Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Sand-Point_longterm-data
SAND POINT AK - 703165 55 deg 19' N 160 deg 31' W - Elev 7m LST=GMT+99 hours *NT=-11 01/73-04/74 05/80-09/83 06/87-09/02 Adjusted to Alaska Timezone (GMT=9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 4.97 5.84 5.38 5.23 5.08 4.3 3.79 3.61 4.1 4.88 5.95 6.34 6.15 1973 4.26 4.77 2.72 3.48 6.38 3.05 -1 0 0 5.43 7.2 -1 5.75 1974 7.33 4.6 5.1 4.1 12.8 -1 -1 -1 -1 -1 -1 -1 -1 1980 4.73 -1 -1 -1 -1 3.78 5.13 3.91 -1 4.6 -1 -1 6.4 1981 4.83 5.9 8.2 2.5 -1 -1 5.01 4.57 5.1 3.6 -1 -1 -1 1982 4.74 11.3 -1 -1 -1 3 -1 5.1 3.64 -1 -1 -1 -1 1983 4.05 -1 -1 -1 -1 -1 -1 -1 3 5.1 -1 -1 -1 1987 5.55 -1 -1 -1 -1 -1 5.15 4.15 4.62 6.27 5.87 6.35 6.51 1988 5.11 4.18 6.47 5.72 5.51 4.55 4.22 3.2 4.13 5.21 5.45 5.48 7.72 1989 4.88 6.43 5.39 5.2 4.94 4.38 3.68 3.68 3.83 4.81 5.41 5.86 5.62 1990 4.43 5.67 5.34 5.45 4.25 3.8 3.27 3.13 3.78 3.99 4.88 5.73 4.38 1991 5.02 5.9 6.69 5.75 4.28 4.69 3.74 3.44 3.96 4.63 5.14 6.78 5.8 1992 5.38 6.54 5.16 5.59 6.05 4.59 4.85 4.04 5.3 4.64 6.15 5.9 5.84 1993 4.9 7.42 5.42 5.11 5.09 4.21 3.75 4.18 3.54 4.28 4.51 6.61 4.92 1994 5.2 4.59 5.88 6.77 5.24 3.83 3.64 3.23 4.09 5.21 6.37 8.36 6.58 1995 4.69 4.81 4.84 5.72 5.38 4.03 3.74 3.77 4.09 3.86 6.12 5.35 4.19 1996 5.24 5.46 6.97 3.69 4.74 4.2 5.19 3.63 4.38 5.34 5.8 6.36 7.08 1997 4.81 5.75 4.59 5.92 4.09 3.99 3.47 3.37 4.38 5.23 5.8 5.94 6.94 1998 5.11 5.04 4.34 4.52 6.49 5.5 4.2 3.34 4.81 5.3 5.85 5.47 6.73 1999 5.08 6.19 6.03 4.9 5.62 4.11 3.11 3.88 4.17 4.48 5.75 6.99 6.39 2000 5.12 7.46 4.56 5.08 4.08 4.43 3.85 3.82 4.52 4.52 6.38 6.54 6.16 2001 5.59 5.43 4.86 6.79 5.41 5.46 4.05 4.54 4.49 6.12 6.9 6.15 6.64 2002 3.86 6.29 5.89 4.2 4.9 3.65 2.67 3.08 2.92 4.64 -1 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 203 334 248 235 191 109 78 67 103 162 295 375 346 1973 158 67 21 59 440 68 -1 0 0 201 224 -1 273 1974 477 114 80 41 1257 -1 -1 -1 -1 -1 -1 -1 -1 1980 116 -1 -1 -1 -1 54 144 49 -1 61 -1 -1 193 1981 97 247 341 10 -1 -1 96 88 82 28 -1 -1 -1 1982 149 888 -1 -1 -1 17 -1 161 49 -1 -1 -1 -1 1983 49 -1 -1 -1 -1 -1 -1 -1 16 82 -1 -1 -1 1987 221 -1 -1 -1 -1 -1 130 87 116 233 257 357 371 1988 187 117 322 212 190 102 75 45 73 192 211 210 