Port-Clarence_longterm-data
PORT CLARENCE (CGS) AK - 701190 65 deg 15' N 166 deg 52' W - Elev 5m LST=GMT+99 hours *NT=-11 01/73-11/81 01/87-09/90 08/94-06/96 08/00-05/02 Adjusted to Alaska Time Zone (GMT-9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 7.48 8.34 9.85 8.79 7.85 7.02 5.71 5.99 6.33 6.87 7.35 7.86 8.62 1973 7.5 9.06 8.56 8.31 7.46 7.7 4.7 6.1 6.51 6.89 8.15 7.74 8.99 1974 7.61 8.89 9.56 7.47 8.6 6.2 6.06 8.16 6.22 5.75 7.91 6.42 9.67 1975 7.42 8.64 9.64 7.35 7.34 7.27 6.25 6.35 6.62 8.05 7.25 7.34 8.14 1976 7.73 9.7 8.3 10.08 7.39 7.71 5.58 5.9 6.32 7 8.17 8.79 11.04 1977 7.51 9.23 11.58 9.7 7.23 6.52 5.73 5.04 6.19 8.75 7.3 7.83 7.11 1978 7.26 5.53 10.28 8.19 7.5 6.65 6.13 5.68 5.57 6.31 8.83 9.69 9.13 1979 7.82 7.93 6.86 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 1980 7.23 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 7.23 1981 8.06 15.4 -1 -1 -1 -1 -1 -1 -1 -1 7.37 8.21 -1 1987 6.83 10.06 11.59 8.6 7.21 6.07 5.48 4.61 4.49 5.11 7.07 8.47 9.13 1988 7.89 8.62 10.05 10.42 8.17 8.92 5.93 5.78 7.18 6.25 6.43 8.35 8.78 1989 7.7 8.08 11.35 7.57 9.58 7.13 5.58 6.26 7.01 7.55 7.04 7.43 8.28 1990 6.58 7.71 9.55 12.31 7.12 5.01 6.79 7.2 6.95 5.33 -1 -1 -1 1994 6.5 -1 -1 -1 -1 -1 -1 -1 2.8 4.94 7.31 6.75 7.61 1995 5.78 8.82 5.84 4.39 9.33 5.7 3.1 5.84 4.07 3.86 4.78 5.65 6.38 1996 5.42 3.88 4.6 7.61 6.48 2.03 4.05 -1 -1 -1 -1 -1 -1 2000 2.05 -1 -1 -1 -1 -1 -1 -1 2.6 1.5 -1 -1 -1 2002 1.27 2.55 -1 -1 0 0 -1 -1 -1 -1 -1 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 561 816 1172 858 612 427 216 259 302 392 447 605 826 1973 560 1044 820 623 500 554 177 261 288 443 627 557 806 1974 542 677 832 458 687 352 231 640 326 257 590 296 1105 1975 554 1073 1271 525 526 451 317 278 407 527 484 578 702 1976 588 1176 651 1169 497 483 172 256 257 318 508 724 1467 1977 579 954 1814 1085 533 325 192 157 231 729 435 659 506 1978 541 190 1326 774 507 470 260 231 173 313 585 856 931 1979 547 562 408 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 1980 324 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 324 1981 563 2496 -1 -1 -1 -1 -1 -1 -1 -1 396 589 -1 1987 479 1202 1686 868 438 282 184 96 128 186 424 762 972 1988 626 852 1238 1199 670 642 228 222 432 298 269 674 847 1989 615 789 1624 636 1079 442 199 259 382 430 361 487 829 1990 365 464 862 1935 462 161 311 451 351 162 -1 -1 -1 1994 335 -1 -1 -1 -1 -1 -1 -1 23 123 471 341 467 1995 274 1092 187 137 682 203 39 142 60 69 137 178 414 1996 227 144 68 473 251 20 71 -1 -1 -1 -1 -1 -1 2000 6 -1 -1 -1 -1 -1 -1 -1 11 2 -1 -1 -1 2002 8 16 -1 -1 0 0 -1 -1 -1 -1 -1 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 16208 1370 1158 1247 1319 1458 1453 1445 1405 1396 1387 1314 1256 1973 2043 201 163 155 147 138 177 201 166 181 160 171 183 1974 1106 133 94 73 90 108 89 64 77 94 103 91 90 1975 1570 94 61 78 107 119 106 144 168 169 177 155 192 1976 1669 172 169 178 134 161 186 176 168 129 90 62 44 1977 1620 70 89 115 123 146 154 102 140 157 181 180 163 1978 1377 199 174 189 98 114 122 127 113 89 56 51 45 1979 49 44 5 0 0 0 0 0 0 0 0 0 0 1980 7 0 0 0 0 0 0 0 0 0 0 0 7 1981 31 1 0 0 0 0 0 0 0 0 14 16 0 1987 1465 47 25 41 116 135 132 138 138 143 180 185 185 1988 2271 184 182 192 169 196 194 196 178 192 201 188 199 1989 2247 203 181 198 189 202 192 199 184 182 202 184 131 1990 558 8 2 12 119 129 91 93 64 40 0 0 0 1994 61 0 0 0 0 0 0 0 2 14 15 19 11 1995 90 4 10 8 13 5 8 5 6 5 8 12 6 1996 38 8 3 8 13 4 2 0 0 0 0 0 0 2000 2 0 0 0 0 0 0 0 1 1 0 0 0 2002 4 2 0 0 1 1 0 0 0 0 0 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 1026 91 83 86 74 101 87 94 92 90 79 78 71 1 28 1 3 3 2 1 0 1 7 1 4 1 4 2 83 13 6 8 1 4 3 0 3 7 14 12 12 3 1138 120 93 97 94 96 107 88 98 94 99 64 88 4 29 3 2 2 4 1 3 1 1 3 1 8 0 5 99 15 3 12 1 2 2 3 3 9 20 16 13 6 1281 88 83 75 126 131 127 133 129 135 111 72 71 7 1020 60 59 59 101 105 94 94 95 91 92 95 75 8 883 75 64 81 58 84 64 58 56 63 74 104 102 9 1459 135 109 109 134 115 159 140 138 127 102 98 93 10 771 69 58 67 58 68 57 57 50 61 66 84 76 11 578 50 31 29 65 58 66 67 56 59 45 30 22 12 1663 150 125 138 118 146 145 148 144 133 124 145 147 13 343 12 6 13 38 44 49 54 38 40 31 7 11 14 745 68 68 63 47 55 47 51 54 59 67 84 82 15 1283 87 76 82 115 132 142 145 135 112 113 71 73 16 680 58 58 63 55 51 38 44 46 50 59 80 78 17 258 14 4 5 35 32 28 28 26 27 37 12 10 18 1524 138 121 138 92 119 125 128 127 124 131 146 135 19 23 1 3 1 4 0 0 1 1 3 4 3 2 20 66 11 5 4 1 1 3 1 1 8 15 9 7 21 1110 93 88 98 94 106 103 107 101 93 82 76 69 22 31 5 4 5 0 4 1 2 0 0 3 4 3 23 87 13 6 9 2 2 3 0 4 7 14 15 12 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 7.45 8.94 9.63 9.18 7.7 7.09 5.05 5.73 6.08 6.95 7.54 7.33 8.75 1 6.02 4.6 7.83 6.63 6.15 9.2 -1 5.1 4.51 5.1 8.2 3 5.35 2 7.41 6.05 8.08 9.41 4.1 6.62 8.2 -1 6.47 8.7 8.19 6.67 6.88 3 7.39 8.49 8.29 8.38 8.05 6.48 5.67 5.59 6.48 7.02 7.41 8.04 8.91 4 8.19 13.67 7.65 5.35 11.68 0 7.2 3 3.6 10.13 11.3 6.72 -1 5 7.67 6.84 11.3 9.7 0 4.35 7.7 3.4 11.27 8.27 7.05 7.42 8.04 6 6.96 7.79 9.66 8.49 7.08 6.41 5.08 5.75 6 7.35 6.67 7.52 8.47 7 7 8.56 9.82 8.47 7.37 6.52 5.34 5.23 5.83 5.91 6.81 8 8.66 8 7.32 8 10.11 8.67 7.81 6.23 5.51 5.04 5.45 6.07 6.95 8.05 8.4 9 7.3 8.96 9.37 8.57 7.48 6.81 5.45 5.46 6.23 7.1 7.17 7.68 8.82 10 7.37 8.1 11.39 9.03 7.29 6.3 5.07 4.91 5.5 5.86 6.47 8.26 8.97 11 7.32 8.32 9.34 9.12 8.83 7.08 5.37 6.14 6.54 6.97 7.6 7.87 7 12 7.53 7.92 10.64 8.82 7.57 6.87 5.6 5.69 6.11 7.19 7.5 8.05 8.86 13 7.47 10.23 11.03 8.57 9.74 7.31 6.12 6.91 6.67 6.63 7.07 6.14 10.67 14 7.7 7.74 10.6 9.56 7.9 7.56 5.79 5.77 6.54 5.83 6.85 8.05 8.57 15 7.57 8.36 9.36 8.87 8.09 7.26 6.23 6.8 6.71 6.79 8.33 7.45 8.9 16 7.91 8.49 10.5 9.11 7.8 7.73 6.35 6.34 6.62 6.16 6.58 8.42 8.79 17 7.78 7.26 6.62 9.52 9.18 7.62 6.34 7.51 7.32 7.29 7.81 9.36 9.02 18 7.97 8.64 10.34 8.48 8.19 8.39 6.42 6.87 6.79 7.37 8 7.44 8.77 19 7.2 8.2 6.13 12.8 8.7 -1 -1 4.6 10.2 6.8 5.88 7.33 5.35 20 8.12 6.79 10.64 7 8.2 9.2 3.7 10.8 4.6 10.24 7.01 9.62 8.91 21 7.68 8.7 9.37 9.01 7.93 7.51 6.35 6.62 6.75 6.85 8.14 7.76 7.75 22 8.86 13.64 10.25 11.48 -1 7.95 8.2 3.8 -1 -1 5.43 7 5.43 23 7.81 5.48 10.15 6.88 7.65 6.9 5.77 -1 7.8 10.03 6.83 9.81 7.91 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 561 939 1139 1030 521 475 172 224 255 428 485 449 697 1 269 70 408 338 171 507 -1 80 80 83 700 19 211 2 478 215 608 1143 48 319 382 -1 179 703 541 258 459 3 544 825 733 771 547 362 307 254 279 386 462 757 886 4 721 1801 441 111 1645 0 667 16 28 846 888 295 -1 5 648 344 1537 1135 0 78 284 55 1080 596 416 568 1070 6 445 603 985 745 522 324 163 238 241 432 342 531 741 7 492 861 1274 816 481 351 177 169 298 235 365 631 870 8 579 856 1316 858 625 278 172 180 225 311 367 699 783 9 523 951 1029 774 540 373 185 225 282 418 400 530 845 10 594 760 1525 1003 487 323 165 143 215 271 337 709 966 11 516 805 811 1002 863 465 184 273 322 408 491 606 380 12 580 720 1351 872 549 427 191 220 269 458 453 626 909 13 509 1192 1368 823 1085 449 242 341 308 266 379 214 1308 14 627 653 1429 1053 654 510 206 217 358 265 347 644 823 15 544 863 1001 815 657 435 240 346 327 366 671 465 949 16 646 895 1274 905 661 479 266 265 320 272 332 723 871 17 546 616 378 850 881 491 268 422 432 426 459 992 901 18 639 816 1431 748 677 660 260 355 365 484 569 479 856 19 465 382 212 1423 854 -1 -1 58 640 257 253 633 227 20 701 294 1309 332 367 498 64 790 61 1028 338 1619 774 21 596 1033 1146 844 614 503 272 310 402 404 542 602 596 22 1075 2501 1300 2058 -1 598 331 46 -1 -1 193 362 163 23 561 203 1132 466 417 235 362 -1 400 963 315 877 573 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 10.4 10.32 8.96 7.42 6.42 5.86 5.9 5.77 5.54 5.4 5.26 5.28 5.86 7.47 8.29 9.13 9.76 9.86 8.29 6.92 6.46 6.38 6.46 5.61 5.07 4.86 5.07 4.38 4.74 4.69 5.09 4.79 5.94 6.25 7.73 8.93 10.4 1 0 12.1 11.9 10.7 7.7 6.5 6.2 6.1 5.4 5.5 5.8 5.4 6.9 6.8 11 9.1 11.2 10.8 14.4 11.4 10 5.8 9.3 7.9 6.3 6.7 5.9 5.1 2 4.5 4.8 6.7 1.8 8.5 5.1 16 10.7 12.1 2 0 13.8 13.1 11.4 8.9 7.1 6.1 6.4 7.5 4.9 5.5 4.8 6.4 5 7.2 11.6 13.4 15.2 13.5 11.5 8 9.5 6.4 13.9 7.7 7.4 5.6 6.9 4.9 10.8 8.8 -1 5.9 7.4 7.2 8.8 12.1 13.8 3 0 13 11.7 9.9 7.8 6 5.4 5.9 5.6 6.4 6.4 5 8.7 5.4 11.1 8.5 9.3 9.1 10.9 9.2 7.8 6.2 10.8 6.3 10.2 4.8 2.5 8.8 5.8 9.8 2.5 6.4 2.9 9.6 9.3 15.2 12.6 13 4 0 11.2 10.4 9.4 7.9 5.8 5.1 5.1 4.9 4.9 5 4.8 4.2 9.2 7 8 10.2 10.9 11.3 8.2 6.4 7.2 5.5 5.1 4.8 4.8 3.7 6.6 