 2.6 0.4 241 17 234 255 18.4 0 19.1 18 08/04/2005 18:20:00 0.5 0.3 1.5 0.4 1.1 0.5 1.9 0.4 0.5 0.2 1.5 0.4 227 12 221 255 17.8 0.2 18.5 17.4 08/04/2005 18:30:00 0.8 0.6 2.6 0.4 1.4 0.6 3 0.4 0.7 0.4 1.9 0.4 215 9 216 255 17.1 0 17.4 16.8 08/04/2005 18:40:00 0.5 0.4 2.3 0.4 0.8 0.5 2.6 0.4 0.5 0.3 1.9 0.4 237 18 220 255 16.8 0 16.8 16.6 08/04/2005 18:50:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 258 1 255 255 16.5 0 16.8 16.3 08/04/2005 19:00:00 0.4 0 0.4 0.4 1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 281 7 255 255 16.1 0 16.6 16 08/04/2005 19:10:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 298 0 255 255 15.9 0 16.3 15.7 08/04/2005 19:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 298 0 255 255 15.7 0 16 15.5 08/04/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 15.5 0 15.7 15.2 08/04/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 15.2 0 15.5 15.2 08/04/2005 19:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 298 0 255 255 15 0 15.7 14.9 08/04/2005 20:00:00 0.4 0.1 0.7 0.4 1.1 0.2 1.5 0.7 0.4 0 0.7 0.4 2 15 12 255 15 0 15.2 14.9 08/04/2005 20:10:00 0.9 0.4 1.5 0.4 1.6 0.3 2.3 0.7 0.6 0.3 1.5 0.4 12 0 12 255 14.8 0 15.2 14.6 08/04/2005 20:20:00 0.6 0.3 1.5 0.4 1.1 0.5 1.9 0.4 0.4 0.1 1.1 0.4 11 5 12 255 14.7 0.1 15.2 14.6 08/04/2005 20:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 350 0 255 255 14.6 0 15.2 14.6 08/04/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 14.7 0 15.2 14.6 08/04/2005 20:50:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 20 19 255 255 14.6 0 15.2 14.6 08/04/2005 21:00:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 32 0 255 255 14.6 0 14.9 14.6 08/04/2005 21:10:00 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.4 0.4 0.1 0.7 0.4 36 6 46 255 14.6 0 15.2 14.6 08/04/2005 21:20:00 0.6 0.4 1.9 0.4 1.3 0.4 2.6 0.7 0.6 0.4 1.9 0.4 54 5 63 255 14.5 0 15.2 14.6 08/04/2005 21:30:00 1.8 0.8 3.4 0.4 2.3 0.6 3.8 1.1 1.4 0.6 2.6 0.4 45 10 41 255 14.5 0 14.9 14.4 08/04/2005 21:40:00 0.6 0.4 1.5 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.5 0.4 59 9 53 255 14.2 0.2 14.9 13.8 08/04/2005 21:50:00 1 0.5 1.9 0.4 1.6 0.4 2.3 0.7 0.8 0.4 1.5 0.4 49 10 56 255 13.9 0.1 14.6 13.5 08/04/2005 22:00:00 0.9 0.6 2.3 0.4 1.5 0.5 2.6 0.7 1 0.4 1.9 0.4 58 7 61 255 13.4 0 13.8 13 08/04/2005 22:10:00 1.5 0.3 2.6 0.7 2 0.3 2.6 1.5 1.3 0.3 1.9 0.7 59 5 59 255 12.9 0.1 13.3 12.7 08/04/2005 22:20:00 0.8 0.4 1.9 0.4 1.5 0.3 2.3 0.7 0.5 0.3 1.5 0.4 49 11 57 255 12.6 0 12.7 12.5 08/04/2005 22:30:00 0.6 0.4 1.9 0.4 1.3 0.3 2.3 0.7 0.4 0.1 1.1 0.4 45 9 28 255 12.4 0 12.5 12.2 08/04/2005 22:40:00 1 0.5 2.6 0.4 1.6 0.4 3 0.7 1 0.4 1.9 0.4 63 8 66 255 12.3 0 12.5 12.2 08/04/2005 22:50:00 1.4 0.5 2.6 0.4 1.9 0.4 3 1.1 0.8 0.4 1.9 0.4 60 7 71 255 12.1 0 12.2 11.9 08/04/2005 23:00:00 0.7 0.3 1.5 0.4 1.2 0.4 1.9 0.4 0.5 0.3 1.5 0.4 48 5 56 255 12.1 0 12.2 11.9 08/04/2005 23:10:00 1.2 0.5 2.3 0.4 1.7 0.4 2.6 1.1 0.9 0.4 1.9 0.4 65 12 70 255 12.1 0 12.7 11.9 08/04/2005 23:20:00 1.3 0.4 2.6 0.4 1.7 0.3 2.6 1.1 0.8 0.4 2.3 0.4 76 9 68 255 12 0 12.2 11.9 08/04/2005 23:30:00 1.1 0.4 1.9 0.4 1.5 0.4 2.3 0.7 0.8 0.3 1.5 0.4 82 13 69 255 12.1 0 12.2 11.9 08/04/2005 23:40:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 99 0 255 255 12.1 0 12.5 11.9 08/04/2005 23:50:00 0.4 0.2 1.5 0.4 0.9 0.3 1.9 0.4 0.4 0 0.7 0.4 90 6 86 255 12.3 0 12.7 12.2 08/05/2005 00:00:00 1.2 0.4 2.3 0.4 1.6 0.3 2.3 0.7 0.7 0.3 1.5 0.4 68 8 64 255 12.3 0 12.7 12.2 08/05/2005 00:10:00 0.6 0.3 1.5 0.4 1 0.4 2.3 0.4 0.4 0.1 1.1 0.4 59 5 56 255 12.3 0 12.7 12.2 08/05/2005 00:20:00 1.8 0.5 2.6 0.4 2 0.4 3 0.7 0.9 0.5 2.3 0.4 61 11 73 255 12.3 0 12.7 12.2 08/05/2005 00:30:00 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 53 4 49 255 12.3 0 12.7 12.2 08/05/2005 00:40:00 0.9 0.5 1.9 0.4 1.3 0.4 2.3 0.4 0.5 0.3 1.5 0.4 47 7 51 255 12.3 0 12.7 12.2 08/05/2005 00:50:00 1.4 0.6 3 0.4 1.7 0.5 3.4 0.4 0.8 0.5 1.9 0.4 64 8 71 255 12.5 0 12.5 12.5 08/05/2005 01:00:00 1.2 0.6 2.6 0.4 1.4 0.6 3 0.4 0.6 0.4 1.9 0.4 54 15 62 255 12.5 0 13 12.5 08/05/2005 01:10:00 1.1 0.5 2.6 0.4 1.4 0.5 3 0.4 0.8 0.4 1.9 0.4 53 13 45 255 12.7 0 13.3 12.5 08/05/2005 01:20:00 1.5 0.5 2.6 0.4 1.8 0.5 3 0.7 1 0.5 2.3 0.4 70 11 62 255 12.8 0 13.3 12.7 08/05/2005 01:30:00 1.7 0.4 2.3 0.4 1.9 0.3 2.6 0.4 0.7 0.4 1.9 0.4 96 8 88 255 12.8 0 13.5 12.7 08/05/2005 01:40:00 1.8 0.4 3 0.7 1.9 0.4 2.6 1.1 1 0.5 2.3 0.4 108 9 112 255 12.6 0 13 12.5 08/05/2005 01:50:00 1.7 0.5 3 0.7 1.8 0.4 2.6 0.7 0.8 0.5 1.9 0.4 104 14 93 255 12.7 0 13 12.5 08/05/2005 02:00:00 1.2 0.5 2.3 0.4 1.5 0.4 2.3 0.4 0.5 0.3 1.5 0.4 76 6 80 255 12.7 0 13 12.5 08/05/2005 02:10:00 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 58 8 70 255 12.6 0 13 12.5 08/05/2005 02:20:00 0.8 0.3 1.5 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 70 0 70 255 12.5 0 12.7 12.5 08/05/2005 02:30:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 70 0 70 255 12.5 0 12.5 12.5 08/05/2005 02:40:00 0.7 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 111 26 124 255 12.5 0 12.5 12.5 08/05/2005 02:50:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 0.7 0.3 1.5 0.4 52 26 27 255 12.5 0 12.7 12.5 08/05/2005 03:00:00 0.6 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 134 14 127 255 12.5 0 12.7 12.5 08/05/2005 03:10:00 2 0.5 3.4 0.7 2.1 0.5 3.4 0.7 1 0.6 2.3 0.4 132 17 123 255 12.5 0 12.7 12.5 08/05/2005 03:20:00 2.3 0.4 3 1.5 2.3 0.4 3 1.5 1.3 0.4 2.3 0.4 42 27 15 255 12.7 0 12.7 12.5 08/05/2005 03:30:00 2 0.7 3.4 0.4 2 0.7 3 0.4 0.4 0.2 1.5 0.4 24 23 14 255 12.8 0 12.7 12.7 08/05/2005 03:40:00 0.6 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.5 0.4 138 9 138 255 12.8 0 13.3 12.7 08/05/2005 03:50:00 1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 113 39 155 255 13.1 0 13.5 12.7 08/05/2005 04:00:00 1.5 0.8 3 0.4 1.5 0.8 3 0.4 1 0.7 2.6 0.4 19 22 35 255 13.3 0 13.3 13 08/05/2005 04:10:00 0.9 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 357 17 16 255 13.2 0 13.3 13 08/05/2005 04:20:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 358 12 6 255 12.9 0 13 12.7 08/05/2005 04:30:00 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.4 0.2 1.5 0.4 3 9 12 255 12.7 0 13 12.5 08/05/2005 04:40:00 2 0.4 2.6 1.1 2 0.3 2.6 1.1 0.9 0.5 1.9 0.4 20 8 19 255 12.5 0 13 12.5 08/05/2005 04:50:00 2.2 0.7 3.4 0.7 2.2 0.7 3.4 0.4 1.6 0.8 3 0.4 35 11 39 255 12.5 0 13 12.5 08/05/2005 05:00:00 1.7 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.2 0.7 3 0.4 27 12 39 255 12.7 0 13 12.7 08/05/2005 05:10:00 1.2 0.4 1.9 0.4 1.1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 354 10 6 255 12.6 0 12.7 12.5 08/05/2005 05:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 353 3 350 255 12.4 0 12.7 12.5 08/05/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 0 255 255 12.4 0 12.7 12.2 08/05/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 0 255 255 12.4 0 12.7 12.2 08/05/2005 05:50:00 0.5 0.4 1.9 0.4 0.6 0.5 2.3 0.4 0.4 0.1 1.5 0.4 25 28 58 255 12.5 0 12.7 12.5 08/05/2005 06:00:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 97 10 94 255 12.7 0 13.3 12.5 08/05/2005 06:10:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 85 12 100 255 12.9 0.1 13.3 12.7 08/05/2005 06:20:00 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 87 8 83 255 13.3 0 13.5 13 08/05/2005 06:30:00 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 0.5 0.3 1.5 0.4 117 19 88 255 13.7 0.1 14.6 13.5 08/05/2005 06:40:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.7 0.4 1.9 0.4 108 11 96 255 14.1 0.1 14.9 13.8 08/05/2005 06:50:00 1.7 0.4 2.6 0.4 1.6 0.5 2.6 0.4 0.9 0.4 1.9 0.4 109 13 108 255 14.4 0 15.2 14.4 08/05/2005 07:00:00 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 90 12 106 255 14.6 0.1 15.2 14.6 08/05/2005 07:10:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.2 1.5 0.4 106 12 99 255 14.8 0 15.2 14.6 08/05/2005 07:20:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 126 18 102 255 15 0 15.5 14.9 08/05/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 1 255 255 15.3 0 15.7 15.2 08/05/2005 07:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 157 0 157 255 15.8 0 16.3 15.7 08/05/2005 07:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 97 17 116 255 16.1 0 16.6 16 08/05/2005 08:00:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 56 28 14 255 16.5 0 16.8 16.3 08/05/2005 08:10:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 31 13 20 255 16.7 0 17.1 16.6 08/05/2005 08:20:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 34 26 58 255 16.8 0 17.1 16.8 08/05/2005 08:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 15 8 27 255 16.9 0 17.4 16.8 08/05/2005 08:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 14 13 347 255 17.3 0.1 17.4 17.1 08/05/2005 08:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 2 8 17 255 17.4 0 17.7 17.1 08/05/2005 09:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 356 22 358 255 17.6 0 18 17.4 08/05/2005 09:10:00 0.6 0.4 1.9 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 0 24 3 255 18 0 18.2 17.7 08/05/2005 09:20:00 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 3 20 2 255 18 0 18.2 17.7 08/05/2005 09:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 9 23 14 255 18.4 0.1 18.8 18 08/05/2005 09:40:00 1 0.4 1.9 0.4 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 29 32 27 255 19 0 19.4 18.8 08/05/2005 09:50:00 2.6 0.6 3.8 1.1 2.6 0.6 3.8 1.1 1.8 0.7 3.4 0.4 4 13 354 255 19 0.1 19.4 18.8 08/05/2005 10:00:00 2.8 0.6 3.8 1.1 2.7 0.6 3.8 1.1 1.8 0.7 3.4 0.4 6 15 352 255 18.9 0.1 19.4 18.5 08/05/2005 10:10:00 2.3 0.6 3.8 0.4 2.2 0.7 3.8 0.4 1.4 0.8 3 0.4 9 13 23 255 18.5 0.1 19.1 18.2 08/05/2005 10:20:00 2.3 0.6 3.4 0.7 2.3 0.6 3.4 0.4 1.4 0.7 3 0.4 5 11 8 255 18.2 0 18.8 18 08/05/2005 10:30:00 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.2 0.6 2.6 0.4 351 13 4 255 18.4 0.1 19.1 18 08/05/2005 10:40:00 2.1 0.6 3.4 0.4 1.9 0.5 3 0.4 1.5 0.6 3.4 0.4 351 17 354 255 18.6 0 19.1 18.5 08/05/2005 10:50:00 2 0.6 3 0.4 2.1 0.6 3 0.4 1.3 0.8 3.4 0.4 5 19 22 255 18.5 0.1 19.1 18.2 08/05/2005 11:00:00 2.2 0.4 3.4 1.1 2.3 0.4 3.4 1.1 1.5 0.5 3 0.4 4 10 358 255 18.7 0.3 19.4 18.2 08/05/2005 11:10:00 1.6 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1.2 0.7 3 0.4 349 15 5 255 19.5 0.2 20.5 19.1 08/05/2005 11:20:00 1.4 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.1 0.5 2.3 0.4 355 17 357 255 19.7 0.2 20.5 19.4 08/05/2005 11:30:00 1.6 0.6 3 0.4 1.6 0.5 3 0.4 1 0.5 2.3 0.4 358 28 3 255 19.4 0 20 19.1 08/05/2005 11:40:00 1.8 0.6 3 0.4 1.8 0.7 3 0.4 1.5 0.7 3 0.4 349 13 353 255 19.7 0.1 20 19.4 08/05/2005 11:50:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.1 0.6 3 0.4 334 17 315 255 19.5 0 20 19.1 08/05/2005 12:00:00 1.6 0.5 2.6 0.4 1.6 0.5 3 0.4 1.3 0.7 2.6 0.4 339 20 354 255 19.7 0.3 20.3 19.1 08/05/2005 12:10:00 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.5 0.7 3 0.4 355 21 25 255 20.7 0.2 21.4 20.3 08/05/2005 12:20:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.7 3 0.4 338 32 14 255 21.3 0 21.4 21.1 08/05/2005 12:30:00 1.9 0.7 3.8 0.4 1.9 0.6 3.4 0.4 1.4 0.8 3.4 0.4 330 33 338 255 21.4 0 21.7 21.1 08/05/2005 12:40:00 2 0.7 3.4 0.4 2.1 0.7 3.8 0.4 1.3 0.7 3 0.4 11 20 341 255 22 0 22.6 21.7 08/05/2005 12:50:00 2.2 0.9 4.2 0.4 2.1 0.7 3.8 0.4 2 1 4.2 0.4 326 18 337 255 22.1 0 22.6 22 08/05/2005 13:00:00 1.3 0.9 4.2 0.4 1.3 0.8 4.2 0.4 0.9 0.7 3.4 0.4 303 66 10 255 22 0.1 22.6 21.7 08/05/2005 13:10:00 1.2 0.8 3 0.4 1.4 0.7 3.4 0.4 1 0.7 3.4 0.4 300 82 255 255 22.4 0.2 22.9 22 08/05/2005 13:20:00 1.4 0.9 3.8 0.4 1.6 0.8 3.4 0.4 1.2 0.8 4.2 0.4 318 38 346 255 22.2 0 22.6 21.7 08/05/2005 13:30:00 0.9 0.7 3 0.4 1.1 0.8 3 0.4 0.9 0.7 3 0.4 285 35 243 255 22.9 0.1 23.5 22.6 08/05/2005 13:40:00 0.9 1 4.2 0.4 1 1 4.6 0.4 0.8 1 4.2 0.4 33 102 300 255 23.3 0.2 23.5 22.9 08/05/2005 13:50:00 2.6 1 5.7 0.7 2.6 1 5.7 0.7 1.8 1.2 6.1 0.4 334 30 310 255 23.6 0.1 24.1 23.5 08/05/2005 14:00:00 3 0.8 5.3 0.7 3 0.8 5.3 0.7 2.4 0.9 4.2 0.4 316 22 322 255 23.8 0.2 24.4 23.5 08/05/2005 14:10:00 2.6 1 4.6 0.4 2.8 0.9 4.9 0.4 2.3 1 4.6 0.4 283 29 287 255 23 0.2 23.5 22.9 08/05/2005 14:20:00 2.3 1.4 6.1 0.4 2.4 1.4 6.5 0.4 2 1.4 6.5 0.4 316 35 292 255 22.9 0 23.2 22.9 08/05/2005 14:30:00 2.5 1 4.9 0.4 2.7 0.9 4.9 0.7 2.2 1 4.2 0.4 283 26 288 255 23 0 23.5 22.9 08/05/2005 14:40:00 2.4 1.2 5.3 0.4 2.6 1.2 5.3 0.4 2.2 1.2 5.3 0.4 304 27 286 255 23.8 0.1 24.1 23.5 08/05/2005 14:50:00 1.9 0.9 4.2 0.4 2 0.8 4.2 0.4 1.6 0.8 3.8 0.4 325 32 315 255 23.4 0.5 24.1 22.3 08/05/2005 15:00:00 1.7 1 3.4 0.4 1.8 0.8 3.4 0.4 1.5 0.8 3 0.4 354 33 345 255 21.6 0.2 22.3 21.1 08/05/2005 15:10:00 1.3 0.8 4.2 0.4 1.5 0.7 3.8 0.4 1 0.6 3 0.4 269 51 281 255 23.3 0.6 23.8 22 08/05/2005 15:20:00 2.4 1.3 5.3 0.4 2.5 1.2 5.3 0.4 2.1 1.2 4.9 0.4 282 18 308 255 23.5 0 23.8 23.5 08/05/2005 15:30:00 2.3 1 4.6 0.4 2.3 1 4.6 0.4 1.8 1.1 4.6 0.4 312 21 312 255 23.8 0 24.1 23.5 08/05/2005 15:40:00 2.2 0.9 4.6 0.4 2.2 0.8 4.2 0.4 1.7 0.9 4.2 0.4 325 49 4 255 24.1 0 24.4 23.8 08/05/2005 15:50:00 1.5 0.9 3.8 0.4 1.6 0.8 3.8 0.4 0.9 0.7 3 0.4 331 33 352 255 24.2 0 24.4 24.1 08/05/2005 16:00:00 3.4 0.8 4.9 0.7 3.4 0.8 4.9 1.1 2.5 0.8 4.2 0.4 10 18 36 255 24.3 0 24.4 24.1 08/05/2005 16:10:00 2.7 1.5 5.3 0.4 2.8 1.3 5.3 0.4 2.2 1.4 4.9 0.4 15 38 31 255 23.8 0.2 24.4 23.5 08/05/2005 16:20:00 2.8 0.7 4.6 0.7 2.6 0.7 4.6 1.1 2.3 0.7 4.2 0.4 347 16 11 255 24.3 0 24.4 24.1 08/05/2005 16:30:00 2.3 0.8 4.6 0.4 2.4 0.8 4.6 0.7 1.9 0.9 3.8 0.4 20 22 3 255 24.1 0.2 24.4 23.5 08/05/2005 16:40:00 2 0.7 3.4 0.4 2 0.6 3.4 0.4 1.7 0.7 3.8 0.4 7 32 30 255 23.6 0 23.8 23.5 08/05/2005 16:50:00 2.2 1 4.9 0.4 2.3 1 4.9 0.7 1.5 0.8 4.6 0.4 22 29 14 255 23 0 23.5 22.9 08/05/2005 17:00:00 2.3 0.9 4.2 0.4 2.4 0.9 4.6 0.4 1.9 0.8 3.8 0.4 36 28 5 255 22.7 0 23.2 22.3 08/05/2005 17:10:00 1.5 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.3 0.6 3 0.4 29 27 21 255 22.4 0 22.6 22.3 08/05/2005 17:20:00 0.9 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 67 26 80 255 22.1 0.1 22.3 21.7 08/05/2005 17:30:00 0.5 0.4 2.3 0.4 0.7 0.5 2.6 0.4 0.4 0.3 2.3 0.4 26 49 291 255 21.5 0.1 22 21.1 08/05/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 56 2 255 255 21 0.2 21.4 20.5 08/05/2005 17:50:00 0.8 0.6 3 0.4 1 0.7 3 0.4 0.6 0.5 2.3 0.4 265 64 146 255 20.4 0 20.8 20 08/05/2005 18:00:00 1.4 0.8 3 0.4 1.5 0.7 3 0.4 1.2 0.7 2.6 0.4 149 7 148 255 19.8 0 20.3 19.4 08/05/2005 18:10:00 1.4 0.4 2.3 0.4 1.6 0.3 2.6 0.7 1.1 0.4 2.3 0.4 133 9 137 255 19.5 0.1 20 19.4 08/05/2005 18:20:00 1.3 0.4 2.3 0.4 1.4 0.3 2.3 0.7 1.1 0.3 1.9 0.4 131 7 120 255 19.5 0 20 19.4 08/05/2005 18:30:00 1.6 0.5 2.3 0.4 1.6 0.5 2.3 0.7 1.2 0.4 2.3 0.4 130 8 113 255 19.3 0 20 19.1 08/05/2005 18:40:00 1.8 0.5 3 0.4 1.8 0.5 2.6 0.7 1.4 0.6 3 0.4 141 8 136 255 19.1 0 19.7 18.8 08/05/2005 18:50:00 2.1 0.5 3.4 1.1 2.1 0.4 3.4 1.1 1.7 0.5 3 0.4 157 10 158 255 18.7 0 19.4 18.5 08/05/2005 19:00:00 2.6 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2 0.7 3.8 0.4 144 15 134 255 18.6 0 19.1 18.5 08/05/2005 19:10:00 2.1 0.6 3.4 0.7 2.1 0.5 3.4 0.7 1.4 0.6 3 0.4 123 11 148 255 18.7 0 19.4 18.5 08/05/2005 19:20:00 1.9 0.4 2.6 1.1 1.9 0.3 2.6 0.7 1.2 0.4 2.3 0.4 103 13 127 255 18.9 0 19.4 18.8 08/05/2005 19:30:00 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.4 0.9 0.4 2.3 0.4 92 11 104 255 19 0 19.4 18.8 08/05/2005 19:40:00 1.3 0.4 2.3 0.4 1.2 0.4 1.9 0.4 0.6 0.4 1.9 0.4 91 15 121 255 18.8 0.2 19.1 18.2 08/05/2005 19:50:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.6 0.6 2.6 0.4 142 12 160 255 18.2 0 18.2 18 08/05/2005 20:00:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 0.8 0.5 2.3 0.4 110 11 119 255 18 0 18.2 17.7 08/05/2005 20:10:00 2 0.4 3 0.7 2 0.4 3 0.4 1 0.4 1.9 0.4 107 9 109 255 17.5 0.2 17.7 17.1 08/05/2005 20:20:00 2.3 0.3 3 1.5 2.2 0.3 3 1.1 1.3 0.4 2.6 0.4 78 6 68 255 17.1 0 17.1 16.8 08/05/2005 20:30:00 1.9 0.2 2.6 1.1 1.8 0.3 2.6 1.1 1.1 0.3 1.9 0.4 80 5 68 255 16.7 0 16.8 16.6 08/05/2005 20:40:00 2 0.3 3 1.1 1.9 0.3 2.6 0.7 1.1 0.4 1.9 0.4 61 15 37 255 16.6 0 16.8 16.3 08/05/2005 20:50:00 1.6 0.3 2.6 0.7 1.5 0.4 2.6 0.4 0.8 0.4 1.9 0.4 57 9 45 255 16.3 0.1 16.8 16.3 08/05/2005 21:00:00 1.3 0.3 1.9 0.7 1.1 0.4 1.9 0.4 0.6 0.2 1.5 0.4 63 10 80 255 16.1 0 16.3 15.7 08/05/2005 21:10:00 1.5 0.4 2.6 0.7 1.4 0.4 2.6 0.7 0.8 0.5 1.9 0.4 69 13 85 255 15.7 0 16 15.5 08/05/2005 21:20:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.1 1.2 0.3 1.9 0.4 71 6 76 255 15.4 0.1 15.7 15.2 08/05/2005 21:30:00 1.9 0.4 2.6 1.1 1.8 0.4 3 0.7 1.2 0.4 2.6 0.4 58 9 77 255 15 0 15.5 14.9 08/05/2005 21:40:00 1.9 0.4 3 1.1 1.8 0.5 3 0.7 1.1 0.5 2.3 0.4 62 9 72 255 14.6 0 14.9 14.4 08/05/2005 21:50:00 2.2 0.5 3 1.1 2.1 0.5 3 0.7 0.8 0.5 2.3 0.4 81 9 78 255 14.2 0.1 14.9 13.8 08/05/2005 22:00:00 2.6 0.4 3.8 1.9 2.6 0.4 3.4 1.5 1.7 0.4 2.6 0.4 72 7 62 255 13.9 0 14.4 13.5 08/05/2005 22:10:00 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.5 1.4 0.5 2.6 0.4 68 8 73 255 13.6 0.1 13.8 13.3 08/05/2005 22:20:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.1 0.6 2.6 0.4 72 13 70 255 13.4 0 13.8 13.3 08/05/2005 22:30:00 1.9 0.5 3 0.7 1.9 0.5 3 0.7 0.9 0.5 2.3 0.4 88 9 93 255 13.1 0.1 13.8 12.7 08/05/2005 22:40:00 2.1 0.4 3 0.7 2 0.5 3 0.7 1.3 0.5 2.6 0.4 73 10 73 255 13.2 0 13.8 12.7 08/05/2005 22:50:00 1.9 0.4 3 0.7 1.8 0.5 3.4 0.7 1.1 0.5 2.6 0.4 41 10 30 255 13.2 0 13.8 13 08/05/2005 23:00:00 1.9 0.4 3 0.7 1.8 0.5 2.6 0.7 1.1 0.5 2.3 0.4 53 13 26 255 13.1 0.1 13.3 12.7 08/05/2005 23:10:00 1.4 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 47 10 55 255 12.7 0 13.3 12.5 08/05/2005 23:20:00 1.6 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.8 0.4 1.9 0.4 52 9 60 255 12.5 0.1 12.7 12.5 08/05/2005 23:30:00 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 46 14 52 255 12.4 0 12.7 12.2 08/05/2005 23:40:00 1 0.4 2.3 0.4 0.7 0.3 2.3 0.4 0.4 0.2 1.1 0.4 48 10 40 255 12.3 0 12.7 12.2 08/05/2005 23:50:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 66 22 86 255 12.1 0 12.5 11.9 08/06/2005 00:00:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 77 6 80 255 12.1 0 12.5 11.9 08/06/2005 00:10:00 1.5 0.2 1.9 1.1 1.3 0.2 1.9 0.4 0.5 0.3 1.5 0.4 73 7 91 255 12 0 12.2 11.9 08/06/2005 00:20:00 1.3 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 62 6 64 255 12.1 0 12.5 11.9 08/06/2005 00:30:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 59 3 61 255 12 0 12.5 11.9 08/06/2005 00:40:00 1.1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 72 10 52 255 12.1 0 12.5 11.9 08/06/2005 00:50:00 1.2 0.3 1.9 0.7 0.9 0.3 1.9 0.4 0.4 0.1 1.1 0.4 83 7 80 255 12.1 0 12.5 11.9 08/06/2005 01:00:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 79 8 83 255 11.9 0 12.2 11.9 08/06/2005 01:10:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 83 17 73 255 11.7 0 12.2 11.7 08/06/2005 01:20:00 1.3 0.3 1.9 0.7 1 0.4 1.9 0.4 1 0.4 1.5 0.4 138 3 138 255 11.7 0 11.9 11.7 08/06/2005 01:30:00 1.1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.1 0.4 130 13 136 255 11.5 0 11.7 11.4 08/06/2005 01:40:00 0.9 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.7 0.4 106 7 111 255 11.4 0 11.7 11.4 08/06/2005 01:50:00 1.4 0.3 2.3 0.4 1.2 0.4 1.9 0.4 0.7 0.4 1.9 0.4 126 8 121 255 11.4 0 11.4 11.4 08/06/2005 02:00:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 118 10 103 255 11.2 0 11.4 11.1 08/06/2005 02:10:00 1.7 0.3 2.3 1.1 1.5 0.3 2.3 1.1 0.4 0.2 1.1 0.4 98 1 103 255 11.1 0 11.7 11.1 08/06/2005 02:20:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 0.6 0.3 1.5 0.4 98 3 97 255 11.1 0 11.1 10.9 08/06/2005 02:30:00 1.8 0.3 2.3 0.7 1.6 0.4 2.3 0.4 0.7 0.4 1.5 0.4 107 8 113 255 10.9 0 11.1 10.9 08/06/2005 02:40:00 2.1 0.2 2.6 1.5 1.9 0.2 2.6 1.1 0.9 0.4 1.5 0.4 102 5 106 255 10.8 0 11.1 10.6 08/06/2005 02:50:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.1 0.8 0.4 1.5 0.4 88 5 97 255 10.7 0 10.9 10.6 08/06/2005 03:00:00 2.1 0.2 2.6 1.5 1.9 0.2 2.6 1.5 0.9 0.3 1.5 0.4 84 2 81 255 10.9 0 10.9 10.9 08/06/2005 03:10:00 2 0.2 2.6 1.5 1.8 0.3 2.6 1.1 0.8 0.4 1.9 0.4 86 2 86 255 10.9 0 11.1 10.9 08/06/2005 03:20:00 1.9 0.3 2.6 1.5 1.8 0.3 2.3 1.1 0.5 0.3 1.1 0.4 93 6 91 255 11.1 0 11.1 10.9 08/06/2005 03:30:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.7 0.8 0.5 1.9 0.4 71 5 68 255 11.2 0 11.4 11.1 08/06/2005 03:40:00 1.4 0.3 2.3 0.7 1.1 0.4 2.6 0.4 0.4 0.1 1.1 0.4 71 9 70 255 11.2 0 11.4 11.1 08/06/2005 03:50:00 1.3 0.2 1.9 0.7 1 0.2 1.5 0.4 0.4 0 0.7 0.4 102 6 89 255 11.5 0 11.7 11.4 08/06/2005 04:00:00 1.4 0.2 1.9 0.7 1.1 0.2 1.5 0.4 0.4 0 0.4 0.4 104 2 105 255 11.6 0 11.7 11.7 08/06/2005 04:10:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 92 0 92 255 11.5 0 11.7 11.4 08/06/2005 04:20:00 1 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 73 18 55 255 11.3 0 11.4 11.1 08/06/2005 04:30:00 1.1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 56 1 55 255 11.2 0 11.4 11.1 08/06/2005 04:40:00 1.6 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.6 0.4 1.9 0.4 62 8 76 255 11.1 0 11.1 11.1 08/06/2005 04:50:00 2.5 0.4 3.4 1.1 2.3 0.4 3.4 1.1 1.2 0.5 2.3 0.4 87 8 91 255 11.1 0 11.4 11.1 08/06/2005 05:00:00 2.3 0.4 3.4 1.5 2.1 0.4 3.4 1.1 0.9 0.4 1.9 0.4 81 12 44 255 11 0 11.1 10.9 08/06/2005 05:10:00 1.8 0.3 2.6 1.1 1.5 0.4 2.6 0.4 0.6 0.4 1.9 0.4 80 7 71 255 11.1 0 11.1 10.9 08/06/2005 05:20:00 1.8 0.3 2.6 1.1 1.5 0.4 2.3 0.7 0.5 0.3 1.5 0.4 103 10 120 255 11 0 11.1 10.9 08/06/2005 05:30:00 2.1 0.4 2.6 1.1 1.8 0.5 2.6 0.4 0.8 0.4 2.3 0.4 107 8 110 255 11 0 11.1 10.9 08/06/2005 05:40:00 2.1 0.4 3 1.5 1.9 0.4 3 0.7 0.9 0.5 2.3 0.4 87 8 93 255 11.3 0 11.4 11.1 08/06/2005 05:50:00 1.8 0.3 2.6 1.1 1.6 0.4 2.3 0.7 0.5 0.2 1.1 0.4 85 5 86 255 11.3 0 11.7 11.1 08/06/2005 06:00:00 2 0.3 2.6 1.1 1.8 0.3 2.3 1.1 0.7 0.4 1.5 0.4 90 5 95 255 11.3 0 11.4 11.1 08/06/2005 06:10:00 1.6 0.4 2.3 0.7 1.4 0.5 2.3 0.4 0.4 0.2 1.1 0.4 94 7 87 255 11.4 0 11.7 11.4 08/06/2005 06:20:00 1.5 0.3 2.3 0.7 1.2 0.3 2.3 0.4 0.4 0.1 1.1 0.4 99 7 104 255 11.7 0 11.9 11.4 08/06/2005 06:30:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 86 8 90 255 12.2 0.1 12.5 11.9 08/06/2005 06:40:00 0.9 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 90 0 90 255 13.2 0.4 13.8 12.5 08/06/2005 06:50:00 1.5 0.4 2.6 0.4 1.4 0.4 2.6 0.4 0.8 0.5 1.9 0.4 73 17 86 255 14.3 0.2 14.6 13.8 08/06/2005 07:00:00 1.8 0.6 3.8 0.4 1.6 0.6 3.4 0.4 1.2 0.7 3 0.4 51 16 40 255 14.9 0 15.5 14.6 08/06/2005 07:10:00 2 0.6 3.4 0.7 1.9 0.7 3.8 0.4 1.5 0.8 3 0.4 35 15 49 255 15 0 15.5 15.2 08/06/2005 07:20:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.4 2.3 0.4 49 13 62 255 15.2 0.1 15.7 15.2 08/06/2005 07:30:00 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 74 22 65 255 16.1 0.3 16.8 15.5 08/06/2005 07:40:00 1.5 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.4 2.3 0.4 56 20 40 255 17.1 0 17.4 16.8 08/06/2005 07:50:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 47 27 21 255 17.2 0 17.7 16.8 08/06/2005 08:00:00 1.7 0.4 3 0.4 1.7 0.5 3 0.4 1.3 0.5 2.6 0.4 48 22 38 255 17.2 0 17.7 16.8 08/06/2005 08:10:00 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.3 0.6 2.3 0.4 64 22 41 255 17 0 17.1 16.8 08/06/2005 08:20:00 1.9 0.5 3 0.7 1.9 0.5 3 0.4 1.4 0.6 3 0.4 65 20 63 255 17.1 0 17.4 16.8 08/06/2005 08:30:00 1.1 0.5 2.3 0.4 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 62 15 68 255 17.3 0 17.4 17.1 08/06/2005 08:40:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.6 2.6 0.4 41 15 58 255 17.3 0 17.4 17.1 08/06/2005 08:50:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 77 16 75 255 17.3 0 17.4 17.1 08/06/2005 09:00:00 1 0.4 1.9 0.4 1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 61 17 60 255 17.4 0 17.7 17.1 08/06/2005 09:10:00 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.2 0.6 3 0.4 53 18 30 255 17.7 0 17.7 17.4 08/06/2005 09:20:00 1.7 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.5 0.5 2.6 0.4 27 11 36 255 17.8 0 18 17.7 08/06/2005 09:30:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 31 13 17 255 18.1 0 18.5 17.7 08/06/2005 09:40:00 1.6 0.4 2.3 0.7 1.6 0.4 2.6 0.4 1.4 0.4 3 0.4 28 13 16 255 18.8 0 19.1 18.5 08/06/2005 09:50:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 16 17 2 255 19.3 0.3 20.3 19.1 08/06/2005 10:00:00 1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 9 28 343 255 20.1 0.2 21.1 20 08/06/2005 10:10:00 1.4 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 3 0.4 15 21 22 255 21.3 0.3 21.7 20.5 08/06/2005 10:20:00 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 1.3 0.7 3 0.4 14 17 11 255 21.6 0.1 22.3 21.1 08/06/2005 10:30:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 357 20 30 255 20.8 0.2 21.1 20.5 08/06/2005 10:40:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 2 76 8 255 20.2 0.1 20.5 20 08/06/2005 10:50:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 357 13 347 255 20.3 0.1 20.8 20 08/06/2005 11:00:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 1 0.7 2.6 0.4 325 39 9 255 21 0 21.1 20.8 08/06/2005 11:10:00 1.8 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.5 1 3.4 0.4 312 47 333 255 21.6 0.2 22 21.1 08/06/2005 11:20:00 1.4 0.8 3 0.4 1.3 0.8 3 0.4 1 0.7 2.6 0.4 258 30 309 255 21.5 0 21.7 21.1 08/06/2005 11:30:00 1.6 0.9 3.4 0.4 1.6 1 3.8 0.4 1.2 0.8 3.8 0.4 277 39 255 255 21.3 0.3 22 20.8 08/06/2005 11:40:00 1.8 0.8 4.2 0.4 1.9 0.7 4.6 0.4 1.5 0.8 3.8 0.4 281 33 279 255 22.1 0 22.6 21.7 08/06/2005 11:50:00 2 0.6 3.8 0.4 1.8 0.6 3.8 0.4 1.3 0.8 3.8 0.4 299 43 299 255 22.7 0 22.9 22.3 08/06/2005 12:00:00 1.8 0.9 3.8 0.4 2 0.9 4.2 0.4 1.5 1 4.2 0.4 269 53 237 255 22.2 0 22.6 22 08/06/2005 12:10:00 1.9 0.7 3.4 0.4 2 0.6 3.4 0.4 1.4 0.7 3 0.4 266 28 239 255 22.1 0 22.6 22 08/06/2005 12:20:00 1.4 0.7 3 0.4 1.6 0.6 3 0.4 1.1 0.5 2.6 0.4 231 47 290 255 21.9 0 22.3 21.7 08/06/2005 12:30:00 1.9 0.5 3.4 0.4 1.9 0.5 3.4 0.4 1.4 0.7 3 0.4 251 19 259 255 21.8 0.2 22.3 21.4 08/06/2005 12:40:00 1.8 1 4.2 0.4 1.9 0.9 3.8 0.4 1.5 1 3.4 0.4 216 27 218 255 21.9 0.2 22.6 21.4 08/06/2005 12:50:00 1.3 0.9 3.4 0.4 1.4 0.9 3.4 0.4 1.1 0.9 3.8 0.4 237 30 247 255 22.8 0.1 23.5 22.3 08/06/2005 13:00:00 1.2 0.9 3 0.4 1.4 0.9 3.4 0.4 1 0.8 3.4 0.4 213 30 195 255 23 0 23.5 22.9 08/06/2005 13:10:00 1.1 0.7 3.4 0.4 1.3 0.7 3.4 0.4 1 0.7 2.6 0.4 200 41 238 255 23.3 0 23.5 23.2 08/06/2005 13:20:00 2.4 0.9 4.6 0.4 2.5 0.8 4.9 0.4 2 1 4.6 0.4 295 27 314 255 23.6 0 23.8 23.5 08/06/2005 13:30:00 1.3 0.8 3 0.4 1.4 0.7 3 0.4 1.1 0.7 3.4 0.4 293 82 313 255 23.9 0.1 24.4 23.8 08/06/2005 13:40:00 2 0.9 3.8 0.4 2.2 0.9 3.8 0.4 1.6 1 3.8 0.4 248 49 224 255 24.3 0.1 24.7 24.1 08/06/2005 13:50:00 1.6 1 4.2 0.4 1.9 1 3.8 0.4 1.4 1 3.8 0.4 241 47 200 255 24.2 0 24.7 24.1 08/06/2005 14:00:00 2.5 0.8 4.6 0.4 2.7 0.8 4.6 0.7 2.1 0.8 3.8 0.4 252 33 255 255 24.4 0 24.7 24.1 08/06/2005 14:10:00 2.3 1 4.6 0.4 2.5 1 4.6 0.4 1.9 1 4.6 0.4 294 33 288 255 24.4 0 24.7 24.1 08/06/2005 14:20:00 2.6 1.1 4.6 0.4 2.7 1 4.6 0.4 2 1.1 4.9 0.4 311 36 312 255 24.7 0.2 25 24.4 08/06/2005 14:30:00 3.5 1.1 5.7 0.4 3.4 1 6.1 0.7 2.6 1.3 5.7 0.4 314 28 304 255 24.7 0.2 25.3 24.4 08/06/2005 14:40:00 2.9 1 5.7 0.4 3 1 5.7 0.4 2.2 1 4.9 0.4 284 27 279 255 24.8 0 25.3 24.4 08/06/2005 14:50:00 2.8 1.1 5.3 0.4 2.8 1.1 5.3 0.4 2.3 1.1 4.9 0.4 277 28 296 255 24.4 0 24.7 24.1 08/06/2005 15:00:00 2.6 1.2 5.3 0.4 2.7 1.2 5.3 0.4 1.9 1.1 4.9 0.4 303 30 321 255 24.7 0.2 25.3 24.4 08/06/2005 15:10:00 4 1 6.5 1.1 4 1 6.5 1.1 3.3 1 5.3 1.1 299 20 316 255 24.5 0.3 25 24.1 08/06/2005 15:20:00 3.9 1 6.1 2.3 3.9 1 6.5 1.9 3.3 1 5.7 0.7 310 14 312 255 24.1 0 24.4 23.8 08/06/2005 15:30:00 2.5 1 4.6 0.4 2.5 1 4.6 0.4 1.8 1 4.2 0.4 302 32 299 255 24.6 0.1 25 24.4 08/06/2005 15:40:00 3.1 0.9 4.9 0.7 3.1 1 4.9 1.1 2.6 1.1 5.3 0.4 298 23 327 255 24.9 0 25.3 24.7 08/06/2005 15:50:00 2.9 1 5.7 0.4 2.9 1 5.3 0.4 2.2 1.1 4.9 0.4 290 21 293 255 24.4 0 24.7 24.4 08/06/2005 16:00:00 3.7 0.9 5.7 0.7 3.6 0.9 5.7 1.1 3.1 1 5.3 0.4 298 21 315 255 24 0.2 24.4 23.8 08/06/2005 16:10:00 3.3 1 6.1 0.7 3.3 1 6.1 1.1 2.5 1 5.7 0.4 293 22 264 255 24 0 24.1 23.8 08/06/2005 16:20:00 3.7 0.8 5.7 1.5 3.7 0.8 5.7 1.9 3.1 1 5.3 0.4 292 20 271 255 23.8 0 24.1 23.8 08/06/2005 16:30:00 3 1.1 5.7 0.4 3 1 5.7 0.7 2.2 1.1 4.9 0.4 303 26 317 255 23.6 0 23.8 23.5 08/06/2005 16:40:00 3.3 1.1 5.7 0.4 3.4 1.1 6.1 0.7 2.7 1.1 5.3 0.4 281 23 301 255 23.3 0 23.5 23.2 08/06/2005 16:50:00 2.8 1 5.3 0.4 3 0.9 5.3 1.1 2.2 1 4.9 0.4 290 22 306 255 22.9 0 23.2 22.9 08/06/2005 17:00:00 3.1 0.8 4.9 1.1 3.2 0.8 4.9 1.1 2.3 1 4.6 0.4 290 21 279 255 22.9 0 23.2 22.9 08/06/2005 17:10:00 3.3 1.1 6.8 0.7 3.3 1.1 6.8 1.1 2.6 1.1 5.7 0.4 290 22 310 255 22.7 0 22.9 22.6 08/06/2005 17:20:00 3.1 1.3 6.1 0.4 3.2 1.2 6.1 1.1 2.3 1.1 4.9 0.4 270 22 271 255 22.7 0 23.2 22.6 08/06/2005 17:30:00 3.7 1 6.5 0.7 3.8 1 6.1 1.5 3.3 1.1 6.1 0.4 291 19 280 255 22.4 0 22.6 22.3 08/06/2005 17:40:00 2.4 1.2 5.3 0.4 2.6 1.1 6.1 0.4 1.7 1.1 4.9 0.4 293 22 328 255 22.1 0 22.3 21.7 08/06/2005 17:50:00 3.1 1.2 6.1 0.4 3.3 1.1 6.5 0.7 2.4 1.2 5.7 0.4 278 26 299 255 21.9 0 22.3 21.7 08/06/2005 18:00:00 3.3 0.9 5.3 0.7 3.4 0.8 5.7 1.5 2.5 1 4.6 0.4 277 22 262 255 21.9 0 22.3 21.7 08/06/2005 18:10:00 3 1 5.7 0.4 3.1 1 5.7 0.7 2.3 1 5.3 0.4 274 27 263 255 21.8 0.1 22.3 21.4 08/06/2005 18:20:00 2.6 1.1 4.9 0.4 2.8 1 5.3 0.4 1.9 1.1 4.6 0.4 278 21 309 255 21.7 0 22 21.4 08/06/2005 18:30:00 3.2 1.1 6.1 0.4 3.3 1.1 6.5 0.7 2.5 1.1 6.1 0.4 279 22 277 255 21.6 0 22 21.4 08/06/2005 18:40:00 2.1 1 5.3 0.4 2.3 1 5.3 0.4 1.7 1 4.2 0.4 284 21 283 255 21.3 0 21.7 21.1 08/06/2005 18:50:00 2.6 1.1 5.3 0.4 2.8 1 6.1 0.7 1.8 1 4.2 0.4 280 22 255 255 21 0 21.4 20.8 08/06/2005 19:00:00 2.4 1.1 5.3 0.4 2.4 1 5.3 0.4 1.8 1.2 5.7 0.4 278 23 289 255 20.8 0 21.4 20.8 08/06/2005 19:10:00 2.7 1 5.3 0.4 2.8 1 5.3 0.4 1.8 1.1 4.9 0.4 278 22 263 255 20.7 0.1 21.1 20.5 08/06/2005 19:20:00 2.7 1 4.9 0.7 2.8 1 4.9 0.4 1.9 1 4.9 0.4 270 17 255 255 20.5 0 21.1 20.3 08/06/2005 19:30:00 3.1 1 5.7 1.1 3.2 1 5.7 1.1 2 1 5.3 0.4 261 19 266 255 20.3 0 20.8 20 08/06/2005 19:40:00 2.9 1.2 6.1 0.4 3.1 1 5.7 0.4 2.1 0.9 4.6 0.4 264 17 274 255 19.9 0 20.3 19.7 08/06/2005 19:50:00 1.9 1.1 5.3 0.4 2.1 1 5.3 0.4 1.3 1 4.6 0.4 267 19 264 255 19.5 0 19.7 19.4 08/06/2005 20:00:00 2.9 1.3 6.1 0.4 3.1 1.2 6.5 0.4 2.1 1.1 5.7 0.4 258 21 273 255 19 0 19.4 18.8 08/06/2005 20:10:00 3.5 1 6.5 0.4 3.6 1 6.1 1.1 2.5 1.1 5.7 0.4 258 23 272 255 18.7 0.1 18.8 18.5 08/06/2005 20:20:00 3 1.2 6.5 0.4 3.2 1.1 6.5 0.4 1.9 1.2 6.8 0.4 264 22 253 255 18.3 0 18.5 18 08/06/2005 20:30:00 3.2 0.8 4.9 1.5 3.3 0.7 4.9 1.1 1.9 1 4.9 0.4 257 17 261 255 17.8 0 18.2 17.4 08/06/2005 20:40:00 2.6 0.8 4.6 0.7 2.7 0.8 4.6 1.1 1.7 0.8 3.8 0.4 250 17 255 255 17.4 0.1 17.7 17.1 08/06/2005 20:50:00 3 0.8 4.9 1.1 3.1 0.8 5.3 1.1 2 0.8 4.2 0.4 245 16 237 255 16.8 0 17.1 16.6 08/06/2005 21:00:00 2.8 0.7 4.6 1.1 3 0.7 4.9 1.1 1.9 0.9 4.2 0.4 249 15 264 255 16.4 0.1 16.8 16.3 08/06/2005 21:10:00 1.2 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.6 0.5 2.6 0.4 259 13 247 255 16 0 16.3 15.7 08/06/2005 21:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 0.4 0 0.4 0.4 257 2 250 255 15.3 0.2 15.7 14.9 08/06/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 258 0 255 255 14.6 0.2 15.2 14.4 08/06/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 258 0 255 255 14 0.1 14.4 13.8 08/06/2005 21:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 258 0 255 255 13.7 0 13.8 13.3 08/06/2005 22:00:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 295 90 83 255 13.4 0 13.8 13 08/06/2005 22:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 57 0 255 255 12.9 0.1 13.3 12.7 08/06/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 57 0 255 255 12.8 0 13 12.7 08/06/2005 22:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 51 11 255 255 12.5 0 12.7 12.5 08/06/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 0 255 255 12.3 0 12.7 12.2 08/06/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 0 255 255 12.3 0 12.5 11.9 08/06/2005 23:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 33 0 255 255 12.1 0.1 12.5 11.9 08/06/2005 23:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 33 0 255 255 11.9 0 12.2 11.9 08/06/2005 23:20:00 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 32 0 32 255 11.7 0 12.2 11.7 08/06/2005 23:30:00 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 32 0 255 255 11.7 0 12.2 11.4 08/06/2005 23:40:00 0.7 0.3 1.1 0.4 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 32 0 32 255 11.6 0 11.9 11.4 08/06/2005 23:50:00 0.4 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 32 0 32 255 11.5 0 11.9 11.4 08/07/2005 00:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 32 0 255 255 11.5 0 11.9 11.4 08/07/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 255 255 11.3 0 11.7 11.1 08/07/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 255 255 11.1 0 11.4 11.1 08/07/2005 00:30:00 0.4 0.1 1.1 0.4 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 52 22 84 255 10.9 0 11.1 10.9 08/07/2005 00:40:00 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 83 0 84 255 10.8 0 10.9 10.9 08/07/2005 00:50:00 0.9 0.6 1.9 0.4 1.1 0.5 2.3 0.4 0.4 0 0.4 0.4 93 14 99 255 10.6 0 10.9 10.6 08/07/2005 01:00:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.1 0.6 0.3 1.1 0.4 106 3 103 255 10.5 0 10.6 10.6 08/07/2005 01:10:00 1.5 0.3 1.9 0.7 1.5 0.3 2.3 1.1 0.6 0.3 1.5 0.4 94 5 101 255 10.4 0 10.6 10.3 08/07/2005 01:20:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 1.1 0.6 0.2 1.1 0.4 79 9 90 255 10.3 0 10.6 10.3 08/07/2005 01:30:00 1.1 0.3 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0.2 1.1 0.4 71 4 68 255 10.2 0 10.3 10.1 08/07/2005 01:40:00 1.1 0.3 1.5 0.4 1.1 0.3 1.9 0.4 0.4 0 0.4 0.4 72 4 69 255 10.1 0 10.3 10.1 08/07/2005 01:50:00 1.6 0.3 2.6 0.7 1.6 0.4 2.6 0.7 0.6 0.3 1.1 0.4 75 3 77 255 10 0 10.3 9.8 08/07/2005 02:00:00 1.2 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 92 13 79 255 9.9 0 10.1 9.8 08/07/2005 02:10:00 0.9 0.4 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 84 9 105 255 9.8 0 10.1 9.8 08/07/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.1 0.5 1.9 0.4 105 20 72 255 9.8 0 9.8 9.8 08/07/2005 02:30:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 1.4 0.4 1.9 0.4 114 13 99 255 9.8 0 9.8 9.6 08/07/2005 02:40:00 1.2 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 105 3 108 255 9.5 0 9.8 9.3 08/07/2005 02:50:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 106 4 105 255 9.5 0 9.6 9.3 08/07/2005 03:00:00 1.5 0.2 1.9 0.7 1.5 0.2 1.9 0.7 0.7 0.4 1.5 0.4 111 5 115 255 9.4 0 9.6 9.3 08/07/2005 03:10:00 1.5 0.3 2.3 0.7 1.4 0.3 1.9 0.7 0.5 0.3 1.5 0.4 92 12 104 255 9.4 0 9.6 9.3 08/07/2005 03:20:00 2 0.3 2.6 1.1 2 0.3 2.6 1.5 0.6 0.3 1.5 0.4 102 8 101 255 9.2 0 9.3 9 08/07/2005 03:30:00 2.1 0.3 3 1.5 2.1 0.3 2.6 1.5 0.9 0.4 1.9 0.4 83 9 83 255 9.1 0 9.3 9 08/07/2005 03:40:00 1.6 0.3 2.6 1.1 1.6 0.4 2.6 0.7 0.6 0.3 1.9 0.4 81 5 74 255 9 0 9 9 08/07/2005 03:50:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 0.6 0.3 1.5 0.4 84 9 94 255 9 0 9 9 08/07/2005 04:00:00 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 0.8 0.4 1.5 0.4 103 7 85 255 8.9 0 9 8.8 08/07/2005 04:10:00 2 0.4 3 1.1 1.9 0.4 2.6 0.7 0.7 0.4 1.5 0.4 113 8 108 255 8.9 0 9 8.8 08/07/2005 04:20:00 1.8 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.2 0.5 2.3 0.4 129 12 133 255 8.9 0 9 8.8 08/07/2005 04:30:00 1.7 0.5 3 0.7 1.7 0.5 2.6 0.4 0.8 0.5 1.9 0.4 120 9 127 255 8.9 0 9 9 08/07/2005 04:40:00 2 0.5 3.4 1.1 2 0.5 3.4 0.7 1.2 0.5 2.6 0.4 122 9 112 255 8.9 0 9 8.8 08/07/2005 04:50:00 2 0.5 3 0.4 1.9 0.5 3 0.7 1.4 0.5 2.3 0.4 127 10 116 255 9 0 9.3 8.8 08/07/2005 05:00:00 2 0.5 3.4 0.7 2 0.5 3.4 0.4 1.1 0.5 2.6 0.4 119 11 108 255 9.1 0 9.3 9 08/07/2005 05:10:00 2 0.6 3.8 0.7 1.9 0.6 3.4 0.4 1.4 0.6 2.6 0.4 126 10 129 255 9.2 0.2 9.6 9 08/07/2005 05:20:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.7 1.5 0.6 3 0.4 124 11 122 255 10 0.2 10.3 9.6 08/07/2005 05:30:00 2.4 0.6 3.8 0.4 2.4 0.6 4.2 0.4 1.6 0.6 3 0.4 125 15 148 255 10.2 0 10.6 10.1 08/07/2005 05:40:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 0.8 0.5 2.6 0.4 118 15 113 255 10.6 0 10.9 10.6 08/07/2005 05:50:00 1.4 0.6 3.4 0.4 1.4 0.7 3 0.4 0.6 0.4 1.9 0.4 116 12 104 255 10.5 0 10.9 10.6 08/07/2005 06:00:00 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 0.7 0.5 2.3 0.4 111 11 97 255 10.5 0 10.6 10.3 08/07/2005 06:10:00 1.9 0.5 3 0.4 1.9 0.5 3 0.4 0.8 0.5 2.3 0.4 110 12 105 255 10.6 0 10.9 10.6 08/07/2005 06:20:00 1.4 0.6 3 0.4 1.4 0.6 2.6 0.4 0.6 0.4 1.9 0.4 116 12 93 255 11.1 0.1 11.4 10.9 08/07/2005 06:30:00 1.2 0.6 2.6 0.4 1.3 0.6 3 0.4 0.6 0.4 2.3 0.4 111 13 93 255 11.6 0 11.9 11.4 08/07/2005 06:40:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 108 11 106 255 11.9 0 12.2 11.7 08/07/2005 06:50:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.5 2.3 0.4 107 14 100 255 12 0 12.2 11.9 08/07/2005 07:00:00 1.6 0.6 2.6 0.4 1.7 0.6 3 0.4 0.9 0.5 2.3 0.4 110 13 111 255 12.3 0.3 13.3 11.9 08/07/2005 07:10:00 2.1 0.4 3 0.7 2.1 0.4 3 0.7 1.4 0.5 2.6 0.4 102 8 100 255 13.3 0.4 14.6 12.7 08/07/2005 07:20:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.4 1.2 0.5 2.3 0.4 100 10 93 255 14.7 0.4 15.7 13.8 08/07/2005 07:30:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 92 15 111 255 15.5 0.3 16.6 15.2 08/07/2005 07:40:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 79 13 71 255 16.6 0 17.1 16.3 08/07/2005 07:50:00 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 63 15 71 255 16.4 0.1 16.8 16.3 08/07/2005 08:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 62 15 56 255 16.2 0.1 16.8 16.3 08/07/2005 08:10:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 75 18 55 255 16.5 0.2 17.1 16.3 08/07/2005 08:20:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 13 5 7 255 17.5 0.1 18 16.8 08/07/2005 08:30:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 16 17 343 255 18.2 0.4 18.8 17.4 08/07/2005 08:40:00 0.5 0.3 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 3 17 358 255 18.5 0.1 18.8 18 08/07/2005 08:50:00 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 7 13 357 255 18 0.2 18.8 17.7 08/07/2005 09:00:00 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 10 17 31 255 19.1 0 19.7 18.8 08/07/2005 09:10:00 0.6 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 2.3 0.4 9 49 272 255 19.7 0.2 20.5 19.1 08/07/2005 09:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 48 21 56 255 19.8 0.2 20.5 19.4 08/07/2005 09:30:00 0.5 0.3 1.9 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.5 0.4 18 38 26 255 19.6 0.2 20.3 19.1 08/07/2005 09:40:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 326 33 309 255 19.9 0 20.3 19.7 08/07/2005 09:50:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 5 39 7 255 20 0.3 20.8 19.4 08/07/2005 10:00:00 1 0.7 3 0.4 1.1 0.7 3 0.4 0.8 0.5 2.6 0.4 294 33 256 255 20.7 0.2 21.4 20.5 08/07/2005 10:10:00 1.1 0.6 3 0.4 1.3 0.6 3 0.4 1 0.6 2.6 0.4 18 14 17 255 21 0.3 21.7 20.5 08/07/2005 10:20:00 0.8 0.6 3 0.4 1 0.6 3 0.4 0.9 0.6 2.6 0.4 3 35 40 255 21.6 0 21.7 21.4 08/07/2005 10:30:00 0.4 0.3 1.9 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.9 0.4 48 76 118 255 21.6 0 21.7 21.4 08/07/2005 10:40:00 1.5 0.7 3 0.4 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 43 33 18 255 21.6 0 22 21.1 08/07/2005 10:50:00 2.1 1 4.2 0.4 2.1 0.9 4.2 0.4 1.9 1 4.6 0.4 346 26 7 255 21.7 0.1 22.3 21.4 08/07/2005 11:00:00 1.8 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.6 0.6 3 0.4 348 20 346 255 22 0.2 22.9 21.7 08/07/2005 11:10:00 0.8 0.6 3 0.4 1 0.6 3 0.4 0.8 0.5 2.6 0.4 253 56 326 255 22.4 0.2 23.2 22 08/07/2005 11:20:00 1.7 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.5 0.6 3 0.4 293 26 296 255 22.3 0 22.6 22 08/07/2005 11:30:00 1.1 0.7 3 0.4 1.2 0.7 3 0.4 1 0.6 2.6 0.4 242 61 256 255 22.1 0 22.3 22 08/07/2005 11:40:00 1.4 0.8 4.2 0.4 1.5 0.8 4.2 0.4 1.3 0.9 3.8 0.4 294 26 299 255 22.4 0 22.9 22.3 08/07/2005 11:50:00 1.8 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.9 3.4 0.4 293 33 322 255 22.7 0.3 23.2 22.3 08/07/2005 12:00:00 1.6 1 4.9 0.4 1.8 0.9 4.6 0.4 1.5 0.9 3.8 0.4 233 32 255 255 22.9 0 23.2 22.9 08/07/2005 12:10:00 1.4 1.1 4.2 0.4 1.7 1 4.2 0.4 1.3 1 4.2 0.4 235 32 251 255 22.7 0 22.9 22.6 08/07/2005 12:20:00 1.7 0.7 3.8 0.4 1.9 0.7 4.2 0.4 1.5 0.6 3 0.4 256 33 255 255 22.6 0 22.6 22.6 08/07/2005 12:30:00 2.2 0.9 4.6 0.4 2.4 0.9 4.6 0.7 1.9 1 4.9 0.4 310 24 294 255 22.6 0 22.9 22.3 08/07/2005 12:40:00 2.6 0.7 4.6 0.7 2.7 0.7 4.2 1.1 2.1 0.9 4.2 0.4 297 22 315 255 22.4 0 22.6 22 08/07/2005 12:50:00 2.3 0.8 3.8 0.4 2.4 0.7 4.2 0.7 1.8 0.8 3.8 0.4 297 26 293 255 22.2 0 22.6 22 08/07/2005 13:00:00 3.2 0.9 4.9 1.1 3.3 0.9 5.3 1.1 2.7 0.9 4.9 0.7 290 18 297 255 22.8 0.1 23.2 22.6 08/07/2005 13:10:00 3 0.9 4.9 0.4 3.2 0.9 5.3 0.7 2.7 0.8 4.9 1.1 289 19 276 255 23 0 23.5 22.6 08/07/2005 13:20:00 2.9 0.8 5.3 0.4 3 0.7 4.9 1.1 2.6 0.9 4.9 0.7 306 14 286 255 23.5 0 23.8 23.2 08/07/2005 13:30:00 2.5 1 4.6 0.4 2.5 1 4.6 0.4 2.1 1 4.6 0.4 311 20 310 255 23.1 0 23.5 22.9 08/07/2005 13:40:00 2.8 0.9 5.3 0.4 2.9 1 5.7 0.4 2.5 0.8 4.9 0.4 275 26 310 255 23 0.1 23.5 22.6 08/07/2005 13:50:00 2.8 0.9 4.9 0.4 2.9 0.9 5.3 0.7 2.4 0.8 5.3 0.4 268 27 296 255 22.5 0.1 22.9 22.3 08/07/2005 14:00:00 2.8 1.1 5.3 0.4 3 1.1 5.7 0.4 2.4 1 4.9 0.4 278 21 285 255 22.3 0 22.6 22.3 08/07/2005 14:10:00 3 1 5.3 0.4 3.1 1 5.3 0.7 2.4 1 5.3 0.4 279 22 278 255 22.1 0.1 22.6 21.7 08/07/2005 14:20:00 2.8 0.9 5.3 1.1 2.9 0.8 4.9 1.1 2.3 0.8 4.6 0.4 285 20 294 255 22 0 22.3 22 08/07/2005 14:30:00 2.9 0.9 5.3 0.7 3 0.9 5.3 0.7 2.3 1 4.9 0.4 287 16 281 255 22 0 22.3 22 08/07/2005 14:40:00 2.9 0.8 4.9 0.7 3 0.8 4.9 1.1 2.4 1 4.9 0.4 289 21 288 255 21.9 0.1 22.3 21.7 08/07/2005 14:50:00 2.5 1.1 4.6 0.4 2.7 1 4.9 0.7 2 1 4.2 0.4 297 21 318 255 21.7 0 21.7 21.7 08/07/2005 15:00:00 2.4 1 4.6 0.4 2.5 0.9 4.6 0.4 2.1 1 4.2 0.4 304 20 289 255 22 0 22.3 21.7 08/07/2005 15:10:00 2.3 1 4.6 0.4 2.4 1 4.9 0.4 1.4 0.8 4.2 0.4 310 20 300 255 22.6 0.2 22.9 22.3 08/07/2005 15:20:00 2.9 0.8 4.9 0.7 3 0.7 5.3 1.1 2.6 0.8 5.3 0.7 301 17 301 255 22.4 0.2 22.9 22 08/07/2005 15:30:00 2.4 0.9 4.2 0.4 2.6 0.8 4.6 0.7 1.9 1 4.2 0.4 298 18 271 255 21.9 0 22 21.7 08/07/2005 15:40:00 2.3 0.8 4.2 0.4 2.5 0.7 4.2 0.7 1.7 0.9 3.4 0.4 303 21 343 255 22.4 0 22.6 22 08/07/2005 15:50:00 2.5 0.8 4.2 0.4 2.6 0.8 4.2 0.7 2 0.9 4.6 0.4 303 23 303 255 23 0.2 23.8 22.6 08/07/2005 16:00:00 2.1 1.2 4.9 0.4 2.2 1.2 4.9 0.4 1.7 1.2 4.6 0.4 313 35 312 255 23.9 0 24.4 23.8 08/07/2005 16:10:00 2.4 1.2 4.9 0.4 2.5 1.2 4.9 0.4 1.9 1.2 4.9 0.4 301 22 272 255 23.6 0.3 24.4 23.2 08/07/2005 16:20:00 2.4 0.8 4.2 0.4 2.6 0.7 4.6 1.1 2.2 0.8 3.8 0.4 289 22 267 255 22.8 0 23.2 22.6 08/07/2005 16:30:00 2.5 0.9 4.2 0.4 2.7 0.7 4.2 0.7 2 1 4.2 0.4 295 21 290 255 22.7 0 22.9 22.3 08/07/2005 16:40:00 3.1 0.7 4.6 1.5 3.2 0.7 4.6 1.5 2.6 0.9 4.6 0.4 295 13 309 255 22.3 0 22.9 22 08/07/2005 16:50:00 2.2 0.8 3.8 0.4 2.5 0.7 3.8 1.1 1.9 0.9 3.8 0.4 291 19 301 255 22.3 0.1 22.9 22.3 08/07/2005 17:00:00 2 1.2 4.2 0.4 2.3 1.1 4.2 0.4 1.6 1.1 4.2 0.4 312 28 291 255 22.4 0 22.9 22.3 08/07/2005 17:10:00 2.7 0.7 4.2 1.1 2.8 0.7 4.2 1.1 2.1 0.9 4.2 0.4 307 13 305 255 22.2 0 22.6 22 08/07/2005 17:20:00 3.3 0.8 4.9 1.1 3.4 0.7 4.9 1.5 2.4 0.9 4.6 0.4 309 15 314 255 21.9 0.1 22.6 21.7 08/07/2005 17:30:00 1.9 0.8 4.2 0.4 2.2 0.7 4.2 0.7 1.3 0.8 3.8 0.4 304 16 318 255 21.6 0 21.7 21.7 08/07/2005 17:40:00 2.3 0.8 3.8 0.4 2.5 0.7 3.8 0.7 1.9 0.9 3.8 0.4 306 14 294 255 21.9 0 22.3 21.7 08/07/2005 17:50:00 2.1 1.1 4.2 0.4 2.3 1 4.2 0.4 1.6 0.9 3.4 0.4 307 15 320 255 22 0 22.3 21.7 08/07/2005 18:00:00 2 0.8 4.2 0.4 2.2 0.7 3.8 0.4 1.6 0.8 3.8 0.4 278 19 286 255 22 0 22.3 21.7 08/07/2005 18:10:00 1.9 0.8 3.8 0.4 2.1 0.8 3.8 0.4 1.5 0.8 3 0.4 296 21 280 255 21.9 0 22.3 21.7 08/07/2005 18:20:00 2.5 0.7 4.2 0.4 2.6 0.7 4.2 0.4 1.9 0.8 3.8 0.4 279 17 255 255 22 0.1 22.3 21.7 08/07/2005 18:30:00 2.1 1 4.6 0.4 2.3 0.8 4.6 0.7 1.7 1.1 4.6 0.4 292 17 298 255 21.6 0.1 22.3 21.1 08/07/2005 18:40:00 2 0.8 3.8 0.4 2.2 0.7 3.4 0.7 1.4 0.8 3.4 0.4 297 17 269 255 21.3 0 21.7 21.1 08/07/2005 18:50:00 1.6 0.6 3 0.4 1.7 0.5 3 0.4 1 0.6 3 0.4 293 13 293 255 21.1 0 21.1 21.1 08/07/2005 19:00:00 1.6 0.6 2.6 0.4 1.7 0.5 2.6 0.4 1.1 0.7 3 0.4 276 19 282 255 21.1 0 21.7 21.1 08/07/2005 19:10:00 1.2 0.7 2.6 0.4 1.3 0.7 2.6 0.4 0.9 0.5 2.3 0.4 261 15 260 255 21 0.1 21.4 20.8 08/07/2005 19:20:00 1.4 0.8 3.4 0.4 1.6 0.7 3.4 0.4 0.9 0.6 2.6 0.4 272 17 267 255 20.5 0.1 21.1 20 08/07/2005 19:30:00 1 0.5 2.6 0.4 1.2 0.5 3 0.4 0.4 0.2 1.5 0.4 263 9 267 255 19.7 0.2 20.5 19.4 08/07/2005 19:40:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 261 9 255 255 19.1 0 19.7 18.8 08/07/2005 19:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 274 1 255 255 18.9 0 19.1 18.5 08/07/2005 20:00:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 262 12 255 255 18.6 0 18.8 18.5 08/07/2005 20:10:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 289 14 299 255 18.4 0 18.5 18.2 08/07/2005 20:20:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 305 17 317 255 18 0 18.2 17.7 08/07/2005 20:30:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 263 7 262 255 17.5 0.1 17.7 17.1 08/07/2005 20:40:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 268 2 267 255 17.1 0 17.4 16.8 08/07/2005 20:50:00 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 268 0 268 255 16.7 0 16.8 16.6 08/07/2005 21:00:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 271 17 267 255 16.2 0 16.8 16 08/07/2005 21:10:00 1.3 0.6 2.6 0.4 1.6 0.5 2.6 0.4 0.5 0.2 1.5 0.4 12 15 10 255 15.7 0.1 16.3 15.5 08/07/2005 21:20:00 1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.5 0.3 1.5 0.4 31 7 33 255 15.2 0.1 15.7 14.9 08/07/2005 21:30:00 1.2 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 49 10 51 255 14.8 0.1 15.2 14.6 08/07/2005 21:40:00 0.9 0.3 1.5 0.4 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 44 5 40 255 14.7 0 15.2 14.4 08/07/2005 21:50:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 48 5 43 255 14.3 0.2 14.9 13.8 08/07/2005 22:00:00 1.3 0.4 1.9 0.4 1.3 0.3 1.9 0.4 0.6 0.3 1.5 0.4 59 5 60 255 13.9 0.1 14.6 13.5 08/07/2005 22:10:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1 0.4 1.9 0.4 56 12 49 255 13.5 0.1 14.1 13.3 08/07/2005 22:20:00 0.8 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.4 0.2 1.5 0.4 46 16 43 255 13.1 0.2 13.8 13 08/07/2005 22:30:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 60 6 49 255 12.9 0 13.3 12.7 08/07/2005 22:40:00 1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.6 0.5 2.3 0.4 68 15 47 255 12.8 0 13.3 12.7 08/07/2005 22:50:00 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 81 11 90 255 12.6 0 13 12.5 08/07/2005 23:00:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.8 0.3 1.5 0.4 61 10 69 255 12.4 0 12.7 12.2 08/07/2005 23:10:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.5 0.2 1.1 0.4 60 6 54 255 12.1 0 12.5 11.9 08/07/2005 23:20:00 1.4 0.4 2.6 0.4 1.4 0.4 2.6 0.4 0.6 0.4 2.3 0.4 61 7 58 255 12 0 12.5 11.9 08/07/2005 23:30:00 1.7 0.5 3 0.4 1.6 0.5 2.6 0.4 0.8 0.4 1.9 0.4 74 11 76 255 12 0 12.5 11.9 08/07/2005 23:40:00 1.7 0.8 3.4 0.4 1.8 0.7 3.4 0.4 0.9 0.5 2.3 0.4 69 13 106 255 11.9 0.1 12.5 11.7 08/07/2005 23:50:00 1.2 0.5 3 0.4 1.1 0.5 3 0.4 0.5 0.4 2.3 0.4 69 9 46 255 12.1 0 12.5 11.9 08/08/2005 00:00:00 1.2 0.3 2.3 0.4 1.2 0.4 1.9 0.4 0.5 0.2 1.1 0.4 69 4 57 255 12 0 12.2 11.9 08/08/2005 00:10:00 1.2 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0 0.7 0.4 78 2 82 255 12 0 12.2 11.9 08/08/2005 00:20:00 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 88 11 107 255 11.7 0 11.9 11.7 08/08/2005 00:30:00 2 0.4 3 1.1 2 0.4 3 0.7 1 0.4 1.9 0.4 108 8 102 255 11.5 0 11.7 11.4 08/08/2005 00:40:00 1.8 0.4 2.6 1.1 1.8 0.4 2.6 0.7 0.5 0.3 1.5 0.4 101 7 94 255 11.3 0 11.7 11.1 08/08/2005 00:50:00 1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.4 0 0.7 0.4 90 6 111 255 11.3 0.1 11.7 11.1 08/08/2005 01:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 90 0 90 255 11.3 0 11.7 11.1 08/08/2005 01:10:00 1.5 0.3 2.3 1.1 1.4 0.3 2.3 0.7 0.4 0.1 1.1 0.4 100 11 113 255 11.1 0 11.7 10.9 08/08/2005 01:20:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 1 0.3 1.9 0.4 112 6 122 255 10.9 0 11.1 10.9 08/08/2005 01:30:00 2.6 0.4 3.4 1.9 2.7 0.4 3.4 1.5 1.4 0.4 2.6 0.4 110 6 121 255 10.9 0 11.1 10.9 08/08/2005 01:40:00 2.3 0.5 3.4 0.7 2.4 0.5 3.4 1.1 1.1 0.5 2.3 0.4 114 7 103 255 10.7 0 10.9 10.6 08/08/2005 01:50:00 1.8 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.1 0.4 2.3 0.4 124 10 124 255 10.6 0 10.9 10.6 08/08/2005 02:00:00 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 123 11 106 255 10.6 0 11.1 10.6 08/08/2005 02:10:00 1.9 0.7 3.4 0.4 2 0.6 3.4 0.4 1.1 0.5 2.3 0.4 121 11 116 255 10.6 0 10.9 10.6 08/08/2005 02:20:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 0.8 0.5 2.6 0.4 114 11 108 255 10.7 0 10.9 10.6 08/08/2005 02:30:00 2 0.4 3 1.1 2.1 0.4 3 1.1 0.6 0.3 1.9 0.4 102 7 110 255 10.6 0 10.9 10.6 08/08/2005 02:40:00 1.8 0.4 2.6 0.7 2 0.4 3 0.7 0.6 0.4 1.9 0.4 106 11 96 255 10.6 0 10.6 10.6 08/08/2005 02:50:00 1.3 0.5 2.6 0.4 1.5 0.4 2.6 0.4 0.5 0.2 1.5 0.4 111 14 115 255 10.5 0 10.6 10.6 08/08/2005 03:00:00 1.8 0.5 3 0.4 1.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 113 8 136 255 10.6 0 10.6 10.6 08/08/2005 03:10:00 2.7 0.5 3.8 1.1 2.8 0.4 3.8 1.1 1.5 0.6 2.6 0.4 105 8 109 255 10.5 0 10.6 10.6 08/08/2005 03:20:00 2.6 0.3 3.4 1.5 2.8 0.3 3.4 1.9 1.6 0.5 2.6 0.4 104 6 93 255 10.5 0 10.6 10.6 08/08/2005 03:30:00 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.5 1.4 0.5 2.6 0.4 110 8 104 255 10.4 0 10.6 10.3 08/08/2005 03:40:00 2.3 0.5 3.4 0.7 2.3 0.5 3.4 1.1 1 0.5 2.3 0.4 108 9 113 255 10.5 0 10.6 10.3 08/08/2005 03:50:00 2.2 0.4 3 0.7 2.3 0.4 3.4 0.7 1 0.6 2.6 0.4 106 8 95 255 10.5 0 10.6 10.3 08/08/2005 04:00:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.1 0.6 2.6 0.4 107 8 96 255 10.5 0 10.6 10.6 08/08/2005 04:10:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 1.1 0.5 2.6 0.4 106 7 108 255 10.6 0 10.9 10.6 08/08/2005 04:20:00 2.3 0.5 3.4 0.7 2.4 0.5 3.4 1.1 1.1 0.5 2.3 0.4 107 10 94 255 10.7 0 10.9 10.6 08/08/2005 04:30:00 2 0.5 3.4 0.4 2.1 0.5 3.4 1.1 0.7 0.4 1.9 0.4 110 12 106 255 11 0 11.1 10.9 08/08/2005 04:40:00 1.8 0.6 3 0.4 1.9 0.5 3.4 0.4 0.6 0.4 1.9 0.4 113 10 113 255 11.1 0 11.4 11.1 08/08/2005 04:50:00 1.9 0.6 3.4 0.4 2 0.6 3.4 0.4 0.6 0.4 2.3 0.4 111 13 102 255 11.3 0 11.4 11.1 08/08/2005 05:00:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 106 13 126 255 11.3 0.1 11.4 11.4 08/08/2005 05:10:00 1.1 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.4 0.1 1.1 0.4 85 9 88 255 11.3 0 11.7 11.1 08/08/2005 05:20:00 1.7 0.7 3 0.4 1.8 0.6 3 0.7 0.8 0.6 2.6 0.4 73 10 84 255 11.5 0 11.7 11.4 08/08/2005 05:30:00 2.7 0.4 3.4 1.5 2.9 0.4 3.4 1.5 1.7 0.5 2.6 0.4 90 6 92 255 11.6 0 11.7 11.7 08/08/2005 05:40:00 2.6 0.4 3.8 1.1 2.7 0.4 3.8 1.9 1.5 0.6 2.6 0.4 95 8 92 255 11.9 0.1 11.9 11.7 08/08/2005 05:50:00 2.2 0.5 3.4 0.4 2.3 0.5 3.4 0.4 1.2 0.6 2.6 0.4 104 12 94 255 12.1 0 12.2 11.9 08/08/2005 06:00:00 1.5 0.7 3 0.4 1.7 0.6 3 0.4 0.6 0.4 2.3 0.4 115 13 132 255 12.3 0 12.2 12.2 08/08/2005 06:10:00 1.5 0.6 3 0.4 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 121 15 123 255 12.3 0 12.5 12.2 08/08/2005 06:20:00 1.3 0.6 2.6 0.4 1.4 0.6 3 0.4 0.7 0.5 2.3 0.4 127 11 118 255 12.7 0 12.7 12.5 08/08/2005 06:30:00 0.9 0.6 2.6 0.4 1 0.6 2.3 0.4 0.5 0.2 1.5 0.4 119 12 119 255 13 0 13.3 12.7 08/08/2005 06:40:00 1.1 0.6 3 0.4 1.2 0.6 3 0.4 0.6 0.4 2.3 0.4 113 14 98 255 13.4 0 13.8 13.3 08/08/2005 06:50:00 1.6 0.5 2.6 0.4 1.7 0.5 3 0.4 0.7 0.5 2.3 0.4 101 8 107 255 13.8 0 14.6 13.5 08/08/2005 07:00:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 0.5 0.3 1.9 0.4 78 13 89 255 14.4 0.3 15.5 13.8 08/08/2005 07:10:00 0.7 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.5 0.4 1.9 0.4 77 15 83 255 15.4 0.2 16.3 14.9 08/08/2005 07:20:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 84 13 84 255 15.8 0.1 16.3 15.7 08/08/2005 07:30:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 95 17 89 255 15.9 0 16.3 15.7 08/08/2005 07:40:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 88 15 93 255 15.9 0 16.3 15.7 08/08/2005 07:50:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 101 13 96 255 16.1 0 16.8 16 08/08/2005 08:00:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 83 9 78 255 16.6 0 17.1 16.3 08/08/2005 08:10:00 1.3 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.8 0.5 2.3 0.4 80 17 92 255 17.1 0.1 17.7 16.8 08/08/2005 08:20:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 37 15 62 255 17.5 0 18 17.1 08/08/2005 08:30:00 1.5 0.7 3 0.4 1.6 0.6 3 0.4 1.1 0.7 2.6 0.4 50 17 33 255 17.7 0 18.2 17.4 08/08/2005 08:40:00 1.6 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.2 0.6 2.6 0.4 39 18 21 255 18 0 18.5 18 08/08/2005 08:50:00 1.6 0.7 3.8 0.4 1.7 0.7 3.4 0.4 1.1 0.7 3.4 0.4 42 13 51 255 18 0 18.2 17.7 08/08/2005 09:00:00 3 0.8 4.6 0.7 3.1 0.8 4.6 0.7 2.5 0.9 4.2 0.4 48 13 43 255 17.5 0.2 18 17.1 08/08/2005 09:10:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 0.9 0.5 2.3 0.4 16 16 12 255 17.4 0 17.7 17.1 08/08/2005 09:20:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.4 1.9 0.4 9 17 339 255 17.8 0 18 17.7 08/08/2005 09:30:00 0.8 0.4 1.9 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 13 14 11 255 17.7 0 17.7 17.4 08/08/2005 09:40:00 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.5 2.3 0.4 7 13 14 255 17.8 0 18 17.7 08/08/2005 09:50:00 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 348 28 4 255 18.2 0 18.2 18 08/08/2005 10:00:00 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 2 15 12 255 18.2 0 18.2 18 08/08/2005 10:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 329 22 329 255 18.2 0 18.2 18 08/08/2005 10:20:00 0.4 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.3 1.9 0.4 354 15 19 255 18.1 0.1 18.5 18 08/08/2005 10:30:00 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0 15 0 255 18.6 0 19.1 18.2 08/08/2005 10:40:00 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 2 26 2 255 18.8 0 19.4 18.5 08/08/2005 10:50:00 0.4 0.2 1.5 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 51 41 64 255 18.7 0.1 19.4 18.5 08/08/2005 11:00:00 0.4 0.3 2.6 0.4 0.7 0.5 2.6 0.4 0.4 0.2 1.5 0.4 6 51 10 255 19.7 0.4 20.5 18.8 08/08/2005 11:10:00 0.8 0.5 2.3 0.4 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 27 29 14 255 20.3 0 20.8 20 08/08/2005 11:20:00 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 78 36 28 255 20.6 0.2 21.1 20.3 08/08/2005 11:30:00 1 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 29 41 343 255 21.3 0 21.7 21.1 08/08/2005 11:40:00 1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 53 21 21 255 20.9 0 21.1 20.8 08/08/2005 11:50:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 3 33 39 255 20.9 0 21.1 20.5 08/08/2005 12:00:00 1.3 0.7 3 0.4 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 1 17 356 255 20.8 0.1 21.1 20.5 08/08/2005 12:10:00 2.3 0.5 3.4 1.1 2.3 0.5 3.8 1.1 1.9 0.6 3.4 0.4 352 16 338 255 21.5 0.5 22.6 20.8 08/08/2005 12:20:00 1.9 0.8 3.4 0.4 1.9 0.7 3.4 0.4 1.5 0.7 3.4 0.4 355 22 336 255 22.7 0 22.9 22.6 08/08/2005 12:30:00 1.5 0.6 3.8 0.4 1.8 0.5 3.8 0.7 1.4 0.6 3 0.4 26 18 30 255 23 0 23.5 22.9 08/08/2005 12:40:00 1.7 0.6 4.2 0.4 1.9 0.6 4.2 0.4 1.6 0.7 3.4 0.4 19 35 11 255 23.2 0 23.8 22.9 08/08/2005 12:50:00 1.7 0.7 3.4 0.4 2 0.6 3.4 0.4 1.5 0.6 3 0.4 8 17 39 255 23.4 0.1 23.8 23.2 08/08/2005 13:00:00 1.6 0.5 2.6 0.4 1.8 0.5 3 0.7 1.4 0.6 3 0.4 25 23 27 255 23.3 0 23.5 23.2 08/08/2005 13:10:00 1.6 0.8 3.4 0.4 1.9 0.7 3.4 0.4 1.6 0.7 3.4 0.4 34 35 68 255 23.4 0 23.8 23.2 08/08/2005 13:20:00 1.6 0.9 4.2 0.4 1.9 0.8 4.2 0.4 1.6 0.8 3.4 0.4 23 38 10 255 23.5 0 23.8 23.5 08/08/2005 13:30:00 1.4 0.8 3.4 0.4 1.8 0.6 3.4 0.7 1.6 0.6 3 0.4 6 33 309 255 24 0.1 24.4 23.8 08/08/2005 13:40:00 2.1 0.7 3.8 0.7 2.2 0.6 4.2 0.7 1.7 0.7 3.4 0.4 348 22 0 255 24.1 0 24.4 23.8 08/08/2005 13:50:00 1.7 0.8 3.8 0.4 1.9 0.7 3.8 0.4 1.6 0.9 3.8 0.4 345 20 347 255 24.4 0 24.7 24.4 08/08/2005 14:00:00 1.5 0.9 3.8 0.4 1.8 0.8 3.8 0.4 1.2 0.8 3 0.4 13 35 29 255 24.7 0 25 24.4 08/08/2005 14:10:00 0.9 0.5 2.3 0.4 1.3 0.6 3 0.4 1.1 0.5 2.6 0.4 28 22 9 255 24.7 0 25 24.4 08/08/2005 14:20:00 1.4 0.8 3 0.4 1.7 0.5 3 0.4 1.5 0.6 3 0.4 2 24 328 255 24.6 0 25 24.4 08/08/2005 14:30:00 1.4 0.8 3 0.4 1.7 0.8 3.4 0.4 1.5 0.8 3.4 0.4 331 49 320 255 24.6 0.1 25 24.4 08/08/2005 14:40:00 1.4 1 4.2 0.4 1.7 0.9 4.6 0.4 1.4 0.9 3.8 0.4 322 29 306 255 24.6 0 25 24.4 08/08/2005 14:50:00 2.1 0.9 3.8 0.4 2.3 0.9 4.2 0.4 1.8 0.9 3.8 0.4 359 32 16 255 24.5 0 25 24.4 08/08/2005 15:00:00 2.3 1 4.6 0.4 2.6 0.9 4.6 0.4 1.9 1 4.2 0.4 11 17 27 255 24.4 0 24.7 24.1 08/08/2005 15:10:00 2 0.6 3.8 0.4 2.3 0.6 4.2 0.7 1.6 0.6 3.4 0.4 15 16 12 255 24.4 0 24.7 24.4 08/08/2005 15:20:00 2.1 0.7 3.4 0.4 2.4 0.6 3.8 0.7 1.5 0.7 3 0.4 5 19 355 255 24.6 0 25 24.4 08/08/2005 15:30:00 2.1 0.7 3.4 0.4 2.3 0.7 4.2 0.7 1.7 0.7 3 0.4 346 17 348 255 24.4 0 24.7 24.4 08/08/2005 15:40:00 1.8 0.9 3.4 0.4 2.1 0.8 3.4 0.4 1.6 0.8 3.8 0.4 1 23 27 255 24.5 0 25 24.4 08/08/2005 15:50:00 1.6 0.7 3 0.4 2 0.6 3.4 0.4 1.5 0.6 3.4 0.4 24 18 33 255 24.5 0 24.7 24.4 08/08/2005 16:00:00 1.8 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.3 0.6 2.6 0.4 347 18 332 255 25 0.1 25.3 24.7 08/08/2005 16:10:00 1.5 0.8 3.8 0.4 1.8 0.6 3.8 0.4 1.3 0.5 2.6 0.4 358 17 14 255 25 0 25.3 24.7 08/08/2005 16:20:00 1.3 0.6 2.6 0.4 1.7 0.5 2.6 0.7 1.2 0.6 2.6 0.4 17 20 20 255 24.6 0 25 24.4 08/08/2005 16:30:00 2 0.8 3.8 0.4 2.2 0.7 3.8 0.7 1.6 0.9 3.4 0.4 358 21 352 255 24.4 0 24.7 24.4 08/08/2005 16:40:00 1.8 0.9 3.4 0.4 2.1 0.8 3.8 0.4 1.3 0.7 3 0.4 13 23 21 255 24.4 0 24.7 24.4 08/08/2005 16:50:00 1.7 0.8 3.4 0.4 1.8 0.6 3.4 0.4 1.3 0.8 3 0.4 347 17 358 255 24.4 0 24.7 24.1 08/08/2005 17:00:00 2.2 0.6 3.8 0.7 2.5 0.5 3.8 1.1 1.6 0.6 3 0.4 6 11 43 255 24.1 0 24.1 23.8 08/08/2005 17:10:00 1.8 0.6 3.4 0.4 2.1 0.5 3.4 0.7 1.2 0.6 3 0.4 4 13 12 255 23.9 0 24.4 23.8 08/08/2005 17:20:00 2.1 0.8 3.8 0.4 2.3 0.7 3.8 0.7 1.6 0.8 3 0.4 12 23 10 255 23.8 0 24.1 23.8 08/08/2005 17:30:00 3 0.4 3.8 1.5 3 0.4 3.8 1.9 2.6 0.5 3.8 1.5 25 8 27 255 23.8 0 24.1 23.5 08/08/2005 17:40:00 2.6 0.4 3.8 1.5 2.7 0.4 3.8 1.9 1.9 0.7 3 0.4 13 15 1 255 23.5 0.1 24.1 23.5 08/08/2005 17:50:00 1.9 0.8 3.4 0.4 2.2 0.6 3.4 0.4 1.4 0.9 3 0.4 17 16 20 255 23.5 0 23.8 23.5 08/08/2005 18:00:00 2.5 0.5 3.4 0.7 2.7 0.5 3.8 1.1 2.1 0.7 3.4 0.4 32 13 32 255 23.2 0.1 23.5 22.9 08/08/2005 18:10:00 1.7 0.6 3 0.4 2.1 0.6 3 0.4 1.5 0.8 3 0.4 23 13 23 255 22.7 0 22.9 22.9 08/08/2005 18:20:00 2.2 0.6 3.8 0.4 2.4 0.6 4.2 0.7 1.2 0.7 3 0.4 9 13 7 255 22.7 0 22.9 22.6 08/08/2005 18:30:00 1.2 0.7 3.4 0.4 1.7 0.6 3.4 0.4 0.9 0.6 2.6 0.4 13 11 5 255 22.7 0 22.9 22.6 08/08/2005 18:40:00 2.1 0.7 3.8 0.4 2.4 0.6 3.8 1.1 1.5 0.8 3.4 0.4 21 13 14 255 22.5 0 22.9 22.3 08/08/2005 18:50:00 2.3 0.7 3.4 0.4 2.6 0.6 3.8 0.7 2 0.7 3.4 0.4 27 12 37 255 22.2 0 22.6 22 08/08/2005 19:00:00 1.7 0.7 3 0.4 2.1 0.6 3.4 0.4 1.4 0.7 3 0.4 27 10 26 255 22.1 0 22.3 22 08/08/2005 19:10:00 0.7 0.5 2.3 0.4 1.3 0.6 3 0.4 0.9 0.5 2.3 0.4 59 15 61 255 22 0 22.3 21.7 08/08/2005 19:20:00 1.6 0.7 2.6 0.4 2.1 0.5 3 0.7 1.6 0.6 3 0.4 60 11 67 255 21.9 0.1 22.3 21.7 08/08/2005 19:30:00 1.9 0.8 3.8 0.4 2.2 0.6 3.8 0.7 1.7 0.6 3 0.4 54 15 62 255 21.6 0 22 21.1 08/08/2005 19:40:00 1.7 0.8 3.4 0.4 2 0.7 3.8 0.4 1.4 0.7 3.4 0.4 59 14 56 255 21.3 0 21.7 21.1 08/08/2005 19:50:00 1.2 0.6 2.6 0.4 1.6 0.5 2.6 0.4 1 0.5 2.3 0.4 70 15 61 255 20.8 0.2 21.4 20.5 08/08/2005 20:00:00 1.4 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1 0.6 2.6 0.4 55 21 55 255 20.5 0 21.1 20.3 08/08/2005 20:10:00 1 0.5 2.3 0.4 1.4 0.4 2.6 0.4 0.7 0.4 1.5 0.4 71 8 77 255 20 0.1 20.8 19.7 08/08/2005 20:20:00 1.2 0.6 2.6 0.4 1.4 0.6 3 0.4 0.9 0.5 2.3 0.4 60 17 55 255 19.5 0.1 20.3 19.4 08/08/2005 20:30:00 2.1 0.5 3.4 0.4 2.3 0.5 3.4 1.1 1.8 0.5 3 0.4 61 13 56 255 19.4 0 20 19.1 08/08/2005 20:40:00 1 0.6 2.6 0.4 1.5 0.6 3 0.4 1 0.6 2.3 0.4 64 17 50 255 19.5 0 20 19.4 08/08/2005 20:50:00 1.7 0.7 3.4 0.4 2.1 0.5 3.4 1.1 1.3 0.7 3.4 0.4 69 16 84 255 19.2 0 19.4 19.1 08/08/2005 21:00:00 1.4 0.7 3.4 0.4 1.9 0.6 3.8 0.4 1 0.6 2.6 0.4 60 15 59 255 18.9 0 19.1 18.5 08/08/2005 21:10:00 1.8 0.8 3.4 0.4 2.2 0.6 3.8 0.7 1.4 0.7 3 0.4 68 13 55 255 18.4 0 18.5 18.2 08/08/2005 21:20:00 1.7 0.8 3.8 0.4 2.1 0.6 3.8 0.7 1.5 0.6 3 0.4 66 14 70 255 17.8 0.1 18.2 17.4 08/08/2005 21:30:00 2 0.6 3.4 0.4 2.2 0.5 3.8 1.1 1.3 0.6 3.4 0.4 71 12 63 255 17.2 0.1 17.7 16.8 08/08/2005 21:40:00 2.1 0.5 3.8 0.7 2.3 0.5 3.4 1.1 1.5 0.5 2.6 0.4 70 12 76 255 16.3 0.2 16.8 16 08/08/2005 21:50:00 2 0.7 3.8 0.4 2.3 0.6 3.8 1.1 1.4 0.6 3 0.4 62 10 46 255 16.1 0 16.3 15.7 08/08/2005 22:00:00 2.3 0.6 3.8 0.7 2.6 0.5 4.2 1.5 1.9 0.6 3.4 0.4 60 16 52 255 15.5 0 16 15.5 08/08/2005 22:10:00 2.5 0.6 4.6 1.1 2.8 0.5 4.6 1.5 2 0.5 3.8 1.1 42 9 46 255 15.8 0 16 15.7 08/08/2005 22:20:00 3.2 0.8 4.9 0.4 3.4 0.7 4.9 1.5 2.3 0.9 4.6 0.4 36 13 34 255 15.7 0 16.3 15.7 08/08/2005 22:30:00 3.1 0.7 5.3 1.1 3.2 0.7 5.3 1.9 2.1 0.9 4.6 0.4 47 15 58 255 15.7 0.1 16.6 15.7 08/08/2005 22:40:00 3.6 0.9 5.3 0.4 3.9 0.8 5.7 1.9 2.6 0.8 4.6 0.7 51 13 61 255 16.3 0.1 16.8 16 08/08/2005 22:50:00 3.9 1 6.1 1.1 4.1 0.9 6.1 1.9 2.8 0.9 5.3 0.4 57 16 48 255 16.6 0 17.1 16.6 08/08/2005 23:00:00 3.7 0.8 6.1 1.1 3.8 0.8 6.1 1.5 2.4 0.9 5.3 0.4 56 15 74 255 16.7 0 17.1 16.6 08/08/2005 23:10:00 2.9 0.5 4.6 1.9 3.1 0.5 4.9 1.9 2.2 0.6 3.8 0.7 46 10 41 255 16.2 0.1 16.8 16 08/08/2005 23:20:00 2.4 0.4 3.4 1.5 2.6 0.4 3.8 1.9 1.6 0.6 3 0.4 46 9 35 255 15.5 0.4 16.3 14.9 08/08/2005 23:30:00 2.3 0.6 4.2 0.4 2.5 0.6 4.2 1.1 1 0.5 2.6 0.4 54 11 51 255 14.3 0.3 15.2 13.8 08/08/2005 23:40:00 2.1 0.6 3.4 0.7 2.4 0.5 3.8 1.1 1.2 0.6 2.6 0.4 59 9 62 255 13.6 0.1 14.1 13.3 08/08/2005 23:50:00 1.9 0.6 3.4 0.7 2.1 0.5 3.8 1.5 0.9 0.5 2.3 0.4 47 10 49 255 13.1 0.2 13.5 12.7 08/09/2005 00:00:00 0.8 0.6 3 0.4 1.4 0.4 3 0.4 0.4 0.2 1.9 0.4 44 7 55 255 12.9 0.1 13.3 12.7 08/09/2005 00:10:00 0.8 0.6 2.6 0.4 1.2 0.6 3.4 0.4 0.4 0.2 1.9 0.4 62 8 35 255 12.8 0 13 12.7 08/09/2005 00:20:00 1 0.7 3 0.4 1.5 0.6 3 0.4 0.6 0.5 2.6 0.4 51 7 39 255 12.7 0 13 12.5 08/09/2005 00:30:00 1 0.7 2.6 0.4 1.4 0.6 3 0.4 0.4 0.2 1.5 0.4 59 4 53 255 12.5 0.1 12.7 12.5 08/09/2005 00:40:00 1.4 0.7 3.4 0.4 1.9 0.5 3.4 0.7 0.6 0.4 1.9 0.4 67 6 56 255 12.4 0 12.7 12.2 08/09/2005 00:50:00 0.6 0.4 1.5 0.4 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 79 8 71 255 12.4 0.2 12.7 12.2 08/09/2005 01:00:00 0.7 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0.1 0.7 0.4 77 9 58 255 12.4 0.1 12.7 12.2 08/09/2005 01:10:00 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 68 7 63 255 12.3 0 12.7 12.2 08/09/2005 01:20:00 1.2 0.6 2.3 0.4 1.6 0.5 2.6 0.4 0.4 0.2 1.5 0.4 64 14 59 255 12.1 0 12.7 11.9 08/09/2005 01:30:00 2.1 0.5 3.8 1.1 2.3 0.5 3.8 1.5 1.4 0.4 2.6 0.4 62 10 58 255 12 0 12.5 11.9 08/09/2005 01:40:00 0.9 0.7 2.6 0.4 1.4 0.6 3 0.4 0.5 0.3 1.9 0.4 50 9 57 255 12 0 12.2 11.9 08/09/2005 01:50:00 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 0.4 0.2 1.5 0.4 68 8 84 255 12.3 0 12.2 12.2 08/09/2005 02:00:00 1.2 0.5 2.6 0.4 1.6 0.4 3 0.7 0.4 0.1 1.1 0.4 74 5 86 255 12.1 0 12.2 11.9 08/09/2005 02:10:00 0.7 0.4 1.9 0.4 1.3 0.4 2.6 0.7 0.4 0.1 1.1 0.4 82 8 93 255 12 0 12.2 11.9 08/09/2005 02:20:00 0.9 0.4 1.9 0.4 1.3 0.4 2.3 0.4 0.5 0.2 1.5 0.4 108 7 109 255 12 0 12.2 11.9 08/09/2005 02:30:00 1.5 0.4 2.3 0.4 1.7 0.4 2.6 0.7 0.7 0.3 1.9 0.4 115 8 115 255 11.9 0 12.2 11.7 08/09/2005 02:40:00 1.8 0.5 2.6 0.4 1.9 0.5 2.6 0.7 0.8 0.4 1.9 0.4 115 8 111 255 11.8 0 11.9 11.7 08/09/2005 02:50:00 1.9 0.5 3 0.4 2 0.4 3 0.7 0.8 0.4 2.3 0.4 114 8 111 255 11.9 0 12.2 11.7 08/09/2005 03:00:00 2 0.5 3.4 0.7 2.1 0.5 3.4 0.7 0.9 0.5 2.3 0.4 115 8 114 255 12 0 11.9 11.9 08/09/2005 03:10:00 1.8 0.6 3 0.4 2 0.5 3 0.7 1 0.5 2.3 0.4 119 10 96 255 11.9 0 11.9 11.7 08/09/2005 03:20:00 1.8 0.6 3 0.4 1.9 0.5 3.4 0.7 0.9 0.5 2.3 0.4 112 9 114 255 12.1 0 12.2 11.7 08/09/2005 03:30:00 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.4 0 0.7 0.4 100 3 94 255 11.9 0.1 12.2 11.7 08/09/2005 03:40:00 1.4 0.2 1.9 0.7 1.5 0.2 1.9 0.7 0.4 0 0.7 0.4 97 3 99 255 11.8 0 11.9 11.7 08/09/2005 03:50:00 0.8 0.5 1.9 0.4 1.1 0.4 2.3 0.4 0.4 0.1 1.1 0.4 81 7 67 255 11.9 0 11.9 11.7 08/09/2005 04:00:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 1.1 0.4 2.3 0.4 84 7 72 255 11.8 0 11.9 11.7 08/09/2005 04:10:00 2.6 0.5 3.8 1.5 2.6 0.4 3.8 1.5 1 0.5 2.6 0.4 89 7 90 255 11.7 0 11.7 11.7 08/09/2005 04:20:00 2.9 0.5 3.8 1.5 3 0.4 4.2 1.1 1.4 0.6 3 0.4 99 8 93 255 11.5 0 11.9 11.4 08/09/2005 04:30:00 2.6 0.4 3.8 1.5 2.7 0.3 3.8 1.9 1.4 0.4 2.6 0.4 102 8 98 255 12.1 0 12.7 11.9 08/09/2005 04:40:00 2.4 0.4 3 1.1 2.5 0.4 3.4 1.5 1.1 0.5 2.3 0.4 109 7 104 255 12 0 12.2 11.9 08/09/2005 04:50:00 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.5 1.3 0.5 2.6 0.4 113 8 121 255 11.8 0 11.9 11.7 08/09/2005 05:00:00 2.2 0.5 3.4 1.1 2.2 0.4 3 1.1 0.8 0.5 2.3 0.4 112 9 108 255 11.7 0 11.9 11.7 08/09/2005 05:10:00 2.1 0.4 3.4 1.1 2 0.4 3 1.1 0.7 0.4 1.9 0.4 113 9 108 255 11.7 0 11.9 11.7 08/09/2005 05:20:00 1.8 0.6 3 0.4 1.9 0.6 3 0.4 0.7 0.4 2.3 0.4 116 10 116 255 11.7 0 11.9 11.7 08/09/2005 05:30:00 1 0.5 2.6 0.4 1.1 0.4 2.6 0.4 0.4 0.1 1.5 0.4 94 13 100 255 11.8 0.1 12.5 11.7 08/09/2005 05:40:00 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 83 6 81 255 12.2 0 12.2 11.9 08/09/2005 05:50:00 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.7 0.4 101 10 96 255 12.2 0 12.2 11.9 08/09/2005 06:00:00 1.3 0.3 1.9 0.4 1.4 0.3 1.9 0.7 0.4 0.2 1.1 0.4 100 6 106 255 12.5 0 12.7 12.2 08/09/2005 06:10:00 1.2 0.3 1.9 0.4 1.3 0.4 1.9 0.4 0.4 0.1 1.1 0.4 100 4 102 255 12.7 0 12.7 12.5 08/09/2005 06:20:00 2.2 0.6 3.4 1.1 2.2 0.6 3.4 1.1 1.2 0.6 2.6 0.4 97 6 100 255 13.1 0 13.3 12.7 08/09/2005 06:30:00 2.4 0.5 3.4 1.1 2.4 0.6 3.4 1.1 1.5 0.7 3 0.4 97 7 91 255 13.8 0.2 14.4 13.3 08/09/2005 06:40:00 1.4 0.7 2.6 0.4 1.2 0.7 2.6 0.4 0.7 0.5 2.3 0.4 91 11 82 255 15 0.3 16 14.4 08/09/2005 06:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 90 15 97 255 15.5 0 16 15.5 08/09/2005 07:00:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 40 17 56 255 16.6 0.4 17.1 16 08/09/2005 07:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 24 17 23 255 17.5 0 18.2 17.1 08/09/2005 07:20:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 41 17 52 255 18 0 18.5 17.7 08/09/2005 07:30:00 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 37 19 11 255 18.2 0.1 18.5 17.7 08/09/2005 07:40:00 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 8 6 255 18.5 0.1 19.1 18.2 08/09/2005 07:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 6 10 0 255 19.4 0.1 19.7 18.8 08/09/2005 08:00:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 14 15 26 255 19.5 0.1 20.3 19.4 08/09/2005 08:10:00 1.6 0.5 2.6 0.4 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 18 13 14 255 19.7 0.1 20.3 19.4 08/09/2005 08:20:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.7 1.2 0.5 2.3 0.4 36 14 53 255 19.5 0 20 19.4 08/09/2005 08:30:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1 0.6 2.3 0.4 23 20 25 255 19.5 0.1 20 19.4 08/09/2005 08:40:00 1.7 0.5 3 0.4 1.7 0.5 2.6 0.4 1.4 0.6 3 0.4 31 17 17 255 19.8 0 20.3 19.7 08/09/2005 08:50:00 0.9 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 44 15 63 255 19.8 0 20.5 19.4 08/09/2005 09:00:00 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 43 19 36 255 20.1 0 20.5 20 08/09/2005 09:10:00 0.9 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 346 32 47 255 20.3 0 20.8 20 08/09/2005 09:20:00 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 8 17 25 255 20.8 0.1 21.1 20.5 08/09/2005 09:30:00 0.6 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 7 22 15 255 20.8 0.1 21.1 20.5 08/09/2005 09:40:00 0.5 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.4 1.9 0.4 2 32 31 255 21 0.1 21.4 20.8 08/09/2005 09:50:00 0.8 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 359 18 0 255 21.5 0 22 21.1 08/09/2005 10:00:00 1.4 0.6 2.6 0.4 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 334 30 345 255 21.7 0.1 22.3 21.4 08/09/2005 10:10:00 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 310 18 315 255 21.9 0 22.3 21.7 08/09/2005 10:20:00 1.3 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 314 20 287 255 22.2 0.2 22.9 22 08/09/2005 10:30:00 1.1 0.6 3 0.4 1.2 0.6 3 0.4 1 0.6 3 0.4 334 33 333 255 22.4 0.2 22.9 22 08/09/2005 10:40:00 1.3 0.7 3 0.4 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 343 27 355 255 23.1 0 23.5 22.9 08/09/2005 10:50:00 1.9 0.7 3.8 0.4 1.7 0.6 3.4 0.4 1.7 0.7 3.4 0.4 344 19 337 255 23.2 0 23.5 23.2 08/09/2005 11:00:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.1 0.5 2.6 0.4 326 22 335 255 23.3 0.1 23.8 23.2 08/09/2005 11:10:00 1.1 0.7 3 0.4 1.2 0.7 3 0.4 1 0.7 3 0.4 281 47 337 255 24 0.1 24.4 23.5 08/09/2005 11:20:00 1.5 0.7 3 0.4 1.6 0.7 3.4 0.4 1.5 0.7 3 0.4 289 45 257 255 23.4 0.1 24.4 23.2 08/09/2005 11:30:00 1.3 0.8 3 0.4 1.4 0.7 3 0.4 1.1 0.7 3 0.4 289 41 334 255 23.6 0 23.8 23.5 08/09/2005 11:40:00 0.9 0.6 2.6 0.4 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 288 36 322 255 24 0 24.4 23.8 08/09/2005 11:50:00 1.1 0.7 3 0.4 1.2 0.7 3.4 0.4 0.9 0.6 2.6 0.4 288 72 291 255 24.5 0.1 25 24.4 08/09/2005 12:00:00 1.4 0.8 3.4 0.4 1.5 0.7 3 0.4 1.2 0.7 3 0.4 318 39 283 255 25 0 25.3 25 08/09/2005 12:10:00 1.6 0.7 3 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3.4 0.4 325 38 0 255 24.6 0 25 24.1 08/09/2005 12:20:00 1.7 0.8 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.7 3.4 0.4 329 33 326 255 24.7 0.2 25.3 24.1 08/09/2005 12:30:00 1.9 0.7 3.8 0.4 1.9 0.6 3.8 0.4 1.8 0.6 3.8 0.4 321 22 333 255 25 0 25.3 25 08/09/2005 12:40:00 1.7 1 3.8 0.4 1.8 1 3.8 0.4 1.4 0.9 3.8 0.4 291 39 279 255 25.2 0 25.6 25 08/09/2005 12:50:00 1.6 0.8 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.7 3 0.4 310 32 326 255 25.7 0 26.2 25.3 08/09/2005 13:00:00 1.4 0.7 2.6 0.4 1.6 0.6 3 0.4 1.3 0.8 3 0.4 265 33 246 255 25.7 0 26.2 25.3 08/09/2005 13:10:00 1.4 0.9 3.8 0.4 1.6 0.8 3.8 0.4 1 0.7 2.6 0.4 280 43 295 255 25.7 0 25.9 25.6 08/09/2005 13:20:00 1.7 1 3.8 0.4 1.8 1 3.8 0.4 1.5 1 3.8 0.4 293 38 300 255 25.7 0.1 26.2 25.3 08/09/2005 13:30:00 2.4 0.8 3.8 0.4 2.5 0.7 4.2 0.7 2.1 0.8 3.8 0.4 286 24 290 255 25.8 0 26.2 25.6 08/09/2005 13:40:00 1.7 1 4.2 0.4 2 0.9 4.2 0.4 1.5 0.8 3.4 0.4 283 41 284 255 25.6 0 25.9 25.3 08/09/2005 13:50:00 2.1 0.9 4.9 0.4 2.4 0.7 4.9 0.7 2 0.9 4.2 0.4 311 20 308 255 26.1 0.2 26.5 25.6 08/09/2005 14:00:00 1.2 0.9 4.2 0.4 1.7 0.8 4.2 0.4 1.2 0.8 3.4 0.4 293 47 310 255 26.2 0.2 26.8 25.6 08/09/2005 14:10:00 0.9 0.7 3 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 302 30 292 255 26.7 0 26.8 26.5 08/09/2005 14:20:00 1.8 1.1 3.8 0.4 2.2 0.8 4.2 0.4 1.8 0.7 3.4 0.4 307 22 296 255 26.4 0.1 26.8 26.2 08/09/2005 14:30:00 2.2 1.1 4.6 0.4 2.4 1 4.6 0.4 2.1 1 4.2 0.4 311 39 314 255 26.2 0 26.5 26.2 08/09/2005 14:40:00 1.6 1.3 4.6 0.4 1.9 1.1 4.6 0.4 1.6 1.1 4.9 0.4 307 45 297 255 26.7 0 26.8 26.5 08/09/2005 14:50:00 1.8 1.1 4.2 0.4 2.1 0.9 4.2 0.4 1.7 1 3.8 0.4 318 28 335 255 27.2 0.2 27.7 26.8 08/09/2005 15:00:00 2.1 1 5.3 0.4 2.3 0.9 4.9 0.4 1.5 1 3.8 0.4 321 35 336 255 27.1 0 27.4 26.8 08/09/2005 15:10:00 2.7 1.1 5.3 0.4 2.6 0.9 5.3 0.4 1.9 1.1 4.6 0.4 333 27 332 255 27.3 0 27.7 27.1 08/09/2005 15:20:00 1.6 1.1 4.9 0.4 1.9 1 4.6 0.4 1.5 0.9 4.2 0.4 307 33 327 255 27.5 0.1 27.7 27.4 08/09/2005 15:30:00 1.7 0.8 3.8 0.4 2.1 0.6 3.8 0.7 1.4 0.7 3 0.4 303 32 305 255 27.6 0 27.7 27.4 08/09/2005 15:40:00 1.9 1.1 4.2 0.4 2.3 0.8 4.2 0.4 1.8 1 4.2 0.4 301 24 296 255 27.2 0 27.7 26.8 08/09/2005 15:50:00 3.2 0.7 4.9 0.7 3.3 0.6 4.6 1.5 2.6 0.8 4.2 0.4 290 13 288 255 26.6 0 26.8 26.5 08/09/2005 16:00:00 2.9 1.4 6.1 0.4 3.1 1.3 6.5 1.1 2.5 1.5 6.1 0.4 306 22 295 255 26.5 0 26.5 26.2 08/09/2005 16:10:00 3 0.7 5.3 1.1 3.1 0.7 5.3 1.5 2.7 0.9 5.3 0.4 298 15 294 255 26 0 26.5 25.9 08/09/2005 16:20:00 3.1 0.7 4.9 1.1 3.2 0.6 4.9 1.5 2.5 1 5.3 0.4 307 15 329 255 26.3 0 26.5 26.2 08/09/2005 16:30:00 2.6 0.8 5.3 0.4 2.7 0.8 5.3 1.1 2.4 0.8 4.6 0.4 315 21 295 255 25.9 0.2 26.5 25.6 08/09/2005 16:40:00 2.7 1.1 4.9 0.4 2.8 1 4.9 0.4 2.3 1 4.6 0.4 296 18 267 255 25.3 0 25.6 25.3 08/09/2005 16:50:00 2.6 1.3 5.3 0.4 2.7 1.2 5.3 0.4 2.4 1.1 5.3 0.4 302 17 310 255 25 0 25.3 25 08/09/2005 17:00:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 2.8 1 4.6 0.4 302 16 280 255 25 0 25 25 08/09/2005 17:10:00 3.1 1.3 6.1 0.4 3.2 1.2 6.1 0.7 2.7 1.4 5.7 0.4 294 23 302 255 24.8 0 25 24.7 08/09/2005 17:20:00 2.6 0.8 4.6 0.7 2.7 0.8 4.6 0.7 2.1 0.8 4.6 0.4 286 22 318 255 24.5 0 24.7 24.4 08/09/2005 17:30:00 3 1 5.3 0.4 3.1 1 5.3 0.4 2.7 1 4.6 0.7 286 17 306 255 24.5 0 25.3 24.4 08/09/2005 17:40:00 2.7 0.7 4.6 1.1 2.7 0.6 4.6 1.1 2 0.8 4.6 0.4 297 21 266 255 24.4 0 24.7 24.4 08/09/2005 17:50:00 3 0.9 4.6 0.7 3 0.8 4.6 1.1 2.6 0.9 4.6 0.4 293 18 310 255 24.1 0 24.4 24.1 08/09/2005 18:00:00 3 1 4.9 0.4 3.1 0.8 4.9 1.1 2.3 0.9 5.3 0.4 304 13 291 255 23.9 0 24.1 23.8 08/09/2005 18:10:00 2.5 1.2 4.6 0.4 2.7 1 4.9 0.4 2 1.1 4.2 0.4 277 20 299 255 23.6 0 23.8 23.5 08/09/2005 18:20:00 1.5 1.1 4.6 0.4 1.8 1 4.2 0.4 1.3 0.9 3.8 0.4 291 22 286 255 23.7 0 23.8 23.5 08/09/2005 18:30:00 1.7 1.1 4.6 0.4 2 1 4.6 0.4 1.7 1 4.6 0.4 284 22 284 255 23.3 0 23.5 23.2 08/09/2005 18:40:00 3.2 1 5.3 0.7 3.3 0.9 5.3 1.5 2.4 1 5.3 0.4 271 23 260 255 23.1 0 23.5 22.9 08/09/2005 18:50:00 2 1 4.2 0.4 2.2 0.8 4.2 0.4 1.6 0.8 4.2 0.4 270 17 279 255 23.1 0.1 23.5 22.9 08/09/2005 19:00:00 0.8 0.7 2.6 0.4 1.1 0.7 3 0.4 0.6 0.4 1.9 0.4 270 17 255 255 22.7 0.1 23.5 22.3 08/09/2005 19:10:00 2.3 1 4.2 0.4 2.4 1 4.2 0.4 1.7 0.9 4.2 0.4 262 18 261 255 22.3 0 22.9 22 08/09/2005 19:20:00 1.5 0.6 3 0.4 1.8 0.6 3 0.4 1 0.5 2.3 0.4 267 15 270 255 22.2 0.1 22.9 21.7 08/09/2005 19:30:00 1.1 0.8 3 0.4 1.4 0.7 3 0.4 0.8 0.5 2.6 0.4 240 16 255 255 21.6 0.2 22.3 21.1 08/09/2005 19:40:00 2.6 0.9 4.6 0.4 2.7 0.8 5.3 0.7 1.7 0.8 4.2 0.4 255 17 257 255 21 0 21.4 20.8 08/09/2005 19:50:00 1.8 0.8 3.8 0.4 2.1 0.7 4.2 0.4 1.2 0.6 3 0.4 269 18 245 255 21 0 21.4 20.8 08/09/2005 20:00:00 1.6 0.7 3 0.4 1.9 0.6 3 0.4 1 0.5 2.3 0.4 271 15 271 255 20.5 0 21.1 20 08/09/2005 20:10:00 1.3 0.8 3.4 0.4 1.6 0.6 3.4 0.4 1.1 0.5 2.6 0.4 269 15 280 255 19.7 0.2 20.5 19.4 08/09/2005 20:20:00 1.4 0.9 3 0.4 1.7 0.7 3.4 0.4 1.1 0.7 3 0.4 268 16 256 255 19.1 0 19.4 18.8 08/09/2005 20:30:00 1.7 1 4.2 0.4 2 0.8 4.2 0.4 1 0.6 3.8 0.4 270 21 275 255 19.1 0 19.4 18.8 08/09/2005 20:40:00 1.2 0.9 3.8 0.4 1.6 0.8 3.8 0.4 1 0.6 2.6 0.4 262 20 254 255 19 0 19.1 18.8 08/09/2005 20:50:00 1.8 0.8 3.8 0.4 2.1 0.7 3.8 0.4 1.3 0.7 3.4 0.4 264 15 263 255 18.7 0.1 18.8 18.2 08/09/2005 21:00:00 1.6 0.8 3.4 0.4 2.1 0.6 3.4 0.4 1 0.6 2.6 0.4 266 13 256 255 18.2 0 18.5 17.7 08/09/2005 21:10:00 1.7 0.9 3.4 0.4 2.1 0.7 3.8 0.4 1.3 0.6 3 0.4 264 14 275 255 17.8 0 18 17.4 08/09/2005 21:20:00 0.8 0.6 3.4 0.4 1.5 0.5 3.4 0.4 0.6 0.4 1.9 0.4 269 15 253 255 17.3 0.1 17.7 16.8 08/09/2005 21:30:00 1 0.7 2.6 0.4 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 280 9 266 255 16.6 0.2 17.1 16.3 08/09/2005 21:40:00 1 0.6 2.3 0.4 1.6 0.5 2.6 0.4 0.8 0.5 2.6 0.4 284 10 275 255 15.9 0 16.3 15.7 08/09/2005 21:50:00 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 0.4 0 0.7 0.4 277 11 281 255 15.7 0 16.3 15.5 08/09/2005 22:00:00 1.1 0.8 3.4 0.4 1.5 0.7 3.4 0.4 0.8 0.6 2.3 0.4 285 12 289 255 15.4 0 15.7 15.2 08/09/2005 22:10:00 1.1 0.7 3 0.4 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 262 13 253 255 15.1 0 15.7 15.2 08/09/2005 22:20:00 2.1 0.8 3.8 0.4 2.4 0.7 4.2 0.4 1.3 0.7 3.4 0.4 253 11 249 255 15.2 0.1 15.7 15.2 08/09/2005 22:30:00 1.5 0.7 3 0.4 1.8 0.6 3.4 0.4 1.1 0.6 2.6 0.4 260 10 259 255 15.2 0.1 15.7 15.2 08/09/2005 22:40:00 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.9 0.4 263 13 267 255 14.8 0.2 15.5 14.6 08/09/2005 22:50:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 252 15 231 255 14.3 0.1 15.2 13.8 08/09/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 273 0 255 255 13.9 0 14.6 13.5 08/09/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 255 255 13.6 0.1 13.8 13.3 08/09/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 255 255 13.4 0 13.5 13.3 08/09/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 255 255 13.2 0 13.8 12.7 08/09/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 26 255 255 12.9 0.1 13.3 12.7 08/09/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.9 0 13.3 12.7 08/10/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.7 0 13 12.5 08/10/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.5 0.1 12.7 12.2 08/10/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.5 0.1 12.7 12.2 08/10/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.4 0 12.7 12.2 08/10/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.3 0 12.7 12.2 08/10/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 12.2 0 12.5 11.9 08/10/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 11.9 0.1 12.5 11.9 08/10/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 11.8 0.1 12.5 11.7 08/10/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 185 38 255 255 11.7 0 12.2 11.7 08/10/2005 01:30:00 0.5 0.2 1.5 0.4 0.7 0.5 1.9 0.4 0.8 0.4 1.5 0.4 140 9 125 255 11.6 0 12.2 11.7 08/10/2005 01:40:00 1 0.4 1.9 0.4 1.4 0.3 2.3 0.4 0.7 0.3 1.1 0.4 122 3 120 255 11.5 0 11.9 11.4 08/10/2005 01:50:00 0.4 0.2 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 119 0 119 255 11.3 0.1 11.7 11.1 08/10/2005 02:00:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 0.7 0.4 110 15 86 255 11.3 0 11.7 11.1 08/10/2005 02:10:00 0.9 0.5 1.9 0.4 1.1 0.6 2.3 0.4 0.6 0.3 1.5 0.4 73 10 81 255 11.1 0 11.4 11.1 08/10/2005 02:20:00 0.8 0.4 1.9 0.4 1.1 0.4 2.3 0.4 0.4 0.1 1.1 0.4 57 0 57 255 11.1 0 11.7 11.1 08/10/2005 02:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 57 0 255 255 11.1 0 11.4 11.1 08/10/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 18 255 255 10.9 0 11.1 10.9 08/10/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 125 0 255 255 10.9 0 11.1 10.9 08/10/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 125 0 255 255 10.8 0 11.1 10.6 08/10/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 126 0 255 255 10.5 0 11.1 10.3 08/10/2005 03:20:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 126 0 126 255 10.4 0 10.9 10.3 08/10/2005 03:30:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 126 0 126 255 10.2 0 10.6 10.1 08/10/2005 03:40:00 0.7 0.3 1.1 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 119 4 126 255 10.3 0 10.3 10.3 08/10/2005 03:50:00 0.7 0.4 1.5 0.4 1.1 0.3 1.9 0.4 0.4 0 0.4 0.4 115 1 113 255 10.2 0 10.6 10.3 08/10/2005 04:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.3 1.5 0.4 124 12 113 255 10.1 0 10.6 9.8 08/10/2005 04:10:00 1 0.5 1.9 0.4 1.2 0.5 2.3 0.4 1 0.4 1.5 0.4 145 5 146 255 10 0 10.1 9.8 08/10/2005 04:20:00 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.1 0.6 0.3 1.5 0.4 152 0 153 255 10 0 10.1 9.8 08/10/2005 04:30:00 1.6 0.3 2.3 0.4 1.7 0.3 2.3 0.4 0.8 0.3 1.5 0.4 157 4 153 255 10 0 10.1 9.8 08/10/2005 04:40:00 1.9 0.3 2.3 0.7 2 0.2 2.6 1.1 0.8 0.4 1.9 0.4 155 5 155 255 10 0 10.1 9.8 08/10/2005 04:50:00 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.4 1.9 0.4 142 6 151 255 9.8 0 10.1 9.6 08/10/2005 05:00:00 0.4 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.9 0.5 1.9 0.4 147 4 150 255 9.6 0 9.8 9.6 08/10/2005 05:10:00 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 1.5 0.3 2.3 0.7 139 3 140 255 9.6 0 9.8 9.6 08/10/2005 05:20:00 0.9 0.3 1.5 0.4 1.1 0.4 1.9 0.4 1.3 0.3 1.9 0.4 139 3 136 255 9.8 0 9.8 9.6 08/10/2005 05:30:00 0.9 0.2 1.5 0.4 1.1 0.2 1.5 0.7 0.9 0.4 1.5 0.4 135 1 136 255 9.8 0 10.1 9.6 08/10/2005 05:40:00 0.8 0.3 1.5 0.4 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 132 0 132 255 10 0 10.1 9.8 08/10/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 132 0 133 255 10.2 0 10.3 10.1 08/10/2005 06:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 131 1 133 255 10.5 0.1 10.9 10.3 08/10/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 255 255 10.8 0 10.9 10.6 08/10/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 255 255 11.3 0.2 11.7 10.9 08/10/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 255 255 11.7 0 11.9 11.7 08/10/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 255 255 12.3 0.3 12.7 11.9 08/10/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 20 255 255 13 0.1 13.5 12.7 08/10/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 55 19 255 255 14.4 0.5 15.2 13.5 08/10/2005 07:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 41 3 255 255 15.6 0.3 16.3 15.2 08/10/2005 07:20:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 42 10 35 255 16.4 0.1 16.8 16.3 08/10/2005 07:30:00 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 24 11 7 255 16.6 0 16.8 16.3 08/10/2005 07:40:00 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 13 13 22 255 16.9 0.2 17.4 16.6 08/10/2005 07:50:00 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1 0.4 1.9 0.4 11 13 8 255 17.4 0.1 17.7 17.1 08/10/2005 08:00:00 0.8 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 14 16 8 255 17.5 0 17.7 17.4 08/10/2005 08:10:00 0.5 0.3 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 22 15 9 255 17.8 0.1 18.2 17.4 08/10/2005 08:20:00 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 9 17 343 255 18.5 0.2 19.4 18 08/10/2005 08:30:00 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 8 18 32 255 18.9 0 19.4 18.5 08/10/2005 08:40:00 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0 13 0 255 19 0 19.4 18.8 08/10/2005 08:50:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 355 24 356 255 19.1 0.2 20 18.5 08/10/2005 09:00:00 0.8 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.6 0.4 1.9 0.4 8 18 21 255 19.4 0 20 19.1 08/10/2005 09:10:00 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 0.7 0.4 2.3 0.4 10 45 23 255 19.8 0 20.5 19.4 08/10/2005 09:20:00 0.6 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 327 43 346 255 20.2 0 20.8 20 08/10/2005 09:30:00 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 1 23 329 255 20.5 0 20.8 20.3 08/10/2005 09:40:00 1.5 0.7 3.4 0.4 1.6 0.6 3 0.4 1.4 0.7 3 0.4 332 32 310 255 20.8 0 21.1 20.5 08/10/2005 09:50:00 1.3 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.9 0.5 2.6 0.4 311 22 308 255 20.7 0 21.1 20.5 08/10/2005 10:00:00 2 0.9 4.2 0.4 1.9 0.9 4.6 0.4 1.4 1 4.2 0.4 304 20 300 255 21.3 0.2 21.7 20.8 08/10/2005 10:10:00 2.2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.6 0.9 4.2 0.4 283 39 295 255 21.6 0 21.7 21.4 08/10/2005 10:20:00 2 0.7 3.4 0.4 2 0.7 3.4 0.4 1.6 0.8 3.4 0.4 289 39 308 255 21.6 0 21.7 21.1 08/10/2005 10:30:00 2.5 1 4.6 0.4 2.6 1 4.6 0.4 2.2 1 4.6 0.4 277 35 247 255 21.3 0 21.7 21.1 08/10/2005 10:40:00 2.2 0.9 4.2 0.4 2.2 0.8 4.2 0.4 1.8 1 3.8 0.4 286 39 287 255 21.3 0.3 22.3 20.8 08/10/2005 10:50:00 2.5 1.1 4.9 0.4 2.5 1.1 5.3 0.4 2.2 1.1 4.9 0.4 304 41 301 255 21.7 0 22 21.4 08/10/2005 11:00:00 2.3 1 4.2 0.4 2.4 1 4.6 0.4 1.7 1.1 4.2 0.4 305 29 301 255 21.8 0.2 22.6 21.4 08/10/2005 11:10:00 2.2 0.9 4.2 0.4 2.4 0.7 4.2 0.4 2 0.9 4.6 0.4 309 29 307 255 21.9 0.2 22.6 21.7 08/10/2005 11:20:00 2.3 1 4.9 0.4 2.5 0.9 4.9 0.4 2.3 1 4.9 0.4 293 30 266 255 22.5 0 22.9 22.3 08/10/2005 11:30:00 3.1 1.1 4.9 0.4 3.2 1 5.3 1.1 2.7 1.1 4.9 0.4 303 20 318 255 22.4 0 22.6 22.3 08/10/2005 11:40:00 2.5 1.1 4.6 0.4 2.8 0.9 4.9 0.4 2.4 1 4.6 0.4 298 28 292 255 21.8 0.1 22.3 21.4 08/10/2005 11:50:00 2.8 1.1 4.6 0.4 2.8 1 4.6 0.4 2.4 1.3 5.3 0.4 316 29 329 255 22.1 0.1 22.3 21.7 08/10/2005 12:00:00 2.4 1 4.6 0.4 2.6 0.8 4.9 0.4 2.2 1 4.9 0.4 289 24 299 255 22.2 0 22.6 22 08/10/2005 12:10:00 1.9 1.1 4.6 0.4 2.1 1 4.6 0.4 1.6 1 3.8 0.4 314 41 310 255 22.7 0 22.9 22.3 08/10/2005 12:20:00 2 1 3.8 0.4 2.2 0.9 4.2 0.4 1.7 1 4.2 0.4 306 36 229 255 23.2 0 23.5 22.9 08/10/2005 12:30:00 1.6 1 4.2 0.4 1.8 0.9 4.2 0.4 1.4 1.1 4.2 0.4 281 36 255 255 23.4 0 23.5 23.5 08/10/2005 12:40:00 2.1 1.2 4.9 0.4 2.3 1 4.9 0.4 1.9 1.1 3.8 0.4 294 32 290 255 23.4 0.3 23.8 22.9 08/10/2005 12:50:00 2.6 1 4.6 0.4 2.6 0.9 4.6 0.4 2.1 1.1 4.2 0.4 303 33 328 255 23 0 23.2 22.9 08/10/2005 13:00:00 1.5 0.8 3.4 0.4 1.7 0.7 3.8 0.4 1.3 0.7 3.4 0.4 306 33 329 255 23.7 0.2 24.1 23.2 08/10/2005 13:10:00 1.4 1 4.2 0.4 1.7 1 4.2 0.4 1.3 0.8 3.4 0.4 280 56 273 255 24.4 0.1 24.7 24.1 08/10/2005 13:20:00 1.2 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.1 0.7 3 0.4 252 41 247 255 24.1 0.2 24.7 23.8 08/10/2005 13:30:00 1.5 1 4.6 0.4 1.8 1 4.6 0.4 1.4 0.8 3.4 0.4 265 47 339 255 24.6 0 25 24.4 08/10/2005 13:40:00 1.7 1 4.2 0.4 1.9 1 4.2 0.4 1.5 1 4.2 0.4 312 33 309 255 24.5 0 24.7 24.4 08/10/2005 13:50:00 1.1 0.8 3.4 0.4 1.3 0.8 3 0.4 1 0.7 3 0.4 270 53 278 255 24.6 0.1 25 24.4 08/10/2005 14:00:00 1.8 1 4.9 0.4 1.9 0.8 4.6 0.4 1.5 0.8 3.8 0.4 281 41 252 255 25 0 25.3 25 08/10/2005 14:10:00 1.7 0.9 4.2 0.4 1.9 0.7 3.8 0.4 1.4 0.8 3.4 0.4 300 47 317 255 25.3 0 25.6 25 08/10/2005 14:20:00 1.8 0.7 3.4 0.4 1.9 0.5 3 0.7 1.4 0.8 3.4 0.4 339 27 340 255 25 0 25.3 25 08/10/2005 14:30:00 2.1 0.9 4.6 0.4 2.1 0.7 3.8 0.4 1.8 0.7 3.4 0.4 355 23 302 255 25 0.1 25.3 25 08/10/2005 14:40:00 1.9 0.7 3.8 0.4 1.9 0.5 3.4 0.7 1.3 0.5 2.6 0.4 349 22 332 255 25.2 0 25.6 25 08/10/2005 14:50:00 2.1 1 4.6 0.4 2.1 0.8 4.6 0.4 1.8 1 3.8 0.4 317 20 317 255 25.5 0 25.6 25.3 08/10/2005 15:00:00 1.2 0.7 3 0.4 1.4 0.6 3 0.4 1 0.6 2.6 0.4 333 49 320 255 25.5 0 25.6 25.3 08/10/2005 15:10:00 1.5 0.9 3.4 0.4 1.7 0.8 3.4 0.4 1.2 0.8 3.8 0.4 299 30 310 255 25.4 0.2 25.9 25.3 08/10/2005 15:20:00 2.1 0.7 3.4 0.4 2.1 0.6 3.4 0.4 1.6 0.6 3 0.4 331 30 337 255 25.5 0 25.6 25.3 08/10/2005 15:30:00 2 0.9 3.4 0.4 2.1 0.8 3.8 0.4 1.8 0.9 3.4 0.4 293 23 291 255 25.6 0 25.6 25.6 08/10/2005 15:40:00 2 0.7 3.4 0.4 2 0.6 3.4 0.4 1.5 0.9 3.4 0.4 286 21 282 255 25.8 0 26.2 25.6 08/10/2005 15:50:00 1.4 0.8 3 0.4 1.4 0.6 3 0.4 1.1 0.7 3 0.4 314 43 318 255 25.7 0 25.9 25.6 08/10/2005 16:00:00 1.7 0.9 3.8 0.4 1.8 0.8 3.8 0.4 1 0.7 3 0.4 330 29 313 255 25.8 0.1 26.2 25.6 08/10/2005 16:10:00 1.9 0.8 3.4 0.4 1.9 0.6 3.4 0.4 1.4 0.9 3.8 0.4 331 22 334 255 26 0 26.2 25.9 08/10/2005 16:20:00 1.6 0.7 3 0.4 1.8 0.6 3.4 0.7 1.3 0.8 3 0.4 312 26 300 255 25.6 0.3 25.9 25.3 08/10/2005 16:30:00 1.6 0.7 3.4 0.4 1.7 0.5 3 0.4 1 0.7 3 0.4 325 27 286 255 25 0 25.3 24.7 08/10/2005 16:40:00 1.4 0.8 3 0.4 1.5 0.6 3 0.4 0.9 0.7 3.4 0.4 314 27 327 255 24.6 0 25 24.4 08/10/2005 16:50:00 1.8 0.6 3 0.4 1.9 0.5 3 0.4 1.4 0.7 2.6 0.4 289 15 290 255 24.1 0.2 24.4 23.8 08/10/2005 17:00:00 1.5 1 4.2 0.4 1.6 0.9 3.8 0.4 1.1 0.8 3.4 0.4 312 15 311 255 23.8 0 24.1 23.8 08/10/2005 17:10:00 1.4 0.9 3.8 0.4 1.6 0.8 3.8 0.4 1 0.7 3 0.4 308 29 284 255 23.8 0 23.8 23.5 08/10/2005 17:20:00 2.2 0.7 3.8 0.4 2.3 0.6 3.8 0.4 1.6 0.8 3.4 0.4 280 15 300 255 23.5 0 23.8 23.5 08/10/2005 17:30:00 2.3 0.6 4.2 0.4 2.3 0.5 3.8 0.7 1.7 0.7 3.8 0.4 281 16 267 255 23.4 0 23.8 23.5 08/10/2005 17:40:00 1.6 0.8 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.8 3.4 0.4 299 21 286 255 23.3 0 23.8 23.5 08/10/2005 17:50:00 1.7 0.9 3.4 0.4 1.8 0.8 3.8 0.4 1.2 0.8 3.4 0.4 295 17 290 255 23.1 0.1 23.8 22.9 08/10/2005 18:00:00 2.1 0.8 3.8 0.4 2.2 0.7 3.8 0.7 1.7 0.9 3.8 0.4 298 15 318 255 22.9 0 23.2 22.9 08/10/2005 18:10:00 2.4 1 3.8 0.4 2.4 1 4.2 0.4 1.9 0.9 3.8 0.4 300 17 294 255 22.8 0 22.9 22.6 08/10/2005 18:20:00 2.2 0.7 3.4 0.4 2.3 0.6 3.4 0.7 1.7 0.8 3 0.4 286 12 278 255 22.7 0 22.9 22.6 08/10/2005 18:30:00 2.3 0.5 3.4 1.1 2.3 0.4 3.4 1.5 1.5 0.6 3 0.4 302 14 270 255 22.5 0.1 23.2 22 08/10/2005 18:40:00 2.3 0.6 3.4 0.4 2.4 0.5 3.4 1.1 1.8 0.7 3.4 0.4 292 13 282 255 22 0.1 22.6 21.7 08/10/2005 18:50:00 1.5 0.6 3 0.4 1.6 0.5 3 0.7 0.9 0.6 2.6 0.4 292 13 258 255 21.8 0.1 22.3 21.7 08/10/2005 19:00:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1 0.5 2.3 0.4 295 10 315 255 21.5 0 22.3 21.1 08/10/2005 19:10:00 1.7 0.6 3 0.4 1.8 0.5 3 0.4 1.4 0.5 2.6 0.4 286 11 290 255 21.1 0 21.7 21.1 08/10/2005 19:20:00 1.5 0.5 2.6 0.4 1.7 0.4 2.6 0.7 1.2 0.5 2.3 0.4 290 7 295 255 20.8 0.1 21.4 20.5 08/10/2005 19:30:00 2.2 0.3 3 1.1 2.2 0.3 3 1.5 1.7 0.4 2.6 0.4 293 6 287 255 20.3 0 20.5 20 08/10/2005 19:40:00 1.6 0.4 3 0.4 1.7 0.4 2.6 0.7 1 0.5 2.3 0.4 296 6 288 255 19.9 0 20.5 19.7 08/10/2005 19:50:00 1.6 0.4 2.6 0.7 1.7 0.3 2.3 0.7 1 0.4 1.9 0.4 296 9 306 255 19.5 0 20 19.4 08/10/2005 20:00:00 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 279 10 284 255 19.4 0 19.4 19.4 08/10/2005 20:10:00 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 258 5 267 255 19.3 0 19.4 19.1 08/10/2005 20:20:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 276 38 2 255 19 0 19.4 18.8 08/10/2005 20:30:00 1.6 0.4 2.3 0.4 1.7 0.3 2.3 0.4 0.5 0.3 1.5 0.4 11 6 2 255 18.6 0.1 18.8 18.2 08/10/2005 20:40:00 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 0.5 0.3 1.9 0.4 18 9 27 255 18.2 0 18.5 18 08/10/2005 20:50:00 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 18 4 17 255 17.8 0 18.2 17.4 08/10/2005 21:00:00 0.6 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 19 2 18 255 17.4 0.1 17.7 16.8 08/10/2005 21:10:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 21 0 21 255 16.9 0 17.1 16.8 08/10/2005 21:20:00 1.2 0.3 1.9 0.4 1.4 0.3 1.9 0.7 0.4 0.1 1.1 0.4 11 5 11 255 16.5 0.1 16.8 16.3 08/10/2005 21:30:00 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 16 3 11 255 16 0 16.6 15.7 08/10/2005 21:40:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 18 10 19 255 15.7 0 16.3 15.5 08/10/2005 21:50:00 1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.5 0.3 1.5 0.4 56 2 56 255 15.3 0.1 15.7 15.2 08/10/2005 22:00:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 62 6 73 255 15 0 15.5 14.9 08/10/2005 22:10:00 0.6 0.4 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 77 7 85 255 14.8 0.1 15.2 14.6 08/10/2005 22:20:00 0.7 0.5 1.9 0.4 0.8 0.6 1.9 0.4 0.6 0.4 1.5 0.4 68 7 69 255 14.6 0 14.9 14.6 08/10/2005 22:30:00 1.2 0.3 1.9 0.4 1.3 0.2 1.9 0.7 0.4 0.2 1.1 0.4 80 0 80 255 14.3 0.2 14.9 13.8 08/10/2005 22:40:00 1.3 0.2 1.9 0.4 1.3 0.2 1.9 0.7 0.4 0 0.4 0.4 98 12 80 255 14.1 0.2 14.6 13.8 08/10/2005 22:50:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.5 0.2 1.1 0.4 94 9 87 255 13.9 0 14.4 13.5 08/10/2005 23:00:00 1.4 0.4 2.3 0.7 1.5 0.4 2.3 0.7 0.6 0.3 1.5 0.4 76 7 73 255 13.5 0 13.8 13.3 08/10/2005 23:10:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.5 0.4 79 8 73 255 13.3 0 13.5 13 08/10/2005 23:20:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 95 8 102 255 13.1 0.1 13.3 13 08/10/2005 23:30:00 1.3 0.4 1.9 0.4 1.3 0.4 1.9 0.4 0.4 0.1 1.1 0.4 101 1 101 255 12.9 0.1 13.5 12.7 08/10/2005 23:40:00 1.3 0.2 2.3 0.7 1.2 0.2 1.9 0.7 0.4 0 0.4 0.4 101 0 101 255 12.8 0 13.3 12.7 08/10/2005 23:50:00 1.5 0.2 2.3 1.1 1.6 0.3 2.3 1.1 0.4 0.2 1.1 0.4 87 9 80 255 12.7 0 13 12.5 08/11/2005 00:00:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.4 0 0.7 0.4 82 0 83 255 12.5 0.1 13 12.2 08/11/2005 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 83 0 83 255 12.3 0 12.7 12.2 08/11/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 0 255 255 12.3 0 12.5 12.2 08/11/2005 00:30:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 83 0 83 255 12.1 0 12.5 11.9 08/11/2005 00:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 83 0 83 255 12 0 12.5 11.9 08/11/2005 00:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 83 0 83 255 11.9 0.1 12.5 11.7 08/11/2005 01:00:00 0.8 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 92 5 83 255 11.9 0.1 12.5 11.7 08/11/2005 01:10:00 0.9 0.2 1.5 0.4 0.7 0.3 1.1 0.4 0.4 0.1 1.1 0.4 95 0 95 255 11.8 0 12.5 11.7 08/11/2005 01:20:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 95 0 95 255 11.7 0 12.2 11.7 08/11/2005 01:30:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 95 0 95 255 11.7 0 11.7 11.7 08/11/2005 01:40:00 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 95 0 95 255 11.5 0 11.7 11.4 08/11/2005 01:50:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 95 0 95 255 11.5 0 11.7 11.4 08/11/2005 02:00:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 117 12 125 255 11.3 0 11.7 11.1 08/11/2005 02:10:00 1.7 0.3 2.6 0.7 1.7 0.3 2.3 0.7 1.1 0.4 1.9 0.4 131 7 136 255 11.1 0 11.4 10.9 08/11/2005 02:20:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 0.9 0.4 1.9 0.4 126 8 132 255 11 0 11.4 10.9 08/11/2005 02:30:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1.2 0.4 2.3 0.4 130 6 121 255 10.9 0 11.4 10.9 08/11/2005 02:40:00 1.8 0.4 2.6 0.7 1.8 0.3 2.6 1.1 0.7 0.4 1.5 0.4 120 5 127 255 11 0 11.4 10.9 08/11/2005 02:50:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.4 0.1 1.1 0.4 115 4 115 255 11 0 11.1 10.9 08/11/2005 03:00:00 1.1 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 104 7 111 255 10.9 0 11.4 10.9 08/11/2005 03:10:00 1.1 0.2 1.9 0.7 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 101 0 102 255 10.8 0 10.9 10.6 08/11/2005 03:20:00 1.7 0.3 2.3 0.7 1.4 0.3 2.3 0.4 0.4 0.1 1.1 0.4 108 4 104 255 10.7 0 11.1 10.6 08/11/2005 03:30:00 1.1 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 111 1 112 255 10.6 0 10.9 10.6 08/11/2005 03:40:00 1.6 0.4 3 0.4 1.3 0.5 2.6 0.4 0.6 0.4 1.9 0.4 117 6 119 255 10.6 0 10.6 10.6 08/11/2005 03:50:00 1.5 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 122 9 116 255 10.4 0 10.6 10.3 08/11/2005 04:00:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.9 0.4 1.9 0.4 138 8 142 255 10.3 0 10.6 10.3 08/11/2005 04:10:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.4 0.2 1.5 0.4 147 8 148 255 10.5 0 10.6 10.3 08/11/2005 04:20:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 119 10 134 255 10.4 0.1 10.6 10.3 08/11/2005 04:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 116 5 124 255 10.3 0 10.6 10.3 08/11/2005 04:40:00 1.2 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 133 8 126 255 10.5 0 10.6 10.6 08/11/2005 04:50:00 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 141 6 144 255 10.6 0 10.6 10.6 08/11/2005 05:00:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 133 5 134 255 10.5 0 10.6 10.3 08/11/2005 05:10:00 2 0.2 2.6 1.1 1.7 0.3 2.6 0.7 0.4 0.2 1.1 0.4 115 5 117 255 10.4 0 10.6 10.3 08/11/2005 05:20:00 2 0.3 2.6 1.1 1.9 0.3 2.6 0.7 0.7 0.4 1.9 0.4 113 7 125 255 10.3 0 10.6 10.3 08/11/2005 05:30:00 2.1 0.3 3 1.1 1.9 0.3 2.6 0.7 0.8 0.4 1.5 0.4 108 7 102 255 10.5 0 10.6 10.3 08/11/2005 05:40:00 2.1 0.3 2.6 1.1 1.8 0.3 2.6 0.4 0.7 0.4 1.5 0.4 109 8 102 255 10.7 0 10.9 10.6 08/11/2005 05:50:00 1.3 0.7 3 0.4 1 0.7 2.6 0.4 0.5 0.3 1.9 0.4 121 10 108 255 10.7 0 10.9 10.6 08/11/2005 06:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 124 1 124 255 11 0 11.1 10.6 08/11/2005 06:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 118 6 123 255 11.2 0 11.4 11.1 08/11/2005 06:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 109 255 11.7 0.1 11.9 11.4 08/11/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 12.1 0 12.5 11.9 08/11/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 12.6 0.3 13.3 12.2 08/11/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 13.3 0.2 13.8 12.7 08/11/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 14.6 0.5 15.7 13.5 08/11/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 16.1 0.4 16.8 15.2 08/11/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 15 255 255 16.6 0 17.1 16.6 08/11/2005 07:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 35 18 11 255 17.1 0.3 17.4 16.6 08/11/2005 07:40:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 356 11 8 255 17.4 0.1 18 17.1 08/11/2005 07:50:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 355 7 349 255 17.6 0 18 17.4 08/11/2005 08:00:00 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 357 7 358 255 17.8 0 18 17.7 08/11/2005 08:10:00 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 17 13 17 255 18.1 0.1 18.8 17.7 08/11/2005 08:20:00 0.9 0.5 2.3 0.4 0.9 0.4 2.3 0.4 0.6 0.3 1.5 0.4 348 22 21 255 18.3 0.1 19.1 18 08/11/2005 08:30:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 4 9 32 255 18.8 0.1 19.4 18.5 08/11/2005 08:40:00 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 16 26 339 255 19 0 19.4 18.8 08/11/2005 08:50:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0 16 356 255 19.1 0.2 19.7 18.8 08/11/2005 09:00:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 32 26 46 255 19.4 0 20 19.1 08/11/2005 09:10:00 0.8 0.5 2.3 0.4 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 25 33 10 255 19.9 0 20.3 19.4 08/11/2005 09:20:00 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.6 0.4 12 28 44 255 20.1 0.1 20.5 19.7 08/11/2005 09:30:00 0.8 0.5 2.6 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 67 36 97 255 20.5 0 21.1 20.3 08/11/2005 09:40:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 62 29 20 255 20.8 0 21.1 20.5 08/11/2005 09:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 31 18 40 255 21 0 21.1 20.8 08/11/2005 10:00:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.5 2.3 0.4 293 64 358 255 21 0.3 21.4 20.5 08/11/2005 10:10:00 1.9 0.7 3 0.4 1.9 0.7 3 0.4 1.5 0.6 3 0.4 34 45 22 255 21.4 0.3 22 20.8 08/11/2005 10:20:00 1.5 0.6 2.6 0.4 1.6 0.4 2.6 0.4 1.3 0.4 2.3 0.4 36 21 20 255 21.7 0 22 21.4 08/11/2005 10:30:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 324 53 7 255 22.2 0.1 22.9 22 08/11/2005 10:40:00 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.6 2.3 0.4 10 35 7 255 22.3 0 22.9 22.3 08/11/2005 10:50:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 64 76 17 255 22.1 0 22.6 22 08/11/2005 11:00:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 11 29 34 255 22.8 0.1 23.2 22.3 08/11/2005 11:10:00 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 67 22 58 255 22.6 0.1 22.9 22.3 08/11/2005 11:20:00 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 14 61 19 255 23.2 0.2 23.8 22.9 08/11/2005 11:30:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.2 0.8 3 0.4 355 39 332 255 23.8 0 24.1 23.8 08/11/2005 11:40:00 1 0.7 3 0.4 1 0.7 3 0.4 0.8 0.6 2.3 0.4 52 98 3 255 23.7 0 23.8 23.5 08/11/2005 11:50:00 1.5 0.7 2.6 0.4 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 355 24 347 255 23.7 0.1 24.1 23.5 08/11/2005 12:00:00 1.2 0.6 2.6 0.4 1.4 0.5 2.3 0.4 1.2 0.5 2.6 0.4 49 23 30 255 23.8 0 24.1 23.5 08/11/2005 12:10:00 1.6 0.8 3.8 0.4 1.7 0.7 3.4 0.4 1.3 0.6 3 0.4 21 38 356 255 23.8 0.2 24.4 23.5 08/11/2005 12:20:00 0.8 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.6 3.4 0.4 48 22 31 255 24.3 0 24.4 24.1 08/11/2005 12:30:00 1.8 0.8 3.4 0.4 1.8 0.6 3.8 0.4 1.4 0.7 3 0.4 346 20 349 255 24.7 0 25 24.4 08/11/2005 12:40:00 1.2 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.2 0.6 2.6 0.4 30 24 14 255 25 0 25.3 25 08/11/2005 12:50:00 0.6 0.5 2.3 0.4 0.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 40 41 31 255 25 0.1 25.3 25 08/11/2005 13:00:00 1.2 0.7 3 0.4 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 303 45 298 255 25.3 0 25.6 25.3 08/11/2005 13:10:00 1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 3 32 325 255 25.6 0 25.9 25.3 08/11/2005 13:20:00 2 0.6 3.4 0.4 2 0.5 3.4 0.7 1.6 0.6 2.6 0.4 14 26 354 255 25.7 0 25.9 25.6 08/11/2005 13:30:00 1.8 0.6 3.8 0.4 1.8 0.6 3.8 0.4 1.5 0.7 3.4 0.4 2 32 20 255 26 0.2 26.5 25.6 08/11/2005 13:40:00 1.8 0.9 3.8 0.4 1.9 0.6 3.4 0.4 1.5 0.7 3.4 0.4 345 28 321 255 26.2 0 26.5 26.2 08/11/2005 13:50:00 1.7 0.8 3.8 0.4 1.9 0.7 3.8 0.4 1.4 0.7 3 0.4 8 21 32 255 26.3 0 26.5 26.2 08/11/2005 14:00:00 1.8 0.8 3.4 0.4 1.8 0.7 3.4 0.4 1.4 0.6 3 0.4 349 29 331 255 26.6 0 26.8 26.2 08/11/2005 14:10:00 1.3 0.8 3.4 0.4 1.5 0.7 3 0.4 1.1 0.7 3.4 0.4 24 79 348 255 26.6 0 26.8 26.5 08/11/2005 14:20:00 1.9 1.1 4.6 0.4 2.1 0.9 4.6 0.4 1.8 1 4.2 0.4 359 23 358 255 26.6 0 26.8 26.5 08/11/2005 14:30:00 2.1 1 4.2 0.4 2.1 0.7 3.8 0.4 1.7 0.8 3.8 0.4 339 29 314 255 27.2 0.1 27.4 26.8 08/11/2005 14:40:00 2 0.9 4.2 0.4 1.9 0.8 3.8 0.4 1.5 0.9 3.8 0.4 334 29 14 255 26.9 0 27.1 26.8 08/11/2005 14:50:00 1.9 0.9 3.8 0.4 2 0.8 4.2 0.7 1.6 0.9 3.8 0.4 334 26 300 255 26.7 0 27.1 26.5 08/11/2005 15:00:00 2.2 0.7 4.2 0.7 2.2 0.6 3.8 0.7 1.3 0.8 4.2 0.4 339 24 325 255 27.4 0.2 28 26.5 08/11/2005 15:10:00 1.3 0.9 3.4 0.4 1.5 0.8 3.4 0.4 0.9 0.7 3 0.4 321 58 253 255 27.6 0 28 27.4 08/11/2005 15:20:00 1.8 0.7 3.4 0.4 1.8 0.6 3 0.4 1.6 0.6 3 0.4 319 69 350 255 27.7 0.1 28 27.4 08/11/2005 15:30:00 1.5 0.7 3.4 0.4 1.7 0.6 3 0.4 1.1 0.7 2.6 0.4 339 36 300 255 27.8 0 28 27.4 08/11/2005 15:40:00 1.2 0.7 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.6 2.6 0.4 319 61 272 255 27.8 0.2 28.3 27.4 08/11/2005 15:50:00 1 0.6 2.6 0.4 1.3 0.5 3 0.4 0.9 0.6 2.6 0.4 317 47 355 255 28.2 0 28.3 28 08/11/2005 16:00:00 1.7 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.3 0.7 2.6 0.4 5 19 14 255 28.6 0 29 28.3 08/11/2005 16:10:00 1.6 0.7 3.4 0.4 1.7 0.6 3.4 0.4 1.3 0.7 2.6 0.4 14 19 341 255 28 0.1 28.6 27.7 08/11/2005 16:20:00 1.6 0.6 3 0.4 1.7 0.5 2.6 0.4 1.1 0.6 2.6 0.4 4 24 352 255 27.4 0.1 27.7 27.1 08/11/2005 16:30:00 1 0.7 3 0.4 1.3 0.7 3.4 0.4 0.8 0.6 3 0.4 321 30 323 255 27 0.1 27.4 26.5 08/11/2005 16:40:00 1.2 0.7 3 0.4 1.4 0.5 2.6 0.4 1 0.6 2.6 0.4 332 30 299 255 26.3 0.1 26.5 26.2 08/11/2005 16:50:00 0.8 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.5 2.3 0.4 322 45 331 255 25.9 0 26.2 25.9 08/11/2005 17:00:00 1.7 0.5 2.6 0.4 1.7 0.5 3 0.4 1.2 0.6 2.6 0.4 346 14 331 255 25.6 0 25.9 25.6 08/11/2005 17:10:00 1.2 0.8 3 0.4 1.3 0.7 2.6 0.4 1 0.7 3 0.4 328 14 340 255 25.3 0 25.6 25.3 08/11/2005 17:20:00 1.4 0.6 3 0.4 1.5 0.4 2.6 0.4 1 0.6 2.6 0.4 323 27 325 255 25 0 25.3 25 08/11/2005 17:30:00 0.7 0.4 2.3 0.4 1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 324 18 304 255 24.7 0 25 24.7 08/11/2005 17:40:00 0.7 0.5 1.9 0.4 1.1 0.5 2.3 0.4 0.6 0.3 1.9 0.4 334 17 342 255 24.6 0 25 24.4 08/11/2005 17:50:00 0.8 0.5 2.6 0.4 1.2 0.4 2.6 0.4 0.9 0.4 2.3 0.4 339 17 324 255 24.7 0 25 24.4 08/11/2005 18:00:00 0.6 0.4 1.9 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 337 17 1 255 24.2 0.2 25 24.1 08/11/2005 18:10:00 0.6 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 332 13 319 255 23.8 0 24.1 23.8 08/11/2005 18:20:00 1.6 0.5 2.6 0.4 1.7 0.4 2.6 0.7 1.2 0.6 2.6 0.4 349 10 336 255 23.5 0.1 24.1 23.5 08/11/2005 18:30:00 2 0.6 3 0.4 2.1 0.5 3.4 0.7 1.4 0.6 2.6 0.4 350 15 340 255 23.2 0 23.5 23.2 08/11/2005 18:40:00 1.6 0.6 3 0.4 1.7 0.6 3 0.4 0.9 0.6 2.6 0.4 347 11 355 255 22.9 0.1 23.2 22.9 08/11/2005 18:50:00 1.8 0.7 3 0.4 1.9 0.6 3 0.7 0.9 0.6 2.3 0.4 4 23 16 255 22.7 0 23.2 22.6 08/11/2005 19:00:00 2.4 0.5 4.2 1.1 2.3 0.5 4.2 1.1 1.4 0.6 3 0.4 354 11 0 255 22.4 0 22.9 22.3 08/11/2005 19:10:00 2.5 0.5 3.4 1.1 2.6 0.5 3.8 1.1 1.4 0.7 3 0.4 10 11 358 255 22.2 0 22.9 22 08/11/2005 19:20:00 2.1 0.7 3.8 0.4 2.3 0.6 3.8 0.7 1.2 0.7 3 0.4 15 12 19 255 21.8 0.1 22.6 21.7 08/11/2005 19:30:00 2.3 0.7 3.8 0.4 2.5 0.6 3.8 1.1 1.8 0.7 3.4 0.4 37 15 41 255 21.9 0.1 22.3 21.7 08/11/2005 19:40:00 2.1 0.5 3 0.7 2.2 0.4 3 1.1 1.5 0.6 2.6 0.4 57 12 69 255 21.9 0 22.3 21.7 08/11/2005 19:50:00 1.9 0.5 3 0.4 2 0.4 3 1.1 1.1 0.6 2.6 0.4 54 12 53 255 21.7 0.1 22.3 21.7 08/11/2005 20:00:00 1.6 0.6 3.4 0.4 1.9 0.5 3.4 0.7 1.2 0.5 2.6 0.4 47 10 39 255 21.3 0.1 22.3 21.1 08/11/2005 20:10:00 1.5 0.7 3 0.4 1.8 0.5 3 0.4 1 0.5 2.6 0.4 47 14 37 255 20.5 0.3 21.1 20 08/11/2005 20:20:00 2.2 0.6 3.8 0.7 2.3 0.5 3.8 1.1 1.4 0.7 3 0.4 53 11 40 255 19.7 0 20 19.7 08/11/2005 20:30:00 1.9 0.8 3.8 0.4 2.1 0.7 3.8 0.4 1.2 0.7 3 0.4 51 13 45 255 19.7 0 20 19.4 08/11/2005 20:40:00 1.5 0.6 3 0.4 1.8 0.4 3 0.7 1 0.5 2.6 0.4 49 13 42 255 19 0 19.4 18.5 08/11/2005 20:50:00 2.1 0.6 3.4 0.4 2.2 0.5 3.8 1.1 1.3 0.6 2.6 0.4 53 12 34 255 18.6 0 18.8 18.5 08/11/2005 21:00:00 1.9 0.5 3.4 0.4 2 0.4 3.8 1.1 1.2 0.5 2.6 0.4 57 10 53 255 18.2 0 18.5 18 08/11/2005 21:10:00 2.2 0.4 3 1.1 2.3 0.4 3.4 1.5 1.4 0.5 2.3 0.4 58 10 46 255 18.2 0 18.2 18 08/11/2005 21:20:00 2.3 0.5 3.4 0.7 2.4 0.5 3.8 1.5 1.7 0.6 3 0.4 61 11 58 255 17.7 0.1 18 17.4 08/11/2005 21:30:00 2.4 0.7 4.2 0.4 2.5 0.6 4.2 1.1 1.4 0.6 3 0.4 64 11 55 255 17.5 0 17.7 17.4 08/11/2005 21:40:00 2.6 0.8 4.9 0.7 2.7 0.7 4.6 1.1 2 0.8 4.2 0.4 65 11 55 255 17.3 0 17.4 16.8 08/11/2005 21:50:00 2.5 0.6 4.6 0.4 2.7 0.6 4.2 1.1 1.7 0.7 3.8 0.4 58 16 65 255 17.1 0 17.4 16.8 08/11/2005 22:00:00 2 0.9 4.6 0.4 2.3 0.7 4.2 0.4 1.1 0.7 3 0.4 59 19 49 255 17.3 0 17.7 17.1 08/11/2005 22:10:00 2.8 0.6 4.9 1.5 2.9 0.6 4.6 1.5 1.8 0.6 3.8 0.4 67 10 66 255 16.8 0 17.4 16.6 08/11/2005 22:20:00 2.8 0.6 4.6 1.5 2.9 0.6 4.6 1.9 1.9 0.6 3.8 0.7 70 9 77 255 16.2 0.1 16.8 16 08/11/2005 22:30:00 3.2 0.8 5.7 0.7 3.4 0.7 6.5 1.5 2.4 0.6 4.6 0.7 65 13 52 255 16.3 0.2 16.8 16 08/11/2005 22:40:00 2.9 0.8 4.6 0.4 3.2 0.6 4.6 1.5 2.2 0.7 3.8 0.4 47 13 43 255 16.8 0 17.1 16.8 08/11/2005 22:50:00 2.9 0.7 4.9 1.1 3.2 0.6 5.3 1.9 2.1 0.6 3.8 0.7 51 11 46 255 17 0 17.1 16.8 08/11/2005 23:00:00 2.6 0.6 3.8 1.1 2.9 0.5 3.8 1.5 1.8 0.5 3 0.7 71 14 86 255 16.3 0.5 17.1 15.5 08/11/2005 23:10:00 3 0.3 3.8 1.9 3.2 0.3 3.8 2.3 2 0.4 3 0.7 90 4 86 255 15.2 0.2 15.7 14.9 08/11/2005 23:20:00 2.8 0.5 4.6 1.5 3.1 0.4 4.6 2.3 1.9 0.4 3 0.7 89 8 73 255 14.8 0 15.5 14.6 08/11/2005 23:30:00 2.8 0.7 4.6 1.1 3 0.6 4.6 1.9 1.9 0.6 3.4 0.4 66 13 77 255 14.8 0 15.2 14.6 08/11/2005 23:40:00 2.8 0.6 4.6 1.5 3 0.6 4.6 1.9 1.9 0.5 3.4 0.4 72 9 58 255 14.6 0 15.2 14.6 08/11/2005 23:50:00 2.6 0.7 4.6 1.1 2.8 0.7 4.6 1.5 1.8 0.7 3.8 0.4 80 15 66 255 14.6 0.1 15.2 14.6 08/12/2005 00:00:00 2.3 0.6 3.8 0.4 2.4 0.6 3.8 0.7 1.2 0.6 2.6 0.4 102 14 66 255 14.6 0 15.2 14.6 08/12/2005 00:10:00 2.8 0.6 4.9 0.7 3.1 0.6 4.9 1.9 1.8 0.6 3.4 0.4 93 8 90 255 14.4 0 14.9 14.4 08/12/2005 00:20:00 2.6 0.5 3.8 1.1 2.9 0.4 3.8 1.9 1.6 0.5 2.6 0.4 92 6 95 255 14.4 0.1 14.9 14.1 08/12/2005 00:30:00 2.5 0.7 4.9 1.1 2.9 0.6 4.6 1.5 1.8 0.8 3.4 0.4 74 7 76 255 14.5 0.2 15.2 14.4 08/12/2005 00:40:00 2.9 0.4 3.8 1.5 3.2 0.4 4.2 2.3 2.2 0.4 3.8 1.1 71 7 69 255 15 0 15.5 14.6 08/12/2005 00:50:00 2.3 0.8 4.2 0.7 2.7 0.7 4.6 1.1 1.5 0.6 3 0.4 73 11 81 255 14.9 0.1 15.5 14.9 08/12/2005 01:00:00 1.8 0.7 4.2 0.4 2.3 0.6 4.2 1.1 1.4 0.6 3.8 0.4 67 8 56 255 15 0 15.5 14.9 08/12/2005 01:10:00 1.3 0.5 2.6 0.4 1.9 0.4 2.6 1.1 0.9 0.4 1.9 0.4 72 8 74 255 14.6 0.2 15.2 14.4 08/12/2005 01:20:00 1.7 0.5 3.4 0.7 2.1 0.4 3 1.1 1.2 0.4 2.3 0.4 64 9 37 255 14.5 0 14.9 14.4 08/12/2005 01:30:00 1.8 0.5 3.4 0.7 2.2 0.5 3.4 1.5 1.5 0.4 2.6 0.4 55 7 49 255 14.6 0.1 15.2 14.6 08/12/2005 01:40:00 1.8 0.6 3.8 0.4 2.2 0.5 4.2 1.1 1.3 0.4 3 0.4 59 8 34 255 14.3 0.2 14.9 14.1 08/12/2005 01:50:00 1.2 0.8 3.8 0.4 1.7 0.6 3.8 0.4 1 0.5 3 0.4 48 6 45 255 13.9 0 14.6 13.8 08/12/2005 02:00:00 0.9 0.5 2.3 0.4 1.4 0.3 2.3 0.7 0.4 0.1 1.1 0.4 69 7 91 255 13.8 0 14.4 13.5 08/12/2005 02:10:00 1.9 0.4 2.6 1.1 2.1 0.3 3 1.5 1 0.4 1.5 0.4 84 6 88 255 13.6 0.1 14.1 13.3 08/12/2005 02:20:00 1.7 0.5 3 0.4 1.8 0.4 2.6 0.7 0.7 0.4 2.3 0.4 64 15 84 255 13.4 0 13.8 13.3 08/12/2005 02:30:00 1.4 0.4 2.6 0.4 1.5 0.4 2.3 0.7 0.4 0.1 1.1 0.4 60 6 55 255 13.4 0 13.8 13.3 08/12/2005 02:40:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 88 22 116 255 13.4 0 13.8 13.3 08/12/2005 02:50:00 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 121 6 123 255 13.4 0 13.8 13.3 08/12/2005 03:00:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.8 0.4 2.3 0.4 117 8 114 255 13.3 0 13.8 13.3 08/12/2005 03:10:00 2.2 0.6 3.4 0.7 2.1 0.5 3 0.7 1 0.6 2.6 0.4 108 5 95 255 13.3 0 13.8 13 08/12/2005 03:20:00 2.9 0.5 3.8 1.9 2.8 0.4 3.8 1.5 1.8 0.5 3 0.4 111 9 100 255 13.4 0 13.8 13.3 08/12/2005 03:30:00 2.6 0.6 4.6 0.7 2.5 0.7 4.2 0.4 1.4 0.6 3 0.4 113 12 108 255 13.3 0 13.8 13 08/12/2005 03:40:00 3.3 0.6 4.6 1.5 3.1 0.5 4.6 1.5 2.1 0.5 3.4 0.7 113 11 111 255 13.7 0 14.1 13.5 08/12/2005 03:50:00 2.1 0.7 3.8 0.4 2 0.7 3.8 0.4 0.9 0.6 3.4 0.4 98 20 119 255 13.9 0 14.4 13.5 08/12/2005 04:00:00 2.4 0.4 3.4 1.1 2.2 0.5 3 0.4 0.9 0.5 1.9 0.4 94 11 99 255 13.5 0 13.5 13.3 08/12/2005 04:10:00 2.1 0.5 3 0.7 1.7 0.7 3 0.4 0.9 0.6 2.3 0.4 106 4 102 255 13.3 0 13.3 13 08/12/2005 04:20:00 1.3 0.3 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 120 8 128 255 13.3 0 13.5 13 08/12/2005 04:30:00 2 0.5 3 1.1 1.7 0.6 3 0.4 1.2 0.5 2.3 0.4 122 8 116 255 13.3 0 13.3 13 08/12/2005 04:40:00 1.6 0.6 3 0.4 1.2 0.6 3 0.4 0.6 0.4 1.9 0.4 109 10 115 255 12.9 0.1 13.3 12.7 08/12/2005 04:50:00 1.9 0.8 3.4 0.4 1.7 0.9 3.8 0.4 0.9 0.6 2.3 0.4 122 11 124 255 12.8 0 13 12.7 08/12/2005 05:00:00 2.3 0.5 3.8 1.1 2.1 0.6 3.8 0.7 1.5 0.6 3 0.4 131 11 133 255 12.7 0 12.7 12.5 08/12/2005 05:10:00 1.9 0.5 3.4 1.1 1.7 0.6 3.4 0.4 1.1 0.7 3 0.4 119 12 134 255 12.7 0 12.7 12.5 08/12/2005 05:20:00 1.8 0.3 2.6 1.1 1.5 0.3 2.3 0.7 0.5 0.3 1.5 0.4 94 4 93 255 12.8 0 13 12.7 08/12/2005 05:30:00 2.2 0.6 3.8 0.4 1.9 0.7 3.8 0.4 0.8 0.5 2.3 0.4 95 9 105 255 12.9 0 13 12.7 08/12/2005 05:40:00 3.2 0.5 4.6 1.5 3 0.5 4.6 1.5 1.9 0.6 3.8 0.4 113 13 107 255 13.1 0 13.3 12.7 08/12/2005 05:50:00 3 0.6 4.6 1.1 2.8 0.6 4.2 0.7 1.6 0.7 3.4 0.4 113 13 106 255 13.5 0.1 13.8 13.3 08/12/2005 06:00:00 2.7 0.5 4.2 1.5 2.5 0.5 3.8 1.1 1.8 0.6 3 0.4 107 14 96 255 14.2 0.3 15.2 13.8 08/12/2005 06:10:00 3 0.5 4.6 1.5 2.8 0.5 4.2 1.5 2 0.6 3.8 0.4 106 11 112 255 14.7 0.1 15.5 14.6 08/12/2005 06:20:00 3 0.5 4.2 1.5 2.8 0.6 4.2 1.1 2.2 0.6 3.8 0.4 108 9 111 255 15.4 0.1 16 15.2 08/12/2005 06:30:00 2.8 0.5 4.2 1.5 2.6 0.6 4.2 1.1 1.9 0.7 3.4 0.4 111 12 104 255 15.6 0 16.3 15.5 08/12/2005 06:40:00 2.4 0.6 3.8 0.4 2.1 0.6 3.8 0.4 1.5 0.7 3.4 0.4 98 16 108 255 16.4 0.3 17.1 15.7 08/12/2005 06:50:00 1.2 0.7 3 0.4 1 0.7 2.3 0.4 0.6 0.4 1.9 0.4 90 11 83 255 17.2 0.2 17.7 16.8 08/12/2005 07:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 79 7 79 255 18.3 0.3 18.8 17.7 08/12/2005 07:10:00 1.2 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 72 11 87 255 19.1 0.3 19.4 18.5 08/12/2005 07:20:00 1.4 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.6 0.4 86 12 118 255 19.8 0.1 20.5 19.4 08/12/2005 07:30:00 2 0.5 3 0.4 1.7 0.6 3 0.4 1.5 0.5 2.6 0.4 107 12 100 255 20 0 20.3 20 08/12/2005 07:40:00 0.7 0.6 2.3 0.4 0.6 0.5 2.6 0.4 0.4 0.2 1.1 0.4 110 21 81 255 20.4 0.3 21.4 20 08/12/2005 07:50:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 97 12 100 255 20.8 0 21.1 20.8 08/12/2005 08:00:00 1.3 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 59 21 60 255 21.5 0.1 22.3 21.1 08/12/2005 08:10:00 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 39 11 38 255 22 0.1 22.3 21.7 08/12/2005 08:20:00 1.5 0.4 2.6 0.7 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 5 10 5 255 22.4 0 22.6 22 08/12/2005 08:30:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 5 12 9 255 22.7 0 22.9 22.6 08/12/2005 08:40:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 15 16 17 255 22.4 0 22.9 22.3 08/12/2005 08:50:00 1.4 0.4 2.3 0.4 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 16 29 7 255 22.8 0 23.2 22.9 08/12/2005 09:00:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 30 20 15 255 22.7 0 23.5 22.6 08/12/2005 09:10:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 67 15 54 255 22.7 0 23.2 22.6 08/12/2005 09:20:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 0.6 0.4 1.5 0.4 16 17 15 255 23.3 0.2 23.8 22.9 08/12/2005 09:30:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 343 36 36 255 23.9 0.1 24.7 23.8 08/12/2005 09:40:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 334 23 294 255 24 0.1 24.4 23.8 08/12/2005 09:50:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 358 20 24 255 24.2 0 24.4 23.8 08/12/2005 10:00:00 1.7 0.5 3 0.4 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 5 24 338 255 24.1 0 24.4 23.8 08/12/2005 10:10:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 346 22 328 255 24.4 0 25 24.1 08/12/2005 10:20:00 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 1 0.6 3 0.4 345 22 4 255 24.9 0 25 24.7 08/12/2005 10:30:00 1.9 0.6 3.8 0.4 1.5 0.6 2.6 0.4 1.3 0.6 3 0.4 352 30 331 255 24.8 0 25.3 24.7 08/12/2005 10:40:00 1.6 0.8 3 0.4 1.3 0.7 3 0.4 1.1 0.7 2.6 0.4 345 29 346 255 25 0.1 25.3 24.7 08/12/2005 10:50:00 2.3 0.6 3.8 0.4 2 0.6 3.4 0.4 1.7 0.8 3.8 0.4 344 16 348 255 25.2 0 25.6 25.3 08/12/2005 11:00:00 1.5 0.8 3.4 0.4 1.3 0.8 3 0.4 0.9 0.6 2.6 0.4 322 38 305 255 25.9 0.2 26.5 25.3 08/12/2005 11:10:00 2.2 0.5 3.4 0.7 2 0.5 3 0.7 1.8 0.7 3.4 0.4 317 17 309 255 25.7 0.3 26.5 25.3 08/12/2005 11:20:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 1.2 0.7 3 0.4 308 11 305 255 25.4 0 25.9 25.3 08/12/2005 11:30:00 1.8 0.6 3 0.4 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 304 18 317 255 25.5 0 25.9 25.3 08/12/2005 11:40:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 0.9 0.6 2.6 0.4 285 36 273 255 25.8 0.3 26.5 25.3 08/12/2005 11:50:00 2 0.5 3.4 0.7 1.8 0.6 3 0.4 1.5 0.7 3 0.4 282 28 295 255 25.9 0 26.5 25.6 08/12/2005 12:00:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 1.1 0.6 3 0.4 262 12 241 255 26.2 0.1 26.5 25.9 08/12/2005 12:10:00 1.8 0.6 3.4 0.4 1.6 0.6 3.8 0.4 1 0.7 3 0.4 277 24 294 255 26.4 0 26.5 26.2 08/12/2005 12:20:00 1.8 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.1 0.6 2.6 0.4 299 36 291 255 26.9 0 27.1 26.5 08/12/2005 12:30:00 2.2 0.7 3.8 0.7 2.1 0.7 3.4 0.4 1.8 0.8 3.4 0.4 311 23 291 255 26.9 0 27.1 26.5 08/12/2005 12:40:00 2 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.2 0.7 3 0.4 311 33 315 255 27 0.1 27.4 26.5 08/12/2005 12:50:00 2 0.5 3.4 0.4 1.8 0.5 3 0.7 1.4 0.5 2.6 0.4 344 33 7 255 27 0 27.1 26.8 08/12/2005 13:00:00 1.7 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.2 0.7 3 0.4 329 45 7 255 27.4 0.2 28 27.1 08/12/2005 13:10:00 1.5 0.7 3 0.4 1.3 0.6 3 0.4 0.9 0.7 3 0.4 271 24 291 255 28 0 28 28 08/12/2005 13:20:00 2.1 0.7 3.8 0.4 1.8 0.7 3.4 0.4 1.4 0.8 3.4 0.4 323 30 334 255 28.3 0.1 28.3 28 08/12/2005 13:30:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 9 82 329 255 28.2 0 28.3 28 08/12/2005 13:40:00 2.1 0.7 3.4 0.4 2 0.7 3.4 0.4 1.7 0.8 3.4 0.4 301 27 322 255 28.3 0 28.6 28 08/12/2005 13:50:00 1.4 0.7 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 311 39 312 255 28.5 0 28.6 28.3 08/12/2005 14:00:00 1.5 0.6 3.4 0.4 1.3 0.6 3 0.4 0.9 0.5 2.3 0.4 328 41 338 255 28.4 0 29 28.3 08/12/2005 14:10:00 1.6 0.8 4.2 0.4 1.5 0.8 3.8 0.4 1.2 0.7 2.6 0.4 271 26 319 255 28.8 0.1 29.3 28.3 08/12/2005 14:20:00 1.6 0.8 3.4 0.4 1.5 0.7 3.4 0.4 1.1 0.7 3 0.4 313 28 294 255 28.7 0 29.3 28.3 08/12/2005 14:30:00 1.8 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.3 0.7 3 0.4 320 24 317 255 28.9 0 29.3 29 08/12/2005 14:40:00 1.5 0.8 3 0.4 1.4 0.7 3 0.4 1 0.7 3 0.4 311 32 291 255 28.9 0 29.3 28.6 08/12/2005 14:50:00 1.3 0.7 3 0.4 1.2 0.6 3 0.4 1 0.7 3 0.4 318 49 289 255 29.3 0 29.6 29.3 08/12/2005 15:00:00 2.2 0.7 3.8 0.4 2 0.6 3.4 0.4 1.8 0.8 3.4 0.4 321 17 347 255 29.4 0 29.3 29.3 08/12/2005 15:10:00 1.9 0.7 3.8 0.4 1.6 0.6 3.4 0.4 1 0.7 3 0.4 339 32 329 255 29.7 0 29.9 29.3 08/12/2005 15:20:00 2.3 0.7 4.2 0.4 2.2 0.7 4.2 0.4 1.7 0.7 3.4 0.4 298 28 301 255 29.4 0.1 29.9 29.3 08/12/2005 15:30:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.3 0.7 3.4 0.4 303 17 274 255 29.2 0.1 29.6 29 08/12/2005 15:40:00 1.4 0.8 3 0.4 1.4 0.8 2.6 0.4 1 0.7 3 0.4 318 39 310 255 29.5 0.1 29.9 29.3 08/12/2005 15:50:00 1.9 0.7 3.8 0.4 1.8 0.7 3.4 0.4 1.2 0.8 3.8 0.4 303 33 294 255 29.6 0 29.9 29.3 08/12/2005 16:00:00 2 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.5 0.8 3.4 0.4 293 19 307 255 29.4 0 29.6 29.3 08/12/2005 16:10:00 2.1 0.8 4.2 0.4 2 0.8 4.2 0.4 1.6 0.8 4.2 0.4 294 22 290 255 29.4 0 29.3 29.3 08/12/2005 16:20:00 2 0.6 3.4 0.4 1.8 0.6 3 0.4 1.3 0.9 3.8 0.4 312 21 331 255 29.3 0 29.3 29 08/12/2005 16:30:00 2.1 0.7 3.4 0.4 1.7 0.5 3 0.4 1.5 0.8 3.4 0.4 330 17 351 255 28.4 0.1 29 28.3 08/12/2005 16:40:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 0.9 0.6 2.6 0.4 317 22 302 255 28 0 28.3 27.7 08/12/2005 16:50:00 2 0.5 3 0.4 1.8 0.5 3 0.4 1.3 0.6 2.6 0.4 317 20 311 255 27.5 0 27.7 27.4 08/12/2005 17:00:00 1.9 0.4 3 0.7 1.6 0.4 2.6 0.7 1.2 0.6 2.6 0.4 317 29 323 255 27.2 0 27.4 27.1 08/12/2005 17:10:00 2.1 0.5 3 0.4 2 0.5 3 0.4 1.6 0.7 3 0.4 280 14 304 255 27.1 0 27.1 27.1 08/12/2005 17:20:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.1 0.8 3 0.4 291 19 289 255 26.7 0 27.1 26.5 08/12/2005 17:30:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.6 0.4 329 27 30 255 26.6 0 26.8 26.5 08/12/2005 17:40:00 2 0.6 3 0.4 1.7 0.5 3 0.4 1.2 0.7 2.6 0.4 333 17 350 255 26.1 0 26.5 25.9 08/12/2005 17:50:00 1.4 0.5 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 328 16 323 255 25.9 0 26.2 25.6 08/12/2005 18:00:00 1.4 0.7 3 0.4 1.2 0.7 3 0.4 0.8 0.6 2.6 0.4 313 20 304 255 25.8 0 26.2 25.6 08/12/2005 18:10:00 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 1.1 0.6 2.6 0.4 302 17 300 255 25.6 0 26.2 25.6 08/12/2005 18:20:00 1.8 0.5 2.6 0.4 1.3 0.4 2.3 0.4 1 0.5 2.3 0.4 335 10 317 255 25.2 0.1 25.6 25 08/12/2005 18:30:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 342 18 339 255 24.7 0.1 25.3 24.4 08/12/2005 18:40:00 2.3 0.4 3.4 1.1 2 0.5 3.4 0.7 1.2 0.6 2.6 0.4 349 9 6 255 24.4 0 24.7 24.1 08/12/2005 18:50:00 2.3 0.6 3.4 0.4 2.2 0.6 3.4 0.7 1.1 0.6 3.4 0.4 11 18 347 255 23.9 0 24.4 23.8 08/12/2005 19:00:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.1 0.6 3.4 0.7 32 9 39 255 23.8 0 23.8 23.8 08/12/2005 19:10:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.7 1.3 0.8 3 0.4 14 9 21 255 23.5 0 23.8 23.2 08/12/2005 19:20:00 2.3 0.5 3.4 0.4 2.1 0.5 3 0.7 1.7 0.6 3 0.4 54 13 52 255 23.3 0 23.5 23.2 08/12/2005 19:30:00 2.5 0.3 3 1.5 2.4 0.3 3 1.5 1.8 0.5 2.6 0.4 55 8 53 255 23.5 0 23.8 23.5 08/12/2005 19:40:00 2.3 0.4 3 1.1 2.1 0.4 3 0.7 1.4 0.6 2.6 0.4 61 11 49 255 23.3 0.2 23.8 22.9 08/12/2005 19:50:00 2.5 0.4 3.8 1.5 2.5 0.4 3.4 1.5 1.8 0.6 3.4 0.4 62 9 57 255 22.6 0 23.5 22.3 08/12/2005 20:00:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.5 1.9 0.6 3.4 0.4 52 13 47 255 22.2 0.1 22.9 21.7 08/12/2005 20:10:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1 0.6 2.3 0.4 47 13 37 255 21.6 0.3 22.6 20.8 08/12/2005 20:20:00 2.4 0.5 4.2 1.1 2.3 0.5 3.8 1.1 1.6 0.5 3 0.4 51 15 67 255 20.4 0 21.1 20.3 08/12/2005 20:30:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.5 1.9 0.6 3.4 0.4 42 8 37 255 20.3 0 20.8 20.3 08/12/2005 20:40:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.6 0.5 3 0.4 59 10 53 255 19.7 0.3 20.8 19.1 08/12/2005 20:50:00 2.5 0.3 3.4 1.9 2.4 0.4 3.4 1.5 1.6 0.5 2.6 0.4 63 6 58 255 19.4 0 19.4 19.1 08/12/2005 21:00:00 2.3 0.5 3 1.1 2.2 0.5 3 1.1 1 0.6 2.6 0.4 70 10 58 255 18.7 0.3 19.4 18 08/12/2005 21:10:00 1.9 0.4 3 1.1 1.8 0.4 3 1.1 1 0.4 1.9 0.4 68 8 67 255 17.8 0 18.2 17.7 08/12/2005 21:20:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 1.3 0.4 2.3 0.4 82 7 78 255 17.5 0.1 17.7 17.1 08/12/2005 21:30:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 1.4 0.4 2.3 0.4 88 9 91 255 17.2 0 17.4 16.8 08/12/2005 21:40:00 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.1 1.3 0.6 2.6 0.4 78 12 93 255 16.7 0 16.8 16.6 08/12/2005 21:50:00 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.5 1.7 0.5 3 0.4 65 11 62 255 17 0.1 17.4 16.8 08/12/2005 22:00:00 2.7 0.8 4.6 0.7 2.6 0.8 4.6 1.1 1.6 0.9 3.8 0.4 60 16 55 255 17.6 0 17.7 17.1 08/12/2005 22:10:00 2.6 0.8 4.6 0.7 2.5 0.8 4.2 0.4 1.6 0.7 3.4 0.4 66 16 69 255 17.7 0 17.7 17.4 08/12/2005 22:20:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.4 0.5 2.3 0.4 66 13 59 255 17.7 0 18.2 17.4 08/12/2005 22:30:00 2.4 0.6 4.2 1.1 2.3 0.6 3.8 0.7 1.4 0.6 3 0.4 59 15 89 255 17.5 0 18 17.4 08/12/2005 22:40:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.4 1.3 0.6 2.6 0.4 51 13 44 255 17.1 0 17.4 16.8 08/12/2005 22:50:00 1.7 0.5 3 0.4 1.6 0.5 3 0.7 0.7 0.5 2.3 0.4 59 16 89 255 16.4 0.2 16.8 15.7 08/12/2005 23:00:00 1.9 0.7 3.8 0.4 1.8 0.7 3.8 0.4 0.9 0.6 3 0.4 52 15 54 255 15.6 0.1 16 15.2 08/12/2005 23:10:00 2.2 0.4 3 1.1 2 0.5 3 0.7 1.1 0.5 2.3 0.4 56 14 52 255 15.2 0.1 15.7 14.9 08/12/2005 23:20:00 2.1 0.5 3.4 1.1 2 0.5 3 0.7 1.1 0.5 2.6 0.4 63 13 68 255 15 0 15.5 14.6 08/12/2005 23:30:00 2 0.5 3.4 0.7 1.9 0.5 3 0.7 1 0.6 2.3 0.4 53 10 60 255 15 0 15.5 14.6 08/12/2005 23:40:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 0.7 0.4 1.9 0.4 55 6 66 255 14.7 0.1 15.2 14.6 08/12/2005 23:50:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.7 0.4 1.9 0.4 59 12 53 255 14.4 0.2 14.9 13.8 08/13/2005 00:00:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 70 7 68 255 14 0.2 14.6 13.8 08/13/2005 00:10:00 1.3 0.3 1.9 0.4 1 0.3 1.9 0.4 0.4 0 0.7 0.4 58 1 61 255 13.9 0.1 14.6 13.8 08/13/2005 00:20:00 1.5 0.4 2.3 0.4 1.2 0.5 1.9 0.4 0.6 0.3 1.1 0.4 67 9 74 255 13.9 0 14.6 13.8 08/13/2005 00:30:00 2 0.3 2.6 1.1 1.8 0.3 2.6 0.7 1 0.3 1.9 0.4 77 4 73 255 13.7 0.1 14.4 13.3 08/13/2005 00:40:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 0.4 0 0.4 0.4 64 0 64 255 13.3 0 13.8 13 08/13/2005 00:50:00 1.3 0.4 1.9 0.4 1 0.5 1.9 0.4 0.4 0 0.4 0.4 64 0 64 255 13.3 0 13.5 13 08/13/2005 01:00:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 67 1 68 255 13.2 0 13.5 13 08/13/2005 01:10:00 1.7 0.2 2.3 1.1 1.5 0.3 2.3 0.7 0.5 0.2 1.1 0.4 73 6 74 255 13.1 0 13.5 13 08/13/2005 01:20:00 2 0.3 3 1.5 1.9 0.3 2.6 1.1 0.9 0.4 1.9 0.4 81 7 77 255 12.9 0.1 13.3 12.7 08/13/2005 01:30:00 2.1 0.4 3 1.1 1.9 0.4 3 0.7 0.9 0.4 1.9 0.4 71 8 66 255 12.8 0 13.3 12.5 08/13/2005 01:40:00 2.1 0.5 3.4 1.1 2 0.5 3.4 1.1 0.8 0.5 2.3 0.4 67 7 68 255 12.5 0 12.7 12.5 08/13/2005 01:50:00 2 0.4 3 0.7 1.9 0.5 3 0.7 0.7 0.4 1.5 0.4 67 10 69 255 12.4 0.1 12.7 12.5 08/13/2005 02:00:00 2.1 0.4 3 1.5 2 0.4 2.6 1.1 0.9 0.4 2.3 0.4 58 7 63 255 12.4 0.1 12.7 12.2 08/13/2005 02:10:00 2.2 0.4 3 1.5 2 0.4 3 1.1 0.8 0.4 1.9 0.4 55 7 63 255 12.4 0 12.7 12.2 08/13/2005 02:20:00 1.9 0.4 3 0.7 1.7 0.4 3 0.7 0.4 0.2 1.1 0.4 67 8 80 255 12.3 0 12.7 12.2 08/13/2005 02:30:00 1.9 0.4 3 0.7 1.7 0.4 2.6 0.7 0.5 0.3 1.5 0.4 61 8 43 255 12.3 0 12.7 12.2 08/13/2005 02:40:00 1.7 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.4 0.1 1.1 0.4 56 10 71 255 12.3 0 12.7 12.2 08/13/2005 02:50:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 46 0 46 255 12.3 0 12.7 12.2 08/13/2005 03:00:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 48 9 46 255 12.3 0 12.7 12.2 08/13/2005 03:10:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 75 0 75 255 12.2 0 12.7 12.2 08/13/2005 03:20:00 1.5 0.3 2.3 0.7 1.1 0.4 2.3 0.4 0.4 0 0.4 0.4 80 6 90 255 12 0 12.5 11.9 08/13/2005 03:30:00 2.1 0.2 2.6 1.5 1.9 0.3 2.6 1.1 0.6 0.3 1.5 0.4 90 0 90 255 11.9 0 12.5 11.9 08/13/2005 03:40:00 2 0.2 2.6 1.1 1.8 0.3 2.3 1.1 0.6 0.3 1.1 0.4 86 8 91 255 11.8 0 12.2 11.7 08/13/2005 03:50:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.5 0.3 1.5 0.4 65 7 84 255 11.7 0 12.2 11.7 08/13/2005 04:00:00 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.5 0.3 1.5 0.4 68 5 57 255 11.7 0 12.2 11.7 08/13/2005 04:10:00 1.9 0.3 2.6 1.1 1.6 0.3 2.6 0.7 0.6 0.4 1.5 0.4 61 9 68 255 11.9 0 12.2 11.7 08/13/2005 04:20:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 0.4 0 0.4 0.4 61 7 71 255 11.9 0 12.5 11.7 08/13/2005 04:30:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 0.4 0 0.4 0.4 64 9 45 255 11.7 0 12.2 11.7 08/13/2005 04:40:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 0.4 0 0.4 0.4 53 9 64 255 11.5 0 11.7 11.4 08/13/2005 04:50:00 1.2 0.5 2.3 0.4 0.7 0.6 2.3 0.4 0.4 0 0.4 0.4 65 3 64 255 11.3 0 11.7 11.1 08/13/2005 05:00:00 2.9 0.4 3.8 1.9 2.7 0.4 3.4 1.9 1.2 0.5 2.3 0.4 90 7 96 255 11.2 0 11.7 11.1 08/13/2005 05:10:00 2.7 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.2 0.6 2.6 0.4 91 9 91 255 11.3 0.1 11.7 11.1 08/13/2005 05:20:00 2 0.3 3 1.5 1.7 0.3 2.6 0.7 0.6 0.3 1.5 0.4 92 6 99 255 11.5 0 11.9 11.4 08/13/2005 05:30:00 2.1 0.3 2.6 1.1 1.8 0.3 2.6 0.7 0.7 0.4 1.5 0.4 106 9 110 255 11.7 0 12.2 11.7 08/13/2005 05:40:00 2.3 0.3 3.4 1.9 2.1 0.3 3 1.5 1.1 0.4 1.9 0.4 97 11 83 255 12.1 0 12.7 11.9 08/13/2005 05:50:00 1.7 0.3 2.6 0.7 1.4 0.4 2.6 0.4 0.5 0.3 1.5 0.4 111 13 97 255 12.3 0 12.2 12.2 08/13/2005 06:00:00 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 127 8 127 255 12.5 0.1 13 12.2 08/13/2005 06:10:00 1.5 0.4 2.3 0.4 1.1 0.5 1.9 0.4 0.4 0.1 1.1 0.4 105 10 111 255 12.8 0 13.3 12.7 08/13/2005 06:20:00 2 0.3 2.6 1.1 1.8 0.3 2.6 1.1 0.7 0.4 1.9 0.4 101 5 106 255 13.5 0 13.5 13 08/13/2005 06:30:00 1.9 0.5 3.4 1.1 1.7 0.5 3.4 0.7 0.9 0.5 2.3 0.4 92 9 71 255 13.7 0 14.1 13.5 08/13/2005 06:40:00 1.9 0.6 3 0.4 1.7 0.7 3 0.4 0.9 0.5 1.9 0.4 84 9 71 255 14.6 0.4 15.5 13.8 08/13/2005 06:50:00 1.6 0.3 2.6 0.7 1.3 0.4 2.3 0.4 0.7 0.3 1.5 0.4 84 9 90 255 15.3 0.1 16 15.2 08/13/2005 07:00:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 68 13 80 255 16.8 0.4 17.7 16 08/13/2005 07:10:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 61 13 66 255 18.2 0.3 18.8 17.4 08/13/2005 07:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 58 19 65 255 19.1 0.3 19.7 18.5 08/13/2005 07:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 8 20 27 255 19.5 0 19.7 19.4 08/13/2005 07:40:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.9 0.4 8 14 6 255 20.1 0.3 21.1 19.4 08/13/2005 07:50:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.5 2.3 0.4 37 10 27 255 20.8 0.1 21.1 20.5 08/13/2005 08:00:00 1.8 0.3 2.6 0.7 1.6 0.3 2.3 0.7 1 0.5 1.9 0.4 25 20 36 255 20.6 0 21.1 20.5 08/13/2005 08:10:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1.2 0.5 2.3 0.4 20 15 17 255 21.1 0 21.7 20.8 08/13/2005 08:20:00 1.6 0.5 2.6 0.4 1.4 0.5 2.3 0.4 0.8 0.6 2.3 0.4 8 13 7 255 21 0 21.1 20.8 08/13/2005 08:30:00 1.4 0.5 2.3 0.4 1.2 0.6 2.3 0.4 0.9 0.5 2.3 0.4 13 13 15 255 21.6 0.2 22 21.1 08/13/2005 08:40:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 2 22 15 255 21.9 0 22.6 21.7 08/13/2005 08:50:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1 0.6 2.3 0.4 333 13 343 255 21.6 0 22.3 21.1 08/13/2005 09:00:00 1.6 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.8 0.5 2.3 0.4 354 17 19 255 21.7 0.2 22.3 21.4 08/13/2005 09:10:00 1.6 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 343 15 343 255 22 0.2 22.6 21.7 08/13/2005 09:20:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 359 14 1 255 22 0 22.6 21.7 08/13/2005 09:30:00 1.2 0.6 2.3 0.4 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 340 24 337 255 22.3 0.2 22.9 21.7 08/13/2005 09:40:00 1.2 0.5 2.6 0.4 1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 311 21 310 255 22.7 0 23.2 22.3 08/13/2005 09:50:00 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 308 20 315 255 22.8 0 23.2 22.9 08/13/2005 10:00:00 2 0.5 3 0.4 1.7 0.5 3 0.4 1.5 0.7 2.6 0.4 310 21 295 255 22.7 0 23.2 22.6 08/13/2005 10:10:00 2 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.4 0.6 3 0.4 316 20 313 255 22.8 0 22.9 22.6 08/13/2005 10:20:00 2.1 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.4 0.8 3 0.4 315 24 311 255 23 0 23.5 22.9 08/13/2005 10:30:00 1.7 0.7 3 0.4 1.5 0.6 3 0.4 1 0.6 2.6 0.4 310 23 309 255 23.7 0.2 24.1 23.2 08/13/2005 10:40:00 2 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.4 0.9 3.4 0.4 306 22 309 255 23.5 0 23.8 23.5 08/13/2005 10:50:00 2.2 0.6 3.8 0.4 2 0.6 3.8 0.4 1.5 0.6 3.4 0.4 315 22 297 255 23.8 0 23.8 23.5 08/13/2005 11:00:00 2.3 0.6 3.4 0.7 2.1 0.7 3.4 0.4 1.8 0.8 3.8 0.4 297 24 300 255 23.8 0.1 24.1 23.5 08/13/2005 11:10:00 1.8 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.1 0.7 3.4 0.4 270 47 339 255 24 0 24.4 23.8 08/13/2005 11:20:00 2.5 0.8 4.6 0.7 2.2 0.9 4.2 0.4 1.8 0.9 4.2 0.4 328 24 313 255 24.1 0 24.7 23.8 08/13/2005 11:30:00 2.5 0.7 4.2 0.7 2.3 0.8 3.8 0.4 1.9 0.7 3.8 0.4 315 20 308 255 24.3 0 24.7 24.1 08/13/2005 11:40:00 2.4 0.6 4.2 0.4 2.2 0.7 4.2 0.4 1.9 0.7 3.8 0.4 328 29 350 255 24.7 0 25 24.4 08/13/2005 11:50:00 1.8 0.7 3.8 0.4 1.4 0.7 3 0.4 1 0.7 3 0.4 332 29 347 255 24.9 0 25 24.7 08/13/2005 12:00:00 2.5 0.7 4.2 0.4 2.4 0.7 4.2 0.4 1.9 0.8 3.8 0.4 301 27 323 255 25.2 0 25.3 25 08/13/2005 12:10:00 2.7 0.7 4.6 1.1 2.5 0.7 4.2 1.1 2 0.8 4.6 0.4 313 27 291 255 25.1 0 25.3 25 08/13/2005 12:20:00 2.7 0.7 4.6 1.1 2.5 0.8 4.6 0.4 2 0.9 4.2 0.4 300 27 294 255 25.1 0 25.6 25 08/13/2005 12:30:00 3.3 0.7 5.3 1.5 3.1 0.7 4.6 1.1 2.7 1 4.9 0.4 291 17 267 255 24.9 0 25.3 24.7 08/13/2005 12:40:00 2.5 0.9 4.6 0.4 2.3 1 4.9 0.4 1.8 1.1 4.6 0.4 295 29 293 255 24.6 0.3 25.6 24.4 08/13/2005 12:50:00 2.2 1.1 4.2 0.4 2.1 1.1 4.2 0.4 1.7 1 3.8 0.4 296 43 232 255 26 0.1 26.2 25.6 08/13/2005 13:00:00 1.8 0.8 4.2 0.4 1.7 0.7 4.2 0.4 1.2 0.9 3.8 0.4 288 29 295 255 26 0 26.2 25.9 08/13/2005 13:10:00 1.7 0.8 3.4 0.4 1.6 0.7 3 0.4 1.1 0.6 3 0.4 298 45 352 255 26 0.3 26.5 25.6 08/13/2005 13:20:00 2.2 0.8 3.8 0.4 2 0.7 3.8 0.4 1.4 0.7 3 0.4 325 38 322 255 26.6 0 26.8 26.5 08/13/2005 13:30:00 2.6 0.9 4.9 0.4 2.3 0.9 4.2 0.4 1.7 0.9 3.8 0.4 326 32 343 255 27.1 0.2 27.4 26.5 08/13/2005 13:40:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 0.7 2 0.6 3.4 0.4 332 22 328 255 26.6 0 26.5 26.5 08/13/2005 13:50:00 2.5 0.7 4.2 0.4 2.2 0.7 4.2 0.4 1.8 0.9 4.2 0.4 312 33 309 255 26.8 0.2 27.4 26.5 08/13/2005 14:00:00 2.8 0.6 3.8 1.1 2.6 0.7 4.2 0.7 2 0.9 3.8 0.4 323 22 307 255 27 0 27.4 26.8 08/13/2005 14:10:00 2.3 0.7 4.2 0.4 2.1 0.7 3.8 0.4 1.6 0.9 3.8 0.4 309 30 296 255 27.3 0 27.4 27.1 08/13/2005 14:20:00 1.8 1.1 4.2 0.4 1.7 1 3.8 0.4 1.5 1 3.8 0.4 306 38 302 255 27.3 0.2 27.7 27.1 08/13/2005 14:30:00 1.6 0.7 3.4 0.4 1.5 0.6 3.4 0.4 0.9 0.7 3 0.4 307 21 289 255 27.2 0.2 27.7 26.8 08/13/2005 14:40:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.4 0.9 3.4 0.4 288 35 277 255 27.6 0 28 27.4 08/13/2005 14:50:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1 0.6 3 0.4 274 51 223 255 27.6 0.1 28 27.4 08/13/2005 15:00:00 1.4 1 3.4 0.4 1.3 0.9 3.4 0.4 1.1 0.8 3.8 0.4 285 61 292 255 28.1 0 28.3 28 08/13/2005 15:10:00 2 0.8 3.4 0.4 1.9 0.7 3 0.4 1.4 0.9 3 0.4 294 27 317 255 27.4 0.2 28 27.1 08/13/2005 15:20:00 2 1 4.2 0.4 1.8 0.9 4.2 0.4 1.4 0.9 3.4 0.4 299 38 305 255 27.7 0 28 27.7 08/13/2005 15:30:00 2 0.8 3.4 0.4 1.8 0.8 3 0.4 1.2 0.8 3 0.4 303 26 307 255 27.6 0 28 27.4 08/13/2005 15:40:00 1.8 0.8 3.8 0.4 1.6 0.9 3.4 0.4 1.3 0.8 3 0.4 277 35 261 255 27.6 0 28 27.4 08/13/2005 15:50:00 2 0.6 3.8 0.4 1.7 0.7 3 0.4 1.3 0.7 3.4 0.4 295 32 334 255 27.6 0 28 27.4 08/13/2005 16:00:00 1.9 0.6 3.8 0.7 1.7 0.8 3.4 0.4 1.4 0.8 3.8 0.4 303 22 272 255 27.3 0.1 27.7 27.1 08/13/2005 16:10:00 1.8 0.5 3.4 0.4 1.5 0.6 3 0.4 1 0.6 2.6 0.4 296 29 300 255 27.3 0.1 27.7 27.1 08/13/2005 16:20:00 1.4 0.8 3 0.4 1.2 0.7 3 0.4 1 0.7 2.6 0.4 290 24 273 255 27 0 27.1 27.1 08/13/2005 16:30:00 2.2 0.5 3.8 0.4 2 0.6 3.4 0.4 1.6 0.7 3 0.4 287 26 255 255 26.4 0.3 27.1 26.2 08/13/2005 16:40:00 2.1 0.7 3.8 0.4 2 0.6 3.8 0.4 1.7 0.7 3.4 0.4 289 15 277 255 25.7 0.1 26.2 25.6 08/13/2005 16:50:00 1.9 0.8 3.8 0.4 1.8 0.7 3.4 0.4 1.5 0.8 3.8 0.4 281 24 265 255 25.4 0 25.6 25.3 08/13/2005 17:00:00 1.9 0.8 3.8 0.4 1.8 0.7 3.8 0.4 1.3 0.8 3.4 0.4 304 22 301 255 25.1 0 25.3 25 08/13/2005 17:10:00 2.2 0.5 3.4 0.4 2.1 0.5 3.4 0.7 1.8 0.8 3.4 0.4 294 18 259 255 24.9 0 25.3 24.7 08/13/2005 17:20:00 2.3 0.5 3.8 0.7 2.2 0.5 3.4 0.4 1.5 0.7 3.4 0.4 295 14 303 255 24.7 0 25 24.7 08/13/2005 17:30:00 2 0.5 3.4 0.4 1.8 0.6 3 0.4 1.5 0.7 3 0.4 285 17 298 255 24.7 0 25 24.7 08/13/2005 17:40:00 1.8 0.6 3 0.7 1.6 0.7 3 0.4 1.2 0.7 3 0.4 294 18 289 255 24.5 0 25 24.4 08/13/2005 17:50:00 2.3 0.4 3.4 1.1 2.2 0.5 3.4 1.1 1.6 0.8 3 0.4 298 11 294 255 24.4 0 25 24.1 08/13/2005 18:00:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 2 0.5 3 0.4 298 8 302 255 24.2 0 24.4 24.1 08/13/2005 18:10:00 1.9 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1.3 0.5 2.6 0.4 290 17 322 255 24.1 0.1 24.4 23.8 08/13/2005 18:20:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 291 5 293 255 23.8 0 24.1 23.8 08/13/2005 18:30:00 1.6 0.4 2.6 0.4 1.4 0.4 2.6 0.4 1.1 0.5 2.3 0.4 284 10 275 255 23.7 0 23.8 23.5 08/13/2005 18:40:00 1.5 0.4 2.3 0.4 1.3 0.4 1.9 0.4 0.8 0.4 1.9 0.4 284 12 270 255 23.3 0 23.5 22.9 08/13/2005 18:50:00 1.5 0.4 2.3 0.4 1.1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 302 11 305 255 22.9 0.1 23.5 22.6 08/13/2005 19:00:00 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.7 0.4 1.9 0.4 281 9 303 255 22.4 0 22.9 22.3 08/13/2005 19:10:00 1.7 0.4 2.3 0.4 1.4 0.5 2.3 0.4 0.8 0.5 1.9 0.4 292 5 295 255 22.2 0 22.9 22 08/13/2005 19:20:00 1.9 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1 0.5 2.3 0.4 295 6 300 255 21.8 0.2 22.3 21.4 08/13/2005 19:30:00 2.2 0.4 3 0.7 2 0.5 3 0.7 1.5 0.5 2.6 0.4 293 7 289 255 21.3 0.1 22 21.1 08/13/2005 19:40:00 2.1 0.5 3.4 0.4 1.9 0.6 3.4 0.4 1.2 0.6 2.6 0.4 284 14 275 255 21.1 0 21.4 20.8 08/13/2005 19:50:00 2.1 0.5 3 0.7 1.8 0.6 3 0.4 1.1 0.6 2.6 0.4 279 17 280 255 20.8 0.2 21.4 20.5 08/13/2005 20:00:00 2 0.4 3 1.1 1.9 0.5 3 0.7 1 0.5 2.3 0.4 268 12 267 255 20.5 0 21.1 20.5 08/13/2005 20:10:00 1.2 0.7 3 0.4 1 0.6 3 0.4 0.5 0.4 1.9 0.4 289 39 260 255 20.4 0 20.8 20.3 08/13/2005 20:20:00 1.9 0.4 3.4 0.7 1.5 0.5 3 0.4 1 0.6 3.4 0.4 331 22 297 255 19.8 0.2 20.5 19.4 08/13/2005 20:30:00 2.5 0.9 4.2 0.4 2.4 0.9 4.2 0.4 1.3 0.8 3.4 0.4 268 16 270 255 19.5 0 20 19.4 08/13/2005 20:40:00 2 0.7 3.4 0.4 1.9 0.6 3.4 0.4 1 0.6 3 0.4 272 15 279 255 19.2 0.1 20 18.8 08/13/2005 20:50:00 1.5 0.6 2.6 0.4 1.4 0.5 3 0.4 0.6 0.4 1.9 0.4 241 16 253 255 18.7 0.1 19.1 18.2 08/13/2005 21:00:00 1.3 0.6 3.4 0.4 1.1 0.6 3 0.4 0.6 0.4 2.3 0.4 249 6 252 255 18.2 0 18.5 18 08/13/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 248 0 255 255 17.7 0.1 18 17.4 08/13/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 330 29 255 255 17.1 0 17.4 16.8 08/13/2005 21:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 340 0 255 255 16.7 0 16.8 16.6 08/13/2005 21:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 340 0 340 255 16.4 0.1 16.8 16.3 08/13/2005 21:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 340 0 255 255 16.1 0 16.3 16 08/13/2005 22:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 330 17 293 255 15.8 0 16 15.7 08/13/2005 22:10:00 1.2 0.2 1.5 0.4 1.2 0.2 1.5 0.7 0.4 0.1 0.7 0.4 293 0 293 255 15.6 0 16.3 15.7 08/13/2005 22:20:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.7 0.4 289 12 274 255 15.5 0 15.7 15.2 08/13/2005 22:30:00 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 262 16 273 255 15.2 0 15.5 15.2 08/13/2005 22:40:00 1.3 0.5 3 0.4 1.3 0.5 2.6 0.4 0.4 0.3 1.9 0.4 252 9 261 255 15.1 0 15.7 15.2 08/13/2005 22:50:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 0.5 0.3 1.9 0.4 248 17 252 255 15 0 15.5 14.9 08/13/2005 23:00:00 1.1 0.7 3 0.4 1.1 0.6 3 0.4 0.5 0.3 1.9 0.4 246 8 255 255 14.9 0 15.2 14.6 08/13/2005 23:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 258 14 277 255 14.6 0.1 15.2 14.4 08/13/2005 23:20:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 0.4 0.2 1.1 0.4 223 10 227 255 14.4 0 14.9 14.4 08/13/2005 23:30:00 1.4 0.5 2.6 0.4 1.4 0.4 2.6 0.7 0.4 0.1 1.1 0.4 221 6 226 255 14.4 0.2 14.9 14.1 08/13/2005 23:40:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.4 0 0.7 0.4 224 3 218 255 14.1 0.2 14.6 13.8 08/13/2005 23:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 228 0 228 255 13.8 0 14.6 13.5 08/14/2005 00:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 242 27 255 255 13.7 0 13.8 13.5 08/14/2005 00:10:00 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 304 9 297 255 13.6 0 13.8 13.5 08/14/2005 00:20:00 1 0.4 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0 0.7 0.4 313 5 315 255 13.5 0.1 13.8 13.3 08/14/2005 00:30:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.6 0.4 1.9 0.4 294 3 293 255 13.3 0 13.8 13 08/14/2005 00:40:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 0.5 0.3 1.5 0.4 284 8 288 255 13.4 0 13.8 13.3 08/14/2005 00:50:00 1.5 0.5 2.3 0.4 1.4 0.4 2.3 0.4 0.5 0.2 1.1 0.4 289 11 289 255 13.5 0.1 14.1 13.3 08/14/2005 01:00:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.4 0.2 1.5 0.4 310 4 305 255 13.8 0.1 14.4 13.5 08/14/2005 01:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 308 10 328 255 14 0 14.4 13.8 08/14/2005 01:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 303 3 304 255 14.2 0 14.6 14.1 08/14/2005 01:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 292 12 238 255 14.4 0 14.9 14.4 08/14/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 14.5 0 15.2 14.6 08/14/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 14.5 0 15.2 14.6 08/14/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 14.6 0 15.2 14.6 08/14/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 14.6 0 15.2 14.6 08/14/2005 02:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 304 16 333 255 14.6 0 15.2 14.6 08/14/2005 02:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 333 0 333 255 14.6 0 15.2 14.6 08/14/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 333 0 255 255 14.5 0 15.2 14.6 08/14/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 333 0 255 255 14.5 0 15.2 14.6 08/14/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 326 12 314 255 14.5 0 14.9 14.4 08/14/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 298 0 255 255 14.4 0 14.9 14.4 08/14/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 14.3 0 14.9 14.4 08/14/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 14.2 0 14.9 14.4 08/14/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 14.2 0 14.9 14.4 08/14/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 281 30 255 255 14.3 0 14.6 14.4 08/14/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 167 6 255 255 14.3 0 14.6 14.4 08/14/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 58 255 255 14.3 0 14.6 14.1 08/14/2005 04:20:00 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 304 0 304 255 14.2 0.1 14.6 14.1 08/14/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 304 0 255 255 14.2 0.1 14.6 14.1 08/14/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 304 0 255 255 14.2 0.1 14.6 14.1 08/14/2005 04:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 323 19 337 255 14 0.1 14.6 13.8 08/14/2005 05:00:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 344 7 340 255 13.9 0 14.6 13.8 08/14/2005 05:10:00 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 352 12 348 255 13.7 0.1 14.1 13.3 08/14/2005 05:20:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 13 10 5 255 13.5 0 13.8 13.3 08/14/2005 05:30:00 1.4 0.3 2.3 0.7 1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 349 6 342 255 13.4 0 13.8 13.3 08/14/2005 05:40:00 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 345 11 352 255 13.3 0 13.5 13 08/14/2005 05:50:00 1.2 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 4 17 31 255 13.1 0.1 13.5 13 08/14/2005 06:00:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 354 11 336 255 13.1 0 13.5 13 08/14/2005 06:10:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 351 0 351 255 13.1 0 13.5 13 08/14/2005 06:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 357 9 12 255 13.1 0 13.3 13 08/14/2005 06:30:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 12 1 8 255 13.2 0 13.5 13 08/14/2005 06:40:00 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 3 16 16 255 13.2 0 13.5 13 08/14/2005 06:50:00 0.9 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 357 4 354 255 13.4 0 13.8 13.3 08/14/2005 07:00:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.5 0.4 24 13 18 255 13.3 0 13.8 13.3 08/14/2005 07:10:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 27 15 356 255 13.5 0 13.8 13.3 08/14/2005 07:20:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 9 7 12 255 13.5 0 13.8 13.3 08/14/2005 07:30:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 16 5 11 255 13.5 0 13.8 13.3 08/14/2005 07:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 2 21 255 13.7 0 13.8 13.5 08/14/2005 07:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 24 1 24 255 13.9 0 14.1 13.5 08/14/2005 08:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 23 0 23 255 14 0 14.6 13.8 08/14/2005 08:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 22 3 23 255 14.2 0 14.6 13.8 08/14/2005 08:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 346 15 8 255 14.4 0 14.9 14.4 08/14/2005 08:30:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 358 14 337 255 14.6 0 15.2 14.6 08/14/2005 08:40:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 1 15 21 255 14.7 0.1 15.2 14.6 08/14/2005 08:50:00 1.5 0.3 2.3 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.9 0.4 334 7 333 255 15 0.1 15.7 14.9 08/14/2005 09:00:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 340 6 351 255 15.4 0 16 15.2 08/14/2005 09:10:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 329 9 339 255 15.6 0 16 15.5 08/14/2005 09:20:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 348 15 323 255 15.6 0 16.3 15.5 08/14/2005 09:30:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 339 16 18 255 15.7 0 16 15.5 08/14/2005 09:40:00 1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 355 32 3 255 16 0 16.3 15.7 08/14/2005 09:50:00 1.6 0.4 3 0.4 1.2 0.5 2.6 0.4 0.9 0.5 1.9 0.4 308 20 303 255 15.9 0.1 16.6 15.7 08/14/2005 10:00:00 0.9 0.5 2.6 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 330 24 290 255 15.8 0 16.3 15.7 08/14/2005 10:10:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 333 22 4 255 16 0 16.6 16 08/14/2005 10:20:00 1.6 0.8 2.6 0.4 1.1 0.7 2.6 0.4 0.7 0.5 2.3 0.4 337 17 354 255 16.3 0.1 16.8 16 08/14/2005 10:30:00 1.7 0.5 3 0.7 1.3 0.6 3 0.4 0.9 0.6 2.6 0.4 311 19 312 255 16.4 0 16.8 16.3 08/14/2005 10:40:00 1.4 0.6 2.6 0.4 1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 282 32 305 255 16.5 0 16.8 16.3 08/14/2005 10:50:00 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 281 18 263 255 16.7 0 17.1 16.6 08/14/2005 11:00:00 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 251 11 233 255 17 0 17.1 16.8 08/14/2005 11:10:00 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 238 35 283 255 16.8 0 17.1 16.8 08/14/2005 11:20:00 0.8 0.7 2.6 0.4 0.7 0.6 2.6 0.4 0.5 0.3 2.3 0.4 286 26 322 255 17.3 0.2 17.7 16.8 08/14/2005 11:30:00 1.8 0.5 3 0.4 1.6 0.6 2.6 0.4 1.2 0.6 2.6 0.4 301 23 334 255 18.1 0 18.2 17.7 08/14/2005 11:40:00 1.9 0.8 4.2 0.4 1.6 0.9 3.8 0.4 1.2 0.8 3.8 0.4 289 27 279 255 18.4 0.2 19.1 18 08/14/2005 11:50:00 2.5 0.7 3.8 0.4 2.3 0.7 3.4 0.4 1.9 0.7 3.4 0.4 285 20 255 255 18.7 0.1 19.1 18.2 08/14/2005 12:00:00 2.3 0.5 3 0.7 2.1 0.6 3 0.4 1.6 0.7 3.4 0.4 296 15 287 255 18 0.2 18.5 17.7 08/14/2005 12:10:00 3 0.6 4.6 1.1 2.9 0.7 4.6 1.1 2.4 0.8 4.6 0.7 296 14 291 255 18.2 0.2 18.8 18 08/14/2005 12:20:00 2.5 0.7 4.6 1.1 2.3 0.7 4.2 0.4 1.4 0.8 3.4 0.4 299 22 284 255 18 0.2 18.5 17.7 08/14/2005 12:30:00 2.1 0.8 3.8 0.4 2 0.8 3.8 0.4 1.6 0.9 3.4 0.4 288 30 305 255 18.7 0.2 19.4 18.2 08/14/2005 12:40:00 2.6 0.5 4.2 1.1 2.4 0.5 4.2 0.7 2 0.6 3.8 0.4 292 21 302 255 18 0.2 18.8 17.7 08/14/2005 12:50:00 2.8 0.7 4.6 1.1 2.7 0.8 4.6 0.4 2.1 0.8 4.2 0.4 268 27 244 255 18.2 0.5 20 17.7 08/14/2005 13:00:00 2.8 0.9 4.6 0.4 2.7 0.9 4.6 0.4 2.2 1 4.6 0.4 291 22 307 255 19.2 0.4 20 18.5 08/14/2005 13:10:00 3.3 0.7 4.9 1.5 3.2 0.6 4.9 1.5 2.6 0.8 4.6 0.7 298 14 271 255 18.3 0 18.8 18 08/14/2005 13:20:00 2.7 0.8 5.3 0.4 2.6 0.8 5.3 0.4 1.8 0.9 4.6 0.4 293 32 322 255 18.5 0.1 19.4 18.2 08/14/2005 13:30:00 3.7 1.1 6.1 0.4 3.6 1.1 6.5 0.4 2.8 1.2 5.7 0.4 300 17 308 255 19 0.1 19.7 18.8 08/14/2005 13:40:00 4 0.8 6.1 1.9 3.8 0.8 5.7 1.5 3.2 1 5.3 1.5 298 16 300 255 19.7 0.2 20.5 19.4 08/14/2005 13:50:00 4.2 1 6.1 1.1 4.1 1.1 6.1 0.4 3.5 1.2 6.5 0.4 294 15 296 255 19.5 0.1 20.3 19.1 08/14/2005 14:00:00 3.7 0.8 5.3 1.5 3.5 0.8 5.7 1.5 2.8 1 4.9 0.4 299 17 268 255 18.6 0.4 19.4 18 08/14/2005 14:10:00 3.6 0.9 5.7 1.1 3.4 1 6.1 1.1 2.8 1.1 5.3 0.4 290 22 321 255 18.1 0 18.2 18 08/14/2005 14:20:00 4.3 1 6.1 1.9 4.2 1 6.1 1.9 3.5 1 6.1 0.7 283 18 287 255 17.9 0.1 18.5 17.7 08/14/2005 14:30:00 4 0.8 6.1 1.1 3.8 0.8 6.1 0.7 3.2 1.1 5.7 0.4 289 17 312 255 18.9 0.2 19.4 18.2 08/14/2005 14:40:00 3.2 1.1 5.7 0.4 3 1.2 5.3 0.4 2.6 1.2 5.3 0.4 285 22 285 255 19 0.3 19.7 18.5 08/14/2005 14:50:00 3.4 1.1 6.5 1.1 3.3 1.2 6.1 0.7 2.7 1.1 5.3 0.4 292 22 319 255 19 0.4 20 18.2 08/14/2005 15:00:00 2.6 0.7 4.9 1.1 2.4 0.8 4.6 0.4 1.8 0.9 3.8 0.4 299 32 273 255 19.7 0.2 20.5 19.4 08/14/2005 15:10:00 3.6 1 5.7 1.5 3.4 1 5.7 0.4 2.8 1.1 5.3 0.4 300 19 313 255 19.6 0.2 20.3 19.1 08/14/2005 15:20:00 4.4 0.9 6.1 1.9 4.3 1 6.5 1.9 3.8 1.3 6.5 0.7 301 13 288 255 19.2 0 19.7 19.1 08/14/2005 15:30:00 3.6 0.9 5.7 1.1 3.4 1 5.7 0.4 2.8 1.1 4.9 0.4 301 17 306 255 18.7 0.3 19.4 18 08/14/2005 15:40:00 3.4 0.8 5.3 1.1 3.2 0.9 4.9 0.7 2.5 1 4.6 0.4 295 22 303 255 17.9 0 18.2 17.7 08/14/2005 15:50:00 3.5 0.9 5.3 1.5 3.3 1 5.3 0.7 2.7 1 4.9 0.4 303 19 296 255 19 0.5 19.7 18.2 08/14/2005 16:00:00 3.4 0.8 5.3 1.5 3.2 0.8 5.3 0.7 2.6 1 5.3 0.4 310 16 315 255 19.1 0.2 19.4 18.2 08/14/2005 16:10:00 3.7 0.9 5.7 1.5 3.5 1 5.7 1.5 2.8 1.1 5.3 0.4 306 21 333 255 18 0.1 18.5 17.7 08/14/2005 16:20:00 2.8 1 4.6 0.4 2.6 0.9 4.2 0.4 1.9 1 4.6 0.4 299 30 318 255 17.8 0 18 17.4 08/14/2005 16:30:00 2.7 1 4.9 0.4 2.6 1 4.9 0.4 2.1 1.2 4.6 0.4 283 21 293 255 18.1 0.1 18.5 17.7 08/14/2005 16:40:00 3.1 1 4.9 0.4 3 1 4.6 0.4 2.6 1.1 4.6 0.4 288 22 303 255 17.4 0.2 18 17.1 08/14/2005 16:50:00 2.9 0.7 4.2 0.7 2.7 0.8 4.6 0.7 2.2 0.8 4.2 0.4 292 21 288 255 17.1 0 17.7 16.8 08/14/2005 17:00:00 3 0.7 4.6 0.4 2.9 0.7 4.6 0.4 2.2 0.9 3.8 0.4 295 12 297 255 17 0 17.4 16.8 08/14/2005 17:10:00 2.7 0.9 4.6 0.4 2.6 1 4.6 0.4 2.1 1 4.2 0.4 286 22 264 255 16.8 0 16.8 16.8 08/14/2005 17:20:00 3 0.8 4.9 1.1 2.8 0.8 4.9 0.7 2 0.9 4.2 0.4 297 21 279 255 16.9 0 17.1 16.8 08/14/2005 17:30:00 2.6 0.7 4.2 0.4 2.4 0.7 4.2 0.4 1.7 0.8 3.8 0.4 304 18 304 255 16.8 0 16.8 16.8 08/14/2005 17:40:00 2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.4 0.7 3 0.4 295 22 324 255 16.8 0 16.8 16.8 08/14/2005 17:50:00 2.5 0.7 3.8 0.7 2.3 0.7 3.8 0.4 2 0.8 3.8 0.4 291 20 295 255 16.7 0 16.8 16.8 08/14/2005 18:00:00 2.5 0.6 3.8 1.1 2.2 0.7 3.8 0.4 1.5 0.9 3.8 0.4 300 21 316 255 16.7 0 16.8 16.6 08/14/2005 18:10:00 2.5 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.7 1 3.8 0.4 291 22 287 255 16.4 0 16.8 16.3 08/14/2005 18:20:00 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 0.9 0.7 3.4 0.4 310 32 302 255 16.4 0 16.8 16.3 08/14/2005 18:30:00 2.6 0.6 3.8 0.7 2.5 0.6 3.4 1.1 1.9 0.8 3.4 0.4 279 13 292 255 16.1 0 16.6 16 08/14/2005 18:40:00 2.5 0.7 4.2 0.7 2.3 0.7 3.8 0.4 2 0.6 3.4 0.4 286 13 279 255 15.9 0 16.3 16 08/14/2005 18:50:00 1.9 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1 0.6 2.6 0.4 286 20 291 255 16 0 16.6 16 08/14/2005 19:00:00 2.9 0.5 4.2 1.5 2.7 0.6 4.2 1.1 2.1 0.8 3.8 0.4 296 9 286 255 16.1 0 16.6 16 08/14/2005 19:10:00 2.1 0.6 3.4 0.4 1.8 0.7 3 0.4 1.2 0.8 3 0.4 264 19 268 255 16.1 0 16.6 16 08/14/2005 19:20:00 2 0.5 3 0.7 1.6 0.5 3 0.4 0.8 0.5 2.3 0.4 298 20 308 255 16.1 0 16.6 16 08/14/2005 19:30:00 1.9 0.6 3 0.4 1.6 0.6 2.6 0.4 1.3 0.7 2.6 0.4 289 14 299 255 16 0 16.6 15.7 08/14/2005 19:40:00 1.7 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.8 0.6 2.3 0.4 271 12 276 255 15.7 0 16.3 15.5 08/14/2005 19:50:00 1.5 0.6 3 0.4 1.1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 275 13 283 255 15.5 0.1 16 15.2 08/14/2005 20:00:00 1.2 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 276 16 297 255 15.2 0 15.7 15.2 08/14/2005 20:10:00 1.6 0.7 3 0.4 1.3 0.7 2.6 0.4 0.7 0.5 2.3 0.4 268 16 275 255 15.2 0.1 15.7 15.2 08/14/2005 20:20:00 1.3 0.6 2.6 0.4 1 0.6 2.3 0.4 0.5 0.3 1.9 0.4 254 20 278 255 15.2 0.1 15.7 15.2 08/14/2005 20:30:00 1.5 0.6 3 0.4 1.2 0.6 2.6 0.4 0.6 0.5 2.3 0.4 250 11 253 255 15 0 15.7 14.9 08/14/2005 20:40:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 252 19 225 255 15 0 15.7 14.9 08/14/2005 20:50:00 1.2 0.8 2.6 0.4 1 0.7 2.3 0.4 0.6 0.4 2.3 0.4 296 19 318 255 15 0 15.7 14.9 08/14/2005 21:00:00 2.1 0.6 3 0.7 1.8 0.7 3 0.4 1.1 0.6 3 0.4 306 12 307 255 14.9 0 15.2 14.9 08/14/2005 21:10:00 2.1 0.5 3 0.7 1.8 0.6 2.6 0.4 1.1 0.6 2.3 0.4 304 11 308 255 14.8 0 15.2 14.9 08/14/2005 21:20:00 0.6 0.5 2.6 0.4 0.5 0.4 1.9 0.4 0.4 0.1 1.1 0.4 297 47 328 255 14.8 0 15.2 14.6 08/14/2005 21:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 287 38 276 255 14.8 0 15.2 14.6 08/14/2005 21:40:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 26 265 255 14.8 0 15.2 14.6 08/14/2005 21:50:00 1.1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.9 0.4 266 14 261 255 14.8 0 15.2 14.6 08/14/2005 22:00:00 1.3 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.3 1.9 0.4 267 12 268 255 14.8 0 15.2 14.9 08/14/2005 22:10:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 265 9 262 255 14.8 0 15.2 14.9 08/14/2005 22:20:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.4 1.9 0.4 257 10 255 255 14.8 0 15.2 14.6 08/14/2005 22:30:00 2 0.5 3 0.7 1.6 0.7 3 0.4 1 0.6 3 0.4 245 17 261 255 14.8 0 15.2 14.6 08/14/2005 22:40:00 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 0.6 0.4 1.9 0.4 259 12 251 255 14.8 0.1 15.2 14.6 08/14/2005 22:50:00 1.3 0.7 2.6 0.4 1 0.6 2.3 0.4 0.6 0.4 2.3 0.4 256 14 247 255 14.7 0.1 15.2 14.6 08/14/2005 23:00:00 0.8 0.5 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 256 21 219 255 14.7 0.1 15.2 14.6 08/14/2005 23:10:00 0.7 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 248 8 256 255 14.7 0.1 15.2 14.6 08/14/2005 23:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 254 6 279 255 14.7 0.1 15.2 14.6 08/14/2005 23:30:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 253 0 252 255 14.7 0.2 15.2 14.6 08/14/2005 23:40:00 0.8 0.6 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 254 3 253 255 14.7 0.2 15.2 14.6 08/14/2005 23:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 261 15 255 255 14.7 0.1 15.2 14.6 08/15/2005 00:00:00 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 281 11 276 255 14.6 0.1 15.2 14.6 08/15/2005 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 276 255 14.6 0.1 15.2 14.6 08/15/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 255 255 14.5 0 14.9 14.6 08/15/2005 00:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 276 255 14.5 0 15.2 14.6 08/15/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 255 255 14.5 0 14.9 14.6 08/15/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 255 255 14.5 0 14.6 14.6 08/15/2005 01:00:00 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 8 271 255 14.5 0 14.6 14.6 08/15/2005 01:10:00 1 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 0 256 255 14.5 0 14.6 14.6 08/15/2005 01:20:00 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 255 0 256 255 14.5 0 14.9 14.6 08/15/2005 01:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 14.5 0 14.9 14.4 08/15/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 14.5 0 14.6 14.4 08/15/2005 01:50:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 255 0 255 255 14.5 0 14.6 14.4 08/15/2005 02:00:00 1.2 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.2 1.1 0.4 254 2 261 255 14.5 0 14.6 14.4 08/15/2005 02:10:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 248 3 252 255 14.5 0 14.6 14.4 08/15/2005 02:20:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 247 255 14.5 0 14.9 14.4 08/15/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 255 255 14.6 0 15.2 14.6 08/15/2005 02:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 247 255 14.6 0.1 15.2 14.4 08/15/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 255 255 14.6 0 15.2 14.4 08/15/2005 03:00:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 266 23 248 255 14.6 0 15.2 14.4 08/15/2005 03:10:00 1.1 0.4 1.9 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 301 0 301 255 14.5 0 14.9 14.4 08/15/2005 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 14.6 0.1 14.9 14.4 08/15/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 14.5 0.1 14.9 14.4 08/15/2005 03:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 301 255 14.5 0 14.9 14.4 08/15/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 14.4 0 14.9 14.4 08/15/2005 04:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 307 24 40 255 14.4 0 14.9 14.4 08/15/2005 04:10:00 2.2 0.4 3 1.1 1.9 0.5 2.6 0.7 1.6 0.6 3 0.4 48 6 47 255 14.1 0.1 14.6 13.8 08/15/2005 04:20:00 1.6 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 38 6 55 255 13.7 0 13.8 13.5 08/15/2005 04:30:00 1.4 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 26 9 38 255 13.7 0 13.8 13.5 08/15/2005 04:40:00 1.3 0.3 1.9 0.7 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 15 13 15 255 13.7 0 14.1 13.5 08/15/2005 04:50:00 1.3 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 10 4 12 255 13.6 0 13.8 13.5 08/15/2005 05:00:00 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 21 3 25 255 13.5 0.1 13.8 13.5 08/15/2005 05:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 24 325 255 13.5 0.1 13.8 13.3 08/15/2005 05:20:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 325 0 325 255 13.4 0 13.8 13.3 08/15/2005 05:30:00 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 12 26 32 255 13.4 0 13.8 13.3 08/15/2005 05:40:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 66 32 52 255 13.4 0 13.8 13.3 08/15/2005 05:50:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 68 17 77 255 13.4 0 13.8 13.3 08/15/2005 06:00:00 1.8 0.5 3 0.7 1.6 0.6 3 0.4 1 0.6 2.6 0.4 71 21 61 255 13.3 0 13.8 13.3 08/15/2005 06:10:00 1.1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 65 17 73 255 13.3 0 13.8 13 08/15/2005 06:20:00 1.3 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 34 13 44 255 13.3 0 13.8 13.3 08/15/2005 06:30:00 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 14 7 11 255 13.4 0 13.8 13.3 08/15/2005 06:40:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.3 1.9 0.4 0 10 14 255 13.5 0.1 13.8 13.3 08/15/2005 06:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 354 0 354 255 13.4 0 13.8 13.3 08/15/2005 07:00:00 1.5 0.4 2.6 0.7 0.9 0.6 2.3 0.4 0.5 0.2 1.5 0.4 11 7 20 255 13.5 0.1 13.8 13.3 08/15/2005 07:10:00 1.7 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1 0.5 1.9 0.4 36 13 19 255 13.5 0 13.8 13.3 08/15/2005 07:20:00 1.1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.4 1.9 0.4 40 9 47 255 13.4 0 13.8 13.3 08/15/2005 07:30:00 1.9 0.6 3 0.7 1.4 1 3 0.4 1.1 0.7 2.6 0.4 25 7 34 255 13.5 0 14.1 13.3 08/15/2005 07:40:00 1.9 0.5 3 0.7 1.6 0.6 3 0.4 1.2 0.7 2.6 0.4 41 16 17 255 13.7 0 14.4 13.5 08/15/2005 07:50:00 1.7 0.5 3 0.4 1.2 0.7 3 0.4 0.8 0.7 3 0.4 41 17 51 255 13.7 0 14.1 13.5 08/15/2005 08:00:00 1.6 0.4 2.6 0.7 1.2 0.5 2.6 0.4 0.9 0.5 2.6 0.4 48 21 32 255 13.8 0 14.4 13.5 08/15/2005 08:10:00 1.5 0.4 2.3 0.4 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 33 13 44 255 13.9 0 14.4 13.8 08/15/2005 08:20:00 1.2 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.4 1.5 0.4 25 13 3 255 14.1 0.2 14.9 13.8 08/15/2005 08:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 6 0 6 255 14.4 0.1 14.9 14.4 08/15/2005 08:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 4 7 6 255 14.6 0.1 15.2 14.4 08/15/2005 08:50:00 0.6 0.3 1.9 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 325 9 314 255 14.6 0 15.2 14.6 08/15/2005 09:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 299 0 299 255 14.5 0 14.9 14.6 08/15/2005 09:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 299 255 14.5 0 14.9 14.4 08/15/2005 09:20:00 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 355 17 6 255 14.8 0.1 15.5 14.6 08/15/2005 09:30:00 1.2 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 342 19 6 255 15.1 0.1 15.7 15.2 08/15/2005 09:40:00 1.7 0.5 3 0.7 1.2 0.6 2.6 0.4 0.6 0.4 2.3 0.4 350 19 0 255 15.2 0.1 16 15.2 08/15/2005 09:50:00 2 0.4 3 0.7 1.5 0.6 2.6 0.4 1 0.6 2.6 0.4 352 15 357 255 15.2 0.1 15.7 15.2 08/15/2005 10:00:00 1.8 0.7 3 0.4 1.2 0.6 2.6 0.4 1.2 0.7 2.6 0.4 336 21 315 255 15 0 15.7 14.9 08/15/2005 10:10:00 1.8 0.4 2.6 0.4 1.2 0.4 1.9 0.4 0.9 0.5 2.3 0.4 348 10 338 255 15 0 15.5 14.9 08/15/2005 10:20:00 1.5 0.6 2.6 0.4 1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 339 19 343 255 15 0 15.7 15.2 08/15/2005 10:30:00 1.4 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 314 18 282 255 15.1 0 15.7 14.9 08/15/2005 10:40:00 1.6 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 315 18 301 255 15 0 15.5 14.9 08/15/2005 10:50:00 1.3 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 307 26 308 255 15 0 15.7 14.9 08/15/2005 11:00:00 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 358 23 26 255 15.3 0 15.7 15.2 08/15/2005 11:10:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 296 17 337 255 15.6 0 16.3 15.5 08/15/2005 11:20:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 297 21 308 255 15.7 0.1 16.3 15.7 08/15/2005 11:30:00 1.5 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 269 32 260 255 16.2 0.1 16.8 16 08/15/2005 11:40:00 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.1 0.4 312 36 268 255 16 0 16.3 15.7 08/15/2005 11:50:00 1.6 0.7 3.4 0.4 1.3 0.7 3.4 0.4 0.9 0.6 2.3 0.4 272 20 270 255 16.1 0 16.6 16 08/15/2005 12:00:00 1.3 0.8 3.4 0.4 1 0.7 2.6 0.4 0.8 0.6 3 0.4 264 33 282 255 16.1 0 16.6 16 08/15/2005 12:10:00 1.3 0.8 3 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 253 39 262 255 15.9 0 16.3 15.7 08/15/2005 12:20:00 1.4 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 287 28 281 255 15.9 0 16.3 15.7 08/15/2005 12:30:00 1.7 0.6 3.4 0.4 1.2 0.7 3 0.4 1 0.6 2.6 0.4 288 21 271 255 15.9 0 16.3 15.7 08/15/2005 12:40:00 2.1 0.5 3.4 0.7 1.7 0.7 3 0.4 1 0.6 2.6 0.4 308 12 294 255 16.3 0.1 16.8 16 08/15/2005 12:50:00 1.7 0.6 3 0.4 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 304 27 291 255 16.8 0 16.8 16.6 08/15/2005 13:00:00 1.8 0.8 3.4 0.4 1.4 0.9 3.4 0.4 1.1 0.8 3 0.4 305 23 295 255 16.9 0 17.4 16.8 08/15/2005 13:10:00 2.6 0.6 4.2 0.7 2.4 0.7 4.2 0.4 2 0.6 3.4 0.4 297 12 291 255 16.8 0 17.4 16.8 08/15/2005 13:20:00 2.5 0.5 3.8 1.5 2.2 0.7 3.4 0.4 1.7 0.8 3.4 0.4 281 22 290 255 17.3 0.3 18 16.8 08/15/2005 13:30:00 2.7 0.7 4.2 0.7 2.5 0.8 4.2 0.4 2.1 0.8 3.8 0.4 294 24 285 255 18.5 0.2 19.1 18 08/15/2005 13:40:00 2.2 0.9 3.8 0.4 1.9 1 3.8 0.4 1.6 1 3.8 0.4 304 20 265 255 18.9 0 19.1 18.8 08/15/2005 13:50:00 1.9 0.8 3.4 0.4 1.5 1 3.4 0.4 1.4 0.9 3.8 0.4 317 47 290 255 18.5 0.2 19.4 18 08/15/2005 14:00:00 2.4 0.5 3.8 1.1 2.2 0.6 3.8 0.4 1.8 0.6 3.4 0.4 308 10 311 255 17.8 0 18.2 17.7 08/15/2005 14:10:00 2.4 0.7 4.2 0.7 2.1 0.8 4.2 0.4 1.8 1 4.2 0.4 305 14 307 255 17.6 0 17.7 17.4 08/15/2005 14:20:00 2.2 0.6 3.8 0.7 1.9 0.7 3.8 0.4 1.5 0.8 3.8 0.4 310 19 300 255 18 0 18.2 17.7 08/15/2005 14:30:00 2.4 0.7 4.6 0.4 2.1 0.8 4.2 0.4 1.5 0.8 4.2 0.4 302 24 317 255 18.1 0 18.2 18 08/15/2005 14:40:00 2.7 0.8 4.6 0.4 2.4 1 4.6 0.4 2 1 4.2 0.4 296 23 307 255 18 0 18.2 17.7 08/15/2005 14:50:00 2.6 0.9 4.2 0.7 2.2 1 4.2 0.4 1.7 1.1 4.2 0.4 293 22 311 255 18.5 0.1 18.8 18 08/15/2005 15:00:00 2.5 0.7 4.2 0.7 2.2 0.9 4.2 0.4 1.7 0.9 4.2 0.4 273 26 302 255 18.8 0.3 19.4 18.2 08/15/2005 15:10:00 2.5 0.7 4.2 0.7 2.1 0.8 4.2 0.4 1.6 0.9 4.2 0.4 273 29 278 255 19 0.4 20 18.2 08/15/2005 15:20:00 2.5 1 4.9 0.4 2.1 1.1 4.9 0.4 1.8 1 4.6 0.4 283 33 284 255 19.3 0 19.4 19.1 08/15/2005 15:30:00 2.6 0.8 4.6 1.1 2.3 0.9 4.6 0.4 1.9 0.9 4.2 0.4 299 21 316 255 19.7 0 20.3 19.4 08/15/2005 15:40:00 2.4 0.6 3.8 1.1 2 0.7 3.8 0.4 1.6 0.8 3.8 0.4 299 26 285 255 20 0.4 20.5 19.4 08/15/2005 15:50:00 2.1 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.2 0.8 3 0.4 294 33 283 255 20.3 0.2 20.8 19.7 08/15/2005 16:00:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 122 82 261 255 20 0 20.3 19.7 08/15/2005 16:10:00 1 0.6 3 0.4 0.7 0.5 2.6 0.4 0.5 0.3 1.5 0.4 25 41 333 255 20.1 0.2 20.5 19.7 08/15/2005 16:20:00 1.3 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 298 29 291 255 20.2 0 20.5 20 08/15/2005 16:30:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.5 2.3 0.4 328 32 336 255 19.7 0.1 20 19.4 08/15/2005 16:40:00 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 15 43 319 255 19.5 0 19.7 19.4 08/15/2005 16:50:00 1.1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.5 0.3 2.3 0.4 12 39 14 255 19.5 0 20 19.4 08/15/2005 17:00:00 1.8 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1 0.5 2.6 0.4 356 12 347 255 19.6 0.1 20 19.4 08/15/2005 17:10:00 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 348 16 8 255 19.5 0.1 20 19.4 08/15/2005 17:20:00 2.1 0.4 3 0.4 1.4 0.4 2.6 0.4 1.2 0.6 2.6 0.4 339 11 338 255 19.5 0.1 20 19.4 08/15/2005 17:30:00 1.8 0.6 3.4 0.7 1.3 0.7 3.4 0.4 0.7 0.4 2.3 0.4 351 19 30 255 19.4 0 20 19.1 08/15/2005 17:40:00 2.6 0.4 3.4 1.1 2.3 0.5 3.4 0.4 1.3 0.7 3 0.4 0 13 20 255 19.1 0 19.7 18.8 08/15/2005 17:50:00 2.4 0.4 3.4 1.1 1.8 0.5 3.4 0.4 1.2 0.6 2.6 0.4 348 10 343 255 18.6 0.1 19.4 18.2 08/15/2005 18:00:00 1.9 0.4 3 1.1 1.1 0.4 1.9 0.4 1.2 0.5 2.3 0.4 336 8 326 255 18.4 0 18.8 18.2 08/15/2005 18:10:00 1.8 0.4 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 308 9 314 255 18.3 0 18.8 18.2 08/15/2005 18:20:00 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 315 28 335 255 18.3 0 18.8 18.2 08/15/2005 18:30:00 1.5 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 294 22 286 255 18.3 0 18.2 18.2 08/15/2005 18:40:00 1.4 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 284 14 293 255 18.2 0 18.2 18 08/15/2005 18:50:00 1.4 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.2 1.5 0.4 241 22 237 255 17.9 0 18.2 17.7 08/15/2005 19:00:00 1.8 0.4 2.6 0.7 1.4 0.5 2.6 0.4 0.8 0.4 1.9 0.4 243 5 235 255 17.4 0.1 17.7 16.8 08/15/2005 19:10:00 1.8 0.4 2.6 0.7 1.5 0.4 2.3 0.4 0.6 0.3 1.5 0.4 234 6 244 255 16.8 0.1 17.1 16.6 08/15/2005 19:20:00 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.5 0.2 1.5 0.4 245 39 328 255 16.2 0.1 16.8 16 08/15/2005 19:30:00 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.4 1.9 0.4 349 6 342 255 15.9 0 16.3 15.7 08/15/2005 19:40:00 0.6 0.4 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 341 0 341 255 15.7 0 16.3 15.5 08/15/2005 19:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 313 18 289 255 15.3 0.1 15.7 15.2 08/15/2005 20:00:00 1.3 0.2 1.9 0.7 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 270 13 258 255 15 0 15.5 14.9 08/15/2005 20:10:00 1.4 0.2 1.9 0.7 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 248 5 255 255 14.8 0.1 15.5 14.6 08/15/2005 20:20:00 1 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 239 0 239 255 14.6 0 15.2 14.4 08/15/2005 20:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 0 239 255 14.2 0.1 14.9 14.1 08/15/2005 20:40:00 0.8 0.5 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 204 39 175 255 13.9 0 14.6 13.8 08/15/2005 20:50:00 1 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 154 0 154 255 13.7 0.1 14.4 13.5 08/15/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 255 255 13.5 0.1 13.8 13 08/15/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 255 255 13.2 0.1 13.5 13 08/15/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 47 255 255 13.1 0.1 13.5 13 08/15/2005 21:30:00 1.1 0.6 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0 0.4 0.4 9 19 324 255 13.2 0 13.5 13 08/15/2005 21:40:00 2.1 0.3 3 1.1 1.8 0.4 2.6 0.7 0.7 0.4 1.9 0.4 294 9 293 255 13.3 0.1 13.8 13 08/15/2005 21:50:00 1.3 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 289 8 284 255 13.6 0.1 14.1 13.3 08/15/2005 22:00:00 1.2 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 330 16 298 255 13.7 0 14.4 13.5 08/15/2005 22:10:00 1.8 0.5 3 0.7 1.4 0.6 2.6 0.4 0.5 0.3 2.3 0.4 312 11 305 255 13.7 0 14.1 13.5 08/15/2005 22:20:00 2.3 0.5 3.8 0.7 2 0.6 3.4 0.4 0.9 0.6 2.6 0.4 294 11 289 255 13.7 0 14.4 13.5 08/15/2005 22:30:00 2.2 0.5 3.4 1.1 1.9 0.6 3.4 0.7 0.8 0.5 2.3 0.4 280 13 293 255 13.9 0 14.6 13.8 08/15/2005 22:40:00 2.2 0.5 3.8 1.1 2 0.6 3.4 0.4 1.1 0.6 2.6 0.4 273 14 265 255 14 0.1 14.6 13.8 08/15/2005 22:50:00 2.1 0.5 3.4 1.1 1.8 0.5 3 0.4 0.7 0.5 2.3 0.4 255 11 269 255 14.2 0.1 14.6 14.1 08/15/2005 23:00:00 1.3 0.7 2.6 0.4 1 0.7 2.6 0.4 0.5 0.3 1.5 0.4 252 8 261 255 14 0.1 14.6 13.8 08/15/2005 23:10:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 118 122 2 255 13.8 0 14.1 13.5 08/15/2005 23:20:00 1.1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.4 0.1 0.7 0.4 19 5 13 255 13.5 0 13.5 13.3 08/15/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 255 255 13.3 0 13.5 13 08/15/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 255 255 13.1 0 13.3 13 08/15/2005 23:50:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 2 22 255 12.7 0 13 12.5 08/16/2005 00:00:00 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 3 53 255 12.6 0 12.7 12.5 08/16/2005 00:10:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 75 2 77 255 12.5 0 12.5 12.5 08/16/2005 00:20:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 0 73 255 12.6 0 12.7 12.5 08/16/2005 00:30:00 1 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 73 0 73 255 12.6 0 12.7 12.5 08/16/2005 00:40:00 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 0 73 255 12.7 0 12.7 12.5 08/16/2005 00:50:00 1.1 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 0 73 255 12.8 0 12.7 12.7 08/16/2005 01:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 0 73 255 12.8 0 13 12.7 08/16/2005 01:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 0 73 255 12.9 0 13 12.7 08/16/2005 01:20:00 1.2 0.2 1.9 0.7 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 66 13 56 255 13 0 13.5 12.7 08/16/2005 01:30:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 37 3 37 255 13.1 0 13.8 13 08/16/2005 01:40:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 62 12 60 255 13.1 0.1 13.5 13 08/16/2005 01:50:00 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 64 7 60 255 12.9 0 13.3 12.7 08/16/2005 02:00:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 108 28 71 255 12.8 0 13.3 12.7 08/16/2005 02:10:00 1.2 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 144 11 155 255 12.7 0 12.7 12.7 08/16/2005 02:20:00 1.5 0.4 2.3 0.7 1 0.5 1.9 0.4 0.4 0.2 1.5 0.4 115 16 101 255 12.8 0 12.7 12.7 08/16/2005 02:30:00 1.9 0.5 3 0.7 1.6 0.6 2.6 0.4 0.7 0.5 1.9 0.4 82 10 71 255 12.5 0.1 12.7 12.5 08/16/2005 02:40:00 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 0.5 0.2 1.5 0.4 83 11 74 255 12.4 0 12.5 12.2 08/16/2005 02:50:00 1.4 0.3 2.3 0.7 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 96 10 86 255 12.3 0 12.5 12.2 08/16/2005 03:00:00 1.4 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 124 17 108 255 12.1 0 12.2 11.9 08/16/2005 03:10:00 2.2 0.4 3 0.7 2 0.5 2.6 0.4 1.8 0.6 2.6 0.4 139 7 142 255 12.1 0 12.2 11.9 08/16/2005 03:20:00 2 0.3 2.6 1.1 1.8 0.4 2.6 1.1 0.9 0.5 2.3 0.4 140 7 134 255 12.1 0 12.2 11.9 08/16/2005 03:30:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 143 0 143 255 12 0 12.2 11.9 08/16/2005 03:40:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 77 36 80 255 12 0 12.2 11.9 08/16/2005 03:50:00 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 46 0 46 255 12.1 0 12.2 11.9 08/16/2005 04:00:00 1.4 0.3 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.4 0.4 62 11 73 255 12.1 0 12.2 11.9 08/16/2005 04:10:00 1.1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 73 0 73 255 12.1 0 12.2 11.9 08/16/2005 04:20:00 1.5 0.4 2.3 0.7 1.1 0.5 2.3 0.4 0.4 0.1 0.7 0.4 59 13 43 255 12.3 0 12.5 12.2 08/16/2005 04:30:00 1.7 0.2 2.3 1.1 1.3 0.3 1.9 0.4 0.4 0.2 1.1 0.4 52 1 55 255 12.3 0 12.5 12.2 08/16/2005 04:40:00 1.2 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 52 12 49 255 12.3 0 12.5 11.9 08/16/2005 04:50:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 0.8 0.4 1.9 0.4 124 12 112 255 11.9 0.1 12.2 11.7 08/16/2005 05:00:00 1.9 0.4 2.6 0.4 1.6 0.5 2.6 0.4 0.4 0.2 1.1 0.4 107 10 121 255 12.1 0 12.2 11.9 08/16/2005 05:10:00 1.7 0.3 2.6 1.1 1.5 0.4 2.6 0.7 0.4 0.1 1.1 0.4 101 10 88 255 12 0 12.2 11.9 08/16/2005 05:20:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.5 0.9 0.5 2.3 0.4 79 9 82 255 12 0 12.2 11.9 08/16/2005 05:30:00 1.5 0.5 3 0.4 1.2 0.6 2.6 0.4 0.6 0.4 1.9 0.4 46 17 39 255 12.2 0 12.2 11.9 08/16/2005 05:40:00 1.3 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.1 0.4 36 4 40 255 12.4 0 12.5 12.2 08/16/2005 05:50:00 1.4 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.5 0.4 39 5 45 255 12.5 0 12.7 12.5 08/16/2005 06:00:00 1.2 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.4 0.2 1.5 0.4 48 22 42 255 12.7 0 12.7 12.7 08/16/2005 06:10:00 2.1 0.5 3 0.7 1.8 0.6 3.4 0.4 1 0.5 2.6 0.4 61 12 80 255 12.8 0 13 12.7 08/16/2005 06:20:00 2.1 0.6 3 0.7 1.8 0.7 3 0.4 1.5 0.7 3 0.4 34 17 62 255 13 0 13.3 12.7 08/16/2005 06:30:00 2.2 0.4 3.4 1.1 2 0.5 3.4 0.7 1.2 0.6 2.6 0.4 15 9 18 255 13.1 0 13.3 13 08/16/2005 06:40:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 0.7 1.3 0.7 3 0.4 29 17 17 255 13 0 13 12.7 08/16/2005 06:50:00 2.1 0.7 3.8 0.4 1.9 0.9 3.8 0.4 1.3 0.8 3 0.4 35 12 39 255 13 0 13 12.7 08/16/2005 07:00:00 2.1 0.5 3 0.7 1.9 0.5 3 0.4 1.3 0.7 3 0.4 33 13 22 255 13.1 0 13 13 08/16/2005 07:10:00 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 1.6 0.7 3.4 0.4 26 11 28 255 13.1 0 13 13 08/16/2005 07:20:00 2 0.5 3.8 0.7 1.7 0.6 3.8 0.4 1 0.5 3 0.4 40 14 31 255 13.1 0 13 13 08/16/2005 07:30:00 1.8 0.5 3 0.7 1.5 0.7 3 0.4 1.1 0.6 2.6 0.4 54 14 45 255 13.3 0 13.3 13 08/16/2005 07:40:00 2.5 0.5 3.8 1.5 2.3 0.5 3.4 1.1 1.8 0.6 3.4 0.4 52 12 69 255 13.4 0 13.5 13.3 08/16/2005 07:50:00 2.2 0.3 3 1.5 1.9 0.4 3.4 0.7 1.2 0.5 2.3 0.4 49 13 52 255 13.5 0 13.5 13.5 08/16/2005 08:00:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.1 2.3 0.6 3.4 0.7 30 11 19 255 13.7 0 13.8 13.5 08/16/2005 08:10:00 2.1 0.6 3.4 0.4 2 0.7 3.4 0.4 1.5 0.8 3.4 0.4 43 14 35 255 13.6 0 13.8 13.5 08/16/2005 08:20:00 1.5 0.7 3 0.4 1.2 0.7 2.6 0.4 0.9 0.6 2.3 0.4 59 10 71 255 13.7 0 14.6 13.5 08/16/2005 08:30:00 1.5 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 51 15 34 255 14 0.1 14.6 13.8 08/16/2005 08:40:00 1.6 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 40 15 48 255 14.3 0 15.2 14.1 08/16/2005 08:50:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 0.7 1.7 0.5 3 0.4 50 9 38 255 14.6 0 15.2 14.6 08/16/2005 09:00:00 2.1 0.5 3.8 1.1 1.9 0.6 3.4 0.4 1.5 0.6 3.8 0.4 43 16 51 255 14.9 0 15.5 14.9 08/16/2005 09:10:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 1.9 0.5 3 0.7 45 10 59 255 15.1 0 15.7 15.2 08/16/2005 09:20:00 1.9 0.6 3 0.4 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 40 12 35 255 15.2 0 16 15.2 08/16/2005 09:30:00 1.2 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.9 0.4 29 17 24 255 15.7 0.1 16.3 15.5 08/16/2005 09:40:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.5 0.4 10 10 10 255 16.1 0.2 16.8 16 08/16/2005 09:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 18 12 10 255 16.5 0 17.1 16.3 08/16/2005 10:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 358 27 25 255 16.9 0 17.1 16.8 08/16/2005 10:10:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 349 29 332 255 17.4 0.1 18 16.8 08/16/2005 10:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 40 17 64 255 17.8 0 18 17.7 08/16/2005 10:30:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 329 27 306 255 18.2 0 18.5 18 08/16/2005 10:40:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 326 18 335 255 18.5 0 18.8 18.2 08/16/2005 10:50:00 0.7 0.5 3 0.4 0.5 0.4 3 0.4 0.4 0.2 1.5 0.4 330 32 295 255 19.2 0.4 20.5 18.8 08/16/2005 11:00:00 1.1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 308 33 323 255 20.2 0 20.8 19.7 08/16/2005 11:10:00 1.6 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 306 21 304 255 19.3 0.1 20 19.1 08/16/2005 11:20:00 1.9 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 308 20 303 255 19.1 0.1 20 18.8 08/16/2005 11:30:00 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 1 0.6 2.6 0.4 310 14 284 255 19 0.1 19.7 18.5 08/16/2005 11:40:00 2.2 0.4 3 0.7 1.9 0.5 3 0.4 1.7 0.7 3.4 0.4 308 11 296 255 18.9 0.2 19.4 18.5 08/16/2005 11:50:00 1.8 0.4 2.6 0.7 1.4 0.5 2.6 0.4 1.3 0.4 2.3 0.4 307 8 318 255 18.7 0.1 19.1 18.5 08/16/2005 12:00:00 1.9 0.3 2.6 1.1 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 298 10 289 255 18.7 0 19.4 18.5 08/16/2005 12:10:00 1.7 0.6 3 0.4 1.4 0.6 2.6 0.4 1 0.6 2.6 0.4 296 15 311 255 19 0.2 19.7 18.5 08/16/2005 12:20:00 2.3 0.8 3.8 0.4 2 0.9 3.4 0.4 1.7 1 3.8 0.4 299 11 284 255 19.5 0 20.3 19.1 08/16/2005 12:30:00 2.4 0.5 3.8 1.1 2.1 0.5 3.4 0.4 1.6 0.7 3 0.4 299 17 297 255 19.2 0.2 20 18.8 08/16/2005 12:40:00 2.3 0.6 4.2 0.7 2 0.7 3.8 0.4 1.6 0.8 4.2 0.4 290 22 294 255 18.9 0 19.4 18.5 08/16/2005 12:50:00 2.2 0.9 4.2 0.4 1.9 1 3.8 0.4 1.5 0.9 3.4 0.4 295 22 307 255 18.9 0.1 19.4 18.5 08/16/2005 13:00:00 2.3 0.7 3.8 0.7 2 0.8 3.8 0.4 1.5 0.8 3.8 0.4 302 19 317 255 19.2 0 19.4 19.1 08/16/2005 13:10:00 3 0.7 4.9 1.5 2.8 0.8 4.9 0.4 2.1 1 4.6 0.4 303 26 308 255 19.6 0 20 19.4 08/16/2005 13:20:00 2.9 0.8 4.9 0.7 2.7 1 4.6 0.4 2.2 1 4.2 0.4 298 16 306 255 19.6 0.1 20 19.4 08/16/2005 13:30:00 2.1 0.8 4.2 0.4 1.7 1 4.2 0.4 1.2 1 3.8 0.4 291 39 287 255 19.7 0.1 20.5 19.4 08/16/2005 13:40:00 2.1 0.9 4.9 0.4 1.7 0.9 4.2 0.4 1.4 0.9 4.2 0.4 290 33 310 255 20.4 0.1 21.1 20 08/16/2005 13:50:00 2.3 1 4.9 0.4 2 1 4.6 0.4 1.7 1 4.2 0.4 274 38 294 255 21.1 0.2 21.7 20.5 08/16/2005 