Supplement to the California
ZEV Investment Plan
Cycle 1
JUNE 29, 2017
1 Supplement to the California ZEV Investment Plan
Table of Contents
1 Introduction .......................................................................................................................................................... 2
2 The ZEV Investment Commitment ........................................................................................................................ 3
3 10-Year Vision ....................................................................................................................................................... 5
3.1 Differences between the Cycle 1 National and California ZEV Investment Plans ........................................ 8
4 Additional Information on the Cycle 1 California ZEV Investment Plan ................................................................ 9
4.1 A High-speed Highway Network .................................................................................................................. 9
4.2 Building a Green City for ZEV Access .......................................................................................................... 10
4.3 Community Charging .................................................................................................................................. 11
4.4 Brand-Neutral Public Education and Outreach Activities .......................................................................... 13
4.5 ZEV Access Initiatives ................................................................................................................................. 14
4.6 Commitment to Workforce Development and Supplier Diversity ............................................................. 15
4.7 Summary of Investments Consistent with CARB Priorities ........................................................................ 15
5 Additional Steps to Support Disadvantaged, Low -income, and Underserved Communities .............................. 17
5.1 Expanding Community Charging to Include the Fresno Metro Area ......................................................... 17
5.2 Focus Education in CARB-prioritized Communities .................................................................................... 17
5.3 Increasing Access to a High Speed Highway Charging Network ................................................................ 18
5.4 Participating in Efforts to Identify Market Barriers .................................................................................... 19
6 Planning, Transparency, and Coordination ......................................................................................................... 20
6.1 Partnerships ............................................................................................................................................... 20
6.2 Additional Information on Infrastructure Planning Processes ................................................................... 22
6.3 Additional Information on the Green Cities Selection Process .................................................................. 23
6.4 Response to Comments ............................................................................................................................. 25
6.5 Regular Updates on Implementation ......................................................................................................... 27
7 Hydrogen Fuel Cell Vehicle Technology .............................................................................................................. 29
8 Costs and Other Data Requests .......................................................................................................................... 31
8.1 Creditable Costs ......................................................................................................................................... 31
8.2 Electrify America’s Business Model ........................................................................................................... 31
8.3 Data Sharing ............................................................................................................................................... 31
8.4 Monitoring and Maintenance of ZEV Investments .................................................................................... 32
8.4.1 Network Monitoring .......................................................................................................................... 32
8.4.2 Call Center ......................................................................................................................................... 32
8.5 On-going Maintenance............................................................................................................................... 33
8.6 Timelines .................................................................................................................................................... 33
9 Sources ................................................................................................................................................................ 35
2 Supplement to the California ZEV Investment Plan
1 Introduction
Electrify America welcomes the opportunity to provide additional information on its plan to invest $200
million in the first 30-month cycle to support Zero Emission Vehicle (ZEV) use in California, consistent
with the ZEV Investment Commitment laid out in Appendix C to the 2.0-Liter Partial Consent Decree
entered by the U.S. District Court for the Northern District of California on October 25, 2016. We are
proud of the research, analysis, and consultation we have conducted over the past six months to bring
us to this point, and we believe this new information will help to demonstrate the substantial additional
benefits that this investment will produce for Californians from all communities.
There has been some confusion about the requirements applicable to the ZEV Investment Commitment,
but this Supplement will make one thing clear: Electrify America's Cycle 1 CA ZEV Investment Plan would
result in substantial investment in and benefit to underserved, low-income, and disadvantaged
communities that are among the State of California’s priorities because investing in these communities
often makes sound business sense. The Cycle 1 CA ZEV Investment Plan lays out a business investment,
not a penalty payment plan, but that investment is designed to advance the goal of increased ZEV use
shared by both Electrify America and California.
This supplement will also add new investments to the Cycle 1 ZEV Investment Plan. We have added the
Fresno metro area as a focus for community charging investments, developed an education and
outreach proposal targeted at the unique barriers to ZEV use in low-income and disadvantaged
communities, and presented a new strategy to explore the use of more affordable pre-owned ZEVs.
Finally, this Supplement will provide additional information on how Electrify America intends to plan and
operate. We describe ongoing work with the ZEV charging industry, utilities, local leaders, and experts
to ensure that Electrify America's investments are as impactful as possible. We present more
information on our approach to future planning cycles, where we will evaluate emerging ZEV
technologies, such as heavy duty hydrogen fuel cell technologies, for potential investment. Finally, we
provide a detailed description of how Electrify America plans to oversee and maintain its investments.
Electrify America is committed to investing in the infrastructure and education that California needs to
reach 1.5 million ZEVs on the road by 2025, helping the state reduce its dependence on foreign oil, and
helping consumers save money at the pump, while dramatically reducing smog and greenhouse gas
emissions that endanger the health and welfare of Californians. Electrify America intends to make
investments that supply a much needed benefit to all Californians, including low and moderate income
residents, and those who live in disadvantaged communities.
Electrify America has begun investing in the rest of the United States and has already installed its first
charging stations on the East Coast. We urge rapid consideration of this supplement, and quick approval
of the Cycle 1 CA ZEV Investment Plan, so we can begin to create jobs, reduce emissions, and provide
much needed services to all Californians.
3 Supplement to the California ZEV Investment Plan
2 The ZEV Investment Commitment
Starting in December 2016, Electrify America solicited proposals, recommendations, and comments
from stakeholders regarding the Cycle 1 CA ZEV Investment Plan, and these comments and
recommendations have significantly informed Electrify America’s investment priorities. However,
Electrify America is concerned that some comments submitted to CARB on the Cycle 1 CA ZEV
Investment Plan demonstrate a misunderstanding regarding the requirements and intent of the ZEV
Investment Commitment included in Appendix C, as well as Electrify America’s plans within this space.
For example, commenters expressed the view that the ZEV Investment Commitment was a punishment
for pollution instead of an investment, urged CARB to require Electrify America to spend money in
locations and on programs without regard to whether such spending could be economically justified as
an investment, urged that CARB require investment for the purpose of benefitting specific communities,
and urged that CARB direct the specific location and nature of the Electrify America investment – often
without regard to the important consideration that investments be made where they are likely to be
well utilized.
The court-ordered, legally binding settlements reached between California, the Federal Government,
and VW will result in VW providing the State of California with $688 million, which the state can spend
as it desires, on the priorities of state government, without regard to investment prerogatives. This
includes $25 million that Volkswagen specifically agreed to provide to CARB for its programs to advance
ZEV deployment in low-income and disadvantaged communities, as well as $423 million for the NOx
Mitigation Trust, including contributions specified in both the 2.0 Liter and 3.0 Liter settlements.
According to the 2.0 Liter consent decree,
“the purpose of the Mitigation Trust is to
fulfill the Settling Defendants’
environmental mitigation obligations under
the Consent Decree. All payments to and
expenditures from the Mitigation Trust shall
be for the sole purpose of fulfilling the
Settling Defendants’ environmental
mitigation obligations under the Consent
Decree.” The Consent Decree explicitly
directs that this funding should be spent –
by the State and the Trustee without any
influence or control by Volkswagen – on
action that “mitigates the impacts of NOx
emissions on communities that have
historically borne a disproportionate share
of the adverse impacts of such emissions.”
In contrast, in Appendix C, Volkswagen committed to make an $800 million investment which would
advance the use of ZEV technology in the state of California, but, in the words of CARB Chairman Mary
Nichols:
Appendix C, the ZEV investment settlement, is not either a civil penalty or mitigation. It does
commit Volkswagen to investing $800 million in California on ZEV infrastructure, brand-neutral
Settlement Monetary Injunctive
2.0 Liter
Diesel $381 million (Trust)$800 million
3.0 Liter
Diesel
$42 million (Trust)
$25 million (APCF1)
New ZEV
Models/Types
Unfair and
Deceptive
Acts (UDAP)
$86 million (AG’s office)2
Penalty/Civil $154 million (APCF1)
Total State to Manage
$688 million
Electrify America
to Manage
$800 million
VW Settlement
Commitments in California
1 Air Pollution Control Fund
2 $76M for legal fees, $10M to be distributed at the attorney general’s discretion to
state and local agencies as research grants
4 Supplement to the California ZEV Investment Plan
public awareness marketing, increasing access to ZEVs, and green city projects. So if done well,
this investment will benefit Volkswagen in their new ventures into the ZEV world without a
doubt. But it will also benefit equally, if not more so just based on numbers, the other firms and
stakeholders that are involved in ZEV as well [CARB Hearing].
Similarly, the head of EPA’s Enforcement Office testified before the U.S. House of Representatives that
“In this case, this is a part of the injunctive relief; this is not a penalty…. It's an investment that VW is
making in ZEV infrastructure” [Giles]. All parties understood that this investment would have to be
guided by business needs, in order to increase the
likelihood that Electrify America is able to create a
sustainable network that provides services to
Californians for longer than the ten years covered by
the Consent Decree.
Appendix C requires that infrastructure investments
“should support and advance the use of ZEVs in the
United States by addressing an existing need or
supporting a reasonably anticipated need.” (1.10.1)
Electrify America will be investing in disadvantaged,
low-income, and underserved communities because we
believe these investments are economically justified and meet an existing need, as well as being
consistent with California priorities.
After California, the United States and Volkswagen reached agreement upon the terms of and signed the
2.0 Liter Consent Decree establishing the ZEV Investment Commitment, California’s legislature passed
legislation (AB 1550) requiring a portion of its own cap and trade dollars to be spent specifically within
certain census tracts that the state has labelled “disadvantaged” and “low-income.” Some commenters
incorrectly believe that this requirement applies to Electrify America’s investments presented in the
Cycle 1 ZEV Investment Plan. However, the California Office of Legislative Counsel interprets that this
requirement is applicable to State of California allocation of funds raised through cap and trade
auctions. The requirement does not apply to all state spending, such as the California Energy
Commission’s spending on ZEV infrastructure authorized through 2024 under AB 8. This requirement
also does not apply to private business investments in vehicle fueling infrastructure, whether the
investment is in gasoline stations and CNG stations distributing a fuel regulated under cap and trade, or
hydrogen stations and electric vehicle charging stations supporting ZEV technology use.1
1 Under SB 350, California’s investor-owned utilities were authorized to build charging equipment and pass that
cost on to customers through their rate base, subject to PUC approval. In rate cases before the PUC, the utilities
agreed to build 10-15 percent of stations specifically in census tracts that the state has designated as
“disadvantaged,” to study utilization in these areas, and to study barriers to further adoption of ZEVs. But this
condition is not a statutory requirement.
