Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
White Mountain Waste Heat Project Agreements Contracts & Budget 1992
Filename H:\RP\PROJBUDG.XLS Alaska Energy Authority Rural Programs Project Budget Community White Mountain Budget |waste Heat Revision No. 1 PJ CODE NAME PJ CODE [PROJECT NAME Preparer sJS Project Manager Steve Date 5/22/91 Source(s) of Funding Line Chart of Accounts WH LOC PROJECT TOTAL Dir Personal Services w/ Ben's Indirect Personal Services 71000 Personal Services SUBTOTAL 72000 Travel and Perdiem Eng & Prof Services Contracts Freight Project Cont '@11 Indirect Non-Personal Services [line 3 = line 1 + line 2) line 8 = 26% x line 1] CONAURWD = 73000 Other Services SUBTOTAL 74000 Project Materials and Equip. 75000 AEA Equipment 77000 Grants TOTAL Matrix Code Project AR Project CC 48 line 9 = sum of lines 5,6, Ly stock 2 t7445 be budget on reverse si Project LC ed Budget Approvals (initial and date) Manager/Rural Programs Director Agency Op. Director/ Rural Programs Executive Director cc: Gloria Manni Don Whelan Gary Smith & Preparer Pat Woodell Janet Hansen PT IES "Cee t PROJECT BUDGET WORKSHEET Project Information Community: White Mt Project Name: Waste Heat Project Project Number: AEA Project Manager: S. Stassel Date Prepared: 22-May-91 Date of Basis: 22-May-91 Prepared by: S. Stassel Date of Completion: Labor (Field Work) Name Rate {Subtotal | RSE Project Mgt, Construction 4,519 RCMWIII Construction 3,091 1,546 | | Local Labor $9,156] A Laborer |Construction Laborer |Operator Rate |Sub- |Total total 2} S500} 1000 RCMWIII RSE RCMWIII Project Mgt, Design Mob and Expediting [CAD Drafting PROJECT BUDGET WORKSHEET Project Information Material Description SE Misc me's Amount 35,000] 2.77, 245 SEA ATACHED | vee ofeek Freight Description rate $ A Pp DAG 250 pach gme NAC 15,000] + Barge fo Wkhte mt | | $15,000} F Contract [Description [Notes Amount | Hvy Equip |2 days at $500/Day 1,000] | | a Total $1,000] G Summary Personal Services (A+D) $12,572 Travel and Per Diem (C) $4,300 Material (E) $35,000 Freight (F) $15,000 Contract (B+G) $4,500 Ww Total _[- $71,372] i rove LD) he iT In + Aloat = 29/4, dep AO orsegh anisting cco lat manifold AvodO ADDINEM Heat exchigo, ad Avnet vale CC) Heat ax barge, Ano Avet vale wee Lf 1 Barn plas ( This 1s a BIG Assemphe ) (WV Nectic Pr ping distances cor2lQ nef <xceay FMA 2stimebdk (00 fort Ctrl pare) (DD fer dorign ard cottrwoton ww) FA Lab holy (© Cc pempa we fo 9rd ures bldg) ALE, | Hee Sef, Wate Moor Aw ld ns EA pm - Sle SheasseX Lochon Dist p.; P U la tian / 5O 495 Dieyp Coot Oat Gs Fenos Aree ( ace Sov bCeS Project Descrprr & A waste Wert recovery heating sy sm Ahh. bee ste lledk to provide heat fom p42 Port pla fo Phe Hnyh Scheel Gym Ad How School. AccoRdire fe TH Ema Waste Heat Report | Apprek srs hy eZ feck of Ache Pipe ts Reger key Te Tet exchanger WEL be locted tt Pre phe. TAR High Sched by” Tre 2p) re guibles A heat exchager nee) aK High Scheal tre -1w eS ee 2 . , lech ere re eet, m4, aur Beek heatig cols, ft desgn ardd tonstercban With dim fayce— Account lr«bor f Co vsteoctar : ° 66,372 = 7 Pha extn om te Dryer Coot | 4O62c0 Desir — ABA MATERIAL - feche Piping Ad Meyt Exchrgers 1 PrEX Steck. Misc. Lithagd | Copper pak stack pip) Circ perps pw Slyce/ 12) 40 be purchased Corteuctan — AE prey mgr Ad con skeucton ASs/s VAR IW Conponctron Loith loce( Uby, Schedukh- Glet ergs Pate Sstmna, Gl Ship hoch. Pipe Ni lita Thus Sapterber | ,/77/ $3 (Dhite Mr Loy £06 cov S85/%, = pes Ps “1as7a _ 376 Ses 4397 196 Chiper aay $363 Gwel'Sor) JE2.5° (AD Ska 372.5 T/PD Aa 30 | Stim *9 400 CoRG 4 | 990 ) ALloc 4 Td /Atioe 9306 Matéeezial 3 5 a0 —> ASssemes we vSe@ frtetee P per ak Hi ang valved at §220/shiclke And Ss | poirk Crvg coor) c he Fret /§ COO 5 flac. mitts do ore Aun Barge Contiack Rus00 | Lpom (Oorr > 6, rf, _OLMAA _ CA Lebo 43 sco 20 Hes Huy EQuiP 4 }oc0 : APPRox ith 1 coo Cort a onay 2 1270 4138 aa af piprag Ad Lent exchange iw AER stck a Cort ‘d hesiqn S VOC AP 5/24 by HSBUDGET.XLS PROJECT: WHITE MOUNTAIN WASTE HEAT PROJECT DATE: 2/4/92 DESCRIPTION: COST FOR SUMMER 1991 CONSTRUCTION ESTIMATOR: S.STASSEL MATERIAL COST LABOR HRS TOTAL TOT.COST WORK DESCRIPTION QUAN UNITS UNIT TOTAL UNITS TOTAL LAB.COST MAT.