14:00:00 2.8 1 4.2 0.4 2.6 1 4.6 0.4 2.1 0.9 3.8 0.4 292 27 294 255 21.1 0 21.4 20.8 08/16/2005 14:10:00 2.5 0.9 4.6 0.7 2.2 1 4.6 0.4 1.7 1.1 4.2 0.4 298 35 277 255 21.6 0.4 22.3 20.8 08/16/2005 14:20:00 2.3 0.7 4.2 0.4 2 0.8 4.2 0.4 1.7 0.9 4.2 0.4 281 32 294 255 21.9 0 22.3 21.7 08/16/2005 14:30:00 2.3 0.7 4.2 0.4 2.1 0.8 4.6 0.4 1.6 0.8 3.8 0.4 277 36 243 255 22.2 0.4 23.2 21.7 08/16/2005 14:40:00 2 0.7 4.2 0.4 1.9 0.8 4.2 0.4 1.4 0.7 3.8 0.4 232 39 177 255 23 0.1 23.5 22.9 08/16/2005 14:50:00 2.6 1 4.6 0.4 2.4 1 4.6 0.4 1.7 1.1 4.6 0.4 274 35 304 255 22.7 0.4 23.5 21.7 08/16/2005 15:00:00 2.5 0.7 5.3 0.7 2.3 0.8 4.6 0.7 1.9 0.8 4.6 0.4 271 26 290 255 21.9 0.3 22.3 21.1 08/16/2005 15:10:00 3 1 5.7 1.1 2.8 1 5.7 0.7 2.2 1 5.3 0.4 279 26 249 255 21.6 0.3 22.3 21.1 08/16/2005 15:20:00 2.6 0.9 4.9 0.4 2.4 1 4.9 0.4 1.9 0.8 4.6 0.4 290 20 281 255 21.2 0.3 22 20.8 08/16/2005 15:30:00 2.6 0.6 4.6 1.1 2.5 0.7 4.2 0.7 1.8 0.9 3.8 0.4 301 18 281 255 20.6 0 21.1 20.5 08/16/2005 15:40:00 2.8 0.7 4.6 1.1 2.6 0.7 4.6 0.7 1.9 0.9 3.8 0.4 300 18 319 255 20.5 0 21.1 20.5 08/16/2005 15:50:00 2.2 0.8 4.2 0.4 1.9 0.9 3.8 0.4 1.4 1 4.2 0.4 298 24 308 255 20.9 0 21.1 20.5 08/16/2005 16:00:00 2.4 0.9 4.6 0.4 2.1 0.9 4.2 0.4 1.6 0.9 4.2 0.4 298 29 254 255 21.2 0.1 21.7 20.8 08/16/2005 16:10:00 2.8 0.7 4.6 0.7 2.6 0.8 4.6 0.4 2 1 4.6 0.4 313 20 315 255 21.9 0 22.3 21.4 08/16/2005 16:20:00 2.4 0.9 4.6 0.4 2.1 1 4.6 0.4 1.4 1 4.2 0.4 299 28 328 255 22.1 0 22.6 22 08/16/2005 16:30:00 2.1 0.8 3.8 0.4 1.9 0.8 3.4 0.4 1.4 0.8 3.8 0.4 266 29 266 255 21.6 0 22.3 21.4 08/16/2005 16:40:00 1.5 0.8 3.8 0.4 1.1 0.7 3.4 0.4 0.8 0.6 3.4 0.4 266 36 321 255 21.4 0 22 21.1 08/16/2005 16:50:00 2.1 0.8 4.6 0.4 1.8 1 4.2 0.4 1.4 0.8 3 0.4 280 24 280 255 20.9 0 21.4 20.8 08/16/2005 17:00:00 1.5 0.8 3.4 0.4 1.2 0.7 3.4 0.4 0.9 0.7 3 0.4 270 26 272 255 20.9 0 21.1 20.8 08/16/2005 17:10:00 2.5 0.8 4.6 0.7 2.2 0.8 3.8 0.4 1.7 1 3.8 0.4 279 23 293 255 20.6 0 21.1 20.5 08/16/2005 17:20:00 2.6 0.8 4.6 0.4 2.4 0.9 4.6 0.4 1.7 0.8 3.8 0.4 272 27 270 255 20.3 0.1 20.8 20.3 08/16/2005 17:30:00 2.3 0.7 4.2 0.7 1.9 1 4.2 0.4 1.3 0.9 3.4 0.4 284 22 327 255 20.1 0 20.8 20 08/16/2005 17:40:00 1.5 0.8 3.4 0.4 1.2 0.9 3.4 0.4 0.8 0.6 2.6 0.4 287 24 272 255 20.1 0.1 20.5 20 08/16/2005 17:50:00 2.5 1.2 4.2 0.4 2.4 1.2 4.2 0.4 1.7 1.1 4.9 0.4 278 21 261 255 20.1 0 20.5 20 08/16/2005 18:00:00 2.7 0.6 3.8 1.1 2.5 0.7 3.8 0.7 2 0.7 3.4 0.4 283 16 281 255 19.9 0.1 20.5 19.7 08/16/2005 18:10:00 2.8 0.6 4.2 1.1 2.6 0.8 4.2 0.4 1.8 0.9 3.8 0.4 271 17 279 255 19.7 0 20.3 19.4 08/16/2005 18:20:00 1.9 0.8 3.8 0.4 1.6 0.8 3.4 0.4 0.8 0.6 2.6 0.4 275 22 262 255 19.5 0 20 19.4 08/16/2005 18:30:00 1.5 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 281 16 283 255 19.4 0 20 19.4 08/16/2005 18:40:00 1.2 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.5 0.4 1.9 0.4 275 13 292 255 19.3 0 19.7 19.1 08/16/2005 18:50:00 1.1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 278 16 278 255 19.4 0 19.4 19.1 08/16/2005 19:00:00 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 0.7 0.4 1.9 0.4 272 18 276 255 19 0 19.4 18.8 08/16/2005 19:10:00 1.5 0.5 2.6 0.4 1 0.5 2.6 0.4 0.6 0.4 1.9 0.4 282 12 280 255 18.7 0 18.8 18.5 08/16/2005 19:20:00 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 277 18 275 255 18.5 0 18.8 18.2 08/16/2005 19:30:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 278 10 266 255 18.3 0 18.5 18.2 08/16/2005 19:40:00 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.1 1.1 0.4 276 9 269 255 18.1 0 18.2 18 08/16/2005 19:50:00 0.8 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 286 6 274 255 17.8 0 18 17.7 08/16/2005 20:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 280 0 280 255 17.5 0.1 17.7 17.1 08/16/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 255 255 17.1 0 17.4 16.8 08/16/2005 20:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 26 345 255 16.6 0.1 16.8 16.3 08/16/2005 20:30:00 1.3 0.3 1.9 0.7 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 357 15 16 255 16.1 0 16.8 15.7 08/16/2005 20:40:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 25 8 20 255 15.6 0.1 16.3 15.5 08/16/2005 20:50:00 2 0.6 3 0.7 1.6 0.8 3 0.4 0.9 0.6 2.6 0.4 41 10 37 255 15.1 0.1 15.7 15.2 08/16/2005 21:00:00 1.9 0.4 2.6 1.1 1.5 0.5 2.6 0.4 0.8 0.5 2.3 0.4 38 10 16 255 15 0 15.5 14.9 08/16/2005 21:10:00 1.6 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.5 0.3 1.9 0.4 30 11 35 255 14.8 0.2 15.5 14.6 08/16/2005 21:20:00 1.6 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.5 0.4 1.9 0.4 31 9 27 255 14.6 0.1 15.2 14.4 08/16/2005 21:30:00 1.5 0.3 2.3 0.7 1.2 0.4 2.3 0.4 0.6 0.4 1.9 0.4 47 9 53 255 14.1 0.1 14.6 13.8 08/16/2005 21:40:00 2 0.3 3 1.1 1.7 0.4 2.6 1.1 0.9 0.4 1.9 0.4 56 9 57 255 13.6 0.1 14.4 13.3 08/16/2005 21:50:00 2 0.4 3 0.7 1.8 0.5 2.6 0.4 0.9 0.5 1.9 0.4 60 12 66 255 13.2 0.2 13.8 12.7 08/16/2005 22:00:00 2.1 0.5 3.4 0.7 1.8 0.6 3.4 0.4 1 0.6 3.4 0.4 56 16 61 255 12.9 0 13.5 12.7 08/16/2005 22:10:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 0.7 1.7 0.6 3 0.4 46 10 51 255 13.1 0 13.3 12.7 08/16/2005 22:20:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1 0.6 2.3 0.4 52 15 30 255 13.3 0 13.5 13 08/16/2005 22:30:00 2 0.4 3 1.1 1.8 0.5 2.6 0.4 0.8 0.5 2.3 0.4 61 15 28 255 12.9 0.1 13.5 12.7 08/16/2005 22:40:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.3 0.6 3 0.4 56 14 41 255 12.8 0 13.3 12.7 08/16/2005 22:50:00 2.7 0.5 4.2 1.5 2.6 0.6 4.6 1.1 1.5 0.7 3 0.4 56 12 62 255 13 0.1 13.5 12.7 08/16/2005 23:00:00 2.7 0.6 4.6 1.1 2.6 0.8 4.9 0.4 1.5 0.7 3.4 0.4 52 13 60 255 13.1 0.1 13.5 13 08/16/2005 23:10:00 2.5 0.4 3.8 1.5 2.4 0.5 4.2 1.5 1.3 0.6 2.6 0.4 59 15 64 255 12.9 0 13.5 12.7 08/16/2005 23:20:00 3.1 0.7 4.9 1.5 2.9 0.8 4.9 1.1 1.8 0.7 4.2 0.4 57 16 40 255 12.8 0 13.3 12.7 08/16/2005 23:30:00 3.4 0.9 5.3 1.1 3.3 1 6.1 0.7 2.1 1 4.6 0.4 51 15 51 255 12.9 0 13.3 12.7 08/16/2005 23:40:00 3.4 0.6 4.9 1.5 3.3 0.6 4.9 1.5 2.4 0.8 4.2 0.4 47 12 37 255 13.3 0 13.3 13.3 08/16/2005 23:50:00 3.3 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.1 0.8 3.8 0.4 54 13 47 255 13.3 0 13.3 13 08/17/2005 00:00:00 3.2 0.7 4.9 1.5 3.1 0.7 5.3 1.5 2.1 0.8 4.2 0.4 60 17 65 255 12.9 0 13.3 12.7 08/17/2005 00:10:00 3.7 0.8 5.7 1.9 3.5 0.8 5.7 1.5 2.3 1 4.6 0.4 55 15 29 255 13 0.1 13.5 12.7 08/17/2005 00:20:00 3.7 0.6 6.1 2.3 3.7 0.6 5.3 2.3 2.6 0.8 5.7 0.4 49 13 49 255 13 0 13.5 12.7 08/17/2005 00:30:00 3.2 0.6 4.9 1.9 3.1 0.6 5.3 1.5 2.1 0.6 3.8 0.4 50 14 66 255 12.9 0 13.3 12.7 08/17/2005 00:40:00 3.1 0.7 4.9 1.5 3 0.6 4.6 1.5 2 0.5 3.4 0.4 48 13 21 255 12.8 0 13 12.7 08/17/2005 00:50:00 3.2 0.8 4.9 1.5 3.1 0.8 4.9 1.1 1.9 0.8 3.4 0.4 56 12 43 255 12.9 0 13.3 12.7 08/17/2005 01:00:00 4 0.7 6.1 1.9 4 0.7 6.1 2.3 2.8 0.8 5.7 0.7 55 12 55 255 12.9 0 13.5 12.7 08/17/2005 01:10:00 3.9 0.8 6.8 1.9 3.9 0.8 6.8 1.9 2.6 0.9 4.9 0.4 51 17 60 255 13.2 0 13.8 13 08/17/2005 01:20:00 3.8 0.7 5.7 1.5 3.7 0.8 6.1 1.5 2.6 1 4.9 0.4 52 15 63 255 13.6 0 14.4 13.3 08/17/2005 01:30:00 3.7 0.6 5.3 2.3 3.6 0.6 5.7 2.3 2.7 0.8 4.9 0.7 44 13 42 255 13.8 0 14.4 13.8 08/17/2005 01:40:00 3.2 0.5 4.6 1.9 3.2 0.5 4.6 1.5 2.3 0.6 4.2 0.7 40 10 40 255 13.7 0 14.1 13.5 08/17/2005 01:50:00 3.2 0.7 4.6 1.5 3.1 0.8 4.9 1.5 1.8 0.8 3.8 0.4 49 13 70 255 13.5 0 13.8 13.3 08/17/2005 02:00:00 2.7 0.6 4.6 1.1 2.6 0.6 4.6 1.5 1.6 0.6 3.4 0.4 44 15 34 255 13.3 0 13.8 13 08/17/2005 02:10:00 2.1 0.5 3.4 0.7 1.8 0.5 3 0.7 0.9 0.5 2.3 0.4 45 15 51 255 12.5 0.2 13.3 11.9 08/17/2005 02:20:00 2.3 0.4 3.4 1.1 2.1 0.4 3 0.7 1 0.5 2.3 0.4 63 15 48 255 11.7 0 12.5 11.7 08/17/2005 02:30:00 3 0.7 4.6 1.5 2.9 0.8 4.6 0.7 1.7 0.8 3.8 0.4 58 12 51 255 11.6 0 11.7 11.7 08/17/2005 02:40:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.1 1.7 0.6 3.4 0.4 54 14 45 255 11.9 0 12.2 11.7 08/17/2005 02:50:00 2.5 0.5 4.2 1.1 2.4 0.5 3.8 1.5 1.4 0.6 3 0.4 73 9 62 255 12 0 12.2 11.9 08/17/2005 03:00:00 2.4 0.4 3.8 1.5 2.4 0.4 3.8 1.1 1.2 0.6 2.6 0.4 84 10 89 255 11.7 0 11.9 11.4 08/17/2005 03:10:00 3.4 0.5 4.9 2.3 3.4 0.5 4.9 2.3 2.4 0.6 3.8 0.7 78 9 90 255 11.5 0 11.7 11.4 08/17/2005 03:20:00 3.8 0.6 5.7 2.3 3.8 0.6 5.7 2.6 2.6 0.7 4.6 1.1 67 10 50 255 11.6 0 11.9 11.4 08/17/2005 03:30:00 3.9 0.6 5.7 2.6 4 0.5 5.7 2.6 2.6 0.6 4.6 0.7 73 11 69 255 12 0 12.2 11.9 08/17/2005 03:40:00 3.8 0.6 5.7 2.6 3.9 0.6 6.1 2.6 2.6 0.7 4.6 1.1 65 12 90 255 12.3 0 12.5 11.9 08/17/2005 03:50:00 3.6 0.6 4.9 1.9 3.7 0.6 5.3 2.3 2.6 0.7 4.2 0.4 61 11 76 255 12.7 0.1 13 12.5 08/17/2005 04:00:00 3.5 0.6 4.9 1.9 3.5 0.6 4.9 1.9 2.3 0.7 3.8 0.4 65 11 71 255 13 0 13 12.7 08/17/2005 04:10:00 3.7 0.8 6.5 1.5 3.7 0.9 6.5 1.5 2.7 0.9 5.7 0.7 60 16 44 255 13.1 0 13.3 13 08/17/2005 04:20:00 2.9 0.8 4.9 1.1 3 0.8 5.3 1.1 2 0.9 4.6 0.4 57 15 40 255 13.3 0 13.3 13 08/17/2005 04:30:00 2.7 0.7 4.9 1.1 2.7 0.7 5.7 1.1 1.5 0.7 3.4 0.4 78 15 70 255 12.9 0.1 13.3 12.7 08/17/2005 04:40:00 4.6 0.8 6.5 2.3 4.7 0.7 6.1 2.6 3.3 0.9 5.3 1.1 93 12 84 255 12.8 0 13 12.7 08/17/2005 04:50:00 4 1 6.5 1.5 4.1 0.9 6.1 1.5 2.8 1.1 5.7 0.4 90 13 68 255 13.3 0 13.3 13 08/17/2005 05:00:00 3.8 0.8 6.1 1.5 3.9 0.8 6.1 1.9 2.5 1 5.3 0.4 80 14 62 255 13.3 0 13.3 13.3 08/17/2005 05:10:00 4.7 0.8 6.8 2.3 4.7 0.9 6.8 2.3 3.2 1 5.7 0.4 73 14 92 255 13.4 0 13.5 13.3 08/17/2005 05:20:00 4.5 0.8 7.2 1.9 4.6 0.8 7.6 1.9 3.6 0.9 5.7 0.7 64 13 62 255 13.7 0 13.8 13.5 08/17/2005 05:30:00 4.7 0.9 7.2 2.3 4.7 0.9 6.8 2.6 3.4 1 6.1 1.1 53 12 52 255 13.8 0 13.8 13.5 08/17/2005 05:40:00 4.6 0.8 6.1 2.3 4.6 0.8 6.8 2.6 3.2 1 5.7 0.4 56 15 50 255 13.9 0 13.8 13.5 08/17/2005 05:50:00 4.2 0.9 6.1 1.9 4.3 0.8 6.1 2.3 3.2 1 5.7 0.7 60 13 43 255 13.7 0 13.8 13.5 08/17/2005 06:00:00 4.5 0.6 6.5 3 4.5 0.6 6.5 3 3.2 0.7 4.9 1.5 63 12 70 255 13.6 0 13.5 13.5 08/17/2005 06:10:00 3.5 0.6 5.3 1.9 3.6 0.6 5.3 1.9 2.4 0.8 4.2 0.4 77 12 79 255 13.5 0 13.5 13.5 08/17/2005 06:20:00 3.3 0.6 5.3 1.9 3.3 0.6 4.9 2.3 2.3 0.7 3.8 0.4 89 12 74 255 13.8 0 14.4 13.5 08/17/2005 06:30:00 3 0.9 5.3 1.1 3.1 0.8 5.3 1.5 1.9 1 4.6 0.4 83 15 71 255 14.1 0.1 14.6 13.8 08/17/2005 06:40:00 3.7 0.8 6.1 2.3 3.7 0.8 5.7 2.3 2.8 0.9 5.3 0.4 65 12 61 255 14.2 0 14.9 14.4 08/17/2005 06:50:00 4.3 0.9 6.5 2.3 4.4 0.9 6.5 2.3 3.5 1 6.1 1.5 52 15 62 255 14.4 0 15.2 14.4 08/17/2005 07:00:00 3.8 1 6.5 1.5 3.9 0.9 6.8 1.9 2.9 1 5.7 0.7 52 16 38 255 14.6 0.1 15.2 14.6 08/17/2005 07:10:00 4.3 1.1 7.2 2.3 4.4 1.1 7.2 2.3 3.2 1 6.8 1.1 51 17 38 255 14.6 0 15.2 14.6 08/17/2005 07:20:00 4.2 0.9 6.8 2.6 4.2 0.9 6.5 2.3 3 0.9 5.3 1.1 55 15 48 255 14.8 0 15.5 14.9 08/17/2005 07:30:00 3.9 0.8 6.1 1.9 3.9 0.8 5.7 1.9 2.7 1 4.6 0.4 78 16 78 255 15 0 15.2 14.9 08/17/2005 07:40:00 5 1.1 8.8 2.3 5.1 1.1 8.4 2.6 3.8 1.1 7.2 1.1 74 15 71 255 15 0 15.5 14.9 08/17/2005 07:50:00 5.1 1.1 8.4 3 5.2 1 8.8 2.6 3.9 1 6.8 1.1 76 15 78 255 15 0 15.5 15.2 08/17/2005 08:00:00 3.8 1 6.5 1.5 4 1 6.8 1.9 2.9 1.1 6.1 0.4 70 15 58 255 15 0 15.5 15.2 08/17/2005 08:10:00 3.5 0.8 5.7 1.5 3.6 0.7 5.7 1.5 2.6 0.9 4.9 0.4 87 17 64 255 15 0 15.5 15.2 08/17/2005 08:20:00 4.3 0.7 6.1 2.3 4.3 0.7 6.5 2.6 3.2 1 5.7 0.7 86 14 88 255 15 0 15.5 14.9 08/17/2005 08:30:00 3.8 0.8 6.5 1.5 3.9 0.7 6.1 1.9 2.9 0.8 5.3 1.1 85 12 95 255 15 0 15.5 15.2 08/17/2005 08:40:00 4.2 1 6.8 1.1 4.3 0.8 6.5 2.3 3.2 1.1 5.7 0.4 81 14 87 255 15 0 15.7 15.2 08/17/2005 08:50:00 3.9 1 6.8 1.5 4 0.9 6.5 1.9 2.9 0.9 5.3 1.1 78 15 104 255 15.4 0 15.7 15.2 08/17/2005 09:00:00 3.9 1.2 6.8 1.1 4.1 1.1 7.6 1.9 3.2 1.1 6.1 0.4 80 19 89 255 15.6 0 16 15.7 08/17/2005 09:10:00 3.7 1 6.1 1.9 3.9 0.9 6.1 1.9 3 1 5.3 0.7 77 16 84 255 15.7 0 16.3 15.7 08/17/2005 09:20:00 4.4 1.2 8 2.3 4.5 1.2 8 2.3 3.5 1.2 7.2 1.1 61 17 56 255 15.9 0 16.6 15.7 08/17/2005 09:30:00 4.4 1 8 1.9 4.5 1 7.6 2.3 3.5 1.1 6.1 0.4 57 15 48 255 16 0 16.3 16 08/17/2005 09:40:00 4 1.3 6.8 1.1 4.2 1.2 7.2 1.5 3.3 1.3 6.1 0.7 62 17 55 255 16 0 16.3 16 08/17/2005 09:50:00 4.3 1.2 7.2 1.1 4.4 1.1 6.8 1.9 3.3 1.2 6.1 0.4 76 18 82 255 16 0 16.3 16 08/17/2005 10:00:00 4.2 1.4 7.2 1.1 4.4 1.3 7.2 1.9 3.5 1.3 6.8 0.7 69 17 80 255 16.1 0 16.8 16 08/17/2005 10:10:00 4.4 1.3 8 1.5 4.5 1.3 8 1.9 3.4 1.3 6.5 0.4 68 18 46 255 16.2 0.1 16.8 16.3 08/17/2005 10:20:00 4.8 1.2 8.4 1.5 4.9 1.1 8.4 2.3 4.1 1.2 8 1.9 61 17 83 255 16.5 0 16.8 16.3 08/17/2005 10:30:00 5.4 1.4 9.9 3 5.5 1.3 9.9 2.6 4.5 1.3 9.1 1.5 61 17 60 255 16.7 0 17.1 16.6 08/17/2005 10:40:00 4.8 1.1 7.6 1.5 4.8 1 7.2 2.3 4.1 1 7.2 1.9 55 15 40 255 16.8 0.1 17.1 16.8 08/17/2005 10:50:00 6.9 1.7 10.3 2.6 6.8 1.7 10.3 3 5.9 1.6 10.3 2.6 39 15 16 255 17 0.1 17.4 16.8 08/17/2005 11:00:00 6.5 1.2 9.9 3.8 6.5 1.2 9.9 4.2 5.4 1.3 9.1 2.6 35 12 28 255 17.3 0.1 17.7 17.1 08/17/2005 11:10:00 3.9 1.2 7.6 1.9 4 1.2 7.2 2.3 3.4 1.3 6.8 0.4 33 14 28 255 17.5 0.1 17.7 17.4 08/17/2005 11:20:00 4.6 1.2 7.6 1.9 4.7 1.2 8 1.9 3.5 1.3 6.5 0.4 46 18 42 255 17.5 0 18 17.4 08/17/2005 11:30:00 5.9 1.3 9.5 3 5.9 1.2 9.5 3 4.7 1.3 8.8 1.9 57 17 54 255 17.6 0 18 17.4 08/17/2005 11:40:00 4.9 1.1 8.4 2.6 5 1 8.4 2.6 4.2 1.2 7.6 1.5 53 17 44 255 17.8 0 18.2 17.4 08/17/2005 11:50:00 6.7 1.4 10.7 3.4 6.6 1.3 11.1 3.4 5.5 1.4 8.8 1.9 36 17 36 255 17.8 0 18.2 17.7 08/17/2005 12:00:00 6.4 1.2 9.9 3.4 6.4 1.2 9.5 3.4 5.5 1.2 9.5 3 36 15 40 255 18 0 18.2 17.7 08/17/2005 12:10:00 5 1.1 7.6 1.5 5 1 7.6 1.9 4.1 1.2 7.2 1.1 30 15 40 255 18.2 0 18.8 18 08/17/2005 12:20:00 4.9 1 7.6 2.3 4.9 1 7.6 2.6 4.1 1.1 7.2 1.9 41 15 58 255 18.3 0 18.8 18 08/17/2005 12:30:00 4.1 1 6.1 1.5 4.2 1 6.8 1.9 3.3 1.1 6.1 0.4 47 19 35 255 18.3 0 18.8 18.2 08/17/2005 12:40:00 4.7 1.2 7.2 1.1 4.7 1.1 7.2 1.5 3.6 1.1 6.5 1.1 30 17 17 255 18.4 0.1 18.8 18.2 08/17/2005 12:50:00 4.1 1 6.8 1.1 4.2 1.1 7.2 1.1 2.9 1.1 6.1 0.4 13 17 20 255 18.6 0.1 19.1 18.2 08/17/2005 13:00:00 3.7 0.9 6.5 1.9 3.7 0.9 6.8 1.5 2.7 1.1 5.3 0.4 14 17 15 255 18.6 0 19.1 18.5 08/17/2005 13:10:00 5.2 1.2 8.8 2.3 5.3 1.1 8.8 2.6 4 1.3 8 0.7 24 18 8 255 18.5 0.1 18.8 18.5 08/17/2005 13:20:00 8 1.3 12.6 5.3 8 1.4 12.6 4.9 6.4 1.6 11.1 2.6 18 13 11 255 18.4 0 18.8 18.2 08/17/2005 13:30:00 7.8 1.3 11.1 4.2 7.7 1.3 11.1 3.8 6.4 1.7 11.1 2.3 24 14 19 255 18.4 0 18.5 18.2 08/17/2005 13:40:00 6.3 0.9 8.8 4.6 6.3 0.9 8.8 4.2 5.3 1 8 3 36 12 37 255 18.2 0 18.5 17.7 08/17/2005 13:50:00 4.1 0.6 5.7 1.9 4.2 0.6 5.7 2.3 3.3 0.8 4.9 1.5 30 13 42 255 17.3 0.2 18 16.8 08/17/2005 14:00:00 3.3 0.5 4.6 1.9 3.4 0.5 4.6 2.3 2.5 0.6 4.2 1.1 27 10 30 255 16.7 0 17.1 16.6 08/17/2005 14:10:00 2.5 0.6 4.2 0.4 2.5 0.5 4.2 0.4 1.9 0.7 4.2 0.4 27 12 27 255 16.4 0 16.8 16.3 08/17/2005 14:20:00 2.3 0.5 3.8 0.4 2.4 0.5 3.8 0.7 1.5 0.6 2.6 0.4 64 18 77 255 16.1 0 16.6 16 08/17/2005 14:30:00 3 0.9 5.7 0.7 3.1 0.9 6.1 1.5 2 1 4.9 0.4 71 18 87 255 15.8 0 16.3 15.7 08/17/2005 14:40:00 3.8 0.8 6.1 1.5 3.9 0.8 6.1 1.9 2.9 1 5.7 0.7 58 15 48 255 15.6 0 16 15.7 08/17/2005 14:50:00 3.5 0.8 5.7 1.1 3.5 0.8 5.3 1.5 2.7 0.7 4.2 0.7 92 21 65 255 15.6 0 16.3 15.7 08/17/2005 15:00:00 3.3 0.9 5.7 0.7 3.4 0.8 5.7 1.1 2.6 0.9 4.6 0.4 83 19 68 255 15.7 0.1 16.3 15.7 08/17/2005 15:10:00 3.7 1 6.1 1.1 3.8 1 6.5 1.5 2.6 0.9 5.3 0.4 73 16 55 255 15.9 0 16.6 15.7 08/17/2005 15:20:00 4 0.9 5.7 1.9 4.1 0.9 6.1 1.9 3.1 1 5.3 0.7 73 17 87 255 15.9 0 16.6 16 08/17/2005 15:30:00 3.7 1 6.1 1.5 3.8 0.9 6.1 1.9 2.7 0.9 5.3 0.4 70 15 53 255 15.9 0 16.6 15.7 08/17/2005 15:40:00 4 0.8 6.5 1.9 4.1 0.8 6.5 1.9 3.2 0.9 4.9 0.7 72 17 59 255 15.9 0 16.6 15.7 08/17/2005 15:50:00 3.6 0.8 5.7 1.1 3.7 0.7 5.7 1.9 2.8 0.8 4.9 1.5 65 13 74 255 16 0 16.6 16 08/17/2005 16:00:00 3.5 0.7 5.3 1.5 3.6 0.7 5.3 2.3 2.5 0.8 4.6 0.7 51 17 40 255 16 0 16.6 16 08/17/2005 16:10:00 3.4 0.6 5.3 1.9 3.4 0.6 5.3 1.5 2.7 0.7 4.6 0.7 42 13 55 255 16.1 0 16.6 16 08/17/2005 16:20:00 2.8 0.7 4.6 0.7 2.9 0.6 4.6 1.1 2.1 0.8 4.2 0.4 40 15 24 255 16.2 0.1 16.8 16.3 08/17/2005 16:30:00 2.2 0.5 3.4 0.7 2.3 0.5 3.4 1.1 1.3 0.6 2.3 0.4 55 11 40 255 16.4 0.1 16.8 16.3 08/17/2005 16:40:00 3 1.2 6.1 0.7 3.2 1.2 6.5 0.7 2.2 1.2 4.9 0.4 48 22 73 255 16.2 0.1 16.8 16.3 08/17/2005 16:50:00 3.8 1.1 6.8 1.1 3.9 1 6.8 1.1 2.8 1.2 5.7 0.4 33 21 39 255 16.4 0.1 16.8 16.3 08/17/2005 17:00:00 3.3 1.3 6.1 0.7 3.4 1.2 6.5 1.5 2.2 1.2 6.1 0.4 32 27 40 255 16.4 0.2 16.8 16.3 08/17/2005 17:10:00 4.3 1.5 8.4 0.7 4.4 1.4 8.4 1.5 3.5 1.6 8 0.4 34 17 7 255 16.3 0.1 16.8 16.3 08/17/2005 17:20:00 5.6 1.2 8.4 3 5.6 1.2 8.4 2.6 4.4 1.5 8 1.1 21 17 92 255 16.4 0.1 16.8 16.3 08/17/2005 17:30:00 6 1.3 10.7 3 6 1.3 10.7 3 4.7 1.3 9.1 1.5 22 14 37 255 16.2 0.1 16.8 16.3 08/17/2005 17:40:00 6.5 1.2 9.9 3 6.5 1.1 9.5 3.8 4.8 1.5 8.4 1.5 17 11 31 255 16.1 0 16.8 16 08/17/2005 17:50:00 5.4 1.1 8.8 2.6 5.5 1.1 8.8 2.3 3.8 1.3 6.8 0.7 12 16 27 255 15.7 0 16.3 15.5 08/17/2005 18:00:00 5.6 1.1 8.8 2.3 5.6 1.1 9.1 2.3 4.1 1.3 7.6 0.4 15 14 11 255 15.3 0 16 15.5 08/17/2005 18:10:00 5.1 1.3 8.8 2.3 5.2 1.2 8.4 2.3 3.6 1.2 7.2 1.1 8 13 21 255 15.2 0 15.7 15.2 08/17/2005 18:20:00 4.1 1.5 8.8 0.7 4.3 1.4 8.8 1.9 2.6 1.2 6.5 0.4 5 22 338 255 15.1 0 15.7 15.2 08/17/2005 18:30:00 3.7 1.3 8 0.4 3.9 1.2 8 0.7 2.5 1.3 6.8 0.4 358 16 346 255 15 0 15.7 15.2 08/17/2005 18:40:00 2.5 1.1 6.1 0.4 2.6 1 6.5 0.4 1.4 1 4.9 0.4 356 18 351 255 15 0 15.7 15.2 08/17/2005 18:50:00 2.8 1 5.3 0.4 2.8 1 5.7 0.4 1.9 1 5.3 0.4 20 22 24 255 15 0 15.7 14.9 08/17/2005 19:00:00 3.6 0.9 6.5 1.1 3.7 0.9 6.5 1.1 2.7 1.1 4.9 0.4 22 20 33 255 14.9 0 15.5 14.9 08/17/2005 19:10:00 5.3 1.1 8.4 3 5.3 1 8.4 3 4.4 1.1 8 1.9 37 14 49 255 14.9 0 15.2 14.9 08/17/2005 19:20:00 5.6 1 8 3 5.6 1 7.6 2.6 4.7 1.1 7.2 1.9 42 11 44 255 14.6 0 15.2 14.4 08/17/2005 19:30:00 6.3 1.2 9.9 3.4 6.3 1.2 9.9 3.4 5.2 1.2 8 2.3 31 13 39 255 14.4 0 14.9 14.4 08/17/2005 19:40:00 4.2 1.7 8 0.4 4.5 1.5 8 1.1 3.4 1.4 7.2 0.4 52 23 28 255 14.4 0 14.9 14.4 08/17/2005 19:50:00 4.2 1.3 8.4 1.1 4.5 1.2 8.8 1.9 3.4 1.4 8.4 0.4 65 19 11 255 14.1 0.1 14.6 13.8 08/17/2005 20:00:00 4 1 6.5 1.1 4.3 1 7.2 1.9 3.2 1 6.1 0.7 75 13 62 255 13.8 0 14.1 13.5 08/17/2005 20:10:00 4.2 0.7 6.8 2.3 4.3 0.7 6.8 2.3 3.2 0.8 5.3 1.1 80 12 53 255 13.5 0 14.1 13.3 08/17/2005 20:20:00 4 0.8 5.7 1.1 4 0.7 5.3 1.9 2.9 0.7 5.3 1.1 80 15 77 255 13.4 0 13.8 13.3 08/17/2005 20:30:00 3.3 0.6 4.9 1.5 3.5 0.5 4.9 1.9 2.4 0.6 3.8 0.7 85 11 76 255 13.3 0 13.3 13.3 08/17/2005 20:40:00 3.6 0.7 5.3 2.3 3.8 0.6 5.3 2.3 2.5 0.8 4.6 0.4 81 11 71 255 13.1 0 13.3 13 08/17/2005 20:50:00 1.8 0.6 3.8 0.4 2 0.5 3.8 1.1 0.9 0.6 3 0.4 69 14 70 255 12.9 0 13 12.7 08/17/2005 21:00:00 1.7 0.6 3 0.4 1.8 0.6 3.4 0.7 0.9 0.6 2.6 0.4 65 18 83 255 12.8 0 12.7 12.7 08/17/2005 21:10:00 1.7 0.5 3 0.7 1.8 0.5 2.6 0.7 0.7 0.4 1.9 0.4 71 18 91 255 12.7 0 12.7 12.5 08/17/2005 21:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 55 22 68 255 12.5 0 12.7 12.5 08/17/2005 21:30:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 0.6 0.4 1.9 0.4 76 7 84 255 12.3 0 12.5 12.2 08/17/2005 21:40:00 2.2 0.8 4.2 0.4 2.2 0.8 3.8 0.4 1.2 0.8 3.4 0.4 103 15 109 255 12.3 0 12.5 12.2 08/17/2005 21:50:00 1.8 0.9 3.8 0.4 1.9 0.8 3.8 0.4 0.8 0.6 3.4 0.4 111 22 103 255 12.4 0 12.5 12.2 08/17/2005 22:00:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 0.8 0.5 1.9 0.4 115 13 122 255 12.3 0 12.5 12.2 08/17/2005 22:10:00 2.8 0.7 4.6 0.4 2.9 0.7 4.6 0.7 1.8 0.7 3.4 0.4 119 12 127 255 12.3 0 12.5 12.2 08/17/2005 22:20:00 3.5 0.5 4.6 1.9 3.6 0.5 4.6 1.9 2.4 0.5 3.4 1.1 117 11 127 255 12.5 0 12.7 12.2 08/17/2005 22:30:00 3 0.7 4.6 0.7 3 0.7 4.2 1.5 2.1 0.6 3.8 0.7 120 12 122 255 12.7 0 12.7 12.5 08/17/2005 22:40:00 3.2 0.7 4.9 1.1 3.4 0.6 4.9 1.9 2 0.8 3.8 0.4 115 12 131 255 12.7 0 12.7 12.7 08/17/2005 22:50:00 3 0.6 4.6 1.5 3.2 0.6 4.2 1.5 2.1 0.6 3.4 0.7 113 9 112 255 12.7 0 12.7 12.7 08/17/2005 23:00:00 2.6 0.6 3.8 1.1 2.9 0.5 4.2 1.9 1.5 0.7 3.4 0.4 108 11 103 255 12.7 0 12.7 12.7 08/17/2005 23:10:00 1.9 0.7 3.4 0.4 2 0.7 3.8 0.4 0.7 0.5 2.3 0.4 106 17 110 255 12.6 0 12.7 12.5 08/17/2005 23:20:00 0.9 0.7 3 0.4 1.1 0.7 2.6 0.4 0.4 0.2 1.5 0.4 80 14 103 255 12.3 0 12.5 12.2 08/17/2005 23:30:00 2.6 0.5 3.8 1.5 2.6 0.5 4.2 1.5 1.3 0.5 2.6 0.4 107 10 102 255 12.3 0 12.2 12.2 08/17/2005 23:40:00 2.5 0.6 3.8 1.1 2.6 0.5 3.8 1.1 1.2 0.6 2.6 0.4 114 14 118 255 12.3 0 12.5 12.2 08/17/2005 23:50:00 1.5 0.6 2.6 0.4 1.5 0.5 3 0.4 0.5 0.3 1.9 0.4 115 16 113 255 12.4 0 12.5 12.2 08/18/2005 00:00:00 1.9 0.5 3 0.4 1.9 0.6 3.4 0.7 0.8 0.6 2.3 0.4 95 11 99 255 12.3 0 12.5 12.2 08/18/2005 00:10:00 2.4 0.6 3.8 1.1 2.5 0.5 3.8 1.1 1.2 0.7 3 0.4 103 12 106 255 12.3 0 12.5 12.2 08/18/2005 00:20:00 2.4 0.6 4.2 0.7 2.6 0.6 4.2 1.1 1.3 0.7 3.4 0.4 103 10 105 255 12.5 0 12.7 12.5 08/18/2005 00:30:00 2.3 0.7 4.2 0.4 2.5 0.6 4.2 1.1 1.2 0.7 3 0.4 101 9 99 255 12.5 0 12.7 12.5 08/18/2005 00:40:00 2.7 0.5 4.2 1.1 2.8 0.5 4.2 1.5 1.4 0.7 3 0.4 97 11 108 255 12.7 0 12.7 12.5 08/18/2005 00:50:00 2.5 0.6 3.8 0.7 2.6 0.5 3.8 1.1 1.3 0.6 3 0.4 101 11 100 255 12.7 0 12.7 12.5 08/18/2005 01:00:00 2.9 0.6 4.6 1.1 3 0.6 4.6 1.5 1.9 0.8 3.4 0.4 105 10 100 255 12.7 0 12.7 12.5 08/18/2005 01:10:00 2.9 0.5 4.2 1.1 3 0.5 4.2 1.5 1.8 0.8 3.4 0.4 110 11 107 255 12.7 0 12.7 12.5 08/18/2005 01:20:00 2.9 0.6 4.2 1.1 3 0.6 4.2 1.5 1.7 0.6 3.4 0.4 110 12 108 255 12.7 0 12.7 12.5 08/18/2005 01:30:00 3.1 0.7 4.6 0.4 3.3 0.6 5.3 1.1 1.8 0.7 3.4 0.4 114 15 131 255 12.7 0 12.7 12.5 08/18/2005 01:40:00 3 0.7 4.6 1.5 3.1 0.7 4.6 1.5 1.9 0.8 3.8 0.4 108 13 116 255 12.7 0 12.7 12.7 08/18/2005 01:50:00 3.2 0.7 4.9 1.5 3.4 0.6 4.9 1.9 2.1 0.8 4.2 0.4 109 14 109 255 12.7 0 12.7 12.5 08/18/2005 02:00:00 3.1 0.8 4.9 1.5 3.4 0.6 4.9 1.5 2.1 0.8 4.2 0.4 109 14 90 255 12.7 0 12.7 12.7 08/18/2005 02:10:00 3.3 0.8 4.9 0.7 3.5 0.7 4.9 1.5 2.4 0.9 4.2 0.4 110 13 113 255 12.7 0 12.7 12.7 08/18/2005 02:20:00 2.8 0.8 4.6 0.4 3.1 0.7 4.6 1.1 1.9 0.9 4.6 0.4 111 16 126 255 12.8 0 12.7 12.7 08/18/2005 02:30:00 3.1 0.6 4.9 1.5 3.3 0.6 4.9 1.9 2.3 0.7 3.8 0.4 118 13 101 255 12.8 0 12.7 12.7 08/18/2005 02:40:00 3.3 0.8 4.9 1.1 3.6 0.6 4.9 1.9 2.4 0.8 4.2 0.4 115 12 129 255 12.7 0 12.7 12.7 08/18/2005 02:50:00 3.3 0.7 5.3 1.1 3.5 0.6 5.3 1.9 2.5 0.6 4.2 0.7 116 11 103 255 12.8 0 12.7 12.7 08/18/2005 03:00:00 3.2 0.9 4.9 0.4 3.4 0.8 4.9 1.5 2.5 0.9 4.6 0.4 114 13 96 255 12.8 0 12.7 12.7 08/18/2005 03:10:00 2.8 0.9 4.9 0.7 3 0.7 5.3 1.1 1.9 0.7 3.4 0.4 114 15 114 255 12.8 0 13 12.7 08/18/2005 03:20:00 2.5 0.9 4.6 0.4 2.8 0.7 4.6 1.1 1.7 0.9 4.2 0.4 111 17 115 255 12.8 0 12.7 12.7 08/18/2005 03:30:00 2.1 0.7 3.4 0.4 2.4 0.5 3.8 0.7 1.3 0.6 3 0.4 106 15 101 255 12.8 0 12.7 12.7 08/18/2005 03:40:00 1.8 0.5 3 0.4 2.1 0.4 3 1.1 0.9 0.4 1.9 0.4 94 8 86 255 12.7 0 12.7 12.5 08/18/2005 03:50:00 1.9 0.5 3.4 0.7 2 0.4 3.4 1.1 0.7 0.4 2.3 0.4 99 16 92 255 12.5 0 12.7 12.5 08/18/2005 04:00:00 2 0.5 3 0.7 2.1 0.4 3 1.1 0.9 0.5 2.6 0.4 112 14 100 255 12.5 0 12.7 12.5 08/18/2005 04:10:00 2.2 0.6 3.4 0.4 2.2 0.5 3.4 1.1 0.9 0.6 2.3 0.4 103 13 109 255 12.6 0 12.7 12.5 08/18/2005 04:20:00 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 0.4 0.2 1.5 0.4 92 16 86 255 12.7 0 12.7 12.5 08/18/2005 04:30:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 90 15 62 255 12.4 0 12.7 12.2 08/18/2005 04:40:00 1.4 0.5 3 0.4 1.4 0.5 3 0.4 0.5 0.3 1.9 0.4 87 17 89 255 12.3 0 12.5 12.2 08/18/2005 04:50:00 2.7 0.7 4.9 0.7 2.7 0.7 4.6 1.1 1.3 0.9 3.4 0.4 108 16 113 255 12.4 0.1 12.7 12.2 08/18/2005 05:00:00 3.9 1.1 6.5 1.5 3.9 1 6.8 1.5 2.9 1 5.3 0.4 108 17 126 255 12.8 0 13 12.7 08/18/2005 05:10:00 4.3 1 6.5 1.5 4.3 0.9 6.5 1.5 3.1 1.2 6.5 0.4 112 18 115 255 13.1 0 13.3 13 08/18/2005 05:20:00 4.6 1.1 6.8 1.9 4.7 1 6.8 2.3 3.6 1.1 6.1 0.7 108 16 81 255 13.2 0 13.3 13 08/18/2005 05:30:00 3.9 1 6.5 1.9 4.1 0.9 6.5 2.3 3.1 1.2 5.7 0.4 106 17 102 255 13.2 0 13.3 13 08/18/2005 05:40:00 3.6 0.8 5.3 1.1 3.8 0.7 5.3 1.5 2.7 0.8 4.9 0.7 98 13 109 255 13.2 0 13.3 13 08/18/2005 05:50:00 4 0.9 6.1 1.1 4.1 0.8 6.1 1.9 3 0.9 5.3 1.1 107 13 99 255 13.2 0 13.3 13 08/18/2005 06:00:00 4 1 5.7 1.1 4.1 0.9 6.1 1.5 2.9 1 4.9 0.4 102 13 95 255 13.2 0 13.3 13 08/18/2005 06:10:00 3.7 0.7 5.3 1.9 3.8 0.7 5.7 1.9 2.7 0.8 4.9 0.7 107 13 96 255 13.2 0 13.3 13 08/18/2005 06:20:00 3.8 0.8 5.7 1.9 3.9 0.8 5.7 1.5 2.8 0.9 4.9 0.4 110 15 118 255 13.2 0 13.3 13 08/18/2005 06:30:00 3 0.8 5.3 1.1 3.2 0.7 4.9 1.5 2.2 0.8 4.6 0.4 111 15 107 255 13.3 0 13.3 13.3 08/18/2005 06:40:00 3.4 0.8 5.3 1.5 3.5 0.7 5.7 1.5 2.4 1 4.6 0.4 107 13 119 255 13.3 0 13.3 13.3 08/18/2005 06:50:00 3.1 0.8 4.9 0.4 3.2 0.7 4.9 1.1 2.3 0.8 4.6 0.4 110 17 119 255 13.3 0 13.5 13.3 08/18/2005 07:00:00 2.8 0.6 4.6 1.5 2.9 0.6 4.6 1.5 1.8 0.8 3.8 0.4 101 12 106 255 13.5 0 13.5 13.3 08/18/2005 07:10:00 2.1 0.6 3.4 0.4 2.3 0.5 3.8 1.1 1.2 0.6 2.3 0.4 99 17 68 255 13.5 0 13.5 13.5 08/18/2005 07:20:00 1.5 0.5 2.6 0.4 1.7 0.5 3 0.4 0.6 0.5 2.6 0.4 79 8 84 255 13.7 0 13.8 13.5 08/18/2005 07:30:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.4 0.2 1.9 0.4 73 11 78 255 13.9 0 14.4 13.8 08/18/2005 07:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 65 8 77 255 14.1 0 14.4 13.8 08/18/2005 07:50:00 1.5 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.7 0.6 2.3 0.4 97 12 112 255 14.5 0 14.6 14.4 08/18/2005 08:00:00 2.6 0.6 4.6 1.1 2.6 0.6 4.2 1.1 1.7 0.8 4.2 0.4 103 13 106 255 14.8 0 15.5 14.6 08/18/2005 08:10:00 2.7 0.4 3.8 1.5 2.7 0.4 4.2 1.5 2 0.6 3 0.4 95 11 107 255 15.2 0 16 15.2 08/18/2005 08:20:00 2.8 0.6 3.8 1.1 2.8 0.5 3.8 1.5 2.2 0.6 3.4 0.4 97 10 88 255 15.5 0 16.3 15.5 08/18/2005 08:30:00 2 0.9 3.8 0.4 2.2 0.7 4.2 0.7 1.2 0.8 3.4 0.4 86 19 96 255 16.1 0.2 16.8 15.7 08/18/2005 08:40:00 1.8 0.7 3.4 0.4 1.9 0.6 3.4 0.7 1.2 0.7 2.6 0.4 89 23 93 255 16.8 0 17.1 16.6 08/18/2005 08:50:00 1.7 0.6 3.4 0.4 1.8 0.6 3.8 0.4 1 0.5 2.6 0.4 96 21 77 255 17 0 17.4 16.8 08/18/2005 09:00:00 1.4 0.6 3 0.4 1.5 0.6 3 0.4 0.8 0.6 2.6 0.4 88 17 90 255 17.3 0.1 17.7 16.8 08/18/2005 09:10:00 1.6 0.5 2.6 0.4 1.6 0.4 2.6 0.4 0.9 0.5 2.3 0.4 95 14 94 255 18.2 0.3 18.8 17.4 08/18/2005 09:20:00 1.6 0.4 2.3 0.7 1.6 0.3 2.3 0.7 1.2 0.5 2.6 0.4 110 8 115 255 18.9 0 19.4 18.5 08/18/2005 09:30:00 1.4 0.4 2.3 0.4 1.5 0.4 2.6 0.4 1 0.5 2.3 0.4 97 22 101 255 19 0 19.4 18.5 08/18/2005 09:40:00 1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 51 43 25 255 19.3 0 19.4 19.1 08/18/2005 09:50:00 1.3 0.6 2.6 0.4 1.5 0.5 3 0.4 0.9 0.5 2.3 0.4 38 17 35 255 19.4 0 19.7 19.1 08/18/2005 10:00:00 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.7 0.5 2.3 0.4 17 26 359 255 19.3 0 20 19.1 08/18/2005 10:10:00 2.1 0.9 3.8 0.4 2.1 0.8 3.8 0.7 1.4 1 4.2 0.4 30 22 66 255 19.7 0 20.5 19.4 08/18/2005 10:20:00 3.2 1.1 5.7 0.4 3.1 1 5.7 0.7 2.6 1.1 4.6 0.4 48 19 50 255 20.4 0.3 21.1 20 08/18/2005 10:30:00 3.7 1 6.1 0.7 3.9 0.8 5.7 1.1 3.1 1 5.3 0.7 25 16 40 255 20.5 0 21.1 20.3 08/18/2005 10:40:00 3.4 0.8 5.3 1.5 3.6 0.8 5.7 1.5 2.4 1.2 5.3 0.4 11 15 22 255 20.9 0 21.1 20.5 08/18/2005 10:50:00 3.1 0.6 4.6 1.5 3.3 0.6 4.6 1.9 2.7 0.7 4.2 0.7 42 19 34 255 21.1 0 21.7 20.8 08/18/2005 11:00:00 2.6 1 4.6 0.4 2.8 0.8 4.9 0.4 2.1 0.9 4.2 0.4 37 23 63 255 21 0.1 21.4 20.5 08/18/2005 11:10:00 2.1 0.8 4.2 0.4 2.5 0.7 4.2 1.1 1.8 0.9 4.2 0.4 30 22 12 255 21.3 0 21.7 21.1 08/18/2005 11:20:00 3 1.1 5.3 0.7 3.1 1.1 5.7 1.1 2.2 1.1 4.6 0.4 353 21 7 255 21.6 0 21.7 21.4 08/18/2005 11:30:00 4 0.9 5.7 1.1 4.1 0.9 5.7 1.9 3.2 1.1 5.7 0.4 18 19 30 255 21.8 0 22.3 21.7 08/18/2005 11:40:00 3.2 1 5.3 0.4 3.3 0.9 5.3 0.7 2.7 1 5.7 0.4 8 27 3 255 21.4 0 22 21.1 08/18/2005 11:50:00 3.5 1 6.1 0.4 3.6 1 6.1 1.1 2.8 0.9 5.3 1.1 21 19 13 255 21.6 0 22.3 21.4 08/18/2005 12:00:00 2.6 0.9 4.6 0.4 2.7 0.8 4.6 0.7 2 0.8 3.8 0.4 18 32 7 255 22.1 0 22.6 21.7 08/18/2005 12:10:00 2.7 0.8 4.6 0.7 2.9 0.7 4.2 0.7 2.4 0.9 4.2 0.4 16 22 12 255 22.1 0 22.6 22 08/18/2005 12:20:00 2.2 0.8 4.6 0.4 2.3 0.7 3.8 0.7 1.7 0.8 3.4 0.4 24 27 302 255 22.4 0 22.9 22 08/18/2005 12:30:00 2.1 0.8 4.2 0.7 2.1 0.8 4.2 0.7 1.5 1 4.2 0.4 38 24 44 255 22.2 0 22.3 22 08/18/2005 12:40:00 3.2 0.7 4.9 1.5 3.2 0.8 5.3 1.1 2.3 0.8 4.9 0.4 3 19 347 255 22.5 0.2 22.9 22 08/18/2005 12:50:00 2 1.1 4.6 0.4 2 1.1 4.6 0.4 1.3 0.9 3.8 0.4 322 58 342 255 22.1 0.2 22.6 21.4 08/18/2005 13:00:00 2.4 1.1 5.3 0.4 2.5 1 4.9 0.4 1.9 1 4.6 0.4 276 33 274 255 21.9 0.3 22.3 21.1 08/18/2005 13:10:00 2.2 1.2 5.3 0.4 2.3 1.1 5.7 0.4 1.8 1 4.9 0.4 290 35 282 255 22.1 0 22.3 21.7 08/18/2005 13:20:00 2.4 0.9 4.6 0.4 2.4 0.9 4.6 0.4 1.8 0.9 3.8 0.4 296 23 286 255 21.9 0.3 22.9 21.4 08/18/2005 13:30:00 3.1 1 5.7 0.7 3.1 1 5.7 1.1 2.3 1.2 4.9 0.4 297 23 299 255 22.4 0.6 23.2 21.1 08/18/2005 13:40:00 3.6 0.9 5.3 0.7 3.5 0.9 5.3 1.1 3 1 5.3 0.4 310 16 321 255 21.2 0.4 21.7 20.8 08/18/2005 13:50:00 3.3 0.9 5.3 1.1 3.2 0.9 4.9 1.1 2.6 1 4.6 0.4 306 21 296 255 21.9 0.2 22.6 21.4 08/18/2005 14:00:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 2.8 1 5.3 0.4 306 15 308 255 21.9 0.3 22.6 21.4 08/18/2005 14:10:00 2.3 1 4.6 0.4 2.3 1 4.6 0.4 1.8 0.9 4.2 0.4 291 43 297 255 22.6 0.2 23.2 22.3 08/18/2005 14:20:00 1.8 1 4.2 0.4 2 1 4.2 0.4 1.6 0.9 4.2 0.4 284 33 255 255 21.4 0.2 22.3 21.1 08/18/2005 14:30:00 2.4 1 4.6 0.4 2.4 0.9 3.8 0.4 1.8 1 3.8 0.4 314 27 339 255 20.9 0.1 21.1 20.5 08/18/2005 14:40:00 2.3 0.8 4.2 0.4 2.4 0.7 4.2 0.7 2 0.9 3.8 0.4 289 19 286 255 20.1 0 20.5 20 08/18/2005 14:50:00 2.1 0.5 3 0.4 2.2 0.5 3 0.7 1.7 0.6 3 0.4 298 16 301 255 20 0 20.3 20 08/18/2005 15:00:00 1.9 0.8 4.6 0.4 2 0.7 3.8 0.4 1.5 0.9 4.2 0.4 315 26 342 255 20.9 0.7 22 20 08/18/2005 15:10:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 0.7 2 1 4.2 0.4 315 21 317 255 21.6 0.1 22 21.1 08/18/2005 15:20:00 2.5 0.8 4.2 0.4 2.5 0.8 4.6 0.4 1.8 0.7 3.4 0.4 289 20 290 255 20.5 0.3 21.1 20 08/18/2005 15:30:00 2.3 0.8 4.2 0.4 2.4 0.7 4.2 0.4 1.8 0.8 3.4 0.4 290 13 313 255 19.9 0 20.3 19.7 08/18/2005 15:40:00 2.4 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.8 1 3.8 0.4 310 35 314 255 20 0 20 20 08/18/2005 15:50:00 1.7 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.1 0.8 3.4 0.4 298 33 318 255 20.3 0 20.5 20 08/18/2005 16:00:00 1.7 0.7 3.4 0.4 1.6 0.7 3 0.4 1 0.7 2.6 0.4 294 29 303 255 20.5 0 20.8 20.3 08/18/2005 16:10:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 0.8 0.6 2.6 0.4 303 45 268 255 20.8 0.2 21.4 20.5 08/18/2005 16:20:00 2.7 1 4.9 0.4 2.6 1 4.9 0.4 2 1 4.6 0.4 294 17 294 255 21.5 0 22 21.1 08/18/2005 16:30:00 2.4 0.7 3.8 0.7 2.2 0.7 3.8 0.4 1.8 0.8 3.8 0.4 290 22 291 255 21.5 0.1 21.7 21.1 08/18/2005 16:40:00 2.1 0.6 3.8 0.4 2 0.6 3.8 0.4 1.6 0.7 3 0.4 301 19 312 255 21 0 21.1 21.1 08/18/2005 16:50:00 3.1 0.8 5.7 1.1 3 0.8 5.3 1.1 2.3 0.8 4.2 0.4 296 20 297 255 21.2 0 21.4 21.1 08/18/2005 17:00:00 2.3 1 4.6 0.4 2.3 1 4.6 0.4 1.5 1.1 4.6 0.4 307 22 283 255 21.1 0 21.4 21.1 08/18/2005 17:10:00 2.6 0.9 4.9 1.1 2.5 0.9 5.3 0.7 1.7 1.1 5.3 0.4 310 28 305 255 21.1 0 21.4 21.1 08/18/2005 17:20:00 3.1 0.7 4.9 0.7 3 0.7 4.9 0.4 2.3 0.8 4.6 0.4 305 15 298 255 21.1 0 21.4 20.8 08/18/2005 17:30:00 2.6 0.8 4.6 0.4 2.5 0.7 4.6 0.4 1.9 0.8 3.8 0.4 310 13 308 255 20.8 0.2 21.1 20.5 08/18/2005 17:40:00 2.5 0.6 4.2 0.7 2.4 0.5 3.8 0.7 1.9 0.7 3.4 0.4 295 16 306 255 20.6 0 21.1 20.5 08/18/2005 17:50:00 1.9 0.7 3.8 0.4 1.7 0.6 3.4 0.4 1.2 0.7 3 0.4 308 15 307 255 20.4 0.1 20.8 20 08/18/2005 18:00:00 2.4 0.9 4.2 0.4 2.2 0.9 4.2 0.4 1.6 0.9 3.8 0.4 311 16 298 255 20.2 0 20.8 20 08/18/2005 18:10:00 2.5 0.7 3.8 0.4 2.3 0.7 3.8 0.4 1.4 0.8 3.4 0.4 309 17 308 255 20 0 20.5 19.7 08/18/2005 18:20:00 1.6 0.6 3 0.4 1.4 0.5 3 0.4 0.8 0.5 2.6 0.4 319 11 301 255 19.8 0 20.3 19.7 08/18/2005 18:30:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 317 0 317 255 19.7 0 20.3 19.7 08/18/2005 18:40:00 1.6 0.8 3 0.4 1.4 0.7 3 0.4 0.7 0.5 2.3 0.4 317 12 327 255 19.7 0.1 20.3 19.4 08/18/2005 18:50:00 2.1 0.4 3 1.1 1.9 0.4 2.6 0.7 0.9 0.5 1.9 0.4 311 9 322 255 19.5 0 20 19.4 08/18/2005 19:00:00 1.5 0.6 2.6 0.4 1.3 0.5 2.6 0.4 0.7 0.4 1.9 0.4 344 16 314 255 19.3 0 19.7 19.1 08/18/2005 19:10:00 1.2 0.5 2.3 0.4 1 0.4 2.3 0.4 0.4 0 0.7 0.4 346 21 332 255 19.2 0.1 19.7 18.8 08/18/2005 19:20:00 2.3 0.4 3.4 1.1 2.2 0.4 3.4 0.7 1.2 0.6 2.6 0.4 15 8 4 255 18.9 0 19.4 18.5 08/18/2005 19:30:00 2.3 0.5 3 0.4 2.1 0.5 3 0.7 0.9 0.6 2.3 0.4 11 9 356 255 18.5 0.1 18.8 18.2 08/18/2005 19:40:00 1.9 0.6 2.6 0.4 1.8 0.5 2.6 0.4 1 0.6 2.3 0.4 19 9 16 255 18 0 18.2 17.7 08/18/2005 19:50:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 18 13 15 255 17.5 0.1 18 17.1 08/18/2005 20:00:00 1.4 0.6 2.6 0.4 1.2 0.5 2.6 0.4 0.6 0.4 2.3 0.4 14 17 353 255 17.3 0 17.4 16.8 08/18/2005 20:10:00 2.1 0.4 3.4 1.1 1.8 0.5 3 0.7 0.8 0.5 2.3 0.4 351 12 0 255 16.9 0 17.1 16.8 08/18/2005 20:20:00 1.5 0.6 2.6 0.4 1.3 0.5 2.6 0.4 0.6 0.4 1.9 0.4 29 26 42 255 16.6 0 16.8 16.3 08/18/2005 20:30:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.8 0.5 2.3 0.4 53 19 65 255 16.4 0 16.8 16.3 08/18/2005 20:40:00 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 43 0 43 255 16.2 0.1 16.8 16 08/18/2005 20:50:00 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 0.4 0.2 1.1 0.4 47 15 56 255 15.7 0 16.3 15.5 08/18/2005 21:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 88 23 69 255 15.2 0.2 15.7 15.2 08/18/2005 21:10:00 1.4 0.3 1.9 0.7 1.1 0.3 1.9 0.7 0.4 0.2 1.1 0.4 109 9 113 255 15 0 15.5 14.9 08/18/2005 21:20:00 1.3 0.3 1.9 0.4 1 0.3 1.9 0.4 0.4 0.2 1.5 0.4 102 28 127 255 15 0 15.7 14.9 08/18/2005 21:30:00 1.9 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.1 0.5 2.3 0.4 55 8 61 255 15.1 0.1 15.7 15.2 08/18/2005 21:40:00 2.1 0.4 3 1.5 1.9 0.4 3 1.1 0.8 0.5 2.3 0.4 50 10 34 255 15.4 0.1 15.7 15.2 08/18/2005 21:50:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.7 0.5 2.3 0.4 56 11 60 255 15.4 0 16 15.2 08/18/2005 22:00:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.6 0.8 3 0.4 48 11 41 255 15.6 0 16 15.5 08/18/2005 22:10:00 3.3 0.5 4.6 1.9 3.2 0.5 4.9 1.9 2.5 0.6 3.8 0.7 31 12 49 255 15.6 0 16 15.5 08/18/2005 22:20:00 2.8 0.7 4.9 1.9 2.7 0.7 4.9 1.5 1.8 0.7 4.2 0.4 20 12 6 255 15.4 0 16 15.2 08/18/2005 22:30:00 2.6 0.5 3.8 1.1 2.6 0.6 4.2 1.1 2 0.7 3.8 0.4 30 15 43 255 15.3 0 15.7 15.2 08/18/2005 22:40:00 2.2 0.6 3.4 0.4 2.1 0.6 3.4 0.7 1.5 0.7 3 0.4 29 17 26 255 15.1 0.1 15.7 15.2 08/18/2005 22:50:00 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.5 0.3 1.9 0.4 44 28 51 255 15 0 15.7 14.9 08/18/2005 23:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.7 0.4 1.9 0.4 67 14 41 255 14.9 0 15.5 14.9 08/18/2005 23:10:00 1.9 0.6 2.6 0.4 1.8 0.6 2.6 0.4 1.2 0.6 2.3 0.4 46 10 42 255 14.9 0 15.5 14.9 08/18/2005 23:20:00 2.4 0.5 3.4 1.1 2.3 0.4 3.4 1.1 1.5 0.6 3 0.4 44 15 42 255 14.8 0 15.5 14.9 08/18/2005 23:30:00 1 0.7 2.6 0.4 1 0.6 2.6 0.4 0.6 0.5 2.3 0.4 86 14 52 255 14.8 0 15.5 14.6 08/18/2005 23:40:00 0.9 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 76 13 67 255 14.7 0.1 15.2 14.6 08/18/2005 23:50:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.6 0.4 1.9 0.4 63 13 45 255 14.6 0 15.2 14.6 08/19/2005 00:00:00 1.2 0.8 3 0.4 1.1 0.7 2.6 0.4 0.7 0.5 1.9 0.4 63 8 58 255 14.5 0 15.2 14.4 08/19/2005 00:10:00 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 67 14 94 255 14.3 0 14.6 14.4 08/19/2005 00:20:00 1.2 0.7 2.6 0.4 1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 78 11 69 255 14.1 0 14.6 13.8 08/19/2005 00:30:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.6 0.4 1.9 0.4 67 13 45 255 13.9 0 14.6 13.8 08/19/2005 00:40:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.5 0.4 93 21 55 255 13.9 0 14.4 13.8 08/19/2005 00:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 189 39 255 255 13.9 0 14.4 13.8 08/19/2005 01:00:00 0.7 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 64 9 68 255 13.9 0 14.4 13.8 08/19/2005 01:10:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.5 0.4 43 22 63 255 13.9 0 14.4 13.8 08/19/2005 01:20:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 28 6 30 255 13.9 0 14.4 13.8 08/19/2005 01:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 5 0 6 255 13.9 0 14.6 13.8 08/19/2005 01:40:00 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 5 0 6 255 13.9 0 14.4 13.8 08/19/2005 01:50:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 311 36 351 255 13.9 0 14.4 13.8 08/19/2005 02:00:00 0.9 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 289 10 280 255 13.9 0 14.4 13.8 08/19/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 14.2 0.1 14.6 13.8 08/19/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 255 255 14.2 0.1 14.6 13.8 08/19/2005 02:30:00 1 0.6 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0.1 0.7 0.4 358 23 358 255 14.1 0.1 14.6 13.8 08/19/2005 02:40:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 357 10 255 255 14.1 0.1 14.6 14.1 08/19/2005 02:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 325 23 278 255 14.1 0.1 14.6 13.8 08/19/2005 03:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 320 0 320 255 14.1 0.1 14.6 13.8 08/19/2005 03:10:00 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 323 7 320 255 14.1 0.1 14.6 14.1 08/19/2005 03:20:00 1.3 0.7 2.6 0.4 1.2 0.6 2.3 0.4 0.6 0.4 1.9 0.4 309 17 298 255 14.1 0.1 14.6 14.1 08/19/2005 03:30:00 2.4 0.5 3.4 0.7 2.2 0.5 3.8 0.7 1.3 0.7 3 0.4 295 13 291 255 14.2 0 14.6 14.1 08/19/2005 03:40:00 1.9 0.8 3.8 0.4 1.8 0.7 3.4 0.4 0.9 0.6 2.3 0.4 283 19 253 255 14.2 0 14.6 14.4 08/19/2005 03:50:00 2.1 0.7 3.8 0.4 2 0.8 3.8 0.4 1 0.7 2.6 0.4 284 21 278 255 14.2 0 14.6 14.4 08/19/2005 04:00:00 1.9 0.9 3.8 0.4 1.8 0.8 3.8 0.4 1 0.7 2.6 0.4 301 22 306 255 14.2 0 14.9 14.4 08/19/2005 04:10:00 1.7 0.8 4.2 0.4 1.6 0.7 4.2 0.4 0.8 0.6 2.6 0.4 297 21 262 255 14.2 0 14.6 14.4 08/19/2005 04:20:00 2.4 0.6 3.8 1.1 2.3 0.6 3.8 0.7 1.3 0.7 3.4 0.4 298 15 294 255 14.2 0 14.6 14.1 08/19/2005 04:30:00 2.2 0.7 4.2 0.4 2.2 0.6 4.2 0.7 1.3 0.8 3.4 0.4 297 17 263 255 14.1 0 14.6 13.8 08/19/2005 04:40:00 2.2 0.7 4.2 0.7 2.1 0.7 4.2 0.7 1.1 0.8 3.4 0.4 285 23 287 255 13.9 0 14.6 13.8 08/19/2005 04:50:00 1.7 0.8 3.8 0.4 1.6 0.9 4.2 0.4 0.8 0.6 2.6 0.4 272 26 268 255 13.9 0 14.6 13.8 08/19/2005 05:00:00 1.7 0.7 3.8 0.4 1.7 0.7 3.8 0.4 0.9 0.7 3 0.4 275 19 253 255 13.9 0 14.6 13.8 08/19/2005 05:10:00 1.7 0.8 4.9 0.4 1.5 0.8 4.6 0.4 0.7 0.5 3.4 0.4 289 22 268 255 13.9 0 14.6 13.8 08/19/2005 05:20:00 2.3 0.9 4.6 0.4 2.2 0.8 3.8 0.4 1.3 0.8 3.4 0.4 292 15 286 255 13.9 0 14.4 13.8 08/19/2005 05:30:00 2.8 0.7 4.6 1.1 2.6 0.7 4.2 0.7 1.8 0.9 3.8 0.4 284 15 289 255 13.9 0 14.4 13.8 08/19/2005 05:40:00 2.5 0.7 4.6 0.7 2.4 0.8 4.6 1.1 1.4 0.9 3.8 0.4 279 16 266 255 13.9 0 14.4 13.8 08/19/2005 05:50:00 2.4 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.4 0.8 3.8 0.4 282 19 274 255 13.9 0 14.4 13.8 08/19/2005 06:00:00 1.9 0.9 4.2 0.4 1.8 0.9 4.2 0.4 0.9 1 3.4 0.4 272 26 255 255 13.9 0 14.4 13.8 08/19/2005 06:10:00 2.8 0.8 4.6 0.7 2.7 0.8 4.9 0.7 1.6 0.8 3.8 0.4 271 17 253 255 13.9 0 14.4 13.8 08/19/2005 06:20:00 2.1 1 4.6 0.4 2.1 0.9 4.2 0.4 1 0.9 3.8 0.4 280 27 254 255 13.9 0 14.4 13.8 08/19/2005 06:30:00 2.4 1 4.6 0.4 2.3 1 4.6 0.4 1.1 0.8 3 0.4 270 22 271 255 13.9 0 14.4 13.8 08/19/2005 06:40:00 2.3 1 5.3 0.4 2.2 1 4.9 0.4 1.3 0.9 3.8 0.4 277 23 286 255 13.9 0 14.4 13.8 08/19/2005 06:50:00 2.4 1.2 5.3 0.4 2.4 1.1 5.3 0.4 1.5 1.1 4.6 0.4 273 29 262 255 13.9 0 14.4 13.8 08/19/2005 07:00:00 2.4 0.8 4.6 0.4 2.4 0.8 4.2 0.4 1.3 0.8 3.4 0.4 274 18 276 255 13.9 0 14.4 13.8 08/19/2005 07:10:00 1.9 0.9 4.2 0.4 1.9 0.8 4.2 0.4 1 0.8 3.4 0.4 267 22 256 255 13.9 0 14.4 13.8 08/19/2005 07:20:00 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.6 0.5 2.6 0.4 281 26 253 255 13.9 0 14.6 13.8 08/19/2005 07:30:00 1.4 0.8 3.4 0.4 1.3 0.8 3 0.4 0.7 0.6 2.6 0.4 278 30 253 255 14 0.1 14.6 13.8 08/19/2005 07:40:00 1.5 1 4.2 0.4 1.4 1 4.2 0.4 0.6 0.6 3 0.4 283 19 268 255 14.1 0.1 14.6 14.1 08/19/2005 07:50:00 2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.1 0.8 3.4 0.4 278 24 263 255 14 0.1 14.6 13.8 08/19/2005 08:00:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 0.6 0.5 2.3 0.4 290 23 286 255 14.1 0.1 14.6 13.8 08/19/2005 08:10:00 2.1 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.2 0.8 3 0.4 292 27 283 255 14.1 0 14.6 14.1 08/19/2005 08:20:00 2.3 0.9 4.2 0.4 2.2 0.9 4.2 0.4 1.1 0.9 4.2 0.4 286 26 276 255 14.2 0 14.6 14.1 08/19/2005 08:30:00 2.4 0.9 4.6 0.4 2.3 0.9 4.6 0.4 1.5 1 3.8 0.4 279 23 268 255 14.1 0 14.6 13.8 08/19/2005 08:40:00 2.2 0.8 3.8 0.4 2 0.9 3.8 0.4 1.1 0.8 3.8 0.4 278 20 267 255 14 0.1 14.6 13.8 08/19/2005 08:50:00 2.2 0.9 4.2 0.4 2.1 0.9 4.2 0.4 1.2 0.9 3.8 0.4 280 23 304 255 14.1 0.1 14.6 13.8 08/19/2005 09:00:00 1.7 0.9 4.2 0.4 1.6 0.9 3.8 0.4 0.7 0.6 3 0.4 262 22 251 255 14.2 0 14.6 14.1 08/19/2005 09:10:00 1.9 0.9 3.8 0.4 1.8 0.9 3.4 0.4 1.2 0.8 3 0.4 283 26 260 255 14.2 0 14.9 14.4 08/19/2005 09:20:00 2 0.6 4.2 0.7 1.8 0.6 4.2 0.7 0.9 0.7 3 0.4 261 18 255 255 14.4 0 14.9 14.4 08/19/2005 09:30:00 1.8 0.8 3.8 0.4 1.7 0.9 3.8 0.4 0.8 0.7 3 0.4 262 29 260 255 14.5 0 15.2 14.4 08/19/2005 09:40:00 1.7 0.8 3.8 0.4 1.5 0.9 3.8 0.4 0.7 0.6 2.6 0.4 285 22 269 255 14.6 0.1 15.2 14.6 08/19/2005 09:50:00 2.2 0.7 3.8 0.4 2.1 0.7 3.4 0.4 1.2 0.8 3.4 0.4 275 22 268 255 14.6 0 14.9 14.6 08/19/2005 10:00:00 1.9 0.6 3.8 0.7 1.9 0.7 3.8 0.4 1.1 0.7 3.4 0.4 280 22 283 255 14.5 0 14.9 14.6 08/19/2005 10:10:00 2.5 0.8 4.2 0.4 2.5 0.7 4.2 0.7 1.5 0.8 3.8 0.4 273 15 252 255 14.6 0.1 15.2 14.6 08/19/2005 10:20:00 1.9 0.5 3 0.4 1.8 0.6 3 0.4 0.9 0.7 3 0.4 273 18 264 255 14.6 0 15.2 14.6 08/19/2005 10:30:00 2.1 0.8 3.8 0.4 2.1 0.7 3.4 0.4 1.2 0.9 3 0.4 264 15 275 255 14.7 0 15.2 14.6 08/19/2005 10:40:00 1.8 1 3.8 0.4 1.8 0.9 3.4 0.4 0.8 0.6 3 0.4 282 18 253 255 14.9 0 15.2 14.9 08/19/2005 10:50:00 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.7 0.5 2.6 0.4 279 24 280 255 15.1 0 15.7 15.2 08/19/2005 11:00:00 1.4 0.8 3 0.4 1.4 0.7 3.4 0.4 0.7 0.5 2.6 0.4 279 23 271 255 15.3 0 16 15.2 08/19/2005 11:10:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.5 0.4 1.9 0.4 274 19 300 255 15.7 0 16 15.5 08/19/2005 11:20:00 2.3 0.7 3.4 0.4 2.2 0.6 3.4 0.4 1.4 0.8 3 0.4 285 15 295 255 15.7 0 16.3 15.5 08/19/2005 11:30:00 2.1 0.7 3.4 0.4 1.9 0.8 3.4 0.4 1 0.7 3.4 0.4 279 28 291 255 15.7 0 16.3 15.5 08/19/2005 11:40:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.5 0.4 1.9 0.4 266 21 260 255 15.9 0.2 16.6 15.7 08/19/2005 11:50:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.5 0.4 1.9 0.4 284 21 303 255 16.3 0.1 16.8 16 08/19/2005 12:00:00 1.5 0.8 3 0.4 1.4 0.7 2.6 0.4 0.7 0.5 2.3 0.4 289 23 289 255 16.1 0 16.3 15.7 08/19/2005 12:10:00 1.9 0.6 3.4 0.7 1.7 0.7 3.4 0.4 1.1 0.7 3.4 0.4 300 17 298 255 15.8 0 16.3 15.7 08/19/2005 12:20:00 1.8 0.5 3 0.7 1.7 0.5 3 0.4 0.8 0.5 2.3 0.4 303 15 300 255 15.9 0 16.3 15.7 08/19/2005 12:30:00 2.1 0.5 3 0.7 1.9 0.5 3 0.7 0.9 0.6 2.3 0.4 304 12 310 255 16.2 0.1 16.6 16 08/19/2005 12:40:00 2.3 0.5 3.4 1.1 2.2 0.5 3 0.7 1.3 0.6 2.6 0.4 306 16 316 255 16.4 0 16.8 16.3 08/19/2005 12:50:00 2.1 0.6 3.4 0.4 2 0.7 3.4 0.4 1 0.7 3 0.4 299 15 290 255 16.6 0 16.8 16.6 08/19/2005 13:00:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 0.7 0.5 2.3 0.4 308 11 330 255 16.6 0 16.8 16.6 08/19/2005 13:10:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1 0.5 2.6 0.4 300 9 299 255 16.6 0 16.8 16.6 08/19/2005 13:20:00 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 0.6 0.5 2.3 0.4 310 14 318 255 16.8 0 17.4 16.6 08/19/2005 13:30:00 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.5 0.4 1.9 0.4 311 17 290 255 17.1 0 17.4 16.8 08/19/2005 13:40:00 1.6 0.8 3 0.4 1.5 0.8 3 0.4 0.7 0.6 2.6 0.4 356 21 16 255 17.5 0.1 18 17.1 08/19/2005 13:50:00 2.1 0.6 3 0.4 1.9 0.7 3 0.4 1.3 0.7 2.6 0.4 22 22 21 255 17.8 0 18.2 17.4 08/19/2005 14:00:00 2.7 0.4 3.8 1.1 2.6 0.5 3.8 1.1 2 0.7 3.4 0.4 49 11 66 255 17.3 0.1 17.7 16.8 08/19/2005 14:10:00 2.5 0.5 3.8 0.7 2.4 0.6 3.4 0.7 1.9 0.6 3.4 0.4 30 17 31 255 17.2 0.2 17.7 16.8 08/19/2005 14:20:00 2.9 0.6 4.2 1.5 2.9 0.6 4.2 1.5 2.3 0.8 3.8 0.4 41 12 41 255 17.3 0.1 17.7 17.1 08/19/2005 14:30:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.1 2 0.8 3.4 0.4 32 18 33 255 17.8 0.1 18.2 17.1 08/19/2005 14:40:00 2.7 0.5 3.8 1.5 2.7 0.6 3.8 1.1 1.8 0.8 3.4 0.4 23 17 12 255 18 0.3 18.5 17.7 08/19/2005 14:50:00 3.1 0.6 4.6 1.5 3 0.7 4.6 1.1 2.4 0.7 3.8 0.4 22 15 17 255 18.7 0.1 19.4 18.5 08/19/2005 15:00:00 2.8 0.6 4.9 1.5 2.8 0.6 4.6 1.5 2.1 0.7 3.8 0.4 24 15 14 255 18.9 0 19.4 18.5 08/19/2005 15:10:00 2.8 0.6 4.2 1.5 2.6 0.6 4.6 0.7 1.7 0.9 3.8 0.4 6 19 12 255 19.2 0 19.7 19.1 08/19/2005 15:20:00 2.4 0.6 4.2 0.7 2.2 0.6 3.8 0.7 1.4 0.8 3.8 0.4 357 15 346 255 19.5 0 20 19.4 08/19/2005 15:30:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.7 1.9 0.7 3.8 0.4 9 12 15 255 19.5 0 20 19.1 08/19/2005 15:40:00 2.5 0.5 3.4 1.1 2.5 0.5 3.4 0.7 1.6 0.8 3.4 0.4 17 24 6 255 19.3 0 19.7 19.1 08/19/2005 15:50:00 2.4 0.5 4.2 1.1 2.3 0.5 4.2 0.7 1.7 0.6 3.4 0.4 10 17 33 255 19.2 0 19.7 18.8 08/19/2005 16:00:00 2.8 0.6 4.6 1.5 2.7 0.6 4.2 1.1 1.5 0.9 3.4 0.4 357 16 334 255 19 0.2 19.7 18.8 08/19/2005 16:10:00 2.6 0.9 4.2 0.4 2.3 0.8 3.8 0.4 1.2 0.9 3.8 0.4 355 18 346 255 19.5 0 20 19.1 08/19/2005 16:20:00 2.5 0.6 3.8 0.4 2.3 0.7 3.8 0.4 1.2 0.7 3 0.4 353 17 338 255 19.1 0.3 20 18.5 08/19/2005 16:30:00 2.5 0.8 4.6 0.7 2.3 0.8 4.6 0.7 1.4 0.8 3 0.4 352 19 335 255 18.7 0.2 19.4 18.2 08/19/2005 16:40:00 2.7 0.6 3.8 0.4 2.6 0.6 3.8 0.7 2.1 0.9 3.8 0.4 13 15 22 255 18.2 0 18.8 18.2 08/19/2005 16:50:00 3 0.5 4.2 1.9 2.9 0.5 4.6 1.5 2.3 0.6 4.2 0.7 30 16 25 255 18.1 0 18.5 18 08/19/2005 17:00:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.1 2.1 0.7 3.4 0.4 26 15 35 255 18 0 18.2 17.7 08/19/2005 17:10:00 3 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2 0.7 3.4 0.4 5 15 340 255 17.9 0 18.2 17.7 08/19/2005 17:20:00 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.5 2.2 0.8 3.8 0.4 9 14 358 255 17.8 0 18 17.7 08/19/2005 17:30:00 3.6 0.4 4.6 2.3 3.5 0.4 4.6 1.9 2.6 0.8 4.2 1.1 9 9 10 255 17.6 0 17.7 17.4 08/19/2005 17:40:00 3.8 0.7 5.3 1.9 3.7 0.7 5.3 1.9 2.8 1.1 4.6 0.4 12 11 18 255 17.4 0 17.4 17.1 08/19/2005 17:50:00 2.9 0.7 4.6 1.1 2.8 0.7 4.6 1.1 2 1 4.2 0.4 22 15 25 255 17.3 0 17.4 17.1 08/19/2005 18:00:00 4 0.4 4.9 2.6 4 0.4 4.9 2.3 3.5 0.6 4.9 1.9 20 7 12 255 17.3 0 17.7 17.1 08/19/2005 18:10:00 3.5 0.7 4.9 1.9 3.4 0.7 4.9 1.9 2.5 0.9 4.2 0.7 23 13 34 255 17.3 0 17.7 17.1 08/19/2005 18:20:00 4.1 0.7 5.3 1.5 4 0.7 5.3 1.5 3.3 1 5.3 0.4 19 10 28 255 17.2 0 17.7 16.8 08/19/2005 18:30:00 4 0.6 5.7 2.6 4 0.6 5.3 2.6 3.1 0.7 4.6 1.1 17 9 17 255 16.9 0.1 17.4 16.8 08/19/2005 18:40:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 2.6 0.7 4.2 0.7 14 9 7 255 16.8 0 17.1 16.6 08/19/2005 18:50:00 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.5 0.6 3.8 0.7 31 15 37 255 16.6 0 17.1 16.6 08/19/2005 19:00:00 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.9 2.6 0.6 4.2 1.1 32 11 51 255 16.6 0 16.8 16.3 08/19/2005 19:10:00 2.8 0.5 3.8 1.5 2.8 0.6 4.2 1.1 2.1 0.8 3.8 0.4 27 10 29 255 16.2 0.1 16.8 16 08/19/2005 19:20:00 2.2 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1.1 0.7 3 0.4 15 9 18 255 15.9 0.2 16.6 15.7 08/19/2005 19:30:00 2.5 0.4 3.8 1.1 2.5 0.5 3.8 1.1 1.7 0.5 3 0.4 26 10 9 255 15.7 0 16.3 15.7 08/19/2005 19:40:00 2.2 0.7 3.8 0.7 2.2 0.7 3.8 0.7 1.4 0.8 3.4 0.4 28 14 41 255 15.5 0 16 15.2 08/19/2005 19:50:00 2 0.5 3.4 0.7 1.9 0.5 3 0.7 1.2 0.6 2.3 0.4 46 13 34 255 15.2 0.1 15.7 15.2 08/19/2005 20:00:00 1.8 0.5 3.4 0.7 1.7 0.5 3 0.4 0.7 0.4 1.9 0.4 57 13 44 255 15.1 0.1 15.7 14.9 08/19/2005 20:10:00 1.9 0.4 3 0.7 1.8 0.4 2.6 0.7 0.9 0.4 1.9 0.4 68 12 54 255 14.7 0.1 15.5 14.4 08/19/2005 20:20:00 2.1 0.4 3 1.1 2 0.4 3 1.1 1.1 0.5 2.3 0.4 75 10 79 255 14.2 0.1 14.9 14.1 08/19/2005 20:30:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.4 0.6 2.6 0.4 69 10 62 255 13.9 0 14.6 13.8 08/19/2005 20:40:00 2.5 0.6 4.2 1.1 2.6 0.5 3.8 1.1 1.4 0.7 3 0.4 71 12 51 255 13.7 0 14.4 13.5 08/19/2005 20:50:00 2.3 0.6 4.2 0.7 2.3 0.6 4.2 0.7 1.2 0.6 2.6 0.4 68 13 78 255 13.5 0 14.4 13.3 08/19/2005 21:00:00 2.4 0.6 3.8 1.1 2.5 0.6 3.8 1.1 1.1 0.6 2.6 0.4 71 17 74 255 13 0.2 13.8 12.7 08/19/2005 21:10:00 2.7 0.5 4.2 1.5 2.7 0.6 4.2 0.7 1.3 0.7 3 0.4 73 13 53 255 12.7 0 13 12.7 08/19/2005 21:20:00 3.1 0.6 4.6 1.5 3.2 0.5 4.6 1.9 2 0.7 3.8 0.4 74 12 64 255 12.7 0 13 12.5 08/19/2005 21:30:00 3.5 0.6 5.3 1.9 3.6 0.6 4.9 2.3 2.4 0.7 4.2 0.4 74 12 87 255 12.8 0 13.3 12.7 08/19/2005 21:40:00 2.6 0.7 4.6 1.1 2.7 0.6 4.6 1.1 1.3 0.7 3.4 0.4 72 12 54 255 13.1 0 13.5 12.7 08/19/2005 21:50:00 2.6 0.6 4.6 1.1 2.7 0.6 4.6 1.1 1.6 0.7 3.4 0.4 65 13 75 255 12.6 0 13 12.5 08/19/2005 22:00:00 3.1 0.6 5.3 1.5 3.1 0.6 4.9 1.9 1.9 0.7 3.4 0.4 50 13 53 255 12.7 0 13.3 12.5 08/19/2005 22:10:00 3.5 0.7 5.3 1.9 3.5 0.7 5.7 1.9 2.3 1 4.6 0.4 43 14 53 255 13 0.1 13.5 12.7 08/19/2005 22:20:00 2.7 0.6 4.6 1.5 2.8 0.6 4.6 1.5 1.5 0.6 3 0.4 41 11 42 255 13.3 0 13.5 13.3 08/19/2005 22:30:00 2.2 0.4 3 1.1 2.2 0.4 3.4 1.1 0.9 0.6 2.6 0.4 45 11 35 255 12.9 0.2 13.3 12.5 08/19/2005 22:40:00 2 0.6 3.4 0.4 2 0.6 3.4 0.4 0.6 0.5 1.9 0.4 54 11 55 255 12.1 0.2 12.5 11.7 08/19/2005 22:50:00 1.9 0.3 3 0.7 1.9 0.3 3 1.1 0.4 0.2 1.5 0.4 78 17 49 255 11.5 0 11.7 11.4 08/19/2005 23:00:00 2.8 0.3 3.8 1.9 2.8 0.3 3.4 1.9 1.5 0.5 2.6 0.4 94 9 103 255 11.3 0 11.4 11.1 08/19/2005 23:10:00 1.8 0.6 3.4 0.4 2 0.6 3.8 0.4 0.4 0.2 1.9 0.4 101 10 100 255 11 0 11.1 10.9 08/19/2005 23:20:00 1.9 0.3 2.6 1.1 2 0.3 2.6 1.1 0.4 0.1 1.1 0.4 104 10 105 255 10.9 0 11.1 10.9 08/19/2005 23:30:00 1.7 0.4 2.6 0.4 1.9 0.4 2.6 0.7 0.4 0.1 1.1 0.4 110 8 96 255 10.9 0 11.1 10.9 08/19/2005 23:40:00 2 0.4 3 1.1 2.1 0.4 3.4 1.5 0.4 0.2 1.5 0.4 79 11 66 255 10.9 0 11.1 10.9 08/19/2005 23:50:00 1.8 0.3 3 1.1 2 0.3 2.6 1.5 0.4 0.1 1.1 0.4 64 15 60 255 10.7 0 10.9 10.6 08/20/2005 00:00:00 0.9 0.6 1.9 0.4 1 0.6 1.9 0.4 0.4 0 0.4 0.4 47 0 45 255 10.6 0 10.9 10.6 08/20/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 10.6 0 10.6 10.6 08/20/2005 00:20:00 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 59 17 77 255 10.4 0 10.6 10.3 08/20/2005 00:30:00 1.1 0.2 1.5 0.7 1.2 0.2 1.5 0.7 0.4 0 0.4 0.4 88 4 83 255 10.3 0 10.3 10.3 08/20/2005 00:40:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 92 0 92 255 10.2 0 10.3 10.1 08/20/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 255 255 10.1 0 10.3 10.1 08/20/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 255 255 10.1 0 10.3 10.1 08/20/2005 01:10:00 0.9 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 81 15 59 255 10.3 0 10.3 10.1 08/20/2005 01:20:00 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 0.4 0.1 1.1 0.4 92 9 92 255 10.4 0 10.6 10.3 08/20/2005 01:30:00 1.7 0.3 2.3 0.7 1.7 0.3 2.3 0.7 0.4 0 0.4 0.4 92 12 91 255 10.5 0 10.6 10.6 08/20/2005 01:40:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 0.8 0.6 2.6 0.4 71 14 68 255 10.6 0 10.6 10.6 08/20/2005 01:50:00 2.6 0.4 3.8 1.5 2.7 0.4 3.4 1.5 1.2 0.5 2.6 0.4 58 9 55 255 10.5 0 10.6 10.3 08/20/2005 02:00:00 2.3 0.5 3.4 1.1 2.4 0.4 3.4 1.5 0.8 0.5 2.3 0.4 63 10 62 255 10.2 0 10.6 10.1 08/20/2005 02:10:00 2.2 0.5 3.4 1.1 2.3 0.5 3.8 1.1 0.9 0.6 2.3 0.4 61 8 43 255 10.1 0 10.3 10.1 08/20/2005 02:20:00 1.6 0.5 3 0.4 1.7 0.5 3 0.4 0.5 0.3 1.9 0.4 64 10 49 255 10 0 10.3 9.8 08/20/2005 02:30:00 1.9 0.4 2.6 0.7 2 0.4 2.6 1.1 0.4 0.2 1.5 0.4 68 6 65 255 9.9 0 10.1 9.8 08/20/2005 02:40:00 2.3 0.2 3 1.9 2.3 0.3 3 1.9 0.4 0.1 1.5 0.4 86 10 73 255 9.9 0 10.1 9.8 08/20/2005 02:50:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 0.9 0.6 2.6 0.4 104 8 95 255 9.7 0 9.8 9.6 08/20/2005 03:00:00 3 0.4 3.8 1.9 3 0.4 3.8 1.9 1.6 0.6 3.4 0.4 99 8 79 255 9.7 0 9.8 9.6 08/20/2005 03:10:00 2.6 0.6 4.2 1.1 2.6 0.5 4.2 1.1 1.2 0.7 3 0.4 114 14 112 255 9.8 0.1 10.1 9.6 08/20/2005 03:20:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 1.4 0.5 2.3 0.4 97 7 102 255 10.2 0 10.3 10.1 08/20/2005 03:30:00 2.4 0.4 3.4 1.5 2.4 0.4 3.8 1.5 0.7 0.5 2.3 0.4 95 5 94 255 10.3 0 10.3 10.3 08/20/2005 03:40:00 2.1 0.5 3 1.1 2.1 0.4 3 1.1 0.4 0.2 1.5 0.4 94 9 100 255 10.2 0 10.3 10.1 08/20/2005 03:50:00 1.9 0.6 3 0.4 2 0.6 3 0.4 0.5 0.3 1.9 0.4 109 15 104 255 10.1 0 10.3 10.1 08/20/2005 04:00:00 2.3 0.5 3.4 1.5 2.3 0.5 3.8 1.1 0.6 0.4 2.3 0.4 90 7 88 255 10.1 0 10.3 10.1 08/20/2005 04:10:00 2.1 0.5 3.4 1.1 2.1 0.5 3.4 1.1 0.7 0.4 1.5 0.4 80 10 79 255 10.2 0 10.6 10.1 08/20/2005 04:20:00 1.4 0.4 2.6 0.7 1.3 0.5 2.6 0.4 0.4 0.1 1.1 0.4 118 9 111 255 10.4 0 10.6 10.3 08/20/2005 04:30:00 2.4 0.3 3.4 1.5 2.3 0.4 3.4 1.5 0.7 0.5 2.3 0.4 100 8 108 255 10.2 0 10.3 10.1 08/20/2005 04:40:00 2.3 0.4 3.4 1.1 2.3 0.4 3 1.1 0.5 0.3 1.9 0.4 85 7 79 255 10.2 0 10.3 9.8 08/20/2005 04:50:00 2.1 0.4 3.4 0.7 2.1 0.4 3 1.1 0.5 0.4 1.9 0.4 111 10 111 255 9.9 0 10.1 9.8 08/20/2005 05:00:00 2.4 0.6 3.8 1.1 2.4 0.6 3.8 0.7 1 0.6 2.3 0.4 115 12 102 255 10.2 0.1 10.6 9.8 08/20/2005 05:10:00 2.8 0.4 3.8 1.9 2.8 0.3 3.8 1.9 1.4 0.6 2.6 0.4 96 7 86 255 10.9 0.3 11.4 10.6 08/20/2005 05:20:00 1.6 0.6 3.4 0.7 1.8 0.5 3.4 0.7 0.5 0.3 1.9 0.4 93 6 93 255 11.3 0 11.4 11.1 08/20/2005 05:30:00 1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.4 0 0.7 0.4 107 23 83 255 11.2 0 11.4 11.1 08/20/2005 05:40:00 1.1 0.5 2.3 0.4 1.2 0.6 2.3 0.4 0.5 0.4 1.9 0.4 130 14 137 255 11.4 0 11.7 11.4 08/20/2005 05:50:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.4 0.9 0.5 2.6 0.4 127 13 136 255 11.8 0.1 11.9 11.4 08/20/2005 06:00:00 1.7 0.4 3 0.7 1.7 0.4 2.6 0.7 0.4 0.2 1.5 0.4 83 14 49 255 12 0 12.2 11.9 08/20/2005 06:10:00 1.7 0.3 2.6 0.7 1.6 0.3 2.6 0.7 0.5 0.3 1.5 0.4 97 8 94 255 12.1 0 12.2 11.9 08/20/2005 06:20:00 2.2 0.4 3.4 1.5 2.2 0.4 3.4 1.5 1.1 0.6 2.6 0.4 81 15 30 255 12.3 0 12.5 12.2 08/20/2005 06:30:00 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 1.4 0.6 2.6 0.4 91 17 94 255 12.4 0 12.5 12.2 08/20/2005 06:40:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 0.5 0.4 2.3 0.4 66 12 58 255 12.3 0 12.2 12.2 08/20/2005 06:50:00 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.5 0.2 1.5 0.4 48 15 63 255 12.3 0 12.2 12.2 08/20/2005 07:00:00 1.5 0.5 2.6 0.4 1.4 0.5 3 0.4 0.5 0.3 1.9 0.4 59 17 62 255 12.2 0 12.2 11.9 08/20/2005 07:10:00 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 0.4 0.2 1.1 0.4 85 11 80 255 12.1 0 12.2 11.9 08/20/2005 07:20:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.4 0.2 1.5 0.4 67 11 60 255 12.1 0 12.2 11.9 08/20/2005 07:30:00 0.7 0.5 2.3 0.4 0.6 0.5 2.6 0.4 0.4 0.1 1.1 0.4 37 35 55 255 12.3 0 12.5 12.2 08/20/2005 07:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 331 0 331 255 12.7 0 12.7 12.5 08/20/2005 07:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 359 23 18 255 12.9 0.1 13.3 12.7 08/20/2005 08:00:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.5 2.3 0.4 35 13 29 255 13.4 0 13.5 13.3 08/20/2005 08:10:00 2.2 0.6 3.8 0.7 2.2 0.6 3.8 0.7 1.5 0.8 3.4 0.4 47 15 43 255 14.2 0.2 14.6 13.5 08/20/2005 08:20:00 1.9 0.5 3.4 0.4 1.9 0.6 3.4 0.4 1 0.6 2.6 0.4 46 19 30 255 14.8 0.2 15.5 14.6 08/20/2005 08:30:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.5 1.6 0.8 3.8 0.4 26 15 45 255 14.9 0 15.2 14.9 08/20/2005 08:40:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.5 2.1 0.8 4.2 0.4 43 15 33 255 14.8 0.2 15.7 14.6 08/20/2005 08:50:00 2.6 0.5 4.2 1.1 2.6 0.5 3.8 1.1 1.7 0.7 3 0.4 37 15 59 255 15.9 0.1 16.3 15.5 08/20/2005 09:00:00 2.1 0.7 3.4 0.4 2.1 0.7 3.4 0.4 1.5 0.8 3.4 0.4 35 17 43 255 15.8 0.1 16.6 15.7 08/20/2005 09:10:00 2.1 0.6 3.4 0.4 2 0.5 3.4 0.4 1.4 0.6 3 0.4 31 17 47 255 16.3 0.1 16.8 16 08/20/2005 09:20:00 2 0.7 3.8 0.4 2 0.7 3.4 0.4 1.5 0.8 3 0.4 9 14 21 255 17.2 0.3 18 16.6 08/20/2005 09:30:00 1.5 0.5 2.6 0.4 1.5 0.6 3 0.4 1.1 0.7 2.6 0.4 24 22 358 255 17.8 0 18.2 17.4 08/20/2005 09:40:00 1.6 0.4 3 0.4 1.5 0.4 2.6 0.4 1 0.5 2.6 0.4 4 16 11 255 18.3 0.2 18.8 17.7 08/20/2005 09:50:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 352 21 350 255 18.8 0 19.1 18.5 08/20/2005 10:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 31 56 68 255 18.5 0.2 19.1 18 08/20/2005 10:10:00 1.6 0.6 3 0.4 1.5 0.6 2.6 0.4 1.1 0.6 2.6 0.4 28 15 49 255 18.7 0 19.4 18.5 08/20/2005 10:20:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.5 0.4 62 23 51 255 19.2 0 19.7 18.8 08/20/2005 10:30:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 59 61 19 255 19.4 0.1 20.3 19.1 08/20/2005 10:40:00 1.5 0.5 2.3 0.4 1.3 0.6 2.6 0.4 0.8 0.5 2.3 0.4 9 17 6 255 20.2 0.1 20.8 20 08/20/2005 10:50:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.6 0.4 32 32 51 255 20.3 0 20.8 20.3 08/20/2005 11:00:00 1.7 0.7 3 0.4 1.7 0.8 3 0.4 1.2 0.8 2.6 0.4 14 21 56 255 20.4 0.3 21.1 20 08/20/2005 11:10:00 2.1 0.5 3.4 0.4 2 0.6 3 0.4 1.3 0.7 2.6 0.4 0 20 333 255 20.3 0.1 20.5 20 08/20/2005 11:20:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 1.7 0.6 3.4 0.4 2 16 10 255 20.9 0 21.1 20.5 08/20/2005 11:30:00 2 0.6 3.4 0.7 1.9 0.6 3.4 0.7 1.4 0.8 3.4 0.4 12 19 37 255 20.8 0.1 21.1 20.5 08/20/2005 11:40:00 2 0.6 3.8 0.4 1.9 0.6 3.4 0.4 1.4 0.7 3 0.4 1 20 0 255 21.3 0.1 22 20.8 08/20/2005 11:50:00 1.9 0.5 3 0.4 1.7 0.6 3.4 0.4 1.3 0.7 3 0.4 345 23 343 255 21.6 0 22 21.4 08/20/2005 12:00:00 2.7 0.5 3.8 1.5 2.5 0.6 4.2 1.1 2.1 0.7 4.2 0.4 11 23 352 255 21.9 0.2 22.6 21.4 08/20/2005 12:10:00 3.1 0.7 4.9 0.7 3 0.7 4.9 0.7 2.3 0.8 4.2 0.4 5 20 356 255 22 0 22.3 21.7 08/20/2005 12:20:00 2.8 0.7 4.2 0.4 2.7 0.6 4.2 0.7 2.1 0.8 3.4 0.4 11 18 6 255 22.1 0 22.6 22 08/20/2005 12:30:00 3 0.6 4.6 1.5 3 0.6 4.6 1.1 2.3 0.8 4.6 0.4 8 15 31 255 22.2 0 22.6 22.3 08/20/2005 12:40:00 2 0.9 4.2 0.4 2 0.9 4.2 0.4 1.4 0.9 3.8 0.4 332 39 36 255 22.4 0 22.9 22 08/20/2005 12:50:00 3 0.7 4.6 1.1 2.8 0.7 4.6 0.7 2.1 0.9 4.6 0.4 0 29 7 255 22.3 0 22.6 22 08/20/2005 13:00:00 2.6 0.6 4.6 1.1 2.4 0.6 4.6 1.1 1.8 0.7 4.2 0.4 340 23 300 255 22.3 0.3 22.9 21.7 08/20/2005 13:10:00 2.8 1 5.3 0.4 2.7 1 5.3 0.4 2.1 1.1 4.9 0.4 342 35 354 255 22.3 0.1 22.9 21.7 08/20/2005 13:20:00 2.3 0.9 4.2 0.4 2.1 0.8 4.2 0.4 1.6 0.9 3.8 0.4 320 29 344 255 22.1 0.3 22.9 21.7 08/20/2005 13:30:00 2.8 0.9 5.3 0.7 2.5 0.9 4.9 0.7 2.2 1 4.6 0.4 344 18 340 255 22.9 0.2 23.5 22.3 08/20/2005 13:40:00 2.9 1 5.3 0.4 2.8 1 5.3 0.4 1.9 0.9 5.3 0.4 349 18 3 255 22.4 0.1 22.9 22.3 08/20/2005 13:50:00 3 0.7 4.6 1.1 2.7 0.7 4.2 0.7 2.4 0.9 4.9 0.4 343 15 325 255 21.9 0.3 22.6 21.4 08/20/2005 14:00:00 3.3 0.9 5.7 1.1 3.2 0.9 5.7 1.1 2.4 1.1 5.7 0.4 350 24 352 255 22.4 0 22.9 22 08/20/2005 14:10:00 2.7 1 4.9 0.7 2.6 1 4.9 0.7 2.3 1 4.6 0.4 345 27 349 255 22.4 0 22.6 22 08/20/2005 14:20:00 2.7 0.8 4.9 1.1 2.6 0.8 4.6 0.7 2 0.9 4.2 0.4 339 27 358 255 22.4 0.2 22.9 21.7 08/20/2005 14:30:00 2.2 0.9 4.2 0.4 2.1 0.9 4.2 0.4 1.6 0.9 3.4 0.4 331 22 324 255 21.8 0.1 22 21.4 08/20/2005 14:40:00 2.8 0.7 4.6 1.1 2.6 0.7 4.2 1.1 2.1 0.8 4.6 0.4 326 21 335 255 21.8 0 22 21.7 08/20/2005 14:50:00 1.9 0.9 3.8 0.4 1.7 0.9 3.4 0.4 1.3 0.9 3.4 0.4 304 36 283 255 22.3 0 22.6 21.7 08/20/2005 15:00:00 2.7 1 5.7 0.4 2.6 1 5.7 0.4 2 0.9 4.6 0.4 304 30 306 255 22.6 0.2 23.2 22.3 08/20/2005 15:10:00 2.8 1.1 5.7 0.4 2.7 1.2 5.7 0.4 2 1.1 4.9 0.4 306 41 327 255 23.2 0 23.5 22.9 08/20/2005 15:20:00 2.8 0.9 4.9 0.4 2.7 0.9 4.9 1.1 2.2 0.9 4.9 0.4 305 22 282 255 22.8 0.1 23.2 22.6 08/20/2005 15:30:00 3 1.1 5.3 0.4 2.7 1 4.9 0.4 2.2 1.1 4.6 0.4 321 36 335 255 22.7 0 22.9 22.6 08/20/2005 15:40:00 3.2 1 5.7 1.1 3 1 5.7 1.1 2.4 1.1 5.7 0.4 321 22 297 255 22.7 0 22.9 22.6 08/20/2005 15:50:00 2.9 1 4.9 0.4 2.7 1 4.9 0.4 2.1 1.1 4.6 0.4 322 35 345 255 22.4 0 22.9 22.3 08/20/2005 16:00:00 2.8 0.6 4.2 1.1 2.5 0.6 4.2 0.7 1.9 1 3.8 0.4 338 22 336 255 23 0.2 23.5 22.3 08/20/2005 16:10:00 2.3 1.1 4.2 0.4 2.1 1.1 4.2 0.4 1.8 1 4.2 0.4 321 30 311 255 22.5 0 23.2 22.3 08/20/2005 16:20:00 2.1 0.9 4.9 0.4 1.8 0.9 4.9 0.4 1.3 0.9 4.6 0.4 327 23 343 255 21.7 0.1 22.3 21.4 08/20/2005 16:30:00 2.8 0.9 4.9 0.4 2.4 0.9 4.9 0.4 1.8 1 4.6 0.4 346 20 344 255 21.3 0.3 22 20.5 08/20/2005 16:40:00 2.9 0.5 4.6 1.9 2.5 0.6 3.8 1.1 2 0.8 3.4 0.4 333 13 330 255 20.4 0 20.8 20.3 08/20/2005 16:50:00 3 0.6 4.6 1.5 2.7 0.7 4.6 1.1 1.9 0.8 3.8 0.4 353 17 352 255 20.5 0 20.8 20.3 08/20/2005 17:00:00 3.4 1 5.3 1.1 3.3 1 5.3 1.1 1.9 1.1 4.2 0.4 14 9 9 255 20.8 0 20.8 20.5 08/20/2005 17:10:00 3.8 0.7 4.9 1.9 3.8 0.8 4.9 1.5 2.5 1.1 4.6 0.4 9 14 13 255 20.6 0 20.8 20.5 08/20/2005 17:20:00 4.1 0.7 6.1 1.9 4.1 0.7 6.1 1.9 2.9 1 5.3 0.7 11 14 22 255 20.5 0 20.8 20.5 08/20/2005 17:30:00 3.8 1 6.1 0.7 3.8 1 6.1 0.7 2.6 1.1 5.7 0.4 17 18 28 255 20.5 0 20.8 20 08/20/2005 17:40:00 4.6 1 6.8 1.9 4.6 0.9 6.8 2.3 3.4 1 5.7 1.1 29 18 32 255 19.9 0.3 20.5 19.4 08/20/2005 17:50:00 4.6 1 6.8 2.3 4.6 1 6.8 1.9 3.7 1.2 6.5 1.1 19 13 22 255 19 0.3 19.7 18.2 08/20/2005 18:00:00 4.6 0.9 6.8 2.3 4.6 0.9 7.2 2.3 3.5 1.1 6.1 1.1 14 12 13 255 18.2 0 18.8 18 08/20/2005 18:10:00 3.9 0.9 6.8 1.9 3.9 0.8 6.5 1.9 2.8 1 5.7 0.4 10 15 8 255 17.8 0 18.2 17.7 08/20/2005 18:20:00 4 1 6.8 1.9 4 1 6.5 1.5 2.8 1.2 6.5 0.4 10 13 15 255 17.6 0 17.7 17.4 08/20/2005 18:30:00 4.6 1 6.5 1.5 4.6 1 6.8 1.5 3.2 1.3 6.1 0.4 14 12 25 255 17.3 0 17.4 17.1 08/20/2005 18:40:00 3.3 0.8 5.3 0.4 3.3 0.8 5.3 0.7 2.2 1.1 4.6 0.4 4 12 35 255 17 0.1 17.1 16.8 08/20/2005 18:50:00 2.9 1.1 5.7 0.4 2.9 1.1 5.7 0.7 1.9 1 4.6 0.4 348 24 355 255 16.6 0 16.8 16.6 08/20/2005 19:00:00 2.5 0.6 4.2 1.1 2.5 0.6 4.2 1.1 1.8 0.6 3.4 0.4 225 30 197 255 16.3 0.1 16.6 16 08/20/2005 19:10:00 2 0.6 3.8 0.4 2.1 0.5 3 0.7 1.7 0.7 3 0.4 150 33 133 255 15.7 0.2 16.3 15.5 08/20/2005 19:20:00 2.5 0.5 4.2 1.1 2.5 0.5 4.2 1.1 1.5 0.6 3 0.4 84 18 53 255 15.2 0.1 15.7 15.2 08/20/2005 19:30:00 3.3 0.6 4.6 1.9 3.3 0.5 4.9 2.3 2.3 0.6 3.8 0.7 56 12 46 255 15.1 0 15.7 14.9 08/20/2005 19:40:00 2.2 0.5 3.8 1.1 2.2 0.5 3.4 1.1 0.8 0.5 2.3 0.4 28 26 30 255 14.8 0.2 15.5 14.6 08/20/2005 19:50:00 2.2 0.8 4.2 0.4 2.2 0.7 4.2 0.4 0.8 0.6 3 0.4 20 19 15 255 14.5 0 14.9 14.4 08/20/2005 20:00:00 1.7 0.8 3.4 0.4 1.8 0.7 3.4 0.4 0.5 0.3 1.9 0.4 25 22 28 255 14.4 0.1 14.9 14.1 08/20/2005 20:10:00 0.7 0.8 3.4 0.4 0.8 0.8 3.4 0.4 0.4 0.3 1.9 0.4 2 64 49 255 14.2 0.1 14.6 13.8 08/20/2005 20:20:00 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 37 76 324 255 14 0.1 14.6 13.8 08/20/2005 20:30:00 0.5 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.1 1.1 0.4 105 15 81 255 13.9 0 14.6 13.8 08/20/2005 20:40:00 1.4 0.7 3 0.4 1.5 0.6 3 0.4 0.6 0.5 2.6 0.4 85 17 82 255 13.8 0 14.4 13.5 08/20/2005 20:50:00 1.5 0.6 2.6 0.4 1.6 0.5 2.6 0.4 0.7 0.5 1.9 0.4 76 18 94 255 13.6 0.1 14.1 13.3 08/20/2005 21:00:00 2.5 0.4 3.4 1.9 2.5 0.4 3.4 1.9 1.5 0.5 2.6 0.4 99 7 102 255 13.3 0 13.8 13.3 08/20/2005 21:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.6 0.5 3 0.4 100 8 94 255 13.4 0 13.8 13.3 08/20/2005 21:20:00 2.4 1 3.8 0.4 2.4 1 3.8 0.4 1.3 0.7 3 0.4 113 22 109 255 13.4 0 13.8 13.3 08/20/2005 21:30:00 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0 0.4 0.4 132 20 133 255 13.3 0 13.8 13.3 08/20/2005 21:40:00 1.6 0.6 2.6 0.4 1.6 0.5 2.6 0.4 1 0.6 2.3 0.4 137 13 136 255 13.3 0 13.5 13 08/20/2005 21:50:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 0.7 0.5 2.3 0.4 103 17 113 255 13.3 0 13.5 13 08/20/2005 22:00:00 1.2 0.4 2.3 0.4 1.2 0.3 2.3 0.4 0.4 0.1 1.1 0.4 111 13 141 255 13.3 0 13.3 13 08/20/2005 22:10:00 1.9 0.6 3.4 0.7 1.9 0.6 3 0.7 0.9 0.6 2.6 0.4 84 12 87 255 13.2 0 13.3 13 08/20/2005 22:20:00 1.9 0.5 3.8 0.7 1.9 0.5 3.4 0.7 0.8 0.5 2.6 0.4 82 15 81 255 13.1 0 13.3 13 08/20/2005 22:30:00 1.5 0.5 2.6 0.4 1.5 0.4 2.6 0.7 0.5 0.4 1.9 0.4 99 20 97 255 13.1 0 13.3 13 08/20/2005 22:40:00 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 111 23 83 255 13.1 0 13.3 13 08/20/2005 22:50:00 1.4 0.8 2.6 0.4 1.4 0.7 2.6 0.4 0.8 0.6 2.3 0.4 110 11 99 255 13 0 13.3 13 08/20/2005 23:00:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 154 11 168 255 12.9 0 13 12.7 08/20/2005 23:10:00 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.6 0.4 1.5 0.4 139 12 137 255 12.8 0 13 12.7 08/20/2005 23:20:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 0.8 0.4 1.9 0.4 143 8 138 255 12.8 0 13 12.7 08/20/2005 23:30:00 2.4 0.5 3.4 1.5 2.4 0.5 3.4 1.5 1.7 0.5 2.6 0.4 158 5 151 255 12.8 0 13 12.7 08/20/2005 23:40:00 2.5 0.3 3.4 1.5 2.5 0.4 3.4 1.5 1.6 0.5 2.6 0.4 141 6 139 255 12.8 0 13.3 12.7 08/20/2005 23:50:00 2.7 0.5 3.4 1.1 2.7 0.5 3.4 1.5 1.7 0.6 3 0.4 128 8 138 255 12.8 0 13.3 12.7 08/21/2005 00:00:00 2.4 0.3 3.4 1.1 2.4 0.3 3.4 1.5 1.8 0.5 2.6 0.4 134 6 119 255 12.9 0 13.3 12.7 08/21/2005 00:10:00 2.1 0.5 3.4 0.4 2.2 0.5 2.6 0.7 1.1 0.5 2.3 0.4 107 28 86 255 12.9 0.1 13.3 12.7 08/21/2005 00:20:00 1.2 0.6 3 0.4 1.3 0.6 2.6 0.4 0.5 0.3 1.5 0.4 130 15 139 255 13 0.1 13.3 12.7 08/21/2005 00:30:00 1.6 0.5 2.6 0.4 1.7 0.5 2.6 0.4 0.5 0.4 1.9 0.4 111 16 134 255 13 0.1 13.3 12.7 08/21/2005 00:40:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 0.7 0.5 1.9 0.4 107 10 113 255 13.1 0 13.5 13 08/21/2005 00:50:00 2.7 0.5 4.2 1.5 2.8 0.4 4.2 1.9 1.5 0.6 3 0.4 96 9 88 255 13.1 0 13.3 13 08/21/2005 01:00:00 2.7 0.5 3.8 1.1 2.8 0.5 3.8 1.5 1.6 0.6 3 0.4 99 10 99 255 13.1 0 13.5 13 08/21/2005 01:10:00 3.3 0.7 5.3 1.5 3.4 0.7 5.3 1.9 2.3 0.9 4.2 0.4 68 18 74 255 13.1 0 13.5 13 08/21/2005 01:20:00 3.8 0.7 5.7 1.5 3.9 0.7 6.1 1.9 2.6 0.9 4.6 0.4 73 14 75 255 13.1 0 13.5 13 08/21/2005 01:30:00 3.4 0.6 4.9 1.9 3.5 0.6 4.9 1.9 2.4 0.6 4.2 0.7 71 11 74 255 13.1 0 13.5 13 08/21/2005 01:40:00 3.2 0.9 4.9 1.9 3.3 0.8 4.9 1.9 1.9 0.8 3.8 0.4 86 12 90 255 12.8 0 13.5 12.7 08/21/2005 01:50:00 2.6 0.7 4.9 1.1 2.7 0.7 4.9 1.1 1.3 0.8 3 0.4 80 16 73 255 12.7 0 13.3 12.5 08/21/2005 02:00:00 2.2 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.2 0.7 3.8 0.4 71 21 90 255 12.7 0 12.7 12.5 08/21/2005 02:10:00 2.5 0.8 4.6 0.4 2.6 0.8 4.6 0.4 1.4 0.9 3 0.4 60 16 81 255 12.8 0 13 12.7 08/21/2005 02:20:00 4.8 1.7 9.5 2.3 4.8 1.6 9.9 1.9 3.7 1.5 9.9 1.1 43 17 31 255 13 0.1 13.3 12.7 08/21/2005 02:30:00 6 1.3 9.9 3.4 5.9 1.2 9.1 3.8 4.7 1.3 9.1 1.5 35 15 75 255 13.3 0 13.5 13 08/21/2005 02:40:00 5.8 1.4 8.8 3 5.8 1.3 8.8 3 4.7 1.4 8.4 1.9 46 17 22 255 13.3 0 13.5 13.3 08/21/2005 02:50:00 4.8 1 8 3 4.8 1 8 3 3.8 1.1 6.8 1.5 35 18 21 255 13.3 0 13.3 13 08/21/2005 03:00:00 4.7 1.1 7.6 1.9 4.8 1 7.6 2.3 3.7 1.1 6.1 1.1 53 18 45 255 13.1 0 13.3 12.7 08/21/2005 03:10:00 4.5 0.9 6.5 2.3 4.6 0.9 6.5 2.3 3.5 1.1 6.5 0.7 27 11 32 255 12.9 0.2 13.3 12.5 08/21/2005 03:20:00 3.7 0.7 4.9 1.5 3.8 0.7 5.7 1.9 2.6 0.8 4.9 0.4 70 18 87 255 12.6 0.1 12.7 12.5 08/21/2005 03:30:00 4.1 0.8 5.7 1.5 4.2 0.7 6.1 1.9 2.9 0.8 5.3 0.4 66 15 29 255 12.5 0 12.7 12.5 08/21/2005 03:40:00 3.6 0.8 4.9 0.7 3.7 0.7 5.3 1.5 2.6 0.9 4.2 0.4 68 15 45 255 12.7 0 12.7 12.5 08/21/2005 03:50:00 2.9 1.2 6.1 0.4 2.9 1.2 6.5 0.4 1.7 1.2 5.3 0.4 57 22 40 255 12.5 0 12.7 12.2 08/21/2005 04:00:00 3 0.8 5.3 1.1 3.2 0.8 5.3 1.1 1.9 0.9 4.6 0.4 69 15 85 255 12.3 0 12.5 12.2 08/21/2005 04:10:00 2.7 0.6 4.2 1.5 2.8 0.5 4.2 1.5 1.5 0.7 3.4 0.4 71 14 70 255 12.2 0 12.5 11.9 08/21/2005 04:20:00 2.5 1 4.6 0.4 2.6 0.9 4.2 0.4 1.5 0.9 3.8 0.4 83 17 65 255 11.9 0 11.9 11.9 08/21/2005 04:30:00 3.1 0.8 4.9 0.7 3.2 0.7 4.9 1.1 1.8 0.9 4.2 0.4 93 18 88 255 12.3 0 12.5 11.9 08/21/2005 04:40:00 1.7 1 5.3 0.4 2 0.9 4.9 0.4 0.8 0.9 4.9 0.4 82 22 72 255 12.3 0 12.5 11.9 08/21/2005 04:50:00 2.1 0.9 3.4 0.4 2.2 0.8 3.8 0.4 1.5 0.9 3.8 0.4 123 22 134 255 11.9 0 12.2 11.7 08/21/2005 05:00:00 1.1 0.5 2.6 0.4 1.4 0.4 2.6 0.4 0.6 0.4 1.9 0.4 151 21 116 255 12 0 12.2 11.9 08/21/2005 05:10:00 1.3 1 3.8 0.4 1.4 1 3.8 0.4 0.7 0.6 2.6 0.4 103 36 344 255 11.8 0 11.9 11.7 08/21/2005 05:20:00 1.8 0.7 3.8 0.4 1.9 0.7 3.8 0.4 0.6 0.5 2.3 0.4 39 22 7 255 11.7 0 11.9 11.7 08/21/2005 05:30:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.4 0.1 1.1 0.4 62 18 55 255 11.7 0 11.7 11.7 08/21/2005 05:40:00 0.8 0.7 3.8 0.4 0.8 0.7 3.8 0.4 0.4 0.2 1.9 0.4 71 22 111 255 11.7 0 11.7 11.7 08/21/2005 05:50:00 2.3 0.5 3 0.7 2.2 0.5 3 0.7 1.3 0.7 2.6 0.4 116 15 131 255 11.7 0 11.7 11.7 08/21/2005 06:00:00 2.3 0.4 3.4 0.7 2.3 0.4 3 1.1 1.3 0.6 2.6 0.4 119 12 126 255 11.7 0 11.9 11.7 08/21/2005 06:10:00 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.9 1.9 0.7 3.4 0.4 132 9 144 255 11.7 0 11.9 11.7 08/21/2005 06:20:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 1.1 1.7 0.7 3 0.4 131 12 127 255 11.8 0 11.9 11.7 08/21/2005 06:30:00 2.1 0.7 3.4 0.4 2.3 0.6 3.8 0.4 1.3 0.8 3.4 0.4 127 13 134 255 11.8 0 11.9 11.7 08/21/2005 06:40:00 1.9 0.8 3.8 0.4 2.4 0.6 3.8 0.7 1.2 0.8 3 0.4 111 13 106 255 11.7 0 11.9 11.7 08/21/2005 06:50:00 2.7 0.6 4.2 1.1 2.9 0.5 4.2 1.5 1.6 0.8 3 0.4 96 11 114 255 11.7 0 11.9 11.7 08/21/2005 07:00:00 1.3 0.7 3 0.4 1.6 0.7 3 0.4 0.6 0.5 2.3 0.4 114 17 103 255 11.7 0 11.9 11.7 08/21/2005 07:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 177 16 255 255 11.7 0 11.7 11.7 08/21/2005 07:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 134 29 255 255 11.7 0 11.7 11.7 08/21/2005 07:30:00 0.9 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.4 0.2 1.1 0.4 202 29 201 255 11.7 0 11.7 11.7 08/21/2005 07:40:00 1.8 0.7 3.4 0.4 2 0.5 3.4 0.7 1 0.6 2.6 0.4 174 14 153 255 11.7 0 11.7 11.7 08/21/2005 07:50:00 2.8 0.6 3.8 1.5 2.8 0.5 3.8 1.5 1.7 0.7 3 0.4 151 12 168 255 11.7 0 11.7 11.7 08/21/2005 08:00:00 2.3 0.5 3.4 0.7 2.4 0.5 3.8 1.1 1.5 0.8 2.6 0.4 155 15 138 255 11.7 0 11.9 11.7 08/21/2005 08:10:00 3.2 0.5 4.6 1.5 3.3 0.5 4.6 1.9 2.2 0.7 3.8 0.4 122 13 121 255 11.7 0 11.9 11.7 08/21/2005 08:20:00 3.1 0.7 4.6 0.7 3.3 0.6 4.6 1.5 2.1 0.8 3.8 0.4 116 12 105 255 11.7 0 11.9 11.7 08/21/2005 08:30:00 3.2 0.8 4.9 0.7 3.3 0.7 4.9 1.1 2.1 0.9 4.6 0.4 125 13 116 255 11.7 0 11.9 11.7 08/21/2005 08:40:00 4.4 0.6 5.7 2.3 4.4 0.5 5.7 3 3.2 0.7 4.6 0.7 106 11 95 255 11.7 0 11.7 11.7 08/21/2005 08:50:00 3.8 0.7 5.7 1.5 3.9 0.6 5.3 2.3 2.6 0.8 4.6 0.4 103 12 92 255 11.7 0 11.9 11.7 08/21/2005 09:00:00 2.8 0.7 4.9 1.1 2.9 0.8 4.9 1.1 1.6 0.8 3.4 0.4 106 14 95 255 11.8 0 11.9 11.7 08/21/2005 09:10:00 2.3 0.5 3.8 0.7 2.3 0.5 3.8 0.7 1.4 0.6 2.6 0.4 131 14 119 255 11.9 0 11.9 11.7 08/21/2005 09:20:00 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.9 2.1 0.7 3.8 0.4 140 10 154 255 11.8 0 11.9 11.7 08/21/2005 09:30:00 3 0.5 4.2 1.5 3 0.5 4.2 1.9 2 0.7 3.8 0.4 145 11 140 255 11.9 0 11.9 11.7 08/21/2005 09:40:00 2.8 0.6 4.2 1.1 2.8 0.5 4.2 1.5 1.8 0.7 3.4 0.4 140 9 144 255 12 0 12.2 11.9 08/21/2005 09:50:00 1.8 0.6 3.4 0.4 2 0.5 3.4 1.1 1 0.6 2.6 0.4 143 16 134 255 12.1 0 12.2 11.9 08/21/2005 10:00:00 1.7 0.6 3 0.4 1.9 0.6 3 0.4 0.8 0.6 2.3 0.4 139 14 146 255 12.1 0 12.2 11.9 08/21/2005 10:10:00 2.1 0.6 4.2 1.1 2.2 0.6 4.6 0.7 1.4 0.7 3.4 0.4 131 13 108 255 12.1 0 12.2 11.9 08/21/2005 10:20:00 1.6 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.2 0.7 3 0.4 167 24 166 255 12.2 0 12.2 11.9 08/21/2005 10:30:00 2.6 0.6 4.6 1.1 2.5 0.6 4.2 1.1 1.7 0.9 3.4 0.4 123 30 119 255 12.2 0 12.2 12.2 08/21/2005 10:40:00 3 1 5.7 0.4 3 0.9 5.7 0.7 2 0.9 5.7 0.4 95 19 86 255 12.1 0 12.2 11.9 08/21/2005 10:50:00 2.3 0.7 4.2 0.4 2.3 0.6 4.2 0.7 1.3 0.8 3.4 0.4 90 15 58 255 12 0 12.2 11.9 08/21/2005 11:00:00 2.8 0.7 4.6 0.7 2.8 0.8 4.6 0.7 1.6 0.8 3.4 0.4 94 17 91 255 12 0 12.2 11.9 08/21/2005 11:10:00 2.8 0.7 4.9 1.1 2.9 0.6 4.9 1.1 1.6 0.8 3.4 0.4 101 16 92 255 12 0 11.9 11.9 08/21/2005 11:20:00 2.4 0.5 3.8 0.7 2.5 0.5 3.8 1.1 1.3 0.7 3 0.4 94 13 100 255 12.1 0 12.2 11.9 08/21/2005 11:30:00 3 0.8 4.9 1.5 3.1 0.7 4.9 1.5 1.9 1 3.8 0.4 87 15 66 255 12.3 0 12.2 12.2 08/21/2005 11:40:00 2.7 0.5 3.4 1.1 2.8 0.5 3.8 1.1 1.7 0.7 3 0.4 106 9 104 255 12.1 0 12.2 11.9 08/21/2005 11:50:00 2.7 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.5 0.7 3 0.4 102 14 90 255 12.2 0 12.2 12.2 08/21/2005 12:00:00 2.4 0.6 3.8 0.4 2.6 0.6 4.2 0.7 1.6 0.6 3 0.4 97 11 97 255 12.4 0 12.5 12.2 08/21/2005 12:10:00 3.2 0.6 4.9 1.5 3.3 0.6 4.9 1.5 2.1 0.7 3.8 0.4 88 12 83 255 12.5 0 12.7 12.5 08/21/2005 12:20:00 2.9 0.7 4.9 1.1 3 0.6 4.6 1.9 2 0.9 4.6 0.4 98 13 100 255 12.8 0 12.7 12.7 08/21/2005 12:30:00 3.7 0.8 5.3 1.5 3.7 0.8 5.7 1.9 2.7 1 4.9 0.4 86 11 80 255 13 0 13 12.7 08/21/2005 12:40:00 4.3 0.8 6.5 2.6 4.3 0.8 6.8 2.3 3.1 1.1 5.7 0.4 89 13 85 255 12.9 0 13 12.7 08/21/2005 12:50:00 2.2 1 4.6 0.4 2.5 0.9 4.6 0.4 1.5 1 3.8 0.4 162 47 115 255 12.8 0 13 12.7 08/21/2005 13:00:00 3.3 0.8 6.5 1.5 3.6 0.8 6.1 1.9 2.7 1 5.7 0.4 156 16 152 255 12.9 0 13 12.7 08/21/2005 13:10:00 3.8 1.4 8 0.7 4.1 1.4 8 1.1 3.1 1.5 7.2 0.4 171 22 153 255 12.8 0 13.3 12.5 08/21/2005 13:20:00 4 1 6.5 1.5 4.4 1.1 7.6 1.5 3.1 1.2 6.1 0.7 176 20 187 255 12.3 0.1 12.7 11.9 08/21/2005 13:30:00 1.9 1 5.3 0.4 2.1 0.9 4.9 0.7 1.1 1 4.6 0.4 114 45 81 255 11.7 0 12.2 11.4 08/21/2005 13:40:00 2.9 0.7 4.2 1.1 3 0.7 4.2 1.1 2.1 0.8 3.8 0.4 57 12 69 255 11.5 0 11.7 11.4 08/21/2005 13:50:00 2.6 0.6 3.8 0.7 2.7 0.6 4.2 0.7 1.7 0.7 3 0.4 43 13 77 255 11.6 0 11.7 11.4 08/21/2005 14:00:00 2.6 0.5 4.2 1.1 2.6 0.5 3.8 1.1 1.3 0.7 3 0.4 63 16 91 255 11.7 0 11.7 11.7 08/21/2005 14:10:00 1.4 0.8 3.4 0.4 1.4 0.8 3.8 0.4 0.6 0.5 2.6 0.4 37 29 59 255 11.7 0 11.7 11.7 08/21/2005 14:20:00 0.8 0.8 2.6 0.4 0.7 0.7 2.6 0.4 0.5 0.4 2.6 0.4 353 17 350 255 11.7 0 11.9 11.7 08/21/2005 14:30:00 2.6 0.5 3.8 1.5 2.5 0.6 3.8 0.7 1 0.7 3 0.4 332 21 345 255 11.7 0 11.9 11.7 08/21/2005 14:40:00 1.4 0.8 3.8 0.4 1.3 0.9 3.4 0.4 0.5 0.4 2.6 0.4 2 20 340 255 11.7 0 11.7 11.7 08/21/2005 14:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 49 2 58 255 11.7 0 11.7 11.7 08/21/2005 15:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 29 49 255 11.7 0 11.9 11.7 08/21/2005 15:10:00 1.7 0.9 3.8 0.4 1.7 1 3.8 0.4 1.1 0.8 3 0.4 108 10 93 255 11.9 0 11.9 11.7 08/21/2005 15:20:00 2.7 0.7 3.8 1.1 2.7 0.6 4.2 1.1 1.4 0.7 3 0.4 101 30 94 255 12.1 0 12.2 11.9 08/21/2005 15:30:00 1.5 0.6 3 0.4 1.7 0.5 2.6 0.4 0.9 0.5 2.3 0.4 166 18 192 255 12.1 0 12.2 11.9 08/21/2005 15:40:00 2 0.4 2.6 1.1 2.4 0.3 3 1.5 1.3 0.6 2.6 0.4 182 12 192 255 12.3 0 12.2 12.2 08/21/2005 15:50:00 1.4 0.5 2.6 0.4 1.5 0.6 3 0.4 0.6 0.4 1.9 0.4 167 12 158 255 12.3 0 12.5 12.2 08/21/2005 16:00:00 1.8 0.4 3 1.1 1.7 0.4 3 0.7 0.7 0.5 2.3 0.4 136 20 133 255 12.6 0 12.7 12.5 08/21/2005 16:10:00 2.2 0.5 3.4 0.7 2.1 0.5 3.4 0.4 1.2 0.6 2.6 0.4 94 11 101 255 12.8 0 12.7 12.7 08/21/2005 16:20:00 1.5 0.9 3.4 0.4 1.4 0.8 3 0.4 0.7 0.6 2.6 0.4 96 29 103 255 12.9 0 13 12.7 08/21/2005 16:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 222 41 243 255 13.2 0 13.3 13 08/21/2005 16:40:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.9 0.4 216 28 202 255 13.5 0 13.5 13.3 08/21/2005 16:50:00 0.7 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 122 9 146 255 13.7 0 14.4 13.5 08/21/2005 17:00:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 103 36 79 255 14.1 0.1 14.6 13.8 08/21/2005 17:10:00 1.6 0.5 3 0.4 1.2 0.6 3 0.4 1 0.6 3 0.4 114 16 94 255 14.2 0 14.6 14.4 08/21/2005 17:20:00 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.6 0.4 121 28 107 255 14.3 0 14.9 14.4 08/21/2005 17:30:00 1.2 0.5 2.6 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 66 45 54 255 14.4 0 14.9 14.4 08/21/2005 17:40:00 3 0.9 5.3 1.1 3 1 5.7 0.4 2.1 1 4.6 0.4 50 21 83 255 14.3 0.1 14.9 14.1 08/21/2005 17:50:00 2.5 1.3 4.9 0.4 2.6 1.4 5.3 0.4 2.2 1.1 4.9 0.4 95 51 37 255 13.8 0 14.4 13.3 08/21/2005 18:00:00 2.9 0.5 4.2 1.5 3.1 0.4 4.2 1.9 2.2 0.6 3.8 0.7 142 21 144 255 13.3 0 13.5 13 08/21/2005 18:10:00 2.3 0.4 3 1.1 2.3 0.4 3.4 1.5 1.3 0.5 2.3 0.4 111 12 119 255 13.1 0 13.5 13 08/21/2005 18:20:00 2.5 0.7 4.2 1.1 2.6 0.7 4.2 1.1 1.7 0.8 3.8 0.4 106 11 126 255 13 0 13.5 12.7 08/21/2005 18:30:00 1.5 0.4 2.6 0.7 1.3 0.4 2.6 0.4 0.6 0.4 1.9 0.4 125 15 99 255 12.9 0.1 13.5 12.7 08/21/2005 18:40:00 1.9 0.5 2.6 0.7 1.9 0.4 2.6 1.1 1 0.5 1.9 0.4 156 8 167 255 12.5 0 13 12.5 08/21/2005 18:50:00 0.7 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0 0.7 0.4 146 0 146 255 12.5 0 12.7 12.5 08/21/2005 19:00:00 1.9 1.2 4.9 0.4 1.7 1.3 4.9 0.4 0.7 0.7 3.4 0.4 5 27 6 255 12.4 0 12.5 12.2 08/21/2005 19:10:00 3.8 0.6 5.3 2.3 3.8 0.7 5.3 1.9 1.8 0.9 4.2 0.4 15 11 32 255 12.5 0 12.5 12.5 08/21/2005 19:20:00 2.8 0.9 4.9 0.7 2.7 1 4.9 0.7 1.2 0.9 3.4 0.4 7 15 354 255 12.6 0 12.7 12.5 08/21/2005 19:30:00 1.7 0.8 3.8 0.4 1.7 0.9 3.8 0.4 0.6 0.5 2.3 0.4 1 13 334 255 12.7 0 12.7 12.5 08/21/2005 19:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 43 43 73 255 12.7 0 12.7 12.5 08/21/2005 19:50:00 1.3 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.5 0.3 1.5 0.4 100 6 97 255 12.1 0.1 12.5 11.7 08/21/2005 20:00:00 1.4 0.2 2.3 0.7 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 109 9 104 255 11.5 0.1 11.9 11.4 08/21/2005 20:10:00 1.6 0.6 3 0.7 1.5 0.6 3 0.4 0.8 0.8 2.6 0.4 133 12 146 255 11 0 11.4 10.9 08/21/2005 20:20:00 3 0.5 3.8 1.5 2.9 0.5 3.8 1.5 1.9 0.7 3 0.4 146 5 158 255 10.7 0 10.9 10.6 08/21/2005 20:30:00 1.8 0.3 2.6 0.7 1.8 0.3 2.6 0.7 0.6 0.3 1.5 0.4 140 7 148 255 10.6 0 10.9 10.3 08/21/2005 20:40:00 2.2 0.5 3.4 0.7 2.1 0.6 3.4 0.7 0.8 0.5 2.3 0.4 122 7 118 255 10.2 0 10.6 9.8 08/21/2005 20:50:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.1 1.7 0.5 3 0.4 120 8 118 255 9.8 0.1 10.1 9.6 08/21/2005 21:00:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1 0.5 2.6 0.4 117 11 131 255 9.6 0 9.8 9.6 08/21/2005 21:10:00 2.1 0.4 3 1.1 2.1 0.5 3 1.1 1.1 0.6 2.6 0.4 125 11 112 255 9.4 0 9.6 9.3 08/21/2005 21:20:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 134 4 131 255 9.4 0 9.6 9 08/21/2005 21:30:00 1.5 0.4 2.6 0.7 1.1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 130 8 131 255 9.4 0 9.6 9.3 08/21/2005 21:40:00 1.5 0.9 3.4 0.4 1.2 1.1 3.4 0.4 0.8 0.8 2.6 0.4 122 18 134 255 9.4 0 9.6 9.3 08/21/2005 21:50:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.7 0.5 3 0.7 126 9 136 255 9.2 0 9.6 9 08/21/2005 22:00:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.5 1.8 0.4 2.6 0.7 123 9 122 255 9.5 0 9.6 9.6 08/21/2005 22:10:00 2.3 0.7 3.4 0.7 2.1 0.8 3.4 0.4 1.2 0.6 2.6 0.4 116 12 116 255 9.6 0 9.6 9.6 08/21/2005 22:20:00 1.2 0.7 3 0.4 0.9 0.7 2.6 0.4 0.4 0.1 0.7 0.4 96 18 113 255 9.4 0 9.6 9.3 08/21/2005 22:30:00 1.3 0.8 2.6 0.4 1.1 0.7 2.6 0.4 0.4 0.2 1.5 0.4 61 14 61 255 9.2 0 9.3 9 08/21/2005 22:40:00 1.5 0.4 2.3 0.7 1.2 0.5 2.3 0.4 0.4 0.1 1.1 0.4 34 4 50 255 9 0 9 9 08/21/2005 22:50:00 1.7 0.3 2.6 1.1 1.5 0.3 2.6 0.7 0.5 0.3 1.9 0.4 60 11 66 255 9.1 0 9.3 9 08/21/2005 23:00:00 2.2 0.3 3 1.5 2.1 0.4 3 1.1 1.2 0.4 2.3 0.4 65 7 46 255 9.2 0 9.3 9 08/21/2005 23:10:00 2.5 0.3 3.4 1.9 2.4 0.3 3.4 1.5 1.4 0.4 2.6 0.4 75 8 79 255 9.4 0 9.3 9.3 08/21/2005 23:20:00 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.7 0.9 0.5 2.3 0.4 80 9 99 255 9.4 0 9.3 9.3 08/21/2005 23:30:00 1.6 0.4 2.6 0.4 1.5 0.4 2.6 0.4 0.8 0.4 1.5 0.4 71 10 87 255 9.5 0 9.6 9.3 08/21/2005 23:40:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 0.7 0.5 2.3 0.4 61 9 40 255 9.6 0 9.6 9.6 08/21/2005 23:50:00 1.7 0.4 3 0.7 1.5 0.4 2.6 0.7 0.7 0.5 2.3 0.4 67 9 58 255 9.7 0 9.8 9.6 08/22/2005 00:00:00 2.5 0.3 3.4 1.5 2.4 0.4 3 1.1 1.3 0.5 2.3 0.4 75 9 68 255 9.8 0 10.3 9.6 08/22/2005 00:10:00 2.5 0.4 3.8 1.5 2.4 0.5 3.4 1.1 1.2 0.5 2.3 0.4 83 10 71 255 9.8 0 9.8 9.6 08/22/2005 00:20:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.3 0.6 2.6 0.4 73 14 60 255 9.7 0 9.8 9.6 08/22/2005 00:30:00 2.3 0.5 3.4 1.1 2.2 0.5 3 1.1 1.1 0.6 2.6 0.4 70 11 61 255 9.6 0 9.8 9.6 08/22/2005 00:40:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.1 1.5 0.5 2.6 0.4 87 11 67 255 9.6 0 9.8 9.6 08/22/2005 00:50:00 2.4 0.6 3.8 1.1 2.3 0.6 3.8 0.7 1.7 0.7 3 0.4 119 15 118 255 9.6 0 9.6 9.6 08/22/2005 01:00:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.5 1.3 0.6 3 0.4 115 12 130 255 9.5 0 9.6 9.3 08/22/2005 01:10:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 1.1 0.5 2.6 0.4 109 9 103 255 9.3 0 9.6 9 08/22/2005 01:20:00 2.4 0.4 3 1.5 2.3 0.4 3 1.1 1.2 0.5 2.3 0.4 98 6 104 255 9.1 0 9.3 9 08/22/2005 01:30:00 1.9 0.5 3 0.7 1.7 0.5 3 0.4 0.7 0.4 1.9 0.4 103 11 88 255 9 0 9.3 9 08/22/2005 01:40:00 2.1 0.7 3.4 0.7 1.9 0.8 3.4 0.4 1.1 0.7 2.6 0.4 109 12 96 255 8.9 0 9 8.8 08/22/2005 01:50:00 2.8 0.5 3.8 1.1 2.8 0.5 3.8 1.5 1.8 0.6 3 0.4 102 8 100 255 8.8 0 9 8.8 08/22/2005 02:00:00 1.9 0.6 3 0.7 1.8 0.6 3.4 0.4 1 0.6 2.6 0.4 104 12 99 255 8.7 0 8.8 8.5 08/22/2005 02:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 106 11 101 255 8.7 0 8.8 8.8 08/22/2005 02:20:00 1.4 0.6 3 0.4 1.2 0.6 3 0.4 0.7 0.6 2.6 0.4 124 16 133 255 8.7 0 8.8 8.5 08/22/2005 02:30:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1 0.5 2.3 0.4 127 13 119 255 8.9 0 9 8.8 08/22/2005 02:40:00 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 0.7 0.4 1.9 0.4 125 14 110 255 9 0 9 9 08/22/2005 02:50:00 1.9 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1.2 0.5 2.6 0.4 128 13 118 255 9 0 9 9 08/22/2005 03:00:00 2.3 0.4 3 1.1 2.1 0.4 3 0.7 1.5 0.5 2.6 0.4 135 10 133 255 9 0 9 9 08/22/2005 03:10:00 2.3 0.6 3.8 0.7 2.1 0.7 3.4 0.4 1.5 0.6 2.6 0.4 124 13 136 255 9 0 9.3 9 08/22/2005 03:20:00 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.4 1.3 0.6 2.6 0.4 115 12 112 255 9 0 9.3 9 08/22/2005 03:30:00 2.7 0.5 4.2 1.1 2.6 0.5 4.2 1.1 1.5 0.6 3 0.4 115 10 122 255 8.9 0 9 8.8 08/22/2005 03:40:00 3.1 0.6 4.6 1.5 3 0.6 4.6 1.5 2 0.7 3.8 0.4 114 14 107 255 8.5 0.1 8.8 8.5 08/22/2005 03:50:00 2.7 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.7 0.6 3 0.4 116 13 121 255 8.5 0 8.5 8.5 08/22/2005 04:00:00 3.3 0.7 4.9 1.5 3.2 0.7 4.9 1.5 2.2 0.6 3.8 0.4 118 13 115 255 8.3 0 8.5 8 08/22/2005 04:10:00 2.5 0.7 4.9 0.7 2.3 0.8 4.6 0.4 1.4 0.8 3 0.4 100 16 116 255 8.2 0 8.5 8 08/22/2005 04:20:00 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 105 13 104 255 7.8 0 8.3 7.5 08/22/2005 04:30:00 2.4 0.4 3.4 1.1 2.2 0.4 3 0.7 1.1 0.5 2.3 0.4 106 9 106 255 7.3 0 7.5 7.3 08/22/2005 04:40:00 2.9 0.7 4.9 1.5 2.8 0.7 4.6 1.1 1.8 0.8 3.8 0.4 109 11 98 255 6.9 0.1 7.3 6.7 08/22/2005 04:50:00 3.6 0.5 4.9 2.3 3.5 0.5 4.9 2.3 2.3 0.6 3.8 0.4 106 11 136 255 7.2 0 7.3 7 08/22/2005 05:00:00 3.6 0.8 5.3 1.5 3.4 0.9 4.9 0.7 2.2 0.9 4.2 0.4 114 16 106 255 7.4 0.1 7.8 7.3 08/22/2005 05:10:00 3.1 0.6 4.9 1.5 3.1 0.6 4.6 1.1 2.2 0.6 4.2 0.7 111 13 99 255 7.8 0 7.8 7.5 08/22/2005 05:20:00 3.2 0.6 4.6 1.1 3.1 0.6 4.6 1.1 2 0.8 3.8 0.4 110 12 119 255 7.7 0 7.8 7.5 08/22/2005 05:30:00 3.3 0.5 4.6 1.9 3.2 0.5 4.2 1.9 2.1 0.6 3.8 0.7 108 9 126 255 7.6 0 7.8 7.5 08/22/2005 05:40:00 3.7 0.5 4.9 2.3 3.6 0.5 4.9 2.3 2.6 0.6 4.6 1.1 105 9 92 255 7.4 0 7.5 7.3 08/22/2005 05:50:00 3.2 0.7 4.6 1.1 3.1 0.7 4.6 1.1 2 0.7 3.8 0.4 110 12 117 255 7.3 0 7.5 7.3 08/22/2005 06:00:00 2.4 0.6 4.6 0.7 2.3 0.7 4.2 0.7 1.5 0.7 3.4 0.4 118 15 113 255 7.4 0 7.8 7.3 08/22/2005 06:10:00 2 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.1 0.6 2.6 0.4 107 17 94 255 7.8 0 7.8 7.5 08/22/2005 06:20:00 3.3 0.6 4.6 1.5 3.1 0.6 4.6 1.1 2.2 0.7 4.2 0.7 112 11 112 255 7.8 0 8 7.5 08/22/2005 06:30:00 2.6 0.7 4.6 1.1 2.4 0.8 4.6 0.4 1.5 0.8 3.8 0.4 110 15 113 255 8.1 0 8.3 7.8 08/22/2005 06:40:00 3 0.7 4.6 1.1 2.9 0.7 4.6 0.7 2.2 0.7 4.2 0.7 112 13 109 255 8.3 0 8.5 8.3 08/22/2005 06:50:00 3.1 0.8 4.9 0.7 3 0.9 5.3 0.4 2.2 0.7 4.2 0.7 114 16 106 255 8.9 0.3 9.6 8.5 08/22/2005 07:00:00 2 0.8 4.2 0.4 1.7 0.8 3.8 0.4 1.3 0.8 3.4 0.4 112 17 100 255 10 0.2 10.6 9.6 08/22/2005 07:10:00 2 1 4.6 0.4 1.9 1 4.2 0.4 1.4 0.8 3.8 0.4 115 17 104 255 10.5 0.1 10.9 10.3 08/22/2005 07:20:00 2.2 1 4.2 0.4 2.1 1 4.2 0.4 1.8 1 3.8 0.4 110 18 113 255 11.1 0 11.4 10.9 08/22/2005 07:30:00 2.3 0.7 3.8 0.7 2.2 0.7 3.8 0.4 1.7 0.7 3.4 0.4 104 17 91 255 11.6 0.2 11.9 11.1 08/22/2005 07:40:00 2.7 0.6 4.2 1.1 2.7 0.6 4.2 0.7 2.1 0.7 3.4 0.4 102 15 113 255 12 0 12.2 11.9 08/22/2005 07:50:00 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.3 0.6 4.2 0.4 100 13 99 255 12.3 0.2 12.7 11.9 08/22/2005 08:00:00 2.6 0.6 3.8 1.1 2.5 0.6 3.4 0.4 2.1 0.6 3.4 0.4 105 14 101 255 12.9 0.1 13.5 12.7 08/22/2005 08:10:00 2.8 0.5 4.6 0.7 2.7 0.5 4.6 1.5 2.4 0.6 3.8 0.4 101 13 96 255 13.4 0 13.8 13.3 08/22/2005 08:20:00 2.6 0.9 4.2 0.4 2.6 0.8 4.2 0.4 2.3 0.8 4.2 0.4 77 12 70 255 13.4 0 13.8 13.3 08/22/2005 08:30:00 2.7 0.7 4.2 0.4 2.7 0.7 4.9 0.4 2.2 0.9 4.2 0.4 82 21 85 255 13.7 0.2 14.6 13.3 08/22/2005 08:40:00 2 0.7 3.4 0.4 2.1 0.7 3.4 0.4 1.6 0.6 3 0.4 71 28 42 255 14.4 0.2 14.9 14.1 08/22/2005 08:50:00 2.3 0.6 3.8 0.7 2.2 0.7 3.8 0.4 1.9 0.8 3.8 0.4 39 13 23 255 14.6 0.1 15.2 14.4 08/22/2005 09:00:00 1.6 0.8 3.8 0.4 1.8 0.8 3.4 0.4 1.4 0.8 3 0.4 69 20 87 255 15 0 15.5 14.6 08/22/2005 09:10:00 1.9 0.7 3.4 0.4 2 0.7 3.4 0.4 1.6 0.8 3.4 0.4 68 18 75 255 15 0 15.5 14.9 08/22/2005 09:20:00 2 0.7 3.8 0.4 2 0.7 3.8 0.4 1.7 0.7 3.4 0.4 57 17 43 255 15.1 0 15.7 14.9 08/22/2005 09:30:00 2.3 0.6 3.4 0.4 2.3 0.7 3.4 0.7 1.8 0.7 3.4 0.4 74 21 79 255 15.6 0 16.3 15.5 08/22/2005 09:40:00 1.7 0.6 3 0.4 1.8 0.6 3 0.4 1.3 0.6 3 0.4 73 20 37 255 15.6 0 16.3 15.5 08/22/2005 09:50:00 1.6 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.1 0.6 3.4 0.4 49 27 64 255 16.1 0.1 16.6 15.7 08/22/2005 10:00:00 1.8 0.5 3.4 0.4 1.8 0.6 3.8 0.4 1.5 0.5 3.4 0.4 46 27 68 255 16.4 0 16.8 16.3 08/22/2005 10:10:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 24 10 30 255 17 0.2 17.4 16.6 08/22/2005 10:20:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 1.2 0.6 2.6 0.4 22 14 27 255 17.4 0.1 18 17.1 08/22/2005 10:30:00 1.6 0.5 3 0.4 1.7 0.6 3 0.4 1.4 0.6 3 0.4 37 18 32 255 17.8 0 18.2 17.4 08/22/2005 10:40:00 1.5 0.6 2.6 0.4 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 9 19 11 255 18 0.1 18.5 17.7 08/22/2005 10:50:00 1.9 0.6 4.9 0.7 2 0.6 4.9 0.7 1.4 0.6 3 0.4 356 17 354 255 18.4 0 18.8 18.2 08/22/2005 11:00:00 2.3 0.5 4.2 1.1 2.3 0.5 3.8 0.7 2.1 0.6 3.4 0.7 30 18 37 255 18 0.2 18.8 17.4 08/22/2005 11:10:00 1.8 0.5 3 0.4 2 0.5 3 0.4 1.7 0.5 2.6 0.4 20 17 37 255 18.2 0.2 18.8 18 08/22/2005 11:20:00 1.3 0.7 3 0.4 1.4 0.7 3 0.4 1.4 0.6 3 0.4 38 26 36 255 18.4 0.1 18.8 18.2 08/22/2005 11:30:00 2.1 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.7 0.7 3.8 0.4 22 21 26 255 18.6 0 19.1 18.2 08/22/2005 11:40:00 2.2 0.7 3.8 0.4 2.2 0.7 3.8 0.4 1.9 0.6 3.4 0.4 31 20 25 255 18.7 0 19.1 18.5 08/22/2005 11:50:00 2.2 0.6 3.8 0.4 2.3 0.6 3.8 0.4 1.9 0.6 3.4 0.4 20 15 9 255 19 0 19.4 18.8 08/22/2005 12:00:00 1.8 0.6 3.4 0.4 1.9 0.6 3.8 0.7 1.6 0.4 3 0.7 22 20 22 255 18.9 0 19.4 18.8 08/22/2005 12:10:00 2.8 0.6 4.2 1.5 2.9 0.5 4.2 1.9 2.4 0.6 3.8 0.7 18 10 16 255 18.7 0.2 19.4 18.2 08/22/2005 12:20:00 2.2 0.7 3.4 0.4 2.3 0.8 3.8 0.4 1.9 0.9 3.8 0.4 9 14 15 255 18.5 0.1 18.8 18.2 08/22/2005 12:30:00 1.8 0.6 3.4 0.4 1.9 0.6 3.4 0.7 1.2 0.7 3.4 0.4 14 29 28 255 18.5 0.1 18.8 18.2 08/22/2005 12:40:00 2.5 0.6 3.8 1.1 2.6 0.6 3.8 0.7 2 0.8 3.8 0.4 26 22 2 255 18.7 0.2 19.4 18.2 08/22/2005 12:50:00 2.1 0.6 3.8 0.4 2.2 0.6 3.8 0.4 1.5 0.6 3 0.4 9 18 350 255 18.9 0 19.4 18.5 08/22/2005 13:00:00 2.6 0.7 4.6 0.7 2.7 0.7 4.6 0.7 2.4 0.8 4.2 0.7 31 17 11 255 19 0 19.4 18.8 08/22/2005 13:10:00 2.1 0.4 3.4 1.1 2.2 0.4 3 1.1 1.8 0.7 3 0.4 19 19 26 255 19 0 19.7 18.8 08/22/2005 13:20:00 2.2 0.6 3.8 0.7 2.3 0.6 3.8 0.4 1.9 0.8 3.4 0.4 24 23 31 255 18.7 0.1 19.4 18.5 08/22/2005 13:30:00 2 0.6 3.4 0.4 1.9 0.7 3.8 0.4 1.8 0.5 3 0.4 10 27 53 255 18.9 0 19.4 18.5 08/22/2005 13:40:00 1.5 0.7 3 0.4 1.4 0.7 3 0.4 1.4 0.7 3 0.4 353 23 25 255 19.2 0.1 20 18.8 08/22/2005 13:50:00 1.5 0.6 3.4 0.4 1.4 0.6 3.4 0.4 1.2 0.6 2.6 0.4 10 21 10 255 19.5 0.2 20.3 19.4 08/22/2005 14:00:00 2.6 0.7 3.8 0.7 2.6 0.7 3.8 0.7 1.8 0.8 3.8 0.4 4 14 7 255 19.8 0 20.3 19.7 08/22/2005 14:10:00 1.6 0.6 3 0.4 1.6 0.7 3 0.4 1.2 0.6 2.6 0.4 1 16 354 255 19.7 0 20 19.4 08/22/2005 14:20:00 1.5 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 42 22 8 255 19.7 0 20 19.4 08/22/2005 14:30:00 1.8 0.5 3 0.4 1.8 0.5 3 0.4 1.2 0.5 3 0.4 12 16 356 255 19.7 0 20 19.4 08/22/2005 14:40:00 1.9 0.5 3.4 0.7 1.8 0.6 3.4 0.4 1.5 0.6 3 0.4 23 15 16 255 19.7 0 20 19.4 08/22/2005 14:50:00 1.7 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.4 0.4 2.3 0.4 43 20 33 255 19.5 0 19.7 19.4 08/22/2005 15:00:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 1.4 0.6 2.6 0.4 94 21 63 255 19.5 0 20 19.4 08/22/2005 15:10:00 2 0.7 4.2 0.4 1.9 0.7 3.8 0.4 1.7 0.8 3.4 0.4 51 15 80 255 19.5 0.1 20 19.1 08/22/2005 15:20:00 2.5 0.6 4.2 0.7 2.5 0.6 4.2 1.1 1.9 0.6 3.4 0.4 34 28 17 255 19.2 0 19.4 19.1 08/22/2005 15:30:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.8 0.5 3 0.4 38 21 17 255 19.5 0.1 20 19.4 08/22/2005 15:40:00 2.2 0.8 3.8 0.4 2.2 0.7 3.8 0.4 1.8 0.7 3 0.4 29 27 17 255 19.5 0.1 20.3 19.4 08/22/2005 15:50:00 3.4 1.4 6.8 0.7 3.3 1.3 6.8 0.7 2.6 1.2 5.7 0.4 36 23 37 255 19.2 0.2 20 18.5 08/22/2005 16:00:00 3.1 1 5.3 1.1 3 1.1 5.7 0.4 2 1 4.2 0.4 16 19 21 255 18.4 0.1 19.1 18.2 08/22/2005 16:10:00 3.7 0.9 6.5 1.9 3.6 1 6.1 1.5 2.9 1 5.3 0.4 23 17 27 255 18.2 0 18.5 18 08/22/2005 16:20:00 4.5 0.9 7.6 2.3 4.5 0.9 7.2 2.3 3.8 0.9 6.8 1.9 32 13 12 255 18.4 0.1 19.1 18.2 08/22/2005 16:30:00 4.9 1.1 8 2.3 4.9 1.1 7.6 2.3 3.5 1.3 6.5 0.4 16 15 32 255 19 0.1 19.1 18.5 08/22/2005 16:40:00 5 0.8 7.2 3 5 0.8 7.2 3 3.8 1 6.8 1.1 13 17 18 255 18.8 0 19.1 18.5 08/22/2005 16:50:00 4.9 1.1 8.4 1.5 4.9 1.1 8 1.9 3.3 1.2 6.5 0.4 13 16 16 255 18.6 0 19.1 18.5 08/22/2005 17:00:00 4.1 0.9 6.5 1.1 4.1 1 6.8 1.1 2.7 1.1 5.3 0.4 2 14 359 255 18.4 0 18.8 18.2 08/22/2005 17:10:00 4.8 1.2 8.8 1.5 4.8 1.1 8.8 1.9 3.6 1.3 7.6 0.7 354 16 336 255 17.9 0 18.8 17.7 08/22/2005 17:20:00 4.5 0.9 6.8 2.3 4.5 0.9 6.8 2.3 3.1 1 6.5 0.4 8 13 24 255 17.8 0 18 17.7 08/22/2005 17:30:00 5.3 0.9 7.6 2.6 5.4 0.8 7.6 2.6 4 1.1 6.8 1.5 14 12 10 255 17.6 0 17.7 17.4 08/22/2005 17:40:00 3.4 0.7 4.9 1.5 3.5 0.6 4.9 1.5 2.2 0.8 4.2 0.4 12 12 356 255 17.3 0 17.4 17.1 08/22/2005 17:50:00 5.1 1.6 8.8 1.9 5.1 1.5 8.8 2.3 3.9 1.7 8.4 0.4 18 11 20 255 17.3 0 17.4 17.1 08/22/2005 18:00:00 5.6 1.3 9.1 2.3 5.6 1.2 8.8 2.6 4 1.4 8.8 0.4 9 15 358 255 17.3 0 17.4 16.8 08/22/2005 18:10:00 6.4 1.2 9.5 3.4 6.4 1.2 9.5 3.4 4.7 1.5 8.4 1.5 12 12 29 255 16.9 0 17.1 16.8 08/22/2005 18:20:00 5.9 1 8.4 3 5.9 1 8.4 3 4.5 1.3 8 1.1 15 13 39 255 16.7 0 17.1 16.6 08/22/2005 18:30:00 6.1 1.5 10.3 3 6.1 1.4 10.3 3 4.6 1.8 8 0.4 15 16 4 255 16.5 0 16.8 16.3 08/22/2005 18:40:00 6.2 1.7 10.7 1.9 6.2 1.7 10.3 2.3 4.8 2 9.9 0.4 16 14 18 255 16.4 0 16.8 16.3 08/22/2005 18:50:00 7.5 1.2 10.7 3.4 7.4 1.2 10.3 3.8 5.8 1.4 10.7 2.3 20 13 16 255 16.3 0.1 16.8 16.3 08/22/2005 19:00:00 7.4 1.5 11.1 1.5 7.3 1.3 11.1 3 5.8 1.7 9.5 1.9 22 15 34 255 16.2 0.1 16.8 16.3 08/22/2005 19:10:00 6.7 2 11.1 1.9 6.7 1.9 10.7 2.6 5.4 2.1 11.5 2.3 23 13 35 255 16.2 0.1 16.8 16.3 08/22/2005 19:20:00 6.7 1.7 13.7 2.6 6.7 1.7 13.7 2.6 4.6 1.8 11.5 0.7 14 15 12 255 16.1 0 16.8 15.7 08/22/2005 19:30:00 6.7 1.1 10.3 4.6 6.7 1.1 10.7 3.8 5.2 1.5 9.9 1.5 19 12 14 255 15.8 0 16.3 15.7 08/22/2005 19:40:00 5.8 1.8 9.9 1.9 5.8 1.7 9.9 1.9 4.1 1.8 8.8 0.4 17 11 13 255 15.5 0 16 15.5 08/22/2005 19:50:00 6.7 1.5 11.8 3.8 6.7 1.5 11.5 3.8 5 1.5 9.9 1.5 20 14 37 255 15.4 0 16 15.5 08/22/2005 20:00:00 7.1 1.7 13.3 3.8 7.1 1.7 13.3 3.8 5.5 1.8 13 1.9 21 15 29 255 15.6 0.1 16.3 15.5 08/22/2005 20:10:00 4.6 1.1 7.2 2.3 4.6 1 7.2 1.9 3.4 1.2 6.5 0.4 26 13 35 255 15.3 0.2 16.3 15.2 08/22/2005 20:20:00 5.3 1.2 10.3 1.9 5.3 1.2 10.3 2.6 3.3 1.5 9.5 0.4 14 15 30 255 14.7 0.3 15.7 14.1 08/22/2005 20:30:00 5.5 1.4 9.5 2.6 5.5 1.3 9.1 3 3.5 1.7 8.4 0.4 12 15 8 255 14.1 0 14.4 14.1 08/22/2005 20:40:00 4.1 1.3 6.8 0.4 4.1 1.2 6.8 1.1 2.4 1.4 6.1 0.4 9 18 2 255 14.1 0.1 14.4 13.8 08/22/2005 20:50:00 2.9 1 5.7 0.4 2.9 1 5.7 0.4 1.2 1 4.9 0.4 357 38 344 255 13.6 0 14.1 13.3 08/22/2005 21:00:00 5.9 1.9 10.3 1.9 5.9 1.9 10.3 1.9 4.2 2.2 9.5 0.4 14 16 30 255 13.5 0.2 14.1 13.3 08/22/2005 21:10:00 6.3 1.2 9.1 3.4 6.3 1.1 9.1 3.8 4.7 1.2 8.4 1.9 21 12 15 255 14.2 0 14.9 13.8 08/22/2005 21:20:00 6.6 1.3 9.9 3.4 6.5 1.3 10.3 3.4 4.8 1.7 9.1 0.4 20 15 42 255 14.5 0 14.9 14.4 08/22/2005 21:30:00 6.1 1.1 9.1 2.6 6 1.1 9.1 3 4.1 1.3 8.4 0.4 21 14 21 255 14.4 0 14.9 14.4 08/22/2005 21:40:00 5.5 1.4 10.7 2.6 5.5 1.4 10.7 2.3 3.8 1.7 8.8 0.4 18 16 10 255 13.9 0 14.6 13.8 08/22/2005 21:50:00 6.3 1.2 9.9 3 6.2 1.2 10.3 3.4 4.4 1.6 8.4 0.4 18 15 41 255 13.9 0 14.4 13.8 08/22/2005 22:00:00 6.3 1.7 9.9 2.3 6.3 1.6 9.9 3 4.4 1.8 9.5 0.4 12 13 8 255 13.7 0 14.1 13.5 08/22/2005 22:10:00 6.2 1.5 10.3 1.9 6.2 1.5 10.3 2.3 4.2 1.7 9.5 0.4 9 16 10 255 13.3 0 13.5 13 08/22/2005 22:20:00 6.4 1.4 9.5 3 6.5 1.3 9.5 3 4.6 1.7 8.4 0.4 16 11 12 255 12.8 0 13 12.5 08/22/2005 22:30:00 5.7 1.5 9.1 2.6 5.7 1.4 9.1 1.9 3.8 1.7 8 0.4 14 12 15 255 12.5 0.1 12.7 12.5 08/22/2005 22:40:00 4.9 1.2 8 1.9 5 1.1 8.4 2.3 3.1 1.5 7.6 0.4 12 13 16 255 12.3 0 12.7 11.9 08/22/2005 22:50:00 6 1.5 11.1 3 6 1.4 10.7 3 4.3 1.5 8.8 0.7 17 15 2 255 12 0 12.5 11.9 08/22/2005 23:00:00 7.5 1.5 11.1 3 7.4 1.4 11.1 3.4 5.8 1.7 9.5 1.9 23 13 28 255 12.4 0.1 13 11.9 08/22/2005 23:10:00 8.2 1.6 13.7 4.9 8.1 1.6 13.3 4.9 6.1 1.9 11.1 1.5 19 13 10 255 12.7 0 13.3 12.7 08/22/2005 23:20:00 7.6 2 14.5 3.4 7.5 2 14.5 3.4 6 2 13.3 1.5 23 15 22 255 12.9 0 13 12.7 08/22/2005 23:30:00 8.8 2 14.9 4.9 8.8 2 15.3 4.9 7.2 2 13.7 3.4 27 14 22 255 13.2 0 13.3 13 08/22/2005 23:40:00 9.6 1.7 14.1 5.3 9.5 1.7 14.1 5.3 7.9 1.8 12.6 3.8 25 14 11 255 13.3 0 13.3 13.3 08/22/2005 23:50:00 8.5 1.5 13 4.2 8.4 1.5 13 4.2 6.3 1.6 9.9 2.6 23 15 1 255 13.3 0 13.5 13.3 08/23/2005 00:00:00 7.8 1.7 11.5 3 7.8 1.6 11.5 3.4 6.5 1.7 10.7 2.6 27 13 49 255 13.3 0 13.3 13.3 08/23/2005 00:10:00 8.7 1.6 13 4.6 8.6 1.6 13.3 4.9 6.9 1.7 11.1 1.9 23 14 15 255 13.3 0 13.3 13.3 08/23/2005 00:20:00 8 2 15.3 4.6 8 2 14.9 4.2 6.4 1.9 14.1 2.6 30 14 19 255 13.5 0 13.5 13.3 08/23/2005 00:30:00 8.1 1.5 12.6 4.6 8 1.5 13 4.2 6.4 1.5 9.9 3.4 26 16 16 255 13.5 0 13.5 13.3 08/23/2005 00:40:00 8.6 1.5 12.6 3.8 8.5 1.5 12.2 3.4 6.9 1.6 11.1 3 35 14 54 255 13.7 0 13.8 13.5 08/23/2005 00:50:00 7.3 1.5 12.2 3.8 7.2 1.5 12.2 3.8 5.7 1.5 9.9 1.9 33 17 356 255 13.6 0 13.8 13.5 08/23/2005 01:00:00 7.9 1.8 13.7 4.6 7.9 1.8 13.7 3.8 6.6 1.7 12.2 2.6 36 14 10 255 13.7 0 14.1 13.5 08/23/2005 01:10:00 9.5 2.4 14.9 4.6 9.4 2.4 15.3 4.2 7.8 2 13 3.4 32 17 17 255 14.1 0 14.4 13.8 08/23/2005 01:20:00 9.7 2.1 16.1 5.3 9.7 2.1 15.6 4.6 7.6 2.3 13 2.3 20 15 27 255 14.2 0 14.6 14.1 08/23/2005 01:30:00 10.1 2.1 14.5 4.2 10 2.1 14.9 3.4 8.1 1.9 13 1.9 27 15 37 255 13.7 0.2 14.1 13.3 08/23/2005 01:40:00 8.6 2.3 14.5 3 8.5 2.3 14.1 3.4 6.7 2.2 12.2 1.9 22 18 52 255 13 0.2 13.3 12.7 08/23/2005 01:50:00 9.2 1.7 13.7 4.9 9.1 1.7 13.7 4.6 7.2 1.9 12.6 1.9 19 13 11 255 12.3 0 12.7 12.2 08/23/2005 02:00:00 7.9 1.7 11.8 3.8 7.9 1.7 12.2 3.8 6.3 1.7 10.3 3 28 17 26 255 12.1 0 12.2 11.9 08/23/2005 02:10:00 6.6 2 12.2 2.6 6.6 2 12.6 2.6 5.3 2 12.6 1.9 35 18 34 255 12 0 12.2 11.9 08/23/2005 02:20:00 6.1 1.4 9.9 2.3 6 1.4 10.3 2.6 4.7 1.4 9.1 1.5 47 19 4 255 12 0 12.2 11.9 08/23/2005 02:30:00 6.1 1.1 8.8 3 6.1 1.1 8.8 3.4 4.7 1.2 8 1.5 65 21 73 255 11.8 0 11.9 11.7 08/23/2005 02:40:00 5.1 1.2 8.8 2.6 5.1 1.1 8.8 2.3 4.1 1.2 7.2 1.5 76 20 130 255 11.9 0.1 12.2 11.7 08/23/2005 02:50:00 4.5 1 7.6 2.6 4.5 1.1 7.6 2.6 3.4 1.3 7.2 0.4 89 15 91 255 12 0.1 12.2 11.9 08/23/2005 03:00:00 4.4 1.5 8 1.1 4.4 1.4 9.1 1.5 3.3 1.5 7.6 0.4 84 19 79 255 11.9 0 11.9 11.9 08/23/2005 03:10:00 4.5 1 6.8 1.5 4.5 1 7.2 1.9 3.2 1 5.7 0.4 88 21 30 255 11.8 0 11.9 11.7 08/23/2005 03:20:00 4.9 1 8 2.6 4.9 1 8 3 3.8 1.1 7.2 0.7 69 17 57 255 11.7 0 11.9 11.7 08/23/2005 03:30:00 5.6 1.2 8 2.3 5.6 1.1 8 2.3 4.4 1.1 8 0.7 75 19 126 255 12 0 12.2 11.7 08/23/2005 03:40:00 5.6 1.3 9.1 2.3 5.5 1.3 9.1 2.3 4 1.5 7.6 0.4 79 17 83 255 12 0 12.2 11.9 08/23/2005 03:50:00 5.3 1.3 8.4 2.3 5.3 1.3 8.4 1.1 3.9 1.5 7.6 0.4 81 17 89 255 11.9 0 11.9 11.7 08/23/2005 04:00:00 6.1 1.5 10.3 2.6 6 1.5 11.1 2.6 4.6 1.6 8.8 0.7 76 19 79 255 11.9 0 11.9 11.9 08/23/2005 04:10:00 5.5 1.7 10.3 2.3 5.5 1.7 9.9 2.3 4.2 1.7 8.4 0.4 70 19 52 255 12.2 0 12.2 11.9 08/23/2005 04:20:00 6.1 1.5 10.7 2.3 6 1.6 10.3 1.9 4.9 1.7 8.4 0.4 62 21 68 255 12.3 0 12.5 12.2 08/23/2005 04:30:00 6.8 1.6 10.7 3 6.8 1.6 10.7 3 5.6 1.7 10.3 1.5 43 15 45 255 12.4 0 12.7 12.2 08/23/2005 04:40:00 7.5 1.5 12.2 3.8 7.5 1.5 11.8 3.8 5.8 1.5 11.1 1.9 43 19 23 255 12.7 0 12.7 12.5 08/23/2005 04:50:00 7 2.1 13 2.6 7.1 2 13 3.4 5.5 1.9 11.1 1.9 75 20 52 255 12.7 0 13 12.5 08/23/2005 05:00:00 6.3 1.5 11.5 2.6 6.3 1.5 10.7 2.6 5.1 1.5 10.3 1.5 55 20 68 255 12.6 0 12.7 12.5 08/23/2005 05:10:00 6 1.1 9.5 3 5.9 1.1 9.5 3.4 4.8 1.2 8 1.9 78 19 69 255 12.5 0.1 12.7 12.2 08/23/2005 05:20:00 7.8 1.7 12.2 3.4 7.8 1.8 12.2 3 6.5 1.8 10.7 2.6 42 17 30 255 12.8 0.2 13 12.5 08/23/2005 05:30:00 5.7 1.5 9.5 1.9 5.7 1.6 9.1 1.5 4.4 1.5 8.4 0.7 54 19 29 255 12.9 0 13.3 12.7 08/23/2005 05:40:00 6.4 1.6 11.5 2.3 6.3 1.5 11.8 2.3 5.1 1.7 9.5 0.4 49 17 40 255 12.8 0 12.7 12.7 08/23/2005 05:50:00 6 1.3 10.7 2.3 6 1.3 10.3 3 4.9 1.2 8 1.5 55 15 54 255 13 0 13.3 12.7 08/23/2005 06:00:00 4.6 1.7 10.7 1.9 4.6 1.7 11.1 0.7 3.5 1.7 9.1 0.4 68 23 49 255 13.1 0 13.3 13 08/23/2005 06:10:00 5.2 1.4 11.8 1.1 5.2 1.4 10.7 1.1 3.8 1.6 8 0.4 84 17 77 255 12.7 0 13 12.5 08/23/2005 06:20:00 7.1 1.9 12.2 2.6 7.1 1.9 12.2 3 5.8 1.7 10.3 1.5 59 19 55 255 12.9 0.2 13.3 12.5 08/23/2005 06:30:00 4.8 1.2 8 1.9 4.9 1.2 8.8 1.9 3.6 1.2 6.1 0.4 73 20 66 255 12.9 0.1 13.3 12.7 08/23/2005 06:40:00 5.9 2 11.1 1.5 5.8 1.9 10.7 2.6 4.6 1.9 10.7 1.1 62 20 53 255 12.9 0.1 13 12.7 08/23/2005 06:50:00 7.6 1.9 12.6 3 7.5 1.9 12.6 3 6.3 1.9 10.7 2.3 43 17 25 255 13.5 0.1 13.8 13 08/23/2005 07:00:00 7 2.4 13.7 2.3 7 2.3 13.7 2.3 5.6 2.2 13.3 1.1 49 21 14 255 13.8 0 13.8 13.5 08/23/2005 07:10:00 8.3 2.3 17.6 4.2 8.3 2.2 17.2 4.6 6.7 2.1 14.1 2.6 46 16 26 255 13.9 0 14.1 13.8 08/23/2005 07:20:00 6.3 1.7 11.1 2.6 6.3 1.8 10.7 2.3 5.2 1.9 10.3 1.1 71 24 67 255 13.9 0 14.1 13.5 08/23/2005 07:30:00 7.4 1.7 13.3 3.8 7.4 1.7 12.6 3.8 6 1.7 10.7 1.5 62 22 43 255 14.1 0.1 14.6 13.8 08/23/2005 07:40:00 7.7 2.1 13.7 2.6 7.6 2.1 13.7 3 6.5 2 13 2.3 51 18 40 255 14.6 0.2 15.2 14.4 08/23/2005 07:50:00 9.7 2.5 17.2 3 9.7 2.5 17.2 3.4 7.9 2.2 14.5 3 59 20 63 255 15.3 0 16 15.2 08/23/2005 08:00:00 8.9 2.6 19.1 4.2 8.9 2.6 19.1 3.8 7.7 2.6 17.9 3 48 15 39 255 15.4 0 15.7 15.5 08/23/2005 08:10:00 7.3 1.6 11.1 3.8 7.3 1.5 11.8 3.8 5.9 1.5 9.9 1.9 66 22 82 255 15.1 0 15.5 14.9 08/23/2005 08:20:00 7.6 1.5 12.2 4.2 7.6 1.5 12.2 4.6 6.3 1.5 11.5 3 55 18 48 255 14.6 0 14.9 14.6 08/23/2005 08:30:00 9 2.2 15.6 3.8 9.1 2.2 15.6 4.2 7.5 2.1 14.1 3 51 19 43 255 14.4 0.1 14.6 14.1 08/23/2005 08:40:00 9.5 2.5 17.2 4.9 9.5 2.6 17.6 4.9 7.8 2.5 16.8 3 52 18 50 255 13.9 0 14.4 13.8 08/23/2005 08:50:00 9.8 2.3 17.2 4.6 9.8 2.3 17.6 4.9 8 2.3 15.3 2.6 41 21 46 255 13.5 0 13.8 13 08/23/2005 09:00:00 10.1 2.9 18.3 4.6 10.1 2.9 18.3 3.8 8.3 2.9 17.2 3 48 17 60 255 13.1 0 13.3 13 08/23/2005 09:10:00 11 2.3 17.6 4.9 11 2.3 18.7 5.3 8.9 2.3 15.6 3.8 44 17 43 255 12.9 0 13 12.7 08/23/2005 09:20:00 10.4 2.4 16.8 4.2 10.3 2.4 17.6 4.9 8.6 2.4 15.3 3.4 49 16 24 255 13 0 13 12.7 08/23/2005 09:30:00 9.2 2.4 15.6 3.8 9.1 2.4 15.6 4.2 7.4 2.3 14.9 2.6 53 20 50 255 13.1 0.1 13.3 12.7 08/23/2005 09:40:00 7.6 2.6 15.3 3.8 7.5 2.5 15.3 3.4 6 2.4 13.7 1.9 61 16 64 255 13.3 0 13.3 13 08/23/2005 09:50:00 6.8 1.4 10.3 3.4 6.8 1.3 9.5 3.4 5.5 1.6 9.9 1.9 78 18 54 255 13.1 0 13.3 13 08/23/2005 10:00:00 6.2 1.7 10.7 1.9 6.2 1.7 10.3 2.3 4.9 1.8 9.5 0.7 88 17 94 255 13.3 0 13.3 13.3 08/23/2005 10:10:00 7 2.1 14.5 3.8 7 2.1 14.1 3.8 5.5 2 11.1 0.7 69 18 46 255 13.3 0 13.3 13 08/23/2005 10:20:00 6.9 1.9 13 1.9 6.9 1.8 12.2 3 5.4 1.7 10.7 1.1 60 23 51 255 12.9 0.1 13.3 12.7 08/23/2005 10:30:00 6.4 1.7 10.3 2.3 6.4 1.8 10.7 2.3 5 1.9 10.3 1.1 48 21 48 255 12.9 0 13 12.7 08/23/2005 10:40:00 7.5 1.6 11.5 3.8 7.4 1.6 11.5 3.4 6.2 1.7 10.7 1.9 37 15 38 255 12.9 0 13 12.7 08/23/2005 10:50:00 10.4 2.3 16.1 5.7 10.4 2.4 16.1 4.6 9 2.4 15.6 4.6 48 17 47 255 13.3 0 13.5 13 08/23/2005 11:00:00 8.9 2.5 14.9 3 8.8 2.5 14.9 3 7.3 2.3 13.7 2.6 43 16 30 255 13.6 0 13.8 13.3 08/23/2005 11:10:00 8.6 2.5 14.1 3 8.6 2.5 14.1 3 6.8 2.3 12.6 2.3 52 17 61 255 13.9 0 14.1 13.8 08/23/2005 11:20:00 10.2 2.1 17.9 4.9 10.1 2.1 18.3 4.9 8.3 2 14.5 3.4 53 19 101 255 14.2 0 14.4 14.1 08/23/2005 11:30:00 9.3 2.2 15.6 4.6 9.2 2.3 16.1 4.6 7.4 2 14.1 3.8 38 15 49 255 14.2 0.1 14.4 13.8 08/23/2005 11:40:00 12 2.6 19.5 4.9 11.9 2.7 19.1 4.9 10 2.6 17.6 4.2 41 17 14 255 14.2 0 14.6 13.8 08/23/2005 11:50:00 10 2.7 18.3 4.2 10 2.6 18.7 4.6 8.1 2.5 15.6 3 42 20 44 255 14.4 0 14.6 14.4 08/23/2005 12:00:00 11.6 3.1 22.1 5.7 11.6 3.1 21.8 6.1 9.5 2.9 19.1 3.4 38 14 35 255 14.6 0 14.9 14.6 08/23/2005 12:10:00 9.1 2.1 14.1 4.2 9.1 2.2 14.1 3.4 7.6 2.1 14.5 2.3 43 17 40 255 14.6 0 14.9 14.6 08/23/2005 12:20:00 9.9 2.5 16.1 4.2 9.9 2.6 16.4 4.2 8.5 2.4 16.8 3.4 42 15 44 255 14.4 0 14.6 14.4 08/23/2005 12:30:00 10.8 2 16.8 6.1 10.7 2 16.4 5.7 9.2 2.1 15.6 3.8 37 13 47 255 13.9 0 14.4 13.5 08/23/2005 12:40:00 11.6 2.3 16.8 6.5 11.5 2.4 16.8 6.1 9.7 2.1 15.6 3.8 39 13 44 255 13.7 0 13.8 13.5 08/23/2005 12:50:00 9.8 2.1 17.2 5.7 9.7 2.2 17.2 5.7 8.1 2 16.8 3.8 39 15 51 255 13.8 0 13.8 13.5 08/23/2005 13:00:00 8.9 2.2 15.3 2.6 8.9 2.2 14.9 3.4 7.5 2.2 12.6 2.6 42 17 37 255 13.9 0 14.1 13.8 08/23/2005 13:10:00 7.6 1.7 12.6 3 7.5 1.7 12.2 2.6 6.1 1.7 11.1 2.3 45 18 15 255 13.9 0 14.1 13.8 08/23/2005 13:20:00 6.6 2.1 13.3 2.6 6.5 2.1 13 2.6 5.5 1.8 12.2 2.3 48 20 44 255 14.2 0 14.6 14.1 08/23/2005 13:30:00 6.5 2.1 13.7 2.6 6.5 2.2 13.3 2.6 5.4 2.1 11.1 0.7 58 21 46 255 14.8 0.2 15.2 14.6 08/23/2005 13:40:00 6.1 1.5 10.7 2.3 6 1.5 10.3 2.3 5 1.3 9.1 2.3 63 22 74 255 15.4 0.2 16 15.2 08/23/2005 13:50:00 3.9 1 7.2 1.9 3.7 1 6.8 1.5 3.1 0.9 6.5 1.1 79 21 60 255 16.1 0.1 16.8 16 08/23/2005 14:00:00 5 1.8 11.8 2.3 4.9 1.8 11.8 1.9 4 1.7 10.3 1.1 52 20 46 255 17.2 0.5 18.8 16.6 08/23/2005 14:10:00 7.9 1.6 12.6 3.8 7.8 1.7 13.3 3.4 6.3 1.5 11.1 2.6 29 17 40 255 18.7 0.1 19.1 18.2 08/23/2005 14:20:00 10.3 2.1 16.1 6.1 10.3 2.1 15.6 6.5 8.5 2 14.1 3.8 34 15 39 255 18.5 0.1 19.1 18.2 08/23/2005 14:30:00 9.9 2.5 16.8 4.2 9.9 2.5 16.4 3.8 7.9 2.6 15.3 3.4 26 15 14 255 18.5 0.1 19.1 18 08/23/2005 14:40:00 9.7 1.5 13.7 6.1 9.6 1.6 14.5 5.7 7.9 1.6 12.6 3.8 28 16 35 255 19.2 0.2 20 18.8 08/23/2005 14:50:00 10.7 2.1 16.1 4.2 10.6 2.2 16.1 3.4 8.5 2.4 15.6 2.6 21 13 35 255 19.7 0 20.3 19.4 08/23/2005 15:00:00 9.1 2.1 16.4 4.9 9.1 2.2 15.6 4.9 7.2 2.4 14.5 1.5 21 13 39 255 20.2 0 20.5 20 08/23/2005 15:10:00 8.4 2.3 14.9 3.8 8.3 2.4 15.6 3.8 6.2 2.3 13 0.7 19 17 21 255 20.5 0 20.8 20.3 08/23/2005 15:20:00 9.4 2 14.9 4.6 9.4 2 14.9 4.2 7.6 2.2 12.6 1.5 21 13 51 255 20.3 0 20.8 20.3 08/23/2005 15:30:00 8.4 2.3 13.3 3 8.3 2.3 13.7 3 6.6 2.2 12.2 2.3 16 14 3 255 20.5 0.1 21.1 20.3 08/23/2005 15:40:00 9.8 2.5 16.8 4.6 9.7 2.6 16.8 3.8 7.9 2.7 16.1 2.6 17 12 14 255 20.7 0.1 21.1 20.5 08/23/2005 15:50:00 9.5 2.1 16.1 4.2 9.5 2.2 15.6 4.6 7.5 2.6 14.5 2.3 17 16 26 255 20.5 0 21.1 20.5 08/23/2005 16:00:00 9.3 2.5 17.6 3.4 9.3 2.6 17.6 3 7.3 2.6 16.1 1.9 16 15 4 255 20.5 0.1 21.1 20.3 08/23/2005 16:10:00 8.9 2.1 14.5 3.8 8.9 2.2 14.5 3.4 6.5 2.2 12.6 1.9 10 17 28 255 19.6 0.3 20.5 19.4 08/23/2005 16:20:00 9.1 2.3 15.3 3.8 9.1 2.3 15.3 3.4 6.7 2.3 13.3 1.5 8 17 28 255 19.2 0.1 20 19.1 08/23/2005 16:30:00 8.6 1.8 13 4.6 8.5 1.9 13.7 4.2 6.2 1.8 11.1 1.5 11 16 6 255 19.5 0 20 19.4 08/23/2005 16:40:00 8.2 1.9 13 3.4 8.1 2 13.3 3 6 2 11.5 2.3 11 18 12 255 19.5 0 20 19.4 08/23/2005 16:50:00 7.7 2 14.1 3.4 7.6 2 14.5 2.6 5.5 2.3 12.2 1.1 8 15 15 255 19.4 0 19.4 19.1 08/23/2005 17:00:00 7.6 2 13 2.6 7.5 2.1 13.7 1.9 5.6 2 12.2 1.5 8 17 8 255 19.2 0 19.4 19.1 08/23/2005 17:10:00 7.9 2 12.2 3 7.9 2 12.2 2.6 6.2 2.1 12.2 1.9 15 17 12 255 19.2 0 19.4 19.1 08/23/2005 17:20:00 8.4 2 13.3 3 8.3 2.1 13.3 3 6 2 11.5 1.5 8 16 28 255 19.4 0 19.7 19.1 08/23/2005 17:30:00 6.8 1.9 13 1.5 6.6 2 13 2.3 4.9 2.1 11.1 1.1 7 19 3 255 19.1 0.1 19.4 18.8 08/23/2005 17:40:00 7.6 1.8 13.7 3.8 7.4 2 13.3 3.4 5.6 1.8 10.7 2.3 1 20 6 255 18.6 0.2 19.1 18.2 08/23/2005 17:50:00 6.7 1.7 10.7 3 6.5 1.7 11.1 3 4.6 1.7 9.5 1.1 2 22 60 255 18.4 0 18.5 18.2 08/23/2005 18:00:00 5.4 1.9 10.7 1.5 5.3 2 10.7 1.5 4.1 1.8 8.4 0.7 7 21 37 255 18.4 0 18.8 18 08/23/2005 18:10:00 3.9 2.2 10.7 0.4 3.7 2.2 9.9 0.4 2.9 2 9.9 0.4 288 38 324 255 18.1 0 18.5 17.7 08/23/2005 18:20:00 2.5 1.5 6.5 0.4 2.3 1.5 6.5 0.4 1.9 1.2 4.9 0.4 241 27 240 255 17.5 0.2 18 17.1 08/23/2005 18:30:00 3.7 1.5 7.2 0.4 3.7 1.5 7.2 0.4 2.7 1.3 5.7 0.4 225 28 213 255 16.9 0.1 17.4 16.6 08/23/2005 18:40:00 4.8 1.7 8.8 1.1 5 1.6 8.4 1.1 4 1.5 7.6 0.7 193 17 222 255 16.4 0 16.8 16.3 08/23/2005 18:50:00 4.6 1.2 7.6 1.1 4.6 1.3 7.6 0.7 3.4 1.2 6.5 0.4 193 20 203 255 16.2 0 16.8 16 08/23/2005 19:00:00 3.7 1.1 7.2 1.5 3.7 1.1 6.8 1.1 2.6 1.1 6.1 0.4 195 21 195 255 16 0 16.6 16 08/23/2005 19:10:00 2.5 1.1 4.9 0.4 2.3 1.1 4.6 0.4 1.6 1.2 5.3 0.4 195 26 194 255 15.9 0 16.3 15.7 08/23/2005 19:20:00 2.1 0.6 3.8 0.4 1.9 0.7 3.8 0.4 1.3 0.7 3.4 0.4 181 24 214 255 15.7 0 16.3 15.7 08/23/2005 19:30:00 2.3 0.6 4.6 0.4 2.2 0.6 4.2 0.7 1.5 0.7 3.8 0.4 206 19 198 255 15.4 0.2 16 15.2 08/23/2005 19:40:00 2.7 0.8 4.9 0.4 2.6 0.9 5.3 0.4 1.5 0.9 3.8 0.4 206 11 212 255 15 0 15.7 14.6 08/23/2005 19:50:00 2.4 0.7 4.2 0.7 2.2 0.7 3.8 0.7 1.2 0.8 3 0.4 207 9 201 255 14.5 0.2 15.2 14.1 08/23/2005 20:00:00 2.6 0.5 4.6 0.7 2.5 0.5 4.2 0.4 1.4 0.5 2.6 0.4 203 10 195 255 13.9 0 14.4 13.5 08/23/2005 20:10:00 2.3 0.6 3.8 0.4 2.3 0.5 3.4 0.4 1.5 0.5 2.6 0.4 190 9 189 255 13.5 0 14.1 13.3 08/23/2005 20:20:00 2.9 0.8 4.9 1.1 2.9 0.7 4.6 1.1 1.8 0.7 3.8 0.4 193 13 189 255 12.9 0.1 13.5 12.7 08/23/2005 20:30:00 2.4 1 4.9 0.4 2.4 1 5.3 0.4 1.1 0.9 3.8 0.4 196 18 206 255 12.7 0 13 12.5 08/23/2005 20:40:00 3.6 1.2 6.1 1.1 3.6 1.1 6.1 1.1 2.5 1 4.9 0.4 195 15 209 255 12.3 0 12.7 12.2 08/23/2005 20:50:00 2 0.6 4.2 0.4 1.9 0.6 3.8 0.4 1 0.6 2.6 0.4 201 10 192 255 12.3 0 12.7 11.9 08/23/2005 21:00:00 2.3 0.5 3.8 0.7 2.5 0.5 3.8 1.1 1.9 0.5 3.4 0.7 183 9 192 255 11.8 0.1 12.2 11.7 08/23/2005 21:10:00 1.8 0.5 3.4 0.4 2 0.6 3.4 0.7 1.3 0.5 2.6 0.4 182 10 196 255 11.7 0 11.7 11.4 08/23/2005 21:20:00 2 0.4 3 1.1 1.9 0.4 3 1.1 0.9 0.4 1.9 0.4 196 6 197 255 11.3 0 11.7 11.4 08/23/2005 21:30:00 1.8 0.7 3.8 0.4 2 0.5 3.4 0.7 0.9 0.5 2.3 0.4 187 8 191 255 11.3 0 11.4 11.1 08/23/2005 21:40:00 1.6 0.5 3 0.4 2 0.5 3 0.7 0.9 0.4 1.9 0.4 180 8 180 255 11.1 0 11.4 11.1 08/23/2005 21:50:00 1.9 0.5 3.4 1.1 2.3 0.4 3.4 1.5 1.3 0.5 2.3 0.4 181 7 189 255 11.1 0 11.1 11.1 08/23/2005 22:00:00 2.3 0.4 3.4 1.5 2.2 0.3 3.4 1.1 1.3 0.4 2.3 0.4 193 6 186 255 11.1 0 11.1 11.1 08/23/2005 22:10:00 2.1 0.3 3 1.5 2 0.3 3 1.1 0.9 0.4 2.3 0.4 200 6 197 255 11.1 0 11.1 11.1 08/23/2005 22:20:00 3 0.6 4.6 1.5 2.8 0.6 4.2 1.1 1.4 0.6 3 0.4 205 7 196 255 11 0 11.1 10.9 08/23/2005 22:30:00 3.3 0.5 4.6 1.9 3.1 0.5 4.6 1.5 1.6 0.6 3 0.4 206 9 231 255 10.9 0 11.1 10.9 08/23/2005 22:40:00 2.5 0.5 4.2 0.7 2.4 0.5 3.8 0.7 1.3 0.6 3.4 0.4 202 9 187 255 10.9 0 11.1 10.9 08/23/2005 22:50:00 0.9 0.8 3 0.4 0.8 0.7 3 0.4 0.5 0.3 2.6 0.4 222 51 208 255 10.8 0 10.9 10.6 08/23/2005 23:00:00 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 337 49 9 255 10.6 0 10.9 10.6 08/23/2005 23:10:00 1.5 0.7 2.6 0.4 1.4 0.6 2.6 0.4 0.7 0.4 1.9 0.4 205 26 206 255 10.6 0 10.6 10.6 08/23/2005 23:20:00 2.4 0.9 4.9 0.7 2.2 1 4.9 0.4 1.1 0.8 4.6 0.4 202 12 204 255 10.6 0 10.6 10.6 08/23/2005 23:30:00 3 0.5 4.2 1.5 3 0.5 4.2 1.5 1.5 0.6 3 0.4 211 10 233 255 10.6 0 10.9 10.6 08/23/2005 23:40:00 2.9 0.7 5.3 1.1 2.9 0.8 5.3 0.7 1.6 0.8 4.2 0.4 208 15 199 255 10.8 0 11.1 10.6 08/23/2005 23:50:00 3.3 0.6 4.9 1.1 3.2 0.6 4.9 1.5 1.9 0.7 3.4 0.4 207 11 202 255 11.1 0 11.1 10.9 08/24/2005 00:00:00 2.6 0.7 4.6 1.1 2.5 0.7 4.2 0.7 1.4 0.7 4.2 0.4 206 13 206 255 11.5 0.1 11.7 11.1 08/24/2005 00:10:00 2.6 0.7 4.2 0.7 2.4 0.7 3.8 0.7 1.2 0.6 2.6 0.4 210 12 195 255 11.7 0 11.9 11.7 08/24/2005 00:20:00 2.7 0.6 4.6 0.7 2.5 0.6 4.2 0.7 1.4 0.7 3.4 0.4 210 13 201 255 12 0 12.2 11.9 08/24/2005 00:30:00 2.4 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.3 0.7 3 0.4 206 15 209 255 12.3 0 12.5 11.9 08/24/2005 00:40:00 2.7 0.6 4.6 0.4 2.6 0.7 4.2 0.4 1.6 0.7 3.4 0.4 210 13 197 255 12.4 0 12.5 12.2 08/24/2005 00:50:00 3.6 0.7 6.1 2.3 3.5 0.7 5.7 1.9 2.3 0.7 4.6 0.4 210 12 181 255 12.4 0 12.5 12.2 08/24/2005 01:00:00 3.6 0.7 5.3 1.5 3.4 0.7 5.3 1.5 2.3 0.8 4.9 0.7 211 10 215 255 12.6 0 12.7 12.5 08/24/2005 01:10:00 2.2 0.5 3.8 0.7 2 0.5 3.4 0.7 1.1 0.7 3 0.4 212 13 219 255 12.8 0 12.7 12.7 08/24/2005 01:20:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 0.9 0.6 2.6 0.4 204 22 206 255 12.8 0 12.7 12.7 08/24/2005 01:30:00 1.5 1 3.8 0.4 1.3 1 3.4 0.4 0.8 0.7 3 0.4 220 26 208 255 12.8 0 13 12.5 08/24/2005 01:40:00 1 0.6 3 0.4 0.8 0.6 3 0.4 0.4 0.3 2.3 0.4 207 22 229 255 12.5 0 12.7 12.2 08/24/2005 01:50:00 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 0.7 0.5 2.6 0.4 221 13 219 255 12.3 0 12.5 12.2 08/24/2005 02:00:00 2.6 0.5 4.2 1.5 2.5 0.5 3.8 1.1 1.2 0.5 2.6 0.4 218 10 204 255 12 0 12.2 11.9 08/24/2005 02:10:00 2.5 0.6 4.2 1.1 2.4 0.7 4.2 0.4 1.2 0.6 2.6 0.4 229 16 222 255 11.9 0 12.2 11.7 08/24/2005 02:20:00 1.6 0.7 3.4 0.4 1.5 0.7 3 0.4 0.5 0.4 2.3 0.4 252 20 257 255 11.9 0 11.9 11.7 08/24/2005 02:30:00 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.1 1.1 0.4 289 26 4 255 12.1 0 12.2 11.9 08/24/2005 02:40:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 260 0 260 255 12 0 12.2 11.9 08/24/2005 02:50:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 285 12 260 255 11.8 0 11.9 11.7 08/24/2005 03:00:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 277 18 256 255 11.7 0 11.9 11.7 08/24/2005 03:10:00 2.6 0.7 3.8 0.4 2.5 0.7 3.8 0.7 1.3 0.7 3.4 0.4 221 12 233 255 11.7 0 11.7 11.7 08/24/2005 03:20:00 1.9 0.8 4.6 0.4 1.7 0.9 4.6 0.4 0.9 0.7 3.4 0.4 233 17 231 255 11.7 0 11.7 11.4 08/24/2005 03:30:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 245 15 251 255 11.6 0 11.7 11.4 08/24/2005 03:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 217 0 217 255 11.1 0 11.4 10.9 08/24/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 217 0 255 255 10.7 0 11.1 10.6 08/24/2005 04:00:00 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 140 56 91 255 10.6 0 10.9 10.6 08/24/2005 04:10:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 96 2 90 255 10.5 0 10.6 10.6 08/24/2005 04:20:00 1.7 0.4 2.6 0.7 1.6 0.5 3 0.4 0.7 0.4 2.3 0.4 76 9 65 255 10.4 0 10.6 10.3 08/24/2005 04:30:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 86 1 94 255 10.3 0 10.6 10.3 08/24/2005 04:40:00 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 85 0 86 255 10.4 0 10.6 10.3 08/24/2005 04:50:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 74 5 76 255 10.2 0 10.3 10.1 08/24/2005 05:00:00 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.4 0 0.4 0.4 74 4 72 255 10 0 10.1 9.8 08/24/2005 05:10:00 0.9 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 126 16 105 255 10 0 10.1 9.8 08/24/2005 05:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 81 7 81 255 9.8 0 9.8 9.8 08/24/2005 05:30:00 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 21 9 33 255 9.8 0 10.1 9.8 08/24/2005 05:40:00 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 14 0 14 255 10 0 10.1 9.8 08/24/2005 05:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 0 14 255 10 0 10.1 10.1 08/24/2005 06:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 24 14 43 255 10.1 0 10.3 10.1 08/24/2005 06:10:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 10 44 255 10.3 0 10.3 10.3 08/24/2005 06:20:00 0.8 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 67 6 78 255 10.3 0 10.6 10.3 08/24/2005 06:30:00 1.9 0.6 3 0.4 1.7 0.6 2.6 0.4 1 0.5 2.3 0.4 84 10 77 255 10.5 0 10.6 10.3 08/24/2005 06:40:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 103 13 80 255 10.7 0 11.1 10.6 08/24/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 86 255 11.3 0 11.4 11.1 08/24/2005 07:00:00 1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 86 0 86 255 11.4 0 11.4 11.4 08/24/2005 07:10:00 1.6 0.4 2.6 0.4 1.4 0.5 2.3 0.4 0.8 0.4 1.5 0.4 78 8 80 255 11.3 0 11.4 11.4 08/24/2005 07:20:00 1.3 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.4 0.2 1.1 0.4 71 11 55 255 11.3 0 11.4 11.1 08/24/2005 07:30:00 1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0.1 1.1 0.4 75 11 68 255 11.1 0 11.4 11.1 08/24/2005 07:40:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 69 5 78 255 11.9 0.7 13.3 11.1 08/24/2005 07:50:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 83 16 101 255 14.2 0.3 14.9 13.3 08/24/2005 08:00:00 0.5 0.4 1.9 0.4 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 110 19 94 255 14.8 0.1 15.7 14.6 08/24/2005 08:10:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 90 24 91 255 15.1 0.1 15.7 14.9 08/24/2005 08:20:00 1.6 0.5 2.6 0.7 1.4 0.5 2.3 0.4 1.2 0.6 2.6 0.4 78 21 70 255 15.4 0 16 15.2 08/24/2005 08:30:00 2 0.4 3 1.1 1.7 0.4 2.6 0.4 1.2 0.6 2.6 0.4 101 14 100 255 15.6 0.1 16.3 15.5 08/24/2005 08:40:00 2.1 0.7 4.2 0.4 1.9 0.7 3.8 0.4 1.6 0.8 3.4 0.4 100 24 99 255 15.6 0.1 16.3 15.2 08/24/2005 08:50:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.7 3.4 0.4 84 35 65 255 16 0.1 16.6 15.7 08/24/2005 09:00:00 1.8 0.6 3 0.4 1.7 0.6 2.6 0.4 1.3 0.7 3 0.4 78 22 76 255 16.7 0 17.1 16.3 08/24/2005 09:10:00 1.7 0.7 3.8 0.4 1.5 0.7 3.8 0.4 1.3 0.7 3 0.4 51 28 51 255 16.9 0 17.4 16.6 08/24/2005 09:20:00 1.7 0.5 3 0.4 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 359 33 49 255 16.2 0.1 16.8 16 08/24/2005 09:30:00 1.7 0.5 3 0.4 1.5 0.5 3 0.4 1 0.6 3 0.4 353 20 342 255 17.1 0.5 18 16.3 08/24/2005 09:40:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 1.2 0.6 2.6 0.4 23 19 9 255 17.2 0.3 17.7 16.6 08/24/2005 09:50:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 44 27 56 255 16.1 0 16.6 15.7 08/24/2005 10:00:00 1.5 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.2 0.5 2.6 0.4 44 23 12 255 15.9 0 16.3 16 08/24/2005 10:10:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 58 26 48 255 16.2 0.2 16.6 16 08/24/2005 10:20:00 2 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.6 0.6 3 0.4 20 12 8 255 16.1 0 16.6 16 08/24/2005 10:30:00 2.3 0.4 3.4 1.1 2.2 0.5 3.4 1.1 1.8 0.6 3 0.4 32 17 52 255 16.3 0.1 16.6 16 08/24/2005 10:40:00 2 0.5 3.4 0.7 2 0.5 3.4 0.7 1.7 0.5 3 0.4 39 14 51 255 16.2 0 16.6 16.3 08/24/2005 10:50:00 2.3 0.6 3.8 0.7 2.3 0.6 3.4 0.7 2.2 0.6 3.4 0.4 34 17 30 255 16.8 0.1 17.4 16.6 08/24/2005 11:00:00 2 0.5 3.4 0.7 1.9 0.5 3.4 0.4 1.6 0.6 3 0.4 28 22 24 255 17.1 0.3 17.7 16.8 08/24/2005 11:10:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.9 0.5 2.3 0.4 31 26 43 255 17.8 0 18 17.7 08/24/2005 11:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 34 22 40 255 18.2 0.2 18.8 17.7 08/24/2005 11:30:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.6 0.5 2.3 0.4 265 86 219 255 18.3 0 18.8 18.2 08/24/2005 11:40:00 1.2 0.7 3.4 0.4 1.2 0.6 3.4 0.4 0.9 0.7 3 0.4 241 49 245 255 18.5 0.2 19.1 18.2 08/24/2005 11:50:00 1 0.7 3 0.4 1 0.7 3 0.4 0.7 0.5 2.6 0.4 65 82 1 255 18.7 0 19.1 18.5 08/24/2005 12:00:00 2.3 0.5 3.8 1.1 2.1 0.4 3.4 1.1 1.9 0.6 3.4 0.4 335 21 321 255 18.5 0.2 19.1 17.7 08/24/2005 12:10:00 1.6 0.6 3 0.4 1.7 0.6 3 0.4 1.1 0.6 2.6 0.4 289 32 293 255 17.6 0.1 18.2 17.4 08/24/2005 12:20:00 1.8 0.5 3 0.4 1.8 0.5 3 0.4 1.4 0.6 2.6 0.4 311 22 294 255 17.5 0.1 18 17.1 08/24/2005 12:30:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 302 13 310 255 17.3 0 18 17.1 08/24/2005 12:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 326 12 333 255 17.6 0.2 18.5 17.1 08/24/2005 12:50:00 1.4 0.9 3.8 0.4 1.4 0.9 3.4 0.4 1.5 0.9 4.2 0.4 118 61 109 255 18.7 0.3 19.7 18.2 08/24/2005 13:00:00 2.7 1 4.9 0.4 2.5 1 4.6 0.4 1.8 1 4.2 0.4 339 53 292 255 19 0.2 19.7 18.5 08/24/2005 13:10:00 1.2 0.9 3.4 0.4 1.2 0.8 3 0.4 1.1 0.8 3 0.4 45 79 329 255 18.3 0 19.1 18 08/24/2005 13:20:00 1.5 1.1 4.6 0.4 1.4 1.1 4.2 0.4 1.1 1 3.8 0.4 316 47 12 255 18.5 0.1 19.4 18.2 08/24/2005 13:30:00 1.5 0.8 4.2 0.4 1.4 0.8 4.2 0.4 0.9 0.7 3.4 0.4 15 18 26 255 19.2 0.1 20 18.8 08/24/2005 13:40:00 1.3 0.7 3 0.4 1.1 0.7 3 0.4 0.7 0.6 2.3 0.4 348 32 4 255 19 0 19.4 18.5 08/24/2005 13:50:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0 35 4 255 18.8 0 19.4 18.5 08/24/2005 14:00:00 0.8 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 352 27 328 255 19.1 0.2 19.4 18.8 08/24/2005 14:10:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 351 21 7 255 19.7 0.4 20.5 19.1 08/24/2005 14:20:00 1.4 1.2 4.6 0.4 1.3 1.2 4.2 0.4 1.1 1 3.8 0.4 17 26 82 255 19.6 0.2 20.3 19.4 08/24/2005 14:30:00 2.5 0.9 4.6 0.4 2.4 0.9 4.2 0.4 2 1 4.2 0.4 10 19 30 255 19.2 0.2 20.3 19.1 08/24/2005 14:40:00 1.8 1.1 3.8 0.4 1.7 1 3.8 0.4 1.3 0.9 3 0.4 359 24 12 255 19.8 0.2 20.5 19.4 08/24/2005 14:50:00 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.4 0.6 2.6 0.4 10 22 8 255 19.4 0 20 19.1 08/24/2005 15:00:00 1.7 0.7 3.8 0.4 1.6 0.7 3.8 0.4 1 0.8 3.4 0.4 9 39 352 255 19.3 0 20 19.1 08/24/2005 15:10:00 1.3 0.8 3 0.4 1.2 0.7 2.6 0.4 0.7 0.6 2.6 0.4 326 45 329 255 19.2 0 20 18.8 08/24/2005 15:20:00 1.3 0.5 3 0.4 1.2 0.6 3 0.4 0.6 0.4 1.9 0.4 352 35 304 255 18.8 0 19.4 18.5 08/24/2005 15:30:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.6 2.6 0.4 335 26 337 255 18.7 0.2 19.1 18.2 08/24/2005 15:40:00 2.9 1.3 6.1 1.1 2.8 1.3 6.1 0.7 2.2 1.3 5.3 0.4 296 14 286 255 18 0.2 18.8 17.4 08/24/2005 15:50:00 3.1 1.3 6.1 0.4 3 1.3 5.7 0.4 2.2 1.3 5.3 0.4 273 27 250 255 17.2 0 17.7 16.8 08/24/2005 16:00:00 2.7 0.9 4.6 0.4 2.6 0.9 4.6 0.4 1.7 0.9 4.6 0.4 267 21 286 255 16.8 0 17.1 16.8 08/24/2005 16:10:00 2.3 0.9 4.6 0.7 2.1 1 4.6 0.4 1.5 0.8 4.2 0.4 274 18 256 255 16.5 0 16.8 16.3 08/24/2005 16:20:00 2 0.6 3.8 0.4 1.8 0.7 3.4 0.4 1.1 0.7 3 0.4 275 19 300 255 16.4 0 16.6 16.3 08/24/2005 16:30:00 1.8 0.6 3.4 0.4 1.6 0.7 3.8 0.4 1 0.6 3 0.4 250 26 276 255 16.4 0 16.8 16.3 08/24/2005 16:40:00 3 0.6 4.2 1.5 2.9 0.6 4.2 1.5 2.1 0.7 3.8 0.4 231 12 239 255 16.4 0.1 16.8 16.3 08/24/2005 16:50:00 2.7 0.8 4.2 0.7 2.7 0.8 4.6 0.4 1.8 0.8 3.8 0.4 233 11 257 255 16.1 0 16.6 16 08/24/2005 17:00:00 2.9 0.8 4.6 1.1 2.7 0.8 4.6 0.4 1.8 0.9 4.2 0.4 224 17 226 255 16 0 16.6 15.7 08/24/2005 17:10:00 2.2 0.6 3.4 0.7 2.1 0.6 3.4 0.4 1.4 0.6 3 0.4 221 19 204 255 16 0 16.6 15.7 08/24/2005 17:20:00 2.3 0.6 3.8 0.4 2.2 0.6 3.4 0.4 1.6 0.7 3 0.4 227 15 232 255 16.1 0 16.6 16 08/24/2005 17:30:00 2.1 0.7 3.8 0.4 1.9 0.7 3.4 0.4 1.2 0.6 2.6 0.4 219 15 205 255 16.1 0 16.8 16 08/24/2005 17:40:00 2.1 0.5 3 1.1 2 0.5 3 0.4 1.2 0.6 3 0.4 237 13 232 255 16 0 16.6 15.7 08/24/2005 17:50:00 1.7 0.6 3.4 0.4 1.6 0.7 3.8 0.4 0.9 0.6 2.6 0.4 253 16 268 255 15.7 0 16.3 15.5 08/24/2005 18:00:00 1.5 0.5 3 0.7 1.2 0.5 2.6 0.4 0.8 0.5 2.6 0.4 283 32 249 255 15.2 0.1 16 14.9 08/24/2005 18:10:00 3.4 1.1 5.7 1.1 2.9 1.1 4.9 0.4 2 1.2 4.9 0.4 338 11 345 255 14.6 0.2 15.5 14.4 08/24/2005 18:20:00 3.7 0.6 4.9 1.9 3.5 0.6 5.3 1.5 2.2 1 4.6 0.4 358 21 336 255 14 0.1 14.6 13.8 08/24/2005 18:30:00 1.8 1.1 4.6 0.4 1.7 1 3.8 0.4 1 0.8 3.8 0.4 44 23 41 255 13.7 0 14.4 13.5 08/24/2005 18:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 47 90 115 255 13.5 0 13.8 13.3 08/24/2005 18:50:00 0.8 0.5 2.3 0.4 0.9 0.5 2.6 0.4 0.6 0.4 2.3 0.4 68 28 85 255 13.3 0 13.8 13 08/24/2005 19:00:00 1.6 0.7 2.6 0.4 1.5 0.7 2.6 0.4 0.9 0.5 2.3 0.4 96 9 92 255 13 0.1 13.5 12.7 08/24/2005 19:10:00 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.2 0.7 3 0.4 137 22 159 255 12.9 0 13.3 12.7 08/24/2005 19:20:00 2.9 0.6 4.2 1.5 3 0.5 3.8 1.1 2.4 0.6 3.4 0.4 165 7 163 255 12.8 0 13.3 12.7 08/24/2005 19:30:00 2.5 0.5 4.2 0.7 3 0.5 4.6 0.7 2 0.7 3.8 0.4 177 13 160 255 12.8 0 13 12.7 08/24/2005 19:40:00 2.3 0.5 3.8 1.1 2.8 0.5 4.2 1.5 1.6 0.6 3 0.4 180 11 153 255 12.7 0 13 12.5 08/24/2005 19:50:00 1.9 0.5 3.4 0.7 2.3 0.5 3.4 0.7 1.4 0.6 3 0.4 177 11 174 255 12.6 0 13 12.5 08/24/2005 20:00:00 1.5 0.5 2.6 0.4 1.7 0.6 3 0.4 0.7 0.5 2.3 0.4 184 12 182 255 12.4 0.1 12.7 12.5 08/24/2005 20:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 182 9 193 255 12.4 0 12.7 12.2 08/24/2005 20:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 177 6 147 255 12.3 0 12.7 12.2 08/24/2005 20:30:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 168 8 168 255 12.3 0 12.7 12.2 08/24/2005 20:40:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 180 6 180 255 12.2 0 12.7 11.9 08/24/2005 20:50:00 1.3 0.3 2.6 0.7 1.4 0.3 2.3 0.7 0.7 0.3 1.9 0.4 175 7 182 255 12.1 0 12.5 11.9 08/24/2005 21:00:00 1.1 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.6 0.4 1.9 0.4 172 9 168 255 12 0 12.2 11.9 08/24/2005 21:10:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 168 6 185 255 12 0 12.2 11.9 08/24/2005 21:20:00 1 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 160 3 167 255 11.9 0 11.9 11.9 08/24/2005 21:30:00 0.7 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 166 6 175 255 11.9 0 11.9 11.7 08/24/2005 21:40:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 164 255 11.8 0 11.9 11.7 08/24/2005 21:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 164 0 164 255 11.7 0 11.9 11.7 08/24/2005 22:00:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 45 64 10 255 11.7 0 11.9 11.7 08/24/2005 22:10:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 345 9 342 255 11.7 0 11.7 11.7 08/24/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.7 0 11.7 11.7 08/24/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.7 0 11.7 11.7 08/24/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.6 0 11.7 11.7 08/24/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.5 0 11.7 11.4 08/24/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.5 0 11.7 11.4 08/24/2005 23:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 342 255 11.5 0 11.7 11.4 08/24/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.4 0 11.7 11.4 08/24/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.3 0 11.4 11.4 08/24/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.3 0 11.4 11.4 08/24/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.3 0 11.4 11.1 08/25/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 255 255 11.3 0 11.4 11.1 08/25/2005 00:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 342 255 11.2 0 11.4 11.1 08/25/2005 00:20:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 0 342 255 11.3 0 11.4 11.4 08/25/2005 00:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 9 342 255 11.3 0 11.4 11.1 08/25/2005 00:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 21 0 21 255 11.4 0 11.4 11.4 08/25/2005 00:50:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 40 22 61 255 11.3 0 11.4 11.4 08/25/2005 01:00:00 1.6 0.2 1.9 1.1 1.1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 86 9 80 255 11.3 0 11.4 11.4 08/25/2005 01:10:00 1.2 0.5 1.9 0.4 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 95 6 106 255 11.3 0 11.4 11.4 08/25/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 255 255 11.3 0 11.4 11.1 08/25/2005 01:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 90 255 11.3 0 11.4 11.1 08/25/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 1 111 255 11.2 0 11.4 11.1 08/25/2005 01:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 90 20 71 255 11.1 0 11.4 11.1 08/25/2005 02:00:00 1.2 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 54 7 56 255 11.1 0 11.4 11.1 08/25/2005 02:10:00 1.6 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.9 0.4 59 9 59 255 11.2 0 11.4 11.1 08/25/2005 02:20:00 1.8 0.5 3 0.4 1.6 0.6 2.6 0.4 0.9 0.5 2.3 0.4 59 10 48 255 11.3 0 11.4 11.1 08/25/2005 02:30:00 2.3 0.6 3.4 0.4 2.1 0.6 3.4 0.7 1.3 0.6 3 0.4 54 9 51 255 11.2 0 11.4 11.1 08/25/2005 02:40:00 1.7 0.6 3.4 0.4 1.4 0.6 3.4 0.4 0.7 0.4 1.9 0.4 56 15 70 255 11.1 0 11.1 11.1 08/25/2005 02:50:00 2.2 0.6 3.4 0.4 2 0.6 3 0.4 1.2 0.7 2.6 0.4 52 10 49 255 11.1 0 11.1 11.1 08/25/2005 03:00:00 2.2 0.7 3.4 0.4 2 0.7 3.4 0.4 1.1 0.7 2.6 0.4 59 15 66 255 11 0 11.1 10.9 08/25/2005 03:10:00 1.7 0.6 3 0.4 1.2 0.7 3 0.4 0.6 0.4 2.6 0.4 53 15 66 255 10.9 0 11.1 10.9 08/25/2005 03:20:00 2.3 0.6 3.4 0.7 2.1 0.7 3.8 0.4 1.4 0.7 2.6 0.4 56 15 57 255 10.7 0 10.9 10.6 08/25/2005 03:30:00 1.6 0.6 3 0.4 1.3 0.6 3 0.4 0.6 0.5 2.3 0.4 57 17 45 255 10.6 0 10.9 10.6 08/25/2005 03:40:00 1.5 0.6 2.6 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 66 18 60 255 10.6 0 10.6 10.6 08/25/2005 03:50:00 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 0.5 0.2 1.5 0.4 53 20 34 255 10.5 0 10.6 10.3 08/25/2005 04:00:00 1.6 0.5 3 0.4 1.2 0.6 2.6 0.4 0.6 0.4 1.9 0.4 72 13 58 255 10.3 0 10.6 10.3 08/25/2005 04:10:00 1.6 0.5 3 0.4 1.3 0.5 3 0.4 0.6 0.4 2.6 0.4 86 10 104 255 10.2 0 10.3 10.3 08/25/2005 04:20:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.6 0.4 2.3 0.4 76 17 97 255 10.2 0 10.3 10.1 08/25/2005 04:30:00 1.8 0.6 3 0.4 1.5 0.6 2.6 0.4 0.8 0.6 2.3 0.4 63 13 48 255 10.2 0 10.3 10.1 08/25/2005 04:40:00 2.2 0.5 3.4 0.7 1.9 0.6 3 0.4 1.1 0.6 3 0.4 61 14 60 255 10.2 0 10.3 10.1 08/25/2005 04:50:00 2 0.5 3 0.4 1.7 0.6 3 0.4 0.6 0.4 1.9 0.4 53 15 52 255 10.1 0 10.3 10.1 08/25/2005 05:00:00 2 0.6 3.8 0.7 1.6 0.7 3.4 0.4 0.9 0.6 3 0.4 58 17 51 255 10.1 0 10.3 10.1 08/25/2005 05:10:00 2 0.6 3.4 0.7 1.5 0.6 3 0.4 0.9 0.5 2.3 0.4 45 12 21 255 10 0 10.3 10.1 08/25/2005 05:20:00 1.9 0.5 3 0.7 1.6 0.5 3 0.4 0.8 0.5 2.3 0.4 44 11 52 255 10 0 10.1 10.1 08/25/2005 05:30:00 1.9 0.6 3.4 0.7 1.6 0.6 3 0.4 0.7 0.5 2.3 0.4 45 11 48 255 10 0 10.3 10.1 08/25/2005 05:40:00 2 0.7 3 0.4 1.7 0.7 3 0.4 0.8 0.4 2.3 0.4 49 9 59 255 10.2 0 10.3 10.1 08/25/2005 05:50:00 0.5 0.3 2.3 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 42 5 48 255 10.2 0 10.3 10.1 08/25/2005 06:00:00 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 66 13 64 255 10.2 0 10.3 10.1 08/25/2005 06:10:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0 0.4 0.4 68 7 62 255 10.2 0 10.3 10.3 08/25/2005 06:20:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 91 22 66 255 10.3 0 10.6 10.3 08/25/2005 06:30:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 4 108 255 10.5 0 10.6 10.3 08/25/2005 06:40:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 110 6 115 255 10.6 0 10.9 10.6 08/25/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 0 255 255 10.7 0 10.9 10.6 08/25/2005 07:00:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 92 15 68 255 11 0 11.1 10.9 08/25/2005 07:10:00 1.5 0.3 2.6 0.7 1.1 0.4 2.3 0.4 0.5 0.2 1.5 0.4 76 8 74 255 11.1 0 11.1 11.1 08/25/2005 07:20:00 1.9 0.4 3 0.7 1.5 0.5 2.6 0.4 0.8 0.5 2.3 0.4 79 9 77 255 11.1 0 11.4 11.1 08/25/2005 07:30:00 2.3 0.4 3.4 1.1 2 0.4 3 0.7 1.2 0.6 2.6 0.4 67 13 63 255 11.1 0 11.4 11.1 08/25/2005 07:40:00 1.9 0.5 3.4 0.7 1.6 0.6 3 0.4 1 0.6 3.4 0.4 65 14 62 255 11.1 0 11.1 11.1 08/25/2005 07:50:00 1.8 0.6 3 0.4 1.4 0.7 3 0.4 0.9 0.6 2.3 0.4 64 15 70 255 11.1 0 11.1 11.1 08/25/2005 08:00:00 1.3 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 67 18 53 255 11.1 0 11.1 11.1 08/25/2005 08:10:00 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 76 9 81 255 11.2 0 11.4 11.1 08/25/2005 08:20:00 1.2 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 40 15 82 255 11.4 0 11.7 11.4 08/25/2005 08:30:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 356 23 340 255 11.7 0 11.9 11.4 08/25/2005 08:40:00 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 354 10 339 255 11.7 0 11.9 11.7 08/25/2005 08:50:00 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 339 19 318 255 11.7 0 11.9 11.7 08/25/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 122 255 255 11.7 0 11.7 11.7 08/25/2005 09:10:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 85 6 80 255 11.6 0 11.7 11.7 08/25/2005 09:20:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 35 41 92 255 11.8 0 11.9 11.7 08/25/2005 09:30:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 355 22 6 255 12 0 12.2 11.9 08/25/2005 09:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 33 342 255 12.3 0 12.5 12.2 08/25/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 0 255 255 12.4 0 12.5 12.2 08/25/2005 10:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 353 32 38 255 12.7 0 12.7 12.5 08/25/2005 10:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 27 310 255 12.7 0 12.7 12.5 08/25/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 19 255 255 12.9 0 13 12.7 08/25/2005 10:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 241 22 270 255 13.4 0 14.1 13 08/25/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 255 255 13.7 0 14.4 13.5 08/25/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 0 255 255 13.9 0 14.6 13.8 08/25/2005 11:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 71 102 7 255 13.9 0.1 14.4 13.8 08/25/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 0 255 255 13.9 0.1 14.6 13.8 08/25/2005 11:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 242 38 231 255 14.2 0.1 14.6 14.1 08/25/2005 11:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 137 90 166 255 14.1 0.1 14.6 13.8 08/25/2005 11:40:00 0.5 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 191 69 129 255 13.9 0 14.4 13.8 08/25/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 100 0 255 255 13.8 0 14.4 13.5 08/25/2005 12:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 56 41 16 255 14 0.2 14.6 13.8 08/25/2005 12:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1 21 12 255 14.6 0.3 15.7 14.1 08/25/2005 12:20:00 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 10 22 19 255 15.5 0.1 16 15.2 08/25/2005 12:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 14 20 354 255 15.1 0 15.7 15.2 08/25/2005 12:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 358 64 318 255 15.4 0.1 16 15.2 08/25/2005 12:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 320 36 291 255 14.9 0 15.5 14.6 08/25/2005 13:00:00 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.5 2.3 0.4 359 27 335 255 14.6 0 14.9 14.6 08/25/2005 13:10:00 1.2 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 341 3 342 255 14.5 0 14.9 14.4 08/25/2005 13:20:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 343 6 347 255 14.3 0.1 14.6 14.1 08/25/2005 13:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 5 11 255 14.4 0 14.9 14.1 08/25/2005 13:40:00 1.1 0.5 2.3 0.4 0.8 0.5 2.6 0.4 0.5 0.3 1.9 0.4 13 9 22 255 14.6 0.1 15.2 14.4 08/25/2005 13:50:00 0.8 0.5 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 346 24 279 255 14.9 0.1 15.7 14.6 08/25/2005 14:00:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 307 12 305 255 15.4 0.1 16 15.2 08/25/2005 14:10:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 334 28 316 255 15.2 0.1 15.7 15.2 08/25/2005 14:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 2 0 2 255 15 0 15.7 14.9 08/25/2005 14:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 353 22 2 255 14.8 0 15.2 14.9 08/25/2005 14:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 301 10 356 255 15 0 15.5 14.9 08/25/2005 14:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 320 28 264 255 15.2 0 15.7 15.2 08/25/2005 15:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 228 22 256 255 15.7 0.2 16.3 15.5 08/25/2005 15:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 189 24 214 255 16.3 0.1 16.8 16.3 08/25/2005 15:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 182 66 181 255 15.9 0.1 16.8 15.7 08/25/2005 15:30:00 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 1 0.5 2.6 0.4 165 7 171 255 15.4 0.2 16 15.2 08/25/2005 15:40:00 1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 156 41 165 255 15.3 0 15.7 15.2 08/25/2005 15:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 104 56 79 255 15.5 0 16 15.2 08/25/2005 16:00:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 113 23 118 255 15.7 0 16.3 15.7 08/25/2005 16:10:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.5 2.3 0.4 104 39 64 255 15.9 0 16.3 15.7 08/25/2005 16:20:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 125 23 140 255 15.7 0 16.3 15.7 08/25/2005 16:30:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 117 32 42 255 15.6 0 16 15.5 08/25/2005 16:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.9 0.4 50 17 94 255 15.5 0 16 15.5 08/25/2005 16:50:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 85 19 106 255 15.6 0 16 15.5 08/25/2005 17:00:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 64 43 101 255 15.9 0 16.3 15.7 08/25/2005 17:10:00 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.6 0.5 2.3 0.4 68 47 12 255 16.1 0.1 16.8 16 08/25/2005 17:20:00 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.5 2.6 0.4 39 21 35 255 16.1 0 16.8 16 08/25/2005 17:30:00 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 58 22 49 255 16.1 0 16.3 16 08/25/2005 17:40:00 1.6 0.4 2.6 0.7 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 58 28 40 255 15.9 0 16.3 15.7 08/25/2005 17:50:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 78 6 90 255 15.6 0 15.7 15.5 08/25/2005 18:00:00 1.3 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 75 15 76 255 15.5 0 15.7 15.5 08/25/2005 18:10:00 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 59 12 66 255 15.4 0 15.7 15.2 08/25/2005 18:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 52 3 57 255 15 0 15.7 14.9 08/25/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 47 255 255 14.6 0 15.2 14.4 08/25/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 316 0 255 255 14.2 0.1 14.9 14.1 08/25/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 316 0 255 255 14 0 14.6 13.8 08/25/2005 19:00:00 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 48 45 69 255 13.9 0 14.4 13.8 08/25/2005 19:10:00 1 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 1 69 255 13.6 0.1 14.1 13.3 08/25/2005 19:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 0 88 255 13.1 0.2 13.8 12.7 08/25/2005 19:30:00 0.7 0.5 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 98 7 104 255 12.7 0.1 13.3 12.5 08/25/2005 19:40:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 47 64 104 255 12.3 0 12.7 11.9 08/25/2005 19:50:00 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 14 12 4 255 11.9 0.1 12.5 11.7 08/25/2005 20:00:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 36 22 255 11.9 0 11.9 11.7 08/25/2005 20:10:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 295 16 275 255 12 0 12.2 11.9 08/25/2005 20:20:00 2.1 0.5 3.4 0.7 1.7 0.6 3.4 0.4 0.7 0.5 3 0.4 271 10 268 255 12 0 12.2 11.9 08/25/2005 20:30:00 3 0.9 5.3 1.1 2.8 0.9 5.3 0.7 2.1 0.9 4.9 0.4 280 19 290 255 12.1 0 12.5 11.9 08/25/2005 20:40:00 2.6 1 4.9 0.4 2.4 1 4.9 0.4 1.6 1 3.8 0.4 285 22 282 255 12.3 0 12.5 12.2 08/25/2005 20:50:00 2.6 0.7 4.9 0.7 2.3 0.8 4.9 0.4 1.5 0.8 3.8 0.4 283 18 303 255 12.1 0 12.2 11.9 08/25/2005 21:00:00 2.3 0.6 3.8 0.4 2 0.8 4.2 0.4 1.4 0.7 3 0.4 278 16 263 255 11.8 0.1 12.2 11.7 08/25/2005 21:10:00 2.2 0.5 3.4 0.7 2 0.5 3.4 0.7 1 0.6 2.6 0.4 279 17 291 255 11.5 0 11.7 11.4 08/25/2005 21:20:00 1.7 0.5 3 0.4 1.3 0.6 3 0.4 0.6 0.4 1.9 0.4 278 13 273 255 11.3 0 11.7 11.1 08/25/2005 21:30:00 1.6 0.5 2.6 0.7 1.1 0.6 2.6 0.4 0.5 0.4 2.3 0.4 259 8 262 255 11.1 0 11.4 11.1 08/25/2005 21:40:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 264 7 264 255 11.1 0 11.4 11.1 08/25/2005 21:50:00 1.5 0.4 2.3 0.7 1.1 0.5 1.9 0.4 0.4 0 0.7 0.4 248 5 243 255 11.1 0 11.1 11.1 08/25/2005 22:00:00 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 230 8 247 255 11.1 0 11.1 10.9 08/25/2005 22:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 320 53 11 255 11 0 11.1 10.9 08/25/2005 22:20:00 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 14 4 14 255 11 0 11.1 10.9 08/25/2005 22:30:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 323 0 323 255 11.1 0 11.1 11.1 08/25/2005 22:40:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 323 0 323 255 11.1 0 11.1 11.1 08/25/2005 22:50:00 1.9 0.4 2.6 0.7 1.6 0.5 2.6 0.4 0.7 0.4 1.9 0.4 285 20 284 255 11.1 0 11.4 11.1 08/25/2005 23:00:00 2.1 0.5 3 1.1 1.7 0.5 2.6 0.4 0.7 0.5 1.9 0.4 253 13 252 255 11.2 0 11.4 11.1 08/25/2005 23:10:00 1 0.6 2.3 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 285 45 240 255 11.3 0 11.4 11.1 08/25/2005 23:20:00 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 3 0 3 255 11.3 0 11.4 11.1 08/25/2005 23:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 3 0 3 255 11.1 0 11.4 11.1 08/25/2005 23:40:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 3 255 11.1 0 11.1 11.1 08/25/2005 23:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 3 255 11.1 0 11.1 11.1 08/26/2005 00:00:00 1.3 0.5 2.3 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 339 16 334 255 11.1 0 11.1 11.1 08/26/2005 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 0 327 255 11.1 0 11.1 11.1 08/26/2005 00:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 0 327 255 10.9 0 11.1 10.9 08/26/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 94 255 255 10.9 0 10.9 10.9 08/26/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 255 255 10.7 0 10.9 10.6 08/26/2005 00:50:00 1.2 0.3 1.9 0.4 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 117 17 133 255 10.6 0 10.9 10.6 08/26/2005 01:00:00 1.2 0.3 1.9 0.7 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 132 0 133 255 10.5 0 10.6 10.3 08/26/2005 01:10:00 1.2 0.3 1.9 0.4 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 126 11 133 255 10.3 0 10.6 10.3 08/26/2005 01:20:00 1 0.6 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 107 4 105 255 10.3 0 10.6 10.1 08/26/2005 01:30:00 1.5 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.5 0.3 1.5 0.4 113 8 99 255 10.1 0 10.3 10.1 08/26/2005 01:40:00 1.6 0.6 2.6 0.4 1.2 0.5 2.3 0.4 0.4 0.2 1.5 0.4 103 7 98 255 10.2 0 10.3 10.1 08/26/2005 01:50:00 1.9 0.4 2.6 0.7 1.5 0.4 2.3 0.4 0.5 0.3 1.5 0.4 100 8 96 255 10.1 0 10.3 10.1 08/26/2005 02:00:00 1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0 0.7 0.4 99 3 95 255 10.3 0 10.6 10.1 08/26/2005 02:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 100 255 10.4 0 10.6 10.3 08/26/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 0 255 255 10.4 0 10.6 10.3 08/26/2005 02:30:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 35 170 255 10.5 0 10.6 10.3 08/26/2005 02:40:00 1.2 0.3 1.5 0.7 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 159 9 170 255 10.5 0 10.6 10.3 08/26/2005 02:50:00 1.4 0.3 2.3 0.7 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 133 12 125 255 10.3 0 10.6 10.3 08/26/2005 03:00:00 1.9 0.3 2.6 1.1 1.5 0.4 2.3 0.4 1.1 0.4 2.3 0.4 131 6 127 255 10.2 0 10.3 10.1 08/26/2005 03:10:00 2.1 0.4 2.6 1.1 1.8 0.4 2.6 0.7 1.4 0.4 2.3 0.4 126 9 129 255 10.2 0 10.3 10.1 08/26/2005 03:20:00 2.2 0.4 3.4 0.7 2 0.4 3 0.7 1.1 0.4 2.6 0.4 121 6 116 255 10.2 0 10.3 10.1 08/26/2005 03:30:00 1.9 0.6 3.4 0.4 1.7 0.6 2.6 0.4 0.6 0.4 1.9 0.4 111 16 111 255 10 0 10.3 9.8 08/26/2005 03:40:00 1.7 0.5 3 0.4 1.5 0.5 3 0.4 0.6 0.4 2.3 0.4 109 12 101 255 9.9 0 10.1 9.6 08/26/2005 03:50:00 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1 0.6 2.6 0.4 119 10 121 255 9.6 0.1 9.8 9.6 08/26/2005 04:00:00 2 0.6 3.4 0.4 1.8 0.6 3 0.4 1.2 0.6 2.6 0.4 125 12 118 255 9.6 0 9.6 9.6 08/26/2005 04:10:00 1.8 0.6 3 0.4 1.5 0.6 2.6 0.4 0.7 0.5 1.9 0.4 110 17 112 255 9.6 0 9.8 9.3 08/26/2005 04:20:00 1.7 0.9 3.8 0.4 1.5 0.9 3.8 0.4 0.6 0.5 3 0.4 101 20 105 255 9.4 0 9.6 9.3 08/26/2005 04:30:00 2.4 0.6 3.8 0.7 2.1 0.6 3.4 0.7 0.9 0.5 2.6 0.4 114 13 118 255 9.4 0 9.6 9.3 08/26/2005 04:40:00 2.2 0.4 3 1.1 1.9 0.5 3 0.4 1 0.6 2.6 0.4 113 10 124 255 9.6 0 9.6 9.6 08/26/2005 04:50:00 1.8 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.5 0.3 1.5 0.4 109 11 133 255 9.4 0 9.6 9 08/26/2005 05:00:00 1.8 0.3 2.3 0.7 1.5 0.4 2.3 0.4 0.4 0.2 1.1 0.4 99 6 90 255 9 0 9.3 8.8 08/26/2005 05:10:00 1.9 0.3 2.6 1.1 1.5 0.4 2.3 0.7 0.4 0.1 1.1 0.4 107 7 99 255 8.5 0.1 8.8 8.5 08/26/2005 05:20:00 1.6 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.4 0.1 1.1 0.4 102 7 119 255 8.3 0 8.5 8.3 08/26/2005 05:30:00 2.2 0.4 3 1.1 1.8 0.4 2.6 0.4 0.7 0.4 1.9 0.4 111 9 107 255 8.1 0.1 8.5 7.8 08/26/2005 05:40:00 1.9 0.5 3 0.7 1.6 0.5 3 0.4 1 0.5 2.3 0.4 124 10 133 255 7.7 0 7.8 7.5 08/26/2005 05:50:00 2.2 0.4 3.4 0.7 1.9 0.5 3 0.7 1.3 0.4 2.6 0.4 127 9 152 255 7.4 0 7.5 7.3 08/26/2005 06:00:00 2.3 0.4 3.4 1.1 2 0.5 3 0.7 1.3 0.5 2.3 0.4 129 8 112 255 7.4 0 7.5 7.3 08/26/2005 06:10:00 2.2 0.4 3 1.1 1.9 0.4 3 0.7 1.2 0.6 2.6 0.4 131 10 133 255 7.3 0 7.5 7.3 08/26/2005 06:20:00 2.6 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.4 0.5 2.6 0.4 128 10 121 255 7.3 0 7.3 7.3 08/26/2005 06:30:00 2.3 0.5 3.4 1.1 1.9 0.6 3.4 0.7 1.2 0.5 2.3 0.4 127 11 105 255 7.3 0 7.3 7.3 08/26/2005 06:40:00 1.9 0.5 3.4 0.7 1.5 0.6 3 0.4 0.8 0.5 2.3 0.4 129 10 115 255 7.4 0 7.5 7.3 08/26/2005 06:50:00 1.8 0.4 3 0.7 1.4 0.5 2.6 0.4 0.5 0.3 1.9 0.4 133 9 137 255 7.5 0 7.8 7.5 08/26/2005 07:00:00 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 113 7 126 255 8.1 0.3 8.8 7.8 08/26/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 110 0 255 255 9.2 0 9.3 8.8 08/26/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 13 255 255 9.8 0.2 10.3 9.3 08/26/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 0 255 255 10.6 0.1 10.9 10.3 08/26/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 79 0 255 255 11.1 0 11.1 10.9 08/26/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 79 0 255 255 11.2 0 11.7 10.9 08/26/2005 08:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 79 0 80 255 12.1 0.1 12.5 11.7 08/26/2005 08:10:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 59 29 80 255 12.7 0.1 13 12.5 08/26/2005 08:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 14 5 19 255 13.3 0.2 14.1 12.7 08/26/2005 08:30:00 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 4 7 357 255 13.9 0.1 14.6 13.8 08/26/2005 08:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 10 12 14 255 14 0 14.6 13.8 08/26/2005 08:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 10 11 9 255 13.9 0 14.9 13.5 08/26/2005 09:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 25 22 14 255 14.5 0 15.2 14.4 08/26/2005 09:10:00 0.9 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.9 0.5 2.3 0.4 3 13 22 255 14.7 0.2 15.2 14.4 08/26/2005 09:20:00 1.8 0.4 3 0.4 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 27 22 7 255 14.8 0.2 15.5 14.1 08/26/2005 09:30:00 1.5 0.6 3.4 0.4 1.3 0.6 3 0.4 1 0.6 2.3 0.4 10 35 34 255 14.4 0.2 14.9 14.1 08/26/2005 09:40:00 1.8 0.6 3.4 0.4 1.6 0.7 3 0.4 1.2 0.7 3 0.4 316 22 326 255 14.4 0.1 14.9 13.8 08/26/2005 09:50:00 2 0.7 3.4 0.4 1.8 0.8 3.4 0.4 1.4 0.6 2.6 0.4 306 32 308 255 14.4 0.2 15.2 14.1 08/26/2005 10:00:00 1.6 0.9 3.4 0.4 1.5 0.8 3.4 0.4 1.2 0.7 3 0.4 289 36 310 255 14.9 0.2 15.7 14.4 08/26/2005 10:10:00 2.3 0.6 3.8 0.4 2.1 0.7 3.8 0.4 1.6 0.7 3.4 0.4 306 26 286 255 15.7 0.3 16.3 15.2 08/26/2005 10:20:00 2 0.7 3.4 0.4 1.8 0.8 3.4 0.4 1.4 1 3.4 0.4 309 27 304 255 16.1 0.1 16.8 16 08/26/2005 10:30:00 2.8 0.6 4.2 0.7 2.6 0.7 4.2 1.1 2.2 1 4.2 0.4 306 16 306 255 15.3 0.3 16 14.9 08/26/2005 10:40:00 2.4 0.5 3.8 0.4 2.3 0.5 3.4 0.4 1.7 0.7 3.4 0.4 304 18 311 255 15 0 15.2 14.9 08/26/2005 10:50:00 2.5 0.7 4.2 0.4 2.3 0.7 4.2 0.4 1.9 0.8 3.8 0.4 302 19 272 255 14.8 0.1 15.2 14.6 08/26/2005 11:00:00 3.2 0.5 4.6 1.9 3.1 0.6 4.6 1.5 2.5 0.7 4.2 0.7 309 12 320 255 14.8 0.2 15.5 14.6 08/26/2005 11:10:00 3.3 0.8 4.9 1.5 3.1 0.9 5.3 1.1 2.6 1 4.6 0.4 301 18 285 255 15.4 0 15.7 15.2 08/26/2005 11:20:00 3 1.1 5.7 0.4 2.9 1.1 5.3 0.4 2.1 1.3 5.3 0.4 270 29 248 255 16.1 0.2 16.6 15.7 08/26/2005 11:30:00 3.3 1.2 6.5 0.4 3.2 1.2 6.1 0.4 2.4 1.1 5.7 0.4 274 28 302 255 15.7 0 16 15.5 08/26/2005 11:40:00 3.2 1 5.7 1.1 3.1 1 5.3 0.4 2.5 1 5.3 0.4 288 22 258 255 15.7 0 16 15.5 08/26/2005 11:50:00 3.1 1.3 6.5 0.4 2.9 1.4 6.5 0.4 2.4 1.2 5.3 0.4 284 32 271 255 15.9 0.3 16.6 15.7 08/26/2005 12:00:00 2.8 1.3 5.7 0.4 2.6 1.4 5.7 0.4 2 1.3 5.7 0.4 266 41 281 255 17 0.2 17.4 16.6 08/26/2005 12:10:00 3.5 1 6.1 0.4 3.4 1 5.7 0.4 2.9 1 5.7 0.4 280 32 284 255 16.6 0 17.1 16.6 08/26/2005 12:20:00 2.9 1.1 6.8 0.7 2.8 1.2 6.5 0.4 2.2 1.1 5.7 0.4 275 41 300 255 17.5 0.6 18.2 16.6 08/26/2005 12:30:00 3.3 1.5 5.7 0.4 3.2 1.5 5.7 0.4 2.7 1.5 6.1 0.4 253 19 264 255 17 0.6 18.2 16.3 08/26/2005 12:40:00 3.2 0.7 4.9 1.5 3 0.9 4.9 0.4 2.3 0.8 4.6 0.4 232 21 238 255 16 0 16.8 16 08/26/2005 12:50:00 2.7 0.9 4.6 0.4 2.5 1 4.6 0.4 1.8 1 4.2 0.4 251 24 263 255 16 0 16.3 15.7 08/26/2005 13:00:00 2.3 0.7 3.8 0.4 2 0.8 3.8 0.4 1.4 0.8 3.4 0.4 242 19 265 255 16 0 16.3 16 08/26/2005 13:10:00 2.1 0.8 4.6 0.4 1.9 0.8 4.6 0.4 1.5 0.8 3.8 0.4 265 26 256 255 16.1 0 16.3 16 08/26/2005 13:20:00 2 0.8 4.2 0.4 1.6 0.9 4.2 0.4 1.2 0.8 3.8 0.4 277 47 240 255 16.2 0 16.6 16 08/26/2005 13:30:00 2.8 1 5.7 1.1 2.5 1 5.7 0.4 1.9 1 4.6 0.4 310 20 282 255 16.6 0 16.8 16.6 08/26/2005 13:40:00 2.7 1 4.9 0.7 2.5 1 4.9 0.4 2.1 1.1 4.6 0.4 283 45 319 255 16.8 0.2 17.4 16.6 08/26/2005 13:50:00 3.8 1.2 6.5 0.4 3.7 1.2 6.1 0.4 2.7 1.1 5.3 0.4 196 32 191 255 16.6 0.9 17.7 15.2 08/26/2005 14:00:00 3.2 1.1 5.3 1.1 3.1 1.2 5.7 0.7 2.2 1 4.6 0.7 224 10 223 255 14.7 0.1 15.2 14.6 08/26/2005 14:10:00 1.3 0.3 2.6 0.4 1.1 0.4 2.3 0.4 0.5 0.2 1.1 0.4 234 8 221 255 14.8 0.1 15.5 14.6 08/26/2005 14:20:00 1.9 0.8 4.2 0.4 1.8 0.8 3.8 0.4 1 0.8 3.4 0.4 223 21 226 255 15.3 0 16 15.2 08/26/2005 14:30:00 2.4 0.6 4.2 0.7 2.2 0.7 4.2 0.4 1.6 0.8 3.8 0.4 221 17 221 255 15 0.2 16 14.6 08/26/2005 14:40:00 3 0.5 4.2 1.9 2.9 0.6 4.2 1.5 1.8 0.6 3.4 0.4 249 11 277 255 14.2 0.2 15.2 13.8 08/26/2005 14:50:00 2.6 0.8 4.6 0.7 2.4 0.9 4.6 0.4 1.4 0.8 3.4 0.4 261 17 255 255 13.6 0.1 14.4 13.3 08/26/2005 15:00:00 2.5 0.6 4.2 1.1 2.4 0.6 4.2 0.7 1.2 0.8 3.4 0.4 253 15 251 255 13.1 0.2 13.8 12.7 08/26/2005 15:10:00 1.7 0.5 3.4 0.7 1.5 0.6 3 0.4 0.6 0.4 1.9 0.4 273 13 287 255 12.8 0 13.3 12.7 08/26/2005 15:20:00 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 280 12 281 255 12.6 0 12.7 12.5 08/26/2005 15:30:00 2 0.5 3 0.4 1.8 0.6 3.4 0.4 0.6 0.4 1.9 0.4 265 11 256 255 12.5 0 12.7 12.5 08/26/2005 15:40:00 2.6 0.7 4.2 1.1 2.4 0.7 4.2 0.4 1.1 0.6 3.4 0.4 259 13 245 255 12.6 0 13 12.5 08/26/2005 15:50:00 2.8 0.7 4.6 1.1 2.6 0.7 4.2 0.4 1.2 0.6 3 0.4 273 18 286 255 12.9 0 13.5 12.7 08/26/2005 16:00:00 1.6 0.8 3.8 0.4 1.3 0.8 3.8 0.4 0.7 0.5 3 0.4 324 35 290 255 13.3 0 13.8 13 08/26/2005 16:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 74 33 19 255 13.7 0 14.4 13.5 08/26/2005 16:20:00 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 72 58 314 255 14 0.1 14.6 13.8 08/26/2005 16:30:00 1.4 0.6 2.6 0.4 1.1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 311 11 318 255 14.2 0 14.9 14.1 08/26/2005 16:40:00 1.2 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.5 3 0.4 300 19 332 255 14.5 0 15.2 14.4 08/26/2005 16:50:00 1.9 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.2 0.8 3.4 0.4 279 22 303 255 14.5 0 14.9 14.4 08/26/2005 17:00:00 1.8 0.6 3.4 0.4 1.5 0.7 3.8 0.4 1 0.7 2.6 0.4 289 20 279 255 14.4 0 14.9 14.4 08/26/2005 17:10:00 1.1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 304 16 268 255 14.2 0 14.9 14.4 08/26/2005 17:20:00 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 319 26 280 255 14.2 0 14.6 14.1 08/26/2005 17:30:00 2.4 0.6 3.4 0.7 2.2 0.6 3.4 0.7 2 0.6 3.4 0.4 295 13 302 255 14.1 0 14.6 13.8 08/26/2005 17:40:00 2.5 0.6 3.8 1.1 2.3 0.6 3.8 0.7 2 0.7 4.2 0.4 293 16 252 255 14.1 0 14.6 13.8 08/26/2005 17:50:00 1.7 1 4.2 0.4 1.4 1 4.2 0.4 1.2 0.8 3.8 0.4 291 17 308 255 14.1 0.1 14.6 13.8 08/26/2005 18:00:00 2.2 1.3 4.6 0.4 2 1.4 4.6 0.4 1.7 1.3 4.9 0.4 299 17 290 255 14.4 0.2 15.2 14.1 08/26/2005 18:10:00 1.6 0.7 3 0.4 1.3 0.7 3 0.4 1.1 0.8 3 0.4 304 9 307 255 14.6 0 15.2 14.6 08/26/2005 18:20:00 1.4 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 307 14 295 255 14.6 0.1 15.2 14.6 08/26/2005 18:30:00 1.9 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1.1 0.7 3.4 0.4 287 16 281 255 14.4 0 15.2 14.1 08/26/2005 18:40:00 1.2 0.9 3 0.4 1 0.8 3.4 0.4 0.7 0.6 3 0.4 272 11 248 255 13.9 0 14.6 13.5 08/26/2005 18:50:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 290 26 319 255 13.4 0.1 14.1 13 08/26/2005 19:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 319 0 319 255 12.8 0 13.5 12.5 08/26/2005 19:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 319 0 319 255 12.4 0 12.7 12.2 08/26/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 319 0 255 255 12.1 0 12.2 11.9 08/26/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 319 0 255 255 11.7 0 11.9 11.7 08/26/2005 19:40:00 0.9 0.8 2.6 0.4 0.8 0.7 2.6 0.4 0.9 0.6 2.3 0.4 268 79 153 255 11.5 0 11.7 11.4 08/26/2005 19:50:00 1.6 0.5 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.6 1.9 0.4 137 4 129 255 11.2 0 11.4 11.1 08/26/2005 20:00:00 1.2 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 150 13 164 255 11.2 0 11.4 11.1 08/26/2005 20:10:00 2.2 0.4 3.4 1.5 2.2 0.4 3 1.1 1.6 0.4 2.6 0.7 161 15 153 255 11.3 0 11.4 11.1 08/26/2005 20:20:00 3 0.6 4.9 1.5 2.8 0.7 4.9 1.1 2.1 0.6 4.6 0.4 132 14 131 255 11.2 0 11.4 11.1 08/26/2005 20:30:00 3.3 0.6 4.9 1.9 3.1 0.6 4.9 1.9 2.1 0.6 4.2 0.7 119 15 126 255 11.3 0 11.7 11.1 08/26/2005 20:40:00 3.6 0.6 5.3 2.3 3.5 0.7 5.3 1.9 2.2 0.7 4.2 0.4 115 15 105 255 11.7 0 11.7 11.4 08/26/2005 20:50:00 3.1 0.9 5.3 0.7 3 1 4.9 0.7 1.9 0.8 3.8 0.4 112 19 112 255 11.7 0 11.7 11.7 08/26/2005 21:00:00 3.2 0.8 5.3 0.7 3 0.8 6.1 1.1 2.1 0.9 5.3 0.4 116 16 81 255 11.6 0 11.7 11.7 08/26/2005 21:10:00 3.3 0.6 4.9 1.5 3.2 0.6 4.6 1.5 2.3 0.8 4.6 0.4 124 16 121 255 11.4 0.1 11.7 11.1 08/26/2005 21:20:00 3.2 0.7 4.9 1.5 3 0.7 5.3 1.1 2.1 0.7 4.2 0.4 135 15 124 255 11.3 0 11.7 11.1 08/26/2005 21:30:00 2.6 0.7 4.6 1.1 2.4 0.7 4.2 0.7 1.7 0.8 3.4 0.4 151 20 139 255 11.1 0 11.4 10.9 08/26/2005 21:40:00 2.7 0.5 4.2 1.5 2.7 0.4 3.4 1.5 1.6 0.5 3 0.4 192 12 184 255 10.3 0.2 10.9 10.1 08/26/2005 21:50:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.8 0.6 3 0.4 170 14 180 255 9.8 0.1 10.1 9.6 08/26/2005 22:00:00 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.5 1.6 0.6 3 0.4 164 8 151 255 9.4 0 9.6 9.3 08/26/2005 22:10:00 2.9 0.5 4.2 1.9 2.7 0.4 4.2 1.5 2 0.5 3.4 0.7 163 8 167 255 9.2 0 9.3 9 08/26/2005 22:20:00 2.2 1.1 4.6 0.4 2.1 1 3.8 0.4 1.5 1 3.8 0.4 139 36 158 255 9.5 0 9.6 9.3 08/26/2005 22:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 52 86 244 255 9.4 0 9.6 9 08/26/2005 22:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 214 29 148 255 9 0 9.3 8.8 08/26/2005 22:50:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.4 1.9 0.4 162 33 219 255 8.7 0.1 9 8.5 08/26/2005 23:00:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 155 35 198 255 8.5 0 8.8 8.5 08/26/2005 23:10:00 2.6 0.6 4.2 1.5 2.5 0.6 4.2 1.1 1.7 0.5 3.8 0.4 139 23 135 255 8.1 0.1 8.5 7.8 08/26/2005 23:20:00 3.5 0.8 5.7 1.9 3.4 0.9 6.1 1.5 2.1 0.8 5.3 0.4 107 15 97 255 8.3 0.2 8.8 7.8 08/26/2005 23:30:00 2.8 1 5.3 0.7 2.6 1 5.3 0.4 1.7 0.9 4.2 0.4 124 17 143 255 8.6 0.1 9 8.5 08/26/2005 23:40:00 4 1 6.8 1.9 3.8 1 6.5 1.5 3 0.8 5.3 1.1 118 16 111 255 10 0.5 10.6 9 08/26/2005 23:50:00 3.8 0.8 6.1 1.9 3.7 0.8 5.7 1.9 2.8 0.8 4.9 1.1 122 13 115 255 10.5 0 10.6 10.3 08/27/2005 00:00:00 3.6 0.7 5.3 1.9 3.5 0.7 5.3 1.9 2.5 0.7 4.2 0.7 124 15 129 255 10.2 0 10.6 10.1 08/27/2005 00:10:00 4.1 1 6.5 1.9 4 1 6.5 1.9 2.8 0.9 5.3 0.4 121 16 113 255 10.2 0 10.3 10.1 08/27/2005 00:20:00 3.3 0.6 4.9 1.9 3.2 0.6 5.3 1.9 2.3 0.7 4.6 0.7 134 13 137 255 10.1 0.1 10.6 9.8 08/27/2005 00:30:00 3.5 0.6 5.3 1.5 3.4 0.6 4.6 1.9 2.1 0.7 3.8 0.4 120 13 145 255 9.6 0.1 9.8 9.3 08/27/2005 00:40:00 3.6 0.6 5.3 2.3 3.4 0.6 5.3 1.9 2.4 0.7 4.2 0.7 128 13 108 255 9.4 0 9.6 9.3 08/27/2005 00:50:00 3.9 0.6 5.3 2.3 3.7 0.6 4.9 2.3 2.7 0.6 4.6 1.1 144 11 158 255 9.3 0 9.6 9.3 08/27/2005 01:00:00 4.1 0.6 5.7 2.3 3.9 0.5 5.3 2.3 2.9 0.6 4.9 1.1 153 11 142 255 9.5 0 9.6 9.3 08/27/2005 01:10:00 4.4 0.7 6.1 2.6 4.2 0.6 5.7 2.6 3 0.8 5.3 0.7 155 12 148 255 9.5 0 9.6 9.6 08/27/2005 01:20:00 4.1 0.7 6.1 2.3 4.1 0.6 6.1 2.3 3.1 0.6 4.9 1.5 161 10 153 255 9.5 0 9.6 9.3 08/27/2005 01:30:00 4.3 0.8 6.5 2.3 4.2 0.8 6.5 2.3 3.2 0.8 5.3 1.5 138 14 146 255 9.4 0 9.6 9 08/27/2005 01:40:00 4.2 0.7 6.1 1.9 4.2 0.7 6.1 1.9 3.1 0.8 4.9 1.5 142 15 127 255 9.7 0.1 10.1 9.3 08/27/2005 01:50:00 3.6 0.8 5.7 1.9 3.8 0.7 5.3 1.9 2.9 0.8 5.3 1.1 175 20 150 255 10 0.1 10.3 9.6 08/27/2005 02:00:00 4.5 0.7 6.5 2.6 4.6 0.7 6.5 2.6 3 0.8 5.3 1.1 216 12 236 255 8.7 0.4 9.6 8.3 08/27/2005 02:10:00 3.4 0.9 4.9 1.1 3.4 0.8 4.9 1.1 2.3 0.7 4.2 0.4 201 22 209 255 8 0.1 8.3 7.8 08/27/2005 02:20:00 1.8 0.5 3.4 0.7 2.2 0.6 3.4 0.4 1.2 0.6 2.6 0.4 178 12 191 255 7.8 0 7.8 7.8 08/27/2005 02:30:00 0.9 0.3 1.9 0.4 0.8 0.3 1.9 0.4 0.4 0.1 1.1 0.4 177 30 164 255 7.7 0 7.8 7.5 08/27/2005 02:40:00 0.6 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 222 0 222 255 7.5 0.1 7.8 7.3 08/27/2005 02:50:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 304 45 304 255 7.4 0 7.5 7.3 08/27/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 278 16 255 255 7.3 0 7.5 7.3 08/27/2005 03:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 157 41 152 255 7.3 0 7.5 7.3 08/27/2005 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 91 0 91 255 7.2 0 7.3 7 08/27/2005 03:30:00 1.4 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1 0.8 3 0.4 267 79 271 255 7 0 7.3 7 08/27/2005 03:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 142 26 119 255 6.7 0 7 6.5 08/27/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 132 1 255 255 6.5 0.1 6.7 6.2 08/27/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 133 0 255 255 6.1 0 6.5 6 08/27/2005 04:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 133 0 133 255 6 0 6 5.7 08/27/2005 04:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 164 33 203 255 5.7 0 6 5.7 08/27/2005 04:30:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 132 33 207 255 5.6 0 5.7 5.5 08/27/2005 04:40:00 1.4 0.8 2.6 0.4 1.1 0.8 2.3 0.4 0.7 0.5 2.3 0.4 231 13 250 255 5.3 0.1 5.7 5 08/27/2005 04:50:00 1.4 0.4 2.6 0.4 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 202 21 212 255 5.3 0 5.5 5 08/27/2005 05:00:00 1.6 0.4 2.3 0.7 1.5 0.5 2.3 0.4 1.2 0.6 2.3 0.4 173 11 168 255 5.2 0 5.5 5 08/27/2005 05:10:00 1.6 0.5 2.6 0.4 1.4 0.6 2.3 0.4 0.8 0.4 1.9 0.4 157 29 155 255 5 0 5.2 5 08/27/2005 05:20:00 1.5 0.5 2.6 0.4 1.2 0.4 2.3 0.4 0.5 0.3 1.5 0.4 148 11 138 255 4.7 0.1 5 4.5 08/27/2005 05:30:00 1.8 0.6 3 0.7 1.6 0.7 3 0.4 1.1 0.7 2.6 0.4 233 15 247 255 4.6 0 4.8 4.5 08/27/2005 05:40:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.5 2.1 0.5 3.4 0.7 235 8 239 255 4.9 0 5 4.8 08/27/2005 05:50:00 2.6 0.6 3.8 1.1 2.4 0.7 3.8 1.1 1.3 0.5 3 0.4 210 15 246 255 5 0 5 4.8 08/27/2005 06:00:00 2.1 0.3 3 1.1 2 0.3 2.6 1.1 1 0.5 2.3 0.4 198 9 208 255 5.1 0 5.5 5 08/27/2005 06:10:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 147 24 179 255 4.7 0.1 5 4.5 08/27/2005 06:20:00 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.3 1.9 0.4 71 23 43 255 4.6 0.1 5.2 4.5 08/27/2005 06:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 120 20 142 255 4.6 0 5 4.5 08/27/2005 06:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 161 9 161 255 5.2 0.1 5.7 4.8 08/27/2005 06:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 136 12 168 255 5.6 0.2 6 5.2 08/27/2005 07:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 166 6 158 255 6.2 0.3 6.7 5.7 08/27/2005 07:10:00 0.9 0.5 3.4 0.4 1 0.6 3 0.4 0.7 0.4 1.9 0.4 235 28 282 255 7.4 0.3 7.8 6.7 08/27/2005 07:20:00 0.6 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 270 13 261 255 8.3 0.4 9 7.8 08/27/2005 07:30:00 1.1 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.8 0.5 2.3 0.4 248 15 246 255 9.3 0.2 9.6 9 08/27/2005 07:40:00 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 227 26 217 255 9.9 0.1 10.3 9.6 08/27/2005 07:50:00 1.6 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.3 0.7 3.4 0.4 240 19 256 255 10.2 0.1 10.3 9.8 08/27/2005 08:00:00 1.4 0.7 3 0.4 1.6 0.7 3 0.4 1.1 0.7 2.6 0.4 263 27 247 255 10.2 0.2 10.6 9.8 08/27/2005 08:10:00 1.2 0.8 3 0.4 1.3 0.8 3 0.4 1 0.7 3 0.4 283 23 298 255 10.5 0.2 10.9 10.3 08/27/2005 08:20:00 0.8 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 297 23 322 255 11.4 0.3 11.7 10.9 08/27/2005 08:30:00 2.2 1 4.2 0.4 2.2 1 4.2 0.4 2 1.1 4.9 0.4 290 27 297 255 11.5 0.3 12.2 11.1 08/27/2005 08:40:00 1.5 0.8 3 0.4 1.5 0.7 3.4 0.4 1.1 0.7 3 0.4 302 28 297 255 11.6 0.1 11.9 11.1 08/27/2005 08:50:00 1.7 0.8 3.4 0.4 1.8 0.7 3.4 0.4 1.5 0.8 3.4 0.4 306 15 305 255 11.5 0 11.9 11.4 08/27/2005 09:00:00 1.3 0.8 3 0.4 1.5 0.8 3 0.4 1.3 0.8 3 0.4 296 28 309 255 12.1 0 12.5 11.7 08/27/2005 09:10:00 2 0.6 3.8 0.4 2 0.6 3.8 0.4 1.7 0.7 3.8 0.4 311 15 297 255 12 0 12.7 11.9 08/27/2005 09:20:00 2 0.8 3.8 0.4 2.1 0.7 3.8 0.4 1.6 0.7 3.8 0.4 287 30 355 255 12.3 0.1 12.7 12.2 08/27/2005 09:30:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.5 2.7 0.6 4.2 0.4 302 15 303 255 12.5 0 12.7 12.2 08/27/2005 09:40:00 2.3 0.6 3.4 0.7 2.3 0.5 3.4 0.7 1.8 0.7 3.8 0.4 312 15 297 255 12.6 0.2 13.3 12.2 08/27/2005 09:50:00 2.3 1 4.2 0.4 2.3 0.9 4.2 0.4 1.8 1.1 4.2 0.4 308 18 294 255 13.2 0.1 13.8 13 08/27/2005 10:00:00 2.1 0.9 4.2 0.4 2.3 0.8 4.2 0.4 2 0.9 4.2 0.4 274 23 303 255 13 0.1 13.5 12.7 08/27/2005 10:10:00 1.8 0.9 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.7 3 0.4 300 30 311 255 13.9 0.4 14.9 13 08/27/2005 10:20:00 1.7 0.8 3.8 0.4 1.8 0.7 3.8 0.4 1.5 0.8 3.8 0.4 290 35 300 255 14.4 0.1 14.9 14.1 08/27/2005 10:30:00 2.1 0.8 3.8 0.4 2.2 0.7 3.8 0.4 2.2 0.6 4.2 0.7 304 15 320 255 14.4 0.2 15.2 13.8 08/27/2005 10:40:00 1.5 1 3.8 0.4 1.7 0.9 3.8 0.4 1.5 0.9 3.8 0.4 321 35 306 255 14.2 0.1 14.9 13.8 08/27/2005 10:50:00 1.7 1.1 4.6 0.4 1.9 1 4.6 0.4 1.5 1 4.9 0.4 291 28 292 255 14.8 0.2 15.2 14.4 08/27/2005 11:00:00 3 0.8 4.6 0.7 3.1 0.8 4.6 1.1 2.4 0.8 3.8 0.4 308 22 266 255 14.9 0 15.2 14.6 08/27/2005 11:10:00 2.1 1.1 4.2 0.4 2.2 1.1 4.6 0.4 1.9 1 4.6 0.4 280 47 256 255 15.2 0 15.5 15.2 08/27/2005 11:20:00 2.4 1 4.6 0.4 2.5 1 4.9 0.4 1.8 1 4.2 0.4 292 36 289 255 15.2 0.1 15.7 14.9 08/27/2005 11:30:00 2.5 1.1 4.6 0.4 2.6 1 4.9 0.7 2.3 0.9 4.2 0.4 293 20 300 255 15.3 0 15.7 15.2 08/27/2005 11:40:00 2.5 0.9 4.6 0.4 2.5 0.9 4.6 0.7 2 0.9 4.2 0.4 306 28 323 255 15.6 0 15.7 15.5 08/27/2005 11:50:00 3.6 1 5.7 1.1 3.5 1 5.7 1.1 2.9 1.2 6.1 0.4 301 16 317 255 15.7 0 16 15.7 08/27/2005 12:00:00 2.5 1.1 4.9 0.4 2.5 1.1 5.3 0.4 1.8 1.2 5.3 0.4 292 38 291 255 16.1 0.2 16.8 15.7 08/27/2005 12:10:00 2.4 1 4.6 0.4 2.4 1 4.6 0.4 2 1 4.6 0.4 295 32 293 255 16.4 0 17.1 16.3 08/27/2005 12:20:00 2.5 1 4.9 0.4 2.5 1 4.9 0.4 1.9 1 4.6 0.4 304 28 272 255 17 0.2 17.7 16.8 08/27/2005 12:30:00 2.6 1.1 4.9 0.4 2.5 1 4.9 0.4 1.9 1 4.9 0.4 296 30 313 255 17.7 0.2 18.5 17.1 08/27/2005 12:40:00 3.3 1 5.3 0.7 3.2 0.9 4.9 0.7 2.8 1 4.9 0.4 309 21 302 255 17.8 0 18.5 17.4 08/27/2005 12:50:00 2.8 1 4.9 0.4 2.6 1 4.9 0.4 1.9 0.9 4.2 0.4 298 33 307 255 18 0 18.5 17.7 08/27/2005 13:00:00 2.7 1.2 5.7 0.4 2.6 1.2 5.7 0.4 2.3 1.2 5.3 0.4 314 28 297 255 17.9 0 18.2 17.7 08/27/2005 13:10:00 2.9 0.8 4.6 1.1 2.8 0.8 4.6 0.7 2.5 0.9 4.6 0.4 304 19 297 255 18.2 0 18.5 18 08/27/2005 13:20:00 3 1.3 5.7 0.4 2.9 1.3 5.7 0.4 2.3 1.1 5.3 0.4 305 38 319 255 18.8 0.2 19.1 18.2 08/27/2005 13:30:00 4.1 0.9 6.5 1.5 4.2 0.9 6.5 1.9 3.6 0.9 6.5 1.1 292 15 290 255 18.7 0.3 19.1 18.2 08/27/2005 13:40:00 3.5 1.1 5.7 0.4 3.4 1 6.1 0.7 2.7 1.2 5.7 0.4 288 22 280 255 19.1 0.2 19.4 18.5 08/27/2005 13:50:00 3.2 1.2 6.1 0.4 3.1 1.2 5.7 0.4 2.5 1.2 5.3 0.4 287 28 294 255 19.4 0.1 19.7 19.1 08/27/2005 14:00:00 2.7 1.1 6.1 0.4 2.6 1.1 5.7 0.4 1.7 0.9 3.8 0.4 282 45 279 255 20 0.3 20.8 19.7 08/27/2005 14:10:00 3.1 1 6.5 0.7 3 1.1 6.5 0.7 2.6 1 5.3 0.4 275 22 269 255 20.5 0 21.1 20.5 08/27/2005 14:20:00 2.3 1.1 5.7 0.4 2.3 1.1 5.7 0.4 1.6 1.1 5.3 0.4 263 33 272 255 20.8 0 21.1 20.5 08/27/2005 14:30:00 2.8 1 5.3 0.4 2.8 1 5.7 0.4 2.3 1 4.9 0.4 246 24 254 255 20.7 0.2 21.1 20.5 08/27/2005 14:40:00 3.4 1.1 5.3 0.4 3.3 1.2 5.3 0.4 2.8 1 4.9 0.4 253 27 269 255 20.5 0 21.1 20.5 08/27/2005 14:50:00 2.8 1.2 5.7 0.4 2.9 1.1 5.3 0.4 2.2 1.2 5.3 0.4 257 35 271 255 21 0.1 21.7 20.5 08/27/2005 15:00:00 3.9 1.3 6.5 0.4 3.8 1.4 7.2 0.7 3.3 1.4 6.1 0.7 267 30 242 255 20.9 0.4 21.7 20.3 08/27/2005 15:10:00 3 1.1 6.1 0.4 3 1 5.7 0.4 2.3 1.1 4.9 0.4 224 24 221 255 20.4 0 20.8 20.3 08/27/2005 15:20:00 2.9 1 4.9 0.4 2.9 1 4.9 0.7 2.3 1 4.6 0.4 238 22 215 255 20.5 0 21.1 20.3 08/27/2005 15:30:00 3.4 0.9 5.3 1.5 3.5 0.8 5.3 1.5 2.8 1 5.7 0.4 237 21 241 255 20.5 0 20.8 20.5 08/27/2005 15:40:00 3.1 1.1 5.3 0.4 3.1 1 5.3 0.4 2.6 1.1 5.7 0.4 221 24 225 255 20.5 0 20.8 20.5 08/27/2005 15:50:00 2.4 0.8 4.6 0.7 2.4 0.9 4.6 0.4 2 0.8 3.8 0.4 211 24 198 255 21 0 21.1 20.5 08/27/2005 16:00:00 2.5 1 4.6 0.4 2.5 1 4.9 0.4 2 1 4.6 0.4 209 26 219 255 20.8 0.1 21.1 20.5 08/27/2005 16:10:00 1.6 0.9 3.8 0.4 1.7 0.9 3.8 0.4 1 0.7 3.4 0.4 213 26 209 255 20.3 0.2 20.8 19.7 08/27/2005 16:20:00 1.6 0.8 3 0.4 1.5 0.8 3 0.4 1.2 0.8 3.4 0.4 232 53 238 255 19.5 0.1 20 19.4 08/27/2005 16:30:00 1 0.6 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 246 28 234 255 19.2 0.1 19.7 18.8 08/27/2005 16:40:00 1.8 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.2 0.7 3 0.4 269 27 294 255 18.9 0.1 19.4 18.5 08/27/2005 16:50:00 2.4 0.8 4.6 0.7 2.3 1 4.6 0.4 1.7 0.8 3.8 0.4 283 22 255 255 18.5 0 19.1 18.2 08/27/2005 17:00:00 2.5 0.7 4.6 0.7 2.5 0.7 4.2 1.1 2 0.8 3.8 0.4 280 22 265 255 18.5 0.1 19.1 18.2 08/27/2005 17:10:00 2.3 0.9 4.6 0.4 2.4 0.8 4.6 0.7 1.7 0.9 4.2 0.4 278 29 267 255 18 0 18.2 18 08/27/2005 17:20:00 2.2 0.9 4.9 0.4 2.1 0.9 4.6 0.4 1.8 1 4.2 0.4 282 22 283 255 18 0 18.2 17.7 08/27/2005 17:30:00 2.3 0.8 4.6 0.4 2.2 0.8 4.2 0.4 1.5 0.8 3.8 0.4 266 22 313 255 17.7 0 17.7 17.4 08/27/2005 17:40:00 2.1 0.7 4.6 0.4 2.1 0.7 4.6 0.4 1.5 0.8 3.8 0.4 250 17 255 255 17.5 0 17.7 17.4 08/27/2005 17:50:00 2.5 0.6 3.8 0.7 2.4 0.7 3.8 0.4 2.1 0.6 3.4 0.4 271 16 253 255 17.6 0 18 17.1 08/27/2005 18:00:00 2.2 0.5 3.4 0.7 2 0.6 3.4 0.7 1.7 0.6 3 0.4 285 14 286 255 17.8 0.2 18.2 17.4 08/27/2005 18:10:00 2.3 0.5 3.4 1.5 2.2 0.5 3.8 1.1 1.6 0.6 3 0.4 299 12 287 255 17.1 0.3 17.7 16.6 08/27/2005 18:20:00 2.2 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.4 0.6 3 0.4 304 12 312 255 16 0.2 16.8 15.7 08/27/2005 18:30:00 1.7 0.5 3.4 0.4 1.6 0.5 3 0.4 1.1 0.6 2.6 0.4 309 15 286 255 15.5 0 16 15.2 08/27/2005 18:40:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 346 11 0 255 15 0 15.7 14.6 08/27/2005 18:50:00 1.8 0.5 3.4 0.7 1.5 0.6 3 0.4 0.7 0.5 2.6 0.4 329 19 297 255 14.5 0.2 15.5 14.1 08/27/2005 19:00:00 2.2 0.5 3.4 0.7 2.1 0.5 3 0.7 1.3 0.6 3 0.4 299 12 300 255 13.9 0 14.6 13.5 08/27/2005 19:10:00 2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 0.7 0.5 2.6 0.4 306 10 279 255 13.5 0.1 14.1 13.3 08/27/2005 19:20:00 2.1 0.5 3.4 1.1 1.8 0.7 3.8 0.4 1.1 0.5 2.3 0.4 317 19 290 255 13 0.2 13.8 12.7 08/27/2005 19:30:00 1.9 0.2 2.3 1.1 1.8 0.3 2.3 1.1 0.8 0.4 1.9 0.4 350 4 337 255 12.4 0 12.7 12.2 08/27/2005 19:40:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.4 0.5 0.2 1.5 0.4 15 8 30 255 12.1 0.1 12.7 11.7 08/27/2005 19:50:00 1.3 0.3 2.3 0.4 1.1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 22 8 22 255 11.7 0 12.2 11.7 08/27/2005 20:00:00 1.3 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 37 2 36 255 11.5 0.1 11.9 11.1 08/27/2005 20:10:00 1.3 0.4 2.3 0.4 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 49 8 61 255 11.1 0 11.7 11.1 08/27/2005 20:20:00 1.5 0.3 1.9 0.7 1.3 0.4 1.9 0.4 0.8 0.3 1.5 0.4 65 7 75 255 10.8 0.1 11.1 10.6 08/27/2005 20:30:00 1.6 0.5 2.6 0.4 1.4 0.6 3 0.4 0.8 0.3 1.9 0.4 66 8 51 255 10.4 0.1 10.9 10.3 08/27/2005 20:40:00 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.7 0.8 0.4 1.9 0.4 56 7 52 255 10 0 10.3 9.8 08/27/2005 20:50:00 1.7 0.4 2.6 0.7 1.5 0.5 2.3 0.4 0.6 0.4 1.9 0.4 66 9 59 255 9.8 0 9.8 9.6 08/27/2005 21:00:00 1.9 0.4 3 0.7 1.7 0.4 3 0.4 0.9 0.4 1.9 0.4 70 7 66 255 9.6 0 9.8 9.3 08/27/2005 21:10:00 2.1 0.3 2.6 1.1 2 0.3 2.6 1.1 0.7 0.4 1.9 0.4 87 7 73 255 9.3 0 9.6 9.3 08/27/2005 21:20:00 1.9 0.4 3.4 1.1 1.8 0.5 3.4 0.7 0.9 0.4 1.9 0.4 72 9 67 255 9.1 0 9.3 9 08/27/2005 21:30:00 2.1 0.4 3 0.7 1.9 0.4 3 0.7 0.8 0.4 1.9 0.4 62 9 58 255 8.9 0 9 8.8 08/27/2005 21:40:00 1.8 0.5 3 0.7 1.6 0.5 2.6 0.4 0.8 0.5 2.3 0.4 80 9 84 255 8.7 0 8.8 8.5 08/27/2005 21:50:00 1.7 0.3 2.6 0.7 1.4 0.4 2.6 0.4 0.4 0.2 1.5 0.4 96 8 104 255 8.5 0 8.8 8.5 08/27/2005 22:00:00 1.9 0.3 2.6 1.1 1.7 0.3 2.6 0.7 0.5 0.3 1.5 0.4 109 7 101 255 8.5 0 8.8 8.5 08/27/2005 22:10:00 2 0.4 3 1.1 1.8 0.4 3 0.7 0.9 0.5 1.9 0.4 115 11 95 255 8.4 0 8.5 8.5 08/27/2005 22:20:00 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 130 11 117 255 8.4 0 8.5 8.3 08/27/2005 22:30:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 0.7 0.4 1.9 0.4 122 7 137 255 8.4 0 8.5 8.3 08/27/2005 22:40:00 2.1 0.5 3.4 1.1 2 0.6 3.4 0.7 0.8 0.5 2.3 0.4 126 12 121 255 8.3 0 8.5 8.3 08/27/2005 22:50:00 1.8 0.6 3 0.4 1.7 0.6 3.4 0.4 0.6 0.4 2.3 0.4 127 13 156 255 8.2 0 8.5 8 08/27/2005 23:00:00 2.6 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.5 0.7 3 0.4 131 15 123 255 8 0 8.3 7.8 08/27/2005 23:10:00 3.4 0.6 4.9 1.9 3.4 0.6 4.6 1.9 2.7 0.5 4.2 1.5 129 10 121 255 8.5 0.3 9 7.8 08/27/2005 23:20:00 3.4 0.6 4.6 1.9 3.4 0.6 4.9 1.5 2.4 0.6 3.8 1.1 127 11 129 255 9.3 0.2 9.6 9 08/27/2005 23:30:00 4 0.6 5.7 2.3 4 0.6 5.3 2.3 2.9 0.6 4.2 1.5 127 10 119 255 9.5 0 9.6 9.3 08/27/2005 23:40:00 3.8 0.6 4.9 1.9 3.8 0.6 5.3 1.1 3 0.6 4.6 1.1 127 11 128 255 9.7 0 9.8 9.6 08/27/2005 23:50:00 3.6 0.5 4.6 2.3 3.6 0.5 4.9 2.3 2.8 0.6 4.6 1.1 134 10 127 255 9.6 0 9.8 9.6 08/28/2005 00:00:00 3.7 0.6 4.9 2.3 3.7 0.6 4.9 1.9 2.8 0.6 4.2 1.1 128 11 126 255 9.5 0 9.6 9.3 08/28/2005 00:10:00 3.6 0.6 4.9 2.3 3.5 0.6 4.6 1.9 2.3 0.6 4.2 0.7 125 11 117 255 9.5 0 9.6 9.3 08/28/2005 00:20:00 3.3 0.7 4.9 1.5 3.3 0.7 5.3 1.5 2.3 0.6 4.2 0.4 127 13 125 255 9.5 0 9.6 9.3 08/28/2005 00:30:00 2.7 0.6 4.6 1.5 2.6 0.7 4.9 1.1 1.7 0.7 4.2 0.4 120 13 126 255 9.4 0 9.6 9.3 08/28/2005 00:40:00 1.7 0.6 3.4 0.4 1.5 0.7 3 0.4 0.6 0.5 2.3 0.4 121 15 106 255 8.9 0.2 9.3 8.5 08/28/2005 00:50:00 1.7 0.6 3 0.4 1.6 0.7 3 0.4 0.7 0.5 2.3 0.4 113 15 115 255 8.7 0 8.8 8.5 08/28/2005 01:00:00 2.3 0.6 3.8 0.7 2.2 0.6 3.8 0.7 1.3 0.7 3 0.4 117 15 108 255 8.7 0 9 8.5 08/28/2005 01:10:00 2.3 0.7 3.8 0.4 2.2 0.7 3.8 0.4 1.1 0.7 2.6 0.4 113 16 104 255 9 0.1 9.3 8.8 08/28/2005 01:20:00 1.4 0.5 3 0.4 1.1 0.5 2.6 0.4 0.4 0.2 1.5 0.4 77 15 88 255 8.9 0 9 8.8 08/28/2005 01:30:00 1.5 0.3 2.6 0.7 1.3 0.3 2.3 0.7 0.4 0.1 1.5 0.4 66 15 74 255 8.5 0.1 8.8 8.5 08/28/2005 01:40:00 2.5 0.4 3.4 1.5 2.4 0.5 3.4 1.1 1.1 0.5 2.3 0.4 95 8 87 255 8.3 0 8.5 8.3 08/28/2005 01:50:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.5 1.3 0.5 2.6 0.4 97 8 93 255 8 0 8.3 7.8 08/28/2005 02:00:00 2.6 0.4 3.8 1.5 2.4 0.5 3.4 1.1 1.2 0.6 2.6 0.4 101 10 102 255 7.8 0 8 7.8 08/28/2005 02:10:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.6 0.5 2.6 0.4 101 7 103 255 7.9 0 8 7.8 08/28/2005 02:20:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.3 0.5 2.6 0.4 92 8 93 255 8.2 0 8.3 8 08/28/2005 02:30:00 2.6 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.3 0.7 2.6 0.4 94 11 95 255 8.1 0 8.3 8 08/28/2005 02:40:00 2.8 0.6 4.6 1.5 2.8 0.6 4.2 1.1 1.5 0.8 3.4 0.4 100 9 124 255 8 0 8.3 7.8 08/28/2005 02:50:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.5 2.1 0.5 3.4 0.7 106 9 102 255 8.2 0 8.5 8 08/28/2005 03:00:00 3.3 0.5 4.2 1.9 3.2 0.5 4.2 1.9 2.2 0.5 3.8 0.7 107 8 104 255 8.6 0 8.8 8.5 08/28/2005 03:10:00 3.2 0.4 4.2 1.9 3.1 0.4 3.8 1.5 2 0.6 3 0.4 104 7 100 255 8.9 0 9 8.8 08/28/2005 03:20:00 2.9 0.4 3.8 1.5 2.7 0.5 4.2 1.5 1.5 0.6 3 0.4 109 11 114 255 8.9 0 9 8.8 08/28/2005 03:30:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.3 0.6 2.6 0.4 116 12 110 255 8.8 0 9 8.8 08/28/2005 03:40:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.7 1.1 0.5 2.3 0.4 113 12 94 255 8.7 0 8.8 8.8 08/28/2005 03:50:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 0.7 1.4 0.5 2.6 0.4 107 12 105 255 8.7 0 9 8.8 08/28/2005 04:00:00 2.7 0.4 3.8 1.5 2.6 0.5 3.8 1.1 1.5 0.6 3 0.4 110 10 121 255 8.8 0 9 8.8 08/28/2005 04:10:00 2.9 0.5 4.2 1.5 2.7 0.5 3.8 1.1 1.8 0.5 3.4 0.4 102 10 104 255 8.9 0 9 9 08/28/2005 04:20:00 2.9 0.5 4.2 1.9 2.8 0.5 3.8 1.9 1.8 0.6 3 0.4 108 10 100 255 9 0 9 9 08/28/2005 04:30:00 2.9 0.6 3.8 1.1 2.7 0.6 3.8 0.7 1.8 0.6 3.4 0.4 107 11 106 255 8.9 0 9 9 08/28/2005 04:40:00 2.9 0.6 4.2 1.5 2.8 0.6 3.8 1.1 1.7 0.6 3.4 0.4 107 11 105 255 8.9 0 9 9 08/28/2005 04:50:00 2.7 0.6 4.2 0.7 2.6 0.6 4.2 0.4 1.7 0.7 3.4 0.4 110 13 117 255 8.9 0 9 9 08/28/2005 05:00:00 2.9 0.6 4.2 1.5 2.7 0.6 4.6 0.7 1.7 0.8 3.4 0.4 104 12 109 255 9 0 9 9 08/28/2005 05:10:00 3.1 0.5 4.2 1.9 3 0.5 4.2 1.5 2.1 0.6 3.8 0.7 94 10 94 255 9.1 0 9.3 9 08/28/2005 05:20:00 2.9 0.4 3.8 1.5 2.9 0.5 3.8 1.9 1.8 0.6 3.4 0.4 94 7 89 255 9.1 0 9.3 9 08/28/2005 05:30:00 2.9 0.5 4.6 1.5 2.9 0.5 4.2 1.9 1.7 0.6 3 0.4 94 10 91 255 9 0 9.3 9 08/28/2005 05:40:00 2.7 0.4 3.8 1.1 2.7 0.4 3.4 1.1 1.6 0.5 3.4 0.4 102 12 94 255 9.2 0 9.3 9 08/28/2005 05:50:00 2.6 0.5 3.8 1.1 2.5 0.6 3.8 1.1 1.5 0.7 3 0.4 108 12 96 255 9.3 0 9.6 9.3 08/28/2005 06:00:00 2.7 0.8 4.2 0.4 2.6 0.9 4.2 0.4 2.1 0.9 3.8 0.4 137 15 134 255 9.2 0 9.6 9 08/28/2005 06:10:00 3.1 0.6 4.6 1.1 3 0.7 4.6 1.1 1.9 0.6 3.4 0.4 129 13 121 255 9.3 0 9.3 9 08/28/2005 06:20:00 2.4 0.7 4.2 0.4 2.2 0.7 3.8 0.4 1.3 0.7 3 0.4 117 18 106 255 9.3 0 9.6 9.3 08/28/2005 06:30:00 2.5 0.6 4.2 0.7 2.5 0.7 4.6 0.7 1.6 0.6 3.4 0.4 120 12 127 255 9.1 0 9.3 9 08/28/2005 06:40:00 2.7 0.6 3.8 1.1 2.6 0.6 3.8 1.1 1.6 0.7 3 0.4 112 13 119 255 9.4 0 9.6 9.3 08/28/2005 06:50:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 0.7 0.5 2.3 0.4 115 13 124 255 9.5 0 9.6 9.6 08/28/2005 07:00:00 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 107 17 105 255 9.4 0 9.6 9.3 08/28/2005 07:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 138 255 9.4 0 9.6 9.3 08/28/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 138 255 9.5 0 9.6 9.3 08/28/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 255 255 9.8 0 10.1 9.6 08/28/2005 07:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 168 33 206 255 10.1 0 10.3 9.8 08/28/2005 07:50:00 1.1 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 167 23 144 255 10.2 0 10.3 10.1 08/28/2005 08:00:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 148 21 133 255 10.5 0 10.6 10.3 08/28/2005 08:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 132 26 117 255 10.9 0.1 11.1 10.6 08/28/2005 08:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 120 9 117 255 11.3 0 11.7 11.1 08/28/2005 08:30:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 94 20 100 255 11.6 0 11.7 11.4 08/28/2005 08:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 77 13 48 255 11.7 0 11.9 11.7 08/28/2005 08:50:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 84 14 89 255 11.7 0 11.9 11.7 08/28/2005 09:00:00 1.5 0.7 2.6 0.4 1.5 0.7 3 0.4 1.2 0.6 2.6 0.4 49 13 43 255 11.9 0 11.9 11.7 08/28/2005 09:10:00 2.1 0.5 3.4 0.7 2.2 0.5 3.4 1.1 1.6 0.6 3 0.4 41 12 47 255 11.9 0 11.9 11.9 08/28/2005 09:20:00 2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.5 0.6 3 0.4 75 22 86 255 11.9 0 11.9 11.7 08/28/2005 09:30:00 2.1 0.5 3.4 0.7 2 0.6 3.4 0.4 1.5 0.8 3 0.4 80 12 62 255 12 0 12.5 11.7 08/28/2005 09:40:00 1.9 0.6 3 0.4 1.7 0.6 3 0.4 1.6 0.6 3 0.4 78 22 73 255 12.2 0 12.2 11.9 08/28/2005 09:50:00 1.1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 82 15 100 255 12.1 0 12.2 11.9 08/28/2005 10:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 59 22 78 255 12.3 0 12.5 11.9 08/28/2005 10:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 15 6 27 255 12.6 0 12.7 12.5 08/28/2005 10:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 36 121 255 12.8 0 13.3 12.7 08/28/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 0 255 255 13.1 0.1 13.5 12.7 08/28/2005 10:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 156 45 206 255 13.5 0 14.1 13.3 08/28/2005 10:50:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 237 33 255 255 13.4 0 14.1 13 08/28/2005 11:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 263 76 261 255 13.5 0.1 13.8 13 08/28/2005 11:10:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 233 20 253 255 13.7 0 14.1 13.5 08/28/2005 11:20:00 1.2 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 307 49 338 255 13.9 0.1 14.6 13.5 08/28/2005 11:30:00 1.4 0.6 3 0.4 1.2 0.7 3 0.4 0.7 0.5 1.9 0.4 1 24 348 255 14.1 0 14.6 13.8 08/28/2005 11:40:00 1.1 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.6 0.4 2.3 0.4 3 20 33 255 14.1 0.1 14.6 13.8 08/28/2005 11:50:00 0.8 0.4 2.6 0.4 0.6 0.4 2.6 0.4 0.4 0.2 1.5 0.4 351 17 19 255 14.2 0.1 14.6 14.1 08/28/2005 12:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 355 24 327 255 14.4 0 14.9 14.4 08/28/2005 12:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 17 335 255 14.3 0 14.6 14.1 08/28/2005 12:20:00 0.7 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.5 0.4 267 29 241 255 14.2 0 14.6 14.1 08/28/2005 12:30:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 220 15 244 255 14.2 0 14.6 14.1 08/28/2005 12:40:00 1.3 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.8 0.6 2.6 0.4 206 17 202 255 14.2 0 14.6 14.1 08/28/2005 12:50:00 0.4 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 211 1 218 255 14 0.1 14.6 13.8 08/28/2005 13:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 235 10 211 255 14.1 0.1 14.6 13.8 08/28/2005 13:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 297 21 305 255 14.2 0.1 14.6 13.8 08/28/2005 13:20:00 0.7 0.4 1.9 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.9 0.4 286 23 275 255 14.2 0 14.6 14.1 08/28/2005 13:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 249 18 243 255 14.2 0 14.6 14.1 08/28/2005 13:40:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 281 8 268 255 14.2 0.1 14.6 14.1 08/28/2005 13:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 266 0 266 255 13.9 0 14.6 13.8 08/28/2005 14:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 295 7 295 255 13.8 0 14.4 13.5 08/28/2005 14:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 336 26 336 255 13.7 0 14.4 13.5 08/28/2005 14:20:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 359 2 1 255 13.8 0 14.4 13.5 08/28/2005 14:30:00 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 338 13 358 255 13.8 0 14.4 13.8 08/28/2005 14:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 317 17 329 255 13.8 0 14.4 13.5 08/28/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 13.8 0 14.4 13.5 08/28/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 13.9 0 14.4 13.8 08/28/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 13.9 0 14.4 13.8 08/28/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 13.8 0 14.4 13.5 08/28/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 13.8 0 14.4 13.5 08/28/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 13.7 0 14.1 13.5 08/28/2005 15:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 12 72 55 255 13.6 0.1 14.1 13.5 08/28/2005 16:00:00 1.6 0.4 2.3 0.7 1.5 0.4 2.3 0.4 1 0.5 2.3 0.4 55 9 49 255 13.5 0.1 13.8 13.3 08/28/2005 16:10:00 1.8 0.5 3 0.7 1.8 0.5 3 0.4 1.3 0.6 2.3 0.4 52 8 61 255 13.5 0 14.1 13.3 08/28/2005 16:20:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 63 22 38 255 13.5 0 14.1 13.3 08/28/2005 16:30:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 96 12 96 255 13.3 0 13.8 13.3 08/28/2005 16:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 87 9 99 255 13.1 0 13.3 13 08/28/2005 16:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 0 84 255 13 0.1 13.3 12.7 08/28/2005 17:00:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 87 7 87 255 12.8 0 13.3 12.7 08/28/2005 17:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 0 91 255 12.7 0 12.7 12.5 08/28/2005 17:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 0 91 255 12.5 0 12.5 12.5 08/28/2005 17:30:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 99 8 92 255 12.4 0 12.7 12.5 08/28/2005 17:40:00 0.8 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.5 0.4 1.9 0.4 112 7 126 255 12.4 0 12.5 12.2 08/28/2005 17:50:00 1.8 0.9 3 0.4 1.6 0.9 3 0.4 1.1 0.7 2.3 0.4 98 17 100 255 12.3 0 12.5 12.2 08/28/2005 18:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 182 30 195 255 12.1 0 12.2 11.9 08/28/2005 18:10:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 134 5 138 255 11.9 0 11.9 11.9 08/28/2005 18:20:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 149 19 133 255 11.9 0 11.9 11.7 08/28/2005 18:30:00 1 0.2 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 151 12 142 255 11.8 0 11.9 11.7 08/28/2005 18:40:00 1.4 0.3 2.3 0.7 1.2 0.4 2.3 0.4 0.5 0.3 1.5 0.4 126 12 115 255 11.7 0 11.9 11.7 08/28/2005 18:50:00 1.2 0.7 2.6 0.4 1 0.7 2.3 0.4 0.6 0.4 1.9 0.4 115 19 111 255 11.7 0 11.7 11.7 08/28/2005 19:00:00 1.2 0.3 2.3 0.4 0.9 0.4 2.3 0.4 0.5 0.3 1.9 0.4 117 9 102 255 11.7 0 11.7 11.7 08/28/2005 19:10:00 2.4 0.7 3.8 1.1 2.2 0.8 3.8 0.7 1.6 0.7 3 0.4 121 9 127 255 11.6 0 11.7 11.4 08/28/2005 19:20:00 2.3 0.4 3 1.5 2 0.4 3 1.1 1.5 0.4 2.6 0.4 111 11 106 255 11.6 0 11.7 11.7 08/28/2005 19:30:00 1 0.7 3 0.4 0.7 0.6 2.3 0.4 0.5 0.5 2.3 0.4 112 15 85 255 11.5 0 11.7 11.4 08/28/2005 19:40:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 303 51 322 255 11.3 0 11.7 11.4 08/28/2005 19:50:00 1.3 0.7 3.4 0.4 0.8 0.7 3.4 0.4 0.7 0.6 2.6 0.4 15 47 84 255 11.3 0 11.4 11.1 08/28/2005 20:00:00 1.8 0.7 3.4 0.4 1.4 0.8 3.4 0.4 1 0.8 3 0.4 73 27 69 255 11.3 0 11.4 11.1 08/28/2005 20:10:00 2.3 0.8 3.8 0.4 2 0.8 3.8 0.4 1.5 0.7 3.4 0.4 104 17 114 255 11.3 0 11.4 11.4 08/28/2005 20:20:00 1.9 0.5 3 0.7 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 142 20 133 255 11.3 0 11.4 11.1 08/28/2005 20:30:00 1.3 0.8 3 0.4 0.9 0.7 2.6 0.4 0.9 0.7 2.6 0.4 251 45 284 255 11.1 0 11.4 11.1 08/28/2005 20:40:00 0.7 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 44 107 125 255 11.1 0 11.1 11.1 08/28/2005 20:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 67 22 85 255 11.1 0 11.1 10.9 08/28/2005 21:00:00 1.1 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.4 0.2 1.5 0.4 84 10 96 255 10.9 0 11.1 10.9 08/28/2005 21:10:00 2.8 0.5 3.8 1.9 2.5 0.5 3.8 1.5 1.9 0.5 3 0.4 84 7 73 255 10.9 0 11.1 10.9 08/28/2005 21:20:00 2.4 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.4 0.7 3 0.4 83 19 70 255 10.9 0 11.1 10.9 08/28/2005 21:30:00 3.3 0.6 5.3 1.5 3.1 0.7 5.3 1.1 2.3 0.7 4.2 0.4 88 12 85 255 10.9 0 11.1 10.9 08/28/2005 21:40:00 3.9 0.6 5.3 2.3 3.7 0.6 5.3 1.9 2.8 0.7 4.6 0.4 102 11 93 255 10.8 0 11.1 10.9 08/28/2005 21:50:00 3.1 0.8 4.9 1.1 2.9 0.9 4.9 0.7 2.2 0.8 4.6 0.4 101 20 119 255 10.8 0 10.9 10.9 08/28/2005 22:00:00 3.1 0.9 5.3 1.5 2.9 0.9 5.7 1.1 2 0.9 4.2 0.4 94 19 79 255 10.9 0 10.9 10.9 08/28/2005 22:10:00 3.5 0.7 4.9 1.1 3.3 0.7 4.9 1.1 2.6 0.8 4.9 0.4 95 13 99 255 10.9 0 11.1 10.9 08/28/2005 22:20:00 3.6 1.1 6.5 1.5 3.5 1.1 6.5 1.1 2.6 1 6.1 0.4 85 17 106 255 10.9 0 11.1 10.9 08/28/2005 22:30:00 5 0.9 7.6 2.6 4.9 1 8 2.6 3.9 0.9 6.5 1.9 84 12 89 255 11.1 0 11.1 10.9 08/28/2005 22:40:00 4.8 1.5 8 1.5 4.7 1.5 8 0.7 3.9 1.4 7.2 0.4 67 15 56 255 11.2 0 11.4 11.1 08/28/2005 22:50:00 6.5 1.6 11.5 3.8 6.4 1.6 11.1 3.8 5.1 1.3 9.1 2.3 71 13 61 255 11.3 0 11.4 11.1 08/28/2005 23:00:00 3.9 1.2 6.5 0.7 3.9 1.1 6.8 1.5 3.2 1.1 6.1 0.4 84 21 70 255 11.3 0 11.4 11.1 08/28/2005 23:10:00 3.5 0.7 5.7 1.9 3.5 0.7 5.7 1.9 2.9 0.7 4.6 1.1 91 12 105 255 11.1 0 11.4 11.1 08/28/2005 23:20:00 5.3 1.4 9.5 0.7 5.3 1.3 9.5 1.9 4.4 1.3 9.5 1.5 71 16 52 255 11.2 0 11.4 11.1 08/28/2005 23:30:00 6.1 1.3 9.9 3 6.1 1.3 9.9 3.4 5 1.4 8.8 1.9 65 13 71 255 11.5 0 11.7 11.4 08/28/2005 23:40:00 6 1.2 9.5 3 5.9 1.2 9.1 3 4.9 1.3 8 1.9 70 17 60 255 11.7 0 11.7 11.7 08/28/2005 23:50:00 4.5 1.4 9.5 1.5 4.6 1.4 9.9 1.5 3.5 1.2 8 0.7 79 19 67 255 11.7 0 11.7 11.7 08/29/2005 00:00:00 3.2 1.2 6.5 0.4 3.4 1.1 6.8 0.4 2.7 1 4.9 0.7 80 20 72 255 11.7 0 11.7 11.7 08/29/2005 00:10:00 5.1 1.3 8 1.5 5.2 1.3 8 2.3 4.3 1.1 7.2 1.1 58 20 52 255 11.6 0 11.7 11.4 08/29/2005 00:20:00 5.5 1.8 10.7 1.9 5.6 1.7 10.3 2.3 4.6 1.6 9.1 1.5 51 21 29 255 11.7 0 11.7 11.7 08/29/2005 00:30:00 6.7 1.5 9.9 3.4 6.8 1.5 10.3 3.8 5.6 1.6 10.3 1.9 59 15 76 255 12.1 0 12.2 11.7 08/29/2005 00:40:00 6 1.6 10.7 1.9 6 1.5 10.7 3 4.9 1.5 9.9 1.5 55 18 40 255 12.2 0 12.2 11.9 08/29/2005 00:50:00 4.1 1.4 8.4 0.7 4.1 1.4 8.4 1.5 3.2 1.3 7.6 0.4 55 24 64 255 12 0 12.2 11.7 08/29/2005 01:00:00 4.6 1.3 9.1 1.1 4.6 1.3 8.8 1.5 3.5 1.1 7.2 1.5 30 17 32 255 11.7 0 11.9 11.7 08/29/2005 01:10:00 5.6 1.3 9.5 2.3 5.7 1.3 9.9 2.3 4.5 1.1 8 1.9 56 18 26 255 11.5 0 11.7 11.4 08/29/2005 01:20:00 6.5 1.6 10.3 2.3 6.5 1.7 10.3 1.5 5.5 1.6 9.1 2.3 50 17 42 255 11.6 0 11.7 11.4 08/29/2005 01:30:00 7.8 1.8 12.2 2.6 7.7 1.8 12.2 3 6.4 1.6 11.1 3 44 16 51 255 11.9 0.1 12.2 11.7 08/29/2005 01:40:00 4.9 1.3 8.4 1.9 4.9 1.3 8.4 2.3 4.2 1.3 8 1.1 77 22 65 255 11.9 0.1 12.2 11.7 08/29/2005 01:50:00 5.9 1.9 11.8 1.1 5.9 1.8 11.1 2.3 4.6 1.8 9.5 0.4 64 24 81 255 11.5 0 11.7 11.4 08/29/2005 02:00:00 5.2 2.3 13 0.7 5.3 2.2 13.3 1.1 4.3 1.9 11.1 0.7 61 21 39 255 11.7 0 11.9 11.7 08/29/2005 02:10:00 5 1 7.2 1.9 5 0.9 7.6 2.6 4.2 1 6.8 2.3 63 17 62 255 11.8 0 11.9 11.7 08/29/2005 02:20:00 3.4 1.3 8.8 0.4 3.2 1.4 8.8 0.4 2.7 1.1 6.1 0.7 88 33 21 255 11.6 0 11.7 11.4 08/29/2005 02:30:00 3.6 1 6.5 1.5 3.5 1 6.5 1.1 2.9 0.9 5.7 1.1 74 21 67 255 11.1 0 11.4 11.1 08/29/2005 02:40:00 2.7 1 5.7 0.4 2.6 1 5.7 0.4 2.1 0.8 5.3 0.7 63 22 74 255 10.9 0.1 11.1 10.6 08/29/2005 02:50:00 4.3 0.8 6.5 2.3 4.2 0.8 6.5 1.9 3.4 0.8 5.7 1.5 64 17 64 255 10.6 0 10.9 10.6 08/29/2005 03:00:00 4.3 0.9 6.8 1.9 4.2 1 6.8 1.5 3.3 0.9 6.1 0.7 77 15 71 255 10.5 0 10.6 10.6 08/29/2005 03:10:00 4.2 1.5 8.4 0.4 4.2 1.5 8.4 0.4 3.4 1.2 7.6 1.1 68 20 79 255 10.5 0 10.6 10.3 08/29/2005 03:20:00 3.8 1 6.5 1.5 3.8 1 6.5 1.1 3.3 0.9 6.5 1.1 64 16 63 255 10.6 0 10.9 10.6 08/29/2005 03:30:00 1.8 0.7 4.2 0.4 1.6 0.8 3.4 0.4 1.3 0.6 3 0.4 105 28 89 255 10.5 0 10.9 10.3 08/29/2005 03:40:00 3 0.8 4.6 0.7 2.7 1 4.6 0.4 2.1 1 4.2 0.4 85 22 61 255 10.2 0 10.6 10.1 08/29/2005 03:50:00 4.1 1.1 8 1.9 4.1 1.1 8 1.9 3.2 1.2 7.2 0.7 66 18 28 255 10.2 0 10.6 10.1 08/29/2005 04:00:00 3.6 0.9 6.1 1.5 3.5 0.9 5.7 1.5 2.4 0.9 4.9 0.4 83 17 84 255 10.3 0 10.3 10.3 08/29/2005 04:10:00 2 0.6 3.8 0.7 1.8 0.7 3.8 0.4 1.2 0.6 3 0.4 93 23 110 255 10.2 0 10.3 10.1 08/29/2005 04:20:00 3.3 1.2 6.5 0.4 3.2 1.3 6.1 0.4 2.5 1.1 5.3 0.4 90 26 39 255 10.2 0 10.3 10.1 08/29/2005 04:30:00 3.6 0.9 5.7 1.1 3.5 0.9 5.7 0.7 2.7 1 5.7 0.4 78 21 35 255 10.4 0 10.6 10.3 08/29/2005 04:40:00 3.4 0.8 5.7 1.5 3.3 0.8 5.7 1.5 2.7 0.8 5.3 0.7 77 15 74 255 10.5 0 10.6 10.3 08/29/2005 04:50:00 3.6 0.7 5.3 0.7 3.6 0.7 4.9 0.7 2.9 0.7 4.6 0.7 83 11 52 255 10.4 0 10.6 10.3 08/29/2005 05:00:00 3.6 0.7 5.7 1.5 3.5 0.7 5.7 1.5 2.7 0.8 4.9 0.7 84 12 88 255 10.5 0 10.6 10.6 08/29/2005 05:10:00 3.4 0.6 4.9 1.5 3.3 0.7 4.9 1.5 2.3 0.7 4.6 0.7 87 12 96 255 10.5 0 10.6 10.3 08/29/2005 05:20:00 2.3 0.8 4.2 0.4 2.3 0.8 4.6 0.4 1.5 0.7 3.4 0.4 103 15 131 255 10.5 0 10.6 10.3 08/29/2005 05:30:00 2.8 0.6 4.6 1.1 2.5 0.7 4.2 0.7 1.9 0.7 3.4 0.4 113 14 113 255 10.4 0 10.6 10.3 08/29/2005 05:40:00 3.2 0.6 4.6 1.1 3 0.7 4.6 0.4 2.4 0.5 3.4 0.7 126 13 126 255 10.6 0 10.6 10.6 08/29/2005 05:50:00 2.6 0.9 4.6 0.4 2.5 0.8 4.2 0.4 2 0.8 3.4 0.4 141 14 142 255 10.5 0 10.6 10.6 08/29/2005 06:00:00 3 0.6 4.6 1.1 3 0.6 4.6 1.1 2.6 0.6 4.2 0.7 143 13 138 255 10.5 0 10.6 10.3 08/29/2005 06:10:00 3 0.9 4.6 0.7 3 0.9 4.6 1.1 2.2 0.8 4.2 0.4 122 17 131 255 10.6 0 10.6 10.6 08/29/2005 06:20:00 2.7 0.9 4.6 0.4 2.8 0.8 4.6 0.7 1.9 0.8 3.8 0.4 101 15 111 255 10.6 0 10.9 10.6 08/29/2005 06:30:00 1.4 0.5 2.6 0.4 1.5 0.5 3 0.4 1.4 0.5 3 0.4 116 12 110 255 10.5 0 10.9 10.6 08/29/2005 06:40:00 2.1 0.7 3.4 0.4 2.1 0.7 3.4 0.4 1.8 0.6 3 0.4 111 13 97 255 10.3 0 10.6 10.3 08/29/2005 06:50:00 1.7 0.7 3 0.4 1.7 0.8 3 0.4 1.3 0.7 3 0.4 105 26 109 255 10.5 0 10.6 10.3 08/29/2005 07:00:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.4 0.6 3 0.4 82 17 99 255 10.6 0 10.6 10.6 08/29/2005 07:10:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.4 0.2 1.5 0.4 64 15 93 255 10.5 0 10.6 10.3 08/29/2005 07:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 40 16 18 255 10.3 0 10.6 10.3 08/29/2005 07:30:00 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 16 5 19 255 10.3 0 10.6 10.3 08/29/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 255 255 10.3 0 10.6 10.3 08/29/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 26 255 255 10.2 0 10.3 10.3 08/29/2005 08:00:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 91 15 106 255 10.3 0 10.3 10.3 08/29/2005 08:10:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.5 0.7 3 0.4 108 11 101 255 10.3 0 10.6 10.3 08/29/2005 08:20:00 1.5 1 3.8 0.4 1.4 1 3.4 0.4 1 0.7 3 0.4 102 17 114 255 10.4 0 10.6 10.3 08/29/2005 08:30:00 0.7 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 85 10 67 255 10.6 0 10.9 10.6 08/29/2005 08:40:00 1.6 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 111 16 115 255 10.9 0 10.9 10.9 08/29/2005 08:50:00 1.2 0.5 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.4 1.9 0.4 124 11 131 255 10.9 0 11.1 10.9 08/29/2005 09:00:00 2 0.4 3 0.7 1.9 0.4 2.6 0.7 1.4 0.5 2.6 0.4 110 10 112 255 11.1 0 11.4 11.1 08/29/2005 09:10:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.3 0.5 2.6 0.4 112 15 92 255 11.3 0 11.4 11.1 08/29/2005 09:20:00 2 0.5 3 0.7 1.8 0.5 2.6 0.4 1.3 0.5 2.3 0.4 105 8 102 255 11.5 0 11.7 11.4 08/29/2005 09:30:00 2.2 0.5 3.4 0.7 1.9 0.5 3 0.4 1.5 0.6 2.6 0.4 99 9 102 255 11.5 0 11.7 11.4 08/29/2005 09:40:00 2.1 0.5 3.4 1.1 1.7 0.6 3 0.4 1.2 0.5 2.6 0.4 84 11 87 255 11.6 0 11.7 11.4 08/29/2005 09:50:00 2.4 0.7 3.8 0.4 2.1 0.8 3.8 0.4 1.4 0.7 3 0.4 68 20 81 255 11.7 0 11.7 11.7 08/29/2005 10:00:00 2.6 0.6 3.8 1.1 2.3 0.7 3.8 0.7 1.9 0.7 3.4 0.4 60 11 68 255 11.7 0 11.9 11.7 08/29/2005 10:10:00 2.2 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.3 0.7 3 0.4 48 17 62 255 11.7 0 11.7 11.7 08/29/2005 10:20:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.6 0.5 2.6 0.4 38 12 28 255 11.7 0 11.9 11.7 08/29/2005 10:30:00 1.9 0.5 3 0.7 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 46 16 42 255 11.9 0 12.2 11.7 08/29/2005 10:40:00 2 0.5 3.4 0.7 1.7 0.6 3 0.4 1.3 0.6 3 0.4 46 14 49 255 12.1 0 12.2 11.9 08/29/2005 10:50:00 2 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.3 0.7 3 0.4 46 12 55 255 12 0 12.2 11.9 08/29/2005 11:00:00 1.7 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1.1 0.6 2.6 0.4 43 15 40 255 12.1 0 12.2 11.9 08/29/2005 11:10:00 1.5 0.6 2.6 0.4 1.3 0.7 2.6 0.4 1 0.6 2.6 0.4 25 17 43 255 12.3 0 12.5 12.2 08/29/2005 11:20:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 35 19 33 255 12.5 0 12.7 12.5 08/29/2005 11:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 61 22 74 255 12.8 0 12.7 12.5 08/29/2005 11:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 81 22 106 255 12.8 0 12.7 12.7 08/29/2005 11:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 96 15 52 255 13 0 13.3 12.7 08/29/2005 12:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 98 24 74 255 13.7 0 14.4 13.3 08/29/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 143 61 255 255 13.9 0.1 14.6 13.8 08/29/2005 12:20:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 226 19 226 255 14.7 0.2 15.5 14.4 08/29/2005 12:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 253 39 216 255 15 0 15.7 14.9 08/29/2005 12:40:00 0.8 0.5 1.9 0.4 0.