Loading...
HomeMy WebLinkAboutSt-Marys-New_longterm-dataSAINT MARY'S (AWOS) AK - 702005 62 deg 04' N 163 deg 18' W - Elev 95m LST=GMT+99 hours *NT=-11 04/79-10/80 10/83-09/02 Adjusted to Alaska Timezone (GMT-9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 5.38 6.2 7.03 6.35 5.78 4.93 4.3 4.17 4.79 4.77 4.76 5.96 6.16 1979 5.16 -1 -1 -1 4.6 3.3 5.35 3.66 5.71 4.26 3.05 7.35 8.32 1980 5.51 5.35 6.13 4.6 6.4 -1 -1 -1 -1 -1 3.6 -1 -1 1983 7.28 -1 -1 -1 -1 -1 -1 -1 -1 -1 6.6 7.44 7.9 1984 5.41 6.65 6.18 6.95 6.37 4.45 4.02 4.53 3.42 3.29 4.63 6.5 7.82 1985 6.42 8.57 6.33 6.89 5.97 6.29 5.03 4.5 5.27 5.73 6.18 8.15 8.31 1986 5.87 5.27 7.14 5.94 5.6 5.85 4.93 4.89 5.45 7.12 5.3 6.61 6.95 1987 5.17 6.89 7.13 6.82 5.85 4.95 4.97 3.43 3.6 4.72 4.42 4.32 4.74 1988 5.78 8.68 9.98 5.55 6.15 4.79 4.24 4.45 4.9 4.33 5.41 4.94 5.87 1989 6 5.43 8.09 6.7 6.99 5.87 4.68 5.19 5.15 5.54 5.99 5.28 7.32 1990 5.44 8.28 4.87 6.26 5.53 5.21 4.3 4.61 5.82 5.1 4.62 5.2 7.14 1991 5.54 7.05 6.82 6.77 5.1 4.95 4.95 4.48 4.01 4.82 5.59 7.53 5.99 1992 4.68 4.84 3.5 4.31 -1 -1 -1 -1 -1 4.3 4.91 4.81 4.59 1993 5.89 5.97 8.65 6.81 5.17 5.17 4.31 4.3 5.29 5.73 5.36 7.31 6.82 1994 5.4 5.05 6.59 6.28 6.08 4.05 3.95 4.28 6.3 4.02 4.11 6.76 7.64 1995 5.1 5.68 7.16 5.16 6.18 4.76 4.2 3.75 3.73 4.65 4.62 3.72 7.56 1996 5.45 5.36 6.95 6.7 6.45 5.52 4.97 4.7 4.99 4.6 4.69 6.05 4.71 1997 4.84 5.14 6.88 5.29 4.81 4.79 3.94 3.57 4.72 4.34 4.05 5.92 4.66 1998 5.43 7.07 5.79 6.82 6.37 5.55 4.32 3.34 5.81 5.02 4.7 5.54 4.55 1999 5.08 6.87 6.14 5.94 6.46 4.37 4.16 4.75 4.39 4.82 3.29 5.59 4.34 2000 5.87 5.34 8.25 7.19 4.77 4.89 3.62 4.33 5.34 5.01 4.81 7.42 8.93 2001 5.41 6.64 6.98 6.37 5.99 5.37 4.95 4.47 4.74 4.39 4.43 5.88 4.34 2002 4.66 6.71 7.23 6.61 5.1 4.58 4.11 3.77 3.94 2.61 -1 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 224 356 441 316 251 136 86 86 133 139 160 297 379 1979 191 -1 -1 -1 66 30 149 34 168 91 46 445 1222 1980 304 439 213 155 182 -1 -1 -1 -1 -1 29 -1 -1 1983 416 -1 -1 -1 -1 -1 -1 -1 -1 -1 287 477 504 1984 275 445 304 350 317 109 74 110 86 70 150 592 728 1985 351 678 319 378 244 408 126 96 149 212 306 680 653 1986 257 247 407 247 240 204 139 162 173 363 196 357 444 1987 225 464 420 476 229 151 143 52 65 117 165 136 276 1988 