& LAB POWER PLANT TO HIGH SCHOOL GYM ARCTIC PIPE Trenching, Labor 400 Feet $0 $0 0.03 12.0 $512 $512 FA Laborer Backhoe & Operator 1 Days $500 $500 10.00 10.0 $427 $927 FA Operator * Place & Weld Pipe 10 Lengths $220.00 $2,200 4.28 42.8 $1,826 $4,026 FA Laborer * Place & Weld Pipe 10 Lengths $220.00 $2,200 4.28 42.8 $1,826 $4,026 RSE + RCMW * Ells-Ftg. & Shell 10 Each $65.00 $650 0.00 0.0 $0 $650 FA Laborer * Coupling-Ftg. & Shell 20 Each $45.00 $900 0.00 0.0 $0 $900 FA Laborer Joint Work 15 Each $0.00 $0 0.67 10.0 $427 $427 FA Laborer Joint Work 15 Each $0.00 $0 0.67 10.0 $427 $427 RSE + RCMW E-Joint 0 Each $250.00 $0 8,00 0.0 $0 $0 RCMW Backfill Trench, Labor 400 Feet $0 $0 0.03 12.0 $512 $512 FA Laborer Backhoe & Operator 1 Day $500 $500 10.00 10.0 $427 $927 FA Operator Bedding Mtl 22 yds $2 $44 0.00 0.0 $0 $44 FA Operator Page 1 HIGH SCHOOL GYM CONNECTION 1-1/2" bronze gate valves (swt) 1-1/2" D.E Unions Hoffman #79 air vents *250 MBH heat exchanger 2-1/2" x 1-1/2" reducers Grundfos UP43-75F pump Pressure relief valves Aquastats 1-1/2" 3-way, 2 pos valve 2" gate valve (swt) Weksler dial thermometers 1-1/2" balance cock 1-1/2" Copper pipe, 20' stick 30 gallon expansion tank 1" steel pipe, 20' stick Miscellaneuos Fittings Connect Piping Connect Piping 6 Each 2 Each 2 Each 1 Each 2 Each 1 Each 2 Each 2 Each 1 Each 1 Each 4 Each 1 Each 3 Each 1 Each 1 Each 1 Lot 1 Each 1 Each $50 $50 $65 $4,250 $5 $150 $75 $50 $1,000 $50 $75 $75 $200 $600 $50 $500 $0 $0 HSBUDGET.XLS $300 0.50 3.0 $100 1.00 2.0 $130 0.25 0.5 $4,250 10.00 10.0 $10 0.25 0.5 $150 1.00 1.0 $150 0.25 0.5 $100 4.00 8.0 $1,000 2.00 2.0 $50 0.50 0.5 $300 0.25 1.0 $75 0.50 0.5 $600 0.00 0.0 $600 8.00 8.0 $50 0.00 0.0 $500 0.00 0.0 $0 10.00 10.0 $0. 10.00 10.0 8365.0 57.5] Page 2 $128 $85 $21 $427 $21 $21 $341 $85 $21 $21 $0 $341 $0 $0 $427 $427 $428 $185 $151 $4,677 $31 $193 $171 $441 $1,085 $71 $343 $96 $600 $941 $50 $500 $427 FALaborer $427 RSE + RCMW HIGH SCHOOL GYM TO HIGH SCHOOL Trenching, Labor Backhoe & Operator * Place & Weld Pipe * Place & Weld Pipe * Ells-Ftg. & Shell * T-Ftg & Shell * Coupling-Ftg. & Shell Joint Work Joint Work E-Joint Backfill Trench, Labor Backhoe & Operator Bedding Mtl HIGH SCHOOL CONNECTION 52 MBH heating coils 1-1/4" 3 way, 2 pos valve 1-1/4" gate valves (swt) 1-1/4" balance cocks 1-1/4" Copper pipe, 20! stick 1-1/4" D.E. Unions 1-1/2" gate valves Grundfos UP43-75F pump 2-1/2" x 1-1/2" reducer 2-1/2" x 1-1/4" reducer Hoffman #79 air vents Weksler dial thermometers Misc. Fittings and piping con's 150 Feet 1 Days 4 Lengths 4 Lengths 5 Each 1 Each 8 Each 7 Each 7 Each 0 Each 150 Feet 1 Day 10 yds 2 Each 2 Each 3 Each 2 Each 4 Each 2 Each 2 Each 1 Each 1 Each 1 Each 2 Each 4 Each 1 Lot $0 $500 $220.00 $220.00 $65.00 $100.00 $45.00 $0.00 $0.00 $250.00 $0 $500 $2 $885.00 $1,000.00 $35.00 $250.00 $200.00 $50.00 $50.00 $150.00 $5.00 $5.00 $60.00 $75.00 $500.00 HSBUDGET.XLS $0 $500 $880 $880 $325 $100 $360 $0 $0 $0 $0 $500 $20 $1,770 $2,000 $105 $500 $800 $100 $100 $150 $5 $5 $120 $300 $500 6455.0 0.03 4.5 10.00 10.0 4.28 17.1 4.28 17.1 0.00 0.0 0.00 0.0 0.00 0.0 0.67 4.7 0.67 4.7 8.00 0.0 0.03 4.5 10.00 10.0 0.00 0.0 8.00 16.0 2.00 4.0 0.50 1.5 0.50 1.0 0.00 0.0 1.00 2.0 0.50 1.0 1.00 1.0 0.25 03 0.25 0.3 0.25 0.5 0.50 2.0 20.50 20.5 Page 3 $192 $427 $730 $730 $0 $0 $0 $199 $199 $0 $192 $427 $683 $171 $64 $43 $0 $85 $43 $43 $11 $11 $21 $85 $875 $192 $927 $1,610 $1,610 $325 $100 $360 $199 $199 $192 $927 $20 $2,453 $2,171 $169 $543 $800 $185 $143 $193 $16 $16 $141 $385 $1,375 FA Laborer FA Operator FA Laborer RSE + RCMW FA Laborer FA Laborer FA Laborer FA Laborer RSE + RCMW RCMW FA Laborer FA Operator FA Operator RCMW RCMW RCMW RCMW RCMW RCMW RCMW RCMW RCMW RCMW RCMW RCMW RCMW HSBUDGET.XLS POWER PLANT CONNECTION (both Gym and School) Hoffman #69 air vents 2 Each $60 $120 0.25 0.5 $21 $141 2-1/2" Butterfly Valves 7 Each $85.00 $595 1.00 7.0 $299 $894 *350 MBH heat exchanger 1 Each $4,500.00 $4,500 10.00 10.0 $427 $4,927 2-1/2" Amot valve 1 Each $450.00 $450 4.00 4.0 $171 $621 Pressure Relief Valves 2 Each $75.00 $150 0.25 0.5 $21 $171 Weksler Dial thermometers 4 Each $75.00 $300 0.50 2.0 $85 $385 Honeywell Aquastats 3 Each $125.00 $375 4.00 12.0 $512 $887 2-1/2" Steel Pipe, 20' stick 3 Each $50.00 $150 0.00 0.0 $0 $150 Miscellaneous mtls 1 lot $250.00 $250 0.00 0.0 $0 $250 Connect Piping 1 Job $0.00 $0 17.00 17.0 $725 $725 FALaborer 1 Job $0.00 $0 17.00 17.0 $725 $725 RSE + RCMW 6890.0 MISCELLANEOUS ‘60/40 Propylene Glycol 400 Gal. $5.50 $2,200 0.03 12.0 $512 $2,712 RSE + RCMW Supports, Bolts, etc 1 Each $500.00 $500 0.00 0.0 $0 $500 N/A Check & Adjust Controls 1 Each $0.00 $0 8.00 8.0 $341 $341 RSE Mob & Demob 1 Job $0.00 $0 30.00 30.0 $1,280 $1,280 RSE + RCMW SUBTOTAL: ARCTIC PIPE | 34,969 450} $19,184 $54,153 Labor rate used: $42.66/hr * - MATERIAL CURRENTLY OWNED BY AEA, VALUE= [ $17,245 NET MATERIAL REQUIRED= [ $17,724 Page 4 WHITE MOUNTAIN AGREEMENT THIS AGREEMENT, entered into this a day of 1988, between the Bering Straits Regiona Housing Authority (BSRHA), the City of White Mountain (City), and the Alaska Power Authority (Power Authority) outlines the responsibilities of the parties and the proce- dures to be followed in connection with the distribution line extension from the existing distribution system to the new homes associated with the Department of Housing and Urban Development (HUD) project AKO6B008030. (The distribution line extension is hereinafter referred to as the "Project.") This Agreement represents the entire agreement between the parties and may only be modified by the mutual consent of all parties to this Agreement in writing. Article A. ALASKA POWER AUTHORITY COVENANTS The Power Authority will: 1. Perform a detailed review of the existing site conditions, coordinate all necessary engineering design for the Project, and coordi- nate upgrade of the existing City electrical system and telephone utility with the Project. 2. Provide all necessary supervision for the construction of the Project either with Power Authority staff or with contractors or consul- tants under contract to the Power Authority. 3. Make every reasonable effort to utilize locally available labor for the Project to the extent this is judged by the Power Authori- ty to be beneficial to the Project. 4. Assist the City in resolving operational difficulties with the Project, if needed, for one calendar year after completion. Such difficulties do not include matters normally considered to be routine maintenance. 5. Procure materials and services as needed for the Project. 6. Subject to appropriation and availability of funding, provide funds for the Project, not to exceed $10,000. These funds will only be used to pay for Power Authority direct and indirect personal services costs, for other Power Authority non-personal services costs that are normally distributed on the basis of direct labor hours in accordance with standard Power Authority accounting procedures, for contractors or consultants under contract to the Power Authority in accordance with Article A, Paragraph 2 above, and for Power Authority staff travel and per diem to the extent funding is not available in accordance with Article B, Paragraph 4 to cover such travel costs. 