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 249 28 237 255 14.6 0 15.2 14.4 08/29/2005 12:50:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 213 22 198 255 14.6 0.2 15.2 14.4 08/29/2005 13:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 232 45 198 255 15 0.1 15.5 14.6 08/29/2005 13:10:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 215 21 218 255 15.1 0 15.5 15.2 08/29/2005 13:20:00 0.9 0.7 3 0.4 0.8 0.6 3 0.4 0.7 0.5 2.3 0.4 240 24 274 255 15 0 15.5 14.9 08/29/2005 13:30:00 0.9 0.6 3 0.4 0.8 0.6 3 0.4 0.7 0.5 3 0.4 230 21 243 255 15.2 0.1 15.7 14.9 08/29/2005 13:40:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 214 64 179 255 15.6 0 16 15.5 08/29/2005 13:50:00 1.3 0.8 3 0.4 1.1 0.8 3 0.4 1 0.7 3 0.4 236 36 263 255 15.9 0 16.8 15.7 08/29/2005 14:00:00 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 241 64 201 255 15.9 0 16.6 15.7 08/29/2005 14:10:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 309 29 317 255 16.4 0.4 17.1 15.7 08/29/2005 14:20:00 1.5 0.7 3.4 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 272 28 253 255 16.8 0.1 17.1 16.6 08/29/2005 14:30:00 1.1 0.9 3.4 0.4 0.9 0.8 3.4 0.4 0.8 0.8 3 0.4 271 51 252 255 16.7 0 16.8 16.6 08/29/2005 14:40:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 258 53 255 255 16.8 0 17.1 16.6 08/29/2005 14:50:00 1.8 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.3 0.9 3.4 0.4 271 22 280 255 17.2 0 17.4 17.1 08/29/2005 15:00:00 2 0.8 3.8 0.4 1.7 0.9 3.8 0.4 1.4 0.8 3.4 0.4 290 35 333 255 17.5 0.3 18.5 16.8 08/29/2005 15:10:00 1.9 0.9 3.8 0.4 1.6 1 4.2 0.4 1.5 1 3.8 0.4 308 38 268 255 17.5 0.2 18 16.8 08/29/2005 15:20:00 2.3 0.8 4.2 0.4 2 0.9 3.8 0.4 1.7 0.8 3.8 0.4 287 27 280 255 16.6 0.2 17.1 16.3 08/29/2005 15:30:00 2.7 0.8 4.6 0.4 2.5 0.8 4.6 0.4 2.2 0.7 3.8 0.7 290 18 305 255 16.4 0.1 16.8 16 08/29/2005 15:40:00 2.6 0.8 4.2 0.4 2.4 0.9 4.2 0.4 2.1 0.8 3.8 0.4 253 39 290 255 17 0.1 17.1 16.6 08/29/2005 15:50:00 2.4 0.9 4.9 0.4 2.2 0.9 4.6 0.4 1.6 0.8 3.8 0.4 221 32 270 255 16.5 0 16.8 16.3 08/29/2005 16:00:00 2.7 1.1 5.3 0.4 2.5 1.1 4.9 0.4 1.9 1 4.9 0.4 263 41 286 255 16.8 0 17.1 16.6 08/29/2005 16:10:00 2.9 0.9 4.9 0.7 2.6 1 4.9 0.4 2 1 4.6 0.4 302 21 296 255 16.4 0.1 16.8 16 08/29/2005 16:20:00 2.8 0.8 4.9 1.1 2.6 0.9 4.6 0.7 1.7 1 4.6 0.4 300 27 284 255 15.9 0.1 16.3 15.7 08/29/2005 16:30:00 2.3 0.7 3.8 0.4 2.1 0.8 3.8 0.4 1.8 0.9 3.8 0.4 301 13 280 255 15.7 0 16.3 15.7 08/29/2005 16:40:00 2.8 0.6 4.2 1.1 2.7 0.7 4.2 1.1 2.1 0.8 3.8 0.4 297 15 314 255 15.7 0 16.3 15.5 08/29/2005 16:50:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.2 0.6 2.6 0.4 299 24 283 255 15.6 0 16.3 15.5 08/29/2005 17:00:00 2.3 0.8 4.6 1.1 2.1 0.9 4.6 0.7 1.3 0.9 3.8 0.4 276 27 259 255 15.6 0 16.3 15.5 08/29/2005 17:10:00 3 0.9 5.3 1.1 2.8 1 5.3 0.7 2.2 1 4.6 0.4 280 17 278 255 15.5 0 16 15.2 08/29/2005 17:20:00 2.3 1 4.9 0.4 2.1 1 4.6 0.4 1.4 0.9 3.8 0.4 272 19 292 255 15.3 0 15.7 15.2 08/29/2005 17:30:00 2.6 0.8 4.6 0.7 2.3 0.9 4.9 0.4 1.3 0.7 3.4 0.4 267 18 259 255 15.1 0.1 15.7 14.9 08/29/2005 17:40:00 2.2 0.7 4.2 0.4 1.9 0.8 3.8 0.4 1.1 0.8 3 0.4 265 20 255 255 14.9 0 15.5 14.6 08/29/2005 17:50:00 1.9 0.7 3.8 0.4 1.7 0.7 3.4 0.4 0.9 0.6 3 0.4 270 23 259 255 14.7 0.1 15.2 14.6 08/29/2005 18:00:00 1.7 0.7 3 0.4 1.4 0.8 3.4 0.4 0.8 0.6 3.4 0.4 268 15 255 255 14.4 0.1 15.2 14.4 08/29/2005 18:10:00 1.6 0.6 3.4 0.4 1.4 0.7 3 0.4 0.8 0.5 3 0.4 262 16 235 255 14 0.1 14.6 13.8 08/29/2005 18:20:00 1.2 0.7 2.6 0.4 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 258 14 261 255 13.9 0 14.4 13.8 08/29/2005 18:30:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.7 0.5 2.3 0.4 272 13 264 255 13.8 0 14.4 13.5 08/29/2005 18:40:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 275 14 276 255 13.7 0.1 14.4 13.5 08/29/2005 18:50:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 282 10 280 255 13.5 0.1 14.1 13.3 08/29/2005 19:00:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 268 22 273 255 13.1 0.2 13.5 12.7 08/29/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 255 255 12.7 0 13.3 12.5 08/29/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 255 255 12.5 0.1 13 12.2 08/29/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 255 255 12.1 0.2 12.7 11.9 08/29/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 255 255 11.7 0 11.9 11.7 08/29/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 255 255 11.4 0 11.7 11.1 08/29/2005 20:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 266 24 305 255 11.1 0 11.4 10.9 08/29/2005 20:10:00 1.9 0.3 2.3 1.1 1.7 0.3 2.3 0.7 0.4 0.1 1.1 0.4 305 0 305 255 10.7 0 11.1 10.6 08/29/2005 20:20:00 1.4 0.2 1.9 1.1 1.2 0.2 1.9 0.7 0.4 0 0.4 0.4 305 0 305 255 10.5 0 10.6 10.3 08/29/2005 20:30:00 1.2 0.2 1.9 0.7 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 305 0 305 255 10.2 0 10.6 10.1 08/29/2005 20:40:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 307 0 307 255 10.1 0 10.3 9.8 08/29/2005 20:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 0 307 255 9.8 0 10.1 9.6 08/29/2005 21:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 307 0 307 255 9.6 0 9.6 9.6 08/29/2005 21:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 0 307 255 9.5 0 9.6 9.3 08/29/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 0 255 255 9.4 0 9.6 9.3 08/29/2005 21:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 0 307 255 9.1 0 9.3 9 08/29/2005 21:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 230 82 136 255 9.1 0 9.3 9 08/29/2005 21:50:00 1 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.8 0.4 1.5 0.4 136 0 136 255 9.1 0 9 9 08/29/2005 22:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 136 0 137 255 9 0 9 9 08/29/2005 22:10:00 1.4 0.3 1.9 0.4 0.9 0.4 1.5 0.4 0.6 0.4 1.5 0.4 118 8 113 255 8.9 0 9 9 08/29/2005 22:20:00 1.5 0.3 1.9 0.7 1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 114 4 116 255 8.9 0 9 8.8 08/29/2005 22:30:00 1.2 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 96 5 104 255 8.8 0 9 8.8 08/29/2005 22:40:00 1.3 0.2 1.9 0.7 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 93 1 93 255 8.6 0 8.8 8.5 08/29/2005 22:50:00 1.5 0.3 1.9 0.7 0.9 0.3 1.9 0.4 0.4 0 0.4 0.4 58 9 63 255 8.6 0 8.8 8.5 08/29/2005 23:00:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 0.4 0 0.7 0.4 43 1 41 255 8.5 0 8.8 8.5 08/29/2005 23:10:00 1.5 0.2 2.3 0.7 1 0.3 1.9 0.4 0.4 0 0.4 0.4 44 0 43 255 8.5 0 8.5 8.5 08/29/2005 23:20:00 1.5 0.2 1.9 1.1 1 0.3 1.9 0.4 0.4 0 0.7 0.4 43 0 44 255 8.4 0 8.5 8.5 08/29/2005 23:30:00 1.2 0.2 1.9 0.7 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 43 0 44 255 8.4 0 8.5 8.5 08/29/2005 23:40:00 0.8 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 0 44 255 8.4 0 8.5 8.5 08/29/2005 23:50:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 16 43 255 8.7 0 8.8 8.5 08/30/2005 00:00:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 110 17 87 255 8.8 0 8.8 8.8 08/30/2005 00:10:00 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 131 4 133 255 8.7 0 8.8 8.8 08/30/2005 00:20:00 1.1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 119 10 133 255 8.8 0 9 8.8 08/30/2005 00:30:00 1.4 0.3 1.9 0.7 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 111 2 112 255 8.9 0 9 8.8 08/30/2005 00:40:00 1.5 0.3 2.3 0.4 1.1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 104 2 99 255 8.9 0 9 8.8 08/30/2005 00:50:00 1.4 0.3 2.3 0.4 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 104 6 84 255 8.9 0 9 8.8 08/30/2005 01:00:00 1.4 0.2 1.9 0.7 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 115 7 105 255 9 0 9 9 08/30/2005 01:10:00 1.2 0.2 1.9 0.7 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 119 0 119 255 9 0 9 9 08/30/2005 01:20:00 1.3 0.3 2.3 0.7 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 119 0 119 255 9 0 9 9 08/30/2005 01:30:00 1.4 0.2 1.9 0.7 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 119 0 119 255 8.9 0 9 9 08/30/2005 01:40:00 1.4 0.2 1.9 0.7 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 118 1 119 255 8.9 0 9 9 08/30/2005 01:50:00 1.5 0.3 2.3 0.7 0.9 0.4 1.5 0.4 0.6 0.3 1.1 0.4 120 15 115 255 9 0 9.3 9 08/30/2005 02:00:00 1.6 0.2 2.3 0.7 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 152 9 147 255 9.1 0 9.3 9 08/30/2005 02:10:00 1.1 0.3 2.3 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 160 17 189 255 9.2 0 9.3 9 08/30/2005 02:20:00 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 188 9 188 255 9.3 0 9.3 9.3 08/30/2005 02:30:00 1.6 0.3 2.3 0.4 1.1 0.4 2.3 0.4 0.7 0.4 1.5 0.4 198 6 196 255 9.4 0 9.6 9.3 08/30/2005 02:40:00 1.3 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.5 0.4 202 1 204 255 9.5 0 9.6 9.3 08/30/2005 02:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 53 90 255 9.5 0 9.6 9.3 08/30/2005 03:00:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 128 36 160 255 9.5 0 9.6 9.6 08/30/2005 03:10:00 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 236 107 171 255 9.5 0 9.6 9.6 08/30/2005 03:20:00 1.5 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 2 18 4 255 9.5 0 9.6 9.6 08/30/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 9.5 0 9.6 9.6 08/30/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 9.6 0 9.6 9.6 08/30/2005 03:50:00 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 3 23 353 255 9.6 0 9.6 9.6 08/30/2005 04:00:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 58 0 58 255 9.6 0 9.6 9.6 08/30/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 255 255 9.5 0 9.6 9.6 08/30/2005 04:20:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 58 255 9.5 0 9.6 9.3 08/30/2005 04:30:00 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 58 255 9.4 0 9.6 9.3 08/30/2005 04:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 58 0 58 255 9.2 0 9.6 9 08/30/2005 04:50:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 13 58 255 9 0 9 8.8 08/30/2005 05:00:00 1.3 0.2 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 103 5 101 255 8.7 0 9 8.8 08/30/2005 05:10:00 1.4 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 124 2 125 255 8.5 0.1 8.8 8.5 08/30/2005 05:20:00 1 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 125 0 125 255 8.5 0 8.5 8.5 08/30/2005 05:30:00 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 125 0 125 255 8.5 0 8.8 8.5 08/30/2005 05:40:00 1.5 0.3 2.3 0.7 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 136 3 135 255 8.5 0 8.8 8.5 08/30/2005 05:50:00 1.3 0.2 1.9 0.7 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 135 0 135 255 8.4 0 8.5 8.5 08/30/2005 06:00:00 1.8 0.3 2.3 1.5 1.4 0.3 2.3 0.7 0.7 0.4 1.9 0.4 146 6 143 255 8.4 0 8.5 8.5 08/30/2005 06:10:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 150 0 150 255 8.4 0 8.5 8.5 08/30/2005 06:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 13 113 255 8.5 0 8.8 8.5 08/30/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 255 255 8.7 0 8.8 8.5 08/30/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 255 255 8.9 0 9 8.8 08/30/2005 06:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 91 0 91 255 9 0 9 9 08/30/2005 07:00:00 1.2 0.4 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.2 1.5 0.4 118 14 131 255 9.1 0 9.3 9 08/30/2005 07:10:00 1.6 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 128 12 154 255 9.4 0 9.6 9.3 08/30/2005 07:20:00 0.9 0.6 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.5 0.4 112 5 110 255 9.8 0 10.1 9.6 08/30/2005 07:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 117 0 117 255 10.2 0.1 10.6 9.8 08/30/2005 07:40:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 12 83 255 10.7 0.1 10.9 10.6 08/30/2005 07:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 77 21 52 255 11 0 11.1 10.9 08/30/2005 08:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 0 70 255 11.1 0 11.4 11.1 08/30/2005 08:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 31 10 28 255 11.3 0.1 11.7 11.1 08/30/2005 08:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 26 9 25 255 12.4 0.6 13.3 11.7 08/30/2005 08:30:00 0.9 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.3 1.5 0.4 9 36 12 255 13.7 0.2 13.8 13.3 08/30/2005 08:40:00 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 17 10 7 255 14.1 0 14.6 13.8 08/30/2005 08:50:00 1.5 0.4 2.6 0.4 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 358 12 357 255 15.1 0.3 15.7 14.6 08/30/2005 09:00:00 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 1 0.5 2.3 0.4 0 15 22 255 15.7 0.1 16.3 15.7 08/30/2005 09:10:00 1.2 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.4 2.3 0.4 359 24 358 255 16.1 0.1 16.8 16 08/30/2005 09:20:00 1.2 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 73 47 64 255 16.1 0.2 16.8 15.7 08/30/2005 09:30:00 1.1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1 0.4 2.3 0.4 114 30 155 255 15.8 0 16.3 15.7 08/30/2005 09:40:00 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 168 35 204 255 15.3 0.3 16 14.9 08/30/2005 09:50:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 206 22 208 255 14.2 0.3 15.2 13.8 08/30/2005 10:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 195 19 202 255 13.7 0 14.4 13.5 08/30/2005 10:10:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 166 14 168 255 13.8 0 14.4 13.5 08/30/2005 10:20:00 0.7 0.4 1.9 0.4 0.5 0.2 1.9 0.4 0.4 0.1 1.1 0.4 246 51 269 255 14.2 0.1 14.9 13.8 08/30/2005 10:30:00 0.9 0.6 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 201 29 215 255 14.8 0.4 16.3 14.4 08/30/2005 10:40:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.4 1.9 0.4 218 82 152 255 16.1 0.2 16.8 15.7 08/30/2005 10:50:00 2.1 0.9 4.2 0.4 1.8 1 4.2 0.4 1.5 1 3.8 0.4 293 72 300 255 16.1 0 16.8 16 08/30/2005 11:00:00 2.8 0.7 4.2 1.1 2.5 0.7 3.8 0.7 2.2 0.8 4.6 0.4 314 22 325 255 16.1 0.1 16.8 15.7 08/30/2005 11:10:00 1.7 0.7 3.4 0.4 1.4 0.7 3.8 0.4 1.3 0.8 3.4 0.4 289 33 300 255 16.3 0.4 16.8 15.7 08/30/2005 11:20:00 2.9 0.8 4.6 0.4 2.9 0.8 4.6 0.4 2.6 1 4.6 0.4 297 18 298 255 16.4 0.1 16.8 16 08/30/2005 11:30:00 1.8 0.8 4.2 0.4 1.8 0.8 4.2 0.4 1.4 0.8 3.8 0.4 297 36 274 255 16.1 0.1 16.6 16 08/30/2005 11:40:00 2.2 0.7 3.8 0.4 2.1 0.7 4.2 0.4 1.7 0.8 4.6 0.4 309 17 302 255 16.1 0 16.6 15.7 08/30/2005 11:50:00 2.3 0.9 4.2 0.4 2.3 0.9 4.2 0.4 1.8 1 4.2 0.4 303 28 313 255 16.3 0.3 16.8 15.7 08/30/2005 12:00:00 2.9 0.6 4.6 1.5 2.8 0.7 4.6 1.5 2.3 1 4.6 0.4 311 23 276 255 16.6 0 16.8 16.3 08/30/2005 12:10:00 2 1 3.8 0.4 2.1 0.9 3.8 0.4 1.8 1 4.2 0.4 314 22 295 255 16.8 0 16.8 16.6 08/30/2005 12:20:00 1.6 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.5 0.8 3.4 0.4 314 23 297 255 16.7 0.2 17.1 16.3 08/30/2005 12:30:00 1.7 0.7 3.4 0.4 2 0.6 3.4 0.4 1.7 0.8 3.4 0.4 299 11 302 255 15.9 0 16.3 15.7 08/30/2005 12:40:00 1.6 0.8 3.4 0.4 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 305 18 299 255 15.9 0 16.3 15.7 08/30/2005 12:50:00 1.3 0.9 3 0.4 1.7 0.7 3.4 0.4 1.7 0.7 3.4 0.4 311 19 349 255 15.8 0.1 16.3 15.7 08/30/2005 13:00:00 1.3 0.8 3 0.4 1.6 0.8 3 0.4 1.3 0.8 3.4 0.4 318 30 290 255 15.7 0 16 15.7 08/30/2005 13:10:00 1 0.8 2.6 0.4 1.2 0.7 3.4 0.4 0.9 0.6 2.6 0.4 337 21 344 255 16.1 0 16.3 16 08/30/2005 13:20:00 1.2 0.7 3 0.4 1.4 0.6 3 0.4 1.4 0.6 3 0.4 314 17 291 255 15.9 0.1 16.3 15.7 08/30/2005 13:30:00 0.9 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.1 0.6 2.6 0.4 311 10 333 255 15.6 0 16 15.5 08/30/2005 13:40:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 312 15 318 255 15.8 0.1 16.3 15.7 08/30/2005 13:50:00 0.5 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 288 21 321 255 16.1 0 16.8 16 08/30/2005 14:00:00 0.6 0.5 2.3 0.4 0.8 0.6 2.6 0.4 0.8 0.5 2.3 0.4 276 17 298 255 16.1 0 16.8 16 08/30/2005 14:10:00 0.4 0.2 1.5 0.4 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 329 45 28 255 16.4 0.2 16.8 16.3 08/30/2005 14:20:00 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 288 56 303 255 17.1 0 17.4 16.8 08/30/2005 14:30:00 0.4 0.3 1.9 0.4 0.6 0.5 3 0.4 0.6 0.4 3 0.4 214 16 231 255 16.7 0.2 17.1 16.6 08/30/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 202 0 255 255 16.4 0 16.6 16.3 08/30/2005 14:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 228 21 255 255 16.1 0 16.6 16 08/30/2005 15:00:00 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 241 26 255 255 15.9 0 16.3 15.7 08/30/2005 15:10:00 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 230 11 249 255 15.5 0 16.3 15.2 08/30/2005 15:20:00 0.6 0.4 1.9 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 213 14 218 255 15.2 0.1 15.7 14.9 08/30/2005 15:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 211 8 255 255 14.8 0 15.5 14.6 08/30/2005 15:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 203 9 255 255 14.8 0 15.2 14.6 08/30/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 211 24 255 255 14.8 0 15.2 14.6 08/30/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 255 255 15 0 15.7 14.9 08/30/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 3 255 255 15.2 0.1 15.7 15.2 08/30/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 255 255 15.3 0.1 15.7 15.2 08/30/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 255 255 15.4 0 16 15.2 08/30/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 255 255 15.5 0 16 15.5 08/30/2005 16:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 293 21 255 255 15.3 0.1 15.7 15.2 08/30/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 15 0 15.5 14.9 08/30/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 15 0 15.5 14.9 08/30/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 14.9 0 15.5 14.9 08/30/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 14.9 0 15.5 14.9 08/30/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 14.8 0 15.2 14.9 08/30/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 14.8 0 15.2 14.9 08/30/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 14.7 0 15.2 14.6 08/30/2005 18:10:00 0.4 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 39 66 56 255 14.6 0 15.2 14.6 08/30/2005 18:20:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 49 22 72 255 14.5 0 15.2 14.4 08/30/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 41 255 255 14.4 0 14.9 14.4 08/30/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 255 255 14.2 0 14.6 14.4 08/30/2005 18:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 188 2 255 255 14.2 0 14.6 14.1 08/30/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 0 255 255 14.1 0.1 14.6 14.1 08/30/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 153 82 255 255 14 0.1 14.6 13.8 08/30/2005 19:20:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 49 21 44 255 13.8 0 14.4 13.5 08/30/2005 19:30:00 1 0.5 1.9 0.4 1.4 0.5 2.3 0.4 1 0.5 1.9 0.4 23 8 32 255 13.5 0 14.1 13.3 08/30/2005 19:40:00 0.5 0.2 1.5 0.4 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 37 18 14 255 13.3 0 13.8 13 08/30/2005 19:50:00 0.6 0.4 1.5 0.4 1.2 0.4 1.9 0.4 0.9 0.5 1.9 0.4 63 9 79 255 13 0.1 13.5 12.7 08/30/2005 20:00:00 0.5 0.3 1.5 0.4 1.1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 64 6 64 255 12.8 0 13.3 12.7 08/30/2005 20:10:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 60 12 66 255 12.5 0 12.7 12.5 08/30/2005 20:20:00 0.4 0.1 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.1 0.4 46 10 40 255 12.3 0 12.5 12.2 08/30/2005 20:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 58 23 255 255 12.1 0 12.2 11.9 08/30/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 255 255 11.9 0 11.9 11.7 08/30/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 70 24 255 255 11.8 0 11.9 11.7 08/30/2005 21:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 85 0 255 255 11.7 0 11.7 11.7 08/30/2005 21:10:00 0.5 0.3 1.5 0.4 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 82 3 81 255 11.7 0 11.7 11.7 08/30/2005 21:20:00 0.9 0.6 2.3 0.4 1.4 0.4 2.6 0.7 0.7 0.4 1.9 0.4 57 10 68 255 11.5 0 11.7 11.4 08/30/2005 21:30:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 58 3 46 255 11.3 0 11.4 11.1 08/30/2005 21:40:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 62 5 60 255 11.1 0 11.4 11.1 08/30/2005 21:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 67 0 255 255 11.1 0 11.1 11.1 08/30/2005 22:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 67 0 255 255 11.1 0 11.4 11.1 08/30/2005 22:10:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 57 6 56 255 11.1 0 11.4 11.1 08/30/2005 22:20:00 1 0.5 2.3 0.4 1.3 0.4 2.6 0.4 0.7 0.4 1.5 0.4 50 11 50 255 11.1 0 11.4 11.1 08/30/2005 22:30:00 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 48 12 34 255 11.1 0 11.4 11.1 08/30/2005 22:40:00 0.8 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 49 12 63 255 11.1 0 11.1 11.1 08/30/2005 22:50:00 1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 0.8 0.5 2.3 0.4 54 12 88 255 11.1 0 11.1 11.1 08/30/2005 23:00:00 1 0.6 2.3 0.4 1.3 0.5 2.6 0.4 0.7 0.4 1.9 0.4 64 15 62 255 11.1 0 11.1 11.1 08/30/2005 23:10:00 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 64 11 62 255 11 0 11.1 10.9 08/30/2005 23:20:00 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.6 0.3 1.9 0.4 56 12 58 255 10.9 0 11.1 10.9 08/30/2005 23:30:00 1.5 0.6 3 0.4 1.7 0.5 3 0.4 0.9 0.5 2.3 0.4 58 9 39 255 10.9 0 11.1 10.9 08/30/2005 23:40:00 1.6 0.6 2.6 0.4 1.7 0.5 3 0.4 1 0.4 1.9 0.4 64 8 83 255 10.9 0 11.1 10.9 08/30/2005 23:50:00 1.7 0.5 3 0.4 1.8 0.4 3 0.7 0.9 0.4 1.9 0.4 65 10 76 255 11 0 11.1 10.9 08/31/2005 00:00:00 1.3 0.6 3 0.4 1.5 0.5 3 0.4 0.6 0.4 1.9 0.4 59 12 90 255 10.9 0 11.7 10.9 08/31/2005 00:10:00 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.8 0.4 1.9 0.4 56 6 53 255 11.1 0 11.1 11.1 08/31/2005 00:20:00 1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 56 10 46 255 11.1 0 11.1 11.1 08/31/2005 00:30:00 0.9 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 36 9 39 255 11.1 0 11.1 11.1 08/31/2005 00:40:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 4 13 356 255 11.1 0 11.1 11.1 08/31/2005 00:50:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.4 0.6 0.4 1.9 0.4 18 12 8 255 10.9 0 11.1 10.9 08/31/2005 01:00:00 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 49 10 55 255 10.9 0 11.1 10.9 08/31/2005 01:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 79 26 109 255 10.7 0.1 10.9 10.6 08/31/2005 01:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 116 13 110 255 10.6 0 10.6 10.6 08/31/2005 01:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 121 12 112 255 10.5 0 10.6 10.3 08/31/2005 01:40:00 1.5 0.3 2.3 0.7 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 131 9 144 255 10.3 0 10.6 10.3 08/31/2005 01:50:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 126 9 125 255 10.2 0 10.3 10.3 08/31/2005 02:00:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 110 22 136 255 10.3 0 10.3 10.3 08/31/2005 02:10:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.2 1.9 0.4 97 13 117 255 10.2 0 10.3 10.1 08/31/2005 02:20:00 1.4 0.4 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 115 11 104 255 10 0 10.1 9.8 08/31/2005 02:30:00 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 118 13 127 255 9.8 0 9.8 9.8 08/31/2005 02:40:00 1.4 0.4 2.6 0.4 0.9 0.4 2.3 0.4 0.5 0.3 1.5 0.4 123 11 132 255 9.7 0 9.8 9.6 08/31/2005 02:50:00 1.3 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.4 0.1 1.1 0.4 115 12 109 255 9.6 0 9.8 9.6 08/31/2005 03:00:00 1.4 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 82 8 89 255 9.6 0 9.6 9.6 08/31/2005 03:10:00 1.1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 38 17 31 255 9.4 0 9.6 9.3 08/31/2005 03:20:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 11 31 255 9.3 0 9.6 9.3 08/31/2005 03:30:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 80 17 95 255 9.5 0 9.6 9.3 08/31/2005 03:40:00 1.6 0.3 2.3 0.7 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 101 6 110 255 9.5 0 9.6 9.6 08/31/2005 03:50:00 2.4 0.2 2.6 1.9 2 0.2 2.3 1.5 0.6 0.3 1.5 0.4 103 6 103 255 9.5 0 9.6 9.3 08/31/2005 04:00:00 2.5 0.3 3 1.5 2.2 0.3 3 1.1 1.1 0.5 2.3 0.4 95 8 91 255 9.5 0 9.6 9.3 08/31/2005 04:10:00 1.9 0.7 3 0.4 1.6 0.7 2.6 0.4 0.6 0.4 1.9 0.4 92 14 101 255 9.5 0 9.6 9.6 08/31/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 255 255 9.7 0.1 9.8 9.6 08/31/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 255 255 9.6 0 9.8 9.6 08/31/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 255 255 9.5 0 9.6 9.6 08/31/2005 04:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 30 49 255 9.6 0 9.8 9.6 08/31/2005 05:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 77 26 104 255 9.7 0 9.8 9.6 08/31/2005 05:10:00 1.6 0.3 2.3 0.7 1.2 0.3 1.9 0.4 0.4 0 0.4 0.4 85 10 82 255 9.7 0 9.8 9.6 08/31/2005 05:20:00 1.4 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0 0.7 0.4 87 11 83 255 9.7 0 9.8 9.6 08/31/2005 05:30:00 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 75 15 67 255 9.8 0 9.8 9.8 08/31/2005 05:40:00 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 107 7 113 255 9.9 0 10.1 9.8 08/31/2005 05:50:00 0.8 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 96 11 73 255 10 0 10.1 9.8 08/31/2005 06:00:00 1.4 0.3 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 96 11 68 255 10.1 0 10.3 10.1 08/31/2005 06:10:00 1.6 0.3 2.3 0.4 1 0.4 1.9 0.4 0.5 0.2 1.5 0.4 96 10 110 255 10.2 0 10.3 10.1 08/31/2005 06:20:00 1.3 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 112 13 96 255 10.3 0 10.6 10.3 08/31/2005 06:30:00 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 102 12 100 255 10.5 0 10.6 10.3 08/31/2005 06:40:00 1.8 0.3 2.6 1.1 1.4 0.3 2.3 0.4 0.7 0.4 1.5 0.4 96 9 100 255 10.6 0 10.6 10.6 08/31/2005 06:50:00 1.5 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 107 16 94 255 10.6 0 10.9 10.6 08/31/2005 07:00:00 1.3 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 87 15 76 255 10.6 0 10.9 10.6 08/31/2005 07:10:00 1.5 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.4 0.3 1.5 0.4 79 10 67 255 10.7 0 10.9 10.6 08/31/2005 07:20:00 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 86 5 81 255 10.6 0 10.9 10.6 08/31/2005 07:30:00 1.5 0.3 2.3 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.5 0.4 76 9 78 255 10.6 0 10.9 10.6 08/31/2005 07:40:00 1.6 0.5 2.3 0.4 1.1 0.4 1.9 0.4 0.4 0.2 1.5 0.4 72 6 73 255 10.6 0 10.9 10.6 08/31/2005 07:50:00 1 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 73 18 48 255 10.7 0 10.9 10.6 08/31/2005 08:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 90 255 10.7 0 10.9 10.6 08/31/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 32 255 255 10.7 0 10.9 10.6 08/31/2005 08:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 18 34 255 10.8 0 10.9 10.9 08/31/2005 08:30:00 1.2 0.4 1.9 0.4 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 30 11 17 255 10.9 0 10.9 10.9 08/31/2005 08:40:00 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 12 7 37 255 10.9 0 11.1 10.9 08/31/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 255 255 10.9 0 10.9 10.9 08/31/2005 09:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 15 41 255 10.9 0 11.1 10.9 08/31/2005 09:10:00 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 46 6 53 255 10.9 0 11.1 10.9 08/31/2005 09:20:00 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 39 12 53 255 11.1 0 11.1 10.9 08/31/2005 09:30:00 1.4 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 27 6 28 255 11.2 0 11.4 11.1 08/31/2005 09:40:00 1.3 0.3 1.9 0.7 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 32 17 27 255 11.3 0 11.4 11.1 08/31/2005 09:50:00 0.8 0.6 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 70 13 71 255 11.5 0 11.7 11.4 08/31/2005 10:00:00 1.3 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 81 9 79 255 11.7 0 11.7 11.7 08/31/2005 10:10:00 1.4 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 73 8 77 255 11.8 0 11.9 11.7 08/31/2005 10:20:00 1.3 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 79 14 69 255 12.1 0 12.2 11.9 08/31/2005 10:30:00 1.3 0.3 2.3 0.7 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 74 7 79 255 12.3 0 12.5 12.2 08/31/2005 10:40:00 1.6 0.3 2.6 0.7 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 79 12 89 255 12.3 0 12.5 12.2 08/31/2005 10:50:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 78 4 77 255 12.3 0 12.5 12.2 08/31/2005 11:00:00 1.3 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.6 0.3 1.1 0.4 72 4 69 255 12.4 0 12.5 12.5 08/31/2005 11:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 62 9 62 255 12.5 0 12.7 12.5 08/31/2005 11:20:00 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 45 16 52 255 12.7 0 12.7 12.5 08/31/2005 11:30:00 0.9 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 18 7 19 255 12.8 0 12.7 12.7 08/31/2005 11:40:00 1.3 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 10 7 17 255 12.9 0 13 12.7 08/31/2005 11:50:00 1.4 0.3 2.3 0.4 0.9 0.3 1.9 0.4 0.5 0.3 1.5 0.4 18 15 20 255 12.9 0 13 12.7 08/31/2005 12:00:00 1.7 0.3 2.6 0.7 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 44 18 51 255 12.9 0 13 12.7 08/31/2005 12:10:00 1.8 0.3 2.3 1.1 1.4 0.4 2.3 0.4 0.9 0.5 1.9 0.4 35 11 30 255 12.9 0 13 12.7 08/31/2005 12:20:00 1.5 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 34 11 42 255 13 0 13.3 12.7 08/31/2005 12:30:00 1.6 0.3 2.3 0.7 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 55 8 60 255 13.1 0 13 13 08/31/2005 12:40:00 1.2 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 48 17 44 255 13.1 0 13.3 13 08/31/2005 12:50:00 1.2 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 3 11 19 255 13.3 0 13.5 13 08/31/2005 13:00:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 14 7 8 255 13.3 0 13.5 13.3 08/31/2005 13:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 15 4 8 255 13.4 0 13.5 13.3 08/31/2005 13:20:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 29 12 29 255 13.6 0 13.5 13.5 08/31/2005 13:30:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 20 6 20 255 13.7 0 13.8 13.5 08/31/2005 13:40:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 3 8 3 255 13.8 0 13.8 13.5 08/31/2005 13:50:00 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 6 17 31 255 13.9 0 14.4 13.8 08/31/2005 14:00:00 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 14 10 358 255 13.8 0 14.4 13.5 08/31/2005 14:10:00 1.1 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.4 0.1 1.1 0.4 7 8 15 255 13.7 0 14.1 13.5 08/31/2005 14:20:00 1.8 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.8 0.5 1.9 0.4 8 7 16 255 13.7 0 14.1 13.5 08/31/2005 14:30:00 1.8 0.4 2.6 0.4 1.3 0.5 2.3 0.4 0.8 0.5 1.9 0.4 9 12 11 255 13.5 0 13.8 13.5 08/31/2005 14:40:00 2.1 0.3 3 1.5 1.7 0.4 2.6 0.7 1.2 0.6 2.6 0.4 14 7 17 255 13.9 0 13.8 13.5 08/31/2005 14:50:00 1.6 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 21 9 17 255 14.1 0.1 14.9 13.8 08/31/2005 15:00:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 34 27 1 255 14.2 0 14.9 14.1 08/31/2005 15:10:00 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 41 27 49 255 14.4 0 14.9 14.1 08/31/2005 15:20:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 34 15 32 255 14.4 0 14.9 14.4 08/31/2005 15:30:00 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 24 15 12 255 14.2 0 14.6 14.1 08/31/2005 15:40:00 2.2 0.4 3 1.1 2 0.4 3 0.7 1.2 0.6 2.6 0.4 10 13 14 255 14.4 0 14.6 14.4 08/31/2005 15:50:00 2.5 0.4 3 1.1 2.3 0.4 3 1.1 1.4 0.6 3 0.4 11 7 11 255 14.4 0 14.6 14.4 08/31/2005 16:00:00 2 0.3 3 1.1 2 0.3 2.6 0.7 1 0.5 2.3 0.4 9 14 24 255 14.4 0 14.6 14.4 08/31/2005 16:10:00 2.6 0.4 3.4 1.5 2.5 0.5 3.4 1.1 1.5 0.7 3.4 0.4 19 12 22 255 14.5 0 14.6 14.4 08/31/2005 16:20:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.7 0.8 3 0.4 15 9 21 255 14.3 0 14.6 14.1 08/31/2005 16:30:00 2.4 0.5 4.2 1.1 2.5 0.5 3.8 1.1 1.1 0.7 2.6 0.4 10 9 25 255 13.9 0 14.6 13.8 08/31/2005 16:40:00 2.6 0.6 3.8 0.4 2.6 0.6 3.8 0.4 1.4 0.8 3 0.4 20 17 15 255 13.9 0 14.4 13.8 08/31/2005 16:50:00 1.8 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.1 0.7 3 0.4 52 16 53 255 13.9 0 14.4 13.5 08/31/2005 17:00:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 1.6 0.6 2.6 0.4 46 13 44 255 13.5 0 13.8 13.3 08/31/2005 17:10:00 0.7 0.6 2.3 0.4 0.7 0.6 2.6 0.4 0.4 0.3 1.5 0.4 71 49 36 255 13.1 0.1 13.5 12.7 08/31/2005 17:20:00 1.4 0.7 2.6 0.4 1.5 0.8 2.6 0.4 0.6 0.5 2.3 0.4 39 47 7 255 12.7 0 13.3 12.5 08/31/2005 17:30:00 1.5 0.4 2.6 0.4 1.7 0.4 2.6 0.7 0.5 0.3 1.5 0.4 7 9 4 255 12.4 0.1 13 12.5 08/31/2005 17:40:00 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 15 7 22 255 12.4 0 12.5 12.5 08/31/2005 17:50:00 1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.4 0.2 1.5 0.4 13 16 53 255 12.4 0 12.5 12.5 08/31/2005 18:00:00 0.8 0.4 1.9 0.4 1 0.5 1.9 0.4 0.4 0.2 1.5 0.4 34 15 11 255 12.3 0 12.7 12.2 08/31/2005 18:10:00 1.1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.5 0.3 1.5 0.4 26 16 22 255 12.3 0 12.5 12.2 08/31/2005 18:20:00 0.9 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0.2 1.5 0.4 8 15 2 255 12.2 0 12.2 11.9 08/31/2005 18:30:00 2.2 0.4 3 1.1 2.3 0.4 3 1.1 1 0.6 2.6 0.4 11 9 17 255 12.1 0 12.2 11.9 08/31/2005 18:40:00 2 0.7 3.4 0.4 2 0.6 3 0.4 1.2 0.8 3 0.4 27 10 24 255 12 0 12.2 11.9 08/31/2005 18:50:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.9 0.5 1.9 0.4 27 26 59 255 11.8 0 11.9 11.7 08/31/2005 19:00:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 348 5 342 255 11.7 0 11.9 11.7 08/31/2005 19:10:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 23 23 43 255 11.7 0 11.7 11.7 08/31/2005 19:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 56 17 87 255 11.6 0 11.7 11.4 08/31/2005 19:30:00 1.6 0.5 2.6 0.7 1.4 0.5 2.6 0.4 0.7 0.4 1.9 0.4 75 17 52 255 11.5 0 11.7 11.4 08/31/2005 19:40:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1 0.5 2.3 0.4 45 9 40 255 11.5 0 11.7 11.4 08/31/2005 19:50:00 2.1 0.6 3.4 0.7 1.9 0.7 3 0.4 1 0.6 2.6 0.4 13 28 26 255 11.5 0 11.7 11.4 08/31/2005 20:00:00 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 261 58 355 255 11.5 0 11.7 11.4 08/31/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 0 255 255 11.3 0 11.4 11.1 08/31/2005 20:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 0 204 255 11.1 0 11.4 11.1 08/31/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 0 255 255 11.1 0 11.1 11.1 08/31/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 116 30 255 255 11.1 0 11.1 10.9 08/31/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 255 255 10.9 0 11.1 10.9 08/31/2005 21:00:00 1.2 0.5 1.9 0.4 1 0.4 1.5 0.4 0.4 0.1 0.7 0.4 105 0 105 255 10.8 0 10.9 10.6 08/31/2005 21:10:00 1.3 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.4 0.2 1.1 0.4 116 7 119 255 10.6 0 10.9 10.6 08/31/2005 21:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 101 19 87 255 10.6 0 10.9 10.6 08/31/2005 21:30:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.5 0.3 1.9 0.4 104 9 94 255 10.5 0 10.6 10.6 08/31/2005 21:40:00 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.7 0.5 0.3 1.9 0.4 96 11 102 255 10.4 0 10.6 10.3 08/31/2005 21:50:00 1.4 0.3 1.9 0.4 1.3 0.4 2.3 0.4 0.4 0.2 1.1 0.4 98 5 89 255 10.3 0 10.6 10.3 08/31/2005 22:00:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 0.7 0.4 1.9 0.4 110 14 97 255 10.2 0 10.3 10.1 08/31/2005 22:10:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 125 8 121 255 10.1 0 10.3 10.1 08/31/2005 22:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 130 5 136 255 10.1 0 10.3 10.1 08/31/2005 22:30:00 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 125 0 125 255 10 0 10.1 9.8 08/31/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 125 0 255 255 9.9 0 10.1 9.8 08/31/2005 22:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.5 0.4 0.4 0 0.4 0.4 124 8 125 255 9.8 0 9.8 9.6 08/31/2005 23:00:00 2.5 0.6 3.8 1.1 2.5 0.6 3.8 0.7 1.3 0.7 2.6 0.4 269 13 267 255 9.9 0 10.1 9.6 08/31/2005 23:10:00 1.3 0.4 2.6 0.4 1.3 0.4 2.6 0.4 0.4 0.1 1.1 0.4 295 12 291 255 10 0 10.1 10.1 08/31/2005 23:20:00 0.9 0.3 1.5 0.4 1 0.3 1.9 0.4 0.4 0 0.4 0.4 294 5 289 255 10 0 10.1 9.8 08/31/2005 23:30:00 1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.4 0 0.4 0.4 305 10 300 255 9.8 0 9.8 9.8 08/31/2005 23:40:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 319 9 321 255 9.8 0 9.8 9.8 08/31/2005 23:50:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0 0.7 0.4 333 8 340 255 9.9 0 10.1 9.8 09/01/2005 00:00:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 330 0 330 255 10 0 10.1 9.8 09/01/2005 00:10:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 304 17 289 255 10.1 0 10.3 10.1 09/01/2005 00:20:00 1.1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.5 0.3 1.9 0.4 285 18 303 255 10.2 0 10.3 10.1 09/01/2005 00:30:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 0.4 0.2 1.9 0.4 259 27 250 255 10.2 0 10.3 10.1 09/01/2005 00:40:00 1.5 0.9 3.4 0.4 1.6 0.9 3.4 0.4 0.7 0.6 2.6 0.4 258 17 246 255 10.1 0 10.3 9.8 09/01/2005 00:50:00 1.2 0.3 2.3 0.4 1.2 0.3 2.3 0.4 0.4 0.1 1.1 0.4 225 20 247 255 10 0 10.1 9.8 09/01/2005 01:00:00 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 197 5 206 255 9.8 0 9.8 9.8 09/01/2005 01:10:00 0.8 0.3 1.5 0.4 1 0.3 1.9 0.4 0.4 0 0.4 0.4 188 16 196 255 9.8 0 9.8 9.8 09/01/2005 01:20:00 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 172 9 164 255 9.8 0 9.8 9.8 09/01/2005 01:30:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.4 0.2 1.5 0.4 156 6 154 255 9.8 0 9.8 9.6 09/01/2005 01:40:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 109 79 319 255 9.8 0 9.8 9.6 09/01/2005 01:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 319 0 255 255 9.6 0 9.8 9.6 09/01/2005 02:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0 17 255 255 9.5 0 9.6 9.6 09/01/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 0 255 255 9.5 0 9.6 9.3 09/01/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 0 255 255 9.5 0 9.6 9.3 09/01/2005 02:30:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 7 0 7 255 9.4 0 9.6 9.3 09/01/2005 02:40:00 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 7 0 7 255 9.3 0 9.6 9.3 09/01/2005 02:50:00 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 4 5 7 255 9.1 0 9.3 9 09/01/2005 03:00:00 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.5 0.3 1.9 0.4 330 13 321 255 9 0 9 9 09/01/2005 03:10:00 1.9 0.6 3.4 0.7 1.8 0.6 3.8 0.7 0.8 0.6 2.6 0.4 312 13 315 255 8.9 0 9 8.8 09/01/2005 03:20:00 2 0.5 3 0.4 2 0.5 3 1.1 1 0.6 2.3 0.4 283 13 290 255 8.5 0.1 8.8 8.3 09/01/2005 03:30:00 1.3 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.4 0.2 1.5 0.4 274 8 291 255 8.1 0.1 8.5 7.8 09/01/2005 03:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 275 255 7.6 0.1 7.8 7.3 09/01/2005 03:50:00 1 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 300 22 328 255 7.3 0 7.5 7 09/01/2005 04:00:00 0.9 0.3 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0 0.4 0.4 297 4 299 255 7 0.1 7.3 7 09/01/2005 04:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 290 0 290 255 6.9 0 7 6.7 09/01/2005 04:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 290 0 290 255 6.9 0 7 6.7 09/01/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 290 0 255 255 7.2 0 7.3 7 09/01/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 290 0 255 255 7.3 0 7.5 7.3 09/01/2005 04:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 300 29 28 255 7.4 0 7.5 7.3 09/01/2005 05:00:00 0.5 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 18 4 10 255 7.6 0 7.8 7.5 09/01/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 7.8 0 7.8 7.5 09/01/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 7.8 0 7.8 7.8 09/01/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 7.8 0 7.8 7.8 09/01/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 7.8 0 8 7.8 09/01/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 7.8 0 8 7.8 09/01/2005 06:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 17 255 7.8 0 8 7.8 09/01/2005 06:10:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.4 0 0.7 0.4 8 7 3 255 7.9 0 8 7.8 09/01/2005 06:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 3 0 3 255 7.9 0 8 7.8 09/01/2005 06:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 3 0 3 255 7.8 0 8 7.8 09/01/2005 06:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 3 0 3 255 7.8 0 7.8 7.8 09/01/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 3 0 3 255 7.6 0 7.8 7.5 09/01/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 255 255 7.7 0 7.8 7.5 09/01/2005 07:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 3 0 3 255 7.9 0 8 7.8 09/01/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 3 0 3 255 8 0 8.3 8 09/01/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 255 255 8.1 0 8.3 8.3 09/01/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 255 255 8.1 0 8.3 8 09/01/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 255 255 8.3 0 8.5 8.3 09/01/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 255 255 8.3 0 8.5 8.3 09/01/2005 08:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 9 11 9 255 8.7 0.2 9.3 8.5 09/01/2005 08:20:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 19 11 24 255 10 0.4 10.6 9.3 09/01/2005 08:30:00 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 354 23 318 255 11 0.2 11.4 10.6 09/01/2005 08:40:00 1.1 0.4 2.3 0.4 1.4 0.4 2.6 0.7 0.9 0.4 2.3 0.4 312 9 308 255 10.7 0 11.1 10.6 09/01/2005 08:50:00 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.9 0.6 2.3 0.4 304 12 292 255 11.1 0.2 11.4 10.6 09/01/2005 09:00:00 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 306 13 321 255 11.4 0.2 12.2 11.1 09/01/2005 09:10:00 1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 344 24 13 255 12.2 0.1 12.7 11.9 09/01/2005 09:20:00 1.5 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.2 0.5 2.3 0.4 318 13 321 255 11.8 0.1 12.5 11.7 09/01/2005 09:30:00 0.8 0.6 3 0.4 0.9 0.6 3 0.4 0.8 0.5 2.3 0.4 313 10 313 255 11.9 0.1 12.5 11.7 09/01/2005 09:40:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.3 0.7 3 0.4 311 14 287 255 12.1 0.2 12.7 11.7 09/01/2005 09:50:00 2.2 0.7 3.8 0.7 2.1 0.7 3.4 0.7 1.7 0.8 3.8 0.4 310 15 304 255 12.5 0.1 12.7 12.2 09/01/2005 10:00:00 1.8 0.6 3 0.4 1.7 0.7 3.4 0.4 1.5 0.6 3 0.4 307 13 285 255 11.6 0.3 12.5 11.1 09/01/2005 10:10:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.7 0.5 2.6 0.4 312 28 327 255 11.2 0.1 11.7 10.9 09/01/2005 10:20:00 2.1 0.6 3.4 0.4 1.8 0.5 3 0.4 1.3 0.8 3 0.4 338 17 356 255 11.7 0 12.2 11.7 09/01/2005 10:30:00 2.3 0.5 3.4 0.7 1.9 0.5 3 0.4 1.9 0.7 3 0.4 340 9 320 255 11.5 0.1 12.2 11.4 09/01/2005 10:40:00 1.8 0.6 3.8 0.4 1.6 0.6 3.4 0.4 1 0.6 2.6 0.4 329 26 350 255 12.2 0.3 12.7 11.7 09/01/2005 10:50:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.1 0.7 2.6 0.4 357 23 348 255 12.9 0.1 13.3 12.7 09/01/2005 11:00:00 1.3 0.8 3 0.4 1.3 0.8 3.4 0.4 0.9 0.6 3.4 0.4 307 43 22 255 12.9 0.1 13.3 12.7 09/01/2005 11:10:00 2 1 3.8 0.4 1.9 0.9 4.2 0.4 1.4 0.9 3.8 0.4 293 30 294 255 12.9 0.3 13.8 12.2 09/01/2005 11:20:00 2.5 0.6 4.2 1.1 2.5 0.7 4.2 1.1 1.9 0.7 3.4 0.4 265 16 249 255 12.1 0.2 12.7 11.7 09/01/2005 11:30:00 2.6 0.6 4.6 0.7 2.4 0.6 4.6 0.4 2.2 0.8 4.6 0.4 309 21 295 255 12.7 0.2 13.3 12.2 09/01/2005 11:40:00 2.1 0.8 4.2 0.4 1.9 0.9 4.2 0.4 1.4 0.8 3.4 0.4 301 56 331 255 13.4 0.3 14.1 12.7 09/01/2005 11:50:00 2.1 0.7 4.2 0.4 1.9 0.8 4.2 0.4 1.4 0.7 3.4 0.4 331 33 333 255 13.7 0 14.4 13.3 09/01/2005 12:00:00 2.7 0.8 4.6 0.7 2.5 0.8 4.6 0.4 2.1 1 4.6 0.4 323 22 327 255 13.9 0 14.6 13.5 09/01/2005 12:10:00 2.6 0.8 4.2 0.4 2.4 0.8 4.2 0.4 1.9 0.9 3.8 0.4 317 53 350 255 14 0.1 14.6 13.5 09/01/2005 12:20:00 2.6 0.8 4.6 0.4 2.4 0.8 4.6 0.4 2.1 0.9 4.2 0.4 312 23 333 255 14.2 0.1 14.6 13.8 09/01/2005 12:30:00 1.9 0.9 4.2 0.4 1.8 0.9 4.2 0.4 1.4 0.9 3.8 0.4 347 43 302 255 14.3 0.1 15.2 13.8 09/01/2005 12:40:00 1.9 0.7 4.2 0.4 1.7 0.8 3.8 0.4 1.3 0.9 4.6 0.4 311 20 293 255 14.6 0.1 15.2 14.6 09/01/2005 12:50:00 1.6 0.9 4.6 0.4 1.6 0.9 4.6 0.4 1.2 0.9 3.8 0.4 270 58 293 255 15.2 0.1 15.7 14.6 09/01/2005 13:00:00 2.9 0.9 4.9 0.7 2.6 0.9 4.9 0.4 2.3 0.9 4.9 0.4 343 24 306 255 15.4 0 15.7 15.5 09/01/2005 13:10:00 2.4 0.9 4.6 0.4 2.2 0.9 4.6 0.4 2 0.7 3.4 0.7 324 24 305 255 15.3 0 15.7 15.2 09/01/2005 13:20:00 2 0.8 4.2 0.4 1.8 0.8 3.8 0.4 1.2 0.7 3.8 0.4 311 26 315 255 15 0.1 15.7 14.9 09/01/2005 13:30:00 2.6 0.7 4.6 0.7 2.5 0.8 4.6 0.7 1.8 0.8 4.2 0.4 298 22 285 255 14.9 0 15.7 14.6 09/01/2005 13:40:00 1.5 1 3.8 0.4 1.4 0.9 3.4 0.4 1.2 0.9 3.4 0.4 283 39 305 255 15.3 0.4 16.3 14.6 09/01/2005 13:50:00 1.9 1 4.2 0.4 1.7 1 4.2 0.4 1.2 0.9 3.4 0.4 291 33 266 255 15.2 0.3 16 14.6 09/01/2005 14:00:00 2.4 0.7 4.2 0.4 2.3 0.7 4.2 0.7 1.9 0.7 4.2 0.4 318 23 282 255 15.1 0.4 16 14.6 09/01/2005 14:10:00 2.5 0.8 4.6 0.4 2.5 0.8 4.2 0.4 2.1 1.1 4.6 0.4 300 22 268 255 15.4 0 15.7 15.2 09/01/2005 14:20:00 2.1 0.9 4.2 0.4 2.1 0.8 4.2 0.4 1.6 0.8 4.2 0.4 284 47 290 255 15.5 0 16 15.5 09/01/2005 14:30:00 2.5 0.6 3.8 1.1 2.5 0.6 3.8 1.1 1.8 0.8 3.8 0.4 281 27 297 255 14.8 0.2 15.5 14.4 09/01/2005 14:40:00 1.7 1 3.8 0.4 1.6 1 3.8 0.4 1.3 1 3.4 0.4 286 27 294 255 14.4 0.3 15.5 14.1 09/01/2005 14:50:00 1.4 1 3.8 0.4 1.3 1 3.8 0.4 0.8 0.6 2.6 0.4 14 102 277 255 15.2 0.2 15.7 14.9 09/01/2005 15:00:00 2.2 0.8 4.2 0.4 2 0.8 4.2 0.4 1.3 0.8 3.4 0.4 274 28 270 255 15.5 0.2 16 15.2 09/01/2005 15:10:00 1.5 0.7 3 0.4 1.4 0.7 3 0.4 0.9 0.6 2.6 0.4 268 38 298 255 15.5 0 16 15.2 09/01/2005 15:20:00 1.8 1.1 4.2 0.4 1.7 1.1 4.2 0.4 1.2 0.9 3 0.4 311 39 305 255 15.1 0 15.7 14.9 09/01/2005 15:30:00 1.8 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.1 0.8 3 0.4 331 22 339 255 14.8 0 15.2 14.6 09/01/2005 15:40:00 2.3 0.6 3.4 0.7 2.1 0.7 3.8 0.7 1.2 0.7 3.4 0.4 348 22 346 255 15.1 0.3 16 14.9 09/01/2005 15:50:00 1.9 0.9 3.4 0.4 1.7 0.9 3.4 0.4 0.9 0.7 2.6 0.4 38 76 329 255 15.7 0.4 16.6 14.9 09/01/2005 16:00:00 1.6 0.9 4.6 0.4 1.5 1 4.2 0.4 0.8 0.8 3.8 0.4 227 18 209 255 14.5 0.3 15.2 13.8 09/01/2005 16:10:00 5.9 1.9 10.3 1.9 5.8 1.9 10.7 1.9 4.2 1.5 8.8 0.7 212 18 189 255 13.1 0.7 14.6 11.7 09/01/2005 16:20:00 5 1.7 9.1 1.5 5.1 1.7 8.8 1.9 3.8 1.5 7.2 0.7 197 21 215 255 10.8 0.5 11.9 10.1 09/01/2005 16:30:00 2.1 0.7 4.6 0.4 2.2 0.8 4.6 0.4 1.2 0.6 3 0.4 164 22 121 255 10 0 10.6 9.8 09/01/2005 16:40:00 3.7 1.2 6.8 1.5 3.6 1.2 6.8 1.5 2.7 1.2 6.1 0.4 129 23 148 255 10.5 0.3 11.4 10.1 09/01/2005 16:50:00 1.9 0.6 3.4 0.4 1.8 0.6 3.8 0.4 1.1 0.5 2.3 0.4 35 56 124 255 10.8 0.1 11.4 10.6 09/01/2005 17:00:00 2.1 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1 0.7 3 0.4 351 29 312 255 10.6 0 10.9 10.6 09/01/2005 17:10:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.2 0.5 2.6 0.4 0 15 340 255 10.6 0 10.6 10.6 09/01/2005 17:20:00 2.5 0.3 3.4 1.5 2.4 0.3 3 1.5 1.5 0.6 2.6 0.4 27 9 23 255 10.6 0 10.6 10.6 09/01/2005 17:30:00 2 0.4 2.6 0.7 1.9 0.4 2.6 0.7 0.9 0.6 2.3 0.4 44 11 41 255 10.6 0 10.9 10.6 09/01/2005 17:40:00 0.8 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.4 0 1.1 0.4 42 17 14 255 10.7 0 10.9 10.6 09/01/2005 17:50:00 1.5 0.8 3.4 0.4 1.4 0.8 3.4 0.4 0.8 0.5 2.3 0.4 37 17 39 255 10.9 0 11.1 10.9 09/01/2005 18:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 300 19 17 255 10.9 0 11.1 10.9 09/01/2005 18:10:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.7 0.4 1.9 0.4 91 58 115 255 10.7 0 10.9 10.6 09/01/2005 18:20:00 2.2 0.4 3 1.1 2.2 0.5 3.4 1.1 1.4 0.5 2.6 0.4 124 13 116 255 10.6 0 10.6 10.6 09/01/2005 18:30:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 0.7 0.5 2.3 0.4 117 12 115 255 10.5 0 10.6 10.6 09/01/2005 18:40:00 2.5 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.3 0.5 2.6 0.4 132 11 119 255 10.5 0 10.6 10.6 09/01/2005 18:50:00 3 0.6 4.6 1.5 2.9 0.6 4.9 1.5 1.8 0.7 3.8 0.4 119 12 117 255 10.5 0 10.6 10.6 09/01/2005 19:00:00 2.1 0.8 3.8 0.4 2 0.8 3.8 0.4 1.1 0.7 3 0.4 120 15 103 255 10.5 0 10.6 10.3 09/01/2005 19:10:00 1.8 0.5 3 0.7 1.6 0.5 3 0.4 0.5 0.4 2.3 0.4 120 15 113 255 10.2 0 10.6 10.1 09/01/2005 19:20:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0.1 1.1 0.4 113 13 105 255 9.9 0 10.1 9.8 09/01/2005 19:30:00 1.9 0.5 3.8 1.1 1.9 0.5 3.4 0.7 0.8 0.5 2.3 0.4 107 36 16 255 9.7 0 9.8 9.6 09/01/2005 19:40:00 1.8 0.5 3 0.7 1.6 0.5 3 0.4 0.7 0.5 2.6 0.4 81 35 13 255 9.6 0 9.6 9.6 09/01/2005 19:50:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.1 0.6 2.6 0.4 97 9 90 255 9.5 0 9.6 9.6 09/01/2005 20:00:00 3.2 0.5 4.6 1.5 3.1 0.5 4.6 1.9 1.7 0.6 3.4 0.4 107 11 98 255 9.4 0 9.6 9.3 09/01/2005 20:10:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 1.5 2.1 0.7 4.2 0.4 111 13 109 255 9.4 0 9.6 9.3 09/01/2005 20:20:00 2.9 0.8 4.6 1.1 3 0.7 4.9 1.5 1.9 0.9 4.2 0.4 110 15 110 255 9.6 0.1 9.8 9.3 09/01/2005 20:30:00 3.7 1.1 7.6 1.1 3.8 1.1 8 1.5 2.8 0.9 6.1 1.1 108 17 125 255 9.6 0 9.6 9.6 09/01/2005 20:40:00 5.2 1.3 9.1 2.3 5.3 1.3 9.5 2.6 4.2 1.3 8 0.4 96 17 93 255 9.8 0 9.8 9.6 09/01/2005 20:50:00 4.9 1.7 8.8 0.4 4.9 1.6 9.1 1.1 4 1.5 8.4 0.4 95 23 90 255 9.7 0 9.8 9.6 09/01/2005 21:00:00 4.6 1.3 7.6 0.7 4.6 1.2 7.6 1.1 3.4 1.3 6.8 0.4 90 20 96 255 9.6 0 9.8 9.3 09/01/2005 21:10:00 4.5 1.2 8 1.5 4.6 1.1 7.2 1.5 3.5 1.2 6.5 0.4 95 20 99 255 9.4 0 9.6 9.3 09/01/2005 21:20:00 4.4 1.2 7.6 1.9 4.4 1 8 2.3 3.4 1.2 7.2 0.4 99 20 109 255 9.4 0 9.6 9.3 09/01/2005 21:30:00 4.7 1.2 8.8 1.5 4.7 1.2 8.8 1.9 3.9 1.2 8 0.7 91 18 67 255 9.2 0 9.3 9 09/01/2005 21:40:00 4.6 1.1 7.6 2.3 4.6 1 8 2.6 3.7 1 6.5 1.5 95 17 113 255 9.1 0 9.3 9 09/01/2005 21:50:00 4.6 1.3 8 1.5 4.7 1.2 7.6 1.9 3.7 1.3 6.8 0.7 92 17 63 255 9 0 9.3 9 09/01/2005 22:00:00 5.4 1.5 8.8 1.1 5.4 1.4 8.8 1.5 4.4 1.5 8.8 1.1 100 17 108 255 8.9 0 9 9 09/01/2005 22:10:00 4.6 1.3 8.4 0.7 4.7 1.3 8 0.7 3.7 1.2 7.6 0.4 96 21 78 255 8.9 0 9 9 09/01/2005 22:20:00 5.1 1.5 8.4 1.9 5.1 1.4 8 1.9 4.4 1.2 8 1.1 100 17 104 255 8.9 0 9 8.8 09/01/2005 22:30:00 4.4 1.2 8.4 1.1 4.5 1.2 8 1.5 3.4 1.3 6.8 0.4 101 18 93 255 8.8 0 9 8.5 09/01/2005 22:40:00 5.1 1.4 8.4 0.7 5.2 1.3 8 1.5 4.2 1.3 7.6 1.1 101 17 88 255 8.6 0 8.8 8.5 09/01/2005 22:50:00 4.8 1.2 7.6 1.9 5 1.1 7.6 2.3 4 1.3 6.8 1.5 103 16 107 255 8.5 0 8.8 8.5 09/01/2005 23:00:00 4.2 1.4 7.6 0.7 4.4 1.3 7.2 0.7 3.4 1.4 6.8 0.4 96 20 108 255 8.5 0 8.5 8.5 09/01/2005 23:10:00 4.5 1.1 7.6 1.9 4.6 1 8.4 1.9 3.5 1 6.1 0.7 96 13 81 255 8.4 0 8.5 8.5 09/01/2005 23:20:00 4.4 1.2 7.2 1.5 4.5 1 6.8 1.5 3.4 1.2 6.5 1.1 98 17 99 255 8.5 0 8.8 8.5 09/01/2005 23:30:00 4.4 1.6 8.4 0.4 4.5 1.5 8 0.7 3.5 1.4 6.8 0.7 102 18 89 255 8.4 0 8.5 8.3 09/01/2005 23:40:00 5.3 1.3 9.9 2.3 5.3 1.3 9.1 2.3 4.3 1.3 8.8 1.5 105 16 112 255 8.5 0 8.8 8.5 09/01/2005 23:50:00 4.2 1.1 7.6 1.5 4.3 1 7.6 1.5 3.4 1 6.1 0.4 108 17 48 255 8.5 0 8.8 8.5 09/02/2005 00:00:00 4.3 1.1 7.2 1.5 4.5 1 7.2 2.3 3.5 1 6.5 1.5 101 16 134 255 8.2 0 8.5 8.3 09/02/2005 00:10:00 4.8 1.4 8.4 0.7 4.8 1.3 8 1.1 3.8 1.3 7.6 0.7 101 18 89 255 8.3 0 8.5 8.3 09/02/2005 00:20:00 3.7 0.9 6.1 1.1 3.9 0.8 5.7 1.5 3 1 5.3 0.4 95 16 134 255 8.3 0 8.5 8 09/02/2005 00:30:00 3.1 1.1 6.1 0.4 3.2 1 6.1 0.4 2.3 1 5.3 0.4 107 22 85 255 8 0 8.3 7.8 09/02/2005 00:40:00 3.8 0.9 5.7 0.7 3.8 0.9 6.5 1.9 2.9 0.9 5.3 0.7 98 17 103 255 8 0 8.3 7.8 09/02/2005 00:50:00 3.4 0.8 6.1 1.1 3.6 0.8 6.1 1.5 2.8 0.9 5.3 1.1 102 17 122 255 7.9 0 8 7.8 09/02/2005 01:00:00 3.3 0.9 5.7 1.1 3.4 0.8 5.7 1.5 2.4 0.9 5.7 0.4 100 16 100 255 7.7 0.1 8 7.3 09/02/2005 01:10:00 3.6 1 5.7 1.1 3.8 0.9 6.5 1.9 2.8 1 5.7 0.4 105 16 93 255 7.6 0 7.8 7.5 09/02/2005 01:20:00 4 1.1 6.5 1.1 4.1 1 6.5 1.9 3.1 1.2 6.5 0.4 104 17 105 255 7.8 0 8 7.5 09/02/2005 01:30:00 3.7 0.9 6.5 1.5 3.8 0.9 6.5 1.1 2.9 1 6.1 0.4 106 15 121 255 7.8 0 8 7.8 09/02/2005 01:40:00 3.8 1.3 6.8 0.4 3.9 1.3 7.2 1.1 3 1.2 6.1 0.4 100 16 122 255 8 0 8.3 7.8 09/02/2005 01:50:00 3.6 1.1 7.2 1.1 3.7 1 6.8 1.5 2.7 1 5.7 0.4 95 18 97 255 7.9 0 8 7.8 09/02/2005 02:00:00 3.1 0.8 4.9 1.1 3.2 0.7 4.9 0.7 2.2 0.9 4.2 0.4 85 17 81 255 7.8 0 7.8 7.8 09/02/2005 02:10:00 2.6 1 5.3 0.4 2.8 1 5.3 0.4 1.8 1 4.9 0.4 83 22 83 255 7.6 0 7.8 7.5 09/02/2005 02:20:00 2.2 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.4 0.7 3.4 0.4 76 12 70 255 7.2 0 7.5 6.7 09/02/2005 02:30:00 2.2 0.6 3.8 1.1 2.2 0.6 3.4 1.1 1.1 0.6 3 0.4 80 9 82 255 6.1 0.3 7 5.7 09/02/2005 02:40:00 0.8 0.6 2.3 0.4 0.8 0.6 2.6 0.4 0.4 0.1 1.1 0.4 62 10 78 255 5.4 0.2 5.7 5 09/02/2005 02:50:00 1.2 0.8 2.6 0.4 1.2 0.8 2.6 0.4 0.4 0.2 1.5 0.4 87 23 125 255 4.9 0 5 4.8 09/02/2005 03:00:00 1.9 0.5 3.4 0.7 1.9 0.5 3.4 0.4 0.6 0.4 2.3 0.4 101 8 89 255 4.6 0 4.8 4.5 09/02/2005 03:10:00 0.9 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.4 0.3 1.9 0.4 53 51 88 255 4.3 0 4.8 4.3 09/02/2005 03:20:00 0.6 0.3 2.3 0.4 0.5 0.3 2.3 0.4 0.4 0.2 1.1 0.4 38 72 60 255 4 0 4.5 3.8 09/02/2005 03:30:00 0.5 0.4 2.3 0.4 0.5 0.4 2.6 0.4 0.4 0.2 2.3 0.4 297 35 42 255 3.7 0.1 4 3.5 09/02/2005 03:40:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 291 9 288 255 3.3 0 3.8 3.3 09/02/2005 03:50:00 1.3 0.6 2.3 0.4 1.2 0.7 2.3 0.4 0.8 0.5 1.9 0.4 48 36 70 255 3 0.1 3.5 2.8 09/02/2005 04:00:00 2.1 0.3 2.6 1.5 2.2 0.3 3 1.5 1.1 0.5 2.3 0.4 51 13 77 255 3 0.1 3.5 2.8 09/02/2005 04:10:00 1.4 0.6 2.6 0.4 1.4 0.6 2.6 0.4 0.6 0.3 1.5 0.4 42 8 35 255 3 0 3.5 2.8 09/02/2005 04:20:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 55 22 86 255 2.9 0 3.5 2.6 09/02/2005 04:30:00 1.3 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.6 0.3 1.5 0.4 57 10 42 255 2.9 0 3.5 2.6 09/02/2005 04:40:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 39 23 17 255 3.2 0 3.8 3 09/02/2005 04:50:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 88 53 136 255 3 0.1 3.5 2.8 09/02/2005 05:00:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.6 0.5 1.9 0.4 136 1 136 255 2.9 0 3.5 2.8 09/02/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 2.9 0 3 2.6 09/02/2005 05:20:00 1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 251 79 303 255 2.6 0 3 2.6 09/02/2005 05:30:00 1 0.5 2.3 0.4 0.9 0.6 2.6 0.4 0.4 0 0.4 0.4 291 13 273 255 2.3 0 2.6 2.3 09/02/2005 05:40:00 1.2 0.3 1.5 0.7 1.1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 225 32 233 255 2.3 0 2.6 2.3 09/02/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.3 1.9 0.4 149 9 186 255 2.3 0 2.3 2.1 09/02/2005 06:00:00 1.5 0.4 2.3 0.4 1.5 0.5 2.3 0.4 0.8 0.4 1.9 0.4 151 4 156 255 2.1 0 2.3 1.8 09/02/2005 06:10:00 1.9 0.3 2.6 1.1 2.1 0.2 2.6 1.5 1.2 0.4 1.9 0.4 165 6 167 255 2.4 0 2.6 2.3 09/02/2005 06:20:00 1.6 0.5 2.3 0.7 1.5 0.6 2.3 0.4 0.6 0.4 1.5 0.4 149 12 159 255 2.7 0 2.8 2.6 09/02/2005 06:30:00 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.4 0.2 1.1 0.4 122 8 133 255 2.7 0 2.8 2.6 09/02/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 255 255 2.9 0 2.8 2.8 09/02/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 255 255 2.9 0 3 2.8 09/02/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 255 255 3.2 0 3.5 2.8 09/02/2005 07:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 117 0 118 255 3.7 0.1 4 3.5 09/02/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 118 0 255 255 4.3 0.2 4.8 4 09/02/2005 07:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 118 0 118 255 4.8 0 5 4.5 09/02/2005 07:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 118 1 118 255 5.7 0.4 6.7 5 09/02/2005 07:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 56 43 115 255 7 0.1 7.3 6.7 09/02/2005 08:00:00 0.8 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.1 0.4 313 28 303 255 6.7 0.1 7.3 6.5 09/02/2005 08:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 307 0 307 255 6.9 0.2 7.5 6.7 09/02/2005 08:20:00 0.8 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 300 36 267 255 7.9 0.2 8.5 7.3 09/02/2005 08:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 335 17 313 255 8.9 0.3 9.3 8.3 09/02/2005 08:40:00 1.4 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.1 0.4 2.3 0.4 309 11 295 255 9.2 0 9.6 9 09/02/2005 08:50:00 1.4 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 304 22 317 255 9.8 0.1 10.1 9.3 09/02/2005 09:00:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.3 0.4 311 22 318 255 10.4 0.1 10.9 10.1 09/02/2005 09:10:00 1.9 0.5 3 0.4 1.8 0.5 3 0.4 1.2 0.5 3 0.4 307 20 327 255 10.7 0.1 10.9 10.6 09/02/2005 09:20:00 2.2 0.5 3.4 0.7 2.1 0.5 3 0.4 1.9 0.6 3 0.4 308 15 319 255 10.5 0 10.6 10.6 09/02/2005 09:30:00 1.8 0.5 3 0.4 1.7 0.6 3.4 0.4 1.4 0.7 2.6 0.4 310 13 308 255 10.7 0 11.1 10.6 09/02/2005 09:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 314 23 291 255 11 0 11.4 10.9 09/02/2005 09:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 318 30 295 255 10.9 0 11.4 10.9 09/02/2005 10:00:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 318 29 294 255 11.3 0.2 12.2 10.9 09/02/2005 10:10:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 326 17 297 255 11.9 0.1 12.5 11.7 09/02/2005 10:20:00 1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 39 79 53 255 12.3 0.3 13.3 11.9 09/02/2005 10:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 40 56 9 255 12.8 0.2 13.5 12.5 09/02/2005 10:40:00 1.4 0.7 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.7 2.6 0.4 18 64 323 255 13.3 0 13.8 13 09/02/2005 10:50:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 1.5 0.6 3 0.4 0 13 354 255 13.7 0.1 14.4 13.3 09/02/2005 11:00:00 2.5 0.6 3.8 0.7 2.5 0.6 3.8 0.7 2.1 0.7 3.4 0.4 11 16 7 255 13.5 0.1 14.1 13 09/02/2005 11:10:00 2.3 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.8 0.5 2.6 0.4 0 16 357 255 13.3 0.2 13.5 12.7 09/02/2005 11:20:00 2.1 0.6 3.4 0.4 2 0.6 3.8 0.4 1.7 0.6 3 0.4 348 16 2 255 12.9 0.1 13.3 12.7 09/02/2005 11:30:00 1.9 0.7 3.4 0.4 1.7 0.6 3 0.4 1.4 0.7 3 0.4 346 22 328 255 13.3 0.1 13.8 13 09/02/2005 11:40:00 2.1 0.6 3.4 0.7 1.8 0.5 3.4 0.7 1.7 0.6 3.4 0.4 334 17 347 255 13.7 0 14.4 13.5 09/02/2005 11:50:00 1.2 0.6 2.6 0.4 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 9 22 27 255 14.4 0.1 14.9 13.8 09/02/2005 12:00:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 1.6 0.7 3 0.4 25 14 358 255 14.1 0.1 14.6 13.8 09/02/2005 12:10:00 2.4 0.8 4.2 0.7 2.4 0.8 4.2 0.4 2.1 0.8 4.2 0.4 31 20 30 255 14.5 0.1 15.2 14.1 09/02/2005 12:20:00 2.2 0.8 4.2 0.4 2.2 0.7 4.2 0.4 1.6 0.7 3 0.4 12 21 2 255 14.8 0.1 15.2 14.6 09/02/2005 12:30:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.6 0.6 3 0.4 353 26 351 255 15 0 15.5 14.9 09/02/2005 12:40:00 1.7 0.8 4.2 0.4 1.6 0.7 3.8 0.4 1.4 0.6 3.4 0.4 10 36 335 255 15.4 0 16 15.2 09/02/2005 12:50:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 9 27 349 255 15.4 0 16 15.2 09/02/2005 13:00:00 2.2 0.8 3.8 0.4 1.9 0.7 3.4 0.4 1.6 0.8 3.4 0.4 334 26 346 255 15.7 0 16.3 15.5 09/02/2005 13:10:00 2.2 0.6 3.8 0.4 2.1 0.6 3.8 0.4 1.7 0.7 3.4 0.4 358 18 26 255 16.1 0 16.3 16 09/02/2005 13:20:00 3.2 0.7 4.9 1.5 3.1 0.7 4.9 1.1 2.5 0.8 4.2 0.4 9 16 3 255 16.2 0.1 16.6 16 09/02/2005 13:30:00 2.9 0.6 4.2 1.1 2.8 0.6 4.2 1.1 2.5 0.7 4.2 1.1 10 18 13 255 16.6 0 17.1 16.3 09/02/2005 13:40:00 2.1 0.5 3 0.7 1.9 0.6 3 0.4 1.5 0.6 2.6 0.4 5 19 31 255 16.8 0.2 17.4 16.8 09/02/2005 13:50:00 2 0.6 3.4 0.7 1.8 0.6 3 0.4 1.3 0.6 2.6 0.4 4 27 346 255 17.4 0.2 18 17.1 09/02/2005 14:00:00 1.8 0.5 3 0.4 1.7 0.6 2.6 0.4 1.4 0.5 2.6 0.4 16 19 23 255 17.5 0.1 18 17.1 09/02/2005 14:10:00 1.9 0.5 3 0.7 1.7 0.5 3 0.4 1.3 0.6 3 0.4 351 39 12 255 17.7 0 18 17.4 09/02/2005 14:20:00 2 0.6 3.4 0.4 1.9 0.6 3 0.4 1.7 0.6 3 0.4 6 30 39 255 17.8 0 18 17.7 09/02/2005 14:30:00 1.4 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 2.6 0.4 18 33 6 255 17.7 0 17.7 17.4 09/02/2005 14:40:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 1.2 0.5 2.3 0.4 336 41 9 255 17.9 0 18 17.7 09/02/2005 14:50:00 1.5 0.7 3.4 0.4 1.3 0.8 3.8 0.4 1.1 0.7 3.4 0.4 4 15 3 255 17.8 0 18 17.7 09/02/2005 15:00:00 0.8 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 48 35 19 255 17.5 0.2 17.7 17.1 09/02/2005 15:10:00 1.1 0.7 2.3 0.4 1 0.6 2.3 0.4 1 0.5 2.3 0.4 4 66 312 255 16.9 0 17.4 16.8 09/02/2005 15:20:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 315 22 317 255 16.4 0.1 17.1 16.3 09/02/2005 15:30:00 1.2 0.7 3 0.4 1.1 0.7 3 0.4 1 0.6 2.6 0.4 341 35 46 255 16.4 0 16.8 16.3 09/02/2005 15:40:00 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 21 17 9 255 16.9 0.3 17.7 16.6 09/02/2005 15:50:00 2.2 1 4.9 0.4 2 1 4.6 0.4 1.6 0.8 3.8 0.4 355 30 357 255 17.8 0 18 17.4 09/02/2005 16:00:00 2.8 0.7 4.9 1.1 2.6 0.8 4.9 0.7 1.8 0.8 4.2 0.4 356 20 15 255 17.7 0.1 18 17.1 09/02/2005 16:10:00 2.1 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.6 0.6 3.4 0.4 40 32 55 255 16.8 0.2 17.1 16.6 09/02/2005 16:20:00 2.5 0.9 4.9 0.4 2.5 1 5.3 0.4 1.9 0.9 4.6 0.4 10 24 6 255 16.1 0 16.6 16 09/02/2005 16:30:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.5 2.2 0.7 3.8 0.7 12 20 18 255 16.1 0 16.3 15.7 09/02/2005 16:40:00 1.8 0.9 3.4 0.4 1.7 0.9 3.8 0.4 1.3 0.9 3.4 0.4 15 28 15 255 15.6 0.1 16 15.2 09/02/2005 16:50:00 1.3 0.7 3.4 0.4 1.2 0.7 3.4 0.4 0.8 0.6 2.6 0.4 0 22 1 255 15 0.1 15.7 14.6 09/02/2005 17:00:00 2.1 0.8 4.2 0.4 2 0.7 4.2 0.4 1.5 0.7 3.4 0.4 357 17 356 255 14.6 0.2 15.2 14.1 09/02/2005 17:10:00 1.7 0.7 3.4 0.4 1.4 0.7 3 0.4 1.1 0.6 3 0.4 342 18 339 255 14.1 0.1 14.6 13.8 09/02/2005 17:20:00 1.9 0.6 3 0.4 1.7 0.7 3.4 0.4 1.1 0.7 3 0.4 350 18 323 255 13.6 0.1 14.4 13.3 09/02/2005 17:30:00 1.9 0.6 3.4 0.7 1.7 0.6 3.4 0.4 1.1 0.6 2.3 0.4 345 14 359 255 13.4 0 13.8 13 09/02/2005 17:40:00 2.1 0.6 3.4 0.4 1.9 0.6 3 0.4 1.1 0.6 2.6 0.4 348 12 15 255 12.9 0.1 13.5 12.7 09/02/2005 17:50:00 1.5 0.3 2.3 0.4 1.2 0.4 2.3 0.4 0.8 0.5 2.3 0.4 319 22 337 255 12.6 0.1 13 12.5 09/02/2005 18:00:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.7 0.9 0.4 1.9 0.4 307 9 300 255 12.4 0 12.7 12.2 09/02/2005 18:10:00 1.9 0.3 3 1.1 1.7 0.4 2.6 0.7 1 0.5 1.9 0.4 307 6 300 255 12.1 0.1 12.7 11.7 09/02/2005 18:20:00 2.2 0.4 3.4 1.5 2.1 0.4 3 1.1 1.2 0.6 2.6 0.4 303 8 294 255 11.7 0 12.2 11.7 09/02/2005 18:30:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.6 0.5 2.6 0.4 300 7 301 255 11.5 0 11.9 11.4 09/02/2005 18:40:00 2.1 0.3 3 1.5 1.9 0.3 2.6 1.1 0.7 0.4 1.9 0.4 312 9 308 255 11.1 0 11.4 11.1 09/02/2005 18:50:00 1.7 0.3 2.6 1.1 1.5 0.3 2.6 0.7 0.5 0.2 1.1 0.4 325 8 318 255 10.9 0 11.1 10.9 09/02/2005 19:00:00 1.6 0.2 2.3 0.7 1.3 0.3 1.9 0.7 0.4 0 0.7 0.4 323 11 327 255 10.9 0 11.1 10.9 09/02/2005 19:10:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 323 6 311 255 10.7 0 10.9 10.6 09/02/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 326 0 255 255 10.5 0 10.6 10.3 09/02/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 255 255 10.2 0 10.3 9.8 09/02/2005 19:40:00 0.9 0.5 1.5 0.4 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 327 0 327 255 9.8 0.1 10.1 9.6 09/02/2005 19:50:00 1.3 0.2 1.5 1.1 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 327 0 327 255 9.6 0 9.8 9.3 09/02/2005 20:00:00 1.5 0.2 1.9 0.7 1.3 0.2 1.9 0.7 0.4 0 0.4 0.4 343 12 327 255 9.4 0 9.6 9.3 09/02/2005 20:10:00 1.2 0.5 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.4 0.4 354 0 354 255 9.2 0 9.3 9 09/02/2005 20:20:00 2 0.5 2.6 0.4 2 0.5 2.6 0.4 0.8 0.5 1.9 0.4 52 13 37 255 9 0 9.3 9 09/02/2005 20:30:00 1.9 0.7 3 0.4 1.9 0.7 3 0.4 1 0.5 2.3 0.4 66 12 57 255 8.8 0.1 9 8.5 09/02/2005 20:40:00 1.4 0.6 2.6 0.4 1.3 0.5 2.6 0.4 0.5 0.3 1.5 0.4 83 12 73 255 8.5 0 8.8 8.5 09/02/2005 20:50:00 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.4 0.1 1.1 0.4 97 13 116 255 8.5 0 8.8 8.3 09/02/2005 21:00:00 1.9 0.4 2.6 0.7 1.8 0.4 3 0.7 0.6 0.4 1.9 0.4 66 11 82 255 8.1 0 8.5 8 09/02/2005 21:10:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.3 0.4 2.3 0.4 64 9 63 255 8.1 0 8.3 8 09/02/2005 21:20:00 2.1 0.4 3 0.7 2 0.4 3 0.7 1.1 0.5 2.3 0.4 67 18 84 255 8 0 8 7.8 09/02/2005 21:30:00 2.3 0.3 3.4 1.5 2.3 0.4 3.4 1.5 1.4 0.4 2.6 0.4 72 10 44 255 7.9 0 8 7.8 09/02/2005 21:40:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 1.5 0.5 2.6 0.4 83 10 85 255 7.6 0 7.8 7.5 09/02/2005 21:50:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.5 1.5 0.5 2.6 0.4 91 9 88 255 7.3 0 7.5 7.3 09/02/2005 22:00:00 2.7 0.5 4.2 1.9 2.6 0.5 4.2 1.5 1.5 0.6 3 0.4 88 10 76 255 7.3 0 7.5 7.3 09/02/2005 22:10:00 3 0.5 4.2 0.7 2.9 0.6 4.2 0.7 1.5 0.5 3 0.4 87 10 88 255 7.3 0 7.5 7.3 09/02/2005 22:20:00 3.1 0.4 4.6 1.9 3.1 0.5 4.6 1.9 1.6 0.5 3 0.4 88 11 75 255 7.3 0 7.3 7.3 09/02/2005 22:30:00 3.3 0.5 4.9 2.3 3.2 0.5 4.9 1.9 1.9 0.5 3.4 0.4 89 9 84 255 7.1 0 7.3 7 09/02/2005 22:40:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 1.9 2 0.6 3.4 0.4 80 9 81 255 6.9 0 7 7 09/02/2005 22:50:00 3.7 0.7 5.3 1.9 3.7 0.7 5.3 1.9 2.1 1 4.9 0.4 84 10 80 255 6.9 0 7 7 09/02/2005 23:00:00 4.1 0.5 5.7 2.6 4 0.6 5.7 2.3 2.7 0.6 4.2 1.1 87 11 84 255 7.3 0.2 7.5 7 09/02/2005 23:10:00 4.5 0.6 6.1 2.6 4.4 0.6 6.1 2.3 3.1 0.6 4.6 1.5 88 9 71 255 8 0.3 8.5 7.5 09/02/2005 23:20:00 4.2 0.8 6.1 1.9 4.1 0.9 5.7 1.5 2.8 0.9 5.3 1.1 90 13 92 255 8.7 0 9 8.5 09/02/2005 23:30:00 4 0.8 5.7 1.9 4 0.7 6.1 2.3 2.7 0.9 4.9 0.7 88 11 94 255 8.7 0 9 8.5 09/02/2005 23:40:00 4.5 0.8 6.5 2.3 4.5 0.8 6.5 2.3 3.1 0.8 5.7 1.1 88 11 95 255 8.5 0 8.8 8.3 09/02/2005 23:50:00 4.2 0.9 6.8 1.9 4.2 0.9 7.2 1.9 2.9 0.9 4.9 0.4 85 11 104 255 8.9 0 9 8.8 09/03/2005 00:00:00 4.3 0.7 6.1 2.3 4.2 0.7 6.1 2.3 3 0.7 5.3 1.5 90 12 101 255 9.2 0.1 9.6 8.8 09/03/2005 00:10:00 3.7 0.6 5.3 1.9 3.7 0.5 5.3 2.3 2.7 0.7 4.6 0.7 97 11 97 255 9.5 0 9.6 9.3 09/03/2005 00:20:00 4.2 0.7 6.1 2.6 4.2 0.6 6.1 2.6 3.3 0.5 4.9 1.5 100 9 108 255 9.4 0 9.6 9.3 09/03/2005 00:30:00 4.3 0.8 5.7 1.1 4.3 0.8 6.5 0.7 3 0.8 4.9 1.1 105 15 106 255 9.3 0 9.6 9.3 09/03/2005 00:40:00 4.3 0.6 6.1 2.3 4.3 0.7 6.5 1.9 3.3 0.7 4.9 1.5 103 11 99 255 9.3 0 9.3 9 09/03/2005 00:50:00 3.8 0.7 5.3 1.1 3.8 0.7 5.3 1.5 2.6 0.7 4.2 0.4 110 15 99 255 9.3 0 9.3 9.3 09/03/2005 01:00:00 3.2 0.9 5.3 0.7 3.1 0.9 5.3 0.7 2.1 0.9 4.2 0.4 120 20 126 255 9.2 0 9.3 9 09/03/2005 01:10:00 3.1 0.6 4.6 1.5 3 0.6 4.6 1.5 2.1 0.7 3.8 0.4 110 18 97 255 8.9 0 9.3 8.8 09/03/2005 01:20:00 3.4 0.8 5.3 0.7 3.3 0.8 5.3 1.1 2.1 0.8 4.2 0.4 109 17 107 255 8.8 0 9 8.8 09/03/2005 01:30:00 3.7 0.8 5.7 1.9 3.6 0.8 5.3 1.9 2.6 0.7 5.3 1.1 121 14 116 255 8.8 0 9 8.8 09/03/2005 01:40:00 3.5 0.7 5.3 1.9 3.5 0.7 5.3 1.5 2.5 0.6 4.2 0.7 121 16 131 255 8.7 0 8.8 8.8 09/03/2005 01:50:00 3 0.7 5.3 1.5 3.1 0.7 4.9 1.5 2.1 0.6 3.8 0.7 122 17 108 255 8.7 0 9 8.8 09/03/2005 02:00:00 3.7 0.7 5.7 1.5 3.7 0.7 5.7 1.5 2.7 0.7 4.6 1.1 122 15 115 255 8.9 0 9 8.8 09/03/2005 02:10:00 3.3 0.8 4.9 0.7 3.2 0.8 4.9 0.7 2.3 0.7 4.2 0.4 120 15 117 255 8.9 0 9 9 09/03/2005 02:20:00 3.6 1 6.1 1.5 3.6 0.9 6.5 1.1 2.6 0.8 4.6 0.4 120 16 113 255 8.9 0 9 9 09/03/2005 02:30:00 4 1 6.1 1.5 3.9 0.9 6.1 1.1 2.7 0.9 5.3 0.7 115 18 119 255 8.9 0 9 9 09/03/2005 02:40:00 4.9 0.9 6.8 2.6 4.8 0.8 6.8 2.6 3.5 0.9 5.7 1.1 109 15 116 255 9 0 9.3 9 09/03/2005 02:50:00 4.8 0.7 6.5 2.6 4.7 0.7 6.8 2.3 3.4 0.7 5.3 1.5 105 12 123 255 9.3 0 9.3 9.3 09/03/2005 03:00:00 4.3 0.7 6.1 2.6 4.3 0.7 6.1 2.3 3.2 0.8 5.7 1.5 106 13 113 255 9.4 0 9.6 9.3 09/03/2005 03:10:00 4.8 0.8 6.5 2.3 4.7 0.8 6.5 1.9 3.4 0.8 5.3 1.5 107 13 101 255 9.4 0 9.6 9.3 09/03/2005 03:20:00 5 0.7 6.5 2.6 5 0.6 6.5 3 3.8 0.8 5.3 1.9 104 12 98 255 9.4 0 9.6 9.3 09/03/2005 03:30:00 4.8 0.7 6.5 3 4.7 0.7 6.1 2.6 3.8 0.8 5.7 1.1 107 13 111 255 9.4 0 9.6 9.3 09/03/2005 03:40:00 4.9 0.8 6.8 3 4.8 0.8 6.8 2.6 3.8 0.8 6.1 1.5 106 12 119 255 9.5 0 9.6 9.3 09/03/2005 03:50:00 4.7 0.8 6.8 3 4.6 0.8 6.8 2.6 3.5 1 6.1 1.5 108 16 106 255 9.5 0 9.6 9.3 09/03/2005 04:00:00 4.6 1 6.8 1.9 4.5 1 6.8 1.9 3.4 0.9 5.7 1.1 112 15 110 255 9.5 0 9.6 9.3 09/03/2005 04:10:00 4.5 0.9 7.2 2.3 4.4 1 7.6 2.3 3.5 0.9 6.1 1.5 117 15 109 255 9.4 0 9.6 9.3 09/03/2005 04:20:00 4.8 1 7.6 2.3 4.7 1 7.6 2.3 3.6 1.1 6.5 0.7 118 15 97 255 9.2 0 9.3 9 09/03/2005 04:30:00 4.5 0.9 6.5 2.3 4.4 0.8 6.8 2.3 3.4 0.8 5.3 1.9 113 13 105 255 9 0 9.3 9 09/03/2005 04:40:00 4.7 0.7 6.5 2.6 4.6 0.7 6.5 2.6 3.7 0.8 5.7 1.5 110 14 104 255 9.1 0 9.3 9 09/03/2005 04:50:00 4.7 0.9 6.8 2.3 4.6 0.9 7.2 2.3 3.8 1 6.1 1.5 100 13 119 255 9.2 0 9.3 9 09/03/2005 05:00:00 4.6 0.8 6.5 2.6 4.4 0.9 6.5 2.3 3.6 0.8 5.7 1.5 106 12 113 255 9.1 0 9.3 9 09/03/2005 05:10:00 3.9 0.9 5.7 1.5 3.9 1 6.1 1.9 3 1.1 5.7 0.4 109 15 108 255 9.1 0 9.3 9 09/03/2005 05:20:00 4.5 0.8 6.5 2.6 4.4 0.8 5.7 2.3 3.5 0.8 5.7 1.5 109 12 106 255 9.2 0 9.3 9 09/03/2005 05:30:00 5 0.7 6.8 3 4.8 0.7 6.5 2.6 3.7 0.9 6.1 1.1 107 12 112 255 9.3 0 9.3 9 09/03/2005 05:40:00 5 0.9 7.2 2.6 4.9 1 7.2 2.3 3.8 0.9 6.5 1.5 109 12 116 255 9.4 0 9.6 9.3 09/03/2005 05:50:00 5.3 1 8.4 3 5.2 1.1 7.6 2.3 4.1 1 6.8 1.5 110 13 126 255 9.4 0 9.6 9.3 09/03/2005 06:00:00 5 1.2 7.6 1.9 4.9 1.2 8 2.3 3.8 1 6.5 1.5 112 18 118 255 9.4 0 9.6 9.3 09/03/2005 06:10:00 4.5 1 7.2 2.3 4.4 1 6.8 2.3 3.4 0.9 6.1 1.5 111 15 92 255 9.4 0 9.6 9.3 09/03/2005 06:20:00 4.9 1 6.8 1.5 4.7 1 6.5 0.7 3.8 0.9 6.5 1.1 110 15 104 255 9.5 0 9.6 9.6 09/03/2005 06:30:00 4.6 0.8 6.5 2.6 4.4 0.8 6.5 2.3 3.6 1 6.1 0.4 114 15 117 255 9.6 0 9.6 9.6 09/03/2005 06:40:00 4.6 1 6.5 1.5 4.5 1 6.8 0.7 3.5 1 6.1 1.5 111 16 115 255 9.6 0 9.8 9.6 09/03/2005 06:50:00 4.2 1 6.8 1.9 4 1 6.8 1.5 3.2 0.9 5.3 1.1 111 15 102 255 9.7 0 9.8 9.6 09/03/2005 07:00:00 3.9 0.9 6.1 1.5 3.7 1 6.1 1.5 3 0.9 5.7 1.1 106 15 117 255 9.8 0 9.8 9.6 09/03/2005 07:10:00 4.1 0.8 6.8 2.3 3.9 0.8 6.5 1.9 3.1 0.8 5.3 1.5 108 15 110 255 10 0 10.1 9.8 09/03/2005 07:20:00 4.1 0.7 5.7 2.3 3.9 0.8 5.7 1.5 3.2 0.8 5.3 0.7 107 14 117 255 10 0 10.3 9.8 09/03/2005 07:30:00 3.7 0.6 5.3 1.9 3.5 0.7 5.3 1.5 3.1 0.7 5.3 1.5 123 15 132 255 10.3 0 10.6 10.1 09/03/2005 07:40:00 3.2 0.9 5.7 1.1 2.9 0.9 5.3 0.7 2.4 0.8 4.6 0.4 119 15 132 255 10.6 0 10.9 10.6 09/03/2005 07:50:00 3.6 0.7 5.3 1.9 3.4 0.7 5.3 1.5 3 0.7 4.9 1.1 139 15 136 255 10.7 0 10.9 10.6 09/03/2005 08:00:00 2.7 1 5.3 0.4 2.5 1 5.3 0.4 2 1 4.6 0.4 135 17 129 255 10.6 0 10.6 10.6 09/03/2005 08:10:00 3 0.8 5.3 1.1 2.8 0.9 4.6 0.4 2.3 0.8 4.6 0.4 131 13 115 255 10.6 0 10.9 10.6 09/03/2005 08:20:00 3.7 0.8 6.1 1.5 3.5 0.8 5.7 1.1 2.8 0.8 4.9 1.1 125 14 119 255 10.8 0 11.1 10.6 09/03/2005 08:30:00 3.2 0.9 5.3 1.1 2.9 1 4.9 0.4 2.4 0.8 4.2 0.7 120 15 119 255 11 0 11.1 10.9 09/03/2005 08:40:00 3.7 0.8 5.3 1.5 3.4 0.8 4.9 0.7 2.9 0.8 4.9 1.1 128 12 127 255 11.1 0 11.1 11.1 09/03/2005 08:50:00 3.2 0.7 4.6 1.5 2.9 0.8 4.6 0.7 2.3 0.9 4.2 0.4 129 14 127 255 11.1 0 11.4 11.1 09/03/2005 09:00:00 3.2 0.8 5.3 1.1 2.9 0.9 5.3 0.7 2.3 0.6 4.2 0.7 127 16 136 255 11.3 0 11.7 11.1 09/03/2005 09:10:00 1.8 1 4.6 0.4 1.2 1.1 4.2 0.4 1.1 0.9 3.8 0.4 116 29 108 255 11.6 0 11.7 11.4 09/03/2005 09:20:00 1.4 0.7 3.4 0.4 0.9 0.7 3.4 0.4 0.7 0.6 2.6 0.4 125 23 116 255 11.7 0 11.9 11.7 09/03/2005 09:30:00 1.2 0.5 2.6 0.4 0.6 0.5 2.3 0.4 0.7 0.5 2.3 0.4 133 22 119 255 11.9 0 12.2 11.7 09/03/2005 09:40:00 1.1 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.7 0.5 2.3 0.4 146 22 115 255 12.3 0 12.2 12.2 09/03/2005 09:50:00 2 0.6 3.4 0.7 1.4 0.7 3 0.4 1.2 0.6 3 0.4 117 16 137 255 12.4 0 12.5 12.2 09/03/2005 10:00:00 2 0.6 3.8 0.4 1.5 0.7 3.4 0.4 1.3 0.6 3 0.4 120 21 114 255 12.7 0 12.7 12.5 09/03/2005 10:10:00 2.3 0.8 4.2 0.4 1.9 0.9 3.8 0.4 1.8 0.8 3.4 0.4 118 18 122 255 12.9 0.1 13.3 12.7 09/03/2005 10:20:00 2.3 1 4.9 0.4 2 1 4.6 0.4 1.8 1 4.2 0.4 115 18 94 255 13.3 0 13.3 13 09/03/2005 10:30:00 1 0.6 2.6 0.4 0.5 0.4 2.3 0.4 0.6 0.4 2.6 0.4 137 41 86 255 13.5 0 13.5 13.3 09/03/2005 10:40:00 1.8 0.4 2.6 0.4 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 109 17 113 255 13.7 0 13.8 13.5 09/03/2005 10:50:00 1.2 0.8 3 0.4 0.9 0.7 2.6 0.4 0.9 0.6 2.6 0.4 101 21 93 255 13.9 0 14.4 13.8 09/03/2005 11:00:00 0.9 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 125 30 186 255 14.4 0.2 15.2 14.1 09/03/2005 11:10:00 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 76 23 80 255 14.9 0 15.5 14.9 09/03/2005 11:20:00 0.5 0.3 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.4 0.4 136 36 90 255 15.1 0 15.5 15.2 09/03/2005 11:30:00 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 81 17 80 255 14.9 0 15.2 14.9 09/03/2005 11:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.3 1.5 0.4 76 11 61 255 14.9 0 15.2 14.9 09/03/2005 11:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 0 55 255 14.9 0 15.2 14.9 09/03/2005 12:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 64 94 143 255 15 0 15.7 15.2 09/03/2005 12:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 124 30 144 255 15 0 15.5 14.9 09/03/2005 12:20:00 1.6 0.7 3 0.4 1.6 0.8 3 0.4 1.6 0.8 3 0.4 166 18 167 255 15 0 15.5 14.9 09/03/2005 12:30:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 140 19 142 255 15.2 0.1 15.7 15.2 09/03/2005 12:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 140 9 134 255 15.5 0 16.3 15.5 09/03/2005 12:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 186 43 141 255 16 0.2 16.6 15.7 09/03/2005 13:00:00 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 195 64 264 255 16.2 0 16.6 16 09/03/2005 13:10:00 1.3 0.6 3 0.4 1.2 0.7 3 0.4 0.9 0.6 3 0.4 237 22 215 255 16.4 0 16.8 16.3 09/03/2005 13:20:00 1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 204 22 211 255 16.6 0 16.8 16.6 09/03/2005 13:30:00 0.8 0.5 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 104 76 62 255 17.1 0.1 17.7 16.8 09/03/2005 13:40:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 264 39 250 255 17.7 0 18 17.1 09/03/2005 13:50:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 235 66 300 255 17.8 0 18.2 17.4 09/03/2005 14:00:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 311 64 306 255 17.5 0 17.7 17.4 09/03/2005 14:10:00 0.9 0.7 3 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.6 0.4 333 35 346 255 17.7 0 17.7 17.4 09/03/2005 14:20:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 0.8 0.6 2.6 0.4 302 24 309 255 17.3 0 17.7 16.8 09/03/2005 14:30:00 1.7 0.9 3.8 0.4 1.5 0.9 3.4 0.4 1.3 0.9 3 0.4 305 32 291 255 16.7 0.1 17.1 16.3 09/03/2005 14:40:00 1 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.5 0.3 1.5 0.4 352 27 356 255 16.4 0 16.6 16.3 09/03/2005 14:50:00 1.2 0.6 3 0.4 0.9 0.5 3 0.4 0.6 0.5 2.3 0.4 10 29 352 255 16.4 0 16.8 16.3 09/03/2005 15:00:00 0.9 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.1 0.4 134 51 163 255 16.1 0 16.6 16.3 09/03/2005 15:10:00 1.3 1 4.9 0.4 1.2 1.1 5.3 0.4 1.1 1.2 4.9 0.4 52 64 89 255 16.2 0.1 16.8 16.3 09/03/2005 15:20:00 1.1 0.8 3.8 0.4 1 0.8 4.2 0.4 1 0.9 4.2 0.4 86 58 67 255 15.9 0 16.6 15.7 09/03/2005 15:30:00 2.2 0.9 4.2 0.4 2.1 0.9 4.2 0.4 1.3 0.9 3.4 0.4 225 30 232 255 15.8 0 16.3 15.7 09/03/2005 15:40:00 1.6 0.8 3 0.4 1.4 0.8 3 0.4 0.9 0.7 2.6 0.4 245 30 201 255 15.7 0 16 15.5 09/03/2005 15:50:00 2.7 1 4.9 0.4 2.5 1 5.3 0.4 1.9 1 4.2 0.4 251 22 256 255 15.3 0.2 15.7 15.2 09/03/2005 16:00:00 1.9 1 3.8 0.4 1.7 1 3.8 0.4 1 0.7 3.4 0.4 220 18 214 255 15.1 0 15.5 15.2 09/03/2005 16:10:00 2.2 0.8 3.8 0.4 2 0.7 3.8 0.4 1.4 0.7 3 0.4 230 18 203 255 15.1 0.1 15.7 15.2 09/03/2005 16:20:00 3.3 0.6 5.3 1.5 3.1 0.7 5.3 1.1 2.1 0.9 3.8 0.4 228 17 236 255 15.1 0.1 15.7 14.9 09/03/2005 16:30:00 2.9 1 5.3 0.4 2.7 1.1 5.3 0.4 2.1 1.2 4.9 0.4 224 17 228 255 14.8 0.2 15.5 14.6 09/03/2005 16:40:00 3.4 0.9 5.3 0.4 3.2 1 5.3 0.4 2.4 0.9 5.3 0.4 224 16 233 255 14.5 0 15.2 14.4 09/03/2005 16:50:00 3 0.8 4.6 1.1 2.9 0.9 4.6 0.7 2 0.9 3.8 0.4 221 15 225 255 14.2 0 14.6 14.4 09/03/2005 17:00:00 2.8 0.7 4.6 1.1 2.7 0.7 4.6 1.1 2 0.8 4.2 0.4 199 14 197 255 14.1 0 14.4 14.1 09/03/2005 17:10:00 2.1 0.9 4.2 0.4 1.9 0.9 3.8 0.4 1.4 0.9 3.8 0.4 195 15 185 255 14 0 14.6 13.8 09/03/2005 17:20:00 3.6 0.6 4.9 2.3 3.4 0.6 4.9 1.9 2.6 0.7 4.6 0.7 203 11 223 255 13.9 0 14.6 13.8 09/03/2005 17:30:00 2.9 0.9 4.9 1.1 2.7 1 4.6 0.7 2 0.9 4.2 0.4 197 13 189 255 13.9 0 14.4 13.8 09/03/2005 17:40:00 2.5 0.6 4.2 1.1 2.5 0.7 4.2 0.7 1.7 1 4.2 0.4 187 17 188 255 13.7 0 14.1 13.5 09/03/2005 17:50:00 1.4 0.7 3 0.4 1.2 0.7 2.6 0.4 0.7 0.6 2.6 0.4 194 17 187 255 13.7 0 14.4 13.5 09/03/2005 18:00:00 1.1 0.5 2.6 0.4 0.7 0.5 1.9 0.4 0.4 0.3 1.5 0.4 187 20 198 255 13.7 0 14.4 13.5 09/03/2005 18:10:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 172 33 199 255 13.6 0.1 14.4 13.5 09/03/2005 18:20:00 1.8 0.8 3.8 0.4 1.5 0.9 3.8 0.4 1.2 0.8 3 0.4 86 61 108 255 13.4 0 14.1 13.3 09/03/2005 18:30:00 1.8 0.7 3.4 0.4 1.7 0.6 3.4 0.4 1 0.5 2.6 0.4 60 38 26 255 13.4 0 13.8 13.3 09/03/2005 18:40:00 1.3 0.7 3.4 0.4 1.1 0.6 3.4 0.4 0.6 0.4 2.6 0.4 11 43 4 255 13.3 0 13.8 13.3 09/03/2005 18:50:00 2.4 1.1 4.9 0.4 2.1 1.2 4.9 0.4 1.5 1 4.2 0.4 25 22 356 255 13.3 0 13.3 13.3 09/03/2005 19:00:00 1.7 0.8 3.8 0.4 1.3 0.8 3.4 0.4 0.8 0.6 3 0.4 37 23 60 255 13.2 0 13.3 13 09/03/2005 19:10:00 2.7 1 4.9 0.7 2.5 1 4.9 0.4 2 0.8 4.6 0.4 39 19 22 255 12.9 0 13 12.7 09/03/2005 19:20:00 3.5 1.2 6.8 0.7 3.4 1.2 6.8 1.1 2.7 1.2 6.1 0.4 22 22 1 255 12.9 0 13 12.7 09/03/2005 19:30:00 5.9 0.9 8.4 3.4 5.8 1 8.4 3 4.4 1.1 7.2 1.9 16 13 18 255 12.7 0 13 12.5 09/03/2005 19:40:00 5.8 1.3 9.5 2.6 5.6 1.3 9.1 2.6 4.4 1.4 8.4 0.7 20 15 39 255 12.8 0 12.7 12.7 09/03/2005 19:50:00 5.1 1.1 8 2.6 5 1.1 7.6 2.6 3.6 1.2 6.5 0.7 15 16 358 255 12.6 0 12.7 12.5 09/03/2005 20:00:00 6.1 1.2 8.8 2.3 6 1.2 8.8 2.6 4.5 1.3 8 1.9 13 14 2 255 12.4 0 12.5 12.2 09/03/2005 20:10:00 5.9 1 9.1 3.4 5.8 1.1 9.1 3 4.2 1.1 7.2 1.5 9 14 18 255 12.4 0 12.5 12.2 09/03/2005 20:20:00 5.3 1.1 8 2.6 5.2 1.1 8.4 2.6 3.6 1.3 7.2 0.7 13 13 1 255 12.3 0 12.5 12.2 09/03/2005 20:30:00 5.3 1.1 8 2.6 5.2 1.2 8 1.9 3.7 1.3 7.2 0.4 12 15 26 255 12.1 0 12.2 11.9 09/03/2005 20:40:00 6.1 1.1 9.5 3.8 6 1.2 9.9 3.4 4.5 1.4 8 1.1 13 12 13 255 12.2 0 12.2 11.9 09/03/2005 20:50:00 5.9 1 8.8 3.4 5.8 1 8.8 3.4 4.1 1.2 8 1.1 10 13 5 255 12.1 0 12.2 11.9 09/03/2005 21:00:00 5.1 1.5 9.5 2.3 5 1.6 9.1 1.9 3.6 1.6 8 0.4 11 17 26 255 12.1 0 12.2 11.9 09/03/2005 21:10:00 6.4 1 9.1 3.4 6.3 0.9 9.1 3.8 5 1.1 7.6 2.3 16 9 29 255 12.1 0 12.2 11.9 09/03/2005 21:20:00 5.3 0.9 8 3 5.2 0.9 8 2.6 4.2 1.2 7.2 1.5 22 11 32 255 12.3 0 12.5 12.2 09/03/2005 21:30:00 5.5 0.7 7.2 3 5.4 0.7 7.6 3 4.4 0.9 6.5 2.3 33 12 35 255 12.6 0 12.7 12.5 09/03/2005 21:40:00 5 0.8 7.2 3.4 4.9 0.8 7.2 3 4.2 0.9 6.1 1.9 28 9 19 255 12.7 0 12.7 12.5 09/03/2005 21:50:00 5.3 0.7 8 3.8 5.1 0.8 7.6 3.8 4.3 0.8 6.5 2.3 33 11 33 255 12.5 0 12.7 12.5 09/03/2005 22:00:00 5.5 0.9 8 3 5.4 1 8 2.6 4.5 1 7.6 2.3 28 11 45 255 12.5 0 12.7 12.5 09/03/2005 22:10:00 6 0.9 8.8 3.4 5.9 1 8.8 3.8 4.8 1.1 8 2.3 29 12 28 255 12.5 0 12.7 12.5 09/03/2005 22:20:00 5.5 0.9 8 3 5.4 0.9 8 2.6 4.4 1.1 7.2 1.9 42 17 21 255 12.6 0 12.7 12.5 09/03/2005 22:30:00 4.2 0.8 6.5 2.3 4.1 0.8 6.1 2.3 3.3 0.8 5.3 1.5 60 12 49 255 12.5 0 12.7 12.2 09/03/2005 22:40:00 4.7 0.8 6.8 3 4.6 0.8 6.8 2.6 3.6 0.8 5.7 1.5 66 13 72 255 12.2 0 12.2 11.9 09/03/2005 22:50:00 3.9 0.8 6.1 1.9 3.7 0.8 6.5 2.3 3 0.7 4.9 1.5 64 13 52 255 12.3 0 12.5 12.2 09/03/2005 23:00:00 5.1 0.9 7.6 3.4 4.9 1 8 3 3.8 1 6.8 1.5 64 15 38 255 11.9 0 12.2 11.9 09/03/2005 23:10:00 4.7 0.9 7.2 1.9 4.5 1 7.2 1.5 3.9 1.1 6.8 1.1 55 13 48 255 12.3 0 12.5 12.2 09/03/2005 23:20:00 4.2 1.1 6.8 1.1 4.1 1.2 6.8 1.5 3.4 1 6.1 1.1 64 14 58 255 12.3 0 12.5 12.2 09/03/2005 23:30:00 4.7 1 7.6 2.3 4.6 1 7.2 1.9 3.8 1 6.5 1.1 62 15 61 255 12.4 0 12.5 12.2 09/03/2005 23:40:00 5.1 1 7.6 2.6 5 1.1 7.6 2.6 4 1 7.2 1.9 53 13 54 255 12.5 0 12.7 12.5 09/03/2005 23:50:00 4.5 0.8 7.2 2.3 4.5 0.9 7.2 2.3 3.5 0.8 5.7 1.5 57 15 54 255 12.3 0 12.5 12.2 09/04/2005 00:00:00 4.5 0.9 7.6 2.3 4.5 1 7.6 2.6 3.6 1 6.5 1.9 58 15 71 255 12.3 0 12.5 12.2 09/04/2005 00:10:00 4.5 1 7.2 1.9 4.4 1 6.8 1.9 3.6 0.8 6.1 1.9 62 15 47 255 12.2 0 12.2 12.2 09/04/2005 00:20:00 5.4 1.2 8.8 2.6 5.3 1.2 8.4 2.6 4.5 1.2 7.2 1.5 65 15 66 255 12.3 0 12.2 12.2 09/04/2005 00:30:00 6.1 1.2 9.9 2.6 6 1.2 9.5 3 4.9 1.1 8.4 1.9 51 13 49 255 12.3 0 12.5 12.2 09/04/2005 00:40:00 5.3 0.9 8 2.6 5.2 1 8.4 2.6 4 1 6.5 1.9 54 13 59 255 12.2 0 12.5 11.9 09/04/2005 00:50:00 5.5 1 7.6 2.6 5.4 1 7.6 2.6 4.2 0.9 6.8 1.5 50 13 37 255 12.1 0 12.2 11.9 09/04/2005 01:00:00 4.9 1.1 7.2 2.3 4.9 1.1 7.6 2.3 3.9 1 6.1 1.5 58 13 59 255 12 0 12.2 11.9 09/04/2005 01:10:00 4.9 1 7.6 3 4.9 1 8 2.3 3.9 1.1 7.2 1.5 65 15 38 255 11.9 0 11.9 11.7 09/04/2005 01:20:00 5 1 7.2 2.6 4.9 1 7.2 2.3 3.7 1.2 6.8 1.5 68 15 77 255 11.7 0 11.9 11.7 09/04/2005 01:30:00 4.4 0.9 7.2 2.3 4.3 0.9 7.2 1.9 3.4 0.9 6.5 1.5 67 14 64 255 11.5 0 11.7 11.4 09/04/2005 01:40:00 4.6 0.9 6.8 1.9 4.5 1 6.8 1.9 3.6 0.9 6.1 1.9 60 13 40 255 11.6 0 11.7 11.4 09/04/2005 01:50:00 4.7 1 7.2 2.3 4.6 1.1 7.6 2.3 3.8 1.1 6.8 0.7 64 15 59 255 11.7 0 11.9 11.7 09/04/2005 02:00:00 4.1 0.8 5.7 2.3 4 0.8 5.7 1.9 3.2 0.8 4.9 1.5 65 13 79 255 11.6 0 11.7 11.4 09/04/2005 02:10:00 4.3 0.8 6.8 2.3 4.2 0.9 6.5 1.9 3.3 1 5.7 1.1 79 13 79 255 11.2 0 11.4 11.1 09/04/2005 02:20:00 4.5 0.6 6.1 2.3 4.4 0.6 5.7 2.3 3.4 0.7 5.3 1.1 77 11 83 255 11.1 0 11.1 11.1 09/04/2005 02:30:00 4.2 0.6 5.7 2.6 4.1 0.7 5.7 1.9 3.4 0.9 4.9 1.1 75 11 68 255 11.1 0 11.1 11.1 09/04/2005 02:40:00 4.6 0.8 6.5 2.6 4.5 0.8 6.8 2.6 3.6 0.9 6.1 1.9 74 12 64 255 11.1 0 11.4 11.1 09/04/2005 02:50:00 4.2 0.8 6.1 2.3 4 0.8 6.1 1.9 3.1 0.8 5.3 1.1 68 11 60 255 11.2 0 11.4 11.1 09/04/2005 03:00:00 4.5 0.8 6.8 2.6 4.4 1 6.8 1.9 3.6 0.8 5.7 1.9 68 12 74 255 11.3 0 11.4 11.4 09/04/2005 03:10:00 4.8 0.9 7.2 3 4.6 1 7.2 2.3 3.9 0.8 5.7 1.9 64 12 51 255 11.3 0 11.4 11.1 09/04/2005 03:20:00 4.2 0.8 6.5 2.6 4.1 0.8 6.5 1.9 3.4 0.8 5.7 1.5 67 13 48 255 11.1 0 11.4 11.1 09/04/2005 03:30:00 5 1 7.2 2.6 4.9 1 7.6 2.6 3.8 1.1 6.8 0.7 68 14 55 255 10.9 0 11.1 10.9 09/04/2005 03:40:00 5.6 1.2 8.8 3 5.6 1.2 8.4 2.6 4.5 1.1 8 1.9 56 15 37 255 11.1 0 11.1 10.9 09/04/2005 03:50:00 5.2 1 8 3 5.2 1.1 8 2.6 4.3 1 6.5 1.9 57 14 48 255 11 0 11.1 10.9 09/04/2005 04:00:00 4.9 0.9 6.8 3 4.9 1 6.8 2.3 3.9 1 6.5 1.5 63 12 52 255 10.9 0 11.1 10.9 09/04/2005 04:10:00 4.5 0.7 6.8 2.6 4.4 0.7 6.5 2.6 3.6 0.8 5.3 1.9 63 11 69 255 10.7 0 10.9 10.6 09/04/2005 04:20:00 4.4 0.8 6.8 2.6 4.4 0.9 6.8 1.9 3.4 0.9 5.7 1.1 67 16 51 255 10.6 0 10.9 10.6 09/04/2005 04:30:00 4.3 0.8 6.8 2.6 4.2 0.9 6.8 2.3 3.6 0.8 6.1 1.1 70 12 65 255 10.6 0 10.6 10.6 09/04/2005 04:40:00 4.8 1 7.6 2.3 4.8 1 8 2.3 4 0.9 6.1 1.9 65 13 69 255 10.6 0 10.6 10.6 09/04/2005 04:50:00 4.5 0.8 7.6 2.6 4.4 0.8 7.2 2.6 3.7 0.8 6.1 1.5 64 12 70 255 10.6 0 10.9 10.6 09/04/2005 05:00:00 4 0.7 5.7 1.9 3.9 0.7 5.7 1.9 3.3 0.7 4.9 1.5 67 15 94 255 10.6 0 10.9 10.6 09/04/2005 05:10:00 4.3 0.9 6.8 2.3 4.3 0.9 7.2 2.3 3.3 0.9 5.7 1.1 79 12 69 255 10.5 0 10.6 10.6 09/04/2005 05:20:00 4.4 0.7 6.1 2.6 4.3 0.7 6.1 2.3 3.4 0.8 5.3 1.5 75 11 81 255 10.5 0 10.6 10.6 09/04/2005 05:30:00 4 0.7 5.7 2.3 3.9 0.7 5.7 1.5 3.2 0.7 5.3 1.1 82 12 80 255 10.5 0 10.6 10.6 09/04/2005 05:40:00 4.1 1 6.1 1.9 4 1.1 6.1 1.1 3.1 1.1 5.7 0.4 86 12 90 255 10.5 0 10.6 10.3 09/04/2005 05:50:00 4.7 0.8 6.5 2.6 4.5 0.8 6.8 2.3 3.6 0.8 5.7 1.5 83 13 95 255 10.5 0 10.6 10.3 09/04/2005 06:00:00 5.1 0.7 6.8 2.6 5 0.7 6.8 2.6 4.1 0.9 6.1 1.9 82 12 90 255 10.5 0 10.6 10.3 09/04/2005 06:10:00 4.8 0.8 6.8 2.6 4.7 0.8 6.5 2.6 3.5 0.9 6.5 1.9 82 12 87 255 10.6 0 10.9 10.6 09/04/2005 06:20:00 4.5 0.8 6.1 2.6 4.4 0.8 6.1 2.6 3.3 0.9 5.3 0.7 82 11 87 255 10.7 0 10.9 10.6 09/04/2005 06:30:00 4.3 0.8 6.5 2.3 4.2 0.8 6.1 1.9 3.2 1 6.1 0.4 81 15 98 255 10.6 0 10.9 10.6 09/04/2005 06:40:00 5.3 0.8 7.2 3.4 5.3 0.7 7.2 3.4 4.4 0.8 6.5 2.3 77 15 95 255 10.7 0 10.9 10.6 09/04/2005 06:50:00 4.9 1 7.2 1.9 4.8 1 6.8 1.1 3.7 1.1 6.8 1.1 78 14 86 255 10.9 0 11.1 10.9 09/04/2005 07:00:00 4.9 0.9 7.2 2.6 4.9 0.9 6.8 2.3 3.9 1 6.5 1.1 85 14 91 255 11.1 0 11.1 10.9 09/04/2005 07:10:00 4.6 0.7 6.5 2.6 4.5 0.7 6.1 1.9 3.6 0.8 5.3 1.5 86 11 105 255 11.1 0 11.4 11.1 09/04/2005 07:20:00 5 0.9 7.6 2.6 4.9 1 8 2.3 3.7 1.1 6.5 0.7 76 16 70 255 11.3 0 11.4 11.1 09/04/2005 07:30:00 4.9 0.8 7.2 3 4.8 0.8 7.6 2.3 4 0.9 6.8 1.1 77 13 90 255 11.5 0 11.7 11.4 09/04/2005 07:40:00 5.1 0.9 8.4 2.6 5.1 1 8.4 2.3 4 1 6.5 1.9 77 12 74 255 11.5 0 11.7 11.4 09/04/2005 07:50:00 4.7 0.9 6.8 2.3 4.7 1 7.2 1.9 3.6 1 6.1 1.5 76 13 78 255 11.5 0 11.7 11.4 09/04/2005 08:00:00 4.6 1 7.6 1.5 4.6 1.1 7.6 1.5 3.7 1 6.1 1.5 67 15 66 255 11.7 0 11.7 11.7 09/04/2005 08:10:00 5 1 7.6 3 5 1 7.2 3 4.1 1 6.5 1.5 71 14 48 255 11.8 0 11.9 11.7 09/04/2005 08:20:00 5.3 1 8 2.3 5.2 1.1 7.6 1.9 4.1 1 6.8 1.9 76 13 67 255 11.9 0 11.9 11.7 09/04/2005 08:30:00 4.9 0.7 6.8 3.4 4.7 0.7 6.5 3 4 0.7 5.7 1.9 84 11 77 255 12 0 12.2 11.9 09/04/2005 08:40:00 5.1 1 8 2.6 5 1.1 8 2.6 4.1 1.1 8 1.9 73 14 84 255 12.3 0.1 12.5 11.9 09/04/2005 08:50:00 5.9 1.2 8.8 3.4 5.8 1.3 9.1 3 4.7 1.2 8 1.9 76 14 62 255 12.7 0 12.7 12.5 09/04/2005 09:00:00 4.8 0.8 7.2 2.6 4.7 0.8 7.2 2.6 4 0.8 7.2 2.3 69 13 86 255 12.8 0 12.7 12.7 09/04/2005 09:10:00 5.5 1.3 8.8 1.9 5.5 1.3 8.8 2.3 4.5 1.3 8 1.5 65 15 58 255 12.8 0 12.7 12.7 09/04/2005 09:20:00 5.6 1.1 9.1 2.6 5.5 1.1 9.1 3 4.4 1.1 8 1.9 69 17 60 255 12.8 0 13 12.7 09/04/2005 09:30:00 6.1 1.5 9.9 2.3 6 1.5 10.3 2.3 5 1.4 8.8 2.3 75 17 58 255 13 0 13 12.7 09/04/2005 09:40:00 5.7 1.3 9.5 2.6 5.6 1.3 9.1 2.6 4.4 1.2 7.6 1.5 79 17 60 255 13.1 0 13.3 13 09/04/2005 09:50:00 5.3 1.5 9.9 1.9 5.2 1.5 9.1 1.1 4.1 1.5 8 1.1 80 17 70 255 13.3 0 13.3 13 09/04/2005 10:00:00 5.9 1.2 8.4 2.6 5.8 1.2 8.8 2.6 4.6 1.4 8 1.1 83 14 68 255 13.3 0 13.5 13.3 09/04/2005 10:10:00 5.7 1.3 8.4 1.9 5.6 1.3 8.4 1.9 4.6 1.2 7.6 1.9 81 15 75 255 13.4 0 13.5 13.3 09/04/2005 10:20:00 4.9 1 7.6 2.6 4.8 1 7.6 2.6 3.8 1 6.8 1.1 79 17 80 255 13.6 0 13.8 13.5 09/04/2005 10:30:00 5.5 1.2 8.8 1.9 5.5 1.3 8.8 1.5 4.5 1.2 7.2 1.5 76 17 82 255 13.8 0 13.8 13.5 09/04/2005 10:40:00 5.6 1.3 8.8 2.3 5.5 1.3 8.4 1.9 4.7 1.3 8.4 1.9 79 17 65 255 13.9 0 14.1 13.8 09/04/2005 10:50:00 4.8 1.3 8 2.3 4.7 1.3 8 1.9 3.8 1.3 7.2 1.1 90 15 111 255 13.8 0 13.8 13.5 09/04/2005 11:00:00 5.2 1.2 9.1 1.9 5.1 1.2 8.8 1.1 4.2 1.3 8 1.5 82 16 94 255 13.8 0 13.8 13.5 09/04/2005 11:10:00 5.8 1.3 8.8 2.3 5.7 1.3 9.1 3 4.8 1.4 8.4 1.9 73 21 94 255 13.9 0 14.1 13.8 09/04/2005 11:20:00 4.9 1.1 8 2.6 4.8 1.1 7.2 2.3 3.9 1.1 6.8 1.5 81 16 90 255 13.9 0 14.1 13.8 09/04/2005 11:30:00 6 1.4 9.1 2.6 5.9 1.4 9.1 2.6 4.8 1.4 8 1.5 74 17 64 255 13.9 0 13.8 13.8 09/04/2005 11:40:00 4.9 1.1 8.4 2.3 4.9 1.2 8 2.3 4.2 1 7.2 2.3 79 15 90 255 13.7 0 13.8 13.5 09/04/2005 11:50:00 5.1 1.3 8 1.5 4.9 1.3 8 1.5 4.1 1.2 6.8 1.9 76 17 54 255 13.5 0 13.5 13.3 09/04/2005 12:00:00 4.8 1 8.4 1.9 4.6 1 8.8 2.3 3.9 1 6.8 1.5 71 16 74 255 13.5 0 13.5 13.3 09/04/2005 12:10:00 5.3 1 7.6 2.3 5.2 1 7.6 2.6 4.4 1.1 7.2 1.1 71 15 67 255 13.3 0 13.5 13.3 09/04/2005 12:20:00 4.6 1 9.5 2.3 4.5 1.1 9.5 2.6 3.8 1.1 6.8 1.1 70 14 78 255 13.3 0 13.3 13.3 09/04/2005 12:30:00 4.3 0.9 6.8 1.9 4.2 1 7.2 1.1 3.4 0.9 6.1 1.1 72 17 64 255 13.3 0 13.3 13.3 09/04/2005 12:40:00 4.5 1.1 6.8 1.9 4.4 1.1 7.2 1.9 3.7 1 6.5 1.5 76 16 93 255 13.3 0 13.3 13.3 09/04/2005 12:50:00 5 1.1 7.6 2.3 4.9 1.2 7.6 2.3 4 1.2 6.8 0.7 72 19 68 255 13.3 0 13.3 13.3 09/04/2005 13:00:00 4.2 0.9 7.2 1.5 4 1 6.5 1.1 3.3 1 6.1 0.7 63 21 90 255 13.3 0 13.3 13.3 09/04/2005 13:10:00 4.1 0.9 7.2 1.9 4 0.9 6.8 1.9 3.2 1 5.7 0.4 77 18 45 255 13.3 0 13.3 13 09/04/2005 13:20:00 3.8 1 6.5 1.9 3.6 1 6.1 1.5 3 1 6.1 0.7 75 17 79 255 13.2 0 13.3 13 09/04/2005 13:30:00 4.2 1 6.8 1.1 4.1 1.1 6.8 1.1 3.4 1 5.7 0.4 70 18 79 255 13.2 0 13.3 13 09/04/2005 13:40:00 4.2 1 7.2 2.3 4.2 1 6.8 2.3 3.5 1 6.8 1.5 71 16 58 255 13.3 0 13.3 13.3 09/04/2005 13:50:00 4.8 1.2 8 1.9 4.6 1.3 8 1.5 4 1.1 6.8 1.5 65 19 83 255 13.3 0 13.3 13.3 09/04/2005 14:00:00 4.2 1 7.2 1.5 4 1.1 6.8 1.1 3.4 1 5.7 0.7 75 18 72 255 13.1 0 13.3 13 09/04/2005 14:10:00 5.7 1.5 9.9 2.6 5.6 1.5 9.9 2.6 4.4 1.4 8.8 1.5 71 16 56 255 13.1 0 13.3 13 09/04/2005 14:20:00 5.8 1.3 9.1 2.3 5.7 1.3 8.8 1.9 4.7 1.5 8.4 0.7 74 17 68 255 13.1 0 13.3 13 09/04/2005 14:30:00 5.8 1.1 9.5 3 5.7 1.2 9.5 2.6 5 1.1 8 1.9 65 15 73 255 13.3 0 13.3 13 09/04/2005 14:40:00 5.4 1.3 9.1 2.3 5.4 1.3 9.1 2.6 4.7 1.2 8 1.9 74 14 68 255 13.3 0 13.5 13.3 09/04/2005 14:50:00 4.8 0.9 6.8 3 4.7 0.9 6.8 3 3.9 1 6.8 1.9 74 13 45 255 13.3 0 13.3 13 09/04/2005 15:00:00 4.5 1 6.8 2.3 4.4 1 6.8 1.9 3.6 0.9 6.1 1.5 74 15 48 255 13.1 0 13.3 13 09/04/2005 15:10:00 4.3 1.1 7.2 1.9 4.2 1.2 7.2 1.5 3.4 1.1 6.8 1.1 72 17 67 255 13.1 0 13.3 12.7 09/04/2005 15:20:00 5.1 1 8 2.6 5 1.2 8.8 2.3 4.4 1.2 7.2 1.5 69 15 55 255 13.1 0 13.3 13 09/04/2005 15:30:00 5.8 1.2 8.8 2.6 5.7 1.3 8.8 2.3 4.6 1.3 7.6 1.1 58 16 53 255 13.1 0 13.3 13 09/04/2005 15:40:00 4.8 0.8 7.2 2.6 4.8 0.9 6.8 2.6 3.7 0.9 6.8 1.5 72 17 85 255 13.1 0 13.3 12.7 09/04/2005 15:50:00 5.1 0.9 8 3 5 0.9 7.6 2.3 4 1 6.5 1.1 67 17 83 255 12.9 0 13 12.7 09/04/2005 16:00:00 4.9 1.1 7.6 2.6 4.7 1.2 7.6 2.3 3.8 1 6.5 1.9 60 16 46 255 12.9 0 13 12.7 09/04/2005 16:10:00 4.3 0.8 6.5 2.3 4.2 0.9 6.5 1.9 3.6 0.9 5.7 1.1 49 12 71 255 12.8 0 13 12.7 09/04/2005 16:20:00 3.4 0.5 4.6 1.5 3.2 0.6 4.2 1.1 2.8 0.7 4.2 1.1 42 12 39 255 12.7 0 12.7 12.5 09/04/2005 16:30:00 3.2 0.5 4.6 1.5 3 0.6 4.2 0.7 2.5 0.6 4.2 0.4 47 12 45 255 12.5 0 12.7 12.5 09/04/2005 16:40:00 2.8 0.7 4.6 1.1 2.5 0.8 4.6 0.4 2.1 0.8 4.2 0.4 56 14 46 255 12.5 0 12.5 12.5 09/04/2005 16:50:00 3.1 0.6 4.9 1.9 2.9 0.7 4.9 1.5 2.5 0.6 4.2 1.1 41 12 43 255 12.4 0 12.5 12.5 09/04/2005 17:00:00 3.1 0.8 5.7 1.5 2.8 0.8 5.3 1.1 2.5 0.7 4.9 1.1 43 11 40 255 12.4 0 12.5 12.5 09/04/2005 17:10:00 3.2 0.5 4.6 1.9 2.9 0.6 4.2 1.5 2.6 0.7 4.6 0.4 34 16 41 255 12.4 0 12.5 12.2 09/04/2005 17:20:00 2.9 0.6 4.6 1.5 2.6 0.7 4.2 0.7 2.1 0.6 3.4 0.4 27 14 22 255 12.3 0 12.5 12.2 09/04/2005 17:30:00 2.7 0.4 3.8 1.1 2.4 0.5 3.4 0.7 2 0.6 3.4 0.4 21 9 13 255 12.3 0 12.2 12.2 09/04/2005 17:40:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 0.7 1.9 0.6 3.4 0.4 18 9 33 255 12.1 0 12.2 11.9 09/04/2005 17:50:00 1.9 0.4 3 0.7 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 21 12 19 255 12 0 12.2 11.9 09/04/2005 18:00:00 1.4 0.3 2.3 0.7 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 28 7 18 255 11.9 0 11.9 11.7 09/04/2005 18:10:00 1.2 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 17 8 25 255 11.7 0 11.9 11.7 09/04/2005 18:20:00 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.8 0.3 1.5 0.4 31 8 19 255 11.7 0 11.7 11.7 09/04/2005 18:30:00 1.1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 32 0 32 255 11.7 0 11.7 11.7 09/04/2005 18:40:00 1.2 0.3 1.9 0.7 0.5 0.3 1.5 0.4 0.8 0.3 1.5 0.4 30 5 32 255 11.5 0 11.7 11.4 09/04/2005 18:50:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 46 13 86 255 11.3 0 11.7 11.1 09/04/2005 19:00:00 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 1.1 0.5 2.3 0.4 46 13 31 255 11.1 0 11.1 11.1 09/04/2005 19:10:00 1 0.5 2.6 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 34 22 33 255 10.9 0 11.1 10.9 09/04/2005 19:20:00 1.4 0.6 3 0.4 0.9 0.6 2.3 0.4 0.8 0.5 2.3 0.4 56 13 37 255 10.7 0.1 11.1 10.6 09/04/2005 19:30:00 2.5 0.7 4.9 1.1 2.2 0.8 4.9 0.4 1.9 0.6 3.4 0.4 47 12 58 255 10.7 0 10.9 10.6 09/04/2005 19:40:00 2.6 0.5 4.2 1.1 2.3 0.6 4.2 0.7 2 0.5 3.4 0.7 54 15 84 255 11 0 11.1 10.9 09/04/2005 19:50:00 3 0.7 4.6 1.1 2.8 0.8 4.2 0.7 2.3 0.6 3.8 0.7 53 13 44 255 11.2 0 11.4 11.1 09/04/2005 20:00:00 3.2 0.8 6.1 1.5 3 0.9 5.7 1.1 2.6 0.8 5.3 0.7 53 16 66 255 11.4 0 11.4 11.4 09/04/2005 20:10:00 3.5 0.8 6.5 1.5 3.2 0.9 6.5 1.5 2.8 0.8 4.9 1.1 53 15 48 255 11.5 0 11.7 11.4 09/04/2005 20:20:00 2.9 0.6 4.2 1.1 2.6 0.8 4.6 0.4 2.2 0.6 3.8 0.7 48 15 70 255 11.5 0 11.7 11.4 09/04/2005 20:30:00 2.8 0.6 4.6 1.1 2.5 0.7 4.6 0.4 2.1 0.6 3.8 0.7 48 17 44 255 11.4 0 11.7 11.4 09/04/2005 20:40:00 3.3 0.9 6.1 1.5 3.1 1 5.7 1.1 2.6 0.8 4.9 0.4 55 15 40 255 11.5 0 11.7 11.4 09/04/2005 20:50:00 4.3 0.8 6.1 1.9 4.2 0.9 6.1 1.5 3.4 0.9 5.7 1.1 52 15 14 255 11.6 0 11.7 11.4 09/04/2005 21:00:00 4.1 0.8 6.1 1.9 3.9 0.9 6.1 1.5 3.3 0.8 5.3 1.9 55 14 62 255 11.7 0 11.7 11.7 09/04/2005 21:10:00 3.4 0.7 4.9 1.5 3.1 0.7 4.9 1.1 2.7 0.7 4.2 1.1 55 13 77 255 11.5 0 11.7 11.4 09/04/2005 21:20:00 2.8 0.8 5.3 1.1 2.4 1 4.9 0.4 2.1 0.8 4.9 0.4 29 21 64 255 11.3 0 11.4 11.1 09/04/2005 21:30:00 2 0.5 3 0.7 1.5 0.7 3 0.4 1.3 0.6 2.6 0.4 20 10 14 255 10.9 0.2 11.1 10.6 09/04/2005 21:40:00 2.1 0.5 3.4 1.1 1.6 0.7 3 0.4 1.4 0.6 2.6 0.4 43 9 30 255 10.6 0 10.6 10.6 09/04/2005 21:50:00 2.1 0.5 3 0.7 1.6 0.6 3 0.4 1.4 0.7 2.6 0.4 25 11 37 255 10.6 0 10.6 10.6 09/04/2005 22:00:00 0.7 0.5 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 27 3 33 255 10.2 0 10.6 10.1 09/04/2005 22:10:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 39 13 56 255 10 0 10.1 9.8 09/04/2005 22:20:00 1.3 0.3 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 36 13 43 255 9.8 0 9.8 9.6 09/04/2005 22:30:00 1.9 0.3 2.6 1.1 1.6 0.4 2.3 0.7 1.2 0.4 2.3 0.4 46 9 54 255 9.6 0 9.8 9.6 09/04/2005 22:40:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 49 11 62 255 9.5 0 9.6 9.6 09/04/2005 22:50:00 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 29 5 33 255 9.5 0 9.6 9.6 09/04/2005 23:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 34 2 33 255 9.4 0 9.6 9.3 09/04/2005 23:10:00 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.7 0.3 1.9 0.4 47 11 51 255 9.4 0 9.6 9.3 09/04/2005 23:20:00 1.1 0.3 1.9 0.4 0.7 0.3 1.9 0.4 0.5 0.3 1.5 0.4 38 2 34 255 9.3 0 9.3 9.3 09/04/2005 23:30:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 48 12 39 255 9.2 0 9.3 9 09/04/2005 23:40:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 62 0 62 255 9.2 0 9.3 9 09/04/2005 23:50:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 78 17 62 255 9.2 0 9.3 9.3 09/05/2005 00:00:00 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 99 2 101 255 9.2 0 9.3 9 09/05/2005 00:10:00 1.4 0.2 1.9 1.1 1.1 0.3 1.9 0.4 0.6 0.2 1.5 0.4 101 7 101 255 9.2 0 9.3 9 09/05/2005 00:20:00 1.5 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.8 0.3 1.9 0.4 109 11 111 255 9.2 0 9.3 9 09/05/2005 00:30:00 1.8 0.4 2.6 0.7 1.2 0.5 1.9 0.4 1 0.4 1.9 0.4 110 8 104 255 9.2 0 9.3 9 09/05/2005 00:40:00 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 102 5 105 255 9.2 0 9.3 9 09/05/2005 00:50:00 1.4 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 115 10 121 255 9.2 0 9.3 9 09/05/2005 01:00:00 1.7 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1.3 0.3 1.9 0.4 123 6 116 255 9.3 0 9.3 9.3 09/05/2005 01:10:00 1.7 0.4 2.6 0.7 1.1 0.5 2.6 0.4 1.1 0.4 2.3 0.4 126 12 115 255 9.4 0 9.6 9.3 09/05/2005 01:20:00 2.2 0.5 3.4 0.7 1.8 0.6 3 0.4 1.2 0.5 2.3 0.4 111 11 104 255 9.4 0 9.6 9.3 09/05/2005 01:30:00 2.3 0.4 3.4 1.5 1.7 0.6 3 0.4 1.2 0.6 2.6 0.4 103 9 91 255 9.5 0 9.6 9.3 09/05/2005 01:40:00 2.6 0.5 3.4 1.1 2.1 0.7 3 0.4 1.5 0.5 2.6 0.4 105 8 115 255 9.6 0 9.6 9.6 09/05/2005 01:50:00 2 0.5 3.4 0.7 1.2 0.7 2.6 0.4 1.1 0.5 2.3 0.4 101 7 99 255 9.6 0 9.6 9.6 09/05/2005 02:00:00 1.4 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 90 7 100 255 9.6 0 9.8 9.6 09/05/2005 02:10:00 0.8 0.4 1.5 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 76 1 80 255 9.6 0 9.6 9.6 09/05/2005 02:20:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 0 76 255 9.4 0 9.6 9.3 09/05/2005 02:30:00 0.8 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 75 0 75 255 9.3 0 9.6 9.3 09/05/2005 02:40:00 1.1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 61 7 71 255 9.2 0 9.3 9 09/05/2005 02:50:00 1.1 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 41 35 71 255 9.2 0 9.3 9 09/05/2005 03:00:00 1.2 0.6 2.6 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 323 14 324 255 9.3 0 9.3 9.3 09/05/2005 03:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 355 28 309 255 9.1 0 9.3 9 09/05/2005 03:20:00 0.9 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.3 2.3 0.4 99 33 100 255 9.2 0 9.3 9 09/05/2005 03:30:00 0.6 0.5 2.3 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 96 15 64 255 9.2 0 9.3 9 09/05/2005 03:40:00 2.5 1 5.3 0.4 2.3 1.1 5.3 0.4 1.7 1 4.2 0.4 90 21 94 255 9.4 0 9.6 9 09/05/2005 03:50:00 4.2 0.7 6.1 2.6 4.1 0.7 6.1 2.6 3.3 0.8 5.3 0.7 101 10 102 255 9.8 0 10.1 9.6 09/05/2005 04:00:00 3.9 0.8 6.5 2.3 3.8 0.8 6.1 1.9 2.9 0.8 5.3 0.4 102 14 88 255 10.2 0 10.3 10.1 09/05/2005 04:10:00 2.2 0.9 4.9 0.4 1.7 1 4.6 0.4 1.5 0.7 4.2 0.4 84 22 119 255 10.3 0 10.3 10.3 09/05/2005 04:20:00 3.6 0.9 5.7 1.5 3.4 1 5.7 1.1 2.6 0.9 4.9 0.4 104 15 122 255 10.3 0 10.6 10.3 09/05/2005 04:30:00 3.5 0.8 6.1 1.9 3.2 0.9 5.7 1.5 2.7 0.8 5.7 1.1 111 16 101 255 10.5 0 10.6 10.3 09/05/2005 04:40:00 4 0.9 6.1 1.9 3.7 1 5.7 0.4 3.1 1 5.3 0.7 116 15 115 255 10.4 0 10.6 10.3 09/05/2005 04:50:00 3.8 0.9 6.5 1.9 3.4 1 6.1 0.7 2.8 0.8 5.3 0.7 112 16 90 255 10.3 0 10.6 10.3 09/05/2005 05:00:00 3.8 0.8 6.1 1.5 3.5 0.9 5.7 1.1 2.9 0.9 5.3 0.7 112 14 99 255 10.2 0 10.6 10.3 09/05/2005 05:10:00 3.8 0.9 5.7 1.1 3.5 1 6.1 0.7 2.8 0.8 4.9 1.1 117 15 122 255 10.2 0 10.3 10.1 09/05/2005 05:20:00 3.3 0.8 5.3 1.5 2.9 0.9 5.3 0.7 2.5 0.7 4.6 1.1 113 17 129 255 10.1 0 10.3 10.1 09/05/2005 05:30:00 3.5 0.8 5.3 1.5 3 0.9 4.9 0.7 2.6 0.8 4.6 1.1 118 16 115 255 10 0 10.1 9.8 09/05/2005 05:40:00 3.5 0.9 5.3 1.5 3.1 0.9 4.9 0.7 2.4 0.8 4.6 0.4 117 18 111 255 10 0 10.1 9.8 09/05/2005 05:50:00 2.5 1 4.9 0.4 1.9 1.1 4.6 0.4 1.7 0.8 4.6 0.4 114 19 119 255 9.9 0 10.1 9.8 09/05/2005 06:00:00 1.7 0.6 3.4 0.4 1.2 0.7 3 0.4 1.3 0.7 3 0.4 86 27 121 255 9.8 0 10.3 9.8 09/05/2005 06:10:00 2.3 0.7 4.6 0.7 1.9 0.9 4.2 0.4 1.5 0.8 3.4 0.4 95 17 112 255 9.9 0 10.1 9.8 09/05/2005 06:20:00 2 0.7 4.2 0.7 1.4 0.8 4.2 0.4 1.3 0.7 3.4 0.4 91 19 91 255 10 0 10.1 9.8 09/05/2005 06:30:00 2.9 0.7 4.9 1.5 2.6 0.8 4.6 0.7 1.9 0.8 4.2 0.4 102 15 106 255 10 0 10.1 9.8 09/05/2005 06:40:00 1.9 0.7 4.2 0.4 1.5 0.8 4.2 0.4 1.4 0.7 3 0.4 81 20 83 255 10 0 10.1 9.8 09/05/2005 06:50:00 1.5 0.7 3.8 0.4 0.9 0.6 3 0.4 0.8 0.5 2.6 0.4 77 45 124 255 10 0 10.1 9.8 09/05/2005 07:00:00 1.3 0.6 3 0.4 0.9 0.7 3 0.4 0.8 0.5 2.6 0.4 64 36 43 255 9.8 0 10.1 9.8 09/05/2005 07:10:00 3.1 1 6.1 0.7 2.8 1.1 5.3 0.4 2.4 1.2 6.1 0.4 108 19 117 255 10 0.1 10.3 9.8 09/05/2005 07:20:00 3.6 0.8 6.1 1.5 3.4 0.9 5.7 1.1 2.7 0.9 4.9 0.4 105 17 116 255 10.3 0 10.6 10.3 09/05/2005 07:30:00 4.7 0.8 6.8 2.6 4.5 0.9 6.5 2.3 3.8 0.9 6.1 1.5 110 15 145 255 10.4 0 10.6 10.3 09/05/2005 07:40:00 4.8 0.8 6.8 2.6 4.6 0.9 6.8 2.6 3.9 0.8 6.5 1.9 111 13 89 255 10.5 0 10.6 10.3 09/05/2005 07:50:00 4.4 1 6.5 1.5 4.2 1 6.5 0.7 3.6 0.8 5.7 1.5 114 13 102 255 10.4 0 10.6 10.3 09/05/2005 08:00:00 4.3 0.7 6.1 2.3 4 0.8 5.7 1.9 3.3 0.7 5.3 1.5 111 15 110 255 10.5 0 10.6 10.3 09/05/2005 08:10:00 4 0.8 6.1 1.9 3.7 1 6.1 0.7 3 0.8 5.3 0.7 115 14 103 255 10.6 0 10.6 10.6 09/05/2005 08:20:00 3.9 0.8 5.7 1.9 3.6 0.9 5.7 1.1 3.1 0.8 5.3 1.5 114 15 105 255 10.7 0 10.9 10.6 09/05/2005 08:30:00 3.9 0.8 5.7 1.5 3.7 0.9 5.3 0.7 2.9 0.8 4.9 0.7 116 15 116 255 10.9 0 11.1 10.9 09/05/2005 08:40:00 4 0.8 6.1 1.9 3.7 0.9 5.3 1.5 3.1 0.8 4.9 1.5 115 15 104 255 11 0 11.1 10.9 09/05/2005 08:50:00 3.9 0.9 6.5 1.9 3.6 1 6.1 1.5 3.1 1 5.7 1.1 114 17 127 255 11 0 11.1 10.9 09/05/2005 09:00:00 2 1 4.6 0.4 1.4 1.1 4.2 0.4 1.3 1 3.8 0.4 72 35 91 255 11.1 0 11.1 11.1 09/05/2005 09:10:00 1.7 0.7 3.4 0.4 1 0.7 3.4 0.4 1.2 0.6 3 0.4 90 24 98 255 11.1 0 11.4 11.1 09/05/2005 09:20:00 2.5 0.7 4.2 0.7 2 0.9 4.2 0.4 1.8 0.8 3.4 0.4 101 21 101 255 11.1 0 11.4 11.1 09/05/2005 09:30:00 1.2 0.5 2.6 0.4 0.5 0.4 2.6 0.4 0.7 0.4 1.9 0.4 7 39 85 255 11.1 0 11.1 11.1 09/05/2005 09:40:00 1 0.5 2.3 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 346 9 351 255 11.2 0 11.4 11.1 09/05/2005 09:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 3 5 255 11.4 0 11.7 11.4 09/05/2005 10:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 337 22 7 255 11.5 0 11.7 11.4 09/05/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 0 255 255 11.6 0 11.7 11.4 09/05/2005 10:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 26 14 255 11.7 0 11.9 11.7 09/05/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 42 33 83 255 11.9 0 11.9 11.7 09/05/2005 10:40:00 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 30 15 36 255 12.1 0 12.2 11.9 09/05/2005 10:50:00 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 22 8 6 255 12.3 0 12.5 12.2 09/05/2005 11:00:00 0.9 0.4 1.9 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 34 20 9 255 12.4 0 12.5 12.2 09/05/2005 11:10:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 12 6 25 255 12.4 0 12.5 12.5 09/05/2005 11:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 40 6 26 255 12.5 0 12.7 12.5 09/05/2005 11:30:00 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.9 0.4 71 12 87 255 12.7 0 12.7 12.7 09/05/2005 11:40:00 1.1 0.5 2.3 0.4 0.6 0.4 1.5 0.4 0.9 0.5 1.9 0.4 73 18 88 255 13 0 13 12.7 09/05/2005 11:50:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 44 21 58 255 13.1 0 13 13 09/05/2005 12:00:00 1 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 4 17 4 255 12.9 0 13 12.7 09/05/2005 12:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 0 352 255 13.1 0 13 13 09/05/2005 12:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 43 49 77 255 13.1 0 13 13 09/05/2005 12:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 63 33 25 255 13.1 0 13.3 13 09/05/2005 12:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 25 0 26 255 13.1 0 13.3 13 09/05/2005 12:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 9 14 255 13.3 0 13.3 13 09/05/2005 13:00:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 21 10 30 255 13.3 0 13.3 13.3 09/05/2005 13:10:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 57 17 61 255 13.5 0 13.5 13.3 09/05/2005 13:20:00 1.1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 61 16 71 255 13.5 0 13.5 13.5 09/05/2005 13:30:00 1.8 0.7 3 0.4 1.6 0.8 3 0.4 1.3 0.7 2.6 0.4 73 13 69 255 13.9 0.1 14.4 13.5 09/05/2005 13:40:00 1.5 0.5 3 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 50 24 55 255 14.4 0 14.6 14.4 09/05/2005 13:50:00 1.5 0.7 3.4 0.4 1.3 0.7 3 0.4 1.1 0.7 3 0.4 47 16 37 255 14.5 0 14.9 14.4 09/05/2005 14:00:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 55 12 75 255 14.6 0 15.2 14.6 09/05/2005 14:10:00 2.2 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.6 0.8 3.4 0.4 63 15 77 255 14.7 0 15.5 14.6 09/05/2005 14:20:00 2.9 0.8 4.9 1.5 2.8 0.9 4.6 0.4 2.4 0.9 4.9 0.4 62 13 56 255 15 0 15.5 14.9 09/05/2005 14:30:00 3.4 0.8 5.3 1.9 3.2 0.9 5.7 1.5 2.5 1 4.9 0.4 53 19 39 255 15 0 15.5 15.2 09/05/2005 14:40:00 3.1 0.7 5.3 1.5 2.9 0.8 4.9 1.1 2.4 0.8 3.8 0.7 56 13 68 255 15 0 15.5 14.9 09/05/2005 14:50:00 3.4 1.1 6.5 1.1 3.3 1.2 6.5 0.4 2.8 1.2 6.1 0.4 54 16 47 255 15 0 15.5 14.9 09/05/2005 15:00:00 4 1.1 6.5 1.5 3.9 1.2 6.5 0.7 3.2 1.1 6.1 1.1 50 16 32 255 15 0 15.5 14.9 09/05/2005 15:10:00 3.2 0.8 5.3 1.1 3.1 0.9 5.7 0.7 2.5 0.8 4.9 0.4 62 18 58 255 14.8 0 15.5 14.9 09/05/2005 15:20:00 2.9 1 5.3 1.1 2.6 1 5.7 0.4 2.2 1 4.9 0.4 65 22 77 255 14.8 0 15.2 14.6 09/05/2005 15:30:00 2.2 0.5 3.8 0.7 1.9 0.7 3.8 0.4 1.7 0.5 3.4 0.4 93 15 87 255 14.8 0 15.7 14.6 09/05/2005 15:40:00 4 1 7.6 2.3 3.8 1.1 8 1.5 3.4 1 6.5 1.1 59 22 37 255 15.2 0 15.7 15.2 09/05/2005 15:50:00 4.1 1.2 7.6 1.5 3.9 1.3 7.2 0.4 3.3 1.2 6.8 0.4 63 22 44 255 15.2 0 15.7 15.2 09/05/2005 16:00:00 4.2 1 6.8 1.5 4 1.1 6.8 0.7 3.5 1.1 6.5 0.4 66 15 61 255 15 0 15.5 14.9 09/05/2005 16:10:00 4.9 1.2 8.4 2.6 4.7 1.2 8 1.9 3.9 1.3 7.2 0.7 54 17 54 255 14.8 0 15.2 14.6 09/05/2005 16:20:00 3.4 0.7 6.5 1.5 3.2 0.8 6.5 1.1 2.7 0.8 5.3 0.7 61 17 32 255 14.7 0.1 15.2 14.6 09/05/2005 16:30:00 3.8 1 6.8 1.5 3.7 1.1 6.8 1.1 3 1.1 6.5 0.7 64 17 33 255 14.8 0 15.5 14.6 09/05/2005 16:40:00 5.1 1.3 8.4 2.6 5 1.4 8.8 1.9 4.2 1.4 8 1.5 54 13 45 255 15.2 0.1 16 15.2 09/05/2005 16:50:00 4.7 1.1 7.6 1.9 4.6 1.2 7.6 1.5 3.9 1.1 6.8 1.5 55 15 58 255 15.5 0 16 15.5 09/05/2005 17:00:00 5.4 0.9 8.4 3 5.2 1 8.4 2.3 4.5 0.8 7.2 2.3 46 15 44 255 15.3 0 16 15.2 09/05/2005 17:10:00 5.8 1 8.4 2.6 5.7 1 8 2.6 4.6 1 7.2 1.9 54 15 40 255 15 0 15.7 14.9 09/05/2005 17:20:00 5.5 1 8 2.6 5.4 1.1 8 2.6 4.3 1.2 7.6 1.9 51 16 44 255 14.8 0 15.5 14.9 09/05/2005 17:30:00 6.4 1.1 9.5 3.8 6.3 1.2 9.1 3 5.2 1.1 8 2.3 44 12 46 255 14.6 0 15.2 14.6 09/05/2005 17:40:00 5 0.9 7.2 2.6 4.8 0.9 7.6 2.6 4.1 0.9 6.5 1.5 43 13 42 255 14.6 0 14.9 14.6 09/05/2005 17:50:00 3.9 1.1 7.2 1.9 3.8 1.1 6.8 1.9 3.3 1.2 6.5 0.7 56 18 19 255 14.6 0 14.6 14.6 09/05/2005 18:00:00 3.6 0.8 5.3 1.9 3.5 0.9 5.3 1.5 2.8 1 5.3 0.4 70 16 66 255 14.5 0 14.6 14.4 09/05/2005 18:10:00 4.1 0.8 6.1 1.9 4 0.9 6.1 1.5 3.3 0.8 5.7 0.4 63 17 74 255 14.4 0 14.6 14.4 09/05/2005 18:20:00 4.3 1 7.2 2.3 4.2 1.1 7.6 1.9 3.6 1.1 6.8 1.5 44 15 2 255 14.2 0 14.4 14.4 09/05/2005 18:30:00 4.9 1 6.8 2.3 4.8 1 6.8 1.9 3.8 1 6.5 1.1 66 16 77 255 14.4 0 14.6 14.4 09/05/2005 18:40:00 4.5 1 7.2 2.3 4.3 1 6.8 2.3 3.5 0.9 6.5 1.5 72 15 101 255 14.4 0 14.6 14.4 09/05/2005 18:50:00 4.1 0.9 6.8 1.9 3.9 0.9 6.5 1.5 3.3 1 5.7 1.1 75 16 86 255 14.3 0 14.6 14.4 09/05/2005 19:00:00 4 0.9 6.5 1.9 3.9 1 6.5 1.9 3.3 0.9 5.7 1.5 61 13 59 255 14.2 0 14.4 14.4 09/05/2005 19:10:00 4.5 0.7 6.1 2.3 4.4 0.7 6.5 2.3 3.8 0.9 5.3 1.5 68 15 17 255 14.1 0 14.4 13.8 09/05/2005 19:20:00 4.9 1.1 8 2.3 4.8 1.2 8 1.9 3.8 1.2 6.8 0.4 31 19 11 255 13.8 0 13.8 13.5 09/05/2005 19:30:00 5.5 0.8 8.4 3.4 5.3 0.8 8 3.4 4.5 0.9 6.8 2.3 27 12 24 255 13.7 0 13.8 13.5 09/05/2005 19:40:00 4.3 0.8 6.8 2.3 4.1 0.9 7.2 1.9 3.4 0.8 5.7 1.5 44 12 22 255 13.7 0 13.8 13.5 09/05/2005 19:50:00 4.3 1 8 2.3 4.1 1.1 7.6 1.9 3.4 1 6.5 1.5 47 15 35 255 13.6 0 13.5 13.5 09/05/2005 20:00:00 4 0.6 5.3 2.6 3.9 0.6 5.3 2.3 3.2 0.7 5.3 1.5 63 12 53 255 13.5 0 13.5 13.3 09/05/2005 20:10:00 3.3 0.7 5.7 2.3 3.2 0.8 6.1 1.5 2.6 0.7 5.3 1.1 61 12 51 255 13.3 0 13.5 13.3 09/05/2005 20:20:00 3.3 0.9 6.1 1.5 3 1 6.1 1.1 2.6 0.9 5.3 0.4 50 22 45 255 13.3 0 13.5 13 09/05/2005 20:30:00 4.4 1 7.2 1.9 4.2 1.1 7.2 0.7 3.5 0.9 6.5 1.5 73 18 39 255 13.3 0 13.5 13.3 09/05/2005 20:40:00 4.2 0.8 6.8 1.9 4.1 0.9 6.8 1.9 3.5 0.8 5.7 1.5 66 16 55 255 13.5 0 13.8 13.3 09/05/2005 20:50:00 3.9 1 6.1 1.5 3.8 1 6.1 1.1 3 1 5.3 1.1 66 14 86 255 13.7 0 13.8 13.5 09/05/2005 21:00:00 4.2 1 6.1 1.9 4.1 1.1 6.1 1.5 3.3 1 6.1 1.1 58 16 58 255 13.7 0 13.8 13.3 09/05/2005 21:10:00 2.7 0.6 4.9 0.7 2.4 0.8 4.2 0.4 1.9 0.5 3.4 0.4 69 13 66 255 13.1 0.2 13.3 12.7 09/05/2005 21:20:00 4 1.1 8 1.5 3.7 1.1 8.4 0.7 3.1 1 6.8 1.1 43 17 22 255 12.7 0 12.7 12.7 09/05/2005 21:30:00 4.8 1 7.6 2.3 4.7 1 7.6 2.3 3.8 1.1 6.8 1.5 47 22 44 255 13.1 0.1 13.3 12.7 09/05/2005 21:40:00 4.2 0.7 5.7 2.3 4 0.8 5.7 2.3 3.3 0.8 5.7 1.5 76 15 62 255 13.3 0 13.3 13 09/05/2005 21:50:00 4.3 0.8 6.5 1.9 4.1 0.8 6.5 1.9 3.1 1 5.3 0.7 77 14 56 255 12.9 0.1 13 12.7 09/05/2005 22:00:00 4.3 0.8 6.5 2.3 4.1 0.9 6.5 2.3 3.5 1 6.5 1.5 72 13 80 255 12.9 0 13 12.7 09/05/2005 22:10:00 3.2 0.7 4.9 1.5 3 0.7 4.9 1.5 2.5 0.7 4.6 1.1 83 15 83 255 13.1 0 13.3 13 09/05/2005 22:20:00 2.9 0.7 4.6 1.5 2.7 0.8 4.2 0.7 2.4 0.7 4.2 1.1 81 16 63 255 12.8 0 13 12.7 09/05/2005 22:30:00 3.9 0.7 5.7 2.3 3.8 0.7 5.7 2.3 3.3 0.8 5.3 1.5 99 12 102 255 12.7 0 12.7 12.5 09/05/2005 22:40:00 4 0.7 6.5 2.3 3.9 0.8 5.7 1.5 3.2 0.8 4.9 0.7 79 12 35 255 12.7 0 12.7 12.5 09/05/2005 22:50:00 3.8 0.6 5.7 2.3 3.6 0.7 5.3 1.9 2.9 0.7 4.9 1.1 87 13 90 255 12.8 0 12.7 12.7 09/05/2005 23:00:00 3.6 0.6 4.9 1.5 3.4 0.7 4.9 1.5 2.8 0.6 4.6 0.7 84 14 93 255 12.8 0 12.7 12.7 09/05/2005 23:10:00 3.3 0.8 5.7 1.5 3.3 0.9 5.3 1.1 2.4 0.8 5.3 0.7 77 20 46 255 12.7 0 13 12.7 09/05/2005 23:20:00 2.1 1 5.3 0.7 1.8 1.1 4.6 0.4 1.9 0.9 4.6 0.4 58 21 70 255 13.3 0 13.3 13 09/05/2005 23:30:00 2.3 0.8 4.6 0.7 2 1 4.2 0.4 1.6 0.8 3.4 0.4 65 19 30 255 13 0.2 13.3 12.7 09/05/2005 23:40:00 1.2 0.5 3 0.4 0.9 0.6 2.6 0.4 0.6 0.4 1.9 0.4 83 29 100 255 12.2 0.2 12.7 11.9 09/05/2005 23:50:00 1.8 0.6 3.4 0.4 1.3 0.7 3 0.4 1.2 0.6 2.6 0.4 90 26 93 255 11.9 0.1 11.9 11.7 09/06/2005 00:00:00 2.4 0.8 3.8 0.7 2.2 0.9 4.2 0.4 1.8 0.7 3.4 0.4 98 21 100 255 11.6 0 11.7 11.4 09/06/2005 00:10:00 3.3 0.6 4.9 1.9 3.2 0.7 4.9 1.9 2.5 0.6 4.2 1.1 93 9 94 255 11.6 0 11.7 11.4 09/06/2005 00:20:00 3.8 0.7 5.7 1.9 3.7 0.7 6.1 1.9 2.9 0.7 4.9 1.1 91 11 84 255 11.8 0 12.2 11.7 09/06/2005 00:30:00 3.9 0.6 5.7 2.3 3.8 0.6 5.7 1.9 2.9 0.7 4.9 1.1 89 11 83 255 12.1 0 12.2 11.9 09/06/2005 00:40:00 3.9 0.7 5.7 1.5 3.8 0.7 5.3 1.9 3.1 0.6 4.9 1.1 104 12 91 255 12.1 0 12.2 11.9 09/06/2005 00:50:00 3.9 0.7 5.3 2.6 3.8 0.7 5.7 2.3 3.1 0.7 4.9 1.5 93 12 93 255 12.3 0 12.2 12.2 09/06/2005 01:00:00 4.1 0.8 6.1 1.9 4 0.8 6.1 1.9 3.2 0.8 5.3 1.1 83 10 70 255 12.4 0 12.5 12.2 09/06/2005 01:10:00 4.2 0.8 6.5 2.3 4.2 0.8 6.1 2.3 3.4 0.8 5.7 1.5 77 10 90 255 12.6 0 12.7 12.5 09/06/2005 01:20:00 4.3 0.7 5.7 2.3 4.2 0.7 6.1 1.9 3.2 0.8 5.3 0.4 81 12 81 255 12.7 0 12.7 12.7 09/06/2005 01:30:00 4.3 0.6 6.1 3 4.2 0.7 6.1 2.3 3.2 0.8 5.3 1.1 78 10 88 255 12.5 0 12.7 12.5 09/06/2005 01:40:00 4.5 0.7 6.5 3 4.3 0.7 6.5 2.6 3.4 0.8 5.7 1.5 68 11 62 255 12.4 0 12.5 12.5 09/06/2005 01:50:00 4.4 0.7 6.1 2.6 4.3 0.7 6.1 2.6 3.3 0.8 5.7 1.5 72 11 84 255 12.4 0 12.5 12.2 09/06/2005 02:00:00 4.1 0.7 5.7 1.9 4 0.8 5.7 1.9 3.2 0.8 5.3 1.1 57 15 58 255 12.3 0 12.5 12.2 09/06/2005 02:10:00 3.3 0.5 4.2 1.5 3.1 0.5 4.6 1.5 2.6 0.6 4.2 1.5 49 11 51 255 12.4 0 12.5 12.2 09/06/2005 02:20:00 2.5 0.6 3.8 1.5 2.4 0.7 3.8 0.7 2 0.7 3.4 0.4 38 8 42 255 12.1 0 12.2 11.9 09/06/2005 02:30:00 1.9 0.9 4.2 0.4 1.6 1 4.2 0.4 1 0.7 3 0.4 56 30 97 255 11.7 0 11.9 11.4 09/06/2005 02:40:00 3.6 0.8 5.3 1.9 3.5 0.8 5.3 1.5 2.6 0.7 4.2 0.7 73 14 70 255 11.2 0 11.4 11.1 09/06/2005 02:50:00 1.4 0.6 3.8 0.4 0.9 0.8 3.8 0.4 0.8 0.5 3 0.4 12 26 52 255 11.4 0 11.7 11.1 09/06/2005 03:00:00 1.7 0.5 3 0.4 1.2 0.6 2.6 0.4 1 0.4 2.3 0.4 46 17 57 255 11.1 0 11.4 11.1 09/06/2005 03:10:00 3.7 0.7 5.7 2.3 3.6 0.8 5.3 1.5 2.6 0.8 4.9 0.7 80 11 78 255 11.1 0 11.1 10.9 09/06/2005 03:20:00 2.9 1 5.3 1.1 2.7 1 5.3 0.7 2 0.8 3.8 0.4 46 28 68 255 11.3 0 11.7 11.1 09/06/2005 03:30:00 1.6 0.4 2.6 0.7 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 14 11 28 255 11.2 0 11.4 11.1 09/06/2005 03:40:00 2.4 0.8 4.2 0.7 2.1 0.9 4.2 0.4 1.5 0.7 3.4 0.4 71 19 90 255 10.9 0.1 11.1 10.9 09/06/2005 03:50:00 3.6 0.5 4.6 2.3 3.4 0.5 4.6 2.6 2.6 0.5 3.8 1.5 86 8 88 255 10.8 0 10.9 10.9 09/06/2005 04:00:00 3.3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 2.4 0.6 3.8 1.1 85 9 88 255 11.1 0.1 11.4 10.9 09/06/2005 04:10:00 2.9 0.7 4.9 1.1 2.6 0.8 4.9 0.4 2.3 0.7 3.8 0.7 73 15 62 255 11.6 0 11.9 11.4 09/06/2005 04:20:00 2.6 0.6 4.2 1.5 2.3 0.6 4.2 1.1 1.8 0.8 3.8 0.4 70 17 83 255 11.7 0 11.9 11.7 09/06/2005 04:30:00 2.9 0.5 4.2 1.5 2.7 0.6 4.2 0.7 2.1 0.7 3.8 0.7 79 11 78 255 11.5 0 11.7 11.4 09/06/2005 04:40:00 3.2 0.6 4.9 1.5 3.1 0.7 4.9 1.5 2.5 0.6 4.2 1.1 67 13 49 255 11.4 0 11.7 11.4 09/06/2005 04:50:00 3.5 0.6 4.9 1.9 3.3 0.7 5.3 1.5 2.6 0.7 4.6 0.7 62 12 57 255 11.6 0 11.7 11.4 09/06/2005 05:00:00 3.2 0.7 4.6 1.5 2.9 0.8 4.9 0.7 2.5 0.7 4.6 0.7 56 14 58 255 11.7 0 11.7 11.7 09/06/2005 05:10:00 3.4 0.7 4.9 1.1 3.2 0.8 4.9 0.7 2.6 0.6 4.2 1.1 62 13 40 255 11.7 0 11.7 11.7 09/06/2005 05:20:00 4 0.7 5.7 2.3 3.9 0.8 5.7 1.5 3.2 0.7 4.9 1.1 76 12 69 255 11.6 0 11.7 11.7 09/06/2005 05:30:00 4.1 0.8 6.1 1.9 3.9 0.9 6.1 1.5 3.1 1 5.7 0.4 72 14 61 255 11.7 0 11.7 11.7 09/06/2005 05:40:00 4.6 1 6.8 2.3 4.5 1.1 7.2 1.9 3.7 1.1 6.8 1.1 71 15 53 255 11.7 0 11.9 11.7 09/06/2005 05:50:00 4.4 0.9 6.8 2.3 4.4 0.9 6.8 1.5 3.5 0.9 5.3 1.5 75 13 69 255 11.7 0 11.9 11.7 09/06/2005 06:00:00 4.1 1.1 7.6 1.9 3.9 1.1 6.8 1.9 3.2 1.1 6.8 0.7 75 16 87 255 11.7 0 11.9 11.7 09/06/2005 06:10:00 3.8 1 6.5 1.5 3.6 1 6.8 1.5 3 1 5.7 1.1 74 16 72 255 11.9 0 11.9 11.9 09/06/2005 06:20:00 3.2 0.8 5.3 1.5 3 0.8 4.9 0.7 2.3 0.8 4.2 0.4 86 17 88 255 11.7 0 11.9 11.7 09/06/2005 06:30:00 3.9 0.9 6.1 0.7 3.7 1 5.7 0.4 3 1 5.3 0.4 83 17 83 255 11.5 0 11.7 11.4 09/06/2005 06:40:00 4.5 0.8 6.5 1.9 4.4 0.8 6.1 1.1 3.6 0.8 5.3 1.5 89 13 73 255 11.5 0 11.7 11.4 09/06/2005 06:50:00 4.3 0.8 6.5 1.5 4.2 0.9 6.5 1.5 3.4 0.8 6.1 1.1 87 16 71 255 11.5 0 11.7 11.4 09/06/2005 07:00:00 5 1.1 8 2.3 4.9 1.2 8.4 2.3 3.9 1.2 7.6 1.1 81 16 100 255 11.5 0 11.7 11.4 09/06/2005 07:10:00 4.5 0.9 7.6 2.6 4.4 0.9 7.2 2.6 3.8 0.9 6.5 0.7 83 16 76 255 11.6 0 11.7 11.7 09/06/2005 07:20:00 4.8 1 7.6 2.3 4.8 1 7.2 1.9 3.9 1 6.8 1.9 84 15 74 255 11.5 0 11.7 11.4 09/06/2005 07:30:00 4.3 0.8 6.5 2.3 4.1 0.9 6.1 1.9 3.3 0.8 4.9 1.1 84 13 68 255 11.5 0 11.7 11.4 09/06/2005 07:40:00 4.4 0.7 6.5 3 4.3 0.6 6.1 2.6 3.5 0.8 5.7 1.1 95 12 104 255 11.5 0 11.7 11.4 09/06/2005 07:50:00 3.6 0.8 5.7 1.5 3.4 0.9 6.1 1.1 2.8 1 5.7 0.7 90 11 105 255 11.7 0 11.7 11.7 09/06/2005 08:00:00 3 0.7 4.9 1.5 2.7 0.7 4.6 1.1 2.1 0.7 3.8 0.4 86 15 81 255 11.7 0 11.9 11.7 09/06/2005 08:10:00 3.4 0.8 6.1 1.1 3.2 0.9 5.7 1.1 2.6 0.8 4.9 0.4 77 16 43 255 11.7 0 11.7 11.7 09/06/2005 08:20:00 4.1 0.7 7.2 2.3 4 0.8 7.2 2.3 3.2 0.7 5.3 1.5 70 13 64 255 11.9 0 12.2 11.7 09/06/2005 08:30:00 3.8 0.8 6.1 1.9 3.7 0.8 5.7 1.5 3 0.8 5.3 1.1 73 15 77 255 12.2 0 12.2 11.9 09/06/2005 08:40:00 4.6 1 7.2 1.9 4.5 1 7.2 1.9 3.7 1.1 6.1 1.1 76 13 66 255 12.3 0 12.5 12.2 09/06/2005 08:50:00 4.4 0.8 6.5 2.3 4.3 0.9 6.8 2.3 3.7 0.8 5.7 1.9 63 13 55 255 12.4 0 12.5 12.2 09/06/2005 09:00:00 5 0.9 7.2 2.3 5 0.9 7.2 2.6 4 1 6.5 1.9 69 13 80 255 12.6 0 12.7 12.5 09/06/2005 09:10:00 4.9 1.1 8 2.3 4.8 1.1 8 2.3 3.9 1.1 6.5 1.1 67 13 52 255 12.7 0 12.7 12.7 09/06/2005 09:20:00 5.2 1 8 3 5.1 1.1 8 1.9 4.4 1.1 7.6 2.3 63 13 58 255 12.8 0 12.7 12.7 09/06/2005 09:30:00 5.1 0.9 7.2 2.6 5 1 6.8 2.6 4.2 1 6.8 1.9 66 12 56 255 12.8 0 12.7 12.7 09/06/2005 09:40:00 5.3 1.1 8 1.9 5.3 1.2 8.4 1.5 4.2 1 7.2 1.9 59 15 85 255 12.7 0 12.7 12.5 09/06/2005 09:50:00 4.3 0.7 6.5 2.3 4.2 0.8 6.8 2.3 3.2 0.8 6.5 1.1 61 14 52 255 12.5 0 12.7 12.2 09/06/2005 10:00:00 3.8 0.7 6.1 1.9 3.6 0.8 6.1 1.9 3 0.8 5.7 1.1 71 11 66 255 11.9 0.2 12.2 11.7 09/06/2005 10:10:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.9 2.5 0.7 4.6 1.1 59 13 52 255 11.3 0.1 11.7 11.1 09/06/2005 10:20:00 4.4 0.9 6.5 2.3 4.3 0.9 6.5 2.3 3.3 0.8 5.3 1.5 53 13 35 255 11.1 0 11.4 11.1 09/06/2005 10:30:00 4.3 1.1 7.2 2.3 4.2 1.1 7.2 1.5 3.7 1.1 6.1 1.1 48 17 28 255 11.1 0 11.4 11.1 09/06/2005 10:40:00 3.9 0.8 6.5 2.3 3.8 0.8 6.5 2.3 2.9 1 6.5 1.1 24 15 40 255 11.1 0 11.1 11.1 09/06/2005 10:50:00 4.6 0.8 7.6 2.3 4.5 0.8 7.6 1.9 3.7 0.9 6.5 1.9 35 12 25 255 11.2 0 11.4 11.1 09/06/2005 11:00:00 3.6 0.7 5.3 1.5 3.5 0.7 5.3 1.5 2.8 0.8 4.9 0.7 27 12 3 255 11.7 0 11.9 11.4 09/06/2005 11:10:00 3.4 0.6 5.3 1.9 3.2 0.7 5.3 1.9 2.5 0.8 4.6 0.7 15 13 27 255 12 0 12.2 11.9 09/06/2005 11:20:00 3.3 0.7 5.3 1.5 3.2 0.8 5.3 1.5 2.7 0.8 4.9 1.1 25 11 32 255 12.2 0 12.2 12.2 09/06/2005 11:30:00 3 0.5 4.2 1.5 2.9 0.5 4.6 1.1 2.5 0.6 4.6 0.4 30 15 23 255 12.5 0 12.7 12.2 09/06/2005 11:40:00 3.9 0.8 5.7 1.9 3.7 0.8 5.7 1.1 3.1 0.9 4.9 1.1 48 17 32 255 12.8 0 12.7 12.5 09/06/2005 11:50:00 3.1 0.9 5.7 0.4 3 0.9 4.9 0.4 2.6 0.7 4.6 0.4 68 20 69 255 12.8 0 12.7 12.7 09/06/2005 12:00:00 4.1 0.8 6.1 1.9 3.9 0.8 6.1 1.5 3.2 0.8 5.7 1.1 52 14 76 255 12.5 0.1 12.7 12.2 09/06/2005 12:10:00 4 0.8 6.1 2.3 3.8 0.9 6.1 1.9 3.3 1 5.7 1.1 48 14 58 255 12.2 0 12.5 11.9 09/06/2005 12:20:00 3.9 1 6.5 1.9 3.8 1.1 6.5 1.5 3.2 1.1 6.1 0.7 36 15 62 255 11.9 0.1 12.2 11.7 09/06/2005 12:30:00 4.6 1 6.8 1.9 4.5 1 7.2 1.9 3.7 1 6.8 1.5 56 15 64 255 11.7 0 11.7 11.4 09/06/2005 12:40:00 4.5 1 6.8 2.6 4.3 1 6.8 1.9 3.7 1.1 6.8 1.1 52 15 49 255 11.5 0 11.7 11.4 09/06/2005 12:50:00 3.9 0.8 6.1 1.9 3.8 0.9 6.1 1.1 3.1 0.8 5.3 1.1 47 17 37 255 11.5 0 11.7 11.4 09/06/2005 13:00:00 4.3 0.8 6.5 1.9 4.2 0.9 6.8 1.5 3.3 1 5.7 1.1 54 15 42 255 11.5 0 11.7 11.4 09/06/2005 13:10:00 3.9 0.8 6.1 1.5 3.8 0.8 6.5 0.7 2.9 1 4.9 0.4 67 13 64 255 11.5 0 11.7 11.4 09/06/2005 13:20:00 3.2 0.8 4.9 1.5 3 0.8 4.9 1.1 2.6 0.7 5.3 0.4 56 19 52 255 11.6 0 11.7 11.7 09/06/2005 13:30:00 1.6 0.8 3.4 0.4 1.3 0.9 3.4 0.4 1.1 0.7 3 0.4 62 17 40 255 11.7 0 11.7 11.7 09/06/2005 13:40:00 1 0.6 3 0.4 0.7 0.5 3 0.4 0.6 0.5 2.6 0.4 85 21 102 255 11.7 0 11.9 11.7 09/06/2005 13:50:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 89 22 59 255 11.7 0 11.9 11.7 09/06/2005 14:00:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 83 47 56 255 11.9 0 12.2 11.7 09/06/2005 14:10:00 1.1 0.8 3.8 0.4 1 0.7 3 0.4 0.8 0.6 3 0.4 44 36 67 255 12.1 0 12.2 11.9 09/06/2005 14:20:00 2.8 0.9 4.6 0.4 2.6 0.9 4.6 0.4 2.1 0.7 4.6 0.4 288 13 281 255 11.9 0 12.2 11.7 09/06/2005 14:30:00 2.8 0.7 4.6 0.7 2.4 0.8 4.6 0.4 1.8 0.7 3.8 0.4 275 17 278 255 11.7 0 11.9 11.7 09/06/2005 14:40:00 1.4 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.3 0.8 2.6 0.4 218 58 160 255 11.5 0 11.7 11.4 09/06/2005 14:50:00 3.1 0.5 4.2 1.5 2.8 0.6 4.2 1.1 2.5 0.6 3.8 1.1 130 17 140 255 11.2 0 11.4 11.1 09/06/2005 15:00:00 2.9 0.6 4.6 1.5 2.8 0.6 4.2 1.1 2 0.6 3.8 0.4 92 21 146 255 11.1 0 11.4 11.1 09/06/2005 15:10:00 2.7 0.6 4.2 1.1 2.6 0.7 4.6 0.7 2 0.7 3.8 0.4 62 13 69 255 11.3 0 11.4 11.1 09/06/2005 15:20:00 1.4 0.7 3.4 0.4 1 0.8 3.4 0.4 0.7 0.6 3 0.4 47 41 56 255 11.6 0 11.7 11.4 09/06/2005 15:30:00 2.2 0.5 3.4 1.1 1.9 0.5 3 0.4 1.6 0.6 3 0.4 298 11 298 255 11.7 0 11.7 11.7 09/06/2005 15:40:00 2.1 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.1 0.6 3 0.4 254 22 252 255 11.7 0 11.7 11.7 09/06/2005 15:50:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 200 53 247 255 11.7 0 11.7 11.7 09/06/2005 16:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 174 30 248 255 11.7 0 11.9 11.7 09/06/2005 16:10:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 204 39 241 255 11.8 0 11.9 11.7 09/06/2005 16:20:00 1.6 0.5 3 0.4 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 192 20 198 255 11.9 0 11.9 11.9 09/06/2005 16:30:00 1.3 1 4.9 0.4 1 1 4.9 0.4 0.6 0.5 2.6 0.4 231 33 241 255 12 0 12.2 11.9 09/06/2005 16:40:00 1.6 0.9 4.2 0.4 1.3 1 4.2 0.4 0.9 0.7 3 0.4 270 36 252 255 12 0 12.2 11.9 09/06/2005 16:50:00 2.8 1.5 7.2 0.4 2.6 1.6 6.8 0.4 2.1 1.4 5.7 0.4 268 27 265 255 11.9 0 12.2 11.9 09/06/2005 17:00:00 1.8 1 4.2 0.4 1.5 1 4.2 0.4 1.2 1 3.8 0.4 266 22 304 255 11.9 0 11.9 11.9 09/06/2005 17:10:00 3 1.1 5.7 0.4 2.7 1.2 5.3 0.4 2.1 1.1 5.3 0.4 271 23 255 255 11.9 0 11.9 11.9 09/06/2005 17:20:00 2.6 0.9 5.3 0.7 2.3 1 5.3 0.4 1.6 1 4.9 0.4 262 21 264 255 11.9 0 11.9 11.7 09/06/2005 17:30:00 4.4 1.6 8.8 1.1 4.3 1.7 9.5 0.7 3 1.5 6.8 0.4 254 21 242 255 11.9 0 11.9 11.9 09/06/2005 17:40:00 3.4 1.4 7.6 0.4 3.2 1.5 7.6 0.4 2.4 1.5 6.5 0.4 259 20 268 255 12 0 11.9 11.9 09/06/2005 17:50:00 2.8 1 5.3 0.7 2.6 1 5.7 0.4 1.8 0.9 4.2 0.4 240 19 260 255 12 0 12.2 11.9 09/06/2005 18:00:00 2.4 0.7 4.9 0.7 2.3 0.8 4.9 0.7 1.4 0.9 4.9 0.4 237 17 217 255 12 0 11.9 11.9 09/06/2005 18:10:00 2.2 0.7 4.6 0.4 2 0.9 4.6 0.4 1.3 0.8 4.2 0.4 228 20 252 255 11.9 0 11.9 11.7 09/06/2005 18:20:00 2 0.5 3 0.4 1.5 0.6 3 0.4 0.9 0.6 2.6 0.4 220 13 220 255 11.7 0 11.9 11.7 09/06/2005 18:30:00 1.8 0.5 3.4 0.7 1.3 0.6 3 0.4 0.8 0.5 2.6 0.4 221 14 230 255 11.7 0 11.7 11.4 09/06/2005 18:40:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 214 21 221 255 11.4 0 11.7 11.4 09/06/2005 18:50:00 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 0.9 0.6 2.3 0.4 181 13 196 255 11.2 0 11.4 11.1 09/06/2005 19:00:00 1.4 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 175 9 180 255 11.1 0 11.1 10.9 09/06/2005 19:10:00 0.6 0.4 1.9 0.4 0.4 0.3 1.5 0.4 0.4 0.3 1.9 0.4 169 12 173 255 10.9 0 11.1 10.9 09/06/2005 19:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 170 7 174 255 10.7 0 10.9 10.6 09/06/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 255 255 10.6 0 10.6 10.6 09/06/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 53 255 255 10.6 0 10.6 10.6 09/06/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 6 255 255 10.6 0 10.6 10.6 09/06/2005 20:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 1 21 255 10.5 0 10.6 10.6 09/06/2005 20:10:00 0.8 0.5 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 47 32 90 255 10.5 0 10.6 10.6 09/06/2005 20:20:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 123 10 108 255 10.5 0 10.6 10.6 09/06/2005 20:30:00 1.2 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 118 11 127 255 10.5 0 10.6 10.6 09/06/2005 20:40:00 1.2 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 47 18 65 255 10.5 0 10.6 10.3 09/06/2005 20:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 38 0 38 255 10.3 0 10.6 10.3 09/06/2005 21:00:00 1 0.6 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 40 2 43 255 10.4 0 10.6 10.3 09/06/2005 21:10:00 1.5 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.5 0.4 2.3 0.4 52 11 52 255 10.3 0 10.6 10.3 09/06/2005 21:20:00 1.7 0.4 3 0.7 1.4 0.5 2.6 0.4 0.6 0.4 1.9 0.4 79 13 94 255 10.2 0 10.3 10.3 09/06/2005 21:30:00 1.7 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.6 0.3 1.5 0.4 94 11 102 255 10.2 0 10.3 10.1 09/06/2005 21:40:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.1 1 0.4 1.9 0.4 103 7 108 255 10 0 10.3 9.8 09/06/2005 21:50:00 1.7 0.3 2.6 0.7 1.5 0.4 2.3 0.4 0.6 0.3 1.5 0.4 100 8 105 255 9.9 0 10.1 9.8 09/06/2005 22:00:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.5 0.4 89 23 112 255 9.8 0 9.8 9.8 09/06/2005 22:10:00 2 0.5 3 0.7 1.8 0.6 2.6 0.4 1 0.6 2.3 0.4 97 11 106 255 9.7 0 9.8 9.6 09/06/2005 22:20:00 1.8 0.3 2.6 0.7 1.4 0.4 2.3 0.4 0.6 0.3 1.5 0.4 99 12 90 255 9.5 0 9.6 9.3 09/06/2005 22:30:00 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 90 12 114 255 9.4 0 9.6 9.3 09/06/2005 22:40:00 1.2 0.7 2.6 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.1 0.4 74 11 62 255 9.2 0 9.3 9 09/06/2005 22:50:00 2.1 0.3 2.6 1.1 1.7 0.4 2.3 0.7 0.7 0.4 1.5 0.4 80 6 72 255 9.1 0 9.3 9 09/06/2005 23:00:00 2.3 0.5 3.8 1.5 1.9 0.6 3.4 0.7 0.7 0.5 1.9 0.4 90 10 68 255 9.1 0 9.3 9 09/06/2005 23:10:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.5 1.7 0.5 3 0.4 68 12 70 255 9.4 0 9.6 9 09/06/2005 23:20:00 2.5 0.5 4.2 1.1 2.3 0.6 4.2 0.4 1.4 0.7 3.4 0.4 71 14 43 255 9.6 0 9.8 9.6 09/06/2005 23:30:00 2.1 0.6 3.4 0.7 1.8 0.7 3.4 0.4 1.1 0.7 2.6 0.4 61 11 66 255 9.7 0 9.8 9.6 09/06/2005 23:40:00 2.2 0.4 3.4 1.1 1.7 0.5 3.4 0.4 1 0.5 2.3 0.4 72 12 73 255 9.8 0 9.8 9.6 09/06/2005 23:50:00 2 0.4 3 1.1 1.6 0.4 2.6 0.7 1 0.5 1.9 0.4 70 11 56 255 9.8 0 9.8 9.6 09/07/2005 00:00:00 1.9 0.3 3 1.1 1.5 0.4 2.6 0.4 0.8 0.4 2.3 0.4 69 8 65 255 9.7 0 9.8 9.6 09/07/2005 00:10:00 1.9 0.4 3 0.4 1.5 0.5 2.6 0.4 0.7 0.4 1.9 0.4 67 9 37 255 9.7 0 9.8 9.6 09/07/2005 00:20:00 1.8 0.5 3 0.7 1.5 0.5 2.6 0.4 0.9 0.5 2.3 0.4 66 9 47 255 9.6 0 9.8 9.6 09/07/2005 00:30:00 2.1 0.6 4.2 1.1 1.6 0.7 3.8 0.4 1 0.6 3 0.4 55 10 98 255 9.8 0 9.8 9.6 09/07/2005 00:40:00 2.4 0.7 4.6 0.7 2 0.8 4.6 0.4 1.3 0.8 3.4 0.4 57 17 44 255 9.9 0 10.1 9.6 09/07/2005 00:50:00 2.5 0.7 4.2 0.7 2.2 0.8 3.8 0.4 1.5 0.7 3.8 0.4 58 13 47 255 10 0 10.1 9.8 09/07/2005 01:00:00 2.1 0.6 3.4 0.7 1.9 0.6 3.8 0.4 1.1 0.7 2.6 0.4 48 13 61 255 10 0 10.1 9.8 09/07/2005 01:10:00 2.1 0.4 3.4 1.1 1.7 0.5 3 0.4 1.2 0.5 2.6 0.4 55 21 66 255 9.9 0 10.1 9.8 09/07/2005 01:20:00 1.9 0.5 3.4 0.4 1.3 0.6 3 0.4 0.8 0.6 2.6 0.4 68 14 59 255 9.8 0 10.1 9.6 09/07/2005 01:30:00 1.8 0.6 3 0.4 1.2 0.7 2.3 0.4 0.9 0.6 2.3 0.4 55 14 63 255 9.7 0 9.8 9.6 09/07/2005 01:40:00 1.9 0.5 3 0.7 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 58 9 52 255 9.6 0 9.8 9.6 09/07/2005 01:50:00 1.7 0.6 3.4 0.4 1.2 0.7 3.4 0.4 0.8 0.6 2.6 0.4 63 12 68 255 9.6 0 9.6 9.6 09/07/2005 02:00:00 1.4 0.8 3 0.4 1 0.8 2.6 0.4 0.7 0.5 2.3 0.4 78 15 84 255 9.5 0 9.6 9.3 09/07/2005 02:10:00 1.9 0.7 3.8 0.4 1.6 0.8 3.4 0.4 0.9 0.6 3 0.4 72 16 83 255 9.5 0 9.6 9.3 09/07/2005 02:20:00 1.9 0.6 3.4 0.4 1.5 0.7 3.4 0.4 1 0.6 2.6 0.4 66 13 55 255 9.6 0 9.6 9.6 09/07/2005 02:30:00 2.1 0.6 3.8 0.7 1.8 0.7 3.8 0.4 0.9 0.6 2.6 0.4 57 17 47 255 9.6 0 9.6 9.6 09/07/2005 02:40:00 2 0.5 3.4 1.1 1.6 0.6 3 0.4 1 0.5 2.3 0.4 60 13 60 255 9.6 0 9.6 9.6 09/07/2005 02:50:00 2.1 0.5 3 0.7 1.5 0.7 3 0.4 0.9 0.6 2.3 0.4 53 11 55 255 9.6 0 9.8 9.6 09/07/2005 03:00:00 1.1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 54 9 51 255 9.6 0 9.6 9.6 09/07/2005 03:10:00 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 54 4 49 255 9.6 0 9.6 9.6 09/07/2005 03:20:00 1.3 0.3 1.9 0.7 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 83 7 82 255 9.5 0 9.6 9.3 09/07/2005 03:30:00 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 91 32 84 255 9.5 0 9.6 9.3 09/07/2005 03:40:00 0.8 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 0 55 255 9.5 0 9.6 9.3 09/07/2005 03:50:00 1.1 0.2 1.5 0.7 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 31 20 54 255 9.5 0 9.6 9.3 09/07/2005 04:00:00 1.2 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 14 2 11 255 9.4 0 9.6 9.3 09/07/2005 04:10:00 1.3 0.3 1.9 0.7 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 31 8 16 255 9.3 0 9.3 9.3 09/07/2005 04:20:00 1.1 0.2 1.5 0.7 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 40 0 40 255 9.2 0 9.3 9.3 09/07/2005 04:30:00 1.3 0.3 1.9 0.7 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 50 10 59 255 9.2 0 9.3 9 09/07/2005 04:40:00 1.2 0.3 1.9 0.7 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 66 9 74 255 9.1 0 9.3 9 09/07/2005 04:50:00 1.6 0.4 2.6 0.7 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 52 2 57 255 9.1 0 9.3 9 09/07/2005 05:00:00 2.4 0.3 3 1.5 1.9 0.4 2.6 0.7 1.3 0.4 2.3 0.4 73 6 71 255 9.2 0 9.3 9 09/07/2005 05:10:00 2.2 0.4 3 1.1 1.6 0.4 2.6 0.4 0.8 0.4 1.9 0.4 76 9 85 255 9.2 0 9.3 9 09/07/2005 05:20:00 1.2 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 64 13 88 255 9.2 0 9.3 9.3 09/07/2005 05:30:00 1.4 0.3 2.3 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 74 11 60 255 9.2 0 9.3 9.3 09/07/2005 05:40:00 1.9 0.3 2.6 1.5 1.3 0.4 2.3 0.4 0.7 0.3 1.5 0.4 52 18 66 255 9.4 0 9.3 9.3 09/07/2005 05:50:00 1.2 0.5 2.6 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 56 17 64 255 9.4 0 9.6 9.3 09/07/2005 06:00:00 1.1 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 121 27 85 255 9.4 0 9.3 9.3 09/07/2005 06:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 3 149 255 9.4 0 9.6 9.3 09/07/2005 06:20:00 1.7 0.4 2.6 0.7 1.1 0.5 1.9 0.4 0.5 0.2 1.1 0.4 147 11 136 255 9.4 0 9.6 9.3 09/07/2005 06:30:00 1.1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 0.4 0.2 1.5 0.4 102 43 147 255 9.4 0 9.6 9.3 09/07/2005 06:40:00 0.9 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 62 11 63 255 9.5 0 9.6 9.3 09/07/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 4 49 255 9.5 0 9.6 9.3 09/07/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 255 255 9.5 0 9.6 9.6 09/07/2005 07:10:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 122 102 249 255 9.6 0 9.6 9.6 09/07/2005 07:20:00 1.1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 230 45 219 255 9.6 0 9.8 9.6 09/07/2005 07:30:00 1.4 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 358 4 356 255 9.7 0 9.8 9.6 09/07/2005 07:40:00 1.1 0.5 1.9 0.4 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 41 14 23 255 9.8 0 9.8 9.6 09/07/2005 07:50:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 9.8 0 9.8 9.8 09/07/2005 08:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 9.9 0 10.1 9.8 09/07/2005 08:10:00 1.1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 84 26 103 255 10 0 10.1 9.8 09/07/2005 08:20:00 1.1 0.4 2.3 0.4 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 119 7 118 255 10.2 0 10.3 10.1 09/07/2005 08:30:00 1.3 0.5 2.3 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 108 6 98 255 10.4 0 10.6 10.3 09/07/2005 08:40:00 1.6 0.4 2.3 0.7 1 0.5 1.9 0.4 0.6 0.4 1.5 0.4 102 6 111 255 10.6 0 10.6 10.6 09/07/2005 08:50:00 1.3 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.3 1.5 0.4 80 9 91 255 10.8 0 11.1 10.6 09/07/2005 09:00:00 1.9 0.4 2.6 0.7 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 82 16 76 255 11.1 0 11.4 10.9 09/07/2005 09:10:00 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 83 15 86 255 11.4 0 11.7 11.1 09/07/2005 09:20:00 0.8 0.6 2.3 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 86 20 108 255 11.6 0 11.7 11.4 09/07/2005 09:30:00 0.6 0.4 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 41 53 348 255 11.7 0 11.9 11.7 09/07/2005 09:40:00 1.3 0.4 2.3 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.1 0.4 108 9 111 255 11.8 0 11.9 11.7 09/07/2005 09:50:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 36 63 255 12.1 0 12.5 11.9 09/07/2005 10:00:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 70 1 70 255 12.5 0 12.7 12.5 09/07/2005 10:10:00 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 101 41 166 255 13.1 0.2 13.5 12.7 09/07/2005 10:20:00 1.1 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 160 30 191 255 13.4 0 13.5 13.3 09/07/2005 10:30:00 1 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 184 22 177 255 13.4 0 13.5 13.3 09/07/2005 10:40:00 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 197 39 211 255 13.6 0 13.5 13.5 09/07/2005 10:50:00 1.3 0.6 3 0.4 0.7 0.5 2.6 0.4 0.8 0.5 2.6 0.4 214 38 200 255 13.4 0 13.5 13.3 09/07/2005 11:00:00 1.1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 220 24 266 255 13.5 0 13.5 13.3 09/07/2005 11:10:00 1.3 0.8 3.4 0.4 0.9 0.7 3 0.4 0.7 0.6 2.6 0.4 228 12 233 255 13.7 0 14.4 13.3 09/07/2005 11:20:00 3.1 0.8 4.9 0.7 2.7 0.9 4.9 0.4 2 0.9 4.2 0.4 225 22 214 255 13.7 0.1 14.1 13.5 09/07/2005 11:30:00 1.7 0.8 3.8 0.4 1.2 0.8 3.4 0.4 1.1 0.8 3.4 0.4 231 23 213 255 13.7 0 14.4 13.5 09/07/2005 11:40:00 1.4 0.9 3.8 0.4 1.2 0.8 3.4 0.4 1 0.7 3.4 0.4 238 19 249 255 14 0.1 14.6 13.8 09/07/2005 11:50:00 1.8 0.9 4.2 0.4 1.5 0.8 4.2 0.4 1.3 0.8 3.8 0.4 235 29 252 255 14 0.1 14.6 13.8 09/07/2005 12:00:00 1.9 0.9 4.2 0.4 1.4 0.9 3.8 0.4 1.2 0.8 3 0.4 241 22 252 255 13.9 0 14.4 13.5 09/07/2005 12:10:00 2.4 1 4.6 0.4 1.9 1 4.2 0.4 1.5 0.9 3.8 0.4 258 22 253 255 13.8 0 14.4 13.5 09/07/2005 12:20:00 2.2 1 4.9 0.4 1.5 1.1 4.6 0.4 1.2 1 4.2 0.4 249 24 263 255 13.9 0 14.4 13.8 09/07/2005 12:30:00 1.6 0.7 3 0.4 0.9 0.7 3 0.4 0.9 0.6 2.6 0.4 248 30 264 255 14.2 0 14.6 14.1 09/07/2005 12:40:00 1.2 0.7 3 0.4 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 269 24 253 255 14.3 0 14.6 14.1 09/07/2005 12:50:00 2 1 4.6 0.4 1.3 1 4.2 0.4 1.1 0.8 3 0.4 241 30 240 255 14.3 0 14.9 14.4 09/07/2005 13:00:00 2.1 0.8 4.2 0.4 1.5 0.9 3.8 0.4 1.4 0.9 3.8 0.4 245 22 229 255 14.4 0 14.9 14.4 09/07/2005 13:10:00 2 0.9 4.9 0.4 1.4 1 4.6 0.4 1.4 0.9 4.2 0.4 241 19 274 255 14.6 0 15.2 14.6 09/07/2005 13:20:00 2 1.1 4.9 0.4 1.4 1.2 4.9 0.4 1.4 1.1 4.9 0.4 269 23 256 255 14.6 0 15.2 14.6 09/07/2005 13:30:00 2.5 0.9 4.2 0.4 2 1 4.2 0.4 1.7 0.9 3.4 0.4 242 29 206 255 14.8 0 15.2 14.9 09/07/2005 13:40:00 2.1 0.6 4.2 0.4 1.5 0.8 3.4 0.4 1.4 0.7 3 0.4 262 20 243 255 14.7 0 15.5 14.6 09/07/2005 13:50:00 2 0.8 4.2 0.4 1.4 0.9 3.8 0.4 1.4 1 3.8 0.4 268 21 276 255 14.6 0 15.2 14.6 09/07/2005 14:00:00 2 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.5 0.8 3.4 0.4 242 17 255 255 14.6 0.1 15.5 14.4 09/07/2005 14:10:00 1.4 0.5 2.6 0.4 0.9 0.6 3 0.4 0.8 0.5 1.9 0.4 242 20 274 255 15 0.1 15.7 14.9 09/07/2005 14:20:00 1.8 0.9 3.8 0.4 1.4 1 3.4 0.4 1.2 0.9 3.8 0.4 263 13 240 255 15.2 0.2 16 15.2 09/07/2005 14:30:00 0.7 0.6 2.6 0.4 0.5 0.4 2.6 0.4 0.4 0.3 1.5 0.4 260 51 253 255 15.2 0.1 16 15.2 09/07/2005 14:40:00 1.8 0.6 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.8 3.4 0.4 296 23 277 255 15.5 0 16 15.5 09/07/2005 14:50:00 1.3 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.6 2.3 0.4 272 28 314 255 15.2 0.2 16 14.9 09/07/2005 15:00:00 1.8 1.2 5.3 0.4 1.4 1.2 4.9 0.4 1.3 1.1 4.9 0.4 282 22 269 255 15.5 0.1 16.3 15.2 09/07/2005 15:10:00 2.2 1 4.6 0.4 1.8 1.1 4.9 0.4 1.6 0.9 4.6 0.4 252 28 266 255 15.5 0 16 15.2 09/07/2005 15:20:00 2.6 1 5.3 0.4 2.5 1 5.3 0.4 2.1 0.9 4.9 0.4 282 33 310 255 15.6 0.1 16.3 15.2 09/07/2005 15:30:00 2.4 0.7 4.2 0.4 2.2 0.8 3.8 0.4 1.9 0.7 3.8 0.4 296 38 283 255 16.4 0.2 16.8 15.7 09/07/2005 15:40:00 1.6 1 4.2 0.4 1.5 1 4.2 0.4 1.3 0.9 3.8 0.4 260 58 211 255 16.6 0.1 16.8 16.3 09/07/2005 15:50:00 1.2 1 3.4 0.4 1.1 1 4.2 0.4 1 0.8 3 0.4 196 58 190 255 16.4 0.2 16.8 16.3 09/07/2005 16:00:00 1.6 0.8 3 0.4 1.4 0.8 3 0.4 1.4 0.7 3 0.4 105 17 92 255 16 0 16.6 15.7 09/07/2005 16:10:00 1.2 0.6 3 0.4 0.9 0.6 2.3 0.4 1.2 0.6 2.6 0.4 101 41 88 255 15.7 0 16 15.7 09/07/2005 16:20:00 0.9 0.8 3.4 0.4 0.8 0.7 3 0.4 0.8 0.7 3.8 0.4 238 72 317 255 15.7 0 16 15.7 09/07/2005 16:30:00 2.4 0.9 4.6 0.4 2.2 1 4.6 0.4 1.7 1 4.2 0.4 309 22 317 255 15.8 0 16.3 15.7 09/07/2005 16:40:00 1.4 1 3.4 0.4 1.7 0.8 3.4 0.4 1.1 0.8 3.4 0.4 296 24 285 255 15.5 0 16 15.2 09/07/2005 16:50:00 1.4 0.9 3.8 0.4 1.8 0.8 3.8 0.4 1.3 0.8 3.4 0.4 313 21 283 255 15.2 0.1 15.7 14.9 09/07/2005 17:00:00 1.8 0.8 3.8 0.4 2 0.8 3.8 0.4 1.6 0.7 3.4 0.4 303 23 295 255 15 0.1 15.7 14.9 09/07/2005 17:10:00 0.8 0.6 2.6 0.4 1.1 0.7 3 0.4 0.9 0.6 2.6 0.4 301 23 289 255 15.2 0.1 15.7 15.2 09/07/2005 17:20:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.1 0.4 291 20 325 255 15.2 0 15.5 15.2 09/07/2005 17:30:00 0.5 0.3 1.5 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 233 43 275 255 15.2 0.1 15.7 15.2 09/07/2005 17:40:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 239 28 236 255 14.9 0 15.7 14.9 09/07/2005 17:50:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 261 11 284 255 14.8 0.2 15.5 14.6 09/07/2005 18:00:00 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 289 19 250 255 14.5 0.1 15.2 14.4 09/07/2005 18:10:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 250 0 250 255 14.3 0 14.9 14.1 09/07/2005 18:20:00 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 265 12 274 255 14.2 0.1 14.9 13.8 09/07/2005 18:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 290 26 255 255 13.7 0.2 14.4 13.3 09/07/2005 18:40:00 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 332 0 332 255 13 0.2 13.8 12.7 09/07/2005 18:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 42 61 255 255 12.6 0 12.7 12.5 09/07/2005 19:00:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 94 0 255 255 12.4 0 12.5 12.5 09/07/2005 19:10:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 133 22 163 255 12.4 0 12.5 12.2 09/07/2005 19:20:00 1.3 0.3 1.9 0.7 1.6 0.2 2.3 1.1 1 0.4 1.9 0.4 156 8 165 255 12.4 0 12.5 12.2 09/07/2005 19:30:00 0.8 0.3 1.5 0.4 1.2 0.2 1.9 0.4 0.6 0.3 1.5 0.4 156 9 170 255 12.4 0 12.5 12.5 09/07/2005 19:40:00 0.6 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 108 45 148 255 12.4 0 12.5 12.2 09/07/2005 19:50:00 0.5 0.2 1.5 0.4 0.8 0.3 1.9 0.4 0.4 0.1 1.1 0.4 26 5 32 255 12.3 0 12.5 12.2 09/07/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 23 0 255 255 12.1 0 12.2 11.9 09/07/2005 20:10:00 0.4 0.2 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 26 6 39 255 12 0 12.2 11.9 09/07/2005 20:20:00 1.5 0.4 2.3 0.4 1.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 55 8 67 255 11.9 0 11.9 11.7 09/07/2005 20:30:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 48 8 45 255 11.7 0 11.7 11.7 09/07/2005 20:40:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.5 0.3 1.5 0.4 41 4 39 255 11.7 0 11.7 11.4 09/07/2005 20:50:00 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.6 0.3 1.5 0.4 50 7 58 255 11.3 0 11.7 11.1 09/07/2005 21:00:00 2 0.3 2.6 1.1 1.9 0.3 2.6 0.7 0.9 0.4 1.9 0.4 52 6 48 255 11.1 0 11.4 10.9 09/07/2005 21:10:00 1.8 0.3 2.6 0.7 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 42 9 35 255 10.7 0 10.9 10.6 09/07/2005 21:20:00 1.4 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 47 4 35 255 10.3 0.1 10.6 10.3 09/07/2005 21:30:00 1.5 0.4 2.3 0.7 1.2 0.5 2.3 0.4 0.5 0.2 1.1 0.4 43 5 48 255 10 0 10.3 9.8 09/07/2005 21:40:00 1.4 0.3 1.9 0.7 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 36 5 44 255 9.6 0 9.8 9.6 09/07/2005 21:50:00 1.5 0.2 2.3 0.7 1.3 0.3 1.9 0.7 0.4 0 0.7 0.4 34 0 34 255 9.5 0 9.6 9.3 09/07/2005 22:00:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 0.4 0 0.4 0.4 39 6 34 255 9.2 0 9.3 9 09/07/2005 22:10:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 48 0 48 255 8.8 0 9 8.5 09/07/2005 22:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.5 1.9 0.4 197 82 158 255 8.6 0 8.8 8.5 09/07/2005 22:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 167 0 167 255 8.5 0 8.8 8.5 09/07/2005 22:40:00 0.9 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.9 0.4 1.9 0.4 171 3 174 255 8.4 0 8.5 8.3 09/07/2005 22:50:00 1.5 0.5 2.3 0.7 1.3 0.5 2.3 0.7 0.6 0.3 1.5 0.4 157 17 153 255 8.1 0.1 8.3 8 09/07/2005 23:00:00 1.2 0.2 1.9 0.7 1 0.3 1.9 0.4 0.4 0 0.7 0.4 104 18 123 255 7.8 0 8 7.5 09/07/2005 23:10:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 85 0 86 255 7.5 0 7.8 7.5 09/07/2005 23:20:00 0.5 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 85 0 86 255 7.3 0 7.5 7.3 09/07/2005 23:30:00 1.6 0.2 2.3 1.1 1.5 0.3 2.3 0.7 0.9 0.4 1.5 0.4 85 0 86 255 7.3 0 7.5 7.3 09/07/2005 23:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 85 0 86 255 7.4 0 7.5 7.3 09/07/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 0 255 255 7.5 0 7.8 7.3 09/08/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 0 255 255 7.6 0 7.8 7.5 09/08/2005 00:10:00 1.5 0.4 2.3 0.4 1.4 0.4 1.9 0.4 1 0.5 1.9 0.4 124 17 139 255 7.6 0 7.8 7.5 09/08/2005 00:20:00 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.3 1.5 0.4 132 8 118 255 7.5 0 7.5 7.5 09/08/2005 00:30:00 1.9 0.4 3 0.7 1.7 0.4 3 0.7 1.1 0.5 2.3 0.4 126 11 119 255 7.4 0 7.5 7.3 09/08/2005 00:40:00 2.1 0.5 3.4 1.1 2 0.5 3.4 0.7 0.9 0.5 2.6 0.4 121 9 118 255 7.4 0 7.5 7.3 09/08/2005 00:50:00 2.4 0.5 3.8 1.1 2.2 0.5 3.4 1.1 1.5 0.5 2.6 0.4 124 11 124 255 7.3 0 7.3 7.3 09/08/2005 01:00:00 2.6 0.6 4.2 1.5 2.5 0.7 4.2 0.7 1.6 0.6 3.4 0.4 131 9 130 255 7.3 0.1 7.5 7 09/08/2005 01:10:00 3.4 0.5 4.6 2.3 3.2 0.5 4.2 1.9 2.2 0.6 3.4 0.7 126 11 127 255 7.6 0 7.8 7.5 09/08/2005 01:20:00 2.6 0.6 4.6 0.7 2.2 0.7 4.2 0.4 1.3 0.7 3.8 0.4 122 13 104 255 7.6 0.1 7.8 7.3 09/08/2005 01:30:00 1.7 0.7 3.8 0.4 1.2 0.8 3 0.4 0.7 0.5 2.3 0.4 119 18 110 255 7.3 0 7.5 7.3 09/08/2005 01:40:00 1.2 0.6 3 0.4 0.8 0.6 2.6 0.4 0.5 0.3 1.9 0.4 119 26 112 255 7.3 0 7.5 7.3 09/08/2005 01:50:00 1.6 0.7 3.4 0.4 1.2 0.6 3 0.4 0.6 0.5 2.6 0.4 110 17 130 255 7.4 0 7.5 7.3 09/08/2005 02:00:00 2.4 0.5 3.8 1.1 2 0.6 3.4 0.4 1 0.6 2.6 0.4 115 15 113 255 7.7 0 7.8 7.5 09/08/2005 02:10:00 2.2 0.5 3.4 1.1 1.8 0.6 3.4 0.4 0.7 0.4 1.9 0.4 93 13 105 255 7.7 0 7.8 7.5 09/08/2005 02:20:00 1.8 0.5 3.4 0.4 1.3 0.6 3 0.4 0.5 0.3 1.9 0.4 93 12 100 255 7.2 0 7.5 7 09/08/2005 02:30:00 2.5 0.5 3.8 1.1 2.2 0.6 3.4 0.4 1 0.6 2.6 0.4 104 13 111 255 7 0 7 7 09/08/2005 02:40:00 2.7 0.4 4.2 1.1 2.4 0.5 3.8 1.1 1.2 0.6 2.6 0.4 93 11 83 255 7.1 0 7.3 7 09/08/2005 02:50:00 2.6 0.4 3.8 1.5 2.2 0.5 3.4 0.7 1.2 0.6 2.3 0.4 107 13 109 255 6.7 0.1 7.3 6.5 09/08/2005 03:00:00 2.6 0.6 3.8 0.7 2.2 0.6 3.4 0.4 1.1 0.5 2.6 0.4 105 11 96 255 6.7 0.1 7 6.5 09/08/2005 03:10:00 2.5 0.4 3.8 1.5 2.2 0.5 3.4 0.7 1.2 0.5 2.6 0.4 111 11 107 255 6.7 0.2 7 6.2 09/08/2005 03:20:00 2.5 0.5 3.8 1.1 2.1 0.6 3.4 0.4 0.8 0.5 2.3 0.4 109 11 108 255 6.2 0 6.2 6 09/08/2005 03:30:00 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 0.5 0.2 1.9 0.4 116 10 105 255 5.9 0 6.2 5.7 09/08/2005 03:40:00 2.1 0.5 3.4 0.7 1.7 0.6 3 0.4 0.6 0.3 1.9 0.4 113 9 97 255 5.9 0 6 5.7 09/08/2005 03:50:00 2.5 0.5 3.8 1.1 2.2 0.5 3.4 0.4 1 0.5 2.3 0.4 111 11 95 255 5.8 0 6 5.7 09/08/2005 04:00:00 2.6 0.5 3.8 1.5 2.2 0.6 3.4 0.7 1 0.6 3 0.4 113 12 97 255 5.7 0 5.7 5.7 09/08/2005 04:10:00 2.7 0.5 3.8 1.1 2.4 0.5 3.8 0.4 1 0.6 2.6 0.4 106 12 100 255 5.7 0 6 5.7 09/08/2005 04:20:00 2.8 0.6 4.2 1.5 2.6 0.6 4.2 0.7 1.3 0.7 3 0.4 106 11 91 255 5.8 0 6 5.7 09/08/2005 04:30:00 2.8 0.5 3.8 1.9 2.5 0.5 3.8 1.1 1.3 0.6 3 0.4 110 12 98 255 5.8 0 6 5.7 09/08/2005 04:40:00 2.2 0.6 3.8 0.4 1.9 0.7 3.4 0.4 0.7 0.5 2.3 0.4 114 15 95 255 5.9 0 6 5.7 09/08/2005 04:50:00 2.5 0.6 3.8 1.1 2.2 0.6 3.8 0.4 0.9 0.6 3 0.4 111 13 107 255 5.8 0 6 5.7 09/08/2005 05:00:00 2.3 0.7 3.8 0.7 2 0.8 3.4 0.4 1 0.6 2.6 0.4 113 13 105 255 5.6 0 5.7 5.5 09/08/2005 05:10:00 2.4 0.5 3.8 1.1 2 0.6 3.4 0.4 0.9 0.5 2.3 0.4 114 13 110 255 5.6 0 5.7 5.5 09/08/2005 05:20:00 2.3 0.6 3.8 1.1 2 0.6 3.8 0.4 0.9 0.5 2.3 0.4 118 14 125 255 5.6 0 5.7 5.5 09/08/2005 05:30:00 2.4 0.6 3.8 0.7 2.1 0.7 3.4 0.4 1.1 0.6 2.6 0.4 117 15 116 255 5.6 0 5.7 5.5 09/08/2005 05:40:00 2.2 0.6 3.8 0.4 1.7 0.7 3.8 0.4 0.8 0.6 3 0.4 123 15 102 255 5.9 0 6 5.7 09/08/2005 05:50:00 2.4 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.2 0.6 2.6 0.4 123 14 131 255 5.9 0 6 5.7 09/08/2005 06:00:00 2.6 0.4 3.8 1.1 2.3 0.5 3.8 0.7 1.3 0.6 2.6 0.4 124 11 133 255 5.6 0 6 5.5 09/08/2005 06:10:00 2.7 0.6 4.2 1.1 2.4 0.6 3.8 0.4 1.3 0.7 2.6 0.4 120 13 108 255 5.4 0 5.7 5.2 09/08/2005 06:20:00 2.5 0.5 3.8 1.5 2.2 0.6 3.8 0.7 1 0.5 2.6 0.4 116 12 113 255 5.2 0 5.5 5.2 09/08/2005 06:30:00 2.6 0.5 4.2 1.1 2.3 0.6 3.4 0.4 1.5 0.6 3 0.4 126 12 142 255 5.3 0 5.7 5 09/08/2005 06:40:00 3 0.6 4.2 1.9 2.9 0.6 4.2 1.5 2.3 0.6 3.8 0.4 126 10 118 255 5.8 0.1 6.2 5.5 09/08/2005 06:50:00 3 0.7 4.6 1.1 2.9 0.7 4.2 1.1 2.1 0.7 3.8 0.4 125 13 127 255 6.2 0.1 6.7 6 09/08/2005 07:00:00 2.3 0.9 3.8 0.4 2 0.9 3.8 0.4 1.3 0.8 3.8 0.4 119 15 129 255 6.9 0.1 7.3 6.5 09/08/2005 07:10:00 1 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.4 0.2 1.5 0.4 94 15 105 255 7.3 0.2 7.8 7 09/08/2005 07:20:00 0.6 0.3 2.3 0.4 0.4 0.3 1.9 0.4 0.4 0.1 1.5 0.4 124 13 106 255 8.1 0.1 8.5 7.8 09/08/2005 07:30:00 1.6 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.4 1.9 0.4 98 13 102 255 8.7 0.2 9 8.3 09/08/2005 07:40:00 1.6 0.4 2.6 0.7 1.1 0.4 2.3 0.4 0.5 0.2 1.5 0.4 106 12 105 255 8.3 0.4 9 7.5 09/08/2005 07:50:00 1.7 0.3 2.3 1.1 1.2 0.4 2.3 0.4 0.6 0.4 1.5 0.4 100 5 97 255 7.5 0 7.8 7.3 09/08/2005 08:00:00 1.8 0.3 2.6 1.1 1.5 0.4 2.3 0.4 0.9 0.5 1.9 0.4 101 6 104 255 8.5 0.6 9.6 7.5 09/08/2005 08:10:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 98 9 94 255 10.2 0.3 10.6 9.6 09/08/2005 08:20:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 101 11 106 255 10.8 0.1 11.1 10.6 09/08/2005 08:30:00 1.6 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 1.9 0.4 97 9 97 255 11.4 0 11.7 11.1 09/08/2005 08:40:00 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 96 17 90 255 11.7 0 11.9 11.4 09/08/2005 08:50:00 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.6 2.3 0.4 75 22 98 255 12.1 0.2 12.5 11.7 09/08/2005 09:00:00 1.9 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1.7 0.4 2.6 0.4 74 21 79 255 12.5 0 12.7 12.5 09/08/2005 09:10:00 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 1.5 0.6 2.6 0.4 74 11 68 255 12.6 0 12.7 12.5 09/08/2005 09:20:00 1.6 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 62 30 85 255 13 0.1 13.3 12.7 09/08/2005 09:30:00 1.9 0.5 3 0.4 1.9 0.5 3.4 0.7 1.7 0.6 2.6 0.4 67 16 66 255 13.3 0 13.5 13.3 09/08/2005 09:40:00 1.7 0.4 2.6 0.4 1.6 0.4 2.6 0.4 1.4 0.5 2.3 0.4 68 16 78 255 13.5 0.1 14.4 13.3 09/08/2005 09:50:00 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 0.9 0.6 2.6 0.4 57 26 86 255 14.1 0.1 14.6 13.8 09/08/2005 10:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 62 22 83 255 14.4 0 14.6 14.4 09/08/2005 10:10:00 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 50 20 359 255 14.8 0.2 15.5 14.4 09/08/2005 10:20:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 43 27 56 255 14.9 0.1 15.5 14.6 09/08/2005 10:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 9 38 4 255 15.1 0 15.5 14.9 09/08/2005 10:40:00 1.1 0.5 2.3 0.4 1 0.5 2.6 0.4 0.8 0.4 2.3 0.4 16 30 21 255 15.4 0 16 15.2 09/08/2005 10:50:00 1.6 0.5 3 0.4 1.5 0.5 3 0.4 1.5 0.5 2.6 0.4 14 14 21 255 15.7 0 16.3 15.5 09/08/2005 11:00:00 1.5 0.7 3 0.4 1.4 0.7 2.6 0.4 1.4 0.6 2.6 0.4 24 24 18 255 15.5 0.2 16.3 14.9 09/08/2005 11:10:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1 0.6 2.6 0.4 5 21 15 255 15 0 15.5 14.9 09/08/2005 11:20:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 290 36 274 255 15 0.1 15.7 14.9 09/08/2005 11:30:00 1.8 0.5 3 0.4 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 12 16 13 255 15.9 0.1 16.3 15.5 09/08/2005 11:40:00 1 0.5 2.3 0.4 0.9 0.4 2.3 0.4 1 0.5 2.6 0.4 47 32 42 255 16.1 0 16.6 16 09/08/2005 11:50:00 1.7 0.7 3 0.4 1.6 0.7 3 0.4 1.5 0.7 3 0.4 42 45 38 255 16.1 0.1 16.8 16 09/08/2005 12:00:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 1 0.5 1.9 0.4 65 17 42 255 15.9 0 16.3 15.7 09/08/2005 12:10:00 1.8 0.4 3 0.7 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 40 16 28 255 15.9 0 16.3 15.7 09/08/2005 12:20:00 1.1 0.6 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 321 36 287 255 16.1 0.1 16.8 15.7 09/08/2005 12:30:00 1.3 0.6 2.6 0.4 1.2 0.5 2.3 0.4 1 0.5 2.6 0.4 351 26 340 255 16.7 0.3 17.1 16.3 09/08/2005 12:40:00 1.4 0.6 2.6 0.4 1.3 0.5 2.3 0.4 1.1 0.6 2.6 0.4 36 27 45 255 17.2 0 17.4 17.1 09/08/2005 12:50:00 1.8 0.5 3.4 0.4 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 3 15 340 255 17.3 0 18 16.8 09/08/2005 13:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 44 38 8 255 17.2 0.2 17.7 16.8 09/08/2005 13:10:00 1.7 0.8 3.4 0.4 1.5 0.6 3 0.4 1.4 0.8 3.4 0.4 322 30 334 255 17.8 0 18.2 17.7 09/08/2005 13:20:00 0.9 0.6 2.6 0.4 0.8 0.5 2.6 0.4 0.6 0.5 2.3 0.4 40 82 325 255 18.1 0.3 18.8 17.7 09/08/2005 13:30:00 2 0.6 3 0.4 1.8 0.5 3 0.4 1.6 0.6 3 0.4 338 26 325 255 19 0 19.4 18.5 09/08/2005 13:40:00 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0 47 282 255 19 0.1 19.4 18.8 09/08/2005 13:50:00 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 304 49 259 255 19.7 0.2 20 19.1 09/08/2005 14:00:00 1.7 0.9 3.8 0.4 1.6 0.8 3.4 0.4 1.2 0.7 3 0.4 329 41 16 255 19.9 0.1 20.8 19.7 09/08/2005 14:10:00 2.3 0.9 4.2 0.4 2.1 0.9 4.2 0.4 1.7 1 4.6 0.4 333 28 295 255 20 0 20.5 19.7 09/08/2005 14:20:00 1.6 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.2 0.7 3.4 0.4 288 41 313 255 20 0 20.5 19.7 09/08/2005 14:30:00 2 0.9 3.8 0.4 2 0.9 4.2 0.4 1.7 0.9 3.8 0.4 295 22 302 255 20 0 20.5 19.7 09/08/2005 14:40:00 2.7 1 5.3 0.4 2.6 1 4.9 0.4 2.1 1 5.3 0.4 297 29 300 255 19.7 0 20 19.4 09/08/2005 14:50:00 2.5 0.8 4.6 0.7 2.4 0.8 4.9 0.4 2.1 0.8 3.8 0.4 292 22 293 255 19.2 0 19.7 19.1 09/08/2005 15:00:00 2.3 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.7 1 3.4 0.4 296 20 314 255 18.7 0.2 19.4 18.2 09/08/2005 15:10:00 2.2 0.8 4.2 0.4 2 0.8 4.2 0.4 1.7 0.9 3.8 0.4 306 24 314 255 17.8 0 18.2 17.7 09/08/2005 15:20:00 1.7 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3.4 0.4 296 38 260 255 17.7 0.1 18.2 17.4 09/08/2005 15:30:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.3 0.7 3 0.4 305 22 300 255 17.5 0.1 18 17.1 09/08/2005 15:40:00 2 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.8 3 0.4 324 28 347 255 17.4 0 17.7 17.1 09/08/2005 15:50:00 1.6 0.6 3 0.4 1.5 0.5 3 0.4 1.4 0.6 3 0.4 294 17 311 255 18.1 0.3 18.8 17.4 09/08/2005 16:00:00 1.3 0.6 3.4 0.4 1.2 0.6 3 0.4 0.9 0.5 2.3 0.4 314 29 335 255 18.6 0.1 18.8 18.2 09/08/2005 16:10:00 1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.7 0.5 2.3 0.4 288 30 278 255 17.8 0.2 18.2 17.4 09/08/2005 16:20:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 312 27 315 255 17.4 0 17.7 17.1 09/08/2005 16:30:00 1 0.7 2.6 0.4 1 0.6 2.6 0.4 0.9 0.7 2.6 0.4 304 35 303 255 17.3 0 17.4 17.1 09/08/2005 16:40:00 1.8 0.5 3 0.4 1.8 0.6 3 0.4 1.5 0.5 2.6 0.4 277 16 262 255 16.8 0.1 17.1 16.6 09/08/2005 16:50:00 1.4 0.5 2.3 0.4 1.3 0.4 2.3 0.4 1 0.5 2.3 0.4 280 15 288 255 16.4 0 16.8 16.3 09/08/2005 17:00:00 1.3 0.6 2.3 0.4 1.3 0.6 2.3 0.4 1.1 0.6 2.3 0.4 295 12 277 255 16.4 0 16.8 16.3 09/08/2005 17:10:00 1 0.7 2.6 0.4 0.9 0.7 2.6 0.4 0.8 0.6 2.3 0.4 298 5 298 255 16 0.1 16.8 15.7 09/08/2005 17:20:00 1 0.6 3 0.4 0.9 0.5 2.6 0.4 0.6 0.5 2.6 0.4 316 29 351 255 15.5 0.2 16.3 15.2 09/08/2005 17:30:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 295 13 280 255 15.1 0.1 15.7 14.9 09/08/2005 17:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 307 8 305 255 14.7 0 15.5 14.6 09/08/2005 17:50:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 304 21 306 255 14.3 0.2 14.9 14.1 09/08/2005 18:00:00 2 0.7 3.4 0.4 1.6 0.6 3 0.4 1.2 0.7 2.6 0.4 335 7 318 255 13.9 0 14.6 13.8 09/08/2005 18:10:00 1.3 0.5 2.6 0.4 1.1 0.4 2.3 0.4 0.6 0.4 2.3 0.4 339 11 347 255 13.5 0 13.8 13.3 09/08/2005 18:20:00 1.6 0.3 2.3 1.1 1.3 0.3 2.3 0.4 0.6 0.3 1.5 0.4 347 4 350 255 13.2 0 13.5 13 09/08/2005 18:30:00 1.3 0.2 1.9 0.7 1.1 0.2 1.9 0.7 0.4 0 0.7 0.4 357 4 349 255 13.1 0 13.5 13 09/08/2005 18:40:00 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 359 0 358 255 13.1 0 13.5 13 09/08/2005 18:50:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.5 0.3 1.9 0.4 8 7 17 255 12.9 0 13.5 12.7 09/08/2005 19:00:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.5 0.2 1.1 0.4 18 6 41 255 12.7 0 13.3 12.5 09/08/2005 19:10:00 0.8 0.3 1.5 0.4 0.7 0.3 1.9 0.4 0.4 0.1 1.1 0.4 20 5 19 255 12.3 0 12.5 12.2 09/08/2005 19:20:00 1.5 0.4 2.3 0.4 1.4 0.3 2.3 0.7 0.7 0.4 1.9 0.4 39 7 37 255 11.9 0.1 12.2 11.7 09/08/2005 19:30:00 1.4 0.3 2.3 0.7 1.3 0.3 2.3 0.4 0.6 0.3 1.1 0.4 43 11 32 255 11.6 0 11.7 11.4 09/08/2005 19:40:00 1.8 0.3 2.6 0.7 1.7 0.3 2.6 0.7 1.1 0.3 1.9 0.4 64 7 40 255 11.3 0 11.7 11.1 09/08/2005 19:50:00 2 0.4 2.6 1.1 1.9 0.4 2.6 0.7 1.1 0.4 1.9 0.4 56 7 58 255 10.9 0.1 11.1 10.6 09/08/2005 20:00:00 2 0.3 3 1.5 1.9 0.3 2.6 1.1 1 0.4 1.9 0.4 73 8 63 255 10.6 0 10.9 10.6 09/08/2005 20:10:00 1.9 0.3 2.6 1.1 1.8 0.4 2.6 0.7 0.9 0.4 1.9 0.4 78 9 68 255 10.3 0.1 10.6 10.3 09/08/2005 20:20:00 2.2 0.3 3.4 1.5 2 0.3 2.6 1.1 1.1 0.5 2.3 0.4 78 10 93 255 10.2 0 10.3 10.1 09/08/2005 20:30:00 2.5 0.5 3.4 1.1 2.3 0.5 3.8 1.1 1.1 0.6 2.6 0.4 86 9 80 255 10 0 10.1 9.8 09/08/2005 20:40:00 3.1 0.4 4.2 1.9 3 0.5 4.2 1.5 1.7 0.5 3.4 0.4 83 10 80 255 10 0 10.1 9.8 09/08/2005 20:50:00 3.3 0.5 4.6 1.9 3.2 0.5 4.2 1.9 1.9 0.6 3.4 0.4 79 8 82 255 9.8 0 10.1 9.6 09/08/2005 21:00:00 3 0.4 4.2 1.9 2.8 0.5 3.8 1.5 1.9 0.5 3.4 0.7 86 9 86 255 9.6 0 9.8 9.6 09/08/2005 21:10:00 3.5 0.4 4.6 2.3 3.4 0.5 4.6 2.3 2.3 0.5 3.4 1.1 81 8 84 255 9.6 0 9.8 9.6 09/08/2005 21:20:00 4 0.5 5.7 2.3 3.9 0.5 5.3 1.9 2.8 0.5 4.2 1.1 79 8 66 255 9.8 0 10.1 9.6 09/08/2005 21:30:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 1.9 2.2 0.7 4.2 0.4 79 9 72 255 10.2 0 10.6 10.1 09/08/2005 21:40:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.9 2.2 0.5 3.8 1.1 76 9 72 255 10.2 0 10.3 10.1 09/08/2005 21:50:00 3.4 0.6 4.9 1.5 3.4 0.6 5.3 1.5 2.3 0.7 4.6 0.7 77 10 73 255 10 0 10.3 9.8 09/08/2005 22:00:00 3.5 0.5 4.9 2.3 3.3 0.5 4.9 2.3 2.3 0.5 3.4 1.1 89 8 93 255 9.9 0 10.1 9.8 09/08/2005 22:10:00 3.7 0.5 5.3 2.3 3.7 0.5 5.3 2.3 2.6 0.5 3.8 1.5 91 8 95 255 9.9 0 10.1 9.8 09/08/2005 22:20:00 3.5 0.5 5.3 2.3 3.4 0.5 4.9 2.3 2.4 0.5 4.2 1.1 90 10 84 255 10 0.1 10.3 9.8 09/08/2005 22:30:00 3.8 0.5 4.9 2.3 3.6 0.5 4.6 2.3 2.7 0.6 4.2 1.1 96 9 95 255 10 0 10.3 9.8 09/08/2005 22:40:00 3.9 0.5 5.3 2.6 3.8 0.5 4.9 2.3 2.8 0.7 4.2 0.7 105 11 101 255 10.2 0 10.6 10.1 09/08/2005 22:50:00 4.1 0.6 5.3 2.6 4 0.6 5.3 2.3 3 0.7 4.6 1.1 106 10 109 255 10.5 0.1 10.9 10.3 09/08/2005 23:00:00 4.4 0.4 5.7 3 4.3 0.4 5.3 3 3.3 0.6 4.6 1.5 102 7 97 255 10.7 0 10.9 10.6 09/08/2005 23:10:00 4.4 0.4 5.3 2.6 4.3 0.4 5.3 2.3 3.4 0.6 4.9 1.5 104 7 111 255 10.9 0 11.1 10.9 09/08/2005 23:20:00 4.5 0.8 6.1 1.5 4.4 0.7 5.7 1.9 3.2 0.8 4.9 1.5 110 11 124 255 10.8 0 11.1 10.9 09/08/2005 23:30:00 4.2 0.6 5.7 2.3 4.1 0.6 5.3 1.9 2.8 0.8 4.6 0.7 109 11 98 255 11.1 0 11.1 10.9 09/08/2005 23:40:00 4.4 0.7 6.1 2.6 4.2 0.7 5.7 1.9 3.2 0.8 5.3 1.1 110 11 110 255 11.1 0 11.1 11.1 09/08/2005 23:50:00 4.3 0.6 5.7 1.9 4.2 0.6 5.7 1.9 3.1 0.7 4.9 1.1 104 11 91 255 11.1 0 11.4 11.1 09/09/2005 00:00:00 4.3 0.6 5.7 2.3 4.3 0.7 5.7 1.9 3.3 0.8 4.9 1.1 102 12 106 255 11.3 0 11.4 11.1 09/09/2005 00:10:00 4.6 0.8 6.5 2.3 4.5 0.8 6.1 1.9 3.7 0.8 5.3 1.5 104 13 112 255 11.3 0 11.4 11.4 09/09/2005 00:20:00 4.8 0.7 6.8 2.6 4.7 0.8 6.5 2.6 3.7 0.8 5.7 1.9 107 12 115 255 11.3 0 11.4 11.1 09/09/2005 00:30:00 4.8 1 7.2 1.9 4.8 1 7.2 1.9 3.8 1 6.8 1.5 111 13 127 255 11.4 0 11.7 11.4 09/09/2005 00:40:00 5.3 0.9 7.2 2.6 5.2 0.9 6.8 2.3 4.1 1 6.8 1.5 110 11 111 255 11.5 0 11.7 11.4 09/09/2005 00:50:00 5.1 0.8 6.8 3 5 0.8 6.8 2.3 4.1 0.9 6.5 1.5 106 13 101 255 11.6 0 11.7 11.4 09/09/2005 01:00:00 4 0.9 6.1 1.9 3.9 1 6.1 1.5 3.1 1 5.3 0.4 98 17 86 255 11.7 0 11.7 11.7 09/09/2005 01:10:00 4.7 0.7 6.8 3 4.6 0.7 6.5 3 3.6 0.8 6.5 1.5 108 13 95 255 11.6 0 11.7 11.7 09/09/2005 01:20:00 4.9 0.8 6.5 2.6 4.8 0.8 6.8 2.3 3.7 1 5.7 1.1 110 15 109 255 11.7 0 11.7 11.7 09/09/2005 01:30:00 4.7 0.9 6.8 2.3 4.6 0.9 6.5 2.6 3.6 1 6.5 1.1 112 16 106 255 11.7 0 11.9 11.7 09/09/2005 01:40:00 4.5 1.1 7.2 2.3 4.4 1.1 6.8 1.9 3.4 1 6.1 1.1 114 16 109 255 11.7 0 11.9 11.7 09/09/2005 01:50:00 4.3 0.8 6.5 1.9 4.2 0.8 5.7 2.3 3.4 0.8 5.7 1.5 117 16 106 255 11.8 0 11.9 11.7 09/09/2005 02:00:00 4.2 0.9 6.8 1.9 4.1 1 6.5 1.5 2.9 1 5.3 0.4 110 16 113 255 12 0 12.2 11.9 09/09/2005 02:10:00 3.9 0.9 5.7 1.1 3.9 0.8 5.7 1.9 2.8 0.9 4.9 0.4 106 16 112 255 12 0 12.2 11.9 09/09/2005 02:20:00 4.1 0.7 6.1 2.3 4 0.7 5.7 1.9 3.1 0.8 4.9 0.7 102 11 100 255 12.1 0 12.2 11.9 09/09/2005 02:30:00 3.7 0.7 5.3 1.5 3.5 0.8 5.3 1.1 2.6 0.7 4.6 0.4 104 15 116 255 12.3 0 12.5 12.2 09/09/2005 02:40:00 4.1 0.9 6.1 1.5 3.9 0.9 5.7 0.7 3.1 0.9 5.3 0.4 104 15 111 255 12.3 0 12.5 12.2 09/09/2005 02:50:00 3.8 1 6.5 1.5 3.7 1 6.8 0.7 2.7 1 4.9 0.4 103 19 136 255 12.2 0 12.2 11.9 09/09/2005 03:00:00 4.4 0.9 6.8 1.9 4.4 1 6.8 1.5 3.6 0.9 6.1 1.1 104 15 125 255 12.1 0 12.2 11.9 09/09/2005 03:10:00 5 0.8 7.2 2.6 5 0.8 6.8 2.3 4.1 1 6.5 1.5 99 13 104 255 12.3 0 12.2 12.2 09/09/2005 03:20:00 5.1 1 7.6 2.6 5 1 7.2 2.6 4 1.1 6.8 1.9 99 15 124 255 12.3 0 12.5 12.2 09/09/2005 03:30:00 4.5 1 7.2 1.5 4.4 1 6.8 2.3 3.5 1 5.7 0.7 96 15 97 255 12.5 0 12.5 12.5 09/09/2005 03:40:00 3.5 1 6.1 1.1 3.4 1.1 6.1 0.7 2.4 1.1 6.1 0.4 96 19 74 255 12.5 0 12.7 12.5 09/09/2005 03:50:00 3.5 0.9 5.7 1.5 3.3 0.9 5.7 0.7 2.8 0.9 4.9 0.4 105 17 118 255 12.4 0 12.7 12.2 09/09/2005 04:00:00 2.7 0.8 5.3 0.7 2.4 1 4.9 0.4 1.8 0.9 4.6 0.4 102 17 85 255 12.4 0 12.5 12.2 09/09/2005 04:10:00 2.9 1.2 6.1 0.4 2.5 1.3 6.1 0.4 2 1.2 4.9 0.4 95 16 96 255 12.2 0 12.5 11.9 09/09/2005 04:20:00 3.3 1.2 5.7 0.4 3.2 1.2 5.3 0.4 2.3 1.1 5.3 0.4 95 17 96 255 12.3 0.1 12.5 12.2 09/09/2005 04:30:00 4.1 0.7 5.7 2.3 4 0.7 5.7 2.3 3.1 0.8 5.3 0.4 95 16 85 255 12.2 0 12.5 12.2 09/09/2005 04:40:00 3.7 0.7 5.3 1.9 3.6 0.7 5.7 1.9 2.8 0.8 5.3 0.7 91 15 66 255 12.3 0 12.5 12.2 09/09/2005 04:50:00 3.9 0.6 5.3 1.9 3.8 0.7 5.3 1.9 3.1 0.7 5.3 0.7 107 15 144 255 12.3 0 12.5 12.2 09/09/2005 05:00:00 4.2 0.8 6.1 2.6 4 0.8 6.1 2.3 3.2 0.8 5.3 1.5 105 12 133 255 11.9 0 12.2 11.9 09/09/2005 05:10:00 4 0.9 6.5 1.9 3.8 0.9 6.1 1.5 3 0.8 5.7 0.7 104 15 106 255 12 0 12.2 11.9 09/09/2005 05:20:00 4.8 1.1 7.6 1.9 4.7 1.1 7.6 1.9 3.8 1 6.5 1.5 100 16 118 255 12.1 0 12.2 11.9 09/09/2005 05:30:00 4.9 0.9 7.2 3 4.9 0.9 7.2 3 3.9 0.9 6.5 1.9 89 13 91 255 12 0 12.2 11.9 09/09/2005 05:40:00 4.5 0.8 6.8 2.3 4.5 0.8 6.8 2.6 3.4 0.9 5.7 0.7 88 13 63 255 12.1 0 12.2 11.9 09/09/2005 05:50:00 4.9 1 7.2 2.3 4.8 1 7.2 1.9 3.7 1 6.1 1.5 90 13 84 255 12.3 0 12.5 12.2 09/09/2005 06:00:00 5.2 1 7.6 2.6 5.1 1 7.6 2.3 3.9 1 6.8 1.5 88 13 94 255 12.4 0 12.5 12.2 09/09/2005 06:10:00 4.7 0.9 6.8 2.3 4.6 1 7.6 1.5 3.7 0.9 5.3 1.5 77 15 67 255 12.5 0 12.7 12.5 09/09/2005 06:20:00 4.5 1 7.6 1.9 4.4 1.1 7.2 1.9 3.5 1 6.5 0.7 71 18 86 255 12.7 0 12.7 12.5 09/09/2005 06:30:00 5 0.9 8 3 4.9 1 8.4 2.6 4 0.9 6.5 1.9 80 16 72 255 12.5 0.1 12.7 12.2 09/09/2005 06:40:00 5.1 1 7.6 2.6 4.9 1 7.2 2.6 4 1 6.5 1.1 77 14 69 255 12.3 0 12.5 12.2 09/09/2005 06:50:00 5.4 1.1 8.8 2.3 5.3 1.1 8.4 2.6 4 1.1 7.2 1.1 82 13 93 255 11.9 0.1 12.2 11.7 09/09/2005 07:00:00 5.2 1 8.4 3 5.3 1 8.4 2.3 4.2 1 6.5 1.1 78 14 78 255 11.7 0 11.9 11.7 09/09/2005 07:10:00 5 1 8.8 3 5 1 8.4 3 3.9 1.1 7.2 1.1 85 17 64 255 11.7 0 11.9 11.4 09/09/2005 07:20:00 5.1 1 7.6 2.3 5.1 1 7.6 2.6 4 1 7.2 1.5 78 14 65 255 11.5 0 11.7 11.4 09/09/2005 07:30:00 5.9 1.3 9.1 3.4 5.9 1.3 9.9 3 4.9 1.2 9.5 2.6 64 14 60 255 11.7 0 11.9 11.7 09/09/2005 07:40:00 5.5 1.5 9.5 1.9 5.4 1.5 9.5 1.5 4.4 1.3 8 1.5 69 19 63 255 11.8 0 11.9 11.7 09/09/2005 07:50:00 5.5 1.3 8.8 2.6 5.4 1.3 8.8 2.3 4.4 1.3 7.6 1.9 40 21 32 255 11.7 0 11.7 11.4 09/09/2005 08:00:00 6 1.3 9.9 2.6 6 1.3 9.9 2.6 4.9 1.3 9.5 1.9 25 15 3 255 11.3 0 11.7 11.1 09/09/2005 08:10:00 5.9 1.3 10.3 3 5.9 1.4 9.9 3 4.9 1.2 8 1.9 32 15 12 255 11.1 0 11.4 11.1 09/09/2005 08:20:00 5.1 1.3 8.4 2.3 5.1 1.3 8.8 1.9 4.2 1.3 8.4 1.9 29 12 38 255 11.1 0 11.1 10.9 09/09/2005 08:30:00 4.2 1 6.8 2.3 4.2 1 6.8 2.3 3.5 0.9 6.1 1.1 55 20 34 255 10.9 0 11.1 10.9 09/09/2005 08:40:00 3.7 0.6 5.3 1.9 3.7 0.6 4.9 2.3 2.8 0.8 4.6 0.4 58 15 49 255 10.9 0 10.9 10.9 09/09/2005 08:50:00 4.4 0.8 6.5 2.6 4.4 0.8 6.5 2.6 3.4 0.9 5.7 1.1 64 14 50 255 10.9 0 11.1 10.9 09/09/2005 09:00:00 4.2 0.9 6.5 0.7 4.2 0.9 6.5 0.7 3.1 1 5.7 0.7 83 14 99 255 10.9 0 11.1 10.9 09/09/2005 09:10:00 3.3 0.8 5.3 0.7 3.2 0.9 5.7 0.4 2.3 1 4.6 0.4 95 18 94 255 11 0 11.1 10.9 09/09/2005 09:20:00 5.1 1.3 9.5 2.6 5.1 1.3 9.5 2.3 4.2 1.2 8 0.7 84 23 31 255 11.1 0 11.4 10.9 09/09/2005 09:30:00 5.6 1.3 8.8 2.6 5.6 1.3 8.8 2.6 4.8 1.2 8 1.9 72 19 87 255 11.3 0 11.4 11.1 09/09/2005 09:40:00 6.7 1.5 11.1 3.4 6.7 1.5 9.9 3.8 5.7 1.6 9.5 1.9 71 21 73 255 11.7 0 11.9 11.4 09/09/2005 09:50:00 5.1 1.3 9.5 1.9 5 1.3 8.8 1.5 4.2 1.3 8.4 1.5 79 22 90 255 11.7 0 11.9 11.7 09/09/2005 10:00:00 4.7 1.3 7.6 1.5 4.6 1.3 7.6 1.1 3.6 1.3 7.2 0.4 81 19 105 255 11.5 0 11.7 11.4 09/09/2005 10:10:00 5 1.4 9.9 2.3 5 1.4 9.9 2.6 4.2 1.2 8.4 1.9 60 19 76 255 11.5 0 11.7 11.4 09/09/2005 10:20:00 5.4 1.5 8.8 1.9 5.3 1.5 8.8 1.9 4.4 1.4 7.6 1.1 82 18 85 255 11.6 0 11.7 11.4 09/09/2005 10:30:00 5.5 1.6 10.3 1.5 5.6 1.7 9.9 0.7 4.5 1.5 9.9 1.5 60 21 51 255 11.6 0 11.7 11.4 09/09/2005 10:40:00 6.3 1.6 10.3 1.5 6.3 1.7 11.1 2.3 5.3 1.6 9.5 0.7 57 26 23 255 11.5 0 11.7 11.4 09/09/2005 10:50:00 7.2 2 14.5 3 7.2 2 14.5 3.4 5.9 1.7 11.1 2.3 56 20 15 255 11.5 0 11.7 11.4 09/09/2005 11:00:00 6.5 1.5 11.5 2.3 6.5 1.6 12.2 2.3 5.3 1.6 12.2 1.5 64 18 47 255 11.5 0 11.7 11.4 09/09/2005 11:10:00 6.1 1.7 10.3 2.3 6.1 1.6 10.3 1.9 5.1 1.3 9.1 2.3 61 15 95 255 11.5 0 11.7 11.4 09/09/2005 11:20:00 5.8 1.7 11.1 2.6 5.8 1.7 10.7 2.6 4.9 1.8 9.9 1.5 67 22 51 255 11.6 0 11.7 11.4 09/09/2005 11:30:00 5.7 1.1 9.1 2.6 5.8 1.1 9.1 2.6 4.8 1.2 7.6 1.5 67 23 96 255 11.7 0 11.7 11.7 09/09/2005 11:40:00 5.5 1.3 10.3 2.3 5.7 1.3 9.9 3 4.7 1.5 10.7 1.5 75 18 67 255 11.5 0 11.7 11.4 09/09/2005 11:50:00 5.8 1.3 9.5 3 5.9 1.3 9.5 3 4.7 1.3 9.1 0.4 65 18 96 255 11.5 0 11.7 11.4 09/09/2005 12:00:00 6.8 1.7 10.7 3 6.8 1.6 10.7 3.4 5.5 1.6 9.5 1.9 60 17 45 255 11.7 0 11.9 11.7 09/09/2005 12:10:00 6.1 1.5 11.5 2.6 6.3 1.5 11.1 2.6 5.2 1.4 9.5 2.3 62 20 35 255 11.7 0 11.9 11.7 09/09/2005 12:20:00 5.4 1.3 10.7 3 5.5 1.3 11.5 2.6 4.3 1.2 8.4 1.5 64 22 79 255 11.8 0 11.9 11.7 09/09/2005 12:30:00 5.8 1.5 11.8 2.3 5.9 1.5 11.8 2.6 5 1.6 9.9 1.9 71 19 49 255 11.9 0 12.2 11.7 09/09/2005 12:40:00 6.8 2.2 12.6 1.1 6.8 2.2 13 2.3 5.8 2 12.2 1.5 63 21 61 255 12.1 0.1 12.5 11.9 09/09/2005 12:50:00 7.6 1.6 11.8 4.2 7.6 1.7 11.8 3.8 6.4 1.7 11.8 2.6 58 18 43 255 12.7 0 12.7 12.5 09/09/2005 13:00:00 6.4 1.7 11.5 3 6.4 1.7 11.5 3 5.5 1.5 10.3 2.3 57 19 52 255 12.6 0 12.7 12.5 09/09/2005 13:10:00 6.7 2.1 11.8 1.1 6.7 2.1 11.8 1.9 5.8 1.9 11.5 1.9 53 18 47 255 12.6 0 12.7 12.5 09/09/2005 13:20:00 7.4 1.5 12.6 3.8 7.4 1.5 11.8 3.4 6.1 1.6 11.8 2.3 45 20 38 255 12.7 0 12.7 12.5 09/09/2005 13:30:00 8.3 2.6 15.3 3 8.3 2.6 15.6 3 6.9 2.1 13.3 3 37 15 28 255 12.7 0 13 12.5 09/09/2005 13:40:00 11.4 2.8 21.4 4.2 11.3 2.8 21 4.6 9.4 2.8 17.9 3.4 27 16 33 255 13.2 0 13.3 13 09/09/2005 13:50:00 11.5 2.9 18.7 4.6 11.4 2.9 19.1 4.9 9.5 2.9 16.8 3.4 25 16 7 255 13.3 0 13.5 13.3 09/09/2005 14:00:00 11.1 2.5 17.9 6.1 11.1 2.6 17.9 4.6 9.5 2.6 16.4 4.2 30 15 23 255 13.9 0 13.8 13.5 09/09/2005 14:10:00 11.5 2.4 18.3 5.3 11.5 2.4 17.6 5.7 9 2.5 15.3 3 21 15 34 255 13.9 0 14.1 13.8 09/09/2005 14:20:00 12.6 3.1 20.6 5.3 12.6 3.1 20.2 5.7 9.7 3.1 18.7 3.4 18 12 8 255 14.1 0 14.4 13.8 09/09/2005 14:30:00 12.9 2.5 19.5 5.7 12.9 2.6 19.5 6.1 10.3 2.6 18.3 4.2 22 15 9 255 14.1 0 14.4 13.8 09/09/2005 14:40:00 12.2 2.5 18.3 4.9 12.2 2.5 17.9 4.6 9.5 2.6 16.4 3.4 18 16 25 255 13.9 0 14.4 13.5 09/09/2005 14:50:00 11.9 2.4 19.1 5.7 11.9 2.4 18.7 5.7 9.8 2.5 17.2 4.2 21 13 19 255 13.9 0.1 14.4 13.5 09/09/2005 15:00:00 13.1 3.2 21.4 6.1 13.1 3.2 21.4 6.5 10.7 3.3 19.1 3 23 15 16 255 13.9 0 14.4 13.5 09/09/2005 15:10:00 12.3 3.3 21 4.9 12.2 3.5 20.6 4.6 9.7 3.3 17.6 2.6 21 17 12 255 13.5 0.1 13.8 13 09/09/2005 15:20:00 11.1 2.2 19.1 6.8 11.1 2.2 18.7 7.2 9 2 14.5 4.6 23 13 1 255 12.9 0.1 13.3 12.7 09/09/2005 15:30:00 11.8 2.3 18.3 7.2 11.8 2.4 18.3 6.5 9.9 2.3 16.4 4.9 22 13 6 255 12.8 0 12.7 12.7 09/09/2005 15:40:00 10.5 2 16.1 4.6 10.5 2.1 16.1 4.2 8.1 2.2 14.1 3.4 20 15 52 255 12.7 0 13 12.5 09/09/2005 15:50:00 11.1 2.6 17.9 5.3 11.1 2.7 18.3 4.9 8.9 2.7 15.3 3.4 25 13 16 255 13.1 0 13.3 12.7 09/09/2005 16:00:00 12.7 2.8 21.4 6.5 12.7 2.8 21.4 5.7 10.1 2.8 19.5 3.8 25 15 16 255 13.5 0 13.5 13.3 09/09/2005 16:10:00 11.2 2.4 16.4 6.1 11.1 2.4 16.8 5.7 9 2.6 14.5 3.4 23 17 12 255 13.1 0.2 13.5 12.7 09/09/2005 16:20:00 10.9 2.4 16.1 5.3 10.9 2.4 16.4 5.3 8.6 2.3 14.9 3.8 30 17 28 255 12.8 0 13 12.7 09/09/2005 16:30:00 11.2 2.5 17.9 5.3 11.1 2.5 17.9 5.3 8.5 2.6 16.4 3.4 24 15 3 255 12.8 0 12.7 12.7 09/09/2005 16:40:00 10.9 2.6 17.6 4.9 10.9 2.6 17.6 4.9 8.9 2.6 16.8 3.8 26 17 32 255 12.7 0 12.7 12.5 09/09/2005 16:50:00 10.4 2.4 16.1 3.8 10.4 2.4 15.3 4.6 8.4 2.7 14.9 2.6 19 15 31 255 12.5 0.1 12.7 12.2 09/09/2005 17:00:00 11.2 2.7 18.3 5.7 11.2 2.7 18.3 5.7 8.9 2.9 16.8 2.6 16 16 48 255 12.3 0.1 12.5 11.9 09/09/2005 17:10:00 10.4 2.2 16.4 5.3 10.4 2.2 15.6 5.3 8.1 2.5 14.9 2.3 20 13 39 255 11.7 0 11.9 11.7 09/09/2005 17:20:00 9.9 2.4 16.1 3 9.8 2.5 16.4 2.6 7.2 2.8 14.5 1.5 13 17 18 255 11.5 0 11.9 11.4 09/09/2005 17:30:00 9.9 2.2 16.4 5.3 9.9 2.3 16.1 4.6 7.9 2.6 14.5 2.3 18 15 24 255 11.4 0 11.7 11.4 09/09/2005 17:40:00 10 1.9 14.9 4.9 9.9 2 15.3 4.9 7.9 2.2 14.5 3.8 24 15 40 255 11.5 0 11.7 11.4 09/09/2005 17:50:00 8.6 1.6 13 5.3 8.6 1.6 13.7 4.9 6.2 1.7 12.6 2.6 16 14 51 255 11.2 0 11.4 11.1 09/09/2005 18:00:00 7.4 2 13.7 3.4 7.3 1.9 13 3.4 5.6 1.9 13 1.5 14 14 7 255 11.1 0 11.1 10.9 09/09/2005 18:10:00 7.9 2.3 13.7 2.6 7.8 2.3 14.1 1.9 5.8 2.1 12.6 1.9 14 17 12 255 10.9 0 11.1 10.9 09/09/2005 18:20:00 8.6 1.5 12.6 4.6 8.5 1.5 12.6 4.6 6.6 1.7 10.3 2.6 15 13 27 255 10.9 0 11.1 10.9 09/09/2005 18:30:00 8.7 1.7 13.7 4.6 8.5 1.7 13.3 3.8 6.6 1.9 12.2 1.9 19 14 17 255 11.1 0 11.1 10.9 09/09/2005 18:40:00 8.5 2.1 14.1 4.2 8.4 2.1 14.1 4.2 6.2 2.3 11.8 1.5 13 13 12 255 11 0 11.1 10.9 09/09/2005 18:50:00 8.8 1.7 13.3 4.2 8.7 1.7 13.7 4.2 6.5 2 11.8 1.5 13 13 19 255 10.9 0 11.1 10.9 09/09/2005 19:00:00 7.8 1.5 13 3.8 7.7 1.6 13.3 3.4 5.7 1.8 11.1 1.5 13 13 11 255 10.9 0 11.1 10.9 09/09/2005 19:10:00 8.7 1.3 12.2 5.3 8.7 1.4 12.6 5.3 6.6 1.7 10.7 1.5 15 13 358 255 10.9 0 10.9 10.9 09/09/2005 19:20:00 8.6 1.8 14.1 5.3 8.4 1.9 14.1 5.3 6.3 2.1 11.8 2.3 17 12 12 255 10.7 0 10.9 10.6 09/09/2005 19:30:00 9.6 1.9 14.5 4.2 9.6 1.9 14.9 4.6 7.5 2.3 13.7 1.5 17 10 12 255 10.7 0 10.9 10.6 09/09/2005 19:40:00 9 1.5 16.1 5.7 8.9 1.5 16.4 5.3 7.1 1.9 14.5 3 18 13 29 255 10.7 0 10.9 10.6 09/09/2005 19:50:00 8.9 1.8 13.7 3.8 8.8 1.9 13.7 4.2 7 2.1 12.6 2.3 17 11 29 255 10.7 0 10.9 10.6 09/09/2005 20:00:00 10.2 2 14.5 6.1 10.2 2.1 14.9 6.1 8.1 2.2 13.3 3.4 17 11 39 255 10.8 0 11.1 10.6 09/09/2005 20:10:00 9.3 1.7 13.3 4.9 9.2 1.8 13.7 5.3 7.4 1.8 11.8 3.4 21 11 16 255 10.8 0 10.9 10.6 09/09/2005 20:20:00 6.7 1.7 11.5 2.3 6.5 1.7 11.5 2.3 5.4 1.5 11.1 2.6 41 17 26 255 10.9 0 11.1 10.9 09/09/2005 20:30:00 6 1.4 10.7 3 5.8 1.5 10.3 2.6 4.6 1.3 9.1 1.9 48 20 18 255 11 0 11.1 10.9 09/09/2005 20:40:00 5.1 1.3 9.1 2.6 4.9 1.4 8.8 2.3 3.8 1.5 8 0.4 68 17 90 255 10.9 0.1 11.1 10.6 09/09/2005 20:50:00 6.3 1.7 11.8 1.9 6.1 1.8 11.8 1.9 5.1 1.6 9.9 1.1 61 17 37 255 10.9 0 11.1 10.9 09/09/2005 21:00:00 5 1.2 8.8 2.3 4.8 1.3 8.8 1.9 4 1.3 8 1.1 67 17 46 255 11 0 11.1 10.9 09/09/2005 21:10:00 5.6 1.6 10.7 2.6 5.5 1.7 10.7 2.6 4.3 1.5 9.5 1.5 73 18 64 255 11.1 0 11.1 10.9 09/09/2005 21:20:00 6.2 1.2 9.5 3 6 1.3 9.5 2.6 4.8 1.3 9.1 1.9 58 17 76 255 11.1 0 11.1 11.1 09/09/2005 21:30:00 5.8 1.3 9.5 3 5.6 1.3 9.5 3 4.5 1.3 8.4 1.9 60 15 34 255 11 0 11.1 10.9 09/09/2005 21:40:00 5.3 1.4 8.8 1.9 5 1.5 8.8 1.5 3.8 1.4 8.4 0.7 70 15 77 255 10.9 0 11.1 10.9 09/09/2005 21:50:00 4.3 1.3 8.8 2.3 4.1 1.4 8.8 1.5 3 1.5 6.8 0.4 86 17 86 255 10.9 0 11.1 10.6 09/09/2005 22:00:00 5.8 1.3 8.8 2.6 5.7 1.3 8.8 2.3 4.6 1.5 8.4 1.5 73 15 69 255 10.7 0 10.9 10.6 09/09/2005 22:10:00 6.6 1.2 9.1 3.4 6.5 1.3 9.1 3.4 5.4 1.2 8.8 1.9 70 11 72 255 10.7 0 10.9 10.6 09/09/2005 22:20:00 6.2 1.2 9.5 3 6.1 1.2 9.1 2.6 4.8 1.2 8 2.3 61 17 73 255 10.7 0 10.9 10.6 09/09/2005 22:30:00 6.1 1.2 9.5 3.4 6 1.2 9.1 3.4 5 1.4 9.5 1.9 65 15 60 255 10.7 0 10.9 10.6 09/09/2005 22:40:00 6.7 1.5 10.3 3.4 6.6 1.5 9.9 3 5.3 1.5 9.1 1.9 57 15 42 255 10.7 0 10.9 10.6 09/09/2005 22:50:00 6.8 1.4 10.3 3.4 6.6 1.5 10.7 2.6 5.4 1.3 8.8 1.9 56 14 64 255 10.9 0 11.1 10.9 09/09/2005 23:00:00 5.6 1.3 9.9 2.6 5.4 1.3 9.1 1.1 4.4 1.3 7.6 1.1 68 17 100 255 10.9 0 11.1 10.9 09/09/2005 23:10:00 6 1.5 9.9 2.6 5.8 1.5 10.3 2.3 4.9 1.5 9.5 0.7 70 16 81 255 10.9 0 11.1 10.9 09/09/2005 23:20:00 5.8 1.3 9.5 2.3 5.6 1.3 8.8 2.3 4.6 1.3 8.8 1.5 66 16 52 255 11.1 0 11.1 10.9 09/09/2005 23:30:00 5.1 1.2 8.4 1.9 4.9 1.3 8.4 1.5 3.9 1.3 6.5 0.7 73 17 76 255 11.1 0 11.1 10.9 09/09/2005 23:40:00 4.6 1.1 7.6 1.9 4.3 1.1 7.6 1.9 3.4 1.3 7.6 0.4 72 18 62 255 10.8 0 11.1 10.6 09/09/2005 23:50:00 5.5 1.3 8.8 2.6 5.3 1.3 8.8 2.3 4.2 1.5 8.4 0.7 63 17 60 255 10.8 0 11.1 10.6 09/10/2005 00:00:00 5.5 1.3 9.1 2.6 5.4 1.4 9.9 2.6 4.5 1.3 8 1.1 74 16 66 255 11.2 0 11.4 11.1 09/10/2005 00:10:00 5 1 7.6 2.3 4.8 1.1 7.2 1.5 3.9 1.2 6.8 0.7 69 14 85 255 11.3 0 11.4 11.1 09/10/2005 00:20:00 5.8 1.2 8.4 3 5.6 1.2 8.8 2.6 4.5 1.5 8.4 0.7 68 17 54 255 11.3 0 11.4 11.1 09/10/2005 00:30:00 6 1.2 9.9 3.8 5.9 1.2 9.9 3.4 4.7 1.2 8.4 2.3 68 15 66 255 11.3 0 11.4 11.1 09/10/2005 00:40:00 5.8 1.4 9.1 2.3 5.6 1.5 9.1 1.5 4.4 1.3 8 1.1 65 16 66 255 11.3 0 11.4 11.1 09/10/2005 00:50:00 6.4 1.2 9.9 3.8 6.3 1.3 9.1 3 4.7 1.2 8 1.9 55 18 52 255 11.3 0 11.4 11.4 09/10/2005 01:00:00 4.5 1 7.2 1.9 4.3 1 7.2 1.5 3.3 0.9 5.7 1.5 64 15 53 255 11.3 0 11.4 11.4 09/10/2005 01:10:00 4.7 0.9 6.5 2.3 4.4 1 6.5 2.3 3.6 1 6.1 1.1 71 12 68 255 11.3 0 11.4 11.4 09/10/2005 01:20:00 3.7 0.9 5.7 1.5 3.4 0.9 5.7 1.1 2.4 0.9 4.2 0.4 87 15 93 255 11.3 0 11.4 11.4 09/10/2005 01:30:00 3.4 1 6.1 1.1 3.2 1 6.1 0.4 2 0.9 4.2 0.4 109 16 86 255 11.5 0 11.7 11.4 09/10/2005 01:40:00 4.2 1.1 7.6 1.5 4.1 1.1 7.6 1.5 3 1 6.1 0.7 79 14 52 255 11.5 0 11.7 11.4 09/10/2005 01:50:00 4.2 1.1 7.2 2.3 4 1.2 7.6 1.9 2.8 1.2 6.5 0.4 63 15 64 255 11.6 0 11.7 11.4 09/10/2005 02:00:00 4.7 1.1 7.6 1.5 4.6 1.2 7.2 1.1 3.6 1.2 7.2 0.7 64 15 48 255 11.6 0 11.7 11.7 09/10/2005 02:10:00 5.7 1.1 8 2.6 5.5 1.2 8 2.6 4 1.3 7.6 0.7 73 13 90 255 11.4 0.1 11.7 11.1 09/10/2005 02:20:00 5.3 1.1 7.6 3 5.1 1.2 7.6 2.6 3.8 1.3 7.2 1.1 79 16 63 255 11.4 0 11.7 11.4 09/10/2005 02:30:00 4.5 0.9 7.2 2.6 4.2 1 7.2 2.3 3.1 1.1 6.5 0.7 83 16 77 255 11.3 0 11.4 11.1 09/10/2005 02:40:00 4.5 0.7 6.5 2.3 4.3 0.7 6.1 2.3 3.2 1 5.7 1.1 90 13 85 255 11.3 0 11.4 11.1 09/10/2005 02:50:00 3.9 0.7 5.7 2.3 3.7 0.8 6.1 1.9 2.7 0.8 4.6 0.7 99 12 99 255 11.3 0 11.7 11.1 09/10/2005 03:00:00 4.2 0.7 6.5 2.6 4 0.7 5.7 1.9 3 0.9 6.1 0.4 95 11 90 255 11.5 0 11.7 11.4 09/10/2005 03:10:00 4.4 0.6 6.1 2.6 4.2 0.7 5.7 1.5 3 0.9 4.9 0.7 99 11 87 255 11.7 0 11.7 11.7 09/10/2005 03:20:00 4 0.7 6.1 2.3 3.7 0.7 5.7 2.3 2.7 0.9 4.9 0.7 95 12 88 255 11.7 0 11.7 11.7 09/10/2005 03:30:00 3.6 0.8 5.3 1.5 3.2 0.8 4.9 1.1 2.2 0.9 4.6 0.4 88 16 80 255 11.7 0 11.9 11.7 09/10/2005 03:40:00 3.7 0.7 5.3 1.9 3.5 0.7 5.3 1.9 2.4 0.9 4.2 0.4 83 13 83 255 11.7 0 11.7 11.7 09/10/2005 03:50:00 3.4 0.6 5.3 2.3 3.2 0.7 5.3 1.9 2.1 0.8 4.2 0.4 68 13 66 255 11.5 0 11.7 11.4 09/10/2005 04:00:00 2.9 0.5 4.6 1.9 2.7 0.6 4.2 1.5 1.6 0.6 3 0.4 58 11 70 255 11.3 0 11.7 11.4 09/10/2005 04:10:00 3.1 0.7 4.9 1.1 2.8 0.8 4.9 0.7 1.8 0.7 3.8 0.4 59 11 51 255 11.2 0 11.4 11.1 09/10/2005 04:20:00 3.1 0.6 5.3 1.5 2.8 0.7 4.9 0.7 1.9 0.8 4.2 0.4 40 13 44 255 11.1 0 11.4 11.1 09/10/2005 04:30:00 2.4 0.6 3.8 0.7 2.1 0.8 4.2 0.4 1.4 0.7 3.4 0.4 53 13 42 255 11.1 0 11.1 10.9 09/10/2005 04:40:00 2.7 0.6 4.2 1.5 2.4 0.6 4.2 1.1 1.5 0.6 3 0.4 42 9 40 255 10.9 0 11.1 10.9 09/10/2005 04:50:00 1.8 0.6 3 0.4 1.4 0.7 3 0.4 0.7 0.5 2.3 0.4 53 17 39 255 10.9 0 11.1 10.9 09/10/2005 05:00:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 47 51 326 255 10.6 0 10.9 10.6 09/10/2005 05:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 339 0 340 255 10.6 0 10.6 10.6 09/10/2005 05:20:00 0.9 0.6 3 0.4 0.6 0.6 3 0.4 0.4 0.3 2.3 0.4 23 43 42 255 10.5 0 10.6 10.6 09/10/2005 05:30:00 1.1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 52 13 44 255 10.5 0 10.6 10.3 09/10/2005 05:40:00 1.8 0.3 2.3 1.1 1.4 0.4 1.9 0.4 0.6 0.4 1.9 0.4 19 10 32 255 10.4 0 10.6 10.3 09/10/2005 05:50:00 1.5 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 29 5 25 255 10.2 0 10.6 10.1 09/10/2005 06:00:00 0.9 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 57 18 54 255 10.2 0 10.3 10.1 09/10/2005 06:10:00 1.1 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.5 0.4 70 8 74 255 10.1 0 10.3 10.1 09/10/2005 06:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 69 255 10.2 0 10.3 10.1 09/10/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 255 255 10.2 0 10.3 10.1 09/10/2005 06:40:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 69 255 10.2 0 10.3 10.1 09/10/2005 06:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 69 255 10.2 0 10.3 10.1 09/10/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 255 255 10.2 0 10.3 10.3 09/10/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 255 255 10.3 0 10.6 10.3 09/10/2005 07:20:00 0.9 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 18 106 255 10.4 0 10.6 10.3 09/10/2005 07:30:00 1.1 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 149 0 148 255 10.5 0 10.6 10.3 09/10/2005 07:40:00 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 132 9 136 255 10.5 0 10.6 10.6 09/10/2005 07:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 11 118 255 10.6 0 10.6 10.6 09/10/2005 08:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 123 27 147 255 10.6 0 10.9 10.6 09/10/2005 08:10:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 0 147 255 10.7 0 10.9 10.6 09/10/2005 08:20:00 0.9 0.5 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 143 15 134 255 10.9 0 11.1 10.9 09/10/2005 08:30:00 0.7 0.4 2.6 0.4 0.4 0.2 2.3 0.4 0.4 0.2 1.5 0.4 170 21 156 255 11.1 0 11.1 10.9 09/10/2005 08:40:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.5 0.4 194 58 310 255 11.2 0 11.4 11.1 09/10/2005 08:50:00 0.9 0.5 3 0.4 0.4 0.3 2.6 0.4 0.4 0.1 1.1 0.4 153 24 253 255 11.4 0 11.7 11.1 09/10/2005 09:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 183 14 206 255 11.6 0 11.7 11.4 09/10/2005 09:10:00 1.8 0.7 5.3 0.4 1.3 0.8 5.3 0.4 0.8 0.7 3.8 0.4 235 26 218 255 11.7 0 11.9 11.7 09/10/2005 09:20:00 1.5 0.6 3.4 0.4 1 0.7 3.4 0.4 0.7 0.5 2.6 0.4 240 22 218 255 12 0 12.2 11.9 09/10/2005 09:30:00 1.5 0.7 3.4 0.4 1 0.7 3.8 0.4 0.7 0.5 2.3 0.4 253 39 255 255 12.3 0 12.5 12.2 09/10/2005 09:40:00 2.4 0.8 4.9 0.7 2.1 0.9 4.2 0.4 1.3 0.9 4.6 0.4 250 22 246 255 12.5 0 12.7 12.5 09/10/2005 09:50:00 2.4 1 4.9 0.4 2 1 4.2 0.4 1.4 0.9 3.8 0.4 236 20 232 255 12.7 0 12.7 12.5 09/10/2005 10:00:00 2.5 0.9 4.9 0.7 2.1 1 4.9 0.4 1.4 0.9 3.8 0.4 224 23 206 255 13.1 0 13.3 12.7 09/10/2005 10:10:00 2.8 1 6.5 0.7 2.5 1.1 5.7 0.4 1.7 1 4.9 0.4 225 15 208 255 13.5 0 13.8 13.3 09/10/2005 10:20:00 3.1 1.1 6.1 0.7 2.8 1.2 6.1 0.4 1.9 1.2 5.3 0.4 235 23 253 255 13.5 0 13.5 13.3 09/10/2005 10:30:00 2.5 1 4.9 0.4 2.2 1 4.6 0.4 1.2 1 4.6 0.4 240 19 249 255 13.5 0 13.5 13.5 09/10/2005 10:40:00 1.9 1 4.6 0.4 1.6 1.1 4.6 0.4 0.9 0.8 3.4 0.4 258 23 247 255 13.5 0 13.5 13.5 09/10/2005 10:50:00 1.3 0.6 3 0.4 0.9 0.5 2.6 0.4 0.6 0.4 1.9 0.4 279 26 260 255 13.7 0 13.8 13.5 09/10/2005 11:00:00 1.3 0.8 3.8 0.4 1.1 0.7 3.8 0.4 0.5 0.3 1.9 0.4 282 35 266 255 14 0 14.1 13.8 09/10/2005 11:10:00 2.1 1 4.6 0.4 1.8 1.1 4.6 0.4 1.2 1 4.6 0.4 268 22 273 255 14.2 0 14.4 14.1 09/10/2005 11:20:00 2.4 1 4.6 0.4 2.2 1 4.6 0.4 1.4 1 4.2 0.4 264 18 259 255 14.1 0 14.4 14.1 09/10/2005 11:30:00 2.1 1 4.2 0.4 1.9 1.1 4.2 0.4 1.2 0.9 3.8 0.4 262 18 269 255 14.2 0 14.6 14.1 09/10/2005 11:40:00 2.1 1 4.6 0.4 1.8 1 4.2 0.4 1.2 0.9 3.4 0.4 255 27 241 255 14.2 0 14.9 14.4 09/10/2005 11:50:00 2.9 1.2 5.7 0.4 2.7 1.3 6.1 0.4 1.8 1.2 5.3 0.4 259 23 253 255 14.4 0 14.9 14.4 09/10/2005 12:00:00 2.6 1.1 5.7 0.4 2.5 1.1 5.7 0.4 1.9 1.1 5.3 0.4 267 23 276 255 14.3 0 14.9 14.4 09/10/2005 12:10:00 2.5 1.3 5.7 0.4 2.3 1.4 5.7 0.4 1.6 1.1 4.6 0.4 252 26 255 255 14.3 0 14.9 14.4 09/10/2005 12:20:00 3.3 1.5 7.6 0.7 3.1 1.5 7.2 0.4 2.3 1.5 6.1 0.4 257 19 253 255 14.5 0 14.9 14.4 09/10/2005 12:30:00 2.4 1.4 6.5 0.4 2.3 1.5 6.8 0.4 1.7 1.3 6.1 0.4 289 49 211 255 15.2 0.5 16.3 14.6 09/10/2005 12:40:00 2.5 1 4.9 0.4 2.3 1 4.9 0.4 1.6 1.1 4.2 0.4 260 35 273 255 15.7 0 16.3 15.5 09/10/2005 12:50:00 2.3 0.7 4.6 0.7 1.9 0.9 3.8 0.4 1.6 0.8 3.4 0.4 291 17 301 255 15.2 0.2 16 15.2 09/10/2005 13:00:00 2.4 0.9 4.6 0.4 2.1 1 4.6 0.4 1.8 1 4.6 0.4 292 16 289 255 15.1 0 15.5 14.9 09/10/2005 13:10:00 2 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1 0.8 3.4 0.4 313 28 295 255 15.5 0 16 15.2 09/10/2005 13:20:00 1.7 0.8 3.8 0.4 1.3 0.8 3 0.4 0.9 0.7 3 0.4 329 32 309 255 15.6 0 16 15.5 09/10/2005 13:30:00 2.1 0.7 3.8 0.4 1.9 0.8 3.8 0.4 0.9 0.7 3.4 0.4 3 22 26 255 15.6 0 16 15.5 09/10/2005 13:40:00 1.8 0.8 3.4 0.4 1.5 0.8 3.4 0.4 0.9 0.7 2.6 0.4 359 24 10 255 15.3 0.1 16 15.2 09/10/2005 13:50:00 2.2 0.6 3.4 0.7 1.9 0.6 3 0.4 1.3 0.8 3.4 0.4 5 11 14 255 15.1 0.1 15.7 15.2 09/10/2005 14:00:00 2.7 0.5 3.4 1.1 2.5 0.5 3.4 0.7 1.9 0.8 3.4 0.4 22 10 21 255 15.1 0.1 15.7 14.9 09/10/2005 14:10:00 2.4 0.7 3.4 0.4 2.2 0.7 3.4 0.4 1.1 0.7 3 0.4 13 12 35 255 15.1 0.1 15.7 15.2 09/10/2005 14:20:00 2.9 0.4 3.8 1.9 2.7 0.5 3.8 1.5 2.1 0.6 3.4 0.4 17 7 17 255 15.2 0.1 15.7 15.2 09/10/2005 14:30:00 2.8 0.5 4.2 1.9 2.6 0.5 3.8 1.5 2.2 0.6 3.4 0.4 35 12 64 255 15 0 15.5 14.9 09/10/2005 14:40:00 2.8 0.5 3.8 1.1 2.6 0.5 3.8 0.7 1.9 0.7 3.4 0.4 27 15 5 255 15.7 0.3 16.3 15.2 09/10/2005 14:50:00 2.9 0.5 3.8 1.5 2.7 0.5 3.8 1.1 1.9 0.7 3.4 0.4 32 15 43 255 15.7 0 16.3 15.5 09/10/2005 15:00:00 2.4 0.5 3.8 0.7 2.1 0.6 3.4 0.4 1 0.7 2.6 0.4 5 17 3 255 15.7 0.1 16.3 15.7 09/10/2005 15:10:00 1.5 0.6 2.6 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 9 29 47 255 15.7 0.1 16.3 15.5 09/10/2005 15:20:00 1.9 0.4 3 1.1 1.5 0.4 2.3 0.4 0.8 0.6 2.6 0.4 15 10 32 255 15.4 0 15.7 15.5 09/10/2005 15:30:00 1.9 0.6 3 0.4 1.6 0.7 2.6 0.4 1 0.7 2.6 0.4 3 15 353 255 15.4 0 16 15.5 09/10/2005 15:40:00 2.5 0.5 3.4 0.7 2.2 0.6 3.4 0.4 1.3 0.8 3 0.4 6 17 10 255 15.6 0.2 16.3 15.5 09/10/2005 15:50:00 2.5 0.4 3.4 1.1 2.2 0.5 3.4 0.4 1.2 0.6 2.6 0.4 359 11 359 255 15.9 0 16.3 15.7 09/10/2005 16:00:00 2.9 0.5 3.8 1.5 2.6 0.6 3.8 1.1 1.1 0.6 3 0.4 357 12 359 255 15.7 0 16.3 15.5 09/10/2005 16:10:00 2.4 0.5 3.4 0.4 2.1 0.6 3.4 0.4 1.1 0.7 3 0.4 6 13 19 255 15.7 0 16.3 15.5 09/10/2005 16:20:00 2.4 0.7 3.8 0.4 2.1 0.8 3.4 0.4 1.1 0.8 3.4 0.4 3 17 2 255 16.1 0 16.6 16 09/10/2005 16:30:00 2.4 0.5 3.4 0.7 2.1 0.6 3.4 0.4 1.4 0.8 3.4 0.4 15 15 38 255 15.9 0.1 16.6 15.5 09/10/2005 16:40:00 2.1 0.6 3.4 0.4 1.7 0.6 3.4 0.4 0.9 0.6 2.3 0.4 1 12 6 255 15.2 0.2 15.7 14.9 09/10/2005 16:50:00 2.5 0.5 3.8 1.1 2.3 0.6 3.8 0.4 1.5 0.9 3.4 0.4 9 14 32 255 14.8 0.1 15.2 14.6 09/10/2005 17:00:00 2.7 0.8 4.6 1.1 2.4 1 4.2 0.4 1.7 1.1 4.2 0.4 14 17 25 255 14.6 0.2 15.2 14.6 09/10/2005 17:10:00 3.1 0.6 4.6 1.5 2.9 0.6 4.2 1.5 2.4 0.6 4.2 0.7 17 11 14 255 14.5 0.1 15.2 14.4 09/10/2005 17:20:00 3 0.5 4.2 1.5 2.8 0.5 3.8 1.5 2.2 0.8 3.4 0.4 17 8 17 255 14.2 0 14.6 13.8 09/10/2005 17:30:00 2.5 0.4 3.4 1.1 2.3 0.5 3.4 0.7 1.3 0.7 3 0.4 5 15 358 255 13.7 0 13.8 13.5 09/10/2005 17:40:00 2.9 0.5 4.2 1.5 2.6 0.6 3.8 0.7 1.8 0.8 3.4 0.4 10 15 21 255 13.4 0 13.8 13.3 09/10/2005 17:50:00 2.9 0.4 3.8 1.5 2.7 0.4 3.8 1.1 2 0.6 3.4 0.7 7 11 10 255 13.3 0 13.5 13 09/10/2005 18:00:00 2 0.6 3.4 0.7 1.9 0.6 3 0.4 1.2 0.7 2.6 0.4 12 8 4 255 13.1 0 13.5 13 09/10/2005 18:10:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.7 1.5 0.6 3 0.4 29 13 18 255 13.1 0 13.3 13 09/10/2005 18:20:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.1 2.1 0.6 3.4 0.4 27 9 26 255 13.2 0 13.3 13 09/10/2005 18:30:00 2.9 0.5 4.2 1.5 3 0.4 4.2 1.9 2.1 0.7 3.8 0.7 23 12 27 255 12.9 0 13.3 12.7 09/10/2005 18:40:00 2.5 0.5 3.4 1.1 2.5 0.4 3.4 1.1 1.9 0.6 3 0.4 40 18 33 255 12.8 0 13 12.7 09/10/2005 18:50:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 1.5 0.7 3.4 0.4 34 13 59 255 12.5 0.1 12.7 12.2 09/10/2005 19:00:00 2.6 0.6 3.8 0.7 2.5 0.6 4.2 0.7 1.9 0.8 3.8 0.4 42 12 39 255 12.5 0 12.7 12.5 09/10/2005 19:10:00 2.5 0.5 3.8 0.7 2.4 0.5 3.8 0.7 1.8 0.6 3.4 0.4 38 10 30 255 12.3 0 12.5 12.2 09/10/2005 19:20:00 1.8 0.5 3 0.4 1.7 0.5 3.4 0.4 0.8 0.5 2.3 0.4 45 12 26 255 11.9 0.2 12.2 11.4 09/10/2005 19:30:00 1.9 0.5 3.4 0.7 1.7 0.5 3.4 0.7 0.8 0.4 1.9 0.4 55 13 62 255 11.2 0 11.7 11.1 09/10/2005 19:40:00 1.9 0.5 3.4 0.7 1.8 0.5 3 0.7 0.7 0.5 2.3 0.4 56 12 35 255 10.8 0.1 11.1 10.6 09/10/2005 19:50:00 1.9 0.5 2.6 0.7 1.7 0.5 3 0.4 0.7 0.4 2.3 0.4 63 12 52 255 10.3 0.1 10.6 10.3 09/10/2005 20:00:00 2.1 0.4 3 1.1 2 0.5 3 0.4 1 0.5 2.3 0.4 62 11 63 255 10.1 0 10.3 10.1 09/10/2005 20:10:00 2.6 0.5 3.8 1.1 2.4 0.6 4.2 1.1 1.5 0.6 3 0.4 53 12 54 255 10 0 10.1 10.1 09/10/2005 20:20:00 2 0.5 3 0.4 1.9 0.6 3.4 0.4 0.9 0.5 2.6 0.4 55 13 60 255 10 0 10.3 9.8 09/10/2005 20:30:00 2.3 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.2 0.6 2.6 0.4 68 11 81 255 9.9 0.1 10.1 9.6 09/10/2005 20:40:00 2.4 0.5 3.8 1.5 2.3 0.5 3.8 1.1 1.2 0.6 3 0.4 60 13 57 255 9.6 0 9.8 9.6 09/10/2005 20:50:00 2.4 0.6 4.2 1.1 2.2 0.6 3.8 0.7 1.1 0.7 3 0.4 58 15 36 255 9.5 0 9.6 9.3 09/10/2005 21:00:00 2.3 0.4 3.8 1.1 2.1 0.5 3.4 1.1 0.9 0.6 3 0.4 69 12 95 255 9.4 0 9.6 9.3 09/10/2005 21:10:00 2.6 0.5 4.2 1.1 2.5 0.6 3.8 0.7 1.4 0.6 3.4 0.4 62 12 66 255 9.3 0 9.3 9.3 09/10/2005 21:20:00 3 0.7 4.6 0.7 2.9 0.8 4.6 1.1 2 0.8 4.2 0.4 56 16 61 255 9.3 0 9.6 9 09/10/2005 21:30:00 2.6 0.5 3.8 1.5 2.5 0.6 3.8 1.1 1.3 0.6 3 0.4 73 15 57 255 9.6 0 9.6 9.6 09/10/2005 21:40:00 3.2 0.8 5.7 1.5 3.1 0.8 5.3 1.1 1.9 0.9 4.6 0.4 83 12 78 255 9.4 0 9.6 9.3 09/10/2005 21:50:00 3.5 0.7 4.9 1.1 3.3 0.7 5.3 1.1 2.3 0.8 4.2 0.4 77 12 79 255 9.4 0 9.6 9.3 09/10/2005 22:00:00 3.8 0.6 5.3 2.6 3.7 0.6 5.3 2.3 2.5 0.8 4.9 0.4 79 11 76 255 9.6 0 9.8 9.6 09/10/2005 22:10:00 3.5 0.7 5.3 1.9 3.4 0.7 5.3 1.5 2.2 0.9 4.9 0.4 81 13 79 255 9.6 0 9.8 9.6 09/10/2005 22:20:00 4 0.7 5.7 2.6 3.9 0.7 5.7 2.3 2.6 0.8 4.6 0.4 78 11 60 255 9.8 0 10.1 9.6 09/10/2005 22:30:00 3.4 0.8 5.3 1.9 3.2 0.8 4.9 1.1 2.1 0.8 4.2 0.4 88 13 87 255 10.2 0 10.6 10.1 09/10/2005 22:40:00 3.4 0.6 4.6 2.3 3.2 0.6 4.6 1.5 2.2 0.6 3.8 0.4 91 10 81 255 10.5 0 10.6 10.3 09/10/2005 22:50:00 3 0.5 4.6 1.5 2.7 0.6 4.6 0.7 1.6 0.8 3.4 0.4 107 12 127 255 10.6 0 10.6 10.6 09/10/2005 23:00:00 3.4 0.7 4.9 1.1 3.1 0.7 4.6 0.7 2.1 0.7 3.8 0.4 111 13 116 255 10.5 0 10.6 10.6 09/10/2005 23:10:00 3.5 0.6 4.6 1.9 3.3 0.6 4.6 1.5 2.4 0.7 3.8 0.4 110 11 97 255 10.5 0 10.6 10.3 09/10/2005 23:20:00 3.4 0.6 4.6 1.9 3.2 0.6 4.6 1.5 2.2 0.8 3.8 0.4 109 13 118 255 10.4 0 10.6 10.3 09/10/2005 23:30:00 4 0.5 5.3 1.9 3.7 0.5 4.9 1.9 2.7 0.7 4.2 1.1 103 11 96 255 10.2 0 10.6 10.1 09/10/2005 23:40:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.5 2.3 0.8 4.6 0.7 103 11 102 255 10 0 10.3 9.8 09/10/2005 23:50:00 3 0.6 4.6 1.5 2.7 0.7 4.6 1.1 1.8 0.8 3.8 0.4 88 17 124 255 9.9 0 10.1 9.8 09/11/2005 00:00:00 3.3 0.6 4.6 1.9 3 0.6 4.6 1.5 1.8 0.7 3.4 0.4 100 12 91 255 9.5 0 10.3 9.3 09/11/2005 00:10:00 3 0.5 4.2 1.5 2.7 0.6 3.8 1.5 1.5 0.7 3.4 0.4 109 13 81 255 9.2 0 9.3 9 09/11/2005 00:20:00 2.4 0.7 4.2 1.1 2.1 0.8 3.8 0.4 1.1 0.6 2.6 0.4 115 15 107 255 9 0 9.3 9 09/11/2005 00:30:00 1.6 0.6 3.4 0.4 1 0.6 3 0.4 0.4 0.2 1.9 0.4 112 18 133 255 9 0 9 8.8 09/11/2005 00:40:00 2.5 0.5 3.8 1.1 2.1 0.5 3.4 0.4 1.1 0.5 2.6 0.4 105 8 111 255 8.7 0 9 8.8 09/11/2005 00:50:00 2.5 0.6 3.8 0.7 2.1 0.6 3.4 0.4 0.9 0.5 2.6 0.4 115 12 90 255 8.5 0.1 8.8 8.5 09/11/2005 01:00:00 2.6 0.5 3.8 1.5 2.3 0.5 3.8 1.1 1.1 0.6 3 0.4 113 12 112 255 8.6 0 8.8 8.5 09/11/2005 01:10:00 2.6 0.7 4.2 1.1 2.3 0.7 3.8 0.4 1.2 0.7 3 0.4 117 16 101 255 8.7 0 8.8 8.5 09/11/2005 01:20:00 2.8 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.2 0.7 2.6 0.4 107 14 111 255 8.9 0 9 8.8 09/11/2005 01:30:00 3.1 0.7 4.6 1.5 2.8 0.7 4.2 0.7 1.5 0.7 3 0.4 115 13 94 255 8.8 0 9 8.8 09/11/2005 01:40:00 3.3 0.7 4.9 1.1 3 0.7 4.6 1.1 1.8 0.8 3.8 0.4 112 15 101 255 9 0 9.3 9 09/11/2005 01:50:00 2.9 0.7 4.9 1.1 2.6 0.8 4.6 0.4 1.5 0.8 3.8 0.4 116 17 115 255 9.1 0 9.3 9 09/11/2005 02:00:00 2.2 0.6 3.8 0.7 1.8 0.7 3.4 0.4 0.9 0.7 3 0.4 100 16 127 255 9 0 9 9 09/11/2005 02:10:00 2.7 0.6 3.8 1.1 2.3 0.7 3.8 0.7 1.3 0.8 3 0.4 105 9 104 255 8.7 0.1 9 8.5 09/11/2005 02:20:00 3.6 0.4 4.6 2.6 3.4 0.4 4.6 2.3 2.3 0.6 3.8 0.4 104 9 100 255 8.7 0 8.8 8.5 09/11/2005 02:30:00 3.5 0.6 5.3 1.9 3.3 0.8 4.9 0.7 2.3 0.8 4.6 0.4 101 12 106 255 8.9 0 9 8.8 09/11/2005 02:40:00 3.3 0.6 5.3 1.5 3 0.7 4.9 0.7 2.2 0.7 3.8 0.4 104 11 109 255 9.1 0 9.3 9 09/11/2005 02:50:00 2.7 0.6 4.2 1.1 2.4 0.7 4.2 0.4 1.4 0.6 2.6 0.4 109 12 111 255 9 0 9.3 9 09/11/2005 03:00:00 3 0.5 4.2 1.5 2.6 0.6 3.8 1.1 1.7 0.6 3.4 0.4 112 11 112 255 9 0 9 9 09/11/2005 03:10:00 2.8 0.6 4.2 1.5 2.5 0.7 4.2 0.7 1.5 0.8 3.4 0.4 115 13 123 255 9.1 0 9.3 9 09/11/2005 03:20:00 2.4 0.6 3.8 0.7 1.9 0.7 3.8 0.4 1 0.6 2.6 0.4 118 13 111 255 9.2 0 9.3 9 09/11/2005 03:30:00 2.3 0.6 3.8 1.1 1.8 0.6 3.4 0.4 1 0.5 2.3 0.4 125 11 134 255 9.1 0 9.3 9 09/11/2005 03:40:00 2.3 0.5 3.8 1.5 2 0.5 3.4 0.7 1.2 0.7 3 0.4 128 12 134 255 9.1 0 9.3 9 09/11/2005 03:50:00 2.1 0.5 3.4 0.7 1.7 0.7 3 0.4 0.8 0.5 2.3 0.4 119 15 113 255 9 0 9.3 9 09/11/2005 04:00:00 3.2 0.8 5.3 0.7 2.8 0.8 4.9 0.4 1.8 0.8 4.6 0.4 113 12 115 255 8.9 0 9 8.8 09/11/2005 04:10:00 3.2 0.6 4.6 1.5 2.8 0.6 4.2 1.1 1.7 0.8 4.2 0.4 110 12 111 255 9.1 0 9.3 9 09/11/2005 04:20:00 2.8 0.6 4.2 1.5 2.4 0.7 3.8 0.7 1.5 0.7 3.4 0.4 114 13 97 255 9.3 0 9.3 9.3 09/11/2005 04:30:00 2.5 0.6 4.6 1.1 2.1 0.8 3.8 0.4 1.2 0.7 3 0.4 120 19 97 255 9.1 0 9.3 9 09/11/2005 04:40:00 2.6 0.8 4.2 0.7 2.2 0.8 4.2 0.4 1.3 0.7 3 0.4 113 15 104 255 9.1 0 9.3 9 09/11/2005 04:50:00 3.1 0.5 4.2 1.9 2.7 0.6 4.2 1.1 1.8 0.7 3.4 0.4 107 10 107 255 9 0 9.3 9 09/11/2005 05:00:00 3.5 0.6 4.9 1.9 3.2 0.5 4.6 1.5 2 0.7 3.8 0.4 106 12 104 255 9.1 0 9.3 9 09/11/2005 05:10:00 3.1 0.5 4.6 1.5 2.8 0.5 4.2 1.5 1.7 0.8 3.4 0.4 107 11 105 255 9.1 0 9.3 9 09/11/2005 05:20:00 2.9 0.3 3.8 1.9 2.7 0.3 3.4 1.9 1.4 0.5 2.6 0.4 102 8 100 255 8.9 0 9.3 8.8 09/11/2005 05:30:00 2.5 0.4 3.4 1.5 2.2 0.4 3.4 0.7 0.8 0.5 2.3 0.4 98 9 80 255 8.5 0 8.8 8.3 09/11/2005 05:40:00 2.2 0.5 3.4 0.7 1.8 0.6 3 0.4 0.8 0.5 2.3 0.4 106 14 116 255 8.2 0 8.5 8 09/11/2005 05:50:00 2.5 0.5 3.8 1.1 2.1 0.5 3.4 0.7 0.8 0.6 2.6 0.4 107 11 99 255 7.8 0 8.3 7.5 09/11/2005 06:00:00 3.5 0.5 4.6 1.9 3.2 0.6 4.6 1.5 2 0.7 3.8 0.4 104 9 102 255 7.8 0 7.8 7.5 09/11/2005 06:10:00 3.1 0.6 4.9 1.5 2.8 0.7 4.6 0.7 1.7 0.8 3.4 0.4 108 15 126 255 7.8 0 7.8 7.8 09/11/2005 06:20:00 3.3 0.5 4.2 2.3 3 0.5 4.2 1.5 1.8 0.7 3.4 0.4 107 11 102 255 7.7 0 7.8 7.5 09/11/2005 06:30:00 3.7 0.6 4.9 2.3 3.4 0.6 4.9 1.5 2.1 0.7 3.8 0.4 110 12 103 255 7.7 0 7.8 7.5 09/11/2005 06:40:00 3.6 0.6 4.9 1.9 3.3 0.6 4.9 1.5 2.1 0.7 3.8 0.4 108 13 102 255 7.9 0 8.3 7.5 09/11/2005 06:50:00 3.1 0.6 4.6 1.1 2.8 0.7 4.2 0.7 1.7 0.8 3.4 0.4 105 12 105 255 8.2 0 8.3 8.3 09/11/2005 07:00:00 2.3 0.6 4.2 1.1 1.8 0.8 3.8 0.4 0.9 0.7 3.4 0.4 114 17 109 255 8.2 0 8.5 8.3 09/11/2005 07:10:00 3.6 0.6 4.9 1.5 3.3 0.7 4.9 0.7 2.2 0.7 4.2 0.4 104 11 99 255 8.6 0.2 9.3 8.3 09/11/2005 07:20:00 2.7 0.8 4.6 0.7 2.2 0.9 4.2 0.4 1.4 0.9 3.8 0.4 110 15 100 255 9.9 0.3 10.3 9.3 09/11/2005 07:30:00 2.3 0.5 4.2 1.1 1.9 0.7 3.8 0.4 1.1 0.6 2.6 0.4 123 16 106 255 10.4 0 10.6 10.3 09/11/2005 07:40:00 2.6 0.9 4.6 0.7 2.2 1 4.6 0.4 1.3 0.9 3.4 0.4 110 19 108 255 10.6 0 10.9 10.6 09/11/2005 07:50:00 2.5 1 4.6 0.4 2.1 1.1 4.2 0.4 1.5 1.1 4.2 0.4 89 14 89 255 11.2 0.3 11.7 10.6 09/11/2005 08:00:00 2.5 0.6 4.2 1.1 2.1 0.8 4.2 0.4 1.4 0.8 3.4 0.4 75 15 83 255 12.1 0.2 12.5 11.7 09/11/2005 08:10:00 2.7 0.6 4.6 1.1 2.4 0.7 4.6 0.7 1.8 0.7 3.8 0.4 76 17 95 255 12.3 0 12.5 12.2 09/11/2005 08:20:00 2.8 0.7 4.6 1.1 2.4 0.9 4.2 0.4 2 0.7 3.8 0.4 86 12 74 255 12.3 0 12.5 12.2 09/11/2005 08:30:00 2.4 0.6 3.8 1.1 2.1 0.7 3.4 0.4 1.6 0.8 3.4 0.4 82 11 79 255 11.9 0.2 12.2 11.7 09/11/2005 08:40:00 2.2 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.7 3 0.4 97 12 92 255 12.9 0.4 13.5 11.9 09/11/2005 08:50:00 2.5 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 106 12 96 255 13.7 0.1 13.8 13.3 09/11/2005 09:00:00 2.4 0.7 3.4 0.4 2 0.7 3.4 0.4 1.7 0.7 3.4 0.4 108 12 104 255 13.1 0.2 13.3 12.7 09/11/2005 09:10:00 1.1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 132 22 131 255 12.7 0 12.7 12.5 09/11/2005 09:20:00 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 109 38 93 255 13.5 0.4 14.4 12.7 09/11/2005 09:30:00 1.4 0.7 3 0.4 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 63 32 69 255 14.8 0.3 15.7 14.1 09/11/2005 09:40:00 2.1 0.7 3.4 0.7 1.7 0.8 3.4 0.4 1.4 0.8 3 0.4 52 21 69 255 15.5 0.2 16.3 15.2 09/11/2005 09:50:00 1.3 0.7 3 0.4 1 0.7 3 0.4 0.9 0.8 4.2 0.4 47 38 110 255 16.3 0.1 16.8 16 09/11/2005 10:00:00 1.9 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1.2 0.7 3 0.4 19 15 11 255 16.1 0.1 16.8 15.7 09/11/2005 10:10:00 2.8 0.5 4.2 1.5 2.6 0.6 4.2 1.1 2 0.7 4.2 0.4 29 16 37 255 16.8 0.2 17.4 16.3 09/11/2005 10:20:00 2.5 0.5 4.2 1.1 2.3 0.6 3.8 0.7 1.8 0.7 3 0.4 38 21 23 255 15.8 0.3 16.6 15.2 09/11/2005 10:30:00 2 0.5 3.8 0.7 1.7 0.5 3.4 0.4 1.2 0.5 2.6 0.4 13 17 356 255 15.4 0 15.7 15.2 09/11/2005 10:40:00 1.9 0.5 3 0.4 1.4 0.5 2.6 0.4 1 0.6 2.6 0.4 2 21 343 255 15.7 0 16 15.5 09/11/2005 10:50:00 1.6 0.6 2.6 0.4 1.1 0.5 2.6 0.4 0.8 0.5 2.6 0.4 316 21 347 255 15.2 0.2 15.7 15.2 09/11/2005 11:00:00 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 1 0.6 2.3 0.4 359 21 29 255 15 0 15.5 15.2 09/11/2005 11:10:00 1.8 0.4 3.4 0.4 1.5 0.5 3 0.4 1.1 0.6 3 0.4 20 15 18 255 15.4 0.3 16.3 15.2 09/11/2005 11:20:00 2.8 0.9 4.9 0.7 2.6 1 4.9 0.4 2.1 1 4.2 0.4 35 19 49 255 16.2 0.1 16.8 16 09/11/2005 11:30:00 2.6 1 4.6 0.7 2.3 1.1 4.6 0.4 2 1 4.2 0.4 16 17 21 255 17.1 0.2 17.4 16.6 09/11/2005 11:40:00 2.8 0.8 4.6 1.1 2.6 0.9 4.6 0.4 2.1 1 4.2 0.4 15 22 26 255 17.7 0 18.2 17.4 09/11/2005 11:50:00 2.6 0.7 4.6 0.7 2.3 0.8 4.6 0.4 2.1 0.8 4.2 0.4 22 26 14 255 17.4 0.2 18 17.1 09/11/2005 12:00:00 3.2 0.7 4.9 1.5 2.9 0.8 4.9 1.1 2.4 0.8 4.9 0.7 20 18 2 255 17.3 0 17.4 17.1 09/11/2005 12:10:00 4 1 6.5 1.9 3.9 1 6.1 1.5 3.4 1 6.1 0.4 31 19 56 255 17.3 0 17.4 17.1 09/11/2005 12:20:00 3.6 1.3 6.1 1.1 3.5 1.3 6.1 0.4 3 1.4 6.1 0.4 42 28 55 255 17.5 0 17.7 17.1 09/11/2005 12:30:00 2.4 0.8 4.2 0.4 2 0.8 3.8 0.4 1.8 0.8 3.8 0.4 325 43 337 255 18.2 0.3 18.8 17.4 09/11/2005 12:40:00 2.2 0.8 4.2 0.4 2 0.8 3.8 0.4 1.6 0.8 3.8 0.4 324 33 301 255 18.7 0 18.8 18.5 09/11/2005 12:50:00 2.2 1 4.6 0.4 1.8 1.1 4.6 0.4 1.5 0.9 3.4 0.4 344 32 5 255 18.4 0 18.8 18 09/11/2005 13:00:00 2.6 0.9 5.7 0.7 2.2 1 4.9 0.4 2 0.9 5.3 0.4 0 29 335 255 18.2 0.1 18.5 18 09/11/2005 13:10:00 3.5 0.9 5.7 1.9 3.3 1 5.7 0.7 2.9 1.1 5.7 0.4 23 23 37 255 18.5 0 18.8 18.2 09/11/2005 13:20:00 3.2 0.8 5.3 1.1 3.1 0.9 4.9 0.4 2.5 1 4.9 0.4 16 24 19 255 19 0.1 19.4 18.5 09/11/2005 13:30:00 2.2 0.8 4.9 0.4 2 0.9 4.6 0.4 1.5 0.8 3.8 0.4 3 18 351 255 19.4 0 19.7 19.4 09/11/2005 13:40:00 3 0.7 4.9 1.1 2.8 0.7 4.9 1.1 2 1 4.9 0.4 1 20 345 255 19.1 0 19.4 18.8 09/11/2005 13:50:00 2.1 0.5 3.4 0.4 1.8 0.6 3 0.4 1.6 0.7 3.8 0.4 341 30 349 255 19.2 0.2 20 18.8 09/11/2005 14:00:00 2.3 0.7 3.8 0.7 2 0.8 3.8 0.4 1.6 0.7 3.4 0.4 357 17 20 255 19.5 0.1 20.3 19.4 09/11/2005 14:10:00 2.1 0.9 4.6 0.7 1.9 1 4.6 0.4 1.8 0.8 4.2 0.4 8 18 348 255 19.7 0.1 20.3 19.4 09/11/2005 14:20:00 2.9 0.9 4.9 0.4 2.7 1 4.9 0.4 2.2 1 4.6 0.4 25 28 10 255 20.2 0 20.5 20 09/11/2005 14:30:00 2.5 0.6 4.6 1.1 2.2 0.7 4.6 0.4 2 0.6 4.2 0.7 355 30 318 255 20.3 0.2 20.5 19.7 09/11/2005 14:40:00 1.9 1 4.2 0.4 1.6 1 4.2 0.4 1.2 1 4.6 0.4 13 24 31 255 20.2 0.2 20.5 19.7 09/11/2005 14:50:00 2.6 0.7 4.2 1.1 2.5 0.7 4.2 1.1 2 0.8 3.8 0.4 18 17 19 255 19.8 0.2 20.5 19.4 09/11/2005 15:00:00 2 0.6 3.4 0.7 1.8 0.7 3 0.4 1.2 0.7 3 0.4 352 27 10 255 19 0 19.4 18.8 09/11/2005 15:10:00 1.7 0.6 3.4 0.4 1.2 0.6 3.4 0.4 1 0.7 3 0.4 349 30 347 255 18.7 0.2 19.1 18.2 09/11/2005 15:20:00 1.6 0.7 3 0.4 1.3 0.7 2.6 0.4 1 0.6 2.6 0.4 336 29 339 255 18.5 0.1 18.8 18.2 09/11/2005 15:30:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 344 36 306 255 18.7 0 19.4 18.5 09/11/2005 15:40:00 1.1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 339 36 286 255 18.4 0.2 19.4 18 09/11/2005 15:50:00 1.4 0.5 2.6 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 336 14 342 255 18 0 18.5 17.7 09/11/2005 16:00:00 1.9 0.4 3 0.7 1.4 0.5 2.6 0.4 1 0.5 2.6 0.4 353 22 324 255 17.9 0.1 18.5 17.7 09/11/2005 16:10:00 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 12 13 10 255 18.4 0 18.5 18.2 09/11/2005 16:20:00 1.7 0.8 3 0.4 1.5 0.7 3 0.4 1.4 0.7 2.6 0.4 27 24 47 255 18.7 0 18.8 18.5 09/11/2005 16:30:00 3.4 1 5.3 1.1 3.3 1.1 5.3 1.1 2.7 0.9 4.9 1.1 35 13 32 255 18 0.2 18.5 17.4 09/11/2005 16:40:00 2.8 0.7 4.6 1.1 2.7 0.7 4.6 1.1 2.2 0.8 4.2 0.4 39 16 32 255 17.3 0 17.4 17.1 09/11/2005 16:50:00 3 0.8 5.3 1.5 2.9 0.8 5.7 1.5 2.1 0.8 4.2 0.4 23 17 13 255 17.2 0 17.1 16.8 09/11/2005 17:00:00 2.7 0.9 4.6 1.1 2.6 1 4.6 0.7 1.5 1 4.2 0.4 11 14 16 255 16.8 0 17.1 16.8 09/11/2005 17:10:00 2 0.8 4.9 0.4 1.8 0.8 4.9 0.4 0.9 0.8 3.8 0.4 11 21 28 255 16.6 0.1 16.8 16.3 09/11/2005 17:20:00 2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.1 0.7 2.6 0.4 18 10 17 255 16.1 0 16.8 16 09/11/2005 17:30:00 1.9 0.6 3.8 0.7 1.6 0.7 3.4 0.4 0.8 0.5 3 0.4 1 10 17 255 15.8 0.1 16.3 15.7 09/11/2005 17:40:00 3.4 0.7 5.3 1.9 3.2 0.8 4.9 1.5 1.9 0.9 4.6 0.4 9 11 16 255 15.7 0 16.3 15.7 09/11/2005 17:50:00 3.5 0.7 4.9 1.1 3.4 0.7 4.9 1.5 2.6 0.8 4.6 0.4 25 12 9 255 16.1 0.1 16.8 15.7 09/11/2005 18:00:00 2.4 0.5 4.2 1.1 2.2 0.5 3.8 0.7 1.8 0.6 3.8 0.4 58 19 66 255 16.2 0.1 16.8 16 09/11/2005 18:10:00 2.9 0.8 5.3 1.5 2.6 0.9 4.9 0.7 2 0.7 4.2 0.4 48 14 51 255 16 0 16.6 15.7 09/11/2005 18:20:00 3.2 0.6 4.9 1.9 3 0.7 4.9 1.5 2 0.8 4.9 0.7 15 11 357 255 15.5 0.2 16.3 15.2 09/11/2005 18:30:00 4 1.5 8.8 1.1 3.9 1.5 8.4 1.1 2.9 1.6 7.6 0.4 11 16 21 255 14.9 0 15.7 14.6 09/11/2005 18:40:00 4.9 1.1 9.1 2.3 4.8 1.2 9.1 1.5 3.4 1.2 6.5 0.7 13 17 52 255 14.6 0 15.2 14.4 09/11/2005 18:50:00 6.2 1.1 8.8 2.6 6.2 1.1 8.8 2.3 4.5 1.3 7.2 0.7 12 12 10 255 14.4 0 14.6 14.4 09/11/2005 19:00:00 5.4 1.4 8.4 2.3 5.4 1.4 8.4 2.3 4.1 1.3 7.2 0.7 25 19 2 255 14.6 0 15.2 14.6 09/11/2005 19:10:00 7.9 2.3 13.7 2.6 7.8 2.3 13.3 2.6 6.3 2.1 11.8 1.9 26 15 18 255 15 0.1 15.7 14.9 09/11/2005 19:20:00 7.9 1.7 13.3 3.8 7.8 1.6 13.3 3.8 6.2 1.7 11.1 2.3 19 13 14 255 15.2 0 15.7 15.2 09/11/2005 19:30:00 5.3 1.5 9.1 1.9 5.1 1.5 8.8 1.5 4.4 1.4 7.6 1.1 45 17 43 255 15 0 15.5 14.9 09/11/2005 19:40:00 5.4 1.1 8.8 2.3 5.3 1.1 8.4 1.9 4.4 1 7.2 2.3 48 16 31 255 14.7 0.1 15.5 14.6 09/11/2005 19:50:00 6.1 1.7 11.5 3 6.1 1.7 10.7 3 4.9 1.7 9.5 1.5 46 16 44 255 14.5 0 14.9 14.4 09/11/2005 20:00:00 6.9 1.5 10.3 3 6.8 1.5 10.3 3 5.8 1.6 9.5 1.9 45 17 37 255 14.6 0.1 15.2 14.6 09/11/2005 20:10:00 5.8 1.3 10.7 2.6 5.6 1.4 10.3 2.6 4.6 1.3 8.8 2.3 59 18 37 255 14.6 0 15.2 14.6 09/11/2005 20:20:00 5.5 1.5 10.7 2.6 5.4 1.6 10.3 2.3 4.5 1.5 7.6 1.9 68 20 62 255 14.4 0 14.9 14.4 09/11/2005 20:30:00 6.7 1.8 12.6 3 6.6 1.8 12.6 2.6 5.4 1.7 10.7 1.5 50 21 56 255 14.5 0 15.2 14.4 09/11/2005 20:40:00 7.4 1.5 13 3.4 7.3 1.5 12.6 2.6 5.8 1.5 10.3 2.3 38 17 34 255 14.6 0 15.2 14.6 09/11/2005 20:50:00 6.8 1.6 11.8 3.4 6.7 1.7 11.8 3 5.6 1.7 10.7 2.3 53 15 54 255 14.6 0 14.9 14.4 09/11/2005 21:00:00 6.5 1.3 9.9 3.8 6.3 1.3 9.9 3.4 5.3 1.2 9.1 2.3 54 16 52 255 14.4 0 14.6 14.4 09/11/2005 21:10:00 6.6 1.2 10.3 3.8 6.5 1.3 10.3 3.4 5.4 1.3 9.1 2.3 47 17 51 255 14.2 0 14.4 14.4 09/11/2005 21:20:00 7.3 1.5 11.1 3.8 7.2 1.5 11.1 3.8 6.1 1.5 11.1 2.3 46 15 35 255 14.2 0 14.4 14.4 09/11/2005 21:30:00 7.1 1.5 11.1 4.2 7 1.5 10.7 3.8 5.8 1.5 10.3 2.3 42 14 40 255 14.4 0 14.6 14.4 09/11/2005 21:40:00 6.7 1.5 10.3 2.3 6.6 1.6 10.3 1.9 5.4 1.5 9.1 1.9 39 15 31 255 14.4 0 14.6 14.4 09/11/2005 21:50:00 5.7 1.5 9.5 2.3 5.5 1.6 9.9 1.9 4.8 1.5 8 1.1 42 17 48 255 14.5 0 14.6 14.4 09/11/2005 22:00:00 5.2 1 8 3 5 1.1 8 2.6 4.1 1.1 7.6 1.1 38 15 49 255 14.4 0 14.6 14.4 09/11/2005 22:10:00 4 1 8.4 2.3 3.8 1.1 8 1.9 3.3 1.1 6.8 1.5 43 19 39 255 14.3 0 14.6 14.4 09/11/2005 22:20:00 5.6 1.6 9.1 2.3 5.4 1.7 9.1 1.5 4.6 1.7 8.8 1.1 30 18 25 255 14.4 0 14.6 14.4 09/11/2005 22:30:00 6.5 1.5 11.1 3 6.4 1.5 11.1 2.6 5.3 1.5 11.1 2.3 24 13 11 255 14.5 0 14.6 14.6 09/11/2005 22:40:00 6.9 1.5 10.7 3.8 6.8 1.5 11.1 3 5.4 1.7 10.3 1.9 19 16 23 255 14.5 0 14.6 14.4 09/11/2005 22:50:00 6.4 1.4 9.9 1.9 6.2 1.5 9.5 1.5 4.6 1.6 8.4 0.7 10 15 15 255 14.2 0 14.6 14.4 09/11/2005 23:00:00 7.1 1.6 11.1 3.8 7 1.6 11.1 3 5 1.9 10.7 1.1 7 16 4 255 14.2 0 14.4 14.1 09/11/2005 23:10:00 6.5 1.6 10.7 2.6 6.4 1.6 11.1 2.6 4.9 1.8 10.3 1.1 16 17 35 255 14.4 0 14.6 14.1 09/11/2005 23:20:00 6.9 1.7 10.7 2.6 6.7 1.7 10.3 3 5.4 1.6 9.5 1.9 31 18 24 255 14.7 0 15.2 14.6 09/11/2005 23:30:00 4.6 1 8 1.9 4.4 1.1 7.6 1.5 3.7 1.2 7.6 0.4 66 15 33 255 14.8 0 15.2 14.6 09/11/2005 23:40:00 4.9 1.2 8.8 2.3 4.8 1.2 8.8 1.9 4 1.2 8.4 1.1 72 17 76 255 14.6 0 14.9 14.6 09/11/2005 23:50:00 5.3 1.1 8.8 2.3 5.1 1.2 8.8 2.3 4.3 1.1 7.6 1.5 59 16 58 255 14.6 0 14.9 14.6 09/12/2005 00:00:00 5.3 1.6 10.3 2.3 5.1 1.7 10.3 1.5 4 1.4 8.8 1.5 37 26 352 255 14.3 0 14.6 14.1 09/12/2005 00:10:00 4.6 0.9 7.2 1.9 4.4 0.9 7.2 2.3 3.7 0.7 6.1 1.9 31 14 32 255 14.2 0 14.4 14.1 09/12/2005 00:20:00 4.2 0.9 6.8 2.3 4 1 7.2 1.5 3.4 0.9 6.5 1.5 50 20 23 255 14.3 0 14.6 14.1 09/12/2005 00:30:00 4.1 1 7.2 1.5 3.9 1 7.2 1.5 3.1 0.8 4.9 1.5 50 22 3 255 14.1 0 14.4 13.8 09/12/2005 00:40:00 4.5 1.3 9.9 1.5 4.3 1.4 9.1 0.7 3.3 1.2 8 0.7 22 20 27 255 14 0 14.4 13.8 09/12/2005 00:50:00 4.7 1.3 8.4 1.5 4.5 1.4 8.4 1.5 3.3 1.3 7.2 0.4 19 24 333 255 14.2 0.1 14.6 13.8 09/12/2005 01:00:00 3.4 0.8 5.3 1.5 3.2 0.9 5.3 0.7 2.7 0.8 5.3 1.1 43 18 37 255 14.5 0 14.6 14.4 09/12/2005 01:10:00 3.3 0.7 4.9 1.9 3.1 0.8 4.9 1.1 2.7 0.7 4.6 0.7 61 13 45 255 14.4 0 14.6 14.4 09/12/2005 01:20:00 3.6 0.8 5.7 1.5 3.3 0.9 5.3 0.7 2.8 0.9 5.3 0.7 51 17 51 255 14.2 0 14.4 14.1 09/12/2005 01:30:00 3 0.8 4.9 1.1 2.7 0.9 4.6 0.4 2.3 0.8 3.8 0.4 42 18 11 255 14 0 14.4 13.8 09/12/2005 01:40:00 3.3 1.2 6.5 0.4 3 1.4 5.7 0.4 2.5 1.2 5.3 0.7 57 21 86 255 13.9 0 14.1 13.8 09/12/2005 01:50:00 3.2 0.8 5.3 0.7 2.9 0.9 5.3 0.4 2.5 0.8 4.2 0.4 67 16 102 255 13.9 0 14.1 13.5 09/12/2005 02:00:00 2.8 1 5.7 0.7 2.4 1.1 5.7 0.4 2.2 0.8 4.6 0.7 55 14 73 255 13.6 0 13.8 13.5 09/12/2005 02:10:00 2.5 0.9 4.9 0.4 2.1 1 4.6 0.4 1.8 0.8 4.6 0.4 51 19 31 255 13.5 0 13.5 13.3 09/12/2005 02:20:00 2.6 0.7 4.6 1.1 2.3 0.8 4.2 0.4 1.7 0.7 3.8 0.4 77 13 56 255 13.2 0 13.5 13 09/12/2005 02:30:00 3.5 0.9 6.1 1.5 3.3 1 5.7 1.1 2.6 0.9 4.9 0.7 68 16 88 255 13.2 0 13.3 13 09/12/2005 02:40:00 4 0.8 6.1 2.3 3.8 0.8 5.7 1.9 3.3 0.8 5.3 1.9 53 16 50 255 13.5 0 13.5 13.3 09/12/2005 02:50:00 4.9 1.3 8.4 1.9 4.8 1.4 9.1 1.9 3.6 1.1 6.8 1.1 58 15 54 255 13.3 0 13.5 13 09/12/2005 03:00:00 5.5 1.4 8.8 2.6 5.3 1.4 8.4 2.6 4.3 1.2 7.6 1.9 53 15 56 255 13.2 0 13.3 13 09/12/2005 03:10:00 3.4 0.7 5.3 1.5 3.3 0.8 5.3 0.7 2.5 0.8 4.9 0.4 69 13 61 255 12.9 0.1 13.3 12.7 09/12/2005 03:20:00 3.2 0.6 4.6 1.5 3 0.7 4.9 1.1 2.4 0.8 4.2 0.4 52 14 53 255 12.8 0 12.7 12.7 09/12/2005 03:30:00 3.2 0.6 4.9 1.5 3 0.7 4.9 1.5 2.2 0.6 4.6 0.7 64 17 70 255 12.8 0 12.7 12.5 09/12/2005 03:40:00 3.5 0.5 4.9 2.3 3.3 0.6 4.6 1.9 2.6 0.6 4.2 1.1 77 9 70 255 12.3 0.1 12.7 11.9 09/12/2005 03:50:00 3.6 0.7 5.3 1.9 3.6 0.8 4.9 1.5 2.9 0.8 4.9 0.7 76 13 87 255 11.8 0 11.9 11.7 09/12/2005 04:00:00 3.9 1 6.5 1.5 3.7 1 6.5 1.5 2.6 1 4.9 0.4 83 17 89 255 11.7 0 11.7 11.7 09/12/2005 04:10:00 4.3 0.8 6.5 1.5 4.2 0.9 6.1 1.5 3.1 1 5.3 0.4 77 13 108 255 11.6 0 11.7 11.7 09/12/2005 04:20:00 4.5 0.7 6.5 3 4.5 0.7 6.5 2.3 3.4 0.8 5.3 1.1 88 14 82 255 11.7 0 11.7 11.7 09/12/2005 04:30:00 5 0.8 6.8 3 4.9 0.9 6.8 2.6 3.7 0.8 5.7 1.5 84 11 86 255 11.5 0 11.7 11.4 09/12/2005 04:40:00 4.7 0.8 7.2 2.6 4.6 0.9 7.2 1.9 3.6 0.9 6.5 1.1 78 13 66 255 11.4 0 11.7 11.4 09/12/2005 04:50:00 4.6 1 7.2 2.3 4.4 1 6.8 2.3 3.4 0.9 6.1 1.5 81 14 115 255 11.5 0 11.7 11.4 09/12/2005 05:00:00 4 0.9 6.1 2.3 3.8 0.9 6.1 1.9 3 1 5.7 0.4 89 13 97 255 11.5 0 11.7 11.4 09/12/2005 05:10:00 3.6 0.8 6.1 1.5 3.3 1 5.7 0.4 2.8 0.8 4.9 1.1 81 17 55 255 11.7 0 11.7 11.4 09/12/2005 05:20:00 3.8 1.2 6.8 1.5 3.6 1.2 6.1 1.1 3 1.2 6.1 0.4 90 19 112 255 11.7 0 11.9 11.7 09/12/2005 05:30:00 4.3 0.9 6.5 2.3 4.1 0.9 6.8 1.5 3.2 1 5.7 1.1 87 17 77 255 11.7 0 11.7 11.7 09/12/2005 05:40:00 4.4 1 7.2 1.9 4.3 0.9 6.5 2.3 3.5 1 6.5 1.1 75 17 61 255 11.6 0 11.7 11.4 09/12/2005 05:50:00 3.9 0.9 6.5 1.9 3.7 0.9 6.5 1.5 3.1 1 5.3 0.7 70 17 58 255 11.5 0 11.7 11.4 09/12/2005 06:00:00 4.1 0.8 6.1 2.3 4 0.8 6.1 1.9 3.4 0.9 5.7 1.1 76 12 78 255 11.5 0 11.7 11.4 09/12/2005 06:10:00 3.6 0.9 5.7 1.5 3.5 0.9 5.3 1.5 2.7 0.9 4.6 0.4 77 14 70 255 11.5 0 11.7 11.4 09/12/2005 06:20:00 3.4 0.6 4.9 1.9 3.2 0.6 4.9 1.5 2.5 0.7 4.9 1.1 91 13 95 255 11.3 0 11.4 11.1 09/12/2005 06:30:00 3.6 0.6 5.3 1.5 3.4 0.6 4.9 1.9 2.6 0.7 3.8 1.1 84 13 76 255 11.1 0 11.1 11.1 09/12/2005 06:40:00 3.4 0.6 4.9 1.9 3.3 0.6 4.9 1.5 2.5 0.8 4.2 0.4 82 12 90 255 11.1 0 11.1 10.9 09/12/2005 06:50:00 3.2 0.7 4.9 1.1 3 0.8 4.9 0.4 2.1 0.8 3.8 0.4 77 14 59 255 11 0 11.1 10.9 09/12/2005 07:00:00 3.1 0.5 4.2 1.9 2.9 0.6 4.6 1.5 2 0.7 3.4 0.4 76 10 72 255 11 0 11.1 10.9 09/12/2005 07:10:00 3.1 0.5 4.2 1.9 2.9 0.5 4.2 1.5 2.2 0.6 4.2 0.7 91 10 95 255 10.9 0 11.1 10.9 09/12/2005 07:20:00 3.1 0.6 4.6 1.5 2.8 0.6 4.2 0.7 2.2 0.8 3.8 0.4 94 12 88 255 11 0 11.1 10.9 09/12/2005 07:30:00 2.9 0.6 4.9 1.1 2.6 0.7 4.9 0.7 1.9 0.7 3.4 0.4 80 12 84 255 11.1 0 11.1 11.1 09/12/2005 07:40:00 2.6 0.7 4.2 1.1 2.4 0.8 4.2 0.7 1.8 0.8 3.8 0.4 74 14 70 255 11.2 0 11.4 11.1 09/12/2005 07:50:00 1.4 0.5 3 0.4 0.8 0.5 2.6 0.4 0.6 0.4 1.9 0.4 49 22 79 255 11.3 0 11.4 11.1 09/12/2005 08:00:00 1.7 0.7 3 0.4 1.2 0.8 3 0.4 0.9 0.7 2.6 0.4 88 22 104 255 11.3 0 11.4 11.1 09/12/2005 08:10:00 2.9 0.6 4.6 1.5 2.6 0.7 4.2 0.7 2 0.6 3.4 0.4 104 12 123 255 11.4 0 11.7 11.4 09/12/2005 08:20:00 2.8 0.6 4.6 1.1 2.5 0.7 4.2 1.1 1.9 0.7 3.4 0.4 113 15 94 255 11.5 0 11.7 11.4 09/12/2005 08:30:00 2.8 0.6 4.2 1.1 2.4 0.7 4.2 0.7 2 0.6 3.4 0.4 115 15 94 255 11.7 0 11.7 11.7 09/12/2005 08:40:00 3 0.6 4.2 1.1 2.7 0.7 3.8 0.4 1.9 0.8 3.8 0.4 107 13 101 255 11.7 0 11.7 11.7 09/12/2005 08:50:00 2.7 0.9 4.9 1.1 2.3 1 4.6 0.4 1.7 0.8 3.4 0.4 109 21 104 255 11.9 0 11.9 11.7 09/12/2005 09:00:00 2.7 0.9 4.9 0.7 2.3 1 4.6 0.4 1.8 0.9 4.2 0.4 111 19 100 255 12 0 12.2 11.9 09/12/2005 09:10:00 2.2 0.8 4.2 0.4 1.8 0.9 4.2 0.4 1.4 0.8 3.8 0.4 107 19 142 255 12.1 0 12.2 11.9 09/12/2005 09:20:00 2.1 0.6 4.2 0.7 1.6 0.7 3.4 0.4 1.3 0.8 3.8 0.4 113 19 117 255 12.3 0 12.2 12.2 09/12/2005 09:30:00 2.3 0.6 3.8 0.7 1.8 0.6 3.4 0.4 1.5 0.7 3 0.4 118 19 104 255 12.3 0 12.5 12.2 09/12/2005 09:40:00 1.9 0.6 3.4 0.4 1.4 0.7 3 0.4 1.2 0.7 3 0.4 129 17 110 255 12.4 0 12.5 12.2 09/12/2005 09:50:00 2.2 0.7 3.8 0.7 1.8 0.8 3.8 0.4 1.5 0.7 3 0.4 123 16 95 255 12.4 0 12.5 12.5 09/12/2005 10:00:00 3 0.5 4.2 1.1 2.7 0.5 3.8 0.7 2.1 0.6 3.4 0.4 111 11 107 255 12.6 0 12.7 12.5 09/12/2005 10:10:00 3.1 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2.1 0.7 3.8 0.4 112 15 119 255 12.7 0 12.7 12.7 09/12/2005 10:20:00 2.5 0.5 3.8 1.1 2.2 0.6 3.8 0.4 1.7 0.6 3.4 0.4 111 13 125 255 12.8 0 12.7 12.7 09/12/2005 10:30:00 1.3 0.7 3 0.4 0.9 0.7 2.6 0.4 0.7 0.6 3 0.4 92 21 116 255 12.9 0.1 13 12.7 09/12/2005 10:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 43 24 255 13.2 0 13.3 13 09/12/2005 10:50:00 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 90 51 132 255 13.3 0 13.3 13 09/12/2005 11:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 110 32 111 255 13.3 0 13.3 13.3 09/12/2005 11:10:00 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 308 13 294 255 13.3 0 13.5 13.3 09/12/2005 11:20:00 1.4 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 281 12 291 255 13.4 0 13.5 13.3 09/12/2005 11:30:00 1.3 0.5 2.6 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 252 15 277 255 13.5 0 13.5 13.3 09/12/2005 11:40:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 249 19 237 255 13.4 0 13.5 13.3 09/12/2005 11:50:00 1.6 1 3.8 0.4 1.2 1 3.4 0.4 1 0.8 3.4 0.4 260 19 255 255 13.3 0 13.5 13.3 09/12/2005 12:00:00 2.2 0.6 3.8 0.7 1.8 0.7 3.4 0.4 1.2 0.7 3 0.4 263 17 234 255 13.5 0 13.8 13.3 09/12/2005 12:10:00 2.1 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 262 17 242 255 13.7 0 13.8 13.5 09/12/2005 12:20:00 2.9 0.8 4.9 1.1 2.6 1 4.6 0.4 1.9 1 4.6 0.4 257 21 247 255 13.6 0 13.8 13.5 09/12/2005 12:30:00 2.5 0.8 4.9 0.4 2.1 0.9 4.6 0.4 1.5 0.8 4.2 0.4 240 21 240 255 13.5 0 13.5 13.3 09/12/2005 12:40:00 3.8 1.7 8.4 0.7 3.7 1.8 8.4 0.4 2.6 1.5 8 0.4 225 20 229 255 13.1 0.2 13.5 12.7 09/12/2005 12:50:00 3.7 1.3 7.2 1.1 3.6 1.4 7.2 0.7 2.5 1.2 6.1 0.4 231 26 249 255 12.3 0.2 12.7 11.9 09/12/2005 13:00:00 3.8 1.2 6.8 1.1 3.6 1.3 6.8 0.4 2.8 1.3 6.5 0.4 243 20 262 255 11.7 0 12.2 11.7 09/12/2005 13:10:00 3.9 1.1 6.8 0.7 3.8 1.2 6.5 0.7 2.7 1.3 6.5 0.4 251 22 257 255 11.3 0 11.7 11.1 09/12/2005 13:20:00 3.7 1.3 6.8 1.1 3.6 1.4 6.8 0.4 2.5 1.2 7.2 0.4 244 18 247 255 11.1 0 11.4 11.1 09/12/2005 13:30:00 3.6 1.5 7.2 0.4 3.5 1.7 7.2 0.4 2.4 1.3 5.7 0.4 244 30 243 255 11.3 0 11.4 11.1 09/12/2005 13:40:00 3.4 1.1 6.8 1.1 3.2 1.2 6.8 0.7 2.3 1.2 6.1 0.4 246 24 242 255 11.3 0 11.4 11.1 09/12/2005 13:50:00 2.9 0.9 6.1 0.4 2.7 1 5.7 0.4 2 1 4.6 0.4 238 20 247 255 11.4 0 11.7 11.4 09/12/2005 14:00:00 3.2 1.1 6.1 1.1 3 1.1 5.7 0.7 2 1.2 5.7 0.4 230 19 223 255 11.3 0 11.7 11.1 09/12/2005 14:10:00 3.8 0.9 5.7 1.5 3.6 1 5.7 1.1 2.7 0.9 4.9 0.4 215 15 227 255 11.2 0 11.4 11.1 09/12/2005 14:20:00 2.3 1 4.9 0.4 1.9 1 4.6 0.4 1.2 0.9 3.4 0.4 218 16 211 255 11.1 0 11.1 11.1 09/12/2005 14:30:00 1.3 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.6 2.3 0.4 188 20 204 255 11.2 0 11.4 11.1 09/12/2005 14:40:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.6 0.7 3 0.4 166 12 158 255 11.4 0 11.4 11.4 09/12/2005 14:50:00 2.1 0.5 3.4 1.1 1.8 0.5 3 0.7 1.4 0.6 2.6 0.4 161 15 156 255 11.5 0 11.7 11.4 09/12/2005 15:00:00 2.5 0.7 4.6 0.7 2.2 0.8 4.2 0.4 1.6 0.8 3.8 0.4 155 15 136 255 11.5 0 11.7 11.4 09/12/2005 15:10:00 3.5 0.7 4.9 1.5 3.2 0.8 4.9 1.1 2.5 0.8 4.2 0.4 146 13 144 255 11.5 0 11.7 11.4 09/12/2005 15:20:00 2.7 0.8 4.6 0.7 2.4 0.9 4.2 0.4 1.8 0.9 4.2 0.4 138 17 150 255 11.6 0 11.7 11.4 09/12/2005 15:30:00 2.9 0.8 5.3 1.1 2.6 0.9 5.3 0.4 2 0.8 4.2 0.4 126 16 126 255 11.7 0 11.9 11.7 09/12/2005 15:40:00 2.4 0.8 4.9 0.4 2 0.9 4.6 0.4 1.5 0.8 3.8 0.4 125 21 134 255 11.9 0 11.9 11.7 09/12/2005 15:50:00 2.4 0.7 4.6 0.7 2 0.8 4.2 0.4 1.5 0.8 4.2 0.4 116 20 104 255 11.9 0 11.9 11.9 09/12/2005 16:00:00 3 0.7 4.9 1.1 2.6 0.8 4.6 1.1 2.1 0.8 4.2 0.4 113 18 158 255 12 0 12.2 11.9 09/12/2005 16:10:00 2.3 0.6 3.8 0.7 1.9 0.7 3.8 0.4 1.4 0.6 3 0.4 109 20 129 255 12.2 0 12.5 11.9 09/12/2005 16:20:00 2.5 0.5 3.8 1.5 2.2 0.6 3.8 0.4 1.7 0.7 3.4 0.4 104 12 96 255 12.3 0 12.5 12.2 09/12/2005 16:30:00 1.3 0.8 3.8 0.4 1 0.8 3 0.4 0.8 0.7 3 0.4 116 22 106 255 12.4 0 12.5 12.2 09/12/2005 16:40:00 0.8 0.5 2.6 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 139 27 87 255 12.4 0 12.5 12.5 09/12/2005 16:50:00 1.2 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 127 24 99 255 12.4 0 12.5 12.2 09/12/2005 17:00:00 3.1 0.5 4.2 1.9 2.8 0.6 4.2 1.1 2.5 0.6 3.8 1.1 131 9 129 255 12.3 0 12.5 12.2 09/12/2005 17:10:00 1.8 0.7 3.4 0.4 1.3 0.8 3 0.4 1 0.6 2.3 0.4 124 18 129 255 12 0 12.2 11.9 09/12/2005 17:20:00 1.4 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 114 15 94 255 11.9 0 11.9 11.9 09/12/2005 17:30:00 2.2 0.5 3 1.1 1.7 0.6 3 0.4 1.5 0.5 2.6 0.4 146 6 151 255 11.8 0 11.9 11.7 09/12/2005 17:40:00 2.3 0.6 3.8 0.4 2 0.7 3.4 0.4 1.5 0.7 3.4 0.4 131 11 133 255 11.8 0 11.9 11.7 09/12/2005 17:50:00 1.2 0.7 3 0.4 0.8 0.7 2.6 0.4 0.7 0.5 2.3 0.4 48 76 295 255 11.7 0 11.9 11.7 09/12/2005 18:00:00 1.4 0.8 3 0.4 1 0.8 3 0.4 0.7 0.6 2.3 0.4 263 66 295 255 11.5 0 11.7 11.4 09/12/2005 18:10:00 1.4 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 314 86 55 255 11.4 0 11.7 11.4 09/12/2005 18:20:00 1.1 0.8 3 0.4 0.8 0.7 2.6 0.4 0.7 0.6 2.3 0.4 124 47 76 255 11.3 0 11.4 11.1 09/12/2005 18:30:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 46 66 10 255 11.2 0 11.4 11.1 09/12/2005 18:40:00 1.7 0.5 2.6 0.4 1.2 0.6 2.3 0.4 0.8 0.5 2.3 0.4 47 14 43 255 11.1 0 11.4 11.1 09/12/2005 18:50:00 2.2 0.3 3 1.5 1.8 0.4 2.6 1.1 1.1 0.5 2.3 0.4 32 10 12 255 11.1 0 11.1 11.1 09/12/2005 19:00:00 1.7 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.5 1.9 0.4 55 13 53 255 11 0 11.1 10.9 09/12/2005 19:10:00 1.6 0.4 2.6 0.7 1.1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 74 9 73 255 10.7 0 10.9 10.6 09/12/2005 19:20:00 1.7 0.4 2.6 0.7 1.2 0.4 2.3 0.4 0.6 0.4 2.3 0.4 71 14 69 255 10.5 0 10.6 10.3 09/12/2005 19:30:00 1.4 0.4 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.2 1.5 0.4 85 12 73 255 10.3 0 10.6 10.3 09/12/2005 19:40:00 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 66 15 84 255 10.2 0 10.3 10.3 09/12/2005 19:50:00 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.7 0.4 1.5 0.4 73 7 72 255 10.1 0 10.3 9.8 09/12/2005 20:00:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 122 39 89 255 9.7 0.1 9.8 9.6 09/12/2005 20:10:00 0.8 0.6 2.6 0.4 0.6 0.5 2.6 0.4 0.5 0.4 2.3 0.4 125 64 171 255 9.4 0 9.6 9.3 09/12/2005 20:20:00 1.5 0.7 3.8 0.4 0.9 0.8 3.4 0.4 0.7 0.6 3.8 0.4 249 24 255 255 9.1 0 9.3 9 09/12/2005 20:30:00 1.2 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.4 0.1 1.1 0.4 237 15 260 255 8.9 0 9 8.8 09/12/2005 20:40:00 1.8 0.5 3.4 0.4 1.4 0.7 3.4 0.4 0.6 0.4 2.3 0.4 244 13 246 255 8.6 0 8.8 8.5 09/12/2005 20:50:00 1.9 0.4 3 1.1 1.5 0.5 3.4 0.4 0.6 0.4 2.3 0.4 234 10 231 255 8.5 0 8.8 8.5 09/12/2005 21:00:00 1.7 0.5 3 0.4 1.3 0.6 3 0.4 0.6 0.4 2.3 0.4 229 21 238 255 8.7 0 8.8 8.5 09/12/2005 21:10:00 1.9 0.6 3.4 0.4 1.5 0.7 3.8 0.4 0.6 0.4 2.3 0.4 216 13 220 255 8.8 0 9 8.8 09/12/2005 21:20:00 1.2 0.6 3 0.4 0.9 0.6 2.6 0.4 0.4 0.2 1.5 0.4 207 17 234 255 8.7 0 9 8.8 09/12/2005 21:30:00 0.8 0.5 2.6 0.4 0.5 0.4 2.6 0.4 0.4 0.2 1.1 0.4 237 7 228 255 8.6 0 8.8 8.5 09/12/2005 21:40:00 1.4 0.7 3 0.4 1 0.7 2.3 0.4 0.5 0.3 1.5 0.4 238 16 215 255 8.5 0 8.8 8.5 09/12/2005 21:50:00 2.1 0.3 3 1.1 1.7 0.4 2.6 0.7 0.8 0.4 1.9 0.4 207 8 213 255 8.5 0 8.8 8.5 09/12/2005 22:00:00 1.5 0.3 2.3 0.7 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 201 5 217 255 8.5 0 8.8 8.5 09/12/2005 22:10:00 1.7 0.2 2.3 1.1 1.3 0.2 1.9 0.7 0.5 0.2 1.1 0.4 199 3 204 255 8.5 0 8.8 8.5 09/12/2005 22:20:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 179 8 202 255 8.5 0 8.8 8.5 09/12/2005 22:30:00 0.9 0.4 3 0.4 0.6 0.4 2.6 0.4 0.4 0 0.4 0.4 183 11 202 255 8.5 0 8.8 8.5 09/12/2005 22:40:00 1.7 0.5 2.6 0.4 1.3 0.6 2.3 0.4 0.5 0.3 1.5 0.4 199 11 206 255 8.5 0 8.8 8.5 09/12/2005 22:50:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 1 0.5 2.3 0.4 189 8 196 255 8.7 0 8.8 8.5 09/12/2005 23:00:00 2.6 0.5 4.2 1.1 2.4 0.5 3.4 1.1 1.3 0.6 2.6 0.4 190 9 188 255 8.8 0 9 8.8 09/12/2005 23:10:00 2.2 0.5 3.4 1.1 2.3 0.4 3 1.5 1.2 0.5 2.3 0.4 182 10 189 255 8.9 0 9 9 09/12/2005 23:20:00 1.6 0.5 2.6 0.4 1.7 0.5 3 0.4 0.8 0.5 2.3 0.4 170 8 157 255 9 0 9 9 09/12/2005 23:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 52 69 175 255 9 0 9 9 09/12/2005 23:40:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 136 64 187 255 8.9 0 9 9 09/12/2005 23:50:00 1.8 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.1 0.6 3 0.4 173 9 171 255 8.9 0 9 9 09/13/2005 00:00:00 2.5 0.5 3.8 1.5 2.8 0.5 4.2 1.1 1.9 0.5 3 0.7 170 9 167 255 9 0 9.6 9 09/13/2005 00:10:00 2.7 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2 0.6 3.4 0.4 169 9 181 255 9.2 0 9.3 9 09/13/2005 00:20:00 2.7 0.5 4.2 1.1 2.8 0.5 4.2 1.1 2 0.6 3.4 0.7 168 9 158 255 9.4 0 9.6 9.3 09/13/2005 00:30:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.1 1.6 0.7 3.4 0.4 167 9 158 255 9.5 0 9.6 9.6 09/13/2005 00:40:00 2.4 0.4 3.4 1.5 2.5 0.5 3.8 1.5 1.7 0.5 3 0.4 170 9 168 255 9.7 0 9.8 9.6 09/13/2005 00:50:00 2.3 0.5 3.4 1.1 2.4 0.5 3.8 1.1 1.5 0.6 3.4 0.4 175 11 154 255 9.8 0 9.8 9.6 09/13/2005 01:00:00 2.1 0.4 3.4 1.1 2 0.5 3.4 0.7 1.2 0.5 2.6 0.4 173 12 167 255 9.8 0 10.1 9.6 09/13/2005 01:10:00 2.2 0.4 3.4 1.1 2.3 0.5 3.8 1.1 1.4 0.5 3 0.4 172 9 182 255 9.7 0 9.8 9.6 09/13/2005 01:20:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 0.7 1.6 0.6 3.4 0.4 170 12 158 255 9.8 0 9.8 9.6 09/13/2005 01:30:00 2.3 0.6 4.6 1.1 2.4 0.8 4.9 0.4 1.4 0.7 3 0.4 174 13 143 255 9.9 0 10.1 9.6 09/13/2005 01:40:00 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.5 0.4 2.3 0.4 180 19 178 255 9.9 0.1 10.1 9.6 09/13/2005 01:50:00 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 312 53 345 255 9.5 0 9.8 9.3 09/13/2005 02:00:00 0.8 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 0 337 255 9.4 0 9.6 9.3 09/13/2005 02:10:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 337 0 337 255 9.2 0 9.3 9 09/13/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 0 255 255 9 0 9 9 09/13/2005 02:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 0 337 255 8.9 0 9 8.8 09/13/2005 02:40:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.4 0.1 1.1 0.4 230 72 189 255 8.7 0 9 8.8 09/13/2005 02:50:00 1.4 0.5 2.3 0.4 1.2 0.6 2.3 0.4 0.4 0.2 1.1 0.4 171 9 192 255 8.7 0 8.8 8.5 09/13/2005 03:00:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 76 69 174 255 8.7 0 8.8 8.5 09/13/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 255 255 8.5 0 8.8 8.5 09/13/2005 03:20:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 23 5 15 255 8.5 0 8.8 8.5 09/13/2005 03:30:00 1.2 0.5 2.3 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 10 8 14 255 8.5 0 8.8 8.5 09/13/2005 03:40:00 1.1 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 9 2 15 255 8.5 0 8.8 8.5 09/13/2005 03:50:00 1.2 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 19 13 8 255 8.5 0 8.8 8.5 09/13/2005 04:00:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 37 255 8.5 0 8.8 8.5 09/13/2005 04:10:00 1.1 0.3 2.3 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 45 9 37 255 8.4 0 8.5 8.5 09/13/2005 04:20:00 1.3 0.4 2.3 0.4 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 64 15 51 255 8.4 0 8.5 8.5 09/13/2005 04:30:00 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 65 5 63 255 8.4 0 8.5 8.5 09/13/2005 04:40:00 1.3 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 75 8 80 255 8.4 0 8.8 8.5 09/13/2005 04:50:00 0.8 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 64 0 64 255 8.4 0 8.5 8.5 09/13/2005 05:00:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 52 15 34 255 8.4 0 8.5 8.5 09/13/2005 05:10:00 1.1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 7 6 19 255 8.4 0 8.8 8.3 09/13/2005 05:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 3 255 8.2 0 8.5 8 09/13/2005 05:30:00 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 11 10 24 255 8.1 0 8.5 8 09/13/2005 05:40:00 1.4 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 27 11 40 255 8.1 0 8.3 8 09/13/2005 05:50:00 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 37 12 32 255 8.1 0 8.3 8 09/13/2005 06:00:00 1.5 0.5 3 0.4 1 0.6 2.6 0.4 0.6 0.4 2.3 0.4 41 9 30 255 8 0 8.3 7.8 09/13/2005 06:10:00 2 0.4 3 0.7 1.6 0.6 2.6 0.4 1.2 0.6 2.3 0.4 42 10 45 255 7.8 0 8 7.8 09/13/2005 06:20:00 1.1 0.7 2.6 0.4 0.7 0.6 2.6 0.4 0.5 0.4 2.3 0.4 60 15 51 255 7.8 0 7.8 7.5 09/13/2005 06:30:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 45 17 46 255 7.6 0 7.8 7.5 09/13/2005 06:40:00 1.5 0.4 2.3 0.4 1 0.4 1.9 0.4 0.7 0.4 2.3 0.4 47 7 49 255 7.6 0 7.8 7.5 09/13/2005 06:50:00 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 50 12 38 255 7.7 0 7.8 7.5 09/13/2005 07:00:00 1 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 54 11 53 255 7.7 0 7.8 7.5 09/13/2005 07:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 13 55 255 8.1 0.2 8.8 7.8 09/13/2005 07:20:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 52 1 52 255 8.7 0.1 9 8.5 09/13/2005 07:30:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 53 0 53 255 8.4 0 8.5 8.3 09/13/2005 07:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 8.2 0 8.5 8.3 09/13/2005 07:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 8.2 0 8.5 8.3 09/13/2005 08:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 8.5 0 8.8 8.3 09/13/2005 08:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 8.9 0.1 9.3 8.8 09/13/2005 08:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 9.6 0.2 10.3 9 09/13/2005 08:30:00 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 70 17 81 255 11.1 0.4 11.9 10.3 09/13/2005 08:40:00 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 118 28 142 255 12.2 0.1 12.5 11.9 09/13/2005 08:50:00 1.1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 157 24 134 255 12.4 0 12.5 12.2 09/13/2005 09:00:00 1.5 0.5 3 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 157 22 138 255 13.2 0.3 13.5 12.5 09/13/2005 09:10:00 1.7 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1.2 0.8 3.4 0.4 172 27 163 255 13.9 0.1 14.4 13.5 09/13/2005 09:20:00 1.9 0.8 3.8 0.4 1.7 0.7 3.8 0.4 1.4 0.8 3 0.4 180 22 211 255 14.4 0.1 14.6 14.1 09/13/2005 09:30:00 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 195 38 209 255 14.7 0 15.2 14.6 09/13/2005 09:40:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.7 0.5 2.3 0.4 214 24 219 255 15 0.1 15.7 14.9 09/13/2005 09:50:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 215 23 192 255 15.1 0 15.7 14.9 09/13/2005 10:00:00 1.8 0.5 3.4 0.4 1.8 0.5 3.4 0.4 1.4 0.6 3 0.4 207 24 242 255 15.1 0.1 15.7 15.2 09/13/2005 10:10:00 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.6 0.4 230 28 257 255 15.2 0.1 15.7 15.2 09/13/2005 10:20:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.5 2.3 0.4 315 69 187 255 15.1 0.1 15.7 15.2 09/13/2005 10:30:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.5 0.7 3 0.4 291 56 232 255 15 0.2 15.7 14.6 09/13/2005 10:40:00 1.9 0.9 3.8 0.4 1.8 1 3.8 0.4 1.6 0.9 3.4 0.4 255 45 228 255 14.4 0.1 15.2 14.1 09/13/2005 10:50:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 271 30 255 255 13.6 0.2 14.6 13.3 09/13/2005 11:00:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1 0.6 2.3 0.4 185 27 171 255 13.8 0.3 14.6 13.3 09/13/2005 11:10:00 1.5 0.5 3 0.4 1.4 0.6 3.4 0.4 1.2 0.6 2.6 0.4 178 28 189 255 14.2 0.1 14.6 13.8 09/13/2005 11:20:00 1.5 0.7 3.4 0.4 1.6 0.7 3.8 0.4 1.4 0.7 2.6 0.4 193 28 203 255 14.3 0 14.9 14.4 09/13/2005 11:30:00 0.8 0.5 2.3 0.4 1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 234 43 233 255 14.8 0.1 15.7 14.6 09/13/2005 11:40:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.9 0.4 291 43 286 255 15.2 0.4 16.3 14.9 09/13/2005 11:50:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.1 0.4 157 58 189 255 15.9 0.2 16.6 15.7 09/13/2005 12:00:00 1.1 0.7 3 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.6 0.4 255 66 204 255 15.5 0.2 16.3 14.9 09/13/2005 12:10:00 1.1 0.7 3 0.4 1.2 0.7 3 0.4 0.9 0.6 2.6 0.4 260 45 219 255 15 0 15.7 14.9 09/13/2005 12:20:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 220 41 310 255 15 0 15.5 14.9 09/13/2005 12:30:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.5 1.9 0.4 279 53 223 255 15.9 0.3 16.3 15.2 09/13/2005 12:40:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 1 0.6 2.6 0.4 299 29 299 255 15.9 0 16.6 15.7 09/13/2005 12:50:00 1.8 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.3 0.8 3.4 0.4 330 23 343 255 15.6 0 16.3 15.5 09/13/2005 13:00:00 2.2 0.4 3.4 1.1 2 0.4 3 0.7 1.6 0.5 3.4 0.4 347 26 347 255 15.6 0 16.3 15.5 09/13/2005 13:10:00 2.1 0.8 3.8 0.4 2 0.8 4.2 0.4 1.6 0.8 3.4 0.4 345 23 324 255 16.3 0.2 16.8 15.7 09/13/2005 13:20:00 2.2 0.7 3.8 0.4 2 0.7 3.4 0.4 1.5 0.7 3.4 0.4 323 38 266 255 16.7 0 17.1 16.6 09/13/2005 13:30:00 2.7 0.9 4.6 0.4 2.4 1 4.6 0.4 1.8 1 4.6 0.4 317 35 298 255 17.3 0 17.7 17.1 09/13/2005 13:40:00 2.8 0.9 5.7 0.4 2.7 0.9 5.3 0.7 2.2 1 5.3 0.4 318 27 318 255 17.7 0 18.2 17.4 09/13/2005 13:50:00 2.3 0.7 3.8 0.4 2.1 0.8 3.8 0.4 1.6 0.7 3.4 0.4 312 28 358 255 18 0.1 18.5 17.7 09/13/2005 14:00:00 2.7 0.6 4.2 1.1 2.5 0.6 3.8 1.1 2 0.7 3.8 0.7 351 17 336 255 17.6 0.2 18 17.1 09/13/2005 14:10:00 1.8 1 4.2 0.4 1.6 0.9 3.8 0.4 1.2 0.8 3 0.4 335 33 334 255 17.3 0 17.4 17.1 09/13/2005 14:20:00 2.6 0.6 3.8 1.1 2.2 0.7 3.8 0.7 1.8 0.7 3 0.4 336 15 355 255 17 0.4 17.7 16.3 09/13/2005 14:30:00 2.4 0.6 3.8 1.1 2.1 0.6 3.4 0.7 1.4 0.7 3 0.4 340 22 351 255 16.8 0.5 18 16.3 09/13/2005 14:40:00 2.4 0.8 4.6 0.4 2.1 0.8 4.2 0.4 1.6 0.8 3.4 0.4 357 19 336 255 17.9 0 18.2 17.4 09/13/2005 14:50:00 2.7 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2 0.7 3.8 0.4 16 24 7 255 17.3 0.3 18.2 16.8 09/13/2005 15:00:00 1.5 0.7 3 0.4 1.3 0.6 3 0.4 1 0.6 3 0.4 14 24 20 255 16.6 0.1 17.4 16.3 09/13/2005 15:10:00 1.9 0.6 3 0.4 1.5 0.6 3 0.4 1.1 0.7 3 0.4 331 32 336 255 16.1 0 16.8 16 09/13/2005 15:20:00 1.9 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.3 0.8 3 0.4 293 26 314 255 15.9 0 16.6 15.7 09/13/2005 15:30:00 1.9 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3 0.4 290 43 337 255 15.7 0 15.7 15.7 09/13/2005 15:40:00 2.3 0.9 4.2 0.4 2.1 0.9 4.2 0.4 1.5 0.8 3.4 0.4 3 28 16 255 15.9 0 16.3 15.7 09/13/2005 15:50:00 1.6 0.7 3.4 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 294 29 244 255 15.9 0.1 16.3 15.7 09/13/2005 16:00:00 2.4 0.8 4.6 0.4 2.2 0.8 4.6 0.4 1.7 0.8 4.2 0.4 294 29 300 255 16.2 0.1 16.8 16 09/13/2005 16:10:00 2.5 0.6 4.2 1.1 2.2 0.6 4.2 0.4 1.6 0.8 3.4 0.4 314 22 294 255 15.9 0.2 16.8 15.5 09/13/2005 16:20:00 1.5 0.8 3 0.4 1.2 0.8 3 0.4 0.8 0.6 2.6 0.4 315 26 295 255 15.3 0.2 16 15.2 09/13/2005 16:30:00 2.1 0.5 3.8 0.4 1.9 0.6 3.4 0.4 1.5 0.6 3 0.4 295 13 301 255 15 0.1 15.7 14.9 09/13/2005 16:40:00 1.9 1 3.8 0.4 1.7 1 3.4 0.4 1.3 0.8 3 0.4 279 22 244 255 14.8 0 15.5 14.6 09/13/2005 16:50:00 2.2 0.8 4.2 0.4 1.9 0.9 4.2 0.4 1.5 0.8 3.4 0.4 291 21 255 255 14.7 0 15.2 14.6 09/13/2005 17:00:00 2.1 0.8 3.4 0.4 1.9 0.9 3.4 0.4 1.5 0.8 3 0.4 262 15 249 255 14.6 0 15.2 14.4 09/13/2005 17:10:00 1.9 0.8 3.4 0.4 1.7 0.8 3 0.4 1.2 0.7 2.6 0.4 264 22 264 255 14.3 0.2 14.9 14.1 09/13/2005 17:20:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.5 0.6 2.6 0.4 263 17 287 255 14.1 0.1 14.6 13.8 09/13/2005 17:30:00 2 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.2 0.6 3 0.4 260 14 267 255 13.8 0 14.4 13.5 09/13/2005 17:40:00 2 0.5 3 0.4 1.8 0.5 3 0.4 1.1 0.6 2.6 0.4 263 11 263 255 13.5 0 14.1 13.3 09/13/2005 17:50:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 276 7 263 255 12.9 0 13.5 12.5 09/13/2005 18:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 284 0 284 255 12.3 0.1 12.7 11.9 09/13/2005 18:10:00 0.9 0.4 1.5 0.4 0.8 0.3 1.1 0.4 0.5 0.2 1.1 0.4 283 0 284 255 11.8 0.1 12.5 11.7 09/13/2005 18:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 283 0 283 255 11.6 0 11.9 11.4 09/13/2005 18:30:00 0.6 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 281 3 283 255 11.4 0 11.7 11.4 09/13/2005 18:40:00 0.9 0.3 1.5 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 272 0 272 255 11.1 0 11.4 10.9 09/13/2005 18:50:00 1.6 0.2 2.3 1.1 1.3 0.3 1.9 0.7 0.4 0.1 0.7 0.4 273 1 274 255 10.7 0.1 11.1 10.6 09/13/2005 19:00:00 1.1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 333 41 10 255 10.4 0.1 10.6 10.3 09/13/2005 19:10:00 1 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 354 8 11 255 10 0 10.3 9.8 09/13/2005 19:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 355 0 355 255 9.7 0 9.8 9.6 09/13/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 355 0 255 255 9.5 0 9.6 9.3 09/13/2005 19:40:00 0.9 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 355 0 355 255 9.2 0.1 9.3 9 09/13/2005 19:50:00 1.3 0.4 1.9 0.7 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 28 26 57 255 9 0 9 8.8 09/13/2005 20:00:00 1.7 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1 0.3 1.5 0.4 62 2 58 255 8.6 0.1 8.8 8.5 09/13/2005 20:10:00 2.1 0.3 3 1.1 1.8 0.4 2.6 1.1 1.2 0.3 1.9 0.4 64 5 81 255 8.5 0 8.8 8.5 09/13/2005 20:20:00 2.2 0.3 3 1.5 2 0.3 3 1.1 1.1 0.4 2.3 0.4 63 8 49 255 8.3 0 8.5 8.3 09/13/2005 20:30:00 2.2 0.4 3.4 1.1 1.9 0.4 3.8 0.7 0.8 0.5 2.3 0.4 58 12 72 255 8.1 0 8.5 8 09/13/2005 20:40:00 2.2 0.4 3.4 1.5 1.9 0.4 3 0.7 0.6 0.4 1.9 0.4 58 8 71 255 8 0 8.3 7.8 09/13/2005 20:50:00 2 0.4 2.6 1.1 1.6 0.4 2.6 0.4 0.7 0.3 1.5 0.4 64 7 62 255 8 0 8.3 8 09/13/2005 21:00:00 2.3 0.3 3.4 1.5 2.1 0.3 3 1.1 1.1 0.4 1.9 0.4 65 8 65 255 7.9 0 8.3 7.8 09/13/2005 21:10:00 2.5 0.3 3.4 1.9 2.3 0.3 3 1.1 1.2 0.4 2.3 0.4 75 9 53 255 7.8 0 7.8 7.8 09/13/2005 21:20:00 2.9 0.5 3.8 1.5 2.7 0.5 3.8 1.1 1.4 0.5 2.3 0.4 79 9 86 255 7.8 0 8 7.8 09/13/2005 21:30:00 2.4 0.4 3.4 1.1 2.1 0.5 3.4 0.7 1.1 0.5 2.3 0.4 72 8 86 255 7.9 0 8 7.8 09/13/2005 21:40:00 2.5 0.4 3.4 1.5 2.2 0.4 3 1.1 0.8 0.4 1.9 0.4 88 9 79 255 7.7 0 7.8 7.5 09/13/2005 21:50:00 2.5 0.3 3.4 1.5 2.2 0.4 3.4 1.1 1 0.4 1.9 0.4 96 9 68 255 7.6 0 7.8 7.5 09/13/2005 22:00:00 2.3 0.4 3 1.1 2 0.4 2.6 0.7 0.8 0.4 1.9 0.4 104 10 113 255 7.4 0 7.5 7.3 09/13/2005 22:10:00 2.3 0.3 3 1.5 2 0.4 3 1.1 0.9 0.5 1.9 0.4 98 11 87 255 7.3 0 7.5 7.3 09/13/2005 22:20:00 2.2 0.3 3 1.5 1.9 0.3 2.6 1.1 0.7 0.4 1.9 0.4 100 9 87 255 7.3 0 7.5 7.3 09/13/2005 22:30:00 2.6 0.3 3.4 1.5 2.3 0.4 3.4 1.1 1.1 0.5 2.6 0.4 101 10 95 255 7.3 0 7.5 7.3 09/13/2005 22:40:00 2.7 0.2 3.4 1.9 2.4 0.3 3 1.5 1.5 0.4 2.3 0.4 94 5 99 255 7.3 0 7.5 7.3 09/13/2005 22:50:00 2.2 0.4 3 1.5 1.8 0.4 3 0.7 0.6 0.4 1.9 0.4 95 9 96 255 7.3 0 7.5 7.3 09/13/2005 23:00:00 2.1 0.3 3 1.1 1.8 0.4 2.6 0.7 0.6 0.4 1.9 0.4 76 7 68 255 7.5 0 7.8 7.3 09/13/2005 23:10:00 1.9 0.3 2.6 1.5 1.5 0.4 2.6 0.7 0.4 0.1 1.1 0.4 78 9 84 255 7.8 0 8 7.5 09/13/2005 23:20:00 2 0.3 2.6 1.5 1.6 0.3 2.6 1.1 0.5 0.3 1.5 0.4 90 9 93 255 8 0 8 7.8 09/13/2005 23:30:00 2.4 0.3 3.4 1.9 2.2 0.3 3 1.5 1 0.4 1.9 0.4 93 7 98 255 8 0 8.3 8 09/13/2005 23:40:00 2.8 0.3 3.8 1.9 2.5 0.4 3.8 1.1 1.5 0.5 3 0.4 97 8 100 255 8.3 0.1 8.5 8 09/13/2005 23:50:00 2.6 0.5 4.2 1.5 2.3 0.5 3.8 1.1 1.1 0.5 2.6 0.4 100 10 88 255 8.7 0 9 8.5 09/14/2005 00:00:00 2.6 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.2 0.7 3 0.4 109 12 103 255 8.9 0 9 8.8 09/14/2005 00:10:00 2.1 0.6 3.4 0.4 1.7 0.6 3 0.4 0.6 0.5 2.3 0.4 115 17 117 255 8.9 0 9 9 09/14/2005 00:20:00 2.2 0.5 3.4 0.7 1.9 0.5 3 0.7 0.9 0.6 2.3 0.4 104 12 83 255 8.9 0 9 9 09/14/2005 00:30:00 2.4 0.4 3.4 1.5 2.1 0.4 3 0.7 1.1 0.5 2.3 0.4 103 13 79 255 8.9 0 9 8.8 09/14/2005 00:40:00 1.8 0.6 3.4 0.7 1.3 0.7 3 0.4 0.6 0.4 2.3 0.4 121 15 111 255 8.9 0 9 8.8 09/14/2005 00:50:00 1.8 0.5 3 0.4 1.2 0.7 2.6 0.4 0.5 0.3 2.3 0.4 109 17 93 255 9 0 9 9 09/14/2005 01:00:00 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 99 58 140 255 8.9 0 9 8.8 09/14/2005 01:10:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 124 0 124 255 8.6 0 8.8 8.5 09/14/2005 01:20:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 125 24 104 255 8.5 0 8.8 8.5 09/14/2005 01:30:00 1.1 0.4 1.9 0.4 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 123 5 127 255 8.4 0 8.5 8.3 09/14/2005 01:40:00 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 124 4 129 255 8.3 0 8.5 8.3 09/14/2005 01:50:00 1.7 0.3 2.3 0.7 1.2 0.4 1.9 0.4 0.4 0.1 1.1 0.4 113 6 109 255 8.3 0 8.3 8.3 09/14/2005 02:00:00 2.6 0.3 3.4 1.9 2.3 0.3 3 1.9 1.4 0.4 2.3 0.4 98 5 95 255 8.1 0 8.3 8 09/14/2005 02:10:00 2.3 0.4 3 1.1 1.9 0.5 3 0.7 0.7 0.4 1.9 0.4 98 8 94 255 8.1 0 8.3 8 09/14/2005 02:20:00 1.7 0.3 2.6 1.1 1.2 0.4 2.6 0.4 0.4 0.2 1.5 0.4 101 10 95 255 8 0 8.3 8 09/14/2005 02:30:00 2 0.3 2.6 1.5 1.6 0.3 2.3 0.7 0.6 0.4 1.5 0.4 110 6 103 255 8.1 0 8.3 8 09/14/2005 02:40:00 2.1 0.4 3 0.7 1.7 0.5 2.6 0.4 0.7 0.4 1.5 0.4 110 8 106 255 8.1 0 8.3 8.3 09/14/2005 02:50:00 2 0.3 2.6 1.1 1.5 0.4 2.3 0.4 0.6 0.3 1.9 0.4 111 8 108 255 8.1 0 8.3 8 09/14/2005 03:00:00 2 0.2 2.6 1.5 1.6 0.3 2.3 0.7 0.6 0.3 1.5 0.4 113 7 104 255 8 0 8.3 8 09/14/2005 03:10:00 1.5 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.2 1.1 0.4 114 9 106 255 8 0 8.3 7.8 09/14/2005 03:20:00 1.2 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 133 8 137 255 8 0 8.3 7.8 09/14/2005 03:30:00 1.4 0.3 1.9 0.7 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 117 8 113 255 8 0 8.3 7.8 09/14/2005 03:40:00 0.9 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0 0.7 0.4 125 10 112 255 8 0 8 7.8 09/14/2005 03:50:00 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 136 9 148 255 7.8 0 8 7.8 09/14/2005 04:00:00 1.1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 132 6 131 255 7.8 0 7.8 7.8 09/14/2005 04:10:00 1.4 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 148 20 140 255 7.8 0 7.8 7.8 09/14/2005 04:20:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 137 8 143 255 7.6 0 7.8 7.5 09/14/2005 04:30:00 0.8 0.4 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 126 0 126 255 7.6 0 7.8 7.5 09/14/2005 04:40:00 1.1 0.2 1.5 0.7 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 122 9 126 255 7.6 0 7.8 7.5 09/14/2005 04:50:00 1.1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 97 0 97 255 7.6 0 7.8 7.5 09/14/2005 05:00:00 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 97 0 97 255 7.5 0 7.5 7.5 09/14/2005 05:10:00 1.3 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 107 12 97 255 7.6 0 7.8 7.5 09/14/2005 05:20:00 1.2 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 107 3 111 255 7.6 0 7.8 7.5 09/14/2005 05:30:00 1.3 0.3 1.9 0.7 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 126 5 121 255 7.8 0 7.8 7.8 09/14/2005 05:40:00 1.4 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.5 0.3 1.9 0.4 119 6 119 255 7.8 0 7.8 7.8 09/14/2005 05:50:00 1.6 0.4 2.6 0.7 1.1 0.5 2.3 0.4 0.5 0.2 1.5 0.4 120 10 119 255 7.9 0 8 7.8 09/14/2005 06:00:00 1.6 0.4 2.6 0.7 1 0.5 2.3 0.4 0.4 0.2 1.1 0.4 114 13 115 255 7.9 0 8 7.8 09/14/2005 06:10:00 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 113 17 115 255 8 0 8 7.8 09/14/2005 06:20:00 1.5 0.5 2.3 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 105 10 97 255 8 0 8.3 8 09/14/2005 06:30:00 1.4 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.1 1.1 0.4 106 10 106 255 8.1 0 8.3 8 09/14/2005 06:40:00 1.3 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 115 8 101 255 8.3 0 8.5 8.3 09/14/2005 06:50:00 1.5 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 87 13 91 255 8.4 0 8.5 8.3 09/14/2005 07:00:00 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 102 15 95 255 8.4 0 8.5 8.5 09/14/2005 07:10:00 1.2 0.3 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 129 12 129 255 8.5 0 8.8 8.5 09/14/2005 07:20:00 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 139 0 139 255 8.6 0 8.8 8.5 09/14/2005 07:30:00 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 154 9 158 255 8.7 0 8.8 8.8 09/14/2005 07:40:00 2.4 0.4 3 1.1 2 0.5 2.6 0.7 1.5 0.5 2.6 0.4 154 5 148 255 8.9 0 9 8.8 09/14/2005 07:50:00 2.2 0.5 3 1.1 1.8 0.5 2.6 0.4 1.1 0.6 2.3 0.4 142 10 142 255 8.9 0 9 8.8 09/14/2005 08:00:00 1.3 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 108 14 129 255 9 0 9.3 9 09/14/2005 08:10:00 1.7 0.6 3 0.4 1.2 0.6 2.6 0.4 0.6 0.4 2.3 0.4 116 13 94 255 9.2 0 9.3 9 09/14/2005 08:20:00 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 0.5 0.3 1.9 0.4 105 15 100 255 9.3 0 9.3 9.3 09/14/2005 08:30:00 1 0.6 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 68 16 90 255 9.4 0 9.6 9.3 09/14/2005 08:40:00 0.5 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 71 27 61 255 9.6 0 9.8 9.6 09/14/2005 08:50:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 37 12 20 255 9.8 0 9.8 9.6 09/14/2005 09:00:00 1.9 0.5 3 0.7 1.6 0.6 2.6 0.4 1 0.5 2.3 0.4 45 11 43 255 9.8 0 9.8 9.6 09/14/2005 09:10:00 1.6 0.8 2.6 0.4 1.2 0.7 2.6 0.4 0.9 0.6 2.6 0.4 36 15 47 255 9.8 0 9.8 9.8 09/14/2005 09:20:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 28 15 48 255 10 0 10.1 9.8 09/14/2005 09:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 48 0 48 255 10.1 0 10.3 9.8 09/14/2005 09:40:00 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 93 24 111 255 10.3 0 10.6 10.1 09/14/2005 09:50:00 1.8 0.5 3 0.4 1.4 0.6 2.6 0.4 1.1 0.5 2.3 0.4 89 13 74 255 10.7 0.1 11.1 10.6 09/14/2005 10:00:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 68 22 75 255 11 0 11.1 10.9 09/14/2005 10:10:00 1.8 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 87 15 79 255 11.1 0 11.1 10.9 09/14/2005 10:20:00 2 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.2 0.5 2.6 0.4 102 12 115 255 10.9 0 11.1 10.9 09/14/2005 10:30:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 0.6 0.3 1.9 0.4 102 11 102 255 11.3 0 11.7 11.1 09/14/2005 10:40:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 69 23 42 255 12 0.2 12.5 11.7 09/14/2005 10:50:00 0.6 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 27 22 18 255 12.5 0 12.7 12.2 09/14/2005 11:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 39 22 20 255 12.6 0 12.7 12.5 09/14/2005 11:10:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 60 33 35 255 12.7 0 13 12.5 09/14/2005 11:20:00 1.8 0.5 2.6 0.7 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 31 16 31 255 13 0 13 12.7 09/14/2005 11:30:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.9 0.4 40 47 28 255 13.3 0 13.3 13 09/14/2005 11:40:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 2.3 0.4 356 28 14 255 13.5 0 13.8 13.3 09/14/2005 11:50:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 337 39 351 255 13.5 0 13.8 13.3 09/14/2005 12:00:00 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 1.9 0.4 5 20 30 255 13.7 0 14.1 13.3 09/14/2005 12:10:00 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 313 30 7 255 13.8 0.1 14.6 13.3 09/14/2005 12:20:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 317 21 314 255 13.3 0 13.8 13.3 09/14/2005 12:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 356 49 303 255 13.6 0 14.1 13.3 09/14/2005 12:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 0.7 0.4 44 94 93 255 13.8 0 14.4 13.5 09/14/2005 12:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 111 45 137 255 14.3 0.3 15.2 13.8 09/14/2005 13:00:00 1.5 0.8 3 0.4 1.4 0.8 3 0.4 1.1 0.8 3.4 0.4 321 43 289 255 15 0.1 15.5 14.9 09/14/2005 13:10:00 1.6 0.7 3.8 0.4 1.4 0.7 3.4 0.4 1.3 0.7 3 0.4 260 29 269 255 15.2 0.1 16 15.2 09/14/2005 13:20:00 1.5 0.7 3.8 0.4 1.3 0.6 3 0.4 1 0.6 2.6 0.4 281 49 3 255 16 0.2 16.8 15.7 09/14/2005 13:30:00 1.5 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.3 0.8 3.4 0.4 278 39 302 255 15.5 0.4 16.6 14.9 09/14/2005 13:40:00 1.2 0.6 3 0.4 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 320 22 304 255 15 0 15.5 14.6 09/14/2005 13:50:00 2.2 0.9 3.8 0.4 1.9 1 3.8 0.4 1.5 1 3.8 0.4 303 18 301 255 14.9 0 15.5 14.6 09/14/2005 14:00:00 1.9 0.6 3 0.4 1.6 0.7 3 0.4 1.5 0.6 2.6 0.4 296 15 280 255 14.6 0 15.2 14.6 09/14/2005 14:10:00 2 0.7 3.4 0.4 1.8 0.6 3 0.4 1.7 0.7 3.4 0.4 296 16 294 255 15.5 0.4 16.6 14.9 09/14/2005 14:20:00 1.3 0.9 3.4 0.4 1.2 0.8 3.4 0.4 1.1 0.8 3.4 0.4 255 86 296 255 16.5 0.1 17.1 16.3 09/14/2005 14:30:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 32 53 51 255 16.9 0 17.1 16.8 09/14/2005 14:40:00 1.4 0.7 3 0.4 1.2 0.7 2.6 0.4 1.1 0.5 2.6 0.4 63 36 19 255 17 0 17.1 16.8 09/14/2005 14:50:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 79 41 104 255 16.6 0.3 17.4 16.3 09/14/2005 15:00:00 1.7 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.1 0.6 2.6 0.4 16 27 11 255 16.2 0 16.8 16 09/14/2005 15:10:00 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 0.9 0.5 2.3 0.4 17 24 27 255 15.5 0.1 16 15.2 09/14/2005 15:20:00 1.6 0.8 3.4 0.4 1.4 0.8 3.8 0.4 1 0.6 2.6 0.4 331 43 15 255 15.5 0 15.7 15.5 09/14/2005 15:30:00 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.2 0.5 2.6 0.4 14 17 13 255 15.9 0 16.3 15.7 09/14/2005 15:40:00 1.9 0.8 3.8 0.4 1.6 0.9 3.4 0.4 1.3 0.9 3.4 0.4 354 26 5 255 16.4 0.1 16.8 16 09/14/2005 15:50:00 1.6 0.8 3 0.4 1.4 0.7 3 0.4 1.2 0.6 3 0.4 29 13 3 255 16.1 0.1 16.8 15.7 09/14/2005 16:00:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.4 2.6 0.4 348 47 292 255 15.9 0 16.6 15.7 09/14/2005 16:10:00 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 348 43 286 255 15.9 0 16.3 15.7 09/14/2005 16:20:00 1.9 0.5 3 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 312 17 345 255 15.9 0 16.3 15.7 09/14/2005 16:30:00 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 313 22 292 255 15.8 0 16.3 15.7 09/14/2005 16:40:00 2 0.3 3 1.1 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 297 10 290 255 15.5 0 15.7 15.5 09/14/2005 16:50:00 2.2 0.4 3 1.1 1.9 0.4 3 0.7 1.5 0.5 3 0.4 287 12 268 255 15.6 0 16 15.5 09/14/2005 17:00:00 1.6 0.6 2.6 0.4 1.3 0.6 2.3 0.4 1.1 0.6 2.3 0.4 286 15 293 255 15.4 0.1 16 15.2 09/14/2005 17:10:00 1.5 0.6 2.6 0.4 1.1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 295 23 325 255 15.2 0.2 15.7 15.2 09/14/2005 17:20:00 1.4 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 300 13 288 255 15 0 15.5 14.9 09/14/2005 17:30:00 1.4 0.5 2.6 0.4 0.8 0.4 2.3 0.4 0.7 0.3 1.9 0.4 341 9 350 255 14.6 0 15.2 14.6 09/14/2005 17:40:00 1.6 0.3 2.6 0.7 1 0.4 1.9 0.4 0.6 0.4 2.3 0.4 340 7 328 255 14.2 0.1 14.9 13.8 09/14/2005 17:50:00 1.9 0.5 2.6 0.7 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 304 18 321 255 13.9 0 14.4 13.8 09/14/2005 18:00:00 2 0.4 2.6 1.1 1.8 0.4 2.6 0.7 1.4 0.5 2.3 0.4 292 11 305 255 13.9 0 14.4 13.8 09/14/2005 18:10:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.1 0.5 2.3 0.4 296 12 301 255 13.7 0.1 13.8 13.3 09/14/2005 18:20:00 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.6 0.4 2.3 0.4 304 11 298 255 13 0.2 13.3 12.7 09/14/2005 18:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 321 17 328 255 12.3 0.1 13 11.9 09/14/2005 18:40:00 1.1 0.4 1.9 0.4 0.7 0.3 1.1 0.4 0.4 0.1 1.1 0.4 278 0 278 255 11.8 0 12.5 11.7 09/14/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 278 0 255 255 11.5 0.1 11.7 11.1 09/14/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 278 0 255 255 11 0 11.4 10.9 09/14/2005 19:10:00 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 357 72 64 255 10.5 0 10.9 10.3 09/14/2005 19:20:00 1.5 0.2 1.9 0.7 1.1 0.3 1.5 0.4 0.4 0 0.4 0.4 28 8 26 255 10.1 0 10.3 9.8 09/14/2005 19:30:00 1.1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 26 0 26 255 9.6 0.1 9.8 9.6 09/14/2005 19:40:00 1.3 0.2 1.9 1.1 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 28 6 26 255 9.5 0 9.6 9.6 09/14/2005 19:50:00 1.9 0.3 2.6 1.5 1.6 0.3 2.6 1.1 0.8 0.3 1.9 0.4 54 5 46 255 9.5 0 9.6 9.6 09/14/2005 20:00:00 2.4 0.4 3 1.1 2.1 0.5 3 1.1 1.2 0.5 2.3 0.4 60 8 55 255 9.4 0 9.6 9.3 09/14/2005 20:10:00 2.3 0.4 3.4 1.5 2 0.4 3.4 1.1 1.1 0.4 1.9 0.4 70 7 74 255 9.1 0 9.3 9 09/14/2005 20:20:00 2 0.3 3 1.1 1.7 0.4 2.6 0.7 1 0.4 1.9 0.4 73 10 59 255 9 0 9 9 09/14/2005 20:30:00 1.8 0.3 2.6 1.1 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 64 10 58 255 9.2 0 9.3 9 09/14/2005 20:40:00 2.1 0.5 3.4 0.7 1.8 0.6 3 0.4 1 0.5 2.3 0.4 70 9 69 255 9.4 0 9.6 9.3 09/14/2005 20:50:00 1.7 0.5 2.6 0.7 1.3 0.5 2.3 0.4 0.7 0.4 1.9 0.4 69 7 81 255 9.5 0 9.6 9.3 09/14/2005 21:00:00 2.1 0.5 3.4 1.1 1.8 0.5 3 0.4 1.1 0.5 2.3 0.4 76 9 72 255 9.7 0 9.8 9.6 09/14/2005 21:10:00 2 0.5 3.4 1.1 1.7 0.6 3 0.4 1 0.6 2.6 0.4 77 15 69 255 10 0 10.1 9.8 09/14/2005 21:20:00 3.3 0.6 4.9 1.5 3.2 0.6 4.9 1.5 2.2 0.6 3.4 0.7 73 13 63 255 10.3 0 10.6 9.8 09/14/2005 21:30:00 2.8 0.4 4.2 1.9 2.6 0.5 3.8 1.1 1.6 0.6 3.4 0.4 70 11 68 255 10.5 0 10.6 10.6 09/14/2005 21:40:00 2.7 0.4 3.8 1.1 2.5 0.4 3.4 1.1 1.5 0.4 2.6 0.4 83 10 69 255 10.6 0 10.6 10.6 09/14/2005 21:50:00 2.8 0.5 4.2 1.9 2.5 0.6 3.8 1.5 1.6 0.6 3 0.4 93 11 68 255 10.4 0 10.6 10.3 09/14/2005 22:00:00 3.8 0.6 5.3 2.3 3.7 0.6 4.9 2.3 2.7 0.6 4.2 1.5 81 9 83 255 10.3 0 10.6 10.3 09/14/2005 22:10:00 4.4 0.8 6.5 2.3 4.3 0.8 6.5 2.3 3.2 0.8 5.7 1.1 83 12 74 255 10.8 0.1 11.1 10.6 09/14/2005 22:20:00 4.7 0.9 8 2.6 4.6 1 8 2.6 3.7 1 6.5 1.5 68 13 59 255 11.3 0 11.7 11.1 09/14/2005 22:30:00 3.9 0.8 5.7 1.5 3.9 0.8 6.1 1.9 3.1 0.8 5.7 0.7 62 14 74 255 11.7 0 11.7 11.4 09/14/2005 22:40:00 3.9 0.8 6.1 2.3 3.9 0.9 6.5 1.9 2.9 0.8 5.3 0.4 72 15 83 255 11.7 0 11.9 11.7 09/14/2005 22:50:00 4 0.7 6.1 2.3 3.9 0.7 6.1 2.3 3 0.7 4.9 1.1 81 11 78 255 11.3 0.1 11.7 11.1 09/14/2005 23:00:00 4.6 0.8 6.8 2.6 4.5 0.8 6.8 2.3 3.4 0.8 5.3 1.5 86 12 68 255 11.3 0 11.4 11.4 09/14/2005 23:10:00 4.6 0.7 6.8 3 4.5 0.8 6.8 3 3.3 0.8 5.7 1.9 85 11 86 255 11.4 0 11.7 11.4 09/14/2005 23:20:00 4.2 0.8 6.5 1.9 4.1 0.8 6.1 2.3 3 0.9 5.7 1.1 81 11 82 255 11.4 0 11.7 11.4 09/14/2005 23:30:00 3.7 0.9 6.5 1.5 3.6 0.9 6.5 1.1 2.9 0.9 5.3 1.1 66 13 68 255 11.3 0 11.4 11.1 09/14/2005 23:40:00 4.3 0.7 6.5 2.6 4.2 0.7 6.5 2.6 3.3 0.8 5.3 1.1 66 14 65 255 11.5 0 11.7 11.4 09/14/2005 23:50:00 3.1 1.2 6.1 0.7 2.9 1.2 5.7 0.7 2.3 1 4.9 0.4 64 27 64 255 11.5 0 11.7 11.4 09/15/2005 00:00:00 2.9 0.6 4.9 1.5 2.8 0.6 4.6 1.1 2.2 0.6 4.2 0.4 44 17 62 255 11 0 11.4 10.9 09/15/2005 00:10:00 3.7 1.2 6.8 1.5 3.5 1.3 6.5 1.1 2.6 1.1 5.3 0.7 64 15 46 255 10.9 0 11.1 10.9 09/15/2005 00:20:00 4.6 0.7 6.5 2.6 4.5 0.7 6.1 2.6 3.3 0.8 5.3 1.1 79 10 85 255 11 0 11.1 10.9 09/15/2005 00:30:00 4.4 0.9 7.6 2.6 4.3 0.9 7.6 2.3 3.4 1 6.8 1.5 84 10 91 255 10.6 0 10.9 10.6 09/15/2005 00:40:00 5.1 0.6 6.8 3.4 5.1 0.7 6.8 3 4.1 0.8 7.2 2.3 75 10 52 255 10.3 0.1 10.6 10.1 09/15/2005 00:50:00 4.4 0.8 6.5 2.6 4.3 0.9 6.1 2.3 3.4 0.9 5.7 1.1 83 12 89 255 10 0 10.1 9.8 09/15/2005 01:00:00 4.3 0.7 6.1 2.3 4.1 0.7 6.1 2.6 3.4 0.6 4.9 2.3 96 10 108 255 9.8 0 9.8 9.6 09/15/2005 01:10:00 4.5 0.8 6.8 2.6 4.4 0.8 6.5 2.3 3.4 0.8 6.1 1.5 92 12 73 255 9.6 0.1 9.8 9.3 09/15/2005 01:20:00 4.9 0.7 6.5 3 4.8 0.6 6.5 3 3.6 0.8 5.7 1.5 83 9 88 255 9.4 0 9.6 9.3 09/15/2005 01:30:00 4.3 0.8 6.8 1.9 4.2 0.8 6.5 1.9 3.1 0.9 5.3 0.4 82 12 89 255 9.4 0 9.6 9 09/15/2005 01:40:00 4.8 0.7 7.2 3 4.7 0.7 6.5 2.6 3.7 0.8 6.1 1.5 86 12 86 255 9 0 9.3 9 09/15/2005 01:50:00 4.6 0.7 6.5 3 4.5 0.7 6.5 2.6 3.5 0.7 5.7 1.5 93 10 93 255 9.1 0 9.3 9 09/15/2005 02:00:00 4.1 0.5 5.3 3 3.9 0.5 5.3 2.6 3.1 0.6 4.6 1.5 101 9 90 255 8.9 0 9 8.8 09/15/2005 02:10:00 4.3 0.6 6.5 2.3 4.2 0.6 6.1 2.3 3.4 0.7 5.3 1.1 102 10 109 255 8.7 0.1 9 8.5 09/15/2005 02:20:00 5.1 0.7 6.5 3 5 0.7 6.8 3 3.9 0.8 6.1 1.9 104 10 108 255 8.4 0 8.5 8.5 09/15/2005 02:30:00 4.9 0.8 6.5 2.6 4.8 0.8 6.8 2.3 3.8 0.8 5.7 1.9 106 13 115 255 8.5 0 8.8 8.5 09/15/2005 02:40:00 5.2 0.8 7.2 3 5.1 0.8 7.2 2.6 3.8 0.8 6.1 1.9 102 13 122 255 8.5 0 8.8 8.5 09/15/2005 02:50:00 5.4 0.7 7.6 3.4 5.3 0.7 7.6 3.4 4.1 0.9 6.1 1.9 101 12 84 255 8.7 0 8.8 8.8 09/15/2005 03:00:00 5.4 1 7.6 3 5.3 1 8 3 4.1 1 6.8 1.9 105 13 95 255 8.7 0 9 8.5 09/15/2005 03:10:00 6.3 1 9.1 3.8 6.2 1 8.8 3.8 4.9 1 8 1.9 107 13 96 255 8.6 0 8.8 8.5 09/15/2005 03:20:00 6.5 1.2 9.9 3.8 6.5 1.2 9.5 3.4 5.1 1.2 8.8 1.9 104 16 104 255 8.9 0 9 8.8 09/15/2005 03:30:00 6.3 1 8.8 3.4 6.2 1 8.8 2.6 4.8 1 7.2 2.3 106 14 104 255 9 0 9.3 9 09/15/2005 03:40:00 4.3 1 6.8 1.5 4.2 1 6.8 1.9 3.2 1 6.5 0.4 99 15 84 255 8.9 0 9 8.8 09/15/2005 03:50:00 4.7 0.8 7.2 2.6 4.6 0.8 6.8 2.6 3.7 0.7 6.1 1.9 94 13 76 255 8.9 0 9 8.8 09/15/2005 04:00:00 5.5 1 8.8 3 5.4 1 8.4 3 4.2 1 8 2.3 99 13 89 255 8.9 0 9 8.8 09/15/2005 04:10:00 6.1 1.3 9.9 2.6 6 1.3 9.9 3 4.9 1.3 9.5 1.9 94 15 106 255 9.1 0 9.3 9 09/15/2005 04:20:00 6 1 8.8 3.4 5.9 1 8.8 3 4.7 0.9 7.2 2.3 103 15 111 255 9 0.2 9.6 8.8 09/15/2005 04:30:00 6.1 1 9.5 3.8 6 1 9.5 3.8 4.8 1 8 2.6 103 11 105 255 8.7 0 9 8.5 09/15/2005 04:40:00 5.7 1 8.4 3 5.6 1 8 3.4 4.4 1.1 7.2 1.9 106 14 112 255 8.6 0 8.8 8.5 09/15/2005 04:50:00 4.9 1.5 9.9 1.1 4.8 1.5 10.3 0.7 3.8 1.3 7.6 1.5 101 21 91 255 8.6 0 8.8 8.5 09/15/2005 05:00:00 5.9 1.3 9.5 2.3 5.8 1.3 9.1 1.5 4.7 1.3 8.4 1.1 102 14 105 255 8.6 0 8.8 8.5 09/15/2005 05:10:00 6.1 1 8 2.3 6 1 8.8 3 4.9 1 8 1.9 97 12 106 255 9.1 0.2 9.6 8.8 09/15/2005 05:20:00 6.1 1.1 9.9 3 6 1.2 9.5 2.3 5 1.2 8 2.3 107 17 95 255 9.6 0 9.8 9.6 09/15/2005 05:30:00 4.6 1.5 8 1.9 4.4 1.5 8 1.5 3.6 1.4 8.4 1.1 105 22 97 255 9.4 0 9.6 9.3 09/15/2005 05:40:00 3.9 1 7.2 1.5 3.6 1 7.2 1.5 2.9 0.8 5.7 0.7 110 19 139 255 9 0 9.3 8.8 09/15/2005 05:50:00 3.6 0.9 6.1 1.9 3.4 1 6.1 1.5 2.8 1 4.9 0.4 107 22 106 255 9 0 9 9 09/15/2005 06:00:00 3 0.8 5.3 1.5 2.6 0.9 4.9 0.7 2 0.7 3.8 0.4 110 22 66 255 8.9 0 9 8.8 09/15/2005 06:10:00 4.1 0.8 5.7 2.3 3.9 0.8 5.7 2.3 3.5 0.8 5.3 1.5 128 15 142 255 8.6 0.1 9 8.5 09/15/2005 06:20:00 4.3 0.6 6.1 2.3 4 0.7 6.1 1.9 3.3 0.7 4.9 1.5 128 11 127 255 8.7 0 8.8 8.5 09/15/2005 06:30:00 4.5 0.8 6.1 2.3 4.3 0.9 6.1 1.9 3.4 0.8 5.3 1.1 128 13 132 255 8.7 0 8.8 8.5 09/15/2005 06:40:00 4.5 0.8 6.5 2.6 4.4 0.8 6.5 2.3 3.5 0.8 6.1 1.9 125 12 123 255 8.9 0 9 8.5 09/15/2005 06:50:00 4.6 1 7.2 1.9 4.5 1 6.8 1.1 3.6 0.9 6.5 1.5 121 16 118 255 9.1 0 9.3 9 09/15/2005 07:00:00 4.5 0.7 6.5 2.6 4.4 0.7 6.1 2.6 3.4 0.7 5.3 1.1 102 15 81 255 9.4 0 9.6 9.3 09/15/2005 07:10:00 4.6 0.8 7.6 3 4.5 0.8 7.6 2.6 3.4 0.8 5.3 0.7 92 11 93 255 9.6 0.1 10.1 9.6 09/15/2005 07:20:00 4.2 0.7 6.1 2.3 4 0.8 5.7 1.9 3.2 0.7 4.9 1.1 101 12 90 255 10 0 10.1 9.8 09/15/2005 07:30:00 4.2 1 6.8 1.5 4 1.1 6.5 1.1 3.4 1.1 6.1 1.1 111 20 105 255 9.9 0 10.1 9.8 09/15/2005 07:40:00 4.1 1.1 6.8 1.9 3.8 1.1 6.8 1.1 3.2 0.9 5.3 1.1 129 15 113 255 9.8 0 9.8 9.8 09/15/2005 07:50:00 4.7 1 7.2 2.3 4.6 1 6.5 1.9 3.7 0.8 6.5 1.5 127 15 142 255 9.8 0 9.8 9.8 09/15/2005 08:00:00 4.6 0.8 6.5 2.6 4.4 0.8 6.5 2.3 3.7 0.7 5.7 2.3 124 15 111 255 10 0 10.1 9.8 09/15/2005 08:10:00 3.9 0.9 6.1 1.9 3.7 0.9 6.1 1.1 3.1 0.9 5.7 0.7 111 16 122 255 10.2 0 10.3 9.8 09/15/2005 08:20:00 2.9 0.8 5.3 1.1 2.7 0.8 4.9 0.7 2.3 0.7 4.9 0.7 106 21 136 255 10.5 0 10.6 10.3 09/15/2005 08:30:00 3.6 0.6 5.3 1.5 3.3 0.6 4.6 1.5 2.8 0.6 4.6 1.5 106 17 99 255 10.5 0 10.9 10.6 09/15/2005 08:40:00 3.8 0.9 6.1 1.5 3.6 1 5.7 0.7 3.1 0.7 4.9 1.5 85 20 84 255 10.9 0 11.1 10.6 09/15/2005 08:50:00 4.7 1 8 2.6 4.6 1 8 2.3 3.7 1 7.6 1.1 72 21 64 255 11.3 0 11.4 11.1 09/15/2005 09:00:00 5.2 1.1 8.8 2.6 5.1 1.2 8.4 2.3 4.1 1.2 8.4 1.1 76 21 82 255 11.4 0 11.7 11.4 09/15/2005 09:10:00 5.2 1.1 8 2.3 5.1 1.2 7.6 2.3 4.3 1.1 8 1.5 79 16 84 255 11.5 0 11.7 11.4 09/15/2005 09:20:00 4.5 1 7.2 2.3 4.4 1.1 6.8 1.9 3.5 1 6.1 0.4 86 17 76 255 11.4 0 11.7 11.4 09/15/2005 09:30:00 5.2 1.1 8.4 2.6 5 1.2 8 3 4.3 1.1 7.2 1.1 69 17 69 255 11.4 0 11.7 11.4 09/15/2005 09:40:00 4.8 1.1 7.6 1.5 4.7 1.1 7.2 1.5 3.9 1.1 6.1 0.4 85 17 85 255 11.6 0 11.7 11.4 09/15/2005 09:50:00 5 1.1 8.4 2.3 4.8 1.1 8.8 1.5 3.9 1.1 7.6 1.1 91 15 73 255 11.6 0 11.7 11.4 09/15/2005 10:00:00 4.8 1.3 9.1 1.9 4.7 1.3 9.1 1.9 3.8 1.1 7.2 1.1 67 19 80 255 11.8 0.1 12.2 11.7 09/15/2005 10:10:00 5.2 1.4 9.1 2.3 5.1 1.5 9.1 1.9 4 1.3 8 1.1 60 21 77 255 12.6 0.2 13 12.2 09/15/2005 10:20:00 4.3 0.9 7.2 1.9 4.1 1 7.2 1.5 3.6 1 6.1 1.1 82 23 66 255 13.2 0 13.3 13 09/15/2005 10:30:00 3.8 1.2 8 1.1 3.6 1.3 8.4 0.4 3 1.3 7.2 0.4 91 24 124 255 13 0 13.3 12.7 09/15/2005 10:40:00 3.7 0.7 5.3 2.3 3.5 0.8 5.3 1.1 3 0.8 4.9 0.7 78 22 59 255 13.3 0 13.3 13 09/15/2005 10:50:00 3.6 1 7.2 1.9 3.4 1.1 7.6 1.5 2.9 1.1 7.2 0.7 66 20 32 255 13.3 0 13.3 13.3 09/15/2005 11:00:00 3.9 0.9 7.6 1.9 3.7 1 7.6 1.5 3.3 0.8 5.7 1.5 65 20 34 255 13.3 0 13.3 13.3 09/15/2005 11:10:00 6.4 2 11.5 3 6.2 2.1 11.8 2.3 5.2 1.8 11.8 1.1 44 19 46 255 13.5 0.1 13.8 13.3 09/15/2005 11:20:00 6.7 1.2 10.3 3.4 6.6 1.2 11.1 3.8 5.7 1.3 9.5 2.3 47 17 48 255 13.9 0 14.1 13.5 09/15/2005 11:30:00 6.4 1.7 10.7 2.6 6.3 1.7 10.7 3 5.3 1.7 9.9 1.9 51 19 64 255 13.4 0 13.5 13 09/15/2005 11:40:00 6.1 2.1 12.2 2.3 6 2 12.2 2.6 5.1 1.8 10.7 1.9 52 22 41 255 13.3 0 13.5 13 09/15/2005 11:50:00 6.7 1.6 11.1 3 6.6 1.7 11.1 2.6 5.4 1.6 9.9 1.9 46 20 28 255 13.8 0 13.8 13.5 09/15/2005 12:00:00 7.1 2.2 13 3 7 2.3 13 3 6 2.1 13 1.5 45 16 34 255 14 0 14.4 13.8 09/15/2005 12:10:00 4.3 1.3 9.5 1.9 4.1 1.4 9.5 1.1 3.5 1.2 8 0.7 81 27 67 255 13.8 0.2 14.4 13.5 09/15/2005 12:20:00 3.4 1 5.7 0.4 3.1 1.1 4.9 0.4 2.8 1.1 4.9 0.4 70 18 81 255 13.5 0 13.5 13.3 09/15/2005 12:30:00 4.2 1.1 8.8 2.3 3.9 1.2 8.4 1.5 3.4 0.9 6.5 1.1 68 30 26 255 13.4 0 13.5 13.3 09/15/2005 12:40:00 4.7 1.8 9.1 0.4 4.5 1.9 9.1 0.4 3.5 1.7 8 0.4 23 22 14 255 13.7 0 13.8 13.5 09/15/2005 12:50:00 6.6 2.9 13.3 1.1 6.5 3.1 13.7 0.7 5.1 2.7 12.2 0.4 26 22 14 255 13.7 0 13.8 13.5 09/15/2005 13:00:00 6.2 1.3 9.9 2.6 6.2 1.5 10.3 1.5 4.2 1.5 8 1.1 5 20 353 255 13.1 0.2 13.5 12.7 09/15/2005 13:10:00 6.9 1.6 11.5 2.3 6.9 1.7 11.5 2.3 5.3 1.6 10.3 0.7 16 17 3 255 12.7 0 12.7 12.5 09/15/2005 13:20:00 7.2 1.5 11.5 3.8 7.2 1.5 11.5 3 5.3 1.6 10.7 1.5 19 16 18 255 12.3 0 12.5 12.2 09/15/2005 13:30:00 7.5 1.4 11.1 3.4 7.5 1.4 11.5 3.4 5.5 1.7 8.8 1.1 16 13 33 255 12.4 0 12.5 12.2 09/15/2005 13:40:00 8.1 1.8 13 4.6 8.1 1.8 12.2 4.2 6.4 1.8 10.7 2.3 20 13 358 255 12.7 0 12.7 12.5 09/15/2005 13:50:00 7.8 1.7 11.5 3.4 7.7 1.7 11.5 3.8 6 1.7 11.1 1.9 20 15 52 255 13 0 13.3 12.7 09/15/2005 14:00:00 7.7 1.5 11.8 3.4 7.7 1.6 11.8 3.4 6 1.6 11.1 2.3 19 15 355 255 13.4 0 13.5 13.3 09/15/2005 14:10:00 8.2 1.7 13.3 3.8 8.1 1.7 13.3 3.8 6.2 1.7 11.8 1.9 18 13 3 255 13.5 0 13.5 13.3 09/15/2005 14:20:00 8.2 1.8 13 3.8 8.1 1.9 13 3.4 6.2 2.3 11.5 1.9 19 13 28 255 13.1 0.2 13.5 12.7 09/15/2005 14:30:00 8.4 1.5 11.8 3.8 8.3 1.5 11.8 4.2 6.5 1.7 11.5 2.3 20 12 11 255 12.6 0.1 12.7 12.2 09/15/2005 14:40:00 7.1 2 12.6 3.8 7.1 1.9 12.6 3.8 5.6 1.8 11.1 1.9 20 13 23 255 12.3 0 12.5 12.2 09/15/2005 14:50:00 7.9 1.6 13 3.8 7.9 1.6 13.3 4.2 6.3 1.8 11.5 2.3 18 12 6 255 12 0.1 12.2 11.9 09/15/2005 15:00:00 6.5 1.3 11.1 3 6.5 1.3 11.5 3.4 5.2 1.4 9.5 1.9 24 13 15 255 11.8 0 11.9 11.7 09/15/2005 15:10:00 5.6 1.4 11.1 2.6 5.6 1.3 11.5 2.6 4.6 1.3 9.1 1.9 34 17 14 255 11.7 0 11.9 11.7 09/15/2005 15:20:00 3.6 0.9 6.8 1.1 3.7 0.9 6.5 1.1 2.8 0.9 6.1 0.7 54 22 35 255 11.7 0 11.9 11.7 09/15/2005 15:30:00 3.2 0.7 5.3 1.5 3.4 0.6 5.3 1.9 2.6 0.8 4.9 0.7 92 15 97 255 11.5 0 11.7 11.4 09/15/2005 15:40:00 3.6 0.8 5.7 1.5 3.6 0.8 5.7 2.3 2.9 0.8 4.9 1.1 82 12 81 255 11.7 0 11.9 11.4 09/15/2005 15:50:00 4 1.1 6.5 1.5 4 1.1 6.5 1.5 3.2 1.1 6.1 0.7 83 17 100 255 12.1 0 12.2 11.9 09/15/2005 16:00:00 3.8 1 7.2 1.5 3.8 1 6.8 1.5 3.1 1 6.5 0.4 72 18 78 255 12.3 0 12.5 12.2 09/15/2005 16:10:00 4.3 1 7.6 1.5 4.3 1 7.2 2.3 3.6 1 7.2 1.1 76 16 91 255 12.4 0 12.5 12.2 09/15/2005 16:20:00 5.6 1.1 8 3.4 5.6 1.1 8.8 2.3 4.6 1.3 8 1.5 70 16 76 255 12.7 0.1 12.7 12.5 09/15/2005 16:30:00 4.1 1 6.5 1.5 4 1.1 6.5 0.7 3.4 0.9 6.1 1.1 65 17 49 255 12.8 0 12.7 12.7 09/15/2005 16:40:00 5.3 1.5 10.3 2.3 5.4 1.5 9.9 2.3 4.3 1.4 9.5 1.5 66 18 69 255 12.9 0 13 12.7 09/15/2005 16:50:00 4.6 1.1 7.2 1.9 4.5 1.1 6.8 1.5 3.8 1.2 6.8 0.7 72 17 100 255 13.1 0 13.3 13 09/15/2005 17:00:00 5.2 1.2 8.8 1.9 5.1 1.2 8.8 1.9 4.2 1.1 7.2 1.1 60 22 63 255 13.3 0 13.3 13 09/15/2005 17:10:00 4.8 1.1 8.4 2.6 4.8 1.1 8.8 2.6 3.9 1.1 8 1.1 70 17 70 255 13.4 0 13.5 13.3 09/15/2005 17:20:00 5.9 1.5 9.5 2.6 5.8 1.5 9.9 2.3 4.7 1.3 8.4 1.9 59 17 73 255 13.5 0 13.5 13.3 09/15/2005 17:30:00 5.4 1.1 8.8 2.6 5.2 1.1 8.4 2.6 4.5 1.1 7.6 1.9 68 16 61 255 13.5 0 13.8 13.3 09/15/2005 17:40:00 4.1 0.9 6.8 1.9 3.9 1 6.5 1.5 3.5 1 6.1 0.7 66 17 104 255 13.3 0 13.3 13.3 09/15/2005 17:50:00 4.4 1.1 7.6 1.5 4.2 1.1 7.2 1.5 3.5 1.1 7.2 1.1 70 18 79 255 13.1 0 13.3 13 09/15/2005 18:00:00 4.8 1.1 7.2 2.3 4.7 1.1 7.6 2.3 4 1.1 6.8 1.5 74 17 94 255 13 0 13.3 12.7 09/15/2005 18:10:00 4.4 1.2 7.2 1.9 4.3 1.2 7.6 1.9 3.6 1.1 6.1 0.7 83 16 91 255 13.1 0 13.3 13 09/15/2005 18:20:00 4.6 1.1 7.2 2.3 4.6 1.1 7.2 2.3 3.9 1 7.2 1.1 84 15 89 255 13.3 0 13.3 13 09/15/2005 18:30:00 4.1 1 6.8 1.9 4 1.1 6.8 1.5 3.4 1.1 6.1 1.1 62 17 62 255 13.1 0 13.3 13 09/15/2005 18:40:00 4.3 1 7.2 1.5 4.3 1 6.8 1.5 3.5 1 6.8 1.1 78 22 77 255 12.9 0 13 12.7 09/15/2005 18:50:00 3.4 1 6.1 0.7 3.2 1 5.7 0.7 2.7 1 5.3 0.7 105 18 115 255 12.9 0.1 13.3 12.7 09/15/2005 19:00:00 4.3 1.2 7.2 1.5 4.1 1.2 7.2 0.7 3.5 1.1 6.1 1.1 96 17 74 255 12.6 0 12.7 12.5 09/15/2005 19:10:00 4.7 0.9 6.5 2.3 4.6 0.9 6.8 2.3 3.7 0.9 6.1 1.5 94 15 106 255 12.8 0 13 12.7 09/15/2005 19:20:00 4.5 1.3 6.8 1.1 4.4 1.3 6.8 0.4 3.6 1.2 6.1 0.4 88 14 97 255 12.8 0 13 12.7 09/15/2005 19:30:00 4.1 0.8 6.1 1.9 4 0.8 6.1 1.5 3.4 0.7 5.3 1.5 90 15 69 255 12.8 0 12.7 12.7 09/15/2005 19:40:00 4.1 0.7 5.7 1.9 4 0.8 6.1 1.9 3.3 0.7 5.3 1.5 91 13 100 255 12.8 0 12.7 12.7 09/15/2005 19:50:00 3.4 0.9 5.7 1.1 3.2 1 5.7 0.7 2.7 0.9 4.9 0.7 88 12 102 255 12.5 0.1 12.7 12.5 09/15/2005 20:00:00 3.8 0.8 7.2 2.3 3.7 0.8 6.8 1.9 2.9 0.9 6.5 1.1 79 12 67 255 12.2 0 12.5 12.2 09/15/2005 20:10:00 4.3 0.9 7.2 1.9 4.2 1 6.5 1.5 3.4 1 6.1 1.1 69 20 80 255 12.3 0 12.5 12.2 09/15/2005 20:20:00 4.6 1 6.8 2.3 4.5 1 6.8 2.3 3.7 1 6.5 1.5 68 19 83 255 12.7 0 12.7 12.5 09/15/2005 20:30:00 4.2 0.8 7.2 1.9 4.1 0.8 6.5 2.3 3.3 0.8 5.7 1.9 68 16 69 255 12.8 0 12.7 12.7 09/15/2005 20:40:00 5 1 7.6 2.6 4.9 1 7.2 2.6 4 1 6.5 1.5 76 13 69 255 12.7 0 12.7 12.5 09/15/2005 20:50:00 5.1 0.8 7.2 2.6 5 0.9 7.2 2.6 4.2 1 6.5 1.9 64 13 62 255 12.8 0 13 12.7 09/15/2005 21:00:00 4.1 0.7 6.1 2.3 3.9 0.7 5.3 1.9 3.4 0.7 4.9 1.5 73 11 58 255 12.9 0 13 12.7 09/15/2005 21:10:00 4.2 0.8 6.8 1.9 4.1 0.9 6.8 1.9 3.4 0.8 6.5 1.5 65 15 89 255 12.6 0 12.7 12.5 09/15/2005 21:20:00 4.6 0.8 6.8 2.6 4.5 0.8 6.8 2.3 3.7 0.8 6.5 1.9 64 12 30 255 12.6 0 12.7 12.5 09/15/2005 21:30:00 5.2 1 8 2.3 5.2 1 7.6 2.6 4.2 1.1 6.8 1.9 64 15 72 255 12.9 0 13 12.7 09/15/2005 21:40:00 4.7 1 8 1.5 4.6 1.1 8.4 0.7 3.7 1.1 6.1 0.4 73 17 94 255 12.9 0 13 12.7 09/15/2005 21:50:00 5 1 7.6 2.6 4.9 1 7.2 1.9 4.1 1 6.8 1.5 81 12 82 255 12.8 0 13 12.7 09/15/2005 22:00:00 4.5 1 6.8 1.9 4.4 1 7.2 1.9 3.5 1 6.1 1.1 82 17 85 255 12.9 0 13 12.7 09/15/2005 22:10:00 4.8 1.1 8.4 2.3 4.7 1.1 8 1.9 3.6 1.1 6.5 1.1 64 18 41 255 12.9 0 13 12.7 09/15/2005 22:20:00 4.3 1.1 8.4 2.3 4.1 1.1 8.4 1.9 3.3 1.1 6.8 0.4 84 20 86 255 13 0.1 13.3 12.5 09/15/2005 22:30:00 4.4 0.9 7.6 2.6 4.3 1 7.6 2.3 3.5 1 7.6 1.1 86 17 74 255 12.4 0 12.7 12.2 09/15/2005 22:40:00 4 0.9 6.8 1.5 3.9 1 6.8 1.9 3.3 0.8 5.7 1.5 94 16 94 255 12.2 0 12.5 11.9 09/15/2005 22:50:00 4 0.8 6.5 1.9 3.8 0.7 6.1 1.9 3 0.8 5.3 0.7 86 18 67 255 11.9 0 12.2 11.9 09/15/2005 23:00:00 3.2 0.8 5.3 1.5 3.1 0.9 4.9 1.1 2.4 0.8 4.2 0.4 102 17 93 255 11.8 0 11.9 11.7 09/15/2005 23:10:00 3.2 0.6 5.3 1.5 3 0.7 4.9 1.5 2.4 0.6 4.6 1.1 94 15 71 255 11.7 0 11.9 11.7 09/15/2005 23:20:00 3 0.8 4.9 0.7 2.8 0.8 4.6 0.4 2.3 0.7 4.2 0.7 101 13 83 255 11.8 0 11.9 11.7 09/15/2005 23:30:00 3.1 0.9 5.3 0.7 2.9 1 5.3 0.4 2.3 0.8 4.6 0.7 88 21 83 255 11.7 0 11.9 11.7 09/15/2005 23:40:00 3.5 0.9 6.1 1.5 3.2 1 6.1 0.7 2.7 0.9 4.9 0.7 90 16 90 255 11.7 0 11.7 11.7 09/15/2005 23:50:00 4.3 1.2 8.8 2.3 4.2 1.2 8.8 1.5 3.4 1.1 6.8 0.7 70 20 68 255 11.9 0.1 11.9 11.7 09/16/2005 00:00:00 3.9 1 6.5 1.9 3.7 1.1 6.5 1.1 3 1 6.5 1.1 73 17 68 255 11.9 0 12.2 11.7 09/16/2005 00:10:00 4.2 1 6.8 1.9 4.2 1 6.8 1.9 3.3 1.1 6.5 0.4 74 15 69 255 12.1 0 12.5 11.9 09/16/2005 00:20:00 4.3 1.1 7.2 2.3 4.2 1.2 7.6 1.1 3.3 1.1 6.8 1.1 77 19 45 255 12.4 0 12.7 12.2 09/16/2005 00:30:00 4 0.9 6.5 2.3 3.9 0.9 6.1 1.5 3 0.9 5.7 1.1 89 15 108 255 11.9 0.1 12.2 11.7 09/16/2005 00:40:00 4.1 1 6.8 1.5 3.9 1.1 6.5 1.1 3.3 1 6.1 0.7 83 13 93 255 11.7 0 11.9 11.7 09/16/2005 00:50:00 3.3 0.9 6.1 1.5 3.1 1 6.1 0.7 2.7 0.8 4.9 0.7 106 19 88 255 11.7 0 11.9 11.7 09/16/2005 01:00:00 3.5 0.7 5.3 1.9 3.4 0.8 5.3 1.9 2.7 0.6 4.6 1.5 115 15 123 255 11.3 0 11.7 11.1 09/16/2005 01:10:00 3.7 0.7 5.7 2.3 3.6 0.7 5.7 1.9 2.9 0.7 5.3 1.5 97 13 71 255 11.1 0 11.1 11.1 09/16/2005 01:20:00 3.7 0.8 6.5 1.9 3.6 0.8 6.1 1.5 2.7 0.9 4.6 0.7 81 22 102 255 11.2 0 11.4 11.1 09/16/2005 01:30:00 4.6 1 8 1.9 4.6 1 8.4 2.3 3.5 1.1 7.2 0.4 68 14 77 255 11.3 0 11.7 11.1 09/16/2005 01:40:00 5 0.9 7.2 3 4.9 0.9 7.2 2.6 3.9 1 6.8 1.1 74 13 73 255 11.5 0 11.7 11.4 09/16/2005 01:50:00 4.4 0.8 6.5 1.9 4.3 0.8 6.5 2.3 3.4 0.8 5.7 1.5 79 13 86 255 11.5 0 11.7 11.4 09/16/2005 02:00:00 5.2 1.1 8.4 2.6 5.1 1.2 8.4 2.3 3.9 1.2 8.4 1.1 78 16 92 255 11.6 0 11.7 11.4 09/16/2005 02:10:00 5.5 1.1 8.4 3 5.5 1.1 8.4 3 4.2 1.1 7.6 1.9 70 16 74 255 11.8 0 11.9 11.7 09/16/2005 02:20:00 5.8 1 8.4 3 5.7 1 8.4 2.6 4.5 1.1 7.2 1.5 75 15 68 255 11.8 0 11.9 11.7 09/16/2005 02:30:00 5.8 1.1 9.1 3 5.7 1.1 9.1 2.6 4.5 1.1 7.2 1.5 71 15 64 255 12 0 11.9 11.9 09/16/2005 02:40:00 6.4 1 8.8 3.8 6.3 1.1 8.8 3.4 5.1 1.2 8.4 1.9 77 13 74 255 11.9 0 12.2 11.7 09/16/2005 02:50:00 5.4 1 8 2.3 5.3 1.1 8 1.9 4.2 0.9 6.8 1.9 85 14 84 255 11.7 0 11.9 11.7 09/16/2005 03:00:00 5.1 1 7.6 2.6 5 1 7.6 2.3 3.9 1 7.2 1.5 79 15 86 255 11.7 0 11.9 11.7 09/16/2005 03:10:00 5.2 1.1 8.4 2.3 5.2 1 8 2.3 4 1.1 6.8 1.1 83 14 95 255 11.8 0 11.9 11.7 09/16/2005 03:20:00 4.8 1 7.6 1.5 4.6 1 7.6 1.9 3.8 1 7.2 1.5 89 17 80 255 11.8 0 11.9 11.7 09/16/2005 03:30:00 5.1 0.8 7.6 3 4.9 0.8 7.2 2.6 4 0.9 6.1 2.3 80 14 71 255 11.7 0 11.9 11.7 09/16/2005 03:40:00 5.6 1.1 8.8 3 5.5 1.2 8.4 2.3 4.5 1.1 6.8 2.3 80 15 90 255 11.7 0 11.7 11.7 09/16/2005 03:50:00 5.6 1.1 9.1 3 5.5 1.1 8.8 3 4.3 1.2 9.5 1.1 80 15 86 255 11.7 0 11.7 11.7 09/16/2005 04:00:00 5.2 1 7.6 1.9 5.2 1.1 8 1.9 4.1 1 6.8 1.9 87 13 81 255 11.7 0 11.9 11.7 09/16/2005 04:10:00 5.3 1 8 2.3 5.2 1 7.6 2.6 4.1 1.1 6.8 1.1 87 15 86 255 11.7 0 11.7 11.7 09/16/2005 04:20:00 4.9 1 7.2 2.6 4.8 1 7.2 2.6 3.7 0.9 6.8 0.7 91 15 95 255 11.7 0 11.9 11.7 09/16/2005 04:30:00 5.8 1 8.8 3.4 5.7 1 8.4 3 4.6 1 7.6 1.9 82 13 89 255 11.7 0 11.9 11.7 09/16/2005 04:40:00 5.3 0.9 7.6 2.6 5.2 1 7.6 2.3 4.1 1.1 6.8 0.4 80 15 79 255 11.7 0 11.9 11.7 09/16/2005 04:50:00 5 1 7.2 2.3 4.9 1 7.2 2.3 3.8 1 6.8 1.5 86 13 97 255 11.6 0 11.7 11.7 09/16/2005 05:00:00 5 1 6.8 2.6 5 1 7.2 2.6 3.9 1 6.5 1.9 86 13 84 255 11.7 0 11.7 11.7 09/16/2005 05:10:00 5 1 7.6 1.9 4.8 1.1 7.2 1.1 3.9 1 6.5 1.9 87 16 87 255 11.7 0 11.9 11.7 09/16/2005 05:20:00 5.4 1 8 2.6 5.3 1.1 8 2.3 4.2 1.2 7.2 1.1 82 13 82 255 11.7 0 11.7 11.7 09/16/2005 05:30:00 5.2 1 8 2.3 5 1 7.2 1.9 4.1 1.1 7.2 1.1 83 13 80 255 11.7 0 11.9 11.7 09/16/2005 05:40:00 5.8 1 8.8 3 5.7 1 8.4 3 4.4 1.1 7.6 1.9 79 15 70 255 11.8 0 11.9 11.7 09/16/2005 05:50:00 5.2 1 8.8 2.6 5.1 1.1 8.4 2.3 4 1 6.8 1.9 80 13 47 255 11.8 0 11.9 11.7 09/16/2005 06:00:00 5.1 0.9 7.6 3 4.9 0.9 8.4 3 3.8 1 6.8 1.5 83 12 71 255 11.7 0 11.7 11.7 09/16/2005 06:10:00 5.3 0.9 7.2 2.6 5.2 0.8 7.2 2.3 4 1 6.5 1.9 80 13 51 255 11.7 0 11.7 11.7 09/16/2005 06:20:00 4.9 1 7.2 1.9 4.8 1.1 7.2 0.4 3.7 0.9 6.1 1.9 85 14 88 255 11.7 0 11.7 11.7 09/16/2005 06:30:00 5.2 0.9 7.2 2.6 5.1 0.9 7.2 2.6 4.1 0.9 6.1 1.5 80 14 59 255 11.7 0 11.9 11.7 09/16/2005 06:40:00 5.9 1.1 8.4 3.4 5.7 1.1 8.4 2.6 4.6 1.2 7.2 1.9 73 13 61 255 11.9 0 11.9 11.7 09/16/2005 06:50:00 5.1 0.9 8 2.6 4.9 0.9 7.6 2.3 3.8 0.9 6.1 1.1 80 15 69 255 11.9 0 11.9 11.9 09/16/2005 07:00:00 5.1 0.9 7.2 3 5 0.9 6.8 2.6 3.8 0.9 6.5 1.9 83 11 93 255 11.7 0 11.9 11.7 09/16/2005 07:10:00 4.6 0.8 7.6 2.6 4.5 0.8 7.2 2.3 3.6 0.8 6.5 1.5 83 11 51 255 11.9 0 11.9 11.7 09/16/2005 07:20:00 4.3 0.8 7.2 2.3 4.3 0.9 7.2 1.9 3.4 0.8 5.7 1.9 87 11 57 255 11.9 0 11.9 11.9 09/16/2005 07:30:00 5 0.8 7.2 2.6 4.8 0.9 7.2 2.3 3.9 1 6.8 1.9 91 11 84 255 11.9 0 11.9 11.9 09/16/2005 07:40:00 5 0.8 6.8 3.4 4.9 0.7 6.8 3.4 4.1 0.8 6.1 1.9 90 11 81 255 12 0 12.2 11.9 09/16/2005 07:50:00 5.2 0.7 7.2 3.4 5.1 0.7 6.8 2.6 4 0.8 5.7 1.5 85 12 81 255 12.1 0 12.2 11.9 09/16/2005 08:00:00 5.1 1 7.2 2.6 4.9 1 7.2 2.6 4 1 6.8 1.5 83 12 87 255 12.2 0 12.2 12.2 09/16/2005 08:10:00 5.4 1 8 3.4 5.3 1 8 2.6 4.2 0.9 7.2 1.9 85 11 73 255 12.3 0 12.5 12.2 09/16/2005 08:20:00 4.9 1.1 7.6 2.3 4.8 1.1 8 1.9 3.9 1 6.5 1.5 87 13 90 255 12.4 0 12.5 12.2 09/16/2005 08:30:00 4.8 0.7 6.8 3 4.7 0.6 6.5 3 4 0.7 6.1 2.3 90 13 91 255 12.7 0 12.7 12.5 09/16/2005 08:40:00 4.3 1 7.2 2.3 4.2 0.9 7.2 2.3 3.4 0.9 6.8 1.5 90 13 93 255 12.8 0 12.7 12.7 09/16/2005 08:50:00 4.3 0.8 6.5 2.3 4.2 0.9 6.5 1.9 3.3 0.8 4.9 1.1 94 14 100 255 12.8 0 12.7 12.7 09/16/2005 09:00:00 4.7 0.8 6.8 2.3 4.6 0.8 6.8 2.6 3.6 1 5.7 1.1 90 15 102 255 12.9 0 13 12.7 09/16/2005 09:10:00 4.2 1 6.8 1.9 4.1 1 7.2 1.5 3.4 1.1 6.5 0.4 88 15 68 255 13.1 0 13.3 13 09/16/2005 09:20:00 3.9 0.8 6.1 1.9 3.7 0.9 6.1 1.5 3.2 0.8 5.3 1.1 94 15 98 255 13.2 0 13.3 13 09/16/2005 09:30:00 3.3 0.9 5.7 0.7 3.1 1 5.7 0.4 2.5 1 4.9 0.4 82 17 80 255 13.3 0 13.3 13 09/16/2005 09:40:00 3.6 1 6.1 0.7 3.4 1 6.1 0.4 2.6 1 5.3 0.7 81 17 66 255 13.3 0 13.3 13.3 09/16/2005 09:50:00 3.8 0.7 5.7 1.9 3.6 0.7 5.7 1.9 3.1 0.9 5.3 1.1 93 13 94 255 13.3 0 13.3 13.3 09/16/2005 10:00:00 3.8 0.9 6.5 1.9 3.7 1 6.1 1.1 3 0.9 5.7 0.7 90 15 73 255 13.3 0 13.3 13.3 09/16/2005 10:10:00 4.6 0.9 8 2.3 4.5 1 8 1.9 3.6 0.8 6.5 1.9 81 17 70 255 13.3 0 13.3 13.3 09/16/2005 10:20:00 4.1 0.9 6.5 1.9 3.9 1 6.5 1.5 3.2 1 6.1 0.7 80 16 62 255 13.3 0 13.5 13.3 09/16/2005 10:30:00 4.1 1 6.8 1.9 3.9 1 6.5 1.5 3.3 1 6.1 1.1 85 17 85 255 13.3 0 13.5 13.3 09/16/2005 10:40:00 4.1 1 7.2 1.9 3.9 1.1 6.8 1.5 3.3 1.1 6.5 0.7 77 17 56 255 13.3 0 13.3 13.3 09/16/2005 10:50:00 3.6 1 6.5 1.5 3.5 1.1 6.5 0.7 2.7 1 5.3 0.4 70 17 61 255 13.3 0 13.3 13.3 09/16/2005 11:00:00 4.4 1.1 7.2 1.9 4.3 1.1 6.8 1.5 3.6 1.2 6.8 0.7 66 16 67 255 13.3 0 13.3 13.3 09/16/2005 11:10:00 4.5 1 7.6 1.9 4.4 1 7.2 2.3 3.6 1.1 6.8 0.7 64 17 81 255 13.3 0 13.5 13.3 09/16/2005 11:20:00 4 0.8 6.1 1.9 3.8 0.8 6.1 1.1 3.1 0.9 5.7 1.1 70 19 44 255 13.5 0 13.5 13.3 09/16/2005 11:30:00 4.6 0.9 7.2 2.6 4.5 0.9 7.2 2.3 3.6 0.9 5.7 1.1 66 15 67 255 13.4 0 13.5 13.3 09/16/2005 11:40:00 4.3 1 6.8 1.1 4.1 1 6.5 1.5 3.3 0.9 6.1 1.1 63 17 107 255 13.5 0 13.5 13.3 09/16/2005 11:50:00 4.6 1 6.8 2.3 4.5 1 6.5 2.3 3.8 0.9 5.7 1.9 65 15 62 255 13.7 0 13.8 13.5 09/16/2005 12:00:00 4 0.9 6.8 1.5 3.9 1 6.8 0.7 3.2 0.9 6.1 0.7 67 17 69 255 13.7 0 13.8 13.5 09/16/2005 12:10:00 4.2 1.1 7.2 0.7 4.1 1.2 6.8 1.1 3.3 1.2 6.5 0.7 62 17 83 255 13.5 0 13.8 13.3 09/16/2005 12:20:00 4.4 0.9 6.8 2.3 4.1 1 6.8 1.5 3.5 0.9 5.7 1.1 47 12 32 255 13.3 0 13.5 13.3 09/16/2005 12:30:00 4.2 0.9 6.8 1.9 4.1 0.9 6.8 1.5 3.3 1 6.1 1.1 59 17 53 255 13.3 0 13.5 13.3 09/16/2005 12:40:00 4.2 0.8 6.8 1.9 4.1 0.9 6.5 1.1 3.3 1 6.5 1.1 59 15 55 255 13.3 0 13.5 13.3 09/16/2005 12:50:00 4.4 1 6.5 2.3 4.3 1 6.5 1.9 3.4 0.9 6.1 1.5 65 16 43 255 13.3 0 13.5 13.3 09/16/2005 13:00:00 5 1 7.2 2.3 5 1 7.6 1.5 3.9 1 6.8 1.5 57 13 62 255 13.3 0 13.3 13.3 09/16/2005 13:10:00 4.9 1 7.2 2.6 4.8 1.2 7.2 1.9 3.8 1.2 6.8 1.1 60 15 70 255 13.3 0 13.3 13.3 09/16/2005 13:20:00 5.4 0.9 7.2 3 5.3 1 7.2 2.6 4.4 0.9 6.8 1.9 47 13 61 255 13.3 0 13.5 13.3 09/16/2005 13:30:00 5.2 1 8 2.6 5.1 1 8 2.3 4.1 1 6.8 1.9 47 15 42 255 13.3 0 13.5 13.3 09/16/2005 13:40:00 4.7 1 8 2.3 4.6 1.1 8 1.9 3.8 1.1 7.2 1.9 54 14 55 255 13.4 0 13.5 13.3 09/16/2005 13:50:00 5 1 8.4 3 4.9 1.1 7.6 2.3 3.9 1 6.1 1.9 56 14 40 255 13.4 0 13.5 13.3 09/16/2005 14:00:00 5 1.1 8 1.9 4.9 1.2 7.6 1.9 4 1.1 6.8 1.1 44 17 36 255 13.5 0 13.5 13.3 09/16/2005 14:10:00 5.6 1.4 9.1 2.3 5.5 1.5 9.1 1.9 4.5 1.3 7.6 0.7 48 17 46 255 13.5 0 13.5 13.3 09/16/2005 14:20:00 6 1.1 8.8 3 5.9 1.2 8.8 3 4.9 1.2 7.2 2.3 43 16 31 255 13.3 0 13.5 13.3 09/16/2005 14:30:00 4.6 1 6.8 1.5 4.5 1 6.8 1.9 3.7 1 6.1 0.4 49 18 58 255 13.3 0 13.3 13 09/16/2005 14:40:00 4.8 1 7.6 3 4.7 1 7.6 2.6 3.7 0.9 6.5 1.5 49 16 37 255 13.3 0 13.3 13 09/16/2005 14:50:00 4.2 0.8 6.8 1.9 4.1 0.9 6.5 1.5 3.2 0.8 5.7 1.5 56 17 73 255 13.3 0 13.3 13.3 09/16/2005 15:00:00 4 1.1 6.5 1.5 3.8 1.1 6.8 1.5 3.3 1 6.1 1.1 68 16 76 255 13.3 0 13.3 13.3 09/16/2005 15:10:00 3.6 0.9 6.5 1.9 3.4 1 6.5 1.1 2.9 0.9 6.5 0.7 64 15 86 255 13.3 0 13.3 13.3 09/16/2005 15:20:00 4 0.8 6.5 1.9 3.9 0.9 6.1 1.1 3.4 0.8 5.7 1.9 67 13 55 255 13.2 0 13.3 13 09/16/2005 15:30:00 2.8 0.7 5.3 1.1 2.6 0.8 5.3 0.7 2.3 0.8 4.6 1.1 81 14 81 255 13.1 0 13.3 13 09/16/2005 15:40:00 3 0.9 4.9 1.1 2.7 1 4.9 0.4 2.3 0.9 4.9 0.4 75 19 55 255 12.9 0 13 12.7 09/16/2005 15:50:00 4 1.2 7.2 1.5 3.8 1.3 7.2 1.1 3.3 1 6.5 1.1 59 16 72 255 13.1 0 13.3 12.7 09/16/2005 16:00:00 5.8 1.2 9.5 2.6 5.7 1.3 9.1 2.6 4.8 1.3 8.8 1.1 46 18 31 255 13.1 0 13.3 13 09/16/2005 16:10:00 6.4 1 9.1 3.8 6.3 1.1 10.3 3.8 5.3 1 7.6 3 36 12 52 255 13.1 0 13.3 13 09/16/2005 16:20:00 6.2 1.3 9.9 3.4 6.1 1.4 10.3 3 5.1 1.2 9.5 2.3 37 16 39 255 13 0 13.3 13 09/16/2005 16:30:00 7 1.4 10.3 3.8 6.9 1.3 10.3 3.8 5.8 1.4 9.5 2.3 28 13 20 255 12.8 0 13 12.7 09/16/2005 16:40:00 7.6 1.3 10.7 3.4 7.5 1.3 11.5 3 6.3 1.3 9.5 2.3 38 15 39 255 12.8 0 12.7 12.7 09/16/2005 16:50:00 6.3 1.3 10.7 3.4 6.3 1.3 10.7 3.4 5.2 1.3 9.5 2.3 46 13 46 255 12.7 0 12.7 12.7 09/16/2005 17:00:00 7.6 1.8 12.6 4.2 7.5 1.8 13.3 3.8 6.4 1.9 11.5 2.6 42 14 31 255 12.5 0 12.7 12.2 09/16/2005 17:10:00 7.3 1.3 10.7 3.8 7.2 1.4 10.7 4.2 5.9 1.4 9.1 2.3 41 14 45 255 12 0.1 12.2 11.7 09/16/2005 17:20:00 6.7 1.5 10.7 3.4 6.7 1.5 10.7 3.8 5.4 1.5 9.5 2.3 47 16 59 255 11.7 0 11.9 11.7 09/16/2005 17:30:00 6.1 1.1 9.5 3.4 6.1 1.1 9.1 3 5.1 1.2 8.8 1.9 44 14 57 255 11.7 0 11.9 11.7 09/16/2005 17:40:00 4.9 1.2 7.6 2.3 4.9 1.2 7.6 2.3 4 1.1 6.8 1.1 50 17 66 255 11.9 0 11.9 11.7 09/16/2005 17:50:00 5 1.2 8.4 2.6 5 1.2 8 2.3 4.1 1.1 7.2 1.9 53 14 53 255 12 0 12.2 11.9 09/16/2005 18:00:00 5.6 1.2 8 2.3 5.6 1.3 8.8 2.3 4.4 1.3 8 1.9 55 17 52 255 12.1 0 12.2 11.9 09/16/2005 18:10:00 5.3 1.2 8 2.6 5.3 1.2 8 2.3 4.3 1.2 8.4 1.9 58 16 31 255 12.1 0 12.2 11.9 09/16/2005 18:20:00 4.4 1 7.6 1.9 4.4 1.1 7.6 1.9 3.7 1.1 7.2 0.4 67 19 52 255 11.9 0 12.2 11.7 09/16/2005 18:30:00 3.9 1 6.5 1.9 3.8 1 6.5 1.9 3.1 1 6.1 0.7 67 15 50 255 11.7 0 11.7 11.7 09/16/2005 18:40:00 3.6 0.8 6.1 1.1 3.5 0.9 6.5 1.1 2.9 0.8 4.9 1.1 61 16 67 255 11.5 0 11.7 11.4 09/16/2005 18:50:00 3.3 0.9 5.3 1.1 3.2 0.9 5.7 1.1 2.4 0.8 4.2 0.4 53 15 59 255 11.2 0 11.4 11.1 09/16/2005 19:00:00 2.7 0.6 4.6 1.5 2.7 0.6 4.2 1.1 2.2 0.7 4.2 0.4 56 12 52 255 10.9 0 11.1 10.9 09/16/2005 19:10:00 3.5 0.6 4.9 1.9 3.5 0.6 4.9 1.9 3 0.5 4.6 1.5 35 8 42 255 10.9 0 11.1 10.9 09/16/2005 19:20:00 5 0.7 6.8 3 4.9 0.7 6.8 3 4.1 0.7 5.7 2.3 26 10 32 255 10.9 0 11.1 10.9 09/16/2005 19:30:00 5.8 0.8 8.4 3.8 5.8 0.8 8.4 3.8 5 0.9 7.2 3 31 10 22 255 10.9 0 11.1 10.9 09/16/2005 19:40:00 5.5 0.7 7.2 3.8 5.5 0.7 7.2 3.8 4.2 1 6.5 1.5 18 9 14 255 10.8 0.1 11.1 10.6 09/16/2005 19:50:00 3.8 0.9 5.7 1.9 3.8 0.9 6.1 1.9 2.6 0.8 4.9 1.1 14 9 17 255 10.6 0 10.9 10.6 09/16/2005 20:00:00 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.6 3 0.6 4.6 1.5 20 7 22 255 10.5 0 10.6 10.3 09/16/2005 20:10:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.5 2 0.6 3.4 0.7 16 6 17 255 10.3 0 10.6 10.3 09/16/2005 20:20:00 2.4 0.6 3.8 0.4 2.2 0.7 3.8 0.4 1.7 0.7 3 0.4 39 13 32 255 10.2 0 10.3 10.3 09/16/2005 20:30:00 1.2 0.8 3 0.4 1 0.8 3 0.4 0.8 0.5 2.3 0.4 29 33 66 255 10.2 0 10.3 10.1 09/16/2005 20:40:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 18 33 62 255 10 0 10.1 9.8 09/16/2005 20:50:00 1.8 0.7 3 0.4 1.5 0.7 3 0.4 1 0.5 2.3 0.4 62 21 29 255 9.9 0 10.1 9.8 09/16/2005 21:00:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 83 21 95 255 9.8 0 10.1 9.6 09/16/2005 21:10:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 47 9 19 255 9.6 0.1 9.8 9.6 09/16/2005 21:20:00 0.7 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 64 0 64 255 9.5 0 9.6 9.3 09/16/2005 21:30:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 59 20 78 255 9.3 0 9.3 9.3 09/16/2005 21:40:00 2.8 0.9 4.9 1.1 2.5 1 4.6 0.4 1.8 1 3.8 0.4 47 11 43 255 9.1 0 9.3 9 09/16/2005 21:50:00 3.5 0.4 4.6 2.6 3.3 0.4 4.6 2.3 2.7 0.5 3.8 1.1 38 7 43 255 9.4 0 9.6 9.3 09/16/2005 22:00:00 2.6 0.5 3.8 0.7 2.3 0.6 3.8 0.4 1.6 0.7 3.4 0.4 45 11 27 255 9.4 0 9.6 9.3 09/16/2005 22:10:00 1.9 0.5 3 0.7 1.5 0.5 2.6 0.4 1 0.4 1.9 0.4 4 17 8 255 9.2 0 9.3 9 09/16/2005 22:20:00 2.3 0.4 3 1.1 2 0.5 3 0.4 1.2 0.5 2.6 0.4 37 17 8 255 9 0 9.3 9 09/16/2005 22:30:00 1 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 63 7 53 255 8.9 0 9 9 09/16/2005 22:40:00 0.8 0.4 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.9 0.4 58 16 32 255 8.9 0 9 8.8 09/16/2005 22:50:00 1.6 0.4 2.6 0.7 1.2 0.5 2.6 0.4 0.8 0.5 2.6 0.4 5 13 27 255 8.9 0 9 8.8 09/16/2005 23:00:00 0.8 0.5 2.6 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 77 28 30 255 8.7 0 9 8.8 09/16/2005 23:10:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 62 21 83 255 8.8 0 9 8.8 09/16/2005 23:20:00 1.6 0.4 2.6 0.7 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 67 8 74 255 8.8 0 9 8.8 09/16/2005 23:30:00 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 44 6 57 255 8.8 0 9 8.8 09/16/2005 23:40:00 1.3 0.3 1.9 0.7 0.8 0.3 1.9 0.4 0.4 0.2 1.5 0.4 44 5 43 255 8.7 0 8.8 8.8 09/16/2005 23:50:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 45 0 45 255 8.7 0 8.8 8.8 09/17/2005 00:00:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 0 45 255 8.7 0 9 8.8 09/17/2005 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 0 45 255 8.7 0 8.8 8.8 09/17/2005 00:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 0 45 255 8.7 0 8.8 8.8 09/17/2005 00:30:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 53 6 45 255 8.7 0 8.8 8.5 09/17/2005 00:40:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 76 4 60 255 8.6 0 8.8 8.5 09/17/2005 00:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 77 0 77 255 8.5 0 8.8 8.5 09/17/2005 01:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 0 77 255 8.5 0 8.5 8.5 09/17/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 0 255 255 8.4 0 8.5 8.3 09/17/2005 01:20:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 77 0 77 255 8.3 0 8.5 8.3 09/17/2005 01:30:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 84 11 77 255 8.2 0 8.5 8 09/17/2005 01:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 0 101 255 8 0 8.3 8 09/17/2005 01:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 101 0 101 255 8.1 0 8.3 8 09/17/2005 02:00:00 1 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.3 1.5 0.4 80 17 101 255 8.3 0 8.5 8.3 09/17/2005 02:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 62 255 8.4 0 8.5 8.5 09/17/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 62 0 255 255 8.4 0 8.5 8.5 09/17/2005 02:30:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.9 0.5 1.9 0.4 131 26 141 255 8.4 0 8.5 8.5 09/17/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 0 255 255 8.3 0 8.5 8.3 09/17/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 0 255 255 8.3 0 8.3 8.3 09/17/2005 03:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 0 141 255 8.1 0 8.3 8.3 09/17/2005 03:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 0 141 255 8.1 0 8.3 8 09/17/2005 03:20:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 0 141 255 8.2 0 8.5 8.3 09/17/2005 03:30:00 1.2 0.2 1.9 0.7 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 86 24 70 255 8.3 0 8.5 8.3 09/17/2005 03:40:00 1.3 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 79 7 70 255 8.4 0 8.5 8.3 09/17/2005 03:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 0 86 255 8.4 0 8.5 8.5 09/17/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 85 0 255 255 8.3 0 8.5 8.3 09/17/2005 04:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 135 12 139 255 8 0 8.3 7.8 09/17/2005 04:20:00 1.7 0.3 2.3 1.1 1.2 0.4 1.9 0.4 0.8 0.5 1.9 0.4 103 12 109 255 7.7 0.1 8 7.5 09/17/2005 04:30:00 1.2 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 98 7 111 255 7.3 0 7.5 7.3 09/17/2005 04:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 0 94 255 7.1 0 7.3 7 09/17/2005 04:50:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 100 19 94 255 7.1 0 7.3 7 09/17/2005 05:00:00 1.2 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 153 6 158 255 7 0 7.3 7 09/17/2005 05:10:00 1.6 0.2 1.9 1.1 1.1 0.2 1.5 0.4 0.9 0.4 1.9 0.4 144 4 142 255 7.1 0 7.3 7 09/17/2005 05:20:00 1.7 0.3 2.3 1.1 1.1 0.3 1.9 0.4 1.2 0.4 2.3 0.4 155 4 158 255 7.4 0.1 7.5 7.3 09/17/2005 05:30:00 1.2 0.3 1.9 0.4 0.6 0.2 1.1 0.4 0.6 0.3 1.5 0.4 146 4 141 255 7.6 0 7.8 7.5 09/17/2005 05:40:00 1.4 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 145 6 140 255 7.6 0 7.8 7.5 09/17/2005 05:50:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 157 0 154 255 7.9 0 8 7.8 09/17/2005 06:00:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 169 8 158 255 8 0 8.3 8 09/17/2005 06:10:00 1 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 174 0 174 255 8.2 0 8.3 8 09/17/2005 06:20:00 1.3 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.5 1.9 0.4 154 5 153 255 8.3 0 8.5 8.3 09/17/2005 06:30:00 1.3 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 157 7 165 255 8.5 0 8.5 8.5 09/17/2005 06:40:00 1.3 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 146 14 135 255 8.5 0 8.8 8.5 09/17/2005 06:50:00 1.1 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 149 8 156 255 8.7 0 8.8 8.5 09/17/2005 07:00:00 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 132 13 148 255 8.7 0 8.8 8.5 09/17/2005 07:10:00 0.4 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 122 3 121 255 8.7 0 8.8 8.5 09/17/2005 07:20:00 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 122 16 134 255 8.6 0 8.8 8.5 09/17/2005 07:30:00 1.1 0.5 2.3 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 103 4 94 255 8.5 0 8.8 8.5 09/17/2005 07:40:00 1 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 102 0 102 255 8.3 0 8.5 8.3 09/17/2005 07:50:00 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 111 14 102 255 8.1 0 8.5 8 09/17/2005 08:00:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 128 24 113 255 8 0 8.3 8 09/17/2005 08:10:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 108 11 90 255 8.1 0 8.3 8 09/17/2005 08:20:00 0.9 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 100 8 101 255 8.3 0 8.5 8.3 09/17/2005 08:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 111 2 115 255 8.4 0 8.5 8.5 09/17/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 8.6 0 8.8 8.5 09/17/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 8.8 0 9 8.8 09/17/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 8.9 0 9 8.8 09/17/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 9.2 0 9.3 9 09/17/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 9.5 0 9.6 9.3 09/17/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 111 0 255 255 9.6 0 9.8 9.6 09/17/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 9.9 0 10.1 9.6 09/17/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 10.1 0 10.3 10.1 09/17/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 29 255 255 10.5 0 10.6 10.3 09/17/2005 10:10:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 322 13 318 255 10.6 0 10.6 10.6 09/17/2005 10:20:00 1.3 0.6 2.6 0.4 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 309 4 308 255 10.6 0 10.9 10.6 09/17/2005 10:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 296 17 319 255 10.7 0 10.9 10.6 09/17/2005 10:40:00 0.6 0.4 2.3 0.4 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 267 6 293 255 10.8 0 11.1 10.6 09/17/2005 10:50:00 1.2 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 251 22 243 255 11.2 0.1 11.7 10.9 09/17/2005 11:00:00 1.2 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.8 0.4 2.3 0.4 246 39 270 255 12.1 0.1 12.2 11.7 09/17/2005 11:10:00 0.8 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.7 0.4 2.6 0.4 254 26 261 255 12.1 0 12.2 11.9 09/17/2005 11:20:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 222 38 245 255 12 0 12.2 11.9 09/17/2005 11:30:00 0.8 0.6 3 0.4 0.7 0.6 3 0.4 0.6 0.4 1.9 0.4 262 43 280 255 12.3 0 12.2 12.2 09/17/2005 11:40:00 1.9 0.5 3 0.4 1.7 0.5 3 0.4 1.4 0.6 2.6 0.4 286 29 276 255 12.3 0 12.2 12.2 09/17/2005 11:50:00 1.8 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.7 3 0.4 270 47 294 255 12.3 0 12.5 12.2 09/17/2005 12:00:00 2.1 0.8 4.6 0.7 1.7 0.8 4.6 0.4 1.3 0.7 3.8 0.4 325 28 351 255 12.1 0 12.2 11.9 09/17/2005 12:10:00 2.4 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.7 0.7 3.4 0.4 281 21 300 255 11.8 0 12.2 11.7 09/17/2005 12:20:00 1.9 0.7 3.8 0.4 1.6 0.8 3.4 0.4 1.3 0.7 3.4 0.4 264 26 240 255 12.1 0.2 12.7 11.7 09/17/2005 12:30:00 2.1 0.6 3.8 0.7 1.8 0.7 3.8 0.4 1.5 0.8 3.8 0.4 235 24 256 255 12.7 0 12.7 12.5 09/17/2005 12:40:00 0.9 0.7 3 0.4 0.8 0.6 2.6 0.4 0.6 0.4 2.3 0.4 222 20 244 255 12.7 0 13 12.5 09/17/2005 12:50:00 0.9 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.7 0.5 2.3 0.4 197 22 208 255 12.8 0 13 12.7 09/17/2005 13:00:00 1.1 0.5 2.6 0.4 1 0.5 2.3 0.4 0.9 0.6 2.6 0.4 193 12 192 255 13.1 0 13.3 12.7 09/17/2005 13:10:00 0.6 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 134 49 136 255 13.5 0 13.5 13.3 09/17/2005 13:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 149 76 354 255 13.5 0 13.8 13.3 09/17/2005 13:30:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.2 1.9 0.4 264 45 287 255 14 0.1 14.6 13.8 09/17/2005 13:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 272 76 19 255 14.1 0.1 14.6 13.8 09/17/2005 13:50:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 1 0.5 2.6 0.4 153 45 161 255 14.1 0.2 14.9 13.8 09/17/2005 14:00:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 47 79 8 255 14.3 0.2 15.2 13.8 09/17/2005 14:10:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 26 69 27 255 15.1 0.2 15.7 14.6 09/17/2005 14:20:00 1.6 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.2 0.8 3.4 0.4 357 36 12 255 15.1 0 15.7 14.9 09/17/2005 14:30:00 0.8 0.6 2.6 0.4 0.7 0.6 3 0.4 0.6 0.4 2.3 0.4 358 69 20 255 15.4 0 16 15.2 09/17/2005 14:40:00 1.7 1 4.9 0.4 1.5 0.8 4.2 0.4 1.3 0.9 3.8 0.4 337 22 327 255 15.5 0 16.3 15.5 09/17/2005 14:50:00 1.4 0.8 3 0.4 1.1 0.7 3 0.4 0.9 0.5 2.3 0.4 314 72 316 255 15.4 0.2 16 15.2 09/17/2005 15:00:00 1.7 1 4.2 0.4 1.4 1 3.8 0.4 1.1 0.8 3.8 0.4 299 82 7 255 14.8 0 15.5 14.6 09/17/2005 15:10:00 2 1 4.2 0.4 2 1 4.2 0.4 1.7 1 4.2 0.4 7 23 15 255 15 0 15.5 14.9 09/17/2005 15:20:00 3 0.8 4.9 1.1 2.9 0.8 4.6 1.1 2.7 0.8 4.9 1.1 7 24 330 255 15 0 15.5 14.9 09/17/2005 15:30:00 1.7 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.4 0.6 3 0.4 12 24 348 255 15.3 0 15.7 15.2 09/17/2005 15:40:00 1.8 1 4.6 0.4 1.6 1 4.6 0.4 1.5 1 4.2 0.4 24 35 22 255 15.6 0 16.3 15.5 09/17/2005 15:50:00 1.3 1.1 5.3 0.4 1.2 1.1 4.9 0.4 1 0.9 4.9 0.4 345 49 32 255 15.9 0 16.6 16 09/17/2005 16:00:00 2.1 1 4.9 0.4 2 1 4.9 0.4 1.6 1 4.6 0.4 350 32 3 255 16.2 0.1 16.8 16 09/17/2005 16:10:00 2.1 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.5 0.8 3.4 0.4 338 27 356 255 15.9 0.2 16.8 15.7 09/17/2005 16:20:00 2.2 0.6 3.4 0.4 2 0.6 3.4 0.4 1.4 0.6 3 0.4 335 32 10 255 15.8 0 16.3 15.7 09/17/2005 16:30:00 2.9 1.1 4.9 0.4 2.8 1.1 4.9 0.4 2.1 1 4.2 0.4 353 22 343 255 15.4 0 16 15.5 09/17/2005 16:40:00 1.7 0.8 3.4 0.4 1.4 0.7 3 0.4 1.1 0.7 3 0.4 342 21 338 255 15.2 0.1 15.7 15.2 09/17/2005 16:50:00 1 0.5 2.3 0.4 0.9 0.4 2.6 0.4 0.7 0.4 1.9 0.4 359 19 7 255 15.2 0 15.5 15.2 09/17/2005 17:00:00 2.3 0.6 3.8 0.7 2.3 0.5 3.4 1.1 1.8 0.6 3.4 0.4 41 27 58 255 15.2 0 15.7 15.2 09/17/2005 17:10:00 2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.3 0.7 3.4 0.4 336 23 305 255 15.2 0 15.5 15.2 09/17/2005 17:20:00 1.8 1 3.8 0.4 1.7 0.9 3.8 0.4 1.3 0.8 3.4 0.4 344 28 11 255 15 0 15.5 14.9 09/17/2005 17:30:00 2.7 0.7 4.2 1.1 2.7 0.7 4.2 0.7 2.2 0.7 4.2 0.4 49 19 51 255 14.8 0 15.2 14.6 09/17/2005 17:40:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 2.8 0.6 4.2 1.1 39 10 34 255 14.6 0 14.9 14.6 09/17/2005 17:50:00 3.2 0.6 4.6 1.5 3.2 0.6 4.6 1.9 2.7 0.7 4.6 0.7 31 13 24 255 14.3 0 14.9 14.1 09/17/2005 18:00:00 2.5 0.6 4.2 1.1 2.5 0.6 4.2 1.1 1.9 0.6 3 0.4 33 13 15 255 13.9 0 14.6 13.5 09/17/2005 18:10:00 2.3 0.5 3.4 1.1 2.4 0.5 3.8 1.5 1.6 0.6 3 0.4 16 12 8 255 13.5 0 14.1 13.3 09/17/2005 18:20:00 2 0.4 2.6 1.1 2 0.3 2.6 1.1 1.4 0.5 2.6 0.4 33 14 16 255 13.1 0.1 13.3 13 09/17/2005 18:30:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 1.7 0.6 3 0.4 38 11 37 255 12.9 0 13 12.7 09/17/2005 18:40:00 1.7 0.4 2.6 0.7 1.7 0.4 2.3 0.4 0.8 0.5 1.9 0.4 14 13 17 255 12.5 0.1 13 12.2 09/17/2005 18:50:00 1.6 0.3 2.3 0.4 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 357 10 355 255 11.9 0.1 12.2 11.7 09/17/2005 19:00:00 1.7 0.6 2.6 0.4 1.6 0.6 2.6 0.4 0.4 0.2 1.5 0.4 14 5 0 255 11.4 0.1 11.7 11.1 09/17/2005 19:10:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 30 22 47 255 10.9 0.1 11.1 10.6 09/17/2005 19:20:00 1.3 0.3 1.9 0.7 1.3 0.3 1.9 0.7 0.7 0.3 1.5 0.4 51 8 47 255 10.6 0 10.9 10.6 09/17/2005 19:30:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.5 0.2 1.5 0.4 56 11 58 255 10.2 0 10.6 10.1 09/17/2005 19:40:00 1.4 0.6 2.6 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.3 0.4 43 13 47 255 9.8 0.1 10.1 9.6 09/17/2005 19:50:00 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 0.7 0.4 1.9 0.4 29 14 39 255 9.6 0 9.6 9.6 09/17/2005 20:00:00 2 0.4 3 1.1 1.9 0.4 3 0.7 1 0.5 2.3 0.4 74 17 43 255 9.4 0 9.6 9.3 09/17/2005 20:10:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 0.8 0.4 1.5 0.4 89 13 111 255 9 0 9.3 8.8 09/17/2005 20:20:00 1.2 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 61 11 70 255 8.7 0 9 8.5 09/17/2005 20:30:00 1.7 0.3 2.3 1.1 1.4 0.3 1.9 0.7 0.5 0.2 1.5 0.4 99 8 91 255 8.6 0 8.8 8.5 09/17/2005 20:40:00 1.3 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 90 15 106 255 8.7 0 8.8 8.5 09/17/2005 20:50:00 1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 36 17 25 255 8.9 0 9 8.8 09/17/2005 21:00:00 1.2 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 352 16 20 255 8.9 0 9 8.8 09/17/2005 21:10:00 1.6 0.9 3 0.4 1.4 0.9 3 0.4 1.6 1 3.4 0.4 93 64 140 255 8.7 0 9 8.5 09/17/2005 21:20:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.1 0.5 2.6 0.4 119 8 139 255 8.9 0 9 8.8 09/17/2005 21:30:00 2.1 0.6 3.4 0.7 2 0.6 3.4 0.7 1.2 0.5 2.6 0.4 119 10 132 255 8.7 0 8.8 8.5 09/17/2005 21:40:00 2.6 0.7 3.8 0.7 2.5 0.7 4.2 0.7 1.9 0.6 3.4 0.4 136 7 122 255 8.9 0 9 8.8 09/17/2005 21:50:00 2 0.7 3.4 0.4 1.9 0.6 3.4 0.4 1 0.6 3 0.4 108 12 115 255 9.2 0 9.3 9 09/17/2005 22:00:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0 0.7 0.4 106 7 121 255 9.2 0 9.3 9 09/17/2005 22:10:00 2.1 0.4 3 1.1 1.9 0.4 2.6 1.1 0.8 0.4 1.9 0.4 104 7 100 255 9.1 0 9.3 9 09/17/2005 22:20:00 1.9 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1 0.4 1.9 0.4 106 8 97 255 9 0 9.3 9 09/17/2005 22:30:00 1.2 0.5 2.3 0.4 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 136 9 124 255 8.9 0 9 8.8 09/17/2005 22:40:00 1.9 0.4 3 1.1 1.7 0.4 2.6 0.7 1 0.4 2.3 0.4 121 10 116 255 8.9 0 9 8.8 09/17/2005 22:50:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 123 11 100 255 8.9 0 9 8.8 09/17/2005 23:00:00 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 110 9 97 255 8.9 0 9 8.8 09/17/2005 23:10:00 1.5 0.4 3 0.7 1.1 0.5 2.6 0.4 0.5 0.3 1.5 0.4 114 9 130 255 8.9 0 9 8.8 09/17/2005 23:20:00 2.4 0.7 4.2 1.1 2.2 0.7 3.8 0.4 1.5 0.7 3.4 0.4 126 16 115 255 9 0 9 8.8 09/17/2005 23:30:00 2.4 0.6 4.6 1.5 2.2 0.6 3.8 1.1 1.3 0.7 3.8 0.4 132 12 133 255 9.1 0 9.3 9 09/17/2005 23:40:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.1 1.1 0.4 103 7 104 255 8.8 0 9 8.5 09/17/2005 23:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 38 15 34 255 8.4 0 8.8 8.3 09/18/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 255 255 8.1 0 8.5 8 09/18/2005 00:10:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 42 10 41 255 8 0 8.3 8 09/18/2005 00:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 42 0 41 255 8 0 8.3 8 09/18/2005 00:30:00 0.9 0.8 3 0.4 0.8 0.7 2.6 0.4 0.8 0.7 2.3 0.4 96 64 167 255 8 0 8.3 8 09/18/2005 00:40:00 1.9 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 163 10 152 255 8.1 0 8.3 8 09/18/2005 00:50:00 2.4 0.5 4.2 1.5 2.2 0.5 3.8 1.1 1.5 0.5 3 0.4 139 13 145 255 8.3 0 8.5 8.3 09/18/2005 01:00:00 2 0.5 3 0.7 1.7 0.5 2.6 0.4 1.3 0.5 2.6 0.4 131 10 138 255 8.3 0 8.5 8.3 09/18/2005 01:10:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 154 14 161 255 8.2 0 8.3 8.3 09/18/2005 01:20:00 1.7 0.4 2.3 0.4 1.3 0.4 1.9 0.4 0.9 0.5 1.9 0.4 164 4 159 255 8.1 0 8.3 8 09/18/2005 01:30:00 1.6 0.4 2.3 0.4 1.2 0.4 1.9 0.4 0.9 0.4 1.9 0.4 155 8 160 255 7.9 0 8 7.8 09/18/2005 01:40:00 1.8 0.4 2.6 0.4 1.5 0.4 2.3 0.4 0.8 0.5 1.9 0.4 135 19 124 255 7.8 0 8 7.8 09/18/2005 01:50:00 2 0.4 3 0.7 1.7 0.4 3 0.4 0.6 0.4 1.5 0.4 106 13 99 255 7.7 0 7.8 7.5 09/18/2005 02:00:00 0.7 0.6 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.1 0.4 103 19 94 255 7.6 0 7.8 7.5 09/18/2005 02:10:00 1.6 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.6 0.5 2.6 0.4 283 56 291 255 7.8 0 7.8 7.8 09/18/2005 02:20:00 1 0.8 3.8 0.4 0.9 0.7 3.4 0.4 0.6 0.4 2.6 0.4 318 22 318 255 7.8 0 7.8 7.5 09/18/2005 02:30:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 302 12 290 255 7.6 0 7.8 7.5 09/18/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 0 255 255 7.6 0 7.8 7.5 09/18/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 0 255 255 7.3 0 7.5 7.3 09/18/2005 03:00:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 280 26 260 255 7.3 0 7.5 7.3 09/18/2005 03:10:00 1.3 0.4 2.3 0.4 1.2 0.3 1.9 0.4 1.4 0.4 2.3 0.4 208 22 200 255 7.1 0 7.3 7 09/18/2005 03:20:00 1.9 0.6 3 0.7 1.9 0.4 3 0.7 1.5 0.4 2.3 0.4 172 9 164 255 7.1 0 7.3 7.3 09/18/2005 03:30:00 2.3 0.4 3.4 1.5 2 0.4 3 0.7 1.3 0.5 2.3 0.4 154 8 167 255 7.2 0 7.3 7.3 09/18/2005 03:40:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 145 5 153 255 7.1 0 7.3 7 09/18/2005 03:50:00 1.3 0.7 2.3 0.4 1.1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 67 56 30 255 6.8 0 7 6.7 09/18/2005 04:00:00 1.7 0.4 2.3 0.4 1.5 0.5 2.3 0.4 1 0.5 1.9 0.4 30 10 20 255 6.7 0 6.7 6.7 09/18/2005 04:10:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 0.9 0.4 1.9 0.4 67 11 53 255 6.9 0 7 6.7 09/18/2005 04:20:00 1 0.6 2.6 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 59 6 53 255 7 0 7.3 7 09/18/2005 04:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 84 23 80 255 7.1 0 7.3 7 09/18/2005 04:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 81 0 81 255 7.1 0 7.3 7 09/18/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 255 255 6.9 0 7 6.7 09/18/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 97 32 255 255 6.6 0 6.7 6.2 09/18/2005 05:10:00 1.1 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 205 9 186 255 6.2 0 6.5 6 09/18/2005 05:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 207 10 188 255 5.9 0 6.2 5.7 09/18/2005 05:30:00 0.9 0.3 1.9 0.4 0.8 0.3 1.5 0.4 1.2 0.4 1.5 0.4 184 8 169 255 5.7 0 6 5.7 09/18/2005 05:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 176 8 183 255 5.4 0.1 5.7 5.2 09/18/2005 05:50:00 1.6 0.4 2.3 0.7 1.3 0.4 2.3 0.4 0.7 0.4 1.5 0.4 162 0 162 255 5.1 0 5.5 5 09/18/2005 06:00:00 2.2 0.4 3 1.1 2 0.3 2.6 1.1 1.3 0.4 2.3 0.4 162 7 158 255 5.1 0 5 5 09/18/2005 06:10:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.9 0.4 2.3 0.4 145 11 158 255 5.1 0 5.2 5 09/18/2005 06:20:00 1.5 0.5 3 0.4 1.2 0.6 2.6 0.4 0.6 0.3 1.5 0.4 148 15 137 255 4.9 0 5 4.8 09/18/2005 06:30:00 1.8 0.3 2.6 0.7 1.5 0.3 2.3 0.4 0.8 0.4 1.9 0.4 142 8 134 255 4.6 0 5 4.5 09/18/2005 06:40:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 0.7 0.4 1.9 0.4 133 13 143 255 4.6 0 4.8 4.3 09/18/2005 06:50:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.5 0.4 115 2 124 255 4.4 0 4.8 4.3 09/18/2005 07:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 110 9 94 255 4.4 0 4.8 4.3 09/18/2005 07:10:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 101 9 113 255 4.3 0 4.8 4.3 09/18/2005 07:20:00 1.8 0.4 3 0.7 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 135 9 123 255 4.2 0 4.8 4.3 09/18/2005 07:30:00 2.3 0.5 3.4 1.1 2 0.5 3.4 0.7 1.5 0.5 2.6 0.4 129 13 120 255 4.4 0 5 4.3 09/18/2005 07:40:00 1.6 0.6 3.4 0.4 1.3 0.7 3 0.4 0.7 0.6 2.6 0.4 141 13 131 255 4.7 0.1 5 4.5 09/18/2005 07:50:00 1.5 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.6 0.4 1.9 0.4 123 15 127 255 4.8 0 5.2 4.8 09/18/2005 08:00:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0 0.7 0.4 137 15 84 255 5.3 0.3 6 5 09/18/2005 08:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 89 6 97 255 6.7 0.4 7.3 6 09/18/2005 08:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.3 1.9 0.4 93 0 93 255 7.3 0.2 7.8 7.3 09/18/2005 08:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 93 0 93 255 8.6 0.6 9.8 7.8 09/18/2005 08:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 29 35 16 255 10.2 0 10.6 9.8 09/18/2005 08:50:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 1 0.5 2.3 0.4 359 17 28 255 10.3 0.1 10.6 10.1 09/18/2005 09:00:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 14 17 7 255 10.2 0 10.6 10.1 09/18/2005 09:10:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 40 23 30 255 10.3 0 10.6 10.1 09/18/2005 09:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 7 18 24 255 10.6 0.2 11.1 10.1 09/18/2005 09:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 353 18 18 255 11.4 0.2 11.7 11.1 09/18/2005 09:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.7 0.3 1.5 0.4 15 16 16 255 11.5 0 11.7 11.4 09/18/2005 09:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 38 26 31 255 11.9 0 12.2 11.7 09/18/2005 10:00:00 1.4 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 17 13 44 255 12.2 0 12.2 11.9 09/18/2005 10:10:00 2 0.5 3 0.4 1.8 0.6 3 0.4 1.7 0.7 3 0.4 311 24 318 255 12.1 0.3 12.5 11.4 09/18/2005 10:20:00 1.4 0.5 3 0.4 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 307 33 300 255 11.3 0.1 11.9 11.1 09/18/2005 10:30:00 1.4 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.1 0.7 3 0.4 296 47 335 255 12.1 0 12.7 11.7 09/18/2005 10:40:00 1.5 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1 0.6 3 0.4 320 18 309 255 12.1 0 12.7 11.9 09/18/2005 10:50:00 2.9 0.6 3.8 1.1 2.8 0.6 3.8 0.7 2.5 0.7 3.8 0.4 305 12 311 255 11.9 0.2 12.7 11.7 09/18/2005 11:00:00 3 0.5 4.2 1.5 2.8 0.5 3.8 1.1 2.4 0.7 3.8 0.7 308 12 323 255 11.7 0.1 12.2 11.7 09/18/2005 11:10:00 2.4 0.7 3.8 0.7 2.2 0.7 3.4 0.4 1.9 0.9 4.2 0.4 305 21 304 255 11.7 0 12.2 11.7 09/18/2005 11:20:00 2.5 0.8 4.2 0.7 2.3 0.9 3.8 0.4 1.9 1 3.8 0.4 300 21 293 255 11.6 0.1 11.9 11.4 09/18/2005 11:30:00 2.4 0.7 3.8 0.7 2.2 0.8 3.8 0.4 1.6 0.8 3.4 0.4 311 14 313 255 11.5 0 11.9 11.4 09/18/2005 11:40:00 2.5 0.8 4.6 0.7 2.3 0.9 4.2 0.4 1.9 1 4.2 0.4 298 22 307 255 11.5 0 11.7 11.4 09/18/2005 11:50:00 2.4 0.6 4.6 0.7 2.3 0.7 4.6 0.4 1.8 0.8 3.8 0.4 303 15 322 255 11.3 0 11.4 11.1 09/18/2005 12:00:00 2.5 0.5 3.8 1.5 2.3 0.5 3.8 0.7 2 0.5 3.4 0.7 311 15 293 255 11.4 0 11.7 11.4 09/18/2005 12:10:00 1.5 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 306 15 303 255 11.6 0 11.9 11.4 09/18/2005 12:20:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 301 18 296 255 11.9 0.1 11.9 11.7 09/18/2005 12:30:00 1.8 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 320 19 305 255 12 0 12.2 11.9 09/18/2005 12:40:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1.4 0.6 3 0.4 295 22 297 255 12.3 0 12.5 12.2 09/18/2005 12:50:00 2.2 0.7 4.2 0.7 1.8 0.8 4.2 0.4 1.5 0.8 3.4 0.4 309 30 301 255 12.9 0.4 14.1 12.2 09/18/2005 13:00:00 2 0.9 4.2 0.7 1.7 1 4.2 0.4 1.4 1 3.8 0.4 307 30 284 255 13.7 0 14.4 13.5 09/18/2005 13:10:00 2.6 0.7 4.2 0.7 2.3 0.7 4.2 0.4 2 0.7 3.8 0.4 325 23 339 255 14.2 0.1 14.9 13.5 09/18/2005 13:20:00 2.3 0.5 3.8 0.7 2 0.5 3.8 0.4 1.7 0.8 3.4 0.4 322 28 3 255 14.5 0 15.2 14.4 09/18/2005 13:30:00 2.1 0.9 3.8 0.4 1.8 0.9 4.2 0.4 1.6 1 4.6 0.4 304 69 312 255 15.7 0.5 16.8 14.6 09/18/2005 13:40:00 2.7 0.8 4.6 0.4 2.4 0.8 4.6 0.4 2 0.9 4.6 0.4 313 30 292 255 15.7 0 16.3 15.5 09/18/2005 13:50:00 2.6 1 5.3 0.4 2.3 1.1 4.9 0.4 2 1.1 4.6 0.4 319 20 318 255 15.7 0.3 16.6 15.5 09/18/2005 14:00:00 1.5 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 315 33 268 255 14.8 0.3 15.5 14.4 09/18/2005 14:10:00 1.8 1 4.2 0.4 1.6 1 4.6 0.4 1.5 1 3.8 0.4 306 23 279 255 15 0.4 15.7 14.4 09/18/2005 14:20:00 1.5 0.8 3.8 0.4 1.1 0.7 3.4 0.4 0.9 0.7 3.4 0.4 274 45 225 255 14.8 0 15.2 14.6 09/18/2005 14:30:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 1 0.6 3 0.4 269 51 281 255 14.7 0 15.2 14.4 09/18/2005 14:40:00 1.9 0.6 4.2 0.4 1.8 0.7 3.8 0.4 1.4 0.7 3.8 0.4 233 27 247 255 14.4 0.1 14.9 14.1 09/18/2005 14:50:00 1.8 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1 0.8 4.2 0.4 262 45 250 255 14.2 0.1 14.6 13.8 09/18/2005 15:00:00 2.3 0.7 4.2 0.7 2.1 0.8 4.2 0.4 1.8 0.6 3.8 0.7 254 21 256 255 14.1 0.1 14.6 13.8 09/18/2005 15:10:00 2.3 0.8 4.2 0.4 2.2 0.9 4.2 0.4 1.8 0.9 4.2 0.4 277 22 260 255 14.2 0.1 14.9 13.8 09/18/2005 15:20:00 2.2 0.7 4.6 0.7 2.1 0.8 4.2 0.4 1.5 0.9 4.2 0.4 284 22 286 255 14.6 0 15.2 14.4 09/18/2005 15:30:00 1.7 0.8 4.2 0.4 1.4 0.9 3.8 0.4 1.2 0.8 3.4 0.4 307 35 354 255 14.6 0.2 15.2 14.6 09/18/2005 15:40:00 1.3 0.6 3 0.4 1 0.6 3 0.4 0.8 0.6 2.6 0.4 304 19 306 255 14.6 0.2 15.2 14.4 09/18/2005 15:50:00 1.8 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.1 0.6 2.6 0.4 297 38 311 255 14.3 0 14.9 14.4 09/18/2005 16:00:00 2.4 1 4.9 0.4 2.2 1 4.2 0.4 1.6 0.9 4.2 0.4 275 38 259 255 14.8 0.1 15.2 14.6 09/18/2005 16:10:00 2.9 0.8 5.7 0.4 2.7 0.9 5.7 0.4 2.3 0.9 4.9 0.7 295 16 268 255 14.9 0 15.2 14.9 09/18/2005 16:20:00 3.7 1 6.1 1.5 3.4 1 6.1 1.5 2.6 1 4.9 0.4 309 16 310 255 14.6 0 14.9 14.6 09/18/2005 16:30:00 3.2 0.8 4.9 0.7 3 0.7 4.6 1.1 2.4 0.9 4.9 0.4 300 18 304 255 14.7 0 15.2 14.6 09/18/2005 16:40:00 3.3 0.9 4.9 1.1 3.2 0.9 4.9 0.7 2.6 1 4.9 0.4 294 20 288 255 14.8 0 15.2 14.6 09/18/2005 16:50:00 2.4 0.8 4.6 1.1 2.3 0.8 4.6 0.4 2 0.8 4.6 0.4 282 27 303 255 14.9 0 15.2 14.9 09/18/2005 17:00:00 3.8 0.8 6.5 2.3 3.7 0.8 6.5 1.9 3.2 0.8 6.1 1.1 285 17 266 255 14.6 0.1 15.2 14.4 09/18/2005 17:10:00 2.8 0.7 4.6 1.1 2.7 0.7 4.6 0.7 2.3 0.8 4.2 0.4 288 17 294 255 14.1 0 14.6 13.8 09/18/2005 17:20:00 2.9 0.7 4.6 0.7 2.7 0.7 4.2 0.7 2.2 0.8 4.2 0.4 287 19 202 255 13.9 0 14.4 13.5 09/18/2005 17:30:00 2.6 0.8 4.2 0.4 2.4 0.9 4.2 0.4 2.1 0.8 3.8 0.4 292 15 291 255 13.6 0 13.8 13.3 09/18/2005 17:40:00 2.2 0.7 4.6 0.7 1.9 0.8 4.2 0.4 1.5 0.8 3.8 0.4 286 17 260 255 13.3 0 13.8 13 09/18/2005 17:50:00 2.2 0.6 4.2 1.1 2 0.6 3.8 0.7 1.3 0.6 3.4 0.4 267 14 260 255 12.7 0 13 12.7 09/18/2005 18:00:00 2 0.8 3.8 0.4 1.9 0.8 4.2 0.4 1.3 0.7 3.4 0.4 270 17 270 255 12.6 0 12.7 12.5 09/18/2005 18:10:00 1.9 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.3 0.6 2.6 0.4 264 19 268 255 12.5 0 12.7 12.5 09/18/2005 18:20:00 1.7 0.8 4.2 0.4 1.6 0.8 3.8 0.4 1.2 0.8 3.8 0.4 246 15 273 255 12.7 0 12.7 12.5 09/18/2005 18:30:00 2 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.2 0.7 3 0.4 244 14 253 255 12.8 0 12.7 12.7 09/18/2005 18:40:00 1.7 0.7 3.4 0.4 1.6 0.7 3 0.4 1 0.6 3 0.4 251 17 255 255 12.7 0 12.7 12.5 09/18/2005 18:50:00 1.8 0.6 3 0.4 1.6 0.6 2.6 0.4 0.9 0.5 2.3 0.4 232 15 249 255 12.4 0 12.7 12.2 09/18/2005 19:00:00 1.8 0.4 3 0.7 1.7 0.4 3 0.7 0.8 0.4 1.9 0.4 225 8 238 255 11.9 0.1 12.2 11.7 09/18/2005 19:10:00 1.9 0.5 3 0.7 1.7 0.5 2.6 0.4 0.7 0.4 2.3 0.4 222 7 232 255 11.6 0 11.7 11.4 09/18/2005 19:20:00 2 0.5 3.4 0.7 1.8 0.5 3 0.7 0.9 0.5 1.9 0.4 230 12 228 255 11.3 0 11.4 11.1 09/18/2005 19:30:00 1.5 0.6 3 0.4 1.3 0.7 3 0.4 0.5 0.3 1.9 0.4 240 11 241 255 11.1 0 11.4 11.1 09/18/2005 19:40:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 0.6 0.4 2.3 0.4 242 10 265 255 11.1 0 11.1 11.1 09/18/2005 19:50:00 1.8 0.6 3.4 0.4 1.6 0.5 3 0.4 0.8 0.4 1.9 0.4 231 13 241 255 11.1 0 11.1 10.9 09/18/2005 20:00:00 1.9 0.5 3 0.7 1.6 0.6 3 0.4 0.9 0.5 2.6 0.4 235 13 241 255 11 0 11.1 10.9 09/18/2005 20:10:00 1.8 0.4 3 0.7 1.5 0.5 3 0.4 0.8 0.4 1.9 0.4 241 13 229 255 10.7 0 11.1 10.6 09/18/2005 20:20:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.4 0.6 3.4 0.4 232 12 214 255 10.5 0 10.6 10.3 09/18/2005 20:30:00 2.6 0.5 3.8 1.1 2.4 0.5 3.4 1.1 1.3 0.5 3 0.4 227 15 235 255 10.5 0 10.6 10.3 09/18/2005 20:40:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 219 21 215 255 10.4 0 10.6 10.3 09/18/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 141 35 255 255 10.2 0 10.3 10.1 09/18/2005 21:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 72 14 108 255 10 0 10.3 9.8 09/18/2005 21:10:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 130 39 108 255 9.7 0 9.8 9.6 09/18/2005 21:20:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 255 13 266 255 9.6 0 9.6 9.6 09/18/2005 21:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 82 10 83 255 9.5 0 9.6 9.6 09/18/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 0 255 255 9.6 0 9.6 9.6 09/18/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 83 0 255 255 9.5 0 9.6 9.6 09/18/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 0 255 255 9.5 0 9.6 9.3 09/18/2005 22:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 83 0 255 255 9.4 0 9.6 9.3 09/18/2005 22:20:00 1.1 0.3 1.5 0.4 0.8 0.2 1.5 0.4 0.4 0.1 0.7 0.4 91 14 83 255 9.2 0 9.3 9 09/18/2005 22:30:00 1.3 0.2 1.9 0.7 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 115 0 115 255 9.4 0 9.6 9.3 09/18/2005 22:40:00 1 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 115 0 115 255 9.5 0 9.6 9.3 09/18/2005 22:50:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 115 255 9.5 0 9.6 9.6 09/18/2005 23:00:00 0.9 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 115 255 9.5 0 9.6 9.6 09/18/2005 23:10:00 0.9 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 96 35 115 255 9.5 0 9.6 9.6 09/18/2005 23:20:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 34 0 34 255 9.5 0 9.6 9.3 09/18/2005 23:30:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 16 3 34 255 9.4 0 9.6 9.3 09/18/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 255 255 9.2 0 9.3 9 09/18/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 255 255 9.1 0 9.3 9 09/19/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 16 0 255 255 9.1 0 9.3 9 09/19/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 16 0 255 255 9.2 0 9.3 9 09/19/2005 00:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.1 0.2 1.5 0.4 133 30 145 255 9.4 0 9.6 9.3 09/19/2005 00:30:00 1.1 0.7 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.3 1.9 0.4 161 0 160 255 9.4 0 9.6 9.3 09/19/2005 00:40:00 1.9 0.3 2.6 0.7 1.8 0.2 2.3 1.1 1.5 0.3 2.3 0.4 167 7 168 255 9.3 0 9.6 9.3 09/19/2005 00:50:00 1.7 0.3 2.3 0.7 1.9 0.4 3 1.1 1.6 0.4 2.3 0.7 173 6 164 255 9.2 0 9.3 9 09/19/2005 01:00:00 1.9 0.4 3 0.7 2.2 0.5 3 0.7 1.6 0.5 2.6 0.4 182 13 197 255 9 0 9.3 9 09/19/2005 01:10:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 185 13 184 255 8.9 0 9 9 09/19/2005 01:20:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.5 0.4 1.9 0.4 160 0 160 255 8.9 0 9 9 09/19/2005 01:30:00 1.4 0.3 1.9 0.7 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 158 5 160 255 8.9 0 9 8.8 09/19/2005 01:40:00 1.8 0.3 2.6 1.1 1.5 0.3 2.3 0.7 0.9 0.3 1.5 0.4 150 4 148 255 8.9 0 9 9 09/19/2005 01:50:00 2 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.3 0.4 2.3 0.4 145 5 148 255 9 0 9 9 09/19/2005 02:00:00 1.9 0.2 2.3 1.1 1.6 0.3 2.3 1.1 1.2 0.4 1.9 0.4 150 5 139 255 9.2 0 9.3 9 09/19/2005 02:10:00 1.8 0.4 2.6 0.4 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 162 12 158 255 9.2 0 9.3 9.3 09/19/2005 02:20:00 2 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.2 0.4 2.3 0.4 162 5 160 255 9.3 0 9.3 9 09/19/2005 02:30:00 2.1 0.3 2.6 1.5 1.9 0.2 2.3 1.1 1.2 0.4 1.9 0.4 158 5 158 255 9.3 0 9.3 9.3 09/19/2005 02:40:00 2.1 0.3 2.6 1.5 1.8 0.3 2.3 1.1 1.3 0.4 1.9 0.4 153 5 147 255 9.2 0 9.3 9 09/19/2005 02:50:00 2 0.2 2.6 1.1 1.7 0.2 2.3 0.7 1 0.4 1.9 0.4 153 3 152 255 9.1 0 9.3 9 09/19/2005 03:00:00 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 0.5 0.2 1.5 0.4 150 2 152 255 9 0 9 9 09/19/2005 03:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 149 0 149 255 8.9 0 9 9 09/19/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 149 0 255 255 8.9 0 9 9 09/19/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 149 0 255 255 8.9 0 9 8.8 09/19/2005 03:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 149 0 149 255 8.9 0 9 8.8 09/19/2005 03:50:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 145 6 136 255 8.7 0 8.8 8.8 09/19/2005 04:00:00 1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 132 10 137 255 8.7 0 8.8 8.5 09/19/2005 04:10:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 104 8 87 255 8.5 0 8.8 8.5 09/19/2005 04:20:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 82 32 49 255 8.4 0 8.5 8.3 09/19/2005 04:30:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 56 0 57 255 8.3 0 8.5 8.3 09/19/2005 04:40:00 1.5 0.3 2.3 0.7 1 0.4 1.9 0.4 0.5 0.3 1.1 0.4 62 6 56 255 8.1 0 8.3 8 09/19/2005 04:50:00 1.2 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 64 0 64 255 8 0 8.3 7.8 09/19/2005 05:00:00 1.4 0.3 2.3 0.7 0.9 0.3 1.9 0.4 0.5 0.2 1.5 0.4 64 0 64 255 7.8 0 8 7.5 09/19/2005 05:10:00 1.1 0.2 1.5 0.4 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 64 0 64 255 7.6 0 8 7.5 09/19/2005 05:20:00 1.1 0.3 1.9 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 64 0 64 255 7.5 0 7.8 7.5 09/19/2005 05:30:00 1.3 0.3 1.9 0.7 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 64 0 64 255 7.3 0 7.8 7.3 09/19/2005 05:40:00 1.3 0.2 1.9 0.7 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 78 20 105 255 7.3 0 7.3 7 09/19/2005 05:50:00 1.2 0.2 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 89 13 115 255 7 0 7.3 7 09/19/2005 06:00:00 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 96 0 96 255 6.8 0 7.3 6.7 09/19/2005 06:10:00 1.3 0.3 2.3 0.7 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 121 18 144 255 6.6 0 6.7 6.5 09/19/2005 06:20:00 1.2 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.6 0.3 1.5 0.4 136 8 144 255 6.2 0 6.5 6 09/19/2005 06:30:00 1.6 0.4 2.6 0.7 1.1 0.5 2.3 0.4 1 0.4 1.9 0.4 125 5 119 255 6 0 6 5.7 09/19/2005 06:40:00 1.8 0.3 2.6 1.1 1.4 0.4 2.3 0.7 0.8 0.4 1.9 0.4 94 14 77 255 5.7 0 6 5.7 09/19/2005 06:50:00 1.6 0.2 2.3 1.1 1.1 0.2 1.5 0.7 0.6 0.4 1.5 0.4 106 15 91 255 5.7 0.1 6.2 5.7 09/19/2005 07:00:00 2 0.4 3 0.7 1.6 0.5 2.6 0.4 1.8 0.4 3 0.4 133 7 134 255 5.8 0.1 6.2 5.7 09/19/2005 07:10:00 1.8 0.5 2.6 0.7 1.4 0.5 2.3 0.4 0.9 0.5 2.3 0.4 124 10 132 255 5.8 0 6.2 5.7 09/19/2005 07:20:00 1.3 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 132 8 145 255 5.9 0 6.2 5.7 09/19/2005 07:30:00 1.9 0.3 2.6 1.1 1.6 0.3 2.6 0.7 1.1 0.5 2.3 0.4 133 12 133 255 6.5 0.2 7 6.2 09/19/2005 07:40:00 1.6 0.3 2.3 1.1 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 111 3 115 255 7.3 0.2 7.8 7 09/19/2005 07:50:00 1.3 0.3 1.9 0.7 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 100 4 109 255 7.9 0.1 8.3 7.5 09/19/2005 08:00:00 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 112 24 97 255 7.9 0 8.3 7.8 09/19/2005 08:10:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 141 7 142 255 7.9 0 8 7.8 09/19/2005 08:20:00 1.5 0.3 2.3 0.4 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 110 10 100 255 8.1 0 8.3 8 09/19/2005 08:30:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 110 13 129 255 8.3 0 8.5 8.3 09/19/2005 08:40:00 0.8 0.2 1.5 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 101 0 101 255 8.4 0 8.5 8.3 09/19/2005 08:50:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 0 101 255 8.7 0.1 9 8.5 09/19/2005 09:00:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 65 33 29 255 9.7 0.4 10.6 9 09/19/2005 09:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 13 24 352 255 11.1 0.2 11.7 10.6 09/19/2005 09:20:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 12 15 9 255 12.1 0.3 12.7 11.4 09/19/2005 09:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.5 2.3 0.4 358 12 5 255 13.2 0.3 13.8 12.7 09/19/2005 09:40:00 1.3 0.3 2.3 0.4 0.9 0.4 1.9 0.4 1.2 0.4 1.9 0.4 15 11 3 255 13.2 0.4 13.8 12.5 09/19/2005 09:50:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 11 14 348 255 12.4 0 12.5 12.2 09/19/2005 10:00:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 347 19 346 255 12.4 0 12.5 12.2 09/19/2005 10:10:00 1.4 0.4 2.6 0.4 1 0.4 1.9 0.4 1 0.5 2.3 0.4 3 22 46 255 12.3 0 12.5 12.2 09/19/2005 10:20:00 1.8 0.3 2.6 0.7 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 18 12 17 255 12.1 0 12.5 11.9 09/19/2005 10:30:00 1.7 0.3 2.3 1.1 1.3 0.4 2.3 0.4 1.2 0.4 1.9 0.4 17 13 22 255 12 0 12.2 11.9 09/19/2005 10:40:00 1.4 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 353 11 351 255 12.3 0 12.7 12.2 09/19/2005 10:50:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 2 13 340 255 12.5 0 12.7 12.5 09/19/2005 11:00:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 4 18 352 255 12.6 0 12.7 12.5 09/19/2005 11:10:00 1.2 0.3 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 23 16 68 255 12.9 0 13 12.7 09/19/2005 11:20:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 39 21 26 255 12.9 0.1 13.3 12.7 09/19/2005 11:30:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 53 21 45 255 13.5 0.1 13.8 13.3 09/19/2005 11:40:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.8 0.4 1.5 0.4 61 26 77 255 13.9 0 14.6 13.8 09/19/2005 11:50:00 1.2 0.6 3 0.4 1 0.6 3 0.4 0.8 0.5 2.3 0.4 16 69 262 255 14.2 0 14.9 13.8 09/19/2005 12:00:00 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 231 47 295 255 14.7 0.2 15.5 14.4 09/19/2005 12:10:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 274 41 263 255 15 0 15.7 14.9 09/19/2005 12:20:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 1.1 0.7 2.6 0.4 215 36 218 255 14.9 0.1 15.7 14.6 09/19/2005 12:30:00 1.3 0.9 3.8 0.4 1.1 0.8 3.4 0.4 0.9 0.8 3.4 0.4 267 49 291 255 14.8 0 15.2 14.6 09/19/2005 12:40:00 1 0.8 3.4 0.4 0.9 0.7 3 0.4 0.8 0.6 3 0.4 242 69 279 255 14.9 0 15.5 14.9 09/19/2005 12:50:00 1.8 0.8 3.4 0.4 1.7 0.8 3 0.4 1.3 0.7 3 0.4 205 41 225 255 15.4 0.1 16 14.9 09/19/2005 13:00:00 2 0.6 3.8 0.4 1.9 0.6 3.4 0.4 1.5 0.6 3.4 0.4 215 22 237 255 15.5 0 16 15.5 09/19/2005 13:10:00 2.4 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1.7 0.6 3.4 0.4 234 30 202 255 15.8 0.2 16.6 15.5 09/19/2005 13:20:00 1.6 0.9 3.8 0.4 1.3 0.8 3.4 0.4 1.2 0.8 3.8 0.4 318 20 323 255 16.1 0.2 16.8 15.7 09/19/2005 13:30:00 1.7 0.8 3.8 0.4 1.5 0.9 3.8 0.4 1.2 0.8 3.4 0.4 258 36 274 255 15.5 0.2 16.3 15.2 09/19/2005 13:40:00 1.1 0.8 3 0.4 1 0.8 3.8 0.4 0.8 0.6 3 0.4 272 58 264 255 15.5 0.3 16.3 15.2 09/19/2005 13:50:00 2 0.7 3.4 0.4 1.8 0.7 3 0.4 1.5 0.8 3 0.4 252 39 257 255 16.1 0 16.6 16 09/19/2005 14:00:00 2.9 0.8 4.6 0.7 2.7 0.9 4.6 0.4 2.3 0.8 4.6 0.4 305 21 263 255 15.9 0 16.6 15.7 09/19/2005 14:10:00 2.8 0.8 4.6 0.7 2.7 0.8 4.6 0.7 2.2 0.9 4.6 0.4 287 33 307 255 15.6 0 16.3 15.5 09/19/2005 14:20:00 2.6 0.7 4.6 0.7 2.4 0.8 4.2 0.4 2.1 0.8 4.6 0.4 269 23 267 255 15.9 0.2 16.6 15.7 09/19/2005 14:30:00 3.3 0.9 5.7 0.7 3.2 1 5.7 0.4 2.5 1 4.6 0.4 289 24 282 255 15.9 0 16.6 15.7 09/19/2005 14:40:00 2.1 1 4.9 0.4 1.9 1.1 4.6 0.4 1.5 1 4.6 0.4 282 39 257 255 15.9 0 16.6 15.7 09/19/2005 14:50:00 2.6 1 4.9 0.4 2.3 1 4.6 0.4 2 0.9 4.6 0.4 276 19 268 255 15.6 0.2 16.6 15.2 09/19/2005 15:00:00 2.5 0.8 4.2 0.7 2.2 0.9 4.2 0.4 2 0.9 4.2 0.4 284 21 276 255 15.3 0.1 16 15.2 09/19/2005 15:10:00 2.5 1 4.9 0.7 2.3 1 4.9 0.4 1.9 1 4.2 0.4 280 23 253 255 15 0 15.5 14.9 09/19/2005 15:20:00 1.7 0.8 3.4 0.4 1.5 0.9 3.8 0.4 1 0.7 2.6 0.4 297 19 326 255 15.2 0.1 15.7 15.2 09/19/2005 15:30:00 1.6 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1.2 0.8 3 0.4 300 22 314 255 15.4 0 15.7 15.2 09/19/2005 15:40:00 2.4 0.9 4.6 0.4 2.1 1 4.6 0.4 1.7 1 3.8 0.4 311 16 295 255 15.9 0.1 16.6 15.7 09/19/2005 15:50:00 3 0.7 4.9 1.1 2.7 0.7 4.9 0.4 2.2 0.7 4.2 0.7 308 17 296 255 16.2 0 16.6 16 09/19/2005 16:00:00 2.4 0.9 4.2 0.4 2 0.9 3.8 0.4 1.6 1 3.8 0.4 311 30 317 255 16.4 0.1 16.8 16.3 09/19/2005 16:10:00 2.9 0.7 4.6 1.1 2.5 0.7 4.2 0.7 2 0.7 4.2 0.4 320 20 325 255 16.1 0.2 16.8 15.7 09/19/2005 16:20:00 2.1 0.7 3.8 0.7 1.8 0.8 3.4 0.4 1.6 0.8 3.4 0.4 303 21 305 255 15.5 0 16 15.5 09/19/2005 16:30:00 2.1 0.6 3.8 0.4 1.8 0.7 3.8 0.4 1.4 0.7 3.8 0.4 291 20 295 255 15.5 0 16 15.5 09/19/2005 16:40:00 2.4 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 294 13 309 255 15.5 0 16 15.5 09/19/2005 16:50:00 1.5 0.9 3.8 0.4 1.2 0.8 3.4 0.4 1.1 0.6 2.6 0.4 309 33 304 255 15.5 0 16.3 15.5 09/19/2005 17:00:00 2.4 0.5 3.8 1.1 2.1 0.6 3.4 0.7 1.6 0.7 3.4 0.4 293 17 282 255 15.5 0.1 16.3 15.2 09/19/2005 17:10:00 2.1 0.6 3.4 0.4 1.9 0.7 3.4 0.4 1.5 0.8 3 0.4 274 26 291 255 15.5 0 16 15.5 09/19/2005 17:20:00 2 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3 0.4 299 27 253 255 15.3 0 15.7 15.2 09/19/2005 17:30:00 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 1.3 0.7 3.4 0.4 263 13 259 255 15 0 15.7 15.2 09/19/2005 17:40:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 267 32 299 255 14.9 0 15.5 14.9 09/19/2005 17:50:00 1.4 0.8 3.4 0.4 1 0.7 3.4 0.4 0.8 0.4 2.3 0.4 258 21 297 255 14.8 0 15.5 14.9 09/19/2005 18:00:00 1.2 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 267 15 233 255 14.8 0 15.5 14.6 09/19/2005 18:10:00 1.6 1 4.2 0.4 1.3 1 3.8 0.4 1 0.9 4.2 0.4 266 20 258 255 14.6 0 15.2 14.6 09/19/2005 18:20:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 274 15 300 255 14.5 0 15.2 14.4 09/19/2005 18:30:00 1.4 1 3.4 0.4 1.2 0.9 3 0.4 1 0.8 3 0.4 347 56 44 255 14.2 0.1 14.9 13.8 09/19/2005 18:40:00 1.8 0.5 3 0.7 1.4 0.5 3 0.4 1.4 0.5 2.6 0.4 67 16 44 255 13.7 0.1 14.6 13.3 09/19/2005 18:50:00 4.1 1.4 6.8 1.5 3.8 1.5 6.5 1.1 3.3 1.3 6.1 0.7 56 17 40 255 13.3 0 13.5 13 09/19/2005 19:00:00 3.8 1 5.7 1.5 3.6 1 5.7 1.1 2.9 1 5.3 0.7 31 16 48 255 12.8 0 13 12.7 09/19/2005 19:10:00 3.2 1 5.7 1.5 2.9 1.1 5.3 1.1 2.6 1 5.3 0.4 42 19 24 255 12.6 0 12.7 12.5 09/19/2005 19:20:00 2.1 0.5 3.4 0.4 1.8 0.6 3 0.7 1.4 0.6 2.6 0.4 49 17 51 255 12.3 0 12.5 12.2 09/19/2005 19:30:00 1.8 0.8 3.8 0.4 1.5 0.8 3.4 0.4 1.4 0.7 3 0.4 90 32 107 255 12 0.2 12.2 11.7 09/19/2005 19:40:00 2.1 0.6 3.4 1.1 1.8 0.7 3.4 0.4 1.6 0.6 3.4 0.4 66 29 39 255 11.6 0 11.7 11.4 09/19/2005 19:50:00 1.9 0.7 3.4 0.4 1.6 0.8 3 0.4 1 0.7 3 0.4 12 12 35 255 11.2 0 11.4 11.1 09/19/2005 20:00:00 1.6 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 349 14 351 255 10.8 0.1 11.1 10.6 09/19/2005 20:10:00 1.8 0.4 2.6 0.4 1.2 0.4 2.6 0.4 0.6 0.4 1.5 0.4 351 21 339 255 10.5 0 10.6 10.6 09/19/2005 20:20:00 1.5 0.6 2.6 0.4 1.3 0.6 2.3 0.4 1.1 0.5 2.6 0.4 115 33 106 255 10.4 0 10.6 10.3 09/19/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 255 255 10.3 0 10.6 10.3 09/19/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 255 255 10.2 0 10.3 10.1 09/19/2005 20:50:00 0.8 0.4 1.5 0.4 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 152 9 165 255 10.1 0 10.3 9.8 09/19/2005 21:00:00 1.6 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1.2 0.3 1.9 0.4 145 1 145 255 10 0 10.1 9.8 09/19/2005 21:10:00 2.2 0.4 3 1.5 1.9 0.4 2.6 1.1 1.5 0.4 2.6 0.4 158 9 142 255 9.9 0 10.1 9.8 09/19/2005 21:20:00 2.7 0.3 3.4 1.9 2.5 0.3 3 1.5 1.9 0.4 2.6 1.1 136 7 146 255 9.8 0 10.1 9.8 09/19/2005 21:30:00 3.1 0.4 4.2 1.9 2.9 0.4 4.2 1.9 2.2 0.5 3.8 0.7 118 7 111 255 9.9 0 10.1 9.8 09/19/2005 21:40:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.5 2.4 0.5 3.4 1.1 108 9 103 255 9.8 0 9.8 9.8 09/19/2005 21:50:00 3.4 0.6 4.6 1.9 3.2 0.6 4.6 1.1 2.1 0.6 3.8 0.4 107 11 118 255 9.8 0 9.8 9.8 09/19/2005 22:00:00 3.7 0.5 4.9 2.3 3.5 0.5 4.9 1.9 2.4 0.7 4.2 0.7 102 10 112 255 9.7 0 9.8 9.6 09/19/2005 22:10:00 3.4 0.5 4.6 1.9 3.2 0.5 4.6 1.1 2.2 0.6 3.4 0.7 106 12 90 255 9.6 0 9.6 9.6 09/19/2005 22:20:00 3.6 0.5 4.9 2.3 3.5 0.5 4.9 1.9 2.3 0.6 3.8 0.7 113 12 119 255 9.5 0 9.6 9.6 09/19/2005 22:30:00 3.4 0.7 4.9 1.1 3.3 0.7 4.9 1.5 2.2 0.7 4.2 0.4 115 14 111 255 9.6 0 9.8 9.6 09/19/2005 22:40:00 2.5 0.8 4.2 0.7 2.2 0.9 3.8 0.4 1.4 0.8 3.4 0.4 96 45 131 255 9.6 0 9.8 9.3 09/19/2005 22:50:00 1.5 0.4 2.6 0.4 1.1 0.5 2.6 0.4 0.4 0.2 1.5 0.4 55 33 7 255 8.9 0.2 9.6 8.5 09/19/2005 23:00:00 0.9 0.4 1.9 0.4 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 41 51 8 255 8.3 0.1 8.8 8 09/19/2005 23:10:00 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 124 11 110 255 7.9 0 8.3 7.8 09/19/2005 23:20:00 2 0.3 3 1.1 1.7 0.3 2.6 0.4 0.9 0.4 1.5 0.4 107 6 106 255 7.6 0.1 7.8 7.5 09/19/2005 23:30:00 2.4 0.3 3 1.9 2.1 0.3 3 1.5 1.4 0.4 2.3 0.4 94 7 87 255 7.4 0 7.5 7.3 09/19/2005 23:40:00 1.9 0.4 3 1.1 1.6 0.5 2.6 0.4 0.6 0.4 1.9 0.4 89 2 86 255 7.2 0 7.5 7 09/19/2005 23:50:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.4 0.4 0.2 1.1 0.4 91 18 89 255 7.1 0 7.3 7 09/20/2005 00:00:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 143 8 163 255 6.8 0 7.5 6.7 09/20/2005 00:10:00 1.8 0.3 2.6 0.7 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 132 15 148 255 6.7 0 6.7 6.7 09/20/2005 00:20:00 1.8 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.1 0.5 1.9 0.4 136 14 150 255 6.2 0.1 6.7 6 09/20/2005 00:30:00 2.5 0.4 3 1.1 2.2 0.4 3 0.7 1.4 0.4 2.3 0.4 134 15 148 255 6 0 6.2 5.7 09/20/2005 00:40:00 2.2 0.5 3 0.7 1.9 0.5 3 0.7 0.9 0.4 1.9 0.4 113 9 109 255 6.2 0 6.2 6 09/20/2005 00:50:00 2.2 0.5 3 0.7 1.9 0.5 2.6 0.4 0.9 0.4 1.9 0.4 107 7 115 255 6.2 0 6.5 6.2 09/20/2005 01:00:00 2.1 0.3 2.6 1.5 1.8 0.4 2.6 1.1 0.9 0.4 1.9 0.4 110 9 99 255 6.4 0 6.7 6.2 09/20/2005 01:10:00 2 0.3 2.6 1.1 1.6 0.3 2.3 0.7 0.7 0.4 1.9 0.4 105 7 105 255 6.7 0 6.7 6.7 09/20/2005 01:20:00 1.7 0.3 2.6 0.7 1.3 0.3 2.3 0.4 0.5 0.3 1.5 0.4 94 6 101 255 6.8 0 7 6.7 09/20/2005 01:30:00 2.1 0.4 3 1.1 1.8 0.4 2.6 0.7 0.9 0.5 2.3 0.4 106 7 111 255 6.9 0 7 7 09/20/2005 01:40:00 1.9 0.4 2.6 1.1 1.5 0.5 2.6 0.4 0.9 0.5 1.9 0.4 99 7 112 255 7 0 7.3 7 09/20/2005 01:50:00 1.6 0.4 2.3 0.7 1.1 0.5 2.3 0.4 0.5 0.3 1.1 0.4 108 8 109 255 7 0 7.3 7 09/20/2005 02:00:00 2.1 0.4 3 0.4 1.9 0.4 2.6 0.4 1.1 0.5 2.3 0.4 108 6 119 255 7.2 0 7.3 7.3 09/20/2005 02:10:00 2.3 0.5 3 0.7 2.1 0.5 2.6 0.4 1.2 0.5 2.3 0.4 105 13 115 255 7.3 0 7.5 7.3 09/20/2005 02:20:00 2.3 0.4 3 1.1 2.1 0.4 2.6 1.1 1.1 0.4 2.3 0.4 89 10 86 255 7.4 0 7.5 7.5 09/20/2005 02:30:00 1.9 0.4 3 0.7 1.6 0.4 2.6 0.7 0.7 0.4 1.9 0.4 104 12 106 255 7.4 0 7.5 7.3 09/20/2005 02:40:00 1.8 0.6 3 0.4 1.6 0.5 2.6 0.4 1 0.5 2.3 0.4 118 15 120 255 7.4 0 7.5 7.3 09/20/2005 02:50:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.8 0.4 1.9 0.4 111 9 126 255 7.6 0 7.8 7.5 09/20/2005 03:00:00 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 0.8 0.4 1.9 0.4 120 10 117 255 7.5 0 7.8 7.5 09/20/2005 03:10:00 2.3 0.5 3.4 1.1 1.9 0.5 3 0.7 1.3 0.5 2.6 0.4 112 11 100 255 7.5 0 7.5 7.5 09/20/2005 03:20:00 2.1 0.5 3.4 0.7 1.8 0.5 3 0.4 1 0.5 2.3 0.4 114 12 111 255 7.6 0 7.5 7.5 09/20/2005 03:30:00 2.3 0.4 3 1.1 2 0.4 3 0.7 1.2 0.5 2.3 0.4 110 7 108 255 7.3 0 7.5 7.3 09/20/2005 03:40:00 2.1 0.5 3 0.4 1.8 0.5 3 0.4 0.9 0.5 2.3 0.4 104 10 92 255 7.1 0 7.3 7 09/20/2005 03:50:00 1.8 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 111 7 102 255 6.7 0 7 6.7 09/20/2005 04:00:00 1.4 0.6 3 0.4 1.1 0.5 3 0.4 0.7 0.5 2.3 0.4 126 9 117 255 6.6 0 6.7 6.2 09/20/2005 04:10:00 2.1 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.2 0.5 2.6 0.4 122 8 109 255 6.4 0 6.7 6.2 09/20/2005 04:20:00 2.6 0.4 3.8 1.5 2.2 0.5 3 0.7 1.3 0.5 2.6 0.4 114 10 122 255 6.6 0 6.7 6.2 09/20/2005 04:30:00 2.7 0.5 3.8 1.5 2.4 0.5 3.4 1.1 1.5 0.5 3 0.4 118 9 113 255 6.6 0 6.7 6.5 09/20/2005 04:40:00 2.2 0.5 3.8 1.1 1.9 0.6 3.4 0.7 1.2 0.5 2.6 0.4 121 12 90 255 6.6 0 6.7 6.5 09/20/2005 04:50:00 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.4 0.2 1.1 0.4 123 11 104 255 6.6 0 6.7 6.5 09/20/2005 05:00:00 1.7 0.8 3.4 0.4 1.5 0.8 3 0.4 1.1 0.7 2.6 0.4 121 10 121 255 6.2 0 6.5 6 09/20/2005 05:10:00 2.1 0.5 3 1.1 1.8 0.5 3 0.4 1 0.5 2.3 0.4 118 12 126 255 6 0 6 5.7 09/20/2005 05:20:00 2.1 0.4 3 1.1 1.8 0.5 3 0.4 1.2 0.5 2.3 0.4 122 10 121 255 5.7 0 6 5.5 09/20/2005 05:30:00 2.4 0.5 3.8 1.1 2.2 0.5 3.4 0.7 1.6 0.5 2.6 0.4 122 9 106 255 5.7 0 6 5.7 09/20/2005 05:40:00 2.1 0.5 3.4 0.7 1.8 0.5 3 0.4 1.2 0.4 2.6 0.4 124 11 124 255 5.8 0 6 5.7 09/20/2005 05:50:00 2.1 0.4 3 1.1 1.8 0.5 3 0.7 1.5 0.4 2.6 0.4 127 9 117 255 5.7 0 5.7 5.7 09/20/2005 06:00:00 1.9 0.4 3 0.7 1.6 0.5 3 0.7 1.5 0.4 2.6 0.4 127 7 118 255 6.1 0.1 6.2 5.7 09/20/2005 06:10:00 1.9 0.5 3 0.7 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 130 12 106 255 6 0 6.2 5.7 09/20/2005 06:20:00 2.4 0.5 3.4 1.1 2.1 0.5 3 0.7 1.5 0.6 2.6 0.4 129 9 131 255 6 0 6.2 5.7 09/20/2005 06:30:00 1 0.7 2.6 0.4 0.8 0.5 2.6 0.4 0.5 0.3 1.5 0.4 135 19 125 255 6 0 6 6 09/20/2005 06:40:00 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 125 9 112 255 6.1 0 6 6 09/20/2005 06:50:00 1.8 0.5 3 0.4 1.4 0.6 2.6 0.4 0.9 0.5 2.3 0.4 118 9 113 255 6.1 0 6.2 6 09/20/2005 07:00:00 2 0.4 3 0.7 1.5 0.5 2.6 0.4 0.7 0.4 2.3 0.4 118 12 113 255 6.2 0 6.2 6 09/20/2005 07:10:00 1.8 0.5 3 0.7 1.3 0.5 2.6 0.4 0.7 0.4 1.5 0.4 120 11 121 255 6.2 0 6.2 6.2 09/20/2005 07:20:00 2.2 0.5 3.4 0.7 1.9 0.5 3.4 0.4 1.1 0.5 2.3 0.4 119 13 93 255 6.7 0.3 7.3 6.2 09/20/2005 07:30:00 2 0.6 3.4 0.4 1.6 0.7 3 0.4 1.2 0.5 2.6 0.4 124 14 113 255 7.1 0 7.3 7 09/20/2005 07:40:00 2.2 0.6 3.8 0.7 1.9 0.7 3.4 0.4 1.6 0.6 3 0.4 139 19 142 255 7.4 0 7.5 7.3 09/20/2005 07:50:00 2.1 0.7 3.4 0.4 1.7 0.7 3 0.4 1.2 0.6 2.6 0.4 158 17 174 255 7.3 0 7.5 7.3 09/20/2005 08:00:00 1.9 0.7 3.4 0.4 1.5 0.7 3 0.4 1.1 0.6 2.6 0.4 151 22 113 255 7.3 0 7.3 7.3 09/20/2005 08:10:00 1.6 0.6 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 163 11 151 255 7.1 0 7.3 7 09/20/2005 08:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 158 9 153 255 7 0 7.3 7 09/20/2005 08:30:00 1.6 0.6 3 0.4 1.2 0.6 2.6 0.4 0.7 0.5 2.3 0.4 129 12 113 255 7.2 0 7.3 7 09/20/2005 08:40:00 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 1 0.6 2.3 0.4 122 8 116 255 7.7 0.1 8 7.3 09/20/2005 08:50:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 116 5 122 255 8.1 0 8.3 7.8 09/20/2005 09:00:00 1.4 0.5 1.9 0.4 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 141 15 142 255 8.3 0 8.5 8.3 09/20/2005 09:10:00 1.5 0.3 1.9 0.7 1.2 0.4 1.9 0.4 0.8 0.4 1.5 0.4 169 11 149 255 8.5 0.1 9 8.5 09/20/2005 09:20:00 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 173 14 167 255 9.6 0.6 10.9 8.8 09/20/2005 09:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 182 22 209 255 11.1 0 11.1 10.9 09/20/2005 09:40:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 186 2 187 255 10.9 0 11.1 10.9 09/20/2005 09:50:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 180 9 188 255 10.7 0 10.9 10.6 09/20/2005 10:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 168 0 168 255 10.7 0 10.9 10.6 09/20/2005 10:10:00 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 157 12 147 255 10.9 0 11.1 10.6 09/20/2005 10:20:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 155 10 151 255 11 0 11.1 10.9 09/20/2005 10:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 178 19 163 255 11.5 0.2 11.9 11.1 09/20/2005 10:40:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 1.9 0.4 229 27 246 255 12 0 12.2 11.7 09/20/2005 10:50:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.5 0.4 286 30 277 255 12.7 0.1 12.7 12.2 09/20/2005 11:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 287 4 262 255 12.4 0.1 12.7 12.5 09/20/2005 11:10:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 281 18 270 255 12.3 0 12.5 12.2 09/20/2005 11:20:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 341 32 342 255 12.3 0 12.5 12.2 09/20/2005 11:30:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.6 2.6 0.4 325 41 305 255 12.7 0.2 13.3 12.5 09/20/2005 11:40:00 2.4 0.9 4.6 0.4 2.2 0.9 4.6 0.4 1.7 0.8 4.2 0.4 262 36 304 255 13.7 0.3 14.4 13 09/20/2005 11:50:00 1.9 0.7 4.2 0.4 1.8 0.7 3.8 0.4 1.5 0.7 3.4 0.4 271 38 318 255 14 0 14.4 13.8 09/20/2005 12:00:00 1.3 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.3 0.6 3 0.4 253 58 206 255 14.3 0 14.6 14.1 09/20/2005 12:10:00 1.8 0.9 4.2 0.4 1.7 0.9 3.4 0.4 1.6 0.8 3.8 0.4 314 32 322 255 14.3 0.2 15.2 14.1 09/20/2005 12:20:00 1.9 1 3.8 0.4 1.8 1 3.8 0.4 1.6 0.9 3.8 0.4 191 28 211 255 14.8 0 15.5 14.6 09/20/2005 12:30:00 2.1 0.7 3.8 0.4 2.1 0.7 4.2 0.4 1.7 0.9 4.2 0.4 180 30 171 255 15 0.2 16 14.6 09/20/2005 12:40:00 2.2 0.8 3.8 0.4 2.2 0.8 3.8 0.4 1.8 0.7 3.8 0.4 183 30 151 255 15.6 0.2 16 15.5 09/20/2005 12:50:00 2.6 0.7 4.2 0.4 2.6 0.8 4.6 0.4 2.4 0.8 4.6 0.4 196 32 192 255 15.4 0.1 16 15.2 09/20/2005 13:00:00 2.2 0.6 3.4 0.4 2.1 0.6 3 0.4 2 0.5 3.4 0.4 178 19 193 255 15.2 0.2 16 14.9 09/20/2005 13:10:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 218 41 209 255 14.6 0.1 15.2 14.4 09/20/2005 13:20:00 1.6 0.9 3.4 0.4 1.4 0.8 3 0.4 1 0.6 3 0.4 217 49 218 255 14.8 0.5 16 14.4 09/20/2005 13:30:00 1.6 0.7 3 0.4 1.4 0.7 3 0.4 1.1 0.6 3 0.4 261 69 216 255 16.6 0.3 17.4 16 09/20/2005 13:40:00 2.1 1.1 4.9 0.4 1.9 1.1 4.6 0.4 1.7 1 4.6 0.4 267 72 314 255 17.5 0.1 17.7 16.8 09/20/2005 13:50:00 2.8 0.7 4.9 0.7 2.5 0.8 4.6 0.4 2.3 0.9 4.9 0.4 303 32 282 255 18.1 0.2 18.5 17.7 09/20/2005 14:00:00 1.7 1.1 4.6 0.4 1.5 1 4.2 0.4 1.3 0.8 3.4 0.4 303 43 307 255 18.5 0 19.1 18.2 09/20/2005 14:10:00 2.4 1 4.6 0.4 2.1 1 4.6 0.4 1.7 0.9 3.8 0.4 311 30 340 255 18.7 0.1 19.4 18.2 09/20/2005 14:20:00 3 0.8 4.9 1.1 2.7 0.8 4.6 0.7 2.3 0.9 4.6 0.4 308 21 294 255 18.7 0 19.1 18.5 09/20/2005 14:30:00 2.7 0.9 4.6 0.7 2.4 1 4.6 0.4 2.1 1 4.6 0.4 302 21 311 255 17.9 0.3 18.8 17.4 09/20/2005 14:40:00 2.4 0.9 4.9 0.4 2.1 0.9 4.6 0.4 1.8 1 4.9 0.4 304 32 303 255 17.5 0 18.2 17.4 09/20/2005 14:50:00 2.8 1.2 6.1 0.4 2.6 1.2 5.7 0.4 2 1 4.6 0.4 284 66 296 255 17.1 0 17.4 16.8 09/20/2005 15:00:00 3.9 1 6.1 1.5 3.8 0.9 5.7 1.5 3 1.1 5.7 0.7 292 22 303 255 16.6 0.2 17.1 16.3 09/20/2005 15:10:00 3.5 0.9 5.7 1.1 3.3 0.9 5.3 0.7 2.8 1.1 4.9 0.4 306 22 307 255 16 0.1 16.8 15.7 09/20/2005 15:20:00 3.3 0.9 4.9 0.7 3.1 0.9 4.9 0.7 2.5 0.9 4.6 0.4 305 17 324 255 15.7 0 16 15.5 09/20/2005 15:30:00 2.9 0.6 4.9 1.1 2.8 0.7 4.6 0.7 2.3 0.8 4.2 0.4 277 22 298 255 15.7 0 16 15.7 09/20/2005 15:40:00 2.1 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.5 0.7 3.4 0.4 315 15 310 255 15.9 0.1 16.6 15.7 09/20/2005 15:50:00 2.3 0.8 4.2 0.4 2.1 0.8 4.2 0.4 1.6 0.9 3.8 0.4 294 22 257 255 16 0 16.6 16 09/20/2005 16:00:00 2.3 0.5 3.8 1.1 2 0.6 3.8 0.7 1.7 0.7 3.8 0.4 317 22 291 255 15.9 0 16.6 15.7 09/20/2005 16:10:00 1.9 1 4.2 0.4 1.5 0.9 4.2 0.4 1 0.7 3.8 0.4 317 30 18 255 15.7 0 16.3 15.7 09/20/2005 16:20:00 2.6 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2 0.8 4.2 0.4 296 29 303 255 15.7 0 16.3 15.5 09/20/2005 16:30:00 1.9 0.9 4.2 0.4 1.6 0.8 3.4 0.4 1.2 0.8 3.4 0.4 331 20 338 255 15.5 0.1 16 15.5 09/20/2005 16:40:00 2.6 0.6 4.2 1.1 2.2 0.7 3.8 0.7 1.5 0.8 3.4 0.4 334 17 323 255 15.5 0 16 15.5 09/20/2005 16:50:00 2 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.2 0.8 3.4 0.4 294 29 279 255 15.5 0 16 15.5 09/20/2005 17:00:00 2.3 0.4 3.4 1.1 2.1 0.5 3.4 0.7 1.8 0.6 3 0.4 281 15 323 255 15.4 0 16 15.5 09/20/2005 17:10:00 1.9 0.6 3.4 0.4 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 290 15 326 255 15.2 0.1 15.7 15.2 09/20/2005 17:20:00 1.