HomeMy WebLinkAboutKing Cove, Alaska Dischage Measurement June 1985 Field TripKING COVE, ALASKA DISCHARGE MEASUREMENT JUNE 1985 FIELD TRIP - PRO'-'ECT NAME RIVER NAME TRANSECT NO. KING COVE HYDROELECT DELTE CREEK GAGE SITE-6/12/85 PT. STATION WIDTH <FEET> CFEET> ------------ 1 2. 50 0.00 2 3.00 0.75 3 4.00 1. 00 4 5.00 1. 00 5 6.00 1. 00 6 7.00 1. 00 7 8.00 1. 00 a 9.00 1. 00 9 10.00 1. 00 10 11.00 1. 00 11 12.00 1. 00 12 13.00 1. 00 13 14.00 1. 00 14 15.00 1. 00 15 16. 00 1. 00 16 17. 00 1. 00 17 18.00 1. 00 18 19.00 1. 25 19 20. 50 0.00 SUM OF CELL DISCHARGES -40.89 SUM OF CELL AREAS -19.22 MEAN VELOCITY = 2. 13 DEPTH VELOCITY AREA DISCHARGE CFEET> <FT/SEC> CSG.FT) CCFS) ----------------------------- 0.00 0.00 0.00 0.00 0. 70 0. 40 0. 52 0.21 0.80 -0.20 0.80 -o. 16 0.90 1. 50 0.90 1. 35 1. 00 2.30 1. 00 2.30 1. 30 2.40 1. 30 3. 12 1. 40 2. 10 1. 40 2.94 1. 60 2.20 1. 60 3. 52 1. 70 2.60 1. 70 4.42 1. 50 3. 30 1. 50 4.95 1. 40 3. 30 1. 40 4.62 1. 40 2.60 1. 40 3.64 1. 30 2. 50 1. 30 3.25 1. 10 2.30 1. 10 2. 53 1. 10 1. 60 1. 10 1. 76 0.90 1. 40 0.90 1. 26 0.80 1. 10 0.80 0.88 0.40 0.60 0. 50 0.30 0.00 0.00 0.00 0.00 CUBIC FT. /SEC. SQUARE FT. FT. /SEC. ~ A!ttll A R~ "' ··'····A :~ ;l slrli -~ 1.':. PRELIMINARY ANALYSIS STAG£ DATA & CORRESPONDING DISCHARGES • , .. i :;_ ~ ~ PROPOSED KING COVE HYD~OELECT~IC PROJEC DELTA CREEK NEAR KING COVE,ALAS~A DATE TIME ----=-·=------01/02/85 02:00 01/02/85 04:00 01/02/85 06:00 01/02/85 08:00 01/02/85 10:00 01102/85 12: 00 01/02/85 14:00 01/02/85 16:00 01102/85 18: 00 01102/85 20: 00 01/02/85 22:00 01102/85 00: 00 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 01/03/85 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00 00:00 01/o.li'S' 02: oo Ot/04185 04: 00 01/04/85 06:00 01/04/85 08:00 01/04/85 10:00 01/04/85 12:00 01/04/85 14:00 01/04/85 16:00 01/04/85 18:00 01104/85 20: 00 01/04/85 22:00 01/04/85 00:00 B'r'fE RAW DATA :z:=::::::= ===:::u:s::z::r: 009 35 010 35 011 35 012 34 013 34 014 34 015 34 016 34 017 34 018 33 019 33 020 33 DAILY AVERAGE VALVES 021 33 022 33 023 33 024 33 025 33 026 33 02"1 32 028 33 029 32 030 32 031 32 032 32 DAILY AVERAGE VALUES 033 32 034 32 035 32 036 32 037 31 038 31 039 31 040 31 041. 31 042 31 043 31 044 31 DAILY AVERAGE VALUES DEPTH FEET ======-= 1. 75 1. 75 1. 75 1. 70 1. 70 1. 70 1. 70 L 70 1. 70 1. 65 1. 65 1. 65 1. 70 1. 65 1. 65 L 65 1. 65 L 65 L 65 1. 60 1. 65 L 60 1. 60 L 60 1. 60 1. 63 1. 60 1. 60 1. 60 1. 60 1. 55 1. 55 1. 55 1. 55 1. 55 1. 55 1. 55 1. 55 1. 57 I O~tJB/8~ PA~t ' 2~ START TIME 10/10/84 02:00 STAGE FEET ===== L 75 1. 75 1. 75 i. 70 1. 70 1. 70 1. 70 1. 70 1. 70 1. 65 1. 65 1. 65 1. 70 1 65 1. 65 1. 65 1. 65 1. 65 1. 65 1. 60 1. 65 1. 60 1. 60 1. 60 1. 60 1. 63 1. 60 1. 60 L 60 1. 60 1. 55 1. 55 1. 55 L 55 1. 55 1. 55 1. 55 1. 55 L 57 DISCHG CFS ==:=::== 36 36 36 34 34 34 34 34 34 31 31 31 34 31 31 31 31 31 31 29 31 29 29 29 29 30 29 29 29 29 27 27 27 27 27 27 27 27 28 P"i'~ n ..,_-: tt~~_·,- ~ ~.· ~--~ , I ·~ .· ') PROJOSEO K~NG co0E HYDR10ELF.:CTk IC PR6.JEC ' ():_;., Jei8:J PAo..:;t:. . 30 DELTA CREEK NEAR KING COVE, ALASKA START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ~~~===== ===~= ==~= ~-====··= ====2= ===~-===·== 01/05/8~ 02:00 045 31 1. 55 1. 55 27 01/05/85 04:00 046 31 1.55 1. 55 27 01/0~/85 06:00 047 30 1.50 1. 50 25 01/05/85 08:00 048 31 1. 55 1. 55 27 01/05/85 10:00 049 30 1. 50 1. 50 25 01/05/85 12: 00 050 30 1. 50 1. 50 25 I'\. ' • 01105/85 14: 00 051 30 1. 50 1. 50 25 tf' o1to~18s 16: oo os2 3o 1. 5o 1 5o 2s 1 01/0~/8~ 18:00 053 30 1. 50 1. 50 25 01/05/85 20:00 054 30 1. 50 1. 50 25 01/05/85 22:00 055 30 1. 50 1.50 25 01/05/85 00:00 056 30 1. 50 1. 50 25 DAILY AVERAGE VALUES 1.51 1. 51 26 01/06/85 02:00 057 30 1. 50 1. 50 25 01/06/85 04.00 058 30 1.50 1. so 25 01/06/85 06:00 059 30 1.50 1. 50 25 01/06/85 08: 00 060 30 1. 50 1. 50 25 01/06/85 10:00 061 30 1. 50 1. 50 25 01/06/85 12:00 062 30 1.50 1. 50 25 01/06/85 14:00 063 30 1.50 i. 50 25 01/06/85 16:00 064 30 1. 50 1 50 25 01/06/85 18:00 065 31 1. 55 1. 55 27 01/06/85 20: 00 066 32 1. 60 L 60 29 01/06/85 22:00 067 32 1.60 1.60 29 01/06/85 00: 00 068 32 1. 60 1. 60 29 DAILY AVERAGE VALUES 1. 53 1. 53 26 01107185 02: 00 069 32 1. 60 1. 60 29 0110'1195 04: 00 070 33 1. 65 1. 65 31 01/07/85 06: 00 071 32 1. 60 1. 60 29 01107/85 08:00 072 31 1. 55 1. 55 27 01/07/85 10:00 073 3i 1. 55 i. 55 27 01/07/85 12:00 074 30 1. 50 i. 50 25 01107/85 14:00 075 30 1. 50 L 50 25 ,. 01107/85 16: 00 076 30 1. so 1. 50 25 01/07/85 18:00 077 30 1.50 1. so 25 01/07/85 20:00 078 30 1. 50 1. 50 25 01107/85 22:00 079 30 1. 50 i. 50 25 1., 01/07/85 00: 00 080 30 1. 50 1. 50 25 DAILY AVERAGE VALUES 1. 54 1. 54 27 I 1 t ' -· I PROPbSED KlNG coJE HYDR'oELtCihic t'HJJEC I 0 ;.u u'B /8;; 'PAI.:rc:. 31 DELTA CREEK NEAR KING COVE.ALASKA START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS •••••••• ma:;r:;:c:ca: ===== ====·===~ ===-=== =r::=== =====::::::== 01/08/85 02:00 081 30 1. 50 1. 50 25 01/08/85 04:00 082 30 1. 50 1 50 25 01/08/85 06:00 083 30 1. 50 1. 50 25 D •: ._,., "''· f' 01/08/85 08: 00 084 30 1. 50 1. 50 25 01108/85 10: 00 085 29 1. 45 1. 45 23 I 01/08/85 12:00 086 29 1. 45 i. 45 23 01/08/85 14:00 087 29 1. 45 1. 45 23 01/08/85 16:00 088 29 1. 45 1. 45 23 01/08/85 18:00 089 29 1. 45 1. 45 23 01/08/85 20:00 090 29 1. 45 i. 45 23 01/08/85 22:00 091 29 1. 45 1. 45 23 01108/85 00:00 092 29 1.45 1 45 23 DAILY AVERAGE VALUES 1. 47 1. 47 24 01/09/85 02:00 093 30 1. 50 1. 50 25 01/09/85 04:00 094 29 1. 45 i. 45 23 01/09/85 06:00 095 29 1. 45 i. 45 23 01/09/85 08:00 096 30 1 50 1. 50 25 01/09/85 10:00 097 30 1. 50 1. 50 25 01/09/85 12:00 098 30 1. 50 1. 50 25 01/09/85 14:00 099 30 1. 50 1. 50 25 01109/85 16: 00 100 29 1. 45 1. 45 23 01109/85 18: 00 101 29 1. 45 1. 45 23 01/09/85 20:00 102 29 1. 45 1. 45 23 01109/85 22:00 103 29 1. 45 1. 45 23 01/09/85 00:00 104 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 47 1. 47 24 01/1~95 02:00 105 29 1. 45 1. 45 23 01/10/85 04:00 106 29 1. 45 1. 45 23 01110/85 06:00 107 29 1. 45 1. 45 23 01/10/85 08:00 108 29 1.45 1. 45 23 01/10/85 10:00 109 29 1. 45 1. 45 23 01/10/85 12:00 110 29 1. 45 1. 45 23 01110/85 14:00 111 28 1. 40 1. 40 21 01110/85 16: 00 112 29 1. 45 i. 45 23 01/10/85 18:00 113 29 1. 45 1. 45 23 01/10/85 20:00 114 29 1. 45 1. 45 23 01/10/85 22:00 115 29 1. 45 1. 45 23 01/10/85 00:00 116 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 45 1. 45 23 h-.urloSE ...... J:NG ~..., iE 1-•. ~.JOEL~~.~ lC ... 1JEt ( 13/8 PA• 3• DELTA CREEK NEAR KING COVE,ALASKA START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS :z:e===~= ===e== ==== ======::::::::.::-==:=== ====== ==:=e=== 01/17/85 02:00 189 31 1. 55 1. 55 27 01/17/85 04:00 190 31 1. 55 1. 55 27 01/17/8~ 06:00 191 30 1. ,0 1. ~0 2~ 01117/85 08:00 192 30 1. 50 1. 50 25 01/17/85 10:00 193 30 1. 50 1. 50 25 01/17/85 12:00 194 29 1. 45 1. 45 23e~·-... 01/17/85 14:00 195 30 1. 50 1. 50 . ,1 :·~ 25 ~ ..... "' ;:~.,.. . . . 01/17/85 16:00 196 30 1. 50 1. 50 . ft~ :' ;l ~· ~ ' 25. ML~'~.,~~.,r:.: · •:. 01/17/8~ 18:00 197 30 1. 50 1. 50 25'. l\l~.,_w .. M.,,. -'<. 01117/85 20:00 198 30 1. 50 1. 50 25 01/17/85 22:00 199 30 1. 50 1. 50 25 01/17/85 00:00 200 30 1. 50 1. 50 25 DAILY AVERAGE VALUES 1. 50 1. 50 25 01/18/85 02:00 201 30 1. 50 1. 50 25 01/18/85 04:00 202 30 1. 50 1. 50 25 01/18/85 06:00 203 30 1. 50 1. 50 25 01/18/85 08~00 204 30 1. 50 1. 50 25 01118/85 10:00 205 30 1. 50 1. 50 25 01/18/85 12:00 206 30 1. 50 1 50 25 01/18/85 14:00 207 30 1. 50 1. 50 25 01/18/85 16:00 208 30 1. 50 1. 50 25 01/18/85 18:00 209 30 1 50 1. 50 25 01/18/85 20:00 210 29 1. 45 1. 45 23 01118/85 22:00 211 29 1. 45 1. 45 23 01/18/85 00:00 212 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 49 1. 49 25 01/1~('85 02:00 213 29 1. 45 1. 45 23 0111~5 04: 00 214 29 1. 45 1 45 23 01 I 1 4P/85 06: 00 215 29 1. 45 1. 45 23 01/19/85 OS: 00 216 29 1. 45 1. 45 23 011141/85 10:00 217 29 1. 45 1. 45 2:'3 -01/19/85 12:00 218 29 1 45 1. 45 23 01/19/85 14:00 219 29 1. 45 1. 45 23 01/19/85 16:00 220 29 1. 45 1. 45 23 01/19/85 18:00 221 29 1. 45 1. 45 23 01119/85 20:00 222 29 1. 45 1. 45 23 01/19/85 22:00 223 29 1. 45 i. 45 23 01/19/85 00:00 224 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 45 1. 45 23 FnurbSEu n\NG ~u ~ bEL ~-~ 1JE-'".._, ... -· --·;"LC .,,'"j l. (. SiB. PA1 3: DELTA CREEK NEAR KING COVE.ALASKA START TIME 10/10i84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ••••ssS'IIa ••••• ~==::::= =========== ====== ===== ====== 01120/85 02: 00 225 29 1 45 1. 45 23 01/20/85 04:00 226 29 1. 45 1. 45 23 01/20/85 06:00 227 29 1. 45 1. 45 23 01/20/85 08:00 228 29 1. 45 1. 45 23 01/20/85 10: 00 229 29 1. 45 1. 45 23 01/20/85 12:00 230 29 1. 45 1. 45 23 01/20/85 14:00 2:11 29 1. 45 1. 45 23 p--. 01/20/85 16:00 232 29 1. 45 1. 45 23 ~: :t f .. 01/20/85 18:00 233 29 1. 45 1. 45 23 ~·. ii{ .. 01/20/85 20:00 234 29 1. 45 1. 45 23 .. ~ 01/20/85 22:00 235 29 1. 45 1. 45 23 01/20/85 00:00 236 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1.45 1. 45 23 01121/85 02: 00 237 29 1. 45 L 45 23 01/21/85 04:00 238 29 1. 45 1. 45 23 01/21185 06: 00 239 29 1. 45 1. 45 23 01/21/85 08:00 240 29 1. 45 1. 45 23 01/21/85 10:00 241 29 1. 45 1. 45 23 01/21/85 12: 00 242 28 1. 40 1 40 21 01/21/85 14:00 243 29 1. 45 1. 45 23 01/21/85 16:00 244 28 1. 40 1. 40 21 01/21/85 18: 00 245 29 1. 45 1. 45 23 01/21/85 20:00 246 28 1. 40 1. 40 21 01/21/85 22:00 247 28 1. 40 1. 40 21 01/21185 00: 00 248 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 43 1. 43 22 01/~85 02:00 249 28 1. 40 1. 40 21 0112 Iss o4: oo 250 28 1.40 1 40 21 01/22/85 06:00 251 28 1. 40 1. 40 21 01122/85 08:00 252 28 1. 40 1. 40 21 01/22/85 10:00 253 28 1. 40 1. 40 21 01/22/85 12:00 254 28 1. 40 1. 40 21 01122/85 14:00 255 28 1. 40 1. 40 21 01122/85 16: 00 256 28 1. 40 1. 40 21 01/22/85 18:00 257 28 1. 40 1 40 21 01/22/85 20: 00 258 28 L 40 1. 40 21 01/22/85 22:00 259 28 1. 40 1. 40 21 01/22/85 00:00 260 28 1. 40 1 40 21 DAILY AVERAGE VALUES 1. 40 1. 40 21 ~ ,. t c..'"',Je;e" Pt<u,JosE.u I'\1ING ~-.u-7E h Yl.!rlOEL~::.~-., lu C n;:dJEG i 'PA"'-t 3t... DELTA CREEK NEAR KING CDVE,ALASKA START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ::!:===;-::=== ===== =~=::: ==~:=:::=:::::==~ :=~===!:= :.t:==== :::::===:::= 01/23/85 02:00 2b1 28 1. 40 1. 40 21 01/23/85 04:00 262 28 1. 40 1. 40 21 01/23/85 06: 00 26:3 28 1. 40 1. 40 21 01/23/85 08: 00 264 28 1 40 1. 40 21 01123/85 10: 00 265 28 1. 40 1 40 21 01/23/85 12:00 266 28 1. 40 i. 40 21 RRr~H ,-_-'~~ It~ /' 01/23/85 14:00 267 28 1. 40 1. 40 21 ···:__;~:. 01/23/85 16:00 268 28 1. 40 L 40 21 .......... [.'/.,i, ... 01/23/85 18:00 269 27 1. 35 1. 35 19 01/23/85 20:00 270 27 1. 35 1. 35 19 01/23/85 22:00 271 27 1. 35 1. 35 19 01/23/85 00:00 272 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 38 1. 38 20 01/24/85 02:00 273 27 1. 35 1. 35 19 01/24/85 04:00 274 27 1. 35 1 35 19 01/24/85 06:00 275 27 1. 35 1. 35 19 01/24/85 08:00 276 27 1. 35 1 35 19 01/24/85 10:00 277 27 1. 