7. Accept payments from the BSRHA as described in Article B, Paragraph 4 and Paragraph 5 of this Agreement, and account separately 3740/DD36(1) White Mountain -eement Page 2 of 6 for these funds within the Power Authority's Rural Construction Assis- tance account, subject to availability of appropriation of said account. 8. Reimburse the City for materials and supplies, as described in Article C, Paragraph 7 of this Agreement, at a rate equal to the cost of said materials and supplies to the City plus five percent for adminis- tration and handling costs. Reimbursement will be made on undisputed invoices within 45 days after receipt. Article B. BERING STRAITS REGIONAL HOUSING AUTHORITY COVENANTS The BSRHA will: a Ensure all necessary access and rights-of-way, for the Power Authority and its contractors or consultants on the Project, to property over which the BSRHA has site control. 2. Provide copies of all available surveys and plats for any area affected by the Project. 3. Upon request, provide Power Authority personnel access to and copies of any information or document related to any phase of the Project over the life of the Project. 4. Out of HUD project AK06B008030 funds received for payment to the City for electrification, provide payment directly to the Power Authority for Project expenditures in an amount not to exceed $100,000. These funds will be used for materials, supplies, equipment rental, contractual services, local labor, and Power Authority staff travel and per diem. The BSRHA will not reimburse the Power Authority for direct or indirect staff salary costs or for legal expenses in connection with the Project not otherwise indemnified under Article D, Paragraph 1 of this Agreement. 5. Within 30 days after HUD approval and notice to proceed with construction of project AK06B008030, or within 30 days after execution of this Agreement, whichever occurs later, submit to the Power Authority an advance payment of not less than $50,000 to provide engineering, mobilization, and purchase of materials. 6. Submit payment to the Power Authority for authorized expenses incurred or for 30-day advance payments to cover anticipated expenses and provide reimbursement for undisputed invoices no later than 30 days after receipt of the invoice. Article C. CITY OF WHITE MOUNTAIN COVENANTS The City will: 1. Ensure access and rights-of-way, for the Power Authority and its contractors or consultants on the Project, over and to any property necessary for the construction of the Project. 3740/DD36(2) White Mountain reement Page 3 of 6 2. Upon request, provide Power Authority personnel access to and copies of any information or document related to any phase of the Project over the life of the Project. 3. Accept ownership of the Project as completed and accept full responsibility for its operation and maintenance, in writing, within fourteen calendar days after receipt of a notice of Project completion from the Power Authority. 4. Operate and maintain the system in strict compliance with NEC and NESC rules and with standard utility project management and opera- tion and maintenance practices for the life of the Project. 5. Authorize the BSRHA to make payments on behalf of the City to the Power Authority for expenditures related to the Project in accor- dance with this Agreement. 6. Provide on-site manpower assistance to the Power Authority or its contractors in performance of this Agreement upon receipt of a Power Authority work order signed by the Power Authority project manager and an authorized representative of the City, describing the assistance to be provided, and setting forth the rates by which the City will be reimbursed for said assistance. 