--Cynthia Giles,
EPA Assistant Administrator
in a hearing before the
US House of Representatives`
In this case, this is a part of the
injunctive relief; this is not a
penalty…it's an investment that
VW is making in ZEV
infrastructure
5 Supplement to the California ZEV Investment Plan
3 10-Year Vision
Electrify America LLC, headquartered in Virginia, is a wholly-owned subsidiary of Volkswagen Group of
America (VWGoA) created to fulfill VWGoA’s ZEV Investment Commitment. Electrify America is
investing $800 million over the next 10 years in zero emission vehicle (ZEV) infrastructure, education,
and access (including the Green City Initiative) to support the increased use of ZEV technology in
California, representing the largest commitment of its kind to date. Based on figures from the Council of
Economic Advisors and U.S. Department of Transportation related to highway and transit investments,
the $800 million being spent is estimated to support up to 8,500 jobs over the 10 year course of the
investment [Dept. of Transportation, Council of Economic Advisors].2
Electrify America’s vision is to establish a premier ZEV charging network that is comprehensive,
technologically advanced and customer-centric -- to drive ZEV adoption by reducing charging anxiety
and increasing convenience, which clearly benefits Californians using ZEVs as a primary vehicle. We will
build a nationwide network of workplace, community, and reliable highway chargers that are easy to
find and use. Our infrastructure investment, combined with our education and access programs, will
enable millions of Americans to discover the benefits of ZEV driving.
As laid out in both the Cycle 1 CA ZEV Investment
Plan and the EPA-approved Cycle 1 National ZEV
Investment Plan, one of Electrify America’s
guiding principles is to build a long term,
economically-sustainable network that provides
services beyond the 10 year consent decree
window. The first cycle of investment will focus
on establishing the largest nationwide network of
non-proprietary charging infrastructure,
deploying high power charging stations capable
of refueling a ZEV at 10-20 miles of range per
minute. The stations will be compatible with EVs
from all major brands, not just those produced
by Volkswagen Group brands. Instead, the goal is
to promote universal access to the extent
possible. In particular, multiple technologies (L2,
DCFC) and multiple non‐proprietary connectors and charging protocols (e.g., CHAdeMO, CCS) will be
offered to maximize public access to Electrify America’s charging infrastructure.
These stations will be designed to be interoperable with other charging networks, pending agreements
with other charging providers. They will be deployed in metro areas and along high traffic corridors
where ZEV charging infrastructure is projected to be most in demand, utilizing an analysis-based
2 The Council of Economic Advisors estimates that every $1 billion in federal highway and transit investment would
support 13,000 jobs. This total count includes direct, indirect, and induced jobs. The estimate here is for the
number of jobs created by infrastructure and Green City investments, and it does not include jobs created through
brand-neutral education and awareness or Electrify America overhead. The estimate assumes that infrastructure
and Green City investments will continue to be the same percentage of total spend t hat they are in Cycle 1, and
that ZEV investments create a similar number of job-hours per dollar spent as highway and transit investments.
Overview of Cycle 1 California Plan
Community
charging (L2,
50-150Kw)
workplaces,
depots, etc.
Highway fast
charging (150-
350Kw)
~$75M
Public educ.
& aware-
ness
~$20M ZEV access
initiatives
“Green City”
~$44M
~$45M
6 Supplement to the California ZEV Investment Plan
approach as strongly recommended by Federal experts [Friedman]. Electrify America envisions its
access, education, and Green City investments to expose Californians from all walks of life to the
benefits and utility of ZEV technology, resulting in widespread growth and depth of awareness and
interest in ZEV technology among the general public.
Electrify America strives to be an analysis driven company that utilizes data to guide investment to
maximize impact, learns from past failures in the ZEV refueling industry, listens to experts (e.g. UCLA,
UC Davis, National Renewable Energy Laboratory, and the National Academy of Sciences), and future-
proofs its investments whenever possible.
As Electrify America acknowledged at the March 24, 2017 CARB hearing, the timeline for developing the
Cycle 1 California ZEV Investment Plan established by Appendix C is very short. Electrify America
solicited and considered more than 500 suggestions, proposals, and guidance submissions for its Cycle 1
ZEV Investment Plans, including some from environmental justice organizations, and it has already
responded to most submissions. These recommendations, suggestions, and proposals significantly
impacted the Cycle 1 ZEV Investment Plans. However, the short timeline limited Electrify America’s
capacity to engage with stakeholders and produced some confusion about both Electrify America’s
intentions and the underlying nature of the ZEV Investment Commitment. Electrify America plans to
engage in an even more robust outreach effort in future planning cycles.
Electrify America has strategically and consciously not begun planning for future investment cycles, as
the company believes that each investment cycle offers the opportunity to consider new information,
revisit past assumptions, and consider feedback. Electrify America will update its analytical models,
engage in a robust National Outreach strategy, monitor new technology and public policy developments,
track evolving consumer expectations, and fully explore the merit of the full set of allowable ZEV
Investments during the planning and development of each future ZEV Investment Plan.
Conceptually, Electrify America envisions that it will use an analysis driven process to identify
investments in Cycles 2-4, and likely investments could include adding new routes to expand the
breadth of the ZEV highway charging network, reducing spacing between stations, increasing the
charging density within existing metro areas, focusing investment in additional metro areas, expanding
education programming, and deploying successful access programs in a second Green City. Electrify
America notes that it was not able to select every metropolitan area that submitted a strong proposal,
but it will likely expand its community charging investments into metro areas with supportive
government policies and strong utility integration.
Electrify America’s goal of an economically sustainable charging network will be easier to realize if the
ZEV consumer market expands. According to the National Academy of Sciences and UCLA’s Luskin
Center for Innovation, current ZEV consumers are predominantly well-educated males, the majority of
whom purchase a ZEV as a secondary vehicle (see Figure 1.) Regardless of infrastructure, ZEV cost of
ownership is and will continue to be a barrier to adoption for low-income consumers, as more than 95%
of ZEV vehicle models projected to be on the market between now and 2021 are projected to sell for
$30,000 or more.
These demographic realities are issues that Electrify America will work to address through its brand-
neutral education and awareness efforts, and active engagement with auto dealers and local
stakeholders, including the environmental justice community, provides an important opportunity to
7 Supplement to the California ZEV Investment Plan
address this challenge. Electrify America is committed to collaborating with and obtaining input from
environmental justice, equity, and other community-based groups serving low-income residents to help
inform future investment cycles, as part of the Outreach process. Electrify America will welcome
meaningful input from all stakeholders on where ZEV investments are most needed and will be most
utilized.
Figure 1: Demographics of ZEV Buyers in the United States
Electrify America will strive to address the needs of the market, and it will support advanced new ZEV
technologies to the extent practicable for vehicle adoption. Our hope would be that at the end of the
ten year period, not only has the $800 million investment in California been successfully deployed, but
Electrify America is also acknowledged to be a change agent for infrastructure development in general –
from its scientific and collaborative approach to its highly utilized and impactful investments. We would
also like to be known as a unique company that has not only quickened the pace of securing California’s
goal toward emission free driving, but has encouraged and guided others to invest appropriately as well.
$200-299k
67%$300k+
$150-199k
$50-74k
$100-149k
$25-49k 11%
33%
32%
$75-99k
17%
59%
41%
Likelihood to purchase BEV by
household income, %
ZEV use as primary or secondary
vehicle by ZEV owners1, %
68%
Primary
vehicle
32%
Secondary
vehicle
Percent of vehicle buyers who are
college graduates1, %
86%
59%ICE
BEV
Percent of vehicle buyers who are
male1, %
ICE
77%
60%
BEV
1 US consumers only
SOURCE: National Academy of Sciences, UCLA Luskin Center, RECS 2015, Experian, HIS, McKinsey Sustainable Mobility
Initiative: 2016 Electrified Vehicle Consumer Surveys
8 Supplement to the California ZEV Investment Plan
3.1 Differences between the Cycle 1 National and California ZEV Investment Plans
Electrify America has one vision, presented in both the EPA-approved Cycle 1 National ZEV Investment
Plan and the pending Cycle 1 California ZEV Investment Plan. The plans were developed using similar
methodologies and analysis. But to implement that vision, the two plans differ in a few notable ways.
First, the Cycle 1 CA ZEV Investment Plan proposes a substantial investment in providing ZEV access for
those who do not own ZEVs, or cannot afford to own ZEVs, and therefore represent a key underserved
population. The $44 million Green City Initiative is California-specific, while the brand-neutral Education
and Awareness programs in California will include access programs, such as ride and drives. These
access efforts are not currently a focus of Electrify America investment outside California.
Second, consistent with California stakeholder comments and feedback emphasizing the importance of
community charging, the Cycle 1 CA ZEV Investment Plan proposes to build nearly 90 percent of its
charging stations at the community-level, including at multi-unit dwellings, workplaces, retail
establishments and public parking lots in California. This represents a larger proportional investment at
the community level than Electrify America plans to make in metro areas outside of California. Electrify
America’s community charging proposal for California has a larger budget ($45 million) than community
charging at the national level ($40 million), and it is to be spent in approximately half as many metro
areas. When combined with Green City Initiative investments, $89 million will be spent at the
community level in California during Cycle 1.