543 1989 150 372 201 233 139 82 58 51 56 124 152 206 182 1990 116 172 190 212 92 57 50 36 63 63 119 255 131 1991 175 226 311 231 84 106 62 48 85 151 170 402 279 1992 200 341 178 193 259 108 108 74 166 157 236 272 369 1993 172 432 205 167 156 89 80 77 50 110 148 408 172 1994 235 120 341 402 181 74 69 55 94 213 330 630 429 1995 180 208 187 327 183 69 72 79 100 89 387 246 126 1996 251 371 460 131 148 103 177 77 118 212 266 445 507 1997 205 250 179 353 146 106 65 65 130 180 257 403 564 1998 213 216 135 204 334 217 109 53 141 199 304 268 408 1999 224 539 343 198 250 124 46 76 104 114 222 417 334 2000 240 553 218 208 120 116 77 71 145 152 478 387 358 2001 249 310 213 339 248 182 64 125 144 191 373 362 324 2002 108 393 240 116 170 58 30 46 45 67 -1 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 90733 7262 6758 7189 7200 8403 8854 8680 8759 6728 7318 7054 6528 1973 39 3 5 6 4 2 0 3 1 6 1 0 8 1974 6 2 1 1 2 0 0 0 0 0 0 0 0 1980 230 0 0 0 0 61 156 10 0 1 0 0 2 1981 152 5 1 1 0 0 71 72 1 1 0 0 0 1982 17 1 0 0 0 1 0 8 7 0 0 0 0 1983 2 0 0 0 0 0 0 0 1 1 0 0 0 1987 1696 0 0 0 0 0 216 259 240 252 268 229 232 1988 2911 252 239 221 265 263 256 251 240 220 239 242 223 1989 2770 226 203 249 233 235 251 258 255 228 244 184 204 1990 2841 235 188 203 204 254 247 244 274 238 260 233 261 1991 3094 253 237 258 254 231 266 247 329 263 273 239 244 1992 3012 257 236 252 244 256 328 285 249 174 297 213 221 1993 3183 355 216 217 220 459 379 234 226 229 238 207 203 1994 6467 194 199 290 283 688 692 732 736 702 734 696 521 1995 7652 659 652 664 620 166 704 698 665 695 734 684 711 1996 8379 712 692 730 634 737 705 643 715 705 724 715 667 1997 7761 687 626 681 704 733 697 748 734 649 503 689 310 1998 8284 685 648 707 680 704 695 734 704 705 684 710 628 1999 8255 652 565 562 692 796 743 761 692 716 691 711 674 2000 8625 719 680 728 707 723 713 727 736 721 721 714 736 2001 7415 735 686 706 711 670 463 617 641 208 707 588 683 2002 7942 630 684 713 743 1424 1272 1149 1313 14 0 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 2950 221 190 211 218 315 316 310 324 217 215 214 199 1 3002 226 235 247 238 306 304 292 304 198 219 231 202 2 3028 247 211 228 240 319 303 293 317 212 221 238 199 3 2820 214 187 207 215 304 291 