Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Bradley River Water Quality Report 1985
ALASKA POWER AUTHORITY 1985 BRADLEY RIVER WATER QUALITY REPORT "RECORD COPY 11 RETURN TO BRADLEY O&M FILES fM "T l:.J I, I 0 ,/ BRADLEY LAKE HYDROELECTRIC PROJECT BRADLEY RIVER , KENAI PENINSULA, ALASKA ·~· FEDERAL ENERGY REGULATORY COMMISSION PROJECT NO:l>-8221 -000 Alaska Power Authority_ Hydro/Wood/Coai/Solar/Wind/Geothermai/Conseroation BR Water/107 BRADLEY LAKE HYDROELECTRIC PROJECT 1985 BRADLEY RIVER WATER QUALITY REPORT Prepared by: Woodward-Clyde Consultants and Entrix, Inc. and Stone & Webster Engineering Corporation Anchorage, Alaska BR Water/107 FOREWORD BRADLEY RIVER This water quality report covers data taken over two time frames by Consultants to Stone & Webster Engineering Corporation December, 1984 -May, 1985 Woodward-Clyde Consultants and Entrix, Inc. May 2, 1985 -December 28, 1985 Northern Technical Services, Inc. Contained in Appendix D TABLE OF CONTENTS TABLE OF CONTENTS Section Section Title 1.0 INTRODUCTION 1.1 1.2 1.3 Background Study Objective Summary of Study Results 2.0 METHODS 2.1 2 .1.1 2 .1. 2 2 .1. 3 2 .1.4 2.2 2.2.1 2.2.2 2.2.3 2.2.3.1 2.2.3.2 Field Methods North Fork Gaging Lower Bradley River Temperature Gaging Ice Observation Methods Sediment Sampling Analytical Methods North Fork Discharge and Temperature Lower Bradley River Temperature Data Sediment Sample Analysis Laboratory Techniques Data Analysis 3.0 RESULTS 3.1 3.2 3.2.1 3.2.2 3.2.3 3.3 3.4 3. 4. 1 3.4.2 3.5 BR Water/107 Climatic Conditions North Fork Discharge and Temperature North Fork Stage Data North Fork Discharges North Fork Temperatures Lower Bradley River Temperatures Lower Bradley River Ice Observations Ice Development Breakup Lower Bradley River Sediment Page No. 1-1 1-1 1-2 2-1 2-1 2-1 2-2 2-3 2-4 2-4 2-5 2-5 2-5 2-6 3-1 3-1 3-1 3-2 3-2 3-3 3-4 3-4 3-6 3-7 TABLE OF CONTENTS (CONT'D) Section Section Title 4.0 DISCUSSION 4.1 4 .1.1 4.1.2 4 .1. 3 4.1.4 4.1.5 4.2 4.3 4.3.1 4.3.2 4.3.3 LIST OF FIGURES Lower Bradley River Temperature Predicted Temperature Regime Salmon Emergence Intragravel Temperature Verification of Study Conclusions Conclusions -Pink Salmon Analysis Lower Bradley River Ice Observations Sediment Siltation Sedimentation in Riffle Reach Sedimentation in Tree Bar Reach Figures are included with the text Figure No Figure 1 Figure 2 Figure 3 BR Water/107 Title Bradley Lake Study Area Showing Stream Gage Location Schematic Diagram of Tree Bar Study Reach Showing Locations of Sediment Samples, Temperature Probes and U.S.G.S. Stream Gage Schematic Diagram of Riffle Study Reach Showing Locations of Sediment Samples, Temperature Probes and U.S.G.S. Stream Gage Page No. 4-1 4-1 4-1 4-2 4-2 4-3 4-4 4-5 4-5 4-6 4-6 LIST OF FIGURES CONTINUED Figure No Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 BR Water/107 Title Tripod Equipment used to Extract Freeze Core Samples Freeze Core Sample Air Temperature Data for Homer, Alaska Collected Stage Data on the North Fork Bradley River Stage Data on the North Fork Bradley River Adjusted for Ice Staging Effect Provisional Discharge Data for North Fork Bradley River Surface Water Temperature for North Fork Bradley River Surface and Intragravel Water Temperatures in Tree Bar Reach Surface and Intragravel Water Temperatures in Riffle Reach Ice Observation Locations Mid-Channel Ice in Bradley River During High Tide, Early March, 1985 Sediment Distribution at Riffle Reach Sediment Distribution at Tree Bar Reach LIST OF TABLES Tables are included with the text Table No Table 1 Table 2 Table 3 Table 4 References Appendix A Appendix B Appendix C Appendix D BR Water/107 Title Summary of Ice Observation on the Lower Bradley River During the 1984-1985 Winter Summary of Sediment Sample Characteristics in Tree Bar Reach Summary of Sediment Sample Characteristics in Riffle Reach Comparison of Substrate Size from Visual Estimate and Sieve Analysis Discharge and Climatic Data Water Temperature Data, December, 1984 -May, 1985 Sediment Grain Size Curves Water Temperature Data, May 2 -December 28, 1985 l ( I I . it t ' ' I 1 qt I J 1 •' i , I • ' ' SECTION 1.0 . ' INTRODUCTION· I. :I : ~ 1.0 INTRODUCTION 1.1 Background Water quality concerns of the Bradley Lake Hydroelectric Project in the lower Bradley River are associated with project operation. These concerns were addressed in the FERC Bradley Lake License Application, and accompanying documents using estimates of present water quality conditions and predicted conditions under project operation. However, for project design and finalization of site specific mitigation, more specific data were required. Hence, additional studies were undertak- en to verify estimates relative to existing conditions, and to allow improvement in predictions of the lower river water quality under project operation. 1.2 Study Objective The objective of this study is to collect additional field data to describe existing water quality conditions, and improve reliability and resolution of predictions of these conditions under project operation. Specifically, the program included: 1. Collection of streamflow data on the North Fork of the Bradley River. 2. Collection of surface and intragravel water temperature data in spawning areas presently utilized in the lower Bradley mainstem. 3. Observations of ice processes in the lower Bradley River. 4. Collection of information on particle size and percent fines in the lower Bradley River to characterize substrate and sediment deposition during low flows. BR Water/107 1-1 1.3 Summary of Study Results Both surface and intragravel water temperatures respond to air temper- ature fluctuations. Intragravel temperatures are slightly warmer than surface water temperatures, they change rapidly with changes in surface water temperatures. water appear to be more Exchange between surface and intragravel rapid in Tree Bar Reach. Because of temperature compensation by embryos and the small magnitude of water temperature changes predicted under project operation, dates of emergence are expected to be within natural variation of emergence and outmigration for Kachemak Bay Pink Salmon stocks. Thus, water temperatures under project operation are not expected to alter production of pink salmon in the mainstem Bradley River. Substrate studies in the lower Bradley River focused on the percent of fines contained in spawning areas. The amount of fines present in Riffle and Tree Bar Reaches were within the tolerance level for spawning salmonids. Riffle Reach accumulated more fines in spring sampling than Tree Bar Reach. Greater differences in the percent of fines would probably have been observed without the high flows that occurred in late January. Under reduced flows during project operation there was concern that sediments may accumulate in Riffle Reach that could adversely affect spawning and incubation habitat. Spawning habitat under project operation will be located in the central portion of the channel. These areas experience higher velocities under low flows than presently utilized spawning areas which are generally located along the river margins. It is expected that new spawning areas will exhibit fewer fines than existing spawning areas. BR Water/107 1-2 SECTION 2.0 METHODS 2.0 METHODS 2.1 Field Methods 2.1.1 North Fork Gaging Continuous stage and temperature data were collected on the North Fork of the Bradley River using a Datapod model DP 211 recorder. The recorder was set to record average values every 6 hours. The recorder was installed temporarily, on December 19, 1984, in a pool approximately 100 yards upstream from the confluence of the North Fork with the Bradley River (Figure 1). A large discharge at the end of January partially dislodged the gage causing a shift in the transducer location. The unit was removed from the water on March 6 and reinstalled in its permanent configuration on March 21. To calibrate equipment, discharge measurements were taken on December 10, 1984 and May 2. Measurements were prevented during most other site visits because snow and ice conditions prevented access to the flow measurement site. The measurements were taken near the down- stream end of the pool containing the gage, but above the hydraulic control. The cross section at the measurement location was surveyed on May 2. Some points on the cross section were estimated because ice and snow were present, however, points would not affect the area and wetted perimeter until the discharge exceeded about 80 cfs during the open water season. The minimum elevation of the hydraulic control was also measured. 2.1.2 Lower Bradley River Temperature Gaging Continuous surface and intergravel water temperatures were collected in the Riffle and Tree Bar Reaches of the lower Bradley River using Datapod model DP 2321 recorders. The location of these recorders are shown in Figures 2 and 3. The recorders were set to record the maximum, minimum and average temperatures over 6 hour intervals. The BR Water/107 2-1 surface water temperature probe was fixed within 3 inches of the bed; the intergravel probe was located 18 inches into the gravel in a perforated probe. 2.1.3 Ice Observation Methods Aerial reconnaissances to evaluate the lower Bradley River ice pro- cesses and the Kachemak Bay/Bradley River ice interactions were conducted by flying over the river to observe ice conditions and to collect photographs. Ice thickness was measured and ice characteris- tics were documented during ground reconnaissances; the effects of tidal inflow.on the ice processes at selected sites were also inves- tigated. The dates and activities of the ice observation reconnais- sances are summarized below: Date November 13, 1984 November 20, 1984 December 17-18, 1984 March 7-8, 1985 March 20-23, 1985 May 2, 1985 BR Water/107 Activities Fly-over, photography, comprehensive ground reconnaissance Fly-over, photography, tide effect observation, ground reconnaissance Fly-over, photography, ground reconnaissance Fly-over, photography, comprehensive ground reconnaissance Fly-over, photography Fly-over, photography, ground reconnaissance 2-2 I >- <( cc ~ <( ::!: w J: 0 <( ~ w ~ <( ...J > w ...J 0 <( a: cc en w ... ...J ::§ 0 BRADLEY LAKE STUDY AREA SHOWING STREAM GAGE LOCATION FIGURE 1 G 3tin~l.:l-------___, 3E>VE> ~\f3W.s ·s-ersn aNV 'S38rn:k:f 3~ Vt:f3dVal 'S31cJWVS !N3Vii03S .:::10 SNOilV001 E>NIMOHS H~V3~ ACJUS ~V8 .33Hl .:::10 ~V~E>VIO ~ll V~3HOS 199:.1 1 I I OS 0 @ aBae waaJIS -s-ersn \J .JapJOoat~ a.rqBJadwa J. y SUO!~B001 DU!IdWBS e J9ABJ8E:J pOOMUOUOOfJ9PJV U) aoruds t::::tJ (l ' .. :""";•' ·'· ~~' £ 3~nE>I.:J .l t f t t l t t t f t t t t t t t t t t t i 3E>VE> ~V3l::llS-·s·e>·s·n aNv L.....,.-.--\\::\,t t ' ' ' ' ' ' ' t t ' 9 "J.l. t t t t t t t t t t t 'S380l::ld 3l::lnl Vl::l3d~31 . ¢i t t t t t t t t t t -. ~ ¢~( t t t t t t t t t t 'S31d~VS 1N3~103S .:JO 9 <§ .w t t t t t t t t t t t Q 9 -t t t t t t t t t t ; SNOil V~01 E>NIMOHS Gi <§. / Q ., -~ t t t t t t t . - - -t t ~j t t t t t t ~fit'' tttttt ttt ~Vl::IE>VIO ~11V~3H~S !§ ~ ~ ¢it!ji t t t t t t t ~ t t , -l~<§ti tttttftt tt -~ $' ~~ t t t t t t t t , ; ~ <§ <!j. . : t t t t t t * t t t . ::.:.~:· : .. tj(j~r.j· ttttt.tt .... ,, ... , fj (.j ~,. -· L "J.l. ~-···.-·:·-t t t t t .... t .. t t .. 'f :~: . .,~.;·· · r.; ,.w.h ·.•:o.·.o .. ; l T l l T f f T f -~"::"" :; ;vv-v· ·'······ •-...... . ~ ~ ~ 1/j, • • 0 • 0 •• : .• • t t t t t t .., t •.. ,.. ... .. <iP • • • • • t t t t t ' t t t . •' .. ,.. ., § ~ ~ c§ ~ : "t: ': ~-/ .. ... .... .... • .. .. * ... :: .. ::::·':;:;:. ·~:. ~ 9 ~ @ '1 ~ . . ..... f: ' ' ' ' . ' ' ' ' " ....... ..... ... (j t§ ~ ~ fj ti . ~~.:::~: ~-.'·. . t t t t t t t t t .... ' ' ~ ~ !§ ~ ~ (.j ~! : ; ~-. :. t t t t t t t t t .. . .... . 9 ~ ~ ~ ~ lji <;j ~ 7' ·-: ;. ~: t t t t t t f t t t t -::: .. . ;i I§ (lj ~ ~ ~ Q ~: (.1 .... ;. . t t t t t t t t t t ·: .. , ~ _r.j _clj _c§ (.j -~ _t!j~ .a. 9 "J.l. ~-._., t' Y f t' ...... t' ...... t' t' .,' l T T _::;::_ ~ fj rtj fj l!j Q Q r!j (,j (j 9 t/ (!. .. (.j ':·~ _:t t t t t t t t t t t ~>· ~ ¢ t!j ¢ ~ d) c§ ~ Q ~ ~t t t t t t t t t t ·;,.,'": fit§cW~iit't!j~ ...s' ttttttttt_~·:;::: ~ ~ c§ Q ~ ~ c§ 9 ~-u. t ·' t t t t t ... t .. :--:..:": ... :·:.:· tj ~ ol t.j <§ lj t.ii ~ . \ T t t t t t T t ~·: .......... , 5 I§ _t-J ~ _Q -~ <(I§ f'J .,. , ',. ', ',','. ', ', :L<::: ·::.-.... ~;··: ~ c§ ~ c§ (.j ~ rtj ~ • t t t t t t .., t ...... ,..·.,. .. _ .. .... ~ rtj _tj _lj ~ 1P <tj c§ <ji : t t t t t t t .~· ;::.~·. :--'···.::: _fj _$ _Q _r!j _(j _tj _tj _(.j . ~ ... t t t t t t t t .:~::.-~::"7~ .::~ ) _Q t!j _¢ ~ _d) _r:ii _Q _t!j -t t t t t t t t ':.~ ".,,. c::: .. ·::. • -~ _cfJ -~ _? _9 _lj _'!P •. t t t t t t t t .,..:· .. :: .. ::". .. ,. ..... -~ ii <iP <:9 ~ ~ • t t t t t t t t .... _.,, .... :. ~·:: :::.. ~ ~ c§ ~ ~ ~ (i ~ ¢,9 6 f'j ~ r§ : . t t t t t t t t . ::::: ··:~>·:·:~:. ·::: .. ::. : -~ (j 6 • r.; 71 ... 'l! .... •• • • . • t t t t ' t t t .,.:··::;. '"•:;: ,::•"' ,." !§ ~ -~· -~ _'ll _.,. -".: t t ... t t t t ' ............ .. . ,~:: .,;·~: • -~ _(.j _tj -~ .:.:· t t t t t t t t t ::" ···:::.; ":,,."'.,.. :,. -~ ... ~co"(.f)ttjh~ ·., : f f T T l T l f .;;·:;~·:: . .... . ,.. -~ _..... ~ '¥ -.. :-~-..., t t ... t ' t t t ..... ~-.. ..... _ ...... ,:~ $ (.j -~ _rti~ ... ,: • :.:. : .. •. v t t t t t .., t t ... :··: .. ~':."' ..... ·::: .,. .... Q 9 <tj c§ . ~ ~ .... -~·:. t t t t t t t ". ·~··· " ... , ~::" ·~ ~ Q I} 0 .. :':" ...:.~ _.,,. .. ' J.. t ............ * ..... ·~ ..... ~ I 'II'.,.''"',..~· -).;. -.,."' • -~~~ .. ----.,--;;' T ' ' ' ' .-' ••... ,"" •. . ,,, .,.:"· .....• :--:; 'I>' .. ... ' -':::> ... ~· ~ :·:. . t t t t t t t t ·--:-.:: .. -. . ~... ~:--::. .,.. ;:: -~· .. ;;; ··:::;:. ~ ~· ,:· .... :~:; . ~:..:-·. g . t t t t t t t t "'.:::: ::;: It' ,.. 'II\'' ...... "'" 'II'' .,.. ., ..,.. '1\.. .,. '•II' ~ 'J'II' -... .... -t ,j, t ... .... •,,,. • ... ~ .... ... .. .,. .,,. ....... ... • • . ,,. ...... .,... ... ..... ' ' ' ~ ' f ... . ..... .. • ,,.. ~ •• ,. ..":" ..,.. .,;;: ..... .,,.-: • ..,.~ ·:: .,. •• ·~,··. .,... ~'I' .:: ' t t t ' t ' t . .,... ..... ,_, .. · '' ,,.. ··n•' · '~ . .,,. • '""' "' ·.-'•11•' ... , .... '" 09 ~99:J --.--- 0 @ .. ~: -~:·:. ··:~~ ·~:.~-.}>::~.: .. :· ;:··:-::-·:;: .::.::::~:::·· .. :::· <:: , ... , ... , , , • , , , , , .... :;\~:>·T: SUO!leOOl Bu;~d::: ['·:~:-I ·~-: ~~; ~-~~~ ~~;~n} }};:~~·:.~@~~;'~: ·, ·~.:~~~~j~~~~~":=<2 pOOMUOll00fJ8PJV ~ •. " ........ ,_ .... ,. ............. ~ .... , .................. · · •.. . ................. _..,.._ ........ · a~nJdS[!J SSBJr:'\~_-· '-'~ 2.1.4 Sediment Sampling The sediment sampling program was developed with the following crite- ria: 1) Quantification of sediment variation with depth near the surface was required. 2) A maximum depth of sampling of 18" was deemed adequate in light of salmon spawning activities. 3) The minimum size of sample was based on recommendations of ASTM Test D-422 (Particle-Size Analysis of Soils). 4) Minimizing loss of silt during the sampling process. 5) Sample locations were chosen in known spawning habitats. 6) Comparability of data results over a long time period was required. The Bradley River substrate ranged from 100 lb. boulders to 0.001 mm effective diameter particles. Due to this large size range a freeze core sampling system was developed. The system consisted of a tripod and jacking system, pipe probes and liquid co 2 (Figure 4). By freezing the substrate, an undisturbed and unwashed sample could be removed from the stream bed (Figure 5). In addition, accurate depths could be measured by splitting the sample vertically. The sample probe consisting of a 24 inch long, 1 inch diameter pipe with a pointed, sealed end was driven into the substrate to a depth of 18 inches. Liquid C0 2 was injected into the pipe via a 1/2 11 steel pipe and allowed to flow until the 20 lb bottle was empty. Pressure was regulated to maintain flow of co 2 and to allow the freezing to occur over a 10 to 14 minute period. After the freezing was complet- ed, the tripod and jacking system were used to extract the sample. Typically samples were 6 to 9 inches in diameter and 18 to 20 inches long. This size provides a large enough sample to meet the recom- mended minimum weight established by ASTM. Immediately after the sample was removed the diameter and length were measured. The sample was then wrapped in plastic, taped and placed in a burlap bag for transport. BR Water/107 2-3 For analysis the still frozen samples were placed over boxes divided into 3 compartments, each about 6 inches wide. The excess length of sample was placed into the compartment containing material farthest from the surface material. Each compartment was bagged separately and returned to Anchorage where sieve analyses were performed. 2.2 Analytical Methods 2.2.1 North Fork Discharge and Temperature Data were extracted from the data storage modules and were reduced to provide mean daily stages and temperatures. The recorded stages from the temporary installation, the partially dislodged configuration, and the permanent installation, were adjusted to reference stage data to the same datum. Additional adjustments were made to the data to eliminate ice staging effects. The few measured discharge and stage were developed into a rating curve at the site. This was used to calculate provisional daily discharge data from the adjusted stage data for the periods December 19, 1984 to March 6, 1985 and March 31 to May 2, 1985. The provisional discharges were averaged for each month and the January average compared with the difference between the January averages of the U.S .G. S. provisional data for their Bradley River gages at tidewater and the lake outlet. The topographic charac- teristics of the two drainage basins contributing the flow were compared. The mean daily air temperatures were tabulated and plotted. The water temperature records during several periods in March and April were affected by air temperatures due to shallow or no water over the sensor. Hence water temperatures during these periods were estimated. BR Water/107 2-4 r I r r I II II I TRIPOD EQUIPMENT USED TO EXTRACT" FREEZE CORE SAMPLES .___-------FIGURE 4 I .. '~ :..:t~ ,, ,:..~-·>s.;· ·.""-'·~ .. \ FREEZE CORE SAMPLE FIGURE 5 2.2.2 Lower Bradley River Temperature Data Data were extracted from the data storage modules from both tempera- ture units in the lower Bradley River and reduced to obtain minimum, maximum, and mean daily temperatures of the surface and intragravel flows. Data on one of the two data storage modules for Riffle Reach from December 9 to March 6 was unretrievable from the module. The collec- ted data were tabulated and plotted. 2.2.3 Sediment Sample Analysis 2.2.3.1 Laboratory Techniques Sieve analyses were performed on all samples. In addition, selected hydrometer tests were performed on selected samples taken in December. ~he sieves performed were conducted generally in accordance with ASTM Test Method D-422. The variations from the ASTM method are as follows: 1. All rocks large enough to be retained on a 3" sieve were individually weighed and recorded. Rocks from the December 1984 sampling program were also measured along three mutually perpendicular axes with one axis incorporating the extreme maximum dimension of the rock. 2. All sieves smaller than the #16 were washed. The sieve data were corrected to account for the oversize material and to discount large rocks protruding from the main core of the sample. The correction was based on a plot of rock weight vs. longest dimen- sion and judging an average percentage protruding from the body of the sample. Corrections used are as follows: BR Water /107 2-5 Rock Weight (lb) less than 1.5 l. 505 to 2. 7 5 2.755 to 6.5 6.505 to 20* percent weight used in calculating sample distribution 100 75 50 30 * judgement was used on rocks over 20 lb based on actual sample and rock position 2.2.3.2 Data Analysis Analyses of sediment data consisted primarily of parametric statis- tical tests. Specific procedures and assumptions followed Sokal and Rohlf ( 1969). Tests that were performed included Student's T-test, analysis of variance (randomized block design), and Mann-Hhitney two-sample test. A minimum confidence of 10 percent was used to accept or reject the stated null hypothesis. BR Water/107 2-6 ' J! SECTION 3~o· RESULTS ll: 3.0 RESULTS 3.1 Climatic Conditions Climatic data are tabulated in Appendix A for the winter of 1984-85 and compared with winter conditions in previous years (Figure 6). National Weather Service data were obtained from the Arctic Environ- mental Information and Data Center and from the weather service in Homer. 3.2 North Fork Discharge and Temperature 3.2.1 North Fork Stage Data Collected stage data, adjusted to a constant datum, are shown in Figure 7. These data are tabulated in Appendix A. The general trend from December 20, 1984 through the end of January was a gradual recession. Several short duration peaks resulted from precipitation events during the relatively warm month of January. One peak (December 17-29) was not related to precipitation, but was a result of an ice staging effect. The stage was adjusted to the general recession shape during this period for the purpose of calculating flows using the rating curve (Figure 8). Warm weather combined with precipitation caused a relatively large flood at the end of January. Following the large, short-duration flood, a uniform recession in stage continued into February when cold weather caused another ice staging effect beginning February 7. This ice staging effect was removed from the anticipated recession curve for the calculating discharges using the rating curve (Figure 8). flow recession was believed to continue into late March. BR Water/107 3-1 purpose of The general Two short periods of increased stage at the end of March and beginning of April were likely caused by ice formation and were modified for discharge computations. A period in mid-April was also modified. March to May the stage was estimated to decline followed by a gradual stage increase. 3.2.2 North Fork Discharges The provisional discharges for the North Fork Bradley River during the period of record are shown in Figure 9. The data are tabulated in Appendix A. The flood at the end of January was estimated to be approximat.ely 145 cf s. In January, the mean North Fork discharge of 23.5 cfs represented less than half of the estimated mean monthly flow of 66 cfs in the unregulated portion of the basin (that part not used for power generation). Although the North Fork drainage basin flow is estimated to be about 90 percent of the total unregulated basin flow (about 85 percent when the Middle Fork is diverted), it would be less during the winter, as explained below. Above 2,000 ft. elevation most winter precipitation falls as snow and therefore does not contribute to the discharge of the North Fork. As a result only the area below 2,000 ft. elevation (approximately 50 percent of the drainage basin) was assumed to contribute flow to the North Fork. A review of the provisional discharge records for the Middle Fork Bradley River (Appendix A) illustrates this point. The percentage contribution of the North Fork to the total unregulated flow would thus be expected to vary from about 40 percent to 90 percent or more during the year, depending on climatic conditions. 3.2.3 North Fork Temperatures The provisional North Fork water temperatures are shown in Figure 10. These data are tabulated in Appendix A. The temperatures were uniform BR Water/107 3-2 { ' 8 I • MAXIMUM TEMPERATURE 1974-1985 • MAXIMUM TEMPERATURE 1974-1985 II • MAXIMUM TEMPERATURE 1974-1985 )> o MINIMUM TEMPERATURE 1974-1985 o MINIMUM TEMPERATURE 1974-1985 o MINIMUM TEMPERATURE 1974-1985 :0 .& AVERAGE TEMPERATURE 1974-1985 .& AVERAGE TEMPERATURE 1974-1985 .&AVERAGE TEMPERATURE 1974-1985 D. AVERAGE TEMPERATURE 1984-1985 D. AVERAGE TEMPERATURE 1984-1985 -I u: m ~ ~ M! "'0 :::> 11 m 1- :0 ~ -I ~ w G) a. 0 ::l!l ~ c ~ c :0 m m :0 JJ 0 )> ~ -20 m s;: ):> 1 FEBRUARY 1 MARCH 1 APRIL (J) 23 0) ~ :0 r 0 co ("U!) 3~V.LS 0 >-a: <( :::> a: CD w l.L >-a: <( :::> z <( -, a: w CD ~ w () w 0 0 co ("U!) 3~V.LS ~ ~ i-- ~ f.. f- >-- ~ ~ ~ ~ L ~ c ._ ~ ~ 0 _J a: a_ <( I () a: <( ~ COLLECTED STAGE DATA ON THE NORTH FORK BRADLEY RIVER L...---------FIGURE 7___, 0 co CUI) 3E>\f l.S - 0 >-II ~ ::J II (l) w LL >-II ~ ::J z ~ J II w (l) :2 I w u w 0 ( ( 1 CU!) 3E>\f l.S F: r [ !- ---~ -:2 .._ -- f- - t I ~ t-,.. .....J f.. II 1-Cl. ~ ~ ..... E ~ ~ 0 STAGE DATA ON THE NORTH FORK BRADLEY RIVER ADJUSTED FOR ICE STAGING EFFECTS FIGURE 8 I I 0 0 ... (SJ::>) 30~VHOSIO 0 >-a: <( ::J a: CD w u.. >-a: <( ::J z <( -, a: w CD ~ w (.) w Cl 0 0 ... ( (SJ::>) 30~VHOSIO --- --- - - - -- - -1- r- -- - ,... .. - 0 ....J a: a_ <( I (.) a: <( ~ PROVISIONAL DISCHARGE DATA FOR NORTH FORK BRADLEY RIVER ....__ _______ FIGURE g~ (00 ) 31::10.1 Vl::l3d~3.1 0 >-0: <( :::::> 0: (l) w LL ~ <( :::::> z <( --, a: w (l) ~ w () w 0 (0 0 ) 31::10.1 Vl::l3d~3.1 0 .....1 0: 0.. <( I () a: <( ~ SURFACE WATER TEMPERATURE FOR NORTH FORK BRADLEY RIVER .....___ _______ FIGURE 10 from December 20, 1984 through March 6. The water temperatures during the period March 21 through May 2 were more variable than the previous period. The difference in temperature characteristics may result from the location of the temperature sensor. The temporary and permanent installation of the temperature sensor monitors the near surface temperatures in the stream at low discharges. At low discharge, the water temperature appeared to respond more readily to fluctuations in air temperature. Some data were negative during cold weather periods; these data were deleted from Figure 10 and the table Appendix A. The dislodged sensor was about 2 ft lower than it had been in the tem- porary installation; it was thus measuring the water temperature deeper in the pool and it varied little with changes in air tempera- ture. 3.3 Lower Bradley River Temperatures Surface and intragravel water temperatures in Tree Bar and Riffle Reaches of the lower Bradley River are shown in Figures 11 and 12. These data, and the daily minimums and maximums for the period, are tabulated in Appendix B. The mean daily surface water temperature in Tree Bar Reach ranged from 1.8° C to -O.l°C. Maximum and minimum recorded temperature during the period were 2. 