9 Supplement to the California ZEV Investment Plan
4 Additional Information on the Cycle 1 California ZEV Investment Plan
In its February 17th guidance letter to Electrify America, CARB “urged” Electrify America to prioritize
investment in “disadvantaged, low-income, underserved, and disproportionately impacted
communities.” Appendix C did not include a goal of benefiting any specific community or type of
community. However, at the March 24th hearing, Electrify America agreed to study how the investments
proposed in the Cycle 1 ZEV Investment Plan impacted the communities prioritized by CARB in its
February letter.
Electrify America notes that CARB prioritized “underserved” communities in its guidance, and that
Appendix C requires the ZEV Investment Plan to describe how some, but not all, of the investments will
“increase access in underserved areas” (3.3.2.1).3 Throughout this document, Electrify America has used
the definitions of disadvantaged and low-income communities, and census tract designations, published
by CARB this year [CARB 2017].
After considerable study and review, Electrify America concludes that the analysis-driven and
economically-justified business investments laid out in its Cycle 1 CA ZEV Investment Plan represent a
potentially substantial benefit to underserved, disadvantaged, and low-income communities urged by
CARB for prioritization. We appreciate the opportunity to explain how.
4.1 A High-speed Highway Network
A statewide, $75 million network of fast charging stations will serve all of California’s ZEV drivers, but it
is especially important to those who want or need their ZEV to serve as a primary vehicle that meets all
transportation needs.
The California highway network was designed to place high-speed charging stations along the long-
distance routes which are anticipated to be most underserved and which link prioritized metro areas, in
order to form a cohesive statewide network. At a high level, ZEV traffic was estimated along every major
route in California, and, after taking into account existing charging infrastructure supply along those
routes, the estimated ‘supply-demand gap’ for charging stations along each route was calculated. This
allowed Electrify America to identify which routes were most underserved and in greatest need for new
infrastructure investment.
In addition to serving the most underserved routes, a network of super-fast charging ZEV stations will
increase the utility of ZEVs, allowing low and moderate income Californians to choose a ZEV as their one
and only vehicle. Extensive research by UCLA shows that “highly-educated, high-income households
working in management have a higher propensity to purchase BEVs” today, and that 68 percent of
consumers purchase a ZEV as a secondary vehicle. These trends are seen even with regard to lower cost
ZEVs, in part because lower and moderate income Californians require that their one vehicle meet all of
their needs [NAS, Sheldon-UCLA]. As a result of the Electrify America network of fast charging stations,
low and moderate income Californians will be able to drive ZEVs to all areas of the state with fewer
3 “Underserved” is not defined in Appendix C. Electrify America has used the Oxford English Dictionary definition:
“inadequately provided with a service or facility.”
10 Supplement to the California ZEV Investment Plan
range restrictions from a lack of infrastructure, stopping at stations that can potentially add up to 20
miles of driving range per minute of charging. They will be able to reach Mono Lake or Joshua Tree for
the weekend, or visit family across the whole state, from Imperial Valley to Eureka, or from San Diego to
Lake Tahoe.
Thus, the full highway network will be to the benefit of ZEV drivers who live in disadvantaged or low-
income communities. In addition, our initial analysis shows that more than 50 percent of these stations
will be in a census tract that CARB designated in 2017 as disadvantaged or low-income [CARB]. Many of
these highway station sites may move slightly within the same geographic area during the site validation
and acquisition phase as a result of cost, convenience, utility service, or other considerations, but the
initial target sites indicate that the highway network will likely represent a very substantial investment in
communities prioritized by CARB.
4.2 Building a Green City for ZEV Access
The $44 million Green City Initiative will be
launched in Sacramento, pending approval of
the Cycle 1 CA ZEV Investment Plan. It will
provide access to ZEVs to those who do not
own ZEVs, or cannot afford to own ZEVs, and
therefore represent a key underserved
population. Sacramento has already initiated a
car sharing service that serves low-income
communities as a result of a CARB grant, and
Electrify America intends to build on that work.
University of California research shows that
“carsharing programs that feature PHVs and
EVs are providing access to those who would
otherwise not have access to such vehicles,”
and “in light of current model availability and
EV costs, these programs provide exposure to a
demographic that otherwise has a lower
propensity to own such vehicles. The result of this access is an improved impression of ZEVs and a
stronger affinity toward ZEV technology” [Shaheen]. All of this investment will be available to and
increase ZEV access for residents of disadvantaged, underserved, and low-income communities
prioritized in the CARB guidance.
A Green City Initiative in the City of Sacramento will result in considerable investment in CARB priority
communities. Sacramento Mayor Darrell Steinberg noted in a letter to CARB that Sacramento is “one of
the most racially, ethnically, and culturally diverse cities in the nation” and that “a disproportionate
share of Sacramento’s residents live in disadvantaged communities” [Steinberg]. The specific locations
of Green City investments will be spread across Sacramento and will likely move on a daily basis. But
Electrify America’s geospatial analysis, presented in the map above, shows that approximately 59
Disadvantaged and Low-income Census Tracts in
the City of Sacramento
59% of
Sacramento area
is disadvantaged
or low-income
11 Supplement to the California ZEV Investment Plan
percent of the Sacramento census tracts in the target geography for Green City Initiative investments
are designated as disadvantaged or low-income by California.
4.3 Community Charging
The National Academy of Sciences’ 2015 comprehensive report on overcoming barriers to ZEV
deployment endorsed a strategy focused on specific geographies or “beachheads,” stating that a strong
strategy to increase ZEV adoption “logically would focus on key geographic regions or regional corridors
where momentum has already been established; infrastructure is more readily available; [and] word-of-
mouth between neighbors, friends, and co-workers can occur more readily” [NAS, 2015]. Through the
National Outreach Plan process, Electrify America received approximately 50 proposals from cities for
concentrated ZEV infrastructure investments in specific metropolitan areas, and many additional
recommendations from states (e.g. Virginia), local governments and other stakeholders expressing
support for concentrating investment in metropolitan areas.
Under the consent decree, Electrify America is required in the ZEV Investment Plan to describe how
some of its investments will “increase access in underserved areas.” The Cycle 1 CA ZEV Investment
Plan originally proposed to concentrate a $45 million Metro Area Investment in five “beachhead”
metros. We are proposing to expand this to a sixth metro area in this Supplement.
To select these metro areas, Electrify America conducted an analysis to determine which communities
would likely be most underserved through 2020. Specifically, Electrify America analyzed ZEV sales
projections from Navigant Research and infrastructure data from the National Renewable Energy
Laboratory (NREL) to project the amount of infrastructure investment needed in each major
metropolitan area. By establishing the anticipated gap between demand for charging infrastructure and
the current supply of charging capacity, Electrify America was able to identify the communities
projected to be in most need of additional charging services. Electrify America’s Cycle 1 CA ZEV
Investment Plan directs investment at the most underserved metro areas as determined by this analysis,
and therefore we believe that all of the metro investments will be consistent with Appendix C and the
prioritization guidance provided by CARB.
12 Supplement to the California ZEV Investment Plan
Using this methodology, five underserved California metros were identified: (1) Los Angeles-Long Beach-
Anaheim, (2) Sacramento-Roseville-Arden Arcade, (3) San Diego-Carlsbad-San Marcos, (4) San Francisco-
Oakland-Hayward, and (5) San Jose-Sunnyvale-
Santa Clara.
Based on new information provided through the
public comment process and ongoing
refinement of the gap analysis, Electrify America
intends to add the Fresno metro area as a new
target for community charging in Cycle 1.
Analysis of Fresno’s inclusion is ongoing, so this
section presents the beachhead communities as
originally proposed in the Cycle 1 CA ZEV
Investment Plan. Electrify America notes that
other metro areas will be considered for
investment in future cycles, and Electrify
America will continue to refine its methodology
as the industry develops.
Within each metro area, the Cycle 1 CA ZEV
Investment Plan proposes to focus investment
across five use cases: workplaces, multi-unit
dwellings, retail, charging depots, and municipal
lots and garages. These were selected in part
based on the degree to which they meet an underserved need.
For example, Electrify America has identified residents of multi-unit dwellings (MUD) as a seriously
underserved population. About 25 percent of U.S. households live in multifamily residential complexes.
But according to the National Academy of Sciences, “Although 61 percent of single-family houses had
access to charging, only 27 percent of multifamily dwellings had parking spaces with access to
charging…. Multifamily residential complexes can face many challenges in installing PEV charging
equipment; some are similar to a typical commercial building, and others are unique to multifamily
dwellings” [NAS, 2015]. Similarly, a report by the UCLA Luskin Center for the California Energy
Commission on the barriers to plug-in vehicle adoption in the South Bay area of Los Angeles concluded
that “the MUD barrier is likely serving as a significant constraint to PEV adoption” due to high
installation costs. The report recommends substantially greater investment in MUD charging
equipment, especially grouped to increase cost effectiveness, which is Electrify America’s intention
[Turek].
In addition, UCLA researchers found that the creation of charging depots (a second metro use case
proposed in the Cycle 1 CA ZEV Investment Plan) in neighborhoods where the MUD inventory is too old,
upgrades are too costly, or where building owners are unwilling to invest, is another important strategy
to meet the underserved residents of MUDs. The researchers write that a “strategy of building or
encouraging EVSE development in proximity to clusters of MUD properties may prove successful to the
continued development of the EV market” [Turek].
Metropolitan Areas Prioritized for Community
Charging Investment
1
Sacramento-Roseville-Arden Arcade
San Francisco-Oakland-Hayward
San Jose-Sunnyvale-Santa Clara
Fresno
Los Angeles-Long Beach-Anaheim
San Diego-Carlsbad-San Marcos
13 Supplement to the California ZEV Investment Plan
Within each selected metro area, Electrify America is engaging in a rigorous, analytical process
consistent with the Department of Energy’s guiding principle that infrastructure investments should be
analysis-driven and focused on investment that will most substantially increase ZEV deployment
[Friedman]. Electrify America is using analytics to identify census tracts for each use case where new
charging stations are most likely to support ZEV deployment, using the indicators identified by the
California Center for Sustainable Energy as correlated with areas of high ZEV sales, combined with the
density of those use cases or the incidence of likely usage of that charging destination from nearby ZEV
sales areas. For example, areas with a high density of workplaces and a high daytime population will be
prioritized for the workplace charging investment.