35 1. 35 19 01/24/85 12:00 278 27 1. 35 1. 35 19 01/24/85 14:00 279 27 1. 35 1. 35 19 01124/85 16: 00 280 27 1. 35 1. 35 19 01/24/85 18:00 281 27 1. 35 1. 35 19 01/24/85 20:00 282 27 1. 35 1. 35 19 01/24/85 22:00 283 27 1. 35 1. 35 19 01/24/85 00:00 284 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 35 1. 35 19 01/2~85 02:00 285 27 1. 35 1. 35 19 011:!' 185 04: 00 286 27 1. 35 1. 35 19 01/25/85 06:00 287 27 1. 35 1. 35 19 01/25/85 08:00 288 27 1. 35 1. 35 19 01/25/85 10:00 289 27 L 35 1. 35 19 01/25/85 12: 00 290 27 1. 35 1. 35 19 01/25/85 14:00 291 27 1. 35 1. 35 19 01/25/85 16:00 292 27 1. 35 1. 35 19 01/25/85 18:00 293 27 1. 35 1. 35 19 01/25/85 20:00 294 27 1. 35 1. 35 19 01/25/85 22:00 295 26 1. 30 1. 30 18 01/25/85 00:00 296 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 35 1. 35 19 i ! 1 ~ I ' PH UP'OSEu "'1 NG Lu.JE 1-n ut<'OELr::.~.-' IU C rrqJJEC. c~. Je;s." PA'..-H 3~ DELTA CREEK NEAR KING COVE,ALASKA START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ========::::: ==:t:t:a:= ===::= :::====:::t::==!'!.':' :=:I!!:I:UIIUII:f» ====== ====== 01/26/85 02:00 297 26 1 30 1. 30 18 01/26/85 04:00 298 27 1. 35 1 35 19 01/26/85 06:00 299 27 1. 35 1. 35 19 01/26/85 08:00 300 27 1. 35 1. 35 19 01/26/85 10:00 301. 27 1. 35 1. 35 19 01/26/85 12:00 302 27 1 35 1. 35 19 01/26/85 14:00 303 27 1. 35 t. 35 19 01/26/85 16:00 304 28 1. 40 1. 40 21 01/26/85 1~:00 305 29 1. 45 1. 45 23 01/26/85 20:00 306 29 1. 45 !. 45 23 01/26/85 22:00 307 28 1. 40 140 21 01/26/85 00:00 308 28 1. 40 i 40 21 DAILY AVERAGE VALUES 1. 38 1. 38 20 01127/85 02:00 309 28 1. 40 1. 40 21 01/27/85 04:00 310 28 1. 40 1. 40 21 01/27/85 06:00 311 28 1. 40 1. 40 21 01/27/85 08:00 312 29 1. 45 1. 45 23 01127/85 10: 00 313 29 L 45 1. 45 23 01127/85 12: 00 314 29 1. 45 1 .. 45 23 Ol/27/85 14:00 315 29 1. 45 1. 45 23 01/27/85 16:00 316 29 1. 45 1. 45 23 01/27/85 18:00 317 29 1. 45 1. 45 23 01/27/85 20:00 318 33 1. 65 1. 65 31 01127/85 22: 00 319 35 1. 75 1. 75 36 01/27/85 00:00 320 35 1. 75 1. 75 36 DAILY AVERAGE VALUES 1. 50 1. 50 25 01/~·85 02:00 321. 34 1. 70 1. 70 34 0112$185 04: 00 322 33 1. 65 1. 65 31 01128/85 06: 00 323 33 1. 65 1. 65 31 01/28/85 08:00 324 32 1. 60 1. 60 29 01/28/85 10:00 325 31 1. 55 1. 55 27 01/28/85 12:00 326 31 1. 55 1. 55 27 01/28/85 14:00 327 30 1. 50 1. 50 25 01/28/85 16:00 328 30 1. 50 1. 50 25 01/28/85 18:00 329 31 1. 55 1. 55 2'7 01/28/85 20:00 330 32 1. 60 1. 60 29 01/28/85 22:00 3;31 34 1. 70 1. 70 34 01/28/85 00:00 332 36 1. 80 1. 80 39 DAILY AVERAQE VALUES L 61 1. 61 30 ;c !' i, ~-' ! I PRO~OSEC• K1ING CO~E HYDROELt.<, I k lC PR~JE(; DELTA CREEK NEAR KING COVE.ALASKA DATE TIME ====:=:::!!:: 01129/85 02: 00 01/29/85 04:00 01/29/85 06:00 01/29/85 08: 00 01/29/85 10:00 01129/85 12: 00 01/29/85 14•00 01/29/85 16:00 01/29/85 18:00 01/29/85 20: 00 01129/85 22: 00 01/29/85 00:00 01/30/85 01130/85 01/30/85 01/30/85 01/30/85 01/30/85 01/30/85 01/30/85 01/30/85 01/30/85 01/30/85 01/30/85 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00 00:00 0113Ji:~S5 02: 00 0113119~ 04:00 01131/85 06:00 01/31/85 08:00 01/31/85 10:00 01/31185 12:00 01/31/85 14:00 01/31185 16:00 01131/85 18:00 01/31/85 20:00 01/31/85 22:00 01/31/85 00:00 BYTE RAW DATA ~~·~:-:: ====:::::==~= 333 41 334 43 335 41 336 39 337 38 3~38 37 339 35 340 35 341 34 342 34 343 33 344 33 DAILY AVERAGE VALUES 345 32 346 32 347 32 348 31 349 31 350 31 351 31 352 31 353 30 354 30 355 30 356 30 DAILY AVERAGE VALUES 357 30 358 30 359 30 360 30 361 32 362 33 363 33 364 33 365 33 366 3:.1 367 32 368 32 DAILY AVERAGE VALUES DEPTH FEET ====== 2. 05 2. 15 2.05 1. 95 1. 90 1. 85 1. 75 1. 75 1. 70 1. 70 1. 65 1. 65 1. 85 1. 60 1. 60 1. 60 1. 55 1. 55 1. 55 1. 55 1. 55 1. 50 1. 50 1. 50 1. 50 1. 55 1. 50 1. 50 1. 50 1. 50 1. 60 1. 65 1. 65 1. 65 1. 65 1. 65 1. 60 1. 60 1. 59 I ' 0~1V8/8~ PA~c . 3b START TIME 10/10/84 02:00 STAGE FEET ======= 205 2. 15 2. 05 1. 95 1. 90 1. 85 1. 75 1. 75 1. 70 1. 70 1. 65 1. 65 1. 85 1. 60 1. 60 1. 60 1. 55 1. 55 1. 55 1. 55 1. 55 1. 50 1. 50 1. 50 1. 50 1. 55 1. 50 1. 50 1. 50 1. 50 1. 60 i. 65 1. 65 1. 65 1. 65 1. 65 1. 60 1. 60 1. 59 DlSCHG CFS ====== 53 59 53 47 44 41 36 36 34 34 31 31 42 29 29 29 27 27 27 27 27 25 25 25 25 27 25 25 25 25 29 31 31 31 31 31 29 29 29 ' Pt<ul"'bSEll 1-\ ~ NG ~.-uJE 1-r r unbELt::.l~ 1 k I C ~-M~JEC Cv< J3/8~ PA\...~. 3'. DELTA CREEK NEAR 11:.ING COVE, ALASI<',A START TIME 10/10/84 02.00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS -·==so:•=!:'! -··=:~ =====-======~::"!:!'= ==·-=-===== ====== 02/01/85 02:00 369 32 1. 60 1. 60 29 02/01/85 04:00 370 32 1. 60 1. 60 29 02/01/85 06:00 371 32 1. 60 1 60 29 02/01/85 08:00 372 32 1. 60 1. 60 29 r'i.\ fj""', '?'" 02/01/85 10·00 373 32 1. 60 L 60 29 02/01185 12:00 374 32 1. 60 1. 60 29 lli n ,~'~ ~; 02/01/85 14:00 375 32 1. 60 1. 60 29 ; : ·:~ c 02/01/85 16:00 376 32 1. 60 1. 60 29 02/01/85 18:00 377 32 1. 60 1 60 29 02/01/85 20:00 378 31 1. 55 1. 55 27 02/01185 22: 00 379 31 1. 55 1. 55 27 02/01/85 00:00 380 31 1. 55 1. 55 27 DAILY AVERAGE VALUES 1. 59 1. 59 29 02/02/85 02:00 381 31 1. 55 1. 55 27 02/02/85 04:00 382 30 1. 50 1. 50 25 02/02/8:5 06:00 383 30 1. 50 1. 50 25 02/02/85 08:00 384 30 1. 50 1. 50 25 02/02/85 10:00 385 30 1. 50 1. 50 25 02/02/85 12:00 386 30 1. 50 1. 50 25 02/02/85 14:00 387 30 1. 50 1. 50 25 02/02/85 16:00 388 29 1. 45 1. 45 23 02/02/85 18:00 389 30 1. 50 1. 50 25 02/02/85 20:00 390 29 1. 45 1. 45 23 02/02/85 22:00 391 29 1. 45 1. 45 23 02/02/85 00:00 392 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 49 1. 49 25 02/0.31:95 02:00 393 29 1. 45 1. 45 23 02/0:3/85 04:00 394 29 1. 45 1. 45 23 02/03/85 06:00 395 29 1. 45 1. 45 23 02/03/85 08:00 396 29 1. 45 1. 45 23 02/03/85 10:00 397 29 1. 45 1. 45 23 02/03/85 12:00 398 29 1. 45 1. 45 23 02/03/85 14:00 399 28 1. 40 1. 40 21 02/03/85 16:00 400 29 1. 45 1. 45 23 02/03/85 18:00 401 29 1 45 1. 45 23 02/03/85 20:00 402 29 1. 45 1. 45 23 02/03/85 22:00 403 29 1. 45 1. 45 23 02/03/85 00:00 404 29 1. 45 1. 45 23 DAIU' AVERAGE VALUES 1. 45 1. 45 23 j i ' f PROPOSED KlNG COVE 1-iYDdOELE<.: r~ IC PROJEC ' {J:J;tl8/8::.> PAbt:. ' 40 DELTA CREEK NEAR KING COVE.ALASKA START TIME 10/i0/84 02.00 DEPTH STAGE DISCHG DATE TIME BY1E RAW DATA FEET FEET CFS ======~= ===:= ==:;.'"!!."! ===::==:-==:=:::.=:: ======= ====== ======::-; 02/04/85 02:00 405 29 1. 45 1. 45 23 02/04/85 04:00 406 29 1. 45 1 45 23 02/04/85 06:00 407 29 1. 45 1. 45 23 02/04/85 08:00 408 29 1. 45 1. 45 23 02/04/85 10:00 409 30 1. 50 1. 50 25 02/04/85 12:00 410 31 1. 55 1. 55 27 02/04/85 14:00 411 30 1. 50 1. 50 25 02/04/85 16:00 412 30 1. 50 1. 50 25 02/04/85 18:00 413 29 1. 45 1. 45 23 02/04/85 20:00 414 30 1 50 1. 50 25 02/04/85 22:00 415 29 1. 45 1. 45 23 02/04/85 00:00 416 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 48 148 24 02/05/85 02:00 417 29 1. 45 1. 45 23 02/05/85 04:00 418 29 1. 45 1. 45 23 02/05/85 06:00 419 28 1. 40 1. 40 21 02/05/85 08:00 420 29 1. 45 1. 45 23 02/05/85 10:00 421 28 1. 40 1. 40 21 02/05/85 12:00 422 29 1. 45 1. 45 23 02/05/85 14:00 423 28 1. 40 1. 40 21 02/05/85 16:00 424 28 1. 40 1. 40 21 02/05/85 18:00 425 28 1. 40 1. 40 21 02/05/85 20:00 426 28 1.40 1. 40 21 02/05/85 22:00 427 28 1. 40 1. 40 21 02/05/85 00:00 428 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 42 1. 42 22 02/04rl95 02:00 429 28 1. 40 1. 40 21 02/061S5 04:00 430 28 1. 40 1. 40 21 02/06/85 06:00 431 28 1. 40 1. 40 21 02/06/85 08:00 432 28 1. 40 1. 40 21 02/06/85 10:00 433 28 1. 40 1. 40 21 02/06/85 12:00 434 28 1. 40 1. 40 21 02/06/85 14:00 435 28 1. 40 1. 40 21 02/06/85 16:00 436 28 1. 40 1. 40 21 02/06/85 18:00 437 28 1. 40 1. 40 21 02/06/85 20:00 438 27 1. 35 1. 35 19 02106/85 22:00 439 2'7 1. 35 1. 35 19 02/06/85 00:00 440 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 39 1. 39 21 ,,I F"._,,bSEL,. {NG ~~•E 1-.• ~JOEL-"".kiC ... JJEC c 13/8 PA( 4j DELTA CREEK NEAR KING COVE.ALASKA START TIME 10/10/84 02.00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ••••••::z~= :a:=~:~:s• ==:.--::=: =====:::::=;.:::::;:t; =====-====== =====:::::= 02/07/85 02:00 441 27 1. 35 L 35 1\i 02/07/85 04.00 442 27 1. 35 1. 35 1\i 02/07/85 06:00 443 27 1. 35 L 35 19 02/07/85 08.00 444 27 1. 35 1. 35 19 02/07/85 10:00 445 2'7 1. 35 L 35 19 02/07/85 12:00 446 27 1. 35 i. 35 19 02/07/85 14:00 447 27 1. 35 1. 35 19 02/07/85 16:00 448 27 1. 35 1 35 19 02/07/85 18·00 449 2'7 1. 35 1. 35 19 02/07/85 20:00 450 27 1. 35 1. 35 19 02/07/85 22:00 451 27 1 35 1. 35 19 02/07/8!'i 00:00 452 27 1. 35 1 35 19 DAILY AVERAGE VALUES 1. 35 1. 35 19 02/08/85 02:00 453 27 1 35 1. 35 19 02/08/85 04:00 454 27 1. 35 1. 35 19 02/08/85 06:00 455 27 1. 35 1 35 19 02/08/85 08:00 456 27 1. 35 1. 35 19 02/08/85 10:00 457 27 1. 35 1. 35 19 02/08/85 12:00 458 27 1. 35 1. 35 19 02/08/85 14:00 459 27 1. 35 1. 35 19 02/08/85 16:00 460 27 1 35 1. 35 19 02/08/85 18:00 461 26 1. 30 1. 30 18 02/08/85 20:00 462 27 1. 35 1 :35 19 02/08/85 22:00 463 26 1. 30 1. 30 18 02/08/85 00:00 464 26 1. 30 1 30 18 DAILY AVERAGE VALUES 1 34 1. 34 19 02/091'95 02:00 465 27 1. 35 1. 35 19 02/09/85 04:00 466 27 1. 35 1. 35 19 02/09/85 06:00 467 27 1. 35 1. 35 19 02/09/85 08:00 468 27 1. 35 1. 35 19 02/09/85 10:00 469 28 1. 40 1. 40 21 02/09/85 12·00 470 28 1. 40 1. 40 21 02/09/85 14:00 471 29 1. 45 1. 45 23 02/09/85 16:00 4"72 28 1. 40 1. 40 21 02/09/85 18:00 473 27 1. 35 1 35 19 02/09/85 20:00 474 26 1. 30 1. 30 18 02/09/85 22:00 475 26 1. 30 1. 30 18 02/09/85 00:00 476 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 35 1. 35 19 ,. 1.· i ~' I 1'.1 F "'-'' irJSE~ "lNG -~ #E 1-. "' ,bEL-_ .inc . JJEC DELTA CREEK NEAR KING COVE,ALASKA DATE TIME =======~ ===== 02/10/85 02:00 02/10/85 04:00 02/10/85 06:00 02/10/85 08:00 02/10/85 10·00 02/10/85 12:00 02/10/85 14:00 02/10/85 16:00 02/10/85 18:00 02/10/85 20:00 02/10/85 22:00 02/10/85 00:00 02/11/8, 02/11/85 02/11/85 02/11/8, 02/11/85 02/11/85 02/11/8, 02/11/85 02/11/85 02/11/85 02/11/85 02/11/85 g;~~~:; 02/12/85 02/12/85 02/12/85 02/12/85 02/12/85 02/12/85 02/12/85 02/12/85 02/12/85 02/12/85 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00 00:00 02:00 04:00 06:00 08:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00 00:00 BYTE RAW DATA ========= 477 25 478 25 479 26 480 26 481 27 482 27 483 27 484 28 485 27 486 27 487 27 488 28 DAILY AVERAGE VALUES 489 28 490 28 491 28 492 29 493 29 494 28 495 29 496 30 497 31 498 31 499 31 500 32 DAILY AVERAGE VALUES 501 33 502 33 503 34 504 35 505 35 506 35 507 35 508 34 509 33 510 33 511 33 512 33 DAILY AVERAGE VALUES DEPTH FEET ====== 1. 25 1. 25 1. 30 1. 30 1. 35 1. 35 1. 35 1. 40 L 35 1. 35 1. 35 1. 40 1. 33 1. 40 1. 40 1. 40 1. 45 1. 45 1. 40 1. 45 L 50 1. 55 1. 55 1. 55 1. 60 1. 48 1 65 1. 65 1. 70 1. 75 1. 75 1. 75 1. 75 1. 70 1. 65 1. 65 1. 65 1. 65 1. 69 C Y3/8 PAl 4~ START TIME 10/10/84 02:00 STAGE FEET ===== 1 25 1 25 1. 30 1. 30 1. 35 1. 35 1. 35 1. 40 1. 35 1. 35 1. 35 1. 40 1. 33 1. 40 1. 40 1. 40 L 45 1. 45 1. 40 1. 45 1. 50 1. 55 1. 55 1. 55 1. 60 1. 48 1 65 1. 