3.9 3.5 4.5 7.2 2.7 6.8 7.5 7.1 10.5 11.2 5 0 9.8 9.7 8.7 6.4 5.5 4.9 3.6 4.6 4.2 3.9 4.6 3 5.6 5.9 5.4 6.6 7.8 6.9 6 5 4.1 3.6 4 3.1 2.4 4.8 4.3 4 4 3.9 4.3 4.2 4.3 4.6 6.6 9.1 9.8 6 0 8.7 8.6 7.3 5.3 4.7 4.4 5 4 3.1 3.4 4 2.5 4.5 4.3 3.7 6.2 6.1 6.4 5.8 5.7 5.3 4.9 5.1 4.5 4.7 4.2 4.5 4 4.4 4.7 4.3 4.1 4.7 3.8 5.6 6.8 8.7 7 0 8 7.1 6.2 5.1 5 4.2 3.8 4.2 4.9 3.5 4.5 4.1 3.6 3.9 5.7 6.5 8 8 8.5 6.6 7.1 6 6 5.4 4.8 4 4.7 4.1 4.8 4.2 4.2 4 4.8 5 7.1 6.8 8 8 0 8 7.9 6.8 5.3 4.5 4.8 4.7 5.3 4 4.3 4.9 4.6 4.1 5.6 6.5 6.8 8.1 8.4 9.5 7.5 7 6.7 6.7 5.5 4.7 5.2 4.1 4.6 3.8 4.9 4.6 4.3 3.6 4.8 7.2 5.9 8 9 0 9 8.3 6.8 6.2 5.9 5.5 6.2 5.7 5.2 5.2 5.2 5.6 4.9 8.3 8.3 6.9 9.2 9 8.1 8.8 7.1 7.7 7.9 7.3 5 5.5 5.5 4.2 4.1 5.2 4.8 4.8 5.3 6.5 6.6 8.3 9 10 0 8.5 7.5 7.1 7.2 7.4 7.7 7 6.3 5.6 6.2 7 5.9 5.3 7.2 8.5 10.2 10.5 7.2 7.7 8.7 6.8 5.9 6.5 8.1 7.1 6.9 8.1 6.5 7.9 6.6 7.4 7.5 7.6 6 7.5 8.2 8.5 11 0 11.4 11.1 9 7.7 8 6.6 6.4 5.9 6.1 5.6 4.6 7.6 6.6 8.5 10.4 10.4 9.1 10.5 8.2 7.7 7.2 7.6 9.4 -1 10.9 8.3 6.6 6.7 6.3 10.3 9.7 8.6 7.3 7.3 10.4 11.2 11.4 12 0 13.7 12.4 9.9 9.4 6.5 5.8 5.9 6.6 7.2 6.2 6.5 5 8 10.2 9.9 10.9 10.9 9.2 9.2 8.6 6.7 12.8 6.1 8.9 4.9 5.6 3.7 6 6.9 4.8 6.4 2.5 7.2 8.4 8.3 10.5 13.7 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0.4 6.26 10.77 9.89 6.99 6.59 5.7 6 5.02 2.5 1.9 1.09 0.83 0.94 0.96 1.44 1.76 2.33 2.56 3.64 2.58 2.15 1.6 1.47 1.39 1.31 1.09 0.79 0.98 0.97 1.36 1.24 0.76 0.88 0.95 1.3 1.97 6.26 1 0.5 4.2 8 11.3 7.8 10.9 10 10.2 6.6 3.4 2.9 0.7 0.7 1.8 0.9 1.5 2.3 2.9 3 3.1 1.6 0.6 0.6 0.7 0.4 0.4 0.3 0.1 0.1 0.3 0.2 0.1 0.1 0.2 0.7 0.1 1 4.2 2 0.4 5.6 14.8 13.6 9.8 8.3 8.4 6.8 4.2 2.1 1.8 1 1 1 0.6 1.4 1.9 3.2 5.3 2.3 1.1 0.5 0.3 0.1 0.8 0.3 0.2 0.2 0.2 0.1 0.1 0 0.3 0.2 0.8 0.7 1.1 5.6 3 0.2 7.8 19 13.4 11.7 9.3 8.3 7.6 4.5 1.6 0.8 0.6 0.1 0.4 0.6 0.5 1 1 2.3 1.7 0.5 0.6 0.9 0.6 0.3 0.2 0.2 0.1 0.2 0.2 0.2 0.5 0.3 0.4 0.5 0.5 1.6 7.8 4 0.8 6.2 16 15.4 6.9 7.9 7.9 4.7 4.8 2.5 1.8 1.4 0.6 1.1 1.4 1.6 2.3 2 2.4 2.4 1.3 1 1 0.7 0.8 0.6 0.5 0.4 0.2 0.3 0.4 0.5 0.2 0.5 0.6 0.6 0.8 6.2 5 0.4 10.3 20.2 12.5 4.7 4.5 2.8 3.2 2.8 1.9 