Through this process, Electrify America has prioritized 1,500+ census tracts for community charging
investments, and more than 35 percent of these census tracts are identified by CARB as
disadvantaged or low-income communities. Electrify America has budgeted to construct community
level charging stations at approximately 350 sites in the Cycle 1 California ZEV Investment Plan, so
Electrify America does not have the budget to invest in all 1,500+ census tracts prioritized for stations in
Cycle 1. Electrify America notes that it will likely endeavor to continue investment in prioritized census
tracts during future investment cycles, if the analysis continues to support investment in such areas.
Furthermore, Electrify America continues to refine and add new data to its model based on internal and
external feedback, as well as updated forecasts.
To identify the 350 sites, prioritized census tracts will serve as guidance to suppliers and in-house site
acquisition teams for “boots-on-the-ground” and more qualitative follow-up due diligence. This process
is on hold pending approval of the Cycle 1 CA ZEV Investment Plan, so Electrify America does not know
which prioritized census tracts will host stations at this time. Wherever possible, Electrify America will
also work with local stakeholders and utilities to further identify site opportunities and accelerate
installation in favorable areas.
The bottom line is that Electrify America’s metro investment will be made in what objective analysis
found to be the most underserved metro areas of California, and the use case investments will serve
underserved populations within those communities. Furthermore, while no station sites have been
selected to date, Electrify America’s analysis-driven process to identify census tracts for targeted
investment include a significant percentage of census tracts identified by CARB as disadvantaged or low-
income communities.
4.4 Brand-Neutral Public Education and Outreach Activities
Electrify America plans to invest approximately $20 million in the first cycle in education and outreach
programs in California. As shown in Figure 2, recent survey data showed that only 48 percent of vehicle
buyers in California have heard of ZEVs, which is only slightly higher than the 41 percent of comparable
consumers nationwide, despite the vast number of initiatives in California to promote ZEV technology.
The investment during the first 12 months, as we note in the Cycle 1 CA ZEV Investment Plan, will focus
on broadly educating the public on the fun to drive, utility and other benefits of driving ZEVs through
mass, digital, and experiential marketing. This is intended to be a broad awareness and education effort
targeted at all consumers, including those who live in disadvantaged, low-income or underserved areas.
14 Supplement to the California ZEV Investment Plan
Figure 2: The ZEV Consumer Journey in California
In months 13-22, we will explore more targeted awareness initiatives, as well as potential education
partnerships. We received nearly 150 comments and proposals through the National Outreach Plan
process on education and outreach, which made clear the extensive need for ongoing ZEV Education
and Outreach efforts. Electrify America intends its investment to leverage and reinforce these ongoing
efforts. We have already begun conversations with a number of potential partners on educational
initiatives, including Plug-in America, the Electrification Coalition, MDR (a Dunn and Bradstreet Company
focusing on school education curriculum), and a coalition of automotive companies and states. In
partnership with other groups, Electrify America will also develop materials on the benefits of ZEVs,
conduct ride-and-drive events, and further build public awareness of ZEVs through proven awareness
strategies.
These efforts will be deployed across the state – not just in metro areas targeted for infrastructure
investment – and they will include activities in areas that the state classifies as disadvantaged or low-
income. They will also be in a language other than English where appropriate.
4.5 ZEV Access Initiatives
Numerous governments and other stakeholders proposed ZEV access programs in their comments to
Electrify America, which are currently under review. Experiential initiatives like ride-and-drive events are
being considered to help increase ZEV access and exposure for as many Californians as possible,
SOURCE: Strategic Vision NVES 2016
Penetration across the ZEV consumer journey, % of consumers Focus of EA
awareness
program
Funnel step“I have heard
of [a ZEV]”
Consider PurchaseTest-
drive
“I have
researched the
technology”
“I have driven
one”% through-put48%
34%
16%
3.9%
New car-
buyers
Aware-
ness
“I am purchasing
a new car”
71%
47%
24%
Throughput
from
previous
stage
“I currently own
one”
100%
15 Supplement to the California ZEV Investment Plan
including in underserved, disadvantaged, and low-income areas. Electrify America plans to fund these
investments from budgets currently allocated to education and outreach activities. According to the U.S.
Department of Energy, experiential learning activities are one of the most effective ways to drive ZEV
adoption because they allow consumers to discover that ZEVs are fun to drive and have other benefits
relative to cars with internal combustion engines [DOE Workplace Charging Challenge]. The purpose of
these activities is to increase the public’s awareness of and access to ZEVs and allow them to experience
ZEVs without having to purchase a vehicle.
4.6 Commitment to Workforce Development and Supplier Diversity
Electrify America plans to hire an initial workforce of just over 70 employees, with most personnel
focused on real estate procurement, operations, and hardware/network, which are the critical functions
for charging infrastructure deployment. This team intends to leverage outside vendors, including real
estate firms, EVSE installers, equipment and construction suppliers, site host partners, advertising
agencies, and car sharing service providers in order to cost-efficiently complete Electrify America’s
investments at an unprecedented scale and speed. Most of these suppliers will be U.S.-based firms. As
such, Electrify America’s $250M investment in infrastructure implementation and maintenance across
the nation, and the additional $120M investment in California, is expected to create significant
opportunity for the existing American charging industry and employment in many American
communities.
Electrify America is committed to ensuring that investment under its ZEV Investment Commitment
reflects the rich and diverse characteristics of California and its people. To meet this commitment,
Electrify America staff plans to conduct outreach efforts and activities to: ensure potential new
suppliers and contractors are aware of RFP opportunities resulting from the ZEV Investment
Commitment; to encourage greater participation by underrepresented groups including certified
veteran-, women-, and minority-owned businesses; and to assist applicants in understanding how to
participate in the RPF process.
As an initial step, bidders to Electrify America’s construction RFP are being asked to include information
regarding certified minority-, women-, and veteran-owned business enterprise participation in base bids
and options. Electrify America plans to request that contractors report on participation while under
contract, and Electrify America will share this information with CARB as appropriate.
4.7 Summary of Investments Consistent with CARB Priorities
Electrify America has looked carefully at how the investments proposed in the Cycle 1 CA ZEV
Investment Plan will impact the disadvantaged, low-income, and underserved communities identified as
priorities in CARB’s February 17 guidance.
As explained in this section, Electrify America anticipates (but does not guarantee) that more than 35
percent of the ZEV Investments proposed in the Cycle 1 CA ZEV Investment Plan will be in census tracts
16 Supplement to the California ZEV Investment Plan
that CARB specified as low-income or disadvantaged in April 2017. Electrify America anticipates that
significant investment in these low-income and disadvantaged communities will occur across all four
major investment categories, which include the High-speed Highway Charging Network, Community
Charging, the Green City Initiative, and Education and Awareness programs.
Electrify America also anticipates that substantial Cycle 1 investment will be in or will serve
“underserved areas” explicitly referenced in Appendix C and CARB’s guidance.
Electrify America must highlight that each potential secured station site requires consideration of at
least five other locations in the same vicinity based on real estate validation and contract realities typical
of charging infrastructure deployment. Therefore, we will need to evaluate multiple sites concurrently,
often across multiple census tracts, which helps explain why Electrify America has only identified priority
census tracts for metro station investments at this time. Site selection is paused until such time that an
approved plan by CARB will enable specific site host discussions and contracts. It should be noted that
the site validation and acquisition phase may dictate that sites move as a result of cost, permitting,
utility service, or other considerations.
17 Supplement to the California ZEV Investment Plan
5 Additional Steps to Support Disadvantaged, Low-income, and
Underserved Communities
Electrify America has listened closely to the requests and suggestions of California stakeholders
throughout multiple comment periods, and we believe that the explanation in Section 4 will address
most of their concerns with regard to underserved, disadvantaged, and low-income communities.
Electrify America believes that investments proposed in the Cycle 1 CA ZEV Investment Plan would be
consistent with the requirements of Appendix C, and would be of substantial benefit to the communities
prioritized by CARB for investment in its February guidance letter.
To further accommodate the suggestions and requests and further demonstrate its common
commitment to California’s priorities and values, Electrify America supplements its Cycle 1 CA ZEV
Investment Plan in the following ways.
5.1 Expanding Community Charging to Include the Fresno Metro Area
Electrify America intends to add the Fresno metro
area as a sixth beachhead for community
charging investment. Electrify America’s analysis,
described in Section 4, did not project that Fresno
would be one of the five most underserved metro
areas of California in 2020 in terms of ZEV
infrastructure. However, new data included in
the San Joaquin Valley Electric Vehicle
Partnership’s letter to CARB shows growth in ZEV
deployment within the Central Valley, suggesting
that the Fresno area may be a more rapidly
emerging ZEV market than previous analysis has
shown [Williams]. Electrify America plans to
reallocate resources from within the existing
Cycle 1 Community Charging budget to accommodate the addition of the Fresno metro area.
5.2 Focus Education in CARB-prioritized Communities
CARB’s recent report, Overcoming Barriers to Clean Transportation Access for Low-Income Residents,
recommends “funding to expand clean transportation and mobility option education and outreach
efforts and opportunities in low-income and disadvantaged communities to increase awareness.” In
response to this recommendation, Electrify America intends to modify its Cycle 1 Brand-neutral
Education and Awareness spending plan to commit $2-3 million – a very substantial portion of its
education partnerships budget -- to seek partnerships with entities with particular access and credibility
within California’s disadvantaged and low-income communities. Electrify America will explore through
60 182
513
1140
1318
1741
2011 2012 2013 2014 2015 2016
San Joaquin Valley EV Market
Number of CVRP Rebates
SOURCE: San Joaquin Valley EV Partnership CARB Comment
18 Supplement to the California ZEV Investment Plan
these partnerships a culturally appropriate awareness campaign (in a language other than English where
appropriate) which could incorporate the activities recommended by CARB’s report, including providing
educational curricula for kindergarten through 12th grade students, increasing knowledge of ridesharing
(including carpooling) and car sharing options that utilize zero-emission vehicles, and conducting ride
and drive and other access activities.