65 1. 70 1. 75 1. 75 1. 75 1. 75 i 70 1. 65 1. 65 1. 65 1. 65 1 69 DISCHG CFS =::::::::n::::::::= 16 16 18 18 19 19 19 21 19 19 19 21 19 21 21 21 23 23 21 23 25 27 27 27 29 24 31 31 34 36 36 36 36 34 31 31 31 31 33 F<nurbSEu "lNG ,_,uJE hTurtioEL<--c. .. he r.uJJEC c ... J:ue _ PAc_ 4:... DELTA CREE~ NEAR KING COVE.ALASKA START TIME 10/10/84 02·00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ••==•=== :::•=s= tt::==:=e =====~===:::::. ==::::~==-====== =====~ 02/13/85 02:00 513 32 1. 60 1. 60 29 02/13/85 04:00 514 32 1. 60 1. 60 29 02/13/85 06:00 515 32 1. 60 1. 60 29 02/13/85 08:00 516 32 1. 60 1. 60 29 02/13/85 10:00 51'7 32 1. 60 1. 60 29 02/13/85 12:00 518 31 1. 55 1. 55 27 02/13/85 14:00 519 30 1. 50 1. 50 25 l\ 02/13/85 16·00 520 28 1. 40 1 40 21 02/13/85 18:00 521 25 1. 25 1. 25 16 ') 02/13/85 20:00 522 25 1. 25 1. 25 16' 02/13/85 22:00 523 25 1. 25 1. 25 16 02/13/85 00:00 524 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 45 1. 45 24 02/14/85 02:00 525 25 1. 25 1. 25 16 02/14/85 04:00 526 25 L 25 1. 25 16 02/14/85 06:00 527 25 1. 25 1. 25 16 02/14/85 08:00 528 25 1. 25 1 25 16 02/14/85 10:00 529 25 1 25 1. 25 16 02/14/85 12:00 530 25 1. 25 1. 25 16 02/14/85 14:00 531 25 1. 25 L 25 16 02/14/85 16:00 532 25 1. 25 1. 25 16 02/14/85 18:00 533 25 1. 25 1. 25 16 02/14/85 20:00 534 25 1. 25 1. 25 16 02/14/85 22:00 535 25 1. 25 1. 25 16 02/14/85 00:00 536 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 25 1. 25 16 02/111'85 02:00 537 25 1.25 1. 25 16 02/15185 04:00 538 25 1. 25 1. 25 16 02/15/85 06:00 539 25 1. 25 1. 25 16 02/15/85 08:00 540 25 1. 25 1. 25 16 02/15/85 10:00 541 25 1. 25 1. 25 16 02/15/85 12:00 542 25 1. 25 1. 25 16 02/15/85 14:00 543 25 1 25 1. 25 16 02/15/85 16:00 544 25 1. 25 1. 25 16 02/15/85 18:00 545 25 1. 25 125 16 02/15/85 20:00 546 25 1. 25 1. 25 16 02/15/85 22:00 547 25 1. 25 1. 25 16 02/15/85 00:00 548 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 25 1. 25 16 I Pnut-'bSEu t\ ~ NG ... uJE k • vr-;bELt:.<.. , J11 C r r<JJEC DELTA CREEK NEAR KING COVE,ALASKA DATE TIME ~=r:=====-=== ===== 02/16/85 02:00 02/16/85 04:00 02/16/8~ 06:00 02/16/85 08:00 02/16/85 10:00 02/16/85 12:00 02/16/85 14:00 02/16/85 16:00 02/16/85 18:00 02/16/85 20:00 02/16/85 22:00 02/16/85 00:00 02/17/8~ 02:00 02/17/85 04:00 02/17/85 06:00 02/17/85 08:00 02/17/85 10:00 02/17/85 12:00 02/17/85 14:00 02/17/85 16:00 02/17/85 18:00 02/17/85 20:00 02/17/85 22:00 02/17/85 00:00 02/11iW95 02:00 02/1~!85 04:00 02/18/85 06•00 02/18/85 08:00 02/18/85 10:00 02/18/85 12:00 02/18/85 14:00 02/18/85 16:00 02/18/85 18:00 02/18/85 20:00 02/18/85 22:00 02/18/85 00:00 BYTE RAW DATA ===::-:: ~:!::======= 549 25 550 25 551 25 s;;;;,: 25 553 25 554 25 '555 25 556 25 557 25 558 25 559 25 5~,o 25 DAILY AVERAGE VALUES 561 25 562 25 563 25 564 25 565 25 566 25 567 25 568 25 569 25 570 25 571 25 572 25 DAILY AVERAGE VALUES 573 25 574 25 575 25 576 25 577 24 578 24 579 24 580 24 581 25 582 24 583 25 584 25 DAILY AVERAGE VALUES DEPTH FEET =====:~:= 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 125 1 25 1. 25 1. 25 1 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1 25 1.25 1. 25 L 20 1. 20 1. 20 1. 20 1. 25 1. 20 1. 25 1. 25 1. 23 G.,,'""\:ue .. PAt.~ 4l. START T1 ME 10/10/84 02: 00 STAGE FEET =:::=::!=:::: 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1 25 1. 25 1. 25 1. 25 1. 25 1. 25 1. 25 1 25 1. 25 1. 25 1. 25 1. 25 1 25 1. 25 1. 20 1. 20 1 20 1. 20 1. 25 1. 20 1. 25 1 25 1. 23 DISCHG CFS ===:=== 16 16 16 16 16 16 16 ~~,., .. ,,, 16 16 16 16 16 16 16 16 16 16 16 16 16 16 1b 16 16 16 16 16 16 u;, 16 15 15 15 15 16 15 16 16 16 l i c 1 ! ' PROPOSED KING CO~E HYDROEL~CI~IC ~R0JEC DELTA CREEK NEAR KING COVE,ALAS~A DATE TIME :.::=w==-=!Se~ ==~==~ 02/19/85 02:00 02/19/85 04:00 02/19/85 06:00 02/19/85 08:00 02/19/85 10:00 02/19/85 12:00 02/19/85 14:00 02/19/85 16:00 02/19/85 18:00 02/19/85 20:00 02/19/85 22:00 02/19/85 00:00 02/20/85 02:00 02/20/85 04:00 02/20/85 06:00 02/20/85 08:00 02/20/85 10:00 02/20/85 12:00 02/20/85 14:00 02/20/85 16:00 02/20/85 18:00 02/20/85 20:00 02/20/85 22:00 02/20/85 00:00 02/2lt95 02:00 02/21185 04:00 02/21185 06: 00 02/21/85 08:00 02/21/85 10:00 02/21185 12: 00 02/21/85 14:00 02/21/85 16:00 02/21185 18: 00 02/21185 20: 00 02/21/85 22:00 02/21/85 00:00 BYTE RAW DATA =:::::::::::":':' :r.:::::::::"~=!:l!:~ 585 24 58b 25 587 24 588 24 589 24 590 24 591 24 592 24 s9a 24 594 24 595 24 596 24 DAILY AVERAGE VALUES 597 24 598 24 599 24 600 24 601 24 602 24 603 24 604 24 605 24 606 24 607 24 608 2'l DAILY AVERAGE VALUES 609 24 610 24 611 24 612 24 613 24 614 24 615 24 616 24 617 24 618 24 619 24 620 24 DAILY AVERAGE VALUES DEPTH FEET ====== 1. 20 1. 25 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 0.uv~3i8-> PA\:r<... 1 4::.. START TIME 10/10/84 02:00 STAGE FEET ===~= 1. 20 1. 25 1. 20 1. 20 1 20 1. 20 l.. 20 1. 20 1 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 i. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1.. 20 1. 20 1. 20 1. 20 DISCHG CFS =====t:::= 15 16 15 1 ,-,) 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 '>< ~~ - 11"! : f I< h' F "'-JOSE" "h.tG ,.~IE 1-. ,.JOEL -t;. IC .. __ JE( DELTA CREEK NEAR KING COVL ALAEHf..A DATE TIME ====~=== ===== 02/22/85 02:00 02/22/85 04:00 02/22/85 06:00 02/22/85 08:00 02/22/85 10:00 02/22/8, 12:00 02/22/85 14:00 02/22/85 16:00 02/22/85 18:00 02/22/85 20:00 02/22/85 22:00 02/22/85 00:00 02/23/85 02:00 02/23/85 04:00 02/23/85 Ob:OO 02/23/85 08:00 02/23/85 10:00 02/23/8'5 12:00 02/23/85 14:00 02/23/85 1b·OO 02/23/85 18:00 02/23/8~ 20:00 02/23/85 22:00 02/23/85 00:00 02/2ft85 02:00 o212~ts~ o4:oo 02/24/85 Ob:OO 02/24/85 08:00 02/24/85 10:00 02/24/85 12:00 02/24/85 14:00 02/24/85 16:00 02/24/85 18:00 02/24/85 20:00 02/24/85 22:00 02/24/85 00:00 BYTE RAW DATA ==::='= =::::==:=::::;=:: 621 24 622 24 623 24 624 24 625 24 626 24 627 24 628 24 629 24 630 24 631 24 632 24 DAILY AVERAGE VALUES 633 24 634 24 635 24 636 24 637 24 638 24 639 24 640 24 641 24 642 24 643 24 644 24 DAILY AVERAGE VALUES 645 24 646 24 647 24 648 24 649 24 650 24 651 24 652 24 653 24 654 24 655 24 656 24 DAILY AVERAGE VALUES DEPTH FEET ====== 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 ( BIB PI'>~< 4c START TIME 10/10/84 02· 00 STAGE FEET ====::::::.- 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 i. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1. 20 1 20 1. 20 1. 20 i. 20 1. 20 DISCHG CFS :::;::::=::::::.== 15 15 15 15 15 15 1 r:;e···.R. ~·,; -.·.· '"4 ~ tr· tt \ 15 . &w~ 1! <:; -:'; !{···!? ~ 1~ \ ... \> .. «,;.,. .. f 15 ·... .,"· ·~·. ,, 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 l~' ~ RY ,· r,«-~ A.. ··: :.·.H If.~·. ·~; '~~~-- f._..,, loSE.J .. liNG -~ )E t.. ~.JOEL-~. IC . , jJEC. (. 18/8 PA• 4: DELTA CREEK NEAR KING COVE,ALASKA START TIME 10/10/84 02·00 DEPTH STAGE OISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ::======= ===== ==~~ =====~====-====== ===== =::::::r==:::: 02/25/85 02:00 657 24 1. 20 1. 20 15 02/25/85 04:00 658 24 1. 20 1. 20 15 02/25/85 06:00 659 24 1. 20 1. 20 15 02/25/85 08:00 660 24 1. 20 1. 20 15 02/25/85 10:00 661 24 1. 20 1. 20 15 02/25/85 12:00 662 24 1. 20 1. 20 15 02/25/85 14:00 663 24 1. 20 1 20 15 02/25/85 16:00 664 24 1. 20 1. 20 15 02/25/85 18:00 665 24 1. 20 1 20 15 ARY 02/25/85 20:00 666 24 1. 20 1. 20 15 02/25/85 22:00 667 24 1. 20 1. 20 15 02/25/85 00:00 668 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 20 1. 20 15 02/26/85 02:00 669 24 1. 20 1. 20 15 02/26/85 04:00 670 25 1. 25 1. 25 16 02/26/85 06:00 671 26 1. 30 1. 30 18 02/26/85 08:00 672 26 1. 30 1. 30 18 02/26/85 10:00 673 27 1. 35 1. 35 19 02/26/85 12:00 674 28 1. 40 1. 40 21 02/26/85 14·00 675 28 1' 40 1. 40 21 02/26/85 16:00 676 28 1. 40 1. 40 21 02/26/85 18:00 677 27 1. 35 1 35 19 02/26/85 20:00 678 26 1 30 1. 30 18 02/26/85 22:00 679 26 1. 30 1. 30 18 02/26/85 00:00 680 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 32 1. 32 18 02/2~{:95 02:00 681 25 L 25 1. 25 16 02/21/85 04:00 682 25 1. 25 1. 25 16 02/27/85 06:00 683 25 1. 25 1. 25 1f, 02/27/85 08:00 684 25 1. 25 1. 25 16 02/27/85 10:00 685 25 1. 25 1 25 16 02/27/85 12:00 686 24 1. 20 1. 20 15 02/27/85 14:00 687 25 1. 25 1. 25 16 02/27/85 16:00 688 24 1. 20 1. 20 15 02/27/85 18:00 689 24 1. 20 1. 20 15 02/27/85 20:00 690 24 1. 20 1. 20 15 02/27/85 22:00 691. 24 1. 20 1. 20 15 02/27/85 00:00 692 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 23 1. 23 16 t i r ' r t PROPOSED ~UNG COVE HVDR'OEU:.C t RIC PROJEC O::>i JBte,, PAbt:. 4b DELTA CREEK NEAR KING COVE, AL.ASI<.A START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ::::======== ===== ==== ======::==:::.:::::~ ====== ===== ====== 02/28/85 02:00 693 24 1. 20 1. 20 15 02/28/85 04:00 694 24 1. 20 1. 20 15 02/28/85 06:00 695 24 L 20 L 20 15 02/28/85 08:00 696 24 1. 20 1. 20 15 02/28/85 10:00 697 24 1. 20 1. 20 15 02/28/85 12:00 698 24 1 20 1. 20 15 02/28/85 14:00 699 24 L 20 1 20 15 02/28/85 16:00 700 24 1. 20 1. 20 15 02/28/85 18:00 701 24 1. 20 1. 20 15 02/28/85 20:00 702 24 1. 20 L 20 15 ~ 02/28/85 22:00 703 24 1. 20 1 20 15 02/28/85 00:00 704 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 20 1 20 15 03/01/85 02:00 705 26 1. 30 1. 30 18 03/01185 04: 00 706 29 1. 45 1. 45 23 03/01/85 06:00 707 29 1. 45 1. 45 23 03/01/85 08:00 708 27 1. 35 1. 35 19 03/01/85 10:00 709 27 1. 35 1. 35 19 03/01/85 12:00 710 26 L 30 1. 30 18 03/01/85 14:00 711 26 1. 30 1. 30 18 03/01/85 16:00 712 25 1. 25 1. 25 16 03/01185 18: 00 713 25 1. 25 1. 25 16 03/01/85 20:00 714 25 1. 25 1. 25 16 03/01/85 22:00 715 25 1. 25 1. 25 16 03/01/85 00:00 716 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 31 1. 31 18 03/0Q/95 02:00 717 25 1. 25 1. 25 16 03/02/SS 04:00 718 25 1. 25 1. 25 16 03/02/85 06:00 719 24 1. 20 1. 20 15 03/02/85 08:00 720 25 1. 25 1. 25 16 03/02/85 10:00 721 24 1. 20 1 ::>{} 15 03/02/85 12:00 722 25 1. 25 1 16 03/02/85 14:00 723 24 1. 20 1 15 03/02/85 16:00 724 24 1. 20 1. 20 15 03/02/85 18:00 725 25 1. 25 1. 25 16 03/02/85 20:00 726 24 1. 20 1 20 15 03/02/85 22:00 727 24 1. 20 1. 20 15 l·· 03/02/85 00:00 728 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 22 1. 22 15 I, Pt<u)osEu ,....\NG ~uJE hrJJJOELt:.~.<•hrc rl"\jJEC C~,J8i8_ PAL-4<. DELTA CREEK NEAR KING COVE,ALASKA START TIME 10/10/84 02.00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS •••:m•==· ==•== ::::::::::: ;;=ess:=:::.1:;;;::-====== :::::::::::= ====:::::= 03/03/85 02:00 729 24 1. 20 1. 20 15 03/03/85 04:00 730 24 1. 20 1. 20 15 03/03/85 06:00 731 24 1. 20 1. 20 15 03/03/85 08:00 732 24 1. 20 1 20 15 03/03/85 10:00 733 24 1. 20 1. 20 15 03/03/85 12:00 7;'34 24 1. 20 1. 20 15 03/03/85 14:00 735 24 1. 20 1. 20 15 03/03/85 16:00 736 24 1. 20 1. 20 15 03/03/85 18:00 737 24 1. 20 1. 20 15 03/03/85 20:00 738 24 1. 20 1. 20 15 03/03/85 22:00 739 24 1. 20 i 20 15 03/03/85 00:00 740 24 1. 20 1. 20 15 DAILY AVERAGE VALVES 1. 20 1. 20 15 03/04/85 02:00 741 24 1. 20 1. 20 15 03/04/85 04:00 742 24 1. 20 1. 