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 287 6 285 255 15 0 15.7 14.9 09/20/2005 17:30:00 2.1 0.9 4.2 0.4 1.9 1 4.2 0.4 1.4 0.8 3 0.4 188 51 216 255 14.6 0 15.2 14.6 09/20/2005 17:40:00 2.1 0.5 3.4 0.7 1.9 0.6 3 0.7 1.6 0.5 3 0.4 118 14 115 255 14.4 0 14.6 14.4 09/20/2005 17:50:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 0.7 1.9 0.6 2.6 0.4 97 9 113 255 13.9 0 14.4 13.8 09/20/2005 18:00:00 2.1 0.5 3.4 0.7 1.9 0.5 3 0.7 1.8 0.6 3 0.4 90 9 92 255 13.5 0 13.8 13.3 09/20/2005 18:10:00 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 94 3 94 255 13.1 0.3 13.8 12.7 09/20/2005 18:20:00 2.3 0.4 3.4 1.1 2.1 0.5 3.4 1.1 1.5 0.5 2.6 0.4 84 12 73 255 12.4 0 13 12.2 09/20/2005 18:30:00 2.1 0.4 3 1.5 1.9 0.4 3 1.1 1.3 0.4 2.3 0.4 79 11 85 255 11.9 0.1 12.2 11.7 09/20/2005 18:40:00 2.2 0.4 3.4 1.5 2 0.5 3 1.1 1.3 0.4 2.3 0.4 81 10 81 255 11.2 0.2 11.7 10.9 09/20/2005 18:50:00 2.5 0.3 3.8 1.5 2.4 0.4 3.4 1.5 1.7 0.4 3 0.7 62 9 47 255 10.6 0 10.9 10.6 09/20/2005 19:00:00 2.9 0.4 4.2 1.9 2.8 0.4 4.2 1.9 1.9 0.4 3 0.7 73 8 74 255 10.2 0 10.6 10.1 09/20/2005 19:10:00 2.7 0.5 4.6 1.5 2.6 0.6 4.6 1.1 1.7 0.6 3.4 0.4 50 11 89 255 10.1 0 10.3 10.1 09/20/2005 19:20:00 2.5 0.4 3.8 1.5 2.4 0.5 3.8 1.1 1.6 0.4 2.6 0.7 52 10 63 255 9.8 0.1 10.1 9.6 09/20/2005 19:30:00 2.8 0.5 4.2 1.9 2.7 0.5 3.8 1.5 1.8 0.5 3 0.7 52 13 38 255 9.6 0 9.8 9.6 09/20/2005 19:40:00 2.5 0.6 4.2 1.1 2.4 0.6 3.8 1.1 1.6 0.6 3 0.4 60 11 81 255 9.8 0 9.8 9.6 09/20/2005 19:50:00 2.3 0.4 3.4 1.5 2.1 0.4 3.4 1.1 1.3 0.5 2.6 0.4 63 10 42 255 9.1 0.1 9.6 8.8 09/20/2005 20:00:00 2.1 0.3 3 1.5 1.9 0.4 3 0.7 1.2 0.4 2.6 0.4 66 10 71 255 8.5 0.1 9 8.3 09/20/2005 20:10:00 2.6 0.4 3.8 1.5 2.4 0.4 3.8 1.5 1.6 0.4 3 0.7 69 9 78 255 8.2 0 8.5 8 09/20/2005 20:20:00 2.3 0.5 3.4 0.7 2 0.6 3.4 0.4 1.2 0.6 3 0.4 69 11 40 255 7.9 0 8.3 7.8 09/20/2005 20:30:00 1.6 0.4 2.6 0.4 1.3 0.4 2.3 0.4 0.6 0.4 1.9 0.4 82 13 56 255 7.6 0 7.8 7.5 09/20/2005 20:40:00 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.7 0.3 1.5 0.4 67 6 68 255 7.6 0 7.8 7.5 09/20/2005 20:50:00 2.2 0.5 3.4 1.1 2 0.5 3 0.7 1.2 0.5 2.3 0.4 72 9 69 255 7.4 0 7.5 7.3 09/20/2005 21:00:00 2.6 0.4 3.8 1.5 2.4 0.5 3.8 1.1 1.4 0.6 3 0.4 67 10 57 255 7.4 0 7.5 7.3 09/20/2005 21:10:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.5 0.5 2.6 0.4 70 11 55 255 7.4 0 7.5 7.3 09/20/2005 21:20:00 2.6 0.4 3.8 1.9 2.4 0.4 3.8 1.5 1.5 0.5 2.6 0.4 73 9 77 255 7.3 0 7.3 7.3 09/20/2005 21:30:00 2.4 0.4 3.4 1.5 2.2 0.4 3.4 0.7 1.1 0.5 2.6 0.4 83 12 88 255 7.2 0 7.3 7.3 09/20/2005 21:40:00 2.4 0.4 3.4 1.1 2.2 0.4 3.4 0.7 1.3 0.5 2.6 0.4 81 11 71 255 7.7 0.3 8.3 7.3 09/20/2005 21:50:00 2.7 0.4 4.2 1.9 2.4 0.5 4.2 1.1 1.7 0.5 3.4 0.4 90 11 77 255 8.3 0 8.5 8.3 09/20/2005 22:00:00 2.4 0.5 3.8 1.1 2.1 0.5 3.4 0.7 1.5 0.6 2.6 0.4 105 17 101 255 8.7 0 9 8.5 09/20/2005 22:10:00 2.8 0.4 3.8 1.9 2.5 0.4 3.4 1.1 1.7 0.5 3.4 0.4 100 11 101 255 8.8 0 9 8.8 09/20/2005 22:20:00 2.6 0.4 3.8 1.1 2.3 0.5 3.4 0.7 1.6 0.5 2.6 0.4 97 11 118 255 8.6 0.1 8.8 8.5 09/20/2005 22:30:00 2.2 0.2 2.6 1.5 1.9 0.3 2.6 1.1 1.2 0.4 1.9 0.4 94 10 111 255 8.3 0 8.5 8 09/20/2005 22:40:00 2.1 0.4 3 1.1 1.7 0.5 2.6 0.7 0.9 0.5 2.3 0.4 103 12 106 255 7.7 0.1 8 7.5 09/20/2005 22:50:00 2.2 0.4 3.4 1.1 1.9 0.5 3 0.7 0.7 0.3 1.5 0.4 99 13 80 255 7.4 0 7.5 7.3 09/20/2005 23:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 135 11 118 255 7.3 0 7.5 7.3 09/20/2005 23:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 190 39 255 255 7.1 0 7.3 7 09/20/2005 23:20:00 1.1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 75 36 42 255 6.7 0 7 6.5 09/20/2005 23:30:00 1.8 0.5 2.6 0.7 1.5 0.5 2.6 0.4 0.6 0.3 1.1 0.4 101 15 104 255 6.4 0.1 6.7 6.2 09/20/2005 23:40:00 2.5 0.4 3.4 1.9 2.2 0.4 3.4 1.1 1.3 0.5 2.6 0.4 76 20 43 255 6.2 0 6.2 6 09/20/2005 23:50:00 2.8 0.3 3.8 1.9 2.6 0.4 3.4 1.5 1.7 0.5 3 0.4 48 6 44 255 6 0 6.2 6 09/21/2005 00:00:00 2.1 0.5 3 1.1 1.8 0.6 3 0.7 1 0.5 2.3 0.4 64 9 53 255 5.7 0 6 5.5 09/21/2005 00:10:00 1.3 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 77 12 85 255 5.6 0 6 5.5 09/21/2005 00:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 90 0 89 255 5.7 0 5.7 5.7 09/21/2005 00:30:00 1.6 0.5 2.3 0.4 1.2 0.5 1.9 0.4 0.7 0.4 1.5 0.4 90 0 90 255 5.7 0 5.7 5.5 09/21/2005 00:40:00 2.4 0.4 3.4 1.5 2.1 0.4 3 1.1 1.3 0.4 2.6 0.4 107 9 121 255 5.4 0.1 5.7 5.2 09/21/2005 00:50:00 2.4 0.5 3.4 1.1 2.2 0.5 3 0.4 1.3 0.5 2.3 0.4 107 9 107 255 5.3 0 5.5 5.2 09/21/2005 01:00:00 2.4 0.3 3.4 1.5 2.2 0.4 3.4 1.1 1.4 0.4 2.3 0.4 95 8 84 255 5.6 0.2 5.7 5.2 09/21/2005 01:10:00 2.3 0.5 3.4 1.1 2 0.6 3.4 0.4 1.7 0.7 3.4 0.4 127 15 127 255 5.9 0.1 6.2 5.7 09/21/2005 01:20:00 2.1 0.5 3.4 1.1 1.8 0.5 3.4 0.4 1.3 0.6 3 0.4 125 15 158 255 6.5 0 6.7 6.2 09/21/2005 01:30:00 2.5 0.5 3.8 1.5 2.2 0.5 3.8 1.1 1.3 0.5 3 0.4 119 13 112 255 6.4 0.1 6.7 6.2 09/21/2005 01:40:00 2.6 0.5 3.8 1.1 2.4 0.5 3.4 0.7 1.3 0.6 3 0.4 113 14 111 255 6.2 0 6.2 6.2 09/21/2005 01:50:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.5 1.7 0.5 3 0.4 100 9 93 255 6.3 0 6.7 6.2 09/21/2005 02:00:00 2 0.4 3 1.1 1.7 0.5 3.4 0.7 0.5 0.3 1.9 0.4 97 11 93 255 6.6 0 6.7 6.5 09/21/2005 02:10:00 1.8 0.4 2.6 0.7 1.4 0.4 2.3 0.4 0.6 0.4 1.9 0.4 110 14 129 255 6.6 0 6.7 6.5 09/21/2005 02:20:00 2.4 0.4 3 0.7 2.1 0.4 3 0.4 1.1 0.5 2.3 0.4 111 9 109 255 6.7 0 6.7 6.7 09/21/2005 02:30:00 2.3 0.4 3.4 1.1 2 0.5 3 0.7 1.3 0.4 2.3 0.4 118 11 106 255 6.7 0 7 6.7 09/21/2005 02:40:00 2.6 0.5 3.8 1.5 2.3 0.6 3.4 1.1 1.6 0.6 3 0.4 119 15 158 255 7.1 0 7.3 6.7 09/21/2005 02:50:00 2.3 0.6 3.8 0.7 2 0.7 3.4 0.4 1.2 0.6 3 0.4 117 13 111 255 7.3 0 7.3 7.3 09/21/2005 03:00:00 2.5 0.4 3.8 1.5 2.2 0.4 3.4 1.1 1.2 0.5 3 0.4 112 12 102 255 7.3 0 7.3 7.3 09/21/2005 03:10:00 2.3 0.5 3.4 1.1 2 0.6 3.4 0.4 1.1 0.6 2.6 0.4 114 9 113 255 6.9 0.1 7.3 6.7 09/21/2005 03:20:00 2.3 0.4 3 1.5 2 0.4 3 1.1 0.9 0.4 1.9 0.4 110 8 102 255 6.2 0 6.7 6.2 09/21/2005 03:30:00 2.4 0.4 3.4 1.5 2.1 0.4 3 1.1 1.2 0.4 2.3 0.4 111 8 98 255 6.1 0 6.2 6 09/21/2005 03:40:00 2.5 0.5 3.8 1.5 2.3 0.5 3.4 1.1 1.5 0.6 2.6 0.4 112 8 113 255 5.7 0.1 6.2 5.7 09/21/2005 03:50:00 2.3 0.5 3.4 1.1 2 0.6 3.4 0.7 1 0.6 2.6 0.4 100 12 106 255 5.4 0 5.7 5.2 09/21/2005 04:00:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 75 14 80 255 5.2 0 5.7 5 09/21/2005 04:10:00 2.6 0.3 3.4 1.5 2.4 0.4 3.4 1.5 1.3 0.4 2.6 0.4 95 7 96 255 5.1 0 5.7 5 09/21/2005 04:20:00 2.9 0.5 4.2 1.5 2.7 0.5 3.8 1.1 1.6 0.6 2.6 0.4 102 9 97 255 4.9 0 5.2 4.8 09/21/2005 04:30:00 3 0.3 3.8 1.9 2.8 0.4 3.8 1.5 1.9 0.5 3 0.7 105 8 86 255 5.2 0.1 5.7 5 09/21/2005 04:40:00 3 0.4 3.8 1.9 2.8 0.4 3.8 1.5 1.9 0.5 3 0.7 110 9 108 255 5.2 0 5.7 5 09/21/2005 04:50:00 3.3 0.4 4.2 1.9 3.2 0.4 4.2 1.9 2 0.6 3.4 0.4 107 9 102 255 5.2 0 5.5 5 09/21/2005 05:00:00 3.1 0.5 4.2 1.5 2.9 0.5 4.2 1.5 1.9 0.6 3.4 0.4 111 12 110 255 5.1 0 5.5 5 09/21/2005 05:10:00 2.9 0.6 4.2 1.1 2.6 0.6 4.2 0.4 1.6 0.6 3 0.4 113 11 98 255 5.1 0 5 5 09/21/2005 05:20:00 2.2 0.5 3.4 0.4 1.8 0.6 3 0.4 0.6 0.4 1.9 0.4 115 13 112 255 4.9 0 5 4.8 09/21/2005 05:30:00 1.9 0.5 3 0.7 1.6 0.5 3 0.4 0.7 0.4 1.5 0.4 118 11 136 255 4.8 0.1 5 4.8 09/21/2005 05:40:00 2.1 0.6 3.4 0.7 1.8 0.6 3.4 0.4 1 0.5 3 0.4 118 9 130 255 4.6 0 4.8 4.5 09/21/2005 05:50:00 2.5 0.4 3.4 1.5 2.2 0.5 3.8 0.7 1.1 0.5 2.3 0.4 110 13 122 255 4.5 0 4.8 4.5 09/21/2005 06:00:00 2.7 0.4 3.4 1.5 2.5 0.4 3.4 0.7 1.3 0.5 2.6 0.4 111 9 99 255 4.4 0 4.5 4.3 09/21/2005 06:10:00 2.6 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.5 0.4 2.3 0.4 113 9 116 255 4.3 0 4.5 4.3 09/21/2005 06:20:00 2.8 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.5 0.4 2.6 0.4 108 8 94 255 4.2 0 4.5 4.3 09/21/2005 06:30:00 2.6 0.4 3.8 1.5 2.4 0.4 3.4 1.5 1.5 0.5 2.6 0.4 113 9 111 255 4.3 0 4.5 4.3 09/21/2005 06:40:00 2.7 0.5 3.8 1.1 2.4 0.5 3.8 0.7 1.5 0.5 2.6 0.4 112 9 126 255 4.2 0 4.5 4 09/21/2005 06:50:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.2 0.5 2.6 0.4 113 9 105 255 4 0 4.3 4 09/21/2005 07:00:00 2.2 0.5 3.4 1.1 1.9 0.5 3 0.7 1.1 0.4 2.3 0.4 118 10 119 255 4.1 0.1 4.8 4 09/21/2005 07:10:00 1.7 0.5 3 0.4 1.2 0.6 2.6 0.4 0.9 0.5 1.9 0.4 125 10 127 255 4.1 0.1 4.8 4 09/21/2005 07:20:00 1.7 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.8 0.4 1.9 0.4 121 8 95 255 4.2 0.1 4.8 4 09/21/2005 07:30:00 1.8 0.5 3 0.7 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 122 9 116 255 4.2 0 4.8 4 09/21/2005 07:40:00 2.8 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.6 0.5 3 0.4 111 9 110 255 4.5 0.3 5.2 4 09/21/2005 07:50:00 2.8 0.3 3.4 1.9 2.6 0.4 3.4 1.5 2 0.4 3 0.7 99 11 96 255 5.2 0.1 5.7 5 09/21/2005 08:00:00 2.8 0.6 4.2 1.1 2.6 0.6 3.8 1.1 1.9 0.6 3.4 0.7 109 14 107 255 6.2 0.3 7 5.5 09/21/2005 08:10:00 2.1 0.7 3.8 0.4 1.8 0.8 3.4 0.4 1.3 0.6 3 0.4 118 19 125 255 6.8 0.1 7.3 6.7 09/21/2005 08:20:00 1.8 0.6 3.4 0.4 1.5 0.6 3.4 0.4 1.1 0.5 2.3 0.4 102 28 125 255 8 0.5 9 7.3 09/21/2005 08:30:00 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 69 10 46 255 9.4 0.2 9.8 9 09/21/2005 08:40:00 1.4 0.7 3.4 0.4 1.1 0.7 3 0.4 1 0.6 2.3 0.4 85 17 108 255 10.1 0.1 10.3 9.8 09/21/2005 08:50:00 2 0.6 3 0.4 1.7 0.6 3 0.4 1.5 0.6 3 0.4 88 18 108 255 10.2 0 10.6 10.1 09/21/2005 09:00:00 2.2 0.7 3.8 1.1 1.9 0.8 3.4 0.4 1.6 0.8 3.4 0.4 71 17 85 255 10.4 0.3 10.9 10.1 09/21/2005 09:10:00 2 0.8 3.8 0.4 1.8 0.8 3.4 0.4 1.5 0.7 3.4 0.4 59 23 38 255 11.1 0 11.4 10.9 09/21/2005 09:20:00 2.5 0.4 3.4 1.1 2.3 0.4 3.4 1.1 2.1 0.5 3 0.7 33 12 63 255 11.5 0.2 11.7 11.1 09/21/2005 09:30:00 2.2 0.4 3.4 1.5 2 0.5 3 0.7 1.6 0.6 3 0.4 23 22 44 255 11.8 0 12.2 11.7 09/21/2005 09:40:00 2 0.5 3.4 0.4 1.9 0.5 3.4 0.4 1.5 0.5 3 0.4 16 17 353 255 12.7 0.2 12.7 12.2 09/21/2005 09:50:00 1.9 0.4 3 0.7 1.9 0.4 3 1.1 1.6 0.6 2.6 0.4 18 10 5 255 12.7 0 13 12.5 09/21/2005 10:00:00 2 0.4 3 0.7 1.8 0.5 3 0.4 1.5 0.5 3 0.4 4 17 5 255 13 0 13.3 12.7 09/21/2005 10:10:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 16 22 9 255 13.5 0 13.8 13.3 09/21/2005 10:20:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 23 18 2 255 13.1 0 13.5 13 09/21/2005 10:30:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.3 1.9 0.4 269 94 211 255 13.3 0 13.8 13 09/21/2005 10:40:00 1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.7 0.5 2.3 0.4 318 18 321 255 13.2 0.2 13.8 12.7 09/21/2005 10:50:00 1.3 0.6 3 0.4 1.2 0.6 3 0.4 0.8 0.5 2.3 0.4 315 47 309 255 12.9 0 13.3 12.7 09/21/2005 11:00:00 1.3 0.7 3.4 0.4 1.2 0.7 3.4 0.4 1 0.7 3 0.4 270 35 266 255 13.3 0 13.5 13 09/21/2005 11:10:00 2.1 0.9 4.2 0.4 1.9 0.9 4.2 0.4 1.7 1 4.2 0.4 295 35 253 255 13.1 0 13.5 13 09/21/2005 11:20:00 2.3 0.7 4.2 0.4 2.1 0.7 4.2 0.4 1.7 0.8 3.8 0.4 311 33 335 255 13.3 0.1 14.1 13 09/21/2005 11:30:00 3.3 1.1 5.7 0.4 3.2 1.1 5.7 0.4 2.6 1.1 4.9 0.4 303 20 290 255 13.7 0 14.4 13.5 09/21/2005 11:40:00 2.6 1.2 5.3 0.4 2.4 1.2 5.7 0.4 1.9 1 4.2 0.4 299 33 0 255 14.3 0.4 15.2 13.8 09/21/2005 11:50:00 2.6 0.8 4.2 0.7 2.5 0.9 4.2 0.4 2.1 1 4.2 0.4 282 29 266 255 14.3 0.1 15.2 13.8 09/21/2005 12:00:00 2.3 0.9 4.9 0.4 2.2 0.9 4.6 0.4 2 0.8 4.2 0.4 290 29 300 255 13.9 0 14.4 13.8 09/21/2005 12:10:00 2.6 1 4.6 0.4 2.5 1 4.9 0.4 1.9 1.1 4.2 0.4 294 41 314 255 13.9 0 14.4 13.8 09/21/2005 12:20:00 2.9 0.8 4.9 0.4 2.7 0.8 4.6 0.4 2.2 0.9 4.2 0.4 310 19 333 255 14.4 0.1 14.9 13.8 09/21/2005 12:30:00 1.8 0.9 4.6 0.4 1.8 0.8 4.6 0.4 1.4 0.9 3.8 0.4 238 38 298 255 15.2 0.2 15.7 14.9 09/21/2005 12:40:00 2.6 0.9 5.3 0.4 2.6 0.9 5.3 0.4 2.3 1 5.3 0.4 283 27 258 255 15.3 0.3 16.3 14.9 09/21/2005 12:50:00 3 1.2 6.1 0.4 3 1.1 6.1 0.4 2.5 1.1 5.3 0.4 301 26 346 255 14.8 0.2 15.5 14.4 09/21/2005 13:00:00 2.1 1 4.6 0.4 2.1 1 4.9 0.4 2 1.1 4.9 0.4 275 27 238 255 14.6 0 15.2 14.4 09/21/2005 13:10:00 2.9 0.7 4.2 1.1 2.8 0.6 4.6 1.1 2.6 0.7 4.2 0.7 281 24 301 255 14.6 0.1 15.2 14.4 09/21/2005 13:20:00 2.9 0.7 4.6 0.4 2.8 0.8 4.6 0.4 2.4 0.8 4.9 0.4 292 23 28 255 14.8 0.1 15.2 14.6 09/21/2005 13:30:00 2.5 0.5 4.2 0.7 2.5 0.6 4.2 0.7 2.1 0.6 3.8 0.4 280 21 269 255 14.4 0 15.2 14.4 09/21/2005 13:40:00 2.7 0.7 4.2 0.7 2.6 0.8 4.2 0.4 2.1 0.9 4.2 0.4 296 20 313 255 15 0.4 16 14.6 09/21/2005 13:50:00 2.4 1 4.6 0.4 2.4 1 4.9 0.4 1.9 0.9 3.8 0.4 282 43 253 255 15.4 0.2 16 15.2 09/21/2005 14:00:00 2.8 0.6 4.6 1.1 2.6 0.7 4.6 0.4 2.4 0.7 3.8 0.4 266 17 270 255 15 0 15.7 14.9 09/21/2005 14:10:00 1.7 0.8 3.8 0.4 1.6 0.8 3.4 0.4 1.3 0.7 3 0.4 266 45 314 255 15 0 15.5 14.9 09/21/2005 14:20:00 1.8 0.7 3 0.4 1.6 0.6 3.4 0.4 1.1 0.7 3 0.4 283 22 280 255 14.9 0 15.5 14.6 09/21/2005 14:30:00 2.1 1.3 4.9 0.4 1.9 1.2 4.9 0.4 1.7 1.3 5.7 0.4 281 28 299 255 14.8 0 15.5 14.4 09/21/2005 14:40:00 2.9 0.9 4.9 0.4 2.8 0.8 4.6 0.7 2.2 0.9 4.6 0.4 291 20 290 255 14.3 0.1 14.9 14.1 09/21/2005 14:50:00 2.3 0.9 4.6 0.4 2.1 1 4.6 0.4 1.5 1 4.6 0.4 285 26 256 255 14.2 0.1 14.9 13.8 09/21/2005 15:00:00 1.7 0.8 4.2 0.4 1.6 0.9 3.8 0.4 1.2 0.7 3.4 0.4 280 29 261 255 14 0.1 14.6 13.8 09/21/2005 15:10:00 2.3 1.1 4.9 0.4 2.1 1.2 4.6 0.4 1.7 1.2 5.3 0.4 285 23 272 255 14.3 0 14.9 13.8 09/21/2005 15:20:00 2.4 0.9 4.6 0.4 2.3 0.8 4.6 0.7 1.9 0.8 4.2 0.4 278 30 262 255 14.4 0 14.9 14.4 09/21/2005 15:30:00 3.2 0.8 4.9 1.5 2.9 0.8 5.3 0.7 2.5 1 5.3 0.7 289 21 293 255 14.4 0 14.6 14.1 09/21/2005 15:40:00 3.5 0.7 5.3 1.5 3.3 0.8 5.3 1.5 2.9 0.9 4.9 1.1 282 17 280 255 14 0 14.6 13.8 09/21/2005 15:50:00 3.3 1 5.7 0.7 3.2 1 5.7 0.7 2.5 1.2 5.3 0.4 286 24 266 255 14 0 14.6 13.8 09/21/2005 16:00:00 3.1 0.9 5.7 1.5 2.9 0.9 5.3 1.1 2.4 1 4.6 0.4 285 21 287 255 13.7 0.1 14.1 13.5 09/21/2005 16:10:00 2.8 1 5.3 0.7 2.7 1 5.3 0.7 2.2 0.9 4.9 0.4 276 21 280 255 13.4 0 13.8 13.3 09/21/2005 16:20:00 2.6 1.1 5.7 0.4 2.5 1.1 5.7 0.4 2.1 1.1 5.7 0.4 270 20 269 255 13.3 0 13.8 13 09/21/2005 16:30:00 2.3 1.1 4.6 0.4 2.2 1.1 4.6 0.4 1.7 1 3.8 0.4 271 24 300 255 13.1 0 13.5 13 09/21/2005 16:40:00 2.4 1 5.3 0.4 2.3 1 5.3 0.4 1.5 0.8 3.8 0.4 262 28 255 255 13.1 0 13.3 13 09/21/2005 16:50:00 2.4 1 4.6 0.4 2.4 1.1 4.6 0.4 1.6 1 4.6 0.4 276 22 278 255 13 0.1 13.5 12.7 09/21/2005 17:00:00 2.1 1 4.6 0.4 2 1 4.6 0.4 1.5 0.8 4.6 0.4 263 19 245 255 12.8 0 13 12.7 09/21/2005 17:10:00 1.6 0.8 3.8 0.4 1.5 0.7 3.8 0.4 0.8 0.6 2.3 0.4 252 17 249 255 12.7 0 12.7 12.5 09/21/2005 17:20:00 1.6 0.7 3 0.4 1.5 0.6 3 0.4 0.9 0.5 2.3 0.4 263 21 253 255 12.5 0 12.7 12.5 09/21/2005 17:30:00 1.1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 245 11 259 255 12.4 0 12.7 12.2 09/21/2005 17:40:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.6 0.4 1.5 0.4 246 8 250 255 12.3 0 12.5 12.2 09/21/2005 17:50:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 238 10 239 255 12.1 0 12.2 11.9 09/21/2005 18:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 251 0 251 255 11.8 0 12.2 11.7 09/21/2005 18:10:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 251 0 251 255 11.5 0 11.7 11.4 09/21/2005 18:20:00 1.2 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 248 7 251 255 11.2 0 11.4 10.9 09/21/2005 18:30:00 2.1 0.5 3.4 1.1 1.9 0.5 3 0.7 1 0.5 2.6 0.4 206 13 209 255 10.7 0 11.1 10.6 09/21/2005 18:40:00 2 0.6 3.4 0.7 1.9 0.5 3 0.7 1 0.5 2.3 0.4 191 11 202 255 10.3 0.1 10.6 10.3 09/21/2005 18:50:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.4 0.7 0.3 1.5 0.4 182 4 184 255 10.1 0 10.3 9.8 09/21/2005 19:00:00 1.4 0.4 2.3 0.4 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 185 4 185 255 9.9 0 10.1 9.8 09/21/2005 19:10:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 165 4 165 255 9.7 0 9.8 9.6 09/21/2005 19:20:00 0.9 0.7 2.3 0.4 0.8 0.6 2.3 0.4 0.5 0.3 1.9 0.4 156 10 143 255 9.6 0 9.8 9.6 09/21/2005 19:30:00 1.9 0.4 2.6 1.1 2 0.2 2.6 1.1 1.3 0.3 1.9 0.4 168 11 158 255 9.5 0 9.6 9.6 09/21/2005 19:40:00 2.3 0.7 3.4 0.4 2.1 0.8 3.4 0.4 1.5 0.8 3 0.4 136 11 140 255 9.5 0 9.6 9.6 09/21/2005 19:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 215 33 233 255 9.6 0 9.8 9.6 09/21/2005 20:00:00 1.7 0.4 2.3 1.1 1.4 0.4 2.3 0.4 1.2 0.5 1.9 0.4 155 9 152 255 9.5 0 9.6 9.6 09/21/2005 20:10:00 1.3 0.6 2.3 0.4 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 165 13 155 255 9.5 0 9.6 9.3 09/21/2005 20:20:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 163 11 156 255 9.5 0 9.6 9.3 09/21/2005 20:30:00 1.1 0.3 1.5 0.4 0.8 0.2 1.1 0.4 0.4 0.1 0.7 0.4 156 0 156 255 9.4 0 9.6 9.3 09/21/2005 20:40:00 0.7 0.3 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 156 0 157 255 9.4 0 9.6 9.3 09/21/2005 20:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 157 255 9.2 0 9.3 9.3 09/21/2005 21:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 217 53 269 255 9.2 0 9.3 9 09/21/2005 21:10:00 1.1 0.7 2.3 0.4 0.8 0.7 2.3 0.4 0.7 0.5 1.9 0.4 247 12 259 255 9.2 0 9.3 9 09/21/2005 21:20:00 1.6 0.3 2.3 1.1 1.3 0.3 2.3 0.7 0.6 0.3 1.5 0.4 256 2 260 255 9.1 0 9.3 9 09/21/2005 21:30:00 0.9 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 253 0 253 255 9.1 0 9.3 9 09/21/2005 21:40:00 0.8 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.5 0.4 274 43 253 255 9 0 9 9 09/21/2005 21:50:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.5 0.4 261 33 247 255 9 0 9 9 09/21/2005 22:00:00 1 0.6 2.6 0.4 0.7 0.6 2.3 0.4 0.5 0.3 1.5 0.4 249 18 228 255 9 0 9 9 09/21/2005 22:10:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 249 33 270 255 9 0 9 9 09/21/2005 22:20:00 1.5 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.4 0.2 1.5 0.4 241 11 233 255 9 0 9.3 9 09/21/2005 22:30:00 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 0.6 0.4 1.9 0.4 217 13 225 255 9 0 9 9 09/21/2005 22:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 210 12 234 255 8.9 0 9 9 09/21/2005 22:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 240 0 240 255 8.9 0 9 9 09/21/2005 23:00:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 295 16 311 255 8.9 0 9 9 09/21/2005 23:10:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 311 0 311 255 8.9 0 9 8.8 09/21/2005 23:20:00 1 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 314 12 332 255 8.9 0 9 8.8 09/21/2005 23:30:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 5 27 17 255 8.9 0 9 9 09/21/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 8.9 0 9 8.8 09/21/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 255 255 8.9 0 9 8.8 09/22/2005 00:00:00 0.9 0.6 2.6 0.4 0.7 0.5 1.9 0.4 0.5 0.4 2.3 0.4 27 10 21 255 8.9 0 9 8.8 09/22/2005 00:10:00 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.9 0.4 60 61 42 255 8.9 0 9 9 09/22/2005 00:20:00 1.8 0.8 3.8 0.4 1.5 0.8 3.4 0.4 1.3 0.6 3 0.4 88 72 8 255 9 0 9 9 09/22/2005 00:30:00 1.5 0.7 2.6 0.4 1.3 0.7 2.3 0.4 1 0.7 2.3 0.4 89 27 71 255 8.9 0 9 9 09/22/2005 00:40:00 1.8 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1 0.6 2.6 0.4 101 14 115 255 8.9 0 9 9 09/22/2005 00:50:00 1.9 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1.2 0.5 2.3 0.4 99 10 96 255 8.9 0 9 8.8 09/22/2005 01:00:00 1.8 0.4 3 0.7 1.5 0.5 2.6 0.4 1.1 0.6 2.3 0.4 102 17 99 255 8.9 0 9 8.8 09/22/2005 01:10:00 2.4 0.5 3.4 1.1 2.1 0.5 3 0.7 1.7 0.5 3 0.4 103 12 109 255 8.9 0 9 8.8 09/22/2005 01:20:00 2.3 0.6 3.8 0.4 2 0.7 3.4 0.4 1.5 0.7 3 0.4 112 13 104 255 8.9 0 9 8.8 09/22/2005 01:30:00 2.7 0.7 5.3 0.7 2.5 0.6 4.9 0.7 2.1 0.6 4.2 0.7 117 20 58 255 8.9 0 9 8.8 09/22/2005 01:40:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.8 3.4 0.4 97 24 113 255 9 0 9 9 09/22/2005 01:50:00 2.9 0.5 4.2 0.7 2.7 0.6 3.8 0.7 2.2 0.6 3.8 0.7 97 21 115 255 9 0 9 9 09/22/2005 02:00:00 2.3 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1.6 0.6 2.6 0.4 90 15 91 255 8.9 0 9 9 09/22/2005 02:10:00 2.2 0.6 3.4 0.4 2 0.7 3.4 0.4 1.5 0.7 3 0.4 74 13 62 255 8.9 0 9 8.8 09/22/2005 02:20:00 3.2 0.6 4.6 1.9 3 0.6 4.6 1.5 2.4 0.7 4.6 0.4 67 11 66 255 8.8 0 9 8.8 09/22/2005 02:30:00 3.3 0.6 5.3 1.9 3.1 0.6 5.3 1.9 2.4 0.6 3.8 1.1 79 11 68 255 8.7 0 8.8 8.5 09/22/2005 02:40:00 3.7 0.6 5.3 2.3 3.5 0.6 5.3 1.9 2.7 0.7 4.6 0.7 70 11 64 255 8.7 0 8.8 8.5 09/22/2005 02:50:00 3.3 0.8 5.3 1.5 3.2 0.8 5.3 1.1 2.2 1 4.9 0.4 72 15 62 255 8.7 0 8.8 8.8 09/22/2005 03:00:00 2.5 0.8 4.9 0.7 2.3 0.8 4.9 0.4 1.6 0.7 3.4 0.4 90 13 61 255 8.7 0 8.8 8.5 09/22/2005 03:10:00 2.7 0.7 4.2 0.7 2.5 0.7 4.2 0.7 1.8 0.6 3.4 0.4 85 14 91 255 8.6 0 8.8 8.5 09/22/2005 03:20:00 2.5 0.4 3.8 1.5 2.3 0.5 3.4 1.1 1.5 0.5 2.6 0.4 104 14 106 255 8.5 0 8.8 8.5 09/22/2005 03:30:00 2.9 0.6 4.2 1.5 2.7 0.6 4.2 0.7 1.9 0.6 3.4 0.4 113 11 118 255 8.6 0 8.8 8.5 09/22/2005 03:40:00 3.4 0.6 4.6 1.5 3.2 0.6 4.9 1.5 2.1 0.6 3.8 0.7 107 13 94 255 8.7 0 8.8 8.8 09/22/2005 03:50:00 2.7 0.7 4.6 1.1 2.5 0.8 4.6 0.7 1.8 0.7 3.8 0.4 109 16 93 255 8.8 0 9 8.8 09/22/2005 04:00:00 3.5 0.7 5.3 1.9 3.3 0.8 5.3 1.5 2.6 0.8 4.9 0.4 116 14 112 255 8.9 0 9 8.8 09/22/2005 04:10:00 3.2 0.6 4.6 1.5 2.9 0.7 4.9 1.1 2.2 0.7 4.2 0.7 122 15 94 255 8.9 0 9 9 09/22/2005 04:20:00 3.2 0.6 4.9 1.5 3 0.6 4.6 1.5 2.2 0.6 3.8 0.4 110 15 97 255 8.9 0 9 8.8 09/22/2005 04:30:00 3.8 0.6 5.3 2.3 3.6 0.6 4.9 1.9 2.7 0.6 4.2 1.1 104 10 94 255 8.9 0 9 8.8 09/22/2005 04:40:00 3.8 0.6 5.3 2.3 3.7 0.6 5.3 1.9 2.7 0.8 4.6 0.4 108 12 113 255 8.9 0 9 8.8 09/22/2005 04:50:00 4.2 0.6 5.3 3 4 0.6 5.3 2.3 3.1 0.7 4.9 1.1 111 11 109 255 8.9 0 9 8.8 09/22/2005 05:00:00 3.6 0.7 5.3 1.5 3.4 0.7 4.9 1.1 2.6 0.7 4.6 0.7 117 15 109 255 8.9 0 9 8.8 09/22/2005 05:10:00 3.4 0.5 4.9 1.9 3.2 0.5 4.9 1.9 2.6 0.6 4.9 1.1 104 12 96 255 8.9 0 9 8.8 09/22/2005 05:20:00 4.1 0.8 6.1 2.3 3.9 0.8 5.7 1.9 3 1 5.3 1.1 100 12 102 255 8.9 0 9 8.8 09/22/2005 05:30:00 3.6 0.6 4.9 1.9 3.5 0.6 4.9 1.9 2.7 0.7 4.6 1.1 103 12 100 255 8.9 0 9 8.8 09/22/2005 05:40:00 3.4 0.8 5.7 1.5 3.2 0.8 6.1 1.5 2.4 0.7 4.9 0.7 115 15 117 255 8.9 0 9 8.8 09/22/2005 05:50:00 3.7 0.7 5.3 1.5 3.6 0.7 5.3 1.9 2.8 0.8 4.6 0.7 108 11 105 255 8.9 0 9 8.8 09/22/2005 06:00:00 3.8 0.7 5.3 2.3 3.6 0.7 5.3 1.9 2.9 0.6 4.6 1.5 106 14 90 255 8.9 0 9 8.8 09/22/2005 06:10:00 4 0.7 6.1 2.3 3.8 0.8 6.1 1.9 3 0.7 4.6 1.5 106 13 125 255 8.9 0 9 8.8 09/22/2005 06:20:00 4.1 0.9 6.5 1.9 4 0.9 6.5 1.5 3 0.9 5.3 0.7 109 15 112 255 8.9 0 9 8.8 09/22/2005 06:30:00 3.6 0.7 5.7 1.5 3.4 0.8 5.3 1.1 2.4 0.7 4.2 0.4 108 15 121 255 8.9 0 9 9 09/22/2005 06:40:00 4.3 0.7 6.1 1.9 4.2 0.7 5.7 1.9 3.3 0.8 4.9 1.5 98 10 83 255 9 0 9 9 09/22/2005 06:50:00 4.5 0.8 6.8 2.3 4.3 0.8 6.5 2.3 3.4 1 5.7 0.7 108 12 82 255 9 0 9 9 09/22/2005 07:00:00 4.2 0.8 6.5 1.5 4.1 0.8 6.1 1.5 3.2 0.9 5.7 0.7 107 14 108 255 9 0 9 9 09/22/2005 07:10:00 4.2 0.8 6.1 2.6 4.1 0.8 5.7 1.9 3.2 0.8 5.3 1.5 109 14 97 255 9 0 9 9 09/22/2005 07:20:00 4.3 0.7 6.1 2.6 4.2 0.7 6.1 2.3 3.2 0.8 5.3 1.1 106 12 97 255 9 0 9.3 9 09/22/2005 07:30:00 4.4 0.7 6.5 2.6 4.3 0.6 6.1 2.3 3.1 0.8 5.3 0.7 105 14 110 255 9.1 0 9.3 9 09/22/2005 07:40:00 4.2 0.8 6.8 2.3 4.1 0.9 6.5 1.9 3.1 1 5.3 0.7 109 15 101 255 9.2 0 9.3 9 09/22/2005 07:50:00 3.8 0.6 5.3 2.3 3.6 0.7 5.3 1.5 2.9 0.8 4.9 0.7 97 14 77 255 9.3 0 9.3 9.3 09/22/2005 08:00:00 3.8 0.8 5.7 1.5 3.7 0.8 5.7 1.1 2.8 0.8 5.3 0.7 105 15 108 255 9.4 0 9.6 9.3 09/22/2005 08:10:00 4.2 0.9 6.1 0.7 4 0.9 5.7 1.5 3.3 0.9 5.3 1.1 106 14 99 255 9.5 0 9.6 9.3 09/22/2005 08:20:00 4 0.9 6.1 1.9 3.8 0.8 5.7 1.5 3 0.9 4.9 1.1 108 15 104 255 9.4 0 9.6 9.3 09/22/2005 08:30:00 3.7 0.8 6.1 1.9 3.6 0.9 6.1 1.5 2.6 0.8 5.7 0.7 111 17 115 255 9.5 0 9.6 9.6 09/22/2005 08:40:00 4.2 0.7 6.1 2.6 4.1 0.7 6.5 1.9 3.3 0.8 5.3 1.5 94 12 99 255 9.8 0.1 10.1 9.6 09/22/2005 08:50:00 3.3 0.9 5.3 1.5 3.1 1 5.3 1.1 2.5 1 5.3 0.7 106 18 74 255 10 0 10.1 10.1 09/22/2005 09:00:00 3.1 0.6 4.9 1.1 2.8 0.7 5.3 0.7 2.1 0.8 4.2 0.4 113 18 102 255 10 0 10.1 10.1 09/22/2005 09:10:00 3.1 0.6 4.9 1.1 2.9 0.6 4.9 1.1 2.4 0.7 4.6 0.7 115 17 137 255 10.1 0 10.3 10.1 09/22/2005 09:20:00 3.4 0.8 5.7 1.9 3.2 0.8 5.3 1.5 2.6 0.8 4.6 0.7 91 12 100 255 10.2 0 10.6 10.3 09/22/2005 09:30:00 3.4 0.6 5.3 1.9 3.3 0.6 4.9 1.9 2.6 0.7 4.2 0.7 96 16 101 255 10.5 0 10.6 10.3 09/22/2005 09:40:00 3.4 1 5.7 1.5 3.3 1 5.7 1.1 2.6 1 5.7 0.4 84 16 106 255 10.7 0 10.9 10.6 09/22/2005 09:50:00 3.2 1 6.5 0.7 3 1.1 6.1 0.4 2.5 1.1 5.3 0.4 92 20 97 255 11 0 11.1 10.9 09/22/2005 10:00:00 3.9 1.1 7.2 1.5 3.7 1.1 6.8 0.7 3.1 1 5.7 1.1 90 17 89 255 11.2 0 11.4 11.1 09/22/2005 10:10:00 3.9 0.9 6.1 1.5 3.7 0.9 6.1 1.5 3.1 1 5.3 0.4 84 15 74 255 11.5 0 11.7 11.4 09/22/2005 10:20:00 4.1 1.1 6.8 1.5 4 1.1 6.5 1.1 3.4 1.1 6.5 0.7 74 20 87 255 12.2 0.3 12.7 11.7 09/22/2005 10:30:00 4.3 1.3 8 1.5 4.3 1.3 8 1.1 3.5 1.4 6.8 0.7 71 20 49 255 12.5 0.1 12.7 12.2 09/22/2005 10:40:00 4 1.1 6.8 0.7 3.9 1.1 6.8 0.4 3.4 1.2 6.5 0.4 79 29 79 255 12.6 0 12.7 12.5 09/22/2005 10:50:00 4.3 1.2 8 1.9 4.2 1.3 7.6 1.1 3.3 1.1 6.1 0.4 74 22 94 255 12.7 0.1 13 12.5 09/22/2005 11:00:00 3.9 0.8 6.5 2.3 3.8 0.9 6.5 1.9 3.1 0.9 4.9 1.1 61 22 65 255 13.2 0 13.3 13 09/22/2005 11:10:00 4.1 1 6.5 1.5 3.9 1 6.1 1.5 3.5 1.1 6.5 0.4 80 19 80 255 13.3 0 13.5 13 09/22/2005 11:20:00 4.1 1.1 6.5 0.7 3.9 1.1 6.5 1.1 3.4 1.1 6.5 1.1 53 20 27 255 13.6 0 13.8 13.3 09/22/2005 11:30:00 4.5 1 6.8 1.9 4.4 1 6.8 1.5 3.5 1 6.1 1.1 77 22 88 255 13.8 0 13.8 13.5 09/22/2005 11:40:00 5.2 1.2 8.4 2.3 5.2 1.2 8.4 2.3 4.4 1.2 7.6 1.9 74 22 56 255 13.7 0 13.8 13.5 09/22/2005 11:50:00 4.7 1.1 8.4 2.6 4.7 1.1 8 2.3 3.9 1.1 7.6 1.1 75 23 81 255 14.1 0.1 14.6 13.8 09/22/2005 12:00:00 4.9 1.1 8.4 2.3 4.9 1.1 8 1.5 4.2 1.2 8 1.9 51 22 95 255 15 0.2 15.5 14.6 09/22/2005 12:10:00 5.7 2.1 11.1 2.3 5.6 2.2 11.1 2.3 4.7 1.9 10.3 2.3 52 21 40 255 15.3 0 15.7 15.2 09/22/2005 12:20:00 6.8 2.3 12.6 1.9 6.7 2.3 12.2 1.9 5.5 2.4 11.5 0.7 44 23 51 255 15 0 15.5 14.9 09/22/2005 12:30:00 6.7 1.7 13.3 3.4 6.6 1.7 12.6 3.4 5.2 1.5 10.3 2.6 23 19 10 255 15.2 0.1 15.7 15.2 09/22/2005 12:40:00 7.9 1.7 12.6 3.4 7.8 1.7 12.6 3 6.1 1.7 11.1 2.6 19 15 8 255 15 0 15.7 14.9 09/22/2005 12:50:00 8.6 1.7 14.1 3.8 8.5 1.7 13.7 4.2 6.7 1.9 12.2 1.9 24 15 358 255 14.7 0 15.2 14.6 09/22/2005 13:00:00 8.2 1.9 14.9 4.2 8.1 1.9 14.5 3.4 6.2 1.9 13 1.9 20 14 14 255 14.3 0 14.6 14.4 09/22/2005 13:10:00 7.8 1.5 11.5 4.2 7.8 1.5 11.8 3.8 6.3 1.5 11.5 2.6 24 14 29 255 14.2 0 14.6 14.1 09/22/2005 13:20:00 7.8 1.6 12.2 3.4 7.7 1.6 11.8 3 6.5 1.5 10.3 3 32 16 22 255 14.3 0 14.9 14.4 09/22/2005 13:30:00 8.7 1.7 13.3 4.2 8.6 1.7 13.3 4.6 7 1.9 13 3.4 25 14 32 255 14.4 0 14.9 14.4 09/22/2005 13:40:00 9.4 2 13.7 3.4 9.4 2.1 13.7 3.4 7.5 2.3 13 2.6 20 15 34 255 14.4 0 14.9 14.4 09/22/2005 13:50:00 10 2.4 15.3 4.6 9.9 2.5 16.1 4.6 8.4 2.6 14.5 3 24 13 29 255 14 0.1 14.6 13.8 09/22/2005 14:00:00 10.8 2.5 17.9 4.9 10.7 2.5 17.9 4.9 8.9 2.6 16.4 2.6 22 13 21 255 13.9 0 13.8 13.8 09/22/2005 14:10:00 8.6 1.7 13.3 4.6 8.5 1.7 13.3 4.2 6.4 1.8 10.7 2.3 11 15 339 255 13.7 0 13.8 13.5 09/22/2005 14:20:00 8.8 1.6 13.3 4.6 8.8 1.6 13.7 4.2 6.8 1.9 11.8 2.6 12 12 12 255 13.6 0 13.8 13.5 09/22/2005 14:30:00 8.7 1.8 14.1 4.2 8.6 1.9 14.1 4.2 6.5 1.9 11.5 2.6 13 13 355 255 13.7 0 13.8 13.5 09/22/2005 14:40:00 9.3 1.7 13.3 5.3 9.2 1.8 13 5.3 7.7 2.1 12.6 2.6 18 12 29 255 13.9 0 13.8 13.8 09/22/2005 14:50:00 8.2 1.7 13 4.6 8.2 1.7 12.6 4.2 6.3 2 12.2 1.9 14 15 4 255 13.7 0 13.8 13.5 09/22/2005 15:00:00 8 1.5 12.2 3.4 7.9 1.5 12.6 3 6.7 1.7 11.5 2.3 24 13 35 255 13.6 0 13.8 13.5 09/22/2005 15:10:00 8.4 1.8 12.6 4.2 8.4 1.8 12.6 3.8 6.8 2.1 11.8 2.6 23 15 19 255 13.5 0 13.5 13.3 09/22/2005 15:20:00 8 1.7 13.7 4.2 8 1.8 14.1 4.6 6.3 1.6 11.5 2.3 19 13 354 255 13.3 0 13.5 13.3 09/22/2005 15:30:00 8.4 1.7 12.6 4.6 8.4 1.7 12.6 4.6 7.1 1.7 13 3 25 12 23 255 13.3 0 13.3 13 09/22/2005 15:40:00 8.2 1.8 13 4.2 8.1 1.8 13 3.8 6.5 1.8 11.1 1.1 23 15 16 255 12.9 0.1 13.3 12.7 09/22/2005 15:50:00 9.7 2.1 14.1 4.6 9.7 2.2 14.5 4.6 8 2.3 14.1 2.6 16 14 27 255 12.5 0.1 12.7 12.2 09/22/2005 16:00:00 9 2 13.7 4.6 8.9 2 13.7 3.8 7.1 1.9 12.2 3 19 14 26 255 12.1 0 12.2 11.9 09/22/2005 16:10:00 8.7 2.5 14.5 3.4 8.6 2.6 14.5 3.4 6.6 2.8 13.3 1.5 13 17 14 255 12.3 0 12.5 12.2 09/22/2005 16:20:00 8.1 1.7 13.7 4.6 8 1.7 13.7 4.6 6.6 1.7 10.7 3 22 16 36 255 12.3 0 12.5 12.2 09/22/2005 16:30:00 9.5 2 15.3 5.3 9.5 2.1 14.9 5.3 7.7 1.9 12.6 3.8 21 12 28 255 12.3 0 12.5 11.9 09/22/2005 16:40:00 9.6 2.3 14.5 4.2 9.6 2.3 14.9 4.2 7.8 2.3 12.6 3 17 12 31 255 11.8 0.1 12.2 11.4 09/22/2005 16:50:00 9.6 1.8 14.5 5.3 9.6 1.7 14.1 5.3 7.8 2 13.3 3.4 17 12 20 255 11.4 0.1 11.7 11.1 09/22/2005 17:00:00 8.4 1.5 12.6 5.3 8.4 1.5 12.6 4.9 6.6 1.7 11.5 1.9 19 12 25 255 11.2 0 11.4 11.1 09/22/2005 17:10:00 8.1 1.8 13 4.2 8.1 1.7 13 4.2 6.4 1.7 11.1 1.9 21 15 16 255 11.1 0 11.1 10.9 09/22/2005 17:20:00 9.2 2.2 15.3 4.9 9.2 2.2 15.3 4.6 7.4 2.1 11.8 3 20 13 17 255 10.9 0 11.1 10.9 09/22/2005 17:30:00 9.1 1.9 14.1 4.9 9.1 2 14.5 4.9 7.3 1.7 13.3 3 23 14 4 255 11.1 0 11.4 10.9 09/22/2005 17:40:00 8.6 2.2 13.3 3.4 8.6 2.3 13.3 3.4 7.1 2.2 12.6 3 21 12 39 255 11.1 0 11.1 11.1 09/22/2005 17:50:00 7.4 1.5 11.8 4.6 7.3 1.5 11.8 4.6 5.8 1.6 10.7 2.3 21 14 28 255 10.9 0.1 11.1 10.6 09/22/2005 18:00:00 7.4 1.4 12.2 3.8 7.3 1.5 12.2 3.8 5.8 1.5 9.5 2.6 19 12 10 255 10.5 0 10.6 10.3 09/22/2005 18:10:00 7.7 1.5 12.6 4.9 7.6 1.6 12.6 4.6 6.2 1.7 11.8 2.6 19 13 19 255 10.3 0 10.6 10.1 09/22/2005 18:20:00 7.6 1.5 12.6 2.3 7.5 1.6 12.2 2.3 6.1 1.5 11.1 1.9 17 13 28 255 10.2 0 10.3 10.1 09/22/2005 18:30:00 7.6 1.3 10.7 4.6 7.6 1.3 10.7 4.6 5.8 1.5 10.3 1.5 18 13 37 255 10.1 0 10.3 9.8 09/22/2005 18:40:00 8.2 1.6 12.2 4.2 8.2 1.6 12.2 4.2 6.4 1.7 11.5 3 15 14 15 255 10 0 10.1 9.8 09/22/2005 18:50:00 8.4 2 14.1 4.2 8.4 2.1 14.5 3.4 6.5 2.2 13.7 2.3 15 13 16 255 9.9 0 10.1 9.8 09/22/2005 19:00:00 7.7 1.7 12.6 4.2 7.6 1.7 12.6 3.8 5.7 1.7 11.1 2.3 17 15 11 255 9.8 0 10.1 9.6 09/22/2005 19:10:00 7.6 1.5 13.7 4.2 7.5 1.6 13.7 4.2 6 1.7 12.2 3 15 12 20 255 9.7 0 9.8 9.6 09/22/2005 19:20:00 6.6 1.6 12.6 3 6.5 1.6 13 3 5 1.6 10.3 1.5 13 16 13 255 9.6 0 9.6 9.6 09/22/2005 19:30:00 7.5 1.5 13.3 4.2 7.5 1.5 13.7 4.2 6 1.5 11.1 2.6 21 14 347 255 9.6 0 9.8 9.6 09/22/2005 19:40:00 8.5 1.7 12.6 3 8.4 1.7 13 2.6 7 1.7 12.2 1.5 21 12 15 255 9.6 0 9.8 9.6 09/22/2005 19:50:00 8.4 1.8 13 3.8 8.3 1.8 13 4.2 6.6 1.9 12.2 2.3 21 13 18 255 9.6 0 9.8 9.6 09/22/2005 20:00:00 7.8 1.7 13.3 3.8 7.6 1.7 13.3 4.6 6.5 1.5 11.1 2.3 28 15 25 255 9.6 0 9.8 9.6 09/22/2005 20:10:00 7.8 1.6 12.2 4.6 7.7 1.6 12.2 4.2 6.5 1.7 11.1 3 31 13 26 255 9.6 0 9.8 9.6 09/22/2005 20:20:00 7.1 1.3 11.1 3.4 7 1.3 11.5 3.4 6 1.3 9.9 3 34 15 28 255 9.6 0 9.6 9.6 09/22/2005 20:30:00 7.6 1.3 11.5 4.2 7.5 1.3 11.5 4.2 6.4 1.4 9.9 3 41 15 32 255 9.6 0 9.8 9.6 09/22/2005 20:40:00 8.5 1.6 13 4.2 8.4 1.6 13.3 4.9 6.9 1.7 11.8 3.4 33 14 49 255 9.7 0 9.8 9.6 09/22/2005 20:50:00 7.2 1.5 11.5 4.2 7.1 1.5 11.1 3.8 5.9 1.7 10.3 2.3 38 17 49 255 9.7 0 9.8 9.6 09/22/2005 21:00:00 7.4 1.8 13.7 3 7.3 1.9 13.7 3.4 6.3 1.8 11.1 3 42 17 16 255 9.8 0 9.8 9.6 09/22/2005 21:10:00 6.9 1.4 9.9 3 6.8 1.4 10.3 2.6 5.7 1.5 9.1 1.5 40 13 9 255 9.6 0 9.8 9.6 09/22/2005 21:20:00 7.3 1.7 11.5 2.3 7.2 1.7 11.1 2.3 6.1 1.7 11.1 2.3 43 17 30 255 9.7 0 9.8 9.6 09/22/2005 21:30:00 6.1 1.5 11.1 3 6 1.6 10.3 3 4.8 1.5 8.8 1.9 56 20 37 255 9.6 0 9.8 9.6 09/22/2005 21:40:00 4.7 1 7.2 2.6 4.7 1.1 7.6 1.9 3.8 1.1 6.5 1.5 73 16 55 255 9.4 0 9.6 9.3 09/22/2005 21:50:00 4.8 1 7.2 1.9 4.7 1 7.2 1.5 3.9 1.1 7.2 1.1 77 13 66 255 9.2 0 9.6 9 09/22/2005 22:00:00 4.7 0.9 7.6 1.9 4.6 0.9 7.6 2.3 4 1 6.5 0.7 69 22 56 255 9.4 0 9.6 9.3 09/22/2005 22:10:00 5.5 1.5 9.5 2.6 5.4 1.5 9.9 2.3 4.4 1.3 8 1.1 75 17 81 255 9.4 0 9.6 9.3 09/22/2005 22:20:00 5.3 1.2 8.8 3 5.1 1.2 8.4 2.6 4.3 1.2 7.2 1.9 70 22 37 255 9.5 0 9.6 9.3 09/22/2005 22:30:00 5.7 1.3 8.8 2.6 5.6 1.4 8.8 1.9 4.7 1.3 8 1.5 65 15 68 255 9.5 0 9.6 9.6 09/22/2005 22:40:00 5.6 1.1 9.5 3 5.5 1.1 9.5 2.6 4.7 0.9 7.2 2.3 65 15 79 255 9.5 0 9.6 9.6 09/22/2005 22:50:00 5.5 1.5 9.1 2.3 5.4 1.6 9.1 1.5 4.3 1.5 8 0.7 62 22 69 255 9.7 0 9.8 9.6 09/22/2005 23:00:00 5 1.2 8 2.3 4.8 1.3 8.4 1.5 4 1.2 6.8 1.9 66 17 53 255 9.6 0 9.8 9.6 09/22/2005 23:10:00 4.7 1 7.6 2.6 4.5 1 7.2 1.9 3.9 1.1 6.5 1.5 79 14 60 255 9.6 0 9.8 9.6 09/22/2005 23:20:00 5.7 1.2 8.8 2.6 5.5 1.2 8.4 2.6 4.7 1.3 8 1.9 75 17 54 255 9.6 0 9.8 9.6 09/22/2005 23:30:00 4.8 1.2 8 1.9 4.7 1.3 8.4 1.5 3.9 1.1 6.5 1.5 82 20 87 255 9.9 0 10.1 9.8 09/22/2005 23:40:00 4.2 1.2 7.2 0.4 4 1.3 7.2 0.4 3.5 1.2 7.2 0.4 90 14 76 255 10 0 10.1 9.8 09/22/2005 23:50:00 5 1.3 8 1.9 4.9 1.3 7.6 1.5 4 1.3 7.2 1.5 75 15 90 255 10 0 10.3 9.8 09/23/2005 00:00:00 5.2 1.3 8.8 2.3 5.1 1.3 8.8 1.9 4.2 1.3 8.4 1.1 76 17 65 255 10.3 0 10.6 10.1 09/23/2005 00:10:00 5.1 1.1 8 2.6 4.9 1.1 7.6 2.3 4.1 1.2 7.6 1.5 94 17 81 255 10.5 0 10.6 10.3 09/23/2005 00:20:00 4.1 0.9 6.5 1.9 3.9 1 6.5 1.9 3.4 0.8 5.7 1.5 83 16 70 255 10.4 0 10.6 10.3 09/23/2005 00:30:00 4.3 1.2 8 1.1 4 1.3 7.6 0.7 3.4 1.3 6.5 0.4 79 17 83 255 10.5 0 10.6 10.3 09/23/2005 00:40:00 3.4 1.1 5.7 0.4 3.2 1.1 6.1 0.4 2.8 1.1 5.7 0.4 81 22 96 255 10.6 0 10.6 10.6 09/23/2005 00:50:00 3.8 1 6.8 1.5 3.7 1 5.7 1.5 2.9 1.1 5.3 0.4 85 18 91 255 10.6 0 10.6 10.6 09/23/2005 01:00:00 4.1 1 6.5 1.9 4 1 6.5 1.1 3.2 0.9 5.3 0.7 82 17 76 255 10.7 0 10.9 10.6 09/23/2005 01:10:00 4.2 1.1 7.6 1.5 4.1 1.1 7.2 1.5 3.3 1.1 6.1 0.7 77 16 56 255 10.9 0 11.1 10.9 09/23/2005 01:20:00 4.4 1.1 7.6 1.9 4.3 1.2 7.2 1.5 3.5 1.2 6.8 0.4 67 17 92 255 11 0 11.1 10.9 09/23/2005 01:30:00 4.6 1 7.6 1.5 4.4 1.1 7.2 0.7 3.6 1 6.8 0.7 81 17 85 255 11.1 0 11.1 10.9 09/23/2005 01:40:00 4.7 0.8 7.2 2.6 4.5 0.9 6.8 1.9 3.6 1 6.8 1.1 74 13 73 255 10.9 0 11.1 10.6 09/23/2005 01:50:00 5.2 1 8 3 5 1 7.6 3 4.2 1 6.8 1.5 74 13 77 255 10.7 0 10.9 10.6 09/23/2005 02:00:00 4.8 1.1 7.6 1.9 4.8 1.1 8 1.9 4 1.1 6.8 1.1 67 17 42 255 11 0 11.1 10.9 09/23/2005 02:10:00 4.6 0.9 6.8 1.9 4.5 0.9 6.5 1.9 3.5 1 6.5 0.7 61 14 42 255 11.1 0 11.1 11.1 09/23/2005 02:20:00 3.5 1 6.1 0.7 3.4 1.1 6.1 0.7 2.9 1 5.3 0.4 69 18 69 255 11.1 0 11.1 11.1 09/23/2005 02:30:00 4 0.7 5.7 1.5 3.9 0.7 5.7 1.9 3 0.8 4.9 1.1 69 15 73 255 11.1 0 11.1 10.9 09/23/2005 02:40:00 4.2 1 6.5 1.9 4.1 1 6.5 1.9 3.3 0.9 5.7 1.1 69 14 66 255 10.8 0 11.1 10.9 09/23/2005 02:50:00 4.3 0.8 6.1 1.5 4.2 0.9 6.1 0.7 3.3 0.8 5.7 1.1 74 11 65 255 10.8 0 10.9 10.6 09/23/2005 03:00:00 3.1 0.5 4.6 1.9 2.8 0.6 4.6 1.1 2.3 0.6 4.6 1.1 101 17 67 255 10.7 0 10.9 10.6 09/23/2005 03:10:00 2.6 0.7 4.2 1.1 2.3 0.8 4.2 0.4 2.2 0.8 3.8 0.4 136 19 136 255 10.6 0 10.6 10.6 09/23/2005 03:20:00 3.4 0.6 4.9 1.9 3.2 0.6 4.9 1.9 2.9 0.6 4.6 1.1 154 13 144 255 10.5 0 10.6 10.3 09/23/2005 03:30:00 3.7 0.7 4.9 1.5 3.5 0.7 4.9 0.7 3 0.7 4.6 1.1 134 11 142 255 10.3 0 10.6 10.3 09/23/2005 03:40:00 3 0.6 4.6 0.7 2.8 0.7 4.2 0.4 2.5 0.6 3.8 0.7 129 15 113 255 10.3 0 10.6 10.3 09/23/2005 03:50:00 3.5 0.5 4.6 1.9 3.3 0.5 4.6 1.5 2.5 0.7 4.2 0.7 101 11 113 255 10.5 0 10.6 10.3 09/23/2005 04:00:00 2.6 0.6 3.8 0.7 2.3 0.7 3.8 0.4 1.8 0.6 3.4 0.4 113 14 104 255 10.7 0.1 10.9 10.3 09/23/2005 04:10:00 2.9 0.6 4.9 0.7 2.7 0.6 4.6 0.7 2.3 0.6 4.2 1.1 130 15 116 255 10.4 0 10.6 10.3 09/23/2005 04:20:00 3.9 0.7 5.7 2.3 3.7 0.6 5.7 2.3 2.8 0.6 4.9 1.5 118 14 122 255 10.3 0 10.6 10.3 09/23/2005 04:30:00 4 0.7 6.1 2.3 3.8 0.7 5.7 1.9 2.9 0.6 4.9 1.1 115 13 102 255 10.3 0 10.6 10.3 09/23/2005 04:40:00 4.1 0.8 5.7 2.3 4 0.8 5.7 1.9 2.9 0.8 4.9 0.7 113 13 91 255 10.2 0 10.3 10.3 09/23/2005 04:50:00 3.9 0.5 5.7 2.6 3.7 0.5 5.3 2.3 3.3 0.6 4.9 1.9 129 9 129 255 10.2 0 10.3 10.3 09/23/2005 05:00:00 3.6 0.7 4.9 1.9 3.3 0.8 4.9 1.5 2.7 0.8 4.6 1.1 119 11 122 255 10.3 0 10.6 10.3 09/23/2005 05:10:00 3.8 0.7 5.7 1.5 3.6 0.7 5.3 1.5 2.9 0.7 4.6 1.1 120 14 113 255 10.5 0 10.9 10.3 09/23/2005 05:20:00 2.8 0.7 4.6 1.1 2.4 0.8 4.6 0.4 2.2 0.8 4.6 0.4 128 23 103 255 10.7 0 10.9 10.6 09/23/2005 05:30:00 2.2 0.8 3.8 0.4 1.8 0.9 3.8 0.4 1.8 0.7 3.4 0.4 114 33 86 255 10.6 0 10.6 10.6 09/23/2005 05:40:00 3.5 0.8 5.7 1.5 3.3 0.9 5.7 0.7 2.5 0.7 4.2 0.4 72 16 70 255 10.5 0 10.6 10.3 09/23/2005 05:50:00 2.8 0.8 4.9 0.7 2.5 0.8 4.6 0.7 2 0.8 4.6 0.4 95 21 54 255 10.9 0 11.1 10.6 09/23/2005 06:00:00 2.7 0.9 5.3 0.4 2.3 1 5.7 0.4 2.1 0.9 4.9 0.4 83 23 74 255 11.1 0 11.4 10.9 09/23/2005 06:10:00 1.9 0.8 4.6 0.4 1.5 0.8 4.2 0.4 1.2 0.8 3 0.4 83 32 44 255 11.3 0 11.4 11.1 09/23/2005 06:20:00 3.2 1 5.7 0.4 2.9 1 5.7 0.4 2.5 1 5.3 0.4 63 27 49 255 11.2 0 11.4 11.1 09/23/2005 06:30:00 3.1 0.6 4.9 1.1 2.8 0.7 4.6 0.7 2.6 0.7 4.6 0.7 42 17 18 255 11.7 0 11.7 11.4 09/23/2005 06:40:00 3.6 1.3 7.2 1.5 3.4 1.3 6.8 1.1 2.9 1.1 6.1 0.4 39 19 43 255 11.7 0 11.9 11.7 09/23/2005 06:50:00 2.2 0.5 3.4 1.1 1.9 0.7 3.4 0.4 1.7 0.6 3.4 0.4 64 27 89 255 11.7 0.1 11.9 11.4 09/23/2005 07:00:00 2.8 0.8 4.9 1.1 2.5 1 4.9 0.4 1.9 1 4.2 0.4 62 22 53 255 11.7 0 11.9 11.7 09/23/2005 07:10:00 2.3 0.5 3.4 0.7 2 0.7 3.8 0.4 1.6 0.6 3 0.4 64 24 53 255 11.5 0.1 11.7 11.1 09/23/2005 07:20:00 3 0.5 4.2 1.1 2.7 0.6 3.8 0.7 2.1 0.7 3.8 0.4 100 9 100 255 11.1 0 11.4 10.9 09/23/2005 07:30:00 2.8 0.5 4.2 1.1 2.5 0.6 3.8 0.4 2.1 0.5 3.4 0.7 108 12 112 255 11.1 0 11.4 10.9 09/23/2005 07:40:00 2.8 0.5 4.2 1.5 2.4 0.5 3.4 1.1 1.9 0.6 3.4 0.7 103 11 88 255 11.3 0 11.4 11.1 09/23/2005 07:50:00 2.8 0.7 4.9 1.1 2.3 0.8 4.6 0.4 1.9 0.7 3.8 0.4 119 13 104 255 11.2 0 11.4 11.1 09/23/2005 08:00:00 3 0.5 4.2 1.5 2.7 0.6 4.2 0.7 2.3 0.5 3.8 0.7 120 12 124 255 11.3 0 11.4 11.1 09/23/2005 08:10:00 2.9 0.5 4.2 1.5 2.5 0.5 3.8 1.1 2.2 0.5 3 1.1 125 12 124 255 11.5 0 11.7 11.4 09/23/2005 08:20:00 2.3 0.5 3.4 1.1 1.9 0.5 3.4 0.7 1.7 0.4 2.6 0.4 126 12 117 255 11.5 0 11.7 11.4 09/23/2005 08:30:00 1.7 0.7 3.4 0.4 1.1 0.7 3 0.4 0.9 0.6 3 0.4 118 15 116 255 11.7 0 11.7 11.7 09/23/2005 08:40:00 1.6 0.4 2.6 0.4 1 0.4 1.9 0.4 1 0.5 2.3 0.4 134 19 123 255 11.7 0 11.7 11.7 09/23/2005 08:50:00 2.2 0.3 3 1.5 1.7 0.4 3 0.4 1.7 0.3 2.6 0.7 131 9 126 255 11.7 0 11.9 11.7 09/23/2005 09:00:00 1.7 0.3 2.3 0.7 1 0.4 1.9 0.4 1 0.4 1.9 0.4 134 15 147 255 11.9 0 12.2 11.7 09/23/2005 09:10:00 1.9 0.4 2.6 1.1 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 118 12 112 255 12.1 0 12.2 11.9 09/23/2005 09:20:00 2 0.4 3 0.7 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 116 16 142 255 12.3 0 12.5 12.2 09/23/2005 09:30:00 2 0.4 3 0.7 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 120 17 132 255 12.6 0 12.7 12.5 09/23/2005 09:40:00 1.3 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 78 24 96 255 12.8 0 13 12.7 09/23/2005 09:50:00 1.4 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 119 22 96 255 13.1 0 13.3 13 09/23/2005 10:00:00 1.8 0.4 2.6 0.7 1.3 0.5 2.3 0.4 1.3 0.5 3 0.4 120 27 140 255 13.3 0 13.3 13.3 09/23/2005 10:10:00 1.9 0.5 3 0.4 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 84 16 52 255 13.3 0 13.5 13.3 09/23/2005 10:20:00 1.9 0.6 3 0.7 1.4 0.7 3 0.4 1.4 0.6 3 0.4 87 15 98 255 13.3 0 13.5 13.3 09/23/2005 10:30:00 1.7 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.2 0.5 2.6 0.4 126 17 123 255 13.3 0 13.3 13.3 09/23/2005 10:40:00 1.8 0.4 2.6 0.7 1.2 0.5 2.3 0.4 1.2 0.5 2.6 0.4 116 18 139 255 13.4 0 13.5 13.3 09/23/2005 10:50:00 2 0.6 3 0.4 1.6 0.6 2.6 0.4 1.5 0.6 2.6 0.4 92 13 91 255 13.7 0 13.8 13.5 09/23/2005 11:00:00 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 110 12 100 255 13.9 0 13.8 13.8 09/23/2005 11:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 120 56 53 255 14 0 14.4 13.8 09/23/2005 11:20:00 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 147 38 108 255 14.2 0 14.4 14.1 09/23/2005 11:30:00 1.8 0.5 3 0.7 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 118 24 79 255 14.2 0 14.4 14.1 09/23/2005 11:40:00 2.4 0.4 3.8 1.1 2 0.5 3.4 0.4 1.6 0.5 3 0.4 99 13 93 255 14.4 0 14.6 14.4 09/23/2005 11:50:00 1.3 0.7 2.6 0.4 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 89 15 102 255 14.6 0 14.9 14.6 09/23/2005 12:00:00 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.5 0.4 90 16 86 255 15 0 15.2 14.9 09/23/2005 12:10:00 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.9 0.4 103 11 100 255 15.1 0 15.5 15.2 09/23/2005 12:20:00 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 45 49 35 255 15.4 0 16 15.5 09/23/2005 12:30:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 26 64 136 255 15.6 0 16.3 15.5 09/23/2005 12:40:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 132 0 132 255 15.8 0 16.3 15.7 09/23/2005 12:50:00 1.2 0.5 3 0.4 0.6 0.5 2.6 0.4 0.8 0.4 2.3 0.4 135 49 199 255 16.1 0 16.8 16 09/23/2005 13:00:00 1.6 0.5 3 0.4 1.2 0.6 2.6 0.4 1.5 0.5 2.6 0.4 154 27 119 255 16.1 0 16.8 16.3 09/23/2005 13:10:00 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.2 0.6 2.6 0.4 154 17 145 255 16.2 0 16.8 16.3 09/23/2005 13:20:00 2.4 0.7 4.6 1.1 2.2 0.7 4.2 0.4 2.3 0.7 3.8 0.4 151 38 112 255 16.4 0 16.8 16.3 09/23/2005 13:30:00 2.1 0.7 4.6 0.4 1.8 0.8 4.2 0.4 1.7 0.7 3.4 0.4 95 21 76 255 16.5 0 16.8 16.6 09/23/2005 13:40:00 2.9 0.9 5.7 0.7 2.7 1 5.3 0.4 2.5 1 5.3 0.4 81 21 62 255 16.3 0.1 16.8 16.3 09/23/2005 13:50:00 2.5 0.8 4.9 0.4 2.1 0.9 4.9 0.4 1.9 0.8 4.2 0.4 107 24 116 255 16.1 0 16.8 16 09/23/2005 14:00:00 2.6 0.6 4.2 1.1 2.2 0.7 3.4 0.4 2.1 0.6 3.8 0.4 95 15 122 255 15.9 0 16.6 15.7 09/23/2005 14:10:00 1.6 0.5 3 0.4 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 43 18 58 255 16.3 0.1 16.8 16 09/23/2005 14:20:00 1 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.7 0.4 1.9 0.4 39 23 39 255 16.6 0 17.1 16.6 09/23/2005 14:30:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 104 39 64 255 17.1 0.2 17.7 16.8 09/23/2005 14:40:00 1.6 0.5 2.6 0.4 1.2 0.6 2.3 0.4 1.3 0.6 2.6 0.4 23 12 37 255 17.3 0.1 17.7 16.8 09/23/2005 14:50:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 18 6 23 255 16.9 0 17.1 16.8 09/23/2005 15:00:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 30 47 108 255 17 0 17.1 16.8 09/23/2005 15:10:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 51 27 81 255 16.8 0 17.1 16.8 09/23/2005 15:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 42 5 48 255 16.7 0 16.8 16.6 09/23/2005 15:30:00 0.8 0.7 3 0.4 0.7 0.5 2.6 0.4 0.7 0.6 3 0.4 32 86 248 255 16.6 0 16.8 16.6 09/23/2005 15:40:00 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 1.3 0.6 3 0.4 237 17 240 255 16.5 0 16.8 16.3 09/23/2005 15:50:00 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 1.5 0.5 2.6 0.4 244 17 246 255 16.6 0 16.8 16.3 09/23/2005 16:00:00 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 221 19 235 255 16.4 0.1 16.8 16.3 09/23/2005 16:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 269 61 328 255 16.1 0 16.8 16.3 09/23/2005 16:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 212 64 177 255 16.2 0.1 16.8 16.3 09/23/2005 16:30:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 317 10 319 255 16.1 0 16.6 16 09/23/2005 16:40:00 0.9 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 241 8 252 255 15.7 0 16.3 15.7 09/23/2005 16:50:00 0.8 0.6 2.3 0.4 0.5 0.4 1.9 0.4 0.7 0.5 2.3 0.4 227 28 207 255 15.4 0 16 15.2 09/23/2005 17:00:00 2.8 1.4 6.8 0.7 2.4 1.6 6.5 0.4 1.8 1.2 4.9 0.4 1 39 348 255 15 0 15.7 14.9 09/23/2005 17:10:00 3.3 1 5.3 1.1 3 1.2 5.3 0.7 2.4 1.2 5.3 0.4 8 24 359 255 14.8 0.1 15.5 14.6 09/23/2005 17:20:00 2.7 0.8 4.9 1.1 2.6 0.8 4.6 1.1 2.3 0.8 4.6 0.7 39 24 353 255 14.7 0 15.2 14.6 09/23/2005 17:30:00 3.5 0.6 4.9 1.9 3.3 0.6 5.3 1.9 2.9 0.7 4.9 1.1 81 11 86 255 14.6 0 15.2 14.6 09/23/2005 17:40:00 4.2 1.1 7.6 1.9 4 1.2 7.6 1.5 3.3 1 6.1 1.1 60 18 63 255 14.5 0 15.2 14.4 09/23/2005 17:50:00 4.2 0.8 6.1 2.3 4.1 0.8 6.1 1.9 3.4 1 5.7 0.7 54 15 59 255 14.5 0 14.9 14.4 09/23/2005 18:00:00 3.4 1.3 6.1 0.4 3.1 1.5 6.1 0.4 2.9 1.3 6.1 0.4 58 19 75 255 14.1 0.1 14.6 13.8 09/23/2005 18:10:00 3.4 0.9 6.5 1.5 3.2 1 6.1 1.1 2.5 0.8 4.9 0.7 57 19 32 255 13.5 0 13.8 13.3 09/23/2005 18:20:00 3 0.8 4.9 1.1 2.9 0.8 4.9 1.1 2.2 0.7 4.6 0.4 66 22 70 255 13.3 0 13.3 13 09/23/2005 18:30:00 2.3 0.7 4.6 1.1 2 0.8 4.6 0.4 1.6 0.9 4.2 0.4 57 16 63 255 13.3 0 13.3 13 09/23/2005 18:40:00 2.5 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.7 0.7 3.8 0.4 52 19 34 255 12.5 0.2 13 12.2 09/23/2005 18:50:00 2.5 1.5 7.6 0.4 2.2 1.7 7.6 0.4 1.7 1.4 6.1 0.4 73 28 25 255 11.9 0.1 12.2 11.7 09/23/2005 19:00:00 3.8 1 6.5 1.5 3.7 1 6.5 1.1 3 0.8 5.3 1.1 53 17 35 255 11.7 0 11.9 11.7 09/23/2005 19:10:00 3.8 0.9 7.2 1.9 3.7 0.9 7.2 1.9 2.8 0.8 5.7 1.1 73 15 21 255 11.7 0 11.9 11.7 09/23/2005 19:20:00 3.3 0.8 6.1 1.1 3.2 0.8 5.7 0.7 2.5 0.7 4.6 0.7 61 22 32 255 11.5 0 11.7 11.4 09/23/2005 19:30:00 4.2 1.1 7.2 2.3 4.1 1.1 7.6 1.9 3.3 1.2 6.5 1.1 35 17 40 255 11.5 0 11.7 11.4 09/23/2005 19:40:00 5.6 1.2 8.4 2.3 5.5 1.2 8.4 2.6 4.5 1.2 8 1.9 56 19 68 255 11.7 0 11.7 11.7 09/23/2005 19:50:00 5.9 1.3 9.1 3.4 5.9 1.4 9.5 3.4 4.6 1.4 8 1.5 66 19 59 255 11.6 0 11.7 11.4 09/23/2005 20:00:00 6.3 1.4 11.5 3.4 6.3 1.4 11.5 3.4 5.1 1.3 9.9 1.5 55 15 49 255 11.9 0.1 11.9 11.7 09/23/2005 20:10:00 8 1.7 12.6 3.8 8 1.7 12.2 4.2 6.5 1.7 10.3 3 50 15 43 255 12.2 0.1 12.5 11.9 09/23/2005 20:20:00 9 1.7 13 4.2 9 1.7 13.3 4.2 7.5 1.6 11.5 3.8 44 15 24 255 12.5 0 12.7 12.5 09/23/2005 20:30:00 9.6 1.7 14.1 5.3 9.5 1.9 14.5 4.9 8.1 2.1 13.3 3.4 43 15 32 255 12.7 0 12.7 12.5 09/23/2005 20:40:00 9.7 1.8 15.3 5.3 9.6 1.9 15.6 4.9 8 2 13.3 3.4 41 15 54 255 12.8 0 12.7 12.7 09/23/2005 20:50:00 8.6 1.8 14.9 3.8 8.6 1.8 14.9 4.2 7.3 1.9 14.5 3 44 15 35 255 12.5 0 12.7 12.5 09/23/2005 21:00:00 9.4 1.6 13 4.2 9.4 1.7 13.3 4.2 8.1 1.7 11.8 3.8 49 12 56 255 12.5 0 12.7 12.5 09/23/2005 21:10:00 8.8 2 14.5 4.6 8.8 2 14.5 4.2 7.4 1.7 12.2 3.8 48 13 50 255 12.4 0 12.5 12.2 09/23/2005 21:20:00 8.4 1.9 14.5 3.4 8.4 1.9 15.3 3.4 7 1.8 12.6 3 46 16 40 255 12.2 0 12.5 11.9 09/23/2005 21:30:00 8.3 1.6 12.6 4.9 8.3 1.6 12.6 4.6 7.1 1.7 12.2 3.4 45 15 18 255 12.1 0 12.2 11.9 09/23/2005 21:40:00 8.3 1.7 13.3 3.8 8.2 1.7 13.3 3.4 7.1 1.7 11.5 2.6 42 13 31 255 12.2 0 12.2 11.9 09/23/2005 21:50:00 7.6 1.7 12.2 3.8 7.6 1.6 11.8 3.4 6.3 1.5 11.1 2.6 38 13 51 255 12 0 12.2 11.9 09/23/2005 22:00:00 7.2 1.6 11.8 4.2 7.1 1.7 12.2 3.4 6.1 1.7 9.5 2.3 32 13 49 255 11.9 0.1 12.2 11.7 09/23/2005 22:10:00 6.4 1.2 9.9 4.2 6.4 1.2 9.9 4.2 5.2 1.2 8.4 2.6 40 12 28 255 11.7 0 11.7 11.7 09/23/2005 22:20:00 6.4 1.8 12.2 2.6 6.3 1.8 12.2 2.3 5.2 1.8 11.1 1.1 37 17 56 255 11.4 0.1 11.7 11.1 09/23/2005 22:30:00 6.1 1.3 11.1 3.4 6 1.3 11.1 3.4 4.9 1.3 10.7 1.9 36 14 48 255 11.2 0 11.4 11.1 09/23/2005 22:40:00 6.5 1.5 10.3 3.4 6.4 1.5 10.3 3 5.6 1.5 9.9 2.6 36 15 42 255 11.1 0 11.4 11.1 09/23/2005 22:50:00 6.9 1.7 11.8 3 6.9 1.7 11.5 3.4 5.8 1.6 10.3 2.3 31 14 26 255 11 0 11.1 10.9 09/23/2005 23:00:00 7.1 1.5 11.5 3.8 7 1.5 11.5 3.8 5.8 1.6 9.9 2.3 29 17 8 255 10.9 0 11.1 10.9 09/23/2005 23:10:00 6.5 1.8 10.7 2.3 6.4 1.7 11.1 2.6 5.4 1.7 9.5 1.5 28 16 35 255 10.9 0 10.9 10.9 09/23/2005 23:20:00 7.5 1.4 12.6 4.2 7.4 1.5 12.2 3.8 6.3 1.5 10.3 2.6 28 13 24 255 10.9 0 10.9 10.9 09/23/2005 23:30:00 7.1 1.4 10.7 3.8 7.1 1.4 11.1 3.8 5.9 1.6 11.1 2.6 29 17 16 255 10.9 0 11.1 10.9 09/23/2005 23:40:00 6.7 2.2 14.5 2.6 6.7 2.1 14.5 3 5.5 2 13 2.3 33 16 38 255 10.6 0 10.9 10.6 09/23/2005 23:50:00 8.7 1.8 14.1 5.3 8.7 1.8 14.1 4.9 7.4 1.8 13 3.4 40 13 22 255 10.7 0 10.9 10.6 09/24/2005 00:00:00 7.3 1.5 12.6 3.8 7.2 1.5 12.6 3.8 6.1 1.3 10.7 2.6 36 13 26 255 10.5 0 10.6 10.6 09/24/2005 00:10:00 6.4 1.9 11.8 2.3 6.4 2 11.8 2.3 5.3 1.7 11.1 1.5 34 14 27 255 10.4 0 10.6 10.3 09/24/2005 00:20:00 6.3 1.1 9.1 3.4 6.3 1.2 9.1 2.6 5.3 1.1 8.4 1.9 36 15 37 255 10.2 0 10.3 10.3 09/24/2005 00:30:00 5.2 1.7 9.9 2.3 5.2 1.7 9.9 1.9 4.3 1.7 10.3 1.5 49 23 40 255 10.4 0 10.6 10.3 09/24/2005 00:40:00 4.9 1.3 8.4 2.3 5 1.2 8.4 2.3 4 1.2 7.2 1.5 71 16 68 255 10.2 0 10.6 10.1 09/24/2005 00:50:00 5.8 1.4 9.5 3 5.7 1.3 9.1 3 4.8 1.5 8.8 1.5 62 18 60 255 10.3 0 10.6 10.3 09/24/2005 01:00:00 5.6 1.1 8.4 3 5.6 1.2 8.4 3 4.5 1 7.2 2.3 58 15 45 255 10.4 0 10.6 10.3 09/24/2005 01:10:00 5.5 1.2 8.4 2.6 5.5 1.2 8.4 2.3 4.5 1.4 7.6 1.1 61 17 54 255 10.3 0 10.6 10.3 09/24/2005 01:20:00 3.9 1.3 8 1.9 3.8 1.2 7.6 1.5 3 1.1 7.6 0.7 86 17 87 255 10.3 0 10.6 10.3 09/24/2005 01:30:00 2.3 1.1 5.3 0.4 2.2 1.1 5.3 0.4 1.7 1 4.9 0.4 79 22 95 255 10.4 0 10.6 10.3 09/24/2005 01:40:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.9 0.5 1.9 0.4 261 76 283 255 10 0 10.6 9.8 09/24/2005 01:50:00 3.2 1.7 8.4 0.4 3.1 1.7 8 0.4 2.8 1.3 7.2 0.4 196 66 256 255 9.9 0 10.1 9.8 09/24/2005 02:00:00 2.6 1.5 6.1 0.4 2.5 1.6 5.7 0.4 2.3 1.4 5.3 0.4 74 107 252 255 10 0 10.1 9.8 09/24/2005 02:10:00 5.1 2.2 11.8 0.7 5 2.2 11.1 0.4 4 1.8 10.3 0.4 264 29 208 255 10.2 0 10.6 9.8 09/24/2005 02:20:00 6.4 2.4 12.2 0.7 6.3 2.4 12.2 0.4 4.9 2.1 10.7 0.4 276 27 297 255 10.5 0 10.6 10.3 09/24/2005 02:30:00 6.7 1.9 11.8 1.9 6.5 2 11.5 1.5 5.2 1.9 11.5 1.1 279 22 306 255 10.5 0 10.6 10.3 09/24/2005 02:40:00 6.3 1.7 11.1 3 6 1.7 11.5 1.9 4.8 1.7 10.3 0.7 275 23 290 255 10.5 0 10.6 10.3 09/24/2005 02:50:00 5.6 1.9 10.7 2.3 5.3 1.9 11.5 0.7 4.1 1.7 8.4 0.7 271 29 295 255 10.5 0 10.6 10.3 09/24/2005 03:00:00 5.3 1.8 10.7 0.4 5 1.8 10.7 0.4 3.9 1.7 8.8 0.4 254 27 261 255 10.5 0 10.6 10.6 09/24/2005 03:10:00 5.2 1.8 12.2 0.7 5 1.8 11.1 0.4 3.9 1.7 8.8 0.4 247 22 255 255 10.5 0 10.6 10.3 09/24/2005 03:20:00 6.2 2.1 13 1.9 6.1 2.1 13.3 1.9 4.3 2.2 11.5 0.7 248 24 291 255 10.3 0.1 10.6 10.3 09/24/2005 03:30:00 7.7 2.4 14.1 2.3 7.7 2.4 14.1 2.6 5.8 2.4 13 0.7 259 26 249 255 10.2 0 10.3 10.3 09/24/2005 03:40:00 8.5 2.7 15.6 2.3 8.3 2.7 15.6 1.9 6.5 2.6 13.3 0.7 256 22 267 255 10.2 0 10.3 10.1 09/24/2005 03:50:00 8.6 3.1 19.5 1.1 8.6 3.1 19.9 1.5 6.8 2.9 14.9 1.5 257 33 258 255 10.2 0 10.3 10.1 09/24/2005 04:00:00 8.9 3.2 17.2 2.6 8.8 3.2 16.8 1.9 6.7 2.9 14.9 1.1 261 32 256 255 10.1 0 10.3 10.1 09/24/2005 04:10:00 7.6 2.7 14.1 2.6 7.5 2.8 13.7 1.9 5.4 2.6 12.6 0.7 267 29 289 255 10.1 0 10.3 10.1 09/24/2005 04:20:00 8.1 2.8 15.6 1.1 7.9 2.8 16.1 2.3 6.1 2.6 16.8 0.7 270 29 274 255 10.2 0 10.3 10.1 09/24/2005 04:30:00 7.3 2.7 14.5 2.3 7.1 2.7 14.1 1.1 5.8 2.3 13.3 1.5 267 27 273 255 10.3 0 10.6 10.3 09/24/2005 04:40:00 7.6 2.7 16.4 1.9 7.5 2.7 17.2 2.6 5.9 2.4 14.9 1.5 267 24 276 255 10.2 0 10.6 10.1 09/24/2005 04:50:00 7.9 2.7 16.1 2.3 7.9 2.6 15.6 2.3 5.8 2.5 13.3 0.7 267 26 257 255 10.2 0 10.3 10.1 09/24/2005 05:00:00 7.3 2.4 14.5 2.3 7.2 2.4 15.3 1.9 5.7 2.2 14.5 1.1 263 29 253 255 10.2 0 10.3 10.3 09/24/2005 05:10:00 6.5 2.5 13 0.7 6.4 2.5 13.3 0.4 4.9 2.1 11.8 0.4 263 24 276 255 10.2 0 10.3 10.1 09/24/2005 05:20:00 5.5 2.2 10.3 1.5 5.4 2.4 11.1 0.7 3.9 1.8 10.3 0.4 256 33 273 255 10.2 0 10.3 10.1 09/24/2005 05:30:00 7.3 2.6 14.5 1.1 7.2 2.6 14.1 0.7 5.5 2.2 12.2 0.7 260 23 256 255 10.2 0 10.3 10.1 09/24/2005 05:40:00 7.1 2.4 13.3 1.5 6.9 2.4 13.3 1.5 5.1 2.5 11.8 0.7 259 24 255 255 10.1 0 10.3 10.1 09/24/2005 05:50:00 6.5 2.5 14.1 0.7 6.4 2.6 14.1 1.1 5 2.4 11.8 0.4 265 29 261 255 10.2 0 10.3 10.1 09/24/2005 06:00:00 6.4 2.2 13.3 1.5 6.4 2.1 13.3 1.1 4.9 2 9.9 0.7 264 29 287 255 10.2 0 10.3 10.1 09/24/2005 06:10:00 6.9 2.5 12.6 1.5 6.9 2.5 13 1.5 5.5 2.1 11.1 1.1 258 26 275 255 10.2 0 10.3 10.1 09/24/2005 06:20:00 6.5 2.5 15.6 1.1 6.4 2.5 15.6 0.7 4.9 2.1 13.3 1.1 259 24 277 255 10.1 0 10.3 9.8 09/24/2005 06:30:00 6.5 2 12.6 1.1 6.4 2 12.2 1.5 4.9 1.8 10.7 1.1 255 27 247 255 10 0 10.1 9.8 09/24/2005 06:40:00 6.5 2.2 12.6 1.9 6.4 2.3 12.6 1.1 4.6 2 11.5 1.1 259 32 261 255 10.1 0 10.3 10.1 09/24/2005 06:50:00 7.6 2.3 14.9 3 7.5 2.4 14.1 1.5 6 2.3 13.7 1.1 266 26 264 255 10.2 0 10.3 10.1 09/24/2005 07:00:00 7 3.1 14.1 0.7 6.9 3.1 14.1 0.7 5.4 2.8 14.5 0.4 277 29 262 255 10.1 0 10.3 10.1 09/24/2005 07:10:00 6.7 2.5 14.1 1.5 6.6 2.6 13.3 0.4 5.3 2.3 13.7 0.4 271 39 293 255 10.3 0 10.6 10.3 09/24/2005 07:20:00 7.1 3.2 16.4 1.5 6.9 3.2 16.4 0.7 5.3 2.8 15.6 1.1 264 32 269 255 10.3 0 10.6 10.3 09/24/2005 07:30:00 7.3 2.5 16.8 1.5 7.2 2.7 16.1 1.1 5.5 2.4 12.6 0.4 265 28 255 255 10.2 0 10.3 10.3 09/24/2005 07:40:00 7.9 2.8 17.6 1.9 7.9 2.8 17.6 2.3 6.1 2.6 13.7 1.5 271 30 275 255 10.3 0 10.6 10.3 09/24/2005 07:50:00 6.7 2.2 13.7 1.1 6.5 2.3 13.3 1.1 5.4 2.3 11.8 0.4 268 33 288 255 10.4 0 10.6 10.3 09/24/2005 08:00:00 7.5 2.2 14.1 2.6 7.3 2.3 13.7 3 5.4 2.2 13.3 1.1 258 23 236 255 10.4 0 10.6 10.3 09/24/2005 08:10:00 8.5 2.9 17.9 1.5 8.5 3.1 17.9 1.1 6.5 2.8 15.3 1.1 264 30 270 255 10.3 0 10.6 10.3 09/24/2005 08:20:00 7.9 2.7 16.1 1.9 8 2.8 16.8 1.5 6.1 2.7 13.7 1.1 267 28 259 255 10.5 0 10.6 10.6 09/24/2005 08:30:00 8.9 2.6 16.8 3 8.9 2.7 16.4 2.6 6.8 2.7 15.3 1.1 266 26 255 255 10.4 0 10.6 10.3 09/24/2005 08:40:00 7.1 2.6 15.6 0.7 7.2 2.6 14.9 1.9 5.5 2.3 13.3 0.7 263 33 260 255 10 0 10.3 9.8 09/24/2005 08:50:00 8.1 2.7 15.3 2.3 8 2.7 15.3 1.9 6.1 2.5 14.5 1.5 268 29 279 255 9.9 0 10.3 9.8 09/24/2005 09:00:00 7.3 2.2 13 2.6 7.2 2.1 13 3 5.3 2.2 10.7 0.7 264 28 321 255 10.4 0 10.6 10.3 09/24/2005 09:10:00 7.2 2.5 13.7 2.3 7 2.5 13.3 1.9 5.5 2.3 12.6 1.1 268 30 287 255 10.6 0 10.9 10.6 09/24/2005 09:20:00 6.7 2.5 14.9 2.3 6.5 2.6 15.6 1.1 5.4 2.3 13.7 1.5 276 23 274 255 10.7 0 10.9 10.6 09/24/2005 09:30:00 7.2 2.8 14.9 0.7 6.9 2.9 14.9 0.4 5.6 2.3 11.8 1.5 274 27 286 255 10.7 0 10.9 10.6 09/24/2005 09:40:00 5.9 2.2 11.8 1.9 5.8 2.3 11.8 1.1 4.5 2 11.1 0.7 272 24 260 255 10.8 0 10.9 10.9 09/24/2005 09:50:00 6.2 2.4 12.6 1.5 5.8 2.5 12.2 0.7 4.4 2 9.9 0.4 269 30 276 255 10.9 0 11.1 10.9 09/24/2005 10:00:00 6.8 2.5 13 1.5 6.7 2.6 13 1.5 5.3 2.3 12.2 1.5 268 27 262 255 11 0 11.1 10.9 09/24/2005 10:10:00 6.3 2.3 14.9 1.5 6.2 2.3 14.1 1.5 5 2.3 13.7 0.7 273 24 270 255 11 0 11.1 10.9 09/24/2005 10:20:00 6.1 2.4 14.1 0.7 6.2 2.5 13.7 0.7 4.6 2 11.1 0.7 264 33 280 255 11.1 0 11.1 11.1 09/24/2005 10:30:00 7.1 2.7 14.5 0.4 7.1 2.7 13.7 0.7 5.6 2.5 11.5 0.4 260 30 287 255 11.1 0 11.1 11.1 09/24/2005 10:40:00 5.1 2.1 10.7 1.1 5 2.1 10.3 0.4 4.1 1.9 9.9 0.7 257 35 223 255 11.1 0 11.4 11.1 09/24/2005 10:50:00 5.5 2.2 11.8 1.9 5.4 2.3 11.8 1.1 4.3 1.9 11.1 0.4 255 27 253 255 11.5 0 11.7 11.4 09/24/2005 11:00:00 6.9 2.5 14.1 2.3 6.7 2.5 14.1 2.3 5.5 2.1 13 1.1 262 23 251 255 11.7 0 11.7 11.7 09/24/2005 11:10:00 6.2 2.4 14.5 1.5 6 2.5 14.1 1.1 4.8 2.2 13.7 1.1 252 30 273 255 11.7 0 11.7 11.7 09/24/2005 11:20:00 6.7 2.5 14.5 1.5 6.6 2.4 13.7 1.5 5.1 2.3 12.2 0.7 258 23 249 255 11.7 0 11.9 11.7 09/24/2005 11:30:00 6.6 2.1 11.5 2.6 6.6 2.2 11.8 1.9 5.2 2 11.1 1.5 262 32 267 255 11.8 0 11.9 11.7 09/24/2005 11:40:00 6.9 2.6 13.3 0.7 6.7 2.7 14.1 0.7 5.3 2.5 12.6 1.5 254 30 271 255 11.7 0 11.9 11.7 09/24/2005 11:50:00 6.3 2.6 13.3 0.7 6.3 2.7 13.3 1.1 4.6 2.5 13 0.7 258 28 268 255 11.8 0 11.9 11.7 09/24/2005 12:00:00 5.3 1.8 10.3 1.1 5.2 2 10.3 0.7 3.9 1.7 8.8 1.1 258 38 261 255 12.2 0.1 12.5 11.9 09/24/2005 12:10:00 5.7 1.7 9.9 0.7 5.6 1.7 9.5 0.7 4.5 1.6 9.1 0.4 270 28 253 255 12.7 0.2 13.3 12.5 09/24/2005 12:20:00 6.2 1.8 10.3 1.5 6 1.9 10.7 1.1 4.7 2 9.5 0.7 268 28 266 255 14.2 0.4 15.2 13.3 09/24/2005 12:30:00 5.5 2.1 10.3 0.4 5.4 2.2 10.7 0.4 4.2 2 10.3 0.7 268 33 263 255 14.8 0 15.2 14.6 09/24/2005 12:40:00 5.5 2.1 10.7 0.7 5.3 2.2 9.9 0.7 4.3 1.9 9.1 0.4 282 33 252 255 14.8 0 15.5 14.6 09/24/2005 12:50:00 5.6 1.9 9.9 1.1 5.4 2 10.3 0.4 4.6 1.8 10.3 0.7 279 29 258 255 14.5 0.3 15.2 14.1 09/24/2005 13:00:00 4.4 1.4 8.8 1.5 4.1 1.4 9.1 1.1 3.5 1.6 9.1 0.4 287 24 292 255 14.2 0 14.9 14.1 09/24/2005 13:10:00 4.5 1.5 8.8 1.9 4.1 1.7 8.8 0.7 3.3 1.5 7.6 0.4 287 39 291 255 14.8 0.3 16 14.6 09/24/2005 13:20:00 2.9 0.9 5.3 0.7 2.5 0.9 5.3 0.4 2.2 0.8 4.9 0.4 313 39 317 255 15.2 0.1 16.3 15.2 09/24/2005 13:30:00 2.7 1.5 6.1 0.4 2.3 1.4 6.1 0.4 1.9 1.1 5.3 0.4 320 51 322 255 15.7 0.3 16.3 14.9 09/24/2005 13:40:00 4.1 1.3 8.4 1.5 3.8 1.4 7.6 0.7 3 1.3 7.6 0.4 281 28 248 255 14.2 0.4 15.2 13.3 09/24/2005 13:50:00 2.9 0.9 5.3 0.4 2.6 1 5.3 0.4 2.4 0.9 5.3 0.4 286 23 257 255 13.6 0.3 14.4 13 09/24/2005 14:00:00 3.1 1.1 6.1 0.4 2.9 1.2 6.1 0.4 2.5 1.1 6.1 0.4 277 30 270 255 14.4 0.2 14.9 13.8 09/24/2005 14:10:00 3.2 0.9 6.1 1.5 2.8 1 5.7 0.7 2.5 0.9 5.7 0.4 322 24 295 255 14 0.1 14.9 13.8 09/24/2005 14:20:00 3 1 4.9 0.7 2.5 1.2 4.9 0.4 2 1 4.6 0.4 338 29 341 255 14.5 0.3 15.2 13.8 09/24/2005 14:30:00 2.9 0.8 5.3 1.1 2.5 1 4.9 0.4 2.2 1 4.2 0.4 349 23 352 255 13.4 0.2 14.1 13 09/24/2005 14:40:00 2 0.9 4.6 0.4 1.5 1 4.6 0.4 1.5 0.8 3.8 0.4 314 28 293 255 12.9 0 13.3 12.7 09/24/2005 14:50:00 2.1 0.8 3.4 0.4 1.7 1 3.4 0.4 1.5 0.7 3 0.4 349 27 342 255 12.9 0.1 13.8 12.7 09/24/2005 15:00:00 1.7 1 4.2 0.4 1.4 0.9 3.4 0.4 1.1 0.7 3.4 0.4 332 23 321 255 13.7 0.1 14.4 13.3 09/24/2005 15:10:00 1.6 0.7 3 0.4 1.2 0.7 3 0.4 1.2 0.6 2.6 0.4 320 38 312 255 13.9 0 14.6 13.8 09/24/2005 15:20:00 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 356 19 7 255 13.9 0 14.4 13.5 09/24/2005 15:30:00 1.2 0.7 3 0.4 0.8 0.6 3 0.4 0.9 0.6 2.3 0.4 314 18 308 255 13.5 0 14.1 13.3 09/24/2005 15:40:00 1.8 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1.2 0.7 2.6 0.4 10 20 31 255 13.1 0.1 13.8 12.7 09/24/2005 15:50:00 2.3 0.4 3.4 1.5 2 0.4 3 1.1 1.8 0.5 3 0.4 38 16 43 255 12.7 0.1 13 12.5 09/24/2005 16:00:00 1.9 0.7 3 0.4 1.6 0.7 2.6 0.4 1.4 0.7 2.6 0.4 32 13 23 255 12.1 0 12.5 11.9 09/24/2005 16:10:00 3.9 1.8 8.8 0.4 3.7 1.9 8.4 0.4 2.8 1.5 6.8 0.4 252 43 218 255 11.3 0.4 11.9 10.3 09/24/2005 16:20:00 2.9 1.3 6.1 0.4 2.6 1.5 5.7 0.4 1.6 0.9 4.6 0.4 343 53 3 255 9.8 0.3 10.6 9.6 09/24/2005 16:30:00 2.8 0.9 4.6 0.7 2.6 1 4.2 0.4 2 1 3.8 0.4 34 27 39 255 9.4 0 9.6 9.3 09/24/2005 16:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 81 49 310 255 9.2 0 9.6 9 09/24/2005 16:50:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.3 1.5 0.4 73 21 73 255 9.2 0 9.3 9 09/24/2005 17:00:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 127 61 265 255 9.2 0 9.3 9 09/24/2005 17:10:00 1.5 0.8 4.6 0.4 1.2 0.8 4.6 0.4 1 0.7 4.2 0.4 301 23 290 255 9 0 9.3 8.8 09/24/2005 17:20:00 2.5 1.1 5.3 0.4 2.2 1.2 4.9 0.4 1.4 1 4.6 0.4 232 22 232 255 8.9 0 9 8.8 09/24/2005 17:30:00 3 0.9 5.7 0.7 2.7 1 6.1 0.4 1.9 0.9 4.2 0.4 234 17 219 255 9 0 9.3 9 09/24/2005 17:40:00 2.5 0.8 5.3 0.7 2.2 0.8 4.6 0.4 1.4 0.7 4.6 0.4 234 21 273 255 9.4 0 9.6 9 09/24/2005 17:50:00 2 0.7 4.2 0.4 1.7 0.8 3.8 0.4 1 0.5 2.6 0.4 241 15 258 255 9.4 0 9.6 9.3 09/24/2005 18:00:00 1.8 1 4.6 0.4 1.3 1 4.2 0.4 1.1 0.8 3 0.4 256 21 230 255 9.4 0 9.6 9.3 09/24/2005 18:10:00 0.6 0.5 3 0.4 0.5 0.3 2.3 0.4 0.4 0.1 1.1 0.4 243 26 240 255 9.2 0 9.3 9 09/24/2005 18:20:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 97 32 115 255 9 0 9 9 09/24/2005 18:30:00 1.8 0.3 2.6 1.1 1.6 0.3 2.6 0.7 1.6 0.4 2.6 0.4 100 9 124 255 9 0 9 9 09/24/2005 18:40:00 1.4 0.7 2.6 0.4 1.1 0.7 3 0.4 1.3 0.8 3 0.4 126 21 100 255 8.9 0 9 8.8 09/24/2005 18:50:00 0.9 0.5 3 0.4 0.6 0.5 2.6 0.4 0.7 0.4 1.9 0.4 165 47 221 255 8.6 0.1 8.8 8.5 09/24/2005 19:00:00 1.1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.5 0.4 1.9 0.4 240 17 241 255 8.5 0 8.8 8.5 09/24/2005 19:10:00 0.8 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.1 0.4 258 11 244 255 8.3 0 8.5 8.3 09/24/2005 19:20:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 2.3 0.4 248 15 235 255 8.2 0 8.3 8.3 09/24/2005 19:30:00 1.7 0.8 4.2 0.4 1.4 0.9 3.8 0.4 0.9 0.7 3.4 0.4 224 9 204 255 8.1 0 8.3 8 09/24/2005 19:40:00 3.6 1.4 8 0.7 3.4 1.5 8 0.4 2.8 1.4 6.5 0.4 265 35 308 255 8.6 0.3 9 8.3 09/24/2005 19:50:00 2.2 0.7 5.3 0.7 1.8 0.7 5.3 0.4 1.3 0.7 3.8 0.4 288 19 297 255 8.9 0 9 8.8 09/24/2005 20:00:00 1.8 0.6 3 0.7 1.4 0.6 2.6 0.4 1.1 0.6 3 0.4 337 22 330 255 8.5 0.1 9 8.5 09/24/2005 20:10:00 0.8 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.2 1.1 0.4 309 69 358 255 8.3 0 8.5 8.3 09/24/2005 20:20:00 1.5 0.8 3 0.4 1.3 0.7 2.6 0.4 1.4 0.6 2.6 0.4 216 69 220 255 8.1 0 8.3 8 09/24/2005 20:30:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 149 13 142 255 8.3 0 8.3 8.3 09/24/2005 20:40:00 1.6 0.4 2.6 0.4 1.3 0.4 2.3 0.4 1.2 0.4 2.6 0.4 155 15 138 255 8.1 0 8.3 8 09/24/2005 20:50:00 1.9 0.6 3 0.4 1.7 0.7 3 0.4 1.6 0.6 3 0.4 129 28 150 255 8.1 0 8.3 8 09/24/2005 21:00:00 2.1 0.5 3 0.7 2 0.6 3 0.4 1.7 0.6 3 0.7 136 15 140 255 8 0 8.3 8 09/24/2005 21:10:00 3.2 1 5.3 1.1 3.1 1 4.9 1.5 2.6 0.8 4.2 0.7 133 10 125 255 8 0 8.3 7.8 09/24/2005 21:20:00 1.1 0.9 3.8 0.4 0.9 0.8 3.8 0.4 0.9 0.6 3.4 0.4 90 69 121 255 8 0 8.3 7.8 09/24/2005 21:30:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.1 2.5 0.5 3.8 1.1 138 10 139 255 8 0 8 7.8 09/24/2005 21:40:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 1.9 0.4 3 0.7 137 10 119 255 7.9 0 8 7.8 09/24/2005 21:50:00 2.2 0.8 3.4 0.4 2.1 0.8 3.4 0.4 1.7 0.7 3.4 0.4 136 35 134 255 7.8 0 7.8 7.8 09/24/2005 22:00:00 2.5 0.7 3.8 0.4 2.4 0.8 4.2 0.4 1.8 0.7 3.8 0.4 136 22 126 255 7.8 0 7.8 7.5 09/24/2005 22:10:00 1.5 1 3.8 0.4 1.3 1 3.8 0.4 1.3 0.7 3.4 0.4 93 43 110 255 7.8 0 7.8 7.5 09/24/2005 22:20:00 1.3 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 94 14 90 255 7.7 0 7.8 7.5 09/24/2005 22:30:00 0.9 0.6 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 120 12 90 255 7.5 0 7.8 7.3 09/24/2005 22:40:00 1.4 0.8 3.4 0.4 1.1 0.8 3.4 0.4 0.8 0.7 2.6 0.4 124 14 119 255 7.3 0 7.5 7.3 09/24/2005 22:50:00 2.2 0.5 3.8 0.7 2 0.6 3.4 0.4 1.6 0.5 3 0.4 126 11 115 255 7.1 0 7.3 7 09/24/2005 23:00:00 1.9 0.5 3 0.4 1.8 0.5 3 0.4 1.3 0.5 2.3 0.4 120 13 144 255 7 0 7.3 7 09/24/2005 23:10:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 0.9 0.6 2.6 0.4 123 16 131 255 6.8 0 7 6.7 09/24/2005 23:20:00 2.7 0.5 3.8 1.5 2.6 0.5 3.4 1.5 1.9 0.5 3 0.4 138 7 144 255 6.9 0 7 6.7 09/24/2005 23:30:00 2.3 0.6 3.4 0.7 2.2 0.7 3.4 0.4 1.8 0.6 3.4 0.4 148 11 141 255 7.1 0 7.3 7 09/24/2005 23:40:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.4 1.9 0.4 66 36 15 255 7.1 0 7.3 7 09/24/2005 23:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 35 27 88 255 7.1 0 7.3 7 09/25/2005 00:00:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 60 39 98 255 7.1 0 7.3 7 09/25/2005 00:10:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 109 6 113 255 7.1 0 7.3 7 09/25/2005 00:20:00 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 113 0 113 255 7 0 7.3 7 09/25/2005 00:30:00 0.9 0.4 1.5 0.4 0.7 0.3 1.1 0.4 0.7 0.4 1.5 0.4 101 10 113 255 6.9 0 7 7 09/25/2005 00:40:00 1.3 0.7 3 0.4 1 0.8 3 0.4 0.9 0.5 2.3 0.4 85 9 95 255 6.9 0 7 7 09/25/2005 00:50:00 1.2 0.7 3 0.4 1 0.7 3 0.4 0.7 0.4 1.9 0.4 90 7 86 255 6.9 0 7 7 09/25/2005 01:00:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 1.1 0.4 1.9 0.4 109 4 106 255 6.9 0 7 6.7 09/25/2005 01:10:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.1 1.5 0.3 2.3 0.7 102 4 101 255 6.8 0 7 6.7 09/25/2005 01:20:00 2.1 0.4 3 0.7 2 0.4 3 0.7 1.1 0.5 2.3 0.4 109 9 99 255 6.7 0 7 6.7 09/25/2005 01:30:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 1.4 0.4 2.3 0.4 109 6 117 255 6.7 0 6.7 6.7 09/25/2005 01:40:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 1.1 0.4 2.3 0.4 111 9 93 255 6.7 0 6.7 6.7 09/25/2005 01:50:00 1.7 0.5 2.6 0.7 1.4 0.5 2.6 0.4 0.8 0.5 1.9 0.4 125 6 124 255 6.6 0 6.7 6.5 09/25/2005 02:00:00 1.4 0.4 2.6 0.7 1.2 0.4 2.3 0.4 0.5 0.3 1.9 0.4 117 5 122 255 6.6 0 6.7 6.5 09/25/2005 02:10:00 1.8 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.8 0.4 1.9 0.4 120 5 129 255 6.5 0 6.7 6.2 09/25/2005 02:20:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 71 27 100 255 6.4 0 6.7 6.2 09/25/2005 02:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 65 255 6.4 0 6.5 6.2 09/25/2005 02:40:00 1.3 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 65 0 65 255 6.3 0 6.5 6.2 09/25/2005 02:50:00 1.8 0.4 2.6 0.7 1.6 0.4 2.3 0.4 0.9 0.4 1.9 0.4 82 9 83 255 6.4 0 6.5 6.2 09/25/2005 03:00:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 100 20 88 255 6.2 0 6.5 6.2 09/25/2005 03:10:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 110 22 131 255 6.2 0 6.5 6.2 09/25/2005 03:20:00 1 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 87 0 87 255 6.4 0 6.5 6.2 09/25/2005 03:30:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 104 9 109 255 6.3 0 6.5 6.2 09/25/2005 03:40:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 96 20 109 255 6.4 0 6.5 6.2 09/25/2005 03:50:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 66 0 66 255 6.4 0 6.5 6.2 09/25/2005 04:00:00 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 78 11 87 255 6.4 0 6.5 6.2 09/25/2005 04:10:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 88 3 97 255 6.4 0 6.7 6.2 09/25/2005 04:20:00 1.4 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.5 0.2 1.5 0.4 100 5 106 255 6.5 0 6.7 6.5 09/25/2005 04:30:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 117 13 101 255 6.5 0 6.7 6.5 09/25/2005 04:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 105 6 105 255 6.5 0 6.7 6.5 09/25/2005 04:50:00 1.1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 93 8 97 255 6.5 0 6.7 6.5 09/25/2005 05:00:00 1.2 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 115 15 104 255 6.5 0 6.7 6.5 09/25/2005 05:10:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 105 0 105 255 6.5 0 6.7 6.5 09/25/2005 05:20:00 1.4 0.4 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 106 2 115 255 6.5 0 6.7 6.5 09/25/2005 05:30:00 2.4 0.6 3.8 1.1 2.2 0.7 3.8 0.4 1.2 0.6 2.3 0.4 111 11 94 255 6.5 0 6.7 6.5 09/25/2005 05:40:00 2.6 0.8 4.6 0.4 2.3 0.9 4.2 0.4 1.7 0.7 3.8 0.4 121 14 127 255 6.6 0 6.7 6.5 09/25/2005 05:50:00 3.2 0.5 4.2 1.9 2.9 0.5 4.2 1.5 2.2 0.6 4.2 0.7 115 10 104 255 7 0 7.3 6.7 09/25/2005 06:00:00 2.9 0.5 4.2 1.9 2.6 0.6 4.2 1.1 2 0.5 3.4 0.7 118 12 123 255 7.3 0 7.5 7.3 09/25/2005 06:10:00 2.8 0.6 4.6 1.5 2.6 0.7 4.6 0.7 2 0.6 3.8 0.7 122 12 121 255 7.3 0 7.5 7.3 09/25/2005 06:20:00 3 0.6 4.6 1.1 2.7 0.6 4.2 1.1 2.1 0.6 3.8 0.7 126 12 99 255 7.4 0 7.5 7.3 09/25/2005 06:30:00 2.9 0.6 4.2 1.5 2.6 0.6 3.8 1.1 2 0.5 3.4 0.7 125 12 95 255 7.4 0 7.5 7.3 09/25/2005 06:40:00 2.9 0.7 4.9 1.5 2.7 0.7 4.6 0.7 2.1 0.6 3.8 0.7 117 11 106 255 7.5 0 7.5 7.5 09/25/2005 06:50:00 2.7 0.6 4.2 1.1 2.5 0.6 3.8 1.1 2 0.5 3.4 1.1 120 12 121 255 7.5 0 7.8 7.3 09/25/2005 07:00:00 2.8 0.6 4.2 1.1 2.5 0.7 3.8 0.4 2 0.7 3.4 0.4 122 12 121 255 7.4 0 7.5 7.3 09/25/2005 07:10:00 2.5 0.8 4.6 0.4 2.1 0.9 4.2 0.4 1.6 0.7 3 0.4 128 16 129 255 7.4 0 7.5 7.3 09/25/2005 07:20:00 1.5 0.7 3 0.4 1.2 0.6 3 0.4 0.9 0.4 1.9 0.4 133 28 108 255 7.4 0 7.5 7.3 09/25/2005 07:30:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.5 0.5 2.6 0.4 127 15 133 255 7.6 0 7.8 7.5 09/25/2005 07:40:00 2.6 0.6 3.8 1.1 2.3 0.7 3.4 0.4 1.8 0.6 3 0.7 131 10 118 255 7.8 0 7.8 7.5 09/25/2005 07:50:00 2.3 0.5 3.4 1.1 2 0.5 3.4 0.7 1.7 0.6 3 0.4 143 14 132 255 7.8 0 8 7.8 09/25/2005 08:00:00 1.6 0.7 3.4 0.4 1.1 0.7 3 0.4 0.9 0.6 2.6 0.4 154 17 130 255 7.8 0 7.8 7.8 09/25/2005 08:10:00 0.8 0.5 2.6 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 162 10 162 255 7.8 0 7.8 7.8 09/25/2005 08:20:00 1.5 0.6 2.6 0.4 1.1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 135 7 145 255 7.9 0 8 7.8 09/25/2005 08:30:00 1.3 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 123 17 112 255 8 0 8 7.8 09/25/2005 08:40:00 1.8 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1 0.4 2.3 0.4 138 10 129 255 8.1 0 8.3 8 09/25/2005 08:50:00 1.5 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 119 15 134 255 8.5 0.1 8.8 8.3 09/25/2005 09:00:00 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 116 20 119 255 8.9 0 9 8.8 09/25/2005 09:10:00 1.3 0.6 2.6 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 125 19 129 255 9 0 9.3 9 09/25/2005 09:20:00 1.9 0.5 3.4 0.4 1.5 0.5 3 0.4 1.5 0.5 2.6 0.4 110 9 115 255 9.3 0 9.6 9 09/25/2005 09:30:00 1.8 0.6 3 0.4 1.4 0.6 3 0.4 1.4 0.5 3 0.4 115 17 108 255 9.6 0 9.8 9.6 09/25/2005 09:40:00 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 1.2 0.6 2.3 0.4 112 22 89 255 10 0 10.1 9.6 09/25/2005 09:50:00 1.8 0.6 3 0.4 1.4 0.6 3 0.4 1.5 0.6 2.6 0.4 105 15 112 255 10.1 0 10.3 10.1 09/25/2005 10:00:00 2 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.6 0.8 3.4 0.4 99 11 85 255 10.3 0 10.6 10.1 09/25/2005 10:10:00 2.4 0.5 3.4 1.1 2.1 0.5 3 0.7 2.1 0.6 3.4 0.4 98 12 116 255 10.4 0 10.6 10.3 09/25/2005 10:20:00 2 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.9 0.6 3.4 0.4 108 11 102 255 10.5 0 10.6 10.6 09/25/2005 10:30:00 1.7 0.7 3 0.4 1.3 0.7 3 0.4 1.3 0.6 3 0.4 124 17 140 255 10.6 0 10.6 10.6 09/25/2005 10:40:00 1.5 0.4 2.6 0.4 1 0.5 1.9 0.4 1.4 0.4 2.3 0.4 111 17 97 255 10.7 0 10.9 10.6 09/25/2005 10:50:00 1.1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 111 11 124 255 10.8 0 10.9 10.6 09/25/2005 11:00:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 130 13 131 255 10.9 0 11.1 10.9 09/25/2005 11:10:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 166 29 175 255 10.9 0 11.1 10.9 09/25/2005 11:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 150 13 144 255 11 0 11.1 10.9 09/25/2005 11:30:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 160 29 131 255 11.1 0 11.1 10.9 09/25/2005 11:40:00 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 199 17 198 255 11.5 0.1 11.7 11.1 09/25/2005 11:50:00 1.2 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 201 41 158 255 11.8 0 11.9 11.7 09/25/2005 12:00:00 1.2 0.7 3 0.4 0.8 0.6 3 0.4 0.8 0.6 2.6 0.4 239 30 238 255 12 0 12.2 11.9 09/25/2005 12:10:00 1 0.7 3 0.4 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 236 26 196 255 12.1 0 12.2 11.9 09/25/2005 12:20:00 1.3 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.5 2.3 0.4 249 26 238 255 11.7 0 11.9 11.7 09/25/2005 12:30:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.6 0.4 2.6 0.4 237 24 277 255 11.7 0 11.7 11.4 09/25/2005 12:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 250 13 225 255 11.7 0 11.9 11.4 09/25/2005 12:50:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 58 94 97 255 11.8 0 11.9 11.7 09/25/2005 13:00:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 27 23 21 255 11.8 0 11.9 11.7 09/25/2005 13:10:00 0.7 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 29 21 12 255 12.2 0.1 12.5 11.9 09/25/2005 13:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.9 0.4 37 107 295 255 12.4 0 12.5 12.2 09/25/2005 13:30:00 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 1 0.6 2.3 0.4 299 27 305 255 12.3 0 12.5 12.2 09/25/2005 13:40:00 0.6 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 292 45 334 255 12.5 0 12.7 12.2 09/25/2005 13:50:00 1.5 0.8 3.4 0.4 1.2 0.7 3 0.4 1 0.5 2.3 0.4 260 36 257 255 12.9 0.3 13.8 12.7 09/25/2005 14:00:00 1.1 0.7 3 0.4 0.8 0.6 3.4 0.4 0.8 0.6 2.6 0.4 267 24 323 255 13.7 0.1 13.8 13.3 09/25/2005 14:10:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 2 72 318 255 14.1 0.2 14.6 13.5 09/25/2005 14:20:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 14 17 10 255 13.7 0.5 14.6 12.7 09/25/2005 14:30:00 1 0.8 2.6 0.4 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 20 8 6 255 12.5 0.1 13 12.2 09/25/2005 14:40:00 2.1 0.7 3.8 0.4 1.7 0.8 3.8 0.4 1.6 0.6 3.4 0.4 7 13 359 255 12.3 0 12.7 12.2 09/25/2005 14:50:00 2.4 0.4 3.4 1.1 2.1 0.5 3 0.7 1.7 0.6 3 0.4 5 9 19 255 12.5 0 13 12.5 09/25/2005 15:00:00 2.4 0.4 3.4 1.5 2.1 0.4 3 1.1 2 0.5 3 0.7 17 9 356 255 12.7 0 13 12.5 09/25/2005 15:10:00 1.4 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 2 7 14 255 12.7 0 12.7 12.5 09/25/2005 15:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 83 26 62 255 12.5 0.1 12.7 12.5 09/25/2005 15:30:00 1.4 0.4 2.6 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 16 19 23 255 12.4 0 12.5 12.2 09/25/2005 15:40:00 1.6 0.4 2.6 0.7 1.2 0.5 2.3 0.4 1.3 0.4 2.6 0.4 41 16 45 255 12.5 0 12.7 12.5 09/25/2005 15:50:00 1.9 0.4 3 1.1 1.6 0.5 3 0.4 1.5 0.5 3 0.4 18 11 8 255 12.6 0 12.7 12.5 09/25/2005 16:00:00 2.2 0.5 3.4 1.1 1.9 0.5 3.4 0.7 1.6 0.7 3.4 0.4 23 17 26 255 12.7 0 12.7 12.5 09/25/2005 16:10:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.9 27 9 19 255 12.9 0 13 12.7 09/25/2005 16:20:00 2.2 0.5 3.4 0.7 1.9 0.5 3 0.7 1.8 0.5 3 0.4 47 22 79 255 12.5 0 12.7 12.2 09/25/2005 16:30:00 2.9 0.5 4.6 1.5 2.7 0.6 3.8 1.1 2.6 0.5 3.8 1.5 38 13 32 255 12.3 0 12.2 12.2 09/25/2005 16:40:00 2.8 0.7 4.2 0.4 2.6 0.8 4.2 0.4 2.1 0.7 4.2 0.4 37 28 356 255 12 0 12.2 11.9 09/25/2005 16:50:00 2.6 0.6 4.2 0.4 2.3 0.6 4.2 0.4 2.1 0.7 3.8 0.4 43 13 25 255 12 0 12.2 11.9 09/25/2005 17:00:00 2.9 0.5 4.2 1.5 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 51 17 62 255 11.9 0.1 12.2 11.7 09/25/2005 17:10:00 2.9 0.6 4.2 1.5 2.7 0.6 4.2 1.1 2.4 0.6 3.8 0.7 69 12 90 255 11.4 0.1 11.7 11.1 09/25/2005 17:20:00 2.6 0.6 4.2 1.5 2.3 0.7 3.8 0.7 2 0.6 3.8 0.7 72 13 62 255 11.2 0 11.4 11.1 09/25/2005 17:30:00 2.5 0.6 3.8 1.1 2.2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 108 13 113 255 11.1 0 11.4 11.1 09/25/2005 17:40:00 1.7 0.5 3 0.4 1.2 0.6 3 0.4 1 0.5 3 0.4 92 19 115 255 11 0 11.1 10.9 09/25/2005 17:50:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 0.7 1.9 0.5 3 0.7 85 11 89 255 10.8 0 11.1 10.6 09/25/2005 18:00:00 2.8 0.5 4.2 1.9 2.6 0.5 3.8 1.1 2.1 0.5 3.4 0.7 88 9 83 255 10.6 0 10.9 10.6 09/25/2005 18:10:00 3.3 0.7 5.3 1.5 3.2 0.8 5.3 1.1 2.6 0.8 4.6 0.7 63 13 75 255 10.6 0 10.6 10.6 09/25/2005 18:20:00 3.4 0.5 4.6 1.9 3.2 0.5 4.6 1.9 2.8 0.6 4.2 1.1 76 9 83 255 10.6 0 10.6 10.6 09/25/2005 18:30:00 3.2 0.7 4.9 1.9 3 0.7 4.6 1.5 2.4 0.7 4.6 0.7 85 11 106 255 10.4 0 10.6 10.3 09/25/2005 18:40:00 3.7 0.6 5.7 2.3 3.6 0.7 6.1 1.9 2.8 0.7 4.2 1.1 44 20 56 255 10.2 0 10.3 10.1 09/25/2005 18:50:00 3.2 1 5.7 1.1 3 1 5.3 1.1 2.4 1 4.6 0.7 21 17 48 255 10 0 10.3 9.8 09/25/2005 19:00:00 3.5 0.7 5.7 1.5 3.4 0.8 5.7 1.1 2.9 0.8 4.9 0.7 36 12 18 255 9.9 0 10.1 9.8 09/25/2005 19:10:00 2.5 0.5 3.4 1.5 2.3 0.5 3.4 1.1 1.9 0.5 3 0.7 61 13 37 255 9.6 0 9.8 9.6 09/25/2005 19:20:00 2.2 0.4 3.4 1.5 1.9 0.5 3.4 1.1 1.6 0.5 3 0.4 89 14 102 255 9.4 0 9.6 9 09/25/2005 19:30:00 2.9 0.6 4.6 1.5 2.7 0.7 4.6 1.1 2.2 0.7 4.2 0.4 72 13 68 255 9.1 0 9.3 9 09/25/2005 19:40:00 1.7 0.7 3 0.4 1.4 0.7 3 0.4 1.1 0.6 2.6 0.4 86 15 76 255 9.4 0 9.6 9.3 09/25/2005 19:50:00 1.9 1 3.4 0.4 1.7 1 3 0.4 1.5 0.6 2.6 0.4 192 43 222 255 8.9 0.1 9.3 8.5 09/25/2005 20:00:00 4.1 0.8 5.7 1.5 3.9 0.8 5.7 1.5 2.8 0.8 4.9 0.7 215 12 223 255 8.4 0 8.5 8.5 09/25/2005 20:10:00 3 0.6 4.6 1.5 2.9 0.5 4.2 1.5 2.2 0.5 3.4 1.1 199 12 208 255 8.4 0 8.5 8.5 09/25/2005 20:20:00 2.3 0.5 3.8 1.1 2.3 0.6 3.8 0.7 1.9 0.5 3 0.4 184 14 184 255 8.4 0 8.5 8.5 09/25/2005 20:30:00 2.9 0.7 4.9 1.5 2.9 0.6 4.6 1.5 2.3 0.7 4.6 0.7 161 11 147 255 8.3 0 8.5 8.3 09/25/2005 20:40:00 3.7 0.8 5.7 1.9 3.6 0.8 5.3 1.5 2.9 0.9 4.9 1.1 162 14 162 255 8.4 0 8.5 8.3 09/25/2005 20:50:00 3.3 0.7 4.6 1.5 3.4 0.6 4.6 1.1 2.8 0.6 4.6 1.5 169 13 160 255 8.3 0 8.5 8.3 09/25/2005 21:00:00 2.9 0.7 4.9 1.5 2.8 0.7 4.6 0.7 2.3 0.7 4.2 0.7 161 15 153 255 8.3 0 8.5 8.3 09/25/2005 21:10:00 3 0.7 4.6 1.1 2.8 0.8 4.6 0.4 2.4 0.7 4.6 0.7 145 17 145 255 8.3 0 8.3 8.3 09/25/2005 21:20:00 2.8 0.8 4.9 1.1 2.7 0.8 4.9 1.1 2.3 0.7 4.2 0.7 163 22 116 255 8.1 0 8.3 8 09/25/2005 21:30:00 3.5 0.7 5.7 1.9 3.4 0.7 5.7 1.5 2.8 0.6 4.6 1.1 133 17 140 255 8 0 8.3 7.8 09/25/2005 21:40:00 3.2 0.6 4.9 1.9 2.9 0.6 4.6 1.5 2.5 0.7 4.9 0.7 149 15 154 255 7.8 0 8 7.8 09/25/2005 21:50:00 2.6 0.8 4.6 0.7 2.4 0.9 4.6 0.4 1.8 0.8 3.8 0.4 135 18 145 255 7.6 0 7.8 7.5 09/25/2005 22:00:00 2.6 0.7 4.6 1.1 2.3 0.7 4.2 0.4 1.8 0.6 3.4 0.4 113 21 130 255 7.6 0 7.8 7.5 09/25/2005 22:10:00 3 0.8 4.9 1.1 2.8 0.8 4.6 0.7 2.3 0.9 4.6 0.4 75 27 99 255 7.6 0 7.8 7.5 09/25/2005 22:20:00 3.3 0.7 4.9 1.5 3.1 0.7 5.3 1.1 2.5 0.8 4.6 0.4 103 15 101 255 7.6 0 7.8 7.5 09/25/2005 22:30:00 2.4 0.6 4.2 1.1 2 0.7 4.2 0.4 1.7 0.7 3.8 0.4 112 19 135 255 7.6 0 7.8 7.5 09/25/2005 22:40:00 1.9 0.7 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.7 3 0.4 114 15 133 255 7.5 0 7.5 7.3 09/25/2005 22:50:00 3.2 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2.4 0.6 3.8 0.7 133 10 127 255 7.3 0 7.5 7.3 09/25/2005 23:00:00 3 0.6 4.6 1.5 2.8 0.6 4.6 1.1 2.3 0.5 3.8 1.1 127 12 127 255 7.4 0 7.5 7.3 09/25/2005 23:10:00 3 0.5 4.6 1.9 2.7 0.5 4.2 1.1 2.3 0.5 3.8 0.7 135 10 134 255 7.4 0 7.5 7.3 09/25/2005 23:20:00 3.2 0.8 5.3 0.7 3 0.8 4.9 0.7 2.3 0.8 4.2 0.7 122 11 115 255 7.4 0 7.5 7.3 09/25/2005 23:30:00 3.1 0.6 4.9 1.9 2.9 0.6 4.6 1.5 2.4 0.5 3.8 1.1 133 14 105 255 7.4 0 7.5 7.3 09/25/2005 23:40:00 3.6 0.6 5.3 2.3 3.4 0.6 4.9 2.3 2.8 0.6 4.6 1.5 128 11 127 255 7.4 0 7.5 7.5 09/25/2005 23:50:00 3.5 0.7 5.3 1.9 3.2 0.7 4.9 1.5 2.6 0.5 3.8 1.5 130 13 122 255 7.4 0 7.5 7.5 09/26/2005 00:00:00 3.4 0.6 4.9 1.5 3.2 0.6 4.6 1.5 2.5 0.6 4.2 1.1 128 12 146 255 7.4 0 7.5 7.5 09/26/2005 00:10:00 3.3 0.6 5.3 1.9 3.1 0.6 4.6 1.9 2.4 0.7 4.2 0.4 123 12 121 255 7.5 0 7.5 7.5 09/26/2005 00:20:00 2.7 0.5 4.2 1.1 2.4 0.6 4.2 1.1 1.6 0.7 4.2 0.4 117 14 127 255 7.6 0 7.8 7.5 09/26/2005 00:30:00 3.1 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2.2 0.7 3.8 0.7 117 13 115 255 7.6 0 7.5 7.5 09/26/2005 00:40:00 3.2 0.6 4.6 1.9 3 0.6 4.6 1.5 2.3 0.6 3.8 0.7 120 13 111 255 7.6 0 7.5 7.5 09/26/2005 00:50:00 3.4 0.7 4.9 1.9 3.1 0.8 4.9 1.5 2.3 0.6 3.8 0.4 121 15 130 255 7.6 0 7.8 7.5 09/26/2005 01:00:00 2.8 0.6 4.6 1.5 2.5 0.6 4.6 0.7 2 0.6 3.4 0.4 108 16 129 255 7.6 0 7.8 7.5 09/26/2005 01:10:00 3.3 0.7 5.3 1.5 3 0.8 4.9 1.1 2.3 0.7 4.2 0.7 117 17 105 255 7.5 0 7.5 7.5 09/26/2005 01:20:00 3.5 0.8 6.1 1.9 3.2 0.9 5.7 1.1 2.7 0.8 4.9 1.1 109 13 117 255 7.5 0 7.5 7.5 09/26/2005 01:30:00 2.9 0.6 4.9 1.5 2.6 0.7 4.2 0.7 2.1 0.7 3.8 0.4 111 13 121 255 7.6 0 7.5 7.5 09/26/2005 01:40:00 3.1 0.6 4.6 1.5 2.9 0.5 4.2 1.5 2.4 0.6 4.2 1.1 106 13 106 255 7.6 0 7.8 7.5 09/26/2005 01:50:00 3.2 0.7 4.9 1.1 3 0.7 4.9 0.7 2.4 0.8 4.2 0.4 105 12 105 255 7.5 0 7.5 7.5 09/26/2005 02:00:00 3.1 0.5 4.2 1.9 2.8 0.5 4.2 1.5 2 0.5 3 0.4 106 11 96 255 7.4 0 7.5 7.3 09/26/2005 02:10:00 3 0.6 4.6 1.5 2.7 0.6 4.2 1.1 2.1 0.6 4.2 0.4 100 11 94 255 7.4 0 7.5 7.3 09/26/2005 02:20:00 2.9 0.5 4.2 1.9 2.7 0.5 3.8 1.5 2 0.7 3.8 0.4 94 10 87 255 7.3 0 7.5 7.3 09/26/2005 02:30:00 2.4 0.4 3.4 1.1 2.1 0.5 3.4 0.4 1.5 0.6 3 0.4 97 11 107 255 7.3 0 7.3 7.3 09/26/2005 02:40:00 2.1 0.4 3 1.1 1.8 0.5 3 0.4 1 0.5 2.3 0.4 94 11 93 255 7.1 0.1 7.3 6.7 09/26/2005 02:50:00 1.4 0.4 2.6 0.7 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 94 8 83 255 6.5 0.2 7 6.2 09/26/2005 03:00:00 1.2 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 83 10 90 255 5.9 0.1 6.2 5.7 09/26/2005 03:10:00 1.6 0.3 2.3 1.1 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 62 0 62 255 5.6 0 6 5.5 09/26/2005 03:20:00 1.9 0.3 2.6 1.1 1.5 0.3 2.3 0.7 0.5 0.3 1.5 0.4 65 6 68 255 5.2 0.1 5.5 5 09/26/2005 03:30:00 2.1 0.3 3 1.1 1.8 0.4 3 0.7 1 0.4 2.3 0.4 69 2 66 255 5 0 5 4.8 09/26/2005 03:40:00 3.1 0.5 4.2 1.9 2.9 0.6 4.2 1.1 2.1 0.4 3 1.1 85 10 80 255 4.7 0 4.8 4.5 09/26/2005 03:50:00 3.3 0.5 4.6 1.5 3.1 0.5 4.2 1.1 2.2 0.5 3.8 0.7 103 11 100 255 4.7 0 4.8 4.5 09/26/2005 04:00:00 3.2 0.4 4.2 1.9 3 0.4 3.8 1.9 2.2 0.5 3.4 1.1 97 8 95 255 4.6 0 4.8 4.5 09/26/2005 04:10:00 3.2 0.4 4.2 2.3 3 0.4 4.2 2.3 2.1 0.4 3 0.7 95 6 100 255 4.4 0 4.8 4.3 09/26/2005 04:20:00 3.6 0.5 4.6 2.3 3.4 0.5 4.9 1.9 2.5 0.7 4.6 0.4 104 11 107 255 4.4 0 4.8 4.3 09/26/2005 04:30:00 3.2 0.5 4.6 1.5 2.9 0.6 4.2 1.1 1.9 0.7 3.4 0.4 108 10 113 255 5 0 5 4.8 09/26/2005 04:40:00 3.3 0.5 4.2 1.9 3.1 0.5 4.6 1.5 2.2 0.6 3.4 0.7 108 11 100 255 5.1 0 5.2 4.8 09/26/2005 04:50:00 3.6 0.6 4.9 1.5 3.4 0.6 4.9 1.5 2.6 0.7 4.2 0.7 116 12 105 255 4.9 0.1 5.5 4.8 09/26/2005 05:00:00 3.4 0.6 4.9 1.5 3.2 0.6 4.9 1.5 2.1 0.6 3.4 0.4 112 13 124 255 5.2 0.1 5.5 5 09/26/2005 05:10:00 3.4 0.6 5.3 1.9 3.2 0.6 4.9 1.5 2.3 0.6 4.2 0.4 112 13 85 255 5.1 0 5.5 5 09/26/2005 05:20:00 3.8 0.6 5.3 2.3 3.6 0.6 5.3 1.9 2.7 0.7 4.6 1.1 107 12 104 255 5.4 0 5.5 5 09/26/2005 05:30:00 3.6 0.8 5.3 1.9 3.4 0.9 5.3 1.1 2.6 0.7 4.9 0.4 110 13 105 255 5.6 0 6 5.5 09/26/2005 05:40:00 3.1 0.6 4.6 1.9 2.9 0.6 4.9 1.5 2 0.6 4.2 0.4 117 17 122 255 5.6 0 6 5.2 09/26/2005 05:50:00 3.3 0.6 4.9 1.9 3.1 0.6 4.9 1.5 2.3 0.6 4.2 1.1 120 13 118 255 5.6 0 6 5.5 09/26/2005 06:00:00 4.2 1 6.1 1.9 4 1 6.1 1.5 3.2 0.9 5.7 0.7 119 15 119 255 5.7 0 6.2 5.7 09/26/2005 06:10:00 3.9 0.7 6.1 1.9 3.7 0.7 5.3 1.5 3 0.7 4.9 1.5 113 14 112 255 5.7 0 6.2 5.7 09/26/2005 06:20:00 4.1 0.7 6.1 2.3 3.8 0.7 5.7 1.9 3 0.8 4.9 1.1 111 13 93 255 5.7 0 6 5.7 09/26/2005 06:30:00 4.4 0.7 6.1 2.6 4.1 0.7 5.7 2.6 3.1 0.7 5.3 1.5 109 11 108 255 5.6 0 5.7 5.5 09/26/2005 06:40:00 4.6 0.7 6.5 2.6 4.4 0.8 6.1 2.6 3.3 0.9 5.3 1.1 110 11 124 255 5.7 0.1 6.2 5.5 09/26/2005 06:50:00 4.5 0.7 6.1 2.3 4.3 0.7 6.1 2.3 3.3 0.8 5.7 1.1 109 12 121 255 5.7 0 6.2 5.7 09/26/2005 07:00:00 4.1 0.9 6.1 2.3 4 0.9 5.7 1.9 3 0.9 5.3 1.1 112 15 106 255 5.7 0 6 5.7 09/26/2005 07:10:00 4.2 0.6 5.7 2.3 4 0.7 5.7 1.9 3.1 0.7 4.9 1.1 112 10 101 255 5.7 0 5.7 5.7 09/26/2005 07:20:00 4.5 0.6 6.1 2.6 4.4 0.6 6.1 2.3 3.4 0.8 5.3 1.5 110 12 106 255 5.9 0 6.5 5.7 09/26/2005 07:30:00 4.9 0.8 7.2 2.6 4.8 0.8 6.5 2.6 3.8 0.8 6.1 1.5 113 13 115 255 6.2 0.1 6.7 6 09/26/2005 07:40:00 4.8 0.8 6.5 2.6 4.6 0.8 6.5 2.6 3.6 1 5.7 1.1 110 12 115 255 6.4 0 6.7 6.2 09/26/2005 07:50:00 4.7 0.8 6.8 2.3 4.5 0.9 6.8 2.3 3.6 0.8 5.7 1.5 109 10 106 255 6.7 0 6.7 6.5 09/26/2005 08:00:00 4.3 0.8 6.1 2.6 4.1 0.8 6.1 1.9 3.4 0.8 5.3 1.1 109 15 117 255 6.7 0 7 6.7 09/26/2005 08:10:00 4.6 0.8 6.8 2.6 4.4 0.9 6.8 2.3 3.6 1 6.1 1.5 112 12 109 255 6.8 0 7 6.7 09/26/2005 08:20:00 4.3 1.1 6.5 1.5 4.1 1.1 6.5 1.1 3.3 1.1 6.1 0.4 116 17 116 255 7.2 0 7.3 7 09/26/2005 08:30:00 4.1 1 6.8 1.5 4 1 6.5 1.5 3 1 6.1 1.1 114 17 105 255 7.4 0 7.5 7.3 09/26/2005 08:40:00 4.2 1 6.8 2.3 4 1 6.8 1.9 3.2 1 5.3 0.7 106 16 87 255 7.8 0.1 8 7.5 09/26/2005 08:50:00 3.7 0.7 5.3 1.9 3.5 0.8 5.3 1.9 2.7 0.8 4.9 0.7 109 17 114 255 7.9 0 8.3 7.8 09/26/2005 09:00:00 4.4 0.9 6.8 2.3 4.2 0.9 6.5 1.9 3.5 0.9 6.5 1.1 107 15 139 255 8 0 8.3 7.8 09/26/2005 09:10:00 4.4 0.8 6.5 2.6 4.2 0.8 6.5 2.3 3.5 0.9 5.7 1.5 110 16 126 255 8.5 0.1 9 8.3 09/26/2005 09:20:00 4.3 0.9 6.5 2.3 4.1 0.9 6.5 1.9 3.6 1 6.1 1.5 109 13 106 255 9.2 0 9.6 8.8 09/26/2005 09:30:00 4.4 1 6.8 1.9 4.2 1 6.8 1.5 3.6 1 6.1 1.1 108 14 113 255 9.6 0.1 10.1 9.3 09/26/2005 09:40:00 4 0.7 6.1 2.3 3.8 0.7 5.7 2.3 3.4 0.7 4.9 1.9 102 14 115 255 10.2 0 10.3 10.1 09/26/2005 09:50:00 4.1 0.8 5.7 1.9 3.9 0.9 5.7 1.5 3.5 1 5.7 1.1 104 13 96 255 10.6 0.2 10.9 10.3 09/26/2005 10:00:00 3.9 0.8 6.1 1.9 3.7 0.8 6.1 1.9 3.1 1 5.7 1.1 103 18 91 255 11.1 0 11.4 10.9 09/26/2005 10:10:00 3.3 0.7 4.9 0.7 3.1 0.7 4.9 0.7 2.6 0.8 4.6 0.7 96 16 95 255 11.3 0 11.7 11.1 09/26/2005 10:20:00 4.1 0.8 5.7 2.6 3.9 0.8 5.7 2.3 3.6 0.7 5.3 1.9 94 12 104 255 11.6 0 11.7 11.4 09/26/2005 10:30:00 4.3 1.1 7.6 2.3 4.1 1.1 6.8 1.9 3.6 1 6.5 1.5 98 15 116 255 11.9 0 12.2 11.7 09/26/2005 10:40:00 4.5 0.8 6.5 1.9 4.4 0.8 6.5 2.3 3.9 0.9 6.8 1.5 99 15 92 255 12 0 12.2 11.9 09/26/2005 10:50:00 3.5 1 5.7 1.5 3.4 1 6.1 1.1 2.9 1.1 5.7 0.4 98 20 111 255 12.5 0 12.7 12.2 09/26/2005 11:00:00 3.9 0.8 5.7 1.9 3.6 0.8 5.3 1.5 3.4 0.9 5.7 1.5 81 17 64 255 12.7 0 12.7 12.5 09/26/2005 11:10:00 3.1 0.8 5.3 1.1 2.8 0.9 5.7 0.4 2.6 0.8 4.9 0.7 85 21 66 255 13 0 13.3 12.7 09/26/2005 11:20:00 3 0.7 4.6 1.1 2.8 0.8 4.6 0.7 2.6 0.9 4.9 0.4 80 28 115 255 13.3 0 13.3 13.3 09/26/2005 11:30:00 3.2 0.8 4.9 1.1 2.9 0.8 4.9 0.4 2.9 0.9 5.3 0.4 85 20 80 255 13.6 0 13.8 13.3 09/26/2005 11:40:00 3.2 1 5.3 1.1 3 1 5.3 0.7 2.8 1 4.9 0.4 84 30 95 255 13.7 0 13.8 13.5 09/26/2005 11:50:00 3.3 1.2 6.1 0.7 3.1 1.3 6.1 0.4 2.7 1.3 6.1 0.4 76 22 96 255 13.8 0 13.8 13.5 09/26/2005 12:00:00 3.7 0.9 6.1 1.5 3.5 1 6.5 1.5 3.2 0.9 5.3 1.1 67 22 80 255 13.7 0 14.1 13.5 09/26/2005 12:10:00 4.7 1 7.2 1.5 4.5 1.1 7.2 1.5 4 1 6.5 1.5 60 20 70 255 13.8 0 14.1 13.5 09/26/2005 12:20:00 5.8 1 8 3.4 5.7 1 8 3.4 5.1 1 7.6 2.6 45 12 46 255 13.9 0 14.1 13.8 09/26/2005 12:30:00 4.4 1 7.6 1.5 4.4 1 7.2 1.5 3.9 1 6.8 1.1 48 22 19 255 14.3 0.2 15.2 13.8 09/26/2005 12:40:00 4.2 0.8 6.5 1.9 3.9 0.8 6.1 1.9 3.6 0.8 6.1 1.5 46 19 49 255 14.4 0 14.9 14.4 09/26/2005 12:50:00 5.3 1.2 7.6 2.3 5.2 1.2 7.6 1.9 4.7 1.3 7.6 1.5 49 17 58 255 14.1 0.1 14.9 13.8 09/26/2005 13:00:00 5 1.1 7.6 1.9 4.9 1.2 7.6 1.9 4.5 1.2 7.6 1.9 59 13 43 255 13.9 0 14.4 13.8 09/26/2005 13:10:00 4.8 1.2 7.6 1.5 4.6 1.2 7.6 1.9 3.9 1.2 7.2 1.1 57 19 19 255 14 0 14.1 13.8 09/26/2005 13:20:00 5.4 1 8 2.6 5.3 1 8.4 2.3 4.5 1.1 8 1.9 46 22 66 255 14.4 0.1 14.9 14.1 09/26/2005 13:30:00 6 1 9.1 3.8 5.8 1.1 9.1 3.4 5.1 1.2 8 2.6 46 15 42 255 14.6 0 14.9 14.4 09/26/2005 13:40:00 4.5 1 7.2 1.9 4.4 1 7.2 1.5 3.9 1.1 6.8 0.4 74 23 68 255 14.2 0 14.9 14.1 09/26/2005 13:50:00 4.5 1.3 8.8 1.5 4.4 1.3 8.4 1.1 3.9 1.3 8.4 1.1 52 20 60 255 14.3 0 14.9 14.1 09/26/2005 14:00:00 3.7 1 6.5 1.1 3.5 1 6.1 0.7 3.2 1.1 6.5 0.4 43 17 8 255 14.4 0.1 15.2 14.1 09/26/2005 14:10:00 5.2 1.2 8 2.3 5.2 1.2 8 2.3 4.5 1.1 8 1.9 29 17 35 255 14.7 0 15.2 14.6 09/26/2005 14:20:00 5 1.3 8.8 1.9 4.9 1.3 9.1 2.3 4.1 1.3 7.6 1.5 23 18 9 255 14.8 0 15.5 14.6 09/26/2005 14:30:00 4.5 0.8 6.8 2.6 4.5 0.8 6.8 2.6 3.9 1 7.2 1.9 30 17 16 255 15 0 15.5 14.9 09/26/2005 14:40:00 5.7 1.6 9.9 1.9 5.6 1.6 9.9 1.9 4.9 1.5 9.5 1.9 27 14 42 255 14.7 0.1 15.5 14.6 09/26/2005 14:50:00 5.1 1 8 3 4.9 1.1 7.6 2.6 3.9 1.2 7.6 1.1 20 17 22 255 14.5 0 14.9 14.1 09/26/2005 15:00:00 6.2 1.3 10.3 3.8 6.1 1.3 9.9 3.4 5.1 1.3 9.1 1.9 15 12 2 255 13.8 0.1 14.4 13.5 09/26/2005 15:10:00 4.9 1.2 7.6 2.3 4.9 1.2 7.6 2.3 4.1 1 6.8 1.9 19 15 14 255 13.6 0 14.1 13.5 09/26/2005 15:20:00 5.4 1.3 8.4 2.3 5.3 1.3 8.4 2.3 4.2 1.5 8.4 1.5 17 17 8 255 13.7 0 14.4 13.5 09/26/2005 15:30:00 5.7 1.4 9.9 3 5.6 1.4 9.5 3 4.6 1.3 8.4 2.3 19 11 26 255 13.9 0 14.6 13.5 09/26/2005 15:40:00 5.6 1.2 8.4 2.3 5.5 1.2 8.4 1.9 4.6 1.1 7.6 2.3 37 14 46 255 13.9 0 14.4 13.8 09/26/2005 15:50:00 6.4 1.3 9.9 3.4 6.4 1.3 9.9 3.8 5.2 1.5 9.5 2.3 25 15 13 255 13.7 0 14.1 13.5 09/26/2005 16:00:00 5.4 1.3 9.1 1.5 5.3 1.4 9.1 1.5 4.5 1.3 7.6 1.5 25 17 40 255 13.6 0 13.8 13.3 09/26/2005 16:10:00 7.2 1.5 10.7 3.8 7 1.5 10.7 3.8 6 1.5 9.9 2.6 29 17 20 255 13.3 0 13.5 13.3 09/26/2005 16:20:00 7.7 1.5 11.1 4.2 7.6 1.5 11.1 3.4 6.4 1.7 10.7 2.3 23 13 27 255 13.3 0 13.3 13.3 09/26/2005 16:30:00 7.4 1.3 11.5 4.6 7.4 1.2 11.5 4.2 6.1 1.5 9.9 3 25 13 19 255 13.3 0 13.3 13 09/26/2005 16:40:00 7.3 1.6 11.8 3.8 7.2 1.7 11.8 3.4 6.1 1.9 10.3 2.3 27 13 14 255 13.1 0 13.3 13 09/26/2005 16:50:00 7.2 1.2 10.3 4.2 7.2 1.2 10.7 4.2 5.7 1.4 9.9 2.6 21 13 10 255 12.9 0 13 12.7 09/26/2005 17:00:00 7.7 1.5 11.8 3.4 7.7 1.4 11.5 4.2 6.5 1.7 11.1 2.6 19 12 3 255 12.6 0 12.7 12.5 09/26/2005 17:10:00 7.4 1.3 10.3 3.8 7.3 1.4 10.3 3.4 6.5 1.5 10.7 3 27 11 15 255 12.4 0 12.5 12.2 09/26/2005 17:20:00 7 1.3 10.3 3 6.9 1.3 10.7 3.4 5.7 1.3 9.1 2.6 32 14 33 255 12.3 0 12.5 12.2 09/26/2005 17:30:00 6 1.2 9.5 3 6 1.2 9.5 2.6 4.9 1.3 8.4 1.1 38 15 39 255 12.2 0 12.2 11.9 09/26/2005 17:40:00 7.1 1.1 10.3 4.6 7.1 1.1 10.3 4.2 5.9 1.2 8.8 3 45 11 15 255 11.8 0 11.9 11.7 09/26/2005 17:50:00 7.2 1.1 10.3 4.2 7.2 1.1 10.3 4.2 6.1 1.2 9.1 3 29 12 19 255 11.7 0 11.9 11.7 09/26/2005 18:00:00 6.6 1.1 9.9 3.8 6.6 1.2 9.9 3.8 5.6 1.2 9.1 3 32 12 50 255 11.6 0 11.7 11.4 09/26/2005 18:10:00 7.2 1.2 11.1 4.2 7.2 1.2 11.5 4.2 6 1.3 10.3 2.6 33 12 50 255 11.3 0 11.4 11.1 09/26/2005 18:20:00 7 1.2 10.3 4.2 7 1.2 10.7 3.8 5.8 1.2 9.1 2.3 31 12 35 255 11 0 11.1 10.9 09/26/2005 18:30:00 8 1.3 11.1 4.6 8 1.3 11.5 4.6 6.8 1.4 10.7 3.8 21 9 16 255 10.7 0 10.9 10.6 09/26/2005 18:40:00 8.8 1.3 11.8 5.3 8.8 1.3 12.2 5.3 6.9 1.5 10.7 3 15 9 1 255 10.6 0 10.9 10.6 09/26/2005 18:50:00 7.9 1.5 12.2 4.9 7.9 1.5 11.8 4.9 6.4 1.5 10.3 3 14 9 23 255 10.5 0 10.6 10.3 09/26/2005 19:00:00 7.6 1.1 10.7 4.2 7.6 1.1 10.7 3.8 5.9 1.3 9.9 3 16 9 26 255 10.3 0 10.6 10.3 09/26/2005 19:10:00 7.1 1 10.3 3.8 7.1 1 9.9 4.2 5.5 1.3 10.3 3 16 10 0 255 10.2 0 10.3 10.1 09/26/2005 19:20:00 7.5 1.2 11.1 4.6 7.4 1.3 11.1 4.2 6.3 1.5 10.3 3 24 11 356 255 10.2 0 10.3 10.1 09/26/2005 19:30:00 7.5 1.3 11.1 4.6 7.5 1.3 11.1 4.2 6.3 1.3 10.7 3 29 11 38 255 10.5 0 10.6 10.3 09/26/2005 19:40:00 7.8 1.4 11.8 4.9 7.7 1.4 11.8 4.9 6.5 1.4 11.1 3.4 27 12 16 255 10.6 0 10.6 10.6 09/26/2005 19:50:00 7.8 1.2 11.5 4.2 7.8 1.3 11.5 3.8 6.8 1.4 10.3 3.4 25 10 21 255 10.6 0 10.6 10.6 09/26/2005 20:00:00 7.3 1.1 11.1 5.3 7.3 1.1 11.1 4.9 6 1.3 9.5 3 21 10 21 255 10.5 0 10.6 10.3 09/26/2005 20:10:00 5.9 1 8 3.8 5.8 1 8 3.4 4.9 1 8 2.6 26 11 20 255 10.3 0 10.6 10.3 09/26/2005 20:20:00 6.3 1 9.1 3.8 6.2 1 8.8 4.2 5.2 1.2 9.1 2.6 25 11 32 255 10.2 0 10.3 10.1 09/26/2005 20:30:00 6.4 1 9.5 3.4 6.3 1.1 10.3 3.8 5.2 1.1 8.4 2.3 30 12 73 255 10.2 0 10.3 10.1 09/26/2005 20:40:00 6.6 1.1 10.7 3.4 6.5 1.1 10.3 3.4 5.5 1.1 8.4 3.4 35 15 10 255 10.2 0 10.3 10.1 09/26/2005 20:50:00 4.6 0.9 7.6 3 4.6 0.9 7.6 2.6 3.5 0.9 6.8 1.5 54 16 46 255 10 0 10.3 9.8 09/26/2005 21:00:00 4.8 0.7 6.5 3 4.8 0.8 6.8 3 3.8 0.9 6.5 1.9 77 14 52 255 9.3 0.2 9.8 9 09/26/2005 21:10:00 4.6 0.8 7.2 2.6 4.6 0.8 7.2 3 3.6 0.7 5.7 1.9 79 12 73 255 8.8 0 9 8.5 09/26/2005 21:20:00 4.7 0.7 6.1 3 4.7 0.7 6.5 3 3.8 0.7 6.1 1.5 89 9 87 255 8.4 0 8.5 8.5 09/26/2005 21:30:00 5 1 6.8 2.3 5 0.9 7.2 2.3 3.9 0.9 6.1 1.5 84 12 88 255 8.4 0 8.5 8.5 09/26/2005 21:40:00 4.7 0.7 6.1 2.6 4.6 0.7 6.1 2.3 3.5 0.7 5.3 1.9 85 10 80 255 8.6 0 8.8 8.5 09/26/2005 21:50:00 4.1 0.7 6.1 1.9 4.1 0.8 6.1 1.5 3.2 0.8 4.9 1.1 86 14 85 255 8.4 0 8.8 8.5 09/26/2005 22:00:00 4.6 0.9 6.8 2.3 4.6 0.8 7.2 2.6 3.8 0.8 6.1 1.9 79 10 83 255 8.4 0 8.5 8.3 09/26/2005 22:10:00 4.8 0.8 6.8 1.5 4.7 0.8 6.8 2.3 3.9 0.8 5.7 0.7 87 12 90 255 8.1 0 8.5 8 09/26/2005 22:20:00 4.7 0.8 6.5 3 4.6 0.8 6.5 2.6 3.6 0.7 5.7 1.9 88 10 100 255 8 0 8.3 8 09/26/2005 22:30:00 5.1 0.7 6.8 3 5 0.7 6.8 3 3.9 0.8 6.1 1.1 78 9 70 255 8.3 0 8.5 8.3 09/26/2005 22:40:00 4.4 0.9 6.5 1.9 4.4 0.8 6.5 1.9 3.2 0.8 5.3 0.7 60 13 63 255 8.6 0 8.8 8.5 09/26/2005 22:50:00 5.4 0.9 8 3.4 5.4 0.9 8 3.4 4.4 1 8 1.9 45 11 42 255 9 0.1 9.3 8.8 09/26/2005 23:00:00 5.5 1 8.4 3 5.4 1 8.4 2.3 4.4 1 6.8 1.9 47 13 39 255 9.2 0 9.3 9 09/26/2005 23:10:00 5.1 0.9 7.6 2.6 5 1 7.6 2.3 4 0.9 6.5 2.3 58 13 46 255 9.2 0 9.3 9 09/26/2005 23:20:00 5.5 1.1 8.4 2.6 5.4 1.1 8.8 2.6 4.6 1.1 7.6 2.6 56 16 42 255 9.5 0.2 9.8 9.3 09/26/2005 23:30:00 5.1 0.9 8 2.6 5 0.9 7.6 3 4.1 1 7.2 1.9 58 13 66 255 10 0 10.1 9.8 09/26/2005 23:40:00 4.5 0.8 6.5 3 4.4 0.9 6.5 2.6 3.6 0.9 6.1 1.5 67 13 50 255 10 0 10.1 9.8 09/26/2005 23:50:00 4.7 1.1 8 1.9 4.6 1.1 8 1.5 3.9 1 6.5 1.5 65 13 61 255 10 0 10.1 9.8 09/27/2005 00:00:00 6 1.3 9.1 3.4 5.9 1.3 9.5 2.6 4.8 1.3 8.4 1.9 61 15 72 255 10.1 0 10.3 10.1 09/27/2005 00:10:00 6 1 8 2.3 5.9 1 8 3 4.5 1.1 7.2 1.9 53 15 55 255 10.2 0 10.6 10.1 09/27/2005 00:20:00 5.7 1 8.4 2.3 5.6 1 8.8 2.3 4.7 1 8 1.9 54 15 55 255 10.5 0 10.6 10.6 09/27/2005 00:30:00 5.1 0.9 7.6 2.6 5 1 8 2.3 4.4 0.9 7.2 2.3 67 13 83 255 10.5 0 10.6 10.6 09/27/2005 00:40:00 5.3 1 7.6 2.3 5.2 1 7.6 1.9 4.4 1.1 6.8 1.1 68 16 72 255 10.6 0 10.6 10.6 09/27/2005 00:50:00 5.1 0.9 8 2.6 4.9 0.9 8 2.3 4.1 1 7.2 1.9 68 15 58 255 10.6 0 10.9 10.6 09/27/2005 01:00:00 5.5 1.5 9.9 2.3 5.4 1.6 10.3 1.5 4.7 1.5 9.5 1.5 68 14 61 255 10.6 0 10.6 10.6 09/27/2005 01:10:00 6.5 1.4 9.9 3.4 6.4 1.4 9.9 3.4 5.4 1.3 9.5 2.3 76 15 70 255 10.7 0 11.1 10.6 09/27/2005 01:20:00 5.6 1.1 9.1 3 5.5 1.1 8.8 3 4.7 1.1 7.2 1.9 71 16 28 255 11.1 0 11.1 10.9 09/27/2005 01:30:00 6.6 1.5 11.1 3.8 6.5 1.5 10.7 3.4 5.8 1.5 11.1 3 49 16 69 255 11.1 0 11.1 11.1 09/27/2005 01:40:00 9 2 15.6 4.2 9 2.1 15.6 3.8 7.7 1.9 14.1 2.6 35 16 28 255 11.2 0 11.4 11.1 09/27/2005 01:50:00 8.6 1.7 15.3 4.9 8.5 1.7 15.6 4.6 7.2 1.7 11.8 3 32 14 27 255 11.3 0 11.4 11.1 09/27/2005 02:00:00 7.2 1.3 10.3 4.2 7 1.4 10.3 3.8 6.1 1.4 9.9 3.4 37 13 35 255 11.3 0 11.4 11.4 09/27/2005 02:10:00 6.2 1.2 9.5 3 6.1 1.2 9.5 2.6 5.1 1.1 8 2.6 54 17 22 255 11.4 0 11.4 11.4 09/27/2005 02:20:00 5.5 1.4 9.5 2.3 5.4 1.5 9.1 2.6 4.6 1.3 7.6 1.5 75 16 71 255 11.3 0 11.4 11.1 09/27/2005 02:30:00 5.8 1.7 10.3 1.9 5.8 1.7 10.7 2.6 4.7 1.7 9.1 1.5 81 19 99 255 11.1 0 11.4 11.1 09/27/2005 02:40:00 5.7 1.3 9.9 2.6 5.6 1.4 9.1 2.3 4.7 1.5 8.4 1.1 70 15 57 255 11.3 0 11.4 11.1 09/27/2005 02:50:00 6 1.3 9.5 1.9 5.9 1.3 9.1 1.9 5 1.4 8.8 1.5 82 17 86 255 11.1 0 11.4 11.1 09/27/2005 03:00:00 5.2 1.1 8 2.3 5.1 1.1 8 2.6 4.3 1.1 8 2.3 73 17 76 255 11.2 0 11.4 11.1 09/27/2005 03:10:00 5.7 1.2 9.1 3 5.6 1.3 9.1 2.3 4.6 1.2 7.2 1.5 70 17 42 255 11.2 0 11.4 11.1 09/27/2005 03:20:00 5.8 1.5 9.1 2.3 5.7 1.5 9.1 1.9 4.9 1.5 8.8 1.5 71 17 84 255 11.5 0 11.7 11.4 09/27/2005 03:30:00 5.5 1.3 9.9 1.9 5.5 1.4 9.9 1.9 4.6 1.5 9.1 1.5 71 17 69 255 11.6 0 11.7 11.4 09/27/2005 03:40:00 6.1 1.4 9.9 2.6 6 1.5 9.5 1.9 5.2 1.3 8.8 2.3 63 17 38 255 11.9 0 12.2 11.7 09/27/2005 03:50:00 6.7 1.5 11.1 3 6.6 1.6 11.1 2.6 5.6 1.5 10.3 1.9 68 17 57 255 12.3 0 12.5 12.2 09/27/2005 04:00:00 5.7 1.1 8.8 3.4 5.7 1.2 9.1 3 4.7 1.3 9.1 1.5 57 17 62 255 12.1 0.1 12.5 11.9 09/27/2005 04:10:00 5.4 1.2 8.4 2.6 5.3 1.2 8.8 2.3 4.6 1 8 2.3 59 13 46 255 11.7 0 11.9 11.7 09/27/2005 04:20:00 5.6 1.4 9.9 1.9 5.5 1.4 9.5 2.3 4.7 1.5 10.3 1.1 69 16 66 255 11.5 0 11.9 11.4 09/27/2005 04:30:00 5 1.2 8 1.9 4.8 1.2 8 1.5 4.2 1.2 8.4 0.7 72 13 63 255 11.9 0 11.9 11.7 09/27/2005 04:40:00 6 1.3 9.5 2.6 5.9 1.3 9.5 3.4 5 1.4 8.8 1.9 87 16 71 255 12 0 12.2 11.7 09/27/2005 04:50:00 5.2 1.2 8.8 2.6 5.1 1.3 8.4 2.3 4.2 1.3 8.8 1.1 87 19 97 255 11.7 0 11.9 11.7 09/27/2005 05:00:00 4.8 1.1 7.6 1.1 4.7 1.2 7.6 1.1 3.9 1.2 7.2 0.7 83 19 83 255 11.7 0 11.7 11.4 09/27/2005 05:10:00 6.3 1.1 9.1 3.4 6.2 1.1 9.1 3.4 5.3 1.1 8.8 1.9 86 15 93 255 11.7 0 11.7 11.4 09/27/2005 05:20:00 6.2 1.7 13 3.4 6.1 1.7 12.2 3 5 1.5 9.1 1.9 80 19 71 255 11.5 0 11.7 11.4 09/27/2005 05:30:00 5.6 1.7 13.7 2.3 5.5 1.8 13.7 2.3 4.6 1.6 11.1 1.9 78 21 66 255 11.5 0 11.7 11.4 09/27/2005 05:40:00 5.5 1.1 8.4 3 5.4 1.2 8.8 3 4.5 1.1 7.6 1.9 72 15 61 255 11.5 0 11.7 11.4 09/27/2005 05:50:00 4.7 1.4 9.1 1.5 4.6 1.4 9.1 1.9 4 1.3 9.9 0.7 78 19 77 255 11.7 0 11.9 11.7 09/27/2005 06:00:00 4 1.1 8 1.5 3.9 1.1 8.4 0.7 3.5 1 6.8 1.1 84 15 85 255 11.5 0 11.7 11.4 09/27/2005 06:10:00 5.8 1.5 10.3 2.3 5.7 1.5 9.9 2.3 4.8 1.4 8.8 1.5 73 19 84 255 11.6 0 11.7 11.7 09/27/2005 06:20:00 7 1.6 13.7 3.8 6.9 1.7 13.3 3.8 5.9 1.5 11.5 2.6 56 15 48 255 12 0 12.2 11.7 09/27/2005 06:30:00 6.8 1.5 10.7 3.4 6.8 1.5 11.1 3 5.7 1.7 11.5 1.5 75 15 39 255 12.1 0 12.2 11.9 09/27/2005 06:40:00 5.8 1.3 9.1 2.6 5.7 1.3 9.1 2.3 4.9 1.3 8 1.9 71 18 75 255 12.1 0 12.2 11.9 09/27/2005 06:50:00 7 1.8 12.2 3.4 7 1.9 12.2 3.4 6 1.6 11.1 2.6 67 18 60 255 12.1 0 12.5 11.9 09/27/2005 07:00:00 5.2 1.2 8 2.3 5.1 1.2 8 2.3 4.2 1.1 6.8 1.9 79 19 81 255 12.1 0 12.5 11.9 09/27/2005 07:10:00 5.8 1.7 9.9 2.3 5.7 1.7 9.9 2.3 4.9 1.7 9.9 1.1 78 20 46 255 11.9 0 11.9 11.9 09/27/2005 07:20:00 6.5 1.5 11.1 2.6 6.5 1.5 11.1 3 5.7 1.7 11.5 2.6 74 13 68 255 11.9 0 12.2 11.9 09/27/2005 07:30:00 6.5 1.6 10.7 2.6 6.4 1.6 11.1 2.3 5.5 1.6 10.3 1.9 77 16 87 255 12.1 0 12.2 11.9 09/27/2005 07:40:00 7.2 1.7 13.7 3.4 7.2 1.7 13 3.4 6.2 1.6 10.7 2.3 69 18 86 255 12.1 0 12.2 11.9 09/27/2005 07:50:00 6.9 1.2 11.1 4.6 6.8 1.3 11.1 4.2 5.7 1.3 9.1 3 68 17 66 255 12 0 12.2 11.9 09/27/2005 08:00:00 7.5 1.6 11.5 3.4 7.5 1.6 11.5 3.4 6.4 1.7 10.7 3 66 16 60 255 11.9 0 11.9 11.7 09/27/2005 08:10:00 5.8 1.6 11.1 3 5.8 1.6 11.5 3 4.8 1.5 10.7 1.9 64 19 59 255 11.7 0 11.9 11.7 09/27/2005 08:20:00 5.3 1.5 9.5 1.1 5.1 1.5 9.1 1.9 4.3 1.3 8.4 1.9 56 20 39 255 11.5 0 11.7 11.4 09/27/2005 08:30:00 6.1 1.3 10.3 2.6 6 1.3 9.9 2.6 4.9 1.5 9.5 2.3 71 22 88 255 11.5 0 11.7 11.4 09/27/2005 08:40:00 6.4 1.4 9.1 2.3 6.3 1.5 9.5 2.3 5.4 1.4 9.5 2.3 88 14 75 255 11.5 0 11.7 11.4 09/27/2005 08:50:00 6.5 1.6 10.3 3 6.5 1.6 11.1 2.3 5.5 1.5 9.5 1.9 72 17 69 255 11.7 0 11.7 11.7 09/27/2005 09:00:00 5.9 1.9 9.1 1.9 5.9 1.9 9.5 1.5 4.8 1.8 8.8 1.5 49 17 35 255 11.7 0 11.9 11.7 09/27/2005 09:10:00 5 0.9 7.2 2.3 4.9 0.9 7.2 2.3 4.2 0.9 6.5 2.3 76 22 51 255 11.6 0 11.7 11.4 09/27/2005 09:20:00 4.4 0.7 6.5 2.6 4.3 0.8 6.1 2.3 3.6 0.8 5.7 1.9 89 11 90 255 11.5 0 11.7 11.4 09/27/2005 09:30:00 4.8 1 7.6 2.6 4.7 1 7.2 2.3 3.9 1.1 6.8 1.5 94 14 100 255 11.5 0 11.7 11.4 09/27/2005 09:40:00 6 2 11.5 1.9 6 2 11.8 1.5 5.2 1.7 9.1 1.5 94 20 101 255 12.1 0.1 12.2 11.7 09/27/2005 09:50:00 5.5 1.6 9.1 1.9 5.5 1.6 9.1 2.3 4.7 1.7 9.1 1.5 104 22 114 255 12.1 0 12.2 11.9 09/27/2005 10:00:00 5.4 1.3 8 1.9 5.3 1.3 7.6 1.9 4.5 1.2 7.6 1.9 106 17 107 255 11.8 0 12.2 11.7 09/27/2005 10:10:00 4.8 0.9 7.6 2.6 4.5 1 7.2 2.6 4 0.9 7.2 1.5 94 17 81 255 11.8 0 11.9 11.7 09/27/2005 10:20:00 4.7 1 8.4 2.6 4.5 1 8 1.9 4 1 8 1.9 81 15 84 255 11.9 0 12.2 11.9 09/27/2005 10:30:00 5.7 1.4 9.9 2.6 5.6 1.4 9.9 2.6 4.6 1.5 9.5 1.5 82 18 62 255 12.3 0.1 12.5 12.2 09/27/2005 10:40:00 5.8 1.7 9.9 1.9 5.7 1.6 9.9 1.9 4.7 1.5 8.8 1.5 86 19 100 255 12.3 0 12.5 12.2 09/27/2005 10:50:00 5.4 1.6 9.9 1.1 5.3 1.7 9.5 0.4 4.5 1.4 9.5 1.9 97 19 94 255 11.9 0.1 12.2 11.7 09/27/2005 11:00:00 6.6 2 14.1 2.3 6.6 2 13.3 1.5 5.5 2 11.1 1.1 92 22 87 255 11.7 0 11.7 11.7 09/27/2005 11:10:00 6.4 1.8 11.8 2.6 6.3 1.7 11.5 2.3 5.6 1.7 11.8 1.9 86 21 84 255 11.7 0 11.7 11.7 09/27/2005 11:20:00 7.4 2.4 14.5 3 7.4 2.4 14.1 2.6 6.3 2.4 13 1.1 84 20 94 255 11.9 0 12.2 11.7 09/27/2005 11:30:00 8.7 2.3 14.5 3.4 8.6 2.3 14.1 3.4 7.2 2.1 12.6 2.3 88 20 90 255 12.2 0 12.2 11.9 09/27/2005 11:40:00 7.2 2.3 13.3 2.3 7.2 2.3 13.3 2.6 6.1 2.1 13 1.9 82 22 69 255 12.3 0 12.5 12.2 09/27/2005 11:50:00 9.1 2.5 17.6 3.8 9 2.5 17.9 3.4 7.9 2.5 16.8 2.6 80 20 81 255 12.5 0 12.7 12.5 09/27/2005 12:00:00 9.9 2.5 15.6 3.4 9.7 2.5 15.6 3.4 8.5 2.3 14.9 1.9 82 22 81 255 12.5 0 12.7 12.5 09/27/2005 12:10:00 8.5 2.5 16.1 3.4 8.4 2.4 16.1 3.8 7.1 2.3 14.5 1.9 84 21 79 255 12.5 0 12.7 12.5 09/27/2005 12:20:00 9.1 2.5 16.8 3 9.1 2.5 17.2 2.6 7.8 2.5 15.3 1.9 84 21 75 255 12.6 0 12.7 12.5 09/27/2005 12:30:00 8.9 2.9 17.2 3.4 8.8 2.9 17.2 3 7.8 2.8 16.8 2.6 84 20 70 255 12.7 0 12.7 12.7 09/27/2005 12:40:00 9.2 2.6 17.6 4.2 9.2 2.5 17.6 4.2 7.8 2.4 16.4 1.9 88 21 100 255 12.7 0 12.7 12.7 09/27/2005 12:50:00 9.5 2.8 17.2 2.6 9.5 2.8 17.2 3 8.4 2.8 14.9 1.5 85 18 60 255 12.7 0 12.7 12.7 09/27/2005 13:00:00 9.4 2.8 16.1 3.4 9.4 2.8 16.1 3.4 8.4 2.6 15.6 3 86 20 92 255 12.8 0 12.7 12.7 09/27/2005 13:10:00 9.3 3.3 19.1 2.6 9.2 3.3 19.1 3.4 7.9 2.9 14.9 1.5 88 22 115 255 12.8 0 12.7 12.7 09/27/2005 13:20:00 9.4 3.1 17.2 0.7 9.3 3.2 16.8 0.4 8.2 2.9 15.3 1.5 85 22 93 255 12.8 0 13 12.7 09/27/2005 13:30:00 7.2 2.5 13.7 1.9 7.1 2.4 13.3 1.9 6 2.5 13 0.4 84 22 89 255 12.8 0 12.7 12.7 09/27/2005 13:40:00 9.1 2.7 15.3 3 9 2.8 15.6 3 7.7 2.6 14.5 2.3 89 19 73 255 12.7 0 12.7 12.5 09/27/2005 13:50:00 10 2.3 17.2 4.6 9.9 2.3 17.6 5.3 8.6 2.2 13.3 3 78 18 42 255 12.5 0 12.7 12.5 09/27/2005 14:00:00 8.8 2.6 16.1 2.6 8.7 2.7 15.6 2.3 7.6 2.6 15.3 1.1 84 26 52 255 12.5 0 12.5 12.5 09/27/2005 14:10:00 9.6 2.5 16.8 4.2 9.6 2.6 17.2 3.8 8.1 2.4 15.3 3.4 87 21 80 255 12.5 0 12.7 12.5 09/27/2005 14:20:00 10 3.1 17.6 3 9.9 2.9 17.2 3 8.7 2.9 16.4 1.9 87 18 113 255 12.4 0 12.5 12.2 09/27/2005 14:30:00 9 2.5 17.2 2.6 9 2.5 16.8 2.6 7.8 2.3 14.9 3 85 22 94 255 12.3 0 12.5 12.2 09/27/2005 14:40:00 8.4 2.7 16.4 3 8.4 2.8 16.1 3.4 7.3 2.8 15.6 1.5 86 19 98 255 12.3 0 12.5 12.2 09/27/2005 14:50:00 9 2.4 16.4 4.2 9 2.4 15.6 4.6 7.5 2.3 14.1 2.6 86 18 95 255 12.2 0 12.2 11.9 09/27/2005 15:00:00 7.9 2.3 13 1.1 7.8 2.3 12.6 1.9 6.7 2.2 12.2 1.1 88 22 94 255 12 0 12.2 11.9 09/27/2005 15:10:00 7.4 2.3 14.5 2.3 7.3 2.3 14.1 3 6.3 2.3 13 1.9 85 19 89 255 11.8 0 11.9 11.7 09/27/2005 15:20:00 7.3 1.7 12.6 3 7.2 1.7 12.2 2.6 6.1 1.7 13.3 2.6 75 21 89 255 11.8 0 11.9 11.7 09/27/2005 15:30:00 8.6 1.9 14.5 4.2 8.5 2 14.9 4.9 7.5 1.8 13.7 3 75 20 84 255 11.9 0 11.9 11.7 09/27/2005 15:40:00 8.1 2.3 14.5 3.4 8 2.3 14.1 2.6 7 2.3 14.5 2.3 70 20 72 255 11.9 0 11.9 11.7 09/27/2005 15:50:00 8.7 2.2 14.9 4.2 8.6 2.3 15.3 4.2 7.2 2 14.9 2.3 65 18 63 255 11.7 0 11.9 11.7 09/27/2005 16:00:00 7.4 1.7 13 3 7.3 1.7 12.6 2.6 6.1 1.7 11.5 2.3 64 22 52 255 11.6 0 11.7 11.4 09/27/2005 16:10:00 6 1.7 10.7 1.9 5.8 1.7 10.3 1.9 5.1 1.7 10.3 1.5 67 18 71 255 11.3 0 11.4 11.1 09/27/2005 16:20:00 5.2 1.1 8.8 3 5.1 1.2 8.4 1.9 4.4 1.2 8 1.9 62 20 94 255 10.9 0.1 11.1 10.6 09/27/2005 16:30:00 5.2 1.3 8.8 0.7 5 1.3 8.8 0.4 4.2 1.3 6.8 0.4 63 22 71 255 10.7 0 10.9 10.6 09/27/2005 16:40:00 6.1 1.4 10.3 3.4 5.9 1.5 9.9 3.4 4.8 1.5 8.8 1.1 72 22 62 255 10.9 0 11.1 10.6 09/27/2005 16:50:00 6.3 1 8.8 3.4 6.1 1 8.8 2.6 5.2 1.1 7.6 2.6 73 16 106 255 10.7 0 10.9 10.6 09/27/2005 17:00:00 5.6 1.3 9.5 1.9 5.4 1.3 9.9 1.5 4.5 1.3 8.8 0.7 75 17 80 255 10.6 0 10.6 10.6 09/27/2005 17:10:00 3.8 0.9 6.1 1.9 3.5 0.9 5.7 1.5 3 0.8 5.3 1.5 92 20 66 255 10.4 0 10.6 10.3 09/27/2005 17:20:00 4.2 1.3 8 1.5 3.9 1.3 7.6 1.1 3.3 1.1 6.5 1.1 94 20 49 255 10.3 0 10.6 10.3 09/27/2005 17:30:00 4.9 1.3 8.8 1.5 4.7 1.4 9.1 1.5 4.1 1.4 8.4 1.5 93 15 106 255 10.5 0 10.6 10.6 09/27/2005 17:40:00 4.7 1 6.8 2.3 4.5 1 6.5 1.5 3.7 1 6.5 1.1 87 16 86 255 10.5 0 10.6 10.3 09/27/2005 17:50:00 5.4 1.3 9.1 3 5.3 1.4 9.1 2.3 4.4 1.2 8 1.5 85 15 95 255 10.5 0 10.9 10.6 09/27/2005 18:00:00 5.9 1.2 9.1 2.6 5.8 1.2 9.5 3 4.8 1.3 9.1 1.9 89 14 91 255 10.7 0 10.9 10.6 09/27/2005 18:10:00 6.3 1.4 9.5 3.4 6.2 1.4 9.5 3 5.1 1.5 8.4 1.1 95 14 94 255 10.9 0 11.1 10.9 09/27/2005 18:20:00 7.4 2 12.6 2.6 7.3 2 11.8 2.3 6.3 2.1 12.2 1.5 95 17 43 255 11 0 11.1 10.9 09/27/2005 18:30:00 8.2 1.8 12.6 3.4 8.2 1.8 12.6 4.2 7 1.8 12.2 2.6 96 16 80 255 10.9 0.1 11.1 10.9 09/27/2005 18:40:00 7.6 1.6 12.6 3.8 7.5 1.6 13 3.4 6.2 1.7 11.1 2.6 93 17 76 255 10.7 0 11.1 10.6 09/27/2005 18:50:00 8.4 2.2 13.3 4.2 8.3 2.2 13.3 2.6 7.2 2 12.6 1.5 87 20 61 255 11 0 11.1 10.9 09/27/2005 19:00:00 9.3 2.3 16.1 4.2 9.2 2.2 16.8 3.8 7.9 2 14.1 3 93 16 76 255 10.7 0 10.9 10.6 09/27/2005 19:10:00 8.2 2.5 14.9 3 8.2 2.4 14.5 3 6.9 2.6 13.7 1.5 92 18 94 255 10.5 0 10.6 10.3 09/27/2005 19:20:00 9 1.8 13.7 3 8.9 1.8 13.3 2.6 7.4 2 12.6 3 91 19 71 255 10.3 0 10.6 10.3 09/27/2005 19:30:00 8.7 2.3 14.9 4.2 8.7 2.4 14.5 4.2 7.5 2.4 13.7 3.4 94 16 96 255 10.3 0 10.6 10.3 09/27/2005 19:40:00 8.8 2.4 15.6 3.8 8.8 2.4 15.6 3.8 7.3 2.2 13.7 2.6 88 20 79 255 10.3 0 10.6 10.3 09/27/2005 19:50:00 8.3 2.5 15.3 3.4 8.2 2.4 14.1 3.4 7.3 2.4 14.1 1.1 89 17 74 255 10.5 0 10.6 10.3 09/27/2005 20:00:00 7.5 2.2 14.5 1.1 7.5 2.2 14.5 2.3 6.3 2.2 14.1 1.5 92 19 100 255 10.3 0 10.6 10.3 09/27/2005 20:10:00 7.9 2.4 13 1.9 7.8 2.3 13 2.3 6.5 2.4 11.8 0.7 95 19 102 255 10.3 0 10.6 10.3 09/27/2005 20:20:00 8.3 3.1 14.5 2.6 8.2 3.1 14.1 1.9 6.9 2.8 13.7 1.1 90 22 106 255 10.3 0 10.6 10.3 09/27/2005 20:30:00 7.8 1.7 12.6 3.4 7.7 1.7 13 3.4 6.7 1.8 11.8 2.6 96 17 88 255 10.6 0 10.6 10.6 09/27/2005 20:40:00 7.2 2.2 13.3 2.6 7 2.2 12.6 2.3 5.8 2.3 11.5 1.5 83 18 80 255 10.5 0 10.6 10.6 09/27/2005 20:50:00 7.3 2 13 2.6 7.3 1.9 12.6 2.3 6.2 1.7 11.5 1.9 82 17 84 255 10.5 0 10.6 10.6 09/27/2005 21:00:00 6.4 1.9 11.5 2.6 6.3 2 11.5 1.9 5.3 1.7 9.9 1.5 76 19 100 255 10.4 0 10.6 10.3 09/27/2005 21:10:00 7.2 2.4 13.3 1.9 7.1 2.5 13.7 1.5 6 2.3 13 1.5 77 17 76 255 10.4 0 10.6 10.3 09/27/2005 21:20:00 5.6 1.3 9.1 2.3 5.5 1.3 9.1 2.3 4.6 1.3 7.6 2.3 71 18 77 255 10.3 0 10.6 10.3 09/27/2005 21:30:00 4.3 1 7.6 1.9 4.1 1.1 7.2 1.5 3.5 1 6.5 0.7 66 17 84 255 10.2 0 10.3 9.8 09/27/2005 21:40:00 4.8 1 6.8 1.9 4.6 1 6.8 1.9 3.5 1 6.1 1.1 79 17 76 255 9.8 0 10.1 9.6 09/27/2005 21:50:00 5.4 1.1 8.4 3 5.3 1.1 8.4 2.6 4.4 1.2 8 1.5 71 17 86 255 9.6 0 9.8 9.6 09/27/2005 22:00:00 6.3 1.2 8.8 3 6.2 1.2 9.1 3 5.1 1.1 8 2.3 65 15 75 255 9.4 0 9.6 9 09/27/2005 22:10:00 5 1 7.6 3 4.9 1 7.6 2.3 3.9 1 6.5 1.5 72 16 66 255 9.1 0 9.3 9 09/27/2005 22:20:00 4.9 1 8 2.6 4.8 1 7.6 2.3 4 1.1 6.8 1.5 86 17 103 255 9.1 0 9.3 9 09/27/2005 22:30:00 4.9 1.1 8 1.9 4.7 1.1 7.6 1.9 4 1.1 6.5 1.5 74 15 121 255 9.2 0 9.3 9 09/27/2005 22:40:00 4.8 1.1 7.6 1.9 4.6 1.1 8 1.5 3.9 1.1 6.8 1.5 93 19 141 255 9.2 0 9.3 9 09/27/2005 22:50:00 4.1 1.1 6.5 1.1 3.8 1.2 6.5 0.4 3.1 1.2 5.7 0.4 89 17 86 255 9 0 9.6 9 09/27/2005 23:00:00 4.7 1 7.2 1.9 4.4 1.1 8 1.5 3.7 1.3 6.8 0.4 97 15 108 255 8.9 0 9 9 09/27/2005 23:10:00 4.1 1.1 6.8 1.1 3.9 1.1 6.5 0.4 3 1 4.9 0.4 75 22 90 255 9 0 9 9 09/27/2005 23:20:00 5.5 1.5 8.8 2.3 5.3 1.5 8.8 1.9 4.2 1.3 7.6 0.7 85 20 76 255 9.1 0 9.3 9 09/27/2005 23:30:00 5 1.1 7.6 2.3 4.8 1.1 7.6 2.3 4.1 1.2 7.6 0.7 95 15 100 255 9.2 0 9.3 9 09/27/2005 23:40:00 4.6 1.1 7.2 1.9 4.4 1.1 7.2 1.9 3.5 1.2 6.5 0.7 90 14 104 255 9 0 9 9 09/27/2005 23:50:00 4.3 0.9 6.5 1.9 4.1 0.9 6.5 1.5 3.3 1 6.1 0.7 95 15 86 255 8.9 0 9 8.8 09/28/2005 00:00:00 4.2 1 6.8 1.9 4 1 6.5 1.5 3.4 0.9 5.7 1.1 101 13 109 255 8.9 0 9 8.8 09/28/2005 00:10:00 4 0.8 6.1 1.9 3.8 0.8 6.1 1.5 3 0.8 4.9 1.1 104 16 110 255 8.8 0 9 8.8 09/28/2005 00:20:00 4.7 1 7.6 2.6 4.5 1 7.6 2.3 3.8 1.1 7.2 1.5 106 15 106 255 8.9 0 9 8.8 09/28/2005 00:30:00 4.4 1 7.2 1.5 4.2 1.1 7.2 1.1 3.5 1 6.5 0.7 110 17 100 255 8.7 0 8.8 8.8 09/28/2005 00:40:00 5.2 1.2 8 2.3 5 1.2 7.6 1.9 4.1 1.3 7.6 1.1 111 16 101 255 8.7 0 8.8 8.5 09/28/2005 00:50:00 4.6 1.2 8 1.5 4.5 1.3 8.4 0.4 3.6 1.1 6.8 1.1 104 23 144 255 8.7 0 8.8 8.5 09/28/2005 01:00:00 5.4 1.3 8.8 1.5 5.3 1.3 9.1 2.3 4.2 1.4 8 0.4 97 16 100 255 8.6 0 8.8 8.5 09/28/2005 01:10:00 7.1 1.5 11.1 3.8 6.9 1.5 10.3 3 6 1.7 9.9 1.9 102 16 112 255 8.6 0 8.8 8.5 09/28/2005 01:20:00 8.2 1.9 13.3 3 8 1.8 13.3 3 6.8 2.1 13.7 1.1 100 16 90 255 8.8 0 9 8.8 09/28/2005 01:30:00 7.1 1.8 13.3 3 7 1.8 13 2.6 5.7 1.7 11.1 1.5 97 17 80 255 8.9 0 9 8.8 09/28/2005 01:40:00 8 1.6 11.8 3.8 8 1.6 11.8 3.8 6.6 1.7 10.7 2.6 100 14 94 255 8.9 0 9 9 09/28/2005 01:50:00 7 1.5 11.5 3.4 6.9 1.5 11.1 3.8 5.7 1.7 10.3 1.9 90 17 72 255 8.9 0 9 8.8 09/28/2005 02:00:00 6.9 1.5 11.5 2.3 6.7 1.5 11.1 1.1 5.6 1.4 9.9 1.5 94 15 89 255 8.7 0 8.8 8.5 09/28/2005 02:10:00 5.7 1.2 8.8 3 5.6 1.3 9.1 2.6 4.7 1.3 8.4 1.9 103 16 100 255 8.5 0 8.8 8.5 09/28/2005 02:20:00 6.4 1.4 10.3 3.4 6.2 1.3 10.3 3.4 5.2 1.3 8.8 1.9 107 15 112 255 8.3 0 8.5 8.3 09/28/2005 02:30:00 6.9 1.2 9.5 3.8 6.8 1.1 9.1 4.2 5.7 1.1 9.1 3 108 13 111 255 8.4 0 8.5 8.3 09/28/2005 02:40:00 6.7 1.4 10.3 3.8 6.6 1.4 10.3 3.4 5.3 1.5 9.5 2.3 102 15 86 255 8.4 0 8.8 8.3 09/28/2005 02:50:00 6.3 1.6 10.7 2.3 6.3 1.5 10.3 2.3 5 1.6 8.8 0.4 95 18 95 255 8.1 0 8.3 8 09/28/2005 03:00:00 6.9 1.6 10.7 3 6.8 1.7 10.7 2.6 5.7 1.6 9.5 1.9 99 17 93 255 8 0 8.3 7.8 09/28/2005 03:10:00 7.4 1.6 11.1 2.3 7.3 1.6 11.5 2.3 6.4 1.7 10.7 2.3 96 15 106 255 8.1 0 8.3 7.8 09/28/2005 03:20:00 5.6 1.4 8.8 1.5 5.4 1.3 8.8 1.9 4.5 1.5 8.4 1.1 80 21 59 255 8.1 0 8.3 8 09/28/2005 03:30:00 5.1 1.4 8.8 2.3 5 1.4 8.4 2.3 4.3 1.2 8 0.7 74 22 101 255 8.3 0 8.5 8.3 09/28/2005 03:40:00 5.5 1.1 8.4 3 5.3 1.1 9.9 3 4.2 1.1 6.8 1.5 80 17 83 255 8.3 0 8.5 8.3 09/28/2005 03:50:00 5.7 1.7 10.3 2.3 5.5 1.7 10.3 1.9 4.9 1.6 9.1 1.5 84 19 88 255 8.3 0 8.5 8.3 09/28/2005 04:00:00 6.6 1.7 10.7 2.6 6.5 1.7 10.3 2.6 5.6 1.6 9.1 1.5 84 16 60 255 8.3 0 8.5 8.3 09/28/2005 04:10:00 6.6 1.3 10.3 3 6.4 1.3 9.9 3 5 1.5 8.8 1.5 88 15 83 255 8.4 0 8.5 8.3 09/28/2005 04:20:00 6.4 1.4 10.3 2.6 6.3 1.4 10.3 2.6 5.2 1.5 9.1 1.1 89 17 98 255 8.4 0 8.5 8.5 09/28/2005 04:30:00 6.9 1.2 9.9 3.8 6.7 1.1 9.9 3.4 5.9 1.4 9.1 2.3 99 14 84 255 8.4 0 8.5 8.5 09/28/2005 04:40:00 5.7 1.3 9.5 2.3 5.5 1.3 9.5 1.9 4.4 1.4 8 1.5 97 18 109 255 8.4 0 8.5 8.3 09/28/2005 04:50:00 5.8 1.7 9.9 1.5 5.6 1.7 10.3 1.5 4.6 1.7 8.8 0.7 94 19 127 255 8.4 0 8.5 8.5 09/28/2005 05:00:00 6.6 1.8 11.8 3 6.4 1.7 11.8 3 5.6 1.5 9.9 2.3 102 17 113 255 8.5 0 8.8 8.5 09/28/2005 05:10:00 7 1.5 11.5 3.4 6.9 1.5 11.1 3 5.6 1.5 9.9 1.5 102 16 110 255 8.6 0 8.8 8.5 09/28/2005 05:20:00 6.4 1.6 11.5 3.4 6.3 1.5 11.8 3.4 5.1 1.7 11.1 1.9 96 19 105 255 8.7 0 9 8.8 09/28/2005 05:30:00 6.4 1.7 11.1 3 6.3 1.6 10.7 2.3 5.6 1.7 10.3 1.5 99 15 97 255 8.7 0 8.8 8.8 09/28/2005 05:40:00 6.2 1.6 10.3 3 6.1 1.5 9.9 2.3 4.9 1.7 10.3 1.5 97 16 109 255 8.7 0 8.8 8.8 09/28/2005 05:50:00 6.1 1.5 10.3 2.3 5.8 1.5 10.7 2.6 5 1.7 9.5 1.5 91 16 85 255 8.7 0 8.8 8.8 09/28/2005 06:00:00 5.6 1.3 9.9 2.6 5.4 1.3 9.9 2.6 4.6 1.5 9.5 0.7 93 18 68 255 8.7 0 9 8.5 09/28/2005 06:10:00 5.8 1.4 9.9 2.6 5.7 1.3 9.9 2.6 4.7 1.3 8.8 1.9 100 18 93 255 8.5 0 8.8 8.5 09/28/2005 06:20:00 6.9 1.4 10.3 3.4 6.7 1.5 10.7 3 5.6 1.5 9.5 2.3 101 17 105 255 8.5 0 8.8 8.5 09/28/2005 06:30:00 5.6 1.3 9.1 2.3 5.5 1.3 8.8 2.3 4.5 1.3 8.4 1.5 89 21 74 255 8.6 0 8.8 8.5 09/28/2005 06:40:00 5.7 1.5 9.1 2.6 5.6 1.5 9.5 2.3 4.7 1.3 8.8 1.9 94 17 94 255 8.7 0 8.8 8.5 09/28/2005 06:50:00 5.5 1.3 8.8 2.6 5.4 1.3 8.4 2.3 4.3 1.3 7.2 1.1 84 19 87 255 8.6 0 8.8 8.5 09/28/2005 07:00:00 5.7 1.5 9.5 2.3 5.5 1.6 9.9 2.3 4.6 1.5 9.1 0.7 92 18 96 255 8.6 0 8.8 8.5 09/28/2005 07:10:00 5.9 1.4 9.1 2.3 5.8 1.3 8.8 1.9 4.9 1.5 8.8 0.7 95 16 83 255 8.7 0 9 8.5 09/28/2005 07:20:00 6 1.3 9.5 3 5.9 1.3 9.5 2.6 5 1.3 8.4 1.9 97 16 77 255 8.6 0.1 9 8.5 09/28/2005 07:30:00 5.2 1.2 8 2.6 5.1 1.2 8 2.3 4.1 1.1 6.8 1.1 100 17 108 255 8 0.2 8.5 7.5 09/28/2005 07:40:00 5.9 1.1 9.1 3 5.7 1.1 8.8 3.4 4.6 1.2 8.8 2.3 104 15 82 255 7.7 0 7.8 7.5 09/28/2005 07:50:00 5.6 1.4 8.8 1.9 5.5 1.4 9.1 1.5 4.3 1.3 7.2 0.7 97 17 94 255 7.9 0 8.3 7.8 09/28/2005 08:00:00 5 1.3 8.8 1.1 4.9 1.4 8.4 1.5 4 1.5 8 0.7 96 15 97 255 8.1 0 8.5 8 09/28/2005 08:10:00 5.1 1.2 8.4 1.9 5 1.1 7.2 2.3 4.1 1.1 7.2 1.5 94 14 84 255 8.4 0 8.5 8.3 09/28/2005 08:20:00 5 1 8.4 2.3 4.9 1 7.6 2.3 4.1 1 7.2 1.9 98 16 97 255 8.7 0 8.8 8.5 09/28/2005 08:30:00 4.7 1 6.8 2.6 4.5 1 6.8 1.9 3.7 1 6.1 1.9 103 17 91 255 8.7 0 9 8.8 09/28/2005 08:40:00 4.7 1 6.8 2.3 4.4 1 6.8 2.3 3.7 0.9 6.1 1.5 102 13 127 255 8.9 0 9 8.8 09/28/2005 08:50:00 4.5 1 7.2 1.9 4.3 1 7.2 1.9 3.6 1 6.5 1.5 104 15 105 255 9 0 9.3 9 09/28/2005 09:00:00 4.8 1 7.2 2.3 4.6 1.1 7.2 1.1 3.9 1 6.8 1.1 103 17 96 255 9.4 0 9.6 9.3 09/28/2005 09:10:00 5.7 1 8.4 3.4 5.5 1 8 3.4 4.7 1.1 8 1.9 98 13 92 255 9.6 0 9.8 9.6 09/28/2005 09:20:00 5.1 1.3 8.4 1.5 4.9 1.2 8.4 1.9 4.1 1.1 7.6 1.5 92 15 83 255 9.8 0 10.1 9.6 09/28/2005 09:30:00 4.8 1 7.6 2.3 4.6 1 7.2 2.3 4.1 1 8 1.9 96 14 88 255 10.1 0 10.3 9.8 09/28/2005 09:40:00 5.2 1.5 9.1 1.9 4.9 1.5 9.1 1.9 4.1 1.4 8 1.1 96 17 93 255 10.3 0 10.3 10.3 09/28/2005 09:50:00 5.4 1.8 11.5 1.5 5.2 1.8 10.3 0.7 4.4 1.7 8.8 0.4 100 18 108 255 10.3 0 10.6 10.3 09/28/2005 10:00:00 6.5 1.2 9.9 2.6 6.2 1.3 9.1 1.9 5.5 1.3 8.8 2.3 108 17 107 255 10.2 0 10.3 10.1 09/28/2005 10:10:00 5.3 1.5 9.5 1.9 5.1 1.6 9.1 1.5 4.4 1.5 8.4 1.1 98 19 103 255 10.2 0 10.3 10.1 09/28/2005 10:20:00 4.9 1.3 8 1.5 4.7 1.2 7.6 0.7 3.9 1.3 6.8 1.1 92 16 112 255 10.5 0 10.6 10.3 09/28/2005 10:30:00 5 1.2 8.8 2.3 4.8 1.2 8.4 1.5 4 1.3 7.6 0.7 92 17 111 255 10.7 0 10.9 10.6 09/28/2005 10:40:00 4.8 1.1 7.6 2.6 4.6 1.2 7.6 2.3 4.1 1.2 7.2 1.5 96 16 80 255 11.1 0 11.4 10.9 09/28/2005 10:50:00 6 1.1 8.4 3 5.7 1.1 8 3 5 1.2 8.4 2.3 102 14 106 255 11.6 0.2 11.9 11.4 09/28/2005 11:00:00 5.5 1.3 8.4 2.6 5.3 1.3 8 2.3 4.8 1.3 8 0.4 97 14 85 255 11.9 0 12.2 11.7 09/28/2005 11:10:00 5.2 1 8 2.6 5 1 8 2.3 4.6 1.1 8 1.9 94 14 104 255 12.5 0.1 12.7 12.2 09/28/2005 11:20:00 4.8 1 7.2 1.9 4.6 0.9 7.2 1.9 3.9 1.1 6.8 1.1 94 18 79 255 12.1 0 12.2 11.9 09/28/2005 11:30:00 5.2 1.1 8.8 3 5 1.1 8 2.3 4.3 1 7.2 1.5 105 14 91 255 11.9 0 12.2 11.7 09/28/2005 11:40:00 5.2 1.1 7.6 2.6 5 1.2 7.2 2.3 4.4 1.1 7.2 1.9 100 15 118 255 12.2 0 12.2 12.2 09/28/2005 11:50:00 5 1.2 8 2.3 4.7 1.2 8 2.3 4.2 1.3 7.2 1.1 101 18 73 255 12.1 0 12.2 11.9 09/28/2005 12:00:00 4.9 1.1 7.6 2.3 4.7 1.1 7.6 1.9 4.2 1 6.5 1.9 104 14 109 255 12.3 0.1 12.5 11.9 09/28/2005 12:10:00 5.4 1.1 8.8 2.6 5.2 1.1 8.4 1.9 4.5 1.2 8 2.3 101 17 88 255 12.7 0 12.7 12.5 09/28/2005 12:20:00 5.4 1.3 8.4 2.6 5.1 1.2 8.4 2.3 4.5 1.2 8 1.9 105 15 100 255 12.7 0 12.7 12.5 09/28/2005 12:30:00 4.6 1 7.6 2.3 4.4 1.1 7.2 1.1 3.7 1.1 6.8 1.1 91 16 86 255 12.7 0 12.7 12.7 09/28/2005 12:40:00 4.6 1 7.6 2.3 4.3 1 6.8 1.9 3.8 1 6.5 1.1 80 21 73 255 12.8 0 12.7 12.7 09/28/2005 12:50:00 4.1 0.9 6.8 1.5 3.9 1 6.8 1.9 3.4 1 5.7 0.7 79 22 104 255 12.8 0 12.7 12.7 09/28/2005 13:00:00 3.5 0.9 6.1 1.5 3.4 0.9 6.1 1.5 2.9 0.9 5.3 1.1 58 15 43 255 12.8 0 12.7 12.7 09/28/2005 13:10:00 2.8 0.7 4.6 1.1 2.7 0.8 4.6 0.4 2.2 0.9 4.2 0.4 49 20 41 255 12.7 0 12.7 12.5 09/28/2005 13:20:00 2.7 0.6 4.6 1.1 2.6 0.7 4.2 0.7 2.2 0.6 3.8 0.7 49 14 53 255 12.3 0.2 12.7 11.9 09/28/2005 13:30:00 2.8 0.8 4.6 0.7 2.4 1 4.6 0.4 2.1 0.9 3.8 0.4 78 15 79 255 11.5 0.2 11.9 11.1 09/28/2005 13:40:00 3.7 0.5 5.3 1.5 3.6 0.5 4.9 1.9 2.8 0.5 4.2 1.5 102 9 102 255 10.7 0.1 11.1 10.6 09/28/2005 13:50:00 3.4 0.8 4.9 1.1 3.1 0.8 4.9 0.7 2.4 0.7 4.2 0.7 94 13 97 255 10.5 0 10.6 10.6 09/28/2005 14:00:00 3.1 0.7 4.6 1.1 2.9 0.7 4.6 0.7 2.1 0.8 3.8 0.4 80 14 68 255 10.7 0.1 11.1 10.6 09/28/2005 14:10:00 2.4 0.7 4.6 0.7 2.3 0.8 4.2 0.4 1.7 0.8 4.2 0.4 68 17 43 255 11.1 0.1 11.4 10.9 09/28/2005 14:20:00 2.7 0.9 5.3 0.7 2.6 0.9 4.9 1.1 2 1 4.9 0.4 74 20 58 255 11.5 0 11.7 11.1 09/28/2005 14:30:00 2.9 0.9 4.9 0.4 2.7 0.9 4.9 0.4 2 0.8 4.6 0.4 82 19 55 255 11.7 0 11.7 11.7 09/28/2005 14:40:00 3.9 0.9 6.1 1.5 3.7 0.9 5.7 1.5 3.1 0.8 5.7 1.5 86 13 97 255 11.8 0 11.9 11.7 09/28/2005 14:50:00 4.1 0.8 6.1 1.9 3.9 0.9 6.1 1.1 3 0.8 5.3 1.1 96 14 92 255 12.1 0 12.2 11.9 09/28/2005 15:00:00 3.8 0.9 6.1 1.9 3.6 1 6.1 1.5 3 1.1 6.1 0.4 90 13 77 255 12.2 0 12.2 12.2 09/28/2005 15:10:00 3.5 0.7 5.7 1.5 3.3 0.7 4.9 1.9 2.6 0.7 4.9 1.1 90 17 98 255 12.3 0 12.5 12.2 09/28/2005 15:20:00 3.3 0.8 5.7 1.9 3.1 0.8 5.7 1.5 2.4 0.8 4.9 0.4 75 15 88 255 12.5 0 12.7 12.5 09/28/2005 15:30:00 3.9 1 7.2 1.5 3.7 1.1 6.8 0.7 3.2 0.8 6.5 1.1 63 19 70 255 12.7 0 12.7 12.5 09/28/2005 15:40:00 4.4 0.7 6.1 2.3 4.1 0.7 6.5 2.6 3.5 0.7 5.7 1.9 72 17 58 255 12.8 0 12.7 12.7 09/28/2005 15:50:00 3.7 0.8 6.1 1.9 3.5 0.8 6.1 1.5 2.9 0.9 5.7 0.7 67 17 47 255 12.7 0 12.7 12.7 09/28/2005 16:00:00 3.9 0.8 6.1 1.9 3.6 0.9 5.7 1.9 3.2 1 5.7 0.4 65 17 35 255 12.7 0 12.7 12.5 09/28/2005 16:10:00 3.6 0.9 6.5 1.9 3.4 1 6.5 0.7 3.1 1 6.1 1.1 64 19 38 255 12.7 0 12.7 12.5 09/28/2005 16:20:00 4.7 0.9 6.8 2.6 4.6 1 6.5 2.3 3.9 1 6.5 1.5 51 15 60 255 12.7 0 12.7 12.5 09/28/2005 16:30:00 4.2 1 6.5 1.9 4.1 1 6.1 1.5 3.6 0.9 6.1 1.5 55 15 40 255 12.4 0 12.7 12.2 09/28/2005 16:40:00 4.7 0.9 6.5 2.3 4.6 0.9 6.8 1.9 3.8 1 6.1 1.5 59 15 55 255 12.2 0 12.5 11.9 09/28/2005 16:50:00 4.1 0.9 6.5 1.5 3.9 1 6.5 1.1 3.2 1 5.3 0.7 53 15 55 255 11.9 0.1 12.2 11.7 09/28/2005 17:00:00 3.6 0.9 6.5 0.7 3.4 1 6.5 0.4 2.7 1 5.3 0.7 61 18 49 255 11.7 0 11.9 11.7 09/28/2005 17:10:00 3.7 1 6.8 1.5 3.6 1 6.8 0.7 3 1 5.7 0.7 57 14 82 255 11.7 0 11.7 11.7 09/28/2005 17:20:00 3.1 0.7 4.9 1.1 2.9 0.8 4.6 0.4 2.2 0.8 4.2 0.4 66 12 57 255 11.4 0 11.7 11.1 09/28/2005 17:30:00 3.1 0.7 5.3 1.1 3 0.8 5.7 1.1 2.4 0.7 4.2 0.4 54 13 60 255 11.1 0 11.1 11.1 09/28/2005 17:40:00 3.8 0.6 5.3 1.9 3.6 0.7 5.3 1.9 2.7 0.8 4.6 0.7 46 11 12 255 10.9 0 11.1 10.9 09/28/2005 17:50:00 4.1 0.7 5.7 2.3 4 0.7 5.7 1.9 3 0.8 5.3 1.1 51 10 45 255 10.9 0 11.1 10.9 09/28/2005 18:00:00 4.7 1.2 8.4 2.3 4.6 1.1 8.4 1.9 3.7 1.1 7.2 1.5 44 14 34 255 10.9 0 11.1 10.9 09/28/2005 18:10:00 5 1.2 8.4 2.3 4.9 1.2 8.4 2.3 4.1 1.2 7.2 1.5 50 15 51 255 11.1 0 11.1 11.1 09/28/2005 18:20:00 4.2 1 6.8 1.9 4.1 1 6.8 1.5 3.5 1.1 6.1 0.7 65 16 48 255 11.1 0 11.1 10.9 09/28/2005 18:30:00 4.5 0.8 7.2 1.9 4.3 0.9 6.8 1.1 3.8 1 6.1 0.7 63 15 67 255 10.8 0.1 11.1 10.6 09/28/2005 18:40:00 4.4 1 6.5 2.3 4.2 1 6.8 2.3 3.4 1 6.5 1.1 61 15 59 255 10.6 0 10.6 10.6 09/28/2005 18:50:00 5.1 1 8 2.6 4.9 1.1 7.6 2.3 4 1.1 6.8 1.5 63 15 58 255 10.5 0 10.6 10.6 09/28/2005 19:00:00 5 1 7.6 3 4.9 1 7.2 3 4 1 6.8 1.1 69 13 70 255 10.6 0 10.6 10.6 09/28/2005 19:10:00 5.1 1.1 8 2.6 5 1.2 7.6 2.3 4.2 1.1 6.5 1.1 65 14 58 255 10.5 0 10.6 10.6 09/28/2005 19:20:00 5.4 1 8 3 5.3 1.1 8 2.6 4.3 1.1 6.8 1.9 57 12 46 255 10.6 0 10.9 10.6 09/28/2005 19:30:00 4.2 0.7 6.1 2.6 4.1 0.8 6.5 2.6 3.1 0.8 4.9 0.7 64 16 37 255 10.6 0 10.9 10.6 09/28/2005 19:40:00 4 0.7 6.1 2.3 3.8 0.7 6.1 2.3 3.1 0.6 4.9 1.5 73 12 60 255 10.5 0 10.6 10.3 09/28/2005 19:50:00 4 0.7 5.7 2.3 3.9 0.8 5.7 2.3 3.1 0.9 5.3 1.1 75 12 53 255 10.5 0 10.6 10.3 09/28/2005 20:00:00 3.7 0.8 6.8 1.5 3.6 0.8 6.5 1.5 2.7 0.8 4.6 0.4 85 13 95 255 10.2 0 10.6 10.1 09/28/2005 20:10:00 3.9 0.9 6.8 1.1 3.8 0.9 6.8 1.1 2.9 0.9 5.7 0.7 84 13 84 255 10.1 0 10.3 10.1 09/28/2005 20:20:00 3.6 0.6 4.9 2.3 3.6 0.6 5.3 1.9 2.7 0.7 4.6 0.7 82 11 74 255 10.2 0 10.3 10.1 09/28/2005 20:30:00 3.6 0.8 6.1 1.9 3.6 0.7 5.7 1.5 2.8 0.7 4.9 1.5 85 13 68 255 10.1 0 10.3 10.1 09/28/2005 20:40:00 4 0.7 5.3 2.3 4 0.7 5.3 1.5 2.9 1 4.9 0.7 85 13 86 255 10 0 10.3 10.1 09/28/2005 20:50:00 4.1 0.7 6.1 2.6 4 0.7 5.7 2.3 3 0.7 4.9 1.1 81 12 71 255 10 0 10.1 9.8 09/28/2005 21:00:00 3.7 0.7 5.7 1.9 3.6 0.7 5.3 1.9 2.6 0.8 4.6 1.1 83 13 89 255 9.9 0 9.8 9.8 09/28/2005 21:10:00 3 0.8 5.3 0.7 2.8 0.8 4.9 0.7 2.1 0.7 3.8 0.4 74 16 76 255 9.8 0 9.8 9.8 09/28/2005 21:20:00 2.8 0.9 5.7 0.7 2.8 0.9 6.1 0.4 1.9 0.9 5.7 0.4 65 14 65 255 9.7 0 9.8 9.6 09/28/2005 21:30:00 3.6 0.6 5.7 2.3 3.5 0.6 5.3 1.9 2.5 0.7 4.6 0.7 79 11 100 255 9.8 0 9.8 9.6 09/28/2005 21:40:00 3.1 0.6 4.6 1.5 3 0.6 4.6 1.1 2.2 0.6 4.2 0.7 69 13 77 255 9.8 0 10.1 9.8 09/28/2005 21:50:00 3 0.7 4.9 1.1 3 0.7 4.6 1.1 2.2 0.9 4.2 0.4 62 12 68 255 9.8 0 10.1 9.6 09/28/2005 22:00:00 3.7 0.8 5.7 1.5 3.6 0.8 5.3 1.9 3 0.8 5.3 1.1 64 9 73 255 9.6 0 9.8 9.6 09/28/2005 22:10:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.9 2.1 0.5 3.8 0.7 63 8 50 255 9.3 0.1 9.6 9 09/28/2005 22:20:00 2.3 0.4 3 1.5 2.2 0.4 3.4 1.5 1.5 0.4 2.6 0.4 65 5 65 255 8.5 0.2 9 8.3 09/28/2005 22:30:00 1.6 0.5 2.6 0.4 1.4 0.4 2.3 0.4 0.7 0.3 1.5 0.4 72 12 60 255 7.9 0.2 8.3 7.5 09/28/2005 22:40:00 1.6 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.5 0.2 1.5 0.4 94 13 92 255 7.2 0 7.5 7 09/28/2005 22:50:00 2.3 0.6 4.2 0.4 2 0.6 3.8 0.4 1.2 0.6 3.4 0.4 112 11 111 255 7.1 0 7.3 7 09/28/2005 23:00:00 2.9 0.7 4.6 1.1 2.7 0.7 4.2 1.1 2.2 0.7 3.8 0.7 114 14 113 255 7.8 0.4 8.5 7.3 09/28/2005 23:10:00 3.1 0.9 4.9 0.4 2.9 0.9 4.9 0.4 2.2 0.9 4.9 0.4 114 15 121 255 8.7 0.1 9 8.5 09/28/2005 23:20:00 2.6 0.8 4.2 0.4 2.5 0.8 4.2 0.4 1.8 0.9 4.2 0.4 100 16 102 255 8.9 0 9 9 09/28/2005 23:30:00 2.1 0.8 4.2 0.4 1.9 0.8 3.8 0.4 1.4 0.7 3 0.4 99 15 97 255 8.8 0 9 8.8 09/28/2005 23:40:00 3 0.7 4.9 1.1 2.8 0.7 4.6 1.1 2 0.7 3.4 0.4 102 14 106 255 8.7 0 8.8 8.5 09/28/2005 23:50:00 2.6 0.7 4.6 0.4 2.4 0.8 4.2 0.7 1.7 0.7 3.4 0.4 103 17 104 255 8.7 0 8.8 8.5 09/29/2005 00:00:00 3.3 0.8 4.9 1.1 3.1 0.9 4.9 0.4 2.5 0.9 5.3 0.4 109 13 124 255 8.5 0 8.8 8.5 09/29/2005 00:10:00 3.7 0.8 5.7 1.5 3.5 0.8 5.3 1.5 2.6 0.9 4.9 0.4 105 14 105 255 8.4 0 8.5 8.5 09/29/2005 00:20:00 3.9 1 6.1 1.5 3.7 1 5.7 1.1 2.9 0.9 5.7 1.5 107 15 104 255 8.3 0 8.5 8.3 09/29/2005 00:30:00 4.1 0.9 6.1 1.5 3.9 0.9 6.1 1.5 2.9 0.9 5.3 0.7 110 14 102 255 8.1 0 8.3 8 09/29/2005 00:40:00 4.1 1 6.1 1.9 3.8 1 6.1 1.5 2.9 0.9 4.9 0.7 111 16 116 255 8 0 8.3 7.8 09/29/2005 00:50:00 3.8 0.9 6.1 1.5 3.6 1 5.3 1.1 2.6 0.9 4.9 0.4 112 15 116 255 7.8 0 8 7.8 09/29/2005 01:00:00 3.9 0.9 6.5 1.1 3.7 0.9 6.1 1.1 2.7 1 5.3 0.4 109 15 82 255 7.6 0 7.8 7.5 09/29/2005 01:10:00 3.9 0.8 5.7 1.5 3.8 0.8 5.7 1.5 2.8 0.8 5.3 0.7 103 15 99 255 7.5 0 7.8 7.3 09/29/2005 01:20:00 3.4 0.7 4.6 1.9 3.2 0.7 4.6 1.1 2.3 0.7 3.8 0.4 100 12 90 255 7.3 0 7.5 7.3 09/29/2005 01:30:00 1.9 0.8 4.2 0.4 1.6 0.8 3.8 0.4 0.9 0.7 3.8 0.4 80 15 87 255 6.7 0.2 7.3 6.2 09/29/2005 01:40:00 2.3 0.9 4.6 0.4 2.1 1 4.6 0.4 1.6 0.9 4.2 0.4 90 12 101 255 6.2 0 6.2 6 09/29/2005 01:50:00 4.1 0.6 6.1 2.6 4 0.6 5.7 2.6 3.1 0.6 4.9 1.9 99 9 100 255 6 0 6.2 5.7 09/29/2005 02:00:00 4.5 0.8 6.5 2.3 4.4 0.7 6.5 1.9 3.6 0.8 5.7 1.5 98 9 87 255 6.2 0 6.2 6 09/29/2005 02:10:00 4.3 0.7 6.1 2.3 4.2 0.7 6.1 2.3 3.3 0.8 5.3 1.1 98 11 86 255 6.2 0 6.5 6.2 09/29/2005 02:20:00 3.8 0.8 5.7 1.9 3.7 0.8 5.7 1.5 2.7 0.9 4.9 0.7 101 11 93 255 6.2 0 6.5 6.2 09/29/2005 02:30:00 4 0.7 5.3 2.3 3.9 0.6 5.3 2.3 2.7 0.7 4.6 1.1 106 12 113 255 6.1 0 6.2 5.7 09/29/2005 02:40:00 3.9 0.8 6.1 1.9 3.7 0.8 5.7 1.5 2.5 0.8 4.2 0.7 107 13 113 255 5.8 0 6 5.7 09/29/2005 02:50:00 3.8 0.8 5.7 1.9 3.7 0.8 5.7 1.5 2.6 1 4.9 0.7 103 12 102 255 5.9 0 6 5.7 09/29/2005 03:00:00 3.2 0.8 4.9 1.5 3 0.8 4.9 1.1 2.2 0.9 4.2 0.4 108 12 108 255 5.8 0 6 5.7 09/29/2005 03:10:00 2.8 0.7 4.6 1.1 2.6 0.8 4.2 0.7 1.8 0.8 3.8 0.4 110 13 102 255 5.7 0 6 5.7 09/29/2005 03:20:00 2.7 0.6 3.8 1.1 2.5 0.6 3.8 0.7 1.5 0.6 3 0.4 108 13 112 255 5.6 0 5.7 5.5 09/29/2005 03:30:00 2.8 0.6 3.8 0.7 2.6 0.5 3.8 0.7 1.7 0.6 3.4 0.4 107 11 93 255 5.4 0 5.7 5.5 09/29/2005 03:40:00 3 0.5 4.6 1.9 2.8 0.6 4.6 1.5 1.8 0.7 3.4 0.4 108 12 105 255 5.3 0 5.7 5.2 09/29/2005 03:50:00 3.1 0.6 4.6 1.5 2.9 0.7 4.2 1.1 2.1 0.7 3.4 0.4 108 11 99 255 5.6 0.1 5.7 5.5 09/29/2005 04:00:00 3.3 0.7 4.9 1.5 3.2 0.7 4.9 1.5 2.3 0.8 3.8 0.4 110 10 108 255 5.8 0 6 5.7 09/29/2005 04:10:00 2.9 0.9 4.6 0.7 2.8 0.9 4.6 0.4 1.9 0.8 4.2 0.4 110 16 123 255 6.1 0 6.2 6 09/29/2005 04:20:00 3.2 0.8 4.9 0.7 3 0.8 4.6 0.4 2.2 0.8 4.2 0.4 111 17 98 255 6.2 0 6.2 6.2 09/29/2005 04:30:00 2.6 0.7 4.6 1.1 2.4 0.8 4.2 0.4 1.5 0.7 3 0.4 107 16 110 255 6.2 0 6.2 6.2 09/29/2005 04:40:00 3.1 0.8 4.9 1.1 2.7 1 4.9 0.4 1.9 0.8 4.2 0.4 109 16 102 255 6.2 0 6.2 6.2 09/29/2005 04:50:00 3.2 0.7 5.3 1.5 3 0.7 4.6 1.1 2.2 0.8 4.6 0.4 109 15 106 255 6.2 0 6.2 6.2 09/29/2005 05:00:00 2.9 0.7 4.6 1.5 2.7 0.7 4.2 1.1 1.9 0.7 3.4 0.4 108 13 94 255 6.2 0 6.2 6.2 09/29/2005 05:10:00 2.6 0.7 4.6 1.1 2.5 0.7 4.2 0.4 1.7 0.8 3.8 0.4 92 14 95 255 6.2 0 6.5 6.2 09/29/2005 05:20:00 2.2 0.5 4.2 0.7 2 0.6 3.8 0.4 1.1 0.6 2.6 0.4 94 13 80 255 6.2 0 6.2 6.2 09/29/2005 05:30:00 2.2 0.6 3.8 0.4 2.2 0.6 3.8 0.4 1.4 0.6 2.6 0.4 102 12 90 255 6.2 0 6.2 6 09/29/2005 05:40:00 2.6 0.8 4.2 0.7 2.6 0.7 4.2 0.7 1.6 0.9 3.4 0.4 109 11 99 255 6.1 0 6.2 6 09/29/2005 05:50:00 2.6 0.7 4.2 0.4 2.6 0.6 4.2 0.7 2 0.6 3.4 0.4 106 10 91 255 6.2 0 6.5 6.2 09/29/2005 06:00:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.7 0.6 3 0.4 101 10 99 255 6.4 0 6.5 6.2 09/29/2005 06:10:00 2.2 0.5 3.8 0.7 2.3 0.5 3.4 0.7 1.5 0.6 2.6 0.4 96 10 91 255 6.4 0 6.5 6.2 09/29/2005 06:20:00 1.9 0.5 3 0.7 2.1 0.4 3.4 1.1 1.4 0.5 2.6 0.4 91 8 90 255 6.2 0 6.2 6.2 09/29/2005 06:30:00 2.1 0.7 3.8 0.4 2.3 0.6 3.4 0.7 1.5 0.5 2.6 0.4 104 11 115 255 6.2 0 6.2 6 09/29/2005 06:40:00 2 0.6 3.8 0.7 2.2 0.5 3.8 1.1 1.2 0.6 3 0.4 115 12 109 255 6.1 0 6.2 6 09/29/2005 06:50:00 2.7 0.7 4.2 0.7 2.8 0.6 4.2 1.1 1.9 0.7 3.8 0.4 111 11 80 255 6.2 0 6.5 6.2 09/29/2005 07:00:00 2.6 0.7 4.6 0.7 2.6 0.6 4.2 0.7 1.8 0.6 3.4 0.4 105 11 108 255 6.5 0 6.7 6.2 09/29/2005 07:10:00 2.6 0.5 3.8 1.1 2.4 0.5 3.4 0.7 1.7 0.5 3 0.4 103 10 101 255 6.6 0 6.7 6.5 09/29/2005 07:20:00 2.8 0.5 4.2 1.1 2.5 0.5 3.8 0.4 1.9 0.6 3.4 0.4 107 9 96 255 6.7 0 6.7 6.7 09/29/2005 07:30:00 3.2 0.5 4.6 1.9 2.9 0.5 3.8 1.5 2.1 0.5 3.4 0.7 98 10 104 255 6.7 0 7 6.7 09/29/2005 07:40:00 3.3 0.5 4.2 1.9 3.1 0.5 3.8 1.1 2.4 0.6 3.8 0.7 104 9 86 255 6.9 0 7 6.7 09/29/2005 07:50:00 3.1 0.5 3.8 1.5 2.8 0.5 3.8 1.1 2 0.7 3.8 0.4 107 11 122 255 7 0 7.3 7 09/29/2005 08:00:00 2.2 0.6 3.8 0.4 1.9 0.6 3.8 0.4 1.2 0.7 2.6 0.4 114 15 118 255 7.1 0 7.3 7.3 09/29/2005 08:10:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.4 0.5 3 0.4 113 13 97 255 7.3 0 7.3 7.3 09/29/2005 08:20:00 2.4 0.7 3.8 0.4 2.1 0.8 3.8 0.4 1.6 0.6 3 0.4 118 15 118 255 7.4 0 7.5 7.3 09/29/2005 08:30:00 2.2 0.5 3.8 0.7 2 0.6 3.4 0.4 1.5 0.6 2.6 0.4 115 13 100 255 7.5 0 7.5 7.5 09/29/2005 08:40:00 1.9 0.6 3.4 0.4 1.5 0.7 3 0.4 1.1 0.6 2.6 0.4 112 14 93 255 7.6 0 7.8 7.5 09/29/2005 08:50:00 1.7 0.5 3 0.4 1.4 0.6 2.6 0.4 1 0.5 2.6 0.4 114 15 100 255 7.8 0 7.8 7.8 09/29/2005 09:00:00 2 0.7 3.4 0.4 1.6 0.8 3.4 0.4 1.2 0.6 2.6 0.4 119 17 112 255 8 0 8.3 7.8 09/29/2005 09:10:00 1.8 0.6 3.4 0.4 1.5 0.6 3 0.4 1 0.5 2.6 0.4 105 17 103 255 8.2 0 8.5 8 09/29/2005 09:20:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 96 13 102 255 8.4 0 8.5 8.5 09/29/2005 09:30:00 1.2 0.5 2.3 0.4 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 95 12 97 255 8.7 0 9 8.5 09/29/2005 09:40:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.4 1.9 0.4 98 15 104 255 8.9 0 9 8.8 09/29/2005 09:50:00 1.9 0.5 3 0.4 1.7 0.5 2.6 0.4 1.4 0.5 2.3 0.4 100 8 104 255 9.1 0 9.3 9 09/29/2005 10:00:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 106 12 102 255 9.4 0 9.6 9.3 09/29/2005 10:10:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 104 15 146 255 9.8 0 10.1 9.6 09/29/2005 10:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 90 15 75 255 10.2 0 10.3 9.8 09/29/2005 10:30:00 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 46 26 60 255 10.3 0 10.6 10.3 09/29/2005 10:40:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 3 15 346 255 10.7 0 10.9 10.6 09/29/2005 10:50:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 352 5 348 255 11.1 0 11.1 10.9 09/29/2005 11:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 353 0 353 255 11.1 0 11.4 11.1 09/29/2005 11:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 4 15 353 255 11.3 0 11.7 11.1 09/29/2005 11:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 35 10 25 255 11.6 0 11.7 11.4 09/29/2005 11:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 355 20 4 255 11.9 0.1 12.2 11.7 09/29/2005 11:40:00 0.5 0.2 1.9 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 355 17 336 255 12.4 0 12.7 12.2 09/29/2005 11:50:00 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.8 0.3 1.5 0.4 351 17 339 255 12.9 0.1 13.3 12.5 09/29/2005 12:00:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 6 15 3 255 13.1 0 13.3 12.7 09/29/2005 12:10:00 1.1 0.7 3 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 287 43 343 255 14.2 0.3 14.6 13.3 09/29/2005 12:20:00 1.2 0.8 3.4 0.4 1.3 0.8 3.4 0.4 1.2 0.7 3.4 0.4 266 35 271 255 14.1 0.2 14.6 13.8 09/29/2005 12:30:00 1.9 0.7 3.8 0.4 1.8 0.7 3 0.4 1.6 0.6 3.4 0.4 290 29 280 255 13.8 0 14.6 13.5 09/29/2005 12:40:00 2.1 0.8 3.8 0.4 2.1 0.8 3.8 0.4 1.8 0.8 3.8 0.4 294 30 325 255 13.7 0 14.1 13.5 09/29/2005 12:50:00 2 0.8 4.2 0.4 2 0.7 3.8 0.4 1.5 0.6 3 0.4 270 38 294 255 13.7 0 14.1 13.5 09/29/2005 13:00:00 1.7 1.1 4.2 0.4 1.6 1.1 4.2 0.4 1.6 1 4.2 0.4 273 29 289 255 13.5 0.1 13.8 13 09/29/2005 13:10:00 1.9 1.1 4.9 0.4 1.9 1 4.9 0.4 1.5 1 4.9 0.4 259 32 272 255 12.9 0.1 13.5 12.7 09/29/2005 13:20:00 1.7 0.9 4.2 0.4 1.6 0.9 3.4 0.4 1.5 0.8 3.4 0.4 284 35 296 255 13.3 0 13.8 13 09/29/2005 13:30:00 2.2 1 4.6 0.4 2.3 1 4.6 0.4 1.9 0.9 3.8 0.4 264 21 256 255 13.3 0 13.5 13 09/29/2005 13:40:00 1.9 1 4.9 0.4 1.7 1 4.6 0.4 1.4 1 4.6 0.4 279 22 311 255 13.1 0 13.8 13 09/29/2005 13:50:00 3 1 5.7 1.1 3 0.9 4.9 0.4 2.5 0.9 4.9 0.4 300 17 317 255 14.1 0.3 15.2 13.5 09/29/2005 14:00:00 2.7 1 4.9 0.4 2.6 1 4.6 0.4 2.2 1 4.6 0.4 295 27 275 255 15.4 0.2 16 14.9 09/29/2005 14:10:00 2.6 1.2 4.9 0.4 2.5 1.2 4.9 0.4 2.3 1.1 4.9 0.4 288 32 309 255 15.6 0.3 16.3 15.2 09/29/2005 14:20:00 2.2 0.9 4.6 0.4 2.2 0.7 4.2 0.4 1.9 0.7 3.8 0.4 265 24 264 255 15.2 0.4 16.3 14.6 09/29/2005 14:30:00 2.4 0.9 4.2 0.4 2.4 0.8 4.2 0.7 2.1 0.8 4.2 0.4 293 21 290 255 14.4 0.1 15.2 14.4 09/29/2005 14:40:00 1.5 0.9 3 0.4 1.5 0.8 3.4 0.4 1.1 0.7 3 0.4 280 41 287 255 15 0 15.5 14.6 09/29/2005 14:50:00 1.5 1 4.2 0.4 1.5 1 4.2 0.4 1.3 0.8 4.2 0.4 282 41 294 255 15 0 15.7 14.9 09/29/2005 15:00:00 1.9 0.7 3.4 0.4 2 0.7 3.4 0.4 1.7 0.7 3.4 0.4 240 26 220 255 14.9 0 15.5 14.6 09/29/2005 15:10:00 1.8 1 3.8 0.4 1.9 0.9 3.8 0.4 1.5 0.8 4.2 0.4 261 41 295 255 14.9 0 15.5 14.6 09/29/2005 15:20:00 3.3 0.8 4.9 1.1 3.2 0.8 4.9 1.5 2.6 1 4.9 0.4 293 19 283 255 14.7 0 15.5 14.4 09/29/2005 15:30:00 4 1 6.1 1.1 4.1 0.9 6.1 1.1 3 1.1 5.7 0.4 275 15 274 255 13.9 0.1 14.6 13.5 09/29/2005 15:40:00 2.2 1.2 4.9 0.4 2.3 1.1 4.9 0.4 2 1 4.6 0.4 280 22 281 255 13.7 0 14.4 13.5 09/29/2005 15:50:00 2.7 1.1 5.3 0.4 2.7 1 4.9 0.4 1.9 1 4.6 0.4 266 29 280 255 13.7 0 13.8 13.5 09/29/2005 16:00:00 2.2 1.1 4.9 0.4 2.2 1.1 4.6 0.4 1.7 0.9 4.6 0.4 263 23 249 255 13.7 0 13.8 13.5 09/29/2005 16:10:00 2.9 0.8 4.6 1.1 2.9 0.8 4.9 1.1 2.2 0.8 4.9 0.4 254 13 261 255 13.4 0 13.8 13.3 09/29/2005 16:20:00 1.7 0.9 3.8 0.4 1.8 0.8 3.8 0.4 1.3 0.8 3.4 0.4 259 22 242 255 13.4 0 13.8 13.3 09/29/2005 16:30:00 1.9 1.2 4.2 0.4 1.9 1.1 4.2 0.4 1.5 1 3.8 0.4 292 18 290 255 13.4 0 13.8 13.3 09/29/2005 16:40:00 2.5 1.1 5.3 0.4 2.4 1.1 4.9 0.4 1.9 1 3.8 0.4 272 21 252 255 13.2 0 13.8 13 09/29/2005 16:50:00 1.7 1 4.2 0.4 1.7 1 4.2 0.4 1.2 0.9 4.2 0.4 265 30 271 255 12.9 0 13.3 12.7 09/29/2005 17:00:00 1.5 0.7 3 0.4 1.4 0.7 3 0.4 0.9 0.6 3 0.4 275 15 269 255 12.7 0 12.7 12.5 09/29/2005 17:10:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.6 0.4 1.9 0.4 262 15 260 255 12.5 0 12.7 12.2 09/29/2005 17:20:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 275 5 281 255 12.3 0 12.5 12.2 09/29/2005 17:30:00 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 290 13 293 255 11.9 0.1 12.2 11.7 09/29/2005 17:40:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 1 0.6 2.6 0.4 303 12 312 255 11.7 0 11.7 11.4 09/29/2005 17:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 294 14 299 255 11.3 0 11.7 11.1 09/29/2005 18:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 286 0 286 255 10.7 0.1 11.1 10.6 09/29/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 10.2 0 10.6 9.8 09/29/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 9.8 0.1 10.1 9.6 09/29/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 9.4 0 9.6 9.3 09/29/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 9 0 9.3 9 09/29/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 8.6 0.1 9 8.5 09/29/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 255 255 8.3 0 8.5 8.3 09/29/2005 19:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 16 79 86 255 8.1 0 8.5 8 09/29/2005 19:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 86 255 8 0 8.3 7.8 09/29/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 255 255 7.8 0 8 7.8 09/29/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 255 255 7.8 0 8 7.8 09/29/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 0 255 255 7.9 0 8 7.8 09/29/2005 20:00:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 25 24 86 255 8 0 8 7.8 09/29/2005 20:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 15 0 15 255 8 0 8.3 8 09/29/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 8.1 0 8.3 8 09/29/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 8.2 0 8.3 8.3 09/29/2005 20:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 15 255 8.1 0 8.3 8 09/29/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 8.1 0 8.3 8 09/29/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 8 0 8.3 8 09/29/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 8.1 0 8.3 8 09/29/2005 21:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 15 255 8 0 8.3 7.8 09/29/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 255 255 7.8 0 8 7.8 09/29/2005 21:40:00 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 332 20 15 255 7.8 0 7.8 7.8 09/29/2005 21:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 268 6 266 255 7.8 0 7.8 7.8 09/29/2005 22:00:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 253 6 252 255 7.8 0 7.8 7.8 09/29/2005 22:10:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0 0.7 0.4 245 3 250 255 7.8 0 7.8 7.8 09/29/2005 22:20:00 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 243 0 243 255 7.8 0 8 7.8 09/29/2005 22:30:00 1.3 0.2 1.9 0.7 1.1 0.2 1.9 0.4 0.4 0.2 1.1 0.4 217 7 215 255 8 0 8 7.8 09/29/2005 22:40:00 1.1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 214 0 214 255 8 0 8.3 8 09/29/2005 22:50:00 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 207 6 216 255 8.1 0 8.3 8 09/29/2005 23:00:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 167 20 147 255 8.1 0 8.3 8.3 09/29/2005 23:10:00 1.8 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.1 0.5 2.3 0.4 127 8 132 255 8.3 0.1 8.5 8.3 09/29/2005 23:20:00 1.7 0.3 2.6 1.1 1.5 0.3 2.3 0.7 0.9 0.3 1.9 0.4 144 8 153 255 8.4 0 8.5 8.5 09/29/2005 23:30:00 1 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 177 10 157 255 8.3 0 8.5 8.3 09/29/2005 23:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 229 30 181 255 8.3 0 8.5 8.3 09/29/2005 23:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 224 36 171 255 8.3 0 8.5 8.3 09/30/2005 00:00:00 0.9 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 202 23 174 255 8.3 0 8.5 8.3 09/30/2005 00:10:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 206 17 210 255 8.3 0 8.5 8.3 09/30/2005 00:20:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 201 11 204 255 8.4 0 8.5 8.3 09/30/2005 00:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 189 12 223 255 8.4 0 8.5 8.5 09/30/2005 00:40:00 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 118 27 108 255 8.4 0 8.5 8.5 09/30/2005 00:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 122 36 101 255 8.5 0 8.5 8.5 09/30/2005 01:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 180 0 181 255 8.5 0 8.5 8.5 09/30/2005 01:10:00 0.9 0.4 1.9 0.4 0.7 0.3 1.9 0.4 0.6 0.3 1.5 0.4 163 16 144 255 8.5 0 8.5 8.5 09/30/2005 01:20:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 154 3 153 255 8.4 0 8.5 8.5 09/30/2005 01:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 159 0 159 255 8.4 0 8.5 8.5 09/30/2005 01:40:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 154 8 143 255 8.4 0 8.5 8.3 09/30/2005 01:50:00 1.6 0.4 2.6 0.4 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 141 7 144 255 8.4 0 8.5 8.3 09/30/2005 02:00:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 148 4 151 255 8.5 0 8.5 8.5 09/30/2005 02:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 142 13 149 255 8.5 0 8.5 8.5 09/30/2005 02:20:00 1.1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 133 8 127 255 8.4 0 8.5 8.5 09/30/2005 02:30:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 146 5 148 255 8.4 0 8.5 8.3 09/30/2005 02:40:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 147 5 140 255 8.4 0 8.5 8.3 09/30/2005 02:50:00 1.4 0.3 2.3 0.4 1.2 0.3 1.9 0.4 0.9 0.4 1.9 0.4 156 9 160 255 8.4 0 8.5 8.5 09/30/2005 03:00:00 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 170 5 173 255 8.4 0 8.5 8.3 09/30/2005 03:10:00 1.4 0.4 2.3 0.4 1.3 0.4 1.9 0.4 0.9 0.4 1.9 0.4 171 8 171 255 8.4 0 8.5 8.3 09/30/2005 03:20:00 1.8 0.6 3 0.4 1.6 0.6 3 0.4 1.2 0.7 3 0.4 158 12 153 255 8.3 0 8.5 8.3 09/30/2005 03:30:00 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.3 0.4 146 12 134 255 8.3 0 8.5 8.3 09/30/2005 03:40:00 1.4 0.4 2.3 0.4 1.3 0.4 2.6 0.4 0.9 0.4 1.9 0.4 160 15 110 255 8.3 0 8.3 8.3 09/30/2005 03:50:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1 0.5 2.3 0.4 169 9 165 255 8.2 0 8.3 8.3 09/30/2005 04:00:00 1.3 0.4 2.3 0.4 1.1 0.5 1.9 0.4 0.6 0.4 1.9 0.4 154 10 155 255 8.1 0 8.3 8.3 09/30/2005 04:10:00 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 142 6 140 255 8.1 0 8.3 8 09/30/2005 04:20:00 1.3 0.3 1.9 0.4 1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 143 7 139 255 8.1 0 8.3 8 09/30/2005 04:30:00 1.4 0.4 2.3 0.4 1.3 0.3 1.9 0.4 0.8 0.3 1.5 0.4 169 5 175 255 8.1 0 8.3 8 09/30/2005 04:40:00 1.4 0.3 2.3 0.4 1.4 0.3 1.9 0.4 0.8 0.4 1.9 0.4 171 8 168 255 8 0 8.3 8 09/30/2005 04:50:00 1.4 0.4 2.6 0.4 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 185 9 201 255 8 0 8.3 8 09/30/2005 05:00:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 175 15 165 255 8 0 8 7.8 09/30/2005 05:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 168 15 171 255 7.9 0 8 7.8 09/30/2005 05:20:00 1.4 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 145 12 146 255 7.8 0 8 7.8 09/30/2005 05:30:00 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 151 13 165 255 7.9 0 8 7.8 09/30/2005 05:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 77 39 140 255 7.9 0 8 7.8 09/30/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 42 0 42 255 7.8 0 8 7.8 09/30/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 255 255 7.8 0 7.8 7.8 09/30/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 255 255 7.8 0 7.8 7.8 09/30/2005 06:20:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 42 0 42 255 7.8 0 7.8 7.8 09/30/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 255 255 7.7 0 7.8 7.5 09/30/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 42 0 255 255 7.6 0 7.8 7.5 09/30/2005 06:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 75 18 86 255 7.6 0 7.8 7.5 09/30/2005 07:00:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 94 13 113 255 7.6 0 7.8 7.5 09/30/2005 07:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 0 113 255 7.4 0 7.5 7.3 09/30/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 0 113 255 7.4 0 7.5 7.3 09/30/2005 07:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 0 113 255 7.3 0 7.5 7.3 09/30/2005 07:40:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 112 8 113 255 7.3 0 7.5 7.3 09/30/2005 07:50:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 101 8 109 255 7.3 0 7.3 7.3 09/30/2005 08:00:00 1.2 0.3 1.9 0.4 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 113 6 110 255 7.3 0 7.3 7.3 09/30/2005 08:10:00 0.9 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 116 2 113 255 7.3 0 7.3 7.3 09/30/2005 08:20:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 89 9 90 255 7.3 0 7.3 7.3 09/30/2005 08:30:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 71 23 34 255 7.3 0 7.5 7.3 09/30/2005 08:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 0 88 255 7.3 0 7.5 7.3 09/30/2005 08:50:00 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.6 0.4 1.9 0.4 75 11 59 255 7.3 0 7.3 7 09/30/2005 09:00:00 1.2 0.5 2.3 0.4 1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 74 13 50 255 6.9 0.1 7.3 6.7 09/30/2005 09:10:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 79 15 54 255 6.7 0 6.7 6.5 09/30/2005 09:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 54 17 42 255 6.4 0 6.5 6.2 09/30/2005 09:30:00 1.2 0.5 2.3 0.4 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 84 15 83 255 6.2 0 6.5 6.2 09/30/2005 09:40:00 1.1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 88 8 101 255 6.3 0 6.5 6.2 09/30/2005 09:50:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.5 0.2 1.5 0.4 89 5 88 255 6.6 0 6.7 6.2 09/30/2005 10:00:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 111 15 91 255 6.9 0 7.3 6.7 09/30/2005 10:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 103 0 104 255 7.4 0.1 7.8 7 09/30/2005 10:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 103 0 103 255 8 0 8.3 7.8 09/30/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 103 0 255 255 8.4 0.1 8.8 8.3 09/30/2005 10:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 99 6 102 255 9.2 0 9.6 8.8 09/30/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 0 255 255 9.4 0 9.6 9.3 09/30/2005 11:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 70 26 88 255 9.6 0 9.8 9.6 09/30/2005 11:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 33 0 33 255 9.7 0 9.8 9.6 09/30/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 33 0 255 255 10 0 10.3 9.8 09/30/2005 11:30:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 43 13 61 255 10.2 0 10.3 10.1 09/30/2005 11:40:00 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 41 8 19 255 10.5 0 10.9 10.3 09/30/2005 11:50:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 21 9 30 255 10.7 0 10.9 10.6 09/30/2005 12:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 337 13 7 255 10.9 0 11.1 10.9 09/30/2005 12:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 87 28 104 255 11.3 0.1 11.7 10.9 09/30/2005 12:20:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 105 35 90 255 11.6 0 11.7 11.4 09/30/2005 12:30:00 1.1 0.6 3 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 273 98 309 255 11.8 0 11.9 11.7 09/30/2005 12:40:00 2.1 0.7 3.4 0.4 2.1 0.6 3.4 0.7 1.8 0.7 3.4 0.4 331 20 334 255 12.1 0 12.2 11.9 09/30/2005 12:50:00 2.5 0.6 4.2 1.1 2.1 0.6 3.8 0.7 2.1 0.8 3.4 0.4 335 12 7 255 11.9 0.1 12.2 11.9 09/30/2005 13:00:00 1.5 0.6 3 0.4 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 335 24 321 255 11.8 0 11.9 11.7 09/30/2005 13:10:00 1.1 0.6 3 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.6 0.4 334 30 290 255 12.1 0.1 12.5 11.9 09/30/2005 13:20:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.8 0.6 2.6 0.4 346 24 294 255 12.4 0 12.5 12.2 09/30/2005 13:30:00 1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 262 26 243 255 12.3 0 12.5 11.9 09/30/2005 13:40:00 1.8 0.7 3.4 0.4 1.8 0.6 3 0.4 1.4 0.7 3 0.4 304 35 347 255 13.1 0.3 13.5 12.2 09/30/2005 13:50:00 2.4 0.6 3.8 0.7 2.3 0.6 3.8 0.4 1.6 0.8 3.4 0.4 318 33 291 255 13.7 0.2 14.1 13.3 09/30/2005 14:00:00 2.3 0.9 4.6 0.4 2.4 0.8 4.6 0.4 2 0.7 3.8 0.4 278 20 280 255 14.3 0 14.9 14.1 09/30/2005 14:10:00 2.7 0.9 4.9 0.7 2.8 0.8 4.9 1.1 2.3 1 4.9 0.4 299 27 288 255 14.6 0 15.2 14.4 09/30/2005 14:20:00 4 0.8 5.3 1.1 4 0.8 5.3 0.7 3.3 0.9 5.3 0.7 296 13 306 255 13.9 0.2 14.6 13.3 09/30/2005 14:30:00 3.4 0.7 5.3 1.5 3.4 0.7 5.7 1.5 2.9 0.8 5.3 1.1 306 16 285 255 13.5 0 13.8 13.3 09/30/2005 14:40:00 2.7 1.1 4.9 0.4 2.7 1.1 4.9 0.4 2.2 1.2 4.9 0.4 293 21 281 255 13.3 0 13.8 13 09/30/2005 14:50:00 3.1 1 4.9 0.4 3.2 1 5.3 0.4 2.5 1 4.6 0.4 291 23 259 255 13.1 0.2 13.5 12.7 09/30/2005 15:00:00 2.8 1.1 4.9 0.4 2.7 1.1 4.9 0.4 2.3 1.2 5.3 0.4 288 22 300 255 12.7 0 13.3 12.5 09/30/2005 15:10:00 2.3 1 4.6 0.4 2.2 1 4.6 0.4 1.7 1 3.8 0.4 296 38 294 255 12.5 0 12.7 12.2 09/30/2005 15:20:00 2 0.8 4.2 0.4 2 0.8 3.8 0.4 1.5 0.9 3.8 0.4 302 21 306 255 12.7 0 13.3 12.5 09/30/2005 15:30:00 2.7 0.7 4.6 0.7 2.6 0.7 4.2 0.4 2.2 0.8 3.8 0.4 294 20 304 255 12.5 0 12.7 12.2 09/30/2005 15:40:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.3 0.8 3 0.4 274 41 297 255 12.4 0 12.7 12.2 09/30/2005 15:50:00 2.4 0.9 4.2 0.4 2.4 0.9 4.6 0.4 2.2 0.9 4.2 0.4 290 24 289 255 12.3 0.1 12.5 11.9 09/30/2005 16:00:00 2.2 0.9 4.6 0.4 2.2 0.9 4.6 0.4 1.6 0.9 3.8 0.4 289 29 270 255 11.9 0 12.2 11.7 09/30/2005 16:10:00 3.3 0.8 5.3 1.1 3.3 0.8 4.9 1.1 2.6 1 4.9 0.4 301 15 261 255 12 0 12.2 11.9 09/30/2005 16:20:00 3 1 4.9 0.7 2.9 1 4.9 0.4 2.5 1.1 5.3 0.4 294 20 299 255 12.2 0 12.2 11.9 09/30/2005 16:30:00 3.4 0.8 5.7 1.1 3.4 0.8 6.1 1.5 2.8 1 5.7 0.4 287 19 288 255 12.1 0 12.2 11.9 09/30/2005 16:40:00 2.5 0.8 5.3 0.7 2.5 0.9 5.3 0.7 1.9 0.8 4.6 0.4 289 18 275 255 12.2 0 12.2 11.9 09/30/2005 16:50:00 2.7 1 5.3 0.7 2.7 1 5.3 1.1 2 1.1 5.3 0.4 289 23 293 255 11.7 0 12.2 11.7 09/30/2005 17:00:00 2 0.8 4.2 0.4 2 0.8 4.6 0.4 1.3 0.8 3.4 0.4 286 20 262 255 11.4 0 11.7 11.4 09/30/2005 17:10:00 1.8 0.9 4.2 0.4 1.8 0.9 4.2 0.4 1.3 0.8 3.4 0.4 278 16 280 255 11.2 0 11.4 11.1 09/30/2005 17:20:00 1.7 0.8 3 0.4 1.6 0.8 3.4 0.4 1.1 0.7 3 0.4 278 20 271 255 11.1 0 11.1 10.9 09/30/2005 17:30:00 0.8 0.6 2.6 0.4 0.8 0.7 2.6 0.4 0.5 0.3 1.9 0.4 268 22 271 255 10.9 0 11.1 10.6 09/30/2005 17:40:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.4 2.6 0.4 280 12 303 255 10.6 0 10.9 10.6 09/30/2005 17:50:00 1.2 0.6 3 0.4 1.2 0.6 2.6 0.4 0.8 0.5 1.9 0.4 291 16 288 255 10.3 0.1 10.6 10.3 09/30/2005 18:00:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1 0.6 2.3 0.4 300 15 277 255 10.1 0 10.3 9.8 09/30/2005 18:10:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.5 1.9 0.4 301 12 310 255 9.8 0 10.1 9.8 09/30/2005 18:20:00 1.2 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.6 0.3 1.5 0.4 305 5 306 255 9.7 0 9.8 9.6 09/30/2005 18:30:00 0.9 0.4 1.9 0.4 0.9 0.3 1.5 0.4 0.4 0.2 1.5 0.4 296 8 304 255 9.4 0 9.6 9.3 09/30/2005 18:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 314 8 303 255 9.3 0 9.3 9 09/30/2005 18:50:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 307 19 299 255 9 0 9.3 9 09/30/2005 19:00:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 282 8 291 255 8.9 0 9 8.8 09/30/2005 19:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.2 1.1 0.4 307 24 293 255 8.6 0 8.8 8.5 09/30/2005 19:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 323 28 355 255 8.4 0 8.5 8.5 09/30/2005 19:30:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 315 0 315 255 8.3 0 8.5 8.3 09/30/2005 19:40:00 0.6 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 345 33 315 255 8.3 0 8.5 8.3 09/30/2005 19:50:00 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 22 0 22 255 8.3 0 8.5 8.3 09/30/2005 20:00:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 0.6 0.3 1.1 0.4 22 0 22 255 8.1 0 8.3 8.3 09/30/2005 20:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.4 0.1 0.7 0.4 23 1 22 255 8.2 0 8.3 8.3 09/30/2005 20:20:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 24 0 24 255 8.1 0.1 8.3 7.8 09/30/2005 20:30:00 0.9 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 24 0 24 255 7.8 0 8 7.8 09/30/2005 20:40:00 0.7 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 24 0 24 255 7.7 0 7.8 7.5 09/30/2005 20:50:00 1.2 0.4 1.9 0.4 1 0.5 1.9 0.4 0.5 0.2 1.5 0.4 30 8 30 255 7.4 0 7.5 7.3 09/30/2005 21:00:00 1.7 0.3 2.3 0.4 1.6 0.3 2.3 0.4 0.9 0.3 1.9 0.4 53 7 51 255 7.3 0 7.5 7.3 09/30/2005 21:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.9 0.4 1.9 0.4 41 8 37 255 7 0.1 7.3 6.7 09/30/2005 21:20:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 33 2 36 255 6.7 0 7 6.7 09/30/2005 21:30:00 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 0.7 0.4 1.5 0.4 28 3 28 255 6.7 0 7 6.7 09/30/2005 21:40:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1 0.4 2.3 0.4 33 8 33 255 6.9 0 7 6.7 09/30/2005 21:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 38 2 34 255 6.7 0 7 6.7 09/30/2005 22:00:00 1.4 0.5 2.6 0.7 1.4 0.5 2.6 0.4 0.6 0.4 1.9 0.4 47 8 39 255 7 0.1 7.3 6.7 09/30/2005 22:10:00 2 0.6 3.4 0.4 2 0.6 3.8 0.4 1.2 0.6 3 0.4 54 11 47 255 7.5 0.1 7.8 7.3 09/30/2005 22:20:00 2.7 0.6 4.2 1.1 2.7 0.5 4.2 1.1 2.1 0.6 3.8 0.4 47 11 43 255 8.1 0 8.5 7.8 09/30/2005 22:30:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.2 0.6 3.4 0.7 41 11 52 255 8.3 0 8.5 8.3 09/30/2005 22:40:00 3.5 0.6 4.9 1.5 3.4 0.6 4.9 1.5 2.8 0.7 4.6 0.7 36 12 33 255 8.1 0 8.3 8 09/30/2005 22:50:00 3.2 0.6 4.9 1.9 3.2 0.6 4.9 1.9 2.6 0.7 4.2 1.1 47 13 53 255 8 0 8.3 7.8 09/30/2005 23:00:00 2.6 0.7 4.2 0.4 2.6 0.7 4.2 1.1 2.1 0.6 3.4 0.4 63 13 42 255 7.8 0 8 7.5 09/30/2005 23:10:00 3.1 0.8 4.9 1.5 3.1 0.8 4.9 1.5 2.4 0.8 4.6 0.7 55 15 39 255 7.5 0 7.8 7.3 09/30/2005 23:20:00 2.5 0.7 4.2 1.1 2.5 0.6 3.8 1.1 1.7 0.6 3.4 0.4 54 15 57 255 7.3 0 7.5 7.3 09/30/2005 23:30:00 2.1 0.7 3.8 0.7 2.2 0.7 3.8 0.7 1.6 0.7 3.8 0.4 61 13 53 255 7.3 0 7.3 7 09/30/2005 23:40:00 3.2 0.9 5.3 1.1 3.2 0.8 5.7 1.1 2.2 0.9 4.2 0.4 74 14 60 255 6.9 0.1 7.3 6.7 09/30/2005 23:50:00 3.5 0.6 5.7 1.5 3.4 0.6 5.7 1.5 2.7 0.6 4.2 0.7 59 13 39 255 7.1 0 7.3 7 10/01/2005 00:00:00 3.6 0.6 5.3 2.3 3.6 0.6 5.3 2.3 2.7 0.7 4.9 1.1 50 10 48 255 7.3 0 7.3 6.7 10/01/2005 00:10:00 3.2 0.6 4.9 1.9 3.1 0.6 4.6 1.5 2.3 0.7 4.2 0.7 50 10 44 255 7.3 0 7.3 7.3 10/01/2005 00:20:00 2.6 0.5 3.8 0.7 2.5 0.5 4.2 1.1 1.8 0.5 3 0.4 47 11 35 255 7.1 0.1 7.3 7 10/01/2005 00:30:00 2.3 0.4 3.4 1.1 2.1 0.4 3 1.1 1.4 0.5 2.6 0.4 45 11 77 255 6.7 0 7 6.7 10/01/2005 00:40:00 2 0.3 3 1.1 1.8 0.4 2.6 0.7 0.7 0.4 1.9 0.4 54 6 47 255 6.4 0.2 6.7 6 10/01/2005 00:50:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.5 1.3 0.5 2.6 0.4 68 8 62 255 5.4 0.2 6 5.2 10/01/2005 01:00:00 2.6 0.4 3.8 1.9 2.4 0.4 3.8 1.5 1.4 0.5 3 0.4 69 6 60 255 5.2 0 5.2 5 10/01/2005 01:10:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 1.1 0.5 0.2 1.1 0.4 49 8 66 255 5.1 0 5.2 5 10/01/2005 01:20:00 2 0.5 3.4 1.1 1.9 0.5 3 0.7 1 0.5 2.3 0.4 69 10 63 255 5.2 0 5.5 5 10/01/2005 01:30:00 2 0.5 3.4 1.1 1.7 0.5 3.4 0.7 0.9 0.5 2.6 0.4 66 11 71 255 5.4 0 5.5 5.2 10/01/2005 01:40:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.1 1.5 0.4 93 27 97 255 5.4 0 5.5 5.2 10/01/2005 01:50:00 2 0.5 3.8 0.7 1.8 0.5 3 0.4 1.1 0.5 2.3 0.4 98 14 112 255 5.2 0 5.5 5 10/01/2005 02:00:00 2.2 0.5 3.4 0.7 2 0.5 3.4 0.4 1.2 0.6 2.6 0.4 57 10 56 255 5.2 0 5.7 5 10/01/2005 02:10:00 3.5 0.8 5.7 1.9 3.4 0.9 5.7 1.5 2.5 0.8 4.6 0.4 49 18 40 255 5.6 0.2 6.2 5.2 10/01/2005 02:20:00 3.9 0.7 6.5 2.3 3.8 0.8 6.5 1.9 2.9 0.7 4.6 1.5 56 12 49 255 6.3 0.1 6.7 6.2 10/01/2005 02:30:00 4.2 0.8 6.1 2.3 4.2 0.8 6.5 2.3 3.1 0.8 5.3 1.1 59 12 46 255 6.9 0.1 7 6.7 10/01/2005 02:40:00 4.3 0.8 6.1 2.3 4.3 0.8 6.1 2.3 3.5 0.8 5.7 1.1 58 12 56 255 6.9 0 7 7 10/01/2005 02:50:00 4.3 0.6 5.7 3 4.3 0.6 5.7 2.6 3.4 0.7 5.3 1.5 49 10 46 255 6.8 0 7 6.7 10/01/2005 03:00:00 4.6 0.8 6.5 2.6 4.5 0.8 6.5 2.6 3.5 0.9 5.7 1.5 64 12 67 255 6.8 0 7 6.7 10/01/2005 03:10:00 3.9 1 6.5 1.9 3.8 1 6.1 1.5 3.2 0.9 5.3 1.1 66 13 73 255 7 0 7.3 7 10/01/2005 03:20:00 3.6 0.6 5.3 2.3 3.6 0.6 5.3 2.3 2.8 0.7 4.6 1.1 71 13 48 255 7.1 0 7.3 7 10/01/2005 03:30:00 3.2 0.9 5.3 0.7 3.1 0.9 5.3 0.7 2.3 0.8 4.9 0.7 65 11 71 255 7 0 7.3 7 10/01/2005 03:40:00 3.7 0.6 5.3 1.9 3.6 0.6 5.3 1.5 2.9 0.8 4.9 0.7 50 12 48 255 6.9 0 7 7 10/01/2005 03:50:00 3.4 1 5.7 1.1 3.3 1 5.7 1.1 2.6 0.9 4.9 0.4 45 12 56 255 7.1 0 7.3 7 10/01/2005 04:00:00 3.5 0.8 6.5 1.9 3.3 0.8 6.1 1.5 2.8 0.7 4.9 1.1 54 22 50 255 7.1 0 7.3 7 10/01/2005 04:10:00 3.6 0.6 5.3 2.3 3.5 0.6 5.3 1.9 2.7 0.7 4.2 0.7 70 10 80 255 6.8 0 7.3 6.5 10/01/2005 04:20:00 3.5 0.7 5.3 2.3 3.4 0.7 5.3 1.5 2.5 0.9 4.6 0.7 64 10 51 255 6.6 0 6.7 6.5 10/01/2005 04:30:00 3 0.8 4.9 1.5 3 0.9 4.9 1.1 2.1 1 4.6 0.4 77 12 85 255 6.7 0 7 6.5 10/01/2005 04:40:00 2.7 0.6 4.2 0.7 2.5 0.6 4.2 0.7 1.8 0.6 3.4 0.4 81 15 81 255 6.2 0 6.5 6 10/01/2005 04:50:00 3.5 0.7 4.9 1.5 3.4 0.8 4.9 1.1 2.7 0.9 4.9 0.4 81 11 57 255 5.7 0.1 6 5.5 10/01/2005 05:00:00 3.5 0.9 5.7 1.1 3.4 0.9 5.3 1.5 2.4 0.8 4.6 0.7 75 13 82 255 5.7 0 6 5.5 10/01/2005 05:10:00 2.3 0.9 4.9 0.4 2.2 1 4.9 0.4 1.2 0.9 3.8 0.4 60 21 71 255 5.9 0.2 6.2 5.5 10/01/2005 05:20:00 1.9 0.6 3.8 0.4 1.6 0.6 3.8 0.4 1 0.6 3.4 0.4 25 23 50 255 5.4 0.1 5.7 5 10/01/2005 05:30:00 1.7 0.6 3 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 336 13 340 255 4.8 0.2 5.2 4.3 10/01/2005 05:40:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0 0 0 255 4.1 0.1 4.5 4 10/01/2005 05:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 310 30 294 255 3.8 0 4.3 3.8 10/01/2005 06:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 314 11 306 255 3.6 0.1 4 3.5 10/01/2005 06:10:00 1.3 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.5 0.3 2.3 0.4 342 18 354 255 3.2 0.2 3.8 2.8 10/01/2005 06:20:00 1.7 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.5 0.3 1.5 0.4 26 32 9 255 2.8 0.1 3 2.6 10/01/2005 06:30:00 1.6 0.7 3 0.4 1.3 0.7 3 0.4 0.5 0.2 1.9 0.4 51 12 31 255 2.6 0 2.8 2.6 10/01/2005 06:40:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 48 17 62 255 2.9 0 2.8 2.6 10/01/2005 06:50:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 13 13 22 255 2.8 0 2.8 2.8 10/01/2005 07:00:00 0.7 0.5 2.3 0.4 0.5 0.3 2.3 0.4 0.4 0 0.4 0.4 357 6 25 255 2.9 0 3.3 2.8 10/01/2005 07:10:00 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 315 29 299 255 2.7 0 3 2.6 10/01/2005 07:20:00 1.5 0.6 2.6 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 357 35 290 255 2.9 0 3.3 2.8 10/01/2005 07:30:00 1.5 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 60 10 66 255 2.8 0 2.8 2.6 10/01/2005 07:40:00 1.5 0.7 3 0.4 1.3 0.7 2.6 0.4 0.6 0.5 2.3 0.4 60 15 53 255 2.9 0 3.3 2.8 10/01/2005 07:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 39 255 3.2 0 3.5 3.3 10/01/2005 08:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 6 15 39 255 3.5 0 3.8 3.3 10/01/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 255 255 3.6 0 4 3.5 10/01/2005 08:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 359 0 359 255 3.8 0 4 3.8 10/01/2005 08:30:00 0.9 0.6 2.3 0.4 0.6 0.5 1.9 0.4 0.5 0.4 1.9 0.4 221 51 206 255 4.3 0.2 4.8 3.8 10/01/2005 08:40:00 1.2 0.7 2.6 0.4 1.1 0.7 2.3 0.4 0.8 0.5 2.3 0.4 210 12 196 255 4.9 0.1 5.2 4.5 10/01/2005 08:50:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 181 6 194 255 5.6 0.2 6 5 10/01/2005 09:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 165 20 181 255 6.3 0.2 6.7 6 10/01/2005 09:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 166 30 200 255 7.1 0.2 7.5 6.7 10/01/2005 09:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 168 24 196 255 7.9 0.1 8.3 7.5 10/01/2005 09:30:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 130 35 124 255 8.3 0.2 8.8 8 10/01/2005 09:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 156 255 8.9 0 9 8.5 10/01/2005 09:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 259 56 309 255 9.6 0.3 10.1 9 10/01/2005 10:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 189 32 223 255 10.2 0 10.6 9.8 10/01/2005 10:10:00 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 191 26 208 255 10.3 0.2 10.6 10.1 10/01/2005 10:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 88 33 101 255 10.7 0 11.1 10.6 10/01/2005 10:30:00 0.9 0.6 3 0.4 0.7 0.5 3 0.4 0.7 0.6 3 0.4 179 45 242 255 11.1 0.1 11.4 10.9 10/01/2005 10:40:00 0.9 0.6 2.6 0.4 0.7 0.4 2.6 0.4 0.7 0.5 2.3 0.4 211 30 205 255 10.7 0 11.1 10.6 10/01/2005 10:50:00 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 230 41 255 255 10.5 0 10.6 10.3 10/01/2005 11:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 269 36 317 255 10.6 0 10.9 10.6 10/01/2005 11:10:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 260 56 326 255 10.8 0.1 11.1 10.6 10/01/2005 11:20:00 0.9 0.6 2.6 0.4 0.7 0.6 3 0.4 0.6 0.5 2.3 0.4 218 51 197 255 11 0 11.1 10.9 10/01/2005 11:30:00 1.4 0.7 3 0.4 1.3 0.8 3 0.4 1 0.6 2.6 0.4 235 15 214 255 11 0 11.1 10.9 10/01/2005 11:40:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 232 30 186 255 11.1 0 11.1 10.9 10/01/2005 11:50:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 247 21 253 255 11.1 0 11.4 11.1 10/01/2005 12:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 288 36 273 255 11.1 0.1 11.4 10.9 10/01/2005 12:10:00 1 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.7 0.5 2.6 0.4 313 24 288 255 10.9 0 11.1 10.9 10/01/2005 12:20:00 0.8 0.6 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 260 22 238 255 11.1 0 11.4 11.1 10/01/2005 12:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 2.3 0.4 253 1 253 255 11.3 0.1 11.7 11.1 10/01/2005 12:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 301 24 337 255 11.7 0 11.9 11.7 10/01/2005 12:50:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 299 45 321 255 11.8 0 11.9 11.7 10/01/2005 13:00:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 313 38 10 255 12 0 12.2 11.9 10/01/2005 13:10:00 1 0.6 2.6 0.4 0.7 0.6 2.3 0.4 0.6 0.5 2.3 0.4 357 30 3 255 11.9 0 12.2 11.7 10/01/2005 13:20:00 1.5 0.7 3 0.4 1.2 0.8 2.6 0.4 1 0.6 2.6 0.4 51 17 51 255 11.9 0 12.2 11.9 10/01/2005 13:30:00 1.7 0.6 3 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 22 26 347 255 11.9 0.1 12.2 11.7 10/01/2005 13:40:00 1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 33 11 62 255 11.8 0 11.9 11.7 10/01/2005 13:50:00 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 347 24 314 255 12.2 0 12.2 11.9 10/01/2005 14:00:00 1.2 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.7 0.3 1.5 0.4 31 13 35 255 12.3 0 12.2 11.9 10/01/2005 14:10:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 359 22 351 255 12.3 0 12.5 12.2 10/01/2005 14:20:00 1.8 0.5 3 0.4 1.4 0.6 2.6 0.4 1.4 0.5 2.6 0.4 71 23 53 255 12.4 0 12.5 12.2 10/01/2005 14:30:00 1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 35 45 11 255 12.3 0 12.5 12.2 10/01/2005 14:40:00 1.5 0.8 3 0.4 1.1 0.9 3 0.4 0.8 0.6 3 0.4 358 17 337 255 12.3 0 12.2 12.2 10/01/2005 14:50:00 2.2 0.4 3.4 1.1 1.9 0.5 3.4 0.4 1.2 0.7 3.4 0.4 2 7 353 255 12.3 0 12.2 12.2 10/01/2005 15:00:00 1.8 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 13 14 357 255 12 0 12.2 11.7 10/01/2005 15:10:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 10 12 4 255 11.8 0 11.9 11.7 10/01/2005 15:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 30 4 35 255 11.7 0 11.7 11.7 10/01/2005 15:30:00 0.6 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.4 0.3 1.5 0.4 10 36 311 255 11.7 0 11.7 11.7 10/01/2005 15:40:00 1 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.5 0.4 287 11 321 255 11.5 0 11.7 11.4 10/01/2005 15:50:00 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 302 0 302 255 11.3 0 11.4 11.1 10/01/2005 16:00:00 1.4 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 298 8 303 255 10.9 0 11.1 10.9 10/01/2005 16:10:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 271 0 273 255 10.6 0 10.9 10.6 10/01/2005 16:20:00 1.3 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 301 12 307 255 10.5 0 10.6 10.6 10/01/2005 16:30:00 1.3 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 301 7 314 255 10.3 0 10.6 10.1 10/01/2005 16:40:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 304 17 16 255 10.1 0 10.3 10.1 10/01/2005 16:50:00 1.2 0.2 1.9 0.7 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 15 0 15 255 10 0 10.1 9.8 10/01/2005 17:00:00 1.5 0.3 2.3 0.7 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 3 13 342 255 9.6 0 9.8 9.3 10/01/2005 17:10:00 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 342 5 343 255 9.2 0 9.6 9 10/01/2005 17:20:00 1.6 0.3 2.3 1.1 1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 352 7 346 255 9 0 9.3 9 10/01/2005 17:30:00 1.3 0.4 2.3 0.7 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 351 7 345 255 8.9 0 9 8.8 10/01/2005 17:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 346 0 346 255 8.7 0 8.8 8.5 10/01/2005 17:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 347 0 347 255 8.5 0 8.8 8.3 10/01/2005 18:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 0 347 255 8.4 0 8.5 8.3 10/01/2005 18:10:00 0.5 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 2 28 56 255 8.1 0.1 8.5 8 10/01/2005 18:20:00 2.2 0.4 3 1.1 2.1 0.5 3 0.7 1.5 0.4 2.3 0.7 75 4 73 255 7.8 0 8.3 7.8 10/01/2005 18:30:00 2.3 0.4 3.4 1.5 2.2 0.4 3 1.1 1.3 0.5 2.3 0.4 83 5 80 255 7.6 0 7.8 7.5 10/01/2005 18:40:00 1.8 0.3 2.6 1.1 1.6 0.3 2.6 0.7 0.7 0.3 1.5 0.4 88 4 83 255 7.4 0 7.5 7.3 10/01/2005 18:50:00 1.9 0.3 2.3 1.1 1.7 0.3 2.3 0.7 0.7 0.3 1.1 0.4 87 3 88 255 7.6 0 7.8 7.5 10/01/2005 19:00:00 1.6 0.2 2.3 1.1 1.5 0.2 2.3 0.7 0.6 0.3 1.1 0.4 95 8 84 255 7.6 0 7.8 7.5 10/01/2005 19:10:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 108 3 95 255 7.8 0 7.8 7.8 10/01/2005 19:20:00 1.4 0.6 2.3 0.4 1.2 0.5 1.9 0.4 0.8 0.3 1.5 0.4 139 13 146 255 7.8 0 7.8 7.5 10/01/2005 19:30:00 1.7 0.4 2.6 0.7 1.4 0.5 2.6 0.4 0.7 0.4 1.9 0.4 129 13 104 255 7.6 0 7.8 7.5 10/01/2005 19:40:00 2 0.3 2.6 1.1 1.7 0.4 2.6 0.4 0.8 0.4 1.9 0.4 105 9 102 255 7.6 0 7.8 7.5 10/01/2005 19:50:00 2.4 0.3 3.4 1.9 2.2 0.3 3.4 1.5 1.3 0.4 2.3 0.4 89 5 84 255 7.4 0 7.5 7.3 10/01/2005 20:00:00 2.3 0.4 3 1.1 2.2 0.4 3 0.7 1.3 0.5 2.6 0.4 107 10 93 255 7.2 0 7.3 7 10/01/2005 20:10:00 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 147 27 111 255 6.8 0 7 6.7 10/01/2005 20:20:00 2.2 0.5 3 1.1 2.2 0.4 3 1.1 1.5 0.5 2.6 0.4 188 9 197 255 6.6 0 6.7 6.5 10/01/2005 20:30:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 0.8 0.5 1.9 0.4 148 19 162 255 6.4 0 6.7 6.2 10/01/2005 20:40:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.5 0.3 1.5 0.4 116 10 102 255 6.1 0 6.2 5.7 10/01/2005 20:50:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.6 0.2 1.1 0.4 122 6 118 255 5.7 0 6 5.7 10/01/2005 21:00:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 0.6 0.3 1.5 0.4 111 3 111 255 5.7 0 5.7 5.7 10/01/2005 21:10:00 1.8 0.5 3 0.7 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 118 21 142 255 5.8 0 6 5.7 10/01/2005 21:20:00 1.8 0.7 3 0.4 1.6 0.7 3 0.4 1.2 0.7 3 0.4 124 15 120 255 6.1 0 6.2 6 10/01/2005 21:30:00 0.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 0.6 0.5 1.9 0.4 66 58 102 255 6.2 0 6.5 6.2 10/01/2005 21:40:00 2.4 1.2 5.7 0.4 2.1 1.3 5.3 0.4 1.5 1 4.2 0.4 290 11 318 255 6.2 0 6.5 6.2 10/01/2005 21:50:00 4 1.2 6.5 1.1 3.8 1.2 6.5 1.1 3.1 1.2 6.1 0.4 296 14 265 255 6.7 0.3 7.3 6.2 10/01/2005 22:00:00 3.3 1.3 7.6 0.7 3.2 1.4 7.2 0.7 2.3 1.3 5.7 0.4 285 22 273 255 7.3 0 7.3 7 10/01/2005 22:10:00 3.2 1.2 6.1 0.7 3.1 1.2 6.1 1.1 2.4 1.1 5.3 0.4 279 18 256 255 7.1 0 7.3 7 10/01/2005 22:20:00 3.4 1 5.3 0.4 3.2 1 5.7 0.4 2 0.9 4.2 0.4 268 19 257 255 6.8 0 7 6.7 10/01/2005 22:30:00 3.2 0.8 4.9 0.7 3.1 0.8 4.9 1.1 1.9 0.9 4.6 0.4 257 20 237 255 6.7 0 6.7 6.5 10/01/2005 22:40:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.6 0.7 3.4 0.4 257 12 251 255 6.5 0 6.7 6.5 10/01/2005 22:50:00 2.9 0.7 4.9 1.1 2.9 0.8 4.9 1.1 1.7 0.8 3.8 0.4 244 18 255 255 6.4 0 6.5 6.2 10/01/2005 23:00:00 2.6 1 4.6 0.7 2.4 1 4.2 0.4 1.6 1 3.8 0.4 241 22 237 255 6.2 0 6.5 6.2 10/01/2005 23:10:00 2.5 0.8 4.9 1.1 2.4 0.8 4.6 0.4 1.5 0.8 3.8 0.4 259 22 253 255 6.1 0 6.2 6 10/01/2005 23:20:00 1.6 1 3.8 0.4 1.5 1 3.8 0.4 0.8 0.6 2.6 0.4 212 56 256 255 5.8 0 6 5.7 10/01/2005 23:30:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.4 1.9 0.4 291 30 266 255 5.6 0 5.7 5.5 10/01/2005 23:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 327 15 288 255 5.6 0 5.7 5.5 10/01/2005 23:50:00 1.2 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 351 13 333 255 5.5 0 5.7 5.5 10/02/2005 00:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 349 15 21 255 5.4 0 5.5 5.5 10/02/2005 00:10:00 1.3 0.3 1.9 0.4 1.3 0.3 1.9 0.7 0.6 0.3 1.5 0.4 357 6 1 255 5.4 0 5.5 5.5 10/02/2005 00:20:00 1.2 0.4 1.9 0.4 1 0.5 1.9 0.4 0.4 0.2 1.1 0.4 354 2 355 255 5.4 0 5.5 5.5 10/02/2005 00:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 349 12 317 255 5.3 0 5.5 5.2 10/02/2005 00:40:00 1.4 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.5 0.2 1.5 0.4 318 3 318 255 5.2 0 5.5 5 10/02/2005 00:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.9 0.4 335 6 318 255 5.1 0 5.2 5 10/02/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 339 0 255 255 5.1 0 5.2 5 10/02/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 29 255 255 5.1 0 5.2 5 10/02/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 133 0 255 255 5.1 0 5 5 10/02/2005 01:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 133 0 133 255 5.1 0 5.2 5 10/02/2005 01:40:00 0.8 0.3 1.5 0.4 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 135 0 134 255 5.1 0 5.2 5 10/02/2005 01:50:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 140 7 151 255 5.1 0 5.2 5 10/02/2005 02:00:00 1.6 0.3 2.3 0.7 1.4 0.3 1.9 0.4 0.8 0.3 1.9 0.4 154 7 149 255 5.1 0 5.2 5 10/02/2005 02:10:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 137 8 127 255 5.1 0 5.2 5 10/02/2005 02:20:00 1.6 0.4 2.6 0.4 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 132 8 146 255 5.1 0 5 5 10/02/2005 02:30:00 1.3 0.4 1.9 0.4 1.1 0.3 1.9 0.4 0.5 0.3 1.5 0.4 127 4 131 255 5.1 0 5 5 10/02/2005 02:40:00 1.2 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 131 5 126 255 5.1 0 5 5 10/02/2005 02:50:00 1.1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 156 13 160 255 5.1 0 5 5 10/02/2005 03:00:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 164 0 164 255 5.1 0 5 5 10/02/2005 03:10:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 164 0 164 255 5.1 0 5 5 10/02/2005 03:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 164 255 5.1 0 5.2 5 10/02/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 255 255 5.1 0 5.2 5 10/02/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 255 255 5.1 0 5.2 5 10/02/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 255 255 5.1 0 5.2 5 10/02/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 255 255 5.1 0 5.2 5 10/02/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 53 255 255 5.2 0 5.5 5 10/02/2005 04:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 36 255 5.2 0 5.5 5.2 10/02/2005 04:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 36 0 36 255 5.2 0 5.5 5.2 10/02/2005 04:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 36 0 36 255 5.2 0 5.5 5.2 10/02/2005 04:50:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 42 7 36 255 5.2 0 5.5 5.2 10/02/2005 05:00:00 1.2 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.1 0.4 40 5 36 255 5.4 0 5.5 5.5 10/02/2005 05:10:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 39 0 40 255 5.4 0 5.5 5.5 10/02/2005 05:20:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 39 0 39 255 5.4 0 5.7 5.5 10/02/2005 05:30:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 39 0 39 255 5.5 0 5.7 5.5 10/02/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 255 255 5.4 0 5.7 5.5 10/02/2005 05:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 42 2 43 255 5.4 0 5.5 5.5 10/02/2005 06:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 43 0 43 255 5.4 0 5.5 5.5 10/02/2005 06:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 2 43 255 5.4 0 5.5 5.5 10/02/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 5.4 0 5.5 5.5 10/02/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 5.4 0 5.5 5.2 10/02/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 51 255 255 5.4 0 5.5 5.5 10/02/2005 06:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 149 0 148 255 5.4 0 5.5 5.5 10/02/2005 07:00:00 0.9 0.4 1.5 0.4 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 145 4 148 255 5.4 0 5.5 5.5 10/02/2005 07:10:00 1.1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 120 13 112 255 5.5 0 5.7 5.5 10/02/2005 07:20:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 111 3 111 255 5.6 0 5.7 5.5 10/02/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 5.6 0 5.7 5.5 10/02/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 5.6 0 5.7 5.7 10/02/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 5.7 0 5.7 5.7 10/02/2005 08:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 111 255 5.7 0 5.7 5.7 10/02/2005 08:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 111 255 5.8 0 6 5.7 10/02/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 5.9 0 6 5.7 10/02/2005 08:30:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 67 35 35 255 6.1 0 6.2 6 10/02/2005 08:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 35 0 35 255 6.1 0 6.2 6 10/02/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 2 255 255 6.2 0 6.2 6 10/02/2005 09:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 2 44 255 6.2 0 6.5 6.2 10/02/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 255 255 6.6 0 6.7 6.2 10/02/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 255 255 6.8 0 7 6.7 10/02/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 255 255 6.9 0 7 6.7 10/02/2005 09:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 44 255 6.9 0 7 6.7 10/02/2005 09:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 44 0 44 255 6.9 0 7 7 10/02/2005 10:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 23 12 16 255 7.2 0 7.3 7 10/02/2005 10:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 16 0 16 255 7.3 0 7.5 7.3 10/02/2005 10:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 38 9 34 255 7.6 0 7.8 7.5 10/02/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 20 38 255 255 7.8 0 8 7.5 10/02/2005 10:40:00 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.5 0.4 2.3 0.4 267 41 209 255 8 0 8.3 7.8 10/02/2005 10:50:00 1.2 0.9 3.4 0.4 1 0.8 3 0.4 0.7 0.6 3 0.4 261 24 258 255 8.1 0 8.3 8 10/02/2005 11:00:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 282 18 265 255 8 0 8.3 7.8 10/02/2005 11:10:00 1.6 0.5 3 0.4 1.2 0.6 2.6 0.4 0.8 0.5 2.3 0.4 272 19 273 255 7.8 0 8 7.8 10/02/2005 11:20:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 287 21 270 255 8 0 8.3 7.8 10/02/2005 11:30:00 1.2 0.7 3 0.4 1 0.6 3 0.4 0.7 0.5 2.6 0.4 284 27 301 255 8.2 0 8.5 8 10/02/2005 11:40:00 1.7 0.6 3 0.4 1.4 0.7 3.4 0.4 1.1 0.8 3 0.4 282 16 295 255 8.5 0 8.8 8.5 10/02/2005 11:50:00 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.6 0.4 260 21 264 255 8.4 0 8.5 8.3 10/02/2005 12:00:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 258 51 281 255 8.6 0 8.8 8.5 10/02/2005 12:10:00 1.3 0.6 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 219 45 253 255 8.5 0 8.8 8.5 10/02/2005 12:20:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 155 15 121 255 8.1 0.1 8.5 8 10/02/2005 12:30:00 1.7 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.3 0.7 2.6 0.4 147 13 140 255 7.9 0 8 7.8 10/02/2005 12:40:00 1.7 0.4 2.6 0.7 1.3 0.4 2.3 0.4 1.2 0.5 2.6 0.4 145 12 147 255 7.8 0 7.8 7.8 10/02/2005 12:50:00 1.4 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 143 7 143 255 8 0 8.3 7.8 10/02/2005 13:00:00 1.2 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.9 0.4 141 10 155 255 8.3 0.1 8.5 8 10/02/2005 13:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 140 30 108 255 8.9 0.2 9.6 8.5 10/02/2005 13:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 196 66 218 255 9.5 0 9.6 9.6 10/02/2005 13:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 17 6 28 255 9.6 0 9.8 9.6 10/02/2005 13:40:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 346 12 330 255 9.5 0 9.6 9.3 10/02/2005 13:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 13 22 339 255 9.2 0.1 9.6 9 10/02/2005 14:00:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 23 0 24 255 9 0 9.3 9 10/02/2005 14:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 23 5 24 255 9 0 9 9 10/02/2005 14:20:00 1.7 0.3 2.3 0.7 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 347 11 349 255 9.1 0 9.3 9 10/02/2005 14:30:00 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.6 0.4 2.3 0.4 351 11 352 255 9.3 0 9.6 9 10/02/2005 14:40:00 1.7 0.3 2.6 0.7 1.2 0.4 2.3 0.4 0.8 0.5 2.3 0.4 354 14 11 255 9.3 0 9.6 9 10/02/2005 14:50:00 1.5 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 351 5 355 255 9.2 0 9.3 9 10/02/2005 15:00:00 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 348 3 347 255 9.3 0 9.6 9.3 10/02/2005 15:10:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 350 6 340 255 9.5 0 9.6 9.3 10/02/2005 15:20:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 0 13 28 255 9.6 0 9.8 9.6 10/02/2005 15:30:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 26 6 14 255 9.8 0 9.8 9.6 10/02/2005 15:40:00 1.2 0.3 1.9 0.7 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 28 10 27 255 9.7 0 9.8 9.6 10/02/2005 15:50:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 7 8 22 255 9.5 0 9.6 9.3 10/02/2005 16:00:00 1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0 7 4 255 9.4 0 9.6 9.3 10/02/2005 16:10:00 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 342 7 0 255 9.2 0 9.3 9 10/02/2005 16:20:00 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 347 11 342 255 9.2 0 9.3 9 10/02/2005 16:30:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 356 0 357 255 9.2 0 9.3 9.3 10/02/2005 16:40:00 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 12 6 16 255 9.2 0 9.3 9 10/02/2005 16:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 9 0 9 255 9.2 0 9.3 9.3 10/02/2005 17:00:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 18 1 18 255 9.1 0 9.3 9 10/02/2005 17:10:00 1 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 18 0 18 255 9 0 9 9 10/02/2005 17:20:00 1.1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 2 9 345 255 8.9 0 9 8.8 10/02/2005 17:30:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0 5 358 255 8.7 0 8.8 8.5 10/02/2005 17:40:00 1.2 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.5 0.3 1.1 0.4 18 7 22 255 8.5 0 8.8 8.5 10/02/2005 17:50:00 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 0.9 0.6 2.3 0.4 28 8 25 255 8.3 0 8.5 8 10/02/2005 18:00:00 1.9 0.3 2.6 1.1 1.5 0.4 2.3 0.7 0.9 0.5 1.9 0.4 39 9 41 255 8 0 8.3 8 10/02/2005 18:10:00 1.1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.5 0.3 1.5 0.4 25 5 25 255 7.8 0 8 7.5 10/02/2005 18:20:00 1.4 0.3 2.3 0.7 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 41 14 34 255 7.4 0 7.5 7.3 10/02/2005 18:30:00 1.3 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 37 9 25 255 7.2 0 7.3 7 10/02/2005 18:40:00 1.1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 49 3 38 255 7 0 7.3 7 10/02/2005 18:50:00 1.3 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 49 4 50 255 6.9 0 7 6.7 10/02/2005 19:00:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.5 0.2 1.1 0.4 48 5 53 255 6.9 0 7 7 10/02/2005 19:10:00 1.3 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 57 10 66 255 7 0 7.3 7 10/02/2005 19:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 60 11 38 255 7.1 0 7.3 7 10/02/2005 19:30:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 52 0 52 255 6.9 0 7.3 6.7 10/02/2005 19:40:00 1.5 0.3 1.9 0.7 1.1 0.3 1.9 0.4 0.5 0.2 1.5 0.4 58 4 58 255 6.7 0 7 6.7 10/02/2005 19:50:00 1.4 0.3 2.3 0.4 1.1 0.3 1.9 0.4 0.4 0.1 1.1 0.4 69 3 70 255 6.7 0 7 6.7 10/02/2005 20:00:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 61 8 71 255 6.7 0 7 6.7 10/02/2005 20:10:00 1.3 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 65 9 63 255 6.7 0 6.7 6.7 10/02/2005 20:20:00 1.8 0.3 2.6 0.7 1.5 0.4 2.6 0.4 0.6 0.3 1.5 0.4 79 7 83 255 6.7 0 6.7 6.7 10/02/2005 20:30:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 0.4 0.1 0.7 0.4 80 3 82 255 6.7 0 6.7 6.7 10/02/2005 20:40:00 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 74 4 81 255 6.7 0 6.7 6.7 10/02/2005 20:50:00 1.6 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.5 0.3 1.5 0.4 72 9 72 255 6.7 0 6.7 6.7 10/02/2005 21:00:00 1.4 0.3 2.3 0.4 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 53 12 66 255 6.7 0 7 6.7 10/02/2005 21:10:00 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.4 0.1 0.7 0.4 54 9 49 255 6.7 0 7 6.7 10/02/2005 21:20:00 1.8 0.5 2.6 0.7 1.5 0.6 2.6 0.4 0.8 0.5 1.9 0.4 74 13 73 255 6.8 0 7 6.7 10/02/2005 21:30:00 1.8 0.4 2.6 1.1 1.4 0.5 2.6 0.4 0.6 0.4 1.9 0.4 67 10 77 255 6.7 0 7 6.7 10/02/2005 21:40:00 1.4 0.4 2.3 0.4 0.9 0.4 2.3 0.4 0.4 0.2 1.5 0.4 60 16 76 255 6.7 0 7 6.7 10/02/2005 21:50:00 1.6 0.4 2.6 0.7 1.2 0.5 2.3 0.4 0.5 0.2 1.5 0.4 64 13 53 255 6.7 0 7 6.7 10/02/2005 22:00:00 1.9 0.5 3 0.4 1.5 0.5 2.6 0.4 0.6 0.4 1.9 0.4 71 8 85 255 6.6 0 6.7 6.5 10/02/2005 22:10:00 1.9 0.5 3 0.7 1.6 0.5 2.6 0.4 0.7 0.5 2.3 0.4 70 10 40 255 6.4 0 6.5 6.2 10/02/2005 22:20:00 1.5 0.3 2.3 0.7 1.1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 67 7 56 255 6.1 0 6.2 6 10/02/2005 22:30:00 1.7 0.4 2.6 0.7 1.3 0.5 2.6 0.4 0.5 0.3 1.5 0.4 62 10 81 255 5.8 0.1 6 5.7 10/02/2005 22:40:00 1.4 0.5 3 0.4 0.9 0.6 2.6 0.4 0.5 0.3 1.9 0.4 55 9 46 255 5.5 0 5.7 5.2 10/02/2005 22:50:00 2 0.5 3 0.7 1.7 0.5 3 0.4 0.9 0.6 2.6 0.4 48 12 46 255 5.1 0 5.5 5 10/02/2005 23:00:00 2.2 0.4 3.4 1.1 1.9 0.5 3.4 0.7 0.8 0.5 2.6 0.4 70 10 58 255 4.9 0.2 5 4.5 10/02/2005 23:10:00 2.6 0.4 3.8 1.5 2.3 0.5 3.8 1.1 1.4 0.5 3 0.4 67 9 56 255 4.4 0 4.5 4.3 10/02/2005 23:20:00 2.4 0.4 3.4 1.9 2.1 0.4 3 1.1 1 0.5 2.3 0.4 66 7 65 255 4 0.1 4.3 3.8 10/02/2005 23:30:00 2.6 0.4 3.4 1.5 2.4 0.5 3.4 1.1 1.4 0.5 2.6 0.4 62 9 63 255 3.6 0 3.8 3.5 10/02/2005 23:40:00 2.8 0.4 3.8 1.5 2.6 0.5 3.8 1.5 1.6 0.5 3 0.4 63 7 64 255 3.3 0.1 3.5 2.8 10/02/2005 23:50:00 1.7 0.4 2.6 1.1 1.2 0.4 2.6 0.4 0.4 0.1 1.1 0.4 64 6 49 255 2.8 0 3 2.6 10/03/2005 00:00:00 1.5 0.3 2.3 0.7 1 0.4 1.9 0.4 0.4 0.1 0.7 0.4 59 4 62 255 3 0 3.5 2.8 10/03/2005 00:10:00 2.1 0.5 3.4 1.1 1.7 0.5 3 0.7 0.7 0.5 2.3 0.4 66 9 55 255 2.9 0 3 2.8 10/03/2005 00:20:00 2.5 0.3 3.4 1.5 2.2 0.4 3 1.1 1.2 0.4 2.3 0.4 63 9 57 255 2.8 0 2.8 2.6 10/03/2005 00:30:00 2.5 0.3 3.4 1.9 2.2 0.4 3 1.1 1.1 0.5 2.6 0.4 71 9 70 255 2.7 0 2.8 2.6 10/03/2005 00:40:00 2.2 0.3 3 1.5 1.9 0.3 2.6 1.1 0.8 0.3 1.5 0.4 78 8 93 255 2.6 0 2.8 2.6 10/03/2005 00:50:00 2.6 0.3 3.4 1.9 2.3 0.4 3 1.5 1.2 0.5 2.6 0.4 95 8 84 255 2.4 0 2.6 2.3 10/03/2005 01:00:00 3 0.3 3.8 1.9 2.8 0.3 3.4 1.9 1.7 0.4 2.6 0.7 85 11 101 255 2 0.1 2.6 1.8 10/03/2005 01:10:00 2.5 0.4 3.4 1.1 2.3 0.5 3.4 0.7 1.4 0.5 2.6 0.4 69 9 74 255 2 0.1 2.6 1.8 10/03/2005 01:20:00 2.6 0.3 3.4 1.9 2.4 0.3 3 1.5 1.1 0.4 2.3 0.4 83 6 85 255 2.1 0 2.6 1.8 10/03/2005 01:30:00 1.9 0.3 2.6 1.5 1.6 0.3 2.6 1.1 0.4 0.1 1.1 0.4 87 3 86 255 1.8 0 2.3 1.8 10/03/2005 01:40:00 1.5 0.4 2.3 0.4 1 0.4 1.9 0.4 0.4 0 0.7 0.4 105 7 89 255 1.8 0 2.1 1.6 10/03/2005 01:50:00 1.7 0.3 2.6 0.7 1.2 0.4 2.3 0.4 0.4 0.1 1.1 0.4 117 10 128 255 1.6 0 1.8 1.4 10/03/2005 02:00:00 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.4 0.2 1.5 0.4 100 19 110 255 1.3 0 1.6 1.4 10/03/2005 02:10:00 1.7 0.5 3 0.4 1.3 0.5 2.6 0.4 0.8 0.5 2.3 0.4 126 12 127 255 1.2 0 1.6 1.1 10/03/2005 02:20:00 1.5 0.3 2.3 0.7 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 126 3 126 255 1.3 0 1.8 1.4 10/03/2005 02:30:00 1.9 0.3 2.6 1.1 1.6 0.4 2.3 0.7 0.5 0.3 1.5 0.4 120 6 126 255 1.2 0 1.6 1.4 10/03/2005 02:40:00 2.1 0.5 3.4 1.1 1.7 0.6 3 0.4 0.7 0.5 1.9 0.4 114 11 107 255 1.3 0 1.8 1.4 10/03/2005 02:50:00 2.3 0.3 3 1.5 1.9 0.4 3 0.7 0.7 0.4 1.9 0.4 101 6 113 255 1.2 0 1.4 0.9 10/03/2005 03:00:00 2.1 0.4 2.6 0.7 1.7 0.4 2.6 0.4 0.4 0.2 1.5 0.4 102 6 95 255 1 0 1.6 0.9 10/03/2005 03:10:00 1.6 0.2 2.3 1.1 1.1 0.3 1.9 0.4 0.4 0 0.4 0.4 107 1 108 255 0.9 0 1.6 0.9 10/03/2005 03:20:00 2 0.5 3 0.7 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 117 13 113 255 0.9 0 1.6 0.9 10/03/2005 03:30:00 2.4 0.3 3.4 1.9 2.1 0.3 3 1.1 0.9 0.5 2.3 0.4 92 13 101 255 0.9 0 1.4 0.9 10/03/2005 03:40:00 2.5 0.3 3.4 1.5 2.1 0.4 3 1.1 1 0.5 2.3 0.4 106 10 105 255 0.9 0 1.4 0.9 10/03/2005 03:50:00 2.3 0.4 3.4 1.5 2 0.4 3 1.1 0.6 0.4 1.9 0.4 100 8 117 255 0.9 0 1.4 0.9 10/03/2005 04:00:00 2 0.4 3 1.1 1.5 0.5 3 0.4 0.5 0.4 2.3 0.4 105 7 104 255 0.9 0 1.1 0.9 10/03/2005 04:10:00 2.5 0.3 3 1.9 2.2 0.3 3 1.1 0.9 0.5 2.3 0.4 102 8 93 255 0.7 0 0.9 0.7 10/03/2005 04:20:00 2.3 0.4 3.4 1.1 2 0.5 3 0.7 0.9 0.5 2.3 0.4 111 12 113 255 0.7 0 0.9 0.7 10/03/2005 04:30:00 2.6 0.5 3.4 1.1 2.2 0.5 3.4 0.7 0.9 0.5 2.3 0.4 111 10 111 255 0.7 0 0.9 0.7 10/03/2005 04:40:00 2.1 0.5 3 1.1 1.7 0.5 2.6 0.4 0.4 0.2 1.5 0.4 97 8 100 255 0.8 0 0.9 0.7 10/03/2005 04:50:00 2.2 0.3 2.6 1.5 1.9 0.3 2.6 1.1 0.5 0.3 1.5 0.4 96 8 105 255 0.8 0 0.9 0.7 10/03/2005 05:00:00 2 0.5 3 1.1 1.7 0.6 2.6 0.4 0.5 0.3 1.5 0.4 91 13 80 255 0.7 0 0.9 0.7 10/03/2005 05:10:00 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 135 18 145 255 0.7 0 0.7 0.7 10/03/2005 05:20:00 1.3 0.3 1.9 0.7 0.8 0.4 1.9 0.4 1 0.5 2.3 0.4 118 17 120 255 0.5 0 0.7 0.4 10/03/2005 05:30:00 1.3 0.3 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 95 8 88 255 0.4 0 0.7 0.2 10/03/2005 05:40:00 0.8 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 77 29 39 255 0.4 0 0.4 0.2 10/03/2005 05:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 39 255 0.3 0 0.4 0.2 10/03/2005 06:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 3 58 255 0.5 0 0.9 0.2 10/03/2005 06:10:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 0 58 255 0.6 0 0.9 0.4 10/03/2005 06:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 24 58 255 0.7 0 1.1 0.7 10/03/2005 06:30:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 141 19 143 255 0.7 0 0.9 0.7 10/03/2005 06:40:00 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 151 3 153 255 0.8 0.1 1.4 0.7 10/03/2005 06:50:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 142 0 142 255 0.9 0.2 1.4 0.9 10/03/2005 07:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 143 0 143 255 1 0 1.6 0.9 10/03/2005 07:10:00 1.7 0.5 3 0.7 1.3 0.6 2.6 0.4 0.5 0.4 2.3 0.4 152 5 142 255 1.1 0 1.6 0.9 10/03/2005 07:20:00 2.1 0.4 2.6 1.1 1.8 0.4 2.6 0.7 0.5 0.3 1.5 0.4 151 4 142 255 1.2 0 1.6 1.1 10/03/2005 07:30:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 141 7 144 255 1.2 0 1.6 1.4 10/03/2005 07:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 128 0 128 255 1.4 0.1 1.8 1.4 10/03/2005 07:50:00 1.2 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.4 0 0.7 0.4 117 12 108 255 1.5 0 1.8 1.6 10/03/2005 08:00:00 1.4 0.2 1.9 0.7 1.1 0.3 1.9 0.4 0.4 0.1 1.1 0.4 94 9 106 255 1.8 0.1 2.6 1.6 10/03/2005 08:10:00 1.5 0.2 1.9 1.1 1.1 0.2 1.9 0.4 0.4 0.1 1.1 0.4 88 7 86 255 2.4 0 2.8 2.3 10/03/2005 08:20:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.7 0.4 99 17 106 255 2.8 0.3 3.5 2.6 10/03/2005 08:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 84 8 81 255 3.9 0.3 4.3 3.3 10/03/2005 08:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 2 92 255 4.7 0.2 5 4.3 10/03/2005 08:50:00 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 90 10 89 255 5.4 0.1 5.7 5 10/03/2005 09:00:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 74 20 52 255 5.7 0 6 5.7 10/03/2005 09:10:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 17 13 26 255 6.9 0.4 7.5 6 10/03/2005 09:20:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 23 8 14 255 7.4 0 7.5 7.3 10/03/2005 09:30:00 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 33 11 30 255 7.3 0 7.5 7.3 10/03/2005 09:40:00 1 0.3 1.9 0.4 0.8 0.3 1.9 0.4 0.7 0.3 1.9 0.4 7 14 348 255 7.3 0 7.5 7 10/03/2005 09:50:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 8 9 18 255 8.3 0.4 9 7.5 10/03/2005 10:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 16 13 31 255 8.9 0 9 8.8 10/03/2005 10:10:00 1.7 0.5 3 0.7 1.5 0.5 2.6 0.4 1.1 0.5 2.6 0.4 7 9 15 255 9 0.2 9.6 8.8 10/03/2005 10:20:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1 0.4 1.9 0.4 11 17 340 255 9.6 0 9.6 9.3 10/03/2005 10:30:00 1.7 0.4 2.6 0.4 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 13 20 18 255 9.8 0 10.1 9.6 10/03/2005 10:40:00 1.9 0.5 3 0.7 1.8 0.5 3 0.4 1.7 0.5 3 0.4 25 22 60 255 9.4 0 9.8 9 10/03/2005 10:50:00 2.4 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.9 0.6 3.4 0.4 352 12 356 255 9.2 0 9.3 9 10/03/2005 11:00:00 1.6 0.4 3 0.7 1.4 0.5 2.6 0.4 1.2 0.4 2.3 0.4 344 16 359 255 9.5 0.2 9.8 9 10/03/2005 11:10:00 1.6 0.4 3 0.4 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 356 17 349 255 10 0 10.3 9.8 10/03/2005 11:20:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 3 18 23 255 10.5 0 10.9 10.3 10/03/2005 11:30:00 1.9 0.4 3.4 0.7 1.7 0.5 3 0.4 1.4 0.5 2.6 0.4 0 13 351 255 10.9 0 11.1 10.6 10/03/2005 11:40:00 1.9 0.6 3.8 0.4 1.6 0.7 3 0.4 1.4 0.7 3 0.4 345 18 1 255 10.7 0 10.9 10.6 10/03/2005 11:50:00 1.9 0.5 3 0.4 1.5 0.5 2.3 0.4 1.3 0.5 2.6 0.4 358 19 333 255 10.5 0 10.9 10.3 10/03/2005 12:00:00 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 329 22 328 255 10.3 0 10.6 10.1 10/03/2005 12:10:00 1.7 0.4 2.6 0.4 1.2 0.5 2.6 0.4 1.3 0.5 2.6 0.4 347 17 352 255 10.9 0.3 11.4 10.6 10/03/2005 12:20:00 1.9 0.4 3 0.7 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 12 11 255 11.7 0.2 11.9 11.4 10/03/2005 12:30:00 1.8 0.4 3 0.7 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 341 15 334 255 11.7 0 11.9 11.4 10/03/2005 12:40:00 2 0.6 3.4 0.7 1.5 0.6 3 0.4 1.4 0.6 3.4 0.4 333 17 335 255 11.2 0 11.7 11.1 10/03/2005 12:50:00 2.1 0.4 3.4 1.1 1.9 0.5 3 0.7 1.8 0.5 2.6 0.4 5 12 341 255 11.1 0 11.4 11.1 10/03/2005 13:00:00 2.3 0.4 3 1.1 2.2 0.4 3 1.1 1.9 0.5 2.6 0.4 7 7 15 255 11.1 0 11.1 11.1 10/03/2005 13:10:00 2 0.6 3 0.7 1.9 0.6 3 0.4 1.6 0.7 3 0.4 358 8 358 255 11 0.1 11.4 10.9 10/03/2005 13:20:00 1.8 0.4 3.4 0.7 1.6 0.5 3.4 0.4 1.2 0.5 2.6 0.4 356 15 337 255 11.7 0.2 12.2 11.4 10/03/2005 13:30:00 1.6 0.4 3 0.7 1.5 0.4 3 0.7 1.3 0.5 2.6 0.4 2 19 337 255 12.6 0 12.7 12.2 10/03/2005 13:40:00 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1 0.4 2.3 0.4 7 22 1 255 12.7 0.2 13.5 12.5 10/03/2005 13:50:00 2.8 0.8 4.9 1.5 2.6 0.8 4.6 0.7 2.1 0.8 3.8 0.4 351 15 2 255 13.7 0.2 14.6 13.3 10/03/2005 14:00:00 3.3 0.5 4.9 2.3 3.3 0.6 4.9 1.9 2.8 0.7 4.2 1.1 4 13 3 255 14.1 0.1 14.6 13.8 10/03/2005 14:10:00 3.1 0.6 4.9 1.5 3.1 0.6 4.6 1.1 2.7 0.6 4.2 1.1 24 12 26 255 13.4 0.4 14.4 12.7 10/03/2005 14:20:00 3.5 0.6 4.9 1.9 3.5 0.6 4.9 1.9 3.2 0.6 4.9 0.7 46 12 40 255 12.6 0 12.7 12.5 10/03/2005 14:30:00 3.5 0.5 4.6 1.5 3.5 0.5 4.6 1.9 3.1 0.6 4.9 1.5 32 9 41 255 12.2 0.2 12.7 11.7 10/03/2005 14:40:00 2.9 0.8 4.6 0.7 2.9 0.8 4.6 1.1 2.5 0.8 4.2 0.7 32 13 52 255 12 0.1 12.7 11.7 10/03/2005 14:50:00 3.1 0.6 4.6 1.1 3.2 0.6 4.6 1.1 2.7 0.7 4.2 1.1 25 10 22 255 12.9 0.3 13.5 12.2 10/03/2005 15:00:00 2.7 0.8 5.3 0.7 2.7 0.8 4.9 1.1 2.4 0.8 5.3 0.4 66 22 70 255 13.1 0 13.5 13 10/03/2005 15:10:00 3.3 0.7 5.3 1.1 3.2 0.7 4.9 1.1 3 0.6 4.6 1.5 37 15 34 255 12.7 0 13.3 12.5 10/03/2005 15:20:00 2 0.8 4.2 0.4 2 0.8 4.2 0.4 1.6 0.9 4.6 0.4 44 18 43 255 12.5 0 12.7 12.2 10/03/2005 15:30:00 2 0.9 4.2 0.4 1.9 0.9 3.8 0.4 1.6 0.8 4.2 0.4 40 35 55 255 12.6 0 12.7 12.5 10/03/2005 15:40:00 3.1 0.7 4.6 1.1 3 0.8 4.6 1.1 2.6 0.8 4.2 0.4 73 21 83 255 12.1 0.2 12.5 11.7 10/03/2005 15:50:00 2.5 0.7 4.6 0.4 2.5 0.7 4.6 0.4 1.9 0.8 3.8 0.4 83 14 85 255 11.3 0.1 11.9 11.1 10/03/2005 16:00:00 2.2 0.6 3.4 0.7 2.2 0.6 3.4 0.7 1.7 0.7 3 0.4 65 15 86 255 11.3 0 11.7 11.1 10/03/2005 16:10:00 2.6 0.4 3.8 1.1 2.6 0.5 3.4 1.1 2.1 0.5 3 0.7 21 18 16 255 11 0.1 11.4 10.6 10/03/2005 16:20:00 2.5 0.6 4.2 1.5 2.5 0.6 4.2 1.1 2.1 0.7 4.2 0.7 25 16 37 255 10.6 0 10.9 10.6 10/03/2005 16:30:00 2.6 0.6 3.8 0.7 2.6 0.6 3.8 0.7 2.3 0.7 3.8 0.4 39 11 59 255 10.9 0 11.1 10.6 10/03/2005 16:40:00 3 0.7 4.9 1.1 2.9 0.7 4.9 1.5 2.3 0.8 4.2 0.4 34 14 35 255 11 0 11.1 10.9 10/03/2005 16:50:00 3.7 0.8 6.1 2.3 3.7 0.8 6.5 1.9 3.1 0.9 5.7 1.1 25 10 24 255 11 0 11.1 10.9 10/03/2005 17:00:00 3.4 0.5 4.9 2.3 3.4 0.5 4.9 2.3 2.9 0.7 5.3 1.5 31 12 21 255 10.9 0 11.1 10.9 10/03/2005 17:10:00 3.6 0.8 5.7 1.9 3.6 0.8 5.7 1.9 3.1 0.9 5.3 1.1 30 13 2 255 10.9 0 11.1 10.9 10/03/2005 17:20:00 2.7 0.7 4.9 1.1 2.7 0.7 5.3 1.1 2.2 0.8 4.9 0.7 51 14 39 255 10.7 0 10.9 10.6 10/03/2005 17:30:00 2.4 0.4 3.4 1.5 2.3 0.5 3.4 1.1 1.8 0.6 3 0.4 63 15 71 255 10.3 0.1 10.6 10.1 10/03/2005 17:40:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 1.5 0.5 2.6 0.4 65 14 39 255 10 0 10.3 9.6 10/03/2005 17:50:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.7 0.5 2.6 0.4 71 10 60 255 9.4 0.1 9.8 9 10/03/2005 18:00:00 3 0.4 3.8 2.3 3 0.4 4.2 2.3 2.2 0.4 3.4 1.1 76 9 87 255 8.6 0.2 9 8.3 10/03/2005 18:10:00 3 0.4 4.2 1.5 3 0.5 4.2 1.5 2.2 0.4 3.4 0.7 77 7 84 255 7.8 0.2 8.3 7.3 10/03/2005 18:20:00 2.9 0.3 3.8 1.9 2.9 0.3 4.2 2.3 2 0.3 3 1.1 85 7 96 255 6.9 0.2 7.3 6.5 10/03/2005 18:30:00 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.3 2.5 0.5 3.8 1.5 92 9 88 255 6.1 0.1 6.5 5.7 10/03/2005 18:40:00 3.4 0.6 5.7 1.9 3.4 0.6 5.7 1.9 2.5 0.7 4.2 0.7 92 10 101 255 6.1 0.1 6.5 5.7 10/03/2005 18:50:00 3.9 0.7 5.7 1.9 3.9 0.7 5.7 1.9 2.9 0.7 4.9 1.1 108 12 97 255 6.2 0 6.5 6 10/03/2005 19:00:00 3.7 0.7 5.3 1.5 3.7 0.7 5.3 1.9 2.7 0.8 4.2 0.7 106 11 105 255 6.5 0.1 6.7 6.2 10/03/2005 19:10:00 3.9 0.8 5.7 1.5 3.9 0.8 5.7 1.5 2.9 0.7 4.9 1.1 102 13 120 255 7.1 0.4 7.8 6.5 10/03/2005 19:20:00 4.3 0.8 6.5 2.3 4.2 0.7 6.1 2.3 3.2 0.8 5.3 1.1 103 15 115 255 7.8 0 8 7.5 10/03/2005 19:30:00 4.3 1 6.8 2.3 4.3 1 6.5 2.3 3.3 1.1 6.5 1.1 98 13 90 255 8.1 0 8.3 8 10/03/2005 19:40:00 4.7 1 6.8 2.3 4.6 1 6.5 1.5 3.7 1.1 6.8 0.4 106 15 94 255 8.1 0 8.3 8 10/03/2005 19:50:00 4.7 1 6.8 2.3 4.6 1 6.8 1.9 3.8 1 6.1 1.5 104 13 115 255 8.3 0 8.5 8.3 10/03/2005 20:00:00 4.8 1 7.2 2.3 4.7 1 6.8 2.3 3.9 1 6.5 1.5 101 12 95 255 8.2 0 8.5 8.3 10/03/2005 20:10:00 5.3 1 8 3 5.2 1 8.4 2.3 4.2 1 6.5 1.5 104 13 104 255 8.3 0 8.5 8.3 10/03/2005 20:20:00 5.6 1 8 2.6 5.5 1 7.6 2.6 4.4 1.1 6.8 1.9 103 12 96 255 8.2 0 8.5 8.3 10/03/2005 20:30:00 5.7 1.2 9.1 2.6 5.7 1.1 8.8 2.6 4.6 1.2 7.6 1.9 105 14 131 255 8.2 0 8.5 8 10/03/2005 20:40:00 5.6 1.2 8.4 2.3 5.5 1.2 8 2.3 4.4 1.1 7.2 1.9 107 14 110 255 8.1 0 8.3 8 10/03/2005 20:50:00 5.2 1 7.6 2.6 5 1 7.2 2.6 4.1 0.9 6.8 2.3 102 13 90 255 7.8 0 8 7.8 10/03/2005 21:00:00 5.3 1.1 8.4 3 5.2 1.1 8 2.6 4.3 1.1 6.8 2.3 104 12 112 255 7.6 0 7.8 7.5 10/03/2005 21:10:00 5.5 1.2 8.4 2.6 5.4 1.1 8.8 2.6 4.4 1.2 7.2 1.1 103 13 108 255 7.5 0 7.8 7.3 10/03/2005 21:20:00 5.4 1.2 8 1.5 5.3 1.1 7.6 1.9 4.1 1.2 7.2 1.1 99 13 104 255 7.3 0 7.5 7.3 10/03/2005 21:30:00 5.3 1 8 2.6 5.2 1 7.6 2.3 3.9 0.9 6.8 2.3 104 12 94 255 7.1 0 7.3 7 10/03/2005 21:40:00 5.7 1 8.4 2.3 5.6 1 8 2.6 4.5 1.1 7.6 1.9 106 13 98 255 7.2 0 7.3 7 10/03/2005 21:50:00 5.2 1 6.8 2.3 5 1 7.2 1.9 4 1 6.5 1.5 107 11 99 255 7.3 0 7.3 7.3 10/03/2005 22:00:00 5.3 1 8.4 3.4 5.2 1 8 3 4 1 7.6 1.9 110 13 111 255 7 0.1 7.3 7 10/03/2005 22:10:00 5.5 1.1 8.8 3 5.4 1.1 8.4 2.3 4.3 1.1 7.2 1.9 110 15 115 255 7 0 7 7 10/03/2005 22:20:00 5.1 1.1 8.4 2.6 5.1 1 8.4 2.6 4.2 1.2 7.2 1.1 100 13 106 255 6.8 0 7 6.7 10/03/2005 22:30:00 5.7 1.2 9.1 3.4 5.6 1.1 8.8 3 4.6 1.2 8.8 2.3 105 15 122 255 6.7 0 7 6.7 10/03/2005 22:40:00 6.1 1.1 8.8 2.6 6 1 8.4 2.6 5 1 7.6 2.3 107 13 101 255 6.7 0 7 6.7 10/03/2005 22:50:00 5.8 1.3 8.8 1.9 5.7 1.2 8.4 2.3 4.7 1.2 8 1.9 105 15 119 255 6.8 0 7 6.7 10/03/2005 23:00:00 6.1 1.2 9.1 2.3 5.9 1.2 8.8 2.6 5.1 1.1 8.4 2.3 103 15 101 255 6.7 0 7 6.7 10/03/2005 23:10:00 6.3 1.3 9.5 3 6.3 1.2 8.8 3 5.2 1.3 9.5 2.3 99 15 87 255 6.7 0 7 6.7 10/03/2005 23:20:00 6.7 1.5 10.3 2.6 6.6 1.4 10.3 3.4 5.4 1.5 9.5 2.3 97 13 115 255 6.7 0 6.7 6.7 10/03/2005 23:30:00 6.4 1.3 9.9 3.4 6.3 1.3 9.5 3 5.2 1.4 8.8 1.5 97 16 89 255 6.7 0 6.7 6.7 10/03/2005 23:40:00 6.5 1.3 9.9 3 6.3 1.3 9.5 2.6 5.3 1.4 8.8 1.9 101 13 93 255 6.7 0 7 6.7 10/03/2005 23:50:00 6.2 1.2 9.5 3 6.1 1.1 9.1 3 5.1 1.1 8.4 2.3 104 15 106 255 6.7 0 7 6.7 10/04/2005 00:00:00 5.8 1.1 8.8 3 5.7 1.1 8.8 3 4.9 1.2 8.8 2.3 105 13 101 255 6.7 0 6.7 6.5 10/04/2005 00:10:00 6.2 1 8.8 3 6 1 8.4 2.6 4.9 1 8.8 2.3 107 15 106 255 6.6 0 6.7 6.5 10/04/2005 00:20:00 6.7 1.2 9.5 3.4 6.6 1.1 9.9 3.8 5.5 1.2 8.4 2.6 106 13 109 255 6.6 0 6.7 6.5 10/04/2005 00:30:00 6.3 1.3 9.5 3.4 6.1 1.3 9.1 3 5.1 1.3 8.8 1.9 105 15 91 255 6.7 0 6.7 6.7 10/04/2005 00:40:00 6.2 1.5 11.1 3 6.1 1.5 11.5 3 5 1.5 9.1 1.5 101 17 90 255 6.6 0 6.7 6.5 10/04/2005 00:50:00 6.9 1.3 10.3 3.8 6.8 1.3 9.9 3.8 5.7 1.3 9.5 3 103 15 110 255 6.7 0 6.7 6.7 10/04/2005 01:00:00 6.7 1.4 10.3 3.4 6.6 1.4 10.3 3.4 5.4 1.3 9.1 2.3 101 16 104 255 6.7 0 6.7 6.5 10/04/2005 01:10:00 7.4 1.5 11.8 3 7.3 1.5 11.1 3 6 1.6 10.3 2.3 99 15 100 255 6.6 0 6.7 6.5 10/04/2005 01:20:00 7.1 1.7 12.2 3.4 6.9 1.7 11.8 3.4 6 1.9 11.5 2.3 98 15 97 255 6.4 0 6.7 6.2 10/04/2005 01:30:00 6.6 1.5 11.1 3 6.5 1.5 10.7 3 5.5 1.5 9.9 1.9 94 17 93 255 6.3 0.1 6.5 6.2 10/04/2005 01:40:00 6.1 1.3 9.1 2.3 6 1.4 9.9 2.3 5.2 1.4 8.8 1.5 89 18 88 255 6.2 0 6.2 6.2 10/04/2005 01:50:00 6.6 1.7 10.3 1.9 6.5 1.7 10.7 2.3 5.7 1.5 10.7 2.3 96 17 74 255 6.2 0 6.5 6.2 10/04/2005 02:00:00 6.4 1.4 10.3 2.6 6.4 1.4 10.3 2.6 5.4 1.5 9.1 2.3 98 18 115 255 6.2 0 6.2 6.2 10/04/2005 02:10:00 6.4 1.5 11.1 3 6.3 1.5 11.1 3 5.2 1.5 9.1 0.7 98 15 90 255 6.1 0 6.2 6 10/04/2005 02:20:00 6.7 1.3 10.3 3.8 6.6 1.3 10.3 3.8 5.6 1.4 8.8 1.9 96 14 106 255 6 0 6 5.7 10/04/2005 02:30:00 6.9 1.5 10.7 3 6.7 1.5 10.7 2.6 5.9 1.5 9.5 2.3 98 14 96 255 5.9 0 6 5.7 10/04/2005 02:40:00 6.7 1.3 10.7 3.8 6.5 1.3 10.3 3.8 5.5 1.2 9.1 3 106 17 115 255 5.8 0 6 5.7 10/04/2005 02:50:00 6.7 1.5 12.6 4.2 6.6 1.5 11.8 3.4 5.6 1.6 11.5 1.9 106 15 104 255 5.7 0 6 5.7 10/04/2005 03:00:00 6 1.5 10.3 2.6 5.8 1.3 10.3 2.3 4.8 1.5 9.5 1.9 95 18 99 255 5.7 0 5.7 5.7 10/04/2005 03:10:00 6.8 1.7 11.5 2.6 6.7 1.7 11.1 2.3 5.7 1.8 10.3 1.1 98 16 91 255 5.7 0 5.7 5.7 10/04/2005 03:20:00 6.8 1.6 11.5 3.4 6.6 1.6 11.1 3 5.7 1.7 10.3 1.1 99 18 95 255 5.7 0 5.7 5.7 10/04/2005 03:30:00 7.4 1.5 11.1 3.4 7.3 1.5 10.7 3.4 6 1.5 9.5 3 103 16 125 255 5.8 0 6 5.7 10/04/2005 03:40:00 7.1 1.7 11.5 3.4 7 1.7 11.5 3 5.7 1.5 9.5 2.3 102 15 118 255 5.9 0 6 5.7 10/04/2005 03:50:00 7.1 1.6 11.8 3.8 7 1.6 11.8 3.8 5.7 1.6 11.8 2.3 102 15 91 255 5.8 0 6 5.7 10/04/2005 04:00:00 7.2 1.7 11.8 2.6 6.9 1.7 12.2 2.3 6 1.7 10.3 1.1 102 16 105 255 5.7 0 5.7 5.7 10/04/2005 04:10:00 6.5 1.5 10.7 3.4 6.4 1.5 10.7 3 5.6 1.4 10.3 2.6 102 15 115 255 5.6 0 5.7 5.5 10/04/2005 04:20:00 7 1.4 11.1 3 6.9 1.5 10.7 3 5.7 1.5 9.9 2.3 107 14 106 255 5.6 0 5.7 5.5 10/04/2005 04:30:00 7 1.4 10.7 3 6.9 1.4 10.7 3.4 5.7 1.4 9.5 2.6 107 16 127 255 5.5 0 5.7 5.5 10/04/2005 04:40:00 7.2 1.6 10.7 2.6 7.1 1.7 10.7 2.6 6.1 1.7 10.7 2.3 103 15 101 255 5.6 0 5.7 5.5 10/04/2005 04:50:00 6.8 1.5 10.7 3 6.6 1.5 10.3 3 5.5 1.5 8.8 2.3 101 15 108 255 5.6 0 5.7 5.5 10/04/2005 05:00:00 6.8 1.4 10.7 3.4 6.6 1.3 10.7 3.4 5.4 1.4 9.1 1.9 105 15 88 255 5.6 0 5.7 5.5 10/04/2005 05:10:00 6.5 1.3 9.9 3.4 6.4 1.3 10.3 2.6 5.2 1.2 8.8 2.6 104 16 102 255 5.5 0 5.7 5.5 10/04/2005 05:20:00 6.6 1.4 9.9 2.6 6.5 1.3 9.9 3.4 5.3 1.5 8.8 2.3 100 15 108 255 5.5 0 5.7 5.2 10/04/2005 05:30:00 6.8 1.5 9.5 3.4 6.6 1.5 9.5 2.6 5.6 1.4 8.8 2.6 98 14 105 255 5.6 0 5.7 5.5 10/04/2005 05:40:00 6.4 1.4 10.3 3 6.3 1.4 10.7 2.3 5.2 1.4 8.8 2.6 100 16 94 255 5.4 0 5.7 5.5 10/04/2005 05:50:00 7 1.5 11.5 2.6 6.8 1.5 11.1 2.6 5.8 1.6 11.1 1.1 100 15 90 255 5.4 0 5.5 5.5 10/04/2005 06:00:00 7 1.5 10.3 3 6.8 1.5 10.3 3 5.8 1.4 9.5 2.3 106 16 115 255 5.4 0 5.7 5.5 10/04/2005 06:10:00 7.6 1.3 11.5 4.6 7.4 1.3 10.7 3.8 6.3 1.4 9.9 2.3 103 14 86 255 5.6 0 5.7 5.5 10/04/2005 06:20:00 6.6 1.3 10.7 3.4 6.4 1.3 9.9 2.6 5.3 1.3 8.8 2.3 106 15 94 255 5.4 0 5.7 5.2 10/04/2005 06:30:00 7.2 1.4 10.3 3 7.1 1.4 9.9 3 6 1.3 10.3 2.6 105 17 126 255 5.2 0 5.5 5 10/04/2005 06:40:00 6.4 1.6 11.5 2.3 6.4 1.6 11.1 2.6 5.2 1.7 11.1 1.9 105 17 91 255 5.2 0 5.5 5 10/04/2005 06:50:00 7.3 1.5 11.1 3 7.1 1.5 11.1 2.6 5.9 1.7 10.3 2.3 105 17 86 255 5.1 0 5.2 5 10/04/2005 07:00:00 7.3 1.2 10.7 4.2 7.2 1.2 10.3 4.2 6.3 1.3 10.7 3 102 14 106 255 5.2 0 5.5 5 10/04/2005 07:10:00 7.5 1.6 11.8 3.4 7.3 1.5 11.1 3.8 6.3 1.5 10.3 1.9 104 16 93 255 5.1 0 5.2 5 10/04/2005 07:20:00 6.9 1.5 11.1 3 6.8 1.5 11.1 2.3 5.5 1.6 9.9 1.5 101 17 106 255 5.1 0 5 5 10/04/2005 07:30:00 7.2 1.5 11.1 3 7.1 1.4 10.7 3.4 5.8 1.5 9.5 2.3 100 15 100 255 5.1 0 5 5 10/04/2005 07:40:00 7.6 1.7 13.3 3.8 7.5 1.7 12.6 3.4 6.2 1.7 11.5 1.9 101 15 148 255 5.2 0 5.5 5 10/04/2005 07:50:00 7.4 1.4 11.5 3.8 7.2 1.4 11.8 3 6.1 1.5 9.5 2.6 102 14 123 255 5.2 0 5.5 5.2 10/04/2005 08:00:00 6.5 1.4 10.3 2.6 6.3 1.4 10.3 2.3 5.1 1.5 9.1 1.5 101 17 104 255 5.5 0.2 6 5.2 10/04/2005 08:10:00 7.1 1.6 11.5 3 6.9 1.6 11.5 3.4 5.9 1.6 11.1 2.3 101 16 92 255 5.9 0 6 5.7 10/04/2005 08:20:00 8.1 1.7 12.6 3.8 7.9 1.7 11.8 3.4 6.8 1.7 11.1 3 103 15 105 255 6.1 0 6.2 5.7 10/04/2005 08:30:00 7.9 1.7 11.8 3.8 7.6 1.7 11.5 3.4 6.8 1.7 10.3 1.9 100 16 105 255 6.2 0 6.2 6 10/04/2005 08:40:00 7.4 1.7 12.6 2.3 7.2 1.7 13 2.6 6.2 1.6 10.7 1.1 101 15 84 255 6.1 0 6.2 6 10/04/2005 08:50:00 7.5 1.7 12.6 3.8 7.2 1.8 12.6 3 6.2 1.8 12.2 1.9 101 17 92 255 6.3 0.1 6.5 6 10/04/2005 09:00:00 7.3 1.7 11.8 3.4 7 1.7 11.8 2.6 6.1 1.7 11.5 2.3 98 16 93 255 6.4 0 6.7 6.2 10/04/2005 09:10:00 7.3 1.7 11.5 2.6 7.1 1.7 11.8 2.3 6.4 1.5 10.7 2.6 97 17 99 255 6.8 0.1 7 6.5 10/04/2005 09:20:00 7.2 1.6 13 3.4 7 1.6 12.2 3 6.4 1.6 11.8 3 96 15 103 255 6.8 0 7 6.7 10/04/2005 09:30:00 7.1 2.1 13 2.3 6.9 2.1 12.6 2.3 5.9 2 11.1 1.5 88 18 95 255 7.1 0 7.3 7 10/04/2005 09:40:00 7.5 1.8 12.6 3.4 7.3 1.9 12.2 2.6 6 1.7 9.9 1.1 95 18 95 255 7.3 0 7.5 7.3 10/04/2005 09:50:00 7.6 2.2 13.3 3 7.6 2.2 13.3 3 6.4 2.1 12.6 2.6 100 17 116 255 7.8 0.1 8.3 7.5 10/04/2005 10:00:00 7.7 1.8 12.2 3 7.6 1.7 11.8 3.4 6.5 1.7 11.1 1.9 99 18 93 255 8 0 8.3 7.8 10/04/2005 10:10:00 8.1 1.7 13 3 8 1.7 12.6 3.8 7.1 1.7 11.8 3 102 17 109 255 8.2 0 8.5 8 10/04/2005 10:20:00 6.4 2.1 11.8 2.3 6.4 2.1 11.5 0.7 5.5 1.9 11.1 1.5 96 20 104 255 8.7 0.1 9 8.5 10/04/2005 10:30:00 7.1 2.3 12.2 2.3 7.1 2.2 12.6 3 6 2.1 11.1 1.5 96 19 127 255 8.9 0 9 8.8 10/04/2005 10:40:00 7.5 2 13 3 7.4 1.9 13 3 6.4 1.9 11.8 1.5 99 17 112 255 8.9 0 9 8.8 10/04/2005 10:50:00 6.8 1.8 11.5 1.9 6.8 1.7 11.5 1.9 5.8 1.7 11.5 1.9 100 17 110 255 8.6 0.1 9 8.5 10/04/2005 11:00:00 6.1 1.6 10.3 2.6 6 1.5 9.5 3.4 5.1 1.7 10.3 1.5 98 19 87 255 8.8 0 9 8.5 10/04/2005 11:10:00 7.9 1.5 11.8 4.6 7.7 1.5 11.8 4.2 6.8 1.5 10.3 3 102 14 110 255 8.5 0.2 9 8 10/04/2005 11:20:00 8.1 1.8 13 4.2 8 1.7 11.8 3.8 7 1.7 11.1 3.4 101 17 98 255 7.9 0 8.3 7.8 10/04/2005 11:30:00 8.3 1.7 13.7 4.6 8.2 1.7 13 4.2 7.3 1.7 11.5 3 100 13 87 255 7.8 0 8 7.8 10/04/2005 11:40:00 6.9 1.7 11.8 3 6.9 1.7 12.2 2.6 5.8 1.7 10.3 2.6 99 19 78 255 7.9 0 8 7.8 10/04/2005 11:50:00 7.4 1.6 11.8 3 7.3 1.7 11.5 3 6.3 1.5 10.7 3 98 18 82 255 8 0 8.3 7.8 10/04/2005 12:00:00 7.1 1.7 11.5 3 7.2 1.7 11.5 3.4 6.1 1.8 11.1 1.1 97 18 99 255 8.2 0 8.5 8 10/04/2005 12:10:00 8.1 1.8 12.2 3.4 8.1 1.8 12.2 3.8 6.8 1.9 12.2 3 101 18 104 255 8.4 0 8.5 8.3 10/04/2005 12:20:00 7.7 1.8 11.8 3.4 7.6 1.7 12.2 3.8 6.5 1.7 11.1 1.9 98 18 94 255 8.4 0 8.5 8.5 10/04/2005 12:30:00 7.6 2.1 14.1 3 7.5 2.1 14.1 3 6.3 2.4 13.3 1.5 96 19 103 255 8.5 0 8.5 8.5 10/04/2005 12:40:00 8.4 1.9 13.7 3.8 8.4 1.9 13.3 3.4 7.2 1.9 12.6 2.6 93 17 100 255 8.4 0 8.5 8.5 10/04/2005 12:50:00 7.9 2 13.7 2.6 7.8 1.9 13 3.8 6.4 2 12.2 1.9 96 18 81 255 8.4 0 8.5 8.5 10/04/2005 13:00:00 8.9 2.3 14.5 3.8 8.8 2.3 14.1 4.2 7.6 2.2 14.1 3.4 98 15 88 255 8.4 0 8.5 8.3 10/04/2005 13:10:00 9.4 2 13.3 3.8 9.2 2.1 13 3 8.2 1.9 12.2 2.3 103 14 106 255 8.4 0 8.5 8.3 10/04/2005 13:20:00 7.4 1.8 13.7 3.4 7.3 1.7 13.3 3 6.2 1.8 12.2 2.6 101 19 101 255 8.5 0 8.8 8.5 10/04/2005 13:30:00 7.1 1.8 12.6 3 6.9 1.9 11.8 2.3 5.9 1.9 11.8 1.9 97 15 88 255 8.9 0 9 8.8 10/04/2005 13:40:00 6.5 1.7 11.5 1.9 6.3 1.7 11.1 2.3 5.5 1.7 10.3 0.7 98 17 124 255 8.9 0 9 8.8 10/04/2005 13:50:00 5.9 1.5 10.7 2.6 5.8 1.5 10.3 2.6 4.9 1.6 8.8 1.5 95 20 91 255 8.9 0 9 8.8 10/04/2005 14:00:00 6.7 1.8 11.1 2.6 6.6 1.7 10.7 2.3 5.8 1.8 10.3 2.3 97 15 99 255 9 0 9.3 9 10/04/2005 14:10:00 6.3 1.6 10.7 3 6.1 1.6 11.1 3 5.4 1.6 10.3 2.6 94 17 116 255 9.5 0.1 9.8 9 10/04/2005 14:20:00 7.3 1.7 11.8 3 7.2 1.7 11.8 3.4 6.3 1.8 11.1 2.3 95 15 99 255 9.9 0.1 10.3 9.6 10/04/2005 14:30:00 6.8 1.8 11.1 2.6 6.7 1.7 10.7 3 5.8 2 10.3 0.7 98 19 89 255 10.5 0 10.9 10.3 10/04/2005 14:40:00 6.4 1.7 10.7 1.5 6.2 1.7 10.7 1.9 5.5 1.9 11.5 1.1 85 23 81 255 10.8 0 11.1 10.6 10/04/2005 14:50:00 7 1.8 11.5 1.9 6.9 1.8 10.7 1.5 6 1.7 11.1 0.7 96 15 84 255 10.6 0.1 10.9 10.3 10/04/2005 15:00:00 6.8 1.7 11.8 3 6.5 1.7 11.8 1.5 5.8 1.6 9.5 2.3 94 20 73 255 10.2 0 10.3 10.1 10/04/2005 15:10:00 6.7 1.8 11.5 3 6.6 1.8 11.1 3 5.6 2 11.8 1.1 95 20 109 255 10.3 0.1 10.6 10.1 10/04/2005 15:20:00 7.4 1.9 11.5 2.3 7.3 1.9 11.1 1.9 6.2 1.7 10.3 2.3 99 17 118 255 10.6 0 10.6 10.6 10/04/2005 15:30:00 7.5 1.6 11.8 3.8 7.4 1.6 11.1 3 6.5 1.7 11.5 0.7 97 17 105 255 10.3 0.1 10.6 10.1 10/04/2005 15:40:00 8 1.7 11.8 3 7.9 1.6 11.8 3.8 7.1 1.7 11.1 3 95 16 80 255 9.8 0.1 10.1 9.6 10/04/2005 15:50:00 6.8 2.1 11.8 2.6 6.7 2.1 11.8 2.6 5.6 2.2 11.1 1.5 89 19 74 255 9.5 0 9.6 9.3 10/04/2005 16:00:00 7.1 2 11.8 1.9 7 2 12.6 1.9 5.8 1.9 11.5 1.1 90 19 111 255 9.4 0 9.6 9.3 10/04/2005 16:10:00 7 2 13 3.4 6.9 1.9 12.6 3 6.1 1.7 11.1 2.3 90 19 91 255 9.4 0 9.6 9.3 10/04/2005 16:20:00 7.5 2.4 14.1 2.6 7.4 2.5 14.1 1.9 6.3 2.3 14.5 2.3 88 19 94 255 9.4 0 9.6 9.3 10/04/2005 16:30:00 8.1 1.7 12.2 2.6 8.1 1.7 12.2 3 6.8 1.7 10.7 2.6 95 16 108 255 9.4 0 9.6 9.3 10/04/2005 16:40:00 7.8 1.8 12.6 2.6 7.5 1.8 13 3.4 6.5 1.7 11.8 2.6 94 15 70 255 9.2 0 9.3 9 10/04/2005 16:50:00 7.9 2 13.3 2.3 7.8 1.9 13.3 3 6.5 1.9 11.8 2.6 89 15 95 255 9.2 0 9.3 9.3 10/04/2005 17:00:00 7.1 2.2 13.3 2.6 6.9 2.2 13.3 1.5 5.9 2.1 14.1 1.9 94 20 97 255 9.2 0 9.3 9 10/04/2005 17:10:00 7.7 2.1 14.1 3 7.7 2.2 14.9 2.6 6.5 2 13 2.6 90 19 102 255 9.2 0 9.3 9 10/04/2005 17:20:00 6.7 1.8 13.7 3 6.6 1.7 13.3 3 5.7 1.9 11.8 1.9 89 20 113 255 9.1 0 9.3 9 10/04/2005 17:30:00 8.6 2 14.1 3.8 8.6 2 14.1 3 7.2 1.9 12.2 2.6 93 14 131 255 9 0 9 9 10/04/2005 17:40:00 7.5 2.3 13 2.6 7.3 2.3 13.3 2.6 6.4 2.1 11.8 1.5 93 19 99 255 8.9 0 9 8.8 10/04/2005 17:50:00 8.2 2.4 15.3 3.8 8.1 2.4 15.3 2.6 6.8 2.3 12.6 1.1 94 17 92 255 8.8 0 9 8.5 10/04/2005 18:00:00 8.8 2.5 15.6 2.3 8.8 2.5 15.3 1.9 7.5 2.4 15.3 1.9 91 18 120 255 8.3 0 8.8 8.3 10/04/2005 18:10:00 8.5 2.2 15.6 3.8 8.6 2.3 15.3 4.2 7.1 2.2 13.3 2.6 91 19 84 255 8.2 0 8.3 8.3 10/04/2005 18:20:00 9.4 2.4 15.6 3.8 9.3 2.4 16.1 4.2 8 2.3 14.1 1.1 97 16 95 255 8.1 0 8.3 8 10/04/2005 18:30:00 8.4 2.3 14.1 3.8 8.4 2.4 15.3 3.4 6.8 2.2 14.1 2.3 92 19 100 255 8 0 8 7.8 10/04/2005 18:40:00 8.6 2.4 14.9 4.2 8.5 2.5 15.3 3.4 7.4 2.6 14.1 2.3 90 18 117 255 7.8 0 8 7.8 10/04/2005 18:50:00 9.7 2.2 15.3 5.3 9.6 2.1 14.9 4.6 8.2 2.2 13.7 3.4 92 15 100 255 7.8 0 7.8 7.8 10/04/2005 19:00:00 7.9 2.1 14.5 2.6 7.8 2.1 14.5 2.6 6.2 2.2 13.7 1.1 91 20 113 255 7.8 0 7.8 7.5 10/04/2005 19:10:00 8.4 2.1 13.3 3 8.3 2.1 13 3 7.2 2 12.2 2.3 84 20 65 255 7.8 0 7.8 7.5 10/04/2005 19:20:00 8.4 2.4 16.4 3 8.2 2.3 16.1 3.4 7.3 2.2 12.2 1.9 88 18 99 255 7.8 0 7.8 7.8 10/04/2005 19:30:00 7.3 2 12.2 3 7.1 1.9 11.8 3 5.9 1.9 11.1 1.9 88 21 101 255 7.7 0 7.8 7.5 10/04/2005 19:40:00 8.3 1.9 13.3 4.2 8.1 1.9 13 3.8 7 2.1 12.6 2.6 91 16 97 255 7.6 0 7.8 7.5 10/04/2005 19:50:00 7.2 1.8 11.8 3 7.1 1.9 11.8 2.3 6.2 1.8 11.5 2.3 94 17 74 255 7.6 0 7.8 7.5 10/04/2005 20:00:00 7.3 1.9 12.2 2.6 7.2 1.8 11.8 2.6 6.2 1.8 11.5 2.3 94 16 88 255 7.5 0 7.8 7.5 10/04/2005 20:10:00 7.1 1.8 11.5 3 6.9 1.8 11.8 2.3 5.9 1.7 10.7 2.3 93 15 79 255 7.4 0 7.5 7.3 10/04/2005 20:20:00 7.4 1.6 11.5 3.4 7.4 1.5 11.1 3.8 6.2 1.7 10.3 1.9 94 18 102 255 7.3 0 7.5 7.3 10/04/2005 20:30:00 6.8 1.8 11.1 2.6 6.6 1.9 10.7 2.3 5.5 2 10.7 0.7 93 18 109 255 7.4 0 7.5 7.3 10/04/2005 20:40:00 6.6 1.5 9.9 3.8 6.4 1.4 9.5 3.4 5.6 1.5 9.9 2.3 97 17 85 255 7.3 0 7.3 7.3 10/04/2005 20:50:00 5.7 1.3 8.8 2.6 5.4 1.3 8.4 2.3 4.6 1.2 7.6 1.9 97 15 120 255 7.3 0 7.3 7.3 10/04/2005 21:00:00 5.4 1 7.6 2.6 5.1 1 7.6 2.6 4.3 1 7.2 1.9 99 15 108 255 7.3 0 7.3 7.3 10/04/2005 21:10:00 4.9 0.8 6.8 2.6 4.7 0.9 6.8 2.3 4.2 0.9 6.5 1.5 99 15 81 255 7.2 0 7.3 7.3 10/04/2005 21:20:00 4.1 0.8 6.8 2.3 3.8 0.8 6.5 1.9 3.3 0.9 6.5 1.1 88 13 89 255 7.1 0 7.3 7 10/04/2005 21:30:00 4.4 0.8 6.5 2.3 4.1 0.9 6.5 1.9 3.6 1 5.7 1.9 91 14 78 255 7.1 0 7.3 7 10/04/2005 21:40:00 4.6 0.9 6.8 2.3 4.3 1 7.2 1.5 3.8 0.9 5.7 1.9 73 14 58 255 7.2 0 7.3 7 10/04/2005 21:50:00 4.5 0.9 6.5 2.3 4.3 0.9 6.1 1.9 3.5 1 6.1 1.5 82 13 77 255 7.1 0 7.3 7 10/04/2005 22:00:00 4.8 0.9 6.8 2.6 4.5 0.9 6.8 2.3 3.7 0.9 6.8 1.5 81 15 76 255 7.1 0 7.3 7 10/04/2005 22:10:00 5.1 1.1 8.4 2.6 4.9 1.1 8.4 2.3 3.9 1.1 6.5 1.5 79 13 73 255 7.3 0 7.3 7.3 10/04/2005 22:20:00 6 1.3 9.1 2.6 5.8 1.3 9.5 2.3 4.8 1.1 8.8 2.3 80 16 73 255 7.8 0.2 8.3 7.3 10/04/2005 22:30:00 5.2 1.2 8.8 3 4.9 1.2 9.5 2.6 4.3 1.2 7.2 1.9 78 17 69 255 8 0 8.3 7.8 10/04/2005 22:40:00 5.8 2.3 12.6 1.9 5.6 2.3 12.2 1.5 5.1 2 11.5 1.9 75 15 90 255 8 0 8.3 7.8 10/04/2005 22:50:00 5.8 1.5 10.7 1.9 5.6 1.5 9.9 1.5 4.7 1.6 9.5 1.5 80 17 68 255 8.1 0 8.3 8 10/04/2005 23:00:00 7.1 2 13.3 3 6.9 2 12.6 2.6 6 1.7 11.8 2.3 81 16 88 255 8 0 8.3 8 10/04/2005 23:10:00 6.7 1.7 12.6 3 6.5 1.7 11.5 2.6 5.5 1.5 9.1 2.3 84 17 100 255 8 0 8.3 7.8 10/04/2005 23:20:00 7.4 1.7 11.5 3 7.3 1.7 12.6 3.4 6 1.7 11.1 2.3 84 17 104 255 8 0 8.3 8 10/04/2005 23:30:00 8.3 2.3 14.9 3.4 8.2 2.3 14.9 3 7 2.1 13 2.6 80 15 69 255 8.1 0 8.3 8 10/04/2005 23:40:00 7.6 1.5 11.8 3.4 7.5 1.5 12.2 3 6.6 1.5 11.5 3 81 17 55 255 8.1 0 8.3 8 10/04/2005 23:50:00 7.9 1.9 13.7 2.6 7.8 1.9 13.7 3 6.5 1.8 13 2.6 83 19 106 255 8 0 8.3 7.8 10/05/2005 00:00:00 7.7 2 12.6 3.4 7.7 1.9 12.2 3.4 6.4 2.1 11.1 1.9 86 17 69 255 8 0 8.3 8 10/05/2005 00:10:00 8 2.6 14.5 2.3 7.9 2.6 14.9 3 6.9 2.5 13.3 2.3 80 16 72 255 8.2 0 8.5 8 10/05/2005 00:20:00 7.9 2.1 13 3 7.8 2.1 13 2.6 6.7 2 11.1 2.3 75 19 62 255 8.1 0 8.3 8 10/05/2005 00:30:00 8.8 2.1 15.6 4.6 8.8 2.1 15.3 3.8 7.3 2.1 13.3 3 83 15 89 255 8 0 8.3 8 10/05/2005 00:40:00 8.4 2.3 14.5 3.4 8.3 2.3 14.9 3 7.4 2.3 14.1 2.3 85 17 77 255 8 0 8.3 8 10/05/2005 00:50:00 8.2 2 15.3 3.4 8.1 2 14.1 3.8 6.9 2.1 14.1 3 84 20 62 255 8 0 8.3 8 10/05/2005 01:00:00 8 2.1 12.2 3 8.1 2 13 3.4 6.8 2.1 12.6 2.3 91 16 92 255 8.1 0 8.3 8 10/05/2005 01:10:00 6.6 2 11.8 1.9 6.5 2 11.8 2.3 5.5 2 10.3 1.1 87 20 77 255 8 0 8.3 7.8 10/05/2005 01:20:00 7.4 1.8 12.6 3.4 7.3 1.7 13 3 6 2 13 2.3 78 18 71 255 8.1 0 8.3 8 10/05/2005 01:30:00 7.8 2.1 13.7 3 7.7 2.1 13 2.6 6.8 2.1 12.6 2.3 80 18 97 255 8 0 8.3 7.8 10/05/2005 01:40:00 8.1 2.7 15.3 1.9 8.1 2.6 15.6 1.9 6.9 2.5 14.5 1.1 85 19 92 255 8 0 8.3 7.8 10/05/2005 01:50:00 7.8 2.8 14.9 1.5 7.7 2.8 14.9 1.5 6.6 2.7 14.5 1.5 86 19 84 255 8 0 8.3 7.8 10/05/2005 02:00:00 8.4 2.3 15.6 2.6 8.4 2.4 14.9 3 7.3 2.3 12.6 3 88 19 56 255 8 0 8.3 7.8 10/05/2005 02:10:00 7.3 2.3 12.6 3 7.2 2.3 12.6 3 6.3 2.3 13 2.3 86 18 81 255 8 0 8.3 8 10/05/2005 02:20:00 7.5 2.1 13 3.4 7.4 2.2 13.3 2.6 6.6 2 12.6 2.3 88 18 112 255 8 0 8.3 8 10/05/2005 02:30:00 7.5 1.9 12.2 3.4 7.5 2 12.2 3.8 6.4 1.9 11.5 2.3 91 17 95 255 8 0 8.3 8 10/05/2005 02:40:00 8 2.2 13.7 0.4 7.9 2.3 13.7 0.7 6.8 2.4 14.1 0.4 84 21 91 255 8.1 0 8.3 8 10/05/2005 02:50:00 7.6 2.3 14.1 3.4 7.5 2.2 14.1 3.4 6.3 2.1 11.5 1.9 81 20 79 255 8.1 0 8.3 8 10/05/2005 03:00:00 8.3 1.9 15.6 3.4 8.2 1.8 15.3 3.4 7 1.8 14.1 2.6 84 19 97 255 7.9 0 8 7.8 10/05/2005 03:10:00 11 2.4 16.8 5.3 11 2.4 16.8 5.7 9.6 2.5 16.1 4.2 85 16 79 255 8.1 0 8.3 7.8 10/05/2005 03:20:00 9.8 2.6 17.2 3 9.8 2.6 17.9 3.4 8.2 2.4 14.9 2.6 86 18 81 255 8.2 0 8.5 8 10/05/2005 03:30:00 9.5 2.3 16.1 4.6 9.4 2.3 15.3 3.8 7.8 2.4 13.3 2.6 87 17 62 255 8.3 0 8.5 8.3 10/05/2005 03:40:00 9.4 2.7 16.4 3.4 9.3 2.6 16.8 3 7.9 2.6 16.1 1.5 88 19 98 255 8.2 0 8.5 8.3 10/05/2005 03:50:00 10.3 2.8 19.1 3.4 10.3 2.8 18.7 3.4 8.6 2.5 16.8 2.6 92 19 100 255 8.4 0 8.5 8.3 10/05/2005 04:00:00 12.4 3.3 22.1 4.9 12.3 3.2 22.1 4.2 10.6 3.1 18.7 4.6 94 17 124 255 8.5 0.1 8.8 8.5 10/05/2005 04:10:00 10.2 2.5 21 4.6 10.1 2.5 20.2 4.9 8.5 2.6 16.1 1.9 92 18 83 255 8.5 0 8.8 8.5 10/05/2005 04:20:00 9.8 2.4 15.6 4.2 9.6 2.3 15.3 4.6 8.1 2.3 14.5 3.4 98 17 93 255 8.4 0 8.5 8.5 10/05/2005 04:30:00 11.1 2.9 18.7 4.9 10.9 2.9 19.1 4.9 9.7 2.7 16.8 3.8 100 16 70 255 8.4 0 8.5 8.3 10/05/2005 04:40:00 10.5 2.6 16.8 4.6 10.3 2.6 16.8 4.9 8.9 2.4 15.3 2.6 100 18 91 255 8.3 0 8.5 8.3 10/05/2005 04:50:00 10.8 3.2 18.7 4.2 10.6 3.2 18.7 3.4 8.8 3.1 17.2 2.6 100 18 102 255 8.2 0 8.3 8.3 10/05/2005 05:00:00 9.6 2.7 17.2 3.8 9.5 2.7 17.2 4.2 8 2.5 15.6 2.6 96 17 113 255 8.1 0 8.3 8 10/05/2005 05:10:00 10.1 2.6 18.3 4.2 10 2.5 17.6 4.2 8.3 2.6 16.4 3.4 98 19 108 255 8.1 0 8.3 8 10/05/2005 05:20:00 10 2.6 18.3 4.9 9.9 2.6 18.3 4.2 8.4 2.4 16.8 3 96 19 108 255 8.1 0 8.3 8 10/05/2005 05:30:00 10.3 2.6 18.3 5.3 10.2 2.5 17.9 5.3 8.7 2.6 17.6 2.6 97 20 93 255 8.2 0 8.3 8.3 10/05/2005 05:40:00 9.7 2.8 16.8 2.3 9.6 2.8 16.4 2.3 8.5 2.6 14.5 2.3 97 18 90 255 8 0 8.3 7.8 10/05/2005 05:50:00 8.8 2.2 14.1 3.8 8.7 2.3 13.7 3 7.6 2.1 13 1.5 93 19 90 255 8 0 8 7.8 10/05/2005 06:00:00 9.6 2.9 17.2 3.4 9.5 2.9 16.8 3.4 8.2 2.7 15.3 1.9 93 18 122 255 7.9 0 8 7.8 10/05/2005 06:10:00 9.7 2.2 16.1 3.8 9.6 2.1 14.5 4.6 8.3 2.1 13 2.6 99 18 105 255 7.8 0 8 7.8 10/05/2005 06:20:00 9.5 2.4 16.4 4.6 9.4 2.3 16.1 4.6 7.8 2.1 15.3 1.9 100 21 124 255 7.8 0 8 7.8 10/05/2005 06:30:00 10.2 2.7 17.2 4.2 10 2.7 17.2 4.2 8.7 2.5 15.3 3.8 94 19 88 255 8 0 8.3 7.8 10/05/2005 06:40:00 9.7 2.4 16.4 4.2 9.6 2.3 16.4 4.6 8.2 2.2 13.7 2.6 95 20 69 255 8 0 8.3 7.8 10/05/2005 06:50:00 10.4 3.1 19.5 4.2 10.2 3.1 19.1 3.8 8.7 2.9 16.4 3 95 19 94 255 8.1 0 8.3 8 10/05/2005 07:00:00 10.5 2.5 16.1 4.9 10.4 2.5 16.1 3.8 9 2.4 14.9 3.4 96 16 77 255 8 0 8.3 8 10/05/2005 07:10:00 10.3 2 16.4 4.6 10.2 2 16.4 4.9 8.7 2.1 14.1 2.6 93 18 88 255 8 0 8.3 7.8 10/05/2005 07:20:00 10.4 2.6 16.8 3 10.2 2.6 17.2 3 9.1 2.4 15.6 3.4 95 17 96 255 8 0 8.3 7.8 10/05/2005 07:30:00 10.9 2.8 19.1 4.2 10.7 2.8 19.1 4.2 9.2 2.6 16.8 3.4 94 20 88 255 8 0 8.3 7.8 10/05/2005 07:40:00 10.3 2.7 16.8 3 10.3 2.7 16.8 4.2 8.7 2.8 15.6 2.3 94 19 110 255 8 0 8.3 7.8 10/05/2005 07:50:00 9 2.8 17.2 3 8.9 2.7 16.1 3 7.5 2.7 14.1 1.5 92 22 84 255 8 0 8.3 8 10/05/2005 08:00:00 9.5 2.4 16.1 3.8 9.4 2.4 15.6 3.8 8 2.3 14.1 3.4 92 19 79 255 8.1 0 8.3 8 10/05/2005 08:10:00 11 2.5 17.6 4.9 11 2.5 16.8 4.6 9.4 2.4 16.1 4.6 95 15 95 255 8.1 0 8.3 8 10/05/2005 08:20:00 9.8 3.1 19.5 3.4 9.7 2.9 17.9 2.6 8.1 3.2 19.1 1.5 94 21 88 255 8.1 0 8.3 8 10/05/2005 08:30:00 10.4 2.6 18.3 4.6 10.4 2.5 17.9 4.2 8.8 2.6 16.8 3.4 94 19 91 255 8.1 0 8.3 8.3 10/05/2005 08:40:00 10.7 2.6 18.7 4.9 10.7 2.6 17.9 4.9 9.4 2.8 16.1 3 93 17 85 255 8.3 0 8.3 8.3 10/05/2005 08:50:00 10.5 2.6 17.2 3.8 10.4 2.6 17.2 4.2 8.8 2.6 15.6 3 97 22 98 255 8.4 0 8.5 8.3 10/05/2005 09:00:00 10.9 2.9 17.6 3 10.8 2.9 17.6 3.4 9.4 2.8 15.6 2.6 94 17 99 255 8.4 0 8.5 8.5 10/05/2005 09:10:00 10.1 2.6 17.9 4.9 9.9 2.6 18.3 4.6 8.5 2.6 17.6 3 94 17 103 255 8.4 0 8.5 8.5 10/05/2005 09:20:00 10.3 3.2 18.7 3.8 10.3 3.1 18.7 4.2 8.8 2.8 17.6 2.6 94 20 88 255 8.5 0 8.5 8.5 10/05/2005 09:30:00 10.2 2.4 16.1 4.9 10 2.4 16.1 4.2 8.7 2.4 16.1 4.2 96 17 80 255 8.6 0 8.8 8.5 10/05/2005 09:40:00 10.2 2.5 16.8 3.4 10 2.5 16.4 3 8.4 2.5 14.5 2.6 94 20 94 255 8.6 0 8.8 8.5 10/05/2005 09:50:00 8.9 2.8 16.4 2.6 8.9 2.7 16.4 2.6 7.8 2.4 13.3 2.6 93 18 100 255 8.6 0 8.8 8.5 10/05/2005 10:00:00 9.8 2.5 16.4 3.8 9.6 2.5 16.1 3.4 8.3 2.5 14.9 3 92 17 97 255 8.7 0 8.8 8.5 10/05/2005 10:10:00 9.8 2.8 16.8 3.4 9.8 2.8 16.4 3.8 8.3 2.8 16.1 2.6 95 17 91 255 8.9 0 9 8.8 10/05/2005 10:20:00 9.7 2.4 16.8 3.8 9.6 2.4 15.6 3 8.5 2.5 14.9 3 95 18 97 255 9 0 9.3 9 10/05/2005 10:30:00 9.7 2.6 17.6 4.2 9.5 2.6 17.6 3.4 8.2 2.4 16.4 2.6 95 17 95 255 9.2 0 9.6 9 10/05/2005 10:40:00 9.4 2.1 16.1 3.8 9.2 2 15.3 4.6 8 2.1 14.1 1.9 93 19 86 255 9.4 0 9.6 9.3 10/05/2005 10:50:00 9.4 2.4 16.1 3 9.2 2.4 15.6 3 7.7 2.5 13.7 2.3 93 18 86 255 9.7 0 9.8 9.6 10/05/2005 11:00:00 9.4 2.8 17.2 3 9.3 2.8 16.4 3.8 8.3 2.7 16.4 2.6 92 20 94 255 9.7 0 9.8 9.6 10/05/2005 11:10:00 9.7 2.2 16.4 4.6 9.6 2.2 16.4 4.6 8.2 2.2 15.3 3.8 93 17 85 255 9.6 0 9.8 9.6 10/05/2005 11:20:00 9.4 2.3 16.1 4.2 9.3 2.3 16.4 4.2 8 2.3 14.9 3.4 93 18 92 255 9.8 0 9.8 9.6 10/05/2005 11:30:00 9.5 2.3 16.1 3.8 9.4 2.2 16.1 4.2 8.1 2.1 14.5 4.2 91 17 100 255 10 0 10.1 9.8 10/05/2005 11:40:00 8.8 2.4 14.1 3.4 8.7 2.4 14.5 2.6 7.4 2.4 13 2.6 95 19 100 255 10.1 0 10.3 9.8 10/05/2005 11:50:00 8.1 2.4 15.3 3.4 7.9 2.4 15.3 3.4 6.9 2.3 12.6 1.9 97 20 97 255 10.3 0 10.6 10.3 10/05/2005 12:00:00 9 2.5 17.2 3.8 8.8 2.5 16.8 3.4 7.6 2.3 13 3.4 97 19 100 255 10.7 0 10.9 10.6 10/05/2005 12:10:00 9.3 2.6 18.3 4.6 9.3 2.6 19.1 3.4 8.1 2.4 17.2 3.4 98 17 102 255 11 0.1 11.4 10.9 10/05/2005 12:20:00 9.5 2.4 15.3 3.4 9.4 2.4 15.3 3.4 8.1 2.3 13.7 3.4 96 17 84 255 11.6 0.2 11.9 11.4 10/05/2005 12:30:00 8.7 2.4 14.5 3.4 8.5 2.3 14.1 3.4 7.4 2.3 14.1 3 95 20 85 255 11.7 0 11.9 11.7 10/05/2005 12:40:00 8.9 2.3 14.9 4.2 8.8 2.4 14.5 3.8 7.7 2.5 14.1 2.3 94 17 86 255 11.5 0 11.7 11.4 10/05/2005 12:50:00 8.6 2.3 15.6 3.4 8.5 2.2 16.1 4.2 7.4 2.3 14.5 1.9 92 21 107 255 11.3 0 11.7 11.1 10/05/2005 13:00:00 8.8 2.2 16.1 3.8 8.8 2.2 16.8 4.2 7.6 2.2 13.7 2.6 92 18 100 255 11.2 0 11.4 11.1 10/05/2005 13:10:00 9.2 2.8 16.8 3 9 2.8 17.2 3 7.8 2.6 14.9 1.9 91 19 80 255 11.1 0 11.4 11.1 10/05/2005 13:20:00 9.1 2.3 16.1 3 9 2.3 15.3 3 7.7 2.1 13.3 2.6 95 17 60 255 11.1 0 11.1 10.9 10/05/2005 13:30:00 8.8 2.4 14.5 3.4 8.8 2.4 14.5 3.4 7.5 2.3 13.3 3 97 17 91 255 11 0 11.1 10.9 10/05/2005 13:40:00 8.4 2.1 13.7 3.8 8.3 2 13.7 3.4 7.5 1.9 11.8 2.3 94 17 83 255 11.1 0 11.1 10.9 10/05/2005 13:50:00 8.9 2.6 15.3 3.4 8.7 2.5 15.3 3.4 7.5 2.5 14.5 3 94 17 109 255 11.1 0 11.1 11.1 10/05/2005 14:00:00 9 2.2 16.4 3 8.9 2.2 16.8 3.4 7.6 2 13.3 2.6 90 19 89 255 11.1 0 11.1 11.1 10/05/2005 14:10:00 9.8 2.3 16.1 3.8 9.7 2.3 15.3 4.6 8.4 2.2 14.5 3.8 93 17 151 255 11.1 0 11.4 11.1 10/05/2005 14:20:00 8.4 2.4 14.5 3.4 8.3 2.3 14.1 3.8 7.2 2.2 13 2.6 91 21 105 255 11.3 0 11.4 11.1 10/05/2005 14:30:00 8.3 2.2 14.5 3 8.2 2.2 13.7 3 7.1 2 13.3 2.6 91 19 83 255 11.3 0 11.4 11.1 10/05/2005 14:40:00 8.5 2 13.7 3.4 8.4 2.1 13.7 3.4 7.3 1.9 12.6 3 88 17 72 255 11.3 0 11.4 11.4 10/05/2005 14:50:00 8 2.4 14.5 3.4 7.9 2.4 14.1 3 6.9 2.2 13.7 2.3 86 16 94 255 11.3 0 11.4 11.1 10/05/2005 15:00:00 8.7 2.1 14.1 3.8 8.6 2.2 14.1 4.2 7.5 2.1 12.6 3.4 89 18 108 255 11.5 0 11.7 11.4 10/05/2005 15:10:00 8.2 2.1 13.3 2.3 8.1 2.1 13 1.9 7.1 1.8 12.2 2.6 90 16 117 255 11.5 0 11.7 11.4 10/05/2005 15:20:00 8.5 1.9 13.7 1.9 8.4 1.9 14.1 3 7.2 2 12.2 1.5 84 17 73 255 11.5 0 11.7 11.4 10/05/2005 15:30:00 8.4 2.3 13.3 2.6 8.3 2.3 13 2.6 7.1 2.1 12.6 1.5 86 17 93 255 11.7 0 11.7 11.7 10/05/2005 15:40:00 7.7 1.9 14.1 3 7.6 1.9 14.1 3 6.3 1.7 12.6 2.3 90 20 102 255 11.7 0 11.9 11.7 10/05/2005 15:50:00 8.5 2 14.1 3.4 8.4 2 14.1 3.8 7.1 1.7 12.2 2.6 85 17 101 255 11.5 0 11.7 11.4 10/05/2005 16:00:00 8 1.7 13 3.8 7.9 1.7 13 3.8 6.9 1.7 12.2 3 88 15 79 255 11.5 0 11.7 11.4 10/05/2005 16:10:00 7.9 1.7 12.2 3.4 7.7 1.7 11.8 3 6.8 1.7 11.5 2.3 93 14 94 255 11.5 0 11.7 11.4 10/05/2005 16:20:00 7 1.5 11.1 3.4 6.9 1.5 10.7 2.6 5.8 1.5 10.3 1.9 95 15 90 255 11.3 0 11.7 11.1 10/05/2005 16:30:00 6.9 1.5 10.7 3.4 6.7 1.4 9.9 3.4 5.6 1.5 10.3 1.5 92 17 112 255 11.1 0 11.1 11.1 10/05/2005 16:40:00 6.8 1.6 11.1 2.6 6.7 1.5 10.3 2.6 5.9 1.6 9.5 1.9 98 15 100 255 10.9 0.1 11.1 10.6 10/05/2005 16:50:00 6.2 1.4 9.9 3.4 6.1 1.5 9.9 2.3 5.3 1.4 9.5 2.3 88 15 109 255 10.5 0 10.6 10.6 10/05/2005 17:00:00 7 1.5 10.7 2.3 6.8 1.5 10.7 2.3 5.7 1.5 9.1 1.9 90 16 93 255 10.3 0 10.6 10.3 10/05/2005 17:10:00 6.3 1.5 10.7 2.6 6.2 1.5 11.1 2.6 5.1 1.6 9.1 1.1 84 17 93 255 10.2 0 10.3 10.1 10/05/2005 17:20:00 6.8 1.7 11.1 2.6 6.7 1.7 10.7 2.6 5.6 1.7 10.3 1.9 94 17 101 255 10 0 10.1 9.8 10/05/2005 17:30:00 7.4 1.3 10.7 3.8 7.2 1.3 10.3 3.8 6.3 1.5 9.9 2.6 95 15 102 255 9.8 0 9.8 9.6 10/05/2005 17:40:00 7.1 1.8 11.1 2.3 6.9 1.8 10.7 1.9 5.9 1.7 11.1 1.9 94 15 97 255 9.6 0 9.8 9.6 10/05/2005 17:50:00 7.6 1.7 12.2 3 7.5 1.8 12.6 3 6.4 1.7 11.1 1.9 91 14 96 255 9.5 0 9.6 9.6 10/05/2005 18:00:00 6.5 1.6 10.3 2.6 6.4 1.5 10.3 2.6 5.3 1.3 9.1 1.9 84 17 96 255 9.4 0 9.6 9.3 10/05/2005 18:10:00 7.2 1.5 10.7 2.6 7.1 1.5 10.3 2.6 5.9 1.5 9.1 1.5 75 14 83 255 9.4 0 9.6 9.3 10/05/2005 18:20:00 5.9 1.3 9.5 3 5.6 1.3 9.1 3 4.9 1.3 8.4 2.3 91 17 88 255 9.4 0 9.6 9.3 10/05/2005 18:30:00 5.8 1.7 9.1 1.5 5.6 1.7 9.5 0.4 4.8 1.7 9.1 1.1 96 18 74 255 9.2 0 9.3 9.3 10/05/2005 18:40:00 6.1 1.4 11.1 3 6 1.4 10.3 2.6 5.3 1.4 9.5 1.5 90 17 96 255 9.2 0 9.3 9 10/05/2005 18:50:00 4.6 1.3 8.4 1.1 4.5 1.3 8 1.9 3.8 1.5 8.4 0.4 76 22 89 255 8.9 0 9 8.8 10/05/2005 19:00:00 5.9 1.3 9.1 3 5.8 1.3 9.1 2.6 5.1 1.2 8.4 2.3 89 16 103 255 8.9 0 9 8.8 10/05/2005 19:10:00 5.9 1.4 9.1 2.6 5.8 1.5 9.1 1.9 5 1.4 8.4 1.9 96 14 113 255 8.7 0 8.8 8.5 10/05/2005 19:20:00 6 1.1 8.8 3 5.8 1.2 8.8 3 5 1.2 8.4 1.5 103 13 88 255 8.5 0 8.8 8.5 10/05/2005 19:30:00 5.8 1.2 9.1 3 5.6 1.2 8.4 2.6 4.7 1.2 7.6 2.3 109 14 119 255 8.5 0 8.8 8.5 10/05/2005 19:40:00 6.5 1.2 9.9 3 6.2 1.2 9.5 3 5.3 1.2 8.8 2.6 114 15 134 255 8.5 0 8.8 8.5 10/05/2005 19:50:00 6.4 1.2 9.9 3.4 6.2 1.2 9.5 3 5.2 1.1 7.6 2.6 105 14 86 255 8.5 0 8.5 8.5 10/05/2005 20:00:00 7 1.7 11.5 2.6 6.8 1.7 11.1 3.4 5.6 1.7 10.7 1.9 104 16 113 255 8.4 0 8.5 8.5 10/05/2005 20:10:00 8.3 1.5 12.6 4.6 8.1 1.5 11.8 4.2 7.1 1.7 11.5 3.4 102 14 113 255 8.5 0 8.8 8.5 10/05/2005 20:20:00 7.2 1.7 10.7 3 7.1 1.7 10.7 3 6.1 1.5 9.5 1.9 99 17 93 255 8.4 0 8.5 8.3 10/05/2005 20:30:00 8 1.7 12.2 2.6 7.9 1.7 11.8 2.6 6.8 1.9 12.6 2.6 102 16 95 255 8.5 0 8.8 8.5 10/05/2005 20:40:00 8 1.7 13 3.4 7.9 1.7 12.6 3 6.6 1.7 12.2 1.9 99 15 81 255 8.5 0 8.5 8.5 10/05/2005 20:50:00 7.1 1.7 11.8 2.6 6.9 1.7 11.5 2.6 6 1.5 9.9 1.9 97 15 99 255 8.5 0 8.5 8.5 10/05/2005 21:00:00 6.8 1.4 11.5 3.8 6.6 1.4 11.8 3.4 5.6 1.3 9.5 2.6 93 15 102 255 8.6 0 8.8 8.5 10/05/2005 21:10:00 5.9 1.4 10.3 2.6 5.6 1.4 9.9 2.3 4.8 1.3 9.9 1.9 96 17 92 255 8.5 0 8.8 8.5 10/05/2005 21:20:00 5.7 1.5 9.1 2.6 5.4 1.5 9.1 2.3 4.8 1.5 8.4 1.9 98 19 92 255 8.4 0 8.5 8.5 10/05/2005 21:30:00 5.7 1.3 8.4 2.3 5.5 1.3 8.4 1.9 4.9 1.3 8.4 1.1 100 14 122 255 8.3 0 8.5 8.3 10/05/2005 21:40:00 5.6 1.3 9.1 2.3 5.4 1.3 8.8 2.3 4.4 1.2 7.6 1.9 106 16 115 255 8.3 0 8.5 8.3 10/05/2005 21:50:00 6 1.7 11.5 2.3 5.8 1.7 11.1 2.3 5.1 1.6 10.3 1.1 103 15 91 255 8.3 0 8.5 8.3 10/05/2005 22:00:00 6.5 1.4 11.1 3.8 6.3 1.3 10.7 3.4 5.5 1.4 11.1 3 96 17 94 255 8.1 0 8.5 8 10/05/2005 22:10:00 6.7 1.3 10.3 3.4 6.5 1.3 9.5 3.4 5.5 1.3 8.8 1.5 96 15 98 255 8 0 8.3 8 10/05/2005 22:20:00 6.2 1.3 9.1 2.6 6 1.3 8.8 2.6 5 1.4 8 1.1 91 17 85 255 8 0 8.3 7.8 10/05/2005 22:30:00 5.8 1.3 8.8 2.6 5.7 1.3 8.8 2.3 4.8 1.4 8.4 1.1 99 15 93 255 8.1 0 8.3 8 10/05/2005 22:40:00 6.7 1.3 10.3 3.8 6.5 1.3 10.3 3.4 5.6 1.2 8.8 1.9 103 12 105 255 8 0 8.3 7.8 10/05/2005 22:50:00 7 1.3 10.7 3.4 6.9 1.3 9.9 3.4 5.7 1.3 9.5 2.3 105 15 111 255 7.9 0 8 7.8 10/05/2005 23:00:00 7.2 1.6 11.5 2.3 7 1.6 11.5 2.6 6 1.5 9.9 2.6 108 15 106 255 7.9 0 8 7.8 10/05/2005 23:10:00 6.9 1.2 9.5 3.4 6.8 1.2 9.5 3.8 5.8 1.3 9.5 2.6 99 12 108 255 8 0 8.3 7.8 10/05/2005 23:20:00 5.3 1.4 9.1 2.3 5.2 1.3 8.8 2.3 4.4 1.3 8.8 1.5 89 17 76 255 8.1 0 8.3 8 10/05/2005 23:30:00 5.8 1 8.4 3 5.5 1 8 2.3 4.6 1 8 2.3 101 12 105 255 8.1 0 8.3 8 10/05/2005 23:40:00 5.7 1.2 8.8 3.4 5.5 1.1 8.4 3.4 4.7 1.2 8 1.5 110 17 101 255 8.1 0 8.3 8 10/05/2005 23:50:00 6.2 1.3 9.1 2.3 6 1.3 9.1 2.6 5.1 1.3 8 1.9 109 13 134 255 8.1 0 8.3 8 10/06/2005 00:00:00 5.9 1.1 8.8 2.6 5.8 1.1 8.8 3 4.8 1.1 7.6 2.6 109 15 94 255 8.1 0 8.5 8 10/06/2005 00:10:00 5.9 1.3 9.5 1.9 5.6 1.3 9.1 2.3 4.9 1.2 8.4 1.9 107 18 99 255 8.3 0 8.3 8.3 10/06/2005 00:20:00 6 1.3 9.1 2.3 5.8 1.2 9.1 2.6 5.1 1.2 8.4 1.9 106 15 89 255 8.3 0 8.5 8.3 10/06/2005 00:30:00 6.7 1.2 9.5 3 6.5 1.2 9.5 3.4 5.5 1.2 8.4 2.3 105 13 100 255 8.3 0 8.5 8.3 10/06/2005 00:40:00 5.4 1.5 10.3 2.3 5.2 1.5 10.3 1.9 4.5 1.3 8.8 1.1 105 17 118 255 8.1 0 8.3 8 10/06/2005 00:50:00 5.4 1.3 8.8 2.6 5.2 1.3 8.4 2.3 4.3 1.5 7.6 0.4 108 19 88 255 8.1 0 8.3 8 10/06/2005 01:00:00 5.4 1.1 8.8 2.6 5.3 1.1 8.8 2.3 4.3 1.3 7.6 1.5 103 16 98 255 8.1 0 8.3 8 10/06/2005 01:10:00 3.9 1 6.1 1.1 3.7 1 6.1 0.7 3.1 1 5.3 0.7 99 17 112 255 8 0 8.3 8 10/06/2005 01:20:00 4.2 1 6.5 1.9 4.1 1.1 7.2 1.9 3.3 1 6.1 0.7 101 16 112 255 8 0 8.3 7.8 10/06/2005 01:30:00 4.8 1.1 8.4 2.3 4.5 1.1 8 1.9 3.8 1.1 6.5 0.7 104 15 84 255 8.1 0 8.3 8 10/06/2005 01:40:00 4.5 1 6.8 2.3 4.3 1 6.5 1.9 3.4 1 5.3 0.4 111 15 123 255 8.2 0 8.3 8.3 10/06/2005 01:50:00 4.8 1.1 7.6 1.5 4.6 1.1 7.2 1.5 3.9 1 6.8 1.1 110 16 111 255 8.3 0 8.5 8.3 10/06/2005 02:00:00 4.7 1.2 9.1 2.3 4.6 1.3 9.1 2.3 4 1.4 9.5 1.5 98 17 116 255 8.4 0 8.5 8.3 10/06/2005 02:10:00 5.6 1.2 9.1 2.3 5.4 1.2 8.8 1.9 4.7 1.3 8.4 1.1 94 12 111 255 8.3 0 8.5 8.3 10/06/2005 02:20:00 5.7 1.3 9.1 2.3 5.5 1.2 8.8 2.3 4.5 1.2 7.2 1.1 98 15 111 255 8.1 0 8.3 8 10/06/2005 02:30:00 6.7 1.2 10.3 3.4 6.4 1.2 10.3 3.4 5.4 1.3 8.4 2.6 97 12 84 255 8 0 8 7.8 10/06/2005 02:40:00 5.3 1.3 9.5 1.9 5.2 1.3 9.1 1.9 4.5 1.2 8.4 1.9 100 15 88 255 7.8 0 7.8 7.8 10/06/2005 02:50:00 5.7 1.4 9.1 2.3 5.6 1.4 9.1 1.9 4.7 1.3 8 1.9 99 15 128 255 7.7 0 7.8 7.5 10/06/2005 03:00:00 5.9 1.1 8.8 3 5.8 1.1 8.8 3 5.1 1.2 8 1.9 100 13 97 255 7.4 0 7.5 7.5 10/06/2005 03:10:00 5.3 1.2 8.8 3 5.2 1.2 8.8 2.3 4.5 1.1 7.6 1.9 100 14 111 255 7.5 0 7.5 7.3 10/06/2005 03:20:00 5.3 1.3 8.4 2.3 5.1 1.3 7.6 1.1 4.3 1.3 7.2 1.5 106 16 98 255 7.4 0.1 7.5 7.3 10/06/2005 03:30:00 4.7 1 7.2 2.6 4.6 1 7.2 1.5 3.8 1 6.8 1.1 105 17 109 255 7.3 0 7.3 7.3 10/06/2005 03:40:00 5 1 7.2 3 4.8 1 7.6 2.6 4.2 1 7.2 1.9 108 15 116 255 7.3 0 7.5 7.3 10/06/2005 03:50:00 5.3 1 7.6 2.6 5.2 1 7.6 2.3 4.3 1 6.8 1.5 108 13 105 255 7.3 0 7.5 7.3 10/06/2005 04:00:00 5.3 1.1 7.6 2.3 5.2 1 7.2 2.3 4.5 1.1 7.6 1.5 101 12 113 255 7.3 0 7.5 7.3 10/06/2005 04:10:00 5.6 1 7.6 2.6 5.5 1 7.6 2.6 4.3 1 6.8 2.3 101 13 99 255 7.3 0 7.5 7.3 10/06/2005 04:20:00 5.6 1.3 8.8 3 5.5 1.3 8.4 2.6 4.8 1.3 8.8 1.9 96 13 102 255 7.5 0 7.8 7.3 10/06/2005 04:30:00 5.8 1.1 9.1 3 5.7 1.1 9.1 2.6 4.7 1.1 8 1.9 99 12 107 255 7.6 0 7.8 7.5 10/06/2005 04:40:00 5 1 7.6 2.3 4.9 1 7.2 2.3 4.2 1 6.1 1.9 98 12 75 255 7.6 0 7.8 7.5 10/06/2005 04:50:00 4.9 1 7.6 2.3 4.7 1 6.8 2.3 3.9 1 6.1 1.9 104 15 105 255 7.7 0 7.8 7.5 10/06/2005 05:00:00 3.9 1 6.5 1.5 3.7 1 5.7 1.5 3.1 1.1 5.7 0.4 105 17 115 255 7.7 0 7.8 7.5 10/06/2005 05:10:00 4.6 1.2 7.6 1.9 4.3 1.1 7.6 1.5 3.6 1.1 6.5 1.5 108 15 121 255 7.8 0 7.8 7.5 10/06/2005 05:20:00 4.9 1 7.2 3 4.6 1 7.2 2.6 3.9 1 6.1 1.9 108 15 109 255 7.8 0 7.8 7.8 10/06/2005 05:30:00 5 1.1 8 1.9 4.8 1.1 8 1.9 3.9 1.2 7.6 1.5 108 15 90 255 8 0 8 7.8 10/06/2005 05:40:00 4.9 1 6.8 1.9 4.6 1 6.5 1.5 4 1.1 6.8 1.1 105 17 134 255 8 0 8.3 7.8 10/06/2005 05:50:00 4.9 1.3 7.6 1.9 4.7 1.3 7.6 1.5 3.8 1.2 6.8 0.7 111 15 100 255 7.8 0 8 7.8 10/06/2005 06:00:00 5.1 1 7.2 2.6 4.9 1 6.8 2.3 4.1 1 6.5 1.9 109 14 106 255 7.6 0 7.8 7.3 10/06/2005 06:10:00 4.4 0.9 6.8 2.3 4.1 0.9 6.8 1.9 3.4 0.9 6.1 1.1 108 13 94 255 7.3 0 7.5 7 10/06/2005 06:20:00 4.3 0.9 6.5 2.3 4.1 0.9 6.1 2.3 3.4 0.9 6.1 1.5 103 15 100 255 7.1 0 7.3 7 10/06/2005 06:30:00 4.2 0.8 6.5 2.3 3.9 0.8 6.5 1.9 3.3 0.8 5.7 0.4 100 13 94 255 7.3 0 7.3 7.3 10/06/2005 06:40:00 3.9 0.9 6.1 1.9 3.8 0.8 5.7 1.5 3.1 0.8 5.7 0.7 97 13 94 255 7.3 0 7.3 7.3 10/06/2005 06:50:00 4.8 1.1 7.6 1.1 4.6 1.1 7.6 1.1 4.1 1 6.5 1.1 101 12 101 255 7.3 0 7.5 7.3 10/06/2005 07:00:00 4.9 0.8 6.8 3 4.7 0.8 6.8 2.6 3.8 1 6.8 1.5 107 13 108 255 7.6 0 7.8 7.5 10/06/2005 07:10:00 4.3 0.9 6.8 2.3 4 0.9 6.5 1.9 3.3 1 6.5 0.7 102 13 78 255 7.6 0 7.5 7.5 10/06/2005 07:20:00 3.4 1.3 6.1 1.1 3.2 1.3 6.1 0.4 2.6 1.3 5.3 0.4 95 23 112 255 7.6 0 7.8 7.5 10/06/2005 07:30:00 1.4 0.7 3.4 0.4 1 0.7 3 0.4 0.9 0.6 2.6 0.4 40 30 99 255 7.5 0 7.8 7.3 10/06/2005 07:40:00 1.1 0.5 3 0.4 0.7 0.5 3 0.4 0.6 0.4 2.3 0.4 14 23 49 255 7 0.1 7.3 6.7 10/06/2005 07:50:00 0.4 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 358 14 346 255 6.4 0.2 6.7 6.2 10/06/2005 08:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 298 14 296 255 6.2 0 6.2 6.2 10/06/2005 08:10:00 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 346 45 296 255 6.1 0 6.2 6 10/06/2005 08:20:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 346 30 359 255 6 0 6 5.7 10/06/2005 08:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 356 56 49 255 5.8 0 6 5.7 10/06/2005 08:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 0 34 255 5.7 0 5.7 5.7 10/06/2005 08:50:00 0.5 0.3 2.3 0.4 0.4 0.2 1.9 0.4 0.4 0 0.4 0.4 32 8 63 255 5.5 0 5.7 5.2 10/06/2005 09:00:00 1.7 0.7 3 0.4 1.5 0.7 2.6 0.4 0.8 0.5 1.9 0.4 40 13 49 255 5.2 0 5.5 5 10/06/2005 09:10:00 1.6 0.4 2.6 0.4 1.1 0.4 2.3 0.4 0.4 0.2 1.5 0.4 42 6 37 255 5 0 5.2 4.8 10/06/2005 09:20:00 1.7 0.3 2.3 1.1 1.2 0.4 2.3 0.4 0.6 0.4 1.9 0.4 20 10 35 255 4.8 0 4.8 4.5 10/06/2005 09:30:00 1.7 0.4 2.3 0.7 1.3 0.4 2.3 0.4 0.7 0.3 1.5 0.4 35 7 19 255 4.6 0 4.8 4.5 10/06/2005 09:40:00 2 0.3 2.6 1.5 1.7 0.3 2.6 1.1 1.2 0.4 2.3 0.4 38 5 39 255 5 0.2 5.5 4.5 10/06/2005 09:50:00 2 0.4 3 1.1 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 18 15 42 255 5.7 0.1 6 5.5 10/06/2005 10:00:00 1.4 0.3 1.9 0.7 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 359 4 7 255 6.1 0 6.2 6 10/06/2005 10:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 357 255 6.3 0 6.7 6.2 10/06/2005 10:20:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 357 0 357 255 6.7 0.1 7 6.5 10/06/2005 10:30:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 32 15 37 255 7.1 0 7.3 7 10/06/2005 10:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 35 0 35 255 7.4 0 7.8 7.3 10/06/2005 10:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 43 13 35 255 8 0.1 8.5 7.8 10/06/2005 11:00:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 45 12 66 255 8.6 0 9 8.3 10/06/2005 11:10:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 41 11 57 255 9.2 0.1 9.6 9 10/06/2005 11:20:00 1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 53 29 74 255 10 0.3 10.6 9.6 10/06/2005 11:30:00 1.1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 27 30 4 255 11.2 0.1 11.7 10.6 10/06/2005 11:40:00 1.1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.7 0.3 1.5 0.4 11 15 39 255 11.8 0.1 11.9 11.4 10/06/2005 11:50:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 29 16 73 255 11.8 0.1 12.2 11.7 10/06/2005 12:00:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 48 27 41 255 11.5 0 11.7 11.4 10/06/2005 12:10:00 1.1 0.4 2.3 0.4 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 58 17 50 255 12.3 0.3 12.7 11.7 10/06/2005 12:20:00 1.5 0.5 3 0.4 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 14 22 13 255 13.1 0.2 13.5 12.7 10/06/2005 12:30:00 2.1 0.6 3.8 0.4 1.5 0.7 3.4 0.4 1.5 0.8 2.6 0.4 340 15 348 255 13.4 0 13.5 13 10/06/2005 12:40:00 2.3 0.7 3.8 0.7 1.7 0.8 3.4 0.4 1.6 1 3.4 0.4 330 15 346 255 12.5 0.2 13 11.9 10/06/2005 12:50:00 2.5 0.6 3.8 0.7 2 0.7 3.4 0.4 1.5 0.8 3 0.4 340 15 342 255 11.9 0 12.2 11.7 10/06/2005 13:00:00 2.4 0.4 3.4 1.1 2.1 0.5 3 0.7 2 0.5 3 0.4 301 10 298 255 11.5 0 11.7 11.4 10/06/2005 13:10:00 1.8 0.6 3 0.4 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 297 23 282 255 12.7 0.6 13.5 11.7 10/06/2005 13:20:00 1.2 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 294 61 5 255 14 0.3 14.9 13.3 10/06/2005 13:30:00 1.7 0.6 3.4 0.4 1.3 0.6 3.4 0.4 1.3 0.5 3 0.4 9 17 28 255 14.8 0 15.2 14.6 10/06/2005 13:40:00 2.1 0.7 4.2 0.4 1.9 0.8 4.2 0.4 1.8 0.8 3.8 0.4 328 36 310 255 14.8 0 15.2 14.6 10/06/2005 13:50:00 2.1 0.7 3.4 0.4 2 0.8 3.8 0.4 1.5 0.8 3.4 0.4 297 19 314 255 15.2 0.2 16 14.9 10/06/2005 14:00:00 1.7 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.1 0.6 3 0.4 300 28 283 255 14.4 0.4 15.2 13.5 10/06/2005 14:10:00 2.5 0.5 4.2 1.1 2.5 0.5 3.8 1.1 2.2 0.6 3.4 0.4 305 12 304 255 13.2 0.2 13.5 12.7 10/06/2005 14:20:00 1.9 0.6 3 0.4 1.9 0.6 3 0.7 1.4 0.8 3 0.4 309 14 316 255 12.5 0.1 13.3 12.2 10/06/2005 14:30:00 2.1 0.4 3 0.7 2.2 0.4 3 0.7 1.8 0.6 3 0.4 299 10 294 255 11.9 0.2 12.7 11.7 10/06/2005 14:40:00 1.7 0.4 3 0.7 1.8 0.4 3 0.4 1.3 0.5 2.3 0.4 300 14 313 255 11.3 0.1 11.9 10.9 10/06/2005 14:50:00 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.7 0.3 1.9 0.4 283 11 287 255 10.8 0.1 11.4 10.6 10/06/2005 15:00:00 0.8 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 268 12 283 255 10.5 0 11.1 10.3 10/06/2005 15:10:00 0.9 0.4 1.5 0.4 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 281 5 280 255 10.2 0 10.3 10.1 10/06/2005 15:20:00 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 308 19 284 255 10.5 0 10.9 10.3 10/06/2005 15:30:00 1.2 0.6 3 0.4 1.2 0.6 3 0.4 1 0.6 2.6 0.4 307 19 312 255 10.6 0 10.9 10.6 10/06/2005 15:40:00 2 0.6 3.4 0.4 1.7 0.6 3 0.4 1.4 0.8 3 0.4 330 17 347 255 11 0 11.1 10.6 10/06/2005 15:50:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.6 0.4 1.9 0.4 346 14 4 255 11.1 0 11.1 10.9 10/06/2005 16:00:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 318 30 339 255 10.7 0 11.1 10.6 10/06/2005 16:10:00 1.1 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 319 12 288 255 10.7 0.1 10.9 10.6 10/06/2005 16:20:00 1.8 0.5 2.6 0.7 1.6 0.5 2.6 0.4 1.3 0.6 2.6 0.4 329 9 341 255 10.4 0 10.6 10.3 10/06/2005 16:30:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1 0.5 1.9 0.4 303 9 294 255 10.4 0.1 10.6 10.1 10/06/2005 16:40:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 301 4 306 255 10 0 10.3 9.8 10/06/2005 16:50:00 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 276 23 252 255 9.4 0.1 9.8 9 10/06/2005 17:00:00 1.1 0.5 2.3 0.4 1.2 0.5 1.9 0.4 0.8 0.4 1.9 0.4 248 15 253 255 9.4 0 9.6 9.3 10/06/2005 17:10:00 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 242 13 253 255 8.9 0 9.3 8.8 10/06/2005 17:20:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 221 3 218 255 8.6 0.1 8.8 8.5 10/06/2005 17:30:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 221 0 221 255 8.1 0.1 8.5 7.8 10/06/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 7.6 0.1 7.8 7.3 10/06/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 7.1 0 7.3 7 10/06/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 6.7 0.2 7.3 6.2 10/06/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 6.2 0 6.2 6.2 10/06/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 6 0.2 6.2 5.7 10/06/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 5.6 0 5.7 5.5 10/06/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 5.1 0.2 5.7 4.8 10/06/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 0 255 255 4.7 0 5 4.5 10/06/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 221 0 255 255 4.1 0.2 4.5 3.8 10/06/2005 19:10:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 98 98 15 255 4 0 4 3.8 10/06/2005 19:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 16 8 15 255 3.9 0 4 3.8 10/06/2005 19:30:00 1.4 0.4 1.9 0.4 1.5 0.4 2.3 0.4 0.6 0.2 1.1 0.4 85 3 86 255 3.8 0 4 3.5 10/06/2005 19:40:00 1.8 0.4 2.6 1.1 1.9 0.3 3 1.1 1 0.4 1.9 0.4 75 6 79 255 3.6 0.1 3.8 3.5 10/06/2005 19:50:00 2.1 0.3 2.6 1.1 2.2 0.3 3 1.5 1 0.4 1.9 0.4 82 6 88 255 3.4 0 3.5 3.3 10/06/2005 20:00:00 2 0.3 2.6 1.1 2.1 0.4 3 1.1 0.9 0.4 1.9 0.4 83 6 83 255 3.3 0 3.5 3 10/06/2005 20:10:00 1.9 0.3 2.6 1.1 2 0.4 2.6 1.1 0.6 0.3 1.5 0.4 74 6 87 255 2.9 0 3.5 2.8 10/06/2005 20:20:00 1.4 0.4 2.3 0.7 1.5 0.3 2.3 0.7 0.4 0.2 1.5 0.4 73 6 69 255 2.9 0 3.3 2.8 10/06/2005 20:30:00 1.6 0.3 2.6 0.7 1.6 0.3 2.6 0.7 0.5 0.2 1.5 0.4 67 7 58 255 2.8 0 3.3 2.8 10/06/2005 20:40:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1 0.4 1.5 0.4 82 10 79 255 2.7 0 3.3 2.6 10/06/2005 20:50:00 1.9 0.3 2.6 1.1 1.8 0.4 2.3 0.7 0.5 0.2 1.1 0.4 107 9 95 255 2.5 0.1 2.8 2.3 10/06/2005 21:00:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 0.5 0.3 1.5 0.4 120 8 112 255 2.3 0 2.8 2.3 10/06/2005 21:10:00 2.3 0.3 3 1.5 2.2 0.3 2.6 1.1 1.2 0.5 2.3 0.4 111 7 102 255 2.3 0 2.8 2.3 10/06/2005 21:20:00 1.9 0.5 3 0.7 1.7 0.5 3 0.4 0.7 0.4 1.5 0.4 114 10 118 255 2.2 0 2.8 2.1 10/06/2005 21:30:00 2 0.4 3 1.1 1.9 0.5 3 0.4 1.1 0.4 2.3 0.4 122 8 118 255 2.2 0 2.6 2.1 10/06/2005 21:40:00 2.2 0.4 3.4 0.7 2 0.5 3 0.7 1.5 0.4 2.6 0.4 129 10 129 255 2.1 0 2.8 1.8 10/06/2005 21:50:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 1.5 0.6 3 0.4 120 15 105 255 2.3 0 2.8 2.3 10/06/2005 22:00:00 2.8 0.6 4.6 1.5 2.8 0.6 4.6 1.5 1.5 0.6 3 0.4 117 15 124 255 2.4 0.1 3.3 2.3 10/06/2005 22:10:00 2.6 0.6 4.6 1.1 2.4 0.6 4.2 0.4 1.2 0.7 2.6 0.4 109 13 118 255 2.6 0.1 3 2.6 10/06/2005 22:20:00 3.5 0.5 4.9 2.3 3.3 0.5 4.6 1.9 2.1 0.6 3.8 0.4 112 10 108 255 2.9 0.1 3.5 2.6 10/06/2005 22:30:00 3.3 0.6 4.6 1.1 3.1 0.7 4.6 1.1 2 0.6 3.8 0.7 120 14 94 255 2.9 0 3.5 2.8 10/06/2005 22:40:00 3.2 0.8 5.3 1.1 3.1 0.7 4.9 1.1 1.9 0.7 3.8 0.4 115 15 112 255 3.4 0.2 4.3 3 10/06/2005 22:50:00 3.4 0.6 5.3 1.9 3.2 0.7 4.9 1.5 2.1 0.7 3.4 0.4 111 13 117 255 3.8 0 4 3.5 10/06/2005 23:00:00 3.7 0.6 5.3 2.3 3.6 0.6 4.9 2.3 2.6 0.6 4.6 1.1 105 10 78 255 4 0 4.3 3.8 10/06/2005 23:10:00 3.2 0.8 5.3 1.1 3.1 0.8 4.9 0.7 2 0.9 3.8 0.4 105 17 135 255 4.1 0 4.5 4 10/06/2005 23:20:00 3.5 0.5 5.3 1.9 3.3 0.6 5.3 1.9 2 0.6 4.2 0.7 106 12 115 255 4.1 0 4.3 3.8 10/06/2005 23:30:00 3.3 0.6 5.3 1.9 3.2 0.6 4.6 1.5 2 0.7 3.8 0.4 103 13 86 255 4 0 4.3 3.8 10/06/2005 23:40:00 3.5 0.5 4.9 2.3 3.4 0.6 4.9 1.9 2.4 0.6 4.2 0.7 96 10 95 255 3.8 0 4 3.8 10/06/2005 23:50:00 4.7 0.8 6.8 2.6 4.5 0.8 6.8 1.9 3.5 0.8 5.3 1.5 106 13 127 255 4.7 0.4 5.2 4 10/07/2005 00:00:00 4.7 1 7.2 1.9 4.6 0.9 6.5 2.6 3.6 0.9 5.7 1.5 108 13 130 255 5.5 0.1 5.7 5.2 10/07/2005 00:10:00 4.4 0.9 6.5 1.9 4.2 0.9 6.1 1.5 3.1 1 5.7 1.1 114 14 102 255 5.4 0.1 5.7 5.2 10/07/2005 00:20:00 4.1 0.8 6.1 1.9 3.9 0.8 5.7 1.9 2.9 0.9 5.3 1.1 114 15 126 255 5.3 0 5.5 5 10/07/2005 00:30:00 4 0.7 5.7 1.9 3.7 0.7 5.3 1.9 2.9 0.8 4.9 0.7 107 11 119 255 5.2 0 5.5 5 10/07/2005 00:40:00 4.1 0.7 5.7 1.9 3.9 0.7 5.7 1.9 2.8 0.8 4.6 0.7 108 11 88 255 5.2 0 5.2 5 10/07/2005 00:50:00 4.4 1 6.5 1.9 4.2 1 6.5 1.5 3.2 1 5.7 0.7 102 13 115 255 5.1 0 5.5 5 10/07/2005 01:00:00 4.3 0.8 6.1 2.3 4 0.8 6.1 1.9 3.2 0.8 5.3 1.5 95 13 87 255 5.4 0 5.7 5.2 10/07/2005 01:10:00 4.3 0.7 6.1 2.6 4 0.8 6.1 1.9 3.2 0.9 5.3 1.1 108 11 105 255 5.4 0 5.7 5.2 10/07/2005 01:20:00 3.7 0.9 6.1 1.1 3.4 1 6.1 0.4 2.6 0.9 5.3 0.4 111 15 106 255 5.4 0 5.5 5.5 10/07/2005 01:30:00 3.9 0.6 5.3 2.3 3.7 0.7 5.3 1.5 3 0.7 4.6 1.1 109 12 110 255 5.4 0 5.5 5.5 10/07/2005 01:40:00 3.9 0.8 5.7 1.9 3.7 0.8 5.7 1.5 2.9 0.9 4.9 1.1 112 13 127 255 5.5 0 5.7 5.5 10/07/2005 01:50:00 4.2 0.8 6.1 1.9 4.1 0.8 5.7 1.9 3.2 0.9 5.3 1.1 110 12 118 255 5.6 0 6 5.5 10/07/2005 02:00:00 3.8 1 6.1 1.9 3.6 1 6.1 1.5 2.7 1.1 5.3 0.4 107 14 94 255 5.7 0 6.2 5.7 10/07/2005 02:10:00 3.1 0.8 4.6 0.7 2.8 0.9 4.6 0.4 2.2 0.8 3.8 0.4 98 14 81 255 5.6 0 5.7 5.2 10/07/2005 02:20:00 3.4 0.6 5.3 1.9 3.2 0.6 4.9 1.5 2.4 0.7 4.2 0.4 100 15 109 255 5.2 0 5.7 5 10/07/2005 02:30:00 3.5 0.7 5.3 1.9 3.3 0.8 5.3 1.5 2.4 0.8 4.6 0.4 102 14 74 255 5.1 0 5.7 5 10/07/2005 02:40:00 4.1 0.7 6.1 2.3 3.8 0.8 5.7 1.9 2.8 0.8 4.9 1.1 105 16 91 255 5.1 0 5.5 5 10/07/2005 02:50:00 3.3 0.6 4.9 1.5 3.1 0.7 4.6 1.5 2.1 0.7 3.4 0.4 102 15 108 255 4.8 0.1 5.5 4.8 10/07/2005 03:00:00 3.5 0.7 5.3 1.9 3.3 0.7 4.9 1.1 2.1 0.8 4.2 0.4 109 13 123 255 4.8 0 5.2 4.8 10/07/2005 03:10:00 3 0.8 4.9 0.4 2.7 0.8 4.6 0.4 2 0.8 3.8 0.4 103 17 106 255 4.6 0 5 4.5 10/07/2005 03:20:00 3.1 0.8 5.3 1.5 2.8 0.8 5.3 1.1 1.9 0.8 4.2 0.4 103 15 124 255 4.2 0.1 4.5 4 10/07/2005 03:30:00 4.2 0.9 6.5 1.5 3.9 1 6.5 1.1 3.1 0.9 5.3 1.1 110 13 113 255 4.4 0.2 4.8 4 10/07/2005 03:40:00 4.6 0.8 6.8 2.6 4.4 0.9 6.5 1.9 3.3 0.8 5.3 1.5 111 13 105 255 4.8 0 4.8 4.8 10/07/2005 03:50:00 4.6 0.7 6.1 2.6 4.3 0.7 6.1 2.6 3.5 0.6 5.3 1.9 105 10 121 255 4.7 0 4.8 4.5 10/07/2005 04:00:00 4.4 0.8 6.1 1.9 4.2 0.8 6.1 1.1 3.3 0.8 5.7 1.1 107 13 109 255 4.8 0 4.8 4.8 10/07/2005 04:10:00 4.6 0.8 6.8 2.3 4.3 0.8 6.8 2.3 3.3 0.9 5.7 0.7 114 13 139 255 4.8 0 5 4.8 10/07/2005 04:20:00 4.7 0.9 6.8 2.3 4.6 0.9 7.2 1.5 3.7 1 6.8 0.7 104 13 109 255 4.8 0 5 4.8 10/07/2005 04:30:00 5 1.1 7.2 2.3 4.8 1.1 7.2 1.9 3.9 1.1 7.2 1.5 99 15 109 255 4.9 0 5 4.8 10/07/2005 04:40:00 5.1 1 6.8 2.6 5 0.9 6.8 2.3 4 1 6.1 1.9 101 12 97 255 4.9 0 5 4.8 10/07/2005 04:50:00 5 0.9 6.8 2.6 4.9 0.9 6.8 2.6 3.9 1 6.8 1.5 109 12 104 255 4.9 0 5 4.8 10/07/2005 05:00:00 4.9 0.9 6.8 1.9 4.8 0.9 6.8 2.3 3.8 1 6.1 1.1 106 13 112 255 5.1 0 5 5 10/07/2005 05:10:00 5.2 0.8 6.8 2.6 5 0.8 6.5 3.4 3.9 1 6.5 1.5 105 12 109 255 5.1 0 5 5 10/07/2005 05:20:00 4.6 0.8 6.5 3 4.4 0.8 6.5 2.6 3.4 0.8 5.3 1.5 101 12 108 255 5 0 5 5 10/07/2005 05:30:00 4.9 0.8 7.2 3.4 4.7 0.8 6.8 2.6 3.7 1 6.5 1.5 105 11 109 255 5.1 0 5 5 10/07/2005 05:40:00 4.7 0.9 7.2 1.9 4.6 0.9 7.2 1.9 3.5 1 6.1 1.1 101 13 98 255 5.1 0 5 5 10/07/2005 05:50:00 4.9 0.9 7.2 2.3 4.8 0.9 7.2 2.3 3.8 0.9 6.5 1.9 97 13 99 255 5.1 0 5 5 10/07/2005 06:00:00 5.6 0.9 7.6 3.4 5.4 0.9 8.4 3.4 4.3 0.9 6.8 1.9 99 13 101 255 5.2 0 5.5 5 10/07/2005 06:10:00 5.3 1 7.6 2.6 5.2 1 8 2.3 4.2 0.9 6.1 1.5 101 12 98 255 5.2 0 5.5 5 10/07/2005 06:20:00 4.9 0.9 6.8 2.6 4.7 1 6.8 1.9 3.8 1 6.8 1.5 106 13 106 255 5.2 0 5.5 5 10/07/2005 06:30:00 3.9 0.9 6.5 1.5 3.8 0.9 6.5 1.1 2.8 0.9 5.3 0.7 108 14 115 255 5.1 0 5.2 5 10/07/2005 06:40:00 3.3 0.8 6.1 1.9 3.1 0.8 5.7 1.5 2.5 0.7 4.6 0.7 101 13 94 255 5.1 0 5.2 5 10/07/2005 06:50:00 2.2 0.6 3.4 0.4 2 0.7 3.4 0.4 1.5 0.6 2.6 0.4 83 13 70 255 4.7 0.1 5 4.5 10/07/2005 07:00:00 1.5 0.9 3.4 0.4 1.2 0.8 3.4 0.4 0.8 0.6 2.6 0.4 69 18 95 255 4.1 0.3 4.8 3.5 10/07/2005 07:10:00 1.6 0.5 3 0.4 1.3 0.5 3 0.4 0.9 0.4 1.9 0.4 74 12 97 255 2.9 0.3 3.5 2.6 10/07/2005 07:20:00 1.5 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 51 16 74 255 2.3 0 2.6 1.8 10/07/2005 07:30:00 1.5 0.6 2.6 0.4 1.1 0.5 2.6 0.4 0.4 0.1 1.1 0.4 38 10 46 255 1.8 0 2.3 1.4 10/07/2005 07:40:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 49 4 49 255 1.4 0.1 1.8 1.4 10/07/2005 07:50:00 2 0.6 3.4 0.4 1.6 0.7 3.4 0.4 0.8 0.5 2.6 0.4 68 19 80 255 1.2 0 1.6 1.1 10/07/2005 08:00:00 3.1 0.7 5.7 1.5 2.8 0.8 5.3 1.1 1.9 0.7 4.6 0.4 89 11 96 255 1.7 0.3 2.3 1.4 10/07/2005 08:10:00 3.7 0.8 5.3 1.5 3.4 0.8 5.3 0.7 2.6 0.8 4.6 0.4 89 13 88 255 3.1 0.4 3.8 2.3 10/07/2005 08:20:00 2.6 0.9 4.9 0.4 2.3 1 4.9 0.4 1.7 0.9 3.8 0.4 82 15 68 255 4.1 0.2 4.5 3.5 10/07/2005 08:30:00 2.3 0.9 4.6 0.4 2 1 4.2 0.4 1.4 0.8 3.4 0.4 70 21 89 255 4.3 0 4.5 4.3 10/07/2005 08:40:00 3 0.8 4.9 1.1 2.8 0.8 4.6 0.7 2.1 0.8 4.2 0.4 89 13 100 255 4.9 0.2 5.5 4.5 10/07/2005 08:50:00 2.6 0.7 4.9 1.1 2.4 0.8 4.9 0.4 1.9 0.8 4.2 0.4 74 24 75 255 5.9 0.1 6.2 5.5 10/07/2005 09:00:00 1.7 0.5 3.4 0.7 1.3 0.6 3.4 0.4 1 0.6 3.4 0.4 24 12 32 255 6.1 0 6.2 5.7 10/07/2005 09:10:00 1.2 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 66 26 95 255 6.9 0.3 7.3 6.2 10/07/2005 09:20:00 1.8 0.7 3.4 0.4 1.5 0.7 3 0.4 1.2 0.6 2.6 0.4 77 13 71 255 7.5 0.2 7.8 7.3 10/07/2005 09:30:00 2.1 0.6 3.4 0.7 1.8 0.6 3.8 0.7 1.7 0.6 3 0.4 78 12 71 255 7.8 0 8 7.8 10/07/2005 09:40:00 2 0.7 3.4 0.4 1.7 0.8 3 0.4 1.5 0.8 3 0.4 70 18 64 255 8.3 0.2 8.8 7.8 10/07/2005 09:50:00 1.8 0.5 3.4 0.4 1.5 0.5 3 0.4 1.1 0.6 2.6 0.4 54 17 40 255 9.3 0.2 9.6 8.8 10/07/2005 10:00:00 2.2 0.5 3.4 0.7 1.8 0.5 3 0.4 1.7 0.5 2.6 0.4 42 12 50 255 9 0 9.3 9 10/07/2005 10:10:00 1.9 0.5 3 0.7 1.5 0.5 3 0.4 1.3 0.5 2.3 0.4 39 21 33 255 9.6 0.2 10.1 9.3 10/07/2005 10:20:00 2.2 0.4 3.8 1.1 1.9 0.5 3 0.7 1.7 0.5 3 0.4 31 12 24 255 10.3 0.1 10.6 10.1 10/07/2005 10:30:00 2 0.4 3 0.7 1.7 0.5 3 0.4 1.4 0.5 2.6 0.4 32 17 52 255 10.4 0 10.6 10.3 10/07/2005 10:40:00 1.7 0.5 2.6 0.4 1.5 0.5 2.3 0.4 1.2 0.5 2.3 0.4 15 12 345 255 10.2 0 10.6 9.8 10/07/2005 10:50:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.6 0.3 1.9 0.4 357 15 350 255 10.1 0 10.3 9.8 10/07/2005 11:00:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0 14 0 255 10.5 0.1 10.9 10.3 10/07/2005 11:10:00 2.2 0.3 3 1.5 1.9 0.4 3 0.7 1.5 0.5 3 0.4 348 11 347 255 10.8 0 11.1 10.6 10/07/2005 11:20:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.5 2.3 0.4 359 14 0 255 10.7 0.1 11.1 10.3 10/07/2005 11:30:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 340 17 319 255 11.1 0 11.1 10.9 10/07/2005 11:40:00 1.5 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 352 16 352 255 11.3 0.1 11.7 10.9 10/07/2005 11:50:00 1.7 0.6 3.8 0.4 1.4 0.7 3.4 0.4 1 0.6 3 0.4 331 35 2 255 11.5 0 11.7 11.4 10/07/2005 12:00:00 2.2 0.6 3.8 0.7 1.8 0.6 3.4 0.4 1.3 0.7 3.4 0.4 353 17 343 255 11.7 0.2 12.2 11.4 10/07/2005 12:10:00 1.5 0.6 3 0.4 1.1 0.6 3 0.4 0.8 0.5 2.3 0.4 308 28 339 255 12.3 0 12.5 12.2 10/07/2005 12:20:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.3 0.5 2.3 0.4 355 29 16 255 12.7 0 12.7 12.5 10/07/2005 12:30:00 1.7 0.5 3 0.4 1.5 0.6 3 0.4 1.2 0.6 2.3 0.4 337 21 359 255 12.5 0.1 12.7 12.5 10/07/2005 12:40:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1 0.6 2.6 0.4 350 16 342 255 12.1 0 12.5 11.9 10/07/2005 12:50:00 1.6 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.3 0.7 3 0.4 350 24 314 255 11.9 0 12.2 11.9 10/07/2005 13:00:00 1.4 0.6 2.6 0.4 1.6 0.6 3 0.4 1 0.7 3 0.4 355 15 10 255 12.1 0.1 12.5 11.9 10/07/2005 13:10:00 2.2 0.7 4.2 0.4 2.1 0.7 4.2 0.4 1.8 0.7 3.8 0.4 307 13 311 255 12.7 0.1 13 12.5 10/07/2005 13:20:00 0.9 0.7 3.4 0.4 0.9 0.7 3.4 0.4 0.7 0.6 2.6 0.4 263 35 254 255 13.5 0.1 13.8 13 10/07/2005 13:30:00 1.2 0.8 3 0.4 1.3 0.8 3 0.4 0.9 0.7 2.6 0.4 347 38 51 255 13.9 0 14.4 13.5 10/07/2005 13:40:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.4 0.7 3 0.4 19 22 20 255 14.1 0.1 14.6 13.8 10/07/2005 13:50:00 2 0.7 3.8 0.4 2.2 0.6 4.2 0.4 1.5 0.6 3 0.4 356 26 8 255 14.3 0.1 15.2 14.1 10/07/2005 14:00:00 2.9 1 4.9 0.4 3 1 4.9 0.7 2.4 1 4.6 0.4 26 32 31 255 14.4 0.2 15.2 14.1 10/07/2005 14:10:00 4.8 0.7 6.8 2.6 4.9 0.7 6.5 2.6 4.3 0.9 6.5 1.9 23 13 32 255 14.2 0.2 14.9 13.8 10/07/2005 14:20:00 4.2 0.8 6.8 1.9 4.2 0.8 6.5 1.9 3.7 0.9 6.1 1.1 30 17 27 255 13.9 0 14.6 13.8 10/07/2005 14:30:00 5.2 0.8 7.2 3.4 5.3 0.8 7.6 3.4 4.3 0.9 6.5 1.5 10 14 4 255 14.3 0.2 14.9 13.8 10/07/2005 14:40:00 5.3 1 7.2 2.3 5.4 1 7.2 2.3 4.2 1.3 7.2 1.5 8 12 13 255 14.8 0 15.2 14.6 10/07/2005 14:50:00 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3.4 4.3 0.7 6.1 2.3 17 8 22 255 14.5 0.3 15.2 13.8 10/07/2005 15:00:00 3.9 0.5 5.7 2.6 3.9 0.6 6.1 2.6 3.3 0.7 4.9 1.1 28 13 24 255 12.9 0.4 13.8 12.2 10/07/2005 15:10:00 3.4 0.7 5.7 1.1 3.5 0.7 5.7 1.5 2.8 0.8 4.9 0.7 47 15 34 255 12.3 0.2 12.7 11.9 10/07/2005 15:20:00 4 0.8 5.7 2.3 4.1 0.8 6.1 2.3 3.4 1 5.7 1.1 44 12 27 255 11.6 0 11.9 11.4 10/07/2005 15:30:00 3.2 0.5 4.2 1.5 3.2 0.5 4.2 1.9 2.4 0.7 3.8 0.4 48 12 52 255 11.3 0.1 11.9 11.1 10/07/2005 15:40:00 3.3 0.8 5.3 1.1 3.4 0.8 5.3 1.5 2.6 0.8 4.6 0.7 48 14 38 255 11.8 0 11.9 11.7 10/07/2005 15:50:00 3 0.5 4.2 1.1 2.9 0.6 4.2 1.1 2.5 0.7 3.8 0.4 33 17 45 255 11.9 0 11.9 11.9 10/07/2005 16:00:00 3.5 0.8 5.7 1.9 3.4 0.9 6.1 1.5 2.8 0.9 4.9 1.1 24 13 9 255 12.1 0 12.2 11.9 10/07/2005 16:10:00 3.4 0.6 4.6 1.9 3.4 0.6 4.9 1.5 2.6 0.8 4.9 0.4 14 10 18 255 11.9 0.1 12.2 11.7 10/07/2005 16:20:00 3.7 1.5 6.8 1.1 3.7 1.5 6.8 0.7 3 1.5 6.8 0.7 34 20 42 255 11.7 0 11.9 11.7 10/07/2005 16:30:00 4.2 0.7 6.1 2.6 4.2 0.7 6.1 2.6 3.5 0.8 5.7 1.9 37 10 40 255 11.7 0 11.9 11.7 10/07/2005 16:40:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.9 2.2 0.5 3.4 0.7 27 13 44 255 11.3 0.1 11.7 11.1 10/07/2005 16:50:00 2.4 0.5 3.4 1.1 2.4 0.5 3.4 1.1 1.8 0.7 3 0.4 24 9 9 255 10.6 0.2 11.1 10.3 10/07/2005 17:00:00 2.4 0.6 3.8 1.5 2.5 0.6 3.8 1.5 1.8 0.8 3.4 0.4 26 6 26 255 9.8 0.2 10.3 9.6 10/07/2005 17:10:00 1.8 0.6 3 0.4 1.9 0.6 3 0.4 1.2 0.7 3 0.4 25 13 30 255 9 0.2 9.6 8.5 10/07/2005 17:20:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 8 9 12 255 8.3 0.2 8.8 8 10/07/2005 17:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 343 0 343 255 8 0 8.3 7.8 10/07/2005 17:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 243 17 241 255 7.7 0.1 8 7.3 10/07/2005 17:50:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 248 36 60 255 7.1 0.1 7.3 6.7 10/07/2005 18:00:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0.1 0.7 0.4 44 12 34 255 6.6 0 7 6.2 10/07/2005 18:10:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 13 15 12 255 6 0.2 6.2 5.7 10/07/2005 18:20:00 1.6 0.4 2.3 0.7 1.2 0.5 2.3 0.4 0.4 0.2 1.1 0.4 354 7 357 255 5.4 0.1 5.7 5 10/07/2005 18:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 309 10 323 255 5.1 0 5.2 5 10/07/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 4.9 0 5 5 10/07/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 4.8 0.2 5 4.5 10/07/2005 19:00:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 226 94 116 255 4.3 0 4.5 4 10/07/2005 19:10:00 1.6 0.2 2.3 0.7 1.5 0.2 2.3 0.7 1.1 0.3 1.9 0.4 133 7 124 255 4 0 4.3 4 10/07/2005 19:20:00 1.7 0.3 2.3 0.7 1.6 0.3 2.3 0.7 0.7 0.3 1.5 0.4 113 7 115 255 3.8 0 4.3 3.5 10/07/2005 19:30:00 2.5 0.3 3 1.9 2.4 0.3 3 1.5 1.4 0.5 2.3 0.4 99 4 94 255 3.6 0 4 3.5 10/07/2005 19:40:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2 0.5 3.4 0.7 93 4 89 255 3.4 0 3.8 3.3 10/07/2005 19:50:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.3 2.6 0.4 3.4 1.5 90 5 93 255 3.2 0 3.5 3 10/07/2005 20:00:00 4 0.5 4.9 3 4 0.5 4.9 3 3.2 0.5 4.6 1.9 77 13 79 255 3.3 0.2 4 2.8 10/07/2005 20:10:00 3.7 0.4 4.6 2.3 3.7 0.5 4.9 2.3 2.9 0.5 4.2 1.9 65 8 59 255 3.7 0 4.3 3.5 10/07/2005 20:20:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.6 2.8 0.5 4.6 1.9 64 9 73 255 3.7 0 4.3 3.5 10/07/2005 20:30:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 2.6 0.5 3.8 1.5 63 12 65 255 4 0.1 4.5 3.8 10/07/2005 20:40:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 2.8 0.4 3.8 1.9 76 6 79 255 4 0 4.5 4 10/07/2005 20:50:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.3 2.9 0.6 4.6 1.5 79 9 72 255 4 0 4.3 3.8 10/07/2005 21:00:00 2.8 0.6 4.6 1.5 2.7 0.6 4.6 1.1 2.1 0.5 3.4 1.1 67 17 93 255 4.2 0.2 4.8 3.8 10/07/2005 21:10:00 2.2 0.6 3.8 0.7 2.2 0.7 3.8 0.4 1.1 0.7 3.4 0.4 64 13 66 255 3.2 0.4 4.3 2.8 10/07/2005 21:20:00 2.3 0.8 3.4 0.4 2.2 0.9 3.8 0.4 1.5 0.8 3 0.4 58 20 37 255 2.9 0 3.3 2.8 10/07/2005 21:30:00 2.8 0.6 4.6 1.1 2.8 0.6 4.6 1.1 1.8 0.7 3.8 0.4 80 21 76 255 2.6 0 3.3 2.3 10/07/2005 21:40:00 2.3 0.7 3.8 0.7 2.1 0.8 3.8 0.4 1.4 0.8 3 0.4 63 11 95 255 2.5 0 2.6 2.3 10/07/2005 21:50:00 2.4 0.4 3.4 1.5 2.3 0.5 3.8 1.5 1.5 0.4 2.6 0.7 68 8 69 255 2.5 0 2.8 2.3 10/07/2005 22:00:00 3.4 0.7 5.7 1.9 3.4 0.7 5.3 1.9 2.4 0.7 4.6 0.7 90 13 97 255 2.5 0 2.8 2.3 10/07/2005 22:10:00 4.2 0.7 6.1 2.3 4.2 0.7 6.1 2.3 3.1 0.8 5.3 1.1 88 11 89 255 3.3 0.4 4.5 2.8 10/07/2005 22:20:00 4.5 0.7 6.5 2.6 4.5 0.7 6.5 2.6 3.5 0.7 5.3 1.9 95 9 98 255 4.3 0.2 5 4 10/07/2005 22:30:00 4.9 0.7 6.5 3 4.9 0.7 6.8 2.6 3.9 0.8 6.1 1.9 100 8 99 255 5.3 0.2 6 5 10/07/2005 22:40:00 4.7 0.7 6.1 2.6 4.6 0.7 6.5 2.3 3.5 0.9 5.3 1.1 103 11 104 255 5.8 0 6 5.7 10/07/2005 22:50:00 4.5 0.6 6.1 3 4.5 0.6 5.7 3 3.5 0.6 5.3 1.9 98 9 89 255 5.8 0 6 5.7 10/07/2005 23:00:00 4.7 0.7 6.1 2.6 4.5 0.7 6.1 2.6 3.4 0.9 4.9 1.1 97 10 104 255 5.7 0 5.7 5.7 10/07/2005 23:10:00 5 0.7 6.5 3.4 5 0.6 6.8 3.4 4.1 0.8 6.1 1.9 103 9 105 255 5.7 0 6 5.7 10/07/2005 23:20:00 4.8 0.7 6.5 3 4.8 0.7 6.5 2.3 3.7 0.8 5.3 1.5 106 10 101 255 5.8 0 6 5.7 10/07/2005 23:30:00 4.9 0.6 6.5 3 4.9 0.6 6.8 3 3.9 0.8 5.7 1.9 105 12 94 255 5.8 0 6 5.7 10/07/2005 23:40:00 4.6 1 6.5 2.3 4.5 0.9 6.5 2.3 3.5 1 6.1 1.1 107 13 100 255 5.9 0 6 5.7 10/07/2005 23:50:00 4.9 0.8 6.8 2.6 4.8 0.8 6.8 2.6 3.9 0.9 6.1 1.9 110 12 113 255 5.7 0.1 6 5.7 10/08/2005 00:00:00 5.4 1 7.6 2.6 5.3 1 7.6 2.6 4.2 1 6.5 1.9 112 13 112 255 5.9 0 6 5.7 10/08/2005 00:10:00 5.1 1 7.2 2.6 5 1 7.6 2.6 3.9 1 6.5 1.5 113 12 103 255 5.9 0.1 6 5.7 10/08/2005 00:20:00 5.9 0.8 7.6 3.4 5.8 0.7 7.6 3 4.7 0.9 6.8 2.6 104 10 109 255 6 0 6.2 5.7 10/08/2005 00:30:00 5.3 0.8 8 2.6 5.2 0.8 7.2 2.6 4.3 0.8 6.8 1.9 103 9 94 255 6.1 0 6.2 6 10/08/2005 00:40:00 5.2 0.8 7.2 3.4 5.2 0.7 6.8 3.4 4.1 0.9 6.5 1.9 104 10 108 255 6 0 6 5.7 10/08/2005 00:50:00 5.2 0.8 7.2 2.6 5.2 0.9 6.8 2.6 4 0.9 6.1 0.7 104 10 113 255 5.8 0 6 5.7 10/08/2005 01:00:00 5.2 1 7.2 2.6 5.1 0.9 7.2 2.3 4.1 1 6.5 1.5 107 11 88 255 5.7 0 5.7 5.7 10/08/2005 01:10:00 4.5 0.5 5.7 3 4.5 0.5 5.7 3.4 3.6 0.6 5.3 1.5 101 10 102 255 5.6 0 5.7 5.5 10/08/2005 01:20:00 3.6 0.8 5.3 1.5 3.6 0.7 5.3 1.5 2.8 0.8 4.6 0.4 112 14 83 255 5.4 0 5.5 5.2 10/08/2005 01:30:00 4.2 0.8 6.5 1.9 4.2 0.8 6.5 2.3 3.2 0.9 5.3 0.4 108 15 118 255 5.1 0 5.5 5 10/08/2005 01:40:00 4.3 0.8 6.8 1.9 4.3 0.8 6.5 2.3 3.4 1 5.7 1.1 104 12 94 255 5.2 0 5.5 5 10/08/2005 01:50:00 4.9 1.2 7.6 1.1 5 1.1 7.6 1.5 3.9 1.1 6.5 1.5 106 14 113 255 5.4 0 5.5 5.2 10/08/2005 02:00:00 5 1 7.6 2.3 5 1 7.2 2.6 3.9 0.9 6.1 1.1 108 12 119 255 5.3 0 5.5 5.2 10/08/2005 02:10:00 4.8 1 7.2 2.3 4.8 1 7.2 2.3 3.7 1 6.5 1.5 106 13 93 255 5.2 0 5.5 5 10/08/2005 02:20:00 4.8 0.8 6.8 2.6 4.8 0.7 6.5 2.6 3.9 0.8 5.7 1.9 106 14 97 255 5.2 0 5.5 5 10/08/2005 02:30:00 5.1 1.2 7.6 2.6 5.1 1.2 7.6 2.3 3.9 1.2 7.2 0.7 109 17 106 255 5.3 0 5.5 5.2 10/08/2005 02:40:00 5.4 1 8 2.6 5.4 1 8 3 4.3 1 7.2 1.5 108 13 81 255 5.2 0 5.5 5 10/08/2005 02:50:00 5.2 1 7.6 2.6 5.1 1 7.2 2.6 4.1 1 6.5 1.5 109 14 116 255 5.1 0 5.2 5 10/08/2005 03:00:00 5.3 1.1 8.4 2.3 5.3 1.1 8 2.3 4.2 1.1 7.6 1.9 110 15 112 255 5 0 5 4.8 10/08/2005 03:10:00 6.1 1.2 8.8 2.3 6.1 1.1 8.8 2.6 4.9 1.2 8 1.9 109 12 90 255 5 0 5 4.8 10/08/2005 03:20:00 6.1 1.2 9.1 2.6 6.1 1.2 9.1 3.8 4.8 1.1 7.6 1.5 109 13 96 255 5.1 0 5 5 10/08/2005 03:30:00 5.8 1.2 9.1 2.3 5.8 1.2 8.8 2.3 4.7 1.1 7.6 1.9 106 15 110 255 5.1 0 5 5 10/08/2005 03:40:00 6.2 1.2 9.1 3 6.2 1.2 8.8 3 5.1 1.2 8 1.9 110 13 117 255 5.1 0 5 5 10/08/2005 03:50:00 5.8 1.2 8 2.6 5.7 1.1 8 2.3 4.7 1.1 7.2 1.5 110 14 115 255 5.1 0 5 5 10/08/2005 04:00:00 5.9 1.1 8.8 3.4 5.8 1 8.4 3.8 4.7 1.1 7.6 1.9 108 15 118 255 4.9 0 5 4.8 10/08/2005 04:10:00 6.1 1 8.8 3 6.1 0.9 8.4 3 5 1 7.6 2.6 102 12 84 255 4.7 0.1 5 4.5 10/08/2005 04:20:00 6 1 8.8 3.4 5.9 1 8.4 3 4.8 1.1 7.2 2.3 104 15 105 255 4.6 0 4.8 4.5 10/08/2005 04:30:00 6.6 1.2 9.1 3.8 6.5 1.2 9.1 3.8 5.4 1.3 8.8 2.3 110 12 110 255 4.6 0 4.8 4.5 10/08/2005 04:40:00 5.8 1 8.8 3.4 5.8 1 8.4 3.4 4.8 1.2 7.6 1.9 108 13 87 255 4.6 0 4.8 4.5 10/08/2005 04:50:00 6.4 1.1 9.1 3.4 6.4 1 9.1 3.4 5 1.2 8.8 1.9 106 13 100 255 4.4 0 4.5 4.3 10/08/2005 05:00:00 6.5 1 8.8 3.4 6.5 0.9 8.8 3.8 5.2 1.2 8 2.6 113 12 118 255 4.4 0 4.5 4.3 10/08/2005 05:10:00 6.4 1.3 9.5 2.6 6.4 1.2 9.1 2.6 5.2 1.2 8.4 2.6 113 15 113 255 4.3 0 4.5 4.3 10/08/2005 05:20:00 6.1 1.2 8.8 3 6.1 1.1 8.8 2.3 4.9 1.1 7.6 1.9 114 12 111 255 4.3 0 4.5 4.3 10/08/2005 05:30:00 5.4 1.1 8.8 2.6 5.4 1.1 8.4 2.3 4.4 1 7.2 2.3 107 13 97 255 4.3 0 4.5 4.3 10/08/2005 05:40:00 6.3 1.2 9.5 3 6.3 1.1 10.3 3.4 5.1 1 8.4 2.6 108 13 109 255 4.1 0 4.3 4 10/08/2005 05:50:00 6 1.1 8.8 2.6 6 1.1 8.4 3 5.1 1.2 8 2.6 109 11 113 255 4 0 4.3 4 10/08/2005 06:00:00 6.7 1.2 9.1 2.6 6.7 1.1 9.1 3 5.5 1.1 8.4 2.6 110 12 115 255 4.1 0 4.3 4 10/08/2005 06:10:00 6.2 1.1 8.8 3 6.2 1.1 8.8 3.4 5.2 1.1 8 2.3 109 12 86 255 4.1 0 4.3 4 10/08/2005 06:20:00 5.8 1.1 8 2.6 5.8 1 8 2.6 4.9 1 7.6 1.9 109 13 106 255 4.1 0 4.3 4 10/08/2005 06:30:00 5.3 1.1 8 2.3 5.3 1 8 2.6 4.5 1.1 6.8 1.9 104 14 93 255 4.1 0 4.3 4 10/08/2005 06:40:00 5.9 1.1 8.4 3 5.9 1 8.8 3 4.9 1 7.6 2.6 109 12 123 255 4.2 0 4.3 4.3 10/08/2005 06:50:00 6.8 1.1 9.5 3.8 6.6 1.1 9.1 3.4 5.5 1.1 8.4 3 113 13 118 255 4.3 0 4.5 4.3 10/08/2005 07:00:00 6.3 1.1 9.5 3.4 6.3 1.1 9.1 3.4 5.4 1.1 9.1 2.6 114 12 119 255 4.3 0 4.5 4.3 10/08/2005 07:10:00 6.6 1.2 9.5 3.4 6.6 1.1 8.8 3.8 5.5 1.2 8.4 3 112 13 93 255 4.3 0 4.5 4.3 10/08/2005 07:20:00 6.1 1.2 9.1 3 6.1 1.2 9.1 3 4.8 1.2 8 2.3 113 14 119 255 4.4 0 4.5 4.3 10/08/2005 07:30:00 6.3 1.3 9.1 2.6 6.2 1.2 9.5 3 5.2 1.2 8 1.9 113 13 112 255 4.6 0 4.8 4.5 10/08/2005 07:40:00 6.3 1.3 9.1 3 6.3 1.2 9.1 2.3 5.1 1.4 8.4 1.5 110 13 116 255 4.6 0 4.8 4.5 10/08/2005 07:50:00 6.3 1.3 9.5 2.3 6.3 1.2 9.5 1.9 5.4 1.2 8.4 3 112 13 104 255 4.6 0 4.8 4.5 10/08/2005 08:00:00 6.7 1.2 10.7 4.2 6.6 1.2 10.7 3.8 5.7 1.2 8.8 3 108 14 133 255 4.8 0 4.8 4.8 10/08/2005 08:10:00 6.7 1.3 9.9 3 6.5 1.3 9.9 2.6 5.6 1.3 9.1 2.6 110 15 106 255 5 0 5.2 4.8 10/08/2005 08:20:00 6.3 1.4 9.5 3 6.2 1.3 9.1 2.6 5.3 1.3 8.8 1.9 107 15 103 255 5.3 0 5.5 5 10/08/2005 08:30:00 7 1.7 10.7 2.6 6.9 1.7 10.3 3 5.8 1.6 9.9 1.9 106 16 102 255 5.3 0 5.5 5.2 10/08/2005 08:40:00 7 1.7 10.7 1.5 6.9 1.6 10.3 1.9 6 1.4 9.5 1.9 109 13 109 255 5.3 0 5.7 5.2 10/08/2005 08:50:00 7.1 1.3 11.1 3.8 7 1.3 10.7 3.4 6.3 1.3 10.3 3.4 109 14 94 255 5.7 0 5.7 5.5 10/08/2005 09:00:00 6.9 1.4 10.3 3.4 6.8 1.4 10.3 3.4 6 1.3 9.9 2.6 110 12 106 255 5.9 0 6 5.7 10/08/2005 09:10:00 6.3 1.3 9.9 3 6.3 1.3 9.1 3.4 5.3 1.3 8.8 2.3 112 15 118 255 6.3 0.1 6.7 6 10/08/2005 09:20:00 6.4 1.3 9.1 2.6 6.3 1.3 9.1 2.6 5.5 1.3 8.4 2.3 110 13 134 255 6.6 0 6.7 6.5 10/08/2005 09:30:00 6.1 1.3 8.8 2.6 6 1.2 9.1 2.6 5.3 1.3 8.4 1.5 109 13 100 255 6.9 0 7 6.7 10/08/2005 09:40:00 6.6 1.2 9.1 3 6.5 1.2 9.9 3 5.7 1.2 8.8 2.6 114 14 96 255 7 0 7.3 7 10/08/2005 09:50:00 6.7 1.5 9.9 2.6 6.5 1.5 10.3 2.3 5.9 1.2 8.4 2.6 116 13 103 255 7.3 0 7.5 7 10/08/2005 10:00:00 6.1 1.2 9.5 3.4 6 1.2 9.1 3 5.1 1.1 8.4 2.6 112 15 105 255 6.8 0.1 7.3 6.7 10/08/2005 10:10:00 6.4 1.5 9.9 3 6.4 1.4 9.5 2.6 5.4 1.2 8.8 3 114 16 108 255 6.5 0 6.7 6.5 10/08/2005 10:20:00 6.5 1.3 9.5 1.9 6.5 1.2 9.5 2.3 5.4 1.3 8.4 1.5 118 17 95 255 6.6 0 6.7 6.5 10/08/2005 10:30:00 6.1 1.3 9.5 2.3 6.1 1.3 9.1 2.6 5.2 1.3 8.8 2.3 115 15 106 255 6.8 0 7 6.7 10/08/2005 10:40:00 6.4 1.3 9.9 3.4 6.4 1.2 9.9 3.4 5.9 1.1 9.1 3 113 14 97 255 7.2 0 7.3 7 10/08/2005 10:50:00 5.6 1.3 9.5 2.3 5.6 1.3 9.1 2.3 4.9 1.3 8 1.1 110 16 110 255 7.6 0 7.8 7.3 10/08/2005 11:00:00 5.6 1.2 8.8 2.3 5.5 1.2 8.4 2.3 4.9 1 7.2 2.6 107 15 95 255 8 0 8.3 7.8 10/08/2005 11:10:00 6.2 1.5 9.5 1.9 6.1 1.4 9.5 2.3 5.2 1.4 8.8 1.9 107 15 108 255 8.2 0 8.5 8.3 10/08/2005 11:20:00 5.8 1.2 8.8 3 5.7 1.3 9.1 2.6 5 1.2 8.8 2.3 104 14 110 255 8.4 0 8.5 8.3 10/08/2005 11:30:00 6.4 1.2 9.5 3.4 6.4 1.2 9.5 3.4 5.4 1.2 9.1 2.6 105 13 106 255 8.5 0 8.8 8.5 10/08/2005 11:40:00 5.2 1.2 8 2.6 5.2 1.1 8.4 2.6 4.5 1.2 7.6 1.9 97 14 82 255 8.5 0 8.8 8.5 10/08/2005 11:50:00 5.1 1.2 8 2.6 5.1 1.2 7.6 2.6 4.2 1.4 7.6 1.1 103 15 103 255 8.7 0 8.8 8.5 10/08/2005 12:00:00 4.3 1 6.8 1.9 4.2 1 6.8 1.9 3.4 1 7.6 1.1 104 16 122 255 8.9 0 9 8.8 10/08/2005 12:10:00 4.5 1.1 7.6 1.9 4.4 1.1 7.6 1.9 3.9 1 6.5 1.1 103 14 98 255 9 0 9 9 10/08/2005 12:20:00 4.2 1 6.5 0.7 4.1 1 6.5 0.4 3.4 1.1 6.5 0.4 103 14 76 255 9.1 0 9.3 9 10/08/2005 12:30:00 3.8 1 6.1 1.5 3.7 1 6.1 1.5 3.2 0.9 5.7 1.1 98 16 96 255 9 0 9 9 10/08/2005 12:40:00 3.6 1 6.5 1.5 3.5 1 6.1 1.1 3 1 6.5 1.1 84 16 83 255 9.1 0 9.3 9 10/08/2005 12:50:00 4.1 1 7.6 1.5 4.1 1 7.2 1.5 3.4 1 6.1 1.1 82 15 74 255 9.3 0 9.6 9 10/08/2005 13:00:00 4.3 1 6.5 1.9 4.2 1 6.8 1.5 3.4 1 6.1 0.7 94 16 107 255 9.5 0 9.6 9.3 10/08/2005 13:10:00 4.1 1 6.5 1.1 3.9 1 6.5 1.1 3.4 1 5.7 1.1 87 15 77 255 9.6 0 9.8 9.6 10/08/2005 13:20:00 4.4 1.1 7.2 1.5 4.3 1.2 7.6 1.5 3.6 1.1 6.1 1.5 98 17 89 255 9.9 0 10.1 9.8 10/08/2005 13:30:00 5.3 0.8 7.6 2.6 5.1 0.8 7.2 2.6 4.4 1 6.5 1.1 107 14 118 255 9.8 0 10.1 9.8 10/08/2005 13:40:00 4.6 1.1 7.2 1.9 4.5 1.1 6.5 1.5 3.8 1 6.1 0.7 97 18 78 255 10.1 0.1 10.3 9.8 10/08/2005 13:50:00 5 1 7.2 1.9 5 1 7.6 1.9 4.4 1 6.8 1.5 99 14 105 255 10.4 0 10.6 10.3 10/08/2005 14:00:00 4.5 1.1 6.8 1.5 4.4 1.1 6.5 1.5 4 1.1 6.5 0.4 98 16 90 255 11.1 0.2 11.4 10.6 10/08/2005 14:10:00 5 1.1 7.6 1.9 4.8 1 7.2 1.9 4.4 1 8 1.5 96 16 63 255 11.1 0 11.4 10.9 10/08/2005 14:20:00 4.2 0.9 6.8 1.9 4 0.9 6.1 1.1 3.6 1 6.1 1.1 86 13 94 255 10.9 0 11.1 10.6 10/08/2005 14:30:00 4.4 1 6.8 1.5 4.2 1.1 6.5 1.1 3.7 0.9 6.5 1.5 89 13 97 255 10.4 0.1 10.9 10.3 10/08/2005 14:40:00 3.9 1 6.5 1.5 3.7 1.1 6.5 1.1 3.1 1 6.5 1.1 86 16 96 255 10.1 0 10.3 10.1 10/08/2005 14:50:00 3.5 1.1 6.8 1.5 3.4 1.2 7.2 0.7 3 1.1 6.1 0.7 79 19 100 255 10 0 10.1 9.8 10/08/2005 15:00:00 4.1 1.3 7.6 1.1 3.9 1.4 7.6 1.5 3.3 1.5 7.2 0.4 77 19 64 255 10 0 10.1 9.8 10/08/2005 15:10:00 3.6 0.8 6.1 1.9 3.5 0.9 6.1 1.5 3 1 6.8 0.4 91 16 61 255 9.8 0 10.1 9.8 10/08/2005 15:20:00 3.7 1.1 6.5 1.1 3.5 1.1 6.5 0.7 2.9 1.1 5.7 0.7 80 13 77 255 9.7 0 9.8 9.6 10/08/2005 15:30:00 4.2 1 6.8 1.5 4.2 1 6.8 1.5 3.4 1 6.1 0.7 81 17 78 255 9.8 0 9.8 9.6 10/08/2005 15:40:00 4.4 1.2 7.6 1.9 4.3 1.1 7.2 1.5 3.6 1.2 6.8 1.1 90 15 73 255 9.8 0 9.8 9.6 10/08/2005 15:50:00 5 0.9 6.8 2.3 4.9 1 6.8 1.9 4.2 1 6.5 1.5 95 14 96 255 9.5 0 9.6 9.6 10/08/2005 16:00:00 5.3 1.1 8 2.6 5.1 1.1 8.4 2.3 4.4 1.2 6.8 1.5 93 13 102 255 9.5 0 9.6 9.3 10/08/2005 16:10:00 4.9 1.2 7.2 1.9 4.8 1.1 6.8 1.9 4.2 1.3 7.6 1.5 96 16 95 255 9.4 0 9.6 9.3 10/08/2005 16:20:00 4.9 1 7.2 2.6 4.9 0.9 7.2 2.6 4.3 1 7.2 1.9 97 13 112 255 9.4 0 9.6 9.3 10/08/2005 16:30:00 5 1 7.2 2.6 5 1 7.2 2.3 4.3 1.1 6.8 0.4 96 13 92 255 9.5 0 9.6 9.3 10/08/2005 16:40:00 4.3 1.1 6.5 1.5 4.2 1.1 6.5 1.5 3.5 1.1 6.1 0.4 90 16 82 255 9.6 0 9.8 9.6 10/08/2005 16:50:00 3.8 0.8 6.1 1.9 3.5 0.9 6.1 1.5 3.1 0.8 4.9 1.1 88 13 83 255 9.6 0 9.8 9.6 10/08/2005 17:00:00 3.4 0.9 5.7 1.5 3.3 1 5.7 1.5 2.8 1 6.1 0.4 88 13 98 255 9.6 0 9.8 9.6 10/08/2005 17:10:00 3.5 0.8 4.9 1.5 3.4 0.8 4.9 1.5 2.8 0.8 4.6 0.4 94 12 94 255 9.4 0 9.6 9.3 10/08/2005 17:20:00 3.7 0.8 5.7 1.9 3.6 0.8 5.7 1.9 2.8 0.8 4.9 0.4 96 14 82 255 9.1 0.1 9.3 8.8 10/08/2005 17:30:00 3.9 0.8 5.7 1.9 3.8 0.8 5.7 1.1 3.2 0.8 4.9 1.1 100 13 94 255 8.7 0 9 8.5 10/08/2005 17:40:00 4.2 1 7.2 1.5 4.1 1 7.2 1.9 3.3 0.9 5.7 1.1 107 17 127 255 8.5 0 8.8 8.5 10/08/2005 17:50:00 4.7 1.1 6.8 1.1 4.7 1 7.2 1.5 3.7 1.1 6.5 0.4 104 17 95 255 8.4 0 8.5 8.5 10/08/2005 18:00:00 4.4 1.1 8 1.5 4.4 1 7.6 1.5 3.8 1 6.5 1.1 102 13 104 255 8.3 0 8.5 8.3 10/08/2005 18:10:00 5 1 7.6 2.6 5 1 7.2 2.6 4.1 1 6.8 1.5 103 15 106 255 8.3 0 8.5 8.3 10/08/2005 18:20:00 4.7 1 7.2 1.9 4.7 1 6.8 1.9 3.9 1.1 6.5 1.1 105 15 102 255 8.1 0 8.3 8 10/08/2005 18:30:00 5 1 7.6 1.9 4.9 1 7.2 2.6 4.1 1 7.2 1.5 102 12 93 255 8.1 0 8.3 8 10/08/2005 18:40:00 4.9 1.3 8.4 2.3 4.9 1.3 8.4 2.3 3.9 1.2 6.8 1.5 103 15 116 255 8 0 8.3 8 10/08/2005 18:50:00 4.4 1 7.2 2.3 4.4 1 7.2 2.3 3.3 1 6.1 0.7 100 15 85 255 8.1 0 8.3 8 10/08/2005 19:00:00 4.5 0.9 6.5 2.6 4.5 0.9 6.5 2.3 3.7 1 5.7 1.1 97 12 95 255 8 0 8.3 8 10/08/2005 19:10:00 4.6 1 7.2 2.3 4.6 1 6.8 2.3 3.8 1.1 6.8 1.1 109 12 107 255 8 0 8 7.8 10/08/2005 19:20:00 4.6 1 6.8 1.9 4.5 1 6.8 1.5 3.8 1 6.8 1.5 103 12 94 255 7.9 0 8 7.8 10/08/2005 19:30:00 5.1 1.1 7.6 2.6 5 1.1 8 2.6 4.2 1 7.6 1.9 104 12 111 255 8 0 8 7.8 10/08/2005 19:40:00 4.2 1.2 7.2 1.9 4.1 1.2 7.6 1.9 3.3 1.2 6.5 0.7 106 15 106 255 8 0 8 7.8 10/08/2005 19:50:00 5.5 1 7.6 3.4 5.4 0.9 7.6 3 4.6 1 7.2 2.3 107 13 83 255 8 0 8 7.8 10/08/2005 20:00:00 5.3 1 8 2.6 5.2 1 8 2.6 4.2 1 7.2 1.5 105 15 104 255 8 0 8 7.8 10/08/2005 20:10:00 5.2 1 7.6 2.3 5.2 1 8 2.6 4.3 1 7.6 1.9 104 15 113 255 8 0 8 7.8 10/08/2005 20:20:00 4 1 6.5 1.9 3.8 1 6.5 1.1 3.2 1.1 6.5 0.4 105 16 116 255 7.9 0 8 7.8 10/08/2005 20:30:00 3.9 1 6.1 1.5 3.8 1 6.5 1.5 3.2 1 5.7 0.7 96 14 96 255 7.6 0 7.8 7.5 10/08/2005 20:40:00 4.5 1.1 9.1 1.9 4.5 1.1 9.1 2.3 3.7 1.1 8 0.4 98 16 92 255 7.6 0 7.8 7.5 10/08/2005 20:50:00 5.4 1.2 9.1 2.6 5.3 1.3 8.8 1.9 4.5 1.2 8.4 1.9 97 15 109 255 7.7 0 7.8 7.5 10/08/2005 21:00:00 5.4 1.5 9.1 2.3 5.2 1.5 9.1 2.3 4.5 1.3 8.4 1.9 103 15 93 255 7.8 0 7.8 7.8 10/08/2005 21:10:00 4.8 1.4 8.8 1.9 4.7 1.5 8.4 1.5 3.9 1.4 6.8 0.7 95 16 94 255 7.7 0 7.8 7.8 10/08/2005 21:20:00 5.5 1.2 9.1 2.3 5.4 1.2 8.8 2.6 4.7 1.2 7.6 1.9 98 15 88 255 7.6 0.1 7.8 7.3 10/08/2005 21:30:00 6.2 1.1 9.1 3.4 6.1 1.1 9.1 3 5.1 1.2 8.8 2.3 101 15 110 255 7.3 0 7.5 7.3 10/08/2005 21:40:00 4.9 1.2 8.8 2.3 4.9 1.2 8.4 2.3 3.7 1.2 6.8 0.4 106 16 101 255 7.3 0 7.5 7.3 10/08/2005 21:50:00 5 1.1 8 2.3 4.9 1.1 8 2.3 4.1 1 6.8 1.9 101 16 119 255 7.4 0 7.5 7.3 10/08/2005 22:00:00 4.9 1.3 8.4 1.9 4.9 1.3 8 1.1 4 1.3 7.6 0.7 101 14 105 255 7.4 0 7.5 7.3 10/08/2005 22:10:00 4.8 1.1 8.4 1.9 4.9 1.1 8 1.9 3.6 1.2 6.8 1.1 98 17 101 255 7.3 0 7.5 7.3 10/08/2005 22:20:00 4.8 1.1 7.6 2.3 4.7 1.1 8 2.3 4 1 6.8 0.7 107 16 119 255 7.3 0 7.5 7.3 10/08/2005 22:30:00 5.8 1.2 9.1 1.9 5.7 1.2 8.8 1.9 4.7 1.3 7.6 1.1 106 14 113 255 7.3 0 7.3 7.3 10/08/2005 22:40:00 5.8 1.3 9.1 2.6 5.8 1.3 9.5 2.3 4.6 1.2 8.4 1.9 110 18 95 255 7.2 0 7.3 7 10/08/2005 22:50:00 5.2 1.5 8.8 2.6 5.1 1.4 8.8 2.3 4.1 1.5 8.4 1.5 106 17 115 255 7.1 0 7.3 7 10/08/2005 23:00:00 5.5 1.3 9.1 2.3 5.5 1.2 8.8 2.6 4.6 1.3 8.4 1.5 104 15 101 255 7.1 0 7.3 7 10/08/2005 23:10:00 4.9 1.2 8.8 2.3 4.9 1.2 8.8 2.3 3.9 1.2 8 0.4 113 17 119 255 6.9 0 7.3 6.7 10/08/2005 23:20:00 4.9 1.4 8.8 1.9 4.8 1.3 8.8 1.9 4 1.4 7.2 1.5 103 16 115 255 6.7 0 7 6.7 10/08/2005 23:30:00 5.1 1.4 9.9 2.6 4.9 1.4 9.1 2.3 4.2 1.3 8 1.1 102 16 107 255 6.7 0 7 6.7 10/08/2005 23:40:00 5 1.2 8 1.9 4.8 1.2 7.6 1.9 4 1.2 6.8 1.1 100 15 102 255 6.8 0 7 6.7 10/08/2005 23:50:00 4.2 1 6.8 1.9 4.1 1 6.8 1.5 3.3 1.1 6.1 0.7 98 16 101 255 6.7 0 7 6.7 10/09/2005 00:00:00 4 0.9 6.5 1.1 3.8 1 6.1 0.7 3.1 1 5.3 0.7 98 15 104 255 6.6 0 6.7 6.5 10/09/2005 00:10:00 3.4 0.8 6.1 1.1 3.3 0.9 6.1 1.1 2.5 0.9 4.6 0.4 94 16 94 255 6.5 0 6.7 6.5 10/09/2005 00:20:00 4 1.1 7.6 1.1 3.8 1.2 8 1.1 3.1 1.2 6.1 0.7 105 17 134 255 6.4 0 6.7 6.2 10/09/2005 00:30:00 4.6 1.1 6.8 1.9 4.6 1.1 6.8 1.5 3.8 1.3 6.5 0.7 107 14 107 255 6.5 0 6.7 6.2 10/09/2005 00:40:00 4.6 1.2 7.2 1.9 4.6 1.2 7.6 2.3 3.6 1.2 6.8 0.7 106 16 115 255 6.4 0 6.7 6.2 10/09/2005 00:50:00 3.6 1 6.1 1.5 3.4 1 6.1 1.1 2.7 1 4.9 0.4 97 16 101 255 6.2 0 6.5 6.2 10/09/2005 01:00:00 4.3 1.1 6.8 1.1 4.3 1.1 6.8 1.5 3.3 1.1 5.7 1.1 94 15 81 255 6.2 0 6.2 6 10/09/2005 01:10:00 4.2 1 7.2 1.1 4.1 1 6.8 1.1 3.4 1.1 6.1 0.7 94 13 100 255 6.2 0 6.2 6 10/09/2005 01:20:00 3.9 1 6.5 1.1 3.8 1 6.5 1.5 3 1.1 6.1 0.4 95 15 88 255 6.1 0 6.2 6 10/09/2005 01:30:00 4.1 1.1 6.8 1.9 4 1 7.2 1.9 3.1 1 5.7 0.7 101 15 112 255 5.9 0.1 6.2 5.7 10/09/2005 01:40:00 4.1 0.9 6.5 1.9 3.9 1 6.5 1.5 3.1 0.9 5.7 0.7 100 15 74 255 5.8 0 6 5.7 10/09/2005 01:50:00 3.2 0.8 4.9 1.5 3 0.8 4.9 1.1 2.3 0.9 4.2 0.4 88 13 86 255 5.5 0 5.7 5.2 10/09/2005 02:00:00 2.7 0.8 4.6 0.4 2.6 0.8 4.6 0.4 1.6 0.9 4.6 0.4 92 18 105 255 5.2 0.1 5.5 5 10/09/2005 02:10:00 3.2 0.9 5.3 0.7 3.1 0.8 5.3 0.4 2.5 0.9 4.6 0.7 97 12 93 255 5 0 5 4.8 10/09/2005 02:20:00 4.5 0.7 6.5 1.9 4.3 0.8 6.1 1.9 3.4 0.8 5.3 1.5 98 12 94 255 4.9 0 5 4.8 10/09/2005 02:30:00 4.6 0.7 6.1 3 4.5 0.7 5.7 2.6 3.6 0.8 5.7 1.1 101 10 96 255 5.1 0 5 5 10/09/2005 02:40:00 4.1 0.8 6.1 1.9 4 0.8 5.3 1.5 3 0.9 4.9 1.1 106 12 108 255 4.9 0.1 5 4.5 10/09/2005 02:50:00 4.3 0.8 6.1 2.3 4.3 0.8 6.1 2.3 3.3 0.9 5.7 1.5 110 12 104 255 4.6 0 5 4.5 10/09/2005 03:00:00 4.1 0.7 6.1 1.9 3.9 0.7 5.7 2.3 3.1 0.7 4.9 1.5 110 11 117 255 4.6 0 4.8 4.5 10/09/2005 03:10:00 3.7 0.8 5.7 1.9 3.8 0.7 5.7 1.9 2.7 0.8 4.9 0.4 112 13 101 255 4.2 0 4.5 4 10/09/2005 03:20:00 3.7 0.9 5.7 1.1 3.6 0.8 5.3 1.1 2.5 0.8 4.6 0.7 112 13 118 255 4 0 4 3.5 10/09/2005 03:30:00 3.9 0.7 5.3 1.9 3.9 0.7 5.3 1.5 2.9 0.8 4.9 1.5 114 11 85 255 3.8 0 4.3 3.5 10/09/2005 03:40:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 1.9 2.7 0.7 4.6 0.4 113 11 112 255 3.9 0 4.3 3.8 10/09/2005 03:50:00 3.1 0.8 5.7 1.5 2.9 0.8 5.3 1.1 2.1 0.8 4.6 0.4 115 12 115 255 3.5 0.1 4 3.3 10/09/2005 04:00:00 3.6 0.8 5.7 1.9 3.4 0.8 5.7 1.5 2.6 0.9 5.3 0.4 104 13 96 255 3.2 0.1 3.8 2.8 10/09/2005 04:10:00 3.8 0.8 5.7 1.9 3.6 0.8 5.3 1.5 2.8 0.9 5.3 0.7 100 13 95 255 3.5 0 4 3.5 10/09/2005 04:20:00 4 0.7 6.1 2.3 4 0.7 5.7 2.3 3 0.8 5.7 0.7 110 12 108 255 3.7 0 4 3.5 10/09/2005 04:30:00 4.1 0.7 5.7 1.9 4 0.6 5.7 1.9 3.1 0.8 4.9 0.7 105 12 101 255 3.6 0.1 4 3.5 10/09/2005 04:40:00 4 0.8 6.1 1.1 3.9 0.8 6.1 1.5 3 1 5.7 0.4 107 13 94 255 3.6 0 4 3.5 10/09/2005 04:50:00 4.1 0.8 6.5 2.3 4.1 0.8 6.1 2.3 3 0.9 5.3 1.1 99 11 102 255 3.8 0 4 3.5 10/09/2005 05:00:00 4.1 0.8 6.5 1.9 4 0.8 6.5 1.9 3 0.8 4.9 1.1 104 13 125 255 4 0 4.5 3.8 10/09/2005 05:10:00 4.1 0.8 6.8 2.3 3.9 0.8 6.5 1.9 3.1 1 5.7 0.7 104 14 101 255 4.1 0.1 4.8 4 10/09/2005 05:20:00 3.4 0.8 5.7 1.9 3.2 0.8 5.3 1.1 2.3 0.8 4.6 0.4 93 15 104 255 4 0 4.5 4 10/09/2005 05:30:00 2.9 0.9 5.7 0.7 2.7 0.9 5.7 0.4 2.1 0.8 5.3 0.4 94 15 97 255 3.9 0 4 3.8 10/09/2005 05:40:00 3.9 0.7 5.7 1.9 3.7 0.7 5.3 1.1 2.8 0.9 5.3 1.1 108 12 103 255 4 0 4.3 3.8 10/09/2005 05:50:00 4 0.7 6.1 2.3 3.9 0.6 5.7 2.3 3.1 0.8 5.7 1.1 101 11 91 255 4.2 0 4.5 4 10/09/2005 06:00:00 4.4 0.8 6.1 2.3 4.2 0.8 6.1 1.9 3.3 0.9 5.7 1.1 103 11 93 255 4.2 0 4.5 4 10/09/2005 06:10:00 4.2 0.8 6.1 1.9 4.1 0.8 6.1 1.5 3.2 0.8 6.1 1.1 112 13 98 255 4.2 0 4.3 4 10/09/2005 06:20:00 3.7 0.7 6.1 1.9 3.6 0.7 5.3 1.9 2.7 0.7 4.6 0.7 105 10 115 255 4 0 4.3 4 10/09/2005 06:30:00 4.1 0.9 7.2 2.3 3.8 0.9 6.5 1.9 2.9 0.9 4.9 1.1 108 15 122 255 4 0 4.3 4 10/09/2005 06:40:00 4.6 1 7.2 1.5 4.5 1 7.2 1.9 3.5 1.1 6.1 1.1 112 15 110 255 4.3 0 4.5 4 10/09/2005 06:50:00 5 1.1 8 2.3 4.9 1 7.6 2.3 4.1 1.1 7.6 1.5 112 15 112 255 4.5 0 4.5 4.5 10/09/2005 07:00:00 5 1.3 8.4 2.3 4.9 1.2 8.4 1.9 4.1 1.2 7.2 0.7 107 14 87 255 4.4 0 4.5 4.3 10/09/2005 07:10:00 4.7 1 7.2 1.9 4.6 1 7.2 1.9 3.6 1 6.5 1.5 105 13 101 255 4.5 0 4.5 4.5 10/09/2005 07:20:00 4.4 0.9 6.5 1.9 4.2 0.9 6.1 1.5 3.3 1 5.7 0.7 108 15 102 255 4.5 0 4.5 4.5 10/09/2005 07:30:00 4.4 0.9 6.8 1.9 4.2 1 6.8 1.5 3.3 1.1 5.7 0.4 107 15 125 255 4.4 0 4.5 4.3 10/09/2005 07:40:00 4.4 0.8 6.5 1.9 4.3 0.9 6.1 1.5 3.3 0.9 5.7 1.1 105 12 113 255 4.3 0 4.5 4.3 10/09/2005 07:50:00 4.6 0.9 6.5 1.9 4.4 0.9 6.5 1.9 3.6 0.9 6.1 1.1 107 12 99 255 4.5 0 5 4.5 10/09/2005 08:00:00 4.5 0.8 6.8 2.3 4.4 0.8 6.5 2.3 3.5 0.8 5.7 1.5 113 13 110 255 4.6 0 5 4.5 10/09/2005 08:10:00 4.2 0.9 6.1 1.9 4 0.9 6.1 1.9 3.3 0.9 5.7 1.1 111 14 119 255 4.6 0 4.8 4.5 10/09/2005 08:20:00 4.2 1.1 6.8 1.5 4 1 6.5 1.1 3.2 1 5.7 1.1 114 15 110 255 4.9 0 5 4.8 10/09/2005 08:30:00 4.2 0.9 6.5 2.3 4 1 6.1 1.9 3.3 1 5.3 1.5 108 13 115 255 5.1 0 5.5 5 10/09/2005 08:40:00 4.4 0.9 6.5 1.9 4.3 1 6.5 1.9 3.5 1 6.5 1.5 110 15 114 255 5.4 0 5.7 5.2 10/09/2005 08:50:00 4.2 1 6.8 1.9 4.1 1.1 6.8 1.1 3.4 1.1 6.1 0.7 115 18 134 255 5.7 0 6 5.7 10/09/2005 09:00:00 4.9 1 7.6 2.3 4.6 1 6.8 1.9 4.1 1.1 6.8 0.7 109 17 110 255 5.9 0 6 5.7 10/09/2005 09:10:00 4.4 1 6.5 2.3 4.2 1 6.5 1.9 3.7 1 6.5 1.9 108 16 102 255 6.2 0 6.2 6 10/09/2005 09:20:00 3.4 0.8 5.3 1.5 3.2 0.9 5.3 1.1 2.8 0.9 4.9 0.7 98 13 118 255 6.2 0 6.5 6.2 10/09/2005 09:30:00 3.2 0.8 5.7 1.5 3 0.8 5.3 1.1 2.5 1 4.9 0.4 96 17 84 255 6.5 0 6.7 6.2 10/09/2005 09:40:00 3.7 1 5.7 0.7 3.5 1.1 5.7 0.4 3.1 1 5.3 0.7 106 13 102 255 6.7 0 6.7 6.5 10/09/2005 09:50:00 3.3 0.7 5.3 1.9 3 0.7 5.3 1.1 2.8 0.8 5.3 0.7 99 12 99 255 6.7 0 6.7 6.7 10/09/2005 10:00:00 3 0.7 4.9 1.5 2.7 0.8 4.6 0.7 2.3 0.9 4.9 0.4 103 13 97 255 6.7 0 7 6.7 10/09/2005 10:10:00 2.8 0.7 4.6 1.1 2.5 0.8 4.9 0.4 2 0.7 4.2 0.4 102 15 123 255 6.9 0.1 7.3 6.7 10/09/2005 10:20:00 3.2 0.9 4.9 1.5 3 0.9 4.9 0.7 2.7 1 5.3 0.4 102 18 92 255 7.4 0.1 7.5 7.3 10/09/2005 10:30:00 4 0.9 6.1 1.9 3.7 1 5.7 1.1 3.4 1 6.1 1.1 104 15 108 255 7.5 0 7.5 7.5 10/09/2005 10:40:00 3.7 0.8 5.7 1.5 3.5 0.9 5.3 0.7 3 1 5.3 0.7 107 14 103 255 7.4 0 7.5 7.3 10/09/2005 10:50:00 3.5 0.9 5.7 1.1 3.5 0.9 5.3 1.1 2.9 0.9 5.3 0.4 102 14 96 255 7.3 0 7.5 7.3 10/09/2005 11:00:00 2 0.7 3.8 0.4 1.8 0.7 3.4 0.4 1.3 0.7 3.4 0.4 88 23 105 255 7.7 0.2 8 7.3 10/09/2005 11:10:00 2.8 0.7 4.6 0.7 3 0.6 4.6 1.1 2.5 0.8 4.2 0.4 80 17 74 255 8.1 0 8.3 8 10/09/2005 11:20:00 2.8 1 4.9 0.4 2.7 1.1 4.6 0.4 2.4 1 4.6 0.4 100 15 89 255 8 0 8.3 8 10/09/2005 11:30:00 2.4 0.7 4.6 0.7 2.3 0.8 4.2 0.4 2.3 0.7 3.8 0.4 109 18 91 255 8 0 8.3 7.8 10/09/2005 11:40:00 2.7 0.8 4.6 0.4 2.6 0.8 4.6 0.4 2.2 1 4.2 0.4 96 18 98 255 7.9 0 8 7.8 10/09/2005 11:50:00 1.7 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.3 0.9 3.8 0.4 86 23 94 255 8.1 0 8.3 8 10/09/2005 12:00:00 1.8 0.8 3.4 0.4 1.7 0.7 3 0.4 1.4 0.6 3 0.4 79 17 98 255 8.5 0.1 8.8 8.3 10/09/2005 12:10:00 2.9 0.9 4.9 0.7 2.7 0.9 4.9 0.4 2.3 1 4.6 0.4 92 13 79 255 8.9 0 9 8.8 10/09/2005 12:20:00 2.9 0.8 4.6 0.4 2.7 0.8 4.6 0.4 2.4 0.8 4.2 0.4 90 18 90 255 9.2 0 9.3 9 10/09/2005 12:30:00 2.6 1 4.6 0.4 2.5 0.9 4.6 0.4 2.2 0.9 4.6 0.4 92 18 124 255 9.5 0 9.6 9.3 10/09/2005 12:40:00 4.8 1.1 8.4 2.3 4.7 1.1 8 2.6 4.2 1 7.2 1.9 102 17 90 255 9.4 0 9.6 9.3 10/09/2005 12:50:00 3.6 1.2 6.5 0.7 3.6 1.2 6.8 0.4 3.2 1.2 6.8 0.4 98 20 79 255 9.4 0 9.6 9.3 10/09/2005 13:00:00 3.9 1.3 7.2 1.1 3.9 1.2 6.8 1.1 3.3 1.3 6.8 0.4 117 24 126 255 9.7 0 9.8 9.6 10/09/2005 13:10:00 3.4 1 6.1 0.7 3.3 1 5.7 0.4 2.8 1.1 5.3 0.4 116 22 119 255 9.9 0.1 10.3 9.6 10/09/2005 13:20:00 3.8 1.2 6.5 0.7 3.6 1.2 6.5 0.7 3.1 1.2 6.8 0.7 121 22 106 255 10.3 0 10.6 10.3 10/09/2005 13:30:00 2.9 1 5.7 1.1 2.7 1 5.3 0.4 2.4 0.9 4.9 0.4 124 26 108 255 10.6 0 10.9 10.6 10/09/2005 13:40:00 3.7 1.3 8 0.7 3.5 1.3 8.4 0.4 2.8 1.3 5.7 0.4 141 33 136 255 10.8 0 11.1 10.6 10/09/2005 13:50:00 3.7 1.2 7.2 1.1 3.7 1.2 6.8 1.1 3.2 1.3 8 0.4 136 26 162 255 10.6 0 10.9 10.6 10/09/2005 14:00:00 3.2 1 5.7 0.7 3.3 1 5.7 1.5 2.8 1 5.3 0.7 125 23 97 255 10.9 0 11.1 10.6 10/09/2005 14:10:00 1.5 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1 0.8 3.4 0.4 203 38 150 255 11.3 0.1 11.7 11.1 10/09/2005 14:20:00 1.5 0.9 3.4 0.4 1.5 0.9 3.8 0.4 1.2 0.7 3 0.4 203 22 223 255 11.4 0 11.7 11.4 10/09/2005 14:30:00 1.5 0.8 3 0.4 1.3 0.8 3 0.4 1.1 0.7 3 0.4 254 30 306 255 11.1 0 11.4 10.9 10/09/2005 14:40:00 1.4 0.9 3.4 0.4 1.3 0.9 3 0.4 0.8 0.6 2.6 0.4 221 61 291 255 10.9 0 11.1 10.9 10/09/2005 14:50:00 3 0.9 5.3 0.7 3 1 5.3 1.1 2.3 1.1 4.9 0.4 261 21 268 255 10.9 0.1 11.1 10.6 10/09/2005 15:00:00 2.7 1 4.6 0.4 2.7 1 4.6 0.4 1.7 1.1 4.6 0.4 270 20 278 255 10.3 0 10.6 10.1 10/09/2005 15:10:00 2.5 0.7 4.2 0.7 2.4 0.7 3.8 0.7 1.8 0.9 4.6 0.4 290 23 294 255 9.6 0.1 10.1 9.6 10/09/2005 15:20:00 2.1 0.9 4.2 0.4 2.2 0.8 4.2 0.4 1.3 0.9 3.4 0.4 268 41 296 255 9.4 0 9.6 9.3 10/09/2005 15:30:00 1.6 0.6 3.4 0.4 1.5 0.7 3.4 0.4 0.9 0.6 2.6 0.4 296 22 285 255 9.3 0 9.3 9 10/09/2005 15:40:00 1.9 0.6 3.4 0.4 1.8 0.7 3 0.4 1.2 0.8 3.4 0.4 292 22 297 255 9 0 9.3 8.8 10/09/2005 15:50:00 2.1 0.8 3.8 0.4 2.1 0.7 4.2 0.4 1.3 0.8 3.4 0.4 268 16 277 255 8.5 0.1 8.8 8.5 10/09/2005 16:00:00 2.3 0.8 4.2 0.4 2.3 0.8 3.8 0.4 1.5 0.9 3.8 0.4 260 17 271 255 8.3 0 8.5 8.3 10/09/2005 16:10:00 2.7 0.9 4.2 0.4 2.7 0.8 4.2 0.4 1.8 0.9 3.8 0.4 259 18 252 255 8 0 8.3 7.8 10/09/2005 16:20:00 2.6 0.7 4.9 0.7 2.6 0.7 4.6 1.1 1.7 0.8 4.2 0.4 263 15 283 255 7.8 0 7.8 7.8 10/09/2005 16:30:00 2 0.6 3.4 0.4 1.9 0.7 3.8 0.4 1 0.7 3.4 0.4 268 24 284 255 7.8 0 7.8 7.8 10/09/2005 16:40:00 1.7 0.7 3.4 0.4 1.5 0.6 3 0.4 0.9 0.6 3 0.4 275 17 252 255 7.8 0 7.8 7.5 10/09/2005 16:50:00 2 0.8 3.8 0.4 1.9 0.8 3.4 0.4 1.5 0.7 3.4 0.4 268 20 256 255 7.6 0 7.8 7.5 10/09/2005 17:00:00 1.5 0.7 3 0.4 1.3 0.7 3.4 0.4 0.9 0.6 2.3 0.4 277 17 307 255 7.4 0 7.5 7.3 10/09/2005 17:10:00 1.4 0.6 2.6 0.4 1.2 0.6 3 0.4 0.5 0.4 2.3 0.4 275 12 286 255 7.2 0 7.3 7 10/09/2005 17:20:00 1.9 0.5 3.4 0.4 1.7 0.6 3 0.4 1 0.6 2.6 0.4 270 15 253 255 6.8 0 7 6.7 10/09/2005 17:30:00 1.5 0.6 3 0.4 1.3 0.7 2.6 0.4 0.5 0.3 1.9 0.4 262 17 256 255 6.4 0.2 6.7 6.2 10/09/2005 17:40:00 1.7 0.6 2.6 0.4 1.5 0.6 2.6 0.4 0.6 0.4 1.9 0.4 273 13 269 255 6.1 0 6.2 5.7 10/09/2005 17:50:00 1.8 0.5 3 0.7 1.7 0.5 3 0.4 0.6 0.4 1.9 0.4 275 13 274 255 5.5 0.2 6 5 10/09/2005 18:00:00 1.6 0.7 2.6 0.4 1.5 0.7 2.6 0.4 0.6 0.4 1.9 0.4 270 15 277 255 4.8 0.2 5 4.5 10/09/2005 18:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 291 2 293 255 4.1 0.2 4.5 4 10/09/2005 18:20:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.4 0.1 0.7 0.4 268 9 262 255 3.7 0.2 4 3.5 10/09/2005 18:30:00 1.5 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.4 0.1 1.1 0.4 258 2 259 255 3.3 0 3.8 3 10/09/2005 18:40:00 2.4 0.4 3.4 1.1 2.3 0.5 3 0.7 0.8 0.4 1.9 0.4 251 4 253 255 3 0.1 3.5 2.8 10/09/2005 18:50:00 2.4 0.5 3.4 0.7 2.2 0.5 3.4 0.7 0.8 0.5 2.3 0.4 247 9 255 255 3 0 3.5 2.8 10/09/2005 19:00:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.4 0.1 0.7 0.4 221 22 253 255 2.9 0 3.3 2.6 10/09/2005 19:10:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 229 16 219 255 2.5 0.1 3.3 2.3 10/09/2005 19:20:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.4 0.1 0.7 0.4 235 22 229 255 2.3 0 2.6 1.8 10/09/2005 19:30:00 1.2 0.9 3 0.4 1.1 0.8 3 0.4 0.8 0.4 1.5 0.4 183 49 238 255 2 0 2.3 1.8 10/09/2005 19:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 125 20 180 255 2 0 2.1 1.8 10/09/2005 19:50:00 1.6 0.2 2.3 1.1 1.3 0.3 1.9 0.7 0.5 0.2 1.5 0.4 203 9 208 255 2.1 0 2.3 1.8 10/09/2005 20:00:00 1.5 0.4 2.6 0.7 1.7 0.3 2.3 0.7 0.8 0.4 1.5 0.4 176 6 183 255 2 0 2.1 1.8 10/09/2005 20:10:00 2.1 0.6 3.4 1.1 2.2 0.4 3.4 1.5 1.3 0.5 2.3 0.4 181 14 204 255 2.1 0 2.3 1.8 10/09/2005 20:20:00 1.8 0.6 3 0.7 1.6 0.6 3 0.4 0.7 0.4 1.9 0.4 185 13 212 255 2 0 2.3 1.8 10/09/2005 20:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 182 1 182 255 1.8 0 1.8 1.8 10/09/2005 20:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 182 255 1.7 0 1.8 1.6 10/09/2005 20:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 45 75 255 1.5 0 1.6 1.4 10/09/2005 21:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 76 255 1.3 0 1.8 1.4 10/09/2005 21:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 0 76 255 1.4 0.1 1.8 1.4 10/09/2005 21:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 0 75 255 1.3 0 1.6 1.4 10/09/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 1.2 0 1.6 0.9 10/09/2005 21:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 0 75 255 0.9 0.1 1.4 0.9 10/09/2005 21:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 45 184 255 0.8 0.1 1.4 0.7 10/09/2005 22:00:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 182 7 177 255 0.7 0 1.4 0.7 10/09/2005 22:10:00 1.5 0.2 1.9 0.7 1 0.3 1.9 0.4 0.6 0.3 1.1 0.4 142 6 139 255 0.5 0 0.9 0.4 10/09/2005 22:20:00 2.3 0.4 3 1.1 2 0.5 3 0.4 1.4 0.3 2.3 0.4 133 6 133 255 0.1 0 0.7 -0.1 10/09/2005 22:30:00 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.9 1.8 0.3 2.6 1.1 132 6 131 255 -0.3 0 -0.1 -0.5 10/09/2005 22:40:00 2.7 0.3 3.4 1.5 2.6 0.3 3 1.5 1.7 0.3 2.6 0.7 134 5 139 255 -0.6 0 -0.5 -0.7 10/09/2005 22:50:00 2.5 0.4 3.4 1.5 2.4 0.4 3 1.1 1.7 0.5 3.8 0.7 134 8 127 255 -0.6 0 -0.5 -0.7 10/09/2005 23:00:00 2.8 0.4 3.8 1.5 2.8 0.5 3.8 1.1 2.1 0.5 3 0.7 133 7 121 255 -0.5 0 -0.5 -0.7 10/09/2005 23:10:00 2.4 0.5 3.4 1.1 2.4 0.5 3.4 0.7 1.8 0.5 3.4 0.4 134 7 138 255 -0.6 0.1 -0.5 -0.7 10/09/2005 23:20:00 2 0.3 2.6 1.5 1.7 0.3 2.6 1.1 1 0.3 1.9 0.4 142 7 122 255 -1 0 -0.5 -1 10/09/2005 23:30:00 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 137 3 143 255 -0.9 0 -0.7 -1 10/09/2005 23:40:00 1.7 0.3 2.3 0.7 1.3 0.3 1.9 0.4 0.4 0 0.4 0.4 96 8 94 255 -0.9 0 -0.5 -1 10/09/2005 23:50:00 1.6 0.3 2.3 1.1 1.3 0.4 2.3 0.4 0.4 0.1 1.1 0.4 77 16 73 255 -1 0 -0.7 -1.2 10/10/2005 00:00:00 1.9 0.5 3 0.7 1.7 0.5 2.6 0.4 0.8 0.4 1.9 0.4 68 9 63 255 -1.1 0 -1 -1.2 10/10/2005 00:10:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1 0.4 1.9 0.4 83 15 84 255 -1.1 0 -1 -1.2 10/10/2005 00:20:00 2.1 0.4 3.4 1.1 1.9 0.5 3 0.7 0.8 0.5 2.3 0.4 99 18 76 255 -1 0 -0.7 -1.2 10/10/2005 00:30:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 0.8 0.5 1.9 0.4 91 12 88 255 -1 0 -0.7 -1.2 10/10/2005 00:40:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 1.5 0.4 2.6 0.4 75 9 80 255 -0.9 0 -0.7 -1 10/10/2005 00:50:00 2.8 0.3 3.8 1.9 2.7 0.3 4.2 1.9 1.6 0.4 2.6 0.4 78 9 75 255 -0.7 0 -0.5 -0.7 10/10/2005 01:00:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 1.1 1.3 0.5 2.6 0.4 78 11 77 255 -0.6 0 -0.5 -0.7 10/10/2005 01:10:00 2.6 0.3 3.4 1.5 2.5 0.4 3.4 1.1 1.6 0.4 2.3 0.4 75 8 88 255 -0.5 0 -0.5 -0.5 10/10/2005 01:20:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.7 0.4 2.6 0.4 74 8 97 255 -0.5 0 -0.5 -0.5 10/10/2005 01:30:00 2.8 0.4 4.2 1.9 2.7 0.4 4.2 1.9 1.8 0.4 3 0.7 72 8 73 255 -0.5 0 -0.5 -0.5 10/10/2005 01:40:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 1.5 0.4 2.6 0.4 73 10 80 255 -0.3 0 -0.1 -0.5 10/10/2005 01:50:00 2.7 0.4 3.8 1.5 2.5 0.5 3.8 1.5 1.3 0.5 2.6 0.4 84 10 75 255 -0.2 0 -0.1 -0.3 10/10/2005 02:00:00 2.7 0.5 4.2 1.5 2.5 0.5 3.8 1.1 1.4 0.5 2.6 0.4 80 10 70 255 0 0 0.2 -0.1 10/10/2005 02:10:00 2.7 0.4 3.8 1.9 2.6 0.4 3.4 1.1 1.7 0.4 3 0.7 71 11 84 255 0.2 0 0.2 0.2 10/10/2005 02:20:00 2.7 0.5 4.2 1.5 2.6 0.5 3.8 1.1 1.7 0.5 3 0.4 78 9 73 255 0.3 0 0.7 0.2 10/10/2005 02:30:00 2.7 0.4 4.2 1.9 2.5 0.5 3.8 1.1 1.4 0.5 3 0.4 86 11 69 255 0.2 0.1 0.4 0.2 10/10/2005 02:40:00 2.6 0.4 3.4 1.9 2.4 0.4 3.4 1.5 1.2 0.5 2.3 0.4 94 10 95 255 0.1 0 0.2 -0.1 10/10/2005 02:50:00 2.6 0.4 3.8 1.5 2.4 0.4 3.8 1.5 1.1 0.4 2.3 0.4 94 11 93 255 0.1 0 0.2 -0.1 10/10/2005 03:00:00 2.6 0.3 3.4 1.5 2.4 0.4 3.4 1.5 1.2 0.5 2.3 0.4 100 11 89 255 -0.1 0 -0.1 -0.1 10/10/2005 03:10:00 2.8 0.4 3.8 1.5 2.6 0.5 3.8 1.1 1.3 0.6 2.6 0.4 105 11 101 255 -0.2 0 -0.1 -0.3 10/10/2005 03:20:00 2.8 0.4 3.8 1.5 2.6 0.5 4.2 1.1 1.6 0.5 2.6 0.4 107 10 111 255 -0.2 0 -0.1 -0.3 10/10/2005 03:30:00 3.1 0.3 4.2 2.3 2.9 0.3 3.8 1.9 1.9 0.4 2.6 0.7 102 8 108 255 -0.2 0 -0.1 -0.3 10/10/2005 03:40:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 2 0.5 3.4 0.7 107 10 98 255 -0.3 0.1 -0.1 -0.5 10/10/2005 03:50:00 3.4 0.5 4.6 1.9 3.2 0.5 4.2 1.9 2.1 0.6 3.4 0.4 106 10 97 255 -0.2 0 -0.1 -0.3 10/10/2005 04:00:00 3.2 0.5 4.2 1.9 2.9 0.6 4.2 1.1 2 0.6 3.4 0.4 111 12 110 255 -0.1 0 0.2 -0.3 10/10/2005 04:10:00 2.9 0.5 4.2 1.5 2.8 0.5 3.8 1.1 1.7 0.5 3 0.4 105 10 103 255 -0.1 0 0.2 -0.1 10/10/2005 04:20:00 2.7 0.4 3.8 1.1 2.5 0.5 3.8 0.7 1.4 0.5 2.6 0.4 103 9 107 255 -0.2 0 0.2 -0.3 10/10/2005 04:30:00 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.5 1.4 0.5 2.6 0.4 104 9 100 255 -0.3 0 -0.1 -0.5 10/10/2005 04:40:00 3 0.3 3.8 2.3 2.9 0.3 3.4 1.9 1.8 0.4 2.6 0.7 100 8 98 255 -0.5 0 -0.3 -0.5 10/10/2005 04:50:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.1 1.6 0.6 3 0.4 103 8 100 255 -0.6 0 -0.5 -0.7 10/10/2005 05:00:00 3.2 0.5 4.2 1.9 3 0.5 3.8 1.5 1.9 0.6 3.4 0.4 108 11 109 255 -0.7 0.1 -0.5 -1 10/10/2005 05:10:00 3.2 0.6 4.2 1.5 3 0.6 4.2 1.5 1.8 0.6 3.4 0.4 111 9 90 255 -0.9 0 -0.7 -1.2 10/10/2005 05:20:00 3.7 0.5 4.9 1.9 3.5 0.5 4.9 1.9 2.2 0.6 3.8 0.7 108 11 94 255 -0.9 0 -0.7 -1.2 10/10/2005 05:30:00 4 0.6 5.7 2.3 3.8 0.7 5.3 1.9 2.5 0.7 4.6 1.1 109 8 118 255 -0.8 0 -0.5 -1 10/10/2005 05:40:00 4 0.6 5.7 1.9 3.8 0.6 5.3 1.9 2.5 0.7 4.6 0.4 109 9 110 255 -0.2 0.1 0.2 -0.5 10/10/2005 05:50:00 3.7 0.6 4.6 1.5 3.5 0.6 4.6 1.9 2.2 0.7 3.8 0.4 108 9 113 255 -0.4 0.2 -0.1 -0.7 10/10/2005 06:00:00 1.1 0.8 3.4 0.4 1 0.8 3 0.4 0.4 0.3 2.3 0.4 145 41 109 255 -0.8 0 -0.7 -0.7 10/10/2005 06:10:00 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 0.5 0.4 1.9 0.4 111 19 99 255 -0.6 0 -0.5 -0.7 10/10/2005 06:20:00 2.2 0.7 3.8 0.4 1.9 0.7 3.4 0.4 0.9 0.6 3 0.4 112 12 121 255 -0.3 0 -0.1 -0.5 10/10/2005 06:30:00 3 0.5 4.2 1.9 2.8 0.5 3.8 1.5 1.7 0.6 3.4 0.4 110 9 113 255 -0.1 0 0.2 -0.3 10/10/2005 06:40:00 3 0.5 3.8 1.5 2.8 0.5 3.8 1.1 1.9 0.6 3.4 0.4 102 9 99 255 0.2 0 0.4 0.2 10/10/2005 06:50:00 3.5 0.3 4.2 2.6 3.3 0.3 4.2 2.3 2.6 0.5 4.2 1.5 106 5 103 255 0.7 0.2 1.4 0.4 10/10/2005 07:00:00 3.8 0.4 4.6 2.3 3.6 0.4 4.6 2.3 2.4 0.6 3.8 0.7 108 8 117 255 1 0.1 1.4 0.9 10/10/2005 07:10:00 3.8 0.5 4.6 2.3 3.6 0.5 4.6 1.9 2.5 0.6 3.8 0.7 109 8 97 255 1.1 0 1.4 0.9 10/10/2005 07:20:00 3.8 0.4 4.6 2.3 3.6 0.4 4.6 2.3 2.6 0.5 3.8 1.1 106 7 112 255 1.1 0 1.4 0.9 10/10/2005 07:30:00 3.6 0.5 4.6 1.9 3.5 0.5 4.6 1.5 2.5 0.6 3.8 1.1 107 8 102 255 1 0 1.4 0.9 10/10/2005 07:40:00 3.4 0.4 4.2 2.3 3.2 0.4 3.8 1.9 2.2 0.5 3.4 0.7 109 7 108 255 1.3 0 1.6 1.4 10/10/2005 07:50:00 2.8 0.5 3.8 1.1 2.5 0.5 3.4 0.7 1.8 0.5 3.4 0.7 113 10 116 255 1.5 0 1.6 1.4 10/10/2005 08:00:00 2.1 0.5 3.4 0.7 1.8 0.6 3 0.4 0.8 0.5 2.3 0.4 117 11 101 255 1.5 0 1.6 1.6 10/10/2005 08:10:00 2.1 0.6 3.4 0.4 1.9 0.7 3.4 0.4 0.9 0.6 2.6 0.4 118 10 115 255 1.6 0 1.8 1.4 10/10/2005 08:20:00 1.8 0.5 3 0.4 1.6 0.6 3 0.4 1 0.5 2.6 0.4 125 10 115 255 1.7 0 1.8 1.6 10/10/2005 08:30:00 2.5 0.6 3.8 1.1 2.2 0.6 3.4 0.4 1.3 0.6 2.6 0.4 114 9 112 255 1.7 0 1.8 1.6 10/10/2005 08:40:00 3.4 0.3 4.2 2.3 3.2 0.3 3.8 2.3 2 0.5 3.4 0.7 103 7 102 255 1.7 0 1.8 1.6 10/10/2005 08:50:00 2.9 0.4 3.8 1.9 2.6 0.4 3.4 1.5 1.8 0.5 2.6 0.7 94 5 93 255 2 0.2 2.3 1.8 10/10/2005 09:00:00 2.7 0.4 3.4 1.9 2.5 0.4 3.4 1.5 1.6 0.5 2.6 0.4 94 6 93 255 2.4 0 2.6 2.3 10/10/2005 09:10:00 2.6 0.3 3.4 1.5 2.3 0.4 3.4 1.1 1.6 0.5 2.6 0.4 93 8 92 255 2.8 0.1 3 2.6 10/10/2005 09:20:00 2.7 0.4 3.8 1.5 2.4 0.4 3.4 1.1 1.6 0.4 2.6 0.7 96 7 94 255 3.3 0.1 3.5 3 10/10/2005 09:30:00 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 2.1 0.6 3.4 0.4 101 8 104 255 3.8 0.1 4.3 3.5 10/10/2005 09:40:00 2.9 0.5 3.8 1.1 2.6 0.6 3.4 0.4 1.9 0.7 3 0.4 106 9 108 255 4.4 0.1 4.8 4 10/10/2005 09:50:00 2.9 0.5 4.2 1.5 2.5 0.7 3.8 0.4 2.1 0.6 3.4 0.7 111 11 118 255 4.8 0 5 4.5 10/10/2005 10:00:00 1.7 0.7 3 0.4 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 115 21 102 255 5 0 5 4.8 10/10/2005 10:10:00 0.8 0.5 2.6 0.4 0.5 0.4 2.3 0.4 0.4 0.1 1.1 0.4 125 33 121 255 5.1 0 5.2 5 10/10/2005 10:20:00 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 113 21 110 255 5.3 0 5.7 5.2 10/10/2005 10:30:00 1.7 0.5 3 0.4 1.4 0.6 2.6 0.4 1 0.5 2.3 0.4 90 16 96 255 5.6 0 5.7 5.5 10/10/2005 10:40:00 2.1 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.4 0.7 3.4 0.4 99 16 103 255 6 0 6.2 5.7 10/10/2005 10:50:00 0.9 0.6 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.4 1.9 0.4 68 30 65 255 6.4 0 6.7 6.2 10/10/2005 11:00:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 70 17 77 255 6.8 0 7 6.7 10/10/2005 11:10:00 1.9 1 4.2 0.4 1.7 1 3.8 0.4 1.4 0.8 3.8 0.4 94 21 112 255 7 0 7.3 7 10/10/2005 11:20:00 2.3 1 4.9 0.4 2 1 4.6 0.4 1.7 1 4.2 0.4 76 26 81 255 7.3 0 7.5 7.3 10/10/2005 11:30:00 1.5 1 4.2 0.4 1.3 0.9 4.2 0.4 1.1 0.8 3.4 0.4 86 32 97 255 7.8 0 8 7.5 10/10/2005 11:40:00 2 0.8 4.2 0.4 1.7 0.8 3.8 0.4 1.5 0.8 3.4 0.4 82 20 89 255 8 0.1 8.5 7.8 10/10/2005 11:50:00 1.8 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.3 0.6 3.4 0.4 60 41 91 255 8.7 0.1 9 8.5 10/10/2005 12:00:00 1.6 0.6 3 0.4 1.4 0.6 2.6 0.4 1 0.5 2.6 0.4 29 36 76 255 9.1 0 9.3 9 10/10/2005 12:10:00 1.6 0.6 3 0.4 1.2 0.5 2.6 0.4 0.9 0.6 2.6 0.4 348 22 335 255 9.4 0 9.6 9.3 10/10/2005 12:20:00 2.4 0.6 3.8 0.7 2.2 0.6 3.8 0.4 1.8 0.8 3.4 0.4 25 15 30 255 9.4 0 9.6 9.3 10/10/2005 12:30:00 2.6 0.4 3.8 1.5 2.4 0.5 3.4 1.1 2.1 0.5 3.4 0.7 42 16 74 255 9.4 0 9.6 9.3 10/10/2005 12:40:00 2.2 0.8 3.8 0.4 2 1 3.4 0.4 1.8 1 3.8 0.4 22 36 41 255 9.2 0 9.3 9 10/10/2005 12:50:00 1.7 0.6 3 0.4 1.4 0.7 2.6 0.4 1 0.6 2.6 0.4 3 15 0 255 9.6 0.1 9.8 9.3 10/10/2005 13:00:00 2.1 0.6 3.4 0.7 1.8 0.6 3 0.4 1.2 0.7 3 0.4 1 13 1 255 9.7 0 9.8 9.6 10/10/2005 13:10:00 3.3 0.9 6.5 1.9 3.1 1 6.5 1.1 2.5 1.2 6.1 0.4 24 14 34 255 9.7 0 9.8 9.6 10/10/2005 13:20:00 4.7 0.8 6.5 2.6 4.6 0.8 6.8 2.3 3.8 0.9 6.1 1.1 26 12 37 255 9.3 0 9.6 9.3 10/10/2005 13:30:00 5.8 1 9.5 3 5.7 1 9.5 2.6 4.9 1.2 8.8 1.5 29 14 23 255 9.4 0 9.6 9.3 10/10/2005 13:40:00 5.8 1.3 8.8 3 5.7 1.3 8.8 2.6 4.7 1.4 8.8 2.3 38 17 39 255 9 0.3 9.3 8.5 10/10/2005 13:50:00 4.8 1 7.6 2.3 4.7 1 7.6 1.9 4.1 1 6.8 1.5 46 14 45 255 8.3 0 8.5 8.3 10/10/2005 14:00:00 5 0.9 7.6 3 4.9 1 7.6 2.3 4.4 1 7.6 2.3 42 17 45 255 8.2 0 8.5 8.3 10/10/2005 14:10:00 5.3 1.2 8.4 2.6 5.2 1.3 8.4 2.6 4.5 1.2 7.6 1.9 46 16 63 255 8.5 0.1 8.8 8.3 10/10/2005 14:20:00 5.8 1.2 9.5 3 5.7 1.2 9.5 3 5 1.3 8 2.3 40 15 63 255 8.3 0 8.5 8.3 10/10/2005 14:30:00 5.4 1.3 8.8 2.3 5.3 1.3 8.4 1.9 4.7 1.2 7.6 1.9 41 16 55 255 8.9 0.2 9.3 8.5 10/10/2005 14:40:00 5.3 1.1 8.8 1.5 5.2 1.1 8.8 2.3 4.7 1.2 8.4 2.3 59 18 37 255 9.4 0.1 9.6 9 10/10/2005 14:50:00 6.8 1.3 10.3 3.8 6.7 1.3 10.7 3.4 5.8 1.4 9.1 2.6 36 13 32 255 9.7 0 9.8 9.3 10/10/2005 15:00:00 6.9 1.5 11.1 3.4 6.9 1.5 10.7 3.4 6 1.6 9.9 3 47 15 4 255 9.5 0.3 9.8 9 10/10/2005 15:10:00 7.9 1 10.7 4.9 7.9 1.1 10.7 5.3 6.7 1.4 10.7 2.6 33 14 28 255 8.9 0 9 8.8 10/10/2005 15:20:00 6.4 1.2 10.3 3.4 6.4 1.2 10.3 3.8 5.7 1.1 8.8 3 46 14 42 255 8.9 0 9 8.8 10/10/2005 15:30:00 7 1.3 10.3 3.4 7 1.3 10.3 3.4 6 1.5 9.9 3 37 12 20 255 8.9 0 9 8.5 10/10/2005 15:40:00 7.2 1.3 10.3 4.2 7.2 1.3 10.7 4.2 6.2 1.4 10.3 3.4 34 13 47 255 8.2 0.2 8.8 7.8 10/10/2005 15:50:00 7.4 1.6 11.5 4.2 7.3 1.6 11.5 3.8 6.2 1.5 9.9 2.6 41 14 17 255 7.5 0.2 7.8 7.3 10/10/2005 16:00:00 7.1 1.6 11.5 3.4 7.1 1.6 11.1 3.4 6.1 1.7 11.1 2.3 45 13 32 255 6.6 0.3 7.3 6.2 10/10/2005 16:10:00 5.6 1.2 9.5 2.3 5.6 1.2 9.1 2.3 4.9 1.2 8.4 1.9 56 15 58 255 5.9 0.1 6.2 5.7 10/10/2005 16:20:00 6.2 1.3 9.5 3.4 6.2 1.4 9.5 3 5.2 1.2 8 2.6 57 15 40 255 5.6 0 5.7 5.5 10/10/2005 16:30:00 4.1 1.2 7.2 1.5 4.1 1.1 7.2 1.5 3.4 1.2 7.2 0.4 66 15 53 255 5.7 0 5.7 5.5 10/10/2005 16:40:00 4.3 1.1 7.2 1.5 4.4 1.2 7.2 1.5 3.6 1.2 6.5 1.1 60 17 68 255 5.7 0 5.7 5.5 10/10/2005 16:50:00 5.2 1 8 2.3 5.3 1 8 1.9 4.4 0.9 6.5 1.9 49 14 44 255 5.4 0 5.7 5.2 10/10/2005 17:00:00 4.3 1.2 7.2 1.1 4.4 1.2 7.2 1.5 3.7 1.1 6.5 1.5 53 14 51 255 5.2 0 5.5 5.2 10/10/2005 17:10:00 5.4 1.5 9.9 2.3 5.5 1.5 9.5 2.3 4.6 1.5 8 1.1 51 15 22 255 5.2 0 5.5 5 10/10/2005 17:20:00 5.5 1 8.4 2.6 5.5 1.1 8 2.6 4.6 1.1 7.6 1.9 53 13 53 255 5.1 0 5 5 10/10/2005 17:30:00 5.4 1 8.8 3 5.4 1 8.8 2.6 4.7 1.2 8.8 2.3 44 12 40 255 4.9 0 5 4.8 10/10/2005 17:40:00 5 1 8 2.6 5 1 7.6 3 4.3 1.1 7.2 1.9 44 13 39 255 4.8 0 5 4.8 10/10/2005 17:50:00 5.1 1 7.6 2.6 5.1 1 7.6 2.6 4.2 1.1 6.5 1.5 51 13 34 255 4.6 0 4.8 4.5 10/10/2005 18:00:00 5.2 1 8.4 2.6 5.2 1 8.4 3 4.3 1.1 8 1.9 48 13 43 255 4.5 0 4.5 4.5 10/10/2005 18:10:00 4.2 1.2 7.2 1.9 4.3 1.2 7.2 1.9 3.4 1 6.1 1.1 56 15 51 255 4.4 0 4.5 4.3 10/10/2005 18:20:00 5.1 1.1 8 2.6 5.1 1.1 8 2.3 4.3 1.1 7.6 1.5 50 13 55 255 4.3 0 4.5 4.3 10/10/2005 18:30:00 5.6 1 8.8 3 5.6 1.1 8.4 2.6 4.7 1.2 8 1.5 50 13 64 255 4.1 0 4.5 4 10/10/2005 18:40:00 4.8 1.2 7.6 2.3 4.8 1.1 7.6 2.3 4.1 1.1 7.2 1.5 53 13 55 255 4 0 4.3 4 10/10/2005 18:50:00 5.1 1.1 7.6 2.3 5.2 1.1 8 2.3 4.3 1.1 7.6 1.5 57 11 60 255 3.9 0 4 3.8 10/10/2005 19:00:00 5.6 1 8.4 2.3 5.6 1.1 8 2.6 4.6 1.1 7.2 2.3 52 13 42 255 3.7 0 3.8 3.5 10/10/2005 19:10:00 5.1 1.1 7.6 2.6 5.1 1.1 7.6 2.6 4.1 1.2 6.8 1.5 56 13 86 255 3.5 0 3.8 3.5 10/10/2005 19:20:00 4.9 0.9 7.6 2.6 4.9 0.9 7.6 2.6 3.9 0.9 6.8 1.9 54 12 49 255 3.5 0 3.5 3.5 10/10/2005 19:30:00 4.7 0.9 7.2 2.3 4.7 0.9 7.2 2.6 3.7 0.9 6.1 1.5 62 12 77 255 3.4 0 3.5 3.5 10/10/2005 19:40:00 5.7 1 8.8 2.6 5.7 1 8 3 4.5 1 7.2 1.5 56 11 67 255 3.6 0 3.8 3.5 10/10/2005 19:50:00 6.3 1 8.8 3 6.2 1 8.8 3 4.8 1 6.8 1.9 56 12 55 255 3.9 0 4 3.8 10/10/2005 20:00:00 6 1.3 9.1 2.6 6 1.3 9.1 2.6 4.7 1.3 8.4 1.9 60 15 42 255 4.3 0 4.5 4 10/10/2005 20:10:00 5.5 1.1 8.8 1.9 5.4 1.1 9.1 1.5 4.2 1.2 7.2 0.7 60 16 91 255 4.4 0 4.5 4.3 10/10/2005 20:20:00 4.6 1.1 7.6 2.3 4.5 1.2 8 1.9 3.9 1.2 6.8 1.5 71 15 63 255 4.3 0 4.5 4.3 10/10/2005 20:30:00 4 0.9 6.5 1.5 3.8 0.9 6.1 1.5 3 0.9 5.3 0.7 72 18 62 255 4 0 4.3 4 10/10/2005 20:40:00 3.5 0.9 6.1 1.5 3.3 1 5.7 1.1 2.7 1 5.3 0.4 88 19 70 255 3.9 0 4 3.8 10/10/2005 20:50:00 2.9 0.9 5.3 0.7 2.7 1 5.3 0.4 2.2 1 4.6 0.4 95 22 102 255 3.8 0 4 3.8 10/10/2005 21:00:00 3.5 1.3 8 1.1 3.4 1.3 8 0.4 2.8 1.1 6.5 0.4 85 19 77 255 3.5 0 3.8 3.5 10/10/2005 21:10:00 4.4 1.1 7.2 1.5 4.2 1.2 7.2 1.1 3.4 1 6.1 1.1 72 16 63 255 3.6 0 3.8 3.5 10/10/2005 21:20:00 5.6 1 8.8 3 5.6 1.1 8.8 2.6 4.8 1 7.6 2.6 67 15 85 255 3.8 0 3.8 3.5 10/10/2005 21:30:00 6.2 1.2 9.1 3 6.1 1.3 9.1 3 5 1.2 8.4 1.9 63 16 61 255 3.8 0 4 3.8 10/10/2005 21:40:00 6.1 1.2 8.8 2.3 6.1 1.2 9.1 2.3 4.8 1.3 8.4 1.9 62 15 97 255 3.8 0 4 3.8 10/10/2005 21:50:00 6.2 1 10.3 3.4 6.2 1.1 11.1 3.8 5.1 1 8 2.3 58 15 37 255 3.6 0 3.8 3.5 10/10/2005 22:00:00 7.4 1.5 10.7 3.8 7.4 1.5 10.7 3.8 6.2 1.3 9.5 3 55 14 55 255 3.9 0 4 3.5 10/10/2005 22:10:00 6.4 1.2 9.9 3 6.4 1.3 10.3 3 5.5 1.2 8.8 2.3 55 13 73 255 4 0 4 3.8 10/10/2005 22:20:00 7.3 1.3 10.3 3.4 7.3 1.3 10.7 3.4 6.2 1.3 9.5 3.4 59 13 80 255 4.1 0 4.5 4 10/10/2005 22:30:00 6.5 1.5 9.5 3 6.4 1.5 9.5 2.6 5.4 1.4 9.1 1.5 53 13 39 255 4.1 0 4.5 4 10/10/2005 22:40:00 6.6 1.2 10.3 3 6.6 1.3 11.1 3 5.4 1.3 10.3 2.3 57 15 46 255 4.1 0 4.3 4 10/10/2005 22:50:00 6.8 1.4 11.1 3 6.7 1.5 11.1 3.4 5.5 1.6 9.5 2.3 55 15 42 255 4.1 0 4.3 4 10/10/2005 23:00:00 5.4 1.3 9.1 1.9 5.3 1.3 9.1 1.9 4.3 1.3 8 0.4 72 16 71 255 4.1 0 4.3 4 10/10/2005 23:10:00 4.9 1 8.8 2.6 4.8 1 8.8 2.3 4.1 1 7.2 1.5 80 17 64 255 4.2 0 4.5 4 10/10/2005 23:20:00 5.2 1 7.6 2.3 5 1.1 7.2 1.9 4.2 1.2 7.2 1.9 96 15 95 255 4.3 0 4.5 4.3 10/10/2005 23:30:00 5.3 0.9 7.2 3 5 1 7.2 2.3 4.2 1 6.8 0.7 99 12 124 255 4.3 0 4.3 4.3 10/10/2005 23:40:00 4.9 1.3 8.8 1.9 4.7 1.3 9.1 1.9 4 1.3 8.4 1.5 93 29 55 255 4.1 0 4.5 4 10/10/2005 23:50:00 5.8 1.5 10.3 2.6 5.7 1.6 10.7 2.3 4.7 1.5 9.5 0.7 75 19 74 255 4.1 0 4.3 4 10/11/2005 00:00:00 5.4 0.9 8.4 2.6 5.2 1 8 2.6 4.4 1 7.2 1.9 92 13 98 255 4.1 0 4.3 4 10/11/2005 00:10:00 4.5 1.1 8.4 2.3 4.4 1.2 8.4 1.9 3.4 1 6.5 0.7 85 17 63 255 4.2 0 4.5 4.3 10/11/2005 00:20:00 5.1 1.3 8.8 2.3 4.9 1.3 9.1 2.3 4 1.3 7.2 1.1 74 17 62 255 4.5 0 4.8 4.3 10/11/2005 00:30:00 5.3 1.4 9.9 2.6 5.1 1.4 9.9 2.3 4.3 1.4 8.8 1.5 81 16 62 255 4.6 0 4.8 4.5 10/11/2005 00:40:00 4.9 1.1 7.6 2.6 4.8 1.1 7.2 2.3 3.9 1.2 6.8 1.1 85 17 87 255 4.4 0 4.5 4.3 10/11/2005 00:50:00 5.5 1.3 9.9 3 5.4 1.3 9.5 2.6 4.5 1.2 8 1.5 72 15 58 255 4.7 0 4.8 4.5 10/11/2005 01:00:00 5.1 1.2 8 1.9 4.9 1.3 8 1.9 4.2 1.2 7.2 1.5 80 17 91 255 4.6 0 4.8 4.5 10/11/2005 01:10:00 5.5 1.1 8.4 3 5.3 1.2 8.8 2.6 4.4 1.2 7.2 1.5 84 15 77 255 4.6 0 4.8 4.5 10/11/2005 01:20:00 4.8 0.8 7.6 2.6 4.5 1 7.2 1.5 3.7 0.9 6.5 1.5 87 12 78 255 4.3 0.1 4.5 4 10/11/2005 01:30:00 4.2 0.8 6.8 2.3 3.9 0.9 6.5 1.9 3.1 1 6.8 0.7 82 15 62 255 3.9 0 4.3 3.8 10/11/2005 01:40:00 4.6 1 7.2 2.3 4.4 1 6.8 1.5 3.7 1 6.1 0.7 75 16 20 255 3.9 0 4.3 3.8 10/11/2005 01:50:00 4.7 1 7.2 2.6 4.5 1 6.8 1.9 3.5 1.1 6.5 0.7 84 16 64 255 4 0 4.5 3.8 10/11/2005 02:00:00 4.9 1.1 7.2 2.3 4.8 1.1 6.8 1.9 3.9 1.2 6.5 1.1 86 12 90 255 4 0 4 3.8 10/11/2005 02:10:00 5.2 1 8.4 3 5 1 8.4 2.3 4 1 6.5 1.9 92 12 88 255 4 0 4.5 4 10/11/2005 02:20:00 4.9 1 7.6 3 4.7 1 7.2 2.6 3.8 1 6.5 1.1 90 15 82 255 4.2 0 4.8 4 10/11/2005 02:30:00 4.6 0.8 7.2 2.3 4.3 0.8 6.8 2.3 3.5 0.9 6.5 1.1 87 13 80 255 4.2 0 4.5 4.3 10/11/2005 02:40:00 4.4 0.7 6.1 2.6 4.2 0.7 5.7 2.3 3.3 0.8 5.7 0.7 95 12 80 255 4.3 0 4.5 4.3 10/11/2005 02:50:00 4.8 0.9 7.6 2.6 4.5 1 7.2 2.3 3.7 1 6.5 1.5 105 12 104 255 4 0 4.3 3.8 10/11/2005 03:00:00 4.6 0.7 6.8 2.6 4.3 0.7 6.5 2.3 3.7 0.8 5.3 1.5 105 12 97 255 3.6 0.1 3.8 3.5 10/11/2005 03:10:00 4.5 0.7 6.1 2.6 4.2 0.8 6.1 2.3 3.2 0.9 5.3 0.7 100 12 103 255 3.2 0.1 3.5 3 10/11/2005 03:20:00 3.9 0.7 6.1 1.9 3.6 0.7 5.3 1.5 2.7 0.7 4.6 1.1 84 10 97 255 3.1 0 3.3 3 10/11/2005 03:30:00 3.8 0.7 5.7 1.9 3.6 0.7 5.3 1.5 2.4 0.8 4.2 0.7 80 13 129 255 3.1 0 3.3 2.8 10/11/2005 03:40:00 3.5 0.7 5.7 1.9 3.3 0.8 5.3 1.5 2.4 0.7 4.6 0.7 88 13 80 255 2.9 0 3 2.8 10/11/2005 03:50:00 4.3 0.7 6.1 2.6 4.1 0.7 5.7 2.3 3.2 0.7 4.9 1.5 90 10 94 255 3 0 3.3 2.8 10/11/2005 04:00:00 4.9 0.7 6.5 2.6 4.7 0.7 6.5 2.6 3.9 0.7 6.1 1.9 87 10 93 255 3.1 0.1 3.5 2.8 10/11/2005 04:10:00 4.7 0.7 6.5 3 4.5 0.7 6.5 2.6 3.6 0.8 4.9 1.5 99 10 90 255 3.5 0 3.5 3.3 10/11/2005 04:20:00 4.8 0.7 6.8 3 4.6 0.7 6.1 2.6 3.8 0.7 6.1 1.9 93 11 113 255 3.1 0.1 3.5 2.8 10/11/2005 04:30:00 5 0.8 7.2 2.6 4.8 0.9 6.8 2.3 3.8 0.9 6.1 1.9 108 12 95 255 2.9 0 3 2.8 10/11/2005 04:40:00 4.8 0.8 6.5 2.6 4.7 0.8 6.1 2.6 3.6 0.7 5.3 1.9 102 12 108 255 2.9 0 3 2.8 10/11/2005 04:50:00 4.5 0.5 5.7 3 4.3 0.5 5.3 2.6 3.3 0.7 4.9 1.5 104 11 100 255 2.8 0 2.8 2.6 10/11/2005 05:00:00 4.3 0.8 6.1 2.3 4.1 0.8 6.1 2.3 3 0.9 5.3 1.1 115 12 114 255 2.6 0 2.8 2.6 10/11/2005 05:10:00 4.2 0.7 6.1 2.3 4.1 0.6 5.7 2.6 3 0.7 4.6 1.1 116 11 124 255 2.6 0 2.8 2.6 10/11/2005 05:20:00 4.2 0.9 6.1 1.5 4 0.9 6.1 1.1 2.8 0.9 4.9 1.1 110 14 109 255 2.4 0 2.8 2.3 10/11/2005 05:30:00 4.2 0.8 6.1 1.9 4 0.8 6.1 2.3 3 0.8 5.7 1.1 100 12 108 255 2.4 0 2.6 2.3 10/11/2005 05:40:00 4.5 0.8 6.5 2.3 4.3 0.9 6.5 2.3 3.2 1 5.7 0.4 104 12 80 255 2.3 0 2.6 2.3 10/11/2005 05:50:00 4.2 0.6 5.7 2.6 4 0.6 5.7 1.9 3.1 0.6 4.6 1.5 106 9 116 255 2.4 0 2.6 2.3 10/11/2005 06:00:00 3.9 0.5 4.9 2.6 3.7 0.5 4.9 2.3 2.6 0.7 4.6 0.7 108 9 118 255 2.3 0 2.6 2.1 10/11/2005 06:10:00 3.9 0.7 5.7 1.9 3.7 0.7 5.7 1.9 2.6 0.7 4.9 0.7 110 12 113 255 2.1 0 2.3 2.1 10/11/2005 06:20:00 4.1 0.9 6.5 1.9 3.8 0.9 6.5 1.1 2.9 0.9 5.7 0.7 112 13 105 255 2.6 0.1 2.8 2.3 10/11/2005 06:30:00 3.5 0.6 4.9 1.5 3.2 0.7 4.6 1.5 2.4 0.7 4.2 0.4 106 12 111 255 2.6 0.1 2.8 2.3 10/11/2005 06:40:00 3.4 0.8 5.3 1.9 3.2 0.8 5.3 1.9 2.3 0.8 4.6 0.4 99 11 95 255 2.3 0 2.6 2.1 10/11/2005 06:50:00 4.1 0.7 5.7 2.3 3.9 0.7 5.7 1.9 2.9 0.7 4.9 0.7 101 8 87 255 2.1 0 2.3 1.8 10/11/2005 07:00:00 3.6 0.5 5.3 1.9 3.5 0.6 5.3 1.9 2.5 0.7 4.2 0.7 97 9 115 255 2.3 0 2.3 2.1 10/11/2005 07:10:00 3.5 0.8 5.7 1.9 3.3 0.7 5.7 1.9 2.3 0.7 4.2 0.7 98 14 99 255 2.2 0 2.3 1.8 10/11/2005 07:20:00 4.5 0.8 6.1 3 4.3 0.8 6.1 2.3 3.2 0.8 4.9 1.1 102 12 95 255 2.3 0.2 2.6 2.1 10/11/2005 07:30:00 4.9 0.9 6.8 2.6 4.7 0.9 6.8 2.6 3.7 1 6.1 0.7 106 10 110 255 2.7 0 2.8 2.6 10/11/2005 07:40:00 4.8 0.8 6.5 3 4.6 0.7 6.5 2.6 3.5 1 6.5 0.7 106 14 104 255 3 0 3.3 2.8 10/11/2005 07:50:00 4.8 0.9 6.8 1.5 4.6 0.9 6.8 1.5 3.7 0.9 5.7 1.1 106 13 95 255 3.2 0 3.3 3 10/11/2005 08:00:00 4.7 0.9 6.8 2.6 4.5 0.9 6.5 1.9 3.5 0.9 5.3 1.5 102 13 88 255 3.4 0.1 3.8 3 10/11/2005 08:10:00 5 1 7.2 2.6 4.8 1 6.8 2.3 3.8 1.1 6.5 1.1 94 15 108 255 3.8 0 4 3.5 10/11/2005 08:20:00 3.7 0.8 5.7 1.9 3.5 0.9 5.7 1.5 2.8 1 5.3 0.7 89 12 85 255 4.3 0 4.5 4 10/11/2005 08:30:00 4.4 0.8 6.5 2.3 4.1 0.9 6.5 1.9 3.3 0.9 5.7 0.7 90 12 94 255 4.1 0 4.3 4 10/11/2005 08:40:00 4 1 6.5 1.5 3.7 1 6.5 0.7 3.3 1 5.7 0.4 88 17 97 255 4.7 0.3 5.2 4.3 10/11/2005 08:50:00 3.8 1 6.1 1.9 3.4 1 6.1 1.1 3 0.8 5.3 1.1 80 16 88 255 5.1 0 5.2 4.8 10/11/2005 09:00:00 3.7 1 5.7 1.1 3.4 1.1 5.7 0.7 2.9 1 5.3 0.4 88 16 74 255 5.1 0.2 5.5 4.8 10/11/2005 09:10:00 3.5 1 5.7 1.5 3.2 1 5.7 1.1 2.8 1 4.9 0.4 92 13 93 255 5.5 0 5.7 5.5 10/11/2005 09:20:00 3 0.8 4.9 0.7 2.5 1 4.6 0.4 2.2 1 4.6 0.4 87 15 106 255 5.6 0.1 5.7 5.2 10/11/2005 09:30:00 3 0.8 4.9 0.4 2.6 0.9 4.6 0.4 2.2 0.9 4.6 0.4 86 17 105 255 5.9 0 6.2 5.7 10/11/2005 09:40:00 3.2 0.9 5.3 0.4 2.9 1 4.9 0.4 2.6 0.8 4.9 0.4 96 13 102 255 6.4 0 6.7 6.2 10/11/2005 09:50:00 3.5 1 6.1 0.7 3.2 1 5.7 0.7 3 1 6.5 0.4 92 17 93 255 6.4 0.2 6.7 6 10/11/2005 10:00:00 3.5 1 5.7 1.5 3.3 1 5.3 1.5 2.7 1 4.9 0.4 89 15 87 255 6.1 0 6.2 6 10/11/2005 10:10:00 4.1 1.3 7.2 1.5 4 1.2 7.2 1.1 3.5 1.4 6.8 0.7 96 17 100 255 6.7 0.1 7 6.2 10/11/2005 10:20:00 1.5 0.7 3 0.4 1.5 0.7 3.4 0.4 1.2 0.6 3 0.4 93 26 96 255 7.3 0.1 7.8 7 10/11/2005 10:30:00 2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.6 0.9 3.8 0.4 60 29 64 255 7.6 0.1 7.8 7.3 10/11/2005 10:40:00 2.1 0.7 4.2 0.4 2 0.7 4.2 0.4 1.5 0.8 3.8 0.4 61 19 54 255 7.2 0 7.3 7 10/11/2005 10:50:00 3.8 0.8 5.3 1.9 3.8 0.8 5.3 1.9 3.3 0.8 5.3 1.1 68 22 51 255 7.1 0 7.3 7 10/11/2005 11:00:00 2.6 0.8 4.6 0.7 2.6 0.7 4.2 0.7 2 0.8 3.4 0.4 61 24 83 255 7.3 0 7.5 7.3 10/11/2005 11:10:00 1.1 0.8 3 0.4 1.2 0.7 3 0.4 0.8 0.5 3 0.4 24 51 27 255 8 0.1 8.5 7.5 10/11/2005 11:20:00 1.3 0.7 3 0.4 1.4 0.7 3 0.4 0.8 0.6 2.6 0.4 33 41 108 255 7.9 0.2 8.5 7.5 10/11/2005 11:30:00 3.9 1.3 7.2 1.5 4.1 1.3 7.2 1.1 3.3 1.3 6.8 0.4 74 26 84 255 8.3 0.1 8.5 8 10/11/2005 11:40:00 3.9 1 6.5 1.1 3.9 1 6.5 0.7 3.3 1 5.7 0.7 79 22 23 255 8.1 0 8.3 8 10/11/2005 11:50:00 3.6 0.9 6.1 1.1 3.6 0.9 6.1 1.1 3.1 0.9 5.3 1.5 72 27 77 255 8.2 0 8.5 8 10/11/2005 12:00:00 3.8 1.7 7.6 0.4 3.9 1.7 8.4 1.1 3.5 1.7 8 0.4 96 20 108 255 8.4 0.2 8.8 8.3 10/11/2005 12:10:00 5 1.2 8.4 1.5 5.1 1.1 8.4 1.9 4.4 1.2 7.2 0.4 103 17 97 255 8.9 0.1 9.3 8.8 10/11/2005 12:20:00 4.1 1.5 7.2 0.4 4.2 1.3 7.2 1.1 3.4 1.3 6.8 0.7 100 24 103 255 9.4 0.1 9.6 9 10/11/2005 12:30:00 5.3 1.3 8.4 1.9 5.4 1.2 8.4 3 4.7 1.3 8 0.4 98 20 104 255 9.2 0.2 9.6 9 10/11/2005 12:40:00 5 1.2 8 1.9 5.1 1.2 8.8 2.3 4.2 1.2 7.6 1.5 103 20 93 255 9 0 9 8.8 10/11/2005 12:50:00 4.5 1.3 8.8 1.9 4.5 1.3 8.8 2.3 4 1.2 6.8 1.5 98 21 122 255 9.1 0 9.3 9 10/11/2005 13:00:00 4.2 1.3 7.2 1.5 4.2 1.2 7.2 1.5 3.8 1.2 7.2 1.1 82 17 101 255 9.3 0 9.3 9 10/11/2005 13:10:00 2.5 1 4.6 0.4 2.6 0.9 4.6 0.7 2.2 1 4.2 0.4 87 29 101 255 9.6 0.1 9.8 9.3 10/11/2005 13:20:00 2 0.7 3.8 0.4 2.3 0.6 3.8 0.7 1.8 0.8 3.8 0.4 56 27 35 255 9.9 0 10.1 9.6 10/11/2005 13:30:00 2.3 0.6 4.2 0.7 2.5 0.5 4.2 1.1 1.9 0.7 3.8 0.4 12 20 20 255 10.3 0.2 10.9 10.1 10/11/2005 13:40:00 2.5 0.7 4.2 0.4 2.7 0.6 4.2 1.1 2 0.6 4.2 0.4 17 17 2 255 10.7 0 11.1 10.6 10/11/2005 13:50:00 2.1 0.9 4.2 0.4 2.4 0.8 4.2 0.4 2 0.7 3.8 0.4 31 20 35 255 10.7 0.2 11.1 10.6 10/11/2005 14:00:00 2.3 0.7 3.8 0.4 2.5 0.6 3.8 1.1 1.9 0.7 3.8 0.4 44 15 26 255 10.5 0 10.6 10.3 10/11/2005 14:10:00 1.5 0.8 3 0.4 1.8 0.7 3.4 0.4 1.3 0.6 2.6 0.4 34 32 36 255 10.3 0 10.6 10.3 10/11/2005 14:20:00 1.9 0.9 3.8 0.4 2.2 0.8 3.8 0.4 1.6 0.8 3.4 0.4 2 12 12 255 10.3 0.3 10.6 9.6 10/11/2005 14:30:00 1.5 0.8 3 0.4 1.9 0.6 3.4 0.4 1.2 0.7 3 0.4 346 15 345 255 9.2 0.2 9.8 9 10/11/2005 14:40:00 1.3 0.7 2.6 0.4 1.7 0.6 3 0.7 1 0.6 2.6 0.4 3 12 351 255 8.7 0.1 9 8.5 10/11/2005 14:50:00 1.7 0.5 3 0.4 1.9 0.5 3 0.7 1.3 0.6 2.6 0.4 10 12 7 255 8.4 0 8.5 8.5 10/11/2005 15:00:00 1.4 0.6 3 0.4 1.8 0.4 3 0.7 1.1 0.5 2.3 0.4 37 11 52 255 8.3 0 8.5 8.3 10/11/2005 15:10:00 1.4 0.6 2.6 0.4 1.8 0.6 3 0.4 1.2 0.6 2.6 0.4 47 9 55 255 8.1 0.1 8.5 8 10/11/2005 15:20:00 1.5 0.6 3 0.4 1.7 0.5 2.6 0.7 1 0.6 2.6 0.4 10 23 354 255 8.1 0 8.3 8 10/11/2005 15:30:00 0.5 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 16 11 347 255 8.1 0 8.3 8 10/11/2005 15:40:00 0.7 0.5 1.9 0.4 0.9 0.6 2.3 0.4 0.6 0.4 1.5 0.4 42 9 46 255 8 0 8.3 7.8 10/11/2005 15:50:00 1.5 0.7 2.6 0.4 1.6 0.6 2.6 0.4 1 0.6 1.9 0.4 11 13 8 255 8 0 8 7.8 10/11/2005 16:00:00 1.5 0.5 2.3 0.4 1.5 0.5 2.3 0.4 0.9 0.5 1.9 0.4 12 8 12 255 8 0 8 7.8 10/11/2005 16:10:00 1.6 0.4 2.6 0.7 1.7 0.3 2.6 0.7 1 0.5 2.3 0.4 24 19 5 255 7.9 0 8 7.8 10/11/2005 16:20:00 1.6 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 35 13 49 255 7.8 0 8 7.8 10/11/2005 16:30:00 1.6 0.6 3 0.4 1.7 0.6 3 0.4 1.1 0.7 2.6 0.4 25 13 51 255 7.6 0 7.8 7.5 10/11/2005 16:40:00 1.9 0.4 3.4 0.7 1.9 0.4 2.6 1.1 1.4 0.5 2.6 0.4 56 11 62 255 7.4 0 7.5 7.3 10/11/2005 16:50:00 1.9 0.3 2.6 0.4 1.9 0.3 2.6 0.4 1.5 0.4 2.3 0.4 42 8 37 255 7.3 0 7.3 7.3 10/11/2005 17:00:00 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.3 0.5 2.3 0.4 49 9 42 255 7.1 0 7.3 7 10/11/2005 17:10:00 1.7 0.3 2.6 1.1 1.7 0.3 2.6 1.1 0.9 0.4 1.9 0.4 50 8 42 255 6.8 0 7 6.7 10/11/2005 17:20:00 2.1 0.4 2.6 1.1 2.1 0.4 3 1.1 1.5 0.4 2.3 0.4 39 9 32 255 6.6 0 6.7 6.2 10/11/2005 17:30:00 2.2 0.5 3.4 1.1 2.2 0.5 3.4 1.5 1.5 0.6 2.6 0.4 39 8 44 255 6.3 0 6.5 6 10/11/2005 17:40:00 1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.4 0.2 1.1 0.4 38 6 40 255 5.5 0.3 6.2 5 10/11/2005 17:50:00 1.1 0.3 1.9 0.4 1.3 0.3 2.3 0.7 0.5 0.2 1.5 0.4 25 5 25 255 4.6 0.2 5 4.3 10/11/2005 18:00:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 24 0 24 255 4.1 0 4.3 4 10/11/2005 18:10:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 24 0 255 255 3.8 0.1 4 3.5 10/11/2005 18:20:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 42 10 255 255 3.3 0.1 3.5 3 10/11/2005 18:30:00 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 48 0 255 255 2.9 0 3.5 2.6 10/11/2005 18:40:00 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 54 10 255 255 2.4 0 2.6 2.3 10/11/2005 18:50:00 1.2 0.8 2.3 0.4 1.8 0.4 2.6 0.7 1.1 0.4 1.9 0.4 73 7 75 255 2.1 0.1 2.3 1.8 10/11/2005 19:00:00 1.9 0.3 2.6 1.5 2 0.3 2.6 1.5 1.1 0.3 1.9 0.4 74 6 76 255 1.8 0 2.3 1.6 10/11/2005 19:10:00 1.8 0.4 2.6 0.7 1.8 0.4 3 0.7 0.9 0.4 1.9 0.4 67 8 51 255 1.6 0 2.3 1.4 10/11/2005 19:20:00 2.1 0.4 3 1.5 2.1 0.4 3 1.1 1.2 0.4 2.3 0.4 72 11 51 255 1.3 0 1.8 1.1 10/11/2005 19:30:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 1.1 0.7 0.4 1.5 0.4 92 9 79 255 0.9 0.1 1.4 0.7 10/11/2005 19:40:00 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 82 9 90 255 0.9 0.1 1.4 0.9 10/11/2005 19:50:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 0.8 0.4 1.9 0.4 75 9 66 255 0.8 0.1 1.4 0.7 10/11/2005 20:00:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 0.8 0.5 1.9 0.4 97 14 74 255 0.6 0.1 1.1 0.4 10/11/2005 20:10:00 2 0.4 3 1.1 2 0.4 3 1.1 0.6 0.4 1.9 0.4 96 9 112 255 0.3 0.1 0.9 0.2 10/11/2005 20:20:00 2.2 0.4 3 1.1 2.1 0.5 3 0.7 0.8 0.4 1.9 0.4 87 9 91 255 0.2 0 0.4 0.2 10/11/2005 20:30:00 1.8 0.3 2.3 1.1 1.7 0.3 2.6 0.7 0.7 0.3 1.9 0.4 76 10 83 255 0.2 0 0.4 0.2 10/11/2005 20:40:00 1.5 0.4 2.6 0.4 1.4 0.5 2.6 0.4 0.4 0.2 2.3 0.4 65 7 58 255 0.1 0 0.4 -0.1 10/11/2005 20:50:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 0.6 0.3 1.5 0.4 74 8 78 255 0 0 0.2 -0.1 10/11/2005 21:00:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 76 8 65 255 0.1 0 0.4 -0.1 10/11/2005 21:10:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.2 1.1 0.4 69 9 80 255 0.1 0 0.2 -0.1 10/11/2005 21:20:00 2 0.3 3 1.1 1.9 0.3 3 1.1 0.8 0.3 1.5 0.4 81 11 86 255 -0.1 0 0.2 -0.1 10/11/2005 21:30:00 2 0.3 2.6 1.5 1.8 0.4 2.6 1.1 0.7 0.4 1.9 0.4 91 9 95 255 0 0 0.2 -0.1 10/11/2005 21:40:00 2.1 0.5 3.8 1.1 2 0.5 3.8 0.7 1.1 0.7 3 0.4 80 15 82 255 0.1 0 0.2 -0.1 10/11/2005 21:50:00 2.5 0.3 3.4 1.5 2.4 0.3 3.4 1.5 1.4 0.4 2.3 0.7 78 9 91 255 0.2 0 0.4 0.2 10/11/2005 22:00:00 2 0.5 3.8 0.7 1.9 0.5 3.8 1.1 0.8 0.5 2.3 0.4 80 9 62 255 0.2 0 0.4 0.2 10/11/2005 22:10:00 2.1 0.5 3 1.1 1.9 0.5 3 0.7 0.8 0.4 1.5 0.4 83 7 77 255 0.2 0 0.4 0.2 10/11/2005 22:20:00 2.1 0.3 3 1.5 1.9 0.3 2.6 1.1 0.7 0.4 1.9 0.4 100 11 106 255 0.4 0 0.7 0.2 10/11/2005 22:30:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.1 0.5 2.6 0.4 115 10 107 255 0.3 0 0.7 0.2 10/11/2005 22:40:00 2 0.6 3.4 0.4 1.8 0.6 3 0.4 0.9 0.4 2.3 0.4 119 12 109 255 0.2 0 0.4 0.2 10/11/2005 22:50:00 2.3 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.3 0.5 2.6 0.4 124 12 113 255 0.1 0 0.4 -0.1 10/11/2005 23:00:00 2.3 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.3 0.6 2.6 0.4 126 9 124 255 0.5 0 0.7 0.2 10/11/2005 23:10:00 2.2 0.5 3 1.1 2 0.6 3 0.7 1.2 0.5 2.3 0.4 130 12 114 255 0.5 0.1 0.7 0.2 10/11/2005 23:20:00 1.7 0.8 3.4 0.4 1.4 0.9 3.4 0.4 0.9 0.6 3 0.4 119 13 90 255 0.1 0 0.4 -0.1 10/11/2005 23:30:00 2.6 0.6 3.4 1.1 2.3 0.7 3.4 0.4 1.1 0.5 2.6 0.4 100 8 104 255 -0.2 0.1 0.2 -0.5 10/11/2005 23:40:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.5 0.5 3 0.4 108 8 110 255 -0.6 0 -0.5 -0.7 10/11/2005 23:50:00 2.7 0.6 3.8 0.7 2.6 0.6 3.8 0.7 1.3 0.7 3 0.4 115 10 112 255 -0.9 0.1 -0.5 -1 10/12/2005 00:00:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 0.7 0.9 0.5 2.3 0.4 118 12 109 255 -0.8 0 -0.5 -0.7 10/12/2005 00:10:00 2.1 0.5 3.4 1.1 1.9 0.5 3.4 0.7 0.7 0.5 2.3 0.4 115 8 118 255 -0.5 0 -0.5 -0.7 10/12/2005 00:20:00 2.3 0.4 3.4 1.5 2.1 0.5 3 0.7 1 0.5 2.3 0.4 114 8 118 255 -0.5 0 -0.5 -0.5 10/12/2005 00:30:00 2 0.4 3 1.1 1.7 0.6 3 0.4 0.6 0.3 1.9 0.4 119 9 108 255 -0.5 0 -0.5 -0.5 10/12/2005 00:40:00 2.7 0.5 3.8 1.1 2.5 0.5 3.4 1.1 1.4 0.5 2.6 0.4 118 8 124 255 -0.5 0 -0.5 -0.5 10/12/2005 00:50:00 2.4 0.6 3.8 1.1 2.1 0.7 3.4 0.4 1.2 0.5 2.6 0.4 122 12 136 255 -0.6 0 -0.5 -0.7 10/12/2005 01:00:00 2.4 0.5 3.4 1.1 2 0.5 3.4 0.4 1.3 0.5 2.6 0.4 130 13 124 255 -0.6 0 -0.5 -0.7 10/12/2005 01:10:00 2.8 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.9 0.5 3 0.7 133 11 134 255 -0.5 0 -0.3 -0.5 10/12/2005 01:20:00 2.7 0.6 4.2 1.1 2.5 0.6 3.8 1.1 1.5 0.6 3 0.4 129 12 131 255 -0.4 0 -0.3 -0.5 10/12/2005 01:30:00 2.7 0.5 4.2 1.5 2.4 0.6 4.2 1.1 1.2 0.6 3.4 0.4 119 12 120 255 -0.6 0 -0.5 -0.7 10/12/2005 01:40:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1 0.5 3 0.4 115 12 111 255 -0.5 0 -0.5 -0.5 10/12/2005 01:50:00 2.2 0.5 3.8 0.7 2 0.5 3.8 0.7 0.8 0.5 2.6 0.4 119 11 127 255 -0.6 0 -0.5 -0.5 10/12/2005 02:00:00 2.3 0.5 3.4 1.1 2 0.5 3.4 0.4 0.9 0.5 1.9 0.4 118 13 124 255 -0.5 0 -0.3 -0.5 10/12/2005 02:10:00 2.3 0.5 3.4 0.4 2 0.6 3 0.4 0.9 0.6 2.6 0.4 117 13 129 255 -0.3 0 -0.1 -0.5 10/12/2005 02:20:00 2.4 0.6 3.8 0.4 2.2 0.6 3.8 0.4 1.1 0.6 2.3 0.4 115 13 97 255 0.2 0.1 0.7 -0.1 10/12/2005 02:30:00 2 0.7 3.8 0.4 1.8 0.6 3.4 0.4 0.8 0.5 2.3 0.4 112 15 121 255 0.8 0.1 1.1 0.7 10/12/2005 02:40:00 2.7 0.4 3.8 0.7 2.4 0.5 3.8 0.7 1.4 0.6 3 0.4 111 9 111 255 1.3 0.1 1.6 0.9 10/12/2005 02:50:00 2.3 0.7 3.8 0.4 2 0.9 3.4 0.4 1.1 0.7 2.6 0.4 113 9 101 255 1.3 0 1.4 1.4 10/12/2005 03:00:00 2 0.5 3 0.4 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 117 10 111 255 1.2 0 1.4 0.9 10/12/2005 03:10:00 2.2 0.5 3.8 0.7 2 0.6 3.4 0.7 1.2 0.5 2.6 0.4 129 13 117 255 1.3 0 1.6 1.1 10/12/2005 03:20:00 2.6 0.6 3.8 1.1 2.3 0.6 3.8 0.4 1.4 0.6 3 0.4 118 15 117 255 1.6 0 1.8 1.4 10/12/2005 03:30:00 3.2 0.6 4.6 1.5 2.9 0.6 4.2 0.7 2.2 0.7 3.8 0.7 114 12 105 255 1.9 0 2.1 1.8 10/12/2005 03:40:00 3.1 0.6 4.6 1.5 2.9 0.6 4.6 1.1 2.1 0.7 3.8 0.4 116 11 104 255 2.1 0 2.3 2.1 10/12/2005 03:50:00 2.3 0.8 4.2 0.4 2 0.8 3.8 0.4 1.3 0.7 3.4 0.4 116 18 115 255 2.3 0 2.3 2.1 10/12/2005 04:00:00 2.3 0.7 4.2 0.4 2 0.7 4.2 0.4 1.2 0.7 3.4 0.4 114 21 101 255 2.2 0 2.3 2.1 10/12/2005 04:10:00 1.9 0.6 3.4 0.4 1.6 0.7 3.4 0.4 0.9 0.6 2.6 0.4 114 17 112 255 2.3 0 2.3 2.1 10/12/2005 04:20:00 1.9 0.6 3.4 0.4 1.4 0.7 3.4 0.4 0.9 0.6 2.3 0.4 115 20 115 255 2.3 0 2.3 2.3 10/12/2005 04:30:00 2 0.6 3.8 0.4 1.5 0.7 3.4 0.4 0.9 0.6 3 0.4 123 15 110 255 2.3 0 2.3 2.3 10/12/2005 04:40:00 2 0.6 3.4 0.4 1.5 0.7 3.4 0.4 1.1 0.5 2.6 0.4 121 20 124 255 2.2 0 2.3 2.1 10/12/2005 04:50:00 1.8 0.8 3.8 0.4 1.4 0.8 3 0.4 0.8 0.5 2.3 0.4 106 20 84 255 2.1 0 2.3 1.8 10/12/2005 05:00:00 2.4 0.6 4.2 1.1 2 0.7 3.8 0.4 1.2 0.6 3 0.4 113 19 105 255 2.1 0 2.3 1.8 10/12/2005 05:10:00 2.7 0.8 5.3 1.1 2.4 0.8 4.9 0.7 1.4 0.8 4.2 0.4 114 18 94 255 2.3 0 2.6 2.3 10/12/2005 05:20:00 2.4 1 4.6 0.4 2.2 1 4.6 0.4 1.6 0.9 3.8 0.4 105 18 96 255 2.4 0 2.6 2.3 10/12/2005 05:30:00 1.6 0.7 3.4 0.4 1.2 0.7 3 0.4 0.7 0.6 3 0.4 112 18 123 255 2.4 0 2.6 2.3 10/12/2005 05:40:00 1.4 0.6 3 0.4 0.9 0.6 2.6 0.4 0.7 0.4 3 0.4 64 32 93 255 2.4 0 2.6 2.3 10/12/2005 05:50:00 1 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 33 18 27 255 2.3 0 2.6 2.3 10/12/2005 06:00:00 2.4 0.9 4.6 0.4 2 1.1 4.6 0.4 1.5 1 3.4 0.4 85 21 63 255 2.3 0 2.6 1.8 10/12/2005 06:10:00 1.6 0.8 3 0.4 1.1 0.7 2.6 0.4 0.6 0.4 1.9 0.4 99 20 88 255 1.8 0 2.1 1.6 10/12/2005 06:20:00 2.7 0.7 4.2 0.7 2.3 0.7 3.8 0.4 1.3 0.7 3 0.4 103 13 91 255 1.7 0 1.8 1.6 10/12/2005 06:30:00 3.1 0.6 4.2 1.5 2.8 0.7 4.2 0.7 1.7 0.7 3 0.4 105 13 113 255 1.8 0 1.8 1.6 10/12/2005 06:40:00 3 0.5 4.2 1.5 2.7 0.5 3.8 1.1 1.4 0.6 3 0.4 110 15 90 255 1.8 0 1.8 1.6 10/12/2005 06:50:00 2.8 0.4 3.8 1.5 2.4 0.5 3.4 0.4 1.4 0.6 2.6 0.4 105 9 109 255 1.8 0 1.8 1.8 10/12/2005 07:00:00 2.5 0.6 3.4 0.7 2 0.7 3.4 0.4 1 0.6 2.6 0.4 115 15 90 255 1.8 0 2.1 1.8 10/12/2005 07:10:00 2 0.5 3.4 0.7 1.4 0.6 3 0.4 0.9 0.4 2.3 0.4 124 13 124 255 1.8 0 1.8 1.8 10/12/2005 07:20:00 2.3 0.5 3.4 1.5 1.6 0.6 3 0.4 0.8 0.5 2.3 0.4 121 14 133 255 1.8 0 1.8 1.8 10/12/2005 07:30:00 1.2 1 3.8 0.4 0.9 0.8 3.4 0.4 0.5 0.4 2.6 0.4 158 53 108 255 1.8 0 1.8 1.8 10/12/2005 07:40:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 263 94 325 255 1.8 0 1.8 1.8 10/12/2005 07:50:00 0.9 0.5 2.3 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 268 122 101 255 1.8 0 1.8 1.6 10/12/2005 08:00:00 1 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.4 0.2 1.5 0.4 107 16 119 255 1.7 0 1.8 1.6 10/12/2005 08:10:00 1.6 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 2.3 0.4 138 21 99 255 1.7 0 1.8 1.6 10/12/2005 08:20:00 1.9 0.5 3 0.4 1.3 0.6 2.6 0.4 0.9 0.6 2.3 0.4 150 17 153 255 1.8 0 1.8 1.8 10/12/2005 08:30:00 2.4 0.7 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.8 3.8 0.4 147 9 151 255 1.8 0 1.8 1.8 10/12/2005 08:40:00 3.2 0.6 4.9 1.9 2.9 0.7 4.6 1.5 2.4 0.6 4.2 0.7 131 11 133 255 1.9 0.1 2.1 1.8 10/12/2005 08:50:00 3.2 0.6 4.6 1.5 3 0.6 4.6 1.5 2.4 0.7 3.8 0.7 134 15 142 255 2.1 0 2.3 2.1 10/12/2005 09:00:00 3.1 0.6 4.2 1.9 2.8 0.6 4.2 1.1 2.4 0.6 3.8 0.7 132 10 134 255 2.2 0 2.3 2.1 10/12/2005 09:10:00 2.7 0.4 3.8 1.5 2.4 0.5 3.8 0.7 1.9 0.5 3 0.7 135 11 122 255 2.3 0 2.3 2.3 10/12/2005 09:20:00 2 0.6 3.8 0.4 1.5 0.7 3.4 0.4 1 0.6 3 0.4 133 18 143 255 2.2 0 2.3 2.1 10/12/2005 09:30:00 1.4 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 146 20 121 255 2.3 0 2.6 2.3 10/12/2005 09:40:00 1.9 0.4 2.6 0.7 1.3 0.5 2.3 0.4 0.9 0.6 2.6 0.4 151 9 144 255 2.4 0 2.6 2.3 10/12/2005 09:50:00 2.1 0.4 3 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.6 0.4 152 12 142 255 2.4 0 2.6 2.3 10/12/2005 10:00:00 1.6 0.5 2.6 0.4 1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 146 9 138 255 2.4 0 2.6 2.3 10/12/2005 10:10:00 1.6 0.4 2.6 0.4 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 143 9 98 255 2.5 0 2.6 2.3 10/12/2005 10:20:00 0.9 0.6 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 138 7 121 255 2.6 0 2.8 2.6 10/12/2005 10:30:00 0.9 0.5 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 119 12 140 255 2.8 0 2.8 2.6 10/12/2005 10:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 115 255 2.9 0 3.3 2.8 10/12/2005 10:50:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 139 28 171 255 3.1 0 3.3 3 10/12/2005 11:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 0 171 255 3.2 0 3.5 3.3 10/12/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 0 255 255 3.4 0 3.5 3.3 10/12/2005 11:20:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 167 10 171 255 3.5 0 3.5 3.5 10/12/2005 11:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 142 255 3.6 0 3.8 3.5 10/12/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 255 255 3.8 0 4 3.5 10/12/2005 11:50:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 119 41 55 255 4 0 4.3 3.8 10/12/2005 12:00:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 12 0 12 255 4 0 4 4 10/12/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 0 255 255 4 0 4 4 10/12/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 0 255 255 4 0 4 4 10/12/2005 12:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 76 325 255 4 0 4.3 4 10/12/2005 12:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 0 202 255 4.3 0 4.5 4 10/12/2005 12:50:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 210 8 219 255 4.8 0.1 5 4.5 10/12/2005 13:00:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 276 53 187 255 5.2 0.1 5.5 5 10/12/2005 13:10:00 0.8 0.6 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 259 33 290 255 5.4 0 5.5 5.2 10/12/2005 13:20:00 2.2 0.8 3.8 0.7 1.7 1 3.8 0.4 1.3 0.8 4.2 0.4 301 22 277 255 5.6 0 5.7 5.5 10/12/2005 13:30:00 1.7 0.4 2.3 0.7 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 350 12 347 255 5.6 0 5.7 5.7 10/12/2005 13:40:00 0.8 0.5 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 341 4 356 255 5.7 0 5.7 5.7 10/12/2005 13:50:00 1.5 0.9 4.2 0.4 1 0.9 3.8 0.4 0.9 0.7 3 0.4 290 41 260 255 6 0 6.2 5.7 10/12/2005 14:00:00 2.2 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3.4 0.4 283 28 291 255 6.2 0 6.2 6 10/12/2005 14:10:00 2.6 1 4.6 0.4 2.1 1.1 4.6 0.4 1.7 1.2 4.9 0.4 259 22 269 255 6.4 0 6.7 6.2 10/12/2005 14:20:00 2.7 1 4.9 0.4 2.2 1.1 4.2 0.4 1.8 1 4.6 0.4 291 22 311 255 6.7 0 6.7 6.2 10/12/2005 14:30:00 2.8 0.7 4.2 0.7 2.4 0.8 4.2 0.4 2 0.7 3.8 0.4 303 23 308 255 6.3 0.1 6.7 6.2 10/12/2005 14:40:00 2.6 1.1 4.6 0.4 2.2 1.2 4.2 0.4 1.9 1.2 4.2 0.4 319 21 307 255 6.2 0 6.2 6 10/12/2005 14:50:00 2.8 0.9 5.3 0.4 2.4 1 5.3 0.4 2.1 1.1 5.3 0.4 304 20 304 255 6.7 0.3 7.3 6.2 10/12/2005 15:00:00 3.3 0.8 4.9 1.5 2.9 0.9 4.9 1.1 2.5 1 4.9 0.4 301 19 291 255 6.3 0.1 6.7 6 10/12/2005 15:10:00 2.9 0.7 4.6 1.5 2.6 0.7 4.2 0.7 2 0.8 4.2 0.4 303 17 315 255 5.9 0 6 5.7 10/12/2005 15:20:00 2.9 0.7 4.6 0.7 2.4 0.8 4.2 0.4 1.9 0.8 3.8 0.4 314 18 302 255 5.7 0 5.7 5.7 10/12/2005 15:30:00 3.2 0.6 4.6 1.9 2.9 0.6 4.2 1.1 2.6 0.9 4.2 0.4 298 13 296 255 5.6 0 5.7 5.5 10/12/2005 15:40:00 3.1 0.7 4.9 1.1 2.8 0.9 4.9 0.7 2.4 0.8 4.2 0.4 300 16 290 255 5.7 0 6 5.7 10/12/2005 15:50:00 2.8 0.7 4.6 1.1 2.4 0.8 4.2 0.4 2.2 0.9 4.2 0.4 289 17 296 255 5.6 0 5.7 5.5 10/12/2005 16:00:00 2.7 0.7 4.2 0.7 2.3 0.7 4.2 0.4 1.8 0.9 3.8 0.4 297 19 295 255 5.4 0 5.7 5.5 10/12/2005 16:10:00 2.9 0.7 4.6 1.1 2.5 0.8 4.2 0.4 2.1 0.9 3.8 0.4 292 16 287 255 5.1 0 5.5 5 10/12/2005 16:20:00 2.6 0.7 4.2 0.7 2.3 0.8 4.2 0.4 1.7 0.8 3.8 0.4 286 12 294 255 4.7 0.1 5 4.5 10/12/2005 16:30:00 2.5 0.8 4.6 0.7 2.1 0.9 4.2 0.4 1.6 0.8 3.8 0.4 280 16 281 255 4.4 0 4.5 4.3 10/12/2005 16:40:00 2.1 0.8 3.8 0.4 1.6 0.9 3.4 0.4 1.1 0.7 3 0.4 279 18 286 255 4.1 0 4.3 4 10/12/2005 16:50:00 1.8 0.8 3.8 0.4 1.3 0.9 3.4 0.4 0.9 0.7 3.8 0.4 269 14 276 255 4 0 4 3.8 10/12/2005 17:00:00 2.2 0.5 3.4 1.1 1.7 0.6 3.4 0.4 1 0.7 3 0.4 273 15 280 255 3.6 0 3.8 3.5 10/12/2005 17:10:00 2.4 0.8 4.2 0.4 1.9 0.9 4.2 0.4 1.1 0.7 3 0.4 266 13 273 255 3.5 0 3.5 3.5 10/12/2005 17:20:00 2.3 0.7 4.2 0.7 1.9 0.8 3.8 0.4 1.2 0.7 3 0.4 272 18 281 255 3.4 0 3.5 3.3 10/12/2005 17:30:00 2 0.6 3.4 0.4 1.5 0.7 3.4 0.4 0.8 0.5 2.6 0.4 268 17 274 255 3.4 0 3.5 3.5 10/12/2005 17:40:00 2.1 0.6 3.8 0.4 1.7 0.7 3.4 0.4 0.8 0.6 2.3 0.4 269 14 271 255 3.5 0 3.5 3.5 10/12/2005 17:50:00 1.8 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.5 2.3 0.4 265 13 244 255 3.4 0 3.8 3.3 10/12/2005 18:00:00 1.6 0.6 3 0.4 1.1 0.6 2.6 0.4 0.5 0.3 1.5 0.4 269 14 273 255 3.3 0 3.5 3.3 10/12/2005 18:10:00 1.7 0.6 3 0.4 1.2 0.7 3 0.4 0.7 0.5 2.6 0.4 275 17 272 255 3.2 0 3.5 3 10/12/2005 18:20:00 2.2 0.6 3.8 0.7 1.8 0.7 3.8 0.4 1 0.6 2.6 0.4 269 13 255 255 3.1 0 3.3 3 10/12/2005 18:30:00 1.9 0.5 3 0.7 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 263 12 252 255 3.2 0 3.5 3 10/12/2005 18:40:00 1.6 0.7 3 0.4 1.1 0.7 2.6 0.4 0.6 0.5 2.3 0.4 259 15 235 255 3.2 0 3.8 3 10/12/2005 18:50:00 1.7 0.5 3 0.4 1 0.6 2.3 0.4 0.5 0.4 2.3 0.4 248 14 252 255 3.2 0 3.8 3.3 10/12/2005 19:00:00 1.6 0.4 2.6 0.7 1.1 0.5 2.6 0.4 0.5 0.3 1.9 0.4 247 15 246 255 3 0.1 3.3 2.8 10/12/2005 19:10:00 1.5 0.5 3 0.4 1 0.5 2.6 0.4 0.5 0.3 1.5 0.4 245 13 244 255 2.8 0 3.3 2.6 10/12/2005 19:20:00 0.9 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 265 24 291 255 2.5 0.1 3 2.3 10/12/2005 19:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 267 10 294 255 2 0.2 2.3 1.8 10/12/2005 19:40:00 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 263 0 263 255 1.5 0.2 2.3 1.4 10/12/2005 19:50:00 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 265 4 263 255 1.1 0.1 1.6 0.9 10/12/2005 20:00:00 1.1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 263 8 268 255 0.7 0 0.9 0.7 10/12/2005 20:10:00 1.2 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 262 7 265 255 0.5 0 0.9 0.4 10/12/2005 20:20:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 239 6 246 255 0.4 0 0.7 0.2 10/12/2005 20:30:00 1.4 0.3 1.9 0.7 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 230 11 238 255 0.4 0 0.7 0.2 10/12/2005 20:40:00 2 0.2 2.6 1.5 1.5 0.3 2.3 0.7 0.6 0.3 1.5 0.4 209 5 212 255 0.7 0 0.9 0.7 10/12/2005 20:50:00 1.6 0.3 2.3 0.7 1 0.4 2.3 0.4 0.4 0.1 1.1 0.4 212 6 204 255 0.8 0 0.9 0.9 10/12/2005 21:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 216 255 0.9 0 0.9 0.9 10/12/2005 21:10:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 216 0 216 255 0.9 0 0.9 0.9 10/12/2005 21:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 217 255 0.9 0 0.9 0.9 10/12/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.8 0 0.9 0.7 10/12/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.8 0 0.9 0.9 10/12/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.8 0 0.9 0.9 10/12/2005 22:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 217 255 0.9 0 0.9 0.9 10/12/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.8 0 0.9 0.9 10/12/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.9 0 0.9 0.9 10/12/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.9 0 1.1 0.9 10/12/2005 22:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 217 255 0.8 0 0.9 0.7 10/12/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.7 0 0.9 0.7 10/12/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 216 0 255 255 0.4 0.1 0.7 0.2 10/12/2005 23:10:00 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 250 29 277 255 0.1 0 0.2 0.2 10/12/2005 23:20:00 1.9 0.2 2.6 1.1 1.4 0.3 2.3 0.4 0.4 0.2 1.1 0.4 254 5 258 255 0.1 0 0.2 -0.1 10/12/2005 23:30:00 1.8 0.2 2.3 1.1 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 250 12 255 255 -0.2 0 -0.1 -0.3 10/12/2005 23:40:00 1.7 0.2 2.3 1.1 1.1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 256 5 251 255 -0.3 0 -0.1 -0.5 10/12/2005 23:50:00 1.3 0.3 1.9 0.7 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 278 20 267 255 -0.3 0 -0.1 -0.5 10/13/2005 00:00:00 1.2 0.3 1.9 0.7 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 313 2 314 255 -0.3 0 0.2 -0.3 10/13/2005 00:10:00 1.4 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 316 7 309 255 -0.3 0 -0.1 -0.3 10/13/2005 00:20:00 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 304 17 323 255 -0.2 0 -0.1 -0.3 10/13/2005 00:30:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 289 255 -0.2 0 -0.1 -0.3 10/13/2005 00:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 289 255 -0.1 0 -0.1 -0.1 10/13/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 255 255 0 0 0.2 -0.1 10/13/2005 01:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 289 255 0 0 0.2 -0.1 10/13/2005 01:10:00 1.5 0.3 1.9 0.7 0.9 0.4 1.5 0.4 0.6 0.2 1.1 0.4 73 66 104 255 0.1 0 0.2 -0.1 10/13/2005 01:20:00 1.5 0.2 1.9 1.1 0.9 0.3 1.5 0.4 0.4 0.1 0.7 0.4 102 0 102 255 0 0 0.2 -0.1 10/13/2005 01:30:00 1.7 0.2 1.9 1.5 1.2 0.2 1.5 0.4 0.5 0.3 1.5 0.4 103 2 102 255 0.1 0 0.2 -0.1 10/13/2005 01:40:00 0.8 0.5 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 120 2 106 255 0 0 0.2 -0.1 10/13/2005 01:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 121 255 0 0 0.2 -0.1 10/13/2005 02:00:00 1.1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 45 41 20 255 0 0 0.2 -0.1 10/13/2005 02:10:00 1.1 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 12 20 255 0 0 0.2 -0.1 10/13/2005 02:20:00 1.2 0.2 1.9 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 44 0 44 255 -0.1 0 0.2 -0.1 10/13/2005 02:30:00 1.3 0.2 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 44 0 44 255 0 0 0.2 -0.1 10/13/2005 02:40:00 1.5 0.3 2.3 0.7 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 44 0 44 255 0.1 0 0.2 -0.1 10/13/2005 02:50:00 1.4 0.3 2.3 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 37 9 44 255 -0.1 0 0.2 -0.1 10/13/2005 03:00:00 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 24 0 24 255 -0.2 0 -0.1 -0.3 10/13/2005 03:10:00 0.8 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 8 6 24 255 -0.1 0 -0.1 -0.1 10/13/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 255 255 -0.1 0 0.2 -0.1 10/13/2005 03:30:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 309 53 263 255 -0.1 0 0.2 -0.1 10/13/2005 03:40:00 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 254 11 268 255 0 0 0.2 -0.1 10/13/2005 03:50:00 2.5 0.3 3 1.9 2.1 0.4 3 0.7 0.9 0.4 2.3 0.4 268 13 268 255 0 0 0.2 -0.1 10/13/2005 04:00:00 2.4 0.7 3.8 0.7 1.9 0.8 3.8 0.4 0.8 0.7 3 0.4 285 12 308 255 0 0 0.2 -0.1 10/13/2005 04:10:00 3.1 0.5 4.2 1.9 2.7 0.6 3.8 0.7 1.6 0.6 3.4 0.4 303 10 305 255 -0.1 0 0.2 -0.1 10/13/2005 04:20:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 9 17 307 255 0.2 0.1 0.4 -0.1 10/13/2005 04:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 38 26 27 255 0.4 0 0.4 0.2 10/13/2005 04:40:00 0.9 0.5 2.6 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.9 0.4 15 41 335 255 0.2 0 0.4 0.2 10/13/2005 04:50:00 1.2 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 32 5 25 255 0.1 0 0.2 -0.1 10/13/2005 05:00:00 1.6 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.6 0.4 1.9 0.4 28 2 29 255 0 0 0.2 -0.1 10/13/2005 05:10:00 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 23 0 23 255 -0.1 0 0.2 -0.3 10/13/2005 05:20:00 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 357 36 23 255 -0.3 0 -0.1 -0.5 10/13/2005 05:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 308 0 308 255 -0.3 0 -0.3 -0.5 10/13/2005 05:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 308 0 308 255 -0.4 0 -0.3 -0.5 10/13/2005 05:50:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 250 49 210 255 -0.4 0 -0.3 -0.5 10/13/2005 06:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 72 62 255 -0.5 0 -0.5 -0.5 10/13/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 255 255 -0.5 0 -0.5 -0.5 10/13/2005 06:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 36 136 255 -0.5 0 -0.5 -0.5 10/13/2005 06:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 136 255 -0.5 0 -0.5 -0.5 10/13/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 -0.5 0 -0.5 -0.5 10/13/2005 06:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 136 255 -0.5 0 -0.5 -0.5 10/13/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 -0.5 0 -0.5 -0.5 10/13/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 255 255 -0.4 0 -0.3 -0.5 10/13/2005 07:20:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 152 8 143 255 -0.5 0 -0.3 -0.5 10/13/2005 07:30:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 156 0 155 255 -0.5 0 -0.5 -0.5 10/13/2005 07:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 156 255 -0.5 0 -0.5 -0.5 10/13/2005 07:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 90 156 255 -0.5 0 -0.5 -0.5 10/13/2005 08:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 335 255 -0.5 0 -0.5 -0.5 10/13/2005 08:10:00 0.9 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 335 255 -0.5 0 -0.5 -0.5 10/13/2005 08:20:00 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 335 255 -0.3 0 -0.1 -0.5 10/13/2005 08:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 335 255 -0.2 0 -0.1 -0.3 10/13/2005 08:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 335 255 -0.1 0 0.2 -0.3 10/13/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 255 255 0.1 0 0.2 -0.1 10/13/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 255 255 0.4 0 0.7 0.2 10/13/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 335 0 255 255 0.6 0 0.9 0.4 10/13/2005 09:20:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 274 64 206 255 0.9 0 1.4 0.7 10/13/2005 09:30:00 1.2 0.2 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 220 8 225 255 1.4 0 1.6 1.4 10/13/2005 09:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 225 0 225 255 1.7 0 1.8 1.6 10/13/2005 09:50:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 221 5 226 255 1.8 0 1.8 1.8 10/13/2005 10:00:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 230 0 230 255 2 0 2.1 1.8 10/13/2005 10:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 230 0 230 255 2.1 0 2.3 1.8 10/13/2005 10:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 230 0 230 255 2.3 0 2.6 2.3 10/13/2005 10:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 230 0 230 255 2.4 0 2.6 2.3 10/13/2005 10:40:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 243 9 219 255 2.6 0 2.8 2.6 10/13/2005 10:50:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 232 6 226 255 2.7 0 2.8 2.6 10/13/2005 11:00:00 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 230 0 230 255 2.7 0 2.8 2.8 10/13/2005 11:10:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 230 0 230 255 3 0 3.3 2.8 10/13/2005 11:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 230 0 230 255 3.3 0 3.5 3.3 10/13/2005 11:30:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 230 0 230 255 3.5 0 3.5 3.5 10/13/2005 11:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 240 24 230 255 3.5 0 3.5 3.5 10/13/2005 11:50:00 0.7 0.4 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.7 0.4 249 38 258 255 3.6 0 3.8 3.5 10/13/2005 12:00:00 1 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 249 12 253 255 3.6 0 3.8 3.5 10/13/2005 12:10:00 1.1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 196 13 211 255 3.9 0.1 4.3 3.5 10/13/2005 12:20:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.9 0.4 239 17 229 255 4.2 0 4.5 4 10/13/2005 12:30:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 316 41 318 255 4.5 0 4.5 4.3 10/13/2005 12:40:00 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 7 11 347 255 4.5 0 4.8 4.5 10/13/2005 12:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 12 0 12 255 4.6 0 4.8 4.5 10/13/2005 13:00:00 0.7 0.4 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.7 0.4 347 23 343 255 4.9 0 5 4.8 10/13/2005 13:10:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 322 23 293 255 4.9 0 5 4.8 10/13/2005 13:20:00 1.1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 314 3 313 255 4.7 0 4.8 4.8 10/13/2005 13:30:00 1.5 0.4 2.6 0.4 1 0.5 2.3 0.4 0.7 0.3 1.5 0.4 303 12 293 255 4.7 0 4.8 4.8 10/13/2005 13:40:00 1.9 0.4 2.6 1.1 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 297 14 288 255 4.6 0 4.8 4.5 10/13/2005 13:50:00 2 0.4 3 0.7 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 296 11 281 255 4.5 0 4.5 4.3 10/13/2005 14:00:00 2 0.6 3.4 0.7 1.6 0.7 3 0.4 1.3 0.7 3 0.4 288 22 294 255 4.4 0 4.5 4.3 10/13/2005 14:10:00 2.5 0.4 3.4 1.5 2.1 0.5 3 0.7 1.8 0.6 3 0.4 294 14 298 255 4.3 0 4.5 4 10/13/2005 14:20:00 2.3 0.5 3.4 0.4 1.9 0.6 3 0.4 1.8 0.8 3 0.4 284 15 295 255 4 0 4.3 3.8 10/13/2005 14:30:00 1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 290 30 278 255 4 0 4 3.8 10/13/2005 14:40:00 1.1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 301 16 263 255 4 0 4 3.8 10/13/2005 14:50:00 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 302 13 299 255 4 0 4 4 10/13/2005 15:00:00 1.7 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 307 7 301 255 4 0 4 3.8 10/13/2005 15:10:00 1.7 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 310 6 296 255 3.8 0 4 3.8 10/13/2005 15:20:00 1.5 0.3 2.3 0.7 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 312 5 310 255 3.8 0 3.8 3.8 10/13/2005 15:30:00 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 300 8 308 255 3.7 0 3.8 3.5 10/13/2005 15:40:00 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 312 33 19 255 3.7 0 3.8 3.5 10/13/2005 15:50:00 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 357 4 355 255 3.9 0 4 3.8 10/13/2005 16:00:00 1.5 0.2 1.9 0.7 0.8 0.3 1.5 0.4 0.7 0.3 1.1 0.4 355 6 358 255 4 0 4 3.8 10/13/2005 16:10:00 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 329 11 323 255 3.8 0 4 3.8 10/13/2005 16:20:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 353 0 353 255 3.7 0 3.8 3.5 10/13/2005 16:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 353 255 3.6 0 3.8 3.5 10/13/2005 16:40:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 353 0 353 255 3.6 0 3.5 3.5 10/13/2005 16:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 353 255 3.5 0 3.5 3.5 10/13/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 3.4 0 3.5 3.3 10/13/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 3.3 0 3.5 3 10/13/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 3 0 3.3 2.8 10/13/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 2.8 0 2.8 2.8 10/13/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 2.6 0.1 2.8 2.3 10/13/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 255 255 2.2 0 2.8 2.1 10/13/2005 18:00:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 353 255 2 0 2.6 1.8 10/13/2005 18:10:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 353 255 1.8 0 1.8 1.8 10/13/2005 18:20:00 1.2 0.2 1.5 0.7 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 55 8 56 255 1.8 0 1.8 1.8 10/13/2005 18:30:00 1.3 0.2 1.5 0.7 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 56 0 56 255 1.8 0 1.8 1.6 10/13/2005 18:40:00 1.1 0.3 1.9 0.7 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 58 4 58 255 1.7 0 1.8 1.6 10/13/2005 18:50:00 1.3 0.3 1.9 0.7 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 75 3 68 255 1.5 0 1.8 1.4 10/13/2005 19:00:00 1.3 0.2 1.9 0.7 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 51 6 49 255 1.4 0 1.6 1.4 10/13/2005 19:10:00 1.2 0.2 1.9 0.7 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 50 5 49 255 1.2 0 1.4 1.1 10/13/2005 19:20:00 1.7 0.3 2.3 1.1 1.3 0.4 2.3 0.4 0.4 0.2 1.1 0.4 74 6 88 255 1 0.1 1.4 0.9 10/13/2005 19:30:00 1.8 0.3 2.3 1.1 1.3 0.4 2.3 0.4 0.7 0.3 1.5 0.4 68 10 79 255 0.8 0 0.9 0.7 10/13/2005 19:40:00 1.7 0.3 2.3 1.1 1.2 0.3 1.9 0.4 0.5 0.2 1.1 0.4 64 6 53 255 0.7 0 0.9 0.7 10/13/2005 19:50:00 2.1 0.3 2.6 1.5 1.7 0.4 2.6 0.7 1.1 0.4 2.3 0.4 63 7 69 255 0.7 0 0.7 0.7 10/13/2005 20:00:00 2.3 0.3 3 1.5 1.9 0.4 3 1.1 1.4 0.4 2.6 0.4 68 8 59 255 0.7 0 0.7 0.7 10/13/2005 20:10:00 2.1 0.3 3 1.5 1.6 0.4 2.6 0.7 0.9 0.4 2.6 0.4 80 9 81 255 0.5 0 0.7 0.2 10/13/2005 20:20:00 2.2 0.3 3.4 1.1 1.8 0.4 3 1.1 1 0.4 2.3 0.4 84 9 80 255 0.5 0 0.7 0.4 10/13/2005 20:30:00 2 0.3 2.6 1.1 1.5 0.4 2.6 0.4 0.9 0.4 1.9 0.4 77 9 70 255 0.7 0 0.9 0.7 10/13/2005 20:40:00 2.1 0.3 2.6 1.5 1.6 0.4 2.6 0.7 0.9 0.4 2.3 0.4 80 9 64 255 0.7 0 0.9 0.7 10/13/2005 20:50:00 2.5 0.3 3.4 1.9 2.2 0.3 3 1.5 1.6 0.3 2.6 0.7 69 7 64 255 0.7 0 0.9 0.7 10/13/2005 21:00:00 2.4 0.4 3.8 1.5 2.1 0.5 3.4 1.1 1.5 0.5 2.6 0.4 70 9 81 255 0.7 0 0.7 0.7 10/13/2005 21:10:00 2.1 0.3 3 1.5 1.8 0.4 3 0.7 1 0.4 2.3 0.4 68 9 73 255 0.3 0.1 0.7 -0.1 10/13/2005 21:20:00 2.3 0.5 3.4 1.5 1.9 0.6 3.8 0.4 1.1 0.6 2.3 0.4 62 12 74 255 -0.1 0 0.2 -0.3 10/13/2005 21:30:00 2.3 0.4 3.4 1.5 1.9 0.5 3 0.7 0.8 0.5 2.6 0.4 59 10 57 255 -0.4 0 -0.1 -0.5 10/13/2005 21:40:00 2 0.4 3 1.1 1.6 0.4 3 0.7 0.9 0.5 3 0.4 71 11 70 255 -0.6 0 -0.5 -0.7 10/13/2005 21:50:00 2 0.4 3.4 1.1 1.6 0.4 3.4 0.7 0.8 0.3 1.9 0.4 83 12 80 255 -0.8 0 -0.7 -0.7 10/13/2005 22:00:00 2 0.3 2.6 1.1 1.5 0.4 2.6 0.7 0.6 0.3 1.9 0.4 88 9 64 255 -0.9 0 -0.7 -1 10/13/2005 22:10:00 2 0.2 2.6 1.5 1.5 0.3 2.6 0.7 0.5 0.3 1.1 0.4 100 8 66 255 -1 0 -0.7 -1 10/13/2005 22:20:00 2.2 0.3 3 1.5 1.8 0.3 2.6 1.1 0.7 0.3 1.9 0.4 106 7 102 255 -0.9 0 -0.7 -1 10/13/2005 22:30:00 2.4 0.4 3.4 1.1 2.1 0.5 3.4 0.7 1.1 0.5 2.3 0.4 109 12 109 255 -1 0 -0.7 -1 10/13/2005 22:40:00 2.6 0.4 3.8 1.1 2.2 0.5 3.4 0.7 1.2 0.5 2.6 0.4 111 9 114 255 -1 0 -0.7 -1 10/13/2005 22:50:00 2.4 0.4 3.4 1.1 1.9 0.5 3 0.7 0.8 0.4 1.9 0.4 111 9 106 255 -1 0 -0.7 -1 10/13/2005 23:00:00 1.9 0.4 3 1.1 1.5 0.5 2.6 0.4 0.4 0.2 1.1 0.4 116 8 110 255 -1 0 -0.7 -1.2 10/13/2005 23:10:00 2.2 0.4 3 0.7 1.7 0.5 2.6 0.4 0.7 0.3 1.5 0.4 116 10 109 255 -1.3 0 -1.2 -1.4 10/13/2005 23:20:00 2.2 0.4 3 1.1 1.7 0.4 2.3 0.4 0.6 0.3 1.5 0.4 111 9 109 255 -1.6 0 -1.4 -1.7 10/13/2005 23:30:00 2 0.3 2.6 1.1 1.5 0.4 2.3 0.7 0.5 0.2 1.1 0.4 110 9 117 255 -1.7 0.1 -1.4 -1.9 10/13/2005 23:40:00 2.5 0.4 3.4 1.5 2.2 0.5 3 1.1 1.1 0.5 1.9 0.4 97 5 99 255 -2 0 -1.9 -2.1 10/13/2005 23:50:00 2.6 0.4 3.4 1.9 2.4 0.4 3.4 1.5 1 0.4 1.9 0.4 88 9 90 255 -2.2 0 -2.1 -2.4 10/14/2005 00:00:00 2.8 0.3 3.4 2.3 2.5 0.4 3.4 1.9 1 0.5 2.3 0.4 90 5 90 255 -2.4 0.1 -1.9 -2.6 10/14/2005 00:10:00 3.1 0.2 3.8 2.6 2.9 0.2 3.4 2.3 1.5 0.3 2.3 0.7 85 2 80 255 -2.2 0 -2.1 -2.4 10/14/2005 00:20:00 3.1 0.2 3.8 2.3 2.9 0.3 3.4 2.3 1.8 0.3 2.6 0.7 85 6 95 255 -2.1 0 -2.1 -2.1 10/14/2005 00:30:00 2.8 0.3 3.4 1.9 2.5 0.3 3.4 1.9 1.3 0.4 2.3 0.4 86 8 87 255 -2.1 0 -2.1 -2.1 10/14/2005 00:40:00 2.8 0.3 3.4 1.9 2.5 0.3 3.4 1.5 1.4 0.4 2.6 0.4 92 7 83 255 -2.1 0 -2.1 -2.1 10/14/2005 00:50:00 2.9 0.3 3.8 2.3 2.6 0.3 3 1.5 1.5 0.5 2.6 0.4 96 6 88 255 -2.3 0 -2.1 -2.6 10/14/2005 01:00:00 3.1 0.3 3.8 2.3 2.8 0.3 3.4 1.9 1.8 0.5 3 0.7 108 9 95 255 -2.5 0 -2.4 -2.6 10/14/2005 01:10:00 3.5 0.3 4.2 2.3 3.2 0.3 4.2 1.9 2 0.5 3 0.7 105 8 112 255 -2.6 0 -2.4 -2.6 10/14/2005 01:20:00 3 0.5 4.2 1.5 2.7 0.6 4.2 1.1 1.5 0.6 3.4 0.4 112 11 134 255 -2.6 0 -2.6 -2.8 10/14/2005 01:30:00 2.9 0.8 4.6 1.1 2.5 0.8 4.2 0.7 1.5 0.6 3.4 0.4 116 12 115 255 -2.6 0 -2.6 -2.6 10/14/2005 01:40:00 2.6 0.6 4.2 1.1 2.4 0.7 3.8 0.7 1.3 0.5 2.6 0.4 118 12 106 255 -2.6 0 -2.6 -2.8 10/14/2005 01:50:00 2.9 0.5 4.2 1.9 2.7 0.5 3.8 1.5 1.5 0.5 3 0.4 114 9 125 255 -2.6 0 -2.6 -2.8 10/14/2005 02:00:00 2.1 0.5 3.8 0.7 1.7 0.6 3.4 0.4 0.9 0.4 2.3 0.4 121 10 101 255 -2.6 0 -2.4 -2.6 10/14/2005 02:10:00 2.5 0.5 3.8 1.5 2.3 0.6 3.8 1.1 1.1 0.5 2.6 0.4 114 10 100 255 -2.6 0 -2.6 -2.6 10/14/2005 02:20:00 2.8 0.5 3.8 1.5 2.5 0.6 3.8 1.1 1.2 0.6 2.6 0.4 109 8 110 255 -2.6 0 -2.6 -2.6 10/14/2005 02:30:00 2.2 0.5 3 1.1 1.7 0.5 3 0.4 0.7 0.4 1.9 0.4 112 13 141 255 -2.7 0 -2.6 -2.8 10/14/2005 02:40:00 3.1 0.4 3.8 1.9 2.9 0.5 3.8 1.5 1.9 0.6 3.4 0.4 104 6 109 255 -2.8 0 -2.6 -2.8 10/14/2005 02:50:00 3.5 0.3 4.2 2.3 3.4 0.4 4.2 2.3 2.4 0.5 3.4 1.1 102 7 94 255 -2.9 0 -2.8 -3 10/14/2005 03:00:00 2.8 0.6 4.2 1.1 2.6 0.6 4.2 0.4 1.3 0.8 3 0.4 109 12 100 255 -2.8 0 -2.6 -3 10/14/2005 03:10:00 2.8 0.5 3.8 1.1 2.5 0.5 3.8 0.7 1.4 0.5 2.6 0.4 117 10 102 255 -2.9 0 -2.8 -3 10/14/2005 03:20:00 3 0.5 4.2 1.5 2.7 0.6 4.2 0.7 1.6 0.5 3 0.4 116 11 126 255 -3 0 -2.8 -3 10/14/2005 03:30:00 2.5 0.5 4.2 1.5 2.2 0.6 3.8 0.7 1 0.5 2.3 0.4 115 11 113 255 -2.9 0 -2.8 -3 10/14/2005 03:40:00 2.4 0.5 3.8 1.1 2.1 0.6 3.8 0.4 1 0.4 2.3 0.4 120 12 113 255 -2.8 0 -2.6 -3 10/14/2005 03:50:00 3.6 0.6 4.9 1.9 3.4 0.6 4.9 1.5 2 0.6 3.8 0.4 114 11 106 255 -2.8 0 -2.6 -2.8 10/14/2005 04:00:00 4.3 0.4 4.9 3.4 4.1 0.4 4.9 2.6 3 0.5 4.2 1.5 105 7 109 255 -2.6 0 -2.4 -2.8 10/14/2005 04:10:00 4.4 0.3 4.9 3 4.2 0.3 4.9 3 3.1 0.5 4.2 1.5 98 5 102 255 -2.3 0 -2.1 -2.6 10/14/2005 04:20:00 3.9 0.4 4.6 2.6 3.7 0.4 4.6 2.6 2.6 0.6 3.8 0.7 103 6 97 255 -2.4 0 -2.1 -2.6 10/14/2005 04:30:00 3.6 0.3 4.2 2.3 3.4 0.4 4.2 2.3 2.3 0.5 3.8 0.7 107 8 101 255 -2.3 0 -2.1 -2.6 10/14/2005 04:40:00 3.5 0.5 4.6 1.9 3.4 0.5 4.6 1.9 2.1 0.6 3.4 0.4 108 10 116 255 -2.6 0 -2.4 -2.6 10/14/2005 04:50:00 3.6 0.4 4.6 2.3 3.4 0.4 4.2 2.3 2.3 0.5 3.4 1.1 105 7 110 255 -2.5 0.1 -2.4 -2.6 10/14/2005 05:00:00 3.6 0.5 4.6 2.3 3.4 0.5 4.6 1.9 2.2 0.6 3.8 0.7 107 7 99 255 -2.6 0 -2.4 -2.8 10/14/2005 05:10:00 4.2 0.4 4.9 3 4.1 0.4 4.9 2.6 3 0.5 4.2 1.1 101 6 86 255 -2.7 0 -2.6 -2.8 10/14/2005 05:20:00 4 0.4 4.9 2.6 3.8 0.4 4.9 2.3 2.7 0.5 4.2 1.5 105 7 104 255 -2.4 0.2 -2.1 -2.6 10/14/2005 05:30:00 3.9 0.5 4.9 2.6 3.7 0.4 4.6 2.3 2.4 0.6 3.8 0.4 109 9 125 255 -2.4 0.1 -2.1 -2.6 10/14/2005 05:40:00 3.9 0.6 5.3 2.3 3.8 0.5 4.9 1.9 2.7 0.6 4.2 0.7 109 10 109 255 -2.3 0.1 -2.1 -2.6 10/14/2005 05:50:00 3.8 0.5 5.3 2.3 3.6 0.5 4.9 1.9 2.4 0.6 4.2 0.7 110 11 98 255 -1.8 0 -1.4 -2.1 10/14/2005 06:00:00 3.5 0.5 4.9 1.9 3.3 0.6 4.6 1.9 2.2 0.6 3.4 0.7 112 12 112 255 -1.6 0 -1.4 -1.9 10/14/2005 06:10:00 3.8 0.6 5.3 2.3 3.5 0.6 4.9 1.5 2.4 0.7 4.2 0.7 112 12 103 255 -1.6 0 -1.4 -1.7 10/14/2005 06:20:00 4 0.6 5.3 1.1 3.7 0.7 5.3 1.1 2.6 0.9 4.6 0.7 110 12 103 255 -1.4 0.1 -1.2 -1.7 10/14/2005 06:30:00 4.4 0.7 6.5 2.3 4.3 0.7 5.7 2.3 3 0.9 5.3 0.7 109 11 103 255 -1 0 -0.7 -1.2 10/14/2005 06:40:00 4.1 0.7 6.1 1.9 3.9 0.7 5.7 1.9 3 0.7 4.9 1.1 106 11 113 255 -0.7 0 -0.5 -0.7 10/14/2005 06:50:00 2.6 0.6 4.2 1.1 2.5 0.7 3.8 0.7 1.5 0.6 3.4 0.4 90 14 98 255 -0.8 0.2 -0.5 -1.2 10/14/2005 07:00:00 2.6 0.4 3.4 1.9 2.4 0.4 3.4 1.5 1.6 0.3 2.3 0.7 96 7 95 255 -1.3 0.1 -1.2 -1.7 10/14/2005 07:10:00 3.2 0.4 4.2 2.3 3 0.4 3.8 1.9 2 0.4 3 0.7 100 5 104 255 -1.7 0 -1.4 -1.9 10/14/2005 07:20:00 3.2 0.4 4.2 1.9 3 0.4 4.2 1.9 1.9 0.5 3 0.4 102 8 101 255 -1.5 0 -1.2 -1.7 10/14/2005 07:30:00 3.3 0.4 4.2 1.9 3.1 0.5 4.2 1.5 2.2 0.5 3.4 0.7 96 6 86 255 -1.2 0 -1 -1.2 10/14/2005 07:40:00 3.4 0.5 4.9 2.3 3.3 0.5 4.6 1.9 2.4 0.6 4.2 0.7 103 9 102 255 -0.9 0 -0.5 -1.2 10/14/2005 07:50:00 3 0.6 4.6 1.1 2.9 0.6 4.2 0.7 2.1 0.7 3.8 0.4 110 13 92 255 -0.5 0.1 -0.3 -0.7 10/14/2005 08:00:00 3.4 0.5 4.6 1.5 3.1 0.5 4.6 1.1 2.2 0.6 3.8 0.4 107 10 97 255 -0.2 0 -0.1 -0.5 10/14/2005 08:10:00 3.4 0.6 4.6 1.9 3.1 0.6 4.6 1.5 2.3 0.7 4.2 0.4 107 11 112 255 -0.1 0 0.2 -0.1 10/14/2005 08:20:00 3.4 0.8 5.3 1.1 3.2 0.8 5.7 1.5 2.4 0.8 4.2 0.7 109 12 105 255 0.3 0 0.7 0.2 10/14/2005 08:30:00 3.3 0.6 4.9 1.5 3.1 0.6 4.9 1.5 2.4 0.7 4.2 0.7 108 14 115 255 0.6 0 0.7 0.4 10/14/2005 08:40:00 3.3 0.6 4.9 1.9 3.1 0.6 4.6 1.5 2.4 0.7 3.8 0.7 100 11 100 255 0.7 0 0.7 0.7 10/14/2005 08:50:00 3.5 0.6 4.9 1.9 3.3 0.7 4.9 1.5 2.7 0.8 4.9 0.7 103 12 115 255 0.7 0 0.9 0.7 10/14/2005 09:00:00 2.6 0.7 4.2 1.1 2.3 0.7 3.8 0.7 1.6 0.7 3.8 0.4 93 20 106 255 0.8 0 0.9 0.9 10/14/2005 09:10:00 3.1 0.6 4.9 1.5 2.9 0.6 4.6 0.7 2.2 0.7 4.2 0.7 108 11 118 255 0.9 0 1.1 0.9 10/14/2005 09:20:00 3.3 0.6 4.6 1.1 3.1 0.7 4.6 1.1 2.4 0.8 4.2 0.4 104 13 119 255 1.2 0 1.4 0.9 10/14/2005 09:30:00 3 0.5 4.9 1.9 2.8 0.5 4.2 1.1 2.2 0.6 3.8 0.7 100 13 99 255 1.2 0 1.4 1.4 10/14/2005 09:40:00 3.3 0.6 5.3 1.9 3.1 0.6 4.9 1.5 2.6 0.7 4.6 1.1 105 14 106 255 1.2 0 1.4 1.4 10/14/2005 09:50:00 2.9 0.7 4.6 0.4 2.6 0.7 4.2 0.4 2.1 0.9 3.8 0.4 100 15 99 255 1.3 0 1.4 1.4 10/14/2005 10:00:00 3.1 0.6 4.6 1.5 2.7 0.7 4.6 0.7 2.3 0.8 4.2 0.4 98 12 89 255 1.4 0 1.6 1.4 10/14/2005 10:10:00 2.8 0.8 4.6 0.4 2.5 0.8 4.2 0.4 2.1 0.8 3.8 0.4 96 14 104 255 1.5 0 1.6 1.4 10/14/2005 10:20:00 3.4 0.7 4.9 1.5 3.2 0.7 4.6 1.5 2.6 0.8 4.6 0.4 101 12 106 255 1.7 0 1.8 1.6 10/14/2005 10:30:00 3.6 0.8 5.3 1.5 3.4 0.8 4.9 1.1 2.6 1 4.6 0.4 101 12 83 255 1.8 0 1.8 1.8 10/14/2005 10:40:00 3.5 0.7 4.9 1.5 3.2 0.8 5.3 0.4 2.9 0.8 4.9 0.7 104 13 87 255 2 0 2.3 1.8 10/14/2005 10:50:00 3.8 0.7 5.3 1.9 3.6 0.7 5.3 1.5 3 0.9 4.9 0.7 100 11 105 255 2.3 0 2.3 2.1 10/14/2005 11:00:00 3.6 0.7 4.9 1.9 3.4 0.8 4.9 1.5 2.8 0.9 4.9 0.4 101 13 97 255 2.3 0 2.6 2.3 10/14/2005 11:10:00 3.6 0.8 5.3 1.1 3.5 0.8 5.3 1.1 2.9 0.8 4.6 1.1 100 13 96 255 2.4 0.1 2.6 2.3 10/14/2005 11:20:00 3.4 0.7 4.9 1.9 3.2 0.8 4.9 1.1 2.5 0.9 4.6 0.4 92 15 90 255 2.7 0 2.8 2.6 10/14/2005 11:30:00 3.5 0.7 5.3 1.5 3.2 0.7 4.6 1.1 2.7 0.7 4.2 0.7 99 14 110 255 2.9 0 3 2.8 10/14/2005 11:40:00 3.4 0.6 4.9 1.9 3.1 0.7 4.6 1.1 2.7 0.8 4.2 0.7 99 11 106 255 3.1 0 3.3 2.8 10/14/2005 11:50:00 3.2 0.8 4.9 1.1 3 0.8 4.6 1.1 2.6 1 4.2 0.4 97 13 102 255 3.2 0 3.5 3.3 10/14/2005 12:00:00 3.1 0.8 4.9 0.7 2.9 0.9 4.6 0.4 2.4 0.8 4.6 0.4 95 12 97 255 3.5 0 3.5 3.5 10/14/2005 12:10:00 2.8 0.8 4.9 0.4 2.4 1 4.6 0.4 2 0.9 4.2 0.4 94 15 113 255 3.5 0 3.8 3.5 10/14/2005 12:20:00 2.7 0.5 3.8 1.5 2.4 0.6 3.8 0.7 1.9 0.8 3.4 0.4 99 11 78 255 3.6 0 3.8 3.5 10/14/2005 12:30:00 2.9 0.8 4.9 1.5 2.6 0.8 4.6 0.7 2.3 0.8 4.2 0.7 98 14 124 255 3.7 0 3.8 3.5 10/14/2005 12:40:00 3 0.7 4.6 0.7 2.7 0.8 4.6 0.4 2.3 0.8 4.6 0.4 99 12 81 255 3.7 0 3.8 3.5 10/14/2005 12:50:00 2.3 0.6 4.2 0.7 1.9 0.7 3.8 0.4 1.6 0.7 3.4 0.4 90 11 96 255 3.9 0 4 3.8 10/14/2005 13:00:00 3.2 0.8 4.9 1.5 2.9 0.8 4.6 0.7 2.3 0.8 4.2 0.4 99 12 102 255 4 0 4 4 10/14/2005 13:10:00 3.2 0.5 4.6 1.9 3 0.5 4.2 1.9 2.6 0.6 4.6 1.1 96 10 100 255 4 0 4 4 10/14/2005 13:20:00 2.6 0.6 4.2 1.1 2.3 0.7 3.8 0.7 1.9 0.8 3.8 0.4 99 13 97 255 4 0 4.3 4 10/14/2005 13:30:00 2.6 0.6 3.8 1.1 2.2 0.7 3.4 0.4 1.8 0.7 3.4 0.4 90 12 87 255 4 0 4.3 4 10/14/2005 13:40:00 2.9 0.5 3.8 1.5 2.6 0.5 3.8 1.1 2.2 0.6 3.8 0.7 95 9 90 255 4.3 0 4.5 4.3 10/14/2005 13:50:00 1.9 0.6 3.4 0.7 1.4 0.7 3 0.4 1 0.6 2.6 0.4 100 18 87 255 4.4 0 4.5 4.3 10/14/2005 14:00:00 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 76 13 94 255 4.6 0 4.8 4.5 10/14/2005 14:10:00 2 0.6 3.4 0.4 1.6 0.6 3 0.4 1.2 0.7 2.6 0.4 93 11 93 255 4.7 0 4.8 4.5 10/14/2005 14:20:00 2.4 0.5 3.4 1.1 2 0.6 3.4 0.4 1.8 0.6 3 0.4 101 10 105 255 4.9 0 5 4.8 10/14/2005 14:30:00 2.7 0.5 4.2 1.5 2.3 0.6 3.8 0.7 1.9 0.5 3 0.4 105 11 121 255 5 0 5 5 10/14/2005 14:40:00 3.2 0.6 4.6 1.5 2.9 0.7 4.2 1.1 2.4 0.7 4.2 0.7 106 11 115 255 5.1 0 5 5 10/14/2005 14:50:00 2.9 0.6 4.2 1.5 2.6 0.6 4.2 1.1 2.2 0.7 3.8 0.4 104 13 100 255 5.1 0 5 5 10/14/2005 15:00:00 2.3 1 4.6 0.4 1.8 1.1 4.2 0.4 1.7 1 3.8 0.4 93 16 103 255 5.1 0 5.2 5 10/14/2005 15:10:00 0.7 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.5 0.4 102 32 104 255 5.1 0 5.2 5 10/14/2005 15:20:00 1.7 0.7 3 0.4 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 84 33 97 255 5.1 0 5.2 5 10/14/2005 15:30:00 1.1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.5 0.4 72 27 70 255 5.1 0 5 5 10/14/2005 15:40:00 0.9 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 49 53 108 255 4.9 0 5 4.8 10/14/2005 15:50:00 1.3 0.7 3.4 0.4 0.8 0.7 3 0.4 0.5 0.4 2.3 0.4 55 61 97 255 4.6 0 4.8 4.5 10/14/2005 16:00:00 3 0.7 4.6 1.5 2.8 0.8 4.6 0.7 2.3 0.8 4.2 0.4 109 17 101 255 4.6 0 4.8 4.5 10/14/2005 16:10:00 3.3 0.8 5.3 1.9 2.9 0.9 5.3 1.1 2.4 0.8 4.2 0.7 118 15 112 255 4.8 0 5 4.8 10/14/2005 16:20:00 2.5 0.6 4.2 1.5 2.1 0.6 3.8 0.7 1.6 0.6 3 0.4 98 13 103 255 4.8 0 5 4.8 10/14/2005 16:30:00 2.9 0.7 4.6 1.5 2.5 0.8 4.2 0.7 1.9 0.8 3.8 0.4 96 16 98 255 4.8 0 5 4.8 10/14/2005 16:40:00 3 0.6 4.9 1.5 2.7 0.7 4.6 0.7 2 0.8 3.8 0.4 106 14 93 255 4.8 0 5 4.8 10/14/2005 16:50:00 3.2 0.7 5.3 1.9 2.8 0.8 4.6 0.7 2.2 0.8 4.6 0.4 111 15 106 255 4.9 0 5 4.8 10/14/2005 17:00:00 2.9 0.8 4.9 0.7 2.6 0.9 4.6 0.4 2 0.9 4.6 0.4 112 17 106 255 5 0 5 5 10/14/2005 17:10:00 2.7 0.6 4.6 1.1 2.3 0.7 4.2 0.4 1.6 0.6 3.4 0.4 106 15 106 255 4.9 0 5 4.8 10/14/2005 17:20:00 2.8 0.6 4.6 1.1 2.4 0.7 4.2 0.7 1.9 0.7 3.4 0.4 102 13 104 255 4.9 0 5 4.8 10/14/2005 17:30:00 2.3 0.8 4.6 0.4 2 0.9 4.2 0.4 1.4 0.8 3.4 0.4 92 14 92 255 4.9 0 5 4.8 10/14/2005 17:40:00 0.9 0.6 3 0.4 0.6 0.5 2.3 0.4 0.4 0.1 1.1 0.4 73 51 83 255 4.6 0 4.8 4.5 10/14/2005 17:50:00 1.7 0.6 3.4 0.7 1.1 0.7 3 0.4 0.9 0.5 2.6 0.4 358 56 105 255 4.4 0 4.5 4.3 10/14/2005 18:00:00 2.2 0.8 4.2 0.4 1.8 0.9 3.8 0.4 1.3 1 4.2 0.4 69 17 78 255 4.5 0 4.5 4.3 10/14/2005 18:10:00 1.6 0.5 3 0.7 1.1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 62 15 48 255 4.3 0 4.5 4.3 10/14/2005 18:20:00 1.5 0.6 3.8 0.4 1 0.6 3 0.4 0.8 0.5 3 0.4 50 20 65 255 4.3 0 4.5 4 10/14/2005 18:30:00 1.4 0.8 3.4 0.4 1 0.7 3 0.4 0.6 0.5 2.6 0.4 81 17 93 255 3.9 0 4.3 3.8 10/14/2005 18:40:00 2 0.5 3 0.7 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 73 13 86 255 3.6 0 3.8 3.5 10/14/2005 18:50:00 2.6 0.6 4.2 1.1 2.2 0.7 3.8 0.4 1.6 0.6 3 0.4 80 13 83 255 3.9 0 4 3.8 10/14/2005 19:00:00 3.3 0.6 4.9 1.1 3.1 0.7 4.6 0.7 2.3 0.8 4.6 0.4 87 13 84 255 4.1 0.1 4.5 4 10/14/2005 19:10:00 2.8 0.6 4.2 1.5 2.4 0.8 3.8 0.4 1.8 0.9 3.4 0.4 88 9 83 255 4.4 0 4.5 4.3 10/14/2005 19:20:00 2.5 0.5 3.8 1.5 2.1 0.6 3.4 0.7 1.6 0.6 3 0.4 94 16 79 255 4.3 0 4.5 4.3 10/14/2005 19:30:00 2.6 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1.6 0.6 2.6 0.4 106 11 98 255 4 0 4.3 4 10/14/2005 19:40:00 2.3 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.3 0.8 3 0.4 84 19 86 255 4.1 0 4.3 4.3 10/14/2005 19:50:00 1.9 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 15 29 36 255 4 0 4.3 3.8 10/14/2005 20:00:00 2 0.4 3 1.1 1.6 0.4 3 0.4 0.9 0.4 1.9 0.4 36 30 68 255 3.5 0 3.8 3.5 10/14/2005 20:10:00 2.5 0.4 3.4 1.9 2.1 0.4 3.4 0.7 1.3 0.6 2.6 0.4 70 10 80 255 3.5 0 3.5 3.5 10/14/2005 20:20:00 1.9 0.6 3.4 0.7 1.4 0.7 3.4 0.4 0.7 0.5 2.6 0.4 67 13 85 255 3.3 0.1 3.5 3.3 10/14/2005 20:30:00 2 0.5 3 0.4 1.5 0.6 2.6 0.4 0.8 0.5 2.6 0.4 80 15 80 255 3 0 3.3 2.8 10/14/2005 20:40:00 2.9 0.6 4.6 1.1 2.6 0.7 4.6 0.7 1.9 0.6 3.8 0.4 87 12 93 255 3.1 0.2 3.5 2.8 10/14/2005 20:50:00 3.4 0.6 4.9 1.9 3.1 0.7 4.6 1.5 2.3 0.8 3.8 0.4 92 12 83 255 3.9 0.2 4.3 3.5 10/14/2005 21:00:00 3 0.7 4.9 1.5 2.7 0.8 4.6 1.1 2.2 0.9 4.2 0.4 100 14 97 255 4.4 0 4.5 4.3 10/14/2005 21:10:00 3.1 0.6 4.9 1.9 2.8 0.6 4.6 1.5 2 0.7 4.2 0.7 95 15 100 255 4.5 0 4.5 4.5 10/14/2005 21:20:00 1.8 0.5 3.4 0.7 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 80 15 104 255 4.3 0.1 4.5 4 10/14/2005 21:30:00 1.9 0.4 3 1.1 1.3 0.5 3 0.4 0.6 0.4 2.3 0.4 79 9 79 255 3.8 0.1 4 3.5 10/14/2005 21:40:00 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 68 13 84 255 3.5 0 3.5 3.3 10/14/2005 21:50:00 1.3 0.2 1.9 0.7 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 38 9 51 255 3.2 0 3.5 3 10/14/2005 22:00:00 1.2 0.2 1.9 0.7 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 20 6 34 255 2.9 0 3.3 2.8 10/14/2005 22:10:00 2.1 0.4 3 0.7 1.5 0.5 2.6 0.4 0.9 0.4 1.9 0.4 70 15 73 255 2.7 0 2.8 2.6 10/14/2005 22:20:00 1.3 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 84 0 84 255 2.4 0 2.6 2.3 10/14/2005 22:30:00 2.2 0.4 3 1.1 1.6 0.4 2.6 0.4 0.9 0.4 1.9 0.4 87 4 91 255 2.3 0 2.6 2.3 10/14/2005 22:40:00 1.9 0.4 3 1.1 1.3 0.5 2.6 0.4 0.6 0.3 1.5 0.4 95 9 96 255 2.1 0 2.3 1.8 10/14/2005 22:50:00 2.1 0.4 3.4 1.1 1.6 0.5 2.6 0.4 0.8 0.4 1.9 0.4 94 4 106 255 2 0 2.1 1.8 10/14/2005 23:00:00 1.9 0.3 3.4 1.1 1.2 0.4 2.6 0.4 0.5 0.2 2.3 0.4 87 7 84 255 1.8 0 2.1 1.8 10/14/2005 23:10:00 2.7 0.4 3.8 1.9 2.3 0.5 3.4 0.7 1.7 0.5 2.6 0.4 92 8 91 255 1.9 0.1 2.3 1.8 10/14/2005 23:20:00 2.7 0.5 4.2 1.9 2.2 0.6 3.4 0.7 1.8 0.5 3 0.7 96 11 113 255 2.3 0.2 2.8 2.1 10/14/2005 23:30:00 2.6 0.6 4.2 1.1 2.1 0.7 3.8 0.4 1.3 0.7 2.6 0.4 98 13 102 255 2.9 0 2.8 2.6 10/14/2005 23:40:00 1.1 0.7 3 0.4 0.7 0.5 2.6 0.4 0.4 0.2 1.9 0.4 57 35 71 255 2.4 0.2 2.8 2.1 10/14/2005 23:50:00 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 26 27 40 255 1.6 0.2 2.1 1.1 10/15/2005 00:00:00 1.4 0.7 2.6 0.4 0.8 0.5 2.3 0.4 0.5 0.2 1.5 0.4 64 22 88 255 0.8 0.1 1.4 0.7 10/15/2005 00:10:00 2.4 0.3 3.4 1.9 1.9 0.4 3 1.1 1.2 0.4 2.3 0.4 86 7 93 255 0.4 0.2 0.7 -0.1 10/15/2005 00:20:00 2.5 0.4 3.4 1.5 2 0.4 3 0.7 1.2 0.3 2.3 0.4 87 6 79 255 -0.2 0.1 0.2 -0.5 10/15/2005 00:30:00 2.5 0.3 3.4 1.9 2.1 0.4 3 1.1 1 0.3 1.9 0.4 87 6 90 255 -0.6 0 -0.3 -0.7 10/15/2005 00:40:00 3 0.4 4.2 1.9 2.6 0.5 3.8 1.9 1.5 0.5 2.6 0.4 102 8 102 255 -0.7 0 -0.5 -0.7 10/15/2005 00:50:00 3.1 0.4 4.2 1.9 2.7 0.4 3.8 1.5 1.4 0.5 3 0.4 109 9 110 255 -0.6 0 -0.5 -0.7 10/15/2005 01:00:00 2.5 0.4 3.4 1.5 2.1 0.4 3 0.4 0.9 0.5 2.3 0.4 102 9 117 255 -0.7 0.1 -0.5 -1 10/15/2005 01:10:00 2.2 0.4 3 1.1 1.7 0.5 3 0.7 0.5 0.3 1.5 0.4 94 5 101 255 -1.1 0 -1 -1.2 10/15/2005 01:20:00 2.4 0.3 3 1.5 2 0.4 2.6 1.1 0.8 0.4 1.9 0.4 104 8 95 255 -1.2 0 -1 -1.4 10/15/2005 01:30:00 2.3 0.3 3 1.5 1.9 0.4 2.6 1.1 0.6 0.4 1.9 0.4 98 6 102 255 -1.4 0 -1.2 -1.4 10/15/2005 01:40:00 2.5 0.3 3.4 1.9 2.1 0.4 3 1.1 0.9 0.5 2.6 0.4 95 7 99 255 -1.3 0.1 -1.2 -1.4 10/15/2005 01:50:00 1.4 0.7 2.6 0.4 0.9 0.6 2.3 0.4 0.4 0 0.7 0.4 98 4 96 255 -1.6 0 -1.4 -1.7 10/15/2005 02:00:00 0.9 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 54 28 77 255 -1.8 0 -1.7 -1.9 10/15/2005 02:10:00 1.3 0.4 2.6 0.4 0.7 0.4 2.3 0.4 0.4 0 0.4 0.4 51 20 81 255 -1.6 0 -1.4 -1.9 10/15/2005 02:20:00 2 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.6 0.3 1.5 0.4 81 7 82 255 -1.6 0 -1.4 -1.7 10/15/2005 02:30:00 3.3 0.8 5.3 1.5 2.9 0.9 5.3 0.7 1.9 1 4.6 0.4 96 13 83 255 -1.4 0.2 -0.7 -1.4 10/15/2005 02:40:00 3.9 0.7 5.7 1.9 3.7 0.7 5.3 1.9 2.8 0.9 4.6 0.7 101 11 110 255 0.1 0.5 0.9 -0.7 10/15/2005 02:50:00 4.4 0.7 6.5 2.3 4.2 0.8 6.1 2.3 3.2 0.9 5.3 1.1 103 12 98 255 1.2 0.2 1.6 0.9 10/15/2005 03:00:00 4 0.8 5.7 1.9 3.8 0.9 5.7 1.5 3 0.8 4.9 0.7 100 12 103 255 1.5 0 1.6 1.4 10/15/2005 03:10:00 3.7 0.7 6.1 2.3 3.5 0.7 5.7 1.9 2.7 0.8 4.9 0.4 95 12 91 255 1.6 0 1.6 1.6 10/15/2005 03:20:00 3.2 0.7 5.7 1.9 2.9 0.8 5.3 1.5 2.1 0.8 4.6 0.4 87 11 94 255 1.5 0 1.6 1.4 10/15/2005 03:30:00 2.4 0.5 3.8 1.1 2 0.6 3.8 0.7 1.2 0.6 2.3 0.4 78 10 74 255 1.3 0 1.6 0.9 10/15/2005 03:40:00 2.1 0.3 3 1.5 1.7 0.4 2.6 0.7 1 0.4 2.3 0.4 74 6 93 255 0.5 0.3 1.1 -0.1 10/15/2005 03:50:00 2.8 0.5 4.2 1.9 2.4 0.6 4.2 1.1 1.5 0.6 3 0.4 82 8 93 255 -0.3 0.1 -0.1 -0.5 10/15/2005 04:00:00 2.9 0.5 4.2 1.9 2.6 0.5 3.8 1.5 1.6 0.5 3 0.4 92 8 90 255 -0.6 0 -0.5 -0.7 10/15/2005 04:10:00 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.5 1.8 0.5 3.4 0.7 83 9 94 255 -0.5 0.1 -0.3 -0.7 10/15/2005 04:20:00 3.5 0.5 4.9 2.3 3.2 0.5 4.6 1.9 2.2 0.6 4.2 1.1 88 9 87 255 -0.2 0 -0.1 -0.5 10/15/2005 04:30:00 3.8 0.5 4.9 2.3 3.6 0.6 5.3 2.3 2.7 0.7 4.6 0.7 91 9 81 255 0.1 0.1 0.7 -0.1 10/15/2005 04:40:00 3.2 0.6 5.3 1.9 2.9 0.6 5.3 1.5 2 0.7 4.2 0.4 95 11 85 255 0.7 0 0.9 0.7 10/15/2005 04:50:00 3.1 0.5 4.6 1.9 2.9 0.5 3.8 1.5 1.9 0.7 3.4 0.4 104 12 108 255 0.7 0 0.9 0.7 10/15/2005 05:00:00 2.8 0.5 4.6 1.5 2.4 0.6 4.2 0.7 1.4 0.7 3.4 0.4 102 11 100 255 0.5 0 0.9 0.4 10/15/2005 05:10:00 3.1 0.9 5.3 1.1 2.9 1 5.3 0.7 2.1 1 4.2 0.4 96 17 79 255 0.5 0.1 0.7 0.2 10/15/2005 05:20:00 3.3 0.6 4.9 2.3 3 0.6 4.6 1.9 2.2 0.7 4.2 0.7 92 12 89 255 0.9 0 1.1 0.7 10/15/2005 05:30:00 3.7 0.7 5.7 2.3 3.5 0.7 5.7 1.9 2.6 0.7 4.6 1.1 96 10 107 255 1 0 1.4 0.9 10/15/2005 05:40:00 3.9 0.8 6.1 1.9 3.7 0.8 5.7 1.5 2.8 0.8 4.6 0.7 95 11 97 255 1.3 0 1.6 1.1 10/15/2005 05:50:00 2.7 0.7 4.6 1.5 2.5 0.7 4.6 0.4 1.6 0.7 3.4 0.4 94 15 45 255 1.4 0 1.6 1.4 10/15/2005 06:00:00 3.3 0.8 4.9 1.5 3 0.8 4.9 1.1 2.4 0.8 4.6 0.7 95 16 88 255 1.6 0 1.8 1.4 10/15/2005 06:10:00 3.4 0.7 4.9 1.5 3.1 0.7 5.3 1.5 2.5 0.7 4.6 0.7 97 14 91 255 1.8 0 1.8 1.6 10/15/2005 06:20:00 3.6 0.8 5.7 1.5 3.4 0.9 5.3 0.7 2.7 1.1 4.9 0.4 92 16 97 255 1.8 0 1.8 1.8 10/15/2005 06:30:00 3.3 0.8 5.3 1.5 3.1 0.9 4.9 0.7 2.5 0.9 4.9 0.4 85 16 97 255 1.8 0 1.8 1.8 10/15/2005 06:40:00 3 0.8 4.9 1.1 2.7 0.8 4.9 0.4 2.2 0.9 4.6 0.4 77 20 68 255 1.8 0 1.8 1.8 10/15/2005 06:50:00 3.4 0.6 4.9 1.9 3.2 0.7 4.6 1.5 2.6 0.7 4.2 0.7 74 15 58 255 1.8 0 1.8 1.6 10/15/2005 07:00:00 1.8 0.7 4.2 0.7 1.3 0.9 4.2 0.4 0.7 0.5 3 0.4 65 19 79 255 1.5 0.1 1.8 1.4 10/15/2005 07:10:00 2.4 0.7 4.9 0.7 2.1 0.8 4.6 0.4 1.1 0.8 3.4 0.4 88 15 83 255 0.9 0.1 1.4 0.7 10/15/2005 07:20:00 2.8 0.7 5.3 0.7 2.5 0.8 4.9 0.4 1.6 0.7 3.8 0.4 89 20 96 255 0.9 0 1.4 0.7 10/15/2005 07:30:00 3.9 1.4 8 1.1 3.7 1.5 8 1.1 2.7 1.4 7.6 0.4 79 19 127 255 1.4 0.2 1.8 1.1 10/15/2005 07:40:00 4.4 1.2 7.2 1.9 4.2 1.2 7.2 0.7 3.4 0.8 6.8 1.5 85 18 108 255 2 0 2.3 1.8 10/15/2005 07:50:00 3.9 1 7.2 1.5 3.8 1 7.2 1.1 3 0.9 5.7 0.7 77 19 85 255 2.3 0 2.3 2.3 10/15/2005 08:00:00 3.6 1 6.1 1.9 3.5 1 6.5 1.5 2.7 1.2 6.1 0.4 73 17 76 255 2.4 0 2.6 2.3 10/15/2005 08:10:00 2.9 0.8 4.9 1.5 2.6 0.8 4.9 0.7 2.1 0.9 4.9 0.4 50 20 76 255 2 0.3 2.6 1.4 10/15/2005 08:20:00 2.6 0.5 5.3 1.1 2.4 0.6 4.9 0.4 1.4 0.5 3 0.4 44 15 55 255 0.9 0.2 1.4 0.7 10/15/2005 08:30:00 2.1 0.8 4.6 0.4 1.8 0.8 4.2 0.4 0.7 0.6 3.8 0.4 60 21 53 255 0.5 0 0.7 0.4 10/15/2005 08:40:00 3.5 0.8 5.7 1.5 3.3 0.9 5.3 1.1 2.3 0.9 4.9 0.4 77 16 74 255 1 0.3 1.6 0.4 10/15/2005 08:50:00 4.3 1.3 7.6 1.5 4.2 1.3 8 1.1 3.4 1.3 7.6 0.7 80 17 81 255 2.4 0.4 3 1.6 10/15/2005 09:00:00 4.2 1.1 7.2 1.9 4 1.2 7.2 1.5 3.4 1.2 6.5 0.7 72 19 83 255 3.1 0 3.3 2.8 10/15/2005 09:10:00 3 0.5 4.6 1.5 2.8 0.5 4.6 1.5 2.1 0.5 3.8 0.4 30 19 356 255 2.2 0.5 3.3 1.6 10/15/2005 09:20:00 2.1 0.4 3 1.5 1.7 0.4 3 0.4 1.1 0.4 1.9 0.4 12 10 17 255 1.3 0.1 1.6 1.1 10/15/2005 09:30:00 1.3 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 21 13 7 255 1.2 0 1.4 1.1 10/15/2005 09:40:00 1.9 0.5 4.2 0.7 1.4 0.6 3.4 0.4 0.7 0.4 2.3 0.4 20 16 49 255 1.4 0 1.6 1.4 10/15/2005 09:50:00 1.6 0.3 2.6 0.7 1 0.4 2.3 0.4 0.4 0.2 1.1 0.4 12 11 43 255 1.7 0 1.8 1.6 10/15/2005 10:00:00 1.6 0.3 2.3 0.7 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 6 12 349 255 1.8 0 1.8 1.8 10/15/2005 10:10:00 1.4 0.4 2.3 0.7 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 358 3 0 255 1.8 0 2.1 1.8 10/15/2005 10:20:00 1.3 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 13 19 32 255 2 0 2.3 1.8 10/15/2005 10:30:00 1.5 0.4 3.4 0.7 0.9 0.5 3 0.4 0.5 0.3 2.3 0.4 14 29 60 255 2.2 0 2.3 2.1 10/15/2005 10:40:00 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 13 10 0 255 2.4 0 2.6 2.3 10/15/2005 10:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 3 13 15 255 2.5 0 2.8 2.3 10/15/2005 11:00:00 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 349 0 349 255 2.9 0.1 3.3 2.6 10/15/2005 11:10:00 1.4 0.3 2.3 0.7 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 11 6 255 3.2 0 3.3 3 10/15/2005 11:20:00 1.3 0.3 2.3 0.7 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 359 10 9 255 3.2 0 3.3 3 10/15/2005 11:30:00 1.1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 359 6 355 255 3.3 0 3.5 3.3 10/15/2005 11:40:00 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 354 8 350 255 3.5 0.1 3.8 3.3 10/15/2005 11:50:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 350 5 350 255 3.8 0 4 3.5 10/15/2005 12:00:00 1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 354 6 356 255 4.1 0 4.5 4 10/15/2005 12:10:00 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 349 10 350 255 4.5 0 4.8 4.5 10/15/2005 12:20:00 1.2 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 347 7 349 255 4.6 0 4.8 4.5 10/15/2005 12:30:00 1.1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 342 13 345 255 4.8 0 5 4.8 10/15/2005 12:40:00 0.9 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0 19 28 255 4.9 0 5 4.8 10/15/2005 12:50:00 1 0.4 2.3 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 340 9 345 255 5.2 0.1 5.5 5 10/15/2005 13:00:00 0.9 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 348 13 339 255 5.5 0 5.7 5.5 10/15/2005 13:10:00 1.1 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 359 14 351 255 5.6 0 5.7 5.5 10/15/2005 13:20:00 1.3 0.4 2.3 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 330 19 356 255 5.9 0 6.2 5.7 10/15/2005 13:30:00 1.6 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 326 19 306 255 6.2 0 6.2 6 10/15/2005 13:40:00 1.4 0.3 2.3 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 347 10 12 255 6.1 0 6.2 6 10/15/2005 13:50:00 1.4 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 336 15 320 255 6.2 0 6.2 6 10/15/2005 14:00:00 1.3 0.4 2.3 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.9 0.4 313 20 320 255 5.8 0.1 6.2 5.7 10/15/2005 14:10:00 1.3 0.4 2.3 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 308 7 328 255 5.7 0 5.7 5.7 10/15/2005 14:20:00 1.2 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 315 11 307 255 5.8 0 6 5.7 10/15/2005 14:30:00 1.6 0.5 2.6 0.4 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 313 17 303 255 6.2 0 6.2 6 10/15/2005 14:40:00 1.7 0.4 2.6 0.7 1.1 0.4 2.3 0.4 1 0.5 2.3 0.4 307 12 313 255 5.9 0.1 6.2 5.7 10/15/2005 14:50:00 1.5 0.6 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 300 15 273 255 5.6 0 5.7 5.5 10/15/2005 15:00:00 2 0.4 3 0.7 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 300 13 313 255 5.2 0.1 5.5 5 10/15/2005 15:10:00 1.6 0.5 2.3 0.4 0.9 0.4 1.9 0.4 0.8 0.5 2.3 0.4 304 11 308 255 5.1 0 5.2 5 10/15/2005 15:20:00 1.7 0.4 2.6 0.7 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 300 12 294 255 5 0 5 4.8 10/15/2005 15:30:00 1.7 0.4 2.6 0.4 1.1 0.4 2.3 0.4 0.8 0.5 1.9 0.4 311 11 310 255 4.8 0 5 4.8 10/15/2005 15:40:00 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 303 15 319 255 4.6 0 4.8 4.5 10/15/2005 15:50:00 1.4 0.3 2.3 0.4 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 302 11 295 255 4.5 0 4.8 4.5 10/15/2005 16:00:00 1.5 0.3 2.3 0.7 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 298 8 291 255 4.5 0 4.5 4.5 10/15/2005 16:10:00 1.2 0.5 2.3 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 292 11 293 255 4.4 0 4.5 4.3 10/15/2005 16:20:00 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 284 17 264 255 4.3 0 4.5 4.3 10/15/2005 16:30:00 1.2 0.3 1.9 0.7 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 296 9 297 255 4.1 0 4.3 4 10/15/2005 16:40:00 0.8 0.4 1.9 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 300 0 300 255 4 0 4 3.8 10/15/2005 16:50:00 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 300 0 300 255 3.6 0 3.8 3.5 10/15/2005 17:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 255 3.3 0 3.5 3 10/15/2005 17:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 255 2.9 0 3.3 2.8 10/15/2005 17:20:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 255 2.6 0.1 2.8 2.3 10/15/2005 17:30:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 7 14 255 2.3 0 2.6 2.1 10/15/2005 17:40:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 13 255 1.9 0.1 2.3 1.8 10/15/2005 17:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 13 255 1.7 0 1.8 1.6 10/15/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 255 255 1.6 0 1.8 1.6 10/15/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 255 255 1.4 0.1 1.6 1.4 10/15/2005 18:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 22 62 255 1.2 0 1.4 1.1 10/15/2005 18:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 71 255 0.9 0 1.4 0.9 10/15/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 255 255 0.7 0 0.9 0.7 10/15/2005 18:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 71 255 0.5 0 0.7 0.4 10/15/2005 19:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 71 255 0.3 0 0.7 0.2 10/15/2005 19:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 71 255 -0.1 0 0.2 -0.1 10/15/2005 19:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 71 255 -0.3 0 -0.1 -0.5 10/15/2005 19:30:00 1 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 72 255 -0.5 0 -0.3 -0.5 10/15/2005 19:40:00 0.8 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 71 255 -0.7 0 -0.5 -0.7 10/15/2005 19:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 72 255 -0.8 0 -0.7 -0.7 10/15/2005 20:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 72 255 -0.9 0 -0.7 -1 10/15/2005 20:10:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 72 255 -1.1 0 -1 -1.2 10/15/2005 20:20:00 1.2 0.3 1.9 0.7 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 72 0 71 255 -1.3 0 -1.2 -1.4 10/15/2005 20:30:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 72 255 -1.4 0 -1.2 -1.4 10/15/2005 20:40:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 9 74 255 -1.6 0 -1.4 -1.7 10/15/2005 20:50:00 1.4 0.2 1.9 0.7 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 97 4 100 255 -1.6 0 -1.4 -1.7 10/15/2005 21:00:00 1.8 0.2 2.3 1.1 1.1 0.3 1.9 0.7 0.4 0.1 1.1 0.4 98 2 96 255 -1.7 0 -1.7 -1.9 10/15/2005 21:10:00 1.8 0.4 2.6 1.1 1.2 0.5 2.6 0.4 0.5 0.3 1.9 0.4 114 12 121 255 -1.8 0 -1.7 -1.9 10/15/2005 21:20:00 2.1 0.4 3 1.1 1.7 0.4 2.6 0.4 0.7 0.4 1.5 0.4 119 11 126 255 -2 0 -1.9 -2.1 10/15/2005 21:30:00 2.2 0.3 3 1.5 1.7 0.4 2.6 0.7 0.7 0.3 1.5 0.4 99 7 89 255 -2.1 0 -1.9 -2.1 10/15/2005 21:40:00 2.4 0.2 3 1.9 2 0.3 3 1.1 0.8 0.3 1.5 0.4 99 4 102 255 -2.3 0 -2.1 -2.4 10/15/2005 21:50:00 2.6 0.3 3 1.9 2.2 0.3 2.6 1.5 0.9 0.4 1.9 0.4 99 5 94 255 -2.4 0 -2.1 -2.6 10/15/2005 22:00:00 2.6 0.4 3.4 1.5 2.2 0.4 3 0.7 1 0.4 1.9 0.4 106 9 104 255 -2.4 0 -2.1 -2.6 10/15/2005 22:10:00 2.8 0.4 3.8 1.9 2.5 0.4 3.4 1.5 1.2 0.5 2.3 0.4 108 9 107 255 -2.3 0 -2.1 -2.6 10/15/2005 22:20:00 2.9 0.4 3.8 1.5 2.6 0.4 3.8 1.5 1.3 0.6 2.6 0.4 110 10 115 255 -2.2 0 -2.1 -2.4 10/15/2005 22:30:00 3 0.4 3.8 1.9 2.7 0.4 3.4 1.5 1.5 0.5 2.6 0.4 106 8 101 255 -2.2 0 -2.1 -2.4 10/15/2005 22:40:00 3 0.4 3.8 1.9 2.7 0.4 3.4 1.5 1.5 0.5 2.6 0.4 106 9 111 255 -2.3 0 -2.1 -2.4 10/15/2005 22:50:00 2.9 0.4 3.8 1.5 2.6 0.5 3.8 1.1 1.3 0.4 2.3 0.4 108 11 95 255 -2 0 -1.9 -2.1 10/15/2005 23:00:00 2.5 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1 0.5 2.6 0.4 119 15 139 255 -2.3 0.1 -2.1 -2.6 10/15/2005 23:10:00 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.1 1.1 0.5 2.6 0.4 119 11 105 255 -2.4 0 -2.4 -2.6 10/15/2005 23:20:00 2.9 0.5 3.8 1.5 2.6 0.6 3.8 1.1 1.4 0.7 3.4 0.4 114 11 109 255 -2.5 0 -2.4 -2.6 10/15/2005 23:30:00 2.5 0.5 3.8 1.1 2.1 0.6 3.4 0.4 1.2 0.6 3 0.4 120 12 111 255 -2.3 0 -2.1 -2.6 10/15/2005 23:40:00 2.4 0.5 3.8 1.5 2.1 0.6 3.8 0.7 1.2 0.6 2.6 0.4 123 11 148 255 -2.5 0 -2.4 -2.6 10/15/2005 23:50:00 2.8 0.5 4.2 1.5 2.6 0.5 3.8 1.5 1.5 0.5 3 0.4 120 12 102 255 -2.6 0 -2.6 -2.8 10/16/2005 00:00:00 2.7 0.5 3.8 1.5 2.4 0.5 3.4 0.7 1.2 0.6 2.6 0.4 113 11 144 255 -2.6 0 -2.6 -2.8 10/16/2005 00:10:00 2.6 0.4 3.8 1.5 2.4 0.5 3.4 1.1 1.2 0.6 2.6 0.4 111 10 118 255 -2.6 0 -2.4 -2.6 10/16/2005 00:20:00 2.7 0.5 3.8 1.5 2.5 0.5 3.4 1.1 1.2 0.5 2.3 0.4 111 11 80 255 -2.6 0 -2.6 -2.6 10/16/2005 00:30:00 2.8 0.5 4.2 1.5 2.6 0.5 3.8 1.5 1.4 0.5 2.6 0.4 105 12 97 255 -2.6 0 -2.6 -2.6 10/16/2005 00:40:00 3.2 0.4 4.2 2.3 3 0.4 3.8 1.9 1.8 0.5 3 0.4 103 7 104 255 -2.6 0 -2.4 -2.6 10/16/2005 00:50:00 3.2 0.4 4.2 1.9 3 0.4 3.8 1.9 1.9 0.4 2.6 1.1 96 7 99 255 -2.6 0 -2.6 -2.6 10/16/2005 01:00:00 2.7 0.3 3.8 1.9 2.5 0.3 3.8 1.5 1.5 0.4 3 0.4 90 6 97 255 -2.8 0.1 -2.6 -3 10/16/2005 01:10:00 2.4 0.4 3.4 1.5 2.2 0.5 3 1.1 1.1 0.5 2.6 0.4 92 8 96 255 -3.1 0 -3 -3.5 10/16/2005 01:20:00 2.2 0.4 3.4 1.5 2 0.5 3.4 1.1 0.6 0.4 1.9 0.4 87 6 78 255 -3.3 0 -3 -3.5 10/16/2005 01:30:00 2.8 0.3 3.8 1.9 2.6 0.3 3.4 1.5 1.4 0.5 2.6 0.4 94 7 96 255 -3 0 -2.8 -3.3 10/16/2005 01:40:00 2.8 0.5 3.8 1.1 2.5 0.6 3.4 0.4 1.1 0.5 2.3 0.4 105 10 106 255 -3 0 -3 -3 10/16/2005 01:50:00 2 0.5 3 0.7 1.5 0.6 3 0.4 0.6 0.4 1.9 0.4 117 13 91 255 -3.1 0 -3 -3.3 10/16/2005 02:00:00 2.5 0.4 3.4 1.5 2.2 0.4 3 0.7 0.9 0.4 1.9 0.4 104 8 106 255 -3.2 0 -3 -3.3 10/16/2005 02:10:00 2.8 0.3 3.8 2.3 2.6 0.4 3.4 1.9 1.3 0.5 2.6 0.4 100 7 105 255 -3.2 0 -3 -3.3 10/16/2005 02:20:00 3 0.3 4.2 2.3 2.8 0.3 3.8 1.9 1.7 0.4 2.6 0.7 96 6 100 255 -3.2 0 -3 -3.3 10/16/2005 02:30:00 3 0.4 4.2 1.9 2.8 0.5 3.8 1.5 1.7 0.4 3 0.4 101 8 100 255 -3.1 0 -3 -3.3 10/16/2005 02:40:00 3.2 0.5 4.6 1.9 2.9 0.5 4.2 1.5 1.6 0.6 3.4 0.4 109 10 100 255 -3 0.1 -2.8 -3.3 10/16/2005 02:50:00 3.3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 2 0.6 3.8 0.4 108 10 108 255 -2.8 0.1 -2.4 -2.8 10/16/2005 03:00:00 3.1 0.6 4.6 1.5 2.9 0.6 4.2 1.5 1.7 0.7 3.8 0.4 109 11 104 255 -2.4 0 -2.1 -2.6 10/16/2005 03:10:00 3 0.6 4.2 1.1 2.8 0.6 3.8 0.7 1.7 0.7 3.8 0.4 109 11 100 255 -2 0 -1.9 -2.4 10/16/2005 03:20:00 3 0.6 4.6 1.5 2.8 0.6 4.2 1.1 1.5 0.6 3.4 0.4 106 12 94 255 -2.1 0 -1.9 -2.1 10/16/2005 03:30:00 2.5 0.7 4.2 1.1 2.2 0.8 4.2 0.4 1 0.6 2.6 0.4 103 12 105 255 -2.3 0.2 -2.1 -2.6 10/16/2005 03:40:00 2.3 0.4 3.4 1.5 2.1 0.4 3 1.1 0.9 0.5 2.6 0.4 103 11 89 255 -2.7 0 -2.6 -2.8 10/16/2005 03:50:00 2.3 0.4 3.4 1.1 2 0.4 3.4 1.1 0.7 0.4 1.9 0.4 101 10 109 255 -2.9 0.1 -2.6 -3 10/16/2005 04:00:00 2.7 0.6 4.2 1.5 2.4 0.6 3.8 0.7 1.1 0.5 2.6 0.4 107 12 100 255 -3.1 0 -2.8 -3.3 10/16/2005 04:10:00 2.6 0.5 4.2 1.5 2.4 0.6 4.2 0.4 1.1 0.7 3 0.4 109 12 101 255 -3 0 -2.8 -3 10/16/2005 04:20:00 2.7 0.5 3.8 1.5 2.4 0.5 3.8 0.7 1.2 0.5 2.3 0.4 100 9 107 255 -3.1 0 -3 -3.5 10/16/2005 04:30:00 2.4 0.3 3.4 1.5 2.1 0.4 3 1.1 0.9 0.4 2.3 0.4 104 8 102 255 -3.5 0 -3.3 -3.5 10/16/2005 04:40:00 2.6 0.4 4.2 1.5 2.4 0.5 3.4 0.7 1 0.6 2.3 0.4 111 10 105 255 -3.6 0 -3.5 -3.7 10/16/2005 04:50:00 2.9 0.4 3.8 1.9 2.6 0.5 3.8 1.5 1.2 0.6 3 0.4 108 13 108 255 -3.5 0 -3.3 -3.5 10/16/2005 05:00:00 2.9 0.5 4.2 1.5 2.6 0.5 3.8 1.5 1.2 0.6 3 0.4 110 11 101 255 -3.3 0 -3 -3.5 10/16/2005 05:10:00 2.9 0.5 4.6 1.1 2.6 0.6 4.2 0.7 1.3 0.7 3 0.4 107 15 118 255 -2.9 0 -2.8 -3 10/16/2005 05:20:00 3.1 0.5 4.6 1.5 2.8 0.6 4.2 1.5 1.6 0.6 3.4 0.4 106 11 86 255 -2.7 0.1 -2.4 -3 10/16/2005 05:30:00 2.9 0.5 4.2 1.1 2.7 0.5 4.2 1.1 1.6 0.6 3 0.4 105 12 102 255 -2.5 0 -2.4 -2.6 10/16/2005 05:40:00 2.7 0.5 4.2 1.5 2.5 0.5 3.8 1.1 1.3 0.6 2.6 0.4 103 14 88 255 -2.6 0 -2.4 -2.8 10/16/2005 05:50:00 1.6 0.8 3.8 0.4 1.2 0.8 3 0.4 0.6 0.5 2.6 0.4 69 27 87 255 -3.2 0 -2.8 -3.5 10/16/2005 06:00:00 0.9 0.5 3 0.4 0.5 0.4 2.3 0.4 0.4 0 0.7 0.4 76 4 37 255 -3.7 0.1 -3.5 -3.9 10/16/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 255 255 -4 0 -3.9 -4.2 10/16/2005 06:20:00 0.9 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0 0.4 0.4 82 10 95 255 -4.2 0 -3.9 -4.4 10/16/2005 06:30:00 1.4 0.6 2.6 0.4 1 0.6 2.6 0.4 0.4 0.1 0.7 0.4 88 8 97 255 -4.4 0.1 -4.4 -4.6 10/16/2005 06:40:00 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 98 16 81 255 -4.7 0 -4.6 -4.8 10/16/2005 06:50:00 1.4 0.5 3 0.4 0.8 0.4 2.3 0.4 0.4 0.1 0.7 0.4 118 10 125 255 -4.8 0 -4.6 -4.8 10/16/2005 07:00:00 1.8 0.5 3 0.4 1.4 0.6 2.6 0.4 0.6 0.4 1.9 0.4 110 12 143 255 -4.7 0.1 -4.6 -4.8 10/16/2005 07:10:00 1.6 0.4 2.6 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 111 12 109 255 -4.8 0 -4.6 -4.8 10/16/2005 07:20:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 103 10 87 255 -4.9 0 -4.6 -5 10/16/2005 07:30:00 1.5 0.5 3 0.4 1 0.6 3 0.4 0.4 0.1 1.5 0.4 114 11 99 255 -4.8 0 -4.6 -5 10/16/2005 07:40:00 2.4 0.4 3.4 1.5 2.2 0.4 3 1.1 0.9 0.5 2.3 0.4 106 12 111 255 -4.9 0 -4.8 -5 10/16/2005 07:50:00 2.3 0.5 3.4 1.1 2 0.5 3.4 0.4 1 0.5 2.6 0.4 118 15 93 255 -4.8 0 -4.6 -5 10/16/2005 08:00:00 2.3 0.4 3.8 1.5 2.1 0.5 3.4 0.7 0.9 0.5 2.3 0.4 94 9 92 255 -4.5 0 -4.4 -4.6 10/16/2005 08:10:00 2.4 0.3 3 1.5 2.1 0.3 3 1.1 1 0.4 1.9 0.4 92 5 90 255 -4.3 0.1 -3.9 -4.6 10/16/2005 08:20:00 2.7 0.5 4.2 1.1 2.4 0.6 3.8 0.4 1.3 0.6 2.6 0.4 92 11 106 255 -3.9 0.1 -3.7 -4.2 10/16/2005 08:30:00 2.4 0.6 3.8 0.7 2 0.6 3.4 0.4 1.1 0.6 2.3 0.4 96 11 88 255 -3.4 0.2 -2.8 -3.7 10/16/2005 08:40:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 93 10 86 255 -2.6 0.1 -2.4 -2.8 10/16/2005 08:50:00 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 100 11 114 255 -2.6 0 -2.6 -2.8 10/16/2005 09:00:00 1.5 0.6 3.4 0.4 1 0.7 3.4 0.4 0.6 0.4 2.3 0.4 85 10 85 255 -2.2 0.3 -1.9 -2.6 10/16/2005 09:10:00 1.7 0.4 3 0.7 1.2 0.5 2.6 0.4 0.7 0.5 1.9 0.4 92 17 115 255 -1.6 0.1 -1.2 -1.9 10/16/2005 09:20:00 1.8 0.6 3 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.3 0.4 94 13 90 255 -1 0.1 -0.7 -1.2 10/16/2005 09:30:00 1.2 0.5 3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 118 17 108 255 -0.4 0.3 0.2 -0.7 10/16/2005 09:40:00 2.5 0.6 4.2 0.7 2.1 0.7 3.8 0.4 1.9 0.8 4.2 0.4 103 15 96 255 0.2 0 0.4 0.2 10/16/2005 09:50:00 2.4 0.6 4.2 1.1 2.2 0.6 4.2 0.4 1.7 0.8 3.8 0.4 