1 1 0.8 1.3 1.1 1.4 1.6 1.9 2.4 3 1.9 1.4 0.6 0.4 1 0.6 1 0.8 1.9 1.4 1.6 1.8 1.1 1 0.9 1.3 2.9 10.3 6 0.2 6.8 8.2 6.1 4.4 2.5 1.9 2 1.4 0.7 0.8 0.8 0.7 0.4 0.8 0.5 1.5 2.1 3 7.6 7.6 5.2 3 2.5 2.5 3 1.8 2.1 2 2.9 4.4 2.7 1.5 1.3 0.8 2 2.2 6.8 7 0.4 4.6 5.3 4 2.6 2.5 1.9 2.1 2 1.2 0.9 0.5 1 0.6 0.6 1 1.2 3.4 3.5 8.8 5.8 6.7 5.3 3.8 3.5 3.5 3.5 2 2.6 2.8 3.7 2.2 1.5 0.8 0.6 1.1 2.8 4.6 8 0.9 4.9 5.9 8.3 5.2 3.2 2.5 3.1 3.4 1.2 1.5 1.4 1 0.9 0.8 1.4 1.7 1.7 3 6.7 6 5.1 4.5 4.6 4.4 2.6 1.7 1.3 1.9 0.9 2.5 2.1 0.8 0.9 0.6 1.4 1.1 4.9 9 0.4 7.8 9.2 9 6.1 4.7 3.8 4.8 4.4 2.3 1.7 0.9 1 1.4 1.5 2 2.2 2.6 2.7 2.6 1.9 2.2 1.4 2.4 1.3 1.7 1.5 0.7 1.1 1.1 1.5 2.2 1.3 1.8 1.9 1.9 3.5 7.8 10 0.2 6.9 6.4 6.4 8.3 8.4 6.6 9.1 8.8 4.2 3.5 1.5 0.6 0.8 1.3 2.2 2.3 2.3 1 1.7 0.9 0.9 0.3 0.4 0.6 1.1 0.5 0.7 0.4 0.4 0.6 1.2 0.8 1.9 1.6 2.6 2.7 6.9 11 0.2 4.9 5.7 8.4 8.1 9.8 8.5 10.4 10.8 5 3.6 1.8 1.7 1.1 0.8 2.2 1.6 1.9 0.9 1.1 0.8 0.2 0.5 0.4 0 0.4 0.7 0.5 0.4 0.2 0.1 0.5 0.7 0.9 1.8 2 2 4.9 12 0.2 4.9 12 12 10 8.4 7.5 9.3 7.4 4.3 2.7 1.8 0.9 0.5 1 1.5 1.6 2.9 1.3 1.5 0.6 0.4 0.1 0.2 0.2 0.7 0.6 0.3 0.2 0.4 0.2 0.4 0.1 0.5 0.6 1.3 1.6 4.9 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0.4 2.1 6.8 7.6 11 16.5 8.8 10.2 4.6 5.3 8.6 3.7 5 1.4 1.5 2.8 0.7 0.5 1.3 0.3 0.5 0.1 0.1 0.1 0 0 1 0.5 2.1 3.6 4.6 10.6 18.7 8.8 10.7 3.4 3.7 8.3 3.2 6 1.2 1.5 5.5 1.2 0.8 2.6 0.9 1.3 0.2 0.1 0.3 0 0 2 0.4 0.9 3 4.4 7.3 13.2 6.8 7.7 3.5 3.4 10.3 5 8.3 2.7 3.1 8.3 2 1.7 4 1 1.4 0.4 0.3 0.2 0.1 0.3 3 0.2 1.3 4.1 5.8 8.3 14.4 7.5 8.8 4 5.3 11.2 4.9 7.4 2.3 3 4.8 1.4 1 2.8 0.5 0.6 0.1 0.1 0.3 0 0 4 0.8 1.4 6.3 6.1 11.3 16.1 8.4 8.6 3.6 6.1 9.1 4.3 6.6 2.3 2.5 3.4 0.8 0.5 1.1 0.5 0.2 0.1 0.1 0 0 0 5 0.4 3.4 10.9 8 10.4 12.6 7.4 9.7 4.8 6.1 8.9 6 6.4 1.6 1.8 1 0.1 0.3 0.2 0 0.1 0 0 0 0 0 6 0.2 3.1 11.6 11.8 17.1 17 9.8 9.3 4.9 4.9 5.8 2.1 1.2 0.6 0.4 0.1 0 0 0 0 0 0 0 0 0 0.1 7 0.4 2.9 10.1 12.9 13.4 18.8 9.1 8.8 5 5.5 6.4 2.4 1.8 0.6 0.6 0.8 0.1 0.1 0.1 0 0.1 0 0 0 0 0 8 0.9 2.9 9 9.6 14.2 16.8 9.5 9.6 6.4 5.3 6.4 3.1 2.8 1.4 0.6 0.7 0.1 0.1 0.1 0.1 0.1 0 0 0.1 0 0 9 0.4 3.6 7.8 8.1 