20 15 03/04/85 06:00 743 24 1. 20 1. 20 15 03/04/85 08:00 744 24 1. 20 i. 20 15 03/04/85 10:00 745 24 1. 20 1. 20 15 03/04/85 12:00 746 24 1 20 1. 20 15 03/04/85 14:00 747 24 1. 20 i. 20 15 03/04/85 16:00 748 24 1. 20 1. 20 15 03/04/85 18:00 749 24 1. 20 1 20 15 03/04/85 20:00 750 25 1. 25 1 25 16 03/04/85 22:00 751 25 1. 25 i. 25 16 03/04/85 00:00 752 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 21 1 21 15 03/0I:IS5 02: oo 753 26 1. 30 1. 30 18 03/05/85 04:00 754 30 1. 50 1. 50 25 03/05/85 06:00 755 34 1. 70 1 70 34 03/05/85 08:00 756 34 1. 70 1. 70 34 03/05/85 10:00 757 34 1. 70 1 70 34 03/05/85 12:00 758 33 1. 65 1. 65 31 03/05/85 14:00 759 34 1. 70 1. 70 34 03/05/85 16:00 760 34 1. 70 1. 70 34 03/05/85 18:00 761 33 1 65 1. 65 31 03/05/85 20:00 762 35 1. 75 1. 75 36 03/05/85 22:00 763 33 1. 65 1. 65 31 03/05/85 00:00 764 32 1. 60 L 60 29 DAILY AVERAGE VALUES 1. 63 1. 63 31 ~ ,; ' " "" ~ 0 .:/\.Js/8" r 5C· PROPbSED K'ING ~;u.JE Hvuk'OELt:.\.H~IC PHUJEC PA(""r,;. DELTA CREEK NEAR KING COVE.ALASKA START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ~~==:!!!~~!l::: ===== ===::;....-:: ===-~=~~:::::'!::"' ======= ::::::=~~= ======= 03/06/85 02:00 765 30 1. 50 1. 50 25 03/06/85 04:00 766 30 1 50 1. 50 25 03/06/85 06:00 767 29 1. 45 1. 45 23 03/06/85 08:00 768 29 1. 45 1. 45 23 03/06/85 10:00 769 29 1. 45 1. 45 23 03/06/85 12:00 770 28 1. 40 1. 40 21 03/06/85 14:00 771. 28 1. 40 1. 40 21 03/06/85 16:00 772 28 1. 40 1. 40 21 03/06/85 18:00 773 27 1. 35 1. 35 19 03/06/85 20:00 774 27 1. 35 1. 35 19 03/06/85 22:00 775 27 1 35 1. 35 19 03/06/85 00:00 776 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 41 1 41 22 -·~~, .,.,., ~-.. r '" .._: >J t 03/07/85 02:00 777 27 1. 35 1. 35 19 03/07/85 04:00 778 27 1. 35 1. 35 19 03/07/85 06:00 779 27 1. 35 1. 35 19 03/07185 08:00 780 26 1. 30 1. 30 18 03/07/BS 10:00 781. 26 1. 30 1. 30 18 03/07/85 12:00 782 26 1. 30 1. 30 18 03/07/85 14:00 783 26 1. 30 1. 30 18 03/07/85 16:00 784 26 1. 30 1. 30 18 03/07/85 18:00 785 27 1. 35 1. 35 19 03/07/85 20:00 786 29 1. 45 1.. 45 23 03/07/85 22:00 787 29 1. 45 1. 45 23 03/07/85 00:00 788 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 35 1. 35 19 03/0iwf.SS 02:00 789 28 1. 40 1. 40 21 03tOE!ttB5 04:oo 790 27 1. 35 1. 35 19 03/08/85 06:00 791 27 1. 35 1. 35 19 03/08/85 08:00 792 27 1. 35 1. 35 19 03/08/85 10:00 793 27 1. 35 1. 35 19 03/08/85 12:00 794 27 1. 35 1. 35 19 03/08/85 14:00 795 27 1. 35 1. 35 19 03/08185 16:00 796 27 1. 35 1. 35 19 03/08185 18:00 797 27 1. 35 1 35 19 03/08185 20:00 798 26 1. 30 L 30 18 03/08/85 22:00 799 26 1. 30 1. 30 18 03/08/85 00:00 800 26 1. 30 1. 30 18 DAILY AVERAGE VALUES 1. 34 1. 34 19 ,,j ! PROPbSED K t NG cu0E ri't' oJoELtt. 1 ~ i C t't\LlJEL ! ' 0'"'1 Ja/I:L· 'PAbc: 5~ DELTA CREEK NEAR KING COVE,ALAHI(A START TIME 10/10/84 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ··====== ====· •==:.: :m=:=s===~::: ======== ====-= ==::::=== 03/09/85 02:00 801 26 1. 30 1. 30 18 03/09/85 04:00 802 26 1. 30 1. 30 18 03/09/85 06:00 803 26 1. 30 1. 30 18 03/09/85 08:00 804 26 1. 30 1. 30 18 03/09/85 10:00 805 26 1. 30 1. 30 18 03/09/85 12:00 806 26 1. 30 1. 30 18 03/09/85 14:00 807 26 1. 30 1. 30 18 03/09/85 16:00 808 26 1. 30 1. 30 18 03/09/85 18:00 809 25 1. 25 1. 25 16 03/09/85 20.00 810 16 0.80 0.80 5.6 03/09/85 22:00 811 17 0.85 0. 85 6. 4 03/09/85 00:00 812 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 20 1. 20 15 03/10/85 02:00 813 25 1. 25 1. 25 16 03/10/85 04:00 814 23 1. 15 1. 15 13 03/10/85 06:00 815 26 1 30 1. 30 18 03/10/85 08:00 816 26 1 30 1. 30 18 03/10/85 10:00 817 27 1. 35 1. 35 19 03/10/85 12:00 818 27 1. 35 1. 35 19 03/10/85 14:00 819 27 1. 35 1. 35 19 03/10/85 16:00 820 27 1. 35 1. 35 19 03/10/85 18:00 821 27 1. 35 1. 35 19 03/10/85 20:00 822 27 1. 35 1. 35 19 03/10/85 22:00 823 27 1. 35 1. 35 19 03/10/85 00:00 824 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 32 1 32 18 0311lci-S5 02: oo 825 27 1. 35 1. 35 19 03/11/85 04:00 826 27 1. 35 1. 35 19 0;3/11/85 06:00 82~1 27 1. 35 1. 35 19 03/11/85 08:00 828 27 1. 35 1. 35 19 03/11185 10:00 829 27 1. 35 1. 35 19 03/11/85 12:00 830 26 1. 30 1 30 18 03/11/85 14: 00 831 26 1 30 1. 30 18 03/11/85 16:00 832 26 1. 30 1. 30 18 03/11/85 18:00 833 26 1. 30 1. 30 18 03/11/85 20:00 834 26 1. 30 1. 30 18 03/11/85 22:00 835 25 1. 25 1. 25 16 03/11/85 00:00 836 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 31 1. 31 18 • PROPOSED KING COVE HYDROELECTRIC PROJEC 05/08/85 PAGE 52 ., DELTA CREEK NEAR KING COVE,ALASKA START TIME 10/10/84 02:00 ., DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ~=!:===!::::: :::::===== :=!::::..""::::-... ==:======= ======= ====== ====:::::= • 03/12/85 02:00 837 25 1. 25 1. 25 16 03/12/85 04:00 838 25 1. 25 1. 25 16 03/12/8~ 06:00 839 25 1. 25 1. 25 16 • 03/12/85 08:00 840 25 1. 25 1. 25 16 03/12/85 10:00 841 25 1. 25 1. 25 16 03/12/85 12:00 842 25 1. 25 1. 25 16 • 03/12/85 14:00 843 25 1. 25 1. 25 16 03/12/85 16:00 844 25 1. 25 1. 25 16 'Oi' ·: r-~ ":: ?' ' ~ ~~ 03/12/8~ 18:00 84!.5 25 1. 2~ 1. 25 16 1.• e'i 03/12/85 20:00 846 25 1. 25 1. 25 16 :.. t. • 03/12/85 22:00 847 24 •• .!':_ ~ 1. 20 1. 20 15 03/12/85 00:00 848 24 1. 20 1. 20 15 • DAILY AVERAGE VALUES 1. 24 1. 24 16 03/13/85 02:00 849 25 1. 2~ 1. 25 16 • 03/13/85 04:00 850 24 1. 20 1. 20 15 03/13/85 06:00 851 24 1. 20 1. 20 15 03/13/85 08:00 852 24 1. 20 1. 20 15 • 03/13/85 10:00 853 25 1. 25 1. 25 16 PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 1 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 .: DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ......... -·--· ----====-·-== ====== -==== ===·== 03/14/85 02:00 1 24 1. 20 1. 20 15 03/14/85 04:00 2 24 1. 20 1. 20 15 03/14/85 06:00 3 24 1. 20 1. 20 15 03/14/85 08:00 4 23 1. 15 1. 15 13 03/14/85 10:00 5 23 1. 15 1. 15 13 03/14/85 12:00 6 24 1. 20 1. 20 15 03/14/85 14:00 7 25 1. 25 1. 25 16 25 -\,... ~1 03/14/85 16:00 8 1. 25 1. 25 16 03/14/85 18:00 9 25 1. 25 1. 25 16 03/14185 20:00 10 25 1. 25 1. 25 16 03/14/85 22:00 11 25 1. 25 1. 25 16 03/14/85 00:00 12 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 22 1. 22 15 03/15/85 02:00 13 26 1. 30 1. 30 18 03/15/85 04:00 14 26 1. 30 1. 30 18 03/15/85 06:00 15 25 1. 25 1. 25 16 03/15/85 08:00 16 24 1. 20 1. 20 15 03/15/85 10:00 17 24 1. 20 1. 20 15 03/15/85 12:00 18 24 1. 20 1. 20 15 03/15/85 14:00 19 24 1. 20 1. 20 15 03/15/85 16:00 20 24 1. 20 1. 20 15 03/15/85 18:00 21 24 1. 20 1. 20 15 03/15/85 20:00 22 24 1. 20 1. 20 15 03/15/85 22:00 23 24 1. 20 1. 20 15 03/15/85 00:00 24 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 22 1. 22 16 03/16/85 02:00 25 24 1. 20 1. 20 15 03/16/85 04:00 26 24 1. 20 1. 20 15 03/16/85 06:00 27 24 1. 20 1. 20 15 03/16/85 08:00 28 24 1. 20 1. 20 15 03/16/85 10:00 29 24 1. 20 1. 20 15 03/16/85 12:00 30 24 1. 20 1. 20 15 03/1b/85 14:00 31 24 1. 20 1. 20 15 03/16/85 16:00 32 24 1. 20 1. 20 15 03/16/85 18:00 33 24 1. 20 1. 20 15 03/16/85 20:00 34 24 1. 20 1. 20 15 03/16/85 22:00 35 25 1. 25 1. 25 16 03/16/85 00:00 36 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 21 1. 21 15 /o< PROPOSED KING COVE HYDROELETRIC PRO~ECT i r 06/24/85 PAGE 2 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ........ -----=··=-====•••:.= ·-==·== ·=··· ==-·== 03/17/85 02:00 37 24 1. 20 1. 20 15 03/17/85 04:00 38 24 1. 20 1. 20 15 03/17/85 06:00 39 24 1. 20 1. 20 15 03/17/85 08:00 40 24 1. 20 1. 20 15 03/17/85 10:00 41 24 1. 20 1. 20 15 03/17/85 12:00 42 23 1. 15 1. 15 13 03/17/85 14:00 43 24 1. 20 1. 20 15 03/17/85 16:00 44 24 1. 20 1. 20 15 03/17/85 18:00 45 24 1. 20 1. 20 15 .. .. 03/17/85 20:00 46 24 l. 20 1. 20 15 03/17/85 22:00 47 24 l. 20 1. 20 15 03/17/85 00:00 48 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 20 1. 20 15 03/18/85 02:00 49 23 1. 15 1. 15 13 03/18/85 04:00 50 23 1. 15 1. 15 13 03/18/85 06:00 51 23 1. 15 1. 15 13 03/18/85 08:00 52 23 1. 15 1. 15 13 03/18/85 10:00 53 23 1. 15 1. 15 13 03/18/85 12:00 54 23 1. 15 1. 15 13 03/18/85 14:00 55 23 1. 15 1. 15 13 03/18/85 16:00 56 23 1. 15 1. 15 13 03/18/85 18:00 57 23 1. 15 1. 15 13 03/18/85 20:00 58 23 1. 15 1. 15 13 03/18/85 22:00 59 23 1. 15 1. 15 13 03/18/85 00:00 60 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. U5 1. 15 13 03/19/85 02:00 61 23 1. 15 1. 15 13 03/19/85 04:00 62 23 1. 15 1. 15 13 03/19/85 06:00 63 23 1. 15 1. 15 13 03/19/85 08:00 64 23 1. 15 1. 15 13 03/19/85 10:00 65 23 1. 15 1. 15 13 03/19/85 12:00 66 23 1. 15 1. 15 13 03/19/85 14:00 67 23 1. 15 1. 15 13 03/19/85 16:00. 68 23 1. 15 1. 15 13 03/19/85 18:00 69 23 1. 15 1. 15 13 03/19/85 20:00 70 23 1. 15 1. 15 13 03/19/85 22:00 71 23 1. 15 1. 15 13 03/19/85 00:00 72 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 15 1. 15 13 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 3 I i : DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =··==··· =·=== ==== ===•===t::= ====== ===== ======= 03/20/85 02:00 73 24 1. 20 1. 20 15 03/20/85 04:00 74 24 1. 20 1. 20 15 03120/85 06:00 75 23 1. 15 1. 15 13 03/20/85 08:00 76 23 1. 15 1. 15 13 ~. II 03/20/85 10:00 77 23 1. 15 1. 15 13 • il 03/20/85 12:00 78 23 1. 15 1. 15 13 03/20/85 14:00 79 23 1. 15 1. 15 13 03/20/85 16:00 80 23 1. 15 1. 15 13 03/20/85 18:00 81 23 1. 15 1. 15 13 03/20/85 20:00 82 23 1. 15 1. 15 13 03/20/85 22:00 83 23 1. 15 1. 15 13 03/20/85 00:00 84 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 16 1. 16 13 03/21/85 02:00 85 22 1. 10 1. 10 12 03/21/85 04:00 86 24 1. 20 1. 20 15 03/21/85 06:00 97 24 1. 20 1. 20 15 03/21/85 08:00 88 25 1. 25 1. 25 16 03/21/85 10:00 89 26 1. 30 1. 30 18 03/21/85 12:00 90 25 1. 25 1. 25 16 03/21/85 14:00 91 25 1. 25 1. 25 16 03/21/85 16:00 92 23 1. 15 1. 15 13 03/21/85 18:00 93 23 1. 15 1. 15 13 03/21/85 20:00 94 23 1. 15 1. 15 13 03/21/85 22:00 95 23 1. 15 1. 15 13 03/21/85 00:00 96 24 1. 20 1. 20 15 DAILY AVERAGE VALUES 1. 20 1. 20 15 03/22/85 02:00 97 25 1. 25 1. 25 16 03/22/85 04:00 98 29 1. 45 1. 45 23 03/22/85 06:00 99 33 1. 65 1. 65 31 03/22/85 08:00 100 38 1. 90 1. 90 44 03/22/85 10:00 101 45 2.25 2.25 66 03/22/85 12:00 102 54 2. 70 2. 70 102 03/22/85 14:00 103 60 3. 00 3.00 131 03/22/85 16:00 104 63 3. 15 3. 15 147 03/22/85 18:00 105 66 3.30 3.30 165 03/22/85 20:00 106 71 3. 55 3. 55 196 03/22/85 22:00 107 74 3. 70 3. 70 217 03/22/85 00:00 108 75 3. 75 3. 75 224 DAILY AVERAGE VALUES 2.64 2. 64 114 ~~! PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 4 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ·-·===== ===·== ==== =======::::= ====== ===·= ======= 03/23/85 02:00 109 75 3. 75 3. 75 224 03/23/85 04:00 110 75 3. 75 3. 75 224 03/23/85 06:00 111 75 3. 75 3. 75 224 03/23/85 08:00 112 78 3.90 3.90 246 03/23/85 10:00 113 76 3.80 3.80 231 03/23/85 12:00 114 75 3. 75 3. 75 224 03/23/85 14:00 115 75 3. 75 3. 75 224 :·' '?f I:. 03/23/85 16:00 116 76 3.80 3.80 231 03/23/85 18:00 117 72 3.60 3.60 203 03/23/85 20:00 118 71 3. 55 3. 55 196 03/23/85 22:00 119 70 3. 50 3. 50 190 03/23/85 00:00 120 69 3.45 3.45 183 DAILY AVERAGE VALUES 3. 