287 296 186 217 220 196 4 2906 220 234 240 224 294 296 272 290 197 214 225 200 5 2976 220 211 228 233 305 289 301 307 222 235 223 202 6 3027 237 200 205 225 330 331 314 313 207 235 225 205 7 4117 241 233 250 399 437 474 455 459 355 397 220 197 8 5171 408 380 392 449 452 489 498 468 425 434 397 379 9 4840 384 386 397 379 391 451 451 433 386 428 386 368 10 4875 408 393 417 393 394 450 432 435 379 405 381 388 11 4867 390 379 404 394 403 441 465 429 371 427 382 382 12 5032 406 378 401 410 434 494 471 456 406 420 386 370 13 4900 409 387 421 385 398 452 464 418 383 413 398 372 14 4931 428 369 394 409 419 444 450 443 385 416 404 370 15 4686 382 352 371 366 381 459 433 433 361 408 383 357 16 4568 396 366 399 354 363 406 407 398 338 371 394 376 17 3714 363 348 353 283 280 284 305 333 228 280 337 320 18 3216 244 215 240 241 310 348 325 360 234 233 247 219 19 3084 248 238 262 228 308 327 285 327 201 234 227 199 20 3200 257 215 228 248 331 322 333 333 246 244 234 209 21 2898 229 210 231 210 312 293 278 290 196 212 232 205 22 2997 244 223 236 232 308 296 289 305 206 213 236 209 23 2928 240 218 227 227 309 294 270 288 189 227 234 205 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 4.51 5.97 5.08 4.78 4.41 3.83 2.89 3.02 3.67 4.24 6 6.37 6.17 1 4.5 5.7 5.25 4.93 4.4 3.7 2.77 2.96 3.56 4.09 6.02 6.31 6.08 2 4.45 5.62 5.14 4.89 4.37 3.58 2.79 2.92 3.51 4.26 5.86 6.32 5.91 3 4.48 5.92 5.14 4.74 4.48 3.81 2.83 2.79 3.46 4.26 5.98 6.13 6.26 4 4.55 5.93 5.22 4.89 4.64 3.72 2.79 2.92 3.35 4.24 6.09 6.13 6.34 5 4.5 5.58 5.2 4.75 4.54 3.48 2.76 2.88 3.69 4.44 6.03 6.32 6.15 6 4.46 5.69 5.02 4.75 4.57 3.66 2.95 3.01 3.46 4.28 5.96 6 6.28 7 4.35 5.83 5.24 4.63 4.62 3.5 3.27 2.86 3.45 4.28 5.41 6.27 6.44 8 4.68 5.78 5.45 4.88 4.68 3.9 3.42 3.27 3.64 4.39 5.63 6.15 5.92 9 4.81 5.89 5.23 4.96 4.91 4.26 3.71 3.55 3.88 4.44 5.25 5.96 6.2 10 4.98 5.65 5.21 5.3 4.92 4.61 3.97 3.67 4.17 4.79 5.51 6.14 6.19 11 5.16 5.79 5.36 5.26 5.29 4.7 4.31 3.8 4.4 5.15 5.79 6.17 6.29 12 5.33 5.86 5.55 5.74 5.49 4.92 4.52 4.19 4.59 5.29 6.02 6.16 6.22 13 5.5 5.88 5.63 5.59 5.73 5.1 4.54 4.43 4.99 5.52 6.25 6.32 6.41 14 5.56 6.04 5.83 5.86 5.77 5 4.8 4.33 4.75 5.69 6.34 6.6 6.01 15 5.58 6.22 5.77 5.66 5.8 5.13 4.79 4.43 4.87 5.57 6.3 