296 625 1113 217 275 131 78 101 123 96 222 176 380 1989 285 301 585 359 439 198 87 124 118 196 260 293 530 1990 221 724 235 300 194 123 77 96 218 160 127 153 510 1991 224 503 422 351 175 116 106 76 69 119 207 442 318 1992 189 211 79 163 -1 -1 -1 -1 -1 108 175 158 274 1993 278 362 725 351 165 137 87 81 196 261 198 427 375 1994 250 189 420 364 239 73 70 97 254 97 119 474 659 1995 206 351 426 207 298 121 80 66 59 112 172 81 506 1996 217 218 422 335 303 180 121 113 139 140 143 277 192 1997 161 250 334 212 139 138 66 54 119 99 97 256 174 1998 206 350 224 292 315 168 94 38 214 156 143 231 236 1999 204 527 339 269 362 93 75 132 119 122 60 257 135 2000 268 248 541 415 144 137 54 91 169 152 177 386 641 2001 214 355 496 339 332 156 111 100 109 89 127 232 117 2002 138 339 441 327 170 103 79 66 67 29 -1 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 113726 9266 8429 9166 8764 10376 10193 10398 10762 8607 9913 8983 8869 1979 112 0 0 0 3 4 2 10 40 30 6 13 4 1980 32 15 10 4 2 0 0 0 0 0 1 0 0 1983 706 0 0 0 0 0 0 0 0 0 258 220 228 1984 2889 257 239 257 235 235 239 276 182 250 269 237 213 1985 2968 248 242 248 241 264 246 241 253 258 262 229 236 1986 3176 249 235 253 255 249 325 286 335 259 253 225 252 1987 2770 234 217 256 237 243 239 238 235 243 210 204 214 1988 2830 245 232 225 218 240 236 203 237 251 243 249 251 1989 3429 261 248 298 293 321 294 303 300 276 286 266 283 1990 4302 295 293 348 324 341 347 342 360 522 629 277 224 1991 4001 263 264 255 272 284 305 332 296 538 580 211 401 1992 2772 201 64 45 0 0 0 0 0 318 708 709 727 1993 8081 742 664 743 718 742 706 662 666 481 692 632 633 1994 8449 725 628 721 681 738 691 732 741 703 731 654 704 1995 8217 674 636 681 697 718 688 702 656 690 685 676 714 1996 7415 707 682 547 526 493 425 531 730 707 686 674 707 1997 8443 720 688 690 693 735 698 737 697 702 714 717 652 1998 8175 666 622 710 703 732 725 589 728 687 709 673 631 1999 8620 681 648 725 712 808 740 763 764 677 647 719 736 2000 8194 700 681 731 709 727 715 726 737 336 678 715 739 2001 7619 737 505 714 690 563 678 694 714 655 666 683 320 2002 10526 646 631 715 555 1939 1894 2031 2091 24 0 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 3777 284 229 269 281 353 381 382 386 288 334 298 292 1 3798 315 294 313 279 