Electrify America will also explore, through these partnerships, communicating the economic appeal of
adopting ZEV technology in low-income California communities as a result of current ZEV incentives. As
a result of new incentives, the ZEV mandate, and Federal tax incentives, a ZEV is in some cases the most
affordable new car available for low and moderate income consumers in California [Auto Alliance].4
However, CARB data shows that more than a fifth of ZEV buyers in California fail to claim the state
rebates to which they are entitled due to lack of awareness and auto dealer assistance, and interest in
owning a ZEV is concentrated in upper income brackets as shown in Figure 1 [Williams 2015]. The gap
between the perceived and actual affordability of ZEVs appears to be considerable, and it presents a
very meaningful opportunity for an effective, targeted education effort.
5.3 Increasing Access to a High Speed Highway Charging Network
Electrify America’s high speed charging network is designed to provide statewide fast refueling for ZEVs,
substantially increasing the utility of ZEVs used as primary vehicles. All Californians who drive a ZEV will
be able to benefit from this network, refueling their vehicles whenever necessary using any one of
numerous easy payment options, including credit cards. However, Electrify America plans to take the
following additional steps to increase access to the highway network for those from low-income and
disadvantaged communities.
Improve Access for Used Cars: Electrify America has approached several vehicle manufacturers to
explore partnerships through which the vehicle manufactures would provide access to Electrify
America’s charging network as part of the cost of purchasing or leasing a new ZEV. But Electrify America
plans to study whether such a partnership could extend to the purchase or lease of pre-owned ZEVs, as
we are aware that moderate and low-income Californians are more likely to purchase or lease pre-
owned vehicles. Such a partnership could be established with either vehicle manufactures, who
frequently sell ZEVs after they come off leases, or with large independent retailers of pre-owned
vehicles. Electrify America is committed to exploring this as a means to increase ZEV infrastructure
access for moderate and low-income Californians.
Complement California Programs: To complement California ZEV programs, such as CARB’s programs
under the Charge Ahead California Initiative authorized in SB 1275 (de León) and the Initiative’s program
to help moderate and low-income Californians to scrap their old vehicle and replace it with a ZEV,
4 According to Auto Alliance analysis, in February 2017, low-income Californians could lease multiple models of
BEV at no or even negative net cost. Specifically, the Alliance found that the total cos t of three year leases
advertised in California for five models of BEV, including monthly and down payments, was nearly the same as
California’s incentive for low-income residents to lease a ZEV. For low-income residents of the San Joaquin Valley,
where an additional incentive is available, the Alliance concluded that low-income residents would actually make
more than $1,000 by signing an advertised three year lease of any of five BEV models [Auto Alliance].
19 Supplement to the California ZEV Investment Plan
Electrify America will work with CARB and other stakeholders to study ways to facilitate easy access to
its ZEV Investments among program participants.
5.4 Participating in Efforts to Identify Market Barriers
Barriers to entry for low and moderate income Californians are not well understood. Investor-owned
utilities have begun a process to study these barriers and offer solutions, while CARB has separately
published a draft report, titled Overcoming Barriers to Clean Transportation Access for Low-Income
Residents, on this topic on which it is soliciting feedback. Additional ideas, insight, and research are still
required. Electrify America is committed to being an active participant in the ongoing efforts within
California to identify market barriers and advise California on public policy solutions.
20 Supplement to the California ZEV Investment Plan
6 Planning, Transparency, and Coordination
6.1 Partnerships
Throughout its development of the Cycle 1 CA ZEV Investment Plan, Electrify America consulted
knowledgeable experts in the ZEV field with extensive automobile manufacturing, utility, infrastructure,
policy, communications, technology, and consumer advocacy backgrounds.
Electrify America met with both the U.S. Department of Transportation and the U.S. Department of
Energy, who provided detailed information on the Federal government’s Smart City effort, their process
for designating EV charging corridors along highways under the FAST Act, lessons learned from the EV
Project and the Workplace Charging Challenge, and ongoing work to support deployment of non-
proprietary DC fast charging at power levels up to 350 kW. Additionally, most vehicle manufacturers
were consulted, and we collected their feedback about a new, comprehensive charging network that
would best suit their future ZEV customers.
Electrify America has conducted robust and frequent discussions with California organizations and
stakeholders in the charging infrastructure ecosystem including government, utility and other
organizations. These discussions were set up to not only to explain Electrify America’s objectives and
approach, but also to establish relationships for future dialogue aimed at helping Electrify America
improve its charging infrastructure planning and deployment (with an emphasis on speeding processes
such as permitting, easements, and other typical factors that slow down charging infrastructure
installations). These conversations also helped identify other charging infrastructure programs or
private/public funding opportunities that could be leveraged with Electrify America’s investments to
further increase the net funding in infrastructure. Example organizations we have had discussions with
(beginning in 2016) include: The California Energy Commission, California Public Utilities Commission,
California Go Biz, CalTrans, CalETC, NRDC, and the Greenlining Institute. Electrify America plans to
continue these discussions during the first and subsequent cycles to better ensure continuity and value
for our deployments in California. At the same time, Electrify America hopes to work with the California
entity responsible for managing the $423 million that the state may spend from the NOx Mitigation
Trust, once California designates the state agency that will serve as its beneficiary under Appendix D, to
avoid potential duplication or non-complementary infrastructure investments.
21 Supplement to the California ZEV Investment Plan
Figure 3: Electrify America Stakeholder Engagement
In the summer of 2016, Electrify America began engaging in conversations with California’s major
utilities, including Southern California Edison, Pacific Gas and Electric, San Diego Gas and Electric, L.A.
Department of Water and Power, and Sacramento Municipal Utility District. A key early goal of the
utility discussions was to better understand potential approaches for collaboration, co-investment, site
planning, speedier utility service and complementing existing utility-led workplace charging programs.
Electrify America discussed with investor-owned utilities their investments in Level 2 charging, which
were recently approved by the CPUC. The investor-owned utilities will invest primarily in the workplace
and multi-unit dwelling use cases, and they will not build DC fast charging stations. The dialogue
confirmed that Electrify America and investor-owned utilities plan to invest in different but
complementary workplace and MUD projects during Cycle 1, using a different selection methodology.
Going forward, we plan to continue these discussions and seek opportunities for cooperation, especially
as utilities explore investment in DC fast charging. As CARB staff noted at the March 24th hearing,
Electrify America’s charging infrastructure investment “is expected to satisfy less than 10 percent of
California's estimated demand based on the State's goal to have enough infrastructure in the state to
Organization
type No. of stakeholders and examples Nature of collaboration
California-based
Government
agencies
Received submissions from
ports, metros, and states, and
are responding to each entity
170+
Utilities
Discussed site proposals,
demand charges, and
operational integration
20+
Academia
Leveraged insights and
research findings on charging
use cases
12+
Associations 3+
Discussed partnership
models, site opportunities,
and best practices
Primary
regulatory
bodies
Discussed full investment
plan with iterative reviews and
feedback2
16+OEMs
Discussed potential
cooperation, future of ZEV
technology.
Charging
companies
Discussed partnerships and
interoperability5+
Interest
groups 10+Discussed best practices and
partnership models
Various OEMs
22 Supplement to the California ZEV Investment Plan
support 1 million ZEVs by 2020” [CARB Hearing]. Electrify America believes this demonstrates that
strong investments from other entities like utilities will be needed for the foreseeable future. Electrify
America hopes to help inspire, galvanize and guide these incremental investments on top of our own.
Electrify America has also had numerous conversations with Adopt-A-Charger, led by Kitty Adams, to
understand and potentially deploy Level 2 charging infrastructure in California state parks, which would
be consistent with goals set forth by the Governor’s office.
Finally, in terms of understanding existing charging infrastructure, Electrify America intends for its
investments to supplement other investments. Electrify America has been using data on existing
infrastructure from NREL, and we have now secured a license to use Recargo’s Plugshare “Data on
Demand” service to ensure we have nearly real time access to infrastructure as it is deployed. For near
future planned investments, Electrify America plans to secure this information from regular information
exchanges with the CEC and other government agencies to segregate charging infrastructure
investments for more complementary results.
6.2 Additional Information on Infrastructure Planning Processes
Electrify America developed a new
proprietary methodology to identify the
California metro areas expected to be most
underserved and in need of charging
infrastructure associated with forecasted EV
sales growth and fleet size by 2020 (see
Figure 4). This new approach, in simple
terms, derives the daily charging power
needs (expressed in megawatt hours/day)
for ZEV drivers outside their residence,
assuming that 78 percent of ZEV charging
needs will be met at home, as NREL research
shows. Outside the home could include
workplace, community charging in a variety
of shopping, restaurant and other parking
venues, as well as on highways. The
charging power gap used assumptions
including the battery size, charging power
and range efficiency (assumed 3.5 miles per
kWh) for the expected future fleet of new
EVs, including current EV units in operation.
We then consulted the DOE’s alternative
fuel database and Plugshare data to
understand current Level 1, Level 2 and
SOURCE: Navigant, 2016
<10,000 vehicles
10,000 –40,000 vehicles
40,000 –150,000 vehicles
>150,000 vehicles
Los
Angeles
Riverside
San Diego
Bakersfield
Visalia
Fresno
Santa
Maria Oxnard
San Luis
Obispo
Salinas
Merced
Modesto
Sacramento
Chico
Truckee
Eureka
Ukiah
Santa
Rosa
San
Jose
San
Francisco
Stockton
Vallejo
Napa
Santa Cruz
Figure 4: Projected Deployment of Electric Vehicles
in 2020
23 Supplement to the California ZEV Investment Plan
DCFC infrastructure available today to calculate the
power gap needed to solve the 22 percent of EV
driver charging needs that are expected to be met
outside the home.
Our methodology found -- in the six California
metros selected for Cycle 1 investment -- that
nearly 1,700 megawatt hours per day would be
needed to bridge the gap between charging
infrastructure in the ground today and what would
be needed by 2020 (see Figure 5). For reference,
one megawatt powers about 650 homes, so this
power gap is substantial to say the least. This
implies that considerable other private and public
investment in charging infrastructure will be
needed to reduce this charging power gap because
Electrify America is targeting to reduce the gap by
only four to eight percent by 2020 with its own
investments.
The gap analysis results will be a key factor in
determining the investment budget range per
metro area. In the case of California, Electrify
America intends to allocate its community charging
budget across metro areas in an attempt to reduce
four to eight percent of the gap in each metro
area. Electrify America has set a minimum budget for any metro area selected for community charging
investment in Cycle 1 nationally at $1 million -- an amount informed by infrastructure expert interviews
in the Fall of 2016 on the investment level necessary to create the “beachhead” effect. Electrify
America anticipates that all six of California’s community charging metro areas will receive investment
substantially above the minimum investment level in Cycle 1.
6.3 Additional Information on the Green Cities Selection Process
In order to determine the location of the initial Green City investments, Electrify America developed a
detailed and comprehensive evaluation methodology. A full description of this methodology has been
shared with CARB as confidential business information, but at a high level, Electrify America evaluated
California cities across three primary dimensions: city size, mobility fit, and potential for impact.
Electrify America selected city size, mobility fit, and potential for impact as the criteria with the
assumption that ZEV car sharing would be one of the primary initiatives developed over the first and
second 30-month investment cycles. They were intended to ensure that the Green City initiatives were
being developed 1) in a sizeable market where the initiatives could be scaled up over time, 2) in a
market where there was demand for car sharing initiatives, suitable commute patterns, and a gap
Figure 5: Supply-Demand Gap Analysis Results
281 103
36
807 231
186
364 150
Single-family home demand1
Projected 2020 supply-
demand gap,MWh/day
Metropolitan
area
San Francisco-
Oakland-
Hayward
San Jose-
Sunnyvale-
Santa Clara
San Diego-
Carlsbad-San
Marcos
Los Angeles-
Long Beach-
Anaheim
Sacramento-
Roseville-
Arden Arcade
71
Fresno
1694 668
70
Total
43
20
Public
24 Supplement to the California ZEV Investment Plan
between supply of existing car sharing fleets and potential demand, and 3) in a market which had a high
potential for impact, based on the potential of increasing ZEV access to disadvantaged and low-income
communities, the likelihood that the initiatives would be developed in an ecosystem supportive of ZEV
mobility, and the ability of the investments in that city to influence broader awareness in California,
nationally, and more broadly.
In analyzing California metro areas, city size selection criteria was first applied in order to develop a
shortlist of California cities. The shortlist was then scored across various sub-criteria (detailed below)
within the categories of mobility fit and potential impact and weighted based on relative impact of
each sub-criteria (see Figure 6). A brief description of these sub-criteria is provided as follows:
Mobility fit
Mobility demand: success factors for car sharing at a zip-code level based on commute lengths
and demographics, among other factors
Commute flow patterns: identification of connected centers of high transportation flows
within a metro area to allow for targeting of spend in areas where Green City services are most
likely to be utilized
Competitive situation: existing car sharing companies to determine extent of existing
competition
Potential for impact
Societal impact: presence of disadvantaged and low-income communities in each potential
metro area, as ZEV car sharing and other Green City initiatives could positively impact these
communities, particularly from an air quality perspective
Implementation feasibility: existing infrastructure and ZEV incentives supporting the
implementation and acceptance of ZEV mobility offerings
Awareness impact: relevance in influencing decision-making on mobility concepts and public
perception of ZEVs
25 Supplement to the California ZEV Investment Plan
Figure 6: Overview of Green City Selection Methodology
6.4 Response to Comments
As part of the National Outreach Plan required in Appendix C, Electrify America solicited proposals and
recommendations from outside parties to help substantiate and improve its Cycle 1 ZEV Investment
Plans. Electrify America notified stakeholders identified in Appendix C (i.e., states, municipal
governments, federally-recognized Tribes, and federal agencies) of the proposal submission and
comment period, which was initially opened from December 9, 2016 to January 14, 2017. Electrify
America allowed a 3-week grace period and considered submissions received through February 6, 2017,
when developing its Cycle 1 CA ZEV Investment Plan. A total of 484 submissions were received as of
February 6, 2017. Electrify America has also kept the comment page active, and it continues to receive
and review submissions relevant to plan implementation. In addition, CARB chose to hold two comment
periods on its own, and also collected comments on the Cycle 1 ZEV Investment Plan at a public hearing.
Electrify America has extensively considered the feedback from these processes when developing both
the Cycle 1 CA ZEV Investment Plan and this Supplement.
The submissions and comments provided Electrify America with information on the level of public
support for this plan’s investment strategies, and it also provided specific project ideas. A selection of
submissions includes the following:
Broad ZEV Industry Support: During comments in California, the Cycle 1 CA ZEV Investment plan
was strongly endorsed by almost every charging industry company, by the state’s largest utility
companies, and by the state’s largest automaker. Many of these commenters also emphasized
the enormous opportunity that this investment would create, and the urgency of rapid
approval.
1 Direct border with Los Angeles, thus counted as greater Los Angeles
City size filter
177 cities in scope >400k inhabitants
Cities in
California
Cities of medium
to large size
1
…Factor weight
33%Commute flow
patterns
2B
100%Implementation
feasibility
3B
100%Competitive
situation
2C
66%2A Mobility
demand
100%Societal impact3A
100%3C Awareness
impact
Overall
assessment
Weigh and combine score
Mobility fit
Potential for
impact
2
3
Los Angeles
(4,000k)
San Diego (1,300k)
San Jose (1,000k)
San Francisco
(900k)
Fresno (500k)
Sacramento (500k)
Long Beach
(500k)1
Oakland (400k)
Bakersfield (<400k)
….
Los Angeles
San Diego
San Jose
San Francisco
Fresno
Sacramento
Oakland
Each shortlisted city is scored via a defined logic
Assign score between 1 and 3
26 Supplement to the California ZEV Investment Plan
Charging Infrastructure Needs: The overwhelming majority of comments supported and, in
many cases prioritized, ZEV charging infrastructure deployment investments. This was true
across the full spectrum of commenters, from comprehensive proposals from state
governments to requests from small towns and ‘mom-and-pop’ stores for a single charger.
Commenters highlighted that charging infrastructure investments meet an identified need and a
recognized ZEV deployment barrier. Consistent with this feedback, Electrify America is
maximizing infrastructure investment in this plan in ways consistent with the requirements of
Appendix C.
DC Fast Charging along Highway Corridors: More than 100 comments and proposals focused
on the importance of and execution of a highway network, and nine states and numerous other
submissions explicitly urged Electrify America to prioritize investment in highway charging as its
highest investment priority. For example, the Sierra Club prioritized DC fast charging corridors,
explaining that they would have the effect of “reducing range anxiety, raising public awareness
of EVs, and spurring electric vehicle adoption outside of densely populated urban areas.”
Electrify America proposes to make its largest investment in this area, consistent with this
recommendation.
Community Charging: Comments from California-based entities expressed greater support for
community-level charging than we heard from national stakeholders. As noted in section 3.1,
this feedback validated the merit of greater community-level investment in California than
elsewhere in the nation.
Local Support for the Green City Initiative: Comments submitted to CARB demonstrated great
local interest in the Green City Initiative. Written submissions to CARB demonstrated that the
Sacramento Community has rallied behind the opportunity to host the Green City, which
validates Electrify America’s decision to select Sacramento as the first Green City, pending
approval of Cycle 1 CA ZEV Investment Plan. There was also tremendous support for the
selection of Los Angeles as a Green City expressed at the CARB hearing in Riverside. As a result,
in May, Electrify America executives met with the Los Angeles Mayor’s staff, local utilities, and
members of the Green City coalition in Los Angeles. Electrify America presented the substantial
level of community charging investment planned for the Los Angeles region, producing
productive dialogue and excitement about the potential for investment in the Los Angeles
region.
Support for Central Valley Investment: Many commenters in California advocated for ZEV
investments in California’s Central Valley. The Cycle 1 CA ZEV Investment Plan proposed
considerable investment along both the Interstate 5 and CA Highway 99 throughout the Valley,
but the data driven feedback received has prompted Electrify America to propose new
investment in Fresno, as detailed in Section 5.3.
Coordinated Planning with State and Regional Government: Many submissions, especially from
state agencies and regional coordinating entities like NESCAUM, emphasized the benefits of
coordinating infrastructure investments with ongoing state activities. For example, CalTrans
submitted a consolidated proposal to increase charging infrastructure through workplace
charging, park-and-ride transit hub charging, and charging along key interstate corridors. These
submissions have highlighted the value of coordinating with state agencies, and Electrify
America has already initiated coordination as part of its outreach effort.
27 Supplement to the California ZEV Investment Plan
Workplace Charging: Electrify America received more than 150 submissions supporting
investment in workplace charging, which is an additional validation of the importance of this use
case. Many Government submissions, such as the proposal from California’s Department of
General Services, proposed hundreds of workplace charging units at specific sites. Electrify
America will closely consider sites identified in each target metro area.
Multifamily Dwellings: More than 50 submissions proposed investment in the multifamily and
residential use case, affirming the importance of this use case.
Destination Charging: A small number of commenters suggested that Electrify America invest in
destination charging at hotels, parks, and other long dwell time locations. This use case will
receive more consideration from Electrify America given that some proposals had this focus,
including some compelling programs like Adopt-a-Charger.
Airports: The Federal Aviation Administration and submissions from 20 airports proposed
charging infrastructure investment at airports. These proposals are being evaluated and may be
a further extension of longer dwell time parking applications in future investment cycles, if
utilization challenges can be addressed.