6.69 6.1 16 5.6 6.12 5.71 5.83 5.77 5.16 4.84 4.23 4.89 5.63 6.17 6.83 6.15 17 5.61 5.98 5.78 5.92 5.82 5.06 4.69 4.34 4.82 5.61 6.49 6.41 6.21 18 5.28 5.88 5.14 5.67 5.65 4.74 4.45 4.15 4.5 5.56 6.28 6.64 6 19 5.1 5.67 5.24 5.16 5.61 4.64 4.16 4.03 4.37 5.15 5.94 6.45 6.04 20 4.93 5.79 5.16 5.23 5 4.34 3.82 3.73 4.05 4.91 6.08 6.59 6.08 21 4.82 5.85 5.08 4.94 4.89 4.12 3.53 3.6 3.89 4.85 6 6.42 6.06 22 4.61 5.38 5.25 4.61 4.61 3.87 3.3 3.22 3.75 4.46 5.83 6.31 6.19 23 4.58 5.66 5.26 4.73 4.43 3.74 3.05 2.97 3.68 4.5 6.04 6.29 5.91 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 188 364 243 226 169 97 53 58 92 139 340 372 336 1 188 348 253 220 153 88 54 57 101 113 316 383 317 2 186 361 236 234 149 89 50 52 85 134 306 373 321 3 187 382 218 216 162 88 53 50 82 126 331 344 378 4 194 387 252 235 176 91 52 53 71 130 334 350 354 5 189 303 260 221 176 81 52 53 96 151 321 382 351 6 191 357 241 212 177 90 56 55 87 148 340 361 380 7 174 376 267 199 177 74 65 50 77 129 278 412 377 8 192 338 263 217 173 95 61 62 83 141 264 369 343 9 191 336 258 218 173 101 73 65 91 138 215 336 351 10 200 300 241 248 173 115 78 65 95 148 257 376 340 11 209 304 233 232 204 110 92 69 115 170 264 345 424 12 215 367 253 269 204 127 97 79 118 168 284 328 369 13 219 305 246 225 224 138 96 87 143 177 309 333 397 14 221 312 248 259 220 130 112 81 119 199 304 404 305 15 217 313 240 230 225 135 109 86 138 185 284 394 312 16 230 327 258 265 213 139 111 80 127 207 287 423 334 17 238 331 250 277 238 138 106 87 120 207 337 375 336 18 211 335 240 266 227 126 97 82 111 200 301 431 293 19 205 315 248 243 212 129 84 75 105 174 305 393 331 20 207 350 257 244 175 116 75 72 107 183 323 431 335 21 198 357 229 222 188 115 63 67 87 177 319 384 313 22 187 297 249 206 170 94 65 56 99 140 302 375 332 23 189 326 245 205 158 89 58 47 96 151 317 373 326 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 7 5.16 4.31 4.16 4.25 3.67 3.37 2.98 2.84 2.67 2.98 3.46 4.01 4.29 4.25 4.53 5.33 5.66 6.4 6.62 6.9 6.24 5.76 5.46 5.43 4.93 4.64 4.88 4.95 4.86 5.32 5.71 6.06 6.68 7.68 7.66 7 1 0 8.3 6.5 5.4 5 4.7 3.8 3.7 2.8 3 3 3.5 4.3 3.5 3.8 4.1 5.3 5.9 7.7 8.3 8.5 8.9 7.9 7.4 6.1 4.9 4.8 4.6 4.7 5 5 5.9 7 7 7.3 8.8 9 8.3 2 0 8.1 5.8 4.9 4.5 4.9 4 3.8 3.2 3 2.7 3 3.7 4.4 4.1 4 4.9 6.3 7.6 7.8 7.2 6.6 6.8 5.9 5.8 6 5 4.7 5.4 6.4 5.3 6.3 6 6.2 7 8 7.6 8.1 3 0 7.5 5.9 4.7 4.3 4.5 3.8 3.2 3 2.8 2.5 2.7 3.2 3.4 4 4 4.4 5.4 5.9 7 7.8 7.5 6.2 5.9 5 6.1 6.2 5.6 5.5 5.4 5 5.8 6.7 7.1 7.2 8.3 8.3 7.5 4 0 6.6 5 4.1 4.1 3.9 3.6 3.5 2.9 2.3 2.5 2.5 3.4 4.1 4.8 4.6 4.5 5.7 6 7.2 6.9 6.9 6.3 6.4 6.4 6 5.3 4.9 5.1 5.6 5.1 5.6 6.4 6.4 6.4 6.8 7 6.6 5 0 6.1 4.5 4.2 4 4 3.7 3.3 2.9 2.8 2.9 3.2 3.6 3.7 4.1 3.7 3.9 4.9 5.1 5.5 5.7 5.6 5.6 4.8 4.1 4.7 4 3.8 4.1 4.5 4.1 4.1 4.6 5.1 5.8 6 6.5 6.1 6 0 5.7 4.3 3.7 3.8 3.9 3.6 3.2 3.2 3 2.7 3 3.7 4.2 4.1 4 3.6 4.6 4.4 4.8 5.4 5.7 4.6 4.2 4.1 4 4.1 4.3 4.6 3.7 4 4 4.2 4.9 4.7 4.9 5.3 5.7 7 0 4.8 3.9 3.3 3.1 3.5 3.2 2.9 2.8 3 2.5 2.5 3 4.1 4 3.9 3.4 4.6 4.3 5.1 5 5.1 4.7 4.6 3.9 3.5 3.4 3.3 3.5 3.7 3.8 3.7 4.2 4.6 4.3 5 4.9 4.8 8 0 5.4 4.5 3.6 3.1 3.1 3 3.1 2.8 2.8 2.7 2.9 3.4 4.1 4.5 4.5 4.2 4.7 4.7 5.4 5.9 5.9 4.8 4.7 4.4 4.3 3.9 3.9 3.8 3.9 3.9 4.1 4.5 5 5.2 6.1 6 5.4 9 0 6.2 4.7 4.2 4.1 4.2 4 3.1 2.8 2.4 2.5 3.1 3.9 3.7 4.2 4.8 4.5 5 6 6.3 7 7.6 6.2 5.3 5 4.9 4.4 4.2 4.4 4.6 4.8 5.1 5.6 5.9 6.3 6.8 7.1 6.2 10 0 7.7 6.3 5 5.4 5.1 4 3.7 3 2.7 2.5 3.1 3.2 5.2 4.8 4.6 5.1 6.1 7.1 7.5 6.8 7 6.4 5.5 5.4 5.5 5 4.6 4.8 5 5 5.7 6.1 6.4 7.7 8.9 8.8 7.7 11 0 8.3 6.5 5.4 5.2 4.6 3.6 3.2 2.6 2.7 2.4 2.5 2.6 3.3 3.6 3.9 5.2 6.6 8.2 7.3 7.9 8.6 7.9 7 6.6 6.3 5.7 5.5 6.2 6.1 6.1 6.8 6.8 6.8 8.2 9.4 10 8.3 12 0 8.2 6.6 5.6 5.2 4.7 3.9 3.8 3.6 3.3 2.8 3.5 3.5 4.7 5.4 5.5 6 7 8.9 7.9 7.8 8.2 6.9 7.3 7.2 6.8 6.2 5.6 5.8 5.5 5.7 6 6.5 7.3 8.4 9.4 8.9 8.2 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 9.21 5.82 3.08 2.15 2.72 3.78 3.36 2.44 1.7 1.25 1 0.8 0.98 1.19 1.89 2.22 3.93 6.87 4.66 3.37 3.01 2.47 1.52 1.21 1.25 1.27 1.15 1.31 1.56 2.03 2.29 3.41 4.07 4.5 4.91 5.15 5.7 5.82 1 9.4 8.2 2.8 2.3 2.7 5 4.3 3 1.7 1.4 0.9 1 0.9 1 1.1 1.6 4.2 5.3 3.5 2.9 2.8 2.4 1.6 0.9 1 1.2 0.9 1.1 1.2 1.5 1.6 2.7 3.8 4.8 4.8 5.8 8.2 8.2 2 9 6.2 3.2 2.2 3 3.8 3.3 2.3 2 1.4 1.1 0.7 0.9 1 1.8 2.3 6.1 9.2 3.5 3.4 3.2 2 1.3 1.2 1.7 1.3 1.5 1.2 1.5 1.9 2 3.5 3.4 3.7 4.4 4.3 4.3 6.2 3 9.4 6.1 2.8 2 2.7 3.6 3.4 2.8 1.9 1.6 1.4 1.2 1.2 1.5 2.1 2.3 4.4 7 4 2.8 2.8 2.5 1.1 1.1 1.3 1.3 1.4 1.1 1.6 1.9 2.3 2.9 3.6 4.7 4.7 4.8 6.3 6.1 4 8 8 4.5 2.7 3.7 4.4 