10.6 16.5 10.6 11.7 4.4 5.9 7.7 2.9 3.8 1.1 0.9 2.4 0.4 0.1 0.7 0.1 0.1 0 0 0 0 0 10 0.2 1.2 5.4 6.3 10 17.7 10.3 14.6 4.5 5.9 9.8 3.7 4.8 0.8 0.8 1.9 0.6 0.1 0.6 0.1 0.2 0 0.1 0.1 0 0 11 0.2 0.8 3.9 6.2 9.3 19.3 8.9 13.5 5.8 5.5 7.8 3 5 1.3 2 3.2 1.1 0.6 2 0.1 0.5 0 0 0.2 0 0.1 12 0.2 1 3.7 5.4 8.4 16.5 8.4 9.2 4.2 5.4 12.7 3.8 7.1 1.7 1.5 3.6 0.8 0.6 2.6 0.6 1.8 0.3 0.1 0.2 0 0.1 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0 0.1 0.3 1 2.8 2.6 5.1 3.2 5.1 11.1 6.6 12.1 4.3 5.5 12.3 3.7 2.8 9.3 2.6 5 1 0.8 1.6 0.1 0.9 1 0 0 0 0.2 0.7 2.3 1.8 3.9 1.8 2.6 7.5 4.1 10.2 2.7 3.8 16.6 4.8 3.5 13 5.3 9.4 1.7 1.3 2.8 0 0 2 0 0 0 0.1 0.4 1.1 1 1.9 1.2 1.6 6.6 4.5 10 3.9 5.5 17.6 5.1 5 13.5 4.3 6.8 2.4 2.2 1.3 0.7 3.3 3 0 0 0 0.2 0.5 1.7 1.5 3 1.9 3.6 9.9 6 12.3 4.7 7.6 14 5 4.2 13.2 2.7 3.7 0.6 0.6 3.2 0 0 4 0 0 0.1 0.3 1 2.6 2.3 4.1 2.5 5.5 11.1 7.3 14.9 6.3 8.4 13.6 4 2.5 7.2 3.6 1.4 0.7 0.8 0 0 0 5 0 0 0.2 0.5 1.3 2.8 2.8 6.3 4.5 7.7 15.1 13.7 19.8 6.1 8.1 5.3 0.9 2.2 1.8 0 0.9 0 0 0 0 0 6 0 0 0.4 1.3 4.2 7.4 7.3 11.4 8.7 11.7 19.2 9.2 7.3 4.1 3.7 0.7 0 0 0 0 0 0 0 0 0 3.4 7 0 0 0.3 1.1 2.6 6.5 5.5 9 7.2 10.9 17.2 9 8.8 3.8 4.2 6.6 1.6 0.8 1.9 0 2.9 0 0 0 0 0 8 0 0 0.3 0.7 2.4 5 4.9 8.4 8 9.3 14.4 9.7 12.1 7.4 3.9 5.3 1.3 0.7 0.9 1 2.4 0 0 1.8 0 0 9 0 0 0.2 0.5 1.4 3.9 4.3 8 4.3 7.9 13.7 7.2 12.5 4.3 4.5 14.3 2.7 1.2 6.6 1.6 1 0 0 0 0 0 10 0 0 0.1 0.3 1.2 3.7 3.9 9.1 3.9 7 15.3 8.1 14 2.9 3.4 9.6 3.8 0.5 5.3 1.5 2.7 0 1.1 2.6 0 0 11 0 0 0.1 0.3 0.8 3 2.5 6.4 3.9 4.9 9.3 5 11.2 3.6 6.6 12.6 5.1 3.5 12.7 0.6 4.3 0 0 2.1 0 1.4 12 0 0 0 0.2 0.6 2 1.8 3.3 2.1 3.7 11.6 4.7 12.1 3.5 3.8 10.6 2.8 2.7 12.4 3.2 12.3 2.5 0.7 2.4 0 1 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 20 -1 -1 20 -1 -1 20 10 10 20 10 10 10 10 10 10 10 10 10 -1 -1 20 -1 -1 1 20 -1 -1 20 -1 50 10 40 50 20 50 30 20 -1 50 20 40 -1 20 -1 -1 20 -1 -1 2 10 -1 -1 20 -1 -1 30 50 10 20 10 30 20 -1 10 20 10 -1 10 -1 -1 10 -1 -1 3 20 -1 -1 30 -1 -1 10 10 10 10 10 10 10 -1 10 20 10 -1 10 -1 -1 30 -1 -1 4 20 -1 -1 10 -1 -1 20 10 10 50 10 20 10 10 10 20 10 10 20 -1 -1 20 -1 -1 5 10 -1 -1 10 -1 -1 10 10 10 10 10 10 10 10 10 10 10 10 10 -1 -1 20 -1 -1 6 360 -1 -1 20 -1 -1 20 30 30 30 50 200 180 360 190 190 360 190 10 -1 -1 360 -1 -1 7 180 -1 -1 20 -1 -1 30 20 190 180 60 180 200 180 210 190 190 180 220 -1 -1 360 -1 -1 8 20 -1 -1 20 -1 -1 30 20 20 20 20 180 10 170 180 360 190 180 200 -1 -1 10 -1 -1 9 20 -1 -1 20 -1 -1 360 10 10 20 10 10 360 30 360 360 10 10 10 -1 -1 20 -1 -1 10 40 -1 360 360 -1 360 20 60 50 30 60 50 70 40 60 70 60 50 40 -1 30 40 -1 10 11 60 -1 -1 70 -1 70 40 40 30 60 20 70 40 -1 40 70 70 -1 60 -1 -1 60 -1 10 12 30 -1 -1 20 -1 -1 10 20 10 30 40 60 10 -1 10 30 20 -1 20 -1 -1 20 -1 -1 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 8.87 -1 -1 8.58 -1 -1 8.37 9.97 10.46 8.79 10.82 9.9 10.73 9.68 11.83 10.33 10.71 9.65 11.23 -1 -1 9.49 -1 -1 1 10.16 -1 -1 9.79 -1 7.98 9.38 5.72 5.71 11.59 6.16 8.05 9.47 -1 5.24 12.09 5.95 -1 11.04 -1 -1 12.58 -1 -1 2 13.7 -1 -1 10.09 -1 -1 9.21 5.23 13.37 11.19 13.26 8.52 12.66 -1 14.13 12.6 12.95 -1 12.27 -1 -1 12.78 -1 -1 3 9.38 -1 -1 6.92 -1 -1 9.9 12.78 12.42 12.18 14.81 10.24 11.87 -1 13.24 10.74 11.19 -1 11.72 -1 -1 8.11 -1 -1 4 10.19 -1 -1 9.72 -1 -1 7.42 10.03 11.19 5.02 9.89 9.61 9.78 10.36 10.32 9.92 10.17 11.17 10.11 -1 -1 9.72 -1 -1 5 8.71 -1 -1 8.87 -1 -1 8.6 10.19 8.99 9.4 9.82 11.46 10.13 9.72 10.44 9.61 9.52 8.75 10.93 -1 -1 10.17 -1 -1 6 7.9 -1 -1 7.07 -1 -1 6.92 5.34 5.44 4.93 2.46 3.94 5.39 7.83 5.56 5.48 9.7 5.14 10.27 -1 -1 9.84 -1 -1 7 8.02 -1 -1 5.78 -1 -1 4.89 5.96 5.14 7.77 4.62 9.12 5.8 7.47 8.37 6.92 4.9 8.8 7.35 -1 -1 7.35 -1 -1 8 7.04 -1 -1 6.1 -1 -1 5.41 7.15 4.95 6.91 7.4 11.38 9.26 9.77 7.3 8.52 7.45 10.83 8 -1 -1 10.03 -1 -1 9 7.7 -1 -1 6.68 -1 -1 8.47 7.27 8.54 7.12 8.23 9.04 9.28 8.04 7.54 9.6 7.4 7.03 10.18 -1 -1 6.71 -1 -1 10 8.08 -1 9.07 8.15 -1 6.47 7.52 5.98 6.47 7.45 5.95 9.77 5.85 7.2 6.33 6.23 6.26 9.88 7.55 -1 7.4 8.21 -1 4.1 11 6.55 -1 -1 6.3 -1 5.43 8.13 8.11 7.75 6.27 9.51 5.88 8.76 -1 8.28 4.98 5.77 -1 6.94 -1 -1 7.17 -1 13.6 12 10.92 -1 -1 10.15 -1 -1 10.96 10.03 11.42 9.13 6.56 5.92 12.79 -1 13.67 9.27 11.04 -1 9.91 -1 -1 8.77 -1 -1