349 338 343 365 280 338 306 278 2 3693 302 267 287 285 320 312 327 354 283 347 313 296 3 3755 282 248 264 281 370 360 369 374 300 337 298 272 4 3790 307 280 318 287 330 347 341 362 293 330 299 296 5 3801 300 273 289 287 355 341 362 379 281 344 298 292 6 3988 281 250 266 294 399 393 389 438 327 340 306 305 7 4388 340 295 329 385 432 420 425 446 332 365 308 311 8 5150 362 341 370 402 546 492 514 513 426 468 352 364 9 6094 491 461 486 485 577 539 555 554 463 535 474 474 10 6175 519 489 533 491 554 540 549 556 453 525 494 472 11 6006 523 491 515 470 533 520 514 522 423 516 493 486 12 6046 473 433 470 480 568 555 563 551 471 525 498 459 13 6103 521 495 541 498 537 517 553 523 446 510 475 487 14 5873 494 461 484 468 543 510 490 539 441 514 451 478 15 5874 484 446 482 458 545 528 536 523 435 486 476 475 16 5888 515 458 525 464 529 486 503 508 434 516 475 475 17 5377 488 455 493 410 421 444 446 462 364 475 468 451 18 4507 378 328 344 318 370 402 425 447 376 388 358 373 19 4153 355 318 346 299 358 369 376 412 312 359 324 325 20 3804 317 288 300 265 320 349 349 376 294 345 296 305 21 3948 289 258 298 290 383 364 394 414 321 338 300 299 22 3932 330 303 337 308 333 357 332 374 294 347 312 305 23 3806 316 268 307 279 351 329 361 384 270 331 311 299 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 4.78 5.59 7.05 6.36 5.26 3.91 3.35 3.44 4.22 4.14 4.15 5.92 5.92 1 4.85 5.84 6.84 6.04 5.37 3.97 3.23 3.41 4.01 4.08 4.15 5.94 6.12 2 4.81 5.9 6.84 6.13 5.34 4.05 3.11 3.21 4.07 3.94 4.1 5.83 5.93 3 4.78 5.87 7.02 6.28 5.18 3.98 3.33 3.34 3.92 4.19 4.19 5.91 6 4 4.86 5.81 6.87 6.13 5.26 4.07 3.23 3.27 4.25 4.08 4.18 6.04 5.98 5 4.89 5.95 7.08 6.2 5.16 4.06 3.29 3.47 4.27 4.23 4.16 5.83 6.17 6 4.83 5.86 7.08 6.12 5.11 4.18 3.22 3.6 4.28 4.26 4.22 5.9 6.1 7 5.04 6.24 7.19 6.12 5.29 4.67 3.74 3.72 4.46 4.24 4.3 5.83 6.12 8 5.07 5.95 7.14 6.22 5.21 4.77 4.11 3.9 4.51 4.44 4.35 5.66 6.16 9 5.33 6.2 6.99 6.15 5.57 4.94 4.31 4.1 4.69 4.58 4.48 6.06 6.47 10 5.51 6.31 6.95 6.37 5.87 5.16 4.42 4.25 4.98 4.86 4.73 5.99 6.54 11 5.63 6.45 6.97 6.38 6.02 5.23 4.47 4.38 5.14 5.25 4.96 6.03 6.44 12 5.71 6.44 7.15 6.54 6.11 5.4 4.67 4.52 5.18 5.41 5.39 6.07 6.38 13 5.82 6.47 6.98 6.62 6.25 5.5 4.82 4.57 5.19 5.49 5.57 6.14 6.35 14 5.9 6.69 7.11 