70 3. 70 217 03/24/85 02:00 121 69 3.45 3.45 183 03/24/85 04:00 122 67 3. 35 3.35 171 03/24/85 06:00 123 67 3.35 3.35 171 03/24/85 08:00 124 69 3.45 3.45 183 03/24/85 10:00 125 73 3.65 3.65 210 03/24/85 12:00 126 40 2.00 2.00 50 03/24/85 14:00 127 27 l. 35 l. 35 19 03/24/85 16:00 128 23 1. 15 l. 15 13 03/24/85 18:00 129 23 1. 15 1. 15 13 03/24/85 20:00 130 23 1. 15 1. 15 13 03/24/85 22:00 131 23 l. 15 1. 15 13 03/24/85 00:00 132 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 2. 19 2. 19 88 03/25/85 02:00 133 22 1. 10 1. 10 12 03/25/85 04:00 134 22 1. 10 1. 10 12 03/25/85 06:00 135 22 1. 10 1. 10 12 03/25/85 08:00 136 23 1. 15 1. 15 13 03/25/85 10:00 137 22 1. 10 l. 10 12 03/25/85 12:00 138 22 1. 10 1. 10 12 03/25/85 14:00 139 23 l. 15 1. 15 13 03/25/85 16:00 140 22 1. 10 1. 10 12 03/25/85 18:00 141 22 1. 10 l. 10 12 03/25/85 20:00 142 22 1. 10 1. 10 12 03/25/85 22:00 143 22 1. 10 1. 10 12 03/25/85 00:00 144 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 11 1.11 12 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 5 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS -·-·=·-== =••== ·=·= ============ ·====· ===== ====== 03/26/85 02:00 145 22 1. 10 1. 10 12 03/26/85 04:00 146 22 1. 10 1. 10 12 03/26/85 06:00 147 22 1. 10 1. 10 12 03/26/85 08:00 148 22 1. 10 1. 10 12 03/26/85 10:00 149 22 1. 10 1. 10 12 03/26/85 12:00 150 22 1. 10 1. 10 12 -.. :-.,; 03/26/85 14:00 151 22 1. 10 1. 10 12 03/26/85 16:00 152 22 1. 10 1. 10 12 03/26/85 18:00 153 22 1. 10 1. 10 12 03/26/85 20:00 154 22 1. 10 1. 10 12 03/26/85 22:00 155 22 1. 10 1. 10 12 03/26/85 00:00 156 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 03/27/85 02:00 157 22 1. 10 1. 10 12 03/27/85 04:00 158 22 1. 10 1. 10 12 03/27/85 06:00 159 22 1. 10 1. 10 12 03/27/85 08:00 160 22 1. 10 1. 10 12 03/27/85 10:00 161 22 1. 10 1. 10 12 03/27/85 12:00 162 22 1. 10 1. 10 12 03/27/85 14:00 163 22 1. 10 1. 10 12 03/27/85 16:00 164 22 1. 10 1. 10 12 03/27/85 18:00 165 22 1. 10 1. 10 12 03/27/85 20:00 166 22 1. 10 1. 10 12 03/27/85 22:00 167 22 1. 10 1. 10 12 03/27/85 00:00 168 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 03/28/85 02:00 169 22 1. 10 1. 10 12 03/28/85 04:00 170 22 1. 10 1. 10 12 03/28/85 06:00 171 22 1. 10 1. 10 12 03/28/85 08:00 172 22 1. 10 1. 10 12 03/28/85 10:00 173 22 1. 10 1. 10 12 03/28/85 12:00 174 22 1. 10 1. 10 12 03/28/85 14:00 175 22 1. 10 1. 10 12 03/28/85 16:00 176 22 1. 10 1. 10 12 03/28/85 18:00 177 22 1. 10 1. 10 12 03/28/85 20:00 178 22 1. 10 1. 10 12 03/28/85 22:00 179 22 1. 10 1. 10 12 03/28/85 00:00 180 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 6 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ····==== =·=== ==== ============ ======== ===== ====== 03/29/85 02:00 181 22 1. 10 1. 10 12 03/29/85 04:00 182 22 1. 10 1. 10 12 03/29/85 06:00 183 22 1. 10 1. 10 12 03/29/85 08:00 184 22 1. 10 1. 10 12 '7 t' ~·. ~ ' ·. 03/29/85 10:00 185 22 1. 10 1. 10 12 03/29/85 12:00 186 22 1. 10 1. 10 12 03/29/85 14:00 187 22 1. 10 1. 10 12 03/29/85 16:00 188 22 1. 10 1. 10 12 03/29/85 18:00 189 22 1. 10 1. 10 12 03/29/85 20:00 190 22 1. 10 1. 10 12 03/29/85 22:00 191 22 1. 10 1. 10 12 03/29/85 00:00 192 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 03/30/85 02:00 193 22 1. 10 1. 10 12 03/30/85 04:00 194 22 1. 10 1. 10 12 03/30/85 06:00 195 22 1. 10 1. 10 12 03/30/85 08:00 196 22 1. 10 1. 10 12 03/30/85 10:00 197 22 1. 10 1. 10 12 03/30/85 12:00 198 22 1. 10 1. 10 12 03/30/85 14:00 199 22 1. 10 1. 10 12 03/30/85 16:00 200 22 1. 10 1. 10 12 03/30/85 18:00 201 22 1. 10 1. 10 12 03/30/85 20:00 202 22 1. 10 1. 10 12 03/30/85 22:00 203 22 1. 10 1. 10 12 03/30/85 00:00 204 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 10 1. 10 12 03/31/85 02:00 205 23 1. 15 1. 15 13 03/31/85 04:00 206 22 1. 10 1. 10 12 03/31185 06: 00 207 22 1. 10 1. 10 12 03/31/85 08:00 208 22 1. 10 1. 10 12 03/31/85 10:00 209 22 1. 10 1. 10 12 03/31/85 12:00 210 22 1. 10 1. 10 12 03/31/85 14:00 211 22 1. 10 1. 10 12 03/31/85 16:00 212 22 1. 10 1. 10 12 03/31/85 18:00 213 22 1. 10 1. 10 12 03/31/85 20:00 214 22 1. 10 1. 10 12 03/31/85 22:00 215 22 1. 10 1. 10 12 03/31/85 00:00 216 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 7 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TII"IE BYTE RAW DATA FEET FEET CFS ==··==== ===== ==·= ========== ====== ===== ====== 04/01/85 02:00 217 22 1. 10 1. 10 12 04/01/85 04:00 218 22 1. 10 1. 10 12 04/01/85 06:00 219 22 1. 10 1. 10 12 04/01/85 08:00 220 22 1. 10 1. 10 12 :r ,i ~ .. ~ Jr r~ 04/01/85 10:00 221 22 1. 10 1. 10 12 04/01/85 12:00 222 22 1. 10 1. 10 12 04/01/85 14:00 223 22 1. 10 1. 10 12 04/01/85 16:00 224 22 1. 10 1. 10 12 04/01/85 18:00 225 22 1. 10 1. 10 12 04/01/85 20:00 226 22 1. 10 1. 10 12 04/01/85 22:00 227 22 1. 10 1. 10 12 04/01/85 00:00 228 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 04/02/85 02:00 229 22 1. 10 1. 10 12 04/02/85 04:00 230 22 1. 10 1. 10 12 04/02/85 06:00 231 22 1. 10 1. 10 12 04/02/85 08:00 232 22 1. 10 1. 10 12 04/02/85 10:00 233 22 1. 10 1. 10 12 04/02/85 12:00 234 22 1. 10 1. 10 12 04/02/85 14:00 235 22 1. 10 1. 10 12 04/02/85 16:00 236 22 1. 10 1. 10 12 04/02/85 18:00 237 22 1. 10 1. 10 12 04/02/85 20:00 238 22 1. 10 1. 10 12 04/02/85 22:00 239 22 1. 10 1. 10 12 04/02/85 00:00 240 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 04/03/85 02:00 241 22 1. 10 1. 10 12 04/03/85 04:00 242 22 1. 10 1. 10 12 04/03/85 06:00 243 22 1. 10 1. 10 12 04/03/85 08:00 244 22 1. 10 1. 10 12 04/03/85 10:00 245 22 1. 10 1. 10 12 04/03/85 12:00 246 22 1. 10 1. 10 12 04/03/85 14:00 247 22 1. 10 1. 10 12 04/03/85 16:00· 248 22 1. 10 1. 10 12 04/03/85 18:00 249 22 1. 10 1. 10 12 04/03/85 20:00 250 22 1. 10 1. 10 12 04/03/85 22:00 251 22 1. 10 1. 10 12 04/03/85 00:00 252 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 '" ' ~ PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 8 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS •=z===== ==•== ·==== ========= ======= ====== ====== 04/04/85 02:00 253 22 1. 10 1. 10 12 04/04/85 04:00 254 22 1. 10 1. 10 12 04/04/85 06:00 255 22 1. 10 1. 10 12 04/04/85 08:00 256 22 1. 10 1. 10 12 i•' , .. !• ¥,J 04/04/85 10:00 257 22 1. 10 1. 10 12 : ·~ . 04/04/85 12:00 258 22 1. 10 1. 10 12 04/04/85 14:00 259 22 1. 10 1. 10 12 _..::-.4~~!~ ?. 04/04/85 16:00 260 22 1. 10 1. 10 12 04/04/85 18:00 261 22 1. 10 1. 10 12 04/04/85 20:00 262 22 1. 10 1. 10 12 04/04/85 22:00 263 22 1. 10 1. 10 12 04/04/85 00:00 264 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 04/05/85 02:00 265 22 1. 10 1. 10 12 04/05/85 04:00 266 22 1. 10 1. 10 12 04/05/85 06:00 267 22 1. 10 1. 10 12 04/05/85 08:00 268 22 1. 10 1. 10 12 04/05/85 10:00 269 22 1. 10 1. 10 12 04/05/85 12:00 270 22 1. 10 1. 10 12 04/05/85 14:00 271 22 1. 10 1. 10 12 04/05/85 16:00 272 22 1. 10 1. 10 12 04/05/85 18:00 273 22 1. 10 1. 10 12 04/05/85 20:00 274 22 1. 10 1. 10 12 04/05/85 22:00 275 22 1. 10 1. 10 12 04/05/85 00:00 276 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1 10 1. 10 12 04/06/85 02:00 277 22 1. 10 1. 10 12 04/06/85 04:00 278 22 1. 10 1. 10 12 04/06/85 06:00 279 22 1. 10 1. 10 12 04/06/85 08:00 280 22 1. 10 1. 10 12 04/06/85 10:00 281 22 1. 10 1. 10 12 04/06/85 12:00 282 22 1. 10 1. 10 12 04/06/85 14:00 283 22 1. 10 1. 10 12 04/06/85 16:00 284 22 1. 10 1. 10 12 04/06/85 18:00 285 22 1. 10 1. 10 12 04/06/85 20:00 286 22 1. 10 1. 10 12 04/06/85 22:00 287 22 1. 10 1. 10 12 04/06/85 00:00 288 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 9 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ======== ====== =·=== ========= ====== ===== ====== 04/07/85 02:00 289 22 1. 10 . 1. 10 12 04/07/85 04:00 290 22 1. 10 1. 10 12 04/07/85 06:00 291 22 1. 10 1. 10 12 04/07/85 08:00 292 22 1. 10 1. 10 12 ·~ . 04/07/8S 10:00 293 22 1. 10 1. 10 12 P' 04/07/8S 12:00 294 22 1. 10 1. 10 12 04/07/8S 14:00 29S 22 1. 10 1. 10 12 04/07/8S 16:00 296 22 1. 10 1. 10 12 04/07/8S 18:00 297 22 1. 10 1. 10 12 04/07/85 20:00 298 22 1. 10 1. 10 12 04/07/85 22:00 299 22 1. 10 1. 10 12 04/07/85 00:00 300 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 04/08/8S 02:00 301 22 1. 10 1. 10 12 04/08/85 04:00 302 22 1. 10 1. 10 12 04/08/85 06:00 303 22 1. 10 1. 10 12 04/08/85 08:00 304 22 1. 10 1. 10 12 04/08/85 10:00 305 21 1. 05 1. 05 11 04/08/85 12:00 306 21 1. 05 1. OS 11 04/08/85 14:00 307 21 1. 05 1. 05 11 04/08/85 16:00 308 22 1. 10 1. 10 12 04/08/85 18:00 309 22 1. 10 1. 10 12 04/08/85 20:00 310 22 1. 10 1. 10 12 04/08/85 22:00 311 22 1. 10 1. 10 12 04/08/8S 00:00 312 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 09 1. 09 12 04/09/8S 02:00 313 21 1. OS 1. 05 11 04/09/85 04:00 314 21 1. 05 1. OS 11 04/09/85 06:00 315 22 1. 10 1. 10 12 04/09/85 08:00 316 22 1. 10 1. 10 12 04/09/8S 10:00 317 21 1. 05 1. OS 11 04/09/85 12:00 318 21 1. 05 1. 05 11 04/09/8S 14:00 319 21 1. 05 1 05 11 04/09/85 16:00 320 21 1. 05 1. 05 11 04/09/85 18:00 321 21 1. 05 1. 05 11 04/09/85 20:00 322 22 1. 10 1. 10 12 04/09/85 22:00 323 22 1. 10 1. 10 12 04/09/85 00:00 324 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 07 1. 07 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/8!5 PAGE 10 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ====•=== ·==== ==== ========== ====== ======= ====== 04/10/85 02:00 325 22 1. 10 1. 10 12 04/10/85 04:00 326 22 1. 10 1. 10 12 04/10/85 06:00 327 21 1. 05 1. 05 11 04/10/85 08:00 328 21 1. 05 1. 05 11 04/10/85 10:00 329 21 1. 05 1. 05 11 04/10/85 12:00 330 21 1. 05 1. 0!5 11 04/10/85 14:00 331 21 1. 05 1. 05 11 04/10/85 16:00 332 21 1. 05 1. 05 11 ~' 04/10/85 18:00 333 22 1. 10 1. 10 12 04/10/85 20:00 334 22 1. 10 1. 10 12 04/10/85 22:00 335 21 1. 05 1. 05 11 04/10/85 00:00 336 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 07 1. 07 11 04/11/85 02:00 337 21 1. 05 1. 05 11 04/11/85 04:00 338 22 1. 10 1. 10 12 04/11/85 06:00 339 22 1. 10 1. 10 12 04/11/85 08:00 340 22 1. 10 1. 10 12 04/11/85 10: 00 341 22 1. 10 1. 10 12 04/11/85 12:00 342 22 1. 10 1. 10 12 04/11/85 14:00 343 22 1. 10 1. 10 12 04/11/85 16:00 344 21 1. 05 1. 05 11 04/11/85 18: 00 345 22 1. 10 1. 10 12 04/11/85 20:00 346 22 1. 10 1. 10 12 04/11/85 22:00 347 22 1. 10 1. 10 12 04/11/85 00:00 348 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 09 1. 09 12 04/12/85 02:00 349 22 1. 10 1. 10 12 04/12/85 04:00 350 21 1. 05 1. 05 11 04/12/85 06:00 351 22 1. 10 1. 10 12 04/12/85 08:00 352 22 1. 10 1. 10 12 04/12/85 10:00 353 22 1. 10 1. 10 12 04/12/85 12:00 354 22 1. 10 1. 10 12 04/12/85 14:00 355 22 1. 10 1. 10 12 04/12/85 16:00 356 22 1. 10 1. 10 12 04/12/85 18:00 357 22 1. 10 1. 10 12 04/12/85 20:00 358 22 1. 10 1. 10 12 04/12/85 22:00 359 21 1. 05 1. 05 11 04/12/8!5 00:00 360 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 09 1. 09 12 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 11 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ======== ===== ==·= ========= ====== ====ua ====== 04/13/85 02:00 361 22 1. 10 1. 10 12 04/13/85 04:00 362 21 1. 05 1. 