Energy Conservation
Energy conservation probably offers you the largest cost savings of any in this guide.
This shouldn’t discount any other chapters; rather, it should tell you that energy
conservation activities should not be left out when making changes and improve-
ments in your workplace.
A general breakdown of energy use in commercial facilities, according to the U.S.
Department of Energy, shows that heating (22%), cooling (18%, and ventilation (5%)
together comprise about 45% of your energy expenditures. Lighting is another big
expenditure at 31%. The remaining quarter of energy use is divided among a handful
of activities including refrigeration (3%), water heating (7%), running office equip-
ment (6%), cooking (2%), and others (6%).
Compared to this national average, Anchorage’s standard office buildings use slightly
more energy for heating and lighting, and slightly less energy for cooling. Overall,
the totals are comparable to the national average.
The major areas where you can make an impact on energy usage are lighting, heating,
and cooling.
Lighting
•Install more efficient types of lighting. Replace incandescent bulbs with
compact fluorescent lamps (CFLs). Almost 90% of the energy used by an incan-
descent bulb is released as heat rather than light. CFLs use 75% to 80% less
energy while lasting 10 to 15 times longer. They come in dimmable varieties,
outdoor models, and shapes and sizes that fit almost all types of fixtures. You also
can replace your fluorescent tubes with more efficient T-8 or T-5 sizes. These
smaller tubes give off more light using less energy. If you replace standard T-12
lamps with T-8 lamps in a 50,000 sq. ft. facility, you can save $54,000 over the
life of the lamps.
. . . . . . . . . . . 6
Did You Know….Did You Know….Did You Know….Did You Know….Did You Know….
If all of corporate America installed energy efficient lighting systems...
… between 40% and 75% of lighting-related pollution would be prevented.
… approximately $250/year in energy costs per square foot of floor space would be saved.
… about $19 billion would be saved nationwide every year.
… smog would be reduced by 10%, which is equivalent to taking 42 million cars off the
road for one year.
1818
•Reduce wattage used in
your facility. To lower
energy bills, check the
wattage of lighting, as well
as the number of fixtures,
and determine if some
could be removed or re-
placed with lower- wattage
lamps. Installing reflectors
is an extremely cost-
effective way to maximize
light output without in-
creasing energy use. The
efficiency of any lamp can
be improved by 50% by
simply installing reflectors
on each lamp.
•Reduce the light
source’s “on” time.
You can install switches in
numerous convenient areas
to make it easier for people
in large shared spaces to
turn off lights in unused
areas. You also can install
more sophisticated sys-
tems, including photocells
that turn lights on and off
in response to natural light
levels; mechanical or electronic time clocks that automatically turn on and off
lights; timers; occupancy sensors that activate lights when a person is in the area; or
dimmers to reduce the wattage and output of incandescent and fluorescent lamps.
Don’t forget to educate staff about turning off unnecessary lighting. See Chapter 11
for a list of local companies that can provide lighting controls.
“According to the U.S. EPA Green Lights
program, businesses tend to overlight.”
•Perform simple maintenance. Cleaning lamps and fixtures, or repainting
rooms with a light color can brighten areas considerably. Also consider group
relamping instead of replacing lamps individually as they die. Incandescent and
fluorescent lamps can lose 20 to 30 percent of their light output over their life.
Lighting experts recommend replacing all the lamps in a lighting system at once.
This saves labor, keeps illumination high, and avoids stressing any ballasts with
dying lamps.
GREEN STARS
ConocoPhillips Alaska
•Removed extra bulbs and installed reflectors in light
fixtures to cut electrical usage by 60% while increas-
ing light output.
•Replaced incandescent bulbs with compact
fluorescents, yielding an annual savings of $45,000.
AMC Engineering
•Installed 34-watt energy-saving fluorsecent lamps
throughout the office, recouping the cost of the
relamping project in just two months.
Alaska Communications Systems
•Reduced electric bills by 11.5% by converting from
40-watt to 34-watt fluorescent lamps and converting to
electronic ballasts.
U.S. Army Engineer District, Alaska
•Installed occupancy sensors in conference rooms and
utility closets for an estimated savings of $16,900 per
year.
Westmark Hotels
•Replaced all incandescent bulbs in public areas and
guest rooms with fluorescent lamps. This saved 66
watts per fixture in over 800 fixtures in public areas,
and 300 watts per room.
1919
•Use daylighting to replace artificial light sources. The more daylight you
can use, the less electricity you will need to use for lighting. Take advantage of
Anchorage’s long summer days to reduce your lighting costs. This can mean
opening drapes and blinds, and installing skylights and additional windows. Make
sure that any new windows are insulated and properly coated so that you aren’t
spending the money on heating that you saved on lighting.
Heating, Ventilation, and Air Conditioning (HVAC) Systems
HVAC system improvements offer the greatest potential for energy savings in most
facilities. See Chapter 11 for a list of energy consultants and audit services available.
•Consider equipment improvements and changes. Look at the newest
technologies for heating and cooling. Many of these are very energy efficient. For
example, ground heat pumps can heat a building in winter and cool it in summer
using the temperature of the earth. Local energy consultants can provide informa-
tion about the latest technologies.
•Install temperature controls. Like lighting controls, temperature controls help
to control systems in unoccupied areas or in several different systems in one
building. Controls include programmable thermostats, clock timers and manual
timers.
GREEN STARS
AIDEA/Alaska Energy Authority
•Replaced older lighting fixtures with compact fluorescents and more efficient T-8 lamps
on several floors. Savings in the first two months of 2002, compared to January and
February 2001, were about 25 to 30%.
ConocoPhillips Alaska
•Installed energy-efficient boilers, saving $100,000 in annual gas bills.
AMC Engineers
•Adjusted the location of some of the office’s thermostats to regulate heat more evenly.
Anchorage Water and Wastewater Utility, Engineering Division
•Integrated a Direct Digital Control system with the HVAC system, which allows for
maximizing the heating efficiencies and for reduction in heat use during non-occupancy
periods.
•Implemented an alternative operating program at the Eagle River Wastewater Treatment
Facility including reducing thermostat settings, continuously turning lights and equipment
off when not in use, modified operations of the larger air exchange units throughout the
plant, and heating systems were modified to use smaller, more efficient local heaters. The
efforts resulted in reduced energy use and annual savings of about $40,000.
•Installed a vinyl curtain in a stairway landing to keep hot air from rising to the second story
of the King Street administrative building. This eliminated the need to use electric fans on
the second floor and stabilized temperatures in the two areas.
2020
•Install Energy Management Systems. EMSs allow you to monitor and
control energy use in your facility using a computerized system. Direct digital
control HVAC systems are good for large facilities; significant money can be saved
by EMS features that limit demand charges by shutting down parts of the facility
during certain times of day.
•Investigate commissioning. Commissioning is a systematic process of inspec-
tion, testing, and training conducted to confirm that a building and its component
systems are capable of being operated and maintained in conformance with the
design intent. Usually commissioning occurs within the first year of a building’s
operation and is done independently of all others involved with the facility. It
should, however, be done periodically and on older buildings as well.
•Investigate alternative energy sources. Wind and solar power are two alter-
native energy sources that tap into renewable energy production. Passive and
active solar systems are available. Solar panels can be installed to supplement hot
water heating systems or can be used to operate parking lot lighting, among other
applications. Wind power may soon be available on a large scale through local
power companies. Contact Chugach Electric at 762-7876 to find out more about
the possibility of purchasing power generated using wind power.