0°C and -0.1 °C. A diurnal temperature fluctuation of over 1.0°C was observed during some warm days in April. Intragravel water temperatures in Tree Bar Reach were generally 0.2-0.3°C warmer than the surface water temperatures. A temperature lag was evident only in cases where the surface water temperature changed rapidly, such as in December. The intragravel water tem- perature changed every 6 hours with changes in surface water tem- perature. The minimum and maximum intergravel temperatures during the period were -O.l°C and 2.0°C. BR Water/107 3-3 Surface water temperatures in Riffle Reach were very similar to those in Tree Bar Reach. Diurnal temperature fluctuations were evident in late April when the weather had warmed. Minimum and maximum surface water temperatures during the period were -0.3°C and 2.6°C. Intragravel water in Riffle Reach appeared to change less readily with changes in surface water than did Tree Bar Reach, and thus more of a lag was evident than at Tree Bar. With constant surface water temper- atures intragravel water temperature was 0.2 to 0.3°C warmer. As surface water temperatures warmed in April, intragravel temperatures lagged by 0.1 -0.2°C for several days in a row. Minimum and maximum intragravel temperatures were 0.2°C and 1.4°C for the period. 3.4 Lower Bradley River Ice Observations A summary of ice observations in the Lower Bradley River during the 1984-1985 winter are provided in Table 1. The locations referenced are shown in Figure 13. below. 3.4.1 Ice Development Results of these observations is provided Ice development in the Bradley River is influenced by both tidal and riverine ice formation. Ice floes are created and transported during the tidal cycle and affect the ice formation in the lower river. In the Upper Bradley River, outside of tidal influence, ice develops initially on channel margins in still water reaches. BR Water/107 3-4 r a: w 1-a: <C w ~ 1-...1 <C w ~ > w <C 0 a: <C (!) u. <C a: a: ~ 1- C/) 3'; 0 • (Oo) 31:in.LV~3d~3.L -I >-a: <( ::> a: CD LU u. a: LU CD ~ LU (.) LU 0 -(00 ) 3~n.L V~3d~3.L I SURFACE AND INTRAGRAVEL WATER TEMPERATURES IN TREE BAR REACH FIGURE 11 a: ~ a: < w~ t-_, <w ~> w< (.)a: <CI u.< a:: a: :::)1-C/)~ 0 • COo) 31::1n~ Vl::l3dV.3~ ... I ...J a: a... <t SURFACE AND INTRAGRAVEL WATER TEMPERATURES IN RIFFLE REACH ....__ _______ FIGURE 12 Table 1. Summary of Ice Observations on the Lower Bradley River During the 1984-1985 Winter Date Location 11/13 11/20 12/17-18 3/7-8 3/20-23 5/2 Tree Bar Reach A,FS,S s s I,S s CA,S,SI Bend Between Tree FS s s C,F,HC S,SI S,SI Bar and Riffle Reaches Riffle Reach FS s A,G,S A,F,G,HC,S I,G,S,SI CA Eagle Pool C,S G,I I C,F,G G,I,SI 0 RM 4.0 G,I,S G,I I C,G I 0 RM 3.5 G,I,S G,I I C,G I 0 RM 3.0 G,I,S G,I I C,G I 0 Fox Farm Creek I,S G I G,HC,I G,S 0 A: Anchor Ice C: Continuous Ice Cover CA: Candled Ice F: Flooded Ice FS: Frazil Slush G: Grounded Ice HC: Hummocked Ice I: Ice Floe L: Open Water Lead 0: Ice Free s: Shore Ice SI: Snow Ice BR Water/107 \ AM 4.0 RM 3.0 0 500 FEET RM-RIVER MILE I I / /RM 5.0 I BEND DOWNSTREAM FROM TREE BAR ICE OBSERVATION LOCATIONS FIGURE 13 In the lower Bradley River, ice development is initiated in the tidal flats. During high tides, Kachemak Bay water floods the tidal flats. As the tide recedes, shallow ponds are formed which freeze into ice sheets. The ice sheets are transported during the next high tide, sheet ice is formed each tidal cycle. The limits of ice transpor- tation during a tidal cycle extended from about 2 miles southwest of the Russian Village at low tide to Eagle Pool. Unobstructed ice movement at higher tides could be expected to extend to just down- stream of Tree Bar Reach. During freeze-up in the still water reaches of the Bradley River, ice begins to develop along the shore and in very shallow water. The shore ice forms a long border attached to the river bank and grows laterally out over the channel. In the shallows, ice anchors to the channel bed where water levels are receeding and velocity has slowed. This anchor ice was observed at Tree Bar Reach, Riffle Reach and as far downstream as the gravel bar at the head of Eagle Pool. The shore ice and anchor ice are not transported during the tidal cycle. In the 1984-1985 winter, ice thicknesses ranged roughly from 4 to 6 inches by early February. A continuous ice cover is formed to culminate the development of tidal and riverine ice. Hummocked ice characterized the river downstream of Fox Farm Creek. Upstream from Riffle Reach, mid-channel open leads existed where water velocities were high, such as at Tree Bar Reach. On March 8, the ice was 15 to 18 inches thick topped with 4 to 6 inches of snow and slush. During periods of continuous ice cover, hinge cracks developed from Riffle Reach to the bend downstream from Tree Bar Reach. The ice hinged downward from the shore fast ice at low tide. While at high tide, the ice hinged upward while remaining fastened to the shorefast ice. The ice thickness and continuity kept the water from flowing into the lower area by the bank. Further downstream, where the tidal range is greater the hinge cracks were severed. The mid-channel ice floated within the channel banks while water overflowed into the tidal flats (Figure 14). BR Water/107 3-5 Tidal overflow of grounded ice increased ice thicknesses by developing snow ice. By late March, the thicknesses above the maximum tide zone (Transect 4 Tree Bar) ranged from 12 to 18 inches. In the tidally influenced areas, ice depths to 2 feet were common. Although tidal overflow of the ice was not observed during aerial or ground recon- naissances, silt was observed on exposed ice surfaces in Eagle Pool and Riffle Reach. The sediment source is assumed to be tidal waters as the river sediment load is near minimum during the low winter flows. 3.4.2 Breakup Breakup in the Bradley River is also influenced by both the tidal cycle and riverine processes. The tidal cycle is the primary mecha- nism for ice breakup in the lower river. Further upstream, the ice cover melts as ambient temperatures and river discharge increase. Breakup was observed from March 20 to March 23, 1985. In the lower river, the ice cover disintegrates from the mouth in the upstream direction. The ice floes are transported into Kachemak Bay by the outgoing tide. Upstream of the tidal breakage front, melting enlarges open leads in the ice cover. The shorefast ice melts progressively. On March 20-23, 18 inches of shore ice was observed on the gravel bars in Riffle Reach. By May 2, the shore ice depth had decreased to 6 inches. Meanwhile, the open leads enlarge and become continuous; ice floes are formed as the open leads join. Most ice floes are carried downstream into Kachemak Bay by the Bradley River current and by tidal action. However, some ice floes ground on shore ice, gravel bars, or on top of the banks. On May 2, 2 ft thick ice floes were grounded on the shore ice on the gravel at Riffle Reach; these had become frozen to the shore ice and a few had two layers of ice floes on the shore BR Water/107 3-6 I MID-CHANNEL ICE IN BRADLEY RIVER DURING HIGH TIDE, EARLY MARCH, 1985 ..___ _______ FIGURE 14 ice. Downstream from Riffle Reach, the Bradley River was free of ice. The shore ice and grounded ice floes are the only remnants of the continuous ice cover. 3.5 Lower Bradley River Sediment A summary of the sediment sample characteristics in Tree Bar and Riffle Reaches are provided in Tables 2 and 3. Grain size curves for all samples are provided in Appendix C. Substrate was classified visually in the Bradley River for inclusion in the habitat simulations conducted for. the feasibility studies, i.e. Instream Flow Report (Woodward Clyde & Assoc.). Since the Bradley River remains turbid throughout the year, accuracy of visual estimates required verification. Results of sieve analysis were compared with visual estimates of substrate size (Table 4). Visual evaluation generally classifies substrates one class higher than results of sieve analyses. Although the samples from the upper zone were used in the comparison, a smaller substrate size for the sieved samples is to be expected. Sediment samples collected during this study indicate that the rela- tive abundance of fine silts (less than 0.003 in. diameter) varies considerably between the two reaches, between stations within the same reach, and between replicates at the same station. During the Decem- ber 1984 sampling period, the relative abundance of fine silts was significantly greater at Riffle Reach than at Tree Bar Reach (T-test, T-3.34, P-0.01). This difference existed in the means for the reaches as well as at all three depths. During the March sample period, the relative abundance of silts at both reaches had increased slightly; however, the difference was not statistically significant from December (T-test, T=0.59, P-0.10). In December 1984 at Tree Bar Reach, 1.0 percent of the substrate consisted of fine silts, while in March, this had increased to 1.2 BR Water/107 3-7 percent. Riffle Reach demonstrated a similar increase, averaging 4.5 percent in December 1984 and 4.8 percent in March. The difference in the relative abundance of fine silts between the two reaches in March was significant (T-test, T-6.34, P-0.01). Considerable variation in the relative abundance of fine silts existed within the two reaches. During December 1984, the relative abundance of fine silts at Tree Bar Reach ranged from 0.4 to 0.8 percent at the surface and from 0.4 to 3.0 percent 18 inches below the surface. Greater variation was found at Riffle Reach during December 1984 where fine silts comprised 0.7 to 7.8 percent of the surface material and 0.9 to 12.1 percent of the material 18 inches below the surface. A similar level of variation existed in March. At Tree Bar Reach, fine silts represented 0.3 to 2.7 percent of the surface material and 0.4 to 2.7 percent of the material 18 inches deep. At Riffle Reach, 0.8 to 6.8 percent of the material at the surface consisted of fine silts and 5.2 to 7.1 percent of the material 18 inches deep consisted of fine silts. In some cases, this level of variability existed at a single station in the same month. BR Water/107 3-8 r Table 2. Summary of Sediment Sample Characteristics in Tree Bar Reach Water Sample Percent Passing Location Sample Date Depth Dia Length D50 (mm) 200 Sieve (in) (in) (in) Zone A Zone B Zone C Zone Z Zone B Zone C 1 1 Mar 10 5 22 12.3 81.0 35.1 0.4 0.5 1.4 2 Mar 10 8 20 20.0 42.2 25.8 0.5 0.6 1.3 2 1 Dec ---76.6 49.4 35.9 0.5 0.7 1.4 2 Dec ---46.5 30.6 63.1 0.8 0.9 1.0 1 Mar 3 9 22 47.4 34.0 81.0 0.3 0.6 0.5 3 1 Mar 10 5 22 9.0 30.1 56.5 2.7 2.7 0.8 2 Mar 10 5 17 43.4 31.9 27.7 2.2 3.9 2.7 4 1 Dec ---22.3 22.2 75.0 0.4 0.4 0.4 1 Mar 3 4 18 26.8 23.5 29.6 0.3 0.7 0.6 2 Mar 3 5 22 24.4 41.6 56.3 0.4 0.5 0.4 5 1 Dec ---24.3 24.0 9.5 0.5 0.6 2.5 2 Dec ---21.2 18.9 9.0 0.6 1.2 3.0 1 Mar ---29.1 42.3 24.9 0.6 0.3 2.5 BR Water/107 Table 3. Summary of Sediment Sample Characteristics in Riffle Reach Water Sample Percent Passing Location Sample Date Depth Dia Length D50 (mm) 200 Sieve (in) (in) (in) Zone A Zone B Zone C Zone Z Zone B Zone C 1 1 Dec 7 5 20 37.2 23.0 7.5 1.8 4.6 4.5 2 Dec 7 5 20 45.1 20.5 18.6 1.1 4.8 4.6 1 Mar 8 8 22 27.2 16.5 25.3 6.3 9.8 5.4 2 1 Dec 2 6 24 37.2 19.6 21.5 0.7 2.8 0.9 2 Dec 3 4 20 13.4 -14.4 1.8 -1.5 1 Mar 1 7 22 25.6 24.6 14.2 6.8 3.2 6.3 3 1 Dec 4 6 19 11.0 9.2 18.4 7.8 9.1 7.4 2 Dec 5 8 20 27.5 8.7 11.2 1.3 0.9 12.1 1 Mar 6 7 23 23.6 18.0 5.9 1.9 6.0 6.5 2 Mar 6 6 22 25.5 5.0 5.2 3.0 8.3 7.1 4 1 Mar 8 6 19 21.3 21.1 46.6 1.0 2.1 6.2 2 Mar 8 7 22 28.0 37.8 43.6 0.8 1.3 5.2 5 1 Mar 12 7 18 34.3 10.2 15.5 2.5 9.2 6.6 2 Mar 12 6 16 29.9 16.2 -2.1 4.3 BR Water /107 Table 4. Comparison of Substrate Size from Visual Estimates and Sieve Analysis. Freeze Core Sampling Location Tree Bar 2 3 4 5 Riffle 1 2 3 4 5 BR Water/107 IFIM Transect 6 4 2 1 - 8 6 4/5 L, 3 1 12.3 76.6 9.0 22.3 34.3 37.2 37.2 11.0 21.3 34.3 Sieve Samples D50 (mm) Visual Estimate Mean Class (M) Class 2 3 4 20.0 16.2 8-32 22-64 46.5 47.4 56.8 32-64 32-64 43.4 26.2 8-32 32-64 26.8 24.4 24.5 8-32 8-32 29.0 31.7 8-32 45.1 27.2 54.75 32-64 64-130 13.4 25.6 25.4 8-32 32-64 27.5 25.5 23.6 21.8 8-32 32-64 28.0 24.7 8-32 32-64 27.0 31.7 8-32 32-64 SECJ'ION;'4~0 DISCUSSION 4.0 DISCUSSION 4.1 Lower Bradley River Temperature 4.1.1 Predicted Temperature Regime The predicted annual temperature regime of the lower Bradley River project conditions was estimated from mean temperatures and discharge rates from Bradley Lake and from the basin below the lake. Estimated surface water temperatures from April through August are anticipated to be similar to, or slightly warmer than, natural temperatures. Warmer water temperatures are expected from Bradley Lake outflow during this period as the decreased volume of water is more quickly heated by warm air temperatures over present conditions. From September through freezeup in November, temperatures are anticipated to be slightly cooler with a decrease of 2°C or less as smaller flows will cool relatively faster than current flows in response to air temperatures. Anticipated temperatures and flows for December through March are similar to natural conditions. 4.1.2 Salmon Emergence Changes in surface water temperatures can alter intragravel water temperatures which are important to incubation of salmon embryos. The rate of incubation is closely related to water temperature. Warmer or cooler water temperatures in the intragravel environment could, respectively, accelerate or retard embryo development, changing emergence time. Of the salmon species using the Bradley River, pink salmon have the highest potential for changes in emergence timing under project operation. Pink salmon spawn in mainstem habitats where changes of water temperatures are expected. Pink salmon generally spawn in the Bradley River during the second half of August, with fry emerging during April of the following year. Cooler water temperatures predicted for the Bradley River during the fall months under project operation may slightly delay pink salmon BR Water/107 4-1 emergence timing. However, the emergence date is not expected to exceed the natural variation in emergence and out migration. In Kachemak Bay, the annual variation of pink salmon emergence and out migration timing ranges from late March through May (Tom Schroeder, ADF&G Homer, per. comm 1985). Coho and chum salmon emergence timing are not expected to be affected by an altered temperature regime in the Bradley River. 4.1.3 Intragravel Temperature There are three factors contributing to intragravel water tem- peratures; infiltrating surface water; groundwater or subsurface flow; and ground temperature. The relative contribution of each of these components varies on a site specific basis. However, changes in surface water temperatures are not expected to result in changes in intragravel water temperatures of the same increment. The influence of groundwater or subsurface flow and ground temperature would dampen the surface water temperature changes effect on intragravel tern- peratures. In Tree Bar Reach, intragravel temperatures are slightly warmer than surface water temperatures and do not appreciabilly lag surface water temperatures. This indicates that groundwater has little influence on intragravel temperatures in this reach. Changes in surface water temperatures under project operation would likely result in similar changes in intragravel water temperatures. In Riffle Reach, intragravel water temperatures are slightly warmer and do not respond to changes in surface water temperatures as rapidly as Tree Bar. This indicates that subsurface flow and ground tempera- ture may buffer intragravel temperatures in this reach. 4.1.4 Verification of Study Conclusions Experimental studies show that there is a compensation mechanism for eggs developing at colder temperatures. Development rates of embryos 0 0 are expressed in temperature units. (T. U. = 1 above 0 C for a 24 BR Water/107 4-2 r hour period). Total temperature units required for emergence, or complete yolk absorption, have been estimated for Skagit River, Washington pink salmon populations (Graybill et al. 1979). 0 In the Skagit River experiments, mean temperature differences 1 C or less resulted in 2-5 days difference in incubation time to complete yolk absorption (CYA). Species Pink Salmon CYA -Skagit River Experiments Mean Temperature (oC) Fertilization Date T Mean T.U. Date of CYA 5.1 944 Oct. 5 Apr. 8 4.9 921 Oct. 13 Apr. 18-21 4.8 902 Oct. 5 Apr. 10-12 4.1 676 Oct. 5 Apr. 8-11 Days to CYA 185 187-190 187-189 185-188 The data suggest that minor changes in water temperature do not significantly alter the incubation period. At lower temperatures, fewer T. U. 's were required to complete development, thus emergence time remained approximately the same. The variation in total T. U. 's at low temperature shown in a few studies on pink salmon (Graybill et al. 1979) suggests that the summation method is not an accurate predictor for this species as well. There presently are insufficient data on pink salmon incubation to develop the type of model Alderdice and Velsen (1978) developed for chinook salmon. 4.1.5 Conclusions-Pink Salmon Analysis Pink salmon in the Bradley River are expected to exhibit temperatur~ compensation and slight delays in emergence timing if project BR Water/107 4-3 operation results in projected lower water temperatures during the fall. The period of temperature data collection was not sufficient to compare T.U.'s available for incubation during 1984-1985. Since data on water temperatures, intragravel temperatures, and incubation requirements lack sufficient resolution for a detailed analysis of temperature units, an alternative analysis was undertaken. Mean monthly surface water temperatures can be used to approximate the mean incubation temperature. Pink salmon spawn in the Bradley River primarily during the last two weeks in August, with fry emerging during April of the following year. If the predicted mean monthly temperatures for August through April are used to approximate the mean incubation temperature, the pre-project mean incubation temperature is 2.2°C, while the with-project mean incubation temperature is 1.9°C. A difference of 0. 3°C should not have serious impacts on emergence timing or fry survival. 4.2 Lower Bradley River Ice Observations Lower flows under project operation may result in increased ice thickness during winter. Since the volume of water will be less in the fall, water temperatures will cool more rapidly. Stream flows will remain fairly stable throughout the winter, causing the water to remain in contact with the ice. This will allow ice to continue to grow throughout the winter. As a result, thicker ice may develop during project operation. Steady winter stream flow in the mainstem should, however, contain sufficient velocities to prevent anchor ice formation. As currently exists, with receeding streamflow and spawning occur in the high flow margins of the channel, anchor ice growth may result in embryo mortality by freezing redds. During the pre-emergence studies in March 1984, smaller, less developed embryos and fry were found in areas influenced by ice (WCC 1984). BR Water/107 4-4 I The relative impact of the potential for increased ice growth is anticipated to be small. There will be a much smaller number of frozen redds during project operation than are currently experienced, since most of the redds which currently freeze are in areas that will be unavailable with project spawning flows. Much more spawning will take place in the thalweg of the channel, which will remain wetted during project operation. 4.3 Sediment 4.3.1 Siltation Siltation is an important consideration in evaluating spawning and incubation habitat in the lower Bradley River. The Bradley River transports a relatively light load of suspended sediments for a glacial system. Most of these particles appear to remain in suspen- sion as long as velocities are greater than 0.5 fps. As the incoming tide slows the river flow velocities the depth and top width increase; silt particles are deposited over a broad expanse of the channel. As the tide recedes, the velocities increase. The normal flow velocities present in the main channel without tidal influence remove much of the silt from these areas and transport it downstream. Silt tends to accumulate in areas dewatered under low-tide conditions or in other low-velocity areas. In the Bradley River spawning occurs during the high-flow period. A major factor influencing production of spawning area is the effect of low winter flows on embryo survival. As flows decrease during winter, spawning areas may become dewatered or silted. Spawning areas presently utilized in the mainstem Bradley River are located along the margins of the stream as fast velocities during the high flow period preclude the use of the center portion of the channel. Many of these existing spawning areas are dewatered or have low velocities during the incubation period that result in sediment accumulation. Increased sedimentation may be detrimental to salmon populations. BR Water/107 4-5 4.3.2 Sedimentation in Riffle Reach Sediment deposition in Riffle Reach may be detrimental to salmon incubation. Sediment accumulates in this reach during the low winter flows. The heaviest sediment accumulations have been noted in de- watered and low-velocity areas. In previous years, depositions of silts up to 0.3 ft. were noted in dewatered areas in Riffle Reach. Deposition observed in spring 1985 was notably lighter. Late January 1985 high-flow events may have removed much of the sediment, dis- torting the results of the substrate samples from "normal conditions". Figure 15 presents the percent fines from Riffle Reach substrate samples. Temperature data collected in Riffle indicates that exchange between intragravel and surface waters is not as efficient as in Tree Bar Reach. This is indicative of streams with higher levels of sedimentation. Pre-emergent sampling conducted in March 1984 found fewer live eggs and alevins in Riffle Reach than at Tree Bar Reach. Stations 1, 2 and 3 in Riffle Reach generally sampled existing spawning areas, while Stations 4 and 5 sampled spawning habitat which would become available under project operations. (High velocities during high summer flows preclude its use presently). These stations had lower percent fines in upper zones in March as compared with Stations 1 and 2. Since the potential spawning habitat is located more in the center portion of the channel, it experiences higher velocities (even under low flows) than the existing spawning habitat. 4.3.3 Sedimentation in Tree Bar Reach Substrate samples collected in Tree Bar Reach show little difference between percent fines in the surface layers in December and March. Since this reach is generally not influenced by tidal backwater, this is to be expected. Water temperature data collected in Tree Bar Reach indicate good exchange between surface and intragravel water. This indicates that the substrates are relatively free of silts and sands. BR Water/107 4-6 I 1 5 0 0 UJ iii 1 Ci.) • • 0 • • 5 0 0 N '*' 0 (!) z Ci.) (/) <C • a. 0 1-• z w 0 (.) 1 a: 5 w a. 0 0 • • 0 • I I 2 • c c • • 0 0 • • • 8 I 3 STATION &ZONE A DEC. 0 ZONE A MAR 8 § &ZONE B DEC. OZONE B MAR c 0 0 fJ 4 ZONE C DEC. o ZONE C MAR. I 0 8 I I 4 5 SEDIMENT DISTRIBUTION AT RIFLE REACH BAR --------FIGURE 15 Figure 16 illustrates the percent fines in Tree Bar Reach samples. Very little difference exists between December and March samples, and little difference is evident between depths. During the pre-emergent sampling conducted in March of 1984, more embryos and fry were located in Tree Bar Reach than elsewhere in the river. This indicates that sedimentation does not have a substantial adverse effect on incubation in Tree Bar Reach. BR Water/107 4-7 w > 1 !:Y 1 C/) 0 0 C\1 '*' (!) !:; gs ~ 1-z w ~ 1 w a. 5 0 5 0 5 0 0 ~ 0 t 0 ~ I I 2 A ZONE A DEC. oZONE A MAR. B 1=1 !::l &ZONE 8 DEC. OZONE 8 MAR. 0 0 lil • A ZONE C DEC. 0 ZONE C MAR. 0 0 I 3 STATION ~ § I I 4 5 SEDIMENT DISTRIBUTION AT TREE BAR REACH '----------FIGURE 16 REFERENCES '' i REFERENCES Alaska Power Authority 1984. Additional Information to FERC License Application. Bradley Lake Hydroelectric Project. Alderdice, D. F. and F. P. Velsen. 1978. Relation between temperature and incubation time for eggs of chinook salmon (Oncorhynchus Tshawytscha). J. Fish. Res. Board Can. 35.69-75. Bailey, J. E. and D. R. Evans. 1971. The low-Temperature threshold for pink salmon eggs in relation to a proposed hydroelectric installation. Fish. Bull. 69:587-593. Graybill, J.P., R. L. Burgner, J. C. Gislason, P. E. Huffman, K. H. Wyman, R. G. Gibbons, K. W. Kurka, Q. J. Stober, T. W. Fagnan, A. P. Stayman, and D. M. Eggers. 1979. Assessment of the reservior-related effects of the Skagit Project on downstream fishery resources of the Skagit River, Washington. Final Report for City of Seattle by University of Washington Fisheries Research Institute, Seattle, Washington. Iwamoto, R. N., E. 0. Salo, M.A. Madej, and R. L. McComas. 1978. Sediment and water quality: a review of the literature including a suggested approach for water quality criteria. U.S. Environ. Project. Agency. EPA 910/9-78-048. BR Water /107 Raymond, J. A. 1981. Incubation of fall chum salmon Oncorhynchus keta (Walbaum) at Clear Air Force Station, Alaska. Alaska Department of Fish and Game Informational Leaflet No. 189. Juneau, Alaska. Shelton, J. M. 1953. "The hatching of chinook salmon eggs under simulated steam conditions." Prog. Fish-Cult. 17:20-35. Woodward Clyde & Assoc. 1983. "Instream Flow Report". BR Water/107 r APPENDIX A ' -~ ' I Climatic Data Table No. Table A-1 Discharge Data Table No. Table A-2 Table A-3 Table A-4 Table A-5 Table A-6 Table A-7 Table A-8 D-BL-108 APPENDIX A DISCHARGE AND CLIMATIC DATA Title Air Temperature for Homer, Alaska Title Lower Bradley River Flows and Observations During the Study Period Stage Discharge and Temperature at North Fork Bradley River Provisional Discharge Data for Bradley River at the Outlet of Bradley Lake Provisional Discharge for the Lower Bradley River Near Tidewater Provisional USGS Discharge for the Middle Fork Bradley River at Diversion Provisional USGS Discharge Data for Upper Bradley River Provisional USGS Dishcarge Data for Barbara Creek Near Seldovia AIR TEMPERATURE FOR HOMER, ALASKA OCT NOV DEC JAN FEB MAR APR 1974-1982 1983 1974-1983 1984 1974-1983 1984 1974-1984 1985 1974-1984 1985 1974-1984 1985 1974-1984 1985 DATE MAX MIN AVE AVE MAX MIN AVE AVE MAX MIN AVE AVE MAX MIN AVE AVE MAX MIN AVE AVE MAX MIN AVE AVE MAX MIN AVE AVE 1 54 27 43 46 45 3 31 33 41 5 26 34 43 -8 23 41 45 12 31 34 41 8 27 30 48 16 34 10 2 52 28 41 46 so 4 30 30 40 0 24 37 40 -10 22 33 49 5 30 36 41 10 29 25 46 15 33 16 3 54 25 42 44 42 1 29 32 40 -3 21 36 44 -10 22 33 49 7 29 36 42 10 29 23 48 12 34 21 4 54 30 43 40 42 3 30 31 42 -9 23 38 45 -14 22 34 43 5 29 35 47 -2 29 35 47 18 35 23 5 53 29 42 45 47 4 29 39 43 -10 24 36 42 -17 20 30 43 5 28 33 45 -2 30 34 46 24 36 24 6 51 29 42 40 48 10 30 37 45 -12 24 36 44 -8· 20 31 42 0 27 29 46 8 31 33 46 21 35 29 7 51 26 40 39 51 10 33 34 49 -9 24 33 44 -12 20 38 42 4 25 23 45 4 29 27 46 20 35 32 8 55 25 40 34 so 10 32 32 42 -9 21 33 40 -10 19 38 45 1 24 22 48 -1 30 33 47 24 35 28 9 54 23 39 41 49 15 32 28 38 -7 20 25 43 -10 22 38 43 -2 24 18 48 4 31 35 so 27 38 22 10 52 24 39 49 49 6 32 27 42 -4 21 28 44 -2 24 41 46 -1 23 14 51 0 30 35 49 22 35 18 11 52 26 40 48 49 3 33 24 41 -2 21 24 45 -1 23 35 43 -2 22 1 2 44 3 30 34 48 20 33 14 12 50 26 42 43 45 12 34 20 41 -5 22 25 43 -13 21 30 44 -6 20 10 46 -1 30 33 46 14 33 13 13 52 29 41 41 44 9 31 19 40 -9 23 15 44 -10 22 31 44 -s 21 10 44 -1 29 30 48 14 34 17 14 54 25 41 39 42 9 30 32 42 4 22 17 47 -4 25 31 43 -2 21 7 43 9 29 33 44 24 35 25 15 52 25 40 44 45 13 28 38 40 2 23 27 44 3 28 33 41 -7 f9 10 48 6 30 27 47 20 35 36 16 so 28 41 45 42 8 26 36 44 -s 24 38 41 1 28 35 40 -2 21 7 46 5 30 27 47 23 35 34 17 so 23 40 45 40 4 24 33 42 -9 24 39 43 5 30 40 41 -6 22 8 47 13 32 28 49 24 35 35 18 so 20 38 39 42 7 27 33 40 -5 22 40 42 3 30 39 44 -6 21 10 47 15 31 33 52 21 36 31 19 so 23 38 39 44 9 29 37 39 4 25 36 41 10 28 39 43 -6 22 1 2 48 11 32 32 so 20 36 28 20 51 24 38 37 43 11 31 42 42 9 28 24 42 -4 28 42 39 -1 23 13 48 3 34 33 48 20 38 36 21 so 25 39 42 45 13 33 36 40 -2 27 32 42 -5 30 39 44 0 24 12 45 10 35 34 so 26 38 36 22 so 23 38 39 44 13 32 30 40 -2 26 33 42 6 27 36 44 4 26 9 46 -1 33 37 so 22 37 32 23 53 20 38 36 44 11 30 26 42 -1 25 37 45 5 25 37 41 5 25 16 47 -1 30 33 55 23 38 35 24 so 22 39 34 47 9 30 30 45 1 27 29 47 -1 26 35 41 5 26 25 46 14 32 26 48 25 38 35 25 47 18 36 26 45 15 32 26 45 12 28 32 45 -2 26 34 42 1 28 36 48 4 32 27 so 23 38 36 26 46 14 33 30 47 15 34 20 43 2 27 28 43 7 27 34 42 10 30 40 53 10 34 32 51 25 39 36 27 43 10 32 31 49 14 34 20 45 0 25 19 40 5 29 39 41 9 29 32 45 19 34 27 54 27 40 37 28 43 8 32 33 48 14 33 28 45 2 24 20 45 -8 29 38 40 5 27 24 45 22 34 27 54 24 40 33 29 49 6 32 33 48 11 30 27 45 -2 23 28 44 -8 29 42 0 0 0 0 47 20 34 32 58 29 41 35 30 49 2 30 30 30 5 28 28 42 -2 24 38 43 -4 28 40 0 0 0 0 44 14 33 26 60 29 41 37 31 46 2 30 30 0 0 0 0 44 -6 25 42 43 7 28 37 0 0 0 0 48 19 35 16 0 0 0 0 J TABLE A-1 l LOWER BRADLEY RIVER FLOWS AND OBSERVATIONS DURING THE STUDY PERIOD Date Q 1 1 /1 3 99.8 11/20 12/18 91 • 1 3/8 62.7 3/24 68.3 Location/Notes Near Tree Bar Cross Section 2 Significant Tidal/storm surge effect on USGS gage area crested at 1245. USGS gage reading at 1210 was 0.7 ft (tidally affected). Seldovia high tide was forecast to be 20.3 ft at 1105. Near Tree Bar Cross Section 2 Near Tree Bar Cross Section 2 Near Tree Bar Cross Section 2 TABLE A-2 STAGE DISCHARGE AND TEMPERATURE AT NORTH FORK BRADLEY RIVER DATE DECEMBER JANUARY FEBRUARY STAGE AVERAGE STAGE AVERAGE STAGE AVERAGE COLLECTED ADJUSTED 0 TEMP COLLECTED ADJUSTED 0 TEMP COLLECTED ADJUSTED 0 TEMP . 25.8 88.1 2.3 25.6 25'.6 86.7 2.9 2 20.9 20.9 56.9 2.0 22.3 22.3 64.9 3.4 3 13.9 13.9 26.6 2.4 20.2 21).2 53.2 3.1 4 1 o. 7 10.7 17.5 2.4 18.8 1 e.8 46.2 2.4 5 8.8 8.8 13.2 2.1 1 7.1 17. 1 38.6 2.4 6 7.9 7.9 11.4 2.1 14.3 14.3 28.0 1 .6 7 9.8 9.8 15.3 2.8 17.6 13.5 25.3 1.9 8 11.1 11.1 18.5 2.9 21.4 13.0 23.8 1.8 9 9.8 9.8 15.3 2.9 26.6 12.8 23.2 1.9 10 18.3 18.3 43.9 2.9 35.8 12.6 22.6 1.8 11 15.1 15.1 30.8 2.6 40.1 12.5 22.3 1.6 12 10.8 10.8 17.7 2.0 47.8 12.4 22.0 1.8 13 9.3 9.3 14.2 1.8 55.5 ll.3 21.7 1.5 14 7.8 7.8 11.2 2.0 48.1 1 :L 1 21.2 1.8 15 6.8 6.8 9.5 2.4 . 48.5 11.9 20.6 1.9 16 6.3 6.3 8.7 2.3 48.4 11.7 20.1 1 .8 17 9.3 9.3 14.2 2.9 46.0 11.5 19.5 1.6 18 9.8 9.8 15.3 3.0 33.1 11.3 19.0 1.8 19 16.4 16.4 35.7 2.0 7.9 7.9 11.4 3.1 17.2 11.2 18.7 1.9 20 16.1 16.1 34.5 2.0 9.9 9.9 15.6 3.0 11 • 1 11 • 1 18.5 2.0 21 18.2 18.2 43.4 2.1 7.8 7.8 11.2 2.9 10.8 1('.8 17.7 2.0 22 16.5 16.5 36.1 2.5 6.7 6.7 9.3 2.6 10.5 1 !).5 17 .o 2.0 23 16.0 16.0 34.1 2.8 6.2 6.2 8.5 2.6 10.4 ~0.4 16.7 2.0 24 14.7 14. 7. 29.4 2.0 6.0 6.0 8.2 2.4 10.3 10.3 16.5 2.0 25 16.1 16.1 34.5 2.1 5.0 5.0 6.8 2.3 9.6 ~·.6 14.9 2.0 26 14.5 14.5 28.7 2.0 4.7 4.7 6.5 2.6 10.0 j 0.0 15.8 2.0 27 17.1 14.4 28.3 2.0 6.5 6.5 9.0 3.5 9.7 10.0 15.8 2.0 28 26.2 14.3 28.0 2.0 6.4 6.4 8.9 3.5 '::1.7 15.1 2.0 29 20.6 14.2 27.6 2.0 7.6 7.6 10.9 3.5 30 17.5 17.5 40.3 2.0 19.6 19.6 50.1 3.3 31 23.4 23.4 71.7 2.0 32.3 32.3 145.0 3.0 AVERAGE 17.9 16.3 36.3 2.1 10.9 10.9 23.5 2.6 24.9 n.2 26.6 2.0 TABLE A-3 J DATE MARCH APRIL MAY STAGE AVERAGE STAGE AVERAGE STAGE AVERAGE COLLECTED ADJUSTED 0 TEMP COLLECTED ~OJUSTED 0 TEMP COLLECTED ADJUSTED 0 TEMP 9.4 9.4 14.4 2.0 7.1 7.1 10.0 ---7.4 7.4 10.5 1.5 2 9.6 9.6 14.9 2.0 8.5 7.0 9.8 ---7.8 7.6 11.2 1 .5 3 9.6 9.6 14.9 1 • 9 8.2 6.7 9.3 4 9.2 9.2 14.0 2.0 6.2 6.2 8.5 5 9.2 9.2 13.8 2.0 5.8 5.8 7.9 6 9.1 9.1 14.0 2.0 6.2 6.2 8.5 0.4 7 9.2 9.2 2.0 8.3 8.3 12.2 1.3 8 7.6 7.6 1 o. 9 1.4 9 6.5 6.5 9.0 10 7.2 6.5 9.0 11 1 o. 1 6.6 9.2 1 2 12.2 6.7 9.3 13 9.0 6.8 9.5 14 7.5 6.9 9.7 0.8 15 7.0 7.0 9.8 1.4 16 7.8 7.8 11 • 2 1.5 17 7.3 7.3 10.3 1.5 18 6.5 6.5 9.0 1.5 19 6.3 6.3 8.7 1 • 1 20 7.0 7.0 9.8 1.6 21 9.8 9.8 15.3 1 • 5 6.3 6.3 8.7 1.6 22 9.8 9.8 15.3 1.8 6.3 6.3 8.7 1.6 23 8.7 8.7 13.0 1.5 6.3 6.3 8.7 1.6 24 8.3 8.3 12.2 1.4 6.3 6.3 8.7 1.6 25 8.1 8.1 11.8 1.0 6.7 6.7 9.3 1 .5 26 7.7 7.7 1 1.1 1.0 7.9 7.9 11.4 1.5 27 7.7 7.7 1 1 • 1 0.3 7.0 7.0 9.8 1.5 28 8.0 8.0 11 • 6 0.1 7.0 7.0 9.8 1.6 29 9.6 7.9 11.4 1.0 7.4 7.4 10.5 1.5 30 .9.1 7.7 11 . 1 0.1 7.4 7.4 10.5 1.5 31 9.8 7.4 10.5 AVERAGE 9.0 8.7 13.0 1.4 7.4 6.8 9.6 1.4 7.6 7.'.. 10.9 1.5 CONTINUED TABLE A-3 PROVISIONAL DISCHARGE DATA FOR BRADLEY RIVER AT THE OUTLET OF BRADLEY LAKE 1984 WY UNITED STATES DEPARTMENT OF INTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15239000 Bradley Lake near Horner, AK PROCESS DATE: 08-MAY-85 09:16 GLP LAT 594520 LONG 15051 00 STATE 02 COUNTY 120 DATUM OF GAGE: 1050.00 FT NGVD DRAINAGE AREA 56.1 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1983 TO SEPTEMBER 1984 ME.>\N VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 445 154 972 58 60 so 96 94 347 1140 699 454 2 455 155 685 56 60 50 91 104 369 1030 723 410 3 449 166 509 56 60 51 88 112 397 941 756 381 4 414 169 404 56 60 55 85 117 430 900 831 366 5 381 164 337 54 60 56 83 122 466 963 930 354 6 352 157 283 54 58 58 80 124 479 1020 953 344 7 318 165 244 54 58 60 78 126 484 1080 951 338 8 284 399 215 52 58 67 78 131 494 1100 911 346 9 271 464 191 52 56 90 76 140 496 1080 890 368 10 281 457 173 52 56 167 73 154 491 1030 884 386 11 354 418 163 60 56 256 72 174 482 977 875 400 12 397 360 150 120 56 298 71 192 486 956 852 414 13 385 305 136 300 56 300 70 208 518 919 827 422 14 367 264 123 200 58 283 69 221 572 880 784 523 15 338 248 115 150 58 260 69 230 590 838 747 940 16 318 226 108 100 61 237 69 237 602 801 738 1240 17 333 207 100 80 63 216 68 246 588 775 735 1190 18 337 186 94 70 62 196 67 278 578 748 828 1020 19 320 166 90 60 61 180 66 327 562 728 1850 876 20 306 147 87 60 59 167 65 365 557 707 2300 761 21 305 205 83 58 61 153 64 386 570 714 1940 655 22 302 255 78 58 59 140 64 399 576 741 1610 569 23 283 256 74 58 58 130 66 403 605 772 1440 500 24 257 239 71 58 56 120 67 406 710 781 1280 464 25 232 221 70 58 55 114 66 398 1120 767 1270 475 26 214 209 68 58 53 111 67 388 1540 756 1190 535 27 199 193 66 58 52 109 66 371 1540 733 1000 547 28 190 244 65 58 51 104 69 356 1380 722 831 545 29 183 985 63 60 so 102 74 353 1250 709 693 566 30 172 1380 61 60 ---97 83 355 1200 686 587 634 31 162 ---60 60 ---98 ---351 ---685 509 --- TOTAL 9604 9164 5938 2388 1671 4375 2200 7868 20479 26679 31414 17023 MEAN 310 305 192 77.0 57.6 141 73.3 254 683 861 1013 567 MAX 455 1380 972 300 63 300 96 406 1540 1140 2300 1240 MIN 162 147 60 52 so so 64 94 347 685 509 338 AC-FT 19050 18180 11780 4740 3310 8680 4360 15610 40620 52920 62310 33770 CAL YR 1983 TOTAL 129447 MEAN 355 MAX 1380 MIN 42 AC-FT 25680C WTR YR 1984 TOTAL 138803 MEAN 379 MAX 2300 MIN 50 AC-FT 275300 TABLE A-4 1985 WY UNITED STATES DEPARTMENT OF INTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15239000 Bradley Lake near Homer, AK PROCESS DATE: 08-MAY-85 11:-13 JAT LAT 594520 LONG 1505100 STATE 02 COUNTY 120 DATUN OF GAGE: 1050.00 FT NGVD DRAINAGE AREA 56.1 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1984 TO SEPTEMBER 1985 MfAN VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 989 140 77 116 277 109 55 i I 2 1130 131 73 168 257 98 54 I 3 1050 1 21 73 177 232 92 53 I 4 881 118 92 172 208 87 52 5 730 114 137 163 187 86 51 6 733 112 161 151 164 83 49 7 748 106 161 154 144 82 49 8 673 99 155 166 132 81 49 9 585 94 145 171 1 21 80 48 10 504 90 136 198 110 86 48 11 438 84 123 227 90 86 47 12 387 80 116 219 80 82 45 13 343 77 107 202 70 79 45 14 307 75 98 189 60 76 47 15 274 76 94 173 so 71 49 16 249 74 89 167 40 70 51 17 230 72 86 185 36 72 51 18 211 71 84 198 34 75 so 19 196 70 80 194 32 75 so 20 183 75 77 217 30 81 so 21 173 91 74 213 136 81 49 22 196 94 73 206 137 78 48 23 227 94 72 199 138 77 47 24 222 92 69 191 139 73 25 208 90 68 178 135 71 26 194 87 66 166 136 68 27 186 85 64 168 120 65 28 173 82 63 159 111 64 29 165 79 64 165 ---61 30 158 78 68 194 ---59 31 145 ---81 272 ---57 TOTAL 12888 2751 2926 5718 3406 2405 MEAN 416 91.7 94.4 184 122 77.6 MAX 1130 140 161 272 277 109 MIN 145 70 63 116 30 57 AC-FT 25560 5460 5800 11340 6760 4770 CAL YR 1984 TOTAL 132662 MEAN 362 MAX 2300 MIN so AC-FT 263100 CONTINUED TABLE A-4 PROVISIONAL DISCHARGE FOR THE LOWER BRADLEY RIVER NEAR TIDEWATEB 1984 WY UNITED STATES DEPARTMENT OF INTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15239070 Bradley River near Tidewater near Homer, AK PROCESS DATE: 08-MAY-85 09:16 GLP LAT.594806 LONG 1505258 STATE 02 COUNTY 120 DATUM OF GAGE: DRAINAGE AREA 82.0 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1983 TO SEPTEMBER 1984 MEAN VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 520 180 1380 66 68 60 120 155 464 1600 931 568 2 540 180 958 64 68 60 120 160 519 1500 966 505 3 520 200 640 64 68 60 110 165 567 1400 1030 468 4 480 200 500 64 68 64 110 165 608 13CO 1140 448 5 440. 190 420 62 68 68 110 165 662 1400 1300 429 6 410 180 370 62 66 72 100 170 678 1450 1280 411 7 370 230 310 62 66 76 100 173 *8* 1500 1260 407 8 340 500 270 62 66 82 100 188 702 1600 1190 426 9 330 626 240 62 66 100 95 212 702 1500 1170 456 10 350 590 220 62 66 200 90 242 712 1400 1160 476 11 430 534 200 62 66 300 90 267 687 1350 1170 488 12 460 481 180 180 66 350 86 282 707 1300 1110 496 13 450 410 160 400 66 340 88 303 782 1250 1070 529 14 430 380 160 280 68 310 90 328 835 1200 1010 901 15 390 350 150 180 70 290 88 328 853 1150 950 1590 16 370 330 147 130 70 260 86 328 847 11CO 937 1650 17 390 300 137 96 72 240 86 341 810 1100 954 1440 18 400 280 120 86 70 220 83 395 804 1050 1140 1220 19 370 260 111 74 68 200 81 455 778 1000 2830 1080 20 358 240 :106 68 68 190 81 496 778 980 3070 922 21 358 320 106 68 68 170 86 516 820 lOCO 2490 775 22 350 382 102 68 66 160 96 542 847 1050 2220 669 23 330 361 96 68 64 150 83 554 925 11CO 1960 600 24 300 325 9{) 68 64 140 79 567 1130 1050 1800 608 25 270 306 86 68 62 140 77 563 1700 1010 1840 682 26 250 261 84 70 62 130 81 533 2100 10(0 1650 692 27 230 236 80 70 60 130 86 492 2000 966 1360 678 28 220 903 76 70 60 130 102 472 1900 943 1110 702 29 210 2400 74 70 60 130 120 480 1800 926 910 809 30 200 2280 70 70 ---120 140 476 1700 892 754 925 31 190 ---68 70 ---120 ---460 ---903 646 TOTAL 11256 14415 7711 2946 1920 5062 2864 10973 29100 36970 42408 22050 MEAN 363 481 249 95.0 66.2 163 95.5 354 970 1193 1368 735 MAX 540 2400 1380 400 72 350 140 567 2100 16CO 3070 1650 MIN 190 180 68 62 60 60 77 155 464 892 646 407 AC-FT 22330 28590 15290 5840 3810 10040 5680 21760 57720 73330 84120 43740 WTR YR 1984 TOTAL 187675 MEAN 513 MAX 3070 MIN 60 AC-FT 3723(;0 TABLE A-5 1985 WY UNITED STATES DEPARTMENT OF ,NTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15239070 Bradley River near Tidewater near Homer, AK PROCESS DATE: 21-MAY-8!> 09:50 AM LAT 594806 LONG 1505258 STATE 02 COUNTY 120 DATUM OF GAGE: DRAINAGE AREA 82.0 PROVISIONAL DATA DISCHARGE, IN CUBIC FEE"I PER SECOND, WATER YEAR OCTOBER 1984 TO SEPTEMBER 1985 MEAN 'J.ALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 1440 188 98 287 376 50 65 2 1580 167 94 303 335 50 60 I I 3 1430 165 96 245 300 55 60 4 1170 160 161 217 261 60 57 5 968 162 227 201 242 70 59 6 1020 157 217 185 220 96 52 7 1030 150 204 207 180 92 50 8 933 142 191 228 150 73 50 9 805 125 175 231 120 77 48 10 68~ 125 162 337 100 55 49 11 586 120 152 328 80 84 45 12 509 104 142 282 65 86 45 13 446 98 137 250 55 85 40 14 397 106 130 236 45 80 36 15 355 106 120 207 35 80 29 16 325 104 115 196 35 75 30 17 300 98 106 249 35 73 38 18 276 94 106 267 35 71 39 19 261 92 102 239 38 66 44 20 242 122 100 282 40 84 46 21 231 152 95 261 40 84 46 22 284 135 93 247 40 84 44 23 294 127 88 234 45 81 46 24 279 120 84 231 45 77 25 258 113 84 212 so 81 26 242 111 81 191 60 79 27 234 108 80 204 60 73 28 220 106 75 193 55 70 29 217 100 75 212 ---68 30 215 98 150 -I 0 ---68 31 204 ---157 469 ---65 TOTAL 17440 3755 3897 7747 3142 2292 MEAN 563 125 126· 250 11 2 73.9 MAX 1580 188 227 469 376 96 MIN 204 92 75 185 35 50 AC-FT 34590 7450 7730 15370 6230 4550 CAL YR 1984 TOTAL 179385 MEAN 490 MAX 3070 MIN 60 AC-FT 355800 CONTINUED TABLE A-5 PROVISIONAL USGS DISCHARGE FOR THE MIDDLE FORK BRADLEY RIVER AT DIVERSION 1984 WY UNITED STATES DEPARTMENT OF INTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15239050 Bradley River Trib near Homer, AK PROCESS DATE: 08-MAY-85 09:16 GLP LAT 594642 LONG 1504515 STATE 02 COUNTY 120 DATUM or GAGE: 2300.00 FT NGVD DRAINAGE AREA 9.25 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1983 TO SEPTEMBER 1984 11EAN VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 47 12 18 5.8 4.4 3.4 3.8 4.7 20 149 130 62 2 41 12 10 5.8 4.4 3.4 3.8 4.5 27 127 141 57 3 38 14 9.8 5.8 4.4 3.4 3.8 4.5 33 120 152 57 4 34 15 9.6 5.8 4.4 3.6 3.8 4.ft 38 lZ7 178 55 5 31 15 9.4 5.8 4.3 4.0 3.8 4.4 itO 152 189 53 6 29 13 9.2 5.8 4.2 4.0 3.8 4.5 37 '62 168 50 7 27 16 9.0 5.4 4.2 4.0 3.8 4.7 40 165 155 50 8 27 35 8.5 5.4 4.0 4.5 3.8 5.3 45 162 146 60 9 33 16 8.0 5.4 ft.O 5.0 3.8 6.0 47 162 149 65 10 ft3 29 8.0 6.0 4.0 8.0 3.6 7.ft 49 ''49 141 65 11 65 20 7.5 10 4.0 6.0 3.6 8.0 47 1'+9 146 62 12 51 19 7.5 15 3.8 5.3 3.8 9.0 so ·: l9 144 57 13 43 13 7.0 11 3.8 4.9 3.8 9.3 65 '135 135 63 14 38 14 7.0 8.0 3.8 4.9 3.8 9.8 68 132 125 158 15 35 13 7.0 6.0 3.8 4.7 3.8 9.8 63 :27 122 207 16 34 12 6.5 5.3 3.8 4.5 3.8 9.5 62 i30 125 133 17 33 12 6.5 5.8 3.8 4.4 3.8 10 58 130 132 102 18 30 11 6.5 5.8 3.8 4.4 3.8 12 63 35 192 96 19 28 11 6.5 5.6 3.6 4.4 3.8 14 67 138 460 94 20 26 10 6.5 5.4 3.6 4.4 3.8 15 70 138 281 78 21 25 15 6.2 5.4 3.6 4.2 3.8 16 82 149 216 65 22 25 20 6.2 s.o 3.6 4.2 4.0 16 94 i65 245 57 23 22 16 6.2 4.8 3.6 4.2 3.8 18 110 165 194 53 24 20 12 6.2 4.6 3.6 4.2 3.8 18 152 1~6 208 62 25 18 10 6.2 4.6 3.6 ft.2 3.8 18 231 130 263 79 26 18 10 6.0 4.6 3.6 4.0 4.0 17 208 ·: 25 190 63 27 16 10 6.0 4.6 3.4 4.0 4.2 16 162 120 136 55 28 16 45 6.0 ft.6 3.4 4.0 4.9 17 144 115 108 67 29 14 110 6.0 4.6 3.4 5.0 4.9 20 178 : i 2 94 84 30 14 30 6.0 4.6 ---4.0 4.7 20 185 15 79 96 31 12 ---6.0 4.6 ---ft.O ---18 ---'25 70 TOTAL 933 586 235.0 187.ft 111.8 137.2 117.5 350.8 2535 ft:l05 5214 2305 MEAN 30.1 19.5 7.58 6.05 3.86 4.43 3.92 11.3 84.5 139 168 76.8 MAX 65 110 18 15 4.ft 8.0 4.9 20 231 165 460 207 MIN 1l 10 6.0 4.6 3.4 3.4 3.6 4.ft 20 .12 70 so CFSM 3.25 2.11 .82 .65 .42 .48 .42 1.22 9.14 l:i.O 18.2 8.30 IN. 3.75 2.36 .95 .75 .45 .55 .47 1. 41 l 0.19 17.31 20.97 9.27 AC-FT 1850 1160 466 372 222 272 233 696 5030 8S40 10340 4570 WTR YR 1984 TOTAL 17017.7 MEAN 46.5 MAX 460 MIN 3.4 CFSM 5.03 IN. 68.44 AC-FT 33750 TABLE A-6 1985 WY UNITED STATES DEPARTMENT OF INTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15239050 Bradley River Trib near Homer, AK PROCESS DATE: 08-MAY-85 09:16 GLP LAT 594642 -LONG 1504515 STATE 02 COUNTY 120 DATUM OF GAGEc 2300.00 FT NGVD DRAINAGE AREA 9.25 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1984 TO SEPTEMBER 1985 MfAN VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 159 9.0 4.6 4.8 4.5 3.5 3.0 2 127 8.0 4.6 4.6 4.0 3.5 3.0 3 92 7.0 4.6 4.4 3.8 3.5 3.0 4 70 6.6 5.8 4.4 3.8 3.5 3.0 5 60 6.2 4.3 4.2 3.8 3.5 3.0 6 90 5.6 4.6 4.2 3.8 3.5 3.0 7 86 5.4 4.6 4.0 3.8 3.5 3.0 8 72 5.2 4.4 4.0 3.8 3.5 3.0 9 58 4.8 4.4 4.0 3.8 3.5 3.0 10 so 4.8 4.4 4.0 3.8 3.5 3.0 11 45 4.6 4.4 4.0 3.8 3.3 2.9 12 40 4.6 4.3 4.0 3.8 3.3 2.9 13 36 4.6 4.3 3.9 3.8 3.3 2.9 14 34 4.6 4.3 3.8 3.8 3.3 2.9 15 32 4.6 4.3 3.8 3.8 3.3 2.9 16 29 4.6 4.3 3.8 3.8 3.3 2.9 17 27 4.6 4.3 4.0 3.8 3.3 2.9 18 25 4.6 4.2 4.2 3.7 3.3 2.9 19 24 4.8 4.2 4.2 3.7 3.3 2.9 20 23 5.0 4.2 4.0 3.7 3.2 2.9 21 23 6.0 4.2 4.0 3.7 3.2 2.9 22 30 5.4 4.2 3.9 3.7 3.2 2.8 23 26 4.8 4.2 3.9 3.7 3.2 2.8 24 23 4.8 4.2 3.8 3.7 3.2 2.8 25 20 4.8 4.2 3.8 3.7 3.2 26 18 4.8 4. 1 3.8 3.7 3.2 27 16 4.7 4.1 3.8 3.7 3.2 28 14 4.7 4. 1 3.8 3.6 3.2 29 12 4.7 4.1 3.8 ---3.2 30 11 4.7 5.0 4.5 ---3. 1 31 10 ---6.0 5.0 ---3.0 TOTAL 1382 158.6 138.0 126.4 106.1 102.8 MEAN 44.6 5.29 4.45 4.08 3.79 3.32 MAX 159 9.0 6.0 5.0 4.5 3.5 MIN 10 4.6 4.1 3.8 3.6 3.0 CFSM 4.82 .57 .48 .44 .41 .36 IN. 5.56 .64 .55 .51 .43 .41 AC-FT 2740 315 274 251 210 204 CAL YR 1984 TOTAL 16942.3 MEAN 46.3 MAX 460 MIN 3.4 CFSM 5.01 IN. 68.14 AC-FT ::.3610 CONTINUED TABLE A-6 PROVISIONAL USGS DISCHARGE DATA FOR UPPER BRADLEY RIVER 1984 WY UNITED STATES DEPARTMENT OF INTEt~iOR -GEOLOGICAL SURVEY .:. WATER RESOURCES DIVISION 15238990 Upper Bradley River near Homer, AK PROCESS DATE: 08-May-85 09:16 CLP LAT 594215 LONG 1504215 STATE 02 COUNTY 1 20 DATUM OF CAGE: 1200.00 FT NGVD DRAINAGE AREA: 10.0 PROVISIONAL DATA DISCHARGE, IN CUBIC FEr:T PER SECOND, WATER YEAR OCTOBER 1983 TO SEPTEMBER 1984 I~EAN VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 90 14 30 1.0 .80 .60 1.0 3.0 71 1 :6 128 48 2 86 15 20 1.0 .90 .60 1.0 4.0 92 1' I} 145 47 3 60 17 15 1.0 .80 .60 1.0 5.0 94 109 170 58 4 43 17 10 .80 .80 .80 1.0 6.0 125 1 ;,s 255 56 5 38 16 10 .80 .80 1.0 1.0 8.0 109 191 229 51 6 37 15 9.0 .80 .so 2.0 1.0 10 92 2'9 209 45 7 25 45 8.0 .80 .80 5.0 1.0 11 88 2:14 182 50 8 18 135 7.0 .80 .80 15 1.0 13 88 1'!5 166 67 9 23 35 6.0 1.5 .80 25 1.0 15 80 H2 191 67 10 81 40 5.0 3.0 .80 30 1.0 22 71 170 162 76 11 128 25 4.0 10 .80 40 1 .0 30 76 1 bO 162 73 12 65 19 3.0 30 .80 25 1.0 36 90 11;0 166 65 13 48 15 2.0 10 .80 15 1. 0 38 120 1SO 145 102 14 39 13 1. 5 5.0 .80 8.0 1.0 38 100 lL.O 128 325 15 33 11 1.5 1.5 .80 5.0 1.0 37 109 1 : 0 131 325 16 38 10 1.5 1.0 .80 4.0 1.0 39 98 130 131 172 17 80 9.0 1.5 1.0 .80 3.0 1.0 53 92 1b0 142 115 18 42 8.0 1.5 1.0 .80 2.0 1.0 78 88 11.0 541 107 19 31 7.0 1.5 1.0 .60 2.0 1.0 92 88 150 1590 90 20 32 7.0 1.5 1.0 .60 2.0 1.0 82 98 1SO 540 65 21 40 15 1.5 1.0 .60 1.5 1.0 73 98 1 :,o 295 53 22 31 20 1.5 1.0 .60 1.5 1.0 69 98 160 382 47 23 25 14 1 .5 1.0 .60 1.5 1.0 65 136 HO 287 62 24 23 10 1.5 1.0 .60 1.5 1.0 62 213 1FO 345 100 25 21 7,0 1.5 1.0 .60 1.5 1.0 58 431 DO 375 120 26 19 6.0 1.5 1.0 .60 1.5 1.0 51 270 liB 246 90 27 18 6.0 1.5 1.0 .60 1.5 1.0 47 179 1 ;~a 137 86 28 16 100 1.5 1.0 .60 1.5 1.5 47 162 1:'1 96 1 OS 29 15 300 1.5 1.0 .60 1.0 2.0 56 170 114 71 125 30 14 50 1.5 1.0 ---1.0 2.5 53 162 1'14 60 170 31 14 ---1.5 1.0 ---1.0 ---53 ---122 50 TOTAL 1253 1001 .. 0 156.0 84.00 21.00 201.60 33.0 1254.0 1788 46'12 7857 2962 MEAN 40.4 33.4 5.03 2. 71 .72 6.50 1.10 40.5 126 El 253 98.7 MAX 128 300 30 30 .80 40 2.5 92 431 224 1590 325 MIN 14 6.0 1.5 .80 .60 .60 1.0 3.0 71 1 09 50 45 AC-FT 2490 1990 309 167 42 400 65 2490 109 :.o 45 WTR YR 1984 TOTAL 23282.6 MEAN 63.6 MAX 1590 MIN .60 AC-FT 46180 TABLE A-7 DAY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 TOTAL MEAN MAX MIN AC-FT OCT 245 171 110 76 69 141 89 64 44 35 31 27 23 21 23 19 16 17 15 14 14 62 .48 28 35 56 14 1985 WY 15238990 LAT 594215 NOV 8.8 8.3 7.1 6.8 7.7 7.4 7.1 8.7 6.0 3.3 3.1 3.3 3.1 4.4 23 14 9.7 6.8 5.7 4.7 4.1 3.5 UNITED STATES DEPARTMENT OF INTE!iiOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION Upper Bradley River near Homer, AK PROCESS DATE: 08-May-8!' 10:54 JAT LONG 1504215 STATE 02 COUNTY 120 DATUM OF GAGE: 1200.00 FT NGVD DRAINAGE AREA: 10.0 PROVISIONAL DATA DEC 4.4 23 34 25 14 10 7.1 5.7 4.7 3.9 3.5 3. 1 15 DISCHARGE, IN CUBIC FE:::T PER SECOND, WATER YEAR OCTOBER 1984 TO SEPTEMBER 1985 HEAN VALUES JAN FEB MAR APR MAY JUN 27 42 47 15 30 9.1 16 6.8 11 7.7 8.0 39 5.7 5.8 15 4.1 15 3.5 17 28 23 12 8.0 6.3 6.0 9.0 14 13 21 22 16 1 2 9.3 7.4 6.0 6.8 7.7 12 19 50 503.2 16.2 so 6.0 998 Jl;L AUG SEP CONTINUED TABLE A-7 PROVISIONAL USGS DISCHARGE Dt\TA FOR BARBARA CREEK NEAR SELDOVIA 1984 WY UNITED STATES DEPARTMENT OF INTERIOR -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15238820 Barbara Creek near Seldovia, AK PROCESS DATE: 08-May-85 09:16 GLP LAT 592890 LONG 1513842 STATE 02 COUNTY 120 DATUM OF GAGE: 40.00 FT NGVD DRAINAGE AREA: 20.7 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1983 TO SEPTEMBER 1984 M.:AN VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 43 53 798 30 40 33 48 60 138 194 60 94 2 47 53 497 32 40 32 47 59 154 172 55 85 3 53 59 286 32 39 33 46 57 168 154 53 78 4 so 56 191 30 39 40 45 59 190 154 52 71 5 49 53 154 30 35 43 46 56 211 156 51 66 6 48 51 113 30 38 45 45 54 216 157 so 62 7 46 147 94 30 38 45 45 55 224 162 48 60 8 45 331 81 30 38 47 45 60 216 161 46 59 9 46 212 74 33 37 69 44 64 213 148 45 56 10 51 179 69 38 37 98 43 71 207 144 45 53 11 59 157 64 43 38 98 43 78 204 141 51 50 12 64 135 59 784 38 89 43 83 211 129 45 50 13 62 115 50 726 40 89 43 87 235 1 21 43 56 14 61 103 40 364 40 71 43 91 239 112 43 117 15 60 91 33 225 41 65 43 89 245 100 41 154 16 59 83 33 165 43 62 42 89 242 96 40 141 17 62 78 33 130 43 60 41 1PO 225 96 40 124 18 61 69 32 100 42 57 40 124 212 91 66 110 19 59 62 32 80 40 55 40 144 207 89 298 112 20 60 71 32 60 40 53 40 151 207 89 191 110 21 68 218 32 45 40 52 39 155 219 88 144 100 22 71 155 32 40 39 51 38 151 216 89 193 89 23 69 138 31 38 39 50 38 147 232 83 158 89 24 65 124 31 38 38 48 38 151 283 80 171 87 25 62 113 31 38 37 47 38 154 350 74 179 87 26 60 98 31 38 36 48 39 154 315 71 154 81 27 59 88 31 38 35 49 42 146 266 72 144 81 28 57 400 30 38 34 49 46 138 224 70 135 91 29 56 1700 30 40 34 50 50 141 230 66 115 111 30 54 1100 30 40 ---48 54 141 218 64 109 174 31 53 ---30 40 ---48 ---138 ---60 100 TOTAL 1759 6292 3104 3426 11 21 1724 1294 3247 6717 3483 2965 2708 MEAN 56.7 210 100 111 38.7 55.6 43.1 105 224 112 95.6 90.3 MAX 71 1700 798 784 43 98 54 155 350 194 298 174 MIN 43 51 30 30 34 32 38 54 138 60 40 so CFSM 2.74 10.1 4.83 5.36 1.87 2.69 2.08 5.07 10.8 5.41 4.62 4.36 IN. 3.16 11 . 31 5.58 6.16 2.01 3.10 2.33 5.84 12.07 6.26 5.33 4.87 AC-FT 3490 12480 6160 6800 2220 3420 2570 6440 13320 6910 5880 5370 WTR YR 1984 TOTAL 37840 MEAN 103 MAX 1700 Ml1·l 30 CFSM 4.98 IN. 68.00 AC-FT 75060 TABLE A-8 1985 WY UNITED STATES DEPARTMENT OF INTEKitm -GEOLOGICAL SURVEY -WATER RESOURCES DIVISION 15238820 Barbara Creek near Seldovia, AK PROCESS DATE: 08-May-85 10:52 JAT LAT 592890 LONG 1513842 STATE 02 COUNTY 120 DATUM OF GAGE: 40.00 FT NGVD DRAINAGE AREA: 20.7 PROVISIONAL DATA DISCHARGE, IN CUBIC FEET PER SECOND, WATER YEAR OCTOBER 1984 TO SEPTEMBER 1985 ME1\N VALUES DAY OCT NOV DEC JAN FEB MAR APR MAY JUN JUL AUG SEP 1 366 55 45 304 311 235 53 2 374 so 47 211 251 211 78 3 360 42 47 169 211 194 64 4 329 42 123 135 182 190 57 5 329 52 105 105 157 179 53 6 394 49 39 96 126 171 54 7 401 48 75 113 108 164 48 8 426 45 69 132 108 111 45 9 371 38 64 113 100 35 45 10 329 38 59 254 185 43 45 11 294 49 57 208 175 37 45 12 255 107 54 153 406 34 35 13 216 110 52 135 ---33 44 14 190 154 51 1 21 ---32 47 15 169 108 47 108 ---32 49 16 154 48 44 103 ---32 49 17 135 44 47 153 ---31 45 18 124 43 53 154 ---31 32 19 113 44 53 124 ---31 28 20 105 83 45 138 960 31 27 21 96 124 44 121 749 31 27 22 109 75 45 108 600 32 27 23 91 65 47 105 564 31 27 24 81 59 45 96 422 30 25 76 54 44 83 361 29 26 69 44 43 81 413 29 27 65 46 40 115 340 29 28 60 44 53 100 231 30 29 60 47 57 113 ---28 30 60 46 116 210 ---29 31 59 ---194 424 ---38 TOTAL 6263 1861 1955 4633 ---2193 MEAN 202 62.1 63.1 149 ---70.7 MAX 426 154 194 424 ---235 MIN 59 38 40 81 ---28 CFSM 9.76 3.00 3.05 7.20 ---3.42 IN. 11.26 3.35 3.51 8.33 ---3.94 AC-FT 12420 3700 3880 9190 ---4350 CONTINUED CAL YR 1984 TOTAL 36766 MEAN 100 MAX 784 MIN 30 CFSM 4.83 IN. 66.07 AC-FT 72930 --·----' TABLE A-8 ' APPENDIX B Table No. Table B-1 Table B-2 D-BL-108 APPENDIX B WATER TEMPERATURE DATA, DECEMBER 1984-MAY 1985 Title Surface and Intragravel Water Temperatures in Tree Bar Reach Surface and Intragravel Water Temperatures in Riffle Reach DATE DECEMBER SURFACE WATER I I MIN MAX MEAN MIN I 1 2 3 4 5 6 7 8 9 0.6 1.2 0.9 1.5 10 0.5 1 • 1 0.9 1.2 11 0.3 0.9 0.5 0.7 12 0.2 0.9 0.6 0.6 13 -.1 0.4 0.1 0.4 14 -. 1 0.0 -.1 0.1 15 -.1 0.7 o.o -.1 16 0.7 1.0 0.9 0.2 17 1.0 1.6 1.4 0.7 18 1.6 1.8 1.8 1.3 19 0.3 1.9 1.4 1.5 20 -. 1 0.3 -.1 0.4 21 -.1 1.2 0.4 0.2 22 1.2 1.5 1 .4 0.6 23 0.9 1.8 1.6 1.3 24 0.0 0.9 0.2 0.4 25 0.0 1.0 0.5 0.4 26 -.1 1.0 0.3 0.3 27 -.1 0.0 -.1 0.1 28 . -.1 0.0 -.1 0.1 29 -.1 0.0 -.1 0.1 30 -.1 0.1 -.1 0.1 31 o. 1 0.8 0.5 0.2 AVERAGE 0.3 0.9 0.6 0.5 SURFACE AND INTRA GRAVEL WATER TEMPERATURES IN TREE BAR REACH JANUARY INTRACRAVEL WATER SURFACE WATER lNTRAGRAVEL WATER MAX MEAN MIN MAX MEAN MIN MAX MEAN MIN 0.6 1.2 1.0 0.5 1.0 0.8 0.8 0.5 0.8 0.6 0.8 1.0 0.9 1.2 0.5 1.1 0.9 0.8 1.0 0.9 0.8 0.5 1 • 1 0.9 1.0 1.1 1.1 0.5 0.1 1.0 0.6 0.9 1.1 1. 1 o. 1 0.2 1.1 0.7 0.7 0.9 0.9 -.1 0.9 1.5 1.3 0.9 1.3 1.1 -.1 0.7 1.5 1.2 1.2 1.4 1.3 -.1 1.7 1.6 0.9 1.3 1. 1 1.3 1.4 1.3 -.1 1.5 1.3 1.0 1.5 1.2 1.3 1.4 1.3 -.1 1.2 1.0 1.0 1.3 1.2 1.4 1.5 1.4 -.1 0.8 0.8 0.1 1.0 0.6 1.1 1.5 1.3 -.1 0.6 0.6 0.2 0.9 0.6 0.9 1.1 1.0 -.1 0.4 0.2 0.4 0.9 0.7 0.9 1.0 0.9 -.1 0.2 0.0 0.7 1.0 0.9 0.9 1.1 1.0 -.1 0.7 0.5 0.4 1.2 0.8 1.0 1.1 1.0 -.1 1. 4 1.0 1.0 1.4 1.3 1. 0 1.3 1.2 -.1 1.7 1.5 1.1 1.6 1.3 1.3 1.5 1.4 -.1 1.8 1.7 1.1 1.7 1.4 1.4 1.6 1.5 -.1 1.5 0.8 1.1 1.6 1.3 1.5 1.6 1 .6 -.1 0.6 0.4 1.0 1.5 1.2 1.5 1.6 1.5 -.1 1.3 1.0 0.9 1.4 1.2 1.5 1.6 1.5 -.1 1.8 1.5 0.6 1 • 2 1.0 1.3 1.5 1.4 -. 1 1.4 0.7 0.6 1.3 1.0 1.3 1.5 1.4 -. 1 1.0 0.6 0.6 1.2 0.9 1.2 1.4 1.3 -.1 1.0 0.6 0.9 1 .6 1.2 1.2 1.4 1.3 -.1 0.3 0.2 1.4 1.6 1.5 1.4 1.6 1.5 -. 1 0.2 0.2 1.5 2.0 1.7 1.6 1.8 1.7 -.1 0.2 0.1 1.6 1.8 1.7 1.8 1.9 1.9 0.3 0.2 1.5 1.8 1.6 1.9 2.0 1.9 0.5 0.4 1.1 1.5 1.3 1,8 1.9 1.8 1.0 0.7 0.8 1.3 1.1 1.2 1.4 1.3 o.o FEBRUARY SURFACE WATER INTRAGRAVEL WATER MAX MEP.N MIN MAX MEAN 1.4 1.1 1.6 1.8 1.7 1.5 1.3 1.5 1.6 1.5 1.3 1.2 1.5 1.6 1.6 1.4 1.0 1.3 1.6 1.4 1.4 0.7 1.2 1. 5 1.3 0.1 -.1 0.6 1.2 0.9 0.0 -.1 0.4 0.6 0.5 0.0 -.1 0.3 0.5 0.4 0.0 -.1 0.2 0.4 0.4 0.0 -.1 0.3 0.4 0.3 o.o -. 1 0.3 0.4 0.3 0.0 -.1 0.3 0.4 0.3 0.0 -.1 0.3 0.3 0.3 0.0 -.1 0.2 0.3 0.3 0.0 -.1 0.2 0.3 0.3 o.o -.1 0.2 0.4 0.3 0.0 -.1 0.2 0.4 0.3 0.0 -.0 0.2 0.4 0.3 o.o -.0 0.2 0.4 0.3 o.o -.1 0.2 0.3 0.3 0.0 0.0 0.2 0.4 0.3 o.o -.1 0.2 0.4 0.3 o.o -.1 0.2 0.3 0.3 0.0 -.0 0.2 0.3 0.3 o.o -.0 0.2 0.3 0.3 o.o -.1 0.2 0.3 0.3 0.0 0.0 0.3 0.4 0.3 0.0 -.0 0.3 0.4 0.3 0.3 0.1 0.5 0.6 0.~ TABLE B-1 DATE MARCH APRIL MAY SURFACE WATER INTRAGRAVEL WATER SURFJ.CE WATER INTRAGRAVEL WATER SURFACE WATER INTRAGRAVEL WATER MIN MAX MEAN MIN MAX MEAN MIN MAX MEAN MIN MAX MEAN MIN MAX MEAN MIN MAX MEAN 1 -. 1 0.1 o.o 0.3 0.4 0.3 -.1 0.3 0.1 0.3 0.4 0.3 0.5 2.0 1.2 0.8 1.9 1.4 2 0.0 0.1 0.0 0.3 0.4 0.3 -.1 0.2 0.0 0.3 0.4 0.3 0.5 1.3 0.8 1.0 1.6 1.3 3 0.0 0.1 0.0 0.3 0.4 0.4 -.1 0.5 0.1 0.3 0.5 0.4 4 0.0 0.2 0.1 0.3 0.4 0.4 0.0 0.6 0.2 0.3 0.5 0.4 5 -.1 0.6 0.2 0.3 0.5 0.4 6 0.0 0.6 0.3 0.3 0.7 0.5 7 0.2 0.9 0.4 0.5 0.8 0.6 8 0.1 0.7 0.3 0.5 0.7 0.6 9 0.0 1 .0 0.3 0.3 0.7 0.5 10 0.0 1 .0 0.2 0.3 0.7 0.5 11 -.1 0.8 0.2 0.3 0.6 0.4 12 -. 1 0.6 0.2 0.3 0.5 0.4 13 0.0 0.9 0.2 0.3 0.6 0.4 14 -.1 1.0 0.3 0.3 0.8 0.5 15 0.2 1. 7 0.7 0.4 1. 2 0.7 16 0.2 1.2 0.4 0.5 1.0 0.6 17 0.2 1.4 0.6 0.5 1.1 0.8 18 0.2 1 .4 0.6 0.5 1.1 0.7 19 -.1 1. 3 0.5 0.3 1 .0 0.6 20 0.2 1.0 0.6 0.5 1 .0 0.8 21 0.3 1. 4 0.7 0.6 1. 3 0.9 22 0.3 1. 5 0.7 0.6 1.3 0.9 23 0.3 1. 5 0.7 0.6 1.3 0.9 24 0.1 0.5 0.3 0.5 0.6 0.6 0.4 1. 4 0.7 0.7 1.3 1.0 25 0.1 0.7 0.3 0.4 0.7 0.6 0.3 1 .5 0.7 0.6 1.3 0.9 26 0.1 0.7 0.3 0.5 0.7 0.5 0.3 1.1 0.5 0.6 1.1 0.9 27 -. 1 0.6 0.2 0.3 0.6 0.5 0.2 1.5 0.7 0.5 1.3 0.9 28 -. 1 0.6 0.2 0.3 0.6 0.4 0.3 1.7 0.8 0.6 1 .5 1.0 29 0.1 0.9 0.4 0.5 0.8 0.6 0.3 1.3 0.7 0.7 1.2 0.9 30 -.1 0.8 0.2 0.3 0.6 0.5 0.2 1.6 1.0 0.6 1 .5 1.1 31 -.1 0.4 0.1 0.3 0.4 0.3 AVERAGE -.0 0.5 0.2 0.4 0.6 0.4 0.1 1.1 0.4 0.4 0.9 0.6 0.5 1.7 1 .0 0.9 1.8 1.3 CONTINUED TABLE B-1 i I DATE MARCH SURFACE WATER I MIN MAX MEAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 0.2 0.5 0.3 25 o. 1 0.6 0.3 26 0.1 0.6 0.3 27 ' 0.0 0.5 0.2 28 0.0 0.5 0.2 29 0.1 0.7 0.4 30 0.0 0.5 0.2 31 0.0 o. 1 0.1 \ I -AVERAGE 0.1 0.5 0.2 I J J J J SURFACE AND INTRA GRAVEL WATER TEMPERATURES IN RIFFLE REACH APRIL INTRAGRAVEL WATER SURFACE WATER INTRAGRAVEL WATER MIN MAX MEAN MIN MAX MEAN MIN MAX MEAN MIN 0.0 0.2 0.1 0.3 0.4 0.4 0.5 0.0 o. 1 0.1 0.3 0.4 0.3 0.6 0.0 0.2 0.1 0.2 0.4 0.3 0.0 0.2 0.1 0.2 0.4 0.3 o.o 0.2 0.1 0.2 0.4 0.3 -.1 0.2 0.1 0.2 0.3 0.3 -.3 0.3 0.1 0.2 0.3 0.3 -.2 0.5 0.2 0.3 0.4 0.3 0.0 0.4 0.2 0.3 0.4 0.4 0.0 0.5 0.2 0.3 0.5 0.4 0.0 0.3 0.1 0.3 0.4 0.4 o.o 0.2 0.1 0.3 0.4 0.4 0.0 0.3 0.1 0.2 0.4 0.3 0.0 0.5 0.2 0.2 0.4 0.3 0.1 1 • 1 0.5 0.3 0.5 0.4 0.2 0.6 0.3 0.4 o.s 0.5 0.2 0.9 0.5 0.4 0.6 0.5 0.2 1.1 0.5 0.5 0.6 0.5 0.0 1.2 0.4 0.4 0.6 0.5 0.2 1.0 0.5 0.5 0.6 0.5 0.2 1.5 0.7 0.5 0.8 0.6 0.2 1.7 0.8 0.5 0.9 0.7 0.3 1.7 0.8 0.5 0.9 0.7 0.4 0.5 0.5 0.4 1 .4 0.8 0.6 0.9 0.8 0.3 0.5 0.5 0.2 1.6 o. i 8 0.6 1.0 0.8 0.4 0.5 0.5 0.3 1.2 0.7 0.6 0.9 0.8 0.3 0.5 0.4 0.1 1.8 0.9 0.5 1.0 0.7 0.3 0.5 0.4 0.3 2.1 1.0 0.6 1.1 0.9 0.3 0.5 0.4 0.4 1.3 0.8 0.7 1.0 0.9 0.3 0.5 0.5 0.3 2.0 1.1 0.6 1.1 0.9 0.3 0.5 0.4 0.3 0.5 0.4 0.1 0.9 0.4 0.4 0.6 0.5 0.6 MAY SURFACE WATER INTRAGRAVEL WATER MAX MEI1N MIN MAX MEAN 2.6 1.4 0.8 1.4 1.1 1.6 1.0 1.2 1.4 1.3 2.1 1.2 1.0 1.4 1.2 TABLE 8-2 APPENDIX C APPENDIX C SEDIMENT GRAIN SIZE CURVES Figure No. Title Figure C-1 Sediment Grain Size Curves for Sample 1 at Station 1 in Tree Bar Reach Collected in March 1985 Figure C-2 Sediment Grain Size Curves for Sample 2 at Station 1 in Tree Bar Reach Collected in March 1985 Figure C-3 Sediment Grain Size Curves for Sample 1 at Station 2 in Tree Bar Reach Collected in December 1984 Figure C-4 Sediment Grain Size Curves for Sample 2 at Station 2 in Tree Bar Reach Collected in December 1984 Figure C-5 Sediment Grain Size Curves for Sample 1 at Station 2 in Tree Bar Re{lch Collected in March 1985 Figure C-6 Sediment Grain Size Curves for Sample 1 at Station 3 in Tree Bar Reach Collected in March 1985 Figure C-7 Sediment Grain Size Curves for Sample 2 at Station 3 in Tree Bar Reach Collected in March 1985 Figure C-8 Sediment Grain Size Curves for Sample 1 at Station 4 in Tree Bar Reach Collected in December 1984 Figure C-9 Sediment Grain Size Curves for Sample 1 at Station 4 in Tree Bar Reach Collected in March 1985 Figure C-10 Sediment Grain Size Curves for Sample 2 at Station 4 in Tree Bar Reach Collected in March 1985 Figure C-11 Sediment Grain Size Curves for Sample 1 at Station 5 in Tree Bar Reach Collected in December 1984 Figure C-12 Sediment Grain Size Curves for Sample 2 at Station 5 in Tree Bar Reach Collected in December 1984 Figure C-13 Sediment Grain Size Curves for Sample 1 at Station 5 in Tree Bar Reach Collected in March 1985 Figure C-14 Sediment Grain Size Curves for Sample 1 at Station 1 in Riffle Reach Collected in December 1984 Figure C-15 Sediment Grain Size Curves for Sample 2 at Station 1 in Riffle Reach Collected in December 1984 D-BL-108 100 • ZONE A a ZONE B 90 0 ZONE C 80 1- J: C) 70 w ~ >-60 Ill 0: w 50 z u.. 1-40 z w (.) 0: w 30 a. 20 10 0~--~~--~--~~--~--~--~~~~~~~ 400 200 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 1 IN TREE BAR REACH COLLECTED IN MARCH 1985 r......--------FIGURE C-1 100 • ZONE A oZONE 8 90 oZONE C 80 1- J: (.!) 70 w ~ >-60 ca cr: w 50 z u. 1-40 z w (.) cr: w 30 c.. 20 10 0~--r--.,--.----.--~~----r-~~~~~~~~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 1 IN TREE BAR REACH COLLECTED IN MARCH 1985 ~------FIGURE C-2 1-:r: (!:) w ~ >-en a: w z u.. 1-z w (.) a: w a.. 100~--~~~----------------------------------~ 70 60 50 40 30 20 10 400 200 100 50 20 10 5 2 • ZONE A oZONE 8 0 ZONE C 0.5 GRAIN SIZE (mm) 0.2 0.1 0.05 SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 2 IN TREE BAR REACH COLLECTED IN DECEMBER 1984 ...._____ ______ FIGURE C-3 100 • ZONE A o ZONE 8 90 0 ZONE C 80 1- J: (!) 70 w ~ >-60 m a: w 50 z IJ.. 1-40 z w () a: w 30 a. 20 10 o4---~~--~--~~--~---r--~~~~~=F~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 2 IN TREE BAR REACH COLLECTED IN DECEMBER 1984 .____ ______ FIGURE C-4 1-:r: CD w ~ >-Ill 0: w z u. 1-z w (.') 0: w a. 100~--~~----------------------------------~ 60 50 40 30 20 10 • ZONE A o ZONE 8 oZONE C 0~~~~~~--~~--~--~~--~~~~~ 400 200 100 50 20 10 5 2 1 0..5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 2 IN TREE BAR REACH COLLECTED IN MARCH 1985 ~---------FIGURE C-5 100 • ZONE A oZONE 8 90 0 ZONE C 80 1-:z:: (!) 70 w ~ >-60 CD ex: w 50 z u. 1-40 z w () ex: w 30 c.. 20 10 o;---~~--~--~--~~----~~--~--~--~~ 400 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 3 IN TREE BAR REACH COLLECfED IN MARCH 1985 ....___ ______ FIGURE C-6 100 • ZONE A oZONE B 90 0 ZONE C 80 1-::c (!J 70 w ~ >-60 CD 0: w 50 z LL.. 1-z 40 w (.) 0: w 30 a.. 20 10 04---~~,--~--~--~~----~~--~--~--~~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 3 IN TREE BAR REACH COLLECTED IN MARCH 1985 ~------FIGURE C-7 100 • ZONE A oZONE 8 0 ZONE C 80 1-:r: ~ 70 w ;:: >-60 Cll a: w 50 ~ 1.1.. 1-40 z w (.) a: w 30 a. 20 10 0 ' 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 4 IN TREE BAR REACH COLLECTED IN DECEMBER 1984 ..___ ______ FIGURE C-8 100 • ZONE A oZONE B 90 oZONE C 80 1- J: (!:} 70 w ~ >-60 co cr: w 50 z u. 1-z 40 w () cr: w 30 a.. 20 10 oj_--~~,--~--~--~~--~=:~~~~~~~J 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 4 IN TREE BAR REACH COLLECTED IN MARCH 1985 L..o.--------FIGURE C-9 100 • ZONE A oZONE 8 90 oZONE C 80 1-:r: ~ 70 w ~ >-60 Cil 0: w 50 z u. 1-z 40 w u 0: w 30 0... 20 10 oJ-~--~~--~~~--~--~::~~~~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 4 IN TREE BAR REACH COLLECTED IN MARCH 1985 ---------FIGURE C-10 100 • ZONE A o ZONE 8 90 oZONE C 80 1- \ ::c <!) 70 w 3: >-60 '\, IIl 0: '\ w 50 z u. 1-z 40 w 0 0: w 30 0.. 20 10 ol-~--~~--~~~--~--~~~~~~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 5 IN TREE BAR REACH COLLECTED IN DECEMBER 1984 ...___------FIGURE C-11 100 • ZONE A oZONE B 90 0 ZONE C 80 1-:r: (!) 70 w ~ >-60 Q) a: w 50 z u.. 1-40 z LU u a: w 30 a. 20 10 o~~~--~~~--~~--~~~~~~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 5 IN TREE BAR REACH COLLECTED IN DECEMBER 1984 '---------FIGURE C-12 1- :X: (.!) w ~ >-co a: w z u. 1-z w () a: w a.. 100~----~._--------------------------------~ 70 60 50 40 30 20 10 A ZONE A oZONE B 0 ZONE C ol-~~~--~~~--~~~~~~j 400 200 100 50 20 10 5 2 1 0.5 0.2 o. 1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 5 IN TREE BAR REACH COLLECTED IN MARCH 1985 ..____------FIGURE C-13 100 • ZONE A oZONE B 90 0 ZONE C 80 1-:r: (!) 70 w ~ >-60 CD 0:: w 50 z -u.. 1-40 z w u 0:: 30 w a. 20 0~~--~~--~--~~--~--~~~~~~~ 400 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 1 IN RIFFLE REACH COLLECTED IN DECEMBER 1984 ..___------FIGURE C-14 1- :I: (!) w 3: >-m 0: w z u.. 1-z w (..) 0: w a.. 100~------~--------------------------------~ 60 50 40 30 20 10 • ZONE A oZONE B 0 ZONE C 0~~--~~--~--~~--~~--~~~~~ 400 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 1 IN RIFFLE REACH COLLECTED IN DECEMBER 1984 '----------FIGURE C-15 100 • ZONE A oZONE B 90 <>ZONE C 80 1- J: CD 70 w ;: > 60 fil 0: w 50 z LL. 1-40 z w (.) 0: w 30 a. 20 10 04---~~--~--~--~--~--~--~~--~~~--~ 400 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 1 IN RIFFLE REACH COLLECTED IN MARCH 1985 '---------FIGURE C-16 100 • ZONE A 90 oZONE B <> ZONE C 80 1- I (..? 70 w 3: >-60 c::o a: w 50 z u. 1-40 z w () a: w 30 a.. 20 10 o4---~~--~--~~~~--~--~~~~~~~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 2 IN RIFFLE REACH COLLECTED IN DECEMBER 1984 ----------FIGURE C-17 100 • ZONE A 90 oZONE B 0 ZONE C 80 1- I (!:I 70 w $: >-60 m 0: w 50 z u.. 1-40 z w (.) 0: w 30 a.. 20 10 0~--~~,--~--~--~--r---~--r--.----.--.--~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 2 IN RIFFLE REACH COLLECTED IN DECEMBER 1984 '----------FIGURE C-18 1- J: (!) w ~ >-Ill a: w z u.. 1-z w (.) a: w c.. 100~----~~--------------------------------~ 60 50 40 30 20 10 • ZONE A oZONE B oZONE C 04---~~.--~--~--~--~--~~--~--~--~~ 400 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 2 IN RIFFLE REACH COLLECTED IN MARCH 1985 ...___ ______ FIGURE C-19 100 • ZONE A oZONE 8 90 0 ZONE C 80 1- J: (!) 70 w 3: >-. 60 co a: w 50 z -u. 1-40 z w (.) a: w 30 a.. 20 10 04---~~--~--~--~~----~~--~--~--~--4 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 3 IN RIFFLE REACH COLLECTED IN DECEMBER 1984 .____------FIGURE C-20 100 • ZONE A o ZONE 8 90 0 ZONE C 80 1-:c (!) 70 w ~ >-60 co a: w 50 z LL. 1-z 40 w (..) a: w 30 a.. 20 10 04---~~--~--~--~--~--~--~~--~--~--~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 3 IN RIFFLE REACH COLLECTED IN DECEMBER 1984 .....___ ______ FIGURE C-21 100 • ZONE A oZONE 8 oZONE C 80 1-:c 0 w !l: >-60 Ill a: w 50 z u. 1-z 40 w (.) a: w 30 c.. 04---~~--~--~--~--~--~--.--.----.--.--~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 3 IN RIFFLE REACH COLLECTED IN MARCH 1985 L....-.--------FIGURE C-22 100 • ZONE A oZONE B 90 0 ZONE C 80 1- I C) 70 w !: >-60 co a: w 50 z u. 1-z 40 w (.) a: w 30 a. 20 10 0~--------~--~--~--.---.---r--.----r-~--~ 400 200 100 50 20 10 5 2 1 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 3 IN RIFFLE REACH COLLECTED IN MARCH 1985 ..._____ ______ FIGURE C-23 100 A ZONE A oZONE 8 90 oZONE C 80 1- J: CD 70 w ~ >-60 Ill a: w 50 z -Ll.. 1-z 40 w 0 a: w 30 a.. 20 10 o,_--~~--~--~--~--~--~~~~--~--~--1 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm} SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 4 IN RIFFLE REACH COLLECTED IN MARCH 1985 ..___ ______ FIGURE C-24 1-:r: CJ w ~ >-co 0: w z IJ... 1-z w (.) 0: w a.. 100~----~r-----------------------------------, 70 60 50 40 30 20 10 .to ZONE A oZONE 8 0 ZONE C 04---~~~--~--~--~--~--~--~~----~-.--~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 4 IN RIFFLE REACH COLLECTED IN MARCH 1985 "---------FIGURE C-25 100 .t. ZONE A o ZONE B 90 oZONE C 80 .__ J: <!:) 70 w 3; >-60 m a: w 50 z u. .__ z 40 w () a: w 30 a.. 20 10 04---~~,---r--~---r--.---.---.-~----.-~--~ 400 200 100 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 1 AT STATION 5 IN RIFFLE REACH COLLECTED IN MARCH 1985 '---------FIGURE C-26 100 • ZONE A o ZONE B 90 0 ZONE C 80 1- J: C) 70 w ~ >-60 co 0: w 50 z -u... 1-40 z w 0 0: w 30 a. 20 10 0~--~~--~--~~~~--~--~~~~~~~ 400 200 50 20 10 5 2 0.5 0.2 0.1 0.05 GRAIN SIZE (mm) SEDIMENT GRAIN SIZE CURVES FOR SAMPLE 2 AT STATION 5 IN RIFFLE REACH COLLECTED IN MARCH 1985 .____------FIGURE C-27 APPENDIX D APPENDIX D WATER TEMPERATURE DATA, MAY 2 -DECEMBER 28, 1985 Report No. Period 1 May 3 to August 3, 1985 2 August 1 to August 31, 1985 3 August 31 to December 28, 1985 D-BL-108 ... .. - - • • D-BL/107 Bradley Lake Hydroelectric Project Environmental Monitoring Program Water Quality Data Report Submitted to Stone and Webster Engineering Corporation 510 L Street, Suite 310 Anchorage, Alaska Attention: Mr. T. Critikos by NORTHERN TECHNICAL SERVICES, INC • The Bradley River is currently being monitored at three locations for water temperature. As part of the 1985 environmental monitoring program instruments maintained at these locations are serviced; data storage chips retrieved; data recovered form chips (by Dryden and Larue); and the summarized data is transmitted in report from to Stone and Webster Engineering Corporation. This is the first in a series of reports covering the water quality task and includes the data obtained from the initial servicing of water quality instruments. The temperature sensors were serviced August 1 and 3, 1985. It was necessary to use a helicopter to reach the North Fork site. A summary of the servicing follows: 1. Tree Bar Reach, serviced August 1, 1985/1700 hrs. Unit appeared to be functioning properly; "short dump" performed. Data storage module (DSM) was replaced and initialized for August 1/1800 hrs, in agreement with the previous DSM. Some of the new dry cell batteries yielded the "Lo Bat" indicator, so these were replaced with a second set. The "ammo box" shelter was painted bright orange for easy location on the next field service visit. The unit appeared to be functioning properly after servicing. 2. Riffle Reach, serviced August 1, 1985/1800 hrs. Unit yielded no display; batteries were apparently expired. DSM and batteries were replaced and initialized for 2400 hrs/August 1, Channel 1 read 11 -05.0C" during short dump at startup; replacement of the Datapod and/or a probe may be required. The "ammo box" shelter was painted bright orange. This unit should be re-serviced as soon as possible. D-BL/107 D-BL/107 ATTACHMENT I Riffle Reach Water Quality Data May 2, 1985 through August 25, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 05/02/85 24:00 1.0 0.7 1.4 1.1 1.0 1.1 05/03/85 06:00 2.1 1.5 2.4 1.1 1.0 1.2 05/03/85 12:00 1.8 1.7 1.9 1.4 1.2 1.4 05/03/85 18:00 1.5 0.9 1.9 1.4 1.3 1.4 05/03/85 24:00 1.0 0.8 1.4 1.2 1.2 1.4 05/04/85 06:00 1.7 1.3 2.0 1.2 1.2 1.3 05/04/85 12:00 1.8 1.5 2.0 1.4 1.3 1.4 05/04/85 18:00 2.2 0.9 4.4 1.4 1.4 1.5 05/04/85 24:00 1.0 0.7 1.7 1.4 1.2 1.5 05/05/85 06:00 2.8 1.7 3.9 1.4 1.3 1.6 05/05/85 12:00 2.2 1.9 2.4 1.6 1.6 1.7 05/05/85 18:00 3.0 1.0 5.4 1.7 1.6 1.8 05/05/85 24:00 1.0 0.8 1.3 1.7 1.5 1.9 05/06/85 06:00 2.0 1.2 2.9 1.5 1.4 1.3 05/06/85 12:00 2.0 1.7 2.3 1.6 1.5 1.7 05/06/85 18:00 2.7 1.4 4.9 1.6 1.5 1.7 05/06/85 24:00 1.2 1.0 2.5 1.6 1.5 1.7 05/07/85 06:00 2.8 1.8 3.9 1.6 1.5 1.8 05/07/85 12:00 -0.9 -5.0 3.3 1.8 1.7 1.9 05/07/85 18:00 -3.8 -4.8 2.5 1.6 1.5 1.8 05/07/85 24:00 -4.6 -4.8 2.5 1.5 1.4 1.6 05/08/85 06:00 -4.8 -4.8 -4.8 1.4 1.4 1.3 05/08/85 12:00 -4.0 -4.8 1.7 1.5 1.5 1.6 05/08/85 18:00 -4.0 -4.8 1.7 1.5 1.5 1.6 05/08/85 24:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/09/85 06:00 -4.8 -4.8 -4.8 1.3 1.2 1.4 05/09/85 12:00 -4.8 -4.8 -4.8 1.5 1.3 1.5 05/09/85 18:00 -4.8 -4.8 -4.8 1.5 1.4 1.5 05/09/85 24:00 -4.8 -4.8 -4.8 1.3 1.2 1.4 05/10/85 06:00 -4.8 -4.8 -4.8 1.3 1.2 1.4 05/10/85 12:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/10/85 18:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/10/85 24:00 -4.8 -4.8 -4.8 1.2 1.1 1.4 05/11/85 06:00 -4.8 -4.8 -4.8 1.2 1.1 1.3 05/11/85 12:00 -3.0 -4.8 2.2 1.4 1.3 1.5 05/11/85 18:00 -4.8 -4.8 -4.8 1.5 1.4 1.5 05/11/85 24:00 -4.8 -4.8 -4.8 1.3 1.2 1.5 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 05/12/85 06:00 -4.6 -4.8 2.0 1.3 1.2 1.5 05/12/85 12:00 -4.8 -4.8 -4.8 1.6 1.4 1.7 05/12/85 18:00 -4.8 -5.0 -4.8 1.7 1.5 1.7 05/12/85 24:00 -4.8 -4.8 -4.8 1.5 1.4 1.6 05/13/85 06:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/13/85 12:00 -4.8 -4.8 -4.8 1.6 1.5 1.6 05/13/85 18:00 -4.8 -5.0 -4.8 1.6 1.5 1.6 05/13/85 24:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/14/85 06:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/14/85 12:00 -4.8 -4.8 -4.8 1.5 1.5 1.6 05/14/85 18:00 -4.8 -4.8 -4.8 1.6 1.5 1.7 05/14/85 24:00 -4.8 -4.8 -4.8 1.4 1.4 1.5 05/15/85 06:00 -4.8 -4.8 -4.8 1.4 1.3 1.5 05/15/85 12:00 -4.8 -4.8 -4.8 1.5 1.5 1.6 05/15/85 18:00 -4.8 -4.8 -4.8 1.6 1.5 1.7 05/15/85 24:00 -4.8 -4.8 -4.8 1.5 1.4 1.6 05/16/85 06:00 -4.8 -4.8 -4.8 1.5 1.4 1.6 05/16/85 12:00 -4.9 -5.0 -4.8 1.8 1.6 2.0 05/16/85 18:00 -5.0 -5.0 -5.0 1.8 1.7 2.0 05/16/85 24:00 -5.0 -5.0 -5.0 1.6 1.5 1.7 05/17/85 06:00 -4.7 -5.0 2.2 1.7 1.5 1.9 05/17/85 12:00 -4.8 -4.8 -4.8 2.0 1.9 2. 1 05/17/85 18:00 -4.8 -4.8 -4.8 1.9 1.7 2.1 05/17/85 24:00 -4.8 -4.8 -4.8 1.6 1.6 1.8 05/18/85 06:00 -4.8 -5.0 -4.8 1.6 1.6 1.7 05/18/85 12:00 -4.6 -5.0 1.4 1.6 1.6 1.7 05/18/85 18:00 -4.8 -5.0 1.0 1.6 1.5 1.6 05/18/85 24:00 -5.0 -5.0 -4.8 1.5 1.4 1.5 05/19/85 06:00 -4.8 -5.0 -4.8 1.5 1.4 1.7 05/19/85 12:00 -3.1 -4.8 1.8 1.7 1.6 1.8 05/19/85 18:00 -3.1 -5.0 1.0 1.7 1.6 1.7 05/19/85 24:00 -1.5 -5.0 1.2 1.5 1.5 1.6 05/20/85 06:00 -3.9 -5.0 0.2 1.5 1.4 1.5 05/20/85 12:00 2.1 1.7 2.3 1.6 1.5 1.7 05/20/85 18:00 1.1 0.6 1.7 1.6 1.5 1.7 05/20/85 24:00 -2.7 -4.8 0.6 1.4 1.3 1.5 05/21/85 06:00 -4.5 -5.0 2.3 1.4 1.3 1.6 05/21/85 12:00 -4.7 -4.9 -0.3 1.9 1.6 2.0 05/21/85 18:00 -3.4 -5.0 0.9 1.9 1.7 2.1 05/21/85 24:00 -3.4 -4.8 0.7 1.5 1.4 1.7 D-BL/107 NORTEC FOR AI.ASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX -- 05/22/85 06:00 -4.8 -4.8 -4.8 1.5 1.4 1.6 05/22/85 12:00 -4.5 -4.8 1.8 2.0 1.7 2.1 05/22/85 18:00 -1.4 -4.8 1.3 1.8 1.6 2.1 05/22/85 24:00 -4.8 -4.8 -4.8 1.5 1.4 1.7 05/23/85 06:00 -1.1 -4.8 3.3 1.5 1.4 1.7 05/23/85 12:00 -2.0 -5.0 3.4 1.9 1.8 2.0 05/23/85 18:00 -3.2 -4.8 0.8 1.8 1.6 2.0 05/23/85 24:00 -2.6 -5.0 1.7 1.5 1.4 1.6 05/24/85 06:00 -1.7 -5.0 3.0 1.5 1.4 1.7 05/24/85 12:00 -2.3 -5.0 2.9 1.8 1.7 1.9 05/24/85 18:00 -2.9 -5.0 1.0 1.7 1.6 1.8 05/24/85 24:00 -3.8 -5.0 0.4 1.5 1.5 1.6 05/25/85 06:00 -2.9 -5.0 2.0 1.5 1.5 1.6 05/25/85 12:00 -2.2 -5.0 2.0 1.7 1.6 1.7 05/25/85 18:00 -2.8 -5.0 1.4 1.6 1.5 1.6 05/25/85 24:00 -2.6 -5.0 1.3 1.5 1.4 1.5 05/26/85 06:00 -3.7 -5.0 1.9 1.5 1.5 1.5 05/26/85 12:00 -2.3 -5.0 1.7 1.5 1.5 1.6 05/26/85 18:00 -3.1 -5.0 0.7 1.5 1.4 1.5 05/26/85 24:00 -3.9 -5.0 1.2 1.4 1.3 1.4 05/27/85 06:00 -4.2 -5.0 1.9 1.4 1.3 1.5 05/27/85 12:00 -1.9 -5.0 1.8 1.5 1.5 1.6 05/27/85 18:00 -3.4 -5.0 0.7 1.5 1.4 1.6 05/27/85 24:00 -4.1 -5.0 0.9 1.4 1.3 1.5 05/28/85 06:00 -3.4 -5.0 2.3 1.5 1.3 1.6 05/28/85 12:00 -4.5 -5.0 1.8 1.6 1.6 1.6 05/28/85 18:00 -4.8 -5.0 0.9 1.6 1.5 1.6 05/28/85 24:00 -4.5 -5.0 0.9 1.5 1.5 1.5 05/29/85 06:00 -4.0 -5.0 1.5 1.5 1.5 1.6 05/29/85 12:00 -4.3 -5.0 1.5 1.6 1.5 1.6 05/29/85 18:00 -4.6 -5.0 0.0 1.5 1.4 1.6 05/29/85 24:00 -2.9 -5.0 1.3 1.5 1.4 1.5 05/30/85 06:00 -4.0 -5.0 1.3 1.4 1.4 1.5 05/30/85 12:00 -3.9 -5.0 1.6 1.5 1.5 1.6 05/30/85 18:00 -2.9 -5.0 1.2 1.5 1.4 1.5 05/30/85 24:00 -4.5 -5.0 1.1 1.5 1.4 1.5 05/31/85 06:00 -4.7 -5.0 -0.7 1.5 1.4 1.5 05/31/85 12:00 -4.6 -5.0 -0.6 1..5 1.5 1.5 05/31/85 18:00 -4.4 -5.0 0.6 1.5 1.5 1.5 05/31/85 24:00 -4.2 -5.0 1.1 1.5 1.4 1.5 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 06/01/85 06:00 -4.6 -5.0 1.5 1.5 1.4 1.5 06/01/85 12:00 -2.9 -5.0 1.3 1.5 1.5 1.5 06/01/85 18:00 -3.5 -5.0 1.2 1.4 1.4 1.5 06/01/85 24:00 -2.8 -5.0 1.2 1.4 1.4 1.5 06/02/85 06:00 -5.0 -5.0 -5.0 1.5 1.4 1.6 06/02/85 12:00 -3.3 -5.0 -0.2 1.6 1.5 1.7 06/02/85 18:00 -1.4 -3.7 0.0 1.5 1.5 1.6 06/02/85 24:00 -4.7 -5.0 -3.1 1.5 1.5 1.5 06/03/85 06:00 -4.4 -5.0 2.0 1.5 1.5 1.6 06/03/85 12:00 -4.4 -5.0 1.6 1.6 1.5 1.7 06/03/85 18:00 -4.6 -5.0 -1.5 1.6 1.5 1.6 06/03/85 24:00 -1.9 -5.0 0.8 1. 6 1.6 1.6 06/04/85 06:00 -1.9 -5.0 1.8 1.7 1.6 1.7 06/04/85 12:00 -3.0 -5.0 -0.6 1.7 1.7 1.8 06/04/85 18:00 -2.6 -5.0 1.4 1.7 1.6 1.7 06/04/85 24:00 -2.9 -5.0 0.5 1.6 1.5 1.7 06/05/85 06:00 -2.9 -5.0 1.1 1.6 1.5 1.7 06/05/85 12:00 -3.6 -5.0 1.6 1.7 1.6 1.7 06/05/85 18:00 -5 .o -5.0 -5.0 1.6 1.6 1.7 06/05/85 24:00 -4.8 -5.0 -2.6 1.6 1.5 1.6 06/06/85 06:00 -5.0 -5.0 -5.0 1.6 1.5 1.7 06/06/85 12:00 -5.0 -5.0 -5.0 1.8 1.7 1.8 06/06/85 18:00 -5.0 -5.0 -5.0 1.7 1.6 1.8 06/06/85 24:00 -5.0 -5.0 -5.0 1.6 1.5 1.7 06/07/85 06:00 -5.0 -5.0 -4.5 1.7 1.5 1.8 06/07/85 12:00 -2.9 -5.0 2.3 1.9 1.8 1.9 06/07/85 18:00 -4.1 -5.0 0.3 1.8 1.8 1.9 06/07/85 24:00 -3.6 -5.0 2.0 1.7 1.7 1.8 06/08/85 06:00 -1.6 -5.0 2.4 1.8 1.7 1.8 06/08/85 12:00 -3.8 -5.0 2.3 1.9 1.8 2.0 06/08/85 18:00 -4.1 -5.0 1.6 1.9 1.8 1.9 06/08/85 24:00 -3.3 -5.0 1.9 1.8 1.7 1.8 06/09/85 06:00 -3.5 -5.0 2.2 1.8 1.7 1.9 06/09/85 12:00 -3.8 -5.0 1.9 2.0 1.9 2.1 06/09/85 18:00 -2.6 -5.0 1.3 2.0 1.9 2.0 06/09/85 24:00 -3.7 -5.0 1.4 1.9 1.8 1.9 06/10/85 06:00 -2.3 -5.0 1.5 1.9 1.8 2. 1 06/10/85 12:00 -3.6 -5.0 -0.4 2.1 2.0 2.2 06/10/85 18:00 -4.6 -5.0 -0.3 2.1 2.0 2.2 06/10/85 24:00 -4.6 -5.0 1.2 1.9 1.8 2.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 06/11/85 06:00 -3.4 -5.0 1.9 2.0 1.8 2. 1 06/11/85 12:00 -3.8 -5.0 0.1 2. 1 2.1 2.2 06/11/85 18:00 -4.0 -5.0 -0.5 2.1 2.1 2.2 06/11/85 24:00 -4.5 -5.0 0.9 2.0 1.9 2.1 06/12/85 06:00 -1.7 -5.0 3.4 2.1 2.0 2.3 06/12/85 12:00 -2.5 -5.0 3.0 2.4 2.3 2.5 06/12/85 18:00 -3.5 -5.0 2.0 2.4 2.3 2.5 06/12/85 24:00 -4.1 -5.0 2.7 2.3 2.2 2.3 06/13/85 06:00 -1.2 -5.0 3.4 2.3 2.2 2.4 06/13/85 12:00 -3.2 -5.0 3.1 2.5 2.4 2.5 06/13/85 18:00 -3.6 ·-5.0 2.4 2.5 2.3 2.5 06/13/85 24:00 -4.3 -5.0 2.1 2.3 2.2 2.4 06/14/85 06:00 -3.0 -5.0 3.8 2.4 2.2 2.5 06/14/85 12:00 -3.9 -5.0 3.2 2.6 2.5 2.7 06/14/85 18:00 -3.0 -5.0 2.5 2.6 2.5 2.6 06/14/85 24:00 -3.3 -5.0 2.3 2.4 2.3 2.5 06/15/85 06:00 -2.3 -5.0 4.2 2.4 2.3 2.6 06/15/85 12:00 -2.7 -5.0 3.8 2.7 2.6 2.8 06/15/85 18:00 -4.7 -5.0 2.1 2.6 2.5 2.8 06/15/85 24:00 -3.9 -5.0 2.0 2.4 2.3 2.6 06/16/85 06:00 -4.4 -5.0 3.3 2.5 2.4 2.7 06/16/85 12:00 -4.4 -5.0 2.9 2.8 2.7 2.9 06/16/85 18:00 -3.4 -5.0 1.8 2.8 2.7 2.9 06/16/85 24:00 -3.9 -5.0 2.2 2.6 2.5 2.7 06/17/85 06:00 -4.8 -5.0 2.6 2.7 2.5 2.9 06/17/85 12:00 -3.4 -5.0 3.6 2.8 2.8 2.9 06/17/85 18:00 -4.2 -5.0 1.9 2.7 2.5 2.9 06/17/85 24:00 -3.7 -5.0 2.0 2.5 2.5 2.6 06/18/85 06:00 -4.7 -5.0 2.8 2.5 2.5 2.6 06/18/85 12:00 -4.9 -5.0 -4.8 2.6 2.5 2.6 06/18/85 18:00 -4.9 -5.0 -2.3 2.6 2.5 2.6 06/18/85 24:00 -4.9 -5.0 -3.8 2.5 2.5 2.6 06/19/85 06:00 -5.0 -5.0 -4.8 2.7 2.5 3.0 06/19/85 12:00 -5.0 -5.0 -5.0 3.1 3.0 3. 1 06/19/85 18:00 -5.0 -5.0 -4.8 3.0 2.9 3. 1 06/19/85 24:00 -4.9 -5.0 -4.8 2.8 2.8 3.0 06/20/85 06:00 -4.8 -5.0 1.9 2.9 2.8 3.0 06/20/85 12:00 -3.5 -5.0 2.8 3.0 3.0 3.1 06/20/85 18:00 -4.6 -5.0 2.8 3.0 2.9 3.1 06/20/85 24:00 -4.8 -5.0 -2.3 2.8 2.7 2.9 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 PREPARED BY DRYDEN & LARUF. DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 06/21/85 06:00 -4.8 -5.0 1.2 2.8 2.7 2.9 06/21/85 12:00 -5.0 -5.0 -4.8 3.0 2.9 3.2 06/21/85 18:00 -4.9 -5.0 -0.3 3.0 2.9 3.1 06/21/85 24:00 -5.0 -5.0 -4.8 2.9 2.8 3.0 06/22/85 06:00 -4.9 -5.0 3.0 3.0 2.8 3.1 06/22/85 12:00 -5.0 -5.0 -5.0 3.2 3.1 3.3 06/22/85 18:00 -5.0 -5.0 -4.8 3.2 3.0 3.3 06/22/85 24:00 -5.0 -5.0 -5.0 3.0 2.9 3.1 06/23/85 06:00 -5.0 -5.0 -4.8 3.1 2.9 3.4 06/23/85 12:00 -5.0 -5.0 -4.8 3.5 3.4 3.6 06/23/85 18:00 -5.0 -5.0 -5.0 3.5 3.3 3.6 06/23/85 24:00 -5.0 -5.0 -4.8 3.3 3.2 3.4 06/24/85 06:00 -5.0 -5.0 -5.0 3.2 3.2 3.3 06/24/85 12:00 -5.0 -5.0 -5.0 3.4 3.3 3.4 06/24/85 18:00 -5.0 -5.0 -4.8 3.4 3.2 3.4 06/24/85 24:00 -5.0 -5.0 -5.0 3.2 3.1 3.3 06/25/85 06:00 -5.0 -5.0 -4.9 3.2 3.1 3.3 06/25/85 12:00 -5.0 -5.0 -5.0 3.4 3.3 3.5 06/25/85 18:00 -5.0 -5.0 -5.0 3.4 3.4 3.5 06/25/85 24:00 -4.9 -5.0 -4.8 3.3 3.3 3.4 06/26/85 06:00 -4.9 -5.0 -4.3 3.3 3.3 3.4 06/26/85 12:00 -4.8 -5.0 -1.9 3.4 3.4 3.4 06/26/85 18:00 -4.9 -5.0 -2.9 3.4 3.4 3.4 06/26/85 24:00 -4.8 -5.0 -2.5 3.4 3.3 3.4 06/27/85 06:00 -4.9 -5.0 -2.7 3.4 3.3 3.6 06/27/85 12:00 -4.9 -5.0 -2.1 3.7 3.6 3.9 06/27/85 18:00 -4.8 -5.0 3.1 3.8 3.6 3.9 06/27/85 24:00 -4.9 -5.0 -2.9 3.5 3.4 3.7 06/28/85 06:00 -4.9 -5.0 -3.5 3.6 3.4 3.9 06/28/85 12:00 -4.6 -5.0 -1.7 4.1 3.9 4.2 06/28/85 18:00 -4.8 -5.0 -1.9 4.1 3.9 4.3 06/28/85 24:00 -4.8 -5.0 -2.6 3.8 3.7 3.9 06/29/85 06:00 -4.8 -5.0 -2.2 3.9 3.7 4.1 06/29/85 12:00 -5.0 -5.0 -3.5 4.2 4.1 4.4 06/29/85 18:00 -4.9 -5.0 -4.8 4.2 4. 1 4.4 06/29/85 24:00 -4.9 -5.0 -2.5 3.9 3.8 4.1 06/30/85 06:00 -4.6 -5.0 -0.5 4.0 3.9 4.2 06/30/85 12:00 -4.7 -5.0 0.3 4.3 4.1 4.4 06/30/85 18:00 -4.7 -5.0 -2.2 4.3 4. 1 4.4 06/30/85 24:00 -4.6 -5.0 -0.6 4.1 4.0 4.2 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MA.,'{ 07/01/85 06:00 -4.9 -5.0 -3.2 4.2 4. 1 4.4 07/01/85. 12:00 -4.9 -5.0 -2.9 4.5 4.4 4.5 07/01/85 18:00 -4.9 -5.0 1.5 4.4 4.3 4.5 07/01/85 24:00 -4.7 -5.0 3.9 4.4 4.3 4.4 07/02/85 06:00 -3.9 -5.0 5.2 4.4 4.3 4.4 07/02/85 12:00 -3.9 -5.0 5.4 4.5 4.4 4.5 07/02/85 18:00 -4.5 -5.0 3.7 4.4 4.3 4.5 07/02/85 24:00 -4.5 -5.0 3.8 4.3 4.2 4.4 07/03/85 06:00 -5.0 -5.0 -4.8 4.3 4.2 4.3 07/03/85 12:00 -4.4 -5.0 1.0 4.3 4.3 4.4 07/03/85 18:00 0.5 -5.0 4.5 4.3 4.2 4.3 07/03/85 24:00 -0.4 -5.0 4.6 4.2 4.2 4.3 07/04/85 06:00 -0.8 -5.0 4.5 4.2 4.2 4.3 07/04/85 12:00 0.4 -5.0 4.6 4.2 4.2 4.3 07/04/85 18:00 -0.5 -5.0 4.2 4.2 4.2 4.3 07/04/85 24:00 -1.5 -5.0 4.5 4.2 4.1 4.2 07/05/85 06:00 -1.1 -5.0 5.5 4.3 4.1 4.4 07/05/85 12:00 -0.6 -5.0 5.5 4.5 4.4 4.5 07/05/85 18:00 -3.8 -5.0 4.1 4.4 4.3 4.5 07/05/85 24:00 -2.1 -5.0 5.0 4.3 4.2 4.3 07/06/85 06:00 -0.8 -5.0 6.3 4.4 4.2 4.6 07/06/85 12:00 -3.0 -5.0 6.0 4.6 4.5 4.7 07/06/85 18:00 -3.3 -5.0 4.5 4.6 4.5 4.7 07/06/85 24:00 -3.9 -5.0 5.0 4.4 4.3 4.5 07/07/85 06:00 -3.3 -5.0 6.4 4.5 4.3 4.7 07/07/85 12:00 -4.3 -5.0 3.3 4.8 4.6 4.9 07/07/85 18:00 -4.4 -5.0 5.3 4.9 4.8 5.0 07/07/85 24:00 -4.3 -5.0 4.9 4.8 4.7 4.9 07/08/85 06:00 -5.0 -5.0 -4.8 4.8 4.7 4.8 07/08/85 12:00 -4.7 -5.0 -2.5 4.8 4.7 4.8 07/08/85 18:00 -4.4 -5.0 4.6 4.7 4.6 4.8 07/08/85 24:00 -5.0 -5.0 -4.5 4.6 4.5 4.7 07/09/85 06:00 -5.0 -5.0 -4.2 4.6 4.5 4.8 07/09/85 12:00 -4.9 -5.0 -3.7 4.7 4.7 4.8 07/09/85 18:00 -4.1 -5.0 4.8 4.7 4.7 4.8 07/09/85 24:00 -4.7 -5.0 2.7 4.6 4.6 4.7 07/10/85 06:00 -4.4 -5.0 -1.7 4.8 4.6 4.9 07/10/85 12:00 -4.3 -5.0 -1.7 5.0 4.9 5. 1 07/10/85 18:00 -4.8 -5.0 -2.6 5.0 4.9 5.1 07/10/85 24:00 -5.0 -5.0 -5.0 4.8 4.7 5.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 8 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 07/11/85 06:00 -5.0 -5.0 -5.0 4.9 4.8 5.1 07/11/85 12:00 -3.9 -5.0 5.5 5.1 5.0 5.1 07/11/85 18:00 -4.9 -5.0 -3.6 5.0 4.9 5.1 07/11/85 24:00 -4.9 -5.0 -4.8 4.9 4.8 5.0 07/12/85 06:00 -4.8 -5.0 -3.2 4.9 4.8 5. 1 07/12/85 12:00 -4.2 -5.0 -0.7 5.1 5.0 5.2 07/12/85 18:00 -4.7 -5.0 -1.9 5.2 5. 1 5.3 07/12/85 24:00 -2.8 -5.0 0.4 5.1 5.1 5.2 07/13/85 06:00 -4.1 -5.0 0.8 5.3 5.1 5.4 07/13/85 12:00 -4.7 -5.0 -2.7 5.5 5.4 5.6 07/13/85 18:00 -3.5 -5.0 -0.1 5.5 5.5 5.6 07/13/85 24:00 -4.7 -5.0 -2.5 5.5 5.4 5.5 07/14/85 06:00 -4.8 -5.0 -2.8 5.5 5.5 5.7 07/14/85 12:00 -4.8 -5.0 -2.2 5.8 5.6 5.8 07/14/85 18:00 -4.9 -5.0 -1.7 5.7 5.7 5.9 07/14/85 24:00 -4.3 -5.0 0.7 5.6 5.5 5.7 07/15/85 06:00 -5.0 -5.0 -4.8 5.7 5.5 5.8 07/15/85 12:00 -5.0 -5.0 -4.8 5.9 5.8 6.0 07/15/85 18:00 -4.4 -5.0 -2.1 5.9 5.8 6.0 07/15/85 24:00 -4.3 -5.0 -1.4 5.7 5.6 5.8 07/16/85 06:00 -4.3 -5.0 3.0 5.8 5.6 5.9 07/16/85 12:00 -4.9 -5.0 -4.8 6.0 5.9 6.1 07/16/85 18:00 -4.8 -5.0 -4.8 6.0 5.9 6.1 07/16/85 24:00 -4.8 -5.0 -4.8 5.9 5.8 5.9 07/17/85 06:00 -4.9 -5.0 -4.8 5.8 5.7 5.9 07/17/85 12:00 -4.7 -5.0 -0.5 6.0 5.9 6.1 07/17/85 18:00 -4.8 -5.0 -1.2 6.0 5.9 6.0 07/17/85 24:00 -4.7 -5.0 -1.7 5.9 5.8 6.0 07/18/85 06:00 -4.7 -5.0 -1.9 6.0 5.9 6.2 07/18/85 12:00 -4.6 -5.0 0.4 6.3 6.2 6.4 07/18/85 18:00 -4.8 -5.0 -2.8 6.3 6.3 6.4 07/18/85 24:00 -5.0 -5.0 -5.0 6.2 6.2 6.3 07/19/85 06:00 -4.0 -5.0 -1.3 6.3 6.2 6.4 07/19/85 12:00 -2.8 .o -0.1 6.4 6.3 6.4 07/19/85 18:00 -3.7 -5.0 -0.7 6.4 6.3 6.5 07/19/85 24:00 -3.3 -5.0 0.5 6.4 6.3 6.4 07/20/85 06:00 -4.0 -5.0 -0.8 6.3 6.3 6.4 07/20/85 12:00 -2.2 -5.0 6.9 6.4 6.3 6.4 07/20/85 18:00 -4.1 -5.0 5.1 6.3 6.3 6.4 07/20/85 24:00 -2.4 -5.0 5.9 6.2 6.1 6.3 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 9 PREPARED BY DRYDEN & LARUE DATA FILE RRTTC.POD 23-AUG-85 RIFFLE REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 07/21/85 06:00 -2.4 -5.0 7.0 6.2 6.1 6.5 07/21/85 12:00 -1.8 -5.0 6.4 6.4 6.3 6.5 07/21/85 18:00 -3.4 -5.0 5.3 6.4 6.3 6.5 07/21/85 24:00 -4.6 -5.0 1.2 6.3 6.2 6.4 07/22/85 06:00 -4.9 -5.0 -3.2 6.3 6.2 6.4 07/22/85 12:00 -3.1 -5.0 -0.1 6.4 6.3 6.4 07/22/85 18:00 -4.1 -5.0 -2.3 6.4 6.3 6.4 07/22/85 24:00 -2.7 -4.2 -1.0 6.3 6.3 6.3 07/23/85 06:00 -3.0 -5.0 -0.3 6.2 6.2 6.3 07/23/85 12:00 -4.4 -5.0 -0.8 6.4 6.3 6.4 07/23/85 18:00 -1.9 -4.9 -0.5 6.4 6.3 6.4 07/23/85 24:00 -3.5 -5.0 -0.4 6.3 6.2 6.3 07/24/85 06:00 -3.3 -5.0 -0.1 6.2 6.2 6.3 07/24/85 12:00 -4.0 -5.0 -1.2 6.4 6.3 6.5 07/24/85 18:00 -4.2 -5.0 -0.6 6.4 6.3 6.5 07/24/85 24:00 -4.6 -5.0 -2.1 6.3 6.3 6.4 07/25/85 06:00 -4.7 -5.0 -0.5 6.4 6.3 6.5 07/25/85 12:00 2.7 20.5 20.5 20.5 20.5 20.5 D-BL/107 D-BL/107 Attachment II Tree Bar Reach Water Quality Data May 2, 1985 through August 26, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUC:-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 05/02/85 24:00 0.8 0.7 1.0 1.1 1.0 1.1 05/03/85 06:00 1.4 1.0 1.7 1.4 1.1 1.6 05/03/85 12:00 1.8 1.6 2.0 1.7 1. 5 1.8 05/03/85 18:00 1.1 0.7 1.6 1.7 1.5 1.8 05/03/85 24:00 0.8 0.7 1.0 1.4 1.3 1.5 05/04/85 06:00 1.3 1.0 1.7 1.5 1.4 1.6 05/04/85 12:00 1.6 1.5 1.7 1.7 1.5 1.8 05/04/85 18:00 1.1 0.8 1.5 1.7 1.5 1.7 05/04/85 24:00 0.8 0.6 1.2 1.4 1.3 1.7 05/05/85 06:00 1.6 1.2 1.9 1.5 1.4 1.6 05/05/85 12:00 2.0 1.7 2.1 1.8 1.5 2.0 05/05/85 18:00 1.1 0.7 1.8 1.8 1.5 2.0 05/05/85 24:00 0.7 0.6 0.8 1.8 1.5 1.9 05/06/85 06:00 1.3 0.8 1.8 1.6 1.5 1.7 05/06/85 12:00 1.8 1.5 2.0 1.8 1.6 1.9 05/06/85 18:00 1.1 0.8 1.5 1.7 1.5 1.9 05/06/85 24:00 0.9 0.7 1.3 1.7 1.6 1.8 05/07/85 06:00 1.8 1.3 2.2 1.7 1.6 1.9 05/07/85 12:00 1.7 1.3 2.1 2.0 1.8 2.0 05/07/85 18:00 0.9 0.7 1.3 1.9 1.4 2.0 05/07/85 24:00 o. 7 0.6 1.1 1.8 1.7 1.9 05/08/85 06:00 1.5 1.1 1.9 1.7 1.6 1.7 05/08/85 12:00 1.8 1.4 2.0 1.9 1.7 1.9 05/08/85 18:00 1.1 0.8 1.4 1.8 1.6 1.9 05/08/85 24:00 0.7 0.5 0.8 1.7 1.6 1.8 05/09/85 06:00 1.2 o. 7 1.7 1.6 1.5 1.7 05/09/85 12:00 1.8 1.5 2.1 1.7 1.5 1.8 05/09/85 18:00 0.9 0.6 1.5 1.8 1.7 1.8 05/09/85 24:00 0.6 0.5 0.9 1.6 1.5 1.7 05/10/85 06:00 1.3 0.9 1.8 1.5 1.4 1.5 05/10/85 12:00 1.7 1.5 1.8 1.6 1.5 1.7 05/10/85 18:00 1.0 0.7 1.4 1.7 1.6 1.7 05/10/85 24:00 0.6 0.5 0.7 1.5 1.4 1.6 05/11/85 06:00 1.2 0.7 1.8 1.4 1.3 1.5 05/11/85 12:00 1.9 1.7 2.0 1.6 1.4 1.7 05/11/85 18:00 1.1 0.7 1.7 1.7 1.7 1.8 05/11/85 24:00 0.8 0.7 1.0 1.6 1.5 1.7 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 05/12/85 06:00 1.7 1.0 2.5 1.5 1.5 1.6 05/12/85 12:00 2.4 1.9 2.6 1.9 1.6 2.1 05/12/85 18:00 1.3 0.8 1.9 2.1 1.9 2.2 05/12/85 24:00 0.9 0.8 1.1 1.7 1.6 1.9 05/13/85 06:00 1.6 1.1 2.0 1.7 1.6 1.8 05/13/85 12:00 1.8 1. 6 2.0 1.9 1.8 1.9 05/13/85 18:00 1.1 0.8 1.7 1.9 1.7 2.0 05/13/85 24:00 0.9 0.8 1.2 1.6 1.5 1.7 05/14/85 06:00 1.7 1.3 2.1 1.7 1.5 1.8 05/14/85 12:00 2.0 1.7 2.2 1.9 1.7 2.0 05/14/85 18:00 1.2 0.8 1.7 1.9 1.7 2.0 05/14/85 24:00 0.8 o. 7 1.1 1.6 1.5 1.7 05/15/85 06:00 1.6 1.1 2.0 1.6 1.5 1.7 05/15/85 12:00 2.0 1.7 2.2 1.9 1.7 2.0 05/15/85 18:00 1.3 1.0 1.7 1.9 1.7 2.0 05/15/85 24:00 1.1 1.0 1.3 1.6 1.6 1.7 05/16/85 06:00 2.0 1.4 2.7 1.9 1.6 2.2 05/16/85 12:00 2.6 2.0 3.0 2.4 2.2 2.4 05/16/85 18:00 1.4 1.1 1.9 2.2 2.0 2.3 05/16/85 24:00 1.3 1.0 1.8 1.9 1.8 2.0 05/17/85 06:00 2.5 1.8 3.0 2.1 1.9 2.3 05/17/85 12:00 2.3 1.4 3.0 2.3 2.2 2.4 05/17/85 18:00 1.1 1.0 1.4 2.3 2.2 2.4 05/17/85 24:00 1.1 0.9 1.5 2.1 2.0 2.2 05/18/85 06:00 1.7 1.5 1.8 1.9 1.9 2.0 05/18/85 12:00 1.4 1.2 1.7 1.9 1.9 2.0 05/18/85 18:00 1.0 0.9 1.2 1.8 1.8 1.9 05/18/85 24:00 1.1 0.9 1.6 1.7 1.6 1.8 05/19/85 06:00 2.1 1.7 2.4 1.7 1.6 1.8 05/19/85 12:00 1.8 1.4 2.2 1.9 1.8 2.0 05/19/85 18:00 1.2 1.1 1.4 1.9 1.8 2.0 05/19/85 24:00 1.1 1.0 1.1 1.8 1.7 1.9 05/20/85 06:00 1.5 1.1 2.0 1.7 1.6 1.8 05/20/85 12:00 2.0 1.5 2.2 1.8 1.7 1.9 05/20/85 18:00 0.9 0.5 1.5 1.9 1.8 1.9 05/20/85 24:00 0. 7 0.4 1.2 1.6 1.5 1.8 05/21/85 06:00 2.5 1.3 3.4 1.6 1.5 1.7 05/21/85 12:00 2.6 1.4 3.4 2.0 1.7 2.2 05/21/85 18:00 0.9 0.6 1.3 2.1 2.0 2.2 05/21/85 24:00 0.8 0.5 1.5 1.8 1.7 2.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 PREPARED RY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 05/22/85 06:00 2.7 1.5 3.5 1.8 1.7 1.9 05/22/85 12:00 2.2 1.1 3.4 2.1 1.9 2.2 05/22/85 18:00 0.8 0.6 1.1 2. 1 2.0 2.2 05/22/85 24:00 0.8 0.5 1.5 1.9 1.7 2.0 05/23/85 06:00 2.6 1.5 3.3 1.7 1.7 1.9 05/23/85 12:00 2.0 1.1 3.1 2.0 1.9 2. 1 05/23/85 18:00 0.8 0.6 1.0 2.0 1.9 2. 1 05/23/85 24:00 0.9 0.6 1.5 1.8 1.7 2.0 05/24/85 06:00 2.4 1.5 2.9 1.8 1.7 1.9 05/24/85 12:00 1.8 1.1 2.7 2.0 1.8 2.0 05/24/85 18:00 1.0 0.9 1.1 1.9 1.9 2.0 05/24/85 24:00 1.2 1.0 1.8 1.9 1.8 1.9 05/25/85 06:00 2.0 1.7 2.1 1.8 1.7 1.9 05/25/85 12:00 1.5 1.3 1.7 1.8 1.8 1.9 05/25/85 18:00 1.1 0.9 1.3 1.8 1.8 1.9 05/25/85 24:00 1.1 0.9 1.5 1.8 1.8 1.8 05/26/85 06:00 1.6 1.4 1.8 1.8 1.7 1.8 05/26/85 12:00 1.2 0.9 1.7 1.8 1.7 1.8 05/26/85 18:00 0.9 0.8 0.9 1.7 1.7 1.8 05/26/85 24:00 1.1 0.9 1.5 1.6 1.6 1.7 05/27/85 06:00 1.8 1.5 2. 1 1.6 1.6 1.7 05/27/85 12:00 1.5 1.1 1.9 1.7 1.6 1.7 05/27/85 18:00 0.9 0.8 1.1 1.6 1.6 1.7 05/27/85 24:00 1.1 0.9 1.9 1.6 1.5 1.7 05/28/85 06:00 2.2 1.9 2.5 1.6 1.6 1.7 05/28/85 12:00 1.5 1.3 1.9 1.7 1.7 1.8 05/28/85 18:00 1.2 1. 1 1.4 1.7 1.7 1.8 05/28/85 24:00 1.4 1.1 1.6 1.8 1.7 1.8 05/29/85 06:00 1.9 1.6 2.1 1.8 1.7 1.8 05/29/85 12:00 1.3 1.1 1.6 1.8 1.8 1.8 05/29/85 18:00 1.1 1.0 1.1 1.8 1.7 1.8 05/29/85 24:00 1.2 1.0 1.5 1.8 1.7 1.8 05/30/85 06:00 1.6 1.4 1.8 1.7 1.6 1.8 05/30/85 12:00 1.5 1.2 1.8 1.7 1.6 1.7 05/30/85 18:00 1.2 1.2 1.3 1.7 1.6 1.8 05/30/85 24:00 1.4 1.2 1.6 1.8 1.7 1.8 05/31/85 06:00 1.5 1.4 1.7 1.7 1.6 1.8 05/31/85 12:00 1.5 1.4 1.7 1.7 1.6 1.7 05/31/85 18:00 1.3 1.3 1.4 1.8 1.7 1.8 05/31/85 24:00 1.3 1.2 1.4 1.8 1.7 1.8 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CF~EL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 06/01/85 06:00 1.6 1.4 1.7 1.7 1.7 1.7 06/01/85 12:00 1.3 1.1 1.5 1.7 1.7 1.7 06/01/85 18:00 1.1 1.1 1.2 1.7 1.7 1.7 06/01/85 24:00 1.4 1.1 1.8 1.7 1.6 1.8 06/02/85 06:00 2.1 1.8 2.4 1.6 1.6 1.7 06/02/85 12:00 1.5 1.4 ·1.8 1.7 1.7 1.8 06/02/85 18:00 1.3 1.2 1.4 1.9 1.8 1.9 06/02/85 24:00 1.4 1.2 1.9 1.9 1.8 2.0 06/03/85 06:00 2.0 1.8 2.2 1.8 1.8 1.9 06/03/85 12:00 1.6 1.5 1.7 1.8 1.8 1.9 06/03/85 18:00 1.6 1.5 1.7 1.9 1.8 2.0 06/03/85 24:00 1.8 1.7 2.0 2.0 1.9 2.0 06/04/85 06:00 2.1 2.0 2.1 2.0 1.9 2.0 06/04/85 12:00 1.7 1.5 2.0 2.0 2.0 2.1 06/04/85 18:00 1.5 1.4 1.5 2.1 2.0 2.1 06/04/85 24:00 1.5 1.3 1.8 2.0 2.0 2.1 06/05/85 06:00 2.0 1.7 2.2 1.9 1.9 2.0 06/05/85 12:00 1.5 1.4 1.8 2.0 1.9 2.0 06/05/85 18:00 1.4 1.3 1.4 2.0 1.9 2.0 06/05/85 24:00 1.5 1.3 2.1 1.9 1.8 2.0 06/06/85 06:00 2.4 2.1 2.5 1.9 1.8 1.9 06/06/85 12:00 1.8 1.5 2.3 2.0 1.8 2 .I 06/06/85 18:00 1.3 1.2 1.5 2.1 2.0 2.2 06/06/85 24:00 1.4 1.1 2.1 2.1 2.0 2.1 06/07/85 06:00 2.6 2.2 2.8 1.9 1.9 2.0 06/07/85 12:00 2.1 1.6 2.7 2.0 1.9 2.1 06/07/85 18:00 1.6 1.5 1.6 2.2 2.0 2.3 06/07/85 24:00 1.8 1.5 2.1 2.3 2.2 2.3 06/08/85 06:00 2.3 2.1 2.5 2.2 2.2 2.3 06/08/85 12:00 2.1 1.8 2.5 2.2 2.1 2.2 06/08/85 18:00 1.6 1.5 1.8 2.3 2.2 2.3 06/08/85 24:00 1.8 1.5 2.3 2.3 2.3 2.4 06/09/85 06:00 2.7 2.4 2.9 2.3 2.2 2.3 06/09/85 12:00 2.3 1.9 2.6 2.3 2.2 2.3 06/09/85 18:00 1.8 1.6 1.9 2.4 2.3 2.4 06/09/85 24:00 1.8 1.5 2.3 2.4 2.4 2.5 06/10/85 06:00 2.8 2.4 3.1 2.4 2.4 2.4 06/10/85 12:00 2.5 2.0 3.0 2.4 2.4 2.4 06/10/85 18:00 1.6 1.4 2.0 2.5 2.4 2.5 06/10/85 24:00 1.9 1.4 2.8 2.5 2.4 2.5 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 06/11/85 06:00 2.9 2.6 3.1 2.5 2.5 2.5 06/11/85 12:00 2.4 2.0 2.6 2.5 2.4 2.5 06/11/85 18:00 1.9 1.8 2.1 2.5 2.5 2.5 06/11/85 24:00 2. 1 1.8 2.8 2.5 2.5 2.6 06/12/85 06:00 3.5 2.8 3.9 2.5 2.5 2.6 06/12/85 12:00 3 .1 2.5 3.8 2.6 2.5 2.7 06/12/85 18:00 2.1 2.0 2.5 2.8 2.6 2.8 06/12/85 24:00 2.3 2.0 2.9 2.9 2.8 2.9 06/13/85 06:00 3.2 2.9 3.4 2.9 2.9 2.9 06/13/85 12:00 2.9 2.5 3.3 2.9 2.8 3.0 06/13/85 18:00 2.2 2.0 2.5 2.9 2.9 3.0 06/13/85 24:00 2.3 2.0 2.7 2.9 2.9 3.0 06/14/85 06:00 3.6 2.7 4.3 2.9 2.9 3.0 06/14/85 12:00 3.2 2.6 4.0 2.9 2.9 3.0 06/14/85 18:00 2.3 2.1 2.6 2.9 2.9 3.0 06/14/85 24:00 2.3 2.1 2.9 3. 1 3.0 3.1 06/15/85 06:00 3.6 2.8 4.2 3.0 3.0 3. 1 06/15/85 12:00 3.3 2.5 4.2 3.0 3.0 3.1 06/15/85 18:00 2.2 2.0 2.5 3.1 3.0 3.1 06/15/85 24:00 2.2 2.0 2.9 3.2 3.1 3.2 06/16/85 06:00 4.1 2.9 4.5 3.1 3.1 3.2 06/16/85 12:00 3.4 2.5 4.4 3.1 3.0 3.1 06/16/85 18:00 2.4 2.3 2.6 3.1 3.1 3.2 06/16/85 24:00 2.7 2.3 3.5 3.3 3.2 3.3 06/17/85 06:00 3.8 3.5 4.2 3.3 3.2 3.3 06/17/85 12:00 3.1 2.5 3.6 3.3 3.2 3.3 06/17/85 18:00 2.1 2.0 2.5 3.3 3.2 3.3 06/17/85 24:00 2.4 2.0 2.8 3.3 3.2 3.3 06/18/85 06:00 2.9 2.7 3.0 3.2 3.1 3.3 06/18/85 12:00 2.9 2.7 3.0 3.0 3.0 3.1 06/18/85 18:00 2.6 2.5 2.7 3.0 2.9 3.0 06/18/85 24:00 2.8 2.5 3.6 3.0 2.9 3.0 06/19/85 06:00 4.4 3.7 4.8 3.0 3.0 3.1 06/19/85 12:00 3.8 3.1 4.6 3.2 3. 1 3.3 06/19/85 18:00 2.8 2.6 3.1 3.4 3.2 3.5 06/19/85 24:00 2.8 2.6 3.4 3.5 3.4 3.6 06/20/85 06:00 3.8 3.4 4.1 3.6 3.5 3.6 06/20/85 12:00 3.3 2.9 3.8 3.5 3.4 3.5 06/20/85 18:00 2.7 2.6 2.9 3.4 3.4 3.4 06/20/85 24:00 2.8 2.6 3.1 3.4 3.4 3.5 f'-'RT /1(17 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 06/21/85 06:00 3.7 3.1 4.3 3.4 3.4 3.5 06/21/85 12:00 3.7 3.2 4.3 3.4 3.4 3.5 06/21/85 18:00 2.9 2.8 3.2 3.4 3.4 3.5 06/21/85 24:00 3.0 2.7 3.5 3.5 3.4 3.5 06/22/85 06:00 4. 1 3.4 4.4 3.5 3.4 3.6 06/22/85 12:00 3.9 3.3 4.3 3.5 3.5 3.6 06/22/85 18:00 2.8 2.5 3.3 3.5 3.5 3.6 06/22/85 24:00 3.0 2.6 4.0 3.6 3.5 3.7 06/23/85 06:00 5.2 4.1 5.7 3.6 3.6 3.7 06/23/85 12:00 4.6 3.6 5.6 3.7 3.6 3.8 06/23/85 18:00 3.1 2.8 3.6 3.9 3.7 4.0 06/23/85 24:00 3.2 2.8 3.7 4.1 3.9 4.2 06/24/85 06:00 4.1 3.6 4.3 4.1 4.0 4.2 06/24/85 12:00 3.8 3.4 4.2 4.0 3.9 4.0 06/24/85 18:00 3.1 3.0 3.4 3.9 3.8 3.9 06/24/85 24:00 3.1 2.9 3.5 3.9 3.8 3.9 06/25/85 06:00 4.2 3.5 4.5 3.8 3.7 3.9 06/25/85 12:00 4.2 3.7 4.5 3.8 3.7 3.8 06/25/85 18:00 3.3 3.2 3.7 3.8 3.8 3.9 06/25/85 24:00 3.4 3.2 3.8 3.9 3.8 4.0 06/26/85 06:00 4.0 3.8 4.1 4.0 3.9 4.0 06/26/85 12:00 3.8 3.6 4.0 3.9 3.9 4.0 06/26/85 18:00 3.5 3.4 3.6 3.9 3.9 3.9 06/26/85 24:00 3.6 3.4 4.1 3.9 3.8 4.0 06/27/85 06:00 4.9 4.1 5.7 4.0 3.9 4.0 06/27/85 12:00 5.0 4.1 5.7 4.0 3.9 4.1 06/27/85 18:00 3.5 3.2 4.0 4.2 4.0 4.2 06/27/85 24:00 3.5 3.2 4.6 4.3 4.2 4.4 06/28/85 06:00 5.9 4.6 6.4 4.4 4.3 4.5 06/28/85 12:00 5.3 4.2 6.4 4.4 4.4 4.5 06/28/85 18:00 3.7 3.5 4.2 4.5 4.4 4.7 06/28/85 24:00 4.0 3.4 5.0 4.7 4.6 4.8 06/29/85 06:00 5.9 5.0 6.3 4.7 4.6 4.8 06/29/85 12:00 5.3 4.3 6.1 4.6 4.6 4.7 06/29/85 18:00 3.9 3.6 4.3 4.8 4.7 5.0 06/29/85 24:00 4.0 3.6 4.9 5.0 4.9 5.1 06/30/85 06:00 5.9 4.9 6.2 4.8 4.7 4.9 06/30/85 12:00 5.3 4.4 6.1 4.7 4.6 4.8 06/30/85 18:00 4.2 4.0 4.5 4.9 4.8 5.1 06/30/85 24:00 4.4 4.1 5.1 5.1 4.9 5.1 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX -- 07/01/85 06:00 6.1 5.2 6.4 4.9 4.8 5.0 07/01/85 12:00 5.2 4.5 6.2 4.9 4.8 5.1 07/01/85 18:00 4.6 4.2 4.9 5.2 5. 1 5.3 07/01/85 24:00 4.9 4.8 4.9 5.2 5.1 5.6 07/02/85 06:00 5.4 4.9 5.8 5.1 5.0 5.2 07/02/85 12:00 5.0 4.5 5.6 5.1 5.0 5.2 07/02/85 18:00 4.5 4.3 4.5 5.3 5.1 5.3 07/02/85 24:00 4.5 4.3 4.7 5.1 5.0 5.2 07/03/85 06:00 5.0 4.6 5.1 4.9 4.8 5.0 07/03/85 12:00 4.6 4.4 5.0 4.9 4.8 4.9 07/03/85 18:00 4.4 4.3 4.5 4.9 4.9 5.0 07/03/85 24:00 4.4 4.3 4.6 4.9 4.8 4.9 07/04/85 06:00 4.7 4.6 4.7 4.8 4.7 4.8 07/04/85 12:00 4.6 4.5 4.7 4.7 4.7 4.8 07/04/85 18:00 4.4 4.3 4.5 4.8 4.7 4.8 07/04/85 24:00 4.5 4.3 5.0 4.8 4.7 4.8 07/05/85 06:00 5.6 5.0 5.9 4.7 4.7 4.8 07/05/85 12:00 5.1 4.5 5.8 4.9 4.7 5.0 07/05/85 18:00 4.4 4.2 4.6 5.1 5.0 5.2 07/05/85 24:00 4.5 4.1 5.4 5.1 5.0 5.2 07/06/85 06:00 6.2 5.4 6.4 5.0 4.9 5.0 07/06/85 12:00 5.5 4.8 6.3 5.1 4.9 5.2 07/06/85 18:00 4.4 4.3 4.8 5.4 5.2 5.5 07/06/85 24:00 4.6 4.3 5.5 5.4 5.3 5.5 07/07/85 06:00 6.4 5.5 6.7 5.2 5.1 5.3 07/07/85 12:00 6.2 5.8 6.5 5.3 5.1 5.4 07/07/85 18:00 5.5 5.3 5.8 5.6 5.4 5.8 07/07/85 24:00 5.4 5.3 5.4 5.8 5.7 5.8 07/08/85 06:00 5.4 5.4 5.6 5.8 5.7 5.8 07/08/85 12:00 5.4 4.9 5.6 5.7 5.6 5.7 07/08/85 18:00 4.8 4.7 5.0 5.6 5.5 5.6 07/08/85 24:00 4.9 4.7 5.3 5.5 5.4 5.5 07/09/85 06:00 5.4 5.3 5.5 5.3 5.3 5.4 07/09/85 12:00 5.4 5.1 5.5 5.3 5.3 5.4 07/09/85 18:00 5.0 4.9 5.1 5.4 5.3 5.5 07/09/85 24:00 5.1 4.9 5.8 5.4 5.4 5.5 07/10/85 06:00 6.4 5.7 6.7 5.4 5.3 5.5 07/10/85 12:00 6.0 5.4 6.6 5.5 5.4 5.7 07/10/85 18:00 5.0 4.8 5.5 5.8 5.7 5.9 07/10/85 24:00 5.0 4.7 5.7 5.8 5.7 5.9 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 8 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 07/11/85 06:00 6.3 5.8 6.6 5.6 5.6 5.7 07/11/85 12:00 5.8 5.2 6.4 5.6 5.6 5.7 07/11/85 18:00 4.9 4.8 5.3 5.8 5.7 5.8 07/11/85 24:00 5.2 4.8 6.2 5.7 5.6 5.8 07/12/85 06:00 6.3 6.2 6.4 5.6 5.5 5.7 07/12/85 12:00 6.1 5.9 6.2 5.6 5.5 5.8 07/12/85 18:00 5.8 5.6 6.0 5.9 5.7 5.9 07/12/85 24:00 5.8 5.6 6.4 6.0 5.9 6.1 07/13/85 06:00 7.2 6.4 7.4 6.0 6.0 6.1 07/13/85 12:00 6.8 6.3 7.3 6.2 6.1 6.4 07/13/85 18:00 6.1 5.9 6.3 6.5 6.3 6.6 07/13/85 24:00 6.2 5.9 6.8 6.6 6.5 6.7 07/14/85 06:00 7.3 6.7 7.6 6.6 6.5 6.6 07/14/85 12:00 7.0 6.5 7.5 6.6 6.5 6.7 07/14/85 18:00 6.1 5.9 6.5 6.7 6.6 6.8 07/14/85 24:00 6.2 5.9 6.9 6.8 6.7 6.9 07/15/85 06:00 7.4 6.8 7.7 6.7 6.7 6.7 07/15/85 12:00 7.1 6.5 7.7 6.7 6.6 6.8 07/15/85 18:00 6.0 5.8 6.5 6.9 6.7 7.0 07/15/85 24:00 6.2 5.8 6.9 6.9 6.7 6.9 07/16/85 06:00 7.5 6.9 8.0 6.7 6.7 6.8 07/16/85 12:00 7.2 6.7 7.9 6.7 6.7 6.8 07/16/85 18:00 6.3 6. 1 6.7 6.9 6.8 7.0 07/16/85 24:00 6.3 6.1 6.7 7.0 6.9 7.0 07/17/85 06:00 7.2 6.7 7.4 6.8 6.7 6.9 07/17/85 12:00 6.9 6.6 7.2 6.8 6.7 6.8 07/17/85 18:00 6.5 6.3 6.7 6.9 6.8 6.9 07/17/85 24:00 6.5 6.3 7.2 6.9 6.8 7.0 07/18/85 06:00 8.1 7.2 8.4 6.8 6.8 6.9 07/18/85 12:00 7.7 7.1 8.4 7.0 6.8 7.1 07/18/85 18:00 6.9 6.8 7.1 7.3 7.1 7.4 07/18/85 24:00 7.0 6.8 7.3 7.4 7.3 7.5 07/19/85 06:00 7.6 7.3 7.8 7.3 7.3 7.4 07/19/85 12:00 7.6 7.2 7.8 7.3 7.3 7.4 07/19/85 18:00 7.1 7.1 7.2 7.4 7.3 7.5 07/19/85 24:00 7.2 7.1 7.3 7.5 7.4 7.5 07/20/85 06:00 7.2 7.1 7.3 7.4 7.3 7.4 07/20/85 12:00 7.0 6.7 7.2 7.3 7.3 7.4 07/20/85 18:00 6.6 6.4 6.8 7.3 7.2 7.3 07/20/85 24:00 6.6 6.4 7.0 7.2 7.1 7.3 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 9 PREPARED BY DRYDEN & LARL'E DATA FILE TBRTTC.POD 23-AUG-85 TREE BAR REACH START TIME 05/02/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 07/21/85 06:00 7.6 7.0 8.0 7.0 6.9 7. 1 07/21/85 12:00 7.5 6.9 8.0 7. 1 7.0 7.3 07/21/85 18:00 6.7 6.5 6.9 7.3 7.2 7.3 07/21/85 24:00 6.6 6.4 6.9 7.3 7.2 7.3 07/22/85 06:00 7.2 6.8 7.4 7. 1 7.0 7.2 07/22/85 12:00 7.1 6.8 7.4 7.1 7.0 7.1 07/22/85 18:00 6.6 6.6 6.8 7. 1 7.1 7.2 07/22/85 24:00 6.6 6.5 6.8 7.1 7.0 7.2 07/23/85 06:00 7.2 6.7 7.5 7.0 7.0 7.0 07/23/85 12:00 7.1 6.8 7.4 7.0 6.9 7.1 07/23-/85 18:00 6.6 6.6 6.8 7.1 7.0 7.2 07/23/85 24:00 6.6 6.4 6.9 7.1 7.0 7.2 07/24/85 06:00 7.3 6.8 7.5 7.0 6.9 7.0 07/24/85 12:00 7.2 6.9 7.4 7.0 6.9 7.0 07/24/85 18:00 6.8 6.7 6.9 7.1 7.0 7.1 07/24/85 24:00 6.8 6.7 7.2 7.1 7.1 7.2 07/25/85 06:00 7.7 7.1 8.0 7.1 7.1 7.1 07/25/85 12:00 7.2 6.5 7.9 7.2 7.0 7.3 07/25/85 18:00 6.3 6.2 6.5 7.3 7.2 7.4 07/25/85 24:00 6.5 6.2 7.2 7.2 7.1 7.3 07/26/85 06:00 7.8 7.2 8.2 7.0 6.9 7.2 07/26/85 12:00 7.3 6.8 7.9 7.0 6.9 7.2 07/26/85 18:00 7.0 6.7 7.3 7.2 7.1 7.3 07/26/85 24:00 7.1 6.8 7.6 7.3 7.3 7.4 D-BL/107 D-BL/107 Attachment III North Fork Bradley River Water Quality Data May 3, 1985 through September 3, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page l PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 05/02/85 24:00 3.2 3.20 0 1.5 DAILY AVG VALUES 3.2 3.20 0 1.5 05/03/85 06:00 3.2 3.20 0 1.5 05/03/85 12:00 2.8 2.80 0 1.5 05/03/85 18:00 2.8 2.80 0 2.0 05/03/85 24:00 3.2 3.20 0 1.5 DAILY AVG VALUES 3.0 3.00 0 1.6 05/04/85 06:00 2.8 2.80 0 1.5 05/04/85 12:00 2.8 2.80 0 1.5 05/04/85 18:00 2.8 2.80 0 2.0 05/04/85 24:00 4.4 4.40 0 1.5 DAILY AVG VALUES 3.2 3.20 0 1.6 05/05/85 06:00 4.4 4.40 0 1.5 05/05/85 12:00 4.0 4.00 0 1.5 05/05/85 18:00 4.0 4.00 0 2.0 05/05/85 24:00 4.4 4.40 0 1.5 DAILY AVG VALUES 4.2 4.20 0 1.6 05/06/85 06:00 4.8 4.80 0 1.5 05/06/85 12:00 4.4 4.40 0 1.5 05/06/85 18:00 5.6 5.60 0 2.0 05/06/85 24:00 9.2 9.20 0 1.0 DAILY AVG VALUES 6.0 6.00 0 1.5 05/07/85 06:00 8.8 8.80 0 1.0 05/07/85 12:00 7.6 7.60 0 1.5 05/07/85 18:00 7.2 7.20 0 2.0 05/07/85 24:00 7.2 7.20 0 1.5 DAILY AVG VALUES 7.7 7.70 0 1.5 05/08/85 06:00 7.2 7.20 0 1.5 05/08/85 12:00 6.8 6.80 0 1.5 05/08/85 18:00 6.8 6.80 0 2.0 05/08/85 24:00 7.2 7.20 0 2.0 DAILY AVG VALUES 7.0 7.00 0 1.8 05/09/85 06:00 7.2 7.20 0 2.0 05/09/85 12:00 6.8 6.80 0 1.5 05/09/85 18:00 6.8 6.80 0 2.0 05/09/85 24:00 6.4 6.40 0 2.0 DAILY AVG VALUES 6.8 6.80 0 1.9 05/10/85 06:00 6.0 6.00 0 1.5 05/10/85 12:00 6.0 6.00 0 1.5 05/10/85 18:00 5.6 5.60 0 2.0 05/10/85 24:00 5.6 5.60 0 2.0 DAILY AVG VALUES 5.8 5.80 0 l.8 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 05/11/85 06:00 5.2 5.20 0 1.5 05/11/85 12:00 5.2 5.20 0 1.5 05/11/85 18:00 5.2 5.20 0 2.5 05/11/85 24:00 5.6 5.60 0 2.0 DAILY AVG VALUES 5.3 5.30 0 1.9 05/12/85 06:00 5.2 5.20 0 1.5 05/12/85 12:00 5.2 5.20 0 2.0 05/12/85 18:00 5.2 5.20 0 2.5 05/12/85 24:00 5.2 5.20 0 2.0 DAILY AVG VALUES 5.2 5.20 0 2.0 05/13/85 06:00 4.8 4.80 0 1.5 05/13/85 12:00 4.8 4.80 0 2.0 05/13/85 18:00 5.2 5.20 0 2.5 05/13/85 24:00 5.2 5.20 0 2.0 DAILY AVG VALUES 5.0 5.00 0 2.0 05/14/85 06:00 5.2 5.20 0 1.5 05/14/85 12:00 5.2 5.20 0 1.5 05/14/85 18:00 5.2 5.20 0 2.5 05/14/85 24:00 5.2 5.20 0 2.0 DAILY AVG VALUES 5.2 5.20 0 1.9 05/15/85 06:00 4.8 4.80 0 2.0 05/15/85 12:00 4.8 4.80 0 2.0 05/15/85 18:00 5.2 5.20 0 2.5 05/15/85 24:00 6.8 6.80 0 2.0 DAILY AVG VALUES 5.4 5.40 0 2.1 05/16/85 06:00 7.6 7.60 0 2.0 05/16/85 12:00 7.2 7.20 0 2.0 05/16/85 18:00 8.8 8.80 0 2.5 05/16/85 24:00 12.4 12.40 0 1.5 DAILY AVG VALUES 9.0 9.00 0 2.0 05/17/85 06:00 12.4 12.lo0 0 1.5 05/17/85 12:00 12.0 12.00 0 1.5 05/17/85 18:00 12.4 12.40 0 2.0 05/17/85 24:00 12.0 12.00 0 1.5 DAILY AVG VALUES 12.2 12.20 0 1.6 05/18/85 06:00 11.2 11.20 0 1.5 05/18/85 12:00 10.8 10.80 0 2.0 05/18/85 18:00 12.0 12.00 0 2.5 05/18/85 24:00 13.2 13.20 0 2.0 DAILY AVG VALUES 11.8 11.80 0 2.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 05/19/85 06:00 12.4 12.40 0 1.5 05/19/85 12:00 12.0 12.00 0 2.0 05/19/85 18:00 11.2 11.20 0 2.0 05/19/85 24:00 11.2 11.20 0 2.0 DAILY AVG VALUES 11.7 11.70 0 1.9 05/20/85 06:00 10.8 10.80 0 1.5 05/20/85 12:00 10.4 10.40 0 1.5 05/20/85 18:00 10.8 10.80 0 3.0 05/20/85 24:00 13.6 13.60 0 2.0 DAILY AVG VALUES 11.4 11.40 0 2.0 05/21/85 06:00 13.6 13.60 0 1.5 05/21/85 12:00 12.8 12.80 0 1.5 05/21/85 18:00 13.6 13.60 0 3.0 05/21/85 24:00 17.6 17.60 0 1.5 DAILY AVG VALUES 14.4 14.40 0 1.9 05/22/85 06:00 17.2 17.20 0 1.5 05/22/85 12:00 16.0 16.00 0 1.5 05/22/85 18:00 17.6 17.60 0 2.5 05/22/85 24:00 21.6 21.60 0 1.5 DAILY AVG VALUES 18. 1 18.10 0 1.8 05/23/85 06:00 20.4 20.40 0 1.5 05/23/85 12:00 19.2 19.20 0 1.5 05/23/85 18:00 19.6 19.60 0 2.5 05/23/85 24:00 23.6 23.60 0 1.5 DAILY AVG VALUES 20.7 20.70 0 1.8 05/24/85 06:00 24.4 24.40 0 1.5 05/24/85 12:00 24.0 24.00 0 2.0 05/24/85 18:00 28.0 28.00 0 2.0 05/24/85 24:00 33.2 33.20 0 1.5 DAILY AVG VALUES 27.4 27.40 0 1.8 05/25/85 06:00 36.0 36.00 0 1.5 05/25/85 12:00 38.0 38.00 0 1.5 05/25/85 18:00 39.6 39.60 0 2.0 05/25/85 24:00 40.8 40.80 0 1.5 DAILY AVG VALUES 38.6 38.60 0 1.6 05/26/85 06:00 38.8 38.80 0 2.0 05/26/85 12:00 36.4 36.40 0 2.0 05/26/85 18:00 35.6 35.60 0 2.5 05/26/85 24:00 38.4 38.40 0 2.0 DAILY AVG VALUES 37.3 37.30 0 2.1 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 05/27/85 06:00 38.8 38.80 0 2.0 05/27/85 12:00 36.0 36.00 0 2.0 05/27/85 18:00 38.4 38.40 0 3.0 05/27/85 24:00 42.0 42.00 0 2.0 DAILY AVG VALUES 38.8 38.80 0 2.3 05/28/85 06:00 45.2 45.20 0 2.0 05/28/85 12:00 45.2 45.20 0 2.0 05/28/85 18:00 47.2 47.20 0 2.5 05/28/85 24:00 47.6 47.60 0 2.0 DAILY AVG VALUES 46.3 46.30 0 2.1 05/29/85 06:00 44.8 44.80 0 2.0 05/29/85 12:00 44.0 44.00 0 2.0 05/29/85 18:00 44.0 44.00 0 2.5 05/29/85 24:00 44.4 44.40 0 2.0 DAILY AVG VALUES 44.3 44.30 0 2.1 05/30/85 06:00 43.2 43.20 0 2.0 05/30/85 12:00 42.4 42.40 0 2.5 05/30/85 18:00 46.0 46.00 0 2.5 05/30/85 24:00 46.0 46.00 0 2.5 DAILY AVG VALUES 44.4 44.40 0 2.4 05/31/85 06:00 46.0 46.00 0 2.5 05/31/85 12:00 47.2 47.20 0 2.5 05/31/85 18:00 46.0 46.00 0 3.0 05/31/85 24:00 44.0 44.00 0 2.5 DAILY AVG VALUES 45.8 45.80 0 2.6 06/01/85 06:00 42.0 42.00 0 2.5 06/01/85 12:00 39.6 39.60 0 2.5 06/01/85 18:00 40.0 40.00 0 4.0 06/01/85 24:00 39.2 39.20 0 3.0 DAILY AVG VALUES 40.2 40.20 0 3.0 06/02/85 06:00 37.6 37.60 0 2.5 06/02/85 12:00 35.6 35.60 0 3.0 06/02/85 18:00 36.4 36.40 0 3.5 06/02/85 24:00 40.0 40.00 0 3.0 DAILY AVG VALUES 37.4 37.40 0 3.0 06/03/85 06:00 42.0 42.00 0 3.0 06/03/85 12:00 47.2 47.20 0 3.0 06/03/85 18:00 52.8 52.80 0 3.0 06/03/85 24:00 56.8 56.80 0 2.5 DAILY AVG VALUES 49.7 49.70 0 2.9 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 06/04/85 06:00 54.0 54.00 0 2.5 06/04/85 12:00 50.0 50.00 0 2.5 06/04/85 18:00 49.2 49.20 0 3.5 06/04/85 24:00 48.4 48.40 0 2.5 DAILY AVG VALUES 50.4 50.40 0 2.8 06/05/85 06:00 46.4 46.40 0 2.5 06/05/85 12:00 44.8 44.80 0 3.0 06/05/85 18:00 44.8 44.80 0 4.5 06/05/85 24:00 45.2 45.20 0 3.0 DAILY AVG VALUES 45.3 45.30 0 3.3 06/06/85 06:00 42.4 42.40 0 2.0 06/06/85 12:00 40.4 40.40 0 2.5 06/06/85 18:00 39.6 39.60 0 5.0 06/06/85 24:00 40.4 40.40 0 3.5 DAILY AVG VALUES 40.7 40.70 0 3.3 06/07/85 06:00 39.2 39.20 0 3.0 06/07/85 12:00 37.6 37.60 0 3.0 06/07/85 18:00 36.8 36.80 0 4.0 06/07/85 24:00 36.8 36.80 0 3.5 DAILY AVG VALUES 37.6 37.60 0 3.4 06/08/85 06:00 35.6 35.60 0 2.5 06/08/85 12:00 33.6 33.60 0 3.0 06/08/85 18:00 34.4 34.40 0 4.5 06/08/85 24:00 36.0 36.00 0 4.0 DAILY AVG VALUES 34.9 34.90 0 3.5 06/09/85 06:00 34.8 34.80 0 3.0 06/09/85 12:00 32.4 32.40 0 3.5 06/09/85 18:00 32.8 32.80 0 5.0 06/09/85 24:00 34.8 34.80 0 4.5 DAILY AVG VALUES 33.7 33.70 0 4.0 06/10/85 06:00 34.8 34.80 0 2.5 06/10/85 12:00 33.2 33.20 0 3.0 06/10/85 18:00 32.8 32.80 0 5.0 06/10/85 24:00 31.6 31.60 0 4.0 DAILY AVG VALUES 33.1 33.10 0 3.6 06/11/85 06:00 30.4 30.40 0 3.5 06/11/85 12:00 29.2 29.20 0 3.5 06/11/85 18:00 31.2 31.20 0 6.0 06/11/85 24:00 35.6 35.60 0 5.0 DAILY AVG VALUES 31.6 31.60 0 4.5 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 PREPARED BY DRYDEN & LARVE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 06/12/85 06:00 34.4 34.40 0 3.5 06/12/85 12:00 33.2 33.20 0 4.0 06/12/85 18:00 33.2 33.20 0 5.0 06/12/85 24:00 35.2 35.20 0 4.5 DAILY AVG VALUES 34.0 34.00 0 4.3 06/13/85 06:00 34.8 34.80 0 3.0 06/13/85 12:00 34.0 34.00 0 3.5 06/13/85 18:00 34.0 34.00 0 6.0 06/13/85 24:00 36.8 36.80 0 5.0 DAILY AVG VALUES 34.9 34.90 0 4.4 06/14/85 06:00 36.8 36.80 0 3.5 06/14/85 12:00 34.0 34.00 0 3.5 06/14/85 18:00 33.6 33.60 0 6.0 06/14/85 24:00 38.0 38.00 0 5.0 DAILY AVG VALUES 35.6 35.60 0 4.5 06/15/85 06:00 36.8 36.80 0 3.0 06/15/85 12:00 35.6 35.60 0 3.5 06/15/85 18:00 35.6 35.60 0 6.5 06/15/85 24:00 38.4 38.40 0 5.0 DAILY AVG VALUES 36.6 36.60 0 4.5 06/16/85 06:00 36.8 36.80 0 3.5 06/16/85 12:00 34.8 34.80 0 4.0 06/16/85 18:00 34.0 34.00 0 6.0 06/16/85 24:00 35.2 35.20 0 4.5 DAILY AVG VALUES 35.2 35.20 0 4.5 06/17/85 06:00 34.4 34.40 0 2.5 06/17/85 12:00 31.6 31.60 0 3.5 06/17/85 18:00 32.8 32.80 0 4.0 06/17/85 24:00 37.2 37.20 0 4.0 DAILY AVG VALUES 34.0 34.00 0 3.5 06/18/85 06:00 36.4 36.40 0 3.5 06/18/85 12:00 34.8 34.80 0 4.0 06/18/85 18:00 36.0 36.00 0 6.5 06/18/85 24:00 40.0 40.00 0 5.0 DAILY AVG VALUES 36.8 36.80 0 4.8 06/19/85 06:00 39.6 39.60 0 3.5 06/19/85 12:00 37.6 37.60 0 4.0 06/19/85 18:00 37.6 37.60 0 5.5 06/19/85 24:00 38.0 38.00 0 4.5 DAILY AVG VALUES 38.2 38.20 0 4.4 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 PREPARED BY DRYDEN & LARUE DATA FILE NFBF.C.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 06/20/85 06:00 36.8 36.80 0 3.5 06/20/85 12:00 35.6 35.60 0 3.5 06/20/85 18:00 34.0 34.00 0 5.0 06/20/85 24:00 35.2 35.20 0 5.0 DAILY AVG VALUES 35.4 35.40 0 4.3 06/21/85 06:00 33.6 33.60 0 3.5 06/21/85 12:00 32.4 32.40 0 4.0 06/21/85 18:00 31.6 31.60 0 5.5 06/21/85 24:00 34.0 34.00 0 5.5 DAILY AVG VALUES 32.9 32.90 0 4.6 06/22/85 06:00 33.2 33.20 0 3.5 06/22/85 12:00 32.4 32.40 0 4.0 06/22/85 18:00 32.4 32.40 0 7.5 06/22/85 24:00 37.6 37.60 0 6.5 DAILY AVG VALUES 33.9 33.90 0 5.4 06/23/85 06:00 36.8 36.80 0 3.5 06/23/85 12:00 35.2 35.20 0 4.0 06/23/85 18:00 33.2 33.20 0 5.5 06/23/85 24:00 34.0 34.00 0 5.0 DAILY AVG VALUES 34.8 34.80 0 4.5 06/24/85 06:00 33.6 33.60 0 3.5 06/24/85 12:00 32.0 32.00 0 3.5 06/24/85 18:00 30.4 30.40 0 6.0 06/24/85 24:00 31.6 31.60 0 5.5 DAILY AVG VALUES 31.9 31.90 0 4.6 06/25/85 06:00 31.2 31.20 0 4.0 06/25/85 12:00 30.4 30.40 0 4.5 06/25/85 18:00 31.2 31.20 0 5.5 06/25/85 24:00 32.4 32.40 0 5.0 DAILY AVG VALUES 31.3 31.30 0 4.8 06/26/85 06:00 32.4 32.40 0 4.5 06/26/85 12:00 31.6 31.60 0 4.5 06/26/85 18:00 32.4 32.40 0 7.0 06/26/85 24:00 38.0 38.00 0 7.0 DAILY AVG VALUES 33.6 33.60 0 5.8 06/27/85 06:00 38.0 38.00 0 4.0 06/27/85 12:00 36.8 36.80 0 4.5 06/27/85 18:00 37.2 37.20 0 8.5 06/27/85 24:00 41.6 41.60 0 7.0 DAILY AVG VALUES 38.4 38.40 0 6.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 8 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 06/28/85 06:00 42.0 42.00 0 4.5 06/28/85 12:00 40.0 40.00 0 5.5 06/28/85 18:00 42.0 42.00 0 8.0 06/28/85 24:00 45.6 45.60 0 6.5 DAILY AVG VALUES 42.4 42.40 0 6.1 06/29/85 06:00 44.4 44.40 0 4.5 06/29/85 12:00 42.4 42.40 0 5.0 06/29/85 18:00 43.6 43.60 0 8.0 06/29/85 24:00 47.6 47.60 0 6.5 DAILY AVG VALUES 44.5 44.50 0 6.0 06/30/85 06:00 46.8 46.80 0 5.0 06/30/85 12:00 46.8 46.80 0 5.5 06/30/85 18:00 48.4 48.40 0 8.0 06/30/85 24:00 50.0 50.00 0 6.5 DAILY AVG VALUES 48.0 48.00 0 6.3 07/01/85 06:00 49.6 49.60 0 5.5 07/01/85 12:00 50.4 50.40 0 6.0 07/01/85 18:00 53.2 53.20 0 7.0 07/01/85 24:00 56.8 56.80 0 6.0 DAILY AVG VALUES 52.5 52.50 0 6.1 07/02/85 06:00 54.4 54.40 0 5.0 07/02/85 12:00 52.0 52.00 0 5.0 07/02/85 18:00 51.2 51.20 0 6.0 07/02/85 24:00 51.6 51.60 0 5.5 DAILY AVG VALUES 52.3 52.30 0 5.4 07/03/85 06:00 50.4 50.40 0 5.0 07/03/85 12:00 49.6 49.60 0 5.0 07/03/85 18:00 50.4 50.40 0 5.5 07/03/85 24:00 50.0 50.00 0 5.5 DAILY AVG VALUES 50.1 50.10 0 5.3 07/04/85 06:00 50.0 50.00 0 5.0 07/04/85 12:00 47.6 47.60 0 5.0 07/04/85 18:00 47.6 47.60 0 7.5 07/04/85 24:00 48.8 48.80 0 6.5 DAILY AVG VALUES 48.5 48.50 0 6.0 07/05/85 06:00 48.0 48.00 0 4.5 07/05/85 12:00 46.8 46.80 0 5.0 07/05/85 18:00 46.0 46.00 0 8.5 07/05/85 24:00 47.6 47.60 0 7.5 DAILY AVG VALUES 47.1 47.10 0 6.4 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 9 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 07/06/85 06:00 47.2 47.20 0 5.0 07/06/85 12:00 45.2 45.20 0 5.5 07/06/85 18:00 45.6 45.60 0 9.0 07/06/85 24:00 48.0 48.00 0 8.0 DAILY AVG VALUES 46.5 46.50 0 6.9 07/07/85 06:00 47.6 47.60 0 6.0 07/07/85 12:00 48.4 48.40 0 6.0 07/07/85 18:00 51.6 51.60 0 6.0 07/07/85 24:00 50.8 50.80 0 6.0 DAILY AVG VALUES 49.6 49.60 0 6.0 07/08/85 06:00 49.2 49.20 0 5.0 07/08/85 12:00 47.6 47.60 0 5.0 07/08/85 18:00 46.8 46.80 0 6.0 07/08/85 24:00 45.6 45.60 0 6.0 DAILY AVG VALUES 47.3 47.30 0 5.5 07/09/85 06:00 44.8 44.80 0 5.0 07/09/85 12:00 43.2 43.20 0 5.5 07/09/85 18:00 43.2 43.20 0 8.5 07/09/85 24:00 44.8 44.80 0 8.0 DAILY AVG VALUES 44.0 44.00 0 6.8 07/10/85 06:00 44.4 44.40 0 5.5 07/10/85 12:00 43.2 43.20 0 5.5 07/10/85 18:00 43.2 43.20 0 9.0 07/10/85 24:00 44.0 44.00 0 7.5 DAILY AVG VALUES 43.7 43.70 0 6.9 07/11/85 06:00 44.0 44.00 0 5.5 07/11/85 12:00 43.2 43.20 0 6.0 07/11/85 18:00 42.8 42.80 0 8.0 07 I 11/85 24:00 44.0 44.00 0 7.0 DAILY AVG VALUES 43.5 43.50 0 6.6 07/12/85 06:00 43.2 43.20 0 6.0 07/12/85 12:00 42.0 42.00 0 6.5 07/12/85 18:00 42.4 42.40 0 9.0 07/12/85 24:00 42.4 42.40 0 8.0 DAILY AVG VALUES 42.5 42.50 0 7.4 07/13/85 06:00 42.8 42.80 0 6.5 07/13/85 12:00 41.2 41.20 0 6.5 07/13/85 18:00 41.6 41.60 0 9.0 07/13/85 24:00 42.4 42.40 0 8.5 DAILY AVG VALUES 42.0 42.00 0 7.6 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 10 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 07/14/85 06:00 42.8 42.80 0 6.0 07/14/85 12:00 41.6 41.60 0 6.5 07/14/85 18:00 41.6 41.60 0 9.0 07/14/85 24:00 43.6 43.60 0 8.5 DAILY AVG VALUES 42.4 42.40 0 7.5 07/15/85 06:00 42.8 42.80 0 5.5 07/15/85 12:00 41.2 41.20 0 6.0 07/15/85 18:00 40.8 40.80 0 9.0 07/15/85 24:00 43.2 43.20 0 8.5 DAILY AVG VALUES 42.0 42.00 0 7.3 07/16/85 06:00 42.8 42.80 0 6.0 07/16/85 12:00 41.6 41.60 0 6.0 07/16/85 18:00 42.0 42.00 0 8.5 07/16/85 24:00 43.6 43.60 0 7.5 DAILY AVG VALUES 42.5 42.50 0 7.0 07/17/85 06:00 44.4 44.40 0 6.5 07/17/85 12:00 44.0 44.00 0 6.5 07/17/85 18:00 43.2 43.20 0 9.5 07/17/85 24:00 45.6 45.60 0 8.5 DAILY AVG VALUES 44.3 44.30 0 7.8 07/18/85 06:00 44.0 44.00 0 7.0 07/18/85 12:00 43.6 43.60 0 7.5 07/18/85 18:00 43.6 43.60 0 8.5 07/18/85 24:00 44.8 44.80 0 8.5 DAILY AVG VALUES 44.0 44.00 0 7.9 07/19/85 06:00 43.6 43.60 0 7.0 07/19/85 12:00 44.8 44.80 0 7.5 07/19/85 18:00 47.2 47.20 0 7.5 07/19/85 24:00 48.8 48.80 0 7.0 DAILY AVG VALUES 46.1 46.10 0 7.3 07/20/85 06:00 50.8 50.80 0 6.0 07/20/85 12:00 49.6 49.60 0 6.0 07/20/85 18:00 48.0 48.00 0 8.0 07/20/85 24:00 47.6 47.60 0 7.5 DAILY AVG VALUES 49.0 49.00 0 6.9 07/21/85 06:00 47.6 47.60 0 5.5 07/21/85 12:00 45.6 45.60 0 5.5 07/21/85 18:00 44.0 44.00 0 7.0 07/21/85 24:00 44.8 44.80 0 7.0 DAILY AVG VALUES 45.5 45.50 0 6.3 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 11 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 07/22/85 06:00 44.4 44.40 0 5.5 07/22/85 12:00 44.0 44.00 0 6.0 07/22/85 18:00 43.2 43.20 0 7.5 07/22/85 24:00 44.0 44.00 0 7.0 DAILY AVG VALUES 43.9 43.90 0 6.5 07/23/85 06:00 43.6 43.60 0 5.5 07/23/85 12:00 42.8 42.80 0 5.5 07/23/85 18:00 41.6 41.60 0 7.5 07/23/85 24:00 41.2 41.20 0 7.0 DAILY AVG VALUES 42.3 42.30 0 6.4 07/24/85 06:00 40.0 40.00 0 6.0 07/24/85 12:00 38.8 38.80 0 6.0 07/24/85 18:00 38.0 38.00 0 9.5 07/24/85 24:00 38.8 38.80 0 9.0 DAILY AVG VALUES 38.9 38.90 0 7.6 07/25/85 06:00 38.4 38.40 0 6.0 07/25/85 12:00 37.2 37.20 0 6.0 07/25/85 18:00 36.0 36.00 0 10.5 07/25/85 24:00 38.0 38.00 0 9.5 DAILY AVG VALUES 37.4 37.40 0 8.0 07/26/85 06:00 38.0 38.00 0 7.5 07/26/85 12:00 37.2 37.20 0 7.5 07/26/85 18:00 36.4 36.40 0 9.5 07/26/85 24:00 36.8 36.80 0 8.5 DAILY AVG VALUES 37.1 37.10 0 8.3 07/27/85 06:00 36.8 36.80 0 7.0 07/27/85 12:00 35.6 35.60 0 6.5 07/27/85 18:00 34.4 34.40 0 8.5 07/27/85 24:00 35.6 35.60 0 8.5 DAILY AVG VALUES 35.6 35.60 0 7.6 07/28/85 06:00 35.2 35.20 0 6.5 07/28/85 12:00 33.6 33.60 0 6.5 07/28/85 18:00 32.8 32.80 8.5 07/28/85 24:00 33.6 33.60 0 8.0 DAILY AVG VALUES 33.8 33.80 0 7.4 07/29/85 06:00 33.6 33.60 0 6.5 07/29/85 12:00 33.2 33.20 0 6.5 07/29/85 18:00 32.0 32.00 0 8.5 07/29/85 24:00 33.6 33.60 0 9.0 DAILY AVG VALUES 33.1 33.10 0 7.6 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 12 PREPARED BY DRYDEN & LARUE DATA FILE NFBRC.POD 23-AUG-85 NORTH FORK OF BRADLEY RIVER START TIME 05/02/85 24:00 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 07/30/85 06:00 34.0 34.00 0 7.0 07/30/85 12:00 33.6 33.60 0 6.5 07/30/85 18:00 32.4 32.40 0 9.0 07/30/85 24:00 32.0 32.00 0 8.5 DAILY AVG VALUES 33.0 33.00 0 7.8 07/31/85 06:00 32.8 32.80 0 6.0 07/31/85 12:00 31.6 31.60 0 5.5 07/31/85 18:00 30.8 30.80 0 9.5 07/31/85 24:00 31.2 31.20 0 9.5 DAILY AVG VALUES 31.6 31.60 0 7.6 08/01/85 06:00 31.6 31.60 0 6.0 08/01/85 12:00 30.4 30.40 0 6.0 08/01/85 18:00 29.6 29.60 0 8.5 08/01/85 24:00 30.0 30.00 0 8.5 DAILY AVG VALUES 30.4 30.40 0 7.3 08/02/85 06:00 30.4 30.40 0 7.0 08/02/85 12:00 30.4 30.40 0 7.0 08/02/85 18:00 29.6 29.60 0 9.0 08/02/85 24:00 30.8 30.80 9.5 DAILY AVG VALUES 30.3 30.30 0 8.1 08/03/85 06:00 31.6 31.60 0 7.0 DAILY AVG VALUES 31.6 31.60 0 7.0 D-BL/107 D-BL/107 Bradley Lake Hydroelectric Project Environmental Monitoring Program Water Quality Data Report Submitted to Stone and Webster Engineering Corporation 800 A Street Anchorage, Alaska Attention: Mr. T. Critikos by NORTHERN TECHNICAL SERVICES, INC. 750 W. 2nd Avenue Anchorage, Alaska 99501 The Bradley River is currently being monitored at three locations for water temperature. As part of the 1985 environmental monitoring pro- gram, instruments maintained at these locations are serviced; data storage chips retrieved; data recovered from chips (by Dryden and Larue); and the summarized data is transmitted in report form to Stone and Webster Engineering Corporation. This is the second in a series of reports covering the water quality task and includes the data obtained from the servicing of water quality instruments on August 31, 1985. The data is presented in three attachments: Attachment I -Riffle Reach Attachment II -Tree Bar Reach Attachment III -North Fork Bradley River The data covers the period from August 1-31, 1985. A summary of the servicing record is presented below: 1. Riffle Reach. during mid-August This unit was visited by the fisheries field crew at which time it was determined that the unit malfunction reported at the last servicing was in one of the probes. The probe was later replaced and the unit appeared to function properly for a short time. However, the Datapod itself developed a fault in which Channel 2 consistently read "-05. OC", regardless of which probe was used. During the 31 August field service visit, the entire unit (including the probes) was recovered and brought to Anchorage for repair. Dryden and Larue repaired the unit and it is ready for rede- ployment at the next servicing date. 2. Tree Bar Reach, serviced 31 Aug 85/1015 hrs. The unit appeared to be functioning properly; "short dump" performed. Data storage module (DSM) was replaced and initialized. The batteries were not replaced since their expected life is approximately one ye<H. The two temperature probes were traced to a stake in the streambed. The stake D-BL/107 D-BL/107 ATTACHMENT I Riffle Reach Water Quality Data August 1-31, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 PREPARED BY DRYDEN & LARUE DATA FILE PRTTD.POD 27-SEP-85 RIFFLE REACH START TIME 08/01/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 08/01/85 24:00 -5.0 -5.0 -5.0 7.8 7.7 7.9 08/02/85 06:00 -5.0 -5.0 -5.0 7.9 7.9 7.9 08/02/85 12:00 -5.0 -5.o -5.0 7.8 7.8 7.9 08/02/85 18:00 -4.9 -5.0 -4.8 7.9 7.8 8.0 08/02/85 24:00 -4.9 -5.0 -4.8 8.1 7.9 8.3 08/03/85 06:00 -0.1 -5.0 3.4 8.2 8.1 8.3 08/03/85 12:00 -3.2 -5.0 3.4 8.0 7.9 8.1 08/03/85 18:00 0.5 -5.0 3.4 8.1 7.9 8.2 08/03/85 24:00 0.9 -4.8 4.2 8.3 8.1 8.4 08/04/85 06:00 -2.0 -5.0 2.0 8.3 8.1 8.3 08/04/85 12:00 -5.0 -5.0 -5.0 8.1 8.0 8.2 08/04/85 18:00 0.3 -5.0 4.5 8.2 8.0 8.3 08/04/85 24:00 -3.4 -5.0 4.5 8.3 8.2 8.4 08/05/85 06:00 -4.5 -5.0. -2.9 8.3 8.2 8.4 08/05/85 12:00 0.5 -5.0 1.8 8.2 8.1 8.3 08/05/85 18:00 -0.8 -5.0 2.2 8.2 8.0 8.3 08/05/85 24:00 -4.5 -5.0 3.5 8.3 8.2 8.4 08/06/85 06:00 -5.0 -5.0 -4.8 8.1 8.0 8.2 08/06/85 12:00 0.2 -5.0 3.6 8.0 7.9 8.1 08/06/85 18:00 -1.6 -5.0 1.3 8.0 7.9 8.1 08/06/85 24:00 0.7 -5.0 2.7 8.2 8.1 8.3 08/07/85 06:00 0.6 -2.8 2.6 8.2 8.2 8.3 08/07/85 12:00 -2.6 -5.0 1.2 8.1 8.0 8.2 08/07/85 18:00 1.6 -5.0 3.4 8.1 8.0 8.2 08/07/85 24:00 -3.2 -5.0 2.2 8.2 8.1 8.3 08/08/85 06:00 -4.3 -5.0 -0.8 8.1 8.0 8.2 08/08/85 12:00 -1.3 -5.0 2.8 7.9 7.8 8.0 08/08/85 18:00 0.7 -5.0 4.1 7.8 7.8 7.9 08/08/85 24:00 -2.1 -5.o 3.4 7.8 7.7 7.9 08/09/85 06:00 -4.1 -5.o 6.5 7.6 7.4 7.8 08/09/85 12:00 -5.0 -5.0 -5.0 7.4 7.3 7.4 08/09/85 18:00 -3.8 -5.0 -0.3 7.3 7.3 7.4 08/09/85 24:00 -2.4 -5.0 1.1 7.4 7.3 7.4 08/10/85 06:00 -3.3 -5.0 0.5 7.4 7.3 7.4 08/10/85 12:00 -3.5 -5.0 2.4 7.3 7.2 7.4 08/10/85 18:00 -0.7 -5.0 1.9 7.3 7.2 7.4 08/10/85 24:00 -3.7 -5.0 1.3 7.4 7.3 7.5 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 PREPARED BY DRYDEN & LARUE DATA FILE RRTTD.POD 27-SEP-85 RIFFLE REACH START TIME 08/01/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX -- 08/11/85 06:00 -3.6 -5.0 2.0 7.4 7.3 7.5 08/11/85 12:00 -4.6 -5.0 -0.9 7.2 7.1 7.3 08/11/85 18:00 -4.6 -5.0 2.3 7.2 7.2 7.3 08/11/85 24:00 -1.2 -5.0 2.9 7.3 7.2 7.3 08/12/85 06:00 -1.5 -5.0 1.2 7.3 7.2 7.3 08/12/85 12:00 -5.0 -5.0 -5.0 7.3 7.2 7.3 08/12/85 18:00 -2.6 -5.0 7.4 7.2 -4.8 7.4 08/12/85 24:00 -5.0 -5.0 -5.0 7.4 7.4 7.4 08/13/85 06:00 -4.6 -5.0 0.5 7.3 7.2 7.4 08/13/85 12:00 -0.3 -5.0 2.6 7.2 7.2 7.3 08/13/85 18:00 -0.3 -5.0 3.4 7.2 7.1 7.2 08/13/85 24:00 -1.9 -5.0 2.9 7.3 7.2 7.3 08/14/85 06:00 -4.3 -5.0 1.2 7.3 7.2 7.3 08/14/85 12:00 -4.3 -5.0 -0.6 7.2 7.2 7.3 08/14/85 18:00 -3.3 -5.0 4.9 7.3 7.2 7.4 08/14/85 24:00 -4.3 -5.0 -0.1 7.4 7.3 7.4 08/15/85 06:00 -4.8 -5.0 0.4 7.3 7.2 7.4 08/15/85 12:00 -4.6 -5.0 -2.3 7.2 7.2 7.3 08/15/85 18:00 -2.2 -5.0 1.0 7.1 7.1 7.2 08/15/85 24:00 -3.2 -5.0 -0.8 7.2 7.1 7.3 08/16/85 06:00 -4.0 -5.0 -0.6 7. 1 7.1 7.2 08/16/85 12:00 -4.0 -5.0 1.7 7.0 7.0 7.1 08/16/85 18:00 -2.4 -5.0 1.7 7.0 6.9 7.1 08/16/85 24:00 -3.0 -5.0 2.4 7.1 7.0 7.2 08/17/85 06:00 -2.1 -5.0 1.6 7.1 7.0 7.2 08/17/85 12:00 -3.8 -5.0 2.2 6.9 6.9 7.0 08/17/85 18:00 -4.9 -5.0 -4.8 6.9 6.8 7.0 08/17/85 24:00 -3.5 -5.0 2.8 7.1 7.0 7.2 08/18/85 06:00 -1.6 -5.0 2.9 7.1 7.0 7.2 08/18/85 12:00 -1.8 -5.0 1.5 6.9 6.8 7.1 08/18/85 18:00 -4.1 -5.0 8.0 7.0 6.8 7.1 08/18/85 24:00 -3.1 -5.0 1.1 7.3 7.0 7.4 08/19/85 06:00 -3.0 -5.0 2.1 7.3 7.3 7.3 08/19/85 12:00 -5.0 -5.0 -5.0 7.2 7.2 7.3 08/19/85 18:00 -1.6 -5.0 1.3 7.3 7.2 7.3 08/19/85 24:00 -3.7 -5.0 2.3 7.3 7.2 7.3 08/20/85 06:00 -2.4 -5.0 1.8 7.2 7.2 7.3 08/20/85 12:00 -1.3 -5.0 2.9 7.3 7.2 7.3 08/20/85 18:00 -4.9 -5.0 -4.8 7.3 7.2 7.4 08/20/85 24:00 -5.0 -5.0 -4.8 7.4 7.4 7.5 T'\. TIT f 1 fY'i NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 PREPARED BY DRYDEN & LARUE DATA FILE RRTTD.POD 27-SEP-85 RIFFLE REACH START TIHE 08/01/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 08/21/85 06:00 -5.0 -5.0 -5.0 7.4 7.3 7.5 08/21/85 12:00 -5.0 -5.0 -5.0 7.3 7.3 7.3 08/21/85 18:00 -5.0 -5.0 -5.0 7.2 7.1 7.3 08/21/85 24:00 -4.2 -5.0 1.2 7.2 7.1 7.3 08/22/85 06:00 -3.1 -5.0 1.7 7.1 7.1 7.2 08/22/85 12:00 -1.2 -5.0 3.4 7. 1 7.0 7. 1 08/22/85 18:00 -5.0 -5.0 -5.0 7.0 7.0 7. 1 08/22/85 24:00 -4.9 -5.0 -4.8 7.2 7.0 7.3 08/23/85 06:00 -4.9 -5.0 -4.8 6.8 6.7 7.0 08/23/85 12:00 -5.0 -5.0 -4.8 6.8 6.6 7.2 08/23/85 18:00 -4.9 -5.0 -4.8 7.9 7.2 8.1 08/23/85 24:00 -4.9 -5.0 -4.8 7~7 7.2 8. 1 08/24/85 06:00 -5.0 -5.0 -5.0 7.0 6.9 7.2 08/24/85 12:00 -5.0 -5.0 -5.0 7.1 6.9 7.6 08/24/85 18:00 -5.0 -5.0 -5.0 8. 1 7.5 8.4 08/24/85 24:00 -5.0 -5.0 -5.0 7.9 7.5 8.3 08/25/85 06:00 -5.0 -5.0 -4.9 7.4 7.3 7.6 08/25/85 12:00 -5.0 -5.0 -4.9 7.4 7.3 7.8 08/25/85 18:00 -4.9 -5.0 -4.8 8.2 7.8 8.4 08/25/85 24:00 -4.8 -5.0 -4.8 8. 1 7.7 8.4 08/26/85 06:00 -4.9 -5.0 -4.8 7.5 7.4 7.7 08/26/85 12:00 -4.8 -5.0 -4.8 7.5 7.4 7.7 08/26/85 18:00 -4.8 -4.8 -4.8 8.5 7.7 8.8 08/26/85 24:00 -4.8 -4.8 -4.8 8.2 7.6 8.7 08/27/85 06:00 -4.8 -5.0 -4.8 7.2 6.8 7.6 08/27/85 12:00 -4.8 -5.0 -4.8 6.9 6.8 7.3 08/27/85 18:00 -4.8 -5.0 -4.8 8.3 7.3 8.8 08/27/85 24:00 -4.8 -4.8 -4.8 8.2 7.6 8.7 08/28/85 06:00 -4.8 -5.0 -4.8 7.2 6.9 7.6 08/28/85 12:00 -4.9 -5.0 -4.8 7.0 6.9 7.5 08/28/85 18:00 0.8 -5.0 20.5 6.9 -5.0 16.9 08/28/85 24:00 -3.7 -5.0 20.5 8.2 8.0 8.4 08/29/85 06:00 -5.0 -5.0 -5.0 7.9 7.8 8.1 08/29/85 12:00 -5.0 -5.0 -5.0 7.9 7.8 8. 1 08/29/85 18:00 -5.0 -5.0 -5.0 8.8 8.2 9.1 08/29/85 24:00 -5.0 -5.0 -5.0 8.6 8.2 9.0 08/30/85 06:00 -5.0 -5.0 -5.0 7.8 7.5 8.2 08/30/85 12:00 -5.0 -5.0 -5.0 7.5 7.3 8.0 08/30/85 18:00 4.2 -5.0 20.5 8.8 8.0 9.3 08/30/85 24:00 1.0 -5.0 20.5 8.7 8.2 9.3 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 PREPARED BY DRYDEN & LARUF. DATA FILE RRTTD.POD 27-SEP-85 RIFFLE REACH START TIME 08/01/85 24:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX -- 08/31/85 06:00 -5.0 -5.0 -5.0 8.0 7.9 8.2 08/31/85 12:00 1.0 -5.0 13.6 9.7 8.0 13.8 08/31/85 18:00 14.5 13.8 15.1 14.6 14.0 15.2 08/31/85 24:00 13.3 12.4 13.9 13.4 12.6 14.1 D-BL/107 D-BL/107 Attachment II Tree Bar Reach Water Quality Data August 1-31. 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTD.POD 27-SEP-85 TREE BAR REACH START TIME 08/01/85 18:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 08/01/85 18:00 9.7 9.7 9.8 8.9 8.9 9.0 08/01/85 24:00 9.5 9.0 9.8 8.9 8.8 9.0 08/02/85 06:00 8.9 8.8 9.1 8.9 8.9 9.0 08/02/85 12:00 8.7 8.6 9 .1 9.1 9.0 9.2 08/02/85 18:00 9.9 9.1 10.4 9.1 9.1 9.2 08/02/85 24:00 10.1 9.4 10.4 9.2 9.1 9.3 08/03/85 06:00 8.8 8.6 9.4 9.3 9.2 9.5 08/03/85 12:00 8.7 8.5 9.2 9.5 9.4 9.5 08/03/85 18:00 10.0 9.2 10.4 9.4 9.3 9.4 08/03/85 24:00 9.8 9.3 10.3 9.3 9.3 9.4 08/04/85 06:00 8.9 8.7 9.3 9.4 9.3 9.5 08/04/85 12:00 9.0 8.7 9.3 9.5 9.5 9.6 08/04/85 18:00 9.7 9.2 10.0 9.4 9.3 9.5 08/04/85 24:00 9.6 9.2 10.0 9.4 9.3 9.4 08/05/85 06:00 8.9 8.6 9.2 9.4 9.3 9.5 08/05/85 12:00 8.7 8.5 9.3 9.5 9.3 9.5 08/05/85 18:00 10.1 9.3 10.3 9.4 9.3 9.5 08/05/85 24:00 8.8 8.0 10.0 9.3 9.3 9.4 08/06/85 06:00 8.3 7.9 8.7 9.3 9.3 9.4 08/06/85 12:00 8.6 8.4 8.9 9.2 9.1 9.4 08/06/85 18:00 9.3 8.8 9.6 9.0 8.9 9.2 08/06/85 24:00 9.4 9.0 9.6 8.9 8.9 9.0 08/07/85 06:00 8.8 8.6 9.0 9.0 8.9 9.1 08/07/85 12:00 8.6 8.5 8.7 9.1 9.1 9.2 08/07/85 18:00 9.3 8.6 9.6 9.1 9.0 9.2 08/07/85 24:00 8.8 8.3 9.4 9.1 9.0 9.1 08/08/85 06:00 8.2 8.0 8.4 9.1 9.0 9.1 08/08/85 12:00 7.9 7.8 8.2 9.0 8.9 9.1 08/08/85 18:00 8.3 8.1 8.6 8.7 8.5 8.9 08/08/85 24:00 7.6 7.0 8.3 8.5 8.4 8.6 08/09/85 06:00 6.9 6.8 7.2 8.4 8.3 8.5 08/09/85 12:00 7.2 7.1 7.4 8.1 8.0 8.3 08/09/85 18:00 7.6 7.4 7.8 7.9 7.8 8.0 08/09/85 24:00 7.7 7.5 7.8 7.7 7.7 7.8 08/10/85 06:00 7.5 7.4 7.6 7.7 7.7 7.8 08/10/85 12:00 7.5 7.4 7.6 7.8 7.7 7.8 08/10/85 18:00 8.1 7.6 8.3 7.8 7.7 7.8 08/10/85 24:00 7.8 7.3 8.2 7.8 7.7 7.9 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTD.POD 27-SEP-85 TREE BAR REACH START TIME 08/01/85 18:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX -- 08/11/85 06:00 7.2 7.1 7.4 7.9 7.8 7.9 08/11/85 12:00 7.3 7.0 7.7 7.9 7.9 8.0 08/11/85 18:00 7.8 7.7 7.9 7.8 7.7 7.9 08/11/85 24:00 7.8 7.7 7.9 7.8 7.7 7.8 08/12/85 06:00 7.8 7.7 7.8 7.8 7.7 7.8 08/12/85 12:00 7.8 7.7 7.9 7.9 7.8 7.9 08/12/85 18:00 8.0 7.9 8.0 7.9 7.8 8.0 08/12/85 24:00 7.8 7.5 8.0 7.9 7.9 8.0 08/13/85 06:00 7.2 7. 1 7.5 8.0 8.0 8.0 08/13/85 12:00 7.3 7.1 7.5 7.9 7.8 8.0 08/13/85 .18:00 7.8 7.4 8.1 7.8 7.7 7.8 08/13/85 24:00 7.8 7.4 8.0 7.7 7.7 7.8 08/14/85 06:00 7.5 7.3 7.7 7.8 7.8 7.9 08/14/85 12:00 7.8 7.7 8.2 7.8 7.8 7.9 08/14/85 18:00 8.1 7.9 8.3 7.9 7.8 7.9 08/14/85 24:00 7.7 7.4 7.9 7.9 7.9 8.0 08/15/85 06:00 7.3 7.1 7.5 8.0 7.9 8.0 08/15/85 12:00 7.1 7.1 7.2 7.9 7.8 8.0 08/15/85 18:00 7.4 7.2 7.6 7.7 7.6 7.8 08/15/85 24:00 7.4 7.0 7.6 7.6 7.6 7.7 08/16/85 06:00 7.0 6.9 7.1 7.6 7.6 7.7 08/16/85 12:00 7.0 6.9 7.3 7.6 7.5 7.6 08/16/85 18:00 7.7 7.3 7.9 7.4 7.4 7.5 08/16/85 24:00 7.4 6.9 7.8 7.5 7.4 7.5 08/17/85 06:00 6.7 6.7 6.9 7.6 7.5 7.6 08/17/85 12:00 6.8 6.6 7.2 7.5 7.4 7.6 08/17/85 18:00 7.8 7.2 8.2 7.3 7.3 7.4 08/17/85 24:00 7.6 7.1 8.0 7.4 7.3 7.5 08/18/85 06:00 6.8 6.7 7.1 7.6 7.5 7.7 08/18/85 12:00 6.8 6.6 7.5 7.6 7.5 7.6 08/18/85 18:00 8.4 7.5 8.8 7.5 7.4 7.5 08/18/85 24:00 8.3 7.9 8.7 7.5 7.4 7.6 08/19/85 06:00 7.7 7.6 7.9 7.8 7.6 8.0 08/19/85 12:00 7.7 7.6 7.8 8.0 8.0 8.0 08/19/85 18:00 7.8 7.7 7.9 8.0 8.0 8. 1 08/19/85 24:00 7.7 7.6 7.7 8.0 8.0 8. 1 08/20/85 06:00 7.6 7.6 7.7 8.0 8.0 8.0 08/20/85 12:00 7.7 7.5 8.0 7.9 7.9 8.0 08/20/85 18:00 8.4 8.0 8.5 7.9 7.9 8.0 08/20/85 24:00 8.0 7.7 8.3 8.0 7.9 8. 1 1'"1-lH /1117 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTD.POD 27-SEP-85 TREE BAR REACH START TIME 08/01/85 18:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 08/21/85 06:00 7.6 7.5 7.7 8. 1 8.0 8. 1 08/21/85 12:00 7.4 7.3 7.5 8. 1 8.0 8.1 08/21/85 18:00 7.4 7.3 7.6 7.9 7.8 8.0 08/21/85 24:00 7.3 7.0 7.6 7.8 7.7 7.9 08/22/85 06:00 7.0 6.9 7.0 7.7 7.7 7.8 08/22/85 12:00 7.0 6.9 7.2 7.6 7.5 7.7 08/22/85 18:00 7.5 7.2 7.7 7.5 7.4 7.5 08/22/85 24:00 7.3 7.0 7.6 7.5 7.4 7.6 08/23/85 06:00 6.8 6.6 7.0 7.6 7.5 7.6 08/23/85 12:00 6.7 6.6 7.2 7.5 7.3 7.6 08/23/85 18:00 7.8 7.2 8.0 7.3 7.2 7.3 08/23/85 24:00 7.6 7.2 8.0 7.4 7.3 7.5 08/24/85 06:00 7.0 6.9 7.2 7.5 7.5 7.6 08/24/85 12:00 7.1 6.9 7.6 7.6 7.5 7.6 08/24/85 18:00 8.0 7.5 8.3 7.5 7.5 7.6 08/24/85 24:00 7.8 7.5 8.2 7.7 7.5 7.8 08/25/85 06:00 7.4 7.3 7.5 7.8 7.7 7.8 08/25/85 12:00 7.4 7.3 7.8 7.8 7.7 7.8 08/25/85 18:00 8.2 7.7 8.3 7.8 7.7 7.9 08/25/85 24:00 8.1 7.7 8.3 8.0 7.9 8.0 08/26/85 06:00 7.5 7.5 7.7 8.2 8.0 8.5 08/26/85 12:00 7.5 7.4 7.7 8.1 8.1 8.2 08/26/85 18:00 8.4 7.6 8.8 8.2 8. 1 8.3 08/26/85 24:00 8.1 7.6 8.6 8.3 8.3 8.4 08/27/85 06:00 7.1 6.8 7.6 8.1 7.9 8.3 08/27/85 12:00 6.9 6.8 7.3 7.8 7.7 7.9 08/27/85 18:00 8.3 7.3 8.7 8.0 7.8 8.1 08/27/85 24:00 8. 1 7.5 8.6 8.1 8.0 8.2 08/28/85 06:00 7. 1 6.9 7.5 8.0 7.9 8.1 08/28/85 12:00 7.1 6.9 7.5 7.9 7.8 7.9 08/28/85 18:00 8.2 7.5 8.5 8.0 7.8 8.1 08/28/85 24:00 8.3 8.2 8.5 8.0 7.9 8.1 08/29/85 06:00 8.0 7.9 8.2 8. 1 8.0 8.1 08/29/85 12:00 8.0 7.9 8.3 8.2 8.1 8.3 08/29/85 18:00 8.9 8.3 9.2 8.3 8.3 8.4 08/29/85 24:00 8.7 8.2 9. 1 8.5 8.4 8.5 08/30/85 06:00 7.9 7.6 8.3 8.5 8.5 8.5 08/30/85 12:00 7.7 7.5 8.2 8.5 8.4 8.5 08/30/85 18:00 8.9 8.2 9.4 8.6 8.5 8.7 08/30/85 24:00 8.8 8.4 9.3 8.6 8.5 8.6 1"\_lH {1()7 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 PREPARED BY DRYDEN & LARUE DATA FILE TBRTTD.POD 27-SEP-85 TREE BAR REACH START TIME 08/01/85 18:00 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 08/31/85 06:00 8.2 8. 1 8.4 8.6 8.5 8.6 D-BL/107 D-BL/107 Attachment III North Fork Bradley River Water Quality Data August 3-31, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 PREPARED BY DRYDEN & LARUE DATA FILE NFBRDD. POD 27-SEP-85 NORTH FORK OF BRADLEY RIVER START TIME 08/03/85 15:30 DISCHG=Gl*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 08/03/85 15:30 30.8 30.80 0 8.0 08/03/85 21:30 30.4 30.40 0 10.0 DAILY AVG VALUES 30.6 30.60 0 9.0 08/04/85 03:30 32.0 32.00 0 8.0 08/04/85 09:30 32.0 32.00 0 7.0 08/04/85 15:30 32.0 32.00 0 7.5 08/04/85 21:30 32.0 32.00 0 9.0 DAILY AVG VALUES 32.0 32.00 0 7.9 08/05/85 03:30 32.8 32.80 0 7.5 08/05/85 09:30 31.6 31.60 0 5.5 08/05/85 15:30 30.8 30.80 0 7.5 08/05/85 21:30 30.8 30.80 0 10.5 DAILY AVG VALUES 31.5 31.50 0 7.8 08/06/85 03:30 31.6 31.60 0 8.5 08/06/85 09:30 33.2 33.20 0 7.5 08/06/85 15:30 33.2 33 .• 20 0 8.0 08/06/85 21:30 33.2 33.20 0 9.0 DAILY AVG VALUES 32.8 32.80 0 8.3 08/07/85 03:30 32.4 32.40 0 8.0 08/07/85 09:30 32.0 32.00 0 7.0 08/07/85 15:30 34.0 34.00 0 8.0 08/07/85 21:30 38.0 38.00 0 9.0 DAILY AVG VALUES 34.1 34.10 0 8.0 08/08/85 03:30 38.4 38.40 0 7.0 08/08/85 09:30 37.2 37.20 0 6.0 08/08/85 15:30 34.4 34.40 0 6.5 08/08/85 21:30 32.4 32.40 0 8.0 DAILY AVG VALUES 35.6 35.60 0 6.9 08/09/85 03:30 31.6 31.60 0 6.5 08/09/85 09:30 30.0 30.00 0 6.0 08/09/85 15:30 29.2 29.20 0 7.0 08/09/85 21:30 30.4 30.40 0 7.5 DAILY AVG VALUES 30.3 30.30 0 6.8 08/10/85 03:30 30.8 30.80 0 7 .o 08/10/85 09:30 30.4 30.40 0 6.5 08/10/85 15:30 30.0 30.00 0 7 .o 08/10/85 21:30 28.8 28.80 0 9.0 DAILY AVG VALUES 30.0 30.00 0 7.4 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 PREPARED BY DRYDEN & LARUE DATA FILE NFBRDD. POD 27-SEP-85 NORTH FORK OF BRADLEY RIVER START TIME 08/03/85 15:30 DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 08/11/85 03:30 29.2 29.20 0 7.5 08/11/85 09:30 28.8 28.80 0 6.5 08/11/85 15:30 27.6 27.60 0 7.5 08/11/85 21:30 28.8 28.80 0 8.5 DAILY AVG VALUES 28.6 28.60 0 7.5 08/12/85 03:30 31.6 31.60 0 8.5 08/12/85 09:30 39.6 39.60 0 8.5 08/12/85 15:30 42.8 42.80 0 8.5 08/12/85 21:30 45.6 45.60 0 8.5 DAILY AVG VALUES 39.9 39.90 0 8.5 08/13/85 03:30 48.0 48.00 0 7.5 08/13/85 09:30 47.2 47.20 0 7.0 08/13/85 15:30 47.2 47.20 0 7.5 08/13/85 21:30 47.2 47.20 0 8.5 DAILY AVG VALUES 47.4 47.40 0 7.6 08/14/85 03:30 46.0 46.00 0 7.0 08/14/85 09:30 45.2 45.20 0 7.5 08/14/85 15:30 44.8 44.80 0 8.5 08/14/85 21:30 47.6 47.60 0 8.5 DAILY AVG VALUES 45.9 45.90 0 7.9 08/15/85 03:30 47.2 47.20 0 7.0 08/15/85 09:30 46.4 46.40 0 6.5 08/15/85 15:30 44.4 44.40 0 6.5 08/15/85 21:30 42.4 42.40 0 7.0 DAILY AVG VALUES 45.1 45.10 0 6.8 08/16/85 03:30 41.2 41.20 0 6.5 08/16/85 09:30 40.4 40.40 0 6.0 08/16/85 15:30 39.2 39.20 0 6.5 08/16/85 21:30 38.4 38.40 0 8.0 DAILY AVG VALUES 39.8 39.80 0 6.8 08/17/85 03:30 38.4 38.40 0 6.0 08/17/85 09:30 36.0 36.00 0 5.0 08/17/85 15:30 34.8 34.80 0 6.5 08/17/85 21:30 34.0 34.00 0 9.5 DAILY AVG VALUES 35.8 35.80 0 6.8 08/18/85 03:30 34.8 34.80 0 7.0 08/18/85 09:30 32.8 32.80 0 5.0 08/18/85 15:30 30.8 30.80 0 7.5 08/18/85 21:30 30.8 30.80 0 10.0 DAILY AVG VALUES 32.3 32.30 0 7.4 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 PREPARED BY DRYDEN & LARUE DATA FILE NFBRDD. POD 27-SEP-85 NORTH FORK OF BRADLEY RIVER START TIME 08/03/85 15:30 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 08/19/85 03:30 31.2 31.20 0 7.5 08/19/85 09:30 30.4 30.40 0 7.0 08/19/85 15:30 29.2 29.20 0 7.0 08/19/85 21:30 32.4 32.40 0 7.5 DAILY AVG VALUES 30.8 30.80 0 7.3 08/20/85 03:30 31.2 31.20 0 7.0 08/20/85 09:30 32.0 32.00 0 7.0 08/20/85 15:30 31.6 31.60 0 8.0 08/20/85 21:30 32.4 32.40 0 8.5 DAILY AVG VALUES 31.8 31.80 0 7.6 08/21/85 03:30 36.4 36.40 0 7.0 08/21/85 09:30 35.6 35.60 0 6.5 08/21/85 15:30 42.4 42.40 0 6.5 08/21/85 21:30 44.4 44.40 0 7.0 DAILY AVG VALUES 39.7 39.70 0 6.8 08/22/85 03:30 44.0 44.00 0 6.5 08/22/85 09:30 40.8 40.80 0 6.0 08/22/85 15:30 40.4 40.40 0 6.5 08/22/85 21:30 41.2 41.20 0 7.5 DAILY AVG VALUES 41.6 41.60 0 6.6 08/23/85 03:30 38.8 38.80 0 6.0 08/23/85 09:30 37.2 37.20 0 5.0 08/23/85 15:30 35.2 35.20 0 6.5 08/23/85 21:30 34.0 34.00 0 9.0 DAILY AVG VALUES 36.3 36.30 0 6.6 08/24/85 03:30 34.0 34.00 0 7.0 08/24/85 09:30 32.8 32.80 0 6.0 08/24/85 15:30 31.6 31.60 0 7.5 08/24/85 21:30 31.2 31.20 0 8.5 DAILY AVG VALUES 32.4 32.40 0 7.3 08/25/85 03:30 31.2 31.20 0 7.0 08/25/85 09:30 29.6 29.60 0 6.0 08/25/85 15:30 28.8 28.80 0 7.0 08/25/85 21:30 28.8 28.80 0 8.5 DAILY AVG VALUES 29.6 29.60 0 7.1 08/26/85 03:30 28.8 28.80 0 7.5 08/26/85 09:30 28.0 28.00 0 6.5 08/26/85 15:30 27.2 27.20 0 7.5 08/26/85 21:30 26.8 26.80 0 10.5 DAILY AVG VALUES 27.7 27.70 0 8.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 PREPARED BY DRYDEN & LARUE DATA FILE NFBRDD. POD 27-SEP-85 NORTH FORK OF BRADLEY RIVER START TIME 08/03/85 15:30 DISCHG=Gl*(DEPTH+GO) G2 GO=O Gl=O G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 08/27/85 03:30 27.6 27.60 0 8.0 08/27/85 09:30 27.6 27.60 0 6.5 08/27/85 15:30 27.2 27.20 0 7.5 08/27/85 21:30 27.6 27.60 0 11.0 DAILY AVG VALUES 27.5 27.50 0 8.3 08/28/,85 03:30 29.2 29.20 0 8.5 08/28/85 09:30 28.0 28.00 0 6.5 08/28/85 15:30 27.6 27.60 0 7.5 08/28/85 21:30 27.2 27.20 0 9.5 DAILY AVG VALUES 28.0 28.00 0 8.0 08/29/85 03:30 30.0 30.00 0 8.5 08/29/85 09:30 30.0 30.00 0 7.5 08/29/85 15:30 30.0 30.00 0 8.5 08/29/85 21:30 29.6 29.60 0 10.0 DAILY AVG VALUES 29.9 29.90 0 8.6 08/30/85 03:30 30.4 30.40 0 8.0 08/30/85 09:30 30.0 30.00 0 6.5 08/30/85 15:30 28.4 28.40 0 7.5 08/30/85 21:30 27.6 27.60 0 10.0 DAILY AVG VALUES 29.1 29.10 0 8.0 08/31/85 03:30 28.0 28.00 0 8.0 DAILY AVG VALUES 28.0 28.00 0 8.0 D-BL/107 BRADLEY LAKE HYDROELECTRIC PROJECT ENVIRONMENTAL MONITORING PROGRAM WATER QUALITY DATA REPORT Prepared for Stone & Webster Engineering Corporation 800 "A" Street Anchorage, Alaska Attention: Mr. T. Critikos by NORTHERN TECHNICAL SERVICES, INC. 750 W. 2nd Avenue, Suite 100 Anchorage, Alaska 99501 The Bradley River is currently being monitored at three locations for water temperature. As part of the 1985 environmental monitoring program instruments maintained at these locations are serviced; data storage chips retrieved; data recovered from chips (by Dryden & LaRue); and the summarized data are transmitted in report form to Stone and Webster Engineering Corporation. This is the third and final report covering the water quality task. The report covers the period from August 31 to December 28, 1985. The data are presented in four attachments: Attachment I -Riffle Reach, October 28 -December 28, 1985. Attachment II -Tree Bar Reach, August 31 -October 28, 1985. Attachment III -Tree Bar Reach, October 28 -December 28, 1985. Attachment IV -North Fork Bradley River, August 31 -October 28, 1985. A summary of the servicing record is presented below. Riffle Reach, serviced 28 October 1985 I 1215 hours This unit had been removed from the field on 31 August 1985 for servic- ing. The DMS was installed, initialized and tested on the evening of 27 October 85, and appeared to be functioning properly. The unit was reinstalled at its original location. The "ammo box" shelter was wired to the same tree as before, and the cable was wired to the stake on the bank. It was not possible to drive the perforated instrument's stake (which housed the thermistors) into the streambed, due to icy conditions on the streambank. The unit appeared to be functioning properly after servicing. Riffle Reach, serviced 28 December 1985 I 1145 hours The unit appeared to be functioning properly; "short dump" test was performed. Data storage module (DMS), batteries, and dessicant capsule 2 were replaced. The unit was initialized for noon, 28 December 85. The Datapod appeared to be functioning properly after servicing. Tree Bar Reach, serviced 28 October 1985 I 1125 hours The Datapod unit appeared to be functioning properly, but the probes had been damaged; apparently by high flows and/or riverborne debris. The probe cables were still attached to the Datapod, but they had been pulled out of their protective casing, and were lying along the stream- bank in the snow. The casing was no longer attached to the Datapod's "ammo box" shelter. It was still firmly attached to the perforated stake, which was securely embedded in the streambed, under a few inches of water. The casing was full of ice which prevented the re- installation of the probes into the casing. The probes were returned to the river, and were taped to the outside of the casing, as a temporary solution. Various alternative locations for the Datapod were noted, both upstream and downstream. The data storage module (DMS) and the dessicant capsule were replaced. The "Lo Bat" indicator was displayed; the batteries were replaced and the unit was re-initialized. The unit appeared to be functioning properly after servicing. Consideration should be given to moving it to a less vulnerable location. Tree Bar Reach, serviced 28 December 1985 I 1130 hours The Datapod unit yielded spurious readings during the "short dump" test. The cables for both probes had been severed, and the cables had been twisted and damaged. The damage appeared to have been caused by ice and/or riverborne debris. The Datapod and the probes were brought to Anchorage for repair. The "ammo box" shelter was left on site; the stake, with the probe casing still attached, remained firmly embedded in the stream gravel. 3 North Fork, serviced 28 October 1985 I 1100 hours The unit appeared to be functioning properly; "short dump" performed. The DSM was replaced; the short dump indicated that no re-initialization was necessary. An accumulation of ice around the standpipe made it impossible to read the staff gauge. The batteries were not replaced. The dessicant capsules were replaced. The unit appeared to be function- ing properly after servicing. North Fork, serviced 28 October 1985 I 1050 hours The staff gauge at this site is a steel measuring tape attached to a plastic standpipe. The lower part of the tape (near the water surface) was missing; it apparently had been damaged by the ice accumulation noted during the 28 October 85 visit. It was estimated that the staff gauge reading would have been approximately 42 ± 3 inches. The Datapod unit appeared to be functioning properly. The dessicant capsules and batteries were replaced in both the Datapod and the stage-interface unit. The DSM was replaced. Some difficulty was encountered during re- initialization: at 1100 hours, 360 minutes remained until the first reading. Henceforth, the Datapod readings will be taken one hour earlier than they had been (i.e. the new schedule is: 0500, 1100, 1700, 2300 hours). Other than this, the unit appeared to be functioning properly. Status of Datapods at end of Project Riffle Reach: This dual-channel temperature recorder appears to be functioning properly, based on the analysis of the DMS. It was serviced at Dryden & LaRue in September and re-installed in the field in October. Tree Bar Reach: This dual-channel temperature recorder was returned to the Dryden & LaRue office in December 1985 for inspection and repairs. The probes were severely damaged, and the Datapod itself appeared to yield a spurious readout during the short dump test. Analysis of the 4 DSM's showed that the unit had actually ceased proper functioning sometime prior to the October visit. The instrument should be rede- ployed as soon as possible after repairs are complete. North Fork: This stage-temperature recorder appeared to be functioning properly at the October field service visit. However, the DSM that was installed in October and retrieved in December had recorded almost no data. During installation of this DSM, the initialization sequence (short dump and test burn) was performed properly; this was confirmed by Dryden & LaRue's reading of the DSM. It seems that the DSM stopped recording data shortly after installation; many error messages were recorded. This failure may be explained by a variety of possible causes: a) faulty DSM (Dryden & LaRue will analyze); b) incorrect installation (possible, but initialization was satisfactory); c) mechanical shock to the unit after the service visit, partly dislodging the DSM (the Datapod is at the bottom of a 30-ft unstable cut bank--possible that the unit sustained a blow by falling ice or rock); and/or d) corrosion, moisture, etc. (the Datapod has not been bench-serviced since at least 1984--also, during each of the 1985 field visits, the dessicant capsule inside the unit was saturated). The DSM installed in December 1985 appeared to be properly initialized; but this impression is now suspect and should be confirmed as soon as possible. 5 Data Pod Maintenance All data pods on the Bradley River System require servicing and repair. Several units were malfunctioning during the last period. The probes appear to have suffered damage from ice and floating debris. All data pods are being removed from the field for servicing. As soon as the units are repaired they will be returned to the field and reinstalled. Spare data pods are being obtained, so that in the future, a replacement unit can be installed should an inplace unit be malfunctioning. 6 Attachment I Riffle Reach Water Quality Data October 28 -December 28, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: RRTTF START: 10/28/85 06:00 RIFFLE REACH STOP: 10/28/85 11:45 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 10/28/85 06:00 13.5 -5.0 20.4 13.8 -5.0 20.4 10/28/85 12:00 17.9 17.7 18.0 18.0 17.7 18.2 10/28/85 18:00 6.7 -5.0 18.0 6.9 -5.0 18.1 10/29/85 00:00 1.3 -2.8 1.7 1.5 -2.7 2.0 10/29/85 06:00 1.7 1.6 1.7 1.9 1.8 2.0 10/29/85 12:00 1.4 1.2 1.6 1.6 1.4 1.8 10/29/85 18:00 1.1 1.0 1.2 1.3 1.2 1.5 10/30/85 00:00 1.1 0.9 1.4 1.3 1.1 1.5 10/30/85 06:00 1.1 0.9 1.3 1.3 1.1 1.5 10/30/85 12:00 0.7 0.5 0.9 0.9 0.7 1.1 10/30/85 18:00 0.5 0.4 0.5 0.7 0.6 0.7 10/31/85 00:00 0.6 0.5 0.9 0.8 0.6 1.1 10/31/85 06:00 0.7 0.6 0.9 0.9 0.8 1.1 10/31/85 12:00 0.6 0.6 0.7 0.9 0.8 0.9 10/31/85 18:00 0.5 0.4 0.6 0.7 0.6 0.8 11/01/85 00:00 0.5 0.4 0.6 0.7 0.6 0.7 11/01/85 06:00 0.4 0.3 0.6 0.6 0.5 0.7 11/01/85 12:00 0.1 0.0 0.3 0.3 0.2 0.5 11/01/85 18:00 -0.1 -0.2 0.0 0.1 0.0 0.2 11/02/85 00:00 -0.1 -0.2 -0.1 0.1 0.0 0.2 11/02/85 06:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 11/02/85 12:00 -0.2 -0.2 -0.1 0.1 0.0 0. 1 11/02/85 18:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/03/85 00:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/03/85 06:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/03/85 12:00 -0.1 -0.2 -0.1 0. 1 0.1 0.1 11/03/85 18:00 -0.1 -0.2 -0.1 0.1 0.1 0. 1 11/04/85 00:00 -0.1 -0.2 -0.1 0.1 0.0 0. 1 11/04/85 06:00 -0.1 -0.2 -0.1 0.1 0.0 0. 1 11/04/85 12:00 -0.2 -0.2 -0.1 0. 1 0.1 0.1 11/04/85 18:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/05/85 00:00 -0.2 -0.2 -0.1 0.0 0.0 0. 1 11/05/85 06:00 -0.1 -0.2 0.0 0.1 0.0 0.2 11/05/85 12:00 0.1 0.0 0.2 0.3 0.2 0.5 11/05/85 18:00 0.3 0.1 0.5 0.5 0.4 0.7 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01120186 Processed by Dryden & LaRue DATA FILE: RRTTF START: 10128185 06:00 RIFFLE REACH STOP: 10128185 11:45 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 11106185 00:00 0.7 0.5 0.9 0.9 0.6 1.1 11106185 06:00 0.9 0.7 1.0 1.1 1.0 1.2 11106185 12:00 0.6 0.5 0.8 0.8 0.7 1.0 11106185 18:00 0.5 0.4 0.6 0.7 0.6 0.8 11107185 00:00 0.4 0.4 0.6 0.6 0.6 0.8 11107185 06:00 0.6 0.5 0.7 0.8 0.7 0.9 11107185 12:00 0.4 0.2 0.6 0.6 0.4 0.8 11107185 18:00 0.0 -0.2 0.2 0.2 0.0 0.4 11108185 00:00 -0.1 -0.2 0. 1 0.1 0.1 0.2 11108185 06:00 0.0 -0.2 0.1 0.2 o.o 0.3 11108185 12:00 -0.2 -0.2 -0.1 0.0 0.0 0.0 11108185 18:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 11109185 00:00 -0.2 -0.2 -0.1 0.1 0.0 0. 1 11109185 06:00 -0.2 -0.2 -0.2 0. 1 0.1 0.1 11109185 12:00 -0.1 -0.2 0.1 0.1 0.0 0.3 11109185 18:00 0.3 0.1 0.5 0.5 0.3 0.7 11110185 00:00 0.5 0.4 0.6 0.7 0.6 0.8 11110185 06:00 0.6 0.5 0.6 0.8 0.7 0.8 11110185 12:00 0.7 0.6 0.8 0.9 0.8 1.0 11110185 18:00 0.8 0.6 0.9 1.0 0.9 1.1 11111185 00:00 0.8 0.6 1.0 1.0 0.8 1.2 11 I 11185 06:00 1.2 1.0 1.2 1.4 1.2 1.4 11111185 12:00 1.2 1.0 1.3 1.4 1.2 1.4 11111185 18:00 1.2 1.1 1.2 1.3 1.3 1.4 11112185 00:00 1.1 0.9 1.3 1.3 1.1 1.5 11112185 06:00 1.2 1.0 1.3 1.4 1.3 1.5 11112185 12:00 0.9 0.7 1.1 1.1 0.9 1.3 11 I 12185 18:00 0.8 0.7 0.9 1.0 0.9 1.1 11113185 00:00 0.4 -0.3 0.8 0.6 -0.1 1.0 11113185 06:00 0.2 -0.1 0.5 0.4 0.1 0.7 11113185 12:00 -0.2 -0.2 -0.1 0.1 o.o 0.1 11113185 18:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11114185 00:00 -0.2 -0.5 -0.1 0.1 -0.2 0. 1 11114185 06:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11114185 12:00 -0.1 -0.2 -0.1 0.0 0.0 0. 1 11114185 18:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 D-BLI108 NORTEC FOR AtASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: RRTTF START: 10/28/85 06:00 RIFFLE REACH STOP: 10/28/85 11:45 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 11/15/85 00:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 11/15/85 06:00 -0.1 -0.2 -0.1 0.1 0.0 0. 1 11/15/85 12:00 -0.1 -0.1 -0.1 0.1 0.1 0.2 11/15/85 18:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/16/85 00:00 -0.1 -0.2 -0.1 0.1 0.1 0.2 11/16/85 06:00 -0.2 -0.2 -0.1 0.1 0.1 0.1 11/16/85 12:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/16/85 18:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/17/85 00:00 -0.1 -0.2 -0.1 0.1 0.1 0.2 11/17/85 06:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/17/85 12:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/17/85 18:00 -0.2 -0.2 -0.1 o.o o.o 0.1 11/18/85 00:00 -0.1 -0.2 -0.1 0.1 o.o 0.1 11/18/85 06:00 -0.2 -0.2 -0.2 0.1 0.0 0.1 11/18/85 12:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 11/18/85 18:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/19/85 00:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/19/85 06:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 11/19/85 12:00 -0.2 -0.2 -0.1 0.1 o.o 0.1 11/19/85 18:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 11/20/85 00:00 -0.2 -0.2 -0.1 0.0 o.o 0.1 11/20/85 06:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/20/85 12:00 -0.2 -0.2 -0.2 0.1 0.1 0.1 11/20/85 18:00 -0.2 -0.2 -0.1 0.1 0. 1 0.1 11/21/85 00:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 11/21/85 06:00 -0.2 -0.2 -0.1 0.1 0. 1 0.1 11/21/85 12:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/21/85 18:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 11/22/85 00:00 -0.2 -0.2 -0.2 0.0 0.0 0.1 11/22/85 06:00 -0.2 -0.2 -0.2 0.0 0.0 0.0 11/22/85 12:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 11/22/85 18:00 -0.2 -0.2 -0.1 0.1 0.0 0. 1 11/23/85 00:00 -0.1 -0.1 -0.1 0.1 0. 1 0. 1 11/23/85 06:00 -0.1 -0.2 -0.1 0. 1 0.0 0.1 11/23/85 12:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 11/23/85 18:00 -0.2 -0.2 -0.1 0. l 0.0 0. 1 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 DATA REPORT FOR DATAPOD DP232I -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: RRTTF START: I0/28/85 06:00 RIFFLE REACH STOP: I0/28/85 11:45 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX I1/24/85 00:00 -0.2 -0.2 -o.I O.I o.o 0.1 11/24/85 06:00 -0.2 -0.2 -0.1 0.0 0.0 0. 1 11/24/85 I2:00 -0.2 -0.2 -O.I 0.0 0.0 0. 1 11/24/85 18:00 -0.1 -0.2 -0. 1 o.o 0.0 0. 1 11/25/85 00:00 -0.2 -0.2 -O.I 0. I o.o 0.1 11/25/85 06:00 -0.1 -0.2 -0.1 O.I 0.0 0.1 11/25/85 12:00 -O.I -0.2 -O.I o.o o.o 0.0 11/25/85 I8:00 -0.1 -0.2 -O.I 0.0 o.o 0.1 11/26/85 00:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 11/26/85 06:00 -0.2 -0.2 -O.I 0.0 o.o 0.1 11/26/85 I2:00 -0.2 -0.2 -O.I 0.0 0.0 0 .I 11/26/85 I8:00 -O.I -0.2 -0.1 0.1 0.0 O.I 11/27/85 00:00 -0.2 -0.2 -0.1 o.o o.o 0 .I 11/27/85 06:00 -0.2 -0.2 -0.2 o.o 0.0 0.0 11/27/85 12:00 -0.2 -0.2 -0.2 0.0 o.o 0.0 11/27/85 I8:00 -0.2 -0.2 -0.2 0.0 0.0 0.0 11/28/85 00:00 -0.2 -0.2 -O.I 0.0 0.0 0.0 11/28/85 06:00 -0.2 -0.2 -0.2 0.0 0.0 0.0 11/28/85 I2:00 -0.2 -0.2 -0.1 0.0 0.0 0.0 11/28/85 18:00 -0.2 -0.2 -0.2 o.o 0.0 0.1 11/29/85 00:00 -0.2 -0.2 -0.1 0.0 o.o 0. 1 11/29/85 06:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 11/29/85 12:00 -0.2 -0.2 -O.I o.o 0.0 0 .I 11/29/85 I8:00 -0.1 -0.2 -O.I O.I o.o 0 .I 11/30/85 00:00 -0.1 -0.2 -0.1 0.0 0.0 0.1 11/30/85 06:00 -0.1 -0.2 -O.I O.I 0.0 0.1 11/30/85 12:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 11/30/85 18:00 -0.1 -0.2 -0.1 0. 1 0.0 0.1 12/01/85 00:00 -0.1 -0.1 -0.1 0.1 0. 1 0. 1 12/01/85 06:00 -0.1 -0.1 -0.1 0.1 O.I 0.1 12/0I/85 I2:00 -0.1 -O.I -O.I 0.1 0 .I 0 .I 12/01/85 I8:00 -0.1 -0.1 -0 .I 0.1 0.1 0.1 12/02/85 00:00 0.0 -O.I 0.0 0.1 O.I 0.1 12/02/85 06:00 -0.1 -0.1 -O.I O.I O.I 0. 1 12/02/85 12:00 -O.I -O.I -0.1 0.1 0.1 0.1 12/02/85 18:00 -0.1 -O.I -0.1 0. 1 0 .I 0.2 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: RRTTF START: 10/28/85 06:00 RIFFLE REACH STOP: 10/28/85 11:45 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MA.'C 12/03/85 00:00 -0.1 -0.2 -0.1 0. 1 0.0 0. 1 12/03/85 06:00 -0.1 -0.2 -0.1 0.1 0.0 0. 1 12/03/85 12:00 -0.1 -0.2 -0.1 0.1 0.0 0. 1 12/03/85 18:00 -0.1 -0.2 -0.1 0. 1 0.0 0.1 12/04/85 00:00 -0.1 -0.2 -0.1 0. 1 0.1 0.1 12/04/85 06:00 -0. 1 -0.1 -0. 1 0.1 0.1 0.1 12/04/85 12:00 -0.1 -0.1 -0.1 0.1 0.1 0.1 12/04/85 18:00 -0.1 --0.1 -0.1 0.1 0. 1 0.1 12/05/85 00:00 -0.1 -0.2 -0.1 0.1 0.1 0.1 12/05/85 06:00 -0.2 -0.2 -0.1 0.0 0.0 0. 1 12/05/85 12:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 12/05/85 18:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 12/06/85 00:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 12/06/85 06:00 -0.1 -0.2 -0.1 0.1 0.0 0. 1 12/06/85 12:00 -0.1 -0.2 -0.1 0.0 0.0 0.1 12/06/85 18:00 -0.1 -0.2 -0.1 0.1 0.0 0.1 12/07/85 00:00 -0.2 -0.2 -0.1 0. 1 0.1 0.1 12/07/85 06:00 -0.2 -0.2 -0.1 0.1 0. 1 0. 1 12/07/85 12:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 12/07/85 18:00 -0.2 -0.2 -0.1 0.0 0.0 0.1 12/08/85 00:00 -0.2 -0.2 -0.1 0.1 0.0 0.1 12/08/85 06:00 -0.1 -0.1 -0.1 0. 1 0. 1 0. 1 12/08/85 12:00 -0.1 -0.1 -0.0 0.1 0.1 0.2 12/08/85 18:00 -0.1 -0.2 -0.0 0. 1 0. 1 0.2 12/09/85 00:00 -0.1 -0.1 -0.1 0. 1 0. 1 0.2 12/09/85 06:00 0.0 -0.1 0.0 0.1 0.1 0.2 12/09/85 12:00 0.0 -0.1 0.0 0.2 0.1 0.2 12/09/85 18:00 -0.1 -0.2 0.0 0. 1 0.1 0.2 12/10/85 00:00 -0.1 -0.1 0.0 0. 1 0. 1 0.2 12/10/85 06:00 0.0 0.0 0. 1 0.2 0.2 0.3 12/10/85 12:00 0.2 0.1 0.2 0.3 0.3 0.4 12/10/85 18:00 0.2 0.2 0.3 0.5 0.4 0.5 12/11/85 00:00 0.2 0.2 0.3 0.4 0.4 0.5 12/11/85 06:00 0.2 0.1 0.2 0.4 0.3 0.4 12/11/85 12:00 0.1 0.0 0.2 0.3 0.2 0.4 12/11/85 18:00 0.0 -0.2 0.1 0.2 0.1 0.3 D-BL/ 108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: RRTTF START: 10/28/85 06:00 RIFFLE REACH STOP: 10/28/85 11:45 CHANNEL ONE DEG C CHANNEL TWO DEG C DATE TIME AVG MIN MAX AVG f-UN MAX 12/12/85 00:00 0.0 0.0 0.0 0.2 0. 1 0.3 12/12/85 06:00 0.2 o.o 0.3 0.4 0.3 0.5 12/12/85 12:00 0.5 0.3 0.6 0.6 0.5 0.8 12/12/85 [8:00 0.6 0.5 0.6 0.7 0.7 0.8 12/13/85 00:00 0.6 0.5 0.7 0.8 0.7 0.9 12/13/85 06:00 0.7 0.6 0.7 0.9 0.8 0.9 12/13/85 12:00 0.6 0.6 0.7 0.8 0.8 0.9 12/13/85 18:00 0.8 0.6 1.0 1.0 0.9 1.2 12/14/85 00:00 1.0 0.9 1.0 1.2 1.2 1.3 12/14/85 06:00 1.0 1.0 1.1 1.2 1.2 1.3 12/14/85 12:00 1.1 1.0 1.1 1.2 1.2 1.3 12/14/85 18:00 1.0 1.0 1.1 1.2 1.2 1.3 12/15/85 00:00 1.1 1.0 1.2 1.4 1.2 1.4 12/15/85 06:00 1.1 1.0 1.2 1.3 1.2 1.4 12/15/85 12:00 1.0 0.9 1.0 1.2 1.1 1.2 12/15/85 18:00 1.0 0.9 1.0 1.2 1.1 1.2 12/16/85 00:00 1.0 0.9 1.0 1.2 1.1 1.3 12/16/85 06:00 0.9 0.9 1.0 1.1 1.0 1.2 12/16/85 12:00 0.8 0.8 0.9 1.0 1.0 1.1 12/16/85 18:00 0.8 0.7 0.8 1.0 0.9 1.1 12/17/85 00:00 0.7 0.6 0.8 0.9 0.9 1.0 12/17/85 06:00 0.6 0.6 0.7 0.8 0.8 0.9 12/17/85 12:00 0.7 0.6 0.8 0.8 0.8 1.0 12/17/85 18:00 0.8 0.8 0.9 1.0 1.0 1.1 12/18/85 00:00 0.7 0.5 0.8 0.9 0.7 1.0 12/18/85 06:00 0.5 0.5 0.5 0.7 0.6 0.7 12/18/85 12:00 0.5 0.4 0.5 0.7 0.6 0. 7 12/18/85 18:00 0.5 0.5 0.7 0.7 0.7 0.9 12/19/85 00:00 1.0 0.7 1.3 1.3 0.8 1.5 12/19/85 06:00 1.5 1.3 1.7 1.7 1.5 1.9 12/19/85 12:00 1.6 1.4 1.7 1.8 1.6 1.9 12/19/85 18:00 1.3 1.2 1.4 1.5 1.4 1.7 12/20/85 00:00 1.0 0.9 1.2 1.2 1.1 1.4 12/20/85 06:00 1.0 0.9 1.1 1.2 1.1 1.2 12/20/85 12:00 0.9 0.8 1.1 1.1 1.0 1.2 12/20/85 18:00 1.0 0.8 1.3 1.2 1.0 1.5 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: RRTTF START: 10/28/85 06:00 RIFFLE REACH STOP: 10/28/85 11:45 CHANNEL ONE DEG C CHANNEL TWO DEG C DATE TIME AVG MIN Y,AX AVG MIN MAX 12/21/85 00:00 1.5 1.2 1.6 1.6 1.5 1.8 12/21/85 06:00 1.5 1.3 1.6 1.7 1.5 1.8 12/21/85 12:00 1.2 1.2 1.3 1.4 1.4 1.5 12/21/85 18:00 1.3 1.2 1.3 1.5 1.4 1.5 12/22/85 00:00 1.2 1.2 1.3 1.4 1.4 1.5 12/22/85 06:00 1.2 1.1 1.2 1.4 1.3 1.5 12/22/85 12:00 1.1 1.0 1.2 1.3 1.2 1.3 12/22/85 18:00 1.1 1.0 1.2 1.3 1.2 1.5 12/23/85 00:00 1.2 1.2 1.3 1.4 1.4 1.5 12/23/85 06:00 1.3 1.2 1.4 1.5 1.4 1.6 12/23/85 12:00 1.3 1.1 1.5 1.5 1.3 1.6 12/23/85 18:00 1.1 1.0 1.2 1.3 1.2 1.4 12/24/85 00:00 1.2 1.1 1.3 1.4 1.3 1.5 12/24/85 06:00 1.2 1.2 1.3 1.4 1.4 1.5 12/24/85 12:00 1.3 1.2 1.3 1.5 1.4 1.5 12/24/85 18:00 1.0 0.8 1.2 1.2 1.1 1.5 12/25/85 00:00 1.1 1.0 1.1 1.3 1.2 1.4 12/25/85 06:00 0.9 0.8 1.0 1.1 1.0 1.2 12/25/85 12:00 0.9 0.8 0.9 1.1 1.0 1.1 12/25/85 18:00 0.9 0.9 1.0 1.1 1.1 1.2 12/26/85 00:00 1.1 1.0 1.1 1.3 1.2 1.3 12/26/85 06:00 0.5 -0.1 1.0 0.7 0.1 1.2 12/26/85 12:00 1.0 0.4 1.2 1.2 0.6 1.4 12/26/85 18:00 1.3 1.2 1.3 1.4 1.4 1.5 12/27/85 00:00 1.4 1.2 1.5 1.5 1.4 1.6 12/27/85 06:00 1.5 1.4 1.5 1.6 1.6 1.7 12/27/85 12:00 1.4 1.4 1.5 1.6 1.6 1.6 12/27/85 18:00 1.4 1.4 1.5 1.6 1.5 1.6 12/28/85 00:00 1.5 1.4 1.5 1.6 1.6 1.7 12/28/85 06:00 1.4 1.3 1.5 1.5 1.5 1.6 12/28/85 12:00 1.3 1.2 1.3 1.5 1.4 1.5 D-BL/108 Attachment II Tree Bar Reach Water Quality Data August 31 -October 28, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 08/31/85 12:00 8.4 8.3 8.5 8.6 8.6 8.7 08/31/85 18:00 8.8 8.4 9.0 8.8 8.6 8.9 09/01/85 00:00 8.7 8.6 8.9 8.8 8.8 8.9 09/01/85 06:00 8.5 8.5 8.6 8.8 8.7 8.8 09/01/85 12:00 8.4 8.3 8.5 8.8 8.8 8.8 09/01/85 18:00 8.7 8.5 8.8 8.8 8.7 8.9 09/02/85 00:00 8.4 7.9 8.6 8.8 8.7 8.9 09/02/85 06:00 7.6 7.5 7.9 8.6 8.5 8.8 09/02/85 12:00 7.6 7.5 7.8 8.5 8.4 8.6 09/02/85 18:00 8.2 7.7 8.4 8.5 8.4 8.5 09/03/85 00:00 8.0 7.7 8.4 8.4 8.3 8.5 09/03/85 06:00 7.6 7.6 7.7 8.3 8.2 8.3 09/03/85 12:00 7.8 7.6 8. 1 8.3 8.2 8.3 09/03/85 18:00 8.3 8.0 8.4 8.3 8.3 8.4 09/04/85 00:00 8.1 7.8 8.3 8.3 8.2 8.4 09/04/85 06:00 7.4 7.2 7.8 8.2 8. 1 8.3 09/04/85 12:00 7.2 7.0 7.7 8.1 8.0 8.2 09/04/85 18:00 8.3 7.7 8.6 8.2 8. 1 8.3 09/05/85 00:00 7.9 7.4 8.4 8.2 8. 1 8.2 09/05/85 06:00 7. 1 6.8 7.4 8.0 7.8 8. 1 09/05/85 12:00 6.8 6.7 7.1 7.8 7.8 7.9 09/05/85 18:00 8.0 7.2 8.3 8.0 7.8 8.0 09/06/85 00:00 7.9 7.6 8.2 8.0 7.9 8.0 09/06/85 06:00 7.2 6.9 7.6 7.9 7.8 8.0 09/06/85 12:00 6.9 6.8 7.3 7.8 7.7 7.8 09/06/85 18:00 8.2 7.4 8.9 7.9 7.8 8. 1 09/07/85 00:00 8.5 8.1 8.9 8. 1 8.0 8 .1 09/07/85 06:00 8.0 7.9 8.1 8.1 8.0 8. 1 09/07/85 12:00 8.0 7.9 8.3 8.2 8.1 8.3 09/07/85 18:00 9.0 8.2 9.3 8.4 8.3 8.5 09/08/85 00:00 9.1 8.8 9.3 8.5 8.5 8.6 09/08/85 06:00 8.6 8.4 8.8 8.7 8.6 8.7 09/08/85 12:00 8.4 8.3 8.5 8.7 8.7 8.9 09/08/85 18:00 8.5 8.4 8.5 8.8 8.8 8.9 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 09/09/85 00:00 8. 1 7.6 8.5 8.8 8.6 8.9 09/09/85 06:00 7.3 7.2 7.7 8.5 8.5 8.7 09/09/85 12:00 7.4 7.3 7.7 8.4 8.4 8.5 09/09/85 18:00 8. 1 7.6 8.3 8.4 8.3 8.4 09/10/85 00:00 7.7 7.2 8.3 8.3 8 .1 8.4 09/10/85 06:00 7.1 7. 1 7.2 8.0 8.0 8. 1 09/10/85 12:00 7.2 7.1 7.3 8.0 7.9 8.0 09/10/85 18:00 7.9 7.4 8.3 8.0 7.9 8.1 09/11/85 00:00 7.6 7.3 7.9 8.0 7.9 8. 1 09/11/85 06:00 7.0 6.9 7.3 7.9 7.8 7.9 09/11/85 12:00 6.8 6.7 7.2 7.7 7.7 7.8 09/11/85 18:00 7.9 7.2 8.2 7.8 7.7 7.9 09/12/85 00:00 7.8 7.5 8.1 7.9 7.8 7.9 09/12/85 06:00 7.0 6.9 7.4 7.7 7.7 7.9 09/12/85 12:00 7.1 6.9 7.4 7.7 7.6 7.8 09/12/85 18:00 8.0 7.4 8.4 7.8 7.7 7.9 09/13/85 00:00 8.1 7.8 8.3 7.9 7.9 8.0 09/13/85 06:00 7.8 7.8 7.9 8.0 7.9 8.0 09/13/85 12:00 8.0 7.8 8.2 8.0 7.9 8.2 09/13/85 18:00 8.5 8.2 8.7 8.2 8.1 8.3 09/14/85 00:00 8.6 8.5 8.6 8.3 8.3 8.4 09/14/85 06:00 8.6 8.5 8.6 8.4 8.3 8.5 09/14/85 12:00 8.5 8.5 8.6 8.5 8.5 8.5 09/14/85 18:00 8.8 8.5 9.0 8.6 8.5 8.7 09/15/85 00:00 8.5 8.2 8.9 8.7 8.6 8.7 09/15/85 06:00 7.9 7.6 8.2 8.7 8.6 8.7 09/15/85 12:00 7.6 7.5 7.7 8.5 8.5 8.6 09/15/85 18:00 8.0 7.7 8.2 8.5 8.5 8.6 09/16/85 00:00 7.6 7.5 8.0 8.4 8.3 8.5 09/16/85 06:00 7.2 7.1 7.5 8.2 8.1 8.3 09/16/85 12:00 7.1 7 .o 7.2 8.0 8.0 8.2 09/16/85 18:00 7.6 7.2 7.8 8.0 8.0 8.1 09/17/85 00:00 7.3 6.9 7.6 7.9 7.8 8.0 09/17/85 06:00 6.7 6.5 6.9 7.7 7.6 7.8 09/17/85 12:00 6.5 6.4 6.6 7.6 7.5 7.7 09/17/85 18:00 7.2 6.7 7.5 7.6 7.5 7.6 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 DATA REPORT FOR DATAPOD DP2321-0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG HIN MAX -- 09/18/85 00:00 7.2 7. 1 7.3 7.5 7.5 7.6 09/18/85 06:00 7.0 6.9 7. 1 7.5 7.4 7.5 09/18/85 12:00 6.8 6.8 6.9 7.5 7.4 7.5 09/18/85 18:00 7.2 6.8 7.6 7.5 7.4 7.6 09/19/85 00:00 7.5 7.4 7.6 7.5 7.5 7.6 09/19/85 06:00 7.4 7.4 7.4 7.6 7.5 7.6 09/19/85 12:00 7.3 7.2 7.5 7.6 7.6 7.7 09/19/85 18:00 7.7 7.4 7.9 7.7 7.6 7.8 09/20/85 00:00 7.3 7.1 7.6 7.8 7.7 7.8 09/20/85 06:00 6.8 6.5 7.1 7.7 7.6 7.8 09/20/85 12:00 6.4 6.3 6.5 7.5 7.4 7.7 09/20/85 18:00 7.2 6.6 7.5 7.6 7.5 7.6 09/21/85 00:00 6.9 6.5 7.3 7.5 7.3 7.6 09/21/85 06:00 6.3 6.1 6.6 7.3 7.1 7.4 09/21/85 12:00 6.1 6.0 6.4 7.1 7.0 7.1 09/21/85 18:00 7.0 6.4 7.2 7.2 7.1 7.2 09/22/85 00:00 7.0 6.8 7.2 7.2 7.2 7.3 09/22/85 06:00 6.8 6.7 6.9 7.2 7.1 7.2 09/22/85 12:00 6.7 6.7 6.9 7.1 7.1 7.2 09/22/85 18:00 7.3 6.9 7.5 7.2 7.1 7.3 09/23/85 00:00 7.4 7.2 7.5 7.4 7.3 7.4 09/23/85 06:00 7.1 6.9 7.2 7.4 7.3 7.4 09/23/85 12:00 6.8 6.7 7.0 7.3 7.3 7.4 09/23/85 18:00 7.6 6.9 8.0 7.5 7.4 7.6 09/24/85 00:00 7.8 7.6 8.0 7.6 7.5 7.6 09/24/85 06:00 7.5 7.4 7.6 7.6 7.6 7.7 09/24/85 12:00 7.4 7.3 7.4 7.7 7.6 7.7 09/24/85 18:00 7.4 7.2 7.6 7.8 7.7 7.8 09/25/85 00:00 6.9 6.6 7.2 7.7 7.7 7.8 09/25/85 06:00 6.2 5.9 6.6 7.5 7.4 7.6 09/25/85 12:00 5.8 5.7 5.9 7.3 7.2 7.4 09/25/85 18:00 6.6 6.0 7.0 7.3 7.2 7.3 09/26/85 00:00 6.8 6.6 7.0 7.3 7.2 7.3 09/26/85 06:00 6.5 6.4 6.7 7.1 7.1 7.2 09/26/85 12:00 6.4 6.4 6.5 7.0 7.0 7.1 09/26/85 18:00 6.7 6.5 6.8 7.0 7.0 7.1 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 09/27/85 00:00 7.0 6.8 7.3 7.1 7.0 7.2 09/27/85 06:00 7.5 7.3 7.6 7.1 7.1 7.2 09/27/85 12:00 7.5 7.4 7.6 7.3 7.2 7.7 09/27/85 18:00 7.1 6.8 7.5 8.1 7.8 8.6 09/28/85 00:00 -1.0 -5.0 7.1 -2.8 -5.0 9.4 09/28/85 06:00 -5 .o -5.0 -5.0 -4.9 -5 .o -4.8 09/28/85 12:00 -5.0 -5.0 -5.0 -4.9 -5 .o -4.8 09/28/85 18:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 09/29/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 09/29/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 09/29/85 12:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 09/29/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 09/30/85 00:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 09/30/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.9 09/30/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 09/30/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/01/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/01/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/01/85 12:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 10/01/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/02/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/02/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/02/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/02/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/03/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/03/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/03/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/03/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/04/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/04/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/04/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/04/85 18:00 -4.3 -5.0 20.4 -4.8 -4.8 -4.8 10/05/85 00:00 -2.5 -5.0 20.4 -4.8 -4.8 -4.8 10/05/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/05/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/05/85 18:00 -4.3 -5.0 20.4 -4.8 -4.8 -4.8 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 10/06/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/06/85 06:00 -3.9 -5.0 20.4 -4.8 -4.8 -4.8 10/06/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/06/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/07/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/07/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/07/85 12:00 1.0 -5.0 20.4 -4.8 -4.8 -4.8 10/07/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/08/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/08/85 06:00 -4.6 -5.0 20.4 -4.8 -4.8 -4.8 10/08/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/08/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/09/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/09/85 06:00 -2.9 -5.0 20.4 -4.8 -4.8 -4.8 10/09/85 12:00 -3.9 -5.0 20.4 -4.8 -4.8 -4.8 10/09/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/10/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/10/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/10/85 12:00 -4.6 -5.0 20.4 -4.8 -4.8 -4.8 10/10/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/11/85 00:00 -4.6 -5.0 20.4 -4.8 -4.8 -4.8 10/11/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/11/85 12:00 -3.6 -5.0 20.4 -4.8 -4.8 -4.8 10/11/85 18:00 -5 .o -5.0 -5.0 -4.8 -4.8 -4.8 10/12/85 00:00 -3.9 -5.0 20.4 -4.8 -4.8 -4.8 10/12/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/12/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/12/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/13/85 00:00 -4.6 -5.0 20.4 -4.8 -4.8 -4.8 10/13/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/13/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/13/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/14/85 00:00 -3.9 -5.0 20.4 -4.8 -4.8 -4.8 10/14/85 06:00 -2.9 -5.0 20.4 -4.8 -5.0 -4.8 10/14/85 12:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 10/14/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 DATA REPORT FOR DATAPOD DP2321-0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 10/15/85 00:00 0.6 -5.0 20.4 -4.8 -4.8 -4.8 10/15/85 06:00 -1.1 -5.0 20.4 -4.8 -4.8 -4.8 10/15/85 12:00 0.3 -5.0 20.4 -4.8 -4.8 -4.8 10/15/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/16/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/16/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/16/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/16/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/17/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/17/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/17/85 12:00 -3.6 -5.0 20.4 -4.8 -4.8 -4.8 10/17/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/18/85 00:00 -4.3 -5.0 20.4 -4.8 -4.8 -4.8 10/18/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/18/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/18/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 10/19/85 00:00 -1.5 -5.0 20.4 -4.8 -5.0 -4.8 10/19/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/19/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/19/85 18:00 -4.3 -5.0 20.4 -5.0 -5.0 -5.0 10/20/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/20/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/20/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/20/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/21/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/21/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/21/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/21/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/22/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/22/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/22/85 12:00 -1.8 -5.0 20.4 -5.0 -5.0 -5.0 10/22/85 18:00 -3.9 -5.0 20.4 -5.0 -5.0 -5.0 10/23/85 00:00 -3.6 -5.0 20.4 -5.0 -5.0 -5.0 10/23/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/23/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/23/85 18:00 -3.6 -5.0 20.4 -5.0 -5.0 -5.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTE START: 08/31/85 12:00 TREE BAR REACH STOP: 10/28/85 11:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 10/24/85 00:00 -4.3 -5.0 20.4 -5.0 -5.0 -5.0 10/24/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/24/85 12:00 4.2 -5.0 20.4 -5.0 -5.0 -5.0 10/24/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/25/85 00:00 -4.3 -5.0 20.4 -5.0 -5.0 -5.0 10/25/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/25/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/25/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/26/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/26/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/26/85 12:00 4.2 -5.0 20.4 -5.0 -5.0 -5.0 10/26/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/27/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/27/85 06:00 -0.1 -5.0 20.4 -5.0 -5.0 -5.0 10/27/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/27/85 18:00 -2.9 -5.0 20.4 -5.0 -5.0 -5.0 10/28/85 00:00 -4.6 -5.0 20.4 -5.0 -5.0 -5.0 10/28/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/28/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 D-BL/107 Attachment III Tree Bar Reach Water Quality Data October 28 -December 28, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TE¥.P/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 10/28/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/28/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.9 10/29/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/29/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/29/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/29/85 18:00 -5.o -5 .o -5.0 -5.0 -5.o -5 .o 10/30/85 00:00 -5.0 -5.0 -5.0 -5.o -5.0 -4.8 10/30/85 06:00 -5.0 -5.o -5.0 -5.0 -5.0 -5.0 10/30/85 12:00 -5.0 -5.0 -5.0 -5'.0 -5.0 -5.0 10/30/85 18:00 -5.0 -5 .o -5.0 -5.0 -5.0 -5.0 10/31/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/31/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 10/31/85 12:00 -4.6 -5.o 20.4 -5.0 -5.0 -5.o 10/31/85 18:00 -3.6 -5.0 20.4 -5.0 -5.0 -5.0 11/01/85 00:00 -1.8 -5.0 20.4 -5.0 -5.0 -5.0 11/01/85 06:00 -4.3 -5.0 20.4 -5.o -5.0 -5.0 11/01/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/01/85 18:00 -3.6 -5.0 20.4 -5.0 -5.0 -5.0 11/02/85 00:00 -3.6 -5.0 20.4 -5.0 -5.0 -5.0 11/02/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/02/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/02/85 18:00 -5.o -5.0 -5.0 -5.0 -5.0 -5.0 11/03/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/03/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/03/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/03/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/04/85 00:00 -4.6 -5.0 20.4 -5.0 -5.0 -5.0 11/04/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/04/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/04/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/05/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/05/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/05/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/05/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 11/06/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/06/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/06/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/06/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/07/85 00:00 -3.2 -5.0 20.4 -5.0 -5.0 -5.0 11/07/85 06:00 -1.5 -5.0 20.4 -5.0 -5.0 -5.0 11/07/85 12:00 1.7 -5.0 20.4 -5.0 -5.0 -5.0 11/07/85 18:00 -3.9 -5.0 20.4 -5.0 -5.0 -5.0 11/08/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/08/85 06:00 0.6 -5.0 20.4 -5.0 -5.0 -5.0 11/08/85 12:00 -4.3 -5.0 20.4 -5.0 -5.0 -5.0 11/08/85 18:00 -3.2 -5.0 20.4 -5.0 -5.0 -5.0 11/09/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/09/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/09/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/09/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/10/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/10/85 06:00 -4.6 -5.0 20.4 -5.0 -5.0 -5.0 11/10/85 12:00 -3.2 -5.0 20.4 -5.0 -5.0 -5.0 11/10/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/11/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/11/85 06:00 -2.5 -5.0 20.4 -5.0 -5.0 -5.0 11/11/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/11/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/12/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/12/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/12/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/12/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/13/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/13/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/13/85 12:00 8.8 -5.0 20.4 -5.0 -5.0 -5.0 11/13/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/14/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/14/85 06:00 7.3 -5.0 20.4 -5.0 -5.0 -5.0 11/14/85 12:00 -1.8 -5.0 20.4 -5.0 -5.0 -5.0 11/14/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 D-BL/108 NORTEC FOR ALASKA PO\.JER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MA.."{ 11/15/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/15/8.5 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/15/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/15/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/16/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/16/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/16/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/16/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/17/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/17/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/17/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/17/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/18/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/18/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/18/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/18/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/19/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/19/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/19/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/19/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/20/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/20/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/20/85 12:00 -5.0 -5.0 -5 .o -5.0 -5.0 -5.0 11/20/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -0.3 11/21/85 00:00 2.1 -5.0 20.4 -5.0 -5.0 -5.0 11/21/85 06:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 11/21/85 12:00 -3.9 -5.0 20.4 1.3 -5.0 8.3 11/21/85 18:00 6.3 -5.0 20.4 8.2 4.9 15.1 11/22/85 00:00 -5.0 -5.0 -5.0 -0.9 -3.2 5.5 11/22/85 06:00 -3.2 -5.0 20.4 -1.1 -3.6 1.6 11/22/85 12:00 -5.0 -5.0 -5.0 -4.3 -5.0 -3.2 11/22/85 18:00 -5.0 -5.0 -5.0 -4.3 -5.0 -3.2 11/23/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/23/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/23/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/23/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 DATA REPORT FOR DATAPOD DP2321 -0.1 DEC C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MA.X AVG MIN MAX 11/24/85 00:00 0.6 -5.0 20.4 -4.9 -5.0 -4.8 11/24/85 06:00 1.7 -5.0 20.4 -4.8 -4.8 -4.8 11/24/85 12:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 11/24/85 18:00 0.6 -5.0 20.4 -4.9 -5.0 -4.8 11/25/85 00:00 4.9 -5.0 20.4 -4.8 -5.0 -4.8 11/25/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 11/25/85 12:00 -1.8 -5.0 20.4 -4.8 -5.0 -4.8 11/25/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.8 11/26/85 00:00 -3.9 -5.0 20.4 -3.5 -5.0 -0.6 11/26/85 06:00 -5.0 -5.0 -5.0 -4.8 -5.0 0.8 11/26/85 12:00 -5.0 -5.0 -5.0 -4.6 -5.0 3.7 11/26/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 11/27/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 11/27/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 11/27/85 12:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 11/27/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/28/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/28/85 06:00 4.2 -5.0 20.4 -5.0 -5.0 -5.0 11/28/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/28/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/29/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/29/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/29/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/29/85 18:00 -5.0 ..:5.0 -5.0 -5.0 -5.0 -5.0 11/30/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/30/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 11/30/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.9 11/30/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.9 12/01/85 00:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/01/85 06:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/01/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/01/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/02/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/02/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/02/85 12:00 -4.3 -5.0 20.4 -4.8 -4.8 -4.8 12/02/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER Ol/20/8f> Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 12/03/85 00:00 -3.9 -5.0 20.4 -4.8 -4.8 -4.8 12/03/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/03/85 12:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/03/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.9 12/04/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/04/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/04/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/04/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/05/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/05/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/05/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/05/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/06/85 00:00 -3.2 -5.0 20.4 -5.0 -5.0 -5.0 12/06/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/06/85 12:00 -5.0 -5.0 -5.0 .... 5.0 -5.0 -5.0 12/06/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/07/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/07/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/07/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/07/85 18:00 4.5 -5.0 20.4 -5.0 -5.0 -5.0 12/08/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/08/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/08/85 12:00 1.4 -5.0 20.4 -5.0 -5.0 -5.0 12/08/85 18:00 -4.3 -5.0 20.4 -4.8 -5.0 -4.8 12/09/85 00:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/09/85 06:00 -5.0 -5.0 -5.0 -4.8 -4.9 -4.8 12/09/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.8 12/09/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/10/85 00:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/10/85 06:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/10/85 12:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/10/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/11/85 00:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/11/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/11/85 12:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/11/85 18:00 -3.6 -5.0 20.4 -4.8 -4.8 -4.8 D-BL/108 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG C DATE TIME AVG MIN MAX AVG MIN MAX 12/12/85 00:00 2.4 -5.0 20.4 -4.8 -5.0 -4.8 12/12/85 06:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/12/85 12:00 -3.9 -5.0 20.4 -4.9 -5.0 -4.8 12/12/85 18:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/13/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.8 12/13/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/13/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.8 12/13/85 18:00 -2.5 -5.0 20.4 -5.0 -5.0 -4.8 12/14/85 00:00 -2.9 -5.0 20.4 -5.0 -5.0 -5.0 12/14/85 06:00 -3.9 -5.0 20.4 -5.0 -5.0 -5.0 12/14/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/14/85 18:00 -3.6 -5.0 20.4 -5.0 -5.0 -4.8 12/15/85 00:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/15/85 06:00 -4.6 -5.0 20.4 -4.9 -5.0 -4.8 12/15/85 12:00 -5.0 -5.0 -5.0 -4.8 -5.0 -1.0 12/15/85 18:00 4.5 -5.0 20.4 -4.9 -5.0 -4.8 12/16/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.8 12/16/85 06:00 -4.3 -5.0 20.4 -5.0 -5.0 -5.0 12/16/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/16/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/17/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/17/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/17/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/17/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/18/85 00:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/18/85 06:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/18/85 12:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/18/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.8 12/19/85 00:00 -4.3 -5.0 20.4 -4.8 -5.0 -4.8 12/19/85 06:00 -4.6 -5.0 20.4 -4.9 -5.0 -4.8 12/19/85 12:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/19/85 18:00 -5.0 -5.0 -5.0 -4.8 -4.8 -4.8 12/20/85 00:00 -3.2 -5.0 20.4 -4.8 -4.8 -4.8 12/20/85 06:00 -4.6 -5.0 20.4 -4.9 -5.0 -4.8 12/20/85 12:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/20/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 D-BL/108 NORTEC FOR ALASf~ POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 DATA REPORT FOR DATAPOD DP2321 -0.1 DEG C TEMP/TEMP RECORDER 01/20/86 Processed by Dryden & LaRue DATA FILE: TBRTTF START: 10/28/85 12:00 TREE BAR REACH STOP: 01/16/86 13:25 CHANNEL ONE -DEG C CHANNEL TWO -DEG c DATE TIME AVG MIN MAX AVG MIN MAX 12/21/85 00:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/21/85 06:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/21/85 12:00 -3.9 -5.0 20.4 -4.9 -5.0 -4.8 12/21/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -4.9 12/22/85 00:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 12/22/85 06:00 -2.5 -5.0 20.4 -4.9 -5.0 -4.8 12/22/85 12:00 -5.0 -5.0 -5.0 -3.2 -5.0 5.2 12/22/85 18:00 -5.0 -5.0 -5.0 -1.5 -5.0 6.4 12/23/85 00:00 -5.0 -5.0 -5.0 -4.8 -5.0 -3.2 12/23/85 06:00 -3.9 -5.0 20.4 -3.1 -5.0 2.8 12/23/85 12:00 -3.9 -5.0 -2.4 -4.9 -5.0 -4.8 12/23/85 18:00 -0.4 -5.0 20.4 -4.9 -5.0 -4.8 12/24/85 00:00 -4.3 -5.0 20.4 -4.8 -5.0 -4.8 12/24/85 06:00 -3.6 -5.0 20.4 -4.8 -5.0 -4.8 12/24/85 12:00 -5.0 -5.0 -5.0 -4.8 -5.0 -3.7 12/24/85 18:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/25/85 00:00 -5.0 -5.0 -5.0 -4.9 -5.0 -4.8 12/25/85 06:00 -5.0 -5.0 -5.0 -3.0 -5.0 7.7 12/25/85 12:00 -5.0 -5.0 -5.0 -3.3 -5.0 -0.7 12/25/85 18:00 0.3 -5.0 -2.4 -5.0 -5.0 -5.0 12/26/85 00:00 -4.6 -5.0 20.4 -5.0 -5.0 -4.8 12/26/85 06:00 -1.1 -5.0 20.4 -4.9 -5.0 -4.8 12/26/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/26/85 18:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/27/85 00:00 -3.2 -5.0 20.4 -4.9 -5.0 -4.8 12/27/85 06:00 -4.3 -5.0 20.4 -4.9 -5.0 -4.8 12/27/85 12:00 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0 12/27/85 18:00 -4.3 -5.0 20.4 -5.0 -5.0 -5.0 12/28/85 00:00 -3.2 -5.0 20.4 -5.0 -5.0 -4.8 12/28/85 06:00 -5.0 -5.0 -5.0 -4.8 -5.0 -4.8 D-BL/108 Attachment IV North Fork Bradley River Water Quality Data August 31 -October 28, 1985 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 1 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 08/31/85 09:45 26.4 26.40 0 7.5 08/31/85 15:45 28.8 28.80 0 8.0 08/31/85 21:45 31.6 31.60 0 9.5 DAILY AVG VALUES 28.93 0 8.3 09/01/85 03:45 35.2 35.20 0 9.0 09/01/85 09:45 38.8 38.80 0 8.5 09/01/85 15:45 37.6 37.60 0 8.5 09/01/85 21:45 37.6 37.60 0 9.0 DAILY AVG VALUES 37.30 0 8.8 09/02/85 03:45 36.4 36.40 0 7.0 09/02/85 09:45 33.6 33.60 0 6.5 09/02/85 15:45 32.0 32.00 0 7.0 09/02/85 21:45 31.2 31.20 0 8.5 DAILY AVG VALUES 33.30 0 7.3 09/03/85 03:45 30.8 30.80 0 7.0 09/03/85 09:45 29.2 29.20 0 6.5 09/03/85 15:45 28.4 28.40 0 7.5 09/03/85 21:45 26.8 26.80 0 8.0 DAILY AVG VALUES 28.80 0 7.3 09/04/85 03:45 26.4 26.40 0 6.5 09/04/85 09:45 25.2 25.20 0 5.5 09/04/85 15:45 24.4 24.40 0 6.5 09/04/85 21:45 24.0 24.00 0 9.0 DAILY AVG VALUES 25.00 0 6.9 09/05/85 03:45 25.2 25.20 0 7.0 09/05/85 09:45 23.6 23.60 0 5.5 09/05/85 15:45 23.2 23.20 0 6.0 09/05/85 21:45 22.4 22.40 0 9.0 DAILY AVG VALUES 23.60 0 6.9 09/06/85 03:45 22.8 22.80 0 8.0 09/06/85 09:45 22.8 22.80 0 5.5 09/06/85 15:45 21.6 21.60 0 6.5 09/06/85 21:45 21.6 21.60 0 9.5 DAILY AVG VALUES 22.20 0 7.4 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 2 DATA REPORT FOR DATAPCD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 09/07/85 03:45 22.4 22.40 0 8.5 09/07/85 09:45 22.8 22.80 0 7.5 09/07/85 15:45 22.0 22.00 0 8.5 09/07/85 21:45 24.8 24.80 0 10.5 DAILY AVG VALUES 23.00 0 8.8 09/08/85 03:45 27.6 27.60 0 9.5 09/08/85 09:45 29.2 29.20 0 8.5 09/08/85 15:45 30.4 30.40 0 8.5 09/08/85 21:45 29.6 29.60 0 8.0 DAILY AVG VALUES 29.20 0 8.6 09/09/85 03:45 28.8 28.80 0 6.5 09/09/85 09:45 27.2 27.20 0 6.0 09/09/85 15:45 25.6 25.60 0 6.5 09/09/85 21:45 24.8 24.80 0 7.5 DAILY AVG VALUES 26.60 0 6.6 09/10/85 03:45 24.0 24.00 0 6.5 09/10/85 09:45 23.2 23.20 0 6.0 09/10/85 15:45 22.4 22.40 0 6.5 09/10/85 21:45 21.6 21.60 0 8.0 DAILY AVG VALUES 22.80 0 6.8 09/11/85 03:45 21.6 21.60 0 6.5 09/11/85 09:45 21.2 21.20 0 5.0 09/11/85 15:45 20.4 20.40 0 5.5 09/11/85 21:45 20.0 20.00 0 8.0 DAILY AVG VALUES 20.80 0 6.3 09/12/85 03:45 20.0 20.00 0 6.5 09/12/85 09:45 19.2 19.20 0 5.5 09/12/85 15:45 18.8 18.80 0 6.0 09/12/85 21:45 18.4 18.40 0 8.0 DAILY AVG VALUES 19.10 0 6.5 09/13/85 03:45 18.4 18.40 0 7.5 09/13/85 09:45 18.4 18.40 0 7.0 09/13/85 15:45 18.4 18.40 0 7.5 09/13/85 21:45 18.8 18.80 0 9.0 DAILY AVG VALUES 18.50 0 7.8 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 3 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 09/14/85 03:45 20.4 20.40 0 9.0 09/14/85 09:45 27.6 27.60 0 9.0 09/14/85 15:45 34.4 34.40 0 9.0 09/14/85 21:45 36.4 36.40 0 9.5 DAILY AVG VALUES 29.70 0 9. 1 09/15/85 03:45 36.0 36.00 0 8.0 09/15/85 09:45 33.2 33.20 0 7.0 09/15/85 15:45 32.0 32.00 0 7.0 09/15/85 21:45 30.4 30.40 0 7.5 DAILY AVG VALUES 32.90 0 7.4 09/16/85 03:45 29.2 29.20 0 6.5 09/16/85 09:45 27.6 27.60 0 5.5 09/16/85 15:45 25.2 25.20 0 6.0 09/16/85 21:45 24.8 24.80 0 7.0 DAILY AVG VALUES 26.70 0 6.3 09/17/85 03:45 23.6 23.60 0 5.0 09/17/85 09:45 22.0 22.00 0 3.5 09/17/85 15:45 21.6 21.60 0 4.0 09/17/85 21:45 21.2 21.20 0 6.0 DAILY AVG VALUES 22.10 0 4.6 09/18/85 03:45 20.8 20.80 0 5.5 09/18/85 09:45 20.8 20.80 0 5.0 09/18/85 15:45 22.8 22.80 0 5.0 09/18/85 21:45 23.6 23.60 0 6.5 DAILY AVG VALUES 22.00 0 5.5 09/19/85 03:45 22.0 22.00 0 6.5 09/19/85 09:45 22.0 22.00 0 6.0 09/19/85 15:45 22.4 22.40 0 6.0 09/19/85 21:45 22.4 22.40 0 6.5 DAILY AVG VALUES 22.20 0 6.3 09/20/85 03:45 22.8 22.80 0 5.5 09/20/85 09:45 21.6 21.60 0 4.0 09/20/85 15:45 21.2 21.20 0 4.0 09/20/85 21:45 20.8 20.80 0 5.5 DAILY AVG VALUES 21.60 0 4.8 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 4 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 09/21/85 03:45 20.4 20.40 0 4.5 09/21/85 09:45 20.0 20.00 0 2.5 09/21/85 15:45 19.6 19.60 0 3.5 09/21/85 21:45 19.6 19.60 0 5.5 DAILY AVG VALUES 19.90 0 4.0 09/22/85 03:45 19.2 19.20 0 5.5 09/22/85 09:45 19.2 19.20 0 5.0 09/22/85 15:45 20.0 20.00 0 5.5 09/22/85 21:45 19.2 19.20 0 7.0 DAILY AVG VALUES 19.40 0 5.8 09/23/85 03:45 19.2 19.20 0 6.5 09/23/85 09:45 19.2 19.20 0 5.5 09/23/85 15:45 18.4 18.40 0 6.0 09/23/85 21:45 18.0 18.00 0 7.5 DAILY AVG VALUES 18.70 0 6.4 09/24/85 03:45 18.4 18.40 0 7.5 09/24/85 09:45 18.4 18.40 0 7.0 09/24/85 15:45 20.0 20.00 0 7.0 09/24/85 21:45 21.6 21.60 0 6.5 DAILY AVG VALUES 19.60 0 7.0 09/25/85 03:45 20.8 20.80 0 5.0 09/25/85 09:45 20.4 20.40 0 3.5 09/25/85 15:45 20.0 20.00 0 4.0 09/25/85 21:45 19.6 19.60 0 5.5 DAILY AVG VALUES 20.20 0 4.5 09/26/85 03:45 19.2 19.20 0 5.5 09/26/85 09:45 18.8 18.80 0 5.0 09/26/85 15:45 20.0 20.00 0 5.0 09/26/85 21:45 28.4 28.40 0 6.5 DAILY AVG VALUES 21.60 0 5.5 09/27/85 03:45 34.4 34.40 0 7.5 09/27/85 09:45 45.6 45.60 0 8.0 09/27/85 15:45 52.8 52.80 0 7.5 09/27/85 21 :45 65.2 65.20 0 6.5 DAILY AVG VALUES 49.50 0 7.4 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 5 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 09/28/85 03:45 59.2 59.20 0 6.0 09/28/85 09:45 55.2 55.20 0 6.0 09/28/85 15:45 51.2 51.20 0 6.0 09/28/85 21:45 49.6 49.60 0 6.5 DAILY AVG VALUES 53.80 0 6.1 09/29/85 03:45 48.4 48.40 0 6.0 09/29/85 09:45 58.0 58.00 0 6.0 09/29/85 15:45 57.2 57.20 0 7.0 09/29/85 21:45 53.6 53.60 0 6.5 DAILY AVG VALUES 54.30 0 6.4 09/30/85 03:45 50.0 50.00 0 6.0 09/30/85 09:45 48.8 48.80 0 5.5 09/30/85 15:45 47.6 47.60 0 6.0 09/30/85 21:45 44.4 44.40 0 6.0 DAILY AVG VALUES 47.70 0 5.9 10/01/85 03:45 42.4 42.40 0 4.5 10/01/85 09:45 40.8 40.80 0 4.0 10/01/85 15:45 38.8 38.80 0 5.0 10/01/85 21:45 37.6 37.60 0 5.5 DAILY AVG VALUES 39.90 0 4.8 10/02/85 03:45 37.6 37.60 0 5.5 10/02/85 09:45 35.2 35.20 0 5.0 10/02/85 15:45 33.2 33.20 0 5.0 10/02/85 21:45 32.4 32.40 0 6.0 DAILY AVG VALUES 34.60 0 5.4 10/03/85 03:45 30.8 30.80 0 4.0 10/03/85 09:45 29.2 29.20 0 3.0 10/03/85 15:45 28.8 28.80 0 3.5 10/03/85 21:45 28.0 28.00 0 5.0 DAILY AVG VALUES 29.20 0 3.9 10/04/85 03:45 27.2 27.20 0 4.5 10/04/85 09:45 26.4 26.40 0 3.0 10/04/85 15:45 26.0 26.00 0 3.5 10/04/85 21:45 25.2 25.20 0 5.0 DAILY AVG VALUES 26.20 0 4.0 D-BL/107 NORTEC FOR ALAS¥~ POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 6 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 10/05/85 03:45 25.2 25.20 0 3.5 10/05/85 09:45 23.6 23.60 0 2.5 10/05/85 15:45 23.6 23.60 0 3.0 10/05/85 21:45 23.2 23.20 0 4.5 DAILY AVG VALUES 23.90 0 3.4 10/06/85 03:45 22.4 22.40 0 4.5 10/06/85 09:45 22.4 22.40 0 4.5 10/06/85 15:45 22.0 22.00 0 5.0 10/06/85 21:45 21.6 21.60 0 5.0 DAILY AVG VALUES 22.10 0 4.8 10/07/85 03:45 21.2 21.20 0 5.0 10/07/85 09:45 21.2 21.20 0 4.5 10/07/85 15:45 20.8 20.80 0 5.0 10/07/85 21:45 20.8 20.80 0 5.5 DAILY AVG VALUES 21.00 0 5.0 10/08/85 03:45 24.8 24.80 0 4.5 10/08/85 09:45 23.6 23.60 0 5.0 10/08/85 15:45 23.2 23.20 0 6.0 10/08/85 21:45 23.2 23.20 0 6.5 DAILY AVG VALUES 23.70 0 5.5 10/09/85 03:45 24.0 24.00 0 5.5 10/09/85 09:45 23.2 23.20 0 4.5 10/09/85 15:45 22.4 22.40 0 4.5 10/09/85 21:45 21.6 21.60 0 5.5 DAILY AVG VALUES 22.80 0 5.0 10/10/85 03:45 21.6 21.60 0 5.0 10/10/85 09:45 21.2 21.20 0 5.0 10/10/85 15:45 20.8 20.80 0 5.0 10/10/85 21:45 20.4 20.40 0 5.5 DAILY AVG VALUES 21.00 0 5. 1 10/11/85 03:45 20.4 20.40 0 4.5 10/11/85 09:45 20.0 20.00 0 4.0 10/11/85 15:45 20.0 20.00 0 3.5 10/11/85 21:45 20.0 20.00 0 4.0 DAILY AVG VALUES 20.10 0 4.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 7 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 10/12/85 03:45 19.6 19.60 0 3.0 10/12/85 09:45 19.2 19.20 0 3.0 10/12/85 15:45 19.2 19.20 0 4.0 10/12/85 21:45 18.8 18.80 0 4.5 DAILY AVG VALUES 19.20 0 3.6 10/13/85 03:45 18.4 18.40 0 3.5 10/13/85 09:45 18.4 18.40 0 3.0 10/13/85 15:45 18.0 18.00 0 3.0 10/13/85 21:45 18.0 18.00 0 4.0 DAILY AVG VALUES 18.20 0 3.4 10/14/85 03:45 17.6 17.60 0 3.0 10/14/85 09:45 16.8 16.80 0 2.0 10/14/85 15:45 16.8 16.80 0 2.0 10/14/85 21:45 17.6 17.60 0 2.5 DAILY AVG VALUES 17.20 0 2.4 10/15/85 03:45 16.4 16.40 0 3.0 10/15/85 09:45 16.4 16.40 0 3.5 10/15/85 15:45 16.4 16.40 0 3.5 10/15/85 21:45 16.8 16.80 0 4.0 DAILY AVG VALUES 16.50 0 3.5 10/16/85 03:45 17.2 17.20 0 4.0 10/16/85 09:45 16.8 16.80 0 4.0 10/16/85 15:45 16.4 16.40 0 4.0 10/16/85 21:45 16.4 16.40 0 4.0 DAILY AVG VALUES 16.70 0 4.0 10/17/85 03:45 16.0 16.00 0 3.0 10/17/85 09:45 15.2 15.20 0 2.0 10/17/85 15:45 15.2 15.20 0 2.0 10/17/85 21:45 15.6 15.60 0 3.0 DAILY AVG VALUES 15.50 0 2.5 10/18/85 03:45 14.8 14.80 0 2.5 10/18/85 09:45 14.0 14.00 0 2.5 10/18/85 15:45 13.6 13.60 0 1.5 10/18/85 21:45 12.4 12.40 0 1.5 DAILY AVG VALUES 13.70 0 2.0 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 8 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=Gl*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 10/19/85 03:45 11.6 11.60 0 1.0 10/19/85 09:45 10.4 10.40 0 1.0 10/19/85 15:45 11.2 11.20 0 1.0 10/19/85 21:45 12.8 12.80 0 1.0 DAILY AVG VALUES 11.50 0 1.0 10/20/85 03:45 11.2 11.20 0 1.0 10/20/85 09:45 12.0 12.00 0 1.0 10/20/85 15:45 14.0 14.00 0 1.5 10/20/85 21:45 15.2 15.20 0 1.5 DAILY AVG VALUES 13.10 0 1.3 10/21/85 03:45 14.0 14.00 0 1.5 10/21/85 09:45 13.6 13.60 0 1.5 10/21/85 15:45 13.2 13.20 0 1.5 10/21/85 21:45 13.6 13.60 0 1.5 DAILY AVG VALUES 13.60 0 1.5 10/22/85 03:45 12.8 12.80 0 1.5 10/22/85 09:45 12.0 12.00 0 1.5 10/22/85 15:45 12.4 12.40 0 1.5 10/22/85 21:45 11.6 11.60 0 1.5 DAILY AVG VALUES 12.20 0 1.5 10/23/85 03:45 9.6 9.60 0 1.5 10/23/85 09:45 9.2 9.20 0 1.5 10/23/85 15:45 10.0 10.00 0 1.5 10/23/85 21:45 11.2 11.20 0 1.5 DAILY AVG VALUES 10.00 0 1.5 10/24/85 03:45 10.0 10.00 0 1.5 10/24/85 09:45 10.4 10.40 0 1.5 10/24/85 15:45 12.0 12.00 0 1.5 10/24/85 21:45 12.8 12.80 0 1.5 DAILY AVG VALUES 11.30 0 1.5 10/25/85 03:45 12.0 12.00 0 1.5 10/25/85 09:45 12.4 12.40 0 1.5 10/25/85 15:45 12.4 12.40 0 1.5 10/25/85 21:45 13.2 13.20 0 1.5 DAILY AVG VALUES 12.50 0 1.5 D-BL/107 NORTEC FOR ALASKA POWER AUTHORITY -BRADLEY LAKE HYDRO PROJECT Page 9 DATA REPORT FOR DATAPOD DP211SG-STAGE AND TEMP. RECORDER 01/20/86 Processed by Dryden & Larue DATA FILE : NFBRE START: 08/31/85 09:45 NORTH FORK BRADLEY RIVER STOP: 10/28/85 11:00 STAGE=DEPTH+GO DISCHG=G1*(DEPTH+GO) G2 GO=O G1=0 G2=0 DEPTH STAGE DISCHG TEMP DATE TIME INCHES IN. CFS DEG C 10/26/85 03:45 12.4 12.40 0 1.5 10/26/85 09:45 11.2 11.20 0 1.5 10/26/85 15:45 11.6 11.60 0 1.5 10/26/85 21:45 11.6 11.60 0 1.5 DAILY AVG VALUES 11.70 0 1.5 10/27/85 03:45 11.2 11.20 0 1.5 10/27/85 09:45 10.8 10.80 0 1.5 10/27/85 15:45 10.8 10.80 0 1.5 10/27/85 21:45 11.2 11.20 0 1.5 DAILY AVG VALUES 11.00 0 1.5 10/28/85 03:45 10.8 10.80 0 1.5 10/28/85 09:45 10.4 10.40 0 1.5 DAILY AVG VALUES 10.60 0 1.5 D-BL/107