6.58 6.29 5.65 4.99 4.6 5.39 5.51 5.64 6.16 6.35 15 5.92 6.51 7.13 6.71 6.4 5.69 5.11 4.91 5.23 5.6 5.74 6.07 6.37 16 5.93 6.44 7.05 6.6 6.5 5.74 5.15 4.91 5.46 5.62 5.67 5.96 6.13 17 5.92 6.48 6.9 6.65 6.28 5.83 5.28 4.85 5.51 5.48 5.32 6.02 6.26 18 5.74 6.31 7.22 6.38 6.3 5.79 5.21 4.97 5.46 5.12 4.9 5.96 5.87 19 5.57 6.2 7.12 6.13 6.15 5.52 5.13 4.93 5.27 4.89 4.62 5.62 5.56 20 5.43 6.03 7.12 6.22 5.76 5.21 5 4.57 5.05 4.59 4.32 6 5.85 21 5.18 5.91 7.07 6.19 5.46 4.67 4.55 4.38 4.52 4.22 4.41 6.07 5.91 22 5.03 5.89 6.91 6.14 5.55 4.1 3.97 3.68 4.22 4.16 4.38 5.8 5.94 23 4.91 5.89 6.95 6.25 5.35 3.96 3.61 3.51 4.34 4.01 4.22 5.77 5.93 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 177 268 436 306 199 70 43 58 108 111 122 279 325 1 190 315 405 268 221 75 42 55 100 108 117 291 368 2 185 301 402 293 211 88 41 56 102 90 112 266 332 3 182 278 435 313 182 80 47 60 89 107 120 295 371 4 192 300 412 293 199 82 41 53 116 97 121 302 365 5 192 321 430 311 200 88 44 58 112 110 115 268 371 6 186 300 469 302 184 89 45 67 109 106 119 288 375 7 202 366 486 306 216 119 60 68 124 100 131 260 366 8 200 321 489 328 198 128 85 68 114 122 141 271 355 9 232 369 472 318 247 140 86 77 131 119 140 346 433 10 247 390 455 337 267 155 95 87 145 146 158 332 444 11 253 390 459 341 268 152 94 90 148 164 181 329 430 12 254 403 471 351 295 161 104 100 152 171 207 322 422 13 262 393 441 353 302 179 110 100 157 182 224 317 402 14 261 420 442 337 292 190 116 103 173 182 215 292 408 15 260 396 433 339 308 189 119 131 148 196 219 295 409 16 257 394 419 320 317 195 122 119 165 193 208 282 369 17 260 391 399 340 293 186 131 111 162 179 185 304 407 18 238 372 461 287 279 180 125 125 155 152 166 298 335 19 223 360 442 279 283 152 120 110 153 135 151 242 299 20 211 325 425 284 239 135 112 99 130 127 126 278 333 21 198 314 433 292 206 113 89 88 114 105 142 313 335 22 198 310 415 290 222 82 64 57 101 115 148 293 335 23 191 330 419 293 210 76 48 59 109 95 129 275 337 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 5.65 5.35 4.69 4.11 4.17 5.18 6.76 7.08 7.36 8.05 7.76 6.72 6.01 6.1 6.04 6.23 6.3 5.66 5.5 5.29 5.31 5.04 5.09 5.06 4.87 4.31 4.07 4.22 4.16 4.6 4.89 4.82 4.89 5.02 5.38 5.69 5.65 1 0 5.6 5.6 5.6 4.8 5.1 6.8 8.1 8.2 8.4 9.3 8.8 7.9 