93 18 103 255 0.1 0 0.2 -0.1 10/16/2005 10:00:00 2.5 0.6 4.2 0.7 2.4 0.6 3.8 0.7 1.7 0.9 3.8 0.4 98 11 91 255 0.2 0 0.7 0.2 10/16/2005 10:10:00 1.7 0.6 3 0.4 1.5 0.6 3 0.4 1.1 0.6 2.6 0.4 101 14 113 255 0.8 0.2 1.4 0.7 10/16/2005 10:20:00 1.3 0.4 2.3 0.4 0.9 0.4 2.3 0.4 0.7 0.5 1.9 0.4 98 17 115 255 1.7 0 1.8 1.4 10/16/2005 10:30:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 99 36 37 255 1.3 0.1 1.6 0.9 10/16/2005 10:40:00 1.2 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 104 43 142 255 0.9 0 1.1 0.9 10/16/2005 10:50:00 1.6 0.4 3 0.4 1.4 0.5 2.6 0.4 1 0.5 2.6 0.4 151 26 137 255 1.2 0.2 1.8 0.9 10/16/2005 11:00:00 1.7 0.7 3 0.4 1.4 0.7 2.6 0.4 1 0.6 2.3 0.4 83 11 85 255 2 0 2.3 1.6 10/16/2005 11:10:00 1.6 0.4 2.6 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 84 11 65 255 1.9 0 2.3 1.8 10/16/2005 11:20:00 2 0.4 3 0.7 1.7 0.5 3 0.4 1.3 0.6 2.6 0.4 95 15 93 255 2.1 0.2 2.6 1.8 10/16/2005 11:30:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1 0.5 2.3 0.4 87 15 62 255 2.6 0.1 2.8 2.3 10/16/2005 11:40:00 1.6 0.4 2.6 0.4 1.3 0.5 2.6 0.4 0.8 0.5 2.6 0.4 39 18 55 255 2.5 0 2.6 2.3 10/16/2005 11:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 17 49 54 255 2.4 0 2.6 2.3 10/16/2005 12:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 40 72 18 255 2.7 0.1 2.8 2.6 10/16/2005 12:10:00 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 17 22 34 255 3.3 0.3 4 2.8 10/16/2005 12:20:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 79 58 23 255 3.8 0 4 3.8 10/16/2005 12:30:00 0.9 0.4 1.9 0.4 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 42 19 52 255 4 0 4 3.8 10/16/2005 12:40:00 1.5 0.6 3 0.4 1.5 0.5 3 0.4 0.9 0.5 2.3 0.4 342 19 43 255 3.9 0 4 3.8 10/16/2005 12:50:00 1.6 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 348 15 324 255 3.7 0 4 3.5 10/16/2005 13:00:00 1.5 0.5 2.6 0.4 1.7 0.5 3 0.4 1.3 0.5 3 0.4 311 24 297 255 3.9 0 4 3.8 10/16/2005 13:10:00 1.3 0.6 2.6 0.4 1.6 0.6 3 0.4 1 0.6 2.6 0.4 290 19 286 255 4.4 0.3 4.8 4 10/16/2005 13:20:00 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.3 2.3 0.4 293 38 307 255 5.1 0.3 5.7 4.5 10/16/2005 13:30:00 0.8 0.6 2.3 0.4 1 0.7 2.6 0.4 0.7 0.5 2.6 0.4 273 58 293 255 5.8 0.1 6 5.7 10/16/2005 13:40:00 1.5 0.5 3 0.4 1.6 0.5 3 0.4 0.9 0.6 2.3 0.4 308 26 332 255 5.9 0.1 6.2 5.7 10/16/2005 13:50:00 1 0.6 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.6 0.4 267 24 267 255 6.2 0 6.5 6.2 10/16/2005 14:00:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.5 2.3 0.4 343 22 326 255 6.2 0 6.7 6 10/16/2005 14:10:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 1.4 0.7 3 0.4 317 22 311 255 6.7 0 7 6.5 10/16/2005 14:20:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.6 3 0.4 310 22 317 255 6.4 0.1 6.7 6.2 10/16/2005 14:30:00 1.5 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 300 22 307 255 6.7 0 7 6.5 10/16/2005 14:40:00 1.6 0.5 3 0.4 1.7 0.5 3 0.4 1.2 0.5 2.3 0.4 311 17 283 255 6.5 0.2 7 6 10/16/2005 14:50:00 1.2 0.6 2.3 0.4 1.2 0.6 2.6 0.4 0.8 0.5 1.9 0.4 313 28 325 255 5.9 0.1 6.2 5.7 10/16/2005 15:00:00 1.4 0.5 2.3 0.4 1.3 0.4 2.3 0.4 0.9 0.5 2.3 0.4 331 24 300 255 5.4 0.2 6 5 10/16/2005 15:10:00 1.5 0.5 2.6 0.4 1.3 0.4 2.6 0.4 0.9 0.6 2.3 0.4 340 11 339 255 5.2 0.1 5.5 4.8 10/16/2005 15:20:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.7 0.5 2.6 0.4 326 22 308 255 4.4 0.2 5 4 10/16/2005 15:30:00 1.4 0.4 2.3 0.7 1.3 0.4 2.3 0.4 0.9 0.5 1.9 0.4 337 17 345 255 3.8 0 4.3 3.5 10/16/2005 15:40:00 1.1 0.5 2.3 0.4 1 0.4 2.3 0.4 0.6 0.4 1.5 0.4 339 12 334 255 3.6 0.1 3.8 3.5 10/16/2005 15:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 343 9 344 255 3.3 0 3.5 3 10/16/2005 16:00:00 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 330 7 317 255 2.9 0 3.3 2.6 10/16/2005 16:10:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 328 21 329 255 2.4 0 2.6 2.1 10/16/2005 16:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 348 0 348 255 2 0.1 2.3 1.8 10/16/2005 16:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 348 0 348 255 1.7 0 1.8 1.4 10/16/2005 16:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 348 0 255 255 1.1 0 1.6 0.9 10/16/2005 16:50:00 0.8 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.4 0.1 0.7 0.4 350 2 348 255 0.7 0 0.9 0.4 10/16/2005 17:00:00 1 0.3 1.9 0.4 1.2 0.3 1.9 0.7 0.4 0.1 1.1 0.4 3 2 3 255 0.5 0 0.7 0.4 10/16/2005 17:10:00 1.2 0.2 1.9 0.7 1.3 0.2 1.9 0.7 0.4 0.1 0.7 0.4 3 0 3 255 0.5 0.1 0.9 0.2 10/16/2005 17:20:00 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.4 0 0.7 0.4 7 3 3 255 0.2 0.1 0.9 -0.1 10/16/2005 17:30:00 0.7 0.4 1.5 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 8 0 9 255 -0.2 0 0.4 -0.5 10/16/2005 17:40:00 0.5 0.3 1.1 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 8 0 9 255 -0.5 0 -0.1 -0.5 10/16/2005 17:50:00 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 8 0 8 255 -0.8 0.1 -0.5 -1.2 10/16/2005 18:00:00 0.8 0.3 1.5 0.4 1.1 0.2 1.9 0.4 0.4 0 0.4 0.4 33 17 50 255 -1.2 0 -1 -1.4 10/16/2005 18:10:00 1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 55 0 55 255 -1.3 0 -1.2 -1.4 10/16/2005 18:20:00 0.9 0.3 1.5 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 55 0 55 255 -1.5 0 -1 -1.4 10/16/2005 18:30:00 0.7 0.3 1.5 0.4 1 0.3 1.9 0.4 0.4 0 0.7 0.4 61 6 55 255 -1.6 0 -1.4 -1.7 10/16/2005 18:40:00 0.9 0.2 1.5 0.4 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 68 0 68 255 -1.6 0 -1.4 -1.7 10/16/2005 18:50:00 1.2 0.3 1.9 0.7 1.5 0.3 2.3 0.7 0.5 0.2 1.1 0.4 71 6 68 255 -1.9 0 -1.7 -1.9 10/16/2005 19:00:00 1.6 0.3 2.6 0.7 1.7 0.3 2.6 1.1 0.6 0.3 1.5 0.4 95 12 100 255 -2.1 0 -1.9 -2.1 10/16/2005 19:10:00 1.9 0.3 2.6 1.1 2.2 0.3 2.6 1.5 0.9 0.4 1.9 0.4 99 8 93 255 -2.1 0 -2.1 -2.4 10/16/2005 19:20:00 1.6 0.3 2.3 0.7 1.9 0.2 2.6 1.1 0.5 0.2 1.1 0.4 98 5 105 255 -2.4 0 -2.1 -2.6 10/16/2005 19:30:00 1.7 0.2 2.3 1.1 1.9 0.2 2.6 1.1 0.6 0.3 1.5 0.4 98 6 102 255 -2.4 0 -2.1 -2.6 10/16/2005 19:40:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 0.8 0.3 1.9 0.4 88 6 88 255 -2.6 0 -2.4 -2.6 10/16/2005 19:50:00 2.1 0.3 3 1.5 2.3 0.3 3 1.1 1.3 0.4 1.9 0.4 97 6 89 255 -2.8 0 -2.6 -2.8 10/16/2005 20:00:00 2 0.3 3 1.1 2.2 0.3 3 1.5 1.2 0.4 2.3 0.4 89 6 83 255 -2.8 0 -2.6 -2.8 10/16/2005 20:10:00 2.5 0.5 3.4 1.1 2.6 0.5 3.8 1.1 1.6 0.5 3 0.4 74 10 80 255 -2.6 0 -2.4 -2.8 10/16/2005 20:20:00 2.7 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2 0.5 3.8 0.4 69 8 74 255 -2.4 0 -2.4 -2.6 10/16/2005 20:30:00 2.5 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.7 0.5 3 0.4 71 9 76 255 -2.3 0 -2.1 -2.4 10/16/2005 20:40:00 2.3 0.5 3.8 1.1 2.4 0.5 3.4 1.1 1.4 0.4 3 0.4 70 9 51 255 -2.4 0 -2.1 -2.6 10/16/2005 20:50:00 2.4 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.6 0.5 2.6 0.4 70 9 81 255 -2.1 0.1 -1.9 -2.4 10/16/2005 21:00:00 2.9 0.6 4.2 1.5 3 0.5 4.2 1.5 2 0.6 3.8 0.7 74 11 76 255 -1.7 0 -1.4 -1.9 10/16/2005 21:10:00 3.1 0.6 4.6 1.5 3.3 0.6 4.6 1.9 2.2 0.7 4.2 0.4 69 10 73 255 -1.6 0 -1.4 -1.7 10/16/2005 21:20:00 3 0.4 3.8 1.9 3 0.4 4.2 1.9 2 0.5 3.4 0.7 80 9 68 255 -1.4 0 -1.2 -1.4 10/16/2005 21:30:00 2.9 0.5 4.2 1.9 2.9 0.5 4.2 1.9 1.9 0.5 3.4 0.4 84 8 68 255 -1.7 0.1 -1.4 -1.9 10/16/2005 21:40:00 3.3 0.5 4.6 2.3 3.3 0.5 4.6 2.3 2.2 0.4 3.8 1.1 81 9 79 255 -2 0 -1.9 -2.1 10/16/2005 21:50:00 3 0.4 4.2 1.9 3 0.4 4.2 1.5 2 0.4 3 0.7 91 6 92 255 -2.3 0 -2.1 -2.6 10/16/2005 22:00:00 3 0.4 3.8 2.3 2.9 0.4 3.8 1.9 1.9 0.4 3 1.1 86 7 88 255 -2.5 0 -2.4 -2.6 10/16/2005 22:10:00 2.8 0.4 4.2 1.9 2.7 0.5 3.8 1.5 1.5 0.5 3 0.4 90 9 71 255 -2.8 0 -2.6 -3 10/16/2005 22:20:00 2.2 0.4 3.4 1.1 2 0.5 3.4 0.4 1 0.5 2.3 0.4 102 15 76 255 -3.1 0 -2.8 -3.3 10/16/2005 22:30:00 2.4 0.5 3.8 1.1 2.1 0.6 4.2 0.4 1.1 0.5 2.3 0.4 119 12 131 255 -3.3 0 -3.3 -3.5 10/16/2005 22:40:00 2.6 0.6 3.8 1.1 2.3 0.7 3.4 0.4 1.2 0.6 3 0.4 114 12 124 255 -3.3 0 -3.3 -3.5 10/16/2005 22:50:00 2.8 0.6 4.2 1.1 2.6 0.7 4.2 1.1 1.3 0.6 3 0.4 113 11 110 255 -3.2 0 -3 -3.3 10/16/2005 23:00:00 2.9 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.3 0.6 2.6 0.4 109 10 102 255 -3.1 0 -3 -3.3 10/16/2005 23:10:00 3.5 0.4 4.2 1.9 3.3 0.5 4.2 1.1 2.3 0.5 3.4 0.7 104 8 119 255 -3.1 0 -2.8 -3.3 10/16/2005 23:20:00 3.4 0.3 4.2 2.6 3.2 0.3 3.8 2.3 2.3 0.5 3.4 1.1 101 7 95 255 -2.7 0.1 -2.4 -3 10/16/2005 23:30:00 3.6 0.3 4.6 2.6 3.5 0.3 4.2 2.6 2.5 0.5 3.8 1.1 99 7 88 255 -2.6 0 -2.4 -2.8 10/16/2005 23:40:00 3.5 0.3 4.2 2.6 3.4 0.4 4.2 2.3 2.5 0.5 3.8 0.7 98 6 93 255 -2.9 0.1 -2.6 -3.3 10/16/2005 23:50:00 3.8 0.4 4.6 2.6 3.5 0.4 4.6 2.6 2.7 0.5 3.8 1.5 99 5 95 255 -2.9 0.1 -2.6 -3 10/17/2005 00:00:00 4 0.5 5.3 2.6 3.8 0.5 4.6 1.9 2.7 0.7 4.2 0.7 105 9 112 255 -2.7 0.1 -2.4 -3 10/17/2005 00:10:00 4 0.5 5.3 2.3 3.8 0.6 4.9 2.3 2.7 0.6 4.6 1.1 108 10 102 255 -2.6 0 -2.6 -2.6 10/17/2005 00:20:00 3.6 0.6 4.9 2.3 3.4 0.6 4.9 1.5 2.5 0.8 4.2 0.4 103 10 110 255 -2.5 0 -2.1 -2.6 10/17/2005 00:30:00 3 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2 0.5 3.4 0.7 95 7 95 255 -2.4 0 -2.1 -2.6 10/17/2005 00:40:00 3 0.4 4.2 1.9 2.9 0.5 3.8 1.5 1.8 0.6 3 0.4 95 9 95 255 -2.4 0 -2.4 -2.6 10/17/2005 00:50:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 0.7 1.5 0.6 3.4 0.4 91 12 93 255 -2.2 0 -2.1 -2.4 10/17/2005 01:00:00 2.2 0.4 3 1.1 2 0.4 3 0.7 0.8 0.5 1.9 0.4 88 10 77 255 -2.6 0.1 -2.1 -2.8 10/17/2005 01:10:00 2.4 0.4 3.4 1.5 2.2 0.5 3.4 1.1 1 0.5 2.3 0.4 115 10 108 255 -2.9 0 -2.6 -3 10/17/2005 01:20:00 2.6 0.6 3.8 1.1 2.5 0.6 3.8 0.7 1.4 0.6 2.6 0.4 112 15 129 255 -2.5 0.1 -2.1 -2.6 10/17/2005 01:30:00 3.3 0.5 4.6 1.9 3.2 0.6 4.6 1.9 2.3 0.5 4.2 1.1 101 8 95 255 -2.1 0 -1.9 -2.1 10/17/2005 01:40:00 3.6 0.5 4.9 2.3 3.5 0.6 4.9 2.3 2.5 0.7 4.9 0.7 93 9 93 255 -1.7 0 -1.4 -1.9 10/17/2005 01:50:00 3.9 0.6 5.3 1.9 3.8 0.6 4.9 1.5 2.7 0.7 4.2 0.7 94 9 96 255 -1.6 0 -1.4 -1.4 10/17/2005 02:00:00 3.5 0.6 4.9 2.3 3.4 0.6 4.9 1.9 2.5 0.7 4.2 0.7 97 8 96 255 -1.4 0 -1.2 -1.4 10/17/2005 02:10:00 3.4 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.2 0.8 3.8 0.4 113 12 113 255 -1.2 0.1 -1 -1.4 10/17/2005 02:20:00 3.6 0.8 4.9 1.9 3.4 0.9 4.9 1.1 2.5 0.8 4.2 0.7 114 13 117 255 -0.9 0 -0.7 -1 10/17/2005 02:30:00 4 0.8 6.1 1.9 3.8 0.8 6.1 1.9 2.9 0.8 5.7 0.7 112 15 112 255 -0.7 0 -0.5 -0.7 10/17/2005 02:40:00 3.8 0.6 5.3 2.3 3.7 0.6 5.3 2.3 2.8 0.7 4.6 0.7 105 11 101 255 -0.6 0 -0.5 -0.7 10/17/2005 02:50:00 3.7 0.7 5.3 1.5 3.6 0.7 4.9 1.9 2.6 0.8 4.6 0.7 111 13 121 255 -0.5 0 -0.5 -0.7 10/17/2005 03:00:00 3.9 0.6 5.3 1.5 3.7 0.7 5.7 1.9 2.8 0.7 4.6 0.7 110 12 105 255 -0.4 0 -0.3 -0.5 10/17/2005 03:10:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.1 2.4 0.7 4.2 0.7 107 14 112 255 -0.5 0 -0.5 -0.5 10/17/2005 03:20:00 3.2 0.6 4.6 1.5 3.1 0.6 4.6 1.1 2.2 0.7 3.8 0.4 101 9 99 255 -0.6 0 -0.5 -0.7 10/17/2005 03:30:00 4.1 0.8 6.1 2.3 4 0.8 6.1 1.9 2.9 0.7 4.9 1.1 107 10 107 255 -0.5 0 -0.3 -0.7 10/17/2005 03:40:00 4.4 0.7 5.7 1.9 4.2 0.8 5.7 2.3 3.1 0.8 5.3 1.1 105 11 102 255 -0.2 0 -0.1 -0.3 10/17/2005 03:50:00 5.1 0.9 7.2 2.3 5 0.9 7.2 2.3 4 0.9 5.7 1.1 107 11 106 255 0 0 0.2 -0.1 10/17/2005 04:00:00 4.5 0.9 6.8 2.6 4.4 0.8 6.8 2.6 3.5 1 6.8 1.1 106 13 112 255 0.3 0 0.7 0.2 10/17/2005 04:10:00 4.4 0.8 6.5 2.3 4.3 0.8 6.1 2.3 3.2 0.9 5.7 0.7 108 14 113 255 0.6 0 0.7 0.4 10/17/2005 04:20:00 4.7 1 7.6 2.6 4.5 1 7.6 2.3 3.8 1 6.5 1.5 110 13 119 255 0.7 0 0.9 0.7 10/17/2005 04:30:00 4.2 1 7.2 1.9 4.1 1.1 6.8 1.5 3.3 1.1 6.1 1.1 110 15 129 255 0.8 0 0.9 0.7 10/17/2005 04:40:00 3.7 1 6.5 1.9 3.6 1 6.5 1.5 2.4 1 5.3 0.4 99 21 101 255 0.9 0 1.1 0.9 10/17/2005 04:50:00 3.6 1 5.7 1.1 3.3 0.9 5.7 1.1 2.6 1 4.9 0.4 96 17 102 255 1.1 0 1.4 0.9 10/17/2005 05:00:00 3.5 0.9 6.1 1.5 3.3 0.9 5.3 1.1 2.7 1 4.9 0.4 100 18 83 255 1.4 0 1.6 1.4 10/17/2005 05:10:00 4.9 1.2 7.6 1.1 4.6 1.3 7.6 1.1 3.9 1.1 6.8 1.1 104 17 115 255 1.4 0 1.6 1.4 10/17/2005 05:20:00 4.9 1.1 7.2 2.3 4.7 1.1 7.2 1.9 3.9 1.1 6.5 1.1 109 15 133 255 1.4 0 1.6 1.4 10/17/2005 05:30:00 4.1 1.2 7.2 1.1 3.9 1.2 7.2 0.7 3.3 1.1 6.5 1.1 111 17 103 255 1.4 0 1.6 1.4 10/17/2005 05:40:00 5.8 1.1 8.8 2.6 5.6 1.1 8.4 2.3 4.7 1.2 7.2 1.9 102 15 108 255 1.5 0 1.8 1.4 10/17/2005 05:50:00 5.5 1.6 9.9 2.3 5.3 1.6 9.9 2.3 4.3 1.6 9.1 1.1 104 17 101 255 1.8 0 1.8 1.6 10/17/2005 06:00:00 5.6 1.4 8.8 2.6 5.5 1.4 8.8 2.6 4.6 1.5 8.4 1.5 103 16 113 255 1.8 0 1.8 1.8 10/17/2005 06:10:00 6.6 1.3 9.9 2.6 6.4 1.3 9.1 2.3 5.3 1.3 8.4 1.5 108 14 124 255 1.8 0 1.8 1.6 10/17/2005 06:20:00 6.9 1.4 10.7 3.4 6.7 1.2 10.7 3.4 5.9 1.2 9.9 3.4 114 15 101 255 1.8 0 1.8 1.6 10/17/2005 06:30:00 6.9 1.6 11.1 3.4 6.7 1.6 11.1 3 5.8 1.6 9.9 1.9 117 16 119 255 1.8 0 1.8 1.8 10/17/2005 06:40:00 7.2 1.4 11.1 3.4 7 1.3 9.9 3 6.1 1.5 9.9 2.6 109 13 135 255 1.8 0 2.1 1.8 10/17/2005 06:50:00 7.2 1.5 11.5 4.2 7.1 1.4 10.7 3.8 5.9 1.5 10.3 2.6 108 14 101 255 2.1 0 2.3 2.1 10/17/2005 07:00:00 6.7 1.5 10.7 1.9 6.6 1.5 10.7 2.3 5.5 1.2 8.8 3 103 15 105 255 2.1 0 2.3 2.1 10/17/2005 07:10:00 7 1.1 9.9 4.2 6.8 1.1 9.9 3.8 5.8 1.4 10.3 1.9 99 12 93 255 2.3 0 2.3 2.1 10/17/2005 07:20:00 6.3 1.3 9.1 3 6.2 1.3 8.8 3 5.4 1.4 8.8 2.3 100 15 73 255 2.3 0 2.3 2.3 10/17/2005 07:30:00 5.4 1.2 8.4 2.3 5.3 1.2 8.4 2.6 4.5 1.2 8.4 1.1 105 15 106 255 2.3 0 2.3 2.3 10/17/2005 07:40:00 5.4 1.1 8.4 3 5.2 1.1 8 2.6 4.3 1.1 7.2 1.9 100 17 118 255 2.4 0 2.6 2.3 10/17/2005 07:50:00 5.8 1.1 8.8 2.6 5.7 1 8.8 3 4.8 1.2 7.6 1.9 106 13 93 255 2.6 0 2.8 2.6 10/17/2005 08:00:00 5 1 8 2.6 4.8 1 7.6 2.3 3.8 1 7.2 1.1 104 15 123 255 2.8 0 2.8 2.8 10/17/2005 08:10:00 5.1 1 7.2 2.6 5 1 6.8 1.9 4.2 1.1 6.8 0.7 108 15 120 255 2.9 0 2.8 2.8 10/17/2005 08:20:00 4.2 1.1 7.2 1.5 4 1.1 6.5 1.1 3.4 1.1 6.1 0.7 99 19 95 255 2.9 0 2.8 2.8 10/17/2005 08:30:00 4.7 0.9 6.8 1.9 4.6 0.9 6.8 1.9 3.9 1 6.5 1.1 96 17 98 255 2.9 0 2.8 2.8 10/17/2005 08:40:00 3.7 0.8 6.1 1.5 3.4 0.9 5.7 1.5 2.9 1 5.7 0.4 87 20 87 255 2.9 0 3 2.8 10/17/2005 08:50:00 5.3 1.1 8.4 2.6 5 1.1 8 2.3 4.2 1.1 6.8 1.1 106 15 96 255 2.9 0 3.3 2.8 10/17/2005 09:00:00 5.6 1.5 9.1 2.3 5.5 1.5 9.1 2.6 4.7 1.5 8 1.9 103 14 100 255 3.2 0 3.3 3 10/17/2005 09:10:00 5 1.5 8.8 1.9 4.9 1.5 8.8 1.5 4.1 1.5 8.4 0.7 96 22 117 255 3 0 3.3 2.8 10/17/2005 09:20:00 6.8 2 11.5 2.3 6.6 2 11.8 1.9 5.8 2.1 11.5 0.7 98 18 106 255 2.8 0 2.8 2.6 10/17/2005 09:30:00 5.7 1.7 10.7 0.4 5.7 1.7 10.3 0.7 4.8 1.7 9.1 0.4 87 32 94 255 2.5 0.1 2.8 2.3 10/17/2005 09:40:00 4.4 1.5 8.8 1.5 4.3 1.6 9.1 1.5 3.5 1.4 7.2 0.4 68 32 83 255 2.6 0 2.6 2.6 10/17/2005 09:50:00 6.4 1.5 11.1 3.4 6.3 1.5 10.7 2.3 5.4 1.6 10.3 1.9 94 17 77 255 2.7 0 2.8 2.6 10/17/2005 10:00:00 6.3 1.3 9.9 3.8 6.2 1.3 9.5 2.6 5.3 1.3 8.8 2.6 82 19 74 255 2.9 0 3 2.8 10/17/2005 10:10:00 6 1.7 11.1 1.1 5.8 1.7 11.1 0.7 5 1.7 10.3 1.1 76 24 89 255 2.9 0 2.8 2.8 10/17/2005 10:20:00 5.6 1 8 3 5.4 1.1 8.4 2.6 4.8 1.1 7.6 1.9 84 17 88 255 2.7 0 2.8 2.6 10/17/2005 10:30:00 5.6 1.4 9.1 2.3 5.5 1.4 9.5 2.3 4.6 1.3 7.2 1.5 82 17 37 255 2.9 0.1 3.3 2.8 10/17/2005 10:40:00 6.4 1.7 10.7 2.6 6.2 1.7 10.7 2.3 5.7 1.7 10.7 1.9 86 17 110 255 2.6 0.1 3 2.3 10/17/2005 10:50:00 7 1.4 9.9 3.4 6.9 1.4 10.3 3.4 5.9 1.5 9.9 2.6 88 15 129 255 2.5 0 2.8 2.3 10/17/2005 11:00:00 6.8 1.6 11.1 3 6.7 1.6 11.8 2.6 5.6 1.6 10.7 1.9 78 16 72 255 2.8 0 2.8 2.6 10/17/2005 11:10:00 5.6 1.3 9.1 2.3 5.5 1.3 9.1 1.9 4.6 1.3 8.4 1.1 75 20 88 255 2.5 0 2.8 2.3 10/17/2005 11:20:00 6.4 1.5 11.1 3.4 6.3 1.5 11.8 3.4 5.4 1.6 11.1 1.5 82 19 91 255 2.7 0 2.8 2.6 10/17/2005 11:30:00 5.5 1.5 9.9 2.3 5.4 1.5 9.5 1.9 4.7 1.5 8.4 1.5 76 21 87 255 2.6 0 3 2.6 10/17/2005 11:40:00 7.8 1.6 12.2 3.4 7.7 1.6 11.5 3 6.2 1.8 10.7 1.5 94 17 83 255 2.6 0.3 3.3 2.3 10/17/2005 11:50:00 6.2 1.5 10.7 3 6 1.6 11.1 2.6 5.2 1.5 9.9 2.3 65 24 83 255 2.9 0.3 3.5 2.3 10/17/2005 12:00:00 6.4 1.2 9.5 3.4 6.3 1.2 9.9 3.4 5.3 1.4 8.4 0.4 63 18 62 255 3.6 0.2 4.3 3.3 10/17/2005 12:10:00 6.7 1.9 12.2 1.9 6.7 2 11.8 2.3 5.9 1.8 11.5 1.5 77 26 30 255 4.7 0.2 5 4.3 10/17/2005 12:20:00 6.8 1.5 11.8 3 6.6 1.5 11.5 3.4 5.6 1.5 9.9 2.3 93 19 97 255 5.2 0 5.5 5 10/17/2005 12:30:00 6.9 1.9 11.8 2.6 6.8 1.9 11.1 2.6 5.8 1.7 10.3 2.6 97 22 75 255 5.2 0.1 5.5 4.8 10/17/2005 12:40:00 7 1.7 12.2 2.6 6.8 1.7 11.8 2.6 6.1 1.7 10.7 1.9 104 20 85 255 5.6 0.1 6 5.5 10/17/2005 12:50:00 7.1 2 13.7 2.6 6.9 1.9 13.3 3 6 1.7 13.3 1.5 91 21 84 255 5.7 0.2 6 5 10/17/2005 13:00:00 6.7 2.3 12.6 1.5 6.5 2.3 11.8 1.9 5.3 2.2 11.1 1.1 89 24 103 255 4.8 0.2 5 4.5 10/17/2005 13:10:00 7.4 1.9 13 3.4 7.2 1.8 13 3 6.3 1.7 11.1 3.4 86 29 111 255 4.4 0 4.5 4.3 10/17/2005 13:20:00 6.9 1.7 11.5 3 6.7 1.7 10.7 3 5.8 1.7 11.1 1.9 94 20 103 255 4.3 0 4.5 4.3 10/17/2005 13:30:00 6 1.5 11.1 2.6 5.8 1.5 10.7 2.3 5.1 1.3 9.9 1.9 71 20 102 255 4.9 0.2 5 4.5 10/17/2005 13:40:00 7 1.6 12.6 3.8 6.9 1.6 11.8 3.4 5.9 1.6 11.5 2.6 91 22 108 255 4.8 0.1 5 4.8 10/17/2005 13:50:00 8.1 1.5 12.2 2.6 8 1.6 12.2 3 6.7 1.7 11.8 1.9 99 16 95 255 4.6 0 4.8 4.5 10/17/2005 14:00:00 7.6 2.2 12.2 3 7.4 2.1 12.2 3 6.6 1.9 10.7 2.3 107 16 94 255 4.2 0 4.5 4 10/17/2005 14:10:00 7.4 1.9 11.5 2.6 7.3 1.9 11.5 2.3 6.3 1.7 10.3 2.3 102 17 101 255 4.1 0 4.3 4 10/17/2005 14:20:00 7.4 1.7 11.1 3.4 7.1 1.7 11.1 3.4 6.1 1.7 10.3 2.3 93 18 100 255 4 0 4 3.8 10/17/2005 14:30:00 8 1.5 12.2 3.8 7.9 1.6 11.8 3 6.8 1.6 10.7 3 85 13 81 255 4 0 4.3 3.8 10/17/2005 14:40:00 8.3 1.7 13.7 3.8 8.2 1.7 14.5 3.8 6.9 1.7 13 3.4 81 15 61 255 4.5 0 4.8 4.3 10/17/2005 14:50:00 8.1 1.7 13 3.8 8 1.7 13 3.8 6.8 1.7 13.3 2.6 79 21 52 255 5.2 0.2 5.7 4.8 10/17/2005 15:00:00 8 2.4 15.3 4.2 7.9 2.4 15.6 4.2 6.8 2.3 14.5 2.6 66 20 45 255 5.4 0.3 6.2 5 10/17/2005 15:10:00 8.9 2 15.3 3.8 8.7 2.1 15.6 3.8 7.7 1.9 14.9 3.8 62 17 102 255 6.8 0.2 7.3 6.2 10/17/2005 15:20:00 10.7 2.8 16.8 4.9 10.7 2.8 16.8 4.9 9 2.7 16.1 3.4 52 19 31 255 7.6 0.3 8.5 7.3 10/17/2005 15:30:00 11.9 1.9 18.7 7.6 11.8 2 19.1 6.5 10.4 2.2 17.2 4.9 42 13 39 255 8.5 0 8.8 8.5 10/17/2005 15:40:00 9.7 2.9 17.2 3.8 9.6 2.9 16.8 3 8.3 2.7 15.3 3.4 55 21 57 255 8.5 0.2 8.8 7.8 10/17/2005 15:50:00 6.8 1.7 11.8 2.3 6.7 1.7 11.5 2.6 5.8 1.7 11.8 1.9 62 18 68 255 7.1 0.2 7.8 6.7 10/17/2005 16:00:00 9.6 2.8 17.9 3.8 9.4 2.8 16.8 3.4 8.1 2.8 14.9 2.3 52 21 42 255 7.6 0.6 8.5 7 10/17/2005 16:10:00 12.1 2.5 18.3 6.8 12 2.5 18.3 6.1 10.5 2.6 17.2 4.6 38 13 59 255 8.9 0 9 8.5 10/17/2005 16:20:00 12.6 2.3 19.1 6.8 12.6 2.4 19.1 6.8 10.9 2.5 17.9 6.1 39 13 20 255 8.9 0 9 8.8 10/17/2005 16:30:00 12.8 2.2 18.3 5.3 12.7 2.2 17.9 5.3 11.1 2.2 15.3 5.3 34 11 42 255 8.9 0 9 8.8 10/17/2005 16:40:00 11.9 1.9 16.8 7.2 11.9 1.9 17.2 7.6 10.1 2 14.1 5.7 34 13 18 255 8.9 0 9 8.8 10/17/2005 16:50:00 11.5 2.2 17.9 6.8 11.4 2.3 18.3 6.8 10 2.1 16.8 6.1 37 15 25 255 8.7 0 8.8 8.5 10/17/2005 17:00:00 10.6 1.9 15.3 5.7 10.5 1.9 16.1 6.1 9 2.1 15.3 4.2 39 16 40 255 8.6 0 8.8 8.5 10/17/2005 17:10:00 11.4 1.9 16.4 6.8 11.4 2 16.8 6.1 9.8 2.2 15.6 5.3 36 14 31 255 8.4 0 8.5 8.5 10/17/2005 17:20:00 12.2 2 17.9 7.2 12.2 2.1 18.3 7.2 10.6 2.2 16.8 5.7 36 14 33 255 8.3 0 8.5 8.3 10/17/2005 17:30:00 12.7 2.8 19.1 8 12.7 2.8 19.5 7.2 10.9 2.7 17.9 4.9 38 12 25 255 8.1 0.1 8.5 8 10/17/2005 17:40:00 9.3 2.6 16.4 4.6 9.3 2.7 17.2 4.2 8.3 2.5 15.6 3.8 56 17 51 255 7.6 0.5 8 6.7 10/17/2005 17:50:00 10.7 2.8 18.3 4.2 10.7 2.8 18.7 3.8 9.2 2.7 17.2 3 42 14 30 255 7.3 0.5 8.3 6.7 10/17/2005 18:00:00 11.5 2.3 18.3 4.9 11.5 2.4 18.7 4.6 9.9 2.4 17.6 3.8 41 15 34 255 8.3 0.2 8.5 8 10/17/2005 18:10:00 8.4 2.6 14.5 3.4 8.2 2.6 14.5 3 7.1 2.4 13.7 2.3 52 17 29 255 7.9 0.3 8.5 7.5 10/17/2005 18:20:00 11.7 2.5 21 4.6 11.7 2.5 20.2 4.9 10 2.4 17.2 4.2 34 11 35 255 8.1 0 8.5 7.8 10/17/2005 18:30:00 12.7 2.5 19.9 6.8 12.6 2.5 20.6 7.2 11.1 2.7 19.5 6.1 34 12 37 255 8.4 0 8.5 8.3 10/17/2005 18:40:00 10.3 1.5 14.5 5.7 10.2 1.6 15.3 6.5 9.1 1.9 14.9 4.6 36 11 56 255 8.4 0 8.5 8.3 10/17/2005 18:50:00 10.4 2.1 16.8 4.6 10.5 2.2 16.1 4.2 9.2 2.1 14.5 2.6 41 14 76 255 8.5 0 8.8 8.3 10/17/2005 19:00:00 9.4 1.9 14.1 3.8 9.3 2 14.1 3.4 8.1 1.9 13 3.4 36 15 52 255 8.3 0 8.5 8 10/17/2005 19:10:00 9.3 2.1 15.6 4.2 9.2 2.1 15.3 4.2 8.2 2.2 14.9 3.4 38 14 37 255 7.9 0 8.3 7.8 10/17/2005 19:20:00 9.5 2.1 14.5 4.6 9.4 2.2 14.9 4.2 8.4 2.3 14.1 3.8 37 13 28 255 7.8 0 7.8 7.5 10/17/2005 19:30:00 7.7 2 12.6 3.8 7.7 2.1 12.6 3.8 6.7 2.1 13 2.6 45 16 26 255 7.8 0 8 7.8 10/17/2005 19:40:00 7.3 2.1 13 3.4 7.1 2.1 12.6 3.4 5.9 1.9 9.9 2.3 8 19 347 255 7.7 0 7.8 7.5 10/17/2005 19:50:00 8.9 2.2 14.5 3.8 8.9 2.2 13.7 3.4 7.5 2.2 14.1 2.6 24 13 48 255 7.8 0 7.8 7.5 10/17/2005 20:00:00 7.5 1.3 10.3 4.2 7.4 1.3 10.7 4.6 5.8 1.3 10.3 2.6 6 18 4 255 7.7 0 7.8 7.5 10/17/2005 20:10:00 8 1.7 11.8 4.2 8 1.7 12.2 4.6 6.5 1.7 11.1 2.6 15 14 40 255 7.3 0 7.5 7 10/17/2005 20:20:00 4.7 2 8 1.1 4.7 2 8.4 1.1 3.9 1.7 7.2 1.1 26 76 30 255 6.6 0.2 7.3 6.2 10/17/2005 20:30:00 4.3 1.4 7.6 0.7 4.3 1.3 7.6 1.1 3.5 1.2 8 1.1 207 16 208 255 6 0.1 6.2 5.7 10/17/2005 20:40:00 4.3 1.1 7.2 1.5 4.4 1.1 7.2 1.5 3.2 1 6.1 0.7 206 19 214 255 5.5 0 5.7 5.2 10/17/2005 20:50:00 3.4 1.1 6.5 1.1 3.6 1.1 6.5 0.7 2.9 1 5.7 1.1 190 17 192 255 5.1 0 5.5 4.8 10/17/2005 21:00:00 2.5 0.7 5.3 1.1 2.8 0.8 5.7 1.1 2.3 0.8 4.6 0.4 184 16 174 255 4.6 0 4.8 4.5 10/17/2005 21:10:00 2.3 0.6 3.8 0.7 2.1 0.7 4.2 0.4 1.8 0.6 3.8 0.4 220 13 227 255 4.4 0 4.5 4.3 10/17/2005 21:20:00 2.6 0.6 4.6 0.7 2.7 0.6 4.6 0.4 2.3 0.6 4.2 0.7 182 17 158 255 4.1 0 4.5 3.8 10/17/2005 21:30:00 1.8 0.6 3.4 0.7 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 173 17 155 255 3.7 0.1 4 3.5 10/17/2005 21:40:00 2.2 0.6 3.8 0.7 2.2 0.6 4.2 0.7 2 0.6 4.2 0.4 159 13 134 255 3.4 0 3.5 3.3 10/17/2005 21:50:00 3.6 0.7 5.3 1.5 3.4 0.8 4.9 1.1 2.9 0.8 4.9 1.1 140 13 140 255 3 0.1 3.3 2.8 10/17/2005 22:00:00 3.8 0.7 5.7 1.9 3.7 0.7 5.3 1.5 3.1 0.7 4.9 1.1 107 13 109 255 2.5 0.1 2.8 2.3 10/17/2005 22:10:00 3.8 0.7 5.3 1.9 3.8 0.7 5.3 1.5 3 0.7 4.9 1.1 106 14 138 255 2.3 0 2.6 2.3 10/17/2005 22:20:00 4.2 0.9 6.5 1.5 4.1 1 6.5 1.5 3.5 0.8 6.1 1.9 117 14 127 255 2.3 0 2.8 2.3 10/17/2005 22:30:00 4.2 1 6.5 1.5 4.2 1 6.5 0.7 3.5 0.9 6.1 1.5 116 16 127 255 2.2 0 2.3 2.1 10/17/2005 22:40:00 3.5 1 6.1 1.1 3.4 1 6.1 1.1 2.9 1 6.1 0.7 121 19 148 255 2.1 0 2.3 2.1 10/17/2005 22:50:00 3.1 1 5.7 0.4 2.9 1.1 5.7 0.4 2.6 1 5.7 0.4 126 24 115 255 2.1 0 2.3 2.1 10/17/2005 23:00:00 2.8 1.2 5.7 0.4 2.5 1.3 5.3 0.4 2.3 1 4.6 0.4 122 22 136 255 2.2 0 2.3 2.1 10/17/2005 23:10:00 3.8 1 6.8 1.5 3.7 1 6.5 0.4 3.2 1 6.1 1.1 110 15 103 255 2.3 0 2.3 2.3 10/17/2005 23:20:00 4.3 1 6.1 1.5 4.2 1.1 6.5 1.1 3.6 1.1 6.1 0.7 100 15 79 255 2.3 0 2.3 2.3 10/17/2005 23:30:00 3.6 0.8 5.7 1.9 3.5 0.9 5.7 1.9 2.9 0.9 4.9 0.7 93 14 96 255 2.3 0 2.3 2.3 10/17/2005 23:40:00 3.8 1 6.1 1.9 3.7 1 6.5 1.5 3.1 0.9 5.3 0.7 83 16 80 255 2.3 0 2.3 2.3 10/17/2005 23:50:00 4.8 1 7.2 1.9 4.7 1 7.2 1.5 4 1 6.5 0.7 89 13 75 255 2.3 0 2.3 2.1 10/18/2005 00:00:00 3.8 0.8 5.7 2.3 3.7 0.8 5.3 2.3 3.2 0.8 4.9 1.1 91 11 77 255 2.3 0 2.3 2.3 10/18/2005 00:10:00 4.2 0.7 5.7 2.3 4.1 0.7 6.1 2.3 3.5 0.7 4.9 1.5 93 8 98 255 2.4 0 2.6 2.3 10/18/2005 00:20:00 3.3 0.8 4.9 1.5 3.2 0.8 5.3 1.1 2.5 0.7 4.2 0.7 87 11 76 255 2.5 0 2.6 2.6 10/18/2005 00:30:00 3.9 0.8 5.7 0.7 3.8 0.9 6.1 0.4 3.2 0.8 4.9 1.1 81 10 71 255 2.6 0 2.8 2.6 10/18/2005 00:40:00 2.2 1 4.2 0.4 2.2 1 4.6 0.4 1.9 0.9 4.2 0.4 93 22 68 255 2.7 0 2.8 2.6 10/18/2005 00:50:00 2.5 0.8 4.2 0.4 2.4 0.8 4.2 0.4 1.8 0.8 3.4 0.4 100 22 83 255 2.9 0 2.8 2.8 10/18/2005 01:00:00 2.1 0.7 4.2 0.4 1.9 0.7 4.2 0.4 1.5 0.7 3 0.4 132 23 112 255 2.9 0 3 2.8 10/18/2005 01:10:00 1.7 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.6 0.4 2.6 0.4 138 10 131 255 2.6 0.1 2.8 2.3 10/18/2005 01:20:00 2.9 1 4.6 0.7 2.8 1.1 4.6 0.4 2.9 0.6 4.6 1.1 122 13 96 255 2.3 0 2.6 2.3 10/18/2005 01:30:00 4 0.4 4.9 2.6 3.8 0.5 4.6 2.3 3.2 0.6 4.6 1.5 105 7 101 255 2.3 0 2.6 2.3 10/18/2005 01:40:00 3.9 0.5 5.7 2.6 3.8 0.5 5.7 2.6 3.4 0.6 4.9 1.9 99 7 88 255 2.3 0 2.6 2.3 10/18/2005 01:50:00 3.5 0.6 4.6 1.1 3.3 0.6 4.6 0.7 2.8 0.7 4.2 0.7 99 10 104 255 2.5 0 2.6 2.6 10/18/2005 02:00:00 3.4 0.6 4.9 1.5 3.2 0.7 4.9 1.1 2.6 0.7 4.2 0.7 108 11 105 255 2.6 0 2.6 2.6 10/18/2005 02:10:00 3.5 0.5 4.6 1.9 3.4 0.6 4.6 1.9 2.6 0.7 4.2 0.4 101 10 89 255 2.4 0 2.6 2.3 10/18/2005 02:20:00 3.7 0.6 4.9 1.9 3.6 0.7 4.9 1.5 2.6 0.7 4.6 0.7 112 12 112 255 2.3 0 2.6 2.3 10/18/2005 02:30:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 1.9 2.8 0.6 4.2 1.1 134 13 144 255 2.3 0 2.3 2.3 10/18/2005 02:40:00 3.5 0.6 4.9 1.9 3.3 0.6 4.9 1.5 2.8 0.6 4.6 1.1 132 16 141 255 2.4 0 2.6 2.3 10/18/2005 02:50:00 3 0.5 4.2 1.9 2.8 0.6 4.2 1.1 2.3 0.6 4.2 1.1 141 17 122 255 2.3 0 2.6 2.3 10/18/2005 03:00:00 3.5 0.6 4.9 1.5 3.3 0.7 4.9 1.1 2.6 0.6 4.2 1.1 122 12 121 255 2.3 0 2.6 2.3 10/18/2005 03:10:00 4 0.6 4.9 2.3 3.8 0.6 4.9 1.5 3.1 0.6 4.6 1.5 105 9 108 255 2.3 0 2.6 2.3 10/18/2005 03:20:00 2.7 1 4.9 0.4 2.4 1.1 4.6 0.4 1.9 0.8 4.6 0.4 125 17 121 255 2.3 0 2.6 2.3 10/18/2005 03:30:00 3.2 0.7 4.6 0.7 3 0.8 4.2 0.7 2.2 0.7 3.4 0.4 103 9 96 255 2.1 0 2.3 2.1 10/18/2005 03:40:00 1.4 1 3.8 0.4 1.1 0.9 3.4 0.4 0.7 0.5 2.6 0.4 129 15 111 255 1.8 0 2.1 1.8 10/18/2005 03:50:00 1.7 0.5 3 0.4 1.2 0.6 2.6 0.4 1 0.4 2.3 0.4 133 12 127 255 1.8 0 1.8 1.8 10/18/2005 04:00:00 2.5 0.6 3.8 1.1 2.2 0.7 3.4 0.4 1.5 0.5 2.6 0.4 117 11 119 255 1.8 0 1.8 1.8 10/18/2005 04:10:00 1.5 0.6 3 0.4 1 0.7 2.6 0.4 1 0.6 2.6 0.4 152 19 155 255 1.8 0 1.8 1.8 10/18/2005 04:20:00 2.3 0.6 3.4 0.4 1.9 0.8 3.4 0.4 1.4 0.7 3.8 0.4 134 14 144 255 1.8 0 1.8 1.8 10/18/2005 04:30:00 2.5 0.6 4.2 1.1 2.4 0.8 3.8 0.4 2.1 0.6 3.8 0.7 158 23 164 255 1.8 0 1.8 1.6 10/18/2005 04:40:00 3.5 0.4 4.2 2.3 3.3 0.4 4.2 1.9 2.8 0.5 4.2 1.5 141 9 152 255 1.9 0 2.1 1.8 10/18/2005 04:50:00 2.6 0.5 3.8 1.1 2.3 0.5 3.8 0.7 1.8 0.6 3 0.4 148 13 138 255 1.9 0 2.1 1.8 10/18/2005 05:00:00 2.7 0.6 3.8 1.1 2.5 0.6 3.8 0.7 2.1 0.6 3.4 0.4 167 19 205 255 1.9 0 2.1 1.8 10/18/2005 05:10:00 2.1 0.7 3.8 0.4 2 0.8 3.4 0.4 1.5 0.9 3.4 0.4 171 12 144 255 1.8 0 1.8 1.8 10/18/2005 05:20:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 342 79 63 255 1.8 0 2.1 1.8 10/18/2005 05:30:00 2 0.9 3.4 0.4 1.6 0.9 3 0.4 1.4 0.9 3.4 0.4 83 17 110 255 1.8 0 1.8 1.8 10/18/2005 05:40:00 1.9 0.5 3 0.7 1.5 0.6 3 0.4 1.2 0.5 2.6 0.4 87 39 92 255 1.8 0 1.8 1.6 10/18/2005 05:50:00 1.9 0.5 3 0.7 1.6 0.5 3 0.4 1 0.5 2.6 0.4 157 26 160 255 1.7 0 1.8 1.6 10/18/2005 06:00:00 0.9 0.5 2.3 0.4 0.5 0.3 2.3 0.4 0.4 0.2 1.5 0.4 98 22 117 255 1.8 0 1.8 1.6 10/18/2005 06:10:00 1.7 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.5 0.4 117 22 141 255 1.6 0 1.8 1.4 10/18/2005 06:20:00 2.6 0.4 3.4 1.5 2.3 0.4 3 1.1 1.7 0.5 2.6 0.7 146 6 156 255 1.5 0 1.6 1.6 10/18/2005 06:30:00 2.7 0.4 3.8 1.5 2.4 0.4 3.4 1.1 1.6 0.5 2.6 0.4 152 8 160 255 1.5 0 1.6 1.4 10/18/2005 06:40:00 2.9 0.4 3.8 1.5 2.7 0.4 3.4 1.1 1.9 0.4 3 1.1 157 7 160 255 1.6 0 1.6 1.4 10/18/2005 06:50:00 3.2 0.4 4.2 1.9 3 0.5 4.2 1.5 2.3 0.5 3.8 0.7 157 7 157 255 1.7 0 1.8 1.6 10/18/2005 07:00:00 3.5 0.5 4.6 2.3 3.3 0.5 4.6 2.3 2.7 0.6 4.2 1.1 161 8 162 255 1.9 0 2.3 1.8 10/18/2005 07:10:00 3.3 0.5 4.6 2.3 3 0.5 4.2 1.5 2.5 0.6 4.2 1.1 155 9 155 255 2.3 0 2.6 2.1 10/18/2005 07:20:00 3.2 0.5 4.6 2.3 2.9 0.5 4.2 1.9 2.4 0.5 3.4 1.1 152 9 150 255 2.6 0 2.8 2.6 10/18/2005 07:30:00 3.1 0.4 4.2 1.9 2.8 0.5 4.2 1.5 2.3 0.5 3.4 1.1 155 8 150 255 2.9 0 2.8 2.8 10/18/2005 07:40:00 2.7 0.5 4.2 1.5 2.4 0.5 3.8 1.1 1.8 0.6 3.8 0.4 154 11 151 255 2.9 0 2.8 2.8 10/18/2005 07:50:00 2.8 0.5 3.8 1.5 2.4 0.6 3.8 0.7 1.8 0.5 3 0.7 146 11 127 255 2.6 0 2.8 2.6 10/18/2005 08:00:00 3 0.5 4.2 1.5 2.8 0.5 3.8 1.5 2.1 0.6 3.4 0.7 139 9 127 255 2.6 0 2.8 2.6 10/18/2005 08:10:00 3 0.4 3.8 1.9 2.7 0.5 3.8 1.1 1.9 0.4 3 0.7 140 9 138 255 3 0 3.3 2.8 10/18/2005 08:20:00 2.8 0.5 3.8 1.5 2.5 0.5 3.4 0.4 1.8 0.5 3.4 0.7 137 10 106 255 3.2 0 3.5 3 10/18/2005 08:30:00 2.6 0.5 3.4 1.1 2.2 0.5 3 0.4 1.7 0.5 3 0.4 145 9 140 255 3.6 0 3.8 3.5 10/18/2005 08:40:00 2.6 0.3 3.4 1.9 2.3 0.3 3 1.5 1.8 0.4 2.6 0.7 147 6 143 255 3.5 0 3.8 3.3 10/18/2005 08:50:00 2.4 0.3 3 1.1 2 0.3 2.6 0.7 1.7 0.4 2.6 1.1 145 7 141 255 3.3 0 3.5 3.3 10/18/2005 09:00:00 3 0.4 3.8 1.9 2.7 0.4 3.4 1.1 2.2 0.5 3.4 1.1 143 8 133 255 3.4 0 3.5 3.3 10/18/2005 09:10:00 2.9 0.4 3.8 1.5 2.6 0.4 3.4 1.5 2.1 0.5 3 0.7 155 9 155 255 3.6 0 3.8 3.3 10/18/2005 09:20:00 2.6 0.5 3.4 1.5 2.3 0.5 3.4 0.7 1.8 0.5 2.6 0.4 158 9 158 255 3.8 0 4 3.5 10/18/2005 09:30:00 2.3 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1.6 0.7 3 0.4 173 14 155 255 3.8 0 4 3.5 10/18/2005 09:40:00 1 0.7 3 0.4 0.8 0.7 2.6 0.4 0.6 0.5 2.3 0.4 194 21 160 255 4.2 0 4.5 4 10/18/2005 09:50:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 191 29 106 255 4.3 0 4.5 4.3 10/18/2005 10:00:00 0.9 0.6 2.6 0.4 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 183 20 160 255 4.3 0 4.5 4.3 10/18/2005 10:10:00 1.2 0.7 3 0.4 0.9 0.6 3 0.4 0.7 0.5 2.6 0.4 191 16 196 255 4.3 0 4.5 4.3 10/18/2005 10:20:00 0.8 0.6 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.4 2.3 0.4 197 26 229 255 4.5 0 4.5 4.5 10/18/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 80 58 226 255 4.4 0 4.5 4.3 10/18/2005 10:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 23 23 255 4.3 0 4.5 4.3 10/18/2005 10:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 183 12 142 255 4.5 0.1 4.8 4.3 10/18/2005 11:00:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 187 0 187 255 4.8 0 4.8 4.8 10/18/2005 11:10:00 2.1 0.3 2.6 1.5 1.8 0.3 2.3 1.1 1.5 0.4 2.3 0.4 25 30 18 255 4.6 0 4.8 4.5 10/18/2005 11:20:00 0.5 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.9 0.4 33 2 29 255 4.8 0 5 4.5 10/18/2005 11:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 28 7 32 255 5.2 0.1 5.5 5 10/18/2005 11:40:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 17 0 17 255 5.4 0 5.7 5.2 10/18/2005 11:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 40 10 51 255 5.8 0.1 6 5.7 10/18/2005 12:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 30 15 43 255 6.1 0.1 6.2 6 10/18/2005 12:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 5 6 9 255 6.4 0 6.7 6.2 10/18/2005 12:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 357 11 0 255 6.8 0 7 6.7 10/18/2005 12:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 318 255 6.8 0 7 6.7 10/18/2005 12:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 318 255 6.9 0 7 6.7 10/18/2005 12:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 317 0 317 255 7.1 0 7.3 7 10/18/2005 13:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 257 38 241 255 7.5 0.1 7.8 7.3 10/18/2005 13:10:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 174 17 154 255 7.9 0 8 7.8 10/18/2005 13:20:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 179 14 153 255 7.9 0 8.3 7.8 10/18/2005 13:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 221 76 170 255 8.3 0 8.5 8.3 10/18/2005 13:40:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 11 4 12 255 8.2 0 8.3 8.3 10/18/2005 13:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 1 0 1 255 8.1 0.1 8.3 7.8 10/18/2005 14:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0 1 255 8 0 8.3 7.8 10/18/2005 14:10:00 1.2 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1 0 1 255 7.8 0 8 7.8 10/18/2005 14:20:00 1.2 0.2 1.9 0.7 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 357 6 348 255 7.6 0 7.8 7.5 10/18/2005 14:30:00 1.5 0.3 2.3 0.4 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0 8 354 255 7.5 0 7.8 7.3 10/18/2005 14:40:00 1.3 0.3 1.9 0.7 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 2 7 352 255 7.3 0 7.5 7.3 10/18/2005 14:50:00 1.3 0.3 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 351 7 329 255 7.1 0 7.3 7 10/18/2005 15:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 346 0 346 255 7.1 0 7.3 7 10/18/2005 15:10:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 8 12 9 255 7.3 0 7.5 7.3 10/18/2005 15:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 7 0 7 255 7.3 0 7.5 7.3 10/18/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 0 255 255 7.3 0 7.5 7.3 10/18/2005 15:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 2 7 255 7.2 0 7.3 7 10/18/2005 15:50:00 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 38 5 39 255 7 0 7.3 7 10/18/2005 16:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 44 0 44 255 6.7 0 7 6.7 10/18/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 255 255 6.6 0 6.7 6.5 10/18/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 255 255 6.4 0 6.7 6.2 10/18/2005 16:30:00 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 43 5 44 255 6.2 0 6.2 6.2 10/18/2005 16:40:00 1.1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 15 7 27 255 6.1 0 6.2 6 10/18/2005 16:50:00 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 34 16 37 255 5.8 0 6 5.7 10/18/2005 17:00:00 1.7 0.2 2.3 1.1 1.4 0.3 1.9 0.4 1 0.4 1.9 0.4 45 7 38 255 5.7 0 6 5.7 10/18/2005 17:10:00 1.9 0.2 2.3 1.5 1.6 0.2 2.3 1.1 1.1 0.4 1.9 0.4 43 8 49 255 5.7 0 6 5.7 10/18/2005 17:20:00 1.8 0.2 2.3 0.7 1.6 0.3 2.3 0.4 1.1 0.4 1.9 0.4 48 10 35 255 5.5 0 5.7 5.5 10/18/2005 17:30:00 1.4 0.5 2.6 0.4 1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 50 6 45 255 5.2 0 5.5 5 10/18/2005 17:40:00 2 0.4 3 0.7 1.7 0.4 2.6 0.7 1.4 0.5 2.6 0.4 57 12 60 255 5.1 0 5 5 10/18/2005 17:50:00 2.2 0.4 3 1.1 1.9 0.5 3 0.7 1.4 0.5 2.6 0.4 62 8 52 255 4.9 0 5 4.8 10/18/2005 18:00:00 1.5 0.3 2.3 0.7 1.2 0.3 2.3 0.4 0.5 0.3 1.5 0.4 62 9 50 255 4.4 0.1 4.8 4.3 10/18/2005 18:10:00 1.5 0.6 3.4 0.4 1.2 0.7 2.6 0.4 0.9 0.6 2.3 0.4 61 12 88 255 4.1 0 4.3 4 10/18/2005 18:20:00 1.6 0.7 3 0.4 1.3 0.8 2.6 0.4 0.9 0.6 2.3 0.4 66 11 43 255 4.1 0 4.3 4 10/18/2005 18:30:00 2.5 0.4 3.4 1.5 2.4 0.5 3.8 1.1 1.7 0.6 3 0.4 72 9 69 255 4.2 0 4.3 4 10/18/2005 18:40:00 1.9 0.4 3 1.1 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 63 11 56 255 4 0 4.3 4 10/18/2005 18:50:00 2.2 0.5 3 1.5 1.9 0.6 3 0.7 1.5 0.6 3.4 0.4 67 11 74 255 4 0 4.3 3.8 10/18/2005 19:00:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 1.1 1.8 0.6 3.4 0.7 81 11 78 255 3.6 0.1 3.8 3.5 10/18/2005 19:10:00 2.6 0.6 4.2 1.1 2.4 0.6 3.8 0.7 1.6 0.6 3 0.4 74 10 66 255 3.6 0 3.8 3.5 10/18/2005 19:20:00 2.2 0.6 3.8 1.1 2 0.6 3.8 0.7 1.3 0.6 3.4 0.4 67 13 59 255 3.3 0.2 3.8 2.8 10/18/2005 19:30:00 3 0.4 4.2 1.9 2.8 0.4 3.8 1.9 2 0.5 3.4 0.7 50 11 27 255 2.8 0 3 2.6 10/18/2005 19:40:00 2.8 0.5 3.8 1.1 2.6 0.5 3.8 1.5 2.1 0.6 3.8 0.7 69 10 71 255 2.8 0 2.8 2.6 10/18/2005 19:50:00 2.3 0.7 4.2 0.7 2.1 0.8 4.2 0.4 1.3 0.8 3.4 0.4 68 14 69 255 2.4 0.2 2.8 1.8 10/18/2005 20:00:00 0.9 0.6 2.6 0.4 0.7 0.4 2.3 0.4 0.4 0.2 1.5 0.4 79 15 84 255 1.7 0 2.1 1.6 10/18/2005 20:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 167 15 170 255 1.4 0 1.6 1.4 10/18/2005 20:20:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.4 0.1 1.1 0.4 80 69 40 255 1.3 0 1.6 1.4 10/18/2005 20:30:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 63 61 23 255 1.3 0 1.6 1.4 10/18/2005 20:40:00 1.2 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.4 1.9 0.4 176 28 209 255 1.2 0 1.4 1.4 10/18/2005 20:50:00 1.8 0.4 2.6 0.4 1.4 0.4 2.3 0.4 1.3 0.4 1.9 0.4 124 39 119 255 1.4 0 1.6 1.4 10/18/2005 21:00:00 2.3 0.6 3.4 1.1 2.1 0.5 3 0.7 1.8 0.5 2.6 0.4 167 15 163 255 1.5 0 1.6 1.4 10/18/2005 21:10:00 2 0.6 3 0.7 1.6 0.7 3 0.4 1.1 0.5 2.3 0.4 127 12 108 255 1.5 0 1.6 1.4 10/18/2005 21:20:00 2.5 0.5 3.4 1.1 2.2 0.6 3 0.4 1.5 0.6 3 0.4 103 14 110 255 1.7 0 1.8 1.6 10/18/2005 21:30:00 2.4 0.7 3.8 0.7 2.1 0.7 3.8 0.4 1.3 0.7 3 0.4 97 9 95 255 1.6 0 1.8 1.4 10/18/2005 21:40:00 1.6 0.7 3.4 0.4 1.3 0.7 3 0.4 0.6 0.3 1.5 0.4 89 21 97 255 1.5 0 1.6 1.4 10/18/2005 21:50:00 1.4 0.4 2.3 0.7 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 67 17 76 255 1.7 0 1.8 1.4 10/18/2005 22:00:00 1.3 0.3 2.3 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 114 22 113 255 1.5 0 1.6 1.4 10/18/2005 22:10:00 2.3 0.4 3.4 1.1 2 0.4 3.4 0.7 1.3 0.5 2.6 0.4 95 10 70 255 1.2 0 1.4 0.9 10/18/2005 22:20:00 1.8 0.3 2.6 0.7 1.4 0.4 2.3 0.4 0.8 0.4 1.5 0.4 82 10 95 255 0.9 0 1.1 0.9 10/18/2005 22:30:00 2 0.4 3 1.1 1.7 0.5 3 0.4 1.2 0.4 2.3 0.4 64 14 74 255 0.8 0 0.9 0.9 10/18/2005 22:40:00 1.9 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.2 0.3 1.9 0.4 50 10 42 255 0.7 0 0.9 0.4 10/18/2005 22:50:00 2.1 0.3 2.6 1.5 1.8 0.3 2.6 0.7 1.2 0.3 1.9 0.4 83 5 74 255 0.4 0 0.7 0.2 10/18/2005 23:00:00 2 0.4 3 1.1 1.7 0.4 2.6 0.7 1.1 0.4 2.6 0.4 89 10 87 255 0.5 0 0.7 0.2 10/18/2005 23:10:00 2.2 0.4 3.4 1.5 1.9 0.4 3.4 1.1 1.4 0.5 2.6 0.4 95 8 87 255 0.7 0 0.7 0.7 10/18/2005 23:20:00 2.5 0.4 3.4 1.5 2.2 0.4 3.4 0.7 1.7 0.4 2.6 0.4 94 10 89 255 0.6 0 0.7 0.7 10/18/2005 23:30:00 2 0.4 3 0.7 1.6 0.5 2.6 0.4 1 0.4 1.9 0.4 104 7 98 255 0.6 0 0.7 0.4 10/18/2005 23:40:00 2.5 0.8 4.2 1.1 2.2 0.9 4.2 0.7 1.6 0.8 3.8 0.4 120 13 118 255 0.5 0 0.7 0.2 10/18/2005 23:50:00 3.3 0.6 4.6 1.5 3.1 0.5 4.2 1.9 2.2 0.7 3.8 0.7 103 9 105 255 0.5 0 0.7 0.2 10/19/2005 00:00:00 3.4 0.5 4.6 1.5 3.2 0.5 4.2 1.5 2.5 0.5 3.4 1.1 94 6 92 255 0.5 0 0.7 0.2 10/19/2005 00:10:00 3.2 0.5 4.2 2.3 3.1 0.5 4.2 1.9 2.3 0.4 3.4 1.1 91 7 83 255 0.5 0 0.7 0.2 10/19/2005 00:20:00 2.6 0.6 4.2 1.1 2.4 0.6 3.8 1.1 1.6 0.6 3.4 0.4 89 9 66 255 0.5 0 0.7 0.2 10/19/2005 00:30:00 2.8 0.5 3.8 1.1 2.6 0.5 3.8 0.7 2 0.5 3 0.4 94 7 80 255 0.4 0 0.7 0.2 10/19/2005 00:40:00 3.6 0.4 4.9 2.3 3.5 0.4 4.9 2.3 2.7 0.5 3.8 1.5 95 9 71 255 0.9 0.3 1.6 0.4 10/19/2005 00:50:00 4.1 0.7 5.7 2.3 3.9 0.8 5.7 1.9 3 0.7 4.6 1.5 90 9 94 255 1.4 0 1.6 1.4 10/19/2005 01:00:00 4 0.6 5.7 2.6 3.9 0.6 5.3 2.3 3.1 0.6 4.6 1.5 89 9 97 255 1.6 0 1.8 1.4 10/19/2005 01:10:00 3.7 0.7 5.3 1.9 3.5 0.7 4.9 1.9 2.7 0.6 4.6 1.1 92 11 80 255 2 0 2.3 1.8 10/19/2005 01:20:00 3.6 0.6 5.7 1.5 3.4 0.6 5.3 1.5 2.5 0.6 4.6 1.1 100 12 79 255 1.9 0 2.1 1.8 10/19/2005 01:30:00 3 0.7 4.9 1.5 2.7 0.7 4.2 0.7 2 0.7 4.2 0.4 113 14 108 255 1.7 0.1 2.1 1.1 10/19/2005 01:40:00 3.4 0.8 4.9 1.5 3.2 0.8 4.9 1.5 2.4 0.9 4.9 0.4 107 13 113 255 1.2 0 1.4 1.1 10/19/2005 01:50:00 3.4 0.6 4.9 1.9 3.2 0.6 4.6 1.1 2.5 0.7 3.8 0.7 103 11 118 255 1.6 0 1.8 1.4 10/19/2005 02:00:00 3.8 0.5 5.3 1.5 3.6 0.6 4.9 1.5 2.6 0.6 4.6 1.1 106 10 115 255 1.9 0.1 2.1 1.8 10/19/2005 02:10:00 3.9 0.6 5.3 2.3 3.7 0.6 5.3 2.6 2.8 0.6 4.2 1.1 104 12 90 255 2.3 0.2 2.6 1.8 10/19/2005 02:20:00 3.6 0.9 4.9 0.4 3.4 0.8 4.9 0.7 2.8 0.8 4.6 0.7 104 15 113 255 2.8 0 2.8 2.6 10/19/2005 02:30:00 3.6 0.7 5.7 1.9 3.4 0.7 5.3 1.5 2.6 0.8 4.2 0.4 106 14 98 255 2.8 0 2.8 2.8 10/19/2005 02:40:00 4 0.8 6.1 2.3 3.9 0.8 6.1 1.5 3.1 0.8 4.9 1.1 97 12 97 255 2.9 0 3.3 2.8 10/19/2005 02:50:00 4.6 0.8 6.5 2.3 4.4 0.8 6.5 1.5 3.6 0.8 5.3 1.5 88 12 82 255 3.3 0 3.5 3.3 10/19/2005 03:00:00 4.4 0.8 6.5 2.3 4.2 0.8 6.1 1.9 3.5 0.8 5.3 1.5 88 11 82 255 3.5 0 3.8 3.5 10/19/2005 03:10:00 4.7 0.9 6.8 1.9 4.6 0.9 6.5 1.5 3.6 0.9 6.1 1.5 88 17 65 255 3.6 0 3.8 3.5 10/19/2005 03:20:00 4.6 0.8 6.8 2.6 4.4 0.8 6.1 2.3 3.5 0.9 6.1 1.9 87 13 75 255 3.6 0 3.8 3.5 10/19/2005 03:30:00 4.5 0.7 6.8 3 4.3 0.7 6.5 2.6 3.5 0.7 5.3 1.1 91 11 86 255 3.6 0 3.8 3.5 10/19/2005 03:40:00 4.2 0.9 6.5 2.3 4.1 1 6.8 1.9 3.5 0.8 5.3 1.5 93 12 94 255 3.6 0.1 3.8 3.5 10/19/2005 03:50:00 4.9 0.7 7.2 2.6 4.8 0.7 7.2 2.6 3.9 0.8 5.7 1.1 102 12 105 255 3.2 0.1 3.5 3 10/19/2005 04:00:00 4.5 0.9 6.5 1.9 4.4 0.9 6.5 1.9 3.5 1 5.7 0.4 106 14 112 255 3.2 0 3.3 3 10/19/2005 04:10:00 4.9 0.8 7.2 2.6 4.8 0.8 6.8 2.3 4.1 0.9 7.2 1.5 105 13 102 255 3.2 0 3.3 3 10/19/2005 04:20:00 4.9 1 8 2.3 4.8 1 8.4 2.6 3.8 1 8.4 1.5 100 13 86 255 3.3 0 3.5 3.3 10/19/2005 04:30:00 4.5 1 7.2 2.3 4.3 1 6.8 2.3 3.3 0.8 5.7 1.1 99 15 99 255 3.4 0 3.5 3.3 10/19/2005 04:40:00 4.6 0.7 6.8 2.6 4.4 0.8 7.2 1.9 3.7 0.8 5.7 1.9 96 11 97 255 3.4 0 3.5 3.3 10/19/2005 04:50:00 5.1 1 7.2 2.3 5 0.9 7.2 2.3 4.2 0.9 6.5 1.9 102 13 100 255 3.5 0 3.5 3.5 10/19/2005 05:00:00 5.6 0.8 8.8 3.4 5.4 0.9 8.8 2.6 4.6 0.9 7.2 2.6 99 11 65 255 3.3 0 3.5 3.3 10/19/2005 05:10:00 5.5 0.9 7.2 3 5.3 0.9 6.8 2.6 4.5 0.9 6.5 2.3 101 10 108 255 3.3 0 3.5 3.3 10/19/2005 05:20:00 5.1 0.8 6.8 2.6 4.9 0.8 6.5 2.3 4 0.8 6.1 1.9 103 12 84 255 3.2 0 3.5 3.3 10/19/2005 05:30:00 5.2 0.7 6.5 2.6 5.1 0.7 6.8 3 4.2 0.8 6.5 2.3 106 11 124 255 3.2 0 3.3 3 10/19/2005 05:40:00 5.3 0.9 7.6 3 5.2 1 8 2.6 4.1 1 6.8 1.5 108 12 103 255 3.2 0 3.3 3 10/19/2005 05:50:00 4.7 0.9 7.2 2.6 4.5 0.8 6.8 2.6 3.8 0.9 6.5 1.5 104 13 95 255 3.2 0 3.3 3.3 10/19/2005 06:00:00 5.2 0.8 7.2 3 5.1 0.8 7.2 3.4 4.3 0.8 6.1 2.3 103 13 99 255 3.2 0 3.3 3 10/19/2005 06:10:00 4.8 0.8 6.5 2.6 4.7 0.8 6.5 2.6 3.7 0.9 6.1 1.1 107 12 97 255 3.3 0 3.5 3.3 10/19/2005 06:20:00 5.1 0.8 6.8 2.6 4.9 0.8 6.5 2.6 4 0.8 6.5 2.3 107 13 119 255 3.3 0 3.3 3.3 10/19/2005 06:30:00 4.8 1 7.2 1.5 4.6 1 6.8 1.5 3.7 1 6.5 1.1 105 15 102 255 3.3 0 3.5 3.3 10/19/2005 06:40:00 5.2 0.7 7.6 3.4 5.1 0.7 7.2 3.4 4.3 0.7 6.1 2.3 105 11 90 255 3.5 0 3.8 3.3 10/19/2005 06:50:00 5.6 1 7.6 2.3 5.5 0.9 7.2 2.6 4.6 1 6.8 2.3 111 12 103 255 3.4 0 3.5 3.5 10/19/2005 07:00:00 4.5 1.1 7.2 1.1 4.3 1.1 7.2 0.7 3.6 1 6.8 1.1 105 17 113 255 3.4 0 3.5 3.3 10/19/2005 07:10:00 4 0.9 7.2 2.3 3.8 0.9 6.8 2.3 3.1 0.9 6.1 1.1 89 15 105 255 3.2 0 3.5 3 10/19/2005 07:20:00 4.5 0.9 7.2 2.3 4.4 0.9 6.8 2.3 3.8 0.8 5.7 1.9 108 9 112 255 3 0 3.3 2.8 10/19/2005 07:30:00 3.5 0.8 5.7 1.5 3.3 0.8 5.7 1.5 2.9 0.9 4.9 1.1 92 18 95 255 3.1 0 3.3 3 10/19/2005 07:40:00 4.8 1.1 8.4 2.3 4.7 1.1 8 2.3 4.1 1.2 7.6 1.1 88 24 101 255 3.4 0.2 3.8 3 10/19/2005 07:50:00 5.2 1.1 9.1 2.3 5.1 1.1 8.8 2.3 4.5 1 8 2.6 95 23 82 255 3.5 0.1 3.8 3.5 10/19/2005 08:00:00 5.2 1.1 8.8 2.6 5 1.1 8.8 1.9 4.1 1.1 8 1.9 93 20 55 255 3.6 0 3.8 3.5 10/19/2005 08:10:00 5.7 1.7 10.3 1.9 5.6 1.8 10.7 1.9 4.8 1.6 9.1 2.3 81 24 105 255 4.1 0.3 4.8 3.8 10/19/2005 08:20:00 5 1.2 8.4 1.9 4.8 1.2 8.4 1.5 4.4 1.1 8 1.5 98 19 72 255 4.3 0 4.5 4 10/19/2005 08:30:00 6 1.7 11.5 1.9 5.8 1.8 11.5 1.9 4.8 1.6 10.7 1.5 78 24 59 255 4.4 0.4 5.2 4 10/19/2005 08:40:00 6.1 1.3 9.5 2.6 6.1 1.4 9.5 2.6 5.3 1.2 9.9 2.3 75 22 82 255 5.7 0.2 6 5.2 10/19/2005 08:50:00 5.2 1.5 10.7 2.3 5.1 1.5 10.7 2.3 4.5 1.5 9.1 1.9 72 17 70 255 6.1 0 6.2 6 10/19/2005 09:00:00 5.9 1.6 10.7 3 5.8 1.7 10.7 2.6 5.1 1.5 9.9 2.3 64 21 57 255 6.4 0 6.7 6.2 10/19/2005 09:10:00 6.2 1.3 10.7 3.4 6 1.4 10.3 2.6 5.2 1.4 10.3 1.9 59 21 59 255 6.5 0 6.7 6.2 10/19/2005 09:20:00 7.3 1.6 13.7 4.2 7.2 1.7 13.3 3.8 6.1 1.7 12.2 3 63 22 44 255 6.7 0.1 7 6.5 10/19/2005 09:30:00 6.6 1.6 11.8 3.4 6.5 1.7 12.2 3 5.7 1.7 10.7 1.9 52 21 121 255 7.1 0 7.3 7 10/19/2005 09:40:00 6.7 1.9 12.2 3 6.6 1.9 11.8 3 5.7 1.7 11.5 2.3 75 20 74 255 6.9 0.3 7.3 6.5 10/19/2005 09:50:00 6.3 1.4 9.9 3 6.1 1.5 9.9 1.9 5.4 1.5 9.9 2.3 52 15 40 255 6.7 0.2 7.3 6.2 10/19/2005 10:00:00 6.7 1.3 10.7 3.4 6.6 1.3 10.7 3.8 5.8 1.3 10.3 2.6 73 15 68 255 7.3 0.1 7.8 7 10/19/2005 10:10:00 6 1.5 9.9 2.3 5.9 1.5 10.3 2.6 5 1.3 9.1 2.3 76 18 72 255 7.8 0 7.8 7.5 10/19/2005 10:20:00 5.9 1.2 9.1 2.6 5.8 1.2 8.8 2.6 5.1 1.3 8.4 2.6 70 17 37 255 7.6 0 7.8 7.5 10/19/2005 10:30:00 6.4 2 12.2 2.3 6.4 2.1 12.2 1.9 5.5 1.8 11.1 1.5 78 21 63 255 7.9 0 8.3 7.8 10/19/2005 10:40:00 6.5 1.6 10.7 3 6.4 1.6 11.1 3 5.5 1.5 9.5 1.9 82 17 61 255 8.1 0.1 8.5 7.8 10/19/2005 10:50:00 4.8 1.9 12.2 1.5 4.7 2 12.2 1.5 4.2 1.7 11.8 1.5 68 21 36 255 8.5 0 8.8 8.3 10/19/2005 11:00:00 4.8 1.2 8.8 2.6 4.6 1.2 8 2.6 4.1 1.2 7.6 1.9 79 20 93 255 8.7 0 8.8 8.5 10/19/2005 11:10:00 5.2 1.1 8.4 2.6 5 1.1 8 1.9 4.4 1.1 7.6 2.3 77 16 90 255 8.6 0.1 8.8 8.5 10/19/2005 11:20:00 4.3 1.1 6.8 1.9 4.2 1.1 6.8 1.5 3.6 1 7.2 1.5 74 17 93 255 8.4 0 8.5 8.5 10/19/2005 11:30:00 4.2 1.2 7.6 1.9 4 1.1 7.6 1.9 3.4 1.1 7.2 1.1 67 16 69 255 8.4 0 8.5 8.3 10/19/2005 11:40:00 4.9 1.1 8 1.9 4.7 1.2 7.6 1.5 4.3 1 6.8 1.5 85 21 92 255 8.4 0 8.5 8.3 10/19/2005 11:50:00 5 1.2 7.6 2.6 4.8 1.1 7.6 2.6 4.2 1.2 7.2 1.9 88 17 86 255 8.6 0 8.8 8.5 10/19/2005 12:00:00 3.9 1.4 7.6 0.4 3.8 1.4 7.6 0.7 3.2 1.3 7.6 0.4 90 22 87 255 8.2 0 8.5 8 10/19/2005 12:10:00 4.7 1.4 8.8 0.7 4.5 1.5 8.8 0.7 4 1.3 7.6 1.5 79 24 99 255 8.6 0 8.8 8.5 10/19/2005 12:20:00 5.9 1.4 9.5 3 5.8 1.5 9.9 2.6 5.2 1.3 9.1 2.6 88 15 96 255 9.2 0 9.3 8.8 10/19/2005 12:30:00 5.7 1.2 8.8 2.6 5.6 1.3 8.8 1.5 4.9 1.2 8.4 1.9 71 15 86 255 9 0.1 9.3 8.8 10/19/2005 12:40:00 5 1.1 8 2.3 4.8 1.1 8 2.3 4.1 1.1 7.6 1.1 68 17 71 255 8.7 0 8.8 8.5 10/19/2005 12:50:00 5.1 1 7.6 2.6 5 1 7.2 2.3 4.3 1 6.8 2.3 79 19 87 255 8.5 0 8.8 8.5 10/19/2005 13:00:00 5.2 1.2 8.8 1.9 5.1 1.3 9.1 2.3 4.5 1.2 8.8 2.3 74 18 68 255 8.7 0 8.8 8.5 10/19/2005 13:10:00 5 0.8 6.8 3 4.8 0.8 6.8 2.6 4.3 0.9 6.5 1.9 87 13 90 255 8.7 0 8.8 8.5 10/19/2005 13:20:00 5.9 2.1 12.2 1.5 5.8 2.1 12.2 1.9 5.1 2 11.1 1.1 55 27 35 255 9 0.6 10.3 8.5 10/19/2005 13:30:00 7.5 1.5 11.1 4.6 7.5 1.5 11.5 4.6 6.4 1.6 10.7 3 28 15 31 255 10.8 0.1 11.1 10.3 10/19/2005 13:40:00 6.5 1.5 10.3 3.8 6.5 1.5 10.7 3.4 5.5 1.5 9.5 2.3 36 17 35 255 11.1 0 11.1 10.9 10/19/2005 13:50:00 9.1 1.7 14.9 4.9 9.1 1.8 14.9 4.6 8 1.8 14.5 3.8 37 13 39 255 11 0 11.1 10.9 10/19/2005 14:00:00 8.2 1.8 12.6 4.2 8.1 1.8 12.6 3.8 7.1 1.7 11.8 3.4 28 14 26 255 10.8 0 11.1 10.6 10/19/2005 14:10:00 8.7 1.7 13.7 4.9 8.6 1.7 13.3 4.6 7.3 1.9 12.2 3 34 17 47 255 10.7 0 10.9 10.6 10/19/2005 14:20:00 8.2 1.4 13.7 4.6 8.2 1.5 13.7 3.8 7 1.5 11.5 3 34 16 32 255 10.7 0 10.9 10.6 10/19/2005 14:30:00 7.9 1.9 12.6 3.4 7.9 1.9 12.6 3.8 6.5 1.9 11.1 2.3 26 17 23 255 10.5 0 10.6 10.6 10/19/2005 14:40:00 6.7 1.7 12.6 3.4 6.5 1.7 12.6 3.4 5.4 1.8 13.3 2.3 21 16 15 255 10.3 0 10.6 10.3 10/19/2005 14:50:00 8.1 1.5 12.6 3.4 8 1.6 12.2 3.8 6.8 1.7 11.5 2.6 22 13 6 255 10.5 0 10.6 10.3 10/19/2005 15:00:00 8.9 1.6 13.3 6.1 8.9 1.7 13 5.3 7.2 1.6 11.5 3.8 20 13 18 255 10.6 0 10.6 10.6 10/19/2005 15:10:00 9.7 1.9 16.1 4.9 9.6 1.9 16.1 5.3 8 1.9 13.3 3.4 26 15 15 255 10.6 0 10.6 10.6 10/19/2005 15:20:00 9.2 2 14.1 4.2 9.1 2.1 14.1 4.2 7.6 2.2 13.3 3 22 17 14 255 10.4 0 10.6 10.3 10/19/2005 15:30:00 10 2.1 14.9 5.7 10 2.1 14.9 5.7 8.5 2.3 14.9 4.2 23 12 27 255 10.2 0 10.6 10.1 10/19/2005 15:40:00 9.8 2.5 16.1 4.6 9.8 2.5 16.4 4.6 8.2 2.3 14.1 3.8 26 15 24 255 10 0 10.3 10.1 10/19/2005 15:50:00 10.6 1.6 16.1 6.5 10.5 1.6 16.4 6.8 8.9 1.6 13.7 4.6 21 10 16 255 10 0 10.1 9.8 10/19/2005 16:00:00 10.1 2.5 17.2 4.6 10 2.6 17.2 4.6 8.6 2.6 15.6 3.8 22 11 12 255 10 0 10.1 9.8 10/19/2005 16:10:00 10 1.9 16.1 6.5 10 1.9 16.1 6.5 8.5 1.9 15.3 4.2 24 12 25 255 9.9 0 10.1 9.8 10/19/2005 16:20:00 9.2 2.1 14.5 5.3 9.1 2.2 14.5 4.6 7.6 2.2 13.3 3.4 24 13 56 255 9.8 0 10.1 9.6 10/19/2005 16:30:00 9.5 1.6 13.7 5.7 9.4 1.6 13.7 5.7 7.8 1.7 12.2 3.8 22 12 29 255 9.6 0 9.8 9.6 10/19/2005 16:40:00 8.2 2 13 3.4 8.2 1.9 13.3 3.4 7 1.8 11.5 2.3 27 13 28 255 9.5 0 9.6 9.3 10/19/2005 16:50:00 9.8 1.7 14.1 4.9 9.7 1.8 14.5 5.3 8.4 1.8 14.1 4.9 33 12 40 255 9.6 0 9.6 9.6 10/19/2005 17:00:00 8.7 1.7 13.3 5.3 8.6 1.7 13 4.9 7.5 1.7 11.8 3.4 30 13 32 255 9.4 0 9.6 9.3 10/19/2005 17:10:00 8.5 1.3 12.2 5.7 8.5 1.4 12.6 5.3 7.2 1.7 11.5 3.4 27 15 26 255 9.1 0.1 9.3 8.8 10/19/2005 17:20:00 8.8 1.5 13.3 4.9 8.8 1.5 13.3 4.9 7.7 1.6 13 4.6 22 11 12 255 8.8 0 9 8.5 10/19/2005 17:30:00 9.3 1.4 13 6.1 9.3 1.4 12.6 6.1 7.8 1.8 13.3 3.8 23 12 14 255 8.5 0 8.8 8.5 10/19/2005 17:40:00 9.1 1.7 13 4.6 9.1 1.7 12.6 4.6 7.9 1.8 12.6 3.8 35 14 47 255 8.8 0 9 8.5 10/19/2005 17:50:00 7.4 2.4 14.1 3 7.3 2.4 13.7 3 6.4 2.2 11.8 1.9 30 12 36 255 8.9 0 9 8.8 10/19/2005 18:00:00 7.3 1.7 12.2 3.4 7.2 1.7 12.2 3.4 6.1 1.7 11.5 2.3 36 17 21 255 8.9 0 9 8.8 10/19/2005 18:10:00 8.4 2 14.1 4.6 8.4 2 14.1 4.6 7.2 2.1 13.7 3 41 15 50 255 9.1 0 9.3 8.8 10/19/2005 18:20:00 6.2 1.6 10.3 3.4 6 1.7 11.5 2.6 5.4 1.7 10.3 2.6 79 27 58 255 8.9 0.3 9.3 8.3 10/19/2005 18:30:00 4.9 1.2 8.8 2.3 4.7 1.2 8.8 2.3 4 1.3 9.1 0.7 83 26 49 255 7.6 0.2 8.3 7.3 10/19/2005 18:40:00 7.2 1.6 11.1 3.4 7.2 1.6 10.7 3 6.2 1.7 10.3 2.6 43 15 40 255 8.5 0.3 9 7.8 10/19/2005 18:50:00 5.5 1 8.8 2.6 5.5 1 8.8 3.4 4.7 1.3 8.4 1.5 45 17 36 255 8.9 0 9 8.8 10/19/2005 19:00:00 6.3 1.5 11.1 2.6 6.2 1.5 11.1 2.3 5 1.5 9.5 1.5 28 16 29 255 8.6 0 8.8 8.5 10/19/2005 19:10:00 6 1.7 9.5 1.9 5.9 1.7 9.9 2.3 5.2 1.7 8.8 1.9 52 26 26 255 8.6 0 9 8.5 10/19/2005 19:20:00 5 1.7 9.9 2.3 4.8 1.8 9.9 1.9 4 1.6 9.1 1.1 72 18 62 255 8.5 0 8.8 8.3 10/19/2005 19:30:00 4.3 1.1 6.8 1.5 4.2 1.2 6.8 1.1 3.6 1 6.1 1.1 91 20 43 255 7.8 0.3 8.5 7.3 10/19/2005 19:40:00 3.4 0.8 5.7 1.5 3.3 0.9 5.7 1.1 2.8 0.9 5.3 1.1 85 18 88 255 7.3 0 7.5 7.3 10/19/2005 19:50:00 5.6 1.5 10.3 2.6 5.5 1.5 9.9 2.6 4.4 1.2 9.1 1.9 67 20 28 255 7.3 0 7.5 7.3 10/19/2005 20:00:00 6 1.9 11.5 2.6 5.9 1.9 11.5 2.3 5 1.6 9.1 1.9 74 16 69 255 7.7 0.1 8 7.5 10/19/2005 20:10:00 5.8 1.1 9.1 3.4 5.7 1.1 9.1 3 4.9 1.2 9.5 2.3 70 18 55 255 7.4 0 7.5 7.3 10/19/2005 20:20:00 5.5 1.9 12.2 2.6 5.4 2 12.6 1.9 4.2 1.7 10.7 1.1 72 22 22 255 7.1 0.1 7.5 7 10/19/2005 20:30:00 8.9 1.5 14.5 5.7 8.9 1.6 14.5 5.7 7.7 1.7 13.7 4.2 40 12 49 255 8.6 0.4 9 7.5 10/19/2005 20:40:00 7.2 2.1 11.1 3 7.2 2 11.8 3 6.2 1.8 11.5 2.6 56 19 31 255 9 0 9.3 8.5 10/19/2005 20:50:00 7.5 1.3 10.7 3.4 7.3 1.3 11.5 3.4 6.1 1.3 9.1 2.3 49 15 37 255 8.7 0 9 8.5 10/19/2005 21:00:00 6.9 1.2 10.3 3.8 6.9 1.3 9.9 3.4 5.9 1.3 9.1 3 55 15 52 255 8.9 0 9 8.8 10/19/2005 21:10:00 4.4 1 6.8 1.9 4.2 1 6.8 1.9 3.6 1 6.1 1.5 100 17 84 255 8 0.6 9 7.3 10/19/2005 21:20:00 4.2 1.3 7.2 1.5 4.1 1.3 7.2 0.7 3.3 1.1 6.1 0.7 98 14 98 255 6.9 0.2 7.3 6.7 10/19/2005 21:30:00 4.5 1.1 7.6 1.5 4.4 1.1 7.2 1.9 3.8 1 6.8 1.5 94 19 66 255 6.9 0 7.3 7 10/19/2005 21:40:00 5.7 1.3 9.1 2.6 5.7 1.3 9.1 3 4.7 1.3 8.8 1.9 57 17 60 255 7.5 0.4 8.3 7 10/19/2005 21:50:00 6.8 1.5 10.7 3 6.8 1.6 10.7 2.3 5.8 1.5 9.5 1.9 51 17 44 255 8.3 0.1 8.5 8 10/19/2005 22:00:00 5.9 1.1 8.8 2.6 5.9 1.1 8.4 2.6 5 1.2 8.8 2.3 66 17 29 255 8 0.2 8.5 7.8 10/19/2005 22:10:00 5.5 1.2 8.8 3 5.4 1.2 8.8 3 4.8 1.3 8 2.3 74 16 70 255 7.9 0 8 7.8 10/19/2005 22:20:00 5.1 1.1 8 2.6 5 1.1 7.6 2.3 4.4 1 6.5 1.9 97 14 78 255 7.3 0.3 7.8 6.7 10/19/2005 22:30:00 5 1.3 8 1.1 4.8 1.3 8 1.5 4 1.2 7.2 1.5 105 15 118 255 6.4 0.2 7 6.2 10/19/2005 22:40:00 5.9 0.9 8.4 3 5.8 1 8.4 2.6 4.7 1 7.6 2.3 109 14 116 255 6.3 0 6.5 6 10/19/2005 22:50:00 5.3 1.2 9.1 2.6 5.2 1.2 9.1 2.6 4.4 1.3 8 1.1 100 18 84 255 6.4 0 6.7 6.2 10/19/2005 23:00:00 6.5 1.3 9.5 3 6.4 1.3 9.1 2.6 5.5 1.2 8.8 2.6 102 20 108 255 6.8 0.1 7 6.5 10/19/2005 23:10:00 5.4 1.4 9.1 2.6 5.3 1.5 9.5 2.6 4.3 1.3 8 1.5 90 16 67 255 6.9 0 7.3 6.7 10/19/2005 23:20:00 6 1.2 9.1 2.6 5.9 1.3 8.8 2.6 4.9 1.2 8 1.9 75 14 51 255 7.1 0 7.3 7 10/19/2005 23:30:00 5.5 1.3 10.7 3 5.4 1.3 10.7 2.6 4.4 1.2 8 1.9 59 17 64 255 7.4 0.2 7.8 7 10/19/2005 23:40:00 8.9 1.5 13.3 4.6 8.9 1.5 12.6 4.9 7.7 1.5 12.2 3.8 44 14 36 255 8.7 0.4 9 7.8 10/19/2005 23:50:00 6.9 1.9 11.5 2.6 6.9 2 11.5 2.3 5.8 1.7 10.3 2.6 65 19 77 255 8.9 0.1 9.3 8.5 10/20/2005 00:00:00 5.7 1.4 8.8 2.3 5.6 1.5 8.4 2.6 4.6 1.3 7.6 1.1 82 17 87 255 8 0.1 8.5 7.8 10/20/2005 00:10:00 5.6 1.1 9.9 3 5.5 1.1 10.3 3 4.7 1.1 8.4 2.3 77 14 74 255 7.8 0 7.8 7.8 10/20/2005 00:20:00 6.2 1 8.8 3.8 6.2 1.1 9.1 3.4 5 1.2 8 1.9 84 15 61 255 7.8 0 8 7.5 10/20/2005 00:30:00 5.6 1 8 2.6 5.4 1.1 8 2.6 4.8 1.1 7.2 1.5 70 17 100 255 8.1 0 8.5 7.8 10/20/2005 00:40:00 5.7 1.2 8.4 3 5.6 1.1 8.8 2.6 5 1.1 8 2.6 99 15 96 255 8 0 8.3 7.8 10/20/2005 00:50:00 5.3 1.1 8 2.3 5.1 1.1 8 2.6 4.4 1 6.8 1.9 103 15 96 255 7.3 0.2 7.8 7 10/20/2005 01:00:00 5 1.1 8 2.3 5.1 1.1 8 2.6 4.4 1 7.2 1.9 96 17 111 255 7 0 7.3 6.7 10/20/2005 01:10:00 5.6 1.3 8.8 0.7 5.5 1.3 8.8 0.4 4.7 1.2 6.8 1.9 107 15 113 255 7.1 0 7.3 7 10/20/2005 01:20:00 6.4 1.2 10.3 2.6 6.3 1.2 9.9 2.3 5.2 1.2 8.4 2.3 110 12 123 255 7 0 7.3 7 10/20/2005 01:30:00 5.8 1.3 9.5 3 5.7 1.3 9.1 2.6 4.8 1.3 8.4 1.5 109 16 106 255 6.9 0 7.3 6.7 10/20/2005 01:40:00 4.9 1.2 8 1.1 4.7 1.3 7.6 0.4 3.9 1.2 7.2 0.7 103 19 103 255 6.6 0 7 6.5 10/20/2005 01:50:00 5.4 1.2 9.9 2.6 5.4 1.2 10.3 3 4.5 1.3 7.6 1.9 104 17 108 255 6.6 0 6.7 6.5 10/20/2005 02:00:00 5.3 1 8 3 5.2 1 7.6 2.6 4.2 1 7.2 1.5 98 15 100 255 6.7 0 7 6.7 10/20/2005 02:10:00 5.8 1.2 9.1 2.6 5.7 1.2 8.8 2.3 5 1.2 8.8 2.3 92 15 90 255 6.8 0.1 7.3 6.7 10/20/2005 02:20:00 6.5 1.5 9.9 1.9 6.4 1.5 9.9 1.5 5.4 1.5 8.8 1.5 63 15 38 255 7.8 0.2 8.3 7.3 10/20/2005 02:30:00 6 1.4 11.5 3 5.9 1.5 11.8 3 5.1 1.5 11.8 2.6 71 16 54 255 7.6 0.3 8.3 7.3 10/20/2005 02:40:00 5.6 1.6 11.8 2.6 5.4 1.6 11.8 2.3 4.5 1.5 10.7 1.5 61 20 18 255 7.5 0.1 7.8 7.3 10/20/2005 02:50:00 5.2 1.3 9.5 2.6 5 1.3 9.9 1.9 4.2 1.3 8 1.5 68 16 83 255 7.4 0 7.5 7.3 10/20/2005 03:00:00 5.5 2 11.8 1.9 5.3 2.1 11.5 1.5 4.7 2 10.7 1.9 59 22 39 255 7.4 0.1 7.8 7.3 10/20/2005 03:10:00 8.3 1.7 12.6 3.8 8.3 1.7 12.6 4.9 7.2 1.8 12.2 3 38 14 40 255 8.5 0.4 9 7.8 10/20/2005 03:20:00 9.1 1.7 13 4.6 9.1 1.8 13.3 4.6 8 1.7 13 4.2 41 12 41 255 9.2 0 9.3 9 10/20/2005 03:30:00 9 1.7 13.7 4.6 9 1.7 13.3 4.2 7.9 1.7 12.2 3.4 41 14 39 255 9.4 0 9.6 9.3 10/20/2005 03:40:00 7.8 1.7 11.8 3.8 7.8 1.7 11.8 3.8 6.5 1.6 10.7 3 50 18 35 255 9.4 0 9.6 9.3 10/20/2005 03:50:00 4.8 1 8.4 1.9 4.6 1 7.6 2.3 3.9 1 7.2 1.5 95 22 73 255 8.5 0.6 9.6 7.5 10/20/2005 04:00:00 3.7 1.1 8 1.1 3.6 1.2 7.6 0.4 3.3 1 6.5 1.5 88 20 77 255 7.5 0 7.8 7.3 10/20/2005 04:10:00 4.7 1.2 7.6 1.9 4.6 1.2 7.6 1.5 4.1 1.1 7.2 1.5 97 16 92 255 7.6 0 7.8 7.5 10/20/2005 04:20:00 4.4 1.3 7.6 2.3 4.3 1.3 7.6 1.9 3.7 1.2 7.2 1.1 90 17 100 255 7.6 0.1 7.8 7.3 10/20/2005 04:30:00 4.4 1.2 7.2 1.1 4.4 1.3 6.8 0.4 3.8 1.3 6.8 0.4 77 17 87 255 7.8 0 8 7.5 10/20/2005 04:40:00 4 1.2 7.2 0.7 4 1.1 6.8 0.7 3.5 1 6.5 1.1 73 22 68 255 8.1 0 8.3 8 10/20/2005 04:50:00 3.9 0.7 5.7 2.3 3.8 0.7 6.1 1.5 3.3 0.8 5.3 1.5 81 13 71 255 8 0 8.3 7.8 10/20/2005 05:00:00 4.3 1 6.5 1.1 4.3 1 6.5 0.7 3.6 1 6.1 0.7 83 17 74 255 7.9 0 8.3 7.8 10/20/2005 05:10:00 4.2 0.9 6.8 1.9 4.1 0.9 6.8 1.9 3.6 0.8 6.1 1.5 88 15 93 255 8.1 0 8.3 8 10/20/2005 05:20:00 4.2 1 6.8 1.9 4 1 6.5 1.5 3.4 0.9 6.5 1.5 112 17 101 255 7.8 0.3 8.3 7.3 10/20/2005 05:30:00 4.2 1.1 7.2 1.1 4.2 1.1 7.6 1.1 3.5 1.1 6.5 0.7 107 17 105 255 7.1 0 7.3 7 10/20/2005 05:40:00 4.6 1.2 7.2 0.7 4.5 1.1 7.6 0.7 3.8 1 6.5 0.7 104 15 88 255 7 0 7.3 7 10/20/2005 05:50:00 4.4 1 7.2 1.9 4.3 1 6.8 2.3 3.7 1 6.8 1.5 107 17 116 255 6.9 0 7.3 6.7 10/20/2005 06:00:00 4.9 1.3 8.8 1.5 4.8 1.3 8.8 1.9 4.2 1.1 7.6 1.9 111 14 111 255 6.7 0 7 6.7 10/20/2005 06:10:00 4.8 1.1 8 2.3 4.8 1.1 8.4 2.3 3.9 1.1 7.6 1.5 110 15 121 255 6.5 0 6.7 6.2 10/20/2005 06:20:00 5.7 1.3 8.4 2.3 5.7 1.3 9.1 1.9 4.8 1.2 8 1.5 108 13 87 255 6.6 0 6.7 6.5 10/20/2005 06:30:00 5.9 1.1 8.8 2.6 5.8 1.1 8.4 3 4.9 1.2 7.6 1.9 106 12 123 255 6.5 0 6.7 6.2 10/20/2005 06:40:00 5.2 1 8 2.6 5.2 1 8.4 3 4.5 1 7.2 1.9 105 14 122 255 6.4 0 6.7 6.2 10/20/2005 06:50:00 5.3 0.8 7.2 3 5.2 0.8 7.2 3 4.2 0.9 6.8 2.3 102 14 130 255 6.3 0 6.5 6.2 10/20/2005 07:00:00 4.9 1.2 8 1.9 4.8 1.2 8 1.9 3.9 1.1 6.5 1.5 89 13 81 255 6.6 0.2 7 6.2 10/20/2005 07:10:00 4.7 0.7 6.5 3 4.7 0.7 6.5 2.6 4 0.8 6.5 1.9 85 14 86 255 7.1 0 7.3 7 10/20/2005 07:20:00 4.6 1 8 2.6 4.5 1.1 8 2.3 3.8 1 6.8 1.9 85 18 108 255 7.1 0 7.3 7 10/20/2005 07:30:00 4.9 1.5 8.4 0.7 4.9 1.5 8.8 0.7 4 1.2 6.8 0.7 86 22 66 255 7.6 0.2 7.8 7.3 10/20/2005 07:40:00 5.1 1.3 8 1.5 5.1 1.2 7.6 1.9 4.2 1.2 8 0.7 93 17 49 255 7.6 0 7.8 7.5 10/20/2005 07:50:00 5 1.2 8.4 1.5 4.9 1.2 8.8 1.5 4.2 1.1 6.8 1.9 98 15 114 255 7.4 0.1 7.8 7.3 10/20/2005 08:00:00 5.3 1.1 8.8 2.3 5.1 1.1 8.4 1.9 4.4 1.1 7.2 1.9 103 15 88 255 7.1 0 7.3 7 10/20/2005 08:10:00 5.4 0.9 7.6 2.6 5.3 1 7.6 2.3 4.7 1.1 6.8 1.9 104 12 92 255 6.7 0 7 6.7 10/20/2005 08:20:00 5.1 1.1 8 2.3 5.1 1 7.6 2.3 4.2 1 7.6 2.3 107 15 113 255 6.7 0 6.7 6.7 10/20/2005 08:30:00 4.8 1 7.6 2.6 4.7 1 7.6 2.6 3.9 0.9 6.1 1.9 109 16 108 255 6.7 0 7 6.7 10/20/2005 08:40:00 4.8 0.8 7.2 2.6 4.7 0.8 6.8 2.3 3.9 0.9 6.5 1.5 115 13 109 255 6.9 0 7 6.7 10/20/2005 08:50:00 5 0.8 6.8 2.3 4.9 0.9 6.8 2.6 4 0.9 6.1 1.9 112 11 104 255 7.1 0 7.3 7 10/20/2005 09:00:00 5.2 1.1 6.8 1.9 5.2 1 7.2 2.6 4.2 1.1 7.2 1.9 114 13 106 255 7.2 0 7.3 7.3 10/20/2005 09:10:00 5.1 1.1 8 2.3 5.1 1.2 8 1.9 4.1 1 6.8 1.9 111 15 113 255 7.2 0 7.3 7 10/20/2005 09:20:00 5 1 7.6 3 4.9 1 7.6 2.6 4 1 6.5 1.5 110 15 110 255 7.3 0 7.3 7.3 10/20/2005 09:30:00 4.8 1 7.2 2.3 4.6 1 6.8 1.9 4 1 6.5 1.9 104 15 103 255 7.2 0 7.3 7.3 10/20/2005 09:40:00 4.6 1 7.6 2.6 4.5 1 7.6 1.9 3.7 0.9 6.5 1.5 108 12 99 255 7.3 0 7.5 7.3 10/20/2005 09:50:00 5.2 0.9 7.2 2.6 5.1 0.9 7.6 2.3 4.4 0.9 6.8 1.9 104 11 96 255 7.6 0 7.8 7.5 10/20/2005 10:00:00 5 1.1 8 1.9 4.9 1.1 7.6 2.3 4.3 1.1 7.2 1.5 103 12 104 255 7.9 0 8 7.8 10/20/2005 10:10:00 5.4 1 8 3.4 5.3 1 8 2.3 4.7 1 7.6 2.6 103 15 107 255 8.1 0 8.3 8 10/20/2005 10:20:00 4.7 0.9 6.8 2.3 4.7 0.8 6.5 2.3 3.9 0.9 6.8 1.1 96 13 88 255 8.2 0 8.5 8.3 10/20/2005 10:30:00 4.6 1 7.2 2.3 4.5 1 7.2 2.3 3.9 0.9 6.5 1.5 99 13 96 255 8.4 0 8.5 8.3 10/20/2005 10:40:00 4.9 1 7.6 1.5 4.8 1 7.6 1.9 4 1 6.8 1.5 101 12 113 255 8.5 0.1 8.8 8.5 10/20/2005 10:50:00 4.5 0.9 6.8 2.3 4.3 1 7.2 2.3 3.9 1 6.8 1.9 100 12 100 255 8.9 0 9 8.8 10/20/2005 11:00:00 3.9 0.8 6.1 2.3 3.8 0.8 5.7 1.9 3.3 0.8 5.3 1.1 98 12 99 255 8.9 0 9 8.8 10/20/2005 11:10:00 4.6 1 8 2.6 4.5 1 8 2.6 3.9 1 6.8 1.9 105 13 120 255 8.9 0 9 8.8 10/20/2005 11:20:00 5.7 1.2 8.8 3 5.5 1.2 8.4 2.6 5 1.1 8 2.3 107 15 86 255 8.9 0 9 8.8 10/20/2005 11:30:00 5.8 1.5 9.1 2.3 5.7 1.5 9.5 2.3 5 1.4 9.1 1.5 103 16 95 255 8.7 0 9 8.5 10/20/2005 11:40:00 5.8 1.3 8.8 2.3 5.8 1.3 9.1 2.6 4.9 1.2 8.8 2.3 96 15 84 255 8.5 0 8.5 8.5 10/20/2005 11:50:00 6.4 1.5 9.5 3 6.2 1.5 10.3 2.3 5.5 1.4 9.1 2.6 96 14 93 255 8.7 0 8.8 8.5 10/20/2005 12:00:00 5.6 1.2 8.4 2.6 5.6 1.2 8.4 2.6 4.7 1.3 8 0.4 95 16 90 255 9 0 9 8.8 10/20/2005 12:10:00 6 1.2 9.9 3 6 1.2 9.5 3.4 5.3 1.2 9.1 2.6 97 11 92 255 9.1 0 9.3 9 10/20/2005 12:20:00 5.9 1.1 8.8 3.4 5.8 1.1 8.8 3.4 5.1 1 8 2.6 98 14 90 255 9.4 0 9.3 9.3 10/20/2005 12:30:00 5.4 1.2 9.1 2.3 5.3 1.2 8.8 2.6 4.7 1 6.8 2.6 100 12 99 255 9.4 0 9.6 9.3 10/20/2005 12:40:00 5.6 1.2 8.8 2.3 5.6 1.2 8.8 3 4.6 1.2 8.4 1.9 104 15 124 255 9.5 0 9.6 9.3 10/20/2005 12:50:00 4.4 1.3 7.6 0.4 4.4 1.2 7.6 0.4 3.6 1.1 6.8 0.7 94 17 98 255 9.8 0 10.1 9.6 10/20/2005 13:00:00 5.5 1.4 8.4 2.3 5.4 1.4 8.4 1.5 4.6 1.3 7.6 1.5 99 17 104 255 10 0 10.1 9.8 10/20/2005 13:10:00 5.7 1.4 8.8 2.3 5.6 1.4 9.5 2.3 4.8 1.4 8 1.9 104 13 96 255 9.9 0 10.1 9.8 10/20/2005 13:20:00 5.4 1.2 7.6 2.3 5.3 1.2 7.6 1.5 4.6 1.1 7.2 1.9 104 13 115 255 10 0 10.1 9.8 10/20/2005 13:30:00 4.7 1.2 9.5 2.3 4.6 1.2 9.5 2.3 4.1 1.1 7.6 1.9 106 16 89 255 10 0 10.1 9.8 10/20/2005 13:40:00 5 1.2 8 1.9 4.9 1.2 7.6 1.1 4.2 1.1 7.2 1.1 108 15 112 255 10 0 10.1 9.8 10/20/2005 13:50:00 4.6 1.1 7.2 2.3 4.4 1.1 7.2 1.5 3.8 1 6.8 1.5 106 14 118 255 10 0 10.1 9.8 10/20/2005 14:00:00 5.2 1.2 8 1.9 5 1.2 7.6 1.1 4.3 1.1 6.8 1.9 110 17 118 255 10 0 10.1 9.8 10/20/2005 14:10:00 4.8 1.3 8.4 1.9 4.7 1.3 8.4 1.9 4.1 1.3 8 1.5 108 17 107 255 10.2 0 10.3 10.1 10/20/2005 14:20:00 4.6 1 7.6 1.9 4.5 1.1 6.8 1.9 4 1 6.8 1.9 104 15 118 255 10.2 0 10.3 10.1 10/20/2005 14:30:00 4.7 1.1 7.2 1.9 4.6 1 7.2 1.5 4.3 1 6.8 1.5 108 17 100 255 10 0 10.1 9.8 10/20/2005 14:40:00 4.6 1.1 7.6 2.3 4.4 1.1 7.6 1.9 3.9 1.1 6.8 1.5 111 16 115 255 10.2 0 10.3 10.1 10/20/2005 14:50:00 5.2 1.2 8.4 2.6 5.2 1.2 8.8 2.3 4.3 1.2 7.6 1.9 99 14 117 255 10.3 0 10.6 10.3 10/20/2005 15:00:00 4.7 1.2 7.6 1.9 4.6 1.2 7.6 1.5 3.9 1.2 7.6 1.5 96 17 71 255 10.5 0 10.6 10.3 10/20/2005 15:10:00 4.7 1.2 8 2.3 4.6 1.2 8 1.9 4 1.2 7.6 0.7 87 16 113 255 10.3 0 10.6 10.1 10/20/2005 15:20:00 4.3 1.3 6.8 1.1 4.1 1.3 7.2 0.7 3.7 1.1 6.5 0.7 89 15 119 255 9.9 0 10.1 9.6 10/20/2005 15:30:00 4.7 1.5 8.4 1.9 4.5 1.5 8 1.5 3.9 1.5 8 1.1 92 16 110 255 9.8 0 9.8 9.6 10/20/2005 15:40:00 4.8 1 7.6 1.9 4.7 1 7.6 2.3 4.1 1 6.8 1.5 90 16 86 255 9.6 0.1 9.8 9.6 10/20/2005 15:50:00 5 1.1 8 2.3 5 1.1 8 2.3 4.3 1 7.2 1.9 81 14 79 255 9.5 0 9.6 9.6 10/20/2005 16:00:00 4.8 1.3 8.8 1.9 4.8 1.3 9.1 2.3 3.9 1.2 6.8 1.1 84 17 82 255 9.6 0 9.8 9.6 10/20/2005 16:10:00 4.8 1.1 7.6 2.6 4.7 1.2 8.4 1.9 4.1 1.2 7.6 1.5 96 15 88 255 9.6 0 9.8 9.6 10/20/2005 16:20:00 6.6 1.5 10.3 2.3 6.6 1.6 9.9 2.3 5.9 1.5 9.9 2.3 102 15 103 255 9.4 0 9.6 9.3 10/20/2005 16:30:00 7.3 1.7 11.8 2.6 7.3 1.7 12.6 3 6 1.6 11.5 1.5 97 18 106 255 9.4 0 9.6 9.3 10/20/2005 16:40:00 7.3 2 12.6 3.4 7.3 1.9 12.6 3.4 6.4 1.8 11.1 2.3 94 16 86 255 9.4 0 9.6 9.3 10/20/2005 16:50:00 6.3 2 11.1 1.9 6.4 1.9 11.5 2.6 5.6 2 10.7 1.1 94 18 114 255 9.2 0 9.3 9 10/20/2005 17:00:00 6.5 1.8 11.5 2.3 6.4 1.7 11.1 1.5 5.6 1.8 10.3 2.3 98 22 95 255 9.1 0 9.3 9 10/20/2005 17:10:00 6.7 1.5 10.7 2.6 6.7 1.5 10.7 2.6 5.7 1.5 8.8 1.9 95 17 100 255 8.9 0 9 9 10/20/2005 17:20:00 7.3 1.7 11.8 3.4 7.4 1.7 12.2 3.4 6.3 1.8 12.6 3 94 13 85 255 8.9 0 9 8.8 10/20/2005 17:30:00 5.8 1.5 10.3 2.6 5.7 1.5 9.5 2.3 4.8 1.5 8.8 1.5 98 19 96 255 8.7 0 9 8.5 10/20/2005 17:40:00 5.9 1.7 9.9 1.9 5.8 1.7 9.5 1.9 4.6 1.6 9.5 1.1 97 17 112 255 8.7 0 8.8 8.5 10/20/2005 17:50:00 5.8 1.4 9.5 2.3 5.7 1.5 9.5 2.6 4.7 1.5 8.8 1.5 84 16 87 255 8.8 0 9 8.8 10/20/2005 18:00:00 5.4 1.3 9.1 2.3 5.4 1.3 8.8 2.3 4.5 1.3 7.6 1.5 80 20 95 255 9 0 9.3 9 10/20/2005 18:10:00 7.3 1.7 11.5 3.8 7.2 1.7 11.5 3.8 6.3 1.4 10.3 3 89 15 79 255 9.4 0.1 9.6 9 10/20/2005 18:20:00 7.5 1.7 13.7 3.8 7.3 1.7 13.3 3.8 6.3 1.7 11.8 2.6 95 17 74 255 9.5 0 9.6 9.3 10/20/2005 18:30:00 5.8 1.5 12.6 2.3 5.7 1.6 12.6 1.9 4.7 1.5 10.3 1.1 95 18 89 255 9.2 0.1 9.6 9 10/20/2005 18:40:00 7.4 1.7 11.5 2.6 7.2 1.7 12.2 2.3 6.4 1.8 11.8 2.3 96 16 98 255 8.7 0 9 8.5 10/20/2005 18:50:00 6.9 1.8 11.5 3.4 6.8 1.8 11.5 3 5.6 1.9 11.1 1.5 96 19 138 255 8.6 0 8.8 8.5 10/20/2005 19:00:00 7 1.9 13.3 3 6.9 1.9 13 2.3 5.8 1.7 10.3 1.9 91 21 97 255 8.5 0 8.8 8.5 10/20/2005 19:10:00 8.4 2.1 14.5 2.6 8.3 2.1 14.1 2.3 7.1 2 14.1 1.9 91 18 97 255 8.4 0 8.5 8.3 10/20/2005 19:20:00 8.4 2.5 14.5 2.6 8.4 2.5 14.9 3 7 2.2 13.3 3 93 18 109 255 8.4 0 8.5 8.5 10/20/2005 19:30:00 8.5 2.3 14.1 2.6 8.4 2.4 13.7 2.6 7 2.2 12.2 2.3 91 17 76 255 8.5 0 8.8 8.5 10/20/2005 19:40:00 8.7 2.3 15.6 3.8 8.8 2.2 16.1 3.8 7.5 2.3 15.3 2.6 90 18 96 255 8.4 0 8.5 8.3 10/20/2005 19:50:00 8.7 2.3 16.1 3.4 8.8 2.2 15.6 3 7.6 2.2 14.1 2.3 96 18 98 255 8.3 0 8.5 8.3 10/20/2005 20:00:00 8.5 2.5 14.9 3.8 8.5 2.5 14.1 3.4 7.2 2.5 14.1 1.1 94 18 104 255 8.3 0 8.5 8.3 10/20/2005 20:10:00 8.8 2.4 15.3 3 8.8 2.4 15.3 3 7.8 2.3 13.3 3 92 17 73 255 8.3 0 8.5 8.3 10/20/2005 20:20:00 9.6 2.3 15.6 4.6 9.6 2.3 16.4 3.4 8.1 2.2 13.3 1.9 92 15 91 255 8.4 0 8.5 8.3 10/20/2005 20:30:00 8.8 2.1 14.9 4.2 8.9 2.1 14.9 4.6 7.4 2.2 13 3 84 18 81 255 8.3 0 8.5 8.3 10/20/2005 20:40:00 8.3 2.1 15.6 3 8.3 2.1 15.3 3.4 6.9 2.2 13.7 1.9 84 17 70 255 8.3 0 8.5 8.3 10/20/2005 20:50:00 8.7 2.5 15.3 3 8.6 2.5 14.5 3.4 7.3 2.1 12.6 3 85 17 94 255 8.3 0 8.5 8.3 10/20/2005 21:00:00 8.7 2.6 14.5 3.8 8.8 2.5 14.5 3.4 7.5 2.4 13 3 90 19 88 255 8.3 0 8.5 8.3 10/20/2005 21:10:00 8.9 2.2 14.1 4.2 8.8 2.1 14.5 4.2 7.5 2.2 13.3 2.6 96 17 99 255 8.2 0 8.5 8 10/20/2005 21:20:00 9.1 2.4 14.9 4.2 9 2.4 14.5 3.8 8 2.4 13.7 2.3 92 17 95 255 8.1 0 8.3 8 10/20/2005 21:30:00 8.2 2.2 13 2.6 8.2 2.2 13 3.4 7 2 12.6 2.6 84 17 88 255 8.1 0 8.3 8 10/20/2005 21:40:00 7.6 1.8 12.2 3.4 7.5 1.8 11.8 3 6.4 1.7 10.7 2.6 83 17 82 255 8 0 8.3 8 10/20/2005 21:50:00 6 1.3 9.9 2.6 5.9 1.3 9.9 2.6 5.1 1.3 8.4 2.3 77 16 84 255 8 0 8.3 7.8 10/20/2005 22:00:00 4.5 1.4 8 1.9 4.4 1.4 8.4 1.5 3.9 1.3 7.6 1.1 66 24 80 255 7.9 0 8 7.8 10/20/2005 22:10:00 1.7 0.6 3.4 0.4 1.4 0.7 3 0.4 1.4 0.7 3.4 0.4 47 18 23 255 7.1 0.3 7.8 6.7 10/20/2005 22:20:00 4.3 2.3 10.7 0.7 4.2 2.4 10.3 0.4 3.5 1.9 8.4 0.4 108 23 82 255 6.9 0.4 7.8 6.2 10/20/2005 22:30:00 7 1.9 12.6 3 7 1.9 13 2.6 6.1 1.8 11.8 1.9 102 15 90 255 8.3 0.1 8.5 7.8 10/20/2005 22:40:00 5.3 1.9 10.7 1.1 5.3 2 10.7 0.7 4.5 1.8 9.5 1.1 89 26 94 255 8.3 0 8.5 8.3 10/20/2005 22:50:00 9.2 2 14.1 4.2 9.1 2.1 13.3 4.6 7.7 1.8 13 3 96 16 106 255 8.5 0 8.8 8.5 10/20/2005 23:00:00 7.7 2 12.6 2.6 7.6 2 13 2.6 6.4 2.1 11.5 1.5 94 20 68 255 8.5 0 8.5 8.5 10/20/2005 23:10:00 7.4 1.7 12.6 4.2 7.3 1.7 12.6 3.8 6.3 1.5 11.5 2.6 80 18 81 255 8.6 0 8.8 8.5 10/20/2005 23:20:00 5.1 0.9 7.6 3 4.9 0.9 7.2 2.6 4.6 1 7.2 2.3 54 11 72 255 7.5 0.6 8.5 6.5 10/20/2005 23:30:00 2.7 0.8 4.6 0.7 2.5 0.9 4.6 0.4 2.2 0.7 3.8 0.4 61 17 67 255 5.9 0.3 6.5 5.5 10/20/2005 23:40:00 2.7 0.5 3.8 1.5 2.8 0.5 4.2 1.5 2.1 0.5 3.4 0.7 49 16 55 255 5.1 0.1 5.5 4.8 10/20/2005 23:50:00 1.9 0.6 4.2 0.7 1.8 0.7 3.8 0.4 1.3 0.6 2.6 0.4 17 29 58 255 4.6 0 4.8 4.5 10/21/2005 00:00:00 1 0.7 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.6 2.6 0.4 340 20 336 255 4.1 0.1 4.8 3.8 10/21/2005 00:10:00 1.8 1.1 3.8 0.4 1.7 1.1 3.8 0.4 1.4 1 3.4 0.4 332 66 320 255 3.6 0 3.8 3.5 10/21/2005 00:20:00 1.5 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.3 0.6 2.6 0.4 299 24 291 255 3.5 0 3.5 3.3 10/21/2005 00:30:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 276 16 288 255 3.3 0 3.8 3.3 10/21/2005 00:40:00 1 0.6 3.4 0.4 0.7 0.6 2.6 0.4 0.8 0.5 2.3 0.4 246 79 322 255 3 0.1 3.8 2.8 10/21/2005 00:50:00 2.9 1 4.6 0.7 2.6 1.1 4.2 0.4 2.2 1 3.8 0.4 259 10 265 255 3.1 0.2 3.5 2.8 10/21/2005 01:00:00 1.7 0.7 3.8 0.4 1.4 0.8 3.4 0.4 1.3 0.8 3.8 0.4 236 86 88 255 3.7 0.1 4.3 3.5 10/21/2005 01:10:00 0.9 0.7 3 0.4 0.7 0.6 3 0.4 0.6 0.5 2.6 0.4 311 64 250 255 4 0 4.3 4 10/21/2005 01:20:00 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 274 41 227 255 3.8 0.1 4 3.5 10/21/2005 01:30:00 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 339 27 317 255 3.5 0 3.5 3.5 10/21/2005 01:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 66 107 32 255 3.4 0 3.5 3.3 10/21/2005 01:50:00 1.1 0.8 2.6 0.4 0.9 0.7 2.6 0.4 0.9 0.6 2.3 0.4 23 3 25 255 3.2 0 3.5 3 10/21/2005 02:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 22 0 22 255 3 0 3.3 2.8 10/21/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 255 255 2.7 0 3 2.6 10/21/2005 02:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 27 22 22 255 2.6 0 2.8 2.3 10/21/2005 02:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 95 47 44 255 2.3 0 2.6 2.3 10/21/2005 02:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 62 22 45 255 2.3 0 2.6 2.3 10/21/2005 02:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 90 10 106 255 2.3 0 2.6 2.3 10/21/2005 03:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 118 5 119 255 2.1 0 2.3 1.8 10/21/2005 03:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 119 0 119 255 1.9 0 2.1 1.8 10/21/2005 03:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 35 45 335 255 1.8 0 2.1 1.8 10/21/2005 03:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 359 0 0 255 1.8 0 2.3 1.8 10/21/2005 03:40:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 356 7 359 255 1.7 0 1.8 1.6 10/21/2005 03:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 34 14 38 255 1.6 0 1.8 1.4 10/21/2005 04:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 67 35 105 255 1.5 0 1.6 1.4 10/21/2005 04:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 137 17 158 255 1.4 0 1.6 1.4 10/21/2005 04:20:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 115 11 122 255 1.5 0 1.6 1.6 10/21/2005 04:30:00 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.3 0.4 88 19 88 255 1.7 0 1.8 1.6 10/21/2005 04:40:00 1.5 1.2 5.3 0.4 1.3 1.2 5.7 0.4 1 0.7 4.9 0.4 45 35 73 255 1.8 0 1.8 1.6 10/21/2005 04:50:00 1.6 0.5 3.4 0.4 1.4 0.5 3.4 0.4 0.7 0.4 1.9 0.4 82 14 80 255 1.7 0 1.8 1.6 10/21/2005 05:00:00 2.4 0.6 3.8 1.1 2.3 0.7 3.8 1.1 1.8 0.5 3 0.4 54 9 51 255 1.8 0 2.1 1.6 10/21/2005 05:10:00 2.7 0.7 4.6 1.5 2.5 0.7 4.6 1.1 1.6 0.6 3.4 0.4 63 14 66 255 1.8 0 2.1 1.8 10/21/2005 05:20:00 3.3 1.1 6.1 0.4 3.1 1.1 6.1 0.7 2.4 0.8 5.3 0.7 79 18 75 255 2.1 0.2 2.8 1.8 10/21/2005 05:30:00 2.5 0.9 4.9 0.4 2.4 0.9 5.3 0.4 1.8 0.8 4.2 0.4 52 21 45 255 2.7 0 2.8 2.6 10/21/2005 05:40:00 3.1 0.7 4.9 1.9 3 0.7 4.9 1.5 2.2 0.7 3.8 0.4 61 22 54 255 2.7 0 2.8 2.6 10/21/2005 05:50:00 3.8 1.3 7.2 1.5 3.6 1.3 7.6 1.1 2.6 1.2 6.5 0.4 90 17 101 255 3.2 0.4 4.5 2.8 10/21/2005 06:00:00 5.8 1.2 9.1 3 5.7 1.3 8.8 1.9 4.8 1.2 7.6 1.9 97 15 109 255 6.1 0.7 7 4.5 10/21/2005 06:10:00 6.2 1.6 10.3 2.3 6.3 1.6 10.3 1.5 5.3 1.5 9.9 1.1 95 15 102 255 7.3 0 7.5 7 10/21/2005 06:20:00 5.7 1.5 9.9 2.6 5.8 1.5 9.9 2.6 4.8 1.4 8.8 1.9 95 16 92 255 7.3 0 7.5 7.3 10/21/2005 06:30:00 5 1.6 10.3 1.9 5.1 1.6 10.3 1.5 4 1.5 8 1.1 84 17 106 255 7.3 0 7.3 7.3 10/21/2005 06:40:00 4.6 1 8 1.9 4.6 1.1 8 1.5 3.9 1.1 6.8 1.1 81 18 94 255 7.1 0 7.3 7 10/21/2005 06:50:00 3.5 1 6.1 0.7 3.4 1.1 5.7 0.7 3 0.9 5.7 1.1 72 21 73 255 7 0 7.3 7 10/21/2005 07:00:00 3.9 1.1 7.2 1.9 3.8 1.2 8 1.5 3.3 1.1 6.8 1.1 63 22 77 255 6.4 0.2 7 6.2 10/21/2005 07:10:00 5.1 1.5 9.1 1.9 5 1.6 9.5 1.5 4 1.5 9.1 1.1 84 21 93 255 6.5 0.2 7 6.2 10/21/2005 07:20:00 5.1 1.1 8 2.6 5 1.2 8 2.3 4.2 1.1 7.6 1.9 87 17 92 255 6.9 0 7 6.7 10/21/2005 07:30:00 5.5 1.2 8.4 2.3 5.3 1.3 8.4 2.3 4.6 1.2 8.4 1.9 89 13 112 255 6.7 0 7 6.7 10/21/2005 07:40:00 5.3 0.9 7.6 2.6 5.2 1 7.6 2.6 4.4 1.2 7.6 1.1 82 12 90 255 6.7 0 6.7 6.7 10/21/2005 07:50:00 4.5 0.8 6.8 2.6 4.3 0.8 6.8 2.3 3.8 0.9 6.1 1.9 80 12 82 255 6.6 0 6.7 6.5 10/21/2005 08:00:00 4.9 1.2 8 1.9 4.8 1.3 7.6 1.5 4 1.2 6.5 1.5 101 17 115 255 6.6 0 6.7 6.2 10/21/2005 08:10:00 5 1.2 8.4 2.3 4.8 1.3 8.8 1.1 4.2 1.1 6.8 1.5 104 17 110 255 6.8 0 7 6.7 10/21/2005 08:20:00 5.6 1.3 8.8 2.3 5.5 1.3 8.8 2.6 4.8 1.3 8 2.3 103 16 111 255 7.1 0 7.3 7 10/21/2005 08:30:00 6.8 1.4 10.3 3 6.7 1.5 10.3 3 5.6 1.4 9.5 2.6 103 16 84 255 7.3 0 7.3 7.3 10/21/2005 08:40:00 6.8 1.8 11.8 3 6.7 1.8 11.5 2.6 5.6 1.7 9.5 1.5 98 17 95 255 7.3 0 7.5 7.3 10/21/2005 08:50:00 6.5 1.7 10.7 2.3 6.4 1.7 10.3 1.9 5.5 1.5 10.7 1.5 102 17 100 255 7.4 0 7.5 7.3 10/21/2005 09:00:00 6.7 1.7 12.2 3 6.7 1.7 11.5 3.8 5.9 1.6 10.7 1.9 100 15 105 255 7.5 0 7.5 7.5 10/21/2005 09:10:00 7.2 1.6 10.7 2.6 7.1 1.6 10.7 3.4 5.9 1.6 11.1 1.5 96 17 105 255 7.3 0 7.5 7.3 10/21/2005 09:20:00 6.2 1.4 10.3 3 6.2 1.4 10.3 3 5.2 1.4 8.8 1.5 94 15 94 255 7.3 0 7.3 7.3 10/21/2005 09:30:00 4.6 1 7.2 1.5 4.4 1 6.8 1.5 3.8 0.9 6.5 1.1 81 15 66 255 7.3 0 7.3 7.3 10/21/2005 09:40:00 4.5 1.1 8.4 1.9 4.4 1.1 7.6 1.5 3.6 1 6.1 1.1 81 17 88 255 7.3 0 7.3 7.3 10/21/2005 09:50:00 4.8 1.2 8.4 2.3 4.6 1.3 8 1.5 3.9 1.2 7.6 1.5 87 17 93 255 7.4 0 7.8 7.3 10/21/2005 10:00:00 3.6 1 6.8 0.4 3.3 1.1 6.5 0.4 3.1 0.9 5.3 0.4 84 28 68 255 7.8 0 8 7.5 10/21/2005 10:10:00 5.4 1.4 8.8 1.9 5.3 1.5 8.8 1.5 4.4 1.5 8.4 1.5 88 15 106 255 8 0 8.3 8 10/21/2005 10:20:00 5.4 1.3 9.1 2.6 5.2 1.3 9.1 2.3 4.4 1.4 8 0.7 83 15 81 255 8.1 0 8.3 8 10/21/2005 10:30:00 4.8 0.9 7.6 2.3 4.6 1 7.6 1.5 3.9 0.8 6.1 1.9 70 17 96 255 8 0 8.3 7.8 10/21/2005 10:40:00 4.3 1 6.5 1.9 4.1 1 6.5 1.5 3.7 1 6.1 1.1 66 15 61 255 7.9 0 8 7.8 10/21/2005 10:50:00 4.8 1 7.6 1.9 4.6 1.1 7.6 1.1 3.9 1.1 7.2 1.5 66 19 77 255 8 0 8.3 7.8 10/21/2005 11:00:00 4 1.3 8.4 1.9 3.7 1.4 9.1 1.1 3.3 1.3 7.6 1.1 69 21 84 255 7.8 0 8 7.8 10/21/2005 11:10:00 3.9 1 6.5 1.5 3.7 1 6.5 1.1 3.3 1.1 6.5 1.1 64 23 97 255 8 0 8.3 7.8 10/21/2005 11:20:00 5.2 0.9 8 3 5 1 8 2.6 4.6 1 7.6 2.3 66 12 70 255 8.2 0 8.5 8 10/21/2005 11:30:00 4.5 1 7.6 2.3 4.3 1.1 7.6 1.9 3.7 1 6.1 1.1 51 15 71 255 8.5 0 8.8 8.5 10/21/2005 11:40:00 6.4 1.3 10.7 3.4 6.3 1.4 10.7 3 5.7 1.2 9.1 2.6 62 15 32 255 8.2 0.1 8.5 8 10/21/2005 11:50:00 8.2 1.3 10.7 4.6 8.1 1.4 11.1 4.2 6.9 1.4 10.3 3.4 42 12 36 255 8 0 8.3 7.8 10/21/2005 12:00:00 7 1.7 10.7 2.6 6.9 1.7 10.7 2.6 6 1.5 8.8 1.9 48 14 47 255 7.6 0 8 7.5 10/21/2005 12:10:00 8.2 1.3 12.2 4.2 8.1 1.4 12.2 4.2 7.1 1.5 11.5 3.4 41 13 53 255 7.7 0 7.8 7.5 10/21/2005 12:20:00 5.6 1.3 9.9 1.9 5.6 1.3 10.3 2.3 4.9 1.2 8 2.3 51 17 56 255 7.8 0 8 7.8 10/21/2005 12:30:00 5 1.2 8 1.9 4.9 1.2 8 1.1 4.3 1.2 7.2 0.7 56 18 42 255 8 0 8 7.8 10/21/2005 12:40:00 5.1 1.3 8.8 2.6 4.9 1.5 8.4 2.3 4.4 1.3 8.4 1.9 64 17 63 255 8 0 8 7.8 10/21/2005 12:50:00 4.2 0.9 8 2.3 4.1 1 7.6 1.9 3.5 1 6.8 1.1 73 17 91 255 8.1 0 8.3 8 10/21/2005 13:00:00 5 1.4 8 2.3 4.8 1.5 8 1.1 4.4 1.4 7.6 1.1 76 15 98 255 8.1 0 8.3 8 10/21/2005 13:10:00 4.5 1.1 7.6 2.3 4.2 1.1 7.6 1.9 3.9 1.2 6.8 1.5 84 19 106 255 8.1 0 8.3 8 10/21/2005 13:20:00 5.6 1.3 8.8 2.3 5.4 1.3 8.8 2.6 4.8 1.4 8 1.1 90 18 83 255 7.8 0 8.3 7.5 10/21/2005 13:30:00 5.4 1.3 8.8 2.6 5.2 1.3 9.5 2.3 4.4 1.2 8.4 1.9 92 17 106 255 7.6 0 7.8 7.5 10/21/2005 13:40:00 6.2 1.2 9.5 2.6 6.1 1.2 9.5 2.6 5.2 1.1 8.8 2.3 98 16 104 255 7.6 0 7.8 7.5 10/21/2005 13:50:00 7 1.3 10.7 3.4 6.9 1.3 10.3 3.4 5.8 1.3 9.1 2.6 83 16 76 255 7.6 0 7.8 7.5 10/21/2005 14:00:00 6.3 1.3 9.5 3 6.1 1.3 10.3 3.4 5.3 1.3 9.9 2.3 74 16 88 255 7.7 0 7.8 7.5 10/21/2005 14:10:00 6.8 1.7 11.5 2.3 6.8 1.7 11.1 2.6 5.9 1.7 9.9 2.6 66 19 56 255 7.8 0 7.8 7.5 10/21/2005 14:20:00 6.8 1.5 11.5 3.4 6.7 1.6 11.5 2.6 6 1.5 10.3 2.6 53 17 37 255 7.9 0 8 7.8 10/21/2005 14:30:00 7.5 1.4 11.1 3 7.5 1.4 11.1 3.8 6.6 1.5 10.7 3.4 46 16 26 255 8 0 8 7.8 10/21/2005 14:40:00 6.4 2 11.1 2.3 6.3 2 11.5 2.3 5.6 1.7 10.3 2.3 46 16 42 255 7.9 0 8 7.8 10/21/2005 14:50:00 6.1 1.3 10.3 3 6 1.3 9.9 3 5.2 1.3 9.1 2.3 57 17 62 255 7.8 0 8 7.8 10/21/2005 15:00:00 5.8 1.4 9.1 3 5.7 1.4 9.1 3 4.9 1.5 9.5 2.3 72 17 56 255 7.8 0 7.8 7.8 10/21/2005 15:10:00 5.7 1.7 10.7 2.3 5.5 1.7 10.3 1.9 4.8 1.7 9.9 1.5 73 18 56 255 7.8 0 7.8 7.8 10/21/2005 15:20:00 5.9 1.4 9.9 2.3 5.8 1.4 10.3 1.9 5 1.4 9.9 2.3 74 16 71 255 7.9 0 8 7.8 10/21/2005 15:30:00 6.1 1.4 10.3 3.4 5.9 1.5 10.3 3 5.4 1.4 9.5 2.3 70 17 60 255 8 0 8.3 7.8 10/21/2005 15:40:00 5.5 1.2 10.7 2.6 5.4 1.3 9.9 2.6 4.5 1.1 8 1.5 83 13 76 255 8.1 0 8.3 8 10/21/2005 15:50:00 5.6 1 8.8 3 5.5 1 8.4 2.6 4.7 1.2 7.6 1.9 68 18 102 255 8.2 0 8.5 8.3 10/21/2005 16:00:00 5.9 1.2 9.5 3 5.7 1.2 9.1 3 5.1 1.1 8.4 1.9 70 24 52 255 8.3 0 8.5 8.3 10/21/2005 16:10:00 5.8 1.7 9.9 2.6 5.7 1.7 9.9 2.3 4.9 1.6 9.5 1.9 78 19 77 255 8.3 0 8.5 8.3 10/21/2005 16:20:00 5.1 0.9 7.2 2.6 4.9 0.9 7.2 2.6 4.2 1 6.8 1.9 86 15 108 255 8.1 0 8.3 8 10/21/2005 16:30:00 4.7 1.5 8.8 1.9 4.5 1.5 8.8 1.5 3.8 1.3 7.6 0.7 90 16 115 255 8 0 8.3 7.8 10/21/2005 16:40:00 6 1.5 9.9 2.3 5.9 1.5 9.9 2.6 5.1 1.3 9.1 1.9 95 16 103 255 8 0 8 7.8 10/21/2005 16:50:00 6.2 1.3 11.1 3 6 1.3 10.7 2.3 5.3 1.1 9.1 2.6 104 15 117 255 7.8 0 8 7.8 10/21/2005 17:00:00 5 1.2 8 1.5 4.8 1.2 8 1.9 4 1.2 7.6 0.7 106 16 119 255 7.6 0.1 7.8 7.5 10/21/2005 17:10:00 5.7 1.3 8.8 2.3 5.5 1.3 9.1 2.3 4.9 1.4 8.8 1.1 111 16 116 255 7.7 0 7.8 7.5 10/21/2005 17:20:00 5.8 1.3 9.5 3 5.7 1.4 9.5 2.6 4.9 1.3 9.1 2.3 96 16 93 255 7.9 0 8 7.8 10/21/2005 17:30:00 5.8 1.3 8.8 2.6 5.7 1.3 8.8 2.3 4.7 1.3 8.4 2.3 75 14 83 255 7.7 0 7.8 7.5 10/21/2005 17:40:00 6.5 1.1 8.8 3 6.4 1.1 8.8 3.8 5.5 1.1 8 2.6 84 12 88 255 7.6 0 7.8 7.5 10/21/2005 17:50:00 6.1 1.3 9.5 3.4 6 1.3 9.5 3 5.2 1.3 8 2.6 94 15 74 255 7.5 0 7.8 7.5 10/21/2005 18:00:00 5.9 1.2 9.1 3 5.8 1.2 8.4 2.6 4.8 1.2 7.6 1.5 91 16 101 255 7.5 0 7.5 7.3 10/21/2005 18:10:00 4.8 1.1 7.6 2.3 4.7 1.1 7.6 1.9 4.1 1.2 6.8 1.1 87 21 100 255 7.4 0 7.5 7.3 10/21/2005 18:20:00 5.6 1.3 9.9 2.6 5.4 1.3 9.5 2.3 4.7 1.4 8.8 1.9 61 19 57 255 7.4 0 7.5 7.3 10/21/2005 18:30:00 5.4 1.3 8.8 2.6 5.2 1.4 8.8 2.6 4.5 1.3 8.4 0.7 78 21 70 255 7.5 0.1 7.8 7.3 10/21/2005 18:40:00 5.1 1.1 8 2.3 4.9 1.1 8 1.5 4.3 1.2 7.2 1.5 90 16 95 255 7.3 0 7.5 7.3 10/21/2005 18:50:00 5.8 1.1 8.8 1.9 5.7 1.1 9.1 1.9 4.9 1.2 7.2 2.3 95 15 101 255 7.4 0 7.5 7.3 10/21/2005 19:00:00 5.2 1.5 10.7 2.3 5.1 1.5 11.8 2.3 4.5 1.5 9.1 1.1 84 22 88 255 7.4 0.1 7.8 7.3 10/21/2005 19:10:00 5.3 1.3 8.4 2.3 5.2 1.3 8.4 2.3 4.5 1.3 8.4 1.5 64 16 43 255 7.4 0 7.5 7.5 10/21/2005 19:20:00 5.8 1.8 11.1 2.6 5.7 1.9 11.1 2.3 5 1.7 10.3 2.3 43 17 43 255 7.4 0 7.5 7.3 10/21/2005 19:30:00 7.2 2.3 13.7 2.6 7.1 2.4 14.1 2.3 6.2 2.2 12.6 2.3 46 17 58 255 7.5 0 7.8 7.3 10/21/2005 19:40:00 9.3 1.7 13.3 5.3 9.2 1.7 13.7 5.3 7.9 1.8 12.2 3.8 30 13 16 255 7.3 0 7.5 7.3 10/21/2005 19:50:00 8.6 1.9 13.7 4.2 8.6 1.9 13.7 3.8 7.5 1.9 12.2 3.8 33 15 22 255 7.1 0 7.3 7 10/21/2005 20:00:00 7.9 1.5 11.1 3.8 7.8 1.5 11.5 3.8 6.7 1.5 10.7 2.6 48 17 53 255 6.8 0 7.3 6.7 10/21/2005 20:10:00 5.2 1.5 9.1 1.9 5.1 1.5 9.5 1.9 4.5 1.3 9.1 1.1 68 18 42 255 6.6 0.1 6.7 6.2 10/21/2005 20:20:00 6.4 1.9 11.5 1.5 6.3 2 11.1 1.5 5.4 1.9 9.5 1.1 49 21 7 255 6.3 0 6.5 6.2 10/21/2005 20:30:00 9.3 1.7 14.5 5.7 9.3 1.8 14.5 5.7 7.9 1.7 13 3.8 26 13 30 255 6.2 0 6.5 6.2 10/21/2005 20:40:00 9.7 1.5 14.5 6.1 9.6 1.5 14.9 4.9 8.4 1.7 13.7 4.2 32 15 46 255 6.2 0 6.2 6 10/21/2005 20:50:00 7.9 1.8 11.8 3.4 7.8 1.8 12.2 3.8 6.9 1.9 11.8 2.3 39 15 40 255 5.9 0 6 5.7 10/21/2005 21:00:00 7.9 2 14.5 3.4 7.9 2 14.1 3 6.6 2 12.6 2.3 50 17 16 255 5.8 0 6 5.7 10/21/2005 21:10:00 6.4 1.4 11.8 3 6.3 1.4 11.5 2.6 5.5 1.2 9.1 3 72 18 37 255 5.7 0 6 5.7 10/21/2005 21:20:00 7.1 1.5 11.8 3 7 1.5 11.5 3.8 6 1.5 10.7 2.6 62 18 43 255 5.6 0 5.7 5.7 10/21/2005 21:30:00 6.7 1.5 10.7 3.8 6.6 1.5 10.3 3.4 5.8 1.5 10.3 2.6 55 17 30 255 5.6 0 5.7 5.7 10/21/2005 21:40:00 4.7 1.3 8.8 2.3 4.6 1.5 9.5 1.5 4.2 1.5 8 1.1 82 20 53 255 5.5 0 5.7 5.2 10/21/2005 21:50:00 7 1.7 11.5 2.6 7 1.8 11.5 2.6 6 1.7 10.7 1.9 56 17 56 255 5.4 0 5.5 5.2 10/21/2005 22:00:00 8.6 1.7 12.2 3.8 8.6 1.7 12.2 3.8 7.3 1.7 11.8 3.8 49 13 54 255 5.4 0 5.5 5.2 10/21/2005 22:10:00 9.9 1.4 13.3 4.6 9.9 1.5 13.3 4.9 8.6 1.7 12.2 4.6 40 11 37 255 5.4 0 5.5 5.2 10/21/2005 22:20:00 7 1.6 10.7 3 6.9 1.7 11.5 3 6 1.5 10.3 2.6 50 13 42 255 5.4 0 5.5 5.2 10/21/2005 22:30:00 7.5 1.4 11.8 4.2 7.5 1.5 11.8 3.4 6.5 1.4 11.1 3.8 40 13 38 255 5.4 0 5.7 5.2 10/21/2005 22:40:00 8.7 1.5 13 4.2 8.7 1.5 13.3 4.6 7.5 1.7 13.7 3.8 42 13 48 255 5.7 0 5.7 5.5 10/21/2005 22:50:00 8.1 1.8 13 3.8 8.1 1.9 13.3 4.2 7 1.6 11.5 3 54 15 55 255 5.7 0 6 5.7 10/21/2005 23:00:00 9.8 1.5 13.7 6.5 9.8 1.5 13.7 6.1 8.4 1.7 13 3.8 48 11 48 255 5.7 0 6 5.7 10/21/2005 23:10:00 6.9 1.9 11.8 3 6.8 1.9 11.8 3 5.9 1.7 11.1 2.6 58 16 53 255 5.6 0 5.7 5.7 10/21/2005 23:20:00 6.8 1.7 11.1 3 6.7 1.9 11.5 2.6 5.8 1.7 10.7 3 63 17 49 255 5.6 0 5.7 5.7 10/21/2005 23:30:00 6.4 1.5 9.9 3.4 6.4 1.6 10.3 3.4 5.4 1.3 10.3 2.3 63 17 52 255 5.7 0 6 5.7 10/21/2005 23:40:00 6.2 1.1 9.1 2.3 6 1.2 9.1 2.6 5 1.2 8 2.6 63 15 60 255 5.8 0 6 5.7 10/21/2005 23:50:00 5.5 1 8.4 3 5.4 1 8 3 4.6 1 7.2 2.3 67 16 62 255 5.7 0 6 5.7 10/22/2005 00:00:00 5.5 1.2 9.5 2.3 5.4 1.2 9.1 2.3 4.8 1.2 8.4 2.6 64 17 81 255 5.8 0 6 5.7 10/22/2005 00:10:00 4.8 1.1 8.4 2.3 4.7 1.2 8 2.3 4 1.1 7.2 1.5 78 17 86 255 5.8 0 6 5.5 10/22/2005 00:20:00 5 1 7.6 2.6 4.8 1.1 7.6 2.3 4 1 6.5 1.5 83 15 69 255 5.4 0 5.7 5.2 10/22/2005 00:30:00 5.4 1.2 8 2.3 5.3 1.2 8 1.9 4.5 1.1 6.8 1.5 83 13 98 255 5.1 0 5.5 5 10/22/2005 00:40:00 5.6 1 8.4 3.4 5.5 1 8.4 3 4.6 1.1 7.2 1.9 84 13 83 255 5 0 5 4.8 10/22/2005 00:50:00 5.5 1.1 8.4 3 5.5 1.1 8.4 3 4.6 1.2 7.2 1.5 82 14 77 255 5.1 0.1 5.2 5 10/22/2005 01:00:00 5.5 1.2 9.1 3 5.4 1.2 9.5 2.6 4.5 1.1 8 2.3 82 14 100 255 5.2 0 5.2 5 10/22/2005 01:10:00 3.9 0.9 6.1 1.5 3.7 1 6.1 1.5 3.2 0.9 5.7 1.1 95 13 105 255 5.1 0 5.2 4.8 10/22/2005 01:20:00 4 0.8 6.1 1.9 3.8 0.8 5.7 1.1 3.2 0.8 4.9 1.1 95 12 91 255 4.6 0 5 4.5 10/22/2005 01:30:00 4.1 0.8 6.5 2.3 4 0.8 5.7 1.9 3.1 0.8 5.3 1.1 99 14 94 255 4.5 0 4.5 4.5 10/22/2005 01:40:00 4.3 0.7 6.1 2.6 4.1 0.7 5.7 2.3 3.2 0.8 4.9 1.5 97 12 88 255 4.6 0 4.8 4.5 10/22/2005 01:50:00 4.3 0.8 6.5 1.9 4.1 0.8 6.1 1.9 3.3 0.8 5.7 1.1 101 11 94 255 4.7 0 4.8 4.5 10/22/2005 02:00:00 4.1 0.8 6.1 2.3 3.9 0.7 6.1 1.9 2.9 0.7 5.3 1.1 112 12 116 255 4.5 0 4.5 4.5 10/22/2005 02:10:00 4.5 0.8 6.5 2.3 4.3 0.8 6.5 2.3 3.3 0.9 5.7 1.1 107 13 100 255 4.6 0.1 4.8 4.5 10/22/2005 02:20:00 3.4 0.7 5.3 1.9 3.2 0.7 4.9 1.5 2.5 0.7 4.6 0.4 95 14 98 255 4.8 0 5 4.8 10/22/2005 02:30:00 3.5 0.6 5.7 1.9 3.2 0.6 5.3 1.5 2.6 0.6 4.2 1.1 86 13 91 255 4.6 0 4.8 4.5 10/22/2005 02:40:00 3.7 0.7 5.3 1.9 3.5 0.8 5.3 1.5 2.9 0.8 4.9 1.1 70 13 75 255 4.9 0.1 5.2 4.8 10/22/2005 02:50:00 3.1 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2.3 0.5 3.8 1.1 74 11 64 255 5.2 0 5.5 5 10/22/2005 03:00:00 3.5 0.7 5.3 1.5 3.3 0.7 4.9 1.1 2.8 0.7 4.6 0.4 89 11 69 255 5.2 0 5.5 5 10/22/2005 03:10:00 3.8 0.7 5.7 1.9 3.6 0.8 5.7 1.5 2.9 0.7 4.6 1.1 75 18 78 255 5.5 0 5.7 5.2 10/22/2005 03:20:00 3.5 0.5 4.9 2.6 3.3 0.5 4.9 2.3 2.8 0.6 4.2 0.7 66 12 96 255 5.8 0 6 5.7 10/22/2005 03:30:00 3.4 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.6 0.7 4.2 1.1 74 13 90 255 6 0 6.2 6 10/22/2005 03:40:00 2.9 0.6 4.9 1.5 2.6 0.6 4.9 1.1 2.2 0.6 4.2 0.4 57 13 79 255 6.1 0 6.2 6 10/22/2005 03:50:00 2.6 0.4 3.8 1.9 2.3 0.4 3.8 1.5 2 0.4 3 0.7 45 18 63 255 5.9 0 6.2 5.7 10/22/2005 04:00:00 1.6 0.5 3 0.4 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 56 22 83 255 5.6 0 5.7 5.5 10/22/2005 04:10:00 1.9 0.8 3.8 0.4 1.4 0.8 3.4 0.4 0.9 0.6 2.6 0.4 95 35 64 255 5.3 0 5.5 5 10/22/2005 04:20:00 2.2 1 5.3 0.4 1.8 1 4.9 0.4 1.4 0.8 4.2 0.4 60 26 102 255 5.1 0 5.2 5 10/22/2005 04:30:00 4.1 1 6.8 1.9 3.8 1 6.8 1.5 3.5 1 6.5 1.1 76 15 80 255 5.6 0.3 6.2 5 10/22/2005 04:40:00 3.3 0.8 5.3 1.5 3.1 0.9 4.9 0.7 2.5 0.7 4.6 0.7 71 17 71 255 6.2 0 6.2 6 10/22/2005 04:50:00 3.7 0.5 4.9 2.3 3.4 0.5 4.9 1.9 2.8 0.6 4.6 1.1 48 12 45 255 6 0.1 6.2 5.7 10/22/2005 05:00:00 3.6 0.7 5.3 1.5 3.4 0.8 4.9 0.7 2.8 0.7 4.6 0.7 61 14 51 255 5.7 0 6 5.7 10/22/2005 05:10:00 3.1 0.7 4.9 1.1 2.8 0.7 4.6 0.7 2.3 0.6 4.2 0.7 71 13 78 255 5.9 0 6 5.7 10/22/2005 05:20:00 2.9 0.5 4.2 1.1 2.6 0.6 3.8 0.7 2 0.6 3.4 0.7 72 13 67 255 6 0 6 6 10/22/2005 05:30:00 2.9 0.6 4.6 1.1 2.6 0.7 4.2 0.4 2.2 0.6 3.8 0.7 67 11 61 255 6.1 0 6.2 6 10/22/2005 05:40:00 2.9 0.7 4.6 1.1 2.6 0.7 4.6 0.7 2.1 0.7 4.2 0.7 74 17 92 255 6.1 0 6.2 6 10/22/2005 05:50:00 3.1 0.6 4.9 1.5 2.9 0.7 4.9 1.1 2.3 0.6 3.8 0.7 80 16 86 255 5.8 0.1 6 5.7 10/22/2005 06:00:00 5 1.3 8.4 2.6 4.7 1.3 8 2.3 4.2 1.4 8 1.9 91 15 101 255 5.7 0 5.7 5.7 10/22/2005 06:10:00 6.3 1.5 10.7 3.4 6.3 1.5 10.3 3 5.3 1.5 9.1 1.9 90 16 88 255 5.7 0 6 5.7 10/22/2005 06:20:00 6.7 2 12.2 3 6.6 2 12.2 2.6 5.5 1.9 11.1 1.1 86 18 105 255 5.7 0 6 5.7 10/22/2005 06:30:00 4.9 1.3 9.1 2.3 4.7 1.3 8.4 1.9 4.2 1.3 8 1.9 75 21 78 255 5.8 0 6 5.7 10/22/2005 06:40:00 3.5 0.7 4.9 1.5 3.2 0.8 4.6 0.7 2.7 0.8 4.2 1.1 63 13 55 255 5.7 0 5.7 5.7 10/22/2005 06:50:00 3.5 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.8 0.6 4.6 1.5 71 14 75 255 5.6 0 5.7 5.5 10/22/2005 07:00:00 3.8 0.5 5.3 2.6 3.6 0.6 4.9 2.3 3 0.6 4.6 1.5 71 14 73 255 5.4 0 5.5 5.2 10/22/2005 07:10:00 3.8 0.8 5.7 1.9 3.5 0.9 5.7 1.5 3.1 0.8 4.9 1.5 62 17 62 255 5.3 0 5.5 5.2 10/22/2005 07:20:00 3.5 0.8 5.7 1.9 3.3 0.8 5.3 1.1 2.7 0.8 4.6 1.1 66 14 70 255 5.1 0 5.5 5 10/22/2005 07:30:00 3 0.9 5.3 1.5 2.8 0.9 4.6 0.7 2.3 0.8 4.2 0.7 65 16 52 255 4.9 0 5 4.8 10/22/2005 07:40:00 4.1 0.6 5.3 2.3 3.9 0.6 5.3 1.9 3.4 0.7 4.9 1.5 52 10 48 255 4.7 0 5 4.5 10/22/2005 07:50:00 4.3 0.5 6.1 2.6 4.1 0.6 5.3 2.3 3.6 0.7 4.9 1.9 44 9 37 255 4.4 0 4.8 4.3 10/22/2005 08:00:00 4.6 0.8 6.5 2.3 4.4 0.8 6.1 1.9 3.8 0.9 5.7 1.1 38 11 36 255 4.1 0 4.3 4 10/22/2005 08:10:00 4.3 0.9 6.5 2.3 4.2 1 6.5 1.9 3.5 1 6.1 1.1 54 14 53 255 4 0 4 4 10/22/2005 08:20:00 4.7 0.6 6.1 3.4 4.5 0.6 6.1 3 4 0.7 5.7 1.5 43 10 43 255 4 0 4 3.8 10/22/2005 08:30:00 3.8 0.9 5.7 1.1 3.7 1 5.3 1.1 3.2 1 4.9 0.7 43 15 49 255 3.8 0 4 3.8 10/22/2005 08:40:00 3.7 0.6 5.3 2.3 3.5 0.7 5.3 1.9 3 0.7 4.6 1.1 42 11 52 255 3.8 0 3.8 3.8 10/22/2005 08:50:00 4.6 0.8 6.5 2.3 4.4 0.8 6.5 1.9 3.7 0.8 5.7 1.5 43 11 45 255 3.9 0 4 3.8 10/22/2005 09:00:00 4.5 1 7.2 2.3 4.4 1.1 7.2 2.3 3.7 1 6.1 1.5 43 11 45 255 4 0 4 3.8 10/22/2005 09:10:00 3.1 0.7 4.9 1.1 2.8 0.8 4.6 0.7 2.4 0.8 4.6 0.4 45 15 53 255 4.1 0 4.3 4 10/22/2005 09:20:00 2.1 0.5 3.4 0.4 1.8 0.6 3 0.4 1.5 0.7 3 0.4 22 21 18 255 4.4 0 4.5 4.3 10/22/2005 09:30:00 1.9 0.5 3.4 0.4 1.6 0.5 3 0.4 1.3 0.6 2.6 0.4 14 13 9 255 4.7 0.1 4.8 4.5 10/22/2005 09:40:00 1.3 0.6 2.6 0.4 0.8 0.5 2.6 0.4 0.8 0.5 2.6 0.4 9 27 17 255 4.8 0 5 4.8 10/22/2005 09:50:00 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 12 12 15 255 4.7 0 4.8 4.5 10/22/2005 10:00:00 1.3 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 339 12 6 255 4.9 0 5 4.5 10/22/2005 10:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 11 39 320 255 4.8 0.1 5 4.5 10/22/2005 10:20:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 23 26 356 255 4.6 0 4.8 4.5 10/22/2005 10:30:00 2 0.5 3.4 0.4 1.5 0.6 3.4 0.4 1.5 0.5 2.3 0.4 328 32 308 255 4.8 0 5 4.5 10/22/2005 10:40:00 2.1 0.9 3.8 0.4 1.8 0.8 3.4 0.4 1.6 0.8 3 0.4 312 13 304 255 4.7 0.1 5 4.5 10/22/2005 10:50:00 2.3 0.6 3.8 0.4 1.9 0.8 3.4 0.4 1.9 0.9 3.8 0.4 297 21 284 255 4.4 0 4.5 4.3 10/22/2005 11:00:00 1 0.5 1.9 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.9 0.4 337 22 333 255 4.4 0 4.5 4.3 10/22/2005 11:10:00 1.3 0.7 2.6 0.4 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 338 22 326 255 4.5 0 4.5 4.5 10/22/2005 11:20:00 1.4 0.8 3.4 0.4 1.1 0.7 3 0.4 1 0.7 3 0.4 266 61 347 255 4.6 0 4.8 4.5 10/22/2005 11:30:00 1.9 0.6 3 0.4 1.4 0.6 2.6 0.4 1.4 0.6 3 0.4 296 12 297 255 4.4 0 4.8 4.3 10/22/2005 11:40:00 3 0.6 4.2 1.1 2.6 0.7 4.2 0.7 2.4 0.8 4.2 0.4 293 11 292 255 4.3 0 4.5 4.3 10/22/2005 11:50:00 3.1 1.2 4.9 0.4 2.7 1.3 4.9 0.4 2.6 1.3 4.9 0.4 285 15 288 255 4.3 0 4.5 4.3 10/22/2005 12:00:00 2.1 1 4.2 0.4 1.7 1.1 3.8 0.4 1.6 1 3.8 0.4 282 21 288 255 4.6 0 5 4.5 10/22/2005 12:10:00 2.2 1 4.2 0.4 1.7 1 4.2 0.4 1.7 1 4.6 0.4 299 26 288 255 5.1 0 5.2 4.8 10/22/2005 12:20:00 2.7 0.8 4.9 0.7 2.3 1 4.6 0.4 2.1 0.9 4.2 0.4 310 22 288 255 5.1 0 5.2 5 10/22/2005 12:30:00 2.6 0.9 4.6 0.7 2.2 1 4.2 0.4 2 0.9 4.2 0.4 307 13 314 255 5.2 0 5.5 5 10/22/2005 12:40:00 2.7 0.5 4.2 1.5 2.3 0.5 3.8 0.7 1.9 0.6 3.4 0.4 310 11 314 255 5.2 0 5.2 5 10/22/2005 12:50:00 3.1 0.8 4.9 0.7 2.7 0.8 4.6 0.4 2.5 0.9 4.6 0.4 293 19 272 255 5.2 0 5.5 5 10/22/2005 13:00:00 2.5 0.8 4.2 0.4 2.1 0.9 4.2 0.4 2.1 0.9 4.2 0.4 293 17 303 255 5.3 0 5.7 5 10/22/2005 13:10:00 2.6 1.2 4.6 0.4 2.2 1.2 4.6 0.4 2 1.1 4.6 0.4 301 29 304 255 5.6 0 5.7 5.5 10/22/2005 13:20:00 3 0.7 4.6 1.5 2.5 0.8 4.2 0.7 2.3 0.8 3.8 0.4 309 17 270 255 5.6 0 5.7 5.5 10/22/2005 13:30:00 3 0.6 4.2 1.1 2.7 0.6 3.8 0.7 2.4 0.8 4.2 0.4 295 15 289 255 5.6 0 5.7 5.5 10/22/2005 13:40:00 2.5 0.6 3.8 1.1 2 0.7 3.4 0.4 1.8 0.7 3.4 0.4 295 18 276 255 5.5 0 5.7 5.5 10/22/2005 13:50:00 2.5 0.6 3.8 1.1 2.1 0.7 3.4 0.4 1.9 0.9 4.2 0.4 293 18 270 255 5.4 0 5.7 5.2 10/22/2005 14:00:00 1.6 0.8 3 0.4 1.2 0.7 2.6 0.4 1.2 0.7 3 0.4 307 35 306 255 5.9 0.1 6.2 5.5 10/22/2005 14:10:00 1.6 1 3.8 0.4 1.2 0.9 3.4 0.4 1.4 1 3.4 0.4 279 58 277 255 5.8 0 6 5.7 10/22/2005 14:20:00 2.1 1 4.2 0.4 1.7 1.1 3.8 0.4 1.8 1 3.8 0.4 312 15 308 255 5.7 0 6 5.7 10/22/2005 14:30:00 2.1 0.8 3.8 0.4 1.7 0.9 3.8 0.4 1.6 0.8 3.8 0.4 316 15 319 255 5.9 0 6 5.7 10/22/2005 14:40:00 2.5 0.5 3.8 1.1 2.1 0.6 3.4 0.4 1.9 0.7 3.8 0.4 310 12 312 255 5.8 0 6 5.7 10/22/2005 14:50:00 2.4 0.7 3.8 0.7 1.9 0.8 3.8 0.4 1.8 0.6 3.4 0.7 311 14 298 255 5.7 0 6 5.7 10/22/2005 15:00:00 2.5 0.5 3.8 1.1 2.1 0.6 3.4 0.4 1.8 0.7 3.4 0.4 315 18 313 255 5.7 0 6 5.7 10/22/2005 15:10:00 2.2 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1.7 0.8 3.4 0.4 301 17 292 255 5.7 0 6 5.7 10/22/2005 15:20:00 2.2 0.8 3.8 0.4 1.8 0.9 3.4 0.4 1.7 0.9 3.4 0.4 295 24 309 255 5.8 0 6 5.7 10/22/2005 15:30:00 2.2 0.7 3.8 0.4 1.7 0.8 3.4 0.4 1.6 0.9 3.4 0.4 297 21 309 255 5.7 0 6 5.5 10/22/2005 15:40:00 2.6 0.4 3.8 1.9 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.7 286 19 289 255 5.2 0.1 5.7 5 10/22/2005 15:50:00 2.5 0.7 3.8 1.1 2 0.9 3.8 0.4 1.9 0.8 3.8 0.4 277 19 277 255 4.9 0 5 4.8 10/22/2005 16:00:00 1.4 0.7 3 0.4 0.8 0.6 2.6 0.4 1 0.6 2.6 0.4 286 17 296 255 4.9 0 5 4.8 10/22/2005 16:10:00 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 283 13 287 255 4.9 0 5 4.8 10/22/2005 16:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 261 5 281 255 4.8 0 5 4.8 10/22/2005 16:30:00 1.2 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 245 32 236 255 4.6 0 4.8 4.5 10/22/2005 16:40:00 0.6 0.4 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 289 28 267 255 4.5 0 4.8 4.5 10/22/2005 16:50:00 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 248 23 257 255 4.5 0 4.8 4.5 10/22/2005 17:00:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 280 17 281 255 4.5 0 4.5 4.5 10/22/2005 17:10:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 257 3 276 255 4.3 0 4.5 4.3 10/22/2005 17:20:00 1.1 0.5 2.3 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 284 10 289 255 4.3 0 4.5 4.3 10/22/2005 17:30:00 1.5 0.6 2.6 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 287 13 281 255 4.3 0 4.3 4.3 10/22/2005 17:40:00 1.5 0.7 3.4 0.4 1 0.7 3 0.4 0.9 0.6 2.6 0.4 291 22 270 255 4.2 0 4.3 4 10/22/2005 17:50:00 2.5 0.7 4.2 0.4 2.1 0.8 3.8 0.4 1.6 0.8 3.8 0.4 284 20 299 255 4 0 4.3 4 10/22/2005 18:00:00 2.6 0.8 4.6 0.4 2 0.9 4.2 0.4 1.7 0.8 3.8 0.4 278 23 284 255 4 0 4 3.8 10/22/2005 18:10:00 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 1.2 0.6 3 0.4 293 18 289 255 3.9 0 4 3.8 10/22/2005 18:20:00 1 0.7 3 0.4 0.7 0.5 2.6 0.4 0.6 0.3 1.9 0.4 274 51 303 255 3.8 0 4 3.8 10/22/2005 18:30:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 297 41 308 255 3.6 0 3.8 3.5 10/22/2005 18:40:00 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 223 23 253 255 3.5 0 3.5 3.3 10/22/2005 18:50:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 188 13 200 255 3.4 0 3.5 3.3 10/22/2005 19:00:00 1.8 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1 0.4 2.3 0.4 221 9 212 255 3.3 0 3.5 3.3 10/22/2005 19:10:00 1.4 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.6 0.4 1.9 0.4 203 11 211 255 3.2 0 3.3 3.3 10/22/2005 19:20:00 1.1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 205 8 215 255 3.2 0 3.3 3.3 10/22/2005 19:30:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 260 26 322 255 3.2 0 3.3 3.3 10/22/2005 19:40:00 2 0.5 3 0.7 1.1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 338 9 345 255 3.2 0 3.3 3.3 10/22/2005 19:50:00 1.3 0.5 2.6 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 328 19 339 255 3.2 0 3.3 3.3 10/22/2005 20:00:00 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 331 17 313 255 3.2 0 3.5 3.3 10/22/2005 20:10:00 1.9 0.8 3.8 0.4 1.4 0.9 3.8 0.4 1.2 0.7 2.6 0.4 352 17 3 255 3.2 0 3.3 3.3 10/22/2005 20:20:00 1.2 0.8 3 0.4 0.9 0.7 3 0.4 0.6 0.4 2.6 0.4 348 38 16 255 3.2 0 3.3 3.3 10/22/2005 20:30:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 48 66 7 255 3.2 0 3.3 3 10/22/2005 20:40:00 1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 157 22 133 255 3.1 0 3.3 3 10/22/2005 20:50:00 2.3 1 5.3 0.7 2 1.1 5.3 0.4 1.5 0.9 4.6 0.4 106 21 80 255 3.1 0 3.3 3 10/22/2005 21:00:00 3.6 0.9 6.8 1.9 3.4 1 7.2 1.5 2.7 0.8 5.3 1.1 66 16 77 255 3.5 0.1 3.8 3.3 10/22/2005 21:10:00 4.4 0.8 6.8 2.3 4.3 0.9 6.5 2.3 3.5 0.8 5.7 1.5 54 13 73 255 3.8 0.1 4 3.5 10/22/2005 21:20:00 5.2 1.2 9.1 2.6 5 1.3 8.8 2.6 4.3 1.2 8.4 1.5 42 14 35 255 4.1 0 4.5 4 10/22/2005 21:30:00 7.4 2 14.1 3.4 7.3 2.1 13.7 3.8 6.3 2 12.6 2.6 26 14 19 255 4.7 0.2 5 4.3 10/22/2005 21:40:00 9.4 1.3 13 6.1 9.4 1.3 13 5.3 8.1 1.5 12.2 4.6 28 12 29 255 5.3 0 5.5 5 10/22/2005 21:50:00 9.8 2.4 15.6 4.2 9.8 2.5 16.1 4.6 8.6 2.5 16.8 3.4 39 15 58 255 5.4 0 5.5 5.2 10/22/2005 22:00:00 10.8 1.7 14.9 6.1 10.8 1.7 15.3 6.1 9.3 2 14.9 4.9 35 11 34 255 5.3 0 5.7 5.2 10/22/2005 22:10:00 9.2 2 16.4 4.6 9.2 2 16.1 4.6 8 1.7 14.5 4.2 46 12 62 255 5.1 0 5.5 5 10/22/2005 22:20:00 9.5 1.7 14.1 5.7 9.5 1.7 14.5 5.3 8.1 1.9 13.7 3.4 43 13 42 255 5.2 0 5.5 5 10/22/2005 22:30:00 8.8 1.5 13.7 5.3 8.7 1.6 13.7 4.9 7.6 1.7 13.3 3.4 38 14 58 255 5.5 0.2 5.7 5.2 10/22/2005 22:40:00 8.9 1.7 13.7 4.6 8.9 1.7 13.7 4.6 7.7 1.7 13.3 4.2 41 15 26 255 5.7 0 5.7 5.7 10/22/2005 22:50:00 8.1 1.5 11.8 4.9 8 1.6 12.2 4.6 6.9 1.7 11.5 3.8 39 15 35 255 5.9 0 6 5.7 10/22/2005 23:00:00 6.9 1.3 10.7 3.8 6.8 1.4 10.3 4.2 5.9 1.3 8.8 2.6 36 12 62 255 5.9 0 6 5.7 10/22/2005 23:10:00 8 1.3 12.6 5.3 8 1.4 11.8 4.6 6.6 1.5 11.1 3 32 12 43 255 6.1 0 6.2 6 10/22/2005 23:20:00 9 1.8 14.1 4.6 8.9 1.8 14.1 4.9 7.8 1.8 13 4.6 31 11 39 255 6 0 6 5.7 10/22/2005 23:30:00 10.1 1.8 15.3 6.5 10 1.9 15.3 6.1 8.6 1.8 14.5 4.6 38 12 28 255 6.1 0 6.2 6 10/22/2005 23:40:00 10 2.1 15.6 6.1 10 2.2 16.1 4.9 8.6 2.1 14.9 4.2 35 13 19 255 6.3 0.1 6.5 6.2 10/22/2005 23:50:00 8.3 1.5 12.2 4.9 8.2 1.5 13 4.9 7 1.6 11.5 3.8 31 15 34 255 6.2 0 6.5 6.2 10/23/2005 00:00:00 7.6 1.3 11.1 4.2 7.4 1.3 11.1 4.2 6.5 1.3 10.3 3.4 23 11 44 255 6.1 0 6.5 6 10/23/2005 00:10:00 7.9 1.5 13 3.8 7.8 1.5 13 3.8 6.8 1.5 12.2 3.4 35 13 41 255 6.1 0 6.2 5.7 10/23/2005 00:20:00 6.9 1.3 11.1 4.6 6.7 1.3 11.1 4.2 5.8 1.3 9.5 3 34 10 15 255 6.1 0 6.2 6 10/23/2005 00:30:00 7.6 1.2 10.7 4.9 7.4 1.2 10.7 4.6 6.5 1.3 10.7 3.4 30 10 24 255 6 0 6.2 5.7 10/23/2005 00:40:00 6.3 0.8 8.8 4.2 6.1 0.9 8.8 4.2 5.2 0.9 7.6 2.6 27 11 18 255 5.6 0 6 5.5 10/23/2005 00:50:00 5.5 1.2 8.8 3.4 5.3 1.2 8.4 2.6 4.6 1.1 7.6 2.3 25 11 26 255 5.2 0 5.7 5 10/23/2005 01:00:00 5.2 1.1 8 3 5 1.2 8 2.6 4.3 1.1 7.6 2.3 31 14 30 255 5.1 0 5.2 5 10/23/2005 01:10:00 4.7 1.3 7.6 1.9 4.5 1.3 7.6 1.5 3.9 1.3 6.8 0.7 30 15 34 255 5.2 0 5.5 5 10/23/2005 01:20:00 3 0.8 5.7 1.1 2.6 1 5.3 0.4 2.1 0.9 5.3 0.4 36 21 20 255 4.6 0.1 5 4.3 10/23/2005 01:30:00 2 0.7 4.2 0.4 1.5 0.8 3.8 0.4 1.4 0.6 2.6 0.4 93 26 56 255 4.1 0.3 4.5 3.5 10/23/2005 01:40:00 0.6 0.6 3 0.4 0.5 0.4 2.3 0.4 0.6 0.5 1.9 0.4 29 41 112 255 3.3 0.2 3.5 2.8 10/23/2005 01:50:00 3.3 0.8 4.9 1.1 3 0.9 4.9 0.4 2.4 0.7 3.8 0.7 105 16 104 255 2.7 0.2 3.3 2.3 10/23/2005 02:00:00 1.7 0.6 3.4 0.7 1 0.8 3.4 0.4 1.1 0.5 3 0.4 83 29 105 255 3.3 0 3.5 3 10/23/2005 02:10:00 1.9 0.6 3 0.4 1.3 0.7 2.6 0.4 1 0.5 2.3 0.4 84 12 101 255 2.6 0.3 3.3 2.1 10/23/2005 02:20:00 0.9 0.5 1.9 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 266 90 91 255 1.7 0.2 2.1 1.4 10/23/2005 02:30:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 270 6 274 255 1 0.1 1.4 0.9 10/23/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 96 107 255 255 0.5 0.2 0.9 0.2 10/23/2005 02:50:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 134 15 136 255 0.2 0 0.2 0.2 10/23/2005 03:00:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 100 56 121 255 0.1 0 0.2 -0.1 10/23/2005 03:10:00 1.5 0.6 3 0.4 0.8 0.6 2.6 0.4 1.1 0.7 3 0.4 294 19 296 255 -0.1 0 0.2 -0.1 10/23/2005 03:20:00 1.1 0.7 2.6 0.4 0.7 0.6 2.3 0.4 0.8 0.6 2.3 0.4 299 13 312 255 0 0 0.2 -0.1 10/23/2005 03:30:00 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 302 12 309 255 0.1 0 0.2 -0.1 10/23/2005 03:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 294 51 280 255 -0.3 0.1 -0.1 -0.5 10/23/2005 03:50:00 0.5 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 336 0 336 255 -0.4 0 -0.3 -0.5 10/23/2005 04:00:00 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 3 2 344 255 -0.3 0 -0.1 -0.5 10/23/2005 04:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 51 22 64 255 -0.3 0 -0.1 -0.5 10/23/2005 04:20:00 1.8 0.9 4.6 0.4 1.3 1 4.6 0.4 1.4 0.8 3 0.4 83 30 111 255 -0.5 0 -0.3 -0.5 10/23/2005 04:30:00 4.3 1 6.8 2.3 4.1 1 7.2 1.5 2.7 1 5.3 0.4 107 15 99 255 -0.5 0 -0.3 -0.5 10/23/2005 04:40:00 2.9 1.3 5.7 0.4 2.7 1.5 6.1 0.4 1.4 1.1 4.9 0.4 124 29 106 255 -0.3 0 -0.1 -0.5 10/23/2005 04:50:00 1.2 0.7 3 0.4 1 0.7 3.4 0.4 0.5 0.3 2.3 0.4 116 51 170 255 -0.3 0 -0.1 -0.5 10/23/2005 05:00:00 1.1 0.8 3.8 0.4 0.8 0.7 3.4 0.4 0.4 0.3 2.3 0.4 56 30 118 255 -0.8 0.1 -0.5 -1 10/23/2005 05:10:00 1.8 0.6 3.8 0.7 1.4 0.8 3.4 0.4 0.7 0.4 1.9 0.4 64 39 80 255 -1.1 0 -0.7 -1.2 10/23/2005 05:20:00 2 0.7 3.4 0.4 1.5 0.8 3 0.4 1.3 0.8 3.4 0.4 296 23 286 255 -1.4 0 -1.2 -1.7 10/23/2005 05:30:00 0.9 0.6 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.6 2.6 0.4 326 49 300 255 -1.6 0 -1.4 -1.9 10/23/2005 05:40:00 2.1 0.7 3.8 0.7 1.7 0.9 3.4 0.4 1.1 0.8 3 0.4 26 15 40 255 -1.7 0 -1.4 -1.9 10/23/2005 05:50:00 2.2 0.9 4.2 0.7 1.7 1 4.2 0.4 1.5 0.7 3.8 0.4 48 8 58 255 -1.6 0.2 -1.2 -1.9 10/23/2005 06:00:00 4.4 1 6.5 1.9 4.2 1 6.1 1.5 3.3 0.9 5.3 1.1 81 13 92 255 -1 0 -0.7 -1.2 10/23/2005 06:10:00 5.2 0.6 7.2 3.4 5 0.6 6.8 3 3.8 0.7 5.7 2.3 90 8 93 255 -0.4 0.2 0.2 -0.7 10/23/2005 06:20:00 4.8 0.6 6.1 3.4 4.6 0.6 6.1 2.6 3.6 0.6 5.3 1.9 95 9 88 255 0.7 0.3 1.4 0.2 10/23/2005 06:30:00 5.6 0.7 7.2 3.4 5.4 0.7 6.8 3.4 4.3 0.9 6.5 2.6 104 9 106 255 1.8 0.3 2.3 1.4 10/23/2005 06:40:00 5 0.7 6.8 3 4.8 0.7 6.5 3 3.8 0.8 6.1 1.5 101 11 98 255 2.8 0 2.8 2.3 10/23/2005 06:50:00 4.8 0.6 6.5 3.4 4.6 0.6 6.1 3 3.5 0.7 5.3 1.5 100 8 108 255 2.9 0 3.3 2.8 10/23/2005 07:00:00 4.4 0.7 6.1 2.6 4.3 0.7 6.1 2.6 3.2 0.8 5.7 1.1 97 10 105 255 3 0.1 3.3 2.8 10/23/2005 07:10:00 4.6 0.7 6.8 2.6 4.4 0.7 6.5 2.6 3.5 0.7 6.1 1.9 96 9 102 255 3 0.2 3.5 2.8 10/23/2005 07:20:00 4 0.7 6.1 2.3 3.8 0.7 5.7 1.9 3.1 0.6 4.9 1.5 103 12 120 255 3.6 0.1 4 3.5 10/23/2005 07:30:00 4.4 0.7 6.8 2.6 4.2 0.7 6.5 2.6 3.4 0.8 5.7 1.5 96 11 90 255 3.5 0.2 3.8 3.3 10/23/2005 07:40:00 4.3 0.9 6.8 2.3 4.1 0.9 6.5 1.9 3.3 0.9 6.1 1.1 90 13 105 255 3.3 0.2 3.8 3 10/23/2005 07:50:00 3.4 0.8 5.3 1.1 3.2 0.9 4.9 0.7 2.7 0.8 4.6 0.7 73 17 81 255 3.9 0 4 3.5 10/23/2005 08:00:00 3.8 0.7 5.7 2.3 3.6 0.7 5.7 1.9 2.8 0.6 4.9 1.5 83 13 95 255 3.5 0.2 4 2.8 10/23/2005 08:10:00 4.4 0.8 6.5 2.6 4.2 0.9 6.5 2.3 3.3 0.8 6.1 1.9 93 9 101 255 2.7 0.2 3 2.3 10/23/2005 08:20:00 4.8 0.8 6.8 2.6 4.7 0.7 6.1 2.3 3.6 0.8 5.7 0.7 103 9 105 255 3 0.2 3.5 2.6 10/23/2005 08:30:00 5.4 0.9 8 2.6 5.2 0.9 7.6 1.9 4.2 1 6.5 1.5 110 12 93 255 4.4 0.5 5.2 3.5 10/23/2005 08:40:00 5.2 1 7.2 2.3 5 1 7.2 2.6 4.1 1 6.5 1.1 98 15 108 255 5.3 0 5.5 5.2 10/23/2005 08:50:00 5.1 0.9 8 2.3 5 0.9 7.6 2.6 4.2 1 6.8 1.9 96 11 95 255 5.6 0 5.7 5.5 10/23/2005 09:00:00 4.3 1.1 7.2 1.1 4.1 1.1 7.2 1.1 3.3 1 6.8 0.4 88 16 87 255 5.7 0 5.7 5.7 10/23/2005 09:10:00 4.1 0.7 5.7 2.3 3.9 0.7 5.7 1.9 3.3 0.8 5.3 1.5 91 12 81 255 5.6 0 5.7 5.7 10/23/2005 09:20:00 4.1 0.8 6.5 1.9 3.9 0.8 5.7 1.9 3.4 0.8 5.7 1.5 110 13 113 255 5.8 0.1 6.2 5.7 10/23/2005 09:30:00 4.3 0.9 6.8 1.9 4 1 6.8 1.5 3.6 0.9 6.1 1.5 103 17 80 255 6.6 0.2 6.7 6.2 10/23/2005 09:40:00 5.4 1 8.4 3 5.3 1 8.4 3 4.6 1.1 8.4 2.6 96 11 76 255 6.9 0 7 6.7 10/23/2005 09:50:00 5.5 0.9 8 2.6 5.4 0.9 7.6 2.6 4.8 0.9 6.8 2.6 95 14 69 255 7 0.1 7.3 6.7 10/23/2005 10:00:00 4.4 0.9 7.2 2.3 4.2 1 6.8 2.3 3.7 1 6.1 1.5 88 13 75 255 7.6 0.2 7.8 7.3 10/23/2005 10:10:00 4.5 1 6.8 2.3 4.3 1 6.8 2.3 3.9 1 6.1 1.1 98 12 111 255 8 0 8.3 7.8 10/23/2005 10:20:00 3.8 1 6.1 1.5 3.6 1 6.1 1.1 3.2 0.9 5.3 0.7 90 14 86 255 8.2 0 8.5 8 10/23/2005 10:30:00 4.6 0.9 6.8 2.6 4.4 0.9 6.5 2.3 4 0.9 6.1 1.5 100 13 77 255 8.4 0 8.5 8.3 10/23/2005 10:40:00 5 1 7.2 2.3 4.8 1 6.8 1.9 4.2 1.1 7.2 1.1 103 13 121 255 8.4 0 8.5 8.3 10/23/2005 10:50:00 4.7 1.3 8.4 1.9 4.5 1.3 8.4 1.5 4 1.3 8.4 1.1 85 24 71 255 8.6 0 9 8.5 10/23/2005 11:00:00 5 1.2 8 1.5 4.9 1.2 7.6 1.5 4.3 1.2 7.6 1.9 56 15 91 255 8.8 0 9 8.8 10/23/2005 11:10:00 4.7 1 6.8 2.3 4.6 1 6.8 2.3 4.1 1 6.8 1.5 59 22 70 255 8.7 0 9 8.8 10/23/2005 11:20:00 5.3 0.8 8 3.4 5.2 0.9 8 3 4.6 1 6.8 2.3 45 15 74 255 8.9 0 9 8.8 10/23/2005 11:30:00 5.5 1 8.4 2.6 5.4 1.1 8.8 3 4.7 1.1 7.6 1.9 49 17 53 255 8.5 0.1 9 8.5 10/23/2005 11:40:00 5.6 1.3 9.1 1.9 5.5 1.3 9.1 1.5 4.7 1.2 8 1.9 57 17 52 255 8.3 0 8.5 8.3 10/23/2005 11:50:00 6.8 1.8 11.1 2.6 6.8 1.9 11.5 2.6 5.8 1.9 9.9 1.9 53 17 62 255 8 0 8.3 7.8 10/23/2005 12:00:00 6.3 1.7 11.8 2.6 6.3 1.7 11.8 2.3 5.4 1.5 9.5 1.9 56 15 71 255 8.4 0.1 8.8 8 10/23/2005 12:10:00 8.2 1.4 11.5 3.8 8.2 1.4 11.1 3.4 7.1 1.5 11.1 3.8 37 13 34 255 8.7 0.1 9 8.5 10/23/2005 12:20:00 7.9 1.3 11.1 3.4 7.9 1.4 11.5 3.8 6.9 1.5 11.1 3.4 40 12 48 255 8.9 0 9 8.8 10/23/2005 12:30:00 6.3 1.5 9.9 3 6.3 1.5 9.9 3 5.5 1.6 9.1 1.9 48 17 50 255 9.2 0 9.3 9 10/23/2005 12:40:00 5.5 1.3 9.1 2.6 5.5 1.3 8.8 2.6 4.8 1.3 8.8 1.9 53 17 41 255 9.4 0 9.6 9.3 10/23/2005 12:50:00 6.3 1.5 10.7 3 6.2 1.6 11.1 3 5.4 1.5 9.5 1.9 42 15 43 255 9.2 0 9.3 9 10/23/2005 13:00:00 6.1 1.1 8.4 2.6 6.1 1.1 8.8 2.6 4.9 1.1 8.8 2.6 27 15 27 255 9.2 0 9.3 9 10/23/2005 13:10:00 6.2 1.1 9.1 3.8 6.2 1.2 9.1 3.8 5.4 1.3 10.3 1.9 30 15 43 255 8.9 0 9 8.8 10/23/2005 13:20:00 6.6 1.5 10.3 2.6 6.7 1.4 10.7 3 5.8 1.5 10.3 2.6 47 14 34 255 8.7 0 8.8 8.5 10/23/2005 13:30:00 6.2 1.1 9.1 3.8 6.2 1.1 9.5 3 5.5 1.1 8.4 3 38 14 44 255 8.5 0 8.8 8.5 10/23/2005 13:40:00 6.8 1 10.3 4.2 6.7 1 10.3 4.2 5.8 1.2 8.8 3 34 10 40 255 8.3 0 8.5 8.3 10/23/2005 13:50:00 7.9 1.1 11.5 4.2 8 1.2 11.1 4.6 6.8 1.1 9.1 3.4 35 10 33 255 8.3 0 8.5 8.3 10/23/2005 14:00:00 7.8 1.3 11.5 4.6 7.8 1.3 11.5 4.9 6.8 1.3 10.3 4.2 34 11 30 255 8.5 0 8.8 8.5 10/23/2005 14:10:00 8.8 1.5 13.3 5.3 8.9 1.5 13.3 4.9 7.6 1.5 11.8 4.2 27 12 9 255 8.7 0 8.8 8.5 10/23/2005 14:20:00 8.4 1.3 12.6 4.6 8.4 1.3 12.2 4.9 7.2 1.4 11.1 4.2 31 12 6 255 8.7 0 8.8 8.5 10/23/2005 14:30:00 7.9 1.2 11.5 3.8 7.9 1.3 11.8 4.6 6.8 1.4 9.9 3.8 26 11 27 255 8.5 0 8.8 8.5 10/23/2005 14:40:00 7.7 1.2 10.3 4.2 7.7 1.3 11.1 4.2 6.6 1.3 9.9 3.4 19 9 12 255 8.4 0 8.5 8.3 10/23/2005 14:50:00 7 1.3 10.3 4.2 7 1.3 10.3 4.2 5.5 1.5 9.1 2.6 13 11 17 255 8.1 0 8.3 8 10/23/2005 15:00:00 8.9 1.3 14.1 4.9 8.9 1.4 13.7 5.7 7.4 1.7 12.6 3 20 10 14 255 7.9 0 8 7.8 10/23/2005 15:10:00 10.3 1.8 14.1 5.3 10.4 1.8 14.1 5.3 8.8 1.8 13.3 4.6 22 12 19 255 7.6 0.1 7.8 7.3 10/23/2005 15:20:00 8.4 1.5 12.6 5.3 8.4 1.5 12.6 5.3 7.1 1.5 11.5 3.4 24 13 4 255 7.3 0 7.5 7.3 10/23/2005 15:30:00 8.6 1.3 11.8 5.3 8.6 1.4 12.6 4.9 7 1.5 11.1 3.8 17 10 14 255 7.1 0 7.3 7 10/23/2005 15:40:00 7.7 1.5 12.2 3.8 7.7 1.5 12.6 3.4 6.3 1.7 10.7 3.4 18 12 9 255 7.1 0 7.3 7 10/23/2005 15:50:00 7.8 1.7 12.2 4.2 7.7 1.7 12.6 4.2 6.4 1.9 12.2 2.3 19 12 11 255 6.7 0 7 6.5 10/23/2005 16:00:00 6.8 1.7 11.1 3.4 6.8 1.8 12.2 2.6 5.6 2 11.8 1.5 15 13 16 255 6.4 0 6.7 6.2 10/23/2005 16:10:00 6.5 1.7 13.7 3.4 6.4 1.7 14.1 3.4 5.3 1.6 10.7 2.3 23 15 10 255 6.2 0 6.5 6.2 10/23/2005 16:20:00 7 1.7 12.6 2.6 6.9 1.8 12.6 2.3 5.6 1.7 12.6 1.5 22 17 22 255 6.1 0 6.2 5.7 10/23/2005 16:30:00 7.3 1.5 11.1 3.4 7.3 1.5 11.1 3.4 6.2 1.6 9.9 3 35 14 32 255 5.7 0 6 5.5 10/23/2005 16:40:00 6.8 1.3 9.9 3.4 6.8 1.3 10.3 3.8 5.8 1.3 9.5 3 25 15 55 255 5.4 0 5.7 5.2 10/23/2005 16:50:00 8.9 1.7 14.9 4.6 8.8 1.7 14.5 4.2 7.5 1.8 13.3 3 24 13 32 255 5.3 0 5.5 5.2 10/23/2005 17:00:00 8.8 1.7 13 4.2 8.9 1.8 13 4.6 7.6 1.7 12.2 3.4 29 15 55 255 5.1 0 5.5 5 10/23/2005 17:10:00 9.9 1.7 14.1 5.7 9.9 1.7 14.5 6.1 8.2 1.9 14.1 3.8 25 15 24 255 5.1 0 5 5 10/23/2005 17:20:00 9.7 1.5 14.1 6.1 9.7 1.5 14.5 6.1 8.4 1.7 13.3 4.2 17 12 355 255 4.9 0.1 5 4.8 10/23/2005 17:30:00 5.9 1.3 8.8 2.3 6 1.3 8.8 2.3 4.7 1.3 8.8 1.5 7 15 4 255 4.3 0.2 4.8 4 10/23/2005 17:40:00 4 1 6.8 1.9 4 1 6.8 2.3 3 1.1 6.1 1.1 1 11 350 255 3.8 0.1 4.3 3.5 10/23/2005 17:50:00 3.7 0.7 5.7 2.3 3.5 0.8 5.3 1.9 2.8 0.7 4.9 1.1 334 26 314 255 3.3 0 3.5 3.3 10/23/2005 18:00:00 3.1 1.3 5.3 0.4 2.9 1.4 5.3 0.4 2.5 1.1 4.9 0.4 320 19 328 255 3.2 0 3.3 3 10/23/2005 18:10:00 3.1 0.8 4.9 1.5 2.8 0.8 4.6 1.1 2.3 0.8 4.6 0.4 305 23 291 255 2.8 0.1 3.3 2.6 10/23/2005 18:20:00 2 1.1 4.9 0.4 2 1.1 4.9 0.4 1.7 0.9 4.2 0.4 351 56 273 255 2.3 0 2.6 2.3 10/23/2005 18:30:00 0.9 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.5 1.9 0.4 308 82 251 255 2.1 0.1 2.8 1.8 10/23/2005 18:40:00 1.8 1.3 4.9 0.4 1.8 1.3 4.6 0.4 1.5 1.2 4.6 0.4 322 72 3 255 2.1 0.1 2.6 1.8 10/23/2005 18:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 153 27 101 255 1.5 0.2 2.3 1.4 10/23/2005 19:00:00 0.7 0.7 4.2 0.4 0.7 0.8 4.2 0.4 0.6 0.4 2.6 0.4 153 33 94 255 1 0 1.4 0.9 10/23/2005 19:10:00 2.3 1 4.9 0.4 2.3 1 4.6 0.4 1.6 0.8 4.2 0.4 51 22 67 255 0.9 0.1 1.4 0.7 10/23/2005 19:20:00 4.5 0.8 6.8 1.9 4.4 0.9 6.8 1.9 3.7 0.8 6.5 1.5 37 13 37 255 1.5 0.7 2.8 0.7 10/23/2005 19:30:00 3.9 0.8 5.7 1.5 3.8 0.8 6.1 1.5 3.1 0.9 5.3 1.1 46 12 54 255 3.3 0.1 3.5 2.8 10/23/2005 19:40:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 2.9 0.6 4.9 1.1 48 8 40 255 3.2 0.1 3.5 2.8 10/23/2005 19:50:00 4 0.5 5.3 3 3.9 0.5 4.9 2.6 3.2 0.6 4.6 1.5 26 9 34 255 3 0 3.3 2.8 10/23/2005 20:00:00 3.9 0.8 6.5 1.5 3.8 0.8 6.5 1.1 2.9 0.8 5.3 1.5 13 10 16 255 2.2 0.3 2.8 1.8 10/23/2005 20:10:00 2.2 1 4.6 0.4 2.1 1 4.2 0.4 1.4 0.7 2.6 0.4 11 19 12 255 1.4 0.2 1.8 0.9 10/23/2005 20:20:00 1.3 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.1 0.5 2.3 0.4 228 30 231 255 0.7 0 0.9 0.7 10/23/2005 20:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 192 24 223 255 0.3 0.1 0.7 0.2 10/23/2005 20:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 102 47 85 255 -0.2 0 0.2 -0.3 10/23/2005 20:50:00 1.7 0.5 2.6 0.4 1.6 0.6 2.6 0.4 0.9 0.4 1.9 0.4 100 6 94 255 -0.4 0 -0.1 -0.5 10/23/2005 21:00:00 0.6 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 58 61 92 255 -0.7 0.1 -0.5 -1 10/23/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 0 255 255 -1 0 -0.7 -1.2 10/23/2005 21:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 327 0 327 255 -1.2 0 -1 -1.4 10/23/2005 21:30:00 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 274 102 97 255 -1 0 -1 -1.2 10/23/2005 21:40:00 1.2 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 86 8 105 255 -1.2 0 -1 -1.4 10/23/2005 21:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 82 0 82 255 -1.3 0 -1.2 -1.4 10/23/2005 22:00:00 1.5 0.6 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.3 0.4 94 8 84 255 -1.5 0 -1.2 -1.4 10/23/2005 22:10:00 2.4 0.4 3 1.5 2.2 0.4 3 1.1 1.4 0.4 2.3 0.4 88 6 86 255 -1.6 0 -1.4 -1.7 10/23/2005 22:20:00 1.7 0.3 2.6 1.1 1.4 0.3 2.3 0.7 0.7 0.3 1.5 0.4 105 11 98 255 -1.6 0 -1.4 -1.7 10/23/2005 22:30:00 2.3 0.8 3.4 0.4 2.1 0.8 3.4 0.4 1.3 0.7 2.6 0.4 110 8 105 255 -1.7 0.1 -1.4 -1.9 10/23/2005 22:40:00 1.9 0.5 3 0.4 1.6 0.6 3 0.4 1 0.6 2.6 0.4 124 13 126 255 -1.7 0 -1.4 -1.9 10/23/2005 22:50:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.8 0.4 2.6 0.7 131 7 134 255 -1.8 0 -1.7 -1.9 10/23/2005 23:00:00 3.3 0.5 4.2 1.9 3.1 0.5 4.2 1.5 2.2 0.5 3.8 0.7 119 9 127 255 -1.9 0 -1.9 -2.1 10/23/2005 23:10:00 3.4 0.4 4.6 2.3 3.3 0.5 4.6 2.3 2.3 0.5 3.4 1.1 111 8 106 255 -1.8 0 -1.9 -1.9 10/23/2005 23:20:00 3.7 0.5 4.9 2.3 3.6 0.5 4.6 1.9 2.5 0.6 4.2 1.1 116 9 122 255 -1.6 0 -1.4 -1.9 10/23/2005 23:30:00 3.4 0.5 4.6 1.9 3.1 0.5 4.2 1.5 2.4 0.6 3.8 0.7 111 9 113 255 -1.3 0 -1.2 -1.4 10/23/2005 23:40:00 3.6 0.5 4.9 2.3 3.5 0.5 4.9 2.3 2.5 0.6 4.6 1.1 106 9 108 255 -1.1 0.1 -0.7 -1.4 10/23/2005 23:50:00 3.2 0.7 4.9 1.1 3 0.7 4.9 0.7 2.1 0.6 3.8 0.7 112 11 104 255 -0.6 0.1 -0.5 -0.7 10/24/2005 00:00:00 2.5 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.5 0.7 3 0.4 116 14 123 255 -0.7 0.1 -0.5 -0.7 10/24/2005 00:10:00 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.4 2.3 0.4 126 15 124 255 -1.1 0 -0.7 -1.2 10/24/2005 00:20:00 2 0.7 3.4 0.7 1.8 0.8 3.4 0.4 1.6 0.6 3 0.4 133 12 125 255 -1.2 0 -1 -1.2 10/24/2005 00:30:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 0.4 2.2 0.5 3 0.7 135 10 138 255 -1 0 -1 -1.2 10/24/2005 00:40:00 2.4 0.6 3.8 1.1 2.3 0.6 3.8 1.1 1.9 0.5 3.4 0.4 126 14 108 255 -0.9 0.1 -0.5 -1.2 10/24/2005 00:50:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 1.1 1.7 0.5 3.4 0.4 117 11 113 255 -0.7 0.1 -0.5 -1 10/24/2005 01:00:00 3.1 0.6 4.9 1.5 2.9 0.7 4.9 1.1 2 0.6 4.2 0.4 115 15 105 255 -0.7 0 -0.5 -1 10/24/2005 01:10:00 3.9 0.8 5.7 1.9 3.7 0.8 5.7 1.5 2.8 0.8 4.9 0.7 108 12 109 255 -0.2 0.2 0.2 -0.5 10/24/2005 01:20:00 3.6 0.8 5.3 1.5 3.6 0.8 5.3 1.5 2.6 0.7 4.9 0.7 114 13 102 255 0.1 0 0.2 0.2 10/24/2005 01:30:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 2.3 0.6 4.2 0.7 111 12 112 255 0.1 0 0.2 -0.1 10/24/2005 01:40:00 3.4 0.5 4.6 1.9 3.2 0.6 4.2 1.5 2.5 0.6 4.2 1.1 109 10 110 255 -0.1 0.1 0.2 -0.3 10/24/2005 01:50:00 3.9 0.5 5.3 2.3 3.8 0.5 4.9 2.3 3 0.6 4.6 1.5 105 7 110 255 -0.4 0 -0.1 -0.5 10/24/2005 02:00:00 3.9 0.6 5.3 2.3 3.9 0.6 5.3 2.3 2.8 0.7 4.2 0.7 108 11 119 255 -0.4 0 -0.3 -0.5 10/24/2005 02:10:00 3.9 0.8 5.3 1.5 3.8 0.8 5.7 1.5 2.9 0.7 4.6 1.1 111 12 98 255 -0.3 0 -0.1 -0.5 10/24/2005 02:20:00 3.6 0.8 5.3 1.5 3.5 0.8 5.7 1.5 2.8 0.7 4.9 1.1 122 15 119 255 -0.3 0 -0.1 -0.5 10/24/2005 02:30:00 3.9 0.8 6.1 1.1 3.9 0.8 5.7 1.5 2.9 0.8 4.9 0.7 123 13 98 255 -0.2 0 -0.1 -0.3 10/24/2005 02:40:00 3.9 0.8 6.1 1.9 3.9 0.8 5.7 1.9 3 0.7 4.9 1.1 117 13 113 255 0.1 0 0.2 -0.1 10/24/2005 02:50:00 4.4 0.9 6.5 1.9 4.5 0.8 6.1 2.6 3.5 0.7 4.9 1.9 116 11 123 255 0.1 0 0.2 -0.1 10/24/2005 03:00:00 3.7 0.7 5.3 1.9 3.8 0.7 5.3 1.9 2.9 0.7 4.6 1.5 122 12 119 255 0.1 0 0.2 -0.1 10/24/2005 03:10:00 3.5 0.7 5.3 1.9 3.6 0.7 5.3 1.5 2.7 0.6 4.6 1.5 127 11 120 255 0 0 0.2 -0.1 10/24/2005 03:20:00 3.2 0.7 5.3 1.5 3.2 0.6 5.3 1.5 2.4 0.5 3.8 1.1 129 13 125 255 -0.2 0 -0.1 -0.3 10/24/2005 03:30:00 3.2 0.7 5.3 1.1 3.1 0.8 5.3 1.1 2.5 0.8 4.6 0.7 123 13 131 255 -0.2 0 -0.1 -0.3 10/24/2005 03:40:00 1.9 1.1 4.6 0.4 1.9 1 4.6 0.4 1.5 0.8 3.8 0.4 90 28 108 255 -0.2 0.1 0.2 -0.7 10/24/2005 03:50:00 1.4 1 4.2 0.4 1.3 1 3.8 0.4 0.9 0.8 3.4 0.4 93 28 102 255 -1.2 0.3 -0.5 -1.7 10/24/2005 04:00:00 2.7 0.6 4.2 0.7 2.6 0.6 3.8 1.1 1.7 0.7 3 0.4 102 13 113 255 -1.6 0 -1.4 -1.7 10/24/2005 04:10:00 2.2 0.6 4.2 0.7 2.2 0.6 4.2 0.7 1.4 0.6 3 0.4 94 11 91 255 -1.6 0 -1.4 -1.9 10/24/2005 04:20:00 1.9 0.4 3.4 0.7 1.8 0.4 3 0.7 1 0.5 2.6 0.4 110 15 97 255 -2.2 0.2 -1.7 -2.6 10/24/2005 04:30:00 1.9 0.6 3.4 0.4 1.8 0.6 3 0.4 1.2 0.5 2.6 0.4 116 10 116 255 -2.8 0 -2.6 -2.8 10/24/2005 04:40:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 1.7 0.5 3 0.4 112 9 104 255 -2.8 0 -2.6 -2.8 10/24/2005 04:50:00 2.3 0.4 3.8 1.1 2.1 0.4 3.4 0.7 1.4 0.4 2.6 0.4 109 8 101 255 -2.8 0 -2.6 -3 10/24/2005 05:00:00 3.4 0.6 4.6 1.1 3.3 0.6 4.6 1.1 2.4 0.8 3.8 0.4 104 10 98 255 -2.6 0.2 -2.1 -2.8 10/24/2005 05:10:00 3.4 0.6 4.9 1.5 3.3 0.6 4.6 1.5 2.4 0.7 4.2 0.7 108 12 121 255 -1.8 0.2 -1.4 -2.1 10/24/2005 05:20:00 3.2 0.5 4.2 1.5 3.1 0.4 4.2 1.5 2.3 0.5 3.4 0.7 100 9 109 255 -1.6 0 -1.4 -1.9 10/24/2005 05:30:00 2.9 0.6 4.9 1.5 2.7 0.6 4.2 1.1 1.9 0.6 3.8 0.7 105 11 83 255 -1.7 0.1 -1.4 -2.1 10/24/2005 05:40:00 2.6 0.7 4.2 1.1 2.3 0.8 4.2 0.4 1.5 0.6 3 0.4 115 16 119 255 -2.1 0 -2.1 -2.1 10/24/2005 05:50:00 2.2 0.5 3 0.7 1.9 0.6 3 0.4 1.7 0.5 2.6 0.4 154 14 133 255 -2.2 0.1 -1.9 -2.6 10/24/2005 06:00:00 3 0.4 4.2 1.9 2.9 0.4 4.2 1.9 2.4 0.4 3.4 1.5 142 8 136 255 -2.7 0 -2.4 -2.8 10/24/2005 06:10:00 2.6 0.5 4.2 1.5 2.3 0.5 3.8 0.7 1.7 0.5 3.4 0.4 122 13 136 255 -2.6 0 -2.6 -2.8 10/24/2005 06:20:00 2.3 0.4 3 1.1 2 0.4 3 1.1 1.2 0.5 2.3 0.4 99 5 100 255 -2.8 0.2 -2.4 -3 10/24/2005 06:30:00 3.2 0.4 4.2 1.9 3 0.4 4.2 1.9 2.1 0.5 3.4 0.7 102 6 101 255 -3.1 0 -2.8 -3.3 10/24/2005 06:40:00 3.1 0.4 3.8 2.3 2.9 0.4 3.8 1.9 2.3 0.4 3.8 1.5 98 5 103 255 -3.1 0 -2.8 -3.3 10/24/2005 06:50:00 3.1 0.4 3.8 2.3 2.9 0.4 3.8 1.9 2.2 0.4 3.4 1.1 93 8 93 255 -3.1 0 -3 -3.3 10/24/2005 07:00:00 2.8 0.4 3.4 1.5 2.5 0.4 3.4 1.1 1.7 0.5 2.6 0.4 99 11 90 255 -3.1 0 -3 -3.3 10/24/2005 07:10:00 2.1 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.1 0.6 2.6 0.4 113 15 93 255 -3 0 -2.8 -3.3 10/24/2005 07:20:00 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 129 18 108 255 -3.2 0 -3.3 -3.3 10/24/2005 07:30:00 1.9 0.5 3.4 0.7 1.6 0.5 3 0.4 1 0.4 1.9 0.4 117 9 100 255 -3.2 0 -3.3 -3.3 10/24/2005 07:40:00 1.4 0.6 3 0.4 1.1 0.6 2.6 0.4 0.5 0.4 1.9 0.4 114 13 99 255 -3.5 0 -3.3 -3.5 10/24/2005 07:50:00 1.4 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.3 0.4 136 19 158 255 -3.5 0 -3.3 -3.7 10/24/2005 08:00:00 1.6 0.4 2.6 0.7 1.3 0.4 2.6 0.4 0.8 0.4 2.3 0.4 114 16 113 255 -3.8 0 -3.5 -3.9 10/24/2005 08:10:00 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 110 0 110 255 -4.1 0 -3.9 -4.2 10/24/2005 08:20:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.4 0 0.7 0.4 104 11 110 255 -4 0 -3.9 -4.2 10/24/2005 08:30:00 1.8 0.7 3.4 0.4 1.4 0.8 3.4 0.4 0.9 0.5 2.6 0.4 120 14 119 255 -4 0 -3.9 -4.2 10/24/2005 08:40:00 2.1 0.6 4.2 0.7 1.7 0.8 3.4 0.4 1.4 0.6 3 0.4 133 17 124 255 -4.3 0 -3.9 -4.4 10/24/2005 08:50:00 2.9 0.6 4.6 1.5 2.7 0.7 4.6 1.1 2.1 0.7 4.2 0.7 133 11 124 255 -4.3 0 -4.4 -4.4 10/24/2005 09:00:00 2.6 0.5 4.2 1.5 2.4 0.5 4.2 1.1 1.6 0.5 3 0.7 115 13 127 255 -4.1 0.1 -3.7 -4.4 10/24/2005 09:10:00 3.6 0.6 4.6 1.9 3.4 0.6 4.6 1.9 2.5 0.6 3.8 0.7 113 10 113 255 -3.7 0.1 -3.3 -3.9 10/24/2005 09:20:00 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.3 2.8 0.4 3.8 1.5 88 9 107 255 -2.9 0.2 -2.6 -3.3 10/24/2005 09:30:00 3.2 0.4 3.8 1.9 3 0.4 3.8 1.9 2.2 0.5 3.4 0.7 87 6 82 255 -2.6 0 -2.6 -2.6 10/24/2005 09:40:00 2.9 0.5 4.2 1.9 2.7 0.6 4.2 1.5 1.9 0.6 3 0.4 85 11 98 255 -2.7 0 -2.6 -2.8 10/24/2005 09:50:00 2.8 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.2 0.4 3.4 1.1 81 9 83 255 -2.6 0 -2.6 -2.8 10/24/2005 10:00:00 1.7 0.7 3.8 0.4 1.5 0.8 3.4 0.4 1.3 0.7 3 0.4 71 13 74 255 -2.4 0.1 -2.1 -2.6 10/24/2005 10:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 61 6 48 255 -2.4 0 -2.1 -2.6 10/24/2005 10:20:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 92 19 90 255 -2.4 0 -2.1 -2.6 10/24/2005 10:30:00 1.3 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 118 13 95 255 -2.4 0 -2.1 -2.6 10/24/2005 10:40:00 0.8 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 128 12 140 255 -2.4 0 -2.1 -2.6 10/24/2005 10:50:00 0.8 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 117 21 111 255 -1.9 0.2 -1.4 -2.1 10/24/2005 11:00:00 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 92 22 88 255 -1.2 0.3 -0.7 -1.4 10/24/2005 11:10:00 1.5 0.4 2.6 0.4 1.1 0.4 2.3 0.4 1.2 0.3 1.9 0.4 38 28 74 255 -0.2 0.2 0.2 -0.7 10/24/2005 11:20:00 1.3 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 354 15 358 255 1.1 0.5 2.1 0.2 10/24/2005 11:30:00 1.1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.8 0.4 1.9 0.4 343 19 357 255 2 0 2.3 1.8 10/24/2005 11:40:00 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 344 13 333 255 1.9 0 2.1 1.8 10/24/2005 11:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 358 19 3 255 1.7 0 1.8 1.6 10/24/2005 12:00:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.5 0.4 349 11 2 255 2 0.1 2.3 1.8 10/24/2005 12:10:00 1.5 0.4 2.3 0.4 1.2 0.4 1.9 0.4 1.2 0.5 2.3 0.4 348 16 336 255 2.6 0 2.8 2.3 10/24/2005 12:20:00 1.3 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 2 11 358 255 2.8 0 2.8 2.6 10/24/2005 12:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 352 8 341 255 2.8 0 2.8 2.6 10/24/2005 12:40:00 0.8 0.4 1.5 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 339 22 2 255 2.7 0 2.8 2.6 10/24/2005 12:50:00 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 1.4 0.4 2.6 0.4 355 11 347 255 2.7 0 2.8 2.6 10/24/2005 13:00:00 1.7 0.3 2.6 0.7 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 355 9 355 255 3 0.1 3.3 2.8 10/24/2005 13:10:00 1.7 0.5 2.6 0.7 1.5 0.5 3 0.4 1.2 0.6 2.6 0.4 348 22 348 255 3.4 0.1 3.5 3.3 10/24/2005 13:20:00 1.9 0.5 3 0.4 1.9 0.5 3 0.4 1.6 0.5 3 0.4 298 24 291 255 3.8 0.2 4.3 3.5 10/24/2005 13:30:00 1.9 0.4 3 0.7 1.8 0.5 3 0.7 1.4 0.5 2.6 0.4 314 9 298 255 4.3 0 4.5 4.3 10/24/2005 13:40:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 307 13 313 255 4.5 0.2 5 4.3 10/24/2005 13:50:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1 0.5 2.3 0.4 316 19 321 255 5.1 0 5 4.8 10/24/2005 14:00:00 1.5 0.5 3 0.4 1.3 0.5 3 0.4 1 0.5 2.3 0.4 326 22 305 255 5.1 0 5.2 5 10/24/2005 14:10:00 1.8 0.5 2.6 0.4 1.7 0.4 2.6 0.7 1.4 0.6 2.6 0.4 277 20 280 255 5 0 5.2 4.8 10/24/2005 14:20:00 1.3 0.8 3 0.4 1.2 0.8 3 0.4 1 0.7 2.6 0.4 283 43 257 255 5.1 0.1 5.5 5 10/24/2005 14:30:00 1.9 0.4 3 0.7 1.8 0.4 3 0.7 1.6 0.5 3 0.4 280 17 274 255 5.2 0.1 5.5 4.8 10/24/2005 14:40:00 1.8 0.7 3 0.4 1.8 0.6 3 0.4 1.4 0.7 3 0.4 300 17 297 255 4.7 0 5 4.5 10/24/2005 14:50:00 1.8 0.7 3 0.4 1.8 0.6 3 0.4 1.4 0.7 3.4 0.4 297 23 331 255 4.6 0 4.8 4.5 10/24/2005 15:00:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.7 2.6 0.4 291 21 275 255 4.3 0.2 4.5 4 10/24/2005 15:10:00 2.7 0.5 3.8 0.7 2.7 0.5 3.8 0.4 2.1 0.7 3.4 0.4 302 11 291 255 3.5 0.3 4 3.3 10/24/2005 15:20:00 2.2 0.5 3.4 0.7 2.1 0.6 3.4 0.4 1.8 0.7 3 0.4 306 17 316 255 2.9 0 3.3 2.6 10/24/2005 15:30:00 2.8 0.7 4.9 1.1 2.7 0.8 4.9 0.7 2.1 0.7 4.2 0.4 286 19 283 255 2.3 0 2.8 2.1 10/24/2005 15:40:00 2.4 0.7 3.8 0.4 2.3 0.7 3.8 0.7 1.6 0.8 3.4 0.4 291 17 285 255 2.3 0 2.3 2.1 10/24/2005 15:50:00 2.2 0.9 4.6 0.4 2.2 0.9 4.6 0.4 1.7 0.9 4.2 0.4 285 24 281 255 2 0.1 2.3 1.8 10/24/2005 16:00:00 2 0.8 3.4 0.4 2 0.8 3.8 0.4 1.3 0.9 3.4 0.4 278 30 256 255 1.8 0 1.8 1.6 10/24/2005 16:10:00 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 303 22 323 255 1.6 0.1 1.8 1.4 10/24/2005 16:20:00 1.3 0.7 3 0.4 1.2 0.7 3.4 0.4 0.9 0.6 2.6 0.4 284 17 303 255 1.1 0 1.4 0.9 10/24/2005 16:30:00 1.3 0.7 3 0.4 1.3 0.7 3 0.4 0.9 0.5 2.3 0.4 272 17 253 255 1.1 0 1.4 0.9 10/24/2005 16:40:00 0.5 0.3 1.9 0.4 0.4 0.3 1.9 0.4 0.4 0 0.7 0.4 294 9 302 255 0.5 0 0.9 0.2 10/24/2005 16:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.9 0.5 3 0.4 279 16 291 255 -0.1 0.2 0.4 -0.5 10/24/2005 17:00:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 0.8 0.5 1.9 0.4 262 15 262 255 -0.4 0 -0.3 -0.5 10/24/2005 17:10:00 1.1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.6 0.4 2.3 0.4 265 13 274 255 -1.1 0.2 -0.5 -1.4 10/24/2005 17:20:00 1.2 0.4 2.3 0.4 1.1 0.5 2.3 0.4 0.5 0.2 1.5 0.4 257 5 256 255 -1.6 0 -1.2 -1.4 10/24/2005 17:30:00 1.3 0.4 1.9 0.4 1.3 0.4 1.9 0.4 0.5 0.2 1.1 0.4 249 3 255 255 -1.6 0 -1.4 -1.7 10/24/2005 17:40:00 1.4 0.3 1.9 0.4 1.3 0.3 1.9 0.4 0.4 0.2 1.1 0.4 233 9 222 255 -1.6 0 -1.4 -1.9 10/24/2005 17:50:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 0.4 0.2 1.1 0.4 236 8 241 255 -1.8 0 -1.7 -1.9 10/24/2005 18:00:00 2 0.5 3.4 0.7 1.9 0.5 3 0.4 0.9 0.5 2.6 0.4 226 10 221 255 -2.1 0 -1.9 -2.1 10/24/2005 18:10:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 0.9 0.3 1.5 0.4 216 7 214 255 -2.1 0 -1.9 -2.1 10/24/2005 18:20:00 2.2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1 0.5 2.3 0.4 219 10 229 255 -2.1 0 -1.9 -2.4 10/24/2005 18:30:00 2.5 0.3 3 1.5 2.4 0.4 3.4 1.5 1.3 0.3 2.3 0.7 219 6 216 255 -2.4 0 -2.1 -2.4 10/24/2005 18:40:00 1.9 0.8 3.4 0.4 1.8 0.9 3.4 0.4 0.9 0.5 1.9 0.4 223 7 220 255 -2.4 0 -2.1 -2.6 10/24/2005 18:50:00 1.6 0.8 3 0.4 1.4 0.9 3 0.4 1.4 0.8 2.6 0.4 111 56 89 255 -2.7 0 -2.6 -2.8 10/24/2005 19:00:00 1.2 0.5 3 0.4 0.8 0.6 3 0.4 0.8 0.5 2.3 0.4 111 13 88 255 -3.2 0 -2.8 -3.5 10/24/2005 19:10:00 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 141 8 153 255 -3.1 0 -2.8 -3.3 10/24/2005 19:20:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 160 5 153 255 -3.2 0 -3 -3.3 10/24/2005 19:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 191 32 216 255 -3.3 0 -3.3 -3.5 10/24/2005 19:40:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 245 0 245 255 -3.4 0 -3.3 -3.5 10/24/2005 19:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 237 15 245 255 -3.5 0 -3.3 -3.7 10/24/2005 20:00:00 1.8 0.5 3.4 0.7 1.5 0.6 3 0.4 1 0.5 2.3 0.4 194 12 224 255 -3.8 0 -3.5 -4.2 10/24/2005 20:10:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.4 1.1 0.4 2.3 0.4 189 13 186 255 -4.1 0 -3.9 -4.2 10/24/2005 20:20:00 2.6 0.3 3.4 1.9 2.4 0.3 3.4 1.9 1.5 0.4 2.3 0.7 193 5 193 255 -3.9 0 -3.7 -4.2 10/24/2005 20:30:00 2.6 0.4 3.4 1.5 2.6 0.3 3 1.9 1.3 0.4 2.3 0.4 189 6 211 255 -3.8 0 -3.7 -3.9 10/24/2005 20:40:00 2.4 0.5 3.4 1.1 2.6 0.3 3.4 1.9 1.3 0.4 2.3 0.4 185 9 197 255 -4 0.1 -3.7 -4.2 10/24/2005 20:50:00 2.1 0.8 3.8 0.7 2.2 0.6 3.4 0.4 0.9 0.5 1.9 0.4 184 6 196 255 -4.2 0 -3.9 -4.4 10/24/2005 21:00:00 1.1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.4 0 0.7 0.4 181 4 181 255 -4.5 0 -4.4 -4.6 10/24/2005 21:10:00 0.9 0.4 1.9 0.4 0.9 0.3 1.9 0.4 0.4 0 0.7 0.4 183 3 181 255 -4.6 0 -4.4 -4.6 10/24/2005 21:20:00 1.1 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 156 13 155 255 -4.6 0 -4.4 -4.6 10/24/2005 21:30:00 1.4 0.3 2.3 0.7 1.3 0.3 2.3 0.7 0.7 0.4 1.9 0.4 148 8 146 255 -4.8 0 -4.6 -4.8 10/24/2005 21:40:00 1.8 0.4 2.6 0.7 1.6 0.3 2.3 0.7 0.9 0.4 1.9 0.4 152 9 143 255 -4.8 0 -4.6 -4.8 10/24/2005 21:50:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 171 16 157 255 -4.8 0 -4.6 -5 10/24/2005 22:00:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.6 0.2 1.1 0.4 163 9 172 255 -4.9 0 -4.8 -5 10/24/2005 22:10:00 1.1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 146 4 147 255 -4.9 0 -4.6 -4.8 10/24/2005 22:20:00 1.3 0.4 2.6 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 135 11 111 255 -5 0 -4.8 -5 10/24/2005 22:30:00 2 0.4 3 0.7 1.8 0.5 3 0.7 1.1 0.4 2.3 0.4 124 9 112 255 -5.2 0 -5 -5.3 10/24/2005 22:40:00 1.9 0.4 3 1.1 1.8 0.5 3 0.7 1.1 0.5 2.3 0.4 136 9 143 255 -5.1 0 -5 -5.3 10/24/2005 22:50:00 2.4 0.4 3.4 1.1 2.3 0.5 3 1.1 1.6 0.4 2.6 0.4 135 11 130 255 -5.2 0.1 -5 -5.5 10/24/2005 23:00:00 2.6 0.4 3.4 1.9 2.6 0.4 3.8 1.5 1.9 0.5 3.4 0.7 135 9 136 255 -5.5 0 -5.5 -5.7 10/24/2005 23:10:00 2.6 0.4 3.4 1.5 2.7 0.5 3.4 1.5 2 0.6 3.4 0.4 134 9 127 255 -5.6 0 -5.5 -5.7 10/24/2005 23:20:00 3.2 0.4 4.2 2.3 3.3 0.4 4.6 2.6 2.8 0.6 3.8 0.7 137 8 141 255 -5 0.2 -4.6 -5.5 10/24/2005 23:30:00 2.4 0.6 3.8 1.1 2.4 0.6 3.8 1.1 1.3 0.7 2.6 0.4 145 12 141 255 -4.8 0 -4.6 -5 10/24/2005 23:40:00 1.9 0.5 3 1.1 1.8 0.5 3 0.7 1.1 0.5 2.3 0.4 134 9 131 255 -5.1 0.1 -5 -5.3 10/24/2005 23:50:00 2.9 0.4 3.8 1.9 2.9 0.4 4.2 1.9 2.1 0.5 3.4 1.1 141 10 133 255 -5.4 0 -5 -5.5 10/25/2005 00:00:00 2.1 0.4 3 1.1 2 0.4 3 1.1 1.2 0.4 2.3 0.4 150 8 165 255 -5.4 0 -5.3 -5.5 10/25/2005 00:10:00 1.8 0.5 3 0.7 1.8 0.5 3 0.4 0.8 0.4 1.9 0.4 127 12 139 255 -5.4 0 -5.5 -5.7 10/25/2005 00:20:00 2.1 0.4 3 1.1 2 0.4 3 0.7 1.1 0.5 2.3 0.4 96 6 95 255 -5.4 0 -5.5 -5.5 10/25/2005 00:30:00 1.6 0.4 2.6 0.7 1.5 0.5 2.6 0.7 0.5 0.3 1.9 0.4 93 9 100 255 -5.6 0.1 -5.5 -5.7 10/25/2005 00:40:00 2.2 0.4 3 1.1 2.1 0.4 3 0.7 1.1 0.5 2.3 0.4 112 10 111 255 -5.9 0 -5.7 -5.9 10/25/2005 00:50:00 2.1 0.3 3 1.5 2.1 0.3 3 1.1 1.1 0.4 2.3 0.4 108 9 102 255 -5.6 0 -5.5 -5.7 10/25/2005 01:00:00 2.2 0.3 3 1.1 2.2 0.3 2.6 1.1 1.1 0.3 1.9 0.4 104 6 105 255 -5.8 0 -5.7 -5.9 10/25/2005 01:10:00 2.2 0.3 2.6 1.5 2.2 0.3 3 1.5 1.1 0.4 1.9 0.4 111 8 108 255 -5.8 0 -5.7 -5.7 10/25/2005 01:20:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 1.3 0.4 2.3 0.4 114 11 133 255 -5.8 0 -5.7 -5.7 10/25/2005 01:30:00 2.4 0.4 3.4 0.7 2.4 0.4 3 1.1 1.5 0.4 2.6 0.4 112 10 105 255 -5.6 0 -5.5 -5.7 10/25/2005 01:40:00 2.2 0.5 3.4 0.7 2.2 0.5 3 0.7 1.3 0.4 2.3 0.4 114 11 112 255 -5.7 0 -5.5 -5.7 10/25/2005 01:50:00 2.5 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1.4 0.4 2.3 0.7 112 8 105 255 -5.6 0 -5.5 -5.7 10/25/2005 02:00:00 2.5 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.1 0.4 2.3 0.4 113 8 101 255 -5.7 0 -5.5 -5.7 10/25/2005 02:10:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 1.6 0.5 2.6 0.7 111 8 104 255 -5.8 0 -5.7 -5.9 10/25/2005 02:20:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 1.3 0.5 2.6 0.4 111 9 115 255 -5.8 0 -5.5 -5.9 10/25/2005 02:30:00 2.8 0.4 3.8 1.5 2.7 0.4 3.8 1.1 1.7 0.4 3 0.7 109 8 108 255 -5.9 0 -5.7 -5.9 10/25/2005 02:40:00 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.1 1.9 0.4 2.6 0.7 112 11 93 255 -6 0 -5.9 -6.1 10/25/2005 02:50:00 2.8 0.6 4.2 1.5 2.7 0.6 3.8 1.5 1.6 0.6 3 0.4 111 10 111 255 -6 0 -5.9 -6.1 10/25/2005 03:00:00 3 0.5 4.2 1.5 2.9 0.6 4.2 1.5 1.6 0.6 3 0.4 113 11 105 255 -6.1 0 -5.9 -6.1 10/25/2005 03:10:00 2.8 0.6 4.2 1.1 2.7 0.7 4.2 0.7 1.7 0.5 3 0.4 120 13 115 255 -6.2 0 -5.9 -6.4 10/25/2005 03:20:00 2.6 0.6 4.2 1.5 2.5 0.5 4.2 1.5 1.6 0.5 3.4 0.4 122 12 131 255 -5.9 0 -5.7 -6.1 10/25/2005 03:30:00 2.6 0.6 4.2 1.5 2.6 0.6 4.2 1.1 1.9 0.4 3 0.7 123 14 124 255 -5.7 0 -5.5 -5.7 10/25/2005 03:40:00 2.6 0.5 4.2 1.5 2.6 0.5 3.8 1.1 2.1 0.4 3.4 1.1 129 11 129 255 -5.7 0 -5.5 -5.7 10/25/2005 03:50:00 2.7 0.6 4.6 1.1 2.7 0.7 4.6 1.1 1.6 0.6 3 0.4 120 15 116 255 -5.6 0 -5.5 -5.7 10/25/2005 04:00:00 3 0.6 4.6 1.1 2.9 0.6 4.6 1.5 1.7 0.6 3.4 0.4 115 15 105 255 -5.7 0 -5.5 -5.7 10/25/2005 04:10:00 3 0.7 4.6 1.5 3 0.7 4.6 1.5 1.9 0.7 3.8 0.7 113 14 101 255 -5.9 0 -5.7 -5.9 10/25/2005 04:20:00 3.2 0.7 4.9 1.5 3.1 0.7 4.9 1.5 2 0.6 4.2 0.7 118 13 117 255 -6 0 -5.9 -6.1 10/25/2005 04:30:00 3.3 0.7 4.9 1.5 3.3 0.7 5.3 1.5 2.1 0.6 4.2 0.7 117 13 113 255 -6 0 -5.7 -5.9 10/25/2005 04:40:00 3 0.7 5.3 1.1 3 0.7 4.9 1.5 2 0.6 4.6 0.4 121 14 115 255 -5.9 0 -5.7 -5.9 10/25/2005 04:50:00 3.2 0.7 4.9 1.5 3.2 0.7 4.9 1.5 2.3 0.6 3.8 0.4 122 13 118 255 -5.9 0 -5.7 -5.9 10/25/2005 05:00:00 3.1 0.7 4.6 1.9 3.1 0.7 4.9 1.5 2.3 0.6 4.2 0.7 125 15 136 255 -5.6 0 -5.5 -5.9 10/25/2005 05:10:00 3.4 0.7 5.7 1.5 3.4 0.6 4.9 1.5 2.3 0.7 4.6 0.7 116 14 92 255 -5.5 0 -5.5 -5.7 10/25/2005 05:20:00 3.3 0.7 4.9 1.5 3.2 0.6 4.9 1.5 2.4 0.6 4.9 0.7 121 13 109 255 -5.3 0.1 -5 -5.7 10/25/2005 05:30:00 2.8 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.2 0.5 3.8 0.7 125 13 111 255 -5.2 0 -5 -5.3 10/25/2005 05:40:00 2.8 0.6 4.6 1.1 2.8 0.7 4.2 1.5 2 0.5 3.4 1.1 124 13 119 255 -5.4 0 -5.3 -5.7 10/25/2005 05:50:00 3.2 0.6 4.9 1.9 3.2 0.6 4.6 1.9 2.2 0.5 3.4 1.1 124 10 118 255 -5.7 0 -5.5 -5.7 10/25/2005 06:00:00 2.9 0.6 4.9 1.1 2.9 0.6 4.6 1.5 2.1 0.5 3.8 0.7 125 13 127 255 -5.6 0 -5.5 -5.7 10/25/2005 06:10:00 2.9 0.6 4.2 1.5 2.8 0.5 4.2 1.5 1.9 0.5 3.4 0.7 122 13 117 255 -5.7 0 -5.5 -5.9 10/25/2005 06:20:00 3 0.7 4.6 1.5 2.9 0.7 4.6 1.1 1.8 0.5 3.4 0.4 117 13 103 255 -5.8 0.1 -5.5 -5.9 10/25/2005 06:30:00 2.9 0.7 4.9 1.1 2.8 0.6 4.2 1.1 1.7 0.6 3.4 0.4 116 14 126 255 -6.1 0.1 -5.7 -6.4 10/25/2005 06:40:00 2.8 0.7 4.6 0.7 2.7 0.6 4.2 1.1 1.4 0.7 3.4 0.4 113 13 108 255 -6.3 0 -6.1 -6.4 10/25/2005 06:50:00 2.7 0.6 3.8 1.1 2.5 0.6 3.8 1.1 1.2 0.5 2.3 0.4 113 11 135 255 -6.4 0 -6.1 -6.4 10/25/2005 07:00:00 1.9 0.6 3 0.4 1.6 0.6 3.4 0.4 1.1 0.4 2.3 0.4 125 13 100 255 -6.4 0 -6.1 -6.6 10/25/2005 07:10:00 1.8 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1 0.4 1.9 0.4 122 10 131 255 -6.4 0 -6.1 -6.6 10/25/2005 07:20:00 2.4 0.5 3.4 1.1 2.2 0.6 3.4 1.1 0.7 0.5 2.6 0.4 110 7 108 255 -6.4 0 -6.1 -6.4 10/25/2005 07:30:00 2.6 0.4 3.4 1.1 2.6 0.4 3.4 1.5 1.3 0.5 2.6 0.4 108 9 96 255 -6.4 0 -6.1 -6.6 10/25/2005 07:40:00 2.4 0.5 3.8 1.1 2.3 0.5 3.8 1.1 1.2 0.5 3 0.4 110 11 119 255 -6.8 0.2 -6.6 -7 10/25/2005 07:50:00 2.5 0.4 3.4 1.1 2.4 0.4 3.4 1.1 1 0.5 2.6 0.4 106 11 98 255 -7.1 0 -6.8 -7 10/25/2005 08:00:00 2.3 0.5 3.4 0.7 2.2 0.6 3.4 0.4 1.3 0.4 2.3 0.4 120 13 124 255 -6.8 0 -6.6 -7 10/25/2005 08:10:00 2.5 0.6 3.8 1.1 2.4 0.6 3.8 1.1 1.8 0.5 3 0.4 123 11 102 255 -6.8 0 -6.8 -7 10/25/2005 08:20:00 2.7 0.7 4.2 1.1 2.7 0.7 4.6 0.7 1.5 0.5 3.4 0.4 117 13 106 255 -6.7 0 -6.6 -6.8 10/25/2005 08:30:00 1.4 0.4 2.6 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 117 13 115 255 -6.7 0 -6.6 -6.8 10/25/2005 08:40:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 138 10 132 255 -6.5 0 -6.6 -6.6 10/25/2005 08:50:00 1.4 0.4 2.3 0.7 1.2 0.5 2.6 0.4 1.1 0.4 1.9 0.4 133 9 134 255 -6.4 0.1 -6.1 -6.6 10/25/2005 09:00:00 1.6 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 139 8 149 255 -6 0 -5.9 -6.1 10/25/2005 09:10:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.8 0.3 1.5 0.4 117 9 108 255 -5.9 0 -5.7 -5.9 10/25/2005 09:20:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.6 0.3 1.9 0.4 118 15 106 255 -5.6 0 -5.5 -5.7 10/25/2005 09:30:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 0.7 0.3 1.5 0.4 123 15 105 255 -5 0.1 -4.8 -5.5 10/25/2005 09:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 147 20 105 255 -4.6 0 -4.4 -4.8 10/25/2005 09:50:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 167 11 156 255 -4.3 0 -3.9 -4.4 10/25/2005 10:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 155 15 148 255 -3.8 0.2 -3.5 -4.2 10/25/2005 10:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 143 0 142 255 -3.2 0.1 -2.8 -3.5 10/25/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 152 26 255 255 -2.8 0 -2.6 -3 10/25/2005 10:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 219 0 219 255 -2.5 0 -2.1 -2.6 10/25/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 219 0 255 255 -2 0.1 -1.7 -2.4 10/25/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 219 0 255 255 -1.6 0 -1.2 -1.9 10/25/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 255 56 255 255 -1.2 0.1 -0.7 -1.4 10/25/2005 11:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 343 0 255 255 -0.9 0 -0.7 -1 10/25/2005 11:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 326 49 343 255 -0.3 0.2 0.2 -0.7 10/25/2005 11:30:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 253 90 341 255 0.3 0.1 0.7 -0.1 10/25/2005 11:40:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 347 13 333 255 -0.1 0 0.2 -0.3 10/25/2005 11:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 347 16 353 255 -0.2 0 -0.1 -0.3 10/25/2005 12:00:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.3 1.9 0.4 348 13 1 255 0.1 0 0.2 -0.1 10/25/2005 12:10:00 1.1 0.4 1.9 0.4 1 0.4 2.3 0.4 1.3 0.3 1.9 0.4 359 8 7 255 0.1 0 0.2 -0.1 10/25/2005 12:20:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.9 0.5 2.3 0.4 348 6 347 255 0.1 0 0.2 -0.1 10/25/2005 12:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.3 1.5 0.4 357 7 10 255 0.1 0 0.2 -0.1 10/25/2005 12:40:00 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 8 13 10 255 0.1 0 0.2 -0.1 10/25/2005 12:50:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 7 6 14 255 0 0 0.2 -0.1 10/25/2005 13:00:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1 0.5 1.9 0.4 6 8 16 255 0 0 0.2 -0.1 10/25/2005 13:10:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 4 4 13 255 -0.1 0 0.2 -0.3 10/25/2005 13:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 12 11 32 255 -0.1 0 -0.1 -0.3 10/25/2005 13:30:00 1.2 0.3 2.3 0.4 1.2 0.4 1.9 0.4 1.2 0.3 2.3 0.4 26 9 7 255 0.1 0 0.4 -0.1 10/25/2005 13:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 37 9 32 255 0.9 0.2 1.4 0.4 10/25/2005 13:50:00 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 59 12 27 255 1.7 0.1 2.1 1.4 10/25/2005 14:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 42 18 21 255 2.3 0.1 2.6 1.8 10/25/2005 14:10:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.4 2.3 0.4 32 12 28 255 2.5 0 2.6 2.3 10/25/2005 14:20:00 1.3 0.3 1.9 0.4 1.3 0.3 1.9 0.7 1.2 0.4 2.3 0.4 3 20 27 255 2.7 0.2 3.3 2.6 10/25/2005 14:30:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 359 16 6 255 3.1 0.1 3.3 2.8 10/25/2005 14:40:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 356 10 348 255 2.7 0 2.8 2.6 10/25/2005 14:50:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 346 15 6 255 2.9 0 2.8 2.8 10/25/2005 15:00:00 1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 357 10 353 255 2.6 0.2 2.8 2.3 10/25/2005 15:10:00 1.2 0.3 2.3 0.4 1.4 0.3 2.3 0.7 1 0.4 2.3 0.4 1 11 7 255 1.9 0.1 2.3 1.8 10/25/2005 15:20:00 1.8 0.4 3 0.7 1.9 0.4 3 0.7 1.5 0.6 2.6 0.4 9 11 14 255 1.5 0.1 1.8 1.4 10/25/2005 15:30:00 1.5 0.5 2.6 0.4 1.7 0.4 2.6 0.7 1.4 0.4 2.6 0.4 8 10 8 255 1.2 0 1.4 0.9 10/25/2005 15:40:00 0.9 0.5 1.9 0.4 1.1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 343 19 16 255 0.8 0.1 1.1 0.7 10/25/2005 15:50:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.4 2.3 0.4 336 22 348 255 0.7 0 0.9 0.7 10/25/2005 16:00:00 1.2 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.7 0.5 2.3 0.4 347 12 345 255 0.5 0 0.7 0.2 10/25/2005 16:10:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 346 6 351 255 0.2 0 0.4 -0.1 10/25/2005 16:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 337 11 336 255 0 0 0.2 -0.1 10/25/2005 16:30:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 337 9 353 255 -0.1 0 -0.1 -0.3 10/25/2005 16:40:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 299 15 289 255 -0.3 0 -0.1 -0.5 10/25/2005 16:50:00 0.7 0.3 1.1 0.4 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 302 8 288 255 -0.5 0 -0.3 -0.7 10/25/2005 17:00:00 1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 286 13 294 255 -0.8 0.1 -0.5 -1 10/25/2005 17:10:00 0.9 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.5 0.2 1.5 0.4 287 11 295 255 -1.1 0 -1 -1.2 10/25/2005 17:20:00 1.2 0.2 1.9 0.4 1.1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 289 4 294 255 -1.4 0 -1.2 -1.4 10/25/2005 17:30:00 1 0.2 1.5 0.4 1 0.2 1.5 0.4 0.4 0 0.7 0.4 285 0 286 255 -1.7 0.2 -1.4 -2.1 10/25/2005 17:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 285 0 285 255 -1.9 0 -1.9 -2.1 10/25/2005 17:50:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 283 5 271 255 -2 0 -1.9 -2.1 10/25/2005 18:00:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 256 5 270 255 -2.1 0 -2.1 -2.1 10/25/2005 18:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 252 0 252 255 -2.1 0 -2.1 -2.4 10/25/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 255 255 -2.3 0 -2.1 -2.6 10/25/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 255 255 -2.5 0 -2.4 -2.6 10/25/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 255 255 -2.5 0 -2.4 -2.6 10/25/2005 18:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 252 255 -2.6 0 -2.6 -2.6 10/25/2005 19:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 252 255 -2.7 0 -2.6 -2.8 10/25/2005 19:10:00 0.5 0.2 1.1 0.4 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 252 0 252 255 -2.7 0 -2.6 -2.8 10/25/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 255 255 -2.7 0 -2.6 -2.8 10/25/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 255 255 -2.8 0 -2.6 -2.8 10/25/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 255 255 -2.9 0 -2.8 -3 10/25/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 252 0 255 255 -2.9 0 -2.8 -3 10/25/2005 20:00:00 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 180 86 255 255 -3 0 -2.8 -3 10/25/2005 20:10:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 82 0 255 255 -3 0 -2.8 -3.3 10/25/2005 20:20:00 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 82 0 82 255 -3.1 0 -3 -3.3 10/25/2005 20:30:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 84 7 83 255 -3.3 0 -3.3 -3.3 10/25/2005 20:40:00 0.7 0.5 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 139 58 118 255 -3.5 0.1 -3.3 -3.7 10/25/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 0 255 255 -3.8 0 -3.5 -3.9 10/25/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 0 255 255 -4.2 0.1 -3.9 -4.4 10/25/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 0 255 255 -4.1 0 -3.9 -4.2 10/25/2005 21:20:00 1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.7 0.2 1.1 0.4 269 64 244 255 -4.1 0 -3.9 -4.4 10/25/2005 21:30:00 1.3 0.4 2.6 0.7 1.2 0.4 2.6 0.4 0.7 0.4 1.9 0.4 71 2 70 255 -4.3 0 -4.4 -4.4 10/25/2005 21:40:00 2 0.4 3 1.1 1.9 0.4 2.6 1.1 1.3 0.3 2.3 0.4 77 7 80 255 -4.3 0 -4.4 -4.4 10/25/2005 21:50:00 1.5 0.2 2.3 0.7 1.3 0.3 1.9 0.7 0.9 0.4 1.5 0.4 79 2 78 255 -4.3 0 -4.4 -4.6 10/25/2005 22:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 78 0 78 255 -4.5 0 -4.4 -4.6 10/25/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 0 255 255 -4.4 0 -4.4 -4.6 10/25/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 107 24 255 255 -4.3 0 -4.4 -4.4 10/25/2005 22:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.1 0.4 1.9 0.4 153 12 168 255 -4.4 0 -4.4 -4.6 10/25/2005 22:40:00 1.1 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 125 9 133 255 -4.5 0 -4.4 -4.6 10/25/2005 22:50:00 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 106 5 106 255 -4.4 0 -4.4 -4.6 10/25/2005 23:00:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.7 0.3 1.5 0.4 103 6 106 255 -4.3 0 -4.2 -4.4 10/25/2005 23:10:00 1.2 0.3 1.9 0.7 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 80 8 87 255 -4.2 0 -3.9 -4.4 10/25/2005 23:20:00 0.9 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 78 7 73 255 -4 0 -3.9 -4.2 10/25/2005 23:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 125 12 117 255 -4 0 -3.9 -3.9 10/25/2005 23:40:00 1.5 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.6 0.3 1.5 0.4 104 5 100 255 -4.2 0 -3.9 -4.4 10/25/2005 23:50:00 1.9 0.2 2.3 1.1 1.8 0.2 2.3 1.1 0.7 0.3 1.5 0.4 92 11 104 255 -4.3 0 -4.2 -4.6 10/26/2005 00:00:00 1.9 0.2 2.3 1.1 1.7 0.2 2.3 1.1 0.9 0.3 1.5 0.4 87 4 82 255 -4.4 0 -4.4 -4.6 10/26/2005 00:10:00 2 0.3 2.6 1.5 1.7 0.3 2.3 1.1 0.9 0.4 1.9 0.4 97 5 105 255 -4.3 0 -4.2 -4.4 10/26/2005 00:20:00 2.4 0.3 3 1.9 2.2 0.3 2.6 1.5 1.1 0.4 1.9 0.4 95 5 88 255 -4.4 0 -4.4 -4.6 10/26/2005 00:30:00 2 0.3 2.6 0.7 1.8 0.3 2.3 0.7 0.9 0.3 1.9 0.4 104 10 104 255 -4.8 0.1 -4.4 -5 10/26/2005 00:40:00 2.1 0.5 3.4 1.1 1.8 0.6 3 0.7 1.3 0.5 2.6 0.4 117 15 101 255 -5.2 0.1 -5 -5.5 10/26/2005 00:50:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1 0.5 2.6 0.4 105 17 103 255 -5.3 0 -5.3 -5.5 10/26/2005 01:00:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 117 23 100 255 -5.4 0 -5.3 -5.7 10/26/2005 01:10:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1 0.4 2.6 0.4 115 13 115 255 -5.5 0 -5.5 -5.7 10/26/2005 01:20:00 2.1 0.4 3 1.1 2 0.5 3 0.7 1 0.4 2.6 0.4 110 9 104 255 -5.7 0 -5.5 -5.7 10/26/2005 01:30:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 1.1 0.5 2.3 0.4 110 11 104 255 -5.6 0 -5.5 -5.7 10/26/2005 01:40:00 2 0.3 2.6 1.5 1.9 0.4 2.6 1.1 1 0.4 1.9 0.4 103 10 90 255 -5.7 0 -5.5 -5.9 10/26/2005 01:50:00 2.2 0.5 3 1.1 2.1 0.5 3 0.7 1.2 0.5 2.3 0.4 106 20 105 255 -5.9 0 -5.7 -5.9 10/26/2005 02:00:00 1.9 0.4 3 1.1 1.7 0.4 3 0.7 1.1 0.4 2.3 0.4 106 13 113 255 -5.9 0 -5.7 -5.9 10/26/2005 02:10:00 2.4 0.6 3.4 1.1 2.2 0.6 3.4 0.7 1.6 0.5 3.4 0.4 120 13 105 255 -5.9 0 -5.7 -5.9 10/26/2005 02:20:00 2 0.4 3 1.1 1.9 0.4 2.6 0.4 1.2 0.5 2.6 0.4 110 17 103 255 -5.9 0 -5.7 -5.9 10/26/2005 02:30:00 2 0.7 3.8 0.7 1.7 0.9 3.4 0.4 1.3 0.8 3 0.4 114 12 121 255 -5.9 0 -5.7 -5.9 10/26/2005 02:40:00 2.1 0.5 3.4 1.1 1.9 0.6 3.8 0.7 1.1 0.5 2.3 0.4 101 11 110 255 -6 0 -5.9 -6.1 10/26/2005 02:50:00 2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.2 0.8 3.8 0.4 120 12 138 255 -6 0 -5.9 -6.1 10/26/2005 03:00:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.4 0.4 2.3 0.4 113 12 101 255 -6.1 0 -6.1 -6.4 10/26/2005 03:10:00 2 0.6 3.8 0.7 1.8 0.6 3.8 0.4 1 0.6 2.6 0.4 110 21 119 255 -6.4 0 -6.1 -6.6 10/26/2005 03:20:00 2 0.5 3.8 1.1 2 0.5 3.4 0.7 1.3 0.6 2.6 0.4 105 17 100 255 -6.5 0 -6.4 -6.6 10/26/2005 03:30:00 2 0.4 3.4 0.7 1.9 0.4 3 0.7 1 0.6 2.6 0.4 101 16 121 255 -6.5 0 -6.4 -6.6 10/26/2005 03:40:00 1.7 0.4 3 0.4 1.7 0.4 3.4 0.4 1.1 0.4 2.3 0.4 105 20 155 255 -6.5 0 -6.4 -6.6 10/26/2005 03:50:00 1.7 0.5 3 0.7 1.6 0.5 3 0.7 0.6 0.3 1.5 0.4 100 14 109 255 -6.6 0 -6.6 -6.8 10/26/2005 04:00:00 2.1 0.7 3.8 0.7 2.1 0.7 3.8 0.7 1.1 0.6 3 0.4 110 18 105 255 -6.7 0 -6.6 -6.8 10/26/2005 04:10:00 1.2 0.6 2.6 0.4 1.1 0.7 2.6 0.4 0.6 0.4 1.5 0.4 117 17 120 255 -6.8 0 -6.6 -6.8 10/26/2005 04:20:00 1.9 0.7 3 0.4 1.7 0.7 3 0.4 0.9 0.5 2.6 0.4 115 10 120 255 -6.9 0.1 -6.6 -7 10/26/2005 04:30:00 1.7 0.6 3 0.4 1.5 0.7 3 0.4 0.7 0.4 2.3 0.4 103 14 113 255 -7.1 0 -6.8 -7 10/26/2005 04:40:00 1.6 0.7 3.4 0.4 1.4 0.7 3 0.4 1 0.6 2.6 0.4 99 24 105 255 -6.9 0.1 -6.8 -7 10/26/2005 04:50:00 1.9 0.7 3 0.4 1.8 0.7 3 0.4 1.1 0.5 2.3 0.4 103 7 108 255 -6.9 0 -6.8 -7 10/26/2005 05:00:00 1.9 0.3 2.6 0.7 1.8 0.3 2.3 0.7 1 0.5 2.3 0.4 103 20 126 255 -7 0 -6.8 -7.2 10/26/2005 05:10:00 2.2 0.3 3 1.5 2.2 0.3 3 1.1 1.4 0.5 2.6 0.4 95 15 103 255 -7.2 0 -7 -7.2 10/26/2005 05:20:00 1.9 0.4 3 1.1 1.8 0.4 3 0.7 1.1 0.5 2.3 0.4 107 17 102 255 -7.2 0 -7 -7.2 10/26/2005 05:30:00 1.8 0.6 3 0.4 1.6 0.6 3 0.4 1 0.5 2.6 0.4 105 20 100 255 -7.2 0 -7 -7.2 10/26/2005 05:40:00 2.4 0.7 3.8 1.1 2.3 0.7 3.8 0.7 1.2 0.6 3 0.4 106 13 106 255 -7.3 0 -7 -7.2 10/26/2005 05:50:00 2.5 0.7 3.8 1.1 2.4 0.7 3.8 1.1 1.5 0.8 3 0.4 79 13 92 255 -7.5 0 -7.2 -7.6 10/26/2005 06:00:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 94 49 39 255 -7.5 0 -7.2 -7.6 10/26/2005 06:10:00 2.2 0.7 3.4 0.7 2 0.8 3.4 0.4 1.3 0.6 2.6 0.4 102 13 92 255 -7.6 0 -7.4 -7.6 10/26/2005 06:20:00 2 0.4 3 1.1 1.9 0.4 2.6 0.7 0.8 0.5 1.9 0.4 83 18 100 255 -7.5 0 -7.4 -7.6 10/26/2005 06:30:00 2.1 0.5 3.4 1.1 1.9 0.5 3.4 0.7 0.8 0.5 2.6 0.4 93 15 93 255 -7.7 0 -7.6 -7.9 10/26/2005 06:40:00 1.7 0.4 2.6 1.1 1.5 0.4 2.6 0.7 0.9 0.6 2.6 0.4 100 19 118 255 -7.6 0 -7.4 -7.6 10/26/2005 06:50:00 1.3 0.3 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.6 2.6 0.4 91 28 80 255 -7.7 0 -7.6 -7.9 10/26/2005 07:00:00 1.3 0.4 3 0.4 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 94 33 153 255 -7.9 0 -7.6 -8.1 10/26/2005 07:10:00 1.2 0.3 1.9 0.7 0.7 0.4 1.9 0.4 0.6 0.4 2.3 0.4 117 15 93 255 -7.7 0 -7.6 -8.1 10/26/2005 07:20:00 1.7 0.3 2.3 1.1 1.4 0.3 1.9 0.4 1.2 0.4 2.3 0.4 103 15 106 255 -7.7 0 -7.6 -7.6 10/26/2005 07:30:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.4 1.1 0.6 2.6 0.4 112 18 104 255 -7.8 0 -7.6 -7.9 10/26/2005 07:40:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 0.8 0.6 2.6 0.4 98 22 129 255 -7.9 0 -7.6 -8.1 10/26/2005 07:50:00 1.5 0.3 2.3 0.4 1.3 0.4 1.9 0.4 0.6 0.4 2.3 0.4 107 12 106 255 -8 0 -7.9 -8.1 10/26/2005 08:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 108 23 148 255 -8 0 -7.9 -8.1 10/26/2005 08:10:00 1.6 0.4 2.6 0.7 1.5 0.4 2.6 0.7 0.8 0.4 2.3 0.4 92 20 88 255 -8.1 0 -8.1 -8.1 10/26/2005 08:20:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 66 10 71 255 -8.1 0 -8.1 -8.1 10/26/2005 08:30:00 1.9 0.4 2.6 1.1 1.8 0.5 2.6 0.4 0.9 0.4 2.3 0.4 91 5 89 255 -8.1 0 -8.1 -8.1 10/26/2005 08:40:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 0.7 0.3 1.5 0.4 109 9 122 255 -8.1 0 -8.1 -8.1 10/26/2005 08:50:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 92 13 99 255 -8.1 0 -7.9 -8.1 10/26/2005 09:00:00 1.9 0.3 2.6 1.1 1.7 0.4 2.3 0.7 0.7 0.3 1.5 0.4 103 12 96 255 -8 0 -7.9 -8.1 10/26/2005 09:10:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.2 1.5 0.4 108 21 93 255 -8 0 -7.9 -8.1 10/26/2005 09:20:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 105 9 109 255 -7.7 0.1 -7.2 -8.1 10/26/2005 09:30:00 1.6 0.7 3 0.4 1.3 0.8 3 0.4 1 0.6 2.6 0.4 92 22 103 255 -6.8 0.2 -6.6 -7.2 10/26/2005 09:40:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.9 0.7 3 0.4 101 49 106 255 -6.3 0 -6.1 -6.6 10/26/2005 09:50:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 105 38 156 255 -5.9 0.2 -5.5 -6.1 10/26/2005 10:00:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 122 35 134 255 -4.9 0.3 -4.4 -5.5 10/26/2005 10:10:00 1 0.8 2.6 0.4 0.9 0.7 2.6 0.4 0.7 0.5 2.3 0.4 27 38 77 255 -3.8 0.2 -3.5 -4.4 10/26/2005 10:20:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 15 18 34 255 -3.1 0.2 -2.6 -3.5 10/26/2005 10:30:00 1 0.5 1.9 0.4 0.8 0.5 1.5 0.4 0.7 0.5 1.9 0.4 17 7 34 255 -2.9 0 -2.8 -3 10/26/2005 10:40:00 1 0.3 2.3 0.4 0.7 0.4 1.9 0.4 0.7 0.3 1.5 0.4 7 23 36 255 -2.6 0.1 -2.4 -2.8 10/26/2005 10:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 3 23 50 255 -2.4 0 -2.1 -2.6 10/26/2005 11:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 8 9 3 255 -2.4 0 -2.1 -2.6 10/26/2005 11:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 359 36 8 255 -2.3 0 -1.9 -2.6 10/26/2005 11:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.3 1.5 0.4 24 47 86 255 -1.6 0.2 -1.2 -2.1 10/26/2005 11:30:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 7 28 31 255 -0.9 0 -0.7 -1.2 10/26/2005 11:40:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 353 22 348 255 -1 0 -0.7 -1 10/26/2005 11:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 8 21 336 255 -0.9 0 -0.7 -1.2 10/26/2005 12:00:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.3 1.5 0.4 359 14 352 255 -0.5 0.1 -0.1 -0.7 10/26/2005 12:10:00 1.1 0.4 1.9 0.4 0.7 0.4 2.3 0.4 0.9 0.3 1.5 0.4 353 15 333 255 0.2 0.3 0.7 -0.3 10/26/2005 12:20:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.9 0.4 327 15 309 255 1.1 0.3 1.6 0.7 10/26/2005 12:30:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 321 17 315 255 1.2 0.1 1.6 0.9 10/26/2005 12:40:00 2 0.3 2.6 1.1 1.9 0.4 2.6 1.1 1.8 0.4 3 0.7 314 8 318 255 0.9 0 1.1 0.9 10/26/2005 12:50:00 1.7 0.3 2.6 0.7 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 322 12 324 255 1 0 1.4 0.9 10/26/2005 13:00:00 2.1 0.5 3 0.7 1.9 0.5 3 0.4 1.5 0.6 2.6 0.4 319 22 304 255 1.4 0.1 1.8 1.1 10/26/2005 13:10:00 2.3 0.5 3.4 0.7 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 325 16 310 255 1.8 0 1.8 1.6 10/26/2005 13:20:00 2 0.4 3 1.1 1.8 0.5 3.4 0.7 1.6 0.6 3 0.4 317 17 291 255 1.8 0 2.1 1.8 10/26/2005 13:30:00 2 0.6 3 0.4 1.9 0.6 3 0.4 1.6 0.6 2.6 0.4 308 23 321 255 2 0.1 2.3 1.8 10/26/2005 13:40:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.4 0.7 3 0.4 287 26 290 255 2.4 0 2.6 2.3 10/26/2005 13:50:00 1.7 0.6 3.4 0.4 1.6 0.7 3 0.4 1.2 0.6 2.6 0.4 327 29 321 255 2.7 0.1 3.3 2.6 10/26/2005 14:00:00 1.3 0.8 3.4 0.4 1.4 0.8 3 0.4 1 0.7 3.4 0.4 263 23 280 255 3.2 0.1 3.5 2.8 10/26/2005 14:10:00 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 1.2 0.6 3 0.4 267 18 270 255 2.3 0.2 2.8 1.8 10/26/2005 14:20:00 2 0.5 3 0.4 1.9 0.5 3 0.4 1.4 0.7 3 0.4 271 18 268 255 1.6 0.2 2.1 1.4 10/26/2005 14:30:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.6 2.6 0.4 296 15 299 255 1.8 0.1 2.1 1.4 10/26/2005 14:40:00 2.2 0.5 3.4 0.4 2.2 0.5 3.4 0.4 1.7 0.5 3 0.4 309 10 317 255 1.8 0 1.8 1.8 10/26/2005 14:50:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 1.8 0.6 3.4 0.4 304 15 305 255 1.8 0 1.8 1.8 10/26/2005 15:00:00 2.2 0.6 3.8 0.4 2 0.6 4.2 0.4 1.6 0.7 3.8 0.4 296 19 309 255 1.7 0.1 2.1 1.4 10/26/2005 15:10:00 2.6 0.6 4.2 0.7 2.6 0.6 4.2 0.4 2.2 0.7 3.8 0.4 287 17 282 255 1.1 0.1 1.4 0.9 10/26/2005 15:20:00 2 0.5 3.4 0.4 2 0.5 3 0.7 1.5 0.5 2.6 0.4 294 16 303 255 0.6 0 0.9 0.2 10/26/2005 15:30:00 1.9 0.5 3 0.4 1.9 0.6 3 0.4 1.4 0.7 3 0.4 308 13 315 255 0.1 0 0.4 -0.1 10/26/2005 15:40:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 314 17 306 255 -0.1 0 0.2 -0.1 10/26/2005 15:50:00 1.7 0.4 2.6 0.7 1.3 0.4 2.3 0.4 1 0.6 2.6 0.4 327 17 336 255 -0.4 0 -0.1 -0.7 10/26/2005 16:00:00 1.6 0.5 2.6 0.4 1.1 0.4 2.3 0.4 1 0.5 2.3 0.4 339 10 314 255 -0.9 0.1 -0.5 -1 10/26/2005 16:10:00 2 0.6 3 0.4 1.5 0.5 2.6 0.4 1.4 0.6 3 0.4 332 10 338 255 -1.2 0.1 -1 -1.4 10/26/2005 16:20:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 327 12 327 255 -1.6 0 -1.2 -1.9 10/26/2005 16:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.5 0.4 306 24 318 255 -2 0 -1.7 -2.1 10/26/2005 16:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 275 0 275 255 -2.1 0 -1.9 -2.1 10/26/2005 16:50:00 0.6 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 301 23 322 255 -2.3 0.1 -2.1 -2.6 10/26/2005 17:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 4 47 315 255 -2.6 0 -2.4 -2.8 10/26/2005 17:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 315 0 315 255 -2.9 0.1 -2.6 -3.3 10/26/2005 17:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 315 0 315 255 -3.2 0 -3 -3.3 10/26/2005 17:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 354 22 315 255 -3.4 0.1 -3.3 -3.5 10/26/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 255 255 -3.5 0 -3.5 -3.7 10/26/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 8 3 255 255 -3.7 0 -3.5 -3.7 10/26/2005 18:00:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 80 7 81 255 -3.8 0 -3.5 -4.2 10/26/2005 18:10:00 1.6 0.5 2.6 0.7 1.5 0.5 2.6 0.7 0.7 0.4 1.9 0.4 61 12 50 255 -4.2 0 -3.9 -4.4 10/26/2005 18:20:00 1.5 0.3 2.6 0.7 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 76 23 42 255 -4.3 0 -4.4 -4.6 10/26/2005 18:30:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 0.6 0.3 1.5 0.4 75 9 62 255 -4.6 0 -4.4 -4.8 10/26/2005 18:40:00 1.7 0.4 2.3 0.7 1.5 0.4 2.3 0.4 0.6 0.3 1.5 0.4 63 12 58 255 -4.8 0 -4.6 -5 10/26/2005 18:50:00 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.4 1 0.3 1.9 0.4 61 27 85 255 -4.9 0 -4.6 -5 10/26/2005 19:00:00 1.5 0.4 2.6 0.7 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 80 23 93 255 -5.2 0 -5 -5.3 10/26/2005 19:10:00 1.4 0.4 2.3 0.7 1.2 0.5 1.9 0.4 0.6 0.3 1.1 0.4 81 14 53 255 -5.1 0 -4.8 -5.3 10/26/2005 19:20:00 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.4 0.1 1.1 0.4 60 5 56 255 -5.2 0.1 -5 -5.5 10/26/2005 19:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 55 0 55 255 -5.4 0 -5.3 -5.7 10/26/2005 19:40:00 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 83 22 55 255 -5.6 0.1 -5.5 -5.9 10/26/2005 19:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.5 0.4 126 26 87 255 -5.8 0 -5.7 -5.9 10/26/2005 20:00:00 1.6 0.4 2.6 0.7 1.4 0.5 2.3 0.4 0.7 0.5 1.9 0.4 54 21 86 255 -5.9 0 -5.7 -5.9 10/26/2005 20:10:00 1 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 49 21 34 255 -5.8 0 -5.7 -5.9 10/26/2005 20:20:00 1.3 0.5 2.3 0.4 1 0.6 2.3 0.4 0.6 0.3 1.1 0.4 85 13 71 255 -5.7 0 -5.7 -5.7 10/26/2005 20:30:00 1.7 0.3 2.3 1.1 1.6 0.3 2.6 1.1 0.5 0.2 1.5 0.4 51 3 50 255 -5.9 0 -5.7 -6.1 10/26/2005 20:40:00 2.2 0.3 3 1.5 2.2 0.3 3 1.1 1.3 0.4 2.3 0.4 59 10 43 255 -6.1 0 -5.9 -6.1 10/26/2005 20:50:00 1.7 0.3 2.6 0.7 1.6 0.4 2.6 0.4 0.6 0.3 1.5 0.4 64 9 60 255 -6.1 0 -6.1 -6.4 10/26/2005 21:00:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.4 0.2 1.5 0.4 38 11 47 255 -6.1 0 -5.9 -6.1 10/26/2005 21:10:00 1.4 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.2 1.1 0.4 50 22 49 255 -6 0 -5.9 -6.1 10/26/2005 21:20:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 58 16 37 255 -6.2 0 -5.9 -6.4 10/26/2005 21:30:00 1.6 0.2 2.3 1.1 1.3 0.2 1.9 0.7 0.9 0.2 1.1 0.4 77 7 70 255 -6.2 0 -5.9 -6.4 10/26/2005 21:40:00 1.1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 70 8 69 255 -6.2 0 -6.1 -6.4 10/26/2005 21:50:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 79 3 79 255 -6.5 0 -6.1 -6.6 10/26/2005 22:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.8 0.3 1.5 0.4 145 45 196 255 -6.6 0 -6.6 -6.8 10/26/2005 22:10:00 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.4 0.2 1.1 0.4 170 39 94 255 -6.7 0 -6.6 -6.8 10/26/2005 22:20:00 1.9 0.2 2.3 1.5 1.7 0.2 2.3 1.5 0.9 0.3 1.5 0.4 85 6 94 255 -6.7 0 -6.6 -6.8 10/26/2005 22:30:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 0.4 0.2 1.5 0.4 56 7 68 255 -6.8 0 -6.6 -7 10/26/2005 22:40:00 1 0.2 1.9 0.4 0.7 0.3 1.5 0.4 0.8 0.6 2.3 0.4 90 36 95 255 -7.1 0 -6.8 -7 10/26/2005 22:50:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 80 8 101 255 -7.1 0 -6.8 -7 10/26/2005 23:00:00 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 100 17 116 255 -7.1 0 -7 -7 10/26/2005 23:10:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 71 36 116 255 -7.1 0 -7 -7.2 10/26/2005 23:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 98 45 109 255 -7.1 0 -7 -7.2 10/26/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 137 0 255 255 -7.2 0.1 -7 -7.4 10/26/2005 23:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 137 0 137 255 -7.3 0 -7.2 -7.4 10/26/2005 23:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 47 338 255 -7.5 0.1 -7.2 -7.6 10/27/2005 00:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 264 102 339 255 -7.6 0 -7.4 -7.6 10/27/2005 00:10:00 0.4 0.2 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 121 0 122 255 -7.5 0 -7.2 -7.6 10/27/2005 00:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 122 3 131 255 -7.5 0 -7.2 -7.6 10/27/2005 00:30:00 1.4 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.7 0.5 1.9 0.4 120 12 126 255 -7.7 0 -7.6 -7.9 10/27/2005 00:40:00 1.3 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1.2 0.3 1.9 0.4 111 4 118 255 -7.7 0 -7.6 -7.9 10/27/2005 00:50:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 0.5 1.9 0.4 100 7 106 255 -7.7 0 -7.6 -7.9 10/27/2005 01:00:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 100 5 104 255 -7.8 0 -7.6 -7.9 10/27/2005 01:10:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.4 0.1 0.7 0.4 106 5 124 255 -7.7 0 -7.6 -7.9 10/27/2005 01:20:00 1.6 0.5 2.6 0.7 1.4 0.5 2.6 0.4 0.7 0.4 1.9 0.4 116 5 115 255 -7.7 0 -7.6 -7.9 10/27/2005 01:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 127 4 117 255 -7.6 0 -7.4 -7.6 10/27/2005 01:40:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.4 1.9 0.4 130 15 133 255 -7.6 0 -7.6 -7.6 10/27/2005 01:50:00 0.7 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 93 13 97 255 -7.9 0 -7.6 -7.9 10/27/2005 02:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 54 0 54 255 -7.9 0 -7.6 -8.1 10/27/2005 02:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 54 0 54 255 -8 0 -7.9 -8.1 10/27/2005 02:20:00 1.1 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.4 0 0.4 0.4 54 0 55 255 -8.2 0 -8.1 -8.1 10/27/2005 02:30:00 0.9 0.2 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 54 0 55 255 -8.2 0 -8.1 -8.3 10/27/2005 02:40:00 1.2 0.4 2.3 0.4 1.2 0.5 1.9 0.4 0.7 0.3 1.1 0.4 69 14 83 255 -8.2 0 -8.1 -8.3 10/27/2005 02:50:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 0.8 0.3 1.5 0.4 84 2 83 255 -8.2 0 -8.1 -8.3 10/27/2005 03:00:00 2.2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1 0.3 1.9 0.4 80 5 84 255 -8.2 0 -8.1 -8.3 10/27/2005 03:10:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 0.5 0.2 1.1 0.4 66 5 72 255 -8.4 0 -8.3 -8.5 10/27/2005 03:20:00 1.4 0.4 2.3 0.7 1.4 0.4 2.3 0.4 0.9 0.4 1.5 0.4 79 8 86 255 -8.4 0 -8.3 -8.5 10/27/2005 03:30:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.7 0.8 0.3 1.5 0.4 71 2 71 255 -8.3 0 -8.1 -8.5 10/27/2005 03:40:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.4 0.5 0.2 1.1 0.4 54 11 71 255 -8.4 0 -8.3 -8.5 10/27/2005 03:50:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 0.4 0 0.4 0.4 47 0 47 255 -8.5 0 -8.5 -8.7 10/27/2005 04:00:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.5 0.5 0.2 1.1 0.4 39 2 38 255 -8.5 0 -8.5 -8.5 10/27/2005 04:10:00 1.7 0.3 2.3 1.1 1.6 0.2 2.3 1.1 0.9 0.4 1.5 0.4 43 9 38 255 -8.4 0 -8.3 -8.5 10/27/2005 04:20:00 1.4 0.3 2.3 0.7 1.3 0.3 2.3 0.7 0.6 0.2 1.1 0.4 65 7 59 255 -8.3 0 -8.1 -8.3 10/27/2005 04:30:00 1.7 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1 0.4 2.3 0.4 63 5 58 255 -8.3 0 -8.1 -8.5 10/27/2005 04:40:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 1.2 0.6 2.3 0.4 42 12 48 255 -8.6 0.1 -8.5 -8.7 10/27/2005 04:50:00 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.6 0.3 1.5 0.4 58 11 77 255 -8.5 0 -8.5 -8.7 10/27/2005 05:00:00 1.7 0.3 2.6 0.7 1.7 0.3 2.6 0.7 1 0.3 2.3 0.4 73 9 68 255 -8.5 0 -8.5 -8.5 10/27/2005 05:10:00 2.1 0.5 3 1.1 2.1 0.4 3 1.1 1.1 0.3 1.9 0.4 70 12 82 255 -8.5 0 -8.5 -8.5 10/27/2005 05:20:00 2.7 0.4 3.8 1.9 2.7 0.4 3.4 1.5 1.5 0.5 3 0.4 85 9 92 255 -8.5 0 -8.5 -8.7 10/27/2005 05:30:00 2.1 0.3 3 1.5 2 0.3 3 1.1 1.2 0.4 2.3 0.4 81 10 80 255 -8.6 0 -8.5 -8.7 10/27/2005 05:40:00 1.5 0.4 2.3 0.7 1.3 0.4 1.9 0.4 0.7 0.4 1.5 0.4 90 8 85 255 -8.6 0 -8.5 -8.7 10/27/2005 05:50:00 1.4 0.3 2.3 0.4 1.3 0.4 1.9 0.4 0.4 0.1 1.1 0.4 90 6 79 255 -8.6 0 -8.5 -8.7 10/27/2005 06:00:00 1.2 0.3 2.3 0.4 1.1 0.4 2.3 0.4 0.4 0.1 0.7 0.4 95 7 93 255 -8.5 0 -8.5 -8.5 10/27/2005 06:10:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 87 13 100 255 -8.5 0 -8.3 -8.7 10/27/2005 06:20:00 1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.8 0.4 1.9 0.4 114 11 121 255 -8.3 0 -8.1 -8.5 10/27/2005 06:30:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.4 0.7 0.3 1.5 0.4 126 5 127 255 -8.2 0 -8.1 -8.3 10/27/2005 06:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 69 16 101 255 -8.2 0 -8.1 -8.3 10/27/2005 06:50:00 0.9 0.2 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 61 11 77 255 -8.2 0 -8.1 -8.1 10/27/2005 07:00:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 54 255 -8.2 0 -8.1 -8.1 10/27/2005 07:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 53 255 -8.2 0 -8.1 -8.1 10/27/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 255 255 -8.2 0 -8.1 -8.3 10/27/2005 07:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 42 36 53 255 -8.2 0 -8.1 -8.3 10/27/2005 07:40:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.5 0.3 1.1 0.4 258 29 286 255 -8.3 0 -8.1 -8.5 10/27/2005 07:50:00 0.4 0.1 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 220 12 243 255 -8.2 0 -8.1 -8.3 10/27/2005 08:00:00 0.8 0.2 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 243 0 243 255 -8.1 0 -7.9 -8.3 10/27/2005 08:10:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 242 0 243 255 -7.7 0 -7.6 -7.9 10/27/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 0 255 255 -7.5 0 -7.2 -7.6 10/27/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 0 255 255 -7.3 0 -7 -7.4 10/27/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 0 255 255 -7.1 0 -7 -7.2 10/27/2005 08:50:00 0.8 0.6 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 149 66 109 255 -7 0 -6.8 -7 10/27/2005 09:00:00 1.4 0.4 1.9 0.7 1.2 0.4 1.9 0.4 0.4 0.1 0.7 0.4 109 0 109 255 -6.6 0.1 -6.4 -6.8 10/27/2005 09:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 109 0 109 255 -6.2 0.1 -5.9 -6.6 10/27/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 -5.4 0.3 -4.6 -5.9 10/27/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 109 0 255 255 -4.3 0.2 -3.9 -4.8 10/27/2005 09:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 108 6 109 255 -3.9 0 -3.7 -4.2 10/27/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 255 255 -3.7 0 -3.5 -3.7 10/27/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 255 255 -3.3 0 -3 -3.5 10/27/2005 10:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 4 0 3 255 -2.8 0 -2.6 -3.3 10/27/2005 10:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 4 0 4 255 -3 0.1 -2.8 -3.3 10/27/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 4 0 3 255 -2.9 0.1 -2.6 -3.3 10/27/2005 10:40:00 0.5 0.3 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 18 19 49 255 -2.6 0 -2.4 -2.6 10/27/2005 10:50:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 9 26 358 255 -2.4 0 -2.1 -2.6 10/27/2005 11:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 7 13 358 255 -2.1 0 -1.9 -2.4 10/27/2005 11:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 355 32 326 255 -2 0 -1.9 -2.1 10/27/2005 11:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.9 0.4 10 12 14 255 -1.7 0 -1.4 -1.9 10/27/2005 11:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 15 0 15 255 -1.7 0 -1.4 -1.9 10/27/2005 11:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 357 29 15 255 -1.6 0 -1.4 -1.9 10/27/2005 11:50:00 0.8 0.4 1.9 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 302 24 291 255 -1.5 0 -1.2 -1.4 10/27/2005 12:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 329 28 309 255 -1.2 0.1 -0.7 -1.4 10/27/2005 12:10:00 2 0.5 3.4 0.4 1.9 0.5 3 0.4 1.8 0.6 3 0.4 305 12 299 255 -0.6 0.2 -0.1 -1 10/27/2005 12:20:00 2.7 0.3 3.8 1.9 2.5 0.4 3.4 1.5 2.2 0.5 3.4 1.1 307 8 307 255 -0.4 0 -0.1 -0.5 10/27/2005 12:30:00 2.3 0.6 3.4 0.7 2.1 0.6 3 0.4 1.8 0.8 3.4 0.4 317 15 311 255 -0.9 0.1 -0.5 -1.2 10/27/2005 12:40:00 1.9 0.7 3 0.4 1.8 0.6 3 0.4 1.6 0.6 3 0.4 312 15 296 255 -1.2 0 -1 -1.4 10/27/2005 12:50:00 1.7 0.5 3.4 0.4 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 305 16 277 255 -1.3 0 -1.2 -1.4 10/27/2005 13:00:00 2.2 0.3 3 1.1 2 0.4 3 1.1 1.6 0.5 2.6 0.4 312 12 302 255 -1.3 0 -1.2 -1.4 10/27/2005 13:10:00 1.1 0.5 2.6 0.4 1.1 0.6 2.3 0.4 1 0.5 2.3 0.4 303 16 326 255 -1.3 0 -1 -1.4 10/27/2005 13:20:00 1.1 0.6 2.3 0.4 1.1 0.6 2.6 0.4 1.1 0.5 2.3 0.4 298 17 288 255 -0.9 0.1 -0.7 -1.2 10/27/2005 13:30:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 302 13 289 255 -0.8 0 -0.7 -0.7 10/27/2005 13:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0.7 0.3 1.5 0.4 314 15 275 255 -0.7 0 -0.5 -0.7 10/27/2005 13:50:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 310 10 315 255 -0.9 0 -0.7 -1 10/27/2005 14:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.9 0.4 310 18 310 255 -1 0 -0.7 -1 10/27/2005 14:10:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 295 17 295 255 -1 0 -0.7 -1 10/27/2005 14:20:00 1.3 0.5 2.6 0.4 1 0.5 2.6 0.4 1 0.5 2.3 0.4 298 14 314 255 -1 0 -0.7 -1.2 10/27/2005 14:30:00 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1.3 0.7 2.6 0.4 293 12 301 255 -1 0 -0.7 -1.2 10/27/2005 14:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 295 35 262 255 -1 0 -0.7 -1 10/27/2005 14:50:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.5 2.3 0.4 296 17 262 255 -1 0 -0.7 -1.2 10/27/2005 15:00:00 0.4 0.1 1.1 0.4 0.4 0 1.1 0.4 0.4 0.1 1.1 0.4 293 38 315 255 -0.9 0 -0.7 -1 10/27/2005 15:10:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 269 41 309 255 -0.9 0 -0.7 -1 10/27/2005 15:20:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 284 30 246 255 -0.9 0 -0.7 -1 10/27/2005 15:30:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 307 20 350 255 -0.9 0 -0.7 -1 10/27/2005 15:40:00 1.1 0.6 2.6 0.4 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 309 15 318 255 -1 0 -1 -1.2 10/27/2005 15:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 311 9 315 255 -1.2 0 -1.2 -1.4 10/27/2005 16:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 306 5 317 255 -1.3 0 -1.2 -1.4 10/27/2005 16:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 311 0 311 255 -1.5 0 -1.2 -1.4 10/27/2005 16:20:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 311 0 311 255 -1.6 0 -1.4 -1.7 10/27/2005 16:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 305 15 311 255 -1.7 0 -1.4 -1.9 10/27/2005 16:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 271 7 269 255 -1.9 0 -1.7 -1.9 10/27/2005 16:50:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 292 9 299 255 -2 0 -1.9 -2.1 10/27/2005 17:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 300 3 300 255 -2.1 0 -1.9 -2.1 10/27/2005 17:10:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 313 10 314 255 -2.2 0 -2.1 -2.4 10/27/2005 17:20:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.3 1.9 0.4 296 9 300 255 -2.4 0 -2.1 -2.6 10/27/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 0 255 255 -2.4 0 -2.1 -2.6 10/27/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 340 26 255 255 -2.4 0 -2.1 -2.6 10/27/2005 17:50:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 3 8 358 255 -2.5 0 -2.4 -2.6 10/27/2005 18:00:00 1 0.2 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 17 0 17 255 -2.6 0 -2.6 -2.6 10/27/2005 18:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 22 8 17 255 -2.6 0 -2.6 -2.6 10/27/2005 18:20:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 42 5 34 255 -2.6 0 -2.6 -2.8 10/27/2005 18:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 47 0 47 255 -2.6 0 -2.6 -2.6 10/27/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 -2.7 0 -2.6 -2.8 10/27/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 -2.8 0 -2.6 -2.8 10/27/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 37 12 255 255 -2.8 0 -2.6 -2.8 10/27/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 255 255 -2.8 0 -2.6 -2.8 10/27/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 255 255 -2.8 0 -2.8 -2.8 10/27/2005 19:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 33 10 47 255 -2.8 0 -2.8 -2.8 10/27/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 -2.9 0 -2.8 -2.8 10/27/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 255 255 -2.9 0 -2.8 -3 10/27/2005 20:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 38 12 46 255 -2.9 0 -2.8 -3 10/27/2005 20:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 40 6 22 255 -3 0 -2.8 -3 10/27/2005 20:20:00 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 65 0 66 255 -3 0 -2.8 -3 10/27/2005 20:30:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 88 16 104 255 -3.1 0 -3 -3.3 10/27/2005 20:40:00 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 85 12 104 255 -3.1 0 -3 -3.3 10/27/2005 20:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 65 6 58 255 -3.1 0 -2.8 -3.3 10/27/2005 21:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 57 0 58 255 -3.1 0 -2.8 -3.3 10/27/2005 21:10:00 0.7 0.6 3.4 0.4 0.7 0.6 3 0.4 0.5 0.3 1.9 0.4 65 9 76 255 -3.1 0 -3 -3.3 10/27/2005 21:20:00 1.5 0.7 3.8 0.4 1.5 0.8 3.8 0.4 0.9 0.5 2.3 0.4 34 21 37 255 -3.1 0 -3 -3.3 10/27/2005 21:30:00 0.8 0.4 1.9 0.4 0.6 0.3 2.3 0.4 0.5 0.2 1.1 0.4 337 20 28 255 -3.2 0 -3 -3.3 10/27/2005 21:40:00 0.9 0.6 2.6 0.4 0.8 0.7 3 0.4 0.7 0.5 2.3 0.4 33 61 64 255 -3.1 0 -2.8 -3.3 10/27/2005 21:50:00 1.1 0.8 3.8 0.4 1.1 0.8 3.4 0.4 0.7 0.6 3 0.4 47 38 85 255 -3 0 -2.8 -3 10/27/2005 22:00:00 2.4 0.9 4.6 0.4 2.4 1 4.6 0.4 1.8 0.8 4.2 0.4 70 16 79 255 -2.8 0.1 -2.4 -3 10/27/2005 22:10:00 2.7 0.8 4.9 1.1 2.7 0.8 4.6 1.1 2 0.8 4.2 0.4 62 16 32 255 -2.1 0 -1.9 -2.6 10/27/2005 22:20:00 2.4 0.6 4.2 0.7 2.3 0.6 4.2 0.7 1.8 0.5 3.8 0.7 53 12 67 255 -2.1 0 -1.9 -2.1 10/27/2005 22:30:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 1 0.4 2.3 0.4 49 12 52 255 -2.3 0 -2.1 -2.6 10/27/2005 22:40:00 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 23 27 40 255 -2.6 0 -2.4 -2.8 10/27/2005 22:50:00 1 0.7 3.4 0.4 1 0.7 3 0.4 0.7 0.6 2.6 0.4 67 24 86 255 -3 0.1 -2.8 -3.3 10/27/2005 23:00:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 71 14 85 255 -2.8 0 -2.6 -3 10/27/2005 23:10:00 0.5 0.4 1.9 0.4 0.5 0.3 2.3 0.4 0.4 0.1 0.7 0.4 43 4 66 255 -3 0 -2.8 -3 10/27/2005 23:20:00 0.8 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.1 0.4 30 15 23 255 -3.1 0 -2.8 -3.3 10/27/2005 23:30:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 333 15 17 255 -3.2 0 -3 -3.3 10/27/2005 23:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 353 17 333 255 -3.2 0 -3 -3.3 10/27/2005 23:50:00 1.5 0.7 3.4 0.4 1.4 0.8 3.4 0.4 0.9 0.7 3.8 0.4 65 27 74 255 -3.1 0 -3 -3.3 10/28/2005 00:00:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 0.7 0.4 1.9 0.4 66 13 80 255 -3.1 0 -2.6 -3.3 10/28/2005 00:10:00 1.4 0.6 3.4 0.4 1.2 0.6 3.4 0.4 0.9 0.6 3 0.4 67 13 66 255 -3.1 0 -2.8 -3.3 10/28/2005 00:20:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 69 15 56 255 -2.8 0 -2.6 -3 10/28/2005 00:30:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 51 11 64 255 -2.8 0 -2.6 -2.8 10/28/2005 00:40:00 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.2 1.1 0.4 46 8 53 255 -2.9 0 -2.8 -3 10/28/2005 00:50:00 1.3 0.5 2.6 0.4 0.9 0.6 2.3 0.4 0.6 0.3 1.9 0.4 35 13 31 255 -3 0 -2.8 -3 10/28/2005 01:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 62 4 50 255 -3 0 -2.8 -3 10/28/2005 01:10:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 50 0 50 255 -3.1 0 -3 -3.3 10/28/2005 01:20:00 1.2 0.5 2.6 0.4 1 0.5 2.6 0.4 0.5 0.4 2.3 0.4 75 16 86 255 -3.1 0 -3 -3.3 10/28/2005 01:30:00 1.7 0.6 3.4 0.7 1.4 0.7 3.4 0.4 0.8 0.5 2.3 0.4 73 10 79 255 -3.1 0 -3 -3.3 10/28/2005 01:40:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 67 15 69 255 -3.2 0 -3.3 -3.3 10/28/2005 01:50:00 1.9 0.4 3 1.1 1.7 0.4 3 0.7 1 0.4 2.6 0.4 59 8 51 255 -3.2 0 -3.3 -3.3 10/28/2005 02:00:00 1.4 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.6 0.3 1.5 0.4 68 12 68 255 -3.2 0 -3.3 -3.3 10/28/2005 02:10:00 2.7 1 4.9 0.4 2.7 1 4.9 0.4 2.2 1 4.6 0.4 95 17 93 255 -3 0.1 -2.6 -3.3 10/28/2005 02:20:00 2.5 0.6 4.6 0.7 2.5 0.6 4.2 0.7 1.9 0.7 3.8 0.4 76 15 83 255 -2.5 0 -2.4 -2.6 10/28/2005 02:30:00 1.8 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.4 0.3 2.3 0.7 55 7 57 255 -2.6 0 -2.4 -2.8 10/28/2005 02:40:00 1.7 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 50 9 68 255 -2.8 0 -2.6 -2.8 10/28/2005 02:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 35 5 35 255 -3.1 0.1 -2.8 -3.3 10/28/2005 03:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 40 0 40 255 -3.4 0.1 -3.3 -3.5 10/28/2005 03:10:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 43 8 255 255 -3.6 0 -3.5 -3.5 10/28/2005 03:20:00 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 60 0 60 255 -3.7 0 -3.5 -3.7 10/28/2005 03:30:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1 0.4 1.9 0.4 53 8 44 255 -3.8 0 -3.5 -3.9 10/28/2005 03:40:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 48 1 48 255 -3.9 0 -3.7 -3.9 10/28/2005 03:50:00 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.1 0.4 58 11 66 255 -4 0.1 -3.9 -4.4 10/28/2005 04:00:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 80 12 86 255 -4.2 0 -3.9 -4.4 10/28/2005 04:10:00 1.9 0.3 2.6 0.7 1.8 0.3 2.3 0.7 1.1 0.4 2.3 0.4 106 6 102 255 -4.1 0 -3.9 -4.2 10/28/2005 04:20:00 1.7 0.4 2.6 1.1 1.5 0.4 2.3 0.4 0.7 0.4 1.9 0.4 104 9 104 255 -4.1 0 -3.9 -4.2 10/28/2005 04:30:00 1.7 0.3 2.3 1.1 1.5 0.3 2.3 0.7 0.8 0.4 1.9 0.4 97 7 101 255 -4 0 -3.9 -4.2 10/28/2005 04:40:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 0.6 0.3 1.5 0.4 89 6 81 255 -4 0 -3.9 -4.2 10/28/2005 04:50:00 1.9 0.5 3.4 0.4 1.8 0.5 3 0.4 1.2 0.4 2.3 0.4 83 13 73 255 -4.1 0 -3.9 -4.2 10/28/2005 05:00:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.9 0.5 2.3 0.4 98 13 85 255 -4.3 0 -4.2 -4.4 10/28/2005 05:10:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.4 1.9 0.4 102 13 93 255 -4.3 0 -4.2 -4.4 10/28/2005 05:20:00 2.3 0.5 3.4 1.1 2.3 0.6 3.4 0.7 1.7 0.5 3 0.4 85 12 84 255 -4 0 -3.9 -4.4 10/28/2005 05:30:00 2.4 0.5 4.2 1.1 2.4 0.6 3.8 1.1 1.6 0.6 3 0.4 92 11 87 255 -3.8 0 -3.5 -3.9 10/28/2005 05:40:00 2.7 0.6 4.2 0.7 2.6 0.7 4.2 0.7 2.1 0.7 4.2 0.4 98 13 70 255 -3.4 0.1 -3.3 -3.7 10/28/2005 05:50:00 2.6 0.6 4.2 1.1 2.5 0.7 4.2 1.1 2 0.7 3.8 0.4 95 13 94 255 -3.2 0 -3 -3.3 10/28/2005 06:00:00 3.2 0.7 4.9 1.1 3.2 0.7 4.9 1.5 2.6 0.6 4.6 1.1 98 12 101 255 -3.1 0 -3 -3.3 10/28/2005 06:10:00 3.2 0.7 4.9 1.5 3.2 0.7 4.6 1.5 2.7 0.8 4.6 0.7 96 14 93 255 -3 0 -3 -3.3 10/28/2005 06:20:00 3.2 0.8 5.7 0.7 3.2 0.8 5.7 0.7 2.7 0.8 5.3 0.4 93 14 99 255 -3 0 -2.8 -3.3 10/28/2005 06:30:00 2.8 0.7 4.6 1.1 2.7 0.6 4.6 1.1 2.3 0.8 4.2 0.4 95 10 88 255 -3 0 -2.8 -3.3 10/28/2005 06:40:00 2.4 0.6 3.8 0.4 2.3 0.7 3.8 0.4 1.6 0.7 3 0.4 87 11 90 255 -3.2 0 -3 -3.5 10/28/2005 06:50:00 1.9 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.3 0.5 3 0.4 80 14 90 255 -3.4 0 -3.3 -3.5 10/28/2005 07:00:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 1.2 0.5 2.6 0.4 86 14 92 255 -3.5 0 -3.5 -3.5 10/28/2005 07:10:00 1.8 0.5 3.4 0.4 1.7 0.6 3.4 0.4 0.9 0.5 2.3 0.4 100 14 94 255 -3.8 0 -3.5 -3.9 10/28/2005 07:20:00 1.7 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1.2 0.6 3 0.4 99 12 96 255 -4 0 -3.9 -4.2 10/28/2005 07:30:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 1.1 0.6 2.6 0.4 104 12 94 255 -4 0 -3.9 -4.2 10/28/2005 07:40:00 1.7 0.5 3 0.4 1.6 0.6 3 0.4 1.1 0.5 2.6 0.4 92 15 96 255 -3.9 0 -3.9 -4.2 10/28/2005 07:50:00 1.8 0.4 3 0.7 1.8 0.4 3 0.7 1.1 0.5 2.3 0.4 89 11 84 255 -4.1 0.1 -3.9 -4.4 10/28/2005 08:00:00 2.1 0.6 3.4 0.7 2 0.5 3.4 0.7 1.5 0.6 3.4 0.4 92 13 89 255 -4.3 0 -4.2 -4.4 10/28/2005 08:10:00 2.3 0.5 3.4 0.7 2.2 0.6 3.4 0.7 1.3 0.6 2.6 0.4 89 13 66 255 -4.3 0 -3.9 -4.4 10/28/2005 08:20:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.5 1.8 0.6 3 0.4 90 7 96 255 -4.3 0 -4.4 -4.4 10/28/2005 08:30:00 1.9 0.5 3 0.7 1.8 0.6 3 0.4 1.1 0.6 2.6 0.4 94 10 97 255 -4.3 0 -4.4 -4.4 10/28/2005 08:40:00 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 100 5 108 255 -4.4 0 -4.4 -4.6 10/28/2005 08:50:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 65 16 79 255 -4.7 0.1 -4.4 -4.8 10/28/2005 09:00:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 64 9 58 255 -4.7 0.1 -4.4 -4.8 10/28/2005 09:10:00 1.5 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.8 0.4 1.9 0.4 85 8 90 255 -4.3 0 -4.2 -4.6 10/28/2005 09:20:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 78 7 77 255 -3.9 0.1 -3.5 -4.2 10/28/2005 09:30:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 72 12 76 255 -3.4 0 -3.3 -3.5 10/28/2005 09:40:00 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 38 11 21 255 -3.4 0 -3.3 -3.5 10/28/2005 09:50:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 81 8 76 255 -3.4 0 -3.3 -3.5 10/28/2005 10:00:00 1.1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.6 0.4 1.5 0.4 82 11 71 255 -3.1 0 -2.8 -3.3 10/28/2005 10:10:00 0.8 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.4 1.9 0.4 67 14 76 255 -2.8 0 -2.6 -2.8 10/28/2005 10:20:00 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 60 11 58 255 -2.5 0 -2.1 -2.6 10/28/2005 10:30:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 62 17 76 255 -2.2 0 -2.1 -2.4 10/28/2005 10:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 56 15 30 255 -2.1 0 -1.9 -2.1 10/28/2005 10:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 72 15 56 255 -2 0 -1.9 -2.1 10/28/2005 11:00:00 1.2 0.3 1.9 0.7 0.8 0.4 1.9 0.4 0.9 0.3 1.9 0.4 31 9 20 255 -1.8 0 -1.7 -1.9 10/28/2005 11:10:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 31 0 31 255 -1.9 0 -1.9 -1.9 10/28/2005 11:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 31 0 31 255 -1.7 0 -1.7 -1.9 10/28/2005 11:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 31 255 -1.7 0 -1.4 -1.9 10/28/2005 11:40:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 28 8 31 255 -1.4 0.1 -1.2 -1.7 10/28/2005 11:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 356 12 358 255 -1 0.1 -0.7 -1.4 10/28/2005 12:00:00 1.4 0.3 1.9 0.4 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 6 8 358 255 -1 0 -0.7 -1.2 10/28/2005 12:10:00 1.1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 9 15 354 255 -1 0 -1 -1.2 10/28/2005 12:20:00 1.3 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.9 0.4 1.5 0.4 354 7 352 255 -1 0 -0.7 -1 10/28/2005 12:30:00 0.9 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.1 0.4 15 13 354 255 -1 0 -0.7 -1.2 10/28/2005 12:40:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 17 28 22 255 -1 0 -1 -1.2 10/28/2005 12:50:00 1.1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.9 0.4 7 20 327 255 -1 0 -1 -1.2 10/28/2005 13:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 355 11 2 255 -0.9 0 -0.7 -1 10/28/2005 13:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 352 11 339 255 -0.7 0 -0.5 -0.7 10/28/2005 13:20:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 338 15 328 255 -0.5 0 -0.5 -0.5 10/28/2005 13:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 356 36 319 255 -0.4 0 -0.1 -0.5 10/28/2005 13:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 14 30 349 255 -0.3 0 -0.1 -0.5 10/28/2005 13:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 25 11 28 255 -0.3 0 -0.1 -0.5 10/28/2005 14:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 27 6 28 255 -0.3 0 -0.1 -0.5 10/28/2005 14:10:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 4 0 255 -0.2 0 -0.1 -0.3 10/28/2005 14:20:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 4 14 356 255 -0.2 0 -0.1 -0.3 10/28/2005 14:30:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 347 2 347 255 -0.2 0 -0.1 -0.3 10/28/2005 14:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 318 0 318 255 -0.3 0 -0.1 -0.5 10/28/2005 14:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 325 11 322 255 -0.3 0 -0.1 -0.5 10/28/2005 15:00:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 295 26 315 255 -0.3 0 -0.1 -0.5 10/28/2005 15:10:00 1.3 0.4 2.3 0.4 1.1 0.5 1.9 0.4 1.1 0.5 2.3 0.4 292 11 286 255 -0.6 0 -0.5 -0.7 10/28/2005 15:20:00 1.7 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.6 0.4 2.3 0.4 299 6 296 255 -0.7 0 -0.5 -0.7 10/28/2005 15:30:00 1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 0.8 0.6 2.3 0.4 282 17 293 255 -0.9 0 -0.7 -0.7 10/28/2005 15:40:00 1.3 0.6 3 0.4 1.2 0.6 3 0.4 0.9 0.6 2.6 0.4 273 13 264 255 -0.7 0 -0.7 -0.7 10/28/2005 15:50:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 281 24 289 255 -0.9 0 -0.7 -1.2 10/28/2005 16:00:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 292 22 306 255 -1.1 0 -1 -1.2 10/28/2005 16:10:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 308 10 315 255 -1.2 0 -1 -1.2 10/28/2005 16:20:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 306 12 306 255 -1.3 0 -1.2 -1.4 10/28/2005 16:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 296 11 292 255 -1.4 0 -1.2 -1.4 10/28/2005 16:40:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 308 3 313 255 -1.5 0 -1.4 -1.4 10/28/2005 16:50:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 318 13 304 255 -1.6 0 -1.4 -1.7 10/28/2005 17:00:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 304 13 338 255 -1.7 0 -1.4 -1.9 10/28/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 299 0 255 255 -1.9 0 -1.7 -2.1 10/28/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.1 0 -1.9 -2.1 10/28/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.4 0 -2.1 -2.6 10/28/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.6 0 -2.6 -2.6 10/28/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.6 0 -2.6 -2.8 10/28/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.6 0 -2.6 -2.6 10/28/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.8 0 -2.6 -2.8 10/28/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.8 0 -2.6 -3 10/28/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.9 0 -2.8 -3 10/28/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -2.9 0 -2.8 -3 10/28/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -3 0 -2.8 -3 10/28/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -3 0 -2.8 -3.3 10/28/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 255 255 -3.1 0 -2.8 -3.3 10/28/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 45 255 255 -3.2 0 -3.3 -3.3 10/28/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 255 255 -3.3 0 -3.3 -3.5 10/28/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 255 255 -3.4 0 -3.3 -3.5 10/28/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 255 255 -3.5 0 -3.3 -3.5 10/28/2005 20:00:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 63 255 -3.7 0 -3.5 -3.7 10/28/2005 20:10:00 1.2 0.3 1.9 0.7 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 64 2 63 255 -3.9 0 -3.7 -4.2 10/28/2005 20:20:00 1.1 0.2 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 77 4 64 255 -4.2 0 -3.9 -4.4 10/28/2005 20:30:00 1.1 0.2 1.5 0.7 0.8 0.2 1.1 0.4 0.4 0.2 1.1 0.4 84 7 78 255 -4.3 0 -4.2 -4.4 10/28/2005 20:40:00 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 100 1 92 255 -4.7 0.1 -4.4 -4.8 10/28/2005 20:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 105 12 134 255 -5 0 -4.8 -5.3 10/28/2005 21:00:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.2 1.5 0.4 135 0 134 255 -5.3 0 -5 -5.5 10/28/2005 21:10:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.7 0.3 1.5 0.4 127 8 121 255 -5.5 0 -5.5 -5.7 10/28/2005 21:20:00 2 0.6 3 0.4 1.9 0.6 2.6 0.4 1.1 0.5 2.3 0.4 108 8 105 255 -5.9 0 -5.5 -5.9 10/28/2005 21:30:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 1.7 0.4 2.6 0.7 103 5 99 255 -6.1 0 -5.9 -6.1 10/28/2005 21:40:00 2.7 0.4 3.8 1.9 2.6 0.4 3.8 1.5 1.4 0.5 2.6 0.4 109 8 96 255 -6.1 0 -6.1 -6.1 10/28/2005 21:50:00 2.8 0.4 3.8 1.5 2.7 0.5 3.8 1.5 1.6 0.5 3 0.7 110 9 109 255 -5.9 0 -5.7 -6.1 10/28/2005 22:00:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.7 0.5 3 0.4 111 10 121 255 -5.5 0.1 -5.5 -5.7 10/28/2005 22:10:00 3.2 0.5 4.6 1.5 3.2 0.5 4.2 1.9 2.2 0.7 3.8 0.7 106 11 108 255 -5.1 0.2 -4.8 -5.5 10/28/2005 22:20:00 3.4 0.7 4.9 1.9 3.3 0.7 5.3 1.9 2.6 0.7 4.6 0.7 108 11 105 255 -4.3 0.2 -3.9 -4.8 10/28/2005 22:30:00 3 0.6 4.9 1.5 2.9 0.7 4.6 1.1 2.2 0.6 3.8 0.7 109 12 85 255 -3.8 0 -3.7 -3.9 10/28/2005 22:40:00 2.5 0.7 4.2 0.7 2.5 0.7 4.2 0.7 2 0.7 4.2 0.4 109 15 103 255 -3.7 0 -3.5 -3.7 10/28/2005 22:50:00 2.4 0.6 4.2 0.7 2.4 0.6 3.8 0.4 1.9 0.7 3.8 0.4 101 13 92 255 -3.7 0 -3.5 -3.7 10/28/2005 23:00:00 3.1 0.8 5.3 1.1 3 0.8 4.9 1.1 2.3 0.8 4.6 0.4 101 13 94 255 -3.7 0 -3.5 -3.7 10/28/2005 23:10:00 3.2 0.7 5.3 1.1 3.2 0.8 5.7 0.7 2.7 0.8 4.6 0.7 102 13 77 255 -3.5 0 -3.3 -3.5 10/28/2005 23:20:00 2.8 0.7 4.6 0.7 2.7 0.8 4.6 0.4 2.1 0.8 3.8 0.4 102 13 92 255 -3.3 0 -3.3 -3.5 10/28/2005 23:30:00 3.1 0.8 4.9 0.7 3.1 0.8 4.6 0.4 2.6 0.8 4.2 0.4 102 13 111 255 -3.3 0 -3.3 -3.5 10/28/2005 23:40:00 3.1 0.8 4.9 1.5 3.1 0.7 4.9 1.5 2.4 0.9 4.6 0.4 102 12 92 255 -3.4 0 -3.3 -3.5 10/28/2005 23:50:00 2.8 0.7 4.6 1.5 2.8 0.6 4.6 1.1 2.2 0.7 4.2 0.7 96 14 79 255 -3.5 0 -3.3 -3.5 10/29/2005 00:00:00 2.8 0.7 4.6 1.1 2.8 0.7 4.2 0.7 2.4 0.7 4.2 0.4 104 12 105 255 -3.5 0 -3.3 -3.5 10/29/2005 00:10:00 3.1 0.8 4.6 1.1 3.1 0.8 4.9 1.1 2.5 0.7 4.2 0.7 102 13 94 255 -3.5 0 -3.3 -3.5 10/29/2005 00:20:00 3.3 0.6 4.6 1.5 3.3 0.6 4.6 1.5 2.8 0.7 4.2 0.7 107 13 121 255 -3.5 0 -3.5 -3.7 10/29/2005 00:30:00 3.6 0.7 5.7 1.9 3.6 0.7 5.3 1.9 2.8 0.8 4.6 1.1 108 12 113 255 -3.7 0 -3.5 -3.9 10/29/2005 00:40:00 3.6 0.7 5.3 1.1 3.6 0.7 5.3 0.7 3 0.6 4.6 0.7 106 13 90 255 -3.8 0 -3.7 -3.9 10/29/2005 00:50:00 3.7 0.7 5.7 1.5 3.7 0.7 5.3 1.9 2.8 0.8 4.9 0.7 110 13 117 255 -4.1 0 -3.9 -4.2 10/29/2005 01:00:00 3.6 0.8 5.3 1.5 3.6 0.8 5.3 1.5 2.7 0.9 5.3 1.1 113 13 102 255 -4.3 0 -3.9 -4.4 10/29/2005 01:10:00 3.8 0.7 5.7 1.1 3.8 0.7 5.3 1.5 2.9 0.9 5.3 0.4 111 15 102 255 -4.3 0 -4.4 -4.4 10/29/2005 01:20:00 3.4 0.7 5.3 1.5 3.4 0.7 5.3 1.5 2.7 0.8 4.9 0.7 108 15 99 255 -4.5 0 -4.4 -4.6 10/29/2005 01:30:00 3.8 0.8 5.7 1.9 3.8 0.8 5.7 1.5 2.9 0.9 4.9 0.7 109 11 112 255 -4.5 0 -4.4 -4.6 10/29/2005 01:40:00 3.8 0.7 5.7 2.3 3.8 0.7 6.1 1.9 3.1 0.7 4.6 0.7 106 12 108 255 -4.7 0 -4.6 -4.8 10/29/2005 01:50:00 3.4 0.8 4.9 1.1 3.4 0.8 4.9 1.5 2.6 0.8 4.6 0.7 108 13 112 255 -4.8 0 -4.6 -4.8 10/29/2005 02:00:00 3.6 0.7 4.9 1.5 3.6 0.7 5.3 1.5 2.8 0.8 4.9 1.1 106 11 99 255 -4.9 0 -4.6 -4.8 10/29/2005 02:10:00 3.8 0.7 5.7 1.9 3.8 0.8 5.7 1.9 3.1 0.8 4.9 1.1 109 11 97 255 -4.7 0 -4.6 -4.8 10/29/2005 02:20:00 3.7 0.7 5.3 1.1 3.7 0.7 5.3 1.5 2.9 0.9 5.3 0.7 110 13 103 255 -4.5 0 -4.4 -4.6 10/29/2005 02:30:00 3 0.7 4.6 1.1 3 0.8 4.6 0.7 2.3 0.7 3.8 0.4 114 14 115 255 -4.6 0 -4.4 -4.6 10/29/2005 02:40:00 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.4 0.7 4.2 0.7 113 13 113 255 -4.8 0 -4.6 -4.8 10/29/2005 02:50:00 3.3 0.7 4.9 1.1 3.2 0.7 4.9 1.1 2.5 0.6 4.2 1.1 113 14 99 255 -4.9 0 -4.8 -5 10/29/2005 03:00:00 3.9 0.8 6.1 1.1 3.9 0.8 6.1 1.9 3.1 0.8 5.3 0.7 113 13 112 255 -4.9 0 -4.6 -5 10/29/2005 03:10:00 4.2 0.9 6.1 1.9 4.3 0.8 6.1 2.3 3.6 0.8 5.3 1.5 112 13 105 255 -4.8 0 -4.6 -4.8 10/29/2005 03:20:00 4.1 0.8 6.1 1.9 4 0.8 6.1 1.9 3.3 0.8 5.3 1.5 108 14 108 255 -4.6 0 -4.4 -4.6 10/29/2005 03:30:00 4.2 1 6.5 2.3 4.2 1 6.8 1.9 3.6 1 6.8 1.9 107 13 110 255 -4.6 0 -4.6 -4.6 10/29/2005 03:40:00 4.5 1 6.5 2.3 4.5 0.9 6.8 2.3 3.8 1 6.1 1.1 110 13 119 255 -4.6 0 -4.4 -4.6 10/29/2005 03:50:00 4.2 0.9 6.5 1.9 4.2 0.9 6.5 1.9 3.4 0.8 5.3 1.9 108 15 118 255 -4.6 0 -4.4 -4.6 10/29/2005 04:00:00 4.2 0.8 6.5 2.3 4.2 0.8 6.1 1.9 3.4 0.8 5.7 1.5 108 13 98 255 -4.7 0 -4.6 -4.6 10/29/2005 04:10:00 4.4 0.8 6.5 2.3 4.4 0.8 6.8 2.3 3.4 1.1 6.1 1.1 103 14 109 255 -4.6 0 -4.6 -4.6 10/29/2005 04:20:00 4.9 0.8 6.8 2.6 4.9 0.9 7.2 3 4 0.9 6.5 1.9 107 13 119 255 -4.7 0 -4.6 -4.6 10/29/2005 04:30:00 4.8 1 7.6 2.6 4.8 1 8 2.6 4.1 1 7.2 2.3 102 13 87 255 -4.7 0 -4.6 -4.8 10/29/2005 04:40:00 4.7 1 7.2 1.9 4.7 1 7.6 2.3 3.9 1 6.5 1.9 105 15 90 255 -4.8 0 -4.6 -4.8 10/29/2005 04:50:00 5.1 1.2 8 1.5 5 1.2 7.6 1.5 4.2 1.2 8 1.1 103 15 109 255 -4.9 0 -4.8 -5 10/29/2005 05:00:00 4.4 1.3 8 1.1 4.4 1.2 8 1.5 3.5 1.2 6.8 1.1 102 15 74 255 -5 0 -4.8 -5 10/29/2005 05:10:00 5.3 0.9 7.6 3 5.2 0.9 8 3 4.4 0.9 6.5 1.1 99 11 94 255 -5 0 -4.8 -5 10/29/2005 05:20:00 4.6 1 6.8 1.5 4.6 1 6.8 2.3 3.6 1.1 6.5 1.5 99 13 98 255 -5 0 -4.8 -5 10/29/2005 05:30:00 4.3 1 6.5 1.5 4.3 1 6.1 1.9 3.5 1.1 5.7 0.7 99 13 112 255 -5.2 0 -5 -5.3 10/29/2005 05:40:00 4 0.8 5.7 1.5 4 0.7 6.1 1.9 3.2 0.8 5.7 1.5 100 15 109 255 -5.4 0 -5.3 -5.5 10/29/2005 05:50:00 4.3 1.1 6.8 1.9 4.4 1.1 7.2 1.9 3.6 1.2 6.5 0.7 101 16 102 255 -5.5 0 -5.5 -5.5 10/29/2005 06:00:00 4.2 0.8 6.5 2.3 4.3 0.8 6.8 2.6 3.5 0.9 5.7 1.5 102 14 102 255 -5.5 0 -5.5 -5.7 10/29/2005 06:10:00 4.4 1 7.2 1.9 4.4 1 6.8 1.9 3.5 1.1 6.5 1.1 99 15 124 255 -5.6 0 -5.5 -5.7 10/29/2005 06:20:00 4.3 0.8 6.8 2.6 4.3 0.8 6.8 1.9 3.5 1 6.1 1.1 98 13 98 255 -5.6 0 -5.5 -5.7 10/29/2005 06:30:00 4.2 0.9 6.1 1.1 4.2 0.8 6.1 1.9 3.5 0.9 5.7 1.5 97 16 112 255 -5.7 0 -5.5 -5.7 10/29/2005 06:40:00 4.4 0.8 6.8 2.6 4.4 0.8 6.8 2.3 3.7 0.8 6.5 1.9 98 13 98 255 -5.8 0.1 -5.7 -5.9 10/29/2005 06:50:00 4.3 0.8 6.5 1.9 4.2 0.8 6.1 1.9 3.6 0.8 5.7 1.5 103 12 88 255 -5.9 0 -5.7 -5.9 10/29/2005 07:00:00 4.5 0.9 6.8 1.9 4.5 1 6.8 1.5 3.7 1 6.5 1.5 108 14 99 255 -6 0 -5.7 -5.9 10/29/2005 07:10:00 4.9 0.9 7.2 2.3 4.8 0.9 6.8 2.3 4 1.1 6.5 1.1 110 14 115 255 -6 0 -5.7 -5.9 10/29/2005 07:20:00 4.7 1 7.2 2.3 4.7 0.9 6.8 2.3 3.8 0.9 6.1 0.7 104 13 93 255 -6 0 -5.9 -6.1 10/29/2005 07:30:00 4.1 0.8 6.5 2.3 4.2 0.8 6.5 2.3 3.4 1 6.1 0.7 103 13 106 255 -6.1 0 -5.9 -6.1 10/29/2005 07:40:00 4.1 0.9 6.1 0.4 4.1 0.9 6.1 0.7 3.1 0.9 4.9 0.4 102 13 93 255 -6.1 0 -6.1 -6.1 10/29/2005 07:50:00 4 0.8 6.1 1.9 4 0.8 5.7 1.5 3.1 0.9 5.7 1.1 99 12 98 255 -6.3 0 -6.1 -6.4 10/29/2005 08:00:00 3.7 0.8 5.7 1.5 3.7 0.8 5.7 1.5 2.9 0.9 5.3 0.7 97 13 86 255 -6.4 0 -6.1 -6.4 10/29/2005 08:10:00 3.9 1 6.8 1.5 3.9 1 6.5 1.5 3.1 1.1 5.7 0.7 96 15 99 255 -6.2 0 -6.1 -6.4 10/29/2005 08:20:00 3.9 1 6.8 1.5 4 1 6.5 1.9 3.3 1 6.1 1.1 97 15 101 255 -6.1 0 -5.9 -6.1 10/29/2005 08:30:00 4.5 0.8 6.5 1.9 4.5 0.8 6.5 2.3 3.6 1 5.7 1.1 103 12 124 255 -6.1 0 -5.9 -6.1 10/29/2005 08:40:00 4.4 0.9 6.8 2.3 4.4 0.9 6.5 1.5 3.6 0.8 5.7 1.5 104 12 101 255 -6.1 0 -5.9 -6.1 10/29/2005 08:50:00 4.3 0.7 5.7 2.6 4.3 0.7 6.1 2.6 3.6 0.8 5.7 1.9 106 11 118 255 -6.1 0 -5.9 -6.1 10/29/2005 09:00:00 4.3 1 6.8 1.9 4.3 0.9 6.5 2.3 3.5 1 5.3 1.5 103 13 110 255 -5.9 0 -5.7 -5.9 10/29/2005 09:10:00 4.5 1.1 7.2 1.5 4.5 1.1 6.8 1.9 3.8 1.2 6.8 1.5 100 11 101 255 -6 0 -5.7 -5.9 10/29/2005 09:20:00 4.6 1 6.8 1.9 4.6 1 7.2 1.9 3.9 0.9 6.5 1.9 103 11 96 255 -5.9 0 -5.7 -5.9 10/29/2005 09:30:00 4 1 6.1 1.5 4 1 6.1 1.9 3.5 1 5.3 1.1 100 12 105 255 -5.7 0 -5.7 -5.7 10/29/2005 09:40:00 3.7 1.1 6.5 1.1 3.7 1 6.5 1.5 2.8 1 5.7 0.7 103 15 102 255 -5.6 0 -5.5 -5.7 10/29/2005 09:50:00 3.9 0.8 6.1 1.9 3.9 0.8 6.1 1.9 3.2 0.9 6.1 1.1 101 13 108 255 -5.4 0 -5.5 -5.7 10/29/2005 10:00:00 4.5 1 6.8 1.5 4.4 1 6.8 1.1 3.8 1.1 6.1 0.7 99 13 106 255 -5.2 0 -4.8 -5.5 10/29/2005 10:10:00 4.2 1 6.5 2.3 4.1 1 6.5 1.1 3.5 1 6.1 1.5 98 13 93 255 -4.7 0.1 -4.4 -5 10/29/2005 10:20:00 3.9 0.7 5.7 1.9 3.8 0.7 5.3 2.3 3.5 0.7 5.3 1.5 94 11 117 255 -4.3 0.1 -3.9 -4.6 10/29/2005 10:30:00 4 0.9 6.1 1.9 3.8 1 5.7 1.9 3.6 0.8 5.7 1.1 94 11 110 255 -4.2 0 -3.9 -4.4 10/29/2005 10:40:00 3.4 1.1 5.7 0.7 3.4 1.1 5.7 0.7 3 1 5.3 1.1 94 15 97 255 -3.8 0 -3.5 -3.9 10/29/2005 10:50:00 3.7 0.9 6.5 0.7 3.7 0.9 6.8 0.7 3.3 0.9 5.7 0.7 97 15 94 255 -3.6 0 -3.5 -3.7 10/29/2005 11:00:00 3.7 1 6.8 1.1 3.7 1 6.1 1.1 3.2 1.1 5.7 0.7 102 15 104 255 -3.7 0 -3.5 -3.7 10/29/2005 11:10:00 4 0.9 6.1 1.5 4 0.8 6.1 1.9 3.5 0.8 5.7 1.9 104 10 106 255 -3.5 0 -3.3 -3.5 10/29/2005 11:20:00 3.2 0.7 5.7 1.9 3.3 0.7 5.7 1.9 3 0.8 4.9 0.4 99 14 84 255 -2.9 0.1 -2.6 -3.5 10/29/2005 11:30:00 3.5 0.8 5.7 1.1 3.5 0.8 6.1 1.5 3.1 0.8 4.9 1.1 101 12 97 255 -2.7 0 -2.6 -2.8 10/29/2005 11:40:00 3.2 0.9 5.7 0.7 3.2 0.9 5.3 0.4 2.8 0.9 4.9 0.7 96 17 98 255 -2.8 0 -2.6 -2.8 10/29/2005 11:50:00 2 0.9 4.2 0.4 2.2 0.9 4.2 0.4 1.8 0.8 3.8 0.4 93 20 72 255 -2.6 0 -2.4 -2.8 10/29/2005 12:00:00 2.3 0.9 4.9 0.4 2.4 0.9 4.6 0.4 2 0.8 3.8 0.4 91 19 101 255 -2.3 0 -2.1 -2.6 10/29/2005 12:10:00 2.3 1 4.6 0.4 2.5 1 4.6 0.4 2.3 1.1 4.2 0.4 100 16 108 255 -2 0.1 -1.4 -2.1 10/29/2005 12:20:00 2.5 0.7 3.8 0.4 2.6 0.7 4.2 0.7 2.3 0.8 4.2 0.4 96 18 110 255 -1.6 0 -1.4 -1.7 10/29/2005 12:30:00 1.7 0.9 3.4 0.4 1.9 0.8 3.8 0.4 1.6 0.7 3.4 0.4 87 20 80 255 -1.6 0 -1.4 -1.9 10/29/2005 12:40:00 1.7 0.8 3.4 0.4 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 73 15 78 255 -1.8 0 -1.7 -1.9 10/29/2005 12:50:00 1.7 0.6 3.4 0.4 2 0.5 3.4 1.1 1.8 0.6 3 0.4 75 16 90 255 -1.7 0 -1.4 -1.9 10/29/2005 13:00:00 1.9 0.5 3 0.4 2.2 0.4 3.4 1.1 2 0.5 3 0.4 71 12 76 255 -1.5 0 -1.2 -1.4 10/29/2005 13:10:00 1 0.6 3 0.4 1.4 0.6 3.4 0.4 1.3 0.6 2.6 0.4 66 23 62 255 -0.9 0.2 -0.5 -1.4 10/29/2005 13:20:00 0.6 0.4 2.3 0.4 1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 77 26 57 255 -0.2 0 -0.1 -0.5 10/29/2005 13:30:00 0.4 0.1 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 36 20 82 255 0.1 0 0.2 -0.3 10/29/2005 13:40:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 28 19 19 255 0.2 0 0.4 -0.1 10/29/2005 13:50:00 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 11 15 19 255 0.6 0.2 1.4 0.2 10/29/2005 14:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 9 4 7 255 1.2 0 1.6 1.1 10/29/2005 14:10:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 352 32 294 255 1.4 0.3 1.8 0.9 10/29/2005 14:20:00 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.1 0.4 305 26 277 255 1.5 0.2 1.8 0.9 10/29/2005 14:30:00 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 323 28 284 255 1.4 0.1 1.8 1.4 10/29/2005 14:40:00 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 2 19 17 255 0.7 0.2 1.4 0.2 10/29/2005 14:50:00 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 318 10 322 255 0.3 0.1 0.7 0.2 10/29/2005 15:00:00 0.7 0.5 2.3 0.4 1.2 0.4 2.6 0.4 1 0.5 2.3 0.4 322 13 313 255 0.4 0.1 0.7 -0.1 10/29/2005 15:10:00 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 301 11 321 255 -0.6 0.3 0.2 -1 10/29/2005 15:20:00 0.6 0.4 1.5 0.4 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 287 13 291 255 -1.2 0.2 -0.7 -1.4 10/29/2005 15:30:00 0.6 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 311 11 304 255 -1.6 0 -1.4 -1.9 10/29/2005 15:40:00 0.7 0.4 1.9 0.4 1.3 0.3 2.3 0.4 0.9 0.4 1.9 0.4 302 9 316 255 -2.1 0 -1.9 -2.4 10/29/2005 15:50:00 0.5 0.3 1.5 0.4 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 292 10 304 255 -2.1 0 -1.9 -2.1 10/29/2005 16:00:00 1.2 0.5 2.3 0.4 1.6 0.4 2.3 0.4 1.3 0.6 2.6 0.4 288 8 290 255 -2.4 0.1 -2.1 -2.6 10/29/2005 16:10:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 305 11 288 255 -2.6 0 -2.4 -2.8 10/29/2005 16:20:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 302 15 303 255 -2.9 0 -2.6 -3 10/29/2005 16:30:00 1.1 0.5 2.3 0.4 1.5 0.4 2.3 0.4 0.9 0.5 2.3 0.4 277 12 286 255 -3.4 0.2 -3 -3.7 10/29/2005 16:40:00 0.6 0.3 1.5 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 260 11 270 255 -3.7 0.1 -3.3 -3.9 10/29/2005 16:50:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 257 7 267 255 -3.8 0 -3.7 -3.9 10/29/2005 17:00:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 229 23 258 255 -4.2 0.2 -3.9 -4.6 10/29/2005 17:10:00 0.4 0.2 1.5 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.5 0.4 230 102 138 255 -4.8 0 -4.4 -4.8 10/29/2005 17:20:00 0.6 0.5 2.6 0.4 1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 95 24 61 255 -5 0 -4.8 -5.3 10/29/2005 17:30:00 1.9 0.8 4.2 0.4 2.3 0.7 4.2 0.7 1.4 0.6 3.4 0.4 98 15 95 255 -5.3 0 -5 -5.5 10/29/2005 17:40:00 1.5 1 3.8 0.4 1.9 0.9 4.2 0.4 1.2 0.7 3 0.4 84 13 74 255 -4.9 0 -4.8 -5.3 10/29/2005 17:50:00 2.2 0.7 4.2 0.4 2.4 0.6 3.8 0.7 1.6 0.6 3.4 0.4 91 13 88 255 -4.7 0.1 -4.6 -4.8 10/29/2005 18:00:00 2.7 0.7 4.6 0.4 2.9 0.6 4.6 1.1 2 0.7 3.8 0.4 94 12 102 255 -4.3 0 -4.4 -4.6 10/29/2005 18:10:00 3.9 0.9 6.5 1.9 3.9 0.9 6.5 1.9 3.2 1 6.1 1.1 97 13 90 255 -3.9 0.2 -3.5 -4.4 10/29/2005 18:20:00 4.6 1.1 7.6 1.5 4.7 1 6.8 2.3 3.8 1 6.5 1.1 94 14 97 255 -3.4 0 -3.3 -3.5 10/29/2005 18:30:00 4.9 1.2 8 2.3 4.9 1.2 8.4 2.6 4.2 1.2 7.2 1.9 94 18 94 255 -3.3 0 -3.3 -3.5 10/29/2005 18:40:00 5.8 1.3 9.5 2.3 5.9 1.2 8.4 2.6 5 1.3 8.4 1.5 93 15 111 255 -3.2 0 -3.3 -3.3 10/29/2005 18:50:00 5.4 1.4 9.5 2.6 5.3 1.4 10.3 2.6 4.6 1.2 8.4 2.6 92 16 102 255 -3.2 0 -3.3 -3.5 10/29/2005 19:00:00 4.5 1.1 6.8 1.9 4.4 1.2 6.8 1.1 3.5 1.1 6.5 0.7 81 16 58 255 -3.5 0 -3.3 -3.7 10/29/2005 19:10:00 4.6 1.1 7.6 1.9 4.5 1.2 8 1.9 3.8 1.1 7.6 1.5 81 15 93 255 -3.7 0 -3.5 -3.7 10/29/2005 19:20:00 4.2 1.3 8.4 1.9 4.2 1.4 8 1.5 3.5 1.1 7.2 0.7 84 18 88 255 -3.7 0 -3.5 -3.7 10/29/2005 19:30:00 4.4 1.2 7.2 1.5 4.4 1.1 7.6 1.5 3.6 1.2 6.8 0.4 83 19 84 255 -3.7 0 -3.5 -3.7 10/29/2005 19:40:00 4.7 1.2 8 2.3 4.7 1.1 8 2.3 4.1 1.2 7.2 1.1 82 17 78 255 -3.8 0 -3.5 -3.7 10/29/2005 19:50:00 5.2 1.2 8.4 1.9 5.2 1.2 8.4 2.3 4.5 1.3 7.6 1.1 82 16 94 255 -3.8 0 -3.5 -3.7 10/29/2005 20:00:00 4.9 1.3 8.4 2.3 5 1.2 8 1.9 4 1.5 7.6 1.1 87 16 85 255 -3.8 0 -3.5 -3.9 10/29/2005 20:10:00 5.4 1.4 9.5 2.6 5.5 1.4 9.5 2.6 4.6 1.5 8.4 1.5 90 20 93 255 -3.8 0 -3.7 -3.9 10/29/2005 20:20:00 5.5 1.5 9.5 1.1 5.5 1.5 9.1 1.1 4.6 1.3 8.4 1.1 91 18 91 255 -3.9 0 -3.7 -3.9 10/29/2005 20:30:00 5.5 1.3 9.1 1.9 5.6 1.3 8.8 1.9 4.6 1.3 8.8 1.9 92 16 102 255 -3.9 0 -3.7 -4.2 10/29/2005 20:40:00 5.3 1.5 9.1 1.5 5.4 1.5 9.1 1.5 4.6 1.4 8.4 0.7 92 18 73 255 -4 0 -3.9 -4.2 10/29/2005 20:50:00 5.1 1.6 9.5 1.5 5.1 1.6 10.3 1.9 4.4 1.5 8.8 1.1 92 21 112 255 -4 0 -3.9 -4.2 10/29/2005 21:00:00 5.6 1.3 8.8 2.6 5.6 1.3 8.8 2.6 4.5 1.3 8.4 1.9 92 17 74 255 -4.1 0 -3.9 -4.2 10/29/2005 21:10:00 4.5 1.4 8 0.4 4.5 1.3 8 0.4 3.7 1.3 8 0.4 81 19 78 255 -4.2 0 -3.9 -4.4 10/29/2005 21:20:00 4 1.3 9.1 1.1 3.9 1.3 8.8 1.1 3.4 1.4 6.8 0.4 83 20 97 255 -4.3 0 -3.9 -4.4 10/29/2005 21:30:00 5.1 1.5 9.5 1.9 5.1 1.5 9.1 1.9 4.2 1.4 8 0.7 85 20 100 255 -4.2 0.1 -3.9 -4.4 10/29/2005 21:40:00 5 1.5 10.7 1.9 5 1.5 10.7 1.9 4.3 1.5 9.1 0.4 90 22 121 255 -4 0 -3.9 -4.2 10/29/2005 21:50:00 5.1 1.7 10.3 1.5 5 1.7 10.7 1.9 4.2 1.5 8.4 1.1 87 21 116 255 -4 0 -3.9 -4.2 10/29/2005 22:00:00 4.9 1.9 9.9 0.4 5 1.7 9.9 0.7 4.1 1.7 9.5 1.5 92 26 105 255 -4.1 0 -3.9 -4.2 10/29/2005 22:10:00 4.9 1.5 8.8 1.5 4.9 1.5 9.1 1.5 4.1 1.4 8.4 1.1 83 22 87 255 -4.2 0 -3.9 -4.4 10/29/2005 22:20:00 3.9 1.2 7.6 0.7 4 1.2 8.4 1.5 3.4 1.1 6.8 0.7 73 20 100 255 -4.2 0 -4.2 -4.4 10/29/2005 22:30:00 4.4 1.3 8.8 1.1 4.4 1.3 8.4 1.1 3.7 1.3 7.6 0.4 89 19 115 255 -4.3 0 -4.2 -4.4 10/29/2005 22:40:00 5.5 1.5 9.1 2.3 5.6 1.4 9.1 2.3 4.5 1.4 8.8 1.1 89 18 96 255 -4.2 0 -3.9 -4.4 10/29/2005 22:50:00 4.8 1.4 8.8 1.9 4.9 1.4 8.8 1.5 3.9 1.3 7.2 0.7 85 21 114 255 -4.2 0 -3.9 -4.4 10/29/2005 23:00:00 4.2 1.2 7.6 1.1 4.2 1.1 7.2 1.5 3.6 1.1 6.5 0.7 89 22 58 255 -4.2 0 -3.9 -4.4 10/29/2005 23:10:00 4.8 1.6 9.1 1.1 4.8 1.5 9.1 1.1 3.8 1.3 7.2 0.4 90 22 64 255 -4.2 0 -3.9 -4.4 10/29/2005 23:20:00 6.3 1.7 10.3 2.3 6.4 1.7 10.3 2.3 5.5 1.7 9.5 1.1 99 17 101 255 -4 0 -3.7 -4.2 10/29/2005 23:30:00 6.7 1.7 11.8 2.3 6.9 1.6 11.5 3 5.7 1.7 9.9 1.5 103 18 111 255 -3.8 0 -3.7 -3.9 10/29/2005 23:40:00 6.7 1.5 10.7 3 6.7 1.5 10.7 3 5.7 1.4 9.5 1.9 103 18 101 255 -3.9 0 -3.7 -3.9 10/29/2005 23:50:00 7.1 1.7 12.2 2.6 7.1 1.7 11.8 1.9 6.2 1.5 9.9 2.6 104 17 95 255 -3.9 0 -3.7 -3.9 10/30/2005 00:00:00 7.5 1.9 12.2 2.6 7.5 1.9 11.8 2.6 6.4 1.8 10.7 1.9 107 17 105 255 -3.9 0 -3.7 -3.9 10/30/2005 00:10:00 7.6 1.7 13 3.4 7.5 1.7 12.2 3.8 6.5 1.7 11.5 2.6 104 16 102 255 -3.9 0 -3.7 -3.9 10/30/2005 00:20:00 7.7 1.8 11.5 3.4 7.6 1.7 11.5 3.4 6.6 1.8 11.8 2.6 105 17 84 255 -3.8 0 -3.7 -3.9 10/30/2005 00:30:00 7.1 1.8 12.6 2.6 7.1 1.7 12.2 3 6.1 1.5 11.1 1.9 102 16 102 255 -3.8 0 -3.7 -3.9 10/30/2005 00:40:00 7.3 1.6 11.5 2.6 7.3 1.5 11.8 2.6 6.2 1.6 9.5 1.5 102 16 115 255 -3.8 0 -3.7 -3.9 10/30/2005 00:50:00 6.9 1.6 11.1 2.6 6.9 1.6 11.5 3 5.6 1.7 10.3 2.3 97 17 96 255 -3.8 0 -3.7 -3.9 10/30/2005 01:00:00 5.8 1.6 10.3 1.9 5.8 1.7 10.3 1.9 5.2 1.5 9.9 1.9 100 21 73 255 -3.8 0 -3.5 -3.7 10/30/2005 01:10:00 6.4 1.4 9.5 2.6 6.5 1.4 9.5 1.9 5.4 1.4 8.4 1.5 98 16 108 255 -3.6 0 -3.5 -3.7 10/30/2005 01:20:00 4.8 1.4 10.3 2.3 4.9 1.4 9.1 2.3 3.9 1.2 7.6 1.5 78 23 80 255 -3.5 0 -3.5 -3.5 10/30/2005 01:30:00 2.8 1.1 5.7 0.4 2.9 1.1 6.1 0.4 2.4 1.1 4.9 0.4 72 23 83 255 -3.5 0 -3.3 -3.5 10/30/2005 01:40:00 3.7 1.3 7.2 0.4 3.8 1.2 6.8 1.1 3.1 1.3 6.8 0.4 74 18 91 255 -3.4 0 -3.3 -3.5 10/30/2005 01:50:00 5.2 1.3 8.8 1.1 5.2 1.3 9.5 2.3 4.5 1.3 8.4 1.9 82 16 94 255 -3.4 0 -3.3 -3.5 10/30/2005 02:00:00 4.6 1.2 8 1.9 4.6 1.3 8.4 1.5 4.1 1.1 7.2 1.5 74 18 100 255 -3.4 0 -3.3 -3.5 10/30/2005 02:10:00 5.2 1.3 8.4 2.3 5.1 1.2 8.4 2.3 4.5 1.2 8.4 2.3 84 16 80 255 -3.5 0 -3.3 -3.5 10/30/2005 02:20:00 4.2 1.5 7.2 0.7 4.1 1.5 7.6 0.4 3.4 1.4 6.8 0.4 88 21 71 255 -3.5 0 -3.5 -3.5 10/30/2005 02:30:00 4.9 1.4 9.1 1.9 4.9 1.3 8.8 1.9 4.3 1.4 9.1 1.1 88 20 92 255 -3.5 0 -3.3 -3.5 10/30/2005 02:40:00 4.6 1.4 8.4 1.1 4.7 1.4 9.1 1.5 4.1 1.3 7.2 1.1 90 17 71 255 -3.5 0 -3.3 -3.5 10/30/2005 02:50:00 4.6 1.2 8.8 1.5 4.6 1.2 9.1 1.1 3.9 1.1 7.6 1.5 84 19 94 255 -3.4 0 -3.3 -3.5 10/30/2005 03:00:00 4.9 1.4 9.1 1.5 4.9 1.4 9.1 0.7 4.3 1.1 8 1.9 86 18 97 255 -3.3 0 -3.3 -3.5 10/30/2005 03:10:00 3.6 1.2 6.5 0.7 3.6 1.3 6.8 0.4 3.1 1.2 6.5 0.4 74 20 77 255 -3.2 0 -3.3 -3.3 10/30/2005 03:20:00 4 1.2 7.6 1.5 4.1 1.2 7.6 1.1 3.5 1 6.8 1.5 84 17 99 255 -3.1 0 -3 -3.3 10/30/2005 03:30:00 4.6 1.2 6.8 1.1 4.6 1.2 7.2 1.5 3.8 1.2 6.8 0.7 81 15 85 255 -3.1 0 -3 -3.3 10/30/2005 03:40:00 4.8 1.1 7.6 1.5 4.9 1.1 7.6 1.9 4.1 1.1 7.2 1.9 84 16 88 255 -3.1 0 -3 -3.3 10/30/2005 03:50:00 3.7 1.1 7.2 1.1 3.8 1.2 7.2 1.5 3 1.1 6.1 0.4 80 16 94 255 -3 0 -2.8 -3.3 10/30/2005 04:00:00 3.9 1 6.8 1.9 3.9 1 6.8 1.9 3.2 1.1 6.8 0.4 73 19 74 255 -3 0 -2.8 -3.3 10/30/2005 04:10:00 4.1 1.1 6.8 1.1 4.1 1.1 6.8 0.7 3.5 1 6.8 0.7 76 19 90 255 -3.1 0 -3 -3.3 10/30/2005 04:20:00 3.9 0.9 6.1 1.5 3.8 0.9 5.7 1.5 3.3 1 5.7 1.1 71 17 95 255 -3 0 -2.8 -3 10/30/2005 04:30:00 4.4 1.2 8.4 1.9 4.4 1.2 8.8 1.5 3.8 1.3 8.4 0.4 87 18 83 255 -2.8 0 -2.6 -3 10/30/2005 04:40:00 3.2 1.1 7.2 0.7 3.2 1.1 7.2 0.4 2.4 1 5.3 0.4 79 24 98 255 -2.8 0 -2.6 -2.8 10/30/2005 04:50:00 2.9 1.1 6.1 0.4 2.9 1.3 5.7 0.4 2.3 1 4.9 0.4 48 33 72 255 -2.8 0 -2.6 -3 10/30/2005 05:00:00 2.9 1 6.1 0.7 2.8 1 6.1 0.4 2.4 1 4.9 0.4 56 22 45 255 -3.1 0 -2.8 -3.3 10/30/2005 05:10:00 2.1 0.5 3.4 0.7 1.9 0.5 3.4 0.4 1.6 0.5 2.6 0.4 37 11 46 255 -3.4 0.1 -3.3 -3.5 10/30/2005 05:20:00 2.1 0.5 4.2 1.1 2.1 0.5 4.2 0.4 1.7 0.6 3.8 0.4 38 22 58 255 -3.7 0 -3.5 -3.7 10/30/2005 05:30:00 1.6 0.3 2.3 0.4 1.5 0.4 2.3 0.4 1.1 0.4 1.9 0.4 28 9 21 255 -3.8 0 -3.7 -3.9 10/30/2005 05:40:00 1.4 0.4 2.6 0.4 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 47 13 36 255 -3.9 0 -3.7 -3.9 10/30/2005 05:50:00 1.2 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 33 5 47 255 -3.9 0 -3.9 -3.9 10/30/2005 06:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 54 12 70 255 -4 0 -3.9 -4.2 10/30/2005 06:10:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 35 15 58 255 -4 0 -3.9 -3.9 10/30/2005 06:20:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 34 13 57 255 -4 0 -3.9 -3.9 10/30/2005 06:30:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 38 12 62 255 -3.9 0 -3.9 -3.9 10/30/2005 06:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 8 13 26 255 -3.9 0 -3.7 -3.9 10/30/2005 06:50:00 1.3 0.4 1.9 0.4 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 17 10 2 255 -3.9 0 -3.7 -3.9 10/30/2005 07:00:00 1.1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.9 0.4 30 11 20 255 -3.9 0 -3.7 -3.9 10/30/2005 07:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 32 10 40 255 -3.8 0 -3.7 -3.9 10/30/2005 07:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 45 7 33 255 -3.8 0 -3.7 -3.9 10/30/2005 07:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 34 7 45 255 -3.8 0 -3.7 -3.9 10/30/2005 07:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 33 0 32 255 -3.8 0 -3.7 -3.7 10/30/2005 07:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1 17 351 255 -3.8 0 -3.5 -3.7 10/30/2005 08:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 3 12 17 255 -3.8 0 -3.7 -3.9 10/30/2005 08:10:00 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0 0.7 0.4 44 23 52 255 -4 0 -3.9 -4.2 10/30/2005 08:20:00 1.5 0.8 3.8 0.4 1.4 0.9 4.2 0.4 1 0.6 3.4 0.4 44 22 89 255 -4.2 0 -3.9 -4.4 10/30/2005 08:30:00 1.7 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.2 0.6 3 0.4 39 20 33 255 -4.2 0 -3.9 -4.4 10/30/2005 08:40:00 2 0.7 4.6 0.4 2 0.8 4.9 0.4 1.4 0.6 3.4 0.4 30 30 73 255 -4.1 0 -3.9 -4.4 10/30/2005 08:50:00 1 0.6 3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 347 23 345 255 -4.5 0 -4.4 -4.6 10/30/2005 09:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 357 35 346 255 -4.7 0 -4.6 -4.8 10/30/2005 09:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.9 0.4 297 17 294 255 -4.8 0 -4.6 -4.8 10/30/2005 09:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 234 9 253 255 -4.8 0 -4.6 -4.8 10/30/2005 09:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 274 43 14 255 -4.7 0 -4.6 -4.8 10/30/2005 09:40:00 0.6 0.5 3 0.4 0.6 0.5 2.6 0.4 0.5 0.4 1.9 0.4 264 76 108 255 -4.8 0 -4.6 -4.8 10/30/2005 09:50:00 1.5 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.2 0.5 2.3 0.4 64 32 99 255 -4.7 0.1 -4.4 -4.8 10/30/2005 10:00:00 1.6 0.4 2.6 0.7 1.5 0.5 3 0.4 1.4 0.4 2.3 0.4 19 16 47 255 -4.2 0.1 -3.9 -4.4 10/30/2005 10:10:00 1.3 0.7 3 0.4 1 0.6 2.6 0.4 1 0.5 2.6 0.4 347 14 2 255 -3.8 0 -3.5 -3.9 10/30/2005 10:20:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.5 0.4 10 29 62 255 -3.5 0 -3.3 -3.7 10/30/2005 10:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 15 28 25 255 -3.3 0 -3.3 -3.5 10/30/2005 10:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.1 0.4 333 26 11 255 -3.2 0 -3 -3.3 10/30/2005 10:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 341 17 11 255 -3 0 -2.6 -3.3 10/30/2005 11:00:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 332 14 324 255 -2.6 0 -2.1 -2.8 10/30/2005 11:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 321 24 312 255 -2 0.1 -1.9 -2.4 10/30/2005 11:20:00 0.6 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 321 17 333 255 -1.7 0 -1.7 -1.9 10/30/2005 11:30:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 338 13 337 255 -1.8 0 -1.7 -1.9 10/30/2005 11:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 343 22 3 255 -2 0 -1.9 -2.1 10/30/2005 11:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 326 0 326 255 -2.1 0 -2.1 -2.1 10/30/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 291 5 255 255 -2.1 0 -2.1 -2.1 10/30/2005 12:10:00 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 302 11 313 255 -2.1 0 -1.9 -2.1 10/30/2005 12:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 334 22 292 255 -1.8 0 -1.7 -2.1 10/30/2005 12:30:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.1 0.6 2.3 0.4 297 18 281 255 -1.8 0 -1.7 -1.9 10/30/2005 12:40:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 300 17 295 255 -1.7 0 -1.4 -1.9 10/30/2005 12:50:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.6 0.4 2.3 0.4 300 10 286 255 -1.6 0 -1.4 -1.7 10/30/2005 13:00:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.4 1.9 0.4 299 11 310 255 -1.5 0 -1.2 -1.7 10/30/2005 13:10:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 1.4 0.7 2.6 0.4 301 15 281 255 -0.9 0.1 -0.7 -1.2 10/30/2005 13:20:00 1.4 0.5 3 0.4 1.2 0.5 2.6 0.4 1.4 0.6 3 0.4 305 17 320 255 -0.4 0.1 0.2 -0.7 10/30/2005 13:30:00 1.7 0.5 3 0.7 1.5 0.6 3 0.4 1.4 0.6 3 0.4 312 14 318 255 -0.2 0.2 0.2 -0.5 10/30/2005 13:40:00 1.8 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.7 0.6 3 0.4 289 13 302 255 -0.5 0 -0.5 -0.5 10/30/2005 13:50:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.3 0.6 2.6 0.4 301 17 299 255 -0.3 0.2 0.2 -0.5 10/30/2005 14:00:00 1.4 0.8 3 0.4 1.2 0.8 3 0.4 1 0.7 3 0.4 285 24 268 255 0 0.1 0.2 -0.3 10/30/2005 14:10:00 1.3 0.5 2.6 0.4 0.9 0.6 2.6 0.4 1.1 0.6 2.3 0.4 295 20 269 255 -0.3 0 -0.1 -0.5 10/30/2005 14:20:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 1.4 0.6 2.6 0.4 307 12 301 255 0.1 0 0.4 -0.1 10/30/2005 14:30:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 307 11 297 255 0.2 0 0.4 0.2 10/30/2005 14:40:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 294 26 337 255 -0.2 0.2 0.2 -0.5 10/30/2005 14:50:00 1.1 0.5 3 0.4 1.1 0.5 2.6 0.4 1 0.6 2.6 0.4 295 16 309 255 -0.3 0 -0.1 -0.5 10/30/2005 15:00:00 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 305 11 322 255 -0.2 0 -0.1 -0.3 10/30/2005 15:10:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 311 12 310 255 -0.7 0.2 -0.3 -1.2 10/30/2005 15:20:00 0.7 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 314 18 296 255 -1.4 0 -1.2 -1.4 10/30/2005 15:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 341 6 356 255 -1.7 0 -1.4 -1.9 10/30/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 353 0 255 255 -2.1 0 -1.9 -2.4 10/30/2005 15:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 342 10 336 255 -2.5 0 -2.1 -2.6 10/30/2005 16:00:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 314 17 305 255 -2.9 0.1 -2.6 -3 10/30/2005 16:10:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 305 5 289 255 -3.1 0 -2.8 -3.3 10/30/2005 16:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 287 16 285 255 -3.5 0 -3.3 -3.5 10/30/2005 16:30:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.1 0.4 288 6 281 255 -3.5 0 -3.5 -3.5 10/30/2005 16:40:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 286 8 295 255 -3.7 0 -3.5 -3.7 10/30/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 278 0 255 255 -3.8 0 -3.5 -4.2 10/30/2005 17:00:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 343 12 353 255 -4.3 0.1 -3.9 -4.6 10/30/2005 17:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 358 7 353 255 -4.7 0 -4.6 -4.8 10/30/2005 17:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 9 0 9 255 -4.9 0 -4.8 -5 10/30/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 0 255 255 -5 0.1 -4.8 -5.3 10/30/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 0 255 255 -5.4 0 -5.3 -5.5 10/30/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 0 255 255 -5.6 0 -5.5 -5.7 10/30/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 0 255 255 -5.9 0 -5.7 -6.1 10/30/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 36 255 255 -6.3 0 -6.1 -6.4 10/30/2005 18:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 176 36 211 255 -6.1 0 -6.1 -6.1 10/30/2005 18:30:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 210 0 211 255 -6.2 0 -6.1 -6.4 10/30/2005 18:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.5 0.4 173 32 211 255 -6.6 0 -6.1 -6.8 10/30/2005 18:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 138 12 126 255 -6.9 0 -6.8 -7 10/30/2005 19:00:00 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 0.5 0.2 1.5 0.4 81 17 92 255 -7.1 0 -6.8 -7 10/30/2005 19:10:00 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.6 0.3 1.5 0.4 66 11 48 255 -7.2 0 -7 -7.2 10/30/2005 19:20:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.4 0.3 1.9 0.4 86 8 94 255 -7.3 0 -7 -7.4 10/30/2005 19:30:00 1.6 0.3 2.3 1.1 1.6 0.3 2.3 1.1 1 0.4 1.9 0.4 84 6 85 255 -7.3 0 -7 -7.4 10/30/2005 19:40:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 0.7 0.3 1.5 0.4 101 6 113 255 -7.2 0 -7 -7.4 10/30/2005 19:50:00 1.9 0.4 3.4 1.1 1.9 0.4 3.4 1.1 1.1 0.5 2.3 0.4 100 6 94 255 -7.1 0 -7 -7.2 10/30/2005 20:00:00 2.7 0.5 3.8 1.9 2.7 0.5 4.2 1.9 1.8 0.5 3.4 0.7 81 8 77 255 -7.3 0 -7 -7.4 10/30/2005 20:10:00 2 0.4 3 1.1 1.9 0.4 3 0.7 1.3 0.5 2.6 0.4 81 8 82 255 -7.3 0.1 -7.2 -7.4 10/30/2005 20:20:00 1.9 0.6 4.2 0.7 1.8 0.6 3.8 0.4 1 0.4 2.3 0.4 85 12 93 255 -7.4 0 -7.2 -7.4 10/30/2005 20:30:00 3 0.7 5.3 1.5 2.9 0.7 5.3 0.7 2.2 0.6 3.8 0.7 91 13 83 255 -6.9 0.3 -6.1 -7.2 10/30/2005 20:40:00 2.7 0.6 4.6 0.7 2.7 0.6 4.2 0.7 2 0.6 3.8 0.4 85 15 98 255 -5.6 0.3 -5 -6.4 10/30/2005 20:50:00 3.3 0.7 5.3 1.5 3.2 0.7 5.3 1.5 2.5 0.7 4.9 0.7 90 13 123 255 -4.9 0.1 -4.6 -5 10/30/2005 21:00:00 3.8 1 6.1 1.9 3.8 1 6.1 1.5 2.9 1 5.3 0.7 93 13 87 255 -4.1 0.2 -3.7 -4.6 10/30/2005 21:10:00 5 1 7.2 2.6 5 1 7.2 2.6 4.2 1 6.8 1.5 95 15 99 255 -3.4 0.2 -3 -3.7 10/30/2005 21:20:00 3.5 1.3 7.2 1.1 3.5 1.3 7.6 1.1 2.9 1.3 6.8 0.4 77 17 88 255 -3.1 0 -3 -3.3 10/30/2005 21:30:00 3.1 0.7 5.3 1.5 3.2 0.7 5.3 1.1 2.4 0.8 4.2 0.7 83 17 68 255 -3.4 0 -3.3 -3.5 10/30/2005 21:40:00 2.5 0.8 5.3 0.4 2.5 0.8 4.9 0.4 1.9 0.8 4.2 0.4 81 15 87 255 -3.5 0 -3.3 -3.5 10/30/2005 21:50:00 2.4 0.8 4.6 0.7 2.4 0.8 4.6 0.7 1.8 0.7 3.8 0.4 89 13 94 255 -3.8 0 -3.5 -3.9 10/30/2005 22:00:00 2.6 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.1 0.5 3.4 0.7 78 11 75 255 -4 0.1 -3.9 -4.4 10/30/2005 22:10:00 3 0.5 4.2 1.9 3 0.5 4.2 1.5 2.1 0.6 3.4 0.7 90 10 71 255 -4.5 0.1 -3.9 -4.8 10/30/2005 22:20:00 2.6 0.7 4.6 0.7 2.6 0.7 4.6 0.7 1.7 0.7 3.8 0.4 94 13 96 255 -5.3 0.2 -4.6 -5.7 10/30/2005 22:30:00 2.4 0.8 4.2 0.7 2.4 0.8 4.6 0.7 1.5 0.8 3.8 0.4 100 18 82 255 -5.3 0.1 -5 -5.7 10/30/2005 22:40:00 2.5 0.8 4.2 0.4 2.5 0.8 4.6 0.4 1.8 0.8 3.8 0.4 111 23 128 255 -4.5 0.2 -4.4 -5 10/30/2005 22:50:00 2.1 0.7 3.8 0.4 2.1 0.7 4.2 0.4 1.5 0.6 3 0.4 89 15 105 255 -4.8 0 -4.4 -5 10/30/2005 23:00:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.4 0.6 3 0.4 93 15 108 255 -4.9 0 -4.6 -5 10/30/2005 23:10:00 2.3 0.7 4.2 0.4 2.3 0.7 4.2 0.7 1.7 0.6 3.8 0.4 84 15 91 255 -5.2 0.1 -4.8 -5.5 10/30/2005 23:20:00 1.4 0.6 2.6 0.4 1.5 0.6 3 0.4 0.9 0.5 2.6 0.4 78 13 68 255 -5.5 0.1 -5 -5.7 10/30/2005 23:30:00 0.9 0.5 2.3 0.4 1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 83 7 81 255 -6.1 0.2 -5.7 -6.6 10/30/2005 23:40:00 0.4 0.1 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0 0.4 0.4 77 0 78 255 -6.7 0 -6.4 -6.8 10/30/2005 23:50:00 0.7 0.6 3.4 0.4 0.8 0.7 3 0.4 0.4 0.2 1.1 0.4 65 14 79 255 -6.8 0.1 -6.6 -7 10/31/2005 00:00:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 0.7 0.4 1.9 0.4 66 8 74 255 -7.3 0.2 -7 -7.6 10/31/2005 00:10:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 80 14 74 255 -7.7 0 -7.6 -7.9 10/31/2005 00:20:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 0.9 0.5 2.3 0.4 93 13 92 255 -7.5 0 -7.4 -7.6 10/31/2005 00:30:00 2.6 0.7 4.6 1.1 2.6 0.6 4.6 1.1 1.6 0.7 3.8 0.4 99 15 121 255 -7.5 0 -7 -7.6 10/31/2005 00:40:00 3.4 0.8 5.3 1.1 3.5 0.8 5.3 0.7 2.5 0.7 4.6 0.7 109 14 97 255 -6.2 0.5 -5.3 -7 10/31/2005 00:50:00 3.8 0.8 6.5 1.9 3.8 0.8 6.5 1.9 2.9 0.8 4.9 1.1 111 14 132 255 -4.7 0.3 -4.4 -5.3 10/31/2005 01:00:00 3.5 0.8 5.7 1.9 3.5 0.8 5.7 1.9 2.8 0.9 5.3 0.7 110 13 133 255 -4.3 0 -4.2 -4.4 10/31/2005 01:10:00 3.6 0.9 5.7 0.7 3.6 0.9 5.3 0.7 2.8 1 5.3 0.4 102 15 97 255 -4 0 -3.9 -4.2 10/31/2005 01:20:00 2.8 1 5.7 0.4 2.8 1 5.3 0.7 2.2 1 4.9 0.4 93 13 87 255 -3.9 0 -3.9 -3.9 10/31/2005 01:30:00 3.1 1 6.5 0.4 3.2 1 6.1 1.1 2.3 1.1 5.3 0.4 100 18 106 255 -3.8 0 -3.7 -4.2 10/31/2005 01:40:00 3.6 1.2 6.1 0.4 3.7 1.1 6.1 0.7 3 0.9 5.7 0.7 101 16 106 255 -3.7 0 -3.5 -3.7 10/31/2005 01:50:00 2.8 1 5.3 0.7 2.8 1 4.9 0.7 2 0.9 4.6 0.4 93 18 64 255 -3.7 0 -3.5 -3.7 10/31/2005 02:00:00 2.8 0.9 5.3 0.4 2.9 0.9 4.9 1.1 2.1 0.7 4.6 0.7 89 17 98 255 -3.8 0 -3.5 -3.7 10/31/2005 02:10:00 3.9 0.9 6.5 1.5 4 0.9 6.5 1.1 2.9 1 5.3 0.4 100 17 101 255 -3.7 0 -3.5 -3.7 10/31/2005 02:20:00 3.9 0.9 6.5 1.5 4 0.9 6.5 1.9 3.3 1 5.3 1.1 103 16 89 255 -3.5 0 -3.5 -3.5 10/31/2005 02:30:00 3.3 1 6.5 0.7 3.4 1 6.5 0.4 2.7 1 4.9 0.7 99 15 90 255 -3.6 0 -3.5 -3.7 10/31/2005 02:40:00 2.1 0.9 4.9 0.4 2.3 0.9 4.6 0.4 1.7 0.7 3.8 0.4 92 27 89 255 -3.8 0 -3.5 -3.9 10/31/2005 02:50:00 1.7 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.5 0.6 2.6 0.4 57 18 82 255 -4.3 0.2 -3.9 -4.8 10/31/2005 03:00:00 1.3 0.4 2.6 0.4 1.5 0.4 2.6 0.4 0.7 0.3 1.5 0.4 53 12 55 255 -5.2 0.2 -4.6 -5.7 10/31/2005 03:10:00 1.2 0.4 2.6 0.4 1.4 0.4 2.6 0.7 0.6 0.3 1.5 0.4 42 8 42 255 -6.1 0.3 -5.5 -6.6 10/31/2005 03:20:00 1.5 0.4 2.6 0.7 1.6 0.4 2.6 0.7 0.7 0.3 1.5 0.4 49 6 46 255 -6.9 0.1 -6.6 -7 10/31/2005 03:30:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 51 0 51 255 -7.3 0.1 -7 -7.4 10/31/2005 03:40:00 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.5 0.4 51 1 51 255 -7.6 0 -7.2 -7.9 10/31/2005 03:50:00 1.9 0.4 2.6 1.1 2 0.4 2.6 1.1 1.5 0.4 2.3 0.4 54 8 51 255 -8.1 0 -7.9 -8.3 10/31/2005 04:00:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 0.8 0.4 1.9 0.4 72 6 64 255 -8.4 0.1 -8.1 -8.5 10/31/2005 04:10:00 2.5 0.6 3.8 1.1 2.6 0.6 3.8 1.1 1.6 0.5 3.4 0.7 63 8 55 255 -8.4 0.1 -8.3 -8.7 10/31/2005 04:20:00 2.9 0.4 3.8 1.9 3 0.3 3.8 2.3 2.1 0.4 3 1.1 70 7 67 255 -8.6 0.1 -8.3 -8.7 10/31/2005 04:30:00 2 0.4 3 0.7 2.1 0.4 3 1.1 1.1 0.6 2.6 0.4 66 7 77 255 -8.6 0.1 -8.3 -8.9 10/31/2005 04:40:00 1.4 0.4 2.3 0.4 1.4 0.4 2.6 0.4 0.4 0.1 1.1 0.4 62 7 62 255 -9 0.1 -8.7 -9.3 10/31/2005 04:50:00 1.5 0.4 2.3 0.7 1.6 0.4 2.3 0.7 0.4 0.1 1.1 0.4 50 8 64 255 -9.1 0 -8.9 -9.3 10/31/2005 05:00:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 43 0 43 255 -9.4 0 -9.3 -9.3 10/31/2005 05:10:00 0.7 0.5 2.3 0.4 0.8 0.6 2.3 0.4 0.4 0.1 0.7 0.4 111 27 82 255 -9.3 0 -9.3 -9.3 10/31/2005 05:20:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 0.4 0.1 0.7 0.4 50 4 59 255 -9.6 0.1 -9.3 -9.7 10/31/2005 05:30:00 0.9 0.3 1.5 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 66 13 81 255 -9.6 0 -9.3 -9.7 10/31/2005 05:40:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 81 0 81 255 -9.8 0 -9.7 -10.2 10/31/2005 05:50:00 0.8 0.5 1.9 0.4 0.8 0.6 1.9 0.4 0.4 0.2 1.5 0.4 69 14 53 255 -10 0 -10 -10.2 10/31/2005 06:00:00 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.7 0.9 0.2 1.5 0.4 49 3 53 255 -10.1 0 -10 -10.2 10/31/2005 06:10:00 1 0.2 1.5 0.4 1.1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 58 12 46 255 -10 0 -9.7 -10.2 10/31/2005 06:20:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 79 16 99 255 -9.8 0 -9.7 -10 10/31/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 0 255 255 -10.2 0.1 -9.7 -10.4 10/31/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 0 255 255 -10 0 -9.7 -10.2 10/31/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 0 255 255 -10 0 -9.7 -10.2 10/31/2005 07:00:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 295 72 253 255 -10.1 0 -10 -10.2 10/31/2005 07:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 153 17 143 255 -10.2 0 -10 -10.4 10/31/2005 07:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 86 17 81 255 -10.4 0 -10.2 -10.6 10/31/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 255 255 -10.6 0 -10.4 -10.8 10/31/2005 07:40:00 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 81 0 81 255 -10.7 0 -10.6 -11 10/31/2005 07:50:00 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 81 0 81 255 -10.7 0 -10.6 -10.8 10/31/2005 08:00:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 81 0 81 255 -10.7 0 -10.6 -10.8 10/31/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 255 255 -10.7 0 -10.6 -11 10/31/2005 08:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 81 0 255 255 -10.8 0 -10.6 -11 10/31/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 255 255 -10.8 0 -10.6 -11 10/31/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 255 255 -10.8 0 -10.6 -10.8 10/31/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 255 255 -10.7 0 -10.6 -10.8 10/31/2005 09:00:00 0.9 0.4 1.5 0.4 0.9 0.5 1.9 0.4 0.5 0.2 1.1 0.4 182 56 227 255 -10.3 0.1 -10.2 -10.6 10/31/2005 09:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 181 0 181 255 -10.2 0 -10.2 -10.2 10/31/2005 09:20:00 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 163 15 151 255 -9.8 0.1 -9.3 -10.2 10/31/2005 09:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 151 1 151 255 -9.2 0.1 -8.9 -9.3 10/31/2005 09:40:00 1.1 0.2 1.9 0.4 1.2 0.2 1.9 0.7 0.9 0.2 1.9 0.4 158 5 160 255 -9 0 -8.9 -9.1 10/31/2005 09:50:00 1.6 0.4 2.3 0.4 1.7 0.3 2.3 0.4 1.2 0.4 2.3 0.4 164 8 174 255 -8.6 0.2 -8.1 -8.9 10/31/2005 10:00:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 179 11 171 255 -7.9 0.1 -7.6 -8.1 10/31/2005 10:10:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 153 15 185 255 -7.1 0.2 -6.8 -7.6 10/31/2005 10:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 166 13 145 255 -6.7 0.1 -6.1 -7 10/31/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 147 20 108 255 -6.1 0.1 -5.7 -6.4 10/31/2005 10:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 99 14 89 255 -5.5 0.2 -5 -5.7 10/31/2005 10:50:00 1.3 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1 0.4 2.3 0.4 21 36 349 255 -4.9 0 -4.8 -5 10/31/2005 11:00:00 1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 349 12 356 255 -4.9 0 -4.8 -4.8 10/31/2005 11:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 350 15 4 255 -4.7 0.2 -4.4 -4.8 10/31/2005 11:20:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 21 10 22 255 -3.8 0.3 -3.3 -4.4 10/31/2005 11:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 21 22 349 255 -3.6 0.1 -3.5 -3.7 10/31/2005 11:40:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 355 15 14 255 -3.6 0 -3.5 -3.7 10/31/2005 11:50:00 1.7 0.4 3 0.4 1.8 0.4 2.6 0.4 1.4 0.6 2.6 0.4 358 8 353 255 -3.5 0 -3.5 -3.5 10/31/2005 12:00:00 1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 0.8 0.4 2.3 0.4 6 14 11 255 -3.3 0 -3.3 -3.5 10/31/2005 12:10:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.1 0.4 22 19 26 255 -3.1 0.3 -2.4 -3.5 10/31/2005 12:20:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 351 13 318 255 -2.2 0 -1.9 -2.6 10/31/2005 12:30:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 2 19 351 255 -2.8 0.1 -2.4 -3 10/31/2005 12:40:00 1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1 0.4 2.3 0.4 358 9 359 255 -2.9 0 -2.8 -3 10/31/2005 12:50:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 16 22 255 -2.9 0 -2.8 -3 10/31/2005 13:00:00 1.7 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 354 12 353 255 -2.6 0.1 -2.4 -2.8 10/31/2005 13:10:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 347 15 346 255 -2.2 0.1 -2.1 -2.6 10/31/2005 13:20:00 1.4 0.5 2.3 0.4 1.4 0.5 2.6 0.4 0.9 0.4 1.9 0.4 343 17 337 255 -1.7 0.2 -1.4 -2.1 10/31/2005 13:30:00 1.3 0.4 2.6 0.4 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 349 15 349 255 -1.3 0 -1 -1.4 10/31/2005 13:40:00 1.4 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.5 2.3 0.4 354 19 2 255 -1.5 0 -1.2 -1.9 10/31/2005 13:50:00 1.8 0.4 3 0.7 1.9 0.4 3.4 0.7 1.7 0.4 3 0.4 9 9 12 255 -1.6 0 -1.2 -1.7 10/31/2005 14:00:00 1.6 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.3 0.4 2.3 0.4 7 11 1 255 -1.1 0.1 -0.7 -1.4 10/31/2005 14:10:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.2 0.5 2.3 0.4 347 17 355 255 -1.2 0.2 -0.7 -1.4 10/31/2005 14:20:00 1 0.5 1.9 0.4 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 346 15 14 255 -0.9 0.1 -0.7 -1.2 10/31/2005 14:30:00 1.2 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1 16 0 255 -1.4 0.1 -1 -1.4 10/31/2005 14:40:00 1.2 0.5 2.3 0.4 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 357 15 16 255 -1.6 0 -1.2 -1.9 10/31/2005 14:50:00 1.4 0.4 2.3 0.7 1.5 0.4 2.6 0.7 0.8 0.5 2.3 0.4 347 13 355 255 -1.8 0 -1.7 -1.9 10/31/2005 15:00:00 1.2 0.4 2.3 0.4 1.2 0.4 2.6 0.4 0.9 0.5 2.3 0.4 348 14 349 255 -1.7 0 -1.4 -1.9 10/31/2005 15:10:00 0.7 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 359 17 327 255 -2.5 0.3 -1.9 -3 10/31/2005 15:20:00 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.5 0.4 329 21 276 255 -3.4 0.1 -3 -3.5 10/31/2005 15:30:00 1.2 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.7 0.4 1.9 0.4 4 10 1 255 -3.8 0 -3.5 -3.9 10/31/2005 15:40:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.6 0.4 1.9 0.4 13 15 0 255 -4.2 0 -3.9 -4.4 10/31/2005 15:50:00 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 0.5 0.3 1.5 0.4 9 4 13 255 -4.5 0.1 -4.4 -4.8 10/31/2005 16:00:00 1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 0.4 0.2 1.1 0.4 12 4 9 255 -4.9 0 -4.6 -5.3 10/31/2005 16:10:00 0.9 0.2 1.1 0.4 1 0.3 1.5 0.4 0.4 0.1 0.7 0.4 351 6 2 255 -5.3 0 -5 -5.5 10/31/2005 16:20:00 0.6 0.2 1.1 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 353 0 353 255 -5.6 0 -5.5 -5.7 10/31/2005 16:30:00 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 353 0 353 255 -5.9 0 -5.7 -6.1 10/31/2005 16:40:00 0.8 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 353 0 353 255 -6.1 0 -5.9 -6.1 10/31/2005 16:50:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 344 3 343 255 -6 0 -5.9 -6.1 10/31/2005 17:00:00 1.2 0.2 1.9 0.7 1 0.3 1.5 0.4 0.4 0.1 0.7 0.4 343 0 343 255 -6.2 0.1 -5.9 -6.4 10/31/2005 17:10:00 1.1 0.2 1.5 0.7 1.2 0.2 1.5 0.7 0.4 0 0.7 0.4 2 14 343 255 -6.5 0 -6.1 -6.6 10/31/2005 17:20:00 0.8 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 19 0 19 255 -6.8 0 -6.6 -6.8 10/31/2005 17:30:00 1 0.2 1.5 0.7 1.1 0.2 1.5 0.7 0.4 0.1 0.7 0.4 23 5 19 255 -7 0 -6.8 -7 10/31/2005 17:40:00 0.8 0.2 1.1 0.4 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 30 0 30 255 -7.3 0.1 -7 -7.4 10/31/2005 17:50:00 1.7 0.4 2.3 1.1 1.8 0.4 2.6 1.1 0.8 0.3 1.5 0.4 47 10 55 255 -7.5 0 -7.2 -7.6 10/31/2005 18:00:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 0.7 0.4 1.9 0.4 56 7 56 255 -7.9 0.1 -7.6 -8.1 10/31/2005 18:10:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.4 0.6 0.2 1.1 0.4 51 3 55 255 -8.1 0 -7.9 -8.1 10/31/2005 18:20:00 1.7 0.3 2.3 1.1 1.7 0.3 2.6 1.1 0.9 0.3 1.5 0.4 60 4 55 255 -8.2 0 -8.1 -8.3 10/31/2005 18:30:00 1.6 0.4 2.6 0.4 1.6 0.4 2.3 0.7 0.5 0.2 1.5 0.4 68 7 58 255 -8.5 0.1 -8.1 -8.7 10/31/2005 18:40:00 1.6 0.5 3 0.4 1.7 0.6 3 0.4 0.7 0.4 1.9 0.4 70 7 71 255 -8.6 0.1 -8.5 -8.7 10/31/2005 18:50:00 1.9 0.4 3 1.1 2 0.4 3 1.1 0.8 0.5 2.3 0.4 70 6 77 255 -8.8 0 -8.5 -8.9 10/31/2005 19:00:00 2.9 0.5 4.2 1.9 2.9 0.5 3.8 1.9 2.1 0.5 3.4 0.4 66 9 68 255 -8.7 0 -8.5 -8.9 10/31/2005 19:10:00 2 0.3 3 1.1 2.1 0.4 3 1.1 1.1 0.4 2.3 0.4 73 7 69 255 -9 0.1 -8.7 -9.3 10/31/2005 19:20:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.9 1.6 0.4 2.6 0.7 72 8 72 255 -8.6 0 -8.5 -8.9 10/31/2005 19:30:00 2.8 0.4 3.4 1.9 2.9 0.4 3.8 1.9 1.7 0.5 2.6 0.4 88 6 88 255 -8.9 0.1 -8.7 -9.1 10/31/2005 19:40:00 2.4 0.3 3.4 1.5 2.4 0.3 3.4 1.5 1.2 0.5 2.3 0.4 94 6 86 255 -8.9 0.1 -8.7 -9.1 10/31/2005 19:50:00 2.4 0.3 3 1.9 2.4 0.3 3 1.5 1.2 0.4 2.3 0.4 97 5 109 255 -9 0.1 -8.7 -9.1 10/31/2005 20:00:00 1.7 0.4 2.6 0.4 1.7 0.5 2.6 0.4 0.9 0.4 1.9 0.4 108 17 98 255 -9.3 0 -9.1 -9.3 10/31/2005 20:10:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 135 12 147 255 -9.6 0.1 -9.3 -9.7 10/31/2005 20:20:00 1.7 0.5 2.6 0.7 1.8 0.5 2.6 0.7 1.4 0.4 2.3 0.4 139 7 143 255 -9.7 0 -9.7 -9.7 10/31/2005 20:30:00 2 0.4 3 1.1 2 0.4 3 1.1 1.7 0.6 2.6 0.4 128 15 149 255 -9.9 0 -9.7 -10.2 10/31/2005 20:40:00 2.1 0.5 2.6 1.1 2.1 0.5 3 0.7 1.4 0.4 2.3 0.4 145 14 148 255 -9.9 0 -9.7 -10.2 10/31/2005 20:50:00 2.4 0.5 3 1.5 2.4 0.5 3 1.5 1.7 0.4 2.6 0.7 158 2 154 255 -10.1 0 -10 -10.2 10/31/2005 21:00:00 1.3 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.2 0.5 2.3 0.4 152 21 160 255 -10.1 0 -10 -10.2 10/31/2005 21:10:00 1.8 0.7 3 0.7 2.2 0.3 3 1.5 1.8 0.2 2.3 1.1 186 7 189 255 -10.3 0 -10.2 -10.4 10/31/2005 21:20:00 1.4 0.5 2.6 0.4 2 0.3 2.6 1.1 1.4 0.3 2.3 0.7 179 9 196 255 -10.5 0.2 -10.2 -11 10/31/2005 21:30:00 1.3 0.4 2.3 0.4 1.7 0.3 2.3 1.1 0.7 0.3 1.5 0.4 166 3 164 255 -10.8 0 -10.6 -11 10/31/2005 21:40:00 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 151 2 158 255 -10.9 0 -10.8 -11 10/31/2005 21:50:00 0.9 0.3 1.1 0.4 1 0.2 1.5 0.7 0.6 0.3 1.1 0.4 97 0 97 255 -11 0 -11 -11.2 10/31/2005 22:00:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 97 0 97 255 -11.1 0 -11 -11.2 10/31/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.5 1.9 0.4 120 36 255 255 -11.2 0 -11 -11.4 10/31/2005 22:20:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 124 20 112 255 -11.5 0 -11.4 -11.6 10/31/2005 22:30:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 140 10 133 255 -11.5 0 -11.4 -11.6 10/31/2005 22:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 145 0 255 255 -11.6 0.1 -11.6 -11.8 10/31/2005 22:50:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 115 17 102 255 -12 0 -11.8 -12.2 10/31/2005 23:00:00 1.9 0.3 2.6 1.5 2 0.3 2.6 1.5 0.6 0.4 1.9 0.4 95 5 96 255 -12.1 0 -12 -12.2 10/31/2005 23:10:00 2.3 0.4 3 1.5 2.3 0.4 3.4 1.5 1.2 0.4 2.3 0.4 102 7 97 255 -12.1 0 -12 -12.2 10/31/2005 23:20:00 2.1 0.4 3 1.1 2.1 0.4 3 1.5 1.2 0.4 1.9 0.4 96 6 89 255 -12.1 0 -12 -12.2 10/31/2005 23:30:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.5 0.4 114 7 104 255 -12.2 0 -12 -12.4 10/31/2005 23:40:00 1.2 0.4 2.6 0.4 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 120 7 115 255 -12.2 0 -12.2 -12.2 10/31/2005 23:50:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.1 0.4 125 6 122 255 -12.3 0 -12.2 -12.6 11/01/2005 00:00:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 126 9 116 255 -12.6 0 -12.4 -12.6 11/01/2005 00:10:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 0.5 0.3 1.5 0.4 118 9 113 255 -12.6 0 -12.4 -12.6 11/01/2005 00:20:00 1.5 0.5 2.3 0.4 1.6 0.5 2.3 0.4 0.7 0.4 1.9 0.4 113 6 121 255 -12.5 0 -12.4 -12.6 11/01/2005 00:30:00 1.7 0.3 2.3 0.7 1.8 0.3 2.3 0.7 0.9 0.5 1.9 0.4 110 5 114 255 -12.7 0 -12.6 -12.6 11/01/2005 00:40:00 1.8 0.6 2.6 0.4 1.8 0.5 2.6 0.4 0.7 0.4 1.5 0.4 99 7 92 255 -12.6 0 -12.6 -12.8 11/01/2005 00:50:00 2.2 0.4 3 1.1 2.3 0.3 3 1.5 0.7 0.3 1.5 0.4 73 12 84 255 -12.8 0 -12.6 -13 11/01/2005 01:00:00 1.9 0.4 2.6 0.7 2 0.4 3 1.1 1.1 0.4 2.3 0.4 74 8 78 255 -12.6 0 -12.6 -12.6 11/01/2005 01:10:00 2.1 0.3 3 1.1 2.2 0.3 2.6 1.1 1.1 0.3 1.9 0.4 82 9 66 255 -12.6 0 -12.6 -12.6 11/01/2005 01:20:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.6 0.4 2.6 0.7 73 7 80 255 -12.6 0 -12.6 -12.6 11/01/2005 01:30:00 2.2 0.4 3 1.1 2.3 0.4 3.4 1.1 1.2 0.4 2.3 0.4 75 9 56 255 -12.4 0 -12.2 -12.6 11/01/2005 01:40:00 2 0.4 3 1.1 2.1 0.4 3 1.1 0.9 0.3 1.9 0.4 99 9 93 255 -12.4 0 -12.2 -12.6 11/01/2005 01:50:00 1.8 0.6 3.4 0.4 1.9 0.7 3.8 0.4 0.9 0.6 2.3 0.4 112 16 101 255 -12.4 0.1 -12.2 -12.6 11/01/2005 02:00:00 2.3 0.5 3 0.7 2.3 0.5 3.4 0.7 1.1 0.4 2.3 0.4 104 16 99 255 -12.7 0 -12.6 -12.8 11/01/2005 02:10:00 2.6 0.4 3.4 1.5 2.6 0.4 3.8 1.5 1.2 0.5 2.3 0.4 103 9 105 255 -12.6 0 -12.6 -12.6 11/01/2005 02:20:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 0.7 1.2 0.5 2.3 0.4 119 14 101 255 -12.9 0.1 -12.6 -13 11/01/2005 02:30:00 2.2 0.6 3.8 0.7 2.2 0.6 3.8 1.1 1.1 0.5 2.6 0.4 107 11 100 255 -12.8 0 -12.6 -13 11/01/2005 02:40:00 1.9 0.4 3 1.1 2 0.4 3.4 1.1 0.9 0.5 2.6 0.4 116 17 119 255 -12.6 0 -12.6 -12.6 11/01/2005 02:50:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 92 33 115 255 -12.6 0 -12.6 -12.8 11/01/2005 03:00:00 2 0.6 3 0.4 2 0.6 3 0.4 1.2 0.4 2.3 0.4 85 11 84 255 -12.7 0 -12.6 -12.8 11/01/2005 03:10:00 2.4 0.3 3.4 1.5 2.4 0.3 3.4 1.5 1.8 0.3 2.6 1.1 68 6 70 255 -12.6 0 -12.4 -12.6 11/01/2005 03:20:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.7 0.4 2.6 0.7 85 6 81 255 -12.4 0 -12.2 -12.6 11/01/2005 03:30:00 2.9 0.3 3.4 2.3 2.8 0.3 3.8 2.3 1.7 0.3 2.6 0.7 90 5 92 255 -12.1 0.1 -11.8 -12.2 11/01/2005 03:40:00 2.8 0.4 3.8 1.9 2.7 0.4 3.4 1.9 1.6 0.4 2.6 0.7 85 7 79 255 -11.7 0.1 -11.4 -12 11/01/2005 03:50:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.6 0.4 2.6 0.4 88 6 91 255 -11.5 0 -11.4 -11.6 11/01/2005 04:00:00 2.7 0.3 3.4 1.9 2.7 0.3 3.8 1.9 1.8 0.4 2.6 1.1 81 5 76 255 -11.6 0 -11.4 -11.6 11/01/2005 04:10:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.2 0.5 3.4 1.1 90 6 67 255 -11.6 0 -11.6 -11.8 11/01/2005 04:20:00 3 0.3 3.8 1.9 3 0.3 3.8 2.3 2 0.4 3 0.7 82 11 91 255 -11.7 0 -11.6 -11.8 11/01/2005 04:30:00 2.1 0.6 3.4 1.1 2.2 0.6 3.4 1.1 1.3 0.6 2.6 0.4 68 12 54 255 -11.4 0.1 -11.2 -11.8 11/01/2005 04:40:00 1.5 0.5 2.6 0.4 1.6 0.5 3 0.7 0.6 0.3 1.5 0.4 69 12 77 255 -11.2 0 -11 -11.4 11/01/2005 04:50:00 1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 0.4 0 0.4 0.4 48 8 51 255 -11.1 0 -11 -11.4 11/01/2005 05:00:00 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.4 0.2 1.1 0.4 56 10 52 255 -11.2 0 -11 -11.4 11/01/2005 05:10:00 1.6 0.4 2.6 0.7 1.7 0.4 2.6 0.7 0.8 0.3 1.5 0.4 79 8 66 255 -11.2 0.1 -11 -11.4 11/01/2005 05:20:00 1.9 0.4 2.6 0.7 2.1 0.3 2.6 1.1 1.1 0.3 2.3 0.4 72 8 77 255 -11.2 0 -11 -11.4 11/01/2005 05:30:00 1.9 0.4 2.6 1.1 2 0.4 2.6 1.1 1 0.4 2.3 0.4 62 6 60 255 -11.3 0 -11.2 -11.4 11/01/2005 05:40:00 2.7 0.5 3.8 1.1 2.7 0.5 3.8 1.1 1.8 0.5 3 0.7 64 8 66 255 -11.4 0 -11.2 -11.6 11/01/2005 05:50:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 1.8 0.5 3 0.4 70 6 60 255 -11.6 0 -11.4 -11.8 11/01/2005 06:00:00 2.4 0.3 3 1.5 2.5 0.3 3 1.9 1.3 0.4 2.3 0.4 68 10 64 255 -11.5 0 -11.4 -11.8 11/01/2005 06:10:00 2.1 0.5 3 0.7 2.2 0.4 3 1.1 0.9 0.5 2.3 0.4 56 6 56 255 -11.6 0.1 -11.4 -11.8 11/01/2005 06:20:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.5 0.3 1.5 0.4 17 10 41 255 -12.1 0 -11.8 -12.2 11/01/2005 06:30:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 11 0 11 255 -12.4 0.1 -12 -12.4 11/01/2005 06:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 340 47 268 255 -12.5 0 -12.2 -12.6 11/01/2005 06:50:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0 0.4 0.4 275 1 268 255 -12.7 0.2 -12.4 -13 11/01/2005 07:00:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 276 0 276 255 -13 0 -12.8 -13.2 11/01/2005 07:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 276 0 275 255 -13.1 0 -13 -13.2 11/01/2005 07:20:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.4 0.2 1.1 0.4 282 11 298 255 -13.1 0 -13 -13.2 11/01/2005 07:30:00 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 294 0 297 255 -13.4 0 -13.2 -13.6 11/01/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 322 47 255 255 -13.5 0 -13.4 -13.6 11/01/2005 07:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 40 0 40 255 -13.6 0 -13.4 -13.6 11/01/2005 08:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 35 23 295 255 -13.6 0 -13.4 -13.6 11/01/2005 08:10:00 0.9 0.5 1.9 0.4 0.9 0.6 1.9 0.4 0.5 0.3 1.5 0.4 288 15 295 255 -13.6 0 -13.4 -13.6 11/01/2005 08:20:00 1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 0.5 0.2 1.5 0.4 287 15 287 255 -13.6 0 -13.4 -13.6 11/01/2005 08:30:00 1.4 0.7 2.6 0.4 1.5 0.6 2.6 0.4 0.4 0.2 1.5 0.4 250 23 272 255 -13.3 0.2 -13 -13.8 11/01/2005 08:40:00 1.9 0.5 2.6 0.7 1.9 0.5 2.6 0.4 0.7 0.4 1.9 0.4 264 11 263 255 -12.7 0.2 -12.2 -13 11/01/2005 08:50:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.4 0 0.7 0.4 308 12 272 255 -11.9 0.2 -11.6 -12.4 11/01/2005 09:00:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 344 21 315 255 -11.4 0 -11.2 -11.6 11/01/2005 09:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 5 9 352 255 -10.9 0.2 -10.6 -11.2 11/01/2005 09:20:00 0.8 0.2 1.5 0.4 0.8 0.2 1.5 0.4 0.4 0.1 1.1 0.4 14 2 14 255 -10.5 0 -10.4 -10.6 11/01/2005 09:30:00 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 30 23 26 255 -9.9 0.3 -9.3 -10.4 11/01/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 29 255 255 -9 0.1 -8.7 -9.3 11/01/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 0 255 255 -8.7 0 -8.7 -8.9 11/01/2005 10:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 5 7 330 255 -9 0 -8.9 -9.1 11/01/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 356 0 255 255 -9 0 -8.9 -9.1 11/01/2005 10:20:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1 5 6 255 -9.2 0 -8.9 -9.3 11/01/2005 10:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 9 10 40 255 -9.3 0 -9.3 -9.3 11/01/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 36 6 255 255 -9.4 0 -9.3 -9.3 11/01/2005 10:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 25 4 26 255 -9.3 0 -9.1 -9.3 11/01/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 255 255 -9.1 0 -8.9 -9.3 11/01/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 255 255 -8.7 0.2 -8.1 -8.9 11/01/2005 11:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 353 20 12 255 -7.7 0.3 -7.2 -8.1 11/01/2005 11:30:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 13 13 11 255 -7.5 0.1 -7.2 -7.9 11/01/2005 11:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 357 15 3 255 -7.6 0 -7.4 -7.9 11/01/2005 11:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 302 5 304 255 -7.2 0.1 -7 -7.4 11/01/2005 12:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 310 16 318 255 -6.7 0.2 -6.6 -7 11/01/2005 12:10:00 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 1.1 0.5 2.3 0.4 304 15 294 255 -6.4 0.2 -5.7 -6.6 11/01/2005 12:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.9 0.4 317 10 327 255 -5.8 0.1 -5.5 -6.1 11/01/2005 12:30:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1 0.5 2.3 0.4 292 17 291 255 -6.3 0.1 -5.9 -6.6 11/01/2005 12:40:00 2.1 0.7 3.8 0.4 2 0.7 3.4 0.4 1.9 0.9 3.4 0.4 283 14 278 255 -6.6 0 -6.4 -6.8 11/01/2005 12:50:00 1.5 0.9 3.4 0.4 1.5 0.9 3.4 0.4 1.2 0.9 3 0.4 277 28 256 255 -6.6 0 -6.4 -6.8 11/01/2005 13:00:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 0.9 0.7 2.6 0.4 299 41 296 255 -6.4 0 -6.1 -6.6 11/01/2005 13:10:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 1.5 0.7 3.4 0.4 302 14 301 255 -6.4 0 -6.1 -6.6 11/01/2005 13:20:00 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 290 24 271 255 -6.5 0 -6.1 -6.6 11/01/2005 13:30:00 1.7 0.4 2.3 0.4 1.6 0.4 2.3 0.4 1.2 0.5 2.6 0.4 305 17 286 255 -6.5 0 -6.1 -6.6 11/01/2005 13:40:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.5 0.4 312 9 336 255 -6.5 0 -6.1 -6.6 11/01/2005 13:50:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 294 15 302 255 -6.5 0 -6.1 -6.6 11/01/2005 14:00:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 296 23 307 255 -6.4 0 -6.1 -6.6 11/01/2005 14:10:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 316 10 309 255 -6.2 0 -6.1 -6.4 11/01/2005 14:20:00 1.3 0.7 2.6 0.4 1.3 0.7 2.6 0.4 0.9 0.7 2.6 0.4 288 30 253 255 -6.1 0 -6.1 -6.1 11/01/2005 14:30:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 0.9 0.6 2.6 0.4 292 32 289 255 -6.2 0 -6.1 -6.4 11/01/2005 14:40:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.5 2.3 0.4 300 16 316 255 -6 0 -5.9 -6.1 11/01/2005 14:50:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 311 16 312 255 -6 0 -5.7 -5.9 11/01/2005 15:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 282 17 281 255 -6 0 -5.9 -6.1 11/01/2005 15:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 289 22 272 255 -6.1 0 -5.9 -6.1 11/01/2005 15:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 309 13 297 255 -6.1 0 -5.9 -6.4 11/01/2005 15:30:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 337 22 342 255 -6.2 0 -6.1 -6.4 11/01/2005 15:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 307 35 276 255 -6.2 0 -6.1 -6.4 11/01/2005 15:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 325 20 294 255 -6.3 0 -6.1 -6.4 11/01/2005 16:00:00 0.9 0.5 2.3 0.4 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 307 8 313 255 -6.3 0 -6.1 -6.4 11/01/2005 16:10:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 287 20 294 255 -6.4 0 -6.1 -6.6 11/01/2005 16:20:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 294 7 262 255 -6.4 0 -6.1 -6.6 11/01/2005 16:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 316 23 298 255 -6.4 0 -6.1 -6.6 11/01/2005 16:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 280 0 280 255 -6.5 0 -6.4 -6.8 11/01/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 255 255 -6.9 0.1 -6.6 -7.2 11/01/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 255 255 -7.4 0.1 -7 -7.6 11/01/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 51 255 255 -7.7 0.1 -7.6 -7.9 11/01/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 255 255 -8.1 0 -7.9 -8.3 11/01/2005 17:30:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 52 3 51 255 -8.4 0 -8.1 -8.5 11/01/2005 17:40:00 0.8 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0.1 0.7 0.4 66 4 64 255 -8.8 0 -8.5 -8.9 11/01/2005 17:50:00 0.7 0.2 1.1 0.4 0.7 0.2 1.5 0.4 0.4 0.1 0.7 0.4 78 4 73 255 -9.1 0 -8.9 -9.3 11/01/2005 18:00:00 0.7 0.2 1.1 0.4 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 81 0 81 255 -9.2 0 -9.1 -9.3 11/01/2005 18:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 109 6 81 255 -9.3 0 -9.3 -9.5 11/01/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -9.6 0 -9.5 -9.7 11/01/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -9.8 0 -9.7 -9.7 11/01/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -9.9 0 -9.7 -10 11/01/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -10.1 0.1 -9.7 -10.4 11/01/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -10.3 0 -10.2 -10.4 11/01/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -10.4 0 -10.2 -10.4 11/01/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 0 255 255 -10.5 0 -10.4 -10.8 11/01/2005 19:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 20 110 255 -10.7 0 -10.6 -11 11/01/2005 19:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 62 255 -10.9 0 -10.6 -11 11/01/2005 19:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 62 0 62 255 -10.9 0 -10.8 -11 11/01/2005 20:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 62 0 62 255 -10.9 0 -10.8 -11 11/01/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 255 255 -10.9 0 -11 -11 11/01/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 255 255 -11 0 -11 -11 11/01/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 255 255 -11.1 0 -11 -11.2 11/01/2005 20:40:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 62 0 255 255 -11.2 0 -11 -11.4 11/01/2005 20:50:00 1 0.3 1.9 0.4 1.2 0.3 1.9 0.7 0.6 0.2 1.1 0.4 82 10 95 255 -11.4 0 -11.4 -11.4 11/01/2005 21:00:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 91 0 92 255 -11.5 0 -11.4 -11.6 11/01/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 0 255 255 -11.6 0 -11.4 -11.8 11/01/2005 21:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 91 0 91 255 -11.7 0 -11.6 -11.8 11/01/2005 21:30:00 0.8 0.2 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0.1 1.1 0.4 92 0 91 255 -11.7 0 -11.6 -11.8 11/01/2005 21:40:00 0.9 0.2 1.5 0.4 1 0.2 1.5 0.4 0.4 0.1 0.7 0.4 84 3 93 255 -11.7 0 -11.6 -11.8 11/01/2005 21:50:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.4 0.1 1.1 0.4 87 2 84 255 -11.8 0 -11.8 -12 11/01/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 87 0 255 255 -12 0 -11.6 -12 11/01/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 0 255 255 -11.9 0 -11.8 -12 11/01/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 0 255 255 -12 0 -11.8 -12 11/01/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 0 255 255 -11.9 0 -11.8 -12 11/01/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 0 255 255 -11.9 0 -11.8 -11.8 11/01/2005 22:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 86 4 87 255 -11.9 0 -11.8 -12 11/01/2005 23:00:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 63 7 59 255 -11.9 0 -11.8 -12 11/01/2005 23:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 59 0 59 255 -11.7 0 -11.6 -11.8 11/01/2005 23:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 59 0 59 255 -11.6 0 -11.4 -11.8 11/01/2005 23:30:00 0.7 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 58 5 59 255 -11.6 0 -11.4 -11.8 11/01/2005 23:40:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 0.8 0.2 1.5 0.4 41 4 39 255 -11.6 0 -11.4 -11.6 11/01/2005 23:50:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 0.9 0.3 1.5 0.4 48 3 39 255 -11.6 0 -11.4 -11.8 11/02/2005 00:00:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.5 0.2 1.5 0.4 47 3 51 255 -11.5 0 -11 -11.6 11/02/2005 00:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 64 12 46 255 -11.5 0 -11.4 -11.4 11/02/2005 00:20:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 70 4 63 255 -11.4 0 -11.2 -11.4 11/02/2005 00:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 46 12 63 255 -11.4 0 -11.2 -11.4 11/02/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 255 255 -11.3 0 -11.2 -11.4 11/02/2005 00:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 43 11 52 255 -11.1 0 -11 -11.2 11/02/2005 01:00:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 52 0 52 255 -10.9 0 -10.8 -11 11/02/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 0 255 255 -10.9 0 -11 -11 11/02/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 0 255 255 -11 0 -11 -11.2 11/02/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 0 255 255 -11.2 0 -11 -11.4 11/02/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 0 255 255 -11.3 0.1 -11.2 -11.4 11/02/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 0 255 255 -11.5 0 -11.4 -11.4 11/02/2005 02:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 50 6 51 255 -11.5 0 -11.4 -11.6 11/02/2005 02:10:00 0.4 0.2 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 42 10 27 255 -11.5 0 -11.4 -11.6 11/02/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 41 8 41 255 -11.4 0 -11.2 -11.4 11/02/2005 02:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 64 8 55 255 -10.9 0.1 -10.8 -11.2 11/02/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 2 255 255 -10.9 0 -10.6 -11 11/02/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 255 255 -11.1 0 -11 -11.2 11/02/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 255 255 -11.3 0 -11 -11.4 11/02/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 0 255 255 -11.6 0 -11.4 -11.8 11/02/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 11 255 255 -11.8 0.1 -11.6 -12 11/02/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 0 255 255 -11.9 0 -11.8 -12 11/02/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 0 255 255 -11.8 0 -11.8 -11.8 11/02/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 0 255 255 -11.6 0 -11.4 -11.8 11/02/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 0 255 255 -11.4 0 -11.4 -11.4 11/02/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 0 255 255 -11.3 0 -11.2 -11.4 11/02/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 10 255 255 -11 0 -11 -11.2 11/02/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 38 10 255 255 -10.9 0 -10.8 -11 11/02/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 25 11 255 255 -10.8 0 -10.8 -11 11/02/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 255 255 -10.7 0 -10.6 -10.8 11/02/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 255 255 -10.5 0 -10.6 -10.6 11/02/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 0 255 255 -10.6 0 -10.6 -10.6 11/02/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 1 255 255 -10.6 0 -10.6 -10.8 11/02/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 10 255 255 -10.6 0 -10.6 -10.6 11/02/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 6 255 255 -10.6 0 -10.6 -10.8 11/02/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 345 5 255 255 -10.7 0 -10.6 -10.8 11/02/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 -10.7 0 -10.6 -10.8 11/02/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 -10.8 0 -10.6 -11 11/02/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 -10.9 0 -10.8 -11 11/02/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 3 255 255 -10.9 0 -11 -11 11/02/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 345 7 255 255 -10.8 0 -10.8 -11 11/02/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 349 0 255 255 -10.8 0 -10.6 -10.8 11/02/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 349 0 255 255 -10.7 0 -10.6 -10.8 11/02/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 17 255 255 -10.6 0 -10.6 -10.8 11/02/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 22 6 255 255 -10.6 0 -10.6 -10.6 11/02/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 5 255 255 -10.7 0 -10.6 -10.8 11/02/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 15 255 255 -10.8 0 -10.6 -11 11/02/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 20 255 255 -10.8 0 -10.8 -11 11/02/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 -11 0 -10.8 -11.2 11/02/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 255 255 -11.3 0.1 -11 -11.4 11/02/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 35 255 255 -11.7 0.1 -11.4 -11.8 11/02/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 13 255 255 -11.8 0 -11.6 -11.8 11/02/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 0 255 255 -11.5 0 -11.4 -11.8 11/02/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 12 255 255 -11.4 0 -11.4 -11.4 11/02/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 255 255 -11.2 0 -11 -11.4 11/02/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 255 255 -11 0 -11 -11 11/02/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 255 255 -10.9 0 -11 -11 11/02/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 20 255 255 -10.9 0 -11 -11 11/02/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 9 255 255 -10.8 0 -10.6 -11 11/02/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 22 255 255 -10.6 0.1 -10.4 -10.8 11/02/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 255 255 -10.3 0.1 -10.2 -10.4 11/02/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 255 255 -10 0 -9.7 -10.2 11/02/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 24 255 255 -9.8 0 -9.7 -10 11/02/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 255 255 -9.7 0 -9.5 -9.7 11/02/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 22 255 255 -9.5 0 -9.3 -9.7 11/02/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 16 255 255 -9.3 0 -9.1 -9.3 11/02/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 12 255 255 -9.1 0 -8.9 -9.3 11/02/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 322 12 255 255 -9 0 -8.9 -9.1 11/02/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 334 13 255 255 -8.8 0 -8.7 -8.9 11/02/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 339 15 255 255 -8.7 0 -8.5 -8.7 11/02/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 314 27 255 255 -8.7 0 -8.5 -8.7 11/02/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 312 12 255 255 -8.7 0 -8.5 -8.7 11/02/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 292 9 255 255 -8.8 0 -8.7 -8.9 11/02/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 313 10 255 255 -8.8 0 -8.7 -8.9 11/02/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 0 255 255 -8.7 0 -8.5 -8.7 11/02/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 311 6 255 255 -8.9 0 -8.7 -8.9 11/02/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 12 255 255 -9 0 -8.9 -8.9 11/02/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 20 255 255 -8.8 0 -8.7 -8.9 11/02/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 15 255 255 -8.6 0 -8.3 -8.7 11/02/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 307 11 255 255 -8.2 0.1 -8.1 -8.5 11/02/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 309 12 255 255 -8 0 -7.6 -8.1 11/02/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 323 7 255 255 -7.5 0.1 -7.2 -7.6 11/02/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 332 17 255 255 -7.4 0 -7.2 -7.6 11/02/2005 13:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 308 11 302 255 -7.4 0.2 -7 -7.9 11/02/2005 14:00:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 302 11 279 255 -8.4 0.2 -7.9 -8.7 11/02/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 304 11 255 255 -8.5 0 -8.3 -8.7 11/02/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 26 255 255 -8.2 0 -8.1 -8.5 11/02/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 16 255 255 -8.2 0 -8.1 -8.3 11/02/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 35 255 255 -8 0 -7.9 -8.1 11/02/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 22 255 255 -8 0 -7.9 -8.1 11/02/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 308 28 255 255 -8.1 0 -7.9 -8.1 11/02/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 349 16 255 255 -8.2 0 -8.1 -8.3 11/02/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 315 16 255 255 -8.3 0 -8.1 -8.5 11/02/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 331 15 255 255 -8.4 0 -8.3 -8.5 11/02/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 1 255 255 -8.4 0 -8.3 -8.5 11/02/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 4 255 255 -8.3 0 -8.1 -8.5 11/02/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 10 17 255 255 -8.2 0 -8.1 -8.3 11/02/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 11 255 255 -8.2 0 -8.1 -8.1 11/02/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 15 255 255 -8.2 0 -8.1 -8.1 11/02/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 255 255 -8.2 0 -8.1 -8.1 11/02/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 255 255 -8.2 0 -8.1 -8.5 11/02/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 255 255 -8.5 0 -8.3 -8.5 11/02/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 22 255 255 -8.6 0 -8.5 -8.7 11/02/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 255 255 -8.7 0 -8.5 -8.7 11/02/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 255 255 -8.7 0 -8.5 -8.7 11/02/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 255 255 -8.7 0 -8.5 -8.7 11/02/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 5 255 255 -8.6 0 -8.5 -8.7 11/02/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 0 255 255 -8.6 0 -8.5 -8.7 11/02/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 0 255 255 -8.6 0 -8.5 -8.7 11/02/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 0 255 255 -8.6 0 -8.5 -8.7 11/02/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 27 255 255 -8.7 0 -8.5 -8.7 11/02/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 255 255 -8.8 0 -8.7 -8.9 11/02/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 255 255 -8.9 0 -8.7 -8.9 11/02/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 189 0 255 255 -8.9 0 -8.7 -8.9 11/02/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 66 255 255 -8.9 0 -8.5 -8.9 11/02/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 331 0 255 255 -8.9 0 -8.9 -8.9 11/02/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 43 255 255 -9 0 -8.9 -9.1 11/02/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 16 255 255 -9 0 -8.9 -9.1 11/02/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 5 255 255 -9 0 -8.9 -9.1 11/02/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 13 255 255 -9.1 0 -8.9 -9.1 11/02/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 255 255 -9.2 0 -9.1 -9.3 11/02/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 1 255 255 -9.3 0 -9.3 -9.3 11/02/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 9 255 255 -9.4 0 -9.3 -9.5 11/02/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 63 13 255 255 -9.6 0 -9.3 -9.7 11/02/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 255 255 -9.7 0 -9.5 -9.7 11/02/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 19 255 255 -9.8 0 -9.7 -10 11/02/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 9 255 255 -10 0 -9.7 -10.2 11/02/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 12 255 255 -10.2 0.1 -10 -10.4 11/02/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 56 13 255 255 -10.4 0 -10.2 -10.4 11/02/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 15 255 255 -10.5 0 -10.4 -10.6 11/02/2005 21:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 23 17 255 255 -10.4 0 -10.4 -10.6 11/02/2005 21:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 70 18 255 255 -10.5 0 -10.4 -10.6 11/02/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 14 255 255 -10.5 0 -10.6 -10.6 11/02/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 255 255 -10.5 0 -10.4 -10.6 11/02/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 255 255 -10.6 0 -10.4 -10.8 11/02/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 255 255 -10.7 0 -10.6 -11 11/02/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 30 255 255 -10.9 0 -10.8 -11 11/02/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 255 255 -11.1 0.1 -11 -11.4 11/02/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 255 255 -11.4 0 -11.2 -11.4 11/02/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 255 255 -11.5 0 -11.4 -11.6 11/02/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 255 255 -11.5 0 -11.4 -11.4 11/02/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 152 36 255 255 -11.5 0 -11.4 -11.4 11/02/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 26 255 255 -11.5 0 -11.4 -11.4 11/02/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 103 18 255 255 -11.3 0 -11.2 -11.4 11/03/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 28 255 255 -11.4 0 -11.2 -11.4 11/03/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 12 255 255 -11.5 0 -11.4 -11.6 11/03/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 160 0 255 255 -11.5 0 -11.4 -11.6 11/03/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 7 255 255 -11.7 0 -11.6 -11.8 11/03/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 6 255 255 -11.8 0 -11.8 -11.8 11/03/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 255 255 -11.8 0 -11.8 -11.8 11/03/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 255 255 -11.7 0 -11.6 -11.8 11/03/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 9 255 255 -11.8 0 -11.8 -11.8 11/03/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 5 255 255 -11.9 0 -11.8 -12 11/03/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 107 15 255 255 -12 0 -11.8 -12 11/03/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 6 255 255 -12 0 -11.8 -12.2 11/03/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 103 2 255 255 -12.1 0 -12 -12.2 11/03/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 255 255 -12.1 0 -12 -12.2 11/03/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 255 255 -12.3 0 -12 -12.2 11/03/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 255 255 -12.4 0.1 -12.2 -12.6 11/03/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 255 255 -12.5 0 -12.4 -12.6 11/03/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 9 255 255 -12.6 0 -12.6 -12.6 11/03/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 6 255 255 -12.8 0 -12.6 -13 11/03/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 92 2 255 255 -12.7 0 -12.6 -13 11/03/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 255 255 -12.7 0 -12.6 -12.8 11/03/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 74 16 255 255 -12.7 0 -12.6 -12.8 11/03/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 47 255 255 -12.7 0 -12.6 -12.6 11/03/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 255 255 -12.8 0 -12.6 -12.8 11/03/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 255 255 -12.8 0 -12.6 -12.8 11/03/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 255 255 -12.7 0 -12.6 -12.8 11/03/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 255 255 -12.6 0 -12.6 -12.6 11/03/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 199 30 255 255 -12.6 0 -12.6 -12.6 11/03/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 21 255 255 -12.6 0 -12.6 -12.6 11/03/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 255 255 -12.5 0 -12.4 -12.6 11/03/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 255 255 -12.4 0 -12.2 -12.6 11/03/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 8 255 255 -12.4 0 -12.2 -12.4 11/03/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 51 255 255 -12.2 0 -12 -12.2 11/03/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 11 255 255 -12 0 -12 -12.2 11/03/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 0 255 255 -12.1 0 -12 -12.2 11/03/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 161 16 255 255 -12.2 0 -12.2 -12.2 11/03/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -12.3 0 -12.2 -12.2 11/03/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -12.3 0 -12.2 -12.2 11/03/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -12.2 0 -12.2 -12.2 11/03/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -12.1 0 -12 -12.2 11/03/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -11.9 0 -11.8 -12 11/03/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -11.7 0 -11.6 -11.8 11/03/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -11.6 0 -11.4 -11.6 11/03/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 255 255 -11.6 0 -11.4 -11.8 11/03/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 35 255 255 -11.7 0 -11.6 -11.8 11/03/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 255 255 -11.9 0 -11.8 -11.8 11/03/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 255 255 -11.9 0 -11.8 -12 11/03/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 98 255 255 -11.9 0 -11.8 -12 11/03/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 7 255 255 -11.7 0 -11.6 -11.8 11/03/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 10 255 255 -11.5 0 -11.4 -11.6 11/03/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 9 255 255 -11.5 0 -11.4 -11.6 11/03/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 8 255 255 -11.5 0 -11.4 -11.6 11/03/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 296 0 255 255 -11.6 0 -11.4 -11.8 11/03/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 17 255 255 -11.6 0 -11.6 -11.8 11/03/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 255 255 -11.6 0 -11.4 -11.6 11/03/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 11 255 255 -11.6 0 -11.4 -11.6 11/03/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 0 255 255 -11.6 0 -11.4 -11.8 11/03/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 308 12 255 255 -11.8 0 -11.6 -11.8 11/03/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 255 255 -11.8 0 -11.8 -11.8 11/03/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 15 255 255 -11.6 0 -11.4 -11.8 11/03/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 20 255 255 -11.6 0 -11.4 -11.8 11/03/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 10 255 255 -11.8 0 -11.6 -11.8 11/03/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 12 255 255 -11.8 0 -11.8 -11.8 11/03/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 255 255 -11.3 0.3 -11 -11.8 11/03/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 158 0 255 255 -11 0 -11 -11.2 11/03/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 35 255 255 -10.9 0 -10.8 -11 11/03/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 22 255 255 -11 0 -11 -11 11/03/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 27 255 255 -11 0 -11 -11.2 11/03/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 345 9 255 255 -10.9 0 -10.8 -11 11/03/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 -10.8 0 -10.6 -11 11/03/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 -10.9 0 -10.8 -11 11/03/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 -10.9 0 -10.8 -11 11/03/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 -10.8 0 -10.6 -11 11/03/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 350 0 255 255 -10.7 0 -10.6 -10.8 11/03/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 8 255 255 -10.2 0.2 -9.7 -10.6 11/03/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 255 255 -9.8 0 -9.5 -10.2 11/03/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 28 255 255 -10.1 0 -10 -10.2 11/03/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 258 10 255 255 -10.2 0.1 -10 -10.4 11/03/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 308 17 255 255 -10.2 0 -10 -10.2 11/03/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 292 10 255 255 -10.1 0 -10 -10.2 11/03/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 316 7 255 255 -10 0 -9.7 -10.2 11/03/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 292 15 255 255 -10 0.3 -9.5 -10.4 11/03/2005 13:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 218 29 255 255 -10.3 0 -10.2 -10.4 11/03/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 22 255 255 -10 0.1 -9.7 -10.2 11/03/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 206 45 255 255 -9.7 0.1 -9.5 -9.7 11/03/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 158 64 255 255 -9.4 0.1 -9.3 -9.7 11/03/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 22 255 255 -9.2 0 -9.1 -9.3 11/03/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 209 38 255 255 -9.1 0 -8.9 -9.3 11/03/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 29 255 255 -8.9 0 -8.7 -8.9 11/03/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 235 38 255 255 -8.9 0 -8.7 -8.9 11/03/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 194 28 255 255 -8.8 0 -8.7 -8.9 11/03/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 217 22 255 255 -8.8 0 -8.7 -8.9 11/03/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 187 9 255 255 -9 0 -8.7 -9.1 11/03/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 187 0 255 255 -8.9 0 -8.7 -8.9 11/03/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 51 255 255 -8.7 0 -8.7 -8.9 11/03/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -8.7 0 -8.7 -8.7 11/03/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -8.7 0 -8.7 -8.7 11/03/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -8.7 0 -8.7 -8.9 11/03/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -8.9 0 -8.7 -9.1 11/03/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -9.2 0 -8.9 -9.3 11/03/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -9.6 0.1 -9.3 -9.7 11/03/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -10.1 0.1 -9.7 -10.4 11/03/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -10.5 0.1 -10.4 -10.8 11/03/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -11 0.1 -10.6 -11.4 11/03/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 255 255 -11.4 0 -11.2 -11.4 11/03/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 68 24 255 255 -11.6 0 -11.4 -11.8 11/03/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 0 255 255 -11.9 0 -11.8 -12 11/03/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 0 255 255 -12 0 -11.8 -12.2 11/03/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 69 255 255 -12.2 0.1 -12 -12.4 11/03/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 255 255 -12.5 0 -12.2 -12.6 11/03/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 255 255 -12.7 0.1 -12.6 -13 11/03/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 255 255 -13 0 -12.8 -13.2 11/03/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 35 255 255 -13.1 0 -13 -13.2 11/03/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 35 255 255 -13.4 0.1 -13.2 -13.6 11/03/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 290 32 255 255 -13.7 0 -13.6 -13.6 11/03/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 260 0 255 255 -13.7 0 -13.6 -13.8 11/03/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 4 255 255 -13.9 0 -13.8 -14 11/03/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 253 1 255 255 -14.1 0 -14 -14.2 11/03/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 284 38 255 255 -14.3 0 -14 -14.6 11/03/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 215 20 255 255 -14.4 0 -14.2 -14.6 11/03/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 45 255 255 -14.4 0 -14.2 -14.6 11/03/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 33 255 255 -14.7 0.1 -14.4 -14.8 11/03/2005 20:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 13 69 255 -15 0.1 -14.8 -15.1 11/03/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 7 255 255 -15 0 -14.8 -15.1 11/03/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 13 255 255 -15 0 -14.8 -15.1 11/03/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 5 255 255 -15.1 0 -15 -15.1 11/03/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 9 255 255 -15.1 0 -15 -15.1 11/03/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 5 255 255 -15.1 0 -15 -15.3 11/03/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 45 255 255 -15 0.1 -14.8 -15.3 11/03/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 45 255 255 -14.8 0.1 -14.6 -15 11/03/2005 21:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 25 33 102 255 -15 0 -15 -15 11/03/2005 21:40:00 1.2 0.9 3.4 0.4 1.8 1.1 4.6 0.4 0.7 0.4 1.9 0.4 110 15 131 255 -14.9 0.1 -14.6 -15 11/03/2005 21:50:00 2.3 1.1 6.1 0.4 2.5 1.1 6.1 0.4 0.8 0.6 2.6 0.4 91 33 121 255 -14.6 0 -14.4 -14.8 11/03/2005 22:00:00 3.4 0.9 5.7 1.5 3.6 0.9 5.7 1.5 1.5 0.7 3 0.4 121 18 134 255 -14 0.5 -13.4 -14.6 11/03/2005 22:10:00 4.3 1 7.2 2.3 4.4 1.1 7.2 2.3 2.7 0.8 5.7 0.7 130 16 122 255 -10.9 1.4 -8.9 -13.4 11/03/2005 22:20:00 3.4 1.5 7.2 0.4 3.5 1.5 7.2 0.4 2.2 1.3 6.1 0.4 137 32 140 255 -9.1 0.4 -8.7 -10.4 11/03/2005 22:30:00 2.8 1 5.3 0.4 2.8 1 5.7 0.4 2 0.9 4.9 0.4 134 17 144 255 -10.9 0.2 -10.2 -11.2 11/03/2005 22:40:00 2 0.5 3.8 0.4 2.1 0.5 3.4 0.4 1.3 0.5 2.6 0.4 114 26 117 255 -11.3 0.2 -11 -11.4 11/03/2005 22:50:00 2.3 1.1 6.1 0.4 2.5 1.1 6.1 0.4 1.6 0.9 4.9 0.4 98 22 106 255 -10.5 0.5 -9.7 -11.4 11/03/2005 23:00:00 3.2 1 6.5 1.1 3.3 1 6.8 0.7 2.4 0.8 4.9 0.4 103 22 94 255 -9.8 0.2 -9.3 -10.2 11/03/2005 23:10:00 3.6 1.1 6.8 1.1 3.7 1.1 7.2 1.5 2.6 0.9 4.6 0.7 95 17 106 255 -9.6 0.1 -9.3 -9.7 11/03/2005 23:20:00 3.4 1.3 7.2 0.7 3.4 1.2 6.8 1.1 2.1 1.2 5.7 0.4 96 21 110 255 -9.6 0 -9.3 -9.7 11/03/2005 23:30:00 1.9 0.8 3.8 0.4 2 0.8 3.8 0.4 1.1 0.6 3 0.4 76 17 77 255 -10 0.2 -9.7 -10.4 11/03/2005 23:40:00 3.4 1.7 8.4 0.4 3.4 1.6 8 0.4 2.6 1.4 6.8 0.4 97 41 78 255 -9.9 0.4 -9.3 -10.4 11/03/2005 23:50:00 1.9 0.9 3.8 0.4 1.9 0.8 3.8 0.4 1.1 0.6 2.6 0.4 106 29 101 255 -9.8 0.3 -9.3 -10.4 11/04/2005 00:00:00 4 1.8 9.5 0.4 4 1.8 9.1 0.4 3 1.5 7.2 0.4 108 29 127 255 -9.6 0.6 -8.5 -10.4 11/04/2005 00:10:00 2.4 1.5 7.2 0.4 2.5 1.5 7.2 0.4 2 1.3 6.8 0.4 96 24 110 255 -8.7 0.2 -8.5 -9.1 11/04/2005 00:20:00 1 0.9 4.2 0.4 1.1 0.9 4.2 0.4 0.7 0.6 2.6 0.4 123 41 152 255 -9.7 0.3 -8.9 -10.2 11/04/2005 00:30:00 3.2 1 6.8 1.1 3.3 1 6.5 1.5 2.6 1.1 4.9 0.4 113 29 158 255 -9.7 0.3 -9.3 -10.4 11/04/2005 00:40:00 1.6 0.8 3.8 0.4 1.7 0.7 3.4 0.4 1.2 0.7 3 0.4 82 28 74 255 -9.6 0.2 -9.3 -10.2 11/04/2005 00:50:00 2.2 1.3 6.8 0.4 2.3 1.3 6.8 0.4 1.8 1.2 6.5 0.4 57 51 93 255 -9.8 0.1 -9.5 -10.2 11/04/2005 01:00:00 1.7 1 3.8 0.4 1.8 1 4.2 0.4 1.1 0.8 3 0.4 71 35 139 255 -10.4 0 -10.2 -10.6 11/04/2005 01:10:00 3.3 2 9.9 0.4 3.5 1.9 9.5 0.4 2.3 1.7 9.1 0.4 71 36 93 255 -10.2 0.4 -9.7 -11 11/04/2005 01:20:00 7.6 2.3 13.3 2.6 7.6 2.4 13 2.6 6.3 2.3 11.8 1.9 97 22 88 255 -8.5 0.9 -7.2 -10.2 11/04/2005 01:30:00 8.5 2.4 14.9 2.3 8.5 2.4 14.5 3 7.2 2.1 14.1 2.6 104 23 85 255 -7.2 0.1 -7 -7.2 11/04/2005 01:40:00 8.5 2.5 15.6 3.4 8.5 2.5 15.3 3.4 7.3 2.4 13 1.1 103 19 110 255 -7.1 0 -6.8 -7 11/04/2005 01:50:00 8.8 2.6 17.9 1.9 8.7 2.6 17.9 2.3 7.5 2.3 16.1 2.6 104 22 89 255 -7.1 0 -6.8 -7 11/04/2005 02:00:00 8 2.5 16.8 2.6 7.9 2.5 16.1 2.6 7.1 2.2 16.1 3 110 22 110 255 -6.9 0 -6.8 -7 11/04/2005 02:10:00 7 2.1 13.3 3 7.1 2 12.6 2.6 5.7 1.9 12.2 1.9 114 24 129 255 -7.1 0 -6.8 -7 11/04/2005 02:20:00 6.5 1.9 13.3 2.6 6.5 1.9 13.3 2.6 5.7 1.8 12.6 1.9 118 21 109 255 -7.1 0 -7 -7.2 11/04/2005 02:30:00 7.7 2.1 13.7 3 7.7 2.1 15.3 3 6.7 2 12.2 2.3 112 20 104 255 -7.1 0 -6.8 -7 11/04/2005 02:40:00 6.4 1.6 11.5 1.5 6.4 1.7 10.7 2.3 5.7 1.5 9.9 1.5 109 21 120 255 -7.1 0 -6.8 -7 11/04/2005 02:50:00 7.8 2.3 13 1.1 7.7 2.3 12.6 1.9 6.7 2.2 13.3 1.5 110 20 115 255 -7.1 0 -6.8 -7 11/04/2005 03:00:00 7.5 2.1 13 3 7.5 2 12.6 2.6 6.6 1.9 13 2.6 117 22 118 255 -6.9 0 -6.8 -7 11/04/2005 03:10:00 6 2.2 12.2 0.7 6 2.2 11.8 0.7 5.3 2 11.8 1.5 124 27 108 255 -7.1 0 -6.8 -7 11/04/2005 03:20:00 5.9 1.8 10.7 1.5 5.9 1.9 11.1 1.9 5.2 1.7 9.9 1.1 124 21 113 255 -7.1 0 -6.8 -7 11/04/2005 03:30:00 6.4 2.1 13 1.9 6.3 2 12.2 2.3 5.7 1.9 11.5 1.1 126 22 146 255 -7 0 -6.8 -7 11/04/2005 03:40:00 6.4 1.7 11.1 2.3 6.4 1.7 11.1 2.6 5.6 1.6 10.3 1.9 120 20 99 255 -7.1 0 -7 -7.2 11/04/2005 03:50:00 6.3 1.7 10.7 1.9 6.3 1.7 11.8 2.3 5.6 1.7 9.5 1.5 119 23 143 255 -7.1 0 -7 -7 11/04/2005 04:00:00 6 1.6 9.9 1.1 5.9 1.6 10.3 0.7 5.2 1.5 9.1 1.9 119 24 91 255 -7.1 0 -7 -7.2 11/04/2005 04:10:00 7 2 11.8 1.5 6.9 2 12.2 1.5 6.1 2 11.5 2.3 112 19 127 255 -7.1 0 -7 -7.2 11/04/2005 04:20:00 7.3 2.1 12.2 1.1 7.2 2.1 13 2.3 6.4 1.6 10.7 2.3 114 19 100 255 -7.1 0 -7 -7.2 11/04/2005 04:30:00 6.9 2.1 12.2 2.6 7 2 11.8 2.3 6.1 2.2 13 1.1 114 20 108 255 -7.3 0.1 -7 -7.4 11/04/2005 04:40:00 6.5 1.8 11.5 2.3 6.5 1.8 11.8 2.6 5.8 1.7 10.3 1.9 110 18 118 255 -7.4 0 -7.2 -7.4 11/04/2005 04:50:00 8.1 2.2 14.5 1.5 8 2.2 14.1 3 6.9 2.2 12.6 1.1 110 20 110 255 -7.5 0 -7.2 -7.6 11/04/2005 05:00:00 7.4 1.8 12.6 2.6 7.5 1.8 12.2 2.6 6.2 1.8 11.1 2.3 109 17 124 255 -7.5 0 -7.2 -7.6 11/04/2005 05:10:00 7.3 1.5 12.2 2.3 7.2 1.5 11.1 3.4 6 1.7 10.3 2.3 110 21 119 255 -7.6 0 -7.6 -7.6 11/04/2005 05:20:00 7.2 1.9 11.8 3 7.1 1.9 11.8 2.6 6.2 1.9 10.7 1.9 115 19 110 255 -7.6 0 -7.6 -7.6 11/04/2005 05:30:00 6.8 1.9 12.6 2.3 6.8 1.8 12.6 3 6 1.8 12.2 2.3 115 21 102 255 -7.9 0 -7.6 -7.9 11/04/2005 05:40:00 7.4 2 13.3 3 7.4 2 13 2.6 6.6 1.8 11.5 2.6 113 18 99 255 -7.9 0 -7.9 -8.1 11/04/2005 05:50:00 6.7 1.9 13 3 6.6 1.9 12.2 3 5.9 1.8 11.8 1.9 116 21 126 255 -8 0 -7.9 -8.1 11/04/2005 06:00:00 7.8 2.1 13.7 2.6 7.8 2.1 13.3 2.6 6.9 1.8 11.5 2.3 110 18 94 255 -7.9 0 -7.6 -7.9 11/04/2005 06:10:00 7.5 1.8 11.8 3 7.5 1.8 11.5 3.4 6.5 1.7 12.2 1.9 107 17 129 255 -7.9 0 -7.6 -8.1 11/04/2005 06:20:00 7.6 2.2 14.5 2.6 7.6 2 14.9 2.3 6.7 1.9 13.3 2.3 112 20 80 255 -8 0 -7.9 -8.1 11/04/2005 06:30:00 7.6 2.3 14.1 1.9 7.6 2.2 13.3 2.6 6.5 2.1 13.3 1.9 108 21 98 255 -8.1 0 -8.1 -8.1 11/04/2005 06:40:00 8.1 2.2 14.9 3.8 8.1 2.2 13.7 3.8 7 2.2 13.3 3 104 18 110 255 -8.1 0 -8.1 -8.1 11/04/2005 06:50:00 8.3 2.6 16.4 3 8.2 2.4 15.6 3.4 7.2 2.3 16.1 3 102 18 92 255 -8.1 0 -7.9 -8.1 11/04/2005 07:00:00 7 1.8 12.6 3.8 7 1.8 13 3.4 5.9 1.8 11.5 2.3 102 19 94 255 -8.1 0 -7.9 -8.1 11/04/2005 07:10:00 7.6 2.2 13.3 3 7.5 2.1 13 3 6.6 2.1 11.8 2.3 98 22 93 255 -8.2 0 -8.1 -8.3 11/04/2005 07:20:00 8.4 2.3 14.1 3 8.3 2.2 14.1 3 6.7 2.3 12.2 1.9 106 22 134 255 -8.1 0 -7.9 -8.1 11/04/2005 07:30:00 7.1 2.2 14.5 3 7.1 2.1 14.9 3 6.2 2.2 13.3 1.9 100 22 97 255 -8.3 0 -8.1 -8.3 11/04/2005 07:40:00 8.7 2.5 16.1 3 8.7 2.4 14.5 2.6 7.3 2.3 14.1 2.3 103 18 134 255 -8.2 0 -8.1 -8.3 11/04/2005 07:50:00 7.6 2.5 14.9 1.9 7.7 2.3 14.5 2.3 6.6 2.3 12.6 1.9 100 20 93 255 -8.2 0 -8.1 -8.3 11/04/2005 08:00:00 8.9 2.8 14.5 2.6 9 2.7 14.5 2.6 7.8 2.6 13.7 1.9 104 19 104 255 -8.2 0 -8.1 -8.3 11/04/2005 08:10:00 10.1 2.8 19.1 4.2 10 2.7 18.7 3.8 8.7 2.7 16.8 2.6 105 20 110 255 -8.2 0 -8.1 -8.3 11/04/2005 08:20:00 10.1 2.6 16.4 1.9 10 2.5 16.4 3 8.3 2.5 15.3 1.5 104 23 129 255 -8.2 0 -8.1 -8.3 11/04/2005 08:30:00 9.4 2.6 15.6 3 9.4 2.5 15.6 3.8 8.2 2.4 15.6 3.4 108 20 98 255 -8.2 0 -8.1 -8.3 11/04/2005 08:40:00 8.9 2.8 15.6 2.6 8.8 2.7 15.3 3 7.7 2.6 14.5 2.6 103 22 95 255 -8.3 0 -8.1 -8.5 11/04/2005 08:50:00 10.4 2.9 17.2 3 10.3 2.9 17.2 3 9.3 2.7 15.3 3 101 19 93 255 -8 0 -7.9 -8.1 11/04/2005 09:00:00 8.2 2.2 13.7 2.6 8.2 2.2 14.9 3 7.4 2.1 13.3 3 106 22 75 255 -8.1 0 -7.9 -8.1 11/04/2005 09:10:00 8.8 2.5 16.8 3 8.7 2.5 16.8 2.6 7.5 2.3 14.9 1.9 103 20 109 255 -8 0 -7.6 -8.1 11/04/2005 09:20:00 8.8 2.6 15.6 1.9 8.8 2.5 16.1 2.6 7.8 2.4 13.7 2.6 103 20 106 255 -7.6 0 -7.4 -7.9 11/04/2005 09:30:00 8.9 2.3 16.4 4.6 8.9 2.2 17.2 3.8 7.7 2.2 14.1 3 104 21 92 255 -7.6 0 -7.4 -7.6 11/04/2005 09:40:00 8.9 2.4 15.6 3.8 8.9 2.4 14.9 3.4 7.8 2.4 14.1 2.6 105 19 113 255 -7.6 0 -7.4 -7.6 11/04/2005 09:50:00 9.1 2.2 14.9 3.8 9 2.2 14.9 3 7.9 1.9 13.3 3.8 103 16 109 255 -7.6 0 -7.4 -7.9 11/04/2005 10:00:00 8.4 2.4 14.1 2.3 8.3 2.4 14.1 2.3 7.4 2.1 13.7 3 105 21 105 255 -7.7 0 -7.6 -7.9 11/04/2005 10:10:00 8.8 2.2 16.1 4.2 8.8 2.2 15.3 4.6 7.8 2.1 13.7 3.4 105 19 115 255 -7.5 0 -7.4 -7.6 11/04/2005 10:20:00 9.6 2.6 16.4 3.4 9.7 2.4 16.4 4.9 8.2 2.5 14.9 3.4 103 18 90 255 -7.4 0 -7.2 -7.6 11/04/2005 10:30:00 9.3 2.2 14.1 3.4 9.2 2.2 14.5 2.6 8.2 2.2 14.5 3.4 104 19 85 255 -7.5 0 -7.4 -7.6 11/04/2005 10:40:00 9.5 3.3 18.7 1.1 9.5 3.2 18.3 1.5 8.4 3.1 16.8 1.5 104 17 110 255 -7.3 0 -7.2 -7.4 11/04/2005 10:50:00 9.2 2.4 15.3 4.9 9.1 2.3 15.3 5.3 8.1 2.3 15.6 3.4 105 22 93 255 -7.3 0 -7.2 -7.4 11/04/2005 11:00:00 10.1 2.4 18.7 4.2 10.1 2.4 19.1 3.8 8.7 2.3 14.5 2.6 107 20 99 255 -7.3 0 -7.2 -7.4 11/04/2005 11:10:00 10.1 2.5 17.2 4.6 10 2.5 17.2 3.8 8.7 2.6 16.1 3 105 17 115 255 -7.1 0 -6.8 -7.2 11/04/2005 11:20:00 9.1 2.4 14.9 3.4 9 2.3 14.9 3.4 8.1 2.5 16.4 3.4 103 20 90 255 -7 0 -6.8 -7 11/04/2005 11:30:00 9.7 2.7 17.9 2.6 9.7 2.7 19.1 3 8.4 2.5 15.6 1.9 104 22 89 255 -6.9 0 -6.8 -7 11/04/2005 11:40:00 9.5 2.8 15.6 3.8 9.5 2.7 16.1 4.2 8.3 2.7 14.5 2.6 105 18 111 255 -6.9 0 -6.8 -7 11/04/2005 11:50:00 10.3 3.1 19.1 3.4 10.2 3.1 18.3 3.8 9.1 3.1 16.8 2.6 101 22 84 255 -6.8 0 -6.6 -7 11/04/2005 12:00:00 9.6 2.9 16.4 2.6 9.6 2.8 16.1 3 8.5 2.8 14.5 1.5 103 21 88 255 -6.5 0 -6.1 -6.6 11/04/2005 12:10:00 10.5 3.1 17.9 3.8 10.5 2.9 18.3 4.2 9.3 2.7 17.9 4.2 103 17 99 255 -6.2 0 -6.1 -6.4 11/04/2005 12:20:00 11 2.7 17.6 5.3 11 2.7 16.8 5.3 9.5 2.6 16.4 4.2 101 17 99 255 -6 0 -5.9 -6.1 11/04/2005 12:30:00 9.5 2.6 20.2 3 9.4 2.6 20.6 2.3 8.3 2.4 16.4 2.6 106 18 104 255 -6.1 0 -5.9 -6.1 11/04/2005 12:40:00 8.6 2.5 14.9 2.6 8.5 2.5 14.5 3 7.3 2.3 13 2.6 107 20 107 255 -6 0 -5.9 -6.1 11/04/2005 12:50:00 9 2.6 17.2 3.4 9 2.6 17.6 3.4 8.1 2.5 16.4 1.9 102 22 104 255 -6 0 -5.9 -5.9 11/04/2005 13:00:00 8.2 2.5 16.4 3 8.2 2.5 16.1 2.6 7.3 2.6 15.6 0.4 104 19 106 255 -5.9 0 -5.7 -5.9 11/04/2005 13:10:00 8.5 2 13.3 3 8.5 1.9 13 3 7.7 1.8 12.6 2.6 105 17 143 255 -5.8 0.1 -5.7 -5.9 11/04/2005 13:20:00 8 2.5 15.6 3 7.9 2.4 14.9 3 6.7 2.3 14.9 2.3 107 22 85 255 -5.6 0 -5.5 -5.7 11/04/2005 13:30:00 8.6 2.2 15.3 3.8 8.6 2.1 14.9 4.2 7.7 2.2 13.7 2.6 104 17 138 255 -5.4 0 -5.5 -5.7 11/04/2005 13:40:00 9.2 2.1 13.7 4.6 9.1 2.1 13.7 3.8 8.1 1.9 12.6 3.4 108 17 122 255 -5.6 0 -5.5 -5.7 11/04/2005 13:50:00 8.2 2.1 13.3 1.5 8.2 2.1 14.1 3 7.1 1.9 12.6 1.9 109 18 86 255 -5.4 0 -5.5 -5.5 11/04/2005 14:00:00 7.3 2.2 13 2.6 7.3 2.1 12.6 3 6.6 2.1 12.6 2.6 106 17 118 255 -5.4 0 -5.5 -5.5 11/04/2005 14:10:00 8.1 2.1 13.3 1.1 8.1 2 13.7 1.9 7 1.8 13.3 1.5 107 20 149 255 -5.6 0.1 -5.5 -5.7 11/04/2005 14:20:00 7.8 2.6 16.4 2.6 7.8 2.6 14.9 2.6 7 2.4 12.6 1.9 110 24 92 255 -5.6 0 -5.5 -5.7 11/04/2005 14:30:00 6.9 2.1 11.8 1.9 7 2 11.8 2.6 6.3 2 11.8 1.9 104 23 129 255 -5.6 0 -5.5 -5.7 11/04/2005 14:40:00 7.8 2.5 16.1 1.5 7.8 2.4 15.6 2.3 6.8 2.1 13.7 2.6 112 21 95 255 -5.8 0 -5.5 -5.9 11/04/2005 14:50:00 8.1 2.5 15.3 3 8.1 2.5 15.6 1.9 7.1 2.1 13.3 2.6 109 21 132 255 -5.9 0 -5.7 -5.9 11/04/2005 15:00:00 8.4 2.5 16.1 2.6 8.4 2.4 16.4 2.3 7.8 2.2 13.3 3.8 116 20 86 255 -6 0 -5.9 -6.1 11/04/2005 15:10:00 7.1 2.1 13 2.6 7.1 2.1 13.3 2.3 6.3 1.9 13 1.9 114 24 119 255 -6.3 0.1 -6.1 -6.6 11/04/2005 15:20:00 6.7 2.2 12.6 2.3 6.7 2.1 12.6 2.6 5.9 1.7 11.1 2.3 113 22 105 255 -6.5 0 -6.4 -6.6 11/04/2005 15:30:00 8.8 2.7 15.3 2.6 8.7 2.7 14.9 2.6 7.3 2.4 13 2.3 114 22 92 255 -6.5 0 -6.4 -6.6 11/04/2005 15:40:00 7.5 2.6 13.3 2.3 7.5 2.5 13.3 1.9 6.4 2.2 12.2 1.9 119 22 111 255 -6.5 0 -6.6 -6.6 11/04/2005 15:50:00 6.2 2 11.8 2.3 6.3 1.9 12.2 2.3 5.7 2.1 12.6 1.9 119 21 92 255 -6.7 0 -6.6 -6.8 11/04/2005 16:00:00 6.9 1.7 12.2 2.6 6.9 1.7 11.8 3 6.2 1.7 10.7 2.3 123 22 108 255 -6.9 0.1 -6.6 -7 11/04/2005 16:10:00 5.9 1.9 10.7 1.9 5.9 1.8 10.7 1.9 5.1 1.7 10.3 0.7 123 24 90 255 -7.1 0 -6.8 -7.2 11/04/2005 16:20:00 7.1 2.4 12.6 1.5 7.1 2.3 13 1.5 6.5 2.1 11.8 1.9 120 22 84 255 -7.1 0 -7 -7.2 11/04/2005 16:30:00 7.9 2.3 14.9 3.4 7.8 2.2 15.3 3 6.6 2.2 13 2.6 117 21 101 255 -7.2 0 -7 -7.2 11/04/2005 16:40:00 6.5 2.1 13 2.3 6.5 2.1 12.6 3 5.7 1.9 11.5 1.5 113 22 118 255 -7.4 0 -7.2 -7.4 11/04/2005 16:50:00 6.5 2 12.2 1.5 6.5 1.9 11.5 1.5 5.8 1.8 10.7 2.6 112 23 122 255 -7.5 0 -7.2 -7.6 11/04/2005 17:00:00 7.5 1.9 13.7 2.6 7.5 1.8 13 2.3 6.4 1.7 11.8 2.6 115 22 102 255 -7.5 0 -7.2 -7.6 11/04/2005 17:10:00 7.8 2.6 15.6 2.6 7.8 2.4 14.5 2.6 6.6 2.2 13.3 1.9 113 23 98 255 -7.6 0 -7.6 -7.6 11/04/2005 17:20:00 8.2 2.5 16.1 3 8.2 2.4 16.1 3 7 2.2 14.1 2.6 118 23 101 255 -7.7 0 -7.6 -7.9 11/04/2005 17:30:00 7 2.3 13.7 2.6 7.2 2.2 13.3 3 6.1 2.1 11.5 1.1 119 23 85 255 -7.9 0 -7.6 -8.1 11/04/2005 17:40:00 7.3 2.1 12.2 3 7.4 2.1 13 3 6.3 1.8 11.5 1.9 121 22 134 255 -8 0 -7.9 -8.1 11/04/2005 17:50:00 7.2 2.1 16.1 3 7.1 2 15.3 2.6 6 1.7 12.2 2.3 124 21 110 255 -8.1 0 -7.9 -8.1 11/04/2005 18:00:00 7.6 2.1 12.6 2.6 7.6 2.1 13.3 2.6 6.8 2.2 12.2 2.3 123 22 116 255 -8.2 0 -8.1 -8.1 11/04/2005 18:10:00 7.6 2.1 13.7 3 7.6 2 13.3 3 6.7 2 11.8 2.3 128 22 121 255 -8.2 0 -8.1 -8.3 11/04/2005 18:20:00 6.8 2.4 12.6 1.9 6.8 2.3 12.6 1.5 5.9 2 11.5 1.9 127 23 112 255 -8.3 0 -8.1 -8.5 11/04/2005 18:30:00 6.9 2.6 13 1.5 6.9 2.5 12.6 1.9 6.1 2.4 13 2.3 122 23 138 255 -8.3 0 -8.1 -8.5 11/04/2005 18:40:00 7 2.3 12.2 2.3 7.1 2.2 12.2 1.9 6.4 1.9 11.8 2.3 120 22 126 255 -8.3 0 -8.1 -8.5 11/04/2005 18:50:00 8.5 3.1 16.8 1.9 8.4 2.9 16.4 1.9 7.3 2.7 16.1 2.3 118 22 99 255 -8.3 0 -8.1 -8.5 11/04/2005 19:00:00 8.9 2.7 17.9 4.6 8.9 2.6 18.7 4.2 7.5 2.3 15.6 3.4 120 22 117 255 -8.3 0 -8.1 -8.5 11/04/2005 19:10:00 7.3 2.2 14.9 2.6 7.3 2.2 13.7 3 6.5 2.4 13.7 2.3 123 22 112 255 -8.5 0.1 -8.3 -8.7 11/04/2005 19:20:00 8.4 2.9 16.8 2.3 8.4 2.9 16.4 3 7.6 2.6 16.4 3.4 122 22 118 255 -8.6 0 -8.5 -8.7 11/04/2005 19:30:00 7.7 2.5 16.1 2.3 7.7 2.4 15.6 3 6.7 2.3 13.3 2.6 122 24 88 255 -8.6 0 -8.5 -8.7 11/04/2005 19:40:00 8.5 2.9 17.2 3 8.4 2.8 16.8 3 7.3 2.7 15.6 1.9 119 22 119 255 -8.6 0 -8.5 -8.7 11/04/2005 19:50:00 7.6 2.2 14.9 3.4 7.6 2 14.9 3.8 6.6 1.8 11.8 1.9 125 22 97 255 -8.7 0 -8.5 -8.7 11/04/2005 20:00:00 7 1.9 12.6 3.4 7.1 1.8 12.6 3 5.9 1.8 11.5 1.5 131 22 164 255 -8.7 0 -8.5 -8.7 11/04/2005 20:10:00 7.2 2.2 12.2 2.6 7.2 2.1 13 3 6.3 1.9 12.6 2.6 138 22 130 255 -8.7 0 -8.7 -8.9 11/04/2005 20:20:00 6.8 2.2 12.2 1.5 6.8 2.2 11.8 1.9 6 1.9 10.7 1.9 130 23 119 255 -8.8 0 -8.7 -8.9 11/04/2005 20:30:00 7.9 1.8 12.6 3.8 7.9 1.7 12.6 3.8 6.7 1.8 11.5 3 127 21 115 255 -8.9 0 -8.7 -8.9 11/04/2005 20:40:00 7.7 2.6 14.5 1.5 7.8 2.6 14.1 1.9 6.9 2.3 13 0.7 124 22 89 255 -8.9 0 -8.7 -8.9 11/04/2005 20:50:00 8.2 2.6 15.6 1.9 8.1 2.6 14.9 2.3 7.3 2.4 13 2.6 124 21 136 255 -8.8 0 -8.7 -8.9 11/04/2005 21:00:00 8.4 2.4 15.6 2.6 8.3 2.4 15.6 3 7 2.2 15.6 1.9 123 22 125 255 -8.8 0 -8.7 -8.9 11/04/2005 21:10:00 8.3 2.4 15.3 3 8.2 2.3 15.3 3 6.9 2.2 13 2.3 120 22 139 255 -9 0 -8.9 -9.1 11/04/2005 21:20:00 9.2 2.8 17.9 3.4 9.3 2.8 17.6 3 8 2.6 15.3 2.3 124 21 142 255 -9 0 -8.9 -9.1 11/04/2005 21:30:00 9.7 2.7 17.2 3.8 9.6 2.7 16.4 4.6 8.2 2.6 15.6 3 121 22 104 255 -9 0 -8.9 -9.1 11/04/2005 21:40:00 9.6 2.9 17.9 3 9.6 2.9 18.3 2.6 8.5 2.9 17.2 3.4 124 22 119 255 -9 0 -8.9 -9.1 11/04/2005 21:50:00 11.2 2.9 19.9 4.9 11 2.8 19.9 4.2 9.7 2.7 18.7 3.4 119 21 115 255 -8.9 0 -8.7 -8.9 11/04/2005 22:00:00 10.2 3.3 19.1 2.6 10.1 3.3 18.3 1.5 8.7 3.1 17.9 1.9 118 22 115 255 -8.8 0 -8.7 -8.9 11/04/2005 22:10:00 10.3 3.3 21 3.4 10.3 3.3 20.2 3.4 8.6 2.8 17.9 3 115 22 80 255 -8.8 0 -8.7 -8.9 11/04/2005 22:20:00 9.5 3.1 17.9 3.4 9.4 3.1 17.6 3.8 8.3 2.8 15.3 3 117 22 125 255 -9 0 -8.7 -8.9 11/04/2005 22:30:00 10.9 2.8 18.7 3.8 10.8 2.8 17.6 3.8 9.3 2.6 17.2 3.4 117 21 118 255 -8.9 0 -8.7 -8.9 11/04/2005 22:40:00 9.3 2.6 16.4 3.8 9.2 2.5 15.6 4.2 8.1 2.5 16.8 3 118 22 108 255 -9 0 -8.9 -9.1 11/04/2005 22:50:00 8.7 2.7 16.8 3.4 8.8 2.6 17.2 3.8 7.3 2.6 14.5 1.9 119 23 140 255 -9 0 -8.9 -9.1 11/04/2005 23:00:00 8.4 2.9 17.6 2.6 8.2 2.9 16.4 2.3 7.2 2.6 16.4 1.9 123 24 101 255 -9.1 0 -8.9 -9.3 11/04/2005 23:10:00 8.1 2.7 15.3 2.3 8.1 2.7 15.3 1.5 7.2 2.4 15.3 2.6 119 22 131 255 -9.2 0 -9.1 -9.3 11/04/2005 23:20:00 8.5 2.8 15.6 2.6 8.4 2.7 16.1 2.6 7.2 2.4 14.9 1.1 113 23 100 255 -9.3 0 -9.1 -9.3 11/04/2005 23:30:00 9.3 2.6 15.3 3.4 9.2 2.6 15.3 3.8 8.1 2.4 14.5 3 111 24 138 255 -9.2 0 -9.1 -9.3 11/04/2005 23:40:00 8.8 2.2 14.1 3.4 8.8 2.3 14.1 3 7.5 2.1 13.7 3 118 23 105 255 -9.3 0 -9.3 -9.3 11/04/2005 23:50:00 8.5 3.2 17.6 1.9 8.5 3.1 17.6 2.3 7.1 2.7 16.4 1.9 117 22 115 255 -9.4 0 -9.3 -9.5 11/05/2005 00:00:00 9.7 2.8 19.9 3.8 9.7 2.8 19.5 3.4 8.2 2.5 17.2 3.4 120 21 101 255 -9.4 0 -9.3 -9.5 11/05/2005 00:10:00 9.5 2.8 18.3 4.2 9.4 2.7 17.9 3.4 8.4 2.5 15.6 3.4 116 22 113 255 -9.4 0 -9.3 -9.5 11/05/2005 00:20:00 10 2.9 18.3 3.8 10.1 2.8 17.9 4.6 8.8 2.4 15.6 3.8 117 19 134 255 -9.4 0 -9.3 -9.5 11/05/2005 00:30:00 9.1 2.8 17.6 3.4 9.1 2.8 16.8 1.9 7.9 2.6 15.6 3 118 22 119 255 -9.4 0 -9.3 -9.5 11/05/2005 00:40:00 9.7 2.6 16.8 3.8 9.5 2.5 16.1 3.4 8.2 2.5 15.6 2.6 114 22 106 255 -9.6 0 -9.5 -9.7 11/05/2005 00:50:00 8 2.4 14.1 2.6 8.1 2.4 13.7 2.6 6.9 2.2 12.6 2.6 116 22 95 255 -9.7 0 -9.5 -9.7 11/05/2005 01:00:00 8.5 2.8 16.1 2.3 8.5 2.7 15.6 3 7.2 2.6 14.5 1.1 113 22 108 255 -9.7 0 -9.7 -9.7 11/05/2005 01:10:00 8.6 2.3 14.1 3 8.6 2.1 14.1 3.8 7.4 1.9 12.6 3 112 21 99 255 -9.7 0 -9.5 -9.7 11/05/2005 01:20:00 9.3 2.5 16.8 3 9.2 2.4 15.6 4.2 7.9 2.3 13.7 2.3 109 18 102 255 -9.7 0 -9.7 -9.7 11/05/2005 01:30:00 8.7 2.4 17.6 3.4 8.7 2.2 16.4 3 7.5 2.3 14.9 3.4 110 20 122 255 -9.8 0 -9.7 -10 11/05/2005 01:40:00 8.4 2.6 16.1 3 8.3 2.6 15.6 3.4 7.3 2.3 15.6 3.4 110 19 112 255 -10 0 -9.7 -10.2 11/05/2005 01:50:00 9 2.6 16.4 3.4 8.9 2.6 16.1 3 7.8 2.4 14.5 2.6 106 19 92 255 -10 0 -9.7 -10.2 11/05/2005 02:00:00 8.4 2.4 15.3 2.3 8.4 2.4 14.9 2.6 7.4 2.5 13.3 1.5 100 21 79 255 -9.8 0 -9.7 -10 11/05/2005 02:10:00 8.3 2.5 14.9 3.4 8.2 2.4 15.3 3 7.1 2.2 13.3 3.4 101 17 81 255 -10 0 -9.7 -10.2 11/05/2005 02:20:00 8 2.2 14.9 3.4 7.9 2.1 14.5 3.4 7.1 2 13.3 2.6 105 20 97 255 -10.1 0 -10 -10.2 11/05/2005 02:30:00 8.8 2 15.6 3.4 8.7 2 14.9 3.4 7.5 1.9 13 3 107 20 142 255 -10.1 0 -10 -10.2 11/05/2005 02:40:00 10.5 2.6 17.6 3 10.4 2.5 17.6 4.9 9.3 2.5 15.3 3.8 103 17 131 255 -10.1 0 -10 -10.2 11/05/2005 02:50:00 9.5 2.3 15.6 3.8 9.4 2.2 15.3 4.2 8.2 2.2 14.9 4.2 103 16 102 255 -10.2 0 -10.2 -10.2 11/05/2005 03:00:00 8.6 2.5 15.6 3.4 8.7 2.3 15.3 4.2 7.5 2.4 13.7 2.3 102 18 88 255 -10.2 0 -10 -10.4 11/05/2005 03:10:00 8.8 2.6 14.9 2.3 8.8 2.4 14.9 2.6 7.5 2.3 14.5 1.5 101 20 81 255 -10.2 0 -10.2 -10.4 11/05/2005 03:20:00 9.2 2.9 17.2 4.2 9.1 2.9 16.4 4.2 8.1 2.8 16.8 2.3 100 18 106 255 -10.3 0 -10.2 -10.4 11/05/2005 03:30:00 10.5 3.1 17.9 3.4 10.5 2.9 17.9 4.2 9.2 2.8 16.8 2.3 107 18 100 255 -10.3 0 -10.2 -10.4 11/05/2005 03:40:00 9.4 2.6 15.6 3.4 9.5 2.6 15.6 3 8.3 2.5 14.9 3 104 18 98 255 -10.4 0 -10.2 -10.4 11/05/2005 03:50:00 9.7 2.6 17.9 3.8 9.8 2.5 17.6 3.8 8.6 2.6 16.4 3.8 106 17 75 255 -10.4 0 -10.2 -10.4 11/05/2005 04:00:00 9.6 2.7 16.1 3.8 9.6 2.6 16.1 3 8.4 2.5 17.6 2.3 103 19 63 255 -10.3 0 -10.2 -10.4 11/05/2005 04:10:00 9.5 2.3 15.3 3 9.5 2.2 15.3 4.2 8.4 2.3 14.5 3 101 19 110 255 -10.4 0 -10.2 -10.4 11/05/2005 04:20:00 9.9 2.9 16.8 3.4 9.9 2.8 16.1 3 8.5 2.5 15.6 2.6 108 19 108 255 -10.3 0 -10.2 -10.4 11/05/2005 04:30:00 10 2.5 16.4 4.9 10 2.4 16.1 4.2 8.9 2.4 16.1 3 107 17 106 255 -10.4 0 -10.4 -10.6 11/05/2005 04:40:00 10.1 3.3 17.2 1.9 10.1 3.2 17.2 2.3 8.9 3.1 16.4 1.9 101 22 110 255 -10.4 0 -10.4 -10.4 11/05/2005 04:50:00 10 3.1 18.7 3.4 10.1 3.1 18.3 3.4 8.7 2.9 19.9 1.5 104 19 90 255 -10.4 0 -10.4 -10.4 11/05/2005 05:00:00 9.7 2.6 16.4 3 9.6 2.5 15.6 3.4 8.7 2.3 15.6 3.8 104 19 94 255 -10.4 0 -10.4 -10.6 11/05/2005 05:10:00 9.7 2.2 14.9 3.8 9.6 2.2 14.9 4.2 8.4 2.2 14.1 3.4 104 19 90 255 -10.4 0 -10.4 -10.6 11/05/2005 05:20:00 10 2.5 16.8 4.6 9.9 2.4 16.4 4.6 8.5 2.3 15.3 3 105 17 100 255 -10.4 0 -10.4 -10.6 11/05/2005 05:30:00 9.8 2.7 17.6 3.8 9.8 2.6 17.6 3.8 8.6 2.7 17.2 2.3 102 17 93 255 -10.4 0 -10.4 -10.6 11/05/2005 05:40:00 9 2.4 15.3 3 9 2.4 15.3 3.4 8 2.4 13 1.5 101 17 113 255 -10.4 0 -10.4 -10.6 11/05/2005 05:50:00 9.6 2.5 16.8 3 9.7 2.5 16.8 3 8.5 2.6 17.6 1.9 104 19 109 255 -10.5 0 -10.4 -10.6 11/05/2005 06:00:00 10.1 2.7 16.1 3.4 10.1 2.7 16.1 3.4 8.6 2.7 16.1 2.6 102 17 81 255 -10.5 0 -10.4 -10.6 11/05/2005 06:10:00 8.8 2.5 16.4 2.6 8.7 2.5 16.4 2.6 7.7 2.4 14.9 1.9 100 19 92 255 -10.6 0 -10.6 -10.8 11/05/2005 06:20:00 7.9 2.6 18.7 2.6 7.9 2.6 18.3 2.6 6.9 2.4 16.1 2.6 103 21 112 255 -10.6 0 -10.6 -10.8 11/05/2005 06:30:00 9.3 2.8 16.4 3.4 9.2 2.7 16.4 3.4 8.1 2.5 16.1 2.6 105 22 94 255 -10.5 0 -10.4 -10.8 11/05/2005 06:40:00 9.5 2.4 17.6 4.6 9.4 2.4 16.4 4.2 8.3 2.2 16.1 3.8 109 20 111 255 -10.5 0 -10.4 -10.6 11/05/2005 06:50:00 9.8 2.7 18.3 4.2 9.7 2.7 18.3 4.2 8.8 2.5 16.1 3.4 106 20 104 255 -10.4 0 -10.4 -10.6 11/05/2005 07:00:00 9.9 2.7 17.2 3.8 9.9 2.7 17.6 4.2 8.5 2.6 16.1 3 109 19 80 255 -10.4 0 -10.4 -10.6 11/05/2005 07:10:00 9 2.8 16.1 3.4 9 2.7 16.1 3 7.8 2.4 14.5 2.3 110 21 101 255 -10.4 0 -10.4 -10.6 11/05/2005 07:20:00 9.8 2.6 18.3 4.6 9.8 2.6 17.9 4.6 8.4 2.5 16.4 2.6 107 21 124 255 -10.4 0 -10.2 -10.6 11/05/2005 07:30:00 9.4 2.9 18.3 3 9.2 2.8 18.3 3.4 8.1 2.4 14.5 3 107 22 94 255 -10.4 0 -10.4 -10.6 11/05/2005 07:40:00 10.4 2.8 17.6 3 10.2 2.7 17.2 3 9.2 2.6 15.6 2.3 107 20 97 255 -10.4 0 -10.2 -10.4 11/05/2005 07:50:00 9.5 2.6 16.8 3.4 9.4 2.5 16.1 3.8 8.1 2.6 14.1 3 111 21 115 255 -10.4 0 -10.4 -10.6 11/05/2005 08:00:00 10.7 3.2 17.9 4.2 10.6 3.2 18.7 3.4 9.1 2.8 16.4 3.4 110 20 108 255 -10.4 0 -10.4 -10.4 11/05/2005 08:10:00 10.2 2.8 17.9 3 10.1 2.7 17.2 3 9 2.6 15.6 3 112 19 95 255 -10.4 0 -10.2 -10.6 11/05/2005 08:20:00 10.1 2.5 17.6 4.6 10 2.4 16.8 4.2 8.4 2.5 15.3 2.6 113 22 92 255 -10.4 0 -10.2 -10.6 11/05/2005 08:30:00 8.7 2.2 16.4 4.6 8.6 2.3 15.6 4.6 7.6 2.1 14.1 3 112 21 112 255 -10.5 0 -10.4 -10.6 11/05/2005 08:40:00 9 2.5 15.6 2.6 9 2.4 16.1 3 8.1 2.1 14.9 2.6 106 19 90 255 -10.4 0 -10.2 -10.6 11/05/2005 08:50:00 9.8 2.5 16.1 2.3 9.8 2.5 16.1 2.3 8.7 2.4 14.1 1.1 105 18 116 255 -10.4 0 -10.2 -10.4 11/05/2005 09:00:00 8 2.2 13 3 8 2.2 13.3 3 7.1 2.2 13 2.6 97 20 111 255 -10.4 0 -10.2 -10.4 11/05/2005 09:10:00 6.1 1.7 12.6 2.6 6.1 1.8 13.3 1.9 5.3 1.7 12.6 1.5 97 17 124 255 -10.4 0 -10.2 -10.6 11/05/2005 09:20:00 4 1.2 7.2 0.4 4 1.2 7.2 0.7 3.4 1.1 6.1 0.7 94 22 95 255 -10.4 0 -10.2 -10.6 11/05/2005 09:30:00 5.3 1.4 10.3 2.6 5.2 1.4 10.3 1.9 4.7 1.2 8.8 2.3 98 17 119 255 -10.4 0 -10.2 -10.6 11/05/2005 09:40:00 7.3 1.7 11.5 3 7.3 1.6 11.5 3.4 6.3 1.7 11.1 2.3 104 16 105 255 -10.1 0.1 -9.7 -10.4 11/05/2005 09:50:00 5 1.7 10.3 0.4 5 1.7 10.3 0.7 4.3 1.6 9.1 1.1 94 20 91 255 -9.8 0 -9.7 -9.7 11/05/2005 10:00:00 4.8 1.7 8.8 0.4 4.8 1.6 8.8 0.4 4.4 1.5 8.4 1.1 92 21 100 255 -9.7 0 -9.5 -9.7 11/05/2005 10:10:00 5.2 1.7 9.9 1.9 5.2 1.7 10.3 1.1 4.7 1.5 8.4 1.5 100 20 118 255 -9.4 0.1 -9.3 -9.7 11/05/2005 10:20:00 4.3 1 8 2.6 4.3 0.9 7.2 2.3 3.8 1 6.8 1.5 97 18 68 255 -9.3 0 -9.1 -9.7 11/05/2005 10:30:00 2.4 1.1 5.7 0.4 2.4 1.1 5.3 0.4 2.1 1 4.9 0.4 60 28 100 255 -9.8 0 -9.5 -10 11/05/2005 10:40:00 2.3 0.8 4.2 0.4 2.4 0.7 5.3 0.4 2.2 0.6 3.4 0.4 46 38 42 255 -9.7 0 -9.7 -9.7 11/05/2005 10:50:00 3 1.4 6.5 0.4 3.1 1.3 6.1 0.7 2.6 1.2 5.7 0.4 76 29 99 255 -10 0 -9.7 -10.2 11/05/2005 11:00:00 3.7 1.4 6.8 1.1 3.8 1.3 7.2 1.1 3.3 1.2 6.8 1.1 70 28 110 255 -9.8 0 -9.7 -10 11/05/2005 11:10:00 3.4 1 6.1 0.7 3.4 1 6.1 0.7 3 1 5.3 1.1 72 24 86 255 -9.7 0.1 -9.5 -9.7 11/05/2005 11:20:00 3.9 1.1 7.2 0.4 3.9 1.1 7.6 0.4 3.3 0.9 7.2 0.7 83 27 42 255 -9.3 0.1 -9.1 -9.7 11/05/2005 11:30:00 3.2 1.9 9.9 0.4 3.2 1.8 9.5 0.4 2.9 1.7 8 0.4 57 38 108 255 -9.1 0 -8.9 -9.1 11/05/2005 11:40:00 3.5 1 6.1 1.1 3.5 1 6.5 1.1 3.2 0.8 5.7 1.1 61 26 85 255 -9.3 0 -9.1 -9.3 11/05/2005 11:50:00 2.6 1 5.3 0.4 2.6 1 5.3 0.4 2.5 0.8 4.6 0.7 45 20 45 255 -9.5 0 -9.3 -9.7 11/05/2005 12:00:00 1.9 0.6 3.4 0.4 2 0.6 3.8 0.7 1.7 0.5 3 0.4 47 22 48 255 -9.1 0.2 -8.7 -9.5 11/05/2005 12:10:00 2.6 2.3 11.1 0.4 2.7 2.2 11.1 0.4 2.5 1.8 9.5 0.4 82 33 104 255 -8.4 0.2 -8.1 -8.7 11/05/2005 12:20:00 7.9 2.7 14.9 3.4 7.9 2.6 14.9 2.6 6.8 2.4 13.7 2.3 102 17 93 255 -8 0 -7.9 -8.1 11/05/2005 12:30:00 8.6 2.3 15.3 3.8 8.5 2.2 15.3 3.4 7.6 1.9 13.7 3.8 104 18 105 255 -8.2 0 -8.1 -8.1 11/05/2005 12:40:00 9.7 2.6 16.4 1.9 9.7 2.5 16.1 4.6 8.7 2.3 14.5 3 105 20 128 255 -7.9 0 -7.6 -8.1 11/05/2005 12:50:00 8.9 2.5 14.1 3.4 8.9 2.6 14.5 3 8 2.5 13.7 2.6 95 19 100 255 -7.6 0 -7.4 -7.6 11/05/2005 13:00:00 8.7 2.9 17.6 3.4 8.7 2.8 17.2 2.6 7.8 2.8 16.1 2.3 96 20 91 255 -7.3 0 -7 -7.6 11/05/2005 13:10:00 7.8 2.2 14.5 1.1 7.8 2.1 13.7 2.6 6.8 2.3 12.6 2.3 105 17 111 255 -7 0 -6.8 -7.2 11/05/2005 13:20:00 7 2.1 13.3 1.5 7 2.1 13 1.1 6.2 1.9 11.8 2.3 101 19 95 255 -6.8 0 -6.6 -6.8 11/05/2005 13:30:00 8.1 2.1 14.5 2.6 8 2 14.1 3 7 2 12.6 2.3 108 20 115 255 -6.6 0 -6.6 -6.8 11/05/2005 13:40:00 8 1.9 12.2 3.8 8 1.8 12.2 4.2 7.1 1.8 12.2 2.6 110 18 136 255 -6.8 0 -6.6 -6.8 11/05/2005 13:50:00 8.5 2.5 14.5 3.4 8.5 2.4 15.3 3.8 7.5 2.2 13 1.5 111 18 110 255 -6.4 0.1 -6.1 -6.8 11/05/2005 14:00:00 8.9 2.3 13.7 4.2 8.8 2.2 13.7 3.8 7.9 2.2 13.3 2.6 111 19 113 255 -6.1 0 -6.1 -6.1 11/05/2005 14:10:00 9.3 2.4 17.2 4.2 9.3 2.3 17.2 4.6 8 2.2 14.5 3.4 110 19 116 255 -6.4 0.1 -6.1 -6.6 11/05/2005 14:20:00 9.8 2.6 16.8 4.6 9.8 2.5 16.8 4.9 8.3 2.6 16.8 3 109 19 117 255 -6.2 0 -6.1 -6.6 11/05/2005 14:30:00 9.8 2.4 16.1 4.9 9.8 2.3 16.1 4.2 8.6 2.4 15.3 3 110 17 91 255 -6.4 0 -6.1 -6.4 11/05/2005 14:40:00 10.6 2.8 16.4 2.6 10.6 2.6 16.4 3.8 9.4 2.7 15.3 1.9 106 21 99 255 -6.4 0 -6.1 -6.6 11/05/2005 14:50:00 9.7 2.7 16.8 2.6 9.6 2.7 16.4 2.6 8.6 2.5 15.3 3 110 19 115 255 -6.6 0 -6.6 -6.8 11/05/2005 15:00:00 9.3 2.7 15.3 3 9.3 2.6 16.1 3.8 8.1 2.4 13.7 2.6 107 16 85 255 -6.6 0 -6.6 -6.8 11/05/2005 15:10:00 7.9 2.3 14.9 3.4 7.9 2.2 14.1 3.4 7.1 2.1 13.7 3 111 19 106 255 -6.8 0 -6.6 -6.8 11/05/2005 15:20:00 7.7 2.7 15.3 2.3 7.8 2.6 15.3 2.3 6.8 2.5 14.9 1.5 113 22 87 255 -6.7 0 -6.6 -6.8 11/05/2005 15:30:00 7.6 2.3 15.3 2.3 7.5 2.3 15.3 1.9 6.7 2.4 13 1.5 115 21 130 255 -6.6 0 -6.6 -6.8 11/05/2005 15:40:00 7.3 2 13.7 3.4 7.4 2 13.3 3.4 6.3 1.8 12.6 1.5 118 21 99 255 -6.7 0 -6.6 -6.8 11/05/2005 15:50:00 7.2 2.1 13.7 2.3 7.3 2 13.7 3.4 6.6 1.9 13.3 1.9 122 22 101 255 -6.8 0 -6.6 -6.8 11/05/2005 16:00:00 6.3 2.2 12.6 1.9 6.4 2.1 12.6 1.9 5.9 2 12.2 2.3 132 23 114 255 -6.9 0.1 -6.8 -7 11/05/2005 16:10:00 6.9 2.2 13.3 2.6 7 2.1 13.7 2.6 6.2 1.9 10.7 2.3 132 23 125 255 -6.9 0 -6.8 -7 11/05/2005 16:20:00 7.4 2.1 13.3 2.3 7.4 2 13.3 1.9 6.6 1.8 12.2 1.9 130 20 142 255 -7.1 0 -7 -7 11/05/2005 16:30:00 8 2.9 16.8 2.6 8.1 2.8 16.8 2.6 7 2.5 14.9 1.9 127 21 122 255 -7.1 0 -7 -7.2 11/05/2005 16:40:00 7.5 2.5 14.1 2.3 7.6 2.4 14.5 2.6 6.7 2.1 13 2.3 129 22 140 255 -7.2 0 -7 -7.2 11/05/2005 16:50:00 7.7 2.3 13.7 2.3 7.7 2.3 13.7 2.6 6.7 2.1 11.5 1.1 123 21 114 255 -7.3 0 -7.2 -7.4 11/05/2005 17:00:00 8.1 2.6 14.9 3.4 8.2 2.6 14.9 3 6.9 2.1 13.3 3 128 21 119 255 -7.4 0 -7.2 -7.4 11/05/2005 17:10:00 8.8 2.4 15.6 2.6 8.8 2.3 15.3 2.6 7.8 2.3 14.1 2.6 130 22 99 255 -7.4 0 -7.2 -7.4 11/05/2005 17:20:00 6.4 1.7 11.8 2.6 6.5 1.7 11.5 2.6 5.7 1.7 10.3 1.5 131 21 138 255 -7.5 0 -7.2 -7.6 11/05/2005 17:30:00 6 1.9 11.5 1.5 6.1 1.9 11.8 1.1 5 1.8 9.9 1.9 127 19 111 255 -7.5 0 -7.4 -7.6 11/05/2005 17:40:00 7.1 2.2 12.6 3 7.1 2.1 12.2 3.4 6 1.7 10.7 2.3 126 21 122 255 -7.6 0 -7.4 -7.6 11/05/2005 17:50:00 7.8 2.1 13 3 7.9 1.9 13 3.8 6.6 1.8 11.5 1.9 127 21 110 255 -7.5 0.1 -7.4 -7.6 11/05/2005 18:00:00 8.8 2.6 15.6 3.4 8.9 2.5 15.6 3.8 7.7 2.3 14.1 3.4 119 22 103 255 -7.6 0 -7.4 -7.6 11/05/2005 18:10:00 7.7 2.7 14.5 2.6 7.7 2.6 14.5 2.6 6.7 2.4 14.5 1.5 118 22 131 255 -7.6 0 -7.4 -7.6 11/05/2005 18:20:00 9.1 2.6 16.1 2.3 9.1 2.5 16.1 2.6 7.8 2.5 14.1 1.9 112 21 110 255 -7.7 0 -7.6 -7.9 11/05/2005 18:30:00 8.6 2.5 15.3 3.4 8.6 2.4 14.9 3.4 7.7 2.2 14.5 3 116 20 131 255 -7.9 0.1 -7.6 -8.1 11/05/2005 18:40:00 9.3 2.7 16.8 2.3 9.3 2.6 16.4 3.4 8.2 2.4 16.4 2.6 115 19 93 255 -8 0 -7.9 -8.1 11/05/2005 18:50:00 7.6 2.3 13.3 3 7.6 2.3 13.3 3 6.6 2.1 12.6 2.3 118 21 105 255 -8.1 0 -7.9 -8.3 11/05/2005 19:00:00 7.7 2.5 14.1 2.6 7.7 2.5 14.1 2.6 7.1 2 13.7 2.6 122 18 123 255 -8.2 0 -8.1 -8.3 11/05/2005 19:10:00 7.1 2.3 14.1 2.3 7.1 2.3 13.7 1.9 6.1 2 13.7 1.9 119 24 141 255 -8.1 0 -8.1 -8.1 11/05/2005 19:20:00 7.3 2.4 12.6 2.6 7.4 2.3 12.6 3 6.5 2.2 12.6 2.3 120 22 105 255 -8.2 0 -8.1 -8.1 11/05/2005 19:30:00 6.8 2.2 14.1 2.3 6.9 2.2 13.7 2.3 6.2 2.1 13.3 2.3 120 22 126 255 -8.2 0 -8.1 -8.1 11/05/2005 19:40:00 6.2 2 10.7 1.1 6.2 1.9 10.7 1.5 5.7 1.8 10.3 1.5 123 20 94 255 -8.3 0 -8.1 -8.5 11/05/2005 19:50:00 6.6 2.2 13 1.9 6.6 2.2 13.3 2.3 5.9 2.1 12.2 1.9 123 22 115 255 -8.4 0 -8.3 -8.5 11/05/2005 20:00:00 7.8 2.3 14.5 3.4 7.7 2.2 13.7 3 6.7 2.1 12.6 1.9 115 24 87 255 -8.3 0 -8.3 -8.5 11/05/2005 20:10:00 8 2.8 14.1 1.1 8 2.7 14.5 1.9 7 2.5 12.2 1.9 116 22 139 255 -8.5 0 -8.5 -8.7 11/05/2005 20:20:00 6.8 2.3 15.3 1.9 6.8 2.2 15.3 2.3 6 2.1 14.5 1.9 120 22 106 255 -8.6 0 -8.5 -8.7 11/05/2005 20:30:00 5.5 1.9 11.1 1.5 5.6 1.8 11.1 1.9 4.9 1.6 11.1 1.5 126 24 120 255 -9 0 -8.7 -9.1 11/05/2005 20:40:00 5.5 1.9 12.6 1.5 5.6 1.8 12.6 1.5 5.2 1.6 9.1 1.5 127 24 101 255 -9 0 -8.9 -9.1 11/05/2005 20:50:00 6.5 2 12.2 1.5 6.5 1.9 12.2 1.9 5.8 1.7 10.7 1.5 120 22 117 255 -8.9 0 -8.7 -8.9 11/05/2005 21:00:00 5.6 1.7 9.9 2.3 5.8 1.5 9.5 1.9 5 1.4 9.5 1.5 126 20 109 255 -9.1 0.1 -8.7 -9.3 11/05/2005 21:10:00 6 1.7 12.2 1.9 6.1 1.7 11.8 1.9 5.2 1.7 10.7 1.5 128 19 144 255 -9.3 0 -9.1 -9.3 11/05/2005 21:20:00 5.2 2 10.7 1.5 5.4 1.8 10.3 1.9 4.9 1.6 10.7 1.9 120 20 111 255 -9.3 0 -9.3 -9.3 11/05/2005 21:30:00 5.7 2 12.2 1.5 5.8 1.9 12.2 1.9 5.1 1.4 10.7 2.3 122 20 112 255 -9.3 0 -9.3 -9.3 11/05/2005 21:40:00 5.8 1.5 11.1 2.6 5.9 1.4 10.7 3.4 5.3 1.5 10.3 1.9 123 19 117 255 -9.4 0 -9.3 -9.5 11/05/2005 21:50:00 5.2 1.5 9.9 1.1 5.4 1.5 9.9 1.9 4.5 1.4 9.1 1.5 122 24 127 255 -9.5 0 -9.3 -9.7 11/05/2005 22:00:00 5.5 1.7 11.5 2.3 5.7 1.6 11.1 2.6 4.8 1.3 9.1 1.9 121 22 177 255 -9.6 0 -9.3 -9.7 11/05/2005 22:10:00 5.7 1.7 10.3 1.9 5.7 1.7 9.9 1.9 5 1.5 9.5 1.5 120 22 110 255 -9.7 0 -9.5 -9.7 11/05/2005 22:20:00 5.1 1.6 10.3 1.1 5.1 1.5 9.9 1.5 4.7 1.5 9.5 1.5 118 22 106 255 -9.9 0 -9.7 -10.2 11/05/2005 22:30:00 5.5 1.9 11.1 1.1 5.5 1.8 11.1 1.9 4.9 1.8 10.7 0.4 118 19 89 255 -10 0 -9.7 -10.2 11/05/2005 22:40:00 5.1 1.8 9.5 1.1 5.3 1.7 9.1 1.5 4.6 1.5 8.4 0.4 120 20 117 255 -10.1 0 -10.2 -10.2 11/05/2005 22:50:00 4.5 1.5 9.1 1.1 4.6 1.5 8.4 1.5 4.3 1.4 8.4 1.9 116 19 113 255 -10.3 0 -10.2 -10.4 11/05/2005 23:00:00 5 1.3 8.8 1.9 5 1.2 8.4 1.9 4.4 1.2 8.4 1.5 123 17 127 255 -10.4 0 -10.2 -10.4 11/05/2005 23:10:00 4.1 1.3 8 0.7 4.2 1.3 8.4 1.1 3.7 1 6.8 1.5 119 24 126 255 -10.4 0 -10.4 -10.6 11/05/2005 23:20:00 5.4 1.6 9.9 2.3 5.5 1.5 9.5 2.6 4.7 1.5 9.1 1.9 111 17 106 255 -10.5 0 -10.4 -10.6 11/05/2005 23:30:00 5 1.5 8.8 1.5 5 1.5 9.5 1.5 4.4 1.3 8.4 1.1 117 17 140 255 -10.5 0 -10.4 -10.6 11/05/2005 23:40:00 5.2 1.6 9.5 1.9 5.2 1.5 9.1 1.9 4.5 1.5 9.5 1.5 116 21 109 255 -10.6 0 -10.6 -10.8 11/05/2005 23:50:00 4.6 1.5 9.1 1.1 4.7 1.5 9.5 0.7 4.1 1.5 8.4 1.1 113 17 109 255 -10.7 0 -10.6 -11 11/06/2005 00:00:00 4.4 1.7 9.9 0.7 4.5 1.7 9.5 0.7 4 1.3 8.8 0.7 118 20 94 255 -10.9 0 -10.8 -11 11/06/2005 00:10:00 4.7 1.3 9.5 1.1 4.9 1.4 9.9 1.9 4.1 1.2 8.4 1.5 105 19 131 255 -11 0 -11 -11 11/06/2005 00:20:00 4.9 1.2 7.6 1.9 5 1.2 8 2.3 4.4 1.2 7.6 1.5 95 17 109 255 -11.1 0 -11 -11.2 11/06/2005 00:30:00 5.2 1.4 8.8 1.9 5.3 1.3 9.1 1.9 4.6 1.2 8 2.3 81 18 53 255 -11.1 0 -11 -11.2 11/06/2005 00:40:00 5.7 1.6 10.3 2.3 5.8 1.5 10.3 2.6 4.9 1.4 8.8 2.3 85 15 72 255 -11 0 -11 -11.2 11/06/2005 00:50:00 4.2 1.1 7.2 1.9 4.3 1.1 7.2 1.5 3.8 1.1 6.5 0.4 92 19 74 255 -11.2 0 -11 -11.2 11/06/2005 01:00:00 4.4 1.2 7.6 1.5 4.6 1.2 7.6 1.9 4 1.3 7.2 1.1 86 17 72 255 -11.2 0 -11 -11.4 11/06/2005 01:10:00 4.5 1.2 7.6 1.9 4.5 1.2 7.2 1.9 3.9 1.2 7.2 1.5 90 15 92 255 -11.3 0.1 -11.2 -11.4 11/06/2005 01:20:00 3.2 1.3 6.5 0.7 3.5 1.1 6.5 0.4 2.8 1 5.7 0.7 100 26 95 255 -11.5 0 -11.4 -11.6 11/06/2005 01:30:00 1.7 0.8 4.6 0.4 1.9 0.7 4.6 0.7 1.4 0.7 3.4 0.4 99 28 102 255 -11.5 0 -11.4 -11.6 11/06/2005 01:40:00 1.2 1.2 5.3 0.4 1.3 1.2 4.9 0.4 1.1 1 4.9 0.4 70 28 125 255 -12 0.3 -11.6 -12.4 11/06/2005 01:50:00 2.3 0.6 4.2 1.1 2.4 0.6 4.2 1.1 2 0.6 3.8 0.7 77 26 109 255 -12.4 0 -12.2 -12.6 11/06/2005 02:00:00 2.4 0.4 3.4 0.4 2.6 0.4 3.4 0.7 2 0.5 3 0.4 66 13 74 255 -12.7 0.1 -12.4 -13 11/06/2005 02:10:00 2.4 0.6 4.2 0.7 2.6 0.6 4.2 1.1 2.2 0.5 3.8 0.7 70 12 77 255 -13.1 0 -12.8 -13.4 11/06/2005 02:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.6 0.4 3.8 1.5 81 10 43 255 -13.5 0 -13.2 -13.6 11/06/2005 02:30:00 3.5 0.5 4.6 2.3 3.6 0.5 4.6 2.6 2.8 0.5 4.2 1.5 74 10 98 255 -13.5 0.2 -13.2 -13.6 11/06/2005 02:40:00 3.4 0.6 4.6 1.9 3.5 0.6 4.6 1.9 2.9 0.6 4.2 1.1 78 9 80 255 -13 0.1 -12.8 -13.2 11/06/2005 02:50:00 3 0.7 4.6 1.5 3.1 0.6 4.6 1.5 2.5 0.6 3.8 1.1 78 9 84 255 -12.7 0 -12.6 -12.8 11/06/2005 03:00:00 3.3 0.6 4.9 1.9 3.3 0.5 4.6 1.9 2.6 0.5 4.2 1.1 75 9 79 255 -12.6 0 -12.6 -12.6 11/06/2005 03:10:00 2.6 0.7 4.2 1.1 2.7 0.6 4.2 1.5 2.2 0.6 3.8 0.7 77 12 75 255 -12.5 0 -12.4 -12.6 11/06/2005 03:20:00 2.8 0.5 4.2 1.1 3 0.5 4.2 1.5 2.4 0.6 3.8 0.7 79 9 71 255 -12.4 0 -12.2 -12.4 11/06/2005 03:30:00 2.1 0.8 4.6 0.4 2.3 0.8 4.6 0.4 1.7 0.7 3.8 0.4 72 15 90 255 -12.3 0 -12.2 -12.4 11/06/2005 03:40:00 1.3 0.6 3 0.4 1.5 0.5 3 0.4 1.2 0.5 2.6 0.4 79 15 64 255 -12.2 0 -12.2 -12.2 11/06/2005 03:50:00 2.2 0.6 3.4 0.7 2.3 0.5 3.4 0.7 1.8 0.5 3.4 0.4 96 11 87 255 -12.2 0 -12.2 -12.2 11/06/2005 04:00:00 2.5 0.7 4.2 0.4 2.6 0.7 4.2 1.1 2.1 0.7 4.2 0.7 88 11 109 255 -12.1 0 -12 -12.2 11/06/2005 04:10:00 2.3 0.5 3.4 0.4 2.4 0.5 3.8 0.4 1.9 0.5 3 0.4 88 13 68 255 -12 0 -11.8 -12 11/06/2005 04:20:00 2.1 0.7 4.2 0.4 2.2 0.6 4.2 0.4 1.9 0.6 3.8 0.7 102 13 105 255 -11.9 0 -11.8 -12 11/06/2005 04:30:00 2.7 0.8 4.6 0.4 2.8 0.7 4.2 0.7 2.3 0.8 3.8 0.4 111 14 125 255 -11.9 0 -11.8 -11.8 11/06/2005 04:40:00 2.6 0.7 4.2 0.4 2.7 0.7 4.2 0.7 2.2 0.8 4.2 0.4 107 15 101 255 -11.9 0 -11.8 -11.8 11/06/2005 04:50:00 2.6 0.8 4.2 0.7 2.7 0.7 4.2 1.1 2.3 0.7 3.8 0.7 94 12 99 255 -11.8 0 -11.6 -11.8 11/06/2005 05:00:00 2.3 0.6 3.8 0.7 2.5 0.5 3.8 1.1 2.1 0.6 3.8 1.1 97 11 103 255 -11.6 0 -11.4 -11.8 11/06/2005 05:10:00 3.1 0.6 4.6 1.5 3.2 0.6 4.9 1.5 2.7 0.7 4.2 0.7 102 11 108 255 -11.5 0 -11.4 -11.6 11/06/2005 05:20:00 3.3 0.9 5.3 0.7 3.4 0.8 4.9 1.5 2.9 0.8 4.9 1.5 104 11 104 255 -11.5 0 -11.4 -11.6 11/06/2005 05:30:00 3.2 0.8 5.3 1.1 3.3 0.8 5.3 1.5 2.9 0.8 4.9 0.7 105 13 99 255 -11.5 0 -11.4 -11.4 11/06/2005 05:40:00 3.2 0.8 4.9 1.5 3.3 0.7 4.9 1.5 2.7 0.7 4.6 1.1 104 17 102 255 -11.3 0 -11.2 -11.4 11/06/2005 05:50:00 3.1 0.6 4.6 1.5 3.2 0.6 4.9 1.5 2.8 0.7 4.6 1.1 105 15 84 255 -11.2 0 -11.2 -11.4 11/06/2005 06:00:00 3.2 0.7 4.9 1.5 3.2 0.6 4.6 1.5 2.9 0.6 4.6 1.5 106 15 97 255 -11.2 0 -11.2 -11.4 11/06/2005 06:10:00 3 0.6 4.6 1.5 3.1 0.6 4.9 1.9 2.8 0.6 4.2 0.7 111 13 98 255 -11.2 0 -11.2 -11.4 11/06/2005 06:20:00 3.7 0.8 5.3 1.5 3.8 0.7 5.3 1.9 3.2 0.8 4.9 1.5 106 13 110 255 -11.3 0 -11.2 -11.4 11/06/2005 06:30:00 3.6 0.7 5.3 1.9 3.7 0.6 5.3 2.3 3.1 0.7 4.9 1.5 104 13 100 255 -11.3 0 -11.2 -11.4 11/06/2005 06:40:00 3.6 0.9 5.3 1.5 3.7 0.9 5.7 1.5 3.3 0.9 5.3 1.1 108 13 116 255 -11.2 0 -11 -11.4 11/06/2005 06:50:00 3.6 0.8 5.3 1.5 3.6 0.8 5.3 1.9 3.1 0.8 5.3 1.1 111 13 115 255 -11.2 0 -11 -11.2 11/06/2005 07:00:00 2 1 4.2 0.4 2.1 0.9 4.2 0.4 1.9 0.7 4.2 0.4 123 16 109 255 -11 0 -11 -11.2 11/06/2005 07:10:00 1.4 0.7 3 0.4 1.6 0.6 3 0.4 1.4 0.5 2.6 0.4 135 18 131 255 -10.9 0 -11 -11 11/06/2005 07:20:00 2.8 0.9 4.9 0.7 2.9 0.8 4.6 0.7 2.5 0.8 4.6 0.7 119 13 115 255 -10.8 0 -10.8 -11 11/06/2005 07:30:00 3.2 0.8 5.3 1.1 3.3 0.7 5.3 1.5 2.8 0.8 4.9 1.1 105 15 92 255 -10.8 0 -10.6 -11 11/06/2005 07:40:00 3.6 1 5.3 0.7 3.7 0.9 5.7 1.1 3.1 0.9 5.3 0.7 96 13 109 255 -10.8 0 -10.6 -11 11/06/2005 07:50:00 2.8 1 4.9 0.7 2.9 0.9 4.9 0.7 2.5 1 4.6 0.4 90 20 76 255 -10.8 0 -10.6 -11 11/06/2005 08:00:00 2.9 0.8 4.9 1.1 3.1 0.8 4.9 1.1 2.7 0.8 4.9 1.1 84 16 74 255 -10.7 0 -10.6 -10.8 11/06/2005 08:10:00 3.2 1.2 6.1 0.7 3.4 1.2 6.1 0.7 3.1 1.1 5.7 0.7 94 17 97 255 -10.6 0 -10.6 -10.8 11/06/2005 08:20:00 4.2 1.2 7.6 1.5 4.3 1.2 7.6 1.9 3.6 1.1 7.2 1.5 97 15 88 255 -10.6 0 -10.6 -10.8 11/06/2005 08:30:00 4.3 1.2 7.6 1.5 4.4 1.2 7.6 1.9 3.9 1.1 7.2 1.1 101 19 116 255 -10.6 0 -10.6 -10.8 11/06/2005 08:40:00 4.7 1.5 8.8 1.1 5 1.4 9.1 1.9 4.4 1.2 8.8 1.1 102 17 94 255 -10.8 0.1 -10.6 -11.2 11/06/2005 08:50:00 5.1 1.7 11.5 1.9 5.3 1.5 10.7 1.9 4.5 1.5 8.4 1.5 99 20 105 255 -11.4 0 -11 -11.4 11/06/2005 09:00:00 5.2 1.9 10.3 1.9 5.3 1.7 9.9 1.5 4.6 1.7 9.5 1.5 97 18 86 255 -11.4 0 -11.4 -11.4 11/06/2005 09:10:00 6.5 1.9 11.5 2.3 6.6 1.7 11.1 3 6 1.8 10.7 1.9 96 18 103 255 -11.3 0 -11.2 -11.4 11/06/2005 09:20:00 5.1 1.5 9.9 1.9 5.2 1.4 9.9 1.5 4.5 1.5 9.5 1.5 93 19 98 255 -11.2 0 -11 -11.4 11/06/2005 09:30:00 5.4 1.7 9.5 1.9 5.6 1.7 9.5 2.3 4.7 1.7 8.8 0.7 87 19 116 255 -11.1 0 -11 -11.2 11/06/2005 09:40:00 5.3 1.8 9.9 1.1 5.4 1.7 9.9 1.9 4.7 1.6 9.1 1.9 90 17 85 255 -11.1 0 -11 -11.2 11/06/2005 09:50:00 5.6 1.5 9.1 2.3 5.7 1.4 8.8 1.5 5.1 1.3 8.4 2.3 97 17 88 255 -11 0 -11 -11.2 11/06/2005 10:00:00 6.1 1.5 9.9 2.3 6.3 1.4 10.3 3 5.5 1.5 9.1 1.9 94 15 104 255 -10.9 0 -11 -11 11/06/2005 10:10:00 4.3 1.3 8.4 0.4 4.5 1.3 8.4 1.5 3.9 1.3 8 1.1 95 19 81 255 -10.9 0 -10.8 -11 11/06/2005 10:20:00 4.2 1 7.2 2.3 4.3 1 7.2 2.3 3.7 1 6.5 1.9 97 14 103 255 -10.8 0 -10.6 -10.8 11/06/2005 10:30:00 4.4 1.1 6.8 1.5 4.4 1 6.8 2.3 3.9 1 6.8 1.1 93 13 101 255 -10.7 0 -10.6 -10.8 11/06/2005 10:40:00 3.5 0.9 5.7 1.5 3.6 0.8 5.7 1.1 3.3 0.8 6.1 1.1 95 14 88 255 -10.5 0 -10.4 -10.6 11/06/2005 10:50:00 4 0.8 5.7 1.9 4.1 0.7 5.7 2.3 3.8 0.8 5.7 1.9 95 13 92 255 -10.5 0 -10.4 -10.6 11/06/2005 11:00:00 3.9 1.3 7.2 1.1 3.9 1.2 7.2 1.5 3.4 1 5.7 1.5 94 17 119 255 -10.4 0 -10.4 -10.6 11/06/2005 11:10:00 3.2 1 5.7 0.4 3.2 1 5.3 0.4 2.9 0.9 4.9 0.4 94 17 71 255 -10.3 0 -10.2 -10.4 11/06/2005 11:20:00 3.7 1 6.1 1.5 3.7 0.9 6.5 1.9 3.3 0.8 5.3 1.5 102 12 90 255 -10.3 0 -10.2 -10.4 11/06/2005 11:30:00 4.1 0.8 5.3 1.9 4 0.7 5.7 2.3 3.7 0.8 6.1 1.9 108 12 108 255 -10.4 0 -10.2 -10.6 11/06/2005 11:40:00 3.7 0.8 5.3 1.9 3.6 0.7 5.3 1.5 3.2 0.8 5.3 1.1 103 13 104 255 -10.4 0 -10.4 -10.6 11/06/2005 11:50:00 3.4 1 6.1 1.5 3.4 1 6.1 1.5 3 1 5.3 1.1 109 15 92 255 -10.4 0 -10.4 -10.6 11/06/2005 12:00:00 3.2 0.9 5.3 1.5 3.2 0.8 5.3 1.5 2.8 0.9 6.1 0.7 111 15 108 255 -10.5 0 -10.4 -10.6 11/06/2005 12:10:00 3.1 1 5.3 0.7 3.1 1 5.3 0.7 2.9 0.9 5.3 0.7 116 19 127 255 -10.5 0 -10.4 -10.6 11/06/2005 12:20:00 2.6 1 5.7 0.4 2.6 0.9 5.7 0.4 2.2 0.8 4.2 0.4 115 19 118 255 -10.5 0 -10.4 -10.6 11/06/2005 12:30:00 3.5 0.9 5.7 0.4 3.5 0.9 5.7 1.5 3.2 0.7 4.9 1.1 112 16 111 255 -10.3 0 -10.2 -10.4 11/06/2005 12:40:00 2.9 0.8 4.9 0.7 2.9 0.8 4.6 1.1 2.8 0.8 4.9 0.4 109 19 108 255 -9.9 0 -9.7 -10.2 11/06/2005 12:50:00 2.8 0.8 4.9 0.7 2.9 0.8 5.3 0.7 2.6 0.8 4.9 0.7 108 17 112 255 -9.7 0 -9.5 -10 11/06/2005 13:00:00 2.9 1 7.2 0.7 3 0.9 7.2 0.7 2.6 0.8 5.7 0.7 106 21 86 255 -9.4 0.1 -9.1 -9.7 11/06/2005 13:10:00 3.7 1.1 6.5 0.4 3.7 1 6.5 1.1 3.4 1 5.7 0.7 96 13 118 255 -9.1 0 -8.9 -9.3 11/06/2005 13:20:00 3.3 1 5.7 1.1 3.4 0.9 5.7 1.5 3 1 5.3 0.7 113 22 108 255 -8.8 0 -8.7 -8.9 11/06/2005 13:30:00 4 1.5 8 0.7 4.1 1.3 8 0.4 3.7 1.3 7.2 1.5 117 21 127 255 -8.9 0 -8.7 -8.9 11/06/2005 13:40:00 4.5 1.2 7.6 1.9 4.5 1.2 7.6 1.9 4.1 1.1 6.5 1.5 109 18 79 255 -9.1 0.1 -8.9 -9.3 11/06/2005 13:50:00 5.8 1.7 10.3 1.9 5.8 1.6 10.3 2.3 4.9 1.6 9.9 1.1 108 19 117 255 -8.9 0 -8.9 -9.1 11/06/2005 14:00:00 6.6 1.5 9.9 3.4 6.5 1.4 9.9 3.4 5.7 1.4 10.3 2.6 112 19 99 255 -8.8 0 -8.7 -8.9 11/06/2005 14:10:00 5.4 1.5 8.8 1.9 5.3 1.4 8.4 1.9 4.9 1.3 7.6 1.9 113 21 97 255 -8.9 0.1 -8.7 -9.1 11/06/2005 14:20:00 5.3 1.9 10.3 1.5 5.3 1.8 9.9 1.5 4.7 1.9 9.9 0.4 115 22 119 255 -8.8 0 -8.5 -8.9 11/06/2005 14:30:00 5.4 1.7 9.5 1.5 5.4 1.7 9.5 1.5 5.1 1.6 8.8 1.1 105 17 99 255 -8.7 0 -8.7 -8.9 11/06/2005 14:40:00 4.9 1.4 8.4 1.9 4.9 1.4 8 1.5 4.6 1.4 8.8 1.9 111 19 104 255 -8.8 0 -8.7 -8.9 11/06/2005 14:50:00 4.9 1.4 8.8 1.5 4.9 1.3 8.4 1.9 4.3 1.2 7.2 2.3 126 22 138 255 -9 0.1 -8.7 -9.3 11/06/2005 15:00:00 4 1.4 8.8 1.5 4 1.4 8.4 1.1 3.3 1.2 6.1 1.1 125 26 121 255 -9.2 0 -9.1 -9.3 11/06/2005 15:10:00 4.2 1.3 8.8 1.1 4.2 1.2 8.8 1.1 4 1.1 8.4 1.9 127 22 130 255 -9.3 0 -9.3 -9.3 11/06/2005 15:20:00 4.1 1.1 6.5 1.5 4 1.1 6.8 1.5 3.5 1 7.2 1.1 125 22 112 255 -9.3 0 -9.3 -9.3 11/06/2005 15:30:00 3.4 1.2 6.8 0.7 3.4 1.2 7.2 1.1 3 1.1 6.8 0.7 121 22 98 255 -9.4 0.1 -9.3 -9.7 11/06/2005 15:40:00 3.4 1.7 8 0.4 3.4 1.5 8 0.7 3.1 1.4 6.5 0.4 132 22 88 255 -9.6 0 -9.5 -9.7 11/06/2005 15:50:00 3.1 1 5.7 0.7 3.1 1 5.7 0.7 2.8 1 5.3 0.7 120 18 117 255 -9.6 0 -9.5 -9.7 11/06/2005 16:00:00 2.3 1 4.6 0.4 2.3 0.9 4.6 0.4 2 0.8 4.2 0.4 127 22 121 255 -9.5 0 -9.3 -9.7 11/06/2005 16:10:00 2 1 5.3 0.4 2 0.9 4.6 0.4 2 0.8 4.9 0.7 139 22 116 255 -9.6 0 -9.3 -9.7 11/06/2005 16:20:00 2.5 0.9 4.6 0.7 2.6 0.8 4.6 0.4 2.5 0.8 4.6 0.7 148 21 110 255 -9.8 0 -9.7 -10 11/06/2005 16:30:00 3 1 5.7 0.7 3 1 5.7 0.7 2.4 1 4.9 0.4 130 18 117 255 -9.9 0 -9.7 -10 11/06/2005 16:40:00 3.1 1.3 6.1 0.4 3.1 1.2 5.7 0.4 2.8 1.1 5.3 0.4 117 18 98 255 -9.8 0 -9.7 -9.7 11/06/2005 16:50:00 1.4 0.9 4.2 0.4 1.4 1 3.8 0.4 1.2 0.7 3 0.4 126 33 117 255 -9.9 0 -9.7 -10.2 11/06/2005 17:00:00 2 1 4.9 0.4 1.9 0.9 4.6 0.4 1.6 0.8 4.2 0.4 127 17 98 255 -10.2 0 -10 -10.4 11/06/2005 17:10:00 2.1 0.9 4.2 0.4 2.1 0.8 4.6 0.4 1.8 0.7 3.8 0.4 130 26 140 255 -10.5 0 -10.2 -10.8 11/06/2005 17:20:00 1.1 0.6 3 0.4 1.2 0.6 2.6 0.4 1.3 0.6 3 0.4 194 36 134 255 -10.9 0.1 -10.6 -11.2 11/06/2005 17:30:00 1 0.6 2.6 0.4 1 0.6 2.3 0.4 1 0.5 2.3 0.4 232 15 214 255 -11.6 0.2 -11.2 -12 11/06/2005 17:40:00 1.2 0.6 3 0.4 1.3 0.6 3 0.4 1.2 0.5 2.6 0.4 225 11 226 255 -12.2 0.1 -11.8 -12.6 11/06/2005 17:50:00 0.7 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.7 0.4 1.9 0.4 233 27 239 255 -12.8 0.2 -12.6 -13.2 11/06/2005 18:00:00 1 0.7 3 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.6 0.4 193 30 221 255 -13.3 0.1 -13.2 -13.6 11/06/2005 18:10:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1 0.5 2.3 0.4 219 15 201 255 -13.7 0 -13.6 -13.8 11/06/2005 18:20:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.4 1.9 0.4 228 8 225 255 -14 0.1 -13.8 -14.2 11/06/2005 18:30:00 1.4 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.1 0.3 2.3 0.4 222 8 218 255 -14.1 0 -14 -14.2 11/06/2005 18:40:00 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 1 0.4 1.9 0.4 193 15 204 255 -14.3 0.1 -14.2 -14.8 11/06/2005 18:50:00 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 1.3 0.4 2.3 0.4 127 27 84 255 -14.8 0 -14.6 -15 11/06/2005 19:00:00 1.1 0.4 2.3 0.4 1.1 0.3 2.3 0.4 1.3 0.3 2.3 0.7 98 6 113 255 -14.9 0 -14.8 -15 11/06/2005 19:10:00 1.8 0.6 3 0.7 1.9 0.6 3 0.7 1.7 0.4 2.6 0.7 115 8 124 255 -15.1 0.1 -15 -15.3 11/06/2005 19:20:00 1.9 0.5 2.6 0.4 1.9 0.5 3 0.4 1.5 0.4 2.6 0.4 102 8 93 255 -15 0.1 -14.8 -15.3 11/06/2005 19:30:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.4 0.5 3.4 1.1 97 6 94 255 -14.1 0.4 -13.4 -14.8 11/06/2005 19:40:00 2.5 0.5 3.4 0.7 2.5 0.5 3.4 0.7 2.1 0.4 3 1.1 109 8 112 255 -12.9 0.3 -12.2 -13.4 11/06/2005 19:50:00 1.9 0.7 3 0.4 1.9 0.7 3.4 0.4 1.4 0.7 2.6 0.4 114 14 100 255 -12.1 0 -12 -12.2 11/06/2005 20:00:00 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.4 0.6 3 0.4 107 14 127 255 -12 0 -11.8 -12.2 11/06/2005 20:10:00 2 0.8 3.4 0.4 2 0.8 3.8 0.4 1.7 0.7 3.4 0.4 107 13 129 255 -11.8 0 -11.6 -11.8 11/06/2005 20:20:00 2 1 3.8 0.4 2 1 4.2 0.4 1.7 0.8 3.4 0.4 114 19 100 255 -11.5 0 -11.4 -11.6 11/06/2005 20:30:00 3.2 0.6 4.6 1.1 3.1 0.6 4.6 1.5 2.7 0.6 4.2 1.1 107 10 106 255 -11.5 0 -11.4 -11.6 11/06/2005 20:40:00 3.2 0.4 4.2 1.9 3.2 0.5 4.2 1.5 2.9 0.5 4.2 1.5 108 9 101 255 -11.7 0 -11.4 -11.8 11/06/2005 20:50:00 3.5 0.7 4.9 1.5 3.5 0.7 4.6 1.5 3 0.7 4.6 0.7 112 12 96 255 -11.9 0 -11.8 -12 11/06/2005 21:00:00 3.7 0.6 4.9 2.3 3.6 0.6 4.9 1.9 3.1 0.6 4.6 1.1 104 10 108 255 -12 0 -11.8 -12 11/06/2005 21:10:00 3.7 0.7 5.3 1.9 3.8 0.7 5.3 1.9 3.1 0.7 4.6 1.5 107 12 109 255 -12 0 -12 -12.2 11/06/2005 21:20:00 3.7 0.8 5.3 1.5 3.6 0.8 5.3 1.5 3.1 0.8 4.9 1.1 108 12 104 255 -12 0 -12 -12.2 11/06/2005 21:30:00 3.5 1 5.3 1.1 3.5 1 5.3 1.1 3 1 4.9 0.4 109 17 100 255 -12.1 0 -12 -12.2 11/06/2005 21:40:00 3.8 0.9 6.1 0.7 3.7 0.9 6.1 0.7 3.3 0.9 5.3 1.1 109 12 112 255 -12.3 0 -12.2 -12.4 11/06/2005 21:50:00 2.9 1 4.9 0.4 3 1 4.9 0.4 2.6 1 4.6 0.4 114 19 101 255 -12.6 0 -12.4 -12.6 11/06/2005 22:00:00 2.7 1 4.9 0.4 2.7 0.9 4.6 0.4 2.4 0.8 4.9 0.4 118 15 113 255 -12.9 0.1 -12.6 -13.2 11/06/2005 22:10:00 2.9 0.8 5.3 0.7 3 0.8 5.3 0.7 2.4 0.8 4.6 0.7 116 19 136 255 -13.2 0 -13 -13.4 11/06/2005 22:20:00 3.5 0.9 5.7 1.1 3.5 0.8 5.3 1.1 2.8 0.8 4.9 0.7 115 15 117 255 -13.5 0 -13.2 -13.6 11/06/2005 22:30:00 3.9 0.8 5.7 1.5 3.9 0.8 5.7 1.5 3.3 0.8 6.1 1.5 116 13 136 255 -13.7 0 -13.6 -13.6 11/06/2005 22:40:00 3.6 1 6.1 0.4 3.6 1 5.7 0.7 3 0.9 5.3 1.1 115 15 102 255 -13.7 0 -13.6 -13.8 11/06/2005 22:50:00 3.7 1 6.1 1.1 3.6 1 6.1 1.1 2.8 1 5.3 0.7 112 13 105 255 -13.8 0 -13.6 -14 11/06/2005 23:00:00 3.8 0.8 5.7 1.9 3.8 0.7 5.3 1.9 3.1 0.8 5.7 1.1 118 13 113 255 -14 0 -13.8 -14 11/06/2005 23:10:00 3.3 1 5.7 0.7 3.4 1 5.3 0.7 2.9 0.8 5.3 1.1 118 17 115 255 -14.1 0 -13.8 -14.2 11/06/2005 23:20:00 3.9 0.8 6.1 1.9 3.9 0.8 5.7 1.9 3.1 0.9 5.7 1.1 118 14 114 255 -14.2 0 -14 -14.2 11/06/2005 23:30:00 3.2 1 6.1 0.7 3.1 1 6.1 0.7 2.6 0.8 5.3 0.7 118 16 93 255 -14.2 0 -14 -14.2 11/06/2005 23:40:00 3.7 1 6.1 1.1 3.7 0.9 5.7 1.1 3 0.9 5.3 0.7 113 14 109 255 -14.2 0 -14 -14.2 11/06/2005 23:50:00 3.7 0.9 5.7 1.1 3.6 0.9 5.3 0.7 3 0.9 4.9 0.7 115 14 102 255 -14.2 0 -14 -14.2 11/07/2005 00:00:00 4.1 1 6.1 1.1 4 0.9 6.1 1.5 3.4 0.8 4.9 1.9 111 13 110 255 -14.1 0 -14 -14.2 11/07/2005 00:10:00 3 0.8 4.9 1.1 3 0.8 5.3 0.7 2.5 0.7 4.6 0.4 121 16 110 255 -14.1 0 -14 -14 11/07/2005 00:20:00 3.2 0.7 4.9 1.5 3.2 0.7 4.9 1.5 2.6 0.7 5.3 0.4 118 15 103 255 -14.1 0 -14 -14.2 11/07/2005 00:30:00 3.2 1 5.7 0.7 3.2 0.9 5.3 0.7 2.7 0.8 4.9 0.7 123 16 101 255 -14.1 0.1 -14 -14.2 11/07/2005 00:40:00 3.2 0.8 5.3 1.1 3.2 0.7 5.3 1.1 2.6 0.7 4.6 1.1 126 14 127 255 -14.3 0 -14 -14.6 11/07/2005 00:50:00 2.7 0.8 4.2 0.4 2.7 0.8 4.6 0.7 2.3 0.7 4.2 0.4 126 13 126 255 -14.3 0 -14 -14.6 11/07/2005 01:00:00 2.8 0.6 4.2 1.1 2.8 0.5 4.2 1.5 2.4 0.5 3.4 1.1 133 12 123 255 -14.7 0 -14.4 -14.8 11/07/2005 01:10:00 2.9 0.6 4.9 1.5 3 0.6 4.9 1.5 2.4 0.6 4.6 1.1 128 10 126 255 -15 0.1 -14.6 -15.3 11/07/2005 01:20:00 2.2 0.7 3.8 0.4 2.2 0.6 3.4 0.7 1.5 0.5 3.4 0.4 133 14 126 255 -15.9 0.3 -15.1 -16.3 11/07/2005 01:30:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.2 0.5 3.4 0.7 136 10 129 255 -16.4 0 -16.3 -16.5 11/07/2005 01:40:00 2.6 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2 0.6 3.4 0.7 134 11 127 255 -16.7 0.1 -16.5 -17.1 11/07/2005 01:50:00 3.1 0.6 4.6 1.9 3.1 0.5 4.6 1.5 2.4 0.4 3.4 1.1 129 9 124 255 -17 0 -16.9 -17.2 11/07/2005 02:00:00 3 0.6 4.2 1.5 3.1 0.5 4.6 1.5 2.6 0.5 3.8 1.5 132 10 136 255 -17.4 0 -17.1 -17.6 11/07/2005 02:10:00 2.2 0.5 3.4 0.7 2.3 0.5 3.4 1.1 2 0.5 3 0.4 134 9 130 255 -17.7 0.1 -17.4 -18 11/07/2005 02:20:00 2.6 0.4 3.8 1.5 2.7 0.4 3.4 1.5 2 0.4 2.6 0.7 142 7 134 255 -17.8 0 -17.6 -18 11/07/2005 02:30:00 2.3 0.5 3.4 1.1 2.4 0.4 3.4 1.5 1.8 0.4 3 0.7 146 9 144 255 -17.9 0 -17.8 -18 11/07/2005 02:40:00 3.3 0.5 4.6 2.3 3.3 0.5 4.6 1.9 2.6 0.5 3.8 1.1 135 8 129 255 -18.1 0 -17.8 -18.2 11/07/2005 02:50:00 3.3 0.6 4.9 1.5 3.4 0.7 4.9 1.1 2.6 0.5 4.2 1.1 126 11 138 255 -18.1 0.2 -17.4 -18.4 11/07/2005 03:00:00 2.7 0.5 3.8 1.5 2.8 0.5 4.2 1.5 2.2 0.4 3.4 1.1 140 9 131 255 -17.8 0.1 -17.4 -18 11/07/2005 03:10:00 2.6 0.5 3.8 1.1 2.7 0.5 3.8 1.5 1.9 0.5 3 0.7 143 9 137 255 -18.3 0.1 -18 -18.5 11/07/2005 03:20:00 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.5 1.7 0.4 2.6 0.7 148 10 158 255 -18.6 0 -18.5 -18.9 11/07/2005 03:30:00 3 0.5 4.2 1.1 3.1 0.5 4.2 1.5 2.4 0.5 3.4 1.1 140 9 130 255 -18.9 0 -18.5 -19.1 11/07/2005 03:40:00 2.6 0.5 3.4 1.1 2.8 0.4 3.4 1.1 2.1 0.4 3 1.1 139 9 115 255 -19 0 -18.9 -19.1 11/07/2005 03:50:00 3 0.4 3.8 1.9 3.1 0.4 3.8 1.9 2.2 0.4 3 1.1 146 9 142 255 -19 0 -18.9 -19.1 11/07/2005 04:00:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.1 0.5 3.4 1.1 143 8 131 255 -19.1 0 -18.9 -19.1 11/07/2005 04:10:00 2.2 0.3 3 1.1 2.3 0.3 3 1.5 1.9 0.5 3.4 0.7 143 6 136 255 -19.2 0 -19.1 -19.3 11/07/2005 04:20:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 2 0.4 2.6 1.1 137 7 134 255 -19.4 0 -19.1 -19.6 11/07/2005 04:30:00 1.5 0.5 2.6 0.4 1.6 0.6 3 0.4 1.6 0.5 2.6 0.4 135 8 142 255 -19.5 0.1 -19.1 -19.8 11/07/2005 04:40:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1 0.4 1.9 0.4 141 12 149 255 -19.3 0 -19.1 -19.4 11/07/2005 04:50:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.4 1.9 0.4 146 3 144 255 -19.4 0 -19.3 -19.6 11/07/2005 05:00:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.8 0.3 1.9 0.4 164 21 216 255 -19.4 0.1 -19.3 -19.6 11/07/2005 05:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.5 0.3 2.3 1.1 162 12 177 255 -19.6 0 -19.4 -19.8 11/07/2005 05:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 1.1 0.4 1.9 0.4 161 0 161 255 -19.7 0 -19.6 -19.8 11/07/2005 05:30:00 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.3 0.3 2.3 0.7 155 10 140 255 -19.8 0 -19.6 -20 11/07/2005 05:40:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 1.1 1.6 0.4 2.6 0.7 143 4 144 255 -20.1 0.1 -19.8 -20.3 11/07/2005 05:50:00 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 137 8 136 255 -20.2 0 -20 -20.3 11/07/2005 06:00:00 1.5 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.9 0.3 2.6 1.1 162 10 159 255 -20.2 0.1 -19.8 -20.3 11/07/2005 06:10:00 1.8 0.7 3 0.4 1.9 0.6 3.4 0.4 1.5 0.6 2.6 0.4 188 21 202 255 -19.7 0 -19.4 -19.8 11/07/2005 06:20:00 1.6 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.7 170 30 147 255 -19.9 0 -19.8 -20 11/07/2005 06:30:00 1.4 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.2 0.4 2.3 0.4 162 30 189 255 -20.1 0.1 -19.8 -20.3 11/07/2005 06:40:00 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.5 1.9 0.5 3 0.7 202 22 193 255 -20.3 0 -20.3 -20.3 11/07/2005 06:50:00 2 0.5 3.4 0.7 2.2 0.4 3.4 1.1 1.5 0.5 3 0.7 176 20 148 255 -20.5 0.1 -20.3 -20.7 11/07/2005 07:00:00 1.4 0.5 2.6 0.4 1.8 0.4 2.6 0.7 1.2 0.6 2.3 0.4 176 10 158 255 -20.6 0 -20.3 -20.7 11/07/2005 07:10:00 1.7 0.5 3 0.7 1.9 0.5 3 0.7 1.2 0.5 2.3 0.4 147 15 133 255 -20.5 0 -20.3 -20.7 11/07/2005 07:20:00 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.5 1.9 0.4 149 19 151 255 -20.7 0.1 -20.3 -20.9 11/07/2005 07:30:00 0.6 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 201 58 218 255 -20.8 0 -20.7 -20.9 11/07/2005 07:40:00 0.6 0.5 1.9 0.4 0.6 0.5 2.3 0.4 0.7 0.5 1.9 0.4 217 69 89 255 -20.8 0 -20.5 -20.9 11/07/2005 07:50:00 0.7 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 97 18 100 255 -21.1 0.1 -20.9 -21.2 11/07/2005 08:00:00 0.7 0.7 3 0.4 0.8 0.7 3 0.4 0.7 0.7 3 0.4 47 98 97 255 -21.1 0.1 -20.9 -21.2 11/07/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 73 0 255 255 -20.9 0 -20.7 -21.1 11/07/2005 08:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 317 79 73 255 -21 0 -20.9 -21.1 11/07/2005 08:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 249 24 250 255 -21.1 0.1 -20.9 -21.2 11/07/2005 08:40:00 1.5 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.7 0.9 3.8 0.4 43 86 47 255 -21.3 0 -21.1 -21.4 11/07/2005 08:50:00 0.9 0.6 3 0.4 0.9 0.6 3 0.4 0.6 0.4 2.6 0.4 24 102 22 255 -20.7 0.1 -20.3 -21.1 11/07/2005 09:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 21 69 52 255 -20.8 0 -20.5 -20.9 11/07/2005 09:10:00 0.6 0.5 1.9 0.4 0.6 0.5 1.9 0.4 0.9 0.6 2.6 0.4 24 69 58 255 -20.8 0 -20.5 -20.9 11/07/2005 09:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 80 107 263 255 -20.5 0.2 -20 -20.9 11/07/2005 09:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.6 2.6 0.4 52 76 97 255 -20.3 0 -20.2 -20.3 11/07/2005 09:40:00 0.7 0.6 2.3 0.4 0.7 0.6 2.6 0.4 0.8 0.6 3 0.4 184 64 104 255 -20.1 0.3 -19.1 -20.5 11/07/2005 09:50:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 218 47 196 255 -18.9 0.1 -18.5 -19.1 11/07/2005 10:00:00 0.4 0.2 1.9 0.4 0.4 0.3 1.9 0.4 0.5 0.4 1.9 0.4 304 86 216 255 -18.5 0 -18.4 -18.5 11/07/2005 10:10:00 0.7 0.5 2.6 0.4 0.7 0.6 2.6 0.4 0.7 0.5 2.3 0.4 180 82 232 255 -18.1 0.4 -17.2 -18.5 11/07/2005 10:20:00 1.6 1.4 4.2 0.4 1.7 1.4 4.2 0.4 1.5 1.1 4.2 0.4 305 69 247 255 -17 0.4 -16.5 -17.4 11/07/2005 10:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 340 22 2 255 -16.1 0.4 -15.5 -16.7 11/07/2005 10:40:00 0.7 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0 15 12 255 -15 0.3 -14.6 -15.5 11/07/2005 10:50:00 0.9 0.3 1.5 0.4 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 352 17 12 255 -14.9 0 -14.6 -15 11/07/2005 11:00:00 1.1 0.6 2.3 0.4 1.2 0.6 2.6 0.4 1.2 0.5 2.6 0.4 350 41 42 255 -15 0 -15 -15 11/07/2005 11:10:00 1.1 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 16 22 34 255 -14.8 0 -14.6 -15 11/07/2005 11:20:00 0.7 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 354 24 345 255 -14.4 0.1 -14.2 -14.6 11/07/2005 11:30:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.5 2.6 0.4 338 18 359 255 -14.2 0 -14 -14.4 11/07/2005 11:40:00 1.5 0.5 2.6 0.4 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 351 30 31 255 -14.2 0 -14.2 -14.4 11/07/2005 11:50:00 1.6 0.6 3 0.4 1.7 0.5 3 0.7 1.7 0.6 3 0.4 354 11 358 255 -14.2 0 -14 -14.2 11/07/2005 12:00:00 1.7 0.5 3.4 0.4 1.7 0.4 3 0.4 1.6 0.4 2.6 0.4 330 17 334 255 -14 0.2 -13.6 -14.2 11/07/2005 12:10:00 1.2 0.6 2.3 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.3 0.4 339 28 341 255 -13.4 0.2 -13.2 -13.6 11/07/2005 12:20:00 2.2 0.6 3.4 0.4 2.3 0.5 3.4 0.4 2 0.7 3.4 0.4 341 29 352 255 -13.5 0.2 -13.2 -13.8 11/07/2005 12:30:00 2.2 1 4.2 0.4 2.2 1 4.2 0.4 2 1 4.2 0.4 308 22 300 255 -13.9 0.1 -13.6 -14 11/07/2005 12:40:00 2 0.6 3.8 0.4 2.1 0.6 3.8 0.4 1.6 0.6 3 0.4 310 18 306 255 -14 0 -14 -14 11/07/2005 12:50:00 1.9 0.6 3 0.4 1.9 0.6 3 0.7 1.4 0.7 3.4 0.4 312 11 296 255 -13.8 0 -13.6 -14 11/07/2005 13:00:00 0.8 0.4 1.9 0.4 0.9 0.4 2.3 0.4 1 0.4 1.9 0.4 313 39 280 255 -13.5 0.2 -13.2 -13.8 11/07/2005 13:10:00 0.8 0.5 2.3 0.4 0.8 0.6 2.6 0.4 0.6 0.5 1.9 0.4 285 58 288 255 -12.8 0 -12.6 -13.2 11/07/2005 13:20:00 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 3 27 340 255 -12.5 0 -12.4 -12.6 11/07/2005 13:30:00 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 29 94 70 255 -12.2 0.3 -11.8 -12.6 11/07/2005 13:40:00 0.7 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.8 0.5 1.9 0.4 31 24 28 255 -12.3 0.2 -11.8 -12.6 11/07/2005 13:50:00 0.7 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 4 45 31 255 -12.1 0.2 -11.8 -12.4 11/07/2005 14:00:00 1 0.5 2.3 0.4 1 0.4 2.3 0.4 1 0.5 2.3 0.4 352 28 345 255 -11.8 0.1 -11.6 -12 11/07/2005 14:10:00 1.3 0.7 3 0.4 1.4 0.7 2.6 0.4 1.2 0.6 2.3 0.4 355 13 338 255 -12.1 0.2 -11.8 -12.6 11/07/2005 14:20:00 3.4 1.2 6.5 0.7 3.5 1.2 6.1 0.7 3.3 1.1 6.1 1.1 14 17 17 255 -12.6 0 -12.6 -12.6 11/07/2005 14:30:00 2.8 0.8 4.6 1.1 2.9 0.8 4.9 1.5 2.5 0.9 4.9 0.7 50 10 47 255 -12.8 0 -12.6 -13 11/07/2005 14:40:00 2 0.6 3.4 0.4 2.2 0.6 3.4 0.7 2 0.7 3 0.4 44 15 42 255 -12.7 0.1 -12.6 -13 11/07/2005 14:50:00 1.6 0.4 2.6 0.4 1.8 0.4 3 0.7 1.5 0.5 2.6 0.4 32 20 29 255 -13.1 0 -12.8 -13.4 11/07/2005 15:00:00 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 52 26 34 255 -13.3 0 -13.2 -13.4 11/07/2005 15:10:00 1.3 0.7 3 0.4 1.5 0.7 3 0.4 1.2 0.6 2.6 0.4 61 21 70 255 -13.6 0 -13.4 -13.6 11/07/2005 15:20:00 1.8 0.6 3 0.4 2 0.5 3 0.7 1.7 0.6 3 0.4 58 15 49 255 -13.7 0 -13.6 -13.8 11/07/2005 15:30:00 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.5 1.8 0.4 2.6 0.7 55 9 51 255 -13.9 0 -13.6 -14 11/07/2005 15:40:00 1.3 0.6 2.3 0.4 1.5 0.6 2.6 0.4 1.3 0.6 2.3 0.4 60 22 40 255 -14.1 0 -14 -14.2 11/07/2005 15:50:00 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 29 24 7 255 -14.8 0.2 -14 -15.1 11/07/2005 16:00:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.5 0.3 1.1 0.4 63 9 46 255 -15.5 0.2 -15 -15.9 11/07/2005 16:10:00 0.7 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 61 8 46 255 -16.1 0.1 -15.9 -16.3 11/07/2005 16:20:00 1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 0.8 0.4 1.5 0.4 86 8 94 255 -16.4 0 -16.1 -16.5 11/07/2005 16:30:00 1.1 0.3 1.9 0.4 1.3 0.3 1.9 0.4 0.8 0.3 1.5 0.4 65 7 69 255 -16.8 0.1 -16.5 -17.1 11/07/2005 16:40:00 0.8 0.2 1.5 0.4 1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 65 12 40 255 -17.2 0.1 -17.1 -17.4 11/07/2005 16:50:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 71 0 71 255 -17.4 0 -17.2 -17.6 11/07/2005 17:00:00 0.5 0.2 0.7 0.4 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 71 0 71 255 -17.6 0 -17.4 -17.6 11/07/2005 17:10:00 0.9 0.5 1.9 0.4 1 0.6 1.9 0.4 0.7 0.4 1.9 0.4 79 12 91 255 -17.9 0.1 -17.6 -18 11/07/2005 17:20:00 1.3 0.4 2.3 0.4 1.4 0.5 2.3 0.4 0.8 0.4 1.9 0.4 105 9 105 255 -18.3 0.1 -18 -18.5 11/07/2005 17:30:00 1.8 0.3 2.6 1.1 2 0.3 2.6 1.1 1.1 0.3 1.9 0.4 95 3 88 255 -18.5 0.1 -18.4 -18.5 11/07/2005 17:40:00 1.4 0.4 2.3 0.7 1.5 0.4 2.3 0.7 0.5 0.3 1.5 0.4 83 2 87 255 -18.8 0.1 -18.5 -19.1 11/07/2005 17:50:00 1.7 0.3 2.3 0.7 1.8 0.3 2.3 0.7 0.8 0.3 1.5 0.4 98 7 97 255 -19 0.1 -18.9 -19.1 11/07/2005 18:00:00 1.7 0.3 2.6 1.1 1.8 0.3 2.6 1.1 0.9 0.4 1.9 0.4 98 4 99 255 -19 0 -18.9 -19.1 11/07/2005 18:10:00 1.8 0.2 2.6 1.1 1.9 0.2 2.3 1.5 0.9 0.3 1.5 0.4 93 12 80 255 -19.2 0 -19.1 -19.3 11/07/2005 18:20:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 1.1 0.4 1.9 0.4 96 13 85 255 -19.4 0.1 -19.1 -19.8 11/07/2005 18:30:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 1.6 0.4 2.3 0.4 100 8 119 255 -19.5 0 -19.3 -19.6 11/07/2005 18:40:00 2.2 0.6 3.4 0.7 2.2 0.6 3.4 0.7 1.6 0.5 3 0.7 101 8 104 255 -19.3 0 -19.1 -19.4 11/07/2005 18:50:00 2.6 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2 0.4 3 1.1 91 8 76 255 -19.1 0.1 -18.9 -19.1 11/07/2005 19:00:00 3.7 0.5 5.3 2.6 3.7 0.5 5.3 2.3 2.9 0.5 4.6 1.9 91 8 99 255 -18.4 0.3 -17.6 -18.9 11/07/2005 19:10:00 3.3 0.8 4.9 1.5 3.3 0.7 4.9 1.5 2.6 0.7 4.2 0.7 88 8 86 255 -17.1 0.3 -16.7 -17.6 11/07/2005 19:20:00 3.2 0.7 5.3 1.5 3.2 0.7 5.3 1.1 2.5 0.6 4.2 1.1 85 12 100 255 -16 0.5 -15.3 -16.7 11/07/2005 19:30:00 3.4 0.7 5.7 1.5 3.4 0.8 5.7 1.5 2.8 0.7 4.6 1.1 73 10 83 255 -15.1 0.2 -14.6 -15.3 11/07/2005 19:40:00 3.4 0.9 6.1 1.5 3.5 0.9 6.5 1.9 2.7 0.8 6.1 1.1 72 12 76 255 -14.7 0 -14.6 -14.8 11/07/2005 19:50:00 3.3 0.8 5.7 1.5 3.3 0.8 5.7 1.5 2.6 0.7 4.6 0.7 78 11 81 255 -14.8 0 -14.6 -15 11/07/2005 20:00:00 2.6 0.6 4.2 1.1 2.7 0.5 4.2 1.5 2.1 0.5 3.4 1.1 78 9 93 255 -15.2 0.1 -14.8 -15.3 11/07/2005 20:10:00 2.2 0.7 4.6 1.1 2.3 0.6 4.2 1.1 1.7 0.6 3.4 0.7 84 11 68 255 -15.8 0.2 -15.3 -15.9 11/07/2005 20:20:00 2.5 0.7 4.6 1.1 2.6 0.7 4.6 0.7 2.2 0.8 4.2 0.7 76 14 83 255 -16.1 0.1 -15.9 -16.3 11/07/2005 20:30:00 2.1 0.7 4.6 0.4 2.2 0.6 4.6 0.4 1.8 0.5 3.8 0.4 60 19 65 255 -15.6 0.1 -15.3 -15.9 11/07/2005 20:40:00 1.6 1 5.3 0.4 1.6 1.1 5.7 0.4 1.4 0.8 4.9 0.4 63 18 70 255 -16 0 -15.9 -16.1 11/07/2005 20:50:00 2.2 1.1 5.3 0.4 2.3 1.2 5.3 0.4 1.8 1.1 5.3 0.4 61 27 45 255 -16.1 0 -15.9 -16.1 11/07/2005 21:00:00 2.8 0.9 4.9 1.1 2.9 0.8 4.9 1.1 2.3 0.8 4.9 1.1 75 16 79 255 -15.7 0.1 -15.3 -15.9 11/07/2005 21:10:00 3.7 1.2 6.8 1.1 3.7 1.2 6.8 1.5 3.1 1.1 6.5 1.1 70 17 90 255 -14.9 0.2 -14.6 -15.3 11/07/2005 21:20:00 4.8 1.4 9.1 1.5 4.9 1.4 9.1 1.5 4 1.3 9.1 1.5 83 20 76 255 -14.3 0.1 -14 -14.6 11/07/2005 21:30:00 6 1.5 10.3 2.6 6.1 1.5 10.3 2.6 5.1 1.3 9.1 1.5 88 17 96 255 -13.9 0 -13.8 -14 11/07/2005 21:40:00 5.7 1.7 10.7 0.7 5.9 1.7 10.3 1.9 4.9 1.7 9.5 1.1 84 23 78 255 -13.8 0 -13.6 -14 11/07/2005 21:50:00 5.3 1.9 9.9 1.5 5.4 1.8 9.9 1.9 4.6 1.6 8.8 1.5 84 21 106 255 -13.8 0 -13.6 -14 11/07/2005 22:00:00 6.4 1.8 11.5 1.9 6.5 1.7 12.2 2.6 5.8 1.5 9.9 1.9 78 17 70 255 -13.7 0 -13.6 -14 11/07/2005 22:10:00 6 2.4 11.8 1.1 6.1 2.3 11.8 0.7 5.3 2 11.8 1.5 83 21 90 255 -13.7 0 -13.6 -13.8 11/07/2005 22:20:00 6.3 1.8 11.8 1.9 6.4 1.7 11.1 2.6 5.6 1.7 10.3 2.3 78 20 106 255 -13.7 0 -13.6 -13.6 11/07/2005 22:30:00 5.4 2.2 13 0.7 5.5 2.2 13.3 0.7 4.8 1.8 9.9 0.7 74 20 99 255 -13.7 0 -13.6 -13.8 11/07/2005 22:40:00 5.9 1.8 11.1 1.5 6 1.7 11.1 2.3 5 1.8 11.1 1.1 74 22 50 255 -13.7 0 -13.6 -13.8 11/07/2005 22:50:00 6.8 2.3 13.3 2.6 6.9 2.2 13.3 3 5.7 2.1 11.8 1.5 78 21 81 255 -13.7 0 -13.6 -13.8 11/07/2005 23:00:00 7.9 1.7 11.8 3 7.9 1.7 12.6 3.8 7 1.8 11.1 2.6 82 16 58 255 -13.7 0 -13.6 -13.8 11/07/2005 23:10:00 7.6 2.3 13.7 2.6 7.6 2.3 13.3 3 6.6 2 12.6 0.7 84 17 87 255 -13.8 0 -13.6 -13.8 11/07/2005 23:20:00 7.4 2.1 12.6 1.9 7.3 2.1 12.2 2.3 6.5 2.1 12.6 1.9 83 21 90 255 -13.8 0 -13.6 -13.8 11/07/2005 23:30:00 8.2 2.2 14.1 3.8 8.2 2.2 14.1 3.8 7.2 2.2 13 2.6 92 19 53 255 -13.7 0 -13.6 -13.8 11/07/2005 23:40:00 9 2.9 16.8 3 9 2.8 16.4 3.4 7.7 2.7 15.3 2.6 94 19 88 255 -13.7 0 -13.6 -13.8 11/07/2005 23:50:00 9.4 2.2 14.9 3.4 9.4 2.2 14.5 3.8 7.8 2.3 13.7 2.6 96 18 62 255 -13.7 0 -13.6 -13.6 11/08/2005 00:00:00 9.7 2.5 16.1 3.8 9.7 2.4 15.6 3.8 8.3 2.4 14.9 3 97 20 92 255 -13.7 0 -13.6 -13.8 11/08/2005 00:10:00 9.6 2.5 18.3 3.4 9.6 2.4 17.2 4.2 8.3 2.5 16.1 2.6 96 18 81 255 -13.7 0 -13.6 -13.8 11/08/2005 00:20:00 10.6 2.7 19.5 3.8 10.6 2.5 18.7 4.6 9.3 2.6 15.6 3 99 18 93 255 -13.6 0 -13.4 -13.6 11/08/2005 00:30:00 10.7 2.7 18.3 4.9 10.8 2.6 17.9 4.2 9.3 2.6 17.6 3.8 102 18 94 255 -13.4 0 -13.4 -13.6 11/08/2005 00:40:00 10.1 2.6 18.7 4.2 10.2 2.4 18.7 4.2 8.7 2.4 16.1 2.6 102 18 130 255 -13.4 0 -13.2 -13.6 11/08/2005 00:50:00 10 2.7 16.8 4.2 10 2.6 16.8 4.2 8.4 2.5 14.5 3 106 21 86 255 -13.3 0 -13.2 -13.4 11/08/2005 01:00:00 9.9 2.4 17.9 3.8 9.9 2.4 17.6 4.6 8.7 2.2 16.4 3.4 100 16 89 255 -13.2 0 -13.2 -13.4 11/08/2005 01:10:00 9.8 2.1 15.3 4.6 9.8 2.1 14.9 4.6 8.3 2.2 14.9 3.8 103 17 103 255 -13.2 0 -13.2 -13.2 11/08/2005 01:20:00 9.2 2.7 16.4 2.6 9.2 2.6 15.3 2.3 8 2.5 14.5 2.3 99 17 88 255 -13.1 0 -13.2 -13.2 11/08/2005 01:30:00 8.7 2.4 14.9 2.6 8.8 2.4 14.9 3 7.6 2.4 13.7 3 95 20 112 255 -13.1 0 -13.2 -13.2 11/08/2005 01:40:00 7.4 2.1 13.3 1.5 7.5 2.1 13.3 1.5 6.3 1.9 11.1 1.5 88 22 93 255 -13.1 0 -13.2 -13.2 11/08/2005 01:50:00 7.6 2.1 13.7 3.8 7.7 2.1 13.3 3.8 7 1.9 12.2 2.6 90 17 79 255 -13.1 0 -13 -13.2 11/08/2005 02:00:00 7.9 2.6 15.6 2.6 7.9 2.6 14.9 3 6.7 2.5 14.1 2.6 91 21 106 255 -12.9 0.1 -12.6 -13.2 11/08/2005 02:10:00 7.8 2.2 14.9 3 7.9 2.2 14.9 2.6 6.7 2.2 13.3 1.5 90 21 97 255 -12.9 0 -12.6 -13 11/08/2005 02:20:00 7.4 1.7 12.2 3 7.5 1.7 11.8 3 6.4 1.8 11.1 1.9 93 18 83 255 -13 0 -12.8 -13.2 11/08/2005 02:30:00 8 2.2 14.1 2.6 8 2.2 14.1 2.3 6.8 2.2 13.7 1.5 88 19 111 255 -12.9 0 -12.8 -13 11/08/2005 02:40:00 7.6 2.6 15.6 1.9 7.7 2.6 16.4 2.3 6.7 2.4 13.7 1.1 89 20 56 255 -12.9 0 -12.8 -13 11/08/2005 02:50:00 7.8 2.2 13.3 2.3 7.8 2.2 14.1 3.4 6.9 2.1 12.6 1.9 87 20 93 255 -12.7 0 -12.6 -12.8 11/08/2005 03:00:00 8.8 2 13.7 3 8.9 1.9 14.1 3.8 7.5 1.8 12.6 2.6 92 19 108 255 -12.7 0 -12.6 -12.8 11/08/2005 03:10:00 7.4 2.2 13 3 7.5 2 13.3 2.6 6.5 2 12.2 2.3 88 20 89 255 -12.6 0 -12.6 -12.6 11/08/2005 03:20:00 7.2 2.3 14.9 2.3 7.4 2.2 14.9 3 6.1 2.1 13 2.3 91 22 70 255 -12.5 0 -12.4 -12.6 11/08/2005 03:30:00 8.2 2.2 16.1 3.8 8.3 2.1 16.1 4.2 6.9 2.1 14.5 2.3 92 17 88 255 -12.4 0 -12.2 -12.6 11/08/2005 03:40:00 8.5 2.2 14.1 2.6 8.5 2.2 14.1 2.6 7.3 2.1 13.3 3 94 17 109 255 -12.2 0 -12.2 -12.2 11/08/2005 03:50:00 7.5 1.9 13 3 7.6 1.8 12.6 1.9 6.4 2 12.2 1.5 90 20 99 255 -12.2 0 -12.2 -12.2 11/08/2005 04:00:00 5.5 1.7 9.9 2.3 5.6 1.6 9.9 2.3 5.1 1.5 9.1 2.3 74 22 133 255 -12.2 0 -12.2 -12.2 11/08/2005 04:10:00 5.7 1.5 9.9 1.9 5.8 1.5 9.9 1.9 5 1.4 8.8 1.9 69 22 54 255 -12.3 0 -12.2 -12.2 11/08/2005 04:20:00 5.9 1.7 12.6 2.6 6 1.7 12.6 2.3 5 1.7 12.6 1.9 77 21 78 255 -12.1 0 -12 -12.2 11/08/2005 04:30:00 5.9 1.7 11.8 1.9 6 1.7 11.5 0.7 5.3 1.7 9.9 0.7 72 21 86 255 -12.1 0 -12 -12.2 11/08/2005 04:40:00 6.5 1.8 11.8 2.6 6.6 1.8 11.8 2.6 5.8 1.5 10.3 2.6 75 18 75 255 -12.2 0 -12 -12.2 11/08/2005 04:50:00 7.1 1.9 12.6 3.4 7.2 1.8 11.8 3.4 6.4 1.7 11.5 2.6 76 19 106 255 -12.3 0 -12.2 -12.4 11/08/2005 05:00:00 7 1.7 11.1 2.3 7 1.6 11.1 3 6.2 2 11.1 1.1 78 17 83 255 -12.4 0 -12.2 -12.4 11/08/2005 05:10:00 7.8 1.8 13 3.4 7.9 1.7 13.3 3.8 6.7 1.7 11.8 3 81 16 81 255 -12.3 0 -12.2 -12.4 11/08/2005 05:20:00 7.2 1.7 12.2 3 7.3 1.7 12.2 3 6.3 1.7 11.1 1.5 80 15 94 255 -12.4 0 -12.2 -12.4 11/08/2005 05:30:00 6.1 1.7 10.3 1.9 6.2 1.7 10.7 3 5.1 1.6 9.5 1.9 78 22 93 255 -12.4 0 -12.2 -12.6 11/08/2005 05:40:00 6.8 1.9 10.7 2.6 6.8 1.9 11.5 2.3 5.7 1.8 11.5 1.1 81 18 100 255 -12.4 0 -12.2 -12.4 11/08/2005 05:50:00 7.2 1.9 12.6 3 7.2 1.9 12.6 3 6.1 1.8 11.1 1.9 80 18 112 255 -12.4 0 -12.2 -12.4 11/08/2005 06:00:00 7.3 1.7 11.8 2.3 7.3 1.6 11.5 2.3 6.3 1.7 10.7 1.9 79 15 74 255 -12.4 0 -12.2 -12.4 11/08/2005 06:10:00 6.6 1.5 10.7 2.6 6.6 1.5 10.7 3 5.8 1.5 10.3 2.6 86 17 97 255 -12.3 0 -12.2 -12.4 11/08/2005 06:20:00 5.3 1.3 8.8 1.9 5.4 1.2 8.4 2.3 4.6 1.2 8.8 1.9 83 18 76 255 -12.2 0 -12.2 -12.2 11/08/2005 06:30:00 5 1.3 8 1.9 5.1 1.3 8.8 2.3 4.4 1.1 7.2 1.9 82 15 93 255 -12.1 0 -12 -12.2 11/08/2005 06:40:00 4.2 1.2 7.6 1.5 4.3 1.2 7.6 1.5 3.8 1.2 7.2 1.1 80 20 91 255 -12.2 0 -12 -12.2 11/08/2005 06:50:00 3.9 1.1 7.6 1.1 3.9 1.1 8 1.5 3.7 1 6.5 1.5 82 17 61 255 -12.3 0 -12.2 -12.2 11/08/2005 07:00:00 4.4 1.2 7.6 0.7 4.5 1.2 7.6 1.1 3.9 1.1 6.5 1.5 86 17 95 255 -12.2 0 -12 -12.2 11/08/2005 07:10:00 3.3 1.3 6.8 1.1 3.4 1.2 6.5 1.1 2.9 1.1 7.2 1.1 62 23 76 255 -12.2 0.2 -12 -12.6 11/08/2005 07:20:00 2 0.4 3 0.7 2.2 0.4 3.4 1.1 2 0.4 3 1.1 23 13 42 255 -13.1 0.2 -12.6 -13.4 11/08/2005 07:30:00 1.4 0.6 3.4 0.4 1.7 0.5 3.4 0.7 1.5 0.4 2.6 0.4 25 18 44 255 -13.5 0.1 -13.2 -13.6 11/08/2005 07:40:00 1.6 0.4 2.6 0.7 1.8 0.3 3.4 1.1 1.7 0.3 2.6 0.7 17 9 42 255 -13.6 0 -13.4 -13.6 11/08/2005 07:50:00 0.8 0.5 1.9 0.4 1.2 0.4 2.3 0.4 0.9 0.3 1.5 0.4 25 17 15 255 -13.7 0 -13.6 -13.8 11/08/2005 08:00:00 0.5 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 54 16 67 255 -13.7 0 -13.6 -13.8 11/08/2005 08:10:00 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 4 17 2 255 -13.8 0 -13.6 -13.8 11/08/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 324 0 255 255 -13.8 0 -13.8 -14 11/08/2005 08:30:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 337 23 325 255 -13.9 0 -13.8 -14 11/08/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 294 0 255 255 -13.8 0 -13.6 -14 11/08/2005 08:50:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 294 0 255 255 -13.7 0 -13.6 -13.8 11/08/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 294 0 255 255 -13.7 0 -13.6 -13.6 11/08/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 255 255 -13.5 0.1 -13.4 -13.6 11/08/2005 09:20:00 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 295 0 294 255 -13.3 0 -13.2 -13.6 11/08/2005 09:30:00 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 285 16 252 255 -13.1 0 -13 -13.2 11/08/2005 09:40:00 0.8 0.5 1.9 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.5 0.4 269 12 267 255 -12.9 0 -12.6 -13.2 11/08/2005 09:50:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 293 14 271 255 -12.6 0 -12.4 -12.6 11/08/2005 10:00:00 1.1 0.8 2.6 0.4 1.3 0.8 3 0.4 1.2 0.7 3 0.4 316 12 317 255 -12.4 0 -12.2 -12.6 11/08/2005 10:10:00 0.6 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.9 0.5 1.9 0.4 337 19 305 255 -12.3 0 -12 -12.4 11/08/2005 10:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 319 29 313 255 -12 0 -11.8 -12.2 11/08/2005 10:30:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 334 14 355 255 -11.9 0 -11.8 -12 11/08/2005 10:40:00 0.8 0.5 1.9 0.4 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 322 27 329 255 -11.9 0 -11.8 -12 11/08/2005 10:50:00 0.5 0.2 1.9 0.4 0.6 0.3 1.9 0.4 0.7 0.4 1.5 0.4 323 17 316 255 -11.6 0.1 -11.4 -11.8 11/08/2005 11:00:00 0.6 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.4 2.3 0.4 315 14 320 255 -11.5 0 -11.4 -11.6 11/08/2005 11:10:00 0.9 0.5 1.9 0.4 0.9 0.4 1.9 0.4 1.4 0.4 2.3 0.4 349 12 0 255 -11.5 0 -11.4 -11.4 11/08/2005 11:20:00 0.7 0.4 1.9 0.4 0.8 0.4 2.3 0.4 1.1 0.5 2.3 0.4 332 15 345 255 -11.4 0 -11.2 -11.4 11/08/2005 11:30:00 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 302 26 292 255 -11.1 0 -11 -11.4 11/08/2005 11:40:00 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.6 0.4 304 11 294 255 -11 0 -11 -11.2 11/08/2005 11:50:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 321 12 319 255 -10.9 0 -10.8 -11 11/08/2005 12:00:00 0.4 0.1 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.3 1.5 0.4 300 15 291 255 -10.8 0 -10.6 -11 11/08/2005 12:10:00 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 1 0.3 1.9 0.4 308 12 301 255 -10.5 0 -10.4 -10.6 11/08/2005 12:20:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.5 0.4 2.6 0.4 346 10 345 255 -10.4 0 -10.4 -10.6 11/08/2005 12:30:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1 0.6 2.3 0.4 330 14 340 255 -10.4 0 -10.2 -10.4 11/08/2005 12:40:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 338 9 342 255 -10.3 0 -10.2 -10.4 11/08/2005 12:50:00 0.9 0.6 2.3 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 341 24 358 255 -10.3 0 -10.2 -10.4 11/08/2005 13:00:00 1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 1.3 0.5 2.6 0.4 320 17 313 255 -10.1 0 -10 -10.2 11/08/2005 13:10:00 1 0.5 2.6 0.4 1 0.5 2.6 0.4 1.2 0.5 2.3 0.4 333 16 323 255 -10.1 0 -10 -10.2 11/08/2005 13:20:00 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 343 22 349 255 -9.9 0 -9.7 -10.2 11/08/2005 13:30:00 1.3 0.4 2.3 0.4 1.3 0.4 2.6 0.4 1.6 0.3 2.3 0.7 351 13 0 255 -10 0 -9.7 -10.2 11/08/2005 13:40:00 1.3 0.6 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.5 2.6 0.4 342 14 350 255 -9.8 0 -9.7 -10 11/08/2005 13:50:00 1.7 0.5 3 0.4 1.7 0.5 2.6 0.4 1.7 0.5 3 0.4 343 9 338 255 -9.4 0.1 -9.1 -9.7 11/08/2005 14:00:00 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 334 27 3 255 -9.3 0 -9.1 -9.3 11/08/2005 14:10:00 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.6 0.5 3 0.4 299 20 309 255 -9.5 0 -9.3 -9.7 11/08/2005 14:20:00 1.1 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.5 0.5 2.6 0.4 328 21 337 255 -9.5 0 -9.3 -9.7 11/08/2005 14:30:00 1.4 0.7 3.4 0.4 1.6 0.6 3.4 0.4 1.6 0.5 2.6 0.4 355 22 14 255 -9.6 0 -9.5 -9.7 11/08/2005 14:40:00 1.9 0.5 3 0.4 2.2 0.4 3 1.1 2.2 0.5 3 1.1 357 10 358 255 -9.8 0 -9.7 -10 11/08/2005 14:50:00 1.2 0.7 2.3 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 351 13 323 255 -10.1 0.1 -9.7 -10.4 11/08/2005 15:00:00 0.8 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.3 0.5 2.3 0.4 353 9 358 255 -10.4 0 -10.2 -10.6 11/08/2005 15:10:00 1 0.5 1.9 0.4 1.1 0.4 2.3 0.4 1.3 0.5 2.3 0.4 339 14 339 255 -10.6 0 -10.4 -10.6 11/08/2005 15:20:00 1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1 13 14 255 -10.8 0.1 -10.6 -11 11/08/2005 15:30:00 1.4 0.3 2.3 0.7 1.7 0.2 2.3 1.1 1.8 0.3 2.3 0.7 15 12 3 255 -10.9 0 -10.8 -11 11/08/2005 15:40:00 1.1 0.3 1.9 0.4 1.5 0.2 1.9 1.1 1.5 0.3 2.3 0.4 24 8 31 255 -11 0 -11 -11.2 11/08/2005 15:50:00 0.6 0.4 1.5 0.4 0.9 0.4 1.9 0.4 1.1 0.5 1.9 0.4 16 4 12 255 -11.1 0 -11 -11.2 11/08/2005 16:00:00 0.7 0.4 1.9 0.4 1.2 0.3 1.9 0.4 1.2 0.3 2.3 0.4 20 8 17 255 -11.1 0 -11 -11.2 11/08/2005 16:10:00 1.2 0.4 1.9 0.4 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 14 8 354 255 -11.1 0 -11 -11.2 11/08/2005 16:20:00 1.4 0.5 2.3 0.4 1.6 0.4 2.6 0.4 1.7 0.5 2.6 0.7 25 9 24 255 -11.2 0 -11 -11.4 11/08/2005 16:30:00 1.3 0.4 2.3 0.4 1.5 0.3 2.3 0.4 1.5 0.4 2.3 0.4 34 13 16 255 -11.3 0 -11.2 -11.4 11/08/2005 16:40:00 0.9 0.5 1.9 0.4 1.3 0.4 2.3 0.4 1.2 0.4 1.9 0.4 36 11 19 255 -11.4 0 -11.2 -11.4 11/08/2005 16:50:00 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 49 8 34 255 -11.5 0 -11.4 -11.4 11/08/2005 17:00:00 1 0.6 2.3 0.4 1.4 0.5 2.3 0.4 1.5 0.4 2.3 0.4 25 10 23 255 -11.5 0 -11.4 -11.6 11/08/2005 17:10:00 1.8 0.4 2.6 0.7 2 0.4 3 1.1 1.9 0.3 2.6 1.1 23 9 23 255 -11.6 0 -11.6 -11.8 11/08/2005 17:20:00 1.2 0.6 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 30 14 30 255 -11.7 0 -11.6 -11.8 11/08/2005 17:30:00 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 41 7 37 255 -11.9 0 -11.8 -12 11/08/2005 17:40:00 0.8 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1 0.3 1.9 0.4 48 11 30 255 -12 0 -12 -12.2 11/08/2005 17:50:00 0.7 0.5 2.6 0.4 1 0.6 3 0.4 0.9 0.4 2.6 0.4 49 15 43 255 -12.1 0 -12 -12.2 11/08/2005 18:00:00 1.2 0.5 2.3 0.4 1.5 0.4 2.6 0.7 1.4 0.4 2.3 0.4 40 13 46 255 -12.3 0 -12.2 -12.2 11/08/2005 18:10:00 0.7 0.5 1.9 0.4 1 0.5 2.3 0.4 1 0.4 1.9 0.4 39 16 10 255 -12.3 0 -12.2 -12.4 11/08/2005 18:20:00 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.4 2.3 0.4 47 14 42 255 -12.6 0 -12.4 -12.6 11/08/2005 18:30:00 1.2 0.5 2.3 0.4 1.5 0.4 2.6 0.4 1.3 0.5 2.3 0.4 38 9 38 255 -12.6 0 -12.6 -12.6 11/08/2005 18:40:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 24 3 24 255 -12.9 0.2 -12.6 -13.2 11/08/2005 18:50:00 0.4 0.3 1.5 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 33 17 68 255 -13.5 0.1 -13.2 -13.6 11/08/2005 19:00:00 1.3 0.4 2.6 0.4 1.6 0.3 2.6 1.1 1.2 0.3 2.3 0.4 52 9 40 255 -13.7 0 -13.6 -13.8 11/08/2005 19:10:00 1.3 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1 0.5 2.6 0.4 53 13 49 255 -13.8 0 -13.6 -14 11/08/2005 19:20:00 0.8 0.6 2.3 0.4 1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 65 15 79 255 -13.9 0 -13.8 -14 11/08/2005 19:30:00 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 0.9 0.4 1.9 0.4 62 13 74 255 -13.8 0 -13.8 -14 11/08/2005 19:40:00 1.5 0.4 2.3 0.4 1.8 0.4 2.6 0.7 1.3 0.4 2.3 0.4 38 9 34 255 -13.7 0.1 -13.4 -14 11/08/2005 19:50:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 42 11 39 255 -13.4 0 -13.2 -13.6 11/08/2005 20:00:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 48 15 92 255 -13.3 0 -13.2 -13.4 11/08/2005 20:10:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 71 24 64 255 -13 0 -12.8 -13.2 11/08/2005 20:20:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 79 30 42 255 -12.6 0.1 -12.4 -12.8 11/08/2005 20:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 67 29 35 255 -12.2 0.1 -12 -12.4 11/08/2005 20:40:00 0.8 0.6 2.3 0.4 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 47 20 25 255 -11.9 0.1 -11.8 -12 11/08/2005 20:50:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 33 9 40 255 -11.7 0 -11.6 -11.8 11/08/2005 21:00:00 0.5 0.3 1.5 0.4 0.5 0.4 1.5 0.4 0.6 0.3 1.5 0.4 48 19 49 255 -11.6 0 -11.4 -11.8 11/08/2005 21:10:00 1 0.6 2.3 0.4 1.2 0.7 2.6 0.4 1.1 0.6 2.6 0.4 45 27 20 255 -11.5 0 -11.2 -11.6 11/08/2005 21:20:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.3 1.5 0.4 28 7 31 255 -11.2 0 -11 -11.4 11/08/2005 21:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 75 7 68 255 -11 0 -11 -11.2 11/08/2005 21:40:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.3 1.5 0.4 40 12 36 255 -10.9 0 -10.8 -11 11/08/2005 21:50:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 31 11 40 255 -10.8 0 -10.6 -10.8 11/08/2005 22:00:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 39 11 23 255 -10.7 0 -10.6 -10.8 11/08/2005 22:10:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 1 0.3 1.5 0.4 43 13 31 255 -10.6 0 -10.6 -10.8 11/08/2005 22:20:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 19 1 21 255 -10.5 0 -10.4 -10.6 11/08/2005 22:30:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 19 0 19 255 -10.4 0 -10.4 -10.6 11/08/2005 22:40:00 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.1 0.4 1.9 0.4 5 11 346 255 -10.4 0 -10.4 -10.6 11/08/2005 22:50:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 15 9 10 255 -10.5 0 -10.4 -10.6 11/08/2005 23:00:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.9 0.4 1.5 0.4 28 13 8 255 -10.6 0 -10.4 -10.6 11/08/2005 23:10:00 0.5 0.3 1.9 0.4 0.6 0.3 1.9 0.4 0.8 0.4 1.9 0.4 21 1 20 255 -10.8 0.1 -10.6 -11 11/08/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 6 3 255 255 -11.1 0.1 -11 -11.4 11/08/2005 23:30:00 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.8 0.3 1.5 0.4 348 17 346 255 -11.5 0 -11.4 -11.6 11/08/2005 23:40:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.5 0.4 10 17 23 255 -11.7 0 -11.6 -11.8 11/08/2005 23:50:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 40 9 23 255 -11.7 0 -11.4 -11.8 11/09/2005 00:00:00 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 51 3 49 255 -11.7 0 -11.4 -11.8 11/09/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 0 255 255 -11.8 0 -11.6 -11.8 11/09/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 0 255 255 -11.9 0 -11.8 -12 11/09/2005 00:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 344 24 255 255 -12 0 -11.8 -12.2 11/09/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 335 0 255 255 -12.3 0 -12.2 -12.6 11/09/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 335 0 255 255 -12.6 0 -12.4 -12.6 11/09/2005 01:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 20 38 78 255 -12.8 0.1 -12.6 -13 11/09/2005 01:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.9 0.4 77 0 255 255 -13.1 0 -12.8 -13.2 11/09/2005 01:20:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 86 12 102 255 -13.5 0.1 -13.2 -13.6 11/09/2005 01:30:00 0.4 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 52 27 51 255 -13.7 0 -13.6 -13.6 11/09/2005 01:40:00 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 46 16 19 255 -13.6 0 -13.4 -13.6 11/09/2005 01:50:00 1.2 0.6 2.3 0.4 1.5 0.5 2.3 0.4 0.9 0.4 1.9 0.4 25 11 20 255 -13.4 0 -13.4 -13.6 11/09/2005 02:00:00 0.8 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 57 22 42 255 -13.6 0 -13.4 -13.8 11/09/2005 02:10:00 0.7 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 58 11 80 255 -13.7 0 -13.6 -13.8 11/09/2005 02:20:00 0.9 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.6 0.3 1.1 0.4 50 13 62 255 -13.7 0 -13.6 -13.8 11/09/2005 02:30:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 61 10 60 255 -13.7 0 -13.6 -13.8 11/09/2005 02:40:00 0.4 0.1 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 0.7 0.4 48 41 32 255 -13.7 0 -13.6 -13.6 11/09/2005 02:50:00 1.3 0.6 3 0.4 1.5 0.6 3 0.4 0.9 0.4 1.9 0.4 28 22 27 255 -13.6 0 -13.2 -13.6 11/09/2005 03:00:00 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 35 17 39 255 -13.3 0 -13.2 -13.4 11/09/2005 03:10:00 0.8 0.5 2.3 0.4 1.1 0.4 2.3 0.4 0.9 0.3 1.5 0.4 35 6 32 255 -13.1 0 -13.2 -13.4 11/09/2005 03:20:00 0.7 0.5 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.4 1.9 0.4 64 29 14 255 -13 0 -12.8 -13.2 11/09/2005 03:30:00 0.6 0.6 2.6 0.4 0.8 0.6 3 0.4 0.7 0.5 2.3 0.4 39 30 14 255 -12.9 0 -12.6 -13.2 11/09/2005 03:40:00 0.7 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.5 1.9 0.4 15 27 30 255 -13.1 0 -13 -13.2 11/09/2005 03:50:00 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 55 14 48 255 -13.1 0 -13.2 -13.2 11/09/2005 04:00:00 0.7 0.4 1.9 0.4 1 0.5 1.9 0.4 0.8 0.3 1.5 0.4 37 33 354 255 -13.1 0 -12.8 -13.2 11/09/2005 04:10:00 1.1 0.6 3 0.4 1.4 0.6 3.4 0.4 0.9 0.5 2.6 0.4 42 28 2 255 -12.8 0 -12.6 -13 11/09/2005 04:20:00 0.4 0.3 1.9 0.4 0.5 0.4 2.3 0.4 0.5 0.2 1.5 0.4 29 14 69 255 -12.4 0 -12.2 -12.6 11/09/2005 04:30:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 352 38 295 255 -12 0 -11.8 -12.2 11/09/2005 04:40:00 0.9 0.7 3.8 0.4 1.1 0.7 3 0.4 1.1 0.6 2.6 0.4 44 41 350 255 -11.7 0 -11.4 -11.8 11/09/2005 04:50:00 0.8 0.7 3.8 0.4 1 0.7 3.8 0.4 0.7 0.4 1.9 0.4 4 22 330 255 -11.6 0 -11.4 -11.8 11/09/2005 05:00:00 1.1 0.6 3.4 0.4 1.1 0.6 3.4 0.4 1 0.5 2.3 0.4 350 15 22 255 -11.8 0 -11.8 -11.8 11/09/2005 05:10:00 2.3 0.7 3.8 0.7 2.5 0.6 4.2 1.1 2.1 0.6 3.4 0.7 53 23 63 255 -11.9 0 -11.8 -12 11/09/2005 05:20:00 1.4 0.8 3.8 0.4 1.6 0.7 3.4 0.4 1.2 0.6 3.4 0.4 55 22 113 255 -11.8 0 -11.6 -11.8 11/09/2005 05:30:00 4 1.5 9.1 1.1 4 1.5 9.1 1.1 3.1 1.3 8.4 0.4 65 30 75 255 -11.2 0.6 -10.4 -11.8 11/09/2005 05:40:00 3.7 0.9 6.8 1.5 3.8 0.9 7.6 1.9 3 0.6 5.3 1.9 47 20 70 255 -11 0.2 -10.6 -11.4 11/09/2005 05:50:00 3.1 0.8 6.1 1.1 3.2 0.8 6.8 1.9 2.7 0.6 5.3 1.1 20 22 98 255 -10.8 0 -10.8 -11 11/09/2005 06:00:00 2.7 1.4 7.2 0.4 2.7 1.4 8 0.4 2.1 1.2 7.6 0.4 45 39 92 255 -10.8 0.2 -10 -11 11/09/2005 06:10:00 3.9 0.9 7.2 1.5 3.9 0.9 6.8 2.3 3.2 0.6 5.3 1.5 47 20 84 255 -9.6 0.3 -9.1 -10.2 11/09/2005 06:20:00 2.6 0.8 5.7 1.1 2.6 0.7 5.7 1.1 2.2 0.7 3.8 0.7 11 18 27 255 -10.4 0 -10.2 -10.6 11/09/2005 06:30:00 3.3 1.3 7.6 0.4 3.2 1.2 8 0.4 2.6 0.9 6.8 0.7 44 29 86 255 -10.3 0.1 -9.7 -10.6 11/09/2005 06:40:00 4.4 1.5 9.1 1.5 4.5 1.5 9.9 1.9 3.6 1.5 9.9 1.1 52 24 69 255 -9.2 0.6 -7.9 -9.7 11/09/2005 06:50:00 5.9 2.1 12.2 1.1 6 2.1 11.8 1.1 4.9 1.7 10.3 1.1 61 26 116 255 -7.1 0.4 -6.6 -8.1 11/09/2005 07:00:00 4.5 1.1 9.1 1.9 4.6 1.2 9.5 1.9 3.8 0.9 7.6 1.9 39 22 64 255 -8.1 0.6 -6.8 -8.7 11/09/2005 07:10:00 4.3 1 8.4 1.5 4.3 1.1 8.8 1.5 3.5 1 8 1.5 40 20 57 255 -8.5 0.2 -8.1 -8.9 11/09/2005 07:20:00 3.1 0.8 5.3 1.5 3.2 0.8 5.7 1.5 2.6 0.9 4.9 1.1 21 12 27 255 -9.2 0 -8.9 -9.3 11/09/2005 07:30:00 3.2 0.7 4.9 1.9 3.3 0.6 5.3 1.9 2.5 0.6 4.2 1.1 52 15 44 255 -9.1 0.2 -8.5 -9.3 11/09/2005 07:40:00 2.9 1 6.1 1.1 3 0.9 6.5 1.5 2.3 0.8 5.3 0.7 29 17 57 255 -8.7 0 -8.5 -8.9 11/09/2005 07:50:00 3.5 1.1 7.6 1.5 3.6 1 8 1.5 3 1 6.5 1.1 45 20 69 255 -8.5 0.1 -8.1 -8.9 11/09/2005 08:00:00 5 1.9 13.3 1.1 5.2 2 13.3 1.5 4.1 1.7 9.5 1.5 61 22 65 255 -7.7 0.4 -6.6 -8.1 11/09/2005 08:10:00 5.5 1.5 10.3 1.9 5.6 1.5 10.3 2.3 4.7 1.3 8.4 1.9 64 21 51 255 -5.9 0.5 -4.8 -6.8 11/09/2005 08:20:00 6.2 2 12.2 2.6 6.3 2.1 13 1.9 5.5 1.7 10.3 2.3 66 22 68 255 -4.5 0.2 -4.2 -5 11/09/2005 08:30:00 5.2 1.5 11.1 1.5 5.2 1.7 11.5 1.1 4.5 1.3 8.4 1.5 58 22 86 255 -5.7 0.3 -5 -6.1 11/09/2005 08:40:00 5.1 1.7 11.1 1.5 5.1 1.7 10.3 1.5 4.4 1.6 9.5 1.1 63 32 106 255 -6.4 0.3 -5.7 -7 11/09/2005 08:50:00 4.1 1.8 11.1 0.7 4.2 1.9 11.5 0.4 3.6 1.5 9.9 1.5 50 32 106 255 -6.6 0.6 -5.7 -7.6 11/09/2005 09:00:00 4.4 1.6 8 0.4 4.6 1.5 8.8 1.9 3.5 1.2 8 1.1 51 30 93 255 -8.1 0.2 -7.4 -8.3 11/09/2005 09:10:00 6.4 2.2 12.2 2.3 6.6 2.2 12.2 2.6 5.6 2 11.1 1.9 76 24 71 255 -6.3 1.3 -4.4 -7.9 11/09/2005 09:20:00 8 2.5 13.7 1.5 8 2.4 13.3 2.6 7.2 2.1 12.6 0.7 82 20 69 255 -3.7 0.2 -3.3 -4.4 11/09/2005 09:30:00 6.6 1.7 11.1 3 6.7 1.8 11.8 3 5.7 1.7 11.5 1.9 81 23 109 255 -3.8 0.4 -3.3 -4.6 11/09/2005 09:40:00 5.7 2 11.8 1.9 5.7 2 11.8 1.5 5.3 1.7 9.9 2.3 70 22 87 255 -4.2 0.7 -3.3 -5.5 11/09/2005 09:50:00 6.7 2.4 14.9 0.4 6.8 2.4 14.5 0.7 5.7 2.3 13 1.1 86 23 102 255 -4.7 0.9 -3.3 -5.9 11/09/2005 10:00:00 8.9 2.4 15.3 3.4 9 2.3 14.9 3 7.6 2.3 13.3 2.6 92 17 80 255 -3.3 0 -3.3 -3.5 11/09/2005 10:10:00 6.9 2.3 14.1 2.3 7.1 2.1 14.1 2.6 5.8 2 12.2 2.3 74 23 62 255 -3.3 0 -3 -3.3 11/09/2005 10:20:00 8.6 2.2 13.7 3 8.7 2.2 13.7 3.4 7.6 2.1 12.6 3 72 16 76 255 -3.1 0 -3 -3.3 11/09/2005 10:30:00 8.3 2.2 13.7 3.4 8.5 2.2 13.3 3.4 7.3 2.2 13.3 2.3 77 16 73 255 -3.1 0 -2.8 -3.3 11/09/2005 10:40:00 7.8 1.8 12.6 3.8 7.9 1.8 12.6 3.4 6.7 1.9 12.6 2.6 74 16 76 255 -2.8 0 -2.6 -3 11/09/2005 10:50:00 7.3 2.2 12.2 1.9 7.3 2.2 12.6 2.3 6.6 1.8 11.8 3 80 19 92 255 -2.8 0 -2.6 -2.8 11/09/2005 11:00:00 6.9 2.6 13 0.4 7 2.5 12.6 1.5 6.1 2.5 11.8 0.7 81 23 61 255 -2.9 0 -2.8 -3 11/09/2005 11:10:00 8 2.2 13.7 3.8 8 2.2 13.7 3.8 6.9 2.1 12.2 2.6 78 20 83 255 -2.7 0 -2.6 -2.8 11/09/2005 11:20:00 8 2.1 13.3 3.8 8 2 13 3 6.9 2.2 12.6 2.6 79 18 75 255 -2.4 0 -2.1 -2.6 11/09/2005 11:30:00 7.2 1.9 12.6 3 7.2 1.9 12.6 2.6 6.2 1.9 13 2.3 78 17 81 255 -2.2 0 -2.1 -2.4 11/09/2005 11:40:00 8.1 2.1 13.7 2.3 8.1 2 13.7 3 7.2 2.1 12.2 2.6 82 17 80 255 -2.1 0 -2.1 -2.1 11/09/2005 11:50:00 8.2 1.7 12.6 4.2 8.2 1.7 11.8 3.4 7.2 1.7 11.8 3.4 81 17 74 255 -2.2 0.1 -2.1 -2.6 11/09/2005 12:00:00 7.2 2.3 13.7 2.6 7.3 2.3 13.3 3 6.5 2.4 13 2.6 83 20 82 255 -2.4 0 -2.1 -2.6 11/09/2005 12:10:00 8.6 2.4 15.6 2.3 8.7 2.4 16.1 2.6 7.5 2.2 14.5 3.4 92 18 94 255 -2.1 0 -2.1 -2.1 11/09/2005 12:20:00 8.7 2.1 14.1 3.8 8.7 2.1 13.7 3.4 7.6 2 12.6 1.5 88 17 85 255 -2 0 -1.9 -2.1 11/09/2005 12:30:00 9 2.2 14.9 3 9.2 2.1 14.1 3.4 7.9 2 13 3 91 18 97 255 -1.7 0 -1.4 -1.9 11/09/2005 12:40:00 8.7 2.4 15.6 3 8.7 2.3 16.1 4.2 7.4 2.3 13.7 2.6 89 18 70 255 -1.5 0 -1.4 -1.4 11/09/2005 12:50:00 8.4 2.3 14.5 3.4 8.6 2.1 14.9 3.8 7.3 2.1 13.3 2.6 91 20 88 255 -1.5 0 -1.2 -1.4 11/09/2005 13:00:00 8.1 2.2 13.7 2.6 8.2 2.2 13.7 3.8 6.9 2.3 13.3 1.5 87 19 102 255 -1.4 0 -1.2 -1.4 11/09/2005 13:10:00 8.8 2.3 14.5 3.8 8.8 2.2 14.5 3.8 7.8 2.3 14.5 1.9 88 17 84 255 -1.4 0 -1.2 -1.4 11/09/2005 13:20:00 8.2 2.4 13.3 2.6 8.3 2.3 13.7 3.4 7.2 1.9 11.8 3 89 20 111 255 -1.3 0 -1.2 -1.4 11/09/2005 13:30:00 8.3 2.1 14.9 3.8 8.4 2.1 15.3 4.6 7.2 2.3 13.7 3 84 19 94 255 -1.4 0 -1.2 -1.4 11/09/2005 13:40:00 9.2 2.5 17.2 3.4 9.3 2.5 16.8 3.8 7.9 2.6 16.8 0.7 92 20 94 255 -1.3 0 -1.2 -1.4 11/09/2005 13:50:00 9.9 2.7 19.1 3.8 9.9 2.6 19.1 3 8.3 2.5 14.5 3 94 17 83 255 -1.3 0 -1.2 -1.4 11/09/2005 14:00:00 8.2 2.6 16.1 2.6 8.3 2.5 16.8 3 7.3 2.5 15.3 2.3 90 22 87 255 -1.2 0 -1 -1.2 11/09/2005 14:10:00 9.2 2.6 15.6 3 9.3 2.5 15.6 4.2 7.9 2.8 14.5 1.1 95 19 96 255 -1.3 0 -1.2 -1.4 11/09/2005 14:20:00 8.6 2.1 13.3 3.8 8.6 2.1 13.3 4.2 7.4 1.9 13 3 89 19 75 255 -1.4 0 -1.2 -1.4 11/09/2005 14:30:00 8 2.2 14.5 3.8 8.1 2.2 14.5 3.8 7 2.1 12.2 3 90 18 93 255 -1.5 0 -1.4 -1.4 11/09/2005 14:40:00 7.3 2.1 14.9 2.3 7.4 2 14.5 2.6 6.2 1.8 13 2.3 88 24 124 255 -1.6 0 -1.4 -1.4 11/09/2005 14:50:00 7.9 2.2 13.7 2.6 8 2.2 13 3 6.7 2.2 12.2 1.9 90 20 86 255 -1.6 0 -1.4 -1.4