3.9 2.9 1.8 1.3 0.7 0.6 0.8 1 1.4 1.8 2.6 5 3.4 2.8 2.6 2.2 1.4 1.1 1.1 1.5 0.8 1.2 1.2 1.6 1.9 3.5 4.5 4.5 5 5.9 6.9 8 5 8.4 6.1 4 3 3.7 4.1 3.9 2.7 2.1 1.4 1.5 1.2 1.3 1.4 2.2 2.3 3.8 8.5 5.3 3.3 3.4 2.5 1.7 1.2 0.8 0.9 0.7 1 1.1 1.7 1.7 2.5 2.7 3 4 3.8 5.2 6.1 6 11.4 4.8 3.7 3.4 4.7 5.9 5.4 3.7 2.7 1.9 1.1 1 1.4 1.8 2.4 3.1 4 8.3 6.1 3.6 3.1 2.4 1.1 0.9 0.8 0.6 0.6 0.7 0.7 1 1.4 1.8 2.4 3 3 3.3 4.2 4.8 7 12.7 3.6 3.6 2.4 2.5 3 2.9 2 1.7 1 0.8 0.8 1 1.4 2.5 3.1 4.2 11.5 10 5.2 3.7 2.3 1.3 1.1 0.8 0.8 0.8 0.8 1.1 1.6 1.7 2.8 3.5 3.9 3.4 3.2 3.9 3.6 8 11.5 5.1 2.8 1.9 2.1 2.2 1.9 1.5 1.2 0.6 0.7 0.5 0.7 1.1 2.5 2.7 3.8 9.1 6.5 4.2 3.7 2.6 1.3 0.9 1 1 1 1 1.4 2.4 2.8 4.1 5.4 5.7 5.3 4.3 4.7 5.1 9 7.8 4.3 2.7 2.1 2.4 3.6 2.5 1.7 1 1 0.8 0.6 0.9 1.1 1.8 1.8 3.4 4.5 3.4 3.1 3.3 3.1 2 1.6 2 1.7 1.6 2 2.5 3 3.3 4.9 6.4 6.2 5 4.2 4.4 4.3 10 6.7 6.3 2.1 1 1.7 3.3 2.4 1.4 1 0.6 0.8 0.5 0.6 0.8 1.2 1.2 2 2.7 2.7 2.9 2.4 2.7 1.7 1.5 1.4 1.7 1.8 2.3 2.4 3.3 3.5 5.2 5.5 5.4 7.9 8.4 7.6 6.3 11 6.8 5 1.7 0.9 1.1 2.3 2.4 1.7 1.3 1.2 0.8 0.7 0.8 1.1 1.2 1.7 4.6 4.6 2.9 2.9 2.7 2.8 2 1.8 1.8 1.9 1.6 1.9 2.3 2.8 3.6 4.9 4.9 5.2 6.5 7.3 6.9 5 12 7.5 6.5 2.8 1.4 2.1 4.1 4 3.5 2 1.5 1.2 0.9 1 1.1 2.1 2.3 4.2 5.3 2.6 2.9 2 2.1 1.8 1.5 1.6 1.7 1.5 1.5 1.8 1.9 1.8 2.4 3.4 4.4 5.4 7.4 6.4 6.5 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 9.2 5.5 13.4 13.2 12.2 13.1 8.6 8.5 4.5 3.3 3.4 1.6 1.4 0.7 0.5 0.4 0.1 0.1 0.1 0.1 0 0 0 0 0 0 1 9.4 5.2 11 9.2 8.9 11.8 8.6 9.9 5.6 4.4 6.1 2.7 2.4 1.3 1.1 0.9 0.3 0.4 0.2 0.3 0.1 0.1 0 0 0 0 2 9 4.8 11.8 12.2 10.7 12.7 8.4 9.1 5.1 4 5.2 2.4 1.9 0.9 0.6 0.5 0.1 0.1 0.2 0.1 0 0 0 0 0 0 3 9.4 5.7 12.9 12.3 10.7 11.3 7.9 9.2 5 3.7 5 2.3 2.1 0.8 0.8 0.4 0.1 0.1 0.1 0 0 0 0 0 0 0 4 8 4.8 12 13.2 12.6 14.1 8.8 9.6 5.3 4 3.5 1.8 1.2 0.4 0.3 0.2 0.1 0.1 0 0 0 0 0 0 0 0 5 8.4 6 14.6 16.8 15.7 14.7 9.6 6.7 3.1 2.2 1.2 0.6 0.2 0.2 0.1 0.1 0 0 0 0 0 0 0 0 0 0 6 11.4 7.6 18 16.5 14.6 14.6 7.2 5.5 2.1 1.3 0.9 0.2 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 7 12.7 8.4 18.5 16.6 14.9 12.4 8 5.1 2 0.9 0.4 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 11.5 6.3 15.8 15.8 14.1 13.8 8.4 6.7 3.2 1.7 1.4 0.5 0.3 0.2 0.1 0 0 0 0 0 0 0 0 0 0 0 9 7.8 4.6 13.2 14.8 13 14.3 9 9.1 4.5 