7 7.6 8 8.3 8.8 7.2 6.8 6 6.5 5.5 5.4 5.8 5.2 3.8 4.1 4.7 4 5.6 5.6 5.1 4.8 4.8 5.5 5.5 5.6 2 0 5.8 5.9 5.6 4.7 4.7 6.6 8.7 8.8 9.6 10 9.6 7.7 7.3 6.8 6.5 7.8 7.7 7 7.3 6.2 6 5.8 5.8 6.7 6.4 4.8 4.4 5.6 5.1 4.4 4.9 5.1 5.3 6 6.7 6.6 5.8 3 0 6.1 6.5 5.4 4.3 4.5 5.5 7.5 7.9 8.3 8.9 8.3 7.4 6.9 6.5 6.9 6.8 6.7 6.6 5.7 5.5 5.7 4.6 5.5 4.7 4.6 4.6 4.2 4.8 5.3 5.8 6.3 6.2 6.1 5.4 6.2 6.2 6.1 4 0 6.8 6.4 5 4.1 3.8 4.4 5.7 6.3 6.5 7.6 7.5 6 6.3 7.5 7.7 7.1 7.9 6.5 6.2 5.9 6.2 5.9 6.1 6 5.9 4.7 4.4 4.7 5.1 5 5.9 5.3 5.8 5.9 5.8 6.4 6.8 5 0 5.9 5 4.1 3.5 3.3 3.5 4 5.1 5.7 5.9 5.6 5.7 5.8 6 5.8 5.5 5.7 5.1 5.3 5.3 5.2 4.7 5.3 4.8 4.6 4.4 4.3 4.3 4 4.9 5.2 5 5.3 5.3 5.6 6 5.9 6 0 4.9 4.4 3.7 3.5 3 3.4 4 4.3 4.8 5.5 5.2 5.2 4.7 4.7 4.6 4.7 4.7 4.4 4.3 4.6 4.8 4.7 4.4 4.7 4.7 4.2 4 3.9 3.9 4.5 4.5 4.6 4.7 4.7 4.9 5.3 4.9 7 0 4.5 3.8 3.3 3.2 2.9 3.2 3.8 3.9 4.1 4.3 4.5 4.5 4.3 4.6 4.8 4.7 4.9 5 4.8 4.8 5 4.8 4.9 5 4.8 4.2 4.1 3.8 3.7 4.1 4.2 4.2 4.3 4.5 4.7 4.8 4.5 8 0 4.6 4.4 4 3.7 4 4 4.3 4.4 4.8 5.4 6.2 5.3 5.2 6 5.9 6.1 6.2 6.1 6 5.8 5.7 5.4 5.4 5.3 5 4.8 4.1 4.6 4 4.4 4.5 4.8 4.5 4.8 4.8 4.7 4.6 9 0 5.5 4.9 4.1 3.7 3.8 4.6 5.1 5.9 6.4 5.6 5.8 4.9 5.1 5.1 5.2 5.8 6 5.7 5.2 5.2 4.8 5.2 4.8 5.1 4.9 4.4 3.7 3.9 4 4.5 4.6 4.6 4.7 5.2 5.2 5.6 5.5 10 0 5.7 5.2 4.5 4 4.1 4.5 5.6 6.2 6.1 6.5 7 5.8 5.5 5.6 5.7 6.1 6.1 5.6 5.6 4.9 5 5.2 4.6 4.5 4.2 3.6 3.9 4 4.2 4.2 4.4 4.2 4.3 4.6 5 5.6 5.7 11 0 5.3 5.2 4.4 4.1 4.3 5.8 7.1 7.4 7.4 8.2 8.8 7.8 6.6 6.8 6.6 7.3 7.2 6.1 6.1 5.5 5.4 4.7 5.8 5.1 5.3 3.9 3.8 4 4 4.9 6.1 5.7 4.9 5.2 5.4 5.9 5.3 12 0 5.4 5.1 4.5 4.2 4.7 5.9 8.4 8.6 8.8 10.2 9.4 8.2 6.7 6.7 6.7 7.3 7.4 4.7 4.8 4.9 4.1 3.6 4.1 4.8 4.8 3.6 4.2 3.9 3.7 4.4 5 4.5 4.5 4.6 5.2 5.6 5.4 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 5.72 3.96 3.68 4.06 4.27 3.92 3.62 3.97 3.99 3.77 4.42 4.63 4.39 3.37 2.5 2.08 2.36 2.71 2.52 2.61 2.34 2 1.71 1.72 1.56 1.5 1.39 1.23 1.36 1.43 1.77 2.3 2.28 2.36 2.32 2.73 3.17 3.96 1 8.5 4.1 3.9 6.7 7.9 6 6.5 6.7 5.5 5.3 5.2 5.2 5.6 3.2 2.1 1.8 1.8 2.1 1.8 1.7 1.7 1.4 0.8 0.8 0.5 0.4 0.3 0.4 0.4 0.5 0.8 1 0.9 1.2 1.3 1.9 2.5 4.1 2 4.8 3.9 3.7 5 4.4 4.3 4 5.6 6.4 5.8 9.2 8.6 7.2 4.9 2.7 1.8 2.1 1.5 1.1 1.2 0.9 0.9 0.7 0.6 0.3 0.3 0.5 0.3 0.5 0.8 0.7 0.8 1 1.3 1.5 2.4 3.1 3.9 3 3.4 4.2 4.8 5.3 5.9 