05 11 04/13/85 06:00 363 21 1. 05 1. 05 11 04/13/85 08:00 364 21 1. 05 1. 05 11 04/13/85 10:00 365 22 1. 10 1. 10 12 04/13/85 12:00 366 21 1. 05 1. 05 11 04/13/85 14:00 367 21 1. 05 1. 05 11 04/13/85 16:00 368 21 1. 05 1. 05 11 04/13/85 18:00 369 22 1. 10 1. 10 12 04/13/85 20:00 370 21 1. 05 1. 05 11 04/13/85 22:00 371 21 1. 05 1. 05 11 04/13/85 00:00 372 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 06 1. 06 11 04/14/85 02:00 373 21 1. 05 1. 05 11 04/14/85 04:00 374 21 1. 05 1. 05 11 04/14/85 06:00 375 21 1. 05 1. 05 11 04/14/85 08:00 376 21 1. 05 1. 05 11 04/14/85 10:00 377 21 1. 05 1. 05 11 04/14/85 12:00 378 22 1. 10 1. 10 12 04/14/85 14:00 379 23 1. 15 1. 15 13 04/14/85 16:00 380 23 1. 15 1. 15 13 04/14/85 18:00 381 24 1. 20 1. 20 15 04/14/85 20:00 382 24 1. 20 1. 20 15 04/14/85 22:00 383 24 1. 20 1. 20 15 04/14/85 00:00 384 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 12 1. 12 13 04/15/85 02:00 385 21 1. 05 1. 05 11 04/15/85 04:00 386 21 1. 05 1. 05 11 04/15/85 06:00 387 21 1. 05 1. 05 11 04/15/85 08:00 388 21 1. 05 1. 05 11 04/15/85 10:00 389 21 1. 05 1. 05 11 04/15/85 12:00 390 21 1. 05 1. 05 11 04/15/85 14:00 391 21 1. 05 1. 05 11 04/15/85 16:00 392 21 1. 05 1. 05 11 04/15/85 18:00 393 21 1. 05 1. 05 11 04/15/85 20:00 394 21 1. 05 1. 05 11 04/15/85 22:00 395 21 1. 05 1. 05 11 04/15/85 00:00 396 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 12 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =====··= ==·== =·=· ========= ====::::::= ===== ====== 04/16/85 02:00 397 21 1. 05 1. 05 11 04/16/85 04:00 398 21 1. 05 1. 05 11 04/16/85 06:00 399 21 1. 05 1. 05 11 ' -~~ ~ ~ -~ ;i~" ,:i ~~;') ~~-~' 04/16/85 08:00 400 21 1. 05 1. 05 11 04/16/85 10:00 401 21 1. 05 1. 05 11 04/16/85 12:00 402 21 1. 05 1. 05 11 04/16/85 14:00 403 21 1. 05 1. 05 11 04/16/85 16:00 404 21 1. 05 1. 05 11 04/16/85 18:00 405 23 1. 15 1. 15 13 04/16/85 20:00 406 29 1. 45 1. 45 23 04/16/85 22:00 407 44 2.20 2.20 63 04/16/85 00:00 408 49 2.45 2.45 81 DAILY AVERAGE VALUES 1. 30 1. 30 22 04/17/85 02:00 409 48 2. 40 2.40 77 04/17/85 04:00 410 51 2. 55 2. 55 89 04/17/85 06:00 411 32 1. 60 1. 60 29 04/17/85 08:00 412 21 1. 05 1. 05 11 04/17/85 10:00 413 21 1. 05 1. 05 11 04/17/85 12:00 414 21 1. 05 1. 05 11 04/17/85 14:00 415 21 1. 05 1. 05 11 04/17/85 16:00 416 21 1. 05 1. 05 11 04/17/85 18:00 417 21 1. 05 1. 05 11 04/17/85 20:00 418 21 1. 05 1. 05 11 04/17/85 22:00 419 21 1. 05 1. 05 11 04/17/85 00:00 420 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 33 1. 33 25 04/18/85 02:00 421 21 1. 05 1. 05 11 -04/18/85 04:00 422 21 1. 05 1. 05 11 04/18/85 06:00 423 21 1. 05 1. 05 11 04/18/85 08:00 424 21 1. 05 1. 05 11 04/18/85 10:00 425 21 1. 05 1. 05 11 04/18/85 12:00 426 21 1. 05 1. 05 11 04/18/85 14:00 427 21 1. 05 1. 05 11 04/18/85 16:00. 428 21 1. 05 1. 05 11 04/18/85 18:00 429 21 1. 05 1. 05 11 04/18/85 20:00 430 21 1. 05 1. 05 11 04/18/85 22:00 431 21 1. 05 1. 05 11 04/18/85 00:00 432 21 1. 05 1 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 13 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ··====== ==·== ==== =====·==== ====•==r= ===== ==:::t:=== 04/19/85 02:00 433 21 1. 05 1. 05 11 04/19/85 04:00 434 21 1. 05 1. 05 11 04/19/85 06:00 435 21 1. 05 1. 05 11 04/19/85 08:00 436 21 1. 05 1. 05 11 04/19/85 10:00 437 ·21 1. 05 1. 05 11 04/19/85 12:00 438 21 1. 05 1. 05 11 04/19/85 14:00 439 21 1. 05 1. 05 11 04/19/85 16:00 440 21 1. 05 1. 05 11 04/19/85 18:00 441 21 1. 05 1. 05 11 04/19/85 20:00 442 21 1. 05 1. 05 11 04/19/85 22:00 443 21 1. 05 1. 05 11 04/19/85 00:00 444 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 04/20/85 02:00 445 21 1. 05 1. 05 11 04/20/85 04:00 446 21 1. 05 1. 05 11 04/20/85 06:00 447 21 1. 05 1. 05 11 04/20/85 08:00 448 21 1. 05 1. 05 11 04/20/85 10:00 449 21 1. 05 1. 05 11 04/20/85 12:00 450 21 1. 05 1. 05 11 04/20/85 14:00 451 21 1. 05 1. 05 11 04/20/85 16:00 452 21 1. 05 1. 05 11 04/20/85 18:00 453 21 1. 05 1. 05 11 04/20/85 20:00 454 21 1. 05 1. 05 11 04/20/85 22:00 455 21 1. 05 1 05 11 04/20/85 00:00 456 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 04/21/85 02:00 457 21 1. 05 1. 05 11 04/21/85 04:00 458 21 1. 05 1. 05 11 04/21/85 06:00 459 21 1. 05 1. 05 11 04/21/85 08:00 460 21 1. 05 1. 05 11 04/21/85 10:00 461 21 1. 05 1. 05 11 04/21/85 12:00 462 21 1. 05 1. 05 11 04/21/85 14:00 463 21 1. 05 1. 05 11 04/21/85 16:00 464 21 1. 05 1. 05 11 04/21/85 18:00 465 21 1. 05 1. 05 11 04/21/85 20:00 466 21 1. 05 1. 05 11 04/21/85 22:00 467 21 1. 05 1. 05 11 04/21/85 00:00 468 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 14 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =======· ====== ==== =====·=== ====== ·=-== ====== 04/22/85 02:00 469 21 1. 05 1. 05 11 04/22/85 04:00 470 21 1. 05 1. 05 11 04/22/85 06:00 471 21 1. 05 1. 05 11 ' Jf :; •. ' l! 04/22/85 08:00 472 21 1. 05 1. 05 11 04/22/85 10:00 473 21 1. 05 1. 05 11 04/22/85 12:00 474 21 1. 05 1. 05 11 04/22/85 14:00 475 21 1. 05 1. 05 11 04/22/85 16:00 476 21 1. 05 1. 05 11 04/22/85 18:00 477 21 1. 05 1. 05 11 04/22/85 20:00 478 21 1. 05 1. 05 11 04/22/85 22:00 479 21 1. 05 1. 05 11 04/22/85 00:00 480 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 04/23/85 02:00 481 21 1. 05 1. 05 11 04/23/85 04:00 482 21 1. 05 1. 05 11 04/23/85 06:00 483 21 1. 05 1. 05 11 04/23/85 08:00 484 21 1. 05 1. 05 11 04/23/85 10:00 485 21 1. 05 1. 05 11 04/23/85 12:00 486 21 1. 05 1. 05 11 04/23/85 14:00 487 21 1. 05 1. 05 11 04/23/85 16:00 488 21 1. 05 1. 05 11 04/23/85 18:00 489 21 1. 05 1. 05 11 04/23/85 20:00 490 21 1. 05 1. 05 11 04/23/85 22:00 491 21 1. 05 1. 05 11 04/23/85 00:00 492 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 04/24/85 02:00 493 21 1. 05 1. 05 11 -04/24/85 04:00 494 21 1. 05 1. 05 11 04/24/85 06:00 495 21 1. 05 1. 05 11 04/24/85 08:00 496 21 1. 05 1. 05 11 04/24/85 10:00 497 21 1. 05 1. 05 11 04/24/85 12:00 498 21 1. 05 1. 05 11 04/24/85 14:00 499 21 1. 05 1. 05 11 04/24/85 16:00 500 21 1. 05 1. 05 11 04/24/85 18:00 501 21 1. 05 1. 05 11 04/24/85 20:00 502 21 1. 05 1. 05 11 04/24/85 22:00 503 21 1. 05 1. 05 11 04/24/85 00:00 504 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 15 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ===··=== ====== ==== ========== ======= ===== ====== 04/25/85 02:00 505 21 1. 05 1. 05 11 04/25/85 04:00 506 21 1. 05 1. 05 11 : 04/25/85 06:00 507 21 1. 05 1. 05 11 \t 04/25/85 08:00 508 21 1. 05 1. 05 11 04/25/85 10:00 509 20 1. 00 1. 00 9. 5 04/25/85 12:00 510 21 1. 05 1. 05 11 04/25/85 14:00 511 21 1. 05 1. 05 11 04/25/85 16:00 512 21 1. 05 1. 05 11 04/25/85 18:00 513 21 1. 05 1. 05 11 04/25/85 20:00 514 21 1. 05 1. 05 11 04/25/85 22:00 515 21 1. 05 1. 05 11 04/25/85 00:00 516 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 04/26/85 02:00 517 21 1. 05 1. 05 11 04/26/85 04:00 518 52 2. 60 2. 60 93 04/26/85 06:00 519 62 3. 10 3. 10 142 04/26/85 08:00 520 63 3. 15 3. 15 147 04/26/85 10:00 521 57 2.85 2.85 116 04/26/85 12:00 522 26 1. 30 1. 30 18 04/26/85 14:00 523 20 1. 00 1. 00 9. 5 04/26/85 16:00 524 21 1. 05 1. 05 11 04/26/85 18:00 525 20 1. 00 1. 00 9. 5 04/26/85 20:00 526 29 1. 45 1. 45 23 04/26/85 22:00 527 33 1 65 1. 65 31 04/26/85 00:00 528 46 2. 30 2. 30 70 DAILY AVERAGE VALUES 1. 88 1. 88 57 04/27/85 02:00 529 56 2. 80 2.80 111 04/27/85 04:00 530 61 3.05 3.05 137 04/27/85 06:00 531 61 3. 05 3.05 137 04/27/85 08:00 532 62 3. 10 3. 10 142 04/27/85 10:00 533 61 3. 05 3.05 137 04/27/85 12:00 534 60 3. 00 3.00 131 04/27/85 14:00 535 60 3. 00 3.00 131 04/27/85 16:00 536 47 2. 35 2.35 73 04/27/85 18:00 537 25 1. 25 1. 25 16 04/27/85 20:00 538 21 1. 05 1. 05 11 04/27185 22:00 539 21 1. 05 1. 05 11 04/27/85 00:00 540 20 1. 00 1. 00 9. 5 DAILY AVERAGE VALUES 2. 31 2.31 87 PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 16 DELTA CREEK NEAR KING COVE• ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ==·==·=== ===== ==== ========= ====== ====== ====== 04/28/85 02:00 541 20 1. 00 1. 00 9. 5 04/28/85 04:00 542 20 1. 00 1. 00 9. 5 04/28/85 06:00 543 21 1. 05 1. 05 11 04/28/85 08:00 544 20 1. 00 1. 00 9. 5 . 't 04/28/85 10:00 545 21 1. 05 1. 05 11 04/28/85 12:00 546 21 1. 05 1. 05 11 04/28/85 14:00 547 20 1. 00 1. 00 9. 5 04/28/85 16:00 548 21 1. 05 1. 05 11 04/28/85 18:00 549 21 1. 05 1. 05 11 04/28/85 20:00 :550 21 1. 05 1. 05 11 04/28/85 22:00 551 20 1. 00 1. 00 9. 5 04/28/85 00:00 552 20 1. 00 1. 00 9. 5 DAILY AVERAGE VALUES 1. 03 1. 03 10 04/29/85 02:00 553 20 1. 00 1. 00 9. 5 04/29/85 04:00 554 20 1. 00 1. 00 9. 5 04/29/85 06:00 555 21 1. 05 1. 05 11 04/29/85 08:00 556 20 1. 00 1. 00 9. 5 04/29/85 10:00 557 20 1. 00 1. 00 9. 5 04/29/85 12:00 558 20 1. 00 1. 00 9. 5 04/29/85 14:00 559 21 1. 05 1. 05 11 04/29/85 16:00 560 20 1. 00 1. 00 9. 5 04/29/85 18:00 561 20 1. 00 1. 00 9. 5 04/29/85 20:00 562 20 1. 00 1. 00 9. 5 04/29/85 22:00 563 20 1. 00 1. 00 9. 5 04/29/85 00:00 564 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 01 1. 01 9.9 04/30/85 02:00 565 20 1. 00 1. 00 9. 5 04/30/85 04:00 566 20 1. 00 1. 00 9. 5 04/30/85 06:00 567 21 1. 05 1. 05 11 04/30/85 08:00 568 23 1. 15 1. 15 13 04/30/85 10:00 569 25 1. 25 1. 25 16 04/30/85 12:00 570 24 1. 20 1. 20 15 04/30/85 14:00 571 22 1. 10 1. 10 12 04/30/85 16:00 572 20 1. 00 1. 00 9. 5 04/30/85 18:00 573 20 1. 00 1. 00 9. 5 04/30/85 20:00 574 20 1. 00 1. 00 9. 5 04/30/85 22:00 575 21 1. 05 1. 05 11 04/30/85 00:00 576 20 1. 00 1. 00 9. 5 DAILY AVERAGE VALUES 1. 07 1. 07 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 17 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ====·=== ====== ==== ========= ====== ===== ====== 05/01/85 02:00 577 21 1. 05 1. 05 11 05/01/85 04:00 578 20 1. 00 1. 00 9. 5 05/01/85 06:00 579 21 1. 05 1. 05 11 05/01/85 08:00 580 20 1. 00 1. 00 9. 5 05/01/85 10:00 581 20 1. 00 1. 00 9. 5 05/01/85 12:00 582 20 1. 00 1. 00 9. 5 05/01/85 14:00 583 20 1. 00 1. 00 9. 5 ; . 05/01/85 16:00 584 20 1. 00 1. 00 9. 5 05/01/85 18:00 585 20 1. 00 1. 00 9. 5 05/01/85 20:00 586 20 1. 00 1. 00 9. 5 05/01/85 22:00 587 20 1. 00 1. 00 9. 5 05/01/85 00:00 588 20 1. 00 1. 00 9. 5 DAILY AVERAGE VALUES 1. 01 1. 01 9. 8 05/02/85 02:00 589 20 1. 00 1. 00 9. 5 05/02/85 04:00 590 20 1. 00 1. 00 9. 5 05/02/85 06:00 591 21 1. 05 1. 05 11 05/02/85 08:00 592 20 1. 00 1. 00 9. 5 05/02/85 10:00 593 20 1. 00 1. 00 9. 5 05/02/85 12:00 594 21 1. 05 1. 05 11 05/02/85 14:00 595 21 1. 05 1. 05 11 05/02/85 16:00 596 21 1. 05 1. 05 11 05/02/85 18:00 597 21 1. 05 1. 05 11 05/02/85 20:00 598 22 1. 10 1. 10 12 05/02/85 22:00 599 21 1. 05 1. 05 11 05/02/85 00:00 600 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 04 1. 04 11 05/03/85 02:00 601 21 1. 05 1. 05 11 05/03/85 04:00 602 21 1. 05 1. 05 11 05/03/85 06:00 603 21 1. 05 1. 05 11 05/03/85 08:00 604 21 1. 05 1. 05 11 05/03/85 10:00 605 21 1. 05 1. 05 11 05/03/85 12:00 606 21 1. 05 1. 05 11 05/03/85 14:00 607 21 1. 05 1. 05 11 os/03/85 16:oo· 608 21 1. 05 1. 05 11 05/03/85 18:00 609 21 1. 05 1. 05 11 05103/85 20:00 610 21 1. 05 1. 05 11 05/03/85 22:00 611 21 1. OS 1. 