3.3 3 1.1 1.2 0.4 0.3 0.2 0 0 0 0 0 0 0 0 0 0 10 6.7 3.4 9.4 9.8 10.8 14.2 9.8 10.9 6.4 5.5 4.9 2.7 2.3 1 0.7 0.5 0.3 0.1 0.2 0.2 0.1 0.1 0 0 0 0 11 6.8 3.8 9.9 9.6 9 11.1 8.8 11 6.4 5.4 6 3.2 3.3 2 1.2 1.2 0.4 0.3 0.3 0.2 0.1 0.1 0 0 0 0 12 7.5 3.8 10.5 9.2 8.9 10.9 9.1 11.3 7 5.2 6 2.8 2.8 1.6 1 0.8 0.3 0.4 0.4 0.1 0.1 0 0 0 0 0 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0.1 0.5 1.6 3.1 6 7 11.2 8.4 8.9 12.2 7.7 8.9 5.5 4.8 4.4 1.7 2 2.1 1.4 1 0.5 0.3 0.3 0.1 0.1 1 0 0 0.3 0.7 1.4 3.4 4.4 8.1 6.5 7.3 13.3 8.1 9.4 6.3 6.7 6.6 2.8 4.3 2.4 3.6 1.7 1.2 0.6 1 0 0 2 0 0 0.4 1.2 2.2 4.9 5.7 10 8 8.9 15.3 9.4 10.1 6.2 5 5.3 0.7 1.8 2.7 1.1 0.6 0 0.4 0 0 0 3 0 0.1 0.5 1.3 2.4 4.5 5.6 10.7 8.1 8.7 15.3 9.7 11.6 5.9 6.9 4.5 1.1 1.2 1.1 0.3 0.6 0 0 0 0 0 4 0 0.1 0.5 1.7 3.4 6.9 7.8 13.6 10.8 11.4 13.4 9 7.7 3.8 3 2.1 1 1.7 0.5 0.6 0.4 0.4 0 0 0 0 5 0 0.1 1.1 3.8 7.4 12.8 14.7 16.1 10.9 10.9 8 5 2.6 2.5 2.6 1.3 0 0 0 0 0 0 0 0 0 0 6 0 0.2 1.9 5.1 9.4 17.5 15 18.9 10.3 8.6 7.7 2.3 2.1 0.7 0.3 0 0 0 0 0 0 0 0 0 0 0 7 0 0.3 2.2 5.9 11.1 17.1 19.2 19.5 10.7 6.9 4.4 1.8 0.9 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0.1 1.3 3.6 6.8 12.5 13.2 16.9 11.4 8.9 10 4.3 4.1 3.2 1.5 0.5 0 0.3 0.4 0.5 0.6 0 0 0 0 0 9 0 0.1 0.7 2.2 4.1 8.2 9.1 14.8 10.4 10.8 12.9 6.3 9.6 3.8 3.2 2.9 0.8 0 0.3 0 0 0 0 0 0 0 10 0 0 0.3 0.8 1.9 4.5 5.5 9.9 8.1 10 11.8 9 9.8 5.4 4.9 3.8 2.6 1.5 3 2.5 1.9 1.2 0.6 1.1 0 0 11 0 0 0.2 0.6 1.2 2.8 3.9 7.9 6.5 7.8 11.5 8.4 11.5 8.4 6.5 7.7 3.2 2.9 3.4 1.8 1.2 0.9 0.8 0 0.4 0.4 12 0 0 0.3 0.7 1.3 3 4.4 8.9 7.8 8.2 12.5 7.9 10.5 7.5 5.9 5.8 2.3 3.9 4.2 1.8 1.9 0.5 0.3 0 0 0.5 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 360 360 160 160 1 350 360 350 350 350 360 360 350 350 40 350 350 50 160 360 350 360 360 360 350 350 360 360 330 2 160 160 160 160 160 160 160 160 360 160 160 160 160 300 160 160 160 360 160 150 160 160 160 160 3 350 350 160 160 350 340 160 350 350 320 330 160 160 160 360 360 360 360 360 360 160 160 160 350 4 340 360 360 340 350 360 350 360 340 360 310 350 350 360 360 360 360 360 160 350 360 360 350 360 5 160 160 160 360 360 160 160 160 160 330 160 160 160 170 160 160 160 160 160 160 360 160 160 160 6 160 50 50 50 50 40 350 40 40 40 50 160 160 160 160 160 170 160 160 160 160 160 160 160 7 160 160 160 160 160 160 160 160 160 160 160 170 160 160 160 160 170 170 160 170 170 160 160 160 8 160 330 160 160 160 160 330 160 160 160 160 160 160 160 160 170 170 160 160 160 160 360 160 160 9 340 310 320 320 320 310 330 300 310 300 310 320 320 310 310 310 310 320 310 360 340 310 320 330 10 330 340 330 340 350 350 330 340 340 300 330 330 310 310 350 350 340 340 350 340 340 340 340 330 11 350 340 340 350 340 150 340 330 340 340 330 340 320 300 330 300 310 350 340 350 340 340 350 350 12 340 360 360 350 350 340 360 340 160 160 320 350 340 340 160 340 340 320 350 340 350 340 340 360 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 4.77 4.85 4.97 5.03 5.23 5.17 5 5.45 5.49 5.39 5.48 5.47 5.4 5.79 5.8 5.66 5.73 5.55 5.25 5.1 7.12 7.3 5.13 4.92 1 7.88 9.15 9.06 9.34 9.45 9.57 9.25 9.62 8.64 4.82 8.91 8.16 4.15 6.61 7.12 8.6 8.25 7.79 7.54 9.12 9.39 9.04 7.48 7.59 2 5.43 6.06 5.59 6.37 5.87 6.71 6.08 6.69 7.65 6.23 6.7 6.61 6.01 6.88 6.6 5.97 5.58 8.12 6 4.81 5.96 6.45 6.56 6.43 3 9.06 7.36 5.62 4.5 8.08 7.82 5.13 7.12 8.17 6.8 8.46 4.88 4.97 5.72 7.17 7.46 7.59 8.27 8 7.7 5.62 5.54 5.73 6.99 4 6.96 6.03 6.4 6.21 7.05 5.75 7.15 6.95 6.75 5.26 5.6 6.4 6.67 6.88 6.23 6.7 6.44 7.85 5.17 8.1 7.1 7.26 7.28 6.59 5 4.61 3.96 4.65 5.38 6.2 3.86 4 4.59 3.95 6.07 5.27 5.27 5.45 5.24 5.91 6.19 5.95 5.69 5.67 4.79 6.13 4.58 4.22 4.02 6 3.87 3.16 3.1 2.88 2.75 3.01 4.84 3.53 3.68 3.78 3.58 4.59 5.19 4.81 5.08 5.25 4.81 4.88 4.58 4.72 4.67 3.99 4.09 3.73 7 3.85 3.92 4.15 4.06 4.57 4.68 4.34 4.92 4.74 4.82 4.75 4.42 5.05 5.18 4.75 4.88 4.76 3.99 4.74 4.23 4.06 4.2 4.3 3.66 8 3.91 3.29 4.62 4.33 4.36 4.53 4.22 5.06 4.85 4.79 4.65 4.7 4.84 5.11 4.86 5.03 4.25 5.06 4.81 4.56 4.97 5.51 4.02 5.14 9 5.74 4.18 6.08 4.68 5.27 5.65 6.81 4.57 4.72 4.05 5.6 6.17 5.95 6.87 7.31 4.75 6.79 6.8 6.91 6.66 7.33 5.19 5.26 5.22 10 8.12 7.74 8.06 9.01 8.95 9.43 6.88 9 9.33 5.18 7.14 7.49 6.39 6.38 9.16 7.82 8.19 10.25 8.6 9.29 10.51 8.23 8.32 7.25 11 9.9 9.04 8.2 9.02 9.26 3.95 9.75 7.22 9.48 9.71 8.8 10.18 7.39 7.02 8.45 7.25 7.91 9.88 10.49 9.6 9.73 8.35 9.95 9.61 12 8.92 9.14 8.66 7.91 9.47 9.34 8.29 9.05 7.13 6.59 7.36 9.49 8.63 10.42 8.04 10.06 8.7 7.3 9.65 7.66 9.22 9.4 10.01 8.08