5.5 4.8 6.5 6.2 6.1 6.9 6.4 4.5 3.1 1.9 1.6 1.7 2.3 1.5 1.1 1 0.8 0.6 0.8 0.5 0.5 0.7 0.6 0.7 0.8 1.2 1.5 1.5 1.8 2 2.4 2.5 4.2 4 3.8 7.3 6.5 5.5 5.3 4.1 3.7 3.9 3.6 3.9 4 4.3 3.2 2.6 2.5 1.7 1.9 2.7 1.9 1.8 1.7 1.3 1.1 1.1 0.9 1.1 1 0.8 1.1 1.3 1.2 1.9 2.5 2.6 2.7 3.3 4.1 7.3 5 3.8 4.5 3.6 3.5 3.2 3.2 2.5 2.1 2.3 2.6 2.6 3.5 4.4 4.6 3.4 2.5 3.2 3.7 3.2 2.9 2.3 1.9 1.7 1.7 1.6 1.6 1.6 1.7 1.6 1.6 2 2.9 2.8 3.1 2.7 3.3 4.3 4.5 6 5 4.4 3.8 3 3.1 2.4 2.3 1.7 1.9 2.2 2.6 2.8 3 2.4 2.1 2.2 2.2 3.1 3.3 3.1 2.3 2.4 2.4 2.3 2.2 2.7 2.1 1.8 2 1.9 3 3.8 4.2 4.1 3.6 3.4 4.3 4.4 7 6.6 2.4 2.2 2 1.8 1.5 1.2 1.1 1.5 1.4 1.9 2.3 2.9 2.9 2.8 2.7 3.1 3.9 4.5 4.7 4.3 4.5 4 4.3 4 2.6 2.4 1.9 2.2 1.9 2.6 3.6 3.1 3.1 2.8 3.2 3.1 2.4 8 5.2 2.3 2.6 2.9 3.4 3.5 2.1 1.9 1.9 1.7 1.9 2.1 2.2 2.3 2.5 2.6 2.9 3.1 4.4 5 4.4 3.7 2.8 3.5 3.6 3.7 2.7 2.2 2.3 2.2 2.6 3.1 2.7 2.9 2.1 2.1 2 2.3 9 5.6 3.9 2.9 3 2.8 3.4 3.1 3.4 3.6 3.6 3.9 4.3 4.4 3.8 2.4 2.1 2.9 3.3 3.1 3.3 2.8 2.1 2 1.9 1.7 1.7 1.8 1.7 1.9 1.9 2.6 2.7 2.8 2.4 2.2 2.4 2.6 3.9 10 6.9 4.4 4.1 4.1 4.6 4.4 4.4 4.2 4.3 2.9 3.1 3.4 2.5 3 2.2 1.9 2.1 2.3 1.9 2.5 3 2.3 2.2 1.3 1.2 1.4 1.4 1.6 2.1 2.2 2 2.3 2.4 2.2 3.2 3.4 3.6 4.4 11 6.3 3.3 3.4 3.9 4.4 4.4 4.6 5.2 5.4 5.2 6.1 7.1 7.8 4.1 3 2 2.3 2.4 1.8 1.7 1.7 1.2 1.2 1 0.8 0.6 0.9 0.6 0.5 0.7 1.2 1.7 1.4 1.4 1.7 2.4 2.7 3.3 12 8.9 3.2 3 4.8 5.2 5.1 5.1 6.8 6.9 5.9 7.4 7.4 6.3 3.9 2.3 2.1 1.8 1.6 0.8 1.2 1 0.7 0.4 0.5 0.5 0.5 0.6 0.6 0.5 0.8 1 1.5 1.5 1.6 1.7 2.6 2.8 3.2 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 5.7 3.8 12.2 14.3 13.2 13.1 10.1 8.4 5.3 4.3 3.6 2.2 1.7 0.9 0.6 0.4 0.1 0.1 0.1 0 0 0 0 0 0 0 1 8.5 2.9 10.1 10.2 9.3 9.7 8.9 9.1 6.7 6.4 6.3 3.9 3.4 1.5 1.4 1.3 0.2 0.2 0.2 0 0 0 0 0 0 0 2 4.8 2 7.3 8.3 9 10.5 9.6 9.8 7.1 8.3 7.6 5.4 4.4 2.2 1.5 1.2 0.5 0.2 0.3 0 0.1 0 0 0 0 0 3 3.4 2.2 8.6 10.9 11.2 12.5 10.7 11 7.5 6.5 5.7 3.8 2.8 1.7 1.1 0.3 0.1 0.1 0 0 0 0 0 0 0 0 4 3.8 2.8 10.7 13.2 12.5 13.6 10.6 9.6 6.9 5.5 4.8 2.4 1.3 0.9 0.5 0.7 0.1 0.1 0.1 0 0 0 0 0 0 0 5 3.8 3.4 12.4 15.9 16.3 15.9 12.5 9.6 4.5 2.8 1.6 0.7 0.3 0.1 0 0.1 0 0 0.1 0 0 0 0 0 0 0 6 5 4.7 14.6 20 17.8 15.9 10.3 6.7 2.6 1.5 0.6 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 6.6 5.4 16.6 18.9 16 16 9.7 5.7 2.5 1.3 0.8 0.3 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 8 5.2 4.5 13.5 16.2 14.9 15 11.1 8.4 4.6 2.8 2.1 0.9 0.4 0.2 0.1 0 0 0 0 0 0 0 0 0 0 0 9 5.6 5 14.5 16.2 14.7 13.3 10.2 8.6 4.7 2.9 2.4 0.9 0.8 0.2 0.1 0 0 0 0 0 0 0 0 0 0 0 10 6.9 5.1 15.8 15.8 13.7 12.5 9.3 6.8 4.9 3.3 2.4 1.8 0.9 0.5 0.2 0.1 0 0 0 0 0 0 0 0 0 0 11 6.3 3.3 10.6 12.2 10.4 10.7 9.6 9.1 7 6.4 5.3 3.6 2.5 1.4 0.8 0.5 0.2 0.1 0.1 0 0 0 0 0 0 0 12 8.9 3.4 10.3 11.2 10 9.7 8.4 7.7 5.4 5.1 5.3 4.4 4.3 2.4 1.3 1.3 0.5 0.2 0.2 0 0.1 0 0 0 0 0 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0 0.5 1.5 3 5.6 7.5 10 9.1 10.3 11.8 9.8 9.9 6.3 5 4.7 1.7 1 1.4 0.3 0.4 0 0 0.1 0 0 1 0 0 0.3 0.7 1.4 2.8 4.3 7 7.5 10 13.3 10.8 12.7 6.9 7.7 8.6 1.8 2 1.7 0.4 0 0 0 0 0 0 2 0 0 0.2 0.5 1.1 2.4 3.7 6.2 6.4 10.6 13 12 13.2 8.2 6.9 6.8 3.2 1.5 2.6 0.5 0.8 0 0 0.2 0 0 3 0 0 0.2 0.9 1.9 3.9 5.8 9.5 9.4 11.4 13.4 12 11.7 8.6 6.8 2.6 0.6 0.6 0.4 0.3 0 0 0 0 0 0 4 0 0 0.4 1.3 2.6 5.3 7.1 10.2 10.7 11.9 14 9.5 7 5.5 4 6.3 1.2 1.5 1.2 0.2 0.2 0 0 0 0 0 5 0 0.1 0.8 2.8 6.2 11.1 15.1 18.4 12.6 11.1 8.3 5.1 3.3 1.1 0.3 1.6 0 0 1.8 0 0.4 0 0 0 0 0 6 0 0.1 1.5 5.5 10.3 17.1 18.9 19.4 11.3 8.6 4.6 1.5 0.7 0.2 0.2 0 0.3 0 0 0 0 0 0 0 0 0 7 0 0.1 1.6 5.1 9.4 17.3 18 16.8 10.9 7.7 6.4 3.4 1.6 0.7 0 0 0 0 0 0 0 0 0 0 0 1.1 8 0 0.1 0.9 2.9 5.7 10.5 13.4 16 12.7 10.9 10.9 6.1 4 2.3 1.7 0.8 0.6 0 0.5 0 0 0 0 0 0 0 9 0 0.1 0.9 2.8 5.3 9 11.7 15.9 12.5 10.9 12 5.9 7 2.7 1.9 0.7 0.7 0 0 0 0 0 0 0 0 0 10 0 0.1 0.8 2.4 4.5 7.6 9.6 11.4 11.6 10.9 10.8 10.5 7.5 4.7 2.7 1.8 0.8 0.8 0.2 0.3 0.6 0.4 0 0 0 0 11 0 0 0.3 1 1.8 3.6 5.5 8.3 9.1 11.8 13.2 11.7 11.1 7.6 5.3 4 2.4 1 1.2 0.7 0.2 0 0 0 0 0 12 0 0 0.2 0.8 1.4 2.6 3.8 5.6 5.6 7.5 10.3 11.5 14.9 10.4 7 8.3 3.8 1.4 2.6 0.3 1.6 0 0 0.3 0 0 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 30 100 30 30 30 100 100 30 100 60 60 60 60 360 360 360 360 360 360 100 10 10 90 30 1 30 30 30 90 30 30 30 110 60 30 60 60 60 50 50 60 50 60 50 30 30 40 80 30 2 100 100 100 100 100 90 90 100 100 60 100 90 60 90 70 90 90 90 90 90 110 90 90 110 3 90 90 30 90 90 90 100 40 70 60 60 60 70 90 70 60 60 10 10 20 90 100 100 80 4 30 90 30 30 30 20 20 20 360 20 360 360 360 360 360 360 360 360 360 360 10 10 30 30 5 30 20 40 40 30 40 30 120 40 110 110 110 120 120 160 160 360 350 360 350 350 350 360 30 6 30 10 30 40 40 40 10 30 20 10 160 110 130 170 170 180 310 210 350 300 320 310 10 320 7 220 190 40 170 170 170 170 20 180 170 210 160 160 200 220 250 190 240 190 240 330 300 180 320 8 40 40 200 40 40 20 180 180 30 30 170 190 170 180 200 180 180 180 180 240 250 180 10 180 9 150 190 40 110 110 60 110 60 50 40 80 100 70 100 80 100 360 120 320 360 10 360 40 180 10 30 30 30 30 30 30 50 40 50 30 50 20 60 360 10 20 360 360 360 360 10 360 30 40 11 110 110 110 100 110 100 110 110 90 80 70 60 70 110 60 90 90 90 110 100 110 100 100 100 12 90 70 90 30 90 90 90 110 110 60 60 100 70 60 60 60 60 70 70 100 80 100 20 100 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 3.66 7.59 3.55 3.57 3.53 7.97 7.56 3.65 7.36 7.83 7.88 7.82 7.92 5.94 6.1 6.32 6.47 6.19 6.69 7.77 5.78 5.48 8.33 3.68 1 4.91 5.35 4.7 9.08 4.45 4.3 4.63 8.96 5.86 5.53 9.16 9.46 9.66 7.73 8.74 8.87 7.77 8.84 7.24 4.12 4.58 4.87 8.38 4.35 2 9.59 9.54 9.53 10.6 9.62 10.47 10.22 9.37 9.32 10.37 8.81 10.39 9.8 9.84 8.41 9.51 9.31 9.12 9.2 10.53 7.43 9.78 10.03 7.83 3 8.6 9 3.62 9.67 9.17 9.65 8.52 3.95 8.23 8.59 8.38 8.71 8.88 9.5 8.32 8.68 8.17 7.78 6.94 6.03 8.54 7.95 9.2 8.38 4 3.14 8.02 3.97 3.59 3.66 4.54 3.74 4.95 5.7 4.72 5.81 6.36 6.94 7.52 7.13 7.66 7.3 7.28 7.59 7.51 6.11 6.05 4 3.89 5 3.08 3.35 2.9 3.17 3.03 2.73 3.31 5.54 3.71 6.09 6.01 5.63 5.66 6.38 5.99 6.65 6.94 7.47 7.77 6.93 6.87 6.06 4.93 3.05 6 3.21 2.94 3.04 2.8 2.99 2.75 3.4 3.5 3.72 4.19 5.06 5.53 5.5 4.76 4.79 5.88 6.18 4.84 7.56 6.41 5.7 5.48 4.69 3.75 7 5.5 3.96 2.61 5.17 4.17 4.73 4.95 2.99 4.13 5.01 4.58 5.64 5.06 4.66 4.3 4.37 5.29 4.8 5.53 4.89 5.38 3.77 4.06 3.37 8 3.13 3.22 5.15 2.82 3.45 3.21 5.26 5.44 3.08 4.44 5.94 4.83 6.16 6.07 5.53 6.24 6 6.05 6.18 5.1 4.31 5.84 3.66 5.5 9 5.52 5.67 2.91 4.03 4.95 5.58 4.17 5.27 5.45 3.95 6.97 6 6.48 6.16 7.05 6.67 6.73 5.67 4.74 5.19 4.06 5.06 2.91 5.11 10 3.05 2.97 3.39 3.14 3.21 3.18 3.21 4.24 4.65 3.52 4.82 4.1 6.44 5.88 6.85 6.34 6.48 6.13 6.83 4.94 4.61 5.2 3.41 3.37 11 7.25 7.77 7.65 8.26 8.14 9.43 8.17 7.46 8.22 8.07 8.31 8.09 7.8 7.61 8.34 7.79 7.72 7.87 7.79 7.91 8.23 9.55 9.45 9.04 12 10.24 8.23 10.85 4.06 12.12 10.88 11.54 7.73 8.02 10.02 10.39 9.36 8.77 9.26 9.84 9.55 9.4 8.79 9.46 9.44 8.15 9.38 4.7 10.11