05 11 05/03/85 00:00 612 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 18 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ======·= ======= ==== ========== ====== ===== ======= 05/04/8S 02:00 613 21 1. 05 1. OS 11 05/04/8S 04:00 614 21 1. 05 1 OS 11 OS/04/8S 06:00 615 20 1. 00 1. 00 9. 5 05/04/85 08:00 616 21 1. 05 1. 05 11 05/04/8S 10:00 617 21 1. 05 1. OS 11 05/04/8S 12:00 618 20 1. 00 1. 00 9. 5 05/04/8S 14:00 619 21 1. 05 1. OS 11 OS/04/8S 16:00 620 21 1. 05 1. 05 11 OS/04/85 18:00 621 21 1. OS 1. 05 11 05/04/85 20:00 622 21 1. OS 1. 05 11 05/04/85 22:00 623 21 1. 05 1. OS 11 05/04/85 00:00 624 21 1. OS 1 OS 11 DAILY AVERAGE VALUES 1. 04 1. 04 11 05/05/8S 02:00 625 21 1. 05 1. OS 11 05/05/85 04:00 626 21 1. 05 1. 05 11 05/05/85 06:00 627 21 1. 05 1. 05 11 05/05/85 08:00 628 21 1. OS 1. OS 11 05/0S/85 10:00 629 21 1. 05 1. 05 11 05/0S/8S 12:00 630 21 1. 05 1. 05 11 05/05/85 14:00 631 22 1. 10 1. 10 12 05/0S/85 16:00 632 22 1. 10 1. 10 12 05/0S/85 18:00 633 22 1. 10 1. 10 12 05/05/85 20:00 634 22 1. 10 1. 10 12 05/0S/85 22:00 635 22 1. 10 1. 10 12 05/05/85 00:00 636 22 1 10 1. 10 12 DAILY AVERAGE VALUES 1. 08 1. 08 12 05/06/85 02:00 637 22 1. 10 1. 10 12 -05/06/85 04:00 638 22 1. 10 1. 10 12 OS/06/85 06:00 639 23 1. 1S 1. 15 13 05/06/85 08:00 640 25 1. 25 1. 25 16 05/06/85 10:00 641 29 1. 4S 1. 45 23 05/06/85 12:00 642 29 1. 45 1. 45 23 05/06/85 14:00 643 28 1. 40 1. 40 21 05106/85 16:00 644 27 1. 35 1. 35 19 05/06/85 18:00 645 27 1. 35 1. 35 19 05106/85 20: 00 646 26 1. 30 1. 30 18 05/06/85 22:00 647 25 1. 25 1. 25 16 05/06/85 00:00 648 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 28 1. 28 17 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 19 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =••=====• :u:z:a== ==·= ========= ======= ===== ====== 05/07/85 02:00 649 24 1. 20 1. 20 15 05/07/85 04:00 650 24 1. 20 1. 20 15 05/07/85 06:00 651 24 1. 20 1. 20 15 05/07/85 08:00 652 24 1. 20 1. 20 15 05/07/85 10:00 653 23 1. 15 1. 15 13 05/07/85 12:00 654 24 1. 20 1. 20 15 05/07/85 14:00 655 24 1. 20 1. 20 15 05/07/85 16:00 656 24 1. 20 1. 20 15 05/07/85 18:00 657 24 1. 20 1. 20 15 05/07/85 20:00 658 26 1. 30 1. 30 18 05/07/85 22:00 659 25 1. 25 1. 25 16 05/07/85 00:00 660 25 1. 25 1. 25 16 DAILY AVERAGE VALUES 1. 21 1. 21 15 05/08/85 02:00 661 25 1. 25 1. 25 16 05/08/85 04:00 662 24 1. 20 1. 20 15 05/08/85 06:00 663 24 1. 20 1. 20 15 05/08/85 08:00 664 24 1. 20 1. 20 15 05/08/85 10:00 665 23 1. 15 1. 15 13 05/08/85 12:00 666 23 1. 15 1. 15 13 05/08/85 14:00 667 23 1. 15 1. 15 13 05/08/85 16:00 668 23 1. 15 1. 15 13 05/08/85 18:00 669 23 1. 15 1 15 13 05/08/85 20:00 670 23 1. 15 1. 15 13 05/08/85 22:00 671 23 1. 15 1. 15 13 05/08/85 00:00 672 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 17 1. 17 14 05/09/85 02:00 673 23 1. 15 1. 15 13 05/09/85 04:00 674 23 1. 15 1. 15 13 05/09/85 06:00 675 22 1. 10 1. 10 12 05/09/85 08:00 676 22 1. 10 1. 10 12 05/09/85 10:00 677 22 1. 10 1. 10 12 05/09/85 12:00 678 22 1. 10 1. 10 12 05/09/85 14:00 679 22 1. 10 1. 10 12 05/09/85 16:00 680 22 1. 10 1. 10 12 05/09/85 18:00 681 22 1. 10 1 10 12 05/09/85 20:00 682 22 1. 10 1. 10 12 05/09/85 22:00 683 22 1. 10 1. 10 12 05/09/85 00:00 684 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1.11 1. 11 12 PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 20 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ==·==·== ==-=== ==== ========= =·==== ======= ======= 05/10/85 02:00 685 22 1. 10 1. 10 12 05/10/85 04:00 686 22 1. 10 1. 10 12 05/10/85 06:00 687 22 1. 10 1. 10 12 05/10/85 08:00 688 22 1. 10 1. 10 12 '1 "!:! 05/10/85 10:00 689 22 1. 10 1. 10 12 05/10/85 12:00 690 22 1 10 1. 10 12 05/10/85 14:00 691 22 1. 10 1. 10 12 05/10/85 16:00 692 22 1. 10 1. 10 12 05/10/85 18:00 693 22 1. 10 1. 10 12 05/10/85 20:00 694 22 1. 10 1. 10 12 05/10/85 22:00 695 21 1. 05 1. 05 11 05/10/85 00:00 696 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 10 1. 10 12 05/11/85 02:00 697 22 1. 10 1. 10 12 05/11/85 04:00 698 22 1. 10 1. 10 12 05/11/85 06:00 699 21 1. 05 1. 05 11 05/11/85 08:00 700 22 1. 10 1. 10 12 05/11/85 10:00 701 22 1. 10 1. 10 12 05/11/85 12: 00 702 22 1. 10 1. 10 12 05/11/85 14:00 703 21 1. 05 1. 05 11 05/11/85 16:00 704 22 1. 10 1. 10 12 05/11/85 18:00 705 21 1. 05 1. 05 11 05/11/85 20:00 706 22 1. 10 1. 10 12 05/11/85 22:00 707 21 1. 05 1. 05 11 05/11/85 00:00 708 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 08 1. 08 12 05/12/85 02:00 709 21 1. 05 1. 05 11 05/12/85 04:00 710 22 1. 10 1. 10 12 05/12/85 06:00 711 21 1. 05 1. 05 11 05/12/85 08:00 712 21 1. 05 1. 05 11 05/12/85 10:00 713 22 1. 10 1. 10 12 05/12/85 12:00 714 22 1. 10 1. 10 12 05/12/85 14:00 715 21 1. 05 1. 05 11 05/12/85 16:00 716 21 1. 05 1. 05 11 05/12/85 18:00 717 21 1. 05 1. 05 11 05/12/85 20:00 718 21 1. 05 1. 05 11 05/12/85 22:00 719 21 1. 05 1. 05 11 05/12/85 00:00 720 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 06 1. 06 11 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 21 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =======· -====· ===== =====·=== ==·-== ===== ====== 05/13/85 02:00 721 21 1. 05 1. 05 11 05/13/85 04:00 722 21 1. 05 1. 05 11 05/13/85 06:00 723 21 1. 05 1. 05 11 05/13/85 08:00 724 21 1. 05 1. 05 11 05/13/85 10:00 725 21 1. 05 1. 05 11 '! 05/13/85 12:00 726 21 1. 05 1. 05 11 '·" 05/13/85 14:00 727 21 1. 05 1. 05 11 f, 05/13/85 16:00 728 21 1. 05 1. 05 11 ~ 05/13/85 18:00 729 21 1. 05 1 05 11 05/13/85 20:00 730 21 1. 05 1. 05 11 05/13/85 22:00 731 21 1. 05 1. 05 11 05/13/85 00:00 732 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 05 1. 05 11 05/14/85 02:00 733 21 1. 05 1. 05 11 05/14/85 04:00 734 22 1. 10 1. 10 12 05/14/85 06:00 735 22 1. 10 1. 10 12 05/14/85 08:00 736 23 1. 15 1. 15 13 05/14/85 10:00 737 23 1. 15 1. 15 13 05/14/85 12:00 738 23 1. 15 1. 15 13 05/14/85 14:00 739 22 1. 10 1. 10 12 05/14/85 16:00 740 21 1. 05 1. 05 11 05/14/85 18:00 741 22 1. 10 1. 10 12 05/14/85 20:00 742 21 1. 05 1. 05 11 05/14/85 22:00 743 21 1. 05 1. 05 11 05/14/85 00:00 744 21 1. 05 1. 05 11 DAILY AVERAGE VALUES 1. 09 1. 09 12 05/15/85 02:00 745 21 1. 05 1. 05 11 05/15/85 04:00 746 21 1. 05 1. 05 11 05/15/85 06:00 747 21 1. 05 1. 05 11 05/15/85 08:00 748 22 1. 10 1. 10 12 05/15/85 10:00 749 22 1. 10 1. 10 12 05/15/85 12:00 750 21 1. 05 1. 05 11 05/15/85 14:00 751 21 1. 05 1. 05 11 05/15/85 16:00 752 22 1. 10 1. 10 12 05/15/85 18:00 753 22 1. 10 1. 10 12 05/15/85 20:00 754 23 1. 15 1. 15 13 05/15/85 22:00 755 23 1. 15 1. 15 13 05/15/85 00:00 756 22 1. 10 1. 10 12 DAILY AVERAGE VALUES 1. 09 1. 09 12 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 22 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ·======= ===== ==== =··====== ==·=== ===== ====== 05/16/85 02:00 757 22 1. 10 1. 10 12 05/16/85 04:00 758 22 1. 10 1. 10 12 05/16/85 06:00 759 22 1. 10 1. 10 12 r :1 rt 05/16/85 08:00 760 22 1. 10 1. 10 12 '• .. ,, 05/16/85 10:00 761 22 1. 10 1. 10 12 05/16/85 12:00 762 22 1. 10 1 10 12 05/16/85 14:00 763 22 1. 10 1. 10 12 05/16/85 16:00 764 22 1. 10 1. 10 12 05/16/85 18:00 765 22 1. 10 1. 10 12 05/16/85 20:00 766 22 1. 10 1. 10 12 05/16/85 22:00 767 22 1. 10 1. 10 12 05/16/85 00:00 768 23 1. 15 1. 15 13 DAILY AVERAGE VALUES 1. 10 1. 10 12 05/17/85 02:00 769 28 1. 40 1. 40 21 05/17/85 04:00 770 32 1. 60 1. 60 29 05/17/85 06:00 771 34 1. 70 1. 70 34 05/17/85 08:00 772 34 1. 70 1. 70 34 05/17/85 10:00 773 35 1. 75 1. 75 36 05/17/85 12:00 774 37 1. 85 1. 85 41 05/17/85 14:00 775 39 1. 95 1. 95 47 05/17/85 16:00 776 40 2. 00 2.00 50 05/17/85 18:00 777 40 2. 00 2. 00 50 05/17/85 20:00 778 39 1. 95 1. 95 47 05/17/85 22:00 779 37 1. 85 1. 85 41 05/17/85 00:00 780 37 1. 85 1. 85 41 DAILY AVERAGE VALUES 1. 80 1. 80 39 05/18/85 02:00 781 33 1. 65 1. 65 31 05/18/85 04:00 782 31 1. 55 1. 55 27 05/18/85 06:00 783 31 1. 55 1. 55 27 05/18/85 08:00 784 30 1. 50 1. 50 25 05/18/85 10:00 785 30 1. 50 1. 50 25 05/18/85 12:00 786 29 1. 45 1. 45 23 05/18/85 14:00 787 30 1. 50 1. 50 25 05/18185 16: oo· 788 31 1. 55 1. 55 27 05/18/85 18:00 789 31 1. 55 1. 55 27 05/18/85 20:00 790 31 1. 55 1. 55 27 05/18/85 22:00 791 30 1. 50 1. 50 25 05/18/85 00:00 792 29 1. 45 1.45 23 DAILY AVERAGE VALUES 1. 53 1. 53 26 PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 23 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ========= ====== ==== ========== ====== ===== ====== 00/19/85 02:00 793 29 1. 45 1 45 23 05/19/85 04:00 794 28 1. 40 1. 40 21 05/19/85 06:00 795 28 1. 40 1. 40 21 .~:'~~e. 05/19/85 08:00 796 28 1. 40 1. 40 21 ' ' ~ }} \! 05/19/85 10:00 797 27 1. 35 1. 35 19 :> 05/19/85 12:00 798 27 1. 35 1. 35 19 05/19/85 14:00 799 27 1. 35 1. 35 19 05/19/85 16:00 800 28 1. 40 1. 40 21 05/19/85 18:00 801 29 1. 45 1. 45 23 05/19/85 20:00 802 30 1. so 1. 50 25 05/19/85 22:00 803 29 1. 45 1. 45 23 05/19/85 00:00 804 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 41 1. 41 22 05/20/85 02:00 805 28 1. 40 1. 40 21 05/20/85 04:00 806 28 1. 40 1. 40 21 05/20/85 06:00 807 28 1. 40 1. 40 21 05/20/85 08:00 808 27 1. 35 1. 35 19 05/20/85 10:00 809 27 1. 35 1. 35 19 05/20/85 12:00 810 27 1. 35 1. 35 19 05/20/85 14:00 811 27 1. 35 1. 35 19 05/20/85 16:00 812 27 1. 35 1. 35 19 05/20/85 18:00 813 27 1. 35 1. 35 19 05/20/85 20:00 814 27 1. 35 1. 35 19 05/20/85 22:00 815 27 1. 35 1. 35 19 05/20/85 00:00 816 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 36 1. 36 20 05/21/85 02:00 817 27 1. 35 1. 35 19 05/21/85 04:00 818 27 1. 35 1. 35 19 05/21/85 06:00 819 27 1. 35 1. 35 19 05/21/85 08:00 820 27 1. 35 1. 35 19 05/21/85 10:00 821 27 1. 35 1. 35 19 05/21/85 12: 00 822 27 1. 35 1. 35 19 05/21/85 14:00 823 27 1. 35 1. 35 19 05/21185 16: 00 824 27 1. 35 1. 35 19 05/21/85 18:00 825 27 1. 35 1. 35 19 05/21/85 20:00 826 27 1. 35 1. 35 19 05/21/85 22:00 827 27 1. 35 1. 35 19 05/21/85 00:00 828 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 35 1. 35 19 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 24 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ==·==·== ===== ==== ======·=== ==·=== ===·-====== 05/22/85 02:00 829 28 1. 40 1. 40 21 05/22/85 04:00 830 28 1. 40 1. 40 21 05/22/85 06:00 831 27 1. 35 1. 35 19 05/22/85 08:00 832 27 1. 35 1. 35 19 < ,,, h 05/22/85 10:00 833 27 1. 35 1. 35 19 05/22/85 12:00 834 28 1. 40 1. 40 21 05/22/85 14:00 835 28 1. 40 1. 40 21 05/22/85 16:00 836 28 1. 40 1. 40 21 05/22/8:5 18:00 837 29 1. 45 1 45 23 05/22/85 20:00 838 29 1. 45 1. 45 23 05/22/8:5 22:00 839 29 1. 45 1. 45 23 05/22/85 00:00 840 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 40 1. 40 21 05/23/85 02:00 841 29 1. 45 1. 45 23 05/23/8:5 04:00 842 29 1. 45 1. 45 23 05/23/85 06:00 843 29 1. 45 1. 45 23 05/23/85 08:00 844 28 1. 40 1. 40 21 05/23/85 10:00 845 28 1. 40 1. 40 21 05/23/85 12:00 846 28 1. 40 1. 40 21 05/23/85 14:00 847 28 1. 40 1. 40 21 05/23/85 16:00 848 28 1. 40 1. 40 21 05/23/85 18:00 849 29 1. 45 1. 45 23 05/23/85 20:00 850 29 1. 45 1. 45 23 05/23/85 22:00 851 29 1. 45 1. 45 23 05/23/85 00:00 852 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 43 1. 43 22 05/24/85 02:00 853 28 1. 40 1. 40 21 05/24/85 04:00 8:54 28 1. 40 1. 40 21 05/24/8:5 06:00 8:55 28 1. 40 1. 40 21 05/24/85 08:00 856 27 1. 35 1. 35 19 0:5/24/85 10:00 857 27 1. 35 1 35 19 05/24/8:5 12:00 858 27 1. 3:5 1. 35 19 05/24/85 14:00 859 27 1. 35 1. 35 19 05/24/85 16:00 860 27 1. 35 1. 35 19 05/24/85 18:00 861 28 1. 40 1. 40 21 0:5/24/85 20:00 862 29 1. 45 1. 45 23 05/24/85 22:00 863 29 1. 45 1. 45 23 05/24/85 00:00 864 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 39 1. 39 21 PROPOSED KING COVE HYDROELETRIC PRO~ECT 06/24/85 PAGE 25 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ======·= ===== --== ========= ·===== ===== ====== 05/25/85 02:00 865 29 1. 45 1. 45 23 05/25/85 04:00 866 28 1. 40 1. 40 21 05/25/85 06:00 867 28 1. 40 1. 40 21 05/25/85 08:00 868 28 1. 40 1. 40 21 ., "' 05/25/85 10:00 869 28 1. 40 1. 40 21 05/25/85 12:00 870 27 1. 35 1. 35 19 05/25/85 14:00 871 28 1. 40 1. 40 21 05/25/85 16:00 872 29 1. 45 1. 45 23 05/25/85 18:00 873 31 1. 55 1. 55 27 05/25/85 20:00 874 31 1. 55 1. 55 27 05/25/85 22:00 875 31 1. 55 1. 55 27 05/25/85 00:00 876 30 1. 50 1. 50 25 DAILY AVERAGE VALUES 1. 45 1. 45 23 05/26/85 02:00 877 30 1. 50 1. 50 25 05/26/85 04:00 878 29 1. 45 1. 45 23 05/26/85 06:00 879 29 1. 45 1. 45 23 05/26/85 08:00 880 28 1. 40 1. 40 21 05/26/85 10:00 881 28 1. 40 1. 40 21 05/26/85 12:00 882 28 1. 40 1. 40 21 05/26/85 14:00 883 28 1. 40 1. 40 21 05/26/85 16:00 884 28 1. 40 1. 40 21 05/26/85 18:00 885 29 1. 45 1. 45 23 05/26/85 20:00 886 30 1. 50 1. 50 25 05/26/85 22:00 887 31 1. 55 1. 55 27 05/26/85 00:00 888 31 1. 55 1. 55 27 DAILY AVERAGE VALUES 1. 45 1. 45 23 05/27/85 02:00 889 31 1. 55 1. 55 27 05/27/85 04:00 890 30 1. 50 1. 50 25 05/27/85 06:00 891 30 1. 50 1. 50 25 05/27/85 08:00 892 30 1. 50 1. 50 25 05/27/85 10:00 893 30 1. 50 1. 50 25 05/27/85 12:00 894 30 1. 50 1. 50 25 05/27/85 14:00 895 30 1. 50 1. 50 25 05/27/85 16:00 896 33 1. 65 1. 65 31 05/27/85 18:00 897 35 1. 75 1. 75 36 05/27/85 20:00 898 34 1. 70 1. 70 34 05/27/85 22:00 899 33 1. 65 1. 65 31 05/27/85 00:00 900 32 1. 60 1. 60 29 DAILY AVERAGE VALUES 1. 58 1. 58 28 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 26 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =====•::a= =·==== ==== ==·====== ======= ·===== ====== 05/28/85 02:00 901 31 1. 55 1. 55 27 05/28/85 04:00 902 31 1. 55 1. 55 27 05/28/85 06:00 903 30 1. 50 1. 50 25 05/28/85 08:00 904 31 1. 55 1. 55 27 05/28/85 10:00 905 30 1. 50 1. 50 25 05/28/85 12:00 906 30 1. 50 1. 50 25 05/28/85 14:00 907 31 1. 55 1. 55 27 05/28/85 16:00 908 31 1. 55 1. 55 27 05/28/85 18:00 909 32 1. 60 1. 60 29 05/28/85 20:00 910 31 1. 55 1. 55 27 05/28/85 22:00 911 31 1. 55 1. 55 27 05/28/85 00:00 912 31 1. 55 1. 55 27 DAILY AVERAGE VALUES 1. 54 1. 54 27 05/29/85 02:00 913 31 1. 55 1. 55 27 05/29/85 04:00 914 31 1. 55 1. 55 27 05/29/85 06:00 915 30 1 50 1. 50 25 05/29/85 08:00 916 30 1. 50 1. 50 25 05/29/85 10:00 917 30 1. 50 1. 50 25 05/29/85 12:00 918 30 1. 50 1. 50 25 05/29/85 14:00 919 30 1. 50 1. 50 25 05/29/85 16:00 920 30 1. 50 1. 50 25 05/29/85 18:00 921 32 1. 60 1. 60 29 05/29/85 20:00 922 34 1. 70 1. 70 34 05/29/85 22:00 923 34 1. 70 1. 70 34 05/29/85 00:00 924 34 1. 70 1. 70 34 DAILY AVERAGE VALUES 1. 57 1. 57 28 05/30/85 02:00 925 33 1. 65 1. 65 31 .. 05/30/85 04:00 926 32 1. 60 1. 60 29 05/30/85 06:00 927 32 1. 60 1. 60 29 05/30/85 08:00 928 31 1. 55 1. 55 27 05/30/85 10:00 929 31 1. 55 1. 55 27 05/30/85 12:00 930 31 1. 55 1. 55 27 05/30/85 14:00 931 31 1. 55 1. 55 27 05/30/85 16:00 932 31 1. 55 1. 55 27 05/30/85 18:00 933 32 1. 60 1. 60 29 05/30/85 20:00 934 32 1. 60 1. 60 29 05/30/85 22:00 935 32 1. 60 1. 60 29 05/30/85 00:00 936 32 1. 60 1. 60 29 DAILY AVERAGE VALUES 1. 58 1. 58 28 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 27 DELTA CREEK NEAR KING COVE. ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ====·==· ==:==== ==== =========== ====== ====== ======= 05/31/85 02:00 937 32 1. 60 1. 60 29 05/31/85 04:00 938 31 1. 55 1. 55 27 05/31/85 06:00 939 31 1. 55 1. 55 27 r·'">J 05/31/85 08:00 940 30 1. so 1. 50 25 05/31/85 10:00 941 30 1. 50 1. so 25 05/31/85 12:00 942 30 1. 50 1. 50 25 05/31/85 14:00 943 29 1. 45 1. 45 23 05/31/85 16:00 944 30 1. so 1. so 2S 05/31/85 18:00 945 30 1. 50 1. so 25 05/31/85 20:00 946 30 1. 50 1. 50 25 05/31185 22:00 947 29 1. 45 1. 45 23 05/31/85 00:00 948 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 50 1. 50 25 06/01/85 02:00 949 28 1. 40 1 40 21 06/01/85 04:00 950 28 1. 40 1. 40 21 06/01/85 06:00 951 29 1. 45 1. 4S 23 06/01/85 08:00 952 28 1. 40 1. 40 21 06/01/85 10:00 953 28 1. 40 1. 40 21 06/01/85 12:00 954 28 1. 40 1. 40 21 06/01/8S 14:00 9S5 28 1. 40 1. 40 21 06/01/8S 16:00 956 27 1. 35 1. 35 19 06/01/85 18:00 957 28 1. 40 1. 40 21 06/01/8S 20:00 958 28 1. 40 1. 40 21 06/0118S 22:00 959 27 1. 35 1. 35 19 06/01/85 00:00 960 27 1. 3S 1 35 19 DAILY AVERAGE VALUES 1. 39 1. 39 21 06/02/85 02:00 961 27 1. 35 1. 3S 19 06/02/85 04:00 962 27 1. 35 1. 35 19 06/02/85 06:00 963 27 1. 35 1. 35 19 06/02/85 08:00 964 27 1. 35 1. 3S 19 06/02/85 10:00 965 27 1. 35 1. 35 19 06/02/85 12:00 966 27 1. 35 1. 35 19 06/02/85 14:00 967 26 1. 30 1. 30 18 06/02/85 16:00 968 27 1. 35 1. 35 19 06/02/85 18:00 969 27 1. 35 1. 35 19 06/02/85 20:00 970 27 1. 35 1. 35 19 06/02/85 22:00 971 27 1. 35 1. 35 19 06/02/85 00:00 972 27 1. 35 1. 35 19 DAILY AVERAGE VALUES 1. 35 1. 35 19 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 28 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =====·== ====· ==== ====·==== ====== ===== ====== 06/03/85 02:00 973 27 1. 35 1. 35 19 06/03/85 04:00 974 27 1. 35 1. 35 19 ~ ~ A ~i 06/03/85 06:00 975 27 1. 35 1. 35 19 06/03/85 08:00 976 27 1. 35 1. 35 19 ;, .~ 06/03/85 10:00 977 28 1. 40 1. 40 21 06/03/85 12:00 978 28 1. 40 1. 40 21 06/03/85 14:00 979 29 1. 45 1. 45 23 06/03/85 16:00 980 29 1. 45 1. 45 23 06/03/85 18:00 981 29 1. 45 1. 45 23 06/03/85 20:00 982 29 1. 45 1. 45 23 06/03/85 22:00 983 29 1. 45 1. 45 23 06/03/85 00:00 984 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 41 1. 41 21 06/04/85 02:00 985 28 1. 40 1. 40 21 06/04/85 04:00 986 28 1. 40 1. 40 21 06/04/85 06:00 987 28 1. 40 1. 40 21 06/04/85 08:00 988 28 1. 40 1. 40 21 06/04/85 10:00 989 28 1. 40 1. 40 21 06/04/85 12:00 990 28 1. 40 1. 40 21 06/04/85 14:00 991 29 1. 45 1. 45 23 06/04/85 16:00 992 29 1. 45 1. 45 23 06/04/85 18:00 993 30 1. 50 1. 50 25 06/04/85 20:00 994 30 1. 50 1. 50 25 06/04/85 22:00 995 30 1. 50 1. 50 25 06/04/85 00:00 996 29 1. 45 1. 45 23 DAILY AVERAGE VALUES 1. 44 1. 44 23 06/05/85 02:00 997 29 1. 45 1. 45 23 • 06/05/85 04:00 998 29 1. 45 1 45 23 06/05/85 06:00 999 28 1. 40 1. 40 21 06/05/85 08:00 000 28 1. 40 1. 40 21 06/05/85 10:00 001 28 1. 40 1. 40 21 06/05/85 12:00 002 28 1. 40 1. 40 21 06/05/85 14:00 003 28 1. 40 1. 40 21 06/05/85 16:00 004 28 1. 40 1. 40 21 06/05/85 18:00 005 29 1. 45 1. 45 23 06/05/85 20:00 006 29 1. 45 1. 45 23 06/05/85 22:00 007 29 1. 45 1. 45 23 06/05/85 00:00 008 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 42 1. 42 22 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 29 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS =··===== ==·=· ===== ========= ====== ===== ======= 06/06/85 02:00 009 28 1. 40 1. 40 21 06/06/85 04:00 010 28 1. 40 1. 40 21 06/06/85 06:00 011 28 1. 40 1. 40 21 06/06/85 08:00 012 27 1. 35 1. 35 19 06/06/85 10:00 013 27 1. 35 1. 35 19 06/06/85 12:00 014 27 1. 35 1. 35 19 06/06/85 14:00 015 27 1. 35 1. 35 19 06/06/85 16:00 016 28 1. 40 1. 40 21 06/06/85 18:00 017 28 1. 40 1. 40 21 06/06/85 20:00 018 28 1. 40 1. 40 21 06/06/85 22:00 019 28 1. 40 1. 40 21 06/06/85 00:00 020 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 38 1. 38 20 06/07/85 02:00 021 28 1. 40 1. 40 21 06/07/85 04:00 022 28 1. 40 1. 40 21 06/07/85 06:00 023 27 1. 35 1. 35 19 06/07/85 08:00 024 27 1. 35 1. 35 19 06/07/85 10:00 025 27 1. 35 1. 35 19 06/07/85 12:00 026 27 1. 35 1. 35 19 06/07/85 14:00 027 27 1. 35 1. 35 19 06/07/85 16:00 028 27 1. 35 1. 35 19 06/07/85 18:00 029 28 1. 40 1. 40 21 06/07/85 20:00 030 29 1. 45 1. 45 23 06/07/85 22:00 031 28 1. 40 1. 40 21 06/07/85 00:00 032 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 38 1. 38 20 06/08/85 02:00 033 28 1. 40 1. 40 21 06/08/85 04:00 034 28 1. 40 1. 40 21 06/08/85 06:00 035 28 1. 40 1. 40 21 06/08/85 08:00 036 27 1. 35 1. 35 19 06/08/85 10:00 037 27 1. 35 1. 35 19 06/08/85 12:00 038 27 1. 35 1. 35 19 06/08/85 14:00 039 28 1. 40 1. 40 21 06/08/85 16:00 040 28 1. 40 1. 40 21 06/08/85 18:00 041 28 1. 40 1. 40 21 06/08/85 20:00 042 28 1. 40 1. 40 21 06/08/85 22:00 043 28 1. 40 1. 40 21 06/08/85 00:00 044 28 1. 40 1. 40 21 DAILY AVERAGE VALUES 1. 39 1. 39 21 PROPOSED KING COVE HYDROELETRIC PROJECT 06/24/85 PAGE 30 DELTA CREEK NEAR KING COVE, ALASKA START TIME 03/14/85 02:00 DEPTH STAGE DISCHG DATE TIME BYTE RAW DATA FEET FEET CFS ======== ====== ===== ========== ====== ===== ====== 06/09/85 02:00 045 27 1. 35 1. 35 19 06/09/85 04:00 046 27 1. 35 1. 35 19 06/09/85 06:00 047 27 1. 35 1. 35 19 06/09/85 08:00 048 28 1. 40 1. 40 21 06/09/85 10:00 049 29 1. 45 1. 45 23 06/09/85 12:00 050 30 1. 50 1. 50 25 06/09/85 14:00 051 30 1. 50 1. 50 25 06/09/85 16:00 052 31 1. 55 1. 55 27 06/09/85 18:00 053 31 1. 55 1. 55 27 06/09/85 20:00 054 31 1. 55 1. 55 27 06/09/85 22:00 055 31 1. 55 1. 55 27 06/09/85 00:00 056 32 1. 60 1. 60 29 DAILY AVERAGE VALUES 1. 48 1. 48 24 06/10/85 02:00 057 32 1. 60 1. 60 29 06/10/85 04:00 058 31 1. 55 1. 55 27 06/10/85 06:00 059 31 1. 55 1. 55 27 06/10/85 08:00 060 30 1. 50 1. 50 25 06/10/85 10:00 061 30 1. 50 1. 50 25 06/10/85 12:00 062 29 1. 45 1. 45 23 06/10/85 14:00 063 30 1. 50 1. 50 25 06/10/85 16:00 064 30 1. 50 1. 50 25 06/10/85 18:00 065 31 1. 55 1. 55 27 06/10/85 20:00 066 32 1. 60 1. 60 29 06/10/85 22:00 067 31 1. 55 1. 55 27 06/10/85 00:00 068 31 1. 55 1. 55 27 DAILY AVERAGE VALUES 1. 53 1. 53 26 06/11185 02: 00 069 31 1. 55 1. 55 27 06/11/85 04:00 070 30 1. 50 1. 50 25 06/11/85 06: 00 071 30 1. 50 1. 50 25 06/11/85 08:00 072 29 1. 45 1. 45 23 06/11/85 10:00 073 29 1. 45 1. 45 23 06/11/85 12: 00 074 30 1. 50 1. 50 25 06/11/85 14:00 075 31 1. 55 1. 55 27 06/11/85 16: 00 076 34 1. 70 1. 70 34 06/11/85 18:00 077 36 1. 80 1. 80 39 06/11/85 20: 00 078 35 1. 75 1. 75 36 06/11/85 22:00 079 35 1. 75 1. 75 36 06/11/85 00:00 080 34 1. 70 1. 70 34 DAILY AVERAGE VALUES 1. 60 1. 60 30 PROPOSED KING COVE HVDROELETRIC PROJECT DELTA CREEK NEAR KING COVE• ALASKA DATE TIME BVTE RAW DATA C&!llht::•=•= w::u==•z: ===::: ·======-·= 06/12/8, 02:00 081 34 06/12/8, 04:00 082 33 06/12/8, 06:00 083 32 06/12/8, 08:00 084 32 06/12/8, 10:00 085 32 06/12/8, 12:00 ORb 31 DAILY MvERAGE VALUES DEPTH FEET ====== 1. 70 1. 65 1. 60 1. 60 1. 60 1. 5' 06/24/85 PAGE 31 START TIME 03/14/85 02:00 STAGE FEET ==•=s: 1. 70 1. 6' 1. 60 1. 60 1. 60 1. 55 DISCHG CFS =====::a-= 34 31 29 29 29 27 N ~ .. 1\ I ....... l:: ~ 'ft' ! 'j' ~ t:,: ' ,~ ·. ' •• \11, p