7. At the request of and as specified by the Power Authority, provide materials and supplies for construction of the Project and submit invoices for said materials and supplies to the Power Authority for payment in accordance with Article A, Paragraph 8 of this Agreement. Article D. MUTUAL COVENANTS The Power Authority, the BSRHA, and the City agree to the follow- ing: 1. Indemnification. (a) The Power Authority, the BSRHA, and the City shall indemnify, save harmless and defend the other parties to this Agreement, their officers, agents, servants, and employees from all liability, including costs and expenses, for all actions or claims resulting from injuries or damages sustained by any person or property arising directly or indirectly as a result of any error, omission or negligent act of the indemnifying party, their officers, agents, ser- vants, or employees or anyone directly or indirectly employed by them in the performance of this Agreement. The labor and manpower assistance provided by the City under Article C, Paragraph 6 of this Agreement shall be considered the officers, agents, servants, or employees of the City for purposes of construing these indemnification provisions. (b) All actions or claims, including costs and expenses, resulting from injuries or damages sustained by any person or property arising directly or indirectly from the BSRHA's or the City's performance of this Agreement which are caused by the joint negligence of the Power Authority and the BSRHA or the City shall be apportioned on a compara- tive fault basis. Any such joint negligence on the part of the Power 3740/DD36(3) White Mountain -eement Page 4 of 6 Authority must be a direct result of active involvement by the Power Authority. 2. Assignment of Authority. The BSRHA and the City assign to the Power Authority, full authority over all decisions in connection with initial study, design, construction, and start-up of the Project and over all choices of scheduling, manpower, methods, materials, proce- dures, etc. for the Project, except as required by the design needs of HUD project AK06B008030 to be served by the Project and as may be dictated by construction schedules and normal cooperation between contractors working within rights-of-way on the water, sewer, road, and electrification phases of HUD project AK06B008030. 3. Declaration of Cooperation. The parties to this Agreement agree to make every reasonable effort to promote local involvement in the Project through local input into design review, through the utiliza- tion of local labor, and through local involvement in the procurement of materials. The parties to this Agreement agree to make every reasonable effort to promote timely completion of the Project through responsive- ness and cooperation by December 31, 1989. At the request of any party to this Agreement, Project meetings with the other parties will be held within seven calendar days after the receipt of such request, in writ- ing, by the other parties. All such meetings will be held in Anchorage unless a different location is mutually agreed upon. 5. Other Parties Not Being Agents of Each Other. It jis agreed that the Power Authority, its officers, agents, servants and employees shall act in an independent capacity and not as agents of the BSRHA or the City in performance of this Agreement. It is further agreed that the BSRHA and the City, their officers, agents, servants and employees shall act in an independent capacity and not as agents of the Power Authority in the performance of this Agreement. 