Loading...
HomeMy WebLinkAboutKing Cove 2012-VEEP1 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove Village Energy Efficiency Program AEA VEEP Grant #7520001 Administered by Alaska Building Science Network King Cove Final Report Grant Amount: $150,000 Center Photo: ©State of AK Division of Community and Regional Affairs Community Summary 3 community buildings and 1 public facility received energy efficient lighting and weatherization upgrades as follows: Agdaagux Tribe of King Cove Office, King Cove Bible Chapel Church,The King Cove Corporation Hotel, City of King Cove Street Lights Retrofits Completed:November 2011 Street Light Retrofits Completed:June 2012 Village-Wide Energy Efficient Lighting and Weatherization Retrofit Summary: • Projected Annual Electrical Savings (kWh):55,386 • Projected Annual Electrical Cost Savings:$14,4001 •Projected Annual Heating Fuel Savings (gallons):2,241 •Projected Annual Fuel Cost Savings:$10,4652 • Total Projected Annual Energy Cost Savings:$24,866 • Total village wide In-kind contribution:$17,870 • Total project cost including In-kind contribution: $167,870 • Simple Payback (including In-kind contributions):6.75 years 1 kWh Rate [used to calculate electrical cost savings] for Lighting Measures (State of AK -AEA PCE Program Report FY 2011 avg):$0.26 2 #2 Heating Fuel Rate [used to calculate heating fuel savings] (AkWarm Library): $4.67/gal 2 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove AGDAAGUX TRIBE OWNED BUILDINGS AND FACILITIES Agdaagux Tribal Council Office Total Building Savings All Measures: • Projected Annual Electrical Savings (kWh):1,127 • Projected Annual Electrical Cost Savings:$293 • Projected Annual Heating Fuel Savings (gallons):2,241 • Projected Annual Fuel Cost Savings:$10,465 • Total Projected Annual Energy Cost Savings:$10,758 Lighting Retrofit Summary: Materials Installed Quantity Fluorescent 2-lamp electronic ballast, (2) 25 watt T8 lamps 7 Fluorescent 3-lamp electronic ballast, (3) 25 watt T8 lamps 2 Fluorescent 4-lamp electronic ballast, (4) 25 watt T8 lamps 1 CFL-20 W 1 CFL-23 W 2 Occupancy Sensors 2 • Pre-retrofit energy use for all lighting:1.270 Kilowatts • Post-retrofit energy use for all lighting:0.626 Kilowatts • Energy savings projection:0.644 Kilowatts • Pre-retrofit to post retrofit energy reduction:51% • Estimated Annual Savings:kWh Saved: 1,127 Comparative Comparative Hours Per Day /Electrical Avoided Diesel Avoided Diesel 250 Days Per Year Savings Use (gal)Costs 4 Hours/day $167.44 58.28 $180.67 7 Hours/day $293.02 101.99 $316.17 10 Hours/day $418.60 145.70 $451.67 2000 Hours/year (Est.)$334.88 116.56 $361.34 3 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove Agdaagux Tribal Council Office Weatherization Retrofit Summary: •Added R-31 loose-fill blow-in fiberglass insulation in attic. • Added R-19 fiberglass batt insulation and sheathing to damaged original floor; also, installed insulated skirting with protective metal flashing. • Air sealed building to reduce air leakage. • Annual energy savings projection:2,241 gallons • Estimated Annual Heating Fuel Cost Savings:$10,465 4 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove BIBLE CHAPEL CHURCH OWNED BUILDINGS AND FACILITIES King Cove Bible Chapel Church Lighting Retrofit Summary: Materials Installed Quantity Fluorescent 2 ft fixture, 4-lamp electronic ballast, (4) 17 watt T8 lamps 1 Fluorescent 4-lamp electronic ballast, (4) 25 watt T8 lamps 8 CFL-11 W 3 CFL-15 W 26 CFL-27 W 2 • Pre-retrofit energy use for all lighting:3.693 Kilowatts • Post-retrofit energy use for all lighting:1.257 Kilowatts • Energy savings projection:2.436 Kilowatts • Pre-retrofit to post retrofit energy reduction:66% • Estimated Annual Savings:kWh Saved: 4,263 Comparative Comparative Hours Per Day /Electrical Avoided Diesel Avoided Diesel 250 Days Per Year Savings Use (gal)Costs 4 Hours/day $633.36 220.45 $683.40 7 Hours/day $1,108.38 385.79 $1,195.95 10 Hours/day $1,583.40 551.13 $1,708.51 Hours/year (Est.) *Note:The community of King Cove opted to purchase materials and provide labor In-kind to complete energy efficiency retrofits for the Bible Chapel Church. To further maximize the value of the VEEP & EECBG, Alaska Building Science Network provided energy audits of various community buildings not included under VEEP/EECBG funding upon local request, while providing technical support and training as needed to complete upgrades. 