HomeMy WebLinkAboutRural Bulk Fuel Storage 1998CHATE WP LING KI) 7 rotons, covemno DEPARTMENT OF COMMUNITY AND 333 WEST FOURTHAVE., SUITE 220 REGIONAL AFFAIRS ANCHORAGE, ALASKA 99501-2341 PHONE: (907) 269-4500 DIRECTOR'S FAX: (907) 269-4645 DIVISION OF ENERGY ENGINEERING FAX: (907) 269-4685 March 20, 1998 Mr. Dennis McCrohan Deputy Director ee oad Project Development & Operations a _ Alaska Energy Authority Cc. KO 480 W. Tudor DRS 9 VY Anchorage AK 99503-6690 aydotrn Th~ Subject: Rural Bulk Fuel Storage Dear Mr. McCrohan: Provided below is information prepared by the Division of Energy on bulk fuel storage funding and project selection that may be of interest to you in connection with our meeting on March 19, 1998. The attachments have been updated to include the tank farms added to our data base during the past year. In 1997, the Division of Energy developed a six year plan for comprehensive upgtade and consolidation of bulk fuel storage facilities in rural Alaska. The plan has been accepted by the Environmental Protection Agency as the basis for selecting tank farm consolidation projects to be funded in whole or in part with EPA grants. The Division also manages the construction of tank farm repair and upgrade projects where other funds are available, including but not limited to: . ICDBG grants Indian Community Development Block Grants awarded to rural communities through the U.S. Department of Housing and Urban Development. . CDBG grants Community Development Block Grants funded by the federal government but awarded to rural communities by the Alaska Department of Community and Regional Affairs. . State funds State funds appropriated directly to the Division or to another State agency that contracts with the Division to build the projects. For example, State funds were appropriated this year to the Dept. of Education, which selected the rural school tank farm projects it Rural Bulk Fuel Storays March 20, 1998 considers highest priority and transferred the funding and construction responsibility to the Division. The core of the Division’s six year plan for EPA consolidation projects is the selection of communities based on the relative condition of their existing tank farms and several other selection criteria. This selection process is summarized below: Development of Rural Tank Farm Data Base In 1996, the Division initiated a program to continually update our data base on rural tank farm conditions. Engineering contractors are sent to an average of 50 villages each summer to examine each tank farm and to record its condition and major characteristics. Tank farms in 81 rural communities have now been examined over the last two years and approximately 80 more are scheduled for site visits in 1998. When tank farms in all the rural villages have been examined, we plan to revisit each community on a three-year schedule to provide regular updates on tank farm conditions. Attachment 1 presents a summary of information the Division has acquired in 79 of the 81 communities where site visits have been conducted over the last two years. For each tank farm, deficiency points are assigned in seven categories with total points shown in the column on the far right. The key that defines the meaning of these points is included as Attachment 2. For each of the 79 communities in Attachment 1, an index labeled “weighted average points per tank farm” is calculated. This differs from a simple average in that the weight given to each tank farm is proportional to its storage capacity. For example, tank farm #2 in the community of Angoon accounts for 95% of the total storage capacity shown for the community, and its deficiency point total is zero. This explains why the weighted average for the community is 0.9 even though the simple average would be 10.0. Before calculating the “weighted average points per tank farm,” we removed certain tank farms from the Attachment 1 listing and therefore from the calculation. What we removed specifically were: ile Tank farms owned by Alaska Village Electric Cooperative (AVEC). AVEC has determined that, although exceptions may occur, in general it does not wish to participate in a consolidated facility. Rural Bulk Fuel Store _ March 20, 1998 2. Tank farms that, to the best of our knowledge, are privately owned. There were certain privately owned tank farms that we did not remove, however, including the following: a. Tank farms of investor-owned utilities. To determine if the use of public funds is appropriate, a key test is whether the facilities to be improved serve a public purpose. We conclude that utilities that are privately owned have an important public purpose component that distinguishes them from most other private economic activity. b. Tank farms owned by Native village corporations organized under the Alaska Native Claims Settlement Act. Although these corporations are not government entities, their shareholders typically consist of most or all of the residents in a Native community. This gives them a public character that is again distinct from most other private corporations. All of the tank farms that were removed from Attachment 1 and its calculations are listed in Attachment 3. Two of the 81 communities (Gustavus and Tenakee Springs) were removed because all of the bulk fuel storage in these communities is privately owned. Each of the 79 communities was then ranked according to its “weighted average points per tank farm.” Those with the highest scores are considered to have the worst overall tank farm conditions, while those with the lowest scores are in the best condition. This ranking is shown in Attachment 4. While useful, our deficiency ranking is not enough by itself to identify the next set of consolidation projects for two reasons: ae As discussed below, there are other factors besides tank farm condition that are properly considered in allocating limited funds. 2) While these numbers suggest precision, they are appropriate for use only as a general index of average conditions. Selection of Communities The initial pool for project selection consists of those communities in the upper portion of the list. Other decision criteria are then applied by the Division depending on the specific communities in the candidate pool. Examples include: Rural Bulk Fuel Store _ March 20, 1998 . Consolidation opportunity. . Community size. . Availability of other funding. . Average income level. . Administrative and maintenance capability shown on earlier projects. . Any federal tax delinquency of tank farm owner(s). . Community contribution and commitment evidenced in part by prompt action on consolidation agreements. . Past experience working in the community. ° Unusual conditions or costs. The three communities most recently selected for upgrade and consolidation projects by the Division as a result of this process are Beaver, Chignik Lake, and Manokotak, which were ranked #2, #5, and #8 respectively on the overall deficiency rankings at the time the selections were made. Please let me know if you have any comments on this material or any suggestions as to how our rural bulk fuel storage program could be strengthened. Sincerely, ged Percy Frisby Director Attachments as stated ATTACHMENT 1 Alakanuk Tank Farm ID Owner evaluation date 2 Alakanuk Native Corporation 10/1/97 3 State of Alaska Village Safe Water 10/1/97 4 Lower Yukon School District 10/1/97 5 City of Alakanuk 10/1/97 total capacity Alatna Tank Farm ID Owner evaluation date 1 Alaska Power and Light 9/9/97 total capacity Aleknagik Tank Farm ID Owner evaluation date 2 City of Aleknagik 10/20/96 3 Mission Lodge 10/20/96 3/11/98 BULK FUEL LATEST ASSESSMENTS REPORT total capacity capacity 124,000 40,000 132,000 4,000 Site 10 10 Site Site Diking 30 30 Diking Diking 30 Found 10 10 Found Found 15 Tanks Piping Elec. Safety Total 10 60 0 30 150 0 10 0 10 20 0 10 0 10 20 10 10 0 20 90 total points 280 weighted average points/tank farm 74.67 Tanks Piping Elec. Safety Total 0 10 0 10 20 total points 20 weighted average points/tank farm 20.00 Tanks Piping Elec. Safety Total 10 0 10 30 95 0 0 0 0 5 total points 100 weighted average points/tank farm 37.76 Page 1 of 26 Allakaket Tank Farm ID Owner evaluation date 1 City of Allakaket 9/8/97 2 Allakatna Co-op Store 9/8/97 3 Yukon-Koyukuk School District 9/8/97 4 Yukon-Koyukuk School District 9/8/97 5 City of Allakaket (Brice) 9/8/97 total capacity Angoon Tank Farm ID Owner evaluation date 2 Tlingit-Haida Regional Electric Association 8/29/96 3 City of Angoon - Public Water 8/29/96 total capacity Aniak Tank Farm ID Owner evaluation date 1 Department of Transportation & Public Facil 11/6/97 2 Kuspuk School District 11/6/97 3 Aniak Power & Light 11/6/97 6 Bush-Tell 11/6/97 a Alaska Commercial Co. 11/6/97 8 City Maintenance Shop 11/6/97 total capacity 3/11/98 capacity 12,000 9,252 9,500 1,500 10,000 42,252 capacity 62,468 3,000 65,468 capacity 3,800 142,100 195,000 6,000 15,200 1,500 363,600 Site 10 10 10 10 Site Site oooocso 10 Diking 10 20 30 30 10 Diking Diking 30 20 30 30 Found ooooco Found Found 10 oo 10 Tanks _—_— Piping Elec. Safety Total 10 10 0 20 60 0 10 10 20 70 10 0 0 10 60 10 10 0 20 80 10 5 0 10 35 total points 305 weighted average points/tank farm 56.98 Tanks Piping Elec. Safety Total 0 0 0 0 0 0 10 0 10 20 total points 20 weighted average points/tank farm 0.92 Tanks Piping Elec. Safety Total 0 20 10 30 100 10 20 0 20 75 0 0 0 0 0 0 30 10 20 60 10 0 0 0 40 5 10 0 10 75 total points 350 weighted average points/tank farm 33.33 Page 2 of 26 Beaver Tank Farm ID Owner 1 Yukon Flats School District 2 Beaver Tribal Council 3 Beaver Tribal Council Bettles Tank Farm ID Owner 1 Alaska Power & Telephone 3 Bettles Lodge 5 Evansville Tribal Council Brevig Mission Tank Farm ID Owner 1 Bering Straits School District 2 Bering Straits School District 3 City of Brevig Mission 4 City of Brevig Mission 5 Brevig Mission Church 6 Alaska Army National Guard 8 City of Brevig Mission 3/11/98 evaluation date 7124/96 7124196 7124196 total capacity evaluation date 9/9/97 9/9/97 9/9/97 total capacity evaluation date 9/20/96 9/20/96 9/20/96 9/20/96 9/20/96 9/20/96 9/20/96 total capacity capacity 57,000 32,000 2,000 91,000 capacity 85,000 10,000 5,000 100,000 capacity 71,000 30,500 25,500 46,250 8,000 4,750 8,000 194,000 Site 10 Site ° Site 10 10 10 10 Diking 30 20 30 Diking Diking 10 20 10 20 20 10 Found 15 Found Found 20 10 10 10 Tanks _—— Piping Elec. Safety Total 10 50 0 20 135 10 30 0 20 85 0 20 0 20 75 total points 295 weighted average points/tank farm 116.10 Tanks _ Piping Elec. Safety Total 10 30 0 20 65 0 20 10 20 50 0 5 0 0 5 total points 120 weighted average points/tank farm 60.50 Tanks Piping Elec. Safety Total 10 10 10 20 70 10 10 10 20 80 10 0 0 20 70 10 20 0 20 80 10 20 0 20 80 10 10 0 10 40 10 20 0 10 60 total points 480 weighted average points/tank farm 73.22 Page 3 of 26 927 J0 y oBeg 86/LL/E LObd we) yueysjulod eBesone payybiom 0zz sjulod 1}0) Oor'es Ayoedeo |2}0} OL oz 0 OL OL 0 oe 0 000'S 96/6/8 muBIYD Jo aBey}!\ OANeN 9 08 02 0 oL 0 OL o€ OL 00¢'s 96/6/8 PUJSIG [OOYDS B/NSUJUed *B OYe7 € OL 0z OL OL oe 0 0 0 000'er 96/6/8 Wounog abel, Aeg yuB1yD z reyol Keyes = 9015) Buidig = syue, punoy Bbuniqg oes Ayoedeo ayep uojenjeno JOUMO Qi wey yuey Aeg y1uB1YyD v6'LZ1 —- ue yuRY/Sjulod eBesene payyBiem SIL sjulod 1e}0} Ovz'9ce Ayoedeo |2}0} 0 0 0 0 0 0 0 0 000'02 L6/9 1/6 yeAaYD Jo AyD 6 OL 0 0 0 0 0 OL 0 009'2 L6/9 1/6 HOUND jeuoNIpes| YeABYD 8 Oz oe OL 02 OL OL oe OL 000'9¢ L6/9L/6 (yoeaq) Auedwod yeneyo 74 os OL 0 OL 0 0 oe 0 00s'z L6/9L/6 Pueng jeuoyeNn Ay eysely 9 o1z oc OL o¢ or OL 0z 0 Ovz'oLL L6/91/6 210}g Auedwog yeaayo v SSL oz 0 OL OL S oe 02 009'61 L6/9L/6 WEABYD JO AD z S6 02 0 0z OL SI oe 0 000'01 L6/91/6 HOUND jeuoNipes] YeASYD OL GL or 0 Ov 0 S 0z 0 ooe'6Lt L6/9L/6 PUISIG |OOYDS jnjWeUNysey L 1e}0L, Ayoyes “99/3 Buidig syuey puno4 6bupig es Ayoedeo eyep uonenjead JOUMO GI wey yuey yeasyo S696 uwuey yueysjuiod eBeJane payybiem Sbb sjulod je}0} oee'esz Ayoedeo 230) 09 OL 0 oe 0 OL OL 0 0 26/82/01 Wed JUBWES | JOJEM\ SHd 9 0 0 0 0 0 0 0 0 o0e'y 26/82/01 Bulpjing pueng jeuonen S OZ oe 0 os 0 OL 0z OL 008'Ze 26/8Z/01 JOoYyIS WIMYOXSNY JEMO7 v 06 oe 0 0z 0 0z 0z 0 ocr’ le 26/8Z/01 lOOY9S WIMYOSN> JOMO7] £ Oz oe 0 os 0 OL oe 0 008's8 26/82/01 “Ou BINWIUEJSYD z ss oz 0 0 0 S oe 0 00S'by 26/8Z/01 HEUIOJOYD JO AND L 1eyOL Ayayes ‘09/3 Buidig syuel punoy Buia ous Ayoedeo eyep uojenjerd JOUMO GI) wey yuey yeusojoy Chignik Lagoon Tank Farm ID Owner 1 Lake & Peninsula School District 2 Native Village of Chignik Lagoon 5 Native Village of Chignik Lagoon 5 Native Village of Chignik Lagoon 6 ATT/Alascom Chignik Lake Tank Farm ID Owner 1 Chignik Lake Village Council 2 Lake & Peninsula School District Clark's Point Tank Farm ID Owner 3 City of Clarks Point 4 City of Clark's Point 5 City of Clarks Point 6 Southwest Region School District 7 City of Clarks Point 3/11/98 evaluation date 8/8/96 8/8/96 8/8/96 8/8/96 8/8/96 total capacity evaluation date 8/7/96 8/7/96 total capacity evaluation date 10/21/96 10/21/96 10/21/96 10/21/96 10/21/96 total capacity capacity 30,000 75,000 1,500 2,000 2,500 111,000 capacity 42,300 45,400 87,700 capacity 1,000 22,600 32,600 9,900 10,200 76,300 Site 10 10 10 Site 0 10 Site 10 10 10 Diking 30 30 30 30 Diking 20 20 Diking 30 20 20 10 20 Found 10 10 10 10 Found Found cooam Tanks Piping Elec. Safety Total 10 10 0 10 35 30 20 10 30 140 30 20 0 20 120 30 20 0 10 100 0 20 10 20 100 total points 495 weighted average points/tank farm 109.73 Tanks _—— Piping Elec. Safety Total 30 20 10 20 100 10 20 10 20 95 total points 195 weighted average points/tank farm 97.41 Tanks Piping Elec. Safety Total 0 10 0 10 65 0 10 10 10 65 30 10 10 10 90 0 15 0 10 35 30 20 0 10 80 total points 335 weighted average points/tank farm 73.79 Page 5 of 26 Coffman Cove Tank Farm ID Owner 2 Alaska Power & Telephone Cold Bay Tank Farm ID Owner 10 U.S. Fish & Wildlife Service 11 ADOT 12 U.S. Fish & Wildlife Service 14 FAA-Flight Service Station 15 Old Fire Station/ADOT/PF 16 City of Cold Bay 17 USAF Long Range Radar Site 18 AT&T Alascom Site 2 G & K Electric Inc. 3 ADOT Warm Storage Building 4 ADOT Fueling Station 5 FAA Shop & Fuel Station 6 ADOT Shop Building a Aleutians East Borough School District 8 ADOT Sand Point Storage Building 9 City of Cold Bay 3/11/98 evaluation date 7/24/96 total capacity evaluation date 8/7/96 8/7/96 8/7/96 8/7/96 8/7/96 8/7/96 8/7/96 8/7/96 8/6/96 8/6/96 8/6/96 8/6/96 8/7/96 8/7/96 8/7/96 8/7/96 total capacity capacity 6,300 6,300 capacity 24,000 3,230 1,000 1,500 909 2,200 4,800 500 13,400 5,360 7,800 2,000 4,290 2,790 2,230 1,100 77,109 Site Site ooooo = o oooooocococje Diking Diking Found Found 10 10 10 10 10 10 10 15 10 15 10 10 Tanks _—— Piping Elec. Safety Total 0 10 0 10 20 total points 20 weighted average points/tank farm 20.00 Tanks Piping Elec. Safety Total 0 20 0 10 70 0 0 0 10 20 0 10 oO 10 30 0 0 0 0 0 10 10 0 20 80 0 0 10 30 60 0 0 0 10 20 0 0 0 0 0 0 10 0 10 30 10 5 0 10 65 10 5 10 20 60 0 0 0 0 0 10 0 0 10 60 10 5 0 10 60 10 10 0 10 70 0 10 0 10 30 total points 655 weighted average points/tank farm 50.68 Page 6 of 26 Craig Tank Farm ID Owner 3 Alaska Power & Telephone 4 City of Craig 5 AT&T/Alascom Egegik Tank Farm ID Owner 3 Lake & Peninsula Borough School District 5 City of Egegik Ekwok Tank Farm ID Owner 1 Southwest Region School District 2 Ekwok Natives Limited 3 Alaska Power Systems Elfin Cove Tank Farm ID Owner 1 Elfin Cove Community Council 3/11/98 evaluation date capacity 7/22/96 10,698 7122196 998 7/27/96 2,000 total capacity 13,696 evaluation date capacity 11/7/96 2,000 11/7/96 68,000 total capacity 70,000 evaluation date capacity 10/17/97 45,990 10/17/97 29,330 10/17/97 60,000 total capacity 135,320 evaluation date capacity 9/4/96 102,465 total capacity 102,465 Site 10 Site 10 Site coo Site Diking 30 Diking 20 Diking 10 20 Diking 30 Found 10 Found 10 Found Found Tanks Piping Elec. Safety Total 0 10 0 0 10 0 10 0 30 90 0 10 0 0 10 total points 110 weighted average points/tank farm 15.83 Tanks Piping Elec. Safety Total O 10 oO 10 20 0 30 10 20 100 total points 120 weighted average points/tank farm 97.71 Tanks Piping Elec. Safety Total 5 10 0 10 40 5 50 10 40 130 0 0 0 0 0 total points 170 weighted average points/tank farm 41.77 Tanks Piping Elec. Safety Total 10 10 0 0 50 total points 50 weighted average points/tank farm 50.00 Page 7 of 26 Elim Tank Farm ID Owner 1A Bering Strait School District 1B Bering Strait School District 3 City of Elim 4 City of Elim 5 City of Elim 6 AK Army National Guard 7, ADOT Airport Emmonak Tank Farm ID Owner 1 Lower Yukon Schools 2 City of Emmonak 3 City of Emmonak 4 City of Emmonak 6 Lower Yukon School District 7A Emmonak Corporation 7B City of Emmonak 8 AC Company Store 9 Emmonak Corporation False Pass Tank Farm ID Owner 3 False Pass Power Plant 4 Aleutians East Borough School District 3/11/98 evaluation date capacity 9/18/96 30,250 9/18/96 27,160 9/18/96 49,840 9/18/96 56,590 9/18/96 36,000 9/18/96 4,500 9/18/96 3,000 total capacity 207,340 evaluation date capacity 10/2/97 40,000 10/1/97 11,300 10/1/97 28,000 10/1/97 40,000 10/1/97 128,000 10/2/97 380,000 10/2/97 52,200 10/1/97 20,000 10/2/97 41,148 total capacity 740,648 evaluation date capacity 8/8/96 34,000 8/8/96 968 total capacity 34,968 Site 10 10 10 10 10 Site 10 10 10 10 10 10 10 Site Diking 20 20 10 20 10 Diking 30 30 30 30 30 30 30 Diking Found 10 10 10 10 Found 0 10 0 0 10 5 10 0 0 Found 10 10 Tanks Piping Elec. Safety Total 10 0 0 10 40 0 10 0 10 50 10 20 0 10 70 0 20 0 10 70 10 20 0 10 60 0 0 0 0 20 0 10 0 0 20 total points 330 weighted average points/tank farm 59.46 Tanks Piping Elec. Safety Total 10 10 0 20 80 0 10 0 20 80 0 10 0 20 70 10 10 0 10 30 10 0 0 10 60 10 10 10 30 75 10 0 10 20 90 10 20 0 20 90 10 20 0 20 90 total points 665 weighted average points/tank farm 72.43 Tanks Piping Elec. Safety Total 0 20 10 30 70 0 10 0 10 30 total points 100 weighted average points/tank farm 68.89 Page 8 of 26 Fort Yukon Tank Farm ID Owner evaluation date capacity {) Yukon Fuel Co 7/25/96 73,800 2 Yukon Flats School District 7/23/96 47,000 3B Bureau of Land Management 7/25/96 2,700 5 BLM Alaska Fire Service 7/24/96 35,000 6 Gwitchyaa Zhee Corporation 7/25/96 24,000 7 White Alice 7/24/96 19,000 total capacity 201,500 Galena Tank Farm ID Owner evaluation date capacity 1 Gana A'Yoo/Galena Airport 7ASI97 100,000 4 Yukon Fuel Company 7/16/97 1,197,750 5 Yukon Fuel Company 7/16/97 100,000 6 Galena Power Plant 7/15/97 630,000 U Galena City School District 715/97 60,500 total capacity 2,088,250 Golovin Tank Farm ID Owner evaluation date capacity 1 City of Golovin 9/20/96 97,000 2 Bering Strait School District 9/20/96 59,400 total capacity 156,400 3/11/98 Site 10 oooono Site ooococo Site 10 Diking 20 20 10 20 10 Diking 30 30 Diking 10 Found 15 omoon Found 10 ooano Found Tanks _—— Piping Elec. Safety Total 0 0 0 20 47 0 20 0 20 65 0 0 0 0 10 0 0 0 0 0 10 20 10 20 85 0 10 0 0 20 total points 227 weighted average points/tank farm 44.52 Tanks _—— Piping Elec. Safety Total 0 5 0 20 65 0 5 0 0 5 10 10 0 20 75 0 5 0 10 15 0 0 0 0 0 total points 160 weighted average points/tank farm 14.10 Tanks _— Piping Elec. Safety Total 10 0 10 10 30 10 0 0 10 40 total points 70 weighted average points/tank farm 33.80 Page 9 of 26 Goodnews Bay Tank Farm ID 1 2 4 5 Hollis Tank Farm ID 1 Hoonah Tank Farm ID 1 2 3 6 8 3/11/98 Owner Lower Kuskokwim Schools Clinic/Washeteria National Guard Armory Mumtram Pikkai, Inc. Owner Alaska Power & Telephone Owner Hoonah Oil Company/L Kane Store Tlingit-Haida Regional Electric Association Hoonah City Schoo! District Hoonah Public Works Tlingit-Haida Regional Housing Authority evaluation date capacity 10/24/96 43,200 10/24/96 16,600 10/24/96 2,200 10/24/96 113,400 total capacity 175,400 evaluation date capacity 7/25/96 4,000 total capacity 4,000 evaluation date capacity 8/8/96 101,360 8/8/96 34,484 8/6/96 3,000 8/6/96 2,000 8/6/96 1,100 total capacity 141,944 Site coooo Site Site coooo Diking 20 Diking Diking Found 10 Found Found 10 cooo$o Tanks _—— Piping Elec. Safety Total 0 10 0 10 20 0 40 0 10 75 0 0 0 0 0 0 0 0 0 10 total points 105 weighted average points/tank farm 18.49 Tanks Piping Elec. Safety Total 0 10 0 10 20 total points 20 weighted average points/tank farm 20.00 Tanks _—— Piping Elec. Safety Total 0 20 0 30 90 0 10 0 0 10 0 0 0 0 0 0 20 0 20 70 0 0 0 0 0 total points 170 weighted average points/tank farm 67.68 Page 10 of 26 Hooper Bay Tank Farm ID 1 NOOO Ss w Hughes Tank Farm ID 1 2 3 Huslia Tank Farm ID 1 2 3 3/11/98 Owner Hooper Bay High School City of Hooper Bay Alaska Army National Guard Yukon Fuel Company (Cemetary North) Yukon Fuel Company (Cemetary South) Yukon Fuel Company Owner City of Hughes Hughes School City of Hughes Owner Yukon Koyukuk Schoo! district City of Huslia City of Huslia evaluation date 9/17/97 9/16/97 9/16/97 9/16/97 9/16/97 9/16/97 total capacity evaluation date 9/10/97 9/10/97 9/10/97 total capacity evaluation date 9/11/97 9/11/97 9/11/97 total capacity capacity 145,400 20,000 8,200 126,995 96,208 2,000 398,803 capacity 10,000 28,000 10,000 48,000 capacity 39,874 11,500 49,059 100,433 Site cooocco Site 10 10 10 Site 10 10 Diking 20 10 30 20 10 10 Diking 10 Diking 20 30 20 Found aanoona Found Found Tanks 10 10 0 10 10 0 weighted average points/tank farm Piping 10 10 20 30 20 5 Elec. Safety Total 0 20 65 0 10 40 10 20 80 0 10 75 0 10 55 10 20 50 total points 365 64.75 Tanks Piping Elec. Safety Total 0 5 0 20 35 0 0 0 10 30 0 0 0 0 10 total points 75 weighted average points/tank farm 26.88 Tanks _—— Piping Elec. Safety Total 0 45 0 20 85 0 30 10 20 100 0 10 10 30 85 weighted average points/tank farm total points 270 86.72 Page 11 of 26 Hydaburg Tank Farm ID Owner evaluation date capacity 1 Haida Oil Products 7/26/96 100,000 2 Alaska Power & Telephone 7/26/96 21,000 total capacity 121,000 Ivanof Bay Tank Farm ID Owner evaluation date capacity 1 Lake & Peninsula Borough School District 8/25/96 21,000 2 Ivanof Bay Village Council 8/25/96 22,600 3 PTI Communications 8/25/96 4,500 total capacity 48,100 Kake Tank Farm ID Owner evaluation date capacity 1 Kake Tribal Corporation 9/4/97 177,974 2 Tlingit Haida Regional Electrical Authority 9/4/97 67,296 4 Tlingit-Haida Senior Center 9/4/97 1,000 § City of Kake 9/4/97 3,563 6 Kake Hatchery 9/4/97 2,201 total capacity 252,034 3/11/98 Site Site Site cooco Diking Diking 30 Diking 30 coco Found Found 10 10 Found cooococo Tanks Piping Elec. Safety 0 10 0 0 0 0 0 0 total points weighted average points/tank farm Tanks Piping Elec. Safety 0 10 0 10 10 20 0 10 0 20 0 10 total points weighted average points/tank farm Tanks Piping Elec. Safety 0 10 0 10 10 30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 total points weighted average points/tank farm Total 10 10 8.26 Total 20 80 40 140 50.06 Total 40 coo 45.99 Page 12 of 26 Karluk Tank Farm ID Owner 3 Native Village of Karluk Kasaan Tank Farm ID Owner 1 Kasaan Power 2 Kasaan Bulk Fuel Klawock Tank Farm ID Owner 1 Klawock Island Fuels 2 Tlingit-Haida Regional Electric Authority Koliganek Tank Farm ID Owner 1 Southwest Region School District 2 New Koliganek Village Council 3 Alaska Power Systems 3/11/98 evaluation date capacity 11/24/96 50,000 total capacity 50,000 evaluation date capacity 7/25/96 19,992 7/26/96 10,208 total capacity 30,200 evaluation date capacity 7/26/96 120,000 7126/96 1,000 total capacity 121,000 evaluation date capacity 10/16/97 60,000 10/17/97 20,000 10/17/97 60,000 total capacity 140,000 Site Site Site Site ooo Diking Diking 25 Diking Diking 30 Found Found Found Found 10 Tanks Piping Elec. Safety Total 5 0 0 0 5 total points 5 weighted average points/tank farm 5.00 Tanks Piping Elec. Safety Total 0 10 0 20 55 0 10 0 20 30 total points 85 weighted average points/tank farm 46.55 Tanks Piping Elec. Safety Total 0 10 0 20 30 0 10 0 10 20 total points 50 weighted average points/tank farm 29.92 Tanks Piping Elec. Safety Total 10 0 0 10 25 10 60 10 40 160 0 0 0 0 0 total points 185 weighted average points/tank farm 33.57 Page 13 of 26 Kotlik Tank Farm ID Owner 1 Lower Yukon School District 2 Kotlik Yupik Corporation 3 Kotlik Electric Service 4 City of Kotlik 5 AC Store Koyuk Tank Farm ID Owner 1 Bering Strait School District 3 Koyuk Native Corporation 4 City of Koyuk 6 Koyuk Native Corporation 7 Bering Straits School District 8 ADOT, Airport Larsen Bay Tank Farm ID Owner 2 City of Larsen Bay 3 City of Larsen Bay 3/11/98 evaluation date 10/2/97 10/2/97 10/2/97 10/2/97 10/2/97 total capacity evaluation date 9/18/96 9/18/96 9/18/96 9/18/96 9/18/96 9/18/96 total capacity evaluation date 11/24/96 11/24/96 total capacity capacity 48,955 220,000 50,000 18,100 15,000 352,055 capacity 63,000 95,400 16,000 3,400 2,500 3,000 183,300 capacity 70,500 4,900 75,400 Site 10 10 10 Site 10 o 10 10 Site Diking 10 30 30 Diking 30 20 20 20 Diking 20 30 Found 15 10 10 Found 0 20 10 10 Found Tanks _—— Piping Elec. Safety Total 10 10 0 20 60 10 50 10 30 155 20 10 0 10 50 10 60 10 20 100 10 10 0 30 100 total points 465 weighted average points/tank farm 121.71 Tanks _—— Piping Elec. Safety Total 0 20 0 10 70 10 10 10 20 90 10 10 0 10 60 0 0 0 10 10 0 10 0 10 60 0 10 0 10 30 total points 320 weighted average points/tank farm 77.63 Tanks _—— Piping Elec. Safety Total 10 10 10 20 75 5 10 0 10 55 total points 130 weighted average points/tank farm 73.70 Page 14 of 26 Levelock Tank Farm ID Owner 1 Levelock Village Council 2 Lake & Peninsula School District 3 Levelock Village Council 4 Levelock Village Council Lower Kalskag Tank Farm ID Owner 2 Kuspuk School District 3 City of Lower Kalskag Manokotak Tank Farm ID Owner 1 Southwest Region School District 2 Manokotak Natives Limited Corp. 3 Manokotak Natives Limited Corp. 4A Manokotak Power Company 4B Manokotak Natives Ltd. 5 Alaska Army National Guard 6 Moravian Church 7 Manukutaag Trading Co. Store 3/11/98 evaluation date capacity 11/9/96 124,900 11/9/96 31,500 11/9/96 30,900 11/9/96 1,000 total capacity 188,300 evaluation date capacity 10/27/97 16,000 10/28/97 74,770 total capacity 90,770 evaluation date capacity 10/21/96 45,000 10/21/96 1,000 10/21/96 1,000 10/21/96 21,400 10/21/96 89,100 10/21/96 1,500 10/21/96 2,700 10/21/96 1,450 total capacity 163,150 Site cooos$o 10 Site Diking 10 20 20 Diking 20 15 Diking 20 30 20 20 30 30 Found ano Found Found 10 10 20 10 Tanks Piping Elec. Safety 0 10 0 10 10 20 0 10 0 30 0 20 0 30 0 10 total points weighted average points/tank farm Tanks Piping Elec. Safety 10 20 10 20 0 20 10 40 total points weighted average points/tank farm Tanks Piping Elec. Safety 0 15 0 10 0 30 0 10 0 30 0 10 0 30 10 20 0 30 10 20 0 10 0 0 0 30 0 10 0 10 0 10 total points weighted average points/tank farm Total 25 50 75 65 215 37.60 Total 85 100 185 97.36 Total 50 80 80 95 95 10 100 70 580 81.48 Page 15 of 26 Mekoryuk Tank Farm ID Owner 10 City of Mekoryuk 11 Nima Corporation 3 NIMA Corporation 4 NIMA Corporation 5 Alaska Army National Guard 6 Lower Kuskokwim School District a City of Mekoryuk 9 City of Mekoryuk Metlakatla Tank Farm ID Owner 1 Guthrie Fuel Service 2 Louisiana Pacific Ketchikan/Annette Hemlo 3 Annette Island Gas Service 4 Metlakatla Power and Light 5 Metlakatla High School Naknek Tank Farm ID Owner 10 Bristol Bay Borough 3 Naknek Electric Association 3/11/98 evaluation date 8/23/96 8/23/96 8/23/96 8/23/96 8/23/96 8/25/96 8/23/96 8/23/96 total capacity evaluation date 10/2/97 10/2/97 10/2/97 10/2/97 10/2/97 total capacity evaluation date 11/9/96 11/9/96 total capacity capacity 1,700 43,800 34,700 16,630 3,000 90,400 7,000 26,000 223,230 capacity 117,000 11,300 79,948 410,000 10,000 628,248 capacity 48,500 1,660,000 1,708,500 Site 10 10 10 10 10 10 Site ooococjo Site Diking Diking 20 Found Tanks Piping Elec. Safety Total 0 5 10 0 10 65 0 0 20 0 10 40 10 10 10 10 20 100 5 10 20 0 20 95 10 0 10 0 10 60 10 0 0 0 10 40 0 0 10 0 10 20 0 30 20 10 20 100 total points 520 weighted average points/tank farm 60.24 Found Tanks Piping Elec. Safety Total 10 10 30 0 20 100 0 0 10 0 0 10 0 10 10 0 10 60 0 0 10 0 0 10 0 10 10 0 10 30 total points 210 weighted average points/tank farm 33.44 Found Tanks Piping Elec. Safety Total 5 10 10 0 10 55 0 0 0 0 0 0 total points 55 weighted average points/tank farm 1.56 Page 16 of 26 New Stuyahok Tank Farm ID Owner evaluation date 1 Southwest Region Schoo! District 10/17/97 3 Stuyahok, Ltd. 10/17/97 total capacity Newtok Tank Farm ID Owner evaluation date 1 Newtok High School 9/19/97 2 Newtok Elementary School 9/19/97 3 Newtok Corp. Inc. (Store) 9/19/97 4 Newtok Corp., Inc. (Store) 9/19/97 5 Newtok Corp., Inc. Store & Ungusraq Powe 9/19/97 8 Alaska Army National Guard 9/19/97 total capacity Nightmute Tank Farm ID Owner evaluation date 1 Chinuruk, Inc. (Store) 8/25/96 2 Nightmute Power Co. Plant 8/25/96 3 Alaska Army National Guard 8/25/96 4 Nightmute Power Company Plant 8/25/96 5 Lower Kuskokwim School District 8/25/96 9 Nightmute Power Co. 8/25/96 total capacity 3/11/98 capacity 57,850 41,000 98,850 capacity 81,240 39,830 25,940 26,260 55,955 2,500 231,725 capacity 40,400 42,900 3,000 40,000 27,500 7,000 160,800 Site Site coooono Site 10 10 ooo Diking 30 Diking 10 20 30 30 30 30 Diking 20 30 30 10 20 20 Found Found 10 10 10 Tanks Piping Elec. Safety Total 10 20 0 10 45 10 20 10 40 110 total points 155 weighted average points/tank farm 71.96 Tanks Piping Elec. Safety Total 0 10 0 10 35 10 30 oO 10 75 10 0 10 10 60 10 10 10 20 85 10 30 0 10 85 0 0 0 10 40 total points 380 weighted average points/tank farm 62.47 Tanks Piping Elec. Safety Total 10 20 10 10 90 10 10 0 10 65 0 10 0 10 70 5 30 0 10 60 0 0 0 10 30 10 20 0 10 70 total points 385 weighted average points/tank farm 64.36 Page 17 of 26 Old Harbor Tank Farm ID Owner 3 Alaska Army National Guard Ouzinkie Tank Farm ID Owner 1 Ouzinkie Native Corp. Fuel Facility 2 Kodiak Island Borough School District 3 City of Ouzinkie Pelican Tank Farm ID Owner 1 Pelican Seafoods 2 Pelican City Schools Perryville Tank Farm ID Owner 1 Lake and Peninsula School District 2 Native Village of Perryville 3/11/98 evaluation date capacity 11/13/96 5,300 total capacity 5,300 evaluation date capacity 11/14/96 71,600 11/14/96 5,200 11/14/96 1,400 total capacity 78,200 evaluation date capacity 9/3/96 145,185 9/3/96 2,000 total capacity 147,185 evaluation date capacity 8/25/96 21,900 8/26/96 72,500 total capacity 94,400 Site Site 10 Site Site Diking 30 Diking 10 30 Diking 30 Diking Found 10 Found 10 10 Found Found 10 Tanks _—_— Piping Elec. Safety Total 0 20 0 10 70 total points 70 weighted average points/tank farm 70.00 Tanks Piping Elec. Safety Total 20 10 0 10 60 0 0 0 10 10 30 40 Oo 20 140 total points 210 weighted average points/tank farm 58.11 Tanks Piping Elec. Safety Total 0 10 0 0 40 0 0 0 0 0 total points 40 weighted average points/tank farm 39.46 Tanks Piping Elec. Safety Total 0 10 0 10 20 0 0 0 10 20 total points 40 weighted average points/tank farm 20.00 Page 18 of 26 Pilot Point Tank Farm ID t 2 3 4 Platinum Tank Farm ID 1 2 3 4 Owner City of Pilot Point City of Pilot Point Lake & Peninsula School District City of Pilot Point Owner Arvigq, Inc. Arig Inc. Power Plant Lower Kuskokwim School District Point Baker Tank Farm ID 1 3/11/98 Owner Point Baker Trading Post evaluation date 11/6/96 11/6/96 11/6/96 11/6/96 total capacity evaluation date 10/24/96 10/24/96 10/24/96 10/24/96 total capacity evaluation date 9/30/97 total capacity capacity 18,400 90,000 7,000 20,500 135,900 capacity 47,100 20,000 5,600 7,000 79,700 capacity 20,180 20,180 Site 10 10 Site 10 10 10 10 Site 10 Diking 10 30 30 Diking 30 30 10 Diking Found ano Found ano Found Tanks Piping Elec. Safety Total 0 30 0 20 75 0 10 0 10 60 0 10 0 10 25 10 0 0 10 55 total points 215 weighted average points/tank farm 59.47 Tanks Piping Elec. Safety Total 0 10 0 10 65 0 20 10 20 90 0 10 0 10 65 0 10 0 10 45 total points 265 weighted average points/tank farm 69.52 Tanks _—— Piping Elec. Safety Total 30 20 0 10 100 total points 100 weighted average points/tank farm 100.00 Page 19 of 26 Port Alexander Tank Farm ID Owner 1 Port Alexander School 2 Port Alexander Store 3 Pelican Cold Storage Port Heiden Tank Farm ID Owner 1 City of Port Heiden 2 City of Port Heiden 3 City of Port Heiden 4 Native Village of Port Heiden 6 Lake & Peninsula School District 7 Ak Department of Transportation Port Lions Tank Farm ID Owner q Port Lions Tribal Council 2 Kodiak Electric Association 3/11/98 evaluation date 8/29/97 8/29/97 8/29/97 total capacity evaluation date 8/29/96 8/25/96 8/25/96 8/25/96 8/25/96 8/25/96 total capacity evaluation date 11/13/96 11/13/96 total capacity capacity 12,212 2,000 0 14,212 capacity 35,000 428,000 4,500 55,000 15,000 5,000 542,500 capacity 90,600 1,100 91,700 Site o Site 10 10 10 Site Diking Diking 30 10 30 30 20 30 Diking 20 10 Found Found 10 10 10 10 0 0 Found Tanks Piping Elec. Safety Total 0 10 0 10 20 0 0 0 0 0 0 0 0 0 0 total points 20 weighted average points/tank farm 17.19 Tanks Piping Elec. Safety Total 10 30 10 30 130 10 10 0 10 50 10 20 0 10 90 30 20 0 20 110 30 20 0 20 90 30 10 0 20 100 total points 570 weighted average points/tank farm 63.14 Tanks Piping Elec. Safety Total 10 0 10 0 40 0 20 0 10 40 total points 80 weighted average points/tank farm 40.00 Page 20 of 26 Port Protection Tank Farm ID Owner 1 Wooden Wheel Cove Trading Post Rampart Tank Farm ID Owner 1 Yukon Flats School District Ruby Tank Farm ID Owner 1 State of Alaska, Dept. of Transportation 2 City of Ruby 3 Dineega Fuel 4 Yukon Koyukuk School District Scammon Bay Tank Farm ID Owner 1 Askinuk Corporation 2 City of Scammon Bay 4 Alaska Army National Guard 6 Lower Yukon Schools 3/11/98 evaluation date 9/30/97 total capacity evaluation date 7/14/97 total capacity evaluation date TIN7/97 TI6/97 7/6/97 7/17/97 total capacity evaluation date 9/17/97 9/17/97 9/17/97 9/17/97 total capacity capacity 24,094 24,094 capacity 47,500 47,500 capacity 4,000 12,000 194,800 65,610 276,410 capacity 132,800 10,800 3,000 60,100 206,700 Site 10 Site 10 Site 10 coo Site 10 Diking Diking Diking 30 30 10 20 Diking 30 30 Found Found Found ooo Found 10 Tanks Piping Elec. Safety 30 20 0 20 total points weighted average points/tank farm Tanks Piping Elec. Safety 0 30 10 30 total points weighted average points/tank farm Tanks Piping Elec. Safety 0 30 0 10 0 30 0 20 10 0 0 10 0 30 0 20 total points weighted average points/tank farm Tanks Piping Elec. Safety 0 0 0 0 10 5 0 30 0 0 0 10 10 40 0 20 total points weighted average points/tank farm Total 110 110 110.00 Total 115 115 115.00 Total 85 80 30 70 265 42.46 Total 0 95 40 75 210 27.35 Page 21 of 26 Sheldon Point Tank Farm ID Owner evaluation date capacity 1 Lower Yukon Schools 9/30/97 67,240 2 Swan Lake Corporation 9/30/97 95,423 3 State of Alaska, DOT 9/30/97 3,000 total capacity 165,663 South Naknek Tank Farm ID Owner evaluation date capacity 2 Bristol Bay Borough Schools 11/8/96 24,000 total capacity 24,000 Stebbins Tank Farm ID Owner evaluation date capacity 2 Bering Strait School District 9/18/96 101,000 3 Tapraq Fuel Company and City of Stebbins 9/18/96 111,800 5 Alaska Army National Guard 9/18/96 3,000 in ADOTiairport 9/18/96 3,000 total capacity 218,800 3/11/98 Site 10 Site Site 10 10 Diking Diking Diking 32 Found 10 Found Found 10 Tanks _—— Piping Elec. Safety Total 10 60 0 30 150 10 0 0 0 10 0 10 0 10 20 total points 180 weighted average points/tank farm 67.00 Tanks Piping Elec. Safety Total oO 20 0 10 60 total points 60 weighted average points/tank farm 60.00 Tanks Piping Elec. Safety Total 10 10 0 10 40 10 20 10 20 102 0 10 0 0 10 0 10 0 0 20 total points 172 weighted average points/tank farm 70.99 Page 22 of 26 Stevens Village Tank Farm ID Owner 1 Yukon Flats School District a Dinyee Corporation 3 Bureau of Indian Affairs Tanana Tank Farm ID Owner 1 Native Village of Tanana (IRA) 2 State of Alaska, DOT/PF 3 City of Tanana Washeteria 4 Tanana Power Plant Tatitlek Tank Farm ID Owner 1 Tatitlek Community School 2 Native Village of Tatitlek (IRA) 3 Native Village of Tatitlek (IRA) 4 State of Alaska, DOT&PF 3/11/98 evaluation date 7/25/96 7/25/96 7/25/96 total capacity evaluation date 77/97 7IA7/97 77/97 7/17/97 total capacity evaluation date 11/20/97 11/20/97 11/20/97 11/20/97 total capacity capacity 47,500 14,200 13,500 75,200 capacity 191,000 2,000 10,000 46,500 249,500 capacity 20,000 10,000 2,000 3,000 35,000 Site o Site ooo Site 10 10 10 10 Diking 10 Diking 20 30 30 30 Diking ooo Found Found 10 Found ooo Tanks Piping Elec. Safety Total 10 10 0 20 55 0 0 0 0 0 0 0 0 0 0 total points 55 weighted average points/tank farm 34.74 Tanks Piping Elec. Safety Total 0 30 10 20 80 0 50 0 20 100 0 30 0 20 90 0 50 0 20 100 total points 370 weighted average points/tank farm 84.29 Tanks Piping Elec. Safety Total 10 30 0 10 60 0 5 0 10 25 0 5 0 10 25 0 30 0 20 60 total points 170 weighted average points/tank farm 48.00 Page 23 of 26 Thorne Bay Tank Farm ID Owner 2 City of Thorne Bay 3 US Forest Service Togiak Tank Farm ID Owner 1 City of Togiak 10 Moravian Church 2 City of Togiak 4 Southwest Region School District 5 City of Togiak 6 Head Start Building 7 Togiak Traditional Council 8 Alaska Commercial Store 9 National Guard Armory Toksook Bay Tank Farm ID Owner 1 Lower Kuskokwim Schools 3 City of Toksook Bay 4 Nunakauiak Yupik Corporation 5 City of Toksook Bay 6 Alaska Army National Guard 7 City of Toksook Bay 3/11/98 evaluation date 7/23/96 7/23/96 total capacity evaluation date 10/23/96 10/22/96 10/22/96 10/22/96 10/22/96 10/22/96 10/22/96 10/22/96 10/22/96 total capacity evaluation date 8/23/96 8/23/96 8/23/96 8/23/96 8/23/96 8/23/96 total capacity capacity 6,000 20,455 26,455 capacity 2,500 1,900 27,900 59,400 209,500 1,000 1,000 2,000 2,000 307,200 capacity 34,460 11,400 120,020 9,300 5,000 5,300 185,480 Site Site 10 10 10 10 10 10 Site 10 10 10 Diking Diking 30 30 30 20 30 30 30 Diking 30 30 30 30 30 30 Found n ° Cc 3S Qa coganaaunaanae Found 20 coo Tanks Piping Elec. Safety Total 0 0 0 0 0 0 0 0 0 0 total points 0 weighted average points/tank farm 0.00 Tanks Piping Elec. Safety Total 30 20 10 30 130 0 0 0 10 45 0 5 10 10 70 0 5 0 10 50 30 20 0 20 115 0 30 0 10 75 0 10 0 10 55 0 0 0 10 20 0 0 0 0 10 total points 570 weighted average points/tank farm 96.41 Tanks Piping Elec. Safety Total 10 10 0 10 60 10 40 0 20 115 10 40 10 30 150 0 30 0 10 80 0 20 0 0 55 0 10 0 0 40 total points 500 weighted average points/tank farm 121.91 Page 24 of 26 Tununak Tank Farm ID Owner 1 Lower Kuskokwim School District Tununak Elders Council Lower Kuskokwim School District Tununrmiut Rinit Corp Store Tununrmiut Rinit Corp Store Alaska Army National Guard NOOAN Twin Hills Tank Farm ID Owner 1 Twin Hills Village 2 Southwest Region School District 3 Twin Hills Village Upper Kalskag Tank Farm ID Owner 2 Kuspuk School District 3 City of Upper Kalskag 5 Kalskag Store 6 Kuspuk School District 3/11/98 evaluation date 8/25/96 8/25/96 8/25/96 8/25/96 8/25/96 8/25/96 total capacity evaluation date 10/23/96 10/23/96 10/23/96 total capacity evaluation date 10/22/97 10/22/97 10/22/97 10/22/97 total capacity capacity 45,600 15,600 24,700 61,800 58,600 6,300 212,600 capacity 20,200 31,300 9,200 60,700 capacity 32,000 2,500 36,200 17,200 87,900 Site 10 10 10 10 Site ooo Site 15 10 10 Diking 0 30 10 20 30 30 Diking 20 20 20 Diking 30 30 20 30 Found 0 10 0 0 10 10 Found 0 5 Found 15 20 10 10 Tanks Piping Elec. Safety Total 10 20 20 10 60 20 20 10 20 120 20 10 0 20 70 10 10 0 10 60 10 30 0 20 100 0 10 0 10 70 total points 480 weighted average points/tank farm 76.89 Tanks Piping Elec. Safety Total 0 30 10 20 80 0 0 0 10 35 0 30 10 10 70 total points 185 weighted average points/tank farm 55.28 Tanks Piping Elec. Safety Total 5 30 10 40 145 5 10 0 20 95 10 10 0 20 80 0 10 0 10 60 total points 380 weighted average points/tank farm 100.18 Page 25 of 26 White Mountain Tank Farm ID 1 2 4 3/11/98 Owner White Mountain Native Store Bering Strait School District ADOT/Airport evaluation date capacity 9/18/96 43,500 9/18/96 131,600 9/18/96 3,000 total capacity 178,100 Site 10 0 10 Diking 20 10 0 Found 10 10 Tanks 10 10 Piping 30 10 10 Elec. Safety Total 0 20 100 0 20 60 10 10 40 total points 200 weighted average points/tank farm 69.43 Page 26 of 26 ATTACHMENT 2 DIVISION OF ENERGY TANK FARM EVALUATION CRITERIA Site Location Site suitable for tank farm 0 points < 100 feet from a public well 10 points < 25 feet from an eroding bank or beach, or in a flood plain 10 points Gasoline tanks < 25 feet from an important building 10 points 30 points max. Secondary Containment *Liquid-tight, lined dike of proper volume and construction (not plywood, 12” min. freeboard) 0 points *Liquid-tight, lined dike of improper volume or construction (plywood or < 12” freeboard) 10 points *Fully diked but not liquid-tight (sand bag dike, permeable gravel, torn or missing liner) 20 points *Partial or no dike 30 points 30 points max. Foundations *Tanks on acceptable foundations (min. 6” timbers, no cribbing, stable) 0 points “Tanks directly on gravel pad or light timbers (raised smail timbers, on permeable gravel) 5 points *Tanks directly on tundra or natural soils (no dike or liner, subject to erosion) 10 points Tanks leaning considerably or unstable foundations (seismic hazard) 10 points 20 points max. Tanks *Tanks in fair to good condition (no dents, minimum rust, no major repairs needed) 0 points “Immediate need of cleaning and painting 10 points *Rusted or dented beyond repair or riveted, bolted or other 30 points 30 points max. Piping (choose most likely to leak, i.e., victaulic, threaded or welded, only) “Welded piping above grade 0 points “Welded piping below grade 5 points “Threaded piping above grade 10 points *Threaded piping below grade 20 points “Victaulic piping above grade 30 points “Victaulic piping below grade 40 points Rubber hose 20 points Additional for active leaks 20 points 80 points max. Electrical Wiring appears appropriate 0 points Exposed wiring, improper grounding, etc. 10 points 10 points max. Life, Health & Safety *Code compliant 0 points “Low risk 10 points *Medium risk 20 points *High risk 30 points *Potential for loss of life 40 points 40 points max. *Indicates that only one of the group should be chosen. ATTACHMENT 3 3/11/98 Tank Farms Removed From Deficiency Rankings Community Owner Capacity (gal) Alakanuk AVEC 117,029 Aleknagik Moody's Marina & Sea Lighterage 44,700 Angoon Angoon Oil and Gas 95,000 Aniak Arctic Transportation Service 4,000 Aniak Steve Hill 21,000 Aniak Ryan Air 72,230 Aniak Moffitt Contracting Co. 333,000 Aniak Moffitt Contracting Co. 349,000 Aniak Hagelund Aviation Service 1,900 Bettles Brooks Range Aviation 6,100 Bettles Ace Supply Store 13,600 Brevig Mission AVEC 66,900 Chefornak John Agavok 8,445 Chevak AVEC 136,700 Chevak Wayne Hill Company Store 28,000 Chignik Bay Aleutian Dragon Fisheries 185,500 Chignik Bay Aleutian Dragon Fishery 3,000 Chignik Bay Aleutian Dragon Fishery 3,000 Chignik Lagoon Algot Anderson's residence 4,000 Chignik Lagoon Viola Grunette's residence 1,600 Chignik Lagoon Alfred Aboud's residence 2,500 Chignik Lagoon Private tank farm. 2,750 Chignik Lagoon Al Anderson 7,250 Chignik Lagoon Al Anderson's residence 5,600 Chignik Lagoon Jeff Moore's residence 3,700 Chignik Lake Tide Mark Company 14,500 Chignik Lake Tide Mark Company 2,000 Clarks Point Trident Seafoods 66,600 Clarks Point Trident Seafoods 10,000 Coffman Cove Louisiana Pacific Ketchikan 45,842 Coffman Cove Gas Plus 7,800 Cold Bay Frosty Fuel, Inc. 557,800 Cold Bay Peninsula Air 15,300 Cold Bay Russell Creek Hatchery 7,650 Page 1 of 4 3/11/98 Community Craig Craig Craig Craig Egegik Egegik Egegik Egegik Egegik Elim Emmonak Emmonak False Pass False Pass Fort Yukon Fort Yukon Fort Yukon Fort Yukon Galena Galena Goodnews Bay Goodnews Bay Gustavus Gustavus Gustavus Gustavus Gustavus Hoonah Hoonah Hoonah Hoonah Hooper Bay Hooper Bay Huslia Hydaburg Tank Farms Removed From Deficiency Rankings Owner Petro Marine Services Ward Cove Packi ing Ward Cove Packing Senior Apartment Egegik Fuel Company Woodbine Alaska Fish Company Nelbro Packing Company Egegik Trading company Dick Deigh AVEC AVEC Grant Air Services Peter Pan Seafoods Peter Pan Seafoods Frontier Flying Service Yukon Air Service Sheenjek River Air Service Trader Dan's Yukon Outpost Warbelow's Air Service Frontier Flying Service AVEC Goodnews River Fishing Lodge Dick Levitt Dick Levitt Dick Levitt Dick Levitt Whalesong Lodge Hoonah Cold Storage Ward Cove Packing Company Hoonah Trading Co. Whitestone Logging AVEC Little Flower of Jesus Parish AVEC Haida Apartment Building Capacity (gal) 320,010 1,100 4,000 1,100 44,400 98,000 52,000 2,000 14,400 70,850 172,247 133,000 320,700 1,000 10,500 6,000 4,100 3,500 37,000 30,000 67,300 10,000 108,740 9,432 2,938 7,520 1,000 1,971 6,100 212,105 71,257 160,900 2,519 67,174 1,000 Page 2 of 4 3/11/98 Tank Farms Removed From Deficiency Rankings Community Owner Capacity (gal) Kake SOS Value Mart 5,000 Kake Temsco Helicopters 1,000 Kasaan Norplex Lumber 10,000 Klawock Viking Lumber 19,984 Koyuk AVEC 71,250 Koyuk Beach (unknown) 6,500 Larsen Bay Kodiak Salmon Packers 128,900 Lower Kalskag AVEC 103,500 Mekoryuk Bering Sea Reindeer Products 15,900 Mekoryuk AVEC 84,900 Naknek Naknek Engine Sales & Service 2,500 Naknek Trident Seafoods Corporation 31,000 Naknek Peninsula Automotive 4,000 Naknek Nelbro Packing company 24,200 Naknek Paug-Vik, Inc., Ltd 5,200 Naknek Southwestern Alaska Contractors, Inc. 6,000 New Stuyahok AVEC 84,400 Newtok Tom's Store 4,125 Newtok Agayuvik Holy Family Church 3,000 Nightmute Unknown 2,700 Nightmute Our Lady of Perpetual Help Church 1,650 Old Harbor Old Harbor Fuel Company 76,400 Old Harbor AVEC 41,200 Perryville Unknown 9,000 Port Heiden Reeve Aviation 428,000 Port Heiden Reeve Aviation 45,600 Scammon Bay AVEC 81,200 Scammon Bay Catholic Church of Scammon Bay 1,000 South Naknek Ward Cove Packing Company 150,100 South Naknek Trident Seafoods Corporation 57,100 South Naknek Trident Seafoods 20,900 South Naknek Peter Pan Seafoods 15,000 Page 3 of 4 3/11/98 Tank Farms Removed From Deficiency Rankings Community Owner Capacity (gal) Stebbins AVEC 112,400 Stebbins Ferris General Store 26,800 Stebbins Charlie Steves (Residence) 3,000 Tenakee Springs Snyder Merchantile 71,869 Thorne Bay Petro Alaska 276,000 Thorne Bay Taquan Air 6,000 Thorne Bay The Tackle Shack 3,000 Thorne Bay Bayview Fuel & Tire 2,000 Togiak Togiak Lumber 1,700 Togiak AVEC 135,700 Toksook Bay AVEC 147,475 Tununak AVEC 79,800 Twin Hills Togiak Fisheries, Inc. 127,500 Upper Kalskag Ausdahl Mercantile 1,980 Upper Kalskag Ken Morgan 36,800 White Mountain Lodge 2,000 White Mountain Reindeer Farm 4,900 Page 4 of 4 ATTACHMENT 4 Bulk Fuel Storage Deficiency Rankings 81 Communities Assessed in 1996-97 Weighted Average Community Points per Tank Farm Chevak 127.9 Toksook Bay 121.9 Kotlik 121.7 Beaver 116.1 Rampart 115.0 Port Protection 110.0 Chignik Lagoon 109.7 Upper Kalskag 100.2 Point Baker 100.0 Egegik 97.7 Chignik Lake 97.4 Lower Kalskag 97.4 Chefornak 97.0 Togiak 96.4 Huslia 86.7 Tanana 84.3 Manokotak 81.5 Koyuk 776 Tununak 76.9 Alakanuk 74.7 Clarks Point 73.8 Larsen Bay 73.7 Brevig Mission 73.2 Emmonak 72.4 New Stuyahok 72.0 Chignik Bay 71.0 Stebbins 71.0 Old Harbor 70.0 Platinum 69.5 White Mountain 69.4 False Pass 68.9 Hoonah 67.7 Sheldon Point 67.0 Hooper Bay 64.8 Nightmute 64.4 Port Heiden 63.1 Newtok 62.5 Bettles 60.5 Mekoryuk 60.2 South Naknek 60.0 3/11/98 Community Pilot Point Elim Ouzinkie Allakaket Twin Hills Cold Bay Ivanof Bay Elfin Cove Tatitlek Kasaan Kake Fort Yukon Ruby Ekwok Port Lions Pelican Aleknagik Levelock Stevens Village Golovin Koliganek Metlakatla Aniak Klawock Scammon Bay Hughes Coffman Cove Hollis Perryville Alatna Goodnews Bay Port Alexander Craig Galena Hydaburg Karluk Naknek Angoon Thorne Bay Gustavus Tenakee Springs Weighted Average Points per Tank Farm 59.5 59.5 58.1 57.0 §5.3 50.7 50.1 50.0 48.0 46.6 46.0 44.5 42.5 41.8 40.0 39.5 37.8 37.6 34.7 33.8 33.6 33.4 33.3 29.9 27.4 26.9 20.0 20.0 20.0 20.0 18.5 17.2 15.8 14.1 8.3 5.0 1.6 0.9 0.0 All private All private