Environmental Justice: The concerns, ideas, and recommendations put forward by the
environmental justice community in their comments to CARB and to Electrify America received a
thorough review. Their concerns are addressed in detail throughout Section 4, while many of
their ideas and recommendations are embraced in Section 3 and Section 5.
Other Recommendations Out of Scope: Electrify America also received comments and
proposals that it is not able to act upon in Cycle 1, either due to restrictions on investment in
Appendix C, or because the investments would be outside of this investment plan’s focus on
foundational infrastructure to serve ZEV driver needs. For example, some cities and other
entities requested that Electrify America supply them with ZEVs of various size classes, which
would not qualify as an investment. Additional proposals also recommended Electrify America
invest in Level 1 charging, bicycle programs, and research projects, which are not creditable cost
investments under Appendix C. While these submissions did not fit within the scope or
timetable of the Cycle 1 ZEV Investment Plan, promising ZEV initiatives will be considered in
later investment cycles.
6.5 Regular Updates on Implementation
Electrify America is ready and motivated to begin implementing its Cycle 1 CA ZEV Investment Plan, as it
is now doing with the Cycle 1 National ZEV Investment Plan. Electrify America is developing and will
track a robust set of metrics to not only monitor charger utilization and uptime once the network is
operational, but actual operational performance through our deployment process; these performance
criteria could include site acquisition performance (# of sites needed to achieve one successful sub-
lease) through construction scheduling and spending versus budget allocation. We also plan to survey
and study consumers -- not only existing ZEV drivers, but those considering ZEVs as well -- to understand
Electrify America’s progress in achieving infrastructure awareness and, ideally, incremental ZEV sales
resulting from purpose-placed charging infrastructure and awareness and education campaigns. At six
month intervals, we plan to share results of these metrics with CARB. Electrify America will also provide
28 Supplement to the California ZEV Investment Plan
a short (3-4 page) written status summary at that meeting that does not contain private customer data
or confidential business information and can be shared publically. We are committed to making Annual
and Final Reports available on our website as agreed to in section 3.6 of Appendix C.
29 Supplement to the California ZEV Investment Plan
7 Hydrogen Fuel Cell Vehicle Technology
In its May 24, 2017 letter to Electrify America, CARB requested that Electrify America provide additional
information about its intention to make education and infrastructure investments regarding hydrogen
fuel cell vehicles in the Cycle 1 CA ZEV Investment Plan and in future planning cycles.
Electrify America plans to incorporate
information on attributes of electric drive
vehicles powered by both batteries and
hydrogen fuel cells in its Cycle 1 California-
specific Brand-neutral Public Education and
Outreach activities, as CARB has
requested.5
As detailed above and in the Cycle 1 CA ZEV
Investment Plan, Electrify America is
focusing its ZEV refueling infrastructure
investments on filling the supply-demand
gap to serve the greatest need for ZEV
refueling. As of April 2016, 331 hydrogen
FCEVs were registered with the California
Department of Motor Vehicles [CEC].
California’s Energy Commission and Air
Resources Board jointly project that fuel
cell electric vehicle (FCEV) population will
grow to 18,465 vehicles in 2020 [CEC &
CARB]. To fuel these vehicles, AB 8 requires
California Energy Commission to allocate
$20 million annually to build hydrogen
fueling stations, expanding fueling supply.6
According to the State’s own 2017
projections, California will not have a supply-demand gap for hydrogen refueling in 2020 – in fact it will
have an excess of approximately seven percent.
By comparison, the projected supply-demand gap for plug-in electric vehicles (PEVs) through 2020 is
more than 90 percent. There are a quarter of a million PEVs on California’s roads today, and CEC
projects sales of PEVs to be approximately 200,000 annually over the next five years. Therefore, the
state’s own projections demonstrate that the supply-demand gap for PEV refueling infrastructure is
5 The May 24, 2017 letter from CARB equates “brand neutral” with “technology-neutral.” Brand neutral is defined
in Appendix C as materials that “do not feature or favor Settling Defendants’ vehicles or services.” It does not
reference technology neutrality. Electrify America will incorporate fuel cell technology in its brand-neutral public
education efforts where appropriate.
6 AB 8 directs the California Energy Commission to allocate $20 million per year for hydrogen refueling
infrastructure “until there are at least 100 publically available hydrogen-fueling stations” or until CARB and CEC
determine that “the private sector is establishing publicly available hydrogen-fueling stations without the need for
government support.”
2020 FCEV demand and supply in California
Kg of hydrogen per day
12,800
2020
Excess
-900
13,700
2020
Supply
2020
Demand
“[Our projection] confirms that today’s statewide
network is capable of dispensing more than
enough fuel to satisfy the demand from FCEVs for
the next few years.”
Joint Agency Staff Report, CARB & CEC
January 2017
~74
stations
~18.5k
FCEVs
30 Supplement to the California ZEV Investment Plan
projected to grow rapidly, in comparison to a hydrogen fueling infrastructure gap that has not yet
emerged.
As stated in Section 3, Electrify America will update its analytical models, engage in a robust National
Outreach strategy, and fully explore the merit of all allowable ZEV Investments during the planning and
development of each future ZEV Investment Plan. As part of that process, Electrify America will
reevaluate the degree to which investment in hydrogen refueling infrastructure would address an
existing need, would be economically viable and consistent with Electrify America’s goals, and would be
incremental and additional to existing State of California commitments. Electrify America will meet with
hydrogen station vendors as part of that process, and it will revisit the supply-demand gap analysis.
Electrify America recognizes the potential promise in heavy duty hydrogen projects. Some of the most
promising opportunities are currently in the research, development and demonstration stages at this
time, but Electrify America will continue an open dialogue with the industry to explore whether
investment can be economically justified in future investment cycles.
Finally, Electrify America notes that CARB’s May 24, 2017 letter asks Electrify America to discuss the
potential for siting plazas that allow for both charging and hydrogen fueling stations. CARB did not ask
Electrify America to prioritize such plazas for investment in its February 2017 guidance document, nor
did it communicate this request in our April 27th meeting. However, while Electrify America does not
see clear synergies gained by co-hosting a high-speed charging station and hydrogen refueling station at
the same site, Electrify America will happily engage in dialogue with any hydrogen refueling station site
host in California to explore whether the site would be an appropriate customer-centric, accessible, and
purpose-placed charging station.
31 Supplement to the California ZEV Investment Plan
8 Costs and Other Data Requests
8.1 Creditable Costs
Creditable cost estimates are broken down by the twelve required categories for the entire 30-month
spending cycle within the confidential Cycle 1 CA ZEV Investment Plan submitted on March 8, 2017.
Electrify America’s detailed, multi-year budget is confidential business information. Its public release
could be highly detrimental to Electrify America, as it could provide other ZEV charging infrastructure
companies with a competitive advantage and offer vendors information that could be exploited in
contract negotiations.
8.2 Electrify America’s Business Model
Like other private businesses, Electrify America considers business and revenue models to be critical
pieces of confidential business information. Business and revenue models must also be flexible as
economic requirements dictate. Broadly speaking, Electrify America intends to own and operate most
of its ZEV infrastructure investments, while some investments will be owned, operated, and maintained
by third parties under contract with Electrify America for services rendered. As pricing is a function of
market conditions and Electrify America’s costs, Electrify America would need to gain more information
on the cost of its infrastructure through the RFP process before it could set pricing structures. With
regard to preferential pricing or access concerns, Electrify America intends to create customer-centric
charging stations accessible to all EV drivers, not just Volkswagen drivers. As stated in the Cycle 1 CA
ZEV Investment Plan:
The ZEV infrastructure is intended for, and compatible with ZEV technologies that are not limited
to ones supported by VW group brands. Instead, the goal is to promote universal access to the
extent possible. In particular, multiple technologies (L2, DCFC) and multiple non‐proprietary
connectors and charging protocols (e.g., CHAdeMO, CCS) will be offered to maximize public
access to Electrify America’s charging infrastructure.
8.3 Data Sharing
Electrify America fully intends to share data with CARB regarding cost, utilization, and performance of
ZEV investments, consistent with the content and timing of reporting requirements established in
Section 3.6 of Appendix C. Electrify America will work with CARB to ensure that private customer data
and confidential business information are not released in these reports.
32 Supplement to the California ZEV Investment Plan
8.4 Monitoring and Maintenance of ZEV Investments
Electrify America is implementing a custom-built program management tool to monitor program status
and inform decision making, based on industry best practices. The tool will integrate a number of
Electrify America software systems to allow for efficient reporting and performance tracking. This
includes the integration of customer relationship management (CRM) systems, geospatial tools, project
scheduling, construction management and the network service solution that manages charger
operations. The tool will track targeted metrics such as site selection progress, permit duration,
construction schedule and timelines, on-time charger delivery, hardware vendor performance, charger
utilization, and committed spend amounts.
To ensure ZEV infrastructure investments are maintained at levels that provide high customer
satisfaction, Electrify America will manage network monitoring, call center and on-going maintenance.
8.4.1 Network Monitoring
As part of Electrify America’s software integration efforts, a Request for Proposal (RFP) process is
currently underway for the selection of a network services solution. This solution will support charger
commissioning through operation and maintenance. Specifically, the network operator will be able to
view a variety of functions and outputs to streamline analysis of charger use and customer behavior
using a dashboard, network alerts and ticket management best practices.
Electrify America is planning a robust monitoring and control network system to monitor asset uptime
and ticket resolution time. The network will be designed to support the most effective business process
to minimize network or asset issues and to ensure the information is available to meet strict Service
Level Agreements (SLAs) with internal and external partners to meet metrics, reduce errors, and
providing swift issue resolution.
8.4.2 Call Center
Electrify America will also establish a
multi-language call center to support
end user contacts via phone, email, and
chat. The call center will respond to
consumers inquiring about or utilizing
Electrify America products and services,
and will initiate follow-up
communication where appropriate.
The call center will be evaluated based
on performance metrics, such as (for
Metric type
Charger
issues
Customer call volume (#)
Issues by cause (%)
Resolution rate (%)
Goodwill debits ($)
Customer
service
quality
Speed of answer (minutes)
Call handle time (minutes)
Service level (%)
Customer call center satisfaction (1-10)
Customer service example
metrics tracked
Figure 7: Call Center Metrics (Not Exhaustive)
33 Supplement to the California ZEV Investment Plan
example) calls answered or abandoned, speed to answer, talk time, hold and wait time, time to resolve
call (post initial call), handling time, queue metrics, and chat and email metrics.
8.5 On-going Maintenance
Charger availability is critical to both customer satisfaction and Electrify America’s success, and Electrify
America plans to develop tools and methodology to ensure high levels of network and charger uptime.
Electrify America will be able to rapidly react, review and respond to issues as they occur by utilizing
tools, including diagnostic tools with resolution paths. But Electrify America also plans to be proactive,
with active system monitoring and management of issues, severity classification of issues, and selection
and initiation of the appropriate service level to ensure minimal downtime. Additionally, the call center
agents will be empowered with the capabilities to resolve and report on the majority of customer issues,
often on a single call.
Agents and operators will have access to direct real-time status information about charging stations, and
they will perform tasks such as reviewing unit performance histories, initiating a charge, resetting a
charger, or performing other issue resolution tasks.
Electrify America expects to resolve the majority of support issues via the call center. Upon
encountering an issue that cannot be resolved, a ticket will be generated to the next level support
process. Electrify America may provide preventive and corrective maintenance of its stations utilizing
third parties with credible expertise, where appropriate. Regardless of whether maintenance is
performed in house or by a contractor, Electrify America anticipates setting a goal of resolving minor
matters within 24 hours of a reported problem, while serious matters will be expected to be resolved
within 48 – 72 hours.
8.6 Timelines
The Cycle 1 CA ZEV Investment Plan, submitted March 8th, laid out schedules for investment during the
entire first cycle, which began in January 2017. The Plan presented significant work beginning in the
first half of 2017. It set preliminary milestones for the construction of charging stations in California,
broken down into six month intervals, laying out a firm schedule to complete construction of 400+
stations by the end of the first cycle. In addition, the full Cycle 1 CA ZEV Investment Plan laid out the
Education and Awareness campaign by month. (Advertising purchase schedules are confidential
business information.) Finally, the Cycle 1 CA ZEV Investment Plan laid out a schedule for Green City
Initiative infrastructure construction. Additional detail on the Green City Initiative’s six-month
milestones is provided in Figure 8.
34 Supplement to the California ZEV Investment Plan
Figure 8: Green City Initiative 6-month Milestones
The schedules in the Cycle 1 CA ZEV Investment Plan called for Electrify America’s investment in
California to have already begun. However, Electrify America is not making additional investments
before the Plan is approved, as it is not able to confirm that such investments would be creditable. All
site evaluation and selection work in California has been put on hold indefinitely. The first contracts to
build more than 100 charging stations by the end of 2017 are on permanent hold. And all advertising
buys and other education efforts have been cancelled. As Electrify America and CARB have discussed,
Electrify America will have to restructure its investment schedules and milestones to accommodate this
unexpected delay, and the scale of that adjustment will be dictated by the final date upon which CARB
approves Electrify America to begin investments. Electrify America’s investment in California will be
delayed – but it is not possible for Electrify America to provide a new schedule without knowing CARB’s
timing, or its intention to approve or disapprove the Cycle 1 CA ZEV Investment Plan.
Jan –Jun
2017
Jul –Dec
2017
Jan –Jun
2018
Jul –Dec
2018
Jan –Jun
2019
Launch
ZEV
carshare
service
Issued 40+ ZEV
carshare RFIs
Develop ZEV carshare service
in coordination with vendor
Launch ZEV
carshare
service; then
evaluate and
refine service
offering
Issue ZEV
carshare
RFPs and
select
provider
Set-up
ZEV
charging
infra-
structure
Evaluate and
select ZEV
charging
station sites
Obtain permit
and prepare
charging
station sites
Complete
construction of
ZEV charging
station sites
Comm-
unicate
with stake-
holders
Followed-up with
20+ Green City
related public
submissions
Coordinate and collaborate with
Green City municipal and utility
stakeholders to develop service
Continue to communicate
service to local citizens and
stakeholders
Other
initiatives Explore other Green City initiatives
35 Supplement to the California ZEV Investment Plan
9 Sources
Auto Alliance (2017). Future of Zero Emission Automobiles.
California Center for Sustainable Energy (2013). California Plug-in Electric Vehicle Driver Survey Results.
California Energy Commission (2016). Tracking Progress: Zero-Emission Vehicle and Infrastructure.
http://www.energy.ca.gov/renewables/tracking_progress/documents/electric_vehicle.pdf
California Energy Commission and California Air Resources Board (2017). Joint Agency Staff Report on
Assembly Bill 8: 2016 Assessment of Time and Cost Needed to Attain 100 Hydrogen Refueling
Stations in California. http://www.energy.ca.gov/2017publications/CEC-600-2017-002/CEC-600-2017-
002.pdf
CARB Hearing Transcript, Meeting of the State of California Air Resources Board, Riverside County
Administrative Center, March 24, 2017. https://www.arb.ca.gov/board/mt/2017/mt032417.pdf
CARB (2017). Maps to Support California Climate Investments in Disadvantaged and Low-income
Communities. https://www.arb.ca.gov/cc/capandtrade/auctionproceeds/communityinvestments.htm
Council of Economic Advisors (2009). Estimates of job creation from the American Recovery and
Reinvestment Act of 2009. https://obamawhitehouse.archives.gov/administration/eop/cea/Estimate-of-
Job-Creation/
Friedman, David (2017). Public Plug-in Electric Vehicle Charging Infrastructure Guiding Principles. U.S.
Department of Energy. https://energy.gov/eere/articles/public-plug-electric-vehicle-charging-
infrastructure-guiding-principles
Giles, Cynthia, Assistant Administrator Office of Enforcement and Compliance Assurance and Janet
McCabe, Acting Assistant Administrator U.S. Environmental Protection Agency. Written Testimony
before the Subcommittee on Oversight and Investigations Committee on Energy and Commerce. U.S.
House of Representatives, December 6, 2016.
Giles, Cynthia, Assistant Administrator, Office of Enforcement and Compliance Assurance, U.S.
Environmental Protection Agency. Oral Testimony before the Subcommittee on Oversight and
Investigations Committee on Energy and Commerce. U.S. House of Representatives, December 6, 2016.
Hummel, Patrick, et al. (2017). UBS Evidence Lab Electric Car Teardown – Disruption Ahead? UBS.
McKinsey Sustainable Mobility Initiative (2016). Electrified Vehicle Consumer Surveys.
National Academy of Sciences (2015). Overcoming Barriers to Deployment of Plug-in Electric Vehicles.
National Academy of Sciences (2013). Overcoming Barriers to Electric Vehicle Deployment – Interim
Report.
36 Supplement to the California ZEV Investment Plan
Office of Legislative Counsel (2016). Assembly Bill No. 1550, Chapter 369, An Act to amend Section
39713 of the Health and Safety Code, relating to greenhouse gases. Legislative Counsel’s Digest.
https://leginfo.legislature.ca.gov/faces/billNavClient.xhtml?bill_id=201520160AB1550
Shaheen, Susan; Elliot Martin; and Apaar Bansal (2015). Zero and Low-emission Vehicles in the U.S.
Carsharing Fleets: Impacts of Exposure on Member Perceptions. Transportation Sustainability Research
Center, University of California – Berkeley.
Sheldon, Tamara; J.R. DeShazo; Richard T. Carson, and Samuel Krumholz (2015). Factors Affecting Plug-
in Electric Vehicle Sales in California. UCLA Luskin Center for Innovation.
http://innovation.luskin.ucla.edu/content/factors-affecting-plug-electric-vehicle-sales-california
Steinberg, Darrell and Howard Chan. Comments Regarding Volkswagen’s California Zero Emission
Vehicle Plan, April 5, 2017. https://www.arb.ca.gov/lists/com-attach/12-vwzevinvestplan-ws-
VSNVJFY+V2oKegFk.pdf
Strategic Vision (2016). New Vehicle Experience Survey.
Turek, Alex; George M. DeShazo; Wally Siembab; and Aaron Baum (2017). Assessing the Multi-Unit
Dwelling Barrier to Plug-in Electric Vehicle Adoption in the South Bay, DRAFT. UCLA Luskin Center for
Innovation. http://southbaycities.org/sites/default/files/ARV-14-035%20ZEV%20MUD%20-%20Final-
Draft%20Rpt_0.pdf
US Department of Energy (2015). Workplace Charging Challenge – Mid-program Review: Employees
Plug-in. https://energy.gov/sites/prod/files/2015/12/f27/105313-5400-BR-0-
EERE%20Charging%20Challenge-FINAL_0.pdf
US Department of Transportation (2014). GROW AMERICA Act: Creating a pathway to transportation
careers.
https://www.transportation.gov/sites/dot.gov/files/docs/Workforce_DOT_Reuth_FINAL_2014.pdf
Williams, Bill. California ZEV Investment Plan Cycle One as submitted by Volkswagen. San Joaquin
Valley Electric Vehicle Partnership, April 10, 2017. https://www.arb.ca.gov/lists/com-attach/87-
vwzevinvestplan-ws-USIAbFUiWG5SIgV1.pdf
Williams, B., Anderson, J., Santulli, C., and Arreola, G. (2015). Clean Vehicle Rebate Project Participation
Rates: The First Five Years (March 2010--March 2015). Center for Sustainable Energy, San Diego CA.
https://cleanvehiclerebate.org/sites/default/files/docs/nav/transportation/cvrp/survey -results/2015-
10%20CVRP%20Participation.pdf