5 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove KING COVE CORPORATION OWNED BUILDINGS AND FACILITIES King Cove Corporation Hotel Lighting Retrofit Summary: Materials Installed Quantity Fluorescent 2-lamp electronic ballast, (1) 25 watt T8 lamp 1 Fluorescent 2-lamp electronic ballast, (2) 25 watt T8 lamps 24 Fluorescent 3-lamp electronic ballast, (2)25 watt T8 lamps 5 Fluorescent 3-lamp electronic ballast, (3) 25 watt T8 lamps 4 Fluorescent 4-lamp electronic ballast, (4) 25 watt T8 lamps 3 CFL-14 W 1 CFL-16 W 38 CFL-19W 5 CFL-27 W 4 Occupancy Sensors 3 • Pre-retrofit energy use for all lighting:8.204 Kilowatts • Post-retrofit energy use for all lighting:2.781 Kilowatts • Energy savings projection:5.423 Kilowatts • Pre-retrofit to post retrofit energy reduction:66% • Estimated Annual Savings:kWh Saved: 9,490 Comparative Comparative Hours Per Day /Electrical Avoided Diesel Avoided Diesel 250 Days Per Year Savings Use (gal)Costs 4 Hours/day $1,409.98 490.77 $1,521.38 7 Hours/day $2,467.47 858.85 $2,662.42 10 Hours/day $3,524.95 1226.92 $3,803.46 1500 Hours/year (Est.)$2,114.97 736.15 $2,282.08 *Note:King Cove Corporation opted to purchase materials and provide labor In-kind to complete energy efficiency retrofits for the Corporation Hotel. To further maximize the value of the VEEP & EECBG, Alaska Building Science Network provided energy audits of various community buildings not included under VEEP/EECBG funding upon local request, while providing technical support and training as needed to complete upgrades. 6 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove CITY OF KING COVE OWNED BUILDINGS AND FACILITIES City of King Cove Street Lights Lighting Retrofit Summary: Retrofitted 68 HPS (High-Pressure Sodium) street light fixtures with energy efficient LED (Light-Emitting Diode) street light fixtures –to include 20-year photo sensors. Pre-retrofit energy use for all street lighting:55,994 kWh Post-retrofit energy use for all street lighting:15,488 kWh Energy savings projection:40,506 kWh Pre-retrofit to post-retrofit energy reduction:72% Estimated Annual Savings:$10,532 7 Alaska Building Science Network –Village Energy Efficiency Program –’10-’12 Final Report –King Cove In-Kind Item Dates Hours Contri- buted Hourly Wage $Value / Amount Notes Staff time for project contact, introduction & review of intro materials 3 $ 20.00 $ 60.00 Number of entities x 1 hour each Staff time for Attending teleconference 10/28/2010 1 $ 20.00 $ 20.00 City time Staff time for Attending teleconference 10/28/2010 1 $ 20.00 $ 20.00 TC/IRA time Staff time for Attending teleconference 10/28/2010 1 $ 20.00 $ 20.00 Village Corp time Maint. Staff time to accompany Field Manager on building assessment November '10 7 $20.00 $ 140.00 City: Pick-up @ airport (1 hr), Open up hydro plant and water treatment facilities (3 hrs), Provide ladder and public works access (1 hr); Corp: Open up doors in the hotel (2 hrs) - 1st assessment site visit Conservative village office administrative and other project support - percentage of total project cost less ABSN Admin %. Total project cost = $150000 - (our admin percentage, (around 14%) Approx: $21,000) = $129,000 x 4% = $5,160 (this 4% village admin cost estimate is spread across all entities we work with for the course of the grant for completing all energy efficiency measures). These are for cumulative, otherwise unaccounted time expense for village - based project support. Feb, '09 through Completion $ 5,160.00 Each time we call, email, or fax a village entity, someone receives the communication, reviews and/or forwards the information, follows-up on requests, etc. Whether it is to set-up a teleconference, verify maintenance staff participation in lighting or boiler trainings, set-up in-kind lodging and transportation, lighting trainings, track a shipment, ship lamps and ballasts out of the village for recycling, request a labor reimbursement agreement, or invoice etc, send additional photos of completed work, etc. Village expenses for phone charges, copying and fax costs, office supplies, etc. are part of this amount. Lodging for ABSN Field Managers 11/2/10 - 11/8/10 4 $50.00 $ 200.00 City: Lodging for 2 people in multipurpose bldg (Elders room) - 1st assessment site visit Transportation and fuel costs 11/2/10 - 11/8/10 $ 400.00 City: Use of vehicle 24/7, plus fuel - 1st assessment site visit Lodging for ABSN Field Managers November '11 7 $110.00 $ 770.00 Tribe: Fleets Inn Hotel - Weatherization/Lighting Upgrades Employer share of payroll contributions November '11 $ 380.28 Tribe: Payroll Taxes Employer (Fica 6.2 Med 1.45 ESC 2.92 = .1057 x 3597.75) - Weatherization/Lighting Upgrades Labor for street light retrofits June - July '12 68 $150.00 $ 10,200.00 City: Installation - Street Lighting Upgrades Office Manager / Staff time for street light retrofits February - July '12 20 $25.00 $ 500.00 City: Coordination - Street Lighting Upgrades TOTAL $17,870.28 King Cove, In-Kind Contribution Tracking Record - ABSN Energy Efficiency Projects: