Bradley River Water Quality Report 1986
"RECORD COPY" RETURN TO BRADLEY O&M FILES ... AlasKa Power Autnor1ry BRADLEY RIVER WATER QUALITY REPORT 1986 BRADLEY LAKE HYDROELECTRIC PROJECT FEDERAL ENERGY REGULATORY COMMISSION PROJECT NO. P-8221-000 Prepared By STONE & WEBSTER ENGINEERING CORPORATION ANCHORAGE , ALASKA January 1987 1 I 0~3 BRADLEY LAKE HYDROELECTRIC PROJECT 1986 BRADLEY RIVER WATER QUALITY REPORT TABLE OF CONTENTS 1.0 Introduction 1986 WATER QUALITY REPORT BRADLEY RIVER Table of Contents 2.0 Equipment Servicing 3.0 Data Description 4.0 Miscellaneous Data Attachments I Riffle Reach Attachments II Tree Bar Reach Attachments III -North Fork Bradley River 2 3 4 REPORT ,- 1.0 INTRODUCTION The purpose of the 1986 Water Quality Report is to comply with Article 33 of the Federal Energy Regulatory Commission License and augment the current water baseline data for the Bradley Lake Hydroelectric Project. The 1986 water quality program consisted of a continuation of monitoring water temperature at three locations on the lower Bradley River. Continuous surface and intragravel water temperatures were collected via Datapod Model 212 recorders. The three monitoring sites on the lower Bradley River are: 1. North Fork Bradley River, about 100 yards upstream from the confluence of the North Fork with the lower Bradley River. 2. Lower Bradley River near Riffle Reach. 3. Lower Bradley River near Tree Bar Reach. Each site is shown on Figure 1. The recorders at Riffle and Tree Bar Reaches record average temperatures over 2 hour intervals. The surface water temperature probes are fixed within the top 3 inches of the streambed and the 2-488-KB intragravel probe is located in about 18 inches of streambed gravel in a perforated probe. The recorder at the North Fork of Bradley River has one temperature probe and records average temperature values every 6 hours and also has a pressure transducer for stage recording. 2.0 EQUIPHENT SERVICING Each da tapod recorder is serviced on a monthly basis and after higher than normal river flow events. During each visit in 1986, the batteries were checked and a short dump was performed. The dump produced temperature readings from each of the two probes, the amount of space used on the chip, the time left until the next burn on the data chip, the recording interval and any errors. Chips are replaced approximately every other month. The datapod probes at Tree Bar Reach were torn out of the gravel on October 1, 1986. Later in October a major flood washed out the entire tree the probes were attached to. The datapod at Tree Bar Reach has not been replaced yet as another suitable site has not been found. The Alaska Power Authority Environmental Field Officer (EFO) resides on the project site, and performs any required equipment servicing. In the event that a major repair is required, datapod recorders are stored at the project site to enable on-the-spot replacement. 2-488-KB 2 3.0 DATA DESCRIPTION The data is presented in three attachments: Attachment I Riffle Reach Attachment II Tree Bar Reach Attachment III -North Fork Bradley River Riffle Reach data covers the period from December 1985 through December 1986. Channel 1 is the surface water temperature and Channel 2 is the intragravel water temperature. The daily average surface water temperature ranged from 0 -0.3 c to 0 12.9 c. Intragravel water temperatures in Riffle Reach ranged from -0. 1°C to 8.3°C during this period. Intragravel water temperatures remained fairly constant during Mid-February to mid-March. Tree Bar Reach data covers the period from February 1986 through September 1986. Channel 1 is the intragravel water temperature and Channel 2 is the surf'ace water temperature. Surface water temperatures are very similar to those in Riffle Reach during the same months whereas the intragravel temperatures for Tree Bar Reach were higher than those at Riffle Reach. Eventually the Tree Bar temperatures became similar to Riffle Reach temperatures. The surface water temperatures ranged from -0 .1°C to 9. 6°C while the intragravel water temperatures ranged from o0 c to 14.8°C. Surface 2-488-KB 3 water temperatures stayed below 0°C varying slightly during February and mid-March. Surface water temperatures increased after mid-March and then dropped at the end of March and remained near 0°C through mid April. North Fork Bradley River data covers the per·iod from December 1985 through November 1986. 0 Surface temperatures ranged from 0.6 C to 0 10.3 C. The difference in temperature characteristics may result from the location of the temperature sensor. Both surface and intragravel water temperatures respond to air temperature fluctuations. Intragravel temperatures were slightly warmer than surface water temperatures. Errors due to problems with the datapod, temperature probe, or the chip resulted in a temperature reading of 20.5. 4.0 MISCELLANEOUS DATA During Site Preparation Contract Construction work, samples were collected at several locations on the Bradley River and one at Bradley Lake in order to check the turbidity. The turbidity sample dates, location and results are listed below: 11/12/86 11/13/86 11/18/86 2-488-KB Tree Bar Reach 506 Tree Bar Reach 492 Tree Bar Reach 776 4 Location NTU Reading 11/22/86 Tree Bar Reach 763 11/22/86 Bradley Lake 508 11/28/86 Tree Bar Reach 282 12/5/86 Bradley Lake 426 12/5/86 North Fork Bradley River 1.7 12/5/86 Tree Bar Reach 750 12/5/86 Bradley River above the confluence of of the North Fork 1 '11 0 12/10/86 Riffle Reach 480 On 11/28/86 at Tree Bar Reach the turbidity was lower due to a temporary diversion. The turbidity sample on 12/10/86 at Riffle Reach was taken when the river started to flood. 2-488-KB 5 KACHEMAK BAY 0 IN 2 MILES ~tv~ ~ c ~" ~~~ *tv~~ "0 "'tv c,= ~tv~ ~ Ctv ~"~ ~~'f(>tv ~ Figure 1. Bradley lake Study Area showing stream gage location ettv "'tv :*-rF <cO~ t. fORV. ~"tv ~,d:>"-- ~<:> ATTACHMENT I RIFFLE REACH / ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH BEGIN OBS :NEED DATA BOOK END OBS DATE TIME BYTE RAW DATA ... --·---------------========== ------------- 12/28/85 12: l?l!Zi 1 58 60 12/28/85 14: !lf!ZI 3 58 6121 12/28/85 16:00 5 58 61.!1 12/28/85 18: 0121 7 59 61 12/28/85 2121: ~10 9 61 63 12/28/85 22: 1211!1 11 57 60 DAILY AVERAGE 12/29/85 0121: 1210 13 61 63 12/29/85 1212: 00 15 61 63 12/29/85 1214 : !!I 121 17 6!21 62 12/29/85 1!16: ~1!21 19 62 64 12/29/85 1!18: I!H!I 21 6~ ._, 65 12/29/85 l!ZI: 00 23 61 63 12/29/85 12: !li!ZI 25 61 63 12/29/85 14: 0l(J 27 62 65 12/29/85 16: Y.IY.I' 29 6!ZI 61 12/29/85 18:00 31 6121 62 12/29/85 2121: IZIQI 33 6!21 62 12/29/85 22: 0!21 35 60 61 DAILY AVERAGE 12/3121/85 1211!1 : IZHZI 37 59 61 12/30/85 1!12: illiZI 39 6121 62 12/3!21/85 1!14: 1210 41 59 61 12/3!21/85 1!16 : 1211!1 43 60 62 12/30/85 Y.18: 0!21 45 62 64 12/31!1/85 liZ! : !21!21 47 59 61 12/31!1/85 12:00 49 62 64 12/31!1/85 14: 121121 51 62 64 12/3!!1/85 16: 1210 53 61 6..,.. ._, 12/3121/85 18: 1211!1 55 62 64 12/3!.!1/85 20: !!1121 57 62 65 12/3121/85 22: !21!21 59 61 6"':!" .... DAILY AVERAGE CHAN 1 DEG c. ------------ 0.8 1!1. 8 l!l. 8 0.9 1. 1 0.7 VALUES ~1. 8 1.1 1.1 1.0 1.2 1. 3 1.1 1. 1 1.2 1.0 1.0 1.0 1.0 VALUES 1.1 -121. 9 1. 121 0.9 1. 121 1.2 121. 9 1.2 1.2 1.1 1. 2 1.2 1.1 VALUES 1.1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG c. ------------ 1.0 1. Ill 1. !21 1.1 1. 3 1.0 1.1 1. 3 1. 3 1.2 1.4 1.5 1.3 1. 3 1.5 1. 1 1.2 1.2 1.1 1. 3 1.1 1.2 1.1 1.2 1.4 1.1 1.4 1.4 1. 3 1.4 1.5 1. 3 1. 3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-!212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- 12/31/85 !210:0!~1 12/31/85 1!12: 121!21 12/31/85 04: !21!21 12/31/85 1!16: 1210 12/31/85 08:0121 12 I 31 I 85 11!1: 1210 12/31/85 12:121!21 12/31/85 14: 121121 12 I 31 I 85 16: Y.10 12/31/85 18: 1211!1 12/31/85 20: !210 12/31/85 22:121!21 1211 / i211 I 86 0121: 0121 ~!11 I 1211 /86 !212: 00 1211 I 1211 I 86 1214: 121121 12!1/!211/86 06:121!21 1211 I 121 1 /86 1218: 121!21 01/1211 I 86 liZ!: 1210 01/1211 /86 12! illiZI 01 /~11/86 14:1210 !211 /1211 I 86 16: 1!1121 1211 I !!11 I 86 18: 0!21 1211 /1!11 /86 20: !21121 1!11 /~11 /86 22:00 1211 I 02 I 86 121121: !21121 01 I !212 I 86 1212: 121!21 !!11 /02/86 04: !21!21 1!11 I !212 I 86 1216: 12H!I 01/02/86 08:00 1!11 I !!12 I 86 1!!1: I!H!I 0111212/86 12:00 1211 I 1!12 I 86 14: 121!21 1211 / 1212/ 86 16: 0!21 1211 I !212/86 18: 1!11!1 1!11 I !!12 /86 2121: 121121 i211 /IZI2/86 22: 121!21 BYTE RAW DATA ========== 61 58 61 63 61 63 65 55 57 67 57 59 69 59 6121 71 55 57 73 57 59 75 58 60 77 56 57 79 55 57 81 56 58 83 55 56 DAILY AVERAGE VALUES 85 56 58 87 57 59 89 55 57 91 56 58 93 57 59 95 52 54 97 55 57 99 57 59 101 52 54 103 57 59 11!15 58 6fl1 11217 55 57 DAILY AVERAGE VALUES 1!219 55 56 111 55 57 113 55 56 115 52 54 117 55 56 119 49 51 121 48 51 123 49 51 125 48 50 127 48 51 129 48 51 131 48 5121 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 0.8 1.1 121. 5 121. 7 !21. 9 !21. 5 0.7 lil. 8 121. 6 0.5 0.6 Ill. 5 0.7 0.6 0.7 0.5 0.6 121. 7 0.2 0.5 0.7 {21. 2 0.7 0.8 0.5 V.I. 6 121. 5 0.5 0.5 0.2 0.5 -f21. 1 -0.2 -121. 1 -0.2 -!21. 2 -0.2 -121. 2 121. 1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 1.1 1. 3 121. 7 IZI. 9 1.0 121. 7 0.9 1.0 f21. 7 0.7 0.8 0.6 0.9 0.8 121. 9 121.7 0.8 121. 9 0.4 0.7 121. 9 121. 4 121. 9 1. 121 121. 7 Ill. 8 0.6 I!J. 7 121. 6 0.4 0.6 121. 1 Ill. 1 121. 1 0. 121 0. 1 Ill. 1 121. 0 1!1. 3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 1211 I 03/86 1!112!: 1.!1121 01/1213/86 02: ic!1l21 1!11/03/86 04: 1'21121 I:H /QI3/86 1216: tll0 !211/03/86 ~18: Ji.f0 f£11/1213/86 1121: !210 01/£13/86 12:00 1211/03/86 14: !Zlfll 1!11 /03/86 16: !210 01/1213/86 18:1211!1 1211/1!13/86 20:1210 1211/1213/86 22:0121 1211 / 04 I 86 IZHZJ: 121!21 Y-11/!:!14/86 1212: 01!1 01/ 1!14 I 86 1214: 0!21 01/04/86 06:1.!10 01/1214/86 !218: ~1fll 121:1./1214/86 h1: 1210 1211 /lll4/86 12: 00 01 I 04/86 1 4 : 1210 01/1!14/86 16:r2H!I 01/04/86 18:00 S211 /04/86 2121: 0121 1.!11 ifll4/86 22:00 01/1!15/86 1!10: !c!10 1211 I !2!5/86 02: IZI!ZI !211/1215/86 04:00 01/05/86 1216a10 ~11 /!215/86 08:00 01/05/86 10:01!1 01/!215/86 12: 1210 1!11/05/86 14: 1!.1&::1 01 /li.l5/86 16:.00 1211/!215/86 18:Y.1fll ~~11/ (~15/86 2121: 0121 ~11/1!15/86 22:0121 BYTE RAW DATA ========== 133 48 51 135 48 51 137 48 5121 139 48 5!21 141 49 51 143 48 5121 145 48 51 147 51 54 149 48 50 151 55 57 153 56 58 155 52 54 DAILY AVERAGE VALUES 157 56 58 159 57 59 161 55 56 163 56 58 165 57 59 167 54 56 169 57 58 171 60 61 173 55 56 175 60 62 177 61 63 179 59 61 DAILY AVERAGE VALUES 181 58 6!21 183 59 61 185 57 59 187 58 60 189 60 61 191 57 59 193 59 61 195 60 62 197 58 60 199 59 61 201 60 62 21213 58 6121 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -!21. 2 -121. 2 -121.2 -0.2 -0.1 -u1. 2 -121.2 0.1 -0.2 0.5 0.6 0.2 -0.0 0.6 1!1. 7 0.5 f2j. 6 !21. 7 0.4 0.7 1. 0 0.5 1.0 1. 1_ 0.9 Ill. 7 0.8 0.9 0.7 0.8 1. 0 0.7 0 .. 9 1 • (21 r21. 8 0.9 1.0 121. 8 0.9 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 0.1 0.1 0. Ill Ill. lc!1 Ill. 1 !21. fll 0.1 0.4 0.0 0.7 t0.8 0.4 0.2 1'21. 8 0.9 Ql. 6 0.8 0.9 0.6 ll1. 8 1. 1 0.6 1. 2 1 .. 3 1.1 0.9 1.0 1.1 0.9 1.0 1. 1 fll. 9 1.1 1.2 1.0 1.1 1.2 1. IZI 1. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== !lll/06/86 1210:00 01/1216/86 02:121121 el1/06/86 04:00 01/06/86 !216:0{21 Ill l./ Qi6/ 86 08: !210 ~!11/!!16/86 10:00 01/06/86 12:00 IZH h::l6 I 86 14: 1!10 k!ll /06/86 16:00 101/06/86 18: 0121 01/1216/86 20:0121 1211/1216/86 22: 0~1 f!!l /1!17 /86 0121:0121 1211/9.17/86 02:00 01/1!17/86 1!14:1210 fill /Qi7 /86 06: 00 Ql1 N.l7 /86 08:00 Y.Sl/1!.!7 /86 10: !210 f2l1 /1!.17 /86 12: ll10 01/07/86 14:00 !2!1 /1!17 /86 16: fZIQI 0 1 I 1217 I 86 18: 00 01 I W.l7 I 86 21Cl: 1Zll21 1211/07/86 22:00 !211 I 1218 I 86 f210: 1210 01/08/86 02:00 f2H /1.!'18/86 04:00 IZI1/r.!l8/86 ~16:00 t111 /08/86 08:121121 1!11 I illS I 86 1 0: 1!10 01/08/86 12:J!H21 01/1218/86 14: 01!1 1211/1218/86 16:1ll!21 Ql:l. /1!18/86 18:121121 1211 n!l8/86 20:00 !!11 I !218/86 22: !210 BYTE RAW DATA ========== 21215 59 61 207 6i!l 62 209 58 60 211 56 58 213 58 60 215 54 55 217 57 59 219 58 60 221 55 57 223 55 57 225 56 58 227 55 57 DAILY AVERAGE VALUES 229 55 56 231 55 57 233 54 56 235 55 56 237 55 57 239 54 56 241 54 56 243 54 56 245 53 55 247 53 55 249 54 56 251 51 53 DAILY AVERAGE VALUES 253 51 53 255 52 54 257 50 52 259 52 54 261 52 54 263 51 53 265 51 53 267 52 54 269 5121 52 271 52 54 273 54 55 275 5121 52 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 0.9 1. 0 0.8 0.6 0.8 0.4 0.7 0.8 0.5 0.5 Y.l. 6 0.5 (11. 7 0.5 0.5 0.4 0.5 0.5 0.4 0.4 0.4 0.3 f2S. 3 121. 1 0.2 121. 121 fZI. 2 0.2 121. 1 0.1 Y.l. 2 0. fell 0.2 0.4 0.0 0.1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 1.1 1.2 1.0 k1. 8 1.0 0.5 0.9 1. 0 ~~. 7 Ql. 7 0.8 J!l. 7 0.9 ill. 6 ~~-7 0.6 0.6 V.I. 7 f21. 6 0.6 0.6 0.5 121. 5 0.6 0.3 !Zi. 6 121. 3 121. 4 0.2 0.4 0.4 ttl. 3 0.3 121. 4 0.2 0.4 e:s. 5 0.2 121. 3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- 1211 / 1!.19 /86 !ll0: Ql'-!1 Ql1 I 1219/86 1212: 1!10 1!11/1219 /86 Y-14: 0t!l Qll/ 1219/86 1!16: 1!11!1 1!11 /!.39 /86 IllS: 00 !!H I 1!19 I 86 1 Ill: 0f21 1211 I 1!19 /86 12 : !l10 !!11 11219/86 14:0£1 01 /1!19/86 16: 00 ~!11 I 1!19 I 86 18: 0!ll l!ll /09/86 20: (!10 l?ll I Ill 9 / 86 22 : 12H!I Qll I 11!1 I 86 1210: 01Zl i-!11/l!!l/86 1212:00 !!11 I 1 ~!l/86 r214: f2H21 01/1121/86 06:00 1!11 I HI l 86 1218: Y.h!l Jll111QI186 1fll!!l10 I2111H!I186 12:00 1!.11 I 1 Ill I 86 1 4: 00 !!11 I 11!1/86 16 : r21Y.:I 1211 I 10186 18: 1!.10 1211/1!!1186 20:!lli!l l!ll I 10186 22:00 1!11 I 11 /86 121121: 12l!i.l 1211/11186 02:121!21 (211111186 04:00 Ill! I 11 186 1216: r210 !!11 I 11/86 Y.l8: 00 Ql1 l 11 I 86 10: I!IIZI Y.l 1 I 11 I 86 12: 121121 1211 I 1 1. I 86 14: l!ltZI !!.11 I 11/86 1 6: ~;;0 !lll/11186 18:0!ll Y.HI11186 20:00 !!11 / 11/86 22: I!Ht.l BYTE RAW DATA ========== 277 54 56 279 54 56 281 53 55 283 52 54 285 54 55 287 5121 52 289 48 51 291 50 53 293 48 50 295 48 50 297 49 51 299 48 50 DAILY AVERAGE VALUES 301 50 52 31213 54 56 3U15 48 5121 307 52 54 31!19 54 56 311 51 54 313 52 54 315 52 54 317 51 54 319 52 54 321 54 55 323 50 52 DAILY AVERAGE VALUES 325 51 53 327 53 55 329 49 52 331 51 53 333 52 54 335 49 52 337 52 54 339 53 55 341 52 53 343 53 55 345 55 56 347 52 54 DAlLY AVERAGE VALUES CHAN 1 DEG C. ------------ 0.4 0.4 0.3 0.2 0.4 121. 0 -0.2 0.0 -0.2 -0.2 -121.1 -0.2 0.1 Ql. 0 0.4 -0.2 0.2 0.4 121.1 0.2 0.2 0.1 0.2 0.4 0 .. f2! 0.2 0.1 Ill. 3 -0.1 121. 1 0.2 -{{1. 1 0.2 0.3 0.2 ~1. 3 0.5 0.2 0.2 DATA FILE : RIFFLE01 START: 12128185 12:00 STOP: 04/08186 18:00 CHAN 2 DEG C. ------------ 0.6 0.6 0.5 121. 4 0.5 Ill. 2 0.1 Ill. 3 0.0 121. 0 0.1 0. 1!1 1!1. 3 0.2 0.6 0.0 0.4 121.6 f21. 4 0.4 (ll. 4 0.4 £1.4 0.5 121. 2 121. 4 0.3 f21. 5 0.2 IZI. 3 1!1. 4 0.2 0.4 121. 5 0.3 Ill. 5 !?.l. 6 0.4 Ill. 4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-~1.1 DEG C TEMP/TEMP RECORDER Page 6 12-Y-12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- li.ll/12/86 ~Zll'ZI:V.Il21 '!H I 12 I 86 1!!2: IZH!i ~!) 1/ :t :-:'' ~:.:; 6 )(.14 ~ l2i~i 1211 .. :1 ;j o6 1!i6: !!dZi t.:~i 1 / 1 ~ .. / .:.Jt.; ~:~j f3; Q)ti: !i.i 1 / l ,;;: / 6:S 1 ~) : Q}!!l i~l i / .12 / 86 12 : i!H!i li.i 1 / 12/86 l 4 : i!l\!l iZll/12/86 16: 00 i/.!1 I 12/86 18: l!i~l !-!il /1.2/86 :2!21: j;~lQl \Zll/12/86 22~l!.l!'.j ;:;; l ' :1. ::;/ ·::•o !2i~i ~ ifH~; ::~;J i }.3/86 Qj2: ~~JQ! r!i 1 / 1 :::,: 8c:· i~;4 ~ i!@ iii i /1 ~'·l 86 i!:i6 ~ 1Zls<) :{1 J. / 1 J / d~-1 Ql8 ~ ~llli lj) :l / 1 :, .. / d6 1 Qj ~ 12ii21 ~~; ~ / J :_;,I b·b 1 2; illii.i (;jl /14/86 0li:1: 00 i2i 1/14186 1!12: 0121 J!H /14 I 86 f2i4 : 00 Qil / 14/86 1!16: !Zl0 !!H/14186 08:00 12!1 I 14 I 86 1 !l~: !21!21 1211/ 14 / 86 12: 0!21 i!ll/14/86 14:!lll21 flll I 1 4 /86 16: 00 ~~j 1/14/86 18: 0121 !211/14186 20:0!21 ~il1114/86 22: !llj{.l BYTE RAW DATA ==== ========~::= 34'7' ~):;. 55 .551 55 ~·6 ~-c. .. --:~ ._ • .._}.._1 -.r ! .. ":' r;: ...:~...J ... J 52 54 54 56 359 5t2i 53 :361. 55 57 363 57 59 365 54 55 367 57 59 ::>69 58 6C.:i 3'71 55 57 DAILY AVERAGE VALUES :::73 58 6i2l 3'75 59 6.1 ::7'7 57 59 :379 57 6111 ::.~G 1 58 6121 ~58:3 ~j6 58 ~;9). ;::;, I ;:;,1(; .: ·:; .~. 58 6~1 395 56 58 DAILY AVERAGE VALUES 397 57 59 399 58 60 401 57 59 403 58 6~1 4Y.l5 58 6!!1 407 57 59 409 58 60 411 59 61 413 58 6121 415 6!.!1 61 417 60 62 419 58 61 DAILY AVERAGE VALUES CHAN 1 DEG C. ----·····~--·- ____ .. __ 0.1 0.4 Ql. V.l 0.5 Ill. 7 (21* 4 l!l. 7 Ql. 8 Y-l. 5 ii.J. 4 e1. a 0.9 !Zi. 7 f:J. ' Ill. Q i!!. 6 !(;. b J!l, 6 0.7 0.f! 0.6 0.7 0.7 0.8 0.7 {21, 8 0.8 0.7 f2l. 8 0.9 0.8 1.0 1.0 es. 8 0.8 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04108/66 18:00 I.:;HAl~ 2 DEG <~;. --·--·~ .. ------- !21. 5 i!l. 6 l!i. 4 Y.l. 4 0.6 !21. :~. Ill. 7 l!i. 9 ~~-5 !!J. 9 1. Ql 121. 7 Qi. 6 1.1 !i.l. '7 1. ;l"i 1:!. 8 !ll. 8 Ql. 8 0.8 121. 9 1. 0 0.8 0.9 '"'· 9 1. Ql 0.9 1. 0 1.0 !ll. 9 1. 0 1.1 1. 0 1.1 1. 2 1.1 1. !Zl ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== !211 I 1 5/86 IZH!l: 0!21 i!ll/151 86 1!12: QI!Zl J!ll I 15/86 1!14: 0121 1!11 I 1 5 I 86 1216: 1210 12!1 I 15186 08:00 01/15/86 1121: (!1121 01115/86 12:0121 01 I 15186 14: 01!1 01115/86 16:00 01 I 15 I 86 18: !21121 Y.H/15/86 2121:0121 l!f 1 I 15/86 22: I21S!I 1211 l 1 6 I 86 1211!1 : !!1121 iZil/16186 02:0!ZI t!11 I 16186 1214: I!H21 01 I 16/86 1216:0121 Qll I 16/86 ~~8 : 121121 Ql1 /16/86 10:00 S!ll I 1 6 I 86 12: 0121 1!11 / 16 I 86 14: 00 01116186 16:!211!1 IZH /16 I 86 18 : 1!10 01116186 2121:1.!1!21 1211/16/86 22: 1!10 1-::11. / 1 7 i 86 IZI0: 121121 01117186 1212:121121 01 I 17/86 04:1210 i!ll / 1 7 I 86 1216: 1!1111 1!11 I 1 7 I 86 1218: 121!:!1 01 I 1 7 I 86 11!1 : 121!21 1211 I 17186 12: I!J0 1!11 I 17186 14: 1211!1 ~; 1/17/86 16: l21!!1 i!l1 I 1 7/86 18: 0121 s!ll I 17186 2.121:00 i!'ll I 17/86 22: !!1121 BYTE 421 423 425 427 429 431 433 435 437 439 441 RAW DATA ========== 59 61 61!1 62 59 61 59 61 59 61 59 61 59 61 59 61 58 6fll 60 62 61 63 443 59 61 DAILY AVERAGE VALUES 445 57 59 447 59 61 449 56 58 451 57 59 453 57 59 455 56 57 457 55 57 459 56 58 461 55 56 463 55 56 465 55 56 467 54 56 DAILY AVERAGE VALUES 469 51 53 471 54 55 473 49 51 475 48 51 477 49 51 479 48 5~1 481 48 50 483 48 51 485 48 50 487 49 51 489 49 51 491 48 51 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 121. 9 1. !ZI 121. 9 1.!1. 9 0.9 121. 9 0.9 121. 9 IZI. 8 1. f2l 1. 1 1!1. 9 0.9 121. 7 0.9 0.6 121. 7 121. 7 0.6 0.5 0.6 0.5 0.5 0.5 0.4 0.6 0.1 121. 4 -f2J. 1 -0.2 -0.1 -0.2 -0.2 -121. 2 -121. 2 -121. 1 -121. 1 -121. 2 -0.1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04108/86 18:00 CHAN 2 DEG C. ------------ 1.1 1. 2 1. 1 1.1 1.1 1.1 1. 1 1.1 1 • 121 1.2 1.3 1.1 1.1 0.9 1.1 0.8 0.9 12!.9 121.7 0.7 121. a 0.6 jll. 6 0.6 0.6 121. 8 Ill. 3 0.5 0. 1 0.1 0.1 0.0 0. 121 l!l. 1 !!I • 1!1 0. 1 0.1 0.1 1!1. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- 01 / 18 I 86 (M!l: 01.!1 01/18/86 1.!12:1!1!!1 01/18/86 1214:!!10 !!11 I 18/86 !!16: Qlfc!l QJl/18/86 08:0121 k11 I 18/86 10:1210 f211 I 1 8 I 86 12: !!10 1211 /1 8/86 14 : 121€1 !211 I 18/86 16: f2IQI 01/1 8 I 86 18: 1.!11.!1 1211 I 18/86 20:00 Qi 1/18/86 22: Y.ll!l 01 I 19 I 86 121111: 121121 1211 I 19/86 !.:!12: 1210 01/19/86 1214:0121 1211/1 9/86 1-!16: 00 m 1 / 1 9 /86 1218: 12H!I ~!11/1 9 I 86 1U1: 00 1211 I 1 9 I 86 12: 121121 ~~11 / 19 I 86 14: !!IJ21 f211 I 1 9 I 86 1 6 : ll!!ZI Qll/19/86 18: 00 1!11/1 9 I 86 2~<:1: 121121 01/19/86 22!k1121 01120/86 tZH!I: 1210 !!11 I 21!1 /86 f212: 0121 1211/2!!1 /86 1214: s!l0 t!ll I 2ill /86 IZ16: !21!!1 1211/2121/86 1218:00 !!11120/86 10:~1l!! 1!11 /2!!1/86 12: !!10 !!11/2!21 /86 14: 0121 121112121/86 16:0121 I!H /2ft.l I 86 18: '21!!1 1211/2!21 I 86 2121: 1210 IZ!l I 2!!1 /86 22: 1!1121 BYTE RAW DATA ========== 493 49 51 495 49 51 497 48 5121 499 48 5121 501 48 51 503 48 50 505 49 51 507 51 53 51219 48 5121 511 52 54 513 52 54 515 5121 52 DAILY AVERAGE VALUES 517 51 53 519 52 54 521 50 52 523 52 54 525 52 55 527 51 53 529 52 54 531 52 55 533 52 54 535 53 55 537 53 56 539 52 54 DAILY AVERAGE VALUES 541 52 54 543 54 55 545 51 53 547 51 53 549 52 53 551 50 52 553 49 51 555 50 52 557 48 51 559 48 51 561 49 51 563 48 51 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -0.1 -121. 1 -0.2 -121. 2 -0.2 -0.2 -0.1 0.1 -121.2 "'· 2 Ill. 2 121. 1!1 -0.1 0.1 0.2 0.0 0.2 1!1. 2 1!1. 1 0.2 0.2 V.I. 2 fZI. 3 0.3 0.2 0.2 !21. 2 0.4 0.1 fZI. 1 0.2 121. 0 -0. 1 -0.2 -121. 2 -0.1 -V.I. 2 0.0 DATA FILE : RIFFLE01 START: 12/28185 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 121. 1 QJ. 1 121. 0 0.121 0.1 f21. 121 121. 1 0.3 121. 0 121.4 0.4 0.2 0.1 0.3 1!1. 4 0.2 0.4 0.5 0.3 0.4 121. 5 !.:1. 4 0.5 0.6 Ql. 4 !i.l. 4 0.4 121. 5 0.3 0.3 121. 2 121. 1 1!1. 2 0. 1 0. 1 121. 1 1!1. 1 0.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- ~211/21 / 86 1!10: Ql~l m 1/21/86 1!12; !211!1 ~11/21 I 86 !!14: !21!21 01121186 1216:0121 !211/21186 08:121fZI 01/21186 11!1: 0121 01121/86 12:00 01 I 21/86 14: 0121 1!11 121/86 16: fll0 !!11/2 1/86 18: !'210 1211121/86 20:(10 Ql1 /21/86 22: !!S0 ~31/22/86 121121: 0!21 1!11122/86 02:00 ~o1 122/86 1!14: ese1 ~Sl/22/86 1216:121121 1211/22186 08: 121121 1!11 /22186 1as: 00 !!11 122/86 12: 01Zl 01/22/86 14: f2l0 01/22/86 16: 01!1 1211122/86 18: !ZIY.l V.l1 I 22/86 2!21: 1!11Zl Y.l1 122/86 22:00 Y.il/23186 !!1121: 121121 1211/23/86 !212: !!l!ZI 01123186 1214: 1!10 01123/86 1216:0121 01/23/86 08:00 1211 / 2 3 I 8 6 l!ZI : 121!!1 1211123/86 12: 0~1 ~!11 123186 14: 1211!1 1211/23/86 16:1210 !!fl/23186 18: Y.JI!I !!11/23 /86 2!!1: 121!21 (?il/23/86 22: !2iQI BYTE RAW DATA ========== 565 48 51 567 48 51 569 48 50 571 48 51 573 49 51 575 48 5121 577 50 52 579 52 53 581 48 50 583 52 53 585 52 54 587 50 52 DAILY AVERAGE 589 50 52 591 5121 53 593 49 51 595 50 53 597 52 54 599 49 52 601 52 54 61213 52 54 605 52 54 607 53 55 6~19 53 55 611 52 54 DAILY AVERAGE 613 52 54 615 53 55 617 51 53 619 5121 52 621 51 53 623 5121 52 625 50 52 627 50 53 629 50 52 631 51 53 633 52 54 635 49 51 VALUES VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -0.2 -0.2 -0.2 -0.2 -121. 1 -0.2 0.2 -{l1. 2 Ql. 2 0.2 0.0 -0.1 Ill. 121 0.0 -1.!1. 1 0.0 0.2 -0.1 0.2 0.2 0.2 0.3 0. 1 0.2 121.3 0.1 0.0 0.1 {!1 • Ill 1!1. 121 Ql. 121 0.0 121. 1 0.2 -0.1 0.1 DATA FILE : RIFFLE01 START: 12/28185 12:00 STOP: 04108186 18:00 CHAN 2 DEG C. ------------ 0.1 121. 1 Ql. 0 0.1 121. 1 0.0 121. 2 tll. 2 Ill. 3 0. 1 £1. 3 0.4 tll. 2 0.4 0.4 0.4 Ill. 5 0.5 0.4 0.3 0.4 0.5 0.3 l!l. 2 !111. 3 0.2 0.2 0.3 0.4 t!l. 1 121. 3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page HI 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 1211 /24 I 86 121!!1: ~~1121 !Z!l 124/86 !!12: 0!21 1!11 124186 ~14: 0QI !211 /24186 !.!16: !!1121 1!11 /24186 1218: llll!l !211124/86 lfll:i.!li!l ull/24186 12: a1ro !Zl1124/86 14: 121!!1 1211124/86 16:00 !211/24/86 18: 00 01/24186 21!1: 0!!1 l!ll 124186 22: flH!l 1211 I 25/86 llHZI: 1.!1!!1 !211 125186 02:00 !Zll./25/86 1214:1!10 01125186 06:0121 !!11/25186 IZIB: !!1121 01/25/86 ll!l: 0121 1211125/86 12: 121121 lll1 / 25/86 14: 00 01/25/86 16: 1!10 Ql 1125/86 18: @~I i!ll/25/86 21!1: 1210 !lll /25186 22: !ll0 1211/26186 0!21: !210 1!11 I 26186 !212: 121121 01/26186 04:00 1!11 I 26/86 !216: 121121 S.H /26/86 !218: ~!IQI !!11/261 86 1121: !!lltl 01/26/86 12:00 i!ll/26/86 14:121121 !!11 I 26/86 16: Ill~!! 1!11/26/86 18: 121!21 01 /26/86 20: Y.I!ZI !!ll 126/86 22: 1!1!21 BYTE RAW DATA ========== 637 52 54 639 52 54 641 52 54 643 52 54 645 52 55 647 52 54 649 52 53 651 52 54 653 51 53 655 51 53 657 52 54 659 51 53 DAILY AVERAGE VALUES 661 50 52 663 52 54 665 48 5121 667 48 51 669 49 51 671 48 5121 673 48 5121 675 49 51 677 48 51ZI 679 48 50 681 49 51 683 48 5i!l DAILY AVERAGE VALUES 685 48 5121 687 49 51 689 48 5121 691 49 50 693 49 5!21 695 48 5121 697 48 51ZI 699 49 51 71111 48 50 71213 48 51 7!215 49 51 71217 48 51!1 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 121. 2 121. 2 0.2 121. 2 0.2 Ql. 2 0.2 121. 2 Ill. 1 0.1 111.2 121. 1 0.2 {21. 121 0.2 -Ill. 2 -0.2 -0.1 -Ill. 2 -Ill. 2 -0.1 -!21. 2 -121. 2 -!21. 1. -0.2 -121. 1 -121. 2 -j!l. 1 -0.2 -1!1. 1 -0.1 -!21. 2 -121.2 -0. 1 -121. 2 -0.2 -0.1 -121. 2 -V.I. 2 DATA FILE : RIFFLE01 START: 12128185 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 0.4 0.4 121. 4 !21. 4 0.5 0.4 121. 3 0.4 0.3 0.3 0.3 0.4 0.4 0. fll 121. 1 !0. 1 0.0 0.0 0.1 0. 121 121. 121 IZI. 1 Ill. 121 121. 1 121. 0 0.1 121. !21 IZI. 0 0.0 121. tt1 0.0 0.1 0.0 0.1 0. 1 0.0 Ill. !!I ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TH1E -------------------------- 01/27/86 i1.l0:121fZl 1211 /27/86 !212: 01!1 t.H /27/86 04: 1.!10 i?H/27/86 06:@21 !!11 /27/86 f!l8: 0(1 !!11 I 27 I 86 HI: l!l!ll (11/27/86 12:00 V.ll I 27 I 86 14: flllll 1211/27/86 16! 00 l!ll/27/86 18:V.l!21 01/27186 20:t!l0 i211 I 27186 22: !!1!21 !!11 /28186 00: Ql!ZI Qll I 28186 !212: !lll!l 01128/86 1214:!!1121 !!11/28/86 06:0121 1!11 I 28186 08: 0121 1211/28/86 10:00 01128/86 12:!21121 01128/86 14:00 iZil /28/86 16: !21!21 12l1 /28/86 18: 1210 Y-11/28/86 2121:1210 01/28/86 22:£210 01/29 I 86 IZII21: 1210 1211 I 29 I 86 fll2: 121QI Qll 129/86 1214:00 1?11/29/86 !216:01!1 !!11/29186 l218:Jllf21 !!11 I 29 I 86 1!!1: f!IIZI 1211129/86 12:00 !!11 /29/86 14: 121!21 !!11 /29/86 16: l!HZI l!ll/29/86 18:0!21 fl1129/86 20:QI1,!1 !211 I 29/86 22: 1211!1 BYTE RAW DATA -------------------- 709 48 51 711 49 51 713 48 51 715 49 51 717 49 51 719 48 5121 721 48 50 723 48 5fZI 725 48 5121 727 48 5121 729 48 5121 731 48 5121 DAILY AVERAGE VALUES 733 48 51 735 48 51 737 48 50 739 48 51 741 49 51 743 48 50 745 48 50 747 49 51 749 48 5121 751 48 5121 753 48 51 755 48 5!21 DAILY AVERAGE VALUES 757 48 50 759 48 51 761 48 50 763 48 51 765 49 51 767 48 51!1 769 48 51 771 49 51 773 48 5fi.l 775 48 51 777 48 51 779 48 5121 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ -!21. 2 -121. 1 -1!1. 2 -0.1 -0.1 -~1. 2 -121. 2 -IZI. 2 -0.2 -0.2 -0.2 -0.2 -0.2 -0.2 -0.2 -~1. 2 -Ill. 2 -i!l. 1 -0.2 -Ill. 2 -121. 1 -~1. 2 -Ill. 2 -0.2 -0 .. 2 -0.2 -0.2 -0.2 -0.2 -0.2 -0.1 -121. 2 -0.2 -0.1 -0.2 -121. 2 -121.2 -Ill. 2 -121. 2 DATA FILE : RIFFLE01 START: 12128/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 0.1 0.1 fl. 1 0.1 (21. 1 !21. !!1 0.0 121. 0 Ill. 0 Ql. 0 0. IZI 0.121 0. Ill 0.1 (21. 1 121. (!I ~~. 1 121. 1 0.0 0.121 0.1 0. Y.l 121. 121 0.1 0.0 0.1 0.0 0.1 0.0 fll.1 121. 1 0.0 0.1 1'0.1 0.0 0.1 0.1 121. Ill 0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 12 12-1212~87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== fll l/3f!l I 86 !!1121: 01!1 !211 I 3QJ /86 !212: !!1!!1 !!11/30186 lll4: !!10 !ZI 1 / 3!21 /86 1!16 : 1Zif21 Y.ll/3~21/86 1218: 0~1 !Ell I 31!1/ 86 11!1: fZIIZI Qll I 30/86 12: 1210 iZ!l/3!21/86 14: 0!21 1!11 /3f!l/86 16: 0121 1!11/3!21/86 18:1210 1211130/86 2!21: !!10 ~:11 /3121/86 22: 1!10 121 1 I 31 I 86 IlliZI: 0121 {211131186 02:00 0l. I 31 I 86 1214 : !210 01/31/86 06;00 IZI 1 I 31 I 86 08 : f210 1211/31/86 H1: 0f2l !!11 I 31 I 86 12 : 0121 f2ll I 31 I 86 1 4! f210 !!11 /31/86 16: !!1!21 !.!11 /31186 18! f2SQI !211/31/86 2121: IlliZI f211 /31/86 22: !!1121 !212/1!11/86 Y.ll!l: 00 Ql2/1!11 /86 02: 01ZS 1!12 /IZI1 /86 04: t2H!l ~!12/illl 186 1216:00 Qi2/!2il/86 Y.l8:01!1 Ql21!2il/86 UZI: 1211!1 1212/ ~11/86 1 2: 0121 !!12/IZil /86 14:121121 1212/1211 /86 16: 1210 12!2/!211/86 18:QH21 1!12/1211/86 2121: 1!11!1 ~12/ !!11/86 22: 1!1!21 BYTE RAW DATA ==== -------------------- 781. 48 51 783 49 51 785 48 50 787 50 52 789 52 54 791 49 51 793. 52 54 795 54 55 797 51 53 799 55 56 81211 55 57 81213 54 55 DAILY AVERAGE VALUES 805 81217 809 811 813 815 817 819 56 57 57 59 54 56 56 58 57 59 55 57 54 56 56 57 821 53 55 823 53 55 825 54 55 827 53 55 DAILY AVERAGE VALUES 829 52 54 831 54· 55 833 50 52 835 49 52 837 50 53 839 49 51 841 5121 52 843 51 53 845 49 51 847 54 56 849 57 58 851 51 53 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -IZI. 2 -1!1. 1 -121. 2 !.!1. Ql 0.2 -V.I. 1 1!1. 2 121. 4 0.1 0.5 0.5 fll. 4 0. 1 1"21. 6 0.7 0.4 1!1. 6 fll. 7 0.5 0.4 0.6 0.3 l!l. 3 0.3 !2f. 5 ~~-2 121. 4 0.0 -0.1 0.0 -0.1 0. J!l 1!1. 1 -121. 1 0.4 Ill. 7 121. 1 0.1 DATA FILE : RIFFLE01 START: 12/28185 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 0.1 fll. 1 1!1. 0 1!1. 2 1!1. 4 !Zl. 1 0.4 0.5 0.3 121. 6 ~~-7 f21. 5 ~~-3 0.7 0.9 0.6 0.8 0.9 0.7 0.6 0.7 0.5 0.5 i!l. 5 Ill. 5 0.7 fell. 4 121. 5 0.2 0.2 0.3 0.1 0.2 Ql. 1 0.6 0.8 Ill. 3 0.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 13 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME .. ..,._______ ------------------ IJS2/!Zl2/86 0121:1210 1212/1!12/86 1212: !!10 Ql2/W.l2/86 04:0121 !!12/1212/86 !.!16: QliZl !2!2/02/86 1218: 1!.1!!1 !!12/1212/86 1!21:1210 !li2/Y.I2/86 12:00 !212/02/86 14: 0!2! 02/02/86 16:00 !212/02/86 18: fll0 02/1?.12/86 20:00 i!l2/V.12/86 22: 1211!1 ili2 I !213 /86 !!l!!i: 1210 QI2/QI3/86 02:0121 iZI2/03/86 1!14: 00 1212/!213/86 1216: 00 i212h213/86 08: 0!21 1!!2/ 1!13/ 86 1121: 01!1 02/1213/86 12:0121 Y.l2/lt.l3/86 14:121121 12121!213/86 16: f2ll2l !2!2/03/86 18:00 12!2 / i!l3 I 86 2121: ~1121 1!12/03/86 22:00 02/£14/86 012!: 0121 !!'2/1214/86 1!12: !210 !!J2/.~l4/86 04:0121 1(12/1!14/86 06: 0!21 !!12/1214/86 1!18: 0(!1 i!l2 I 04/86 10: 121121 1212/1214/86 12: !21121 !212/ 1214/86 14: 0121 1212/04/86 16:00 ~Z!2/iZ14/86 18: 1!11!1 1212/1(.14/86 2121: !211Zl 1!12/!i.14/86 22: 1:!1121 BYTE RAW DATA --------------------853 58 60 855 59 61 857 56 59 859 58 6!ZI 861 59 61 863 58 6121 865 58 6121 867 59 61 869 56 59 871 57 59 873 58 61 875 56 58 DAILY AVERAGE VALUES 877 55 56 879 56 58 881 53 55 883 51 53 885 53 55 887 49 51 889 49 51 891 5~1 52 893 49 51 895 51 53 897 51 54 899 50 52 DAILY AVERAGE VALUES 901 52 54 9!213 52 54 905 50 52 907 52 53 91!19 52 54 911 51 52 913 51 53 915 51 53 917 5121 52 919 52 54 921 52 55 923 51 53 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== !21. 8 0.9 0.6 121. 8 0.9 0.8 0.8 ~1. 9 0.6 fll. 7 0.8 0.6 0.8 0.5 0.6 0.3 0.1 0.3 -0.1 -121. 1 0.0 -0.1 0.1 0.~ 0.0 l!S. 1 Ill. 2 0.2 0.0 0.2 12J. 2 0.1 0.1 0.1 0.121 ill. 2 W.2 !!1. 1 0.1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 1. 121 1.1 !21. 9 1. 121 1.1 1. l!l 1. 0 1.1 0.9 0.9 1.1 0.8 1.0 t:Zl. 6 121. 8 0.5 fll. 3 0.5 0.1 0.1 !2J. 2 121. 1 0.3 l!l. 4 fZI. 2 !21. 3 0.3 0.4 Ill. 2 0.3 0.3 ~~-2 0.4 0.5 fll. 3 121. 3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 14 12-1!12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== 1212/£15/86 !!1121: 0121 1212/05/86 !l12: 0121 1212/1215/86 1214: i!llll 1!!2/05/86 1216:121121 s!l2/l!l5/86 1!18: !!10 !'212/1215/86 1 !ZI: !210 02/05/86 12: !ll0 02/1215/86 14:0121 1212/t-!15/86 16:0~1 1!12/05/86 18:0121 Y.I2/QI5/86 20:0121 V.12/05/86 22:1210 02/1216/86 1!10: 0~1 02/fll6/86 l212: 00 1!12/!216/86 04: V.10 !ll2/!216/86 1!16: 00 1!12/1!16/86 !218: !210 rc!l2/06/86 10: 00 !!12/1!16/86 12:0121 1212/1216/86 14: 00 Ql2/1216/86 16:12H21 02/06/86 18:0121 02/1216/86 20:1210 1212/06/86 22:0121 1212/!!17 /86 01!1: 00 !212/07 /86 1212: 12l!ZI 1!12/1217 /86 1214:0121 02 I 1!17 I 86 !216: 121121 1212/ !217 /86 1218: 0121 i212/!!l7 /86 1!21: 1!1121 1212/07/86 12:00 !l12/1217 I 86 14: 0f21 l212h37 /86 16:1210 1212/!.117 /86 18:121121 02/1217/86 2~~= 00 1!12/!217/86 22: 1211!1 BYTE RAW DATA ========== 925 50 52 927 52 55 929 48 51!1 931 48 51 933 48 51 935 48 51!1 937 48 50 939 48 51 941 48 50 943 49 51 945 51 54 947 48 50 DAILY AVERAGE 949 951 953 955 957 959 961 52 54 53 55 51 53 54 56 56 57 53 55 56 58 963 57 59 965 55 57 967 57 59 969 58 6!21 971 56 58 DAILY AVERAGE 973 58 60 975 59 61 977 57 59 979 59 61 981 60 61 983 57 59 985 56 58 987 58 6!ll 989 55 57 991 56 58 993 58 6121 995 55 56 VALUES VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 0.0 0.2 -0.2 -121. 2 -0.2 -0.2 -0.2 -0.2 -0.2 -0.1 0.1 -0.2 0.2 0.3 121.1 0.4 !21. 6 0.3 0.6 0.7 0.5 0.7 0.6 0.6 121.5 0.8 0.9 0.7 121. 9 1. 121 0.7 0.6 0.8 0.5 121. 6 0.8 0.5 0.7 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== l!l. 2 0.5 121. Ql ~~. 1 0. 1 0. f21 0.0 0. 1 yj. !21 121. 1 !21. 4 0.0 !Zl. 1 121. 4 0.5 0.3 ~1. 6 121. 7 0.5 fZI. 8 0.9 0.7 0.9 1.0 0.8 0.7 1.a1 1.1 0.9 1.1 1.1 121. 9 121. 8 1.0 121. 7 121. 8 1. 0 V.I. 6 0.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 1!12/08/86 01!1: 00 02/1218/86 1!12: !211!1 Ql2/!218/86 !214: !t.IY.I !212/08/86 !!16: 121121 02/1218/86 1218: 1!1121 !212/1!18/86 1r21: lifl!l 1212/1218/86 12: ~10 I212/IZI8/86 14: f21l!l 02/08/86 16:00 02/1218/86 18: 1210 1212/1218/86 20:00 1212/!218/86 22: 1!10 Y.l2/l!l9/86 1!10:0!21 1!12109/86 1212:0£1 $!12 I 09 I 86 1!14: I!I!ZI £12/1219/86 06:00 1!12 / !219/86 !218: 00 0211219186 10:0!21 1!12/~19/86 12: 00 !212 / 9.19 I 86 14: 0!21 ill2/09/86 16: 121!21 1212/1219186 18:00 1!12 I 1219186 2121: 1211!1 1!12109/86 22:1210 !212/ 1121186 1211!1: 00 1!121 1!21/86 02: 1!10 t!l21 lf!l/86 1114:.00 !!12/ llll/86 !216: 1!1Y.1 1!12/ 11!!186 08:00 1212/ Hl/86 1121:00 Ql2/ lQI/86 12:00 1212/ Hl/86 14: l!I!ZI 02/1121/86 16:121!!1 lll2/ Hl/86 18: 01ZI !?.12/ Hl/86 2111:00 1!12 I 1 Q! I 86 22: 121121 BYTE RAW DATA ========== 997 57 60 999 58 60 112101 57 59 11211213 57 59 1005 58 6!21 Hl07 57 59 101219 57 59 1011 58 61 1013 57 59 112115 59 61 1017 59 61 1fcH9 58 60 DAILY AVERAGE VALUES 1021 58 60 U2123 59 61 11!125 57 59 li2127 57 59 1029 58 612> H!131 57 59 1121~.3 57 59 1035 58 61 11ll37 57 59 1 !2139 6121 62 1041 62 64 1 ft!l43 59 6!21 DAILY AVERAGE VALUES 1045 62 64 Hi47 62 64 11.!149 61 63 1!2151 61 63 1053 62 65 11.!155 61 62 1057 63 65 112159 65 66 Ull61 62 64 1S!I63 67 68 1!!165 68 71.11 1!!167 65 66 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 0.7 !21. 8 0.7 0.7 0.8 (2~. 7 0.7 0.8 0.7 0.9 0.9 Ql. 8 0.8 0.8 !!! • 9 Ql. 7 0.7 0.8 !21. 7 0.7 0.8 1!1. 7 1 • &21 1.:2 0.9 0.8 1.2 1.2 1.1 1.1 1. 2 1.1 1. 3 1.5 1.2 1.7 1. 8 1.5 1. 3 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 1.0 1. !21 121. 9 r.!l. 9 1.0 Ill. 9 ~~-9 1.1 0.9 1.1 1.1 1. !!1 1.0 1. Y.l 1.1 0.9 0.9 1.0 0.9 0.9 1. 1 !2~. 9 1.2 1.4 1.0 1. IZI 1.4 1.4 1.3 1. 3 1. 5 1.2 1.5 1.6 1.4 1.8 2.0 1.6 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- Y.l2 I 1. 1 I 86 !211!1: !211!1 1212/11186 1!12: Y-1!21 ~!!2/ 11186 !Zl4: 1!10 1212 I 11 I 86 1!16: Y.l!ll 1?.12/ 11/86 08: 1211!1 1!12/ 11186 HI: 121!21 1212111186 12:00 1!12/11186 14:1210 1212111186 16: 01ZI 12121 11 186 18: IZII!I 02111/86 2!'ZI: 00 1212111/86 22:0121 02112186 !2S!ll: 1210 1212/12186 02: Qlfll !212112186 !214:121121 02/12186 1216:0121 1!12 I 12/86 08: 11!10 02112/86 HI: f210 1!12112186 12:121121 9.12112/86 14:00 1!12 I 1 2 I 86 16: 0!21 1212112186 18: 1210 1212 I 12 I 86 2121: 1(1121 1212/12/86 22:1210 1212/13186 !210: 1210 12121 13/86 02: 121121 02113186 04:tc10 1212113/86 1216 :til0 1!!21 13186 1218: 00 !!12 I 13 I 86 1!!1: 121121 1212/13/86 12:00 1!12113186 14:121121 1!12/ 13/86 16: !210 1!121 13/86 18: 121!21 ~212/ 13186 2i21: 0121 ~12/13/86 22: 1211!1 BYTE RAW DATA ========== lfll69 63 65 1071 67 69 1f2173 61 63 11!175 61 63 11/J77 62 64 112179 60 62 1081 59 61 112183 60 63 1085 58 60 112187 63 65 1089 65 66 112191 59 61 DAILY AVERAGE 112193 61!1 62 112195 64 66 1097 56 59 1099 55 57 111!11 57 59 1103 54 56 1105 53 55 1107 54 55 1HI9 52 54 1111 55 56 1113 57 59 1115 53 55 VALUES DAILY AVERAGE VALUES 1117 55 57 1119 57 59 1121 53 55 1123 52 54 1125 54 55 1127 52 54 1129 52 54 1131 52 55 1133 52 54 1135 54 56 1137 57 59 1139 52 54 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 1. 3 1.7 1.1 1.1 1.2 1. !21 Ill. 9 1. f21 0.8 1. 3 1.5 0.9 1.2 1.121 1.4 Ill. 6 Ill. 5 121. 7 0.4 0.3 0.4 fll. 2 0.5 0.7 0 .. 3 0.6 0.3 0.2 0.4 0.2 1'21. 2 0.2 121. 2 0.4 Ill. 7 0.2 0.4 DATA FILE : RIFFLE01 START: 12/28185 12:00 STOP: 04108186 18:00 CHAN 2 DEG C. ====== 1. 5 1.9 1.3 1. 3 1. 4 1.2 1. 1 1. 3 1.0 1.5 1.6 1.1 1.4 1.2 1. 6 Ql. 9 0.7 121. 9 0.6 0.5 Ill. 5 121. 4 0.6 (21. 9 0.5 r!l. 8 121. 7 es. 9 ilf. 5 0.4 0.5 1!1. 4 0.4 ~~-5 Ill. 4 0.6 0.9 l!l. 4 Ql. 6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-!212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 1212/14/86 ~10: !21!21 Ql2/ 14/86 1212: iZH!l 1212/14/86 ~!14: 1.!10 02/14/86 !l16: 00 J.ZI2/ 14/86 08: lll!ll 132/14/86 10:{21!.!1 1<!12/14/86 12:!210 1!12/14/86 14:121121 !212/14/86 16: 00 !212/14/86 18:l!IY.I 02/14/86 2!21: 00 !212/14/86 22:1210 1!12 / 15/86 1!1421: 121121 1212/15/86 f-12: 121!21 iZI2/ 15/86 04: 0f21 1!12/15/86 06:1210 1!12/ 15/86 08:0121 1212/15/86 10:00 1!12/ 15/86 12: 00 1212/15/86 14:12H21 1!12/ 15/86 16: !llk1 1212/15/86 18:!2H21 i212/ 15/86 2fil: iZ10 !212/ 15/86 22: ltJI21 1212/16/86 !21!21:00 fll2/ 16/86 fZI2: IZH!I £$2/16 I 86 1214: 121121 02/16/86 V.16: !!Ill! 02/16/86 1218: !21121 !!12/16/86 1 !21: iZIQI !212/16/86 12: 121!21 1212/ 16/86 14: 121121 J-32/16/86 16:00 1!12/ 16/86 18: V.li!l Ql2/16/86 2!21: 1210 V.i2/16/86 22: fbQI BYTE RAW DATA ==== -------------------- 1141 55 56 1143 57 59 1145 52 54 1147 51 53 1149 52 54 1151 50 52 1153 49 51 1155 50 52 1157 49. 51 1159 52 54 1161 55 56 1163 50 52 DAILY AVERAGE VALUES 1165 1167 1169 1171 1173 1175 1177 1179 1181 1183 53 55 55 56 52 54 5121 53 52 54 49 52 49 52 50 52 49 51 50 53 1185 52 54 1187 49 51 DAILY AVERAGE VALUES 1189 5l. 54 1191 53 55 1193 5C!1 52 1195 50 52 1197 50 53 1199 49 52 1201 50 52 1 21213 51!l 52 12!215 49 51 121!17 49 51 121219 50 52 1211 49 51 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ Ill. 5 !21. 7 121. 2 121. 1 0.2 0. J'ZI -Ill. 1 0.i!l -0.1 0.2 0.5 0.0 0.2 Ill. 5 0.2 0.0 Ill. 2 -121. 1 -0.1 0.0 -0.1 0. 121 121. 4 -0.1 !21. 1 1<!1. 1 0.3 0.0 !21. 0 0.0 -121. 1 Ql. 121 121. 0 -0.1 -!21. 1 Y.l • 121 -Ill. 1 0.0 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 0.3 0.4 0.2 0.1 121. 2 0.1 Ill. 4 0.6 !21. 2 !21. 4 0.5 Ql,. 6 Ill. 4 121. 3 121. 4 0.2 0.2 0.2 0.1 0.3 0.4 Q!. 1 0.3 Ql. 4 121.5 0.2 0.2 11.1. 3 !!1. 2 0.2 V.I. 2 Ql. 1 0. 1 1!1. 2 !21. 1 121. 2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 18 12-I!S2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME --------------------------- 1!12/1 '7 /86 fZi!Zl: 0121 1212/17/86 1212: fli!Zl 02/17/86 1!!4: 00 02/17/86 1Zi6: 0121 '=!12/17/86 1218: 12.10 Ql2/17/86 1121:1210 1212/17/86 12:00 02/17/86 14:00 !.212/1 7/86 16:1210 02/17/86 18:121121 9.12/17/86 2el: 00 !2!2/ 17/86 22: 12H2l 1212/18/86 12112.1:1210 !Zl2/18186 02:k10 !!12/ 18186 04: 1!1121 1212/18/86 f216!01ll 1!12118/86 1218:fll!21 02/1.8/86 10:12.1!i.l Y-12/18/86 12:0121 02/18/86 14: 0'=!1 02118/86 16: !!lfli 1212/18/86 18:1210 1!12/18/86 2121:121121 f-32/ 18186 22:00 1212 I 1 9 I 86 121121: Qh!l J£!2/1 9/86 QJ2: fi!lll 1212/19/86 1214:00 1212/1 9/86 06: 00 02/19/86 !218: 00 !!12/19/86 10:1!10 1!!2/19/86 12: 01~1 Ql2 / 19/86 14: l!lt!l iZ12/19/86 16:00 1212/19/86 18: IZII!l Y.S2/l9/86 2!!1:0121 Ql2119186 22:121~1 BYTE RAW DATA ========== 1213 50 53 1215 52 53 1217 49 51 1219 49 51 1221 50 52 1223 49 51 1225 49 51 1227 49 51 1229 48 51 1231 49 51 1233 49 52 1235 49 51 DAILY AVERAGE VALUES 1237 49 51 1239 49 51 1241 48 51 1243 49 51 1245 49 51 124 7 48 5121 1249 49 51 1251 49 51 1253 48 51 1255 49 51 1257 49 51 1259 49 51 DAILY AVERAGE VALUES 1261 49 51 1263 49 51 1265 48 51 1267 49 51 1269 49 51 1271 48 5121 1273 49 51 1275 49 51 1277 48 51 1279 49 51 1281 49 52 1283 48 51 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 121. 0 0.2 -121. 1 -!21. 1 0.0 -121. 1 -0.1 -0.1 -0.2 -0.1 -ti!l. 1 -Ill. 1 -0.1 -0.1 -0.1 -121.2 -0.1 -0.1 -0.2 -0.1 -0.1 -0.2 -121. 1 -121. ~ -0.1 -0.1 -121. 1 -0.1 -0.2 -0. 1 -0. 1 -f!l. 2 -0.1 -0.1 -121.2 -1!1. 1 -~1. 1 -1!1. 2 -121. 1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 1!1. 3 0.3 Ill. 1 0. 1 0.2 {21. 1 1!1. 1 0. 1 121. 1 £!1. 1 !ZI. 2 0.1 QS.2 fll. 1 121. 1 121. 1 0.1 0.1 0.0 121. 1 0. 1 0.1 0.1 0. 1 121.1 121. 1 0.1 121. 1 0.1 '=!1. 1 0.1 0.f21 0.1 0. 1 0.1 V.I. 1 0.2 0. 1 0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 19 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE ·---------------- TIME ===== 02/ 2'!1 /86 l!li-!i: !21Y.I !?.12/2!21186 1212: 121!21 1!12/21!1/86 Ql4: !Zlt!l Y.l212!ZI/86 06:121121 1212/ 21!ll 86 Ql8: ~!IJt.! i212 I 21!1 I 86 1£!1 : 0k!l ll12/21lU86 12:1210 1!12/2!21186 14: 1!1121 02/20/86 16: k!l0 l212/2t!l I 86 18: IlliZI Y.!2/2!Zl/86 20: !210 1212/21!1 I 86 22: l!IY.I 1!12 I 21 I 86 IZlf!l: !210 1!12121/86 1212:00 iZl2 I 21 I 86 ~l4 : fil!Zl 1212/21186 1216:121121 1!12/21/86 1218: IllY.! !212 /21 I 86 llll: 1210 1252/21186 12:!211!1 {(12121/86 14:1210 !!12121/86 16: !!liZ! Y.i2121/86 18:0121 1?.12/21186 2t~l:012l l!l2121 /86 22: 0!ZI $212122/86 !210: 1210 !!12122/86 02: i!HZI 1212/22186 1214: !ZI~l 1212/22186 !216: i!IQl )(.12/22186 1!18: fZIQI Ql2/22/86 HI: 1!1!21 1212/22/86 12: !210 !!12122186 14: i2H2l 1-!12/22/86 16: QIQI !2!2/22/86 18: !210 1!12/22/86 20:1210 i!i2/22/86 22: 1!10 BYTE RAW DATA ========== 1285 49 51 1287 49 51 1289 48 51 1291 49 51 1293 49 51 1295 48 51 1297 48 51 1299 49 51 131211 48 50 131!13 49 51 1305 49 51 131217 48 51 DAILY AVERAGE VALUES 131219 49 51 1311 49 51 1313 48 50 1315 48 51 1317 49 51 1319 48 5121 1321 48 51 1323 49 51 1325 48 50 1327 49 51 1329 49 51 1331 48 50 DAILY AVERAGE VALUES 1333 49 51 1335 49 51 1337 48 50 1339 48 5121 1341 49 51 1343 48 5!ZI 1345 48 51 1347 49 51 1349 48 5!21 1351 49 51 1~;53 49 51 1355 48 51!1 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -Ill. 1 -!!1. 1 -Iii. 2 -0.1 -0.1 -0.2 -121.2 -as. 1 -lt:i. 2 -!21. 1 -0.1 -0.2 -0.1 -Ill. 1 -Ill. 1 -0.2 -0.2 -0.1 -Ill. 2 -0.2 -0.1 -0.2 -0.1 -0.1 -0.2 -121.2 -0.1 _,,_ 1 -121.2 -0.2 -0.1 -121. 2 -0.2 -0. 1 -0.2 -!21. 1 -1.!1. 1 -1!1. 2 -0.2 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04108/86 18:00 CHAN 2 DEG C. ------------ 0.1 !21. 1 1!1. 1 {!1. 1 0. 1 !21. 1 ~~-1 121. 1 !21. 0 121. 1 121. 1 0.1 0.1 Ill. 1 0.1 121. 0 0.1 0.1 0.0 0.1 0.1 0. 1.!1 1!1. 1 0.1 Ill • !ZI 121. 1 V.I. 1 0.1 121. 0 121. 0 f£1. 1 121. 0 Ill. 1 0. 1 121. 0 0.1 0.1 Ill. Ill 0.1 f. I! i21 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2121 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- Q!2/23/86 1?.1121: 0121 1212/23/86 1212: 1211!1 1212/23/86 1214:00 i!l2/2::.>186 !216: !21!21 !212/23/86 !218: 1210 !212/23/86 1121: !21121 1212/23/86 12:00 1212/23/86 14: !21121 02/23/86 16:00 1!12/23/86 18: 1211!1 lo2/23/B6 20: 1210 1!12/23/86 22:121121 1212/24/86 !li!!i: 1~121 1212/24/86 1112:0121 1212/24/86 1214:0121 w:./24/86 1216: 121121 Q:,L/24/86 !218: Y.I!ZI !212/24/86 10: !210 1212/24 I 86 12: 121!21 !212/24/86 14: !!llii !212/24/86 16:121121 ~12/24/86 18:00 i!i2/24/86 21!1: 1!1!21 ~12/24/86 22: !2iY.i 1!12/25/86 !21!21: 121!21 1212/25/86 1!12: !21121 !212/25/86 04:1210 1!.12/25/86 1216: tMi 1212/25/86 !218: 00 1!12/25/86 10: l!li!l !212/25/86 12: 1210 1212/25/86 14: !!i!Zi !212/25/86 16: 00 ~12/25/86 18: !!i!Zi ~:12/25/86 2121: !21121 1212/25/86 22: i!l!!l BYTE RAW DATA -------------------- 1357 48 51 1359 49 51 1361 48 50 1363 49 51 1365 49 51 1367 48 51 1369 49 51 1371 49 51 1373 48 51 1375 49 51 1377 50 51 1379 48 5lZI DAILY AVERAGE VALUES 1381 48 51 1383 49 51 1385 48 5!21 1387 48 51 1389 49 51 1391 48 51 1393 49 51 1395 49 51 1397 48 51 1399 49 51 141!11 49 51 1403 48 51 DAILY AVERAGE 1405 49 51 1407 49 51 141219 49 51 1411 49 51 1413 49 52 1415 49 51 1417 49 51 1419 5!ll 51 1421 49 51 1423 49 51 1425 49 52 1427 48 51 DAILY AVERAGE VALUES VALUES CHAN 1 DEG C. ------------ -0.2 -0. 1 -0.1 -121. 2 -0.1 -0. 1 -0.2 -121. 1 0. Qi -0.2 -0.1 -l!l. 2 -0.1 -!Zi. 2 -0.2 -0. 1 -0.2 -0.1 -0.1 -0.2 -0.1 -0.1 -0.2 -0.2 -0.1 -0. 1 -0. 1 -0.1 .-0. 1 -0. 1 -Ill. 1 0. 121 -0.1 -!21. 1 -!21. 1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 1.11. 1 Ill. 1 121. !21 1!1. 1 1!1. 1 1!1. 1 0. 1 121. 1 1!1. 1 e1. 1 0.1 121. 1!1 0.1 0. 1 121. 1 0. 121 121. 1 0. 1 121. 1 0. 1 f.(l. 1 121. 1 0.1 121. 1 121. 1 1!1. 1 !21. 1 1!1. 1 0.1 0. 1 0.2 0. 1 0. 1 121. 1 0. 1 !21. 1 !21. 2 {!1. 1 lc!l. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 22 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- fi.~3/!!ll /86 Q!QI; Qi0 l!l3/J211 /86 i!i2: 1?11!1 ~l3/!lll/86 !!14:01!1 i!l3/!!ll I 86 !216: 12ifi.l 03 I £EH I 86 fc':l8 : 1210 l!i3 I !!I 1 / 86 liZI: l!H~l 1213/01/86 12:1210 !213/Y.il /86 14:00 03/fiH /86 16: !210 V.l3/!211/86 18:1210 03/i:H /86 2121:00 1!13/f!il /86 22: f!ll2i !213 I 1212/86 f!il!i: !21!21 03/!212/86 1!12: !210 !CI3/02/86 1214: f!ifll !!13/1212/86 ~>6: 121!21 1!13/1212/86 fZI8: Y.l!ll f!l3/f!l2/86 HI: fc!10 !213 I 1!12 I 86 12: Qlf21 03/1212/86 14!00 1!13/1212/86 16: 01Zl !ll3/Y.I2/86 18: t?l0 ~!13/ Ql2/86 21!1: Ql{21 ~:!3/!212/86 22: 0QI 03/1!'3/86 l2lf2l:l!l0 P-13/!ll3/86 !212: V.HZI 1?.13/03/86 04: l()fll 03/1213/86 !216: 01!1 !213103186 v.ss: 1!1121 1!13 I !213 I 86 HI: 1211!1 !Zi31f213/86 12:00 QJ3/l!l:3/86 14: 121121 !213/!!13/86 16: 1211!1 !!13/Y-13/86 18: 1211a 1!13/1!13/86 2121: Q.ll21 QS3/f!l3/86 22: tll!!l BYTE RAW DATA ==== ========== 151211 49 51 15!ll3 49 52 15iZ15 48 51 151!17 51!1 52 1509 50 52 1511 49 51 1513 5Y.I 52 1515 50 52 1517 49 51 1519 49 51 1521 49 52 1523 48 5fll DAILY AVERAGE 1525 49 51 1527 50 51 1529 48 51 1531 49 52 1533 5121 52 1535 49 51 1537 49 51 1539 50 52 1541 49 51 1543 49 51 1545 49 51 1547 48 50 DAILY AVERAGE 1549 48 51 1551 49 51 1553 48 50 1555 49 51 1557 49 51 1559 48 51 1561 49 51 1563 49 51 1565 48 51 1567 48 5121 1569 49 51 1571 48 51!1 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ------------ -Ill. 1 -Y.I. 1 -1!1. 2 1!1. Ill 121. 0 -0. 1 (21. Ill -0.1 -0.1 -Y.I. 1 -!21. 2 -0.1 -{21. 1 !21. 0 -!ZI. 2 -0.1 0.0 -0.1 -!ZI. 1 ~~-121 -fZl. 1 -121. 1 -121. ~ -0.2 -121. 1 -Ill. 2 -0.1 -0.2 -121. 1 -121. 1 -121.2 -IZl. 1 -1!1. 1 -0.2 -0.1 -QI. 2 -0.2 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 0.1 {21. 2 0.1 0.2 121. 2 0.1 0.2 0.2 0.1 0.1 121. 2 Ill. Ill 9.1. 1 121. 1 ~~-1 0.1 0.2 0.2 0.1 0.1 !21. 2 121. 1 0.1 0.1 0.0 0. 1 121. 1 121. 1 0.0 0.1 !21. 1 !21. 1 0.1 121. 1 0.1 0.0 121. 1 !21. 1!1 0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 23 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== !21~.5/1214/86 (!10: m~Zs fZI3/04/86 1212: !!1!21 1!13/!!14/86 {214: 0121 QI3/IZ14/86 lll6: 1211!1 ~93/ Qi4 I 86 1218: V.li!l 03/1!14/86 1121:0121 Y.l3/!:'114/86 12: 0QI 1?13/1!14/86 14: 121!ZI V.l3/ !214 I 86 16: 0!21 ~13/ 1!14 /86 18: 1!1!21 1213/1!14/86 2121: 121!21 !213/1!14/86 22: 1!1121 03/1215/86 1211?.1: 121121 1213/1!15/86 02: 1211!1 1!.13/1!15/86 1!14: 121121 !li:3/ltl5/86 1!16: I(J!!I 1213/!215/86 1!18: !21121 1213/~!15/86 HI: !l10 1!13/1!15/86 12: fli!ZI 1213/1!15/86 14:00 l!r5/05/86 16: !21121 03/1!15/86 18: 1211!1 1213/1215/86 2121:121!21 1!13/!!15/86 22:1210 Ql3/l216/86 QIJ!I: 1!10 Ql3/l!i6/86 f2J2: 00 !ZI3/f!l6/86 1214: 01ZI 1!13/1!16/86 06:121121 l!I3/QI6/86 08:0121 1!13/1!16/86 11!1: 0121 1!1:3/1216/86 12: (,!lj.J.I 1213/!!16/ 86 14: ~!1121 1!13/s-:16/86 16: l(J0 ~!13 h!l6 /86 18: 1!1!ZI (!1:3/1!.16/86 2121: I!H!I Ql3NJ6/86 22: eh21 BYTE RAW DATA ========== 1573 48 51 1575 49 51 1577 48 5121 1579 49 51 1581 49 51 1583 49 51 1585 49 51 1587 50 51 1589 49 51 1591 48 50 1593 49 51 1595 48 5121 DAILY AVERAGE 1597 48 51 1599 49 51 1612H 48 50 1603 49 51 161!15 49 51 1607 48 51 161!19 49 51 1611 49 51 1613 49 51 1615 48 51 1617 49 51 1619 48 5l!l DAILY AVERAGE 1621 49 51 1623 49 51 1625 48 50 1627 49 51 1629 49 51 1631 48 51 1633 49 51 1635 49 51 1637 48 51 1639 49 51 1641 49 5l. 1643 48 51 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== -121.2 -!Zl. 1 -0.2 -121. 1 -0.1 -0.-1 -0.1 0. 1!1 -!!!. 1 -0.2 -0 .. 1 -Y.I. 2 -0.1 -0.2 -0.1 -0.2 -0.1 -fll. 1 -0.2 -0.1 -0.1 -121. 1 -0.2 -as. l -0.2 -!21. 1 -0.1 -1!1. 1 -~l. 2 -0.1 -0.1 -1!1. 2 -0.1 -0.1 -0.2 -V-i. 1 -0.1 -121.2 -121. 1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ fll. 1 Ql. 1 0. 121 !21. 1 es. 1 121. 1 0.1 l.iJ. 1 0.1 121. fli 121. 1 0. fZI 0.1 121. 1 0.1 0.0 0. 1 0.1 0.1 121. 1 0.1 121. 1 121. 1 0.1 121. 0 0. 1 0.1 l.!l. 1 0.0 121. 1 0.1 121. 1 0.1 !ZI. 1 0.1 0.1 !21. 1 0. 1 0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 24 12-lll2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- !!13/!217 /86 ~!10: QIQI ~213/1!17 /86 !212: flll!l Ql3/!!17 /86 Ql4: 00 l213 /1217 I 86 1216: QIQI es:::;.; ~<!17 186 ~!18: Y.II2S 1!131Y.l7 /86 11!1: !!1121 !213/!217 /86 12:00 1!13 I !217 I 86 14: 121121 lll3/!!!7 /86 16:00 S!l3/fll7 186 18:0121 1!!3/!217 /86 20: Ql0 !!l31Y.I7/86 22:0121 Qs:::;;lf!S8186 l!ls!J: 0121 ~33 l !ZI8 I 86 1!12: !21121 Ql3h!l8/86 1214:!21!21 Ql31QI8/86 1!16: 00 121311!18/86 1!18: f2SQI !213/08/86 HI: 1210 1!13/1218/86 12: !210 1!1311!18/86 14: !210 1213/ 1!18 I 86 16: Y.:J!21 Ql~5/!2l8/86 18: !210 l?.l31J!I8186 2!21: 121!21 1213/ 1218/86 2 2 : !ZIQI 03/1219/86 121!21: {21{21 !!13/1!19/86 02: !21Y.1 1213/fll9/86 1214: {210 1!13/ 09/86 1216: 0£1 1213/1219/86 1!18: f..ih;:l IZI3/Y.I9/86 U!l: {21121 12i3 I 1!19 /86 12: !!10 1!13/!219/86 14: i!l!lJ i213/i.iJ9/86 1.6: 01i!l l!l3/fZI9/86 18:1!1!21 03/1?.19/86 2!21: Ql0 !213/1219 /86 22: 121!!1 BYTE RAW DATA ==== -------------------- 1645 48 51 1647 49 51 1649 48 5121 1651 49 51 1653 49 5:!. 1655 48 51 1657 49 51 1659 49 51 1661 48 51 1663 48 5121 1665 49 51 1667 48 51!1 DAILY AVERAGE VALUES 1669 49 51 1671 49 51 1673 48 5!!1 1675 49 51 1677 49 51 1679 48 51 1.681 49 51 1683 49 51 1685 48 51 1687 49 51 1689 49 51 1691 48 5121 DAILY AVERAGE VALUES 1693 49 51 1695 49 51 1697 48 50 1699 48 51 1701 49 51 171!13 48 51 1705 48 51 171217 49 51 17QI9 48 5.0 1711 49 51!1 1713 49 51 1715 48 5li.l DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ -Ill. 2 t.-0. 1 -0.2 -0. 1 -0.1 -0.2 -0.1 -121. 1 -0.2 -{21. 2 -0.1 -121.2 -10.2 -0. 1 -0.1 -!!1. 2 -1!1. 1 -0.1 -0.2 -0.1 -0.1 -0.2 -0.1 -{21. 1_ -0.2 -121. 1 -QI. 1 -0.1 -0.2 -0.2 -.0.1 -121. 2 -0.2 -0.1 -0.2 -121. 1 -0.1 -s!l. 2 -0.2 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 0.1 121. 1 0.0 0.1 121. 1 es. 1 0.1 0.1 0.1 121. Y.l !21. 1 Ill. (ll 121. 1 (£1. 1 121. 1 121. 0 Ill. 1 0.1 !21. 1 0. 1 0.1 0.1 0.1 0.1 ~1. 0 Ql. 1 0.1 {ll. 1 121. 0 {21. 1 0.1 0.1 0.1 121. 1 0.0 0.0 0. 1 1!1. 0 0. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 25 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- t?i3i 1121/86 121121: Qll!i 1213/ Hi /86 !212: !21121 !213/ H1/86 !214: 00 1!131 Hl/86 1216: I!H2l ~:13/ Hl/86 08:1210 1!13/ 10186 !Ql: 121121 l2l31HI/86 12:00 Ql3/1!21/86 14:121121 1213/10/86 16:00 1213/1QII86 18:!21121 ~13110186 21!1:00 1213/ UZl/86 22: 121!!1 03 I 1 1 I 86 12@; l!il!l 1213/11186 02: 1210 l!13 / 11 I 86 ~14: fllfll 03/ 11 /86 1216: 121!21 i!13/11 I 86 1!18: 1!11!1 03/11/86 10: 01!1 1!13/11 186 12: 12l!21 1!13/11186 14:00 1!13/11 186 16: I!JIZI 1!13/11/86 18:00 l2i3 / 11 I 86 2121: 1!1!21 1213/11/86 22:1.!10 1!13/12/86 121121:00 i!l~$/12/86 02:1211ZI 1213/12/86 !Zl4: 00 1!131 12/86 06: 1211!1 03/12/86 1!18:1210 !ZI~S/ l. 2/86 1121: 12llll 1213/12/86 12:121121 ;,!13/12/86 14:1!1121 1!13/1.2186 16: Qlf21 11.13/12186 18: Qlfl iZl::;; i .2/86 212l: 0121 ~13/ 12/86 22:121121 BYTE RAW DATA ========== 1717 49 5121 1719 49 51 1721 48 5121 1723 49 51 1725 49 51 1727 48 5121 1729 49 50 1731 49 51 1733 48 50 1735 48 50 1737 49 51 1739 48 50 DAILY AVERAGE VALUES 1741 49 5121 1743 49 50 1745 48 51!1 1747 49 50 1749 49 51 1751 48 5121 1753 49 5121 1755 49 51 1757 48 5@ 1759 49 50 1761 49 51 1763 48 5121 DAILY AVERAGE VALUES 1765 49 50 1767 49 5@ 1769 48 50 1771 49 50 1773 49 5fi.l 1775 48 5121 1777 49 50 1779 49 51 1781 48 5!!1 1783 48 50 1785 49 51 1787 48 5121 DAILY AVERAGE VALUES CHAN 1 OEG C. ------------ -1!1. 1 -!Zl. 1 -0.2 -V.I. 1 -0.1 -1:4.2 -0.1 -121. 1 -0.2 -1!1. 2 -121. 1 -0.2 -0. 1 -0.1 -0.1 -121. 2 -0.1 -0.1 -0.2 -0. 1 -0. 1 -1!1. 2 -0.1 -0.1 -0.2 -es. 1 -0.1 -~1. 1 -0.2 -121. 1 -es. 1 -0.2 -0.1 -121. 1 -121.2 -0.2 -0. 1 -!Zl. 2 -0.1 DATA FILE : RIFFLE01 START: 12128/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== Ill. 0 0.1 0. Ql 0. 1 ~~-1 !21. l!l 0.0 121. 1 0.0 1!1. l!i ~l. 1 0. 1!1 0.0 e1. 121 0.0 as. 0 121. 0 {l1. 1 0.0 {21. Ill 0.1 e1. 0 0.0 121. 1 121. 0 !21. Y.l 0.0 {21. {21 0.0 0. e1 0.0 0. V.i es. 121 0.1 Ill. 0 Ql. l!i 121. 1 0. l!l 0.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 26 12-02-87 BRADLEY LAI<E HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 1!13/ 13/86 !211!1: 01!1 {!13/ 13/86 02: I!H!.I 1!!3/13/86 04:12H21 1!13/ 13/86 1216: Y.l0 1213/13/86 1218: 00 !213/ 13/86 H!l: 0!21 03/13/86 12:00 1213/13/86 14: 00 1213/13/86 16:0121 {!!3/13/86 18: 1~10 03/13/86 2!21: 121121 1213/13/86 22: !21121 1213/14/86 1210: 01!1 03/14/86 02:00 ~213/14/86 1214: 0121 03/14/86 06: 1!10 1!.13/ 14/86 1218: 01!1 1213/14/86 10:00 V.13/ 14/86 12: !ll!!l 03/14/86 14:1210 !!13/ 14/86 16:£10 (!13/14/86 18: 1.!1121 t!l3/ 14/86 2121: fliY.I 1213/14/86 22:0121 1213/15/86 00:00 !!13/15/86 !212: 1210 03/15/86 04:00 Y.:l3/15/86 1216: !211!1 !(.13/ 15/86 1218: ti!0 !!13/ 15/86 11!1: !!1121 1213/15/86 12:0121 1213/15/86 14: 01!1 1!13/15/86 16: 121!ZS !ZI3/ 15/86 18: !21121 1213/:1.5/86 20: !!10 !!13/ 15/86 22: t!ll!i BYTE RAW DATA ==== ========== 1789 49 5121 1791 49 5121 1793 48 5121 1795 49 50 1797 49 50 1799 48 50 1801 49 50 18(!13 49 51 1805 48 50 1807 48 50 18!219 49 51 1811 48 50 DAILY AVERAGE VALUES 1813 49 50 1815 49 50 1817 48 5121 1819 49 50 1821 49 51 1823 49 50 1825 49 51 1827 49 51 1829 49 50 183l. 49 5s21 1833 49 51 1835 48 50 DAILY AVERAGE VALUES 1837 49 50 1839 49 51 1841 48 50 1843 49 51 1845 49 51 1847 49 50 1849 49 51 1851 5121 51 1853 48 50 1855 49 51 1857 50 52 1859 49 51 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -0.1 -0.1 -0.2 -121. 1 -121. 1 -!21. 2 -0.1 -0. 1 -0.2 -0.2 -0.2 -0.1 -0. 1 -0.1 -0.2 -0.1 -0.1 -0.1 -0.1 -0.1 -121. 1 -0.1 -0. 1_ -0.2 -121. 1 -0.1 -121. 1 -0.2 -0.1 -0.1 -0.1 -0.1 0.121 -0.2 -0.1 0.121 -!21. 1 -0.1 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ====== 121. 0 0. 1!;1 !Zl. 0 Ill • Y.l 0.0 121. 121 0.0 0.1 121. 0 0. t21 0.1 0.0 0.0 0. (!I 1!1. 0 0.0 0.0 121. 1 i?l. 0 !21. 1 0.1 Ill. 0 0.0 0.1 1!1. 0 0. Ill 0.0 0.1 0. !21 0.1 0.1 0.0 lll. 1 0.1 !21. 0 121. 1 0.2 121. 1 0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 27 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 03/16/86 1!1121: Qli!l 1213/16/86 1212: !ZI!ZI 1213/16/86 1!14:0121 !!13/ 16/86 1216: 1!!1!1 03/16/86 1!18:00 !!13 I 16 I 86 l!ZI: !21121 1!13/ 16/86 12:0121 Q!3/ 16/86 14: 0!!1 Ql3/16/86 16:00 1!13/16/86 18:01!! !213/ 16/86 2!!1: 00 1213116/86 22: 121e1 Qi3/ 17/86 0!!1: 0!21 S!i3/17 /86 1212: 1!10 i!13/ 1 7 I 86 04: 121!21 Y-131 17/86 Q!6: 00 !Z13/ 17 I 86 IZ18: 0121 Ql3/ 17/86 10: 0121 03/17/86 12:1211!1 1213/17186 14!00 1!13/1 7186 16: Y.lf.!l 1213 I 1 7 I 86 1 8: 0i!l 1!13/ 17/86 21!1: 121121 Y-13/17/86 22:00 i!i3 I 18 I 86 QIQI: 1?.10 i!131 18186 !212: 1210 03/18186 04:!210 !213/18/86 06: Qlf21 03118186 !1.18:0121 !213118/86 Hl:i!l!.~l 1!1::~ I 18 I 86 12: 1211!1 l!i:::;;; 18 I 86 14: 121!21 Ql::S/18186 16:00 Y-1311.8186 18:121e1 1!13/18/86 2!2>: 0QI i!13/ 18/86 22: 121!21 BYTE RAW DATA ========== 1861 49 51 1863 51.!1 51 1865 49 51 1867 49 51 1869 49 51 1871 49 51 1873 49 51 1875 50 52 1877 49 51 1879 51!1 52 1881 51 52 1883 49 51 DAILY AVERAGE 1885 50 52 1887 50 52 1889 5121 52 1891 50 52 1893 51 52 1895 50 52 1897 51.!1 52 1899 51 53 191!11 50 52 1903 52 54 1905 52 55 191217 51 53 VALUES DAILY AVERAGE VALUES 19QI9 53 55 1911 53 56 1913 52 55 1915 53 55 1917 54 55 1919 52 54 1921 52 54 1923 53 55 1925 52 54 1927 53 55 1929 54 56 19~::.1 52 55 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -121. 1 0.0 -0.1 -f!l. 1 -0.1 -121. 1 -0.1 0.0 -0.1 121 • IZI 0.1 -~!1. 1 1!1. 121 i!l. 0 0. !21 0.0 121. 1 0.0 121. 121 0.1 !.!1. 121 0.2 121. 2 0. 1 0. 1 0:.3 0.2 0.3 121. 4 0.2 0.2 0.3 0.2 1!1. 3 1.!1. 4 Ill. 2 s21. 3 DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG C. ------------ 0.1 0.1 121. 1 0.1 121. 1 0.1 121. 1 Ql. 2 121. 1 Ql. 2 0.2 1!1. 1 1!1. 1 Ql. 2 0.2 0.2 0.2 QS. 2 Ql. 2 0.3 !21. 2 Ill. 4 121. 5 0.3 Ill. 3 0.5 0.6 0.5 es. 5 0.5 0.4 0.4 121. 5 Ql. 4 121. 5 Ill. 6 121. 5 0.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 28 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------·---------- !?13/19 /86 00: !210 1?.13/1'9/86 02: 121\!.l !!13/1 9/86 04: Y.l0 !!13/19/86 1216: l!HZI 1!13/19/86 Y.I8:Ql0 03/1 9 /86 HI: e1121 1213/19/86 12:0!11 Y-13/19/86 14:0121 03/:1.9/86 16:l:!lf..~. !!13/19/86 l8: 0r21 1213119/86 2121:0121 !!13 I 1 9 /86 22: !210 1213/21!1186 00:00 03/2!21/86 !212: 00 !!J3/2!!l/86 1214: flls!l !21312!!1/86 1216:00 Ql3/2!21/86 1218: fll!!l !l13/20/86 HI: 00 Ql3/21Zll86 12:1210 03/2l2l/86 14:00 !!13/20186 16: !21!2! iZl3/21ZI/86 18:1210 ~~13/21!1 /86 2121: 1!1121 1213/20186 22: fZif(J m31 21 186 1211!1: 01!5 Ql3 I 2 1 I 86 !212: 0!21 Ql3/21 /86 1214:1210 1!13121 186 1!16: 1210 1!13 /21/86 !!18: 0!!1 Y-!3/21 /86 1!!1: !21!21 11.13/21/86 12: 12!!{.1 Ql3/21 186 14: t!ll!l (!13/21186 16:0!21 !!13/21/86 18:0121 ~!13/21 /86 2121; Y.1ii.l !!13/21/86 22: l!!Ql BYTE 1933 1935 1937 1939 1941 1943 1945 1947 1949 1951 RAW DATA ========== 55 56 55 57 53 55 53 55 55 56 52 53 51 52 52 54 50 52 52 54 1953 53 55 1955 5121 53 DAILY AVERAGE VALUES 1957 1959 1961 1963 1965 1967 1969 1971 1973 53 55 54 56 52 54 52 53 54 55 49 51 50 51 50 53 49 5121 1975 52 54 1977 52 54 1979 50 53 DAILY AVERAGE 1981 52 54 1983 53 55 1985 52 53 1987 52 54 1989 53 55 1991 51 52 1993 51 53 1995 52 54 1997 50 52 1999 53 55 2Qil211 54 56 2!21!!13 51 53 VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ f!l. 5 lZl. 5 0.3 1!1. 3 Ql. 5 0.2 121. 1 0.2 0.0 0.2 12!. 3 0. Ql 121. 3 121. 3 0.4 0.2 0.2 0.4 -0.1 121.0 0.0 -V.I. 1 0 .., ..... 0.~ 0. 121 0. 1 0.2 0.3 .~t .., X'•"- 0.3 0.1 0.1 121. 2 j(.l. 121 0.3 121. 4 Q'l. 1 0.2 DATA FILE : RIFFLE01 START: 12128/85 12:00 STOP: 04108/86 18:00 CHAN 2 DEG C. ------------ Y.i. 6 !21. 7 121.5 V.I. 5 0.6 fll. 3 0.2 0.4 0.2 0.4 ~~-5 V.I. 3 1!1. 5 1.!1. 6 0.4 0.3 0.5 0.1 121. 1 0.3 Ill. 0 0.4 0.4 121. 3 0.3 Ql. 4 0.5 Ill. 3 0.4 0.5 12l. 2 0.3 fll. 4 0.2 0.5 1!1. 6 fii. 3 0.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 29 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME BYTE RAW DATA -----------------========== ------------- 12!3/22/86 !!'H!I: 0Q1 21!105 55 58 03/22/86 f!S2: l!IJ!I 20tZ17 56 59 1213/22/86 Ql4 : (!lf21 212109 54 56 1213/22/86 Y.l6: !!10 2QI1 1 54 56 1!13/22/86 08: 11.1~!! 21!113 56 58 f33/22/86 10:@21 21!115 52 54 03/22/86 12: 0~J 212117 51 53 iZ13/22/86 14: 121!21 2019 52 54 k!!3/22/86 l.6: k?0 ~:.t!i2l 5f!'S 52 1!13/22/86 18: !l.li·:· 2~!i22.~ 53 55 : .. ,._·./ ~~~2/86 L:J;~~: k'H~i ;If2i~25 53 55 •! .. -_:1/ ::~:?/66 :2:?: tM~l 2l~J27 51 53 DAILY AVEF<AGE • "'l .~; .. ~:t; / [-) {~) il!i,i: i!i~l 2!21.29 t::"r::-57 t<'J·~·· I ,,.}._} ~!.>::; /::::3/ f:)6 YJ::;·_ ~ )}.if.2J 212131 56 59 >.~l~~. / :;;:,~:. / b&.' ~?.54~ QlV.J 212133 53 55 }!13 /23/ f:36 Ql6: fMil 2f2j35 54 ~·6 ~~~s::/ 23/ s~, Qi8: 01!.! 2~~13.~7 56 ~)8 s~; :::, / 2. :::~ / i.~ 6 U::l~ ~!)k~~ :'2.~!;3c; r.::. .... , ~,.;;. L':' "":"' .J •• ;. ~:?1~5_,,... ~~::~5/ Be) 1 2~ (i,J ~ZI ~·:~!)4l :;;.) J. j!;:'l"'l -'.::.. ~l,J ._;. / ,)0 ~i. ~· ~ :.:~i ~{: 2!.D43 a:;. .. ..., 5-'~ .. :... ·~' .• \,..).t.... .. ... .. .. -. ,. ;:·:,c::o J .• ::,, ~ ~bf.:.j' ;2 ~;~~ .(.~ :::. 49 5l DAILY AVEFIAGE CHAN 1 DEG c. ====== !21. 5 Y.l. 6 J2!. 4 121. 4 0.6 ~!). ~. ..:.. !iJ. 1 !21. r\ ..:.. !1.1. iZi Ql. 3 ~!}. .• :.:. f!l. 1 VALUES 0. 3 \!.i. c.:.;· ....! 0. 6 Ql. ·-· f). 4 i2l. 6 D. .-, .r.:.:. IZl , 1 i~j" 2 -IZl. i VALUES '~j. -, . .:;, DATA FILE : RIFFLE01 START: 12/28/85 12:00 STOP: 04/08/86 18:00 CHAN 2 DEG c. ------------ 0. 8 0. 9 0. 6 ~!I • 6 !21. 8 Y..i • 4 ~!}. ._:. !!J. 4 1!1 • ..., J,. Ill. 5 !21. 5 Y.l. ::::. 0. c:-•-' \ll. I 0. (""-~· Qi. 5 0. 6 m. 0 w ('i. -:'!' ·-· 12i. 2 s.!~" 4 ~!i. 1 Ill. .:· ·-' r:l\ __ ,.:r~:.: ·· ~' FTl\'IC::F .. ; ~~t.iTHOh l T'r' -; E\'1P /S T .:.GE 3 TLJi:; I C:f:\ r·.:.ge:: ) G~1A REPOR1 FOR DATAPOD DP212 V6-G.l DEG C TEMP/TEM~ RECORDER i 2·-·~.~;~ -;3 .. 1 0~.~ FILl : RIFFLE02 .Fi ;·~. ~~ )J L.. ~:: ·l L. A l :: f:'· t·--l y· _t} F·! C; ~.:. r< fj "-~ t:: ~~~~ T START: 04/08/86 18!00 (,;:,1-·>.f,"F\ h!-.,c;.=::,:.,-F-\:JF'FLc::. r·.E.f::;C;-, STOP: 05129186 12:00 CHAN 1 CHAN '") ..... •-I!~' T I, ·~" ., J··-I !. l'!t:. BYTE RAW DATA DEG c. DEG c. ·-·-··· ······-......... ---.. ~---==== ========== ====== ====== ----- V.14 / lZi81 86 18: Ql!!l 1 48 5121 -l!i. 2 £!. Ql ~~i4/i2l8186 2JZl : V.I!ZI 3 47 49 -Qs. 3 -V.I. 1 QI41Y.I8/86 22: Ill~, 5 47 49 -0.3 -V.l. 1 DAILY AVERAGE VALUES -til. 3 -121. 1 Qi41~~i9 186 Qll21: 00 7 48 50 -:-0.2 0 .Ill ili4/!Zl9 /86 !Zl2: 01!1 9 48 5!21 -0.2 !21 • l!l ilJ4 I Ql9/86 04:00 11 48 51!1 -!21. 2 0.0 i!l411Zl9/86 06: IZHZI 13 48 50 -0.2 Ql. 0 !!14/ !!19 I 86 08:00 15 48 50 -0.2 121. 0 V.i41!2l9186 1 !9: !!lrll 17 48 49 -0.2 -!Zl. 1 1214 I 1!19 I 86 12:00 19 48 50 -0.2 0. 121 ~!14 I 1!19 I 86 14: @21 21 48 51!1 -0.2 0. Ql 121411219186 16: 1!11!1 ....,..,. 4-' 48 5Ql -!21. 2 Ql. 0 ~!!411219 186 18: 1210 25 48 50 -0.2 0.0 1214/1219186 20:00 27 48 49 -!21. 2 -0.1 1!14 I 1!19 I 86 22: 121121 29 48 49 -121.2 -121. 1 DAILY AVERAGE VALUES -fZI. 2 -0.0 iZ14 I H!l I 86 121!!1: 0!21 31 47 49 -0.3 -0.1 ti14/ Hl/86 !!12: QIQI 33 48 49 -0.2 -!21. 1 12!41 1121/86 Ql4: !!1!21 35 47 49 -!!1. ~ -0.1 1214/ Hll86 1!16: 1!11!1 37 47 49 -0.3 -Ill. 1 041HV86 1218: k1121 39 47 49 -0.3 -0.1 !::14/ 10/86 11!1: 0!!1 41 47 49 -l!S. 3 -~~-1 i2l41 Hl/86 12:0121 43 48 50 -ill. 2 0.0 Ql41 1121186 14:00 45 48 5121 -{25. 2 1!1 • 121 fll4/lflU86 16:00 47 49 51 -0.1 0. 1 1:!141 10186 18: 1!1!!1 49 49 5121 -0.1 121. 0 12141 Hl/86 2121 : l!l!ll 51 48 50 -121. 2 0. !ZI ~!14/ Hl/86 22: 121121 C'..,. .J~' 48 5121 -121. 2 0.0 DAILY AVERAGE VALUES -121. 2 -!(!1. 0 04/1.1/86 Qlltl: 1(.)0 55 48 49 -{21. 2 -0.1 Q!4/11186 1212: 0Ql 57 48 5!!1 -0.2 121. 121 !214/ 11/86 04: 0f{.l 59 48 5121 -0.2 0.0 !!.14/11 /86 !216: 121!21 61 48 5121 -0.2 121. 0 04/11186 1!18: 00 63 48 49 -0.2 -0.1 ~!14/11186 1 !!l : 121 Ill 65 48 5121 -121.2 421 • i!l 12i4/11/86 12: 1210 67 49 51 -0. 1 Y.l. 1 1214/11 186 14: 0!21 69 49 51 -121. 1 121. 1 1214111 /86 16: 121!!1 71 51!1 51 0 .l!l IZI. 1 !!14/11/86 18: 121121 73 50 51 12! • 121 0. 1 1214/ 11186 2121:00 -rr:::: ,...., 49 51 -0.1 Ql. 1 V.l41 11186 22: I!IQI 77 49 5121 -121. 1 0.0 DAILY AVERAGE VALUES -~!!. 1 0.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== f!l4 / 1 2 I 8 6 !21121 : 121121 04/12186 !!12: 1210 !214/12/86 1214:00 1214112/86 1.!16: !211!1 1.':14/ 12/86 08:00 Ql4 I 12 I 86 1f21: 1!11!1 04112/86 12:1210 !!14/12/86 14:0121 04112/86 16:00 lo4/ 12/86 18:1210 !Zl4/ 12186 2121: 0QI !214/ 12/86 22: 1210 !214 I 13 I 86 0!21: l!l!ZI 04/13186 1212: 00 04/13/86 ~14: 00 !!14 / 13/86 06: !ll0 !!141 13/86 08:1210 1214 I 13186 ltll: 00 Y.i4/ 13/86 12: 1!10 04/13/86 14:L'J0 04/13/86 16; 0121 !214/ 13/86 18: !210 !!14/13/86 2121:00 1!14/13/86 22:00 1214/1.4/86 00:00 !!14 I 14 I 86 f212: 1211.!1 04/14/86 04:00 !~4 I 14 I 86 06: 00 ~14 I 14/86 IllS: 00 !!14/ 14/86 11!1: 0121 04/14/86 12:1210 1!14/ 14/86 14: 12!121 !214/ 14/86 16: !21121 1!14/14/86 18:1!11!1 !!14/1 4 I 86 21!1 : 0!21 1!14/14/86 22:121!!1 BYTE RAW DATA -------------------- 79 49 50 81 49 5121 83 49 5121 85 49 5121 87 49 5121 89 49 51 91 50 52 93 51 54 95 52 54 97 52 54 99 51 53 101 51 53 DAILY AVERAGE VALUES 1 !213 51?1 53 105 50 52 1U17 50 52 1fll9 51 52 111 51!1 52 113 50 53 115 51 54 117 52 55 119 53 56 121 54 56 123 53 56 125 53 55 DAILY AVERAGE VALUES 127 54 56 129 54 56 131 55 57 133 54 56 135 54 56 137 54 57 139 55 59 141 57 61 143 58 60 145 58 6!21 147 58 61 149 58 60 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== -0.1 -0.1 -0.1 -0.1 -121. 1 -0.1 0.0 1!1. 1 121. 2 121. 2 121. 1 0.1 0.0 !21. 0 0.0 0. Ill 0.1 121. 121 0.121 !.!1. 1 0.2 0.3 0.4 v.s. ~ 0.3 0.1 0.4 0.4 0.5 0.4 0.4 0.4 121. 5 0.7 0.8 1!1. 8 0.8 121. 8 0.6 DATA FILE : RIFFLE02 START: 04/08/86 18:1210 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====::::= 0.121 0. (21 1!1. Ql 12S. 0 0.0 0. 1 0.2 121. 4 0.4 0.4 121. 3 t'X "') "'""'" 0.2 0.2 0.2 121. 2 0.3 0.4 0.5 0.6 0.6 121. 6 0.5 121. 4 !21. 6 0.6 0.7 0.6 0.6 121. 7 0.9 1. 1 1. 121 1 • f2S 1.1 1. (!) 0.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-1:!12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 1214/15/86 IZif!l: 00 !!14/15186 !:!12: !!1!21 04/1 5 I 86 !!14 : 01.!1 04/15186 1216: J!ll2f 041 15/86 1218: 0121 1!14/15186 1121: 0QI 04 / 1 5/86 12: QSfll !!14/15/86 1 4: 00 04115/86 16:00 !214/15/86 18:01!1 04115186 20:00 1214115/86 22: 1210 1!14/16186 1210: 1!10 04116186 1212:00 1214116186 1!14: 01!1 04/16186 1216: 00 Y-14 I 16 I 86 1218: 1211!1 1214/16186 10:00 (!141 16186 12:00 1214116186 14:00 04116/86 16:1210 04116186 18:00 104/16186 20: Ql0 1214/16/86 22: Qlf() 1!14/17/86 1!10: 00 04117/86 1212: 012! 04117/86 1!14: 00 04117/86 1216: 00 04/17/86 t!S8:12H~I 041 17186 1 Ql: 121~1 0411.7/86 12:00 1!14/17/86 14: Ql0 1!14/1 7 I 86 1 6: 00 !!14/17/86 18: llHo J!i4/1 7 /86 2fll : f2i0 i!l4/17/86 22:1!1121 BYTE RAW DATA ==== ========== 151 58 60 153 58 59 155 57 59 157 56 58 159 55 57 161 55 57 163 56 58 165 57 59 167 57 60 169 58 60 171 58 6121 173 58 60 DAILY AVERAGE VALUES 175 58 61 177 59 61 179 58 61 181 58 60 183 58 59 185 58 60 187 59 63 189 62 66 191 63 67 193 64 67 195 64 67 197 64 67 DAILY AVERAGE VALUES 199 64 67 21211 63 65 203 62 63 205 59 61 207 59 60 21.!19 59 60 211 61 64 213 64 68 215 65 68 217 65 68 219 65 67 221 65 67 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 0.8 121. 8 Ql. 7 121. 6 0.5 121. 5 0.6 0.7 0.7 i!l. 8 0.8 121. 8 0.7 0.8 0.9 0.8 0.8 0.8 ,II. 8 Ill. 9 1. 2 1. 3 1. 4 l.Jt 1.4 1.0 1.4 1. 3 1. 2 0.9 0.9 !!S. 9 1.1 1.4 1 .. 5 1.5 1.5 1.5 1.3 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05129186 12:00 CHAN 2 DEG C. ====== 1. 0 Ql. 9 0.9 0.8 0.7 iZI. 7 0.8 0.9 1. 0 1. QS 1 • llS 1. !!I 0.9 1.1 1. 1 1. 1 1. 0 0.9 1. 0 1. 3 1. 6 1.7 1. 7 1. 7 1.7 1. 3 1. 7 1.5 1. 3 1.1 1.0 1.0 1. 4 1. 8 1.8 1.8 1.7 1. 7 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPDD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== !214/ 18/86 0121:1210 1!>4/ 18/86 (!12! Y.I!ZI 1214/18/86 1!14:00 iZ14/ 18/86 06: IZI!!I 1!14/ 18/86 !218: !210 Y.l4/18/86 Hl:f2H!I 04/18/86 12:00 '!14/ 18/86 14: IZIIZI 04/18/86 16:00 Ql4/ 18/86 18: 01!1 04/18/86 20:00 04/18/86 22: (!10 1!14 I 1 9 I 86 !21!21 : 121!21 Ql4/ 19/86 !'212: 00 !214 I 19/86 04: 12112! 1:!14/19/86 06:0lll !214/ 19/86 1218:00 1!14/19 186 10:00 1!141 19186 12: 1210 !214/19186 14:1210 Q14119186 16:1210 04119186 18:00 ~!14 I 1 9 I 86 2~!1: l21lll 1:!14/19186 22:£1f21 !214/20186 0!21: 00 121412!21/86 1212:100 0412!21186 04:00 1!1412121186 1!16: 00 1!14/21!1 /86 1218: 00 !!1412!!1186 1121:00 1!14 I 21!11 86 12: 0121 !214/2!!1/86 14: 0121 1!14/20186 16: 01!1 !!14121!1/86 18: Ql{:!l !?.14121!1/86 2121: 0i!l 9.14/2121/86 22: I!IIZI BYTE 223 225 227 229 231 233 235 237 239 241 RAW DATA --------------------65 67 64 65 61 62 59 59 57 58 58 59 60 63 61 65 62 65 63 65 243 62 64 245 62 64 DAILY AVERAGE VALUES 247 61 63 249 59 60 251 58 58 253 56 56 255 54 55 257 55 57 259 57 61!1 261 59 62 263 6121 63 265 6121 63 267 60 62 269 60 62 DAILY AVERAGE VALUES 271 59 60 273 57 57 275 55 55 277 53 53 279 52 52 281 52 54 283 55 58 285 58 61 287 59 62 289 6121 63 291 59 62 293 59 61 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 1 1::" .o.J 1.4 1.1 !21. 9 0.7 IZI. 8 1.0 1. 1 1.2 1. 3 1.2 1.2 1. 1 1.1 0.9 0.8 0.6 0.4 0.5 0.7 121. 9 1. IZI 1.121 1.12! 1.0 121.8 0.9 0.7 0.5 121. 3 Ill. 2 0.2 !21. 5 0.8 0.9 1. {21 1:'.1. 9 121. 9 121. 7 DATA FILE : RIFFLE02 START: 04108186 18:00 STOP: 05/29186 12:00 CHAN 2 DEG C. ====== 1.7 1. 5 1.2 1!1. 9 0.8 {21. 9 1. 3 1.5 1. 5 1.5 1. 4 1.4 1. 3 1. 3 1.0 0.8 0.6 0.5 k:l. 7 1. !ZI 1.2 1. 3 1.3 1.2 1. 2 1. Ill 1.0 0.7 0.5 0.3 0.2 0.4 0.8 1.1 1. 2 1. 3 1.2 1.1 0.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-IZ12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 04 I 21/86 121(!1: f!iQI 1!14/21 /86 1!12: 0121 !!14/21 /86 U14: 0!!1 i214 I 21/86 1:!16: l!ll!l !214/21/86 1!.~8: 01!1 f!l4/21/86 10: IZJC.!I 1!~4/21/96 12:00 04/21/86 14:!21f.!l 04/21/86 16:0121 1!14/21/86 18:00 !214/21/86 2121:!210 1!14/21 /86 22: Ql!Zl ~14/22/86 121~1: 0!ll 1214/22/96 V.12: 0'j (!14/22/86 1.":14: Y.IJ!I 1:!14/22/86 1216: 1210 V.54/22/86 !Zl8: 1!5121 1!14/22/86 10: Qlf21 !!14 I 22/86 12: !2!121 !!14/22/96 14: l!J!25 ~!14/22/86 16: 1!1!21 04/22/96 19: 0!21 1!14/22/86 2121: 0QI 1214/22/86 22:00 !!14/23/86 00: 01ll 1214/23/86 Ql2: Ql!ll 1!14/23/86 Y.l4: 00 04/23/96 1216:00 1214/23/86 Y.IS: 00 i!14/23 /86 1 121: lll!ll !214/23/86 12: (!10 ~!14/23/86 14: !210 1!)4/23/86 16: !!10 i!l4/23/86 18: QIQl Y.l4/2:;/86 2111: I21QI i?14/23/86 22: !2Hll BYTE RAW DATA ========== 295 58 59 297 56 57 299 55 57 3!211 54 56 31213 54 55 31215 54 56 307 54 56 31219 56 58 311 57 6121 313 59 59 315 57 59 317 56 59 DAILY AVERAGE VALUES 319 321 323 325 327 329 56 58 55 57 54 54 53 53 52 53 51 53 331 52 54 333 54 56 335 55 58 337 57 59 339 57 59 341 56 58 DAILY AVERAGE VALUES 343 56 57 345 54 55 347 52 53 349 51 51 351 50 5!21 353 50 52 355 53 56 357 57 61 359 58 61f.l 361 58 61 363 59 62 365 6!21 64 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 0.8 Ill. 6 1!1. 5 1!1. 4 10.4 0.4 0.4 0.6 0.7 0.8 0.7 fZI. 6 121.6 0.6 0.5 Y.l. 4 0.3 Ill. 2 0.1 0.2 0.4 es. 5 0.7 1!1. 7: 0.6 11:1.4 0.6 1!1. 4 !21. 2 121. 1 0.0 LiS. Ill 0.3 0.7 0.9 {!1. 8 0.9 1.0 0.5 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====== Ill. 9 121. 7 0.7 1!1. 6 121. 5 121. 6 121.6 0.8 1.0 0.9 V.I. 9 !21. 9 fZI. 8 !21. 8 0.7 !2i. 4 0.3 0.3 0.3 0.4 0.6 0.8 1!1. 9 0.9 0.8 es. 6 0.7 fll. 5 121. 3 fll. 1 0.0 0.2 121. 6 1. 1 1. Ql 1.1 1.2 1.4 0.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== 1214/24/86 l!li21: 121121 ~!14/24/86 1212: !!H!I 1214/24/86 ~tl4: IZH!i i2i4/24/86 !216: 1!10 1~14/24/86 08: 0121 1214/24/86 10: !2Ho 04/24/86 12:00 04/24/86 14:00 J-~14/24/86 16:00 i!l4/24/86 18: 0121 1214/24/86 2!21: 00 1!>4/24/86 22:1210 1!14/25/86 121!!1: 1210 04/25/86 1212:00 1!14/25/86 04: 01ZI 04/25/86 1216:00 !!14/25/86 !218: 121121 04/25/86 10:1210 to4/25/86 12:1210 1214/25/86 14:00 04/25/86 16:1210 1-!.14/25/86 18: 1!10 !!14/25/86 2121: Qlfll 1214/25/86 22:1210 !!14/26/86 1!10: 1210 04/26/86 02: IZH!I 04/26/86 I(J4: 0121 Ql4/26/86 {216: Ql0 1214/26/86 08:00 !!14/26/86 1121: !!1121 1214/26/86 12:00 1!14/26/86 14:1210 1214/26/86 16:1210 i214/26/86 18: 12H!I Y.i4/26/86 2121: 0121 lll4/26/86 22: 1!11!1 BYTE RAW DATA -------------------- 367 60 63 369 60 62 371 61 62 373 57 57 375 55 56 377 55 57 379 58 60 381 6121 64 383 63 67 385 63 67 387 64 68 389 64 67 DAILY AVERAGE VALUES 391 63 65 393 61 64 395 69 73 397 61 60 399 58 57 401 57 57 41213 58 59 405 59 62 407 62 66 409 63 67 411 64 67 413 63 66 DAILY AVERAGE VALUES 415 62 63 417 59 6121 419 63 67 421 62 62 423 57 56 425 56 57 427 57 59 429 58 61'21 431 59 61 433 59 62 435 61ll 63 437 6!!1 63 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 1.0 1. Ill 1.1 0.7 0.5 0.5 0.8 1.0 1. 3 1. 3 1. 4 1.4 1.0 1. 3 1. 1 1. 9 1. 1 0.8 0.7 0.8 0.9 1. 2 1. 3 1.4 1. 3 1.2 1.2 0.9 1. 3 1.2 0.7 0.6 0.7 Q!. 8 0.9 Ql. 9 1.1!1 1. 0 0.9 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====== 1. 3 1.2 1. 2 0.7 0.6 0.7 1. 0 1.4 1. 7 1.7 1. 8 1.7 1. 2 1.5 1.4 2.3 1 • l!J 0.7 121.7 0.9 1.2 1.6 1.7 1.7 1.6 1.4 1. 0 1.7 1.2 f2j. 6 (!l. 7 0.9 1. {21 1. 1 1.2 1. 3 1. 3 1. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 1.!14/27 /86 !21121: 1!10 Ql4/27 /86 1212: 0!21 Y.l4/27/86 04! t.:H!I 1!14/27 /86 1216: i!li!l 04/27/86 08: Qlf(.l IZ14/27 /86 10: Y.li!i 04/27/86 12:00 1214/27/86 14:-'110 fy4/27/86 16:00 1!14/27/86 18: QIIZI (!14/27/86 20:00 i!l4/27/86 22: Y.ll!l 1!14/28 I 86 ilif!l: eli!! !214128/86 !!12: !Zl0 l!S4/28186 04: IZl!Zl 1214/28186 06:00 04/28186 08:0121 Y.l4128186 10:00 1!14/28/86 12: l!lQI 1214 I 28/86 1 4: 121!21 04128/86 16: 0!21 04128/86 18:00 !214 I 28 I 86 2J21: f!H!I Y.l4/28/86 22: Ql0 V.l4 I 29 I 86 0!21: 121!21 1!14 /29 I 86 !Zl2: f21121 04129186 04:00 Y.14 I 29/86 !216: 121!21 04/29/86 08: Ql0 1214 I 29 I 86 10 : 121121 ~:14 /29186 12: IZI0 1!14/29186 14: 01ZI !214/29186 16:f!l0 io4t29 /86 18: l2lf2l (!14/29/86 20: 0!21 i!l4/29186 22: Y.HZI BYTE RAW DATA ==== -------------------- 439 6(1 62 441 59 6Y.I 443 58 60 445 60 61 447 56 56 449 56 57 451 58 61 453 60 65 455 63 67 457 66 71 459 68 74 461 69 73 DAILY AVERAGE VALUES 463 67 69 465 64 65 467 61 62 469 59 60 471 58 58 473 58 59 475 59 63 477 62 67 479 66 72 481 69 74 483 69 72 485 67 68 DAILY AVERAGE VALUES 487 64 64 489 60 61 491 59 58 493 57 57 495 56 57 497 57 59 499 59 63 51211 64 69 51213 68 75 51215 71 77 51217 7!tl 73 5!ZI9 67 68 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 1.0 0.9 0.8 1 • !21 0.6 0.6 0.8 1.0 1. 3 1. 6 1. 8 1.9 1. 1 1. 7 1.4 1.1 !21. 9 0.8 0.8 0.9 1. 2 1.6 1. 9 1.~ 1.7 1.3 1.4 1.0 0.9 0.7 0.6 121. 7 0.9 1.4 1.8 2.1 2.0 1.7 1.3 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: Ql5/29/86 12:00 CHAN 2 DEG C. ====== 1.2 1. 0 1.0 1.1 rll. 6 10.7 1. 1 1. 5 1. 7 2.1 2.4 2.3 1.4 1.9 1. 5 1.2 1. 0 0.8 QS. 9 1. 3 1.7 2.2 2.4 2.2 1.8 1.6 1.4 1.1 0.8 0.7 fc!J. 7 0.9 1. 3 1.9 2.5 2.7 1.8 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- Y.l4 I 3!!1 l 86 QH!i: QIQS Qi4/3!Zl/86 02: QIQI 04/:.::0/86 1?14: 00 !!14/31!1/86 !216: V.lt!l !214/3t71/86 !liB: 0!!1 i!l4 / 3!!1 I 86 1 {!I: I!H!I 12l4/3ll!/86 12: !210 !!14/3121/86 14: 0Jll !!.14/3QI/86 16: Ql0 !!14/31!!/86 18: !21121 1!14/3~!!/86 20: 01!1 IZl4 I 31?1/86 22: 1!11!1 !!15 / 1!11/86 0J21: 1!10 (!15/01/86 Ql2: 00 !!15 I 1!11 I 86 1!14 : Qlfll !215/ 1211 I 86 06 : !2!121 ~!15/01 /86 1218: 0J!l 1!15/01 /86 1121:00 1!15/ QJ 1 / 86 1 2 : IZll!l 05/!211/86 14: !lli.!1 {!15/!211/86 16: f21QI l!l5/!il1/86 18:00 Y.l5/lll1/86 21!1: IZI!c!l !!15/!211/86 22: Ql0 1!15/!212/86 Y.I!ZI: ~117.1 05/12!2 I 86 1212: !2Ji!l lll5/1212/86 04:0121 ~~15/!!12/86 1!16: IZIY.l Y.l5/IZI2/86 1218:00 ~?.15/ !!12/86 lY.l : !21!21 !215/!212/86 12: j~Qj l215/Ql2/86 14: Qil!l 1!15/1Zl2/86 16:1210 !215/02/86 18: !!IY.i QI5/S1.l2/86 2!21: 0lll Ql5/i?.l2/86 22: !Zilll BYTE RAW DATA ===== =========:::::: 511 64 64 513 61 61 515 59 59 517 57 57 519 57 57 521 58 60 523 61 65 525 65 71 527 70 76 529 72 77 531 72 75 533 69 71 DAILY AVERAGE VALUES 535 67 68 537 65 67 539 64 66 541 63 65 543 63 65 545 63 65 547 64 67 549 66 70 551 68 73 553 712f 74 555 70. 74 557 68 69 DAILY AVERAGE VALUES 559 64 65 561 61 61 563 59 59 565 58 58 567 57 57 569 58 59 571 61 64 573 65 71 575 69 75 577 71 75 579 7fZI 72 581 67 69 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 1.4 1.1 0.9 Ill. 7 0.7 Ill. 8 1.1 1. 5 2.0 2.2 2.2 1. 9 1.4 1.7 1.5 1.4 1.3 1.3 1.3 1.4 1. 6 1.8 2.0 2. "~ 1. 8 1.6 1. 4 1. 1 0.9 Ill. 8 0.7 0.8 1.1 1.5 1.9 2.1 2. t!l 1.7 1. 3 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ------------ 1.4 1.1 0.9 0.7 Ill. 7 1. Ill 1.5 2.1 2.6 2.7 2.5 2. 1 1.6 1.8 1.7 1. 6 1. 5 1.5 1.5 1.7 2.0 2.3 2.4 2.4 1.9 1.9 1.5 1. 1 0.9 0.8 !2f. 7 !21.9 1.4 2.1 2.5 2.5 2.2 1.9 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-I!S2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== 1.!15/ Y.l3/ 86 t!SY.i: (!JQI !215/1!13/86 1212: IZll!l Ql5/03/86 12'14: 00 l!f5/fll3/86 !Zl6:!.!10 1215/03/86 08:00 1215/12'13/86 10:1!1!.!1 £:!15/03/86 12: t21!21 1!15/l!l3/86 14:1210 !215/03/86 16:00 t'f5/1!13/86 18: IZIQI l!$5/1!13/86 2SZI: (iSJ2l 1215/03/86 22: QIQI 1Zl5/ 04 I 86 QlQI: l~l!Zl !215/!214/86 1212:00 !215/!!14/86 1214:121121 !!15/ 1214/86 06: tG10 05/1214/86 1218: 1211ZI 1215/!!14/86 10:00 !.!15/!214/86 12: 121121 Y.l5/!ll4/86 14:00 !215 I !!14/86 16: Ql121 1215/1214/86 18:0121 ~215/1!14/86 2121: 0!21 05/f2l4/86 22:00 (!15/05/86 0121! 00 1215/!215/86 02:fl10 1215/05/86 04: 00 lo5/!ZI5/86 1216:00 1215/1215/86 IllS: 00 i!l5/05/86 l!ZI: Jll0 1215/11.15/86 12:0!21 !215 / 1!15 I 86 14: 121121 1215/05/86 16:0121 i!S5/1215/86 18: 1!1121 1215/!!15/86 21!1! 01.!1 1!15/1!15/86 22: 1211!1 BYTE RAW DATA ==== ========== 583 65 66 585 64 65 587 62 63 589 61 62 591 61 62 593 62 64 595 64 67 597 67 71 599 69 74 601 71 75 603 71 75 61!15 70 73 DAILY AVERAGE VALUES 61217 68 70 609 66 67 611 65 66 613 64 65 615 64 65 617 64 65 619 64 66 621 65 67 623 67 70 625 68 72 627 69 72 629 68 71 DAILY AVERAGE VALUES 631 66 67 633 63 63 635 61 60 637 59 58 639 58 58 641 58 59 643 61 65 645 67 73 647 74 82 649 78 85 651 78 83 653 74 75 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 1. 5 1.4 1.2 1.1 1. 1 1.2 1. 4 1.7 1. 9 2.1 2.1 2.0 1.6 1.8 1. 6 1.5 1.4 1.4 1.4 1.4 1. 5 1.7 1. 8 1.9 1. 8 1.6 1.6 1. 3 1. 1 0.9 0.8 0.8 1. 1 1.7 2.4 2.8 2.8 2.4 1.6 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====== 1.6 1.5 1. 3 1.2 1.2 1.4 1.7 2.1 2.4 2.5 2.5 2.3 1.8 2. ~J 1.7 1.6 1.5 1.5 1. 5 1.6 1.7 2.0 2.2 2.2 2. 1 1.8 1.7 1. 3 1.0 0.8 Ill. 8 0.9 1.5 2.3 3.2 3.5 3.3 2.5 1. 9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page Hl 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 1!151!:!16/86 !llt!l: !210 05/lo6/86 £12: IZHZI ~<!l5/!Zi6/86 Q~4: Ql!Zl !?15 I !!16 I 86 1216 : 01.!1 0511216/86 1218:00 051el6/86 1e1: 00 1215/1.':16/86 12:0f!S 1!15/1216186 14: 0!ll m51f2')6/86 16: 0!21 0511116/86 18: 0fZI IZ15/i!.16/86 20: !21€1 f?J5106186 22: 01.!1 05 I Q'l7 I 86 121121: 0121 I215/!Zf7 /86 02:1210 05/1217/86 1114: 1!10 05/1217/86 1216: 00 f!l5/12l7 /86 1!18: k11ZI 051!217/86 10:00 k151!Zl7 186 12: 0!21 f215/07 /86 14: 12!0 1!15/07 /86 16: 9.1fll k:l5/07 /86 18:0121 1215/07/86 2121: 00 Y-15/07/86 22: f210 Y.IS/1!18/86 1210:s1.10 1!15/1!18/86 02: f210 !215/1?.18/86 ~·4: 00 1!15/ fZI8 I 86 06: !ZIIZI 1215/(!18/86 08: QIJ!I 1!15/1218/86 U!i: 121121 1215/!1.18186 12: ~1121 i215/IZI8/86 14:1210 Y.l5/!2l8/86 16: 00 f215/li.l8/86 18: 01!1 k:15/f!l8/86 20: S!l0 f!l5 I 1!18/86 22: IlliZI BYTE RAW DATA ========== 655 69 7121 657 66 66 659 63 63 661 61 61 663 61 61 665 62 64 667 65 69 669 70 75 671 74 80 673 75 81 675 74 77 677 71 72 DAILY AVERAGE VALUES 679 68 68 681 65 65 683 62 61 685 60 60 687 60 60 689 61 63 691 63 67 693 68 74 695 73 79 697 75 80 699 74 77 71ZH 72 74 DAILY AVERAGE VALUES 703 69 7!ll 71215 67 67 707 65 66 709 64 65 711 64 66 713 65 67 715 67 70 717 69 73 719 71 74 721 71 75 723 70 73 725 68 69 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 1.9 1.6 1. 3 1.1 1 .. 1 1.2 1 .. 5 2 .Ill 2.4 2.5 2.4 2.1 L8 1.8 1.5 1. 2 1.0 1 • 121 1 .. 1 1. 3 1.8 2.3 2.5 2.4. 2.2 1. 7 1. 9 1. 7 1. 5 1. 4 1.4 1.5 1. 7 1.9 2.1 2.1 2. 121 1.8 1.7 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05129/86 12:00 CHAN 2 DEG C. ====== 2. Ill 1. 6 1.;:) 1.1 1.1 1.4 1.9 2.5 3.0 3.1 2.7 2.2 2.0 1. 8 1. 5 1.1 1. 0 1. as 1. 3 1.7 2.4 2.9 3.0 2.7 2.4 1.9 2.0 1.7 1.6 1.5 1.6 1. 7 2. Ill 2.4 2.5 1.9 2.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 1215109186 !21121: 0!21 $!15109186 1212:121!.!1 1215/1219/86 Ql4: 0121 i!l5/l219 186 !!16: 0121 0511219186 !Z18: 00 1!151!219186 1121: 0fil 1215109186 12:00 t!I51SZ19186 14:01{1 05109186 16:00 051!!19186 18: 121!21 fll51f.!l9 186 21Zl: 0f21 IZ151l219186 22: 1!10 l215 I 1121 I 86 0f21 : 1.!10 Y.l51 10 I 86 1!12: 0!21 Y.l511flll86 04:0121 1!15 I 1 121 I 86 1216: 121121 1!15/ 10 I 86 !218: f21f21 l2151 10/86 10:00 1!151 Hll86 12: 0!21 Ql5/ 14!1186 14: 121121 tZl51 lY.i 186 16: 121!.!1 051 11!1186 18: 01:!1 1!15 I 1 Ql I 86 2121: fllf21 IZI5/l.V.l/86 22:0121 05111186 00: !21121 1215111/86 02: 121121 !215/11186 1214:121121 1215111186 06;1210 1215 I 11 /86 1!18: Lil0 1!151 11 186 lQI: 0!21 05/11.186 12: 121!21 ri.l5111186 14:0121 1!15/11 186 16: 12H!I 051 11/86 18: 1!1!21 1215/11186 2121:0Ql 1!151 11 186 22: 0121 BYTE RAW DATA ==== ========== 727 65 65 729 63 64 731 62 62 733 61 62 735 61 62 737 62 64 739 65 68 741 67 71 743 69 73 745 69 72 747 68 70 749 67 69 DAILY AVERAGE VALUES 751 66 67 753 65 66 755 64 65 757 63 64 759 63 64 761 63 65 763 64 66 765 65 67 767 66 68 769 66 68 771 66 68 773 65 67 DAILY AVERAGE VALUES 775 64 64 777 60 60 779 58 57 781 56 55 783 56 57 785 58 6~1 787 61 64 789 64 68 791 68 74 793 71 77 795 72 76 797 71 73 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 1 1:::' .;u 1. 3 1. 2 1.1 1.1 1. 2 1. 5 1.7 1. 9 1.9 1.8 1.7 1. 5 1. 6 1.5 1.4 1.3 1. 3 1.3 1.4 1.5 1.6 1. 6 1. q 1. 5 1. 5 1. 4 1. 121 0.8 0.6 0.6 0.8 1.1 1.4 1.8 2. 1 2.2 2. 1 1. 3 DATA FILE : RIFFLE02 START: 04108186 18:00 STOP: 05129/86 12:00 CHAN 2 DEG C. ====== 1. 5 1.4 1. 2 1.2 1.2 1.4 1.8 2.1 2.3 2.2 2. 1!1 1.9 1.7 1.7 1 .. 6 1.5 1. 4 1. 4 1.5 1.6 1.7 1.8 1.8 1.8 1. 7 1.6 1. 4 1.1!1 0.7 U1. 5 0.7 1.0 1.4 1.8 2.4 2.7 2.6 2.3 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-~1.1 DEG C TEMP/TEMP RECORDER Page 12 12-12~2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== Ql5/ 12/86 1210: 0!21 !!15/12/86 Ql2: !ZI0 1215/12/86 !!14: 00 1!15/12/86 l!l6:r2lf2l 05/12/86 JZJB: 0r21 ~151 12186 1121:09.1 !215/12186 12:0!!1 !!15112186 14:121121 1215/12186 16:00 1215112186 18: 1!19.1 1215/12186 2121:1210 ,!15/ 12186 22: 121!21 05/ 13/86 121121: 0121 I!J5/ 13/86 1212: 121121 1!15/ 13 I 86 !Zi4: 1!1121 1!15/13186 06:1210 1!15/ 13186 1218: 0121 1215113186 10:121lll 1!151 13/86 12: IlliZI 1215/13186 14: 0fll 1!15/ 13/86 16: !lSI!l QJ!:il13186 18:0!..il !!15/ 13186 2lll: 0121 {215/13186 22:0121 1!151 14/86 0121:00 S!l5/ 14/86 !212: J!ll2i Ql5/ 14/86 1214: 1210 i?l5 I 14 I 86 1216: IlliZI 1215/14/86. 08:00 !!15/ 14/86 HI: !!H!! 1215/14/86 12: f2IJ!l 1!15/14 / 86 1 4: 1210 1215/14/86 16:!21f(.l i!l5/14/86 18: 121!21 1!15 / 14 I 86 2!.iJ: !!S!li !?.15114/86 22:1!10 BYTE RAW DATA -------------------- 799 69 71 BllH 66 67 81213 64 65 805 62 63 807 62 63 809 63 65 811 66 70 813 73 80 815 78 87 817 82 89 819 82 87 821 78 81 DAILY AVERAGE VALUES 823 74 75 825 70 69 827 66 66 829 64 64 831 64 64 833 64 66 835 67 7lll 837 71 76 839 74 77 841 74 77 843 73 75 845 71 73 DAILY AVERAGE VALUES 847 69 71 849 67 68 851 66 66 853 65 66 855 65 67 857 67 69 859 69 73 861 72 77 863 74 78 865 74 77 867 72 74 869 71!1 71 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 1.9 1.6 1.4 1.2 1. 2 1. 3 1.6 2.3 2.8 3.2 3.2 2.8 2.0 2.4 2.0 1.6 1. 4 1.4 1.4 1. 7 2.1 2.4 2.4 "'") "':!' L• "'""! 2.1 1.9 1.9 1. 7 1. 6 1.5 1.5 1.7 1. 9 2.2 2.4 2.4 2.2 2 • .Zl 1.9 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ------------ 2.1 1.7 1.5 1. 3 1. 3 1. 5 2.0 3. 121 3.7 3.9 3.7 3.1 2.4 2.5 1. 9 1.6 1.4 1.4 1.6 2.12' 2.6 2.7 2.7 2.5 2.3 2.1 2.1 1.8 1. 6 1. 6 1.7 1.9 2.3 2.7 2.8 2.7 2.4 2. 1 2.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 13 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T Il'lE ======== ---------- Y.l5/15/86 IZHZl:!2ll21 !!15/15/86 !212: lll0 1215/15/86 04: 0!21 1215/15/86 06: Y.lf2l 1215/15/86 08:00 1!15 / 15/86 1121: 121J!I f!l5/15/86 12:00 05/15/86 14:00 05/15/86 16:00 05/15/86 18: 121!!1 1215/15/86 20:0121 1215/15/86 22: 00 05/16/86 flH!I:Y.l0 !215/ 16/86 02:00 ~!15/16/86 !ZI4:t!ll!l 1!.15/16/86 1216:0121 1!15/ 16/86 IllS: t!H!l 05/16/86 1!21: 1210 '!15/16/86 12:121121 ~15/ 16/86 14:00 J!f5/1 6/ 86 16: t!lY.I 1215 I 1 6/86 1 8: 1!10 05/16/86 20:1Zl!ZI Y.15/ 16/86 22:0121 £15/17/86 1!10: !210 05/1 7/86 1212: 121!21 1!15/ 17/86 !214: 1210 !!15/ 17/86 1216: 00 1215/17/86 08:0121 V.15/ 17/86 1!!1: 1210 05/17/86 12:0121 Ql5/17/86 14:0!9 lt:S5/17/86 16:00 !!15/ 1 7 I 86 1 8: 1210 05/17/86 2121:1210 Y.l5/17 /86 22: 121121 BYTE RAW DATA ========== 871 67 68 873 66 66 875 64 65 877 63 64 879 63 65 881 65 67 883 67 71 885 72 77 887 75 81 889 76 81 891 75 78 893 72 73 DAILY AVERAGE VALUES 895 69 69 897 66 66 899 65 65 91211 64 64 903 63 64 905 64 66 907 67 71 91219 71 75 911 74 78 913 75 78 915 74 76 917 72 74 DAILY AVERAGE VALUES 919 70 72 921 68 69 923 67 67 925 65 66 927 65 66 929 66 68 931 69 73 933 74 81 935 79 86 937 81 87 939 81 84 941 77 79 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 1. 7 1. 6 1.4 1. 3 1.3 1. 5 1. 7 2.2 2.5 2.6 2.5 2.2 1.9 1.9 1.6 1.5 1.4 1. 3 1.4 1.7 2.1 2.4 2.5 2.4 2.2 1.9 2.0 1.8 1. 7 1. 5 1.5 1.6 1. 9 2.4 2.9 3.1 3.1 2.7 2.2 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ------------ 1.8 1.6 1.5 1.4 1. 5 1.7 2.1 2.7 3. 1 3.1 2.8 2.3 2.1 1. 9 1. 6 1.5 1. 4 1.4 1. 6 2.1 2.5 2.8 2.8 2.6 2.4 2.1 2.2 1.9 1.7 1.6 1.6 1.8 2.3 3.1 3.6 3.7 3.4 2.9 2.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 14 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- 05/18/86 0121:0121 i!l5 / 18/86 IZI2: Y.l!21 1215/18/86 04:0!21 !1.15/18/86 1216:1lS!21 05/18/86 08:~S0 1!15/18/86 1!21:Y.It21 1215/18/86 12:00 1!15/ 18/86 14: 12112! f2l5/ 18/86 16:0121 ~!15/ 18/86 18: 0121 05/18/86 212l:f2h21 Y.l5/ 18 I 86 22: 1!1121 1215/ 1 9 I 86 121111: 0121 1215/19/86 02:00 1215/ 19/86 1214: 00 t:15/19/86 !216:0!21 1!15 I 1 9 I 86 !liS: 1210 1215/19/86 10:0121 1!15/19/86 12:!211Zl 05/19186 14:00 1215 I 1 9 I 86 1 6: k1Y.I !215/ 19/86 18:00 i!l5/1 9/86 2!21: !210 05119/86 22: llHZl 1215120/86 00:1210 1!!5/2!21/86 12!2: 01!1 05120/86 1214:00 Ql5/2fll/86 fll6: 0!21 es5/2J2l/86 08: sz10 V.i5/2!ZI/86 1121: lllf!l !:!15/2!i!/86 12:0121 1215/2J!.I I 86 14: 1211!1 1?.15/21!5/86 16: lll!il !!15/2!21186 18: 1211!1 !!15 I 2!!1 I 86 2121: 1211.!1 1!15/2!?.1/86 22: f!IQI BYTE RAW DATA ==== --------------------943 74 75 945 71 71 947 69 69 949 67 67 951 67 68 953 67 69 955 70 75 957 76 83 959 82 88 961 83 88 963 80 83 965 76 78 DAILY AVERAGE VALUES 967 74 74 969 71 71 971 68 67 973 65 65 975 64 64 977 65 66 979 68 73 981 76 83 983 82 90 985 85 91 987 83 86 989 79 79 DAILY AVERAGE VALUES 991 74 74 993 70 69 995 67 66 997 65 65 999 64 65 l!ZI01 66 68 1003 7121 74 10135 75 82 10!{.17 81 87 1!!11219 83 87 11~111 8l 84 1Y.I13 77 77 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 2.4 2.1 1. 9 1. 7 1. 7 1.7 2.0 2.6 3.2 3.3 3.0 2.6 2.4 2.4 2.1 1.8 1. 5 1.4 1. 5 1. 8 2.6 3.2 3.3 2.9 2.3 2.4 2.0 1.7 1. 5 1. 4 1.6 2.0 2.5 3.1 "':"' ..,.. ,._, . .._) 3 .. 1 2.7 DATA FILE : RIFFLE02 START: 04108/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ------------ 2. 1 1.9 1.7 1.8 1.9 2.5 3.3 3.8 3.8 3.3 2.8 2.6 2.4 2.1 1.7 1. 5 1. 4 1 1.6 2.3 3.3 4.0 4.1 3.6 2.9 2.6 2.4 1.9 1.6 1.5 1. 5 1. 8 2.4 3.2 3.7 3.7 3.4 2.7 2.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 1215/21/86 00: 0~~~ ~!15/21 /86 02: IZI!ZI 1.!15/21/86 !214: 0V.I 1!15/21/86 f2i6: 00 1215/21/86 ~?.S8:012l 05/21/86 11!1: IZHZI !215 I 2 1 I 86 12: fZIIZi {!15/ 21 I 86 14: 121121 05/21/86 16: 121!!1 05/21/86 18: ~2Sl21 05/21/86 20: 0121 IZI5/21 /86 22: !Zh21 1215/22/86 0121:1210 1215/22/86 ~!12: 1!10 !!15/22/86 1214: lllfZl 1!15/22/86 06: 0121 1215/22/86 08:1211!1 05/22/86 Hi: fZl0 1215/22/86 12:0121 1!15 I 22/86 14 : l!l!ZI lil5/22/86 16: 01!1 05/22/86 18: 01!1 1215/22/86 21!1: 1!11!1 !!15/22/86 22: QIY.I 1215/23/86 Clli!.l: 00 1215/23/86 1212: 0121 1215/23/86 1214: 1!10 1!15/23/86 1216: !21!21 05/23/86 1218: 121121 !215/23/86 H!l: fZl!Zl 05/23/86 12: illfZI 1?15/23/86 14: 01!1 1215/23/86 16: 1210 1215/23/86 18: 1211!1 !:~15/23/86 21ll: 1210 Y-15/23/86 22: IZliZI BYTE ==== Hl15 1!2117 1019 112121 RAW DATA ========== 73 7 ? ..... 69 68 66 65 64 64 112123 63 63 112125 65 66 1027 68 73 1029 76 83 1031 82 89 112133 83 89 1035 81 83 1037 76 77 DAILY AVERAGE 1039 72 71 1041 68 68 1043 67 67 112145 67 67 1047 66 67 1049 67 69 1051 71tl 75 1053 76 83 11!155 80 87 1057 81 87 1f2159 80 83 11!161 76 77 DAILY AVERAGE 11:!163 74 74 1065 72 72 1067 70 70 1 !2169 69 69 1071 68 69 11!173 69 71 1075 72 77 1QI77 77 84 112179 81 89 112181 83 88 Hl83 81 84 11!185 77 79 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== 2.3 1.9 1.6 1.4 1.3 1.5 1. 8 2.6 3.2 3.3 3.1 2.6 2.2 2.2 1. 8 1.7 1. 7 1.6 1. 7 2.0 2.6 3.121 3.1 3. !2) 2.6 2.3 2.4 2.2 2. Ql 1.9 1.8 1.9 2.2 2.7 3.1 3.3 3.1 2.7 2 .. 4 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====== 2.2 1.8 1. 5 1.4 1. 3 1.6 2.3 3.3 3.9 3.9 3.3 2.7 2.4 2.1 1. 8 1.7 1.7 1.7 1.9 2.5 3.3 3.7 3.7 3.3 2.7 2.5 2.4 2.2 2.0 1.9 1. 9 2.1 2.7 3.4 3.9 3.8 3.4 2.9 2.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== !215/24/86 0121:1210 1215/24/86 02:00 1215 I 2 4 / 86 !!14 : 0121 !215/24/86 !216: !!1!21 05/24/86 08: 1!1121 !115/ 24 I 86 1121: f.!l!!l 1!15/24/86 12:00 !215/24/86 14: s{lfZI 05/24/86 16:00 i!l5/24/86 18: 01!1 Q15/24/86 20:00 !?15/24/86 22: 1!10 1215/25/86 121!21: 121!!1 05/25/86 1!12: ~19.1 1!15/25/86 1214: !!1!21 !215/25/86 06: 01!1 !215/25/86 !218: Qlfll 1!.15/25/86 1121: 00 i!l~;/25/86 12:1!h!l 1215/25/86 14~121!21 1!15/25/86 16: 1!10 1215/25/86 18:0121 !!15/25/86 2121: IlliZI Ql5/25/86 22: QIQI fZI5/26/86 !!1121! 0QI 1!15/26/86 !212: 0121 1215/26/86 04: 0121 1!15/26/86 06: 121!21 !!15/26/86 !218: f21Ql !!15/26/86 HI: 121!21 !-!15/26/86 12:00 iZl5/26/86 14: 1211!1 !215/26/86 16: !211:!1 !!15/26/86 18: !!1!21 ~J5/26/86 2!2!: Ql0 !!15/26/86 22: V.l!Zl BYTE RAW DATA ========== HIS? 74 74 112189 71 71 112191 69 68 1!2193 68 68 1095 67 68 112197 69 71 1099 72 78 1 Hl1 78 86 1103 84 91 1105 84 9121 1 H!7 82 85 1109 78 79 DAILY AVERAGE VALUES 1 1 1 1 1113 1115 1117 1119 1121 75 75 73 73 71 72 71 71 71 73 73 76 1123 76 82 1125 8121 88 1127 83 9Qi 1129 83 87 1131 81 83 1133 78 79 DAILY AVERAGE VALUES 1135 75 76 1137 74 75 1139 73 73 1141 71 73 1143 72 73 1145 73 75 1147 75 79 1149 77 83 1151 80 86 1153 82 87 1155 81 85 1157 79 80 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 2.4 2.1 1.9 1.8 1.7 1.9 2.2 2.8 3.4 3.4 3.2 2.8 2.5 2.5 2 .. 3 2.1 2.1 2.1 2.3 2.6 3.0 3.3 2.8 2.6 2.5 2.4 2.3 2. 1 2.2 2.3 2.5 2.7 3. 1!1 3.2 3.1 2.9 2.6 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====== 2.4 2. 1 1.8 1.8 1.8 2.1 2.8 3.6 4.1 4. (!I 3.5 2.9 2.7 2.5 2.3 2.2 2.1 2.3 2.6 3.2 3.8 4.0 3.7 3.3 2.9 2.9 2.6 2.5 2.3 2.3 2.3 2.5 2.9 3.3 3.6 3.7 2.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ---.. -----· --------===== ll15/27/86 Ql0: f210 1215/27/86 Y.l2:k11Zl !Z!5/27 /86 1214:00 1!!5/27 /86 1!16: 0!21 !?.15/27 /86 ~!18: !{10 S215/27/86 10; t!lf21 05/27/86 12: 1!10 1215/27/86 14;00 05/27/86 16:00 1!15/27 /86 18: 0t?l 05/27/86 2121: !210 £15/27/86 22: IZl!!l 05/28/86 121121: 121121 $?.15/26/86 !!12: !Zif2J 1~15/28/86 04: 0!Zl Q'l5/28/86 !!16: 00 !05i28/86 1218: !!1121 05/28/86 10: !ZH?I 12!5/28/86 12:00 JZI5/28/86 14: 01!1 1!15/28/86 16: 1!1!21 !!15/28/86 18:00 !215/28/86 20: 1!10 Ql5/28/86 22: 0Ql 1215/29/86 !!h~l: 00 1!15/29/86 I212:Qifll 1!15/29/86 1214: 0!21 !!15/29/86 06: ~!SQI 1215/29/86 08: 0!21 !215/29/86 HI: Y.IIZI BYTE RAW DATA ========== 1159 76 76 1161 74 74 1163 72 72 1165 71 71 1167 71 72 1169 72 75 1171 75 81 1173 79 86 1175 81 86 1177 8121 84 1179 80 82 1181 78 8!21 DAILY AVERAGE VALUES 1183 1185 1187 1189 1191 1193 1195 1197 1199 121211 77 78 75 76 74 75 73 74 73 75 74 77 78 84 9:::.; 912'1 86 93 87 93 121213 86 88 12Y.I5 82 83 DAILY AVERAGE VALUES 121!17 79 79 1209 76 76 1211 74 75 1213 73 74 1215 73 74 1217 74 76 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 2.6 2.4 2.2 2.1 2.1 2.2 2.5 2.9 3.1 3. 121 3 .. 0 2.8 2.6 2.7 2.5 2.4 2.3 2.3 2.4 2.8 3.3 3.6 3.7 3.6 3.2 2.9 2.9 2.6 2.4 2.3 '"') ...,.. "'-• ·-' 2.4 2.5 DATA FILE : RIFFLE02 START: 04/08/86 18:00 STOP: 05/29/86 12:00 CHAN 2 DEG C. ====== 2.6 2.4 'i '"') .......... 2. 1 2.2 2.5 3.1 3.6 3.6 3.4 3. V.i 2.8 2.8 2.6 2.5 2.4 2.5 2.7 3.4 4.3 4.3 3.8 3 .. 3 3.2 2.9 2.6 2.5 2.4 2.4 2.6 2.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-IZI2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH BEGIN OBS : DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 END OBS :LOW BATTERIES -NEW CHIP FAILED -CHAN1=8.0~CHAN2=8.3 DATE TIME ======== ===== !!15/29/86 14: 1?.1~) 05/29/86 16:121121 i!l5/ 29/86 18: 121~1 !!15/29 /86 21!1: 00 1!15/29/86 22:0f!l (?.15/:;.;QI/86 00:00 iZIS/31!1/86 1!12: !!If!! i!15/31!1/86 1214:0121 S2l5 I 31!1 /86 1216 : 00 1!15/ 31!> /86 !218: 1210 !!15/31!.1/86 HI: f!lt!l lo5/31!i/B6 12: 0e1 Ql5/3!2i/86 14:121121 1!15/30/86 16:00 l!l5/3i!l/86 18: 12H!I 1215/3121/86 20: 01!1 05/3!21/86 22: 0{21 i!15/31 /86 1210: IlliZI l!15F51/86 !!12: 1210 1!15 I 31 I 86 1214: 121121 1!>5131186 1216:00 i!IS/31186 1218:121121 05/31/86 10:0121 1215131/86 12:0121 1215131186 14:00 !!15/31 186 16:0121 1!15131 /86 18: 1211!1 ill5/3 1 I 86 2!21: 1211!1 !llS/31/86 22:00 1216 I 01 I 86 !!1(!1: 0!.!1 ~!161!!11 186 !!12: fZII21 Y.i6/!i.ll 186 !214: 1210 i!16 I fi 1 I 86 1!16 : Y.l!!l !(.16 I 1?.!1 / 86 !~i8 : 121lll i!l6 / i!ll I 86 1121: Ql121 !Zl6/1!11/86 12:01!1 !!16 / !211 I 86 14: 1.!1121 ~161llli/86 16:1211!1 i216 I !Zl1 I 86 1 8 : I!H!I !Zi6h2ll /86 20: 1!10 i!l6/V.i1 186 22: !!1!21 BYTE RAW DATA ==-======== 1 78 84 3 84 92 5 88 96 7 89 95 9 87 90 DAILY AVERAGE VALUES 11 84 85 13 81 82 15 79 8.0 17 78 79 19 77 78 21 76 78 23 77 81!1 25 78 82 27 8i!l 84 29 82 86 31 83 86 33 82 84 DAILY AVERAGE VALUES 35 80 82 37 78 79 39 77 78 41 77 78 43 76 78 45 75 77 47 76 78 49 77 80 51 79 83 53 81 85 55 82 86 57 82 86 DAILY AVERAGE VALUES 59 82 84 61 80 82 63 79 Bt!i 65 77 78 67 76 77 69 76 77 71 77 79 73 78 82 75 81 85 77 82 86 79 82 85 81 81 83 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 2.8 3.4 3.8 3.9 3.7 3.5 3.4 3.1 2.9 2.8 2.7 2.6 2.7 2.8 3.121 3.2 3.3 3.2 3.0 3.§2! 2.8 2.7 2.7 2.6 2.5 2.6 2.7 2.9 3.1 3.2 3.2 2.8 3.2 3. f!S 2.9 2.7 2.6 2.6 2.7 2.8 3.1 3.2 3.2 3. 1 2.9 CHAN 2 DEG C. ====== 3.4 4.2 4.6 4.5 4. Y.l 4. 1 3.5 3.2 3. 121 2.9 2.8 2.8 3. 1.(1 3.2 3.4 3.6 3.6 3.4 3.2 2.9 2.8 2.8 2.8 2.7 2.8 3.0 3.3 3.5 3.6 3.6 3. 1 3.4 3.2 3. 121 2.8 2.7 2.7 2.9 3.2 3.5 3.6 3.5 3.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== 1!16/~12/86 1210: QJQi !216/1!12/86 !212: 1!1121 1216/\112/86 !214: 1!1121 ~216/1!12/86 fl$6: 1!11!1 !l161J.!I2/86 !~18: J!H~I 1!16/1!12/86 11!1: IM"I f2l6/J2l2/86 12: !2H!I !216/1212/86 14:121121 £16/1212/86 16: 00 ~!16/1!12/86 18:121521 1216/02/86 21!1: 0121 !216/1212/86 22: f.!IIZI 1216 I 1!13/86 f.!H!I: &21121 1!16/1213/86 02! 00 I216/Y.l3/86 1.(14: !211!1 jll6/03/86 06: 0Y.l !!16/1213/86 fZI8! QlfZI 1216/!213/86 10:00 i216/t213/86 12: l!l!il 1216/03/86 14: 1!1!21 1!16/1213/86 16: 1!10 1216/1213/86 18:00 Ql6/l!l3/86 20:121121 06NJ3/86 22:121121 !!16 / 1!14/86 121!21: 0121 1216/!ZI4/86 121.2: l!lfZI 1216/1!14/86 1214:1210 1216 I 1214 I 86 IZ16: 1211!1 1216 I 1214 I 86 1218: 00 1!16/1!14/86 1 !21: 121121 06/1!.14/86 12: !211!1 f?.l6/l214/86 14: ~!1121 QI6/J214/86 16: 1!10 !96 I 1214/86 1 8 : 1!11!1 !Z16/J~I4/86 2!!1: ~!il21 !!16 I 1!14/86 22: 1!11!1 BYTE RAW DATA ==== ========== 83 81!1 82 85 79 8121 87 77 79 89 76 77 91 75 76 93 75 77 95 75 78 97 77 8121 99 79 83 UZI1 80 84 103 81 84 105 81ZI 83 DAILY AVERAGE VALUES 11217 79 82 109 78 8121 111 78 79 113 77 79 115 77 79 117 77 79 119 77 8!21 121 79 8.2 123 80 83 125 81 84 127 81 85 129 82 85 DAILY AVERAGE VALUES 131 82 84 133 81 83 135 8121 82 137 79 81 139 79 80 141 79 81 143 79 81 145 79 82 147 81 84 149 81 85 151 82 85 153 82 84 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 3. J!l 2.9 2.7 2.6 2.5 2.5 2.5 2.7 2.9 3. 121 3.1 3.1!1 2.8 2.9 2.8 2.8 2.7 2.7 2.7 2.7 2.9 3. 1!1 3 .. 1 3. 1_ 3.2 2.9 3.2 3.1 3. 121 2.9 2.9 2.9 2.9 2.9 3.1 3.1 3.2 ":" .., ._-.. L DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ====== 2.9 2.7 2.6 2.7 2.8 3.0 3.3 3.4 3.4 3.3 3.0 3. 1!1 2.9 2.9 2.9 2.9 3. J!i 3.2 3.3 3.4 3.5 3.5 3.1 3.4 3.3 3.2 3.1 3. 121 3. 1 3.1 3.2 3 .. 4 3.5 3.5 3.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-~1.1 DEG C TEMP/TEMP RECORDER Page 3 12-fl~2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME BYTE RAW DATA --------------------------========== QI6/Ql5/86 f(.lfll: 1!10 i.!I6/!ZI5/86 1!12: ~!10 i!l6/J!I5/86 04: 0i!l J!l6/1!15/86 £!16: 1211!1 06/1!15/86 08: I!IIZI 1~6/05/86 HI: l!ll!l 1!16/05/86 12: 1!10 1!16/1215/86 14: 1!11!1 Ql6/f215186 16:£10 Y.l6 I tiJ5 I 86 18: !21121 1!16 I 1!15 I 86 20: 1!11!1 !!16105/86 22: 121!21 Ql6/lil6186 €11!1: 0!!1 1!16/06/86 02: lil0 06 I 1!16 I 86 04 : 1!10 06106/86 1.!16: 1!1!21 ~!16106186 1!18: J!l0 1!16/!!.16186 10:00 ~!S611!16186 12: 1!10 1216/!216186 14: 01!1 1!1611!16186 16: 1!1£1 0611!16186 18: f210 !!1611!16186 20: QI!ZI 06/!?.16186 22: IZH!I 06107186 !210! 0Y.l 1!~6/07 /86 02: QIJ!I QI6/QI7 186 04: QIQI 1!1611!17 186 06:0121 !2161QI7 186 08! 00 ,!16/ Ql7 /86 1!21: 1210 Y.l6/07 186 12: i!IQI !?,1611217 186 14: 1!10 !2161!!17/86 16:00 !2161t!i7 /86 18: !Zll!l ~16 I 07 I 86 21!1: 1!1£1 06 I Q!7 I 86 22: !Zll!l 155 8121 82 157 79 81 159 79 81 161 79 8!!1 163 78 80 165 78 81 167 79 82 169 8!.!1 85 171 82 86 173 84 89 175 86 90 177 86 89 DAILY AVERAGE 179 84 85 181 81 82 183 79 8121 185 78 79 187 77 78 189 77 78 191 77 81!1 193 79 82 195 80 83 197 81 85 199 82 86 201 82 85 DAILY AVERAGE 2103 82 84 2!215 82 84 207 81 84 21!19 81 83 211 81 83 213 81 83 215 82 86 217 86 91 219 90 97 221 93 99 223 92 96 225 9~21 92 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ------------ 3. ~~ 2.9 2.9 2.9 2.8 2.8 2.9 3.£1 3.2 3.4 3.6 3.6 3.1 3.4 3.1 2.9 2.8 2.7 2.7 2.7 2.9 3. 121 3.1 3.2 3.2 3. 121 3.2 3.2 3.1 3.1 3.1 3.1 3.2 3.6 4.0 4.3 4.2 4. !21 DATA FILE : RIFFLE03 START: 05129186 14:00 STOP: 08106186 15:00 CHAN 2 DEG C. ====== 3.2 3. 1 3.1 3.0 3. 121 3. 1 3.2 3.5 3.6 3.9 4.10 3.9 3.4 3.5 3.2 3. Ill 2.9 2.8 2.8 3.0 3.2 3.3 3.5 3.6 .... C' ........ w 3.2 3.4 3.4 3.4 3.3 3.3 3.3 3.6 4.1 4.7 4.9 4.6 4.2 3.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== Q!6 I !Zl8/ 86 0Ql: 0121 !!16/!218/86 (212: 0Y.I ~!16/!218/86 1214: 1210 06/1!18/86 !216: !210 1216/(218/86 !218: 1210 s!I6/!ZI8/86 11!1: !.!HZ! !216/Y-18/86 12:00 1!16 I 1218 I 86 14: 0121 1216/1218186 16:1210 i2!6 I l2l8 I 86 18 : (210 1216/QIS/86 2f!S: 00 l!l6/Y.J8/86 22: 12H!I IZ!6/IZI9/86 121121:121121 !216/ !ZI9 I 86 !212: 0121 !!16/1219/86 1214:1210 06/!!19/86 !ll6: 00 !!16 I 1219 I 86 08: Q!Ql 06/!219/86 10:00 1!161!219/86 12: 12Ji21 06/09/86 14:00 l..il6 / !!19 I 86 1 6 : 121121 06/Ql9 /86 18:00 1116/09/86 20: 0121 1!16/09186 22:00 1216/ 1!!1 I 86 1210: 00 !!l6/ Hl/86 1212: 0!21 1216/10/86 04:00 ~96/ 1 Y.l/86 1216 : ~ll21 12.16/10/86 foilS: 00 iJJ6/l!!l/86 HI: Y.IQI £16/10/86 12:00 !216/HZI I 86 14 : 1210 1!16 I HI/ 86 1 6: !!1QI 1!16/ 1l!i186 18: !21121 V.l6/l.to/86 20:0121 1?.161 ll?.l/86 22: I!Hll BYTE RAW DATA --------------------227 87 89 229 85 86 231 84 85 233 82 83 235 82 83 237 82 84 239 82 84 241 83 86 243 84 87 245 85 89 247 86 89 249 85 87 DAILY AVERAGE VALUES 251 85 86 253 83 85 255 82 83 257 81 82 259 80 82 261 80 82 263 81 85 265 84 88 267 87 92 269 89 94 271 90 94 273 89 93 DAILY AVERAGE VALUES 275 88 91 277 87 88 279 85 87 281 84 86 283 83 85 285 83 84 287 83 86 289 86 91 291 91 97 293 94 11210 295 95 1f211 297 95 99 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 3.7 3.5 3.4 3.2 3.2 3.2 3.2 .,. .,. .._, . .._'\ 3.4 3.5 3.6 3.5 3.4 3.5 3.3 3.2 3.1 3.0 3.0 3.1 3.4 3.7 3.9 3.9 3.4 3.8 3.7 3.5 3.4 3.3 3.3 4.1 4.4 4.5 4.5 3.8 DATA FILE : RIFFLE03 START: 05129/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ====== 3.9 3.6 3.5 --.:_, . ...:;, 3.3 3.4 3.4 3.6 3.7 3.9 3.9 3.7 3.6 3.6 3.5 3.3 3.2 3.2 3.2 3.5 3.8 4.2 4.4 4.4 4.3 3.7 4.1 3.8 3.7 3.6 3.5 3.4 3.6 4. 1 4.7 5. li.l 5.1 4.9 4. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -----------------===== e16 I 11 I 86 !ZifZI: 1211!1 1!16/ 11 /86 !Zl2: 00 1!16/11/86 Q14!QIQI !!16/ 11/86 Ql6: 121121 1216/11/86 Ql8: Qlt!l ~!16/ 11 I 86 1121: 1Zil21 ~16/11/86 i2:1ZIIZI 06/11/86 14:0121 06/11/86 16:t!IQI i216/11/86 18:!21121 1216/11/86 20! 0121 1!16/11/86 22: 12H2i (!16/ 12/86 !210: IZIIZI (?6/12/86 1212: !liiZI 1216/ 12/86 1214: 01!1 1216/ 12/86 1216: J!IIZI 1!16/12/86 !218: 0QI Jil6/ 12/86 HI: 00 1!16/12/86 12:1!10 1!16/12/86 14: IZIQI !!16/12/86 16: 1!1121 1216/12/86 18:1210 !!16/12 / 86 21'21: 0121 06/12/86 22:121!21 1216/ 13 I 86 IZIQI: 01Zl 1Zl6/ 13/86 1212: 0121 1216/13/86 04: 01ZI 1!16/ 13/86 1216:121121 06/13/86 Lil8: 00 ~16 I 13/86 1!21: !21121 1!16 / 1 3 I 86 12: 0121 !!16/ i3/86 14:121121 (;)6/ 13/86 16: IZIQI 1216/ 13/86 18: 1!)!21 ~!16 / 13 I 86 2121: ~IY.l i!l6/13/86 22:12il!i BYTE RAW DATA --------------------299 93 95 31Zll 9121 91 31213 87 88 305 86 87 307 84 85 3fZI9 84 85 311 84 87 313 87 92 315 91 96 317 93 99 319 94 99 321 93 96 DAILY AVERAGE VALUES 323 91 93 325 89 9i?i 327 87 88 329 87 87 331 86 87 333 86 87 335 87 88 337 87 9121 339 88 93 341 91 96 343 92 97 345 92 96 DAILY AVERAGE VALUES 347 91 94 349 89 91!1 351 87 87 353 84 84 355 83 83 357 82 84 359 84 86 361 87 91 363 9Y.i 96 365 93 98 367 94 99 369 95 99 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 4.3 4. 121 3.7 3.6 3.4 3.4 3.4 3.7 4.1 4.3 4.4 4.3 3.9 4.1 3.9 3.7 3.7 3.6 3.6 3.7 3.7 3.8 4. 1 4.2 4.2 3.9 4.1 3.9 3.7 3.4 3.3 3.2 3.4 3.7 4.0 4.3 4.4 4.5 3.8 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 4.5 4.1 3.8 3.7 3.5 3.5 3.7 4.2 4.6 4.9 4.9 4.6 4.2 4.3 4.0 3.8 3.7 3.7 3.7 3.8 4.3 4.6 4.7 4.6 4.1 4.4 4.0 3.7 3.4 3.3 3.4 3.6 4.1 4.6 4.8 4.9 4.9 4.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 6 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TII"1E ======== ---------- 1216/1.4/86 0!21: 121!!! 1216114/86 !212:£21!21 £2!6/ 14/86 12>4: 00 '216 / 1 4 I 86 1216 : llll!l !216 I 14 I 86 Y.IB: 1!10 1!16/14/86 HI:&!HZl 1!16 I 1 4 I 86 12: 00 !!16/ 14/86 14:00 es6/14/86 16: 1t1.:1 12!6 I 14/86 18: 1!1121 06/14/86 2!!1: 01!1 !'.!16 I 1 4 I 86 22 : 00 !!56/ 1 5 l 86 IZU!l: !2i!!l !216/ 15186 02:1210 !!16/15/86 04: !lh!i J!f6 I 1 5 I 86 06: !!IllS i!l6/ 15/86 !218: 01!1 1!16/15/86 10:00 !!16 I 1 5 I 86 12: fll!2i 1!.16/ 15/86 14: },';(~) i!lb/15/86 !C.~!blil ilo/ i 51 3o 18~ !!::!(..i !li 6 / ). o .. l ~:~ 6 ~IJ ~?I ~ i!j i!i ~~l6; i0/56 i!l2: i!ll?.l m6/l6/86 lli4:1liio k.i6/ 16/86 !2i6; ~'l!;ij 1~.itj ,: J .. :_·, /;=Jb j ~!·: k:~~~-. ·:1.; .:.:J • ~::; / ;_::; tJ } :-~, ~ QJ t2i ;~it~,· 1 C! / ,:::~.::. i 4: t?S;;~i BYTE RAW DATA -------------------- 371 94 97 373 92 94 375 90 92 377 89 90 379 88 9121 381 88 9!!1 383 89 92 385 90 94 387 92 97 389 94 99 391 95 ·1fll0 393 96 10Ql DAILY AVERAGE VALUES 395 95 98 397 94 96 399 92 94 401 91 93 403 90 91 405 89 91 41217 'i-!:'1 94 41ll9 9 4 1 QH!l 411 HlQI U!i8 •+LS 105 11~5 415 Hil7 :l. i4 417 1i?.l6 1 HI DAILY AVERAGE VALUES 419 HJ2 11!15 421 99 1 ~IY.l 423 95 96 4·25 ·=t:.::; 9::~ 4 2-l· ? 1 c.-,:;:~ 429 91!) 92 4:::::1 ·::;IJ. Cj:;, 4:::::~; 96 :1 i!;2: L~ ::~ ~~ l. j~J J. 1 if.:t ;?' J~. ::::~ '}' J ~~j 5 J 1 ~;; CHAN 1 DEG C. ====== 4.4 4.2 4.0 3.9 3.8 3.8 3.9 4. t.<J 4.2 4.4 4.5 4.6 4. 1 4.5 4.4 4.2 4.1 4. 1!1 4. 121 4.4 5 .. J!) c: c:-..Jo..J 5. 7' 5.6 4-.o 5. 2. 4. ·:;; 4.5 4.3 4 n J. 4. i!'l 4. l 4.6 ,.... -;.~ ... , ... • • ·-.1 t:. . ......... .( DATA FILE : RIFFLE03 START: 05129/86 14:00 STOF': 08106/86 15:00 CHAN 2 DEG C. ====== 4.7 4.4 4.2 4. fll 4.0 4. 1:!1 4.2 4.4 4.7 4.9 5.0 5. fll 4.5 4.8 4.6 4.4 4.3 4. 1 4.1 4.4 5.0 5.8 6.3 6.4 6.0 5. i!i r:..~ r: ....J •.... J ::; • ki 4.6 4. :~; 4.:2 4. ::~ 4.5 .., ,, ... :• 5.2 ~LMS~~ PuwE~ A0ThO~IfY TEMP;Sr~G~ oTUDIES Dc-Jll~l :,t~;-;_:!:<.• p;_ .. ~: :OriThPC ....... Dl< ... '"'-\)o-l!l.l DEG C TEMP/TEMP RECORDER Page 7 12-!!12-87 DATA FILE . RIFFLE~I3 . .. ;i .... ~ 1 G ~-~-,__,~l<.c HYDRO PROJECT START: 1!15/29 /86 14:!210 J: .. i' .~.'. ::::. "/ >·<I 'v•EF\ -RIFFLE REACH STOP: i~l8/lll6/86 15:1!!1!1 CHAN 1 CHAN 2 DATE TIME BYTE RAW DATA DEG c. DEG c. --------=~=== ==== =========== ------====== -------------- 1!16/ 17/86 !211!1 : ill!!l 443 1!214 1!217 5.4 5.7 !!16/17 /86 1!12: 1211!1 445 1J2! 1 1J!I3 5.1 5.3 S!l6/ 17/86 1214: 0!2! 447 99 HI!Zi 4.9 5. Ql i!l6/ 17/86 !!16 : 1!11!1 449 97 99 4.7 4.9 i!l6/ 17/86 !..i:l8: 00 451 96 97 4.6 4.7 1!16/17 /86 1(11 : !!I !21 453 95 97 4.5 4.7 06/17/86 12: fll0 455 96 99 4.6 4.9 i!l6/ 17/86 14: 121121 457 99 104 4.9 5.4 !216/1 7/86 16:00 459 102 107 5.2 5.7 1!16/ 17/86 18:00 461 1!212 107 5.2 5.7 06/17/86 20:00 463 102 106 5 .., •-' 5.6 06/17/86 22: 01!1 465 10!21 11!13 5. 121 5.3 DAILY AVERAGE VALUES 4.9 5.2 !!16/18/86 !ll!ll: 1!10 467 99 101 4.9 5.1 !216/18/86 02:00 469 97 98 4.7 4.8 !!16/ 18/86 i214 : 1211!1 471 95 97 4.5 4.7 !216/ 18/86 1216: 0121 473 94 95 4.4 4.5 !?.16/18/86 08: 1!11!1 475 93 95 4 "'!" . ...;. 4.5 !!16/ 18/86 1 !() : !ZI!ll 477 93 95 4.3 4.5 !!16/ 18/86 12: 121121 479 93 96 4.3 4.6 1216/18/86 14:00 481 94 98 4.4 4.8 !!16/18/86 16: Y.l!!l 483 96 1121!!1 4.6 5.0 1!16/ 18/86 18:0121 485 98 lfZI1 4.8 5.1 1216/18/86 21!1: 1!10 487 98 101 4.9 5.1 !216/ 18/86 22: t!llll 489 97 100 4.7 5.0 DAILY AVERAGE VALUES 4.6 4.8 1Zi6/19/96 0Ql: J!Sill 491 96 98 4.6 4.8 1216/19/86 as2: 1!10 493 95 97 4.5 4.7 1!16/ 19/86 Ql4: kil0 495 94 95 4.4 4.5 QS6/ 19/86 ~16: 01ll 497 93 94 4.3 4.4 Ql6/ 19/86 1218: 1210 499 92 9 ...... _, 4.2 4.3 i!l6/19/86 11!1: QiQi 5131 91 93 4. 1 4.3 06/19/86 12: 12llll 51213 92 95 4.2 4.5 i!l6/19 /86 14: 0121 51215 95 10Ql 4.5 5.0 i!S6/l9/86 16: 0Jli 51217 99 105 4.9 5.5 1!16/19/86 1 s: 1!10 509 U212 11218 5.2 5.8 JZI6/19/86 2Jll: SZI!ll 511 103 HiS 5.3 5.8 !216/19/86 22: 121121 513 U!12 11216 5.2 5.6 DAILY AVERAGE VALUES 4.6 4.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- 06/ 2£l/ 86 1!11!1: 121121 12!6/2121/86 1!12: 0121 1!16/2121/86 1214: 01!j 1216/21!1/86 12'16: f2lf!l 1216/20/86 1!18: 12JIZI 1!16/2!21/86 HI: 0i!l 1!16/20/86 12:00 1216/21!1/86 14:0121 1216 I 21!1 I 86 16: 0Y.I f!l6/2!ll/86 18: i!l0 1!16/21!1/86 2£1! 00 1!16/2121/86 22:00 !216/21 /86 1211!1: 1210 fll6/21/86 02!00 1!16/21/86 04: 01!1 £16/21/86 1216: {210 ~!16/21 /86 08: 0(!1 !il6121 /86 10: 00 1!16/21 /86 12: 1.!1121 1216121186 14:0f21 1216/21/86 16:0121 1!16/21 186 18:00 !216121 186 20:0121 1!16/21 186 22: 0121 06 I 22 I 86 I!IJ.!J: 0121 £216/22/86 £12: 01ll 06/22/86 1214:00 !ZI6 I 22 I 86 1216: 00 06/22/86 e18: 0v.1 (216/22/86 H!i: f2llZI Qi6122/86 12:00 1216/22/86 14:1210 £!)6/22/86 16: "1QI !!16 I 22 I 86 18: !!1121 1!16/22186 2121: 1211.il V.l6/22/86 22:121121 BYTE RAW DATA ==== ========== 515 11210 1 !213 517 99 11!11 519 97 98 521 95 97 523 94 95 525 94 96 527 94 96 529 94 97 531 95 98 533 95 98 535 96 98 537 95 98 DAILY AVERAGE VALUES 539 95 98 541 95 97 543 94 96 545 94 95 547 93 95 549 93 95 551 93 95 553 94 97 555 94 97 557 95 98 559 95 99 561 95 98 DAILY AVERAGE VALUES 563 95 98 565 95 97 567 95 97 569 94 97 571 94 96 573 94 96 575 94 96 577 94 98 579 97 101 581 99 11215 583 10121 1 1215 585 100 11213 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 5.0 4.9 4.7 4.5 4.4 4.4 4.4 4.4 4.5 4.5 4.6 4.5 4.6 4.5 4.5 4.4 4.4 4.3 4.3 4.3 4.4 4.4 4.5 4.~ 4.5 4.4 4.5 4.5 4.5 4.4 4.4 4.4 4.4 4.4 4.7 4.9 5.0 5.121 4.6 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ====== 5.3 5.1 4.8 4.7 4.5 4.6 4.6 4.7 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.6 4.5 4.5 4.5 4.5 4.7 4.7 4.8 4.9 4.8 4.7 4.8 4.7 4.7 4.7 4.6 4.6 4.6 4.8 5.1 5.5 5.5 5.3 4.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- Ql6/23/86 !Zl0! !Zl0 l!i6/23/86 !212: 1!1121 06/23/86 !l.l4: 0f21 1!16 I 2 3 I 86 1!16 : 0!21 1216/23/86 m8: l!llll 1216/23/86 10:00 1.!16/23/86 12:1210 !216 I 23 I 86 14: !211!1 1216/23/86 16:00 06/23/86 18: 1!11!1 !ZI6/23/86 20: i!l!ll 1!16/23/86 22:00 1!16/24/86 0121: 121!21 1!16/24/86 1212:00 i£16/24/86 04: 121!21 06/24/86 06:00 .1!16 I 2 4/86 1!18: 121121 !216/24/86 1!21: 1210 !216/24/86 12: 1!1121 1216/24/86 14:1210 1!!6/24/86 16:0121 1216/2•+186 18:1210 1!!6/24/86 2k1: fll0 12!6/24/86 22: 1!1121 12!6/25/86 0!ZI: 1210 !!16/25/86 IZI2: 121!21 06/25/86 !214: 00 !!16/25/86 1216: 1!1{21 1216/25/86 08:121121 !216/25/86 1f21: 1211!1 Y-16/25/86 12:00 1!16/25/86 14:1210 1216/25/86 16: !Zl0 !!16/25/86 18: 01!1 Qi6/25/86 2121: QIJ21 !Zi6/25/86 22: fZI!21 BYTE RAW DATA ========== 587 99 102 589 98 1121121 591 97 99 593 96 98 595 95 97 597 95 97 599 95 98 601 96 100 603 99 104 605 10!21 104 607 100 103 609 100 1 !!12 DAILY AVERAGE VALUES 611 99 11211 613 97 99 615 96 98 617 95 97 619 95 96 621 94 96 623 95 98 625 96 99 627 96 10121 629 97 101 631 98 100 633 97 100 DAILY AVERAGE VALUES 635 97 99 637 96 98 639 96 98 641 95 98 643 95 98 645 96 98 647 97 100 649 99 11213 651 102 11219 653 105 112 655 107 112 657 1fZI6 111 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 4.9 4.8 4.7 4.6 4.5 4.5 4.5 4.6 4.9 5. !21 5.0 5.0 4.8 4.9 4.7 4.6 4.5 4.5 4.4 4.5 4.6 4.6 4.7 4.6 4.7 4.6 4.7 4.6 4.6 4.5 4.5 4.6 4.7 4.9 5.2 5.5 5.7 5.6 4.9 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 5.2 5.0 4.9 4.8 4.7 4.7 4.8 5.0 5.4 5.4 5.3 5.2 5.0 5.1 4.9 4.8 4.7 4.6 4.6 4.8 4.9 5. Ql 5.1 5.0 5.0 4.9 4.9 4.8 4.8 4.8 4.8 4.8 5.0 5.3 5.9 6.2 6.2 6.1 5.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page HI 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- 1216/26/86 121121:121121 1216/26/86 fil2:121121 !216/26/86 04: 0Y.I !?.16/26186 1216: J!lf21 1!16/26 186 1ll8: eu!l Ql6126186 Hi: 1!1121 06126186 12:00 06/26/86 14:1210 s216/26/86 16:00 1216/26/86 18: 1!11!1 06126186 2s!S: 00 1!16 / 26/86 22: 12!1!1 06 I 27 I 86 121t!l: 1!10 1!16/27/86 1!12: 01!1 !!16/27/86 lll4: !!1121 1!16127/86 !!16: 00 12l6/27/86 1218: f2ll21 06127/86 10:00 1216127/86 12: 121!21 1216127186 14:00 1!16127/86 16: l!li!l 1216/27/86 18:00 !!16 I 27 I 86 2!21: t:21121 06/27186 22:1210 06/28/86 00: 0!!1 !!16128/86 ~12: !!J!21 06/28/86 1214:00 1!16/28 I 86 !!16: 1!1121 06/28186 08:00 1216128/86 1121: 1!1121 06/28/86 12: 1!10 i!$6128/86 14:121121 1!16/28/86 16:0121 1!161 28/86 18: 1!Ho 1?)6128186 2121: lllf~ 1!16/28/86 22: Y.l!il BYTE RAW DATA ========== 659 105 109 661 103 11215 663 11211 103 665 99 11!11 667 99 100 669 98 11210 671 98 100 673 99 101 675 100 105 677 103 11:!19 679 106 112 681 106 111 DAILY AVERAGE 683 106 110 685 11215 108 687 11213 105 689 10 1 11212 691 99 100 693 99 100 695 99 103 697 103 108 699 11217 114 71211 110 116 7£13 111 116 71!15 110 114 DAILY AVERAGE 7!!17 109 112 709 107 1.1219 711 105 108 713 104 107 715 Hl3 106 717 lfZI3 106 71 9 104 11217 721 11214 1 1!18 723 11!15 108 725 11216 1 !!19 727 106 109 729 11216 1 V.19 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== 5.5 5.3 5.1 4.9 4.9 4.8 4.8 4.9 5. !9 5.3 5.6 5.6 5.1 5.6 5.5 5.3 5.1 4.9 4.9 4.9 5.3 5.7 6.0 6.1 6.0 5.4 5.9 5.7 5.5 5.4 5.4 5.4 5.5 5.6 5.6 5.6 5.5 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08106186 15:00 CHAN 2 DEG C. ====== 5.9 5.5 "" .,.. ..Jo..,) 5.1 5.0 5. 1!1 5.121 5.1 5.5 5.9 6.2 6.1 5.5 6. !!1 5.8 5.5 5.2 5. t:Zl 5. ItS 5.3 5.8 6.4 6.6 6.6 6.4 5.8 6.2 5.9 5.8 5.7 5.6 5.6 5.7 5.8 5.8 5.9 5.9 5.9 5.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== !!16/29/86 00: !!1!2! !!16/29/86 !!12: QS!{l 1!16/29/86 I?.S4:Y.l0 W6/29/86 !216: 01!1 1.!16/29/86 08:!!10 1!16/29/86 10:0121 1216/29/86 12:00 06/29/86 14: 1!10 !216/29/86 16:00 1!16/29/86 18:01!1 !216/29/86 2Y.i: 1210 Y.S6/29 186 22: 0f21 i!16/3f!l/86 !21l'f: !!10 fob I 3!21 I 86 1212: t!l0 !!16 / 31!1/86 1214: 121!21 fli6/$l!l/86 06; 0fll !!16/3fil/86 08: 1!1121 1216/30186 10: 1210 !216 I 31!1 /86 12 : !21121 1!16/:\J!I/86 14:0$!1 1!16/31!1/86 16: 121!21 ~2.16 I 3121/ 86 18: !210 12>613!21/86 21!1: 121121 !216130186 22: 00 !217 /01/86 00: 00 1217/l'Zil/86 1!12:0!!1 Ql//l!ll/86 04: !21!21 1!17 I !211/86 1!16: 1!1!21 1!17 I !!11 I 86 !!18: 1211!1 07/J!l1/86 1121: !210 1!17 /Ql1/86 12:0121 1!17 1 i!l1 /86 14 : ese1 !217/1!11/86 16:01!1 !!17 /l!ll/86 18: 1211!1 1217 h'H 186 2121: 0!!1 1!17 I ill1 /86 22: 1210 BYTE RAW DATA ========== 731 106 108 733 105 11217 735 104 105 737 102 11214 739 11212 11!14 741 11212 104 743 102 105 745 lt..iJ4 H!l8 747 Hl7 111 749 1!219 113 751 109 114 753 HiS9 113 DAILY AVERAGE VALUES 755 109 111 757 107 109 759 11216 11!18 761 104 106 763 104 105 7 65 11214 106 767 11!14 Hl7 769 107 111 771 111!1 116 773 113 119 775 114 12!ZI 777 114 118 DAILY AVERAGE VALUES 779 112 114 781 1HI 111 783 108 109 785 107 109 78"7 107 11219 789 107 1lil8 791 Hl7 Hl9 793 107 110 795 107 111 797 1!218 112 799 109 112 801 HIS9 111 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 5.6 5.5 5.4 5.2 5.2 5.2 5.2 5.4 5.7 5.9 5.9 5.9 5.5 5.9 5.7 5.6 5.4 5.4 5.4 5.4 5.7 6.121 6.3 6. 4_ 6.4 5.8 6.2 6.0 5.8 5.7 5.7 5.7 5.7 5.7 5.7 5.8 5.9 5.9 5.8 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 5.8 5.7 5.5 5.4 5.4 5.4 5.5 5.8 6. 1 6.3 6.4 6.3 5.8 6.1 5.9 5.8 5.6 5.5 5.6 5.7 6.1 6.6 6.9 7. 1!1 6.8 6.1 6.4 6.1 5.9 5.9 5.9 5.8 5.9 6. 1!1 6.1 6.2 6.2 6.1 6. 121 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 12 12-1!12-87 BRADLEY LAI<E HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T I 1'1E ======== ---------- 07 /12!2/86 00: 1!10 !217 I V.:S21 86 fll2: IZIIZI Ql7 /!!12/86 Ql4: 00 i!17 I 1212/86 1216: 1!11!1 !.217 /1!12/86 08: 00 1!17/1212/86 1f21:00 1!17 /1212/86 12:1210 1!17 /02/86 14:0121 1217 /!.!12/86 16:1210 1217/1212/86 18:00 1!17 /02/86 20:S.~0 1217/1212/86 22: IZH!I !!17 /1!13/86 IZH!I: 0~1 Y.l7 /03/86 02: 01!1 1.217 I 1!13 I 86 1214: 01ll 1217 /!213/86 1!16: f!i0 1217 /1!13/86 1218: 0fZI Ql7 /!!13/86 10: 0!!1 Ql7 /1.!13/86 12: 0i!l !217/03/86 14:01!1 !!17/IZ13/86 16:00 !!17 /03186 18:00 f!l7 11213186 2121: 01!1 IZI7 1!213186 22: 0!21 1!17 I !?.i4 I 86 1!10: Qlf!l £!17 11214/86 02: 1!11!1 07/04/86 04:00 1!17 /1214/86 1!16: 0121 07/1214/86 es8: 00 1!17 I !214 / 86 10: IZIIZI !217 /!!14/86 12: 00 Ql7 I !214 I 86 14: !MI 1!17 /{14/86 16: !!10 1!17 /1!14/86 18: !211!1 07 I 1214 /86 21!1: f2I!ZI 1!17 I l!i4 /86 22: QIQI BYTE RAW DATA ========== 81213 11218 111ZI 8Y.l5 11!16 11!18 807 105 106 8!219 11213 105 811 11.113 1 06 813 11!14 11li7 815 105 108 817 Hl6 108 819 106 109 821 11!16 11!21 823 11217 111 825 107 11!21 DAILY AVERAGE VALUES 827 107 109 829 105 1 !iJ7 831 104 105 833 103 11ZI4 835 102 11214 837 102 103 839 102 11215 841 105 110 843 109 113 845 110 115 847 111 115 849 111 114 DAILY AVERAGE VALUES 851 109 111 853 108 109 855 106 11'!18 857 11!16 108 859 105 107 861 105 107 863 105 108 865 U!18 112 867 111 116 869 113 119 871 115 12121 873 114 118 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 5.8 5.6 5.5 5.3 5.3 5.4 5.5 5.6 5.6 5.6 5.7 5.7 5.5 5.7 5.5 5.4 5.3 5.2 5.2 5.2 C" C" ..Jo..J 5.9 6.0 6.1 6.1 5.6 5.9 5.8 5.6 5.6 5.5 5.5 5.5 5.8 6.1 6.3 6.5 6.4 5.9 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06186 15:00 CHAN 2 DEG C. ====== 6. e1 5.8 5.6 5.5 5.6 5.7 5.8 5.8 5.9 6. J!i 6.1 6. !21 5.8 5.9 5.7 5.5 5.4 5.4 5.3 5.5 6.0 6.3 6.5 6.5 6.4 5.9 6.1 5.9 5.8 5.8 5.7 5.7 5.8 6.2 6.6 6.9 7. !!l 6.8 6.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 13 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 07/1215/86 $21121:0121 !!17 /1215/86 1212:121121 9.17/1215/86 04: 0121 !!I 7 I 05 I 86 !!16 : !21!21 07/1215/86 !218: 00 !2!7 /!215/86 10: 1!1121 !217 /1215/86 12: 1!1121 07105186 14:j!Ho 07 /1.!15/86 16:0121 i217 /!215/86 18: 0!21 ;257 /!2l5/86 20: 00 1217/05/86 22: @21 Y-17 /1!16/86 ~tHo: 121121 1217/06/86 02: 00 1217/1216/86 04: 1211!1 !217 /s!l6/86 06: !210 07/06/86 Ql8:r210 !217 /1216/86 10: 01!1 ~!17/06/86 12:1210 !217/06/86 14:00 !!17 /06/86 16: lll!ll es7 /!216/86 18: 00 07/!216/86 20: 0f2l 1.!17 I !216/86 22: 00 1217/07/86 1211.!1: $210 ~!17 I 12.17 I 86 02: J!lel 07/1!17 /86 04:1.~10 lo7 /'2.!7 /86 1216: !ZIQI 07 I f!.l7 I 86 1218: !210 197/lil7 /86 11!1: 1211!1 1!17 /07/86 12:00 07 1!217 I 86 14: 1!10 07 /!!17 /86 16: 0!Zl 1!17 /!!17 /86 18: I?Jili 1!17 /l!i7 /86 2J!l: !!lt!l !!17 /IJ.I7/86 22: !!!Ill BYTE RAW DATA ==== ========== 875 113 115 877 111 113 879 11121 111 881 1 08 11!21 883 107 109 885 107 112!9 887 HIS 111 889 1 HI 113 891 111 114 893 111 115 895 112 115 897 112 115 DAILY AVERAGE VALUES 899 112 114 91l11 111 112 903 111!1 112 9!95 110 112 907 H19 111 909 11!19 111 911 109 111 913 Hl9 112 915 11121 112 917 111 114 919 111 115 921 112 115 DAILY AVERAGE VALUES 923 111 113 925 11flJ 112 927 110 112 929 109 111 931 11!19 111 933 11!18 11!!1 935 H>B 111 937 11219 112 939 110 112 941 111 114 943 112 116 945 112 115 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.3 6.1 6. I!S 5.8 5.7 5.7 5.8 6. 121 6.1 6.1 6.2 6.2 6.0 6.2 6.1 6.121 6. !21 5.9 5.9 5.9 5.9 6. 121 6.1 6.1. 6.2 6. Ill 6.1 6.0 6.0 5.9 5.9 5.8 5.8 5.9 6.0 6.1 6.2 6.2 6.0 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ====== 6.5 6.3 6. 1 6. Ill 5.9 5.9 6.1 6.3 6.4 6.5 6.5 6.5 6.3 6.4 6.2 6.2 6.2 6.1 6.1 6.1 6.2 6.2 6.4 6.5 6.5 6.3 6.3 6.2 6.2 6.1 6.1 6.0 6.1 6.2 6.2 6.4 6.6 6.5 6.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 14 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== Qi7/12l8/86 1!1!21: 1210 V.l7 1!218/86 !212: !!Sl21 1217/1?.18186 04: 0l!l !217 1!218186 !216: QltZI 07 I t.il8 I 86 1218: i!J!Zl !!17 /1!18/86 1!21: !210 07 1!218186 12: ~10 1!17/~18/86 14: 1!1121 1!17/1!18186 16:00 !ZI7 I !218 I 86 1 8: !!hZI Y-17 108186 20: !210 1!17 I Y-18 I 86 22: 1!11£1 1117 /1219 / 86 1210: \11121 07/ Ql9 I 86 1112: 0!21 t!l7 I lil9 I 86 1214 : 0121 121711219/86 06: !21!21 (!17/!219186 !218:121!21 !217 109186 HI: 00 !!17 I !!19 I 86 12: Q'!QI 0711219/86 14!00 121711219/86 16: IZIQI 1!17 1!!19/86 18:00 t!I7/QS9186 21!1:1!11!1 1!17/t!l9/86 22: 0121 ~!17 I 1.$!5186 0121: 1!1121 !217 I HI/ 86 02: 0f21 Y.l7 I lt!l/86 1!14: 1!10 137/1121/86 06: 00 !217/1Q1186 1ZI8:l210 1!17/10186 10!Y.I!ZI 1!.17/1125/86 12: 0!!1 !!17 I Hl/86 14: 00 1217 I lQI/86 16:0121 !!57 I ll!l/86 18: 01!1 07 /1!21 I 86 20: s21!21 1!17/ Hl/86 22: I!HZI BYTE RAW DATA ========== 947 112 115 949 111 113 951 11!21 112 953 109 111 955 109 111 957 litiS 111 959 109 111 961 110 113 963 112 116 965 113 118 967 114 119 969 114 117 DAILY AVERAGE VALUES 971 113 116 973 112 115 975 112 113 977 111 113 979 111 112 981 110 112 983 111 113 985 112 115 987 113 117 989 114 119 991 115 119 993 115 117 DAILY AVERAGE VALUES 995 114 116 997 112 113 999 111 112 h101 1 09 11121 1 J!l03 HIS 108 10!!15 107 11218 li!H?I7 11!17 11121 1 !Zl!!l9 109 112 H!l11 111 115 Hl13 113 117 11ZI15 114 119 H:l17 114 117 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.2 6.1 6. '!S 5.9 5.9 5.8 5.9 6.0 6.2 6.3 6.4 6.4 6.1 6.3 6.2 6.2 6. 1 6.1 6.0 6.1 6.2 6.3 6.4 6.~ 6.5 6.2 6.4 6.2 6.1 5.9 5.8 5.7 5.7 5.9 6.1 6.3 6.4 6.4 6.1 DATA FILE : RIFFLE03 START: 05129/86 14:00 STOP: 08106/86 15:00 CHAN 2 DEG C. ====== 6.5 6.3 6.2 6.1 6.1 6.1 6. 1 6.3 6.6 6.8 6.9 6.7 6.4 6.6 6.5 6.3 6.3 6.2 6.2 6.5 6.7 6.9 6.9 6.7 6.5 6.6 6.3 6.2 6.0 5.8 5.8 6. 121 6.2 6.5 6.7 6.9 6.7 6.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ===== ~17 / 11/86 01!1: 00 1217/11/86 02:1!1!21 07/11/86 1214:1210 !217/11 /86 1216: lll0 1()7/11/86 08:00 Ql7/11/86 Hl:l!l$21 1217 I 11/86 12:00 f217 /11 /86 14: lli!Zl 1217 I 11/86 16:00 i!i7/11/86 18:£1121 Ql7 I 11/86 2121:00 ~:!17 I 11/86 22: 121£1 ~!17 I i 2/86 121V.I: f!ll21 07 I 12/86 IZ12: 0121 1217/ 12 I 86 1214: 0121 i!l7/12/86 06:1!10 1217/12 I 86 08: 121!21 07/ 12/86 1121: 1210 1217/12/86 12:i21QI 07/12/86 14:00 S!l7 /12/86 16: Y.ll!i 1217/12/86 18:1210 ~!17 /12/86 2121: 0121 1217/12/86 22:0121 1217/13/86 121{21: 00 Y-17/13/86 I212:1Zh!l !217/13/86 1!14: ~11!! l:i!7 /1 3 I 86 1216: 121~1 1217/13/86 !!18:00 s!l7/i3/86 11!1:00 1!17/13/86 12:00 f!l7/13/86 14a1!21 121'7/13/86 16:01!1 1217 / 1 3/86 18: !Zlt!l Y.l7 / 13/86 20: 1!1!!1 1217/ 13/86 22: li!lf!l BYTE RAW DATA --------------------Hl19 113115 1021 112 113 112123 11!21 111 1025 11219 11121 1fll27 108 110 11!129 11!18 11219 1031 109 111 112133 110 11 4 112135 113 11 7 1 !v37 114 1 1 9 1039 115 119 Hl41 115 117 DAILY AVERAGE 1043 113 115 11l145 112 113 112147 110 111 11!149 11219 110 112151 108 1lll9 U153 1f217 109 112155 109 111 112157 110 113 l!ll59 112 116 1061 113 117 1063 114 117 1065 113 116 DAILY AVERAGE 1067 112 115 1069 112 114 112171 112 113 112173 111 112 Hl75 110 112 11?177 1 HI 112 1Ql79 1 HI 112 1!2181 1 HI 11 2 1083 111 113 1QI85 112 114 11!187 112 115 H!l89 113 115 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== 6 ..,. •w 6.2 6.0 5.9 5 .. 8 5.8 5.9 6. t21 6.3 6.4 6.5 6.5 6.1 6.3 6.2 6. 121 5.9 5.8 5.7 5.9 6.0 6.2 6.3 6.4 6.3 6. 1 6.2 6.2 6.:2 6.1 6.0 6. !!l 6. Ql 6.0 6.1 6.2 6.2 6.3 6.1 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 6.5 6.3 6.1 6.l!l 6. 121 5.9 6.1 6.4 6.7 6.9 6.9 6.7 6.4 6.5 6.3 6.1 6.0 5.9 5.9 6.1 6.3 6.6 6.7 6.7 6.6 6.3 6.5 6.4 6.3 6.2 6.2 6.2 6.2 6.2 6.3 6.4 6.5 6.5 6.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== fl!7 I 14 I 86 121121: 0121 Ql7 I 14/86 02: flit!! 1217 I 14/86 !li4: 00 ~!17 /14/86 f216: 1!1!!1 1!17 I 14/86 08:0121 f217 I 14 I 86 11!1 : fltl'il I!J7/14/86 12:0121 1!17/14/86 14:0121 1!17 I 14/86 16: 01!1 1217/14/86 18:1~12! 1217/14/86 21!1:1!Hll Ill? /14/86 22: 0!21 12!7 /15/86 f2ll!l: 0!.!1 1~17/15/86 {1.12:121&!1 1217 I 15 I 86 !214: S!h!l !217 /15 I 86 f216: 0121 1!17/15/86 1!18:121!21 1217 I 15/86 10: 0121 1!17/15/86 12: 00 07/15/86 14:00 !!17/15/86 16:0121 1217/15/8618:00 1!17/15186 20:01!1 l2i7 I 15186 22: 0!i.l 1217 I 16/86 flll21: QIY.l lZ17 I 16/86 02: 121121 !~17 I 16/86 Y.l4: 00 1217 I 16/86 06: 0!21 !2l'7 /16/86 !!18: 00 1!17 I 16/86 if!l: 0121 (il//16/86 12:00 !!17/16/86 14:1211!1 !ll7 I 16/86 16:00 J!i7 /16/86 18:00 !!.17 / 16/86 21ll: IZIY.l i!J7 I 16/86 22: 1210 BYTE RAW DATA ==== =========== 112191 112 115 11!193 112 113 1095 111 113 1097 11121 112 112199 109 111 111211 109 110 1103 109 111 1105 111 115 111217 11 5 120 1109 119 126 1111 124 131 1113 125 131 DAILY AVERAGE VALUES 1115 125 131!1 1117 125 128 1119 123 126 1121 122 125 1123 122 124 1125 121 124 1127 121 124 1129 121 124 1131 122 125 1133 122 125 1135 123 126 1137 123 125 DAILY AVERAGE VALUES 1139 122 125 1141 122 124 1143 121 123 1145 120 123 11 4 7 12121 122 1149 12121 122 1151 119 122 1153 121!1 123 1155 120 123 1157 12121 123 1159 120 123 1161 1212! 121 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.2 6.2 6.1 6.0 5.9 5.9 5.9 6.1 6.5 6.9 7.4 7.5 6.4 7.5 7.5 7.3 7.2 7.2 7.1 7.1 7.1 7.2 7.2 7.3 7.3 7.3 7.2 7.2 7.1 7.0 7.0 7 .Ill 6.9 7. !21 7.0 7.0 7.0 7 .Ill 7.0 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 6.5 6.3 6.3 6.2 6.1 6.0 6.1 6.5 7.0 7.6 8.1 8.1 6.7 8. l!l 7.8 7.6 7.5 7.4 7.4 7.4 7.4 7.5 7.5 7.6 7.5 7.5 7.5 7.4 7.3 7.3 7.2 7.2 7.2 7.3 7.3 7.3 7.3 7. 1 7.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- 1!!7 I 17/86 12H?.I: 00 07 I 17/86 t!12: 1!11!1 07 I 17/86 !!14: 1210 1!17 I 17/86 1!!6: 121121 1!17 I 17/86 08: 1!1121 137 I 17/86 HI: 0121 07 I 17/86 12: !2Ho !!17 I 17/86 14:00 07 I 17/86 16: l!IY.I i!l7/17/86 18:0121 fl..l7 I 17/86 20:00 !!17 /17/86 22: f!ll21 1217/18/86 !210!!2iiZI 1217/18/86 1212: 1210 1217/18 I 86 1214: 121121 07 I 18/86 !216: 0121 1217/18/86 1218: 0!21 1217/18/86 HI: 1!10 Y.17/18/86 12: 1211!1 IZI7/18/86 14! 00 1!17 I 18/86 16:1210 07/18/86 18:0121 1!17 I 18/86 20: 1!10 1~17/18/86 22:1210 12111 1 9/86 e10: 121!!1 07/19/86 02:Qll!l 07 I 19/86 !!14: 1210 1!17 /19/86 1216: 0121 J!l7 / 1 9 /86 08: ,;0 !!17 / 19/86 11!1: !Zl!ZI 07/19/86 12:00 07/19/86 14:0!!1 1117/19/86 16: fZIQI 1!17/19/86 18: 1!1!!1 1217/19/86 2t!l:l!l!!l !?.17 /1 9/86 22: 1!1!21 BYTE RAW DATA ==== ========== 1163 119 120 1165 117 118 1167 116 116 1169 114 115 1171 113 113 1173 112 112 1175 112 113 1177 113 116 1179 116 120 1181 119 123 1183 120 124 1185 120 122 DAILY AVERAGE 1187 119 120 1189 117 118 1191 115 116 1193 114 115 1195 113 114 1197 113 114 1199 113 115 1201 114 118 1203 117 121 1205 119 123 1207 12121 123 1209 119 122 DAILY AVERAGE 1211 1213 1215 1217 1219 1221 1223 1225 1227 122'7 1231 118 120 117 119 116 117 115 116 114 115 113 115 114 116 116 120 119 124 122 127 123 127 1233 123 125 VALUES VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.9 6.7 6.6 6.4 6.3 6.2 6.2 6.3 6.6 6.9 7.0 7. 121 6.6 6.9 6.7 6.5 6.4 6.3 6.3 6.3 6.4 6.7 6'!9 7.~ 6.9 6.6 6.8 6.7 6.6 6.5 6.4 6.3 6.4 6.6 6.9 7.2 7.3 7.3 6.8 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 7.0 6.8 6.6 6.5 6.3 6.2 6.3 6.6 7. ~~ 7.3 7.4 7.2 6.8 7.0 6.8 6.6 6.5 6.4 6.4 6.5 6.8 7.1 7.3 7.3 7.2 6.8 7. ~~ 6.9 6.7 6.6 6.5 6.5 6.6 7. fll 7.4 7.7 7.7 7.5 7.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 18 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T I 1'1E ======== ---------- i217 I 2121 I 86 I{)J!I: iZIQl !!17 I 2121/86 1212: Y-l!Zl 1!17/2£1186 Ql4:0!21 i217 /2!21/86 !216: 1Zll2l Ql7 /2Ql/86 1218:121121 1!17 I 21!1 I 86 Hi: Qlf2i 1217 l2j!l/86 12:121121 J!17 /2121186 14:19121 !!17/2121/86 16:~H!l J!l7 /21!1/86 18:121121 1:.'?7 12121/86 20:00 !!17 I 2121 I 86 22: 01!1 ~!17 /21 I 86 Jc!Si21: 1~1!21 1Zl7/21/86 1212:1210 !217 /21/86 Y.14: 1,!1121 !217/21/86 06:1210 1Zi7 /21/86 08: 1!1121 07/21/86 10:00 !!17 /21/86 12: 12H!I 1.!17/21/86 14:010 !!17 /21/86 16: l!if21 £17/21/86 18: 10121 i!17 /21 / 86 2121: !!iV.I 07/21/86 22: 12H!l 1!.17 /22/86 1!10: {!10 12!7/22/86 1212: l!l!ZI 07/22/86 04 :t.!l0 1!17/22/86 !216: 0121 W-17 /22/86 1!18: 00 !Zi 7/22/86 l!ll : 0!!1 07/22/86 12:0121 i!!7/22/86 14:00 1217/22/86 16: 01!1 iZ17 /22186 18: 1!11!1 !!17 /22/86 2!!1: IZII21 i!/7/22/86 22: l!l!2i BYTE RAW DATA ========== 1235 122 124 1237 1239 1241 1243 1245 1247 122 123 123 123 123 125 126 126 126 125 127 1249 124 128 1251 125 129 1253 126 13121 1255 126 13121 1257 126 129 DAILY AVERAGE 1259 1261 1263 1265 1267 1269 1271 1273 125 128 124 126 123 125 122 124 121 122 120 122 120 121 120 124 1275 122 125 1277 123 126 1279 123 126 1281 123 126 VALUES DAILY AVERAGE VALUES 1283 123 126 1285 123 125 1287 123 127 1289 125 129 1291 125 128 1293 125 129 1295 125 129 1297 125 129 1299 126 130 13$!!1 127 13fll 1303 127 130 13i!j5 127 130 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.2 7.2 7.3 7.3 7.3 7.3 7.3 7.4 7.5 7.6 7.6 7.6 7.4 7.5 7.4 7.3 7.2 7.1 7.0 7. 121 7.0 7.2 7.3 7.3 7.3 7.2 7.3 7.3 7.3 7.5 7.5 7.5 7.5 7.5 7.6 7.7 7.7 7.7 7.5 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 7.4 7.5 7.6 7.6 7.6 7.5 7.7 7.8 7.9 8. «!I 8. Ql 7.9 7.7 7.8 7.6 7.5 7.4 7.2 7.2 7. 1· 7.4 7.5 7.6 7.6 7.6 7.5 7.6 7.5 7.7 7.9 7.8 7.9 7.9 7.9 8. Ql 8. Ill 8.0 8.1!!1 7.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-~1.1 DEG C TEMP/TEMP RECORDER Page 19 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== !117 /23/86 0!21: ti10 1?17 /23/86 1212: s!liZI 07/23/86 04:!2H!I iZ17 I 2::.~ /86 l216: 121121 1217/23/86 t218: !21121 !!17 I 23/ 86 1121: 121i21 !!17 /23/86 12:00 1!17 /23/86 14: 0121 !!17 /23/86 16: 00 !217/23/86 18: l!li!l 0"7 /23/86 2~1: 1210 1!17 /23/86 22: l!l!!l i217 /24/86 !!11!1: 1.!10 07/24/86 IZ12: !210 i!17 /24/86 04: 1211!1 1217/24/86 06:00 ~217 I 2 4 I 86 1218: 0121 !217 /24/86 HI: 0!21 !217 /24/86 12: !!1121 07/24/86 14: 0{:!1 1!17/24/86 16:0i!l !!.17 /24/86 18: 1211!1 IZ17 /24/86 20: 1!11!1 !2l7 /24/86 22: 01!1 1!17 /25/86 1!10: 01.!1 1!17/25/86 02: 0121 07/25/86 04:00 07/25/86 1216: 1!1!21 !217 /25/86 !218: 1!!0 !217/25/86 HI: 1!1!!1 !!17 /25/86 12: 0!21 !217/25/86 14:!210 !217/25/86 16:J!l0 ~!17 /25/86 18: !21!21 1117/25/86 2!21: !3!21 1!17 /25/86 22: !9!21 BYTE RAW DATA --------------------131217 126 129 131!19 125 128 1311 125 127 1313 125 127 1315 1317 1319 1321 1323 1325 1327 1 '")1:" "-'-' 127 124 126 124 127 125 128 126 129 127 13!21 128 131 1329 127 13!21 DAILY AVERAGE VALUES 1331 127 13f!l 1333 127 129 1335 126 128 1337 125 127 1339 125 126 1341 124 125 1343 123 125 1345 123 125 1347 124 126 1349 124 127 1351 124 125 1353 123 124 DAILY AVERAGE VALUES 1355 1357 1359 1361 1363 1365 1367 1369 1371 1373 121 122 12i!l 12£1 119 119 118 119 118 120 119 121 121 123 121 124 123 125 123 125 1375 124 125 1377 123 125 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.6 7.5 7.5 7.5 7.5 7.4 7.4 7.5 7.6 7.7 7.8 7.7 7.6 7.7 7.7 7.6 7.5 7.5 7.4 7.3 7.3 7.4 7.4 7.4 7.3 7.5 7.1 7.0 6.9 6.8 6.8 6.9 7.1 7.1 7.3 7.3 7.4 7.3 7.1 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ====== 7.9 7.8 7.7 7.7 7.7 7.6 7.7 7.8 7.9 8. 121 8.1 B. Ill 7.8 8.0 7.9 7.8 7.7 7.6 7.5 7.5 7.5 7.6 7.7 7.5 7.4 7.6 7.2 7.0 6.9 6.9 7.0 7.1 7.3 7.4 7.5 7.5 7.5 7.5 7.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 212! 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----------------===== 07/26/86 l!l!2i: 12~!!1 Ql7 /26/86 !212: !21!!1 Ql7 /26/86 Ql4: 1210 1!17 /26/86 1!16: l!H!i 1!17 /26/86 12~8: fZH21 !'217 /26/86 10: j.!112l 12i7 /26/86 12: Qh!l fil7/26/86 14:00 07/26/86 16:121121 l!l7 /26/86 18! l2lY.I 07/26/86 20: 1!1!21 07/26/86 22: 1!10 !217/27/86 12HZI:0QI !!17/27 /86 !212: 0!21 i!17 /27/86 !214: i-!ll!l !217 /27/86 06: IZI!!l i217 /27/86 1!18: !211!1 !217/27/86 HI: 0121 1!17 /27/86 12: l!lfZI 07/27/86 14:1!10 1!17 /27/86 16: Y.H!I 07/27/86 18!00 i?t7/2~7 /86 21!1:1!10 !217 /27/86 22: ~10 07/28/86 !!H!l: 00 !2~7/28/86 ll12: 121!21 !'217 /28/86 1214:00 !!17 I 28/86 !!16: l!lf!l C!.i7 /28/86 1!18: 121121 i!l7/28/86 11!1: 01!1 1?17 /28/86 12: 1{)121 !!17/28/86 14:1210 Y.J7 /28/86 16: 121!21 07/28/86 18:0121 1217/28/86 21!1: 0121 1217/28/86 22: 12~121 BYTE RAW DATA ==== ========== 1379 122 125 1381 122 124 1383 122 123 1385 121 123 1387 121 123 1389 121 123 1391 121 123 1393 122 125 1395 124 128 1397 125 129 1399 125 128 1401 124 126 DAILY AVERAGE VALUES 1403 141ZI5 141217 14Y.19 1411 1413 1415 1417 1419 1421 123 124 121 121 118 118 117 116 116 115 115 116 115 116 117 120 119 123 121 124 1423 122 125 1425 122 124 DAILY AVERAGE VALUES 1427 121 123 1429 120 121 1431 119 120 1433 117 118 1435 117 118 1437 117 118 1439 117 119 1441 119 123 1443 123 127 1445 125 131 1447 128 132 1449 129 132 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.2 7.2 7.2 7.1 7.1 7.1 7.1 7.2 . 7. 4 7.5 7.5 7.4 7.3 7.3 7.1 6.8 6.7 6.6 6.5 6.5 6.7 6.9 7.1 7.2 7.2 6.9 7.1 7.0 6.9 6.7 6.7 6.7 6.7 6.9 7.3 7.5 7.8 7.9 7. 1 DATA FILE : RIFFLE03 START: 05/29/86 14:00 STOP: 08/06/86 15:00 CHAN 2 DEG C. ------------ 7.5 7.4 7.3 7.3 7.3 7.3 7.3 7.5 7.8 7.9 7.8 7.6 7.5 7.4 7.1 6.8 6.6 6.5 6.6 6.6 7. 121 7.3 7 .. 4 7.5 7.4 7. Ql 7.3 7.1 7.0 6.8 6.8 6.8 6.9 7.3 7.7 8. 1 8.2 8.2 7.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-!21.1 DEG C TEMP/TEMP RECORDER Page 21 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- tii7 /2 9 I 86 I!H!l: Qli!S 1!17/29/86 {!12:1!11!! (17 /29/86 1!14: 00 Y.l7 /29/86 1!16: i!H!i (!17 /29/86 1218: 1210 ~!17 /29/86 10: IMI 12!7 /29/86 12: 01!! 1!17 129/86 14: illiZI 1217/29/86 16: 00 ~217 I 29 I 86 18: 12112! Ql7 129/86 20:1210 1!17 /29186 22: !Zil!l 1217 I 3121 I 86 0l!l: 0!!1 07 /3!21186 1Zl2: 012! l!l7 / 3~1 I 86 !214: t!\1!1 Y-17 /30 I 86 1216: 00 {!17 / 31!1 I 86 1218: 01!! !!>7 /3il!/86 10:00 1~7 I 31!11 86 12: 12M Ql7 13121186 14! 1210 Ql7 /3V.1186 16: 1!1121 1!!7 130/86 18: 0!!1 1!17 I 31!1/86 2!!1: 1!1121 07 /31!i/86 22: V.ll21 BYTE RAW DATA ==== ========== 1451 128 131 1453 127 13l!! 1455 126 128 1457 125 124 1459 123 125 1461 124 126 1463 125 129 1465 128 133 1467 131 136 1469 132 137 1471 132 136 1473 131 134 DAILY AVERAGE VALUES 14 75 1 3121 132 1477 129 131 1479 128 1312! 1481 127 125 1483 167 129 1485 21!18 1 :::.~ 1 1487 210 133 1489 211 134 1491 211 133 1493 210 132 1495 2!.;}9 131 1497 209 131!1 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.8 7.7 7.6 7.5 7.3 7.4 7.5 7.8 8.1 8.2 8.2 8.1 7.8 8.0 7.9 7.8 7.7 11.7 15.8 16.0 16.1 16.1 16.0 15.C( 15.9 12.9 DATA FILE : RIFFLE03 START: 05/29186 14:00 STOP: 08106186 15:00 CHAN 2 DEG C. ====== 8.1 8.0 7.8 7.4 7.5 7.6 7.9 8.3 8.6 8.7 8.6 8.4 8.1 8.2 8.1 8.121 7.5 7.9 8.1 8.3 8.4 8.3 8.2 8.1 8.0 8. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-1213-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH BEGIN OBS :NEW BATTERIES; CHAN1=8.1; CHAN2=8.3 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:~~ END OBS :CHAN1=6.9; CHAN2=6.7; ERRORS=0; USED=1315 DATE TIME ..... _,______ ------------------ ll/8/!?17/86 17!1!10 1!18/!217/86 19:121121 f218/IZ17/86 2i: il!!l 1!18/1217 /86 23: !!11!1 Y.18/Y.I8/86 12!1: !!1121 QIB/!218/86 03: !211!1 i!.IB / 1!18/86 05: ~!HZ! !218/1218/86 !217: f21f2i I!I8/Q58/86 1219: 0!21 1218/!218/86 11: f21ill !Zl8/i!l8/86 13: f!IY.I 1218/!!18/86 15: 0!1.1 1!18/!!18/86 17: r21~:1 1!18/QIB/86 19: flll!l !218/1218/86 21:121121 ~18/!218/86 23: !21~1 ~~18/f~/9/86 1211 : 00 !{18/!219/86 1!13: 1!1121 IllS/ 121-=i' I 86 !215! !21~!1 i!I8/!ZI9 / 86 fZI7: V.1!21 !?.18 / !219 I 86 ~19: 0121 Y.l8/lZJ9/86 11: !21121 Ql8h1.19/86 13: !210 ~!18/fl9/86 15:0121 ll.l8/lll9/86 17:1!10 1!18 / !219 I 86 1 9: 12!!21 Ql8/J!I9/86 21: 0!21 1218/1!!9 /86 23: !ZHZl Y.l8/ Hl/86 Y.l1: !21!li l.:>El I 1!21/86 ~!13: !21~21 ~218/ 1QI/86 1215: 1!1!.?1 1!18/ 1.$?1/86 Ql7: Y.iQI i!IB/ 1 !!1/86 i219: I!H!I ~:18/ Hl/86 11: 1!1!21 QlEL/ l!Zl /86 13: illlll 1!18/ Hl/86 15: ill!~l !218 I U!~ /86 1 7: l!IY.I {!18/ 11!1/86 19: !21!21 Ql8/ Hl/86 21: QIQI i~l8/ Hl/86 23: 121!!1 BYTE RAW DATA ========== 1 132 13:\ 3 131 133 5 130 132 7 131 131 DAILY AVERAGE VALUES 9 13121 131 11 129 13121 13 129 129 15 129 129 17 128 129 19 129 131 21 130 133 23 131 1.33 25 132 133 27 131 132 29 131ll 131 31 1,30 131 DAILY AVERAGE VALUES 33 131!1 131 35 131ll 131 37 13!21 13{!1 39 130 13{!1 41 130 131 43 131!1 131 45 13QI 132 47 131 133 49 132 133 51 131 132 53 13121 131 55 13J2l 131 DAILY AVERAGE VALUES 57 130 131 59 1 3t21 1. 3!21 61 129 131!1 63 129 13!21 65 129 13(!1 67 129 131 69 13121 131 71 131 133 73 132 134 75 132 134 77 131 132 '79 130 131 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 8.2 8.1 8. ill 8.1 8.1 8. 121 7.9 7.9 7.9 7.8 7.9 8. ill 8.1 8.2 8.1 8. l!i 8.0 8. fll 8.0 8. {ll 8. !!I 8. 121 8.0 8. Ill 8.0 8.1 8.2 8.1 8.0 8. !21 8.0 8. Ill 8. Ql 7.9 7.9 7.9 7.9 8. Ql 8.1 8.2 8.2 CHAN 2 DEG C. ------------ 8.3 8.3 8.2 8.1 8.2 8.1 8. Ql 7.9 7.9 7.9 8.1 8.3 8.3 8.3 8 "') o.L. 8. 1 8.1 8.1 8.1 8. 1 8.0 8. Ill 8.1 8. 1 8.2 8.3 8.3 8.2 8.1 8. 1 8.1 8. 1 8. !Zl 8. i!l 8. 121 8. 1!1 8. 1 8.1 8.3 8.4 8.4 8.2 B. 1 8. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-1!13-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- ~!18 / l 1 /86 l!ll : ~~1121 i~i8 / 11/86 1!13: !21!21 !!18 / 11 / 86 J!l::'"j: !21~1 !218 I 11/86 ~17: fZll!l Y.IB / 11 I 86 !219: i!li!l Y.IS/11/86 11: 0!ll !218/11/86 13:Y.IlZI !218/ 11 /86 15: !!IY.I i!l8/ 1l 186 1 7: f!H!I 1!181 1 1/86 1 9: 1!1!21 !liB/ 11/86 21: '!IY.I ~~18/ 11 /86 23: !ZH!l Ql8 / 12 I 86 !211 : i!l!l! !218/ 12/86 03: 1!1121 i218/ 12/86 !215: IZI!ZI 1218/ l2/86 1217: !210 t::JS/ 12/86 1219: !21~1 QIB/12/86 11:rlH2J !218/ 12/86 13: !ll0 ~2181 12/86 15: 1!1121 !?.18/12186 17:i!H!I 1218/ i 2/86 19: fil0 1!!8/ 12/86 21: QIY.I Ql8/ 12/86 23:00 11.18/13/86 !i.l1: !21!21 !218/ 13186 1213: !21!.!1 f218/ 13186 05: 0QI !!18/ 13/86 !217: 00 1218/ 13/86 !219: Y..H21 i218/1 3 I 86 11 : 00 1218/ 13 I 86 1. 3 : QIQI 1218/13/86 15:!!11!1 '-'18/13/86 17:!!11!1 !218/13/86 19:uH21 i!IB/1.:::.\/86 21 :i2HZI 1218/ 1::::;/86 23: IZIY.S BYTE RAW DATA ==== ========== 81 1 3121 1 ::.>t 83 129 131!1 85 129 129 87 129 129 89 128 129 91 128 129 93 129 130 95 129 130 97 13121 131 99 129 13~1 1Y.I1 128 129 103 127 127 DAILY AVERAGE VALUES 105 127 127 lel7 127 127 109 127 128 111 127 128 113 127 128 115 127 128 117 128 129 119 128 130 121 129 131 123 129 130 125 129 129 127 128 128 DAILY AVERAGE VALUES 129 127 127 131 126 126 133 135 137 139 141 143 125 125 124 123 122 121 122 121 122 122 122 122 145 122 12:2 147 122 122 149 121 121 151 121 121 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 8. Ill 7.9 7.9 7.9 7.8 7.8 7.9 7.9 8. !21 7.9 7.8 7.7 7.9 7.7 7 .. 7 7.7 7.7 7.7 7.7 7.8 7.8 7.9 7.9 7.9 7.8 7.8 7.7 7.6 7.5 7.4 7.2 7.2 7.2 7.2 7.2 7.2 7.1 7. 1 7.3 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 8.1 8. f2l 7.9 '7. 9 7.9 7.9 8. f21 8. f2i 8.1 8.0 7.9 7.7 8. '~ 7.7 7.7 7.8 7.8 7.8 7.8 7.9 8. es 8.1 8. 12i 7.9 7.8 7. (i 7.7 7.6 7.5 7.3 7.1 7. 1 "'7 ..., I o .t... 7.2 7.2 7.2 7.1 7. 1 7.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 3 12-03-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TII"IE ------·--------------------- i~i8/14/86 1211:0!!! iZI8/ 14/86 !!13: i!IJ!l !i.lS/14/86 1215: !1.10 1218/14/86 ~217:!.!1121 !liS/ 1 4/86 £19: t!ifl1 QIS/14/86 11:f2l0 £18/14/86 13:0121 !!18114/86 15:1mz1 !Zi8/l4/86 17:0l1J i~IB / 1 4/86 1 9: 121!.!1 iZI8/ 14/86 21: Ql!i.l !!18/1.4/86 23:!!1!.!1 l!l8/ 15/86 !211: !ZIQI 1.!18/ 15/86 1!13: 1210 !218/15/86 1215:0121 ~:18 I 15/86 !!17: illiZI Y.i8/ 15/86 09: 1211!1 !:'!18 / 1 5/ 86 11 : 00 !216/ 15/86 13: IlliZI V-18/15/86 15:0!21 1118/1 5/86 1 7 : QlfZI 1!18/15/86 19:!llf{.l !218/15/86 21:1!1~1 i!l8/15/86 2:~: !210 Q18/ 16/86 1211: !ZI0 !218/1.6/86 J!l3: !ZII!I i2l8/ 16/86 05:1210 1218/16/86 07: flll21 !218/16/86 1219: ll10 !218 / 16/86 11 : f211il !218/ 16/86 13: 11.1!!.1 ~~18/ 16/86 15: IZI!ZI ~!18/16/86 17:!ZIV.I !218/16/86 19:12l!ll 12iB/ 16/86 21: lllf!l i!.l8/ 16/86 23: illiZI BYTE 153 155 157 RAW DATA ========== 121 121 121 121 12l. 120 159 12Ql 121 161 121 121 163 122 123 165 123 124 167 124 125 169 125 126 171 125 126 173 125 126 175 125 126 DAILY AVERAGE VALUES 177 179 181 183 125 125 125 124 126 125 125 125 185 124 125 187 124 125 189 125 126 191 125 127 193 126 128 195 126 128 197 126 127 199 125 126 DAILY AVEF:AGE 201. 125 125 2t!l3 125 125 21215 124 124 2!!17 123 124 2f2J9 123 124 211 124 125 213 126 128 215 128 130 217 129 131Zl 219 128 129 221 126 126 223 124 124 VALUES DAILY AVERA~E VALUES CHAN 1 DEG C. ------------ 7. 1 7. 1 7. 1 7. !Zl 7. 1 7.2 7.3 7.4 7.5 7.5 7.5 7.5 7.3 7.5 7.5 7.5 7.4 7.4 7.4 7.5 7.5 7.6 7.6 7.6 7.5 7.5 7.5 7.5 7.4 7.3 7.3 7.4 7.6 7.8 7.9 7.8 7.6 7.4 -c: I • ...J DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 7. 1 7. 1 7. QS 7. 1 7. 1 7.3 7.4 7.5 7.6 7.6 7.6 7.6 7.3 7.6 7.5 7.5 7.5 7.5 7.5 7.6 7.7 7.8 7.8 7.7 7.6 7.6 7.5 7.5 7.4 7.4 7.4 7.5 7.8 8. !2! 8.0 7.9 7.6 7.4 7.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-03-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TII"lE ----------------===== !218/ 17/86 1211:1210 !218/ 1 ':? /86 1!13: ~!IQI 1!18/1 7/86 1215: j!l!Zi !218/ 17/86 !217: !ZIQi 1<!18/ 17/86 !219: Jr!H21 !!18/ 17/86 11: j00 Q/8/17/86 13:Y.lf?.l !218/17/86 15:i!lt21 1218/17/86 17:00 Ql8/ 17/86 19: QlfZI 11.18/17/86 21:1210 !2!8/ 1 7/86 23: f!IJI:I iZiB/18/86 IZH:\!1!?1 1218/18/86 03: 12111.1 1218/18/86 1!15: 121121 !Zl8 I 18/86 li.i7: 0!Zi 1!18/18/86 09: 1211!! IZI8/18/86 11: 00 Ql8/18/86 13: Y.IQI 08/18/86 15!00 !218/18/86 17: !Zif2l !218/ 18/86 19: !2Ho !218/ 18/86 21 : i!l!ZI ~18/18./86 23:121121 08/19/86 01:0121 1218/19/86 !213: t!l!Z! 1218/19/86 05:9.10 ;218 / 1 9 /86 07: !21!21 !218/19/86 !219:0!21 P-18/19/86 11:1!1121 !218 / 1 9 I 86 1 3: 1!10 !!iS/ 19/86 15: !ZIIZI !218/ 1 9 / 86 1 7: !21~l !(.18/ 19/86 19: 12!12! Y.l8/ 19/86 21: ~~1!2i 1::18 / l'=t / 86 23: ~!H?.I BYTE RAW DATA ==== ========== 225 123 121 227 121 12121 229 120 119 231 119 118 233 119 119 235 12!21 122 237 124 126 239 126 129 241 128 131 243 129 131!1 245 128 129 247 127 127 DAILY AVERAGE VALUES 249 126 126 251 125 126 253 125 125 255 125 126. 257 126 127 259 127 128 261 127 128 263 128 129 265 129 13121 267 128 130 269 129 131!! 271 128 129 DAILY AVERAGE VALUES 273 128 128 275 127 128 277 127 128 279 127 128 281 127 128 283 127 129 285 129 132 287 131 134 289 131 134 291 131 133 293 130 131 295 13!21 131 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.1 7. V.l 6.9 6.9 7.121 7.4 7.6 7.8 7.9 7.8 7.7 7 .. 4 7.6 7.5 7.5 7.5 7.6 7.7 7.7 7.8 7.9 7.8 7.9 7.8 7.7 7.8 7.7 7.7 7.7 7.7 7.7 7.9 8.1 8.1 8.1 8. !Zl 8. Ql 7,9 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 7.1 7. f21 6.9 6.8 6.9 7.2 7.6 7.9 8.1 8. ~!I 7.9 7.7 7.4 7.6 7.6 7.5 7.6 7.7 7.8 7.8 7.9 8. 1!1 8. !21 e. tZI 7.9 7.8 7.8 7.8 7.8 7.8 7.8 7.9 8.2 8.4 8.4 8.3 8.1 8. 1 8. IZI ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-J213-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TII"1E ~·-------------------------- !218/ 2!!1 /86 ~~ 1 : !Zik!l iZlB/2~!1/86 1!13: f!IQ! QIS I 2Ql/ 86 1.!15: !21121 !!18/2!!1/86 1217: !llQI 1218/2~1/86 1!.19: 00 i!l8 I 2Qi I 86 11 : 1£1!21 i218 I 2it.l /86 13: !21121 Ql8/2QS/86 15: QIIZI fii8/2lll/86 17:00 !38/2!21/86 19: !ZIY.i ~:l8/2W.1186 21: ~H!l i2l8/2fll186 23: !lll!i 1!18/21/86 1!11:01!1 !ZIB/21 /86 Ql3: 00 !218/21 186 05: 0i21 i218 /21 I 86 1217: l!ll!i Y.IS/21/86 i219:0!!1 1218/21 I 86 11: 1210 !218/21/86 13:!21~1 iZIS / 21 I 86 1 5: 01!1 1218 I 21 I 86 1 7 : 0!21 1218/21/86 19:0121 1218121 I 86 21: IlliZi 1218/21 /86 2~:.: £21~1 1!18/22186 !!11: 1!1!21 !!18/22/86 rll3: !21!!1 Ql8122/86 05: 012> 1218/22186 !Zl7: 0!ll l!iB/22/86 !219: 01i.i !218/22/86 11: f!i!Zi ~~18/22/86 13: 0!21 !~18 I 22 I 86 1 5: i!IY.l !?.!8/ 22/86 17: !ZH!l V.IB/22/86 19: i!h'2i 1!18 /22 I 86 21 : !21!21 !218 /22/86 23: ~IIZl BYTE RAW DATA -------------------- 297 129 13121 299 129 13121 3!.!11 128 129 31!13 127 128 3!215 127 128 31217 128 13121 3~19 13121 134 311 133 137 ::-'13 135 138 315 135 137 317 134 136 319 133 134 DAILY AVERAGE VALUES 321 323 325 327 329 331 333 335 337 13"2 132 131 131 13121 130 129 128 128 128 129 131 133 135 13Qi 134 137 138 339 133 135 341 131 132 343 130 129 DAILY AVERAGE VALUES 345 128 128 347 128 128 349 127 127 351 127 126 353 126 126 355 126 127 357 126 127 359 127 128 361 128 129 363 128 129 365 128 128 367 127 127 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.9 7.9 7.8 7.7 7.7 7.8 8.0 8.3 8.5 8.5 8.4 8.3 8.1 8.2 8.1 8.0 7.9 7.8 7,9 8.1 8.3 8.5 8.3 8. 1 8.10 8.1 7.8 7.8 7.7 7.7 7.6 7.6 7.6 7.7 7.8 7.8 7.8 7.7 7.7 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 8. ~=~ 8. 121 7.9 7.8 7.8 8. Ill 8.4 8.7 8.8 8.7 8.6 8.4 8.3 8 ~-..... 8.1 8. 12! 7.8 7.8 8.0 8.4 8.7 8.8 8.5 8.2 7.9 8.2 7.8 7.8 7.7 7.6 7.6 7.7 7.7 7.8 7.9 7.9 7.8 7.7 7.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-1213-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ----·--·-------------------- i-~18/23/86 %'11: 0£1 !218/23/86 !213: IZSQ! !!18/23/86 1215: l2i!Zi i2l8/23/86 QJ7: !21!:?1 08/23/86 !!19: QIQI 1!18/23/86 11: !21Y.l 1218/23/86 13: 0Y.l Y-18/23/86 15: !21121 1!18/23/86 17 :1.::1k'l 1!18/23/86 19: 1!1!21 1!18/23/86 21: V.l~1 ~2S8/23/86 23: QSQ~ !2!8/24/86 l2l1: IZ!i!l ~!18/24/86 1213: 121!21 1218/24/86 1215: t~l0 !!18/24/86 !217: IZllll !218/24/86 1219: J!i0 1!18/24/86 11:00 1218/24/86 13: 012i 1218/24/86 15: 12ll2l 1218/24/86 17: Y.li!l 1218/24/86 19:00 1218/24/86 21: 121!21 1218/24/86 23: !210 Ql8/25/86 01! l:!ll!l 1218/25/86 !213: IZifll 08/25/86 !215: 1!10 ms/25/86 07: 12s12s 1218/25/86 !219: 0J!I 1218/25/86 11: li%1 08/25/86 13! 01!1 QIS/25/86 15! Y.IY.1 1218/25/86 1 7: Ql!Zi !2i8/2::i/86 19: ,!1!21 I2S8/25/86 21:~1V.'f !218/25/86 23: IZIQI BYTE RAW DATA -------------------- 369 126 126 371 125 125 373 125 124 375 125 125 377 125 126 379 126 127 381 127 128 383 128 129 385 129 13121 387 130 131 389 129 130 391 129 13121 DAILY AVERAGE VALUES 393 129 130 395 129 130 397 129 130 399 129 130 4f211 129 13{21 403 129 l.31 405 131 133 407 133 136 4$219 134 136 411 134 136 413 133 134 415 132 133 DAILY AVERAGE VALUES 41.7 132 133 419 132 132 421 131 131 423 425 427 429 431 433 435 437 131 131 131 131 131 131 132 131 132 132 132 132 132 132 132 131 439 13~!1 131 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.6 7.5 7.5 7.5 7.5 7.6 7.7 7.8 7.9 e. e1 7.9 7.9 7.7 7.9 7.9 7.9 7.9 7.9 7.9 a. 1 8.3 8.4 8.4 8.3 8.2 8.1 8.2 8.2 8.1 8.1 8.1 8. 1 8.1 a. 1 8. 1 8.2 8.1 8. (!I 8.1 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 7.6 7.5 7.4 7.5 7.6 7.7 7.8 7.9 8. !21 8.1 8. 121 8. 1!1 7.8 8. Ill 8. !21 a. 12> 8. !21 a. 121 8.1 8.3 8.6 8.6 8.6 8.4 8.3 8.2 8.3 8.2 8.1 8.2 8.2 8.2 8.2 8.2 6.2 8.2 8.1 8. 1 8.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-03-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE Tit'IE -·------------------------- 1218/26/86 1?.11: 0Ql 1218/26/86 Qi3: !!1!21 ~?18/26/86 Qi5: Y.H!! 1218/26/86 1217: ~il.!l !218/26/86 09:!2}121 !218/26/86 11: 0!!1 1!18/26/86 13: 0(!1 1218/26/86 15:1210 !218/26/86 17: {il0 !!18/26/86 19:00 1218/26/86 21: 01!1 08/26/86 23: lZIJI.I 1~}8 /2 7 /86 1211 : Y.ll!i f!S8/27 /86 IEI3: l!lfll 0El /27 I 86 1215: Qlj(l QlB/27 /86 1217:00 08/27/86 12!9: eses 1!18/27 /86 11 a'.l0 Ql8/27 i86 13: !211.!1 IZ18/27i86 15:1210 1!18/27/86 17: QIQl 1218/27/86 1.9:00 1218/27/86 21: i!ll!l i?.lS/27 /86 23: 0j!l 1218/28/86 1211: ltH!I Y.l8 I 28 I 86 Ql:;.~ : QIQI 1218 I 2 8 I 86 ll15: !lll21 1218/28/86 £17: 121(.!1 1218/28/86 !219: 0!21 i!IS/28/86 11: 1!1121 12!8/28/86 13:1210 QlS/28/86 15: llll!l !!18/28/86 17:0!21 1218/28/86 19: I!H!I i!18 / 28/86 21 : !21121 IZIB/28/86 23: 121!!1 BYTE 441 443 445 447 449 451 453 455 457 459 461 RAW DATA ---·-----------------13$2) 131 130 130 13!21 13121 131 131 132 132 132 131 131 131 131 132 132 132 13~\ 133 132 463 131 131 DAILY AVERAGE VALUES 465 467 469 471 131 131 1 ..,.. ... ) ._,.._ 131 131 130 131 473 13e1 131 475 131 132 477 131 132 479 131 132 481 132 132 483 132 132 485 131 131 487 13i!l 131 DAILY AVERAGE 489 130 131 491 13121 131 493 139.1 131 495 131 131 497 131 131 499 13!21 130 5!-!11 1 3!21 1 30 503 13121 13121 505 131!1 130 51!17 13121 13121 509 130 13!(1 511 1312> 131 VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 8. 121 8. !21 8 .. fZl 8. 121 8. 121 8. 1 8.1 8.2 8.2 8.2 8.2 8.1 8.1 8.1 8.1 8.1 8. Ql 8. Ill B. 1 B. 1 8.1 8.2 8.2 8.1 8. 1!1 8.1 8.0 8. 121 8 .. 0 8.1 8.1 8. 121 8. 121 8. Ill 8. flj 8. 121 8. l!i 8. 121 8. l!l DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 8.1 8.1 8.1 8. 1 8.1 8.2 8.2 8.2 8.3 8.3 8. 1 8.2 8.2 8.2 8. 1 8.1 8.1 8.2 8.2 8.2 8.2 8.2 8.1 8. 1 8.2 8.1 8,1 8.1 8. 1 8.1 8. 1!1 8.0 8. 121 8.0 8. 1!1 8.0 8.1 8.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-Y-13-87 DATA FILE . RIFFLE!!14 . BRADLEY LAI<E HYDRO PROJECT START: QIS/1217 /86 1 7: ~!IQ.l BRADLEY RIVER -RIFFLE REACH STOP: 1121 I !.!11 I 86 12: !lll!l CHAN 1 CHAN ~~ .... DATE TIME BYTE RAW DATA DEG c. DEG c. ======== ---------========== ------====== ----------- Ql(i/29 /86 !211 : ;.~10 513 13i?.l 131 8.0 8.1 1!18/29/86 03: 121!!} 515 131Zl 131 8. l!l 8. 1 ill8/29/86 1!15: 00 517 130 130 8 .1!1 8.0 1?.18/29/86 1!17: rllQl 519 129 13!21 7.9 8. Qi !?.18/29/86 !219: 00 521 129 13121 7.9 8.0 !!18/29 /86 11 : 1210 523 129 131!1 7.9 8.1ZI 08/29/86 13: ~10 525 129 129 7.9 7.9 08/29/86 15: 1!1!21 527 129 129 7.9 7.9 !218/29/86 17:00 529 129 129 7.9 7.9 !!18/29/86 1 9: Y.IIZI 531 129 129 7.9 7.9 1{.18/29/86 2 1 : !!11!1 533 1:29 130 7.9 8.0 (:!18/29/86 23: S2!f21 535 129 129 7.9 7.9 DAILY AVERAGE VALUES 7.9 8. IZI ~18/3!9/86 !211:01!1 537 129 129 7.9 7.9 !218 I 3Ql I 86 £13: 00 539 128 129 7.8 7.9 !218 I 3!!1 I 86 1!15: 00 541 128 129 7.8 7.9 ~!18 I 3~1 I 86 Ql7: 1211!1 543 128 129 7.8 7.9 !218/3!21 I 86 !~I 9 : Y.SI!I 545 128 129 7.8 7.9 !!18/3121/86 11: 0!t.S 547 128 128 7.8 7.8 !!18 / 31!1 I 86 13: 1!1!21 549 128 128 7.8 7.8 !218/3!21/86 15: 1!10 551 128 128 7.8 7.8 IllS I 31!1 I 86 17: 01ZI 553 128 128 7.8 7.8 !218/30/86 19: tZl0 555 128 129 7.8 7.9 !218/3!21/86 21 : l!!i£1 557 128 129 7.8 7.9 !218 I 3lil/ 86 23: !!10 559 128 129 7.8 7.9 DAILY AVERAGE VALUES 7.8 7.9 1!18/31 /86 l!i 1 ! 0!Zi 561 128 128 7.8 7.8 i!IS/31/86 !Zl3: 12lQl 563 128 128 7.8 7.8 !!18/31 /86 f!l5: 01ll 565 128 128 7.8 7.8 08/31/86 1!17 : i!Si!l 567 128 128 7.8 7.8 08/31/86 Ql9: Qlj!J 569 128 128 7. Et 7.8 ~!18/31 /86 11 : !Ml 571 128 128 7.8 7.8 !!S8/31 /86 1 3: Y.l!!l 573 128 128 7.8 /. 8 1!18/31/86 15: l!l!!l 575 1 .. , ...:., ! 128 -... I , I 7.8 i.llB/31 /86 1 7: IilQ) "'::t77 j ~ .. , 1:27 7 .. .,. 7 't:.. / I • ! !,~)8/31/86 1. 9 ~ :.·.:.··· ~:;·?9 12'? l ~~·/ i . ·' . ..,. -·· l " / '-: .. / :::. l / t;; i:~ 2 J :. ;;h,'J ~-~c:~ J .~. ~Z8 1 :~E$ ·:;;.a -r c ...... :i6 /·:~·~: J / ;3~~ ;~:::: ;, f?i(i ~583 126 1 ;·.s 7.8 ·;. 8 ru:::. i L 't 1-i'·)EF<P~GE VALUES 7.8 7.8 t'·rL: f::;r:J.:::t HJWEF\ AUTHOR 1 TY TEt'IF' /STAGE STdD I ES ,, ''' r .:~qe -, J>(,l A R:::PORT FOR DPd'AF'DD IW212 Vb-!iJ. l DEG C TEi'!P/'i t:hr F,EC[J,;,Df:,::, E1FJh/LEV L.:;l<E HYJ.)!:iCI PH.J,JECi BRADLE1 RIVER -RIF~L,~ ni~~~ ). : i~Hl1 1 s .. w k~k; 21 ~ ~~hZ! 23: i!lQI !!19 / !!12 I 86 ill 1 : ~!l!ll !!19/!!12/86 !213: 0!!.1 !2.19/!212/86 1215:!!11!1 Ql9 / 1!12/86 07: 0!!1 (!19/ 1!12/86 !!19: !!lY.I Y.l9 I !!12 /86 11 : IZH!I !?.19/!212/86 13: ~i!ZI !!19 ./02/86 15: !1)1!1 !!19/!!12/86 17: Ql0 ~!19 /1212 I 86 1 9: (!l0 !Zi9/ 1!12/86 21 : IllY./ iZl9/QI2/86 23:1211!1 !219/Qi3l86 1!11: cl0 1!19/1213/B.:S vJ3: flllZI ~l9 ./0:5./86 !215: 0Y.I i2l9/i!IZ.i86 07: ~!Ill 1!19/!213/86 Y-19: !210 !219 /!!13 I 86 l 1 : 0Y.I !!19 /1!13/86 13: !i50 (!19/ !!13/ 86 15: !!ii!l !!19/lZI3/ 86 17: !Mil 1219/ (li3 I 86 1 9 : QIQI !i.l9/i!l3/86 21: !!IQI r!l9/i!13/86 z:::.:!!lf!J :::.: :: ;.;;;; ;::: :. ::.~ :.:~ ::-:;;: ;:::: :::.:, :.:o 7 '>, 1 ~~· 6 1 ) b ;;~~: ;. J. 26 127 C:!!!l~,; 127 127 605 127 127 61Zl7 128 128 DAILY AVERAGE VALUES 6t!l9 128 128 611 127 128 613 127 127 615 127 127 617 127 127 619 127 127 621 127 127 623 128 128 625 128 129 627 128 129 629 128 128 631 128 128 DAILY AVERAGE VALUES 633 128 128 635 128 127 637 127 127 639 127 127 641 127 126 643 126 126 645 126 126 647 127 127 649 127 128 651 127 128 653 128 129 655 129 129 DAILY AVERAGE VALUES f.:::Hr-iri j .UE.G C. f "' • .... o 7.6 7.6 7.6 7.7 7.7 7.8 7.7 7.8 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.7 7.7 7.7 7.6 7.6 7.7 7.7 7.7 7.8 7.9 7.7 DAi 1:1 ;: it.!::. ; F:iFr~';_t:::~)i, CHI:\1'-i 2 t;Ef3 C:. :;;-.; :;:;;::,;:.:..:.;;:.:::::. ;' . / 'I< { I • . J " t.• 7.6 7.5 7.6 7.7 7.7 7.7 7.8 7.7 7.8 7.8 7.7 7.7 7.7 7.7 7.7 7.8 7.9 7.9 7.8 7.8 7.8 7.8 7.7 7.7 7.7 7.6 7.6 7.6 7.7 7.8 7.8 7.9 7.9 7.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page U!l 12-!!13-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T I 1'1E ========== -----·· ----- 1!19/!?.14/86 !!!1: !!1!?.1 1!19/!!14/86 1!13: !211!1 !219 /1214/86 !!15: !21!!! iZI9/l2l4/8t• !217: !!1!21 ~~19 / !214 /86 !!19: 121!!! !!19 I !!14 I 86 1 1 : !!l!Zl ~!19/ i!14 I 86 13: 1210 !ZI91Qi4/86 15:!!1121 !219/1!14/86 17: IZIIZI !!19 I !214 I 86 19: !!1!21 !.219 / 1!14 /86 21 : !ZIY.I !219 I !ZI4 /86 23: !21!!1 !219 /!215186 1!11: !!1121 !219/IZI5/86 1213: !!11!.1 !219/!215/86 !215: 121!21 1!19 I !!15 I 86 !217: 1!.1121 !!19/!215 /86 !219: !ZI!ZI Y.!9 / IZI5 I 86 11 : 121121 IZI9/S!I5/86 13: 01ZI !219/1215/86 15: 0!21 !219/1215186 17:0121 ~191!21!5186 19:1211!.1 !!19/!!15/86 21: Y.IIZI Qi9/IZI5/86 23:00 Y.l9 / !!16 /86 1211 : 1!10 1!191!216/86 !213: !!1!21 Ql9/i!l6186 1215:00 121911!16/86 !217: !21121 !219 I !216 I 86 !219: !!11!1 i!l9/l216 /86 1 1 : l!IIZI i:~19/Ql6/86 13:!!1!;~1 !219 /9.16/86 15: 121!?.1 Ql'=?l/!216/86 17:~10 W-1./916/86 19: I!H!I Ql9 / Ql6 /86 21 : !!1!!1 !!19 / !!16/86 23: Y.H!I BYTE 657 659 661 663 RAW DATA -------------------- 129 129 129 129 128 128 128 128 665 128 128 667 128 128 669 128 128 671 128 129 673 129 129 6 75 13!21 13!21 6 77 1 30 1 311.1 679 129 129 DAILY AVERAGE VALUES 681 128 128 683 127 126 685 126 125 687 125 123 689 124 123 691 124 123 693 124 124 695 125 125 697 126 126 699 127 127 7!!11 127 127 7!213 127 128 DAILY AVERAGE VALUES 7!215 128 128 7fi..l7 128 128 7~'19 128 128 711 128 128 713 127 127 715 128 128 717 128 128 719 129 129 721 13!21 13121 723 131ZI 13!21 725 129 131!1 727 129 129 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.9 7.9 7.8 7.8 7.8 7.8 7.8 7.8 7.9 8. !21 8.0 7.9 7.9 7.8 7.7 7.6 7.5 7.4 7.4 7.4 7.5 7.6 7.7 7.7 7.7 7.6 7.8 7.8 7.8 7.8 7.7 7.8 7.8 7.9 8.0 8. 121 7.9 7.9 7.9 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 7.9 7.9 7.8 7.8 7.8 7.8 7.8 7.9 7.9 8. 121 8. !!I 7.9 7.9 7.8 7.6 7.5 7.3 7.3 7.3 7.4 7.5 7.6 7.7 7.7 7.8 7.5 7.8 7.8 7.8 7.8 7.7 7.8 7.8 7.9 8. Ql 8.0 8. I!! 7.9 7.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-1!!3-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- m9 l el7 186 01 : ,:zsrz1 Ql9/!Zl7/86 !ZI3:~H!l 12!9 / ~::17 /86 1215: 0f?l !!1'11 / !2!7 /86 !217: IlliZI ~19 /!ZI7 /86 t!l9: 1211~1 !219/!217/86 11:!~QI 09/07/86 13: !210 !219/!!.17/86 15:0121 !!19/1!17/86 17:12!1!1 1219 /f2S7 /86 19: 0121 !:~19/!!17 /86 21:0121 !ZI9 ./ Ql7 /86 23: IZI~I i!l9 I 1!!8 /86 1211 : i!H!I IZI9/Ql8/86 12!3: 00 fB9 I f!f8 I 86 !!15: Y.hll 12!9 /~~18/86 07:00 !219/1!18/86 !2'19: IZH?.! (!19/1!!8186 11:0~21 !.il9 /!218/86 13: !!1121 f!!9/IZI8/86 15:f!H2S !219 I !2i8 / 86 1 7 : !210 QI9./Qf8/86 19:121!!1 ~19 /i!!B/86 21: 00 Ql9 /12!8/86 23:00 QI9/Y.l9/86 !!.11:1!1!21 !219 I !ZI9/86 Ul3: J:':IQ! 1Zf9 I l2i9 /86 12S5: 1211!1 !!19 I !'219/86 !2S7: IlliZI !219 I !ZS9 /86 ~<:19: f210 Q19 /i-!19/86 1 :1.: V.l0 1!19 I l2!9 I 86 13: IZ!ti.l Y.l9/Y.I9/86 15: !21121 !!.19 /09/86 17: 1210 f?.l9 I Q!9 /86 1 9: fZH!I ~219d219/86 21:1!10 i2!9/i2l9 /86 : f!H!I BYTE RAW DATA -------------------- 729 129 129 731 128 128 733 128 128 735 128 128 737 128 127 739 128 127 741 128 128 743 128 128 745 128 128 747 128 128 749 128 128 751 128 128 DAILY AVERAGE VALUES 753 128 127 755 128 127 757 128 127 759 127 127 761 127 126 763 126 126 765 127 126 767 126 125 769 126 125 771 125 125 773 125 124 775 125 124 DAILY AVERAGE VALUES 777 124 123 779 124 122 781 123 121 783 123 121 785 122 120 787 121 12~1 789 121 12~1 791 121 121 793 122 121 795 122 121 797 122 121 799 122 12121 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.9 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.7 7.7 7.6 7.7 7.6 7.6 7.5 7.5 7.5 7.7 7.4 7.4 7.3 7.3 7.2 7.1 7.1 7.1 7.2 7.2 7.2 7.2 7.2 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 7.9 7.8 7.8 7.8 7.7 I • l 7.8 7.8 7.8 7.8 7.8 7.8 7.8 7.7 7.7 7.7 7.7 7.6 7.6 7.6 7.5 7.5 7.5 7.4 7.4 7.6 7.3 7.2 7.1 7.1 7. Ill 7. I!~ 7.0 7.1 7.1 7. 1 7. 1 7. Y.i 7.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 12 12-J!I3-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE ·---------------- TIME ===== J!l9 / 1!!1 I 86 ~~ 1 : J2!1ZI !Zi9/ H:l/86 1213:121121 12l9/1til/86 1!15: 1210 1219 I 11!1 I 8 6 1217 : !21121 1!19 /HI I 86 !219: 00 l-~>9 I Hl/86 11: !21!21 1!19/ 10/86 13:00 IZ19/1QI I 86 15: L.ill!i !219 / 1!!1186 17: 00 !219/ 1!21/86 19: 00 !219/10/86 21:J!I0 1!19 I 1 Y.l I 86 23 : rli!21 Qi9 /11 / 86 1!11 : l..il!ll 09/11/86 !!13:00 1!19/11/86 V.l5: 00 ~~1'-r / 1 1/86 1217: 00 i219 / 11/86 !219: IZI!ZI 1219/ 11 /86 11: 1210 !2!9 I 11 l 86 13: 0121 Ql9/11/86 15:00 !219 I 11/86 17: QI!ZI kl9 / 11/86 1 9: Q)0 1219/ 11 / 86 21 : Y.ll!l !99/11/86 23: 0~1 1219/ 12/86 IZI1 : !ll!ll 1!19 / 12 I 86 !213: fll0 !!19/12/86 $215: 00 1!19 / 12 I 86 1!17: 0f!l !219/ 12/86 !!19: t!H-3 !!19/12/86 11: !211!1 Ql9/12/86 13:0121 al9 I 1 2 / 86 1 5: 1!10 12)9/12/86 17: 0121 i219 I 12/86 19: l!lf!l 1::!9 /12/86 21: 1!.1!21 !219/12/86 23:l21121 BYTE RAW DATA ========== 81211 121 119 8fll3 120 118 8t:l5 11 9 11 7 81!17 11 9 11 7 81219 11 8 11 6 811 118 117 813 119 118 815 12121 120 817 121 121 819 122 121 821 122 121 823 121 121 DAILY AVERAGE 825 121 119 827 120 119 829 119 118 831 119 117 833 119 117 835 119 118 837 119 119 839 121 120 841 121 121 843 122 122 845 122 121 847 122 121 DAILY AVERAGE 849 121 120 851 121 119 853 12Y.I 118 855 119 117 857 118 116 859 118 117 861 119 11.8 863 12121 121 865 122 122 867 123 123 869 123 122 871 122 121 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== 7.1 7. Ill 6.9 6.9 6.8 6.8 6.9 7.0 7.1 7.2 7.2 7.1 7.0 7.1 7.0 6.9 6.9 . 6.9 6.9 6.9 7.1 7. 1 7.2 7.2 7.2 7 • QS 7.1 7.1 7.0 6.9 6.8 6.8 6.9 7. 12! 7.2 7.3 7.3 7.2 7. 1 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 6.9 6.8 6.7 6.7 6.6 6.7 6.8 7. i!l 7.1 7.1 7.1 7.1 6.9 6.9 6.9 6.8 6.7 6.7 6.8 6.9 7.0 7.1 7.2 7. 1 7.1 6.9 7.0 6.9 6.8 6.7 6.6 6.7 6.8 7. 1 7.2 7.3 7.2 7. 1 6.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page t::; 12-Y.l3-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- !?.19 /1 ~)/86 Y.l 1: !210 Ql9/13/86 !213:0Y.l !219 I 13/86 1215: 0f2l Y-.19/13/86 l!l7:0i21 1219/13/86 Qi9:f2J0 ~;19 I 13/86 11: 0121 Ql9 / 13/86 13: 121121 V.19 I 13186 15: l!IY.I Y-19/13/86 17:fZ@ 1219 I 13/86 19: Ql£1 lZi9/13/86 21:00 ~.::19/13/86 23:12112! BYTE RAW DATA ========== 873 121 12!21 875 121 119 877 121 120 879 121 119 881 120 119 883 12!!1 118 885 120 119 887 121 12!21 889 121 121 891 122 122 893 122 121 895 122 121 DAILY AVERAGE VALUES 1!19 I 14/86 Qll :!!1121 !2!9/14/86 1213:0!21 Y.l9/ 14/86 !215: 121!21 !219 /14/86 1217: 121121 09 I 14/86 !219: 0!21 Y.l9/ 14/86 11:00 !219/14/86 13a10 J!J9/14/86 15:00 !!19/14186 17:!210 !219 I 1 4/86 1 9 : 00 !219/14186 21: Y.lY.I Y..19 I 14/86 23:1210 fZI9/15/86 01: 0!21 !!19 I 1 5/86 !213: 121121 091i5/86 !!15:00 !219 I 15/86 07: !2l!ZI 1219/15/86 09:f1.10 1!19 I 15/86 11: !MI il19/15/86 13:!2lY.I !219 / 15/86 15: V.llll Ql9 / 15/86 17: !21121 !!19 /15/86 19: I!IQI !219 / 15/86 21 : 1!1!!1 Ql9./ 15/86 23: !21J!l 897 121 12121 899 121 119 9lil1 12f2l 11 8 903 119 117 905 119 117 91217 11 9 116 91!19 11 9 1 18 911 120 12121 913 122 122 915 123 124 917 125 125 91.9 126 126 DAILY AVERAGE 921 125 125 923 125 125 925 125 125 927 125 125 929 125 124 931 125 125 933 125 125 935 126 126 937 126 127 939 127 127 941 128 128 943 128 128 DAILY AVERAGE VALUES VALUES CHAN 1 DEG C. ====== 7.1 7. 1 7.1 7.1 7.0 7. 121 7. Ql 7. 1 7.1 7.2 7.2 7.2 7.1 7.1 7.1 7. f!j 6.9 6.9 6.9 6.9 7.0 7.2 7.3 7.5 7.6 7.1 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.6 7.6 7.7 7.8 7.8 7.6 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10101/86 12:00 CHAN 2 DEG C. ------------ 7. 1.(1 6.9 7. 121 6.9 6.9 6.8 6.9 7. Y.l 7. 1 7.2 7.1 7. 1 7.0 7. 1"21 6.9 6.8 6.7 6.7 6.6 6.8 7.0 7.2 7.4 7.5 7.6 7. Ql 7.5 7.5 7.5 7.5 7.4 7.5 7.5 7.6 7.7 7.7 7.8 7.8 7.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 14 12-1213-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE ·---------------- TIME ===== Y.l9 / 16/86 Ill!: 00 09/16186 1213:0121 ~~19/16186 ~215:0~! 1219/ 16 I 86 1217: 121121 Y-19/16/86 1219: 00 1!19 I 16186 11: ~H21 1!19/ 16/86 13: 0f21 1219/16/86 15:0121 1219 I 1 6 I 86 1 7 : 1!10 1{19/16186 19:1210 1219 I 1 6/ 86 21 : 1210 !219/16186 23:!21121 t!l9/1 7 I 86 l!ll : !Z!IZI {!19 /17/86 1213: ~10 1!19 I 17186 05: !lll!> 1!19 /17186 1217: 1210 !!19 / 1 7 I 86 J!l9 : !lil!l 1219 /1 7 I 86 11 : 01!1 09117186 13:k:ll2! 1219/ 1 7 I 86 15: 00 Ql9 /1 7 I 86 1 7 : !!liZ! Ql9/ 17/86 19:00 1219 I 17186 21: !!H21 1219117/86 2:::::: i2H3 1219 I 18/86 IZll : S;:lt/.1 f!l91 18/86 1213: f,1Q! 1!191 18/86 05:00 rt.l91 18186 1!17: v.uo 1219 I 18186 !ll9: J:!IIZl r?.f9 I 18/86 11: 121121 IZS9 I 1 8 I 86 1 3: 0!21 i!l91 18186 15: I!Hil ~!19/181 86 1 7: 12!1!1 1'2'191 18186 19: l!lel !J.i9/18/86 21:!2H!i i2i9118/86 23:Y.II!l BYTE RAW DATA -.. ------------------- 945 127 127 947 127 127 949 127 126 951 127 126 953 127 126 955 127 127 957 127 127 959 127 127 961 128 127 963 128 128 965 128 128 967 128 127 DAILY AVERAGE VALUES 969 127 126 971 127 126 973 127 127 975 127 127 977 127 127 979 127 127 981 128 127 983 128 127 985 128 127 987 128 127 989 128 127 991 127 126 DAILY AVERAGE VALUES 993 126 125 995 126 125 997 125 124 999 125 123 101211 125 123 10!2l3 124 123 11211215 125 124 1!!107 125 125 10!219 126 125 1 €111 126 126 1013 126 126 11!115 126 125 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.8 7.8 7.8 7.8 7.8 7.7 7.7 7.6 7.6 7.5 7.5 7.5 7.4 7.5 7.5 7.6 7.6 7.6 7.6 7.5 DATA FILE : RIFFLE04 START: 08107186 17:00 STOP: 10101/86 12:00 CHAN 2 DEG C. ------------ 7.7 7.7 7.6 7.6 7.6 7.7 7.7 7.7 7.7 7.8 7.8 7.7 7.7 7.6 7.6 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.7 7.6 7.7 7.5 7.5 7.4 7.3 7.3 7.3 7.4 7.5 7.5 7.6 7.6 7.5 7.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-1!13-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- ~!19 I 1 9 I 86 ~ll1 : 00 !219 I 19 I 86 !213: l!l!ZI 1!19 I 1 9/86 ll15! !21121 1219 I 1 9 I 86 !217: 1210 !.":>9/19186 09:00 ~!19119/86 11:00 1219/1. 9 I 86 13: 0121 1!19/ 19/86 15: 0!21 !219 /1 9 I 86 1 7: 00 !!19 I 19/86 19: 1!1!21 f2i9 / 19/86 21: 0(!1 1!19/19 /86 23: 0121 !2!9 I 2!!1 I 86 lll1 : !!1!2! !?.1912Lil/86 03: 0!21 i219 I 2121 I 86 1!15: !!Hll 1!1912121/86 07:00 1219 I 2~!1 I 86 09: 0!21 1219 I 212! I 86 11 :l!l0 09 I 2121 I 86 13: !ZI0 !219/20186 15:00 !219 12!21186 17:00 !219/2!21/86 19:0121 !21912121/86 21:00 i219 120/86 23:00 1219/21/86 !211: 121!21 1!!9/21 /86 !2!3: !210 !219/21/86 05:00 1!19121/86 07:00 1219/21 I 86 !ll9: !210 1219/21/86 11: !211!1 ~19 /21 /86 13! 1210 1!19 /2 1 I 86 1 5: 0!21 !!19 I 21 I 86 1 7: 01!1 1!19/21/86 19:00 !219 I 21 /86 21: 1Zll21 1219/21/86 23:1!HZI BYTE RAW DATA -------------------- l!Zl1 7 126 125 11!119 125 124 H121 125 124 1023 125 124 112125 125 124 1027 125 124 1029 125 124 1031 125 124 1033 125 125 1035 125 125 112137 126 125 1039 126 125 DAILY AVERAGE 1041 126 125 1043 126 126 1!2145 126 126 1047 126 125 1049 126 125 1051 126 125 1053 126 126 U:S55 127 127 112157 127 127 1059 128 127 1!2161 127 127 112163 127 126 DAILY AVERAGE 1Y.l65 126 125 112167 126 124 1069 125 124 1071 125 124 1073 125 123 Hl75 125 123 1077 124 123 1079 125 124 1081 125 124 1~!183 125 125 112185 126 126 H!187 126 125 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ------------ 7.6 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.6 7.6 7.5 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.7 7.7 7.8 7.7 7.7 7.6 7.6 7.6 7.5 7.5 7.5 7.5 7.4 7.5 7.5 7.5 7.6 7.6 7.5 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 7.5 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.5 7.5 7.5 7.5 7.4 7.5 7.6 7.6 7.5 7.5 7.5 7.6 7.7 7.7 7.7 7.7 7.6 7.6 7.5 7.4 7.4 7.4 7.3 7.3 .... -I •.:;. 7.4 7.4 7.5 7.6 7.5 7.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-03-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- f!l9/22/86 fll:00 !2!9/22/86 i!13:~112.1 IZI9/22/86 t:!l5: ti.l0 09/22/86 f!l7: IZIJZI fll9 / 22/86 1!19: rllf!l 09/22/86 11: IlliZI !219/22/86 13: 0!tJ !219/22/86 15:121121 ~19/22/86 17:1210 1!)9/22/86 19:0121 1!19/22/86 21:00 1219/22/86 23: 1!10 ~!)9/23/86 01:00 09/23/86 03:00 !ll9 I 23 I 86 !liS: 01ll 09/23/86 07: Y.l0 09/23/86 !219:1Zil!1 ~!19/23/86 11:!2Ho 1219/23/86 13:1!1J£1 09/23/86 15:12H21 1!19/23/86 17: lilfll 11.19/23/86 19: 1210 1!19/23/86 21:4210 !!19/23/86 23! 0121 09/24/86 Ql1: 01, 09/24/86 !213: f£1121 !219/24/86 l2l5: fll0 ~<:19/24/86 1!17: !21!21 1219/24/86 1219:00 1219/24/86 11:0!21 1219/24/86 13:00 1219 I 24/86 15: 1!1!21 1219/24/86 17:00 1!19/24/86 19: 1211!1 lll9/24/86 21: (.00 1219/24/86 23: !!IIZI BYTE RAW DATA ========== 11!189 126 125 !Y-19 1 125 1 25 H~l93 125 124 112195 125 123 1!2197 125 123 112199 125 123 111211 125 123 1llll3 125 123 1105 125 123 1107 124 122 111!19 123 121 1111 122 120 DAILY AVERAGE VALUES 1113 121 119 1115 121 118 1117 120 117 1119 119 117 1121 118 116 1123 117 115 1125 117 115 1127 118 116 1129 118 116 1131 118 115 1133 117 115 1135 116 114 DAILY AVERAGE VALUES 1137 115 112 1139 114 112 1141 114 111 1143 113 111 1145 112 110 1147 112 11121 1149 113 111 1151 114 112 1153 115 113 1155 116 114 1157 115 113 1159 114 112 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.6 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.4 7.3 7.2 7.5 7.1 7.1 7 m flJ 6.9 6.8 6.7 6.7 6.8 6.8 6.8 6.7 6.6 6.8 6.5 6.4 6.4 6.3 6.2 6.2 6.3 6.4 6.5 6.6 6.5 6.4 6.4 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 7.5 7.5 7.4 7.3 7.3 7.3 7.3 7.3 7.3 7.2 7.1 7. ~~ 7.3 6.9 6.8 6.7 6.7 6.6 6.5 6.5 6.6 6.6 6.5 6.5 6.4 6.6 6.2 6.2 6.1 6.1 6.0 6.0 6.1 6.2 6.3 6.4 6.3 6.2 6.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-03-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ======== ---------- !!19/25/86 1211:00 ~19/25/86 IZI3:0f21 09/25/86 J!l5: 0121 1219/25/86 07: QJ0 !219 / 25 I 8 6 Ji.!9: 00 {219 /25/86 11: 00 09/25/86 13:00 C!f9/25/86 15:~Jf21 09/25/86 17:00 09/25/86 19: fZl!ll V-19/25/86 21: 1!10 l!l9/25/86 23: 1!1121 1219/26/86 1!11:00 1219/26/86 1213:00 !ZI9 I 26/86 !ZI5: t!i0 09/26/86 07:11>0 !!19/26/86 J!I9:!Zif21 09/26/86 11:00 1219/26/86 13: Y.l0 ~?.19/26/86 15:00 ~!19/26/86 17:~10 09/26/86 19:f!l0 1219/26/86 21: 1!1!21 ~!19 /26/86 23: 0!lf 09/27/86 01:00 !219/27/86 !ll3:!210 09/27/86 05:00 Ql9 I 27 I 86 1!17: l21f21 1219127186 1219:00 i219/27/86 11:l!lf21 09/27186 13:00 Q19 I 2 7 /86 1 5 : 1210 1219/27/86 17:!210 !!19/27/86 19:QIIll !219 /27/86 21: 0121 1219/27/86 23: 1!1121 BYTE RAW DATA ========== 1161 114 112 1163 113 111 1165 112 1 HI 116 7 11 2 1 1!19 1169 111 leiS 11 71 111 11ZI8 1173 111 11218 1175 111 109 1177 112 110 1179 112 110 1181 111 109 1183 111 108 DAILY AVERAGE VALUES 1185 11!.!1 108 1187 110 107 1189 109 1f217 1191 109 106 1193 11219 106 1195 lltJ9 107 11 97 110 11218 11 99 11121 109 1201 111 11121 1203 112 110 121215 112 111 121217 113 112 DAILY AVERAGE VALUES 1209 112 112 1211 112 111 1213 112 111 1215 112 111 1217 112 111 1219 113 112 1221 114 112 1223 114 113 1225 115 114 1227 116 115 1229 116 115 1231 116 115 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.4 6.3 6.2 6.2 6.1 6.1 6.1 6.1 6.2 6.2 6.1 6.1 6.2 6.121 6.0 5.9 5.9 5.9 5.9 6. Ill 6.0 6.1 6.2 6.2 6.3 6.0 6.2 6.2 6.2 6.2 6.2 6.3 6.4 6.4 6.5 6.6 6.6 6.6 6.4 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 6.2 6. 1 6.0 5.9 5.8 5.8 5.8 5.9 6.0 6. 1!1 5.9 5.8 5.9 5.8 5.7 5.7 5.6 5.6 5.7 5.8 5.9 6. 1!1 6.0 6.1 6.2 5.8 6.2 6.1 6.1 6.1 6.1 6.2 6.2 6.3 6.4 6.5 6.5 6.5 6.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 18 12-1213-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -------------------------- !!19/28/86 01: i2ll2l i1.l9 /28/86 1213: !!IQI 1!19 / 28 I 86 05: i2l0 !219/28/86 !ZI7:01!l Ql9/28/86 1!19: 01!1 i!l9 /28/86 11:00 09/28/86 13:00 !219/28/86 15:1!1!21 1219/28/86 17:00 !219/28/86 19:00 !219/28/86 21:00 1!.19 /28/86 23: f.!IIZ! 09/29/86 l!il.:00 1!19 I 29 I 86 1!13: IZHZI 1!19 /29 I 86 1215: 0e1 1219/29/86 1217:1210 09/29/86 e19: 01!1 1!19 /29/86 11: 0121 !39/29/86 13:~!lfll }219/29/86 15:00 i219 /29/86 17: 00 1219/29/86 19:00 1~9 /29/86 21: 0!21 1219/29/86 23:00 1!19 I 31ZS I 86 1!11 : 121121 (!19/3!!1/86 !213: 1210 !!19/3!2! I 86 05: 0i!l 09 I 31!1/86 Y.I7: 0121 09 I 3121/86 1219: fll0 !!19 I 31!1/86 1 1 : 121121 09/30/86 13:1!1!!1 1219 I 30 I 86 1 5: !Zl!2i (~19 I 3!!1 I 86 1 7: 01Zl QI9/3!ZI/86 19:1!1121 1!19 I 3lll /86 21 : 01ll !!19/31!1i86 23: 1!1!21 BYTE RAW DATA ·-------------------- 1233 116 114 1235 115 114 1237 115 114 1239 115 114 1241 115 113 1243 115 114 1245 116 114 1247 116 116 1249 118 117 1251 118 118 1253 119 118 1255 119 118 DAILY AVERAGE VALUES 1257 119 118 1259 119 118 1261 118 117 1263 118 117 1265 118 116 1267 118 116 1269 118 117 1271 119 119 1273 12JZI 120 1275 121 121 1277 121 120 1279 121 120 DAILY AVERAGE VALUES 1281 121!1 119 1283 120 119 1285 12~1 11 9 1287 120 118 1289 119 118 1291 119 117 1293 119 117 1295 119 118 1297 120 119 1299 120 119 1301 120 119 131!13 121ll 1 18 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.6 6.5 6.5 6.5 6.5 6.5 6.6 6.6 6.8 6.8 6.9 6.9 6.6 6.9 6.9 6.8 6.8 6.8 6.8 6.9 6.9 7.0 7.1 7. 1 7.1" 6.9 7.0 7.0 7.0 7.0 6.9 6.9 6.9 6.9 7 .1!1 7. !21 7.0 7.0 7.0 DATA FILE : RIFFLE04 START: 08107/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 6.4 6.4 6.4 6.4 6.3 6.4 6.4 6.6 6.7 6.8 6.8 6.8 6.5 6.8 6.8 6.7 6.7 6.6 6.6 6.7 6.9 7.0 7. 1 7. ill 7.0 6.9 6.9 6.9 6.9 6.8 6.9 6.7 6.7 6.8 6.9 6.9 6.9 6.8 6.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 19 12-1213-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME BYTE RAW DATA -----------------========== ------------- Ul/01/86 1:? 1 : 121!2! 131.!15 12!21 118 H?/01 /86 1!13: f.!I!ZI 1307 119 118 li21/Y.l1 /86 ~15: 00 1309 119 117 lr!l I 1211 I 86 es7: 121121 1311 119 117 H3/01/86 !{.19: !Zl0 1313 119 117 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.0 6.9 6.9 6.9 6.9 6.9 DATA FILE : RIFFLE04 START: 08/07/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 6.8 6.8 6.7 6.7 6.7 6.7 ' .. ' ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-2'7l-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATA FILE ; RIFFLE05 START: 10/01186 13:00 STOP: 11/19/86 11:45 BEGIN OBS :CHAN1=6.9 CHAN2=6.7 0 ERRORS USED=1315 TIME=11:33 END OBS :CHAN 1=4.6 CHAN 2=4.2 0 ERRORS UESD=1177 LOW BAT DATE TIME ::.::======= ===== 1.0i!:'ll 186 1~$: J!10 1 l!i/£!11 i86 15: 0!!1 1121/11.11/86 17:1211!1 1 Ql I 1!1 1 /86 19: IM!I li!l/ 01 I 86 2 1 : 0121 HUto1 186 23::00 Hll!!12/86 !!11: 0f!~ 1 Ql/02/86 ~13: 121~3 1!21 I !!12/86 1!15: 00 ll?l/1212/86 ~!17: 00 1125/IZ12186 09: fMI l!Zl/QI2/86 11!0!ll HI /1212/86 1 ::.>: 121121 1 Ql/!212/86 15:00 10/1!12/86 17: f...i1121 lQ)/ 1!12 /86 1 9: 0Y.i 11!1 /1212 I 8¢> 21 : QIQJ Hil02186 23: Y.l0 1!!1/03186 ('11:J!JJ!I 1 Ql/03/86 !213: l!i!!l li!l/11.1~5/86 fZI5: 01!1 Hi/ 1!13/86 !!17: 121121 Hl/03186 09: 01?.1 lfli/1~13/86 11:00 llll/03/86 l.3: Ul0 l.l?f I 1213/86 15: 0!21 HI I !1.1~5 I 86 17: 0121 Hl/1213;;96 19: euo 1121 I ~53/ 86 21 : !21!!! 11!1/!?13/86 2:::.:;: !!IY.I BYTE RAW DATA ========== 1 119 117 3 119 117 5 11.9 118 7 12fll 119 9 120 120 11 12£1 119 DAILY AVERAGE VALUES 13 121!1 119 15 12121 119 17 121!1 118 19 119 117 21 119 117 23 119 117 25 118 117 27 119 117 29 119 118 31 120 119 33 120 119 35 120 119 DAILY AVERAGE VALUES 37 1210 118 39 119 117 41 119 118 43 119 117 45 118 116 47 118 117 49 118 116 51 118 116 53 118 11-6 55 117 116 57 117 115 59 116 114 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.9 6.9 6.9 7.0 7.0 7.0 7.0 7.£1 7.0 7.0 6.9 6.9 6.9 6.8 6.9 6.9 7. f21 7. Jll 7.0 6.9 7.0 6.9 6.9 6.9 6.8 6.8 6.8 6.8 6.8 6.7 6.7 6.6 6.8 CHAN 2 DEG C. ------------ 6.7 6.7 6.8 6.9 7.0 6.9 6.8 6.9 6.9 6.8 6.7 6.7 6.7 6.7 6.7 6.8 6.9 6.9 6.9 6.8 6.8 6.7 6.6 6.7 6.6 6.7 6.6 6.6 6.6 6.6 6.5 6.4 6.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DIHE TIME _______ .. __ ------------------ l.l!i/121lt/86 1?.11: !~10 1121/1214/86 1!13: 1!11!1 1121/ 1!14 I 86 1215: QliZI 1!2l/IZI4/86 1!17: 121121 Hi/ ~li 4 / 86 Ill 9 : l!l!Zi Hl/1!14/86 11: !M!I UZl I 1214/86 1 3: J!i0 lill/ 04 I 86 15: 01!1 H:l/04/86 17: Y.l~!l Hl/04 I 86 1 9 : I!H!I 10/1!14/86 21: IZI!ll Hl/1!14/86 23: !Zll!i i ~~I 1215/86 IZil : 01!1 lQI/~15/86 0::>: t-3121 Hi/1!15/86 1!15 ~ 0QI l.lt.l/05/86 },~17: 00 11!1 /1215/86 ~.:19: 121121 UZI/12!5/86 11:01:!1 11!)/1!15/86 1~5:1!1121 1 i!l/ 1215/86 15: 1!10 11:!1/05/86 17: 1211!1 Hl/!!15/86 19: 01!1 11!1/05/86 21: l!liZI lal/Y.I~5/86 23: :211!1 11!1/06/86 101: 12>0 H1/1!16/86 1213: I!H!i Hl/!216/86 !i.l5: 0121 1!21/1!16/86 1!17: 0!21 U?/06/86 !219: IlliZI 11!11 1!16/86 11 : l!llll 1121/1!16/86 13:0121 Hi/1216/86 15: 121121 U!l/1216/86 17:f.!l0 11!1 l 1216 I 86 1 9: V.ll!l 1!21 / 06/86 21 : !2lJ!I Hi/!!.16/86 23: 1!11!1 BYTE RAW DATA ========== 61 116 113 63 115 112 65 114 112 67 114 112 69 114 112 71 114 112 73 114 111 75 114 112 77 114 112 79 114 112 81 114 113 83 114 112 DAILY AVERAGE 85 114 112 87 113 1 HI 89 112 1!!19 91 112 109 93 111 lf!l8 95 11!21 107 97 11121 11!16 99 110 1!06 11211 110 11!17 103 11121 108 11.!15 111 1J!j9 H17 111 11218 DAILY AVERAGE 109 111 108 111 110 107 11.3 115 117 119 121. 1Ql9 Hl6 109 106 108 1Ql5 107 1rl14 107 11!14 107 11214 125 11218 11215 127 108 11!16 1.29 1£19 107 131 109 HiS DAILY AVERAGE VALUES Vl4LUES VALUES CHAN 1 DEG C. ------------ 6.6 6.5 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.3 6.2 6. 1 6. !21 6.0 6.0 6. ~I 6. Ill 6. 1 6.1 6.1 6.1 6. Y.l 5.9 5.9 5.8 5.7 5.7 5.7 5.8 5.8 5.9 5.9 5.9 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ====== 6.3 6.2 6.2 6.2 6.2 6.2 6. 1 6.2 6.2 6.2 6.3 6.2 6.2 6 ? . - 6. lil 5.9 5.9 5.8 5.7 5.6 5.6 5.7 5.8 5.9 5.8 5.8 5.8 5.7 5.6 5.6 5.5 5.4 5.4 5.4 5.5 5.6 5.7 5.8 5.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME --·--------------===== 10/1217/86 ~H: 0!2i 1liU 1!17 /86 !213: IZllo l!!lh!i7/86 05: 1~10 Hl/1217/86 !217:01!1 Hl/!li7/86 1219: 0L:, 11!1/£!17/86 11: !21121 Hi/k?7/8c) 13:f21!:':1 Hi/1Zi7 /86 15: 121121 Hl/07/86 17:00 1!9/07/86 19: QIQI 1Y.l/IZJ7 /86 21:00 Hl/!2!7/86 23: 1!11!1 HI/ !!18 /86 1211 : l?ll2i 1121/ 1218 / 86 !213 : 00 lfZI / Y.l8 /86 Qf5: 00 1121h!l8/86 07:0121 Hl/1!18/86 1219:121121 11.21/ ~,8/86 11 : 1!1121 112l/lf.i8/86 13: lill!l 10/~,8/86 15: 1:!1121 Hl/1!18/86 17: !21121 l!ll/,~8/86 19: !!1~!1 !Qi/08/86 21: Qlfll Hl/!218/86 23: !ZIIZI li!l/ 1219/86 J!i 1 : Y.l0 115/!?!9/86 1213: !lH!I Hl/1219/86 05: 01!.1 lei I !219 I 86 1!17: Qil!l Hi n.:19 /86 09.: IlliZI 11!1/1!19/86 11: 1!10 11!1/!!19/86 13: 0li! Hi/!!19/86 15:00 1 Ql/f!>9 /86 17: 1!11!1 1!21/19'~ /86 19: 010 Ull/1!19/86 21.:0~::1 bD/!2S9/86 23:1!1!!! BYTE RAW DATA ========== 13:3 111!1 HIS 135 11121 11!18 137 1 HI 1!218 139 110 109 141 110 108 143 1 Hi HIS 145 111 Hl9 147 111 1Ql9 149 112 11121 151 112 111 153 112 112 155 113 112 DAILY AVERAGE VALUES 157 112 111 159 112 111 161 112 11121 163 112 109 165 111 109 167 111 HIS 169 111 108 171 111 109 1 73 111 11121 175 112 111 177 112 111 179 112 111 DAILY AVERAGE VALUES 1 81 112 llll9 183 111 11219 185 111 108 187 110 llll7 189 11fll 108 191 1 HI 1QI8 1 93 111 lf!l9 1 95 1 12 1 1121 197 112 110 199 112 111 2~~11 11:3: 112 21!13 114 114 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6. Ql 6. 1!1 6.0 6. 1!1 6.0 6. 121 6.1 6.1 6.2 6.2 6.2 6.3 6.1 6.2 6.2 6.2 6.2 6.1 6.1 6.1 6.1 6.1 6.2 6.2 6.4 6.2 6.2 6.1 6.1 6. 121 6.0 6.1:!1 6.1 6.2 6.2 6.2 6.3 6.4 6.2 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ------------ 5.8 5.8 5.8 5.9 5.8 5.8 5.9 5.9 6.0 6.1 6 ,., ..... 6. 1. 6. 1 6. !21 5.9 5.9 5.8 5.8 5.9 6. Ill 6.1 6.1 6.1 6. J!l 5.9 5.9 5.8 5.7 5.8 5.8 5.9 6. Ill 6. !:':! 6. 1 6.2 6.4 6.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TII"IE --------------------------- Hi/Hl/86 Y-Jl:V.l!-?1 1 Ql I 1 iZ! /86 1213: IZHZl HI /Uo /86 1215: !211~i 10 I 11!1 I 86 f2S7 : IZH21 il!l /1 0/ 86 Ql9 : 00 11!1 I 11!1 I 86 1 1 : i!lfll lQf /Hi /86 13: !lfllS 11!11 10/86 15:00 10/lY.I/86 17:012! l!ll/ Hl/86 1 9: !21121 l!l!/lQI/86 21:0fll lQl/ lQi/86 23: 0!21 HI I 11 /86 1211 : 121121 11!1/11/86 03~0f21 1!2!/ 11 I 86 !215: 121121 !Jll/11 / 86 (lj 7 : 0t!l l!Zl /11/86 1219: 0121 1!21/11 /86 11: 1210 Hl/11/86 13:!21121 11!1/11/86 15:00 11!1/11/86 17:0121 lf!l/11/86 1.9:00 HI/ 11/86 21: !!1!21 H.!l/11/86 23:0fi.i H!i/ 12/86 !Zll: 00 1121/12/86 03: !!10 HI/ 12/86 !215: 1210 10/12/86 07a%1 lfil/12/86 09:00 l!ZI/12/ 86 11: 0iZl 10/12/86 13:!210 Hi/ 1 2 / 86 1 5 : t!l!ll 1121/12/86 17:Y.I0 HI I 1 2/86 1 9 : IZil!i 1!21/12/86 21:Y.I0 Hi/ 12/86 23: ~~ltZl BYTE RAW DATA -------------------- 2tll5 116 116 21!17 11 8 11 7 21219 118 11 7 211 118 116 213 118 116 215 117 116 217 117 116 219 117 116 221 117 116 223 117 116 225 118 116 227 117 116 DAILY AVERAGE VALUES 229 117 116 231 117 116 233 117 116 235 116 116 237 117 116 239 117 116 241 117 116 243 116 116 245 117 116 247 117 115 249 117 116 251 117 115 DAILY AVERAGE VALUES 'jC""':" 4V·-' 255 257 259 261 263 265 267 269 271 117 115 117 115 117 115 117 115 117 115 117 115 117 115 117 115 117 115 117 115 273 117 115 275 117 115 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.6 6.8 6.8 6.8 6.8 6.7 6.7 6.7 6.7 6.7 6.8 6.7 6.7 6.7 6.7 6.7 6.6 6.7 6.7 6.7 6.6 6.7 6.7 6.7 6.? 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ====== 6.6 6.7 6.7 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.5 6.6 6.5 6.6 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 5 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH TIME ----------------===== H!/ 13/86 !!11: Ql0 l!!j/ 13/86 !213: 1!1121 1121/13/86 (!15: 1(.10 lQl/13/86 1217:121121 lQI/13/86 l1.19: 0f!l 1.1~1/ 1:3/86 11: IZIIZI 10/13/86 13:00 Hi I 1 3 I 86 1 5: !210 10/13/86 17:00 1121 I 1 3 I 86 1 9 : 1!10 HI/ 13/86 21:00 H)J 13/86 2:;.:;: Y-10 Hl/14/86 !!11 :IlliZI 10/1.4/86 1213:1210 11!1 I 1 4 I 86 05 : 1!1!!1 10/ 14/86 1217: IZIIZI Hl/14/86 Y.l9: 0121 li!l/1.4/86 11:1ZI0 HI/ 14/86 13: 0121 llZI/ l. 4 /86 1 5: 12!11.1 hl I 1 4 / 8 6 1 7 : 0121 1121 I 1 4/86 1 9: IZI0 1121/14/86 21: 0f!l 10/14/86 23:00 1 J!l I 1 5 / 86 IZI 1 : 00 10/15/86 QJ:::;;: 121!21 lfll/ 15/86 1215: 01!.1 HI I 15 I 86 !El7: till!! l!II/15/86 V.19:to0 Hi/ 15/86 11: ~!lf?.l 11!1 / 1 5 / 86 1 :~:;: 00 H!i / 1 5 /86 15: I!IIZI 11!1/1 5 / 86 1 7 : 01!1 Hl/15/86 19: Qlf21 liZ!/ 1 5 / 86 21 : 00 HI/ 15/86 2:;.\: !!IIZi BYTE RAW DATA ==== ========== 277 116 115 279 116 115 281 116 115 283 116 114 285 117 115 287 116 115 289 116 115 291 116 115 293 116 114 295 116 114 297 116 114 299 116 114 DAILY AVERAGE VALUES 31ZI1 31213 305 307 309 116 114 116 114 116 114 116 114 116 114 311 115 113 313 116 114 315 116 114 317 115 113 319 115 113 321 115 113 323 115 113 DAILY AVERAGE VALUES 325 115 113 327 115 113 ~:\29 115 11 ~5 331 115 113 333 115 113 335 115 113 337 114 112 339 114 1.12 341 114 112 343 114 112 345 114 112 347 114 112 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 6.6 6.6 6.6 6.6 6.7 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.5 6.6 6.6 6.5 6.5 6.5 6.5 6.6 6.5 6.5 6.5 6.5 6.5 6.5 6.4 6.4 6.4 6.4 6.4 6.4 6.5 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ====== 6.5 6.5 6.5 6.4 6.5 6.5 6.5 6.5 6.4 6.4 6.4 6.4 6.5 6.4 6.4 6.4 6.4 6.4 6.3 6.4 6.4 6.3 6.3 6.3 6.4 6.3 6.3 6.3 6.3 6.3 6.3 6.2 6.2 6.2 6.2 6.2 6.2 6.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DAlA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME ·----------------------------- l.JZi/1.6/86 fiH:00 1(!1/16/86 QS3:1ZII2l 1.0/16/86 !215: 00 Hl/ 16/86 07: 1!1121 10/16/86 09:1!10 HI/ 16/86 11: Qj0 10/16/86 13:1210 ll!l/ 16/86 1 5 : fll!!i 10/16/86 17:00 11!1/16/86 19:1!1121 1!!l/16/86 21:00 Hl/16/86 23:121121 Hl/1 '7 /86 (Zil : l!ll!l lQI/17 186 !213: 00 H~ I 1 7 /86 k.?5: f!i!ll 1!21/ 17/86 !ll7: 0~1 Hl l 1 7 /86 09: 0121 H!f I 17/86 11: 00 Hi/1 7186 13: 1!1121 lfi.l / 1 7 I 86 15: !210 H1/17186 17:01!1 Hll17186 19:1210 lQI / 1 7 /86 21 : fll0 liZl/]. 7/86 23: 0!21 Hil18186 1211:00 11!)/18/86 !Z13: !li!Zl liZJ/ 18/86 1!15: 00 Hi/ 18 I 86 07: 00 1(1/18/86 09:00 Hl/18/86 11:1Zll!l Hi/1.8/86 13: !2S0 1!21/ 18/86 15: fllY.I lY.I/18/86 17:00 li!l j 1 8 / 86 1 9 : 00 1!21/18/86 21:!!l0 1 !21/18/86 2:3;: 0121 BYTE RAW DATA ==== ========== 34'7 114 11:::: .351 114 112 353 114 112 355 114 112 357 114 112 359 114 112 361 114 112 363 114 112 365 114 112 367 113 11 l. 369 113 112 371 113 112 DAILY AVERAGE VALUES 373 113 111 375 113 111 377 113 111 379 113 :1.11 381 112 111 383 112 110 385 112 1 HI 387 112 1 H.!S 389 112 11!19 391 112 109 393 112 1!219 395 111 109 DAILY AVERAGE VALUES 397 112 110 399 111 H!l9 41H 111 11!19 403 111 1ll19 405 111 109 407 111 1.08 412'19 111 108 4 11 1 HI 11!18 4 1 3 11 1 11218 415 111 U!l8 4 1 7 1 11 11218 419 111 U!l8 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.4 6.3 6.3 6.4 6.3 6.3 6.3 6.3 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6. 1 6.1 6.1 6.1 6. 1 6.1 6. {!I 6.1 6.1 6. 1 6.1 6.1 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11 I l. 9/86 11 : 45 CHAN 2 DEG C. ====== 6.3 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.1 i.. " ........ 6.2 6.2 6. 1 6. 1 6.1 6.1 6. 1 6. Ill 6.0 6. £1 5.9 5.9 5.9 5.9 6. Qj 6.0 5.9 5.9 5.9 5.9 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-29-·86 DATA FILE : RI FFLE!!15 BHADLEY LAI<E HYDHO PROJECT START: 1(1/01 /86 13: I!HZl BRADLEY RIVER -RIFFLE REACH STOP: 11/19/86 11:45 CHAN 1 CHAN ~) ..,_ DATE TIME BYTE RAW DATA DEG c. DEG c. __ .. ___ , ___ ----------========== ------====== ·--------··------------ 1!3/19/86 Q! 1 : !Ell!> 421 110 1.1218 6. l!l 5.8 l!!i/19/86 !!l :]; : t!ll·!l 423 11121 11!18 6. 121 5.8 HI/ 1<n86 1!15: lc%1 425 1 HI 108 6.0 5.8 11!1/ 19/86 1!17: 0!!1 427 11121 11!18 6. 1!1 5.8 H9/19/86 09: 121!:? 429 111!1 108 6. !~I 5.8 1l?.i/1 ·;; /86 11 : l!H!l 431 11!21 1 1!17 6.0 5.7 H!l/ 19/86 13: !Zl!ll 433 111!1 11!17 6.0 5.7 H5/ 19/86 15: I!Hll 435 109 1f!16 5.9 5.6 H>ll.9/86 17: 1210 437 109 11?.17 5.9 5.7 ll!.l/19/86 19: 01!1 439 109 1Y.l6 5.9 5.6 1121/1.'7'/86 2l. ; IlliZI 441 Hil9 llll6 5.9 5.6 10/1 '7/86 2:3: l!lQl 443 11!19 11!16 5.9 ""' . woO DAILY AVERAGE VALUES 6. ~~~ .,. -...J • I 11!1/21!.1/86 1!11 : IZI!Zl 445 11219 1!216 5.9 5.6 1 Ql/2~1/86 IZl3: l!H!i 447 11219 106 5.9 5.6 11!1/2121/86 f215: !!lfZI 449 109 1v.16 5.9 5.6 10/2121/86 1!17: (!10 451 Hl9 106 5.9 5.6 1121/21!1/86 Jll9: f2lfll 453 109 1!216 5.9 5.6 Hl/2t1/86 11 : 12)0 455 11219 106 5.9 5.6 1125/ 21!1/86 13: 1!1121 457 108 1QI5 5.8 5.5 10/21Zi/86 15: 121111 459 108 105 5.8 5.5 1 !21/2i21 /86 1 7: f!11!1 461 112!8 1!215 5.8 5.5 1QI/2QS/86 1 9: 121121 463 1!218 105 5.8 5.5 li?i/21!1/86 21 : l!ll!l 465 H18 1P.l6 5.8 5.6 H!l / 2lZI/86 23: 1!1121 467 1!218 11215 5.8 ~ c· '-low DAILY AVERAGE VALUES 5.9 5.6 1121/21/86 v.s 1 : a'l!' 469 108 11215 5.8 5.5 l!M21/86 !213 : S!l !!l 471 1!!19 1QI6 5.9 5.6 H9/21/86 1!!5 ~ l!l!!l 473 11ZI8 106 5.8 5.6 Hl/21 /86 07: !ZII!l 475 108 11!16 5.8 5.6 H!l/21 /86 1!19: 0Ql 477 HIS 106 5.8 5.6 Hl/21 /86 11 : !!li2l 479 109 11!16 5.9 5.6 Hl/21 /86 13: 1-!HZl 481 108 Hl5 5.8 .,. c.- ..Jo..J lY.l/21 /86 15: fl.H!I 483 1 !!18 1Ql6 5.8 5.6 l. V.l/21 I 86 1 7: 19~~~ 485 109 H!l7 5.9 5.7 i!il/21 /86 19: 01~1 487 11!18 11!16 5.8 5.6 11!1/21/86 21: !21!21 4·89 Hl9 1!216 5.9 <::' ' -.~.o Hl/21/86 2.:;;;: i!H!l 491 11!18 1.e16 5.8 5.6 DAILY AVERAGE VALUES 5.8 5.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-29-86 DATA FILE : R I FFLEr2!::':, BRI-1DLEY U-11<E HYDRO PHOJECT START: Hlh.~1 /86 13: !2!!21 BRADLEY Rl\JER -RIFFLE REACH STOP: 11/19/86 l1:.:1·5 CH1-'\N 1 CHAN ,.., . .:. DATE T Il'1E BYTE RAW DATA DEG c. DEG c. .. --··---··-.. --. ===== --~------------____ .. __ ------__ .. ______ ------------------~---- Hl/22/86 01: k~Q! 493 108 1 !216 5.8 5.6 1 ~~1/22/86 o::::;: 121121 ·'195 1QI8 11!16 5.8 5.6 l.!Z!/22/86 k.IJ5: 0!3 497 HIS 106 5.8 5.6 10/22/86 !!17: !0!21 499 uo9 1 !!16 5.9 5.6 Hl/22/86 Ql9: 1()!21 51!11. HIS 1Ql6 5.8 5.6 1 ~?l/22/86 11 : !!10 5!213 HilS 11!16 5.8 5.6 1(1/22/86 1 3: IZIJ!i 51215 l!ZIS 106 5.8 5.6 1 IZI/22/86 15:f21!2! 507 1Ql8 Hi6 5.8 5.6 11!1/22/86 17: !2!0 5!219 109 106 5.9 5.6 lf!l/22/86 1 9: 121!21 511 108 11!16 5.8 5.6 H:J/22/86 21 : IZI,~! 513 1 1!19 106 5.9 5.6 1 !21/22/86 23: 0!2! 515 108 1 !!16 5.8 5.6 DAILY AVERAGE VALUES 5.8 5.6 1!25/23/86 Y.! 1 : 121!21 517 1Qf9 Hl6 5.9 5 .. 6 1!2i/2:S/86 f.i 3 : l!llil 519 1(?9 11217 5. ''t 5.7 1!!1/23/86 Ql5: {(.1!!1 521 1!219 1!216 5.9 5.6 Hl/2~$/86 !217: ~?!9 523 109 106 5.9 5.6 Hi/23/86 1!19: QIIZI 525 11!!9 11216 5.9 5.6 Hl/23/86 l. 1: Ql~l 52'7 109 11216 5.9 5.6 1 QI/Z3/86 13: QIQI 529 1!99 1 i216 5.9 5.6 Hi/23/86 15: QIY.I 5:::1 108 11!16 5.8 5.6 1 Q!/2::)186 17: 0~1 533 11219 1QI7 5.9 5.7 Hl/23/86 19: f.!HZI t:"':"C' ...... •· .. ),.,J 109 106 5.9 5.6 Hl/Z5/86 21 : Qlf.!l 537 1!218 11216 5.8 c:-.• ...JoO Hl/2:3/86 23: 0!3 ~j::::9 11219 106 5.9 5.6 DAILY AVERAGE VALUES 5.9 5.6 UZ!/24/F.lb i!11: 00 ::i41 1 1!19 1QI6 5.9 5.6 1 kl/24/86 !213: 121!!1 54::::: 1199 1 [!16 5.9 5.6 l!il/24/86 l!l5: 0~:1 ~545 1"19 1!:36 5.9 5.6 1!!1/24/86 IZJ7: 121121 547 11Z19 11!16 5.9 5.6 11!1/24/86 09:00 549 11219 1 !!16 5.9 5.6 Hl/24/86 1.1: 0Ql 551 :l.l!f9 106 5.9 5.6 J.Ql/24/86 1 3: l!.l!2i 553 HiS 1 1!16 5.8 5.6 Hl/24/86 15: !Zll21 555 11!18 1k16 5.8 5.6 1121/24/86 1 7: Y.112i 557 11218 Hl6 5.8 5.6 Hl/24/86 1 9: 1!1!21 559 1QI8 11!15 5.8 5.5 1121/24/86 21: 1!.10 561 1!218 l!!S6 5.8 5.6 Hl/24/86 23: 121121 56~.5 11!i8 l!l>5 5.8 t::' r:::· ...Jo...J DAILY AVERAf3E VALUES 5.9 ""' , ...J.O ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME .. --·----·------------·-----·---- lQI/25/86 !!ll: !M!i l!!.l/2:'i/86 !Zl3: i2>fZ) 1 ~~j /25/86 1!15: 0,, Hl/25/86 1217: IlliZI Hl/25/86 1219: 0121 ll!l/25/86 11: 121!21 1!21/ 25/86 13: Y.lij Hi/25/86 15: 0121 UZS/25/86 17: 0~!1 Hl/25/86 19:0121 lil!/ 25/86 21: 12l!Zl 1!2! /25/86 23: IZHZ! 11!1/26 /86 1211 : lllV.l 11~l /26/86 1213: ti,lj!l 1 Ill/ 26/86 12l5: !!5121 l.Q!/26/86 ~!i7: 0121 Hi/2b/86 Ql9: 121!21 Hl/26/86 11: 0121 11!.1/26/86 13:0121 Hi/26/86 15: 0l:."l Hl/26/86 17: 121121 1.121/26/86 19:12111.1 1121/26/86 21: 1!10 1 Y.l/26/86 23: f:?l!l U!l/27/86 01:!2SQI Hl/27 /86 V.S:3: 0121 1Ql/27/86 05:0121 lW/27/86 !!17:V.I!!i uzs /2 7 /86 !~19: ll10 Hl/27 /86 11: 1!1!21 1!!1 / 2 7 l 86 1 3 : !c!I!ZI Hl/27/86 15:1!1!21 1.(~/27/86 17: ti.S~.!l l !!1/27 /86 19: !Ml l~Zl/2?/86 21:(?~!1 lW/27/86 23:121121 BYTE 565 567 569 571 5~7 5 577 579 581 583 585 RAW DATA -------------------- 1!Z18 1. !215 1 1218 1 tZ15 108 H!l6 108 li!15 1 1217 11215 11217 1 f!l5 1Li1"7 105 1 Ql7 U214 107 104 l!Zl7 11!14 107 104 587 11217 104 DAILY AVERAGE VALUES 589 107 104 591 107 104 59::::: 11217 H!l4 595 106 11!14 597 106 11!14 599 106 104· 61!11 1l!S6 11!14 603 105 ·103 6Y.l5 105 103 61217 105 102 6!219 105 103 611 105 H!l2 DAILY AVERAGE 613 U!15 102 615 11!15 11!12 617 105 102 61 9 11215 H12 621 1QI5 11!12 623 104 11!11 625 11!14 101 627 104 1!!11 629 11!14 1Y.I1 631 1 !!14 ll2i 1 633 104 Hi 1 635 1fY3 l!!:JU1 VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 5.8 5.8 5.8 5.8 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.6 5.6 5.6 5.6 5.5 11::" 11::" ...~ . ...~ 5.5 5.5 5.5 5.6 c:-.,. 1..J ., ~.J 5.5 C::" =: ...~ . ...~ 5.5 5.5 5.4 5.4 5.4 5.4 5.4 5.4 5.3 5.4 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11 / 1 9/86 11 : 45 CHAN 2 DEG C. ====.::::::= 5.5 c::· 1:::" -·· ""'} 5.6 5.5 5.5 C" .,. ...~ . ...~ 5.5 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.4 5.3 5.3 5.2 5.3 5.2 5.3 5.2 5.2 5.2 5.2 5.2 5.1 5.1 5. 1 5. 1 5. 1 5.1 5.121 5.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 112i 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T I 1'1E ---------__ ,. __ _ ------------- l.ll!/28/86 1211: 0Jli Hi/ 28/86 !213: 1?1121 10/28/86 !::15: ~~it?! 11!! /28/86 1217: l!li!i 1!21 /28/86 ~~19: 01!1 l!.?i/28/86 11:121121 Hl/28/86 13: Y-10 HI/ 28/86 15: QIIZl 11!5/28/86 17: 00 lQl/28/86 19: 1210 ll!i/28/86 21.:130 Hl/28/86 23: Y.IQl l!!i/29/86 !211: 00 Hi/29 /86 03: 00 Hl/29 /86 1!15: 01!1 10/29/86 1217: 0~1 11!1/29/86 1!19: !!l!ZJ H.:l/29 /86 11: IZikl l!ll/29/86 13: 1!11!1 HJ/29/86 15:00 1121/29/86 17: l!l&ZI U?.l/29/86 19:00 Hi/29 /86 21: 01!1 lQI/29/86 23:00 Hl/30/86 ~H: 00 Hl/31!1/86 03: !!10 li!I/:3Lil/86 05:00 HS/30/86 07: @21 112!/:;';~;.?/86 09:0121 l!(.J/:3!~1/86 11: kll!l H!/31?.1/86 13: ~~0 10/31!1/86 15:0!2} 1!21/30/86 17:QI0 HI/3QI/86 19: 0!!1 1 iZi / 3!!1 / 86 2 1 : 1211:~1 Hl/31!1/86 23: 1!1121 BYTE RAW DATA ========== 637 uzs:::; l!ZH 639 11!13 1!!11 641 10:3 Hll 643 11.!13 11!11 645 103 11210 64 7 103 11?11!1 649 H:!i3 100 651 11!'!3 10121 653 102 10QI 655 102 100 657 11!12 99 659 11!12 99 DAILY AVERAGE VALUES 661 1Y.J2 99 663 102 99 665 11!11 99 667 Hl1 99 669 101 99 671 101 98 673 101 98 675 101 98 677 11210 98 679 U!ll 98 681 11!11 98 683 1 li.ll!l 98 DAILY AVERAGE ~ALUES 685 101 98 687 101 98 689 li!H!l 98 691 10121 98 693 100 97 695 10!!! 97 697 100 98 699 11!11!1 97 71211 101ZI 97 7t2f3 11v1zs 97 71!15 99 97 71!17 11!11!1 97 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 5.3 5.::::: 5.3 I!::' "':'" ._J. ·-' 5. Z\ 5.3 5.3 5.3 5.2 5.2 5.2 5.2 5.3 5.2 5.2 5. 1 5.1 5.1 5.1 5.1 5.1 5. Y.l 5.1 5.1 5. 1!1 5.1 5.1 5.1 5.0 5.121 5.0 5.0 5.0 5. Y.l 5.0 5. I!! 4.9 5. Ill 5.0 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ___ , __ _ ------- 5. l 5. 1 5.1 5. 1 5.0 • 5.!0 5. ~, 5. !!I 5. ~j 5.0 4.9 4.9 5.0 4.9 4.9 4.9 4.9 4.9 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.7 4.8 4.7 4.7 4.7 4.7 4.7 4.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME __ .. _______ -·--·--------·------- lQl/31/86 j!l1.:0W 1121/31/86 l!i3: Q!Ql 1 ~ZI/31 /86 1!15: QIQI HI/ 31/86 l!l7: ~!H'!I i!!l/31 /86 09: 0!1.1 Hll31 186 11: QIQ! 1 ~?131 /86 13: 0Qi l!Zl/ 31 I 86 15: 1!1121 1121/ 31 I 86 1 7: 0121 lQI/31/86 19:1!1!!1 J.Qi/31/86 21:00 Hl/31/86 23:1!H!I 11 hZ11 186 1211: !!1121 11 /1:?1 /86 !!f3: 00 11 /1!11 186 1215: f210 11 /f:?l 186 07: 0!21 1 1 / 1211/86 1!19 : 1210 11/1211/86 11:j.!IQ! 11 /!!11 /86 13: 0f21 1 1 I 01 I 86 15 : 1210 1 1 / 1211 I 86 1 7 : I!IQI 11 /1211 /86 19: 00 11 11!11 /86 21: !!1!!1 11 /!!11 186 z:;;;: 00 11/1212186 j.;!: 00 11 I fZ12 I 86 !213: 1210 11/1212/86 !215: 0f!i 111!212186 !!17:121Y.I 11/~212186 !219:00 11 /1!12186 11: 0121 11 /~l2/86 13: 1!1!21 11/02/86 15: 1211!1 111!'212186 17:00 11/1!'2/86 19: !lifE! 11./t~l2/86 21:121!21 11/!!12/86 23: IZI!!I BYTE RAW DATA ========== 71!19 100 96 711 1QII2l 96 713 99 96 715 99 96 717 99 96 719 99 96 721 98 95 723 98 95 725 98 95 727 97 94 729 98 94 731 98 95 DAILY AVERAGE VALUES 733 98 9!::· 735 97 94 737 97 94 739 9"7 94 741 97 94 743 97 94 745 97 94 747 97 93 749 96 93 751 97 94 753 98 94 755 98 94 DAILY AVERAGE VALUES 757 98 94 759 98 95 761 97 94 763 98 94 765 98 95 767 98 95 769 98 95 771 99 96 773 99 95 775 98 95 T77 98 96 779 98 95 DAILY AVERAGE VALUES CHAN 1 DEG C. -·----------- 5.0 5. ill 4.9 4.9 4.9 4.9 4.8 4.8 4.8 4.7 4.8 4.8 4.9 4.8 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.6 4.7 4.8 4.8 4.7 4.8 4.8 4.7 4.8 4.8 4.8 4.8 4.9 4.9 4.8 4.8 4.8 4.8 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ------------ 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.5 4.5 4.4 4.4 4.5 4.5 4 1::' . ...~ 4.4 4.4 4.4 4.4 4.4 4.4 4.3 4.3 4.4 4.4 4.4 4.4 4.4 4.5 4.4 4.4 4.5 4.5 4.5 4.6 4.5 4.5 4.6 4.5 4.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1.2 12-29··,86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME -----------·--------·------- 1 1 / !{i:::;. /86 Qi 1 : '.90 11/1!.13/86 IZl3:\!lt!i 11 /QJ:::,;/86 1~15: 1210 11 /12!3/86 1217: Q!Ql 1l./!1i3/86 ~!J9: 00 11/!!1::::/86 11:0!2! l. l /1!53/86. 13: {{.10 l. 1 /!213/86 15: 1.!10 11/1~13/86 17:0121 11 I 03 I 86 1 9: IZlQI 11/l!l~::./86 21:00 11/!2!3/86 23:1!!1!1 11 /194/86 l:~l1: 0!!1 11 /~94/86 03:00 11 /lll4/86 05: 01!! 11 / Q!4 I 86 Ql7: 1211.~1 11 /~!14/86 (i!9: l!l!Zl 11/!!.14/86 11: 0f-9 11/1214/86 13: !!10 11/04/86 15: !!H!I 11/1214/86 17: Y.S!Zl 11n.?4/86 19:00 11 /1!14/86 21:100 11/1!54/86 23:011.! 11/~il~.:i/86 !lll:12!Ql 111 1!15 I 86 1!13: l!ll!l 11/l!i5/86 1!!5: 00 11 /1!15/86 1217: 0!!i 11/05/86 12!9:0121 11/1!15/86 11:Qll!l 1.1/05/86 13:1!10 11/1Zl5 /B6 15: 1?1121 11 / 1215/86 1 7 : 00 11 /!215/86 19: !ll!!l 11/1215/86 21: !2@ 11/1215/86 2:::::: Ql!!l BYTE RAW D{HA ___ .. ____ .. __ _ ---------- 781 98 96 783 98 96 785 98 96 787 98 96 7'89 99 96 791 99 97 ~'93 99 97 795 99 97 797 99 97 799 99 97 8k!l1 112H} 97 81213 10121 97 DAILY AVERAGE VALUES 8!!15 10Y.i 97 8f~l7 100 97 809 1~<:11!1 98 811 100 98 813 1Ql0 98 815 11211!1 98 817 115121 97 819 100 98 821 100 97 823 100 98 825 Hl0 98 827 11210 98 DAILY AVERAGE VALUES 829 100 98 831 10121 98 83~5 11!10 98 835 11!HZI 98 837 100 98 839 11210 98 841 112"10 98 843 11!!121 98 845 10121 98 84 7 HIIZI S19 849 1121121 98 851 11Zi1Zi 98 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------- 4.8 4.8 4.8 4.8 4.9 4.9 4.9 4.9 4.9 4.9 5.0 5. yj 4.9 5. !!i 5. I{) 5. Ill 5.0 5. l2l 5.0 5. 1!1 5.0 5.0 5.0 5. 1!1 5.~ 5. IZI 5. t2l 5. Ql 5.0 5.0 5. Ill 5. 1!1 5.0 5.0 5. 121 5. 121 5. !!I 5. 1!1 5. f21 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. __ H_ .. _ .. __ ------ 4.6 4.6 4.6 4.6 4.6 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.8 4.8 4.8 4.8 4.7 4.8 4.7 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.9 4.8 4.8 4.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page:! 1::: 12-29-E3C: BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE Tlt1E ---·------~-·---------------- 11 /1!16/86 IH: !21121 11/!!16/86 Ql3: i!ll!l l.l./1?16/86 C!.l5:01!.l 11/1!16/86 !!17: !21!!1 11/QJ6/86 W.!9!l!HZ! 11/1!16/86 1 1 : 0!!1 11/1!!6/86 1:::Y.J0 11/1!'6/86 15:1!1Ql 11/06/86 17:Y.l1Zl 11/1!16/86 19:0~~~ l. 1/1!!6/86 21: QIY.i 11/1!16/86 23:!::10 11 /!!17 /86 01: 0i!l 11 /ll!7 /86 Y.l3: Qi0 11 / !!17 /86 1215: Qll!i 11/!217/86 Ql7: 0!21 11/!!17/86 1219:1210 11/1217/86 11:00 11/1217/86 13:~1!21 11/1!17 /86 15:00 11/!217 /86 17: 1!10 11 / ~~17 /86 19: 00 11/!217/86 21:1!11!1 11 /1!17 /86 23: 01!1 11 / lZ18 /86 ~:!!1 : !ZH21 11/QIS/86 l!i3: 1!1!!1 11 /Ql8/86 $05: !!.10 11/1!18/86 Y.I7:QIQI 11 /1!18/86 1219: I(}~?! 11/1218/86 11.; !21!21 11 h!l8/86 13: ~!1!:.1 11/1218/86 15: f!!!ZI 11 /1!18/86 17:121121 11/ !Zl8/86 19: 1!11!1 11/08/86 21: I!@ 11/~~18/86 23: V.l!Zl BYTE RAW DATA _______ .. _.,. __ ---------- 85:3 10!21 98 855 hH 98 857 HH 98 859 l!lll 98 861 101 98 863 101 98 865 1i!ll. 99 867 11!11 98 869 11210 98 871 11211 98 873 1Y.I1 98 875 101 98 DAILY AVERAGE VALUES 877 10!!1 98 879 101 99 881 lfll0 98 883 10121 98 885 1a10 98 887 101 98 889 1 Qll!l 98 891 100 98 893 11210 98 895 1 fllf2l 98 897 1 {211!1 98 899 100 97 DAILY AVERAGE VALUES 901 10QI 98 9J!l3 100 98 9!215 10~5 98 9$217 11~0 98 91219 100 97 911 10!!1 97 913 11210 97 915 99 97 917 10J21 97 919 99 97 921 99 97 923 99 97 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 5. 121 5.1 5.1 5. 1 5.1 5.1 5.1 5.1 5.1ZI 5.1 5.1 5. 1 5.1 5.121 5.1 5. f21 5.0 5. !21 5.1 5. 121 5.0 5.121 5.0 5.0 5.0 5.121 5. !21 5.1!1 5.0 5. !Zl 5.0 5. 121 5. !21 4.9 5.0 4.9 4.9 4.9 5. 121 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ------------ 4. l:l 4.8 4.8 4.8 4.8 4.8 4.9 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.9 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.8 4.8 4.8 4.8 4.8 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 14 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH D~HE TII"lE ----------------===== 1 l / 121•7' /Btl 121 1 : l?.l!-3 1. 1 1 !!19/86 !21~5: i!lr!l 11 /!219/86 Ql5: 1!>0 11/1219/86 l!l7!lMi 11 / Ql9 / 86 !219: 1210 11/IZI9/86 11:1!1121 11/189/86 1~5:1!112! 11 /1219 I 86 15: P.H!I 11/09/86 17: V.IIZI 11 I 1!19/86 1'-=1: Qlt!l 11 N!19/86 21: ~~10 11 h!19 /86 23: l!i!ZI 11/U!I/86 01:010 11/ Hl/86 11.13: 012! 11/Hi/86 1?.15:1!1QI 11 l l.t!l/86 IZ!7: Y.l0 11. /10/86 Y.>9: 1!11!1 11 / 11!1 /86 11! QIQI 11 I 10/86 13: Y.l!Zl 11 I 10/86 1 5: Qlf!i 11/ Hi/86 17: 1!1121 11/ ll!i/86 19:00 11/ 1Y.il86 21: Y.lc!l 11/10/86 23:12H!1 1 1 I 11 I 86 0 1 : !Zl!o':l 11/11 /86 1~13: Qll!l 11,:11/86 1!15: 1ous 1 1 I 11/86 iZl7: Y.lQl 1 1 / 11 I 86 Y.i9 : fll!Zl 11/11/86 11:121QJ 1 1 / 11 / 86 1 :2:.: l!iQI 11/11/86 15:0Ql 11 / 11 /86 17: 0J!S 11 I 1 1 / 86 1 9 : l!h!l 11 I 11/86 21: 01?1 1 1 I 11 /86 2:3: !Ml BYTE RAW DATA -------------------·- 925 99 97 927 99 97 929 99 97 931 99 97 933 99 97 9.;:;:5 99 97 937 99 96 939 99 97 941 99 96 943 99 96 945 99 96 947 99 96 DAILY AVERAGE VALUES 949 99 96 951 99 96 953 99 96 955 99 96 957 99 96 959 99 96 961 99 96 963 99 97 965 99 96 967 99 96 969 99 96 971 99 96 DAILY AVERAGE VALUES 9T5 99 97 975 99 97 977 99 97 979 99 97 981 99 97 983 99 97 985 99 96 987 99 96 989 99 96 991 100 97 993 99 97 995 99 97 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 4.9 4.9 4.9 4.9 4': 9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 5. P.l 4.9 4.9 4.9 DATA FILE : RIFFLE05 START: 10101/86 13:00 STOP: 11/19/86 11:45 CHAN 2 DEG C. ------------ 4.7 4.7 4.7 4.7 4.7 4.7 4.6 4.7 4.6 4.6 4.6 4.6 4.7 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.7 4.6 4.6 4.6 4.6 4.6 4.7 4.7 4.7 4.7 4.7 4.7 4.6 4.6 4.6 4.7 4.7 4.7 4.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T Il'lE ======== ===== 11/12./86 Ql1: 1!1121 11 I 12/86 Ql3: ll!QI 11/12./86 1215:00 1. 1/12/86 1217: 1!1121 11/12/86 1!19: i!H!i 1 1 I 1 2/86 1 1 : 1:?0 11 I 12/86 13: 121!ZS 11/12186 15:01!1 11/12/86 17: 0~1 11 / 1 2 I 86 1 9 : I!IQ! 11 I 12/86 21:1210 11/12/86 23:!210 11 I 13/86 1211:00 11/1:::::/86 0:::.: 01Zi 11/13./86 1!!5:1Zlll1 11/1~5/86 1217:00 11 I 13186 !219: Y.lfll 11/13/86 11:(!10 11/ 1:3;186 13:0121 1 1 / 1 3/86 1 5: 01(') 11 / 13 I 86 17: 1!1121 11/1~5/86 19:!!10 11/13 I 86 21 : ~!1!21 11113/86 23:00 11/14/86 I!H;Y.IV.I 1l I 14/86 03: !21!21 11/14/86 !215:00 11114/86 1217:1!10 11/14/86 1!19: !210 11/14/86 11:1!!Qf 1.1/14/86 13:00 11114/86 15:1!11!1 11/ 14 I 86 17: IZH~I 11/14/86 19:00 11 / 14/86 21: 01!1 11 I 14/86 23: ~IV.! BYTE RAW DATA ========== 997 99 97 999 99 97 112101 99 96 11Zlt!l3 99 97 Hlll15 99 97 101!17 99 97 112109 99 96 1011 99 96 1013 99 96 112115 99 96 H"H 7 99 97 1!2119 99 96 DAILY AVERAGE VALUES HZ!21 99 97 1023 101!1 97 11!125 99 97 1k!l27 99 97 1029 99 97 1031 99 97 1033 99 97 112i35 99 96 112137 98 96 1(139 99 96 1V.i41 99 96 1043 98 96 DAILY AVERAGE VALUES 11!145 98 96 11!147 98 96 11!149 98 96 1llf51 98 96 1053 98 96 1055 99 96 1CZ157 98 95 1~159 98 95 1Ql61 98 95 11!163 98 95 1065 98 95 11Zl67 98 95 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 5.0 4.9 4.9 4.9 4.9 4.9 4.9 4.8 4.9 4.9 4.8 4.9 4.8 4.8 4.8 4.8 4.8 4.9 4.8 4.8 4.8 4.8 4.8 4.8 4.8 DATA FILE : RIFFLE05 START: lQI/!211 /86 13: !liQ! STOP: 11/19/86 11:4~1 CHAN 2 DEG C. ------· ------ 4.7 4.7 4.6 4.7 4.7 4.7 4.6 4.6 4.6 4.6 4.7 4.6 4.6 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.6 4.6 4.6 4.6 4.6 4.7 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.5 4.5 4.5 4.5 4.5 4.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-29,.,86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH TIME ======== ---------- 11 I 15/86 (2!1: 0iZI 11/15/86 !213: IZl!ZI 1 1/ 1 5 I 86 IZ15: 00 11/15/86 IZ17:J!I!Zl 1 111 5/ 86 09: !lHZI 1 1 I 1 5 / 86 1 1 : !!l!!l 11 / l. 5 I 86 1 :3 : 00 11115/86 15:12l!ZI 11/15/86 17: 1!10 11 I 15/86 19: 1211!i 11./15/86 21: 1211!1 11/15/86 2::::;: QIIZI 11116/86 01:1210 11 I 16/86 !213: 00 11/16/86 05: 1211!1 11116/86 1!17:00 11 I 16/86 1219: r21QI 11/16/86 11:00 l 1 / 1 6 I 86 1 3: 0121 11/16./86 15:00 1 1 I 1 6 I 86 1 7: 0!ZI 11/16/86 19:00 11 / 16/86 21 : l!lt!l 11 / 16/86 23: Qlfll 11/17./86 1:.11:1210 11 / 1 7 I 86 1.':13: 0!!1 11/1.7/86 J!)5:0!!5 11 / 17/86 f217: 1!11!1 11/17/86 09:00 11/17186 11:121121 11117/86 13:QHo 11 I l 7/86 15: 1211!1 11 / 1 7/86 17: 121~;1 11 I 17/86 1 9: V.!IZI 11/1.7/86 21:12lr!l 11/17/86 23: 11112! BYTE RAW DATA ========== 1069 98 95 11!171 98 95 11Zf73 98 95 11!175 98 95 11-377 98 95 1121"79 98 96 1081 98 96 11Zl83 98 95 1085 98 95 112187 98 95 1k189 98 96 1091 98 96 DAILY AVERAGE VALUES 1093 99 96 1095 98 95 1V.l97 99 96 11!199 99 96 1101 99 96 1103 99 96 1105 99 96 1111.17 99 96 11!!19 99 96 1111 99 96 1113 99 96 1115 99 96 DAILY AVERAGE VALUES 1117 99 96 1119 98 96 1121 98 95 1123 98 95 1125 99 96 1127 99 96 1129 98 96 1131 98 95 1133 98 95 1135 98 95 1137 98 95 1139 97 95 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.9 4.8 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.:t 4.9 4.9 4.8 4.8 4.8 4.9 4.9 4.8 4.8 4.8 4.8 4.8 4.7 4.8 DATA FILE : RIFFLE05 START: 10/01/86 13:00 STOP: 11119186 11:45 CHAN 2 DEG C. ------------ 4.5 4.5 4.5 4.5 4.5 4.6 4.6 4.5 4.5 4.5 4.6 4.6 4.5 4.6 4.5 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.5 4.6 4.6 4.6 4.5 4.5 4.5 4.5 4.5 4.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-29-86 DATA FILE : R I FFLE!!l5 BRADLEY LAI<E HYDRO PROJECT START: llll/1211 /86 13: 0Ql BRADLEY RIVER -RIFFLE REACH STOP: 11/19/86 11:45 CHAN 1 CHAN '"") .:.. D~~TE TIME BYTE RAW DATA DEG c. DEG c. --------===== ----========== ------====== -------------- 11/1.8/86 1211 : !!HZ! 1141 98 95 4.8 4 c:· • ...J 11/18/86 !213: Ql0 1143 98 95 4.8 4 c.· • ...J 11/18/86 1!15: ~:!~!> 1145 98 95 4.8 4.5 11/18/86 1Zl7: J!h!l 1147 97 94 4.7 4.4 11/18/86 09: 0Q.l 1149 97 94 4.7 4.4 11/18/86 11 : l!ll!i 1151 97 94 4.7 4.4 11/18/86 13:00 1153 97 94 4.7 4.4 11/18/86 15: !ZI!ZI 1155 97 94 4.7 4.4 11/18/86 17:00 1157 96 93 4.6 4.3 11/18/86 19: £1121 1159 96 9'"" ·-· 4.6 4.3 11/18/86 21:00 1161 96 9..,.. ... , 4.6 4.3 11/18/86 23: 0Qj 1163 96 93 4.6 4.3 DAILY AVERAGE VALUES 4.7 4.4 l.l/19/86 Ill 1 : lll!Zl 1165 96 93 4.6 4.3 11/19/86 03: 1210 1167 96 93 4.6 4.3 11/19/86 !215: 0f!l 1169 96 92 4.6 4.2 11/19/86 07: 01!1 1171 95 92 4.5 4.2 11/19/86 09:100 1173 95 92 4.5 4.2 11/19/86 11 : 1210 1175 95 92 4.5 4.2 DAILY AVERAGE VALUES 4.5 4 .., ..... ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page :l 12-29-,86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH BEGIN 085 :CHAN1=4.6 CHAN2=4.2 LOW BATT USED=1177 DATA FILE : RIFFLE06 START: 11/19/86 13:00 STOP: 12/1121/86 11:15 END OBS :CHAN1=2.2 CHAN2=1.8 CHANGED BATT FIRST BURN 1200 DATE TIME ----------------------_ .. ___ _ 11 / 1 9/86 13: 0!21 11 I 19/86 15: 01!1 11/19/86 17:00 11/1 9 I 86 1 9 : 0121 1 1 I 1 9 /86 2 1 : 0~ZJ 11/19/86 23:0121 11/21!)/ 86 Ql1: !!l!!l 11 /2~!1/86 ~!1:5: QIIZ! 11 / 2QJ /86 1215: !21!21 11 / 2Y.l /86 07: '~i!!> 11/2l~l/86 !li9:!!HZI 11/2!-!i/86 11:01!1 11/2!21/86 13:!2llll 11 / 2121 I 86 15: 00 11/2!!1/86 17:1Zl!!l 11/20/86 19:!210 11/2121/86 21 aiil!l 11 /21Zl/86 23: 0t!J 11/21/86 f!H!0121 11/21/86 1!13:!210 11/21/86 05:00 11 /21/86 !217: 1!1!21 11 /21 I 86 !2!9: 121~:1 11/21/86 11:0QI 11/21/86 13:00 11/21/86 15:00 11/21/86 17: ~:!1!1 11/21/86 19:!!l!ll 11/21/86 21:0~e~l 11/21 I 86 23: Q'l0 BYTE RAW DATA --------------------1 95 92 3 95 92 5 94 92 7 95 91 9 95 91 11 95 92 DAILY AVERAGE VALUES 13 94 91 15 94 91 17 94 91 19 94 91 21 94 91 23 94 91 25 94 90 27 94 9!21 29 93 89 31 92 89 33 92 88 35 91 88 DAILY AVERAGE VALUES 37 92 87 39 91 87 41 90 87 43 90 87 45 90 87 47 91!1 86 49 89 86 51 89 85 53 89 85 55 88 85 57 88 85 59 88 84 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 4.5 4.5 4.4 4.5 4.5 4.5 4.5 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.3 4.2 4.2 4.1 4.3 4 . .? 4. 1 4.0 4. 121 4.0 4.0 3.9 3.9 3.9 3.8 3.8 3.8 3.9 CHAN 2 DEG C. ------------ 4 '-:1 ..... 4.2 4.2 4. 1 4.1 4.2 4.2 4. 1 4·. 1 4.1 4.1 4.1 4.1 4.0 4.0 3.9 3.9 3.8 3.8 4.0 3.7 3.7 3.7 3.7 3.7 3.6 3.6 -C' • .) • >:J 3.5 3.5 3.4 3.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-29"·86 DATA FILE : RlFFLE!Zi6 BRPtDLEY LAI<E HYDRO PROJECT START: 11/19/86 r.:>: 0iZi BRADLEY R I\iER -RIFFLE REACH STOP: 12/ Hl/86 11: 15 CHAN 1 CHAN '") ..:.. DATE TIME BYTE RA~~ DATA DEG c. DEG c. --·--··-----------------------====== ----------------------------------- 11/22/86 !!i 1 : S!IC.!i 61 87 84 3.7 3.4 11/22/86 ~~!3 : l!lfil 63 87 83 3.7 3.3 11/22/86 05: 0121 65 87 82 -::-"'7 ....,, • I <· .-, ._ ........ 11/22/86 !217 : 1!11!1 67 86 82 3.6 ~ ,.., -·· ... 1.1/22/86 1!19: 00 69 86 82 3.6 3.2 11/22/86 1 1 : !!ll!l 71 86 81 3.6 3. 1 11/22/86 13: 01!1 73 85 81 ·-o:::-~.u 3.1 11/22/86 15:00 75 85 81 3.5 3.1 11/22/86 17:00 77 85 81 3.5 3. 1 11/22/.86 19: 01!1 79 84 80 3.4 3. !21 11/22/86 21: 01:?1 81 84 80 3.4 3. Ql 11/22/86 23: 0!Zi a-:r ._. 84 80 3.4 3.0 DAILY AVERAGE VALUES 3.6 3.1 11/23/86 1211 : QlfZl 85 84 79 3.4 2.9 11/2~5/86 03: 1211!! 87 83 79 3 .. 3 2.9 11/23/86 1215: Y.l0 89 83 79 ..,.. ..,.. -\· _ .. 2.9 11/23/86 1217: 01~1 91 83 79 3.3 2.9 11/23/86 1!19: 1210 93 82 78 3.2 2.8 1.1/23/86 11:00 95 82 78 3.2 2.8 11/23/86 13: 1!1&!1 97 82 78 -:r .., ""'" .... 2.8 11/23/86 15:00 99 82 78 7 .., ........ ~ 2.8 11/23/86 17: QlfZI 11Zi 1 82 78 ..,. .., ..:>o..:.. 2.8 11/23/86 19:00 103 82 77 3.2 2.7 11/2:3/86 21 : 0!Zl 1 !215 82 77 3.2 2.7 11/23/86 23: 0121 107 81 77 3.1 .., ., ..:.. • I DAILY AVERAGE VALUES ~ r') ._\. "'"" 2.8 11/24/86 01:00 H!l9 81 77 3.1 2.7 11/24/86 Qj3: @21 111 81 76 3.1 2.6 11/24/86 05:00 113 80 76 3.0 2.6 11/24/86 !ZJ7: V.H!I 115 80 76 3. l!J 2.6 11/24/86 1!19: 00 117 80 76 3.10 2.6 11/24/86 11 : 1!11!1 119 80 76 3. Ql 2.6 11/241/86 13: 0t!l 121 8QI 75 3.0 2.5 11/24/86 15: 121!21 1"' ........ 79 75 2.9 2o5 11/24/86 1 7: 121!21 125 79 75 2.9 .., c:' ..... ...J 11/24/86 1 9: f!lftJ 127 79 75 2.9 ,..., o:= .£.u 11/24/86 21 : !21!...1 129 78 75 2.8 2.5 11/24/86 23: f!l!Zl 131 78 75 2.8 ,., c-4•W DAILY AVERAGE VALUES 3. 121 2.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH Q,.:.'iTE TIME ..... _ .. ______ -----___ .. _____ ------ l1 /25/86 !211.: j~iQJ 11125/86 QJ3:t-!HZI l.1 /25/86 Ql5: !ZlQl 11 /25/86 1~17: !21!21 11/25/86 lc!l9:1!1!21 11125/86 11: 1!11!1 11/25/86 1.3:12lS.1l 11125/86 15: !!il!l 11/25/86 17: Y.l0 11125/86 19:01!1 11 /2~)/86 21: ~!li!l 11/25/86 23: IlliZI 11/26/86 01: fZ)Ql 11 I 26 I 86 Y.l3: i!lill 11 /2 6/86 1!15 : i:ZlY.I 11/26/86 1217:00 11/26186 1219: !Zl!ZI 1. 1/26/86 11: V.i0 11126186 13: !210 11/26186 15:1!10 11126/86 17: {!1!21 11/26/86 19: ic!H21 11126/86 21: !Zl!ZI 11/26186 23:00 11 /27/86 !?.H: 01!1 11/27/86 1!13:!211!1 11/27/86 ~:15: QlfZl 11 127/86 1217: !ZIY.l 11./2~7 186 1Zl9: 00 11 I 2 7 I 86 1 1 : !!lQI 1. 1 / 2 7/ 86 13 : 1210 11127/86 15:Y.I!ZI 11127/86 17:¥-10 1.1127/86 19: 1!1121 '11/27186 21:Y.It:s 11/27/86 2:3: 1!>!!1 BYTE RA~Il DATA ========== 133 78 75 135 78 75 137 78 75 139 78 75 141 78 75 143 78 75 145 78 74 147 78 74 149 78 74 151 78 74 153 77 74 155 77 74 DAILY AVERAGE VALUES 157 77 74 159 '77 73 161 77 73 163 "16 73 165 76 73 167 76 73 169 76 73 171 76 73 173 76 72 175 76 72 177 76 72 179 76 72 DAILY AVERAGE VALUES 181 75 72 183 76 72 185 76 72 187 76 72 189 76 72 191 75 72 193 75 71 195 75 72 197 75 71 199 75 71 2(.11 75 71 21!!3 7 4 71cl DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.7 2.7 2.8 2.7 2.7 2.7 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.~ 2.6 2.6 2.6 2.6 2.6 2.5 2.5 2.5 2.5 2.5 2.5 2.4 2.5 DATA FILE : RIFFLE0b START: 11/19/86 13:00 STOF': 12/1!2!/86 11~15 CHf4N 2 DEG C. ------------ 2.5 ,..., .,. ..:: • ..J 2.5 2.5 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 ..., "::" ..:... . .._, 2.3 ,., ~ ...:.. " ._, 2.3 2.3 .,.., *':!' ..:... . ._. 2.2 2.2 2.2 .., -::' ..:.... ·-· 2.2 ..., ..., ..:..."""' 2.2 2.2 ,., .., ..... "'- 2.2 2. 1 2. 1 2.1 2. !Zl .., .., .:.. ..... ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-29~~86 DATA FILE : R IFFLElZl6 BRADLEY LAKE HYDRO PROJECT START: 11/19/86 13: IZH2l BRADLEY RIVER -RIFFLE REACH STOP: 12/ Hl/86 11: 15 CHAN 1 CHAN 2 DATE TII"1E BYTE RAW DATA DEG c. DEG c. --------===== --------------------======= ------------------------ 11/28/86 QJ 1 : Qllil 2~!15 74 71!1 2.4 2. 1!1 11/28/86 !Z!3 : V.HZJ 2!!17 74 71!! 2.4 2. !21 11/28/86 1215 : IZS !li 209 74 712! 2.4 2. !{.! 11/28/86 QS7: 12112! 211 73 71!1 2.3 2.0 11/28/86 09: 0!!i 213 73 69 ,., ~ 4. If·-' 1.9 11/28/86 1 1 : !!ll!l 215 73 69 2.3 1.9 11/28/86 13: ~!10 217 7.,.. ... , 69 2.3 1.9 11/28/86 15: l2l0 219 7-:o: ..... 69 2.3 1.9 11/28/86 17:00 221 73 69 2.3 1. 9 11/28/86 1 9: 1210 223 73 68 ..., ~ 4. • ._, 1.8 11/28/86 21 : 1210 225 72 68 2.2 1.8 11/28/86 23: Y.li!l 227 73 68 '? ~ ..... "'". 1.8 DAILY AVERAGE VALUES 2.3 1.9 11/29/86 121 1 : 121!21 229 72 68 2.2 1. 8 11/29/86 03: 012> 231 7-:o: ..... 68 #""j ""::"' 4. • .._, 1.8 11/29/86 1215 : 121 IZI "':\~"":!" ~ .... .._. 72 68 2.2 1.8 11/29/86 ~?7: 00 235 72 68 '"') '"') ......... 1.8 11/29/86 1219: 0Q! 237 72 67 2.2 1.7 11/29/86 11 : 012i 239 72 67 2.2 1.7 11/29/86 1 ~5: rll!!l 241 71 67 2. 1 1.7 11/29/86 15: QI!ZS 243 71 67 2.1 1.7 11/29/86 17:00 245 71 67 2. 1 1.7 11/29/86 19: 1210 247 72 68 2.2 1.8 11/29/86 21 : l!lrll 249 72 68 2.2 1.8 11./29/86 23:00 251. 7.,... ... , 68 2.3 1.8 DAILY AVERAGE VALUES 2.2 1.8 11 /3!21/86 J!S 1 : 0~!1 253 72 68 2.2 1. 8 11 FSJ!I/86 1!13: 0f!l 255 72 68 2.2 1.8 11 /3~::1/86 05: 121.0 257 72 67 2.2 1.7 .11/30/86 !2f7 : !Zl ~!l 259 72 67 2.2 1.7 11/312i/86 1219 : JZ! 121 261 72 67 2.2 1.7 11 /31ZI/86 11 : !!10 263 72 67 '"') '? ......... 1.7 11 /3l!i/86 13: 01!i 265 71 67 2.1 1.7 11 /3J!l/86 15: 1211!1 267 71 67 2. 1 1.7 11/3121/86 17: 01!5 269 71 67 2. 1 1.7 11/::;W/86 19: !lll!l 271 72 67 2.2 1.7 11/3t!!/86 21: J{.it.!l 273 71 67 2.1 1.7 1. 1 /3Ql/86 23: lll!Zl 275 71 67 2.1 1.7 Dl=i!LY AVERAGE VALUES lj """;I "' ..... 1.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE T II'1E -------------------------- 12./!Zi 1 I 86 so 1; f?lf.l 12/1211186 1.!13: !MI 12/1211/86 1!15:00 12/~!11186 07: lll0 12/ Ill 1 I 86 1..'19: 1210 12/!!ll/86 11:1!1121 12/QI 1/86 13: 0f21 12/!!11186 15:0!!1 12/1211/8617:00 1211o 1/86 19: 1o121 12 / !!l 1 I 86 21 : 0f2l 1211211 186 23: mt?l 12/~!12/86 1211:00 12/02/86 QJ3: ~!@ 12/1!!2/86 Q15: 0!ll 12/1212/86 07:00 12/lo2/86 09: fZH!I 12/02186 11:00 12/~!12186 13:1ll£!1 12/i-92186 15: 0Ql 12/!2121 86 17: 0!Zl 1.2/02/86 19:1lllll 12/Ql2/86 21:00 12/QI2/86 23: 1!1!21 12/1213/86 01:00 12./!?.1:::;;/86 IZ13: QIIZI 121Q13/86 Jll5: 0125 12 I !!13/86 07: 1!1121 12/~~i3186 09: r21121 12/1213/86 11:00 12/QI3/86 13:00 12d?I:.V86 15:1ZHZI 12/0::!./86 17:Y.H!I 12/1!13/86 19:1!1121 12/~21~.5/86 21.: l!H:l 12/1213/86 23: 121121 BYTE 2T7 279 281 283 285 287 289 291 293 295 297 RAW DATA -------------------- 71 67 71 67 70 66 70 66 7!Zl 66 712! 65 69 65 68 64 68 64 69 65 70 65 299 71!1 66 DAILY AVERAGE VALUES 301 71.!1 66 303 70 66 31!15 69 65 307 69 65 3Y.i9 7 (il 66 311 70 66 313 71!1 66 315 69 66 317 69 65 319 69 65 321 7f!i 66 323 71 67 DAILY AVERAGE VALUES :525 7121 67 327 71 67 329 70 67 331 70 66 333 7{21 67 335 71 67 337 71 67 339 71 67 341 7121 66 343 71!1 66 :345 71 67 347 71 67 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 2.1 2. 1 2.0 2. Ill 2.0 2. 1!1 1. 9 1.8 1. 8 1.9 2.0 2. 121 2. f!l 2. 121 2.0 1.9 1.9 2. 121 2. 121 2.0 1.9 1.9 1.9 2.0 2. ~ 2. 121 2.0 2.1 2.0 2. Ill 2. IZI 2. 1 2.1 2. 1 2. I(} 2. 121 2.1 2.1 2. 1 DATA FILE : RIFFLE06 START: 11/19/86 13:00 STOP: 12/11!1/86 11: 15 CHAN 2 DEG c. ------------ 1.7 1.7 1.6 1.6 1. 6 1.5 1. 5 1.4 1.4 1.5 1.5 1.6 1. 6 1.6 1.6 1.5 1.5 1.6 1.6 1.6 1.6 1.5 1.5 1.6 1.7 1.6 1.7 1.7 1.7 1.6 1.7 1.7 1.7 1.7 1.6 1.6 1.7 1. 7 1.7' ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DAlA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-29~86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH Df.HE TIME ---·----------·---------------- 12/!!14/86 01:0Ql 12/1!.14/86 '-il3: 1!10 12/1!14/86 Y.15! ~!!QS 12.dil4 /86 !217: IZli!i t2n~l4/86 ~c.~9: Qlll! 12/!!14/86 11: 1!1(21 1.2/~~14/86 13: ~!I!ZI 12/!!14/86 15: 1211!1 12/ ~~>4 /Sa , ; "·:~~~, 1 2 /Ill 'i· i b .::. ... 7 ; ~!11!1 l .;., ~;lit/ d6 21 ~ ;~ .. ,;_; 1 ~:. / ~.!i !:,:; / {j 0 ~:::i : '!i ,z, 1 :~/i;~i5/ 86 I!J7: Qll2l 12 / !f.!::'j i 86 !219: fJfl :t2./JZJ5; ;3\~ 11 ~~~};a l 2 / i~l ~.:,l / t-J <'!::• l ,.:;, ~ ~·L :.;) ; . .::/ (J.:;;; 8.-':, 1:3;: Q!0 ' ~-/ ):''·:.J /db 15: 121QI 12/9.16/86 17: ll.IQI 12/!!16/86 19:121121 12/1!!6/86 21:01!1 12/1~16/Bb 23: QIQI BYTE RAW DATA ------------------------ 349 71 67 351 71 67 "":'' C" "":" . ..),...),.;• 71 67 ...... c:: c::" .::.-.~-.~ 71 67 "':"C.'"""1" ._\,_1 I 71 67 359 71 67 361 . ., . ' J. :::;.(:.>._ ; 1 6/ ::::o~5 71 67 :..:;67 71 i..7 ~.-• I 369 71 6 ~7 ::; I I 7 1 6'/ J. DAILY AVERAGE VALUES ··:~ 7·-:r ·-'I •-' 7 1 6'1' .. :t'}C.:; • .:,1 I '-J 7 1 6"7 3"'/'7 7 1 67 ~37S· 71 67 38 •I ... , ., 6 ···r J. I ... / :::.c):~s .. , 1 67 I "~· .-;;.;..::.: ·-•u,J i I 1 67 3t5'7 "'/' 1 0 ..• I l :·.r:B·:;. 7 1 67 ~~:· .. ~,: 1. '"";·' 1 67 I :::::92~ ~7 1 6"' l ~..SS1 5 .. , i 7' I ... \.:) LfQ.i5 7!!1 67 i.j.j)} 71Zl 6 7 41219 71 67 411 71 67 413 71 67 415 71 67 417 71 67 419 71 67 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 2. 1 2. 1 2.1 ·.· .... . - ..;;. • 1 2. 1 2. 1 2. l 2. 1. 2. 1 'j t ...:... • .J. :2. l 2. 1 ,.,. ~: 4. J. 2. 1 2. 1 2. 1 2. 1 ..:. " 1 :;;: • 1 2. 1 2. Ill 2. 121 2. 1 2. 1 2. 1 2. 1 2. 1. 2. 1 2. 1 DATA FILE : RIFFLE06 START: 11/19/86 13:~l!i!! STOP: 12/ U2l/86 11: 15 CHAN 2 DEG C. ------------ 1.7 .l •. L l • '/ 1.7 1.1 L/ L7 1.7 1. ,. L/ ·, "i J," I .;.. "' / .i. • I I ~· .J. Ill .• j_ H .. / i. '7 1 ' • i 1 ·-r o I ; -, .&. • I ' ·-·· .t • ! .i. ... · 1 .... l. / 1. 7 1. 7 1.7 1. 7 1.7 1. 7 1.7 1.7 1.7 1.7 1.7 1..7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-29-·86 DATA FILE . RIFFLEl2l6 . BRADLEY LAI<E HYDF<O PROJECT START: 11/19/86 13: 0Q! BRt-O.DLEY RIVER -F\IFFLE REACH STOP: 12/ lQl/86 1l. : 15 CHAN 1 CHAN ., .... Dt-HE TIME BYTE RAW DATA DEG c. DEG c. -·------·-===== ----========== ====== ---·---·--------------- 12/Ql7/86 i!i 1 : lZil!l 4·21 71 67 2. 1 1.7 12/1!17 /86 !21 :3; : Ql Qi 423 71 67 2. 1 1.7 12/W7 /86 Qi5: 1!1!21 425 71 67 2. 1 1.7 12/1!17 /86 1!17: 1~1!1 427 71 68 2. 1 1.8 12n:!?/86 i!19 : (il Y.l 429 71 67 2. 1 1.7 12/1!17/86 11 : !Zl!!l 431 71 67 2. 1 1.7 12/Y.rt /86 1 ~5: IlliZI 433 71 67 2.1 1.7 12/!217 /86 15: l!l!ZI 4..,.1: . .;. . ._; 71 67 2. 1 1.7 12/l2l7 /86 17: 0!!> 437 71 67 2.1 1.7 12/1217/86 19: 0121 4:39 71 67 2.1 1.7 12/1!17 /86 21 : IZI!Zl 441 71 67 2.1 1.7 12/i217 /86 23: 121121 443 71 67 2.1 1.7 DAILY AVERAGE VALUES 2.1 1.7 12/1218/86 1!11 : !21 fZI 445 71Zl 67 2. 121 1.7 12/08/86 $.!13: 0Ql 447 71 67 2.1 1.7 12/1!18/86 1215: IZI!!i 449 7l!S 67 2.0 1.7 12/1!18/86 1217:00 451 7!21 67 2.0 1.7 12/1218/86 !219: I!H!i 453 7!21 67 2.0 1.7 12/1218/86 1 1. : 12H2i 455 7QI 67 2.0 1.7 12/1!18/86 13: !21!21 457 71!i 67 2.0 1.7 12/1218/86 15: !2!121 459 7V.i 67 2.0 1. 7 12/(18/86 1 7 : !ZI!ZI 461 70 67 2.0 1 -r a I 12/1.~8/86 19: 1o!Zi 463 7es 67 2.0 1.7 12/1218/86 21 : 1o12s 465 70 67 2.0 1.7 12/fZIS/86 2:5: 121121 467 70 67 2.0 1.7 DAILY AVERAGE VALUES 2. 121 1.7 12/1219/86 1!11 : l.iJ !!I 469 71 67 2.1 1.7 12/1219/86 1!13: IZH21 471 71 67 2.1 1.7 l2/fil9/86 f!l5: 0!!1 473 71 67 2.1 1..7 12/1,:19/86 1217: !3!21 475 71 67 2.1 1.7 12/ !Zl9/86 1219: !Zl!!l 477 71 67 2.1 1.7 12/1!19/86 11 : Y.l!21 479 71 67 2.1 1.7 12/!Z19/86 13: Jll!ll 481 71 68 2.1 1.8 12/1?.19 /86 15: Qll!l 483 71 67 2.1 1.7 12/(!19/86 17:00 485 71 68 2.1 1. 8 12/$219/86 19: lli!Zl 487 71 68 2.1 1.8 12/1!19 /86 21: 0121 489 71 68 2.1 1.8 12/l~9 /86 2::: l?@ 4'-11 71 68 2.1 1.8 DAILY AVERAGE VALUES 2.1 1.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-29-86 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -RIFFLE REACH DATE TIME BYTE RAW DATA --------------------------------------------------- 12/1 Ql/86 Ql1 : 0i~l 493 71 68 12/ Hl/86 ~!l :::;; : l!llZl 495 71 68 12/ ll!l/86 1!.!5: 00 497 71 68 12/ 1 1!1/86 fil7: 012! 499 71 68 12/ H?/86 !!!9: Ql0 501 71 68 12/lY.I/86 11 : lZIQ! 5lif3 71 68 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 2. 1 2. 1 2. 1 2. 1 2.1 2. 1 2.1 DATA FILE : RIFFLE06 START: 11/19/86 13:00 STOP: 12/10/86 11:15 CHAN 2 DEG C. ------------· 1.8 1.8 1.8 1.8 1.8 1.8 1.8 ATTACHMENT II TREE BAR REACH ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-!!12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 BEGIN OBS :Begin EI'~D OBS End DATA BOOK MISSING -WILL CHECK FOR IT SAME AS BEGIN DATE DP,TE TIME ·-------------------------- f:i2/ 14/86 13: 121!21 !Z12/ 14/86 15: !!H!I ~!12/14/86 17:00 1!12/14/86 19:121~1 !212/14 /86 21: IZH2l 02/14/86 23: {!1!21 !212 I 15/86 !211 : 121!!1 !!!2/15/86 !!13! lillll !!12/ 15/86 !215: IZll.!i Y.l2/ 15i86 Ql7 :Lil0 !!12/15/86 09:!211Zl !212/ 15/86 11: 0Ql 1212/15/86 13:!21121 1212/15/86 15:1.!10 !!12/15/86 17:!21!!1 1212/15/86 19:00 fll2/ 15/86 21: IZIIZI !212/ 15/86 23: !Zl!ll !212/16/86 !211: 1211!1 12l2/16/86 1213: !.!>Ill l2l2/ 16/86 Ql5: 0Ql !!l2/16/86 1!>7:€il2i 1212/16/86 ~~19: 00 02/16/86 11: 1!10 !212/ 16/86 13: 1211.!1 ill2 / 16/8 6 1 !:i: IllY.! !!12/16/86 17:1ZI!!.l C!l2/ 1. 6/86 19: !211!1 !Il2/1,S/86 21.:~11!1 ~~12/16/86 23: Y.H,~l BYTE RAW DATA --------------------l 112 52 3 11~! 55 5 110 56 7 1~!i6 54 9 102 52 11 99 51 DAILY AVERAGE VALUES 15 17 19 21 98 50 96 50 95 50 94 50 93 5t!1 93 50 25 93 51!1 27 93 52 29 93 54 31 92 52 33 9~1 51 35 89 50 DAILY AVERAGE VALUES 37 a·7 49 39 86 49 41 84 49 4:3 77 49 45 72 49 47 69 49 49 67 50 51 67 51 53 69 53 55 69 52 57 69 51 59 68 50 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.2 6. !Zl 6.0 5.6 5.2 4.9 5.7 4.8 4.6 4.5 4.4 4.3 4.3 4.3 4.3 4.3 4.2 4. l!l 3.9 4.3 3.7 3.6 3.4 2.7 ,., . ., "-. "- 1.9 1.7 1.7 1.9 1.9 1. 9 1.8 2.4 CHAN 2 DEG C. ====== J!~. 2 l!l. 5 Ql. 6 0.4 ~~. 2 1!1. 1 0.3 121 • 121 Qi. 121 0. !!l 0.0 0.0 Ill • 121 !!l. t!1 0.2 0.4 Ill. 2 Ill. 1 0.121 1!1. 1 -0.1 -0.1 -121. 1 -!!1. 1 -Ill. 1 -es. 1 0.121 121. 1 12!. 3 !!l. 2 !ll. 1 !21. 0 !21. Y.l ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-~1.1 DEG C TEMP/TEMP RECORDER Page 2 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ---·-------~---___ .. _____ ----- 1212/ 1 7/86 Q11: !211..:1 ~12 I 17/86 ~13: l!H!I IZ12/1 7 I 86 Y.l5: 121!21 !2i21 17/86 1217: 12!121 !212 I 1 7/ 86 lll9: !21121 1!12/ 17./86 11:00 1212117/86 13: fZl0 1212/17/86 15: 1!1121 fll2/17/86 l7:f1.1!21 1212/17/86 19:121121 ~:l2/17/86 21:£1121 !!12/ 17/86 23: 121121 1212 I 18/86 !211 : 1!1~~~ 02/18/136 03:121121 02/18/86 !215: Qll!J !!12/18/86 k:i7:00 !32/ 18/86 Ql9: !ZIQI !.!!21 18/86 11: IZH!l !l12/18/86 13:0121 Ql2/18/86 15:fZIJZI k12/18186 17:fli!ZI 02/18186 19:0!;:1 ,~12/ 18/86 21: !Zil21 1212/18/86 23: 1!.!~1 !212/ 19/86 12l1: 00 1212 I 1 9 I 86 03: !21121 i212 / 1 9 I 86 !215: ~<.'1121 1!12 I 1 9 I 86 07: 0121 1!12 I 1 9 I 86 1.':19: 1!10 1212/ 1 9/86 11: 1210 i-212119/86 13:1211Zi !ll2/19/86 15:121121 Ql2 / 1 '.:;l/86 17: 012! 1;;12.1 19/86 19: !Zil!l Ql2119186 21:1!1121 f.l21 19/86 23: !!liZ! BYTE RAW DATA ========== 61 67 49 63 67 49 65 67 49 67 66 49 69 66 49 71 65 49 73 64 49 75 64 5121 77 65 51 79 65 5121 81 64 49 83 64 49 DAILY AVERAGE VALUES 85 64 49 87 63 49 89 63 49 91 62 49 93 62 49 95 64 49 97 64 49 99 64 49 1!211 64 49 103 64 49 Hl5 64 49 1k!l7 64 49 DAILY AVERAGE VALUES 109 54 49 111 51 50 113 5121 50 115 50 49 117 50 49 119 50 49 121 50 49 123 51 49 125 52 49 127 52 49 129 51 49 131 51 50 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 1.7 1.7 1.7 1.6 1.6 1.5 1.4 1.4 1.5 1.5 1.4 1.4 1.5 1.4 1 .. 3 1. 3 1.2 1.2 1.4 1.4 1.4 1.4 1. 4 1.4. L4 1.3 121. 4 0.1 0.0 0. 1!1 0. Ql k1. 0 0.0 Ill. 1 121. 2 l!j. 2 l!i. 1 1!1. 1 1c1. 1 DATA FILE : TREBAR01 START: 02/14186 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ------------ -!21. 1 -1!1. 1 -!!1. 1 -Ill. 1 -1!1. 1 -0.1 -0.1 0. 121 0. 1 0.0 -0.1 -0.1 -0.1 -0. 1 -121. 1 -0.1 -!21. 1 -0.1 -121. 1 -0.1 -0.1 -0.1 -0.1 -0.1 -0.1 -0. 1 -121. 1 0.0 12•. 0 -0.1 -0.1 -0.1 -0.1 -1!1. 1 -121. 1 -!!1. 1 -QI. 1 IZI. 0 -Ill. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page :.::; 12-1212~87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 1212/2~!1/86 lH: 0f21 f!i2/2~!5/86 lll3: 00 Ql2/2l{5/86 05: 1!1121 QI2/2QI/86 1!17: ~!IQI f!l2/2fll/86 1219; V.i!!i 1212/2!21/86 11: QHll 02/20/86 1 ::.;;.: 19121 !!12/20/86 15: QH!I !212/20/86 17:00 t!l2/2~1!86 19:0121 1!12/20/86 21: 1!10 Y-12/21!1/86 23:011.1 !Zl2/21/86 1.!11: 1210 Ql2/21 /86 03: !210 1?.12/21/86 05: Q!0 ~!12/ 21/86 !217: 0t21 ~?.12/21 /86 !219: 0QI !!12/21 /86 11: 1211!1 1!12/21/86 13:!!1QI k!12/21/86 15: 1!11!1 V.12 /21 I 86 1 7 : 1210 ~!12/21/86 19:~~0 1212/21/86 21:1!10 !!12/21 /86 Z5: !ZI0 1212/22/86 !?11: f!!Ql 1Zi2/22/86 QS:3: Y.i0 ~32/22/86 !1.15: 01ll 1212/22/86 1217: 01!1 1212/22/86 !!19: 1!1!21 1!12/22/86 11: l!llZI !212/22/86 13: l~ll!l Qi2/22/86 15: liiQI !ZI2/22 /86 17: 00 1?.12/22/86 19: 1!10 1!52/22/86 21: l!lY.> !?.i2/22/86 23: 1!10 BYTE RAW DATA -------------------- 133 51 5121 135 512J 49 137 51!1 49 139 51 49 141 52 49 143 52 49 145 53 49 147 54 49 149 55 49 151 56 49 153 57 5!ZI 155 57 49 DAILY AVERAGE VALUES 157 57 49 159 57 49 161 57 49 163 58 49 165 58 49 167 58 49 169 59 49 171 59 49 173 59 49 175 59 49 177 60 49 179 60 50 DAILY AVERAGE VALUES 181 60 49 183 60 49 185 61 49 187 62 5121 18'?' 62 49 191 63 49 193 64 49 195 65 49 197 6~1 49 199 67 51~ 21211 68 49 2S!)3 69 49 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== ~1. 1 e1. ~~ 0. 121 J!l. 1 ~:1. 2 121. 2 0.3 121. 4 Ill. 5 121. 6 0.7 0.7 0.3 121. 7 0.7 121. 7 121.8 0.8 0.8 fZJ.9 0.9 0.9 121. 9 Lra 1. 0 {21. 8 1. 0 1. 121 1.1 1.2 1.2 1. 3 1.4 1.5 1. 5 1.7 1. 8 1.9 1 .. 4 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ====== Ql. i(l -1!1. 1 -121. 1 -121. 1 -~!l. 1 -121. 1 -~i. 1 -0.1 -rll. 1 -0. 1 -11.1. 1 -0. 1 -0.1 -121. 1 -0.1 -0.1 -0.1 -~1. 1 -0p1 -0.1 -0.1 -0.1 -0.1 0.0 -~!1. 1 -u1. 1 -0. 1 -l!l. 1 0.0 -121. 1 -!Zl. 1 -Ill. 1 -0. 1 -V.I. 1 Ql. 0 -!21. 1 -0.1 -0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- !!12/23/86 !2!1: 1210 02/23/86 1!13: !!H21 ~~!2/23/86 1!15: 00 1212/23/86 1217:0121 ~!12/23/86 09: t!S0 02/23/86 11: 01!1 1!12/23/86 13:00 1212/23/86 15: t!l0 !212/23/86 17: Ql0 !212/23/86 19: 00 02/23/86 21:00 !212/23/86 23: 0121 12!2/24/86 1211: !21121 !212/24/86 03: 00 !~12/24/86 !215: 0121 !212/24/86 !217: s!S0 1212/24/86 !219:(.!1!21 ~1S2/24/86 11:1::10 !212/24/86 13: !21121 (212/24/86 15: 0!!S tf.l2/24/86 17: !2Hll Ql2/24/86 19: 121!!1 02/24/86 21: 0121 !-32/24/86 23: IllY.! !212/25/86 !211:!!10 02/25/86 !213: !!IUS 1212/25/86 05: 0!21 !212/25/86 07: fZif2l 1!12/25/ 86 09: f!l0 !212/25/86 11:1!l!ll 1212/25/86 13:00 1212/25/86 15: 0t;:l 02/25/86 17:!!10 !212/25/86 19: !21121 Y.J2/25/86 21: !210 1212/25/86 23: 121!21 BYTE RAW DATA -------------------- 2!215 7121 50 207 72 49 209 73 49 211 75 49 213 77 49 215 81'21 49 217 81 49 219 83 49 221 93 49 223 95 49 225 94 49 227 94 49 DAILY AVERAGE VALUES 229 231 233 235 237 239 241 243 245 247 249 90 49 87 49 85 5(!1 83 49 82 49 82 50 81 49 82 49 82 5121 82 49 82 49 251 83 50 DAILY AVERAGE VALUES 253 255 257 259 261 263 265 267 269 271 273 82 50 80 5121 80 49 81 49 84 49 85 49 86 50 85 49 85 5121 85 49 85 49 275 84 49 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 2.0 ""l ""l "-. "- ""l -..... ..) 2.5 2.7 3 .Ill 3.1 3c3 4.3 4.5 4.4 4.4 3.2 4.0 3.7 ..,.. c: ,_\ . ;.;} 3.3 3.2 3. 1 3.2 3.2 3.2 3.4 3.3 3.3 3.ili 3.0 3.1 3.4 3.5 3.6 3.5 3.5 3.5 3.4 3.4 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. -----·------- lZI. k.l -0.1 -Ill. 1 -0.1 -0.1 -0.1 -121. 1 -0.1 -121. 1 -Ill. 1 -0.1 -121. 1 -0.1 -0.1 -0 .. 1 0.0 -!21. 1 -0.1 V.I. f21 -0.1 -121. 1 1!1. 0 -0.1 -121. 1 ~~ • !21 -0.1 0. 121 0.0 -0.1 -Y.l. 1 -0.1 -k1. 1 0.0 -0.1 0. IZI -Ill. 1 -Ill. 1 -0. 1 -1!1. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-1212-87 DATA FILE : TREBARI211 BRADLEY LAJ<E HYDRO PROJECT STAF\T: 02/14/86 13: !21121 BRADLEY RIVER -TREE BAR REACH STOP: !.1>4 I !liB I 86 15:33 CHAN 1 CHAN ....... .L. DATE TIME BYTE RAW DATA DEG c. DEG c. ======== _.,. ____ ------------.. --====== ====== ---------------~:1:2/26/86 Qll: ~10 ~)1"7 ... , ·' 84 49 3.4 -121. 1 ~12/26/86 1!13: 0J!! 279 84 49 3.4 -0.1 1212/26/86 05: !210 281 84 49 3.4 -0.1 Ql2/2t!-J/86 Q17: 0!!1 283 84 50 3.4 ill • 1!1 02/26/86 1!19: !ll0 285 84 50 3.,4 121 • !21 1212/26/86 1 1 : ~!liZ! 287 84 49 3.4 -0.1 !212/26/86 13: 1210 289 84 49 3.4 -0.1 1212/26/86 15: !ZIQI 291 84 49 3.4 -0.1 1212/26/86 1 7: !lll!l 293 84 49 3.4 -1!1. 1 fli2/26/86 19: Ql0 295 85 49 ..,.. C" _ ... i..J -IZl. 1 1212/26/86 21 ! i21Y.I 297 83 49 "':-" -:r ._\. _ .. -121. 1 !ZS2/26/86 23: !Zj~2~ 299 81 50 3.1 0. Ql DAILY AVERAGE VALUES 3.4 -0.·1 !CI2/27 /86 !21 1 : 01!1 301 77 49 2.7 -!21. 1 1!12/27 /86 1213:00 303 77 50 2.7 !21. lZI !212/27 /86 1215:0121 305 76 5121 2.6 12!. 0 £12/27/86 07:00 307 77 50 2.7 l!l. 0 02/27/86 1219: !211ZI 309 77 512! 2.7 Ql • 121 1!12/2"7 /86 11!00 311 77 49 2.7 -121. 1 1!12/27/86 13: 1!1121 313 76 49 2.6 -lZI. 1 lr!l2/27/86 15:00 315 75 49 ,., c::' ..... ...J -0.1 (12/27/86 17: 0I!I 317 75 49 2.5 -~1. 1 !::12/27/86 19: 0t21 319 1!218 49 5.8 -121. 1 02/27/86 21 : !ZiiZI 321 1HI 49 6.0 -1!1. 1 !212/27 /86 23: ~}ljl} 323 11!21 49 6. Qi -Ill. 1 DAILY AVERAGE VALUES 3.5 -1!1. 1 {!12/ 28/86 !l.i 1 : !llfi! 325 110 49 6.0 -l!i. l 02/28/96 !ll3: 0Qi 327' 110 49 6. QS -0.1 Y-12/28/86 !!l5: 00 329 111 49 6.1 -121. 1 Ql2/28/86 !217: QllZl 331 116 49 6.6 -!21. 1 1ZI2/28/86 !.!19 :.0!!1 ~"':'P...,.. .,;.._,._, 119 49 6.9 -Ill. 1 Qi2/28/86 1 l : Qllll ~..,.&::" ._\._"li-....~ 12121 49 7. Ql -!21. 1 1!12/28/86 1 ;::; : Y.iY.i 337 12!21 49 7 .lr!l -Qi. 1 !!l2/28/86 15: 1!1121 339 12!!1 49 7. Qi -Y.I. 1 ;!.12/28/86 17: 0!!1 ::>41 121 49 7.1 -Ill. 1 1212/28/86 1 9: l!l!ll 343 122 49. 7.2 -!21. 1 ~·l2/2f:3/86 21 : !ZJ~:1 345 123 49 "7 ..,. } . ·-' -~:1. 1 !~12/28/86 23: 1!1121 347 122 49 7.2 -!21. 1 DAlLY AVERAGE VALUES 6.8 -0.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page "' 12-02~87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- ~?13/!H /86 ~:11: Ql~l QS3 / f!ll I 86 l!i3: 121121 lll::::;t~H /86 !!15: 00 ~!13 I Qi 1 /86 1!17: f!h2l ~!1::':\/!cH/86 1!19:QI!ZI Y.l3/QI1/86 11: 121J!l 12131!.!!1/86 13:00 121::;; I 1?11/86 15: 1!10 Q13/l!l1 /86 17: !210 f21~5/!Zl1/86 19:1!H!I 1213/101/86 21:00 Ql3 I !!ll/86 23: 01!1 ~213/1!12/86 !211: 1210 Y.l3/l!l2/86 03: l?.l~!l 0:3/!!12/86 05: @!l QI3/Q!2/86 !217:1210 1!13/!212/86 !!1'-T: 01!1 1!13/1!12/86 11:00 1!13/02/86 13: @121 !213/l212/86 15: 00 03/02/86 17:0121 1213/02/86 19:0121 0::;/!~12/86 21: !ZII21 ~~13/02/86 23: 0(!1 03/03/86 01: 1211!1 !ll3/!ll3/86 1!13: QIQI 1213/03/86 !!15: 1210 rll3/!!f3/86 07: I!S0 ~~3/03/86 ~.'!19: 1!10 !!13/!!13/86 11 : 1!1121 ~::131!213/86 13:00 03/03/86 15: QllZI !213/1;:13/86 17: l'lllll 1!13/!213/86 1.9:(!10 !213/Qi3/86 21: l!l!21 ~213/1!13/86 23: !211!1 BYTE RAW DATA ========== 349 120 49 351 115 512! 353 114 50 355 12!21 5121 357 120 49 359 115 49 361 111 49 363 107 49 365 U14 49 367 H2~2 49 369 101 49 371 11!1!21 50 DAILY AVERAGE VALUES 373 10~1 49 375 1!210 50 377 100 51!J 379 99 50 381 97 49 383 97 49 385 99 49 387 99 49 389 1!210 49 391 106 50 393 111 5!21 395 112 50 DAILY AVERAGE VALUES 397 112 49 399 111!1 51!1 401 U14 49 41213 100 49 405 97 49 41!17 11!15 49 41219 113 49 411 114 49 413 114 49 415 Hl9 50 417 101 50 419 96 49 DAILY AVERAGE VALUES CH?~N 1 DEG C. ------------ 7 .Ill 6.5 6.4 7. Ill 7. f!) 6.5 6.1 5.7 5.4 5.2 5.1 5. 121 6.1 5. 1!1 5. 121 5. t!l 4.9 4.7 4.7 4.9 4.9 5. 121 5.6 6.~ 6 .. 2 5.Z 6.2 6. 121 5.4 5.121 4.7 5.5 6.3 6.4 6.4 5.9 5.1 4.6 5.6 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ====== -121. 1 Ill • ill 0.0 0. t21 -Ill. 1 -!21. 1 -~1. 1 -0cl -0.1 -121. 1 -0.1 .Ill • 121 -1!1. 1 -121. 1 0.0 ~}. (11 121. 0 -0.1 -f21. 1 -121. 1 -0.1 -Y.I. 1 0,1ZI 0. 1!1 Y.l. 121 -!21. 1 -!21. 1 0.121 -0.1 -!21. 1 -1!1. 1 -0.1 -!21. 1 -Ill. 1 -121. 1 0.0 -u1. 1 -IZI. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-12!2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE T II'1E -----------------===== i;~l::. / Qi4/86 !1.11 ; Qlf!i 0~5/i!i4/86 ;213: Qlj(.l 0:.:::/u14/86 Ql5: !!i!ll J!i~T./1~4/86 !217: 1211!1 J.:l3/Ql4/86 !1.19: Y.I!Zi !!13 I !!14 I 86 1 1 : t2i!Zl ui;::::;Ql4/86 .1.3: lc!llZI 1213/!214/86 15:V.10 03/!214/86 :1.7: !21!21 !!5::;. I !214 I 86 1 9: Qls?.i Y.l~)/!214/86 21: 121121 Qr.:) / !!14 I 86 23: i!H'!.i 03/ Y-15 /86 !Zl 1 : 1!10 03/1215/86 Ql3: QI(!J SEI :3 h215/86 !!15: ~~~~ 03/Ql5/86 !217: 00 !.!53/ 1!15 I 86 !219: l!l!.ll lll3/!21~1/86 11: Ql0 IZI3/m5/86 13: 1!1!21 Ql3/!ll5/86 15:00 03/1!15/86 17: 0£!! 1?13/ 05/86 19: I?H!I !Zl~3 I t!l5/86 21 : QliZS 0:3/!!15/86 23: QIQI !213/!216/86 01:01!1 Ql3/li.l6/86 Ql3: f!S!~l !21~5/!!16/86 .. ;:15: 00 Ql3/tZl6/86 07: {!i0 ~l3/IZI6/86 !:!19: 00 121 :;. / !216/ H6 1 1 : Jt.l~~~ !21:./Qi6/86 13:01!! !?.!3/Qi6/86 15: Qlf2l Ql3/l~i6/86 17: 1!10 !113 / !216 I 86 1 9 : !2!0 1Zl3/i!16 /86 21 : !Zi~l !!13 / l!lo /86 23: !i.I!Zi BYTE RAW DATA ========== 421 95 49 423 99 49 425 114 49 427 115 50 429 117 49 431 119 49 433 120 49 435 121 51!1 437 121 49 439 121!1 49 441 119 51'.:1 443 119 49 DAILY AVERAGE 445 119 49 447 119 49 449 119 49 451 12fll 49 453 12121 49 455 120 49 457 12{21 49 459 120 49 461 12!2S 49 46:::\ 121 50 465 122 5S!l 467 124 49 VALUES DAILY AVERAGE VALUES 469 124 5!2! 471 124 49 473 124 49 475 124 49 4Tl 123 49 479 121 5QI 481 114 49 483 114 49 485 11.4 49 487 11::::; 51!1 489 113 5~3 491 113 49 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 4.5 4.9 6.4 6.5 6.7 6.9 7.0 7. 1 7.1 7. es 6.9 6.9 6.5 6.9 6.9 6.9 7.0 7. 121 7. 1!1 7. {21 7.0 7. 121 7.1 7.2 7.4 7.4 7.4 7.4 7.4 7.3 7. 1 6.4 6.4 6.4 6.3 6.3 6.3 6.8 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ------------ -!ZI. 1 -Qi. 1 -0.1 121. Ql -0.1 -0.1 -£1. 1 0.0 -121. 1 -121. 1 0. Ql -1!1. 1 -121. 1 -!21. 1 -121. 1 -1!1. 1 -0.1 -0.1 -0. 1 -0.1 -121. 1 -0.1 0. Ql Lil. 0 -121. 1 -1!1. 1 Ill. S!l -0.1 -fll. 1 -1!1. 1 -Ill. 1 0.0 -fll. 1 -QI. 1 -e1. 1 ill. Ill 0. Ill -1!1. 1 -121. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-02-8~ DATA FILE . TREBARfll1 . BRADLEY LAI<E HYDF<O PROJECT START: 1212/14/86 13: 01!1 BRADLEY RIVER -TREE BAR REACH STOP: lr!S4/Ql8/86 15:33 CHAN 1 CHAN " .<.. DATE TIME BYTE RAW DATA DEG c. DEG c. --·-----------==== ========== ------------------------------------- Ql3/lll7/86 QS1: ~:%1 493 113 5121 6.3 0.0 1!13/QI7/86 k:l3: 1!11:':1 495 113 49 6.3 -!!1. 1 1213/07/86 1!15: 121121 497 115 50 6.5 121. 0 I!J3/!!17 /86 lil7: f!SQI 499 117 50 6.7 121.0 1:~!3/1217/86 ~19: Q!QI 501 118 49 6.8 -!!I. 1 it13/!217 /86 l. 1 : 012) 5!!13 114 49 6.4 -0.1 03/1217/86 13:00 51215 113 49 6.3 -0.1 0::./IZI7 /86 15: !2)121 51ll7 112 50 6.2 0. 121 03/!217 /86 17: 0fll 509 110 49 6.0 -Ill. 1 03n:s7/86 1 ':Y : l!I!ZI 511 11!17 49 5.7 -e1. 1 it>3/i!17 /86 21:00 513 Hll 49 5.1 -Ill. 1 k~13/07/86 23: 1211!1 515 97 49 4.7 -0.1 DAILY AVERAGE VALUES 6.1 -QI. 1 03/1?>8/86 1!11 : Ql(.il 517 q-:r ..... 49 4.3 -!ll. 1 03/~<:18/86 .('13: 00 519 92 49 4.2 -0. 1 ~:1:3/lllS/86 fll5: 0~1 521 91 50 4. 1 0. fZl f213/!ZI8/86 07: Ql0 523 91 S!ZI 4.1 0.0 1!.13/1!18/86 !219: 01ll 525 92 49 4.2 -0.1 !213/1218/86 11: 0!ll 527 9121 49 4.0 -1<!1. 1 03/QI8/86 13: QIQI 529 96 49 4.6 -!ll. 1 03/08/86 15:00 531 H$4 49 5.4 -fi.l. 1 1!13/!!18/86 1 7: 1!1121 533 98 49 4.8 -0. 1 Y.i3/1218/86 19:00 535 96 49 4 .. 6 -0.1 1!13/ QIS/86 21:00 537 94 49 4.4 -0.1 li.i3/!l18/86 23: !l'l!l! 539 89 49 3.,9 -1(.1. 1 DAILY AVERAGE VALUES 4.4 -0.1 1213/1219/86 fll1 : f2lt.:!l 541 88 Sill 3.8 !21. 0 P-13/1!19/86 Q!3: fll!Zl 543 88 49 3.8 -0.1 03/l-!19/86 !215: 0!21 545 88 50 3.8 0.0 !213/1219/86 fll7:1i.l!ll 547 88 5121 3.8 IZI. kl (il3/il.l9/86 1219: !llfcil 549 88 49 3.8 -Ill. 1 ~213/!tl9/86 11 : l!lfll 551 91 49 4.1 -!ZI. 1 03/1219/86 1 :\: !210 553 93 49 4.3 -Ill. 1 1!.13/1219 /86 15: 0!21 555 93 49 4 ..,.. •'"" -0.1 03/1!19/86 17:00 557 93 49 4.3 -0.1 03/!!19/86 1 9: IZ!Ql 559 92 49 4.2 -Ill. 1 !ZI3/QI9/86 21 : J!lj(.l 561 92 49 4.2 -V.I. 1 !!13/1!19/86 23: !ll!!.J 563 92 49 4.2 -V.I. 1 DAILY AVERAGE VALUES 4.1 -!1.1. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 9 12-02~137 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------·-----------===== Ql::;,\ / 1121/86 1211 : fll~!l 121 :::;J 1!?.1/86 !213: f.!S~I 1!13/ 10186 1!15: 1::10 1!13/ Hi/86 1!17: !!H!l k:l:?;;l Hl/86 Ql·:t: QIY.l !2131 10/86 11: 121!21 03/Hl/86 13:0!!1 12131 11!1 I 86 15: IZHZI Ql:51 Hl186 17: IZII?i !li3/Hl/86 19:~11!1 !Zl31 H!/86 21: 1-!IQI 0~\/ Hll86 23: £l!~l 1213 I 11 /86 !211 : llHZl !213/ 11 186 !213: !21~!1 !213 I 11 I 86 !215: 1!1!21 1213/11/86 07: 1!1!21 !213 / 11 /86 1219: Ill!!! Ql3 / 11 /86 11 : 1210 03/11186 13: Qlll! ll13/11/86 15:!21!.'!1 ~!13111/86 17:1!11!1 1213/11186 19: 0!21 l2i31 11186 21: !!h!l !2131 11/86 23: !211!1 V.13 I 12/86 l!ll : 9.10 1!13 I 1 2/86 1213: !ll!ZI t331 12186 1!15: 01!1 03/12186 1217:0121 1213112/86 09:1210 !!13/12186 11:!210 !213/ 12/86 13: Qll!l !!1::;:;/ 12186 15: QIQI ~!13/12/E16 17:1o':ll!.";) 0::\112/86 19: Y.H!> 1-!13/1.2/86 21:121!!1 IZI3/ 12/86 23: !21!21 BYTE RAW DATA ========== 565 89 5f2l 567 88 49 569 88 49 571 88 49 573 88 49 575 90 49 577 94 49 579 93 5!21 581 92 49 583 ':t.1 50 585 88 49 587 88 51!1 DAILY AVERAGE VALUES 589 88 50 591 88 49 593 88 49 595 88 49 597 88 49 599 91 5t:l 6(!11 93 49 61213 94 50 605 94 50 607 94 5!l> 6!!19 94 50 611 94 50 DAILY AVERAGE VALUES 613 94 51!.1 615 94 50 617 93 50 619 93 50 621 94 50 623 94 50 625 94 50 627 95 5Y.! 629 93 50 631 93 5~!1 633 93 5t2S 635 92 51 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 3.9 3.8 3.8 3.8 3.8 4. ~~ 4.4 4.3 4.2 4. 1 3.8 3.8 4. Ill 3.8 3.8 3.8 3.8 3.8 4.1 4.3 4 .. 4 4.4 4.4 4.4 4.4 4.1 4.4 4.4 4.3 4.3 4.4 4.4 4.4 4.5 4.3 4.3 4.3 4 '? ..... 4.4 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOF': 04/08/86 15:33 CHAN 2 DEG C. ------------ !ZI. Ill -0.1 -Ill. 1 -12!. 1 -£1. 1 -!!S. 1 -121. 1 0. Y.l -!21. 1 0.0 -£1. 1 0. Y.l -0.1 0.0 -0.1 -0.1 -0.1 -121. 1 0.0 -0. 1 (11. 0 Y.l • Ql 121. fll 0. Y.l 0.0 -121. Ill 121. 0 Ql. 0 ~~. 121 0.0 £1.0 0. !?.1 121. 0 121. Ql Ill. ,~, 0.0 m. 121 !!1. 1 121. 0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page illS 12-02 .. ··87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ===== Q!3/ 13 I 86 1211: Ql!ZI ;.~s::;t~.:::/86 1213:121121 Ql:3/ :1.3/86 ~!l5: IZ!Q} 1Z1::.1 13/86 !Zi7: fliQ! ~zs:::/ 13/86 !219: 1!H~l !213/13/86 ll:il!!Zl Q!3/ 13/86 13: lc':l0 03/1~./86 15:1!)12! 1!13/13/86 17:f.?l0 12!3/13/86 19:Y.SQ! 03/13/86 21:012! Q!3/ 13 I 86 23: Y.il!! !213/14/86 Qll:I2SQI f{;:;:;; 14/86 Ql3: !Zll21 ~13/14/86 05: 0121 1213/14/86 !2!7:1llf2! 03/14/86 1.!19: slll!l Ql~:)/14/86 11:1!10 f:l3/14/96 13:0121 !213i 1.4/86 15: Y.HZI !!13/14/86 17: Y.ll21 1!13/ 14/86 19: 1210 1!13/14/86 21:Y.H!I !2!3/ 14/86 23: 0i~1 !21 :-!\ / 1 5/8 6 !211 : IZI!!l !213/15/86 ~r:~: tm2! 03/15/96 Q!5: ll!QI 03 I 15/St;, i217: Q!!ll 1213/15/86 09:121!21 !213/15/86 11:!210 03/15/86 13: 0!11 1?.13/15/86 15:0fll Ql3/15/86 17:00 ~.73/15/86 19: I!IQ! l.~!3/15/86 21:1Z!I21 !!53/ 15/86 23: (!SQ! BYTE RAW DATA ---------------·----- 637 89 5!2! 639 89 51 641 89 51 643 89 51 645 89 51 647 89 51 649 93 52 651 1QS2 52 653 11!12 51 655 99 51 657 97 51 659 96 51 DAILY AVERAGE VALUES 661 96 51 663 96 51 665 95 51 667 96 51!1 669 96 51 671. 98 51 673 11!13 52 675 101 52 677 100 52 679 97 51 681 96 51 68:~ 95 51 DAILY AVERAGE VALUES 685 94 51 687 94 51 689 94 51 691 95 52 693 95 52 695 96 53 697 96 54 699 96 53 7~11 96 53 71!13 95 5::::~ 7!lJ5 95 52 7t37 95 52 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 3.9 3.9 3.9 :3.9 3.9 3.9 4.3 5.2 5.2 4.9 4.7 4.6 4.4 4.5 4.6 4.6 4.8 5.3 5.1 5. Ql 4.7 4.~ 4.5 4.7 4 .. 4 4.4 4.4 4.5 4.5 4.6 4.6 4.6 4.6 4.5 4.5 4.5 4.5 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ------------- l2l. Ql l!i. 1 ~~~. 1 121. 1 !!1. 1 I!!. 1 0.2 121. 2 (4. 1 0. 1 1!1. 1 f!l. 1 121. 1 !!1. 1 0.1 0.1 121. 0 Qi. 1 121. 1 0.2 121. 2 0.2 0. 1 121. 1 121. 1 0. 1 121. 1 QS. 1 12!. 1 i2!. 2 !21. 2 0.3 ~1. 4 Y.S. 3 Ql. 3 {Zj. 3 0.2 0.2 !ll. 2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1l 12-12!2-~87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ----------------===== Y-13/16/86 !?il: 12l!!l !213/ 16/86 03: QSQI 12!3/ 16/86 !215: !21121 03/16/86 !217: !!1121 !213/ 16/86 tv9: f.!I!Zl 1!13/16/86 11: l!l!!l 03/16/86 13:1!JI2l 1!13/16/86 15:t!I!.ZI 03/16/86 17:QH!l 03/16/86 19: 121121 ~::13/16/86 21:0(25 12!3/16/86 23:12H?l Ql3 / 1 7/86 'ill : lll!!S £1:\/ 17/86 1213: Ill!!! Ql3 / 1 7/86 1215: !2!121 1!1:5/1.7/86 07:t!Hll Ql:3/ 17/86 1!19: 0121 9.13/17/86 11:01!.1 Ql3/17 /86 13: !2!(11 !213/ 17/86 15: lll'-!1 Y.1:5/ 17/86 17: I!H2l Ql3/17/86 19: V.>0 ~!!3/ 17/86 21: 0!!1 03/17/86 2::::0121 !2!3/18/86 !!il: 12H21 !!13/ 18/86 1213: 121121 03/18/86 05: LiiiZ! 0:::.\/ 18/86 1217: 01!1 ~!13 / 18/86 ~;!9: 0121 1!1::::; 18/86 11: lZ!Ql v.s::::./18/86 13:!!i0 ill3/18/86 15:QHZi QS3/18/86 17:V.H!S !~13/18/86 19:~MI i!'i3/18/86 21:~2>!~ !ll:;.\ / 18/86 z:::;: !2HZ! BYTE 7(19 711 RAW DATA ========== 96 98 c.-·· ...J..:..\ 52 713 99 52 715 98 52 717-98 53 719 98 54 721 99 54 723 99 55 725 98 55 727 98 55 729 98 55 731 98 55 DAILY AVERAGE 733 97 55 735 98 55 737 98 55 739 98 55 741 98 55 743 98 56 745 99 57 747 99 58 749 99 59 751 97 59 753 97 59 755 97 58 DAILY AVERAGE 757 759 761 763 765 767 769 771 773 775 777 779 96 57 96 56 95 55 95 55 95 55 95 55 95 56 96 57 97 59 99 6m 98 59 VALUES VALUES CHAN 1 DEG C. =====-= 4.6 4.8 4.9 4.8 4.8 4.8 4.9 4.9 4.8 4.8 4.8 4.8 4.8 4.7 4.8 4.8 4.8 4.8 4.8 4.9 4.9 4.9 4.7 4.1 4.7 4.8 4.6 4.6 4.5 4.5 4.5 4.5 4.5 4.6 4.7 ·t. 9 4.8 4.) 4.6 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ====== !21. 3 Ql. 2 1!1. 2 !Zl. 2 r.!l. 3 0.4 £1. 4 0.5 Ql. 5 Ql. 5 Q!. 5 Qi. 5 0.4 Ql. 5 Ql. 5 0.5 QJ. 5 0.5 0.6 0.7 121.8 0.9 Ill. 9 Ql. 9 121. 8 0.7 !21. 7 0.6 !21. 5 121. 5 Ql. 5 0.5 121. 6 J ,. >!l ALASI<A POWE~; {..;, • :-.UR 1 TY DATA REPORT FOR DAlAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER 12-02-8~ BFf.:;L;i_E'r U~;<E HYDr:\f:) F·F-:UL•EC"f bR0DL~i RIVER -i~EE BAR REACH DATE TJ.i·1E :.:.• •... ,; "i' i -;;:-·:· ~} :·, :J. ~ ~!J ~il kj) ·~:~ • 1 !~ /-E\t..' l 'w~~ ~ ~?j ~!} B'iT,;: -.. -~.i ' I ·-·.l. ~".' 4 ., 'f ·..;:::; ;;_jr,: I "' 9::; -;1J; ·:r ·~ ::; i::· ·:,i ") ~) ~ ; -~-~~ -'~1 .;:).~> ~~~ I .... :l ~n,i ~~; ;!) r::· ,, .. 1 j 1::-1 ·-' ~::.·-:· ._}.";. ,:.,-.r:; t.-'· .. ,} ::~t:: ·::.~ ''/ t!}::-.~:. .;c'" ~;~ ..i~-< J ••.•. ·1 ,~',.lERHGE VALUES '. ' .· <.H~. II.·":· : I'< ~-~ 1 ~: I ·::-.-A':5 97 51 .. I .. ~-·~~i ~~. ·~ ~j ~) 8~17 96 5121 •f.•· .. > ::lb Iii ~-s : t!S!!l 81!19 95 5Qi ~:13 I 2Ql /86 1217: 0121 811 95 50 12i5/2V.l/86 09: 01!1 813 96 50 I213/2Ql/86 1 1 : l!ll2l 815 93 51 (!1=$/21~1/86 13: ~lV.I 817 90 51 03/20/86 15:00 819 91 53 1!13/ 2!~j /86 17: ~1!21 821 92 54 1!13/20/86 19: 0f(.i 823 93 56 0:2.~/2Qi/86 21: Y.l0 825 94 56 03/2!ll/86 23: 121~!) 827 92 55 DAILY AVERAGE VALUES 03/21/86 Ql 1 : 1210 829 92 53 !213/21/86 12>3: 01!1 831 92 52 ~:13/21/86 !215: !lll2i 833 92 51 1213/21/86 ~17: f!ll21 835 91 51 !213/21 /86 Y.l9: 0!21 837 91 51 !!13/21 /86 1 1 : 121121 839 92 52 1213/21/86 13: 121~1 841 93 &::"..,.. .J-.) !213/21 /86 15: !2H!I 843 94 55 fll3/21 /86 17: 1..':10 845 95 58 fii3/21/EI6 1 9: l!ll21 847 97 6121 121:2:./21/86 21: ~!10 849 98 60 !Zl3/21/86 23: 1211!1 851 96 58 DAILY AVERAGE VALUES ::: .. ::;:::;,..;:;;;;;::::::;:::: 4.4 ,., II 4 f "'l' ..,. " · .. > . ..,. .. ' 4.8 4.5 4.7 4.6 4.5 4.5 4.6 4.3 4.0 4.1 4.2 4.3 4.~ 4.2 4.4 4.2 4.2 4.2 4. 1 4. 1 4.2 4.3 4.4 4.5 4.7 4.8 4.6 4.4 DATA FILE ; T~Eb~k0; START: 02114/Bo J3:. Lr·iH1'4 ..:. i:.::. b c.: • G.4 ,z; • :_. !!l. l ,£ ..... .;. !21. 8 1!1. 7 Y.l. 4 1!1. 3 fll. 1 11.1. 0 0 .!21 Y.l • {11 !21. 0 0.1 l!1. 1 0.3 121. 4 0.6 !21. 6 ~~. 5 1!1. 2 I'll. 1 0.1 121. l 0.2 !21. 3 l!i. 5 I'll. 8 1. ill 1.0 0.8 0.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 13 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- !.!13/22/86 Qll: !llf2) !?.13/22/86 Ql3: 0!!1 QIZ./22/86 1215: 0!!1 {::1:5/22/86 1217: !!1121 Ql3/22/86 !!19: 0f2! 0:::::/22/86 11: f!l~l 03/22/86 13:00 03/22/86 15: 12H:~I 03/22/86 17:00 ;zJ:::;;/22/86 19: 0(!1 ~13/22/86 21:0121 03/22/86 23: flll!l i!13/23/86 Qll: 1210 0:3/2:~./86 ~!J3: 0Qi 0~~/23/86 !ZI5; 00 03/23/86 07: 0!21 !!13/23/86 !219: 01!1 Ql3/23/86 11: Y.lt.i'l 1!13/23/86 13: fll!2i 03./23/86 15: !!10 !213/23/86 17: 0!11 1:!1:5/23/86 19:0121 !213/23/ 86 21 : Y.IY.I Ql3/23/86 23: 1'211!1 !!13/24/86 01:00 1213/24/86 1!13: fll0 03/24/86 05:00 1!13/24/86 07: !ZII!I 03/24/86 1219: Qll21 !!13/24/86 11: !!hZI Y-13/24/86 13: i2lf21 1213/24/86 15:121121 1!1:3/24/86 17: 0J!l Ql3/24/86 19: !!11!1 1:~1:5/24/86 21.: Ql!Zl 1!.13/24/86 23: Qil!l BYTE RAW DATA ========== 853 95 56 855 94 54 857 93 52 859 92 5Lil 861 91 5121 863 91 51 865 91 52 867 93 54 869 94 57 871 96 60 873 96 6121 875 95 58 DAILY AVERAGE VALUES 877 94 55 879 92 53 881 91 51 883 9121 5121 885 9fll 50 887 91 52 889 92 53 891 94 54 893 94 56 895 96 59 897 97 61 899 97 61.!1 DAILY AVERAGE VALUES 901 9J!13 91215 91217 909 911 913 915 917 919 921 97 59 97 58 97 58 97 58 98 58 98 59 Hl0 61 1Ql1 63 Hl3 64 1!ll4 65 1 i2l5 65 923 Hi4 6::;:; DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 4.5 4.4 4.3 4.2 4.1 4. 1 4.1 4.3 4.4 4.6 4.6 4.5 4.3 4.4 4.2 4. 1 4.0 4.0 4.1 4.2 4.4 4.4 4.6 4.7 4.7 4.3 4.7 4.7 4.7 4.7 4.8 4.8 5. 1!1 5. 1 5.3 5.4 r:: r:: ..., . ..., 5.4 5.0 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ====== ~~. 6 l!l. 4 Ill. 2 0. Ql 0.0 l!i. 1 (21. 2 0.4 0.7 1.0 1.0 0.8 0.5 0.1 0.0 0.0 0.2 0.3 1!1. 4 0.6 121. 9 1. 1 1. 0 0.5 121. 9 0.8 0.8 0.8 121.8 0.9 1.1 1.3 1.4 1.5 1.5 1. 3 1. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page :lA 12-~12~87 DATA FILE : TREBARflll BRADLEY LAI<E HYDRO PROJECT START: 1!12/ 14/86 13: Ql(il BRADLEY RIVER -TREE BAR REACH STOP: ~~4/1218/86 15:33 CHAN 1 CHAN 2 DATE TIME BYTE RAW DATA DEG c. DEG c. ======== ===== -----========== ------------------------ !Zl3/25/86 1!11 : !2lloi! 925 Hl3 62 c:-..,.. ...J • ._\ 1.2 1!13/25/86 1213: Qllll 927 11212 6121 5.2 1. Ill (il3/25/86 1!15: ~10 929 11'.!12 6121 5.2 1.121 !!13/25/86 fll7: @!l 931 11!12 61ZI C" ~) i.J ..... 1. 0 1?.3/25/86 e19: 1210 933 103 61 o:::-..,. ~o.J • ._\ 1.1 1!13/25/86 11: 0121 935 li!l3 62 5.3 1.2 1!13/25/86 13: Ql0 937 11213 62 5.3 1.2 03/25/86 15: Qlf2l 939 11213 6..,. ._, 5.3 1.3 $-!1:'~:/25/86 17: !ll0 941 HS3 63 5.3 1. 3 !!13/25/86 19: liS0 943 U!13 61 5.3 1.1 !213/25/86 21:00 945 Hl3 60 5.3 1. 0 03/25/86 23: 01!1 947 101 58 5. 1 (!1. 8 DAILY AVERAGE VALUES C" ..,. t..J •....... 1. 1 03/26/86 I!H : !210 949 99 56 4.9 ll!.6 03/26/86 03: 09.1 951 99 54 4.9 0.4 {213/26/86 1215: !!1es 9=-..,. ,_}._\ 10121 52 5.0 0.2 !213/26/,86 fl.l7:00 955 98 52 4.8 121. 2 1!13/26/86 !!1 9 : 121121 957 97 51 4.7 0.1 03/26/86 11! Qli.ZI 959 96 51 4.6 0.1 !!13/26/86 13: 0121 961 96 51 4.6 0.1 03/26/86 15: 0Y.1 963 97 52 4.7 S!1. 2 1[13/26/86 17!!!10 965 HJI!I 52 5. 121 ,!1. 2 IZI::~/26/86 19: 0!21 967 99 52 4.9 0.2 !Zl3/26/86 21 : !21!21 969 98 53 4.e 0.3 1213/26/86 23: fc':H!I 971 99 51 4.9 !21. 1 DAILY AVERAGE VALUES 4.8 121. 2 £1:::::;zJ ;e6 Ql1 : "!lfll 973 100 49 5.0 -~1. 1 1(.13/27 /86 lll3: Ill Ill 975 1012J 5!21 5.0 0.0 !:!13/27/86 ass: 1210 977 1!213 49 5.3 -0.1 IZI3/27 /86 ~17: !ZII!I 979 102 50 5.2 1!1. 0 !ll3/27 /86 ~':>9 : fO (IS 981 11.111 50 5.1 0.0 !ZI3/27 /86 1 1 : !!1121 983 Hl0 51!1 -. 5. !21 0.0 $213/27/86 13: @21 985 1121121 51ll 5. f2S Ql. {21 Y-13/27/86 15: f!S!ll 987 1 fll!21 5121 5.1!1 fll. !21 03/27/86 1 7 ~ {!1121 989 HH 50 5.1 0.0 1!13/27 /86 1 9: Y.H!I 991 Hl1 51!S 5.1 121. !21 "!13/27/86 21 : i!l!ll 993 1Ql1 5!-!1 5.1 121 • fZI 03/27/86 23: ~!iQi 9':Y5 Hll 50 5.1 fll. f21 DAILY AVERAGE VALUES 5. 1 -121. 0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-Ql.l DEG C TEMP/TEMP RECORDER Page 15 12-fll2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TII'1E ----------------===== Q!3/28/86 01: 0!'ll 03/28/86 1213: 1!11!1 1213/28/86 05: 1!10 l!f5/28/86 1!17: 01!1 !213/28/86 k:l9: J!l!ll 03/28/86 11: V.l0 1!13/28/86 13:00 {213/28/86 15: Qll21 f.!l3/28/86 17:00 !!13128./86 19: QIQ! 1213/28/86 21:00 1213/28/86 23: 01!1 03/29/86 01: Ui!!l rtl3/29/86 03: ~!i0 1!13/29/86 ~15: Y.lf!l 1213/29./86 07:00 03/29/86 1219: 1!10 ~!13/29/86 11:1210 03/29/86 13:!...iSI21 el3/29/86 15:1.:10 1!13/29 I 86 17: 121121 ~!13/29/86 19: 012! !!13 /29 I 86 21 : !!l!ZI Ql3/29/86 23:1210 1213/3(4/86 (.!11: 1'110 03/30/86 (!13: 01!1 03/3121/86 f!l5: 1210 ~!13/3Qi/86 !217: !2H!I !ll3 I 3!!1 I 86 !219: 00 03/31!1186 11:!!it2l Ql3/3!l.l/86 1.3:00 12i3/3QI/86 15: 0Y.i 1'113 / 3Ql/ 86 1 7: 121121 121:::;: I 3!!1 /86 19: 01!! !Zl3/3QIIB6 21: 121!.21 1!.1:::;'./ ::.~121 /86 Z:3: Y.iQI BYTE RAW DATA ==== ========== 997 11llf21 49 999 101 5!!1 101211 105 50 1003 105 50 112105 105 5121 101217 l!...iS4 50 112>09 103 50 1121 11 1 03 5e1 1013 1£13 50 112115 102 50 1017 102 50 1019 101 50 DAILY AVERAGE VALUES 112121 101 5J!I 1023 HH 50 1025 102 50 1 Y.l27 1 fll2 50 112'29 1 t..il0 50 112131 100 50 1033 100 50 1035 1 !2J121 5121 1037 1 flilll 50 11ZI39 1!210 50 1041 100 50 1Y.14 3 1l!U!i 510 DAILY AVERAGE VALUES 1045 99 50 112147 99 50 1049 99 5121 112151 99 50 1053 93 50 1l!l55 89 50 112157 88 50 112159 88 50 1061 87 5121 l~l63 87 50 1l2165 88 50 1!ll67 88 50 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 5.0 5. 1 5.5 5.5 5.5 5.4 5.3 5.3 5.3 5.2 5.2 5.1 5. 1 5.1 5.2 5.2 5. Ill 5.121 5. 121 5. Ill 5. !2S 5. ~1 5.0 5.1'c:1 5. f2l 4.9 4.9 4.9 4.9 4.3 3.9 3.8 3.8 3.7 3.7 3.8 3.8 4.2 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08186 15:33 CHAN 2 DEG C. ------------ -121. 1 121.0 !21. f2l 0.0 0.0 !£1. 0 0.0 !£1. 0 0.0 ill. 0 0.0 0.0 -0.0 0.0 0.0 0.0 0.0 Ill. 0 fll. 0 0.0 0. 121 0. 121 0. !21 0. 12> flS. 121 0. 1!1 0.0 0. 121 121.0 Ill. 121 121. 0 0.0 121. 0 0. !21 0.0 0. 121 fll. £! 0. l!l 121. 0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-J!!. 1 DEG C TEMP/TEMP RECORDER Page 16 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TII1E ======== ---------- Q131::H I 86 01 : Y.IQ! 1213 I 31 I 86 !213: !!1121 !2J3/ :'..\ 1 / 86 f!l5: f!lll! ll13/ ::,:;; 1186 ~17: 1211li 03/31/86 $219: 1!10 !!131 31 I 86 11 : l!lf!l !213131186 13:fiHo ~13131/86 15:!210 03/31/86 17:00 !213131 186 19: 0Ql 1213131/86 21:01t.l 1!13131/86 23: IZh!l ~3411!11 186 !211: ~lfll !214 / 1!11 /86 1213: 0121 04/!!11 /86 !215: &21121 04/!!11 /86 07:00 1?.14/1!11 I 86 1219 : 1210 04/kH /86 11: 0fll 1214/I!H /86 13: 1!10 Ql4/!:?11 /86 15: 00 !214/1!11/86 1 7: !ll!21 !214 I llil I 86 1 9 : Ql!ll 1!14 /1!11/86 21 : 12H!l 1<'14 /~11/86 23: 00 1!14 I IZI2/ 86 !l> 1 : rllf!l 04/02/86 1!13: 00 0411212/86 05:1210 1214/02186 1217:1!10 !214/!!12/86 1:!19: !!10 1!14/IZI2/86 11: !!1!21 1!14 I !212 I 86 13: flll!1 !!14~/!-!12/86 15: 01.!1 04n32/86 17:00 1!14/!212/86 19: !ll!!i !l.l4/iZ12/86 21.: 121~!1 !214/1!12/86 23: !21!!1 BYTE RAW DATA -------------------- 112169 88 5fi.l 1071 88 50 112173 87 $!1 Hl75 87 5121 1077 87 50 11!.179 87 50 11!181 87 50 1083 87 50 1085 87 50 1087 87 51!1 1089 87 50 1 !2i91 87 5ill DAILY AVERAGE VALUES 1!!193 87 50 1095 87 5!.!1 1097 87 50 1099 86 49 111!11 86 50 11 !l13 75 5S!1 11!!15 54 49 1107 51?1 51ll 11 1!19 5t!) 5!!1 1 111 5f21 5121 1113 50 50 1115 5!21 50 DAILY AVERAGE VALUES 1117 50 5!21 1119 50 50 1121 51ll 50 1123 50 50 1125 5121 5121 1127 50 50 1129 51 51 1131 52 51 1133 52 51 1135 52 51 1137 51 5121 1139 51 5~1 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 3.8 3.8 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.6 3.6 2.5 0.4 0.rc 0. 121 0.0 0.~ 0. 1!1 1. 8 1!1. 0 0.0 121. 121 0.0 Y.l. 0 {21 • 121 0.1 0.2 !(). 2 0.2 0.1 Ql. 1 0.1 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ====== 0. f{j 0. !!I 121. 0 0. ~~ Ill. !ell 0. f!l !21. 0 0.0 !21. 0 0.0 0.0 0.0 0.0 !21. Ql k1. 0 0.0 -0.1 0.0 0.0 -0. 1 Ill. Ill !l1. 1!1 121.0 Ql. 1!1 0.0 -1!1. !21 0. Ql 0.0 0.0 0.0 1!1. l!l 1!1. 0 121. 1 f!l. 1 0.1 0.1 Qi. IZI 0. 1!1 0. t!l ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-02~87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ... __ .,. _____ _ --------===== fil4/l!l3/86 !211; Y.H!l (!.14/~13/86 1!13: 00 !!.14d1.13/86 !:!15: 00 !!14/1!13/86 !217: Qll!l Qi4/l!J3/86 09:00 i2i4 I 1213 I 86 11 : 1~121 t.:l4/QI3/86 13:010 !Zi4/l!l3/86 15:0121 Ql4/03/86 17: €10 1!14 I 12S3/86 1 9: 0121 IZI4/~!13/86 21:00 !214 / 1!13 I 86 23: 12J0 BYTE RAW DATA ========== 11~H 51 50 1143 51 5121 1145 51 50 114 7 51 5Ql 1149 51 5~1 1151 52 51 1153 52 52 1155 53 52 1157 53 51 1159 52 51 1161 52 50 1163 52 51!1 DAILY AVERAGE VALUES 1!14 I 1214 I 86 !211 : 0!21 !214 I IZ14 I 86 03: 00 04 I 04 I 86 !215: !ZIY.I ~14/!!14/86 07: 1!10 1!14 I !ZI4 I 86 1219: V.IQI £14/1214/86 11:00 lt.14/rl14/86 13: !210 04/~14/86 15: 0!21 l!l4/QI4/86 17:00 1!14/1214/86 19: !210 1214/1!14/86 21: J!HZI 1!14/1!14/86 23:0121 Ql4/l!l5/86 01: fllf21 04/1215/86 1213: IZIQI f2i4/fl.l5/86 05:00 1!14/!!S5/86 07:00 04/1!15/86 Y.l9: 1210 1!14/ !!15/86 11 : 1!1~1 rZl4h!l5/86 13:1210 ,;:14/05/86 15:121121 04/QI5/86 17:!210 i!l4/05/86 19: 01!1 !!14/05/86 21: £1!21 i214/IZI5/86 23: rliiZI 1165 53 50 1167 87 50 1169 88 5!!1 1171 85 5121 1173 53 50 1175 51 51 1177 52 52 1179 53 52 1181 53 52 1183 52 51 1185 52 51 1187 52 51 DAILY AVERAGE 1189 52 51 1191 52 51 1193 52 51 1195 52 51 1197 52 51 1199 52 51 1201 53 51 1203 53 51 121215 52 51 121!17 52 50 120'=! 52 50 1211 52 5QI DAILY AVERAGE VALUES VALUES CHAN 1 DEG C. ====== 121. 1 Ql. 1 0.1 0.l. 121. 1 0.2 0.2 0.3 0.3 0.2 0.2 !G1. 2 0.2 0.3 3.7 3.8 3.5 0.3 0.1 0.2 0.3 0.3 0.2 1!1. ~ 0.2 1. 1 f.!l. 2 0.2 121. 2 0.2 0.2 121. 2 0.3 0.3 0.2 Ill. 2 121. 2 J!f. 2 0.2 DATA FILE : TREBAR01 START: 02/14/86 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C . ------------ 121 • l!l 0. t/1 fc!l. l!l 0. Ill Ql. 0 0.1 0.2 0.2 0.1 rZ!. 1 f2l. 0 !!1. 0 0.1 Ill. 0 121. 0 0.0 121. 121 Ill. !.!1 0.1 0.2 0.2 12~. 2 fll. 1 0.1 ~~-1 J!l. 1 Ill. 1 V.I. 1 0.1 0.1 121. 1 0.1 121. 1 0. 1 0.1 Ql. 1!1 121.0 0. Y.l 121. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 18 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME __ .. _____ _ --------===== 04/1216/86 (i.i 1: k_?Ql !214/ !216/86 1!13: llir!l 04 /06 / 86 1!~5 : ~~10 !214/!!16/86 1!17: Ql!!i 12l4/IZI6/86 09: I!H!l IZI4/I!l6/86 11: t2l!2l 04/ll16/86 13:00 12!4/1216/86 15: 13~1 f214/06/86 17:1210 1214/!216/86 19:121121 ll.14/IZI6/86 21: IZ10 ~14/!1.16/86 23: f£H!I 04/1217/86 flll: 0Ql !214/07 /86 1213:0121 04/!!17/86 1215: !211!1 ~!14/1217 /86 07: !.!1!21 04/1!17 I 86 !219: 0!!1 f2l4lr.:T7 /86 11 : 0121 04/1!17/86 13: ~1121 Ql4/~17/8tl 15:00 !214/!217 /86 17: !210 04/!217 186 19: 0!21 1!14/QI7/86 21:1!10 04/1217186 23: 00 04/1218186 1211: IZIQI 1!.14 I 1218 I 86 !213: 0!ll 0411218/86 05: 0Y.I ~14/1218186 1217: 121!21 !214/!218/86 1219: 0f.!l !~1411218/86 11: 0!!1 1~14/!218/86 13: !lh'21 BYTE RAW DATA ========== 1213 52 5~:1 1215 52 50 1217 52 5f21 1219 52 50 1221 51 50 1223 51 50 1225 52 50 1227 51 50 1229 51 51'21 1231 51 5121 1233 51 5!(j 1235 51 50 DAILY AVERAGE VALUES 1237 51 51!1 1239 51 5121 1241 51 5121 1243 51 51ZI 1245 51!1 50 1247 51 50 1249 51 50 1251 50 50 1253 51!1 50 1255 5!21 5121 1257 51 50 1259 5121 5121 DAILY AVERAGE VALUES 1261 50 50 1263 50 50 1265 5121 50 1267 50 50 1269 59.1 50 1271 5~1 50 1273 50 5QI DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 0.2 121. 2 fZI. 2 1!1. 2 0.1 0. 1 0.2 0.1 0.1 0. 1 0.1 121. 1 0.1 0.1 0.1 121. 1 0.1 {.!1 • 121 0.1 121. 1 0.0 {21. f2l 0Q0 0.t 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0. Y.l 0.0 0. 121 DATA FILE : TREBAR01 START: 02114186 13:00 STOP: 04/08/86 15:33 CHAN 2 DEG C. ====== 121 • 121 0. Ql Ill. 121 0. 121 0. 121 0.0 121.121 0. Y.l 0.0 0.0 0.0 0. Y.l 0.0 0.121 Ql. Y.l 0. Ill 0.0 0.121 0.0 0. Ill 0.0 !ZI. 121 Ill. 121 0.0 0.0 0.0 0.0 0. Ill 0.0 U1. 0 il. 121 0.0 0. Ill 0. 121 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-li.l2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH BEGIN OBS :CHECKING FOR ADDITIONAL INFORMATION END OBS :SAME AS BEGINNING DATE TIME -------------------------- !!14/1!18/86 16: 1-!10 Ql4/i!l8/86 18: IZS!il 1!14/08/86 20:00 1!14/1!)8/86 22:V.II!l 194/1!19 /86 01!1: 0121 1!14 I 1Zl9/86 Jll2: i!l0 !ZI4/!Zl9 I 86 Q)4: !!liZ! Y.l-'U 1!19 I 86 1!16: 01!1 1214/!!19 I 86 08: !Zil!! 1!14/09186 HI: ~11i.l !!14/1!)9/86 12:00 1214/ 1!19/86 14: !!1121 1214/9.19/86 16: 0!21 !214 I Ql9 I 86 18: 1211!1 Ql4./1!19/86 2f?l: 0121 1!14 I 09 I 86 22: 121!!1 i!14/1121 I 86 01!1: 1!10 Ql4/l!Zi 186 1!12: Iii!.!! 04/1 i.?l/86 04: 00 1!14/ 1!21/86 1!16: Ql0 li.l4/ lk!l/86 08: I21Ql IZ14/ H!l/86 10: .121!!1 04/ 1!21/86 12: fll~l 1214/ !Ql/86 14:1210 !2141 Hl/86 16:00 l!i4/1QI/86 18:0121 1!14 I H!l/86 20: !210 1214/ 11!1/86 22: 1211!1 Ql4/1 1 I 86 1!11!1: 0fZI !!14/11186 !l12:1!1!21 1!14 I 11 186 Q14: Y.l!!i !~14/11/86 1!16: 1!1!21 !214/11/86 QI8:!!H21 04/11./86 10:!!10 IZI41 11/86 12: f.(IQI 1!.14111/86 14:1!10 1?.14 I 11 I 86 16: 0121 04/11/86 18: 0~:S !214111/86 21!l:I!IQI 1214/11/86 22: IIIQI BYTE RAW DATA ========== 1 51Zl 5t!l 3 50 49 5 5f2l 512! 7 50 50 DAILY AVERAGE VALUES 9 50 50 11 51Zl 50 13 50 50 15 5Y.! 50 17 50 50 19 50 5121 21 50 50 23 50 50 25 50 5fll 27 50 5fl! 29 50 50 31 50 50 DAILY AVERAGE VALUES 33 50 50 35 50 50 37 51Zl 50 39 50 5121 41 5121 5121 43 51 51 45 51 51 47 52 52 49 52 52 51 52 52 53 51 51 55 51 51 DAILY AVERAGE VALUES 57 51 51 59 51 51 61 52 51 63 52 51 65 52 51 67 53 52 69 53 52 71 53 53 73 53 53 75 53 52 77 54 52 79 53 51 DAILY AVERAGE VALUES CHAN 1 DEG C. -·----------- 1!1 • 121 !21. 0 0.0 0. Ill 0.121 Ql. 0 0.0 0. 1!1 0 .ill Ql • 121 0.0 0. 121 0.0 0.0 121. 0 @.0 121. 0 0. IZI 0.0 0.0 0.0 0. ttl Ill. 0 ttl. 1 0.1 0.2 0.2 0.2 0.1 0. 1 0.1 !!I. 1 0.1 0.2 0.2 Y.!. 2 Ill. 3 0.3 0.3 0.3 0.4 DATA FILE : TREBAR02 START: 04108/86 16:00 STOP: 06/18186 12:06 CHAN 2 DEG C. ====== 121 • 121 -121. 1 121.0 0.0 -121. 0 fll. Ql 0. !21 121. 0 121. Ill 0.0 0.0 0. 121 0. Ill 0.0 121.0 0.0 121. IZI V.I. 121 0. t!l 1!1. 0 0.0 0. 1!1 121 • Ill 0. 1 0.1 0.2 0.2 0.2 0. 1 121. 1 0.1 1!1. 1 1!1. 1 121. 1 0.1 121. 1 121. 2 0.2 Ill. 3 0.3 0.2 0.2 0.1 0 ..., ..... ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 04/12/86 Y.l!ZI: Ql(i} t!l4/ 12/86 1212: !Zil!l 1!14 I 12 I 86 1214 : !Zl,~l !2141 12/86 1216: Y.I!ZI Jil4 I 12/86 !.!18 : 121!21 ~14/12/86 10:1ill21 Ql4/ 12196 12:00 04/12196 14:1'!10 !!14112/96 16:00 1!14/ 12186 18: 0!21 IZI4/12186 21!1: 00 t!i4 I 12/86 22: !210 04113186 J2j0: 1210 Ql4/13/86 02:00 ~54 I 13/86 04: 121121 1Zl4/131 86 f216: !{J0 1214 I 13 I 86 1219: i!lt2! 04113/86 10:00 {214113186 12:0~1 04/13186 14:00 1214113186 16: 1211!1 !.2141 13/96 18: 121!21 04/13186 20: 1211!1 !iJ4 I 1 3 I 96 22: 1211!! ll14 I 14/86 ll10: !210 1214/14/86 1!12: 0!21 Ql4114/86 04:00 {214/14186 1216:00 !214 I 1 4 I 86 1218: 121!.!1 ~141 14186 l!II: l!Hil 1214/14186 12: !!11!1 i!l4114/86 14:121!21 1!141 14/86 16: 12HZ! 9.14114186 18: (!IQI £!4 I 14/86 2121: 00 1.!141 14186 22: 1!1121 BYTE RAW DATA ==== ========== 81 53 51 83 54 52 85 53 52 87 54 52 89 54 53 91 54 54 93 56 55 95 56 55 97 57 55 99 57 55 11211 58 55 103 59 55 DAILY AVERAGE VALUES 1QJ5 59 55 107 59 55 109 59 55 111 60 55 113 60 55 115 61 56 117 62 56 119 62 57 121 63 58 123 64 58 125 64 58 127 65 59 DAILY AVERAGE VALUES 129 66 59 131 66 59 133 66 58 135 66 58 137 66 58 139 66 59 141 67 60 143 67 60 145 68 61 147 69 62 149 69 63 151 71!1 62 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 0.4 0.3 0.4 0.4 0.4 0.6 1.!1. 6 0.7 0.7 0.8 0.9 0.5 £!1. 9 0.9 0.9 1 •. JZI 1. 121 1.1 1.2 1.2 1. 3 1.4 1.4 1.5 1.2 1.6 1.6 1.6 1.6 1.6 1.6 1.7 1. 7 1.8 1.9 1.9 1.7 DATA FILE : TREBAR02 START: 04/08186 16:00 STOP: 06/18186 12:06 CHAN 2 DEG C. ====== 0.1 121. 2 0.2 0.2 0.3 !21. 4 0.5 0.5 ~1. 5 0.5 0.5 0.5 0.4 0.5 Ill. 5 0.5 Ill. 5 0.5 rll. 6 121. 6 ~~. 7 0.8 0.8 1.!1. 8 0.9 0.6 0.9 Ill. 9 Ill. 8 0.8 0.8 0.9 1.0 1 • 121 1.1 1.2 1" 3 1.2 1.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE --------·-------- TIME ===== fil4/15/86 IZ10:f!0 !!.14/ 15/86 02: !lll!l 1214/ 15/86 1214: Qlfll !!14/ 15/86 12i6: !!liZ! 1214/15/86 !ll8:t!i0 04 I 1 5 I 86 10 : fZII!I !214/ 15/86 12:00 !214/ 15/86 14: 12h21 !214/ 15/86 16: 1!10 ~!14/15/86 18:01ZI 1.!14/ 15/86 2!21: 00 !214/ 15/86 22:0121 04/16/86 00:1!1l!S 1214/16/86 02:00 i214/ 16/86 1214: @!li 1214/ 16/86 fll6: ~<::11!1 04/16/86 {218: 00 1214/16/86 10: LiS0 1!14/16/86 12:00 04/16/86 14:00 V.14/ 16/86 16: 01Zi 1214/16/86 18:00 1214/16/86 2,!1: 0121 1214/16/86 22:0121 lll4/17/86 f/)1!1:00 1214 I 1 7 l 86 fll2: !lle!i 1214/17/86 !214:00 Ql4 I 1 7 I 86 Q!6: 1211!1 !214/ 17/86 08: Lilfll 1214 / 1 7 / 86 1121: !!I ill Ql4/17/86 12: 0!21 1!14 I 1 7 /86 1 4: !210 1!14/17/86 16:121121 !l14/17/86 18:!!1(.11 !!lit/ 17/86 2i?.l: 00 ~~14/17/86 22:1211!1 BYTE RAW DATA ========== 153 69 61 155 69 59 157 68 58 159 68 58 161 68 58 163 67 58 165 68 58 167 68 59 169 69 6121 171 7!ll 61 173 71 63 175 91 64 DAILY AVERAGE VALUES 177 111 63 179 111 62 181 110 61 183 109 6121 185 108 60 187 108 61 189 108 63 191 109 65 193 109 67 195 110 69 197 112 71 199 112 70 DAILY AVERAGE VALUES 201 111 67 21213 110 63 21Z15 109 61 207 1k18 59 21219 107 59 211 107 61 213 107 63 215 108 64 217 1!219 67 219 109 68 221 110 69 223 111 69 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 1.9 1.9 1.8 1.8 1.8 1.7 1.8 1.8 1. 9 2.0 2.1 4.1 2.1 6.1 6.1 6. 121 5.9 5.8 5.8 5.8 5.9 5.9 6. Ill 6.2 6.2 6.0 6 .. 1 6. 121 5.9 5.8 5.7 5.7 5.7 5.8 5.9 5.9 6 .Ill 6.1 5.9 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 1.1 0.9 0.8 0.8 ~~-8 121. 8 0.8 Ill. 9 1. 0 1.1 1. 3 1.4 1.J!I 1.3 1.2 1. 1 1. 121 1.0 1.1 1. 3 1.5 1.7 1.9 2.1 2. Ql 1.4 1.7 1. 3 1. 1 0.9 Ill. 9 1. 1 1.3 1.4 1.7 1.8 1. 9 1.9 1.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- Y.14/18/86 ll.ll.9: l210 !!i41 18/86 Q12: ~1!21 t-!14 I 18/86 1214: tn0 Y-141 18/86 !216: 0!21 ~~14/18/ 86 {(.18: ~h!$ i2i4/181 86 1121: i!ll!! 1214/18186 12: 0!!1 04/18186 14: IZi~l 1.!14/ 18/86 16: 1!1121 !214/18/86 18: 1'21!21 04/ 18186 2£1: QI0 !214/18/86 22:121121 i214 I 1 9 I 86 f210: QIQI 1214/1 9 I 86 02: i!S!21 1214/1 9 I 86 !li4: 0fll 04119/86 1!16: 0fll 1214119/86 1218:121~1 !214 I 1 9 I 86 1 0 : 0121 1214 I 1 9 /86 12: 01ZI 1!141 19/86 14:00 12141 19186 16: l!ll21 1214 I 1 9 I 86 18: 0121 !214 / 19/86 20: {.{10 1!14/19186 22:0121 {214/2121/86 121!21: !llf!l 1214/20/86 1212: 0!21 04/2121 I 86 1214: 1210 Y.14121!1186 !216: Y.!0 ~14/20/86 !liB: 00 1!1412i!i/86 112!: 0121 QI4/212J/86 12:00 1!14 I 2t!l /86 14 : !!11!1 1214/2!..'1 / 86 16: 1210 Ql4 I 2121 I 86 18: 1!112! l2i4 / 2!21/ 86 21!1: 1211!1 QI4/2Y.I/86 22: !21!!1 BYTE RAW DATA --------------------225 110 66 227 lfll8 62 229 106 60 231 105 58 233 11214 58 235 104 59 237 104 59 239 1 IZI!ZI 62 241 1QI2 64 243 1Y.I8 65 245 109 66 247 Hi9 64 DAILY AVERAGE VALUES 249 HIS 62 251 11217 59 253 11216 56 255 105 55 257 104 55 259 11215 56 261 1!215 57 263 106 6!2l 265 l!ZI8 63 267 11218 64 269 109 64 271 Hl7 61 DAILY AVERAGE VALUES 273 105 58 275 103 55 277 102 53 279 10!21 52 281 99 52 283 11!10 54 285 101 56 287 102 60 289 1QI4 63 291 105 63 293 1Qf5 63 295 104 6121 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 6.0 5.8 5.6 5.5 5.4 5.4 5.4 5.!21 5.2 5.8 5.9 5.9 5.6 5.8 5.7 5.6 5.5 5.4 5.5 5.5 5.6 5.8 5.8 5.9 5.7 5.6 5.5 5.3 5.2 5.1ll 4.9 5.0 5.1 5.2 5.4 5.5 5.5 5.4 5.3 DATA FILE ; TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 1. 6 1.2 1. Q! ~l. 8 0.8 0.9 !21. 9 1.2 1.4 1.5 1.6 1.4 1.2 1.2 1!1. 9 fll. 6 0.5 121. 5 0.6 0.7 1. 0 1. 3 1. 4 1.4 1.1 IZS. 9 0.8 IZI. 5 0.3 0.2 0.2 0.4 0.6 1.0 1. 3 1.3 1.3 1.0 121. 7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page f:i 12-~!2~87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ----------------===== ~!14 /21 /86 !c'!l12i: fillll i?l4/21 I 86 rii2: £!!fll !!14/21/86 !.114: 00 1!14/21/86 1!16: !lll21 iZ14/2 1/86 Jll8: l!ll!S ~14/21/86 10: 1!1~1 04/21/86 12:00 !!14/21/86 14: fZI0 !ll4/21.186 16:1210 1214/21/86 18: 121!21 1:~14./21 /86 2121: Y.l0 i..if4/2 1 / 86 22: 121121 1214/22 I 86 00: llU21 1214 I 22 I 86 !Zl2 : 121121 04/22/86 04: fll0 04/22/86 !216: 00 f214/22/86 1218: IlliZI !214/22/86 HI: 1210 !!14/22/86 12: 1!10 !214/22/86 14: lllfll !ZI4/22/86 16: Qlf21 !2l4/22/86 18:00 !!14/22/86 20: !.!1121 lt.l4/22/86 22:0121 ~!14/23/86 0!!1: 0S!I 04/23/86 02: @!I 1!14/23/86 04:00 1!14/23/86 }!16: 00 1214/23/86 ~18: flll,!l i!l4/23/86 10: 01!i !214/23/86 12: 0Y.S ill4/23/86 14:1219.1 1214./23/86 16: !210 1214/23/86 18: Q'll!l 5214/23/ B6 2u1: l21lZi 1214 I 2 3 / 86 22 : l!l!Zl BYTE RAW DATA ========== 297 104 58 299 lfll3 57 3fZI1 103 56 3,!13 103 56 305 11!14 56 307 11ll4 56 31219 105 57 311 106 58 313 108 59 31 5 1 fll8 6!2l 317 1!219 60 319 108 59 DAILY AVERAGE 321 325 327 329 108 57 1!217 55 104 53 102 52 HS1 52 331 1!213 53 333 112 56 335 117 58 337 120 60 339 120 60 341 119 59 343 118 58 DAILY AVERAGE 345 116 56 347 116 53 349 120 51 351 121 50 353 120 50 355 122 53 357 123 54 359 125 57 361 123 62 363 123 66 365 124 68 367 128 66 VALUES VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 5.4 5.3 &::' ..,.. '-1 • .._, 5.3 5.4 5.4 5 .. 5 5.6 5.8 5.8 5.9 5.8 5.5 5.8 5.7 5.4 5.2 5.1 5 .. 3 6.2 6.7 7. 121 7.0 6.9 6.8 6.1 6.6 6.6 7. !2! 7. 1 7. ~~ 7.2 7.3 7.5 7.3 7.3 7.4 7.8 7.2 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 12.1. 8 12!. 7 Ql. 6 0.6 ~~. 6 0.6 0.7 0.8 ~.9 1.0 1.0 ~1. 9 0.8 0.7 0.5 0.3 0.2 0.2 0.3 0.6 0 .. 8 1.0 1. ~~ l!l. 9 Ql. 8 lll. 6 121. 6 0.3 @.3 Ill. 4 121. 7 1.2 1.6 1.8 1.6 0.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TI1'1E ======== ===== !214/24/86 (!lfZJ: 00 fZI4/24/86 1!12: !!IQI i!14/24/86 ll14: fll0 ~-~14/24/86 1!16: (!1121 ~14/24/86 ~18: 01!1 1!14/24/86 lfll: 0iil 1214/24/86 12:1210 1!14/24/86 14:00 1214/24/86 16:0121 1214/24/86 18: 0QI !!14/24/86 2!21: 00 V.14/24/86 22: 0Y.I ~:14/25/86 00:1210 1214/25/86 1212:00 1!14/25/86 17.14: 01.!1 1!14/25/86 1!16: !210 Y-i4/25/86 1218: 0Y.I 04/25/86 10:0121 m4/25/86 12: 0iil. J.:l4/25/86 14:00 1214/25/86 16: 01!1 !!14/25/86 18:00 !214/25/86 20:0121 f!l4/25 /86 22: l.!lfll !214/26/86 0121: 00 €14/26/86 ~12: 121121 12~4/26/86 04: f2Jf21 04/26/86 1216:121121 !214/26/86 fll8: 1210 !214/26/86 10! 121121 12~4/26 /86 12: f21!21 !214/26 I 86 14: C!lf21 !!14/26/86 16:0121 04/26/86 18:121121 t,i./4/26/86 2Ql: ~21121 Y-14/26/86 22: (!1{21 BYTE RAW DATA ==== -------------------- 369 129 62 371 128 59 373 129 57 375 129 55 377 128 56 379 127 58 381 126 60 383 128 64 385 131 69 387 133 71 389 129 71 391 124 67 DAILY AVERAGE VALUES 393 120 62 395 126 58 397 129 57 399 128 56 401 127 57 4f213 126 58 405 125 61 407 125 65 4i!19 124 69 411 121 70 413 125 68 415 129 64 DAILY AVERAGE VALUES 417 419 421 423 425 427 429 431 433 435 127 60 122 57 122 54 122 53 122 54 122 57 123 59 126 62 127 65 129 66 437 126 65 439 123 64 DAlLY AVERAGE VALUES CHAN 1 DEG C. ====== 7.9 7.8 7.9 7.9 7.8 7.7 7.6 7.8 8.1 8.3 7.9 7.4 7.8 7.0 7.6 7.9 7.8 7.7 7.6 7.5 7.5 7.4 7.1 7.~ 7.9 7.5 7.7 7.2 7.2 7.2 7.2 7.2 7.3 7.6 7.7 7.9 7.6 7.4 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 1.2 1!1. 9 121. 7 ~~-5 121. 6 Ill. 8 1. 0 1.4 1.9 2.1 2.1 1.7 1.2 1.2 121.8 0.7 l11. 6 121. 7 121. 8 1.1 1.5 1.9 2.0 1.8 1.4 1. 2 1. 0 121.7 "'· 4 0.3 0.4 0.9 1.2 1.5 1.6 1.5 1.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-!212~-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ----------·---------------- 1!14/27 /86 !!!!!~: 01!1 1!14/27 /86 02: m121 !214/27/86 1{14: fll!!l 1!14/27 I 86 !216: l!iY.I Ql4/27 /86 Y.l8: !2HZ! 1!14/27 /86 10: l2Hl.l ~14/27 /86 12: !21121 1!14 /27/86 14: @21 !ZI4/27 /86 16: !210 !!14/27 /86 18: !21!21 !!i4/27 /86 2~!1: 12H~ ~?14 /2 7 I 86 22: IZI!Zl 1214/28/86 (!10: 00 !214/28/86 !212: f2)121 s,:l4/28/86 f214:0!ZI 1214/28/86 1216:00 1214/28/86 1218:00 !214 / 2 8 I 86 HI: 1210 fll4/28/86 12:!21121 fll4/28/86 14: lc.'?fll !214/28/86 16: 1!1~1 !21 ... 1 /28 I 86 18: Ill Ill 1!14/28/86 2!!1: 1!1121 1!14/28/86 22: IZH!J !214 /29/86 !21!21: !21!21 12!4/29/86 V.12: S!IQI 04/29/86 1214: 0121 1!14/29 /86 !.~16: 00 1!~4/29/86 08:00 !?.14/29/86 1121: 121!21 i!14/29/86 12: 12H~I \2J4 /29 /86 14: 121121 Y-14 / 2 9 / 86 1 6: IZI!ll f!i4/29/86 18: tM'I 1!14/29/86 2!ZI:iMI !214/29/86 22: Qli!l BYTE RA~IJ DATA -·------------------- 441 121.~1 61 443 116 58 445 .121 56 447 121 55 449 122 55 451 120 58 453 12Y.I 62 455 122 69 457 124 77 459 123 8121 461 126 77 463 131 71 DAILY AVERAGE VALUES 465 129 65 467 127 61 469 125 58 471 124 56 473 124 56 475 124 60 477 126 65 479 127 73 481 128 78 483 128 75 485 131!1 69 487 129 63 DAILY AVERAGE VALUES 489 127 6~!1 491 125 58 493 125 57 495 124 56 497 124 57 499 125 62 501 129 69 51!13 134 78 51215 137 81 5!!17 136 7=j 5i219 1 :::::2 69 511 129 63 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7. '? 6.6 7.1 7. 1 7.2 7. {!! 7.0 7.2 7.4 7.3 7.6 8. l. 7.2 7.9 7.7 7.5 7.4 7.4 7.4 7.6 7.7 7.8 7.8 8. !21 7.9 7.7 7.7 7.5 7.5 7.4 7.4 7.5 7.9 8.4 8.7 8.6 8.2 7.9 7.9 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. -----------·- 1.1 0.8 0.6 !21. 5 0.5 0.8 1.2 1.9 2.7 3.0 2.7 2.1 1. 5 1.5 1.1 Ql. 8 ~~-6 0.6 1. 0 1.5 2.3 2.8 2.5 1.9 1. 3 1.5 1. fl1 0.8 ~.7 V.I. 6 0.7 1.2 1. 9 2.8 3. 1 2.5 1.9 1. 3 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME --------... ------------------ Qiit / 3~!1/ 86 1211.:1: 11.1!!1 \214 I 3121/86 11.12: 1211!1 l!l4/3l!J/86 J.~l4! IlliZI ~34 I :;.\Ql / 86 1216: ~il?i !214 /3121 I 86 1.!'18: !c~lfZJ 1214/3121/86 10: 0J!i 1214/30/86 12:0£1 04/3~.!1/86 14:0121 1214/31!1 I 86 16: 1210 1214/311.1/86 18: !21121 1214/3121/86 2!21: !ZIQI 04/31!1/86 22: 01ti Qi5/ !!11/86 0121: ~<se1 ~!15/01 186 02: !Zilli 1215 I l!!l I 86 1214: IZI!ll 1!15 I Ill 1 I 86 Ql6! 1210 fZI5/1211/86 a>8: 121"' !215/ 'HI 86 1121: !l10 12151 Y.i 1/86 12: !ZI!ll 12151!!11 186 14: f!l0 i2151rcH 186 16: 1!11!1 ~!15IY.HI86 18:!21121 1!15 I ~!11 I 86 2!Zi: !2S~l ~!15/1211/86 22:V.I!I.i Y.i51QI2/86 ~~11!1: 00 05/1212/86 !ZI2: QHll !v5/!212186 IZ14: fll£1 ~~15 I 1!12 I 86 1:':16: Qll21 el5/1212/86 1!18: 1!t~!l 1!15 / !!!2 /86 1 1!1: !211.!1 Q'i5/ll12/86 12: 1210 Y.l5 I 1!12 I 86 14: l!i!ZI 1215102/86 16: i?.ltl !ZI5/ii.12/86 18:~MI !£15/!212186 2121: 0!!1 ~15 h:.'l2 I 86 22 : f!lill BYTE RAW DATA -------------------- 513 126 61 515 517 519 521 =•23 525 527 529 531 125 59 124 58 123 57 124 59 126 65 130 73 135 81 136 82 134 77 533 131 72 535 128 68 DAILY AVERAGE VALUES 537 126 67 539 126 66 541 125 65 543 125 65 545 125 65 547 127 68 ·549 128 72 551 13~1 75 553 132 77 555 133 76 557 127 7t!l 559 123 64 DAILY AVERAGE VALUES 561 12S!i 6121 563 118 59 565 116 57 567 116 57 569 118 59 571 122 66 573 126 73 575 131 79 577 132 79 579 125 74 581 121 69 583 119 66 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.6 7.5 7.4 7.3 7.4 7.6 8.0 8.5 8.6 8.4 8.1 7.8 7.9 7.6 7.6 7.5 7.5 7.5 7.7 7.8 8.0 8.2 8.3 7.7 7.3 7.7 7.0 6.8 6.6 6.6 6.8 7.2 7.6 8. 1 8.2 7.5 7. 1 6.9 7.2 DATA FILE : TREBAR02 START: 04108186 16:00 STOP: 06118/86 12:06 CHAN 2 DEG C. ====== 1 • 1 1!1. 9 Ill. 8 !ZI. 7 !21. 9 1.5 2.3 3.1 3.2 2.7 '") .., .......... 1.8 1.8 1.7 1.6 1.5 1. 5 1.5 1.8 2.2 2.5 2.7 2.6 2. Ql 1.4 1.9 1. ill £21. 9 0.7 0.7 !21. 9 1.6 2.3 2.9 2.9 2.4 1.9 1.6 1.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-!2l2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH D~HE TIME ======== ===== (iJ51(iJ3186 Y.lill: ~i0 1!15/!213186 !!12: 12l!21 !215/1!13186 Ql4: £1!21 1!.15/1!13186 1!16: i!l{!l 12151!!13186 $218: QH!.l 1!1511!13186 111.1:12)£1 !!15/1!13186 12: Q}fl) 05103186 14: 1:1'1121 !215/!213/86 16:fli!ZI ~'15 / 1!1 :;,~I 86 18: !'21121 1215/03186 21!1: 1!10 ((.$5l!li3186 22: 1!1~1 1!151 1!14 I 86 12H!I: 121!21 £15/!214 /86 02: 00 i!15 I 1214/86 rl14: !21!21 !215/1214186 !216: Qlj~l 1!15 I 04 I 86 !218: 121 !ZI !2!5/04186 HI: 1210 !21511!14186 12: ,?121 121~; I !~4 I 86 1 4: 121{(.1 121511!14/86 16:12H~I ~~15104/86 18: fl10 12151!!14186. 20: f!l{!l 1?15IIZ14186 22: !211!1 0511215186 121£1:0121 £15/ ~15 I 86 !212 : 1!1121 1!15/05186 !!14: 01!1 1215 I lil5 I 86 lll6 : 121{!1 1215/ !2151 86 Ql8: 01tJ ~!15/1?.15186 11!1: l!1!21 !!15 11215 I 86 12: l!IQI !!15/1!15186 14: !211!1 $Zl51el5186 16: Y->fll t215/ !!15/86 18: Y.if21 5!15/!215/86 21ll: 121~~~ 1?.15/9.15/86 22: !!1!21 BYTE RAW DATA ========== 585 117 65 587 116 63 589 116 62 591 118 62 593 119 64 595 122 68 597 128 73 599 131 77 601 131 78 603 124 77 61215 118 74 6l!17 115 71 DAILY AVERAGE VALUES 609 112 67 611 111 66 613 11121 66 615 lfZI9 65 617 109 66 619 1QI9 66 621 111 68 623 116 71 625 120 74 627 121 75 629 116 73 631 116 69 DAILY AVERAGE VALUES 633 114 64 635 11121 60 637 106 58 639 11212 57 641 11216 58 643 118 64 645 122 76 647 130 88 649 135 91 651 131 87 653 121 76 655 114 69 DAILY AVERAGE 'VALUES CHAN 1 DEG C. ------------ 6.7 6.6 6.6 6.8 6.9 7.2 7.8 8.1 8.1 7.4 6.8 6.5 7.1 6.2 6.1 6. fll 5.9 5.9 5.9 6.1 6.6 7. 1!1 7.1 6.6 6.6 6.3 6.4 6.0 5 .. 6 5.2 5.6 6.8 7.2 8. "' 8.5 8.1 7.1 6.4 6.7 DATA FILE : TREBAR02 START: 04/08186 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 1.5 1. 3 1. 2 1.2 1. 4 1.8 2.3 2.7 2.8 '"") '7 ~· I 2.4 2.1 1.9 1.7 1. 6 1.6 1. 5 1.6 1.6 1. 8 2.1 2.4 2.5 2.3 1.9 1.9 1.4 1. 0 121. 8 (21. 7 IV. 8 1.4 2.6 3.8 4.1 .... ~ .:.., • I 2.6 1.9 2. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1Ql 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME --.. ·------· --------===== l!S5/lZl6/86 !!Ill!~ 0!21 Ill!::•/ !216 I 86 1!12: !210 1215/IZ16/86 1214:121!21 !!15/!!16/86 fil6: l!ll.i5. f£15/iZi6/86 $Z18:12H~I !!15/!!16/86 1!21:!.!1121 05/1216/86 12: ~iJS!I !ZI5 1!!16 I 8 6 1 4: 1!11!1 05/l216/86 16: 1!10 !215/1216/86 18: !!Hi! 1215/1216/86 20: s!H~i 1!15/!216/86 22: !!ll!l 1!15/!!17 /86 £11!1: 121121 i2l5/Y.i7 /86 Q12: 0!21 !215 I !217 /86 !214: !21!!1 1!15/J-21? /86 06: !210 !215/!!17/86 1218:1210 Y.l5/ !217 /86 10: !!l!il · !?.15/!!17 /86 12: fll!Zl i.!15 I Ql7 I 86 14: !21121 05/!!l7 /86 16: 1!1!!1 i!15/I!O /86 18: 1210 05/!217 /86 21ZI: 121!21 05/!!.17/86 22: 1211!1 !:!15 /1218/86 !21121: !210 !215/08/86 !212: Ql!ll 05/1218/86 !214: 0Ql 05/1!18/86 1216: 121121 1215/1218/96 1219:130 1215/!!18/86 1!!1: i!10 !215/1218/86 12:00 05/1<':18/86 14:12S!ZI 1!15/1!18/86 16: ~!ll!l l215/i!l8/86 18:121121 ~::15hm/B6 2111: eses !ll5/!ii9/86 22: !!lfi.i BYTE RAW DATA --------------------657 112 66 659 111 63 661 11219 61 663 11Y.l 61 665 119 64 667 123 69 669 127 78 671 131 85 673 131 85 675 132 79 677 128 73 679 125 68 DAILY AVERAGE VALUES 681 125 64 683 123 61 685 122 60 687 121 60 689 123 62 691 125 68 693 13121 77 695 135 84 697 137 84 699 136 80 71!11 132 75 7f!13 128 7Ql DAILY A'v'ERAGE VALUES 705 127 68 7(?J7 125 66 709 124 66 711 123 66 713 124 68 715 126 72 717 128 75 719 129 77 721 129 77 723 127 74 725 125 69 727 124 66 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.2 6. 1 5.9 6. !21 6.9 7.3 7.7 8.1 8.1 8.2 7.8 7.5 7.1 7.5 7.3 7.2 7.1 7.3 7.5 8.0 8.5 9.7 8.6 8.2 7.8 7.8 7.7 7.5 7.4 7.3 7.4 7.6 7.8 7.9 7.8 7.7 7.5 7.4 7.6 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 1. 6 1. 3 1. 1 1. 1 1.4 1.9 2.8 3.5 3.5 2.9 2.3 1.8 2.1 1.4 1. 1 1.0 1. ~~ 1.2 1. 8 2.7 3.4 3.4 2. 1!1 1.8 1.6 1.6 1. 6 1.8 2.2 2.5 2.7 2.7 2.4 1.9 1.6 2.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-Ql2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH Df~TE TIME ======== ---------- !215/ !Zl9 /86 ~~Hi.!: ~:ll.il 1215/1219/86 02:~1121 Ql5/12!9 /86 1214: @21 9.15 I !!19 I 86 1216: QIQl 1215/!ZI9/86 !!18:1ZIY.l 1!15/!!19/86 11!1: V.HZI 1215/1219/86 12: !!JI.!I !!15/1219/86 14:1210 !-!15/i!l9/86 16:00 !215/1!19/86 18: V.I!ZI ~:15/!ZI9/86 2~1! ~10 !215/1!19/86 22! !ZIV.I Ql5/ll!l/86 1210: !211!1 Ql5/ 11.21/86 !Zl2: IZI!ZI !215/ 1121/86 1214: l!l!!l l1J5/li!i I 86 06 : 0QI 1215/ 1§?1/86 !258: 1210 1215/10/86 11!1: 00 1215/ 11!1/86 12:121121 1215/10/86 14: 0!21 !!15/ HI /86 16: !ZSQI ~!15 / HI /86 1 8: !Zl! .. il !!15/ l!ZI/86 2121: !liQI 05/10/86 22: 1210 1!15/ 11/86 !Zifll: 121£1 !215/1 1/86 1212 : QlQI !215/ 1l /86 !214: 00 !215/ 11/86 06: 1210 Y-15/11/86 1118:00 !ZI5 / 11/86 U!l: 121!21 !215/11/86 12:Qif21 1215/11/86 14:00 ~15/11/86 16:fi1!!l 1!15/ i 1/86 18: i!ll!i !215/11 /86 2!!1: l2l!2l l-!15 / 1 1 /86 22: 1!1121 BYTE RAW DATA ==== --------------------729 122 64 731 122 62 733 122 62 735 123 6::::. 737 125 65 739 128 69 741 130 74 743 128 76 745 129 74 747 13121 72 749 129 70 751 128 68 DAILY AVERAGE VALUES 753 128 67 755 126 66 757 125 65 759 125 65 761 125 66 763 125 67 765 128 69 767 130 69 7 69 13121 71!1 771 129 7121 773 128 68 775 126 65 DAILY AVERAGE VALUES 777 125 6121 779 124 57 781 122 55 783 124 57 785 127 61 787 129 65 789 129 7121 791 128 79 793 131 81 795 13kl 79 797 131!1 76 799 129 72 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.2 -'"") I • "- 7.2 7.3 7.5 7.8 8.0 7.8 7.9 8. Ill 7.9 7.8 7.6 7.8 7.6 7.5 7.5 7.5 7.5 7.8 8.0 8.0 7.9 7.8 7.6 7.7 7.5 7.4 7.2 7.4 7.7 7.9 7.9 7.8 8.1 8. !21 8.0 7.9 7.7 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 1.4 1. 2 1.2 1.3 1.5 1.9 2.4 2.6 2.4 .., '"") .......... 1.8 1.8 1.7 1.6 1.5 1.5 1.6 1. 7 1. 9 1.9 2. 121 2. k1 1. 8 1.5 1.7 1.0 121.7 0.5 10.7 1. 1 1.5 2.0 2.9 3. 1 2.9 2.6 2.2 1.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-121.1 DEG C TEMP/TEMP RECORDER Page 12 12-02·-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- 1?.15/ 12/a6 ~9!.!1: 00 !215/ 12/a6 !212: !li!Zl !215/12/86 Ql4:0!21 iZI5/12/86 !Zi6:fi.!IZI fll5/12/86 QI8;!21QI 05/12/86 11!1:!.!1121 1(.15/ 12/a6 12: W.1!.!1 IZI5/12/a6 14:!21121 05/ 12/a6 16: Ql0 !215/12/a6 1a:rll!21 05/ 12/a6 2!21: ~!1!!1 1?.15/ 12/a6 22: 1!10 1!15/ 13/86 1211!1: 00 ~!15/13/86 02:~1121 05/13/a6 !!14:l!I!ZI 05/13/a6 06:1ZHZI l215/13/a6 !Zla:01ZI 1!15/ 13/a6 lQI: IZHZI 1!15/13/a6 12:1211!1 1!15/13/ a6 14: !211!1 Y.15/13/a6 16: 0fll 1!15/ 13/a6 1a: 1210 !215/13/86 2QI:Ql0 !215/ 1::;/a6 22: ~Ill! 1215 I 1 4/a 6 01!1: IlliZI Ql5/14/a6 1<:12: 1!1121 1!55/14/86 04: 12!121 !215 I 14/a6 !ll6: !21!21 1215/ 14/a6 Y.la: 0121 1?.15/14/a6 1!!1: 01!1 !!15/14/86 12: (1!2) 1!15/14 /a6 1 4: QIQI 05/14/a6 16:00.1 Ql5/ 14/86 18: £1!21 !Zl5/14/a6 20:00 l!l5/14/a6 22:f!ll21 BYTE RAW DATA ========== a01 12a 68 803 127 65 805 127 63 807 127 63 809 129 65 a11 133 71 813 134 84 a15 136 93 a17 13a 96 a19 137 91 821 135 83 a23 133 75 DAILY AVERAGE VALUES 825 132 69 827 130 66 a29 129 64 a31 129 64 833 13!21 67 835 132 72 a37 131 a0 839 130 82 841 131!1 80 a43 130 77 845 130 74 a47 129 71 DAILY AVERAGE VALUES 849 12a 69 a51 128 67 a53 127 66 855 128 6a 857 130 70 859 129 75 a61 130 80 863 130 82 865 13&:!1 80 867 131!1 75 869 13121 72 871 13121 68 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 7.8 7.7 7.7 7.7 7.9 a.3 8.4 8.6 a.8 8.7 8.5 8.2 a.2 a.0 7.9 7.9 a. (!f 8o2 a.1 a.IO e.~~ a.0 8.0 7.9 a. 121 7.8 7.8 7.7 7.a a. 121 7.9 8. fll a. flf 8.0 8.0 a.0 a. 121 7.9 DATA FILE : TREBAR02 START: 04/0a/a6 16:00 STOP: 06/18/a6 12:06 CHAN 2 DEG C. ====== 1.8 1.5 1. 3 1.3 1. 5 2.1 3.4 4.3 4.6 4.1 3.3 2.5 2.6 1.9 1.6 1.4 1.4 1. 7 ..., ..., ........ 3. 121 3,2 3.0 2.7 2.4 2.1 2.2 1.9 1.7 1. 6 t.a 2.121 2.5 3. ~~ 3.2 3.0 2.5 . ., ..., ........ La ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 13 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -----------------===== V.l5/15/86 0!!l:0W 1215/15/86 ~l2:Y.I~!l Qi5/15/86 fll4: 0121 Ql5i15/86 !!16:t!I!Zl 1215/15/86 1218: QIQI 1215/15/86 U?i: !21121 1215/15/86 12: QiV.l 1!15/ 15/86 14: 1!1121 05/15/86 16:00 e-15/15/86 18: i2ll21 fll5/ 15/86 2121: ft.liZI i215/15/86 22:fiiQI 1215/ 1 6 I 8 6 §il!ZI : IZH21 1215/16/86 flS2:,!i0 05/16/86 !!14:!21121 !215/16/86 fiS6: !lllll Y-15/16/86 1218: 0(21 1215/16/86 10:1210 !215/16/86 12: lZ!!!l !1.15/ 16/86 14: 0!21 iZ15/ 16/86 16: !!i!Zl 1215/16/86 18: V.IQI i215 / 16/86 21!1: 12HZ! !Zl5/ 16/86 22: lc!-10 !Zl:':i/ 17/86 1~1!21: 00 1!15/17 /86 fll2; l!l!2i 05/17/86 !!14: 0fll 1!15 I 1 7/86 1216: !2h'Zl 05/ 1 7/86 1218: !.:1121 Ql5/1 7 I 86 HI: 1!1!21 Y.l5 / 1 7/86 12: 1210 W!:i/ 1 7/86 14: Y.HZl ~!15/17/86 16:QI!(:i 05/17/86 18:!!ii21 !!15 / 1 7/86 21?.1: I(JQI £15/17/86 22: @!I BYTE RAW DATA ========== 873 129 67 875 128 66 877 127 65 879 128 66 881 129 68 883 132 72 885 133 79 887 132 85 889 134 86 891 133 81 893 132 75 895 131 69 DAILY AVERAGE VALUES 897 131 67 899 13~) 66 901 129 64 9!ZI3 129 64 9~55 13121 66 91tl7 132 73 91219 132 80 911 13~1 83 913 131 82 915 132 80 917 132 76 919 131 72 DAILY AVERAGE VALUES 921 131 71!1 923 13!21 68 925 129 67 927 129 67 929 13121 69 931 132 75 933 133 84 935 134 91 937 137 93 939 136 88 941 135 81 943 135 75 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 7.9 7.8 7.7 7.8 7.9 8.2 8.3 8.2 8.4 8.3 8.2 8.1 8.1 8.1 8.0 7.9 7.9 8. 121 8.2 8.2 8. !ZI 8.1 8.2 8.2 8.1 8. 1 7.9 8.0 8.2 8.3 8.4 8.7 8.6 8.5 8.5 8.3 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 1.7 1.6 1.5 1.6 1.8 2.9 3.5 3.6 3. 1 2.5 1.9 1.7 1.6 1.4 1.4 1.6 2.3 3.1!1 3.0 2.6 2.2 2.3 2. !21 1.8 1.7 1.7 1. 9 2.5 3.4 4. 1 4.3 3.8 3.1 2.5 2.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DAl"A REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 14 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- !215/ 18/86 1210: 0QI \!15/18/86 1!12:1211!1 ~:!15/18/86 04:121!21 !Zi5/ 18/86 !216: !ZIY.I ~!15/18/86 1218:P.h!i 9.15/18/86 10:Qif.l ill5/ 18/86 12: 1.!10 1!15/ 18/86 14: 1210 Ql5/ 18/86 16: 1!10 Y.l:'i / 18/86 18: flit!! !215/1 8/86 21.!1: !211!1 ~115/18/86 22: 1211?.1 1215/ 1 9/86 1210: ii11!1 Ql5/ 19/86 Ql2: {!10 Y.l5/1 9 I 86 1214: 1211!1 ~15/19/86 f2l6:0f21 1!15/19/86 1218!121!21 l215/19 /86 10! 01!1 Ql5/19/86 12:11!1121 1!15/19/86 14!f~0 f1.!5/19/86 16:fll!ZI P-15/19/86 18:0121 !215/19/86 20: £'10 ~15/19/86 22!00 !215/20/86 !210: !!10 i!l5/21ll/86 i212: l!l!ll 1215/2~!1/86 1!14: 1.!10 fZI5/21!1/86 1!16: 1!1~1 !!15/21.!1/86 1218: 0QI !Z!5/21ZI/86 H!l: IZI0 .i215/2!ll/86 12: 1!1121 1!15 / 2121 I 86 14 : 1211!1 Ql5/21!1/86 16: !210 !215 I 2!21 I 86 18: 1!1!21 P-15 I 21!> I 86 2121: 1!10 1!15/2i2i/86 22: 1!11!1 BYTE 945 947 949 951 953 955 957 959 961 963 965 RAW DATA -------------------- 134 72 133 69 132 68 131 68 132 70 133 75 134 87 136 95 137 94 137 85 136 79 967 135 75 DAILY AVERAGE VALUES 969 135 71 971 133 68 973 132 65 975 131 64 977 132 66 979 134 74 981 135 88 983 136 97 985 138 97 987 138 90 989 137 81 991 136 74 DAILY AVERAGE VALUES 993 995 997 999 1 QlfZil 1QI03 1!211215 11!107 11211219 11211 1 112!13 134 69 133 66 132 64 131 65 130 68 132 76 134 87 135 93 137 94 137 87 136 79 Hl15 135 72 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 8.4 8.3 8.2 a. 1 8.2 8.3 8.4 8.6 8.7 8.7 8.6 8.5 8.4 8.5 8.3 8.2 8.1 9.2 8.4 8.5 8.6 8.8 8.8 8.? 8.6 8.5 8.4 8.3 8 • .2 8.1 8.0 8.2 8.4 8.5 8.7 8.7 8.6 8.5 8.4 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 1.9 1.8 1. 8 2. Ql 2.5 3.7 4.5 4.4 3.5 2.9 2.5 2.8 2.1 1.8 1. 5 1. 4 1. 6 .2.4 3.8 4.7 4.7 4. ~~ 3. 1 2.4 2.8 1. 9 1.6 1. 4 1.5 1.8 2.6 3.7 4.3 4.4 3.7 2.9 2.2 2.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TII"IE _ .. _,______ -·-·---------------- 1215/21/86 ~10: 1!10 S:'l5 I 21/86 1212: 121121 1215/21 I 86 12!4: 121121 1215 I 21/86 !216 : I!IY.I ~~15/21 /86 !2l8: ilJQl 1!15/21 /86 10:121121 ~15/21 /86 12:00 i!l5/21 /86 14:1210 1215/21/86 16:00 1?.15/21186 18:01!1 f215 /21/86 20: fllf21 !!15/21 /86 22: llifll 05 I 22 I 86 l!ll!l: Y.lf2! ~2!5/22/86 f2l2: 00 i~l5 I 22 I 86 1214 : 0121 !215/22/86 1216: !21~1 !215 I 22 I 86 1!18: 1211!1 it.l5122186 HI: 01!1 !215/22/86 12: QIQI k!l5/22/86 14: 0!?J 1!15122/86 16: 0lll fZI5/22/86 18: 121!21 k:l5/ 22/86 2121: 1!1!!1 t!l5/22/86 22:!lllll QJ5/23/86 00: !7.10 05/23/86 1212: !2>!21 ~Zl5/23/86 fl!4: 0121 €15/23/86 lll6: !.iliZI !?.15/23/86 1!18: r;£lf2! 1215/23/86 11!1: 1210 1215/23/86 12: !210 k:l5/23/86 14: 12HZ! 05/23/86 16:1210 {!15/23/86 18: (!@ IZ15 /23/86 2QI: QH!I €15/23/86 22: IlliZI BYTE RAW DATA ========== HH7 134 68 11!119 132 65 1Y.I21 130 64 1023 129 64 1!2125 129 66 112!27 132 75 111:129 134 88 1031 135 96 1033 138 95 1035 138 87 1037 136 78 112139 135 71 DAILY AVERAGE 1l'f41 1043 1045 1047 1049 1 S.!l51 1053 1055 112f57 1QI59 1QI61 133 67 132 67 130 67 130 67 131 69 134 77 135 88 135 95 138 94 137 87 136 79 l f2S63 135 75 VALUES DAILY AVERAGE VALUES 1!2165 134 71 1067 132 7~t1 Hl69 131 69 1071 130 69 lf2!73 131 71 1 Y.l75 134 81!1 1 ~177 136 91ll 11ll79 137 97 lt!181 140 96 11!183 138 88 1085 137 Bill 1QI87 135 74 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 8.4 8.2 8.0 7.9 7.9 8.2 8.4 8.5 8.8 8.8 8.6 8.5 8.4 8.3 8.2 8.0 8.0 8.1 8.4 8.5 8.5 8.8 8.7 8.6 8.5 8.4 8.4 8.2 8.1 8.0 8.1 8.4 8.6 8.7 9.0 8.8 8.7 8.5 8.5 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06118/86 12:06 CHAN 2 DEG C. ------------ 1.8 1.5 1. 4 1.4 1.6 2.5 3.8 4.6 4.5 3.7 2.8 2. 1 2.6 1.7 1. 7 1.7 1. 7 1. 9 2.7 3.8 4.5 4.4 3.7 2.9 2.5 2.8 2.1 2. es 1.9 1.9 2. 1 3. 1?,1 4.0 4.7 4.6 3.8 3. 121 2.4 3.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 05/24/86 1!1121: !210 !215/24/86 02: 12HZ! 05/24/86 !214: 121!?.1 !!15/24/86 !,!16: i2l0 s;:!5/24/86 !218: 00 1!15/24/86 10: {l!QI 1215/24/86 12:00 1215/24/86 14:1210 !215/24/86 16:1210 !215 /24 I 86 18: !21!!1 05/24/86 2!21: 121121 05/24/86 22: f!lfZI 12'15/25/86 121121: IZH!I 1215/25/86 02: f21QI !215/25/86 !214: fl1!tl 05/25/86 1!16: 0fZI £15/25/86 1218:121121 1215/25/86 1121:00 1!15/25/86 12:121121 05/25/86 14:121121 1"05/25/86 16:0£1 1215/25/86 18: IZS0 !!15/25/86 2l!l: 0V.f !215/25/86 22:0121 1215/26/86 fll!Zl: 1.!10 1215/26/86 1!12: f21QI 1215/26/86 IZl4: 121121 1215/26/86 IZI6: 01!1 1215/26/86 08:00 !215/26/86 lY.I: 121121 1!15/26/86 12:00 1215/26/86 14:!!1121 ,:15/26/86 16:1210 !!15/26/86 18: ~Zl!ZI 1215/26/86 2f21: lll0 05/26/86 22: !Elk:! BYTE RAW DATA ==== ========== 112189 134 69 1!!191 132 68 1093 132 67 11!195 132 68 1097 133 72 Hl99 135 81 1101 135 94 1103 136 lt£10 111215 139 99 111217 139 9fll 1 Hl9 138 81 1111 136 76 DAILY AVERAGE VALUES 1113 1115 1117 1119 1121 1123 1125 1127 1129 1131 1133 135 72 133 72 132 72 132 74 134 78 134 86 136 95 137 98 138 92 137 87 137 81 1135 136 77 DAILY AVERAGE VALUES 1137 1139 1141 1143 1145 1147 1149 135 75 133 74 133 72 133 74 133 77 134 83 135 88 1151 135 93 1153 137 93 1155 137 89 1157 137 83 1159 136 78 DAILY AVERAGE VALUES CHAN 1 DEG C. -----·------- 8.4 8.2 8.2 8.2 8.3 8.5 8.5 8.6 8.9 8.9 8.8 8.6 8.5 8.5 8.3 8.2 8.2 8.4 8.4 8.6 8.7 8.8 8.7 8.7 8.6 8.5 8.5 8.3 8.3 8.3 8.3 8.4 8.5 8.5 8.7 8.7 8.7 8.6 8.5 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 1.9 1.8 1.7 1.8 3. 1 4.4 4.9 4. ~!I 3.1 2.6 3.0 .., ..., ......... .., .., ............. .., .., ............. 2.4 2.8 3.6 4.5 4.8 4.2 3.7 2.7 2.5 2.4 2.2 2.4 2.7 3.3 3.8 4.3 4.3 3.9 3.3 2.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 17 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME BYTE RAW DATA ======== ---.. -------==== ========== Ql5/27 /86 1115/27/86 !Zl5i27 /86 Ql5/27 /86 1215/27/86 !215/27/86 05/27/86 £:15/27/86 1!15/27/86 i!i5/27 /86 !!15/27 /86 i!i5/27/86 !215/28/86 )zs::t / 2fJ / ;:3.~ ~~j:j/28t8t, i!l:=.l/ 28/86 !o!J:j/28/8o ;i);::,/ :;~:b •'86 !!I !!I : 121 Qj !21 2 : flli!l ~14: 1211!1 fil6: !!1!Zl !ZI8 : !!lt!l 11!!: 1!1121 . 12: !210 14: l!l!ll 16:0121 18:0121 2!21: 0!11 22: Q!Ql 12i~j ~ ); )· o:. .. D~f ,;i4; ikl ~!} 6 : ~i)j,!l i!.l8 ~ !Zli!l i 2: Qif2l 14: ~~~i~l 16:1~WI 18~ li.l~Ji ;~'~;:~-~ f _;: :;.· / t.~C· ~~~b; ~;:1}!: ~:~ :.··~~ J. ~:: ·:...~ / ·=~(~· .L ~~l ~ ~~~~'.1 1 161 135 74 1 163 134 73 1165 132 72 1 167 132 73 1 169 132 77 1 171 134 85 1 173 136 94 1 175 135 93 1 177 136 88 1 179 136 86 1 191 1:::.~6 83 1 193 136 8). DAlL '{ AVEF<t~GE. VALUES 1 165 1 . .,.1:::' ....;,t...,J -, , .... JC! j, J.o l lZA ."''C: I •·-' .I 1.39 13:3 '7~· 1 191 13~ ~·;-~i' 1 19.~\ 133 81 1 19~· 134 88 1 197 1..,..&:::' ._,._} 96 1 1.99 137 hbl 1 :ZI!ll 1 .,..,. ._, '! 1 V.iY.) 1.2l:!i:~:· 1412; ':;~ ::; j 2ill5 13'7 86 1 ;:::Qs·;. 1:38 _,_, •"{ CH:!I DAJ LY AvERAGE 'vALUES 1 £'i:Y-1 1 :::;6 76 121 1 1 •;•·.:::· -'...! 75 121 ~:. 1::\4 75 1215 13::::. -;:: l .... J 1:;.;:1 / 1 ..... , . .:,: .. ~:· 7d .• 'I .j • ..~: .. J, ! ::.A 2-t j., ./"..:.. ... ~ ,, J, ·-·' .:i'7 ' J.-3~ • ,( *" i ....:....t:: ••• ~l J,. !-~., '·-' ,:.~;...~:.,:', ; .. HI:;: ' ~ .. ~ 142 94 1229 141 98 1231 140 84 DAILY AVERAGE 'v'ALUES CHAN 1 DEG c. ====== 8.5 8. 4 8.2 e. 2 8.2 8. 4 8.6 8. 5 8.6 8. 6 8. 6 C.t. \:) 8. .::· ...! 8. c.:. .. ...! 8. 4 8. 3 9. 3 8. -· .:_, 8.4 8. 5 8. 7 8. 9 9. Qj 8. :1 6. a E.t. 0 8. t:· ~i. ;:, 8. 4 ·-· • ... t. ·..: \:')I' ... :• e .. ... , w .. 7 B. 9 9.2 9. 2 9. 1 9.0 8. 7 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/19/86 12:06 CHAN 2 DEG C. ------------ 2.4 2.3 2 .. 2 2.3 2.7 3.5 4.4 4. ::. ::;;. 8 ·~· .. ···-"' :::~. 1 2.8 r'} C" "-•'-' 2.5 .., -~ .._. I 3.& 4.6 5. 1 5. ~a 4. ::.: ,.,;. .. :;:_, (".\ ,...-, ............ ,;.;. . :, .' 3.9 4.9 5.3 4.4 3.8 3.4 3.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 18 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- 1215 I 3Ql /86 1!1121: 121QI l215/3!!1/86 1212: SZIQl 05/30/86 ~~14:121~1 IZ15 / 3Y.l/86 !216: 12il!l !215/312!/86 1218: i210 W.15/3f!i/86 10: Qll!i 05/30186 12: 1210 Ql5/3QI I 86 14: Y.IY.I Ill 51:3121/86 16: 0QI V.l5131Zl/86 18: l!ll!l (,!15130/86 2QI: 0Jll 05/30 I 86 22: 121!21 1!15/31/86 IlliZi: IZH!l 05/31186 12!2: 00 1215/31/86 f214:1!H!l 1215/31186 lll6:00 1215131/86 1218:00 05131/86 HI: 0J!l 05131/86 12:1!1121 1215131186 14:0121 05/31186 16:01..il ~!15/31 186 18: (!10 1215/31186 20: !!HZl ~:15/31/86 22:01!1 06/!.i.ll I 86 0!lS: 00 9.16/1211/86 1212:121~1 12161riH 186 04:1210 1216 I IZ11 I 86 1216: V.H21 1216 I 1211/86 08: !21121 1!1611!11 186 11!1: !.(IY.J 1216/!211186 12:1210 !!16 / l!f 1 /86 14 : 1!19.1 1!16/01 /86 16:00 1!16/Qil /86 18: fZIQl 06/!211186 2Ql:I!IQI i!i6 I Ql i I 86 22: !llt!l BYTE RAW DATA -------------------- 1233 138 82 1235 137 81 1237 136 80 1239 135 81 1241 135 83 1243 135 85 1245 136 88 1247 137 91 1249 ·137 90 1251 137 88 1253 138 84 1255 137 82 DAILY AVERAGE VALUES 1257 137 81 1259 136 79 1261 136 80 1263 135 79 1265 134 81 1267 135 84 1269 137 88 1271 137 90 1273 138 91 1275 139 9121 1277 138 87 1279 138 85 DAILY AVERAGE VALUES 1281 138 82 1283 137· 8121 1285 136 78 1287 136 79 1289 136 82 1291 136 86 1293 137 91 1295 138 92 1297 138 88 1299 138 87 13!211 138 84 130::::; 138 82 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 8.8 8.7 8.6 8.5 8.5 8.5 8.6 8.7 8.7 8.7 8.8 8.7 8.6 8.7 8.6 8.6 8.5 8.4 8.5 8.7 8.7 8.8 8.9 8.8 8.8 8.7 8.8 8.7 8.6 8.6 8.6 8.6 8.7 8.8 8.8 8.8 8.8 8.8 8.7 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 3.1 3. Ql 3. 1 "':"' .,. ._, . .._~ 3.5 3.8 4.1 4. {21 3.8 3.4 3.5 3.1 2.9 3.0 2.9 3.1 3.4 3.8 4.0 4.1 4.0 3.7 "':'" C' """""· ~ ..,. . s= ._,. -....1 3.2 3. e~ 2.8 2.9 3.6 4.1 4.2 3.8 ... -..:.,. • I :3.4 3.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 19 1.2-1212-87 DATA FILE : TREBARIZI2 BRADLEY LAKE HYDRO PROJECT START: 1214/08/86 16: QlQ! BRADLEY RIVER -TREE BAR REACH STOP: !216/ 18/86 12: !216 CHAN 1 CHAN '"') .... DATE TIME BYTE RAW DATA DEG c. DEG c. ---------===== -------------------------------------------------------- Qi6/1Zl2/86 121121: 1210 131215 137 8!21 8.7 3.0 i216 I C!l2 I 86 !Zl2: l.iHZI 13!!1"7 136 79 8.6 2.9 Y.I6/Ql2/86 !!14: 12HZ! 1 ::~1219 136 78 8.6 2.8 Ql6/l!l2/86 !1.16: QIY.I 1311 136 78 8.6 2.8 lb6/QS2186 !liS : 1!1121 1313 136 81 8.6 3. 1 !216/!212186 l!!l: Y.h!l 1315 136 84 8.6 3.4 Qi6h~l2186 12: 121!21 1317 137 89 8.7 3.9 1.!16/1!12186 14: 1!11!1 1319 137 89 8.7 3.9 !21611212/86 16: 121!21 1321 137 88 8.7 3.8 1216/QS2/86 18: 121121 1'"'"'" "'-'""-"-' 138 86 8.8 3.6 ~l6/QI2/86 2121: !211!1 1325 138 84 8.8 3.4 Qi61 !ZI2 I 86 22: !211!1 1327 138 83 8.8 3.3 DAILY AVERAGE VALUES 8.7 3.3 12161!!13186 0121: 121121 1329 137 82 8.7 ~ , .._ •• .4.. 1216/0::.\/86 02:£10 1331 137 81 8.7 3. 1 !216/ 1213/ 86 1!14 : l!l Ql 1333 136 81 8.6 3.1 Y.S6/1;!13186· l(j6: 1210 1335 136 82 8.6 3.2 1!1611!13/86 fll8: 121121 1337 136 83 8.6 3.3 1!161!213186 HI: 0121 1339 136 86 8.6 3.6 1216/03186 12: 0!!1 1341 137 87 8.7 3.7 Qlbll2l3186 14:00 1343 137 88 8.7 3.8 !216 / t2!3 I 86 16: 0t2i 1345 138 89 8.8 3.9 1216/1213/86 18:00 1347 138 90 8.8 4.0 ~.!)6/QI~$/86 20: Y.IQI 1349 138 88 8.8 3.8 !216/~:!13186 22:0121 1351 139 86 8.9 3.6 DAILY AVERAGE VALUES 8.7 3.5 Ql6h!l4/86 !!lf!l : !21 Ql 1353 138 84 8.8 3.4 !216 / 1!14-I 86 02: ~1£1 1355 138 84 8.8 3.4 1216/ !214 I 86 m4: QIY.I 1357 137 83 8.7 3.3 Ql6/1!14186 1!16: !21121 1359 137 8'7 ._, 8.7 3.3 !ZI6/QI4/86 08: Ql0 1361 137 84 8.7 3.4 1!16/!214/86 HI: 0121 1363 137 87 8.7 3.7 06/~~14/86 12: 0i!l 1365 137 89 8.7 3.9 1!16 I 1~14 I 86 14: l!llll 1367 138 89 8.8 3.9 !2i6/QI4/86 16: Qli!l 1369 138 88 8.8 3.8 Ql61l!l4186 18: !!11!1 1371 139 88 8.9 3.8 !!161!214/86 20: IlliZI 1373 138 86 8.8 3.6 1!16/!214/86 22: Ql!ZI 1375 138 84 8.8 3.4 DAILY AVERAGE VALUES 8.8 3.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2121 12-!212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME BYTE RAW DATA ======== ===== ========== Qi61"!l5/86 !!Ill!: QIY.l !216 I !215 /86 1212 : IZHll ~16/ J!l5 I 86 1214 : 0121 !!16 I !!15/86 ~16: Y.ll!l 1216/1215/86 1218: !21121 !216 I !!15 I 86 1121: 1211!1 06/!...il5186 12:121121 !Zl6 I {215 I 86 1 4 : fZH!I Y.l61!ZI5/86 16! IZI~ZI f216/QI5/86 18: IlliZI 06/05/86 20: 0!21 1216/05/86 22: 1!1£1 1216 / 1!16/86 IZI0: QIQI !!16/1216/86 02:1210 !216 I 06 I 86 IZ14 : i!IQI 1216106186 1!16: !!10 !!16 I 1!16 I 86 £18: 0121 06./1216/86 10: 1!1121 Y.l6 I !!16 /86 12: IZH!I 06/06186 14:0£1 1!16 I 06 I 86 16: 121121 1216/!!16/86 18:0111 1!16/1216186 2!!1: !!1121 f216 I t.!l6 / 86 22 : IZHo 06 I 07/86 0!ZI: !110 121611217/86 ·1!12: fll0 1216/07/86 04:00 06 I 1!17 I 86 06: 1210 IZ16/IZ17 186 1218:00 Y.l6 I Ql7 I 86 10: 0121 !216/ w.l7 l 86 12: IZHil 1!16/!217 /86 14: !lll!l 061W.l7 186 16: 0!21 !216 I !ll7 I 86 18 : @21 !2161 1?.17 I 86 2!21: 0!ZI Y.I611Zl7 /86 22: !~H!I 13?7 138 84 1379 137 83 1381 137 83 1383 136 83 1385 137 86 1387 138 89 1389 139 92 1391 139 95 1393 140 97 1395 141 94 1397 14121 88 1399 14121 84 DAILY AVERAGE 141211 139 82 141213 138 81 1405 138 81 14s.!l7 137 81 1409 137 83 1411 138 86 1413 139 88 1 415 14~1 9Ql 1417 14es 90 1419 138 89 1421 139 88 1423 139 87 DAILY AVERAGE 1425 139 87 1427 139 87 1429 139 86 1431 139 87 1433 141 9121 1435 142 97 1437 143 106 1439 143 l!Zl8 1441 144 U212 1443 144 97 1445 144 92 1447 143 89 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== 8.8 8.7 8.7 8.6 8.7 8.8 9.9 8.9 9.0 9. 1 9.0 9. t!l 9.9 8.9 9.8 8.8 8.7 8.7 8.8 8.9 9.0 9. 121 8.8 8.9 8.9 8.9 8.9 8.9 8.9 8.9 9.1 9.2 9.3 9.3 9.4 9.4 9.4 9.3 9.2 DATA FILE : TREBAR02 START: 04108186 16:00 STOP: 06118186 12:06 CHAN 2 DEG C. ------------ 3.4 3.3 3.6 3.9 4.2 4.5 4.7 4.4 3.8 3.4 3.8 3.2 3 .. 1 3.1 3.1 3.3 3.6 3.8 4.0 4. 1!1 3.9 3.8 3.7 3.6 3.7 3.7 3.6 3.7 4. 121 4.7 5.6 5.8 5.2 4.7 4.2 3.9 4.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 21 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ---------_ .. ___ _ ------------- Ql6 I 08/86 121121: Ql!ij 1216/1218/86 1212:121121 i!l6/1218/86 04: 0!21 i!16 I 1!18 i 86 1!16: '-!H!i 1-216/!218/86 (118: 0121 1216/1218/86 10: 1.!1121 06/1!18/86 12: J!I(!J 1216 I 1!18/ 86 14: 1210 1216/~~18./86 16: 1!1121 1216/!ZIS/86 18: 1!10 1!16/1218/86 2'.'>: 012i i!16 / 08 I 86 22: I!IIZI 1216/1219/86 01ZI: l!i~l lll6/1219 /86 1212:0121 I216/QI9/86 !214: 1!1121 '1216 / 1!19 I 86 JiJ6: Y.l0 1216 I 1!19 /86 1!18: 1210 1216 I 1:!19 I 86 10: 121121 1216/1!19/86 l.2: 121121 Y.I6/IZI9/86 14:00 i216/!ZI9/86 16:121121 Y.i6/k",9/86 18: 1.!10 i!\6 / !219 /86 20: 121!21 1!16/sZl9/86 22: J!l!21 1216 I 1121/86 i!IY.I: lll!21 es6/l!ll/86 02:121121 f!J6/ll2l/ 86 1214: 00 !216/ l!ZI/86 1!16: 121121 1216/ Hi/86 1218: 1!1121 1216 I 1 !Zi I 86 11!1: 1!1121 l.!i6 / 1121/86 12: !21Y.I i216/ 1121/86 14: 0121 1216/10/86 16: 0!21 !216 / l!!i /86 18: i!ll!l 1216/ Hl/86 2121:11.1121 !216 I 11!1 /86 22: 121121 BYTE 1449 1451 1453 1455 1457 1459 1461 1463 RAW DATA -------------------- 142 87 142 86 142 86 142 86 141 87 141 89 142 92 142 94 1465 142 95 1467 142 92 1469 142 89 1471 142 87 DAILY AVERAGE VALUES 1473 141 86 1475 141 84 1477 139 84 1479 139 85 1481 140 88 1483 141 94 1485 141 99 1487 143 11211 1489 143 11!11 1491 144 99 1493 144 95 1495 144 92 DAILY AVERAGE VALUES l.497 1499 151211 151!13 151215 151!17 151219 1511 1513 1515 l.517 143 89 143 88 142 87 142 87 142 89 143 97 145 1Ql6 146 11219 147 109 147 11215 147 99 1519 146 95 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 9.2 9 ,., •"'- 9 . .2 9.2 9.1 9.1 9.2 9.2 9.2 9.2 9.2 9.2 9.2 9. 1 9.1 8.9 8.9 9. 121 9.1 9.1 9.3 9.3 9.4 9.4 9.4 9.2 9.3 9.3 9.2 9.2 9.2 9.3 9.5 9.6 9.7 9.7 9.7 9.6 9.4 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 3.7 3.6 3.6 3.6 3.7 3.9 4.2 4.4 4.5 4.2 3.9 3.7 3.9 3.6 3.4 3.4 3.8 4.4 4.9 5.1 5. 1 4.9 4.5 4.2 4.2 3.9 3.8 3.7 3.7 3.9 4.7 5.6 5.9 5.9 C' C' ..Jo..J 4.9 4.5 4.7 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 22 12-~12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ------------·---------------- 1216/ 11 I 86 Qll21: 121!21 !ZI6 I 1 1 I 86 1212: ~1!21 Y.i6/11 /86 04: 0!!1 Y-i6 / 11/86 i216: 1!1121 j:.~l6i 11/86 08: 1!1121 1!16/11/86 10:0121 1216/11/86 12:1210 1216/11/86 14:0121 06 / 11 I 86 l6: 121~~~ 1!16/11/86 18:@!1 !216/ 11186 21!.1: ~Il0 1~16 I 11 I 86 22: l!l!ll l-?.16 / 12 I 86 1210: 121121 g,l6/ 12186 (?2: 00 1216112/86 1!14: QIIZI 1216/12/86 1216:00 !l16/ 12/86 08: ~i!Zl Y.i6/ 12/86 10: 121121 06/12 I 86 1 2: 0121 1216112/86 14: ~210 12161 12 /86 1 6: e10 ill6/12/86 18:00 Ql6/ 12/86 2121: !21121 (!16/ 12/86 22: 121121 1!16/ 1::\/86 1210:00 !2)6/13/86 1!12:00 Jll6/ 13/86 04: io:1f21 lll61 13/86 1216: 1!1121 1!16/13/86 1218: !210 1216/13186 10:0!ll 1216/13186 12:1!H!I 1216 I 1 3 I 86 14 : s!HZI 1!16113/86 16:00 1216/13/86 18: 1!1!!1 1!16/ 1:3/86 2121: 1211!1 1?.16/13/86 22: !Zll!> BYTE RAW DATA ========== 1521 146 90 1523 145 88 1525 144 87 1527 144 87 1529 144 91!1 1531 145 97 1533 145 103 1535 146 11216 1537 147 106 1539 147 ll!l1 1541 147 96 1543 146 93 DAILY AVERAGE VALUES 1545 146 92 1547 146 91 1549 146 91 1551 145 9121 1553 145 92 1555 146 94 1557 146 99 1559 147 101 1561 147 103 1563 147 11!12 1565 147 99 1567 146 94 DAILY AVERAGE VALUES 1569 146 89 1571 145 86 1573 143 82 1575 143 85 1577 144 90 1579 145 97 1581 147 103 1583 147 105 1585 148 106 1587 148 11!16 1589 148 Hl2 1591 148 98 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 9.6 9.5 9.4 9.4 9.4 9.5 9.5 9.6 9.7 9.7 9.7 9.6 9.5 9.6 9.6 9.6 9.5 9.5 9.6 9.6 9.7 9.7 9.7 9.7 9.6 9.6 9.6 9.5 9.3 9.3 9.4 9.5 9.7 9.7 9.8 9.8 9.8 9.8 9.6 DATA FILE : TREBAR02 START: 04108186 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ====== 4.0 3.8 3.7 3.7 4.0 4.7 5.6 5.6 5.1 4.6 4.3 4.5 4.2 4.1 4.1 4.0 4 " •"- 4.4 4.9 5.1 5.3 5.2 4.9 4.4 4.6 3.9 3.6 3.2 3.5 4.0 4.7 5.3 5.5 5.6 5.6 5.2 4.8 4.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 23 12-Ql2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ----------------===== 06/ 14 /86 121!21 : i!l~l !l/6/14/86 Ql2:l!@ 1!16/14/86 ll14:121!21 ti.!6 I 14 I 86 1!16: 1210 1.!16/ 14 I 86 1!18: !!1121 V.16/14/86 10:t91Zl 1216/14/86 12: !llfll 1216/14/86 14 : !!If! !!16/ 14/86 16: t.'H21 l!i6/l.4/86 18: i!llll (!16/14/86 20: li10 1!16/1.4/86 22: 012i 06/15/86 121121:121121 £16/15/86 02:£10 1216/ 15/86 1!14: 00 1216/15/86 f!l6: 00 Ul6/15/86 {218: 0121 06/15/86 !f!l: 1211.!1 1216/15/86 12: 1!10 !:!16/15/86 14:00 1!16 I 1 5 I 86 16 : 0121 1!16/ 15/86 18:00 !216 / 15/86 20: 121!21 ~16/ 15/86 22: !!1121 Ql6/ 16/86 Q1121: 00 !216/ 16/86 02: 01!1 06 I 16/86 1214: 1!10 1216/16/86 06!12HZi 06/16/86 1!18: 121QI li.l6/i6/86 H!!:l!lli.l 06/16/86 12:0~!1 06/16/86 14: !210 !2!6/ 1. 6/86 16: 0J!i !216/16/86 18:f!l!21 !.!16/ 16/86 2£1: QH!l i2l6/ 16/86 22: !!h!l BYTE RAW DATA -------------------- 1593 148 96 1595 147 94 1597 147 94 1599 147 95 161211 147 97 161!13 14 7 U!ll!l 161215 148 103 1612!7 148 105 1609 149 ll217 1611 150 11217 1613 150 11214 1615 15121 lf!l1 DAILY AVERAGE VALUES 1617 149 98 1619 149 97 1621 148 95 1623 148 94 1625 148 98 1627 15fll uzs7 1629 151 117 1631 153 124 1633 155 125 1635 155 118 1637 156 11121 1639 155 1£13 DAILY AVERAGE VALUES 1641 155 98 1643 153 96 1645 152 95 1647 152 95 1649 151 99 1651 153 108 1653 154 118 1655 155 123 1657 157 123 1659 159 119 1661 16121 113 1663 159 Hl9 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 9.8 9.7 9.7 9.7 9.7 9.7 9.8 9.8 9.9 10. 121 10.0 10.0 9.8 9.9 9.9 9.8 9.8 9.8 10.0 1121. 1 10.3 1f2l. 5 10.5 10.6 10.5 10.1 10.5 10.3 10.2 10.2 10. 1 10.3 10.4 10.5 10.7 Hl. 9 11. !21 10.9 lQl. 5 DATA FILE : TREBAR02 START: 04/08/86 16:00 STOP: 06/18/86 12:06 CHAN 2 DEG C. ------------ 4.6 4.4 4.4 4.5 4.7 5. l!l 5.7 5.7 5.4 5.1 5.0 4.8 4.7 4.5 4.4 4.8 5.7 6.7 7.4 7.5 6.8 6.0 5.7 4.8 4.6 4.5 4.5 4.9 5.8 6.8 7.3 7.3 6.9 6.3 5.9 5.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 24 12-02-87 DATA FILE : TREBARI!I2 BRADLEY LAI<E HYDRO PROJECT START: 1!14/ IllS/ 86 16: 0~1 BRADLEY RIVER -TREE BAR REACH STOP: 1!16/18/86 12: ~l6 CHAN 1 CHAN 2 DATE TIME BYTE RAW DATA DEG c. DEG c. --~--·----===== ----========== ------====== -------------- 1!!6/ 17/86 '-? !Zl : 01!i 1665 158 H!l5 1121. 8 5.5 1!!6/ 17/86 02: ~ll!l 1667 1'56 1!!12 1121. 6 5.2 1!16/ 17/86 fil4: QH!I 1669 154 10e1 H:l. 4 5.0 1!16/17 /86 1!16: 121!21 1671 154 1 !ll1 1£!1. 4 5.1 Ql6/ 17/86 1218: 1!10 1673 154 11!13 11!1.4 5.3 06/17/86 1 k1: 0!!l 1675 154 11121 1.0.4 6.0 1216/17/86 12: 01!1 1677 155 115 10.5 6.5 1!16/ 17/86 14:00 1679 156 114 10.6 6.4 06/17/86 16: 0f!l 1681 156 112 10.6 6.2 !!16/ 17/86 18: IZIV.I 1683 157 109 10.7 5.9 i!l6/ 17/86 2121: l!lf21 1685 156 105 Hi.6 5.5 1!16/ 17/86 22: Y-1121 1687 156 11212 1121. 6 5.2 DAILY AVERAGE VALUES 10.5 5.7 1216/18/86 QI!Zl: 121!21 1689 155 1121121 Ul. 5 5.0 Ql6/18/86 ~12: Ql@ 1691 153 99 l!ll. 3 4.9 1216/18/86 1!14 : 121121 1693 152 98 10.2 4.8 06/18/86 Ql6: liiiZ! 1695 152 99 10.2 4.9 ~!16/18/86 12!8: illl!l 1697 151 1!!10 H1. 1 5. f2l DAILY AVERAGE VALUES Hl.3 4.9 .. '! ~· .... :*. ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER F'age 1 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH BEGII\1 OBS END OBS DATE TIME -------------------------- 1!16/18/86 13:0~!1 ~16/18/86 15:li!f21 Y.l6/ 18/86 17: Ql0 1!16/ 18/86 19: !ZifZI Y.l6/ 18/86 21: l2lfll !216/18/86 23: l!1~?l Ql6/ 19/86 !2H : !21121 !ll6/ 1. 9/86 03: Ql0 !216 I 1 9 I 86 1!15 : !lll21 !216/ 19 I 86 1!17: 0121 1!16/19/86 09:00 f216 I 1 9 /86 11 : 00 !216 I 19/86 13: lllf2l f2S6 I l 9 I 86 15: 0121 Ql6/ 19/86 17: 1210 1216/19/86 19:00 1216/ 1 9 I 86 21 : 121121 es6/19/S6 23:01!1 1?16/2121/86 01: !Zi0 1?.16 I 21!1/86 !213 : Ql0 i216 / 2~!1 I 86 IZI5: 121121 1!16 I 2121 I 86 !217: Y.ll21 fll6/2~~~/86 fll9: 00 !216/20/86 11: I!Hll l!l6/2flJ/86 13:121121 QI6/2J!l/86 15: !!H2l iZ16/20/86 17: (!JJZI ~ZI6/2l21/86 19:1210 ~!l6/21Zl/86 21:00 06/21!1/86 23: £11121 BYTE RAW DATA ==== ========== 1 152 106 3 152 1IZ18 5 153 108 7 153 105 9 153 103 11 152 11.!11 DAILY AVERAGE VALUES 13 151 99 15 150 98 17 148 97 19 148 97 21 148 1£10 23 150 108 25 152 115 27 153 118 29 155 117 31 157 112 33 157 11219 35 156 11l15 DAILY AVERAGE VALUES 37 155 Hl1 39 153 99 41 151 99 43 15~1 99 45 150 11211 47 151 103 49 151 104 51 152 ltl14 53 151 104 55 152 1Y.I4 57 151 11212 59 152 Hll DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 10.2 10.2 lft.l. 3 l{Zl. 3 10.3 10.2 10.3 10.1 U1.0 9.8 9.8 9.8 10.0 H!l. 2 1f21. 3 10.5 10.7 10.7 19.1.6 HI. 2 - 10.5 10.3 l0a1 11!1.121 10.0 lt!i. 1 10.1 10.2 H!l. 1 10.2 10.1 10.2 11ll. 2 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 5.6 5.8 5.8 5.5 5.3 5.1 5.5 4.9 4.8 4.7 4.7 5. Ill 5.8 6.5 6.8 6.7 6.2 5.9 C' C" ""'·""' 5.6 5.1 4.9 4.9 4.9 5.1 5.3 5.4 5.4 5.4 5.4 5 .. 2 5.1 5.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME _____ ., ___ _ --------===== 1.!16/21/86 (!11:!21~1 06/21/86 03: ~lrll 06/21/86 05:~:!1121 f216 I 21 I 86 ll17: fll!21 !216 /21 I 86 !!19: 0!21 06 I 21/86 11 : !Zifll 1216/21186 13:00 !216121/86 15: 121!21 06/21/86 17: Jll~!l 06/21/86 19: 0121 i!i6121 /86 21: 0£!1 ~!16 I 21 I 86 23: 121121 !!16 I 22 I 86 f!l1 : 1!1!21 1216122/86 1213: 121~!5 1!16122186 05: 0121 !216/22/86 07:00 !216 I 22 I 86 09: 1210 06122186 11:00 Y-16/22/86 13:0121 1216/22/86 15: 0t') !216/22/86 17:00 12!6122186 19:00 Y.i6 I 22/86 21 : QIQI il16122/86 23: !21!,21 1216/23/86 l211: 121121 06/23186 03: 1210 06/23/86 1215: (tl~l 06/23186 07: ili121 !216123/86 Y.l9: 0f21 ~~16/23186 11: 0!21 !216/23/86 13: 1.il0 !216123/86 15: 0!~1 1216/23/86 17: IZirll !!16/23/86 1'7!1!11!1 IZ16/23/86 21: f21121 !216/23/86 23:121121 BYTE RAW DATA ========== 61 151 11!11 63 150 10121 65 15!!1 10!21 6 7 1 5fll 1t'l0 69 149 101 71 15121 11213 73 150 1&!14 75 151 1QI4 77 151 105 79 151 lll14 81 151 103 83 151 102 DAILY AVERAGE VALUES 85 151 101 87 151 101 89 151 101 91 151 101 93 15121 11211 95 150 105 97 152 110 99 153 115 101 153 113 103 155 111 1!215 156 109 107 155 105 DAILY AVERAGE VALUES 109 154 102 111 154 Hill 113 153 101 115 153 101 117 152 103 119 153 107 121 153 113 123 154 112 125 155 111 127 155 11!19 129 155 106 131 155 11214 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== llll. 1 1!21. Ill 10.0 1121. !21 9.9 10. Ql 10.0 11!1. 1 10.1 lfll. 1 Ul. 1 HI. 1 10. f21 10.1 10.1 1!21. 1 10.1 10.0 1(1.0 10.2 10.3 10.3 10-5 10.t;? 10.5 1!ZI.2 H1.4 112!. 4 10.3 10.3 1.121. 2 10.3 11:::1. 3 10.4 10.5 10.5 10.5 lY.l. 5 10.4 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: IZI8/06/86 15:07 CHAN 2 DEG C. ====== 5.1 5. t!l 5.121 5. 121 5.1 5.3 5.4 5.4 5.5 5.4 5.3 5.2 5.2 5.1 5.1 5.1 5.1 5.1 5.5 6. l!i 6.5 6.1 5.9 5.5 5.6 5.2 5.1 5.1 5.1 5.3 5.7 6.3 6.2 6. 1 5.9 5.6 5.4 5.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-QI2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ----------------===== 1216/24/86 1!11 : !21!21 !!16/24/86 !!13: f!HZ1 !216/24/86 fll5: 1210 1216/24/86 1217: !!1!!1 1.!16/24/86 09: 0Ql Ql6/24/86 11: 01!1 1216/24/86 13: 0fZI 1216/24/86 15: 01ZI 1216/24/86 17:1210 1216 I 2 4 / 86 1 9 : 121!!1 Ql6/24/86 21: J!l0 !!16/24/86 23: l!h!l 06/25/86 1211: f210 1216/25/86 1!13: 0121 1216/25/86 !215: l!lJ21 ~16/25/86 11.17:(!10 fll6/25/86 !!19: fll0 1216/25/86 11:121121 !!16/25/86 13: 12!121 !216/25/86 15: !ll0 !?16/25/86 17: 0!21 $!16/25/86 19:00 Q16/25/86 21: 01!1 1216/25/86 23: fll0 1216/26/86 1211: 0J!I 1!16/26/86 !213: 0(il !216/26/86 05: !!10 06/26/86 !217: 1£10 1!16/26/86 1219: !!10 12i6/26/86 11: 0J!l ~!16/26/86 13:1210 06/26/86 15:121121 !!16/26/86 17: fll,~l 1!16/26/86 19: !!ifll !216/26/86 21: !Zl!!l 06/26/86 23: 1!1121 BYTE RAW DATA ========== 133 154 lfll2 135 153 Hl1 137 153 11!10 139 152 11Ci1 141 152 103 143 152 11215 145 152 107 147 152 108 149 153 107 151 153 lf!l6 153 153 105 155 153 Hl4 DAILY AVERAGE VALUES 157 152 Hl3 159 152 103 161 152 102 163 152 103 165 152 106 167 152 111 169 154 119 171 156 122 173 157 123 175 158 119 177 158 115 179 158 110 DAILY AVERAGE VALUES 181 158 107 183 157 Hl5 185 156 ll2l4 187 156 U214 189 155 105 191 155 Hil7 193 155 111 195 156 117 197 158 121 199 159 119 2!211 159 118 203 160 115 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 10.4 HI. 3 10.3 HI. 2 Hl.2 lY.I. 2 10.2 10.2 10.3 10.3 10.3 1QI.3 1121. 3 10.2 10.2 1121.2 10.2 HI. 2 10.2 10.4 10.6 1121. 7 1Y.I.8 Hl.E,l 10.8 10.4 10.8 HI. 7 10.6 10.6 1QI.5 10.5 Hl.5 10.6 10.8 1121. 9 HI. 9 11. 121 10.7 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 5.2 5.1 5.0 5.1 .,. ..,. ..Jo..> 5.5 5.7 5.8 5.7 5.6 5.5 5.4 5.4 5.3 .,. ..,. ,J. -\ 5.2 5.3 5.6 6.1 6.9 7.2 7.3 6.9 6.5 6.0 6.1 5.7 5.5 5.4 5.4 5.5 5.7 6.1 6.7 7. 1 6.9 6.8 6.5 6.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 1216/27/86 l!il: !tJQI 1!16 I 27 I 86 !213: 1211!1 ~216/27 /86 !215: 0~!1 1216/27/86 07: 01!1 t36/27 /86 !l19: fll0 1216/27/86 11: 0121 06/27/86 13:1210 1!16/27/86 15:0!21 06/27/86 17:0121 el6/27 /86 19: 1211ZI !ZI6 /27 I 86 21 : Y.IJ!I il.l6/27 /86 23: !21121 06/28/86 !ll1: flSIZI 06/28/86 03:0121 1216/28/86 1!15: 1210 06/28/86 1217: flS0 !216/28/86 !219: 00 {216/28/86 11:00 06/28/86 13: Qlfll 06/28/86 15:00 1216/28/86 17:0121 1216/28/86 19:0121 1216/28/86 21: l!U!I 1216/28/86 23:00 06/29/8~) 1211!00 L;f6/29 /86 03: !210 06/29/86 05:00 1216 I 29/86 £17 : 1210 06/29/86 09:00 !!16/29 /86 11: 12H!I 06/29/86 13: 1!1121 06/29/86 15: 12H21 1!16/29/86 17!!<:1!3 06/29/86 19:1ZHll 1?.16/29/86 21: I!I!Zl !!16 I 29 /86 2 3: i!IIZI BYTE RAW DATA ========== 205 159 110 207 158 1 1215 2!ZI9 157 1 J!l3 211 156 11214 213 156 108 215 156 116 217 158 124 219 159 126 221 161 125 223 162 122 225 162 118 227 163 114 DAILY AVERAGE 229 162 112 231 161 112 233 161 111 235 16£!1 111 237 16121 113 239 160 114 241 16121 115 243 16121 115 245 16(.!1 116 247 161 116 249 161 114 251 161 112 DAILY AVERAGE 253 16121 111 255 159 1 !!19 257 159 109 259 158 1 1219 261 158 111 263 158 114 265 159 120 267 161!1 123 269 161 122 271 163 121 273 163 118 27~· 163 114 DAILY AVERAGE VALUES VALUES VALUES CHAN 1 DEG C. ====== 10.9 lY.I. 8 hl. 7 10.6 Hl.6 1121.6 10.8 Hl.9 11. 1 11.2 11.2 11.3 1121. 9 11.2 11. 1 11. 1 11.0 11. Ill 11.0 11.0 11.0 11.0 11. 1 11. 1 11. 1 11.1 11.0 10.9 10.9 10.8 10.8 10.8 Hl.9 11. 121 11. 1 11.3 11.3 11.3 11.0 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 6. Ill 5.5 5.4 5.8 6.6 7.4 7.6 7.5 7.2 6.8 6.4 ' II: o • ...s 6.2 6.2 6.1 6.1 6.3 6.4 6.5 6.5 6.6 6.6 6.4 6.2 6.3 6. 1 5.9 5.9 5.9 6.1 6.4 7.0 7.3 7.2 7. 1 6.8 6.4 6.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 1.2-~12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 06/3!/.l/86 1!11: 0121 1!16/31!1/86 !213: !21121 IZI6/3Qi/86 05: IlliZi !Zl6 I 3W I 86 1217: fc!l121 9.16/30/86 09:00 !ZI6/3QI/86 11: QIQS IZI6/30/86 13: QSY.I 1216 I 31!1/86 15: 121!21 Ql6/3lll/86 17:0121 06/31!1/86 19:0!ZI !216/30186 21: 00 1!16/30/86 23: 1!1!21 QI7IIZ11/86 1211:1!10 !217/01 186 03: !210 !217 I~~ 1 I 86 1215: 0!21 ~217/1211 /86 1(.17: 00 1!17 /01/86 09:0121 07/01/86 11:0121 1217 /1!11 I 86 1 3: 121!21 07 n::H /86 15: 1210 1217/1211/86 17:121121 !!17 101/86 19:00 t~I7/QI1 186 21: 01!1 Y.l7 /Qil /86 23:00 !217 /1212/86 Q11 : 01!1 07/1212/86 03: I!H!I lll7 11212/86 05: 00 1!17 /IZI2186 07: !211!1 07/1!.12/86 1219: f210 !217 /12'12/86 11: 1!1121 07/02/86 13:!21!21 1217 I 1212/86 15: 121121 07 /!-~12/86 17: 1210 tii7/IZI2/86 19:121121 !?17/!(.!2/86 21:0~t.;s !li7/IZI2/86 23: 01!1 BYTE RAW DATA ========== 277 162 113 279 162 111 281 161 111 283 16!21 111 285 159 113 287 16121 118 289 161 125 291 163 131!1 293 166 130 295 167 126 297 167 12i!l 299 166 116 DAILY AVERAGE VALUES 301 165 114 303 163 113 31215 162 114 3!217 162 114 309 162 115 311 162 116 313 162 117 315 162 119 317 163 120 319 163 119 321 163 116 323 162 112 DAILY AVERAGE VALUES 325 160 110 327 158 109 329 158 111 331 159 113 333 160 114 335 160 114 337 161 115 339 161 117 341 161 117 343 162 117 345 161 114 34 7 1 6fZI 1 12 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 11.2 11.2 11. 1 11.0 1121. 9 11.0 11. 1 11.3 11.6 11.7 11.7 11.6 11.3 11.5 11.3 11.2 11.2 11.2 11.2 11.2 11.2 11.3 11.3 11. ~ 11.2 11.3 11.0 1121.8 10.8 HI. 9 11.0 11. Ql 11. 1 11. 1 11. 1 11.2 11. 1 11. !21 11. Ill DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ====== 6.3 6.1 6.1 6.1 6.3 6.8 7.5 8.0 8. 121 7.6 7.0 6.6 6.9 6.4 6.3 6.4 6.4 6.5 6.6 6.7 6.9 7.0 6.9 6.6 6.2 6.6 6.0 5.9 6.1 6.3 6.4 6.4 6.5 6.7 6.7 6.7 6.4 6.2 6.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-!212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ===== fl/7 /11.13/86 ~31: !ZIJ.!l 1!17 11!13186 !213: !!1!21 !217/!(.13/86 195: 00 !217 /I!!:;; I 86 !217 : 01!! 12!7 n~l3/86 09: J.!il?l !?.17 /!213/86 11: lliQI 1!!7/03186 13: 00 !!l7 11213186 15: 1!1121 f217 1!!.13/86 17:010 1!17 I 1213/86 19: !2!!21 07/1213186 21:00 1!17/1213186 23: 121!21 071~14186 1211:0!21 (217/~:!4/86 03: 0!Zl 1217 I 1!14/86 !215: !21121 07 /lZI4/86 07! 00 !217/1!14/86 1!19: 12a:s 07 /l!14186 11: 0Ql 07/04/86 13: !21~1 07/!214186 15: 0fll 07 I 12!4 I 86 17: !Z!f21 1!17/!!14186 19:00 1!1711!14/86 21:f!l0 l!fl/1!14/86 23:0121 12!7 /1!!5/86 01: 1!10 12!7 11215186 1213: l!l!ZI 1217 l!ll5/86 05: 0Y.I 1!17 I !215/ 86 f:il7: 1210 IZP /1215/86. 1219: 00 !217 /05186 11: 1210 !Zf7 105186 13: 121!!1 1!17 11!!5/86 15:0121 S.!l7 IY-!5186 17: 01!1 1!17 /!215/86 19: 1!1£1 1217/05/86 21:!210 i!l7 1!215/86 23:121121 BYTE RAW DATA ========== 2A9 16f!1 110 351 158 Hl9 353 1 57 1 !218 355 157 1 i2J8 357 157 111 359 158 118 361 159 123 363 161 124 365 162 125 367 163 121 369 164 117 371 163 113 DAILY AVERAGE VALUES 373 162 112 375 161 113 377 161 112 379 160 112 381 161ll 113 383 161tJ 120 385 162 126 387 166 129 389 168 13!.!1 391 169 126 393 168 122 395 167 118 DAILY AVERAGE VALUES 397 165 115 399 163 114 401 163 113 403 162 114 41-115 163 117 407 164 120 41219 164 122 411 166 122 413 166 123 415 167 123 417 166 12(1 419 165 118 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 11.121 1!21. 8 10.7 10.7 10.7 10.8 HI. 9 11. 1 11.2 11.3 11.4 11.3 11.!21 11.2 11. 1 11. 1 11.0 11.0 11 .. !21 11.2 11.6 11.8 11.9 11.~ 11.7 11.4 11.5 11.3 11.3 11.2 11.3 11.4 11.4 11.6 11.6 11.7 11.6 11.5 11.5 DATA FILE : TREBAR03 START: 06118186 13:00 STOP: 08106/86 15:07 CHAN 2 DEG C. ------------ 6.0 5.9 5.8 5.8 6.1 6.8 7.3 7.4 7.5 7. 1 6.7 6.3 6.6 6.2 6.3 6.2 6.2 6 ..,.. • ...> 7.0 7.6 7.9 a. eJ 7.6 7.2 6.8 6.9 6.5 6.4 6.3 6.4 6.7 7.0 7.2 7.2 7.3 --I •...::. 7.0 6.8 6.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TI1'1E -------------------------- 1Zl7/f2i6/86 01:00 1!17./(!16/86 !213: QIV.I IZI7 h!l6/86 fll5: QI!Z! 1!17 /!Zl6 I 86 !217: 01ZI Ql7/l216/86 1219:1210 1217 1Qi6186 11: iil!ll 1.:17 11.!16 I 86 13: 1110 1217 1!!16186 15: IZll!l 1217/06/86 17:00 1!17 I !!16 I 86 1 9: !!JV..I 1217106186 21: 0l2i 1217 11!16/86 23: 0V.I 07 /1!17/86 i21l: 1Zif21 07 I 1!17 I 86 03: 1210 1217 11!17 /86 !215: f21iZl 07 N!17 186 1217: 00 137 1!2i7 /86 IZI9: 0121 1217/1!17 /86 11:00 1l17/IZ!7/86 13:121121 !ZI7 /es7 /86 15:00 V.l7 11217/86 17: IlliZI 1217/1217/86 l. 9: fl.l0 !.':17 I i/..!7 I 86 21 : 1!5!2> 1217/107./86 23: 012! IZ17/QI8/86 01:0!21 Qi7/1218/86 03: !2HZS 07/1218186 1215: 0t.il 07 /IZIB/86 !217: 00 1!17/08/86 1219: 01Zi !217 !(!18/86 1 1 : IZII!l !217 /1!.18/86 13! Qljll 1217 I 1218/86 1 5: IZH21 !Zfl/1218/86 17:00 1!17 I 1218/86 1 9: f!St!l 1217/1218/86 21:0121 ~~17 I 1Zi8 I 86 23: c£1£1 BYTE 421 423 425 427 429 431 RAW DATA -------------------- 165 117 164 116 163 116 163 116 163 117 164 118 165 119 435 165 121 437 166 123 439 166 121 44 1 1 66 12121 443 165 118 DAILY AVERAGE VALUES 445 164 117 447 163 116 449 163 116 451 163 116 453 163 116 455 163 118 457 164 119 459 166 123 461 168 125 463 168 124 465 167 121 467 165 118 DAILY AVERAGE VALUES 469 163 117 471 163 116 473 162 115 475 162 116 477 163 117 479 165 121 48l. 168 124 483 1 7121 127 485 171 127 487 17121 125 489 168 122 491 167 121 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 11.5 11.4 11.3 11.3 11.3 11.4 11.5 11.5 11.6 11.6 11.6 11.5 11.5 11.4 11.3 11.3 11.3 11.3 11.3 11.4 11.6 11.8 11.8 11.-z 11. 5 11.5 11.3 11.3 11.2 11.2 11.3 11.5 11.8 12.121 12.1 12. 121 11.8 11.7 11.6 DATA FILE : TREBAR03 START: 06118/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 6.7 6.6 6.6 6.6 6-7 6.8 6.9 7. 1 7.3 7. 1 7. Ill 6.8 6.9 6.7 6.6 6.6 6.6 6.6 6.8 6.9 7.3 7.5 7.4 7. 1 6.8 6.9 6.7 6.6 6.5 6.6 6.7 7. 1 7.4 7.7 7.7 7.5 7.2 7.1 7.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-!2!2-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME _...._______ ------------------ 1!.17 / 12!9 I 86 01 : 1!1121 1217 /!!19/86 llf3: 0t!l 1217 lk'l9 I 86 f2l5: 01!1 ~!17/1!19/86 Q!7:fZH!I 1!17 I Ql9 I 86 09: 1210 Ql7/lll9/86 11:f{l!!l l!l7/IZI9/86 13:00 t!l7 /1219/86 15: 0fll 07;es9/86 17:00 1217 /1!19 /86 19: 0121 Y.f7 / !219 I 86 21 : !210 07/1Zf9/86 23:121121 f217 I Hl/86 01: 121121 fll7 I 1121 I 86 03: 00 !217 I HI I 86 05: 12HZ! il17/10/86 07:1i.IU1 07 I 1 Ql/86 1219: 1210 1!!7 I l.ill/86 11:00 s!l7 I Hl/86 13:0121 J2l7/l.l!l/86 15:1210 !!17/ 1121/86 17: fi.!0 1217 I HJ/86 19:0121 i!P I HI I 86 21 : f!lfll 1217 I 1!1.1 I 86 23: 0!!1 lli7 /11 /86 01 : 00 !!17/ 11/86 !213: !2112! 1217 I 11 I 86 1215: 0(!1 1!17 I 11 I 86 1217: !£1121 1217/11/86 1219: 00 1217 I 11 /86 11: 12H!1 1217/11/86 13:121~!1 1217/11/86 15:!211!1 !217 / 11./86 1 7: !90 ~!i7 I 1 1/86 1 9 : f!HZI !?.17/11/86 21:1lliZl Y.l7 / 11/86 23: IZI!ll BYTE RAW DATA ---·----------------- 493 166 119 495 166 119 497 165 118 499 165 118 51211 165 120 503 167 123 505 168 125 5f!l7 1 70 127 51219 1 71!1 127 511 170 124 513 169 122 515 167 118 DAILY AVERAGE VALUES 517 166 115 519 164 113 521 163 112 523 162 112 525 162 114 527 163 120 529 165 125 531 167 127 533 168 127 535 169 125 537 168 122 539 167 118 DAILY AVERAGE VALUES 541 166 115 543 164 114 545 164 113 547 163 114 549 163 117 551 164 123 553 169 127 555 171 129 557 17!21 128 559 169 125 561 169 122 563 168 118 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 11.6 11.6 11.5 11.5 11.5 11.7 11.8 12.121 12.0 12.0 11.9 11.7 11.7 11.6 11.4 11.3 11.2 11.2 11.3 11.5 11.7 11.8 11.9 11.1:;! 11.7 11.5 11.6 11.4 11.4 11.3 11.3 11.4 11.9 12.1 12.0 11.9 11.9 11.8 11.7 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ====== 6.9 6.9 6.8 6.8 7.0 7.3 7.5 7.7 7.7 7.4 7.2 6.8 7.2 6.5 6.3 6.2 6.2 6.4 7.0 7.5 7.7 7.7 7.5 7.2 6.8 6.9 6.5 6.4 6.3 6.4 6.7 7.3 7.7 7.9 7.8 7.5 7.2 6.8 7.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME --------------------------er? 1 121s6 ~11: 0121 Ql7 / 12 I 86 1213: Y.SIZI 1217/12 I 86 1215: 121121 !!17 /12/86 !217: I!IY.l \!17/12/86 ~!19:iu;.:. 1!17 I 12/86 1.•.; !cil2l 12!7/12/86 13: I!IY.l \!l > I ·1 2 .·' Ei 6 1. 7 : Qlt!l ;2; / / 1 2 / 86 1 9 : QH!l ~Z> 7 / l.2 / 86 2 1 : Qi~~1 1Zl7 I 13/86 \!1).: !2li?.l ~;:J / / l :~ / ~J.~ ~~i~, ~ 0k:l ,~) 7 ./ 1 :~_:, 1 e.~~ i!) ~J ; ~~ ~> ~-:~-' / .i -~:~ / 6 6 f.?i:;: ~ ;.-~>~!) ~:~: . .,. / _-,, .. ::, ./ E~o 1 :::::: £ih!i i2\-:i / J 3/86 15~. j})f!.j ):: ·:;; I } -... ) / t3t.l J. 7: V.'JQ) r-;~;:· .:· 1 ~·/ t,e:. :; ; ~ tz;,~d .! -../·,_·:,/: ;;tJl:. ";~.,~:. ·_; ~·-+ • t~~ b ~-:, .:~ • ;o ~=-~ ' ' ' j 4 / bt.' ~;l5: 00 ' ' / 14 / .36 !.!17: @21 1Zl7 / 14 I 86 09: IZJIZI (!17/14/86 11 :!!1(!1 Y.f7/14/86 13:!-!10 (!17/14/ 86 15: fZS!ZI 1217/14/86 17:0fll f~l7/14/86 19:QI!ZI Y.l7/14/86 21:12uo l!l7/14/86 23: l!lfZS BYTE RAW DATA ========== 565 166 115 567 165 113 569 163 113 571 1 •':'::::. 114 573 162 117 575 164 121 577 165 126 579 166 127 581 167 125 583 168 122 585 167 121 587 167 121!1 DAILY AVERAGE VALUES 569 !.59 i 59.3 599 6QH 6fi3 6i2i5 166 l. 2~!5 166 1.18 166 117 1.65 118 165 117 165 119 165 121 16;:! 166 122 b). I 1 66 l2~!i f,A I L'r' H ... d::.I"I!"'IGE W~LUES ,:,:; <· 166 119 615 165 117 617 164 115 619 164 115 621 164 117 623 164 124 625 167 132 627 17!21 141 629 177 148 631 177 145 633 177 141 635 178 137 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 11.6 11.5 11.3 11. :;:r. 11.2 11.4 11.5 11.6 11.7 11.6 11.7 11.? .11 • 5 11.6 11.6 l1. 6 11.5 11.5 11. 5 1 1. !:J 11.5 u .. c 11.6 ..... .i. .t • I_ 11.6 11.6 11.6 11.5 11.4 11.4 11.4 11.4 11.7 12.0 12.7 12.7 12.7 12.8 11.9 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15. CHAN 2 DEG C. ·----·-------- 6.5 6. ::. 6.4 6.7 7. 1 7.6 7.7 7.5 ... , 0 I o 1 "7. ~~ .~ .• ·=; 6.8 . -, e. , 6.8 ,s. 7 6.9 / • 1 7. ~2 ... "7;" I • ·-·• • .L . 7.1 7.0 7. as 6.9 6.7 6.5 6.5 6.7 7.4 8.2 9.1 9.8 9.5 9.1 8.7 7.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 V.l 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ========= ---------- 1217/15186 01:1210 1217 I 15/86 1213:0121 !217 i 15/86 1!15: 1210 £!7/15/86 1!17: 01!1 i!l7 / 15/86 !219: 121121 k':l7 / 15/86 11: 121121 1217 I 15/86 13:00 !ZI?/15/86 15:121£1 !217 /15/86 1"7: 00 Q17 /15 I 86 19: 1210 07/15/86 21:00 1217/15/86 23: 12l1Zl lil7/16186 !!11: 0{11 i:!l7 I 16/86 03: 0121 Ql7 I 1 6 l 86 !!15: f2l1Zl Y-17/16/86 07:00 1!17/16/86 09:0J!S 1217/16/86 11: 4!10 1217/16/86 13:0~<:1 1217/16186 15:00 f217 I 16/86 17: 01!1 1!17/16/86 19:121!21 (!17/16/86 21:1210 IZ17 I 16/86 23: J!l0 !217/17/86 1!11: 00 1217/1 7/86 1!13: !21~1 1217/17/86 1215:00 1!17 /1 7 I 86 07: !21121 07/1 7/86 1219: 0121 Y.17 117/86 11: 0121 1217 .I l. 7/86 13: 0!ll !::17 I 17/86 15:0121 !!Fl./ 17/86 17:1210 1!1"7 / 1 7 /86 1 9 : !ll!ll !!17/17 /86 21:121121 !217 I J. 7/86 23: 1.!1121 BYTE RAW DATA -------------------- 637 178 135 639 177 133 641 177 132 643 176 132 645 176 131 647 176 133 649 176 134 651 177 135 653 177 135 655 177 134 657 177 133 659 177 131 DAILY AVERAGE VALUES 661 176 131 663 176 130 665 175 129 667 175 128 669 175 129 671 175 131 673 174 13121 675 175 130 677 174 13121 679 174 129 681 174 126 683 173 124 DAILY AVERAGE VALUES 685 171 121 687 17121 119 689 169 117 691 168 117 693 167 120 695 168 125 697 171 131 699 175 134 71211 176 135 71213 174 131 705 172 127 7lll7 1 7ll1 124 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 12.8 12.7 12.7 12.6 12.6 12.6 12.6 12.7 12.7 12.7 12.7 12.7 12.7 12.6 12.6 12.5 12.5 12.5 12.5 12.4 12.5 12.4 12.4 12.4 12.3 12.5 12.1 12.0 11.9 11.8 11.7 11.8 12.1 12.5 12.6 12.4 12.2 12.0 12.1 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ====== 8.5 8.3 8.2 8.2 8.1 8.3 8.4 8.5 8.5 8.4 8.3 8.1 8.3 8.1 8. i!l 7.9 7.8 7.9 8.1 8.0 8.0 8. 121 7.9 7.6 7.4 7.9 7.1 6.9 6.7 6.7 7.0 7.5 8.1 8.4 8.5 8.1 7.7 7.4 7.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11 12-1212-87 ~RADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ===== !2!7 / 1. 8/86 01: 0121 !!17 / 18/86 !213: !l1Y.l ~:17 /18/86 05: £1!!1 1217 I 18186 e-17: 1!1121 1217/18186 ~19: 0121 !.(17/18186 11: !21121 Ql7 I 18186 13:00 1217118/86 15:012"1 1217/18186 17:00 1!17 I 18/86 19: 00 07 I 18/86 21:0121 S!l7/18/86 23:1210 07/1 9 /86 01 : r!Htl !!17 I 19186 03: V.J0 1217 I 1 9 I 86 05: 1210 1217/19/86 07: f2l£1 1!17 I 19/86 09: f!IY.I 1217/19/86 11:00 tZ17/19186 13: 012! 1217 I 19/86 15: 00 1217/1 9 I 86 1 7: ~1121 1217/19/86 19: Y.Hll t!S7 I 19/86 21: !ZlQI ~!17 /19/86 23: 01!1 9.1712121186 01:1-!11!1 !217 I 21.!1 I 86 !!13: 1210 1217 I 2121 I 86 1215 : 00 1217 I 20 I 86 ~£17 : f21t21 1!17/2!!1186 Y.l9: 00 Y.l7/2!!.1186 11: 121121 l!l7 /212.1/86 13: 00 07/21!1186 15: Qll21 1!17120/86 17:00 Y-"17 /29.1/86 19:121121 1?.17 /2121/86 21 : l!10 1217/20/86 23: 0121 BYTE 709 711 713 715 717 719 RAW DATA ========== 168 167 167 166 167 169 121 12121 121 121 123 127 721 172 132 723 174 135 725 174 134 727 173 131 729 172 129 731 17V.I 126 DAILY AVERAGE VALUES 733 170 124 735 169 122 737 168 121 739 168 121 741 168 123 743 169 131 745 172 136 747 176 140 749 178 140 751 177 136 753 176 134 755 176 136 DAILY AVERAGE VALUES 757 177 137 759 177 137 761 177 137 763 178 137 765 178 139 767 179 14121 769 18121 142 771 18f21 142 773 18~~~ 142 775 181 141 777 18121 138 779 178 135 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 11.8 11.7 11.7 11.6 11.7 11.9 12.2 12.4 12.4 12.3 12.2 12. 121 12.rll 12.0 11.9 11.8 11.8 11.8 11.9 12.2 12.6 12.8 12.7 12.l:} 12.6 12.2 12.7 12.7 12.7 12.8 12 .. 8 12.9 13.0 13.0 13.0 13. 1 13. Ill 12.8 12.9 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 7.1 7. Ill 7. 1 7. 1 7.3 7.7 8.2 8.5 8.4 8. 1 7.9 7.6 7.7 7.4 7.2 7. 1 7.1 7.3 8.1 8.6 9. 121 9.0 8.6 8.4 8.6 8. i!l 8.7 8.7 8.7 8.7 8.9 9.0 9.2 9.2 9.2 9.1 8.8 8.5 8.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 12 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ===== 1217/21/86 fll1: Ql£1 (217 /21/86 !213: !211!1 !217 /21/86 1215:100 1!17 /21/86 07:01:11 07/21/86 09:00 1217/21/86 11:0121 07/21/86 13:00 07/21./86 15:00 07/21/86 17: f21Ql !217/21/86 19:1211£1 Ql7 /21/86 21: !1J0 1!17 /21 I 86 23: 121121 1~17 /22/86 01:00 fi.S7 /22/86 V.13: f2lj_/l ~<:17 /22/86 !215: 01!1 07/22/86 ~17:00 07/22/86 1219:0121 IZ17 /22/86 11: 00 !217 /22/86 13: !ZI0 ll17 /22/86 15: fll0 1!17 /22/86 1 7: 0fZI 07/22/86 19:00 1217/22/86 21:0{2'1 07/22/86 23: 0.el 1217/23/86 01: 00 1217/23/86 1213: QI!ZI 1217/23/86 05:00 1!17 /23/86 1!17: QHZI 1!17/23/86 109:00 Ql7 /23/86 11: !21fll 07/23/86 13a!ll!l !217/23/86 15: !lSIO 07/23/86 17:00 Ql7 /23/86 19: !Zl!21 !217 /23/86 21: 00 iZ17 /23/86 23: 1211!1 BYTE RAW DATA =========== 781 178 133 783 177 132 785 176 1310 787 175 129 789 174 129 791 175 134 793 175 137 795 176 138 797 177 136 799 177 137 801 178 137 81213 177 136 DAILY AVERAGE VALUES 805 178 139 807 179 144 81219 179 142 811 179 141 813 180 142 815 180 142 817 18f21 142 819 181 142 821 181 142 823 181 142 825 181 141 827 1 8121 1 39 DAILY AVERAGE VALUES 829 180 138 831 179 137 833 180 138 835 178 138 837 178 138 839 1 77 14fil 841 179 143 843 181 145 845 181 145 847 182 144 849 182 142 851 182 141 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 12.8 12.7 12.6 12.5 12 .. 4 12.5 12.5 12.6 12.7 12.7 12.8 12.7 12.6 12.8 12.9 12.9 12.9 13.0 13 .. 0 13.0 13.,1 13.1 13.1 13.~ 13.0 13.121 13.0 12.9 13.0 12.8 12.8 12.7 12.9 13.1 13.1 13.2 13.2 13.2 13.0 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 8.3 8.2 8. ~1 7.9 7.9 8.4 8.7 8.8 8.6 8.7 8.7 8.6 8.4 8.9 9.4 9.2 9.1 9.2 9.2 9.2 9.2 9.2 9.2 9 .. 1 8.9 9.1 8.8 8.7 8.8 8.8 8.8 9.0 9.3 9.5 9.5 9.4 9.2 9. 1 9.1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 13 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ===== IZ17 /24 i 86 !211 : !:'J!Zl P..i7 I 2 4 / 86 !!'3: !.!1121 1217/24/86 1215: 0l::l i!i7 /24/86 !217: 1!11!1 £17/24/86 fll9: I!H·!I 1!17/24/86 11:0~t1 !217 /24/86 13:00 !!17 /24/86 15: 01!1 07/24/86 17:00 1217/24/86 19: fih21 07/24/86 21:1210 07/24/86 23: 1!10 Y.l7 /25/86 l!Jl : 0121 07/25/86 03:00 1217/25/86 1215: 0!!1 1217/25/86 !217: i-!H~I 1217/25/86 1219:00 07./25/86 11: 01!1 1!17/25/86 13: 00 07/25/86 15:00 07/25/86 17:00 !!17/25/86 19:00 1!17 /25/86 21: !210 ~?7 /25/86 23:0121 !217 /26/86 01: 0i21 1217/26/86 1!13: 121121 07/26/86 05:00 £17/26/86 07: 1!10 ~17/26/86 1!19: 121121 1217/26/86 11: 0121 i217/26/86 13:0!21 !!17/26/86 15: IZH!I 1217/26/86 17: 121121 1217/26/86 19:0121 07/26/86 21: !Zh!l 1217/26/86 23: !210 BYTE RAW DATA ========== 853 182 139 855 181 137 857 180 136 859 179 135 861 179 135 863 179 135 865 18121 137 867 181 138 869 181 136 871 179 132 873 178 130 875 177 127 DAILY AVERAGE VALUES 877 176 127 879 176 1.29 881 176 130 883 176 132 885 177 134 887 178 137 889 179 138 891 180 137 893 18!t1 137 895 181 135 897 181 135 899 182 134 DAILY AVERAGE VALUES 901 181 133 9QI3 181 133 905 181 133 907 181 133 91219 181 133 911 181 137 913 182 14!!1 915 184 142 917 185 141 919 186 138 921 184 132 923 182 127 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 13.2 13.1 13.121 12.9 12.9 12.9 13.0 13.1 13 .. 1 12.9 12.8 12.7 13 .. 0 12.6 12.6 12.6 12.6 12.7 12.8 12.9 13.0 13.121 13.1 13.t 13.2 12.9 13.1 13.1 13.1 13.1 13.1 13.1 13.2 13.4 13.5 13.6 13.4 13.2 13.2 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: IZ18/Ill6/86 15: (!17 CHAN 2 DEG C. ------------ 8.9 8.7 8.6 8.5 8.5 8.5 8.7 8.8 8.6 8.2 8.0 7.7 8.5 7.7 7.9 e. 121 8.2 8.4 8.7 8.8 8.7 8.7 8.5 8.5 8.4 8.4 8.3 8.3 8.3 8.3 8.3 8.7 9. Ill 9.2 9.1 8.8 8.2 7.7 8.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPDD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER P.age 14 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ------.. -------------------- Q17/27/86 QI1:0QS ~Zl7 /27/86 i!l3: 1Zif21 1217/27/86 05:Y.Hll i217 I 27/86 !!17: ~21121 ·07 /27/86 Ql'i!: 1210 1217/27/86 11:1211!1 !217/27/86 13:1210 1!17 I 27 I 86 15: f21l2i 1217/27/86 17:00 1217 I 27/86 19: 0121 07/27/86 21:00 1217/27/86 23:1210 1217/28/86 1211: 00 07/28/86 03:0121 1217/28/86 fll5: !ZII21 1217/28/86 07:00 1217/28/86 1219: 12lJ!I Y.l7 /28/86 11: 00 !217/28/86 13:f2lf21 1!!7/28/86 15:00 (!17/28/86 17:0121 1217/28/86 19:1210 !217 /28/86 21: 1211!1 121'7 /28/86 23: 01:!1 07/29/86 i!l1: 0!21 !217 I 29 /86 1!13: i!!f.ZI t!17 /29/86 05: 00 1217/29/86 07: 0fll !!17 I 29 I 86 09: 12H21 r217 I 29/86 11: 121!21 1217/29/86 13: 0t21 1217/29/86 15: f2U21 07/29/86 1. 7: 121!21 ~!17 /29/86 19: !21121 (!17/29/86 21:1210 !217 /29/86 23:0121 BYTE RAW DATA -------------------- 925 18ft.! 125 927 178 124 929 177 123 931 176 123 933 175 125 935 176 130 937 178 135 939 18121 1 38 941 182 138 943 183 136 945 182 132 947 181 13121 DAILY AVERAGE VALUES 949 181 128 951 179 127 953 179 126 955 178 127 957 178 129 959 179 134 961 183 142 963 186 147 965 188 148 967 191 146 969 191 143 971 1 9 1 14121 DAILY AVERAGE VALUES 973 190 137 975 190 136 977 188 135 979 188 135 981 188 136 983 188 141 985 190 147 987 192 151 989 194 151 991 195 148 993 196 145 995 195 142 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 13. 121 12.8 12.7 12.6 12.5 12.6 12.8 13. f21 13.2 13.3 13.2 13.1 12.9 13.1 12.9 12.9 12.8 12e8 12.9 13.3 13.6 13.8 14 .. 1 14.1,. 14.1 13.4 14.0 14.0 13.8 13.8 13.8 13.8 14.0 14.2 14.4 14.5 14.6 14.5 14.1 DATA FILE : TREBAR03 START: 06/18/86 13!00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ------------ 7.5 7.4 7.3 7.3 7.5 8.0 8.5 8.8 8.8 8.6 8.2 8. l!l 8.0 7.8 7.7 7.6 7.7 7.9 8.4 9.2 9.7 9.8 9.6 9.3 9.0 8.6 8.7 8.6 8.5 8.5 8.6 9.1 9.7 10.1 Hl.1 9.8 9.5 9.2 9.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 15 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME --------------------------- !ZI7 /30/86 1!11: 1210 Y.l7 I 30/86 1!13: 121£1 1217/30/86 ~15: ~10 i!17 I 3121 I 86 07: i!S!ZI 1!!7 /3f!l/86 1219:00 1!!7 /3121/86 11: 12H21 1217/30/86 13:00 07/30/86 15: QIIZI !217/30/86 17:00 1217/30/86 19alf!l ll17/30/86 21: J!H!1 Y.I7/31ZJ/86 23: rMl 07/31/86 £11:0121 07/31/86 1213: 121fll Y.i7/31 /86 !l15: 0C11 07/31/86 07:00 1£17/31/86 09: 1211!1 12J7/31/86 11:00 1217 /31/86 13: t!H!I 07/31/86 15:00 !217/31/86 17:0121 £17/31/86 19: 1210 Qf7 /3 1 I 86 21 : 0121 !217/31/86 23:121121 1!18/1211/86 i!ll: !21121 !218/i!.si /86 03:00 !218/1211/86 05:00 C!I8/IZI1 /86 !217: 0f21 !218hH /86 f219a~0 !218/!211 I 86 11 : lllf21 f!IS/1!11 I 86 13: 10121 08/01/86 15: 12H21 £18/ 12!1/8 6 1 7 : ~1121 08/01./86 19:01£1 1218/1211/86 21 : l!li!l 1218/ ull/86 23: 121121 BYTE RAW DATA ========== 997 194 14fll 999 193 139 112101 192 139 1 12103 1 92 138 lf2h'l15 1 9 1 14121 1007 192 144 1009 193 148 112H 1 1 95 1 51 1013 196 149 1{2115 196 145 1017 195 143 1019 194 141 DAILY AVERAGE VALUES 112121 193 139 1023 193 138 1025 192 138 1@27 191 138 1029 191 140 1031 191 141 1033 192 145 1'!135 1 93 148 1037 195 148 lf2139 1 95 146 1!2141 195 143 1043 194 141 DAILY AVERAGE VALUES 1045 194 139 1047 193 139 1049 193 139 Hl51 192 139 1053 192 140 1055 192 144 1057 194 148 Hl59 195 148 11.!161 196 146 1fZI63 195 145 112165 195 143 H!l67 194 142 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 14.4 14.3 14.2 14.2 14.1 14.2 14.3 14.5 14.6 14.6 14.5 14.4 14.4 14.3 14.3 14.2 14.1 14. 1 14.1 14.2 14.3 14.5 14.5 14.5 14.4 14.3 14.4 14.3. 14.3 14.2 14.2 14.2 14.4 14.5 14.6 14.5 14.5 14.4 14.4 DATA FILE : TREBAR03 START: 06/18/86 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ====== 9.0 8.9 8.9 8.8 9.0 9.4 9.8 HI. 1 9.9 9.5 9.3 9. 1 9.3 8.9 8.8 8.8 8.8 9.0 9.1 9.5 9.8 9.8 9.6 9.3 9.1 9.2 8.9 8.9 8.9 8.9 9.0 9.4 9.8 9.8 9.6 9.5 9.3 9.2 9.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 16 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ----------------===== 1!18/1212/86 !!11: Y.lfl Ql8/i!l2/86 !213: !ZI~l iZl8h7.12/86 1215: 00 !218 I !!12 I 86 1217 : ~>1!1 1-;19/ !!12/86 1!19: 0121 !218/!212/86 11: 1210 &!18/ !i.l2 I 86 1 ::;.\: 121!21 1218/1!12/86 15: 0121 I218/IZI2/86 17:00 08/!!12/86 19:121121 j.}IS/1112/86 21:00 1218/!!12186 23:121£!1 08/!!13/86 !!11: 121121 08/1!13/86 kl3: 0121 1218/!!13/86 05: !ZI!Zl Y.l8/V.I3186 07: 00 V.l8/i!l3/86 1219:0121 ~18/!!13/86 11: 0~3 1218/03/86 13: 1!10 1218/1!13186 15:00 f218/Y.I3/86 17: 1211!1 f-!18/1213/86 19:0121 !.!18/!!13/86 21: 0!!1 08/!!13/86 23:00 Q/8/1214186 1.!11: 00 !ZI81!!14186 12)3: 1!1121 081al4186 05:00 08 I 1214/86 1217: 01ll 08 I 04 /86 1219: 0fll 08 I 1!14 / 86 11 : 1!1!!1 08/04/86 13:00 1218 I !!14 /86 15: 121121 08h~l4/ 86 17: 1!1,? 1218/1214/86 19: 121{21 1218/1214/86 21: 12Ho !!i8/!Zl4/86 23: 01!1 BYTE RAW DATA ========== Hl69 194 141 112171 194 141 Hl73 193 141 1075 193 141 1077 193 142 1079 193 144 11'2181 194 146 lel83 1 94 15121 1085 195 150 1087 196 146 112189 1 95 143 1091 194 142 DAILY AVERAGE U!193 194 141 Hl95 194 142 112197 194 142 1099 193 142 1101 193 144 1 Hl3 194 144 1105 193 144 1 Hl7 193 144 111!19 193 146 1111 194 145 1113 193 143 1115 191 142 DAILY AVERAGE 111 7 1 9121 143 1119 191 143 1121 19121 142 1123 189 142 1125 190 143 1127 192 146 1129 194 148 1131 196 147 1133 195 146 1135 194 144 1137 193 143 1139 192 142 VALUES VALUES DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 14.4 14.4 14.3 14.3 14.3 14.3 14.4 14.4 14.5 14.6 14.5 14.4 14.4 14.4 14.4 14.4 14.3 14.3 14.4 14.3 14.3 14.3 14.4 14.3 14.1 14.3 14.0 14.1 14.0 13.9 14.0 14.2 14.4 14.6 14.5 14.4 14.3 14.2 14.2 DATA FILE : TREBAR03 START: 06/18/86 13!00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ====== 9. 1 9. 1 9.1 9. 1 9.2 9.4 9.6 10. "' 10.0 9.6 9.3 9.2 9.4 9.1 9.2 9.2 9.2 9.4 9.4 9.4 9.4 9.6 9.5 9.2 9.3 9.3 9.2 9.2 9.3 9.6 9.8 9.7 9.6 9.4 9.3 9.2 9.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page i7 12-1?12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- 1218/1215/86 1211: 01!1 t!1811!15/86 !Zl3: !!1121 !c:l81!!l5/86 Q15! 00 !218/!?!5/86 1217: 121~1 1218/1215/86 09: 00 Ql8/l!l5/86 11: 0!!1 l218/f!l5/86 13:00 081(215/86 15: 0!ll 08n.':l5186 17:00 08/S!I5/86 19:0121 QI8/QI5/86 21:0121 {!18/!!15/86 23:0121 1218/1216186 1!11: 121(!1 J!l8 I Ql6 I 86 !213: 0!21 !21811!16/86 1215: f!SV.I Ql8 I Qi6 I 86 1217: 0lll Y.I8/Sll6186 !219:1210 Y.l81fll6/86 11:0121 t.if8/lil6 /86 13: fil0 BYTE RAW DATA ========== 1141 193 142 1143 192 141 1145 193 141 1147 192 140 1149 193 142 1151 194 143 1153 196 145 1155 196 145 1.157 196 145 1159 196 143 1161 194 142 1163 194 141 DAILY AVERAGE VALUES 1165 193 140 1167 192 139 1169 191 137 1171 191 137 1173 192 139 1175 194 142 1177 195 143 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 14.3 14.2 14.3 14.2 14.3 14.4 14.6 14.6 14.6 14.6 14.4 14.4 14.4 14.3 14.2 14.1 14.1 14.2 14.4 14.5 14.3 DATA FILE : TREBAR03 START: 06118186 13:00 STOP: 08/06/86 15:07 CHAN 2 DEG C. ====== 9.2 9. 1 9. 1 9.0 9.2 9.3 9.5 9.5 9.5 9.3 9.2 9.1 9.3 9.0 8.9 8.7 8.7 8.9 9.2 9.3 9.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 1 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 BEGIN OBS :CHANNEL 1= 14.6 CHANNEL 2= 9.6 AT 18:07 0 ERRORS END OBS :THE PROBES WERE WASHED OUT ON ABOUT 8/27/86 -PULLED THE POD DATE TIME ----------------===== 08/1216/86 17:00 IZI8/I!l6/86 19: !ZIIZI 08/1!16/86 21:00 08/1!16/86 23:00 i!l8/07 /86 !211 : !2Hll !!18/£17 /86 03:00 V.181 1!17 I 86 1215: !!1121 !218/12!7/86 1217: 01!1 1218/!217 /86 09: 0!21 1118/107/86 11:00 08/1!17 /86 13:121121 fll8/1~17/86 15:0121 08/1217/86 17: {21!21 !218/ 1!17 /86 1 9 : !210 ~!18/1217/86 21: !21121 1218/1217/86 23: l!lfll 1218/08/86 1211: 0121 1!18/1!18/86 03:0121 !218h~8/86 05: 0V.l i~l8/!218/86 07:00 08/Y.I8/86 1219:00 !218/1218/86 11:121£21 !218/!!18/86 13:0fll {!18/!218/86 15:00 1218/~18/86 17:00 i!l8/08/86 19:00 1218/1218/86 21:00 1!18/1218/86 23: f2l0 1!18/!219/86 01:!21111 1118/11.19/86 ~13:1210 1218/ 1~19 I 86 1215: 1!1!21 08/!219/86 (!17: 1210 1!18/1219 I 86 1219: 1!11!1 11.18/09/86 11:1!10 08/1219/86 13:1210 £!18/09/86 15: 00 1!18/1!19/86 17: i!l!ZI 08/1219/86 19: 1!10 1218/1!19/86 21:V.If21 Ql8/09/86 23: Y.H!I BYTE RAW DATA ========== 1 197 145 3 199 147 5 199 147 7 198 145 DAILY AVERAGE VALUES 9 198 144 11 197 143 13 197 142 15 196 141 17 19c 141 19 196 142 21 196 143 23 197 143 25 197 143 27 197 143 29 196 142 31 196 141 DAILY AVERAGE VALUES 33 195 139 35 194 139 37 194 138 39 193 138 41 193 137 43 193 138 45 194 142 47 196 143 49 197 143 51 196 142 53 196 141 55 195 140 DAILY AVERAGE VALUES 57 194 139 59 194 139 61 194 139 63 194 139 65 194 139 67 194 140 69 195 141 71 196 143 73 197 143 75 196 142 77 196 14!!1 79 195 139 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 14.7 14.9 14.9 14.8 14.8 14.8 14.7 14.7 14.6 14.6 14.6 14.6 14.7 14.7 14.7 14.6 14.6 14.7 14.5 14.4 14.4 14.3 14.3 14.3 14.4 14.6 14.7 14.6 14.6 14.5 14.5 14.4 14.4 14.4 14.4 14.4 14.4 14.5 14.6 14.7 . 14.6 14.6 14.5 14.5 CHAN 2 DEG C. ------------ 9.5 9.7 9.7 9.5 9.6 9.4 9.3 9.2 9.1 9.1 9.2 9.3 9.3 9.3 9.3 9.2 9.1 9.2 8.9 8.9 8.8 8.8 8.7 8.8 9.2 9.3 9.3 9.2 9.1 9.0 9.121 8.9 8.9 8.9 8.9 8.9 9 .IZI 9. 1 9.3 9.3 9.2 9. I.Zl 8~9 9. ill ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 2 12-!!12-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- 1:'18 / 1 ,!1/86 Ql1 : fllflJ i!18/1!21/86 ~!13: 1.!1~1 fll8/ 11!1/86 1215:00 {:~18/10/86 f!17: Q!fll 1!18/10/86 09: 00 '!18/ Hl/86 11:0121 lll8 l Hll 86 13: 1!10 1218/10/86 15: 1!1121 Y.IS/10/86 17: !.!1IZI 1!18/1121/86 19: 1!1€1 l!i8/ 1 fll/86 21: fli0 !218/ 11!1/86 23: IZIY.I 1218/11/86 1!11 : ese1 fl.l8/11/86 1!13: I!IY.I vJ8/11/86 f2S5: Y.lfll J-~18/11 /86 07: 00 !218/11 /86 1219: 0121 1218/11/86 11: f210 1!18/11/86 13:!21121 1218/11/86 15: 0\il 1!18/11/86 17:00 1218/11/86 1 9: 00 1218/11/86 21:00 1218/11/86 23: fll(il 08/12/86 01:00 1218/12/86 1213: IllY.! QIS/12/86 Q15: 00 l!l8/12/86 1217:f21121 1!18/12/86 09:1210 fil8/12/ 86 11 : flliZI 1!18/12/86 13:0121 !218/12/86 15:0121 !218/ 12/86 17: 0l(J !!18/ 12/86 19: 1!10 1218/12/86 21: Y.h!l 1!18/12/86 23: 121!21 BYTE RAW DATA ========== 81 194 139 83 194 139 85 194 138 87 193 139 89 192 139 91 192 140 93 193 141 95 195 143 97 197 145 99 198 145 101 198 143 1Qi3 197 142 DAILY AVERAGE VALUES Hi5 196 140 107 195 139 11219 194 138 111 194 138 113 194 138 115 193 138 117 193 139 119 195 140 121 195 140 123 196 140 125 195 139 127 194 136 DAILY AVERAGE VALUES 129 192 135 131 192 136 133 192 136 135 192 137 137 193 137 139 193 137 141 193 139 143 194 14!.!1 145 195 140 147 196 141 149 195 140 151 194 138 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 14.4 14.4 14.4 14.3 14.2 14.2 14.3 14.5 14.7 14.8 14.8 14.7 14.5 14.6 14.5 14.4 14.4 14.4 14.3 14.3 14.5 14.5 14.6 14.5 14.4 14.5 14.2 14.2 14.2 14.2 14.3 14.3 14.3 14.4 14.5 14.6 14.5 14.4 14.3 DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ======= 8.9 8.9 8.8 8.9 8.9 9. {.!l 9.1 9.3 9.5 9.5 9.3 9.2 9.1 9.0 8.9 8.8 8.8 8.8 8.8 8.9 9.0 9.0 9.0 8.9 8.6 8.9 8.5 8.6 8.6 8.7 8.7 8.7 8.9 9. r21 9.0 9.1 9. r2! 8.8 8.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 3 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ===== Ql8/13186 1211:00 1218113186 1!13: !~JI!l 1218/13186 05: 121(!1 f!l81 13186 !ll7: Qj~j ~18 I 13186 Y.l9: Ql0 1218113186 11: 00 08/13196 13:00 i!18/ 13/86 15: 0~1 08/13/86 17:!210 ~:?8113/86 19:12i121 1218113/86 21:00 1!18/13/86 23:012! 08114186 01:121(21 £18/14186 03:00 1!18 I 14 I 86 1215: 1211!1 1218/14/86 07:09.1 1218/14/86 1!19: 00 {!18/ 14/86 11: 00 !218 I 14 I 86 1 3: IZH21 1218/14/86 15:00 Y-18/ 14/86 17: 00 081 14/86 19: 0fll 1218 I 1 4 I 86 21 : 0121 08/14186 23:1210 1!18/ 15/86 1211: 1210 !218/ 15186 f!l3: l!llll £!8/ 15/86 1!15: 00 1218115186 fll7: fll0 !!18115/86 09:1!10 !218 I 15 I 86 1 1 : 121121 1218/15186 13:00 1218/15186 15:00 12181 15/86 17: 0QI 1!181 15/86 19: 1211!1 08115186 21: Y.lfiJ 1!18 I 15/86 23: !!lit! BYTE RAW DATA ========== 153 193 136 155 193 136 157 192 134 159 19121 131 161 187 128 163 185 127 165 185 128 167 186 130 169 187 13121 1 71 186 1312! 173 186 129 175 186 128 DAILY AVERAGE VALUES 177 185 128 179 185 129 181 186 129 183 186 129 185 186 129 187 186 131 189 188 133 191 189 135 193 191 136 195 192 137 197 192 136 199 192 135 DAILY AVERAGE VALUES 201 192 136 21213 1 92 1 35 205 191 135 207 191 134 2f219 190 134 211 190 134 213 19121 135 215 191 137 217 192 138 219 192 138 221 193 137 223 192 135 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 14. ;:.~ 14.3 14.2 14. fll 13.7 13.5 13.5 13.6 13.7 13.6 13.6 13.6 13.8 13.5 13.5 13.6 13.6 13.6 13 .. 6 13.8 13.9 14. 1 14.2 14.~ 14.2 13.8 14.2 14.2 14.1 14.1 14.0 14.121 14.0 14.1 14.2 14.2 14.3 14.2 14.1 DATA FILE : TREBAR04 START: 08106/86 17:00 STOP: 10101/86 12:00 CHAN 2 DEG C. ====== 8.6 8.6 8.4 8~ 1 7.8 7.7 7.8 8.0 8.0 a. tti 7.9 7.8 8.1 7.8 7.9 7.9 7.9 7.9 8.1 8.3 8.5 8.6 8.7 8.6 8.5 8.2 8.6 8.5 8.5 8.4 8.4 8.4 8.5 8.7 8.8 8.8 8.7 8.5 8.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 4 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 1218/1.6/86 !211: 121~!1 08116186 1!13: fliY.I 08/16186 05:1!1!21 08/16/86 1217: l!ll21 !218/16/86 09: fliQI i!18 I 16 I 86 11 : l!lf21 1!18/16/86 13!00 08/16/86 15: 1!1121 08/16/86 17:00 Q18/ 16186 19: ~1{¢:1 f2!81 16/86 21: lc!1!21 !2!8/16/86 23!1!1121 I!J81 17/86 01: !'210 08/17186 1213: fl!0 08/17186 !215: !2H2i !2!8/ 17/86 1217: 00 1!18117/86 09:0121 1!18/17/86 11:00 !218 I 1 7 I 86 1 3: 00 1218/17./8615:00 08/17186 17:1!1!21 fll8/17/86 19:00 !!181 17/86 21: 012! 9.!8/ 17/86 23:00 08/18/86 llll: 0121 08118186 03: 1!1~1 08/18/86 05:00 08/18/86 lc!17: 121121 1218/18/86 09: 0QI !218/18/86 11:01!1 !218/18/86 13: 1!}0 !218 I 1 8 I 86 1 5 : 121121 1218/18/8617:00 1!18/18/86 19:1!HZS 08/18/86 21: fllf_i) !218 I 18/86 23: 1!1!21 BYTE RAW DATA ==== -------------------- 225 192 135 227 191 134 229 1 9121 1 34 231 189 132 233 189 132 235 189 133 237 190 136 239 192 14121 241 195 142 243 195 14121 245 194 136 247 192 132 DAILY AVERAGE VALUES 249 19121 129 251 187 127 253 185 125 255 184 125 257 184 125 259 184 127 261 185 133 263 189 140 265 193 143 267 196 143 269 195 140 271 194 137 DAILY AVERAGE VALUES 273 193 135 275 192 135 277 191 135 279 191 136 281 191 137 283 192 138 285 192 138 287 192 139 289 193 140 291 194 141!1 293 194 14~c!1 295 194 139 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 14.2 14. 1 14.0 13.9 13.9 13.9 14.0 14.2 14.5 14.5 14.4 14.2 14. 1 14.0 13.7 13.5 13.4 13.4 13.4 13.5 13.9 14.3 14.6 14.5 14.4 13.9 14.3 14.2 14.1 14.1 14.1 14.2 14.2 14.2 14 .. 3 14.4 14.4 14.4 14.2 DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 8.5 8.4 8.4 8.2 8.2 8.3 8.6 9. e1 9.2 9. Ql 8.6 8.2 8.5 7.9 7.7 7.5 7.5 7.5 7.7 8.3 9.3 9.3 9.0 8.7 8.3 8.5 8.5 8.5 8.6 8.7 8.8 8.8 8.9 9. "' 9. Ql 9.0 8.9 8.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 5 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- QIS/ 19/86 1211: 1211!1 1218/19/86 1213: !Zl!ZI !1.18/ 19/86 ~!15: ~!10 !218/ 1 9 I 86 1217: 1!1!21 08/ 19/86 09: 121!21 1218/19/86 11:00 08/19/86 13:fZI0 1!18/ 19/86 15: 1!1!21 !218/ 19/86 17: 1210 l!l8 I 1 9 I 86 1 9: 121121 !!18/ 19/86 21: 1211ZI 1!18/ 19/86 23: 121121 08/2!!1/86 01: 0121 !218/2IZI/86 1213:00 !218/2!21/86 1!15: IZIQI 08/2Y.1/86 07: 00 !218 I 2!21 I 86 1219: Qlel 1218/2121/86 11: 00 1218/2121/86 13: !21{21 f~8/20/86 15:1210 Ql8/2i!i/86 17: 01!1 08/ 2J!I I 86 1 9 : 0!21 1!18 I 2~!l I 86 21 : 0121 (!18/21?!/86 23: 0!!l 08/21/86 1211: 012! !218 I 21 I 86 !213: 121!21 1218/21/86 05: 121121 1218/21/86 1!17:1ZIIZl 1218/21 I 86 09: 121121 i!l8/21 /86 11: IZl!Zl 12!8/21 /86 13: l21l!l 1!18/ 21 I 86 15: !.!1121 08/21/86 17:wJl!l 08/21. I 86 1 9: !21!!1 1!.18/21/86 21:!21121 1!18/21 /86 23: !!IJZI BYTE RAW DATA -------------------- 297 194 138 299 193 138 301 193 138 303 193 138 31tJ5 1 93 138 307 193 138 309 193 141 311 195 145 313 197 146 315 197 145 317 197 142 319 196 14!ZI DAILY AVERAGE VALUES 321 323 327 329 331 333 335 337 339 341 195 139 194 139 193 138 193 138 192 137 192 138 193 143 196 149 199 152 2!211 151 21!11 148 343 21211 145 DAILY AVERAGE VALUES 345 199 143 347 197 141 349 195 138 351 194 137 353 193 136 355 192 137 357 193 142 359 195 148 361 199 151 363 21211 148 365 20!21 142 367 196 138 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 14.4 14.3 14.3 14.3 14.3 14.3 14.3 14.5 14.7 14.7 14.7 14.6 14.5 14.5 14.4 14.3 14.3 14.2 14.2 14.3 14.6 14.9 15. 1 15.1 15. 1 14.6 14.9 14.7 14.5 14.4 14.3 14.2 14.3 14.5 14.9 15. 1 15.121 14.6 14.6 DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ 8.8 8.8 8.8 8.8 8.8 8.8 9. 1 9.5 9.6 9.5 9.2 9.0 9. 1 8.9 8.9 8.8 8.8 8.7 8.8 9.3 9.9 HI. 2 1121. 1 9.8 9.5 9.3 9.3 9. 1 8.8 8.7 8.6 8.7 9.2 9.8 Hl.1 9.8 9.2 8.8 9.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 6 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -·------------------------- 08/22/86 !211: 00 1218/22/86 ill3: !2112'1 1.!18/22/86 1!15: 0!!1 1258/22/86 ~17: !ZIIZl Y-18/22/86 1219:00 f218/22/86 11:00 08/22/86 13: 01ZI 08/22/86 15:0121 Y.l8/22/86 17: 0f21 ~18/22/86 19:1210 Ql8/22/86 21: 121!3 !!18/22/86 23:12H?I !!18/23/86 01: 0!21 1218/23/86 !213: ~10 08/23/86 (215: 0!ll Y-18/23/86 07:00 !218/23/86 !219: 0f21 1!18/23/86 11: 0121 08/23/86 13: ~lQI 1,~18/23/86 1.5:@21 1218/23/86 17: !!1121 !!18/23/86 19: 1()0 !218/23/86 21:0121 1218/23/86 23:00 1218/24/86 1211:00 fZIS/24/86 Ql3: 1'21!!1 08/24/86 05:0121 1218/24/86 07: 1'21121 1218/24/86 09:00 !218/24/86 11: 0!21 !218/24/86 13:00 !!18/24/86 15: lZI!ll 08/24/86 17:1.!1~1 1218/24/86 19: !!H~I 08/24/86 21: IZIQI !!>8/24/86 23: 0!ll BYTE RAW DATA -------------------- 369 194 135 371 192 136 373 191 135 375 191 135 377 19J!I 134 379 19Cl.l 134 381 190 135 383 190 136 385 ·191 139 387 192 139 389 193 138 391 192 136 DAILY AVERAGE VALUES 393 190 134 395 189 133 397 188 132 399 187 132 4!211 187 134 4!213 189 137 405 191 138 41217 192 139 4!219 193 141 411 193 141 413 194 141 415 194 141!1 DAILY AVERAGE VALUES 417 193 140 419 193 139 421 193 139 423 193 139 425 193 139 427 193 139 429 194 142 431 196 145 433 198 148 435 199 147 437 198 145 439 197 143 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 14.4 14.2 14.1 14. 1 14.0 14. !ZI 14.0 14.0 14.1 14.2 14.3 14.2 14.1 14.0 13.9 13.8 13.7 13.7 13.9 14. 1 14.2 14.3 14.3 14.4 14.4 14.1 14.3 14.3 14.3 14.3 14.3 14.3 14.4 14.6 14.8 14.9 14.8 14.7 14.5 DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 8.5 8.6 8.5 8.5 8.4 8.4 8.5 8.6 8.9 8.9 8.8 8.6 8.6 8.4 8.3 8.2 8.2 8.4 8.7 8.8 8.9 9.1 9.1 9. 1 9.0 8.7 9. !Zl 8.9 8.9 8.9 8.9 8.9 9.2 9.5 9.8 9.7 9.5 9.3 9.2 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 7 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE T II'1E ----------------===== !218/25/86 i!l1: 0121 !218/25/86 1213: 1!1121 1218/25/86 05: 1!10 !218 I 25 I 86 07 : 121121 1218/25/86 09: 00 !218/25/86 11:121121 !218/25/86 13: Ql0 08/25/86 15: Y.l£1 1218/25/86 17:01ll !218/25/86 19:121121 !218/25/86 21:00 f-18/25/86 23: 01ll !218/26/86 flll: 0!21 Ql8/26/86 03: 00 1218/26/86 05: Y.H!i 1218/26/86 07:00 !!18 I 26 I 86 1!19: 1.!1121 U18/26/86 11: 0121 1!18/26/86 13:121121 !118/26/86 15:00 1!.18/26/86 17:0121 12)8/26/86 19:1.!10 €18/26/86 21: 0QI !218/26/86 23:00 1218/27/86 ~'11: 0121 1218/27/86 !213: 121121 08/27/86 1215: w.IIZl 1218/27/86 1217: 0!c!l IZIS/27 /86 IZ19: QIIZI 1!18/27 /86 11: 0fll !218/27/86 13:1210 !218/27 /86 15:1210 !218/27 /86 17:00 !218/27 /86 19: 0!21 QIS/27 /86 21: Qll!i !!18/27/86 23: QIY.I BYTE RAW DATA -------------------- 441 196 142 443 195 141 445 195 141 447 194 14121 449 193 140 451 193 14121 453 194 141 455 194 141 457 195 142 459 195 143 461 195 141 463 194 141 DAILY AVERAGE VALUES 465 1 93 14121 467 194 140 469 194 14121 471 193 14Ul 4 73 1 93 14121 475 193 140 477 193 141 479 193 142 481 193 142 483 194 142 485 193 143 487 193 144 DAILY AVERAGE VALUES 489 192 144 491 193 153 493 190 151 495 187 167 497 187 166 499 189 164 5rcH 16121 164 51213 97 162 51215 1!212 0 5!!17 125 !3 509 125 0 511 122 Ill DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 14.6 14.5 14.5 14.4 14.3 14.3 14.4 14.4 14.5 14.5 14.5 14.4 14.4 14.3 14.4 14.4 14.3 14.3 14.3 14.3 14.3 14.3 14.4 14.~ 14.3 14.3 14.2 14.3 14.f21 13.7 13.7 13.9 11.0 4.7 5.2 7.5 7.5 7.2 10.6 DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ====== 9.2 9.1 9. 1 9. !21 9.0 9. !21 9. 1 9. 1 9.2 9.3 9.1 9.1 9.1 9.0 9. 121 9. !21 9.0 9. 121 9. 121 9. 1 9.2 9.2 9.2 9.3 9.4 10.3 11!1. 1 11.7 11.6 11.4 11.4 11.2 -5. !21 -5. {c!l -5. Ql -5. f2j 5.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 8 12-1212-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME -------------------------- 1118128/86 01:00 !218/28/86 !1:13: I!IQ! !218/28186 05: 121!1.1 1!18/28/86 fll7: 0fll 1218/28/86 09: 12H21 1218128/86 11: 121121 1218/28/86 13:00 1218/28/86 15: 0!.!1 08/28/86 17: !ZIQI 1!18128186 19: 121!21 08/28186 21: 1210 i..if8/28/86 23: 121~1 ,218129/86 flll: 00 08129/86 1213:00 !ll8/29 I 86 1215: !211.!1 1.!18/29186 !217:0121 !218/29/86 09: IlliZI i!18/29/86 11:J!H21 Y.IS/29186 13: IZI0 Y.IS/29/86 15:1210 1218/29/86 17:0121 08/29/86 19:0121 !218/29/86 21: 121!21 1218/29/86 23: 00 f218/3i!S/86 !lll: .1210 !218 I 3V.l I 86 !213: 121121 ~18/30/86 1215:00 1218/31!1/86 07: 01!1 1!18130/86 1!19: 1210 !!18 / 31Zi /86 11 : 1!1121 !ll8/31l.l/86 13:0121 Y.I8/3Y.I/86 15: 1!11!1 08/30/86 17:00 !Zl8 I 3!!1 I 86 1 9: 121121 1218/ 3!!1 /86 21 : !21121 1!18/3l!l/86 23: 0QI BYTE RAW DATA -------------------- 513 119 0 515 114 0 517 111 0 519 108 J!l 521 105 0 523 105 0 525 11216 0 527 105 0 529 105 0 531 103 0 533 102 0 535 101 Ill DAILY AVERAGE VALUES 537 11ZI0 !21 539 98 121 541 97 l.il 543 96 0 545 96 0 547 96 121 549 96 0 551 96 0 553 95 Ill 555 94 0 557 93 121 559 92 0 DAILY AVERAGE VALUES 561 92 0 563 92 0 565 91 121 567 91 0 569 91 0 571 92 0 573 94 121 575 96 Ill 577 97 0 579 96 0 581 94 f21 583 93 121 DAILY AVERAGE VALUES CHAN 1 DEG C. ====== 6.9 6.4 6.1 5.8 C' C" ...Jo...J 5.5 5.6 5.5 5.5 5.3 5.2 5.1 5.7 5. 121 4.8 4.7 4.6 4.6 4.6 4.6 4.6 4.5 4.4 4.3 4.2 4.6 4.2 4.2 4. 1 4.1 4 •. 1 4.2 4.4 4.6 4.7 4.6 4.4 4.3 4.3 DATA FILE : TREBAR04 START: 08/06/86 17:00 STOP: 10/01/86 12:00 CHAN 2 DEG C. ------------ -5.0 -5.0 -5.1!5 -5. f!l -5.0 -5.0 -5.0 -5.0 -5.0 -5. Iii -5.!il -5. 121 -5.1!1 -5.0 -5.0 -5. J!l -5. ~~ -5.121 -5.0 -5.!il -5.0 -5.0 -5. III -5.121 -5. Ill -5.0 -5.0 -5.121 -5. Iii -5.0 -5.0 -5. Iii -5.0 -5.0 -5.0 -5.0 -5. !21 -5. !21 -5.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 9 12-02-87 BRADLEY LAKE HYDRO PROJECT BRADLEY RIVER -TREE BAR REACH DATE TIME ======== ---------- 1!18 r:. 1 186 1211 : rz1121 i!l8/31 /86 1!13: !!lV.l Ql8/~51 /86 !Zl5: 00 !218 I 31 I 86 !Zl7: !!1121 !218 / :;:: 1 I 86 !Zl9: !!1121 1218/31186 11:1ZHZI 1'::18/31. 186 13: !ZIQI (18 I 31 I 86 1 5: !ZIIZI !218/31186 17:1ZJI!I QiS/31186 19:!Zl!ZI !218131/86 21:0121 1218/31186 23: !21121 i!l9 I !Zi 1 I 86 V.l1 : l!l!Zl 1219/1211/86 1213: 121!21 12!9 / !Zl1 /86 1215: Ql(il !219 /!21 1/86 !217: 1210 1219/ IZi 1 l 86 1!19: 121121 1219/01. I 86 11 : f2J!Zl !219 h!ll I 86 13: 121121 1219/01/86 15: 12l!Zl !!19 I V.l 1 I 86 1 7: !Zll2l 09 / 01 I 86 1 9: Qll!l !219 I Y.l1 /86 21 : 121121 !Zi9 / !Zll. /86 23: 0121 11191!212/86 (.211: I!J0 Ql9 /1212186 !!13: !21!21 Ql9/lt.l2/86 1215:00 1!19 1!212/86 12!7: Ql!Zl Y.l9 I 1212/86 1219: 00 1219/1!12186 11: !Zl0 1.2l9/lil2/86 13: 1!10 !219 Nl2 I 86 15: !!H2l 12i9 h~l2/86 17: IZl!Zl fl9 / !Ii2 /86 1 9: i!l~l 1!19/ i!l2 /86 21 : '!li!.l Qi9 / (12 /86 23: !~lQl BYTE RAW DATA -------------------- 585 93 121 587 93 !!l 589 93 0 591 93 !!S 593 92 !Zl 595 93 121 597 94 0 599 95 0 61211 97 0 61213 98 121 61215 97 .0 6!217 97 121 DAILY AVERAGE VALUES 6!219 611 613 615 617 619 621 623 625 627 629 95 Y.l 93 121 93 {!l 94 0 93 0 93 l!l 96 0 HH 0 1 !Zl!Zl Ql 98 121 97 121 631. 95 121 DAILY AVERAGE VALUES 633 94 0 635 94 !!S 637 94 0 639 94 0 641 94 121 643 95 121 645 97 Ql 647 99 IZl 649 1~%1 0 651 101 fZl 653 99 !Zl 655 99 121 DAILY AVERAGE VALUES CHAN 1 DEG C. ------------ 4.3 4.3 4.3 4.3 4.2 4.3 4.4 4.5 4.7 4.8 4.7 4.7 4.5 4.5 4.3 4.3 4.4 4.3 4.3 4.6 5.1 5. 121 4.8 4.7 4.5 4.6 4.4 4.4 4.4 4.4 4.4 4.5 4.7 4.9 5. 121 5.1 4.9 4.9 4.7 DATA FILE : TREBAR04 START: 08106186 17:00 STOP: 10101/86 12:00 CHAN 2 DEG C. ------------ -5. 121 -5. 121 -5. Ill -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5. !Zl -5.0 -5.0 -5. 121 -5.121 -5.0 -5. (il -5.0 -5. 121 -5. 121 -5 .Ill -5.0 -5. !Zl -5. 121 -5.0 -5. 121 -5.0 -5. Ql -5. 121 -5.0 -5. !Zl -5. {!1 -5.121 -5. Ql -5. !ZI -5.0 -5.121 -5. 121 -5.!21 -5. !Zl ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP212 V6-0.1 DEG C TEMP/TEMP RECORDER Page 11!1 12-1212-87 DATA FILE : TREBAR1!14 BF<ADLEY LAKE HYDRO PROJECT START: 1!18/l,!16/86 1 7: 1!1121 BRADLEY RIVER -TREE BAR REACH STOP: 1121/1!11/86 1 2: IZil!l CHAN 1 CHAN 2 DATE TIME BYTE RAW DATA DEG c. DEG c. -·--···------· ---------------------- --------------------------------------------- ~~19 /1!13/86 V.l 1 : 1!10 657 11!11 (!I 5. 1 -5.0 1219 /1!13/86 iZI3 : 1!1121 659 11211 1!1 5. 1 -5. 121 1!19/C!I3/86 1!15: 1!1~1 661 101 1!1 5.1 -5. 1!1 1~19 h:l3/86 1217: !Zifll 663 11!11 1!1 5. 1 -5. 1!1 1219 h:l3 / 86 IZI9: i!IQI 665 111.11!1 0 5. 121 -5. ,~1 !!19 /1213/86 11 : i!HZI 667 1121!!1 I! I 5. 121 -5. 12i I.!J9/I!I3/86 13: 1210 669 11211 0 5.1 -5.0 1219/1213/86 15: 121121 671 104 !!1 5.4 -5. 121 1219/03/86 17:00 673 Hl6 0 5.6 -5. ~I i219/!ZI:::;; /86 19: 1!11!1 675 11216 1!1 5.6 -5. IZI IZ19/1213/86 21: 0121 677 11214 0 5.4 -5. 121 i219/Qf3/86 23: 1!1121 679 11213 121 c:-..,.. ~. _, -5. 121 DAILY AVERAGE VALUES 5.2 -5. IZI 121'=1 I 1!14 I 86 IZI1 : 121 !21 681 102 121 c:-..., ..Ja.L. -5. 121 09/1214/86 03: 1!11!1 683 101 ~!I 5.1 -5. Ql !!19/1214/86 1215: 19121 685 10121 0 5. 121 -5.0 1?.19/1214/86 1217: 01!1 687 1 1211!1 {ZI 5. {l1 -5.0 !!19/04/86 1219 : i!ll21 689 99 121 4.9 -5.0 1219 I 1214/86 11 : 121121 691 99 !ZI 4.9 -5.0 1!19/1214/86 13: 121121 693 11211 0 5.1 -5. !c!1 1.!19/1214/86 15: 1!1121 695 105 0 5.5 -5.0 1219/1!14/86 1 7: iZII21 697 11217 I! I 5.7 -5 .Ill 09/1214/86 1 9: 1!1121 699 11218 I:! I 5.8 -5. Ill 1!19/1214/86 21: 01!1 71!11 11!16 !c!1 5.6 -5. 1!1 ATTACHMENT Ill NORTH FORK BRADLEY RIVER ALAS!< A POWER AUTHORITY TEMP/STAGE STUDIES Page 1 DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER 12-!213-86 DATA FILE NFORI<QI1 BRADLEY LAI<E HYDRO PROJECT START: 12/28/85 11: QIQI NORTH FORI< OF BRADLEY RIVER STOP: ~11 /1!18/86 !!19: 1211!1 STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 G0= 1-il G1= 0 G2= Ill BEGIN OBS :NO COEFFICIENTS WERE AVAILABLE -DISCHARGE NUI'lBERS NOT ACCURATE END OBS :NO END DATE/T IJviE WAS RECORDED -LOOKED AT RAW DATA TO DETERMINE ~ .,. J. I DEPTH STAGE DISCHG TEMP DATE TIME BYTE RAW DATA MV INCHES IN. CFS DEG c ======== ---------========== ---------------====== ===== ---------------- 12/28/85 11 : 0£1 1 52 106 10.4 20.8 2!!l. 80 Ql 3.0 12/28/85 17:1!10 3 50 107 10. !ZI 2lit. i!l 20. 1211!1 121 3.5 12/28/85 23:1210 ... ;;;} 49 107 9.8 19.6 19. 6f2l 0 3.5 DAILY AVERAGE VALUES 2121. 13 {21 3.3 12/29/85 1215: !210 7 47 106 9.4 18.8 18.80 0 3. Qt 12/29/85 11:00 9 45 106 9.0 18.0 18. 0f2! f.! I 3. Q~ 12/29/85 17:00 11 44 106 8.8 17.6 17.60 $21 3.0 12/29/85 23: I!I!Zl 13 43 106 8.6 17.2 17. 2{21 !ZI 3.0 DAILY AVERAGE VALUES 17. 91!1 lll 3. t!J 12/3121/85 1215:00 15 42 107 8.4 16.8 16.80 \21 3.5 12/30/85 11:00 17 41 107 8.2 16.4 16.40 121 3.5 12/3Ql/85 17: Qf0 19 40 106 8.0 16.0 16. 0!21 121 3. i!l 12/30/85 23: !210 21 39 105 7.8 15.6 15.6!Zl Ql 2.5 DAILY AVERAGE VALUES 16. 21!1 I! I 3. 1 12/31/85 1!15: 00 ...,-:- ,4..,.) 38 105 7.6 15.2 15.20 IZl 2.5 12/31/85 11: !Zl0 25 37 1fll5 7.4 14.8 14. Sill !ZI 2.5 12/31/85 17: 01!1 27 37 105 7.4 14.8 14.8121 i!l . ., c.• k•'-' 12/31/85 23: QIIZI 29 36 104 7.2 14.4 14. 4121 (!I 2. Y.l DAILY AVERAGE VALUES 14.8$21 0 2.4 i91 I Y.l1 I 86 !!15: 0121 31 35 1!214 7. l!l 14.1.!1 14. Ill!!! Ill 2. !!l I.(Jl/QH /86 11:00 33 34 105 6.8 13.6 13. 6lll Y.l 2.5 1211/01/86 1 7: IZlfZl 35 33 105 6.6 1""' ..., '"'•"" 13.20 0 2.5 01/01/86 23: QJ0 37 31!1 104 6.0 12. k1 12.0121 0 2.0 DAILY AVERAGE VALUES 13. 2!!1 !21 2.3 01 /~!12/86 05: 0121 39 27 104 5.4 10.8 10. 8liJ 0 2. ~!I i211 /!ll2/86 11 : !Zl!ZI 41 27 104 5.4 10.8 10.80 0 2. i!l 01/1!12/86 17: Qf0 4 .... ..::. 25 104 5. Ill 1Jll. 0 11!1. Y.l0 0 2. IZI 01 /!212/86 23: lllf!l 45 28 104 5.6 11.2 11. 21ZI Ill 2. 1!5 DAILY AVERAGE VALUES 10.7121 0 2.0 ~n /IZI3/86 !!15: l!lt2l 47 30 11214 6.0 12.1ZI 12. 1210 l!l 2. l!l !211 /03/86 11 : !210 49 43 104 8.6 17.2 17.20 0 2. ~!I !!l1 /03/86 17:00 51 95 1 !215 19.1ZI 38. 1!1 38. 01!1 fc!l ,., C" ..::...\J !ll1/03/86 23:00 53 116 105 ...,-:-..., ""-"-' . ...:.. 46.4 46. 4!!1 0 2.5 DAILY AVERAGE VALUES 28. 4Ql (!! 2.3 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES Page .., .... DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEI'1P. RECORDER 12-f!l3-86 DATA FILE NFORI<01 BRADLEY LAKE HYDRO PROJECT START: 12/28/85 11: (!10 NORTH FORK OF BRADLEY RIVER STOP: 1!11 /!218/86 09: !211!1 STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 G0= 0 G1= f!l G2= SZI DEPTH STAGE DISCHG TEMP DATE TIME BYTE RAW DATA MV INCHES IN. CFS DEG c ------------------------------------------------===== ---------------------------------------- k!l1 /Jil4/86 05! lllQI 55 95 1~?15 19.0 38.0 38.00 Ill 2.5 01/1214/86 11 : 121121 57 85 Hl6 17.0 34. IZI 34.1Zl0 0 3. Ql !Zl1 /04/86 1 7: 12lf21 59 83 106 16.6 33.2 33. 21!1 !ZI 3. Y.l !!11 /1!14/86 23: IZIQI 61 76 106 15.2 30.4 30. 4k1 Ill 3. Ql DAILY AVERAGE VALUES 33.90 0 2.9 01/QIS/86 IZ15: 0121 63 70 H16 14.0 28.0 28.00 (!I 3.0 j{Jl /!!15/86 11:00 65 66 Hl6 1 .... ,., -'•"-26.4 26.40 IZI 3. 121 i!i1/05/86 1 7: l!lfll 67 60 106 12.0 24.1ZI 24. fllf!l Ill 3.0 Y.ll/1!15/86 23: 1210 69 57 11215 11.4 22.8 22.80 IZI 2.5 DAILY AVERAGE VALUES 25. 31!1 e1 2.9 i!ll/i!l6/86 05: 01!1 71 54 105 10.8 21.6 21.60 0 2115 1211/1!16/86 11:1210 73 51 105 19.1. 2 20.4 2121.40 0 .., C' .-.. • ...J Y.ll/QI6/86 17!00 75 48 105 9.6 19.2 19.20 0 2 .. 5 IZll I 1216/86 23: IlliZI 77 46 11215 9.2 18.4 18. 41ZI 0 2.5 DAILY AVERAGE VALUES 19.90 Y.l 2.5 1!11/1~17/86 1!15: 1!10 79 45 105 9.0 18.0 18.0121 0 2.5 1!11 /l!.l7/86 11:00 81 42 104 8.4 16.8 16.80 0 2.0 011!?.!7 /86 1 7: llll!l 83 41!1 11214 e. e1 16.0 16. 01!1 0 2.0 ~~1/f217/86 23:00 85 39 104 7.8 15.6 15.60 Ql 2. Ql DAILY AVERAGE VALUES 16.6121 Ql 2. 1 01/08/86 1.!15: 0121 87 37 104 7.4 14.8 14.80 0 2. 1!1 1!11/08/86 11:00 89 34 11!14 6.8 13.6 13.60 Ql 2. i!l 12>1 /1!18/86 17:00 91 33 105 6.6 13.2 13. 2i21 f!l 2.5 1211/IZIS/86 23:1210 93 34 11.!14 6.8 13.6 13.60 f.! I 2. 1!1 DAILY AVERAGE VALUES 13.80 l!i 2.1 i2ll I 1!19/86 05:00 95 33 104 6.6 13.2 13. 2$!1 0 2. Ql I!H /!?.19/86 11: 1210 97 34 104 6.8 13.6 13.60 0 2. Ql !2l1/!ll9 186 1 7: 1!11!1 99 35 11!14 7.0 14.f!l 14.00 0 2. 121 1211/1!19 /86 23:00 11!11 33 104 6.6 13.2 13.20 121 2.0 DAILY AVERAGE VALUES 13.50 i!l 2. !!l 1~11/ l $!1 I 86 05: 1210 103 32 104 6.4 12.8 12.8121 Ql 2. Y.l ~!.il/1 !Z~ /86 11 : !21121 19.15 31 1!215 6.2 12.4 12.40 0 "'j C"' Lo...J (!11 I 1121/86 17: 0.V.I 107 31 11Zl4 6.2 12.4 12.40 l?l 2.1!1 1211 I 11!1 /86 23: 1!1121 11219 30 11214 6. !21 12.!21 12. !Zif2l 0 2. f!l DAILY AVERAGE VALUES 12. 4!'1J !!l 2. 1 1!11 I 11/86 !215: i!H!l 1 1 1 3(!1 1 !!14 6. i!l 12. Y.l 12. 121!21 k1 2. l?l !21 1/ 11/86 11 : i!ll21 113 30 105 6.121 12.0 12. 1210 121 ,., C' , • ..J !!11/11 /86 1. 7: @21 115 29 lt215 5.8 11.6 11. 6121 I! I 2.5 01/11/86 23: l!S0 117 29 11214 5.8 11.6 11. 6~1 fll 2.0 DAILY AVERAGE VALUES 11. 8!!1 Y.i 2.3 ALAS!< A POWER AUTHORITY TEMP/STAGE STUDIES Page 3 DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER 12-1213-86 DATA FILE NFORI<01 BF<ADLEY LAI<E HYDRO PROJECT START: 12/28185 11 : 1!10 NORTH FORI< OF BRADLEY RIVER STOP: iH /1218/86 !!19: 1210 STAGE=DEPTH+G0 DISCHG=G1+(DEPTH+G0)AG2 Gf!J= 0 G1= 0 G2= 0 DEPTH STAGE DISCHG TEI"'P DATE TIME BYTE RAW DATA MV INCHES IN. CFS DEG c ======== ===== -·-------------==== ------------------------------------------------------ !211 /12186 1215:0121 119 28 11215 5.6 11.2 11. 2V.i 0 2.5 Ql1 /12186 1 1 : t!l!.!l 121 29 U!'l5 5.8 11.6 11. 6QI Ill 2.5 i!l1/12186 1 7: I!H!i 123 31!1 105 6. ~~ 12.0 12.00 0 2.5 !!11 I 12/86 23: (2Jj2t 125 29 1QI5 5.8 11.6 11.60 0 2.5 DAILY AVERAGE VALUES 11.60 1!1 2.5 01113/86 05: !!10 127 28 105 5 .. 6 11.2 11.20 1!1 2.5 01/13186 11 : 1210 129 27 Hl6 5.4 10.8 10.80 121 3.0 !!11 I 13/86 17: 01ll 131 27 106 5.4 11!1.8 HI. 8121 0 3.0 ~~11 /13/86 23:00 1~~ ........ 27 106 5.4 10.8 10. 8121 121 3. IZ! DAILY AVERAGE VALUES 10.90 0 2.9 !211/14/86 05:00 135 27 11216 5.4 10.8 1121. 80 0 3.0 1211 I 14/86 11:00 137 27 U!l6 5.4 10.8 HI. 81!1 Ill 3. Ql 1211114186 17: !210 139 28 Hl6 5.6 11.2 11.20 Ill 3. Ql (!11/14/86 23: 0121 141 27 U!l6 5.4 10.8 10.80 Ill 3. fll DAILY AVERAGE VALUES 10.90 121 3. Ill 1!11/15/86 1215: !!10 143 26 106 5.2 10.4 10.40 121 3.0 1211/15/86 11:00 145 26 Hl6 5.2 10.4 10.40 !21 3. fli i211 I 15/86 17: 1!50 147 25 106 5.0 10.0 1121.00 0 3. 121 ~H/ 15/86 23:0121 149 24 106 4.8 9.6 9. 6!21 0 3. flj DAILY AVERAGE VALUES HI. 1121 !!I 3. kl . !211/16/86 05: 1!1121 151 24 1 {215 4.8 9.6 9. 6!!1 0 .-, c::" "'-•w 12>1 /16/86 11 : !21121 153 24 11!15 4.8 9.6 9. 6121 0 2.5 01/16/86 17:00 155 22 1t!l4 4.4 8.8 8. 8121 !21 2. 1!1 !!ll/16/86 23: !!I ill 157 20 11214 4. ~~ a. 121 8. 1!1121 0 2. Ql DAILY AVERAGE VALUES 9. I'OS!I 0 2.3 01/17/86 05:00 159 19 1!214 3.8 7.6 7. 6Y.I 0 2.0 1211/17/86 11: lll0 161 21 104 4.2 8.4 8.40 Ql 2.0 k:11 I 1. 7/86 1 7: 1!11!1 163 22 11215 4.4 8.8 8. 8tZI V.l 2.5 Qil/17 /86 23: 01ll 165 22 1!214 4.4 8.8 8.80 !Zi 2.0 DAILY AVERAGE VALUES 8.40 121 2. 1 £'11/18/86 05:00 167 ~..,.. "'" .... ' 1t!l4 4.6 9.2 9. 21!1 0 2. 1!1 Qll/18/86 1 1 : 121!21 169 22 11!14 4.4 8.8 8.80 1!1 2. !?I !!11/18/86 17:00 171 21 104 4.2 8.4 8.40 Ql 2. Ill !211/1.8/86 23: t!lQl 173 21 1 !214 4.2 8.4 8.40 0 2. QS DAILY AVERAGE VALUES 8. 7121 l~i 2. Q! Y.i1 I 19/86 {215 : 1!11!1 175 2!!1 1Ql4 4. 121 8. Ill 8. 1!10 !Zl 2. r2l 1!11 /19/86 11 : Y.l0 177 20 Hl5 4.0 8 .1!1 8. 1210 !Zl 2.5 !M /19/86 17: 1!10 179 18 1£:15 3.6 7.2 7.20 I.! I 2.5 e11 119/86 23: Ql0 181 18 H!l5 3.6 7.2 7. 2!21 tc:l 2.5 DAILY AVERAGE VALUES 7. 6121 121 2.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMF'. RECORDER Page 4 12-1213-86 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*CDEPTH+G0)AG2 Gl21= 0 DATE TIME ======== ---------- 1211/20/86 1!15: 00 01/2121/86 11:0t!l !211 /2!!1/86 17: 0121 i!ll I 21!1 I 86 23: 121121 01/21186 05:1!1121 k'H/21/86 11:1l1fll 1211/21/66 17: !!IV.! !211 I 21 I 86 23: 0QI 01/22186 1215: !210 !211122/86 11:1!1121 iZll/22/86 17:00 !211 /22/86 23:1210 1211/23/86 1215: !'ZHZI V.ll /23/86 11: 1!10 1.!11/23/86 17: 1!10 01/23/86 23:1210 !211/24/86 05: 0121 li.i1 /24/86 11:00 !211/24/86 17:00 lZil/24/86 23: tZI0 01/25/86 05: 1!1121 1!11/25/86 11:1210 !211 I 25/86 1 7 : 121121 01/25/86 23:1210 l!il /26/86 1215: V.h!l 1211/26/86 11:0fll ~211/26/86 17:Y.I0 !211/26/86 23:1210 1!1 1 /27 I 86 !215: !ZH!I !.ill /27/86 11: Qll21 01/27/86 17: 1!!121 !211 /27/86 23: 1210 BYTE 183 185 187 189 191 193 195 197 RAW DATA --------------------18 1!214 18 H14 18 104 19 Hl4 MV 3.6 3.6 DEPTH INCHES ------------ 7.2 7.2 3.6 7.2 3.8 7.6 DAILY AVERAGE VALUES 19 105 19 105 18 105 18 11Zl4 DAILY 3.8 7.6 3.8 7.6 3.6 7.2 3.6 7.2 AVERAGE VALUES 199 18 105 3.6 7.2 201 18 105 3.6 7.2 203 17 105 3.4 6.8 205 16 105 3.2 6.4 207 209 211 213 215 217 219 221 223 225 227 229 231 233 235 237 239 241 243 245 DAILY AVERAGE VALUES 17 105 16 105 16 105 16 105 DAILY 15 105 15 105 15 104 14 11!14 DAILY 14 1 lll4 17 104 18 104 20 104 DAILY 24 104 27 1!!15 20 11215 16 1!!14 DAILY 12 11214 12 11214 3.4 6.8 3.2 6.4 3.2 6.4 3.2 6.4 AVERAGE VALUES 3.10 6.0 3.!21 6.121 3.0 6.0 2.8 5.6 AVERAGE VALUES 2.8 5.6 3.4 6.8 3.6 7.2 4.121 8.0 AVERAGE VALUES 4.8 9.6 5. 4 1!21. 8 4.121 8.121 3.2 6.4 AVERAGE VALUES 2.4 2.4 4.8 4.8 13 104 2.6 5.2 14 104 2.8 5.6 DAILY AVERAGE VALUES DATA FILE NFORK01 START: 12/28/85 11:00 STOP: 01/08/86 09:00 G1= 121 STAGE IN. ---------- 7. 21!1 7.20 7.20 7.60 7.30 7. 6!21 7. 6121 7. 2£!1 7. 2f!l 7.40 7.20 7. 2121 6.80 6. 4121 6.90 6. 8121 6.40 6.40 6. 4fll 6. 5£!1 6.1210 6 0 0121 6.00 5.60 5.90 5.60 6. 8121 7.20 8.1210 6.90 9. 61!1 11!1. 8!ZI 8. 1!10 6.40 8. 7121 4. 81c!l 4. 8121 5. 2!21 5. 6121 5. 1121 G2= 0 DISCHG CFS ====== 0 0 {!I 121 !!I 0 0 !!I 0 0 0 0 121 0 0 0 121 121 f.!! 0 TEMP DEG C ---------- 2. Ql 2. Ql 2 .Ill 2. V.l 2. 1!1 2.,5 2.5 2.5 2. Ql 2.4 2o5 2e5 2o5 2.5 2.5 2.5 2.5 2.5 2.3 2.0 2. !21 2. Ql 2.0 2. !Zl 2. Qi 2.5 2.5 2 • !!I 2.!li 2. !ZI 2. Q! 2. IZI 2.0 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 5 12-1!13-86 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*CDEPTH+G0)AG2 G0= £1 DATE TIME ----------------===== i!ll /28/86 1215:0121 1!11 /28/86 11: 121!21 Qli/28/86 17: i!l0 QH /28/86 23: Y.lfZ! !Zl1 I 29 I 86 05: ~210 ~!11 I 29 I 86 11 : Y.lf2l i!11/29/86 17:Y.Ik!l QS1 /29/86 23: 0'-!1 BYTE 247 249 251 253 255 257 259 261 RAW DATA -------------------- 13 11214 14 11214 14 104 MV 2.6 2.8 2.8 DEPTH INCHES ------------ 5.2 5.6 5.6 13 104 ~-6 5.2 DAILY AVERAGE VALUES 13 11214 13 1#ll4 13 1fll4 2.6 2.6 2.6 5.2 5.2 5.2 13 105 2.6 5.2 DAILY AVERAGE VALUES DATA FILE NFORK01 START: 12/28/85 11:00 STOP: 01/08/86 09:00 G1 = IZI STAGE IN. ===== 5.20 5. 6f21 5. 6Qi 5. 2Y.l 5. 4£!1 5.210 5. 2121 5. 21!1 5.20 5. 21!1 82= 0 DISCHG CFS ====== TEMP DEG C ---------- 2. l!i 2. Ql 2. !Zl 2.0 2. fll 2. 1'21 2. !!I 2.,5 2. 1 ~LA~KA ~UW~k AUIHOklfY l~MP/~IAG~ ~IUD1E~ DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER F'age 1 !212-!~9-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG~G1*CDEPTH+G01~G2 Gf2l:::: 1!.1 BEGIN OBS END OBS D{HE Tit1E ----------·------·----------- J!l1 / 3~1 /86 l 1 : !ZI!!l !!11/3!21/86 17:QH21 ~2!1. / 3!21 /86 23: 00 Qil /31/86 (15: Ql!ll lZll/31/86 11:1!1121 1?.11 / 31 /86 1 7 : 00 01/31/86 23: 0t1 Jll2/Qll /86 Ql5: 1210 (!12 I IZI 1 /86 11 : !ZIY.l 1212/l!ll/86 17: 121f2l 02h~l1 /86 23: l~H!l 1212/1!12/86 1!15: I!Hll !!12/1!12 I 86 11 : ~1£1 QI2/QI2/86 17: ~~1!1 1!12/02/86 23: !ZIQl 1212 /!!1:3 /86 !Z15: 0!21 1!12/1213/86 11: 01ll !.!12/03/86 17: 121!21 02n!13/B6 z~;: 00 1!12/!214/86 1!15: 00 !212/1!14/86 11:1i.ll!J f.:I2/QI4/86 17: f!l0 02/IZ14/86 23:0121 02/!215/86 1215: !!11!.1 Ql2/1Zl:'i/B6 11: !lil2l 1!12/!!15/86 17: !!lt!i Y.l2 I !215 /86 2:2.>: t-!10 END AT 11:~17 BYTE RAW DATA DEPTH MV INCHES ==== ========== ==== ====== 1 12 11!14 3 13 105 2.4 2.6 4.8 5.2 5 13 105 2.6 5.2 7 9 11 13 15 17 19 21 23 25 27 29 DAILY AVERAGE VALUES 13 105 13 105 2.6 2.6 5.2 5.2 12 105 2.4 4.8 12 105 2.4 4.8 DAILY AVERAGE VALUES 12 Hl5 l.2 104 12 lf2J5 12 11.!15 DAILY 13 105 13 1Ql5 13 Hl5 2.4 4.8 2.4 4.8 2.4 4.8 2.4 4.8 AVERAGE VALUES 2.6 2.6 2.6 5.2 5.2 5.2 12 105 2.4 4.8 DAILY AVERAGE VALUES 31 12 104 2.4 4.8 33 12 105 2.4 4.8 35 12 105 2.4 4.8 37 12 105 2.4 4.8 39 41 43 45 47 49 51 53 DAILY AVERAGE VALUES 12 104 11!14 104 2.4 2.2 ..., ,.., "'-• .L. 4.8 4.4 4.4 11 11 10 103 2.0 4.0 DAILY AVERAGE VALUES 9 1!!13 11 11!13 11 104 1.8 2,.2 2.2 3.6 4.4 4.4 10 104 2.0 4.0 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 Gl= 121 STAGE IN. ---------- 4.80 5. 2!!1 5. 2(? 5.07 5. 2C!i 5.20 4. 81!1 4.80 5. QS0 4. 81!1 4.80 4. 8121 4.80 4. 8121 5.20 5.210 5.20 4.81!1 5.10 4. 8!!1 4. 8Y.I 4. 8!!1 4. 8~!1 4.80 4.80 4.40 4. 4!ZI 4. QHZI 4. 4t~l 3. 6121 4. 4i!l 4. 4!!1 4. Y.l!ll 4. lQI 82= 0 DISCHG CFS ====== 0 ,21 12! 0 0 0 121 0 Ill !!I TEMP DEG C _ .. ____ . ----- 2.5 ,..., c:· ""'"-. ,_,t 2.5 ::.=-:. 5 ,.., r:: ..,;:.;. . _, 2.4 2.5 2.5 2.5 ~ ~· ..:.:. . .....; 2.5 2.4 2. !21 2. !!! 2.121 1.9 1.5 1. 5 2. 121 2. ~25 1.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER Page 2 1212-!219-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 DATE TIME -------------------------- !?.I2/QI6/86 ":15: I!JI?.I !:.'?2/106/86 11: !211!1 Ql2/f!l6/86 17; l!i!:':l Ql2/l!l6/86 23: Y.IQI !Zl2/i!l7/86 1!15: 0121 t!l2/07 /86 11: 00 1.!12/1!17 /86 17: QSJ!I l2l2/IZI7/86 23:01!1 02/08/86 w:J5:1ZI!o ~!l2/!ZI8/86 11: Y.S0 t:l2/t(l8/86 17: 121!21 1!12/1!18/86 23: IZl!!l ¥.12/!219/86 IZI5:1Zil!l 1!12/!ll9/86 11:00 l~i2/l2i9/86 17: flil!l (i!2/1Zl9/86 23: IZIJ!I 02/ 112!/86 Ql5: l!lt!l 1212/ 11!1/86 11: 0121 1!12/10/86 17:00 02/ h!l I 86 23: IZIIZl 1!12/ 11/86 !215; Qf!ZI 1!12/ 11/86 11: Y.Jf?l l!i2/ 11/86 17: l!ll!l !212/ 11/86 23: f:!IY.I 1!.12 / 1 2/86 Ql5: flll!l 1!12/12/86 11: !21!!1 ~~2/ 12/86 17: !Z10 !2!2/ 12/86 23: Y..lf!l 1!12/1:3/86 l!i5:1!1!ZI 11.12/ 1 :.::; / 86 11 : lZI!!l !::12/13/86 17: l!lY.l ii.l2/ 13/86 23: ~.''iQI BYTE 55 57 59 61 63 65 67 69 RAW DATA --------------------11 104 MV DEPTH INCHES ------------ 4.4 14 105 2.8 5.6 20 104 4.0 8.0 28 105 5.6 11.2 DAILY AVERAGE VALUES 34 11!15 35 105 32 105 3!21 106 DAILY 6.8 13.6 7.121 14.0 6.4 12.8 6.12! 12.0 AVERAGE VALUES 71 28 106 5.6 11.2 73 31 106 6.2 12.4 75 35 106 7.0 14.0 77 33 106 6.6 13.2 79 81 8 '"'!' ·-· 85 87 89 91 93 95 97 99 1!21 1 H13 11!15 107 11!19 111 113 115 117 DAILY AVERAGE VALUES 30 1~16 29 106 26 U!l6 27 Uil6 DAILY 27 107 28 11217 29 107 29 106 DAILY 27 106 26 l!ZI6 6.0 12.!21 5.8 11.6 5.2 1~1.4 5.4 10.8 AVERAGE VALUES 5. 4 liZ!. 8 5.6 11 ... 2 5.8 11.6 5.8 11.6 AVERAGE VALUES 5.4 5.2 ll!l. 8 11!1.4 26 106 5.2 10.4 25 106 5.0 10.0 DAILY AVERAGE VALUES 24 105 4.8 9.6 23 105 4.6 9.2 22 105 4.4 8.8 22 105 4.4 8.8 DAILY AVERAGE VALUES 21 1Y.f5 21 1~15 4.2 4 ··.• ...... 8.4 8.4 20 105 4.0 8.0 20 105 4.0 8.0 DAILY AVERAGE VALUES DATA FILE NFOR~~2 START: 01/30/86 11:00 STOP: 04/23/85 11:00 81= !Zl STAGE IN. ===== 4. 4121 5. 61!1 8. 0Ql 11 • 2121 7. 3V.l 13. 61!1 14. 0121 12.80 12. 0t!i 13. lfZI 11. 2!!1 12. 41!1 14. ~!!0 13. 21~ 12. 7t!l 12. !210 11. 6V.l 1!21. 4121 10.80 11 • 2121 10. 8!!.1 11 • 21!1 11. 6QI 11 • 6121 11 • 31Zl Hl. 80 10. 41!1 1!21. 40 10. ~~121 lf!1. 4121 9.60 9. 2121 8. Slil 8. 8!21 9. Hl e. 41!1 s. 41v 8. !210 8. IZIIZi 8. 21!1 82= !Zl DISCHG CFS ------------ !Zi !!I Ql 0 Ql TEMF' DEG C ===== 2. Ill 2.5 2. Ql 2.5 2.5 2.5 2.5 3. ~~j 2.6 ~!. • IZI 3. !21 3. l!l 3.0 3.0 3. 1!1 3. e1 3. 121 3.5 ...,. r:::: ..;.. . ....; 3. f?l ::.4 3. l!l 3. 121 3. ~!~ 3. V.l 3. !21 2.5 ::.5 ,., <::' ""' . .._, <"'*\ c::::· "'-·.....J ,.., c:· ..::...J ...... I:" .;:;. ..... } ALASKA POWER AUTHORITY TEMP/SlAGE SfUUlES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER F"age ::; !212-1219-8: BRADLEY LAKE HYDRO PROJECT NORTH FORk OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 Gl!l= fi.l DATE TIME -...-----·-------------------- Q)2/ 14/86 ~i5; t!.H~i 1!12/ 1'~/86 11: l!l!~l ~~12/14/86 17:0111 i!l2/ 14 I 86 23: 0!ZI !!12/ 15/86 1!15: !21!!1 1212/15/86 11:1211!1 !!12/15/86 17: IMI ~.!12/ 1.5/86 23: I!H!I k!2/ 16/86 05: 0!ZI !212/16/86 11: ~1il!l 02/16/86 17:~!10 !!12/16/86 23: IZI£1 1!12/ 1 "7/86 05: 1!1~1 1212/17/86 11:!!11!1 !92/ 17/86 17: 0!!1 02/17/86 23: 0!!1 1212/18/86 ~~15:!111Zl 1!12/ 18/86 11: 1Z1e1 !:!12/18/86 17:1!1121 02/18/86 23:!!JrZI !212/19/86 1215; Y.l0 k:12/19/86 11:0fll 1!12/ 19/86 17: 0!!1 Y.l2/ 19/86 23: 0f(J iZJ2/20/86 1!15: 0!!1 1'.!2 /21!1 /86 11 :12HZ! J!l2/2(1/86 17: IZI!Z\ ~.:l2/21!U86 23: !!II? 1!12/21/86 ll15: 0!21 1212/21/86 11: !2)1!.1 02/21/86 17: 121!21 QI2/21/B6 23:0121 BYTE RAW DATA MV DEPTH INCHES ==== ========== ====== 119 19 104 3.8 7.6 121 18 104 3.6 7.2 123 19 104 3.8 7.6 125 18 104 3.6 7.2 127 129 131 133 137 139 141 143 145 147 149 151 153 155 157 159 161 163 165 167 169 j, 71 173 175 177 179 181 DAILY AVERAGE VALUES 17 11!14 16 U!l4 18 H14 1.6 104 DAILY 3.4 3.2 3.6 6.8 6.4 7.2 3.2 6.4 AVERAGE VALUES 14 104 2.8 5.6 15 104 3.0 6.0 17 104 3.4 6.8 16 104 3.2 6.4 DAILY AVERAGE VALUES 14 104 13 104 2.8 2.6 5.6 5.2 15 104 3.0 6.0 14 104 2.8 5.6 DAILY AVERAGE VALUES 13 11214 15 11!14 16 104 15 104 DAILY 16 11214 19 11214 26 104 28 19.14 DAILY 28 HZI4 31 11!14 32 1 !214 21 11214 DAILY 19 104 18 Hl4 19 1!!14 15 Hl4 DAILY 2.6 3. !Zl 5.2 6r0 6.4 3.!21 6.121 AVERAGE VALUES 3.2 6.4 3.8 7.6 5.2 1{!1.4 5.6 11.2 AVERAGE VALUES 11.2 6.2 12.4 6.4 12.8 4.2 8.4 AVERAGE VALUES 3.8 7.6 3.6 7.2 3.8 7.6 3.1!1 6.0 AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 G1= ~!I STAGE IN. ----------- 7. 6!EI 7. 21!1 7. 6Y.I 7. 21!1 7. 41!1 6. 8!21 6. 4Y.I 7. 2!21 6.40 6. 71!1 5. 6~!1 6.1!10 6. 81!1 6. 4!21 6. 2121 5.60 5. 2§21 6. 1!1121 5.60 5. 6121 5.20 6. 1.!1!21 6.40 6. 1!11!1 5. 9121 6.40 7.60 1 QJ. 4~1 1. 1. 20 8. 9121 11.2121 12. 4121 12. 81!1 8. 41!1 11 • 2!21 7. 61!1 7. 2121 7. 6!!1 6. QHZI 7. HI G2= ~21 DISCHG CFS ..... _. ____ _ ·------ Y.l !(I 0 121 0 Qi V.l 0 !21 0 0 0 0 121 0 Ql fEI"IF' DEG C _..., ___ _ ----- 2. Ql 2. 121 2. !?i 2. Q! 2. r!> 2.0 2. !21 2. ~2\ 2. Ill 2. ,z; 2.0 2. 1!1 2. '!') 2.1!1 2. Y.l 2.1!l 2. f!l 2.1!1 2. ~2i 2.121 2. a1 2. !!1 2.1!1 2. 121 2. !21 2. '~l 2. 121 2.0 2. lll 2. Ql 2. 121 2. l!l 2. l!i 2. Qi 2. QJ ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER F'age 4 102-!!!9-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*(DEPTH+G0>~G2 DATE TII"IE ======== ===== 1!12/22/86 05:12l!ZI J!l2/22/86 11: 1211.!1 1!12/22/86 1.'7:1~fZI !.!12/22/86 23: 1!10 iZ12/23/86 IZ15: 00 lll2/23/86 11:1210 i2l2/23/86 17: !Zifll 1212/2:3/86 23: 01:':? ~2i2/24/86 ~~15: 1210 IZI2/24/86 11: Qif!l 02/24/86 17:00 !!12/24/86 23: 1!1!!1 !212/25/86 !215: 00 ~!12/25/86 1.1:010 !!12/25/86 17: 0!21 W.i2/25/86 23:00 L~l2/26/86 1215: IZ5el 1212/26/86 11: l..i!IZI ~!12/26/86 17: Q!Ql QS2/26/86 23: 1210 !i:l2/27 /86 !2l5: 0Y.l J!12/27 /86 11: 00 (12/27/86 17:12@ 1212/27/86 23: Y.l0 ~~12/28/86 !215: 00 1!.12/28/86 11:l21QI 02/28/86 17: 0!21 !212/28/86 23:010 !!I~; I !21 1 / 86 1!15: 1.!1!21 121~5/~) 1/86 11: !0(8 !!53/1!11/86 17:Y.H!I 121:::/(11 /86 23:1210 BYTE RAW DATA MV DEPTH INCHES ==== ========== ==== ------------ 1.83 185 187 189 191 193 195 197 199 21Zil 2!21~3 2!215 21217 209 211 213 215 217 219 221 223 225 227 229 13 11114 11 104 12 11?.14 11 11!l4 DAILY 11 103 16 103 2.6 5.2 2.2 4.4 2.4 4.8 2.2 4.4 AVERAGE VALUES ,.., ,.., .......... 3.2 4.4 6.4 20 104 4.0 8.0 14 104 2.8 5.6 DAILY AVERAGE VALUES 11 !f213 11!1 1 f£)4 11 104 '"'II , .. , ..c. • .:.. 2. l!i 2.2 4.4 4.0 4.4 10 104 2.0 4.0 DAILY AVERAGE VALUES 12 1Sl14 12 104 13 H!i4 11 104 DAILY 10 104 10 Hl4 9 1 Y.l3 9 llll3 DAILY 8 11!12 a 102 9 11212 9 102 DAILY 2.4 4.8 2.4 4.8 2.6 5.2 2.2 4.4 AVERAGE VALUES 2.0 4.0 2.f21 4.0 1. 8 3. 6 1. 8 3. 6 AVERAGE VALUES 1. 6 3. 2 1. 6 3. 2 1. 8 3. 6 1. 8 3. 6 AVERAGE VALUES 231 7 102 1.4 2.8 233 8 103 1.6 3.2 235 7 103 1.4 2.8 237 11 103 2.2 4.4 DAILY AVERAGE VALUES 239 32 102 6.4 12.8 241 41 101 8.2 16.4 243 44 101 8.8 17.6 245 44 102 8.8 17.6 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01./30/86 11:00 STOP: 04/23/85 11:00 Gl = Ill STAGE IN. ===== 5. 21'21 4. 4QI 4. 8QI 4. 41Zl 4. 7!ZI 4.40 6.40 8. QHZI 5. 6V.I 6.10 4.40 4. 0!!1 4. 4~!1 4. V.10 4. 21!1 4.80 4. 81!1 5. 2!21 4.40 4.80 4.00 4. 0QI 3. 6!ZI 3. 6!!1 3.80 3.20 3.20 3.60 3.60 3.40 2.80 3.20 2. 8!2> 4. 4!21 12. 8(!1 16. 4!21 1 7. 61!1 17. 6~>!1 16. Hi 62= i!l DISCHG CFS ====== 10 Ql 1?1 0 Ill Y-1 V.l 0 0 0 TEMP DEG C ------· ----- 2. !21 2. (!} 2. 121 2. Qj 2.0 1.5 1.5 2.0 2. Y.l 1..8 1.5 2. f.l 2. Ql 2. 121 1.9 2. r!i 2. 121 2.0 2. !21 2. C!i 2.0 2. V.i 1.5 1.5 1. 8 1. IZI 1. !21 1.0 1.0 1. (!I 1.1'21 1.5 1.5 1.5 1.4 1. QJ QJ. 5 Ql. 5 HLA~KA ~UW~k HUIHUkliY I~M~/tiiHb~ ~IUUl~~ DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER !-'age 5 !212-09-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 G0= ~~~ 0{-iTE TIME ======== ===== Y.13/!!l2/86 05: Y.l!21 1213/!!12/86 11: 0rll kl3/02186 17: IZIQI i2!3/l212/86 23: IZIQI 03/1213/86 IZI5: IZI!ll ~!131t:l3186 11: !210 IZI3/IZI3186 17: 00 1213/03/86 2:.:.\: !Zlkl ~!1:3'./ fll4 I 86 1215: QlQI 031QI4/86 11: !lli!l 1213/04186 17:00 03/1!14/86 23: 1210 IZI311ZI5186 1!15: (iiJll IZI31'1215/86 11 : 00 0311!15186 17: 1210 0:\/05/86 23:00 1213/ !!16 I 86 IZ15: IZI0 !.0311216/86 11: IZHZI ~331!216/86 17: 0!!1 IZ13/ ~:!16/86 23: V.i!ll l!l::::\/s£17/86 !Zl5: 0Ql 1(.13/Ql7 186 11.: 1210 03/!!17186 17:1!1(21 !213/07 /86 23: ~!1!!1 1!13/1!18/86 05:00 t!t3/IZ!8 I 86 11 : 1211!1 !!13/08/86 17: 0~!1 !?.1:5/08/ 86 23: 1!11!1 1!13/ 1!19 /86 !215: !ZS!ZI fZI3/Q!9 /86 11: !!1!2i l-!13/lil9 /86 17: 121(!1 03/1!19/86 23: !ZI!Zl BYTE 247 249 251 253 '?~C" ~;;:J.:.J 257 259 261 263 265 267 269 271 273 275 277 279 281 283 285 RAW DATA MV DEPTH INCHES ========== ------------ 40 101 37 11!11 37 HH 39 11!12 DAILY 42 1 fZl2 45 102 46 1 Y.l2 4121 103 DAILY 31 11ZI2 25 11212 22 102 21 11!13 DAILY 21 1Y.I2 24 101 8.1!1 1.6.!!1 7.4 14.8 7.4 14.8 7.8 15.6 AVERAGE VALUES 8.4 16.8 9.121 18.121 9.2 18.4 8.~1 16.0 AVERAGE VALUES 6.2 12.4 5. 0 1121. ~~ 4.4 8.8 4.2 8.4 AVERAGE VALUES 4.2 4.8 8.4 9.6 30 101 6.0 12.0 34 102 6.8 13.6 DAILY AVERAGE VALUES 39 102 7.8 15.6 44 102 8.8 17.6 48 102 9.6 19.2 51 103 10.2 20.4 DAILY AVERAGE VALUES 287 53 103 10.6 21.2 289 57 102 11.4 22.8 291 61 102 12.2 24.4 293 64 103 12.8 25.6 DAILY AVERAGE VALUES 295 66 102 13.2 26.4 297 67 102 13.4 26.8 299 70 102 14.0 28.0 301 70 102 14.0 28.0 303 305 3!!17 31!19 DAILY AVERAGE VALUES 66 11!12 65 1!212 62 1!213 6121 1 1!15 DAILY 13.2 26.4 13.0 26. Qi 12.4 24.8 12.0 24.!21 (-WERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 G1= 1!1 STAGE IN. ---------- 16. 01!1 14. 81!1 14.8121 15. 6!!1 15. 3kt 16. 81!1 18. 1210 18. 4~1 16.00 17. 3Y.I 12.4121 1 !ZI. 00 8.80 e. 4121 9. 9lll B. 4121 9. 6121 12. ~10 13.60 Hl. 9121 15.60 17. 6fZ> 19.20 20. 4121 18. 2Y.i 21. 2121 22. 8121 24. 4121 25.60 23. 51il 26. 4121 26. 812! 28. 1!1121 28. JZ10 27. 3Jll 26. 4121 26. Ql(!l 24. 81!1 24. !lHZl 25. 3!21 G2= i!l DISCHG CFS ------------ Ill !21 0 0 0 0 V.l 0 !21 121 0 0 0 121 fll TEMP DEG C ---------- 1. J21 Ql. 6 1. lZJ 1. ~~ 1. Qi 1 e 5 1.1 1 • !!I 1. V.l 1.0 1.5 1.1 1. Ill !!i. 5 ~~-5 1.0 !ZI. 8 1. (-l 1. 121 1. ~!! 1.5 1.1 1.5 1.0 LIZ! 1.5 1. 3 1.121 1. Ill 1. Ql 1. !!I 1. i:!l 1. 5 ,.., c:::-.... u 1.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 6 1212-!219-8/ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*CDEPTH+G0)AG2 DATE TII'1E -------------------------- ~!13/ Hj/86 f2j5: Q!0 1-:1::;: I Hl /8 6 1 1 : 121!!1 V.l3/HI/86 17:!!10 !Zl3/ 1121/86 23: 01!1 '.!13/ 11/86 !Zl5: 0121 !213/ 11/86 11: 01!1 1!13/ 11/86 17:0121 1!13/11 /86 23: 0121 ~il:3/ 12/86 1215: 1!1121 ~213/12/86 11:r210 £!13/12/86 17:01!1 1213/12/86 23:0121 12}:::;/ 13/86 1215:00 !213/13/86 11:1210 fl13/ 13/86 17: 0121 J.:!l:)/ 1.3/86 23: 00 llS:J/ 14 I 86 05: 01.ii Ql3/ 14/86 11:1210 1213/14/86 17:1!10 !ZL::; 14/86 23:1:210 1EI:J. / 1 5/86 !215 : fl}0 Y.l3/ 15/86 11; 00 03/15/86 17:1210 i'lS3/15/ 86 23: 01l! Y-13/ 16/8,~ 1!15: 01!1 03/16/86 11: 0f!l J.!l::~/16/86 17:Ql0 J.!i3/16/86 2:3: @!I !ZI:::::/17/86 ~~15:1210 ~!1~.:'::/ 17/86 11: IZI!!I m:::;:; 17/86 17:1210 Qr::;:; 17/86 23: 1210 BYTE 311 313 315 317 319 321 323 325 327 329 331 333 335 337 339 341 343 345 347 349 351 353 355 357 359 361 363 365 367 369 371 373 RAW DATA M'V DEPTH INCHES ========== ==== ====== 56 1~!!5 55 1!!15 53 U!l5 52 112!5 DAILY 52 11!15 50 105 42 11!l5 7 11215 DAILY 4 105 4 11215 4 11!}5 5 106 D~HLY 5 1!216 4 106 4 106 5 106 DAILY 4 1£15 4 11215 4· 11216 4 1fll6 DAILY 4 1 fZl6 4 106 4 105 4 Hl6 DAILY 4 1 !216 4 1 V.15 11.2 22.4 11. 0 22. !21 10.6 21.2 1!!1.4 21!1,8 {-WERAGE VALUES l!Zl. 4 2121.8 10. 121 20. !21 8.4 16.8 1.4 2.8 AVERAGE VALUES 0. 8 1. 6 121. 8 1. 6 121.8 1.6 1. 121 2. 121 AVERAGE VALUES 1. .121 2. fll Ill. 8 1. 6 121.8 1. 6 1. 0 2. 0 AVERAGE VALUES 0. 8 1. 6 !'21.8 1 .. 6 121.8 1.6 0.8 1.6 AVERAGE VALUES 0. 8 1. 6 0.8 1.6 0. 8 1. 6 0. 8 1. 6 AVERAGE VALUES 0.8 121. 8 1.6 1.6 3 105 0.6 1.2 4 105 0.8 1.6 DAILY AVERAGE VALUES 4 11215 3 11215 Ql. 8 0.6 1.6 1.2 3 105 0.6 1.2 3 105 0.6 1.2 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 81= 1!1 STAGE IN. ===== 22. 4121 22. 1!1!!1 21. 2121 2121. 80 21. 61!1 20. 8121 20.1210 16. 8121 2. 8!21 15. HI 1. 6121 1 • 61!1 1. 60 2. tZll!l 1. 70 2. 0121 1. 6121 1.60 2.00 1.80 1. 6121 1.60 1.60 1 • 6121 1.60 1.60 1.60 1. 6!21 1. 6Y.I 1. 6121 1. 60 1. 60 1. 2121 1 • 61!1 1. 50 1 • 61ZI 1. 21.!1 1 • 21ZI 1 • 21?1 1 • 31!1 G2= !!I DISCHG CFS ======= TEMP DEG C ---------- 2 .. 5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2 .. 5 2.5 ,...., c;: "'-. ,..J 3.Ql 3. 121 ~;. Ql 3. 121 :_::,. Qj 3. 1~1 2.5 2.5 3. Qj 3.0 2.8 3. Qj 3. QS "" c::' ..:.:. . ._, 3. f/.1 2.6 2.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 7 1!12-1!19-8~ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*<DEPTH+G0)AG2 GQI= Y.l 0?'-ITE TIME ----------------===== 03/18/86 1:!15: IZlQI Ql:::;;/18/86 11:1!1121 ~:~~.::;; 18/86 17:1210 1213/18/86 23: !210 l!l3/1 9/86 !215: 0!21 12!3/19/86 11:00 Ql3/ 19/86 17:1210 l!l3i 19/86 z~;: 0121 ~!1::::;2121/86 05: 1!1!21 !2!3/2!Zi/86 11: 1!1!21 k'i:3/20/86 17:00 !Zl3/21ZI/86 23: !ll!Zl Ql3/21 /86 1215: !!liZ! !ZI3/21/86 11: 00 m3/21/86 17:00 !213/21/86 23:00 1213/22/86 rZS5: li.lt!l 1213/22/86 11: Y.HZI ~~~~$/22/86 17: !210 1!!3/22/86 23: IZll!i 03/23/86 05: !Zlf!l kl3/23/86 11:00 1213/23/86 17: 1210 !1.13/23/86 23: 0Y.l I!J::.\/24/86 1215: ~!1121 ii13/24/86 11: V.H!I Ql3/24/86 1.7:0~!1 !?.13/24/86 23: ~!1121 \Zl3/25/86 !215: (!lf!l !213/25/86 11: 11.1!3 !!1~:./ 25 I 86 1 7: 121121 QJ::~/25/86 23:00 BYTE ==== 37!'5 377 379 381 RAW DATA ========== 3 1.05 3 11!15 3 11216 MV ==== 0.6 Ql. 6 0.6 DEPTH INCHES ------------ 1.2 1.2 1. 2 3 105 0.6 1.2 DAILY AVERAGE VALUES 383 3 105 0.6 1.2 385 3 105 0.6 1.2 387 3 105 0.6 1.2 389 3 105 0.6 1.2 DAILY AVERAGE VALUES 391 2 105 0.4 0.8 393 2 104 0.4 0.8 395 3 104 0.6 1.2 397 3 105 0.6 1.2 399 4f~1 403 405 407 41219 411 413 415 417 419 421 DAILY AVERAGE VALUES 3 11215 3 104 121. 6 0.6 1.2 1. 2 3 105 0.6 1.2 3 105 0.6 1.2 DAILY AVERAGE VALUES 3 11215 2 1 1!14 2 11214 0.6 121.4 0.4 1.2 f!l. 8 0.8 3 105 0.6 1.2 DAILY AVERAGE VALUES 2 105 0.4 0.8 1 104 0.2 0.4 3 104 0.6 1.2 3 105 0.6 1.2 DAILY AVERAGE VALUES 423 3 1V.l5 425 3 11215 427 2 106 0.6 121. 6 0.4 1 . ., ...... 1. 2 0.8 429 3 106 0.6 1.2 431 43~~ 435 437 DAILY AVERAGE VALUES 3 105 3 Hl5 IZI.6 0.6 1. 2 1. 2 2 105 0.4 0.8 3 105 0.6 1.2 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 Gl= 0 STAGE IN. ---------- 1 • 212i 1 • 212! 1 • 2f!l 1 • 21!1 1.20 1.20 1. 20 1. 20 1. 20 1 • 2121 Ill. 81!1 !!'. 8121 1 • 2!!1 1 • 21Zl 1.00 1. 20 1 • 2121 1. 20 1. 2121 1. 21Zl 1.20 0. 812S lZI. 8f!l 1 • 2121 1. Y.l0 so. 81!1 0.40 1 • 2121 1. 2121 !Zl. 9121 1 • 2Y.I 1. 20 121. 8~!1 1 • 2121 1. HI 1 • 2121 1. 2!!1 0. 81o 1 • 21!1 1. HI G2= !?J DISCHG CFS ------------- !!I 0 121 !21 121 l!i Ql TEI'1P DEG C ===== 2.5 2.5 3.lc? 2,5 2.6 2.5 2.5 1"') \:' ..::....w 2.5 2.0 2.5 2.4 2.5 2.121 2. Ql 2.5 2.3 2.5 2.5 2.5 2.5 3. Q) 3. IZI 2.8 2.5 2.5 2.5 '"' "" ...:..w~ 2.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 8 Ql2-QI9-8" BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*(DEPTH+G0)AG2 DATE TIME ======== ---------- !.?~.::;/26/86 1.:15: 1!10 1!13/26/86 11: 12HZ! 12.1~5/26/86 17:00 ~3~3/26/86 23: Y.l~~~ 1213/27/86 1Zl5: 0!2! 12.!3/27/86 11:00 1.!13/27 /86 17: t2l0 !!13/27 /86 23: IZ1121 1213/28/86 Ql5: 00 1!13/28/86 11: 1!!0 17.13/28/86 17: 1!1121 03/28/86 23: !!10 03/29/86 1!15: QIQI 1213/29/86 11: f!H!I 1213/29 I 96 17: 1!1!21 Q/3/29 /86 23: 01!1 1113/30/86 f215! 00 !!13/31Zl/86 11: Y.IIZI ~f3/3k?/86 17:0121 1!13/31!1/86 23:0121 !213/31/Bb 1215: 0!21 0~5/::51/86 11:00 1213131186 17: 01ll 03/31/86 23: Y.IQI 04/llll/86 05:0121 Q14IJ.!Il/86 11: 1!10 1214/ !211 /86 17: 01Zl 1214 I !Zil/86 23: 1!11!1 1!14 I 1!12 I 86 1215: IZII!I ~14/!212/86 11: !21121 IZilf /1212 / 86 1 7: l!SI21 Ql4/1212/86 23: 1!10 BYTE 439 441 443 445 447 449 451 453 455 457 459 461 463 465 467 469 471 473 475 477 479 481 483 485 487 489 491 493 495 497 499 5Y.l1 RAW DATA MV DEPTH INCHES ========== ==== ====== 2 11215 2 105 2 1 !215 2 105 DAILY 1 105 0 1 !Z14 4 104 2 104 DAILY 2 104 2 104 2. 104 2 104 DAILY 1 1 ,!14 0 103 1 Hl3 121.4 !2!.8 ~1.4 121.8 121.4 0.8 1!1.4 1!1.8 AVERAGE VALUES 121.2 1!1.4 0.0 0.0 !21.8 1.6 0.4 0.8 AVERAGE VALUES ,:1.4 0.8 121.4 0.8 121.4 (!1.8 121.4 1!1.8 AVERAGE VALUES 121.2 0. Ql V.l. 2 0.4 0.0 V.I. 4 1 103 0.2 0.4 DAILY AVERAGE VALUES 0 103 Ql 102 2 11213 2 1LiS3 DAILY !ZI 11212 10 103 22 1V.l4 23 104 DAILY 24 104 28 11!14 32 104 35 112J5 DAILY 36 1!!15 28 105 2 11!15 1 105 DAILY (4.0 t!I.QI 121.121 121.0 0.4 0.8 121.4 1!1.8 AVERAGE VALUES 0.121 ~21.0 2.0 4.0 4.4 8.8 4.6 9.2 AVERAGE VALUES 4.8 9.6 5.6 11.2 6.4 12.8 7.121 14.1!1 AVERAGE VALUES 7.2 14.4 5. 6 1 L 2 121.4 121.8 0.2 0.4 AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 Gl= ~!I STAGE IN. ===== 0. 8!21 1!>. 81!i !!1. 8121 Y.l. 8121 0. 81!1 1!1. 4121 .1!1.00 1 • 6121 !ZI, 8!21 0. 7121 0.80 0. 81!1 Ql. 8121 1!1. 81!> !21. 80 1!1. 41!1 0. 01!1 0. 4121 Ql. 40 121, 3121 1!1. 1211.!1 0. 1!10 0.80 1!1. 80 0. 41ll Ill. rlll21 4. l2112i 8.80 9. 2lll 5. 51!1 9. 6121 11 . 21!1 12. 8121 14. i!10 11.90 14.40 11. 2!!i li.l. 8!21 Ql. 4!21 6. 7!ll 82= 121 DISCHG CFS ====== Ql Y.J Qj fll 0 Ql Ql I! I Ill 0 TEI"IF' DEG C ----------- 2.5 2.5 2.5 2.5 2.5 2.5 2. !ZI 2.0 2. 12! 2. 1 2.0 2. !21 2. !21 2. Q! 2. i?l 1.5 1.5 1. 5 1.6 1.5 1. l!i 1.5 1.4 1. {!i 1.5 2.0 2. lli 1.6 2. Qi 2. j{l 2. ~2} 2. 1 2 .. 5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 9 12J2-m9-B7 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 GQI= !!I DATE TIME ======== ---------- Ql4/s~l3/B6 ~c:)5: ,ol'il !!14/!!13/86 11: J!lt!l ~.~14/1!13/86 17: 012l i2l4/J?.l3/86 23: 0t!l Y.i4/ !!14 I 86 05: 12'10 (ii41t!l4/86 11:00 1:?4/1!14/86 17: V.ll!l Q)4/1!14/86 23:00 12l4/!ZS5/8~ 05:00 1!:14 I Ql5/ 86 11 : 0f!l Qi4/Ql5/86 17: f!l0 !!14/!!15/86 23: Y.l0 ~1411!16186 05: tll!ll ~~i41QI6186 11:00 V.l4/QI6/86 17: 0121 lll4 / J!l6 I 86 23: 00 l?l41QI.7/86 1215: 00 1!14 I 1217 I 86 11 : Y.l0 Y.l ... ''t!(il7 /86 17: 0Y.I 121411!17 186 23: 1!10 1214/1!18/86 1215: 0J.:I 04/1!18/86 11:00 IZI4/Ql8/86 17: 0121 Ql4/Ql8/86 23: 0121 04/l!l<'Y/86 1215:00 i~i4/t~9/86 1.1:0121 1214/l!l'-i /86 1 7: Ql(1 1!14 / !!19 / 86 273;: 0121 !!i4 I 1 Y.l /86 1ll5: IZI!Zl ~!i4/11!!/86 11:0Y.l 1!14/ Hl/86 17: ~!10 Qi4/ll!l/86 23: 1210 BYTE RAW DATA ==== ========== 1'1V DEPTH INCHES ------------ 503 1 105 0.2 0.4 505 1 105 0.2 0.4 507 1 105 0.2 0.4 509 2 106 0.4 0.8 511 513 515 517 519 521 523 525 527 529 531 533 535 537 539 541 543 545 547 549 DAILY AVERAGE VALUES 2 11!15 2 1fl15 2 1{215 1 11215 DAILY 1 105 1 106 1 106 1 106 DAILY 1 1!215 1 105 1 11215 1 1~15 DAILY Ql 104 Ill 1 1!13 0 1 !213 1 1 !!'14 DAILY 1 1!214 4 103 4 104 2 104 DAILY 121.4 1!1.8 12).4 0.8 f2l.4 1!1.8 0.2 0.4 AVERAGE VALUES 0.2 0.4 1!1.2 Y.l.4 121.2 1?1.4 121.2 1!!.4 AVERAGE VALUES 1!1.2 121.4 12>.2 0.4 0.2 0.4 l2l.2 0.4 AVERAGE VALUES Ql.li.i 0.0 121.0 C!S.Ql 0.0 0.121 121.2 0.4 AVERAGE VALUES 0.2 V.l.4 0.8 1.6 0. 8 1. 6 li.l.4 0.8 AVERAGE VALUES 551 0 103 0.0 0.0 553 0 102 0.0 0.0 555 1 104 0.2 0.4 557 1 105 0.2 0.4 559 561 563 565 DAILY AVERAGE VALUES 2 11215 4 llll5 2 1V.l6 !21 11217 DAILY 1Zl.4 0.8 121.8 1.6 1!1.4 l!i.8 1!1 • Ill 0 • !21 AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 STAGE IN. ---------- 0. 41!1 V.i. 4121 0. 41~1 !!I. 8!21 121. 51!1 m.e0 0.80 IZI. 8!21 0. 4121 0. 7Ql 0. 41!1 Y.l. 40 0. 4121 0. 4121 l!l. 41.!1 Ill. 40 Ill. 40 121.40 1!1. 40 121.40 0.00 Ill. 01!1 0. l!llll !!l. 41!1 121. 1121 0.40 1.60 1. 6121 ""· 8!Zl 1 • 1 Y.l !Zl • Y.H!S 111 , fZI!!I 121. 4Qi !21. 4!!1 1/.l. 2121 1!1. 81!1 1 • 6V.l !21. 81!1 121 • !!Sill Ill. Sf!! 82= Qj DISCHG CFS ------· ·------ TEf1P DEG C ===== 2.5 2.5 2.5 311 1!1 2.6 2.5 2.5 2.5 :::;; • !!I 3. C~l ~j. l!l 2.9 2.5 2.5 2.5 2. Y.l 1 • :.t 1 """ • .J 1.8 2. 121 1.5 2. 1!1 2. k.'? 1.9 1.8 -. c;:-..:.:. • ...J 2.5 3. ~~~ "":"" C' .... :-. ._) 2. '7' HLH~KH ~UW~K HUIHUKllY l~n~/~IHb~ ~IUUl~~ DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER r-·age 1!~) l!l2-!2i9-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1•<DEPTH+G0>AG2 DATE T It1E _ .. ______ _ ---------===== 1!14/11/86 Y.l5:0~i iZI4/ 11/86 11: WY.I l2i4/11/86 17:01Zi 1!14 I 11/86 2~:: !lll!l 1214/ 12/86 12!5: 0~!1 1214/12/86 11:1210 {214/12/86 17: Y.llll ~14/ 12/86 23:00 1!14/13/86 05:00 QJi.j./ 13/86 11 : 1!10 lll4/ 13/86 17: 01!1 04/1 3 /86 23: 1!10 1!14/14/86 {215: t210 1!!4/14/86 11:01!1 !214/14/86 17: Qi0 1214/14/86 23:0121 1214/1 5/ 86 1!15: 1!10 !!14/15/86 11: lil0 1214/15/86 17:1!11!1 1214/15/86 23:fiJ0 !214/ 16/86 !ll5: 1210 12i4/ H:d 86 11 : 1210 k14/16/86 17: l!ll!l V.l4/ 16/86 23: 0!!1 1214 I 1 7/86 1215: Ql~!l 1214/17/86 11:1!10 IG!14/ 17/86 17: f:!I!2J . 04/17/86 23; P.l!2i \Zi4/18/86 I215:V.ll!i ~!14/18/86 11:J!il~ 1!14/ 18/86 17: !lSI!! 1214/18/86 23: 121~!1 El'{TE 56-7 569 571 575 577 579 581 583 585 587 589 591 593 595 597 599 601 603 61215 607 6~19 611 613 61::.; 617 619 621 623 625 627 629 RAW DATA MV DEPTH INCHES ----------==== ---------------------- Qi 1 1217 l!l .1!217 1 106 2 1!!16 DAILY 3 11216 2 11216 2 106 4 11216 DAILY 4 H217 4 11216 3 1Y.i6 4 1 1!16 DAILY 4 11217 3 1£2i6 4 1{217 4 106 DAILY 5 107 4 11!17 4 11217 4 106 DAILY 4 107 4 1 Y.l6 4 107 6 106 DAILY 121 • Ill IZI • 0 1!1.121 121.!21 0.2 0.4 0.4 v.s.e AVERAGE VALUES Ql.6 1.2 0.4 0.8 lll.4 1!1.8 0. 8 1. 6 AVERAGE VALUES 0. 8 1. 6 121. 8 1. 6 0. 6 1. 2 0. 8 1. 6 AVERAGE VALUES 121.8 1.6 0.6 1.2 rzs.8 1.6 0. 8 1. 6 AVERAGE VALUES 1.121 2.QI 121.8 1._6 0. 8 1. 6 !ll.8 1.6 AVERAGE VALUES V.I. 8 1. 6 0. 8 1. 6 121.8 1.6 1. 2 2. 4 AVERAGE VALUES 5 106 1.0 2.0 5 106 1.0 2.0 6 106 1.2 2.4 11 106 2.2 4.4 DAILY AVERAGE VALUES 11 106 2.2 4.4 10 106 2.0 4.0 12 106 2.4 4.8 18 106 3.6 7.2 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 81= li.! STAGE IN. ------·---- Ql • 121!!1 12i • fll!::l 0. 4V.I 121. 8!!1 10. 31~1 1 • 2121 121.80 Ill. 81!1 1.60 1.10 1. 6121 1. 612! 1. 2t.~i 1 • 6121 1. 50 1. 6121 1. 2121 1 • 6121 1. 6Y.i 1 • 5121 2 .1.!1121 1. 60 1. 6125 1 • 6121 1 • 7121 1. 6{!1 1 • 61() 1 • 6121 2.40 1 • 81!1 2. 1!10 2. l~l!!l 2. 4Qi 4. 4121 2. 7!21 4. 410 4. l!l!!i 4. 8~1 7. 21!1 5. HI 82= QJ DISCHG CFS ====== 121 0 0 0 V.l TEMP DEG C ---------- --:•· C" . ..;. .. ._) 3. 12i 3 .. ki 3.3 3. 1!1 3. Y-l 3. !ZI 3.0 3. Qj 3. QJ 3. !!I 3. 1 3. J2l 3.0 3.3 3. Y.> :3.4 3. l!l ..,. = ._ ... ,_J 3. ~~~ 3. l!l 3 a j!} 3. f2j 36 Qj 3. l2i 3. 121 3. Y.l 3l! i!) 3. Ql ALASKA POWER AUTHORITY TEMP/STAGE SfUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER P.age 11 !!l2-!ZI9-8~ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 80= 0 DATE TIME -------------------------- 04/19/86 1!15:!!@ 1214/19/86 11:!ZH!I !~14/ 1. 9 /bt:.; J.. ,,;. !ZI4 I 1 7/ 8t:. ._ .• l)k• Ql£1·/~::l!i /86 11.: J.%1 I:H I 21!! 1 86 i > ~ illQl 04/2!!:/86 23: 0!-.:i !b·4/ :.~ 1/ ;;;;\;_, ~;~);~:, ~ i:~tl!..j ~2)4 / 2l / l>(":J I J u ~~~~£~· U·'+ / "'>;;. /86 17: V.liil ;>:,.· .. .::::J86 23: V.IQ! i2l4/24 I 86 05: I!II?J 1!14/24/86 11: 1!10 !!14124186 17: 1!>12! fl4/24·186 23: 01!1 1!.14/25/86 fil5: 0QI 1214/25/86 11: Y.H!i ~~14/25/86 17:@!! Ql4/25186 23: 12Hcl 1214 I 26 I 86 i215: V.I!Zi !!14 I 26/86 11 : ~!H!l 1214/26/86 17: 1!1121 Qi4/26/86 2::::;: !!10 BYTE 631 63:;..\ o::N 641 643 645 RAW DATA ========== 17 10o i ... ' .!. ~!JO :;;.;.;::;=:.:..:. . .:.. " ·-+ 4.8 DEPTH INCHES "-· ·--· . --· --·----- ·.;;.. 0 DAIL~ AVERAGE VALUE5 2:'5 1 i2>6 22 107 24 ll?i7 32 1!i>7 \._,>f-l l L Y 4.6 9.2 4.4 8.8 4.5 7.0 6.4 1....::.~ H\.'c::kHl:k ·vtciL<.JO:::.:, 6"'t·.;;! ..::.6 J.!:l~' bt.I.L ~:'} L!l} ~-~ ••. q. ~,. ~) b;:'•;:i 2:S 1 W6 . ...:.: t:;.~~·:..; '2:.-. l ~~J7 n .{~ 667 669 671 673 675 677 679 681 683 685 687 689 691 693 18 11!.16 17 1 Y.l6 20 Hii7 19 U218 DAILY 19 1f!J7 18 107 18 109 23 108 23 23 "")"':!" ·'-·-· DAILY 1!217 11!17 109 •• ll ··-.:;. ; '':' 3.6 7.2 3.4 6.8 4.!21 8.0 3.8 7.6 AVERAGE VALUES 3.8 7.6 3.6 7.2 3.6 7.2 4.6 7.2 AVERAGE VALUES 4.6 4.6 4.6 9.2 9.2 9.2 ~")C' .s....J 108 5.0 10.0 25 25 24 25 DAILY AVERAGE VALUES 107 5.0 10.0 107 5.0 10.0 108 4.8 9,6 108 5.0 10.0 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: !Zl4/23/85 11. i~r. G1= Y.l 9. 6l!l 7. 4(il 8. b~:; 9. 61ci ... ~:. 8k:l .i.. :2. 4ili 11 . L~!i ] !?; ,. i:J\(.. l j •. .i. >.':J b. q.~l 8. !!Jill e. 6£1 7. 2121 6.80 8. (ilQ! 7. 61?1 7.40 7.60 7. 2121 7.20 9. 21!.1 7. 8121 9. 21!1 9. 2~!S 9. 212) 11EI. kill!l 9. 4!2! 1 Ill • W.IJ!! 1.1!!. itll!l 9. 61!1 l!Zl • l~Y.I 9. 9121 62= !?.i !!I l: ,·:.• :::::.:::=:::::::: :.::. « Y.l :2 .• {.(.; :;~. (t •·:r .;:. ._ ... ·-· ::. .• J ._-•• :c.:.i -:: •: '-· ..... .: : ;.;: ... • .. .__. • .:: •• ''·i -.· ,:;' .,) n "'.f 3.5 3.5 3.4 3. l!l "'?" c. ... • .,..\ ....... ...t 3.5 3.5 4.5 4.0 3.9 3.5 3.5 4.5 4. !Zl "':'" c::" __ , • ...J 3.5 4. !!l 4. f!! 3.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 12 ~~12-1219-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*<DEPTH+G0>AG2 DATE T I1'1E ·---·------------------------- ~~14/27 /86 !Zl~'i: l(l!!l (!!4/27/86 11:01!1 S!llf/27/86 17:00 1214/27/86 Z5:l!l!2! 104/28/86 rZJ5: !lil!J ~~14/28/86 11: 01!! 1214/28/86 17: !!10 1!14/28/86 23:00 ~~14/29/86 (.15: 0fll 1214/29/86 11 : !Cl!!l !ll4/29/86 17:00 £!!4/29/86 23: 121!21 1!>4/3121 /86 05: QJQ! 1!14/3$21/86 11:00 04 I 3121/86 1 7: IlliZI 1214/~::.Qi/86 23:00 Ql5/!li1/86 1!15: 0121 1!15/lZH/86 11: !ll0 1!!5/1!11/ B6 1 7: flJ'!l !35/!lH /86 23: !2,10 l!l5/l!l2/86 l215: I!H!I V.l5/1Zl2/86 11: 0121 05/02/86 17:0121 05/£12/86 23: 00 Ql5/~,3/86 05: 1211!.1 V.15/f~l3/86 11:121121 !ZI5/Ql3/86 17: I:JQI {Zl~)/!213/86 23: Qll!i 1!15/t~\4/86 05: l!lt2l Ql5/Ql4/8,~ 11: Q10 !ll5/l!l4/86 17: !21!!> i!15/04/86 23: 1!1!2! BYTE 695 697 699 7Qll 7J!l3 705 7tll7 709 711 713 715 717 719 721 723 725 727 729 731 733 735 737 739 741 743 745 747 749 751 753 755 757 RAW DATA MV DEPTH INCHES ----------====== ---------- 24 107 23 1 1!17 23 11Q) '*. 8 4.6 4.6 9.6 9.2 9.2 28 109 5.6 11.2 DAILY AVERAGE VALUES 28 107 27 107 3§21 11!21 5.6 5.4 6.1!1 11.2 10.8 12. Ql 46 107 9.2 18.4 DAILY AVERAGE VALUES 45 11217 41 11217 46 11fll 61 11218 DAILY 57 11217 52 1!!18 53 111 64 109 DAILY 60 1(19 55 109 55 11(1 63 1Y.I9 DAILY 62 1Ql7 58 108 57 111 6J!I 109 DAILY 9.0 18.0 8.2 16.4 9.2 18.4 12.2 24.4 AVERAGE VALUES 11.4 22.8 Hi. 4 2121.8 lY.I. 6 21.2 12.8 25.6 AVERAGE VALUES 12. Y.i 24. 0 11. 0 22. Y.l 11.0 22.0 12.6 25.2 AVERAGE VALUES 12.4 24.8 11.6 23.2 11.4 22.8 12.121 24.0 AVERAGE VALUES 56 108 11.2 22.4 53 109 10.6 21.2 52 111 10.4 20.8 54 110 10.8 21.6 DAILY AVERAGE VALUES 53 109 51. Hl9 48 11 Ql 48 11!!i DAILY 1J!l.6 21.2 U!l. 2 2t!l • 4 9.6 19.2 9.6 19.2 AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 G1= 121 STAGE IN. ---------- 9. 6121 9. 2121 9. 2fZ! 11 . 21!1 9. 8121 11 • 21!1 10. 8!ll 12. 1!10 18.40 13. 1121 18. £!0 16.41!1 18.40 24. 41!! 19. 3J!l 22. Bt!l 2121. 80 21.20 25. 6f!i 22. 61!1 24. 01!1 22. !llf21 22.00 25.20 23.:50 24.80 23.20 22. BIZ! 24. llll!l 23.70 22.40 21 • 2!!1 2~':5. 81!1 21. 61!1 21. 51!1 21.20 2t{l. 4Y.I 19. 2!21 19. 2121 21!>. 1211!.1 G2= 0 DISCHG CFS ====== Ql Ql I! I 0 Ill TEt•IP DEG C ---------- "';t" C' . ...) . ,_) 5. !Zi 4.5 4. 1. 3.5 3.5 5. QS 3.5 3.9 -"" . .;: .. ~ 3.5 5.0 4. !!) 4.0 3.5 4. 121 5.5 4.5 4.4 4~5 4.5 5. !2i 4.5 4.6 3.,5 4.0 5.5 4.5 4.4 4.0 4.5 5. i!! 4.8 4.5 4.5 5. Q! 5. 1!1 4.8 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER F'age 13 QI2-QI9-8. BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER s·rAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 DATE TII'1E -------------------------- 1!15/1!15/86 1?.15! !ZH!! 1!15/1!15/86 11: !.!IJ!I ~!15/!!.15/86 17: Ql0 1!15/~!15/86 23: 1!10 05/~!16/86 1!!5: 1!11?1 !:~15/!216/86 11: 00 1!15/12161 86 1 7: 121121 V.15/Ql6186 23: !210 051fu7 186 v.1::;: tZH!' !!15/1!17/86 11: ~!HEI ~~l5/Y.)7 /86 17: (1QI t!l5/l~f7/86 2::~: !21!21 IZI~:iiQIB/86 QS5: @21 1:!15 / 1!18 /86 11 : !2h21 l!i5/1218i86 17: V.10 {!15 I IZ18 I 86 23: 1!10 1215/1259/86 05: 00 1215/1!19186 11: I{.!QS 1!!5/ Ql9 I 86 1 7: 121!21 1!15 /09 I 86 23: QIQI Ql5 I 1121/86 ill5: I!H!l llJ51H3/86 11:0!21 1215/ 1!!1186 17: !21!21 05/ Hl/86 23:00 Y.'l5/ 11/86 lll~i: 0Ql !!15/ 11/86 11: IZH!I Ql5/ 11/86 17: ~~11:'.1 1!15 / l 1 I 86 z:;;: I?!Qi 1!15 I 12 I 86 Ql5: 121121 1!1::;; 12/86 11: IZH!I 1!15/12/86 17:1!11!1 1:!15/12186 2~;: 01!1 BYTE RAW DATA MV DEPTH INCHES ==== ========== ------------ 759 761 76~5 765 767 769 771 77;.\ 775 777 :7 79 781 783 785 787 789 791 793 795 797 799 8!21 1 803 81215 47 108 44 1!i.l7 46 113 56 111 DAILY 55 108 53 108 9.4 18.8 8.8 17.6 9.2 18.4 11.2 22.4 AVERF-)GE VALUES 11. !21 11!!.6 22. !!I 21.2 53 112 10.6 21.2 59 110 11.8 23.6 DAILY AVERAGE VALUES 56 108 54 1roa 11.2 1125.8 22.4 21.6 54 112 10.8 21.6 65 111 13.0 26.0 DAILY AVERAGE VALUES 62 109 58 110 55 111 56 110 DAILY 54 109 51 1(.~9 49 111 48 110 DAILY 45 1109 44 109 ·43 110 42 110 DAILY 12.4 11.6 11. IZI 11.2 24.8 22.0 22.4 AVERAGE VALUES HI.B 21.6 HI. 2 20.4 9.8 19.6 9.6 19.2 AVERAGE VALUES 9.fll 18.121 8.8 17.6 8.6 17.2 8.4 16.8 AVERAGE VALUES 807 41 107 8.2 16.4 809 40 108 8.0 16.0 811 39 111 7.8 15.6 813 40 112 8.0 16.0 815 817 819 821 DAILY AVERAGE VALUES 38 1 U!l 36 109 37 114 45 114 DAILY 7.6 15.2 7.2 14.4 7.4 14.8 9.121 18.Q! AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 81= 121 STAGE IN. ---------- 18.8121 17.60 18. 4!!! 22. 41!1 19. 31!1 22. !21!21 21.20 21.20 23.60 22. !ZIQJ 22. 4~~~ 21. 6!21 21. 61!1 26. 0!21 22. 9QI 24. 80. 23.20 22. li:IV.l 22.40 23. 10 21.60 21Zl. 4!21 19.60 19. 2121 20. 2t!> 18. Ql0 17. 6121 17. 2V.l 16. 8121 17.40 16.4121 16. 1211!! 15.60 1 6. !Zll!l 16. !21121 15. 2Y.I 14. l.j.!{j 14. 81!1 18. IZI!ll 15.6121 82= 1!1 DISCHG CFS ------· ------ Qi 0 Ql 0 1!1 !ZI 121 121 0 0 TEMP DEG C ---------- 4. 121 6. ~:; 5.5 4.9 4.12i 4.0 6.rZl 5. Y.l 4.8 4. Ql 4. ~!.l 6. Ill 4.9 4.5 5. ~!l 5.5 4.5 4.5 5.5 4.9 4.5 4.5 5.1!l 5.0 4.8 4. !!) 6. Ql 4.8 5. !2i 4.5 7. 1{1 7. 12i 5.9 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES Page 14 DATA REPORT FOR DATAF'OD DF'211SG -STAGE AND TEMP. RECORDER 02-1219-87 DATA FILE NFORI<I212 BRADLEY LAI(E HYDRO PROJECT START: 121 1 I 3JZ! I 86 11: Ql0 NORTH FORI< OF BRADLEY RIVER STOP: 1214/23/85 11 : !!l(:i STAGE=DEPTH+G!iJ DlSCHG=G1*<DEPTH+G0)AG2 80= Ql G1= Q! G2= 0 DEPTH STAGE DISCHG TEMP DATE TII'1E BYTE RAW DATA MV INCHES IN. CFS DEG c -----------------========== ---------------------· ------·---------------------------------- J.:l5/ 13/86 05: l2ll2l 8''"'. ..<.;.~\ 46 11QI 9 ~.1 ..... 18.4 18. 4121 !21 5. l1l 1!15/13/86 1 1 : IZIY.l 825 44 H39 8.8 17.6 17. 6121 10 4.5 ~!!5/ 13/86 1 7: Q!Qi 8'">"7 ..:..' 44 113 8.8 17.6 17.60 0 6.5 l!i5/ 13/86 23: 1!112! 829 49 112 9.8 19.6 19. 61Zl I! I 6. tl DAILY AVERAGE VALUES 18. :;>!21 0 c.: "" ...;. -· l/.i5/ 14/86 ~15: !21121 831 50 11Y.! Hi.JZl 20. 121 20. 12llll !!I 5. l!i Y.i5/ 14/86 11 ; 1!10 833 48 110 9.6 19.2 19. 2121 Qi 5.0 l!i5/ 14/86 17:0121 835 50 113 Ul. r2i 20.0 20. IZliZl 0 6.5 V.l5/ 1. 4/86 23: 0!21 837 51 111 1Ql. 2 20.4 20.40 0 .,. 1:: ..J • .....J DAILY AVERAGE VALUES 19.90 !!l 1::' :::: ....J. ,_1 12l5/ 15/86 05:00 839 49 109 9.8 19.6 19.60 0 4.5 1!!5/ 15/86 11 : 1210 841 47 111!1 9.4 18.8 18.80 Ql 5.0 !li5/ 15/86 17: t!i0 843 47 113 9.4 18.8 18.80 1!1 6.5 1Zl5/ 15/86 23:00 845 C'~. ;,::}.4. 112 HS. 4 2r21. 8 21!1. 81!1 0 6.0 DAILY AVERAGE VALUES 19. 51!1 0 c:· = u. "-' 1215/16/86 1!15: 1210 847 51 1f!l9 lfll. 2 2QJ. 4 20.40 !2l 4.5 V.l5/ 16/86 11:00 849 48 11!19 9.6 19.2 19. 2Jll l!i 4.:: 1!15/ 16/86 1 7: r21r2i 851 49 11 :;:; 9.8 19.6 19.60 121 6.!5 12l5/ 16/86 23: v.HZI 853 51 113 10.2 20.4 20. 41Zl iZl 6.5 DAILY AVERAGE VALUES 19.90 Ill ~· C' -..;. -· f(.i5/ 17/86 !ll5: 00 655 49 11121 9.8 19.6 19.60 0 5.e !ll5/ 17/86 11:00 857 47 110 9.4 18,8 18. Sill !Zl 5.0 05/17/66 17:00 859 50 115 HI. !21 2sll.0 20. 0Y.i Y.l 7.!5 !!l5/1 7/86 23: Jli0 861 64 113 12.8 25.6 25. 6!21 Ql .. =:: c .... DAILY AVERAGE VALUES 21. 01Zl Y.1 6. 12• 1!15/ 18/86 1215: tZil!i 863 6t!l 1 1!2J 12. 121 24.121 24. 0!21 !21 5. Q-; 05/18/86 11: 0121 865 56 110 11.2 22.4 22. 4121 1!1 5. l~ 1215/18/86 1 7 : f!llll 867 59 115 11.8 23.6 23.60 I! I 7.'::. !2l5/ 18/86 2::s: 0v.s 869 7121 113 14.t!l 28.0 28. Jll0 0 6. !:. DAILY AVERAGE VALUES 24. 5121 !2! 6. Q; 1215/19/86 Y.>5: 0!21 871 65 11121 13. !21 26. 121 26. llllli Ql 5. e. 1215/19/86 1 1 : IlliZI 873 59 11219 11.8 23.6 23. 6121 j~l 4.:: Ql5/ 19/86 17: 01:':? 875 64 115 12.8 25.6 25. 61!1 Qi -= I • '- 1Zi5/ 19/86 23: tlil!l 877 84 113 16.8 33.6 33. 6Qi Ql 6.:: DAILY AVERAGE VALUES 27.20 Ill "" -...JCI~ !!15/29.1/86 Y.S5: QHZI 879 76 11219 15.2 30. 'l 3111.40 Ill 4.~ 1215/2121/86 11 : l!i~~l 881 67 1.Hl 13.4 26.8 26. 8!!1 Ill 5. f (15/2~!1/86 17: V.Hii 88:!. 71 115 14.2 28.4 28. 4!ll Ill i :::' I • - k!15/ 2!Zl I 86 2 :!. : 121 !Zl 885 85 112 1 7. Ill 34.0 34. Ql!!i 0 6. (' DAILY AVERAGE VALUES 29. 9!.!1 !ZI 5.E ALAS I< A POWEF-< AUTHm~ITY TEMP/STAGE STUDIES F'age 1"" ,_) DATA REPORT FOR DATAPOD DP211SG -· STAGE AND TEMP. RECORDER 12!2-1!19-8/ DATA FILE NFORI<J!l2 BRADLEY LAI<E HYDRO PROJECT START: 1!11/312!/86 11: 0V.i NORTH FORK OF BRADLEY RIVER STOP: 1214/23/85 11 : Y.i!2i STAGE=DEPTH+G!!l OISCHG=G1*CDEPTH+80)AG2 GfZI::.:: l!i 61= Ql G2= 0 DEPTH STAGE DISCHG TEMP DATE TIME BYTE RAW DATA MV INCHES IN. CFS DEG c -------------==== ========== ==== ====== -----====== ---------------------------- !1.15/21 i86 l2l5: fila 88"1 77 11!19 15.4 31!1. 8 31o. Sft.l Ql 4.5 !!15/21/86 :1. 1 : 1!1121 889 69 11!19 13.8 27.6 27. 610 (!I 4.5 1Zi5/21/86 1 7: f31!! 891 73 115 14.6 29.2 29.2121 Q! 7.5 Y-!5/21/86 23: IZiQ! 893 94 112 18.8 37.6 37.60 121 6. l!i DAILY AVERAGE VALUES 31. 3121 Ql 5.6 1!15/22/86 1215: 1!1121 895 87 1QI9 17.4 34.8 34. 81!! 0 4.5 (!15/22/86 11: Y.i0 897 76 110 15.2 30.4 312'1. 4QI 0 5. fZI }.::'15/22/86 17: 121!21 899 80 115 16.121 32. e1 32.1210 I !I 7.5 1215/22/86 23: 0lZ! 91211 99 112 19.8 39.6 39.6121 Ill 6. !2! DAILY AVERAGE VALUES 34. 2121 12i 5.8 lZl5/2::.\/86 ~255: 1!10 91213 94 110 18.8 37.6 37.60 0 5. QJ {215/23/86 11 : Y.ll2l 91215 81!1 1 1 1 16. !21 32. ~i 32. 0!21 fZl 5.5 !ZI5/Z5/86 17: 12H<? 91!17 85 116 17.0 34. 1!1 34.1210 Y.l 8.0 1!15/23/86 23: V.l!ll 91219 11!13 113 20.6 41.2 41. 21!1 1!1 6.5 DAILY AVERAGE VALUES 36.20 0 6"3 (!15/24/86 1!15 : ill Ill 911 97 109 19.4 38.8 38. 812! V.l 4.5 1-!15/24/86 11:00 913 85 110 17.0 34. 121 34. V.IQI I!! 5. !21 i!l5/24/86 1 7: 1!11!1 915 9-.; .... 116 18.6 37.2 37.20 Y.l 8. QJ V.i5/24/86 23: 01!1 917 115 113 23.0 46.0 46. 0Y.l 0 6 ""' . ....~ DAILY AVERAGE VALUES 39. 01!1 Ill 6.10 05/25/86 Y.l5: 00 919 105 110 21.0 42.0 42.00 0 5. Ql !215/25/86 11 : Ql!!l 921 95 112 19. !21 38 .. £1 38. 1211!1 1!1 6.0 1!15/25/86 17:010 9"""' .._._, HJ2 116 2!21. 4 40.8 40. 8121 1!1 8. Ql 1!.15/25/86 23: !211!1 925 116 113 23.2 46.4 46. 4121 0 6.5 DAILY AVERAGE VALUES 41.80 121 6.4 05/26/86 Ql5: lZIIZI 927 11217 1 1 1 21.4 42.8 42.80 10 5.5 (115/26/86 11 : l!lf.!l 929 93 111 18.6 37.2 37. 2!21 0 r:: .,. ...J • ...J 1215/26/86 1 7: I!IQI 931 95 115 19.0 38. 1!1 38.00 121 7.5 !215/26/86 23: 1210 933 109 113 21.8 43.6 43.60 !21 6.5 DAILY AVERAGE VALUES 4121. 41!1 121 6.3 1!15/27 /86 05: !211!1 935 102 110 20.4 40.8 40. 81!1 0 5.0 !Zl5/27 /86 11 : 1!1121 937 93 111 18.6 37.2 37.20 121 I:" C' ,_,_._, 1!15/27 /86 17: 01!1 939 98 116 19.6 39.2 39. 2!21 121 8.0 ~<.'15/27/86 2~': V.l0 941 11!)6 113 21.2 42.4 42. 41!1 0 6.5 DAILY AVERAGE VALUES 39.9121 121 6 -.; . ._. 05/28/86 !Zl5: 1!11!1 943 98 111 19.6 39.2 39.20 0 C' 1::' ...Jo...J 1215/28/86 11 : i!HZI 945 91!1 11.2 18. 121 36. !21 36. !ZIIE! 121 6. 121 05/28/86 17: Qlf!l 947 96 118 19.2 38.4 38. 4!!1 !!I 9. l!l !1.15/28/86 z~;: loQi 949 117 114 23.4 46.8 46.817.1 Y.i 7. Ql DAILY AVERAGE VALUES 4!21. 11!1 !Zl 6.9 ALA~KA ~UW~k AUIHURliY TEMP/STAG~ STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 16 !212-!2!9-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*(DEPTH+G0)AG2 DATE TII'1E BYTE RAW DATA MV --------------------------========== ==== GIZl= 0 DEPTH INCHES ------------ ~15/29/86 05: !c!H!l 951 109 111 21.8 43.6 DAILY AVERAGE VALUES DATA FILE NFORK02 START: 01/30/86 11:00 STOP: 04/23/85 11:00 Gl.= IZ1 STAGE IN. ===== 43. 6#2i 43. 6J2J G2= Ill DISCHG CFS ------------ TEMP DEG C ---------- 5.5 5.5 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 1 1!12-!!!9-8" BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*(DEPTH+G0>~G2 Gl!l= 0 BEGIN OBS : END OBS :STOP AT 15:45 DATE TIME -------------------------- !215/29/86 12: ll10 V.l5/29/86 18: !ZH!l !!15/31!1/86 01!1: V.lfZI ~!i5/ 30/86 (il6: 1210 Y.l5 / 312' /86 12: QJY.l Y.!5/31!1/86 18: Qlj,!J ~15/:31 /86 121!21: 0121 lll5/31/86 1216: !2lf21 f(J5/31 /86 12: 01ll !215/31/86 18: 12!!21 !!16 I 1!11 I 86 ~~~0: !!Ill! !216/!ZJ 1/86 06: 00 !!16/1!11/86 12:0121 !216/!!11 /86 18: 00 ~~16/V.i2/86 !ZI!ll! !21125 06 / Ql2 I 86 1Zl6: 1~0 1216/02/86 12:00 06/1212/86 18: I!HZl 1!16/1213/86 1211o: 0121 ~96/1!53/86 06: 0!Zf !Zl6/Y.I3/86 12: 01!1 Ql6/l!i3/86 18:!21QI 1216/ !1.14/86 l!f(il: £10 ~2i6/fll4/86 1216: ltH!I Ql6 / ~~>4 /86 12: ~!il!l f!i6/1!14/86 18: ~!jf!l 12i6/l!i5/86 Y-1!!1: 121!21 1!16/1!15/86 Ql6: 12>1!1 1!16/1!15/86 12: l!li!l r!16/IZI5/86 18: !2111.1 BYTE RAW DATA ========== MV DEF'TH INCHES ====== 1 99 112 19.8 39.6 3 104 118 20.8 41.6 5 7 9 11 13 15 17 19 DAILY AVERAGE VALUES 116 114 112 112 11!12 112 99 115 DAILY 1QJ9 113 11!11 112 23.2 22.4 21!1. 4 46.4 44.8 40.8 19.8 39.6 AVERAGE VALUES 21.8 21!!. 2 43.6 40.4 93 112 18.6 37.2 91 115 18.2 36.4 DAILY AVERAGE VALUES 21 99 115 19.8 39.6 23 97 112 19.4 38.6 25 67 112 17.4 34.6 27 86 115 17.2 34.4 DAILY AVERAGE VALUES 29 31 33 35 67 113 63 111 76 111 74 114 D?~ILY 37 77 113 39 74 112 17.4 34,8 16.6 33.2 15.2 30.4 14.6 29.6 AVERAGE VALUES 15.4 14.6 31!1. 8 29.6 41 70 112 14.0 28.0 43 76 114 15.2 30.4 45 47 49 51 53 55 57 59 DAILY AVERAGE VALUES 87 114 87 112 SIZl 112 88 115 DAILY 91 113 85 112 75 112 78 116 DAILY 17.4 34.8 17.4 34.8 16.1!1 32.~!1 17.6 .2 AVERAGE VALUES 18.2 36.4 17. Ill 34. 0 15. 0 31!1. 0 15.6 31.2 AVERAGE VALUES DATA FILE NFORK03 START: 05/29/86 12:00 STOP: 08/06/86 12:00 G 1 = IZl STAGE IN. ===== 39. 6Y.i 41 • 6121 41!1. 6121 46. 4!2.1 44. 61!1 4!21. 8121 39.60 42.9121 43. 6!21 4£J. 41!1 37. 2QI 36.40 39. 41Zi 39. 6121 38 .. 80 34. 81!1 34. 4Ql 36.90 34.80 33. 2QJ 30.40 29. 61P 32. !!liZ! 30.80 29.60 28. !!10 3k1. 41!1 29.70 34.80 34.8121 32. 1?.11!1 35. 2121 34.20 36. 4121 34. !210 312i • i!li!i 31. 2~!i 32. 91!1 62= IZl DISCHG CFS ====== Ill 0 0 Ill Q! 0 121 0 Ill I! I 121 0 IZI Y.l IZI IZI IZI !:'!I 0 I:': I TEMP DEG C .. ____ _ --·--- 6. IZI 9.!2} 7.5 6. Iii 6. r!l 7.5 6.6 6.5 6. l!l 6. !!I 7'. 5 6.5 7.5 6. !ZI 6. Ql 7.5 6.8 6.5 ""' c::-.....~. _, 5.5 7. ~~ 6. 1 6.5 6.0 6. 12) 7 .l?.l 6. 4 7. Qi 6. ~~~ 6. ~21 7.5 6.6 6.5 6.0 6. !?l 8.0 6.6 HLHbKA ~UW~K AUIHUH11Y I~M~/biHb~ biUU1~b DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER rage .:.. !212-09-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>~G2 G0= l!l DATE TIME ======== ===== t~l6 / !216 / 86 !2lfil: tZII!i j~l6 /1216/86 !!16: I.!H!l !2i6/!Zi6/86 12:00 !2l6/Qi6/86 18: QIQI IZI6/!ll7 /86 121121: 1£11!1 06/07/86 !216: 00 ill6/QI7/86 12:!2t1Zl t::I6/Y.I7/86 18:00 ¥.16 I 1!18 I 86 l:iJ0: 0121 ¥.16/~!18/'86 1!16: 00 Ql6/lll8/86 12:00 1216/!!18186 18: 0~1 !216/1!19/86 1211!1: k10 06 11{)9/86 !06: 00 1Zl6 I !219 I 86 12: I!~Y.l fll611ll9/86 18: Ql0 Ql6/ 1Qii86 00:0121 !!16/ Hl/86 fZI6: 00 1!16/ li(J/86 12:0121 1216/llo/86 18:1£H!I (216 I 11/86 1210: ltlJ!I !216/11186 06:!2H21 1,!)6/ 11/86 12: 1!10 1216/11/86 18: 00 Qi6/ 12/86 0Y.I! 00 06/12/86 1!16;QI!Zl !!16/ 12/86 12: 0£1 i216/ 12186 18: 1!1121 t!i6/ 13/86 121121: IZIIZI ~::16/13/86 f.!l6:0t21 ~~16/13/86 12:!211!1 1216113/86 18:!!1121 BYTE 69 71 73 75 77 79 81 83 85 87 89 91 93 95 97 99 11!11 11213 105 HiJ7 109 111 113 115 117 119 121 123 RAW DATA MV DEPTH INCHES ========== ------------ 89 115 84 111 75 1.11 71 114 DAILY 72 114 7£1 113 69 114 84 119 DAILY 100 115 95 112 9Y.I 112 89 115 DAILY 87 114 82 112 73 113 70 117 DAILY BY.! 117 75 113 72 113 71 119 DAILY 89 118 87 113 76 113 75 118 DAILY 84 116 78 113 72 113 71!1 116 DAILY 75 117 72 1l.2 69 112 68 118 DAILY 17.8 35.6 16.8 33.6 15.0 31!1. 0 14.2 28.4 AVERAGE W\LUES 14.4 28.8 14.0 28. (!1 13.8 27.6 16.8 33.6 AVERAGE VALUES 2t.'!l.0 40.0 19.0 38.13 18.0 36.0 17.8 35.6 AVERAGE VALUES 17.4 34.8 16.4 32.8 14.6 29.2 14.0 28.0 AVERAGE VALUES 16.0 15. 121 14.4 32.~1 3121.0 28.8 14.2 28.4 AVERAGE VALUES 17.8 35.6 17.4 34.8 15. 2 3£1. 4 1 5 • 121 30 • Lif AVERAGE VALUES 16.8 33.6 15.6 31.2 14.4 28.8 14 • 121 28 • 121 AVERAGE VALUES 1 5 • 121 3(:!1 • Y..l 14.4 28.8 13.8 27.6 13.6 27.2 AVERAGE VALUES DATA FILE NFORK03 START: 05/29/86 12:00 STOP: 08/06186 12:00 61= v.s STAGE IN. ---------- 35. 61!1 33. 6121 3121. 01!1 28.40 31.9l21 28. BIZI 28. 0!21 27.60 33.61ZI 29.50 40.00 38. 01!1 36. 0Y.I 35. 6Lil 37.40 34.80 32. 8£1 29.20 28.00 31.20 32. 0!21 30. I!HZI 28.80 28.4121 29.8121 35.60 34.80 3121. 4!21 30.1210 32. 71.!1 33. 6QI 31.20 28.80 28. t!lt!l 3Y.i. 41!1 3 rll • 1211!1 28.80 27.6121 27.20 28. 4!!1 G2= !!l DISCHG CFS ====== 0 0 Y.l Ill Ill IZI til 0 0 121 !!I 121 0 !21 121 121 TEI"IP DEG C ---------- ~1. 5 5. =t 5.5 7. l!i 6.4 7. 121 6.5 7. 1!1 9. ::. 7.5 7 c· • ..J 6. 12i 6. IZI 7.5 6.8 7. 1.!1 6.0 6.5 8.5 7.0 8.5 6.5 6.5 9 "''' o..J 7.8 9. Y.! 6.5 6.5 9. Y.l 7.8 8.0 6.5 6.5 8. ~~~ 7.3 8.5 6.0 6. l!l 9. Ill 7.4 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER Page 3 Ql2-l2l9-8~ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1•tDEPTH+G0>AG2 G0= IZl DATE TIME -------------------------- !2l6/l4/B6 1!hcl:00 l2l6/ 14/86 1!16: 12>12! iZ16/ 1 4/86 1 2 : 0!!> 1!16 I 14/86 18 : !Zli!l !!16/ 15/86 00: l!ll!l 06/15/86 12>6: 00 ~16/15 / 86 12 : 1!10 1!16/15/86 18:0121 i!i6/ 16/86· l!IQl: 00 i!i6/16/86 1!16:t!l!!l 06/16/86 12:00 06i16/86 18:0121 1!!6/ 17/86 !!HZI: 1210 1216/ 17/86 06: 1!10 !!16/17/86 12:121121 1216/17/86 18:00 QJ6/ 1.8/86 00: 0Y.I 1!16/ 18/86 06: f!l0 !216/18/86 12:0121 1!16/18/86 18: 121!21 ~16 I 1 9 I 86 I!H!l : !210 !:.'16/19/86 !!16:01{) 1!16/19/86 12:1!11!1 lZl6/19/86 18:1!l!!i J-!16/21!1/86 ~110: Qll!l fi.l6/21!i/86 !Zl6: J-!'0 Ql6/20/86 12: 1211!1 l~i6 / 2l!l /86 18: 0121 t!i6/21 /86 !ZII!I: 121121 Qlb/21/86 I!J6:01?i Ql6/21/86 12: l!iY.I 06/21/86 18:121121 BYTE ==== 125 127 129 131 133 135 137 139 141 143 l'l-5 147 149 151 153 155 157 159 161 163 RAW DATA MV DEPTH INCHES -------------------------------- 75 117 74 114 72 114 72 118 DAILY 15.0 30.1Zl 14.8 29.6 14.4 28.8 14.4 28.8 AVERAGE VALUES 82 118 16.4 32.8 83 115 16.6 33.2 76 115 15.2 30.4 86 123 17.2 34.4 DAILY AVERAGE VALUES 109 120 21.8 43.6 108 114 21.6 43.2 100 115 20.0 40.0 102 122 20.4 40.8 DAILY AVERAGE VALUES 116 120 113 115 108 116 23.2 22.6 21.6 46.4 45.2 43.2 112 120 22.4 44.8 DAILY AVERAGE VALUES 116 117 110 114 103 114 10!21 117 DAILY 23.2 22.121 46.4 44.0 21!1.6 41.2 20.0 4!!1. 0 AVERAGE VALUES 165 100 116 20.0 40.0 167 96 113 19.2 38.4 169 92 113 18.4 36.8 171 91 121 18.2 36.4 173 175 177 179 181 183 185 187 DAILY AVERAGE VALUES 110 118 120 113 110 114 1Ql4 115 DAILY 1121121 115 95 113 90 113 84 115 DAILY 22.121 44.0 24.1..il 48. 12> 22.l!l 44.0 2&21. 8 41. 6 AVERAGE VALUES 20.0 41!1. 0 19.10 38. 0 18 • 1!1 36. Ql 16.8 33.6 AVERAGE VALUES DATA FILE NFORK03 START: 05/29/86 12:00 STOP: 08/06/86 12:00 61 = !!I STAGE IN. ---------- 31!1 • 1!11!1 29. 6121 28.8121 28.80 29. 31~ 32. 81!1 33. 2f0 3121. 40 34.40 32. 71!1 43.6121 43. 2Y.J 40.00 412!. 8121 41.90 46. 4&!1 45. 2121 43. 21!1 44.8121 44.90 46.40 44.00 41.20 40. fZIQI 42.90 40.00 38.40 36.80 36.40 37.90 44.00 48. I!HZI 44. J!lf!l 41.60 44. 412l 41!1. 1!10 38.0121 36. !!llo 33. 6121 36. 91!1 G2= 0 DISCHG CFS ------------ 0 !21 0 121 0 0 121 10 0 0 Ql 0 0 V.l 1!1 TEt1F' DEG C ---------- 8.5 7.0 7. I!J 9. Qi 7.9 9. Ill 7.5 7.5 11.5 8.9 10.0 7. !21 7.5 l!Zl. Ql 7.5 8.0 HI. 0 8.9 8.5 7. 121 7.0 8.5 7.8 8. 121 6.5 6.5 10.5 7.9 9. lli 6.5 7. 125 7.5 7.5 6 .:::· • ....! 6.5 7.5 7.(!) ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 4 102-1!!9-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*CDEPTH+G0)AG2 G0= 1!1 DATE TIME -·------------------------- 1::16/22/86 £10: Y.l0 '!i6/22/86 1216: f!il!l 1.!16/22/86 12:00 Y.l6/22/86 18: '!il21 1!16/23/86 1!10: 0121 1216/23/86 06:00 06/23/86 12: I!JI!I 1!16/23/86 18:0121 1216/24 I 86 0Y.I: Jl)0 1!16/24/86 £16:1!1121 1!16/24/86 12: 00 06/24/86 18:0121 1!16/25/86 l!lf21:00 1216/25/86 l!i6: 00 06/25/86 12: 0f2i 06/25/86 18:00 t-!;6/26/86 00:00 06/26/86 !!16: V.IQI !216/26/86 12: 12l!ZI 1!16/26/86 18: !.!10 !Zi6/27/86 Qll!l: 01!1 !l.l6/27 /86 lc'J6: 1210 06/27/86 12:0121 06/27/86 18: ~30 06/28/86 0121: 0~!1 1!16/28/86 06:0121 06/28/86 12:01!1 1216/28/86 18: V.1!2l V.i6 I 29/86 !Zil?.l: t!ll21 1216/29/86 1!16: J!J~!I V.>b / 29/86 12: 121121 Qlb/29/86 18:1210 BYTE 1.89 191 193 195 RAW DATA ========== 81. 115 79 114 74 114 76 118 MV DEPTH INCHES ====== 16.2 32.4 15.8 31.6 14.8 29.6 15. 2 3!21. 4 DAILY AVERAGE VALUES 197 83 119 16.6 33.2 199 81 114 16.2 32.4 201 80 113 16.0 32.0 203 76 117 15.2 30.4 205 2!217 21219 211 213 215 217 219 221 223 225 227 DAILY AVERAGE VALUES 78 116 76 113 73 113 70 116 DAILY 15.6 31.2 15.2 30.4 14.6 29.2 14.!21 28.!21 AVERAGE VALUES 71 115 14.2 28.4 69 114 13.8 27.6 65 114 13.0 26.0 68 121 13.6 27.2 DAILY AVERAGE VALUES 82 120 83 115 80 114 78 118 DAILY 16.4 32.8 16.6 33,2 16.0 32.0 15.6 31.2 AVERAGE VALUES 229 87 119 17.4 34.8 231 91 113 18.2 36.4 233 85 113 17.0 34.0 235 86 120 17.2 34.4 DAILY AVERAGE VALUES 237 89 119 17.8 35.6 239 89 115 17.8 35.6 241 88 115 17.6 35.2 243 90 117 18.0 36.0 DAILY AVERAGE VALUES 245 97 117 247 99 115 19.4 19.8 38.8 39.6 249 95 115 19.0 38.0 251 97 119 19.4 38.8 DAILY AVERAGE VALUES DATA FILE NFORK03 START: 05/29/86 12:00 STOP: 08/1!16/86 12:00 Gl = 12i STAGE IN. ---------- 32. 412! 31.60 29. 6121 3QI. 41!1 31.00 33.20 32.40 32.00 30.4121 32.00 31.20 30.40 29. 21!1 28. 01!1 29.70 28.40 27.60 26.00 27.20 27. 3121 32. 81!1 33. 2121 32. l!lfZI 31. 2121 32.30 34. St!l 36. 4121 34. 12!1!1 34. 4121 34. 91ZI 35.60 35. 61!1 35. 2J2S 36. !!H!l 35. 6121 38.80 39. 61!1 38. !211!! 38. 8!21 38.80 (i2= 0 DISCHG CFS ------· ------ 121 121 121 0 0 0 0 0 Ql Ill IZ! 0 !Zi 0 Y.l TEt1P DEG C ===== 7.5 7. iZl 7. (1 9. !!I 7.6 9.5 7.0 6.5 8.5 .. ?. 9 8. Qi 6.5 6.5 8. !Zi 7.3 7.5 7.0 7. 1!1 1!!!.5 8. 121 7. 10 9. ill 8.4 9 C' • ....J 6.5 ' C' o • ....J 10.0 8. 1 9. :-; 7.5 7.5 8.5 8.3 8.5 7.5 7.5 9.5 8.3 ALASKA POWER AUTHORITY fEMP/SfAGE SfUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 5 1~12-1!19-81 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1•CDEPTH+G0)AG2 DATE TIME -------------------------- J2)6 I:::.:;!!!/ 86 i:~10: 12!121 Ql6/312l/86 fil6:!2!1!1 ~!16/3!?i/86 12:00 I06/3Y.I/86 18: !21121 07 I Q~ 1/86 !2113: 1210 fll7 101186 06: 00 1217 I 01 I 86 12: fil!ZI IZ17/1:?1/86 18!121!.!1 1217 1(12186 ~::11!1: 00 !!17 /1!12/86 !!16: 1211!1 07 /~!12186 12:00 1!17 11212/86 18: f!JIZl 07/03/86 1!1121: Y.ll!l 1217/!!13/86 1:~16: 0!21 1217 /1!13186 12: 01ZI 07/03/86 18: 0Ql 1217/1214/86 0121:00 1!17 /!214/86 £16: 1!10 l!i7 I ~~>4/86 12: !210 1!>7 I 1214/86 18: 121!21 1!17 I !!15/ 86 .L~Ill: 00 ~.!17 /1215186 1216:00 1!17/1215/86 12: lll0 1?.17 /1!15186 18: 1!.10 V.17 h~l6/86 V.HZI: 0121 07 /1~16 I 86 06: I!H!I 1217 /~!16/86 12: Ql0 !!17/1!16/86 18:Y.H!I ~!i 7 I Y.f7 / 8 6 121121 : 1!1121 Qi7 /~?7 /86 1216: 0!!1 (!17 /QI? /86 12: 0Qi yJ7 I !217 /86 18: !lh-3 BYTE 253 255 257 259 261 263 265 267 269 271 273 275 RAW DATA --------------------1!2S5 118 MV 21.1!! DEPTH INCHES ====== 42. ~!I 105 115 21.0 42.0 102 115 20.4 40.8 102 121 20.4 40.8 DAILY AVERAGE VALUES 115 121 116 116 112 115 104 117 DAILY 103 118 102 115 102 116 104 118 DAILY 23.121 46.12S 2:.t. 2 46.4 22.4 44.8 20.8 41.6 AVERAGE VALUES 20.6 41.2 2121. 4 4Y-i. 8 20. 4 41tl. 8 2121.8 41.6 AVERAGE VALUES 277 105 117 21.0 42.0 279 102 114 20.4 40.8 281 97 114 19.4 38.8 283 96 122 19.2 38.4 285 287 289 291 293 295 297 299 31211 3kl3 305 31!17 3!!19 311 313 315 DAILY AVERAGE VALUES 105 121 107 115 102 115 10!21 122 DAILY 1!218 120 109 114 21.121 42.0 21.4 42._8 20.4 40.8 2121.kl 40.0 AVERAGE VALUES 21.6 21.8 43.2 43.6 101 115 20.2 40.4 101 119 20.2 40.4 DAILY AVERAGE VALUES 11215 119 111 116 21.121 22.2 42.0 44.4 109 116 21.8 43.6 109 118 21.8 43.6' DAILY AVERAGE VALUES 111 118 H!l9 115 21.8 44.4 43.6 105 115 21.0 42.0 99 118 19.8 39.6 DAILY AVERAGE VALUES DATA FILE NFORK03 START: 1215/29/86 12:00 STOP: 08106/86 12:00 STAGE IN. ---------- 42. 121!2! 42. 1!10 4121. 80 40. 8tZI 41. 4121 46.00 46.40 44.8121 41.60 44.7121 41. 2121 4f!l. 80 40. 81!1 41. 6121 41.10 42. 121!21 40. 812l 38.8121 38.40 4121. 1210 4 2. 1!1121 42. 81!1 40.80 40. IZI!Zl 41.40 43. 2121 43. 61!1 40. 4121 4!21. 412! 41. 9!2i 42.!21121 44.410 43. 6!!1 43.60 43. 41!1 44. 4!21 43. 6121 42. ~!)!!) 39. 6~:1 42. 4121 62= ~~~ DISCHG CFS ====== IZl 0 0 0 121 0 0 0 f!l Ql 121 0 121 0 V.i TEMP DEG C ===== 9. fl 7.5 7.5 11!1.5 8.6 1121. 5 8.0 7.5 8.5 8.6 9.0 7.5 8. 121 9. i!i 8.4 8.5 7. IZl 7. IZ> 11.0 8.4 11!1.5 7.5 7.5 11. V.l 9. 1 7.5 9.5 8.5 9.5 8. 1!1 8. 121 9. Ql 8.6 7.5 7 .:;· . ~· 9. Ill 8.3 ALA~KA ~UW~K AUIHUKliY I~M~/~IAb~ biUUl~b DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 6 1!12-1219-8: BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 DATE TI1'1E --------------------------- 07 I Y.l8 /86 00: ~~)i!i IZ17 I QIS I 86 1!16: 1!1121 ~~17 /~18/86 12: 011.1 !!i7/08186 18: liJIZI Y.l7 I 1219 I 86 1211!1: flJ!ZI 11.17109186 Qi6:00 QI71!ZI9/86 12:01!1 Ql7/~~19 186 18: !210 (17 I Hl/86 00:00 1!17 I 11!1186 1!16: 0Ql !Zl7 I 11ZII86 12:00 1217 I 11!1/86 18: I!I!ZI 1!17 I 11186 0v.l: 0lil 07 I 11 I 86 1216; 00 r.ZI7 / 11 I 86 12: 01!1 Ql7 I 11186 18:00 V.i7 /12/86 00:00 iZ17 I 12186 06: '!HZ! 07/12/86 12:00 1::17/12/86 :1.8:1210 !!17 I 13/86 1!10: V.10 1!17 I 13/86 186:00 07113/86 12:!210 !!J7/13/B6 18:1ZIIo iZl7 /14/86 11.1~?: 00 07 I 14/86 1!16: QlQI 1217/14186 12: 121r21 !ll7/14186 18: QH21 07115/86 f210:V.IQI 1217/15/86 1!16:~~~~!1 07/15/86 12:V.Illl 07 I 15/86 18: !!IV.I BYTE 317 319 321 323 325 327 329 331 333 335 337 339 341 343 345 347 349 351 353 355 357 359 361 36~5 365 367 369 371 373 375 377 379 RAW DATA MV DEPTH INCHES ========== ==== ====== 103 118 102 114 98 114 93 118 DAILY 94 117 93 114 86 115 85 119 DAILY 90 119 89 114 84 114 84 122 DAILY 96 122 100 116 94 116 92 123 DAILY 100 121 2111.6 41.2 2121.4 4!!1. 8 19.6 39.2 18.6 37.2 AVERAGE VALUES 18.8 37.6 18.6 37.2 17.2 34.4 17. 121 34. 0 AVERAGE VALUES 18.0 36.0 17.8 35.6 16 .. 8 33.6 16.8 33.6 AVERAGE VALUES 19.2 38.4 2G:1. 0 40 • IZI 18.8 37.6 18.4 36.8 AVERAGE VALUES 20. Y.t 40.0 101 115 20.2 40.4 93 116 18.6 37.2 90 121 18.0 36.0 DAILY AVERAGE VALUES 92 119 91 115 87 115 82 117 DAILY 80 117 79 114 76 114 18.4 36.8 18.2 36.4 17.4 34.8 16.4 32.8 AVERAGE VALUES 16.0 15.8 15.2 32.0 31.6 30.4 75 121 15.0 30.0 DAILY AVERAGE VALUES 84 122 89 117 88 116 84 118 DAILY 16.8 33.6 17.8 35.6 17.6 35.2 16.8 33.6 AVERAGE 'VALUES DATA FILE NFORK03 START: 05/29/86 12:00 STOP: 1218/06/86 12:00 81= 0 STAGE IN. ===== 41. 21Zl 4!il. 8!21 39. 212l 39. 6!21 37. 6!21 37.20 34.40 34.00 35.80 36.00 35. 6121 33. 6121 33.60 34. 7!21 38.40 40.00 37.60 36. 8V.l 38.20 40.00 40. 4121 37.20 36. 0Y.I 38.40 36. 8121 36.40 34.80 32.80 35. 2l!l 32.00 31.60 30.40 3121. 121121 31 • 121121 33.60 35.6121 35. 2Qj 33.60 34. 5!21 62= 121 DISCHG CFS ------------ 0 0 0 121 Ill 0 !!I 121 0 0 0 {!I 0 Ql I! I TEMP DEG C ----------- 9. l!l 7. V.l 7. IZI 9. !!I 8. 12i 8.5 7.0 7.5 9.5 8. 1 9.5 7. l!l 7. 121 11. 121 8.6 11. Qj 8. '~ 8. 121 11.5 ':Y. 6 H?.5 7.5 8. 12! HI. 5 9. 1 9.5 7.5 7.5 8.5 8.3 8.5 7. V.! 1121.5 8. :::;. 11. 121 8.5 8. Q! 9. ~21 9. 1 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER F'age 7 (!12-!!19-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 GV.>= !v D~"\TE TIME ------·-------------------- !!17/ 16/86 !211~1: 00 i217 / 16/86 €16: I!H!I Ql7 /16/86 12: 0!!1 1217/16/86 18:01!1 !07 /17/86 1211:!1: IlliZI !'217/17/86 !!16:00 !217/17/86 12:00 (1.l/l.7/86 18:Y.H!I 1217/18/86 !2H!I:01Zi !!17 I 18186 1216: Qll!l ~2i7/18186 12:!21(!1 !ZI?/18/86 18:1!1121 12!7 I 1 9 /86 1210: i!llll 07/19/86 IZI6:tll0 !217 I 19/86 12: 01!1 (!li' I 19/86 18: !!H!i !!57 /2~!1/86 !!10: 00 !!17/2!!1/86 1!16: £::11!1 ~:>7 /21Zi/86 12: 01ZI ~':i7 /20/86 18: i!l!!l 07/21186 00: 01!1 f-17/21186 1216:~10 V.l7/21/86 12:0£1 07/21/86 18: IZiiZI 1217122/86 !ZIQI: Y.l$!1 1!>7 /22 I 8 6 1!16: 0121 l!i7 /22/86 12: IZIY.l ~17./22/86 18: l!iQl !!!7 I :Z 3 / 86 IZI!!I : 10 Ql i:~i7/2:3/86 1216:1210 !217/23/86 12:0!2i 1!17/23/86 18: f(.il!l BYTE RAW DATA MV DEPTH INCHES ==== ========== ====== 381. 383 385 387 389 391 393 395 397 399 401 41!13 85 118 84 115 79 115 8!!1 117 DAILY 611 118 79 115 76 115 76 123 DAILY 93 124 95 117 89 1.17 89 123 DAILY 1 7. !!5 34. !!I 16.8 33.6 15.8 31.6 16. !!I 32. l!i AVEHAGE VALUES 16.2 32.4 15.8 31.6 15.2 31.!). 4 15. 2 3121. 4 AVERAGE VALUES 18.6 37.2 19. 121 38. 0 17.8 35.6 17.8 35.6 AVERAGE VALUES 405 97 120 19.4 38.8 407 93 117 18.6 37.2 409 88 117 17.6 35.2 411 91 125 18.2 36.4 413 415 417 419 DAILY AVERAGE VALUES 106 124 11!15 119 Hl3 119 1 J.!S6 121!5 DAILY 21.2 21.0 2121. 6 42.4 42. 121 41.2 21.2 42.4 AVERAGE VALUES 421 108 119 21.6 43.2 423 103 115 20.6 41.2 425 96 116 19.2 38.4 427 94 122 18.8 37.6 429 431 433 435 437 439 441 443 DAILY AVERAGE VALUES lfH 121 11!11 118 101 118 1!!15 119 DAILY 113 118 113 116 1~18 116 11!12 119 DAILY 2Jll • 2 4(!1. 4 20.2 4121.4 2121. 2 40.4 21.!!1 42.!21 AVERAGE VALUES 22.6 22.6 21.6 45.2 45.2 43.2 20.4 40.8 AVERAGE VALUES DATA FILE NFORK03 START: 05/29/86 12:00 STOP: 08/06/86 12:00 81::: Qi STAGE IN. ====== 34.00 33. 61!1 31.60 32. i!ll!l 32.8121 32.40 31.60 30.40 30. 4!21 31. 21!1 37.20 38. 1!10 35. 61?.1 35.60 36.60 38. 8!!1 37.20 35. 2!!1 36.4121 36. 91!1 42. 4~?1 42. !21!21 41.2121 42. 4!25 42. 0!!1 43.20 41.20 38. 4121 37. 6111 40. 1121 4J.:J. 40 4!!1. 4121 4!21. 4121 42. 0121 40. 8QI 45. 21!1 4=.t. :!:t~> 43. 2!!1 41!.1. 8tZI 4::;. 6!21 132= Qi DISCHG CFS ====== Ql 0 1!1 0 V.J iZl QJ 0 121 Qj !!i TEI'1P DEG C ---------- 9" 121 7.5 7.5 8.5 8. 1 9. !21 7.5 7.5 11.5 8.9 12. ~21 8.5 8.5 11.5 1!21. 1 lQI. 1!1 8.5 8.5 12.5 9.9 12. V.i 9 .. 5 9.5 1121. IZI Hi.3 9.5 7.5 8. 121 11.0 9. !!l 10.5 9. !.2! 9. ~:; 9.5 9 <=: ....... 9. l2i 8.0 8. Qi 8.6 ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 8 !!>2-12i9-8' BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0lAG2 DATE TIME ____ .. _____ H_ ------ --··--~--------- 1217/24/86 1210: 121~!1 1!17./24/86 !!16: llil!l ~!17 /24/86 1.2: 01?.5 (.!17 /24/86 18: !!ll21 1!17 /25/86 01!5: I!HZI 07/25/86 !216:0121 IZI:?/25/86 12:01!5 1!17 /25/86 18: 1~10 1!17 /26/86 01!1: !21!~1 Qi7 /26186 !216: 1!11!1 J!l7 /26/86 12: '-'ll!i 1!17 /26/86 18: 00 l!i7 I 2.7/86 1!10: !!1!21 125'7 /27/86 1216: 01!1 1!17/27 186 12: 1!1121 07/27/86 18:!21121 1217/28/86 lZH!I: 1!1121 1!17 /28 I 86 1!16: 121121 07/28/86 12:00 i217 /28/86 18: Y.IY.I 1!17/29/86 V.S!!i: 1210 12i7 /29/86 06: 1!10 !Z17 /29/86 12: 1!1!!1 !!17/29/86 18:1210 ~3J7 I 31!5 /86 Ql!J.I: 1211!1 Cll7 /3121/86 ~~i6: l!H!I !Zi7 /30/86 12: V.l!21 !257 /31Zl/86 1.8: 1211!1 l!t7 /31/ 86 IZil!l: QSQI !2!7 /31 /86 !l!6: l!ll!l 1!17/31 /86 12: 12>1Zi 1217/31/86 18:0Y.J BYTE RAW DATA -------------------- M\i ==== DEPTH INCHES ------------ 445 100 118 20.0 40.0 447 96 116 19.2 38.4 449 91 115 18.2 36.4 451 88 118 17.6 35.2 453 455 457 459 DAILY AVERAGE VALUES 91 119 87 115 78 116 80 118 DAILY 18.2 36.4 17.4 34.8 15.6 31.2 16. 1,!1 :.;2. 1!1 AVERAGE VALUES 461 91 117 18.2 36.4 463 90 116 18.0 36.0 465 87 116 17.4 34.8 467 86 121 17.2 34.4 469 4~'1 473 475 477 479 481 483 485 487 489 491 493 495 497 499 DAILY AVERAGE VALUES 94 120 91 115 84 115 84 122 DAILY 18.8 37.6 18.2 ::::6.4 16.8 33.6 16.8 33.6 AVERAGE VALUES 93 121 18.6 37.2 89 116 17.8 35.6 80 116 16.0 32.0 81 122 16.2 32.4 DAILY AVERAGE VALUES 89 121 83 116 17.8 16.6 35.6 33.2 79 115 15.8 31.6 80 122 16.0 32.0 90 81 76 78 DAILY AVERAGE VALUES 121 117 116 18. ~~ 16.2 15.2 36.0 32.4 30.4 121 15.6 31.2 DAILY AVERAGE VALUES 501 91 120 18.2 36.4 503 81 117 16.2 32.4 505 75 117 15.0 30.0 507 78 121 15.6 31.2 DAILY AVERAGE VALUES DATA FILE NFORK03 START: 05129/86 12:00 STOP: 08106/86 12:00 Gl= 0 STAGE IN. ---------- 41Zi • l!i!Zl 38. 41!1 36. 41!1 35. 21!1 37. 51£! ~;6. 41!1 34. 8!2l 31. 21?.1 32. 1210 33. 6!21 36. 4!!1 :::::6.1!10 34.80 34. 41!1 35.40 37. 6l!l 36.40 33.60 33.60 35. 3!!1 37. 21!5 35. 61Zi 32. 01!1 32.40 34. 3Y.1 35. 61!1 33.20 31.60 32. 0121 33.10 ~56. Ql~l 32.40 3~1. 40 31.2121 32. 5~3 36.4121 3 ~:1 • !Zil!l 31. 2121 32. 5,25 82= 0 DISCHG CFS ====== J!l l!i Y.J 121 0 Ill 0 121 (ij Ql TEMP DEG C ........ , .. __ _ ----- 9. j!! 8. 121 "1. 5 9. !!I 8.4 9.5 -0::: I • ...s 8. !2i 9. ~3 8. :;; 8.5 8. Q! 8. ~::1 10.5 8.8 11!1 • 1!1 7.5 7.5 11. !Zl 9. 1!1 1!21.5 8. 121 8. ~;i 11. 12i 9.4 11!1.5 8. IZI 7.5 11. 1!1 9.3 HI. 5 8.5 8. 1?1 1121. 5 9.4 10. 12l 8.5 8.5 10.5 9.4 ALAS I< A POWER AUTHORITY TEI"IP/STAGE STUDIES Page 9 DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER 02-1Zl9-8·; DATt; FILE NFORK03 BRADLEY LAI<E HYDF<O PRO,JECT START: 05/29/86 12: QIQ! NORTH FORI< OF BRADLEY RIVER STOP: ~-~18/!ll6/86 1 2: 1!1121 ST AGE=DEF'TH+G!!I DISCHG=G1*<DEPTH+G0)AG2 GIZI= 121 Gl.= Ill G2= !Zl DEPTH STAGE DISCHG TEI1P D~~~TE TIME BYTE RAW DATA MV INCHES IN. CFS DEG c ------------------========== ---------------====== ===== -----------·------------- !!18/01 /86 121!21: Ql0 509 85 12!ZI 17.!21 34.121 34. 1!11!1 0 H1. 121 1!18/1211/86 !216: Q!(!l 511 81!1 117 16. !ZI 32.W 32. !!1121 ~~ 8 c· •'-' !ZI8/ 1!11 I 86 12: 1!10 513 75 117 15.0 30.0 30. I!H!l Y.i 8.5 08/1!11/86 18: IZH?I 515 83 121 16.6 33.2 33. 2Q) Q) lQI, 5 DAIL '{ AVERAGE VALUES 32. 3121 0 9.4 1218/1!12/86 01!1: !ZI0 517 84 12Y.l 16.8 33.6 33. 61!1 121 11!1. lZl 1218/1212/86 !Zf 6 : l!l!ZI 519 84 11.8 16.8 33.6 33.6121 IZI 9. 121 !218/02/86 12: 1!10 521 84 118 16.8 33.6 33.60 121 9.0 1218/1212/86 18: 121~3 523 89 122 17.8 35.6 35. 6121 0 11.0 DAILY AVERAGE VALUES 34.10 0 9.8 IZ'!8/QI3/86 00: Y.IJ!f 525 98 120 19.6 39.2 39.2121 Ql Hl. IZl 1218/03/86 !Zi6: Y.H!I 527 98 118 19.6 39.2 39. 2121 Ql 9.0 1218/1213/86 12: Y.l!Zi 529 99 118 19.8 39.6 39.60 J!S 9. Ql Ql8 / tl13 I 86 18: 0121 531 106 119 21.2 42.4 42. 41!1 Y.l c:;1 c:: .. ...., DAILY AVERAGE VALUES 41!!. HI ~~ 9.4 12!8/i!l4/86 f2i!21 : I!! I!! 533 11!16 119 21.2 42.4 42. 41!1 121 9. =; V.l8/V.i4/86 S!l6: 01!1 535 H~ll 116 2l.il. 2 40.4 40. 41!! Y.l 8. V.i 08/1Zl4/86 12: (!jl2! 537 89 116 17.8 35.6 35. 6121 121 8. 121 rtJS/!!14/86 18:00 539 87 119 17.4 34.8 34. 8fl! 12! 9.5 DAILY AVERAGE VALUES 38.30 121 8.8 !!!8/12!5/86 0(~: (11!1 541 87 117 17.4 34.8 34. 81!1 ~!! 8.5 IZ!B/1!15/86 12J6: 1!10 543 81 116 16.2 32!4 32.40 121 8.111 1218/!2!5/86 12: ft.lY.l 545 n.:i 116 15. ~!I 30. 1!1 30. 1!!0 lil 8. Q1 1!18/1!15/86 18: !!10 547 74 119 14.8 29.6 29.60 12! 9 t::· . ....~ DAILY AVERAGE VALUES 31.70 f21 8.5 Ql8/12l6/86 £i lZl : 12ill$ 549 73 118 14.6 29.2 29. 21Zl 121 9. Ql Ql8/ f!l6 I 86 06: Qi~l 551 69 116 13.8 27.6 27.60 0 8. I!! 1::18/1!16/86 12: 12H21 553 66 115 13.2 26.4 26.40 I!! 7.5 DAILY AVERAGE VALUES 27.73 Qi 8 '":• ...... ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER DATA FILE Page 1 iZI2-I!l9-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER START: 08/06186 18:00 STOP: 11/19/86 12:21~1 STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 Gl= Y.> G2== 0 BEGIN OBS :CHAN1=12.8 CHAN2=9.5 USED=555 GAGE=ABOUT 42" END OBS :CHAN1=7.2 CHAN2=3.0 USED=841 POD FLODED-NO DAMAGE DATE T I 1'1E -···--------·-------===== ~18 / !216/ 86 :l. 8: !!lf!i ~.18 I 1!17 I 86 00: QlV.i !liB/ !Zl7 I 86 1216: 1?1121 1218/1!17 /86 12: Qll.(l 1!18 I lll7 I 86 18: 0lil li.l 8 I 1218 I 8 6 !!1121 : !ZS!21 lll8/!l18186 06: 12H!.I 1!18/!!18186 12:1!11!1 IllS/ 1218 I 86 18: 0121 !Zi8/~19/86 00: 1!10 !!i8 I tl19 I 86 1!16: 1!1121 1258/1!19 186 12: 00 fl!8dll9186 18:0!!1 lZ18/ 10/86 1!10: !!It!! ~~18/l.W/86 ~!16: 1210 l?.iS/Hi/86 12:1210 08/10/86 1.8:0121 08/1. 1 /86 QI!ZI: 1!10 1!18 I 11 I 86 1216: IZI!ll 12181 11/86 12: 121!21 IZIS/11186 18:1211!1 1!18/12/86 1210: 1!11!1 Qi8/ 12186 1216: !!!Ill !218/12/86 12:ilillf Ql8/ 12/86 18: !!lt.-9 1!.181 13186 00: I!JY.i !!18/ 13186 1216:1210 1!18 / 1 3 / 86 12 : !!111.1 1!18./ 1 :3186 18: I!H!l BYTE RAW DATA ==== ========== MV ==== DEPTH INCHES ====== 1 65 119 13.0 26.0 5 7 9 11 13 15 17 19 21 23 25 27 29 31 ..,..., ._-.._\ 35 37 39 41 43 45 47 49 51 57 DAILY AVERAGE VALUES 64 118 62 117 6£21 117 62 118 DAILY 66 117 69 116 84 116 91 119 DAILY 89 118 84 117 80 117 81 119 DAILY 81 118 83 117 12.8 25.6 12.4 24.8 12.0 24.0 12.4 24.8 AVERAGE VALUES 13.2 26.4 13.8 27.6 16.8 33.6 18.2 36.4 AVERAGE VALUES 17.8 35.6 16.8 33.6 16 • t!l 32 • 121 16.2 32.4 AVERAGE VALUES 16.2 16.6 32.4 33.2 79 117 15.8 31.6 82 120 16.4 32.8 DAILY AVERAGE VALUES 86 119 80 116 74 116 77 119 DAILY 8!21 119 77 117 72 116 71 11.8 DAILY 72 118 68 116 64 116 62 117 DAILY 17.2 34.4 16. ~~ 32. 121 1.4. 8 29.6 15.4 30.8 AVERAGE VALUES 16.121 32. 0 15.4 30.8 14.4 28.8 14.2 28.4 AVERAGE VALUES 1.4.4 28.8 13.6 27.2 12.8 25.6 12.4 24.8 AVERAGE VALUES STAGE IN. ===== 26. QIQI 26. !!10 25. 6~:1 24. 8(21 24. l!l!ll 24. 81<!1 24.80 26. 41ll 27. 6!!1 33.60 36. 4121 31.00 35.60 33. 61!1 32. 0V.I 32. 4121 33. 4V.i 32. 4f2l 33. 2(.4 31. 6121 32.80 32. 5121 34. 412f 32. 421121 29.60 3!21. 81!1 31.70 32. l21Y.I 3!21. 8!21 28.8121 28.40 31!1. I21Y.I 28. 812! 27. 2!!1 25.61?.1 24. 8!!i 26. 6!21 DISCHG CFS ====== TEI"'F' DEG C ===== 9 c· .'-! 9.5 9.0 8.5 8.5 9. IZI 8.8 8.5 8.1!.1 8. !21 9.5 8 C' a..J 9. IZI 8.5 8.5 9. :5 8.9 9. Qi 8.5 8.5 1J!I.J..!i 9. !f.i 9.5 8. !21 8. ~:!i 9.5 8.8 9.5 8.5 8. !21 9. !!I 8.8 9.0 8. Qi 8.0 8.5 8.4 RLH~KA ~UW~H RUIHUHl!Y I~M~/~IRb~ ~IUUl~~ DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER r-·aqe 2 Ql2-lo9-B~ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1•<DEPTH+G0)AG2 GIZ!= 1~1 DATE TIME ·---·----------·------------- !218/ 14/86 (~1121: 121!!1 1218/14/86 !216: IZH!l ~::18/ 14/86 12: 121!21 !218/ 14/86 18: Y.ll!! 1218/15/86 121121: !21121 08/15/86 06: Q!Qi 1!18/ 15/86 12: lll!21 1!18/ 1.5/86 18: (40 1!.18/ 16/86 fc:Hil: 0£1 1218/16/86 1Zl6: Y.H!i 1!18/ 16/86 12: ~!!Qi 1218/ 16/86 18: 1!>121 1Zi8 / 1 7 /86 l2li!i: 121121 1!18/ l. 7/86 1!16: 01!1 08/17/86 12: 01!1 1!18/ 17/86 18: 00 Qi8 / 18 I 86 Q!QI: t-::11!1 1!18/18/86 l2l6:Qll21 08/18/86 l.2: 1!1121 1!18/ 18/86 18: 0!2! 08/1 9 I 86 0QS: I!IIZI 1!18/19 /86 1216: Ql0 1!18/19/86 12:1Zll!l Y-18/1.9/86 18:0QJ QI8/21Zl/86 00: 0!!.1 1!18 /20 I 8 6 1!16 : 121121 Q!8 / 2Y.i I 86 1 2 : 0!21 l!l8/2iil/86 18: l!illl IZ18 /21 /86 1211!1: 1!11!1 Qi8 / 21 I 86 l!i6: (~ll!i !i.i8/21 /86 12: !21!21 S!i8/21 /86 18: ll.IS!l BYTE 59 61 63 65 73 75 77 79 81 83 8!:3 87 89 91 93 95 97 RAW DATA MV DEPTH INCHES ========== ====== 62 118 59 115 12.4 11.8 24.8 23.6 56 115 11.2 22.4 56 118 11.2 22.4 DAILY AVERAGE VALUES 57 118 56 116 58 116 56 117 DAILY 59 118 57 116 54 115 11.4 22.8 11.2 22.4 11.6 23.2 11.2 22.4 AVERAGE VALUES 11.8 11.4 110.8 23.6 22.8 21.6 55 121 11.0 22.0 DAILY AVERAGE VALUES 64 121 12.8 25.6 59 115 11.8 23.6 55 114 11.0 22.0 55 120 11.0 22.0 DAILY AVERAGE VALUES 59 122 57 118 54 117 57 118 DAILY 11.8 23.6 11.4 22.8 Hl.8 21.6 11.4 22.8 AVERAGE VALUES 99 58 118 11.6 23.2 101 54 117 10.8 21.6 103 51 117 10.2 20.4 105 53 121 10.6 21.2 DAILY AVERAGE VALUES 107 57 120 11.4 22.8 109 53 117 10.6 21.2 111 51 116 10.2 20.4 113 52 121 10.4 20.8 DAILY AVERAGE VALUES 115 60 122 12.0 24.0 117 55 117 11.0 22.0 119 52 115 10.4 20.8 121 52 121 10.4 20.8 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12:20 G1 = IZ! STAGE IN. ---------- 24. 81.Zl 23. 6!2! 22. 4121 22. 4!!1 23. 3Y.J 22. BIZ! 22.40 23.20 22.40 22. 7121 23. 61!1 22. 8!!1 21. 6!0 22. Ill!!! 22. 51!1 25.6121 23.60 22. 1!1121 22.00 23. 3!!1 23.60 22.80 21.60 22. 8121 22.70 23. 21.!1 21. 61!1 2121. 41ll 21.20 21.60 22.80 21. 2!21 2~.1. 4l!l 21!!. Bill 21. 3l!l 24. fZII!I 22. 1211!1 2!ZI. 8!!1 2121. Btl! 21 • 9!!1 G2= l!l DISCHG CFS ------------ I! I 0 lil Ql Y.l I! I lll 1!1 Ql Ql TEl"'F' DEG C ===== 9. Ill 7.5 7.5 9. !Zl 8.3 9. ill 8. e1 8. Y.i 8.5 8.4 9. I!! 8. !!l 7.5 l!ZI. 5 8.8 1!21.5 7.5 7. 121 HI. !!I 8.8 11. !21 9. l?i 8.5 9. IZl 9.4 9. 1!1 8.5 8.5 1 (!!. 5 9. 1 1121. Ql 8.5 8. IZl 9 ":!' II '-' 8.5 7.5 Hi. 5 9.4 HLH~~H ruw~n HUIMUn~l I tt::.t'lr/wiHI.:lt:;. wiUUJ.t::.o DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER t-'a.ge . .:\ !212-1219-8~ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*<DEPTH+G0>AG2 GQl= ~:l Df.HE TIME -----·-----------===== !!18/22/86 Y.ll!.l: 1210 i!lS/22/86 IZ16: !2>0 1118/22/86 12: Q!Q! i218/22/86 18: l!ll!l I!SE!/23/86 !210: 1210 1218/23/86 1216:00 1218/23/86 12: l!IIZI !218/23/86 18: 121r21 08/24/86 1!10: QIY.I i218 /2 4 I 86 Ql6: QH!I 1218/24/86 12: l!IQI 1!18/24/86 18: IZ10 1!18/25/86 (!10: (210 1218/25/86 !!16: 00 i£18/25/86 12: f21i!l !218/25/86 18: !Zit!l 1-!18/26/86 0121: 1Zit21 1!18/26/86 IZ16: l!lf21 1!18/26/86 12:!210 QiS/26/86 18: f!l!!l i2i8/27 /86 Ql!~: t!ll!l 08/27/86 06:00 Q!S/27 /86 12: £210 1!18/27 /86 18: 0Y.I 1218/28 / 86 ~~!Ill: 0!!1 1218/28/86 1216: 1!111!1 1?.18/28/86 12:100 !ZI8 /28/86 18: 1!1!21 !'.18/29 /86 1211!5: 1!1121 ~!!8/29 /86 1!16: Y.IIZI 1!18/29 /86 12: Y.l!ZI /.-!18/29/86 18:00 BYTE 123 125 127 129 133 135 137 RAW DATA MV ========== ==== DEPTH INCHES ------------ 64 122 12.8 25.6 59 119 11.8 23.6 61 119 12.2 24.4 69 120 13.8 27.6 DAILY AVERAGE VALUES 69 121!1 66 118 63 118 74 119 DAILY 13.8 27.6 13.2 26.4 12.6 25.2 14.8 29.6 AVERAGE VALUES 139 72 118 14.4 28.8 141 70 118 14.0 28.0 143 71 118 14.2 28.4 145 71 121 14.2 28.4 147 149 151 153 155 157 159 161 163 165 167 169 171 173 1 71::: • I ..J 177 179 181 183 185 DAILY AVERAGE VALUES 75 121 78 119 78 118 77 11.9 DAILY 80 11.8 95 118 118 l18 119 119 DAILY 119 118 121 118 115 117 118 118 DAILY 115 118 11219 116 Hl2 116 1Y.I1 12fll DAILY 99 119 93 116 89 116 87 118 DAILY 1 5. 0 31!1. 121 15.6 31.2 15.6 31.2 15. 4 31!1. 8 AVERAGE VALUES 16. V.! 32. 1!1 1 9. l!l 38 ~ !!l 23.6 47 .. 2 23.8 47.6 AVERAGE VALUES 23.8 24.2 23. 121 47.6 48.4 46. j:ll 23.6 47.2 AVERAGE VALUES 23. 121 21.8 2121. 4 46.0 43.6 41!1. 8 21!1. 2 41ZJ. 4 AVERAGE VALUES 19.8 18.6 39.6 -=!I ,., ._, / . "'" 17.8 35.6 17.4 34.8 AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12: 2!Zi G1= 0 STAGE IN. ===== 25. 6$!1 23. 6121 24. 4111 27. 6121 25.3121 27. 61!1 26.40 25.20 29.60 27. 2!21 28.8121 28.1210 28.40 28.40 28.40 30.1210 31.20 31. 2!21 3121. 8$11 3121. 8121 32. 121!!1 38. 1211!1 47. 21!1 4 7. 61!1 41.2121 47.6!21 48. 4121 46. V.ll!l 47.2121 47. 3QI 46.00 43. 6121 40.8121 41!1. 4121 42. 71!1 39.6121 37. 2(3 35. 6'2i 34. 8!ZI 36. 8121 G2= !!I DISCHG CFS ====== 0 0 Ql I! I Ill 121 0 IZI 111 0 0 !21 0 I! I 0 TEr1F' DEG C ---------- 1 L 121 9.5 9. C" • ..J 1121. 121 l. 0. IZI !Ql. IZI 9. 121 9. 121 9.5 9.4 9.0 9.0 9. IZl 1121. 5 9.4 Hl.5 9. 121 9.5 9.6 9. 121 9. 1!1 9. 121 9.5 9. 1 9.1Zi 9. V.l 8.5 9.0 8.9 9. ~~~ 8. 12i 8. IZI liZi. IZ! 8.8 9.5 8. Q! s.w 9. 121 8.6 ALASKA PUW~H AUIHUkliY I~MP/biRb~ biUUl~~ DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER Fage 4 !212-1219-8/ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*(DEPTH+G0)AG2 80= 0 DATE TIME -----------------·--------- 1218/3!!1/86 !ll0: 1!10 1!18/31!1/86 1216: 01!1 1218/3!!1/86 12:100 !218/3QJ/86 18: 1!1121 \218/31/86 !ZI!21:0QI ~~18/31/86 06:fZH!I WBI 31 186 12: 1211!1 Y.IB/31186 18:0121 !il9/!!! 1 I 86 0k1: J.!ll!l !!19/121 1 I 86 1216: 1!1!21 J;.19 /l:H l 86 12 ~ 0121 i!l9 I Qi 1 I 86 18: 121121 !!1911212/86 0!!1: !!1!21 1219 I 1212 I 86 iZ16: QIQI i2!9 /!!12/86 12: Y.IQI J!l91Q12/86 18:00 1219 / !{.13 /86 0~3: ~~i0 !;:1911213186 1!16: IZlfZI !(.19 103/86 12: 0!!.1 i21911!13/86 18: 1!11!1 Y.I9/1Zl4/B6 v.s1o: ello k?9/!Zl4/86 06: 0Y.J 1!1911!14186 12: 01!1 !.!19104/86 18:0121 !Z19 /1215/ 86 1Zl0: 0!!1 !219/iZI5/86 1216: IZIQI 1!19 / ~215/ 86 12: 1!1!!1 !!19 /Y.l~i/86 18: 121121 IZ!9 19.16/86 i!llcl: !!1!21 09 h.!l6/86 1!16: i~l{(.l f2i9N!6/86 12: !!H!I !219/1216/86 18:121121 BYTE 187 189 191 193 195 197 199 21211 203 205 2Ql7 21!19 211 213 215 217 219 221 223 225 227 229 231 2:33 237 239 241 243 245 247 249 RAW DATA MV DEPTH INCHES ========== ===== ====== 9!21 l. 18 87 116 82 116 82 118 DAILY 91 118 96 117 93 116 95 118 DAILY 89 11.7 82 116 77 114 76 119 DAILY 78 119 76 117 72 116 71 11.9 DAILY 71 119 69 117 67 117 68 119 DAILY 18. 0 36. 1!1 17.4 34.8 16.4 32.8 16.4 32.8 AVERAGE VALUES 18.2 36.4 19.2 38.4 18.6 37.2 19 .1!1 38.0 AVERAGE VALUES 17.8 35.6 16.4 32.8 15.4 30.8 15.2 30.4 AVERAGE VALUES 15.6 31.2 15.2 30.4 14.4 28.8 14.2 28.4 AVERAGE VALUES 14.2 28.4 13.8 27,6 13.4 26.8 13.6 27.2 AVERAGE VALUES 71 119 14.2 28.4 67 115 13.4 26.8 63 115 12.6 25.2 62 119 12.4 24.8 DAILY AVERAGE VALUES 65 119 64 115 60 113 58 118 DAILY 64 119 6t~l 115 13.1!1 26.i!l 12.8 25.6 12.0 24. IZI 11.6 23.2 AVERAGE VALUES 12.8 12. Ql 25.6 24.0 57 115 11.4 22.8 55 118 11.0 22.0 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12:2!!1 81= 0 STAGE IN. ---------- :"56. !21121 :::A. 8121 :;:;2. Sill 32. 81!1 34.10 36. 4~1 38.40 37. 212l 38. 01!1 37.5121 35. 6121 32. 81!1 30.81!1 30. 4121 32.4QI 31. 2Y.I 30.40 28.80 28. 4f2S 29.7121 28. 4!.!1 27. 61ZS 26.80 27. 21Z! 27.50 28.40 26. 812! 25.20 24. Btl! 26. 3121 26. 01ZI 25. 6121 24. IZIQI 23" 2f2J 24. 71!> 25. 6121 24.0121 22. 8!Zl 22. 0Ql 23. 6QS 82= 1!1 DISCHG CFS ------------ 0 0 I! I V.J Qi TEriP DEG C ---------- 9. !Zl 8. ill 8. i!l 9. IZI 8.5 9. 'ZI 8.5 8. Ql 9.0 8.6 8 <:" o....J 8.m 7. !2! 9. :::; 8.3 9.5 8.5 8. 1~1 9.5 8.9 9.5 8.5 8.5 9.5 9. Ql 9.5 7.5 7.5 9.5 8.5 9.5 7.5 6 o:::· • ....J 8. 1 7.5 7.5 H~HQ~H ruwtn HWtnunLI r I .:::.rtr I Q I HUt:-. Q I UU L Cu DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER r-·age ;:s ~!12-!2!9-8: BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 DATE TIME ---------------- f!l9 /!(17 /86 !21~1: 11.1~;:1 C39/i2f7 /8o 1!16: f!H?l ~~!9/!?.i7 /86 12:00 !(19/!!17/86 18: IMi !!.19 / !ZI8 I 86 !!10: 121121 1219/08/86 1!16: 00 1!19 /!!18/86 12: 0121 1219/1218/86 18:01!1 (!.19 / !!19 /86 01!1: 0Jil !!19 I !Zl9 I 86 !216: !!1121 i!i9/QI9/86 12:1!11!1 1219/~!19/86 18:121f£1 09/11!1/86 IZ!Ill: 1!1!21 1!19/1121 /86 V.!6; 1!10 1!19 /1 iZi/86 12: 0!21 !!19 /1121/86 18: 00 1219 I 11/86 l!h!l: t!li!i l!i9 / 11 /86 1!16: 1!1!21 1219/11/86 12:0121 !!19/il/86 1e:ult!l Qi9 I 12/86 !21!!1: !!1121 Ql9/12/86 !!16:0121 12!9/12 /86 12: Y.lf21 l!i9 I 12/86 18: I!@ !!19./ 13/86 !!H~: 121121 1!19/1.3/86 1216: fiiel !2i9/ 13/86 1.2: 0!21 ~19 / 1 ::::;86 18: !!1121 i219 /1 4 / 8 6 121121 : CZII!I Qi9 /14/86 1?.16: 12!!21 1219/ 14/86 12: !Ml iZ19/14/86 18:00 BYTE 251 253 255 257 259 261 263 267 269 271 273 275 277 279 281 283 285 287 289 291 293 295 297 RAW DATA MV DEPTH INCHES ----------====== ---------- ~58 118 6£!1 117 64 l.17 65 118 DAILY 1l.6 23.::: 12.1!1 24.1!1 12.8 25.6 13. Ql 26. Qi AVERAGE VALUES 95 118 19.0 38.0 91 117 18.2 36.4 84 116 16.8 33.6 81 115 16.2 32.4 DAILY AVERAGE VALUES 83 115 16.6 33.2 76 114 15.2 30.4 71 113 14.2 28.4 68 117 13.6 27.2 DAILY AVERAGE VALUES 68 117 65 113 13.6 13" .• V.l 27.2 26. J-!1 62 112 12.4 24.8 60 117 12.0 24.0 DAILY AVERAGE VALUES 63 119 6V.l 115 58 114 57 118 DAILY 60 119 57 116 55 114 54 11.8 DAILY 12.6 25.2 12. "' 24! 1!1 11.6 23.2 11.4 22.8 AVERAGE VALUES 12. Q! 24. !21 11.4 22.8 11 • V.l 22 • 121 1.121.8 21.6 AVERAGE VALUES 299 60 120 12.0 24.0 301 56 116 11.2 22.4 303 54 115 10.8 21.6 305 53 118 10.6 21.2 DAILY AVERAGE VALUES 307 56 119 11.2 22.4 309 55 115 11.0 22.0 311 52 113 10.4 20.8 313 51 118 10.2 20.4 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12:2121 61= !Zi STAGE IN. ----------- 24. 1!10 25.60 26. !211!1 24. 7121 38. !21!21 36.40 33.60 32.40 35. HI 33. 2i2i 3121. 4121 28. 4!21 27.2121 29. 8!21 27. 2121 26. f211ll 24.80 24. 0!21 25.5121 25. 2fl! 24. 1!1!21 23. 2I!j 22.8121 23. 8V.l 24. IlliZI 22. 81!1 22.0121 21. 61Zi 22. 61!1 24. ~:1121 22. 4f21 21. 6Q! 21. 2!!i 22. ~:l!i 22. 41!1 22.1!11Zi 21!i. 8121 2121. 41!1 21. 41ZI G2= 121 DISCHG CFS ------------· 121 TEMP DEG C ===== 9. !Zl 8.5 8.5 9.0 8.8 9. 121 8.5 8. 1!1 7.5 8.3 7.5 7. Q! •. <= 0. -.J 8.5 7.4 8.5 6.5 8.5 7.4 9.5 7 r: I • -~ 7.QI 9. 1!1 8. :;:; 9.5 8. 121 9. IZ! 8.4 H.? • ~~~ 8.Ql 7. ::; 9. 121 8.6 9.5 7 C' I • '-' 6 c::· • ...J HI_H:::;,t~.H r UWt:.K HU I HUK l I Y I t:.l'lt'"/ ::J I Hl:!t.:. 0 I UI.J J. t:.b DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER r·age o 1!12-09-8" BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE~DEPTH+G0 DISCHG=G1*<DEPTH+G0)AG2 DATE TII"IE ---------- I!.Fil 1 5/86 Y.JI!.I: 00 i!l9 / 15/86 1Zl6: f!il!l 1219/15/86 12:Y.lel !?!9/15186 18:1!11!1 1Zl9 / 16/8 6 IZHZl: f21lZl iZl9 / 16/86 06: 0~1 il.l9/16/86 12~>::i!f"i >:>·, l :;_,::;.' ·:!6 ; 2: ~Ml e'tr..t / 1 (:; / sc .. \ 1 c:1 ~ ;~)(·) t. i:·_' ' . ' .. ' :.· ~-) ~ : ;: -: .:.o l ~2: l!lQl 09/2~!186 18: J?ll!l !!l9 / 21/86 ~~~~;l: Y.l0 1~19 /21 /86 !~16: I!HZl !ll9/21 186 12: f!l0 12l9 / 2 1 /86 18: llH!l i2l9 I 22 I 86 !!ll!l: !llt!l t1.l9/22/86 Ql6: l!l!~i li.l9/22/86 12: 01!.1 !!.!9/22/86 18: QIQ.i BYTE 315 317 319 321 323 -:t ·-. ·~ ..:.•...:..• .. ' --_,., ~-~..:.... I RAW DATA ========== 57 120 55 117 54 1.17 62 119 MV 11.4 11. IZi 11!5.8 12.4 DEPTH INCHES ====== 22.8 22. !!l 21.6 2'.-. 8 DAILY AVERhGE v! ''-· ._;i.S 7!!1 121!1 / 0 l J. ~~ di:,l ~ 1-1 .i. 6. l{i :.J. 2 :3;;;;:. Qj 329 80 li~ 16.0 32.0 ~:· ·:: ·I ......... 1 .t -· -:~~-._ ......... ,, 335 337 DAlLY AVERAGE VALUES 80 119 16.0 32.0 72 118 14.4 28.8 75 119 15.0 30.0 73 119 14.0 29.2 Dt'-) ll.Y AVERAGE VALUES 359 71 118 341 66 11.5 342~ 61 1:14 1i.i.2 12.2 26.4 24 •. q 3~5 60 118 12.0 24.0 DAILY AVERAGE VA~UES :~~;i. ~?· ~,~; l18 .. :.4~· ~-··~8 1 1 ~:J .,~.· .• .:,. " .c:- ,. ,·; . ·"··flJ.; ... •. •·. ''.,,' 357 363 365 367 369 371 373 375 37'7 ...... I .i i. ' '' ~ J, • ,. •;,• 22. Qj L.~ AVERAGE VALUES c~:;:~ li8 78 119 86 118 77 120 DAILY 75 118 71 117 69 116 68 118 DAILY 67 118 64 115 I 12.4 24.8 15.6 31.2 17.2 34.4 15.4 30.8 AVERAGE VALUES 15.0 14.2 30. f(J 28.4 13.8 27.6 13.6 27.2 AVERAGE VALUES 13.4 12.8 26.8 25.6 60 115 12.0 24.0 69 116 13.8 27.6 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08106/86 18:00 STOP: 11/19/86 12:20 Gl= f!! STAGE IN. ---------- 22. 8121 22. iGII!l 21. 6\!i 2;::::_,. Qj~Zl :3::::. ~~11!1 :3,!!. SQ: :32. IZII!I ::;~5. Bib :::r~,. k~i~: 2t?l. :·;~~~) ~)Qi. li)~{; 28. cl-(}1 26" 4121 24 • .~.:.w . . . .... '·r '· .· .-:·; ........ : :; 22. lZl!ZI 22.8121 24.80 31. 2!21 34. 41!1 31!1. 80 3121. 3!!1 30 .lliV-1 28. 41!1 27. 6£1 27. 21Zl 28. 3Y.l 26.80 25. 6121 24. 1!11!1 27.60 26. I!H!l 82= 0 DISCHG CFS ====== !·! 0 0 !!I 0 0 TEMP DEG C ---------- ·-' & - w • ....;· & ._• ;. •j J, ):..~ • •• ·-~ # "' ... I • -· 7.: 8.5 8 .. 9.0 9.5 9.f 1Ql. 2 9,.!.. 9. ;.' s.:: 8.::: 9. ,:: 7.: I I < ~ 8 .... ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 7 !212-!i.l9-8: BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*<DEPTH+G0JAG2 60:::: Ql DATE TIME -·--------- ~:s 9 12 3/8 6 l!i!Zi : i2H!.l 1!!9/23/86 !216: ~ZliZJ 1219/23/86 12:100 1!19/2::'186 18: l!l!ll !219 /24/86 fliQI: V.!IZ! !!.19/24/86 06: 01!J 1!19 /24/86 12: IZIIZI ~99/24/86 18:1ZHEI !!.l9 /25/86 ~!ll!l: 00 iZ19 I 25/86 1Zi6: I!IIZI !219/25/86 12:0121 1219/25/86 18: IZI!Zl 1!19 i 26 I 86 1210: 1!11!1 Q/9 /26/86 1?.16: 1!10 1219/26/86 12: QIQl ~19/26/86 18: 01!1 1Zl9/27 /E16 l!l~!i: !210 Ql9/27 /86 i!16: QIQI 1219/27/86 12:011J ll19 /27/86 18: IZI!!J 09/28/86 1!!1!1: fl!f21 Q19 I 28/86 !216: 010 1!19 /28/86 12: Y.IIZI (il9 128/86 18: ~il0 QS9 /29/86 1M.:1: !210 !!19/29/86 I216:1ZIIZI 1!19 / ;!·:f /86 12: JZI~~~ ~jCjl /29/86 18! l!iQI !Zl'l / :;;IZl I 86 1210: 1211!1 C.:i'?'/3~~~/86 06: 0!Zi !ZI9/3!Zl/86 12: !MI ~219/3W.U86 18: Y.HIS BYTE 379 ::;;a 1 385 389 391 393 395 397 399 41!11 41!13 405 41!17 409 RAW DATA MV DEPTH INCHES ========== ==== ____ ,. __ ------ 72 114 67 112 14.4 13.4 28.8 26.8 61 111 12.2 24.4 60 112 12.0 24.0 DAILY AVERAGE VALUES 59 112 58 11!19 55 108 54 111 DAILY 53 112 53 11!19 49 1f.l7 52 109 DAILY 51!1 11 1!1 49 108 49 109 47 111 DAILY 11.8 23.6 11.6 23.2 11. 0 22. 1!1 10.8 21.6 AVERAGE VALUES 1J!i.6 21.2 10.6 21.2 9.8 19.6 10.4 20.8 AVERAGE VALUES HI. Ill 21!1. 1!1 9.8 19.6 9.8 19.6 9.4 18.8 AVERAGE VALUES 411 49 113 9.8 19.6 413 48 113 9.6 19~2 415 47 113 9.4 18.8 417 46 115 9.2 18.4 419 421 423 425 4·27 429 431 433 435 437 439 441 DAILY AVERAGE VALUES 47 116 46 115 45 114 45 1.17 DAILY 44 118 45 117 46 116 46 118 DAILY 48 118 49 117 49 116 48 11.7 DAILY 9.4 18.8 9.2 18.4 9.~1 18.1!1 9.121 18.121 AVERAGE VALUES 8.8 17.6 9 • 1!5 1 8 • 1!1 9.2 18.4 9.2 18.4 AVERAGE VALUES 9.6 19.2 9.8 19.6 9.8 19.6 9.6 19.2 AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12:20 61:::: !?i STAGE IN. ----------- 28. 81!1 26. 8!?1 24.40 24. 1Zil2i 26. l!fl!l 23. 6!21 23. 2f2i 22. 1!10 21.60 22.60 21. 21:? 21. 21!l 19.60 20. 81!1 21!1. 70 21!1. 1210 19. 61!1 19. 6121 18.81!1 19.50 19.60 19. 2121 18. 8!!1 18.40 19. 0121 18. 8121 18.40 18.1!@ 18. Q.lfll 18. 31!1 17.60 18. QI!ZI 18. 41.11 18. 41!1 1.8. 1(1 19.20 19. 610 19. 6121 l. 9. 2121 19. 41!1 G2= 0 DISCHG CFS -----·------- (1 0 TEI'1P DEG C: ---··--·M ----- 7. ~!I 6. 121 5.5 6. IZl 6. l 6. !!I 4.5 4.0 5.5 5. Q! 4.5 :3.5 4.5 4.6 5.1!1 4.0 4.5 5.5 4.8 6.5 6.5 6.5 7.5 6.8 8. lZ! 7. !21 8. ;:; 7.8 <r. J!j 8.5 8. 121 9. i2i 8.6 9. Ql 8.5 8. l!l 8.5 8.5 ALA~KA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 8 !!S2-!2f9-8~ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*<DEPTH+G0)AG2 G0= 121 DATE TIME MO_, ______ _ --------===== 1 !?.i I 125 1 /86 IZlQI: (!S!2S 1 !21 / !Zl 1 I 86 IZ16: 12SI21 l!Zi/1!11/86 12:00 Hl/!211 186 l8: 1!1121 1!2!/ 121 2 I 8 6 I!H!I : IZI IZI 11!1/02186 06: 1210 11!1/ 1!12 I 86 12: Y.IIZ! 1.1?1 I ~!12 I 86 18: ~;,!I 1121 I IZl ~S I 8 6 12@ : 1!10 li!S / 1!!3 I 86 IZI6: !2S~~I 1.12ihll3/86 12: !!liZ! lQS I 12!3 I 86 18: 1211!1 1!~1 I !ZS 4 I 8 6 1!1 1!1 : !!I 121 H.?IIZI4186 !!S6: ~j0 1 Y.S / !!14 I 86 12: 121121 11!1/ !254/86 18: !2H-3 Hl/05186 l11!ZI: 1!11?! U!l / 1!15/86 QS6: IZI!!I H::S/1!15/86 12: 12!121 l!ZI/!215186 18:121121 Hl./!!16/86 IlliZI: Y.IIZI 11!1/06186 06: QIJ!I 1 !Zl I l!l6 I 86 l. 2 : 1!1121 lfZI/J2l6/86 18: 01!1 l!Zl /1217 I 86 QSQ!: 1!1121 1!21/1217 186 1!16: !21!21 l!ZI/!Z17 186 12:1210 1!2!1!!.17186 18:1Zl!ZI li!l / !!18 /86 IZIIZI: !?SQI 1121/!218/86 !216: ~jiZS HS/!218/86 12: !!11!1 ll!l/1258/86 1.8:0121 BYTE 443 445 447 449 451 453 455 457 459 461 463 465 467 469 471 4 --· I~' 475 477 479 481 483 485 487 489 RAW DATA -------------------- 49 117 48 116 49 1l.6 51!5 117 MV DEF'TH INCHES ------------ 9.8 19.6 9.6 19.2 9.8 19.6 HI. !21 2!?l. !21 DAILY AVERAGE VALUES 51!1 117 50 116 1£!!. !?I 10. Ql 21!1. 1!1 2121. 1!1 50 115 10.0 20.0 49 117 9.8 19.6 DAILY AVERAGE VALUES 51!1 117 51 115 l!ZI. 2 20. v.s 212!. 4 53 115 10.6 21.2 65 115 13.0 26.0 DAILY AVERAGE VALUES 58 113 54 112 11.6 10.8 21.6 52 112 10.4 20.8 51 113 10.2 20.4 DAILY AVERAGE VALUES 51 113 49 11!19 4 7 11217 48 11219 DAILY 11121 108 10.2 20.4 9.8 19.6 9.4 18.8 9.6 19.2 AVERAGE VALUES 9.4 9.2 18.8 18.4 47 46 43 46 107 8.6 17.2 109 9.2 18.4 DAILY AVERAGE VALUES 491 44 112 8.8 17.6 493 43 112 8.6 17.2 495 42 112 8.4 16.8 497 43 114 8.6 17.2 DAILY AVERAGE VALUES 499 41 114 8.2 16.4 501 41 113 8.2 16.4 503 41 111 8.2 16.4 505 40 113 8.0 16.0 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08106186 18:00 STOP: 11119186 12:20 G1= ~~~ STAGE IN. ---------- 19. 61!1 19. 21!1 19. 6!!S 21!1 • l!l 121 19. 6lZl 21!1. 0.1!1 2~!1. 01!1 21!1. !!10 19. 6!!1 19. 9121 2121 • {() 121 2121. 4121 21. 21!1 26. 1!10 21.90 23. 2Qi 21. 61!1 2121. 8121 20. 4·1!1 21. 5!21 20. 4121 19. 61!1 18. 81?.l 19.20 19. 51?1 18.8121 18.40 17. 21!1 18.40 18.2121 17. 6Ql 17. 21ZI 16.80 17. 2!!1 17. 21!1 16.40 16.4m 16. 41!1 16. l!ii!l 16. 3121 G2= 121 DISCHG CFS ------------ Q'l Q! IZI 0 IZS I! I IZl Ql Ql 121 Ill IZI 0 0 Ill TE:MP DEG C ---·-----·-- 8.5 8. Qi 8. Qj 8.5 8.3 8.5 8. Qj I c:- 1 • ..J 8. ::i 8. 1 8 <:', . ,_, 7.5 -r e- / • ....J 7.5 7. El 6.5 6. i!l 6.0 6.5 .. ~ o. ~·· 6.5 4.5 4.5 4.8 4. !!5 4.5 4.3 6. !Z! 6. IZ! 6. ~1 7. Qj 6.3 <= C' ..Jaw 6.5 6.4 ALASKA POWER AUfHORlTY TEMP/STAGE SlUDIES DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER Page 9 t2!2-IZ19-8-: BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 DATE TIME ----------·---------------- 1121 / 121 9 /8 6 121 121 : l!l I!! Hi/ 1219 /8 6 Ql 6 : £!11!1 U!i/12!9/86 12: !Zii!l 1 Ql/1!.19 /86 18: l!l!ZJ 1121/11!1 /86 121121: 1!112! Hl/ 10/86 1!16: 121121 Hi /l!Zl I 86 12 : IZlQ! 11!1/11!1/86 18:00 U!l / 11 /86 l!li!l: Qlf21 li!l /11/86 1216: IZJI2l 11!1/11/86 12:1211!1 11!1/ 11/86 18: IZl!Zl Hi / 1 2 / 8 6 IZl!Zl : IZli!J U!l/ 12/86 1!.16: 1!10 HI/ 12/86 12: IZll!l U!l/12/86 1.8:0121 1 Q! / 1 3 / 86 1!11!1: 012l 1121/13/86 IZ16: i2!12! 11!1/ l.:3;/86 12: IZliZl Hi/ 1 3 I 86 18 : 121!21 Hl/ 1 4 / 8 6 Q! 12! : l!l!!l l. 0114/86 1216: l!l!!l HI/ 14/86 12: Q!IZ! liZ!/ 14/86 18: '1!ll UZI I 15/86 01!1: 1!1~3 1 iil / 1 ::; I 86 1216: 1!1121 1Ql/l.5/86 12:v.J!Zi U?.!/15/86 18:1!1!21 1 !!.1 I 16186 !:"%!: 1!1121 Hi/ 16/86 !!16: 1!1!21 HI/ 16/86 12: I.!I!Z! l.!!l/ l.6/86 18: ~21!!1 BYTE 51217 5i!l9 511 51:;;; 515 517 519 521 523 C"'• ..... l:' ....J..::....J 527 529 531 535 537 RAW DAT{~ MV DEPTH INCHES ========== ------------ 41!1 11:3 41!1 1 11 39 113 56 115 DAILY 134 118 2HI 118 213 118 202 118 DAILY 216 118 21213 117 178 116 154 116 DAILY 138 116 132 115 124 115 131 115 DAILY 8.1!1 16.121 8.1!1 16.121 7.8 15.6 11.2 22.4 AVERAGE VALUES 26.8 42.0 53.6 84.0 42.6 85.2 4121. 4 81!1. 8 AVERAGE VALUES 43.2 41!1. 6 86.4 81.2 35.6 71.2 3121. 8 61. 6 AVERAGE VALUES 27.6 26.4 24.8 26.2 55.2 52.8 49.6 52.4 AVERAGE VALUES 539 186 116 37.2 74.4 541 207 116 41.4 82L8 543 176 115 35.2 70.4 545 151 116 30.2 60.4 547 549 551 553 r:·r:c::- ...J...J...J 557 559 561 563 565 567 569 DAILY AVERAGE VALUES 136 115 126 114 124 113 116 114 DAILY 116 113 114 113 HIS 11:2.~ 11!17 114 DAILY 11Zi7 114 Hi4 112 99 111!1 96 112 DAILY 27.2 54.4 25.2 50.4 24.8 49.6 23.2 46.4 AVERAGE VALUES 22.8 21.6 21.4 46.4 45.6 43.2 42.8 AVERAGE VALUES 21.4 21!1. 8 19.8 42.8 41.6 39.6 19.2 38.4 AVERAGE 'VALUES DATA FILE NFORK04 START: 08/06186 18:00 STOP: 1111-:;:186 12:2!Zi G1= IZi STAGE IN. ---------- 16. 12l1Zl 16. 121121 15. 6QJ 22.4121 17. 51!1 53. 61!1 84. 121121 85. 2121 80.80 75. 91!1 86. 4f1J 81. 212! 71. 21!1 61. 61!1 75. 10 55. 21Z! 52. 81ZI 49. 61!1 52. 41!1 52. 51Zl 74. 41~1 82. 8121 7t9. 4121 61!!. 41!1 72. 0~3 54. 41!1 5Ql. 40 49. 6121 46. 4~;1 5V.!. 2!!1 46.4111 45. 6!21 4:3. 21:!5 42. 8!Zl 44. 5Qi 42. BIZ! 41.. 61-?1 39. 6l..ii 38. 4Ql 41!1. 61!! G2= !Zl DISCHG CFS ------------- Ill J2j 0 0 !Zi TEMP DEG C ---------- 5.5 6.5 6.5 9.0 9.0 9.0 9. (~ 9.0 9. ~) 8.5 8. ~; 8.0 8.4 8.0 7.5 7.5 '7 .:::: I o ,_, 7.6 8. ~-;; 8. i2: 7.5 8. i~ 7.9 7.5 7.0 6.5 7. fi 7. ~) 6.5 6. ~~ 6.5 7 .• :j 6.b 6.0 5.12! 6. Q'. 6. Q; ALASKA POWER AUTHORlfY fEM~/~IAb~ ~IUUl~~ DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER ~a<Je l!Zl 1!12-1219-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*CDEPTH+G0)AG2 Gl21= 121 DATE TIME ======== ---------- Hi/ 1. 7/86 !!lQI: ~!l~ii l!ii/ 17/86 !!16: 1!112! HI/ 1 7/ 86 12: !~0 li2!1 17/86 18: Qllli Hi/ 1 8 I 8 6 Ql!!l : 1!1121 1121/ 18 I 86 1!16: lZI!!i 11!.11 18/86 12:121121 Hl/18/86 18:k.?fZI 1121/19/86 !21!2l:0~!i 1!2!/ 19/86 !2i6: 121121 ll!l/]. 9/86 12:0121 l. Qi I 1 9/ 86 18: 121121 U!l I 2121 / 8 6 121121 : 121!!1 1!21/21!5/86 1216: 1211!1 1121/2121186 12: llll21 1QI/2~?il86 18:100 1121/21 / 86 l!i!Zl: !Zl!Zl ll!l/21/86 1216: 121121 Hi/ 21/86 12: (!1121 11!1/21 /86 18: l!il!i hi/22/86 l2li!l: l!il!l 1QI/22/86 1216: l!l0 11.!1/22/86 12: 1!1121 Hl/22/86 18: 01Zl 1Ql/23/86 1!11!1: 1!10 1121/23/86 1!16: 1!1121 Hl/23/86 12: 1211!.! Hi I 2:::/86 18: 1!11!1 Hi I 2 4 / 8 6 121121 : 121121 11!1/24/86 1216: l!lJ!i Hl/24186 12: 1!1121 1121/24/86 18:1210 BYTE 571 573 575 577 RAW DATA -------------------- 91 111 88 11!19 83 1!?.19 84 111 MV DEPTH INCHES ------------ 18.2 :>6. 4 17.6 35.2 16.6 33.2 16.8 33.6 DAILY AVERAGE VALUES 579 81!1 111 16. 121 15.4 14.8 32.l!J 30.8 29.6 581 77 1:1.1 583 74 111 585 73 112 14.6 29.2 587 589 591 593 595 597 599 601 603 61215 61217 61!19 611 613 615 617 619 621 623 , ,.,c· o..::.~J 627 629 6:::1 633 DAILY AVERAGE VALUES 112 1 1 1 111 14.121 13.6 13.4 28.0 27.2 26.8 7121 68 67 66 110 13.2 26.4 DAILY AVERAGE VALUES 64 111!1 63 111!1 62 111 12.8 12.6 12.4 25.6 25.2 24.8 60 113 12.0 24.0 DAILY AVERAGE VALUES 62 113 68 113 69 113 75 113 DAILY 74 113 72 113 12.4 24.8 13.6 27 .. 2 13.8 27.6 15. !21 312i. 121 AVERAGE VALUES 14.8 14.4 29.6 28.8 70 113 14.0 28.0 68 113 13.6 27.2 DAILY AVERAGE VALUES 67 112 66 111!1 64 11!!9 13.4 13.2 12.8 26.8 26.4 25.6 63 110 12.6 25.2 DAILY AVERAGE VALUES 61 111 12.2 24.4 59 109 11.8 23.6 58 108 11.6 23.2 57 109 11.4 22.8 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08106/86 18:00 STOP: 11/19/86 12:2~1 G1= 121 STAGE IN. ---------- 36. 4121 35. 2i!j 33. 2t?i 33. 61Zi :34. 61!.1 32. I!IIZI 30. 8121 29. 6!21 29.2121 3121. 4121 28. l!h!l 27. 2121 26.80 26. 41ZI 27. 1i2l 25. 6!21 25.20 24. 8!21 24.00 24. 9fli 24. BIZ! 27. 2121 27. 61!i 31!1. l!iiZI 27. 4(? 29. 61.!1 28.8121 28. 121121 27.20 28. 4121 26.80 26.40 25.60 25. 21ZI 26. 125121 24. 4i!i 23. 2!21 22. s,~s 23. 5Qj G2= 12> DISCHG CFS ___ .. ___ _ ------ 0 ill 121 121 12! TEI"iF' DEG C ====:::.: e c: _,. lo...i 4.5 4 1:' . .._) I::"" c:· .__1 • ._.1 5. QJ 6. 121 5. !11 6 C::' . .._) 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6. :=; 6.5 6.5 6. 121 4.5 5.0 5. 1 4.1:i 4.5 4.6 ALASKA ~UW~k AUfHURliY I~M~/biHb~ SIUUl~o DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER !'"'age 11 1212-1219-8: BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl*CDEPTH+G0)AG2 Gi2i= ~!I Df.HE TIME -----------------===== Hi/25186 IMI: QH!I 1!21/25/86 1!.16: l?h21 l!Zl/25/86 12: 01!1 l$21125/86 18: 1211!1 1 i21 I 26/86 Ill!!!: !!IQ! Hl/26186 1!16: 00 Hl/26/86 12: 1!11!1 H:J/26/86 18: I!H!I Hi/~27 /86 ~:!1121: {(.10 11!1 I 2 7/86 1!16: 121121 Hl/27 /86 12: Y.IQI lll!/27 I 86 18: QIQI 1 1!1 /28186 V.l!!l: !21!21 1121/28/86 1f.j6: !?.10 Hl/28/86 12: V.lf!l 1121/28186 18:1210 Hi/29/86 1!.1121: 0lli 1!21/29186 !216:!21121 U!l/ 29/86 12: 1210 1121129/86 18: l!ll!l 1 iZI /31!1/86 1!1!!>: ~!11!1 1121/30/86 !!16: 00 11!1 /31!1/86 12: 0!21 10/3121/86 18:0121 11!1 /31/86 l!l~j: 00 11!1 /3 1 I 86 1216 : l!l!!l 1.1Ji/31/86 12:!?Ji21 Hi I 3 i I 86 18: l!ll!i 11 I 1!11/86 121121: I!SI!l 11/V.I 1/86 Q16: 1!10 11 I~~~ 1 /86 12: !111!1 11 / 1!11 I 86 18: 0~!> BYTE ==== 635 637 639 641 643 645 647 649 651 653 655 657 RAW DATA 1'1V DEPTH INCHES ---------------------------------- 56 1QI9 55 11!18 54 11217 53 108 DAILY 51 11!18 51 11217 50 11217 5121 108 DAILY 48 11218 47 11216 44 106 47 106 DAILY 11.2 22.4 11 • 121 22. Ill H3.8 21.6 1121. 6 21. 2 AVERAGE WiLUES HI. 2 2121. 4 10.2 20.4 11!1. 0 20.(!1 10.0 21!1. 0 AVERAGE VALUES 9.6 19.2 9.4 18.8 8.8 17.6 9.4 18.8 AVERAGE VALUES 659 45 106 9.0 18.0 661 41 106 8.2 16.4 663 40 106 8.0 16.0 665 45 107 9.0 18.0 667 669 671. 673 675 677 679 681 DAILY AVERAGE VALUES 42 H!l7 38 1QI7 37 106 39 11!17 DAILV 37 106 31!1 106 27 11216 35 106 DAILY 8.4 16.8 7.6 15.2 7.4 14.8 7.8 15.6 AVERAGE VALUES 7.4 14.8 6.0 12.0 5.4 H!l.8 7.121 14.121 AVERAGE VALUES 683 38 106 7.6 15.2 685 33 106 6.6 13.2 687 33 106 6.6 13.2 689 42 106 8.4 16.8 691 693 695 697 DAILY AVERAGE VALUES 43 1 !!iS 43 1.09 46 111 46 113 DAILY 8.6 17.2 8.6 17.2 9.2 18.4 9.2 18.4 AVERAGE VALUES DATA FILE NFORK04 START: 08106186 18:00 STOP: 11/19/86 12:2Qi G 1 = 121 STAGE IN. ---··------- 22. 4121 22. !21121 21 . 61(J 21.2121 21. 8121 2121. 41!1 20.40 21!1. 1!10 20.121121 21!1. 2121 19. 2Ql 18.80 l.7.60 18. 81!1 18.60 18, 1211!1 '16. 41!1 16. 0121 18. 0V.l 17. 1121 16. 81?.1 15.20 14.8121 15. 61!1 15. 6121 14. 8Qi 12.00 Hl.80 14. l!liZl 12. 91!1 15. 2Y.l 13. 21Zl 13 .. 21!1 16. 8121 14. 61Zi 17. 21!1 1 7. 2!21 18. 4\!j 18. 41?.1 17. 8~!1 62= V.i DISCHG CFS ======= 0 0 I! I (1 121 121 0 I! I 0 121 TEMP DEG C -----· ----- 4.5 4. l!i 3.5 4. i21 4·. Qj 4. l2i 4. 1{.1 3.8 4. 121 3. e~ 3. Ql 3.3 3. l2l 3. 1 ..,.. C' ...:i • ...J 3.4 3. 121 3 .!Zi 3. QS 3 .. Qi 3. IZJ 3. Ql 3. l!i 3. 1!1 3. ~~ 4. l!i 4.5 HLH~~H ~WWCh HWIHUh,lY i t:.t•w I :J I Hl:H:: :J l UU .1. c.;:> DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER r·c\ge .t..:.. 1!12-1219-87 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=Gl•<DEPTH+G0>AG2 GQ!= Q! DATE TIME _,.._______ ------·------------ 11 / QJ2 I 86 C!ll~!: !!ll!i 11/i2l2 / 86 106: !!i(!l 11/!1.12/86 12:1!.11!! 11/1212/86 18:12112! 11/1!13/86 1!1121:0~~~ 1l./Q!3186 (.16:!2!12! 11/!!13/86 12: Q!Q! 11/!213/86 18:01!1 11/04/86 l21i2!: 00 11/04186 06: il10 11/ !!14/86 12: J!l~!! 11 I 04 I 86 1 8 : 121121 11/05/86 l2l1ZI: i!i!21 11/1215/86 06:121121 1111215/86 12:!!lV.I 1111!15/86 18:1210. 11/1216186 0121: 01!.1 11 I Y.i6/86 1216 : IZIIZI 11./1216186 12: i21t!f 1 l. /1!16 I 86 18: !!iQi 11 / 1!.17 /86 !211!1: 1211!1 11/1117/86 1216: 0~21 11/07 /86 12: 12H21 11/07/86 18: (1!!1 11/08/86 IZH21: QH!I 11 11!!8/86 !216: !21121 11 /lliS/86 12: !?J0 11/1!18 /86 18 : I!I!ZI l. 1/ !219/86 121121: t!l.lll 11 / 1!19 I 86 1!16: V.I!ZI 11/1!19 /86 12: ~;HZI l. 1. I Ql9 / 86 18: IZ!Y.I BYTE 699 71H 71213 71!15 7Ql7 7!2!9 711 713 715 717 719 721 723 7 '11:' 4..J 727 729 731 733 735 737 739 741 743 745 747 749 751 753 755 757 759 761. R1~W DATA MV DEPTH INCHES ========== ====== 47 1.14 49 114 57 114 68 114 DAILY 6Y.l 113 59 112 9.4 18.8 9.8 19.6 11.4 22.8 13.6 27.2 AVERAGE VALUES 12. 121 11.8 24. 121 23.6 55 112 11.0 22.0 58 112 11.6 23.2 DAILY AVERAGE VALUES 65 113 13.0 26.0 59 112 11.8 23.6 57 112 11.4 22.8 56 112 11.2 22.4 DAILY AVERAGE VALUES 55 112 54 111 11. 1!1 10.8 22.0 21.6 53 111 10.6 21.2 52 111 10.4 20.8 DAILY AVERAGE VALUES 52 111 5121 110 48 109 47 110 DAILY 45 11118 43 11217 43 11217 44 108 DAILY 45 11!19 45 11!21 43 11121 43 11121 DAILY 43 111 4:: 111 10.4 20.8 HI.QI 2!21.121 9.6 19.2 9.4 18.8 AVERAGE VALUES 9.121 18.121 8.6 17.2 8.6 17.2 8.8 17.6 AVERAGE VALUES 9.1!1 18.0 9.!!1 18.121 8.6 17.2 8.6 17.2 AVERAGE VALUES 8.6 8.6 17.2 17.2 51 112 10.2 20.4 49 111 9.8 19.6 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08106/86 18:00 STOP: 11/19186 12:21!1 G1= !!! STAGE IN. ---------- 18.81!1 19. 6QI 2~!. 8"' 27. 2121 22. 1121 24. 1!1121 23. 6Y.l 22. 121121 23.20 23. 21!1 26. 1!1121 23. 6QI 22. Si!i 22.40 23.7121 22. I!IIZI 21.6121 21. 2121 2121.80 21. 4r21 20.80 21!1. !210 19. 21!1 18.8121 19.70 18. 1211!1 17. 2121 17. 2121 17.60 17.50 18. f!lJZI 18. J.!IQI 17.20 17. 212! 17. 6QI 17. 2!21 17. 21?.1 21!1. 41!1 19.60 18. 6QI G2= 121 DISCHG CFS ______ .. ------ 121 0 121 !!I !Zl TEt1F' DEG C -----· ----- 7. Qj 7. IZl 7. ~:1 7. l!i 7. i!i 6.5 6. !!I 6. i!l 6. i~l 6. 1 6.5 6. i!l 6. QJ 6. !ZI 6" 1 6. iZ! .::-c· ~. 'I.J 5.5 5.5 5.6 C' <= t..J •.... J 5. ~!5 4. ::; 5. !21 5. Qi 4. l!l 3.5 ..,. = ·-'. -· 4. !Zi 3.8 4.5 5. Q$ 5. IZi 4.9 5,5 5.5 6. Qi ALASKA POWER AUTHORITY TEMP/STAGE STUDIES DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER Page 13 IZ12-I219-8 BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*CDEPTH+G0)AG2 Gl!!= 12! DATE TIME --·-----------__ .. __ .. ____ ----- 11/ H!/86 Q!Q!: !!liZ! 11/HI/86 (!16:1!1~! 1 1 / 11!! /86 12: !2!0 11 / 1 Q!/86 18: !!liZ! 11/11/86 l!l!!i: IZI!!l 11 / 11/86 !!.16: !!!!!! 1 1/1 1 I 86 1. 2 : !ZI!!I 11 I 11 /86 18: 1211!! 11/12/86 12!1?.1: 1!10 1 1 I 12 / 86 !216 : 121iZ! 1l./12/86 12:121121 i 1/12/86 18: 1!112! 11/13/86 !21&!1: 12!1Zi 11/ i 3/86 1216: 01!1 11 I 1 3/86 12: QIIZ! 11/13/86 1.8:!210 11 / 1-4/86 1211!1: ~~!1!1 11/14/86 1216: 1!10 11/ l.LL'86 12! 00 1 1/14/86 18: 1!1!21 11 / 15/86 iZll!l: 1!1121 11/15/86 V.16!1ZI!Zl 11/15/86 12: IZI!Z! 11 / 15/86 18: IZ!IZ! 11/ 16/86 1!!121: 0i!l 11/ 16/86 IZ!6: 12112! 11 / 16/86 12: Ql~? l.l/16/86 18: l!ll!l 11 / 1 7/86 1!112!: Qil2l 11/17/86 1216: !Z!IZ! 11 / l 7/86 12: !Zll!l 11 / 1 7/86 18: Qll!l BYTE 76~5. 765 767 769 771 773 775 777 779 781 783 785 787 789 791 793 795 797 799 81211 81213 805 81217 81!19 811 813 815 817 liAW DATA MV DEPTH INCHES -------------------------------- 46 112 9.2 18.4 45 112 9.0 18.0 44 112 8.8 17.6 45 113 9.0 18.0 DAILY AVERAGE VALUES 44 112 42 111 42 111 42 111 DAILY 41 112 40 112 39 111 38 111 DAILY 38 1H! :::::7 108 37 108 38 110 DAILY 39 111 38 112 38 112 41!1 113 DAILY 38 112 37 112 37 112 37 112 DAILY 36 111 35 111!1 8.8 17.6 8.4 16.8 8.4 16.8 8.4 16.8 AVERAGE VALUES 8.2 16.4 8.1!! 16.121 7.8 15.6 7.6 15.2 AVERAGE VALUES 7.6 '15.2 7.4 14.8 7.4 14.8 7.6 15.2 AVERAGE VALUES 7.8 15.6 7.6 15.2 7.6 15.2 8.1!1 16.1!! AVERAGE VALUES 7.6 15.2 7.4 14.8 7.4 14.8 7.4 14.8 AVERAGE VALUES 7.2 7. 121 14.4 14. Q! 34 109 6.8 13.6 32 109 6.4 12.8 DAILY AVERAGE VALUES 819 :3121 1 i!17 821 25 Hl6 823 25 11!16 6. 1!1 5. !Z! 5. IZ! 12. 1!1 1121. 1!1 11(!.1!! 825 28 106 5.6 11.2 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12:2Ql G1.= Ql STAGE IN. ---------- 18. 41!! 18.12112! 17. 612! 18. 12!12! 18. 01!1 17. 61!1 16. Bt!l 16. 812! 16.80 17. 1!11!! 16. 4121 16. 1!11!1 15. 6~!5 15. 2121 15.8111 15. 21!1 14.80 14. 81!! 15. 21!1 15. IZIIZ! 15. 612! 15.2121 15.21!1 16. 1211!! 15.51Zl 15. 212! 14. 8121 14.80 14.80 14. 91!! 14.4125 1 4 • IZIIZ! 1. 3. 6Q.I 12. BIZ! 13.712! 12. IZ!IZ! 1121. Q!Q! 11!1 • 12! !2! l. 1.. 21!l lY.!. 81!1 G2= 12i DISCHG CFS ------------ TEMP DEG C ===== 6. !Zi 6. ~~~ 6. fl 6.5 6. 1. 5.5 5.5 5.5 5.6 6. l!l 6. !15 c:' t::' '-!o...J 5.5 5.8 5. !!! 4. Qi 4. 12! 5. !!i 4.5 6. 12~ 6. !21 6.5 6. ~25 6. !ZI 6. 1!1 6. Qi 6.125 5.5 5. Qi 4.5 4.5 4.9 ..,. t::' ._\. ,_) :: .• ~Zi 3. l(l :: .• !21 3. 1 ALA~KA PUWEk AUIHUkliY IEMP/~IAb~ ~IUU!Eb DATA REPORT FOR DATAPOD DP211SG -STAGE AND TEMP. RECORDER r·age 1 Lf !!12-!!19-8'/ BRADLEY LAKE HYDRO PROJECT NORTH FORK OF BRADLEY RIVER STAGE=DEPTH+G0 DISCHG=G1*<DEPTH+G0>AG2 DATE TIME BYTE RAW DATI~ MV ----·---------------------·--------------------·----- 11/18/86 !ZHZI : !!l Ql 8'"Ji .L.! 25 11!16 5. i!l 11/18/86 !216 : !!I Ql 829 21 1!!16 4 '~.· . - 11/18/86 12: 1~1!21 831 19 11!16 3.8 DEPTH INCHES ====== 1121. 1!1 8.4 7.6 11/18/86 18: i!I!Z.I 833 2!!1 1 (!16 4.!!1 8.121 DAILY AVERAGE VALUES 11/19/86 !21121: 0!21 835 23 1 !216 4.6 9 '") •"'- 11/19/86 (!16: 00 837 27 11!16 5.4 11!1.8 11/19/86 12: (_ijQI 839 31 11216 6.2 12.4 DAILY AVERAGE VALUES DATA FILE NFORK04 START: 08/06/86 18:00 STOP: 11/19/86 12:20 G1= 121 STAGE IN. ---------- 1 (.1 • 121121 8. 4121 7. 6121 8. !ZI!ZI 8. 5121 9. 21!1 10. 81ZI 12. 4121 10.80 G2= It .I DISCHG CFS ====== !21 Iii 0 !!I !!I 121 Y.l 121 121 TEMP DEG C ---------- :5. 1!1 3. 1!1 3. Ql 3. l!i 3. 1!1 3. !ZI 3. IZI 3 .. ~!J