6. Disputes. This Agreement shall be governed by the laws of the State of Alaska. Any lawsuit involving this Agreement shall be heard by the Superior Court, Third Judicial District at Anchorage. All expenses in connection with disputes including all legal expenses shall be paid by the party incurring these expenses. 7. Rights of Other Parties. It is the intent of the parties that this Agreement confer no rights to any third parties. 8. Binding Effect. This Agreement and all of its terms, cove- nants and conditions shall extend to and be binding upon the respective heirs, executors, administrators, grantees, successors and assigns of the parties to this Agreement. 3740/DD36(4) White Mountain ‘eement Page 5 of 6 THIS AGREEMENT has been reviewed, agreed to, and executed by the following parties: ,. esche Date ve Director STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) Ww The foregoing Agreement was acknowledged before me this 3) day of . » 1988 by Robert E. LeResche the Executive Director of the Alaska Power Authority, an Alaskan Corporation, on behalf of the corpo- ration. i. Notary PubfAc, State of Alaska My commisston expires: 3/9/42. Approved: 10 -¢-88 sistant’ Attoyngy General Date 3740/DD36(5) White Mountain *eement Page 6 of 6 BERING STRAITS REGIONAL HOUSING AUTHORITY Qanecl . Ver (0-13-88 aniel H. Harrelson Date Executive Director STATE OF ALASKA ss. THIRD JUDICIAL DISTRICT ) The foregoing Agreement was acknowledged before me this 3 day of Ccpten) " rrefor ,» 1988, by Daniel H. Harrelson, Executive Director for the Bering Straits Regional Housing Authority, on behalf of the Bering Straits Regional Housing Authority. ‘ary Pu Tc, State of Commission expires: 729/90 CITY OF WHITE MOUNTAIN My CommissionExpires July 29,196) ayo, Date STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing Agreement ee acknowled oe before _me this (FE -tay of , 1988, by Gee VecG(Mayor of the City of ite Mountain, on behalf of t ite Mountain. aska Commj s5ion ©) ex tary Pa iP Per USPS ASM "v, 3740/DD36(6) eiyer UTILITY POLE AGREEMENT Mukluk Telephone Co., Inc. (hereinafter Mukluk) 20 AC eee poe to purchase from the City of White Mountain or oe “the White Mountain city council, 40 class 5 thirty foot poles, belonging to the City of White Mountain and presently located at Nome, Alaska. These poles shall be purchased by Mukluk at the actual invoice cost plus amounts actually paid for freight. Possession of the poles shall be delivered at their present location at Nome. The present design criteria for the construction of telecommunication facilities at White Mountain by Mukluk provides for the utilization of 35 foot class 4 poles. The poles actually to be used by Mukluk at White Mountain shall be the 35 foot class 4 poles. Mukluk hereby agrees to provide pole space on these poles for primary and secondary electrical distribution lines with said lines to be placed and maintained by the City of White Mountain. Mukluk will impose no charge or cost to the City of White Mountain for this pole space. : The pole line shall not be removed for the life of the poles and the pole line shall be maintained by Mukluk. —_— pateo: June /2, /7E&l MUKLUK TELEPHONE COMPANY, INC. WHITE MOUNTAIN Ore By ayer ar henfgAter Mayor STATE OF ALASKA SECOND JUDICIAL DISTRICT THIS IS TO CERTIFY that on this /<=day of JUNE, 1981, before me a Notry Public or Postmaster in and for the State of Alaska, personally appeared ROBERT BLODGETT and KARL ASHENFELTER each to me personally known and known to be the individual described in and who executed the foregoing instrument and that each acknowledged to me that he signed and sealed the same freely and voluntarily for the uses and purposes therein mentioned. SUBSCRIBED AND SWORN to before me the day and year last above written. ae 2 OTARY PUBLIC FOR ALASKA ly commission expires: