Loading...
HomeMy WebLinkAboutThe Western Gulf of Alaska 1974 THE WESTERN aL OF ALASKA A Summary of Available Knowledge ~ Masha pone 2 OF Oy arctic: Environmental Information and Data Center The Western Gulf of Alaska Ww Alaska °"" Gult LIBRS’ CRA DIVISION L- PLANN 3 FOREWORD This report is the result of a joint effort by the staffs of the University of Alaska's Arctic Environmental Information and Data Center (AEIDC) and Institute of Social, Economic and Government Research (ISEGR), under the direction of David Hickok and Victor Fischer, respectively. The overall coordination of the project was conducted by Richard T. Buffler and Eugene H. Buck of AEIDC. The following staff personnel had the primary responsibility for compiling data for the respective sections; Geomorphology-L. Lau, AEIDC; Climate-H. W. Searby, AEIDC: Oceanography-F. F. Wright, and R. L. Seitz, AEIDC; Geology-R. T. Buffler, AEIDC; Hydrology-L. Lau, AEIDC; Biota-E. H. Buck, K. Hulett, L. Lau, AEIDC; Socioeconomic- David Kresge, T. F. Gasbarro, S. Fison, ISEGR; Impact of Environment- Staff, AEIDC and ISEGR. Graphics for the project were supervised by E. Cote and were completed mainly by M. Aho with the assistance of S. Ward and R. Arend, AEIDC. Editing of the report was carried out primarily by L. McNicholas and J. Brogan, AEIDC. The report attempts to present all available factual cata in an unbiased manner. Portions of the text, however, reflect the individual staff member's personal experience and knowledge of the subject. Portions of the report also represent personal communications with numerous other persons. Research for the report and preparation of a primary draft was carried out during the months of July through October 1973. From November 1973 through January 1974, the draft was reviewed by the Bureau of Land Management, both the Division of Marine Minerals, Washington, D.C. and the Alaska OCS office, Anchorage. Concurrently, the draft was reviewed internally by AEIDC staff plus numerous other pertinent government and industry persons most knowledgeable about various aspects of the report. February and March 1974 were spent incorporating pertinent review comments and preparing the final report. TABLE OF CONTENTS Section Title Page I INTRODUCTION 1 PURPOSE AND SCOPE 1 GENERAL LOCATION AND 1 SETTING Il GEOMORPHOLOGY 5 INTRODUCTION 5 ALEUTIAN RANGE 11 ALEUTIAN ISLANDS 11 SHUMAGIN AND OTHER OFFSHORE 12 ISLAND GROUPS KODIAK MOUNTAINS 12 CONTINENTAL SHELF 13 CONTINENTAL SLOPE 14 ALEUTIAN TRENCH 17 ABYSSAL PLAIN 17 LITERATURE CITED 18 Ill CLIMATE 20 INTRODUCTION 20 DATA SOURCES 20 REGIONAL WEATHER PATTERNS 20 TEMPERATURE 30 PRECIPITATION 30 iii SURFACE WINDS 41 VISIBILITY 41 SKY COVER 50 SOLAR RADIATION 50 IMMERSION HYPOTHERMIA 52 LENGTH OF DAYLIGHT 52 LITERATURE CITED 56 OCEANOGRAPHY 57 INTRODUCTION 57 OFFSHORE CIRCULATION 58 INSHORE CIRCULATION 62 WATER TYPES OF THE WESTERN 71 GULF OF ALASKA MIXING PROCESSES AND NUTRIENTS 76 WAVES 79 TSUNAMIS 81 LITERATURE CITED 86 GEOLOGY 90 ONSHORE BEDROCK GEOLOGY 90 OFFSHORE BEDROCK GEOLOGY 101 GEOLOGIC HISTORY 109 ONSHORE SURFICIAL GEOLOGY 111 OFFSHORE SURFICIAL GEOLOGY 119 MINERALS 129 OIL AND GAS 137 OTHER ENERGY RESOURCES 146 VOLCANISM 154 SEISMICITY 162 COASTAL PROCESSES AND EROSION 167 LITERATURE CITED 173 VI HYDROLOGY INTRODUCTION 179 SURFACE WATER 179 GROUND WATER 186 LITERATURE CITED 189 VII BIOTA OF THE WESTERN GULF OF 190 ALASKA MARINE BACTERIA 190 PLANKTON 190 MARINE MACROPHYTES 200 BENTHIC AND INTERTIDAL INVERTEBRATES 202 PELAGIC FAUNA 263 TERRESTRIAL BIOTA 365 ECOLOGICAL SYSTEMS AND 379 MECHANISMS LITERATURE CITED 394 VIII SOC IOECONOMICS 410 GENERAL DESCRIPTION OF THE 410 STUDY REGION POPULATION AND EDUCATION 423 LABOR FORCE AND EMPLOYMENT 446 INCOME AND COST OF LIVING 460 HOUSING AND PUBLIC SERVICES 472 INDUSTRIAL ACTIVITY 482 TRANSPORTATION FACILITIES 510 AND COSTS LAND USE AND LAND STATUS $27 LITERATURE CITED 545 IX EFFECTS OF THE ENVIRONMENT ON 550 RESOURCE USE GEOMORPHOLOGY 550 CLIMATE-OCEANOGRAPHY 550 HYDROLOGY 551 GEOLOGY 552 BIOLOGY 558 LITERATURE CITED 560 X IMPACT AND CONFLICTS OF 561 RESOURCE USE POLLUTION 561 OTHER IMPACTS OF INDUSTRY 575 ACTIVITIES LITERATURE CITED 587 XI DATA GAPS INTRODUCTION GEOMORPHOLOGY OCEANOGRAPHY CLIMATE GEOLOGY HYDROLOGY BIOLOGY SOC IOECONOMICS LITERATURE CITED 592 592 592 592 593 593 594 595 597 598 vi THE WESTERN GULF OF ALASKA A SUMMARY OF AVAILABLE KNOWLEDGE I. INTRODUCTION PURPOSE AND SCOPE The purpose of this report is to provide a comprehensive description of the area known as the Western Gulf of Alaska (defined below). It is an attempt to summarize all currently available knowledge about the area using extensive graphics supplemented with a written text. A comprehensive reference list is included with each section to allow the reader to obtain additional detail. The report is designed to be used (1) as the basis for assessing potential environmental impacts that might result from Outer Continental Shelf (OCS) leasing activities, (2) for planning the development of OCS energy resources, and (3) planning the feasibility of coastal facilities development. The report consists, first, of a summary of currently available physical, biological and socioeconomic knowledge about the area (sections II through VIII). Included in these sections is a description of the area's resources and any industrial activity involving these resources-- past, present, and potential. Also included in the report is a discussion of present and potential conflicts and interactions between environmental considerations and resource uses, especially with regard to any future exploration for and production of petroleum on the Outer Continental Shelf (OCS). This is not a complete discussion, but it is an attempt to present examples of (1) what effect this environment might have on man's future activities in the area (section IX), and (2) what impact and conflicts might be expected with resource use, especially petroleum exploration and production (Section X). In addition, an attempt is made to define critical environmental data still needed to fully assess the impact of petroleum activities on the area (Section XI). GENERAL LOCATION AND SETTING The Western Gulf of Alaska study area comprises the continental shelf of the Gulf of Alaska and Pacific Ocean lying between Cook Inlet and Unimak Island (Figure 1). The area also includes that part of the adjacent coastal zone (including islands) directly influenced by, or having some influence upon, the marine environment. A map showing the location of all place names mentioned in the report is also included to aid the reader (Figure 2). Figure |, Location Map WESTERN GULF OF ALASKA KENAI-CHUGACH MOUNTAINS Vaviey of Ton. ‘Thousoné singe Aisktulle irk Coast Sd Stale Trinity te lamoco Cathedral ‘River Unit | Leoniviteya Sed Figure 2b, Place names, Western Gulf of Alaska and vicinity. II. GEOMORPHOLOGY INTRODUCTION The study area is characterized by steep, rugged mountains descending to the sea, a highly irregular coastline, and many islands and island groups (Figure 3). The coastline is indented by bays, inlets, lagoons, fiords, and natural harbors. Steep sea cliffs (10-50 m.), rocks, and an occasional narrow beach mark the shoreline (Wahrhaftig 1965). The continental shelf adjacent to the Alaska Peninsula extends seaward approximately 240 km. at its widest point. This shelf is marked by broad troughs and dotted with islands of varying size. Beyond the shelf, the continental slope descends steeply to the Aleutian Trench and the abyssal plain (Figure 3). The geomorphology of the study area reflects a combination of active tectonic processes (uplift and active volcanism), constructional (depositional) and destructional (erosional) processes. Considerable data are available describing the coastal zone. In particular, Wahrhaftig (1965) and Williams (1958) can be consulted for general descriptions. More detailed accounts can be obtained from (1) old expeditionary reports like the Harriman expedition (Merriam 1901), (2) geological surveys (Capps 1937, Atwood 1911); and (3) the Coastal Pilot (Coast and Geodetic Survey 1964). Most of the area is adequately covered by topographic maps of scale 1:250,000 and 1:63,360 (Figure 4). In general, not much is known about the offshore area. National Ocean Survey (Coast and Geodetic Survey) nautical charts show the general nature of the bottom. The availability of soundings and other data used to compile these charts varies. Some areas such as around Kodiak Island have more data available, as reflected by the more detailed chart coverage (Figure 5). Areas further offshore covered only by the smaller scale charts have relatively few bottom data available. A detailed bathymetric map covering most of the study area has been provided by von Huene and Shor (1969) (Figure 6), and Scripps Institution of Oceanography has compiled a generalized bathymetric map of the North Pacific (Chase et al. 1970). Detailed bathymetry of the entire Aleutian Arc including the southwest portion of the study area is available from an Environmental Science Services Administration map series (Coast and Geodetic Survey, undated). A generalized bathymetric map of the entire study area compiled from these three sources is presented here (Figure 7). Detailed bathymetric maps of the area produced from available data are also available for a fee from Continental Shelf Data Systems, Denver, Colorado. Figure 3. Physiogravhic diagram and physiographic provinces, Western Sulf of Alaska (a- dapted from von Iluene and Shor 1969). | ” oa a SCALE VERTICAL EXAGGERATION X10 tet 0 ete wae, INDEX MAP OF ALASKA Figure 4, S| <3» ote a Sty a | ele we = ad od teloe . alae aaeael ACEP ox Index of topographic map ; " ae Rel ela coca ., es ~ coverage, Western Gulf of | NAKNEK(S) tt Es mar Alaska (from U.S. Geologi- elle wee ee Peer |S . ae f eles ero 2. cal Survey 1973). versa he Pepa eee 58° —— 7 . 2 Sle aa Shel of i = ttt eis NS L ase karan ae ROD Layse T Oo BRISTOL BAY, RSHIR MA NK? pe 1s Aare) ee : B R Zs son bah Y ex sale] a CHEK NITY ISI wo wloia|-ol alebalss — TRINITY ISLA se . Fl Sere Sle > sefungals: anos COLD . 2, J os, a, ser] Jape! ee reese foe ef RS Oy we se" el Sleplaale Dh Ls 156° anf i i TEPOVAK BAY se 1929. - 963 2 LO et + é) ° Unimak fsiand’®, sgaealet . = wd, taka ste La oe - 7 } rome rad | 3 els 4% ko] 5 X< Lee] OS oe % & val TOPOGRAPHIC MAPS PUBLISHED AT THE SCALE YY — * Popes] = >, > OF 1.250.000 Sovak 'SLANL. a 15 cover maps se all of which are S FALSE PASS(S) SIMEQNOF ISLAND tome thay tamag se 8 stat bain content nd ie a 963 heed ree! etitons ae arable Orders seu sot etch i = sere agian ease — Tai T'S Sine senaced bs ne Storr Yovesionme Sones nau sf} manera = ska a 164" . , ° 162" 160° 158 y b TOPOGRAPHIC MAPS PUBLISHED AT THE SCALE a OF 163.360 r— . tar (iso esocseges seoid acae tee 1750000 cute 168) og ae ———<— % 66" {Ceample shown 18 FAIRBANKS. D | fr O° 0 0 100 150 KILOMETERS LAKE_CLARK (S) 1942-46 (RC) 150° FAIRBANKS (S) 1983 164° 162° 160° 158° 156° 154° 152° 150° Figure 5. Index of nautical chart coverage, Western Gulf of Alaska (from National Ocean Survey 1975). Numbers refer to National Ocean Survey (Coast and Geodetic Survey) chart num- bers. or 37 85+ SHUMAGIN PIISLANDS 150° 136° BATHYMETRIC MAP EASTERN ALEUTIAN TRENCH AND NORTHERN GULF OF ALASKA By CHARLES | WINEGARD AND ROLAND VON HUENE NAUTICAL MILES, 20 3¢ 40 30 60 ae SY" 50 60 Wo KILOMETERS “CONTOUR INTERVAL 200 METERS YOO AND 150- METER SUPPLEMENTAL CONTOURS CoMPRED *noM SCRIPPS INSTITUTION OF OCEAMOORAPIY 1904 Kavax CRUISE NMA ORONANCE, TEST STANON W003 oANis couse USC ANO GS EARTHOUAKE INVESTIORTIONS 1986, COLLECTION SHEET #700 1048-1902, CHART 8808, 1988 oA \ -t 134° Be 152" 0° c unr A vse" tae Z (io \ , Py rs we we OPS & - ‘ oe Hh : ee ¢ = ° Mo of oo TS = ——$#, coe ° Y sl, pF Tae" Yaar Iso v 37° ° PRATT ‘SEAMOUNT so Figure 6. 138" 136° Bathymetric map of a portion of Western Gulf of Alaska (from von Hluene and Shor 1969). Figure 7. Generalized bathymetric map, Western Gulf of Alaska. Depth in meters. (Adapced from von Huene and Shor 1369, Chase et al. 1970, and Coast and Geo- detic Survey. Undated. 1 a : 11 Other studies by von Huene (1972) and von Huene et al. (1971, 1972) provide additional descriptive information for the offshore area. Excellent descriptions of the offshore areas also are included in the results of recent Soviet fisheries investigations in the northeast Pacific (Gershanovich 1968, Gershanovich et al. 1964). In this report, description of the geomorphology is divided into physiographic provinces (Figure 3). Onshore areas described are the Aleutian Range, the Aleutian Islands including Unimak Island and the southern Alaska Peninsula, the Shumagin and other island groups off the southern Alaska Peninsula, and the Kodiak Mountains. Offshore areas considered are the continental shelf, continental slope, Aleutian Trench and abyssal plain. ALEUTIAN RANGE The Alaska Peninsula is divided into two provinces, the Nushagak- Bristol Bay Lowland and the Aleutian Range. The Nushagak-Bristol Bay Lowland is a glacial moraine and outwash-mantled lowland flanking the Aleutian Range on the northwest. The Aleutian Range forms the high, mountainous backbone of the Alaska Peninsula. The core of the range consists of folded Mesozoic and Tertiary rocks, upon which many recent and active volcanic centers are superimposed. These volcanoes form the higher peaks, ranging from approximately 1,000 m. to over 2,400 m. (Veniaminof Volcano), and display a spectacular assortment of recent volcanic features (calderas, craters, cones, etc.). Glacial features abound along the entire length of the range (cirques, U-shaped valleys, paternoster lakes, etc.). Fairly large glaciers still remain on a few of the higher volcanoes (Mt. Veniaminof, Mt. Katmai area, Mt. Douglas area), and small cirque glaciers occur on many of the other peaks. The firn line is approximately 1,000 m. The Pacific coast of the Aleutian Range is characterized by high, rugged cliffs that rise abruptly from the sea as well as many indentations. Many offshore reefs and shoals occur as well. Streams draining the coast are short, steep, and swift, often plunging directly into the sea as waterfalls. The crest of the range is rarely more than a few kilometers from the coast--30 km. at the most. ALEUTIAN ISLANDS The Aleutian Islands form a 2,250 km. long arcuate ridge rising 3,600 m. above the sea floor. This ridge is capped by many volcanoes ranging from 600 to over 2,700 m. above sea level. The study area west of Pavlof Bay is considered as part of the Aleutian Islands (Wahrhaf- tig 1965). The coast of the islands is rugged and irregular, similar to the Aleutian Range, but volcanic features such as lava flows are 12 more dominant, and low wave-cut platforms are characteristic features. The larger volcanic peaks have been intensely glaciated, and a fairly large glacial system still persists on Shishaldin Volcano. SHUMAGIN AND OTHER OFFSHORE ISLAND GROUPS The area offshore of the southern Alaska Peninsula is dominated by several island groups, the largest of which is the Shumagin Island Group. This group consists of 15 sizable islands and many smaller islets and rocks. Most of the islands are bold and mountainous. Parts of the islands have a somewhat rolling topography. The highest peak on Unga Island rises over 600 m. above sea level. Total land area of the islands is approximately 6,000 sq. km. The shoreline is rocky, precipitous, and irregular, similar to the Alaska Peninsula described above. Several other smaller islands and island groups occur off the southern Alaska Peninsula, the more prominent being the Sanak Islands and the Semidi Islands. All of these appear to have characteristics similar to the Shumagin Islands and the Alaska Peninsula coast described above. KODIAK MOUNTAINS The Kodiak Mountains are formed by the Kodiak Island Group (Kodiak, Afognak, Shuyak, Raspberry, and associated smaller islands), as well as the Barren and Trinity Island groups, and Chirikof Island. Geologically they constitute a southwest continuation of the Kenai-Chugach Mountains. Exclusive of the Barren Islands and Chirikof Island, the area covered by the Kodiak and Trinity Island Groups equals approximately 17,000 sq. km. The Kodiak Mountains area has a highly dissected, fiord indented, rugged coast. At one point on Kodiak Island the opposite coasts are separated by only 13 km. of land. Summit altitudes vary between 60 m. (Tugidak Island) and 1,340 m. (Kodiak Island), with Afognak having a maximum elevation of 730 m. (Karlstrom and Ball 1969). The Kodiak Island Group has a rugged, granitic northeast-trending divide with horns and aretes from which broad, smooth ridges extend northwestward. As on the Peninsula, streams are short and swift, lakes are small, and small ponds are widely scattered. Most of the area has been glaciated, as indicated by the presence of abundant glacial features throughout the area. Only one area on southwest Kodiak Island escaped glaciation during the last glacial period (Karlstrom and Ball 1969). On Kodiak Island the firn line is approximately 1,000 m. along the main divide, which still shelters at least 40 small cirque glaciers all less than 2 miles long (Wahrhaftig 1965). CONTINENTAL SHELF The continental shelf in the study area ranges in width from 240 km. north of the Kodiak Island Group to about 50-65 km. off Unimak Island (Figure 7). The total area covered by the shelf is computed to be approximately 155,000 sq. km. Relief on the shelf is due primarily to tectonic processes modified by erosional and depositional processes. Geological surveys of the Gulf of Alaska have been made by the Soviets in connection with fisheries investigations of the northeast Pacific. Much of the following description of the shelf is summarized from reports of these investigations (Gershanovich et al. 1964, Gershano- vich 1970). The shelf can be differentiated into three main parts--nearshore areas, plateau-like surfaces, and sea valleys (Gershanovich 1964, 1970). Nearshore areas comprise the narrow, shallow parts of the shelf adjacent to the coastline. These areas generally range between 5 to 8 km. in width and down to 30-50 m. in depth. They include many reefs and skerries (stacks) as well as the submerged coastal slopes, and represent sites of active coastal erosion. They are characterized in places by deep inlets or fjords, such as those found in Chignik Bay or northwest Kodiak Island (Figure 6). The main part of the shelf is characterized by large, broad, plateau- like surfaces with depths ranging from 80 to 120 m. and low bottom grades of 1-5 minutes. Examples of these surfaces are seen southwest and southeast of Kodiak Island. These plateau-like surfaces are interrupted in places by many isolated banks and shoals that rise, often abruptly, above the general level of the surface. Some of these even rise to above sea level and form islands, reefs, or skerries. All of them are characterized by an irregular and dissected relief, suggesting that they have been subjected to subaerial erosion by streams or glaciers during periods of lower sea level. Of special interest are the banks and shoals occurring along the shelf edge, which apparently represent tectonically uplifted areas characterized by truncated bedrock and fault scarps on the sea bottom. Albatross Bank off Kodiak Island is an excellent example of one of these shelf edge banks. It extends along the shelf edge for almost 80 km. with a rugged, dissected topography in part that shallows to between 15 and 20 m. in places. The outer shelf edge break is very distinct, but heavily dissected in profile. It ranges in depth from 120 to 130 m. off Unimak Island to 150-160 m. off Kodiak Island. 14 The plateau-like areas of the shelf are separated from each other by broad, flat-bottomed depressions or sea valleys that appear to fall into two categories. First are large sea valleys that trend parallel or subparallel to the shelf and probably represent large- scale tectonic depressions or areas of active subsidence. They have broad, flat bottoms and steep sides with 1-3 degree slopes. Shelikof Strait represents this type of sea valley and is approximately 300 km. long, 40.5 km. wide, and almost 300 m. deep along its northern edge (Figure 6). It is separated by a 100m. sill from another similar depression that extends to the continental margin, but it is cut off from the continental slope by another sill at the shelf edge. These large-scale sea valleys may have been significantly modified by fluvio- glacial processes during periods of lower sea level, as suggested by terraces on the slopes and banks of the sea valleys. The second type of sea valley is the smaller one, oriented transverse to the shelf and extending offshore from bays and inlets. They also have broad, level bottoms ranging from 10-50 km. wide and steep sides with 2-3 degree slopes. A longitudinal profile along the valleys commonly shows the middle to be deeper than the outer shelf margin forming closed depressions. They may represent valleys eroded by glacial- fluvial processes during lower stands of sea level. Excellent examples of these valleys occur off the southeast coast of Kodiak Island (Figure 6). Another feature of the shelf not mentioned above, but discovered recently by U.S. Geological Survey investigations, is a prominent fault zone extending parallel with the shelf from Prince William Sound to just opposite Kodiak (von Huene et al. 1971, 1972). Many of the faults have a sharp bathymetric expression with scarps facing both seaward and landward, indicating fairly recent deformation of the sea floor. Some of this deformation probably took place during the 1964 earthquake. CONTINENTAL SLOPE Adjacent to the continental shelf is a steep, rugged continental slope that drops more than 5,000 m. to the Aleutian Trench in a distance of 30-80 km. The slope off Kodiak Island has been studied in some detail by the U.S. Geological Survey, providing a much more detailed bathymetric map for a portion of the slope (Figure 8); (von Huene 1972, Piper et al. 1973). In this area, the slope can be separated into three subprovinces--a relatively smooth upper slope, a bench-like middle slope, and a steep, rough lower slope (Figure 9). Slope angles generally vary between 3 and 10 degrees, but angles of 20-30 degrees are common and angles of even 40 degrees are found in places along the lower and middle portions. The most characteristic feature of the slope are the benches. They commonly have raised outer rims comprised ‘p “hE Ss Figure 8. Detailed bathymetric map of portion of continental slope and Ajeutian Trench off Kodiak. Contour interval is 200 m. S denotes areas of slump at base of slope (from von Hucne 1972). CONTINENTAL Figure 9. Tracings of seismic records from continental margin off Kodiak showing details of continental slope, Aleutian Trench and abyssal plain. VE is vertical exaggeration at sea floor. SLOPE Vertical scale in seconds of two-way travel time. Lo- cation of sections shown on Figure 8. (From von Huene 1972). ALEUTIAN TRENCH ABYSSAL PLAIN 17 of folded sedimentary rocks and inner depressions filled with ponded sediments (Figure 9). These benches apparently were formed by the backward rotation of large landslide blocks, representing large-scale downslope movements along an oversteepened slope. Also characteristic of the slope are small, oblique canyons and ridges as well as closed depressions and hills 1-4 km. across and 70 m. high. The irregular nature of the slope-trench boundary probably represents large-scale slumping of the steep lower slope into the trench (Figure 8 and 9). Reports of Soviet investigations also contain good general descriptions of the continental slope in the Gulf of Alaska region (Gershanovich et al. 1964, Gershanovich 1970). ALEUTIAN TRENCH The portion of the Aleutian Trench between Middleton Island and the Shumagin Islands off Kodiak has been designated the Eastern Aleutian segment (von Huene and Shor 1969). This segment is approximately 1,380 km. long, over 5,000 m. below sea level, and slopes gently along its axis about 1.6 m./km. to the southwest. It basically consists of an asymmetrical, flat-floored, sediment-filled depression about 20-30 km. wide (Figure 9);(von Huene and Shor 1969, von Huene 1972, Piper et al. 1973). This gentle topography is interrupted only by the Kodiak Seamount, the westernmost of a chain of seamounts extending across the Gulf of Alaska (Figure 6). ABYSSAL PLAIN The abyssal plain is a relatively smooth, flat-lying depositional surface that slopes generally less than 1.5 m./km. but steepens to 50 m./km. (2-3 degrees) as it merges with the Aleutian Trench (Figure 9). Recent data concerning the abyssal plain in the Gulf of Alaska is presented by Hamilton (1967, 1973). Literature Cited Atwood, W.W. 1911. Geology and Mineral Resources of Parts of the Alaska Peninsula. U.S. Geological Survey. Bulletin No. 467. 137 pp. Capps, S.R. 1937. Kodiak and Adjacent Islands, Alaska. U.S. Geological Survey. Bulletin No. 880-C. pp. 111-184. Chase, T.E., H.W. Menard and J. Mammerickx. 1970. Bathymetry of the North Pacific (Map). Scripps Institution of Ocean- ography and Institute of Marine Resources, University of California, San Diego. Coast and Geodetic Survey. 1964. United States Coast Pilot 9, Pacific and Arctic Coasts, Alaska, Cape Spencer to Beau- fort Sea. U.S. Department of Commerce. 347 pp. Coast and Geodetic Survey. Undated. Unimak Bathymetry of the Aleutian Area (Map). U.S. Department of Commerce, Environmental Science Services Administration. Gershanovich, D.E. 1968. "New Data on the Geomorphology and Recent Sediments of the Bering Sea and the Gulf of Alaska."' Marine Geology 6(4) :281-296. weology Gershanovich, D.E. 1970. "Principal Results of Latest Investigations of Bottom Relief and Sediments in Fish Grounds in the North Pacific Ocean." In: Soviet Fisheries Investigations in the Northeast Pacific Ocean. Part V. All-Union Scientific Re- search Institute of Marine Fisheries and Oceanography (VNIRO). Trudy Vol. 70. P.A. Moiseev, ed. pp. 7-34. Transl. by Israel Program for Scientific Translations. Gershanovich, D.E., B.N. Kotenev, and V.N. Novihov. 1964. "Relief and Bottom Sediments of the Gulf of Alaska.'"' In: Soviet Fisheries Investigations in the Northeast Pacific Ocean. Part III. All- Union Scientific Research Institute of Marine Fisheries and Ocean- ography (VNIRO). Trudy Vol. 53. P.A. Moiseev, ed. pp. 74-125. Transl. by Israel Program for Scientific Translations. Hamilton, E.L. 1967. "Marine Geology of Abyssal Plains in the Gulf of Alaska." J. Geophysical Research 72(16) :4189-4213. Hamilton, E.L. 1973. 'Marine Geology of the Aleutian Abyssal Plain." Marine Geology 14(5):295-325. Karlstrom, T.N.V. and G.E. Ball, eds. 1969. The Kodiak Island Refugium, Its Geology, Flora, Fauna, and History. Ryerson Press, Toronto. 262 pp. 18 19 Merriam, C.H. ed. 1901. Harriman, Alaska Expedition. 14 Volumes. Mer- riam Publishing Co. New York. (Published in cooperation with Washington Academy of Sciences). National Ocean Survey. 1973. Nautical Chart Catalog 3, United States, Alaska, Including the Aleutian Islands. U.S. Department of Com- merce, National Oceanic and Atmospheric Administration. Piper, D.J.W., R. von Huene, and J.R. Duncan. 1973. "Late Quaternary Sedimentation in the Active Eastern Aleutian Trench." Geology 1(1): 19-22. U.S. Geological Survey. 1973. Index to Topographic Maps of Alaska (Map). U.S. Department of the Interior. von Huene, R. 1972. "Structure of the Cornitinental Margin and Tectonism at the Eastern Aleutian Trench." Geological Society of America Bul- letin 83:3613-3626. von Huene, R. and G.G. Shor, Jr. 1969. "The Structure and Tectonic His- tory of the Eastern Aleutian Trench." Geological Society of America Bulletin 80:1889-1902. von Huene, R., E.H. Lathram and E. Reimnitz. 1971. "Possible Petroleum Resources of Offshore Pacific-Margin Tertiary Basin, Alaska." American Association of Petroleum Geologists Memoir 15 1:136-159. von Huene, R., G.G. Shor, Jr. and R.J. Malloy. 1972. "Offshore Tectonic Features in the Affected Region."' In: The Great Alaska Earthquake of 1964: Oceanography and Coastal Engineering. National Academy of Sciences, Washington, D.C. pp. 266-289. Wahrhaftig, Clyde. 1965. Physiographic Divisions of Alaska. U.S. Geolog- ical Survey. Professional Paper No. 482. 52 pp. Williams, Howel, ed. 1958. Landscapes of Alaska. University of Cali- fornia Press, Berkeley and Los Angeles, California. Cambridge University Press, London, England. 148 pp. 20 TIT. CLIMATE INTRODUCTION The climate of the study area is dominated by a strong marine ‘influence. It is characterized by cloudy skies, moderately heavy precipitation, and cool temperatures. In winter, the waters of the North Pacific provide the moisture for cloudiness and precipitation and the heat that keep temperatures relatively mild. In summer, the water still provides moisture for precipitation and cloud cover, but the water is cooler than the air and temperatures remain moderate. A major west to east storm track lies along the southern portion of the area 10 months of the year. Surface winds are much stronger and more persistent than at inland stations. The mountains of the West- ern Gulf area exert a strong influence on precipitation, which in- creases with elevation. DATA SOURCES Figure 10 is a map showing the location of all weather stations used in this report. Parameters observed at these stations, data routinely summarized, and current status of each station is shown in Table 1. Detailed summaries of climatic data have been compiled for Kodiak and Cold Bay by the Air Weather Service (AWS), U.S. Air Force. Data for all other locations are taken from Environmental Data Service (NOAA) publications and include only temperature and precipitation. The source of wind data for Cape Sarichef is unknown (probably AWS) and for Sand Point is the U.S. Army Corps of Engineers. The periods of record for all stations are noted on the appropriate tables and figures. The Gulf of Alaska Operators Committee, a consortium of petroleum companies operating in the Gulf of Alaska, has completed a study of oceanographic and climatologic conditions of the Gulf of Alaska. A summary is available from the Committee, but detailed data is still proprietary information. REGIONAL WEATHER PATTERNS Mean surface and upper air patterns for the study area, based on 20 years of record, are shown in Figure 11 (U.S. Weather Bureau 1952). Superimposed on the surface patterns are major and secondary storm tracks (Klein 1957). A strong seasonal change in pressure patterns (between winter and summer) occurs both at the surface and aloft. The frequency of storms in the study area, based on 40 years of weather charts, is shown in Figure 12 (Klein 1957). Regional patterns of temperature and precipitation are shown in Figures 13 and 14. A more detailed discussion of the climatic parameters of the study area follows. 164° 162° 160° 158° 456° 154° 152° 150° Figure 10. Location of Weather 59° Stations, Western Gulf of Alaska. 58° 57° 57° 56° 55° 55° 54° 54° ‘ 158° 156° 154° 152° 150° It S 3 s z | s g Bo «| 9 a 6} 3 3 & ay 8 @ D g) a a 5| 0 2 al o «| 2 Pl mis | o| 3 3| 2 S| 301 2 | S| 2 ° aio] Oo 3] a 1 mt ao ne 6] cs | e} a a} 2] a ae a and a} als|alol|s -——-—- Kodiak x Cold Ba x{|x{x[ x] x] ~ *< Kitoi Bay_ Sitkinak Chignik |Cape Sarichef haba ee bebe Te Larsen Bay Parameters listed to the right of "24 hour precipitation" are observed but not routinely summarized except at Kodiak and Cold Bay. In addition they are not observed on an hourly basis except at Kodiak and Cold Bay, which is a major reason why they are not summarized. Even limited coverage timewise would have some value, and this data could be summarized if a user felt his needs justified the cost. Table 1. Data Stations and Parameters Observed, Western Gulf of Alaska (from Environmental Data Service [NOAA]). 22 —— Major Storm Track wee fp Minor Storm Track April Surface 850 millibar (mb) level 700 millibar (mb) level Figure 11. Mean Pressure Patterns, Alaska and North Pacific. Twenty years of record. Isolines on the surface re chart are mb's of pressure, the 850 and 700 mb charts are heights in 10's of meters (from U.S. Weather wa Bureau 1952 and Klein 1957). Major Storm Track eee ag Minor Storm Track August 850 millibar (mb) level Figure 11. Mean Pressure Patterns, Alaska and North Pacific. Twenty years of record. Isolines on the surface (Cont'd.) chart are mb's of pressure, the 850 and 700 mb charts are heights in 10's of meters (from U.S. Weather PS Bureau 1952 and Klein 1957). * Surface 850 millibar (rb) level 700 millibar (mb) level Figure 11. Mean Pressure Patterns, Alaska and North Pacific. Twenty years cf record. Isolines on the surface h (Cont'd.) chart are mb's of pressure, the 850 and 700 mb charts are heights in 10's of meters (from U.S. Weather Bureau 1952 and klein 1957). February TTT \\r ao< |\ Figure 12. Storm Frequency, North Pacific. Percentage frequency of the number of days with lows or storm centers in five degree squares. Forty years of record (Navy Hydrographic Office 1961). ij A ITHWESTERN 7 ~~~~/ > 4 yy JUTHWESTERN/ ~~ —fS ' 7 Cote | pe i~ sl slat F fe. Mean Maximum Temperature, degrees F Figure 13. Regional Temperature Distribution, Western Gulf and Southwest Alaska (from Environmental Data Ser- vice [NOAA]). 872 Mean Annual Precipitation (inches) Mean Annual Snowfall (inches) Includes water equivalent of snow Figure 14. Regional Precipitation Distribution, Western Gulf and Southwest Alaska (developed by National Weather Service in cooperation with the U.S. Geological Survey 1973). 6Z 30 TEMPERATURE Temperature patterns are characterized by relatively cool summers and warm winters, as compared to interior land temperatures at similar or more northerly latitudes. The temperature range between stations in the area is small, the greatest temperature variation being only 6 degrees F (3 degrees C), despite differences in exposure and distances from each other. Individual stations also show small ranges between mean annual maximum and minimum temperatures and extremes. The greatest range between the average annual maximum and minimum is 14.7 degrees F (9.6 degrees C). In comparison, Fairbanks, a typical inland station, has a maximum-minimum range of 22.8 degrees F (12.7 degrees C). The greatest range of extreme temperatures in the study area is 94 degrees F (52 degrees C), compared to Fairbanks which varies 165 F degrees (92 C degrees). Extreme temperatures in the Western Gulf are not per- sistent for more than a few days at a time. Average temperature differences between air and water are greatest during fall and winter when the air is as much as 5 degrees F (3 degrees C) colder than the water. This unstable condition results in vertical mixing of the air, maintaining clouds at a higher level than during spring and summer months when the air is more stable and slightly warmer than the water. Detailed temperature information is provided in Table 2. Percent- age frequency of occurrence of the complete range of temperature for Kodiak and Cold Bay is shown in Figure 15. Sea temperatures and sea- air temperature differences are presented in Figure 16. PRECIPITATION In nearly any climate, precipitation is probably the most variable parameter measured. Available data shows that annual amounts of pre- cipitation range from 23 inches (584 mm.) at Larsen Bay on the leeward side of Kodiak Island to 121 inches (3073 mm.) at Chignik. Differences are due primarily to variations in terrain and exposure. For instance, Larsen Bay, Cape Sarichef, and Cold Bay are all affected by a terrain obstruction of the general air flow which reduces annual precipitation in those areas. The air that travels ahead of storms generally flows from a south- easterly direction with a long fetch over water. It is heavily laden with moisture and ready to deposit large volumes of precipitation. Based on precipitation measurements taken near sea level, precipitation on ridges and the windward side of mountain ranges will probably reach as high as 200 inches (5080 mm.) in isolated locations. Precipitation in periods of 24 hours or less is excessively heavy from time to time, resulting in local flooding. Watersheds are small, so floods of this type would be of fairly short duration, similar to flash floods. Mean annual values of total precipitation (including water equiv- alent of snow) and snowfall are found in Table 2. Frequency of occur- KITOL BAY, ALASKA LATTIUDE: _=90))' _—_ LONGITUDE: 152021! EVEVACTON: APA OF-) THAVERNTURE (°F) PRECIPLTAITON (CIN_INCHES) . “DAY. | Extremes Snow, Tce Pellets | — é) fA a 2 & 6 2 a a. oO & 2 a B By) 8 ee ge 18 3 ie "s o @ 4 a ov a Bla [8 a |e] ls |88 8 eal a Bala fe als |e 2168/2 [8 [E58 |BS) 2 88) 8 le & 5 | 5 = “Tes | he | 34 49] =L 2066] 9,041 1964/10. 8122.9] 22/1969} 41 * oy _=2] 113.5126.7 38_|1969} 10, 7 5| 54 =3 16.5[45.7| 28_)1956] 11 Bo 671965 |" 9 | 4 21-1956 |-12. 0. | 19 {2 aT 0 | 31 o}. | 35 “0 o] = oO) 27 iz 5 158: [512 1968} 1 12 1969 129 STATION: KODIAK, ALASKA LATITUDE: 57°44N" LONGTTUDE: _152°31°W ELEVATION: hy _[___TEPERATURE (F) PRECIPITATION (IN_INCHES) ee] Means Extremes Snow, Ice Pellets Tenperature Max Min a 8 Ble see ls & 3 BB lela 18 a » 4 a> 8& & 2 |e}, |e 2 £2). So/B S18 |g € 8/8 18 | 8 Bela is lg2la (a Bake, ble, |? 8 lels le] 8 S32 | (88/2 bs ESR BAR Ie - fo | s 20 | - [20 [oo | - [20 | 20_|20120|20_|20] 7 10.16 n9AC M1469 | ip hazy | 10.5! 64019) x: = 4.5 [34 -chaei | 10.0) 15] o}a H7-7.} 74.9956 | 17.8) 15 }o17 | 22) #] 21,9965 | 10,5! JA] OL a H.onges | 4.0 16.].0}*.1..2].0] Tosser 1]0 Jo. OJ C.0) Of uk joyo 0 0.0) isto yo} alo] 0.2] 7 /O}o}_#] of le} 0.41} 10] 0] iz {oO} 4 | 16,0 16 }© ho | 23] #1] LY | 86 10 fio 30d *] (a) Pertod of Record . Less than one half + Also on earller dates, months or years T ‘Trace, an amount too smill to measure Table 2. Detailed Weather Summaries, Western Gulf of Alaska (from Environ- mental Data Service [NOAA]). Note: Mean precipitation data in- cludes the water equivalent of snow. 31 LATTIU ____LONGTUPE: 15 4°08 w ELEVATTON: $y (IN INCHES) ES Extremes Snow, Ice Pellets | 3855 Ko tobs fol fabs S 5 Ky 2 af if § 2 2 » 2 7 3 . : > 8 8 4 g R Be BC 3 8 $2 S)s [8 ls 1s 82 1a | 88] 4 gel y [eo a|o |® |o 2 gd }o | 25/5 Pal o |RE its col a Dt sn oa ~ oO > OL oa > joo 19 4 4 31 6 | 11.2) 4 3 15 3 27 flo. 22 19}1 A.) 9}.19) 2] | 3] Wa) ® a}.1} 4] oJ a) ¥] #lol #1 01..0}.0] *}.0/0} 1] -O1.*| 81.0) O}.2)_ 8) 14 -0}.5] 12 | #4 011 | 18.) _# 3 961.4116! * 149 1126 Is. STATICN: SHEARWATER RAY LATITUDE: 57°21'N LONGTTUDE: 152°55'W. EJEVATION: 10 or iL MPERATURF, (°F) PRECIPITATION (IN_INCHES) Fall tuner ro eens Extremes Snow, Ice Pellets Temperature _| Max Min § a “TT sS 2 ~ 2 $B gh) o z | 3 Bl [Seles fs g Beale a |e . 43 > 1p 86 & ga} 18 Bo) [Bel Z {8 13 |e 8 Sely 2] Gal g foe! [8 | [h : Bele BG] 8 Be Ble ky Ie & B8l8 Bale 8 sles BIS |p 12 t o)i2 he | a2 ha 0 -i2} 0} 8 [eu] o. 4 ao fo} 4} 22.)0 u 9.4) 2610. 1 _ 9.1.0 | *| 20.10. 2] a olo}] Blo] T ola} ato. 7 y}o} 0 }o 33) 9) 8 elo] 4 ee hs 0} 3] 20 017123 9 Bh Gn (a) Period of Record - Years (through 1970) 5 Less than one half + Also on earlier dates, months, or years T Trace, an amcunt too small to measure Table 2, Continued. 32 STATION: SAND POINT, ALASKA LAITIVDE: 95°20" LovGITure: _160°30" ELEVATION: “TEMPERATURE (°F) PRECIPITATION (IN INCHES) ita iT ~ Means Extremes Snow, Ice Pellets ~ z| ledel &| [2 3 BHR aig [2 3 § Ie 7 iB 7 7 18 2) 4/8 |g 4 2 3 2 Ba 18 8] tal glele le 24] é El. |B B27 l_ 188le_ lg [S84 [83] 4 og Else d5/8 (218 12 Bile |B5|8 | | 28 8 esl 2 es 8 less lala lo a] 2 a] 8 jf 6A |S | sLl]S Is 645 [SS] 2 [Ss Ss BLA | 4) A |S [( 4 a a a 44 31.4 [7.6l23_3 [isle | 6 olnoue |i 200.171 2010 31.3 1 8 20}0 | .6| 2110 8. ..16}0 | 10! 26]0 1. iio | *| 18)0 T ilo} o} sjo J 0 Azo }.o}.. "OJ 0 22/1] 0} 0/0 0 iio Q| 1/0] 0 17/0 | of 1/0] T 2110] 0! ~ 3]0 6 13} 0 | 31 19/_ 12 70} 0 8| 710] 1 L947 i 2ogl2 134113610] LATT INDE: 58° 24" ALONGUT IDE; 160° 49" ea PREC IPTTAPION (IN TNH 8 2 : g 8 5 3) |g y a i 8 8 ae aaa Boel ala |e et ly at ot ae te a iE 7 L> gd 8 ig als |% # 16le |B le 82 S55, [8 a H Slols |e | eg peg |e pele lala fo 212) |2 12 sa Say X 1s [olor 1S | well Sale WNBA co 25.5} 55 32.6] 39.0|80 1901| 7.6 3.0 1905447 190s |57.2] 0.01807 | riod of Record through Coal Harbor observations began in 1892 and ended in 1911. S than one half Not all items presented here were continous + Also on carlier dates, months, or years during that period, T Trace, an sinount too small to measure Table 2, Continued. LAITIVDE: 570 32'N__[ONGTIUDE: 1$40 00°" __EURYATTON: 15) - PRECIPITATION (IN INCHES) PY ; i Snow, Icc Pellets Pemperature ~ Wax STATION: iaRs i Greatest Depth cn Precipitation .10 Inches er more Greatest Greatest Monthly Greatest Monthly Ground 196s. 4 1967 |7. ra K,_ALASKA LATTTUDE: 56°18" LONaTTpE: 158023" ELEVA RUE (OF) PRECIPITATION (1 INCHES) = oe Extremes 7 Snow, Ice Pellets rernerature_ Min § 8 a » , g : x 3 B a && b |= & z 3 ne 318 » 3 2 » 2 2 » SE mi Sle] |p 3. 82 Ba 8 3c] Ba Ble £ |g} 8 |s 2a |eele ls | 2a [eal s eee tee a ie Sia} s |e S48 |2 [82/2 |f | 888 |Z] 2 BS 2 Ese ae |e, a9 [9 am “Tt etele te tele le 9404 | =12| * 2.8127.2 11971] 7.0 1928 123 | -19.10.:10)..25) 14 +] 5) WS .2 416.8 131.0 11991126 11929 |32 -154.0.;.11) 23/2 0} £.3118.0 11969) 8.0.11969 luz BY 0.112 - 26} 2 4 4.9 18,2 119721 8 aoa ae oy ; a - : 2. Mu 4 Bad 3:3 1971 1971 22 Ca eite 1 10,0 [ 0. 16 18 [Of e6 9.0] 0 137) 0) FI : 0.0] 0 20.|* 1 3.8h2.0° 15|0- | 4,9 | 16 | 9,8 bs 5 | 15 |0. [158.5 Biro. a72 la (a) Period of Record * Tess than one half (0.5) + Also on carlier dates, months, or years T ‘Trace, an amount too small to measure Table 2, Continued. LATTUDE: _57°34'N TONGTIUDE: _156°0 2d PRECIPITATICN CIN_INCHES) Snow, Ice Pellets ners 4 ~— vax Min g| 8 B £ 5 3 5. 5 = hi & 3 a . | » 2 2 » 2 8 a 2 |p 3 oe 84 3 3a B ~ fa] é |g $a )8 [88/8 |e | 88 8 18S] & Be] 8 iB 8 da] 2 |e &a | |S8|8 [8 | 8s 2 iba] 2 BS 8 lk & | _ cam \——4 20.2] 2u.ales a2 3 34M} 37.9} 50) |_5. 0 51 ugl_2 | 34 2t 0 | 1 9 5 | 16. 0. 0) a 2.06 “ut 0. a 6 10.19'1949! 0. 7 65 — ~6.02-1G9| 0. oO} 2 1940 “te a are 2. y 3 | | 2 491] 1] [75 2. 8 b. & : 8 $4 wey un ee i Or Period of Record (b) Climatolopfen] standard nomanls (1931-1960) than one half carlier dates, months, or 3 Table 2, Continued. 35 __ LATITUDE: 4° 36'N_ ___LOnaTrupe:, 164° 56'W PRECIPITATION n 2 3 B és 2 af 3 fg E 8 8 : 5 a 2 16 ie 28 vie] ? (a) Period of Reccrd * Tess than one half + Also on carlier dates, months, or years ic ‘Trace, an amount too small to measure Table 2, Continued. tetocoioo'a tooo # 32? Oooo tA NOD 36 59 50 0.2 0.1 0.05 0.5 of Temperature Range Ten years of data (from Air Weather Service, U.S.A.F.). Temperature Distribution, Kodiak. Figure 15. 38 F 9 50 23 14 5 4 of Temperature Range. Twenty seven years of record (from Air Weather Cold Bay, Temperature Distribution, Service, U.S.A.F.). Figure 15, Continued. 0.2 0.1 0.05 0.5 50, 40 30 20 10 40 30 20 10 0.2 0.5 0.05 0.1 Twenty-seven years of record (from Air Weather Figure 15, Continued. Temperature Distribution, Cold Bay. Service, U.S.A.F.). 39 aN “AUGUST Figure 16. AIR - SEA TEMPERATURE DIFFEREN Sea Temperature (degrees F) and Air-Sea Temperature Difference, North Pacific and Bering Sea. Twenty years of record (from Navy Hydrographic Office 1961). way OVEMBER OV 41 rence of specified monthly amounts of snow, daily amounts of snow, and total precipitation are shown in Tables 3 and 4. The frequency of occurrence of different types of precipitation is shown in Table 5. Data in the last three tables are for Kodiak and Cold Bay only. SURFACE WINDS Wind data for four locations (Kodiak, Cold Bay, Cape Sarichef, and Sand Point) are found in Table 6. All four stations show ave- rage wind speeds well in excess of those found at interior land stations. Wind speeds at Cold Bay and Cape Sarichef are appreciably higher than those at Kodiak and Sand Point. All four stations reflect terrain influences on wind direction and speed. This limits the usefulness of these wind data for planning at other sites. Sustained extreme speeds at the reporting stations range from 50 to 75 knots, gusting as high as 100 knots (Table 6). Wind speeds over water are stronger due to less surface friction, and in the event of an unusually intense storm, a sustained wind of approximately 100 knots is possible (Thom 1968). Revisions of original charts pre- sented by Thom (1968) show a recurrence of 100 knot winds once in 25 years and 80 knot winds once in two years along the Alaska Peninsula. These data are based on wind measurement onshore and from ships far offshore in the Pacific. Considering the frequency and intensity of storms just offshore the Alaska Peninsula, an average of one sustained 100 knot wind may occur over open water annually. ! Occasionally, winter storms are slow moving or nearly stationary. Such conditions produce a persistent wind direction, creating sub- stantial wave action that could affect coastal or offshore installations. Average wind directions can be estimated from Figure 11, which shows surface and upper air patterns. The scale of these charts pre- cludes their use in estimating wind speeds. More detailed information on wind direction and speed is available upon request from the National Weather Service. VISIBILITY Table 4 presents the frequency of occurrence and cause of visi- bility values of less than one mile. Table 5 presents the frequency of occurrence of different weather conditions as obstructions to vision. Anything in the air that reduces visibility to six miles (9.6 km.) or less is recorded as an obstruction to vision. Detailed average visibility conditions for Cold Bay and Kodiak are shown in 1 - H.W. Searby, Climatologist, Arctic Environmental Information and Data Center, University of Alaska, Personal communication. 42 VISIBILITY SKY COVER @ PERCENTAGE FREQUENCY PERCENTAGE FREQUENCY] 5 =. OF OCCURRENCE OF SKY a Hourly Obsns/w COVER (BASED ON HRLY |, A | ee <1 mi., caused by: WS) S > | Sal ||/----= ect CATEGORIE 6 ee] Fe Eg fe TENTHS OF TOTAL SKY [Ou B21 08 S2s)y | an COVER Ba o sw © wf] Oo) ao o}AnIS Ov os go o 8 9 9 FISH ee 2S) OIF Ee] a> é @ a: | oN} 2 8) 32 ep] e}] ar] e © © of om » 1c] 9S S| sa even] 3 i { A 1 off. A Bn am we 8 OE ela] Se Sloslaglas| Of ° x © © a la8 [_ SNOWLALL MONTHLY VALUTS DoLOw AKL PER= CENTAGL FREQUENCY OP OCCURRENCE g§ g ¢ p——__OF DAILY AMOUNTS >| ¥ £ CATEGORIES BELOW ARE IN INGHES @ £8) a5 a “ pe ER] >o |} INCHES > PB a ge ge)a. Be A & ee as N En. om S Batos Se o g 2 iB pe) 28 IL. $a8 8 25% z , (fs Eeleelee sag 24) jad s 3 o a o S& a aA oo o 38 AUInG S828 [BS ESS 8 a [ee 2a: * }10.5 19.9) 12 17 288 17 10 12 8 2.54 17 2.49 0 9.6 23.4] 12 12 31.8 16 10 12 9 2.62 16 2.49 * 19.9 17.6] 12 14 33-8 2110 9 6 1,82 17 3.89 0.41 1.34 A 38 38 12 10 1 * * * 0 | 5.9 44.7] 7 16 42615 9 8 3 1.56 13 3.83 0.02 1.76 M73 20 5 2 1 0 00.0 1.1 9,3] 2 14 367 16 9 10 9 2.15 15 6.37 0.62 2.22 199 1 * 0 0 0 0 0 0 T O.S| «* 15 388 14 6 14 6 2.19 14 6.98 0.12 2.10 3100 0 0 0 0 0 0 0 0 0 0.0} o 13.338 16 9 11 9 2.24 16 4.63 0.28 1.74 A100 * 0 0 0 0 0 0 0 T 0.0] 0 8 297 18 10 13 15 3.89 20 9.97 1.40 2.17 S98 2 * 0 0 0 0 0 0 T 0.2] * 11 23:7 19 10 17 14 3.81 20 9.79 0.91 3.43 O63 24 7 5 1 * 0 0 0 | 2.5 15.6} 4 7 22.5 19 13 20 13 {4.34 22 8.02 1.88 4.90 N43 31 12 11 2 1 * 1 * | 6.4 21.6] 9 13 20 5 18 12 16 17 {4.27 20 8.94 1.46 3.43 D28 34 17 13 5 2 1 * * 410.4 20.3] 12 12 31819 9 14 9 2.88 18 6.49 0.19 1.94 Yr61 20 9 7 2 1 * * * |55.4 23.4] 69 13.30 7 17 10 13 10 [34.31 208 9.97 0.02 4.90 * means less than one half COLD BAY Table 3. Detailed Weather Conditions, Cold Bay. Twenty years of record (from Air Weather Service, U.S.A.F.). I 43 SNOW DEPTH __ VISIBILITY. SKY COVER _ in Tenths [| MONTHLY VALUES BELOW ARE PERGENT- ‘— || PERCENTAGE FREQUENCY PERCENTAGE FREQUENCY] AGE FR s |=, || __ OF OCCURRENCE ___ OF OCCURRENCE OF SKY (BAS: & | 27 || Wourly Obsns/v Vsby COVER (BASED ON HRLY | a {ee <1mi., caused by: ___-- OBSERVATIONS) g =| Bal ae wt CATEGORI 6 83] es SLES ce TENTHS OF TOTAL Sky |O on ola Qa EI B Ble 8 zs 9fee22 enlSsla.| OV Coven tg S| 5 & et god fess) slessesigel se i ole] altel elg S14 & w eel = a slefl|ge Bl abagisg | 8s eo] eo] eo] H]a J j29}15 | 23} 8} 7] @| 614] o} of 2.217.3 Ili.s} o | .6 }1.6] 3.7 |! 30.5) 6.5 | 6.4 | _F_}34 | g9}|*} o| o 0 | 4 fis} 3 6.0 z 31) 2 0 3 6. 27 | 0 0 1 0 0 0 1 9 0] 0 Table 4. Detailed Weather Conditions, Kodiak. Weather Service U.S.A.F.). MONTHLY VALI: meee | : BELOW Ait m Oe CENTAGE FREQUT a PERCENTAGE FREQUENCY OF § 3 2 FE, | OCGURKENGE OF DAILY AMT3,| = 2 > x § a8 GC. ORILS BELOW vw & w 2 § s° AR IN INCHES Bo BU § go os £ Ss [An se 2 2 & S. €£. | 6. Si 6° 2 UE / S Pers ee [2s ag [23 g228 |S82y 2 8 3B BB Be Pi Me Pre TE ND Poni ear ene Sipe ites Staab ay. cm pier tescppe se eb esetae tebe Bean vo = = 2 a a § § Bt VReee ey [8S a2 lSS iiss es sasan 8888 5 & 38 2 4 8 © GHA wo BG 26 20 |/22 6 2 2a 3a 2 a 2 J 47 26 5 10 6 2 1 1 1 4|i4.9 40.1 | 8.2]]y 26 18 4 6 8 17 21 [4.93 16 10.16 .24 3.20 F 44 28 6 11 5 3 1 1 O [14,5 34.0] 7.8]/|F 28 20 2 8 7 15 20 |3.91 15 9.61 1.41 1.41 M 38 29 7 11 7 2 21 2 3 (117.7 74.5°| 10.3]}M25 25 2 10 7 16 15 |4.01 15 8.12 .89 1.78 A 59 21 7 8 3 2 1 * O | 7.0 21.9] 6.1]}A 31 21 4 8 12 16 {3.22 14 4.98 1.13 1.70 M 95 5 0 0 0 00 0 0 -4 4.0 | 0 M27 16 4 8 8 1819 |4.05 16 9.53 1.00 1.87 J 100 0 0 00 00 00 T OT 0 |/s 38 19 2 11 6 11 13 [4.05 15 11.78 1.42 2.31 J 100 0 0 0 0 0 0 0 0 J{ 0.0 0.0} 0 |]s 34 17 4 10 5 13 17 |3.60 14 8.09 1.01 2.46 A 100 0 0 0 0 0 0 0 0 J 0.0 0.0} 0 |JA34 19 3 811 12 13 |4.67 15 9.30 1.68 2.23 s 98 2 * 00 00 00 T 0.2] 1 |/s 31 19 3.21 7 11 18 [6.11 17 12.60 1.80 2.64 Oo 77:18 1 20 * * 4. * 2.6 14.9 | 1.6)/025 23 1 10 6 14 21 {5.32 16 10.57 1.56 2.47 N 60 30 2 4 2 1 1 * * 5.0 24.3 | 3.0/|N21 19 3 7 8 14 28 |5.51 17 10.28 0.19 2.34 Dp 37 36 7 9 3 3 2 1 2 412.7 28.2] 8.2//p21 17 2 9 5 14 22 [4.84 16 9.60 1.78 2.03 Yr 71 16 3 5S 2 1 21 * 1 [74.8 74.5 | 45.4]|¥r28 20 3 9 7 14 19 4.42 18612.60 0.19 3.20 | * means less than one half KODIAK Ten years of record (from Air 'Y OF OCCURRENCE OF WEATHER CONDITIONS AS OBSTRUCTIONS TO VISION nnd ai 3% OBSERVATIONS | SMOKE, [# OBSERVATIONS FREEZING 'SNOW AND, WITH FOG |AND/OR |BLOWINGw/OBSTRUCTION; [OR SLEET | PRECIPITATION {HAZE _| SNOW _|TO VISION > é T > > is > Sailiiitt aloy| @ v iv | 3] vu] g@] ul a] v a a/ 8/8) 8] 3 8/3) /alalal a | 2 | Oo} 6] 30 } Ol oo} O] of S| 6! O!1 oO 8 ° % oO x ° | O| “| Of 1 0 M oO iesul — aj} 2.4[3.7| 11.1) 21.1 iin ON . T | 7 o|1.4|7.3| 9.7! 19.1 | i +1 [2.9/6.3 8.3] 17.0 - 0 4 a 6.6! 12.7 12.21 12.0 16.5! 18.0 12.9! 32.4 10.5) 18.0 +2} 6.3] 9.5 0 0 0 17.5] 28.3 4 0 0 o | .1 [1.2] 3.0 9.3] 13.4 0 O {2.67.4 6.7) | 17.6 1 DM Ae : 2910-8) 18.4 | 7.2| 13.1) 31.0 | 34.0 9 15.5] 22.1) 30. Table 5. Percentage Frequency of Occurrence of Weather Conditions, Kodiak, 10 years of record, and Cold Bay, 27 years of re- cord (from Air Weather Service, U.S.A.F.). WIND DATA PERGENTAGE FREQUENCY OF OCCURRENCE Avg Peak |Direction> 30- T20> ]150> J 1802 210~ | 240= | 270= 7 300=[ S30= va Poak] Wind Gust {Month 60-90 | 120 150 | 180 | 230| 240 | 270} 300] 330 | 360 wind Gust nie Jan 5.23 [10.59 | 5.77 ]10.91| 4.78 |1.64 | 5.06 | 6.86 | 25.86 | 18.44 12.9 64 4reb 12.53 | 13.50 } 10.95 | 8.12] 4.51 |4.74 | 4.68 | 6.54] 24.61] 8.91 10.7 Mar 11.54 [14.16 | 8.44 | 6.38] 3.74 |2.95 [5.87 | 8.66 | 23.58] 8.30 [11.5 57 _|Apr__ | 7.77 |_ 7.38 | §.82 | 1.11] 5.01 [5.91 |7.15 112.26 | 22.92 | 7.94 19.61 [13,10 | 6.87 | 5.73 | 2.18 [2.39 [3.31 | 5.40 | 18.83 | 13.51 18.87 [10.71 | 11.60 8.28 | 3.29 13.28 | 4.23 5.05 | 14.22 | 12.54 2.1 35 Jul 1,81 | 1.86 J11.19 [11.69 | 5.73 | 9.75 | 5.81 |5.00 |7.60 |14.08 | 13.97 | 9.57 9.0 49 |Aug 1.17 | 2.42 8.26 | 7.84 7.69 {10,82 | 2.95 |4.14 |7.66 |17.59 | 20.27 8.06 }10.3 56 9.3.56 Sep 1.98 [3.36 |12.84 | 9.80 | 6.47 | 4.24 | 2.43 |3.25 |5.91 [16.93 | 24.38 | 7.91 10.8 64 10.7 51 _lJoct_[2.17 | 2.60 |11.21 |10.66 | 5.21 | 6.07 | 2.30 |2.91 |4.70 |16.20 | 26.79 | 7.64 |12.3 59 12,0 59 ||Nov_.28 [2.81 [11.75 [13.72 | 7.45 | 9.22| 5.07 |4.64 |7.67 |13.61 |17.69 | 4.88 ]13.8 68 12.6 55 |lDec_.o6 |3.50 |16.29 [15.68 | 5.11 | 7.58|3.45 [2.99 [4.50 [10.15 | 22.05 | 9.58 ]14.5 63 ‘Above Above Calculated |¥R__h.89 |2.93 |12.26 111.57 | 6.39 | 7.35 |3.79 |3.65 |5.70 | 9.86 |21.26| 9.77 I calculated in Knots AVERAGE WINID SPEEI} in MPH kwors}6.0|7.8 |10.5 | 9.4 | 9.4 |9.4 |7.9 |7.5 | 8.9 J10.3 Jaro | 9.2 mpi] 7.0 }9.0 [12.1 |10.4 }10.9 {10.9 |9.1 |8.6 [10.2 J11.8 |12.7 | 10.5 T Table 6. Wind Speed and Direction, Sand Point. Four years of record (U.S. Army Corps of Engineers, unpublished). WIND DIRECTION WIND SPEED PERCENTAGE FREQUENCY OF OCCURRENCE MEAN VALUES, SHOWN IN KNOTS IF M A M Jj J _A_ 8 O° N D A Moy 1A s ° N D ISSE_ SSW sw jwSW] NNW INW ‘alm| 2.6 2.7 2.9 2.6 3.8 2.6 2.1 4.7 8.4 2.7 3.8 2.7 3.6 3.2 4.2 2.9 3.3 2.7 2.7 2.2 8.6 2.9 4.5 5.5 4.6 4.6 10.3 9.3 3.8 7.9 7.2 6.6 12.5 12.4 4.1 5.9 4.5 3.8 2.4 2.0 1.5 8.2 8.8 8.7 4.3 4.2 3.1 2.9 1.4 5.8 6.4 7. 3. 2. eo &©b aN 2. 1.0 5.7 8.5 7.3 12.6 6.9 8.3 4.1 2.9 2.5 2.0 1.2 3.7 2.8 6.7 5.4 8.7 5.2 6.6 3.7 3.8 3.2 3.5 1.6 7.3 LS 4.0 4.2 6.0 4.8 6.7 4.6 S.1 4.1 4.3 3.1 10.2 13.1 15,8 16.4 12.0 24.3 21.7 24.3 22.7 6.1 8.9 8.6 6.9 6.8 3.6 7.2 5.6 4.5 6.0 4.9 7.5 9.0 10.9 14.4 13.9 15.9 18.2 3.1 4.3 3.5 5.1 5.2 4.8 7.9 7.6 10.3 7.5 2.5 2.0 3.3 3.4 3.8 3.5 5.3 3.6 3.5 3.6 4.6 3.7 12.3 12.8 22.1 4.7 5.3 2.3 2.7 3.7 2.3 3.4 3.6 5.4 5.5 S.1 4.9 4.6 2.5 7.2 12.4 22.0 5.0 7.4 2.5 6.8 17.2 27.2 5.0 8.2 9.3 9.3 14.5 15.3 15.3 14.2 13.1 13.2 11.8 6.5 5.7 5.2 5.9 8.4 12.5 12.7 {0.8 14, 1 12,1 13.3 13.9 10.7 11.1 11.0 8.7 5.2 6.5 5.7 6.7 8.2 14.2 12.5 10.7 10.0 9.7 13.0 12.6 12.8 12.6 11.8 10.1 9.9 6.6 5.9 5.0 7.3 8.9 14.9 11.8 11.7 10.6 9.3 8.6 7.1 5.6 6.6 6.3 9.3 9.5 12.7 11.5 10.7 12.0 10.3 8.4 9.6 9.3 10.9 7.21 6.5 4.8 7.5 10.7 11.0 10.6 9.2 9.3 11.1 9.4 8. 9. 10. 8. NY 2 0 m@ mH B® & © 2@rnaunan a nn oa 8.5 6.9 6.0 6.5 7.6 8.2 5.9 5.9 5.6 5.4 6.5 8.5 9.6 8.7 7.6 6.8 6.4 5.3 6.2 6.9 7.2 5.8 5.9 S.1 3.9 4.3 6.2 7.4 7.2 8.1 7.2 6.1 5.6 6.1 6.1 7.9 5.9 6.9 5.5 5.3 6.7 8.2 8.7 8.0 8.1 8.9 7.5 7.1 9.4 8.8 9.5 7.2 7.8 6.0 6.2 7.6 14,9 12.9 12.3 10.9 12.4 12.0 9.3 7.3 6.9 6.2 6.2 8.7 8.2 11.5 8.9 10.8 7.7 10.6 Monthly Average Speeds 8.6 7.1 S$.9 6.3 7.4 9.7 14.2 14.0 17.1 14.9 16.1 13.8 11.7 7.3 6.9 5.6 7.4 7.5 13.2 12.6 12.0 10,7 8.4 14.4 13.3 14.5 13.8 13.7 12.5 10.5 7.6 5.6 5.4 6.4 7.2 13.8 12.9 9.8 10.7 Table 6, Continued. Wind Speed and Direction, Kodiak, Weather Service, U.S.A.F.). 10 years of record (from Air ov | WIND DIRECTION WIND SPEED { i PERCENTAGE FREQUENCY OF OCCURRENCE MEAN VALUES, SHOWN IN KNOTS | i tT, F M A M J J A s oO N D J F M A M J J A Ss ° N D N 6.9 10.4 9.4 7.4 S.1 3.5 3.1 2.6 4.5 5.3.7.9 10.3]14.0 15.2 14.7 14.0 11.6 9.7 8.4 9.2 11.3 13.7 14.0 15.2 S.7 7.1 5.3 4.1 3.0 2.0 1.6 1.7 3.0 3.0 4.8 6.8]17.7 15.9 16.7 13.3 11.5 8.6 6.6 8.7 12.3 14.8 15.2 18.1 NE 1.6 1.7 1.5 1.5 2.0 1.2 1.4 0.8 0.9 1.4.2.5 1.7]12.6 11.9 9.3 8.2 9.1 6.8 5.5 5.9 9.0 10.3 15.2 12.4 1.5 1.0 0.8 1.3 1.9 1.4 0.8 0.9 1.0 0.7 1.1 1,0]17.6 13.0 9.6 11.1 11.2 13.0 6.9 8.2 14.7 11.9 13.9 13.7 —_——— E 2.1 1.8 1.2 1.4 2.7 2.0 1.3 1.1 1.1 1.0 1.6 1.7]19.1 16.2 11.3 13.9 13.5 14.8 10.2 10.1 10.8 12.2 15.5 17.3 ESE S.2 4.6 3.7 3.5 6.0 6.1 4.4 4.9 3.4 3.0 3.5 3.4]20.4 18.9 21.1 18.4 17.6 18.2 19.2 17.3 16.2 16.5 16.6 18.7 | sz 12.7 12.6 10.6 11.4 15.8 16.5 14.1 15.5 10.7 7.8 9.0 7.7]20.4 20.6 19.6 18.7 18.1 18.0 16.7 18.5 15.9 17.5 18.0 17.6 BSE ]15.5 15.3 13.5 12.4 15.3 18.4 18.1 15.5 15.3 9.1 11.8 11.7]19.3 20.2 19.5 19.4 18.5 18.0 17.7 18.8 17.5 18.5 18.5 19.3) s 4.7 4.6 3. +5 5.4 2.8 2.8 2.6 3.2 3.2 4.9 4.4/14.3 16.1 15.3 17.1 14.6 13.1 12.7 14.5 13.5 13.5 13.6 13.7| & @ Bsw 1.51.9 1.4 1.1 1.4 0.4 0.3 0.6 0.9 1.4 1.7 1.6]10.7 15,1 14.2 12.9 12.1 6.7 8.2 10.3 7.0 9.7 10.6 10.6 sw 1.9 2.5 2.5 1.4 1.7 0.9 1.2 1.6 2.4 3.7 3.4 2.9]11.9 15.9 15.7 11.0 12.1 11.8 13.7 11.0 10.8 11.7 11.1 12.7 VSW] S.2 4.8 5.7 4.2 3.7 3.5 5.5 11.3 3.5 12.0 8.3 6.8/16.0 15.6 18.7 16.3 13.4 14.3 15.1 16.2 14.3 16.2 15.6 15.6 Ww 4.3 4.1 5.1 7.2 6.4 7.6 12.9 14.4 10.6 9.7 6.4 5.7]12.3 13.0 14.6 14,5 13.2 12.7 13.3 13.5 13.4 14.9 14.4 12.6 WNW} 6.0 5.9 7.1 11.0 9.4 13.5 14.0 13.4 11.8 10.5 7.8 7.6]11.8 11.6 13.8 14.2 12.4 11.5 11.2 12.3 13.1 14.6 13.3 11.4 NW] 8.1 7.6 9.9 12.6 8.6 10.5 8.7 5.8 9.4 11.5 8.9 8.4]14.4 13.6 15.8 14,7 12.3 10.7 10.3 10.7 14.2 15.9 14.7 14.2 NNW} 12.3 10.1 14.2 12.2 7.4 6.0 5.1 3.3 8.5 11.9 11.7 13.1]16.3 14.7 15.2 15.1 13.5 10.8 9.7 9.7 13.9 17.6 17.6 15.6 alm! 5.0 4.2 4.1 3.8 4.4 3.8 4.7 3.9 3.7 4.7 4.8 5.1 Monthly Average Speeds | 15.7 15.8 15.8 15.1 14.1 13.7 13,1 14.2 13.8 14.9 14.9 14.8 — Table 6, Continued. Wind Speed and Direction, Cold Bay. Twenty seven years of record (from Air Weather Service, U.S.A.F.). Lv WIND _ DIRECTION I WIND SPEED \ PERCENTAGE FREQUENCY OF OCCURRENCE MEAN VALUES, SHOWN IN KNOTS : I F M A M a J A s oO ND I F M A M vs I A s oO N D 4.7 4.6 8.1 7.8 4.0 5.2 3.2 2.0 3.4 “4.0 5.4 7,016.0 11.3 14.7 11.9 9.5 7.7 6.9 6.0 12.4 13.0 18.9 14.5 INNE [0.6 10.2 7.4 14.8 10.3 14.9 12.4 4.1 9.7 7.0 8.1 12.017.5 16.0 12.2 13.3 11.5 8.5 9.1 7.1 13.1 13.5 17.6 17.5 NE R0.7 13.7 5.4 2.4 3.2 4.4 3.3 5.4 4.9 4.2 16.1 14.2]18.2 18.4 13.6 10.2 10.6 8.1 7.4 9.9 13.7 15.8 18.2 14.8 pNE pO.7 9.1 3.9 3.0 2.9 1.6 1.9 2.0 2.1 4.0 7.4 7.3]12.4 14.8 9.7 12.3 12.3 8.0 11.2 11.2 10.0 11.6 14.6 12.0 { BE j1.0 3.8 4.9 2.4 1.3 0.4 0.6 0.7 1.1 1.0 1,8 3.2] 8.4 20.2 15.1 17.7 8.3 6.0 12.0 9.1 10.8 15.0 9.0 8.8 feSe 7.1 6.1 2.6 3.3 3.6 2.3 1.3 1.0 2.4 2.9 4.9 6.0125.0 16.7 18.4 19.1 18.1 10.5 7.8 17.5 14.6 14.1 13.3 12.9 | sp 3.6 5.6 7.6 2.3 4.9 2.2 0.9 2.6 6.0 3.0 5.1 2,812.9 17.2 18.7 15.6 17.8 19.3 17.1 12.9 24.4 13.4 13.6 12.0 SSE 11.8 17.4 17.1 13.7 16.3 11.7 19.2 18.0 22.0 8.3 13,0 12.9]14.9 16.6 20.0 17.4 16.1 16.4 17.5 16.6 18.6 16.4 17.1 14.3 S$ {3.8 2.7 4.8 4.9 4.5 4.9 5.0 6.7 4.0 2.6 3,0 2,213.1 15.6 14.8 16.3 19.0 14.0 13.6 8.3 14.1 10.4 13.1 13.9 SSW 14.7 5.6 3.1 5.6 11.2 10.8 18.8 21.5 9.7 4.9 6.8 3.4715.7 13.3 12.1 12.5 12.5 6.4 9.2 9.9 9.7 13.6 13.9 13.0 SW {3.7 6.9 5.6 7.2 9.5 9.1 7.9 9.3 7.2 4.6 5.5 3,617.5 15.7 13.9 17.5 10.9 11.1 8.5 10.8 17.5 18.0 18.5 13.7 SW] 2.4 S.2 5.0 5.9 6.5 10.3 7.9 7.6 5.5 11.7 5.6 3.9]19.5 15.3 16.8 15.0 13.3 11.9 8 9.8 10.5 19.6 13.7 14.7 | W/2.4 3.7 7.2 4.8 5.9 4.4 2.3 6.0 2.9 5.9 2.7 3,010.8 13.2 12.8 9.1 8.8 6.8 4.5 8.0 9.4 13.8 10.5 9.5 brs 2.7, 1.3 7.1 6.7 4.1 5.5 4.1 2.0 6.2 13.3 4.7 5,418.0 15.4 15.3 13.0 11.9 7.3 9.2 8.2 11.9 16.7 13.2 16.9 INW }6.8 2.0 5.3 3.6 5.8 3.0 3.0 4.6 5.1 12.6 4.9 6,220.2 11.5 15.8 10.1 7.9 6.9 6.3 11.5 11.4 14.3 13.0 19.3 INNW} 1.6 2.2 3.9 8.9 4.2 7.2 2.7 5.0 6.4 9.2 4.4 5.6#14.0 15,1 14.4 14.1 11.0 8.5 6.1 8.6 12.4 13.7 10.1 16.7 alm) 1.6 0.8 1.9 2.7 1.8 2.1 5.5 1.5 1.5 0.7 0.6 1.3 Monthly Average Speeds t i 16.5 15.8 15.2 13.9 12.6 9.9 10.1 10.8 14.8 15.3 15.6 14.5 Table 6, Continued. Wind Speed and Direction, Cape Sarichef. (from Air Weather Service, U.S.A.F.). Four years of record 8Y 49 a 5 CAPE SARICHEF WIND DATA [| PERCENTAGE FREQUENCY FASTEST [HIGHEST F JRBENC: | MILE | Lr Grouns (Knots! slo ras Se | ee ee a § x ajo |S] o |g] Oo] 3 3 slo] = : i i 2} 8} ge] 8 =] Of vf ¢ Sia {ss} 4] a] 8 a] 2 + Oj a) 8} a) -§ | 3,3130,5 | 47,4 | 12,0 14.7] 0.5 |ESE | 52 46.0 | 30,11 48.81 9.0 14.5118 | E 153 o | s.8136.0142,.6! 8.3 15.0] 0.4 |sE A 2.7 | 6.7} 41.1] 39.1} 6.8 |3.1]0.5 | $_| 52 {M 1.8 | 7.6} 46.4 | 36.0] 6.4 |1.6]0.2 |SE_| 64 b 12.1 |14.5 [54.7 | 25.0 | 2.4 |1.1| 0.3 [ESE | 58 | NNE| 74 Y | TT His.s |r4.atsis|24.4| 3.2 [o.7] 0 A ix.s [13.2 | 53.5 | 26.5 | 4.1 [0.9 | 0.3 [ese | ss is |u.s | 7.2] 41.8/38.7] 5.7/5.1] 0 2 io.7 | 4.7] 36.0 | 44.5 | 9.0 |4.2| 0.2 [ese | 50 nN 9.6 | 6.1| 33.8 | 44.0 | 10.6 [4.5 | 0.4 | ESE | 54 lis | 5.4| 41.9} 38.6] 9.0 |4.3] 0.1] sw| 54 ke 1.3 | 8.1 | 41.8 | 37.6 | 7.1 /3.3/0.3 | SE | 64 Note: Data not available where entries are omitted. WIND DATA KODIAK FRE ‘ASTEST| HIGHTS' |_| Gust Direction! G 3 = Zz = SiN m |o { 2 E §.3/15 8) 42,0/29.9]4 6/2. INW_172114.7|3.6)26.842,7/13.817, 8) = IWNW/46 |WNW1| 7444.8 | 4.2129. 338.4113.2/ 9.1 8.24 .0)34.1/33.1|7.6|2.8| .2|Nw |S9INW {7615.1 a.9b9. tbo, 13.3/ 8.8 YR{7-5[17.9/4 1.3 |27,5]4.2]1.6] * |NW she 9914.4 /3.6 ne 2.4 2917.4 * less than .05 S| ° N |7.4h4.1135.4(32.0|7.513. D Table 6, Continued. Wind Speed for Cape Sarichef, Kodiak and Cold Bay (from Air Weather Service,U.S.A.F.). 50 Table 7. The table also shows visibility in relation to specific values of ceiling height. In general, visibility is better at Kodiak than at Cold Bay. Fog is the principal cause of reduced visibility in this area. It is most persistent and obstructive from June through September, when the air contains the most moisture and is warmer than the ocean. Heavy fog, fog that reduces visibility to one-fourth mile (0.4 km.0 or less, occurs at Cold Bay on the average of five days in June (Environmental Data Service). Other conditions that obstruct visibility are rain, drizzle, freezing rain, snow sleet, smoke, and blowing snow. Visibility charts for the North Pacific are available (Navy Hydrographic Office 1961) but not presented here since the data are estimates due to a lack of visible reference points. SKY COVER Sky cover is significantly more extensive over the western portion of the study area. On the average through the year, 85 percent of the sky over Cold Bay is obscured by clouds, and it is completely overcast more than half the time. At Kodiak, 70 percent of the sky is obscured by clouds, and it is completely overcast less than half the time (Table 4). Ceiling heights--the height of the cloud bases when six tenths or more of the sky is obscured by clouds--at Kodiak and Cold Bay are shown in Table 7. This information is useful to avia- tion planners because it gives the percentage frequency of occurrence of airfield ceiling and visibility conditions. SOLAR RADIATION The source of all heat on earth is radiation from the sun. The amount of radiation reaching the earth depends on major factors such as water vapor, clouds (minute liquid droplets), and latitude. Gen- erally, areas situated at higher latitudes receive correspondingly less radiation from the sun. A comparison was made between data available from Cold Bay (McRoy 1970) and Palmer (Branton et al. 1972) for a seven-year period, 1964 through 1970. Data from both stations are presented in Langleys (a unit of energy, defined as one gram-calorie per square centimeter). The average annual number of Langleys for the seven-year period for Cold Bay is 58,353; for Palmer, 76,983. Obviously, all conditions other than latitude are not equal at the two locales; the lesser amount of Langleys at Cold Bay is due to extensive cloud cover. Since cloudiness tends to diminish from west to east, the average annual amount of radiation should show a slow trend toward higher values from west to east. CEILING dys d SOM ce UOT "Yo 6o.T 89.8 ne 94.5°| 95.0 = 500 95.6 = 400 96.2 = 300 96.5 = 200 | 96.6 = 100 96.6 l= 0 96.6 CPILING e 3 fers |e. lesv)ei2Je14]20 —VISIBILIWY - | = 1800 61.9 [62.8 ]63.0 [63.0 | 63.1) $2 T2007 T6.9° 176.9 [77.4 [77.6 | 77.7 6 1500 A 70.3 | 73.6 |71,8 }71.9 72.0| 7 7 8 & 88.41 88.6) | 90.6] 90.9 93.3] 93.7, “95.7 | 96.3 97.0| 97.7 OTT SUG 4 98.1] 99.1 | ORS, OOS] 98.3] 99.3 Ses Blo Ole Slo als = SOS SIS wlo SN [78.2 | 78.2 : 86.5, 91.3 109.0 COLI BAY Due to the cumulative nature of this presentation, it is possible to determine the Percentage frequency of occur- rence for any given limit of ceiling or visibility separately, or in combination of ceiling and visibility. The to- tals progress to the right and downward. Ceiling may be determined indevendently by referring to totals in the extreme right hand column. Also, visibility may be determined independently by reference to the horizontal row of totals at the bottom of the page. The percentage frequency for which the station was meeting or exceeding any given set of minima may be determined from the figure at the intersection of the appropriate ceiling column and visibility row. . Table 7. Ceiling and/or Visibility, Kodiak and Cold Bay. Ten and 27 years (from Air Weather Service, U.S.A.F.). 51 52 IMMERSION HYPOTHERMIA Hypothermia is defined as a subnormal body temperature (Navy Hydrographic Office 1961). Immersion hypothermia involves a loss of body heat to the water. Generally, a person will die if his normal rectal temperature (approximately 99.6 degrees F, 37.6 degrees C) drops below 78.6 degrees F (25.9 degrees C). Approximate human survival time in the sea directly relates to sea surface temperatures. Immersion hypothermia showing approximate survival time is depicted in Figure 17 (Navy Hydrographic Office 1961). These survival times, however, must be viewed as broad estimates, because data records do not incorporate many uncontrollable physio- logical variables. For example, neither quantitative appraisal nor records have been made of such intangible factors as the physical condition of the immersed individual or of his will to survive. Table 8 relates water temperature to approximate survival time of humans immersed in the sea. Survival time also may be affected by general physique, body position in the water, and amount of subcut- aneous fat. There are two principal schools of thought with regard to survival techniques to use during immersion: (1) Vigorous exercise and (2) pas- sive waiting. Vigorous exercise may dissipate heat reserves more rapidly, although within reasonable time limits, it may keep muscles warm and prevent them from stiffening. During passive waiting, shivering maintains heat production for as long as the rectal temp- erature remains between 95.0 and 99.6 degrees F (35 and 37.6 degrees C). Passive waiting is currently somewhat favored. LENGTH OF DAYLIGHT The total hours of daylight from sunrise to sunset varies with the latitude of a location; the higher the latitude, the greater the range between the longest and shortest days. Table 9 gives figures for two locations within the study area (Cold Bay and Kodiak), and for Homer, which is just north of the eastern end of the study area (Naval Observatory 1959). @ IMMERSION HYPOTHERMIA HIM 5/10 ICE LIMIT LEGEND j——————-_ MEAN MONTHLY ISOTHERM OF SURFACE WATER (°F.) APPROXIMATE RANGE OF TIME A MAN IN ORDINARY CLOTHES} AND LIFE PRESERVER CAN BE EXPECTED TO WITHSTAND IMMERSION HYPOTHERMIA WITHOUT FATAL RESULTS LLL <15 70 45 MINUTES TTT 30 70 90 MINUTES FJ 1 2 s ms AON 1 70 6 HOURS " . HUA yng ays, IN YICINITY m 7 SSeO7, e Figure 17. Immersion Hypothermia, North Pacific. Twenty years of record (Navy Hydrographic Office 1961). Water Temp. (F) Exhaustion or Unconsciousness Expected Time of Survival 32.5 15 min. 15-45 min. 32.5-40.0 15-30 min. 30-90 min. 40-50 30-60 min. 1-3 hr. 50-60 1-2 hr. 1-6 hr. 60-70 2-7 hr. 2-40 hr. 70-80 3-12 hr. 3-Indef. 80 Indef. Indef. The above table relates water temperature to approximate survival time of humans immersed in the sea. Table 8. Immersion Hypothermia. Twenty years of record (Navy Hydrographic Office 1961). vs Station Longest Day Shortest Day Cold Bay 17h 26m 7h 07m Kodiak 18h 07m 6h 31m Homer 18h 44m Sh 59m The above length of day was computed as the time between sunrise and sunset. Table 9. Hours of Daylight, Western Gulf of Alaska (from Naval Observatory, 1959). ss 56 Literature Cited Air Weather Service, U.S.A.F. "Uniform Summary of Surface Weather Observations," Parts A thru E, for Kodiak (1963) and Cold Bay (1970). Branton, C. Ivan, Robert H. Shaw, Lee D. Allen. 1972. Solar and Net Radiation at Palmer, Alaska 1960-71. Institute of Agricultural Sciences, University of Alaska, Palmer. Environmental Data Service (NOAA). Publication dates unknown. Climato- graphy of the United States, Nos. 11-43, 86-43, 60-49. Local Climatological Data, Annual Summary with Comparative Data. Klein, W.H. 1957. Principal Tracks and Mean Frequencies of Cyclones and Anticyclones in the Northern Hemisphere. Weather Bureau Re- search Paper No. 40. McRoy, C. Peter. 1970. Solar Radiation Graph for Cold Bay. Institute of Marine Science, University of Alaska, Fairbanks. National Weather Service. 1973. Total Precipitation and Snowfall. (Unpublished maps). Prepared in cooperation with U.S. Geological Survey. Naval Observatory. 1959. Tables of Sunrise and Sunset, Kodiak and Cold Bay. Navy Hydrographic Office. 1961. Climatological and Oceanographic Atlas for Mariners, Volume II. North Pacific Ocean. Thom, H.C.S. 1968. "New Distributions of Extreme Winds in the United States." Journal of the Structural Division, Proceedings of the American Society of Civil Engineers. U.S. Weather Bureau. 1952. Normal Weather Charts for the Northern Hemisphere. Technical Paper No. 21. 57 IV. OCEANOGRAPHY INTRODUCTION The Gulf of Alaska, as well as the entire North Pacific, have been treated as examples of estuarine circulation (Tully and Barber 1960). This may seem farfetched, but by the broadest definition of estuary--a partially enclosed body of water with significant dilution by fresh waters from the land--the surface waters of the North Pacific qualify as a model of estuarine circulation. Many sizable rivers, either directly or indirectly, drain into the area. At the same time, the North Pacific is of normal oceanic depth and in free communication with the remainder of the Pacific and, to a lesser degree, with the Bering Sea and Arctic Ocean. The result is a broad region throughout which the surface waters show definite terrestrial influence, but which, below a well-developed regional pycnocline, show more normal oceanic characteristics (Fleming 1958). The characteristics of inshore, continental shelf waters around the North Pacific, particularly in the Gulf of Alaska, demonstrate a very marked seasonal variation. During the runoff season, they may be strongly influenced by fresh water inflow, while in winter, oceanic waters may dominate throughout (Royer, In Press). As well, the North Pacific is subject to violent storms which may, particularly in shelf areas, impose notable transitory changes in the waters. This discussion will concentrate upon the extreme northwestern part of the Gulf of Alaska, essentially the area from Kodiak Island to the end of the Alaska Peninsula at Unimak Pass. Within this restricted area there is considerable local influence from runoff, much of it highly turbid waters from the glaciated terrain of the Kenai and Alaska Ranges. The area is characterized by a relatively broad, smooth continental shelf of variable width, as much as 200 km. east of Kodiak Island, but narrowing to about 80 km. near Unimak Pass. There is one major group of islands--the Kodiak Archipelago--and numerous smaller islands on the shelf. The continental slope is extremely narrow and precipitous in the region, with slopes as great as five to six percent leading to abyssal depths in the Aleutian Trench which parallels the continental margin. The shelf here is one of the most productive areas of the North Pacific; it supports major fisheries for king, Dungeness, and tanner crab, shrimp, and a variety of bottom fish. Oceanic circulation prevails offshore, while inshore, seasonal terrestrial influences and upwelling produce the fertilization of the waters necessary to support the high local productivity. Because of the economic importance of the shelf fisheries and the great North Pacific salmon resource, there have been many episodes of oceanographic research in the region. Inaccessibility, severe weather 58 conditions, and political and economic factors have routinely limited the scope of these studies, but by combining material from United States, Soviet, Japanese, and Canadian sources spanning 40 years, a general picture of the oceanography of the Gulf of Alaska can be deduced. This discussion will first review the relatively constant offshore characterisitics and circulation and then proceed to the more complex and more poorly understood situation of the continental shelf waters. OFFSHORE CIRCULATION The general geostrophic circulation around the Gulf of Alaska flows counterclockwise (Figure 18). The Subarctic Current, part of the West Wind (North Pacific) Drift, carries water eastward across the Pacific, and then splits to form the Alaska Current and California Current. The broad, slow Alaska Current flows north and then west, passing southwest of Kodiak Island. In the vicinity of Kodiak Island, the current becomes narrower and more intense, forming the Alaska Stream, which flows along the Alaska Peninsula and Aleutian Islands to terminate somewhere in the vicinity of 175°W. Some portion of the stream flows into the Bering Sea, and the remainder doubles back into the Subarctic Current to make the Alaskan Gyral a somewhat closed system (Uda 1963). Both the Alaskan Stream and Alaska Current are most intense near the edge of the continental slope. Flows as high as 25 cm./sec. have been estimated in the intense region of the Alaska Current off Vancouver Island with estimates of 5-20 cm./sec. elsewhere. Estimated flow of the Alaska Stream in the study area is 25-50 cm./sec., although some ship drift determinations as great as 75 cm./sec. have been made west of Kodiak. Transport éstimates for the Alaska Gyral are 1 to 10x10® m.3/sec. (Favorite 1970). Most estimates of currents in the Gulf of Alaska have been from geostrophic calculations based on hydrographic data (Thompson et al. 1936, McEwen et al. 1930, Favorite 1970). Dynamic current calculations made on data collected since 1928 are fairly consistent; examples of surface and 100 m. depth current in the Northern Gulf of Alaska are shown in Figure 19. The greatest currents, on the order of 50 cm./sec., lie near the shelf break. Also, on the Cape Clear line an eastward countercurrent of over 40 cm./sec. is seen on the shelf. Because the Gulf of Alaska geostrophic currents are somewhat sluggish, the actual surface currents are influenced greatly by strong winds associated with the frequent storms in the Gulf and by the long- term wind conditions (Boisvert 1969, Searby 1969). In winter, the usual position of the Aleutian low over the Gulf of Alaska generates winds that cause the Alaskan Gyral to increase its transport and dimensions (Figure 20). The greater winter flow and Coriolis intensification cause an increase in mean sea level along the Gulf of Alaska coast nearly 12 180° 170° __!60° 150° 140° 130° 120° 180° 170° 160° 150° 140° 1308 720° Figure 18. General circulation, North Pacific Ocean--1 mi./day ¥ 2 cm./sec; 50 cm./sec. £1 knot (adapted from Dodimead, Favorite, Hirano 1962). 6s 60% 58°, CAPE ST. EL! ) L/ET™ OCEAN CAPE CHINIAK pe ° 50Cm/Sec. ——— ° 1.0 Kts. A. SURFACE 146° 144° 140° 138° 144° 140° 136° 56° CAPE CLEAR CAPE nm DT CHINIAK ° 50 Gm./Sec. ° 1.0 Kts. \ B.100 METER LEVEL the average calculated current at the surface (A) and 100 M. level (B) shown by vectors. Cape Chiniak, Cape Cleare and Ocean Cape sections, Northern Gulf of Alaska, January (from Thompson et al. 1936). 58° 180° 165° 150° 135° 120° 105° 70° 60% 60° 50 50° 404 40° 165° 150° 135° 180° 165° 150° 135° zoe 105° - - 70° 60° 50° | 50° 409| > 40° 165° 150° 135° Figure 20. Permanent currents in the Gulf of Alaska. A - winter; B - summer (from Plathotnik 1964). 62 . cm. above the yearly average (Pattulo 1960). Analysis of Soviet hydrographic data from the Gulf of Alaska has revealed the erratic development of eddies and meanders at the inshore margin of the Alaska Current (Plakhotnik 1964). These eddies are probably at least due in part to local storms (Figure 21). There have been no physical measurements of offshore currents in the Gulf of Alaska, so there is no direct confirmation that the geostrophic calculations are correct. Drift bottle experiments have been performed sporadically since 1930, and have been useful to define the boundaries of the Alaska Gyral, but they cannot clarify exact paths or speeds during transit (Favorite 1964, Fisk 1970). The driving forces responsible for the offshore circulation in the Gulf of Alaska clearly include both geostrophic and wind-stress components (Roden 1969, Favorite 1970, Royer 1972). From a study of vertical profiles of salinity and temperature, Roden (1969) determined that the winter intensification of flow is very closely tied to the wind field produced by the persistent barometric low centered in the Gulf. This added wind stress alone may produce current velocities in excess of 20 cm./sec. near the edge of the continental shelf. Also, the circulation induces a divergence in the Ekman transport of surface waters, causing upwelling in the central Gulf. Wind stress transport calculations based on monthly mean sea level barometric pressure patterns yield transport calculations that are in fair agreement with geostrophic calculations (Favorite 1970). A plot of such computed transport suggests that mean flow of about 11x10 m.3/sec. to the east occurs in the Alaska Stream near the edge of the continental shelf (Figure 22). Transport computations for the North Pacific are available for the years 1946 through 1968 (Fofonoff 1960, 1961, 1962; Fofonoff and Ross 1962; Fofonoff and Dobson 1963; Wickett 1966, 1967). Royer (1972) summarizes the climatologic influence upon circulation in the Gulf and emphasizes the consequences of the normal meteorologic pattern in the area. Throughout the year, but primarily in winter, masses of relatively cold, dry arctic air are drawn over the Gulf where they rapidly absorb both heat and moisture from the warmer sea waters. This heating results in vertical convective movement of air massses and a horizontal divergence of the sea surface, exaggerating the influence of the Gulf low and accelerating the existing geostrophic current. INSHORE CIRCULATION Very little is known of the actual circulation over the Gulf of Alaska continental shelf. The Alaska Stream has considerable influence at the outer margin of the shelf, as discussed above, and presumably induces a general net drift toward the west of all the shelf waters. In summer, when the East Pacific High extends into the Gulf of Alaska, deflection of coastal waters would tend to counter this drift. In 160°w 150° 145° 160°w 159° 145° T r T 7 T 160°w 150° 145° a. April - May 1961 b. October, 1961 Figure 21. Surface current charts (from Plakhotnik 1964). 55° €9 160° 150° I40° 130° T T T T T TT T T é ALASKA ' CANADA 60° 55° 55° uF one psonr” = Ay 22 50° 5 5 5 50° 8 5 | 45°} t 8 8 6 45° ha 180° 170° 160° 150° 140° ~ : 130° Figure 22. Flow (wind-stress transport [x 10° m/sec] ) in the eastern North Pacific Ocean determined from records of sea level pres- sure, February 1970. Insert shows flow computed from occano- graphic data obtained at indicated stations (from Favorite 1970). . 9 waters shallower than 200 m., particularly near inshore, local influences make generalization unwise. Along the Gulf of Alaska continental shelf, the most important controls upon circulation (aside from the Alaska Stream) appear to be the tides, seasonally variable fluvial runoff, and topographically controlled local wind effects. Offshore circulation in the Gulf region, described above, was largely inferred from geostrophic and wind induced transport computations. These cannot be used to infer circulation over the shelf because of the shallow water, irregular boundaries, and the often dominant influence of tidal currents. One series of current determinations has already been presented (Figure 19), but inshore this technique only yields an approximation. Drift bottle or drift card observations can be useful to plot inshore circulation, but their utility depends upon the presence of an active beachcombing fraternity; thus, in Alaska waters they can give only general suggestions of current flow. Among the most useful data here are the direct observations of coastal navigators which are codified in the Coast Pilot (U. S. Coast and Geodetic Survey 1964) and the generalized surface current plots (U. S. Navy Hydrographic Office 1961). Tide tables also may be very useful in some areas. Recently, valuable information on Alaskan coastal currents has been obtained from Earth Resources Technology Satellite (ERTS) imagery which clearly shows the trajectory of turbid river waters on the sea surface (Wright et al. 1973). A very generalized plot of the inshore water surface circulation pattern for the Gulf, based upon all available information, is given in Figure 23. Tides are an important factor in circulation on the Gulf of Alaska continental shelf. They are of the typical west coast mixed form with a marked diurnal inequality superimposed on the semidiurnal tide. Amplitudes along the Gulf coast are considerable, usually in the range of 2-4 m. (Table 10). Cook Inlet, the major estuary immediately north of the study area, has one of the greatest tidal amplitudes known, in excess of 10 m. at spring tides. Tidal amplitudes and currents have been measured near Middleton Island, which lies at the edge of the continental shelf a few tens of kilometers east of the study area. There the tidal variation over the open shelf is about 3 m. If this value for the tidal range is accepted for the entire shelf, the resulting maximum tidal current velocities (Umax) at various depths in the water column (d) can be calculated using the shallow water wave approximation: Wl Unax = H g where H = tidal amplitude 2 d g 9.8 cm. sec.-2 Calculated current velocities are given in Table 11; and they are in general agreement with tidal currents reported for the area in the Coast Pilot. The flood current in the area usually trends north, while the ebb is to the south. The pattern of currents is extremely variable, however, particularly close inshore where they are most noticeable. le, Seitz, Institute of Marine Science, University of Alaska, Personal communication. ° 164' 162° 160° 158° 156° 154° 152° 150° n } r INLET 2 ssf eure 23. Surface currents, Western ** — Culf of Alaska (compiled J) } Ose C y"° . from various sources by i— Fr. F. Wright, Marine Geo- > Cones oA So? logist, Marine Advisory o Service, Univ. of Alaska, 5 & Anchorage. Wy 9 <= 58° 56° 4 Ww OFFSHORE WATERS eo” Ge coastal WATERS 57° ol 57° oY o* \ ~ @ ¢ ——= ® g 0 100 KM ° ot" ° 56 y p ° V 56 » Ke ‘ ve Q , 00 ony ea : ; ee snd, NS 7 AS SHUMAGIN IS. O Se - Sy / Se Se e So D re a ae i WN _—— _— — rai a 164° 162° 160° 158° 156° 154° 152° 150° 99 Mean Range* Diurnal Range* Place Ft. M. Ft. M. Barren Islands 11.4 3.5 13.7 4.2 Ouzinkie, Spruce Island 7.0 2.1 9.1 2.8 Kodiak Harbor 6.6 2.0 8.5 2.6 Port Hobron 6.4 1.9 8.3 2.5 Uyak 11.3 3.4 13.8 4.2 Uganik Passage 11.9 3.6 14.6 4.4 Shuyak Island 11.5 3.5 13.9 4.2 Kukak 11.1 3.4 13.3 4.0 Shumagin Islands 5.6 1.7 7.8 2.4 Beaver Bay 5.2 1.6 7.3 2.2 Pavlof Bay 5.2 1.6 7.2 2.2 Cold Bay 5.2 1.6 7.1 2.2 Sanak Harbor 4.4 1.3 6.6 2.0 Scotch Cap, Unimak Pass 3.3 1.0 5.4 1.6 *Note: Mean range is the difference in height between mean high and mean low water; diurnal range is the difference between mean higher high water and mean lower low water. Table 10. Representative tidal ranges, Western Gulf of Alaska (from National Ocean Survey 1973) 68 Depth Current Velocity (m.) (knots) (cm. /sec.) 10 2.9 149.3 20 2.05 105.6 50 1.3 67.0 100 0.9 46.3 200 0.65 33.5 Table 11. Calculated maximum tidal currents at various depths on an open shelf for a tidal amplitude of 3 m. 69 Heavy tide rips occur at many points along the Gulf coast. Measured tidal currents at representative sites in the area are given in Table 12. At these stations flood velocities commonly exceed the ebb tides. The other two factors in coastal circulation are much more erratic. During the runoff season in southern Alaska, the inshore circulation is significantly modified by the large volume of fluvial waters. In an embayment, this runoff factor typically may retard the flood and accelerate the ebb tide. Wind stress, the final factor, is also important as a hazard to navigation and as a potent mechanism of mixing in the surface waters. Its direct influence upon current velocities is apparent only in the open ocean, but inshore along the coast severe storms known as williwaws may develop suddenly and cause much local disturbance. Prevailing winds over the entire shelf in winter tend to assist the ubiquitous westward drift of the Alaska Stream, but they may retard it somewhat in the summer. The current regime in Shelikof Strait between the mainland and the Kodiak Group is particularly interesting but poorly known. A significant southwest current hugs the mainland shore much of the time. This current is the result of tidal outflow from Cook Inlet and is clearly defined in satellite imagery of the area (Wright et al. 1973). Particularly in winter, this southwest flow is intensified by the pile- up of water from the Alaskan Stream in the Barren Islands sector at the mouth of Cook Inlet (Roden 1969). The Coast Pilot (U. S. Coast and Geodetic Survey 1964) states that the flood tide sets into Shelikof Strait from both ends, contributing to the complexity of the situation. Currents have not been measured in the Strait itself, but vessels report sets commonly in excess of 1 knot (51.5 cm./sec.) in either direction through much of the Strait. Logan (1970) and the Coast Pilot (U. S. Coast and Geodetic Survey 1964) are the only known sources of information on currents immediately south of Kodiak Island. They report that Sitkinak Strait, separating the Kodiak from Sitkinak and Tugidak Islands, is the site of major tide rips, and under certain conditions whirlpools and very severe seas may develop. When a strong ebb meets an easterly storm from the Gulf or when a strong flood into Shelikof Strait meets a westerly gale, conditions are particularly severe. Average ebb currents are reported to be 2.3 knots (118 cm./sec.) to the east and the flood 1.9 knots (98 cm./sec.) to the west (U. S. Coast and Geodetic Survey 1970). Similar conditions occur on the shoal area between Tugidak and Chirikof Islands known as 17 Fathom Bank. Here Logan (1970) mentions currents as great as 3 knots (154 cm./sec.) and violent seas. Two Liberty Ships cracked their plates and a tug foundered in this area in the winter of 1942. To the west, on the open shelf between Kodiak Island and Unimak Pass, the regime is strongly influenced by the Alaska Stream. The set is always to the west and has been reliably reported to average about 1.5 knots (77 cm./sec.) west of Chirikof Island (U. S. Coast and Geodetic Survey 1964). Greater currents are believed to occur around the Semidi and Shumagin Islands. This current is particularly sensitive Place Flood Ebb Difference kts. cm./sec. kts. cm./sec. (Flood-Ebb, cm./sec.) Chugach Passage 3.1 159.6 1.8 92.7 66.9 Shuyak Strait 3.8 195.7 3.8 195.7 0 Whale Passage, N.W. Entrance 4.6 236.9 2.6 133.9 103.0 Whale Passage, Off Bird Point 4.4 226.6 5.2 267.8 -41.2 Kodiak Harbor 0.9 46.4 0.5 25.8 20.6 Sitkinak Strait 1.9 97.8 2.3 118.4 -20.6 Unga Strait, Shumagin Island 1.2 61.8 0.2 10.3 51.5 Unimak Island, N. of Otter Pt. 0.9 46.4 0.8 41.2 5.2 Unimak Pass, Scotch Cap 3.4 175.1 3.0 154.5 20.6 Table 12. Representative surface tidal currents along the W. Gulf of Alaska (from U. S. Coast and Geodetic Survey 1970) 02 71 to the common northeast storms; often it intensifies noticeably toward the southwest as much as a day before the barometer falls. WATER TYPES GF THE WESTERN GULF OF ALASKA There are three major domains of distinctive surface waters in the Gulf of Alaska. These are the relatively static region of the central Alaska Gyral, the westflowing Alaska Stream which parallels the continental margin, and the coastal waters (McEwen et al. 1930). There are significant seasonal changes in the circulation of all these areas. The Gyral and its associated Alaska Stream are intensified in winter, when runoff is moderate. During this season, offshore waters may dominate all of the open segments of the shelf. In summer, a weakening of the Alaska Stream and large volume runoff from the hinterland may expand the coastal domain to cover much of the shelf. In the offshore waters of the Gyral and the Alaska Stream, there is usually a clearly developed pycnocline which appears to be between 100 and 150 m. in depth (Dodimead 1961, Uda 1963, Tully 1964). The thermocline, which is often at a more shallow depth than the major pycnocline, responds dramatically to seasonal influences, but almost invariably shows a temperature maximum, beneath the surface (Figure 24). In winter, a thick, isothermal and isohaline surface layer with a temperature below 3.5 degrees C is produced by wind mixing and heat losss to the atmosphere. This layer is commonly about 100 m. thick. During summer, this same layer is rapidly warmed by insolation, and one or more secondary thermoclines may develop, reflecting episodes of heating punctuated by storm mixing (Uda 1963). Surface waters may exceed 12 degrees C, but normally drop to the winter surface value of 3.5 degrees C or less at depth. The halocline is more stable, but also shows strong seasonal influence (Dodimead 1961). In the winter, surface waters are about 32.8°/oo with the halocline falling at a depth between 100 and 200 m. and the deeper water increasing gradually in salinity to 33.7°/oo0 (Uda 1963). In summer, the influence of runoff and precipitation significantly lowers the salinity at the surface. Again, reflecting the recent meteorologic history, there may be a number of minor haloclines. Typical summer offshore water characteristics can be seen in the Temperature-Salinity diagram of conditions south of Kodiak Island and to the west of the Shumagin Islands (Figure 25). Location of stations and profiles are shown in Figure 26. Profiles of temperature, salinity, and dissolved oxygen concentration in the open shelf waters are presented in Figure 27. The thermal regime is somewhat confused, but the salinity profile clearly shows the presence of normal offshore water in the deep which separates Albatross Bank from Kodiak Island. Such ponded masses of normal marine waters are believed to persist throughout the summer in topographic depressions on the Gulf of Alaska shelf. Royer (In Press) believes that the surface water mass behavior on the shelf is highly responsive to atmospheric pressure fields over the Gulf. He emphasizes annual flushing as a result of downwelling in winter and upwelling in ( meters ) DEPTH 100 300 SALINITY (%o) TEMPERATURE (°C) 32.5 33.0 33.5 34.0 3 5 6 7 8 9 10 I TT | T T T T T T T T T T T_T rs (Or s ‘ . R iO | \, UPPER ZONE a | SUN NE : (SEASONAL) E _-- THERM a = bess Soba See ee et q TEMPERATURE L MAXIMUM : HALOCLINE LOWER ZONE | (NON-SEASONAL) 4 1 | ! | | ! | | ! | Figure 24. Thermohaline structure offshore Gulf of Alaska (adapted from Dodimead 1961). tL 12 10 SHUMAGIN SHELF Redwing— 8 e ed \ Yio 50 mee 20% \, 100 / 6 GULF OF 9 i ALASKA oo B-10 F 30 75 75 o~, 150 , 4 ‘one 150 Ns SHELIKOF STRAIT 2 6-3 & 0 “ 6] -2 1 {oo 30 3I 32 33 34 35 S %o Figure 25. Typical summer water characteristics on the Western Gulf of Alaska continen- tal shelf. Depths in meters. See Figure 26 for station locations ffrom Wright 1970, and unpublis! ta Center). ec data from National Oceanographic | gra} £2 59° 58° 57° 56° 55° 54° 164° 162° 160° 158° 156° 154° 152° 150° Figure 26. Location of oceanograph- ic stations and profiles, Western Gulf of Alaska. 59° 58° © OCEANOGRAPHIC STATIONS MMMM OCEANOGRAPHIC PROFILES 57° 55° 54° 164° 162° 160° 158° 156° 154° 152° 150° (M) DEPTH 1SOr 200r 2507 300- 400F ALBATROSS BANK TEMPERATURE (°C) KODIAK ISLAND SALINITY ALBATROSS BANK (S%o) KODIAK ISLAND ALBA oe DISSOLVED OXYGEN (mi/1) Figure 27. Wright 1970). SCALE ° 15 30 a NAUTICAL MILES Profiles of oceanographic conditions seaward of Kodiak Island, Line B, June 1967 (from SZ 76 summer. Pycnocline depth offshore may coincide with outer continental shelf depths in the Gulf area, but clearly defined structure in the water column over the outer shelf is rarely seen. Inshore the thermocline structure is more complex and seasonally variable due to the complex terrestrial influence of runoff. Runoff in this region may carry large quantities of silt and clay in suspension (glacial flour) derived from the alpine glaciers common in the coastal ranges. Such turbid waters have sometimes been observed on the sea surface in such areas as Shelikof Strait, probably as a very thin layer of brackish, sediment-laden water which may be no more than centimeters thick (Wright 197la). Within certain Alaskan fjords, discrete layers of turbid water may spread on density interfaces beneath the surface or settle to the bottom and there move as turbidity flows (Wright 1971b). It is not known if such phenomena occur in the waters of the open shelf, but it is possible; Cook Inlet and Copper River waters have been observed offshore at the surface in satellite imagery (Wright et al. 1973). The cold meltwater runoff in spring can lead to some curious effects. Upwelling of oceanic waters may take place in which the upwelled waters are warmer than the coastal waters they replace. This is in contrast to the situation on temperate and tropical shelves. Inshore surface water temperatures in summer, because of insolation in bays, may reach values greater than 15 degrees C, but it is more normal to see values of 9-12 degrees C. Typical spring and fall surface water temperatures and a fall bottom water temperature distribution are given in Figure 28 (Shurunov 1964). The plot of surface conditions in the fall definitely suggests the occurrence of eddies developed from the Alaska Stream in the region just east of Kodiak Island. The distribution of bottom water shows an apparent intrusion of oceanic (colder) waters just west of Kodiak, along the trend of the topographic depression leading into Shelikof Strait. Apparently, normal sea waters may intrude far onto the shelf at times during summer and fall. It has been suggested that the distribution of benthic fish on the shelf may be closely related to these intrusions and to the ponded oceanic waters that may be left behind when the halocline recedes (Plakhotnik 1964). The temperature-salinity relation in Shelikof Strait, an area strongly influenced by drainage from Cook Inlet, is shown in Figure 25. Profiles of the conservative water characterisitcs in the Strait are given in Figure 29. Water of normal offshore salinity appears toward the mainland side at the south end of the strait. MIXING PROCESSES AND NUTRIENTS A variety of mechanisms maintain nutrient values in the Gulf of Alaska. In the central Gulf, as already described, winter upwelling pic. Royer, Oceanographer, Institute of Marine Science, University of Alaska, Fairbanks, personal communication. SURFACE WATER TEMPERATURE (MARCH) ° oS Fant WATER TEMPERATURE (OCTOBER) 408 ce BOTTOM WATER TEMPERATURE (OCTOBER) c° Figure 28. Water temperature on the Gulf of Alaska shelf, 1961 (from Shurunov 1964), 77 (M) DEPTH 0 15 30 NAUTICAL MILES NORTH END -LINE H K ALASKA rane MAINLAND ° 05 10 20 30 50 75 100 150 200 TEMPERATURE SALINITY DISSOLVED OXYGEN (°C) (%o) (ml/1) SOUTH END—LINE F KODIAK ALASKA ISLAND MAINLAND 150 200 Figure 29. Profiles of oceanographic conditions in Shelikof Strait, June 1967 (from Wright 197C). 82 79 appears to be a common phenomenon and these waters are distributed and mixed by both wind action and the geostrophic currents (Roden 1969). Classic coastal upwelling is believed to occur to some degree along this continental margin, usually between April and August, but is apparently quite minor (Royer, In Press). Downwelling, particularly in the winter, May occur on the shelf (Bakun 1973). The principal mechanisms of re- plenishment of the nonconservative elements in the surface waters of the shelf appear to be storm-wind induced mixing, which may occur at any season; turbulent mixing where the Alaska Stream or tidal currents are perturbed by irregular shelf topography; and the introduction of nutrients from terrestrial runoff. There has been insufficient detailed study of the nutrient budget of the area to assess the relative importance of these factors. There is clearly very significant seasonal variation in these input terms, just as high latitude insolation and water temperature effects vary consumption of the essential nutrients. The chemical oceanography of the Gulf of Alaska has recently been reviewed by Longerich and Hood (1972). They summarize, in particular, detailed studies of nutrient and other chemical data in the fjords and embayments of the coast plus a variety of generalized studies covering the entire North Pacific. Only a single cruise investigating chemical parameters has been conducted on the continental shelf in the Western Gulf of Alaska. This was conducted in June of 1967 and was restricted to the area immediately around Kodiak Island (Wright 1970). Nutrient concentrations for stations in Shelikof Strait and on the open shelf southeast of Kodiak Island are given in Table 13, and the conservative water characteristics at these stations are given in Figures 27 and 29. The values are rather erratic, reflecting the intense activity of the season. June is the month of greatest insolation and maximum terrestrial runoff. Also, a severe local storm occurred during sampling in Shelikof Strait, interrupting the operation and further serving to mix the waters. In general, all the nutrient profiles show a surface mixed layer from 20 to 50 m. thick in which nutrients, particularly silica, are low. This reflects the seasonal high activity among the phytoplankton. In the deeper waters, nutrient values are relatively high. Waves A large proportion of the waves over the open continental shelf of the Gulf of Alaska tend to fall into the category of sea. Many significant waves are generated by large storms in the North Pacific (Extratropical Cyclones) and they are still in the process of development when they enter the study area. As sea, these waves tend to be rather irregular in period and height and to have a trochoidal form, rather than the sinusoidal form typical of swell. Trochoidal waves have relatively broad, flat troughs and sharp, peaked crests, and affect ships out of proportion to their absolute size. These waves are generated by violent storms which tend to travel westward or northeastward parallel to the continental margin. Winds associated with these storms may exceed 50 knots (92.5 k.p.h.) and their duration is often 30 to 40 hours (U.S. Coast and Geodetic Survey 1964). The effective fetch to the southwest TABLE 13 Nutrient Concentrations in Kodiak Shelf Waters, June 1967 (from Logerich and Hood 1972). See Figure 26 for location of stations. 80 Water Nutrients yg At/1 Lat. (N) Long. (W) Depth PO NH NO NO Sid, 4 3 2 3 2 (m) F-i 57°35.0' 154°32.3' 0 0.58 1.60 0.05 0.00 13.9 10 0.61 1.70 0.07 0.10 12.0 20 0.58 1.20 0.07 0.20 12.0 30 0.54 0.90 0.07 0.20 12.9 50 0.74 1.70 0.11 0.60 14.0 F-5 57°49.0' 155°05.0' 0 0.30 0.80 0.05 0.00 2.0 10 0.30 1.90 0.05 0.00 1.0 20 0.35 1.10 0.05 0.00 1.9 30 0.33 0.70 0.04 0.00 1.0 50 0.52 1.80 0.06 0.40 330: 75 1.04 2.20 1.14 1.90 11.0 100 1.25 4.20 0.20 3.60 15.0 150 1.42 3.40 0.39 3.30 22.0 200 2.14 0.90 0.906 8.40 46.0 B-1 57°08.0' 152°50.5' 0 0.47 1.00 0.06 0.10 5.0 10 0.55 1.20 0.08 0.20 --- 20 0.84 2.30 0.12 1.10 11.0 30 0.96 4.50 0.13 1.20 13.0 50 1.10 4.60 0.14 2.10 16.0 75 1.20 5.50 0.15 2.60 18.0 B-i0 56°36.5' 151°52.0' 0 0.55 1.20 0.03 0.00 2.0 10 0.52 0.60 0.07 0.40 1.0 20 0.78 1.00 9.13 1.70 6.0 30 1.46 2.00 0.19 4.10 24.0 50 1.73 0.20 0.17 7.60 31.0 75 1.92 0.10 0.07 7.00 39.0 100 2.10 0.00 0.03 9.70 47.0 150 2.48 0.00 0.02 10.7 54.0 200 2.64 0.00 9.03 10.6 65.0 300 3.15 0.70 0.01 13.5 88.0 400 3.26 0.40 0.93 17.2 --- 81 may exceed 1,000 nautical miles (1,850 km.), so theoretically, waves could be generated with a period of about 18 seconds and a significant height of 50 feet (15 m.); (Pierson et al. 1955). There have been unsubstantiated reports of waves of this size in open water in the Gulf, but reliable witnesses with much local experience report that they have never observed waves greater than 30 feet (9 m.) Searby 1969). Observations of open water waves have been collated in the Climatologic and Oceanographic Atlas for Mariners (Navy Hydrographic Office 1961). These data suggest that during the stormiest season (fall) no more than 10 percent of the waves would have heights greater than 12 feet (3 m.) (Figure 30). An extensive computer model study of the oceanographic climate in the region immediately to the east of the study area has recently been completed by a consortium of petroleum firms.) a summary of this study indicates that in fall there is less than 25 percent probability of waves offshore exceeding 14 feet (4 m.). Such broad-scale studies cannot, of course, consider local problem areas where violent seas over shoals may be produced by winds counter to the currents. Two places within the study area are particularly noted among mariners for difficult wave conditions, the "Heel" (southwest entrance) of Shelikof Strait (Logan 1970) and "Shumagin Gully," west of the Shumagin Islands.2 TSUNAMIS Tsunamis or seismic sea waves are not uncommon in the study area. Tsunamis are ocean waves of extremely long period, typically 10-70 minutes. Their length from crest to crest may be hundreds of kilometers and their height from trough to crest only a few meters. In the open ocean, they cannot be felt aboard ship or seen from the air, but they possess impressive energy. Tsunamis are believed to originate as vertically displaced columns of ocean water, but the displacing mechanism may vary. Volcanic alterations of the sea floor or submarine avalanches have been proposed as origins of tsunamis, but most tsunamis appear to be associated with seismic activity. Long-period ground waves or large-scale tectonic displacement of the sea floor associated with earthquakes are generally thought to be the causes. Tsunami magnitude appears to be a function of several factors; earthquake magnitude and depth, water depth in region of tsunami generation, extent and velocity of crustal deformation, and the efficiency of energy transfer from the earth's crust to sea water (National Academy of Sciences 1972). A tsunami "feels the bottom" even in the deepest ocean, and its speed is controlled by the depth of water. In the deep ocean, speeds as loule of Alaska Operators Committee. 1973. Gulf of Alaska Oceanographic Environment. Part 1 of 5. Unpublished report. 2s, Yaeger, Mariner, Kodiak, Alaska, personal communication. AUTUMN SEAS ©5FT) WINTER SEAS @5FT) SPRING s SEAS @5FT) Figure 30. Percentage frequency of seas = 5 ft. (from Searby 160° 1 | 150° 150° 7 160" 150° _140° 1 1 od AUTUMN WINTER SEAS @8FT SEAS @8FrT & ) B wae &8FT) 150° 140? 160° 150° ? 7 SPRING SEAS @8FrtT) SUMMER SEAS @8FT) Figure 30, Continued. Percentage frequency of seas =8 ft. (from Searby 1969). i : ~ | 160° 150° 140° 160° 150° 180° | e@ \, AUTUMN Dy SEAS @i2FT) od WINTER SEAS @il2rr) 20 160 150° 140° 160° 150° 140° T V7 + | SPRING b> % SEAS Gort) 0, Continued. Percentage frequency of seas = 12 ft. (from Searby 1°69). e@ 85 high as 900 km. per hour may occur. Travel time charts can be prepared to predict approximately when a tsunami generated in a specific area will arrive in another specific area. As a tsunami enters the shoaling water of a coastline, its velocity diminshes, but wave height increases. It is still not possible to accurately predict the wave height of a tsunami as it hits shore; its height may be almost negligible, or it may form crests of considerable height and strike the coast with devastating force. The height of the wave depends on various factors, such as slope of the ocean floor, direction of wave propagation, and speed of the waves. Usually such long period waves are unnoticed over the outer continental shelf. Tsunamis are most common in the Pacific Ocean; 66 out of 84 (80 percent) of those reported between 1928 and 1963 occurred in this region (U. S. Coast and Geodetic Survey 1965). Because it is a zone of high earthquake activity, the Gulf of Alaska-Aleutian Islands area is a significant generator of tsunamis. Perhaps the most spectacular example of a tsunami generated in the region was during the 1964 Alaska earthquake. A detailed discussion of the cause, effect, and response of this destructive wave is found in a recently published volume (National Academy of Sciences 1972). Another type of tsunami that can cause damage in restricted harbors and bays also is commonly associated with earthquakes. These waves are generated by earthquake triggered landslides that displace water in the bay and cause waves that can reach elevations more than 60 m. above sea level. This type of wave occurred in Port Valdez during the 1964 earthquake and caused extensive loss of life and property. 86 Literature Cited Acara, A. 1962. "On Warm and Cold Years in the North Pacific Ocean." Fish. Res. Bd. Canada. M. S. Rept. Ocean and Limnol. No. 134. Bakun, 1973. Coastal Upwelling Indices, West Coast of North America, 1946-1971. U. S. Department of Commerce, National Oceanic and Atmospheric Administration. Technical Report National Marine Fisheries Service SSRF-671. 103 p. Boisvert, W. E. 1969. Major Currents off the West Coast of North and South America. U. S. Naval Oceanographic Office. Technical Report 221. Dodimead, A. J. 1961. "Some Features of the Upper Zone of the Subarctic Pacific Ocean." Int. North Pacific Fisheries Commission Bulletin 3: 11-74. Dodimead, A. J., F. Favorite, and T. Hirano. 1963. "Review of Oceanography in the Subarctic Pacific Region." Int. North Pacific Fisheries Commission Bulletin 13, 195 p. Favorite, F. 1964. "Drift Bottle Experiments in the Northern Pacific Ocean 1962-1964." J. Oceanographic Society of Japan 20 (4): 6-13. Favorite, F. 1970. "Fishery Oceanography-VII. "Estimation of Flow in the Gulf of Alaska." Commercial Fisheries Review 32(7): 23-9. Fisk, D. M. 1970. "Results in 1964-68 of Drift Bottles Released From a Merchant Vessel, SS Java Mail enroute Seattle to Yokohama, Oct. 1964."" Pacific Science. Fleming, R. H. 1958. "Notes Concerning the Halocline in the Northeastern Pacific Ocean." J. Marine Research 17(2): 158-173. Fofonoff, N. P. 1960. "Transport Computations for the North Pacific Ocean 1955-1960."" J. Fish Res. Bd. Canada, M. S. Rept. Ocean. and Limnol. Nos. 77-80. 93 p. Fofonoff, N. P. 1960. "Transport Computations for the North Pacific Ocean 1959-1960."" J. Fish. Res. Bd. Canada, M. S. Rept. Ocean. and Limnol. Nos. 85, 93. 18 p. Fofonoff, N. P. 1962. "Machine Computations of Mass Transport in the North Pacific Ocean." J. Fish. Res. Bd. Canada 19(6): 1121-1141. Fofonoff, N. P. and C. K. Ross. 1962. "Transport Computations for the North Pacific Ocean, 1961." J. Fish. Res. Bd. Can., M. S. Rept. Ocean. and Limnol. No. 128. 94 p. 87 Fofonoff, N. P. and F. W. Dobson, 1963. "Transport Computations for the North Pacific Ocean 1950-1954; 1962." J. Fish. Res. Bd. Can., M. S. Rept. Ocean and Limnol. Nos. 149-53, 164 p. Logan, B. J. 1970. "Report on Alaska Ports." Unpublished Manuscript, 145 p. Longerich, L. and D. W. Hood. 1972. "Chemical Oceanography of the Gulf of Alaska." In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R 72-23. McEwen, G. F., T. G. Thompson, and R. Van Cleve. 1930. Hydrographic Sections and Calculated Currents in the Gulf of Alaska 1927 and 1928. Rept. Intl. Fish. Comm. 4. National Academy of Science. 1972. The Great Alaskan Earthquake: Oceanography and Coastal Engineering. Washington, D. C. 556 p. National Ocean Survey. 1973. Tide Tables, West Coast of North and South America. N. 0. A. A. U. S. Dept. of Commerce, Washington, D.C. 222 p. Patullo, J. G. 1960. "Seasonal Variations in the Pacific Ocean During the International Geophysical Year, 1957-1958."" J. Marine Res. 18-3: 168-184. Pierson, W. J., Jr., G. Neumann, and R. W. James. 1955. Practical Methods for Observing and Forecasting Ocean Waves by Means of Wave Spectra and Statistics. Dept. of the Navy, U. S. Naval Oceanographic Office. H. 0. Pub. No. 603. Plakhotnik, A. F. 1964. "Hydrologic Description of the Gulf of Alaska." In: Soviet Fisheries Investigations in the Northeast Pacific Ocean. Part II. All-Union Scientific Research Institute of Marine Fisheries and Oceanography (VNIRO). Trudy Vol. 49 P. A. Moiseev, ed. pp. 13-47. Transl. by Israel Program for Scientific Translations. Roden, G. I. 1969. "Winter Circulation in the Gulf of Alaska." J. Geophysical Res. 74(18): 4523-4534. Royer, T. C. 1972. "Physical Oceanography of the Northern Gulf of Alaska." In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R 72-23. Royer, T. C. In Press. "Seasonal Variation of Surface Waters in the Gulf of Alaska." Deep Sea Research. Searby, H. W. 1969. Coastal Weather and Marine Data Summary for the Gulf of Alaska, Cape Spencer Westward to Kodiak Island. U. S. Department of Commerce, Environmental Science Service Administration. E.S.S.A. Tech. Memo. E.D.S.T.M. 8, Silver Spring, Md. 30 p. 88 Shurunov, N. A. 1964. "Water Masses in the Western Part of the Gulf of Alaska." In: Soviet Fisheries Investigations in the Northeast Pacific Ocean. Part III. All-Union Scientific Research Institute of Marine Fisheries and Oceanography (VNIRO). Trudy Vol. 53. P. A. Moiseev, ed. pp. 144-149. Transl. by Israel Program for Scientific Translations. Thompson, T. G., G. F. McEwen, and R. Van Cleve. 1936. Hydrographic Sections and Calculated Currents in the Gulf of Alaska, 1929. Int'l. Pacific Halibut Commission. Tully, J. P. and F. G. Barber. 1960. "An Estuarine Analogy in the Subarctic Pacific Ocean." J. Fish. Res. Bd. Canada 17(1): 91-112. Tully, J. P. 1964. "Oceanographic Regions and Assessment of Temperature Structure in the Seasonal Zone of the North Pacific Ocean." J. Fish. Res. Bd. Canada 21(9): 941-970. Uda, M. 1963. "Oceanography of Subarctic Pacific Ocean." J. Fish. Res. Bd. Canada 20(1): 119-179. U. S. Coast and Geodetic Survey. 1964. United States Coast Pilot 9, Pacific and Arctic Coasts, Alaska, Cape Spencer to Beaufort Sea. U. S. Department of Commerce, Washington, D. C. 347 p. U. S. Coast and Geodetic Survey. 1965. Tsunami, The Story of the Seismic Sea-Wave Warning System. U. S. Department of Commerce. Washington, D. C. 25 p. U. S. Coast and Geodetic Survey. 1970. Tidal Current Tables: Pacific Coast of North America and Asia. U. S. Department of Commerce, Washington, D. C. 254 p. U. S. Navy Hydrographic Office and Weather Bureau. 1961. Climatological and Oceanographic Atlas for Mariners. VII, North Pacific Ocean. U. S. Department of the Navy and U. S. Department of Commerce, Washington, D. C. Wickett, W. P. 1966. "Fofonoff Transport Computations for the North Pacific Ocean 1962-65; 1946-49; 1966. J. Fish Res. Bd. Can., M. S. Rept. Ocean. and Limnol. Nos. 218-225, 229. 92 p. Wickett, W. P. 1967. Fofonoff Transport Computations for the North Pacific Ocean 1967. Fish. Res. Bd. Can. Techn. Rept. 53. Wright, F. F. 1970. An Oceanographic Reconnaissance of the Waters around Kodiak Island, Alaska. Rept. R 70-19. Institute of Marine Science, University of Alaska, Fairbanks. 23 p. Wright, F. F. 197la. "Fjord Circulation and Sedimentation, Southeastern Alaska." Proc. Int'l Conf. on Port and Ocean Engin. Under Arctic Conditions. Trondheim and Tromso, Norway. pp. 65-70. 89 Wright, F. F. 1971b. "Suspension Transport in Southern Alaska Coastal Waters." Preprints, 3rd Annual Offshore Technology Conference. Houston, Texas. pp. 235-242. Wright, F. F., G. D. Sharma, and D. C. Burbank. 1973. "ERTS-1 Observations of Sea Surface Circulation and Sediment Transort, Cook Inlet, Alaska." Sympos. on Significant Results Obtained from the Earth Resources Technology Satellite-l. V. I, Sec. B., pp. 1315-1322. 90 V. | GEOLOGY ONSHORE BEDROCK GEOLOGY Introduction The major geologic and tectonic elements of the region are long, linear arcuate belts that parallel and correspond approximately to the major physiographic provinces. The onshore geology of the region is summarized on the generalized geologic map (Figure 31). The subdivisions on the map represent groups of genetically related geologic units. A brief description of each map subdivision is included below. A correlation chart describing in more detail the individual rock units within each subdivision is shown in Figure 32. Additional details of each rock unit can be found in the appropriate references, especially Burk 1965 and Moore 1967, 1969. Also included is an index map showing sources of additional published geologic information (Figure 33). Reference can be made to these maps and reports for more details of the geology of any particular area. Extensive work by petroleum companies has produced much additional information, but most of this is proprietary information. The bedrock geology of the region can be separated into two basically different units--the Alaskan Peninsula and the Shumagin-Kodiak Shelf-- each with its own rock types, structural configuration, and geologic history (Figure 34). The nature of the boundary between these two units is unknown. It may be a fault zone that represents a former major boundary between two crustal plates, or it may simply represent a transition between shallow and deep water sedimentation. The geology of each of these units is discussed in separate sections below. Alaska Peninsula The geology of the Alaska Peninsula has been studied by many investigators since the turn of the century. One of the primary investigators has been the U.S. Geological Survey in its continual program of resource evaluation. A detailed investigation and summary of the geology was completed by Burk in 1965, and this work has become the standard reference for the area. The Alaska Peninsula part of the geologic map (Figure 31) has been generalized from Burk's tectonic map, and much of the following summary is extracted from this excellent source (Burk 1965). The "basement" rocks of the Alaska Peninsula (1)* comprise a suite of "eugeosynclinal" rocks consisting of partly metamorphosed clastic conglomerate, sandstone, shale, carbonate, and volcanic rocks of presumed Paleozoic age overlain by 5,000 to 10,000 meters of limestones, chert, clastics, and miscellaneous volcanic rocks of Permian through Lower Jurassic age. During Early to Middle Jurassic time (176 to 154 * Numbers refer to subdivisions on geologic map (Figure 31). Figure 31. Generalized bedrock geologic map, Western Gulf of Alaska. See Figure 32 for more details of rock units (from Moore 1967, 1969; Burk 1965, Barnes 1967, and Von Huene et al. 1971). LEGEND Geologic Units 1-Clastic (shale, sandstone, conglomerate), carbonate, and volcanic rocks (metamorphosed in part) of Paleozoic to Early Jurassic age - "basement." 2-Granitic plutonic rocks of mainly Early to Middle Jurassic age (contains some younger plutonic rocks). 3-Clastic rocks of Middle Jurassic to Late Cretaceous age. 4-Clastic and volcanic rocks of Tertiary age. 5-Granitic plutonic rocks of Middle Tertiary age. 6-Clastic rocks (flysch) of Jurrassic (?) to Late Cretaceous age. 7-Clastic and volcanic rocks of Triassic (?) age intruded by ultramafie bodies. 8-Granodiorite plutons of Early Tertiary age. 9-Clastic and volcanic rocks of Tertiary age. X-Recent_and active volcanoes. ----— Contact between geologic units ome §=Major faults —_—t- Major anticlinal axes 164° 162° 160° 158° 156° 154° 152° 150° Figure 31. Generalized bedrock geologic map, Western Gulf of Alaska (cont'd). “tert, ae o>” M+ 7 a KODIAK 7 TERTIARY —~ SHUMAGIN- KODIAK » PROVINCE SHELF 2? ° BEDROCK GEOLOGY 164° 162° 160° 158° 156° 154° 152° 150° to Central Alaska N. Alaska Peninsula- Kodiak and Vicinity Peninsula Lower Cook Inlet : (See above) (See apove Largely dark sh., ss., Porphyritic flows, limy concretions in breccias, tuffs (latite upper 400m. with tuff. to basalt), some and calc. sh., ss. argillite and gray- and volc. breccia in wacke (unfossil.) lower 300m9 (700m.) (+2450m. 2max.) Thin Ists, with calc. Kamishak Fm. Calc.sh sh,, containing Ist., chert, Monotis Monotis subcircularus, subcircularus_ and Cherty beds at base Halobia spp. (+600 m. (+425m, ?) 2 ? Volc. flows, breccias, tuffs, sills on iso- lated islets, Mid- Permian fossils col- lected from single Ist. (+1225m. ?) (Probably Permo-Triassic) LY Not Exposed Jurassic Uyak Fm. Black sh., green tuff, pillow ba- salts, red chert, ultramatic intrusions. Late Tr. Marine fossils. (6000 m.+) Mesozoic Alted. greenstone, volc. flows, tuffs, breccias of unknown thickness; unfossil, (Presumably Permo- Triassic) ? Not Exposed Slate, graywacke, chert, Ist., marble, calc. schist, gneiss, qtzite, mica schist. Age unknown, orob, Paleozoic arboniferous Permian Triassic 2 o m7 x 3 3 n o 2 N Figure 32. Correlation chart of geologic units, Western Gulf of Ataska (from Burke 1965 and Moore 1969). £6 v A 3 N ° un © a Staniukovich Fm, Arkosic ss., sltst. (0-600m.) Naknek Fm, Arkosic ss, sltst., cgl., clyst. (900-1500m, +) ? / / Exposed Figure 32 (continued) Map Unit 3 Staniukovich Fm, Arkosic ss., sltst, (0-600m.) Naknek Fm, Upper dark sltst. and fine-gr. ss. Lower arkosic ss, cgl. sltst. (1500-3000m. +) Shelikof Fm, sh., SS., cgl. (1600-2200m.) Kialaqvik Fm. ss., sh., some cgl. (530 m.) PARRA? (see below) Naknek Im. Arkosic ss., some cgl., tuff, Siltst. and arkose in lower part (1700m. +) Chisik Cgl. Mb. (0-120m.) Chinitna Fm, Sltst., some ss., Calc, concretions (600-90m.) ? s|Tuxedni Group. Cgl., ss., sh., sltst., ash beds (2000m.+), in- cludes Bowser, Twist Ck., Cynthia Falls, Fitz Ck., Gaikema Red Glacier Fms. plus L, Bajocian sltst., ss. Granite batholiths (176-154 m.y.) Kodiak and Vicinity Kodiak Fm.? (see above) Not exposed? (Kodiak Fm. above may be in part Jurassic) v6 AGE outhern Alaska ventral Alaska N, Alaska Peninsula - Kodiak and Vicinity Peninsula Peninsula Lower Cook Inlet aw etd f Hoodoo Fm, (0-600m.-! |Hoodoo Fm, (0-450m. +) Kaguyak Fm. Chignik Fm. (0-450m. +) (see above) Quartz diorite plutons ‘ert- FS ? ? Kodiak Fm. Slate and greywacke 7 § Chignik Fm, {0-600m. (0-1400m. +) (graded beds). Late Cretaceous Coal Valley Mb. Coal Valley Mb. (Maestrichtian) Inoceramus. (0-300m. +) (0-150m. +) (Approx. 30,000 m.) Cretaceous Map Unit 3 Limestone (0-150m. +) Staniukovich Fm. Arkosic ss., and sltst. (0-600m. +) Staniukovich Fm, Arkosic ss, and sltst. (0-600m, +) ZO1C Figure 32 (continued) S6 SOUTHERN ALASKA CENTRAL ALASKA PENINSULA PENINSULA Unconsolidated flu- Unconsolidated flu- vial and glacial de- vial and glacial de- posits(0-140 m.) posits (0-140 m, < Bear Lake FM ~~ (1500 m.+ m.+) ? N. ALASKA PENINSULA-]| Kodiak and Vicinity LOWER COOK INLET Unconsolidated flu- Unconsoliated flu- vial and glacial de- g vial and glacial de- posits (0-140 m.) posits (0-140 m.) Tugidak Fm, Marine clastic RX Bear Lake FM (900-1500 m.+) Narrow Cape Fm. Cenozoic 2. f Sitkinak Fm. 7? > 2 (1500 m.) a Gia a——_-9___9 Saetae Sele! ‘ae Meshik FM, = ae Sitkalidak Fm. @ Ole | as (1500 m.+) § >Y (3000 m.) ~ jal 30 ae EG x Da a Rock F ? Tolstoi FM. 6g 8 B ost Roc ; m. (1500 m.) | m.) Zoe Ho —_ 8.000 B.2) 4 (see below) | ee ton | | eee pelpy) ll (See ~— Figure 32 (continued) 96 Figure 33. Index map of pertinent geologic studies, Western Gulf of Alaska. Numbers refer to areas outlined on map. See literature cited at end of section for more details on references (from Burk 1965 and Moore 1967, 1969). 1. Atwood 1911 2. Burk 1965 3. Capps 1937 4. Grantz 1963 5. Keller and Reiser 1959 6. Kennedy and Waldron 1955 7. Knappen 1929 8. Mather 1925 9. Moore 1967, 1969 10. Smith 1925 11. Smith and Baker 1924 12. Waldron 1961 so 150° 164° 162° I60° 158° 156° 154° 152 59° Figure 33. (continued) 58° 57° 56° 56° 55° 54° 7 150° 164° 162° 160° 158° 156° 154° 152 86 & ALASKA g PENINSULA KODIAK — SHUMAGIN SHELF = <— KODIAK MESOZOIC PROVINCES ¢———KODIAK TERTIARY PROVINCE—————> a «4 Katmai Shelikof Kodiak I. Fault Late Tertiary i Basin Arch SL aad e-—-77 Oceanic Layer = © — 2 0 A of oo as \ “$s = _— Mantle ? 2 a — = \e 2 - € S = = = f ~~ —-" Lo- = v oo 6 a 20 a ? = Figure 34. Generalized cross-section, Western Gulf of Alaska (adapted from von Huene et al. 1971 and von Huene 1972). 100 million years--m.y.--ago), these rocks were intruded by the granitic rocks (2)* that comprise the large Alaska-Aleutian Range batholith. This batholith extends from Becharof Lake on the Alaska Peninsula to the Talkeetna Mountains north of Anchorage. (Reed and Lanphere 1973). Uplift of these "basement" rocks (1 and 2*) provided the source for a thick, continuous sequence of shallow and deep marine clastic sedimentary rocks of Middle Jurassic through Lower Cretaceous age (3)*. Following a period of regional uplift and erosion, another sequence of shallow and deep marine clastic sediments was deposited during Upper Cretaceous time (included with unit 3*). The Tertiary rocks of the area (4)* are characterized by a thick sequence of shallow marine and nonmarine clastics mixed with a variety of volcanic rocks (flows, sills, dikes, tuffs, etc.). During mid-Tertiary time all of these rocks were intruded by another series of granitic plutions (5)*. Extensive volcanic activity has continued to the present as evidenced by the chain of recent and active volcanoes extending along the Peninsula. See Burk (1965) for a more detailed description of the geologic history of the area. The structural geology of the area is characterized by broad, anticlinal fold complexes paralleled by steeply dipping faults (Figure 31). The northern part of the Peninsula is dominated by the Bruin Bay fault, a steeply dipping reverse fault that separates geologic terranes (1)* and (2)* from terrane (3)*. To the southwest the geological structure is dominated by large en echelon anticlinal complexes containing highly deformed rocks as young as Late Tertiary. The major faults are intimately associated with these anticlinal folds. No major strike-slip faults are known on the Alaska Peninsula. Except for early movements on the Bruin Bay fault, most of the major tectonic features of the Peninsula are thought to have formed during Late Tertiary to Recent time (Burk 1965). Only the major tectonic elements (folds and faults) are shown on the geologic map (Figure 31). Shumagin-Kodiak Shelf The geology of the Shumagin-Kodiak Shelf area is much less known due to fewer geologic studies and less exposed land area. Early mineral investigations and a detailed reconnaissance study by Capps (1937) provided the only geologic information of the Kodiak area until more recent studies by the U.S. Geological Survey (Moore 1967 and 1969, Jones and Clark 1973). The reports by Moore (1967, 1969) were used in the compilation of the Kodiak portion of the geologic map (Figure 31) and the correlation chart (Figure 32). A brief report by Grantz (1963) provides a general geologic description of the Shumagin Islands, and Moore (1972, 1973) has made a more recent study of the sedimentary rocks on the Shumagin and Sanak Islands. The Shumagin-Kodiak shelf separates the Alaska Peninsula from the Aleutian Trench, and its geology is somewhat distinct from the Peninsula (Figure 31). The core of the shelf is a thick sequence of Jurassic (?) * Numbers refer to subdivisions on geologic map (Figure 31). 101 to Cretaceous, deep marine, partly-metamorphosed sandstone and mudstone (flysch deposits) that form a belt of rocks extending from the Sanak Islands through Kodiak to the Kenai Mountains (6)* (Burk 1965, Jones and Clark 1973, Moore 1967, 1969, Moore 1972, 1973). Similar rocks extend further north, forming the core of the Chugach Mountains, and may also extend west in the subsurface along the continental margin of the Bering Sea (Burk 1965, Moore 1973). These rocks apparently are the deepwater (trench or continental rise) equivalents of the Jurassic-Cretaceous sediments on the Alaska Peninsula (3)*. Lying northwest of these rocks, presumably in fault contact on Kodiak Island and in the Kenai Mountains, is a belt of Triassic (?) volcanic rocks, deepwater clastic sediments, and ultramafic bodies (7)*. All of these rocks have been intruded by granitic plutions of early Tertiary age (8)*, which occur on the Sanak Islands, Shumagin Islands, Semidi Islands, as well as forming much of the mountainous terrain of the Kodiak Island group. Uplift of all of these rocks provided the source for a series of deep marine to nonmarine Tertiary clastic sediments and volcanics that are now partly exposed along the southeast flank of the Kodiak Islands (9)*. The structural geology of the Shumagin-Kodiak shelf is much more complicated than the Alaska Peninsula and is characterized by highly complex and irregular folding and faulting. The strike of the beds and the faulting generally parallels the continental margin and the beds all generally dip to the northwest. An exception is on the Sanak Islands where the beds have a northwest strike. On Kodiak Island unit 6* is separated from unit 9* by one of several steeply dipping faults that represents a zone of differential uplift between Kodiak Island and the adjacent continental shelf. OFFSHORE BEDROCK GEOLOGY Introduction Much less is known about the bedrock geology of the offshore area than the onshore area. The offshore portion of the geologic map essentially represents an extrapolation of onshore geologic belts (Figure 31). This has been supplemented by some marine geological and geophysical studies by the U.S. Geological Survey (Barnes 1967, von Huene et al. 1971, von Huene 1972) and the University of Alaska Geophysical Institute, as well as several holes drilled during Leg 18 of the JOIDES Deep Sea Drilling Program (DSDP) (Kulm et al. 1972). The offshore geology probably is much better known as a result of extensive petroleum company geological and geophysical surveys, but this informa-— tion is proprietary and is not presently available. Alaska Peninsula Basement rocks exposed on the Alaska Peninsula (1)* probably extend offshore in the subsurface and may be, in part, equivalent to the * Numbers refer to subdivision on geologic map (Figure 31). 102 Triassic (?) rocks found along the northwest side of Kodiak Island and on the Kenai Peninsula (7)*. The relationship between these units still is unknown (Figure 34). The Middle Jurassic to Cretaceous rocks of the Alaska Peninsula (3)* also probably extend offshore at least to the boundary between the Alaska Peninsula and the Shumagin-Kodiak Shelf units. They may represent lateral equivalents of the deepwater flysch sediments on Kodiak Island and adjacent areas (6)*. The distribution of the Mesozoic rocks offshore is only postulated, since they are partly masked by overlying Tertiary basins filled with volcanic and clastic sedimentary rocks (9)*. The exact distribution of the Tertiary basins is not available knowledge, but their presence is inferred from onshore geology and regional gravity and magnetic data (Barnes 1967 and University of Alaska Geophysical Institute unpublished reports) (Figures 35, 36 & 37). The Tertiary rocks of the Cook Inlet Basin may extend south into Lower Cook Inlet, but if they do they probably are quite thin. They may even connect with another Tertiary basin in Shelikoff Strait, which is inferred from adjacent onshore Tertiary rocks on the Alaska Peninsula and regional geophysical surveys (Figures 35, 36 & 37). The presence of Tertiary rocks on all the islands off the southern Alaska Peninsula suggests that these rocks also cover most of the offshore area between the mainland and the outer Shumagin Islands. Data on the structural geology of the offshore area are not now available, but presumably the broad onshore en echelon anticlinal folds and faults extend offshore for some unknown distance. Superimposed on these trends is the inferred synclinal Tertiary trough along Shelikoff Strait. Shumagin-Kodiak Shelf The Shumagin-Kodiak Shelf essentially consists of two main geologic provinces--the Kenai-Kodiak Mesozoic province and the Kodiak Tertiary province (von Huene et al. 1971). The presence of similar Mesozoic rocks with similar structural trends on the Sanak Islands, outer Shumagin Islands, Kodiak Islands, and the Kenai Peninsula (units 6, 7, and 8)* suggests that these rocks form a continuous belt that extends the entire length of the shelf. The outcrop areas represent uplifted portions of this belt. The northwest edge of the belt is delineated by the Triassic (?) volcanic, sedimentary, and ultramafic rocks (7)* which extend offshore as a narrow gravity and magnetic high (Figure 35, 36 & 37). This Mesozoic belt is defined on the southeast by a fault zone (see below), although the Mesozoic rocks probably extend further offshore beneath the outer shelf in the deep subsurface as a thick sequence of deformed sedimentary rocks (Figure 34) (von Huene et al. 1971). * Numbers refer to subdivisions on geologic map (Figure 31). 160° 158° 156° 154° 152° 150° 148° 146° 144° CONTOUR INTERVAL = 20 MGALS - MID-MAP SCALE IN STATUTE MILES 220 4060 _80_190 60° 58° 57° 56° Figure 35. Generalized simple Bouguer gravity in southern Alaska 54° (from Barnes 1967) 160° 158° 156° 154° 152° 150° 148° 146° 144° 61° 60° 59° 58° 57° 56° 55° 54° £or Figure 36. Generalized gravity map, Shelikof Strait area. Con- tour interval - 10 milli- gals (from J. Kienle, Geo- physical Institute, Univ- ersity of Alaska,Fairbanks. Personal communication. 104. fos Figure 37. Generalized magnetic map, Shelikof Strait area. Con- tours in gammas (from D. Stone, Geophysical Insti- tute, University of Alaska, Fairbanks. Personal Com- munication). 106 Superimposed on this Mesozoic belt in the offshore area are several Tertiary basins that probably mask the distribution of the older rocks. These basins, like the one in Shelikoff Strait, are inferred mostly from geophysical data (Figure 35). One seismic line by the U.S. Geological Survey shows a thick (4 km.) section of truncated strata that appears to form the southeast flank of the basin southwest of Kodiak (Figure 38a) (von Huene et al. 1971). The second main geologic province of the Shumagin-Kodiak Shelf is the Kodiak Tertiary province, which consists of a thick sequence of Early to Late Tertiary, continental to deep marine, clastic sedimentary rocks. Most of the province is covered by the sea, while only a small portion is exposed onshore along the southeast shore of Kodiak Island and the Trinity Islands (9)*. The offshore portion of the province surrounding Kodiak has been only partially delineated by geological and geophysical surveys of the U.S. Geological Survey and holes drilled during Leg 18 of the D.S.D.P. (Shor 1962, von Huene et al. 1967, von Huene and Shor 1969, Shor and von Huene 1972, von Huene et al. 1971, von Huene 1972, von Huene et al. 1972, Hulm et al. 1973). Most of the remaining part of this section is summarized from these studies. The Kodiak Tertiary province probably extends northeast to connect with the Gulf of Alaska Tertiary province, but its extent to the southeast beyond Chirikof Island along the continental margin is presently unknown. The rocks of this province may even extend west and be equivalent to the rocks forming the Tertiary basin southwest of Kodiak and the Trinity Islands. For the purpose of discussing the geology, the Kodiak Tertiary province can be divided into five separate subprovinces--a fault zone, a late Tertiary basin, an arch at the edge of the continental shelf, the continental slope, and the Aleutian Trench (Figures 31 and 34). The province is flanked on the northwest by a zone of folds and faults up to 30 km. wide that parallels the continental margin from Prince William Sound at least as far south as Kodiak Island (Figures 31, 34 and 38b). The zone separates the uplifted Kenai-Kodiak blocks from a subsiding Late Tertiary basin on the continental shelf. A portion of the fault zone occurs subaerially along the southeast coast of Kodiak Island. The faults are characteristically steep and generally shorter than 30 km. in length, although some extend over 50 km. Some faults reach to the sea floor, forming fault scarps with a sharp bathymetric expression, indicating the recency of the faulting. Some movements probably took place during the 1964 Alaska earthquake, as this zone corresponds roughly to the area of most intense aftershock activity and strain release. A basin filled with up to 3 to 4 km. of Late Tertiary sediments has been formed by the depression of an area seaward of the fault zone off Kodiak. The age of the basin fill is inferred to be Late Tertiary A 2 4 B ° 00 “2 CD ONEEN 1G 7S 04 sec. ort O24 68 SNoe |. KM a. Thick Tertiary basin southwest of Kodiak 2 °o w a z oO Vv y a uu 2 = > < = fe) 2 z oo ey 20 KILOMETERS > °o d. Aleutian trench east of Kodiak b. Fault zone east of Kodiak Figure 38. Seismic tracings, Shumagin-Kodiak Shelf, Western Gulf of Alaska (from von Huene et al. 1971, Piper et al. 1973 and von Huene 1972). Lol 59° 57° 55° 54° 164° 162° 160° 158° 156° 154° 152° Is0° ! : i Figure 38 (cont'd). Seismic tracings, Shumagin-Kodiak Shelf, Western Gulf of Alaska. Location of sections (from Piper et al. 1973, von Huene et al. 1971, and von Huene 1972). eel ° 100 KM o 2) ge a FE on OSs g: 3 . ° hia Do | Ash | Oo D eo Qe foo" pote . / of Nae H? ai _ wae |_--60007 164° ‘ 162° 160° 158° 156° 154° 152° 150° 58° 57° 55° 54° Plot 108 © because of Miocene and Pliocene strata exposed on the truncated seaward flank of the basin. The basin may extend north to connect up with a similar basin lying north of Middleton Island, or it may represent another isolated basin as inferred elsewhere on the shelf. Underlying this Late Tertiary basin is a thick section of presumably lower Tertiary rocks deposited earlier in an older basin along the continental margin (Figure 34). The Late Tertiary basin is flanked on the southeast by a broad arch that forms the edge of the continental shelf (Figure 34 and 38c). Although the arch is discontinous at the surface, it probably continues as a deep structure as evidenced by geophysical data along the continental margin. The arch represents a zone of continuous deformation involving tilting, folding, faulting, and truncation during periods of both uplift and subsidence. The arch is characterized by large anticlinal structures (Figure 38c). There apparently has been a net tectonic uplift, as indicated by the overall geometry and by the presence of very deepwater microfossils now found at only 20 fathoms depth. This arch in places has a topographic expression on the sea floor and apparently was above water as one or more islands at various times, as indicated by the local truncation of beds. Middleton Island to the north is a present day example, and Albatross Bank probably was exposed during glacial periods of lowered sea level. Truncated rocks as old as Miocene-Pliocene have been sampled along the arch off Kodiak, while truncated Pliocene-Pleistocene rocks are exposed on Middleton Island. The continental slope is characterized by a rugged morphology composed of benches, peaks, canyons, and steep slopes (Figure 38c). The benches and peaks probably represent rotated blocks, slumps, or slides resulting from massive downslope movements of the slope. This downslope movement probably is caused by rapid deposition during glacial periods combined with continued tectonic uplift and oversteepening along the shelf break arch and upper slope. Seismic studies suggest that the slope consists of highly deformed Tertiary sedimentary rocks. Cores from holes 181 and 182 of D.S.D.P. Leg 18, however, indicate that the lower part of the continental slope consists of uplifted and tectonically deformed deepwater sediments as young as Pleistocene. The present Aleutian trench is a very young geological feature that formed in Late Tertiary time and may be even as young as Pleistocene. It is filled by two stratified units (Figure 38d). Overlying an acoustic basement of basalt is a landward dipping sequence of abyssal plain sediments deposited during Miocene to Pleistocene time. Lying on these sediments is a wedge of horizontal Pleistocene turbidity current sediments 20 to 30 km. thick filling the trench. 109 GEOLOGIC HISTORY Summary The Paleozoic geologic history of the region is generally unknown, but apparently consisted of widespread deposition of clastic sediments, volcanics, and limestones at least in late Paleozoic time. Similar deposition continued through lower Jurassic time and culminated with intrusion of the large granitic batholiths that form the backbone of the Aleutian-Alaska Range. During the remainder of the Mesozoic Period, shallow to deepwater clastic sediments were deposited in the Alaska Peninsula region, while deepwater clastic sediments were deposited in an adjacent basin or continental slope-continental rise setting to the southeast. The latter rocks were then intruded by another sequence of granitic batholiths in early Tertiary time, and the whole area was uplifted to form the present continental shelf. Continued subsidence and deposition in this shelf area, plus continual volcanism during Tertiary time, resulted in an enormous thickness of Tertiary marine to continental clastic sediments and volcanics both on the Alaska Peninsula and the shelf. During mid-Tertiary time, these rocks were intruded by a series of quartz diorite plutons along the Peninsula. Of the five periods of deformation affecting the area, three were associated with plutonic intrusion and involved only broad structural warping, as did the mid-Cretaceous deformation. The major deformation of the area has been fairly recent (post-Miocene) and quite severe, producing essentially all of the structural detail (folds and faults) now exposed. The area apparently still is one of active tectonism as indicated by deformation associated with recent earthquakes, the chain of active volcanoes along the Alaska Peninsula, and the numerous earthquake epicenters that have been recorded in the area. Since this Late Tertiary to Recent period of geologic history had such an influence on the region, it is discussed in more detail below, especially with regard to new theories of plate tectonics. Late Tertiary Geologic History and Plate Tectonics The plate tectonic theory is a unifying concept that attempts to combine seafloor spreading, continental drift, crustal structures and deformation, and world patterns of seismic and volcanic activity all together into one coherent picture. It assumes that the entire surface of the earth comprises a series of internally rigid but relatively thin (50-150 km.) lithospheric plates that are continuously in motion with respect to each other (Figure 39a). There are perhaps half a dozen major plates. Virtually all seismicity, volcanism, and tectonic activity is localized around plate margins and is associated with differential motion between adjacent plates. There are basically three types of plate boundaries: (1) Areas such as active oceanic ridges where new oceanic crust is being created and plates are moving away from each other; (2) areas where plates simply move past one another (like the San Andreas fault zone of California), and (3) areas along trenches where one plate slips down under the margin of another and surface area is destroyed. KURIL. TRENCH JAPAN TRENCH PLATE NEW HEBRIDES TONGA TRENCH ILS“) Subduction Zones ~27~ Transforms ~—s._ Md-Ocean Ridges (spreading centers) ZONE OF TECTONK, VOLCANIC AND SEISMIC ACTIVITY ———- AK. PENINSULA ANDESITIC SEAFLOOR OCEANIC MiD- OCEAN SEDIMENTS CRUST. RIDGE xn °O pees SL Ty 7 G7 vty 77 SASAlT 7 * — MOHO, ~897,— * o — — \ uo 7 OF SPREADING OCEANIC PLATE ~g 06 _——— 100 ——"” MANTLE FORMATION OF NEW OCEANIC 1so CRUST Vila 4S PARTIAL MELTING OF OCEANIC Z Y SEDIMENTS ANDO CRUST Z / ‘¥ 200 / B. Figure 39, Schematic diagrams showing major elements and mechanisms of plate tectonics theory, Pacific area. A. Map showing major crustal plates as defined by zones of seismicity, volcanism and active tectonism. B. Cross section showing mechanisms as applied to southern Alaska. 110 111 According to the plate tectonic theory, the Western Gulf of Alaska with its seismicity, young deformation, and active volcanism landward of a trench is considered a typical example of the third type of plate boundary involving the destruction of an oceanic plate beneath a continental zone along a subduction zone or Benioff Zone (Figure 39b). It has been postulated that the Pacific Plate is being underthrust under the American Plate along the Aleutian Trench at a rate of about 6 cm./yr., a process that has been going on since at least Late Tertiary time and maybe longer (Atwater 1970, Pitman and Hayes 1968). Recent evidence from D.S.D.P. Leg 18 suggests a fairly young age for that portion of the trench off Kodiak (Miocene or possibly as young as Pleistocene) (von Huene 1972). This model of a fairly recent initiation of underthrusting explains very satisfactorily many of the characteristics typical of the region, such as: (1) The intense Late Tertiary to Recent tectonic deformation, folding and faulting, including deformation resulting from the 1964 earthquake; (2) the uplift of the mountains now surrounding the Gulf of Alaska that began in Miocene time and is continuing today; (3) glaciation that began in Miocene time and became intense 3 to 4 million years ago partially as a result of the uplift of the mountains; (4) the great increase in volcanic activity about 2 to 5 million years ago that probably represents the initial development of the present Alaska Peninsula volcanic chain; (5) the apparent young age of sediments in the Aleutian Trench; (6) the seismic activity; and (7) presence of uplifted and tectonically deformed deepwater Pleistocene sediments on the lower slope. The Benioff Zone does not manifest itself at the surface as a single shear zone emerging at the trench, but apparently the stresses are redistributed at the surface along the entire continental margin as a diffuse zone of deformation (von Huene 1972, von Huene et al. 1972, Kulm et al. 1973). This is well demonstrated by the distribution of aftershocks following the 1964 earthquake. ONHORE SURFICIAL GEOLOGY Introduction There have been no detailed studies of the onshore surficial geology in the study area. Most geologic studies simply have grouped the surficial deposits as alluvium (Qal), and no attempts have been made to subdivide them into more specific genetic or descriptive units. Information on the distribution of this alluvium can be obtained from the more detailed geologic maps covering the area (Figure 33) and from overlays prepared by the Resource Planning Team of the Joint Federal- State Land Use Planning Commission for Alaska. 112 An excellent overview of the surficial geology can be obtained, however, from the map "Surficial Geology of Alaska," prepared by the U.S. Geological Survey (Karlstrom et al. 1964). This excellent map presents the generalized distribution of various genetic units for the entire state. A slightly more generalized version of this map covering just the study area is presented here (Figure 40). The distribution of surficial deposits on this map generally reflects the influence of two main agents or processes--glacial-fluvial activity and volcanic activity. Glacial-Fluvial Activity Pleistocene time was characterized by repeated glaciations that involved all the mountain ranges in the area as well as the adjacent lowlands. During the last major glacial advance (Naptowne), sea level was lowered and ice probably covered much of the continental shelf, possibly as far as the shelf edge (Coulter et al.1965). Only one small area on Kodiak Island (known as the Kodiak Island Refugium) is known to have escaped glaciation (Karlstrom and Ball 1969). Most of the mountainous upland area is characterized by erosive features produced by glacier scour--aretes, cirques, U-shaped valleys, etc. Very little glacial debris now remains except in some of the upland valleys. These remaining deposits generally are thin, and a high percentage of bedrock is exposed (Figure 40). Some fairly large glaciers still remain on some of the higher peaks of the Alaska Peninsula-- Shishaldin, Veniaminof, Katmai, and Douglas--and many smaller cirque glaciers occur on many of the other peaks on both the Peninsula and Kodiak Island. Most of the material eroded from the mountains during glacial periods of lower sea level probably was deposited on the continental shelf or beyond on the continental slope. This is supported by the rapid deposition in the Aleutian Trench of a thick section of Pleistocene sediments that had been supplied from the slope (Kulm et al. 1973, Piper et al. 1973). The present day, rugged and precipitous, fjord indented coastline is a zone dominated by aggressive wave erosion, and deposition is generally limited to narrow beaches, spits, and bars between rocky headlands. Lowland areas, including stream valleys, actually form a relatively small percentage of the land. These areas are mostly covered by glacial-fluvial deposits consisting of glacial moraines, glacial outwash, modern floodplain and adjacent terrace deposits, and even proglacial lake deposits, such as those found on southwest Kodiak Island (Figure 40). Some eolian deposits, including sand dunes as well as some older coastal deposits, also occur along the coastline. Figure 40. Generalized surficial geology, Western Gulf of Alaska (Adapted from Karlstrom et al. 1964). LEGEND Map Units 1 - Existing glaciers. 2 - Glacial moraines and associated drift, modified to varying degrees. 3 - Glacio-fluvial deposits--outwash and valley-train deposits along glacier fronts and recent moraines grading into fluvial deposits further down-valley. 4 - Fluvial deposits--floodplain, terrace, and alluvial fan deposits. S - Coastal deposits consisting of beaches, spits, bars, deltas, and interstratified alluvial and marine sediments. 6 - Coarse- to fine-grained undifferentiated deposits asso- ciated with moderate to steep-sloped mountains and hills with many bedrock exposures. 7 - Undifferentiated deposits with a high percentage of vol- canic rock particles, ash, and pumice flanking volcanic cones and peaks of Quaternary and Tertiary age. 8 - Discontinuous alluvial deposits overlying dissected un- consolidated, semiconsolidated, and locally consolidated silt, sand, and gravel of Tertiary and younger age. 113 1p ial Gulf suriic G 3 = o 3 5 2 “ alized Ologs, Western 115 Volcanic Activity Quaternary and Recent volcanic activity also has contributed much surficial material to the area. Large volcanic cones that often rise above the general height of the Aleutian range have been built by volcanic processes. In addition, great quantitities of ash and other ejecta have been supplied to the surrounding area, either by direct fall or indirectly by streams, mud flows, or other mechanisms of downslope movements. The generalized distribution of some of the major deposits flanking some of the major volcanic centers is shown on Figure 40. The most significant contribution of volcanic material in historic time came from the 1912 eruption of Katmai Volcano, one of the largest eruptions ever recorded. This eruption deposited a blanket of ash over much of the northern Peninsula, and almost a foot fell on parts of Kodiak Island over 100 km. away (Figure 41). Most of the soils of the area and sediments on the sea floor reflect this blanket of ash. Soils The general distribution and types of soils in Alaska have been summarized by the U.S. Army Corps of Engineers (1961), and a generalized version of this map for the study area is included here for reference (Figure 42). A reconnaissance soil survey of the state too detailed to present here has recently been completed by the Soil Conservation Service (Rieger 1973). Maps have been finalized but soil descriptions are still in note form. This survey is not expected to be published formally for several years, but the data can be inspected by contacting the Soil Conservation Service, Palmer, Alaska or the Resource Planning Team of the Joint Federal-State Land Use Planning Commission, Anchorage. Most of the area (more than 60 percent) is covered by coarse- grained, shallow rubble and sandy, gravel soils characteristic of mountain areas with numerous bedrock exposures. Most of the volcanoes are flanked by volcanic soils, while deeper sand and gravel soils occur along most of the major drainages. Mixed soils also occur in places overlying relatively unconsolidated Tertiary rocks, such as the Trinity Islands. Detailed soil surveys in the study area are available only for one area in northeast Kodiak Island (Reiger and Wunderlich 1960). Soils of this area generally fall into two groups: (1) Those on steep to rolling uplands, and (2) those on nearly level to gently sloping valley bottoms, including alluvial plains and terraces. Common to the upper part of all these soils is the volcanic ash layer deposited from the 1912 Katmai eruption (Figure 41). This layer makes the soils quite acidic. The soils of steep and rolling uplands make up the majority of soils in the area and include large areas of bedrock. The soil beneath the ash layer is typically a dark reddish-brown, silt loam, which is 160" EXPLANATION \ | amas Line ef equal ash depth, in feet \ @c-7 t Location ef sample dredged by Menard —--+ nn ns / 0.25 5075 MILES Cae SP 050 100 KILOMETERS i Te Ceo \ se Figure 41. Map showing distribution and thickness of ash erupted from Mt. Katmai, 1912 (from Wilcox 1959). 116 Figure 42. Generalized soils map, Western Gulf of Alaska (from U.S. Army Corps of Engineers 1961). LEGEND Map Units 1-Deep interbedded sand and gravel. Occur principally in alluvial fans, outwash aprons, floodplains, and river terraces bordering morainal complexes and along major drainage lines. 2-Deep silty sandy gravel with boulders. Occur principally in hummocky, end-, lateral-, and ground-moraine complexes in lowlands bordering the rugged mountain ranges. Peat and highly organic silt in depressions. 3-Shallow rubble and sandy gravel. Occur principally in fluvial, glacial, and colluvial deposits associated with rugged, steeply- sloping mountain areas. Numerous bedrock exposures. 4-Deep interbedded silt, sand, and gravel. Occur principally in mixed marine and terrestrial deposits in flat- to gently-sloping coastal plain areas. Peat and highly organic soils in depressions and abandoned stream channels. 5-Shallow to deep interbedded silt, sand, and gravel. Occur principally in discontinuous eolian, fluvial, and glacial deposits mantling upland surfaces and hills underlaid by thick deposits of uncemented to cemented soft bedrock of bedded silt, sand, and gravel. 6-Shallow to deep volcanic silt, sand, and gravel. Occur principally to eolian, alluvial, colluvial, and glacial deposits mantling volcanic peaks, cones and lava fields. 117 160° T T T T T 59° Figure 42 (cont'd). Generalized soils map, Western Gulf of Alaska (from U.S. Army Corps of Engineers 1961). 58° 57° 4 A 2d __ a > fo 64 al ee al __ _—6000 a —— a 164° 162° 160° 158° 156° 154° 152° 150° Ril 119 very rich in organic matter and ranges from 1 m. to a few cm. thick, depending on the steepness and height of the slope. These soil areas generally are well suited for grazing; portions of the lower slopes, if adequately fertilized, are suitable for seeding grass for hay and silage. Erosion potential is high on the moderate to steep slopes, and their use for cropping and transportation are limited. Soils of the valley bottoms are typically better drained than those of the rolling uplands. Below the ash layer, they consist of a silt loam that overlies glacial-fluvial deposits of coarse sand and gravel. If adequately fertilized, these soils also are suitable for seeding grass for hay and silage. Although these soils could be made suitable for other crops by fertilizing and mixing the ash with underlying materials, the area is generally too cold to adequately mature crops. Since much of the terrane found throughout the study area is somewhat similar to that in northeast Kodiak, the detailed description of the soils in this area by Rieger and Wunderlich (1960) can generally be applied to the rest of the area. The only noticable difference might be the presence or absence of the ash layer deposited from the 1912 Katmai eruption. OFFSHORE SURFICIAL GEOLOGY Introduction The distribution and composition of bottom sediments in the study area display considerable variation, which is due in part to (1) varying relief on the sea bottom, (2) different hydrodynamic regimes, and (3) different sources supplying different size materials. The sediments mainly consist of terrigenous material, with a high volcanic component in places and local concentrations of organic material (shell debris) (Figure 43). The only extensive work on bottom sediments of the area has been conducted by the Soviets as part of their continuing investigations of the fisheries of the Northeast Pacific. (Gershanovich et al. 1964, Gershanovich 1968, 1970). These studies were mainly reconnaissance surveys covering large areas, and the data presented are highly generalized. Much of the following discussion is taken from these excellent sources. This information has been supplemented by additional investigations carried out by the Institute of Marine Science, University of Alaska, Fairbanks, and the U.S. Geological Survey. The National Ocean Survey nautical charts for the region also provide general information on the nature and distribution of bottom sediments. | Vy tl ti} Figure 43. Sketch map of major types of sediments on the bottoms of the Bering Sea and Gulf of Alaska: 1 - terrigenous; 2 - glacial-marine; 3 - vulcanogenic; 4 - slightly carbonate and carbonate (tests, foraminiferal, and others); 5 - slightly siliceous (silceous sponges and diatomaceous); 6 - siliceous (diatomaceous); 7 - deep-sea brown; 8 - mixed (from Gershanovich 1970). O2T 121 Shelf Sediments Contemporary sediments on the shelf are generally quite thin and form an irregular veneer no more than tens of meters thick. The sediments consist mostly of terrigenous material eroded from the adjacent mountain areas during glacial periods and deposited by glacial-fluvial processes during lower stands of sea level. Most of the material probably was carried across the shelf and deposited at the shelf edge and on the continental slope. Determining the actual extent of glaciers and the distribution of glacial material on the Kodiak shelf is still problematic. Earlier workers believed that the topographic highs or banks at the continental margin (e.g., Albatross Bank) were buildups of morainal material and represented the extent of the last glaciation (Capps 1937, Karlstrom 1964). More recent seismic studies, however, suggest that this topographic feature has structural and erosional features and may represent tectonically uplifted areas (von Huene 1966). Sampling of sediments off Kodiak by Wright (1970) indicated no evidence of coarse morainal material at the shelf edge. Not much work has been done yet to positively identify submarine glacial features using high resolution seismic techniques, although this has been done with limited success in a published study off Nuka Bay (von Huene 1966) and an unpublished study by the U.S. Geological survey off Kodiak.2 This latter study suggests that an ice sheet extended across the shelf to within about 10 km. of the crest of Albatross Bank, while the trough bisecting Albatross Bank probably contained a valley glacier that extended to the continental slope. The sediments on the shelf also contain varying amounts of volcanic debris supplied by the Katmai eruptions and other volcanic processes. Fine-grained glacial debris brought in from Cook Inlet also may be making a significant contribution. All of these sediments are now being reworked and redistributed by contemporary marine processes. Along the nearshore parts of the shelf, the sediments are quite variable. Abundant coarse material is being deposited along beaches and adjacent to rocky headlands, reefs, and skerries. Finer sands and muds, however, are being deposited in the deep bays and fjords. The plateau-like areas generally are covered with a thin veneer of pebbles, gravel, and sand (Figure 44a). Similar sediments also occur on the banks and shoals, but are usually even thinner and often more poorly sorted and coarser-grained. They include pebble-gravels, boulders, and rock fragments that are commonly overgrown with organisms. lyr. Wright, Marine Geologist, Marine Advisory Program, University of Alaska, Anchorage, Personal communication. 2R. von Huene, Marine Geologist, U.S. Geological Survey, Reston, Va. Personal communication. 122 A. Sketch map of the distribution of dominant fractions in Recent sediments in the Gulf of Alaska sand and coarse sands 2— coarse silty 3 fine silt; 4 = petite B, oketeh niap oot the distabution of particles <0 01 nim (petite) im Recent sediments in the Gull of Alaska, Su “hou wto bas Ih todd; 4-40 to 10; 6 => 10 Figure 44, Size distribution of Recent sediments, Gulf of Alaska. A. Distribution e of dominant fractions; B. Distribution of pelite (from Gershanovich et al. 1964). 123 Accumulations of shell debris are commonly found, particularly along the shelf edge banks (e.g., Albatross Bank) (Figure 43). At many places along the banks, sediments are completely absent and bedrock is exposed on the sea floor, reflecting the overall tectonic uplift and erosion of these areas. Bedrock is also commonly found along recent fault scarps. Some muds do occur on the shelf, especially in lower depressions. The overall mud content generally increases to the east, due mainly to greater influx of contemporary, fine-grained, glacio-marine material (Figure 44b). The distribution of sediments on the shelf appears to follow a normal graded pattern (Figure 44). Coarse sediments generally dominate down to about 70 to 80 m. Between 70 to 80 m. and 120 to 150 m., there is an increase in the content of fine sands and silts plus some clays in lower depressions. Below this depth, especially in the sea valleys like Shelikof Strait, fine-grained sediments persist (sandy mud, mud, clayey mud, plus some organic material). This graded distribution of sediment with depth probably reflects the influence of contemporary marine processes, particularly waves, on the shelf bottom. Above about 100 m., waves, especially those generated by storms, feel the bottom and winnow out finer material, which is then deposited in adjacent deeper water. The concentration of fine-grained muds in the Shelikof Strait sea valley may be, in part, contemporary material being introduced into the area by currents circulating out of Cook Inlet (Figure 45). Data on the composition of shelf sediments is somewhat limited with the Soviets providing most available information. The general distribution of various chemical parameters (iron, manganese, authigenic silica, and organic carbon) have been reported for the entire Bering Sea-Gulf of Alaska region (Figure 46), but these maps don't show much detail on the shelf area (Gershanovich 1968, 1970). The high iron content off Unimak Island and vicinity probably reflects a volcanic source for the sediments, while the higher values of organic carbon on the continental slope probably reflect the intersection of an oceanic oxygen-deficient layer with the slope. A fairly detailed analysis of the mineral compostion of the bottom sediments in the study area was conducted by Bortnikov (1970). He sampled only the coarse silt fraction of the sediments and produced a set of maps showing the distribution of various minerals (quartz, volcanic glass, and several heavy minerals) (Figure 47). These maps reflect well the volcanic and terrigenous origin of much of the sediment. These types of maps also can be useful in determining sediment dispersal patterns and locating possible subsea placer mineral deposits that have been concentrated on the shelf. Additional studies of the shelf sediments are being carried out by G. D. Sharma of the Institute of Marine Science, University of Alaska, Fairbanks. Detailed textural data, clay mineralogy, and chemical analyses are presently being determined for 39 stations around Kodiak Island plus 17 stations along the shelf between Unimak Island and north of Kodiak. 124 155° 154° 153° 152° /5/? /50° Ag FIGURE 45 COOK INLET Typical Surface Suspended Sediment & Circulation Pattern Eq <2mg/ 2-10mgA 10-20 mg// 20-100mg/ 100-1000mg/I 155° 154° 153° 152° /s/° 150° 149° (from Wright et al. 1973) 125 A. Distribution of iron (%) in bottom sediments in the far North Pacific (the Bering Sea and Gulf of Alaska): 1-—<2; 2-2-3; 3-3-4; 4-4-6; 5-56; 6-6-7; 1—>7. B. Distribution of manganese (in %) in bottom sediments in the far North Pacific (the Bering Sea and Gulf of Alaska): 1—<0,05; 2—0.05—0.10; 3~-0.10-0.50; 4—0.50—1.00; 5—>1; 6 — boundaries of areas, @ Figure 46. Distribution of chemical parameters (percentage) in bottom sediments, Gulf of Alaska and vicinity. A. Iron; B. Manganese; C. Silica; D. Organic carbon (from Gershanovich 1970). 126 C. Distribution of authigenic silica (in %) in bottom sediments in the far North Pacific Ocean (the Bering Sea and Gulf of Alaska): 1—<5; 2—5-10; 3-10-20; 4— 20-30; 5—>30. North Pacific (the Bering Sea and Gulf of Alaska): D. Distribution of organic carbon (in %) in bottom sediments in the far 1 «0.50; 2—0.50-1.00; 3—1.00-1,50; 4 — 1.50- 2.00; 5 —> 2.00. Figure 46 (continued) A. Distribution (ino) of silty material (0.1 —U.i mm) in surface sediments in the northwestern part of the Gulf of Alaska: 1—<10; 2-10-30; 3—30—50; 4—>50 B. Distribution of quartz (in %o) in the surface sediments in the northwestern part of the Gulf of Alaska: 1—<10; 2-10-20; 3—>20%. C. Distribution of volcanic lass (in %) in the surface sediments in the northwestern part of the Gulf of Alaska: 1-—<3; 2-—3-10; 3-10-30; 4—>30. Figure 47. Distribution of minerals in silt fraction (percentage) of bottom sediments, Western Gulf of Alaska. A. Silty material; B. Quartz; C. Volcanic glass; D. Heavy minerals; E. Black ore minerals; F. Hornblende; G. Clinopyroxenes. (from Bortnikov 1970). 127 D. Distribution of heavy subfraction minerals (in 7) in the surface sediments in E. Distribution of black ore minerals (in %) in the surface sediments in the north- the northwestern part of the Gulf of Alaska western part of the Gulf of Alaska: 1-<3; 2-—3-10; 3—>10. 1-<15; 2-—>15. F. Distribution of hornblende (in “s) in the surface sediments in the northwesterr G. Distribution of clinopyroxenes (in 30) in the surface sediments in the north- part of the Gulf of Alaska: western part of the Gulf of Alaska: | 1—<20; 2—>20. 1—<10; 2—>10. Figure 47. Distribution of minerals in silt fraction (percentage) of bottom sediments, Western Gulf of Alaska. A. Silty material; B. Quartz; C. Volcanic glass; D. Heavy minerals; E. Black ore minerals; F. Hornblende; G. Clinopyroxenes. (from Bortnikov 1970). 87I 129 Slope Sediments Sediments now being deposited on the continental slope are composed mostly of fine-grained, terrigenous material plus substantial amounts of volcanic material, especially in the Kodiak area (Figure 43). Small amounts of organic material, mainly forams and diatoms, also occur. As might be expected, sediments get finer-grained with depth. In general, they consist of muddy sand and sandy mud to depths of 500 to 600 m., sandy mud and mud between 600 m. and 2,000 m., and mostly clayey mud greater than 2,000 m. The slope is highly irregular and dissected, and bedrock is exposed at many places. As noted in the section above, large quantities of sediment probably were supplied to the slope during glacial periods of lower sea level. Much of this material has been or presently is being transported downslope to the trench below as evidenced by (1) seismic records showing rotated blocks that apparently are large slumps or landslides, (2) large slumps at the base of the slope, (3) thickened trench sediments at the mouths of canyons, and (4) thick sands and sandy turbidites found on the lower slope at sites 181 and 182, Leg 18, of the JOIDES Deep Sea Drilling Program (Kulm et al. 1973, Piper et al. 1973). This downslope movement probably is the result of rapid deposition at the continental margin combined with tectonic oversteepening of the slope. Aleutian Trench Sediments Sediments filling the Aleutian Trench consist mostly (about 90 percent) of sands, silts, and muds derived from a landward source, and are deposited mainly by turbidity currents flowing down canyons in the lower slope or by sliding, slumping, or creeping off the adjacent slope (Piper et al. 1973). The remaining approximately 10 percent of the sediment is supplied by abyssal plain, turbidite sedimentation and pelagic sedimentation (7 percent and 3 percent, respectively). There is no evidence of reworking of sediments by bottom currents. MINERALS Metallic The metallic mineral potential of the study area is virtually unknown, since there has been very little extensive and detailed exploration. There is enough evidence of mineralization, however, to indicate that parts of the area do have significant potential. Figure 48 summarizes the distribution of mineral occurrences in the area. The main source of data is the MF map series recently published by the U.S. Geological Survey (Cobb 1972 a-h). Additional detail on the general location of mineral occurrences can be obtained from several recently published reports by the U.S. Geological Survey (Berg and Cobb 1967, Cobb 1972, U.S. Geological Survey 1972, and Cobb 1973). Based on these occurrences, Clark et al. (1972) identified several metal provinces Figure 48. Provinces and occurrences of metallic minerals, Western Gulf of Alaska. LEGEND LY - Major metal provinces (elements of secondary importance in parentheses (from Clark et al. 1972). Cc) - Areas with high mineral development potential as identified by Resource Planning Team of the Joint Federal- State Land Use Planning Commission. Cc ») - Areas with intensive mining claim >= activity as identified by Resource Planning Team. -— C » - Areas with moderate to low mining >---- claim activity as identified by Resource Planning Team. Other mineral occurrences are from Cobb (1972a-h). x - placer deposits e@ - lode deposits 130 164° 162° 160° 152° 150° 1 T T T T~ T T T 2B Ti oS, a 50° cook iat C 50° - NX Figure 48. Provinces and occurrences eor- Cu Se 200 of metallic minerals, e Western Gulf of Alaska Au-Cu fcontinued) (Pb-Zn—Ag-W) 58° c ir se Cu, Ag Au,Pb, Zn ) r 57° o D 57° Pb,Zn,Hg Au,Ag ~@O tS S IB ~~ 7 —__ | PPs2n C fe / ° 100 KM c eee 6S) \ C Au rn? u, Pb, Zn, (7 \ ) _ Au, Ag aS CHIGNIK = 56° > 0 .y AREA } Au 77200 ~ 56° a ra f c (% ( 9) J co, Vy a! Au-Ag / ) . (Cu-Pb-Zn) \ » yy % af Ge 200 Ss “ enga Il Kop § ae) _ . 9 SOW BAS 55° Au,Ag,Cu, Pb, Zn $ Be 8 o 75 yr S 200 <7 . —— aoe . /— ZO a _ 549) a —— | 54° ~ Ke — ___-6000 — —_——— — ~ i ~ 4 a pe 1 164° 162° 160° 158° 156° 154° 152° 150° el 132 in the region--areas characterized by a distinct association and/or anomalous concentrations of a metal or metals. The Resource Planning Team of the Joint Federal-State Land Use Planning Commission also has identified several areas of high mineral potential and has outlined areas with mining claim activity; both of these areas are shown on Figure 48. Detailed data on mining claims are stored in the State Division of Geological and Geophysical Survey's computerized Kardex file. This Kardex data has also been plotted on a map of Alaska (Swainbank 1973). The location of all mining claims has recently been plotted by the U.S. Bureau of Mines on quadrangle overlays at a scale of 1:250,000. These maps are available at local Bureau offices. There are two main areas where mineral occurrences are concentrated and that have known mineral potential, the Unga Island-Chignik area and Kodiak Island. The former area actually consists of two separate areas that were connected into a proposed mineral province or belt (Clark et al. 1972). The southern portion of this area consists of mineralization on Unga Island and vicinity, indicating the presence of both a gold- silver province and a copper-lead-zinc province. There was much activity in this area at the turn of the century. Over two million dollars worth of gold and silver were produced from the now abandoned Apollo Mine on Unga Island between 1891 and 1904. Minor amounts of gold, plus silver, lead, and copper were also produced elsewhere in the area during this period. There has been only a minor amount of activity in recent years. The Chignik area also contains a gold-silver province and a cooper- lead-zinc province. There is no known production from this region, but there has been considerable activity in recent years. Several local areas are considered high in mineral potential and have had intense mining claim activity (Figure 48). Several Japanese and French companies have recently shown particular interest in a lead-silver-molybdenum prospect at Chignik and a copper prospect at Warner Bay just south of Chignik. A copper prospect near Chignik (possibly the one at Warner Bay) was reported to have been drilled in 1971 (Eakins 1972). There was no known mineral exploration in 1972 (Alaska Division of Geological and Geophysical Surveys 1973). Descriptions of earlier mineral exploration activities in this region were reported almost annually during the 1920s to 1940s in a series of U.S. Geological Survey Bulletins entitled "Mineral Resources of Alaska." No published material was found describing more recent activities. The second area where there is a concentration of mineral occurrences is Kodiak Island and vicinity. A recent open file report by the State Division of Geological and Geophysical Surveys presents an excellent summary of the geology and mineral resources of the area (McGee 1972). Gold is the main commodity found on the island. Placer deposits occur along most of the beaches and have been mined from time to time. Maddren (1919) reported that at least 150,000 dollars worth of gold was 133 extracted, but Capps (1937) estimated much more. The gold concentrations appear to be dependent on contemporary storm wave and current activity; it is doubtful that similar deposits exist very far offshore (McGee 1972) Small gold lode prospects occur throughout the island, mainly in quartz veins associated with granodiorite intrusions, dikes, and sills. These are probably the source for the placer deposits. Minor production is reported from one prospect (Berg and Cobb 1967). There has been a general lack of exploration for gold in inland areas, especially where mineralization might be expected along the flanks of the major granodiorite intrusions forming the core of the islands. Minor lode occurrences of other commodities have been reported on the island including silver, copper, lead, and tungsten. None of these appear to be commercial deposits, but they have not been explored extensively. In fact, less than 20 percent of Kodiak has been adequately prospected (McGee 1972). The presence of ultramafic complexes along the northwest coast of Kodiak in the Triassic (?) rocks, plus the occurrence of minor quantities of platinum and chromite in placer deposits, suggest that the area has a potential for platinum, chromite, and nickel (Figure 48). These complexes are part of a long narrow belt of ultramafic bodies that probably extends from Kodiak to beyond the Canadian border (Clark and Greenwood 1972). Extensive mineralization has been found in many of the bodies along this belt. For example, Red Mountain on the Kenai Peninsula near Seldovia contains a significant chromium deposit. Significant ore bodies may occur in the ultramafic bodies on Kodiak. Another belt of high mineral potential occurs along the west side of Lower Cook Inlet just outside the study area. Included here are large, low-grade titaniferous magnetite deposits as well as copper prospects. There has been considerable activity in this area over the past few years. A copper prospect was drilled west of Mt. Douglas in 1971 and an extensive exploration program for iron was carried out several years ago. There was no activity in 1972. Most of the study area is presently closed to mineral location (Figure 49). Much of the area is within federal reserves (national monuments or wildlife refuges), while the rest is tied up under the Alaska Native Claims Settlement Act of 1971. Mineral activity in the region will probably not increase until this complex land situation is resolved, which may take several years or longer. Nonmetallic There are few known occurrences of nonmetallic minerals in the study area (Figure 50). They include several coal deposits, several pumice deposits, and a sulphur deposit. Construction materials, including sand and gravel, have been identified at several locations by Q 59° »M»e + 58° > = LAND OPEN + 57° VY GA FEDERAL LAND OPEN a LC] CLOSED TO MINERAL LOCATION NOTE = Status of land subject Figure 49 Mineral location status of lands, + 56° ISION Gulf of Alaska region, 1972 (from Ak. Div. Geol. & Geophy. Surveys 1973). + 55° ° 8 EI 164° 162° 160° 158° 156° 59° y Figure 50. Occurrences of Nonmetallic Minerals, Western Guit of Alaska. 58° 57° 56° 55° 164° 162° 160° 158° 156° =~ ® aucusTINE 3 Known Coal Deposits (Barnes 1967) Sulphur Deposit (Eakins 1970) Possible Gravel Deposits (As identified by Resource Planning Team) Pumice Deposits (Moxham 1951) 57° 56° 55° 54° SEs 136 the Resource Planning Team of the Joint Federal-State Land Use Planning Commission. Many more such deposits undoubtedly occur along stream valleys and elsewhere, and they will be discovered and exploited as the need arises. Coal is present in significant quantities in three coal fields on the Alaska Peninsula--the Herendeen Bay, Unga Island and Chignik fields. These fields have been summarized by Barnes (1967). Bituminous coal occurs in the Late Cretaceous rocks that underlie at least 15 sq. km. of the Peninsula between Herendeen Bay and Port Moller (Herendeen Bay field). Most of the coal occurs in a large number of closely spaced beds ranging from a few cm. to several meters in thickness. Little is known about the extent or continuity of the beds, and no reliable estimate of reserves can be made. Tertiary lignite-bearing rocks also occur in the area, but they probably do not have much economic value. Some development work occurred between 1880 and 1902, but no commercial production took place. Since Herendeen Bay is blocked by ice much of the time, past development plans included transportation overland 24 km. to Balboa Bay. Lignite coal beds ranging from a few cm. to several meters in thickness underlie a 15 sq. km. area of northwestern Unga Island (Unga Island coal field). These coals appear to be of poor quality. One mine operated briefly in 1911, but only minor production resulted. Discontinuous bituminous coal beds up to severel meters thick occur in a belt of Late Cretaceous rocks along the northwest shore of Chignik Bay (Chignik coal field). Not enough data is availabe to estimate reserves. Sulphur deposits occur in and around the vents of several volcanoes on the Aleutian Islands-Alaska Peninsula. They have been prospected and drilled from time to time, depending on the market for sulpher. Serious preparations were made several years ago to mine one of the larger deposits at Makushin Volcano near Dutch Harbor, just south of the study area. The only significant deposit within the study area occurs near Stepovak Bay. The inaccessibility of this deposit--it occurs on a near- vertical slope covered with ice and snow--prevented close examination of the deposit by the State Division of Geological Survey (Eakins 1970). Float from the area suggests fairly low concentrations, and it is unlikely that this deposit will be of economic interest in the immediate future. Pumice deposits are the only other nonmetallic mineral in the study area that might have economic importance, mainly as concrete aggregate or admixtures. Potential deposits have been identified near Katmai and in the Veniaminof-Aniakchak area (Moxham 1951). Reworked pumice and ash deposits up to 5 meters thick, mainly from the Katmai eruption, occur 137 along many of the drainages southeast of Katmai, especially along the Katmai River and at the heads of Kukak, Kinak, and Amalik Bays. Minor production occurred at the latter site in 1950. The quantity and quality of these deposits suggest they would be suitable for commercial use. Other deposits are scattered in the drainages surrounding Veniaminof and Aniakchak Volcanoes, but none of these have been investigated or evaluated in any detail. Deposits also occur on Augustine Island in Lower Cook Inlet; they were mined for a brief period between 1946 and 1949. OIL AND GAS Introduction The oil and gas potential of the study area is essentially unknown, but it is believed by industry to be quite high. Exploration has been minimal and only a few test wells have been drilled onshore and none offshore except in Wide Bay. There currently is a high degree of interest and activity in the area by petroleum companies. Exploration is presently being hampered for several reasons. Onshore, most of the land on the east side of the Alaska Peninsula is not available for leasing. Part of this land lies within Katmai National Monument and the rest is unavailable pending settlement of the Alaska Native Claims Settlement Act of 1971. Offshore exploration depends entirely on lease sales by the state and federal governments. There presently are no plans by the state for any offshore lease sales in the area, although more state sales in Lower Cook Inlet are likely to be held in the near future. There are no federal Outer Continental Shelf (OCS) sales planned for the area either, but a sale for Lower Cook Inlet is tentatively scheduled for 1976-1977 (Figure 51). This latter sale depends on settlement of litigation between the state and federal governments over ownership of Lower Cook Inlet. An OCS sale in the Gulf of Alaska is planned, but no date has been scheduled yet. It is unlikely that the sale will take place until the environmental impact of petroleum exploration and development in the area is evaluated. To this end, the Council on Environmental Quality (CEQ) has undertaken a one year comprehensive study to assess this impact. They have been holding hearings throughout the country including a two day session in Anchorage on September 26-27, 1973. A final report is due April 1974. If held, a sale in the Gulf of Alaska probably would cover the eastern part--Hinchinbrook Entrance eastward to Yakutat Bay--since this is the area where most exploration has taken place and nominations already have been submitted by industry. 977 $ f Iv Tats fo ALASKA (LOWER COOK INLET) ALASKA (BERING SEA SHELF) r C= CALL FOR NOMINATION DES: DRAFT ENVIRONMENTAL STATEMENT FES= FINAL ENVIRONMENTAL STATEMENT ND= NOMINATIONS DUE T= ANNOUNCEMENT OF TRACTS PH® PUBLIC HEARING N2 NOTICE OF SALE A decision whether to hold any of the lease sales listed will not be made until completion of all necessary studies of the environmental impact and the holdings of public hearings; as a result of the environmental, technical and economic studies employed in the decision-making process,’a decision may, in fact, be made not to hold any sale on this schedule. If CEQ's study of the environmental impact of oil and gas production on the Atlantic Outer Contin- ental Shelf and in the Gulf of Alaska, determines that development in these areas can proceed in an en- vironmentally satisfactory manner, lease sales in, one or both areas will be added to the proposed sched- ule at the carliecst practicable time. The holding of sale 43 is contingent upon the outcome of pending litigation with Alaska regarding jurisdiction over this area. Figure 5!. Proposed schedule by the Bureau of Land Management for provisional OCS leasing (from Federal Register, V. 38, No. 132, Wed, July 11, 1973), 8cT 139 The oil and gas resources of the study area are best discussed under the heading of three separate provinces: the Alaska Peninsula Mesozoic Province, the Shumagin-Shelikof Tertiary Province, and the Kodiak Tertiary Province (Figure 52). Following discussion of these provinces, there is a summary of present oil company activities and interests in the area. Data for the following sections were taken from discussion with oil company representatives plus various literature sources, especially Miller et al. (1959), Gates et al. (1968), and von Huene et al. (1971). Alaska Peninsula Mesozoic Province Mesozoic marine sedimentary rocks of Permian through Cretaceous age outcrop along the entire length of the Alaska Peninsula (Figure 52 and units 1, 3 and 4 of Figure 31). These rocks probably extend offshore to form a belt about 80 to 100 km. wide. This belt may extend west across the southern end of the Peninsula and out under the Bering Sea continental margin. All of these rocks contain oil and gas shows or seeps on the surface and shows of oil and gas in test wells; they all have definite petroleum potential. Permian through Lower Jurassic rocks probably occur throughout the area in the subsurface, but they only outcrop in one place on the Peninsula south of the Bruin Bay fault at Puale Bay. This section contains abundant limestones and some sandstones that are potential reservoir rocks, and dark shales that could be potential source rocks. Petroliferous beds and tar sands have been reported from these beds (Miller et al. 1959). All of these rocks are essentially untested in the subsurface. A thick section (over 6,000 m.) of predominately marine clastics of Middle Jurassic through Lower Cretaceous age form the rest of the Mesozoic section exposed on the Alaska Peninsula. This section contains abundant sandstones and conglomerates (potential reservoir rocks) intertongued with marine shales (some known to be potential source rocks). These rocks are also petroliferous as evidenced by numerous oil and gas seeps and petroliferous beds, mainly in the Kanatak area (Figure 52). These oil and gas seeps were first discovered in the late 1800s. Later investigations reported a flow of about one-half barrel-per-day from the largest seep in the Kanatak area that had covered several acres with a petroleum residue (Capps 1922). This area was visited during the summer of 1973 by geologists of the U.S. Bureau of Mines as part of an overall research project to evaluate oil seeps in Alaska. Water, oil, asphalt, and gas samples were taken at seeps and along streams draining the seep areas. Preliminary results suggest that surface waters contain high amounts of petroleum, but it is not known yet how much is reaching the sea.! At one seep, samples of asphalt about 15 to 20 cm. thick lnon Blasko, Petroleum Engineer, U.S. Bureau of Mines, Anchorage, Personal communication. 164° 162° 160° 158° 156° 154° 152° 150° T Figure 52. Oil and gas provinces and resources, Western Gulf of Alaska (see Table 14 for list of wells). 59° Area of known oil & gas seeps 87° O- drilling o- dry - abandoned 55° ¥- show of oil-gas ° 164 162° 160° 158° 156° 154° 152° 150° OF 141 covered approximately 5 acres, possibly the same seep reported earlier by Capps (1922). It also was observed that vegetation was greener and appeared to grow better around seeps. These studies by the Bureau hopefully will continue in 1974, when other localities along the Alaska Peninsula will be visited. At least 12 shallow test wells were drilled on two broad anticlines in the vicinity of the seeps between 1903 and 1940 (Figure 52 and Table 14). Almost all of these contained shows of oil and gas, mainly in the Upper Jurassic rocks. Seven additional deep tests were drilled by major operators between 1959 and 1967, but only minor shows of gas were reported from two of these wells. The lack of commercial production appears to be due to the lack of adequate reservoir rocks, which seems to be common in many Mesozoic rocks. Reservoir qualities might improve to the southwest, where Mesozoic rocks occur in the subsurface. Mesozoic rocks also extend offshore in the subsurface under Lower Cook Inlet; and they undoubtedly will be an important objective if any lease sales occur here. There has been no estimate of reserves for this particular province, but the U.S. Geological Survey (1972) has estimated 1.5 billion barrels for the entire Alaska Peninsula. Future success depends on finding favorable structural-stratigraphic situations. Shumagin-Shelikof Tertiary Province Several thick Tertiary basins may occur offshore along the shelf between the Shumagin Islands and Shelikof Strait. This is suggested by onshore Tertiary deposits and large offshore gravity lows (Barnes 1967) (Figures 31, 35, 36 and 52). No data on the size or thickness of these basins is available, but they probably contain good reservoir rocks and may contain marine source beds. These source beds, if present, may or may not have been buried deep enough to generate petroleum. The two basins southwest of Kodiak Island overlie the belt of highly deformed and partly metamorphosed flysch deposits that extends from the Kenai Peninsula to the Shumagin Islands. This lessens the opportunity for the underlying rocks to supply oil to the overlying Tertiary rocks, since any oil generated would have been expelled during the earlier cycle of deformation and uplift. The oil potential of the basin in Shelikof Strait is enhanced, however, since it overlies the offshore extensions of the Mesozoic province discussed above. Oil found in the continental Tertiary beds in the Cook Inlet Basin possibly originated from similar Mesozoic rocks. The Shelikof Strait basin offers the most attractive prospect of any of these basins. Table 14. Wildcat wells, Alaska Peninsula Mesozoic Province (see Figure 52 for location of wells). 142 Completion Total Depth No. Name Date (in meters) Status 1. Amoco, Cathedral R. No. 1 Drilling 2. Pan Amer., David R. No. 1 and la 8/18/69 4,197 Dry & Abd. 3s Pure, Canoe Bay No. 1 10/26/61 2,024 Dry & Abd. 4. Pan Amer., USA Hoodoo L. No. 1 1/13/70 2,454 Dry & Abd. 5. Pan Amer., USA Hoodoo L. No. 2 4/28/70 3,810 Dry & Abd. 6. Cities Service, Painter Ck. No. 1 7/16/67 2,412 Dry & Abd. 7. Richfield, Wide Bay No. 1 10/17/63 3,830 Dry & Abd. 8. Humble, Bear Creek No. 1 3/04/59 4, 382 Dry & Abd. 9 (Approximately 12 shallow test Dry & Abd. wells were drilled between 1904 and 1940) Note: More detailed information about these wells is available from the Alaska Division of Oil and Gas, Anchorage. All of these basins are virtually unexplored, and apparently very few seismic lines have been run in the area. They certainly offer attractive secondary prospects for future exploration programs. Another area of Tertiary rocks with some oil potential occurs along the shelf from the Shumagin Islands south. Tertiary rocks occur on most of the islands, but their thickness and extent offshore are unknown. They contain marine rocks and also coal-bearing rocks that might provide sources for oil and gas. They also may overlie Mesozoic rocks that could be a source of oil as mentioned above. The presence of abundant volcanic rocks and volcanic fragments in these sediments, however, makes them more susceptible to alteration, which tends to reduce significantly the reservoir quality of the sands. This makes the area somewhat less attractive. Kodiak Tertiary Province A brief description of the Kodiak Tertiary Province has been presented earlier. The petroleum possibilities of this province cannot yet be evaluated. No test wells have been drilled and no indications of petroleum have been reported from the outcrop areas exposed along the southeast coast of Kodiak, although some of these rocks have good reservoir qualities. Occurrences of oil and gas do occur in similar rocks in a comparable province in the eastern Gulf of Alaska region (Plafker 1971). The Kodiak Tertiary province basically consists of a thick sequence of deformed Early to Middle Tertiary sedimentary rocks, extending from Kodiak Island out to the shelf edge and beyond. Superimposed on these rocks is a relatively undeformed Late Tertiary basin (Figure 34). The rocks adjacent to Kodiak have been highly folded and faulted (fault zone on Figure 34). The relatively undeformed, Late Tertiary sediments filling the basin contain some anticlinal structures and offer favorable objectives. Especially attractive is the shelf edge arch which is characterized by large anticlinal structures and numerous truncations and unconformities that could provide stratigraphic traps. Underlying this entire area is a thick wedge of marine rocks probably containing source rocks that have been buried deep enough to generate petroleum. The main unanswered question about the province is the orgin of the thick wedge of sediments beneath the shelf edge (Figure 34) and the availability of adequate reservoir rocks in these rocks. A single series of dredged samples from the shelf edge arch area produced deep- water siltstones of Miocene to Pliocene age. The origin of the thick wedge could be due to either folding and repeated thrusting up of fine- grained, deep ocean sediments or uplift of a former trench or continental rise. The latter origin may have provided adequate reservoir sands deposited by turbidity currents. 143 144 Portions of the province lie in fairly deep water beyond the shelf edge. This includes a large area where extraction of petroleum is not yet technologically feasible, although it may be in the near future. This western portion of the Gulf of Alaska has received relatively little exploration effort compared to the eastern portion or the Lower Cook Inlet, but it is considered a highly attractive target for future exploration. Petroleum reserves for the entire Gulf of Alaska have recently been estimated as high as 60 billion barrels. ! Oil Company Activities and Interests Oil company activity and interest in the general Gulf of Alaska area is extremely high. Table 15 gives some idea about past exploration activity in the overall area through 1972. During 1973 several seismic crew months were spent in Lower Cook Inlet, one crew month was spent offshore Unimak Island-Dutch Harbor, and approximately one crew month was spent onshore near Pavlof Bay. In addition, approximately eight crew months were spent by geologic field parties on the Alaska Peninsula, although part of this effort possibly was directed toward the Bristol Bay Tertiary Province on the north side of the Peninsula. Approximately 12 shallow test wells were drilled near oil seeps between 1903 and 1940, and almost all contained shows of oil and gas. Seven deep exploratory tests were drilled on the Peninsula between 1959 and 1967 to test the Mesozoic rocks, but only minor shows of gas were encountered in several wells. There is presently (April 1974) one exploratory well drilling on the Southern Alaska Peninsula north of Cold Bay (Amoco Cathedral River Unit 1). This well apparently is a deep test of Mesozoic rocks on the Southern Alaska Peninsula. In addition to the geological and geophysical activity mentioned above, an extensive shallow core hole program was carried out by Exploration Services Company in the Gulf of Alaska and Lower Cook Inlet during 1971 and 1973 in order to obtain stratigraphic information. Over 100 holes were attempted to depths up to 180 m. during eight ship crew months of operation. Equipment difficulties hampered much of the operation, but much useful information was obtained. None of the holes was drilled in the Western Gulf of Alaska. Supplemental to this was a limited soil boring program to obtain strength of materials data needed for pipeline and platform construction. Three stratigraphic tests are also planned to be drilled offshore the Gulf of Alaska in 1974 by Exploration Services Company. Of the five possible drilling sites, three are in the eastern Gulf of Alaska and two are within the study area off Tugidak Island and in Shelikof Strait. These latter two sites probably would be testing the Tertiary basins off Kodiak mentioned earlier. These tests would be approximately 3,000 m. off-structure stratigraphic tests that would be shut down if any lrestimony of John Silcox, Standard Oil Co., CEQ Hearings, Anchorage, September 26, 1973. Table 15. Summaries of exploration activities, Gulf of Alaska - Alaska Peninsula. A roundup of geophysical work in Alaskan waters No. partici- Year Operator pants Mileage Type Contractor Gross cost Remarks GULF OF ALASKA 1985 16 14,000 Aeromagnetic Aero Eastern sector 1965 9 30,000 Aeromagentic Aero Western sector 1965 Texaco 15 228 ~~ Reflection GSI $ 246,020 Recon. 1966 Texaco 25 753 Reflection GSI 1,050,000 Eastern sector 1966 Texaco 23 331 Reflection GSI 1,035,000 Western sector 1966 SC* 1,600 Reflection GSI 1967 Conoco 30 4,698 Reflection Olympic 2,682,150 | USGS purchased 1967 Conoco 31 708 Reflection Olympic 307,316 USGS purchased 1967 SC 5,000 —— Reflection GSI 1968 3 3,900 Aeromagnetic Aero Southeast sector 1963 Socal 31 4,300 Aeromagnetic GSI! 2,811,000 USGS purchased 1968 Union 22 7,116 — Gravity GSI 356,000 1968 SC 1,500 ‘Reflection Olympic 1968 SC 2,000 Reflection Western 1S68 SC 7,000 Gravity GSI 1969 SC 5,500 Reflection GSI 1969 SC 2,000 Reflection Olympic 1969 SC 2,000 ‘Reflection Western 1970 SC 2,500 Reflection GsI 1970 sc 750 — Reflection Western 1971 SC 2,000 Reflection GSI 1971 SC 2,000 Reflection Western COOK INLET AND SHELIKOF STRAIT 1962 13 9,200 Aeromagnetic Aero Cook Inlet 1964 12 4,000 Aeromagnetic Aero Lower Cook Inlet 1964 10 2,000 Aeromagnetic Aero Lower Cook Inlet 1965 Texaco 231,150 Reflection GSI 893,000 Lower Cook Inlet (from Oil and Gas Journal, February 28, 1972) B. Geophysical and surface mapping activity, crew months (excluding U.S.G.S. and State work). Alaska Peninsula- Bristol Bay Gulf of Alaska Surface Surface Year Geology Geophysical Geology Geophysical 1970 6 4 12 4 1971 3 3 1l 7 1972 9 3 8 1l (from A.A.P.G. Bulletins, V.55, p.947; V.56, p.1184; V.57, p-.1416) 145 146 significant oil and gas shows were encountered. Participants will decide on the final three sites. Exploration Services also has applied to the federal government for permits to drill two similar tests in OCS waters in the Gulf of Alaska. As noted above most of the activity has been centered around the eastern Gulf of Alaska and Lower Cook Inlet. The eastern Gulf of Alaska was nominated by industry for a potential lease sale in 1968, and consequently, most exploration work has concentrated on this area. This sale was cancelled, and a future sale in this area has not been ‘officially scheduled (Figure 51). The possibility of both federal and state lease sales in Lower Cook Inlet also has generated interest, and consequently, the offshore Western Gulf of Alaska has been temporarily deemphasized as an exploration objective in the near future. This explains the relative lack of information compiled by the industry. In fact, the Western Gulf probably would rank fourth in priority behind the Eastern Gulf of Alaska, Lower Cook Inlet, and the Alaska Peninsula. This is not because of its oil potential but because of the lack of projected lease sales and the lack of detailed offshore geological and geophysical data. Further detailed work in this area probably will not be done until such lease sales are proposed. In addition to geological and geophysical data about the Gulf of Alaska, petroleum companies have been gathering together environmental data. This includes a general description of the physical and biological environment plus studies on the impact of oil operations on the environment. These studies are being coordinated through a consortium of 21 oil companies known as the Gulf of Alaska Operators Committee (Table 16). This committee presented a lengthy testimony at the Anchorage CEQ hearings Septemeber 26, 1973. They orally summarized their environmental studies and also submitted extensive written testimony and documents that detailed their studies. Although this testimony was primarily directed toward development in the Eastern Gulf of Alaska, much of the data are generally applicable to the entire Gulf area. The Committee has additional environmental data that are directly applicable to the Western Gulf of Alaska but not presently summarized in any usable form. The committee has expressed willingness to cooperate in making this data available. OTHER ENERGY RESOURCES Geothermal The Alaska Peninsula has a high potential for geothermal resources. All of the recent or active volcanic centers contain potential geothermal systems that could be exploited as an energy source. None of the volcanic Table 16. Participating compaines in Gulf of Alaska Operators Committee as of July 1973. Amoco Arco Ashland BP Cities Conoco Exxon Gulf Marathon Mobil Monsanto Murphy Pennzoil Phillips Placid Shell Skelly SOCAL Sun Texaco Union 147 148 centers in the study area has yet been officially classified as a "Known Geothermal Resource Area" (KGRA), which requires a competitive lease sale prior to exploration (Godwin et al. 1971). Most of these areas have been designated, however, as areas valuable prospectively by the U.S. Geological Survey (Godwin et al. 1971) or as areas of potential geothermal energy by the Resource Planning Team of the Joint Federal- State Land Use Planning Commission. The areas outlined by the Team are shown on Figure 53. Thermal or hot springs also generally are the surface manifestation of geothermal systems. At least 13 such springs, all associated with volcanic rocks, have been reported on the Peninsula (Biggar 1972; Miller 1973) (Figure 53). Undoubtedly many more exist. Only a few have any temperature or chemical data available for them. A research program by the U.S. Geological Survey has been initiated recently to study Alaska geothermal areas including the recent volcanic areas of the Alaska Peninsula.! Three and one-half weeks of reconnaissance field work was conducted on the Peninsula in the summer of 1973 to study the geology of and to collect samples of recent and active volcanoes and hot springs. It is thought that the chemistry, age, and volumes of ejected and extruded material can be used to establish where a volcano is in its life cycle. This information can then be used to evaluate its potential as a geothermal energy source. In addition, the chemistry of the thermal springs and adjacent deposits can be used to tell the temperature of waters at depth. These reconnaissance studies hopefully will be used to pick areas for further detailed work including geophysics and possibly even drilling. No estimate of potential energy available from geothermal systems on the Peninsula is possible at this time, but it is undoubtedly large. Hydroelectric? There have been no significant hydro developments in the study area. Several very small projects were built to power saw mills and canneries prior to the age of the diesel engine, but most of these are now abandoned. The physical potential includes numerous sites ranging from very small up to around 30,000 kilowatts in size. Inventory grade analyses indicate the most promising are the Terror Lake, Uganik, Karluk, and Frazier Lake Projects (Figure 54 and Table 17). In comparison with -other hydro potentials in Alaska, the four projects are considered relatively small and relatively costly. lrom Miller, Geologist, U.S. Geological Survey, Anchorage, Personal communication. 2R.J. Cross, Chief of Project Development Division, Alaska Power Administration, Juneau, Alaska, Personal communication. 59° 58° 57° 56° 164° 162° 160° 158° 156° 154° 152° 150° Figure 53. Gulf of Alaska (from Miller 1973 and unpublished data- from Resource Planning Team of Joint Federal-State Land Use Planning Commission). Geothermal areas and thermal springs, Western A_ Active Volcanic Centers 55° EL area with potential geothermal energy Seo 200 <7 i _ (~T _Thermal spring 7 @ “ oy 7 i a oe 6000 ee — : p< | 7 4 164 162° 160° 158° 156° 154° 152° 150° e+ 150 Karem KODIAK ISLAND 57° 154° Figure 54. Most favorable hydro potentials, Kodiak Island (from files of Alaska Power Administration, Juneau, Personal communication). Table 17. Hydro Potential Sites, Kodiak Island (from Alaska Power Administration, Juneau, Alaska, Personal Capacity 1000 KW Terror Lake Utility Definite Project Report 30,000 (ultimate) Inventory Plan 15,000 Uganik 15,000 Karluk 34,000 Frazier Lake 7,500 communication). Annual Energy Million KWH 130 64 68 149 33 151 152 The Terror Lake Project has received extensive investigation and is considered the most attractive hydro site on the Island. Detailed project studies by consultants to the Kodiak Electric Association (KEA) were completed in 1967, but the project was not developed because of high costs. KEA has recently reopened its consideration of Terror Lake as one of the few potentially feasible alternatives to diesel-fired generation for the Kodiak area. Available studies do not indicate any significant hydro potentials on the Alaska Peninsula portion of the study area. In comparison with diesel engines, investment costs for the identified hydro projects are very large. Cost factors and relatively small power requirements have precluded hydro development in recent years. Development of the Terror Lake Project is a near future possibility, but it appears unlikely that other potential hydro projects of the study area will be developed in the foreseeable future. More specific data on Terror Lake is available from the Kodiak Electric Association and for the other projects from the Alaska Power Administration, Juneau, Alaska. Wind Power! The wind power potential of Alaska is very large and represents a yet untapped energy resource that could be "packaged" and exported or used locally. Power generated from windmills is especially attractive as a low-cost energy source well suited for residences, villages, or other small onshore facilities. Use of such power would be dependent on developing adequate capacity for storing the energy during periods of low wind. The University of Alaska's Geophysical Institute is currently making an assessment of the wind power potential of Alaska. This assessment includes conducting wind surveys at various locations to characterize the wind regimes (Wentink, In Press). The Western Gulf of Alaska area offers an excellent laboratory for these studies, since the wind blows hard in this region a large percentage of the time. Several sites within the area are being investigated as part of this project, and one location, Cold Bay, is being considered as a prime candidate for further large-scale wind power investigations. Wind data for Cold Bay and also Cape Sarichef on the west end of Unimak Island is presented in Table 18. ly, Wentink, Geophysical Institute, University of Alaska, Fairbanks, Personal communication. 153 Table 18. Wind Velocity data from selected stations, Western Gulf of Alaska (from Wentink, In Press). Mean Annual Velocity Percent of Time Percent of Time Location (in knots) at 7-21 Knots above 21 Knots Cape Sarichef 13.7 (1952-56?) 57.5 18.5 Cold Bay 15.1 (1956-60) 64.0 24.0 154 VOLCANISM Most of Alaska's recent and active volcanoes! occur along an arcuate belt extending over 1600 km. from Mt. Spurr opposite Anchorage to the tip of the Aleutian Islands (Figure 55). This belt is part of a larger chain of volcanoes that rim the entire Pacific Ocean Basin, the so- called "Ring of Fire." This "Ring" represents a narrow zone characterized by active tectonism and seismicity as well as volcanic activity landward of a deep-sea trench (Figure 56). The recently developed theory of plate tectonics suggests that all of these factors are related to the underthrusting of one crustal plate beneath another along a subduction zone or "Benioff" zone (Figure 39). Lavas erupted by Pacific Rim volcanoes, therefore, probably are generated by the partial melting of oceanic crust and upper mantle rocks as they are thrust under the adjacent plate. The arcuate volcanic belt of Alaska contains at least 60 centers that have erupted in recent time (the last 10,000 years). Actvity has been recorded at about 40 of these volcanoes since 1700 A.D., and there has been some type of activity almost every year somewhere along the belt. The latest eruption was on Great Sitkin Volcano in February 1974. Coats (1950) and Powers (1958) presented good overall summaries of Alaska's past volcanic activity. Sixteen of the active centers occur within the study area, ranging from Pogromni Volcano on Unimak Island to Katmai and associated centers toward the northern end of the Peninsula. The location and a summary of each of these volcanoes is presented in Figure 57 and Table 19 res- pectively. In addition there are many other centers that undoubtedly have been active in fairly recent times (within the past few thousand years) (Figure 57 and Table 19). Any of these centers could erupt at any time. The volcanoes form most of the high peaks of the Alaska Peninsula, ranging from a low of about 825 m. at Novarupta Volcano to over 2800 m. at Shishaldin Volcano. In addition to the spectacular scenery offered by these volcanoes, they also represent some of the best examples of recent volcanic features, (cones, craters, calderas, etc.) found anywhere in the world. The area surrounding the Katmai group already has been set aside as a national monument, and several others (Pavlof, Veniaminof, Shishaldin, and Aniakchak) are being considered for some type of recognition in the national system. leecent volcanoes are those that probably have erupted during the past 10,000 years but have no historic record of activity. Active volcanoes are those that have had reported activity in historic time (since 1700 A.D.). REDOUBT- ILIAMNA AUGUSTINE. KISKA LITTLE SITKIN CERBERUS GARELO! TANAGA fa 6 % ° a KANAGA |GREAT SITKIN CHI PAVLOF SISTER PAVLOF. MAKUSHIN BOGOSLOF OKMOK KAGAMIL CARLISLE SEGUAM Y AKUTAN VSEVIDOF CLEVELAND YUNASKA AMUTKA SARI CHEF KOROVIN | NOVARUPTA PEULIK IGINAGAK_, TRIDENT. ROUNDTOP ISANOTSKI SHISHALDIN FISHER POGRAMNI SPURR, ™ ———! A Py KATMAI MAGEIK MARTIN a WRANGELL~ KONIUu! Figure 55. Active volcanoes in Alaska. | 150° SSI 156 : 2 Sr ee ees a Re > ce <4 < SS ad , KR » eS S Qe, SAN FRANCISCO; 4 KK Ss PPPOOR}RNR. Ye ATLANTIC ‘ So Me _— OCEAN SS , BANCKOE $j qj > Ss v ENS ue S SS Ge PACIFIC OCEAN yay “ me. aa INDIAN OCEAN ye 2, Wy S$ HG Figure 56. Map showing Pacific Rim belt of active tectonism, and seismicity, and volcanoes, the "Ring of Fire." (from Hansen and Eckel 1971). 150° 158° 156° 164° 162° 160° 59° Figure 57. Location of Recent and active volcanoes, Western Gulf of Alaska. See Table 19 for more details : N about volcanoes (from Powers ) , Q - - 58° 1958). 57° 57° 56° 56° 55° 55° A | RECENT canned A ACTIVE VOLCANOE 54° — — _ a 54° 154° 152° 150° a N 160° 158° 156° Table 19. Summary of recent and active volcanoes, ! Alaska Peninsula (Adapted from Powers 1958, MacDonald 1972, Forbes, In Press) Remarks on Activity Approx. Date of summit ht. No. of eruptions last No.2 Name (meters) since 1700 A.D. eruption 1. Pogromni 2,002 4 1830 2. Westdahl 1,560 1 1964 3. Fisher 1,094 1 1826 4. Shishaldin 2,857 23 1967 5. Isanotski 2,446 4 1845 1. Ash eruptions-1795, 1820, 1827-30; lava flow-1796. Ash and lava, March 10-April 16, 1964. Possible ash eruption. Active-1775-78; smoke-1790, 1865, 1880-81, 1897; ash eruptions-1824-26, 1827-30, 1838, 1842, 1883, 1898, 1922, 1925, 1928-29, 1946-53, 1955, 1963, 1967. Explosive clouds of ash followed by intense steam emission, no lava reported-January 28, 1967. Ash eruptions-1795, 1830, 1845; possibly some are Roundtop eruptions. Recent volcanoes are defined as those that probably have erupted during the past 10,000 years, but have no historic record of activity. They could erupt at any time. Active volcanoes are defined as those that have had reported activity in historic time (since 1700 A.D.). Location of volcanoes are shown by number on Figure 57. 8ST Table 19, Continued. 6. 10. ll. 12. 13. 14. 15. 16. 17. 18. Roundtop Amak Frosty Emmons Hague Double Crater Pavlof Pavlof Sister Dana Veniaminof Purple Aniakchak Chiginagak 1,871 488 2,012 1,326 1,341 1,465 2,518 2,142 1,280 2,575 954 1,355 2,073 1? 25 1835? 1973 1786 1944 1931 1929 Ash eruption-1825; possibly some eruptions reported for Isanotski should be credited to Roundtop. Probably no historic activity. Probably no historic activity. Probably no historic activity. Probably no historic activity except intermittent steaming. Probably no historic activity. Active-1970, 1880, 1892; smoke-1838, 1852; ash eruptions-1846, 1866, 1901, 1916, 1922-24, 1929-31, 1926-45, 1948, 1950-53, 1963; ash and lava-1966; eruption of cloud of ash and smoke over €,000 m. high on November 13, 1973. Active 1762-1786. Probably no historic activity. Smoking-1830-38, 1852, 1874; active-1944; ash eruptions-1838, 1892, 1939; lava eruption-1930. Probably no historic activity. Steaming, ash and lava eruption-1931. Smoke and intermittent steaming-1852. 6ST Table 19, Continued. 19. Peulik 20. Martin 21. Mageik 22. Novarupta 23. Knife Peak 24. Trident 25. Katmai 26. Denison 1,474 1,844 2,210 825 2,316 1,832 2,047 2,256 1852 1960 1946 1912 1968 1931 Ash eruption-1814, Smoke-1852. Steaming intermittently since 1912; ash eruption ? -1912. Ash eruptions-1912, 1927, 1936, 1953; Active-1929, 1946. Vent breached during 1912 Katmai eruption; pyroclastics erupted first followed by extrusion of plug dome. Vent believed to be one of main sources for ash and pumice flow deposits (glowing avalanche) in Valley of 10,000 Smokes. No historic activity, but has 2 sulfurous fumaroles on summit and flank. Steaming-1912; lava eruption-1953; explosive, ash charged vapor columns to great heights-April, 1963 and May, 1964; vent clearing explosions plus ash eruptions-December, 1967 to February, 1968, November, 1968. Explosive eruption with vast pumice and ash deposits accompanied by caldera collapse-1912; steam-1931. Probably no historic activity. O9T Table 19, Continued. 27. Steller 28. Kukak 29. Kaguyak 30. Fourpeaked 31. Douglas 2,256 2,012 855 2,104 2,134 Probably no historic Probably no historic Probably no historic Probably no historic Probably no historic activity. activity. activity. activity. activity, except for intermittent steaming. T9T 162 Pacific Rim volcanoes generally are called andesitic, which reflects the chemical composition of the magmas. Andesitic magmas contain more silica and are more viscous than normal oceanic basalts such as those on Hawaii. Eruption of these types of magmas is much more violent and explosive in nature. Material ejected in a fragmental condition (pyroclastic material--ash, lapilli, or bombs) usually builds up large composite cones. Other volcanic phenomena associated with these eruptions include lava flows, ash flows, volcanic landslides and mudflows, ash falls, and gases. Finer material ejected into the air is carried downwind at various distances depending on the frothiness or fineness of the material and the direction and intensity of the wind. Generally, only minor amounts of lava are erupted as flows. Eruptions can be extremely violent, but moderate eruptions are more representative of these volcanoes (Wilcox 1959). The famous Katmai eruption of 1912 is an excellent example of a violent eruption; it ranks as one of the greatest eruptions in recorded history. More than 25 cu. km. of ash and pumice were blown into the air or flowed into the Valley of Ten Thousand Smokes, and up to a foot of ash fell on Kodiak 160 km. away (Figure 41). An up-to-date summary of this eruption and other volcanic activity in the Katmai region is contained in a book soon to be published by the University of Washington Press (Forbes, In Press). Augustine Island, located just north of the study area in Lower Cook Inlet, also erupted violently in 1883 and presently is building lava domes in its summit crater that could cause another violent explosion in the near future. This volcano is under intense study by the Geophysical Institute, University of Alaska, Fairbanks. The eruptions of Trident Volcano in 1952, Mt. Spurr opposite Anchorage in 1953, and Redoubt in 1966-1968 are examples of the less intense type of eruption more characteristic of these volcanoes (Wilcox 1959). They consisted of bursts of gas and ash that rose vertically as a cloud to altitudes up to 20,000 m. These bursts were accompanied by small, viscous, blockylava flows at the vent area. Mudflows composed of ash and meltwater that flowed down the flank of the mountains were mistaken for lava flows. The past and potential effects of volcanism in the area are discussed in a later section of this report (IX). SEISMICITY Alaska is one of the most seismically active areas of the world, both in numbers of earthquakes and in the energy they release. Most of the Alaska earthquakes occur along an arcuate belt extending from the western end of the Aleutian Islands to Prince William Sound (Figure 58). This Alaska belt is part of a narrow, almost continuous earthquake zone that rims the entire Pacific (Figures 56 and 59). This zone, characterized also by active volcanism and tectonic deformation, define the margins of the large Pacific Plate (Figure 39). According to recent 16S 45 SIBERIA Figure 58. 1961-1967 EPICENTERS ESSA-CGS ® 0-50 KM a »SOKM Seismicity of Aleutian Arc-southern Alaska, 1961-1967 (from Kienle 1971). 45 cot Figure 59. Seismicity of the earth, 1961-1967 (from Sykes 1972). vot 165 theories of plate tectonics, the Pacific Plate is being thrust under the North American Plate along the Aleutian Trench, thus providing a generating mechanism for the seismicity (Figure 39). Most of the earthquakes in the area originate at shallow depths (0- 70 km.). The depth of their occurrence corresponds roughly to their distance from the trench, and the distribution of hypocenters approximately defines the configuration of the downgoing plate (Lahr et al. 1974). The lack of many deeper earthquakes may reflect the relatively young age of the underthrusting. About seven percent of the earthquake energy that is released annually on the earth originates in the Alaska seismic zone (Hansen and Eckel 1971). A large percentage of this energy release occurs during large earthquakes. Between 1899 and May of 1965, nine Alaska earthquakes have equalled or exceeded Richter magnitude 8 and more than 60 have equalled or exceeded magnitude 7. The large earthquakes appear to correspond with the slippage of large blocks, which are defined by the distribution of aftershocks (Sykes 1972). Aftershock zones of all the very large earthquakes in the Alaska-Aleutian area from 1930 to 1970 have been plotted from data of Sykes (1972) (Figure 60). This plot suggests a regular space-time pattern for the earthquakes and also identifies major gaps in activity for large earthquakes. These gaps are regarded as likely sites for future large earthquakes (Sykes 1972). Significantly, the only large earthquake in Alaska during 1972 occurred in one of these seismic gaps (Sitka earthquake, July 1972, magnitude 7.2). The lack of a large destructive tsunami following the Sitka earthquake supports the theory of strike-slip movement along this portion of the plate boundary rather than underthrusting. An underthrusting movement is usually accompanied by large-scale displacements of the sea floor which often cause tsunamis. It also can be seen from the plot that the area of the great 1964 earthquake was without a large earthquake prior to 1964. Kelleher (1970) also noted that the area involved in the 1938 earthquake near the Shumagin Islands is now very quiet for large earthquakes. This seismic gap (the Kodiak-Shumagin seismic gap) shows especially well on the epicenter distribution map (Figure 58). From an analysis of space-time sequences, Kelleher predicted that a large earthquake will occur in the area sometime between 1974 and 1980. If it were to occur, it most likely would produce a large-scale displacement of the sea floor and possibly generate a tsunami, as did the 1964 earthquake. This Kodiak-Shumagin seismic gap mentioned above is centered directly in the Western Gulf of Alaska region, and is now the focal point of a joint research effort that hopefully will lead to the prediction of any large earthquake in the region. The project is being conducted by Lamont Observatory with support from the U.S. Geological Survey and the University of Alaska. During 1973, a detailed seismic net of 11 stations was established in the Shumagin Islands, and 5 more 1980 1960 1940 60°N —To -—_—_85.y—4-4 1 Hn 8.2 i---n SL. 4 IT0°E 1e0° 170°w 160°w 150°wW 140°w 130°wW Figure 60. Aftershock areas of great Alaska earthquakes (magnitude greater than 7.9) since 1930. These areas tend to abut without significant overlap and probably represent rupture along major crustal blocks. Gaps in activity are regarded as sites for future very large earthquakes. The apparent space-time relationship of the areas may provide a tool for earthquake predictions (from Sykes 1972). 99T 167 stations are planned for 1974 (Figure 61). In addition, there are several other stations in the area run by the University of Alaska, NOAA, and the U.S. Geological Survey, which also will be used to monitor seismic activity in the area and to supplement the project (Figure 61). The objective of this project is to delineate in detail the spatial distribution of low-level seismicity in the seismic gap and to obtain qualitative measure of any change in seismic activity and changes in the physical properties of the rocks that might occur prior to any large event. This type of detailed seismic information may or may not provide a direct means of predicting a large earthquake, but it certainly is a prerequisite for any future seismic prediction program. The susceptibility of the region to earthquakes and earthquake damage was made particularly evident during the great 1964 Alaska earthquake. With a magnitude of 8.3 to 8.7 this was one of the largest and most violent earthquakes to occur in North America during this century. Subsequently, the 1964 earthquake has received extensive \ study, and much has been written about it. Perhaps the most comprehensive account is found in a series of eight separate volumes published by the National Academy of Sciences, covering the following topics: Geology, Seismology and Geodesy, Hydrology, Biology, Oceanography and Coastal Engineering, Engineering, Human Ecology, and Summary and Conclusions. A brief discussion of the effects of this earthquake plus earthquakes in general is contained in section IX of this report. COASTAL PROCESSES AND EROSION Coastal erosion is generally defined as the wearing away of a shoreline and adjacent uplands by natural marine processes. In erosive action, more material leaves the system than enters it. The extent and degree of erosive action is a direct function of the geologic composition of the shoreline material and the sequence and magnitude of the processes. The main processes operating against the coastline in the study area are wind-generated waves and currents, which can get quite extreme during large storms. In a few hours, one large storm May Move more material than normally would be transferred in many years. Another condition unique to parts of the area is the extreme tidal variations, which permit a higher range of wave action to attack the coast. This forms a higher erosional scarp, which more readily induces bluff failure. Still another significant factor affecting coastal erosion in the study area is tectonic deformation. Tectonic deformation, particularly subsidence, can subject previously unaffected shorelines to accelerated coastal erosion. As mentioned in earlier sections, most of the coast of the Western Gulf of Alaska is rugged, steep, and rocky with narrow beaches. Here 59° 58°. 57° 56° 55° 164° 162° 160° Figure 61. Location of current and proposed seismic stations, Western Gulf of Alaska (from Geophysical Institute, Univ. of AK., Fairbanks, Personal communications). 158° 156° 154° 152° 150° 59° 58° 57° se° } ‘ ——— {ft 55° +7 | | | » A LAMONT GEOL. 0Bs! LX __LAMONT GEOL. BS. (PROPOSED 1974) | @Q NOAA. | | | | @ luses. + + ~ : 54° Tf Jus..s.—UNIv. oF Ak. | / @[unv. oF Ak. | ' © Jun. OF AK. ( PROROSED 19744) 158° 156° 154° 152° 150° gs! 169 coastal erosion probably is relatively slow because of the resistant nature of much of the bedrock cliffs, although in some areas of softer Tertiary sediments, erosional rates are undoubtedly higher. Actually very little is really known about the magnitude of natural coastal processes going on in the study area, and for that matter, in Alaska generally. A few qualitative reports of erosion are available from early geological reports and histories of places of habitation, but no quantitative studies have been made. Some idea of processes and volumetric changes could be obtained by comparing old aerial photographs with newer ones and by studying beach ridge patterns where present. This lack of information stems from the fact that most of the coastline is uninhabitated and undeveloped, and erosion has not caused a significant impact or problem. Erosion only becomes a problem where people inhabit or use the coastline. In 1970-1971, the U.S. Army Corps of Engineers conducted a survey of Alaska's shore erosion problems as part of an overall National Shoreline Study for the entire United States (U.S. Army Corps of Engineers 1971). Within the study area, five villages reported having erosion problems (Figure 62 and Table 20). Apparently the current beach erosion problem at the Kodiak villages was caused by the 1964 earth- quake, as the Kodiak area lies directly along the axis of maximum subsidence (Figure 63). This subsidence subjected the shoreline to an acceleration of erosional processes. Details concerning the nature of the specific problem at each village can be obtained from the U.S. Corps of Engineers. To date, only study of the shoreline erosion problems at Port Lions has been authorized and is currently being conducted by the Corps. 59° 58° 57° 55° 164° 162° 160° 156° 154° igure 62. Active erosion areas and villages listed as having water front erosion problems, Western Gulf of Alaska (from U.S. Army Corps of Engineers 1971). 164° 162° 160° 158° 156° 150° HHHHH} active EROSION AREAS 154° 152° 150° OL) 171 Table 20. List of villages in Western Gulf of Alaska reported to have coastal erosion problems. See Figure 62 for location of villages (from U.S. Army Corps of Engineers 1971). Village Erosion Miles of Coast Affected Chignik Maybe 1.0 Karluk Yes 1.0 Larsen Bay Yes 1.0 Old Harbor Yes 1.0 Port Lions Yes 0.5 172 14e° 144° 142° a _ a - - T T Fairbanks EXPLANATION a a Isobase contour, showing uplift (+) or subsidence (—) in feet Dashed where approximately lo- cated; dotted where inferred —— Approximate axis of maximum subsidence SAVY Possible zone of slight uplift (less than 2 ft) U.S. Coast and Geodetic Survey first order level net * Active or dormant volcano | i FAULT : Middleton i sland | 47 i 1 | Bee ai. ~ 74 ODI A we CROSS minas 50 100 150 MILES Co er , 3 Sngtet etn . 0 50 100 150 KILOMETERS 4 ' boi L SUBMARINE CONTOURS IN FEET 1 f Figure 63. Map showing the distribution of tectonic uplift and subsidence in south-central Alaska (from Plafker 1972). 173 Literature Cited Alaska Division of Geological and Geophysical Surveys. 1973. Annual Report 1972, State of Alaska, Department of Natural Resources. 57 p. Atwater, T. 1970. "Implications of Plate Tectonics for the Cenozoic Tectonic Evolution of Western North America." Geological Society of America Bulletin 81:3513-3536. Atwood, W.W. 1911. Geology and Mineral Resources of Parts of the Alaska Peninsula, U.S. Geological Survey. Bulletin 467. 137 p. Barnes, D. F. 1967. Four Preliminary Gravity Maps of Parts of Alaska. U.S. Geological Survey. Open-file report No. 278. Berg, H. C. and E. H. Cobb. 1967. Metalliferous Lode Deposits of Alaska. U.S. Geological Survey. Bulletin No. 1246. 254 p. Biggar, N. 1971. Thermal Springs of Alaska (Map). Geophysical Institute and Geology Department, University of Alaska, Fairbanks. Bortnikov, V. S. 1970. "Mineral Composition of the Coarse Silt Fraction of Recent Sediments in the Northwestern Part of the Gulf of Alaska." In: Soviet Investigations in the Northeast Pacific. Part V. P.A. Moiseev, ed. Transl. by Israel Program for Scientific Translations. Jerusalem. pp. 77-82. Burk, C. A. 1965. Geology of the Alaska Peninsula--Island Arc and Continental Margin. Geological Society of America Memoir 99, Pts. 1-3. 250 p. Capps, S.R. 1922. Recent Investigations of Petroleum in Alaska; Cold Bay District U.S. Geological Survey. Bulletin No. 739-C. pp. 77-116. Capps, S. R. 1937. Kodiak and Adjacent Islands, Alaska. U.S. Geological Survey. Bulletin No. 880-C. 73 p. Clark, A. L., and W. R. Greenwood. 1972. Geochemistry and Distribution of Platinum-Group Metals in Mafic to Ultramafic Complexes of Southern and Southeastern Alaska. U.S. Geological Survey. Prof. Paper No. 800-C. pp- C157-C160. Clark, A. L., H. C. Berg, E. H. Cobb, G. D. Eberlein, E. M. MacKevett, Jr., and T. P. Miller. 1972. Metal Provinces of Alaska. U.S. Geological Survey. Open-file report No. 534. Coats, R. R. 1950. Volcanic Activity in the Aleutian Arc. U.S. Geological Survey. Bulletin No. 974-B. pp. 35-49. 174 Cobb, E. H. 1972. Placer Deposits of Alaska. U.S. Geological Survey. Open-file report No. 508. Cobb, E.H. 1972a. Metallic Mineral Resources Map of the Afognak Quadrangle, Alaska. U.S. Geological Survey. Miscellaneous Field Studies Map MF-470. 1972b. Metallic Mineral Resources Map of Chignik Quadrangle. MF-374. 1972c. Cold Bay Quadrangle, MF-441. 1972d. Karluk Quadrangle, MF-459. 1972e. Kodiak Quadrangle, MF-460. 1972f. Mt. Katmai Quadrangle, MF-461. 1972g. Port Moller Quadrangle, MF-443. 1972h. Trinity Islands Quadrangle, MF-468. Cobb, E.H. 1973. Index of Metallic Mineral Deposits of Alaska Compiled from Reports in Open-Files of the U.S. Geological Society and U.S. Bureau of Mines through 1972. U.S. Geological Survey. Open-file report No. 564. Coulter, H. W., D. M. Hopkins, T. N. V. Karlstrom, T. L. Pewe, C. Wahrhaftig, and J. R. Williams. 1965. Map Showing Extent of Glaciations in Alaska. U.S. Geological Survey. Misc. Geological Investigations Map I-415. Eakins, G. R. 1970. Mineralization Near Stepovak Bay, Alaska Peninsula, Alaska. State of Alaska, Division of Mines and Geology. Special report No. 4. Eakins G. R. 1972. Mineral Exploration in Alaska in 1972. Alaska Division of Geological and Geophysical Surveys (preprint of paper presented at Northwest Mining Assoc. Convention, Dec. 1-2, 1972. Spokane, Wash.) Forbes, R. B. In Press. The Volcanoes of Katmai. University of Washington Press, Seattle, Washington. Gates, G. O., A. Grantz, and W. W. Patton, Jr. 1968. Geology and Natural Gas and Oil Resources of Alaska. American Association of Petroleum Geologists Memoir 9. pp. 3-48. Gershanovich, D. E. 1968. "New Data on the Geomorphology and Recent Sediments of the Bering Sea and the Gulf of Alaska." Marine Geology 6 (4): 281-296. 175 Gershanovich, D. E. 1970. ''Principal Results of Latest Investigations of Bottom Relief and Sediments in Fishing Grounds in the North Pacific Ocean." In: Soviet Fisheries Investigations in the Northeast Pacific. Part V. P. A. Moiseev, ed. Transl. by Israel Program for Scientific Translations. Jerusalem. 1972. pp. 7-34 Gershanovich, D. E., B. N. Kotenev, and V. N. Novihov. 1964. "Relief and Bottom Sediments of the Gulf of Alaska." In: Soviet Fisheries Investigations in the Northeast Pacific. Part III. P.A. Moiseev, ed. Transl. by Israel Program for Scientific Translations. Jerusalem. 1968. pp. 74-125. Godwin, L. H., L. B. Haigler, R. L. Rioux, D. E. White, L. J. P. Muffler, and R. G. Wayland. 1971. Classification of Public Lands Valuable for Geothermal Steam and Associated Geothermal Resources. U.S. Geological Survey. Circular 647. Grantz, A. 1963. Aerial Reconnaissance of Outer Shumagin Islands. U.S. Geological Survey. Professional Paper 475-B. pp. 106-109. Hansen, W. R. and Eckel, E. B. 1971. "Setting and Effects of the Earth- quake."In: The Great Alaska Earthquake of 1964, Geology. National Research Council, National Academy of Sciences, Washington, D.C. pp._5-43. Harrison, C. R., P. L. Dobey, G. Gryc, M. Erwin, and E. W. Scott. 1973. "Developments in Alaska in 1972."" American Association of Petroleum Geologists Bulletin. 57(8):1406-1420. Jones, D. L., and S. H. B. Clark. 1973. "Upper Cretaceous (Maestrichtian) Fossils from the Kenai-Chugach Mountains, Kodiak and Shumagin Islands, Southern Alaska." U.S. Geological Survey Journal of Research. 1(2):125-136. Karlstrom, T.N.V. 1964. Quaternary History of the Gulf of Alaska Continental Shelf. U.S. Geological Survey. Prof. Paper No. 443. Karlstrom, T. N. V., and G. E. Ball, eds. 1969. The Kodiak Island Refugium, Its Geology, Flora, Fauna, and History. Ryerson Press. Toronto. 262 p. Karlstrom, T.N.V., et al. 1964. Surficial Geology of Alaska. U.S. Geological Survey, Misc. Geological Inventory Map I-357. Kelleher, J. A. 1970. "Space-Time Seismicity of the Alaska-Aleutian Seismic Zone." J. Geophysical Res. 75(29):5745-5756. Keller, A.S. and H.N. Reiser, 1959. Geology of the Mount Katmai area, Alaska. U.S. Geological Survey. Bulletin 1058-G. Kennedy, G. C., and H.H. Waldron, 1955. Geology of Pavlof Volcano and Vicinity, Alaska. U.S. Geological Survey. Bulletin 1028-A, pp. 1-19. Kienle, J. 1971. "Gravity and Magnetic Measurements over Bowers Ridge and Shirshov Ridge, Bering Sea." J. Geophy. Res. 76(29):7138-7153. 176 Knappen, R.S., 1929. Geology and Mineral Resources of the Aniakchak District, Alaska. U.S. Geological Survey. Bulletin 797-F. pp. 161-227. Kulm, L. D., Von Huene, R., et al. 1973. "Tectonic Summary of Leg 18." In: Initial Reports of the Deep Sea Drilling Project. XVIII. U.S. Gov't. Printing Office, Washington, D.C. Lahr, J.C., R.A. Page, and J.A. Thomas 1974. Catalog of Earthquakes in South Central Alaska, April-June 1972. U.S. Geological Survey. Open-file Report. 30 p. Macdonald, G. A. 1972. Volcanoes. Prentice-Hall, Englewood, N. J. 510 p. Maddren, A. G. 1919. The Beach Placers of the West Coast of Kodiak Island Alaska. U.S. Geological Survey. Bulletin No. 692. pp. 299-327. Mather, K.P. 1925. Petroleum on Alaska Peninsula, Mineral Resources of the Kamishak Bay Region. U.S. Geological Survey. Bulletin 773-D, pp. 159-182. McGee, D.L. 1972. Kodiak Island and Vicinity, Alaska, Geology and Mineral Resources. Alaska Division of Geological and Geophysical Surveys. Department Natural Resources. Open-file report No. 18. Miller, T. P. 1973. Distribution and Chemical Analyses of Thermal Springs in Alaska. U.S. Geological Survey. Open-file map No. 570. Miller, D. J., T. G. Payne, and G. Gryc. 1959. Geology of Possible Petroleum Provinces in Alaska. U.S. Geological Survey. Bulletin No. 1094. Moore, G. W. 1967. Preliminary Geologic Map of Kodiak Island and Vicinity, Alaska. U.S. Geological Survey. Open-file report No. 271. Moore, G. W. 1969. New Formations on Kodiak and Adjacent Islands. U.S. Geological Survey. Bulletin No. 1274-A. pp. A27-A35. Moore, J.C. 1972. "Uplifted Trench Sediments: Southwestern Alaska-Bering Shelf Edge."" Science 175:1103-1105. Moore, J. C. 1973. "Cretaceous Continental Margin Sedimentation, Southwestern Alaska." Geological Society of America Bulletin. 84:595-614. Moxham, R.M. 1951. Pumice Deposits in the Alaska Peninsula-Cook Inlet Region, Alaska. U.S. Geological Survey. Unpublished manuscript. Piper, D. J. W., von Huene, R., J. R. Duncan. 1973. "Late Quaternary Sedimentation in the Active Eastern Aleutian Trench." Geology 1(1):19-22. Pitman, W. C., III, and D. E. Hayes. 1968. ''Sea-Floor Spreading in the Gulf of Alaska." J. Geophys. Res. 73(20):6571-6580. 177 Plafker, G. 1971. "Possible Future Petroleum Resources of Pacific-Margin Tertiary Basin, Alaska." In: American Association of Petroleum Geologists Memoir 15. pp. 120-135. Plafker, G. 1972. "Tectonics." In: The Great Alaska Earthquake of 1964, Geology. National Research Council, National Academy of Sciences. Washington, D.C. pp. 47-122. Powers, H.A. 1958. "Alaska Peninsula--Aleutian Islands" In: Landscapes of Alaska. H. Williams, ed. University of Calif. Press. pp 61-75. Rieger, S. 1973. Exploratory Soil Survey, Alaska (Unpublished maps and notes). U.S. Dept. of Agriculture. Soil Conservation Service. Palmer, Alaska. Reiger S., and R. E. Wunderlich. 1960. Soil Survey and Vegetation of Northeastern Kodiak Island Area, Alaska. U.S. Department of Agriculture, Soil Conservation Service and U.S. Department of the Interior, Bureau of Land Management. Alaska Experiment Station. Soil Survey Series 1956, No. 17. Shor, G. G., Jr. 1962. "Seismic Refraction Studies Off the Coast of Alaska, 1956-1957." Seismol. Soc. Am. Bull. 52:37-57. Shor, G. G., Jr., and R. von Huene. 1972. "Marine Seismic Refraction Studies near Kodiak, Alaska." Geophysics 37(4):697-700. Smith, W.R. 1925. Petroleum on Alaska Peninsula, The Cold Bay District. U.S. Geological Survey. Bulletin 773-D, pp. 183-208. Smith, W.R. and A.A. Baker. 1924. The Cold Bay-Chignik District. U.S. Geological Survey. Bulletin 755-D, pp. 151-218. Swainbank, R. C. 1973. Mineral Commodity Map of Alaska. Mineral Industry Research Laboratory, University of Alaska, Fairbanks. Sykes, L. R. 1972. "Seismicity as a Guide to Global Tectonics and Earthquake Prediction." Tectonophysics. 13(1-4). U.S. Army Corps of Engineers. 1961. Terrain Study of Alaska, Part III: Soils. Department of the Army, Office, Chief of Engineers. Washington, D.C. U.S. Army Corps of Engineers. 1971. National Shoreline Study. North Pacific Division. U.S. Geological Survey. 1972. The Status of Mineral Resources Information on the Major Alaska Native Claims Act of 1971. U.S. Geological Survey, Open-file report 546. 164 p. von Huene, R. 1966. "Glacial Marine Geology of Nuka Bay, Alaska and the Adjacent Continental Shelf." Marine Geology 4:291-304. 178 von Huene R. 1972. "Structure of the Continental Margin and Tectonism at the Eastern Aleutian Trench." Geological Society of America Bulletin 83: 3613-3626. von Huene, R., and G. G. Shor, Jr. 1969. "The Structure and Tectonic History of the Eastern Aleutian Trench." Geological Society of America Bulletin 80:1889-1902. von Huene, R., R. J. Malloy, G. G. Shor, Jr., and P. St. Amad. 1967. "Geologic Structures in the Aftershock Region of the 1964 Alaskan Earthquake." J. Geophys. Res. 72:3649-3660. von Huene, R., E. H. Lathram, and E. Reimnitz. 1971. "Possible Petroleum Resources of Offshore Pacific-Margin Teritary Basin, Alaska." American Association of Petroleum Geologists. Memoir 15. pp. 136-159. von Huene, R., G. G. Shor, Jr., and R. J. Malloy. 1972. "Offshore Tectonic Features in the Affected Region." In: The Great Alaska Earthquake of 1964: Oceanography and Coastal Engineering. National Academy of Sciences. Washington, D.C. pp. 266-289. Waldron, H.H. 1961. Geologic Reconnaissance of Frosty Peak Volcano and Vicinity, Alaska. U.S. Geological Survey Bulletin 1028-T, pp. 677-708. Wentink, T. In Press. Wind Power Potential of Alaska. Pt. I. Surface Wind Data from Specific Coastal Sites. Geophysical Institute Report UAG-R-225. University of Alaska, Fairbanks. Wilcox, R. E. 1959. Some Effects of Recent Volcanic Ash Falls, with Special Reference to Alaska. U.S. Geological Survey. Bull. No. 1028-N pp. 409-476. Wright, F. F. 1970. An Oceanographic Reconnaissance of the Waters Around Kodiak Island, Alaska. Institute of Marine Science, University of Alaska, Fairbanks Report No. 1270-19. 23 pp. Wright, F. F., G. D. Sharma, and D. C. Burbank. 1973. ERTS-1 Observations of Sea Surface Circulation and Sediment Transport, Cook Inlet, Alaska. Symp. on Significant Results Obtained from the Earth Resources Technology Satellite-l, Sec. B. pp. 1315-1322. 179 vI. HyYpRoLocy! INTRODUCTION The study area is characterized by a steep, rugged, inlet indented coast with scattered lowlands in which glacial and alluvial deposits occur. Most streams are short (none more than 30 to 50 km.) and have narrow floodplains, steep gradients, and small drainage basins. The area is within the maritime climatic zone, which is characterized by high precipitation and mild temperatures. It is essentially free of permafrost except possibly for crestal areas of the Aleutian Range and Kodiak Island. Portions of some of the higher peaks still contain glaciers. Hydrologic information for the area is scarce and includes only limited data from a few short-term surface water gaging stations on Kodiak Island, data from a few water wells mostly on Kodiak Island, and a few scattered bits of water quality data. Little data are available for the Alaska Peninsula. The U. S. Geological Survey, Anchorage, has conducted limited and sporadic studies for Kodiak and the Kodiak Borough over the past 10 years to help resolve their water supply problems. SURFACE WATER Surface water stations in the study area are limited to the Kodiak area. The location, description, and status of these stations are presented in Figure 64 and Table 21. Data from these stations have been published in a series of U. S. Geolgoical Survey publications, the most recent being "Water Resources Data for Alaska, 1971" (U. S. Geological Survey 1972). Pertinent information from this publication for the Kodiak stations is summarized in Tables 22, 23, and 24. Exposed bedrock and thin soils throughout most of the area, plus the general lack of aquifers, cause runoff rates to be among the highest in the state. For most of the area the mean annual runoff probably averages about 4 cubic feet per second per square mile (c.f.s./mi.2) (44 liters per second per square Eilometer=1 .s./km.2) (Figure 65). It may reach as high as 8 c.f.s./mi.? (88 1.s./km. 2) on the southeast side of Kodiak Island ang in higher elgvations, and it probably is much less than 4 c.f.s./mi2 (44 l.s./km.2) in small, low-lying basins. Total discharge for Kodiak and Afognak Islands is reported as 37,600 c.f.s./(1.06 million liters per second). Mean annual peak runoff for the area (an average of the highest runoff recorded each year) probably averages about 50 c.f.s./mi.2 2530 1.s./km.2), but may be as high has 100 c.f.s./mi.2 (1100 1.s./km.2) for southeast Kodiak Island and higher elevations (Figure 65). These are some of the highest flood discharge rates in the state. Data on maximum lmuch of the narrative for this section is adapted from Feulner 1973a, 1973b and Feulner et al. 1971, 1972. 164° Figure 64, 162° 160° Location of surface water stations, Western Gulf of Alaska (from Interagency Technical Committee for Alaska 1970 and Childers 1970). 158° 156° 156° 154° 152° 150° 150° o8t Sta. Station Type of No. Locaticn - stream Status Type Data Purpose Agency Responsible 1. Uganik R. Existing Continuous Physical, Baseline U.S.G.S. Daily Chemical Hydrologic Data 2. Myrtle Ck. Existing Continuous Physical, Baseline U.S.G.S., Ak. Dept. of Hwys. Daily Chemical Hydrologic Data 3. Black Canyon Ck. Existing Periodic Physical Flood U.S.G.S., Ak. Dept. of Hwys. Visit Information 4. Red Cloud Ck. Tributary Existing Periodic Physical Flood U.S.G.S., Ak. Dept. of Hwys. (near Kodiak) Visit Information 5. Kalsin Bay Tributary Existing Periodic Physical Flood U.S.G.S., Ak. Dept. of Hwys. (near Kodiak) Visit Information 6. Middle Fork Pillar Ck. Discon- Continuous Physical, Water U.S.G.S., Kodiak I. Borough (near Kodiak) tinued Chemical Supply 1970 7. Dog Salmon Cr. (near Proposed Continuous Physical, Baseline U.S.G.S. Ayakulik) (Discon- Chemical Hydrologic tinued) 8. L. Kitoi Cr. (near Discon- Periodic - - - tinued Visit - - - 9. Terror R. (upstream) Discon- Continuous - - - tinued 10. Terror R. (mouth) Discon- Continuous - - - tinued ll. Spiradon L. (near Discon- Continuous - - - Larsen Bay) tinued Table 21. Surface water programs, Western Gulf of Alaska (from Inter-Agency Technical Committee for Alaska 1970 and U.S. Geological Survey 1972). I8t Sta-} Drainage] Period Discharge - Period of Record Discharge - Water Year 1971 (cfs) : tion} Area of Average Runoff | Maximum ]| Date of Maximum | “finimum Runoff No. | (sq.mi.)} Record (cfs) (cfs/mi~) (cfs) Maximum | Total Mean Peak Monthly ‘Monthly (cfs/mi2) r T + T T 1. 123 951-1971 664 5.4 13,700 19/03/52 289,261 792 5,270 4,940 150 6.44 - +— +_ {| }_ tt t 4_ 2. 4.74 1963-1971 45.3 9.6 1,110 9/14/69 18,028 | 49.4 694 443 53.9 10.4 | | + | *: 1.51 963-1971 590 8/29/71 ~—— +t 5. 2.35 1963-1969 259 9/14/69 Lt _ Table 22. Streamflow data, Kodiak area (from U.S. Geological Survey 1972) Z8I (se9013ep 9) eanjeszedusy, Hd (soywosoTW) aouejyonpuog osTsToedg (1/8W) sseupieyH 3}eUOqIeOUON (1/3u) (8W ‘e9) ssetpaeq (1/3m) SPTTOS peaTossTd (1/8m) 23813 1N (1/3m) eptionyTg peatosstq (1/8u) eptr0T YO (1/8) 2e3e3TNS (1/8u) ezeUuogieoTg (1/8u) untssejog (1/3u) wntpogs (1/3w) untseuze_ peatosstq (1/3W) wntoTe) peatosstq (1/8n) Uoizy peatosstq (1/3W) eOTTTS (cfs) Dischg. Date Sta No. N ~ w on” N on wn om sa aoa 4 oa) a) a) ° oO wo oe wy N ao 4 N +t ~ as +0 N SCOnONnDaARD NAS N “” on ” oo oo ” ao N co N ao wn ral a oO Oo oo a N Oo al om + a) ° a + ao oO ~ Oo + w sw o CONLDDHDH mMONDSTNMO Nn AN - | HOCO aA AAA hh Oe ~~ SSN EE —~OomMmMonrn~nMnNna ON BAA NANN ~~ SS Se ABNOR RH NNHM™M an Water quality data (chemistry) Kodiak area, water year 1971 (from U.S. Geological Survey 1972) Table 23. 183 Station Date Temp. Discharge Suspended Suspended No C Degrees (cfs) Sediment (mg/1) Sediment Discharge Tons/day 1 1/6/71 0 276 2 1.5 1 5/26/71 5.5 760 3 6.2 1 7/21/71 7.0 2460 8 53 2 10/13/70 7.0 22 1 0.06 2 11/10/70 4.5 186 3 1.5 2 11/11/70 4.5 248 9 6.0 2 1/5/71 1.0 51 1 0.14 2 3/18/71 0.5 3.8 1 0.01 2 5/25/71 0.5 301 94 76 2 7/21/71 6.5 221 31 18 2 9/8/71 7.0 54 3 0 .44 Table 24. Water quality data (suspended sediment), Kodiak area, water year 1971 (from U. S. Geological Survey 1972) vst Figure 65a. Mean annual runoff in cu. ft./sec./sq. mile (from Feulner et al. 1971). eset Figure 65b. Mean annual peak runoff in cu. ft./sec./sq. mile (from Feulner et al- 1971). asst Figure 65c. Mean annual low monthly runoff in cu. ft./sec./sq. mile (from Feulner et al. 1971). osst 186 known floods in the Kodiak area are presented in Table 25. In addition to flooding caused by rapid and high peak runoff during storms, floods may also occur during cold winter months when ice jamming causes higher flood stages than normal. In small, low basins or basins with lakes, the peak, runoff can be significantly reduced to rates of 10 c.f.s./mi.~ (100 1.s./km.*) or lower. Mean annual low monthly runoff (an average of fhe lowest runoff recorded each month) probably averages 1 c.f.s./mi.“ (11 1.s./km.2) or less (Figure 65). Winter precipitation occurs mostly as snow, but generally enough snow melt or rain occurs to sustain stream flow. During long, cold winters, however, stream flows will drop quite low and cause water shortages for communities depending on them for water. Winter snowpack and a few glaciers provide most of the water storage. The area contains only two lakes having a surface area over 25 sq. km.--Chignik Lake near Chignik on the Alaska Peninsula and Karluk Lake on southwest Kodiak Island. Water quality of streams in the area is good. Most streams are low in dissolved solids and appear to range between 17 milligrams per liter (mg./1.) at the outlet to Terror R. (northwest side of Kodiak I.) and 45 mg./1. at Monashka Creek near Kodiak. Most of the surface streams near the coast contain water of a sodium chloride or sodium bicarbonate type. A few lakes may have high iron content waters, that may be corrosive to iron piping if untreated. Although no stream sediment data has been collected for the Alaska Peninsula area, some generalizations can be made. During summer months, streams draining the larger ice fields on the Peninsula and also areas with recent ash deposits like Katmai may have suspended sediment concen- trations as high as 2000 mg./1., while streams draining small mountain glaciers or high mountains probably carry between 5 and 500 mg./1. Streams draining the lowlands carry only small quantities. Winter concentrations probably are less than 10 mg./1., although some streams on the Peninsula may be slightly higher. Surface water temperatures probably range between 1 degees C and 6 degrees C (33 degrees F-42 degrees F), although shallow lakes could range higher. GROUNDWATER Most of the area is considered to have poor potential for large groundwater supplies, generally because of shallow bedrock and a lack of large amounts of surficial water-bearing materials. Limited amounts of groundwater probably are available in low-lying areas covered by alluvial or glacial deposits. Some groundwater is available locally from fractures in bedrock. 188 Exploration for groundwater has not been extensive, and only a few wells have been drilled, mostly near Kodiak, Cold Bay, and King Cove. The latter two locations have ‘produced useful quantities, but there are little actual data available about~ the yields of th se wells. Springs are found throughout the area, but have not been cataloged. Several communities and canneries use springs as a water supply, although yields are small. Groundwater quality of the area is based mainly on data from the few wells in the Kodiak area and varies from 44 to 1,604 mg./1., although a more representative range of values may vary from 150 mg./1. to 250 mg./1. Shallow wells drilled in alluvium near streams generally have acceptable water quality, although some high iron content may be encountered. Bedrock wells or wells near the coast may contain excessive amounts of sodium chloride, while some wells from the eastern Alaska Peninsula may have excessive calcium, sodium, and bicarbonate ions. Groundwater is usually harder than surface water. Quality of spring water appears to be good. Analysis of those springs on Kodiak Island indicates acceptable quality and low dissolved solid and ion content values. Limited data indicate groundwater temperature ranges between 2 and 13 degrees C with the higher ranges coming from shallow wells near Kodiak. Maximum known floods Discharge Station Drainage Area Period of Records Date Flow Rate Runoff No. (sq. miles) (years/dates) (cfs) (cf£s/mi2) 1 123 18(1950-68) 10/3/52 13,700 111 2 4.74 6 (1962-68) 8/30/63 1,080 228 4 1.51 5 (1962-67) 8/30/63 570 337 7 72.9 2(1959-61) 9/24/61 777 10.6 8 2.63 1(1960-61) 1/20/61 42 16.0 9 15.0 7(1961-68) 8/29/63 4,590 306 10 46.0 5 (1963-68) 9/26/66 3,820 83.0 ll 23.3 4(1961-65) 3/27/64 189 8.11 Table 25. Maximum known floods, Kodiak area. (See Figure 24 and Table 21 for location and description of stations (from Childers 1970). LZ8T 189 LITERATURE CITED Childers, J.M. 1970. Flood Frequency in Alaska. U.S. Geological Survey, Water Resources Division, Alaska District, open file report. 30 p. Feulner, A. J. 1973a. Summary of Water Supplies at Alaska Communities, Southcentral Region, Kodiak-Shelikof Subregion. Joint Federal- State Land Use Planning Commission, Resource Planning Team, unpublished. 24 p. Feulner, A. J. 1973b. Summary of Water Supplies at Alaska Communities, Southwest Region, Aluetian Subregion. Joint Federal-State Land Use Planning Commission, Resource Planning Team, unpublished report. 13 p. Feulner, A. J., J. M. Childers, and V. W. Norman. 1971. Water Resources of Alaska. U. S. Geological Survey, Water Resources Division, Alaska District, open file report. 60 p. Feulner, A. J., J. M. Childers, and V. W. Norman. 1972. Water Resources of Alaska. U. S. Geological Survey, Water Resources Division, Alaska District, unpublished report. Interagency Technical Committee for Alaska. 1970. Alaska Ten Year Comprehensive Plan for Climatologic and Hydrologic Data. Sponsored by Hydrology Committee, Water Resources Council. U. S. Geological Survey. 1972. Water Resources Data for Alaska, 1971. Water Resources Division, Anchorage, Alaska, 319 p. 190 VII. BIOTA OF THE WESTERN GULF OF ALASKA MARINE BACTERIA Bacteria in the marine environment, although recognized as important in organic matter decomposition and nutrient recycling, are seldom a priority in oceanographic investigations. Within the study area, only one series of bacterial observations was conducted in the summer of 1960 (Faculty of Fisheries 1961). Positive tests for hydrogen sulfide production, nitrate reduction and sulfate reduction were recorded at depths of less than 50 m. Negative tests were recorded for all depths exceeding 50 m. Sparse data precludes any conclusions other than possibly higher bacteria concentration in surface waters. PLANKTON Phytoplankton Data on planktonic primary producers in the Western Gulf of Alaska have been collected largely by the National Marine Fisheries Service (formerly the U.S. Bureau of Commercial Fisheries); the Institute of Marine Science (University of Alaska); the Department of Oceanography (University of Washington), and the Faculty of Fisheries (Hokkaido University). As one moves toward shore, the volume of data available decreases. Cooney (1972) summarized the North Pacific data, and indicates total annual primary production may be two to four times greater near the coast than in the open ocean. Along the coast, nearshore current patterns may produce marked variations between adjacent locations. Japanese data (Faculty of Fisheries 1961) and McRoy et al. (1972) record primary productivity--the rate at which new organic matter in the form of phytoplankton is created--nearest,the coast, at the surface, ranging from 0.15 to 1.95 mg. carbon/m. 3yhr. south of Unimak Island and from 0.39 to 2.80 mg. carbon/m. Syhr. eastward along the continental slope to the boundary of the study area (Figure 66). Integrated for the gentire water column, productivity ranges from 18 to 408 mg. carbon/m. 2/day south of Unimak Island. These values are generally lower ghan Bering Sea figures and are below the value of 1.0 gm. carbon/m.“/day accepted as indicative of active upwelling (Hood et al. 1971). Maximum values eastward over the continental slope and shelf may approach upwelling levels. These values, recorded during June and July, probably represent the highest productivity achieved by this community. Roden (1967) stated that winter productivity in the Gulf of Alaska is very low. @ 0.01-1.00 MG. CARBON/M3/HR. @ |.00-2.00 mG. CARBON/M/HR. @ 2.:00-3.00 MG. CARBON/M/HR. Figure 66- Primary productivity in the Western Gulf of Alaska (from Faculty of Fisheries 1961; McRoy et al+ 1972). T6T 192 The standing crop of phytoplankters--the amount of organic matter in the form of phytoplankton measureable at a point in time--at the surface, measured by the Faculty of Fisheries (1972) in addition to the same two sources previously cited, was found to be highest in the Unimak area (0.2-1.6 mg. chlorophyll a/m.>) and decreases to the east (0.09-0.50 mg. chlorophyll a/m.>). {f these limited measurements were to be accepted as characteristic of this region, the Unimak locale experiences a lesser loss of phytoplank- ters (possibly to grazing by zooplankton), and thus develops a larger standing crop. Eastward, productivity may be higher, but loss (possibly zooplankton grazing) appears to increase even more, resulting in a lower standing crop of phytoplankters. Species reported as dominant (Faculty of Fisheries 1957; 1961; 1965) are almost always diatoms with dinoflagellates mentioned once (Table 26). Microplankton were not surveyed for species in these studies, but could contribute significantly to primary productivity. In a seven-year study of diatoms at Scotch Cap (Unimak Island), Cupp (1937) identified 87 species and 36 genera. Temperate neritic species were most numerous with Asterionella japonica, Thalassiosira nordenskioldii, Chaetoceros debilis and Biddulphia aurita of major importance. November through March was the period of lowest production of diatoms. The spring maximum had its peak in April and May with a smaller autumn maximum in September. Cupp reported 21 species and 6 genera of dinoflagellates with no large populations in comparison to diatoms. Following the 1970 Kodiak oil pollution incident, the U.S. Bureau of Commercial Fisheries (now the National Marine Fisheries Service) indicated its intention to: "Undertake research at earliest possible date on...phytoplankton species composition, and primary productivity within the...Kodiak area(s)" (Federal Water Quality Administration 1970). Little information has been collected on these matters to date. A number of offshore phytoplankton and primary productivity studies were summarized by Cooney (1972), but so little inshore data exists that their application would be highly. speculative. Figure 67 illustrates Northeastern Pacific phytoplankton productivity as summarized by the Food and Agriculture Organization of the United Nations (1972). TABLE 26 Dominant Phytoplankton Species of the Western Gulf of Alaska (from Cupp 1937; Faculty of Fisheries 1957, 1961, 1965). WOMWNADUWNHWNH . Achnanthes sp. . Actinoptychus undulatus . Asterionella japonica . A. kariana . Asteromphalus heptactis . Aulacodiscus argus Diatoms Bacteriastrum delicatulum . Biddulphia aurit . B. longicruris . B. mobiliensis . B. pulchella . Cerataulina bergonii . Chaetoceros affinis . C. compressus . C. concavicornis a « constrictus . C. curvisctus . danicus . debilis Cc C. constrictus. . C. convolutus C C C . C. decipiens . C. didymus . C. furcellatus . C. laciniosus . C. lorenzianus 44. 45. 46. 47. 48. 49. 50. Sl. 52. 53. 54. 55. 56. OTs 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. Denticula marina Ditylum brightwellii Eucampia_zoodiacus Fragilaria islandica F. striatula Grammatophora marina Isthmia nervosa Lauderia borealis Leptocylindrus danicus L. minimus Licmophora_lyngbyei Melosira sulcata Navicula sp. Nitzschia closterium N. delicatissima N._ pungens N. scriata Pleurosigma sp. Rhabdonema arcuatum Rhizosolenia alata R. delicatula R. obtusa R._semispina R. setigera R. stolterfothii 193 26. 27. 28. 29, 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. POUMNADAUNFWNHE He TABLE 26, Continued. C. Mitra C. peruvianus C. pseudocrinitus C. radicans C. simplex C. similis C. socialis C. subsecundus Cocconcis sp. Corethron hystrix C. valdiviae Coscinodiscus angstii C. centralis C. excentricus C. granii C. nitidus C. radiatus Coscinodiscus polychorda Dinoflagellates . Ceratium furca . C. fusus . C. longipes . C. pentagonum . C. tripos . Dinophysis acuminata . D. acuta . D. arctica . D. caudata . D. ellipsoides » D. ovum 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. 84. 85. 86 12. 13. 14. 1S. 16. 17. 18. 19. 20. 21. 194 R. styliformus Skeletonema costatum Stephanopyxis nipponica S. palmeriana Streptotheca_thamesis Striatelia unipunctata Thalassionema nitzschioides Thalassiosira aestivalis T. condensata T. decipiens T. gravida T. nordenskioldii T. pacifica T. rotula T. subtilis Thalassiothrix frauenfeldii T. longissima . Trepidoneis sp. D. rotundata Gonyaulax sp. Peridinium crassipes P. depressum P. divergens P. ovatum P. pentagonum P. steinii Phalacroma rudgei Prorocentrum micans 165° 160° 155° 150° 145° 140° 135° 130° ALASKA : | Bee ee ; CANADA 60° 160° aN 55° : 50° 50° UZ) 100-150 MG. CARBON/M7/ DAY 150-250 MG. CARBON/M“/ DAY 250-500 MG. CARBON/M7/ DAY MORE THAN 500 MG. CARBON/M“/DAY 165° 160° 155° 150° 145° 140° 135° 130° Figure 67. Phytoplankton productivity in the North Pacific Ocean (from Food and Agriculture Organization of the United WG Nations 1972). 61 196 Zooplankton and Micronekton In addition to the same sources cited for phytoplankton, the zooplankton data from a multinational oceanographic venture (NORPAC) in 1955 have been compiled for the North Pacific. Cooney (1972), in summarizing available information on the Northeast- ern Pacific, stated that zooplankton respond more instantaneously to phytoplankton blooms in the open ocean, where deep water forms are readily accessible through vertical migration. In coastal areas, deeper waters are not available to harbor zooplankton; thus, phytoplankton blooms must await current action to provide zooplankton grazers. The NORPAC Committee atlas (1960) indicates two locales within the study area--northeast of Kodiak and southwest of the Shumagin Islands--of maximum zooplankton density exceeding 400 cm.3/1,000 cu. m. The entire study area exhibits generally higher zooplankton densities than surrounding areas. Densities decrease as one moves east, west, or offshore (Figure 68). Gulland (1970) noted that zooplankton density is quite variable from year to year. In the coastal North Pacific, copepods compose approximately 75 percent of the zooplankton biomass throughout the year, while chaetognaths, amphipods and euphausiids form most of the remainder, Gulland states. His findings are supported by data on species identified during Japanese cruises (Table 27) within the study area (Faculty of Fisheries 1957; 1961; 1965; 1967; 1972). Standing crops measured at the surface on Japanese cruises were generally lower in the Unimak area (21 to 411 gm. wet wt./1,000 cu. m.), and higher eastward (107 to 1611 gm. wet wt./1,000 cu. m.) over the outer continental shelf and slope (Figure 69). It is expected that seasonal abundance of zooplankton would closely follow phytoplankton with maximum abundance from June through August and minimum from December through February. The importance of currents in bringing oceanic species into this region is emphasized by the recognition of Calanus plumchrus, C. cristatus, and Eucalanus bungii in waters over the continental slope south and west of the Shumagin Islands. LeBrasseur (1965) has mapped the occurrence of individual species at various oceanographic stations occupied between 1956 and 1964 in the northeastern Pacific Ocean. Generally copepods composed more than 70 percent of the biomass except on occasion west of the Shumagin Islands and south of Chirikof Island where euphausiids and amphipods were abundant. 165° 160° 155° 150° 145° 140° 135° 130° ALASKA ' CANADA 50° 160° 55° 50° 165° 160° 155° 150° 145° 140° 135° 130° Figure 68. Zooplankton densities in cu. cm./1,000 cu. m. in the North Pacific Ocean (from NORPAC Committee 1960). £61 198 TABLE 27 Dominant Zooplankton Species of the Western Gulf of Alaska (from Faculty of Fisheries 1957, 1961, 1965, 1967, 1972) Coelenterata 1. Jellyfish Chaetognatha 1. Sagitta elegans Annelida 1. Tomopteris sp. Arthropoda Crustacea . Amphipods . Calanus cristatus . C. finmarchicus » C. plumchru . Eucalanus_bungii . Euphausia pacifica . Euthemisto libellula . Metridia lucens . M. pacifica . Thysanoessa_longipes Zoea FOU mANDUNRWNE od Mollusca Gastropoda 1. Pteropods 2. Limacina helicina 3. Clio pyramidata Chordata 1. Fish larvae @ 0-500 GM/I000 M® @ MORE THAN 500 GM/1000 M3 Figure 69. Zooplankton standing crop in the Western Gulf of Alaska (from Faculty of Fisheries 1957, 1961, 1965, 1967, 1972)+ 661 200 Sampling within the study area has been limited, scattered, and monitored primarily in summer months, which severely restricts the understanding of the dynamics within this segment of the marine community. Macroplankton collected by the International Pacific Halibut Commission during the months of December through July from 1926 to 1934 in the Western Gulf still awaits study at the Smithsonian Institution. 1! Following the 1970 oil pollution incident at Kodiak, the U.S. Bureau of Commercial Fisheries (now National Marine Fisheries Service) proposed that ''zooplankton larvae distribution and abundance studies should be immediately undertaken" (Federal Water Quality Administration 1970). Little data has been produced since this statement. Lisovenko (1964) surveyed the distribution and abundance of Pacific Ocean perch (Sebastes alutus) larvae, and identified centers of larval abundance south and east of Kodiak, extending westward above the contin- ental slope to southwest of the Shumagin Islands. The majority of the larvae were found between the surface and 100 m., and were associated with Calanoid copepods and Euphausiids. These larvae appear from late April to late May or early June in the westernmost regions. LeBrasseur (1970), in reporting larval fish collected in Canadian zooplankton samples from the northeastern Pacific Ocean, frequently recorded rockfish (Scorpaenidae), sculpin (Cottidae), ronquil (bathymas- teridae) and snailfish (Cyclopteridae) larvae offshore in the Western Gulf of Alaska. MARINE MACROPHYTES With the exception of extensive studies on eelgrass, Zostera marina, conducted by McRoy of the Institute of Marine Science, University of Alaska, higher producers have been mentioned only briefly in various marine investigations conducted within the study area. Marine Advisers, Inc. (1971), in a study of the Kodiak harbor, reported that all rocky surfaces in shallow subtidal and lower intertidal areas were rich in Alaria sp. and Laminaria sp. and that Corallina sp., Lithothamnion sp. and Lithophyllum sp. also were present. Within Three Saints Bay, southeastern coast of Kodiak Island, Nybakken (1969) found 20 species inhabiting the intertidal zone (Table 28). Oil geologists, based on submarine observations, have remarked on the general lack of vegetation in most of the Gulf of Alaska (U.S. Bureau of Land Management 1973). Kelps (Phaeophyta) are common in shallows and around most islands (McRoy 1971). A survey of kelps in Alaska, which was conducted by the United States Department of Agriculture in 1912-1914, yielded a standing stock estimate of almost 2.3 million metric tons for Western Alaska (Rigg 1915). The location lrichard S. Houbrick, Supervisor for Invertebrates Smithsonian Oceanographic Sorting Center, Smithsonian Institution, Washington, D.C. Personal communication. October 2, 1973. TABLE 28 Marine Macrophytes of the Western Gulf of Alaska (from Nybakken 1969; Druehl 1970) Thallophyta Chlorophyceae 1. Enteromorpha compressa 2. Enteromorpha intestinalis* 3. Spongomorpha sp.* 4. Spongomorpha coalita 5. Ulva sp.* Phaeopyceae (1.)Agarum cribrosum 2. Alaria crispa 3. A. fistulosa 4. A. phylaii* 5. A. praelonga 6. A. taeniata 7. A. tenuifolia (8.)Chorda filum 9. Chordaria flagelliformes* 10. Colpomenia sinuosa* (11.)Costaria costata 12. Cymathere triplicata 13. Cytoseira germinata* 14. Dictyosiphon foeniculacens* 15. Ectocarpus sp.* Rhodophyceae 1. Ahnfeltia plicata 2. Cryptosiphonia woodii* 3. Endocladia muricata 4. Halosaccion glandiforme* 5. Odonthalia floccosa* Spermatophyta Angiospermae 1. Zostera marina* 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. (26. (27. 28. 29. 30. 31. rFOWUAND RR Hedophyllum sessile Laminaria dentigera L. groenlandica L. longipes L. personata* L. platymeris* L. saccharina L. setchellii L. yezoensis ) Lessonlopsis littoralis )Macrocystis integrifoli Thalassiophyllum clathrus Nereocystis leutkeana Scytosiphon lamentana* Soranthera ulvoidae . Porphyra sp.* - Porphyra perforata . Pterosiphonia bipinnata . Rhodomela larix* . Rhodymenia palmata* . Schizymenia pacifica () - This species is at the limit of its known range within the study area. * - These species are listed by Nybakken (1969). 202 of large beds is shown in Figure 70. McRoy et al. (1969) used the Shumagin Islands for an "example location" of kelp beds within the study area. Nereocystis sp. was reported dominant at King Cove, but was observed only rarely west of this location (Scheffer, 1959). Nereocystis was found washed ashore after a storm in Otter Cove on the southeast coast of Unimak Island. Druehl (1970) delineated a distinct association of Laminariales occurring from Kodiak westward, which differs from the assemblage of species extending from Yakutat southward. A transition zone exists between Kodiak and Yakutat. The species identified within the study area are included in Table 28. Feder and Mueller (1972), summarizing studies along the intertidal Gulf of Alaska coast, distinguished between a midlittoral zone dominated by Fucus, and a zone below low tide characterized by Laminaria and Alaria on rocky coasts. When the substrate is soft mud or sand, Zostera marina may occupy the lowest zone, rather than Laminaria and Alaria. McRoy (1968) listed the location of significant eelgrass Zostera marina, communities within the study area (Figure 71). Z. marina, the only significant vascular plant inhabiting the marine environment in this study area, is distributed widely wherever a soft mud or sand substrate is available, and reaches maximum growth in shallow lagoons such as Kinzarof. In Kinzarof Lagoon, at the head of Cold Bay, McRoy (1970) found the highest standing stock of eelgrass measured in Alaska. His calculations for standing stock were 1840 gm. dry wt./m.2on almost 9 million sq. m. or over 150,000 metric tons of eelgrass in this lagoon alone. In addition, 393 gm. dry wt./m.2 associated algae, Chaetomorpha, Fucus, and Ulva were identified. BENTHIC AND INTERTIDAL INVERTEBRATES Intertidal fauna Within the study area, Kodiak Island is best characterized for this group of organisms resulting from three reports on five separate locales (Figure 72). The most extensive study was conducted by Nybakken (1969) in Three Saints Bay. More recently, Marine Advisers (1971) reported organisms of the shallow subtidal zone near Kodiak city, which were observed or collected during a series of dives. The Fisheries Research Institute (1970) surveyed three bays occupied by canneries for both intertidal and subtidal fauna. The species identified by these various investigations are keyed to sampling location in Table 29. The Fisheries Research Institute study, though based on few samplings, found nematodes characteristic of the mean high tide level, snails and amphipods common at mean tide and barnacles, limpets, and mussels Xx NEREOCYSTIS @ ALARIA Figure 70. Location of large kelp beds in 1913 (from Rigg 1915). in the Western Gulf of Alaska REPORTS OF ZOSTERA MARINA @ McROY (1968) @ NYBAKKEN (i969) Figure 71, Location of eelgrass communities in the Western Gulf of Alaska (from McRoy 1968; Nybakken 1969). y0Z (PO? Trinity Is, Chirikof |. g Figure 72. Location of intertidal studies in the Western Gulf of Alaska (from Nybakken 1969; Fisheries Research Institute 1971; Marine Advisers 1971). TABLE 29 Intertidal and Subtidal Fauna of Kodiak Island (From Marine Advisers 1971; Fisheries Research Institute 1970; Nybakken 1969) AL AL AL PB, PB, PB, Baa TS LB AaaaS & PROTOZOA 1. Folliculinidae PROIFERA 1. Three unidentified species GOELENTERATA 1. Abietinarea sp. 2. Metridium senile 3. Unidentified anemone NEMERTINEA 1. Cerebratulus, sp. 2. Emplectonema gracile NEMATHELMINTHES 1. Unidentified species ECTOPROCTA 1. Cellaria sp. 2. Disporella sp. 3. Eucratea loricata 4. Heteropora alaskansis 5. Smittina retifrons BRACHIOPODA 1. Laques sp. 206 AL, PB, LB Al, LB, AL, LB TS TS, TS, PB, PB TABLE 29, Continued. PB TS KH TS TS TS TS TS KH KH TS TS TS TS TS TS TS TS KH TS KH LB KH TS TS TS KH TS TS TS TS MOLLUSCA BR CSCOUMPNDUNASPWNHH PRAPWUWNWNWWWNWWNWNWNnNNNNNNNNNNPRP ERR ERR NP OCOANDUABWNFOWOANDUBWNHKRFOWUOMNDUBWNHE Acmaea sp. digitalis mitra pelta A. scutum Buccinum baeri Clinocardium nuttallii Crepidula nummaria Cryptochiton stellari Entodesma saxicola Fusitriton saxicola Hiatella arctica Katharina tunicata Littorina scutulata L. sitkana Macoma balthica M. nasuta Margarites pupilla Modiolus sp. Mopalia sp. M. ciliata Mya arenaria M. truncata Mytilus edulis Nafica clausa Pododesmus_ cepio P. macroschisma Prototheca staminea pteropods PLS|S_>1> Puncturella multistriata Saxicava sp. Saxidomus giganteus Searlesia dira Solariella peramabilis Thais lamellosa T. lima Tonicella lineata Trichotropis borealis T. cancellata fenestrata fenestrata 207 Venerupis staminea unidentified dorid and eolid nudibranchs Al, AL PB PB, PB LB, PB, AL, LB, LB, AL AL LB PB, AL, LB PB PB TS KH TS TS TS KH TS TS KH TS TS TS PB KH KH KH TS KH LB TS TS TS TS PB TS TS TS TS TS PB KH TS KH KH LB TS KH TABLE 29, Continued. ANNELIDA WOANADUNAWNeR ARTHROPODA B COMNAUNFWNEH NPR RRR RR Re CWOMIDNMAWNHE Abarenicola pacifica Arctonoe pulchra Cheilonereis cyclurus Chitinopoma groenlandica Cirratulus cirratus Crucigera zygophora Echiurus echiurus Glycera nana Idanthyrus ornamentatus Nephtys caeca Nereis vexillosa N. zonata Nerine foliosa Pectinarea sp. Phyllodoce groenlandica Spirorbis sp. Spirorbis sp. S. borealis S. vitraeus Thelepus crispus unidentified polychaete Ampithec humeralis Balanus cariosus B. glandula Cancer magister C. oregonensis C. productus Chthamalus dalli Exosphaeroma oregonensis Idotea wosnesenskii Mesodotea sp. Pagettia gracilis P. productus Pagurus , sp. P. hirsutiusculus Spirontocaris brevirostris S. kincaide S. paludicola Telmessus cheiragonus unidentified caligoid copepod unidentified majiid crab 208 TS TS TS ECHINODERMATA TS 1. Cucumaria curata TS 2. Dermasterias imbricata KH 3. Evasterias sp. TS 4. E. troschelii KH 5. Henrecia sp. TS 6. H. leviuscula KH 7. Leptasterias sp. TS 8. Ophiopholis aculeata KH 9. Pisaster sp. KH 10. Pycnopodia heilanthoides KH 11. Solaster endeca TS 12. Stichopus californicus KH 13. Stronglyocentrotus drobachiensis KH 14. S. franciscanus LB 15. unidentified starfish CHORDATA - UROCHORDATA KH 1. Two unidentified species KEY KH = Kodiak TS = Three Saints Bay LB = Larsen Bay AL = Alitak PB = Port Bailey TABLE 29, Continued. 210 characteristic of mean low tide level. No physical characteristics of the beaches surveyed were mentioned to identify the substrate types encountered. Most often the presence of a cannery was indicated by generally higher nematode populations. Nybakken (1969) found barnacles characteristic of the highest tidal zones in Three Saints Bay. The vertical distribution of all organisms encountered is depicted in Figure 73. Other documented studies of this habitat are centered around Unimak Island and the tip of the Alaska Peninsula. McRoy et al. (1969) cited Cold Bay as their example for "worm and clam flats" within the study area. Scheffer (1959) noted scattered organisms from this habitat in his report (Table 30). Feder and Mueller (1972) gave a general review of the state of knowledge for each phyla in the Eastern Gulf of Alaska. TABLE 30 Intertidal and Subtidal Fauna of Unimak Island and the Alaska Peninsula (from Scheffer 1959). Organism Habitat Location Goose Barnacle, Attached to Nereocystis Otter Cove, Lepas sp. near Rhizoids Unimak Island Shipworms , Tubes in Driftwood Unimak Island Bankia setacea Clam Tideflats Alaska Peninsula Liocyma, sp. Rock Oyster, Between Tidelines Alaska Peninsula Pododesmus macrochisma 20-rayed starfish, King Cove Pycnopodia helianthoides Within this habitat, snails, limpets, and mussels may be taken for personal use. Sea cumcumbers and sea urchin offer potentials for commercial harvest. Clams are important currently in both recreational and commercial fisheries. Clams Six species of clams within the study area are taken for personal use. Razor clams, Siliqua patula, are the most important of the six and are the object of the only commercial clam fishery. The approval TIDE LEVEL IN FEET O'e- Z- | OO MTIW Ww "S LIN ol ‘MHW os MHHW o6 ool oll : wa - g o= 5° ° ° ° Balanus cariosus Balanus glandula ae Chthamalus dalli aaa Mytilus edulis Ree Katharina tunicata Li ea Acmaea pelta semaines Acmaea scutum CAS RS Acmaea mitra Peo Acmaea digitalis Tonicella lineata Eee Littorina sitkana Searlesia dira Thais lamellosa Pododesmus macroshisma SESE ER Evasterias troschelli oot ae Pycnopodia helianthoides PR Henricia leviuscula ae eee Leptasterias DR | Ophiopholis aculeata ee: [ Strongylocentrotus drobachiensis RE Pagurus hirsutiusculus SERS Bryozoans SPARS: ERS NERO BE Tunicates ODONTHALIA-LAMINARIA ZONE FUCUS ZONE BARNACLE ZONE °o _ n ol TIDE LEVEL IN METERS Figure 73. Vertical distribution of intertidal organisms in Three Saints Bay, Kodiak Island (from Nybakken 1969). 12 212 of Alaska's Shellfish Sanitation Program by the U.S. Food and Drug Administration, anticipated in early 19741, will stimulate this fishery. Razor clams are most abundant on sandy, surfswept beaches that are low in gravel and clay. They require exposure to the open ocean, and they are not found in water of low salinity or high temperature (Nanaimo Biological Station 1966a). On Unimak Island, Scheffer (1959) always found them below low tideline. The U.S. Bureau of Sport Fisheries and Wildlife (1972) reported razor clams in large numbers in some shallow waters and lagoons on Unimak Island. The Alaska Department of Fish and Game (1973) reported that Swikshak and adjacent beaches on the Alaska Peninsula have been harvested for razor clams since the early 1900s. An "Informational Leaflet" is currently in preparation on the Swikshak razor clam population by the Alaska Department of Fish and Game (Poulin and Gwartney, in press). Small amounts are also harvested from Big River Flats, Hallo Bay, and Tanner Head near Alitak. Davenport reports razor clams in San Diego Bay, north of Sand Point.2 Figure 74 indicates reported areas where these clams are abundant near Kodiak Island. Littleneck clams, Protothaca staminea, are found in both tidal and subtidal zones in protected bays and passages in association with butter clams, Saxidomus giganteus. These beaches are generally composed of a mixture of sand and gravel. The clams are found not more than a foot below the surface of the beach in the lower half of the intertidal zone (Nanaimo Biological Station 1966a). Cockles, Clinocardium nuttalii, horse clams, Schizothaerus nuttallii, and Alaskan surf clams, Spisula alaskana, are minor species which occur in habitats similar to those of butter clams, although surf clams are most often found in subtidal areas (Nosho 1972). Soft-shell clams, Mya sp., occur in quantity at Cold Bay (Kirkwood in Haynes and McCrary 1967) and throughout the region. Most clams feed on plankton and detritus which they filter from surrounding waters. Little is known about their feeding selection and preference. Life histories of clams have not been studied in detail in the Western Gulf of Alaska. Elsewhere in Alaska and British Columbia, clams reproduce by shedding eggs and sperm into the water, where fertili- zation occurs. Developing larvae are motile for 3 to 16 weeks, living in and on the sand near where they were spawned. Spawning takes place during the summer, when rising water temperatures reach 13 degrees C for razor clams or about 20 degrees C for butter clams. Larvae settle when still quite small to spend the remainder of their life cycle in bottom sediments (Nosho 1972). Figure 75 depicts the early life history and life cycle for the razor clam. Data do not exist that would allow for a more statistical approach to clam life history in this region. Kenneth L. Torgerson, Seafood Sanitation Coordinator, Alaska Dept. of Health and Social Services, Juneau. Personal communication. Dec. 18, 1973. 2G1enn Davenport, Area Management Biologist, Alaska Department of Fish and Game, Cold Bay. Personal communication. & RAZOR AND/OR BUTTER CLAMS Figure 74, Location of significant razor and butter clam beaches in the Kodiak-Shelikof Area (from Fay 1972). £12 EARLY LIFE HISTORY "SETTING" FREE- SWIMMING LARVAE SPAWNING J ! FEB. MAR. APR. MAY JUN. JUL. AUG. JUVENILE IN SAND FREE-SWIMMING LARVAE _L | | 3 4 5 6 YEARS OF AGE Figure 75. Early life history and life cycle of the razor clam, Siliqua patula (from Nanaimo Biological Station 1966a, Nosho 1972). a Razor clams spawn for the first time at the end of their third year, when they are about 8.5 cm. in length. Butter clams spawn at four years, when they are about 5 cm. Littleneck clams spawn first at two or three years when slightly more than 2.5 cm. long. Clams may live for a maximum of 15 to 20 years (Nanaimo Biological Station 1966a). Nosho (1972) has summarized the knowledge for cockles, razor, and butter clams along the Eastern Gulf of Alaska coast. Benthic fauna Soviet investigations of benthic fauna in the Gulf of Alaska have been more extensive than investigations conducted by the United States. Semenov (1965) calculated an average benthic invertebrate biomass for the continental shelf in the Western Gulf of Alaska at 180 gm. wet wt./m.2 from bottom grab samples which were preserved in formalin and weighed in the laboratory at the completion of the cruises. The continental slope averaged 19 gm. wet wt./m.?. High concentrations of benthic organism were found in Unimak Pass, south of Sanak Island, in the vicinity of Trinity Island, on Albatross and Portlock Banks, and west of Kodiak Island (Figure 76). Benthic invertebrates were divided for analysis into four trophic groups representing different feeding types (Table 31). Figure 77 illustrates the distribution of the dominant trophic groups. Sessile (nonmobile) filter feeders were dominant at moderate depths (44-92 m.) and attained higher biomass than any other group (81-988 gm./m.2). These organisms were most abundant along the shelf margin, between submarine canyons, and on banks, such as southwest of Chirikof and Sanak Islands. This was attributed to stronger currents in these areas which prohibited sediments from accumulating. Rocky or gravel substrates provided many excellent points for attachment while currents yielded a continuous supply of food. Between 52 and 158 m., both mobile filter feeders and browsers were common, though separated according to sediment composition. On coarser sediments, mobile filter feeders reached a biomass of 15- 209 gm./mm.“. On finer sediments, browsers predominated with a biomass of 439 gm./mm.?. These two groups were encountered most regularly in the Trinity-Chirikof Island vicinity. Lowest on the shelf, from 100 to 244 m., were the nonselective consumers with a biomass of 15-112 gm./m.2. This group was characteristic of the entrance to Shelikof Strait, west of Kodiak Island. Varied bottom topography and sediment character resulted in an irregular distribution of trophic groups. For example, Albatross Bank had a fairly regular relief, and sessile filter feeders predominated. On Portlock Bank, depressions retaining sediment were common, and mobile filter feeders attained a higher biomass than sessile forms. nN w =] MORE THAN 500 GM/m2 (11) 100-500 6m/m2 =] 10-100 GM/M2 LESS THAN 10 GM/M2 Figure 76, Benthic fauna biomass in the Western Gulf of Alaska (from Shevtsov 1964, Semenov 1965). 912 217 TABLE 31 List of Major Species of Benthic Fauna in The Gulf of Alaska Shallows (from Semenov 1965; Shevtsov 1964) KEY TO SYMBOLS USED IN LIST: Affliation to trophic group: S-nonmobile filter feeders; M-mobile filter feeders; B-browsing detritus eaters; N-nonselective detritus eaters OCTOCORALLIA Family Pennatulidae Leioptilum gurneyi Ss LAMELLIBRANCHIATA Family Nuculidae Nucula tenius N. charlottensis N. mirabilis Acila castrensis BDanww Family Ledidae Leda fossa pernula -» conceptionis + minuta Yoldia myalis Y. scissurata Y. sanesia Y. tracieformis Portlandia japonica (ete ie WDaBmtnnwunwnw Family Arcidae Limopsis aquitanica M Family Mytilidae Dacrydium vitreum Modiolus modiolus S TABLE 31, Continued. Musculua discors M. seminudus Crenella columbiana Family Pectinidae Chlamys beringlianus Pecten alaskense Family Anomiidae Pododesmus macrochisma Family Limidae Lima attenuata Family Astartidae Astarte multicostata .» alascensis foani bennettii + Montaqui var. warhami Rictocyma esquimalti R. zenkevitchi > I> I> I> Family Carditidae Venericardia ventricosa V. crebricostata V. stearnsii Family Cardiidae Serripes groenlandicus Cardium funcanum Cc. ciliatum Family Veneridae Liocyma fluctuosa Family Mactridae Spisula alascana Family Tellinidae Tellinula salmonea Macoma calcarea M. incongrua n BRR REE = ZERE ZRERE aaow 218 TABLE 31, Continued. Family Saxicavidae Saxicava arctica Family Myacidae Mya intermedia Family Pandoridae Pandora bilirata Family Cuspidariidae Cuspidaria beringensis POLYCHAETA Family Phyllodocidae Phyllodoce groenlandica Family Glyceridae Glycera capitata G. tesselata Goniada annulata Glycinde armigera Family Nephthydidae Nephthys ciliata Family Eunicidae Buince kobiensis Onuphia conchylega QO. iridescens O. parva Lumbriconereis bifurcata Family Spioidae Laonice cirrata Family Magelonidae Magelona pacifica Family Cirratulidae Cirratulus cirratulus Chaetozone setosa Family Scalibregmidae Scalibregma inflatum 219 TABLE 31, Continued. Family Maldanidae Praxilella gracilis Axiothella catenata Asychis disparidentata A. similis Maldane sarsi Family Sabellariidae Idanthyrsus armatus Family Sternaspididae Sternaspis scutata Family Ampharetidae Melinna cristata M. elisabethae M. ochotica Lisippe labiata Amphicteis scafobranchiata Family Trichobranchidae Terebellides stroemi Family Terebellidae Artacama proboscidea Pista cristata P. vinogradovi Family Sabellidae Chone cincta Myxicola infundibulum Family Serpullidae Crucigera irregularis Serpula zygophora Spirorbis sp. SIPUNCULIDA Family Sipunculidae Golfingia eremits G. margaritacea G. schuttei G. vulgaris Phascolion strombi 222224 Daw ww wom nn nn 2222a22Z 220 TABLE 31, Continued. BRACHIOPODA Family Terebratellidae Terebratulina californicus T. unguicola Family Rhynochonellidae Frieleia halli CRUSTACEA Order Amphipoda Family Lysianassidae Anonyx nugax Family Ampeliscidae Ampelisca plumosa A. eoa A. macrocephala Byblis gaimardi Family Phoxocephalidae Pontarpinia longirostris Family Gammaridae Maera prionochira Melita dentata Family Taronidae Surthoe crenulata Order Cirripedia Family Balanidae Balanus balanus B. crenatus . hesperias rostratus Io |o9 | Order Decapoda Family Axiidae Calastacus investigatoris n i << ) ANNnNN 221 TABLE 31, Continued. ASTEROIDEA Family Porcellanasteridae Ctenodiscus crispatus Family Echinasteridae Henricia spiculifera OPHIUROIDEA Family Ophiacanthidae Ophiophthalmus cataleimnoides O. normani Family Ophiactidae Ophiopholis aculeata 0. pilosa 0. mirabilis Family Amphiuridae Amphioplus macraspis A. craterodmeta A. perirecta sundevalli carchara + psilopora . pugetana > I> I> I> Family Ophiolepididae Amphiophiura ponderosa Ophiura criptolepis O. sarsi O. leptoctenia QO. maculata OQ. tetracantha oO. quadrispina ECHINOIDEA Family Schtellidae Echinarchnius parma Family Schisasteridae Brisaster latifrons B. Townsendi ww Daw RPwWwmWnmnnny DB wWBnwnnne7 22 222 NONMOBILE FILTER FEEDERS MOBILE FILTER FEEDERS BROWSING DETRITUS EATERS IT] NONSELECTIVE DETRITUS CONSUMERS Figure 77. Dominance of various feeding types in benthic fauna in the Western Gulf of Alaska (from Shevtsov 1964, Semenov 1964). £22 Benthic invertebrate biomass was greater in the study area than for the Eastern Gulf of Alaska, possibly due to stronger currents and less glacial siltation in the Western Gulf (Semenov 1965). A high percentage of this biomass was estimated to be available for ‘ fish food in the Gulf of Alaska compared to other parts of the North Pacific (Moiseev 1964). The most extensive American investigation which recorded benthic fauna has been the exploratory fishing drag program of the National Marine Fisheries (undated). Caution must be exercised in interpreting data from such trawl studies. Different trawl surveys used different gear, altering the susceptibility of various groups to capture. The National Marine Fisheries Service surveys did not trawl in a regular sampling pattern, thus effort is not equal throughout the study area (Figure 78). Surveys in the Western Gulf were limited to summer only--979 of 1,296 trawls were taken between June 1 and August 31 and no trawls were recorded from late October through early April. Fifty-four percent of these stations were surveyed with shrimp trawls and 35 percent with scallop dredges. The remainder used various other gear. Thus, much of the catch may have been incidental to the target species sought. Data indicate locations where concentrations of certain organisms have been noted during the warmer months of the year. Absence of data should not be interpreted as indicative of the absence of the organisms and may result from bias in the sampling program--either in gear, season, or sampling effort. Certainly other areas of concentra- tion exist which have not been recorded in the limited sampling conducted in this area. Within the study area 20 major benthic invertebrate types were reported (Table 32). Of these 10 were more commonly encountered or yielded high catches per hour trawled. Large catches per hour trawled for these 10 groups were recorded at locations shown in Figure 79. Large quantities of mussels, basketstars, and sea pens were most often encountered west of Chirikof Island. Large catches of sea cucumbers and sea urchins were frequently recorded on Portlock Bank and in the vicinity of the Barren Islands. Abundant sea anemones and starfish were reported from scattered locations. Hitz and Rathjen (1965) recorded benthic invertebrates east of Kodiak and reported that half the invertebrate biomass obtained in the survey drags was composed of heart urchins and that 20 percent was starfish. The remaining invertebrates were commercial species and will be discussed individually in following sections. Barysheva (1965) reported 14 species of Cumacean crustaceans occurring in the Gulf of Alaska, but did not identify sampling locations. The Faculty of Fisheries, Hokkaido Univ. (1968) has made only one series of trawls near Seward Gully, which yielded little invertebrate information. Marine Advisers (1971), diving at depths of between 25 and 45 m. near Kodiak, reported many common intertidal species (Table 29) plus benthic species, Pecten caurinus, and Neptunea lyrata. 224 1-14 TRAWLS IS-39 TRAWLS 40-69 TRAWLS OVER -70 TRAWLS Figure Distribution of Naticnel Marine bisherie: Service trawl ¢ rt in the Western Gulf of Aloska ffror bur B). Gc Major Benthic Invertebrate Groups reported from 1,296 National Marine Fisheries Service Exploratory Fishing Drags in the Western Gulf of Alaska (from National Marine Fisheries Service, undated) Group Sea Cucumbers Starfish Sea Urchins Sea Anemone Basketstars Sea Pens Mussels Brittlestars Crabs Hermit Crabs Barnacles Sponge Whelks Sand Dollars Clams Horse Crab Sea Fan Octopus Box Crab Worms TABLE 32 Occurrence in Drags common common common common common common occas. occas. occas. occas. occas. seldom seldom seldom rare rare rare rare rare rare Maximum Catch (kg./hr.) 1,360 815 755 180 180 90 725 300 25 30 35 225 15 225 90 Trace Trace, Trace Trace Trace 226 SEA URCHINS MUSSELS SEA ANEMONES BASKET STARS SPONGES Figure 79a. Location of large trawl catches of benthic fauna reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). L0Z X BRITTLE STARS @ SEA CUCUMBERS @ STARFISH @ SEA PENS DW SAND DOLLARS Figure 79b. Location of large trawl catches of benthic fauna reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated), 822 229 Scheffer (1959) conducted little benthic work, but does report Mytilus californicus in 60 m. of water near Sanak Island. Eyerdam's (1960) list of mollusk and brachiopod species of Afognak and Sitkalidak Islands is comprehensive (Table 33). King Crab King crab rank with salmon as one of the most valuable commercial species harvested from the Western Gulf waters, with peak harvests exceeding 50,000 metric tons in 1966. Vigorous commercial fisheries have existed in the study area for more than 20 years (Buck 1973). These fisheries concentrate on the continental shelf south and east of Kodiak Island and west of the Shumagin Islands. Two species contribute to the commercial catch. Paralithodes camtschatica provides almost the entire harvest; small quantities of P. platypus have been recorded at Kodiak (Gray et al. 1965). Exploratory fishing drags of the National Marine Fisheries Service (undated) provide limited information on king crab distribution within the Western Gulf. In late summer large quantities of these crabs were found south of Unimak Island, from Balboa to Pavlof Bays north and west of Unga Island, and widely scattered to the south and east of Kodiak (Figure 80). Crabs were caught in quantity from 36 to 200 m., although crabs have been reported from depths to 350 m. (Eldridge 1972a) and in the immediate sub-tidal zone for spawning (Gray and Powell 1966). Most crabs appeared concentrated between 50 and 170 m. in late summer. The maximum catch recorded was 695 kg./hr. Trawls in the Eastern Gulf indicate a much lower abundance of this species there (Hitz and Rathjen 1965). Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The International Pacific Halibut Commission (1964) reported catches of king crabs incidental to a halibut survey conducted during 1961 to 1963 on a regular sampling pattern (Figure 81). Catches of king crabs in excess of 200 individuals per hour trawled are indicated in Figure 82. King crabs were taken in quantity throughout the region and with greatest frequency northeast and southwest of Kodiak Island. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The National Marine Fisheries Service, Northwest Fisheries Center, Seattle, is currently completing a series of maps based upon trawl catches taken during this survey. These maps will be available in early summer of 1974. Adult king crabs move to shallows of less than 75 m. to breed in the spring and return to deeper waters in the summer and early autumn (Powell and Reynolds 1965). Hayes and Montgomery (1963) found that more than 90 percent of the crab tagged for study were recaptured within 56 km. of their release. This indicates no major movement by individual crabs. Immature crabs remain in inshore shallows separate from adults. Adult crabs may school by size, sex, or condition of carapace, except during the mating season (Eldridge 1972a). TABLE 33 230 Mollusca collected from Afognak and Sitkalidak Islands (from Eyerdam 1960). PELECYPODA Astarte alaskensis A. arctica A. esquimalti A. rollandi Bankia setacea Campsomyax kennerlyi Clinocardium californiense C. ciliatum C. fucanum C. nuttallii Cuspidaria beringensis Entodesma saxicola Kellia laperousei K._suborbicularis Leda minuta Limatula subauriculata Lyocyma viridis Lyonsia pugetensis L. striata Macoma alaskana balthica brota incongrua inflatula inquinata middendorffii nasuta sitkana yoldiformis odiolaria laevigata nigra substriata M. vernicosa Modiolus modiolus Mya intermedia M. japonica M. truncata M. truncata var. uddevallensis §lSiSIS15/512151215 =IzI= Mytilus californianus M. edulis Nucula (Acila) castrensis N. tenuis N. tenuis expansa Pandora (Kennerlia) bilirata P. (K.) filosa Pecten alaskensis P. caurinus P. (Chlamys) hindsii navarchus P. islandicus beringianus Phacoides annulata P. tenuisculpta Pododesmus (Monia) macrochisma Protocardia centifilosa Protothaca staminea P, staminea orbella Rochefortia aleutica R. planata R. tumida Saxicava arctica S. pholadis Saxidomus gigantea Schizothaerus capax Serripes groenlandicum S. laperousii Siliqua patula S. patula alta Spisula alaskana Tellina lutea T. lutea venulosa T. salmonea Thyasira flexuosa Venericardia alaskana V. ventricosa Yoldia ensifera Y. limatula Y. scissurata SCAPHOPODA Dentalium dalli OPISTHOBRANCHIA Acteocina eximia Cylichnella alba C. attonsa C. nucleola C. occulta Haminoea olgae H. vesicula NUD IBRANCHIA Anisodoris nobilis Melibe leonina PTEROPODA Spiratella pacifica PULMONATA Arctonchis borealis TABLE 33, Continued. PROSOBRANCHIA Admete couthouyi A. couthouyi gracilior Aforia circinata Bel a alaskensis [DO] WD] DW[|W|D|D|D| am w Beringius crebricostatus B. B. chiachiana excurvata fidicula inequita nobilis pleurotomaria rosea scalaris sculpturata solida turricula eyerdami kennicotti Chrysodomus lirata C. pribiloffensis Cc. Col satura us Olivella boetica Searlesia dira Sprioglyphis lituellus Siphonaria (Liriola) thersites (Latisipho) jordani 231 @ 90-270 KG/HR. Xx MORE THAN 270 KG/HR. Figure 80, Location of large trawl catches of king crab reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). ZES 233 ° ee £ 00000 I> 0 0 COg~O Se 200000 0 0008000000000000 9000000000 cog poood. Z * © @B!0 0 0'00 000 © 0% = Bip 00000000000 o b $s g ° -— n a “4 & & OQ oO » 2 Q om OS® 000 000000 0 0 0 02001 ‘ ©0200 0 0000 0b00 00 00000 00000 #000 00000 6 Gece 200000 000000000000 So g 00 00 0000000 0 30000 0dd8op ol © 000b098000 bo 22 BK xX + b@ 0 00Q00: © 000 s, ° e@poodo [SOS o000 Po OM OO) g0%¢ OBB odo %s 4, CRY % pt 000 000 go QO 0000000 gO 20 0000005 Distribution of trawl stations repetitively sampled by the International Pacific Halibut Commission during 1961 to 1963 (from International Pacific Hal TRAWL STATION Figure 81. WP NON-TRAWLABLE AREA @ TRAWL YIELD EXCEEDING 200 INDIVIDUAL CRABS/HR. Figure 82+ Location of large trawl catches of king crab reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964) - bez In the Kodiak area, Powell and Reynolds (1965) identified six distinct stocks which appear to maintain their separation (Figure 83). Gray and Powell (1966) reported that king crabs mature sexually at five to seven years when carapace length is approximately 100 mn. Young females and older males reach the spawning grounds first and begin breeding as early as mid-March. Older females and young males may continue the breeding into late May. The Kodiak vicinity alone is reported to have 19,120 sq. km. of potential breeding area, of which 13,028 sp. km. of area are more than 48 km. offshore (McMullen 1967a). Male king crabs are polygamous and, even when newly matured, appear to breed successfully with five to seven females. The king crab fishery harvests males only at a minimum carapace width of 17.8 cm. This allows males one or two breeding seasons after maturity and before exposure to commercial harvest. In probably an extreme example, Kingsbury and James (1971) reported 93 percent of the adult males on the breeding grounds at Alitak in 1970 were of sublegal size. The ratio of males to females on breeding grounds is an important factor in reproductive success and may be influenced by fishing intensity. McMullen (1967c) reported a sex ratio of 11 females per male on the Marmot Flats breeding ground in 1967. Yoshihara in Haynes and Lehman (1969) reported nine males with 700 females on the Kaguyak spawning area in 1968. Powell and Gray (1964) reported that the commercial catch in some years apparently exceeded the recruitment of newly matured males into the breeding population. Thus the sex ratio of mature females to mature males increased and a greater proportion of the catch became "recruits" or crabs exposed to their first year of commercial harvest. Some areas have seen harvests composed of 80 percent recruits (Alaska Dept. of Fish and Game 1973b). West of Kodiak, along the Alaska Peninsula, harvests have taken greater than 50 percent recruits (McMullen and Yoshihara 1970). King crabs seem to prefer kelp covered reefs or rocky areas for spawning (Powell and Nickerson 1965). Within two hours after the female molts, ovulation and fertilization is accomplished. Mated females leave the spawning area, while males may remain for more than one month to continue breeding (Powell in Haynes and Lehman 1969). Haynes (Haynes and Lehman 1969) indicated increased fecundity with increased size; the largest females produce up to 400,000 eggs (Figure 84). After being carried externally for about 11 months by the female, eggs hatch into zoea larvae. The zoea larvae are planktonic and feed upon diatoms. After approximately 60 days the larvae molt to glaucothoe and become benthic in habit for the remainder of their life cycle. From investigations in the Bering Sea, king crab feed on a wide variety of benthos (McLaughlin and Hebard 1959). 235 Figure 83. Preliminary boundaries of king crab stocks in the Kodiak Island vicinity which appear to maintain partial separation (from Jackson and Manthey 1969). 236 Y = EGGS (THOUSANDS) 400 350 300 250 200 150 100 50 9:0 100 Figure 84. Ilo 120 130 140 150 160 170 Iso X= CARAPACE LENGTH OF CRAB (MM.) Relation of number of eggs to carapace length of female king crabs (from Haynes and Lehman 1969). 237 238 The variable survival rate among juvenile crabs results in great variability in the numbers of crabs of different year classes which mature and are recruited into the commercial fishery. Upon reaching maturity, females molt once a year prior to breeding. With each molt, approximately six mm. in carapace length is gained. Males molt once a year in their sixth, seventh, and eighth years, but in later years molt biennially or (rarely) triennially (Jackson and Manthey 1969). Powell (Haynes and Lehman 1969) believed males who skip molting two consecutive years may die after their next mating. Males may add up to 20 mm. in length to their carapace with each molt. Males grow significantly larger than females (Powell and Nickerson 1965) and may reach maximum ages exceeding 15 years although exact aging is impossible (Eldridge 1972a). Due to the heavy commercial fishery, older age classes now are rarely encountered. Figure 85 depicts the early life history and life cycle of the king crab. The 1964 earthquake and accompanying tidal wave did not greatly disrupt the crab population in the Kodiak vicinity (Powell and Nickerson 1965). Tanner Crab Tanner crabs are the basis for one of Alaska's newest fisheries. The Western Gulf has produced the bulk of this species, with more than 4,000 metric tons landed in 1969 (Buck 1973). Areas fished for this species are similar to those harvested for king crabs. Although 3 species of Chionoecetes are found in this area, only C. bairdi is presently harvested in the Western Gulf (Brown and Powell 1972). C. angulatus is common on the Gulf abyssal plain down to 2,050 m. (Brown 1971). C. opilo is most abundant north and west of the study area. Further discussion will be confined to C. bairdi. Exploratory fishing drags of the National Marine Fisheries Service (undated) provide a general picture of tanner crab distribution and abundance throughout the study area during summer and early autumn. Tanner crabs were taken in quantity near the eastern end of Unimak Island, between Unga Island and Pavlof Bay; Alitak Bay; Marmot-Chiniak Bays, and in the Cape Douglas vicinity (Figure 86). Abundance and distribution may vary considerably with the season due to vertical movements which are inadequately understood. Crabs were caught in quantity by the National Marine Fisheries Service between 38 and 244 m., though they were reported as deep as 520 m. (Brown 1971) and enter much shallower waters for spawning (Brown and Powell 1972). Crabs appeared most concentrated between 50 and 130 m. during late summer and early autumn. The maximum trawl yielded 1,512 kg./ hr. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. EARLY LIFE HISTORY PREVIOUS EGGS OF PREVIOUS -EMALES MOLT, BREEDING YEAR HATCH, MALES MOLT EMALES. CARRYING. DEVELOPING. EGGS SEMI-PELAGIC LARVAE L ! ! | ! ! | J JAN. FEB. MAR. APR. MAY. JUN. JUL. AUG. SEP OCT. NOV. DEC. MALES OF COMMERCIAL SIZE ADULT FEMALES MOLT & BREEDING | | | | | | LIFE ADULT MALES MOLT | | | | | CYCLE l | ! 1 ! I | _L 1 ° \ 2 3 4 5 6 7 8 9 YEARS OF AGE Figure 85. Early life history and life cycle of king crab, Paralithodes camtschatica (from Powell and Nickersor 1965, Powel! and Reynold: 1965, Gray and Powel?! 1966, Haynes and Lehman 1969, Jackson and Manthey 1969). @ 90-270 KG/HR. x MORE THAN 270 KG/HR. Figure 86. Location of large trawl catches of tanner crab reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 0r2 241 The International Pacific Halibut Commission (1964) reported catches of tanner crabs in excess of 200 individuals per hour trawled at the station locations indicated in Figure 87. Tanner crabs were distributed widely throughout the entire continental shelf of the Western Gulf of Alaska. Caution similar to that expressed previously for benthic fauna, should be obwerved in the interpretation of inci- dental trawl catches. Apparently, tanner crabs compose a high proportion of the benthic invertebrates east of Kodiak Island. Hitz and Rathjen (1965) found that 22 percent of their invertebrate catch was tanner crab in the Eastern Gulf of Alaska. Heart urchins were the only invertebrate encountered more often. Female tanner crabs mature sexually when they reach a carapace width of 70 to 100 mm. and males when they reach a width of 90 to 140 mm. Breeding commences in shallow areas in early January and may continue into mid-May (Brown and Powell 1972). Lehman (Haynes and Lehman 1969) found unmolted females with new egg clutches. Molting in females ceases upon maturity and is not essential to successful breeding. Little is known of the life history of C. bairdi within the Western Gulf of Alaska. Developing eggs are carried by female tanner crabs for about 11 months. Females carry from 5,000 to 140,000 eggs; 30,000 to 80,000 eggs are considered average. Upon hatching, tanner crab larvae spend time in a planktonic existence before settling to the bottom for the remainder of their life cycle (Eldridge 1972b). The early life history and life cycle for C. bairdi must be considered tentative, as determinative studies are lacking (Figure 88). Maximum size of tanner crabs differs between sexes. Males continue to molt throughout their life and may exceed 200 mm. carapace width. Females cease molting soon after they molt to maturity and may reach a carapace width of no more than 125 mm. (Eldridge 1972b). Catches of tanner crabs are continuing to increase each year and no pattern to this fishery has been established. Currently, no commercial size limit is imposed by the Alaska Department of Fish and Game in a "males only" fishery, although processors may restrict landings to some minimum size, now about 125 mm. This practice may allow males at least one breeding season before exposure to the fishery. Eldridge (1972b) reviewed the tanner crab. Parts of his information, derived from studies of C. opilio, must be used with reservation when applied to C. bairdi. Dungeness Crab The Dungeness crab, Cancer magister, supports a major inshore commercial fishery in the Kodiak area with catches exceeding 3,000 metric tons in the late 1960s. In the remainder of the study area, this fishery has been irregular with much smaller harvests (Alaska Department of Fish and Game 1972). 7 @ TRAWL YIELD EXCEEDING 200 INDIVIDUAL CRABS/HR. Figure 87, Location of large trawl catches of tanner crab reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). coz EARLY LIFE HISTOR y FEMALE MOLTS, MALE MOLTS (UNKNOWN) EGGS OF PREVIOUS YEAR HATCH, BREEDING SEMI-PELAGIC LARVAE l L ! 1 | JUL. AUG. SEP. OcT. NOV. DEC. MALE MOLTS, FEMALE MOLTS (UNKNOWN) LIFE MALES OF COMMERCIAL SIZE (UNKNOWN) CYCLE SEXUALLY MATURE ADULTS BEN TEC. JUVENICES SEMI-PELAGIC ZOEA L | UREEERSREAERE GEBE 1 —L 1 Js 1 | SRAIAESAROERRDS: 2008 it Oo | 2 3 4 5 6 7 8 9 10 YEARS OF AGE Figure 88. Early life and life cycle of tanner « ionocecete {from Haynes and Lehman 1969, Brown and Powe?! , Eldridge !¢ LD ———____] oot 244 Exploratory fishing drags (undated) of the National Marine Fisheries Service indicated a scattered distribution of this species in the Western Gulf. Few large catches were recorded during the summer and were located south of the Trinity Islands, in Beaver Bay, and along the southern coast of Unimak Island (Figure 89). Crabs were caught in quantity between 46 and 96 m., though they may be concentrated between tideline and 50 m. during spawning earlier in the spring, or as deep as 200 m. during the remainder of the year (Nanaimo Biological Station, undated). Large catches of crabs were encountered most often between 62 and 88 m. The maximum trawl produced 94 kg./hr. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The International Pacific Halibut Commission (1964) reported catches of Dungeness crabs in excess of 200 individuals per hour trawled at station locations indicated in Figure 90. Dungeness crabs were found in quantity in the same general locations as were reported in the National Marine Fisheries Service surveys. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. These crabs move offshore during the winter and return to shallow waters in early spring and summer (Mayer 1972). Generally, these crabs prefer a firm, sandy bottom (Nanaimo Biological Station, undated). Dungeness crabs appear regularly in trawls east of Kodiak Island. Hitz and Rathjen (1965) reported that Dungeness composed 3.5 percent of the benthic invertebrate catch. This was the second highest catch of commercially important invertebrates, exceeding only tanner crab. Male Dungeness crabs with a carapace width greater than 140 mm. are mature, while females mature upon reaching 100 mm. Time of mating in Gulf waters has not been determined, though summer is reported as the breeding season in British Columbia. Eggs are not spawned until late fall or early winter (Nanaimo Biological Station, undated). As many as 1.5 million eggs are carried on the abdomen of the female and hatch in the spring. Larvae then spend as long as 3 months in a planktonic form before settling to the bottom for the remainder of their life cycle (Nanaimo Biological Station, undated). Both sexes of Dungeness crab mature in three years. The male attains a larger maximum size than the female and both may live from eight to ten years. Molting may occur annually in mature adults. Large males may exceed 200 mm. carapace width, while females seldom exceed 150 mm. (Mayer 1972). A commercial size limit of 17.8 cm. width, in the Kodiak and Chignik Districts would appear to allow males a minimum of two breeding seasons prior to exposure to the fishery. Early life history and life cycle are presented in Figure 91, but must be considered tentative, since much of the present knowledge of Dungeness crabs has been collected farther south. Current investigations by the Alaska Department of Fish and Game at Sharatin Bay on Kodiak Island are expected to greatly increase the understanding of Dungeness crab in Gulf of Alaska waters (Alaska Dept. of Fish and Game 1973b). xX MORE THAN 45 KG/HR. Figure 89. Location of large trawl catches of Dungeness crab reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). Sz @ TRAWL YIELD EXCEEDING 200 INDIVIDUAL CRABS/HR. Figure 90. Location of large trawl catches of Dungeness crab reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). 9672 EARLY LIFE F PREVIOU HISTORY EGGS OF PREVIOUS FEMALES MOLT, BREEDING YEAR HATCH, MALES MOLT, (UNKNOWN) (LESH CARRYING DEVELOPING SEMI-PELAGIC LARVAE l \ L ! 1 ! 1 i i | 1 1 | JAN. FEB. MAR. APR. MAY JUN. JUL. AUG. SEP. OCT. NOV. DEC. MALES OF COMMERCIAL SIZE ADULT FEMALE MOLTS | | | | | | | LIFE ADULT MALE MOLT (UNKNOWN) CYCLE BENTHIC JUVENILES SEMI-PELAGIC ZOEA l | 1 1 | | 1 i 1 1 ° I 2 3 4 5 6 7 8 9 10 YEARS OF AGE tgure 91. Early life history and life cycle of Dungeness crab, Cancer magister (from MacKay 1942, Maver 1972). Lou 248 Dungeness crab feed on benthic fauna; stomach analyses show a preponderance of clams and various crustaceans (Mayer 1972). Shrimp A large volume of the shrimp harvest on the continental shelf of the Western Gulf of Alaska has been developed by Japan, the USSR and the United States within the past decade--with more than 40,000 metric tons harvested in recent years. Four species occur in commercial quantity: Pandalus borealis (pink); P. hypsinotus (coonstripe); P. goniurus (humpy); and P. dispar (sidestrip). Of these four, P. borealis comprises 97 percent of the catch landed in Kodiak (Olsen in Haynes and Lehman 1969). Major fishing areas are east and south of Kodiak Island and east of the Shumagin Islands. Kodiak clearly dominates the West Coast shrimp harvest today (Alaska Department of Fish and Game 1973b). Shrimp species move off the ocean bottom at night, each species differs in the proportion of individuals which migrate upward and the distance upward traveled. Different species can be found all the way from the surface to at least 466 m. (U.S. Bureau of Commercial Fisheries 1965). In the Western Gulf, large concentrations are found over sand, silt, or mud subtrates; exploration conducted in more rocky and more difficult trawling areas has been too limited to truly assess the potential of those areas. Exploratory fishing drags of the National Marine Fisheries Service (undated) have identified areas of shrimp concentration in the Western Gulf for the four commercial species as well as reporting small quantities of Danae, Hippolytid, Spriontocaris, and Cragon shrimp. P. goniurus and P. hypsinotus are encountered at depths between 40 and 200 m. with most concentrations from 60 to 130 m. Large hauls were encountered more regularly in late summer at these depths. Large quantities of P. goniurus and P. hypsinotus were found in Alitak and Uganik Bays, with scattered showings throughout the rest of the region (Figures 92 and 93). Largest hauls were 2,000 kg./hr. for P. goniurus and 350 kg./hr. for P. hypsinotus. Pandalopsis dispar was broadly distributed from 88 to 258 m. but was concentrated between 110 and 210 m. Large hauls were encounted throughout the summer for this species. Marmot Bay, waters southeast of Cape Douglas, and the Shumagin Islands vicinity held large quantities, with many scattered large trawls thoughout the area (Figure 94). The maximum trawl for this species yielded over 2,050 kg./hr. @ 90-270 KG/HR. x MORE THAN 270 KG/HR. Figure 92, Location of large trawl catches of humpy shrimp reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 602 @ 90-270 KG/HR. x MORE THAN 270 KG/HR. Figure 93, Location of large trawl catches of coonstripe shrimp reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 0sz @ 90-270 KG/HR. ad x MORE THAN 270 KG/HR. Location of large trawl catches of sidestripe shrimp reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). [Sz 252 P. borealis is the most abundant shrimp species in the Western Gulf. Inhabiting moderate depths from 40 to 232 m., this species appeared most concentrated between 110 and 170 m. Large hauls were encountered with increasing frequency throughout the summer into early autumn. Almost any large bay along the north and southeast coasts of Kodiak and Afognak, along with Stepovak, Balboa, and Pavlof Bays were spectacular producers. Widely scattered, large hauls were made throughout the area (Figure 95). The largest trawl produced over 5,500 kg./hr. In addition to U.S. exploration, the USSR has identified (Ivanov 1969) producing areas which lie farther offshore (Figure 96). These yield P. borealis primarily. Japanese exploration has been documented best by Butler (1967). Barr and McBride (1967) found that P. borealis made a diurnal movement off the bottom at dusk and returned to the bottom in early morning (Figure 97). Barr found that peak feeding occurred from 2100 to 2400 hours (Haynes and Lehman 1969). Vertical separation may be maintained between species; Ronholt reported that bottom trawls caught 67 percent P. borealis when fishing on the bottom, but yielded 81 percent P. goniurus when fishing off the bottom (Haynes and Lehman 1969). Seasonal movements also may be important. Pederson reported that fishermen in the Kodiak area land a much higher proportion of Pandalopsis dispar from February through May than the remainder of the year (Haynes and Lehman 1969). McCrary concluded from catch analysis that gravid females and older shrimp move to deeper waters (Haynes and Lehman 1969). Ivanov (1964) found shrimp tended to concentrate where warmer waters of the Alaska current overran the continental shelf, causing sharp temperature gradients. In particular, shrimp avoided waters warmer than 8 degrees C and tended to accumulate at 3.5 to 4.2 degrees C. Such conditions regularly occur east of the Shumagin Islands where Soviet shrimpers have made large harvests (Figure 98). All four species of shrimp have quite similar life histories and will be discussed together. Spawning normally occurs in August and September, with Pandalopsis dispar preceding P. borealis (Jackson in Haynes and Lehman 1969). From 900 to 3,000 developing eggs are carried by the female on her abdomen. Larger, older females normally carry the greater number of eggs (McBride in Haynes and Lehman 1969). P. borealis larvae hatch from February through April or early May, and Pandalopsis dispar hatch slightly later, from April into mid-July (Jackson in Haynes and Lehman 1969). Ivanov (1969) observed that the use of bays and island regions by spawning shrimp afford the benefits of unique circulation patterns, which prevent larvae from drifting into unfavorable areas. Larvea are free-swimming for approximately two and one-half months when they settle to the bottom to assume adult behavior. These juveniles are most abundant in waters deeper than 40 m. However, at the onset of winter, they appear to migrate to shallower waters of less than 40 m. (McCrary in Haynes and Lehman 1969). X MORE THAN 270 KG/HR. Figure 95. Location of large trawl catches of pink shrimp reported by the National Marine Fisheries Service ‘n the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). €SZ 165° 160° 155° 150° 145° 140° 135° 130° ALASKA to CANADA 60° 160° BRISTOL BAY 55° 50° 50° AREAS OF INSHORE CONCENTRATIONS AVERAGE CATCH KG/HR OF INSHORE AREAS AREAS OF OFFSHORE CONCENTRATIONS AVERAGE CATCH KG/HR OF OFFSHORE AREAS 165° 160° 155° 150° 145° 140° 135° 7130° Figure 96. Location of Soviet offshore shrimp grounds, Alaskan inshore shrimp grounds and comparative catches in Gulf of Alaska (from Ivanov 1969). 4st POT DEPTH (m.) 0.6 229 45.7 68.6 |- BAR WIDTH INDICATES NUMBER CAUGHT al 50 eS; 100 [ GRE 2.00 1200 1500 Figure 97. 1500 1800 2100 2400 0300 0600 03900 1800 2100 2400 0300 0600 0900 1200 TIME PERIODS Catches of pink shrimp for 3-hour fishing periods through- out a 24-hour period in pots of a surface-to-bottom set (from Barr and McBride 1967). Sst XX PR BOREALIS GROUNDS |—~----BOTTOM TEMPERATURE (°C) ——— 200 M. CONTOUR Figure 98. Bottom temperature isotherms in the Western Gulf of Alaska (from Ivanov 1964). 9S2 257 Shrimp have a unique life history in which individuals transform their sex. Almost all shrimp initially develop as males, though initial development as females has been reported in P. goniurus and P. hypsinotus (McCrary in Haynes and Lehman 1969). Shrimp reach maturity as males in two years. At two and one-half years, most breed as males, though at three and one-half years a few have already transformed into females (Ivanov 1969). McCrary found six months to be the average time required for an individual to change sex (Haynes and Lehman 1969). By four and one-half years of age, all shrimp change to breeding females. Few females apparently live beyond six years (Ivanov 1969). Figure 99 presents the early life history and life cycle for P. borealis. Shrimp feed principally upon zooplankton (Barr in Haynes and Lehman 1969). The most common item identified in food studies on shrimp was brachyuran crab larvae. The average size of shrimp in the Kodiak area is larger than that of shrimp caught in the Shumagin area. Shrimp near Sanak Island were the smallest measured (Ivanov 1964). Ivanov (1969) attributed this to the warmer currents in the Kodiak area, which cool as they run westward. Shrimp are measured for carapace length from the posterior of the eye socket to the posterior lateral edge of the carapace. In the Shumagins, Ivanov (1969) found P. borealis males to average 19 mm. at first breeding (two and onehalf years), and females to average 25 mm. at first spawning (four and onehalf years). Molting pattern is not well known. Females molt into a special shell prior to breeding which has hairs for egg attachment. Upon hatching the eggs, females molt back into nonbreeding shells (Ivanov 1964). Fox (1973) has prepared a general summary of shrimp and shrimp fishing in the Eastern Gulf of Alaska. Scallops An Alaskan scallop fishery has been developed in the Gulf of Alaska within the past five years and has produced a peak harvest of slightly more than 600 metric tons from the Kodiak area in 1970. The weathervane scallop, Patinopecten caurinus, is the only one of eight scallop species in the Gulf of Alaska that is large enough or sufficiently abundant to support commercial development (Hennick 1973). Major commercial fishing areas are shown on Figure 100. Exploratory fishing drags by the National Marine Fisheries Service assisted in locating important scallop beds (National Marine Fisheries Service, undated; U.S. Bureau of Commerical Fisheries 1968). In addition to the exploratory trawl reports, moderate fishing effort identified one new bed running from Cape Ikolik towards Afognak Island on the east side of Shelikof Strait (Hennick 1973). Scallop beds generally appeared compact and restricted in area. Drags adjacent to a rich scallop bed produced little, yet drags in the main bed yielded high poundage. EARLY LIFE SPAWNING HISTORY ; 5 # LARVAE HATCH FREE-SWIMMING LARVAE PRESENT LARVAE SETTLE TO BOTTOM Lp | | } | JAN. FEB MAR. APR. MAY ; . . SEP OCT. NOV. DEC. MATURE FEMALES MATURE MALES JUVENILE SHRIMP IN SHALLOWS FREE-SWIMMING LARVAE ! 1 1 i 2 3 = 5 YEARS OF AGE Figure 99. Early life history and life cycle of pink shrimp, Pandalus borealis (from Haynes and Lehman 1969, Ivanov 1969). @sz 164° 162° 160° 158° 156° 154° 152° 150° 59° YZ, “AOR FISHING GROUNDS . |Z UA 56° 55° 54° 164° 162° 160° 158° 156° 154° 152° 150° Figure 100. Location of major scallop beds fished commercially in the Western Gulf of Alaska (from Fay 1972). 57° 56° 55° 54° | 66% 260 Large trawl catches were made on the western end of Portlock Bank, the western end of Marmot Flats, along the 100 m. contour of Albatross Bank, Beaver and Pavlof Bays (Figure 101). The latter location does not sustain a commercial fishery. Caution, similar to that expressed for benthic fauna, should be observed in the interpre- tation of trawl catches. National Marine Fisheries Service drags found concentrations of scallops between 42 and 138 m. with the majority located from 60 to 100 m. (National Marine Fisheries Service, undated; U.S. Bureau of Commercial Fisheries 1968). The most productive dredge yielded 703 kg./hr. Hitz and Rathjen (1965) reported that scallops composed 1 percent of the invertebrate biomass in the Eastern Gulf. The Yakutat and Kodiak areas produce the entire commercial harvest for the Gulf of Alaska. Life history information on the scallop in the Western Gulf of Alaska is limited. Scallops mature sexually in their third year when they may be 80-125 mm. from umbo to outer shell margin. Spawning in the Kodiak area begins in early June and may continue into early July (Hennick 1970). Scallops do not move to special areas for breeding. Fecundity has not been studied in this species. At spawning, males and females release sperm and eggs into the water where fertilization occurs. Fertilized eggs settle to the bottom and adhere to the substrate. After two or three days, these eggs hatch and larvae begin a two and one-half week planktonic phase. At the end of this time, the individual settles to the bottom as a juvenile (Hennick 1973). Hennick (1970) believes a single ring is added to the dorsal valve of the shell for each year of growth. Scallops may live more than 15 years; one exceptional specimen has been reported with 28 annual rings (Hennick 1973). Most scallops caught commercially at Kodiak are seven to eleven years of age. Maximum size of specimens has exceeded 225 mm. valve height. A dredge ring (minimum size of 102 mm. diameter) restricts the harvest to large individuals, but may allow only one breeding season prior to exposure of scallops to the fishery. The early life history and life cycle of this species are presented in Figure 102. Areas commerically harvested generally have mud, clay, sand, or gravel substrates. Little is known of the abundance of scallops in more rocky areas, because trawling is difficult in such areas. Juvenile tanner crab are commonly encountered in scallop hauls and appear to occupy a similar habitat. King crab and Dungeness crab are encountered less often. Scallop dredging is restricted during seasons of high potential conflict, such as the king crab ' breeding season (Hennick 1973). @ 90-270 KG/HR. xX MORE THAN 270 KG/HR. Figure 101. Location of large trawl catches of scallops reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 192 EARLY LIFE HISTORY PLANKTONIC LARVAE PRESENT EGGS DEVELOP ON BOTTOM SPAWNING OCCURS Ll 1 1 Jt 1 | 1 1 1 ! 4 jd JAN. FEB. MAR. APR. MAY. JUN. JUL. AUG. SEP. OCT. NOV. DEC. LIFE CYCLE JUVENILES ‘ m TE PLANKTONIC LARVAE L tL 1 1 1 1 1 _L 1 L _|_ O° ' 2 3 4 5 6 7 8 9 10 YEARS OF AGE | caurinus {from gure 102. Early life tory and life cycle of the weathervane scallop, Patinopecten Hennick 19°70, 1975). 7TH 263 PELAGIC FAUNA Pelagic Invertebrates Squid are the only pelagic invertebrates mentioned in the literature as significant in the Western Gulf. Exploratory fishing drags of the National Marine Fisheries Service (undated) contained squid in small quantities at only two stations east and north of Sitkalidak Island. The U.S. Bureau of Land Management (1973) reported that squid use the intertidal and nearshore subtidal area of the Gulf of Alaska for spawning. Scheffer (1959) collected a squid, Rossia pacifica, stranded on a beach at Unimak Island after a storm. Fish Noncommerical species as well as undeveloped commercial stocks have been identified in the Western Gulf of Alaska by various authors. Exploratory fishing drags of the National Marine Fisheries Service (undated) yielded 18 groups which might be categorized here (Table 34). All drags yielding over 90 kg./hr. were plotted in Figure 103. Table 35 lists taxa which have been reported from all sources in the Western Gulf. Similar caution, as mentioned previously for benthic fauna, should be observed in the interpretation of these trawl data. A regular pattern of stations throughout the continental shelf of the Western Gulf of Alaska was repetitively sampled during summer, fall, and winter seasons by the International Pacific Halibut Commission (1964) during 1961-1962 (Figure 81). Incidental catches of elasmobranches, sculpins, grenadiers (rattails), ronquils, and rockfish (other than Pacific Ocean perch) exceeding 90 kg./hr. are plotted in Figure 104. Similar caution, as mentioned previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. Rockfish and grenadiers were found in quantity only at the continental shelf edge and slope. Elasmobranches were recorded in large quantity only in Shelikof Strait and north of Afognak Island. Sculpins and ronquils were abundant throughout the entire continental shelf area. Hitz and French (1965) pointed to the possibility of a commercial fishery for pomfret, Brama japonica, which were particularly abundant offshore southwest of Kodiak. A study of epipelagic fishes caught incidentally during salmon high seas sampling, reported Atka mackeral, Pleurogrammus monoterygius ; jack mackerel, Trachurus symmetricus, and pomfret, Brama japonica, as frequently encountered in the Northern Gulf (Larkins 1964). Sebastes aleutianus and Sebastolobus sp. were two groups of rockfish which Alverson et al. (1964) reported were increasingly abundant with depth in the Alaska Peninsula region. Maximum catches were reported between 365 and 550 m. Noncommercial Fishes Reported from 1,296 Exploratory Fishing Drags of the National Marine Fisheries Service in the Western Gulf of Alaska (from TABLE 34 National Marine Fisheries, undated) 10. 11. 12. 13. 14. 15. 16. 17. 18. Group Sculpin Capelin Smelt Rockfish (ex. S. alutus) Ronquil Eelpout Hake Sandfish Pricklebacks Skate Blennies Atka Mackerel Lumpsucker Giant Wrymouth Eel Tomcod Greenlings Sand Lance Poachers Occurrence abundant common common moderate moderate moderate occasional occas. occas. occas. occas. occas. Rare Rare Rare Rare Rare Rare Maximum Catch (kg./hr.) 315 660 115 890 100 70 155 85 85 70 40 20 65 20 10 Trace Trace Trace 264 x SCULPIN @ CAPELIN @ sme.t @ Ronou @ HAKE (@ ROCKFISH (EXCLUDING PACIFIC OCEAN PERCH) Figure 103. Location of large trawl catches of noncommercial fish reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). g97@ TABLE 35 Noncommercial Fishes of The Western Gulf of Alaska (from Quast and Hall 1972; Larkins 1964; Marine Advisers 1971) Family Agonidae (poachers) Anoplagonus inermis Aspidophoroides bartoni Asterotheca alascana A. infraspinata Bathyagonus nigripinnus Bothragonus swani Pallasina barbata Podothecus acipenserinus Sarritor frenatus Ss. leptorhynchus ~ Family Ammodytidae (sandlances) Ammodytes hexapterus Family Bathylagidae (deepsea smelts) Bathylagus stilbius Family Bathymasteridae (ronquils) Bathymaster caeruleofasciatus B. signatus Ronquilus jordani Family Bramidae (pomfrets) Brama japonica Family Carangidae (jacks and scads) Trachurus symmetricus Family Cottidae (sculpins) Artediellus pacificus Blepsias bilobus Cottus aleuticus Dasycottus setiger Enophrys diceraus Eurymen gyrinus Gymnocanthus galeatus G. pistilliger tricuspis (7?) Hest Lepidotus sp. jordani fei tripterus villosus Icelinus borealis jeelus spatula - spiniger i. uncinalis Leptocottus armatus Malacocottus kincaidi Myoxocephalus sp. M. jaok M. polyacanthocephalus Nautichthys pribilovius Oxycottus acuticeps Radulinus asprellus Triglops Triglops forficata T. macellus T. metopias + pingeli T T. scepticus Ulca bolini 266 267 TABLE 35, Continued. Family Cyclopteridae (lump fishes and snailfishes) Aptocyclus ventricosus Cyclopteropis phrynoides Careproctus abbreviatus Eumicrotremus orbis C. colletti Liparis cyclostigma C. gilberti L. dennyi C. ostentum L. mucosus C. spectrum L. ochotensis Family Hexagrammidae (greenlings) Hexagrammos decagrammus H. stelleri Pleurogrammus momopterygius Ophiodon elongatus Family Gadidae (cods) Antimora rostrata Eleginus gracilis Microgadus proximus Family Lamnidae (mackerel sharks) Lamna ditropis Family Lumpenidae (Eel-blennies) Lumpenus sagitta Family Macrouridae (rattails) Coryphaenoides sp. Family Merluccidae (Hake) Merluccius productus “Family Osmeridae (smelt) Hypomesus pretiosus Mallotus villosus Osmerus eperlanus Spirinchus thaleichthys Thaleichthys pacificus Family Petromyzontidae (lampreys) Lampetra japonica Family Pholididae (gunnels) Apodichthys flavidus Family Psychrolutidae Psychrolutes paradoxus Family Rajidae (skates) Raja kincaidi Family Scombridae (tunas) Thunnus thynnus Family Scorpaenidae (rockfishes) Sebastes aleutianus S. polyspinis TABLE 35, Continued. S. ciliatus S. diploproa S. melanops S. mystinus (?) Family Squalidae (dogfishes) Squalus acanthias Family Stichaeidae (pricklebacks) Anisarchus medius Chirolophis polyactocephalus Delopepis gigantea Leptoclinus maculatus Family Trichodontidae (sandfishes) Trichodon trichodon Family Zoarcidae (eelpouts) Embryx crotalina Lycodes brevipes L. diapterus S. variegatus S. zacentrus Sebastolobus sp. S. alascanus Lumpenella longirostris Lumpenus sagitta Lyconectes aleutensis Xiphister atropurpureus 268 RONQUIL ROCKFISH ® ELAsmosRANCHS Figure 104a. Location of large trawl catches of noncommercial fish reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). 692 @ SCULPIN X GRENADIER Figure 104b. Location of large trawl] catches of noncommercial fish reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). 022 271 Elasmobranches, both Rajidae and Squalus acanthias, were encoun- tered in small numbers at all depths with skates (Rajidae) found in slightly greater abundance (Alverson et al. 1964). Sculpins and rattails comprised the highest proportion of miscellan- eous fish encountered by Alverson et al. (1964). Sculpins were most frequent from the surface to 185 m., while rattails were the dominant roundfish below 365 m. off the Alaska Peninsula. The Faculty of Fisheries (1957, 1961, 1966, 1968, 1969) reported species identified from larvae obtained in plankton tows and adults caught in bottom trawls. Scheffer (1959) and Marine Advisers (1971) recorded several additional inshore species. Quast and Hall (1972) have systematically reviewed Alaskan fishes. All species recorded in the study area are included in Table 35. Pollock Pollock, Theragra chalcogrammus, in the North Pacific (primarily in the Bering Sea) have yielded the largest annual harvest of food fish in the world since the decline of the South American anchoveta fishery. Catches in the Western Gulf have grown dramatically in the past decade with combined harvests by Japan and the USSR now totaling over 10,000 metric tons annually. The United States has never harvested this species in quantity (Buck 1973). Pollock are regularly harvested from the area shown in Figure 105 in the Western Gulf. Exploratory fishing drags of the National Marine Fisheries Service (undated) indicated a major concentration of pollock southeast of Kodiak Island along the edges of Albatross Bank (Figure 106). Many large catches were made in late spring between 110 and 155 m., although good quantities were evident from 75 to 265 m. Catches to nearly 12,000 kg./hr. were reported. Caution, similar to that mentioned previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. A more recent National Marine Fisheries Service survey conducted in 1972 in the Kodiak area and reported by Alton and Nicholl (1973) found pollock concentrated in the same areas between 110 and 240 m. Catches averaging 710 to 890 kg./hr. were calculated, indicating a substantial resource (Figure 107). The International Pacific Halibut Commission (1964) reported catches of pollock in excess of 90 kg./hr. at the station locations indicated in Figure 108. Pollock were taken in quantity along the continental shelf edge and along gullies and canyons within the shelf. Caution, similar to that mentioned previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. An early estimate by the U.S. Bureau of Commercial Fisheries (1965) placed the potential annual harvest of pollock for the Alaska Peninsula between 4.2 and 5.6 thousand metric tons. These fish ranged 59° 58° 57° 56° 55° 54° 164° 162° 160° 158° 156° . i 154° 152° 150° Figure 105. Location of pollock grounds fished commercially in the Western Gulf of Alaska (from National Marine Fisheries Service, various months). KM CW MAJOR FISHING GROUNDS 164° 162° 160° 158° : 156° 154° 152° 150° Tle X MORE THAN 270 KG/HR. Figure 106. Location of large trawl catches of pollock reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). €LZ | oon | “trinity 1s, a I (OM) '2 kG/HR E=——] 15 KG/HR | 700-900 KG/HR |. 160° 140° Figure 107. Pollock distribution and potential in the Kodiak vicinity (from Alton and Nicholl 1973). @ TRAWL YIELD EXCEEDING 90 KG/HR. Figure 108. Location of large trawl catches of pollock reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). SZZ 276 in length from 22 to 62 cm. and averaged 33 cm. The 1972 survey found 38 to 46 cm. fish to be the most frequently encountered size class of adults off Kodiak (Alton and Nicholl 1973). The Food and Agriculture Organization of the United Nations (1972) estimated the maximum annual yield of the entire Northern Gulf of Alaska to be 25,000 metric tons. On the Alaska Peninsula, pollock may occur at greater depths than off Kodiak. Alverson et al. (1964) found the maximum average catch on the Alaska Peninsula between 275 and 365 m., decreasing progressively at shallower depths. In Shelikof Strait, they calculated maximum average catches from 180 to 275 m. Life history of the pollock has not been studied in the Western Gulf. In other North Pacific areas, pollock form dense schools in their spawning migrations during late winter through early summer to inshore shallows where they spawn from 200,000 to 1.5 million eggs. These eggs are planktonic, and hatch in the upper water in 12 days at 6 to 7 degrees C as they float with the currents (Kasahara 1961). As juveniles develop, they progressively become more bottom- dwelling in habit. Pollock mature at three to four years when they are 30 to 40 cm. in length. Pollock may live as long as twelve to fifteen years (Alton and Nicholl 1973). Early life history and life cycle are depicted in Figure 109. Pollock prefer planktonic crustaceans and small fish as food. Alton and Nicholl (1973) reported daily vertical movements of both juveniles and adults which are probably related to feeding habits. Kasahara (1961) reported temperature to be important in determining area and vertical distribution. Pacific Cod The earliest commercial fishery in the study area was based on Pacific cod, Gadus macrocephalus. This fishery was developed by the United States shortly before the purchase of Alaska, but U.S. participation has declined. Less than 1,500 metric tons per year are now harvested by Japan all along the Gulf Coast incidental to blackcod and Pacific Ocean perch fisheries (Buck 1973). Exploratory fishing drags of the National Marine Fisheries Service (undated) located scattered concentrations of Pacific cod south and east of Kodiak as well as west of the Shumagin Islands (Figure 110). Large quantities were found at depths between 80 and 215 m. with no optimum depth discerned. This species was moderately abundant throughout the trawling period from late spring to early autumn. Caution, similar to that mentioned previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The International Pacific Halibut Commission (1964) reported catches of Pacific cod in excess of 90 kg./hr. at station locations indicated in Figure 111. Pacific cod were taken in quantity along the outer continental shelf and along gullies and canyons within the shelf. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. EARLY LIFE HISTORY PELAGIC EGGS AND LARVAE SPAWNING Db l tt | J JAN. FEB. MAR. APR. MAY JUN. JUL. AUG. SER OCT. NOV. DEC. LIFE CYCLE MATURE ADULTS — > ° | 2 3 4 5 6 7 8 9 lo YEARS OF AGE Figure 109. Early life histor, and ffrom Kacahara i9#}, A lcogrammus lite cyele of pollock, Theragra ltor and Nicholi i975 2lz @ 90-270 KG/HR. x MORE THAN 270 KG/HR. Figure 110. Location of large trawl catches of Pacific cod reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 822 @ TRAWL YIELD EXCEEDING 90 KG/HR Figure lll. Location of large trawl catches of Pacific cod reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). 627 280 The U.S. Bureau of Commercial Fisheries (1965) found Pacific cod most abundant at depths less than 90 m. in Gulf of Alaska and Alaska Peninsula waters. For the Alaska Peninsula, the potential annual yield was estimated at between 4.1 and 5.4 thousand metric tons. The Food and Agriculture Organization of the United Nations (1972) estimated the maximum sustainable annual yield of the entire Northern Gulf of Alaska to be 30,000 metric tons. Alverson et al. (1964) found this species to be the dominant roundfish in waters of less than 180 m. deep over the continental shelf in the study area. Greatest average catches were found between 90 and 180 m. with fish from 22 to 72 cm. in length (average length was 42 cm.). Pacific cod have well-defined seasonal movements which appear to be controlled by temperature. They migrate to deeper offshore waters for the winter. The life history of the Pacific cod has not beeen studied in the Western Gulf. In other North Pacific areas, spawning generally takes place during late winter and spring with 1.4 to 6.4 million eggs per female sinking to the bottom where they hatch in 20 days at 4 degrees C (Kasahara 1961). Maturity is reached in two to three years in British Columbia, and individuals may live eight to ten years (Nanaimo Biological Station 1966b). Kasahara (1961) reported Soviet studies in colder waters where these fish do not mature until five to nine years of age. Early life history and life cycle are shown on Figure 112. This species feeds upon other bottom fish and crustaceans. In coastal areas, herring may become important as food. Growth is rapid; individuals may reach a length of 60 cm. in three to five years. Blackcod Blackcod, also called sablefish, have supported a Japanese fishery harvesting less than 5,000 metric tons annually in the study area this past decade with only token United States harvest (Buck 1973). South Korea has recently begun fishing for blackcod off Kodiak. Blackcod are regularly harvested from the area shown in Figure 113 in the Western Gulf. Blackcod, Anoplopoma fimbria, were uncommon in exploratory fishing drags of the National Marine Fisheries Service (undated) because these fish occur at depths which were not trawled sufficiently (Figure 114). Substantial quantities were encountered from 115 to 465 m. Blackcod are believed to migrate to even deeper waters during the winter, and this might be associated with spawning activity (Reeves 1972). Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The International Pacific Halibut Commission (1964) reported catches of blackcod in excess of 90 kg./hr. at station locations indicated in Figure 115. Blackcod were taken throughout the Western Gulf along the continental shelf edge and margin. Caution, similar to that mentioned previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. EARLY LIFE HISTORY SPAWNING l | ! ! | L 1 | 1 | ! 1 —_I JAN. FEB MAR. APR. MAY JUN. JUL. AUG. SEP OCT. NOV. DEC LIFE CYCLE ! 10 YEARS OF AGE Figure 112. Early life history and life cycle of Pacific cod, Gadus macrocephalus (from Kasahara 1961, Nanaimo Biological Station 1966b). La 18% 59° 58° 57° 55° 54° 164° Figure 113. 162° 160° Location of major blackcod and Pacific Ocean perch grounds fished commercially in the Western Gulf of A- laska (from National Marine Fisheries Service, various months). MAJOR FISHING GROUNDS 150° 158° 1s2° 150° 59° 57° 54° we @ 45-270 KG/HR. x MORE THAN 270 KG/HR. Figure 114. Location of large trawl catches of blackcod reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). £872 @ TRAWL YIELD EXCEEDING 90 KG/HR. Figure 115. Location of large trawl catches of blackcod reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). v8z 285 The U.S. Bureau of Commercial Fisheries (1965) found blackcod to be the dominant deepwater fish in the Alaska Peninsula region, being most abundant at depths of between 365 and 550 m. on the continental slope. The potential annual yield from the Alaska Peninsula was calculated between 6.3 and 9.1 thousand metric tons of fish averging 51 cm. in length. The Food and Agriculture Organization of the United Nations (1972) estimated the maximum sustainable yield of the entire Northern Gulf of Alaska to be 18,000 metric tons annually. Life history of the blackcod has not been studied in the Western Gulf. In other North Pacific areas, spawning takes place in the late winter after which developing eggs and larvae float in the surface water. Immature fish, less than 30 cm. in length, may school in surface coastal waters and at shallow depths. Early life history and life cycle are depicted in Figure 116. Blackcod mature in six to eight years, although they may reach commercial size in only five years. Food consists of small fish and crustaceans (Nanaimo Biological Station, undated). Individuals may live nine years or more (Reeves 1972) and exceed 4 kg. in weight and 75 cm. in length (Shubnikov 1963). Herring A substantial herring fishery has existed in the Kodiak district throughout the second quarter of this century, reaching a peak of more than 45,000 metric tons in 1947. Large numbers of herring, Clupea harengus pallasii, were found in almost all Kodiak Island bays (Figure 117). After the market for reduction herring collapsed in the late 1950s, a limited Japanese market for herring roe kept the fishery going (U.S. Army, Corps of Engineers 1973). In recent years, the fishery has concentrated in Uyak, Uganik, and Chiniak Bays and in the Old Harbor area (Alaska Department of Fish and Game 1973b). Few large catches of herring were caught in the exploratory fishing drag program of the National Marine fisheries Service (undated), since these fish are not regularly concentrated near the bottom in deeper waters. Catches which exceeded 90 kg./hr. were taken during September in bays on both sides of Shelikof Strait. Limited data on herring life history have been collected within the Western Gulf of Alaska. Gulf of Alaska herring remain inshore during most of their life cycle. Spawning takes place along the shore from late April to early June in the Kodiak area. Females discharge eggs which are fertilized by milt (spermatozoa) released by the males. Fertilized eggs adhere to kelp, eelgrass or any convenient substrate. Individual females deposit an average of 20,000 eggs each year (Nanaimo Biological Station 1966c). Eggs develop for about 16 days before hatching into planktonic larvae. Mortality in the egg and larval stages can be quite variable. It may be excessive in some years, resulting in the dominance of individ- ual year classes in herring populations. Herring gradually develop from larvae into juveniles during a two-month planktonic existence. Juvenile herring form schools and frequent kelp beds for protection during the summer. EARLY LIFE HISTORY SPAWNING JAN. FEB. MAR. APR. MAY JUN. JUL AUG. SEP. ocT. NOV. DEc. MATURE ADULTS : is JUVENILES 4 5 6 7 8 9 10 YEARS OF AGE Figure 116. Early life history and life cycle of blackcod, Anoplopoma fimbria (from Nanaimo Biological Station, undated). | oe " Trinity Is, a \ |. SHUYAK STRAIT CS 2. RED & BLUE FOX BAY 3, PARAMANOF BAY 4. MALINA BAY 5. RASPBERRY STRAIT 6 DRY SPRUCE BAY 7. UGANIK BAY & SPIRIDON BAY 9 ZACHER BAY 10. UYAK BAY 11. STURGEON RIVER AREA 12. SITKINAK LAGOON 13. KIAVAK LAGOON 14 THREE SAINTS BAY 15 OLD HARBOR AREA 16. SITKALIDAK STRAITS 17. PORT HOBRON 18. KILIUDA BAY 19. SHEARWATER BAY 20. CHINIAK BAY 21. KIZHUYAK BAY _22. 1IZHUT BAY 180° Figure 117. Location of major herring grounds fished commercially in the Kodiak vicinity (from U.S. Army, Corps of Engineers 1973). 288 Juveniles move slightly offshore in early autumn. Few details are known about juvenile life history prior to three or four years of age, when individuals first return to spawn (Nanaimo Biological Station 1966c). Tagging programs may be able to delineate separate migratory populations, but no studies of this scope have been undertaken within the Western Gulf. Early life history and life cycle are shown in Figure 118. Herring feed upon zooplankton and migrate vertically in pursuit of this diet. Growth has not been adequately studied in the Gulf region, although fish older than six or seven years are only rarely encountered (Reeves 1972). Pacific Ocean Perch Soviet and Japanese trawlers have fished extensively for Pacific Ocean perch, Sebastes alutus, within the study area throughout the past decade with harvests approaching 50,000 metric tons in the mid- 1960s (Buck 1973). Soviet literature has contributed substantially to our understanding of this species and its life history. Pacific Ocean perch are regularly harvested from the areas shown in Figure 113 in the Western Gulf. Exploratory fishing drags by the National Marine Fisheries Service (undated) recorded large quantities of this species east of Kodiak Island over the outer continental shelf and slope (Figure 119). Scattered concentrations were also recorded in the Shelikof Strait. Fish appear concentrated between 160 and 250 m. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The International Pacific Halibut Commission (1964) reported catches of Pacific Ocean perch in excess of 90 kg./hr. at the station location indicated in Figure 120. Pacific Ocean perch were taken in quantity along the continental shelf edge and along gullies and canyons within the shelf. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The U.S. Bureau of Commercial Fisheries (1965) identified large concentrations between 200 and 300 m. in Seward and Albatross Gullies, south of Unimak Pass, and in the canyon entering Shelikof Strait. Generally, fish were encountered 20 to 60 m. above rocky bottoms and in submarine canyons and gullies. Fish ranged from 17 to 43 cm. in length and averaged 35 cm. The potential annual yield for the Alaska Peninsula region was calculated to be between 4.5 and 13.6 thousand metric tons. The Food and Agriculture Organization of the United Nations (1972) estimated the maximum sustainable yield of the entire Northern Gulf of Alaska to be 95,000 metric tons annually. Soviet investigations (Lyubimova 1965) found Pacific Ocean perch inhabiting depths of 100 to 450 m. or more. Concentrations were associated with the Alaska Current in temperature regimes of 4 to 6.5 degrees C. Maximum concentration occurs during summer and autumn east and southeast of Kodiak Island, southwest of the Shumagin Islands, and south of Unimak Island (Figure 121). EARLY LIFE HISTORY PLANKTONIC LARVAE DEVELOPING EGGS SPAWNING l | ! | 1 1 | _|___ LIFE CYCLE MATURE ADULTS JUVENILES PLANKTONIC LARVAE ° | 2 3 4 5 6 7 8 9 10 YEARS OF AGE Figure 118. Early life history and life evcle of herring, Clupea harengus pallasii (from Nanaimo Biological Station 1966c). 687 @ 90-270 KG/HR. x MORE THAN 270 KG/HR. Figure 119, Location of large trawl catches of Pacific Ocean perch reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 062 @ TRAWL YIELD EXCEEDING 90 KG/HR Figure 120. Location of large trawl catches of Pacific Ocean perch reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964), T6Z ROCKFISH CONCENTRATIONS —— CURRENTS Figure 121, Concentrations of Pacific Ocean perch reported in Soviet investigations (from Lyubimova 1965). 762 293 Pacific Ocean perch stocks of the Western Gulf of Alaska are highly mobile and undertake substantial seasonal migrations (Lyubimova 1965). These movements appear linked to reproduction and wintering activities of the species. Following copulation, which occurs within the previously mentioned concentration areas in late September through November, females depart for the northern part of the Gulf, traveling eastward from Portlock Bank. Arriving in January, the females have avoided the cooler winter water temperatures of the Western Gulf. Males congregate for overwintering in the Chirikof-Kodiak Island area or further north. Their migration to wintering areas occurs in late December and January. As waters warm in spring and zooplankton populations increase, Pacific Ocean perch gradually return to the Western Gulf. Concentrations may reappear in March or April off Kodiak Island, and as late as July or August in the Unimak area. Limited data on Pacific Ocean perch life history have been collected by Soviet investigators within the Western Gulf. Pacific Ocean perch mature initially at five to seven years when they are 24 to 27 cm. in length. Fertilization in late September and October is internal and precedes the wintering migration of females. Depending on the size of the female, from 10,000 to 300,000 eggs develop internally until larvae are expelled in late April to early June (Lyubimova 1964). Larvae may be released at depths of 200 to 250 m., slightly above the bottom. Highest larval abundance has been observed in the Yakutat area, decreasing to its lowest point off Unimak Island (Lisovenko 1964). Juvenile rockfish are generally found in cooler, shallower water of the Western Gulf. They gradually become more demersal in habit during their third year of life. Early life history and life cycle are depicted in Figure 122. Individual Pacific Ocean perch reach a maximum length of 50 cm. and a maximum age of 30 to 35 years (Reeves 1972). Active feeding and weight gain occur primarily in the feeding concentrations along the outer shelf and slope from May to September. Although their diet is composed primarily of planktonic crustaceans, some feeding occurs upon benthic species of mollusks and small fish. Diurnal, vertical movements of Pacific Ocean perch are believed to be associated with feeding behavior (Lyubimova 1965). Individuals may reduce their food intake in autumn and winter; adults usually do so to a greater extent than young fish. Flatfish (excluding halibut) The commercial harvest of flatfish in the Western Gulf peaked at slightly less than 6,000 metric tons annually in the late 1960s. The current areas fished for these species are shown in Figure 123 (Buck 1973). Flatfish accounted for more than 50 percent of all fish caught during exploratory trawling on the inner continental shelf (Alverson et al. 1964). Thirteen species of flatfish, excluding halibut, were recorded from exploratory fishing drags of the National Marine Fisheries Service (undated) in the Western Gulf of Alaska (Table 36). EARLY LIFE FEMALES EXPELL LARVAE HISTORY 3 WEST WaRD RETURN MIGRATION MALES MIGRATE TO KODIAK AREA FEMALES MIGRATE INTO EASTERN GULF COPULATION L 1 ! ! t 1 ! ! JAN. FEB. MAR. APR. MAY JUN. JUL. AUG. SEP. OcT. NOV. DEC. LIFE CYCLE MATURE ADULTS DEMERSAL JUVENILES SEMI-PELAGIC JUVENILES ! 1 {| | i Lt 4+ 5 6 7 8 =) lo YEARS OF AGE Figure 122. Early life history and life cycle of Pacific Ocean perch, Sebastes alutus (from Sisovenko 1964, Lyubimova 1964). v6z 295 é Albatross Be Bank (te Trinity Is, BZZZ MAJOR FISHING GROUNDS 7 ee | 83° 182” 180° 148° Figure 123. Location of flatfish grounds fished commercially in the Western Gulf of Alaska (from National Marine Fisheries Service, various months). TABLE 36 296 Flatfish (excluding halibut) species of the Western Gulf of Alaska (from Alverson et al. 1964; National Marine Fisheries Service, undated) 10. 11. 12. iS: Scientific Name Atheresthes stomias Citharichthys sordidus Glyptocephalus zachirus Hippoglossoides elassodon Isopsetta isolepis Lepidopsetta bilineata Limanda_ aspera Lyopsetta exilis Microstomus pacificus Parophrys vetulus Platichthys stellatus Pleuronectes quadrituberculatus Psettichthys melanostictus Common Name Turbot Mottled sand dab Rex sole Flathead sole Butter sole Rock sole Yellowfin sole Slender sole Dover sole English sole Starry flounder Alaska Plaice Sand Sole 297 Only seven species were caught at a rate of 90 kg./hr. or greater. The locations of large catches for these species are indicated in Figure 124. Many large catches were taken on the continental shelf and slope east of Kodiak Island. Turbot and flathead sole yielded the greatest number of large catches and are the most abundant species of flatfish with potential commercial value in the Western Gulf. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. The International Pacific Halibut Commission (1964) reported flatfish catches in excess of 90 kg./hr. at the station locations indicated in Figure 125. Rex and dover soles were found in quantity along the continental shelf edge and slope. Yellowfin sole in inshore shallows and butter sole along bank edges were seldom found in abundance. Rock sole were abundant throughout the study area on offshore banks. Turbot and flathead sole were regularly encountered in large quantity in canyons and gullies on the continental shelf. Caution, similar to that expressed previously for benthic fauna, should be observed in the interpretation of incidental trawl catches. Distribution of species is related to depth (Alverson et al. 1964). Eight species can be considered shelf inhabitants with their maximum catches recorded at depths less than 90 m. (Table 37). The flathead sole inhabits intermediate depths. The remaining species were most abundant at depths in excess of 275 m. Turbot has the most commercial potential of the flatfish species in the Western Gulf (U.S. Bureau of Commercial Fisheries 1965). It is the most abundant flatfish species as well as having the largest average size of 37 cm. Potential annual yield for the Alaska Peninsula region alone is estimated at between 20.4 and 27.2 thousand metric tons. The Food and Agriculture Organization of the United Nations (1972) estimated the maximum sustainable yield of the entire Northern Gulf of Alaska to be 60,000 metric tons annually. Shuntov (1965) found that adult turbot preferred water temperatures of 3 to 4 degrees C. Juveniles are found in shallow water. Shuntov believes that adult migrations to the shallows for spawning, rather than planktonic egg and larval drift or juvenile migration, are primarily responsible for this characteristic. Flathead and rock sole are also abundant in the Alaska Peninsula region. Their respective potential annual yields have been estimated at 5.4 to 6.8 thousand and 10.4 to 13.6 thousand metric tons (U.S. Bureau of Commercial Fisheries 1965). The Food and Agriculture Organiz- ation of the United Nations (1972) estimated the maximum sustainable yields for the entire Northern Gulf of Alaska for these species to be 20,000 and 15,000 metric tons respectively. Flatfish reproduction and life cycles are not well known. Spawning is believed to occur in late winter through early summer in coastal shallows. Eggs of such species as yellowfin sole are believed to be pelagic, while others such as rock sole are considered demersal. Large flatfish may spawn in excess of two million eggs in a season. Size at maturity and life span are not known (Nanaimo Biological Station, undated). @ YELLOWFIN SOLE @ DOVER SOLE X HALIBUT @ FLATHEAD SOLE Figure 124a. Location of large trawl catches of flatfish reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 862 @ REX SOLE @ ALASKA PLAICE X ROCK SOLE @ TURBOT Figure 124b. Location of large trawl catches of flatfish reported by the National Marine Fisheries Service in the Western Gulf of Alaska; unweighted composite of data collected over a period of 23 years (from National Marine Fisheries Service, undated). 662 & BUTTER SOLE >< DOVER SOLE © YELLOWFIN SOLE @ TURBUT Figure 125a. Location of large trawl catches of flatfish reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). OO0€ @ Rex sove X ROCK SOLE @ FLATHEAD SOLE Figure 125b. Location of large trawl catches of flatfish reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). TOE TABLE 37 Pounds of Flatfish caught per hour of Exploratory trawling by Depth Intervals in the Alaska Peninsula Region (from Alverson et al. 1964) Species Atherestes Citharichthys Glyptocephales Hippoglossoides Isopsetta Lepidopsetta Limanda Microstomus Parophrys Platichthys Pleuronectes Psettichthys (T = Trace) 1-90 26 21 159 13 Depth in Meters 90-181 182-272 273-364 137 541 992 1 T 0 4 34 26 80 145 31 1 T T 46 3 0 8 0 0 1 6 29 T 0 0 T 0 0 T T 0 T 0 0 365-547 698 0 120 302 303 Food generally consists of benthic invertebrates and small fish, but varies widely between species (Kasahara 1961). Halibut Halibut, Hippoglossus stenolepis, have long supported a commercial fishery in the Gulf of Alaska with harvests in the Western Gulf approaching 15,000 metric tons in the mid 1960s (Buck 1973). Major fishing grounds for halibut in the Western Gulf are shown in Figure 126. Thompson and Van Cleve (1936) reported that along the Gulf coast, west of Cape Spencer, halibut are freely migratory and should be considered as a biological unit stock for management purposes. Halibut catches averaged highest in weight per hour trawled during exploratory fishing in waters less than 90 m. deep off the Alaska Peninsula. No other region in the Northeastern Pacific produced higher average catches. Over 95 percent of the halibut taken between Chirikof Island and the Shumagin Islands were less than 65 cm. in length (Alverson et al. 1964). International Pacific Halibut Commission (1964) trawl investigations found halibut most abundant between 65 and 140 m. in the vicinity of Chirikof Island and northest of Kodiak Island (Figure 127). Explora- tory fishing drags of the National Marine Fisheries Service (undated) recorded several large catches; most were located east of Kodiak Island in waters 50 to 130 m. deep (Figure 124). Caution, similar to that expressed previously for benthic fauna, should be observed in interpretation of incidental trawl catches of halibut recorded by the National Marine Fisheries Service. Halibut have been recorded at depths to 1,100 m. (Nanaimo Biological Station 1966d). The Food and Agriculture Organization of the United Nations (1972) estimated the maximum sustainable yield of the halibut for the entire Northern Gulf of Alaska to be 21,000 metric tons annually. Female halibut usually do not mature until ten to twelve years of age. Males may mature at seven to eight years (Bell and St. Pierre 1970). Spawning takes place from November to January at depths between 275 and 400 m. Large females may produce in excess of 2.5 million eggs during a spawning season. The specific gravity of the eggs and larvae enables them to remain suspended at midwater depths as they drift with ocean currents. Hatching occurs in about 20 days at 5 degrees C (Forrester and Alderdice 1973). As development proceeds, larvae rise closer to the surface. Inshore surface currents carry many larvae into coastal shallows favorable for growth. At an age of six to seven months, juvenile halibut settle to shallow bottoms. As they grow, they move into progressively deeper waters. 150° -4 a. | A 152° 154° 156° 158° grounds 160° commercially in the ot halibut 162° and St. Pierre 1970). MAJOR FISHING GROUNDS cation Western Gulf of Alaska (from fished Bell A\D\NDR 150° 152° 154° 156° 158° 160° 162° 164° @ TRAWL YIELD EXCEEDING 90 KG/HR Figure 127. Location of large trawl catches of halibut reported by the International Pacific Halibut Commission in the Western Gulf of Alaska (from International Pacific Halibut Commission 1964). soe While juvenile halibut may move only short distances, mature fish participate in extensive spawning migrations (more than 3,500 km. in one exceptional tagging return) (Bell and St. Pierre 1970). Halibut tagged off Cape Chiniak, Kodiak Island, have been recovered in significant numbers in British Columbia waters (International Pacific Halibut Commission 1973). Mature fish migrate eastward out of the Western Gulf of Alaska to spawn at the edge of the continental slope between Kodiak Island and Yakutat. Westerly currents return eggs and larvae to the Western Gulf where development of juveniles is completed in shallow bays along the Alaska Peninsula (Thompson and Van Cleve 1936). Important spawning grounds in the Western Gulf are located in Seward Gully and in the vicinity of the Trinity and Chirikof Islands (Bell 1972). Female halibut grow to a larger size than males. Males may attain ages of more than 25 years, weights up to 55 kg., and lengths to 140 cm. Females may attain ages exceeding 40 years, weights of 210 kg., and lengths of 240 cm. (Nanaimo Biological Station 1966d; Bell and St. Pierre 1970). Early life history and life cycle are depicted in Figure 128. Halibut feed primarily upon benthic fauna, including a large variety of fish as well as larger invertebrates. Juvenile halibut feed primarily on small crustaceans (Bell and St. Pierre 1970). Normally, temperatures between -3 and 9 degrees C are optimum for this species (Thompson and Van Cleve 1936). ° Salmon The five salmon species will each be discussed in detail in separate subsections. Figure 129 presents general information on Western Gulf of Alaska salmon populations. Summer high seas tagging locations of mature salmon returned from inshore areas in the Western Gulf of Alaska during 1964 and 1965 are shown (Hartt et al. 1965; Hartt et al. 1966). Caution must be used in interpreting salmon distribution from these data since they represent only a few months during two years on primarily mature fish. Juvenile salmon are found in coastal areas in the months immediately following their outmigration from fresh water prior to their emigration to oceanic feeding and rearing areas. Straty (in press) found most juvenile sockeye salmon to be concentrated in the upper few meters of surface waters within 40 km. of the coast in southern Bristol Bay. Hartt et al. (1966) found immature sockeye, pink, chum, and coho salmon in a belt within 32 km. of the coast along Southeastern Alaska. They stated that in areas with a wider continental shelf, distribution of fingerlings may extend further offshore. Salmon fingerlings were found moving southwestward through the Shelikof Strait in the Kodiak area. Chinook Salmon Chinook salmon, Oncorhynchus tshawytscha, are relatively scarce within the study area. Commercial catches are largest in the South EARLY LIFE HISTORY 3 PELAGIC LARVAE PELAGIC EGGS SPAWNING i HEESHEEE L | dt {dt 1 es JAN. FEB. MAR. APR. MAY JUN. JUL. AUG. SEP OCT. NOV. DEC. MATURE FEMALES LIFE CYCLE MATURE MALES PELAGIC LARVAE l 1 —t ! | L ! t ° \ 2 3 4 5 6 7 8 9 10 YEARS OF AGE Figure 128. Farly life history and life cycle of halibut, Hippoglossus stenolepis (from Thompson and Van Cleve 1936, Bell ard St. Pierre 1970, Forrester and Alderdice 1973). coe 165° 160° 155° 150° 145° 140° 135° 130° ALASKA 160° 60° 17 CH 9380 Al | 405 PK 79 PK + 10580 Al,Fl | 408SO FI ie 58° = Re | * 118 CH BRISITOL 2” 9 » AI,E! BAY «< g 757431 PK 68 CH 189CH A2,B1,D! r Al,B2,D3,El) }20 pK AI,BI,El_ | 327PK 02, E! ge? '79SO0 A2 | 254 SO A2,BI,FI | 170 so BI,F2 56° 63CH BI 21 PK 163 PK A2,03,E3 | 486 PK DI,E2 689 PK > ) 59SO Al 448S0 A8,Bl 361SO Al | 83 SO od U I5CH 52 PK 2PK 16 SO Al CH = Chum A = South Peninsula PK = Pink B = Kodiak I. 36 CH 1 SO = Sockeye D = Kodiak I.-Gulf Coast 52 PK 10 E = Kodiak I.-Shelikof Coast |/46s0 8 1 _Jaoe F = Chignik "361 SO Al" indicates that of 361 sockeve 12CH salmon tagged in this part of the North 59 PK Pacific, 1 was recaptured in the South 200 SO BI Peninsula District. 47 CH bal 118 PK BI,OI,EI 25 SO 168" 10! 155° 150° 145° 140° 135° 130° Figure 129. Tagged high seas salmon which spawned in the Western Gulf of Alaska, 1964-1965 (from Hartt et al. 1965, 1966). 309 Peninsula district where migratory stocks pass through the Shumagin Islands (Buck 1973). Few chinook were caught off the South Peninsula (Figure 130) in experimental fishing with gill net (Powell and Peterson 1957). Significant numbers of chinook appear off the South Peninsula between mid-June and late July with the peak run occuring in mid-July (Figure 131). In the Chignik district, the Chignik River is a significant spawning area for chinook (Figure 132). Most large commercial catches in this district are taken in Upper Chignik Lagoon and are probably Chignik River stock (International North Pacific Fisheries Commission 1961- 1970). Chinook arrive in numbers in the Chignik district during the entire month of July; the run peaks at midmonth (Figure 131). Three rivers of southwestern Kodiak Island have spawning populations of chinook: The Karluk River, the Ayakulik River (Red Lake), and the Frazer Lake drainage (Figure 132). The Frazer Lake population was established in 1966 following a four-year artificial stocking program. Adults returned for the first time in 1968, and more have returned each year since. Most of the significant commercial catches are recorded in the vicinity of the Karluk-Ayakulik River systems, although many are also taken all along Shelikof Strait (Alaska Department of Fish and Game 1973b). These Shelikof Strait fish are probably migrants bound for the Karluk-Ayakulik systems or Cook Inlet. Chinook arrive in numbers in early June, and are available to the salt water fishery through late July (Figure 131). Peak catches are normally taken between mid-June and mid-July. Large numbers of spawners have been counted in Karluk River by mid-August (Van Hulle and Murray 1973). Chinook females spawn an average of 5,000 eggs during August and September. Eggs incubate in stream gravel, overwintering to hatch the following spring. Young may migrate immediately to the ocean or spend as much as two years in fresh water. Normally they spend two to four years in the ocean before returning to spawn. In extreme cases, individuals may not return to spawn until eight years of age (Burner 1963). While they are in the ocean, chinooks feed upon herring and sand lance utilizing other small fish, crustaceans, and squid when available (Nanaimo Biological Station, undated). Coho Salmon According to commercial catch data coho salmon, Oncorhynchus kisutch, rank fourth in abundance among the five salmon species in the study area (Buck 1973). In the South Peninsula district, largest catches are made in the Shumagin Islands. These fish could be bound for Stepovak Bay spawning streams (Figure 133), but little is known of coho stock within this district. Cohos are present in large number from mid-July into September, with the peak run during the latter half of July (Figure 134). Figure 135 illustrates the offshore occurrence of coho salmon in the study area (Powell and Peterson 1957). OF SALMON ° 1-10 Figure 130. Distribution of chinook salmon in the offshore areas of the Western Gulf of Alaska during 1955 (from Powell and Peterson 1957). OTe PROBABILITY 10 os Os 04 02 0.0 10 os 06 0.4 0.0 10 08 06 0.4 02 0.0 L be Figure 131. 10 14 18 JUNE Timing of chinook saimor national 22 North 26 30 Paci fic 4 8 JULY Ficheries 12 16 20 commercial harvest Commis sior CHINOOK - KODIAK CHINOOK - CHIGNIK CHINOOK - SOUTH PENINSULA Probability catch will that the median 80% of the be taken during the season which includes this date. Probability that the midpoint of the season's catch will be taken during the period which includes this date. 24 28 | 5 9 13 I? 2i 25 AUGUST In the Western Guit of Alaska (trom Inte: 1961-1970) ut WR MAJOR SPAWNING DRAINAGE % ~~ SIGNIFICANT COMMERCIAL CATCH Figure 132. Significant chinook salmon spawning drainages and harvest locales in the Western Gulf of Alaska (from International North Pacific Fisheries Commission 1961-1970, Alaska Department of Fish and Game 1973b). zTe GBB MAJOR SPAWNING DRAINAGE % SIGNIFICANT COMMERCIAL CATCH Figure 133. Significant coho salmon spawning drainages and harvest locales in the Western Gulf of Alaska (from International North Pacific Fisheries Commission 1961-1970, Alaska Department of Fish and Game 1973b). ete 1.0 COHO—KODIAK as 06 04 0.2 0.0 ° COHO—CHIGNIK ° @ PROBABILITY ar) > on 2° iy fo} ° 1.0 COHO— SOUTH PENINSULA —— Probability that the median 80% of the catch will be taken during the season which includes this date. 0.8 06 Probability that the midpoint of the season's catch will be taken during the period which includes this date. 04 0.2 0.0 6 10 14 18 22 26 30 4 8 12 16 20 24 28 | 5 9 13 I7 21 25 29 JUNE . JULY AUGUST Figure 134. Timing of coho salmon commercial harvest in the Western Culf of Alaska (from Interna tional North Pacific Ficheries Commiocien 1961-1970) vie NUMBER OF SALMON e 0 ° 1-10 11-40 Figure 135. Distribution of coho salmon in the offshore areas of the Western Gulf of Alaska during 1955 (from Powell and Peterson 1957). ste 316 Commercial catch data indicates that Chignik district cohos are “most abundant in Upper Chignik Lagoon (International North Pacific Fisheries Commission 1961-1970). These fish are probably spawners of the Chignik River system. Cohos arrive in late July and are commercially harvested into September. Peak abundance occurs during the first half of August (Figure 134). In the Kodiak District, cohos spawn in streams which are concentrated in the northeast and southwest corners of Kodiak Island. A few signifi- cant spawning drainages are located on the west side of Shelikof Strait (Figure 132). Large commercial catches have been taken regularly in the vicinity of spawning drainages as well as around Afognak Island (International North Pacific Fisheries Commission 1961-1970). Cohos are taken from mid-June into mid-September with peak runs arriving in mid-August (Figure 134). Roelofs (1964) reported that cohos enter the Afognak Lake system in early August. Cohos were observed spawning in the Buskin and Karluk Rivers during October (Van Hulle and Murray 1972, 1973). Van Hulle and Murray (1972) recorded the main smolt outmigration from one Kodiak drainage between mid-June and mid-July (Figure 136). During autumn, cohos spawn an average of 3,500 eggs per female in freshwater streams. Eggs develop in the gravel, overwintering to hatch the following spring. Juvenile cohos spend one to two years in fresh water before outmigration to salt water. After an additional year or two in salt water, cohos return to spawn and die (Burner 1963). In the marine environment, cohos feed upon herring and sand lance, as well as other small fish, squid, and crustaceans (Nanaimo Biological Station, undated). Chum Salmon Chum Salmon, Onocorhynchus keta, spawn throughout the study area. According to commercial harvest data, chums are most abundant in the South Peninsula district (Buck 1973). Powell and Peterson (1957) show chums to be abundant offshore throughout the study area (Figure 137). Most chums in the South Peninsula district are caught along the south shore of Unimak Island or in bays northwest of the Shumagin Islands (International North Pacific Fisheries Commission 1961-1970). Major spawning systems are scattered throughout this district (Figure 138). Significant numbers of chums are present from mid-June to early August (Figure 139). Compared to the Kodiak and South Peninsula districts, the Chignik district produces small numbers of chums. Most are caught along the coast and bays northeast of Chignik, along the west side of Shelikof Strait. Several significant spawning systems are located here (Figure 138). Fish are present from early July through mid-August, with peak runs in late July (Figure 139). In the Kodiak district, chums spawn abundantly in drainages along the southeast coast of Kodiak Island. Smaller numbers spawn throughout the area and large commercial catches are widespread (Figure 138). This species is most abundant, according to commercial harvest data, number of fish 700 600 500 400 300 200 100 | 8 15 June Coho Salmon Smolt Coho Salmon Parr Coho Salmon Adults 22 29 Figure 6 136. 13 20 27 3 10 7 24 3I 7 July _ Aug ‘ Coho smolt and parr outm:gratien from Lake Cenevieve, Kodiak Island (from Van Hulle and Murray 4 Sept 1972. al 28 aig NUMBER OF SALMON e 0 ° 1-10 x 1-40 QO 41-100 Figure 137. Distribution of chum salmon in the offshore areas of the Western Gulf of Alaska during 1955 (from Powell and Peterson 1957). 8Te 7 MMM OMAUOR SPAWING DRAINAGE % ~~ SIGNIFICANT COMMERCIAL CATCH Figure 138. Significant chum salmoa spawning drainages and harvest locales in the Western Gulf of Alaska (from International North Pacific Fisheries Commission 1961-1970, Alaska Department of Fish and Game 1973b). 6TE 1.0 CHUM— KODIAK 0.8 0.6 0.4b | 0.2 ao 1.0 CHUM—CHIGNIK 0.8 > EF a 06 a < 8 0.4 «< a 0.2 a0 1.0 CHUM—SOUTH PENINSULA 08 Probability that the median 80% of the ° catch will be taken during the season which includes this date. 06 ——— Probability that the midpoint of the season's catch will be taken during the 0.4 period which includes this date. 0.2 0.0 1 ee ae 1 fo de 10 «614 18 22 26 3% 4 8 12 16 20 24 28 | 5 9 13 I7 2i 25 29 2 . JUNE JULY AUGUST Figure 139. Timing of chum salmon commercial harvest in the Western Gulf of Alaska (from Interna- tional North Pacific Fisheries Commission 1961-1970). 321 along the southeast coast of Kodiak Island and the west side of Shelikof Strait. Chums appear in early July and remain abundant into late August. Peak runs normally arrive during the last week in July and the first week in August (Figure 139). During autumn, chum salmon spawn in freshwater gravel averaging 3,000 eggs per female. Eggs develop in the gravel through the winter to hatch the following spring. Young chums move directly to salt water where they spend four years or less growing and maturing. At the end of this period, adults return to the coastal environment to spawn (Burner 1963). Chums feed primarily on small crustaceans (Nanaimo Biological Station 1967). Pink Salmon Pink salmon, Oncorhynchus gorbuscha, are abundant in the study area and may be caught in almost every bay or inlet along the coast during the spawning season. Powell and Peterson (1957) recorded pink salmon offshore throughout the study area (Figure 140). Pink salmon are harvested in quantity throughout the Shumagin Islands and in bays along the coast northwest of these islands (Interna- tional North Pacific Fisheries Commission 1961-1970). Spawning occurs in many small systems throughout this district (Figure 141). Pinks arrive in late June through early August with peak abundance in late July in the South Peninsula district (Figure 142). In the Chignik districk, pinks are most abundant along the coast and in the bays northeast of Chignik. In this area, many small spawning systems exist (Figure 141). Here they arrive in late July and are numerous through mid-August. Peak abundance occurs in late July (Figure 142). Kodiak district pinks spawn throughout the region and catches are widely distributed (Figure 141). Largest catches are regularly recorded from the southeast coast of Kodiak and in the Alitak Bay area. In recent even numbered years, Uganik Bay has produced large catches. Pinks arrive in number by mid-July and are abundant through mid-August. Peak catches are generally recorded the last week in July and the first week in August (Figure 142). Roelofs (1964), from observations at Afognak Lake, believed that most pink fry emigrated before early May, although small numbers were still observed in mid- May. Pink salmon spawn an average of 2,000 eggs per female during late summer in freshwater streams. Eggs develop in the gravel through the winter and move immediately into salt water where they spend the next one and one-half years. Pink salmon mature by two years of age and return. to spawn. Pink salmon feed primarily upon planktonic crustaceans while in salt water (Burner 1963). Sockeye Salmon Sockeye salmon, Oncorhynchus nerka, rank with pink salmon as the most abundant of the salmon species in the study area. Powell NUMBER OF SALMON e 0 Oo 1-10 11-40 Figure 140. Distribution of pink salmon in the offshore areas of the Westem Gulf of Alaska during 1955 (from Powell and Peterson 1957). ZZE 7 MMB MAJOR SPAWNING DRAINAGE * SIGNIFICANT COMMERCIAL CATCH U D a ee g . Ss } 8 ~~ 4 \ S Mino rl ged \ \ 0 J ?0 / nN ye Figure 141. Significant pink salmon spawning drainages and harvest locales in the Western Gulf of Alaska (from International North Pacific Fisheries Commission 1961-1970, Alaska Department of Fish and Game 1973b). €Ze PROBABILITY lo 14 18 Figure 142. PINK—KODIAK PINK— CHIGNIK PINK— SOUTH PENINSULA —— Probability that the median 80% of the catch will be taken during the season which includes this date. ——— Probability that the midpoint of the season's catch will be taken during the period which includes this date. 22 26 30 4 8 12 16 20 24 28 | 5 9 13 7 2i 25 29 2 JUNE JULY AUGUST Timing of pink salmon commercial harvest in the Western Gulf of Alaska (from Inter- national North Pacific Fisheries Commission 1961-1970). 325 and Peterson (1957) found sockeye at all offshore stations sampled in the study area (Figure 143). In the South Peninsula district, sockeye are most abundant along the south coast of Unimak Island (International North Pacific Fisheries Commission 1961-1970). The fish arrive in mid-June and are abundant into early July; the run peaks in late June (Figure 144). Few drainage systems support sockeye in this district (Figure 145). Most of these fish are probably migrants bound for other districts. The Chignik River supports a large run of sockeyes. Normally, large commercial catches are taken in Upper Chignik Lagoon on these stocks as they congregate before ascending the river to spawn. Fish appear in mid-June and remain abundant into early August (Figure 144). Two separate runs occur within this system. An early run in June is primarily bound for Black Lake, while a later run in July and August spawns in the Chignik Lake drainage (Burgner et al. 1969). In the Kodiak district, sockeyes spawn abundantly in several systems on the southwest coast of Kodiak Island and on the west side of Shelikof Strait (Figure 145). Usually the largest commercial catches are taken in the vicinity of the southwestern Kodiak spawning drainages. Spawning escapement may extend over a two to four month period in the Karluk River system (Burgner et al. 1969). Sockeyes normally become abundant in mid-June and are numerous through late August. No regular peak is evident in catches within this district (Figure 144). Sockeyes spawn between 2,000 and 4,000 eggs per female, depending upon size, in freshwater streams and lakes during late summer or early autumn (Hartman and Conkle 1961). Eggs develop in the gravel substrate through the winter to hatch the following spring. Young sockeyes migrate to lakes within the river system soon after hatching. The timing of this migration to Karluk Lake may vary from April to July depending upon when the initial spawning occurred (Hartman et al. 1967). Juveniles may spend up to three years in fresh water before they migrate to salt water. This normally occurred from late June through mid-July in one system on Kodiak Island (Figure 146). In Afognak Lake, peak emigration took place between May 27 and June 10 in 1963 (Roelofs 1964). Mature adults return to spawn after one to four years in salt water to complete the cycle. Sockeyes feed primarily upon planktonic crustaceans during their marine life (Burner 1963). Trout and char Two species of this group utilize the coastal marine environment of the Western Gulf of Alaska for a portion of their life cycle. Dolly Varden, Savelinus malma, abound in almost all freshwater systems within the study area with portions of many populations being anadromous. Steelhead trout, Salmo gairdneri, are not as widely distributed as the Dolly Varden char, but are more sought after by sport fishermen. NUMBER OF SALMON B 0 ° 1-10 x 11-40 41-100 Figure 143. Distribution of sockeye salmon in the offshore areas of the Western Gulf of Alaska during 1955 (from Powell and Peterson 1957). 9ze PROBABILITY SOCKEYE —- KODIAK 10 14 18 JUNE 22 26 30 4 8 12 16 20 24 JULY Timing cf sockeye salmon commereci: Gulf of Alacka (f1om International Commission, 1961-1970). 28 ] SOCKEYE —- CHIGNIK SOCKEYE —- SOUTH PENINSULA I 5 9 13 7 2i 25 29 2 harvect int th Pacific Probability that the median 80% of the catch will be taken during the season which includes this date. Probability that the midpoint of the season's catch will be taken during the period which includes this date. AUGUST he Westerr Fisheries ctw? GMB MAUOR SPAWNING DRAINAGE % ~~ SIGNIFICANT COMMERCIAL CATCH Figure 145. Significant sockeye salmon spawning drainages and harvest locales in the Western Gulf of Alaska (from International North Pacific Fisheries Commission 1961-1970, Alaska Department of Fish and Game 1973b). 8ze number of fish 900 700 600 500 400 300 200 100 18 25 ! 8 5 22 29 6 13 20 27 3 10 7 24 31 7 4 al 28 May June July Aug Sept —"—=-—= Sockeye Smolt Sockeye Adult Figure 146. Sockeye sal: nc ~ Lake Genevieve, Kodiak I<Janc (from n smolt outmigri 6vwe 330 Mature, migrant Dolly Varden return to freshwater streams to spawn in late summer and early autumn. Van Hulle and Murray (1972) reported that char began arriving in mid-July and continued at least through mid-September (Figure 147). Roelofs (1964) first observed char entering the Afognak Lake system in late June during 1963. This migration reached its peak in mid-July. Spawning occurs in October and November when females, dependent on size, deposit 600 to 6,000 eggs in freshwater stream gravels. Eggs develop through the winter and young char emerge from the gravel in spring. Juvenile Dolly Varden remain in fresh water until their third or fourth year (Armstrong 1969). Juveniles outmigrate to the ocean in late spring and early summer. Van Hulle and Murray (1972, 1973) found that the main outmigration in the northern part of Kodiak Island occurred from mid-May to late June. Roelofs (1964) found that most Dolly Varden had emigrated from Afognak Lake prior to early May in 1963. Since Dolly Varden overwinter in freshwater lakes, a return migration each year in late summer and early autumn brings marine juveniles and ripening adult spawners back into freshwater. Maturity is usually reached in five to six years. After spawning in stream gravels, adults join migrating juveniles in lakes to spend the winter. When spring arrives, surviving fish outmigrate once more to the ocean. This pattern is repeated each year (Armstrong 1969). Armstrong (1969) doubted if more than half the Dolly Varden spawners survive to spawn a second time. The maximum age may be eight years for this species. Steelhead spawn in the Karluk and Ayakulik Rivers on Kodiak .Island and in the Chignik River on the Alaskan Peninsula (Figure 148). Undoubtedly, other migrant populations of steelhead exist within the study area, but are probably of minor importance. Powell and Peterson (1957) found steelhead widely distributed offshore in the study area. In the Western Gulf, mature steelhead return from the ocean and enter freshwater streams to spawn in late summer and early autumn. Depending upon the size of the female, 200 to 8,000 eggs are deposited in the stream gravels in late winter or early spring (Paddock 1971). Steelhead overwinter in large freshwater lakes. Although steelhead may spawn in successive years, repeat spawners are comparatively few. Van Hulle and Murray (1972) reported only 23 percent of the Karluk River steelhead were repeat spawners in the spring of 1972. Depending upon water temperature, young steelhead emerge from gravels in mid to late summer. Juvenile steelhead may remain in fresh water two to three years before migrating to the ocean. Peak outmigration normally occurs in late spring and early summer, although individual fish may enter the ocean at almost any season. Most Alaskan steelhead spend one to two years in the ocean before returning to spawn for the first time. Occasionally, individuals may spend three or (rarely) four years at sea prior to spawning. One steelhead exceeding eight years of age was reportedly taken offshore of the Shumagin Islands, but this was an extremely old individual (Sheppard 1972) number of fish 800 700 600 500 400 300 200 100 June Outmigrant Dolly Varden Inmigrant Dolly Varden Figure 140. Dolly Varden char migration - Lake Genevieve, Kodiak Island (from Van Hulle and Murrav 1972). ref MB MAJOR SPANNING DRAINAGE Figure 148. Significant steelhead spawning drainages in the Western Gulf of Alaska (from Alaska Department of Fish and Game 1973b; Van Hulle and Murray 1972, 1973). Zee 333 Waterbirds The international bird resource is well represented in the Western Gulf of Alaska. Many migrate from country to country, crossing invisible boundaries through the Arctic. Others, adapted to high latitude summers, migrate each year between the northern and southern hemispheres (Shuntov 1964). Millions of ducks and geese breed in or pass through the Western Gulf of Alaska on their way to wintering grounds along the Pacific flyway. The ability of this area to supply the needs of these vast numbers of waterfowl directly affects the recreation and sport potential of the entire Pacific coastal area (U.S. Department of the Interior 1964). Diversity is limited to less than 150 species, the majority of which migrate south for the winter (Table 38). Birds of a single species often number more than a million. Passerines are not well represented, possibly due to the cold and the general lack of trees. Water-loving birds abound, especially the seabird and shorebird species. Some species of ducks and geese occur in the area in the hundreds of thousands, notably black brant, Branta nigricans and emperor geese B. leucopareia. Although both breed further north, they concentrate along the north coast of the Peninsula in the fall, then migrate west and south. The world population of emperor geese winter in the Aleutians and the southwest Gulf of Alaska, where they frequent coastal lagoons and bays. Here they feed along the beaches, predominantly on algae, kelp, and green shoots of Elymus and Equisetum (Murie 1959), as well as ripe eelgrass seeds. Although there is a small, resident population in Siberia, almost the entire world population of about 100,000 inhabit Alaska at some time (Bartonek et al. 1971). The black brant population of the Pacific flyway is often character- ized as staging entirely in Izembek Lagoon and then leaving en mass. Actually, although brant concentrate in the lagoon, they may be found in many places along the coast of the Peninsula feeding on eelgrass seeds, a highly nutritious and critical food source. A cold wind from the north in late October or November usually signals the fall departure of black brant (Jones 1972). Most of the geese then leave for the Pacific states, but small groups overwinter in the Shumagin and Simeonof Islands. Thousands of ducks also migrate through the area; the pintail, Anas acuta, is the most common (U.S. Department of the Interior 1973). Mallards, Anas platyrhynchos, and green-winged teal, Anas crecca carolinensis, are the most widely distributed resident dabbling ducks. Both species nest inland, but winter in lagoons and bays along the coast, feeding on mollusks and small crustaceans. Table 38. Bird Check List for Kodiak Island and Izembek National Wildlife Range (from Bartonek and Sowl 1972; U.S. Department of the Interior 1965, 1973). SPECIES Common Loon Yellow Billed Loon Arctic Loon Red-Throated Loon Red Necked Grebe Horned Grebe Short Tailed Albatross Black-Foot Albatross Laysan Albatross Fulmar Sooty Shearwater Slender-Bld Shearwater Fork-Tailed Petrel Leach's Petrel Double-Crstd Cormorant Pelagic Cormorant Red-Faced Cormorant Great Blue Heron Whistling Swan Trumpeter Swan White-Fronted Goose Emperor Goose KODIAK PR-c WV-c PR-c SR-c AV-r SR-o SR-c SR-a TV-r SR-u WR-o WR-u PR-u PR-u WR-u AV-r AV-r TV-u, PR-u TV-c, WR-c 334 SPECIES Lesser Goose Cackling Canada Goose Dusky Canada Goose Black Brant Mallard Pintail Gadwall Green-Winged Teal American Widgeon Short-Bld Dowitcher Long-Billed Dowitcher Western Sandpiper Hudsonian Godwit Bar-Tailed Godwit Sanderling Red Phalarope Northern Phalarope Pomarine Jaeger Parasitic Jaeger Long-Tailed Jaeger Glaucous Gull Glaucous-Winged Gull Herring Gull Mew Gull Table 38. (continued) KODIAK WR-o TV-o TV-o TV-u PR-c PR-c PR-c PR-u PR-c SR-c TV-c SR-u PR-a PR-u SR-c IZEMBEK N.W.R. TV-c, WR-c TV-r SR-c, WR-u TV-r TV-r TV-r TV-c, WR-u TV-r WR-u TV-c TV-c, SR-c AV-r TV-r, WR-r PR-c SR-u, WR-r 335 SPECIES Bonaparte's Gull Black-Legged Kittiwake Sabine's Gull Arctic Tern Aleutian Tern Common Murre Thick-Billed Murre Pigeon Gullemot Marbled Murrelet Kittlitz's Murrelet Ancient Murrelet Cassin's Auklet Parakeet Auklet Crested Auklet Horned Puffin Tufted Puffin STATUS PR- Permanent Resident SR- Summer Resident WV- Winter Visitor SV- Summer Visitor TV- Transient Visitor AV- Accidental Visdtat WR- Winter Resident Table 38. (continued) nat 2-/T 1-VA 1-82 t-VA .t-VT qq KODIAK SR-c PR-c PR-u PR-u WR-u WR-u PR-a SR-c SR-c ABUNDANCE a- abundant c- common u- uncommon o- occasional r- rare IZEMBEK N.W.R. AV-r TV-c, SR-c TV-r SR-c SR-c PR-u AV-r PR-u PR-u AV-r, SR-r PR-u AV-r SR-r PR-r gnilysbrse sqotsisnd bel eqotslsdd rmrodsro“ ‘agasl anitsmod rogosl oitiests4 tegosl bolisT-ynod Ifud evoouslo o begntW-zuoous lo [iv0 gaitroH Ifuod wom 336 337 Many diving and sea ducks also reside in the area. These ducks feed primarily on aquatic fauna (Table 39). Consequently, they have a stronger flavor than "grazing" ducks and are little utilized for food. Some northern countries have created small industries based on the down which eider duck use to line their nests. Gaviidae-Loons Of the four Alaskan loon species, three occur regularly in the study area: The Arctic loon, Gavia arctica; the common loon, G. immer, and the red-throated loon, G. stellata. The yellow-billed loon, G. adamsii, sometimes occurs as a straggler (U.S. Department of the Interior 1973). The common loon is a permanent resident of the Gulf. Loons nest on inland lakes, but winter along the coast. Using their feet to propel themselves, they can dive to depths of 60 meters in pursuit of their principal food--small fish (Table 40). Because their feet are so welladapted for diving, loons are extremely awkward on land (Peterson 1961). Podicipedidae-Grebes Both the red-necked grebe, Podiceps grisegena, and the horned grebe, P. auritus, are found in the study area in summer, but only the red-necked grebe is a permanent resident. Like the loon, grebes nest inland on ponds or lakes. They build nests of rotting vegetation which decays and releases heat and may aid egg incubation (Murie 1959). Except when nesting, grebes inhabit the inshore zone. They are capable of partially submerging, and frequently resemble small periscopes (Gabrielson and Lincoln 1959). Diomedeidae-Albatross Never abundant, three species of albatross are found in this part of the North Pacific during the summer: The black-footed albatross, Diomedea nigripes; the Laysan albatross, D. immutabilis, and the short- tailed albatross, D. albatrus. The latter was believed to be headed for extinction after Japanese feather hunters had slaughtered some five million birds on their main breeding grounds by 1903. In 1939 the volcano on the breeding island erupted, further decimating the population to less than 100. Recent sightings confirm the bird's continued existence and the population appears to be increasing (Sanger 1972b). Albatross have become notorious ship-followers (McHugh, 1955), scavenging anything on the ocean surface. Albatross found in the Western Gulf breed in winter, and normally range as far north as Alaska o S a Scaup Goldeneye Bufflehead Oidsquaw Harlequin Steller eider Common eider King eider Spectacled eider White wing scoter Common scoter Surf scoter Source: Pondweeds we wo oO Table plant & Misc. i N 14 10 1.5 10 16 39. Food Habits of Diving Ducks Percentage of Total Diet Molluscs w © ew Oo 16 16 25 19 82 46 42 75 65 61 Insects “ 28 41 11 10 13 32 10 s Crustaceans 32 17 48 57 45 19 13 17 10 Cottam and Knappen 1939, Cottam n oO 7 s 8 n n Po Pet a = 3 1 4 1 10 3 2.5 4 2 8 5 25 2 2 3 3 3 4 1939. animal 338 Table 40. Feeding Methods and Foods of Sea Birds n © : oo Pr Y SG 0D s » co od S H o eG H od oO 1) ao od o ob a SG bo oO un N v S dd oA Ss r vv d oa 3 > os dl n n my q GROUP oi 8 8 23 3 3 3 8 $ a & oo oo w o a o Ss ~~ Pv oo od oO o co Ss v r GH fo} Vv di & s > S H v 8 S od od od E a s ° oa) uO a ov i) oO o i} 5 5 ° rR Oo r wu od 4 6 Qa vp WH H > ¢ n n v a <a <= n oe H a H a v & H wo = & & r Ob nO a Dp a & S od ft x 5 3 v9 a 5 5 o al ot o H oa s =x a a a n wn wn a a a a =a ah Uv oO cS 0 Diomedea oP 0 0? ~ o 0 ° . ° Pterodroma P -+ o+ ° O+ . 0 ° . ° Puffinus oP : ° + 0 o+ ° 0 0 oO . ° Oceanodroma OP ° oO ? ° ° + 0 + Phalaropus LOP 0 : 0 ° Stercorariu LOP o* oc . ° 0 7 + : Larus LCO ° ° ° ° ° ° . ° ° Larus "Rissa" COP 0 o+ o+ 0 7 oO -+ Larus 'Xema'' LOP 0 ? 0 ° 0 ? 0 ? . Sterna LCOp ° 0 0 o+ . Alca and Uria Op 0 c ° : Cepphus Co ° 0 0 0 ° Brachyramphus c 0? 0 o+ 0 ° Synthliboramphus COP ? 0 7 ° o+ Oo Cyclorrhynchus 0 0 * 0 3 Aethia co 0 0 + Cerorhinca cO 0 ° 0 0 Fratercula and Lunda COP 0 0 ° ° Habitat; L, land; some or all species feed in terrestrial or freshwater environments for at least part of the year; the feed- ing methods used and food obtained by these species (or at these times) are not considered in the table. C, coastal; 0, off- shore; P, pelagic. Lower case indicates that a habitat is used relatively little. Feeding methods. Plunging is surface plunging except where specified. Pursuit diving is primarily wing-propelled except where specified. Symbols. 0, feeding method or food group of major importance; o, of minor importance; +, indicates that importance may be underestimated, or is certainly greater in some species. Source: N. P. Ashmole. 1971. Sea Bird Ecology and the Marine Environment. 6g¢ 340 only in summer. Kuroda (1960a) theorized that squid, the albatross! main food, are too large in the northern latitudes to be eaten by the end of summer (Table 40). Nakamura (1963) could find no evidence of the correlation between water temperatures and numbers of albatross, which Kuroda (1955, 1960b) found previously. Albatross wings are aerodynamically ideal for floating on seabreezes, and although albatross are sometimes found feeding in tide rips, they usually feed far from shore (Sanger 1972b). Procellaridae-Shearwaters, Fulmars, and Petrels Those species of Procellaridae which occur in the study area include the sooty shearwater, Puffinus griseus; the short-tailed shearwater, P. teniurostris; the scaled petrel, Pterodroma inexpectata; the Pacific fulmar, Fulmarus glacialis; and possibly the pale-footed shearwater, Puffinus carneipe carneipes. The fulmar is the only member of this family which breeds in the Western Gulf. There is at least one colony of almost 400,000 in the Semidi Islands (Figure 149 and Table 41), and strong circumstantial evidence indicates a colony somewhere off of Afognak Island, since many birds are observed in Shelikof and Marmot Straits. The other species breed in the southern hemisphere where their colonies are of some economic importance. Coastal-dwelling Australians and New Zealanders supplement their diets with young shearwaters, colloquially called muttonbirds (Falla et al. 1966). Serventy (1967) presented a discussion of the ecology of the short-tailed shearwater in the South Pacific. Procellaridae often feed together. Arnold (1948) estimated 38,000 fulmars and 160,000 shearwaters feeding in a tide rip in Isanotski Straits. They were feeding on a reddish-orange marine organism. The organic contents of 10 shearwater stomachs obtained in Alaska included: amphipods, 13 percent; schizopods, 15 percent; undetermined crustaceans, 20.8 percent; squid, Loligo sp., 16.1 percent; undetermined marine invertebrate flesh (possibly squid), 29.4 percent; and fish, 5.7 percent (Cottam and Knappen 1939). Sanger (1972a) reported squid, fish, and plankton to be the most frequently cited food items (Table 40). These are taken at or near the surface, although Sanger personally observed P. teniurostris and P. griseus caught in salmon nets at depths of one to two meters. Fisher (1952), in his book The Fulmar, gave a detailed description of the biology of these birds. In the early days of whaling fulmars developed the scavenging habit. Fisher theorized that fulmars are ex- panding their range by following ships south. The fulmar's yearly cycle seems to be almost identical throughout its range. Egg-laying begins in early May, and the last eggs hatch in July. By September lLeroy Sowl, Supervisory Fish and Wildlife Biologist, U.S. Bureau of Sport Fisheries and Wildlife, Anchorage. Field notes compiled during special studies. 59° 58° 57° 56° — 55° 164° 162° 160° Figure 149. Seabird colonies de- scribed in literature (from Bartonek and Sow] 1972). ° 150° 158° 156° 154° 152 59° 58° 57° 56° 55° 54° Oo ° 158° 156° 154° 152! 150 +s 342 all the young are fledged. Young chicks feed on an oily secretion of the parent bird. This smelly substance can be accurately ejected by both parents and young to a distance of one to two meters. In other parts of the north where fulmar eggs and young are regularly harvested and sold, this oily secretion is a nuisance. Natives harvest eggs in the Alaskan Pribilofs. Hydrobatidae-Storm Petrels The two species found in the Western Gulf are the fork-tailed petrel, Oceanodroma furcata, and Leach's petrel, 0. leucorhoa. These nocturnal birds are known in literature as Mother Carey's Chickens. Their habit of following ships' lights has created a number of supersti- tions about them. One is that they presage storms, but actually they are attracted to the calm wake of a ship in heavy seas (Alexander 1954). Since storm petrels are burrowers and nocturnal, their colonies are difficult to observe. Murie (1959) speculated that the birds burrow in the Shumagin Islands. Both species nest in the Gulf, and egg-laying commences in May. By the end of August, most young are fledged and take to the ocean. The Leach's petrel migrates south for the winter, but the fork-tailed petrel is a year-round resident. When feeding, these birds fly very low over the water and patter with their feet to help maintain height (Alexander 1954) (Figure 150). This may create suction (Ashmole 1972). They feed on crustaceans, fish, and mollusks (Sanger 1972a) and are also attracted to oily substances on the water (Alexander 1954). Phalacrocoracidae-Cormorants The pelagic, Phalacrocorax pelagicus; red-faced, P. urile; and double-crested, P. auritus, cormorants all nest in cliffs in the Western Gulf area (Table 41). The double-crested cormorant, however, is very adaptable and also nests on flat islands (Murie 1959). The pelagic is common throughout the area, but the double-crested cormorant is rare (U.S. Department of the Interior 1973 and 1965). The red-faced cormorant nests from the Shumagin Islands west along the Aleutian Chain (American Ornithologists' Union 1957). Cormorants nest in small colonies and lay two to six bluish eggs on a carelessly assembled mass of vegetation, usually seaweed mixed with guano (Alexander 1954). In the southern hemisphere this guano is economically important. Cormorants are expert divers, propelling themselves with their feet in pursuit of their principal prey, fish (Figure 150). There is some evidence that their hearing is acute enough to guide them in murky water (Alexander 1954). Cormorant plumage is much less dense ‘ than other sea birds, and its wetability may aid in diving. The feathers become so waterlogged that cormorants are often observed on posts or trees spreading their wings to dry. Cormorants are permanent residents in the Western Gulf. P attern9 i ydroplaning ) Figure 130. feeding method: Surface Filtering Scavenging > Surface plunging bird from Ashmcic ——~ —_ Deep plunging ywy Pursult diving = wings ky oe Table 41. Map refer- ence bo a 10 10 a Seabird colonies in The Western Gulf of Alaska identified in the literature (from U.S. Department of the Interior 1972). Namep lace Amagat I. Sanak Is. Bay Pt. Round I. Zachary Bay (islets) Delarof Harbor The Haystacks Bird I. Big Kiniuji I. Castle Rock Karpa I. Stepovak Bay Mitrofania I. Semidi Is. Aghiyuk I. Chowlet I. Alikserit 1. Semidi Islands Suklik I. Kuliktagik I. Anowik I. Kateekuk I. Aghik I. Species Horned puffin F-t. petrel Tufted puffin Leach's petrel Murres B-1. kittiwakes T-b. murres Tufted puffin Horned puffin Pib. gullemot B-1. kittiwakes Tufted puffin Horned puffin Pig. guillemot B-1. kittiwakes Murre B-1. kittiwakes Murre Tufted puffin Horned puffin B-1. kittiwake Murres Murres B-1. kittiwakes Tufted puffin Tufted puffin Murres Fulmars B-1. kittiwake Tufted puffin Horned puffin Pig. guillemot Fulmar Murre Tufted puffin Horned puffin Pib. guillemot Fulmar Fulmar Fulmar Fulmar Fulmar B-1. kittiwake Numbers 15,000 Medium Very large Very large Some Some Millions Great numbers Great numbers 344 Map refer- ence 14 15 16 17 18 19 20 21 22 24 25 26 27 28 29 30 31 Table 41. (continued) Nameplace Atkulik I. Cape Kuyuyukak Amalik Bay Puale Bay Sea Lion Rocks Sea Otter I. Uganik Bay Kashvik Bay Uganik Passage Kukak Bay Kukak Point Yugnak Rocks Spiridon Bay Chief Pt. Ditto Is. Ayakulik Uyak Bay Deadman Bay Fiat Island Cape Kiavak Sitkalidak Strait Avnulu Creek John I. Cathederal I. Species Numbers B-1. kittiwake Murre B-1. kittiwake Murre B-1. kittiwake Tufted puffin Cormorants Tufted puffin Cormorants Fulmars Fulmars Puffins G-2. gull Cormorant Few Pig. gullemot Puffins G-2. gull Horned puffin 100 D-c. cormorant 8 pr. Pelag. cormorant 80 pr. R-£. cormorant 10 pr. G-w. gull Horned puffin Tufted puffin Puffins G-w. gull B-1. kittiwake B-1. kittiwake G-w. gulls Cormorants B-i. kittiwake 10,000* Puffins Cormorants Tufted puffin Cormorants B-1. kittiwakes G-w. gulls Tufted Puffin B-1. kittiwake Tufted puffin Cormorants B-1. kittiwake Tufted puffin G-w. gull Cormorants 345 Map refer- ence 39 40 41 43 44 45 Table 41. Nameplace Midway Bay Ghost Rocks Ladder I. Boulder Bay Gull Point Svitiak I. Utesisto I. Middle Bay Viesoki I. T. S. Inter Zamka I. Cliff I. Puffin I. Chiniak I. Parrot I. Taliudek I. Foul Bay Peril Cape Izhut Bay Edge. Mountain Big Waterfowl Bay Whale I. Anton Larsen Bay (continued) Species G-w. gull Mew gull Arctic tern Cormorants Tufted puffin G-w. gull B-1. kittiwake B-1. kittiwake G-w. gull Tufted puffin B-1. kittiwake Tufted puffin G-w. gull Tufted puffin B-1. kittiwake G-w. gull Tufted puffin B-1,. kittiwake Cormorants Tufted puffin G-w. gull] Cormorants Tufted puffin G-w. gull Cormorants Tufted puffin B-1. kittiwakes Tufted puffin Pig. guillemot Tufted puffin Cormorant G-w. gull C. murre B-1. kittiwake Pig. guillemot Cormorants Puffins Cormorants B-1. kittiwake Cormorants Puffin Pig. guillemot B-1. kittiwake B-1. kittiwake G-w. gull Puffins Numbers 100 ,000* 100,000 100,000 346 Map refer- ence 46 47 49 50 51 52 53 Nameplace Sharatin Bay Kekur Point Bare I. Shakun Rocks Augustine I. Chisik I. Duck I. Tuxedni Bay Gull Island Glacier Spit East Amatul: (Barren Is.) Nord I. (Barren Is.) Elizabeth I. Table 41. (continued) Species B-1. kittiwake G-w. gull Puffins B-1. kittiwake G-w. gull Puffins B-1. kittiwake G-w. gull Tufted puffins Horned puffins B-1. kittiwakes D-c. cormorant Pelag. cormorant G-w. gull Pig. guillemot Common murre Horned puffin Tufted puffin B-1. kittiwakes Common murre Horned puffin Tufted puffin B-1. kittiwake B-1. kittiwake Murres Pig. guillemot Horned puffin Tufted puffin Cormorants Cormorants G-w. gull B-1. kittiwake Murres Puffins B-1. kittiwake Murres Puffins Cormorants B-1. kittiwake Numbers Abundant (25,000) Common Fairly common Common Common Abundant Common Fairly common Large colony Abundant Common Fairly common Large colony Many Many Many 100,000 100,000 (5,000) 347 348 Haematopodidae-Oystercatchers The black oystercatcher, Haematopus bachmani, is a permanent resident in the Western Gulf, inhabiting the rocks along the shore. Its primitive nest is merely beach rocks or perhaps a depression in a rock, where two to three eggs are laid in late spring (Peterson 1961). The family unit probably lasts at least into fall. Although their bills are adapted for opening mollusk shells, the technique must be taught to the young.1 Oystercatchers forage for bivalves, oysters, crabs, and marine worms below the high tide mark (Peterson 1961). They blend into their habitat so well that they are seldom seen, but they are common on the southern side of the Peninsula and on Kodiak Island (U.S. Department of the Interior 1965 and 1973). Charadriidae and Scolopacidae-other shorebirds These birds have been grouped together since little work has been done on them in this area. Generally, they feed on insects, crustaceans, mollusks, worms, and invertebrates in tidal flats and marshes. Many of these birds breed in the study area or migrate through from the north, but occur only rarely in winter (Jacques 1930). Phalaropidae-Phalaropes Two species of phalarope nest in the Western Gulf, the red phalarope, Phala fulicarius, and the northern phalarope, Lobipes lobatus. Although Phalaropes are classed as a shorebird, they are usually found on the oceans, spinning and bobbing for plankton and marine invertebrates (Peterson 1961) (Figure 150). This bird is unique because the female is larger and gaudier than the male and does the courting, while the male builds the nest and incubates the eggs (Alexander 1954). Stercoraridae-Jaegers The pomarine, Stercorarius pomarinus, parasitic, S. parasiticus, and long-tailed, S. longicaudus, jaegers all occur in the Western Gulf. Jaegers are both predatory and parasitic, forcing other birds, especially the Larids, to disgorge recently eaten fish (Sanger 1972a) (Figure 150). When this food source is not available they feed on small mammals, insects, and eggs and young of other birds. Carrion or refuse on the water surface is also eaten (Alexander 1954). LNikko Tinbergen, Consultant. Special television program on oyster- catchers, ''The Specialist." Time-Life Films , Inc. New York, N.Y. 349 Jaegers are not colonial nesters, but often seem so since they are attracted to the true colonial birds (Belopolskii 1957) (Figure 149). Jaegers nest in a hollow in the ground, where the female lays two to three eggs in June (Alexander 1954). When not breeding, they feed farther offshore than the Larids. Jaegers spend the winter along the Pacific coast south of the study area. Laridae-Gulls and terns These colonial nesters are common to abundant throughout the Western Gulf of Alaska (Table 40). The commonest species are the glaucous-winged gull, Larus glaucescens, and the black-legged kittiwake, Rissa tridactyla, both permanent residents of the study area. The glaucous-winged gull shares the predatory and parasitic instincts of the jaeger, but spends more time on land. Belopolskii (1957) in his comprehensive book on sea bird colonies in the Barents Sea, examined 25 glaucous gull, L. hyperboreus, stomachs which contained 36 percent adult murres, 32 percent nestlings and eggs, 8 percent kittiwake young and eggs, 12 percent eider young and eggs, and 20 percent lemmings. Belopolskii thought that gulls normally preferred fish, switching to other food sources when fish are scarce (Table 40). The glaucous gulls he observed preferred to force kittiwakes to disgorge rather than fish themselves. In Alaska, gulls commonly harass brown bear for salmon. Pearson (1968) observed the diet of the lesser black-backed gull, Larus fuscus, in the Farne Islands, to be 75 percent fish, while kittiwake and tern diets were nearly 100 percent fish. Belopolskii (1957) noted that when fish are scarce, birds specifically adapted for fishing such as murres, take all the available fish. Kittiwakes then turn to crustaceans and other less concentrated food, which results in a smaller clutch size. Two terns are summer residents of the area, the Arctic tern, Sterna paradisea, and the Aleutian tern, S. aleutica. Both birds are common colonial nesters in the area. Although the Aleutian tern formerly nested on Kodiak Island, it is now believed to breed only on the Alaska Peninsula and associated islands (American Ornithologists' Union 1957). Belopolskii (1957) noted that in the Barents Sea, eiders, which are not a colonial nester, frequently appear to nest in colonies on the rim of tern colonies. He theorized that the masses of terns served as protection for the eider broods. In winter, these birds both migrate out of the study area. The Aleutian tern migrates to the southwest and is frequently found on Japanese islands (American Ornithologists' Union 1957). The Arctic tern makes one of the most arduous migrations known, flying south as far as the edge of the Antarctic ice pack, a distance of almost 20,000 kilometers (Orr 1970). 350 Alcidae-Auks, Murres, Puffins There are a number of references on this unique bird family but except where noted, the following discussion will be based largely on Kozlova's observations in Russia (Kozlova 1957). Two murre species reside in the Western Gulf, the common, Uria aalge, and the thick-billed, U. lomvia. They are difficult to distinguish without examination, and are often found in the same flock (Murie 1959). Murres are specialized for fishing and pursue their prey underwater. In Russia their spring diet consists largely of capelins and cod with 10 percent crustaceans. In summer the diet is virtually all fish, predominantly herring. Belopolskii (1957) felt that these seasonal differences are due to availability rather than seasonal preferences. Murres are exclusively colonial nesters (Table 41). Sowl! estimated that the colony at Cape Unalishagvak contained 275,000 birds. These colonies are located on cliff plateaus and ledges which can be approached from the sea. Murres are unable to take off from level ground. Murres are so adapted to colonial nesting that they have lost their nest-building instinct. Their eggs are laid on bare rock, and often collect in crevices. If a murre parent returns and its eggs are gone, it gets an egg from the nearest crevice. According to Belopolskii (1957), the least dominant murres are pushed to the outer edge of the colonies where predation from gulls and jaegers occurs most frequently. The dominant birds in the flock are most likely to reproduce, protected by sheer numbers of birds. Belopolskii felt that the eggs themselves are well-adapted to colonies. They are extremely tough and can withstand rolling and falling which other eggs cannot. The pointed end of the egg helps maintain position on the ledge, and at the end of incubation, the center of gravity shifts to the pointed end. This is adaptively critical, as murres probably would not have time to start over if the eggs were destroyed near the end of incubation. Murre eggs are large and nutritious and are often harvested in other areas of the world. Murres are most at home on the open ocean where they winter and also find refuge during severe storms. Occasionally, a massive die- off occurs following winter storms (Bailey and Davenport 1972). The pigeon guillemot, Cepphus columba, is a permanent resident in the Western Gulf. On the Pribilofs, their diet was found to consist of 56.8 percent amphipods, 20.8 percent crabs, 17.2 percent isopods and 4 percent fish. These birds feed just below the surface of the water, frequently dipping their heads into the water or even swimming with the head completely submerged. They nest in pairs at the top of cliffs, just above the tide or in caves along the coast, but never lLeroy Sowl, Supervisory Fish and Wildlife Biologist, U.S. Bureau of Sport Fisheries and Wildlife, Anchorage. Field notes compiled during special studies. 351 without shade (Drent 1965). The guillemots are not as specialized as other alcids, and can nest inland because of their flight maneuverability and their ability to take off from land. Three murrelets, the marbled, Brachyramphus marmorata; Kittlitz's murrelet, B. brevirostra; and the ancient murrelet, Synthliboramphus antiquum, all nest in the study area. The marbled and ancient murrelets are permanent residents. The ancient murrelet is nocturnal and feeds on marine invertebrates in the upper water layers. It dives infrequently. This murrelet frequents shallow marine waters in summer, but in winter does not enter semi-closed areas such as bays or inlets. They nest in abandoned puffin burrows or dig their own about one-half meter long and lined with grass. Both parents brood steadily and can be seized on the nest. The young leave the nest at night, long before they can fly. The marbled and Kittlitz's murrelets are believed to nest far from land in tundra and rock slides. A Kittlitz's nest was recently discovered and photographed by Edgar Bailey at Cold Bay (Jones 1972). Both birds feed on small fish, mollusks, and crustaceans. The only auklet permanently residing in the study area is the abundant crested auklet, Aethia cristatella. Cassin's auklet, Ptychoramphus aleutica, is a rare winter resident. Both the parakeet, Cyclorrhyncus psittacula, and the least auklet, Aethia pusilla, are summer residents. Crested auklets gather in large flocks to feed on small crustaceans and polychaetes just below the water surface (Figure 150). They are very active birds and spend much time in flight or running along the rocks, especially at sunset when they leave the nesting area. They nest in cliffs and rocks, in crevices, or between stones. The young are fed on small crustaceans which are carried in a neck pouch that Aethis develop in the breeding season. The crested auklet nests east to the Shumagin Islands, wintering in the same area (American Ornithologists' Union 1954). It is not well adapted to migrating and is very susceptible to severe winters. The crested auklet is nocturnal only during the breeding season (Alexander 1954). The least auklet resembles the crested and often feeds with it (Bedard 1968). In some areas of the world these auklets are relished for food and trapped with nets by the natives. Two puffins are common summer residents in the study area, the horned puffin, Fratercula corniculata, and the tufted puffin, Lunda cirrhata. Part of both populations overwinters here. The tufted puffin, endemic to this region, has a distribution which strikingly parallels that of the northern sea lion, Eumetopias jubata (Uduardy 1963). These puffins frequently nest together in burrows which they dig with their powerful hind feet. The horned puffin generally digs 352 two entrances to his burrow. Puffins feed largely on fish, supplemented by crustaceans, mollusks, and other invertebrates. Their wings are specialized for swimming underwater (Figure 150), but consequently they lack flight maneuverability. The size of puffin colonies is difficult to estimate, but Sow14 observed colonies of several hundred thousand. In some parts of the world, the tufted puffin is gathered by natives holding nets which the puffins can't avoid since they lack maneuverability. The meat and fat are used for food, and the skins made into parkas. Marine Mammals Marine mammals were almost solely responsible for the early develop- ment of Alaska. George Wilhelm Steller of the Bering expedition first described the fur seal, Callorhinus ursinus, and the sea otter, Enhydra lutris, after being shipwrecked in 1741 on the Commander Islands (Kenyon 1969). The Russians established many colonies in the Western Gulf and the Aleutians to serve as stations for the hunters. Scammon (1874) described the days of the great Nantucket whalers, enticed to Alaska by the right whale, Balaena glacialis. As late as 1970, the fur seal, harbor seal, Phoca vitulina, and Steller sea lion, Eumetopias jubata, harvests in Alaska were estimated at a combined value of more than three million dollars (Kenyon 1971). Except for subsistence use by certain Alaskan Natives, the Marine Mammal Protection Act of 1972 prohibits all harvest of marine mammals. An exception is made for the fur seal, which is regulated by international treaty. Enhydra lutris-the sea otter. Unless otherwise noted, a comprehensive summary by Karl Kenyon (1969) is used in the following discussion. The sea otter treaty was signed by Woodrow Wilson. Actually, fewer than 2,000 sea otters remained (Alaska Department of Fish and Game 1973a). Since the fur harvest was not regulated, no accurate records exist of the number of otter skins harvested prior to 1911. Lensink (1960) estimated that there were more than 900,000 animals harvested. Although sea otters can only be harvested by Natives at present, their pelts may be worth 280 dollars apiece. This figure is high because of the scarcity of pelts as well as their superior quality. If sea otters were harvested annually at the sustainable rate of 2 to 2.5 percent of their population, the pelts could become less valuable. Sea otters may be found in several favorable areas in the North Pacific, but they are especially abundant in the Western Gulf and along the Aleutian Islands (Figure 151). Kenyon conducted aerial lypid. 59° 58° 57° 56° 55° Figure 151. 164° 162° of Fish PRESENT CONCENTRATION Distribution and con- centration of sea otter (from Ali 160° ska Department ) and Game 19 NS oat. 158° 156° 158° 156° 150° 150° 58° 57° 56° 55° 54° £S 354 surveys of the principal otter colonies in Alaska from 1957 to 1965. Five of these colonies are located in the study area, including the Sanak Islands, Sandman Reefs, the Shumagin Islands, the central Alaska Peninsula, and Kodiak Island. The total population of the area was estimated at more than 20,000 otters. Schneider (1973) believed that aerial survey estimates were consistently lower than actual populations, and estimated the population in the same area to be between 27,000 and 35,000. Sea otters do not undergo seasonal migrations. When ice invades their habitat, as in the winter of 1971-1972, mortality is very high (Jones 1972). Although otters can maneuver on land, food is always consumed in the water. Their diet is largely composed of echinoderms and mollusks. Sea urchins, Echinoidea, are the most prevalent single item (Murie 1959). Sea otters are generally confined to coastal areas where the water is less than 75 meters in depth (Alaska Department of Fish and Game 1973a). Although kelp beds are frequently cited as a limiting factor, several colonies are located far from any kelp beds. Male otters prefer the exposed points along shore, while females congregate along the coast between these points. Otters give birth to a single pup only once every two years, but infant mortality is low. They are capable of rapid population expansion. Sea otters breed year-round, but the peak pupping season comes in spring (Alaska Department of Fish and Game 1973a). According to Kenyon, gestation takes about 13 months, due to delayed implantation (Figure 152). In severe winters when food is difficult to obtain, pups born in the fall often survive because they are small enough to nurse through the winter. Larger pups are often abandoned by females who cannot provide enough food for herself and her young. Sea otters depend on their dense fur to trap air for insulation. Fur is kept scrupulously clean, and any physical contamination of their water is not only dangerous, but in the case of oil, almost invariably fatal. Eumetopias jubata-the Steller sea lion Mathisen and Lopp (1963) stated that the Western Gulf area is the center of the world population of Steller sea lions. Of a total population between 240,000 and 300,000 (Kenyon and Rice 1961), as many as 60,000 are found in the study area (Mathisen and Lopp 1963). A map of rookeries and their estimated populations can be found in Table 42 and Figure 153. Generally, sea lions prefer rocky outcrops for their rookeries and resting places (Alaska Department of Fish and Game 1973a). PERCENT 100 90 80 TO 60 sO 40 20 10 Figure 152. IMPLANTED PREGNANCY KAAAANAAAN UNIMPLANTED PREGNANCY NOT PREGNANT MONTHS Phases in the reproductive cycle of the female sea otter (from Kenyon 1969). 355 Table 42. Ref. No. 178 179 180 181 182 190 191 192 192 200 201 205 206 207 208 209 210 215 216 217 218 219 220 235 236 237 238 239 240 241 245 246 250 251 252 253 255 256 257 258 259 265 266 267 268 Location Bird Island Sanak Island (South Rock) Cherni Island Clubbing Rocks Pinnacle Rock Nagai Island Twins Chernabura Island Simeonof Island Amak Island Sea Lion Rocks Wosnesenski Island Jude Island Shumagin Islands (Sea Lion Rocks) Unga Island (Unga Cape) The Whaleback The Haystacks Atkins Island Castle Rocks Kupreanof Peninsula (Kupreanof Point) Spitz Island Mitrofania Island Seal Cape Atkulik Island Atkulik Island Sutwik Island (West end) Sutwik Island (Foggy Cape) Cape Kumlik Ugaiushak Island Chowiet Island Chirikof Island Sundstrom Island Sitkinak Island (Cape Sitkinak) Twoheaded Island Cape Hepburn Bert Point Cape Barnabas Ugak Island Chiniak Island Long Island (Vera Bay Rocks) Cape Ugat Puale Bay (Rocks at entrance) Outer Seal Rocks Tombstone Rocks Middle Cape Steller Sea Lion Rookeries and Hauling Grounds (from Alaska Department of Fish and Game 1973a). Population 260 3200 380 5600 980 15 10 2000 150 2000 350 300 3000 (Pups) 400 30 600 100 3100 400 35 700 216 10 100 10 738 Unknown 10 600 5000 500 100 470 3600 1900 440 600 50 2800 50 50 25 356 Ref. No. 315 316 317 320 321 322 323 324 325 326 327 328 329 410 Table 42. (continued) Location Population Cape Gull 100 Cape Ugyak 100 Takli Island (Rocks west of Island Unknown Marmot Island 10000 Afognak Island 100 (Tonki Cape) Afognak Island 50 (Cape Paramonof) Latax Rocks 3300 Cape Nukshak 500 Sugarloaf Island 10000 West Amatuli 1600 (Southeast end) Sealion Rocks 500 Ushagat Island 100 West Amatuli 100 (Rocks on west end) Augustine Rocks 500 357 59° 58° 57° 56° 55° 164° Figure 162° 160° Rookeries and hauling grounds of the Steiler Sea Lion (from Alaska Department of Fish and Game 1973a). 158° 156° 154° 152° 150° 150° 58° ST? 56° 55° 54° age The Steller sea lion does not make seasonal migrations. Some move north in late summer and early fall (Kenyon and Rice 1961). These bulls retreat when ice advances, but ice is not a restricting element. A small, permanent population remains on the Pribilof Islands, surrounded in winter by ice-infested seas (Kenyon 1962). These islands have supported as many as 15,000 sea lions, but intensive hunting almost exterminated them. With protection, the population has risen to about 6,000 animals (Kenyon 1962). Steller sea lions are territorial during summer (Alaska Department of Fish and Game 1973a). Their rookeries are generally large, averaging 1,000 animals in the Aleutians (Kenyon and Rice 1961). Most are born in June. Although they can swim at birth, they are very awkward. The bond between mother and pup may last more than a year, an unusually long time for any animal (Sandegrer 1970). Territories are abandoned at the end of summer. Males and females separate and disperse into scattered bays and estuaries along the coast (Alaska Department of Fish and Game 1973a). These sea lions are notorious because of their fondness for commercially important fish, especially salmon, halibut, and herring. There is a definite economic loss to fishermen because of gear damage and actual loss or damage of fish (Thorsteinson et al. 1961). Tikhomirov (1964) said that sea lions are often hauled up in crab tangle nets, which > indicates that crab is part of their diet. These nets are no longer legal in the United States. The diet of sea lions includes rockfish, sculpin, greenling, sand lance smelt, salmon, halibut, flounder, octopus, shrimp, crab, and herring (Alaska Department of Fish and Game 1973a and Tikhomirov 1964). Phoca vitulina richardi (richardsi)-harbor seal The land-breeding harbor seal is abundant throughout the southern part of Alaska (Figure 154). John Vania (U.S. Senate 1972) estimated that there are approximately 200,000 in Alaska. He also estimated that 30,000 animals could be harvested without affecting the population. Harbor seals are worth about 7.5 dollars apiece (Kenyon 1971), which represents a potential economic value of 225,000 dollars. Harbor seals are difficult to count since they do not usually congregate in hugh colonies like fur seals and sea lions. Small groups of 100 or less are found all along the Western Gulf coast on sand bars, beaches, and low rocks (Alaska Department of Fish and Game 1973a). The Phocidae are less adapted to land movement than either the sea lion or fur seal, and require a ready access to water (Scheffer 1972). Harbor seals are considered a nuisance because they raid salmon gillnets (Pike and MacAskie 1969). Bishop (1967) collected four harbor seal stomachs off Kodiak which contained octopus and squid. In a discussion on the pagophilic pinnipeds, Burns (1970) remarked that two subspecies of harbor seals occur in Alaska, richardi and largha. There are no skeletal differences, but largha is an ice- loving species. The largha species pups in May, before richardi. The earlier pups are born with a lanugo, a white fur covering. PRESENT KX CONCENTRATION [i Figure 154, Distribution and concentration of harbor of Fish and Game 1973a). seals (from Alaska Department o9f 361 Land-breeding seals give birth in June, and most pups have lost the lanugo by then. If pups are born earlier they retain the lanugo, but are deserted by their parents. Bishop (1967) presented a detailed discussion of reproduction, age determination, and behavior of the harbor seal. Callohinus ursinus-Northern fur seal Baker et al. (1970) presented a complete discussion of the fur seal which is used for the following discussion except where noted. The northern fur seal is found in the Western Gulf in the fall, winter, and spring. A herd of approximately 1.4 million migrates to and from the main breeding ground on the Pribilof Islands (Figure 155). They travel in small groups between 16 and 145 kilometers offshore. Portlock Bank and the Sanak Islands are noted as areas of concentration. The males winter in the Gulf of Alaska, then in June proceed north along the coast and through the Aleutian passes, False Pass, and Isanotski Strait (Murie 1959). The females winter from Bristish Columbia southward along the Pacific coast (Pike and MacAskie 1969). They arrive on the breeding grounds later than the males. After breeding, the main exodus occurs in November. Historically, fur seals always have been very important to Alaska. In 1970, 276 Americans depended on the fur seal as their only livelihood, while another 173 were seasonally employed. In this same year, the gross income from fur seals was 3,249,325 dollars. Between 40,000 and 50,000 fur seals have been taken annually (Kenyon 1971). Odontoceti-the toothed whales A number of the toothed whales are found in the Western Gulf (Figure 155). The harbor porpoise, (Phocoena phocoean; Dall's porpoise, Phocoenoides dalli; killer whale, Orcinus orca; and sperm whale, Physeter catoden, are the most common (Table 43). Pike and MacAskie (1969) stated that Dall porpoises are numerous in the Gulf of Alaska from February through September. They are probably migratory (Scheffer 1972). Harbor porpoises are more common inshore, while Dall's porpoises are more common in open waters (Scheffer 1949). Neither of these porpoises is commercially important in the United States, but the Danes and Russians use them for food (Scheffer 1972). Although Dall's porpoises are often caught in salmon nets (Mizue and Yoshida 1965), their principal food was found to be squid (Mizue et al. 1966). Killer whales are an important predator in Alaska and have a potential value as aquarium specimens (Scheffer 1972). They are hunted for food in Norway (Matthew 1968). The diet of killer whales may vary substantially. GRAY BLUE FIN SPERM BULLS FUR SEALS Figure 155. Migration routes of whales and fur seals (from Matthews 1968, Baker et al. 1970). to Table 43. Distribution and Abundance of Whales from Kodiak to Unimak Pass rare (+), moderately common (++), common (+++) Species Abundance Toothed Whales + North Pacific white-sided dolphin (Lagenorhynchus obliguidens) Short-finned pilot whale 1 record (Gopicephala macrorhyncha) Killer whale (Orcinus orca) Harbor porpoise (Phocoena phocoena) Dall's porpoise (Phocoenoides dalli) Sperm whale (Physeter catoden) Bering sea beaked whale (Mesoplodon stejnegeri) Goose-beaked whale (Ziphius cavirostis) + + + ¢ $¢ ¢ F Giant bottlenose whale (Berardius bairdi) Baleen Whales Blue whale (Balaenoptera musculus) Fin whale (B. physalus) Sei whale (B. borealis) Minke whale (B. acutorostrata) Humpback whale (Megaptera novaeanglieae) Gray whale (Eschrichtius robustus) * $+ ¢ ¢ + + Right whale (Balaena glacialis) 363 364 Nishwak and Handa (1958) recorded the diet to be fish, squid, octopus, dolphins, whales, and seals in that order. Rice (1968) dissected 10 stomachs and found the remains of seven sea lions, seven elephant seals, two harbor porpoises, one minke whale, two opah halibut, one halibut, two sharks, and a squid. Sperm whales winter in warmer latitudes, but males are often found as far north as the Gulf in summer (Rice 1971). Kodlov (1970) reported that they range north to the Bering Straits in search of their principal food, squid. Population estimates are uncertain. Omura and Ohsume (1971) estimated 167,000 male sperm whales in the North Pacific and stated that the population is not being harvested at maximum sustainable yield. Doi (1971) stated there are only 65,000 male sperm whales in the North Pacific and the population is definitely being depleted. Scheffer (1972) estimated the value of a sperm whale at 2,331 dollars. Mysticeti-Baleen whales. Baleen whales are so named because of the baleen plates they use to strain their principal foods; plankton, euphausids, pteropods and Calanus sp. (Matthews 1968). These whales are generally larger than the toothed whales and include the blue whale, Ballaenoptera musculus, which can measure 32 meters and weigh up to 108 metric tons (Storer and Usinger 1965). This whale is rare in the study area. The minke whale, Balaenoptere acutorostra, is the most common baleen whale in the Western Gulf. This small whale has not been commer- cially important in the Eastern Pacific, but both Norway and Japan utilize it (Rice 1971). With continued depletion of the larger whales by Soviet and Japanese whalers, hunting the smaller whales has become economically feasible (McHugh 1969). The fin whales, B. physalus, only recently hunted, have decreased from a recruitment population of 20,000 to 9,000 (Rice 1971). Not only is this below the maximum sustainable yield, it also indicates the susceptibility of these animals to hunting pressure. A similar trend was noted for sei whales, B. borealis, which were not formerly economically important. This stock is yet at or below maximum sustainable yield according to Rice (1971), who also noted a strange, contagious disease which causes the loss of the baleen plates. The eventual spread and effect of this disease is unknown. The gray whale, Eschrichtius robustus, is one of the few whales which has been definitively studied. After calving in the warmer California waters, gray whales begin to migrate up the coast, staying close to the shoreline (Scheffer 1972). Passing through the study area, they move into the Bering Sea and concentrate near Bering Straits before dispersing south to their breeding grounds again. The discovery of its calving grounds in the lagoons of Baja California in the early 1800s almost resulted in the species' extinction. By 1946-47, there 365 were only about 250 gray whales known to exist in the Pacific (Matthews 1968), but with protection, stocks have increased to around 11,000 (Rice 1971). TERRESTRIAL BIOTA Coastal Vegetation The Western Gulf coastline is characterized by rocky cliffs and steep slopes. Vegetation appears to be impoverished although a great variety of plant species occur in the study area (Table 44). Most of these plants can be arbitrarily sorted into groups or associations. The association nearest the coast can probably best be characterized by grass, Elymus arenarius, sometimes called wild rye grass. The habitat of this association is sand, either along beaches or occasionally on inland dunes. Common associates are Senecio pseudoarnica, an attractive yellow flower resembling a daisy; Lathyrus maritimus, a beach pea; Honckenya peploides, seabeach sandwort; and Mertensia maritima, the common oysterleaf. These species are encountered throughout the region on all sandy beaches, but species dominance varies as sand decreases and gravel and rocks increase. The dominant plant in rockier portions of the coast is Potentilla villosa, cinquefoil, which grows in pockets of soil formed in crevices of rocks. The other species found with Potentilla are highly variable due to the constantly shifting conditions on the wind-swept rocks. No static associations have time to form in these rockier areas (Hulten 1973). Further inland, the grasses are dominated by bluejoint or Calamagros- tis group. At times the distinction between this group and the beachgrass association is quite clear, as Murie (1959) reported: "Elymus, exposed to the sands of the sea, clung to the open face of this slope to the crest. At the exact point where the ground leveled off toward the interior, the other, more inland, grass formation began with a dense growth.'' Although the Calamagrostis group is dominant, two other grasses share the inshore habitat, the Poa, blue grass, and the Bromus, brome grass. An abundance of grasses is common along the coastline of many of the small islands, where the most notable vegtation is often grass cover. This obvious resource has led to great interest in these islands as possible agricultural areas with high potential for grazing (Gasser 1952). Burrowing animals often utilize these grassy areas. The dense mat of roots forms the roof of burrows for such rodents as voles and for burrowing alcides, such as pigeon guillemots and puffins. In winter, the grasses supply a readily available food source for these rodents when awakened by a drop in body temperature. 366 Table 44. Plant Species Described From Study Area (Hulten 1968) 1. COASTAL Agrostis exarata A. scabra Poa emines P. macrocalyx Puccinellia nutkaenis P. pumila Agropyron pauciflorum Elymus arenarius Carex macrocephala C. Gmelini Juncus arcticus Polygonum Fowleri Atriplex Gmelini A. alaskensis Stellaria humifusa- Sagina crassicaulis Honckenya peploides Cochleania officinalis Spergularia canadensis Draba hyperborea Draba hyperborea Fragaria chiloensis Potentilla fruticosa P. villosa P. Egedii Astragalus polaris Lathyrus maritimus Ligusticum scoticum Glehnia littoralis Armeria maritima Mertensia maritima Plantago maritima Galium aparine Senecio pseudo-Arnica S. nuda 2. SEAWATER/MARSHES Zostera marina Ruppia speralis Puccinellia Langeana Carex Lyngbyaei Rumex transitorius Hippuris tetraphylla Castilleja hyetophila 3. SANDY SOIL Poa glauca Hordeum jubatum Luzula acuata Salix glauca Rumex graminifolius 3. Continued Sagina intermedia Minuartia macrocarpa Silene acaulis Melandrium affine Papaver alaskanum Aphragmus Eschscholtzianus Oxytropis campestris Androsace alaskana Chrysanthemus bipinnatum Artemisia Tilesii A. borealis 4. ROCKS/STONY SLOPES Cryptogramma crispa Thelypferis limbosperma Cystopteris fragilis Polypodium vulgare Calamagrostis purpurascens Poa paucispicula P. brachyanthera Carex circinnata Bromus ciliatus C. nigricans Luzula spicta Tofieldia coccinea Lloydai serotina Salix rotundifolia Polygonum caurianum Claytonia Scammoniana C. sarmentosa Stellaria monantha S. laeta Cerastium Beeringianum Minuartia arctica M. rubella M. rossii Anemone parviflora Cardamine bellidifolia Drba fladnizensis D. hirta D. maxima Arabis lyrata A. hirsuta Sedum rosea Saxifraga oppositifolia S. serpyllifolia S. flagellaris S. bronchialis S. mertensiana S. bracteata Plant Species Cont. 4. Cont. Saxifraga unalaschensis S. foliolosa S. caespitosa Heuchera glabra Tellima grandiflora Chrysosplenium Wrightii Geum Tossii Supinus nootkatensis Astragalus unbellatus Oxytropis Maydelliana O. nigrescens Diapensia lapponica Androsace chamajasme A. septentrionalis Polemonium pulcherrimum Eritrichium Chamissonis Lagotis glauca Pedicularis capitata P. Kanei Galium boreale Campanula uniflora Aster sibiricus Chrysanthemum arcticum Artemisia globularia Arnica frigida Senecio resedifolius S. hyperborealis Hieracium triste 5. GRASSY SLOPES Botrychium lunaria B. boreale B. lanceolatum B. lanceolatum Carex anthoxanthea Luzula multiflora Cerastium aleuticum C. arvense Sagina saginoides Melandrium apetalum Drabe stenoloba D. borealis Saxifraga nivalis Astragalus alpinus Gentiana platuperfla Plantago lanceolata Campanula rotundiflora 6. WET SOIL Equisetum plaustre Trigolchin palustris Alopecurus alpinus A. aequalis 6. Cont. Agrostis borealis A. alaskana Calmagrostis inexpansa Deschampsia caispitose D. beringensis Vahlodea atropurpurea Cathbrosa aquatica Poa palustris P. nemoralis P. leptocoma Puccinellia kamtschatica P. glabra Festuca rubra Eriophorum Scheuchzeri E. russoleum Scirpus microcarpus Eleocharis palustris Carex dioica C. Mackensies C. glareosa C. disperma C. tenuiflora C. laevilulmis C. Kelloggii C. bicolor C. media C. stylosa C. Enanderi C. Mertensii C. macrochaeta C. spectabilis C. nesophila C. livida C. rostrata C. rhynchophysa C. saxatilis Lysichton americanum Juncus Drummondii J. Mertensianus J. falcatus J. alpinus J. triglumis J. biglumis J. bufonius Luzula wahlenbergii L. parviflora Tofieldia pusilla Sisyrinchium litorale Corallorrhiza trifida Populus balsamifera Salix fuscescens S. niphoclada S. myttillifolia S. Barclayi 367 6. Cont. Salix alaxensis S. sitchensis S. arbusculoides Myrica gale Alnus incana Urtica gracilis U. Lyalli Koenigia islandica Rumex arcticus R. fenestratus Oxytia digyna Polygonum pennsylvanicum Claytonia sibirica C. Chamissoi Stellaria crispa S. crassifolia S. calycantha S. sitchana S. ruscifolia Cerastium Fischerianum Sagina occidentalis Caltha palustris Trollius Kiederianus Delphinium glaucum Ranunculus hyperborea R. raptans R. gelidus R. Bongardi R. occidentalis R. occidentalis Barbara orthoceras Rorippa islandica Cardamine pratensis C. umbellata Parrya nudicaulis Leptarrhena pyrolifolia Saxifraga Lyallii S. hieracifolia S. ferruginea Chrysosplenium tetrandum Luetkea pectinata Potentilla norvegica Sanguisorba Menziesii Acer glabrum Epilobium latifolium luteum palustre +» anagallidifolium leptocarpum behringianum Hornemannii sertulatum Angelica genuflexa Romanzoffia unalaschensis Plagiobothris orientalis Mimulus guttatus Veronica americana Pinguicula vulgaris Plantago macrocarpa Galium triflorum HPA AeA 6. Cont. Galium kantschaticum G. trifidum Valeriana capitata Aster junciformes Petasites frigidus P. hyperboreus Arnica amplexicaulis A. Chamissonis Senecio congestus S. triangularis Prenanthes alata 7. WATER Isoetes muricata Equisetum fluviatile Sparganium angustifolium S. hyperboreum Potamogeton epihydrus . alpinus . gramineus » praelongus . perfoliatus Berchtoldi filiformis + vaginatus Calamagrostis deschampoides Carex aquatilis Montia fontana Nuphar polysepalum Caltha leptosepala C. natans Ranunculas trichophyllus R. confervoides Subularia aquatica Callitriche verna C. anceps Epilobium glandulosum Hippuris vulgaris H. montana Utricularia vulgaris U. minor wruotud 8. MEADOW & BOG Botrychium miltifidum Triglochin Maritimum Hierochloe alpina Phleum commatatum Arctagrostis latifolia Trisetum spicatum Poa arctica P. lanata P, malacantha P. hispidus P. Stenantha Arctophila fulva Festuca brachyphylla Bromus Pumpellianus 368 8. Cont. Bromus sitchensis Hordeum brachyantherum Eleocharis nitida Carex scirpoidea C. pyrenaica C. macloviana C. Lachenalii C. brunnescens C. Podocarpa Luzula tundricola Veratrum viride Veratrum viride Allium schoenoprasum Fritillaria camschatcensis Iris setosa Cypripedium guttata Dactylorhiza aristata Coeloglossum viride Plannanthera convallariaefolia P. dilatata Salix reticulata S. phlebophylla S. arctica S. cyclophylla S. stolonifera S. commutata Betula kenaica Alnus crispa Polygonum viviparum Aconitum delphinifolium A. maximum Anemone Richardsonii Ranuculus Eschscholtzii R. Maconuii Oxygraphis galcialis Thalictrum alpinum T. sparsiflorum Corydalis pauciflora Draba nivalis D. lactea Saxifraga punctata Parnassis palustris P. Kotzebuei Rubus arcticus Potentilla palustris P. hyparctica Sibbaldia procumbens Geum macrophyllum G. calthifolium Lathyrus palustris Vicia biflora V. langsdorffi V. adunca V. epipsila Epilobium angustifolium Cicuta Douglasii C. mackenzieana Conioselinum chinense 8. Cont. Angelica lucida Rhodendron camtschaticum Loiseleuria procumbens Andromeda polifolia Chamaedaphne calyculata Oxycoccus microcarpus Primula tschuktschorum P. cuneifolia P. egaliksensis Dodecatheon pulchellum Lysimachia thyrsiflora Gentiana algida G. glauca G. prostrata G. amarella G. aleutica Swertia perennia Menyanthes trifoliata Polemonium acutiflorum P. boreale Romanzoffia sitchensis Myosotis alpestris Veronica Wormskuolkii V. Stelleri Euphasia mollis Castilleja unalascheensis Rhinanthus minor Pedicularis Chamissonis P. verticillata P. parviflora P. Langsdorfii P. sudetica P. Oedera Pinguicula villosa Solidago multiradiata L. lepida A. subspicatus Erigeron peregrinus Antennaria monocephala A. Friestiana A. rosea Achillea borealis Artemisia arctica Arnica hessingii A. latifolia Senecio lugens Taraxacum ceratophorum T. triglonobum T. kamtaschaticum Hieracium gracile 9. TUNDRA & HEATH Lycopodium selago appressum Eriophorum angustifolium Trichophorum caespitosum 369 9. Cont. Carex leptalea C. pauciflora C. canescens C. Buxbaumii C. pluriflora C. limosa Juncus filiformis J. Oreganus Spiranthes Romanzoffiana Malaxis monophylla Betula nana Anemone narcissiflora Drosera anglica D. rotundifolia Saxifraga hirculus Rubus chamaemorus Dryas octopetala D. integrifolia Sanguisorba stipulata Empetrum nigrum Ledum palustre Phyllodoce aleutica Phyllodoce aleutica Cassiope Stelleriana C. lycopodioides Arctostaphylos alpina Vaccinium vitis-idaea V. uliginosum Pedicularis labradorica Campanula lasiocarpa Saussurea angustifolia 10. WOODS/ACID SOILS Lycopodium selage L. annotinum Lycopodium clavatum L. alpinum Selaginella selaginoides Equisetum silvaticum E. pratense Botrychium virginianum Adiantum pedatum Thelypteris phegopteris Athyrium felix-femina Polystichum Braunii Dryopteris dilatata Gymnocarpium dryopteris Blechnum spicant Picea sitchensis Hierochloe odorata Cinna latifolia Streptopus amplexifolius Plananthera obtusata Listera cordata Salix depressa S. pulchra S. Scouleriana Moehringia lateriflora Coptis trifolia Actae rubra Mitella pentandra Ribes lacustre R. hudsonianum Spiraea Beauverdiana Aruncus sylvester Sorbus scopulina S. sitchensis Amelanchier florida Rubus pedatus R. idaeus R. spectabilis Rosa nutkana Geranium erianthum Viola glabella Shepherdia canadensis Circaea alpina Echinopanax horridum Osmorhiza purpurea 0. chilensis Heracleum lanatum Cornis suecica C. canadensis Pyrola asarifolia P. minor P. secunda Moneses uniflora Cladothamnus Vacinium ovalifolium Trientalis europaea Gentiana propinqua Sambus racemosa Viburnum edule Linnaea borealis Erigeron acris 11. INTRODUCED Phleum pratense Agrostis gigantea Avena sativa Poa trivialis P. pratensis Bromus tectorum B. hordaceous Agropyron repens Triticum aestivum Rumex acetosella R. acetosa R. obusifolia R. cripus Polygonum aviculare Chenopodium album C. Berlandieri Stellaria media 370 ll. Cont. Cerastium fontanum Spergula arvensis Ranunculas repens R. acris Thlaspi arvense Sisymbrium altissimum Brassica juncea B. rapa Capsella bursa-pastoris C. rubella Erysimum cheiranthoides Potentilla gracilis Trifolium hybridum T. repens Gilia achilleaefolia Galeopsis bifida Veronica serpyllifolia Plantago major Anaphalis margaritacea Anthemis cotula Matricaria matricariodes Senecio vulgaris Taraxacum officinale Sonchus arvensis 12. PARASITIC Crobanche fasciculata Boshniakia rossica 371 372 Even further inland, Hulten (1960) described a "mosaic" of alpine heath and meadow in which Carex, sedge, dominates. Sedge is widespread, being cited by Hanson (1951) as the dominant species of several coastal communities on Kodiak Island. The tall vegetation of most of the Alaska Peninsula and Kodiak Island is composed of birch, Betula nana; willow, Salix sp; and alder, Alnus crispa. The association of Sitka spruce, Picea stichensis, and birch, Betula kenaica, extends about halfway down Kodiak Island and reaches the general vicinity of Becharof Lake on the mainland (Murie 1959). Observers disagree, but the forest may be slowly advancing southwestward along the Peninsula on Kodiak Island. Griggs (1934) believed that the forest had not yet reached its climatic limit. Capps (1934) reported the forest edge advancing about one mile per century. Coastal Fauna The most likely land birds to come in contact with the coastal waters are falcons and eagles, which nest in cliffs and trees along the coastline. These large, conspicuous birds usually prey on the marine life of an area. Murie (1959) noted in particular that the northern bald eagle, Haliaeetus leucocephalus, preys on murres, fulmars, and cormorants. Eagles also prey on a variety of other marine life, including herring, salmon (usually after they have spawned), Dolly Varden, sea urchins, clams, and crabs (Bent 1938). Kenyon (1969) reported that bald eagles often scavenge dead sea otters. The eagle's marine diet may have some adverse consequences. Remains of murres, fulmars, and cormorants have been found in eagle nests, where young eaglets may be particularly susceptible to many types of contamination from these birds of prey. Furthermore, eagle eggs with abnormally thin shells, typical of birds feeding on organisms with a high pesticide content, have been reported from Kodiak Island (U.S. Departments of Agriculture and the Interior 1972). The peregrine falcon, Falco peregrinus pealei, has been seen in the study area, but its population is uncertain. Murie (1959) noted the endangered bird feeding on least and crested auklets. Sowl thought he saw a peregrine on Chakliut Island, but was unable to make positive identification.! Cade (1960) said, "On the Alaska Peninsula and throughout the Aleutians, sea cliffs of volcanic origin provide abundant nesting habitat for peregrines...there can be little doubt that in this region these birds (cliff-nesting seabirds) provide the bulk of the food of peregrines." On a nest map, Cade noted that he had seen several peregrine nests in the Western Gulf and a gyrfalcon, Falco rusticola, nest on Kodiak Island. Gyrfalcons breed in the Aleutians and throughout Alaska (Peterson 1961). Gyrfalcons feed on various birds including marine and shore birds (White and Springer 1965). lipid. 373 The smaller rodents are numerous along the Western Gulf shoreline, nesting among the Elymus and Calamagrostis associations. There is some evidence that their numbers are cyclic, much like the snowshoe hare. After the peak of one apparent cycle, the tundra vole, Microtus oeconomus, was reportedly decimated on the Alaska Peninsula in the winter of 1953-1954 (Schiller and Raush 1956). Having observed a number of beetles, ticks, and mites infesting a heavy population of Microtus oceanomus on Amak Island, Murie (1959) speculated that "...an aggregation of more or less parasitic invertebrates in a dense mouse population could be an important element in the cyclic behavior of these rodents." In support of his theory, Murie observed that both lemmings and meadow mice (tundra voles) were scarce on the Alaska Peninsula during that same summer, and that "...none of the beetles mentioned above were noticed that summer, either on the Alaska Peninsula or on Unimak Island." Shrews, Sorex sp., are also abundant in the study area. Schiller and Rausch trapped 12 Sorex vagrans around an abandoned cannery at Kukak Bay. Sorex cinereus were reported by Osgood (1904) as numerous in the coastal region. Shrews are insectivores, and most predators do not like their taste. Lepus othus, the tundra hare, is found on the Alaska Peninsula south of the forest (Schiller and Rausch 1956). This hare does not frequent coastal areas, except in peak population years. The varying hare, Lepus americanus, was introduced to Kodiak in 1934, and is now found on the south end of the island in willow and alder associations.1} Ground squirrels, Citellus parrgi, are common on the Peninsula and Kodiak, as well as near shore islands. They can apparently swim some distance (Marie 1959). Martes americana, the marten, occurs in the forests of the Alaska Peninsula, but is rarely found in the coastal study area. It has been introduced on Kodiak. Mustela erminea, the ermine, occurs in habitats throughout the study area, and is frequently found along the coast. The ermine feeds on small mammals and birds, and prefers to kill its own food rather than scavenge. Schiller and Rausch (1956) noted an ermine feeding on a glaucous-winged gull. The red fox, Vulpes fulva, is indigenous to Kodiak Island and the entire Western Gulf area. This fox is particularly abundant along the coast, where it feeds on rodents in the grasses and forages along the beaches for a variety of marine and intertidal life. Murie reported that Wetmore et al. (1945) observed these foxes feeding on flounders stranded on the beach at Thin Point. Murie (1959) himself observed that red foxes ''...spend much time on the beaches of these islands, where they dug for clams they located by scent. They also picked up crabs at low tide and ate codfish or other carrion thrown up on the beach."' Murie cited Beals and Longworth as finding fox droppings ly. Troyer, Former refuge Manager, Kodiak National Wildlife Refuge. Personal communication. 374 composed almost entirely of locally abundant beachfleas. At Dolgoi Island, Murie (1959) examined 57 red fox scats. One dropping contained 100 percent sea urchins, and three were composed entirely of beachfleas. These findings are summarized in Table 45. The blue fox, Alopex lagopus, is not common in the study area, but it does occur. Where it has been introduced for fox-farming on offshore islands, the blue fox has become very abundant, at times decimating and eliminating the bird life of an island. Sowl observed that where old cabins existed, (presumably indicating past fox-farming) there were apt to be few if any birds.! Further west, in the Aleutian Chain, foxes present a very real threat to some endangered bird species (Murie 1959). Racoons, Procyon lotor, were introduced to Long Island off Kodiak. Murie (1959) reported that there were still some left in 1936, although they were not flourishing. None survive today. _ Mink, Mustela vison, have been sighted throughout the Alaska Peninsula. Mink were introduced to Kodiak and Afognak Islands via Long Island. Schiller and Rausch (1956) captured one, but after thriving on a diet of voles, it died when fed a small fish. Bones of the fish pierced the abdomen of the mink. It seems unlikely that mink feed on fish in the wild, though fish meal is one of their principal foods in captivity. Gulo luscus, the wolverine, though never found in great numbers, does occur on the Alaska Peninsula and on Unimak Island. Voracious by nature, wolverines frequently forage along the beaches and will eat anything feasible. Beals and Longworth (Murie 1959) reported tracks on Unimak Island "'...on practically all the beaches from Swanson Lagoon to Banjo Bay."" The Alaska Department of Fish and Game (1973a) reported that wolverines are particularly fond of marine mammals which have died at sea and been washed ashore. The land or river otter, Lutra canadensis, resembles its marine cousins so closely that the two often share the same habitat. Wetmore reported that land otters were frequently seen '"'...swimming boldly out to the islands, lying off the coast." River otters eat small fish, as well as freshwater and marine aquatic invertebrates (Burt and Grossenheider 1964). The lynx, Lynx canadensis is found throughout the Alaska Peninsula, but is most common in the forested zone where it feeds on the abundant snowshoe hare. Generally not a scavenger, the lynx is unlikely to frequent the beaches of the area. Although the snowshoe hare was artifically introduced on Kodiak, no one has yet imported these large cats to that island. lLeroy Sowl, Supervisory Fish and Wildlife Biologist, U.S. Bureau of Sport Fisheries and Wildlife, Anchorage. Personal communication. 375 Table 45. Composition of 27 red fox scats Item Occurrence Percent Microtus 38 52 Bird 16 21.9 Beach fleas 6 8.2 Sea urchin (Strongylocentrotus) 4 , 5.4 Mussel (Mytilus) 2 2.7 Heavy cloth 2 2.7 Brown paper 2 2.7 Hair seal (Phoca sp.) 1 1.3 Small fish 1 1.3 Large bone 1 1.3 376 The wolf, Canis lupus, occurs throughout the study area. Turner (1886) stated that wolves crossed over the ice to Unimak Island. This may occur in severe winters throughout this region, but most of the islands are not large enough to support a population of wolves. Wolves are hunters and prefer to kill their own food; they will continue to feed on a kill for many weeks (Mech 1970). During severe winters, however, they will scavenge along the beaches, feeding on marine mammal carcasses when available. Murie (1959) reported that in the winter of 1918 the fur of two wolves was greasy, ''...showing that they had been living off a whale carcass." The brown bear, Ursus arctos, is one of the study area's most lucrative attractions (Figure 156). Hunters and photographers come from all over the world to stalk these monsters. In 1959, a total of 232,106 dollars was spent in Alaska to hunt the Kodiak bear; the greater portion of this money is spent by people from outside the state.! Despite its reputation for ferocity, these bears will generally retreat from people when possible 2 Garbage dumps are constant attractions for bears which often creates a hazard (Clark 1957). Bears have well-defined movement patterns (Figrue 157). ‘In spring, they leave their dens and move to the coast where they graze on emerging vegetation and forage for carrion left over from winter. When the salmon run begins, bears congregate along the streams and lakes. As soon as berries begin to ripen, the bears abandon salmon areas and feed almost exclusively on berries until denning. During the winter, if awakened, they are likely to scavenge the beaches again in search of carrion. Being omnivorous, however, they also feed on seaweed at these times. Sowl observed a bear swimming to an island off the Alaska Peninsula and theorized that it might be feeding on bird eges.> Many ungulates have been introduced to the Western Gulf area including bison, Bison bison; Sitka black-tailed deer, Odocoileus hemionus sitkensis; Roosevelt elk, Cervus canadensis roosevelti; Dall sheep, Ovis dalli; mountain goat, Oreamnos americanus; and reindeer, Rangifer tarandus tarandus. In particular, Kodiak Island has been a noted experimental area for introducing exotic species, such as Sitka black-tailed deer (1934); elk (1927); beaver (1929-31); varying hare (1935-36); and muskrat (1929). Unsuccessful introductions to this island include mink, marten, Dall sheep, moose, and spruce grouse (U.S. Department of the Interior 1972). Ungulates are likely to frequent the beaches and coastal areas only in times of heavy snow when beaches may be the easiest places for travel. When very hungry, they will eat seaweed. lwillard Troyer and Richard Hensel. "The Brown Bear of Kodiak Island." Unpublished manuscript. U.S. Bureau of Sport Fisheries and Wildlife, Anchorage. 2tbid. SLeroy Sowl, Supervisory Fish and Wildlife Biologist, U.S. Bureau of Sport Fisheries and Wildlife, Anchorage. Personal communication. [J] Hasitat CONCENTRATION ON STREAMS Figure 156. Distribution and concentration of brown bear (from Alaska Department of Fish and Game 1973a). LLE Figure 157. ZONATION IN BROWN BEAR DENNING- HABITAT WINTER BERRIES /SALMON SUMMER-FALL SALMON FISHING SPRING - SUMMER SCAVENGING/ FORAGING COASTAL ZONE I EARLY SPRING TO 100° Zonation in brown bear habitat (from Clark 1957). gle 379 Caribou, Rangifer tarandus granti, and moose, Alces alces, are indigenous to the study area and range throughout the Alaska Peninsula (Figures 158 and 159). The caribou herd on the mainland contains approximately 14,000 animals, which migrate in a traditional, though relatively leisurely, fashion. Generally, the herd stays on the north side of the Alaska Peninsula. During winter, a few small bands congregate on the west side of Pavlof Bay. Caribou are reported to migrate to Unimak Island occasionally by swimming across Isanotski Strait. There is a resident herd of at least 1,500 individuals on Unimak island. This herd usually congregates along the northside lowlands, has no specific calving grounds, and does not migrate (Hemming 1971). ECOLOGICAL SYSTEMS AND MECHANISMS Ecologists often disagree on terminology and subdivisions of the environment. Classification in the Western Gulf area is particularly difficult, because almost no ecological research has been done--either in terrestrial regions, the intertidal zone, offshore waters, or on the outer continental shelf. For example, energy flow, predation, competition, critical limiting factors and other aspects of food chain dynamics are not well known. Most terrestrial information derives from reconnaissance and is descriptive in nature. According to Rickets et al. (1968), three important interlocking factors--degree of wave shock, the bottom type, and tidal exposure-- determine the distribution of marine fauna, particularly invertebrates, within a specific habitat. Wave shock is determined by the size of the unbroken water body, water depth, and wind velocity, and direction. The presence of eelgrass and other factors which modify wave force determine the species composition of animal communities. The greatest modification of wave force is evident in closed bays, sounds, and estuaries, where fauna are different from those which inhabit the open coast. Some species occur in both closed and open areas, but those found in closed locations frequently differ in habit and habitat from those found in exposed areas. The bottom type (clay, sand, gravel, silt, etc.) is important, because the various species of benthos have different requirements that can be satisfied only by specific bottom types. For instance, some animals with holdfasts require a rocky substrate while others, such as some clams, require sandy bottoms. Tidal exposure--the length of time that intertidal fauna are exposed to air--varies from zones above the level of high spring tides, where animals are splashed by waves or spray only a few times each month, to the level of low spring tides, where species are uncovered only a few hours each month. Many protected estuaries and intertidal waters exist within the broad category of "ice affected coast" (Figure 160). These waters HABITAT RQ WINTERING QQQQ cacvinc §=[ GF a 3a Figure 159 Z z SQ e < ac E z WW ° z ° oO FIGURE 160 Marine Ecosystem of the Western Gulf of Alaska (With Coastal Zone Information Included) Boundary of Continental Shelf The continental shelf boundary consists of the offshore waters to a depth of 200 m. Estimated shelf area is 60,000 square miles. Plant growth is dependent upon light received and the presence of nutrients. Mixing by wave and current action brings nutrients into the lighted zone. Shelf depths are shallow enough to support abundant marine life. Drifting singlecelled plants occur throughout the zone. More complex plants occur along particular coastal areas. Plant productivity is considered moderate (220 kg./hectare). Animals present are microscopic drifters; bottom processors (worms, etc.); clams, sponges, crabs, sea urchins, starfish, bottom fish (halibut, flounders, etc.); free- swimming fish (salmon, pollock, herring, trout, etc.); jellyfish, seals, sea lions; sea otters; several species of toothed and baleen whales, and narwhales (rare). Many species of shorebirds and oceanic birds are found near coasts. The worldwide shelf area supports approximately 90 percent of the ocean fisheries, and provides sufficiently shallow depths for mineral exploration and oil drilling. Its waters are also used extensively by man for transportation and recreation. Wave Beaten Coast Wave beaten coast includes all seaward coasts in the Gulf of Alaska; waves are the primary mixing agent. Estuaries are generally wide, short indentations in land, with depths of less than 100 m; they support larval and immature stages of most marine animals. Plant productivity is highest in these areas; kelp and intertidal seaweeds occur. Most types of marine fauna are found here, with a high incidence of clinging and intertidal species (mussels, barnacles, snails, and small crabs). The habitat favored by bald eagles is abundant. Many estuaries are highly prooductive. The wind generally is brisk; the climate is maritime; fishing is good. The coast provides many anchorages for ships. Fjord Estuaries Coasts here were eroded by past glaciers and are protected from the direct pounding of sea waves. The water is stratified, limiting high plant production to a period in early spring; such production is low during the summer. Kelp and intertidal seaweeds are found here. Phytoplankton productivity is variable. Micro and macro marine fauna are essentially the same as those found along the wave beanten coast. The estuaries may exchange water as infrequently as once per year; none are known to be stagnant. Occasional high winds blow through the valleys. The climate is maritime. There are many shelters, 382 anchorages, and harbors in this region. Oceanic The ocean depth in these areas is greater than 200 m. Plant productivity is low due to a limited photosynthetic zone. Most animal life is found above mid-depth. Baleen and toothed whales and seals are present, as are most Alaskan shore and oceanic birds. Shipping and fishing are the main major commercial activities in this region. 383 165° “oo se VOLCANIC ASH 160° Continental Shelf Boundary . Vjerd Fr annexe Sandy Coust went Rocky Coant seme Rocky Coast w/Sancy Bottom a atstae Muccy Bottom kigure 160. Coastal Lone Characteristics, hestern Gulf (adapted from Coast and Geodetic Survey Navigation Charts). 156° 180° vss 385 are among the most productive in the world. Mechanisms and conditions interplay here to maintain energy transport at rates often considerably greater than those in offshore waters. Tidal action promotes rapid circulation of nutrients and food, and aids in the rapid removal of waste products. Diverse plant species and life forms--phytoplankton, benthic microflora, seaweeds, and sea grasses--provide a relatively continuous photosynthetic production during the growing season throughout the water mass. The close contact between producers and consumers enhances biomass productivity. Large eelgrass beds provide some protection for communities by partially dissipating wave and tidal forces (Odum 1963). Ecological relationships in the marine environment are influenced greatly by the prevailing westerly current pattern; the rugged, irregular bottom relief of this area, and the migratory life style of many faunal species. These three factors combine to yield a complex and ever changing pattern of environmental conditions. Due to the lack of substantial ecological investigation within this marine system, it is possible to provide only a general overview of these conditions. The Alaska Current continually carries suspended and planktonic matter in and out of the Western Gulf. The current flows into the study area from the east and flows out in a westerly direction, either south of the Aleutian Chain, or north into the Bering Sea. A portion of this organic matter becomes concentrated in eddies and gyrals adjacent to the main current flow, as Lisovenko (1964) found in his study of Pacific Ocean perch larvae and eggs. In this manner, the rate of passage or loss of organic production from the study area may be somewhat retarded. In comparison to other coastal environments, this study area receives little organic or inorganic matter from the adjoining terrestrial environment, due to its short, steep drainage gradients and extensive volcanic topography. Thus, materials contributed from adjacent marine systems to the Western Gulf currently can be expected to have a far greater influence on its marine environment than does the input of materials from adjacent terrestrial systems. The rate at which organic production within an environment is utilized, and thus the rate at which energy is transferred between stages of the food chain, is indicative of community metabolism. The ratio of phytoplankton standing crop to primary productivity provides one measure of this parameter (Table 46). In the vicinity of Unimak Island, a phytoplankton standing crop can accumulate with a low primary productivity; while eastward over the continental shelf and slope, primary productivity is rapidly consumed with little accumulation of a standing crop. Larger zooplankton populations eastward of Unimak Island serve to substantiate the higher community metabolism and rate of energy transfer in this portion of the study area. Insufficient data exist to extend this analysis into the Kodiak area, but that area might be expected to exhibit a similar high rate of energy transfer. Station No. 44 41 43 44 45 46 47 48 49 Table 46. Community Metabolism of Primary Producers in the Surface Waters of the Western Gulf of Alaska (station locations are indicated in Figure 66). Reference McRoy et. al. (1972) Faculty of Fisheries (1961) McRoy et al. (1972) McRoy et al. (1972) McRoy et al. (1972) McRoy et al. (1972) Faculty Faculty Faculty Faculty Faculty of Fisheries of Fisheries of Fisheries of Fisheries of Fisheries (1961) (1961) (1961) (1961) (1961) Position 54°15'N, 54°20'N, 54°17'N, 54°27'N, 54°10'N, 53°953'N, 54°04'N, 54°18'N, 54°22'N, 55°01'N, 55°11'N, 164°34'W 164°53'W 164°19'W 164°11'W 164°14'W 164°17'W 161°12'N 159°50'W 157°19'W 153°58'W 152°51'W Primary Productivity mg C/m3 /hr 1.35 1.95 0.85 0.15 0.40 0.55 2.824 0.805 0.387 1.174 0.974 Standing Crop mg chl a/m> 1.37 1.6 0.2 0.6 0.5 0.5 0.2 0.09 0.28 0.28 Ratio .(Standing crop/productivity) 0.703 1.882 1.333 1.500 0.909 0.177 0.248 0.233 0.239 0.287 98 387 The abyssal depths south of the study area are a "semidesert,'' with relatively little biomass per unit area. Compared to the total depth of the water column, the photosynthetic zone in this region is extremely small, and productivity may often be limited by an insufficient nutrient supply. The complexity of the submarine topography and sediments serves to provide numerous, varied habitats and support a rich, diverse fauna. The many canyons and gullies in this region provide convenient habitat for species which must migrate between different depths to fulfill specific life stage requirements. The irregular topography disrupts normal current patterns to create eddies and other unique circulation features which further dissect the environment into numerous subhabitats, each with its own unique physical conditions, capable of supporting a unique assemblage of flora and fauna. Four major migratory patterns characterize faunal movements in this region: Offshore-onshore movements; anadromous species; migrants along the coastal region, and migrants between depths. Flatfish exhibit an offshore-onshore migratory pattern, thus aiding the transport of organic production into and out of the coastal bays by making use of the coastal environment when it is most productive and avoiding it when physical conditions may highly stress the organism, such as during the winter season. These species tend to utilize the continental shelf extensively when not inhabiting coastal bays. Anadromous species, such as salmon, exploit the productivity of the freshwater environment during reproductive and initial life stages. Maturing individuals pass through the coastal zone on their way to and from offshore waters where they spend most of their saltwater existence. Species such as halibut and Pacific Ocean perch leave the study area periodically to spawn and overwinter in the more hospitable habitats of adjacent marine regions. Favorable currents return their eggs and larvae to the Western Gulf, while adults return under their own power. The king crab is an example of a species which migrates vertically within the study area, moving between shallow spawning grounds and deeper feeding areas. Species which migrate vertically benefit from the unique character of different habitats within the study area at various stages of their life history; thus, they utilize the diversity of this region to their advantage. Together, these movements of fauna circulate the organic production which they have assimilated in any one location within the study area throughout the entire region, thus typing all systems into a unit- ecosystem whose major characteristic might best be described as constant dynamic change. 388 Specific in-depth, freshwater ‘ecological studies have not been conducted within the study area. In the oceans, life is dominated by physical factors--waves, tides, currents, salinities, temperatures, pressures, and light intensities-- which largely determine the structure of a biological community. Conversely, in the terrestrial environment, physical and biological factors interacting together determine the fate, distribution, and abundance of plant and animal species, with biological factors--succession, competition, and predation--directing this process in certain situations (Odum 1963). Plant communities have been defined by grouping species. The predominance of an individual species within a plant community may vary greatly from place to place. Together, the plants and animals in an area comprise the biotic community, and in conjunction with their accompanying physical setting, form an ecosystem. The ecosystems depicted in Figure 161 characterize the Western Gulf area. (Joint Federal-State Land Use Planning Commission 1973, Viereck and Little 1972). The maritime climate of the Western Gulf moderates the temperature but creates a heavy cloud cover with a resultant decrease in solar energy. Consequently, most of the land is covered with low, slowly growing vegetation. Primary consumers are herbivores and are widely distributed in both terrestrial and marine ecosystems. Secondary consumers, predators, also utilize both land and marine life. The intertidal zone is relatively bountiful in winter when food may be scarce elsewhere. Many species living on land forage far out at sea and enrich the land with nutrients from the sea. In addition, oceangoing species such as salmon, spawn and die in fresh water. Their carcasses contribute significant nutrients to the land. In return, the nutrients from the land leach to the ocean. In ages past, the environment was quite different. For about 500 million years, the world climate has alternated between warm periods of extensive tropical flora and ice ages. An ice sheet, centered on the U.S.-Canadian border and believed to have been as much as 4.3 km. thick, once covered all of the study area. Between 4,500 and 7,500 years ago, temperatures were about 2 C degrees warmer than now; the Arctic Ocean, for example, was ice-free. Presently, the worldwide temperature appears to be decreasing. Current glacier recession will halt if the temperature continues to decrease.1 ly, Mitchell, Jr., Project Scientist for Climatic Change, Environmental Data Service. Silver Springs, Maryland. Personal communication. FIGURE 161 Terrestrial Ecosystems of the Western Gulf of Alaska Moist Tundra Moist tundra consists of meadows of tall grass interspersed with dense, low, heath shrubs; found between sea level and 457 m. elevation, occupying poorly drained, shallow, loam soils of upper mountain slopes, and wet, silty soils on lower slopes and drainages. Mammals in such areas are the brown-grizzly bear, wolf, wolverine, caribou, Arctic hare, red fox, Arctic fox, lemming, and mice. The birds are ptarmigan, ravens, songbirds, dabbling and diving ducks, geese, brant, swans, grebes, loons, sandhill cranes, shorebirds, hawks, bald eagles, jaegars, snowy, and other open country owls. Man derives much of his livelihood from the sea and rivers of the region, gathering important edible herbs and roots, fuel, insulation, craft and building materials and obtaining meat, hides, and furs. The climate is cool. Coastal areas are subject to severe storms and great sea waves. Wet Tundra Wet tundra is usually found in areas with little topographic relief; standing water is almost always present in summer, and numerous shallow lakes are common. Dominant vegetation is sedge and cottongrass, usually forming a mat; a few woody and herbaceous plants occur on drier sites, and rooted aquatic plants occur along shorelines and in shallower lakes. Associated plants are lichens, mosses, low-growing willows, dwarf birch, Labrador tea, cinquefoil, beach rye, lowbush cranberry, bog cranberry, and occasionally rooted aquatic plants (bur reed, pond weed, pendent grass, and mare's tail). Soils are composed of poorly drained peat layers overlying silty and sandy sediments. Decomposition of vegetative growth by soil organisms is inhibited by cool temperatures. Less vegetation decomposes than is produced annually, resulting in sphagnum and sedge peat accumulation. Mammals are brown-grizzly bear, wolf, wolverine, caribou, moose, Arctic hare, mink, weasel, muskrat. Birds are ptarmigan, ravens, songbirds, dabbling and diving ducks, other geese, brant, swans, shorebirds, jaegars, marsh hawks, and open country owls. This system produces significant amounts of forage for reindeer and caribou, and provides abundant rich waterfowl habitat. The climate is cool and windy. Coastal areas are subject to wave erosion and damage by great sea waves. Alpine Tundra Alpine tundra is found in mountainous and exposed areas and consists of barren rocks and rubble interspersed with low herbaceous and shrubby plant mats, most prominently low heath shrubs, such as cassiopes and 390 mountain-heaths. Other important species include bog blueberry, crowberry, mountain cranberry, alpine azalea, and several dwarf willows. This system occurs above 305 m., occupying lower mountain, hill, and ridge areas. Mammals are brown-grizzly bear, wolf, wolverine, elk (Afognak Island), mountain goat (Kodiak Island), fox, marmot, ground squirrel, lemming, and pika. Birds are ptarmigan, ravens, songbirds, some shorebirds, golden eagles, marsh hawks, gyrfalcons, snowy, and other open country owls. Man's activities in this system are usually of short duration, and limited to hunting and recreation. This system is usually moisture deficient in summer. Plant regeneration is often extremely slow. High Brush High brush consists of dense to open deciduous brush, basically of two types: (1) Coastal alder thickets, extensive Sitka alder thickets often having a well developed grass and fern understory. Associated species are bluejoint, devilsclub, willow, Sitka mountain ash, currant, thimbleberry, salmonberry, blueberry, and huckleberry. (2) Floodplain thickets are dominated by willows and alders. Associated shrubs include dogwood, prickly rose, raspberry, buffaloberry, highbush cranberry. This system develops rapidly on newly formed alluvial deposits that are periodically flooded. The high brush ecosystem is found on a variety of soils, including those poorly drained with permafrost in low river valleys, and wet to well-drained shallow upland soils on moraines, outwashes and mountain slopes with intermittent permafrost. Mammals are brown-grizzly bear, moose, wolf, wolverine, snowshoe hare, mountain goat (Kodiak Island), red fox, lynx. Birds are ptarmigan, ravens, hawks, owls, and songbirds. Sitka Spruce Forest A dense, evergreen forest ecosystem, Sitka spruce is the sole conifer on Afognak and Kodiak Islands. The understory includes crowberry, bearberry, rose, devilsclub, elderberry, salmonberry, highbush cranberry, red-osier dogwood, and ferns. This system is found on steep mountain slopes and valleys bordering the coast, descending from above 150 m. near Cook Inlet and on Afognak Island to sea level at its western limit on Kodiak Island. The substrate is composed of a complex of permafrost-free land surfaces and soils common to steep rocky slopes, glacial masses, extensive outwashes and morainal areas. Soils are shallow, coarse, loamy and well-drained near timber line. On lower slopes and high moraines soils are stony, gravelly, well-drained, and productive. Poorly drained, mucky peat soils occupy slopes and depressions in some areas. Soils on Afognak and northern Kodiak Island include surface ash layers. Mammals are brown-grizzly bear, wolf, wolverine, red fox, lynx, marten, squirrels, Roosevelt elk (on Afognak Island). Birds are blue grouse, ravens, crows, diving ducks, Canada geese, grebes, loons, bald eagles, hawks, songbirds, and woodland owls. The climate is maritime and wet. 391 Ice and Persistent Snow Precipitation is heavy; average runoff is high year-round, peaking in midsummer, with distinct diurnal differences in runoff volume. Outburst floods occur occasionally; the ice and snow have a great effect on the streams. The alpine tundra ecosystem is closely associated. Algae occur on glaciers, and coarse rock debris is common on newly exposed areas. Meltwater carries rock material downstream to form terraces and outwash deposits. Exposed materials are soon invaded by lichens and mosses, followed by annual grasses, shrubs, and alder. Further succession may take place. Mammals are sheep, goats, caribou (which utilize such areas primarily for insect relief and as cool rest areas). Birds are numerous, and include ravens, eagles, and falcons. Airflow is generally downhill, and cool. Lakes Circulation is usually restricted in deep lakes, and stratification is evident. Production is higher in shallow lakes due to greater circulation. Shallow lakes usually contain the following aquatic plants: (1) Rooted submerged aquatics, such as bur reed and pond weed; (2) rooted emergent species, such as pendent grass, mare's tail, and marsh fivefinger. Lake bottom materials vary from bedrock to clays, including stones, gravels, and silts. Small shallow lakes in low bog areas fill rapidly, and usually reach the high brush stage. Submerged mucks consisting of mineral and organic deposits are the best producers of underwater vegetation for aquatic life. Mammals are moose, beaver, mink, weasel, muskrat, and land otter. Birds are songbirds, dabbling and diving ducks, geese, swans, grebes, loons, shorebirds, bald eagles, owls, hawks (including ospreys and peregrine falcons). Fish are trout, grayling, char, salmon, and others. Certain lakes are critical as spawning and nursery areas for salmon, and as breeding, nesting, and resting areas for migratory waterfowl. Shorelines and shallow lakes are heavily used by moose. Many lakes are used for recreation. Riverine Generally, streams are either glacial or non-glacial. Streambeds vary from sandy to gravelly and stony, with fine sands, silts, and silty clays in areas of slow-moving water. As streambeds change course, plant invasion occurs. Glacier-fed streams carry large amounts of sand and silt. Mammals are brown-grizzly bear, wolf, wolverine, moose, beaver, red fox, lynx, mink, weasel, muskrat, and land otter. Birds are songbirds, ravens, owls, dabbling and diving ducks, geese, grebes, loons, bald and golden eagles, hawks (including ospreys and peregrine falcons), and shorebirds. Fish are grayling, trout, char, salmon, and others. River channels are constantly changing. Heavy use of this system is made by man for recreation. rival wet tundra Moist tundra alpine tundra and barren high brush Figure 161. Te trial ecesysters ulf of Alaska (fre J Ure Planti: Siaska TG73). Z6E 393 Flora in the study area have changed considerably in response to these climatic changes. Fossilized trees as large as 3 m. in diameter are found along the northwest coast of Unga Island, the largest island of the Shumagin Group. These fossils have been identified as belonging to the genera Sequoia or Metasequoia, which were widespread over the northern hemisphere from about 35 degrees north latitude to beyond the Arctic Circle during warmer times. Mastodons and mammoths also flourished in what are now Arctic and sub-Arctic regions. Metasequoia sp. flourished more than 20 million years ago. Its growth was apparently restricted to valleys and areas of low to moderate elevation, possibly flood plains, where humidity was high. Temperatures were moderate, rarely dropping to the freezing point. The trees on Unga Island were covered with sedimentary material between 11 and 25 million years ago (Eakins 1970). Many reports clearly indicate the advance of Sitka spruce from Afognak Island, across Kodiak Island and toward the Alaska Peninsula (Griggs 1934; Lutz 1963; Murie 1959). Sitka spruce were planted on Unalaska Island in the Aleutians in 1805, and have produced cones and seedlings. There is great disagreement, however, as to whether such forests have existed in the Aleutians in the past. The forest edge on the Peninsula is advancing at a rate of approximately a mile per century. If current conditions prevail, these trees might, in time, cover the entire Alaska Peninsula. The biotic environment of the Western Gulf is presently, and has always been, in a state of constant change. 394 Literature Cited Alaska Department of Fish and Game. 1972. 1971 Alaska Catch and Production: Commercial Fisheries Statistics. Statistical Leaflet No. 23. Juneau. 1973a. Alaska's Wildlife and Habitat. Anchorage. 141 p. 1973b. Kodiak Area Management Report, 1972. Kodiak. Alexander, W.B., 1954. Birds of the ocean. G.P. Putnam's Sons, New York, 306 p. Alton, Miles and Ron Nicholl. 1973. "Untapped Alaskan Pollock Stocks." National Fisherman Yearbook 1973. pp. 56-57, 128-129. Alverson, D.L., A.T. Pruter, and L.L. Ronholt. 1964. A Study of Demersal Fishes and Fisheries of the Northeastern Pacific Ocean. H.R. MacMillan Lecture in Fisheries. Institute of Fisheries. University of British Columbia, Vancouver. American Ornithologist's Union. 1957. The A.O.U. Check-list of North American Birds. 5th ed. A.0.U., Port City Press, Baltimore, Md., 691 p. Armstrong, Robert H. 1969. ''The Sea-Run Dolly Varden in Alaska." Wildlife Notebook Series. Alaska Department of Fish and Game, Juneau. Arnold, Lee W. 1948. "Observations on Populations of North Pacific Pelagic Birds." Auk. 65:553-558. Ashmole, N.P. 1971. "Sea Bird Ecology and the Marine Environment." In: Ayian Biology. Donald S. Farhar and James King, ed. Academic Press, New York. Baily, Edgar P., and Glenn H. Davenport. 1972. "Die-off of Common Murres on the Alaska Peninsula and Unimak Island." The Condor. 74(2):215-219. Baker, R.C., F. Wilke and C.H. Baltzo, 1970. The Northern Fur Seal. U.S. Bureau of Commercial Fish. Circ. 336. 20 p. Barr, Loyis, and Roland McBride. 1967. Surface-to-Bottom Pot Fishing for Pandalid Shrimp. U.S. Fish and Wildlife Service. Special Scientific Report-Fisheries No. 560. Bartonek, J.C., J.G. King and H.K. Nelson. 1971. "Problems Confronting Migratory Birds in Alaska." Transactions of the 36th North American Wildlife and Natural Resources Conference. Wildlife Mem't. Inst. Washington, D. C. pp. 345-361. 395 Bartonek, J.C. and Leroy W. Sowl. 1972. "Birds." In: Final Environmental Impact Statement Proposed Trans-Alaska Pipeline. Vol. 3. National Technical Information Service, U.S. Dept. of Commerce. Springfield, Va. Barysheva, K.P. 1965. '"Cumacean Fauna of the Gulf of Alaska." In: Soviet Fisheries Investigations in The Northeast Pacific. Part IV. P.A. Moiseev, ed. Transl. by Israel Program for Scientific Trans- lations, Jerusalem 1968. pp. 70-75. Bedard, J., 1969. "Feeding of the Least, Crested, and Parakeet Auklets around St. Lawrence Island Alaska." Can. J. Zool., 47:1025-1050. Bell, F. Heward. 1972. "The Pacific Halibut - A Managed Resource." Section 18. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report No. R72-23. Bell, F. Heward, and Gilbert St. Pierre. 1970. The Pacific Halibut. International Pacific Halibut Commission. Seattle, Wa. Technical Report No. 6. 24 p. Belopolskii, L.O. 1957. Ecology of sea colony birds of the Barents Sea. Izd-vo AN SSSR. Moskva-Leningrad. (Transl. into English by IPST, Jerusalem, 1961, 346 p. translated). Bent, A.C. 1938. Life Histories of North American Birds of Prey (Part two). U.S. National Museum, Bull. 170. Bishop, R.H. 1967. Reproduction, Age Determination and Behavior of the Harbor Seal, Phoca vitulina L., in the Gulf of Alaska. M.S. Thesis. University of Alaska, Fairbanks. Brown, Ralph B. 1971. The Development of the Alaskan Fishery for Tanner Crab, Chionecetes speices, with Particular Reference to Kodiak Area, 1967-1970. Alaska Department of Fish and Game, Juneau. Informational Leaflet 153. Brown, Ralph B. and Guy C. Powell. 1972. "Size at Maturity in the Male Alaskan Tanner Crab, Chionoecetes bairdi, as Determined by Chela Allometry, Reproductive Tract Weights, and Size of Precopulatory Males." J. Fish. Res. Bd. Canada 29: 423-427. Buck, Eugene H. 1973. Alaska and the Law of the Sea -- National Patterns and Trends of Fishery Development in the North Pacific. Arctic Environmental Information and Data Center, University of Alaska, Anchorage. 65 p. Burgner, Robert L., Charles J. DiCostanzo, Robert J. Ellis, George Y. Harry, Jr., Wilbur, L. Hartman, Orra E. Kerns, Jr., Ole A. Mathisen, and William F. Royce. 1969. "Biological Studies and Estimates of Optimum Escapements of Sockeye Salmon in the Major River Systems in Southwestern Alaska." Fishery Bulletin. 67(2):405-458. 396 Burner, Clifford. 1963. Pacific Salmon. U.S. Fish and Wildlife Service. Fishery Leaflet 563. Burns, John J. 1970. "Remarks on the Distribution and Natural History of Pagophillic Pinnipeds in the Bering Chukchi Seas. Journal of Mammalogy 51(3):445-454. Burt, William H., and Richard P. Grossenheider. 1964. A Field Guide to the Mammals. Houghton, Mifflin and Co., Boston. 284 p. Butler, T.H. 1967. Shrimp Exploration and Fishing in the Gulf of Alaska and Bering Sea. Fisheries Research Board of Canada. Technical Report No. 18. Cade, Tom J. 1960. "Ecology of the Peregrine and Gyrfalcon Popualtions in Alaska." University of California Publication in Zoology. 63(3) :151-290. Capps, Stephen R. 1934. "Notes on the Geology of the Alaska Peninsula and Aleutian Islands." U.S. Geological Survey Bull. pp. 141-187. Clark, W.K. 1957. "Seasonal Food Habits of the Kodiak Bear." Trans. N. Amer. Wildl. Conf. 22:145-151. Cooney, Robert T. 1972. "A Review of the Biological Oceanography of the Northeast Pacific Ocean." Section 3. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Cottam, Clarence. 1939. Food Habits of North American Diving Ducks. U.S. Dept. Agr. Tech. Bull. No. 643. and Phoebe Knappen. 1939. '"'Food of some uncommon North American Birds." Auk 56(2):138-169. Cupp, Easter, E. 1937. "Seasonal Distribution and Occurrence of Marine Diatoms and Dinoflagellates at Scotch Cap, Alaska." Scripps Inst. of Oceanography, Technical Series. 4(3):71-100. Doi, T. 1971. Diagnosis Method of sperm Whale Population. Bull. Takai Regional Fish. Res. Lab. No. 66. Drent, R.H. 1965. "Breeding Biology of the Pigeon Guillemot, Cepphus columba." Ardea, Magazine of the Dutch Ornithological Union. 53(3/4) :99-160. Druehl, L.D. 1970. "The Pattern of Laminariales Distribution in the Northeast Pacific." Phycologia 9:237-247. Eakins, G.R. 1970. A Petrified Forest on Unga Island, Alaska. Alaska Division of Mines and Geology, Dept. of Natural Resources. Special Report No. 3. 397 Eldridge, Peter. 1972a. "The King Crab Fisheries in the Gulf of Alaska." Section 12. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. 1972b. "Tanner Crab Fishery in the Gulf of Alaska." Section 13. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Eyerdam, Walter Jacob. 1960. "Mollusks and Brachiopods from Afognak and Sitkalidak Islands, Kodiak Groups, Alaska." The Nautilus. 74(2) :41-46. The Faculty of Fisheries. 1957. "1955 Cruise of the 'Oshoro Maru' to the Bering Sea and Northern North Pacific (NORPAC Project)." In: Data Record of Oceanographic Observations and Exploratory Fishing. No. 1. Hokkaido University, Hakodate, Japan. pp. 67-132. 1961. "The 'Oshoro Maru' Cruise 46 to the Bering Sea and North Pacific in June-August 1960." In: Data Record of Oceanographic Observations and Exploratory Fishing. No. 5. Hokkaido University, Hakodate, Japan. pp. 51-262. 1965. "The 'Oshoro Maru' Cruise 9 to the Northern Pacific and Bering Sea in June-August 1964."" In: Data Record of Oceanographic Observations and Exploratory Fishing. No. 9. Hokkaido University, Hakodate, Japan. pp. 219-314. 1966. "The 'Oshoro Maru' Cruise 14 to the Northern North Pacific and Bering Sea in May-August 1965."" In: Data Record of Ocean- graphic Observations and Exploratory Fishing. No. 11. Hokkaido University, Hakodate, Japan. pp. 165-262. 1967. "The 'Oshoro Maru' Cruise 19 to the Northern North Pacific and Bering Sea in June-August 1966." In: Data Record of Oceanographic Observations and Exploratory Fishing. No. ll. Hokkaido University, Hakodate, Japan. pp. 165-262. 1968. "The 'Oshoro Maru' Cruise 24 to the Northern North Pacific and Bering Sea in June-August 1967."" In: Data Record of Ocean- graphic Observations and Exploratory Fishing No. 12. Hokkaido University, Hakodate, Japan. pp. 292-420. 1969. "The 'Oshoro Maru' Cruise 28 to The Northern North Pacific, Bering Sea and The Gulf of Alaska." In: Data Record of Ocean- graphic Observations and Exploratory Fishing. No. 13. Hokkaido University, Hokodate, Japan. pp. 1-136. 1972. "The 'Oshoro Maru' Cruise 37 to The Northern North Pacific, Bering Sea and The Gulf of Alaska in June-August 1970." In: Data Record of Oceanographic Observations and Exploratory Fishing. No. 15. Hokkaido University, Hokodate, Japan. pp. 1-96. 398 Falla, R.A., R.B. Simpson, and E.G. Turbott. 1966. A Field Guide to the Birds of New Zealand and outlying islands. Collins, London. 256 p. Fay, L.F. 1972. United States and Canada Halibut Catches. (maps) Prepared for Atlantic-Richfield Co. Feder, Howard M., and George Mueller. 1972. "The Intertidal Region of the Gulf of Alaska." Section 4. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Federal Water Quality Administration. 1970. Kodiak Oil Pollution Incident February-March 1970. Summary Report. mimeo. Fisher, J., 1952. The Fulmar. Collins, London, 496 p. Fisheries Research Institute. 1971. The Effects of the Disposal of Salmon Cannery Waste on The Marine Environment Adjacent to Some Kodiak Islands Canneries. University of Washington, Seattle. 44 p. Food and Agriculture Organization of the United Nations. 1972. Atlas of the Living Resources of the Seas. Rome. Forrester, C.R., and D.F. Alderdice. 1973. Laboratory Observations on Early Development of the Pacific Halibut. International Pacific Halibut Commission. Technical Report No. 9. Fox, William W., Jr. 1972. "Shrimp Resources of the Northeastern Pacific Ocean." Section 15. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Gabrielson, Ira N., and F.C. Lincoln. 1959. Birds of Alaska. Wildl. Mgmt. Inst., Washington, D. C. 922 p. Gasser, G.W. 1952. "The Grasses of Alaska." In: Science in Alaska. Proc. Third Alaska Sci. Conf., Fairbanks. Gray, George W. Jr., and Guy C. Powell. 1966. "Sex Ratios and Dis- tribution of Spawning King Crabs in Alitak Bay, Kodiak Island, Alaska (Decapoda Anomura, Lithodidae)." Crustaceana, 10(3): 303-309. Gray, G.W., R.S. Roys and R.J. Simon. 1965. Development of the King Crab Fishery off Kodiak Island. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet No. 52. Griggs, Robert F. 1934. "The Edge of the Forest in Alaska and the Reasons for its Position." Ecology. 15(2):80-96. 399 . Gulland, John A., ed. 1972. The Fish Resources of the Ocean. Ltd., Fishing News (Books) London. Hanson, H.C. 1951. "Characteristics of Some Grassland, Marsh, and Other Plant Communities." Ecological Monographs. 21(4):317-378. Hartman, Wilbur, and Cahrles Y. Conkle. 1961. "Fecundity of Red Salmon at Brooks and Karluk Lakes, Alaska." U.S. Fish and Wild- life Servce. Fishery Bulletin 180.61. Hartman, W.L., W.R. Heard, and B. Drucker. 1967. "Migratory Behavior of Sockeye Salmon Fry and Smolts." J. Fish. Res. Bd. Canada 24(10) : 2069-2099. Hartt, A.C., M.B. Dell, and S.B. Mathews. 1965. "Tagging Studies." International North Pacific Fisheries Commission Annual Report 1964. pp. 81-91. Hartt, A.C., L.S. Smith, and M.B. Dell. 1966. "Tagging and Sampling." International North Pacific Fisheries Commission Annual Report 1965. pp. 72-82. Hayes, Murray L., and Donald T. Montgomery. 1963. Movements of King Crabs Tagged and Released in Shumagin Islands Area 1957-62. U.S. Fish and Wildlife Service. Special Scientific Report-Fisheries No. 458. Haynes, Evan, and Carl Lehman, eds. 1969. Minutes of the Second Alaskan Shellfish Conference. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet 135. Haynes, Evan and Jerry McCrary. 1967. Minutes of the First Alaskan Shellfish Conference, May 23-26, 1967. Alaska Dept. of Fish and Game, Informational Leaflet No. 106. Hemming, James E. 1971. The Distribution and Movement Patterns of Caribou in Alaska. Alaska Department of Fish and Game, Wildlife Tech. Bull. No. 68. 60 p. Hennick, Daniel P. 1970. "Reproductive Cycle, Size at Maturity, and Sexual Compostion of Commercially Harvested Weathervane Scallops (Patinopecten caurinus) in Alaska." J. Fish., Res. Bd. Canada ee See 27: 2112-2199. Hennick, Daniel P. 1973. Sea Scallop, Patinopecten caurinus, Investigations in Alaska. Commercial Fisheries Research and Development Act Completion Report 5-23-R. Alaska Department of Fish and Game, Juneau. Hitz, Charles R. and Robert R. French. 1965. "Occurrence of Pomfret (Brama japonica) in the Northeastern Pacific Ocean. Fishery Industrial Research 3(1):1-7. Hitz, Charles R., and Warren F. Rathjen. 1965. "Bottom Trawling Surveys of the Northeastern Gulf of Alaska. Summer and Fall of 1961 and Spring of 1962."" Commercial Fisheries Review. 27(9):1-15. Hood, D.W., J.J. Goering, J.J. Kelley, R. Barsdate, P. Kinney, G.D. Sharma, P. McRoy, W. Shields, D. Brickell, J. Groves and L. Longerich. 1971. Oceanography of the Bering Sea. Phase I. Turbulent Upwelling and Biological Productivity Mechanisms in the Southeastern Bering Sea and Aleutian Islands. Institute of Marine Science, University of Alaska, Fairbanks. Report R71-9. 212 p. Hulten, Eric. 1973. Flora of the Aleutian Islands. Stockholm, Sweden. 397 p. 1960. Flora of the Aleutian Islands and Westernmost Alaska Peninsula with Notes on the Flora of Commander Islands. Second Ed., Vol. 1. Weinsh. Bergstr. 1968. Flora of Alaska and Neighboring Territories. Stanford University Press, Palo Alto, California 1008 p. International North Pacific Fisheries Commission. 1961-1970. Statistical Yearbooks. Vancouver, B.C. International Pacific Halibut Commission. 1964. Catch Records of a Trawl Survey Conducted by the International Pacific Halibut Commission Between Unimak Pass and Cape Spencer, Alaska From May 1961 to April 1963. No. 36. Seattle, Washington. 524 p. 1973. Annual Report 1972. Seattle, Washington. 36 p. Ivanov, B.G. 1964. "Some Data on The Biology of Shrimp in the Western Part of the Gulf of Alaska." In: Soviet Fisheries Investigations in _the Northeast Pacific. Part I. P.A. Moiseev, ed., Transl. From Russian by Israel Program for Scientific Translations, Jerusalem. 1968. pp. 218-230. Ivanov, B. 1969. "The Biology and Distribution of the Northern Shrimp, Pandalus borealis Kr., in the Bering Sea and the Gulf of Alaska." FAO Fish. Rept. 57(3):800-810. Jackson, Peter B. and Kenneth R. Manthey. 1969. Composition of Kodiak Commercial King Crab Catch. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet 137. Jacques, F.L. 1930. "Water Birds Observed on the Arctic Ocean and the Bering Sea, in 1928." Auk. 47:353-366. Joint Federal-State Land Use Planning Commission for Alaska. 1973. Major Ecosystems of Alaska (map). Anchorage. Jones, R.D., 1972. Izembek National Wildlife Refuge. Narrative Report. U.S. Bureau of Sport Fisheries and Wildlife. Cold Bay, Alaska. 26 p. 401 Kasahara, Hiroshi. 1961. Fisheries Resources of the North Pacific Ocean. Part 1. H.R. MacMillian Lecture in Fisheries. Institute of Fisheries, University of British Columbia, Vancouver. Kenyon K.W. 1962. "History of the Steller Sea Lion at the Pribilof Islands, Alaska." J. Mammal. 43:68-75. Kenyon, Karl W. 1969. The Sea Otter in the Eastern Pacific Ocean. U.S. Fish and Wildlife Service North Am. Fauna Series No. 68. 352 p. Kenyon, Karl W. 1971. "Status of Marine Mammals in the Eastern North Pacific Ocean." In: Final Environmental Impact Statement. Pro- osed Trans-Alaska Pipeline. National Technical Information Service. U.S. Dept. of Commerce, Springfield, Va. Kenyon, K.W. and D.W. Rice. 1961. "Abundance and Distribution of the Steller Sea Lion." J. Mammal. 42:223-234. Kingsbury, Alan P. and Kenneth E. James. Abundance and Composition of King Crabs in the Alitak and Kaguyak Bay Areas During April and June, 1970. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet 152. Kodolov, L.S. 1970. '"Squids of the Bering Sea."" In: Soviet Fisheries Investigations in the Northeast Pacific. Part V. P.A. Moiseev, ed. Israel Program for Scientific Translations, Jerusalem 1972. pp. 157-160. Kozlova, E.V. 1957. Fauna of the U.S.S.R. Birds. v. 2(3), Charadriiformes, suborder Alcae. New Ser. No. 65 Zool. Inst., Acad. of Sci., U.S.S.R., Moscow and Leningrad. (Transl. into English by IPST, Jerusalem. 140 p. translated). Kuroda, N. 1955. "Observation on Pelagic Birds of the Northwest Pacific." Condor. 57:290-300. Kuroda, N. 1960a. "Analysis of Seabird Distribution in the Northwest Pacific Ocean." Pacific Science, 14: 55-67. Kuroda, N. 1960b. "Notes on the Breeding Seasons in the Tubinares (Aves)."" Jap. J. Zool., 12:449-464. Larkins, Herbert A. 1964. "Some Epipelagic Fishes of the North Pacific Ocean, Bering Sea, and Gulf of Alaska." Transactions of the American Fisheries Society. 93(3):286-290. LeBrasseur, R.J. 1965. Biomass Atlas of Net Zooplankton in the Northeastern Pacific Ocean, 1956-1964. Fisheries Research Board of Canada. Manuscript Report Series (Oceanographic and Limnological) No. 201. 402 LeBrasseur, R. 1970. Larval Fish Species Collected in Zooplankton Samples from the Northeastern Pacific Ocean, 1956-1959. Fisheries Research Board of Canada. Technical Report No. 175. Lensink, C.J. 1960. "Status and Distribution of Sea Otters in Alaska." J. Mammal. 41(2):172-182. Lisovenko, L.A. 1964. "The Distribution Of The Larvae Of Rockfish (Sebastodes Alutus Gilbert) In the Gulf of Alaska." In: Soviet Fisheries Investigations in The Norhteastern Pacific Ocean. Part III. P.A. Moiseev, ed. Transl. by Israel Program for Scientific Translations. Jerusalem 1968. pp. 217-225. Lutz, H.J. 1963. History of Sitka Spruce Planted in 1805 at Unalaska Island, Alaska, by the Russians. Northern Forest Experiment Station, U.S. Forest Service, Juneau. Lyubimova, T.G. 1964. "Biological Characteristics of the School of Pacific Rockfish (Sebastodes alutus G.) in the Gulf of Alaska." In: Soviet Fisheries Investigations in the Northeast Pacific. Part III. P.A. Moiseev, ed. Transl. by Israel Program for Scientific Translations. Jerusalem 1968. pp. 208-216. MacKay, Donald C.G. 1942. The Pacific Edible Crab, Cancer magister. Fisheries Research Board of Canada. Bulletin 62. Marine Adivsers, Inc. 1971. Oceanographic Investigations Relating to Sewage Outfall Site Selection at Kodiak, Alaska. Solana Beach, California 44 p. Mathisen, 0.A., and R.J. Lopp. 1963. Photographic Census of the Steller Sea Lion Herds in Alaska, 1956-1958. U.S. Fish and Wildlife Service. Special Scientific Report-Fisheries. No. 424. 20 Pp. Matthews, L. Harrison. 1968. The Whale. Simon and Schuster, New York. 288 p. Mayer, David L. 1972. "Synopsis of Biological Data on the Dungeness Crab, Cancer magister (Dana 1852), with Emphasis on the Gulf of Alaska." Section 14. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, Fairbanks. Report R72-23. McHugh, J.L. 1955. "Distribution of Black-footed Albatross (Diomedea nigripes) in the North Pacific Ocean." Yanashina's Inst. Ornithol. Zool., Misc. Rep., 3:239-246. 1969. "The United States and World Whale Resources." Bioscience. 19:1075-1078. McLaughlin, P.A., and J.F. Hebard. 1959. Stomach Contents of The Bering Sea King Crab. U.S. Fish and Wildl. Serv. Spec. Sci. Rept. - Fish. No. 291. 403 McMullen, John C. 19767a. A Preliminary Study of King Crab (Paralithodes camtschatica) Ocean Reproduction and the Delineation of the Kodiak District Continental Shelf Environmental Zones. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet 112. 1967b. Some Aspects of the Life History of Razor Clams Siliqua patula (Dixon), in Cook Inlet, Alaska. Alaska Department of Fish and Game, Juneau. Informational Leaflet 110. 1967c. King Crab, Paralithodes camtschatica (Tilesius), Offshore Breeding Study on Marmot Flats, Kodiak Island, Spring of 1967. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet 112. McMullen, John, and Harvet T. Yoshihara. 1970. The King and Tanner Crab Fishery of the Alaska Peninsula - Aleutian Islands Management Area, 1969-1970. Alaska Dept. of Fish and Game, Juneau. Informational Leaflet 148. McRoy, C. Peter. 1968. "The Distribution and Biogeography of Zostera marina (Eelgrass) in Alaska." Pacific Science. 22(4):505-514. 1970. "Standing Stocks and other Features of Eelgrass (Zostera marina). Populations on the Coast of Alaska."" J. Fish. Res. Bd. Canada. 27:181-1821. 1971. "Marine Plant Resources of Alaska."" The Northern Engineer. 2(4):15-16. » John J. Goering, David C. Burrell, Mary Belle Allen, and J. Brian Mattews. 1969. Coastal Ecosystems of Alaska. Institute of Marine Science, University of Alaska, Faairbanks. mimeo, 38 p. » John J. Goering, and William E. Shiels. 1972. "Studies of Primary Production in the Eastern Bering Sea." In: Biological Oceanography of the Northern North Pacific Ocean. A. Yositada Takenouti et al., eds. pp. 199-216. Idemitsu Shoten, Tokyo, Japan. Meach, L. David. 1970. The Wolf: The Ecology & Behavior of an Endangered Species. The Natural History Press, Garden City, N.Y. 384 p- Mizue, K., and K. Yoshida. 1965. "On the Porposies Caught by the Salmon Fishing Gill-Net in Bering Sea dn the North Pacific Ocean." Bull. Faculty Fisheries Nagasak, Univ. 19:1-36. Mizue, K., K. Yoshida and A. Takemura. 1966. "On the ecology of the Dall's Porpoise in Bering Sea and the North Pacific Ocean." Bull. Faculty of Fish. Nagasaki University. 21:1-21. Moiseev, P.A. 1964. "Some Results of the Work of the Bering Sea Expedtion." In: Soviet Fisheries Investigations in the Norhteast Pacific. Part III. P.A. Moiseev, ed. Trans. by Israel Program for Scientific Translations, Jerusalem 1968. p. 1-21. 404 Murie, Olaus J. 1959. Fauna of the Aleutian Islands and the Alaska Peninsula. U.S. Fish and Wildlife Service. North American Fauna No. 61. 406 p. Nakamura, T. 1963. "Distribution of the Black-footed Albatorss (Diomedea nigrippes) in the North Pacific Ocean." Yanashina's Inst. Ornithol. Zool., Misc. Rep., 3:239-246. Nanamio Biological Station. Undated. "Pacific Edible Crab." Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. Undated. "Soles and Flounders of the Pacific." Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. Undated. "Coho Salmon." Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. 1966b. "The Pacific Gray Cod." Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. 1966c. "The Pacific Herring." Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. 1966d. The Pacific Halibut."' Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. 1967. "Chum Salmon." Fisheries Fact Sheet. Fisheries Research Board of Canada, Nanaimo, B.C. National Marine Fisheries Service. Undated. Alaska NMFS Exploratory Fishing Drags. Kodiak and Seattle. Various months. Monthly Summary of Foreign Fishing Activities off Alaska. Juneau. Nishiwaki, M. and C. Handa. 1958. "Killer Whales Caught in the Coastal waters off Japan for Recent 10 years." Sci. Rep. Whales Res. Inst. 13:85-96. NORPAC Committee. 1960. Oceanic Observations of the Pacific: 1955, The NORPAC Atlas. Univ. of Calif. Press and Univ. of Tokyo Press. Berkeley and Tokyo. Nosho, Terry Y. 1972. "The Claam Fishery of The Gulf of Alaska." Section 17 In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Nybakken, J.W. 1969. Pre-earthquake Intertidal Ecology of Three Saints Bay, Kodiak Island, Alaska. Biol. Papers of the University of Alaska. No. 9. 117 p. Odum, Eugene P. 1963. Ecology. Holt, Rinehart and Winston, New York. 152 p. Omura, H., and S. Ohsumi. 1971. "Researches on Whale Biology of Japan with Special Reference to the North Pacific Stocks." Paper read at Conf. on Biology of Whales, U.S. International Biological Program, Luray, Virginia. Orr, R.T. 1970. Animals in Migration. Macmillan Co. New York, N.Y. 303 p. Osgood, W.H. 1904. A Biological Reconnaissance of the Base of the Alaska Peninsula. U.S. Fish and Wildlife Service. North American Fauna Series No. 24. Paddock, Dean. 1971. "The Rainbow Trout in Alaska." Wildlife Note- book Series. Alaska Department of Fish and Game, Juneau. Pearson, T.H. 1968. "The Feeding Biology of Sea-bird Species Breeding on the Farne Islands, Northumberland." J. Animal Ecol., 373;521-552. Peterson, R.T. 1961. A Field Guide to Western Birds. Riverside Press, Boston. 366 p. Pike, G.C. and I.B. MacAskie. 1969. Marine Mammals of British Columbia. Fish Res. Bd. Can. Bull. 171. 55 p. Poulin, Vincent A., and Louis A. Gwartney. In press. Growth and Development of Pacific Razor Clams, Siliqua patula (Dixon), on Swikshak Beach. Alaska Department of Fish and Game, Juneau. Informational Leaflet. Powell, Donald E. and Alvin E. Peterson. 1957. Experimental Fishing to Determine Distribution of Salmon in the North Pacific Ocean, 1955. U.S. Fish and Wildlife Service. Special Scientific Report- Fisheries No. 205. Powell, Guy C., and George W. Gray, Jr. 1964. '"'Present Status of the King Crab in Alaska." In: Proceedings of Symposium on Crustacea. Part IV. Powell, Guy C., and Richard B. Nickerson. 1965. "Reproduction of King Crabs, Paralithodes camtschatica (Tilesius)." J. Fish. Res. Bd. Canada 22(1):101-111. Powell Guy C., and Richard E. Reynolds. 1965. Movements of Tagged King Crabs, Paralithodes camtschatica (Tilesius), in the Kodiak Island - Lower Cook Inlet Region of Alaska, 1954-1963. Alaska Department of Fish and Game, Juneau. Informational Leaflet 55. Quast, Jay C., and Elizabeth L. Hall. 1972. List of Fishes of Alaska and Adjacent Waters with a Guide to Some of Their Literature. NOAA Technical Report NMFS SSRF-658. 406 Reeves, J.E. 1972. "Groundfish of the Gulf of Aalska." Section 19. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Rice, D.W. 1968. "Stomach Contents and Feeding Behavior of Killer Whales in the Eastern North Pacific." Norsk Hvalfangsttidende. 2:35-38. Rice, Dale W. 1971. "Whales and Whale Research in the Eastern North Pacific Ocean." In: Proceedings of the Conference on the Biology of Whales. U.S. International Biome Program. Luray, Va. Ricketts, E.F., J. Calvin, and J.W. Hedgpeth. Between Pacific Tides. Stanford University Press, Stanford, California. Rigg, George B. 1915. "The Kelp Beds of Western Alaska." In: Potash from Kelp. Part V. Frank K. Cameron U.S. Department of Agriculture Washington, D.C. Report No. 100. pp. 105-122. Roden, Gunnar I. 1967. Winter Expedition to The Gulf of Alaska. Dept. of Oceanography, University of Washington, Seattle, mimeo. Roelofs, Eugene W. 1964. Further Studies of the Afognak Lake System. Alaska Department of Fish and Game, Juneau. Informational Leaflet 41. Sanger, G.A. 1972a. "Preliminary Standing Stock and Biomass Estimated of Seabirds in the Subarctic Pacific Region." In: Biological Oceanography of the Northern North Pacific Ocean. Hokkaido University, Hokodate, Japan. pp. 589-611. 1972b. "The Recent Pelagic Status of the Short-tailed Albatross." Biological Conservation 4(3):83-87. Sandegren, F.E. 1970. Breeding and Maternal Behavior of the Steller Sea Lion (Eumetopias jubata) in Alaska. M.S. Thesis. Univ. Alaska. No. 12, 138 p. Scammon, C.M. 1874. The marine mammals of the northwestern coast of North America. John H. Carmany and Co. San Francisco. facsimile reprint, 1968. New York 319 p. Scheffer, V.B. 1949. "The Dall Porpoise, Phocoenoides dalli, in Alaska." J. Mammal. 30;116-121. Scheffer, Victor V. 1959. "Invertebrates and Fishes collected in the Aleutians, 1936-38." In: Fauna of The Aleutian Islands and Alaska Peninsula. Olaus Murie. U.S. Fish and Wildlife Service. North American Fauna Series. No. 6l. Scheffer, Victor B. 1972. "Marine Mammals in the Gulf of Alaska." Section 10. In: A Review of the Oceanography and Renewable Resources of The Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. 407 Schiller, Everett L., and Robert Rausch. 1956. "Mammals of the Katmai National Mounment, Alaska." Arctic 9(3):191-201. Schneider, K. 1973. Sea otter distribution and Abuandance. Alaska Department of Fish and Game, Juneau. 6 p. Semenov, V.N. 1965. "Quantitative Distribution of Benthic Fauna of the Shelf and Upper Part of the Slope in the Gulf of Alaska." In: Soviet Fisheries Investigations in the Northeast Pacific. Part IV. P.A. Moiseev, ed. Transl. by Israel Program for Scientific Translations. Jerusalem 1968. pp. 37-69. Serventy, D.L. 1967. Aspects of the Population Ecology of the Short-tailed Shearwater, Puffinus tenuirostris." Proc., XIV Int. Ornithol. Congr.: 165-190. Sheppoard, Douglas. 1972. "The Present Status of the Steelhead Trout Stocks Along the Pacific Coast."" Section 22. In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R72-23. Shevtosov, V.V. 1964. "Quantitative Distribution and Trophic Groups of Benthos in the Gulf of Alaska." In: Soviet Fisheries Investigations in the Northeast Pacific. Part III. P.A. Moiseev, ed. Transl. by Israel Progarm for Scientific Translations. Jerusalem 1968. pp. 150-166. Shubnikov, D.A. 1963. "Data on the Biology of Sablefish of the Bering Sea." In: Soviet Fisheries Investigations in the Northeast Pacific. Part I. P.A. Moiseev, ed. Trans. by Israel Progarm for Scientific Translations, Jerusalem 1968. pp. 287-296. Shuntov, V.P. 1965. "Distribution of the Greenland Halibut and Arrow-Toothed Halibuts in the North Pacific." In: Soviet Fisheries Investigations in the Northeast Pacific. P.A. Moiseev, ed. Part IV, Transl. by Israel Program for Scientific Translations. Jerusalem 1968. pp. 147-156. Storer, Tracy I., and Robert L. Usinger. 1965. General Zoology. McGraw- Hill, San Francisco 740 p. Straty, Richard R. In press. "Ecology and Behavior of Junvenile Sockeye Salmon (Oncorhynchus nerka) in Bristol Bay and the Eastern Bering Sea." In: Oceanography of The Bering Sea. Donald W. Hood and E.J. Kelley (eds). Institute of Marine Sciences, University of Alaska, Fairbanks. Occas. Publ. No. 2. 900 p. Thorsteinson, F.V., R.W. Nelson and D.F. Lall. 1961. Experimental Harvest of the Steller Sea Lion in Alaskan Waters. U.S. Fish and Wildl. Serv., Spec. Sci. Report. Fisheries No. 371. 15 p. Tikhomirov, E.A. 1964. "Distribution and Hunting of the Sea Lion in The Bering Sea and Adjacent Parts of the Pacific."" In: Soviet Fisheries Investigations in The Northeast Pacific. Part III. P.A. Moiseev, ed. Israel Program for Scientific Translations, Jerusalem 1968. pp. 218-285. 408 Turner, L.M. 1886. Contributions to the Natural History of Alaska. Government Printing Office, Washington, D.C. 226 p. Udvardy, M.D.F. 1963. "Zoogeographical Study of the Pacific Alcidae." In: Pacific basin biogeography, 10th Pacif. Sci. Congr., Honolulu, Hawaii, 1961. (edit. J.L. Gressit). Bishop Museum Press, Honolulu. p- 85-111. U.S. Army Corps of Engineers. 1973. Proposed Small Boat Harbor - Kodiak, Alaska. Preliminary draft - environmental impact statement. Alaska District, Anchorage. : U.S. Bureau of Commercial Fisheries. 1965. Fisheries Potential in the Gulf of Alaska and Bering Sea. Exploratory Fishing and Gear Research Base, Seattle. (mimeo) 34 p. 1968. Newsletter. No. 8, July 10. Auke Bay, Alaska. U.S. Bureau of Land Management. 1973. Gulf of Alaska Data Reconnaissance Study. Preliminary draft. Division of Marine Minerals, Anchorage. U.S. Bureau of Sport Fisheries and Wildlife. 1972. Proposed Unimak Island Wilderness, Alaska. Draft environmental statement. (mimeo) Anchorage. U.S. Depts of Agriculture and the Interior. 1972. Bald Eagles in Alaska. Government Printing Office, Washington, D.C. 12 p. U.S.Department of the Interior 1964. Waterfowl Tomorrow. U.S. Government Printing Office. Washington, D. C. 784 p. 1965. Birds of the Kodiak National Wildlife Refuge. Bureau of Sport Fisheries and Wildlife, Anchorage, Alaska. 3 p. 1972. Kodiak National Wildlife Refuge Wilderness Study Report. Bureau of Sport Fisheries and Wildlife, Anchorage. 203 p. 1973. Birds of the Izembek National Wildlife Range. Bureau of Sport Fisheries and Wildlife, Anchorage, Alaska. 4 p. U.S. Senate. 1972. Hearings Before the Subcommittee on Oceans and Atmosphere of the Committee on Commerce, United States Senate, 92nd Congress, Second Session, on S. 685, 1315, 2579, 2369 2871, 3112, 3162, and Amendment 1048, Ocean Mammal Protection. U.S. Government Printing Office, Washington, D.C. Serial No. 92-56. Van Hulle, Frank and John B. Murray. 1972. Inventory and Cataloging of the Sport Fish and Sport Fish Waters in Southwest Alaska. Alaska Dept. of Fish and Game, Juneau. Project F-9-4. Van Hulle, Frank and John B. Murray. 1973. Inventory and Cataloging of the Sport Fish and Sport Fish Waters in Southwest Alaska. Alaska Dept. of Fish and Game, Juneau. Project F-9-5. 409 Viereck, Leslie A. and Elbert L. Little, Jr. 1972. Alaska Trees and Shrubs. U.S. Department of Agriculture Handbook No. 410. Wetmore, Alexander, Herbert Friedmann and others. 1945. "Twentieth Supplement to the American Ornithologists Union Checklist of North American Birds." Auk 62(3):436-449. White, Clayton M., and Heinrich K. Springer. 1965. "Notes on the Gyrfalcon in Western Coastal Alaska." Auk 82(1):104-105. GGG) «COMMERCIAL KING CRAB GROUNDS IDENTIFIED BY GUY C. POWELL COMMERCIAL KING CRAB GROUNDS IDENTIFIED BY DUANE E. PHINNEY Figure A-1. Commercial king crab grounds identified by research and management staff, Division of Commercial Fisheries, Alaska Department of Fish and Game, Kodiak, Alaska (personal communication: Guy C. Powell, Fishery Biologist, June 21, 1974 and Aucust 7, 1974; Duane E. Phinney, Regional Shellfish Coordinator, June 12, 1974). COMMERCIAL TANNER CRAB GROUNDS IDENTIFIED BY GUY C. POWELL {TITD COMMERCIAL TANNER CRAB GROUNDS IDENTIFIED BY DUANE E. PHINNEY yp 20s-- A helt sO fil — ‘ ffl UTS? Figure A-2. Commercial tanner crab grounds identified by research and management staff, Division of Commercial Fisheries, Alaska Department of Fish and Game, Kodiak, Alaska (personal communication: Guy C. Powell, Fishery Biologist, June 21, 1974 and August 7, 1974; Duane E. Phinney, Regional Shellfish Coordi- nator, June 12, 1974). bob C-W HWE) COMMERCIAL DUNGENESS CRAB GROUNDS Figure A-3. Commercial Dungeness crab grounds identified by research and management staff, Division of Commercial Fisheries, Alaska Department of Fish and Game, Kodiak, Alaska (personal communication: Guy C. Powell, Fishery Biologist, June 21, 1974 and August 7, 1974). bor COMMERCIAL SHRIMP GROUNDS Note: Ugak Bay and the southern portion of Sitkalidak Straits are presently closed to commercial shrimp fishing. Figure A-4, Commercial shrimp grounds identified by research and management staff, Division of Commercial Fisheries, Alaska Department of Fish and Game, Kodiak, Alaska (personal ; communication; Peter B. Jackson, Fishery Biologist, July 30, 1974). 60% v-V 410 VIII. SOCIOECONOMICS GENERAL DESCRIPTION OF THE STUDY REGION Overview At the time of the 1970 census, the combined population of the Kodiak and Aleutian Islands Census Divisions was about 17,500 persons. Of this total, about 11,000 persons lived in the Western Gulf region as defined in this study. Most of the population of the region fall into two principal racial groups: whites and Aleuts. The white population is largely concentrated in the military bases and in the city of Kodiak. The population of most other communities in the region is predominantly Aleut. Except for military bases, the only major population center in the Western Gulf of Alaska is Kodiak with a population of 3,800. No other community in the region has a population of more than a few hundred. There are, however, several large military and Coast Guard bases located at Kodiak, Adak, and Shemya. As shown in Table 47, there are over 5,000 military personnel in the region. Compared to a civilian labor force of only 4,000, defense activities clearly have a powerful impact on the economy and society of the region. The effects are particularly pronounced in the Aleutian Islands where military personnel amounts to nearly half the total population and is three times as large as the civilian labor force. The economy of the region is highly dependent upon the government sector, by far the largest employer. The figures in Table 47 show that government employment, civilian and military combined, accounts for 75 percent of total employment in the region. This proportion ranges from nearly 60 percent for the Kodiak Census Division to over 90 percent for the Aleutian Islands Division. Within the Aleutian Islands, government civilian employment alone exceeds total private employment. Throughout the Western Gulf region, the major private industries are commercial fishing and fish processing. The primary commercial fisheries are shellfish (particularly king crab), salmon, and halibut. On the average, fishing and processing accounts for about half of private employment, and during the peak summer months, the proportion is substantially higher. The importance of the fishing industry, with its inherent seasonality, is one factor producing the relatively high unemployment rate in the region. Median family income in the area is significantly lower than the statewide figure of 12,443 dollars in 1970. Income is only moderately lower than average in Kodiak, but in the Aleutians, family income is only about two-thirds the state level. This gap widens if the cost of living is taken into account. For example, the cost of food in Kodiak is approximately 15 percent higher than in Anchorage. Although reliable Table 47 SUMMARY STATISTICS, 1970 KODIAK AND ALEUTIAN ISLANDS CENSUS DIVISIONS Population White Aleut Other Military Personnel Civilian Labor Force Employment Private Goverment Unemployment Rate (percent) Median Family Income Sources: U.S. Bureau of the Census 1970b, Babb 1972. Kodiak Census Division 9,409 7,215 1,582 612 1,491 2,935 2,653 1,754 899 282 9.6 $11,166 Aleutian Is. Census Division 8,057 5,564 1,972 521 3,689 1,088 925 437 488 163 15.0 $8,553 411 Total 17,466 12,779 3,554 1,133 5,180 4,023 3,578 2,191 1,387 445 11.1 $10,253 412 data are not available for the Aleutians, it is not unusual for living costs in comparable remote areas to be 30 to 50 percent higher than in Anchorage. On the other hand, there is a substantial amount of subsistence fishing and hunting in the region which is not reflected either in the income or cost of living figures. In all, the socioeconomic environment of the Western Gulf of Alaska is difficult to analyze comprehensively due to the social, economic, and geographical diversity of the region itself. The aggregate statistics are, of course, dominated by the military-related activities. Because of this, the aggregate statistics in many instances provide poor measures of important aspects of social and economic development. Where possible, special 1970 Census computer runs were used to obtain data on socioeconomic characteristics by race. For Kodiak these runs sometimes make it possible to divide the Census data into two components: the Kodiak Island Borough and the Kodiak Naval Station (now the Kodiak Coast Guard Base). In the following discussion, every effort will be made to present sufficiently detailed data to accurately reflect the area's diversity. Definition of the Study Region Principally, the region consists of Kodiak Island and vicinity and the southern coast of the Alaska Peninsula as far west as Unimak Island. As shown in Figure 162 this geographic area includes all or part of three census divisions: all of the Kodiak Division, part of the Aleutian Island Division, and part of the Bristol Bay Division. The Census Divisions are of considerable importance because they are the areas for which much of the socioeconomic data are reported. Since the economic activity and the population of the Bristol Bay Division is centered well north of the Western Gulf, Bristol Bay is not included in this study. Wherever possible, the data for the Alaska Peninsula and the Aleutian Islands will refer only to those communities within the geographic study area. However, Nelson Lagoon will be treated as part of the study area even though it is on the north side of the peninsula. In terms of social and economic relationships, Nelson Lagoon is clearly a part of the region being studied. Also, in some cases the available data will be for the Aleutian Island Census Division as a whole. The communities within the Western Gulf region are shown on Figure 162 and are listed in Table 48. The list includes all communities reported separately in the 1970 census. A summary description of each of these communities is given in the following section. Major Communities in the Western Gulf Region Kodiak and Vicinity Kodiak, the oldest permanent settlement in Alaska, was founded by the Russians in 1792(?). The city flourished as a sea otter trading 164° 162° 160° 158° 156° 154° 152° T T T 7 3 ( / (~ sf 59° } or od) GOO? 4 selected places in the BRISTOL BAY DIV “z Western Gulf of Alaska as (from U.S. Bureau of IN sr” the Census 1970b). f BS i - cee \ 4 Figure 162. Census divisions and S Cos Ao 2 “9 < 9 Ouzinkie 2% $ ’ ‘odiak ‘Woody Island Naval Reservation Ka 7 7 \ . Shi yh x 7 \\ Jos 7 2 \ 7 ¢ “7 ef \ ge =i KM ” Chignik Lake ito \ VO —/ . 2, \ \ ) \ ~ « pbs Cn Vi fy re pr ae S/d 4 Bo Creer Point 207) Sa De tx seu!” shel, ‘NS 3 ing Cove Harbor ¢ o 78 JX a =e em am BOUNDARY OF STUDY AREA Pavlof Harbor a a 200 —— Se —— —_— ~ S = —, US ee —~S 649] Yo 41 6000 4 —_ 1 1 ! 1 | 164° 162° 160° i Gs L tee 154° — rr 150° Sib 414 Table 48 COMMUNITY SIZE WESTERN GULF OF ALASKA 1970 3000 or more population Population Kodiak 3,798 Kodiak Station 3,052 300-400 population Sand Point 360 200-299 population Cold Bay 256 King Cove 283 Old Harbor 290 Port Lions 227 100-199 population Akhiok 115 Chignik Lake 117 Larsen Bay 109 Ouzinkie 160 25-99 population Belkofski 59 Chignik 83 False Pass 62 Ivanof Bay 48 Kaguyak 59 Karluk 98 Nelson Lagoon 43 Pavlof Harbor 39 Perryville 94 Squaw Harbor 65 Woody Island 41 Source: U.S. Bureau of the Census 1970b. 415 center and by 1860 the community's population of Natives and Europeans numbered 1,500. Beginning in the 1840s the Russians had limited the killing of sea otters to insure a sustained yield. When the United States purchased Alaska in 1867, regulation of the sea otter harvest ceased. As a result, intensive hunting drove the sea otter to near extinction. Kodiak's population and economy declined correspondingly. Between 1890 and 1929 the city's population averaged about 400. Beginning in the 1920s salmon fishing became the dominant force in the economy. Several canneries were built in the Kodiak area and by 1939 the population of the city rose to 864. As early as 1892 the Japanese processed king crab. By 1902 Japanese and Russian floating canneries were operating in Alaskan waters. Since the Americans already had a prosperous salmon fishery, they showed little interest in harvesting king crab. In addition, they could not compete with cheap Japanese labor, lacked crab canning and harvesting technology, and knew little about the biology of the species. Americans were starting to investigate king crab production when World War II intervened. Prior to the war the Navy began to worry that Japan might attack the continental United States via the Aleutian Islands. To avert such a threat, they began a military buildup in Alaska. Kodiak was chosen as a site for one of the first bases. In August 1939, 2,500 civilian construction workers, an Army garrison of 7,600, and more than 700 Navy personnel poured into Kodiak to begin construction of Kodiak Naval Station. The military activities strengthened Kodiak's economy and by the end of the war, the population in the city had increased to 4,000. After the war the salmon industry in the area was on the decline. In 1948 a Kodiak resident built a small floating cannery and became the first American to process king crab commercially. In 1950 the Koidak area catch was only 29.5 metric tons, but its potential was soon recognized and the industry expanded tremendously. By 1960 the catch was 41,250 metric tons. In March of 1964 in the midst of its king crab prosperity, Kodiak was hit by an earthquake and devastating seismic waves. The waterfront seafood processing plants were severely damaged and much of the fishing fleet was lost. More than 40 percent of the downtown business areas was destroyed. The losses in the city of Kodiak alone totaled more than 22 million dollars, but with the assistance of federal loans and grants, the rebuilding of Kodiak was under way within two months. The construction activity helped offset the temporary loss of employment in other industries. The modernization of the community in the post- earthquake period and the diversification in the fishing industry helped stablize Kodiak's economy over the longer run. 416 Between 1960 and 1970, despite a reduction in military activity, Kodiak's population increased to 3,800 (U.S. Bureau of the Census 1970b). Today Kodiak is by far the largest city in the Western Gulf of Alaska. It is the trade, service, government, and transportation center for Kodiak Island. King crab production has declined in recent years, but the harvest of a variety of other seafood has continued Kodiak's prosperity. Woody Island, located one mile from the city, is considered part of the Kodiak urban area. The population of Woody Island has declined markedly from 111 in 1950 to 41 in 1970. A few homes, a Baptist mission, a Federal Aviation Agency communications stations, and a small school are now the only facilities on the island. Transportation to Kodiak is provided by a converted fishing boat when weather permits, and during bad weather, the island is effectively isolated (Tryck, Nyman and Hayes 1968). The Kodiak Coast Guard Base is located at Kodiak Station about four miles southwest of the city of Kodiak. Prior to its transfer on July 1, 1972, this facility was the Kodiak Naval Station. The base provides logistic support to Coast Guard units in the area which includes three ships, an air station, a communications station, and a LORAN (long-range aid to navigation) station. The base lends support to other vessels on patrol in Alaska and ships of the National Atmospheric and Oceanographic Administration. Assistance in military and civilian search and rescue missions is also available. The 1970 Census reported 3,052 military personnel and their dependents living on the naval base. In October 1973 the Coast Guard information officer said that the population on the base had been reduced to 2,300 persons. Housing is provided for military personnel and dependents. Recreational, commissary, and medical services are provided by the Coast Guard. The Coast Guard has a five-year plan for modernization and construction on the base. They anticipate that the number of personnel stationed at the base will gradually increase. Chiniak Air Force Station, located southeast of Kodiak, is connected with the Kodiak urban area by a 45 mile road. Of the 120 personnel stationed at the Chiniak facilities, approximately one-third live in Kodiak or outlying areas with their families (Tryck, Nyman and Hayes 1968). : Kodiak Island Villages Six villages, inhabited primarily by Natives, are also part of the Kodiak Island Borough: Port Lions, Ouzinkie, Old Harbor, Akhiok, Larsen Bay, and Karluk. Between 1960 and 1970 all these communities lea. Parker, Public Information Officer, Kodiak Coast Guard Base, October 1973. Personal communication. 2Ibid. 417 increased in size with the exception of Ouzinkie which experienced a 25 percent decline. The combined growth rate for these villages during the 1960s was 15 percent. Of 1,056 persons living in the Kodiak villages, only 130 (12 percent) are white (Evans and Rybeck 1973). Nearly all of the Natives are of Aleut ancestry according to the 1970 Census. The economy of all of these villages is heavily dependent upon the fishing industry which offers nearly all of the opportunities for employment and cash income. Processing plants are located in or near all of the villages. These plants handle a variety of seafood resources found in abundance near the villages, including salmon, shrimp, scallops, and several varieties of crab. In addition to commercial fishing, subsistence fishing and hunting are important pursuits in these villages. There is a small sawmill at Ouzinkie and plans to build another at Port Lions to harvest local timber stands. However, the total employment in lumber is expected to be minor compared to fishing. There is a limited amount of tourism employment--primarily guided hunting and fishing trips--but recreational potential near these outlying villages remains largely undeveloped. The communities closest to Kodiak (Port Lions, Ouzinkie, and Old Harbor) have relatively modern housing and offer a wider range of facilities and services than are found in most Alaskan villages. Village modernization in these areas was primarily the result of post-earthquake construction. The new village absorbed the populations of Afognak and Port Wakefield which were heavily damaged and deemed unsafe for continued habitation. The villages of Akhiok, Kauluk and Larsen Bay, which are more remote from Kodiak, suffered relatively minor earthquake damage. Thus, there was little need for major rebuilding. In general, these villages have poor housing, a low level of basic services and facilities, and living conditions are much more primitive than those found elsewhere on the island (Tryck, Nyman, and Hayes 1968). None of the borough villages has a road connection with Kodiak, although there are plans to build roads to the city from Port Lions and Ouzinkie. All villages are linked to Kodiak via regularly scheduled air service. In addition, fishing boats are commonly used to transport passengers and goods. Port Lions is also served by the Alaska State Ferry Tustumena which provides connections with Kodiak and Homer. Seafood canneries and processing plants are located at Port Williams, Port Bailey, Uganik Bay, Zachar Bay, Uyak Bay, and Lazy Bay. During the fishing season as many as 50 to 100 persons live and work at these plants. At the end of the season the facilities close and nearly everyone leaves, except a few maintenance personnel (Tryck, Nyman and Hayes 1968). 418 Unspecified Places on Kodiak Island In 1970, 9,409 persons were accounted for in the populations of the city of Kodiak, Woody Island, Kodiak Station, and the outlying villages. This leaves 1,460 persons who were not given a particular location (Table 49). The Census ennumeration maps do not show the boundaries of the districts which hold these persons, but most of the general areas were near the city of Kodiak. Additionally, since more than 80 percent of this residual population is white, it is likely that many of these persons live in the vicinity of the city of Kodiak (Table 49). Sand Point Sand Point, with a population of 360, is the largest village in the Alaska Peninsula portion of the Western Gulf (U.S. Bureau of the Census 1970b). From 1880 until 1950 the population of Sand Point grew very slowly. Then the area's fishery expanded and the population of Sand Point grew rapidly. Between 1950 and 1960 the population increased by 137 percent (U.S. Bureau of the Census 1960). Much of this growth is attributable to migration from other Western Gulf communitites with fewer economic opportunities. Except for a brief period of placer gold mining during the early part of this century, Sand Point's economy has been dominated by the fishing industry (Alaska Consultants, Inc. 1970). The first canneries were built there in the late 1880s to process cod. Later, when the cod were fished out, salmon became the primary fishery resource. Since World War II, king crab, tanner crab, and halibut have been harvested and processed at Sand Point. Today Sand Point's economy is entirely dependent on two fish processors. One freezes crab, halibut and salmon. The other is a cannery for king crab. Salmon fishing is also important to Sand Point's economy, but most of the local harvest is collected by cannery tenders and taken to King Cove for processing. Since 1966 king crab catches in the Sand Point area have declined drastically. This segment of the fishery has changed from a year-round opearation to a seasonal one. Increased seasonality in the harvesting of king crab has been offset to some extent by a shift to other species such as tanner crab. Sand Point is a major halibut port. Halibut vessels fishing in the Bering Sea or in the Aleutian Islands must have their licenses validated and catches recorded at Sand Point before sale. In addition, the regulations require halibut vessels to lay over for eight days following a fishing run. After this time their licenses can be validated for the next trip (International Pacific Halibut Commission 1972). The halibut fleet layovers during the fishing season (which extends from April to October) provide a significant inflow of money into the local economy. Although the villages of Cold Bay, King Cove, Port Moller, Squaw Harbor, Perryville, and Belkofski are all located within a 160 km. radius of Sand Point, the community is relatively isolated from Alaska's Table 49 POPULATION BY RACE AND SEX--BY COMMUNITY WESTERN GULF OF ALASKA 1970 ALL_ RACES WHITE NEGRO PLACE Male Female Total M F Tot M F Tot Alaska Peninsula Belkofski 31 28 59 2 3 5 1 0 1 Chingnik 44 39 83 7 9 16 0 0 0 Chignik Lake 62 $5 117 1 1 2 0 0 0 Cold Bay 193 63 256 166 48 214 9 0 9 False Pass 36 26 62 4 0 4 0 0 0 Ivanoff Bay 29 19 48 1 1 2 0 0 0 King Cove 145 138 283 14 17 31 0 0 0 Nelson Lagoon 25 18 43 2 2 4 0 0 0 Pavlof Harbor 22 17 39 1 0 1 0 0 0 Perryville $1 43 94 2 2 4 0 0 0 Sand Point 187 173 360 48 44 2 0 0 0 Squaw Harbor 46 19 65 9 4 13 0 0 0 Unspecified Places 52 25 7 36 5 41 2 0 2 Subtotal 923 663 1586 293 136 429 12 0 12 Kodiak Island Akhiok 61 54 115 1 1 2 0 0 0 Kaguyak 39 20 59 19 7 26 0 0 0 Karluk 58 40 98 2 1 3 0 0 0 Kodiak 2055 1743 3798 1668 1426 3094 27 17 44 Larsen Bay 48 61 109 9 9 18 0 0 0 Old Harbor 157 133 290 10 1l 21 0 0 0 Quzinkie 99 61 160 11 6 17 0 0 0 Port Lions 128 99 227 26 17 43 0 0 0 Woody Island 19 22 41 12 15 27 3 3 6 Kodiak Station 1897 1155 3052 1736 1034 2770 65 40 105 Unspecified Places 804 656 1460 668 526 1194 2 0 2 Subtotal 5365 4044 9409 4162 3053 7215 97 60 157 WESTERN GULF-TOTAL 6288 4707 10995 4455 3189 7644 109 60 169 Source: U.S. Bureau of the Census, 1970 Census, special computer runs. 61P Table 49 (continued) POPULATION BY RACE AND SEX--BY COMMUNITY WESTERN GULF OF ALASKA 1970 INDIAN ALEUT ESKIMO OTHER PLACE M F Tot M F Tot M F Total M F Total Alaska Peninsula Belkofski 0 0 ) 28 25 53 0 0 0 0 0 0 Chingnik 0 0 0 37 29 66 0 1 1 0 0 0 Chignik Lake 1 0 1 60 51 111 0 3 3 0 0 0 Cold Bay 3 2 5 9 7 16 2 3 5 4 3 7 False Pass 0 1 1 30 25 55 2 0 2 0 0 0 Ivanoff Bay 0 0 0 28 18 46 0 0 0 0 0 0 King Cove 2 1 3 128 120 248 1 0 1 0 0 0 Nelson Lagoon 0 0 0 23 16 39 ) 0 0 0 0 0 Pavlof Harbor 6 5 ll 14 12 26 1 0 1 0 0 ) Perryville 3 3 6 46 38 84 0. 0 0 0 0 0 Sand Point 4 4 8 128 121 249 2 1 3 5 3 8 Squaw Harbor ) 0 ) 15 14 29 0 0 0 22 1 23 Unspecified Places 0 0 0 17 17 34 0 0 0 0 0 0 Subtotal 19 16 35 563 493 1056 8 8 16 31 7 38 Kodiak Island Akhiok 0 0 0 60 53 113 0 0 0 ft) 0 0 Kaguyak 0 0 0 17 13 30 0 0 0 3 0 3 Karluk 0 0 0 56 39 95 0 0 0 0 0 0 Kodiak 32 21 53 244 235 479 14 17 31 70 27. 97 Larsen Bay 0 0 0 39 52 91 0 0 0 0 0 0 Old Harbor 1 0 1 142 #119 261 4 3 7 0 ) 0 Quzinkie 5 1 6 83 54 137 0 0 0 0 0 0 Port Lions 1 0 1 98 78 176 0 0 0 3 4 7 Woody Island 0 ) 0 0 0 0 0 0 0 4 4 8 Kodiak Station 4 7 ll 6 1 7 1 1 2 85 72 157 Unspecified Places 14 20 34 95 98 193 10 6 16 15 6 21 Subtotal 57 49 106 840 742 1582 29 °27 56 180 «113 293 WESTERN GULF TOTAL 76 865 141 1403 1235 2638 37 35 72 211 120 331 Source: U.S. Bureau of the Census, 1970 Census, special computer runs. A 421 major population centers. Air transportation provides the only scheduled passenger service from Sand Point to other Alaska communities. To supplement the limited scheduled service, there is a good deal of non- scheduled air traffic between Sand Point and communities on the Peninsula and Kodiak. Marine transportation is also important to the community. Much of the local transportation is provided by fishing vessels. In addition, Seattle-based steamships transport goods to Sand Point and return to the States with processed seafoods. King Cove The village of King Cove was established in 1911 following the construction of a large salmon cannery at the site (Alaska State Housing Authority 1968). Native families soon settled near the new plant and began taking part in the commercial fishing industry. The first U. S. Census enumeration of the village in 1939 recorded a population of 135. King Cove grew steadily until 1960 (U.S. Bureau of the Census 1960) and then held nearly constant between 1960 and 1970. Today the King Cove seafood processing plant is a large and well- developed installation processing salmon and crab. It is the only processing plant in the village, but has offered stable employment to local residents since it began operations in 1912. The average monthly employment for 1968 was 220. Additional workers must be imported from other parts of Alaska during peak periods. Employment has seasonal variations due to the nature of the fishing industry, but the plant's ability to process both salmon and crab keeps it in operation nearly year-round. King Cove is a major trading and supply center on the Alaska Peninsula. When the fishing vessels in the area need repair, the marina at the processing plant services them. In addition, the company's oil dock supplies fishing boats from communities within a 160 km. radium of King Cove. Commercial development in the village is primarily family- owned mercantile businesses, but these stores carry a wide variety of merchandise considering the remoteness of the community from sources of supply. Air freight shipments from Anchorage are generally routed through the large airport at Cold Bay and are then brought to King Cove, usually by amphibious aircraft. Air passenger flights via Cold Bay are available from King Cove to Anchorage three times each week. Steamships from Seattle serve the ice-free port of King Cove year-round. Cold Bay Cold Bay is the only predominantly white community in the Alaska Peninsula portion of the Western Gulf. The community was established as a military base and airport during World War II. Today the airport is jointly maintained by the Federal Aviation Agency and the State of 422 Alaska. The airport is used primarily as a refueling stop for inter- national freight shipping and much of the traffic is military cargo flights. Flying Tiger freight lines and Reeve Aleutian Airways maintain small base camps and a few employees in Cold Bay. The economy of Cold Bay consists almost entirely of state and federal government employment. The U. S. Fish and Wildlife Service headquarters for the management of the Izembeck and Aleutian National Wildlife Refuges are located in Cold Bay. The Alaska Department of Fish and Game also maintains a headquarters there. The U. S. Weather Bureau - has a station at the airport. There is a remote duty Air Force site 16 km. from town which is manned by 40 military personnel. State and federal housing is available so that government employees can move their families to Cold Bay. However, there are few accommodations for dependents of airline employees or military personnel. The Native population generally consists of just a few families and fluctuates from year to year. There is no cannery in Cold Bay, but the Natives do have some opportunities for employment with government agencies and airlines. Despite its remoteness, Cold Bay is served by non-stop passenger service from Anchorage six times per week. Depending on the type of aircraft, the flight takes between one hour and 45 minutes and two hours and 40 minutes. Cold Bay's large, modern airport serves as the trans- portation hub for the Alaska Peninsula area of the Western Gulf. Other Villages in the Western Gulf Region According to the 1970 Census, there are 12 other small villages in the Western Gulf region: Belkofski, Cape Sarichef Air Force Station, Chignik, Chignik Lake, Chignik Lagoon, False Pass, Ivanof Bay, Nelson Lagoon, Pavlof Harbor, Perryville, Port Moller, and Squaw Harbor. Nelson Lagoon is on the north coast of the Alaska Peninsula, False Pass is on Unimak Island, and the remaining villages are on the south side of the Alaska Peninsula. In 1970, the total population in these villages was 687. The population is made up almost entirely of Natives, with Aleuts comprising nearly 80 percent of the total. Only 92 whites reside in these villages and most are school teachers and their families, except for 26 military personnel at Cape Sarichef.1! Commercial fishing and fish processing offer the only significant sources of wage employment in any of the nine villages. In fact, several of the villages are essentially "company towns" associated with the local cannery. In the extreme case of Squaw Harbor, the cannery owns almost all the level land as well as the houses in the villages (Jones 1973). / lnorothy Jones, Sociologist, Institute of Social, Economic and Government Research, University of Alaska, Fairbanks. October 1973. Personal communication. 423 During the past several decades, there have been substantial, and sometimes quite rapid, changes in the population of these villages as families have migrated from one village to another or to larger cities. Some of these shifts have been only temporary, perhaps in response to seasonal demands of the fishing industry. Individuals may spend part of the year away from their homes working in canneries, in other local communities, or on Kodiak Island. ! Other shifts are more permanent. For example, some of the young people who leave the area to go to high school do not return. In addition, families choose to leave those villages that lack adequate employment opportunities in order to relocate in nearby villages with better job opportunities and superior community services (Jones 1973). As a result of this continuing process of migration, the population figures for these small villages have to be interpreted very cautiously. Existing villages may decline or even disappear while other villages grow and new villages are created. For example, the last remaining family recently moved from Pavlof (or Pauloff) Harbor, a village with a reported population of 39 in the 1970 Census (Jones 1973). Conversely, the village of Ivanof Bay came into existence between the 1960 and 1970 Census. Beginning in 1965, some of the residents of Perryville moved to nearby Ivanof Bay, which they felt was a better site for a village (U. S. Public Health Service 1969). Clearly, in examining the socioeconomic structure of the region, it is important to recognize the dynamic interactions among the small villages and between the villages and the larger communities. POPULATION AND EDUCATION Patterns of Population Change Figure 163 illutrates that over time there have been two massive shifts in population levels in the study region. Both shifts were due to outside forces imposed on the region. The first Russian contacts and occupation came around 1760 and from that time to the first U. S. census in 1880, the Native population dropped from 7,500 to 2,500 (Rogers 1972). After this tragic decline, the population remained virtually constant up to 1939. Then, during World War II, the large amount of military construction and the inflow of troops to the region caused the population to exceed 7,000 by 1950. In the postwar period, population continued to grow steadily; there was an increase of 15 percent between 1950 and 1960 and over 30 percent between 1960 and 1970 (Table 50). The gain in the most recent period occurred despite a decline in military personnel in the area. Although there has been strong growth overall, it has not been distributed evenly lMarion Soule, Kodiak Manpower Center, October 1973. Personal communication. 2tpid. 1,000 ; , ; — lopook TOTAL WESTERN GULF —-—-—— KODIAK ISLAND —-+— ALASKA PENINSULA 9,000+ 8,000 7,000} 6,000 500+ 4,000 3000+ 2,000 1,000}- ~ acon Fe ee ee ee | “se as s +s ae = —a =. jt 1 _| OF © ® w me =8 =f 48 = =3 = ss 8 82 ge S& gf 82 ge 88 & Figure 163. Regional population of the Western Gulf of Alaska, 1740-1970 (from Rogers 1972). 425 Table 50 POPULATIONS OF CITIES AND VILLAGES WESTERN GULF OF ALASKA 1929-1970 April 1 April 1 Aprill Oct. 1 Oct.1 %Change %Change 1970 1960 1950 1939 1929 1950-60 1960-70 WESTERN GULF REGION 10,995 8,653 7,510 3,235 2,844 415.2 +27.5 KODIAK ISLAND 9,409 7,174 6,264 2,094 1,729 +14.5 +31.2 Akhiok 115 84 72 - - +16.7 +36.9 Kaguyak 59 36 - - - - +63.9 Karluk 98 129 144 189 192 -10.4 -24.0 Kodiak (City) 3,798 2,628 1,710 864 442 +53.7 +44.5 Kodiak Station 3,052 2,743 3,000 - - - 8.6 +11.3 Larsen Bay 109 72 53 38 - +35.8 +51.4 Old Harbor 290 193 121 109 84 +59.5 +50.3 Ouzinkie (formerly Uzinkie) 160 214 177 253 168 +20.9 +25.2 Port Lions (formerly Afognak) 227 190 158 197 298 +20.3 +19.5 Woody Island 41 78 111 54 116 -29.7 -47.4 Unspecified Places 1,460 807 718 390 429 - - ALEUTIAN COMMUNITIES IN WESTERN GULF 1,586 1,479 1,246 1,141 1,115 +18.7 + 9.9 Belkofski 59 57 119 140 123) -52.1 + 3.5 Cape Sarichef A.F.S. 26 - - - - - - Chignik 83 99 253 224 - +24.1 -28.2 Chignik Lagoon 45 108 - os - - - Chignik Lake 117 107 - - - - - Cold Bay 256 86* - - - - * False Pass 62 41 42 - 7 -2.4 +51.2 Ikatan - - 29 - - - - Ivanof Bay 48 - - - - - - King Cove 283 290 162 135 - +79.0 - 2.4 Nelson Lagoon 43 - - - - - - Pavlof Harbor 39 77 68 61 52 +13.2 -49.4 Perryville 94 111 - - - - -15.3 Port Moller 6 7 33 45 =. - - Sand Point 360 254 107 99 69 - +41.7 Squaw Harbor 65 - 45 - - - - Unga - - 107 152 150 - - Unspecified Places - 249 281 285 721 - - * In 1960 the pppulation of the Air Force station at Cold Bay was not included in the population total. Sources: U.S. Bureau of the Census 1950, 1960, 1970b; Rogers 1972. 426 throughout the region. As shown in Table 50, some communities remained stagnant or declined during the 1960s while others grew very rapidly. The city of Kodiak also grew much more rapidly than the region as a whole. The wide range in regional growth rates resulted from the social and demographic diversity of the region's population. For example, Aleut birthrates are much higher than those for whites. Thus, the expected rate of natural increase for Native villages is higher than for a predominantly white community. The growth pattern is not only influenced by movements of families from one community to another, but also by the substantial migration into and out of the region as a whole. Finally, the movements of military personnel and the relative importance of defense related activities can be key factors in determining a community's growth or decline. Population on Kodiak Island The population of Kodiak Island can be divided into two distinct components: (1) the Kodiak urban area, consisting of the city of Kodiak, Woody Island, the Naval Base at Kodiak Station and the outlying areas around the city; (2) the villages located along the coast of Kodiak Island. The two components do, of course, have close social and economic ties but their demographic characteristics are very dissimilar. Most noticeably, the population of the Kodiak urban area is predominantly white, while 85 percent of the village population is Aleut (Table 49). The population of the Naval Base (Kodiak station, which became Kodiak Coast Guard Base in 1972) includes both military personnel and their dependents and is a little more than 90 percent white. Although . there is no regional data on the racial composition of military personnel, the proportion of whites to other racial groups in the Armed Forces is also 90 percent for the state of Alaska. Thus, Kodiak Station offers a typical example of how the inclusion of a military base can significantly alter the reported racial composition of a city or region. Except for people living on the Naval Base, three-fourths of Kodiak Island's population live in the city of Kodiak. Although the population of Kodiak is 80 percent white, more than one-third of the Natives on Kodiak Island live in Kodiak. In fact, more than 20 percent of the Natives in the entire Western Gulf region live in Kodiak. As the commercial and industrial center of the region, the city of Kodiak has historically offered economic opportunities that attract migration. As a result, Kodiak's rate of growth and the composition of its population is determined much more by migration than by natural increase. During the decade from 1960 to 1970, the Kodiak Census Division grew by 3l percent (Table 51). The civilian population grew by 2,500 or 48 percent while the number of military personnel was cut from 1,800 to 1,500. The white population grew by the relatively small amount of 24 percent; undoubtedly a reflection of the high proportion of whites in 427 Table 51 POPULATION GROWTII, 1960-1970 KODIAK CENSUS DIVISION % Change 1960 CENSUS 1970 CENSUS Of Total Male Fenale Total Male Female Total 1960-1970 Total Population 4,378 2,796 7,174 5,365 4,044 9,409 +31.2 Civilian 2,571 2,796 5,367 3,899 4,019 7,918 +47.5 Military 1,807 -- 1,807 1,466 25 1,491 -17.5 Personnel White 3,611 2,211 5,822 4,162 3,053 7,215 +23.9 Non-white 767 585 1,352 1,203 991 2,194 +62.3 Negro 72 46 118 97 60 157 #331 Indian 12 7 19 57 49 106 Aleut * . ® 840 742 1,582 +66.1 Eskimo ® * * 29 27 56 ) Other 683 532 1,215 180 §=113 293 / *In 1960 Census Aleut and Eskimo are included in the "other" category. Sources: U.S. Bureau of the Census 1960, 1970b; Babb 1972. 428 the military. Since 1970 the military cutback has continued; the number of personnel was reduced to 1,300 in 1971 and to 660 in 1972: (Alaska Department of Labor 1972). In July 1972 the base was transferred to the Coast Guard which now has 600 personnel stationed there. Direct measures are not yet available but it is certain that the direct and indirect effects of this drastic military cutback will have a significant impact upon Kodiak's population. The nonwhite population in the Kodiak Census Division grew by more than 60 percent between 1960 and 1970, an average annual increase of 5 percent. That growth is clearly in excess of the rate of natural increase due to significant migration into the Kodiak area. The figures in Table 52, although only approximations, provide estimates of natural increase and migration as the sources of population growth. The estimated net increase in civilian nonwhite population is 874 persons. Of that total, 250 persons or 28 percent, are attributable to net in-migration. The remaining population growth of 625 persons is natural increase (births minus deaths) of the resident nonwhite population. Despite the reduction in military personnel, there is an estimated in-migration of 332 white persons. Since some military personnel are accompanied by their dependents, a reduction in the military personnel generate a reduction in the civilian population as well. Thus, if one could adjust for all military related population movements, the net in- migration of non-military families would be even larger than the estimates in Table 52. Even without making this adjustment, migration accounts for 20 to 30 percent of the population growth among whites as well as nonwhites. Table 53 shows how the population growth was distributed among the city of Kodiak, Kodiak Station, and Kodiak Island villages and outlying areas. Although only 40 percent of the white population lived in the city of Kodiak, over 60 percent of the growth in the white population was in the city. It is interesting that the population of Kodiak Station increased even though the number of military personnel was reduced. This was due to the substantial increase in the housing provided on the military base for families of military personnel. The Native population throughout the Kodiak area grew quite rapidly. In both the city and the villages and outlying areas the growth was in excess of the rate of natural increase. Thus, there seems to have been a general pattern of migration of Natives from other areas to Kodiak Island. Table 52 also contains estimates of the rates of natural increase for 1960, 1970, and average rates over the decade. For all population groups shown, there is an extremely sharp drop in the rate of natural increase between 1960 and 1970. This is due to the reduction in the birthrate during that period (Rogers 1971). This phenomenon occurred throughout the country and is generally attributed to several factors. lu.z. Parker, Public Information Officer, Kodiak Coast Guard Base, October 1973. Personal communication. Table 52 COMPONENTS OF POPULATION CHANGE 1960-1970 KODIAK CENSUS DIVISION All_Races White Non-white Change Change Change 1960 1970 1960-70 1960 1970 1960-70 . 1960 1970 1960-70 Population 7174 9409 2255 5822 7215 1393 1352 2194 842 Military personnel : 1807 1491 -316 1626 1342 -284 181 149 -32 Civilian population $567 7918 2551 4196 5873 1677 1171 2045 874 Births 248 259 2457 172 175 1646 76 84 811 Deaths 39 56 487 24 34 301 15 22 186 Natural increase 209 203 1970 148 141 1345 61 62 625 Rate of natural increase (total pop.) {2.91% 2.16 2.377 2.54 1.95 2.067 4.51 2.82 3.53 3 Rate of natural increase (civ. pop.) 3.893 2.56 2.973 3.53 2.40 2.67 5.21 3.03. 3.89 Migration 265 48 217 Civilian Migration 581 332 249 Icalculated assuning that 90 percent of military personnel are white. That is the average proportion for the state during the 1960-1970 period. 2 ° : <2 . “Calculated using the average of the 1960 and 1970 population figures. “Calculated using the average of the 1960 and 1970 civilian population fisures. Sources: U.S. Bureau of the Census 1960, 1970b. 6¢P Table 53 POPULATION CHANGE 1960-1970 Kodiak, Kodiak Station and Kodiak Island Village and Outlying Areas (Number of Persons) TOTAL WHITE NONWHITE 1960 1970 Change 1960-70 1960 1970 Change 1960-70 1960 1970 Change 1960-70 City of Kodiak 2,628 3,798 +1,170 2,222 3,094 +872 406 704 +298 Kodiak Station 2,745 3,052 +309 2,469 2,770 +301 274% 282 +8 Kodiak Island Villages and Outlying Areas 1,803 2,559 +756 1,131 1,351 +220 672 1, 208 +536 *Estimated by assuming that 10 percent of population is nonwhite. Sources: U.S. Bureau of the Census 1960, 1970b; Rogers 1972. Osp 431 There were improvements in birth control methods and programs to provide information on family planning. In the Kodiak region, the change in the Native birthrate was remarkable. The rate of natural increase fell from 5 percent in 1960 to 3 percent in 1970. The rate of natural increase among whites also declined and it remained lower than the rate for nonwhites, but the gap between the two groups was narrowed. In 1970 the rate of natural increase for nonwhites was about 25 percent higher than the rate for whites. Further evidence confirming the drop in birthrates is provided by the fertility ratios in Table 54. A fertility ratio is the number of children under five years old per 1,000 women of childbearing age, which is taken to be all women between 15 and 49 years old (Rogers and Cooley 1963). By including data for Alaska and for the U.S., Table 54 shows that the decline in the birthrate was widespread. The fertility ratio for nonwhites in Kodiak is only 13 percent higher than the fertility ratio for whites. That difference is even smaller than the one measured by the rates of natural increase in Table 52. However, the fertility ratios for Kodiak are very high when compared either to the Alaska or U.S. average. Despite the absolute reduction in the birthrate, the natural growth rate for Kodiak remains high when compared to other regions. Population in Alaska Peninsula Communities A precise description of population change in the Alaska Peninsula communities is difficult to obtain because of the’ form in which census data are reported. The more detailed census information, particularly in 1960, is reported on the basis of census divisions. Data for the Aleutian Island Census Division are reported in Table 55 because the communities in the Western Gulf study region are included within this division. As shown in that table, total population in the Aleutian Islands Census Division grew by 34 percent from 1960 to 1970, a pace very similar to that observed in the Kodiak region. But in the Aleutian Islands, over half of the growth is due to the expansion in military personnel from 2,400 to almost 3,700. As a result, the white population grew very rapidly, more than 50 percent. In sharp contrast, the size of the Native population remained essentially constant over the decade. The composition of the population in Alaska Peninsula communities differs markedly from the Aleutian Islands Census Division taken as a whole (Table 56). More than two-thirds of the population on the Alaska Peninsula is Aleut while the population of the Aleutian Islands is predominantly white. The Alaska Peninsula has more than half of the Aleut population in the census division and only eight percent of the white population because the major military installations are located in the western part of the region. The number of military personnel on the Alaska Peninsula is negligible. Clearly the aggregate statistics for the census division cannot accurately describe the situation in the Alaska Peninsula communities. 1960 Children under 5 Women 15-49 Fertility ratio 1970 Children under 5 Women 15-49 Fertility ratio Table 54 FERTILITY RATIOS* BY RACE KODIAK CENSUS DIVISION 1960 and 1970 ALASKA ALASKA KODIAK ALASKA WHITE = NON-WIITE TOTAL 34,193 24,602 9,591 963 49,407 38,660 10,747 1,406 692 636 892 685 32,075 23,825 8,250 1,073 72,512 58,503 14,009 2,144 442 407 589 500 *Children under 5 years per 1,000 women 15-49 years old KODIAK 736 1,142 644 819 1,683 487 Sources: Rogers and Cooley 1963; U.S. Bureau of the Census 1960, 1970b. KODIAK NON-WHITE 227 264 860 254 461 551 TOTAL U. S. (in thousands) 20,321 41,601 488 17,119 48,624 352 cov Table 55 POPULATION GRONTiI, 1960-1970 ALEUTIAN ISLANDS CENSUS DIVISION % Change 1960 CENSUS 1970 CENSUS Of Total Male Female Total Male Female Total 1960-1970 Total Population 4,254 1,757 6,011 5,772 2,285 8,057 +34.0 Civilian 1,842 1,757 3,599 2,108 2,260 4,368 +21.4 Military 2,412 -- 2,412 3,664 25 3,689 +52.9 Personnel White 2,905 785 3,690 4,309 1,255 5,564 +50.8 Noriewhite 1,349 972 2,321 1,463 1,030 2,493 + 7.4 Negro 77 8 85 216 21 237 +178.8 Indian 13 8 21 36 25 61 Aleut * * * 1,054 918 1,972 + 0.9 Eskimo bl * * 16 14 30 Other 1,259 956 2,215 141 52 193 *In 1960 Census Aleut and Eskimo are included in the "other" category. Sources: U.S. Bureau of the Census 1960, 1970b; Babb 1972. Table 56 ALEUTIAN ISLANDS AND ALASKA PENINSULA POPULATION, 1970 Aleutian Islands Census Division Alaska Peninsula Communities Distribution Distribution of population of population Population (percent) Population (percent) Total population 8,057 100.0 1,509 100.0 White 5,564 69.1 388 25.7 Nonwhite 2,493 30.9 1,121 74.3 Aleut 1,972 24.5 1,022 67.7 Other $21 6.5 99 6.6 Sources: Babb 1972, U.S. Bureau of the Census, 1970 Census, special computer runs. 435 The data in Table 50 indicate that the total population of the Alaska Peninsula increased by 107 persons (9.9 percent) from 1960 to 1970. Sand Point was the only established community which exhibited significant increases, while most other villages lost a substantial portion of their population. Although direct information is not available to divide growth into natural increase and migration components, some approximate allocations can be made. If it is assumed that the birth and death rates are roughly the same as for the nonwhite population in Kodiak, the rate of natural increase would be 3.89 percent in the Aleutians (Table 57).1 This would imply a natural increase over the decade of about 600 persons and, thus, a net out-migration of nearly 500 persons from the Alaska Peninsula villages. The fertility ratios shown in Table 58 indicate that the use of the Kodiak rate of natural increase may substantially underestimate the natural growth in the Alaska Peninsula villages. Fertility ratios for nonwhites in the Aleutian Islands Census Division, and particularly in the Alaska Peninsula villages, are much higher than those in Kodiak. In fact, the 1970 Alaska Peninsula fertility ratio for nonwhites is nearly 50 percent higher than the comparable ratio for Kodiak. If, in light of this, the estimated rate of natural increase in the Alaska Peninsula villages were increased, the estimate of net out-migration would also increase. Summary During the period 1960 to 1970, total civilian population in the Western Gulf region has shown strong growth despite the reduction in military personnel stationed there. The civilian population movements due to migration, among both whites and nonwhites, have increased the importance of the city of Kodiak as the social and economic focal point for the Western Gulf reigon. School Facilities and Enrollments Elementary and High Schools Between 1960-61 and 1970-71 total school enrollment on Kodiak Island rose from 1,356 to 2,493 students, an increase of 84 percent for the decade (Table 59 and Figure 164). Between 1970-71 and fall 1973 total enrollment dropped by 12 percent to 2,187 students. Ifhe vital statistics for the Aleutian Islands Census Division are not used here because of questions concerning their reliability. They are, for example, grossly inconsistent with the fertility ratios reported in Table 56. It may be that lack of medical facilities in the region has caused underreporting in birth statistics. Table 57 POPULATION CHANGE 1960-1970 ALEUTIAN ISLANDS ALASKA PENINSULA Nonwhites All Races 1960 1970 Change 1960-70 1960 1970 Change 1960-70 Civilians 1,961 2,056 +95 1,479 1,586 +107 Natural Increase 781 596 Rate on Natural Increase 3.89 3.89 Migration -686 -489 Sources: U.S. Bureau of the Census 1960, 1970b; U.S. Bureau of the Census, 1970 Census, special computer runs. FERTILITY RATIOS* BY RACE Table 58 ALEUTIAN ISLANDS REGION 1960 and 1970 ALASKA ALEUTIAN ISLAND CENSUS DIVISION TOTAL WHITE NONWHITE TOTAL WHITE NONWHITE (in thousands) 1960 Children under 5 34,193 24,602 9,591 608 242 366 20,321 Women 15-49 49,407 38,660 _ -10,747 853 432 421 41,601 Fertility ratio 692 636 892 608 560 869 488 1970 Children under 5 32,075 23,825 8,250 738 430 308 17,119 Women 15-49 72,512 58,503 14,009 1,150 694 456 48 624 Fertility ratio 442 407 589 642 620 675 352 1970 Alaska Peninsula Commmities Children under 5 213 29 184 Women 15-49 299 74 225 Tertility Ratio 712 392 818 *Children under 5 years per 1,000 women 15-49 years old. Sources: Rogers and Cooley 1963; U.S. Bureau of the Census 1960, 1970b; U.S. Bureau of the Census, 1970 Census, special computer runs. Lop YEAR 1958-59 1959-60 1960-61 1961-62 1962-63 1963-64 1964-65 1965-66 1966-67 1967-68 1968-69 1969-70 1970-71 1971-72 1972-73 Fall 1973 Sources: Sullivan and Rose 1970, Alaska Department of Education 1973. Table 59 TOTAL SCHOOL ENROLLMENT. KODIAK ISLAND 1958-59 to 1972-73 ELEMENTARY* HIGH SCHOOL** 438 WHITE. NATIVE OTHER SUBTOTAL WHITE NATIVE OTHER SUBTOTAL TOTAL 960 817 814 NA 905 850 1016 1088 1279 1349 1207 1189 1228 1168 328 282 309 NA 362 342 342 343 387 406 509 568 570 553 *Grades K through 8 ** Grades 9 through 12 23 16 10 NA 39 23 28 37 46 60 72 76 63 53 1311 1115. 1133 NA 1306 1226 1386 1468 1712 1815 1788 1832 1861 1774 1797 1686 189 180 182 NA 240 249 313 345 358 384 403 383 412 361 31 32 41 NA 43 46 41 11 34 82 82 135 215 209 3 0 0 NA 2 12 223 212 223 NA 285 299 363 361 398 475 494 527 632 582 442 501 1534 1327 1356 NA 1591 1525 1749 1829 2110 2290 2282 2360 2493 2356 2239 2187 2500 T T — T T T T T T T Toss T T -— *. TOTAL ENROLLMENT -—--—- ». -—eame L . na 2250 oseeeeeee ELEMENTARY Yo — ————=== HIGH SCHOOL . | 2,000 1,750} on 4 ee 7 o 1,500F's ms 4 . . 1, Neer . a 1.2507", Seat 4 1000+ 4 750 4 7 ae 500}- ee | ~_o—---- —---~ 250, _ _ ~ 4 1 1 le 4 1 = 1 1 1 L L 1 L L © © © © o © © © © oO © oO ry © © z o a $ 8 S$ 5 8 SF F S$ 8B F 8 8 F TF BF 1 : = 8 8 ¢ 8 & & &@ 8 & 8 &@ J 2 B B Bg Figure 164. kodiak lane school enrollment, 1958-59 to 1972-~35 {from Sullivan and Rose 1970, Alaska Department of Education 1975). 440 In fall 1973 Kodiak's elementary school enrollment was 1,686 compared to 1,861 in the 1970-71 school year, a drop of 9 percent (Table 59). However, most of the decrease is accounted for by a drop in the enrollment at the Base elementary school following the cutback in military personnel (Alaska Department of Education 1970, 1973). The remainder of the decrease is attributable to a significant decline in the birthrate. High school enrollment has been somewhat erratic in recent years, but in general has declined since 1970 (Table 59). All of the schools on Kodiak Island, except St. Mary's School, are administered by the Kodiak Island Borough School District. The operating budget for 1972-73 was more than 4,270,000 dollars; 333,000 dollars of it came from local sources (Main, Lafrentz and Co. 1973). In the Kodiak urban area, the Borough operates three elementary schools (East, Main, and the Coast Guard Base), a junior high school, and the Kodiak-Aleutian Regional High School. In addition to these schools, about 13 percent of the borough students attend small schools in rural areas. Total enrollment for these predominantly Native schools in the fall of 1973 was 285 (Table 60). The elementary schools at Akhiok, Chiniak, Karluk, and Larsen Bay have two classrooms each, and Port Lions has three. A new 300,000 dollar elementary school was completed at Ouzinkie in 1973 (Kodiak Island Borough 1973). In the past, low school enrollments in the villages have not justified the establishment of high school programs. As a result, village students attend the regional high school in Kodiak. Beginning in 1972 the school at Old Harbor extended its program to offer a secondary curriculum. Ninth graders are now required to attend high school in Old Harbor, but students in the higher grades have the option of attending high school in Kodiak. The fall 1973 secondary school enrollment at Old Harbor was 15 students. School Facilities and Enrollments All of the villages on the Western Gulf portion of the Alaska Peninsula, except Squaw Harbor, have small elementary schools. All of the schools are run by the State Operated School System except for King Cove, which is an independent school district (Alaska State Housing Authority 1968). In fall 1973, the total enrollment for these schools was 396. This is an increase of more than 50 percent from the 1965-66 average of 259 students. During this interval the proportion of white enrollment dropped 20 percent. In fall 1973, the largest school was Sand Point with 133 students and 9 teachers. Ivanof Bay was the smallest with 12 students 1 teacher. Until very recently, there were no high schools on the Alaska Peninsula due to low population and scattered distribution of settle- ments. Students attended U. S. Bureau of Indian Affairs high schools in Alaska or other states; most went to high school in Anchorage or Kodiak and lived with local families under the State Boarding Home Program. In the past few years, a secondary curriculum has been added to the schools at King Cove and Sand Point. The school program in these two communities now continues through the twelfth grade. Table 60 SCHOOL ENROLLMENTS WESTERN GULF OF ALASKA ALASKA PENINSULA Belkofski Chignik Bay Chignik Lagoon Chignik Lake Cold Bay False Pass Ivanof Bay King Cove Nelson Lagoon Perryville Sand Point Squaw Harbor TOTAL Source: Students Fall 1973 15 19 8 32 26 8 12 113 11 19 133 Teachers 1 396 29 KODIAK ISLAND 44] Fall 1973 Kodiak Villages Students Teachers Akhiok 32 2 Kaguyak - - Karluk 16 1 Larsen Bay 20 1 Old Harbor 93 6 Ouzinkie 39 2 Port Lions 55 3 Chiniak School _30 2 SUBTOTAL 285 17 Kodiak Urban Area Kodiak Aleutian Regional High Sch. 501 Kodiak Jr. High Main Elementary Kodiak Base Elementary East Elementary SUBTOTAL 312 440 371 278 1,902 KODIAK TOTAL 2,187 Alaska Department of Education 1973. 44 20 22 19 19 124 141 442 To serve rural students from Kodiak, the Alaska Peninsula, and the Aleutian Islands, the Kodiak-Aleutian Regional High School was built by the State of Alaska in 1967. State operation of the facility ended after the 1972-73 school year and the Borough has since taken over the 22 classroom building for use as the borough high school. A four million dollar borough addition to this high school of 10 classrooms, swimming pool, gymnasium, and library-media center was scheduled to open in November 1973.! Along with the regional high school, the State operated a dormitory to house rural students. The dormitory also closed after the 1972-73 school year and future use of the building has not been determined. Since fall 1973 students from Kodiak Borough villages, who formerly lived in the dormitory, are being housed in a cottage-style living arrangement. The cottages were converted from living quarters formerly used by the faculty and staff of the state regional high school. Each cottage has a central apartment for the houseparents and adjoining apartments for girls on one side and boys on the other. About 12 students live in each cottage. The living arrangement is designed to offer greater personal care than was provided in the dormitory. In its first two months of operation, the program has been highly successful according to school administrators, students, and cottage houseparents. Formerly about one-third of the dormitory students dropped out during the first few weeks of school. Be comparison, only three students out of 55 who started in fall 1973 have gone back to villages.? About 30 students from Alaska Peninsula and Aleutian Island communities are attending Kodiak High School and living with local families under the State Boarding Home Program. High school personnel indicated this program is not as successful as the cottage style living arrangement, but at present, students residing outside the borough are not eligible to live in the cottages. Most Kodiak students follow an educational program of basic subjects such as English, math, science and social students through their freshman and sophomore years. During the last two years of high school, they can continue these courses at a more advanced level or obtaining vocational training. About one-third of the high school students choose the vocational programs is substantially higher. The head of the program estimated that about 75 percent of the Native males and 50 percent of the Native females choose the vocational curriculum. 4 lGordon Kent, Curriculum Director, Kodiak High School, October 1973. Personal communication. 2Jim Johnson, Cottage Supervisor, Kodiak Island Borough, October 1973. Personal communication. 3Nelda Osgood, Home School Coordinator, Kodiak High School, October 1973. Personal communication. 4Gordon Kent, Curriculum Director, Kodiak High School, October 1973. Personal communication. 443 All vocationl classes are open to males and females, but the business education and home economics courses attract most of the female students. Business education courses include office procedures, office machines, bookkeeping, typing, and shorthand. Most of the students enrolled in the technical and industrial courses are males. This portion of the vocational program has course offerings which include carpentry and boat building, small and outboard engines, fisheries, electronics, diesel mechanics, automotive mechanics, metal shop, welding, metal fabrication, machine shop trades, drafting, and surveying. The most frequent specialization among Native students is the fisheries program. Beginning in the 1973-74 school year, much of the program is being taught on board a new 12.6 m. Delta Marine seiner. The floating classroom is used in conjunction with such courses as fisheries, galley cooking, marine diesel, oceanography, electronics, and small engines. According to the director, the skill level attained by individuals varies, but all the vocational programs are geared to equip students with job-entry level skills. In addition to course work, many vocational students receive credit for on-the-job training in their specific interests through cooperative agreements with the school and local businesses. In the fall of 1973, about 60 students were receiving some co-op experience. The director said the programs attempt to train students in vocations which will give them the potential for long-term employment in the Kodiak Island area. Kodiak Community College A community college program began in Kodiak in 1968 as a joint venture of the University of Alaska and the local borough school district. In the past five years, the program has grown from its initial enrollment of 95 students to 600 students in the fall of 1973 (Kodiak Island Borough 1973). The credit division of the Kodiak Community College offers a two year program leading to an Associate of Arts Degree with majors in behavioral sciences, liberal arts, office administration, police administration, science, vocational arts, and fisheries technology. In fall 1973, there were 345 students enrolled in nine daytime and 33 evening credit courses. About 30 students were carrying a full-time academic load.1! The non-credit division of the Community College is sponsored locally. The fall 1973 program included 18 non-credit courses with an enrollment of 167 students in a wide range of courses including fur sewing, conversational Aleut, clerical skills, cake decorating, and welding. In addition, about 80 students are enrolled in an adult basic education program which is designed to prepare students to take the GED test series to attain a State of Alaska high school equivalency diploma. This program is offered in the city of Kodiak and in five of the island's outlying villages. ‘carolyn Floyd, Director, Kodiak Community College, October 1973. Personal communication. 444 The first building of the Kodiak Community College was completed in October 1972 under the University of Alaska construction program. The new facility includes seven classrooms, library, office, and student lounge; however, space and equipment are still inadequate to handle all of the College's programs. In October 1973 ground was broken for a vocational building which will house two classrooms, an arts and crafts room, fisheries and marine diesel shops, maintenance shop, and additional office space. It is scheduled for completion in 1974. Educational Attainment A standard measure of a population's general education level is the median school years completed by persons more than 25 years old. Asa whole, Alaska has historically had a relatively high educational level (Rogers and Cooley 1963). This remained true in 1970 as the median school years completed by both males and females were higher in Alaska than in the total United States (Table 61). In the Kodiak Island Borough and Aleutian Islands Census Divisions, the median school years for men were lower than the state average but still exceeded the U. S. average. The same was true for women in Kodiak, but in the Aleutian Islands, the median school years for women were substantially lower than either the state or U. S. average. Another measure of educational attainment is the percentage of high school graduates in the more than 25 years of age population. Kodiak's figures of 57.2 percent for males and 56.5 percent for females are below state averages, but considerably higher than the national percentages of 51.9 for males and 52.8 for females. In the Aleutians, 65.5 percent of the men completed high school, a proportion nearly up to the statewide average. However, only 48 percent of the women in the Aleutian Islands completed high school, which is a lower fraction than the national or state average. As shown in Table 61 these high levels of educational attainment are only characteristic of the white population. In the Kodiak Island Borough only 18.9 percent of the more than 25 year of age nonwhite population were high school graduates compared to 71.5 percent for whites. Similarly, in the Aleutian Islands only 20.5 percent of the nonwhites were high school graduates compared to 79.2 percent for whites. At the other end of the scale, Alaska also tends to have a relatively large proportion of persons more than 25 years of age who have no education at all. However, in Kodiak and the Aleutians less than two percent of this group has had no education, a figure on a par with the U. S. average. A breakdown of these statistics by race reveals that less than one percent of whites had no education, while more than five percent of nonwhites had no education. These figures, although high, are lower than statwide where 12 percent of the more than 25 years of age nonwhites had no education. Years Of School Completed KODIAK ISLAND BOROUGH Nomhice i Number Percent, KODIAK STATION ‘6 1d and_over Wo school yeare coapleced Elenentaryt High School: Median School Years Completed 25 years old and ov Wo school years cospleced Elementary: Migh School: ‘AL, 25 yeare old ard over ‘Ko school years coup leted Elementary: High Schools High School Graduats # Total for Kodiak Census Division Bureau of the Census, 1970 Census, special computer rune Total White Number Percent Number Perc: 2,721 1,251 7 6 68 7 36 10 97 “0 190 6 29% 1 607 ‘ 195 x 96 86 a2.3e ma i230 2 aL 0 0. a3 you 343 a 0. 3948 moo 202 16.4 106 120 167 13.6 4312. 418 34.0 356 40. 1310.8 a3 15. 836.7 839. 4 5.0 9 6 56.3 n. 12.38 mM 2,951 2,133 30.7 6 1093.7 20 1073.6 a ase 5.3 51 392 13.3 202 458 15.5 312 4,025 34.7 896 328 La 309 9 6.1 a6 uy 5.0 us 369 ‘470 1 a 4a 37 94 92 a ww 105 146 129 Boootiti ben aeuaeovaoas 0 0, 0. 1 2 7 8 2 0. Table 61 EDUCATIONAL ATTAINGENT HODIAK, ALEUTIAN ISLANDS, ALASKA, AMD U.S, 1970 ‘ALEUTIAN ISLANDS, Total White Nonwhite Mumber Percent Mumber Percent Number Percent Mumber Percent Kusber Percent Muaber Percent Percent aid 1,616 395 21g ° 42 2 1.8 1004.5, 7 3 a5 a0 49671 26 10 2.9 1.9 7 26 6 3h 25 6.7 42s, 3S 46 50 16 10.0 2212, as 133 7 14.7 3.6 836 37.8 142 48.9 96 36.1 19.0 301 13.6 262 16.2 9 146 65. wo 81 167 10.3, b 1.8 20 1326.0 Me 1.2 16 ng Le 5.5 a6 66.2 28.9 124 ™ ™ 908, 300 408 Dole 0 3 2.6 6 o 0 6 a3 no iz. ° uo 3.2 36 6.2 5 31 20 3 8.0 6 o 65 159 17.5, 9 60 15.2 26 30.4 250 6 39.6 79 8.7. 69 10 isa se 54 0 8.0 m2. v 7 4 a. o 1.6 mA. mA. 3,119 2,116 003, 55 ° 33 2 a2. 164 7 157 3 16. 266 26 20 3, 12 3 u 202 2 6 198 a1 uy 1 1. “an oe 47 1, aa ayuz 992 120 a7, a, 380 331 “9 as. 6 2 a Bb 7 2, 156 133 a 6, 1 66. 26. * Spr 446 LABOR FORCE AND EMPLOYMENT Labor Force The size of the labor force in any region is determined jointly by the characteristics of the local population and by the availability of employment opportunities. Obviously, in the long-run there has to be a close relationship between the size of the population base and the size of the labor force. However, this relationship is not necessarily constant over time, nor is it the same for all regions. In particular, there can be large differences in the observed participation rates, for example, in the proportions of the populations that choose to seek employment. One of the key factors determining the participation rate is the availability of employment opportunities. When jobs are easy to find, more people decide to seek employment, thus causing an increase in the participation rate and in the labor force. In the Western Gulf region, both the size of the local population and the employment opportunities are subject to large fluctuations due to outside forces. First, the movement of military personnel and dependents can cause sharp changes in the regional population. In addition, the major private industry is fishing and fish processing which exhibits wide variation seasonally and from one year to another due to weather conditions and cycles in the fish populations. Consequently, while the workforce in the Western Gulf is trending upward, it displays considerable variation around the long-run growth trend (Table 62). In Kodiak, the average civilian work force in 1971-72 is 50 percent larger than the average work force in 1961-62. For that same period, the civilian work force increased by 58 percent in the Aleutian Islands Census Division, but the Western Gulf region includes only part of the Aleutian Islands Census Division. In terms of pop- ulation, the Western Gulf includes about one-third of the census division. Thus, the statistics reported for the Aleutian Islands Census Division can only be regarded as rough indicators of the characteristics of the communities on the Alaska Peninsula which are included in the Western Gulf region. The data in Table 63 show how the participation and unemployment rates in the Western Gulf region compared to the state averages. Participation rates in the Aleutian Islands were extremely low for both men and women. The male participation rate in the Aleutians was 68 percent, compared to 79 percent for the state and for Kodiak Island Borough; the female participation rate was only 30 percent, compared to 46 percent for the state and 55 percent for Kodiak. There are major differences in the participation rates of whites and Natives. In both the Aleutian Islands and Kodiak the participation rate for white males was roughly 87 percent compared to less than 60 percent for Native males. However, the participation rates for Native males in this region were higher than the statewide rate of 51 percent for Native males. 447 Table 62 WORKFORCE ESTIMATES Kodiak Aleutian Islands Census Division Census Division 1961 2364 1551 1962 2315 1469 1963 2439 1624 1964 2483 1854 1965 2986 1837 1966 3447 1817 1967 3666 2024 1968 3418 2137 1969 3090 2015 1970 3155 1987 1971 3332 2489 1972 3689 2284 Source: Alaska Department of Labor, various dates. Table 63 LABOR FORCE AND EMPLOYMENT 1970 Kodiak, Aleutian Islands, Alaska and U.S. Kodiak Island Borough Aleutian Islands Alaska U.S. Total White Nonwhite Total White Nonwhite Total White Nonwhite TOTAL CIVILIAN POPULATION, 16 years old and over 3,813 2,722 1,091 2,317 1,079 1,238 159,702 128,367 31,335 139,089,535 Civilian labor force 2,585 2,013 572 1,088 571 517 98,296 84,960 13,336 80,051, 046 Percent of total (participation rate) 67.8 74.0 52.4 47.0 52.9 41.8 61.5 66.2 42.6 57.6 Employed 2,342 1,863 479 925 547 378 89,236 78,231 11,005 76,553,599 Unemployed 243 150 93 163 24 139 9,060 6,729 2,331 3,497,447 Percent of civilian labor force 9.4 7.5 16.3 15.0 4.2 26.9 9.2 7.9 17.5 4.4 MALE, 16 years old and over 2,062 1,457 605 1,042 392 650 76,547 61,363 15,184 65,282,635 Civilian labor force 1,624 1,263 361 709 344 365 60,293 52,490 7,803 49,549,239 . Percent of total (participation rate) 78.8 86.7 59.7 68.0 87.8 56.2 78.8 85.5 51.4 75.9 Employed 1,480 1,191 289 609 334 275 54,114 47,931 6,183 47,623,754 Unemployed 144 72 72 100 10 90 6,179 4,559 1,620 1,925,485 Percent of civilian labor force 8.9 5.7 19.9 14.1 2.9 24.7 10.2 8.7 20.8 3.9 FEMALE, 16 years old and over 1,751 1,265 486 1,275 687 588 83,155 67,004 16,151 73,806,900 Civilian labor force 961 750 211 379 227 152 38,003 32,470 5,533 30,501,807 Percent of total (participation rate) 54.9 59.3 43.4 29.7 33.0 25.9 45.7 48.5 34.3 41.3 Employed 862 672 190 316 213 103 35,122 30,300 4,822 28,929,845 Unemployed 99 78 21 63 14 49 2,881 2,170 711 1,571,962 Percent of civilian labor force 10.3 10.4 10.0 16.6 6.2 32.2 7.6 6.7 12.9 5.2 Sources: U.S. Bureau of the Census, 1970 Census, Alaska special computer runs; U.S. Bureau of the Census 1970b. Shp 449 Along with the low participation rates, the unemployment rate for Natives was 16 percent in Kodiak and 27 percent in the Aleutians. By comparison, the white unemployment rate was 7.5 percent in Kodiak and 4.2 percent in the Aleutians. The high nonwhite rate accompanied by a low participation rate is precisely what would be expected. The lack of employment opportunities has caused Natives to drop out of the labor force. Furthermore, this picture is consistent with the migration patterns discussed previously. The lack of employment opportunities contributes to the observed out-migration from the Aleutian Island region. Although Kodiak's Native unemployment is high compared to the white rate, Kodiak's rate is lower than the average statewide unemployment rate for nonwhites. Due to seasonal factors, the unemployment rates are probably overestimated and the participation rates are underestimated by the data in Table 63. The 1970 census was taken on April first, and that is close to the seasonal low point for employment in the Western Gulf region. The comparison of the different rates at that point in time would, however, still produce relevant results. Occupations of the Employed The government sector has traditionally been one of the most important in Alaska's economy, and in 1970 the government hired a third of the male work force and 41 percent of the female work force (Table 64). In the Aleutian Islands the share of government employment, 41 percent for males and 60 percent for females, represented an even larger portion of the workers than the state average. By Alaska standards the Kodiak Island Borough had a low proportion of government employment (30 percent), and of that, more than half was local government employment. In contrast, government employment in the Aleutians consists almost entirely of state and federal employees. Since Kodiak functions as the commercial and industrial center of the Western Gulf region, the private sector accounts for a relatively large proportion of Kodiak's total employment. The addendum to Table 64 again emphasizes the importance of the military on both the Kodiak area and the Aleutian Islands. The distribution of occupations in the Western Gulf region is shown in Table 65. Perhaps the major deviation from the state pattern is the relatively large number of individuals (particularly females) employed as operatives and laborers. This reflects the large amount of employment generated by the fish processing industry in the Kodiak area. Among the female workers in Kodiak, a large number have apparently found employment as cannery workers rather than as clerks and secretaries. Seasonal Variation in Employment In tracing the movements over time, the pattern of employment in the Western Gulf of Alaska is dominated by the pronounced seasonal fluctuations in the fishing industry. Figures 165 and 166 show the Table 64 Class of Worker Kodiak 1970 KODIAK ISLAND BOROUGH KODIAK STATION TOTAL WHITE NONWHITE TOTAL CLASS OF WORKER Number Percent Number Percent Number Percent Number Percent (Civilians) MALES, Employed, 16 years old and over 1,480 1,191 _ 289 84 Employee of Private Company 960 64.9 740 62.1 220 76.1 18 21.4 Employee of Own Corporation 30 2.0 30 2.5 0 0.0 0 0.0 Federal Government Worker 116 7.8 105 8.8 ll 3.8 66 78.6 State Government Worker 76 5.1 52 4.4 24 8.3 0 0.0 Local Government Worker 189 12.8 161 13.5 28 9.7 0 0.0 Self-Employed Worker 109 7.4 103 8.6 6 2.1 0 0.0 Unpaid Family Worker 0 0.0 0 0.0 0 0.0 0 0.0 FEMALES, Employed, 16 years old and over 862 672 190 227 Employee of Priv. Co. 505 58.6 379 56.4 126 66.3 108 47.6 Empl. of own Corp. 0 0.0 0 0.0 0 0.0 0 0.0 Fed. Gov. Empl. 65 7.5 4l 6.1 24 12.6 92 40.5 State Gov. Empl. 81 9.4 63 9.4 18 9.5 6 2.6 Loc. Gov. Empl. 187 21.7 165 24.6 22 11.6 21 9.3 Self-Employed Worker 24 2.8 24 3.6 0 0.0 0 0.0 Unpaid Family Worker 0 0.0 0 0.0 0 0.0 0 0.0 TOTAL, Employed, 16 years old and over 2,342 1,863 479 311 Employee of Priv. Co. 1,465 62.6 1,119 60.1 346 72.2 126 40.5 Empl. of own Corp. 30 1.3 30 1.6 0 0.0 ' 0 0.0 Fed. Gov. Empl. 181 7.7 146 7.8 35 7.3 158 50.8 State Gov. Empl. 157 6.7 115 6.2 42 8.8 6 1.9 Loc. Gov. Empl. 376 16.1 326 17.5 50 10.4 21 6.8 Self-Employed Worker 133 5.7 127 6.8 6 1.3 0 0.0 Unpaid Family Worker 0 0.0 0 0.0 0 0.0 0 0.0 ADDENDUM: Military Personnel 247 1,244 > Source: Bureau of the Census, 1970 Census, Alaska, special computer runs. 3 Table 64 (continued) Class of Worker Aleutians, Alaska and O. S. 1970 : ALEUTIAN ISLANDS ALASKA TOTAL WHITE NONWHITE TOTAL CLASS OF WORKER Number Percent Number Percent Number Percent Number Percent (Civilians) MALES, Employed, 16 years old and over 609 334 275 54,114 Employee of Private Company 354 58.1 217 65.0 137 49.8 30,080 55.6 Employee of Own Corporation 0 0.0 0 0.0 0 0.0 1,186 2.2 Federal Government Worker 184 30.2 81 24.3 103 37.5 9,261 17.1 State Government Worker 53 8.7 29 8.7 24 8.7 5,066 9.4 Local Government Worker ll 1.8 7 2.1 4 1.5 3,872 7.2 Self-Employed Worker 7 1.1 0 0.0 7 2.5 4,560 8.4 Unpaid Family Worker 0 0.0 0 0.0 0 0.0 89 0.2 FEMALES, Employed, 16 years old and over 316 213 103 35,122 Employee of Priv. Co. 127 40.2 85 39.9 42 40.8 18,686 53.2 Empl. of own Corp. 0 0.0 0 0.0 0 0.0 232 0.7 Fed. Gov. Empl. 146 46.2 112 52.6 34 33.0 5,959 17.0 State Gov. Empl. 43 13.6 16 7.5 27 26.2 4,030 11.5 Loc. Gov. Empl. 0 0.0 0 0.0 0 0.0 4,384 12.5 Self-Employed Worker 0 0.0 0 0.0 0 0.0 1,510 4.3 Unpaid Family Worker 0 0.0 0 0.0 0 0.0 321 0.9 TOTAL, Employed, 16 years old and over 925 547 378 89,236 Employee of Priv. Co. 481 52.0 302 55.2 179 47.4 48,766 54.6 Empl. of own Corp. 0 0.0 0 0.0 0 0.0 1,418 1.6 Fed. Gov. Empl. 330 35.7 193 35.3 137 36.2 15,220 17.1 State Gov. Empl. 96 10.4 45 8.2 $1 13.5 9,096 10.2 Loc. Gov. Empl. ll 1.2 7 1.3 4 1.1 8,256 9.3 Self-Employed Worker 7 0.8 0 0.0 7 1.9 6,070 6.8 Unpaid Family Worker 0 0.0 0 0.0 0 0.0 410 0.5 ADDENDUM: Military Personnel 3,689 . uw Source: Bureau of the Census, 1970 Census, Alaska, special computer runs. Table 65 OCCUPATIONS OF T:IE EMPLOYED ALEUTIAN ISLANDS KODIAK ALASKA OCCUPATION Number Percent Number Percent Number Percent MALE employed, 16 years old and over 609 100.0 1,564 100.0 54,114 99.9 Professional, technical and kindred workers 97 15.9 204 13.0 10,385 19.2 Managers and administrators, except farm 56 9.2 204 13.0 8,238 15.2 Sales Workers 8 1.3 25 1.6 2,331 4.3 Clerical and kindred workers 39 6.4 62 4.0 3,239 6.0 Craftsmen, foremen and kindred workers 183 30.0 336 21.5 13,012 24.0 Operatives, except transport 71 11.7 226 14.5 4,021 7.4 Transport equipment operatives 25 4.1 65 4.2 2,497 4.6 Laborers, except farm 36 5.9 229 14.6 4,650 8.6 Farmers and Farm managers -- -- Said =< 95 0.2 Farm laborers and farm foremen 4 0.7 5 0.3 144 0.3 Service workers, except private household 90 14.8 208 13.3 5,477 10.1 Private household workers -- = 25 -- FEMALE employed, 16 years and over 316 99.8 1,089 100.2 35,122 100.1 Professional, technical and kindred workers 39 12.3 206 18.9 6,988 19.9 Managers and administrators, except farm 19 6.0 58 3 2,053 5.8 Sales Workers 41 13.0 55 5.1 2,595 7.4 Clerical and kindred workers 106 33.5 257 23.6 13,478 38.4 Craftsmen, foremen and kindred workers -- -- 23 2.1 425 1.2 Operatives, except transport 39 12.3 214 19.7 1,477 4.2 Transport equipment operatives -- -- 5 0.5 244 0.7 Laborers, except farm 15 4.7 28 2.6 382 1.2 Farmers and Farm managers -- ne = iad 39 0.1 Farm laborers and farm foremen -- -- - -- 57 0.2 Service workers, except private household 48 15.2 213 19.6 6,385 18.2 Private household workers 9 2.8 30 2.8 999 2.8 Source: U.S. Bureau of the Census 1970b. oad uw nN 50004 45004 40004 3500-4 1500 10004 500 1963 DJ 1964 DU SOURCE: ALASKA WORKFORCE ESTIMATES, ALASKA DEPARTMENT OF LABOR, JUNEAU Figure 165 1965 DU kodi bepar vk 1966 Du 1967 DJ 1968 LEGEND LABOR FORCE ome MONTHLY EMPLOYMENT #8 AVERAGE ANNUAL EMPLOYMENT * UNEMPLOYMENT 3 NONAGRICULTURAL WAGE AND SALARY EMPLOYMENT Du force and empicyment variou dates). 1969 DJ 1970 OU , 1965-1972 (from Alaska 1971 Pr) 1972 DU ayy LEGEND LABOR FORCE mums MONTHLY EMPLOYMENT ¥ 3260. @=—"@ AVERAGE ANNUAL EMPLOYMENT ¥ UNEMPLOYMENT 30004 2 NONAGRICULTURAL WAGE AND SALARY EMPLOYMENT 27504 2500-4 20004 17504 1500 1250 oo | 5004 2504 boos peoeirias J u 1963 DJ 1964 Dy «1965 DY «1966 DJ «1967 Du 1968 Du 1969 Du 1970 Du 1971 Dd 1972 D = SOURCE: ALASKA WORKFORCE ESTIMATES, ALASKA DEPARTMENT OF LABOR, JUNEAU 3 Figure 166. Ale an Islands labor roe and employment, 1963-1972 (from Alaska Depa er t Labor, uc date 455 movement in the average annual employment and the monthly variations around the average. The graphs also illustrate how closely the seasonal movements in the labor force, due to changes in participation rates, match the movements in employment. The fact that the fishing industry is the source of the seasonal variation is confirmed by Figures 167 and 168. In Kodiak, manufacturing, which is actually fish processing, is the only industry with any significant seasonal variation. Fish processing is also the primary cause of seasonal fluctuation in the Aleutian Islands Census Division, but there the pattern is reinforced by a similar fluctuation in the construction industry. Employment by Industry Employment in each of the major industries in the Kodiak area is shown in Table 66 for the period 1961 to 1972. The discussion below outlines the factors which have produced the observed development of each sector. Contract Construction In the early 1960s contract construction accounted for only one percent of the total employment in the Kodiak labor market area. However, the Good Friday earthquake and tidal waves of 1964, which destroyed a major portion of the downtown area, created a boom in the construction industry. Rebuilding homes, buildings, businesses, roads, and harbor facilities was underway within two months after the disaster. Average employment in contract construction in the second half of 1964 was 294 persons. By comparison the average for the same months in 1962 was only 44, The post-earthquake construction peaked in 1965, with an average of 312 persons (13.5 percent of the total employment) working in the industry. Construction employment declined after 1965 but the impact of earthquake related rebuilding was evident through 1968. In 1970 construction employment declined to 1.9 percent of the total employment, a proportion which approached that of the early 1960s. In 1971 the trend reversed and construction employment rose with the beginning of a number of major projects in Kodiak area including a new high school, community college building, bio-dry plant to process cannery wastes, and extensive road work. In 1972 construction employment averaged 125 persons--4.3 percent of the total employment. According to the Kodiak Manpower Center, construction employment in 1973 was high, with Most positions being filled by local residents. It is likely that a five year plan for modernization and expansion of the Kodiak Coast Guard base will continue to keep construction employment at high levels. According to the base public works officer, 6.5 million dollars in construction projects has been authorized for fiscal year 1974. An additional 7.5 million dollars has been requested $56 un ow as a4 a 25 2 ty 1 T T T T T T T T T =m SO TOTAL 5,000 ———— GOVERNMENT | eeseesess MANUFACTURING ae seeeeeess DISTRIBUTIVE IND. 4,500° —*+— CONTRACT CONSTRUCTION | 4,000 3,500+ 3,000 2,500 2,000 1,500 1,000 500 we? — eee ee ee ee ee _—s Ce a eo 1 1 | 1 =i 4 JAN FEB MAR APR MAY JUNE JULY AUG SEPT ocT NOV DEC Figure 167. Kodiak Island total employed workforce by industry and month, 1972 (from Alaska Department of Labor, various dates). -NUMBER OF EMPLOYEES T T T T T T T T T T T 2750+ | —ee—m TOTAL seeseeees GOVERNMENT ———— MANUFACTURING 4 2,500 teseeeeee DISTRIBUTIVE. IND. —-+— CONTRACT CONSTRUCTION 2,250 | 2000+ | ,750F | 1,500 | 1250+ | {~~ 1,000 / ‘ | Ngeeeeet een, acoeetee, aeaasesequsenesanay, / aN ene Ny %e, for" N a \ 750+ 500+ eer TTT. 250b ee access . ne ee El iia el = J 1 | 1 1 J | 1 1 1 1 JAN FEB MAR APR MAY JUNE JULY AUG SEPT OocT NOV DEC figure 168. Aleutian Islands total employed workforce by industry and month, 1972 (from Alaska Department of Labor, various dates). Table 66 NONAGRICULTURAL WAGE AND SALARY EMPLOYMENT BY INDUSTRY KODIAK LABOR AREA 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 TOTAL EMPLOYMENT 1824 1780 1876 1890 2310 2700 2875 2650 2395 2468 2619 2878 Contract Construction 24 28 7" 176 312 291 191 166 84 46 61 125 Manufacturing 606 643 643 492 630 832 1014 811 664 743 768 866 Transportation, Communication, and Public Utilities 79 96 119 124 142 160 226 227 236 216 266 228 Trade . 164 167 160 157 211 324 331 319 326 346 343 355 Service 83* 96* 116* id 196 215 193 165 168 190 241 232 Government 831 719 76S 773 783 823 862 893 836 838 851 821 Other 27 31 73 168 36 55 58 69 81 89 89 251 INDUSTRIAL DISTRIFUTION OF EMPLOYMENT (PERCENT) Contract Construction 1.3 1.6 0 # 9.3 13.5 10.8 6.6 6.3 3.5 1.9 2.3 4.3 Manufacturing 33.2 36.1 34.3 26.0 27.3 50.8 35.5 30.6 27.7 30.1 «9.3 30.1 Transportation, Communication, and Public Utilities 4.3 5.4 6.3 6.6 6.1 5.9 7.9 8.6 9.9 8.8 10.2 7.9 Trade 9.0 9.4 8.5 8.3 9.1 12.0 11.5 12.0 13.6 14.0 13.1 12.3 Service $.1 5.4 6.2 ak 8.5 8.0 6.7 6.2 7.0 7.7 9.2. 8.1 Government 45.6 40.4 49.8 40.9 33.9 39.5 30.0 33.7 34.9 34.0 32.5 28.5 Other 1.5 1.7 3.9 8.9 1.6 2.0 2.0 2.6 3.4 3.6 3.4 8.7 *Includes Miscellaneous **Withheld to comply with disclosure regulations. Source: Alaska Department of Labor, various dates. 8SP 459 for fiscal year 1975, but is subject to congresssional approval. Estimates of construction beyond 1975 are not available. In addition it is anticipated that the base will award 1 million dollars annually for small construction contracts such as road repairs, re-roofing of buildings, and painting. Manufacturing In the Western Gulf of Alaska manufacturing is virtually synonymous with sea food processing. The industry has consistently accounted for 25 to 35 percent of the total employment. The lowest employment levels for manufacturing were recorded following the 1964 Alaskan earthquake. More than half of the island's canneries were concentrated in the city of Kodiak which was one of the areas hardest hit by the disaster. All plants suffered some structural and equipment damage and several were destroyed. The following year average employment in manufacturing remained low, but by 1966, the work force averages approached former levels, and in 1967 employment reached a peak of 1,014. The following two years registered a decline, but beginning in 1970 the total average monthly employment gradually increased to the 1972 total of 866. The impact of the fishing industry has always been understated in Alaska's employment statistics because there have been no reliable estimates of the direct employment in commercial fishing. Available statistics included only those employees covered by unemployment insurance. Beginning in 1972 many commercial fishermen were able to sign up for the unemployment insurance program and have subsequently been added to the work force estimates in the miscellaneous category. According to the Alaska Department of Labor, more than 90 percent of the persons in the miscellaneous category for Kodiak in 1972 are commercial fishermen. This would add nearly 200 persons to the employment in manufacturing shown in Table 66 for 1972. Although the miscellaneous category does not as yet include all of the commercial fishing employment, lumping this category with manufacturing makes it clear that known employment in the fishing industry is more than a third of the total annual employment. Trade and Service Trade and service employment over the past five years has averaged about 20 percent of the total employment. The month to month variation in this sector is minimal and does not follow a consistent pattern from year to year. Trade and service employment increased gradually between 1968 and 1971 and then leveled off in 1972. Average 1972 employment in these industries was 232 persons in service and 355 in trade. Transportation, Communications, and Public Utilities In recent years employment in transportation, communications, and public utilities ranged from eight to 10 percent of total employment. 460 Average monthly employment in these industries remained fairly constant. In 1967 there were 226 persons employed per month and in 1972, 228. Some decline in employment occurs during the winter months but the seasonal variation is not very large. Government In 1961 government employment in the Kodiak area accounted for nearly half of the civilian work force. From 1965 to 1970 the share varied between 30 and 35 percent. On July 1, 1972 the Naval base was closed and the facility was taken over by the Coast Guard. According to the Cosst Guard's public information officer, all civilian employees who were working for the Naval base at the time of closure were offered positions with the Coast Guard. Nonetheless, current civilian employment on the base is 90, only about one-third of the previous employment of the naval base. As a result, the government share of total employment dropped below 30 percent in 1972. Although total government employment declined as the naval base was phasing out, much of the slack was taken up by an increase in state and local government employment. Between 1969 and 1972 state and local government employment increased 42 percent. Kodiak is the regional center for state government in the Western Gulf and Aleutian areas. Agency offices here include the State Departments of Fish and Game, Health, Highways, Labor, Public Safety, and Public Works. Most of the local government employment is also concentrated in Kodiak which is the headquarters for the Kodiak Island Borough. Teachers and school employees in Kodiak and the smaller villages are sill borough employees and they constitute a major portion of the local government employment. In addition to the borough government, the city of Kodiak maintains a local government which employees police, fire, public works, harbor, sanitation, and administrative personnel. INCOME AND COST OF LIVING Distribution of Income In 1969, median family income in the Kodiak Census Division was 11,200 dollars (Table 67), about 10 percent below the median family income for the state as a whole. As shown in Table 67, the distribution of income in the Kodiak Island Borough is quite similar to the statewide pattern with 62 percent of the families having incomes in excess of 10,000 dollars. About 67 percent of the white families in the Kodiak Island Borough have incomes of 10,000 dollars and above, a figure equivalent to the statewide average for whites (Table 67). Among nonwhite families 43 percent have incomes over 10,000 dollars, much lower than the white average, but considerably higher than the statewide average of Table 67 Income of Families 1969 KODIAK KODIAK ISLAND BOROUGH KODIAK STATION TOTAL WHITE NONWHITE TOTAL Number Percent Number Percent Number Percent Number Percent ALL FAMILIES 1,449 1,136 313 562 Less than $1,000 13 0.9 8 0.7 5 1.6 11 2.0 $1,000-1,999 29 2.0 16 1.4 13 4.2 13 2.3 2,000-2,999 63 4.316.8 32 2.814.1 31 9.9 26.9 0 0.0 10.3 3,000-3,999 47 3.2 42 3.7 5 1.6 9 1.6 4,000-4,999 93 6.4 63 5.5 30 9.6 25 4.4 §,000-5,999 64 4.4 39 3.4 25 8.0 79 14.1 6,000-6,999 37 2.6 32 2.8 5 1.6 64 11.4 7,000-7,999 69 4.8 21.6 41 3.618.8 28 8.9 30.6 60 10.7 47.2 8,000-8,999 66 4.6 40 3.5 26 8.3 31 5.5 9,000-9,999 75 5.2 63 5.5 12 3.8 31 5.5 10 ,000-11,999 143 9.9 130 11.4 13 4.2 74 13.2 12,000-14,999 294 20.3 232 20.4 62 19.8 78 13.9 15,000-24,999 352 24.3 61.7 314 27.6 66.8 38 12.142.5 84 14.9 25,000-49 ,999 104 7.2 84 7.4 20 6.4 3 0.5 50,000 or more 0 0.0 0 0.0 0 0.0 0 0.0 Median Family Income $11,166* *Kodiak Census Division Source: U.S. Bureau of the Census, 1970 Census, Alaska, special computer runs; U.S. Bureau of the Census 1970b. 19V Table 67 (continued) Income of Families 1969 Aleutian Islands, and Alaska ALEUTIAN ISLANDS ALASKA TOTAL WHITE NONWHITE TOTAL WHITE NONWHITE Number Percent Number Percent Number Percent Percent Percent Percent ALL FAMILIES 1,080 664 416 Less than $1,000 8 0.7 0 0.0 8 1.9 2.2 1.6 5.6 $1,000-1,999 26 2.4 6 0.9 20 4.8 23 1.4 7.5 2,000-2,999 24 2.218.5 7 1.114.1 17 4.1 2.714.1 1.79.9 8.3 37.7 3,000-3,999 71 6.6 33 5.0 38 9.1 3.2 2.2 8.6 4,000-4,999 71 6.6 47 7.1 24 5.8 3.7 7.0 3.7 5,000-5,999 83 7.7 58 8.7 25 6.0 5.0 4.3 8.8 6,000-6 ,999 102 9.4 69 10.4 33 7.9 4.9 4.6 6.8 7,000-7,999 98 9.141.4 66 9.9 46.3 32 7.7 33.6 4.6 23.5 4.5 22.4 5.2 30.1 8,000-8,999 103 9.5 76 11.4 27 6.5 4.7 4.7 4.9 9,000-9,999 62 5.7 39 5.9 23 5.5 4.3 4.3 4.4 10,000-11,999 144 13..3 93 14.0 51 12.3 10.2 12,000-14,999 147 13.6 107 16.1 40 9.6 14.3 15,000-24,999 117 10.8 39.9 45 6.8 39.6 72 17.3 40.6 28.2 62.2 67.7 32.1 25,000-49 ,999 24 2.2 18 2.7 6 1.4 8.7 50,000 or more 0 0.0 0 0.0 0 0.0 0.8 Median Family Income $8,553 $12,443 $13,464 Source: U.S. Bureau of the Census, 1970 Census, Alaska, special computer runs; U.S. Bureau of the Census 1970b. > a nN 463 only 32 percent for nonwhites. At the lower income levels, less than 5 percent of Kodiak's white families have incomes below 3,000 dollars, compared to 16 percent for Native families. However, for the state as a whole more than 21 percent of the nonwhite families have incomes less than 3,000 dollars. The median income in the Aleutian Islands Census Division is 8,500 dollars, nearly a third lower than the state average (Table 67). The difference in income level is so large that it is difficult to make comparisons between the distributions of income. Obviously, a large proportion of the families in the Aleutian Islands region have low incomes and a small proportion have high incomes. Only 13 percent of the families in the Aleutians have incomes above 15,000 dollars compared to 38 percent for the state. In the Aleutian Islands there appears to be less disparity between the incomes of white and nonwhite families with both having roughly 40 percent in the above 10,000 dollars income range (Table 67). The widest differences are in the low income ranges where only 14 percent of the whites earn less than 5,000 dollars compared to 26 percent for nonwhites. Since a majority of the white families in the Aleutians military dependents, it is not surprising that the white income distribution most closely resembles Kodiak Station. If military benefits were taken into account, the difference between white and nonwhite incomes would be greater. Still, as in Kodiak, incomes of nonwhite families in the Aleutian Islands are substantially higher than statewide averages for nonwhites. Public Assistance Income State public assistance, U. S. Bureau of Indian Affairs general assistance, and Food Stamps are the three major forms of public assistance available to local residents. The state public assistance programs include payments for old age assistance, aid to the blind, aid to the disabled, and aid to dependent children. Table 68 shows the number of cases and the dollar payments in each category for October of 1970, 1971, and 1972. For October 1972 the total amount of state public assistance in the Western Gulf region was 36,315 dollars. Comparable statistics are not avilable for years prior to 1970, because regulations for receiving assistance under these programs were changed in that year. Between 1970 and 1972 the number of Kodiak residents receiving funds from all of these progams increased from 120 to 191. At the same time, the number of recipients in the Alaska Peninsula region declined from 30 to 22. The 1970 census reported that less than three percent of the families in Kodiak were receiving public assistance (U.S. Bureau of the Census 1970b). In the Aleutians, despite the very low income levels prevailing there, less than 1.5 percent of the families were receiving any form of public assistance. Table 68 MONTHLY PUBLIC ASSISTANCE" ** WESTERN GULF: OF ALASKA OCTOBER 1970, 1971, 1972 Number of Cases Dollar Payments QAA AB AD AFDC TOTAL OAA AB AD. AFDC TOTAL KODIAK 1970 29 2 24 ~= «65 120 $3,038 $435 $3,573 $13,108 $20,154 1971 35 3 19 66 123 3,471 488 3,077. 14,881 21,917 1972 46 3 31 111 191 4,344 497 5,791 21,468 32,100 ALEUTIANS (Communities in Western Gulf) 1970 12 #1 3 #414 30 1,868 169 425 4,014 6,476 1971 16 1 3 = 10 30 2,987 .203 459 3,372 6,321 1972 12 2 2 6 22 1,525 273 257 2,160 4,215 WESTERN GULF 1970 41 3 27 79 150 4,906 604 3,998 17,122 26,630 1971 51 4 22 76 153 6,458 691 3,536 18,253 28,238 1972 $8 5 33 117 231 5,869 770 6,048 23,628 36,315 *OAA=old age assistance, AB-aid to the blind, AD=aid to the disabled, AD=aid to dependent children. **Combination of statistics for Kodiak District and Aleutian Communities (Anchorage District) in Western Gulf. Source: Alaska Department of Health and Social Services, various dates. - 464 465 U.S. Bureau of Indian Affairs general assistance is available only to Natives. In 1968 these payments in the Western Gulf totaled 110,585 dollars (Table 69). In 1969 and 1970 the amount of assistance was cut to half of the 1968 level. Since 1970, payments have increased to the 1972 total of 172,018 dollars which represents assistance to 166 cases. The Food Stamp Bonus Coupon program receives funding from the U.S. Department of Agriculture, but is administered by the State. Administration of this program for Alaska Peninsula recipients is handled through the Anchorage office of the Division of Family and Children's Services. The Kodiak office of the Division of Family and Children's Services distributed nearly 200,000 dollars in food stamps in the Kodiak area during 1971 (U.S. Office of Economic Opportunity 1971). Earnings and Wage Rates The earnings data in Table 70 show that the observed differences in regional incomes are not due solely to differences in the relative importance of various occupations. There is a consistent earnings differential in virtually all occupational categories. In Kodiak, males typically earn about 10 percent less than the statewide averages. There is considerable variation in the size of this gap with operatives making 30 percent less and laborers actually earning slightly more than the state average. Female earnings in Kodiak average 25 percent less than the state levels. However, in this case a substantial part of the gap is due to the difference in occupational mix. A relatively large share of the female employees in Kodiak are workers in canneries where the annual pay is low, in part because of the seasonal nature of the industry. The work force in the Aleutians consistently earn less in the various occupational categories, and the gap is much wider than in Kodiak. On the average, males earn 25 percent less than the state average and females earn nearly 50 percent less. Table 71 gives Kodiak area average monthly wage rates by industry for the 1960-1972 period. In general, wage rates have increased throughout this period at an average annual rate of 5.7 percent. The average monthly wage in 1972 was 845 dollars compared to 436 dollars in 1960, an increase of 95 percent. The following discussion of wage rates lists the industries in descending order from highest average monthly wage in 1971 to lowest. Contract construction has consistently averaged the highest wage rates of any industry in the Kodiak area. Beginning in 1965, the average monthly wage rates for construction were more than 1,000 dollars during every year except 1967. No other industry in Kodiak has averaged more than 1,000 dollars in any year. Construction wage rates rose from an average 341 dollars in 1960 to 1,556 dollars in 1972. State and local government has shown a relatively rapid increase in wages between 1964 and 1972. In this interval, state and local government wages rose from a monthly average of 549 dollars to 910 dollars, an average annual increase of 6.5 percent. Table 69 BUREAU OF INDIAN AFFAIRS GENERAL ASSISTANCE WESTERN GULF OF ALASKA COMMUNITIES FISCAL YEARS 1968-1972 F. Y. 1968 F. Y. 1969 Communi ty Amount Cases Amount Cases eutian Islands (Communities in Western Gulf) Belkofski $ 1,900 2 $ 110 Chignik 5,202 6 - - Chignik Lake 10,818 8 6,383 9 Chignik Lagoon 958 3 Cold Bay - - - - Ivanof Bay 8,027 6 725 1 King Cove 2,291 3 200 1 Pavlof Harbor 1,100 1 - - Perryville 13,093 15 - - Port Moller - - 4 = Sand Point 2,239 2 357 2 Subtotal - Aleutian $ 4,628 “4 3 7,775 “14 Kodiak Island Afognak - - + * Akhiok 13,351 13 6,711 7 Karluk 4,450 8 3,150 3 Kagayuk - - - - Kodiak 10,109 20 4,885 12 Larsen Bay 5,564 5 3,334 3 Old Harbor 25,082 32 20,004 20 Ouzinki 1,920 2 2,054 3 Port Lions 4,481 7 231 1 Subtotal - Kodiak $64,957 ~87 40,369 “49 TOTAL $ 110,585 133 $ 48,144 63 Source: F. Y. 1970 Amount Cases $ - 8,050 505 663 4,290 628 dora. tRreare 6,756 348 11,748 4,007 18,127 1,063 224 $ 56,409 oo N N Ww RPurue! wot F. Y. 1971 Amount Cases $ 1,159 369 3,659 592 700 RRA R 1,808 852 1 $9,175 “9 11,925 7,046 42,575 800 26 ,360 8,550 9 » 256 $ 106,431 U. S. Bureau of Indian Affairs, Anchorage District Office files. F. Y. 1972 Amount Cases $ 621 1,563 8,930 1,442 620 1,250 695 904 3,876 319,901 23,787 23,807 50,067 7,759 33,247 13,273 240 —152,180 $ 172,081 WARPWI NI RB ROUF al 14 24 55 26 12 138 166 996 467 Table 70 EARNINGS BY OCCUPATIONAL GROUPS 1970 Kodiak Aleutian Islands Census Division Census Division Alaska Median earnings for selected occupat ion groups MALE, 16 years old and 10,214 8,519 11,242 over with earnings Professional and managerial 12,929 11,283 13,796 Craftsmen and foremen 11,111 9,346 12,098 Operatives 6,591 4,333 9,566 Laborers 6,885 6,333 6,747 FEMALE, 16 years old and 3,576 2,477 4,818 over with earnings Clerical and kindred workers 4,406 2,600 5,296 Operatives 2,287 1,650 2,274 Source: U.S. Bureau of the Census 1970b. Table 71 Kodiak Area Nonagricultural Average Monthly Wage 1960 - 1972 Industrial Classification 1960 1961 1962 1963 19642 1965 1966 1967 1968 1969 1970 1971 1972 Total Nonagricultural Industries $436 $476 $527 $504 $579 $607 $620 $559 $636 $657 $665 $714 $845 Mining * * * * * * * * * * * * * Contract Construction 341 638 848 680 913 1066 1167 965 1153 1133 1100° 1229 1556 Manufacturing 474 S02 S48 521 607 553 531 441 525 576 601 641 630 Transportation, Commuications and Utilities 399 450 491 532 607 628 668 544 631 615 671 709 1047 Wholesale and Retail Trade 373 427 477 527 529 580 572 577 594 588 574 596 660 Finance, Insurance and 4 Real Estate 439 S07 513 482 495 517 488 500 575 564 580 649 * Services and Miscellaneous 247 291 356 365 433 463 483 470 449 435 460 491 569 Federal Government NA NA NA NA 469 469 525 570 638 689 673 691 898 State and Local Government NA NA 281 NA 549 621 647 687 703 785 811 922 910 *Not shown to avoid disclosure of information for individual firms. lpor three quarters only. The Ist Quarter 1964 Statistical Quarterly contained employment and earnings data, by industry and by area, for all nonagricultural workers in wage and salary employment, including those not covered by unemployment insurance. Previous issues contained data only for covered workers. These new data appear in all subsequent issues of the Statistical Quarterly. 3ist Quarter 1960 not shown to avoid disclosure. 4lst Quarter 1960 only included to avoid disclosure. (Source: Alaska Department of Labor, Statistical Quarterly, 1960-72.) 89b 469 Transportation, communications, and public utilities wages increased steadily between 1960 and 1966, declined during 1967-69, and have increased since that time. Average wages in the industry rose 78 percent between 1960 and 1971 and then jumped by 48 percent in 1972 alone. The average wage in 1972 was 1,047 dollars, second only to contract - construction. Federal government wages, which had remained virtually constant between 1968 and 1971, increased by 30 percent in 1972. This nearly eliminated the disparity between the average wages paid to federal government workers and wages paid in state and local government positions. In 1972 the state and local government average wage was 910 dollars and the federal government wage was 898 dollars. Finance, insurance, and real estate industries have had erratic variations from year to year; however, the overall trend has been a moderate increase from an average 439 dollars in 1960 to 649 dollars in 1971. Wholesale and retail trade wages increased from 373 dollars in 1960 to 580 dollars in 1965. From then to 1971 they increased very little, but rose by 11 percent in 1972 to reach a level of 660 dollars. Manufacturing (fish processing) ranks first in percentage of persons employed, but next to lowest in average monthly wages. Wages in manufacturing have been the most unstable of Kodiak industries, a reflection of the cyclic nature of seafood processing. In 1960 the average monthly manufacturing wage was 474 dollars and it increased to 607 dollars in 1964; however, in 1967 the average wage declined to 441 dollars. Since 1967 manufacturing wages have risen to 630 dollars in 1972. Services and miscellaneous industries ranked last in average monthly wages despite the fact that between 1960 and 1972 average montly wages more than doubled, going from 247 dollars to 569 dollars. That is still a third lower than the average wage in the Kodiak area. Cost of Living The Quarterly Report on Alaska Food Prices is the only data series which provides direct information on the cost of living in Kodiak relative to other areas (Marsh 1973). The report is based on a "market basket" of 45 food items which are surveyed nationwide by the U. S. Department of Agriculture (Table 72). The cost of this market basket is used to calculate food price ratios between Seattle and selected Alaska communities. These ratios for Kodiak Anchorage, Fairbanks, and Juneau from 1957-1973 are shown in Table 73. Prior to 1960, food prices in Alaska were based almost exclusively on a city's proximity to the port of Seattle. Thus, in the late 1950s Kodiak had lower food prices than either Anchorage or Fairbanks, while Southeastern Alaska communities such as Juneau had the lowest food prices in the state. As the state grew during the 1960s, prices rose much less rapidly in Anchorage and Table 72 AVERAGE RETAIL PRICES OF 45 FOOD ITEMS IN SELECTED ALASKA CITIES 470 JUNE 1973 Fair- Food Item Unit Juneau Kodiak Anchrg. banks Bethel _Nome Flour. . . 2 se. + . .10 1b. 1.77 2.34 1.76 1.93 2.44 2.58 Rice... 2 ee geen 28 oz. 1.24 1.22 1.22 1.12 1.49 1.53 Corn Flakes... .... 18 oz. +58 +62 -48 -64 75 +75 Bread, white... . . «14 1b. 56 259 58 -62 79 - 86 Round steak. ..... +1 1b. 1.90 1.88 1.54 1.98 2.85 2.58 Chuck Roast... 2... +1 1b. 1.20 1:35 1.09 1.28 2.45 1.77 Hamburger. . 2... ] . .l Ib, 99 1.18 94 1.06 1.67 1.23 Pork chops. .....- 1 Ib, 1.60 1.64 1.71 1.70 1.95 3522 Bacon... 1... eee -1 1b. 1.37 1.54 1.42 1.36 1.91 1.75 Wieners. . 2... ee. ee 1 lb 1.20 1.30 1.03 1.04 1.63 1.39 Frying chicken. .... 1 1b. .99 96 -79 +93 1.24 1.21 Funa-fish,—.+—+ 6% oz. 58 -64 -57 62 +69 © - 84 Milk, fresh... 2... 2. 45 gal. 98 1.11 -98 1.08 1.57 1.75 Ice cream. ...... os gal. 1.27 1.37 1.16 1.38 2.12 1.97 Butter... 1 2 2 eae 1 1b. 96 1.10. +94 -98 1.61 1.35 Milk, evap... .... 14; oz. +26 +32 +26 -28 -35 34 Milk, powdered... . 12 qt. 2.66 2.23 2.48 2.05 2.83 3.40 Eggs, freshe. 2... 1 doz. 84 83 «73 -82 1.12 1.12 Orange juice, frozen . 12 oz. -58 -80 -80 +76 , 80 1.14 Apples... ee eee 1 1b. 45 54 49 54 72 .72 Bananas. ....... +1 db. 234 -49 .29 -36 «52 -62 Oranges... 2.2.2... 1 1b. 31 ~42 33 42 51 -59 Potatoes... 2... eee 1 1b. -18 14 ~22 ~22 231 +34 Onions... ... eee 1 1b. 231 .39 36 58 -50 56 Carrots. ........1 Ib. 37 «39 36 38 «52 -58 LOGEC ecient“ L..1by -62 +64 +64 66 +79 +73 Cabbage. . ...... 1 Ib. +36 37 -30 -40 -46 49 Tomatoes, fresh. . .. .1 1b. +72 +79 ~62 ~84 1.13 -95 Grapefruit juice... .46 oz. 84 «89 -80 -82 1.06 1.11 Tomato juice... .. .46 oz. -61 +62 -60 +66 -97 -99 Pears ...... No. 2% can 64 «72 74 28 74 - 82 Peaches. . . .. . No. 24 can 63 74 257 63 -80 77 Fruit cocktail . . . .303 can «41 48 41 245 55 54 Com: . 2. ew ee we 303 can 32 36 -29 -40 343 47 Tomatoes, canned . . .303 can 37 -40 -36 ~42 47 ~52 Baby foods . . .. . .4%-5 oz. «1S 18 1S ~22 -23 -22 Coffee. ........ 3° 1b. 3.26 3.51 3.76 3.49 4.38 3.91 Salad or cooking oil . 48 oz 1.54 1.80 1.42 1.54 2.17 2.31 Margarine. ...... .1 Ib. 239 +42 -30 -53 49 45 Mayonnaise ....... 1 qt. 94 1.14 -88 -96 1.43 1.38 Cola drink . ... . . 6-pack 1.06 1.30 1.18 1.26 1.84 1.78 Beans, dried. ..... 2 1b. -61 -80 76 -61 ~62 ~82 Sugar... 2... eee 10 1b. 1.92 2.30 1.72 1.79 2.78 2.67 Tomato soup. ..... 10%; oz. 19 +22 -20 -20 +26 +31 Cr. of Mushroom soup . 10% oz. +24 -26 -23 25 235 ~35 TOTAL* 39.31 43.31 38.46 41.04 55.29 54.28 TOTAL** 27.91 30.91 27.12 29.83 40.90 38.89 % of Scattle**, a 121 134 118 129 177 169 Total, March, 1973** 26.80 29.75 26.90 28.79 41.02 37.64 Total, June, 1972** 24.73 27.73 25.05 27.07 38.59 37.00 * New revised food list ** Old food list *k* Based on May, 1973 U.S. Department of Labor, BLS "Retail Food Prices by Cities" Source: Marsh 1973. 471 Table 73 FOOD PRICES IN SELECTED ALASKA CITIES AS PERCENT OF SEATTLE 1957-1963 KODIAK ANCHORAGE FAIRBANKS JUNEAU 1957 131 136 154 123 1958 128 136 149 121 1959 129 133 148 123 1960 134 130 149 121 1961 133 129 143 118 1962 130 128 140 119 1963 130 128 143 119 1964 129 128 141 120 1965 136 132 148 131 1966 133 133 146 128 1967 134 132 144 127 1968 134 127 141 126 1969 132 125 140 127 1970 136 120 138 119 1971 137 124 136 121 1972 135 121 129 121 1973* 135 120 130 122 *Based on first and second quarters only. e@ Source: Marsh 1973. 472 Fairbanks than in Kodiak and Seattle. As the size of the market expanded in Alaska's urban centers, it led to increased competition among retail grocers, larger volume buying and more efficient merchandising (Marsh 1973). Compared to Anchorage and Fairbanks, Kodiak's growth has been moderate. One large grocery store supplies most of the food for the city of Kodiak and for a number of the villages on Kodiak Island. There are no competitive national grocery chains in the area. In June of 1973 food prices in Kodiak were 14 percent higher than in Anchorage and 4 percent higher than in Fairbanks. In addition to the data on food prices, there is one other recent piece of information concerning the cost of living in the Western Gulf region. In 1972 the Alaska Division of Personnel conducted a suvery in various parts of Alaska to determine the costs of housing and food for state personnel (Alaska Department of Administration 1972). The survey measured food and beverage purchases (exclusive of alcoholic beverages, tobacco, and non-food products) and made adjustments for special diets, hunting, fishing, gardening, or maintenance of livestock. Housing expenditures included rent, mortgage payments, utilities, taxes, and insurance. The survey concluded that state employee food expenditures in Kodiak averaged 1,163 dollars per person, about 20 percent higher than the Anchorage figure and statewide average (Table 74). Average annual housing expenditures of 1,132 dollars per person in Kodiak were seven percent higher than the state average, but five percent less than Anchorage. But the houses in Kodiak tended to be smaller than average so housing costs per square foot were found to be nine percent higher than statewide and 21 percent higher than Anchorage. Furthermore, the condition of housing in Kodiak was found to be lower than in Anchorage or 21 percent is actually an underestimate of the true differential in the cost of housing. Based on the study's findings, the Division of Personnel recommended that Kodiak employees should receive three to four salary steps above Anchorage, that would amount to about a 15 percent cost of living adjustment for state employees in Kodiak (Alaska Department of Administration 1971). HOUSING AND PUBLIC SERVICES Housing Kodiak Urban Area In terms of the facilities offered, the quality of housing in Kodiak area appears adequate. The 1970 Census of Housing estimated that 93 to 95 percent of the 2,500 housing units in the Kodiak Census Division had hot and cold running water, flush toliets, bathtubs or showers, and complete kitchens (Table 75). In the city of Kodiak the 1970 census estimated that 99 percent of the homes had these facilities. These statistics for such facilities are comparable to the national averages and are considerably higher than the statewide average of 85 percent. On the other hand, the census data indicate that the number of persons per room in Kodiak is higher than average. Furthermore, a 1972 study by Table 74 COSTS OF FOOD AND HOUSING FOR STATE EMPLOYEES 1972 KODIAK STATEWIDE ANCHORAGE KODIAK/STATE KODIAK/ANCHORAGE RATIO RATIO HOUSEHOLD PERSON HOUSEHOLD PERSON HOUSEHOLD PERSON HOUSEHOLD PERSON HOUSEHOLD PERSON Average Annual Food Expenditures $3,862 $1,163 121 119 130 120 $3,185 $ 979 $2,960 $ 971 Average Annual . Housing Expenditures 3,756 1,132 109 107 103 95 3,438 1,055 3,644 1,196 Average Ilousing cost per square foot $3.86 -- 109 -- 121 -- $3.54 -- $3.19 -- Source: Alaska Department of Administration 1972. £Ly Table 75 HOUSING CHARACTERISTICS KODIAK CENSUS DIVISION 1970 KODIAK ALASKA TOTAL RURAL TOTAL RURAL U.S. Number Percent Number Percent Percent Percent Percent Total Population 9,409 2,498 All year round housing units 2,536 100.0 742 100.0 100.0 100.0 100.0 POPULATION pop. in housing units 1970 8,364 2,392 276,918 143,656 per occupied unit 3.5 3.5 3.5 3.8 owner 3.7 3.8 3.8 4.0 renter 3.4 2.9 3.2 3.3 Piped Water in Structure Fst and cold 2,372 93.5 584 78.7 85.8 72.7 95.2 Cold only 90 3.5 84 11.3 2.6 4.7 2.3 None 74 2.9 74 10.0 11.6 22.5 2.4 Flush Toilet For exclusive use of household 2,415 95.2 630 84.9 85.3 72.7 95.9 Also used by another household 9 0.4 - - 1.1 0.9 1.0 None 112 4.4 112 15.1 13.6 26.4 4.0 Bathtub or Shower For. exclusive use of household 2,388 94.2 602 81.1 84.9 72.2 94.2 Also used by another household 4 0.2 - - 11 1.3 1.0 None 144 5.7 140 18.9 14.0 26.9 4.8 Complete Kitchen Facilities Tor exclusive use of household 2,357 92.9 575 77.5 85.4 72.9 95.4 Also used by another household 3 0.1 - - 0.3 0.3 0.2 No complete kitchen facilities 176 6.9 167 22.5 14.4 26.8 4.4 Rooms T room 98 3.9 45 6.1 9.2 13.5 1.9 2 rooms 261 10.3 99 13.3 10.6 11.7 3.3 3 rooms 343 13.5 133 17.9 14.8 13.4 11.2 4 rooms 766 30.2 229 30.8 22.4 20.9 20.9 5 rooms 576 oee7 101 13.6 20.9 19.7 24.9 6 rooms 352 13.9 103 13.8 11.6 10.8 19.9 7 rooms 94 3.7 23 3.1 5.6 5.5 9.4 8 rooms or more 46 1.8 9 1.2 4.9 4.7 8.1 (Continued) bly Table 75 (Continued) HOUSING CHARACTERISTICS - Persons All occupied units 1 person 2 persons 3 persons 4 persons 5 persons 6 persons 7 persons 8 persons or more Persons Per Room AII occupied units 1.00 or less 1.01 - 1.50 1.51 or more Bedrooms All year-round units None 1 2 3 4 or more House Heating Fuel All occupied units Fuel oil, kerosene, etc. Electricity Other fuel Water Heating Fuel tility gas Fuel oil, kerosene, etc. Electricity Bottled, tank, or LP gas Other fuel None Kodiak Census Division 1970 KODIAK ALASKA Number Percent Number Percent Percent Percent 2,384 100.0 677 100.0 100.0 100.0 264 11.1 113 16.7 13.7 12.9 642 26.9 192 28.4 24.7 22.2 401 16.8 66 9.7 17.3 16.0 436 18.3 104 15.4 17.1 16.5 304 12.8 78 11.5 12.1 13.0 173 7.3 60 8.9 7.1 8.3 90 3.8 36 5.3 4.5 5.9 74 3.1 28 4.1 3.6 5.4 2,384 100.0 677 100.0 100.0 100.0 1,934 81.1 502 74.2 81.0 73.9 300 12.6 91 13.4 10.9 11.3 150 6.3 84 12.4 9.0 14.9 2,625 100.0 763 100.0 100.0 100.0 99 3.8 61 8.0 9.9 13.6 572 21.8 235 30.8 22.9 21.4 1,096 41.8 266 34.9 30.0 28.3 790 30.1 181 23.7 27.6 27.0 68 2.6 20 2.6 9.6 9.7 2,535 100.0 719 100.0 100.0 100.0 2,416 95.3 719 100.0 56.6 70.8 21 0.8 - - 4.8 5.4 98 3.9 - - 3.2 1.2 23 0.9 - - 22.1 10.0 1,390 54.8 461 64.1 23.9 25.9 556 21.9 84 11.9 32.5 32.8 392 15.5 63 8.8 5.2 6.7 63 2.5 - - 1.9 0.3 111 4.4 111 15.4 11.3 22.7 (Continued) U.S. Percent 100. NOeOO PNAIWORNADS 100. bh N PNCOoO DALPuowahro N wn woONOHOr SLv Table 75 HOUSING CiiARACTERISTICS - Kodiak Census Division 1970 (Continued) KODIAK TOTAL ~~ RURAL Number Percent Number Cooking fuel Utility gas 18 0.7 > Electricity 1,386 54.7 193 Bottled, Tank or LP Gas 753 29.7 248 Fuel oil, kerosene, etc 378 14.9 278 Clothes Washing Machine Wringer or spinner 246 9.7 177 Automatic or semi-automatic 1,984 78.2 400 None 305 12.0 142 Clothes Dryer as heate 123 4.9 65 Electrically heated 1,569 61.9 243 None 843 33.2 411 Dishwasher Yes 326 12.9 36 No 2,209 87.1 683 Home Food Freezer Yes 1,305 51.5 388 No 1,230 48.5 331 Television (number of sets) I 1,654 65.2 282 2 or more 391 15.4 55 None 490 19.3 382 Battery-Operated Radio Yes 2,121 83.6 554 No 414 16.3 165 Source: U.S. Bureau of the Census 1970c, 1970d. 26. 34. 38. 24, 55. 19, 9. 33. 57. 5. 95. 54. 46. 39. 7. 53. 77. 22. Percent RAM oo oo NoOeo NDAD IW o or ALASKA Percent Percent 3.1 9.6 58.9 42.5 18.2 28.2 7.1 12.9 8.5 14.7 58.5 57.1 33.0 28. 4.2 4.8 48.3 46.0 47.5 49.2 21.9 17.2 78.1 82.8 41.3 47.8 58.7 52.2 59.6 51.7 19.3 12.9 21.1 35.4 85.4 84.5 14.6 15.5 9Lb 477 the Alaska Department of Administration, Division of Personnel, concluded that the homes of state employees in Kodiak were smaller and more crowded than the homes of state employees elsewhere (Alaska Department of Administration 1972). Although the quality of housing in Kodiak is quite high, the amount is barely sufficient for the growing community. The Community Economic Development Committee, for example, notes that there is now a major housing shortage in the Kodiak urban area (Kodiak Island Borough 1973). In October 1973 ads in the local newspaper indicated that there were no homes or apartments for sale or rent in Kodiak. ! Many of the homes in the city of Kodiak were built by the government in the early 1940s to house Naval personnel. Later, when housing was built on the base, the city homes were rented to Kodiak residents. In 1970 the houses were sold to a Kodiak developer, and after renovation, the homes were sold at prices ranging from 13,000 to 19,000 dollars. In 1973 a 1.7 million dollar apartment complex was completed on Alaska State Housing Authority land in the Kodiak urban renewal area. The complex contains 66 one, two, and three bedroom apartments with rents ranging from 260 dollars to 320 dollars per month. The Apartments have had full occupancy since they opened. 3 The Kodiak Coast Guard base has 575 housing units which serve as quarters for military and civilian personnel. The housing was built in the 1940s, but most units have been remodeled and supplied with modern appliances and furnishings.* In 1973 the Coast Guard contemplated moving 50 civilian employees and their families to the city of Kodiak to allow more room for additional military families. Due to the housing shortage in Kodiak they were not able to make the move.» Other Western Gulf Communities In the villages on Kodiak Island, both the quality and the availability of housing varies widely. The Alaska State Housing Authority described the housing at Old Harbor as in "acutely short supply" with more than larry Grober, Kodiak Island Properties, October 1973. Personal communication. 2Ipid. 3wayne Cherrier, Cherrier, King, Cherrier, October 1973. Personal communication. 4H.Z. Parker, public information officer of Kodiak Coast Guard Station. October 1973. Personal communication. SLarry Broaber, Kodiak Island Properties, October 1973. Personal communication. 478 one family living in many of the units (Tryck, Nyman and Hayes 1968). Although the homes are overcrowded, Old Harbor's housing is in good condition. All of the homes were built by the U. S. Bureau of Indian Affairs after the original town was destroyed in the 1964 earthquake. However, Old Harbor's new housing has been criticized on the following grounds: The redevelopment at Old Harbor has been cited by the American Institute of Architects as an example of very poor esthetic planning. Although Old Harbor is located in a beautiful setting which provides an opportunity to develop an imaginative street pattern and architectural treatment of houses to fit the scenery. A gridiron street pattern was established and the houses are of identical box-like design. (Tryck, Nyman and Hayes 1968). All the housing in Port Lions and a large part of the housing in Quzinkie was also built after the earthquake. A number of Ouzinkie homes are still in poor condition and it is anticipated that 10 new homes financed under the government's Turnkey III program will be built in the community within the next year.1 The community of Kaguyak was destroyed in the 1964 earthquake and its residents were relocated in new homes built for them by the U.S. Bureau of Indian Affairs in the nearby village of Akhiok. Apart from these homes, the housing in Akhiok is generally substandard. A majority of the housing at Larsen Bay and Karluk is also in poor condition. The Alaska State Housing Authority described several homes in Karluk as "extremely deteriorated and unsafe for occupancy" (Tryck, Nyman and Hayes 1968). In spite of the poor housing conditions and the shortage of housing in most of the Kodiak villages, representatives of the Native corporation see little possibility that the situation will be remedied within the next two to three years. They have attempted to fund housing through a variety of state and federal programs, but have been largely unsuccessful. 2 Housing in most of the small Native villages on the Alaska Peninsula portion of the Western Gulf is likewise in poor condition, overcrowded, and in short supply. However, in Cold Bay the housing which is provided for government workers and airline personnel is generally good.3 The houses at King Cove are in good condition, but smaller than the average size of homes in urban Alaska (Alaska State Housing Authority 1968). The Alaska State Housing Authority described the housing at Sand Point as an "unusually high quality" by Alaskan standards and further noted: lajlen Panamarofn, Koniag, Inc., October 1973. Personal communication. 2tpid. 3porothy Jones, Sociologist, Institute of Social, Economic, and Government Research, University of Alaska, October 1973. Personal communication. Most homes are well constructed and well maintained, making this an extremely attractive looking community. With the difficulties involved in ordering building supplies out of Seattle and with no local building contractor, the condition of Sand Point's housing is even more impressive. The housing in the town's new subdivision is superior to most Anchorage subdivisions (Alaska Consultants 1970). This description does not apply to all homes in Sand Point as there are still a number of residents living in Quonset huts and other substandard housing. In 1969 the U. S. Public Health Service conducted a survey of homes in Sand Point and did find that most had a full range of facilities and adequate space (Alaska Consultants 1970). Public Services Medical Care The only hospital in the Western Gulf of Alaska is located in the city of Kodiak. It is owned by the borough but administered by the Grey Nuns of the Sacred Heart. The hospital is a modern facility, built in 1969, which has 26 beds plus a nursery. The average patient load in 1972 was 50 percent of capacity and the hospital administrator estimated that the 1973 patient load would average 55 percent of capacity.! Ina recent study the Alaska State Housing Authority concluded that the new hospital would adequately meet Kodiak's needs for the next 15 to 20 years (Tryck, Nyman and Hayes 1968). All four doctors in Kodiak in 1973 were general practitioners, but one is also trained as a surgeon. In addition to these resident doctors, the hospital has the services of a third or fourth year medical student from the University of Washington on a rotation basis every six weeks. In October of 1973 the total hospital staff was 48 persons. The State runs a public health center in Kodiak with a program which includes immunizations, TB chest clinics, communicable and veneral disease clinics, mother and child good health clinics, and a school health program. One public health nurse serves the Kodiak urban area and another works in the outlying Kodiak villages on an intinerant basis (Kodiak Chamber of Commerce 1973). Alaska Natives receive care at the Kodiak hospital under a contract agreement with the U.S. Public Health Service. Private medical services in Kodiak are available through a small doctor's clinic which has a staff of four doctors, two dentists and one optometrist. The Coast Guard station maintains a 17 bed dispensary for lsister Claire Reedy, Administrator, Griffin Memorial Hospital, Kodiak October 1973. Personal communication. 2Ipid. 3Ipid. 4tpid. 480 military personnel and their dependents. The medical staff includes four physicians, three dentists and four nurses. Illness or injuries which require treatment beyond’ the capabilities of the dispensary are treated at the Elmendorf Air Force Base hospital in Anchorage or the Kodiak city hospital (U.S. Coast Guard 1973). Each of Kodiak's six outlying villages has a village health aide who has been trained by the Indian Health Service under a program run by the Alaska Native Federation. ‘Since no medical facilities have been built in the villages, the health aides operate out of their homes or the school. The health aides call the Kodiak hospital each night via a side ban radio communication system to report medical problems in the village and receive instructions. For cases requiring hospitalization or a doctor's care, patients generally are flown to Kodiak via commercial aircraft. In emergencies villagers can be evacuated by Coast Guard aircraft. Medical facilities and services in the Alaska Peninsula region are very limited as there is no hospital or physician in the area. Improved medical service is a major need in the area, especially in light of the high rate of serious accidents which occur on fishing boats and in the processing plants. At present, the best medical facility on the Alaska Peninsula is a health clinic in Sand Point run by. the Baptist General Conference. It is staffed by a registered nurse and is primarily an out-patient facility. The clinic includes a delivery room, space for emergency surgery, and two beds for patients awaiting evacuation to Anchorage or to Kodiak. The clinie serves Sand Point, neighboring villages and the transient’ fishing fleet (Alaska Consultants 1970). Another clinic staffed by a resident. nurse:is located in King Cove. It is funded jointly by the city and the local seafood processing plant (Alaska State Housing Authority 1968). The U. S. Public Health Service and the State provide health care to the region on an itinerant: basis. A state public health nurse visits most communities two or three times a year. U. S. Public Health Service doctors and dentists also hold clinics in the villages two or three times per year. For serious medical problems Alaska Peninsula residents generally are flown to Anchorage via scheduled air flights. In emergency the Coast Guard can evacuate persons to the Kodiak hospital (Alaska Consultants 1970). Utilities ‘ nee The City of Kodiak provides water for the urban area. The system had been improved but until very recently it had not been able to supply the huge quantities of water required by the fish processing industry. Isister Claire Reedy, Administrator, Griffin Memorial Hospital, Kodiak October 1973. Personal communication. 481 During periods when the local reservior was low, some of the processing plants had to shut down operations for several weeks at a time. As a result the reservior was expanded in the summer of 1973 and negotiations are currently underway to attract two more processing plants to Kodiak. The City of Kodiak also supplies the urban area with a sewer system; however, most homes in the outlying areas are served by septic tanks. A five million dollar plan is currently under way to expand the urban sewer services and build a sewage treatment facility. Port Lions, Ouzinkie, Old Harbor, and Akhiok have water and sewer systems which were built by the Public Health Service. Larsen Bay and Karluk do not have public utility systems for water or for sewer (Kodiak Island Borough 1973). The Kodiak urban area and Port Lions receive power from the Kodiak Electric Association; Ouzinkie has a city electric plant and Old Harbor is supplied power through the Alaska Village Electrical Cooperative Association. The U. S. Coast Guard Station and Chiniak Air Force Base have their own self-contained power systems (Kodiak Island Borough 1973). Electricity and water are supplied to the residents of Sand Point by one of the local processing plants. Sand Point has no community sewer system. Some of the homes are attached to a sewer line which discharges untreated sewage into a local slough. Others have lines which dispose untreated sewage into the sea. The community has regulations regarding the dumping of garbage but has no city operated garbage disposal system. Much of the city's refuse is simply dumped off the end of the dock. Cannery wastes are ground up before they are dumped into the sea (Alaska Consultants 1970). The City of King Cove operates a generating plant which supplies electricity to the residents of the community. Homes receive water from a line which serves the cannery; however, during the winter the line is sometimes frozen. King Cove has no sewage system. Homes with plumbing commonly have individual septic tanks. Those without plumbing rely on outhouses or "honey buckets." There is no refuse collection system in the community. Garbage is burned on the beaches where the remains will supposedly be taken out by the tide. However, much of the debris is carried through the community by strong winds. The canneries dump their processing wastes into the bay (Alaska State Housing Authority 1968). For the most part, residents of the eight small villages on the Alaska Peninsula do not have public utilities. Water is supplied by private wells or by local springs and streams. Sewage and garbage lJjack Ioadore, Kodiak City Manager, October 1973. Personal communication. 482 desposal is generally primitive. Chignik is the only village with a community power supply. In other villages individual homes are sometimes connected to small private generators, but mainly residents of these communities are without electric power (Federal Field Committee for Development Planning in Alaska 1971). Communications On Kodiak Island direct distance dialing telephone service is available in the Kodiak urban area, Port Lions, Chiniak Air Force Station and the Kodiak Coast Guard Base. All other communities rely on radios for communication, though RCA plans to extend "bush" radio telephone , service to all the Kodiak villages within the next few years (Kodiak Island Borough 1973). The Armed Forces Radio Service has maintained a radio station in Kodiak for 31 years. Today it broadcasts 24 hours per day. There is no commercial radio station in the area but there are two cable color television channels in Kodiak. A radio transceiver is based in the Kodiak Island Borough Hospital. The unit is used to extend medical assitance to the villages (Kodiak Island Borough 1973). In the Western Gulf of Alaska radio telephone is an important means of communication. Many boats in the fishing fleet have radio contact with their home canneries which creates a comprehensive radio network. In most of the smaller communities on the Alaska Peninsula the only communications facilities consist of two-way radios. On the Alaska ; Peninsula the only communities with telephone service are Sand Point and Cold Bay (Alaska Consultants 1970). INDUSTRIAL ACTIVITY Commercial Fishing and Fish Processing Fisheries, the mainstay of the Western Gulf economy, are partly based outside its defined geographic boundary. The salmon, shellfish, and part of the halibut caught on the north side of the Alaska Peninsula and in the Aleutian Islands region are processed in the Western Gulf of Alaska. Therefore, the fisheries data included in the following : discussion will encompass both the south and north side of the Alaska Peninsula, as well as the Aleutians and the Kodiak Island group. This area coincides with Alaska Department of Fish and Game management areas 9 through 13 (Figure 169) which include Kodiak, Chignik, South Peninsula, North Peninsula, and the Aleutians. : The U. S. commercial fisheries of the region are comprised of salmon, shellfish, and halibut, plus small amounts of. other fish. Salmon constituted the most important fishery up until the 1960s, but since that time the value of shellfish has exceeded the salmon value in most years. Halibut make up the third most important fishery. Rogers 60° 55° 165° REGION 160° 155° 150° 145° 140° 135° ALASKA 4 . CANADA BAY SOUTHEASTERN WESTERN) BRISTOL REGION "CENTRAL @ REGIONS: figure 169, REGION Southeastern Alaska - Pixon Entrance to Cape Such ling Central Alaska Cape Suckling te Scotch Cap, Unimak Island Western Alaska - The Aleutian IT lands west of Seotch Cap and the Bering Sea north through kotzebue Sound Ketchikan 6 - Prince Wm. Sound li - South Peninsula Petersburg-Wrargel | 7 - Resurrecticr Bay lf - Aleutian Islands Siths - Cook Inlet 15 - North Peninsula Juneau-Yakutat 9 - Kodiak 14 Bristol Bay Copper -Bering Rivers - chignik 1S Aretic-Yukon-kKuskokwii 155° 150° 145° 140° Areas and regions of the Alaska Departmert of Fish and Came “from Ataska Department of Virh and Game, various years). 135° 130° 130° 60° 50° cet 484 (1972) reports that in 1972 the value of the halibut landings from the international high-seas fleets equaled 29.3 percent of the total salmon value harvested in the region. Other fish harvested in the Western Gulf such as pollock, Pacific cod, Pacific ocean perch, and blackcod, while important to the fishing industries of the USSR and Japan, are not yet economically important to the economy of study region. Salmon Fishing! As is typical in Alaska, the salmon harvest of the Western Gulf of Alaska is highly cyclic. The 1960-1971 harvest data indicate alternating high and low catches for most years (Table 76). For this discussion, Kodiak and Chignik will be treated separately and the South and North Peninsula and the Aleutians will be discussed as a group (Aleutian- Peninsula). The Kodiak management area consists of nine districts where all five species of eastern Pacific salmon are harvested (Figure 170). The salmon fishery began in the area in 1882 and for 30 years red salmon was the principal species harvested. Since 1924, however, pink salmon have dominated the catch, and chum salmon have become the second most important species. Red salmon, which have declined drastically since the early years of the fishery, is now the third ranking species in the region. In the early years of the fishery, beach seines were the most common gear. Traps were introduced after 1920, and their use probably accounts for the increased catch. In later years, red salmon catches began to decline because of the intensive beach seining near the mouths of the major salmon-producing streams and poor fishing regulation. Regulations in the early years were fixed prior to the beginnng of the seasons and were not adjusted in accordance with the size of the runs. Under these regulations along some coastal areas, the salmon were subjected to continuous harvesting as they migrated. In recent years the fishery has been managed by district or groups of districts through the fixing of seasonal and weekly fishing periods for the various stocks of salmon. Trap gear was outlawed by state law in 1959, and the purse seine is now the most common type of gear in the region, followed by set gill nets which are used only in certain locations. When they run in sufficient numbers, red salmon are the first species harvested in the Kodiak area. This fishery usually begins in June and continues throughout the summer as red salmon are taken incidentally during the pink salmon fishery. Pink salmon become available in early June. At first these fish are generally caught near the capes; then, as the season progresses, the fish migrate into the bays. In recent times, most of the pinks have been caught on the even years. IMuch of the information concerning salmon fisheries was derived from the Governor's Study Group on Limited Entry, 1973. Table 76 COMMERCIAL SALMON CATCH BY AREA WESTERN GULF OF ALASKA 1960-1971 Total Western Gulf Region Kodiak Area Chignik Area Aleutian Peninsula* Area YEAR thousands oF Fish © thousands” ¥ subsvegion cusands sub-region © “thousands sub-region — 1960 14,283.6 8,456.3 59.2 1,069.0 7.5 4,758.3 33.3 1961 9,453.3 4,882.0 51.6 955.1 10.0 3,616.2 38.3 1962 23,588.8 15,750.1 66.8 2,249.4 9.5 5,589.3 23.7 1963 11,926.2 6,249.6 52.4 2,195.3 18.4 3,481.3 29.2 1964 20,768.7 13,713.8 66.0 2,578.3 12.4 4,476.6 21.6 1965 10,196.9 3,692.1 36.2 1,880.2 18.4 4,624.6 45.4 1966 15,095.7 12,217.9 80.9 1,160.2 7.7 1,717.6 11.4 1967 2,343.0 735.2 31.4 662.7 28.3 945.1 40.3 1968 16 353.3 10,337.5 63.2 2,395.9 14.7 3,619.9 22.1 1969 19 ,037.7 13,678.5 71.9 2,179.0 11.4 3,180.2 16.7 1970 22,556.8 13,939.2 61.8 3,094.7 13.7 5,522.9 24.5 1971 12,398.5 6,378.1 51.4 1,999.0 16.1 4,021.4 32.5 *Includes South Peninsula, North Peninsula and Aleutian ‘slancs. Source: Rogers 1972. S8P "KODIAK AREA Figure 170. Alaska Department of Fish and Game areas and subareas in the Western Gulf of Alaska. 980 487 During the odd years regulations are more strict since there are fewer streams producing fish. The fishery is regulated by fixing of weekly fishing periods. When this proves inadequate and not enough fish return to the streams, districts are closed by emergency orders until it is certain that enough spawners will eventually return. The pink salmon usually peak during the last week of July through the first week of August; however, some variations do occur. More than 10 percent of the pink salmon run can be harvested during a single day's fishing due to the recent increases in the amount of gear in the fishery. Chum and silver salmon are usually harvested after the pink fishery by purse seines. The few king salmon taken are harvested incidentally during the pink fishery. The Kodiak area accounts for most of the salmon caught in the Western Gulf (Table 76 ). With two exceptions (1965 and 1967) the Kodiak subregion accounted for more than half of the catch from 1960 through 1971. The Chignik management area (Figure 170) is located on the south side of the Alaska Peninsula and extends 160 km. east and west of Chignik Bay. Salmon harvesting on the Chignik area began in 1888 and for many years was confined to a very small area within a few kilmeters of the Chignik River. The principal species, red salmon, was generally part of the catch. Traps operated in the area until 1954. Salmon are now harvested exclusively by purse seines or hand purse seines. Two red salmon runs enter the Chignik River system. The early run enters Chignik Lagoon in early June and peaks toward the end of June. The late run enters the lagoon late in June and peaks about the middle of July. Most Chignik red salmon are caught in the Chignik Lagoon. A significant portion of the catch is now harvested east of Chignik Bay near Cape Kumlik and in the vicinity of Cape Igvak. The red salmon fishery is regulated with the aid of daily weir counts and catch statistics. Weekly fishing periods are adjusted according to the strength of returning runs. Only short hand seines are used to take salmon in the Chignik Bay district and these are mainly in the shallow Chignik Lagoon. Coho salmon are taken within Chignik Lagoon in late summer after the red salmon run. King salmon are also taken in small numbers during the red salmon harvest. Pink and chum salmon are the predominant species taken in the other districts within the Chignik area. Most harvesting of these species takes place after the red salmon run in the Chignik Bay district has tapered off. Unlike the fishing at Chignik Bay, longer seines are used in these districts for harvesting pink and chum salmon. The fish are harvested by an annual average of 75 seine boats. The largest pink and chum harvests in the area have occurred within the past decade. This growth of the harvests is attributed to fishing regulations which have set fixed fishery periods and have closed areas when necessary to permit adequate escapements. The Chignik area accounted for an annual average of 15 percent of the Western Gulf's salmon catch from 1960 to 1971. The Aleutian-Peninsula area consists of the south and north sides of the Alaska Peninsula and the Aleutian Islands. The south peninsula area (Figure 170) lies between Unimak Pass and Samalga Pass. Salmon 488 fishing in this area began near Cold Bay and Stepovak Bay in 1908. Gradually, harvesting activities spread to the False Pass area and then to the Shumagin Islands. In 1918 red salmon was the major species taken in all areas except the Shumigan Islands where pink salmon predominated. Beach seines were the most common gear in the early years, with traps becoming numerous after 1917. Fishing begins in June in the Ikatan-Morzhovoi Bay vicinity and on the south side of Unimak Island. The fish harvested are red salmon bound for Bristol Bay and chums bound for nearby districts and western Alaska. Near Popof Head in the Shumagin Islands, red salmon bound for Bristol Bay and chums bound for the Alaska Peninsula streams are harvested in June. The south Unimak fishery employs drift gill nets and purse seines; the Shumagin fishery utilizes seines and gill nets. When the red chum runs decline, the Unimak fishery seiners begin havresting pink salmon in the Shumagin Islands, Pavlof Bay, and Cold Bay. Fishing began in the north peninsula area in 1906 at Nelson Lagoon where red salmon were taken by gill nets. In 1912 the harvest of red salmon began at Port Moller, utilizing purse seines. Red salmon catches on the north peninsula peaked in 1921 and recent catches have approached only 20 to 25 percent of the peak catch. Chum salmon has been and is the second most important species in the area. Fishing gear utilized in the north Alaska Peninsula area includes set gill nets, drift gill nets, and some purse seines. Harvesting begins in the area between Nelson Lagoon and Ilnik in June after the south Unimak fishery has begun and continues in the Bear River and Nelson Lagoon areas until late August and early September respectively. The salmon fishery in the Aleutian Islands area (Figure 170) occurs almost entirely in the bays of Unalaska Island. Most of the catch is taken after the completion of the June fishing in the south Unimak area. The harvesting is done with purse seines. Pink salmon is the principal species harvested. Fisheries management in the area is often hampered by adverse weather and long distances. Catch statistics for the Aleutian-Peninsula area can been seen in Table 76. This area accounted for an annual average of 30 percent of the total salmon catch of the Western Gulf of Alaska from 1960 through 1971. Most of the salmon harvested in the Western Gulf of Alaska is canned, although small amounts are sold fresh, frozen, or cured. Since the early 1960s a market for salmon roe has been increasing. The total salmon roe production increased from approximately 34.7 metric tons in 1962 to 1,315 metric tons in 1971 (Governor's Study Group on Limited Entry 1973). In the Western Gulf of Alaska area, 20 plants processed salmon in 1972. Table 77 indicates the types of salmon products processed in each plant. The majority of these plants produced either canned or frozen salmon or salmon eggs; however, one plant produced smoked fish, and four of the plants produced salted fish. 489 Table 77 ALASKA SALMON PROCESSORS - 1972 WESTERN GULF OF ALASKA SALMON _ PRODUCTS 2 8 8 8 g & 8 ” . g ° ° q ok Operator Location & cz 5 OS ee Alaska Ice and Storage, Inc. Kodiak x Alaska Packers Association Larsen Bay x x Chignik x x B and B_ Fisheries Kodiak x x x C and C Fisheries Pleasant Harbor x x Columbia Wards Fisheries Port Bailey xX ; Alitak x x x King Crab, Inc. Kodiak x x x Borge Larsen False Pass x Marubeni America Corp. Kodiak x Middle Bay Fisheries Kodiak x x New England Fish Co. Uganik Bay x x x Peter Pan Seafoods False Pass x x x King Cove x x x Queen Fisheries Kodiak x x Western Alaska Enterprises, Inc. False Pass x Kodiak x Larsen Bay x Whitney-Fidalgo Seafoods, Inc. Uyak x x Kodiak x x Source: Alaska Department of Fish and Game 1973a. 490 Shellfish King Crab: Presently the most productive king crab areas in the Western Gulf of Alaska are in the Kodiak Island, Aleutian and Bering Sea areas (Table 78). During the mid-1960s the Kodiak area was the largest producer, but from 1966 to 1971, king crab production in Kodiak declined from 41,000 metric tons to 5,300 metric tons. Since 1967 the Aleutian Islands-Bering Sea area has been the most productive, with nearly three-fourths of the entire catch of the Western Gulf. Eldridge (1972) describes the patterns and trends of the king crab fishery as follows: Before one can adequately understand the changes which have taken place in the level of landings during the development of the king crab resource, one must be aware of the technological and economic factors which influenced that development. One of the most important factors is the nature of the produce itself and how it was marketed. In short, until the early and mid-1960s, the demand and the technological capability of the fishing fleet, not the abundance of the king crabs, regulated the catches of king crab. In other words, the peak catches of king crab occurred in the mid- 1960s because it was not possible until that time to (1) catch and process large quantitites of king crab, and, more importantly, (2) to sell the king crab once it has been processed. At the present time, landings more nearly reflect the relative abundance of king crab because the demand is sufficient to absorb any amount of king crab that can be caught. Another important trend in the development of the fishery was the change in size and efficiency of vessels. Initially, the fishery was dominated by small, relatively inefficient vessels. Although many of these vessels are still in the fishery, they have been replaced in large part by more efficient larger vessels. The entry of large vessels led to a drastic change in the location and time of fishing for king crabs. For instance, in 1960 in the northeast fishing dis- trict of Kodiak, approximately 90 percent of the catch occurred in the inshore grounds; whereas since 1965 only about 20 percent of the catch has been taken there. In addition, the fishery has changed from primarily a winter to a summer and fall one. 491 Table 78 KING CRAB CATCH - WESTERN GULF OF ALASKA 1965-1971 (Thousands of Pounds) Year Kodiak Chignik So. Peninsula Aleutians-Bering Sea 1971 11,820.0 13.3 4,211.8 49,785.2 1970 12,069.5— 22.8 3,512.2 31,896.1 1969 12,724.1 310.1 4,335.3 35,559.8 1968 22,117.6 341.7 10,949.0 42,120.0 1967 62,864.4 247.7 : 17,180.0 44,810.0 1966 90,726.2 561.3 22,519.9 41,473.2 1965 76 ,837.9 769.9 14,407.0 36,296.0 Source: Alaska Department of Fish and Game, various years. 492 The fishing strategy also changed with the develop- ment of the fishery. Formerly, fishermen preferred to fish for the larger crabs in the more accessible fishing grounds. An example of this is the early fishery for king crabs in Chiniak Bay which is quite close to the town of Kodiak. At the present time, they fish all available grounds and keep all legal crabs. Furthermore, the total catch is regulated primarily by quotas imposed by the Alaska Department of Fish and Game rather than the level of demand for king crab meat. Current prices paid to king crab fishermen are high. In the Kodiak area the 1973 price went as high as 1.57 dollars per kg., as compared to the 1972 rate of 86 cents per kg. During. the 1973 season eight processor ships operated in the Kodiak area, and it is estimated that these ships accounted for 40 to 50 percent of the total amount of crab processed. 2 Dungeness Crab:3 The amount of Dungeness crab caught in the various areas of the Western Gulf is shown in Table 79. Kodiak is by far the most productive area for this species. Much of this crab is found in the bays on the southwest corner of Kodiak Island. Dungeness crabs comprise an inshore fishery with most found between two and 20 fathoms. They range much closer to shore than the king crab, which is usually caught at depths up to 150 fathoms. Because the Dungeness crab is an inshore species, smaller vessels, cheaper gear, and small pots can be used. Dungeness landings in Alaska fell from 6,000 metric tons in 1968 to 1,700 metric tons in 1971 (Alaska Department of Economic Development 1972). Supplies were so low that wholesale price quotations were rarely given. The price to fishermen was reported to be 40 cents per kg. in January 1972 and by the end of the year had nearly doubled to 75 cents per kg. (Alaska Department of Economic Development 1973). Tanner Crab: Tanner crab harvests have been steadily increasing since 1967 when catch statistics were first recorded (Table 80). Most tanner crab are caught in the Kodiak area where the 1971 catch amounted to 3,400 metric tons. In that same year the South Peninsula area recorded a catch of 950 metric tons. Although figures are not yet available, it is expected that tanner crab landings at Kodiak in 1972 exceeded 4,500 metric tons (Alaska Department of Economic Development 1973b). Kodiak fishermen received 26 cents per kg. for this species during 1973 (Alaska Department of Economic Development 1973c). lkodiak Mirror, September 10, 1973. 2tpid. . 3Much of the information in this section is derived from Wolf Management Service 1965. 493 Table 79 DUNGENESS CRAB CATCH - WESTERN GULF OF ALASKA - 1965-1971 (Thousands of Pounds) Year Kodiak Chignik So. Peninsula Aleutians - Bering Sea 1971 1,445.9 5.9 5.9 16.2 1970 5,741.4 - 5.4 711.9 1969 5,813.7 305.6 750.7 629.1 1968 6,829.1 - 953.4 - 1967 6,663.7 - - - 1966 1,416.3 - - 26.4 1965 3,331.6 - 16.8 - Source : Alaska Department of Fish and Game, various years. Year 1971 1970 1969 1968 1967 Source: ey olds! ivel-coul ~ Adehik AW Uo fA8Te aid a : Table 80 - TANNER CRAB CATCH - WESTERN GULF OF ALASKA a2 £11967419710° Ate ic (Thousands of Pounds) Kodiak Chignik ©.2 So. Peninsula 7,410:8 152.300 be 2,140.8 7, 70822 2.8 r 2,093.6 6,822.7 38.1 bree 606.3 2,560.7 21.6 110.6 11:0 1.6 3.1 2.01 Alaska ,Department of Fish and Game, various years. .2169¥ auvonsv ,emse) bis deri 10 Insinnsue Aleutians 21.0 12.8 494 495 Shrimp: Most shrimp caught in Alaska are harvested in the Western Gulf. The region's shrimp fishing grounds are shown on Figure 96. Most of the catch is taken in the Kodiak area, where in 1971 approximately 37,200 of the region's 40,100 metric tons of shrimp were harvested (Table 81). The 1972 shrimp catch in the Kodiak area was estimated to be 26,800 metric tons, a reduction of 10,400 metric tons from the 1971 harvest. The reduction partially resulted from the Alaska Department of Fish and Game's efforts to reduce the harvest by eliminating the carryover concept in quarterly shrimp quotas. Prior to May 22, 1972 any portion of the quota not harvested during one quarter was carried over to the following quarter (Alaska Department of Fish and Game 1973b). The harvest was also reduced by a water shortage which drastically curtailed shrimp processing operations in Kodiak from late January through April 1972. In addition, the Shrimp Trawlers Association went out on strike from March through May. The strikers sought a price increase for delivered shrimp and settled for 12.1 cents per kg., 2.75 cents more than the pre-strike price (Alaska Department of Fish and Game 1973b). For 1972 as a whole, the average ex-vessel price for raw, whole shrimp in Kodiak was 11.6 cents per kg. (Alaska Department of Fish and Game 1973c). However, because of deductions made by processors for trash fish and debris contained in gross deliveries, this is somewhat higher than the fishermen actually received. Other Shellfish: Razor clams and scallops are also taken in the Western Gulf of Alaska. Virtually all scallops are taken at Kodiak which averaged a harvest of approximately 450 metric tons annually betweeen 168 and 1971 (Alaska Department of Fish and Game, various years). Most of the clams dug in the Western Gulf of Alaska are also harvested in the Kodiak area. The clam harvest increased from one metric ton in 1967 to 86 metric tons in 1971 (Alaska Department of Fish and Game, various years). Shellfish Processors: There were 24 shellfish processors listed in the Western Gulf of Alaska for 1972. These produce: fresh, frozen, and canned crab meat and shrimp, fresh and frozen scallops; and frozen, canned and fresh (bait) razor clams. Twelve of these plants are located in the city of Kodiak--six on other parts of Kodiak Island, and the remaining six on the south side of the Alaska Peninsula (Alaska Department of Fish and Game 1973a). Halibut! Halibut harvests in Alaska coastal waters are closely regulated by the International Pacific Halibut Commission. From 1960 to 1970 landings lyuch of the information in this section was dervied from International Pacific Halibut Commission 1973. Year 1971 1970 1969 1968 1967 1966 1965 Source: Table 81 SHRIMP CATCH .- WESTERN GULF OF ALASKA 1965-1971 (Thousands of Pounds) Kodiak Chignik So. Peninsula 82,153.7 1,091.7 5,228.2 62,181.2 890.7 4,399.0 41,243.5 419.9 2,657.0 34,361.6 1,153.7 4,373.9 38,267.9 - - 24,097.7 - - 13,810.2 - - Alaska Department of Fish and Game, various years. 496 497 e@ of halibut remained fairly stable at 22,700 to 27,200 metric tons annually. After the 1971 season, research results became available which indicated that the stock of halibut was being seriously depleted and quotas would have to be reduced. As a result of lower quotas, the price of halibut doubled from 66 cents per kg. in 1971 to approximately 1.32 dollars per kg. in 1972. The rise in price, combined with recent salmon runs, induced more vessels to enter the halibut fishery. The port of Kodiak is the major landing point in Alaska for the halibut catch. In 1972 nearly 4,100 metric tons of halibut were landed in Kodiak out of a total Alaska catch of 10,700 metric tons. The landings in Kodiak have generally increased in recent years despite the reduction in the halibut quotas. More vessels are electing to land their catches in Kodiak rather than Prince Rupert, Seattle, or other southern ports because the prices being paid at Kodiak have increased relative to the prices at the other ports. Sand Point is the other major halibut port in the Western Gulf region. Until 1972 landings at Sand Point had been declining since they peaked at 1,700 metric tons in 1966. In 1971 only 320 metric tons of halibut were landed at Sand Point. These landings, however, rose to 470 metric tons in 1972. Herring Fishery Most herring caught in the Western Gulf of Alaska are taken from the Kodiak area. The 1971 and 1972 Kodiak catches were 568,000 and 195 metric tons, respectively (Alaska Department of Fish and Game 1973b). During the summer of 1972 an additional 48 metric tons of herring were harvested for sale to the halibut boats for bait. Subsistence Fisheries Although quite widespread, subsistence fishing is not as important in the Western Gulf of Alaska as it is in some other areas of the state. The regional supervisor for commercial fisheries in the Kodiak area reports the following subsistence figures for the past 10 years (1963- 1972) :1 Subsistence Fish Area er year Kodiak 14,000-20,000 Chignik 5,500 AK Peninsula- Aleutians 5,000 ljack Lechmer, Regional Supervision, Alaska Department of Fish and Game, Commercial Fisheries Division, Kodiak, October 1973. Personal communi- cation. 498 Value of Catch In 1970 the value of the salmon catch to fishermen amounted to approximately 15.7 million dollars (Table 82). In that same year, fishermen earned a total of 18.1 million dollars for the shellfish catch and 3.5 million dollars for the catch of other species (halibut, herring, and bottom fish). The total value to fishermen of all fish products from the Western Gulf in 1970 amounted to approximately 37.3 million dollars. In 1970 the wholesale value to processors totaled 41.5 million dollars for salmon, 38.5 million dollars for shellfish, and 4.5 million dollars for other fish (Table 83). The comparison of the raw fish value to wholesale values indicates the value added by processing. The proportion of value added in processing for all salmon products amounted to 62 percent of total wholesale value in 1970. For shellfish and other fish the value added in processing was 53 percent and 23 percent respectively in 1970. The data in Table 84 show how the proportion of value added in processing has changed over time relative to the value added by fishermen. In the years for which data are available, the share of value added attributable to processing has remained remarkabley constant in the salmon industry. On the average, about two-thirds of the wholesale value of salmon is due to processing and one-third is value added by fishermen. In sharp constrast to this, the share of value added by fishermen has reached nearly 60 percent of total value in the king crab industry. As the catch of king crab has declined and the price has more than doubled, the fishermen's share of value added has increased markedly. Both the price and the share of value added have moved quite erratically in the shrimp industry. If anything, the processors seem to have gained a somewhat larger share of value added as the price of shrimp has risen in recent years. External Factors Affecting Fisheries Oil Pollution:! During February and March 1970, oil was found in the coastal waters and on the shores of Kodiak Island. It was estimated that at least 1,600 km. of coastline along the eastern side of Kodiak Island group, Alaska Peninsula, Kenai Peninsula, and Montague Island in Prince William Sound were affected by oil. 01d Afognak was the only area where oil was found in large quantities; oil on kelp was estiamted at 18 kg. per 30 m. for 2.4 km. surveyed. In other areas, small concentrations of oil were found on birds, sea mammals, beaches, and debris. A joint investigation by the Federal Water Quality Administration and the State of Alaska concluded that the most likely source of. the oil was tankships which dumped ballast waters and "slop" oils at sea as they entered Cook Inlet to pick up crude oil. lMuch of the information for this section was derived from Federal Water Quality Administration 1970. : Table 82 QOMMERCIAL CATCH AND VALUE TO FISHERMEN WESTERN GULF OF ALASKA - 1960-1971 SHELLFISH VALUE SALMON OTHER FISH® SHELLFISH “as percent of Year Pounds ~~~~*Vadlue Poun| alue Pounds ~—~—~—~~—~Vailue SALMON VALUE 1960 68,413,676 $ 6,981,304 57,600 nea. 27,818,268 $ 2,012,525 28.8% 1961 43,333,428 5,107,366 - - 46,032,354 3,551,884 69.5 1962 84,842,568 11,583,229 - - 58,655,575 5,038,748 43.5 1963 46,751,004 5,763,453 - - 81,696,787 6,049,795 105.0 1964 83,887,121 8,862,267 619,550 nea 87,566,140 6,598,043 74.5 1965 44,085,000 5,497,988 1, 482,095 nea 145,469, 400 13,365,875 243.1 1966 68, 366,127 9,095,851 6, 266 580 nea 180,834,700 18,774,022 206.4 1967 14,760,994> 2,310,522 5,157,395 nea 169,007,100 16,813,824 727.7 1968 68,836,779 9,888,957 3,983,708 nea 126 ,631,900 19,933,433 201.6 1969 87,089,240 12,101,053 2,273,945 $ 61,173 114,382,598 18,873,679 156.0 1970 102,219,503 15,742,936 11,218,944 3,473,179? 134,249,063 18,141,886 115.2 1971 64,616,970 10,387,206 10,599,117 3,106,349 166,684,050 23,372,309 225.0 n. 4 Halibut included in 1970 and 1971, not reported for earlier years. > Kodiak 1967 catch only one-tenth 1948-1970 annual average a. - Data not available Source: Rogers 1972. 560 500 Table 83 FISH PRODUCTS AND WHOLESALE VALUE BY SPECIES AND TYPE OF PRODUCT WESTERN GULF OF ALASKA - 1970 Pounds Prepared Wholesale Value Wholesale Value for Market to Processor per Pound SALMON Fresh : 397,908 $ 100,225 $ .25 Frozen 2,851,424 1,177,851 41 Cured 55,950 39,190 .70 Canned 53,116,944 35,988,884 .68 Roe 3,442,120 4,215,114 1.22 TOTAL SALMON 59, 864,346 $41,521, 264 3 .69 OTHER FISII Halibut 8,712,988 4,356,491 -50 Herring 152,235 147,773 97 Herring eggs or kelp - - - Bottom Fish 53,149 3,298 .06 Other 26,727 2,695 .10 TOTAL OTHER FISH ~8,045-14 js 27 5.50 SHELLFISH King Crab 11,476,763 20,281,672 1.77 Dungeness 4,386,530 2,048,392 -47 Tanner Crab 2,240,417 2,443,957 1.09 Shrimp 10,306,294 12,830,446 1.24 Clams 217,355 60,811 -28 Scallops 748,284 863,676 1.15 TOTAL SHELLFISH 25,375,643 7 $38,528,954 7 3I.3T TOTAL ALL PRODUCTS 98,185,133 $84,560,478 $ .86 a Cured salmon other than roe Source: Rogers 1972. Table 84 SHARES OF VALUE ADDED IN SELECTED FISHERIES PRODUCTS 1965-1971 Pounds Wholesale Value to Percent of Percent of Processed Value per Fishermen per Value Value (Millions Processed Processed Added by Added by Year of pounds) Pound Pound Processing Fishermen SALMON PRODUCT S@& 1965 31.5 66.2 17.5 74 26 1966 47.2 59.6 19.3 68 32 1967 na. na. na. na. nea. 1968 45.1 66.8 22.0 67 33 1969 nea. n.a. na. na. nea. 1970 59.9 69.4 26.3 62 38 1971 46.8 75.3 22.2 71 29 KING CRAB 1965 34.0 93.1 37.4 60 40 1966 46.1 96.3 34.0 65 35 1967 29.9 123.6 50.1 59 41 1968 19.3 219.8 113.1 49 51 1969 12.8 207.3 115.5 44 56 1970 14.8 167.3 88.9 47 53 1971 17.1 188.7 111.3 41 59 SHRIMP 1965 2.6 70.7 28.4 60 40 1966 3.3 99.6 38.4 61 39 1967 8.8 88.3 19.3 78 22 1968 5.7 124.7 40.6 67 33 1969 8.1 98.5 20.2 79 21 1970 11.4 124.1 26.0 79 21 1971 14.9 106.0 26.3 75 25 @Data pertains to the Western Gulf of Alaska region and was taken from Governor's Study Group on Limited Entry 1973 and Rogers 1972. bData is not available specifically for the Western Gulf of Alaska; therefore, data pertaining to Lhe entice stale was utilized (Alaska Department of Economic Development 1972). Since most of the king crab and shrimp taken in the state are harvested in the Western Gulf it was felt that relevant value-added statistics could be obtained using statewide information. 501 502 The damage caused to the fisheries by this particular spill was minimal, probably because of low oil concentrations. However, the potential exists for extensive damage. In another incident several months prior to the February-March 1970 episode, one fisherman reported that he had to discard an entire catch of 4.5 metric tons of shrimp because oil fouled his catch. Oil could also damage large amount of fishing gear and crab floats and lines. This happened to a limited extent during the February-March 1972 oil incident. Fisheries Waste Processing! Processing plants in Kodiak have traditionally dumped their seafood wastes back into the bay and relied on the winds and tides to disperse _and recycle the debris. The amount of waste varies with the method of processing and the species involved. Processing waste for king crab, when frozen in the shell, is only bout 18 percent of harvested weight. By comparison, waste for shelled crab is over 60 percent. The highest levels of waste, 80 to 84 percent, occur in canned shrimp processing. Thus, the Kodiak area's 1971 harvest of 37,200 metric tons of shrimp, resulted in an estimated 29,500 metric tons of waste being dumped into the surrounding waters. The concentration of 14 processing plants in the city of Kodiak has created a pollution problem which has come under attack by the U. S. Environmental Protection Agency. The agency announced that after April 1, 1973 the city's plants could no longer dispose of their processing wastes by dumping them into the bay. The EPA regulation provided the opportunity for a private firm, Bio-Dry, Inc., to build a one million dollar plant in Kodiak to process the seafood wastes. The facility, the first of its kind in the United States, produces a high- quality protein meal which is used as a supplement to animal food. In order for Bio-Dry to process their wastes, the seafood plants must build large hoppers which can hold at least eight hours of strained processing wastes. The material from the hoppers is dumped into trucks and transported to the Bio-Dry plant for processing. The net cost or net payment for processing wastes is dependent upon the market price of crude protein. Contracts between Bio-Dry and the seafood processors stipulate that Bio-Dry will pay for the wastes if the price of protein is above a certain level; if the price falls below that threshold, however, the processing plants have agreed to pay Bio-Dry for the service. lyon Egelus, Manager, Kodiak Bio-Dry Plant, October 1973. Personal communication. 503 By October 1973 only six of Kodiak's processing plants were using the Bio-Dry facility. EPA has extended the deadline for compliance with the regulation to allow the other plants to install the necessary equipment. Until these plants provide the Bio-Dry plant with their wastes, it will continue to operate far below capacity. The manager of Bio-Dry indicated that his firm planned to install equipment to handle fish processing wastes, but would not do so until enough seafood plants are tied in to justify the additional expenditure. Foreign Fisheries Table 85 shows the extent to which other nations harvest fish resources of the Western Gulf region. Except for shrimp and halibut, little foreign competition exists for those fish species currently of economic value to Western Gulf fishermen. The Soviet Union and Japan harvested 33 percent and seven percent, respectively, of the region's shrimp catch between 1916 and 1969. Approximately 30 percent of the halibut taken in the region between 1905 and 1969 were taken by Canadian fishermen, but much of the Canadian catch is generally landed at either Kodiak or Sand Point for processing. The demersal or ocean bottom fishery (excluding halibut) of the Western Gulf has been utilized almost solely by foreign fishermen. Japanese fishermen harvest virtually all of the pollock, Pacific cod, blackcod, and flatfish. Soviet and Japanese fishermen each take about half of the Pacific Ocean perch. As the stocks of fish currently being harvested by U.S. fishermen decline, the demersal fishery will become increasingly important to U.S. fishermen, and foreign competition will become a more important factor in the fisheries economy of the Western Gulf. Agriculture Agriculture is a small segment of the economy of the Western Gulf of Alaska. There are no commercial vegetables or feed crops produced. Native grasses are harvested on only 61 hectares (Alaska Crop and Livestock Reporting Service 1973). The mainstay of the agricultural sector is beef cattle production. In 1971 there were approximately 4,500 beef cattle, 105 sheep and a few horses in the region (Table 86). These animals utilized nearly 158,000 hectares of grazing land under lease from the federal and state governments. Figure 171 shows the principal grazing areas of the Western Gulf. The beef industry is still underdeveloped. It operates under several handicaps which account for its slow growth rate. Stephens (1973) has summarized these handicaps as follows: .+.The Alaskan beef producer, unlike his counter- part in other states, must raise his cattle from calves to full-grown steers, slaughter and market them by himself. There are limited-service Table 85 FOREIGN FISHERIES INVOLVEMENT IN THE WESTERN GULF OF ALASKA Total Year of First Historic Catch* Species Recorded Catch (millions of pounds) National Distribution of Catch 504 (Approx. Percentage) Shrimp 1916 307.9 Tanner Crab 1964 10.3 King Crab 1930 588.5 Herring 1907 1154.0 Salmon Pink 1905 1841.6 Coho 1905 85.7 King 1905 11.2 Chum 1905 732.6 Red 1905 1830.9 Pollock 1933 81.12 Pacific Cod 1905 14,6bs¢ Pacific Ocean Perch 1956 703.44 Blackcod 1913 38.14 Halibut 1905 1538. 3° Flatfish 1933 52.4 (excluding halibut) Also includes Cook Inlet and a portion of Prince Willian Sound bAlso includes Cook Inlet, Prince William Sound and Yakutat ©1956-69 only *From first record to 1969 in Western Gulf of Alaska Source: Buck 1973. U.S.A. - 60 U.S.S.R. - 33 Japan - 4 U.S.A. - 100 U.S.A. - 99 U.S.S.R. - 1 U.S.A. - 100 U.S.A. - 100 U.S.A. - 100 U.S.A. - 100 U.S.A. - 100 U.S.A. - 100 Japan - 100 Japan - 100 Japan - 56 U.S.S.R. - 44 Japan - 99 U.S.A. - 1 U.S.A. - = 70 Canada - 30 Japan - 100 505 Table 86 FEDERAL AND STATE GRAZING LEASES WESTERN GULF OF ALASKA - 1971 Authorized ANNUAL RENTAL Stocking Rate Livestock on Lease Area Acreage Issued Expiration (AU. Cattle Sheep Tlorses Chirikof Island 31,067 $600.0 1/1/56 12/31/76 1,000 598 s Kodiak-MididTe Bay 21,650 3120.00 12/11/71 12/31/97 200 174 - 10 Kodiak (An‘one-Larsen Bay) 24, 400 $115.70 1/1/57 12/31/76 208 107 = 21 Narventer ind Bear Islands T30 > 25.00 1/1/64 12/31/83 30 14 - : Kodiak-Nar=ow Cape 21,005 $390.00 5/1/70 4/30/95 650 S60 7 6 Kodiak = Ugak Bay 9,540 ¥ 36.00 11/1/71 __ 12/31/95 60 66 = = Kodiak - Saltery Cove 35,557 $165.00 1/1/71 12/31/2001 275 155 = = Sitkinak TsTand 84,200 3900.00 (Lessee’s Estimate) 1/1/60 12/31/79 1500 915 - - Spruce Island 3,600 3 50.00 - 1/1/59 12/31/78 75 ll = = Kodiak-Ugaiitk Bay 6,000 Free Use 1/1/55 12/21/74 40 Goats 17 Sheep s Sitkelidak TsTand 74, 700 $580.00 1/1/60 12/31/79 850 781 SS 28 Sitkink Tsiand 17,000 $240.00 1/1/60 12/31/74 400 80 50 2 Kodiak-Passagshak Bay 25,040 $265.00 8/1/70 7/31/95 440 386 : 4 Sanak TsTand 10,100 ~ $150.00 1/1/63 12/31/82 250 161 = = Woenesenski Island 7,500 $ 45.00 1/1/60 12/31/79 75 69 - - Simeonof Island 10,850 $165.00 1/1/61 12/31/80 275 273 7 7 Chermabvea Island 7, 248 $120.00 . 1/1/64 12/31/83 200 woo - _- TOTALS 389, 887 6,528 4,472 105 _80 | | (1) An animal unit (A.U.) is considered to be the equivalert of one cow, five sheep or one horse over six months of age. Source: U.S. Department of the Interior, Bureau of Land Management, land status computer printouts of the Aleut, Bristol Bay and Koniag Regional Native Corporations, July 1973. sr 1e6° 164° Qe 160° ise° Figure 171. Existing land use EXPLORATORY OIL WELL + FEDERAL OR-STATE GRAZING LEASE RE UN FEDERAL OR STATE OIL & GAS LEASE PROPOSED TIMBER SALE EXISTING TIMBER SALE WINTER SUBSISTENCE BOUNDRY SUMMER SUBSISTENCE BOUNDRY = = -—-~—--- ise° 1sae 1s2° 507 industries such as feed and equipment dealers and no feedlot operators. He does not have an organized market in which to sell his product. He does not have a banking system that is familiar with his industry. Much of the land on which he grazes his stock is leased from the state or federal government. This has tended to discourage the ranchers' willingness to make capital improvements on such lands. Currently some of this land is under consideration for selection by Native villages as part of the Native Land Claims Act. This has limited development on those lands until the land selections are made. The characteristics of beef raising per se, create other problems. Beef cattle require large areas of land for grazing. The only areas in the state suit able for grazing throughout the year are in southern coastal districts. The most suitable areas in terms of climate and vegetation, Kodiak Island and adjacent islands on Aleutian Chain, are remote. This causes significant increases in transportation costs of the various production inputs, especially grain. Heifers cannot be bred until they are two years old and have a nine-month gestation period. Beef cattle in Alaska are usually not slaughtered until they are two-and-a- half years old. The capital required to begin and main- tain production must therefore be inveted for an extended period of time. This tends to increase working capital requirements and venture risk. Alaskan beef cannot at this time be produced at a competitive price and equal quality as the beef being shipped into the state. The vast majority of fabricated beef sold in the retail trade in Alaska is USDA Choice Grade. The significant aspect of Choice Grade for this discussion is the degree of marbling in the meat (flecks of fat) required. Choice grade is achieved by taking the animal off grass and intensively feeding it grain before slaughter. This is usually done in other states by "feedlot operators" who specialize in "finishing off" or bringing the animal "up to grade."" In Alaska the transportation cost of grain to beef production areas, (either im- ported or locally grown), is too expensive to permit this final fattening process before slaughter. Con- sequently, Alaskan beef is primarily grass-fed and at best could be graded as USDA Good, one grade below Choice. Brown bear predation is another problem faced by beef cattle producers, particularly on Kodiak Island. According to the U.S. Bureau of Sport Fisheries and Wildlife (1972, Kodiak ranchers have reported that, on the average, 47 head of cattle are lost to brown bear predation annually. 508 Beef and veal production in-the Western Gulf area averaged 132 metric tons yearly from 1965 through 1972 with an average yearly value of 140 thousand dollars (Alaska Crop and Livestock Reporting Service 1973). During 1970 production amounted to 151 metric tons and was valued at 161 thousand dollars in 1971, 91 metric tons valued at 107 thousand dollars were produced and in 1972 production amounted to 121 metric tons and was valued at 150 thousand dollars (Alaska Crop and Livestock Reporting Service 1973). Most of the beef produced on Kodiak Island is processed at a cooperative slaughterhouse near the town of Kodiak. Three hundred head were processed at the slaughterhouse in 1972.1 The beef is primarily sold as locker beef with a small portion being sold as manufactured beef. The cattle on the islands south of the Alaska Peninsula receive very little management. Many herds have run wild for years and have a high proportion of bulls. Until recently only a few of these animals have been slaughtered, and these were for local consumption only. During the summer of 1973, 100 head of cattle were barged from Sanak Island to Kodiak for slaughtering.2 Additional cattle from the south peninsula area will probably be processed at the Kodiak slaughter facility. Reindeer were once grazed on Kodiak Island and the Alaska Peninsula. In July 1933, a permit was issued to the Alitak Native Reindeer Company by the U.S. General Land Office for grazing 20,000 reindeer on 259,000 hectares, but this lease expired in 1953 (U.S. Bureau of Sport Fisheries and Wildlife 1972). In 1968 it was reported that there were still 600 reindeer on Kodiak Island, but very few animals were being harvested (Federal Field Committee for Development Planning in Alaska 1968). These animals are not herded but roam at will in the southwest portion of Kodiak Island, mostly north of Olga Bay. It is estimated that approximately 50 animals are killed yearly for local consumption. 3 Forestry Little timber harvesting takes place in the Western Gulf of Alaska, although the U. S. Forest Service (1973) estimates that Kodiak, Afognak, and the Shuyak Island group could supply between 40 to 50 million board feet per year on a sustained-yield basis. Currently the only active operation is on the southern end of Afognak Island (Figure 171). The annual cut is small, approximately one million board feet. The operation employs about five men, and all of the logs are taken to a sawmill at Jakolof Bay on the Kenai Peninsula.4 There is no significant lumber or pulp manufacturing capabilty in the region. lyr. and Mrs. Bill Burton, owners, Burton Ranch Kodiak, October 1973. Personal communication. 2Ipid. 3Ipid. 4xarl Armstrong, Land Specialist, Koniag, Inc. Kodiak, October 1973. Personal communication. 509 @ A contract to cut approximately 525 million board feet on Chugach National Forest land from the Perenosa Bay area at the north end of Afognak Island (Figure 171) was sold by the U. S. Forest Service to Columbia Lumber Company of Alaska 1968. No action was taken on the sale due to a drop in the export market. Since that time the original purchaser has entered into a third-party agreement with Afognak Timber Company to operate under the contract. Because of environmental considerations, the timber sale was modified to reduce the total volume to be harvested to approximately 330 million board feet. The harvesting is to be carried out over a period of 10 years. The Afognak Timber Company is preparing to start logging operations and is presently looking for a site on which to construct a sawmill. The sawmill May not be located within the Western Gulf of Alaska. According to the environmental impact statement submitted by the U. S. Forest Service, the logging operation and the associated mill would employ 50 to 120 people and could result in an annual flow of wages paid to employees directly associated with the timber operation of about two million dollars (U.S. Forest Service 1973). Currently the final environmental impact statement is being prepared for submission to the President's Council on Envrionmental Quality. Minerals and Petroleum No major mineral or petroleum activity exists in the Western Gulf of Alaska although considerable mineral and oil exploration has occurred in the past. There are many mining claims in the region, but only a few are active; production is negligible. Gravel is the principal resource extracted from the Kodiak area, and sales of this material amount to approximately 200,000 dollars per year. Exploratory activities continue in the region on a limited basis with most of it being directed to oil and not to hard minerals. During 1972 geologic field crews of three major oil companies were active at Port Moller. Currently an exploratory oil well is being drilled on the north side of the Alaska Peninsula near the Cathedral River at Cape Leonivitch (Figure 171). As of mid-August 1973 the well had been drilled to 4,500 m.1 Tourism and Recreation Tourism is not a major activity in the Western Gulf region. Although the available data are quite sketchy, it appears that sign- ificant numbers of tourists come to only a few points within the region. Kodiak Island is the most popular tourist area, in part because it is the most accessible. There is excellent stream and lake fishing, as well as gun or camera hunting for the world famous Kodiak bear. Nearly half the guides registered in Alaska are licensed to guide on Kodiak Island. There are 12 registered guides who are residents on Kodiak Island, and more than half of these are listed as offering guide service lyr. Marshall, Petroleum Geologist, Alaska Department of Natural Resources, Division of Oil and Gas, August 1973. Personal communi- cation. 510 to hunt the Kodiak brown bear (U.S. Department of Commerce 1973). The U. S. Bureau of Sport Fisheries and Wildlife reports that guides who serve bear hunters alone gross well over 200,000 dollars annually and that the average expenditure of a nonresident hunter amounts to more than 3,000 dollars (U. S. Bureau of Sport Fisheries and Wildlife 1972). The city of Kodiak reported that a total of 6,000 visitors used the facilities under its jurisdiction in 1972 (Alaska Department of Natural Resources 1972). Seventy-five percent of these are nonresidents. Some of the attractions within the Kodiak area are the Old Russian Church, the Historical Society Museum, the fishing fleet, canneries, and the historical drama, "Cry of the Wild Ram," usually held at the Monashka Bay Amphitheatre. Statistics available for the Kodiak National Wildlife Refuge show that there were 7,681 visits for recreational purposes made to the refuge in 1971 (U.S. Bureau of Sport Fisheries and Wildlife 1972). Approximately half of these visits were made for hunting and fishing. Other recreational uses made of the refuge include trapping, picnicking, boating, and fruit and vegetable collecting. Visits made to the Aleutian Islands and Izembeck National Wildlife Refuges in fiscal year 1972 totaled 2,560 (Alaska Department of Natural Resources 1972). A portion of Katmai National Monument is in the Western Gulf area but virtually all visitors to that area enter via King Salmon or Naknek and remain in that part of the monument which is in the Bristol Bay region. The U.S. Forest Service maintains eight recreational cabins on Afognak Island. These cabins received 800 visitor days of use during the first nine months of 1973.! TRANSPORTATION FACILITIES AND COSTS Overview The principal means of transportation in the Western Gulf of Alaska are by air and sea. There are no links to the rest of the state by highway or rail and there are only a few local highway links with the region. The region's harbors are, however, accessible to deep-draft, seagoing vessels and its sea routes are usually ice free during the entire year. Kodiak and Port Lions are linked to the state's marine highway system. Air transportation within the region is well developed and there is daily jet service to the city of Kodiak from Seattle and Anchorage. Air and sea transport, particularly in the Alaska Peninsula and the Aleutians, is often hampered by severe weather conditions. With the exception of the city of Kodiak, transportation costs within the Western Gulf of Alaska are high. gordon P. Edgars, Acting Resource Management Assistant, U.S. Forest Service, Kodiak, Alaska, October 1973. Personal communication. S11 Transportation Facilities Airports There are airports or float plane landing sites for nearly every village in the Western Gulf region. Protected bays and coves provide seaplane landing sites most of the year. The region's lakes and rivers make the area accessible to float planes in summer, and to ski-equipped planes in winter. There are seven trunk airports which have runways 1,050 m. or longer and are capable of handling large aircraft. All are equipped with lights and can handle nighttime traffic. The airports at Cold Bay and Kodiak can handle large jet aircraft and, along with the airport at the Sitkinak Coast Guard Station, are the only airports in the region with paved runways. Cold Bay and Kodiak have facilities for plane handling, maintenance, and traffic control. Except for the trunk airports, the airports and landing sites in the region are suitable only for small aircraft. They have runways shorter than 1,050 m. and are unlighted. Statistics on the region's airports are shown in Table 87. Roads Most roads in the Western Gulf region are located in the northeast portion of Kodiak Island. Cold Bay is the only other area in the region where there is any extensive road network. A few other village have local service roads which represent very little areas. There are approximately 184 km. of state roads and 22 km. of city roads on Kodiak Island (Kodiak Chamber of Commerce 1973). Of this, about 10 percent is paved, 80 percent graded and drained gravel or dirt, and the remaining 10 percent is unimproved. 1! Most roads connect the city of Kodiak with the various military installations on the island and most of the cattle ranches. Afognak Island, north of Kodiak Island, has one unimproved road which is approximately 8 km. long and extends from Afognak Bay to Afognak Lake where there is a military reservation camp (U.S. Forest Service 1970). The Cold Bay road network extends approximately 80 km. and primarily provides access to various military sites and to the harbor (U.S. Geological Survey 1943). Within the next five year period, road construction and upgrading will take place on a small scale within the region, according to current State Highway Department plans. All of this work will take place on Kodiak Island. The estimated cost of this activity for the period 1973 through 1977 is approximately seven million dollars (Table 88). The work will primarily consist of reconstruction, paving, and bridge building. Harbors The harbors of the Western Gulf of Alaska accommodate deepdraft ocean vessels and most have facilities for off-loading freight. The majority of these facilities are owned and operated by fish processing lEstimated from Alaska Department of Highways, General Highway Maps, 1965-1967. Table 87 PRINCIPAL AIRPORTS WESTERN GULF OF ALASKA - 1973 | ee Stave Meat) || See Teinition Akhiok Unusable Dirt Cape Sarichef AFS 3500x120 Gravel Lighted Chignik 1340x50 Dirt 206 83 Chignik Lagoon 2250x35 Gravel Goose 54 Chignik Lake Gravel Under construction Cold Bay 5126x150 Asphalt DC-8 185 Lighted 10, 128x150 Asphalt Lighted Karluk Lake Beach Goose 98 King Cove 4000x100 Gravel DC-3 283 Lighted Kodiak 7500x150 Asphalt Lighted 5000x150 Asphalt 720 3798 Lighted 5000x150 Asphalt Lighted Old Harbor 2000x100 Gravel 402 290 Port Lions 2600x150 Gravel 402 227 Sand Point 3800x150 Gravel Sitinak CGS 4500x150 Asphalt Lighted Sources: Alaska Legislative Council 1972, Alaska, Dept. of Public Works, Division of Aviation -"Landing Area Inventory - 1973" - prepared for the Joint Federal State Land Use Planning Commission. z1s Table gg PROPOSED HIGHWAY AND SERVICE ROAD CONSTRUCTION ACTIVITIES: FOR WESTERN GULF OF ALASKA 1973 - 1977 Estimated Yearly Project Location Project Description Total Cost Subtotal Total Jol lars Construction and Improvement of Major Roads 1973 Kodiak Highway Mill Bay Road, pave 2.6 mi. $ 250,000 Rezanoff Drive Pave 1.9 miles of existing 311,000 (Kodiak) street Cape Chiniak Kodiak Naval Air Station, (Kodiak) mile 0 to mile 2.2. Re- construction on new alignment and pave including construction of two bridges 1,949,000 $2,510,000 1974 None 1975 Cape Chiniak Mile 2.2 to mile 7.2. (Kodiak) Reconstruction on existing alignment and pave 5.1 miles including con- struction of six bridges $2,300,000 1976 None Construction and Improvement of Local Service Roads and Trails 1973 Kodiak Marine Way, pave from Rezanoff Drive to 6th Avenue $ 20,000 Kodiak Is. Borough Reconstruct Melnitsa Lane 66.000 1974 Kodiak Is. Borough Reconstruct Lakeview Drive $15,000 1975 Kodiak Mission Road, pave from 10th Avenue to city limits $ 15,500 Kodiak Is. Borough Otmeloi Way, con- struct from Miller Point Road to Mill Bay Road 70,000 lee y_ 85, 000 186,500 GRAND TOTAL $77,056,000 *Specific cost information not available Source: Alaska Department of Highways 1972, 513 514 plants. Some of the harbors offer facilities to haul boats out of the water and make minor repairs. A few can provide supplies such as food, fresh water, and marine hardware. Information concerning the facilities and supplies available at each harbor in the region is provided in Table 89. The city of Kodiak has by far the most developed harbor facilities in the Western Gulf. These include two cargo docks, a ferry dock, two transient floats, and a small boat harbor. The two cargo docks handle most of the freight coming into Kodiak. One of these includes a recently completed container dock with a "Super Sam" crane capable of unloading containerized freight weighing up to 20 metric tons. This dock is principally used by Sea Land, Inc. which has a preferential use agreement with the city. The other cargo dock (108 m. long) serves only for off-loading non-containerized freight and has no crane. There is only one small warehouse serving both docks. The ferry dock also serves as a fuel off-loading facility and is used by fishermen. The small boat harbor has 226 permanent berths which is inadequate to meet current needs.! There is a waiting list of some 300 vessels for berths. It is estimated that during the summer months 650 vessels use the small boat harbor. About 95 percent of these are fishing vessels. The harbor has two unloading docks (51 and 45 meters long) and two grid irons for boat repairs. There are two transient floats in Kodiak Harbor; one is located within the small boat harbor and can accommodate 30 vessels and the other is located in the Near Island Channel and can handle between 50 and 60 vessels. Transportation Services Passenger Service Most passenger traffic in and out of the Western Gulf of Alaska is by air. Two certificated route carriers, Western Airlines and Wien Air Alaska, Inc., serve the region, along with several air taxi operations, two of which operate out of Kodiak. Nearly all of the Western Gulf villages listed in the U.S. Census are serviced by scheduled commercial air flights (Figure 172) and the majority of these receive scheduled service two or more times a week (Tables 90 and 91). As shown in Table 92, Kodiak and Cold Bay have the region's busiest airports. During fiscal year 1971, nearly 40,000 passengers enplaned at Kodiak, representing 73 percent of the region's total passenger traffic. Cold Bay accounted for 6,800 passengers, or 12 percent of the total commercial passenger traffic within the region. Kodiak Island is also on the Southwest Marine Highway System. During the summer, the ferry M/V Tustumena stops at Kodiak and Port Lions three times a week, providing service to Seward, Seldovia, Homer, and Anchorage. During the winter, ferry service is reduced to twice a lyarbormaster, City of Kodiak. October 1973. Personal communication. Harbor KODIAK ISLAND Kodiak 515 Table g9 HARBOR FACILITIES - WESTERN GULF OF ALASKA DESCRIPTION OF DOCK, WHARFS OR PIERS Face (ft). Depth Along Side (ft). Other 360 170 150 68 (new container dock)n.a. Women's Bay Ouzinkie Shearwater Bay Old Harbor Moser Bay Lazy Bay Olga Bay Port William Larsen Bay Iron Creek Port Vita (Vista) Port Wakefield Sheep Island Port O'Brien Zachar Bay Port Baily 1200 500 104 100 25 n.at 140 110 105 30 100 150 30 Supplies Available: 19 marine hardware, fresh water, 30 gasoline, diesel oil, kerosene 70 and lubricating oils. General n.a. repairs can be made by local machine shops. Large container crane. 27 28 Naval Defensive Sea Area 28 17 Timber skidway which can handle 38-ton craft face of wharf becomes dry 4' above low water 20 Slipway canable of hauling 28 out vessels up to 130 tons 11 Supplies available: fresh 21 water, diesel fuel, gasoline na. Marine railway can handle boats up to 100 gross tons 18 15 19 Supplies available:fresh water, 30 machine shop scow ways 20 20 18 Supplies available: fresh water, n.a.* fuel oil, diesel oil, gasoline, marine hardware. Machine shop at cannery. (continued) Table g9 (continued) HARBOR FACILITIES -WESTERN GULF OF ALASKA DESCRIPTION OF DOCK, WHARFS OR PIERS Face (ft). Harbor ALASKA PENINSULA - ALEUTIANS Chignik 62 Chignik Lagoon na. Ivanoff Bay na. Sand Point 180 60 Baralof Bay 190 King Cove * * Depth Along Side (ft). 18 dry in low water 22 24 15 27 Wharf has two faces can handle vessels up to 4,800 Cold Bay 500 False Pass 225 Port Moller 145 *Information not available 30 26 25 516 Other Machine shop. Supplies available: gasoline, ker- osene, lubricating oil, diesel oil, fresh water, marine hardware Supplies available: fresh water, machine shon, fuel oil, gasoline Supplies available: fresh water, coal and gasoline. Has slipway for vessels up to 100 feet in length. Supplies available: gasoline, fuel oil, fresh water Source: U.S. Department of Commerce, Coast and Geodetic Survey, United States Edition including 1966 and 1971 supplements. Coast Pilot 9 - Pacific and Arctic Coasts, ALASKA Seventh (1964) ‘0 CHERNOFSKI Figure 172. Certified air carrier routes in the Western Gulf of Alaska (from Reuben H. Donnelley Corp. 1973). Zs NON-STOP KODIAK ISLAND SEPTEMBER 1973 Table 90 AIRLINE FLIGHTS 405 FROM: Flights One-way Type of per Week Flight time fare Aircraft* Akhiok Kodial 3 lhr. 5 ain. $36. LEC Akhiok McCord varies 25 min. GGS Alitak Akhiok s 29 min. GGS Alitak Moser Bay 3 40 min. GGS Anchorage Kodiak 8 45 min. 40. 737 Karluk Larsen Bay 3 20 min. GGS Kitoi Kodiak 3 15 min. 16. GGS Kodiak Alitak 4 lhr. | 5 min. 33. GGS Kodiak Anchorage 8 50 min. 40. 737 Kodiak Karluk 3 35 min. 33. GGS Kodiak Larsen Bay 3 1 hr. 5 min. 28. GGS Kodiak Old Harbor 6 30 min. 23. CES Kodiak Olga Bay 2 40 min. 33. GGS Kodiak Port Lions 12 15 min. 14. GGS Kodiak Port Williams 3 35 min. 23% GGS Larsen Bay Kodiak 1 lhr. 10 min. 28. GGS McCord Kodiak varies 30 min. 3 GGS Moser Bay Kodiak 3 45 min. 33. GGS Old Harbor Kodiak 12 30 min. 23; CES Olga Bay Alitak 2 15 min. GGS Ouzinkie Kodiak 6 10 min. 10. GGS Port Lions Kodiak 6 15 min. 14. GGS Port Lions Ouzinkie 3 35 min. GGS Port Williams Kitoi 3 20 min. 16. GGS *LEC=Lockheed Electra Turbo-Prop; GGS=Gruman G21A Goose; 737=Boeing 737 (all series). Source: Reuben H. Donnelley Corp. 1973. NON-STOP Table 91 AIRLINE FLIGHTS ALEUTIAN ISLANDS AND ALASKA PENINSULA SEPTEMBER 1973 Flights One-way Type of TO: FROM: per Week Flight time fare Aircraft* Adak Anchorage 3 2 hrs. 45 min. $173 LEC Adak Attu 1 lhr. 20 min. 93 LEC Adak Cold Bay 3 2 hrs. 128 LEC Adak Shemya Island 2 lhr. 20 min. 84 LEC Akutan Cold Bay 1 lhr. 15 min. 33 GGS Amchitka Adak 2 45 min. 54 LEC Anchorage Adak 3 4 hrs. 15 min. LEC Anchorage Cold Bay 8 3 hrs. 20 min 117 Y11/LEC Attu Shemya 1 15 min. ll LEC Cape Sarichef Cold Bay 2 35 min. 19 Y1l Chignik Port Heiden 2 30 min. 27 PRP Chignik Lagoon Chignik 2 10 min. 11 PRP Cold Bay Adak 3 lhr. 45 min. 128 LEC Cold Bay Akutan 1 3 hrs. 25 min. 33 GGS Cold Bay Anchorage 6 lhr. 30 min. 117 DC6/Y11/LEC Cold Bay Chernofski varies lhr. 50 min. 49 GGS Cold Bay Dutch Harbor 2 45 min. 33 Yl1l Cold Bay False Pass 3 lhr. 20 min. 22 PRP Cold Bay King Cove 3 15 min. 17 PRP Cold Bay Sand Point 3: 25 min. 27 Y1l Driftwood Bay Dutch Harbor 2 10 min. 21 yll Dutch Harbor Cape Sarichef 2 30 min. 15 Y1l Dutch Harbor Cold Bay 2 40 min. 33 Y1l Dutch Harbor Driftwood Bay 2 10 min. 21 Y1l Dutch Harbor Umnak 2 30 min. 23 Yl1l False Pass Cold Bay 3 45 min. 22 PRP Ivanoff Bay Perryville 2 10 min. 1l PRP King Cove Cold Bay 3 15 min. 17 PRP Nikolski Umnak 2 20 min. 11 Y1l Perryville Chignik Lagoon 2 50 min. 17 PRP Port Heiden Ivanoff Bay 2 lhr. 50 min. 35 PRP Port Heiden Sand Point 2 lhr. 40 min. 44 PRP Port Moller Port Heiden 2 22 Y11 Sand Point Cold Bay 2 30 min. 27 Yl1l Sand Point Port Heiden 1 44 Yll Sand Point Port Moller 2 10 min. 22 Yi Shemya Adak 1 lhr. 35 min. 84 LEC Shemya Amchitka 2 50 min. 47 LEC Umnak Dutch Harbor 2 20 min. 23 Yll Umnak Nikolski 2 20 min. 11 YLL ®PRP=Prop Aircraft, type varies; GGS= Gruman G21A Goose; DC-6=Douglas DC6. Source: Reuben H. Donnelley Corp. 1973. LEC=Lockheed Electra Turbo-Prop; Yll=Namco YS-11; 519 520 week and there is no service to Anchorage or to Port Lions. In the two year period 1970-72, annual travel to Kodiak by ferry averaged 3,370 passengers and 73 cars (Alaska Department of Public Works 1972). The Kodiak urban area is currently serviced by a licenses franchised bus company which provides school bus service, airport passenger service and charter service. The city is also served by a taxi company which offers 24 hour service. Freight Service Air freight and U. S. mail are carried by both the certificated route air carriers and the authorized air taxis serving the region. Most of this freight passes through Kodiak and Cold Bay (Table 92). Kodiak handled 815 metric tons of freight and mail in fiscal year 1971 or 52 percent of the freight carried by commercial carriers in the region. Cold Bay handled 648 metric tons or 42 percent of the total carried. Mail accounts for much of the air cargo carried by certificated air carriers in the region, particularly to the smaller communities. Over half of the communities listed in Table 92 receive more tonnage of U.S. mail than they do regular air freight. This is due to postal service regulations for transport of intra-Alaska mail which permit a wide range of goods to be shipped by parcel post. The parcel post rate is lower than the air freight rate because of a subsidy paid to the airlines by the U. S. Postal Service. Naturally this encourages shippers to use the U. S. Postal Service as a major freight mover in rural Alaska. Much of the freight previously moved by barge or ship is now shifting to parcel post as stores find that they can operate with lower inventory investment by paying just a little more for mail delivery of their goods (Alaska Legislative Council 1972). The city of Kodiak is the principal harbor of the Western Gulf of Alaska and the major transhipment point for freight destined for the Aleutians, Alaska Peninsula, and Bristol Bay. None of the other harbors handles enough freight to be considered individually in the annual statistics of the U.S. Army, Corps of Engineers (1960-1971). The amount of freight received, shipped, or transferred in Kodiak harbor from 1960 through 1971 is shown in Table 93. Most freight is fuel oil, gasoline, and outbound fish products. There is regular sea freight service to the city of Kodiak from Anchorage and Seattle. Scheduled service is provided by Sea Land Service, Inc. two to three times per month. Western Pioneer Lines, Foss Launch and Tug, Puget Sound Tug and Barge, and Northland Marine Lines provide unscheduled service to the city. There are two petroleum products distributors that also provide regular service to Kodiak. Freight service to the outlying villages of Kodiak Island is unscheduled. Western Pioneer Lines serves many of the locations which have fish processing plants and transports fish products to Seattle. Some freight is handled by private fishing boats and cannery tenders. Table 92 AIRPORT ACTIVITY STATISTICS OF CERTIFICATED ROUTE AIR CARRIERS -FY 1971 Airport Akhiok Karluk Kitoi Bay Kodiak Larsen Bay Moser Bay Old Harbor Ouzinkie Port Williams Cold Bay False Pass King Cove Pauloff Harbor Perryville Sand Point TOTAL Source: AIRPORT ACTIVITY - WESTERN GULF OF ALASKA Enplaned Passengers 700 869 105 39,894 75 334 2,094 2,059 183 SOUTH ALASKA PENINSULA - ALEUTIANS Freight tons) KODIAK ISLAND 0.77 1.79 1.78 552.26 0.46 0.49 3.33 1.42 0.44 Mail (tons 1.81 2.37 0.09 345.97 0.41 0.21 4.36 2.82 0.19 6,742 220 430 23 4 809 54,746 354.28 1.28 4.32 0.25 0.19 7.87 954.24 360.06 4.01 11.28 1.38 20.99 760.95 U.S. Department of Transportation 1972. Total Cargo and Mail (tons) 4.16 1.87 898.23 0.87 0.70 7.69 714.34 15.60 28.86 1,715.19 $21 522 Table 93 FREIGHT TRAFFIC MOVING THROUGH KODIAK HARBOR 1960-1971 Year Tons of Freight Received, Shipped or Transferred 1960 38,289 1961 39,623 1962 80,267 1963 73,775 1964 62,285 1965 127,584 1966 212,675 1967 133,247 1968 109,645 1969 115,863 1970 124,479 1971 148,444 Source: U.S, Army, Corps of Engineers 1960-1971. 523 Sand Point receives scheduled freight service once a month from Sea Land Service, Inc. Western Pioneer Lines, Inc., Foss Launch and Tug, Puget Sound Tug and Barge, and Northland Marine Lines provide unscheduled service to most of the Alaska Peninsula and Aleutian ports, particularly to those areaa which export fish products to Seattle. Transportation Costs One way commercial airline passenger fares for some of the direct flights between communities of the Western Gulf of Alaska and Anchorage and of flights within the region are shown in Tables 90 and 91. In general, the passenger cost per kilometer tends to be higher in Alaska than for comparable distances in the contiguous United States due to the lower traffic volume and higher operation and maintenance costs in Alaska (Table 94). Air freight rates for general and specific commodities between Western Gulf communities and Seattle are shown in Table 95. The general commodity rate is usually higher than the rates given to those specific commodities handled frequently and in large volume. Air freight is flown directly to Kodiak from Seattle, whereas freight going to the Alaska Peninsula and the Aleutians has to be transshipped at Anchorage. There are no specific commodity rates between Anchorage and communities in the Western Gulf of Alaska; all goods are charged the general commodity rate. If an unweighted average is calculated for the rates shown in Table 95, the average cost of shipping goods by air to Kodiak is about 15 percent higher than the cost of shipping to Anchorage, even though these cities are approximately equal distants from Seattle. Goods are freighted from Seattle to Alaska Peninsula or Aleutian communities via Anchorage are charged an additional $30/cwt. for the transport from Anchorage. Again using an unweighted average, the rates from Seattle to Cold Bay are nearly 150 percent higher than those from Seattle to Anchorage. The average air freight rates for southbound seafood, when compared with those from Anchorage, are 37 percent higher from Kodiak and well over 100 percent higher from Chignik, Sand Point or Cold Bay. Sea freight rates between Seattle and Kodiak average considerably less than rates to other areas in the Western Gulf (Table 96). According to the tariffs of Sea Land, Inc., typical rates to outlying communities of Kodiak are 20 percent more than those to Kodiak. Rates to Chignik are 300 percent higher and those to Sand Point, False Pass and KingCove are 66 percent higher. Southbound shipments of canned seafood cost only one percent more to ship from outlying Kodiak are 20 percent more than those to Kodiak. Rates to Chignik are 33 percent higher and those to Kodiak. Rates to Chignik are 33 percent higher and those to Sand Point, False Pass, and King Cove are 66 percent higher. Southbound shipments of canned seafood cost only one percent more to ship from out- lying Kodiak communities than from Kodiak. Southbound rates from Chignik are eight percent higher, while those from Sand Point, False Pass, and King Cove are 36 percent higher. 524 Table 94 COMPARISON OF COMMERCIAL AIRLINE FARES WITHIN THE WESTERN GULF OF ALASKA AND BETWEEN THE WESTERN GULF AND ANCHORAGE (With Fares for Comparable Distances in the Contiguous United States) Tourist Passenger One-Way Fare Cost per Mile* Pair (tax included) Distance Anchorage - Cold Bay $ 117.00 625 miles $ 19 Anchorage - Kodiak 40.00 250 miles .16 Cold Bay - Port Moller 27.00 103 miles 26 *Cost per mile computed from Direct Distance Between Points and Tourist are as of Sept. 1, 1973 Source: Reuben H. Donnelley Corp. 1973. 525 Table 95 COMPARATIVE GENERAL AND SPECIFIC COMMODITY AIR FREIGHT RATES BETWEEN SEATTLE AND COMMUNITIES OF THE WESTERN GULF OF ALASKA + (dollars per 100 lbs.) To TO TO CHIGNIK2 FROM SEATTLE ANCHORAGE KODIAK SAND POINT es ae = COLD BAY — General Commodities $ 22.10 $ 29.50 $ 52.10 Meat 19.20 24.50 49.20 Milk 16.90 19.20 46.90 Eggs 22.10 21.45 52.10 Produce 19.20 21.45 49.20 Household Goods 22.10 24.50 52.10 Personal Effects 22.10 24,50 52.10 From FROM FROM CHIGNIK TO SEATTLE ANCHORAGE KODIAK SAND POINT Seafood 10.00 13.65 22.00 Canned seafood 10.00 - 20.20 1 Airfreight to Anchorage and Kodiak is direct from Seattle. To Chignik, Sand Point and Cold Bay air freight travels via Anchorage. 2Rates between Anchorage and Chignik, Sand Point and Cold Bay are based on a general commodity rate of $30/cwt. except for fish which is $10/cwt. Sources: Official Air Freight Local Rates Tariff No. LR-1- Reeve Aleutian Airways Inc., Wien Alaska Inc., Western Air Lines. From Seattle Cement, sand, gravel Building woodwork Metal collapsed cans in pkg. Dairy Prod., fresh, refrig. Fruits, Veg., frozen Motor Vehicles Iron and steel articles Lumber, rough or surfaced Eggs (in wooden cases) Meat, fresh (not frozen) Compressed gases Salt Average additional cost northbound (percent) Fish canned (southbound) TO SEVERAL COMMUNITIES OF THE WESTERN GULF OF ALASKA FROM SEATTLEL To Kodiak I. 8. N Ww Oo + 2. 2 Table 96 COMPARATIVE SEA FREIGHT COSTS OF VARIOUS COMMODITIES 70 34 -20 02 +92 51 01 +62 -66 -21 +17 32 32 (dollars per 100 lbs.) To Kodiak Is. Outlying Communities 2335 9.68 2.55 7.04 9.21 9.17 3.53 2.86 5.25 12.52 3.55 2.45 2.35 Additional Cost’ (percentage) 38 16 16 40 16 8 17 9 13 52 12 7 20 1 To Chignik 2.59 10.66 2.80 7.74 10.14 10.14 5.79 13.70 3.88 2.51 Additjonal Cost (percentage)King Cove 52 28 27 54 28 19 30 22 24 67 22 16 32 8 To Sand Point False Pass 3.24 13.32 3.51 9.67 12.68 12.68 7.23, 17.13 4.86 3.15 Additonal Cost (percentage) 91 60 60 93 60 49 71 52 55 109 53 45 66 36 lthese costs are 7% higher than those stated in the published tariffs because published tariffs do not reflect a the most recent price increases ‘As compared to shipping cost to Kodiak. Source: Sea Land Freight Tariffs 139 and 197 925 527 In general, the rates from Seattle to Kodiak are significantly higher than the rates to Anchorage. This is due solely to the much larger volumes that are involved in the Anchorage shipments. It is interesting to note that for smaller shipment sizes the rates to Anchorage are actually higher than those to Kodiak. LAND USE AND LAND status! Background Information In discussing the land use and land status of the Western Gulf of Alaska, the land area on the north side of the Alaska Peninsula from approximately Ilnik to Unimak Pass will also be included as this area is socially and economically related to the Western Gulf. The eastern boundary on the Alaska Peninsula was chosen to coincide with the Aleut regional Native corporation boundaries. Land use and land status on both sides of the Alaska Peninsula from this eastern limit westward will be significantly influenced by the Aleut corporation and its member villages. The Western Gulf of Alaska is currently undergoing a redistribution of land under the provisions of both the Alaska Statehood Act (U.S. 72 Stat. 339) and the Alaska Native Claims Settlement Act (ANCSA) (P.L. 92- 203). Until final implementation of both these Acts, land ownership patterns and the uses permitted on the land will be changing constantly. These Acts will eventually produce three major land owners in the region: the federal government, the state and its municipalities, and the Alaska Natives. The Alaska Statehood Act (1959) provided a grant of federal lands to the state amounting to 43.2 million hectares (104.6 million acres). These lands are to be selected by the state from any open, available public domain lands owned by the United States. The state has selection rights until January 1984. State land selections in the Western Gulf are shown on Figure 173. ANCSA, passed in 1971, provides for selection and conveyance of 16.2 million hectares (40 million acres) of land to Alaska Natives and provides for the redistribution of most of the state's lands. The provisions of the Act have priority over the land selection provisions in the Alaska Statehood Act. Because of this priority, state selection rights have been nullified on some lands and delayed on others. Under provisions of ANCSA, the Secretary of the Interior has withdrawn from the jurisdiction of the public land laws most of the public domain lands of Alaska. For the state as a whole, these withdrawals include: Approximately 42.9 million hectares (106 million acres) from which the Natives of Alaska can select their 16.2 million hectares (40 million acre) entitle- ment. Information contained in this chapter is based upon the lands situation as of September 1, 1973. 59° 57° 55° 166° MAJOR WITHDRAWALS PRIOR TO ANCSA 0-1 LANDS-CLASSIFICATION AND PUBLIC INTEREST AREA D-2 LANDS-NATIONAL INTEREST STUDY AREA POSSIBLE ADDITIONS TO NATIONAL WILDLIFE REFUSE SYSTEM STATE SELECTIONS PATENTED STATE SELECTIONS TENTATIVELY APPROVED STATE SELECTIONS PENDING Figure 173. Land status in the Western Gulf of Alaska. 156° 154° 152° 87S 529 3.0 million hectares (7.5 million acres) for utility corridors. 770,000 hectares (1.9 million acres) for possible additions to the National Wildlife Refuge System. 32.4 million hectares (80 million acres) of lands of significant national importance to merit class- ification as a National Forest, Park, Wild or Scenic River, or Wildlife Rufuge (D2 Lands). 30.8 million hectares (76 million acres) of lands of significant public interest to warrant future class— ifiaction by the Secretary of the Interior (D-l Lands) .4 With the exception of utility corridor withdrawals, all these categories of land are represented in the Western Gulf of Alaska region and are shown on Figures 173 and 174. Current Land Use The economy of the Western Gulf of Alaska is primarily marine based. Intensive land use occurs only where land is used for a community site or a military site. However, the land area of the Western Gulf is used extensively for subsistence, livestock grazing, and recreational activities. Primarily, subsistence activities on the land consist of hunting and trapping. The areas used by the Natives of Kodiak Island for subsistence activities on the island and along the west shore of Shelikof Strait are shown on Map 4. Little information is available concerning the specific subsistence areas used by Alaskan Natives in other areas of the Western Gulf. No records are available which show the number of animals harvested for subsistence purposes in the Western Gulf. In the Kodiak area and that portion of the Alaska Peninsula across Shelikof Strait from Kodiak Island, the principal species harvested are the Sitka black-tailed deer, beaver, land otter, and red fox. Harbor seals are harvested in the adjacent waters. Elsewhere on the Alaska Peninsula that is in the Western Gulf and on the eastern Aleutian Islands, beaver, muskrat, mink, land otter, weasel, and fox are the principal species harvested. Moose and caribou are hunted on the Alaska Peninsula and Unimak Island and throughout the area large numbers of waterfowl are harvested (Federal Field Committee for Development Planning in Alaska 1968). Livestock (cattle and sheep) grazing utilizes 158,000 hectares of land in the Western Gulf of Alaska. This range currently supports about 4,600 head and has an estimated total carrying capacity of 6,500 head (Table 86 ). Recreational use takes place over much of the area. Trophy hunting for brown bear is popular on Kodiak Island and on the Alaska Peninsula where trophy moose are also found. Archeological sites represent another type of land use in a historical sense. Many sites have been found in the Western Gulf of lpublic Law 92-203 (Sec. 11), Public Land Orders: 5150, 5169, 5178, 5810, 5181, 5182, 5190, 5192, 5193 and League of Women Voters 1973. 57° 56° 55° 166° REGIONAL CORPORATION BOUNDARIES NATIVE VILLAGE WITHDRAWALS CORE TOWNSHIPS VILLAGE DEFICIENCY MAJOR CONCENTRATION OF NATIVE ALLOTMENT APPLICATION Figure 174, Alaska Native Claims Settle- ment Act land classification in the Western Gulf of Alaska, 156° 154° “152° Ofs 531 eo Alaska, especially on Kodiak Island (Figure 175). Records kept by the State Division of Parks indicate that there are 292 known sites on Kodiak Island and 72 sites on the remaining portion of the Western Gulf area. Probably only half of the sites in the area have been discovered, especially on the coastal areas which historically supported greater human populations because of the more constant food supply provided by the sea. Land Status The Western Gulf of Alaska as defined on Figure 171 contains approx- imately 4,398,000 hectares.3 The area currently contains 17 categories of lands. Some categories represent a permanent determination of land status while other are only temporary classifications. The total area in the different categories exceeds that of the region by about 800,000 hectares (two million acres) (Table 97) because the withdrawals created by ANCSA overlap previously withdrawn federal lands and lands selected by the state in accordance with the Statehood Act. In addition, some of the Native village withdrawals overlap each other. A discussion of each land category including the present status and the constraints to use follows. The land use constraints on each category can be seen in Tables 98, 99, and 100. Lands With a Permanent Status Classification Because of the nature of some lands in the Western Gulf of Alaska their withdrawal has permanent status. These include Katmai National Monument, Chugach National Forest lands, military reservations, National wildlife refuges, power sites or project withdrawals, outer continental shelf lands, and state patented and private patented lands. These lands, with the exception of power sites or project withdrawals, continental shelf and private lands, are shown on Figure 173. All categories except continental shelf lands are in Table 97. Katmai National Monument Approximately 353,245 hectares of Katmai National Monument are in the Western Gulf of Alaska. Land use in this area is quite restricted because the area was originally withdrawn to protect unique geologic features and later expanded to protect wildlife habitat (Table 99). This area is withdrawn from appropriation under the public land laws, location and entry under the mining laws, and leasing under the Minerals lpr. Karen Workman, Archeologist, Alaska Department of Natural Resources, Anchorage. July 1973. Personal communication. 2Ibid. 3This figure was calculated by extracting figures from the Bureau of Land Management's computer print-outs for the Native Regional Corporations within the Western Gulf. The lands were as follows: Aleut - 1,675,800 hectares e@ Bristol Bay - 832,750 hectares Koniag - 1,889,700 hectares 59° 58° 57° 56° 55° Figure 175. 166° ARCHEOLOGICAL SITE x Known archeological sites in the Western Gulf of Alaska (from the files of the Alaska Department of Natural Resources). 154° 152° WSs Table No. 97 LAND STATUS WESTERN GULF OF ALASKA - 1973 STATUS CATEGORY ACRES* Patented Lands Private 10,015 State 3,900 State Selections Tentatively Approved 641,347 Pending 1,601,853 Native Allotment Applications 35,085 Indian Reserves 25,409 Military Reservations 47, 262 National Forest 464,292 National Monument 872,858 National Wildlife Refuge 2,912,636 Power Site or Project and Other Withdrawals 20,675 Lands Withdrawn Under ANCSA Classification and D-1 Lands 874,697 D-2 Lands 627,786 Wildlife Refuge Replacement 452,643 Village Withdrawal 3,356,407 Village Deficiency 934,117 Regional Deficiency 820 Total Land Acres Withdrawn 12,881,802 Total Land Acres in Region 10,868,000 *Land acres only Source: U.S. Department status computer Regional Native of the Interior, Bureau of Land Management, land printouts of the Aleut, Bristol Bay and Koniag Corporations, July 1973. Table 98 CONSTRAINTS TO USE ON LANDS WITHDRAWN UNDER ANCSA AND REVOKED INDIAN RESERVE LANDS Wildlife Revoked Village Regional D-1 and Refuge Indian Village Deficiency Deficiency Classification Replacement Reserves D-2 Lands Withdrawals Withdrawals Withdrawals Lands Lands Expiration Date 12/18/73 12/18/78 12/18/78 12/18/78 12/18/78 Indefinite Indefinite Appropriation Under No No No No No No No Public Land Laws Location and Entry No No No No No For metali- No Under Mining Laws ferous min- erals only Leasing under Min- No No No No No No No erals Leasing Act of 1920 Hunting, fishing and Yes Yes Yes Yes Yes Yes Yes other forms of recrea- tional use Grazing Yes* Yes# Yes Yes* Yes* Yes Yes Timber Harvesting Yes Yes? Yes Yes* Yesa Yes* Yes* 4Provisions for interim administration in Section 17 of ANCSA authroize the Secretary of the INterior to make contracts and to grant leases, permits or easements on these lands. Under present Bureau of Land Management policy this authority is rarely exercised and very few uses are permitted on the land. bes Sources: Public Law 92-302 (ANCSA); Public Land Orders 5169 through 5188. Table 99 CONSTRAINTS TO USE ON LANDS WITHDRAWN PRIOR TO ANCSA AND PENDING STATE SELECTIONS Katmai Chugach National Outer Pending National National Military Wildlife Power Sites Continental State Monument __ Forest Reservations Refuges or Projects Shelf Selections Appropriation Under No Under Public Land Laws Mining Laws No No No No No Location and Entry No Yes No Yes Under Mining Laws Except Kodiak Yes No No Leasing Under min- No Yes No Yes Yes Yes No erals leasing Act of 1920 Hunting, fishing and Yes Yes Yes No hunting Yes N/A Yes other forms of recrea- (No hunting) or fishing tional use on some Grasing No Yes Yes Yes Yes N/A Yes? Yes Yes N/A Yes N/A Yes@ Timber harvesting No @The Secretary of the Interior has interim administrative authority on these lands giving him the right to make con- tracts and to grant leases or easements on these lands. Sources: U.S. Public Law 92-203 (ANCSA); U.S. Public Land Orders 5169 through 5188. sgs Classification Unclassified lands Agricultural lands Commercial lands Grazin g lands Industrial lands Material lands Mineral lands Public recreation lands Private recreation lands Residential lands Reserved use lands Timber lands Utility lands Watershed lands Open-to-entry Tide and submerged lands LAND USE CONSTRAINTS GOVERNING LAND UNDER THE Table 100 JURISDICTION OF THE STATE OF ALASKA Disposal no lease lease lease lease no no* no lease lease no no lease no lease lease or sale or sale only or sale or sale or sale or sale or sate or sale Mineral Deposits Acquired claim staking leasing leasing claim staking leasing claim staking claim staking leasing leasing leasing leasing claim staking claim staking leasing leasing * except those acquired by escheat or foreclosure Source: Disposal of Timber and/or Materials no yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes Alaska Statutes, Title 38; Alaska Administrative Code, Title II. Grazing no short term lease short term lease yes short term lease yes yes no short term lease short term lease no yes short term lease yes no nea. Recreation yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes 9¢S 537 Leasing Act. No hunting is allowed, but subsistence fishing is permitted along with sport fishing, berry picking, and other recreational uses. The state does not have selection rights on lands in Katmai National Monument. National Forest Lands: The Western Gulf of Alaska contains 187,900 hectares of Chugach National Forest lands. This land is closed to appropriation under all the public land laws except the public mining laws which permit location, entry, and patent. Mineral leasing is permitted under the Mineral Leasing Act. The various renewable surface resources of the national forests are managed under the principles of the Multiple Use Act of 1960. The Alaska Native Claims Settlement Act names three Native villages which can exercise land selection rights in the Chugach National Forest; Port Lions, Ouzinkie, and Afognak. Under the provisions of the act no village can select more than 27,973 hectares (69,120 acres) of National Forest land. If each village exercised its selection privileges to the maximum, all or part of approximately 10 townships could be converted to Alaska Native ownership. Koniag, Inc. is currently trying to obtain eligibility for three more villages within the Chugach National Forest on Afognak Island. The proposed villages are Port Williams, Kitoi, and Litnik. If the villages become eligible to select land under ANCSA, an additional 83,918 hectares (207,360 acres) could be selected from the National Forest area. National Forest lands covered by village withdrawals are closed to all forms of appropriation under the public land laws and from location and entry under the mining laws. Interim administration of the lands covered by village withdrawals prior to conveyance will be the responsibility of the Secretary of Agriculture who has the authority to make contracts and issue leases, permits, rights-of-way, or easements. Before any of the preceding activities take place the Secretary shall obtain the views of the concerned regional corporation or villages having interest in those lands. ! The State of Alaska does not have selection rights for Chugach National Forest lands on Afognak Island. National Wildlife Refuges: The Western Gulf of Alaska includes several National Wildlife Refuges containing 1,178,744 hectares (Table 97). Kodiak National Wildlife Refuge is the largest with 695,802 hectares. Other refuges include those in the eastern Aleutian Islands, namely Izembeck, Semidi, Simeonof, and Aleutian Islands National Wildlife Refuges. Under ANCSA several villages have selection rights on these wildlife refuges. The U.S. Bureau of Sport Fisheries and Wildlife estimates that Native entitlements for the villages of Kaguyak, Alitak, Old Harbor, and Larsen Bay will remove approximately 111,890 hectares lfederal Register, Title 43, Vol. 38, Subpart 2650, Section 2650-1, May 30, 1973. 538 from the Kodiak National Wildlife Refuge (U.S. Bureau of Sport Fisheries and Wildlife 1972). Village selections of False Pass, King Cove, and Belkofsky could take as much as six townships from the Izembeck refuge. The villages of Uganik and Ayakulik which border the refuge are also being considered for eligibility under ANCSA. If these villages obtain selection rights under ANCSA an additional 55,945 hectares could be withdrawn from the refuge. All refuge lands are closed to appropriation under the public land laws. Most uses are allowed on a permit basis or in specified areas. However, hunting and fishing are not allowed on the Simeonof and Semidi Refuges which were established to protect sea otters, sea birds, and sea lion rookeries respectively. Mining pf hardrock minerals is not permitted on the Kodiak Refuge. Regulations issued under the Alaska Native Claims Settlement Act contain provisions whereby lands selected from the refuge will remain subject to the laws and regulations governing the use and development of the refuge. Also, the Native corporations are not entitled to sub- surface rights on any land selected in the National Wildlife Refuges. 2 The United States government also reserves the right of first refusal if any refuge land is ever sold by any village corporation. The state does not have selection rights on national wildlife refuges. Military Reservations: There are approximately 19,000 hectares of military reservations in the region. Most is contained within the Kodiak Naval Station which was transferred to the United States Coast Guard in July 1972. Under provisions of Public Land Order 5187, all military reservations are closed to appropriation, mining, and mineral leasing (Table 99) in order to protect the public interest in the lands when they are no longer needed for military or defense purposes. Some uses are permitted at the discretion of the agency administering lands. While any of the area remains a military reservation, the state has no selection rights. Power Sites: There are approximately 8,367 hectares withdrawn for power sites or projects and other miscellaneous withdrawals. Power sites or power project areas are closed to appropriation under the public land laws but other uses may be permitted (Table 99). State and Private Patented Lands: State patented lands total approximately 1,580 hectares in the Western Gulf. These include state selections to which the state has received patent, mineral estate patents, airport conveyances, and quitclaim deeds. The figure shown in Table 97 does lyederal Register Section 2650, 4-6. 2P.L. 92-203 Section 14. 539 not include tidelands, submerged lands, and shorelands granted to the state in the Statehood Act.! state patented lands now represent a very small portion of the region, but if all the lands which are tentatively approved or pending approval are eventually patented, the state will have title to approximately 930,000 hectares or two percent of the region, exclusive of tide or submerged lands or lands under non-tidal navigable water. State patented lands, as well as those tentatively approved by the U.S. government for patent under the Statehood Act, are under state Management. These lands are unclassified but subject to eventual classification. The various classifications determine the use permitted. Land use constraints governing each classification are summarized in Table 100. All various land categories can be utilized for purposes "other than for which classified, provided such use is consistent with the public interest," according to the Alaska Administration Code. There are approximately 4,000 hectares of private patented lands in the Western Gulf of Alaska. The owner determines the use of the surface resources of the land and of its subsurface resources if he has subsurface rights. If the subsurface rights are reserved to the government, pros- pecting and oil and gas exploration can be conducted on the land by the owner or by someone other than the owner who would have to obtain a permit from the government. Because of their small size and scattered nature, private lands are not shown on the maps. Outer Continental Shelf Lands: These lands include the seabed and subsoil beyond the territorial limits (4.8 km.). Federal jurisdiction prevails in this zone to the 200 meter isobath, and the United States could claim beyond if it is capable of exploiting the subsoil and seabed resources (Hickok and Warnicke 1970). The laws and regulations which pertain to other public lands of the United States are not applicable to continental shelf lands. The lands cannot be appropriated and are not open to entry under the mining laws. lritle II of the Alaska Administrative Code defines these lands as follows: Submerged lands: +.-covered by tidal waters between the lines of mean low water and seaward to a distance of 3 geographical miles or further as may hereafter be properly claimed by the state." Tidelands: "...periodically covered by tidal waters between elevation of mean high tide and mean low tides." Shorelands: "...covered by non-tidal waters that are navigable under the laws of the United States up to ordinary highwater mark as modified by accretion, erosion or reliction." 540 Geological and geophysical explorations can take place and oil and gas can be extracted through lease. The United States reserves the right to helium from all gas produced in the area and to fissionable materials such as thorium and uranium. 1 Lands with a Temporary Status Classification State Selected Lands: The state has selected and not yet received patent for a total of 907,800 hectares under provision of the Alaska Statehood Act (Table 97). Approximately 259,000 hectares have been tentatively approved for patent. About 647,000 hectares are pending approval. The location of the tentatively approved and pending acreage can be seen on Figure 173. Under the provisions of ANCSA, each Native village corporation can select up to 27,973 hectares (69,120 acres) or three townships from state selected or tentatively approved land which was selected before January 17, 1969.2 There is no upper limit on the land the Native village corporations can select from state selections made after this date. There are approxiamtely 23 villages which could select lands from state selections and the amount each village corporation will select will not be known until after December 31, 1974, the deadline for village selections. State lands selected by village corporations will be made up from other land areas but not necessarily from within the Western Gulf region. Tentatively approved lands are under the management of the state and are subject to classification and the land use constraints discussed under patented state lands. State selected lands which are pending approval are administered by the Secretary of the Interior, who has the authority to make contracts, issue leases, permits, rights-of-way, or easements. Prior to this the Secretary of the Interior would obtain the view of the state. Land uses permitted on these lands can be seen in Table 100. Native Allotment Applications: Native allotment applications do not constitute a land withdrawal. Under Sec. 14(h) of ANCSA, a portion of 800,000 hectares (2 million acres) will be conveyed to Alaska Natives throughout the state to cover applications that were applied for under the Native Allotment Acts of 1887, 1906, and 1910 which were repealed by ANCSA. This land will also cover additional applications authorized by Section 12 (b) of ANCSA which conveys up to 65 hectares (160 acres) of land to a Native who applied for it within two year after the enactment of ANCSA as a primary place of residence on August 31, 1971. There are 14,200 hectares of allotment applications made prior to and after ANCSA in the Western Gulf area. The major portion of these are on Kodiak Island (Figure 174). lunited States Code Title 43, Section 1331. 2Federal Register Section 2651-4. 541 Lands Withdrawan Under Section D-2 of ANCSA: Under Section D-2, of ANCSA, lands were withdrawn for study and for possible recommendations to Congress as additions to or creation as units of one of the "four systems"; National Park, Forest, Wildlife Refuge, and Wild and Scenic River Systems. This withdrawal expires on December 18, 1978. The amount of D-2 lands withdrawn in the region totals 254,065 hectares. Land use constraints for these lands are indicated in Table 99. These lands are currently being reviewed by the Secretary of the Interior, who before December 18, 1973, must submit to Congress legislative proposals for their includsion in one of the "four systems." Lands originally withdrawn under the D-2 classification and not recommended for the "four systems" will be available for selection by the state, regional corporations, and for appropriation under the public land laws after they have been classified. Congress has until December 18, 1978 to act upon the Secretary's recommendations. After this date, lands not acted upon will be open to state selections and appropriation under the public land laws. Prior to December 18, 1978, the Native Claims Settlement Act permits the state and the Native regional corporations to identify D-2 lands desired for selection, but these can only be conveyed if they are not incorporated into the "four systems." The Secretary of the Interior can make contracts, grant leases, permits, rights-of-way, or easements. Mineral lease applications will be rejected until the public land order classifying D-2 lands is modified or the lands are reclassified to permit mineral leasing. Native Selections Under ANCSA: Lands withdrawn under ANCSA for Native selections also have a temporary status. The following statement explains for the state as a whole the Native land selection process and the role and time limits attached to each withdrawal category: The village land selection of 22,000,000 acres (8,900,000 hectares) for the whole State must be selected from lands designated as: a) village withdrawal area or b) village deficiency land if the regular withdrawal is insufficient. This land is selected by the village corporation. First to be selected are all available lands in the townships in which the village is located. Then additional land is selected based on village enrollment. The minimum entitlement for an incorporated village with an enrollment of at least 25 is three townships. This selection must be completed by December 18, 1974 and will result in surface lands going to residents, businesses, subsistence sites, non-profit organizations, municipal corporations, or other selected users. The subsurface rights go to the regional corporation. If the entitlement of all the villages in the State does not total 22 million acres, the remaining acreage 542 is divided amongst the regions on a population basis. The regional corporations then allocate these acres to their village corporations, based upon need, pop- ulation and historic uses. The villages then select where the acres are to be used within their village withdrawal or deficiency areas in order to complement their original entitlement selections. As in other village selections, the subsurface rights accrue to the regional corporations. The regional land selection of 16,000,000 acres (6.4 million hectares) for the whole state must be selected from lands designated as: a) village withdrawal lands remaining of b) regional deficiency land if in sufficient village withdrawal remains. This land is selected by the regional corporation. Each region's entitlement is based on the size of the region's area with deductions for previous village selection. Land is selected on the basis of the regional corpo- ration's management decisions for the future of the region. This selection must be completed by December 18, 1975 and will result in the land being used according to the regional corporation's plan for the future of the region. Selection from unreserved and unappropriated public lands outside the withdrawal areas of 1,500,000 (600,000 hectares) for the whole state must be selected for the preservation of historical places and cemetery sites and residence land for small non-village groups and individuals. Selection of the place of residence for non-village individuals must be completed by December 18, 1973. This will result in the preservation of sites of importance to the region as well as residence land outside the established villages. Selection of any remaining lands to fulfill the 40 million acre (16.2 million hectares) entitlement of the Act must be selected from remaining withdrawal or deficiency lands. The regional corporation selects these lands based on regional enrollment. Through this section the entire 40 million acre entitlement is insured in accordance with the Act (Arctic Environ- mental Information and Data Center 1972). The land from which Native village corporations and regional corporations can select their entitlement totals 1,736,707 hectares. Approximately 1,358,338 hectares of this are classified as village withdrawals, 378,037 are classified as village deficiency withdrawals, and 332 as regional deficiency withdrawals. Under Sections 11, 12, and 14 of ANCSA the following villages are eligible to select land: 543 VILLAGE MAXIMUM LAND ALLOWED (hectares) Kodiak Island: Afognak - 27,972 Akhiok - 27,297 Kaguyak - 27,972 Karluk - 27,972 Kodiak - 9,324 Larsen Bay - 37,297 Old Harbor - 46,621 Ouzinkie - 37,297 Port Lions - 46,621 Uyak - 27,972 Aleutian Islands: Belkovski - 27,972 Chignik - 27,972 Chignik Lagoon =. 27,972 Chignik Lake - 37,297 False Pass - 27,972 Ivanof Bay - 27,972 King Cove - 46,621 Nelson Lagoon - 27,972 Pavlof Harbor - 27,972 Perryville - 27,972 Sand Point - 46,621 Squaw Harbor - 27,972 Unga - 27,972 Currently Koniag, Inc. is trying to obtain eligibility for the following additional villages on Kodiak Island:! Aiaktalik Anton Larsen Ayakulik Bell's Flats Kitoi Litnik Port Williams (Shuyak) Uganik Woody Island lxarl Armstrong, Lands Specialist, Koniag, Inc. Kodiak, October 1973. Personal communication. 544 Land use constraints on land withdrawn for Native selections can be seen in Table 98. After December 18, 1975 most lands not selected by the native corporations will be classified by the Secretary of the Interior to protect the public interest. The state will have selection rights on most of these lands. Miscellaneous Land Withdrawals: Other land having temporary status includes the 10,280 hectare Karuluk Indian Reserve located on Western Kodiak Island. It is the only Indian reserve in the Western Gulf of Alaska region and was revoked under Sec. 19 of ANCSA. However, its lands are being held intact until December 18, 1973, when the village corporation of Karluk is to exercise the option provided under Sec. 19 of ANCSA. The corporation may then choose either to retain both surface and subsurface rights to the entire reservation and give up any other land selection opportunities and monies as provided in the Act, or to select its entitlement (27,972 hectares) to surface rights only, and be eligible for all the other benefits of the Act. Land use constraints in effect until December 18, 1973 can be seen in Table 98. If the Karluk village corporation decides to retain ownership of both surface and subsurface rights, the land uses will be immediately determined by the village corporation. If the corporation elects to retain surface rights, land use constraints will be similar to those on other lands withdrawn for Native selections. Land designated under Section 17(d)(1) of ANSCA and Public Land Order 5180 and 5186 were withdrawn to determine their proper classification in order to protect the public interest. There are 353,990 hectares of these public interest areas. Some of these lands are subject to immediate selection by the State of Alaska.! Village and regional corporations may select any of these lands that are encompassed by village withdrawal areas or village and regional deficiency withdrawals. The State of Alaska may select D-2 lands only after December 18, 1974. These selections may be made only from areas now covered by the 25 township Native withdrawals.3 Wildlife refuge replacement lands were withdrawn to serve as possible replacements for existing refuge lands that are selected by the Native village corporations. There are 183,185 hectares in this classification. All are located adjacent to the Izembeck National Wildlife Refuge. The Secretary of the Interior is under no time constraints to rescind or reclassify either Section 17(d)(1) or wildlife replacement lands. Land use constraints imposed on these lands are given in Table 98. lu.s. Public Land Order 5186. 2U.S. Pl. 92-203, Sec. 17 (d)(1). 3Esther C. Wunnicke, co-counsel, Joint Federal-State Land Use Planning Commission, November 1973. Personal communication. 545 References Cited Alaska Consultants 1970. City of Sand Point Comprehensive Plan (prepared for the Alaska State Housing Authority). Anchorage, 1973. Alaska Crop and Livestock Reporting Service 1972. "Alaska Farm Facts." Alaska Agriculture. Palmer. May. Alaska Crop and Livestock Reporting Service 1973. Alaska Agricultural Statistics. Palmer. Alaska Department of Administration 1971. Salary Schedules. Division of Personnel. Juneau. Alaska Department of Administration 1972. Survey of Salaries and Benefits, Housing and Food Costs and Salary Recommendations, Part III Housing and Food Costs. Division of Personnel. Juneau. Alaska Department of Economic Development 1972. Alaska Statistical Review. Juneau. Alaska Department of Economic Development 1973. The Alaskan Economy - 1971 and 1972. Juneau. Alaska Department of Education 1970. Annual Report 1969-70. Juneau. Alaska Department of Education 1973. Alaska Educational Directory 1973-74. Juneau. Alaska Department of Fish and Game. Various years. Alaska Catch and Production - Commercial Fisheries Statistics. Juneau. Alaska Department of Fish and Game 1973a. Commercial Operators 1972. Juneau. Alaska Department of Fish and Game 1973b. Kodiak Area Management Report, 1972 (mimeo). Juneau. Alaska Department of Fish and Game 1973c. "Kodiak; Shellfish Capital of the World." Fish and Game, July-August. Juneau. Alaska Department of Health and Social Services. Various dates. October Report. Division of Family and Children Services. (mimeo) Juneau. Alaska Department of Highways 1972. Five Year Highway Construction Program - 1972. Juneau. Alaska Department of Labor. Various dates. Alaska Workforce Estimates. Division of Employment Security. Juneau. 546 Alaska Department of Labor 1960-1972. Statistical Quarterly. Division of Employment Security. Juneau. Alaska Department of Labor 1972. Current Population Estimates. Juneau. Alaska Department of Natural Resources 1972. Alaska Outdoor Recreation Historic Preservation. Division of Parks. Juneau. Alaska Department of Public Works 1972. Annual Report - 1971. Juneau. Alaska Legislative Council 1972. Transportation in Rural Alaska. Legislative Affairs Agency. Juneau. Alaska State Housing Authority 1968. King Cove, Alaska Comprehensive Development Plan. Anchorage. Arctic Environmental Information and Data Center 1972. Village and Regional Land Selections. (mimeo) University of Alaska, Anchorage. Babb, James D., Jr. 1972. "Age and Sex Characteristics of Alaska's Population." Alaska Review of Business and Economic Conditions, Vol. IX No. 1. Institute of Social, Economic and Government Research, University of Alaska, Fairbanks. Buck, Eugene H. 1973. National Patterns and Trends of Fishery Development in the North Pacific. Arctic Environmental Information and Data Center, University of Alaska, Anchorage. Chaffin, Yule 1967. Koniag to King Crab. Chaffin, Inc. Elridge, Peter 1972. "The King Crab Fisheries in the Gulf of Alaska." In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald Rosenberg (ed). Institute of Marine Sciences, University of Alaska, Fairbanks. Evans, Ron and Peggy Raybeck, comps. 1973. "Age and Race by Sex Characteristics of Alaska's Village Population," Alaska Review of Business and Economic Conditions, Vol. X, No. 2. Institute of Social, Economic and Government Research, University of Alaska, Fairbanks. Federal Field Committee for Develoment Planning in Alaska 1968. Alaska Natives and the Land. Superintendent of Documents, Washington, D.C. Federal Field Committee for Development Planning in Alaska 1971. Community Inventory, Alaska. Anchorage. Federal Water Quality Administration 1970. Kodiak Oil Pollution Incident, February-March 1970. (mimeo.). Governor's Study Group on Limited Entry 1973. A Limited Entry Program for Alaska's Fisheries. Juneau. Hickok, David M. and Esther C. Wunnicke 1970. Observations on Marine Affairs in Alaska. (Prepared for the Alaska Commission for Ocean Advances through Science and Technology by the Federal Field Committee for Development Planning in Alaska). Anchorage. International Pacific Halibut Commission 1973. Annual Report - 1972. Seattle. Jones, Dorothy 1973. Patterns of Village Growth and Decline in the Aleutians, ISEGR Occasional Paper No. 11. Institute of Social, Economic and Government Research, University of Alaska, Fairbanks. Kodiak Chamber of Commerce 1973. Information leaflet. Kodiak Island Borough 1973. Overall Economic Development Program, Annual Progress Report. Kodiak. League of Women Voters, Fairbanks North Star Borough 1973. Alaska's Land: Which Direction? Fairbanks. Main, Lafrentz and Co. 1973. Kodiak Island Borough Report on Examination, Year Ended June 30, 1973 (audit on budget). Anchorage. Marsh, Charles F. 1971. Food Prices in Alaska with Supplemental Cost of Living Data ... 1960 to 1970. Institute of Agricultural Sciences and Cooperative Extension Service, University of Alaska, Fairbanks. Reuben H. Donnelley Corp., 1973. Official Airline Guide (North American Edition). Oak Brook, Illinois. Rogers, George W. 1971. Alaska Native Population Trends and Vital Statistics, 1950-1985, ISEGR Research Note. Institute of Social, Economic and Government Research, Fairbanks. Rogers, George W. 1972. A Study of the Socio-Economic Impact of Changes in the Harvesting Labor Force in the Alaska Salmon Industry. Institute of Social, Economic and Government Research, University of Alaska, (mimeo. ) Fairbanks. Rogers, George W. and Richard Cooley 1963. Alaska's Population and Economy, Volume I- Analysis, Economic Series Publication No. 1, Vol. I, II. Institute of Social, Economic and Government Research, University of Alaska, Fairbanks. Stephens, Christopher 1973. Alaska Red Meat Market - An Analysis. M.A. thesis, University of Alaska, Fairbanks. 548 Sullivan, James and William Rose, comps. 1970. Alaska School Enrollments, ISEGR Report NO. 24. Institute of Social, Economic and Government Research, University of Alaska, Fairbanks. Tryck, Nyman and Hayes, 1968. Kodiak Island Borough Comprehensive Plan U.S. U.S. U.S. U.S. U.S. U.S. U.S. U.S. 1978-1999, Part I. (Prepared for the Alaska State Housing Authority). Anchorage. Bureau of the Census 1950. 1950 Census of Population, Alaska. Department of Commerce, Washington, D. C. Bureau of the Census 1960. U.S. 1960 Census of Population, Alaska. Department of Commerce, Washington, D. C. Bureau of the Census 1970a. U.S. 1970 Census of Population, United States Summary. Department of Commerce, Washington, D. C. Bureau of the Census 1970b. U.S. 1970 Census of Population, Alaska. United States Summary. Department of Commerce, Washington, D. C. - Bureau of the Census 1970c. U.S. 1970 Census of Housing, United States Summary. Department of Commerce, Washington, D. C. Bureau of the Census 1970d. U.S. 1970 Census of Housing, Alaska. Department of Commerce, Washington, D. C. Bureau of Sport Fisheries and Wildlife 1972. Kodiak National Wildlife Refuge - Wilderness Study Report. (preliminary draft) Department of the Interior. Coast and Geodetic Survey. United States Coast Pilot 9 - Pacific and Arctic Coasts, Alaska, Seventh (1964) Edition, including 1966 and 1971 Supplement. Department of Commerce, Washington, D. C. Coast Guard 1973. Welcome to Kodiak. Kodiak Coast Guard Base. (mimeo). Department of Commerce 1973. State of Alaska Guide Register. Division of Occupational Licensing. Juneau. : Department of Transportation 1972. Airport Activity Statistics. Federal Aviation Agency, Civil Aeronatics Board. Forest Service, Alaska Region 1970. Chugach National Forest Map, Department of Agriculture. Forest Service, Alaska Region 1973. Proposed Timber Harvest in the Perenosa Timber Sale. Draft environmental statement, Depart- ment of Agriculture. Geological Survey 1943. Cold Bay Quadrangle. Reconnaissance Series Scale 1:250,000, map. 549 U.S. Office of Economic Opportunity 1971. Federal Outlays in Alaska. (compiled for the Executive Office of the President, fiscal year 1971). U.S. Public Health Service 1969. Community Survey of Ivanoff Bay, 1969. (mimeo). Weise, John, 1971. "Alaska's Shrimp Industry," Alaska Review of Business and Economic Conditions (Vol. VIII, No. 2.) Institute of Social, Economic and Government Research. University of Alaska, Fairbanks. Wolf Management Service 1965. Kodiak Alaska - Its Resources, Its Economy and Its Potential. Chicago, Illinois. 550 IX. EFFECTS OF THE ENVIRONMENT ON RESOURCE USE GEOMORPHOLOGY The rugged, mountainous terrain and the generally poor weather conditions (see below) make flying extremely hazardous in the study area. Most places level enough for landing strips are surrounded by mountains. This dangerous situation is emphasized by the recent crash of a U.S. Air Force cargo plane near Cold Bay in September 1973. Parts of the offshore area are extremely hazardous for navigation; navigation is especially difficult around islands where there are many reefs and skerries. Most of the nearshore areas are fairly well charted, but much of the area further offshore is only lightly charted (Figure 5). Particularly dangerous in this offshore area are the banks and shoals along the outer shelf edge. These areas are not well charted and many are quite shallow, some even approach sea level in a few places. This area was a zone of intense uplift during the 1964 earthquake (Figure 63) and any bathymetry prior to that time could have been significantly changed by the uplift. Many bays and fiords in the area offer natural harbors for refuge from storms. The coastline is best described in the Coastal Pilot (Coast and Geodetic Survey 1964), plus an interesting personal description of the coast by Logan (19707). CLIMATE-OCEANOGRAPHY The severe weather and wave conditions found throughout the region make human activities difficult at times. Sustained winds, especially those associated with the severe winter storms traveling northeastward along the storm track, will frequently range from 50 to 75 knots and occassionally will reach over 100 knots above open water. Aircraft operations, especially landings and takeoffs, can be extremely hazardous during these storms. In addition, these wind velocities are strong enough to damage offshore structures if they are not properly designed. Strong winds in the vicinity of mountains can also cause severe turbulence that is hazardous to aircraft and buildings. Williwaws, short but violent local storms, can develop and adversely affect both land and ocean based installations. Generally, wind speeds over land are not as strong as over water, but may still damage structures. Storms often move slowly or remain stationary for several days; this creates substantial wave activity. Theoretically, waves up to 18 m. high could be generated, but generally, waves greater than 9 m. have not been observed. The steep shape of the forming waves is more of an impediment to ship operations than is the actual wave height. Tidal currents in the area are appreciable but generally not extreme like they are in Cook Inlet to the north. Locally, in restricted passes or passages, currents can reach significant velocities. Tidal ranges are fairly great in the northern part of the study area. Temperatures in the area are not extreme and do not hamper outdoor activities to any extent, although occasionally the cold northerly winds cause temperatures to drop the chill factor to -30 degrees F (-34 degrees C). Sea temperature varies about 16 degrees F (9 degrees C) through the year, and may drop to the mid-30's during the coldest months. In winter a person could perish with as little as 30 minutes exposure in the water (Figure 16, Table 8). During periods of critically low temperatures, condensation and spray can form ice on the superstructure of ships, oil platforms, and onshore structures. Icing of aircraft also becomes a problem. Ceiling and visibility in the area are extremely low much of the time (Table 7) and can severely restrict the use of aircraft. Areas can be "socked in'' for extended periods. The scarcity of alternative landing facilities in the area makes this an especially critical problem. Dense fog, especially during the summer months, also poses a serious hazard and can hamper both onshore and offshore surface operations. Enroute aircraft are affected by cloud cover, heights of cloud bases and tops, visibility, turbulence, icing and flight level winds. All will vary with the season in amount or intensity. No climatological data for these parameters exist for enroute conditions. It is advisable to request a weather briefing from an FAA Flight Service Station or a National Weather Service Office. HYDROLOGY Providing an adequate water supply for onshore facilities may be another problem. Kodiak experienced a severe water shortage last year, and several canneries had to shut down operations. This was caused by an unusually low runoff which was unable to keep the present reservoir filled. The city is now building a larger reservoir. Since the groundwater potential of the region is fairly poor, furnishing a water supply system for any sizable, onshore facility probably would involve building a local dam and reservoir. This might, in turn, damage such things as salmon spawning areas unless corrective measures were taken (such as a fish ladder). 551 GEOLOGY Seismicity The study area lies within an active seismic belt and is extremely susceptible to earthquake damage. The area is included in seismic risk zone 3, areas susceptible to earthquakes between magnitudes 6.0 and 8.8 and areas where major structural damage from those earthquakes could occur. As seen in Figure 176 many earthquakes with magnitudes greater than 6.0 have occurred in the study area this century. The area between Kodiak and Unimak Island is characterized by a "seismic gap,"' an area that has not experienced a large earthquake (7.0) in the past several years (since 1938). Time-space studies of large earthquakes along the Aleutian trench and vicinity suggest that this seismic gap or block may experience a large earthquake in the near future, perhaps sometime between 1974 and 1980 (Kelleher 1970). Damage due to earthquakes can be severe and can be caused by a variety of factors. The primary effects are due to direct seismic vibration of the ground, which causes ground breakage, mud or sand emission from cracks, ground lurching and shaking, and local subsidence of unconsolidated sediments. Structural damage is the main result of this ground motion. Secondary effects caused by earthquakes include fires, seismic sea waves, and both subaerial and submarine landslides. Large scale tectonic changes, such as uplift and subsidence, can also have widespread effects. In addition, earthquakes can cause local and regional effects on the biology, hydrology, atmosphere, and magnetic field. The great 1964 Alaska earthquake illustrates the potential impact on the area. Late in the afternoon of March 27, 1964, one of the greatest geotectonic events of our time occurred in Southern Alaska. Half of Alaska was rocked and jarred by the most violent earthquake to occur in North America this century. Few earthquakes in history have been this large. Its magnitude has been computed by various observers to range from 8.3 to 8.75 on the Richter Scale. The epicenter of the earthquake was located at the head of Prince William Sound on the south flank of the Chugach Mountains about 130 km. east-southeast of Anchorage. The hypocenter, or point of origin, was at a depth of 20-50 km. The duration of the earthquake was only estimated because of the lack of instrumentation; observers calculated the duration of the shock to be between three and four minutes. 552 7ON 170 E 180 170 W 160 150 140 ARCTIC | OCEAN EXPLANATION °° Magnitude ° ° 6.3-5.9 A. 0° © © 6,0-6.9 ON. ° © 7.0-7.7 aa O 7.75-8.5 ow Filled circles aA =hypocenter>50 KM wo ° ALE o° 4% UTian 'SLan Ds 2 R, lo aM, Ar Seq Pn “eo ~ VOs/ ANDREANOF ISLANDS C0806 5 i: e Sie, 0 500 MILES ice ee ed ess Figure 176. Epicenters of Major Alaskan Earthquakes, 1898-1961 (from Hansen 1971). 554 This earthquake has become renowned for its long duration and great destructiveness. Thousands of people lost their homes, 114 people were killed, and the economy of the entire state was disrupted. Seismic seawaves swept the Pacific Ocean from the Gulf of Alaska to Antarctica. All these effects discussed above occurred during this earthquake. The earthquake also provided a great natural laboratory for studying the cause and effects of large earthquakes. Numerous investigations were made following the earthquake, and numerous publications followed reporting the results. Perhaps the most significant publication was a series of 8 volumes by the National Academy of Sciences. These volumes cover each of the following topics: Geology, Seismology and Geodesy, Hydrology, Biology, Oceanography and Coastal Engineering, Human Ecology, and Summary and Conclusions. The northern part of the study area around Kodiak Island was directly affected by the 1964 earthquake. Local subsidence of alluvial material plus numerous landslides and rockslides accompanied the shaking; large-scale tectonic movements also occurred. The axis of maximum subsidence trended northeast along central Kodiak Island, the line separating uplift from subsidence trended along southeast Kodiak, and the axis of maximum uplift trended offshore southeast of Kodiak (Figure 63). Widespread flooding occurred in areas of both tectonic and. compaction subsidence. Changes in the local hydrology were observed. The most devastating effect of the earthquake resulted from seismic sea waves that caused loss of life and wiped out several villages as well as downtown Kodiak. Two reports by Plafker and Kachadoorian (1966) and Kachadoorian and Plafker (1967) discuss in detail the effects of the earthquake in the Kodiak region. Tectonic movements of the sea floor would probably have the most significant effect on any oil operations in the study area. Areas of uplift could expose to near sea level portions of the sea floor, which then would become navigation hazards. Vertical movements along faults potentially could cause damage to pipelines laid across them; an especially vulnerable area would be the fault zone opposite the southeast coast of Kodiak Island. This zone contains many recent fault scarps, and any pipeline from the shelf edge to Kodiak would cross it. Pipelines and structures would have to compensate for vertical displacements of at least 3 m., the maximum movement observed during the 1964 earthquake. In addition, any wells drilled through near-surface faults, especially the ones flanking anticlinal structures on the shelf edge, would be vulnerable to damage. 555 Large scale displacements of the sea floor would probably cause seismic sea waves or tsunamis similar to the 1964 earthquake. Low- lying coastal areas, especially those that experience both tectonic and compaction subsidence, would be extremely susceptible to inundation by sea waves. Any new coastal facilities should be built on high ground. In addition, most ground damage and foundation failure during the 1964 earthquake occurred in areas of saturated, unconsolidated Quaternary. deposits or artificial fill, due to partial liquefaction and differential settlement. These factors also should be considered in the placement of any onshore petroleum facilities. Earthquake prediction is on the verge of becoming a practical reality (Scholz et al. 1973). This is largely due to the recent study of effects premonitory to earthquakes, such as coastal movements and anomalous changes in tilt, fluid pressure, electrical and magnetic fields, radon emmission, the frequency and occurrence of small local earthquakes, and the ratio of the number of small to large shocks. Most significant is the possible premonitory change in the ratio of the number of the seismic shear velocity (Scholz et al. 1973). It soon may be possible to predict large earthquakes in the study region more accurately. To this end, a detailed seismic net is being established in the Shumagin Island area (Figure 61). In addition, the U.S. Geological Survey is conducting fiedd studies in the area as part of an overall study of earthquake hazards in southern Alaska. The project is under the direction of George Plafker and field work in the Kodiak region was carried out during the 1973 season by Warren Coonrad. The objective of the overall project is to study and evaluate seismic risk in Alaska from tectonic displacement, seismic shaking, and secondary geologic effects. A more general goal is to gain insight into tectonic processes within the seismically active zones of Alaska, especially southcentral Alaska. Field work in the Kodiak Island area concentrated upon active faults and displaced shorelines. Volcanism As mentioned in an earlier section, the study area includes a chain of active and potentially active volcanoes extending along the coast of the Alaska Peninsula. All of these volcanoes are potentially hazardous to nearby activites, because of both the processes and secondary effects. These volcanoes tend to erupt andesitic lavas and ejecta which are more viscous than normal oceanic lavas. Eruptions associated with these andesitic volcanoes tend to be more violent and explosive and, therefore, more hazardous. Primary eruptive phenomena include: 1. Krakatoan eruptions - large violent explosions involving a voluminous outpouring of ejecta and destruction of large portions of the volcano summit, mainly because of collapse. 556 2. Nuee ardente (ash flow, "glowing cloud") - clouds of incandescent gases and ejecta that flow swiftly downslope from the volcano summit. They can flow away from the volcano for many miles and potentially are extremely hazardous and destructive of anything in their paths. 3. Pyroclastic eruptions - pyroclastic ejecta can range in size from blocks and bombs to fine-grained ash, and is the main type of material forming andesitic volcano cones. Deposition of significant thicknesses of ash can oocur 160 km. away from the volcano depending on the direction and magnitude of the wind. 4. Turbulent ash clouds and columns - bursts of gas, steam and ash that rise vertically to heights of 15,000 to 30,000 meters, can be especially hazardous to aircraft in the area. 5. Lava flows - are generally of minor importance in the formation of andesitic volcanic centers. Due to the viscous nature of the lava, the flows generally don't extend far from the eruptive center before congealing. In addition to the primary eruptive phenomena, there are various secondary phenomena associated with eruptions that could be hazardous: 1. Volcanic mudflows and landslides - mixtures of ejecta and meltwater that flow off the flank of volcanoes after eruption 2. Flash floods - caused by the sudden melt of snow and ice following an eruption, or possibly due to the breakup of ice-dammed lakes 3. Lightning discharges - often associated with volcanic eruptions 4. Corrosive rains - caused by acidic volcanic gases that mix with precipitation 5. Earthquakes - caused by volcanic processes within the plumbing system of the volcano 6. Seawaves - caused by submarine eruptions or by large mudflows or nuee ardentes flowing into the ocean Examples of almost all of these eruptive phenomena have occurred in the study area or in nearby areas during historic times. The 1912 Katmai eruption is an excellent example of a large violent explosion; it ranks as one of the greatest eruptions in recorded history. More than 24 cu. km. of material was ejected and produced a thick blanket of ash east of Katmai. The ash blanket was 0.3 m. (one foot) on Kodiak Island, over 100 miles away. This eruption also produced a massive nuee ardente that filled a valley northwest of Katmai and formed the Valley of Ten Thousand Smokes. Large earthquakes felt locally also were associated with this eruption. A detailed summary of the volcanic activity of the Katmai region is contained in a book soon to be published by the University of Washington Press (Forbes, In Press). The eruption of Augustine Volcano in 1883 is another example of a violent eruption that created a large summit crater. Associated with this eruption was a massive mud slide down the north flank of the mountain. The slide apparently reached the sea and caused a large seawave, which struck English Bay with a maximum amplitude of 30 ft. Fortunately the tide was low and there was no loss of life. This volcano is presently building another lava dome within the crater and could erupt with another violent explosion at any time. Although it is located just north of the study area, its marine location and its proximity to transportation routes still make it hazardous to any activities in the area. There are many other examples of how volcanic activity can disrupt man's activity in the region. The Katmai ashfall caused numerous problems on Kodiak and caused "acid rains" in Seward and Cordova. In 1953, Mt. Spurr showered ash on Anchorage, which damaged aircraft and necessitated an expensive cleanup. The eruption produced a mushroom cloud that rose to a height of approximately 20,000 m. in 40 minutes, a good example of a violent, turbulent ash cloud eruption. The 1966 eruption of Mt. Redoubt caused a massive mudflow plus a flash flood that threatened the pipeline terminal at Drift River. A seismic party in the Drift River Valley had to be evacuated. Pavlof Volcano is currently erupting (November 1973) with a cloud up to 6,000 m., and lava flowing down the northeast side. This volcano could be potentially disruptive of activities at Cold Bay, only 50 km. away. ; Like earthquakes, volcanic prediction is on the verge of becoming a practical reality. Premonitory effects include increases in microseismic activity, tilting of the inflating volcano, increased fumarolic activity, changes in the local magnetic and telluric field, and even changes in the ionosphere-reflecting layer. Perhaps the most promising predictive tool available today is the monitoring of microearthquakes. Microearthquakes apparently increase in frequency prior to eruptions, a response to the buildup of cumulative seismic strain associated with resurgent growth of a lava dome. This tool is being used extensive by Japanese scientists, but it is only just beginning to be used in this country. 557 558 Augustine Island is one of the few places where microearth- quakes are now being studied. The University of Alaska Geophysical Institute has been carrying out a detailed geophysical study of the volcano since 1970. This project is currently under the direction of Dr. Jurgen Kienle. So far the research has demonstrated a high level of recurrent microearthquake swarm activity. A buildup of activity was recorded in October, 1971, just prior to a minor eruption. Five seismic stations are now continuously monitoring the microearthquake activity. Additional geophysical monitoring of the volcano, such as tilt studies and magnetic studies, will be carried out as more funds become available for the project. Augustine is presently the only Alaska volcano under continuous surveillance. Scientists believe that there is a real need to expand research of Alaska volcanoes, and it is hoped that seismic stations can eventually be placed on all volcanoes in the vicinity of man's activity. In addition to geophysical studies, satellite surveillance and monitoring capabilities should be initiated. An integrated volcano monitoring and warning system for the entire Cook Inlet-Alaska Peninsula area would be the desired end result. BIOLOGY Man's activities can be affected by the biological environment in many ways. Foremost is the presence of mosquitoes and flies. Because of adverse effects on natural ecosystems, the State Department of Environmental Conservation has regulations governing use of insecticides. Permits for their use are required on a project by project basis.1 Less common, but more serious is the behavior of cliff nesting birds in response to aircraft. When an aircraft approaches, the birds commonly dive from their nests into the ocean often in dense swarms. Aircraft flying close to a cliff below nest level can be in considerable danger of hitting these relatively large birds. Helicopter rotor blades are particularly vulnerable. 1. Kyle Cherry, Alaska Department of Environmental Conservation, Anchorage, Alaska. Personal communication. Both black and brown bears are a valuable resource, but can be a nuisance around a camp. Carelessly handled food and garbage can attract bears and lead to their eventual destruction. Brown bears, with low populations and relatively low reproductive potential, are particularly vulnerable and can be easily eliminated from an area. Bears are dangerous when they become accustomed to humans. 559 Literature Cited Coast and Geodetic Survey. 1964. United States Coast Pilot 9, Pacific and Arctic Coasts, Alaska, Cape Spencer to Beaufort Sea. U.S. Department of Commerce. Federal Field Committee. 1971. Economic Outline for Alaska. Anchorage, Alaska. Forbes, R. B. In Press. The Volcanoes of Katmai. University of Washington Press. Seattle, Washington. Hansen, W. R., and E. B. Eckel. 1971. "Setting and Effects of the Earthquake.'' In: The Great Alaska Earthquake of 1964, Geology. Part A. pp. 5-43. National Academy of Sciences. Washington, D.C. Kachadoorian, R., and G. Plafker. 1967. Effects of the Earthquake of March 27, 1964 on the Communities of Kodiak and Nearby Islands. U.S. Geol. Survey Prof. Paper 542-F. 41 pp. Kelleher, J. A. 1970. "Space-Time Seismicity of the Alaska-Aleutian Seismic Zone." J. Geophysical Res. 75(29):5745-5756. Logan, B. J. 1970? Report on Alaskan Ports. Personal Report. 145 pp. Plafker, G., and R. Kachadoorian. 1966. Geologic Effects of the March 1964 Earthquake and Associated Seismic Sea Waves on Kodiak and Nearby Islands. U.S. Geol. Survey Prof. Paper 543-D. 46 pp. Scholz, C. H., L. R. Sykes, and Y. P. Aggarwal. 1973. "Earthquake Prediction: A Physical Basis." Science 181 (4102) :803-810. 560 561 X. IMPACT AND CONFLICTS OF RESOURCE USE POLLUTION Past and Present Sources Waste disposal is a problem in the city of Kodiak, where 16 pro- cessing plants, plus the city, have been dumping untreated wastes into waters adjacent to the community. The U.S. Army Corps of Engineers (1973) reports that these accumulated wastes are responsible for de- pressed oxygen levels in the harbor water and for the production of hydro- gen sulfide gas. The Environmental Protection Agency (1971) believes that these gas emissions and their tendency to cause algal mats to rise to the surface are detrimental to the ecological balance of the area. Kodiak is proceeding with a plan proposed by Tryck, Nyman, and Hayes (1971) to solve the city's problems at the forecasted 1990 popula- tion level. Industrial wastes from the processing plants will be screened and the residues processed into protein concentrate for animal food. Screens are scheduled to be installed by mid-February 1974.1 Domestic wastes will be collected by a separate system, treated, and discharged into Woody Island Channel. Kodiak has received a grant from the Environmental Protection Agency and construction is scheduled to begin soon. 2 The U.S. Coast Guard station at Kodiak will be served by a system that will separate storm and sanitary sewers. This system is presently in the design stage and should be completed within several years.5 Sewage has been traditionally dumped into the nearest convenient water body in most communities in the study area. The Environmental Protection Agency, U.S. Public Health Service, and the Alaska Department of Environmental Conservation are developing plans to control the problem. 1. Bill Lamoreaux, Alaska Operations Office, Environmental Protection Agency, Anchorage. Personal communication. 2. Stanley Brust, Alaska Operations Office, Environmental Protection Agency, Anchorage. 3. W.G. Colman, Chief, Engineering Branch, U.S. Coast Guard, Kodiak, per- sonal communication. 562 The frequency of oil pollution incidents during development of the Cook Inlet oil and gas fields was estimated using 47 randomly selected aerial surveillance flights conducted during the height of development operations--June 1966 to April 1968 (Evans 1969). These flights were not made in response to any reported spills, but were merely routine patrols. Nine significant spills were discovered containing dark ropy masses of oil at least 0.3 sq. km. in area or 0.8 km. in length. Seven of the nine spills were considerably larger. These observations suggest that during development of offshore oil fields, significant amounts of oil can be found on the water approximately 20 percent of the time. Small patches of irridescent sheen were found on most flights (Evans 1969). No in-depth studies of possible damage to the ecosystem were con- ducted during development of the Cook Inlet fields. The most serious known damage involved oil from an unknown source, which killed an esti- mated 1,800 to 2,000 sea ducks (Evans 1969). Subsequent to development of the Cook Inlet oil and gas fields, the National Environmental Policy Act of 1969 has been enacted. The effectiveness of this legislation on future offshore operations in Alaskan waters has yet to be demonstrated. Shipping operations can result in chronic spills in ports. The U.S. Army Corps of Engineers (1973) discusses the study conducted by Speyer and Tolkoff (1971) in Woman's Bay near Kodiak, an area where Navy and Coast Guard ships had been moored and fueled for about 30 years. This study concluded that the oil and fuel accumulated from years of seepage, tank cleaning, deballasting, and from normal shipping operations had made the soft muddy bottom in the vicinity of the Coast Guard pier rela- tively barren of marine flora and fauna, as compared to other areas within Woman's Bay. Future Sources Experience in Cook Inlet indicates that normal shipping can be an important source of accidental spills, either from ship collisions or human error in loading operations (U.S. Department of Interior 1970b). All of the larger spills resulted from these causes. Thus, even without development of petroleum resources in the Gulf of Alaska, there probably will be an increase of oil pollution incidents, if the current steady growth of ship traffic in the study area is maintained. A high percentage of this traffic handles petroleum products. Production of oil from the Gulf of Alaska outer continental shelf also would increase the activity. Some information about the effects of oil production in the Gulf can be gained from experience in Cook Inlet, 563 The Environmental Protection Agency is instituting a discharge permit system (Environmental Protection Agency 1973) that requires implementa- tion of sewage treatment standards by July 1, 1977. Application of these regulations to small settlements may be difficult because of high costs, but wastes from canneries and industrial operations probably will re- ceive adequate treatment by that date. Two major oil pollution incidents are known to have occurred recently in the study area. The Kodiak oil spill of 1970, presumably from a tanker discharging crude oil ballast, caused considerable damage to biotic re- sources as documented by the Federal Water Pollution Control Administration (U.S. Dept. of Interior 1970b). Effects from this incident were observed for nearly two months. Observers estimated that at least 1,600 kilometers of beachline were affected during the Kodiak incident. It also was esti- mated that an average of 16 dead birds was found per kilometer of beach inspected. At least 10,000 sea birds, mainly murres, auklets, guillemots, gulls, goldeneyes, and old squaws, were killed and washed up on beaches. No estimate was made of birds that might have been killed, but did not wash up on beaches. Numerous seals and sea lions were also reported to be covered by oil. No in-depth studies were conducted to appraise damage to lower life forms. Background studies recommended as a result of the investigation have not been carried out. In March 1972, a tanker grounding at Cold Bay in the Alaska Peninsula released portions of its cargo of diesel fuel and gasoline into Cold Bay, an important habitat for fish and wildlife including brant and emperor geese (U.S. Coast Guard 1973). The total amount of fuel lost was about 4,600 barrels. An in-depth appraisal of possible damage to marine organisms was not made. No significant damage was documented and winds kept the oil from areas where birds concentrated. During development of the Cook Inlet oil and gas fields, intermittent surveillance was conducted by several state and federal agencies (U.S. Dept. of the Interior 1970a). During the period between May 1966 and 1968, 122 oil pollution incidents were logged by various agencies conducting sur- veillance or responding to reports of spills. Only incidents were reported that involved "significant" amounts of oil with "significant" believed to be at least one barrel or more. Five spills were estimated to be more than 1,000 barrels, and several more were large spills of unestimated size. These spills resulted from pipeline breaks, tanker accidents, overfilling of tanks, leaks aboard platforms, and leaks and spills from various ap- purtenances aboard platforms and docks. Concentrations of mud sacks, pallet boards, and garbage also were observed frequently, but were not included in the list. The frequency of spills was greatest during the development phase of the Cook Inlet fields. By 1969, when most of the fields had been developed, the frequency of incidents dropped off significantly (U.S. Department of Interior 1970a). 1. Steven Provant, Chemist, U.S. Environmental Protection Agency, Alaska Operations Office. Personal communication. 564 although there are differences between the two projects. For example: 1. Operations in the Gulf would be in deeper water, but would not be subjected to such tidal currents as are found in the Inlet; 2. OCS operations would be regulated entirely by the federal govern- ment, while Cook Inlet development is regulated by both federal and state agencies; 3. Surveillance and enforcement of regulations would be more diffi- cult in the Gulf. Flying weather is adverse and major operating bases are distant. These difficulties are magnified significantly by the unreliability of forecasts; and 4. It is impossible to predict what special problems would be created by pipelines, loading facilities, or undersea completions due to un- certainties as to how oil would be produced and transported. It is not known whether platforms would be permanent or whether undersea completions would be utilized. Tankers could be loaded from offshore platforms or onshore facilities that would require feeder pipelines. Oil spills in a developing and producing oil field can result from a number of causes including blowouts, minor emissions from wells and drilling platforms, pipeline breaks, spills during loading and offloading of tankers, cleaning of ballast tanks and deballasting of tankers, ruptures of tankers and ruptures of storage tanks ashore. It is difficult to esti- mate the amount of oil which could be spilled from such operations. Kinney et al. (1970) estimate that 0.3 percent of the oil produced and handled in Cook Inlet ended up in the Inlet as effluents or spills. This is probably a conservative figure because it is based on estimated volumes cf reported spills. Neither the amount of oil lost in unreported spills nor the results of offshore tanker operations is included in this estimate. Hoult (1971) estimates that 0.1 of one percent of all oil transported or produced offshore is spilled on the sea. The U.S. Department of Interior (1972) includes a much lower estimate based on operations that would be comparable to the proposed trans-Alaska pipeline. Their estimates range from 0.007 percent forecasted for trans-Alaska pipeline oriented operations to 0.231 percent for worldwide operations, assuming non-use of "load on top" procedures on tankers.1! 1. "Load on top'"' is a procedure for management of "'slops" (residual oil remaining aboard a tanker after its cargo has been unloaded). The purpose is to reduce the amount of oil wasted overboard during de- ballasting operations. 565 The Federal Water Pollution Control Administration, in their assess- ment of the 1970 Kodiak pollution incident (U.S. Dept. of Interior 1970b), made an appraisal of the handling of slop oil and tank cleaning residues from tankers serving Cook Inlet. They estimate the volume of slop oil to be 3,000 barrels for a 250,000 barrel tanker. At that time, at least, the practice was to dump slop oil at sea. This would represent a spillage of slightly more than one percent of the oil handled. If industry esti- mates of 100 barrels of slop oil per tanker are accepted, the loss would be .033 percent of the oil handled, assuming the average capacity of a tanker to be 300,000 barrels. Little use was apparently made on on-shore deballasting facilities at that time. The U.S. Department of Interior (1970b) discusses in detail the pro- blems of washing cargo tanks and disposing of the oily residues either at sea or into shore-based ballast treatment facilities. Although it is im- possible to determine the exact amount of oil spilled into the ocean as a result of these operations, it is clear that it can amount to several hundred barrels per tanker per trip. Even under optimum conditions when all residual oil from tank cleaning and ballasting in cargo tanks is pumped ashore into ballast treatment facilities, a large amount of oil will still reach the sea. The best available treatment of cleaning water or ballast at Valdez will result in 10 parts per million of oil remaining in the ef- fluent from the facilities (U.S. Department of Interior 1972). This will amount to about 12 barrels of oil per day when the trans-Alaska pipeline is operating at full capacity. The exact composition of the oil remaining in the effluent is unknown, but it seems likely that the soluble fractions would remain to be discharged into the sea. Kinney et al. (1970) estimate that crude oil under Cook Inlet conditions biodegrades at a relatively rapid rate. It is impossible to predict the biodegradation rate at Valdez, however, and also to predict the effect of this oil prior to biodegradation. The potential for oil spills is somewhat greater if the possibilities of well blowouts are considered. Kash et al. (1973) state that OCS oper- ations during the period 1953 to 1971 resulted in one blowout per 500 holes drilled. They also cite a U.S. Geological Survey study (U.S. Department of Interior 1971) for the same period that listed 19 blowout accidents resulting in personal injury or damage to property and the environment. The U.S. Coast Guard! states that a policy established by presidential executive order will permit no further discharge of ballast at sea by U.S. registered tankers after 1980. If this policy becomes fully effective. it will do much to alleviate a large segment of the problem, but only where a large portion of the vessels are of U.S. registry. Regardless of which estimates of quantities of oil spilled are more accurate, it is clear that a considerable amount enters the sea. Appraisal of the impact from oil pollution requires knowledge of how much oil will 1. Lt. (jg.) David Binns, U.S. Coast Guard, Anchorage, Alaska. Personal communication. 567 be spilled, what kind of oil it is, where it will go, what resources will be affected, and how vulnerable these resources are to damage from the type of oil involved. Few data are available on which to base such appraisals. Fluids used when drilling for petroleum may be toxic. Falk and Lawrence (1973a) investigated drilling and sump fluids. Drilling fluids were found to be acutely toxic to fish, while sump fluids were highly variable and generally lower in toxicity. It seems doubtful that waste drilling fluids would reach toxic limits on the outer continental shelf of the Gulf of Alaska. Falk and Lawrence (1973a) recommended, however, that toxic materials used during a drilling operation should not be released into water bodies without meeting a prescribed toxicity limit. Flaring of gas from producing wells and burning off of sump pits has polluted the air in some areas (Evans et al. 1972). The Alaska Department of Environmental Conservation has established that operations on lands and waters under state jurisdiction must meet state air quality standards. These standards require that there be no significant degradation of air quality.1 Jurisdiction of the outer continental shelf by the Environmental Protection Agency under the Clean Air Act of 1970 is in doubt.2 This is presently being researched and a legal opinion is being sought. Natural Sources Many natural oil seeps are located along the Alaska Peninsula. Up to one-half barrel per day has been reported at one seep. The most active seeps are in the Kanatak area (Figure 52), where they are being studied and sampled by the U.S. Bureau of Mines. Preliminary results suggest significant oil is being introduced into surface waters, but it is not yet known how much is reaching the sea.> Hopefully, these Bureau of Mines studies along the Alaska Peninsula will continue and a quantitative eval- uation of the effect and amount of the oil reaching the marine environment through natural processes may be possible. Impact of Spilled Oil on Marine Biota Dean (1968) pointed out that medium molecular weight, aromatic hydrocarbons have greater solubility and are more soluble than the heavier elements in crude oil. These toxic soluble elements would evaporate slowly 1. Kyle Cherry, Alaska Department of Environmental Conservation, Anchorage. Personal communication. 2. Steven Provant, Chemist, Environmental Protection Agency, Anchorage. Personal communication. 3. Don Blasko, Mining Engineer, U.S. Bureau of Mines, Anchorage. Personal communication. 568 in the cold waters of the Western Gulf and their impact probably would last longer than in warm waters. The heavier tars and asphalts, while less soluble and less toxic, would not evaporate readily and would have more of a mechanical impact on such items as the feathers on birds. The Offshore 0il Task Group of Massachusetts Institute of Technology (1973) summarized the impacts of petroleum derivatives on various groups of marine organisms. They emphasized the significant toxicity of the soluble aromatic derivatives, and stressed the high variability of results from studies, depending on type of oil, circumstances, and method of study. They have classified impacts of hydrocarbons on organisms into five categories as follows: 1. Lethal toxicity, 2. Sub-lethal disruption of physiological or behavioral activities, 3. Effect of direct coating by oil, 4. Incorporation of hydrocarbons in organisms which cause tainting and/or accumulation of hydrocarbons in food chains, and 5. Changes in biological habitats. The first two categories refer to interference with cellular and sub- cellular processes. Effects of direct coating are the purely mechanical results that would occur from coating by any compound with physical charac- teristics similar to crude oil. Incorporation of hydrocarbons in organisms is important because of the potential for accumulation of carcinogens and tainting of human food supplies. These five categories are useful for ana- lysis of the effects of crude oil on biota. The Massachusetts Institute of Technology (1973) studies also provide a table interpreted from information of various other studies, which outlines the estimated toxicity ranges of certain general biotic groups. These estimated ranges of critical concentrations of crude oil in parts per million are as follows: Flora 104 - 10° Finfish 104 - 108 Larvae 102 = 10> Pelagic crustaceans 10° - 104 Gastropods 104 - 102 Bivalves 104 - 10 Benthic crustaceans 10° - 104 Other benthic invertebrates 10° - 104 These data from the Massachusetts Institute of Technology studies plus other available data have been used to compile a table attempting to show the susceptibility of various biotic groups to injury from crude oil (Table 101). This table lists the biotic groups found in the Western Gulf of Alaska area (column one), characterizes their habitat (column two), and gives their areas and seasons of peak abundance where known (columns three and four). Column five is an attempt to show the vulnerability of each TABLE 101/——SUSCEPTIBILITY OF MARINE ORGANISMS TO INJURY FROM CRUDE OIL oo SEASON OF PEAK VULNERABILITY TO DAMAGE BY CRUDE OIL HABITAT, AREAS OF PEAK ASUNDANCE _ _.. ABUNDANCE ail _—by month) . REMARKS sian Ene : E ee tle wl alwlsts[als loll at Marine Bacteria Pelagic ~ near surface Near surface ~ near productive bays 7 T! | Speculative & not highly probable Di 5 Wrimak area = peak populations eastwart Ton Oat ——- TF Phytoplankton - Diatoms predominant Pelagic = near coast,near surface suppressed by zooplankton grazing goat * | Zooplankton and Micronekton Telagic ~ follow phytoplankton and NE of Kodiak, SW of Shumagins Fane Shagest re | Speculative if mn peaks — a — "Marine Macrophytes Intertidal to 20 m. - eelgrass. Shallow lagoons - Cold Bay Growing passed T ‘Mortality low unless below.tow tide = 4 contamination severe = Intertidal fauna - including clams Intertidal or subtidal - clams on Kodiak, Unimak Yearlong ‘Vulnerability moderate Z sandy beaches _ . _ Clam Adults Intertidal or subtidal - Westward Yearlong Vainerabllity tow fa firm, wave-swept sand ~ 2 _ _ Clam Larvae Shallows Westward uly = November 5 Benthic Invertebrates Depth variable 10-250 m.) bottom, “Throughout ——Yeartong Tow probability of impact owi variable Tatas bays: passages spawn In shallows © abit King Grab > Adults ‘Summer concentration S. of Untmak, ‘Summer concentrations aw probability of Impact ‘on continental shelf, Cook Inlet to Unimak Pass S, and E. of Kodiak _ 7 ‘owing to habits King Grab - Spawning Shallows ~ subtidal to 100 m. ‘Same March = May ' King Crab = Immature Shallows, Same , ~ ~ i - ‘Semi-pelagic to benthic — “Same ft) ta - ‘Semi=pelagic,March - July King Crab - Larvae Tanner Crab - Adults Tanner Grab - Spawning ‘Abyssal plain to 2050 m, concentrate = ymmer ‘Shallows: E, Unimak, Unga Island = Paviot, Alitak Marmot-Chignik Bays, Cape Doug! me Tow probability of impact in deep water January - mid May Tanner Crab - Larvae ‘Semi=pelagic to benthic Same Dungeness Crab - Adults ‘Dungeness Grab - Spawning ‘hallows in summer, offshore in winter, firm sand, bays & ocean beaches, 46-96 m, or to 200 m, ‘ideline to 50 m, Samer concentration 8, of Trinity Island, +: yor Bay, S, coast of Unimak Same Dungeness Crab - Larvae ‘Semi-pelagic to benthic ‘Same —Shrliip W species) - Adulte ‘Shaimp ~ Spawning” Pelagic, concentrate 60-210 m bays, surface at night Bays and islands Rlltak, Uganik, Marmot Say, —ipe Douglas, SE Kodiak, & Afoanak, Stegovak, Paviof & Balboa Bays. Same ‘semi-pelagic, January - July ‘Summer - shallow’ ~ winter - deep _ Late fall = net ~~ Semi=pelagic, June - Dec ~Yeariong” ‘September ——Sirimp = Larvae Scallops - Adults ‘Semi=pelagic and benthic Throughout Gulf, 60-180 m. mud, Clay, gravel, sand Same Portlock Bank, Marmot Flats, Albatross Bank, Beaver to Paviof Bays “Tree swimming, February ~ July Yearlong Too deep for tainting Scallops - Larvae Planktonic June and July Pelagic Invertebrates - Squid Intertidal and near shore subtidal Band NSitkalidak, small quantities : Yeartong Fish - non-commercial (23 families) Varied habitats, surface to depth Varied ~~Yearlong Variable exposure Pollock - Adults Daily vertical movement, benthic 75-265 m. SE of Kodiak on Albatross Bank “TT Year tong ! 1 | : " 2 i | Pollock - Spawning Inshore shallows, eggs float near surface _ March - May | | | | = al so Pacific Cor BO=ZIS Hi, deep offshore waters In winter, "Sand TOT Kodiak, Shumagin Islands — —~— Tags March - fuly 1 +] os pelagic eggs eas i | | Black Cod 5-550 m, eggs and immatures at surface Dominant deep waters fish of peninsula. ‘Spawn February = March t | Bays, inshore most of life cycle, Spawn along shore Kodiak Bays and Shelikof Strait Spawn ‘pril = May Planktonic Concentrate 160-250 m, down to 450 m., 20-60 m, above rocky bottoms & canyons damage to kelp would Pacific Ocean Perch = Larvae ‘Demersat Flattish (excluding halibut) Halibut = Adults Halibut ~ Eggs and Larvae From less than 90 to more than 275 m. Spawning & Juvenile life unknown Most less than 90 m. to as deep as 1100 m. Midwater, drift to coastal shallows - = Eanes eee i aa ae reduce 5} habitat Some April - August H ‘Seasonal migrations LE. of Kodiak, 5. of — August 1 Deep water Unimak Canyon at ‘Strait | | | Mainly in eastern gulf t 7 Deep water Shelf and slope E. of Kodiak and T <a |. Deep water = Western Peninsula se | | Chirikof Island and NE of Kodiak, migratory rT T 1 Deep water Seward Gully, Trinity and Chirikof Islands Oo TABLE 101 (CONT) “SEASON OF PEAK VULNERABILITY TO DAMAGE BY CRUDE OIL BIOTIC GROUP HABITAT AREAS OF PEAK ABUNDANCE ____ ABUNDANCE by month) REMARKS JFMAMJJASOND Chinook Salmon - Adults — Shallow waters Chignik River and SW Kodiak july .T) ca T Toasibie Taselarence with pee cee - 7 eae» fa E 4 Hid dew migration Chinook Salmon = immatures 2-4 years, feed on small ish, Unknown Unknown Exposure uncertain ‘Coho Salmon = Adults Shallow waters Chignik aa T Mid July - September te a Migration ~~ Coho Salmon = immatures 1-2 years, feed on small fish, Unknown 7 al ea ‘Exposure uncertain crustaceans and aquid bar x ‘Chum Salmon ~ Adults ‘Abundant throughout, shallow waters Southeast Kodiak, Unimak, Migration NW of Shumagins te Chu Salmon = Tmmatures TS much ast years, eed on small ‘Tnknown Odsigait ky 7: crustaceans Pink Salmon - Adults Shallow waters Throughout Migration Pink Salmon - immatures 1,5 years, feed on planktonic Unknown | Outmigrant fry crustaceans _ Sockeye Salmon ~ Adults ‘Shallow waters ‘Abundant throughout Migration ~~" Sockeye Salmon = immatures 1-4 years in salt water. Unknown Smolts migrate at surface n ns fp ‘Unknown - general distribution General T Exposure uncertain 4n-shallow water ; Widely distributed offshore Karluk, Ayakulik and Chignik Rivers Exposure uncertain 2 early autumn, 4. | Black Brant Bays with eelgrass and other vegetation, Western peninsula Autumn, Spring No data to adequately assess sheen maritime feeders — —— 1 possible habitat damage ____ Emperor Geese Bays with eelgrass and other vegetation, Wester peninsula Autumn, Winter No data to adequately assess a1 8 maritime feeders at ‘ possible habitat dams Canada Geese Occasionally along coastal beaches Wot common ‘Autumn, Spring No data to adequately assess o 45 L | Possible habitat damage _ Paddle Ducks Bays, marshes, river mouths; Throughout, some yearlong ‘Autumn ~ Spring ' No data to adequately assess Diving Ducks Bays, shallows, protected waters; Throughout, some yearlong ~~ ~"Rutumn = Spring T ‘No data to adequately assess marine feeders ee, a possible habitat damage ‘Sea Ducks — Bays, estuaries, sometimes unprotected waters, Throughout, some yearlong Kutumn - Spring lo data to adequately assess (eiders, scoters, old squaws, harlequins) ___marine feeders ate bts 4. ssible habitat dama, Mergansers Bays, estuaries, Throughout, some yearlong Yearlong No data to adequately assess Ss ae marine feeders ss 3. Toons Bays, estuaries, marine feeders Throughout, some yearlong TI aad Winter | No data to adequately assess oo be } sible habitat dama; Grebes Bays, estuaries, marine feeders Throughout, some yearlong Fail and Winter fT No data to adequately assess a J — ai B He del possible habitat damage Albatross Surface of open ocean and Peninsula Sumner No data to adequately as a 7 occasionally tiderips a | possible habitat damage pss - ‘Tubenoses ‘Channels, passes, marine feeders Summer | T No data to adequately assess 7 (Shearwaters, fulmars, petrels) . eoaenom anit | j possible habitat damage Storm petrels Channels, passes, marine feeders Unknown Yearlong No data to adequately assess sible habitat dai Cormorants Coastal waters, dive for food Kodiak, Katmai Yearlong No data to adequately assess a Hh - sible habitat dama: Oystercatchers Intertidal ‘Alaska Peninsula and Kodiak Yearlong No data to adequately assess - sible habitat dama: Shorebirds Tntertidal of marine = mad Tats ‘Rlaska Peninsula and Kodiak Yearlong | No data to adequately assess 7 7 goth ssible habitat damay TJaegers Partly marine feeders on open waters ‘Alaska Peninsula and Kodiak Yearlong i No data to adequately assess = an sible habitat dama Galls and Terns Colonial nesters, partly marine feeders ‘Alaska Peninsula and Kodiak Glaucous-winged yearlong, 7 No data to adequately assess oars other summer ssible habitat dam ‘uke, murres, puffins Colonial nesters, totally marine feeders, ‘Rlaska Peninsula ond Kodiak Yearlong Ng Glen to Steaeaterr eveeas open waters edi ssible habitat dama Sea Otters Offshore reefs and kelp beds to 75 mm. depth Throughout Peak upping, Significant matting of fur April = June eliminates insulation teller Sea ion ‘Shallow Waters = Teed OF HSE TRFOUGHOUE Pupping in Jane | ‘Susceptibility appears slight i Northern Fur Seal Migrate about 150 miles offshore Not abundant Ty 7 Spring, Autumn 1%) | ‘Harbor Seal Water to 55m. - along bars, beaches Throughout oe ing late May, T loernicke _ early june | Toothed Whales Mostly offshore Unknown ‘Unknown T 7 ~ Mostly offshore ‘Unknown 2 Mostly summer Baleen Whales KEY TO EFFECTS [TTT] tethat toxicity ANY su-tethat cisruption of physiological or behavioral activities HHI trots of direct coating by of! Incorporation of hydrocarbons in organisms which Cause talnting and76r _accumulation of hydrocarbons in food chain. = — Changes in biological habitats OLS 571 group on a monthly basis in conformity with what is known of their life history. The category of impact is shown by the various bar pat- terns and the thickness of the bar indicates the estimated severity of the impact. A thin bar indicates a relatively low impact. A brief discussion of the susceptibility of various biotic groups follows: Marine Bacteria. Crude oil can be a food for certain marine bacteria (Kinney et al. 1969, Friede et al. 1972). Friede et al. (1972) suggest the possibility that some carcinogenic petroleum hydrocarbons could be con- centrated by bacteria and passed up the food chain. Phytoplankton. Although the Massachusetts Institute of Technology (1973) study reports that most zooplankton are filter-feeding crustaceans commonly found on the surface layers of coastal waters. They would, therefore, be subject to concentrations of oil-water emulsion. Friede et al. (1972) also point out that zooplanktonic filter feeders may also con- centrate carcinogenic compounds and pass them up the food chain or deposit them on the bottom as fecal pellets. Marine Macrophytes. Little is known about the effects of oil on marine macrophytes. Templeton (1972) stated that plants covered with oil produce new shoots unless the plant bases and surrounding soil have become contaminated. Individual seedlings and annuals rarely recover. Overall effects appear moderate. Intertidal fauna. The Massachusetts Institute of Technology (1973) report discussed findings from a number of studies that showed highly var- iable effects in this group. Susceptibility appears low in bivalve mol- luscs and periwinkles. Some groups, such as limpets, have a high suscept- ibility even at low concentrations of oil. Clams. Blumer et al. (1970) reported prolonged tainting of commercial clams resulting from a spill of fuel oil. Massachusetts Institute of Tech- nology (1973) treated larvae as a single group with relatively low resis- tance to the toxic effects of oil. Benthic Invertebrates. This group contains many species and forms living in various habitats. Most are in deep water and are assumed to be relatively invulnerable to oil. Egg and larval stages of many species, however, float on the surface or with the current and would be vulnerable (Wilber 1959). Crabs. Most adult crabs are deep water dwellers most of the year and are assumed to be relatively immune to damage. An exception is the Dungeness crab, which moves into shallow water during the summer. Also during spawning, crabs move into shallows and their exposure would increase at that time. Some heavier fractions of oil may sink to the bottom (Friede et al. 1972), where they remain for some time and could taint shellfish. Instances have been cited where shellfish were tainted and their marketability reduced 572 by exposure to even slight amounts of oil (Blumer et al. 1970, Wilber 1969). No such instance has been reported in Cook Inlet, where active crab fisheries have undoubtedly been exposed (Kinney et al. 1969, Evans et al. 1972). Larvae are assumed to be vulnerable during the period when they are pelagic. Immatures also probably would be vulnerable in shallow water. The National Marine Fisheries Service is conducting studies of the toxic effects of crude oil on tanner crab. Shrimp. All important species in the Western Gulf of Alaska prefer depths of 60 meters or deeper, except for a vertical migration toward the surface at night. At this time they would be more exposed and more vulnerable. Shrimp are most vulnerable in the larval stage. A catch of shrimp at Kodiak was reported to be coated with oil during the 1970 Kodiak oil spill incident (U.S. Department of Interior 1970b). The effect of sinking oils on the marketability of shrimp in the Gulf of Alaska is. not predictable, although shrimp could be tainted, particularly during their nocturnal migrations toward the surface. Scallops. Blumer et al. (1970) cite serious and long-lasting tainting of scallops as a result of a spill of fuel oil near West Falmouth, Mass. Since Gulf of Alaska scallops prefer depths greater than 60 meters, it seems unlikely that many of them would be affected. The planktonic larvae would be the most vulnerable stage for scallops. Pelagic invertebrates (squid). The Massachusetts Institute of Tech- nology (1973) report indicates pelagic crustaceans are moderately vulner- able to toxic effects of oil. Although the direct effects on squid are unknown, the oil presumably would affect their food supply. Fish, Noncommercial. Numerous species in the 23 families of non- commercial fish use various habitats ranging from the surface to consider- able depths. Most of the deep water species probably would be relatively immune to the effects of oil. A species living in shallow water, either permanently or during a shallow water stage of its life cycle, could be susceptible. Wilber (1969) quotes Gutsell (1921) as follows: "The eggs of sea fishes which do not seek fresh, brackish, or shore waters in which to spawn, differ from the eggs of all these and of fresh water species in that they are typically floating. In many cases, at least, the larvae for a time are also floating." Most of these species would thus be susceptible to damage from oil at some stage in their life cycle. Pollock, Pacific Cod, Blackcod, Pacific Ocean Perch, and Flatfish. These are all benthic forms living in deep water. They would be vulnerable only for short periods during spawning and in the larval stages. Herring. This shallow water species spends most of its life cycle near shore. Planktonic larvae and spawning adults are particularly sus- ceptible to toxic effects (Kunhold 1970). Their spawning activities would 573 also be affected if the kelp upon which they deposit their eggs were damaged. ' Salmon. Salmon adults are usually found in shallow habitats and could be affected by toxic elements in the water. Rice (1973) indicates that crude oil could upset salmon migration patterns by upsetting olfac- tory senses. If this were to unduly delay spawning migration, it might cause heavy losses to an entire year class. Smolt and fry migrate in shallow water and would be highly vulnerable. On the other hand, Rice (1973) also demonstrated that pink salmon fry avoid crude oil and might escape its effects if an alternative migration route were available. Trout, Char, and Steelhead. Not enough is known of the habits of these species to appraise their vulnerability. Presumably, they would be similar to salmon. Birds (general). Erickson (1963) and Aldrich (1970) describe the effects of oil on birds. Oil mats their feathers, reducing their buoyancy and insulation ability. Not only is the affected bird chilled and hindered in its mobility, but it may, while preening, injest some oil and be subject to its toxic qualities. Birds cannot recognize oil spills and avoid the danger. Birds whose habits bring them into closest contact with oil would be most susceptible. Black Brant and Emperor Geese. These are entirely marine feeders and would be highly vulnerable to losses from the mechanical effects of oil. Canada Geese and Puddle Ducks. To the extent that these species are less oriented to marine habitats, they would be less susceptible than emperor geese and brant. Diving Ducks. These species use the Western Gulf all year, but nest in fresh water. They would be most vulnerable in fall, winter, and early spring when they are on salt water. Sea Ducks. Except for nesting of scoters and the harlequin duck, sea ducks are entirely maritime in habit and would be vulnerable most of the year. The greatest numbers of these birds would be in the study area during spring and fall migration. Mergansers, Loons, and Grebes. These species nest on fresh water and winter on salt water. Their vulnerability would be similar to that of the diving ducks. Albatrosses. These birds are found in the Western Gulf in summer and could become trapped in any oil spilled in their feeding areas, parti- cularly in tide rips, where both spilled oil and birds tend to concentrate. 574 Tubenoses and Storm Petrels. These birds are totally marine feeders and would be highly susceptible to mortality from oil. Cormorants. Although the double-crested cormorants sometimes nests in fresh water, the two other cormorant species found in Alaska nest adjacent to marine habitats. In winter, all feed on exposed open water and could be caught in spilled oil during that period. Oystercatchers and Shorebirds. Birds of this group feed in the intertidal zone and could be affected by oil washing ashore. Jaegers. All the jaegers are associated with salt water, the para- sitic and pomarine jaeger more so than the long-tailed which nests inland. These birds do not feed on the water but could come in contact with food contaminated by oil. Their risk of exposure to oil is not as high as marine feeders. Gulls and terns. Birds of these groups that nest in colonies adjacent to salt water or that winter on salt water would be highly vulnerable to oil pollution. Auks, Murres, and Puffins. These birds spend all their time in or on salt water, except for periods they are engaged in nesting activities. This group is probably the most susceptible of all birds to losses from oil. Sea Otters. A sea otter depends on the cleanliness of its fur for warmth; consequently, anything that would mat its coat could be fatal. These animals spend their entire lives in salt water and could suffer high mortality from spilled oil. Other Marine Mammals. Straughan (1973)! reports no detectable damage to sea lions or elephant seals as a result of oiling during the Santa Barbara oil spill. Marine mammals of the Western Gulf of Alaska, with exception of sea otters, are assumed to be relatively resistant. Nursing young, however, might ingest toxic quantities and suffer damage. . Any loss of food supplies would be injurious to their populations. Special Circumstances. Species at the end of their range, already stressed by environmental conditions to which they are not well adapted, and species already harvested at or beyond their limit, could be parti- cularly vulnerable to any additional stress. Also, the use of chemical dispersants, a possible side effect of spilled oil, could be injurious to marine biota. Impact of Spilled Oil on Upland Biota A combination of storm and high tides could drive oil onto coastal marshes and beaches and could cause losses in such groups as puddle ducks and shorebirds. A large number of terrestrial mammals such as mink, 1 . Testimony by Dr. Dale Straughan before the Council of Environmental Quality, Anchorage, Alaska, September 26, 1973. 575 weasel, river otter, fix, muskrat, beaver, deer, bear, and otter could be exposed to oil, either directly or through their food supply. Impacts from such contact probably would not be severe, but damage to their habi- tat could be significant. Repeated severe contamination could eliminate important habitats. Chronic low level pollution could also alter habitats to a presently unknown degree. Other predominantly terrestrial species which occasionally contact salt water while feeding, such as eagles, falcons, and some hawks, also could be affected. OTHER IMPACTS OF INDUSTRY ACTIVITIES Impact _on Fisheries Presently, the only major industry in the study area is fishing, and conflicts with other industries are at a minimum. If another large industry, such as the petroleum industry, were to move into the area, certain impacts and conflicts with the fisheries might arise. Ships and boats needed to support petroleum activities would considerably increase traffic in the area, causing additional navigational hazards to the fishing fleet. This increased traffic also would increase competition for the already overcrowded port facilities, requiring construction of additional facilities. Kodiak harbor is the major port in the area and is already overcrowded, although a new small-boat harbor is planned for the near future. Petroleum development activities would take up space in the marine en- vironment now being used for fishing activities; this problem is discussed by the U.S. Department of the Interior (1973). Allowing for a navigation safety zone, it is estimated that each platform would occupy 8,000 to 20,000 sq. meters (two to five acres). Other obstructions, such as unburied pipelines, seafloor completions, wellhead stubs and debris, could be a hazard to trawling operations. Petroleum developments in various bays of the study area, such as along the southeast coast of Kodiak Island, Chignik Lagoon, and Pavlof, Canoe, Beaver or Balboa Bays, also could interfere with fishing activity. A case in point is a proposal by industry to run pipeline from the north side of the Alaska Peninsula to a tanker-loading facility’ in Canoe Bay.! Such po- tential conflicts should be studied before any development begins. 1. Glen Davenport, Area Management Biologist, Commercial Fish Div., Alaska Department of Fish and Game, Cold Bay, Alaska. Personal Communi- cation. Activities on all navigable waters would be by permit from the U.S. Army Corps of Engineers. Applications for Corps permits are circulated to all interested parties for comments and recommendations. Such recommendations may be included in the permit as stipulations to protect affected resources. In some cases permits may be denied. Gravel extraction from streams could affect fish spawning habitats. Where anadromous fish streams are involved, such activities would require a permit from the Alaska Department of Fish and Game, which would include stipulations for protection of fish resources. Similar activities on other streams and on tidelands require a permit from the Alaska Department of Natural Resources. The proposal would then be reviewed by the Alaska Department of Fish and Game, which would recommend stipulations.1 Spilled oil can have direct impact on fishing activities. During the development phase of the Cook Inlet oil field, fishermen frequently complained that even a thin film of oil on their nets rendered them stiff and difficult to handle and accelerated deterioration. The 1970 Kodiak incident also resulted in oiled gear. In the autumn of 1970, a shrimp fisherman reported his trawl had picked up a tar-like substance that contaminated his shrimp catch (U.S. Department of the Interior 1970). The major conflicts presented by marine geophysical surveys result from the use of high velocity explosives and the direct disturbance of fishing activities. Surveys using high velocity explosives, such as dynamite, Nitromon, or Geogel, have resulted in mortality to fish under varying circumstances. Falk and Lawrence (1973b) discuss both refraction and reflection surveys conducted with a variety of devices including vibroseis, dinoseis, flex-o-gun, pan air gun, seismogen air gun, aquapulse, and sparker. They experimented with various charges and determined that air guns are relatively harmless to fish. This is substantiated by experiments conducted by Wienhold and Weaver (1972) on coho salmon in Alaska. Surveys are now being conducted successfully without explosives, and there is little indication that explosives will be used in the Gulf of Alaska (Alaska Oil and Gas Association 1973). Conflicts between seismic operations and fishermen can be minimized by planning surveys outside the neighborhood of fishing activities. Such coordination and planning probably could have avoided the recent (September 1973) incident in Kachemak Bay, where seismic boats became entangled in and destroyed crab pot floats. A review of proposed programs by the Alaska Department of Fish and Game or the National Marine Fisheries Service should minimize such problems. ljay Bergstrand, Assistant Chief, Habitat Section, Alaska Dept. of Fish and Game, Anchorage, Alaska. Personal communication. 577 Perenosa Timber Sale, Afognak Island Although the Afognak timber sale is not directly related to pet- roleum activities in the area, it is discussed here in some detail because it does reflect the problems to be encountered when new develop- ments by a major industry occur. Afognak Island covers 458,800 acres and is one of the larger islands in the Kodiak Group. It possesses the general geomorphic characteristics of the Kodiak Mountains described earlier, but it is more moderate in relief than Kodiak Island, with slopes of about 30 degrees or less. Most precipitation is rain, which averages 150 cm. (60 inches) on the eastern coast. Less rainfall occurs in the western part of the island, while higher elevations receive more. Snow occurs in variable amounts between November and April. Drainage is generally deranged due to past glacial activity. Soil development has been minimal since the last glaciation, and soil depths vary between 46 and 92 cm. Organic soils are present in muskeg areas (U.S. Forest Service 1973). Afognak is one of the few forested islands in the Western Gulf area. The northern third of the island is completely forested, while the southern two-thirds are less densely covered. Interior portions of the island and other nonforested areas (western parts of the island) are covered with grasses and forbs with patches of alders and willow; 278,500 acres (1,100 sq. km.) are forested while 180,300 acres (730 sq. km.) are unforested. Most commercial timber is between sea level and 150 m. in elevation and within 2.5 km. of tidewater. The forest is essentially pure Sitka spruce--a very unique condition for this northwestern location. Briefly, fish and wildlife resources of the island include crab, shrimp, and halibut in offshore waters as well as trout and salmon (pink, coho, chum, and some sockeye and chinook) in the streams. Also present are Roosevelt elk (the only elk herd in Alaska, which consists of approximately 450 animals although the population is now declining), Sitka black-tailed deer (perhaps 1,100 animals), brown bear (population unknown) and such mammals as land otter, marten, beaver, red fox, muskrat, voles, shrews, squirrels, and hares. Birds inhabiting Afognak include willow ptarmigan, waterfowl, shore birds, and the rare and endangered bald eagle, peregrine falcon, and osprey. All of the above fauna are found within the sale area. Elk, salmon, and some eagle surveys have been made on the island, as well as very general habitat location and description surveys for these and certain other species. The proposal to sell timber on Afognak Island resulted from a study by a task force appointed by Alaska Governor Walter J. Hickel in the mid 1960s. The reported goal of the study group was to recommend likely ways of further utilizing Alaskan timber resources, broadening ASS Konak iy ISLANDS ua, LOCATION MAP units this reappraisal + unit’ next reappraisal ~~ prope ed permanent road pow Sale grea boundary eS barge loading site Figure 177 Proposed Perenos: : . . e nosa Timber Sale al ; ; : p imber Sale, Afegnak Island (from U.S. Forest Service 1977) eLs 579 and diversifying the economic base, and providing employment for Alaskans. It was decided in 1967 that a timber industry centered around the Kodiak Island group should be initiated. The U.S. Forest Service then began to plan for the development of the Afognak timber resource (U.S. Forest Service 1973). The task force felt that timber sales on other islands within state and local jurisdiction (Shuyak and Kodiak Islands) also could be planned at an appropriate time. The Perenosa Timber Sale, involving 525,000 MBF! of Afognak Island forest, was offered at oral auction by the U.S. Forest Service on June 4, 1968. The sale was awarded at a high bid of $27.05/MBF. The appraisal value was $4.35/MBF. During the remainder of 1968 and into 1969, the export market for log cants dropped and the original purchaser did not develop the sale. On July 15, 1969, the sale was assumed by another timber company. Export markets have since improved, and the present sale operator now wishes to proceed with the resource harvest. The Forest Service has revised the original scope of the sale and reduced the total sale volume, reportedly to preserve elk habitat, to protect crab rearing areas along the shore, and to reduce clearcut acreage. The scope of the present sale is summarized on Figure 177 and Table 102. A clearcut silvicultural system, using high-lead logging techniques, will be used almost exclusively. Some tractor logging may be done experimentally or where local soil or freezing conditions permit. Of the 200 km. of proposed logging road, approximately 75 km. will become high grade roads suitable for tourist and recreational use. Logs will not be stored in offshore waters, but will be decked on land and barged to a sawmill, presumably somewhere other than Afognak Island (U.S. Forest Service 1973). TABLE 102 Perenosa Timber Sale information, revised proposal (from U.S. Forest Service 1973). Total sale volume, MBF! Total clearcut acres logged Total number of clearcut units Average clearcut unit size (acres) Maximum unit size Smallest unit size Logging road mileage Logging period, years Volume logged per year, MBF Acres logged per year Note: The recomputed stumpage price for the sale is near $19.00/MBF. 1 MBF = thousand board feet of lumber, where a board foot is arbitrarily one 12 in. x 12 in. x 1 in. piece of wood. 332,329 12,074 121 100 228 34 140.3 10 32,200 1,200 580 581 There is considerable controversy over the Perenosa timber sale. Objections to the harvest of this timber resource can be divided into environmental, fish and wildlife, and socioeconomic concerns and are discussed below. Soil erosion is the greatest environmental concern pertaining to the Perenosa sale. Volcanic ash soils underlie the organic soil layer. Once this duff layer is removed, the ash soils are subject to erosion by wind and water runoff. This may be especially critical where logging or road building is planned on steeper slopes or near streams. U.S. Forest Service and other silviculturalists are also concerned with the potential of Sitka spruce to regenerate following logging operations. Comparatively poor restocking and regeneration occurred following logging around Kazakof Bay during World War II (Harris 1972) and following an insect kill in the Discoverer Bay area in the 1930s (U.S. Forest Service 1968). This is believed to be due to the intense competition seedlings received from grasses and forbs. The Afognak situation may be similar and is further complicated by the island's nutrient-deficient soils (particularly in growth-important nitrogen). Replanting spruce seedlings may be necessary to achieve desirable stocking after logging. To aid restocking, the mechanical removal or chemical destruction of competing plants could be used, but this action could cause further erosion problems and chemical poisoning of the soil, fish, and wildlife in the area. Reproduction since 1955 on sale areas in the Raspberry StraitAfognak Strait area has been quite satisfactory, however, and mechanical or chemical planting or treatment is not anticipated at this time.1 Logging slash disposal methods are another concern that have been questioned with allegations that insect infectations may threaten developing seedlings and surrounding healthy trees. Still another concern involves possible air and water pollution from sawmills. Logging also will disturb and displace some fish and wildlife. With good harvesting practices, wide leave strips along streams, and careful road layout, damage to fish and wildlife habitats could be minimal. The fear of damage to Afognak's commercial fishery due to poor harvesting practices has caused many people in the Kodiak area to oppose the sale. Poor logging practices could block salmon migrations and destroy the water quality of the spawning streams by siltation or increased water temperature. The effect of timber harvest on the elk population is unknown. Elk require some forest cover on their habitat range, but U.S. Forest Service personnel believe that the sale will benefit the elk population by providing more browse production and edge effect. Other observers fear that the removal of the forest cover will cause further reduction lRichard Woodrow, former Acting Forest Supervisor, Chugach National Forest, U.S. Forest Service, Anchorage, Alaska. Personal communication. of an already declining population. The brown bear population on the island is unknown. Some fear that logging activity will increase bear-man conflicts. The incompatability of these animals with man, combined with a likely increase in hunting pressure, may cause a decline in the bear population. The effect of the timber harvest on the deer population, as well as small mammals in the food chain, is also unknown; experience elsewhere indicates that the effects should be minimal or perhaps enhancing. The U.S. Forest Service is attempting to protect the habitat of rare and endangered peregrine falcons which migrate through the sale area, but some feel these efforts may be insufficient. In summary, it can be stated that some adverse effect on fish and wildlife and an associated population decrease of some species will occur with the timber harvest and increased human use of the area. Much of the conflict between Afognak resource users centers around the socioeconomic aspects and implications of the sale. Economically, many people (not only Kodiak area residents) question foreign money interests, such as Japanese, harvesting Alaska resources and selling them abroad, particularly when national and local wood demand and prices are quite high. The U.S. Forest Service claims that this is an opportunity to reduce the United States balance of payments deficit. Many Kodiak area residents feel that the taxes received from sale receipts will not pay the costs of increased services and school facilities that will be needed to accommodate the estimated 50-120 new jobs created. Local residents state that they do not want to pay this added burden. The sawmill will increase demand for power, and there is some concern over potential business and residential energy shortages if the sawmill is located in Kodiak. Concern also has been voiced over cost/benefit and economic profile computations in view of the rotation age (110 years) and the use of Chugach Working Circle statistics rather than local data alone. With logging, the island will lose its wilderness and primitive character. The U.S. Forest Service maintains that several nearby areas (Kodiak National Wildlife Refuge, Katmai National Monument, Nellie Juan Wilderness Study Area) provide adequate wilderness. Some who disagree maintain that their personal recreational areas will be lost with greater use of the island. Clearcut patches are also opposed on aesthetic grounds, even though the U.S. Forest Service considers it necessary from a biological and economic standpoint. Another objection to the sale arises from Koniag, Inc. and village corporations selecting land pursuant to the Alaska Native Claims Settlement Act of 1971 (PL 92-203). Villages presently qualified to select land on Afognak Island within the sale area could choose as much as one- third of the sale area. Other villages are alleged to exist by the Native corporations and, if certified, most of Afognak Island might 582 583 be selected under the terms of the Act. The U.S. Forest Service is protesting the qualification of some of these additional villages.! Koniag, Inc. and villages of Afognak Island oppose the sale primarily on fishery, environmental, aesthetic, and ethnic-historical grounds. Even though these corporations would receive the financial return (after costs) of the sale, they question the dollar value in relation to other values which might be lost. In essence, local residents and Native groups question how such a sale and resultant development might affect their quality of life. All 12 individuals who testified at the August 1973 public hearing in Kodiak on the Draft Environmental Statement for the Perenosa Sale, opposed the sale.2 Data Gaps Some feel that several things pertinent to the understanding of the sale area and the impact of the logging operation are poorly known and need to be better understood. A detailed soil survey has not been made, and the consequences of removing the duff layer and exposing the erodable soil have not been determined on Afognak. The U.S. Forest Service maintains that harvesting in the Afognak Straits area has not created any erosion problem and likewise shouldn't on Afognak. More detailed fishery and wildlife surveys might be necessary for factual impact analysis, yet, the U.S. Forest Service feels that the data are adequate. Finally, the relationships between socioeconomic costs and benefits have not been satisfactorily related to the local people. Impact on Quality of Life and Aesthetics The study area is largely rural and much of it is undisturbed wilderness, showing little evidence of man's activities. More than 16,000 sq. km. (4 million acres) are in permanent status as National Forest, National Monument or National Wildlife Refuge. These areas are managed by agencies with responsibility for considering at least a portion of these lands for primitive and wilderness status under the Wilderness Act of 1964 (Public Law 88-577). Additional lands are withdrawn under the Alaska Native Claims Settlement Act of 1971 (Public Law 92-203) for possible inclusion into one of these management systems. The rugged coastlines and numerous bays and islands are a spectacular landscape. John Raynor, Timber Management Assistant, Chugach National Forest, Anchorage, Alaska, and Gordon Edgars, former Acting Timber Manage- ment Assistant, Kodiak Work Center, Chugach National Forest, Kodiak, Alaska. 2Gordon Edgars, Ibid. 584 Outside of the City of Kodiak (80 percent non-Native) and Cold Bay (mostly non-Native), most of the residents of the study area are Native--Unalaska Aleuts to the west and Kaniagmiut Eskimos to the east. These village people are predominately maritime (Hickok 1968). Hickok (1968) emphasizes that the Aleuts depend on their knowledge of the sea for a livelihood. To a large extent this is also true of the Kaniagmiut, although they are converting more rapidly than the Aleuts from a subsistence economy to dependence on the commercial fishery. To these people, the sea is a way of life that has undergone only gradual change for generations. Arnold (1968) described village Alaska with all its economic, educational, health, and service problems. He summarized as follows: "Village Alaska will persist because of circumstances and choice. What this means is suggested in the remarks (relating to American Indians generally) of an Indian Association spokesman."' Arnold then goes on to quote Munschenheim! as follows: "I am never surprised, but always dismayed, when well- meaning but poorly informed people ask why do not the Indians integrate themselves more effectively into the general society...to reply simply that probably they'd rather not, or, contrariwise, that they do not have the opportunity to integrate, would not, either way, properly answer the question. Nor would it be very informative to reply that for the most part they do not have the op portunity and that, in any case, they have strong attach- ment to their own cultural heritage and are understandably ambivalent in their reactions to the alien society which has engulfed them. This is, it seems to me, a reasonable statement of the case, but it is quite meaningless to anyone who is unfamiliar with the values on the one side of the equation, namely the character and quality of the cultural heritage to which Indians are attached." The primitive maritime lifestyle of Native residents in the study area seems well established. The adherence of the approximately fifty non-Natives in the villages and the non-Native residents of Kodiak and Cold Bay to such a lifestyle is more difficult to appraise. Most of the military are transient and any impact on them would be temporary. Many other non-Natives are, however, permanent or semi-permanent residents of the area. Perhaps they feel this same quality of life compensates for generally low incomes, inconveniences, and high priced manufactured goods. \carl Munschenheim, ''The National Significance of Indian Health," speech delivered before the Fourth National Conference on Indian Health, Nov. 30, 1966. 585 Steinhoff (1969) in a study of the value of wildlife and related recreation on the Kenai National Moose Range, analyzed how Alaska residents rated the values of accessibility, facilities, wilderness, wildlife, and scenery. He determined that 76 percent of the Alaska resident respondents to his questionnairee listed the Moose Range as one of the factors that induced them to stay in Alaska. Knight and Hornocker (1970) found that a large preponderance of Idaho residents listed similar amenities of environment, open space, hunting and fishing, and outdoor recreation as their major reasons for remaining in Idaho. Pearse (1971) in discussing the proposal for an international Arctic Wildlife Range, emphasized the non-industrial values that, though difficult to measure, must be recognized and equated with industrial values. Large expanses of wilderness with its wildlife and the existing way of life of the Native people are among these values. He emphasized that once destroyed, neither can be reconstructed. Weeden (1969) suggested that petroleum development could be carefully controlled and could provide economic benefits to the state with minimum disruption of these values. He stressed that this would require a rigid acceptance of a middle course of restrained development which has not yet been achieved in Alaska. Petroleum development in the Cook Inlet area has had considerable impact on these non-industrial values (Evans 1969). Even an oil rig in Shelikof Strait, for example, would have significant impact on the many miles of shoreline of the Katmai National Monument and would destroy the wilderness character of the area. The haste to explore the Arctic Slope oil fields has also led to the visual and erosional impact described by Brooks et al. (1971). The "'Hickel Highway,'' pushed through the Brooks Range without advance notice, consideration of impact on other resources, or consultation with affected peoples, is a case in point. The Natives of the Arctic Slope, and Anaktuvuk Pass in particular, are most concerned about the effect this type of access will have on their way of life (Upicksoun 1973). Norgaard (1972) believes that the major costs to Alaskans of petroleum development will be in terms of wilderness, hunting and fishing, and outdoor recreation--the amenities that have great value to many of the state's citizens. Even if not a drop of oil is spilled, there still will be roads, increased traffic, construction of shore-based facilities, removal of construction materials, and new population centers. All these will have tremendous impact on the aesthetic and wilderness character of the study area. These activities plus the lure of jobs (however transitory), the probable increased cost of living, and the unplanned access to the land, all will cause changes in the lifestyle of village Alaskans within the study area. Whether or not these changes are desirable in the long run, they will, as Pearse (1970) has pointed out, be irreversible. Arnold (1968) indicated that they may be undesirable, particularly if they occur too rapidly. While impacts of petroleum development on quality of life and aesthetics can be predicted fairly reliably, little information is available to determine the quality of life that Alaskans desire or how to evaluate it. Neither do we know how to evaluate the aesthetic and wilderness values of a landscape. Because they are so seriously affected by industrial development, these values should be studies as carefully as the natural biotic systems that will be affected. 586 587 Literature Cited Aldrich, J.S. 1970. Review of the Problems of Birds Contaminated by Oil and Their Rehabilitation. U.S. Bureau of Sport Fisheries and Wildlife Resource Publ. 87. Washington, D.C. Alaska Oil and Gas Association. 1973. "Description of Petroleum In- dustry Operations." Submittal 'A' for Corps of Engineers Cook Inlet Environmental Impact Statement. Arnold, R.D. 1968. "Village Alaska." In: Alaska Natives and the Land. Federal Field Committee for Development Planning in Alaska. Anchorage, Alaska. Black, R. 1973. "Growth Rates of Intertidal Molluscs as Indicators of Effects of Unexpected Incidents of Pollution." Journal of the Fisheries Research Board of Canada 30(9) :1385-1388. Blumer, M., G. Souza and J. Sass. 1970. "Hydrocarbon Pollution of Edible Shellfish by an Oil Spill." Marine Biology 5:195-202. Brooks, J.W., J.C. Bartonek, D.R. Klein, D.L. Spencer, and A.S. Thayer. 1971. Environmental Influences of Oil and Gas Development in the Arctic Slope and Beaufort Sea. U.S. Bureau of Sport Fisheries and Wildlife Resource Publ. 96. Washington, D.C. Dean, R.A. 1968. "The Chemistry of Crude Oils in Relation to Their Spillage on the Sea." In: Carthy, J.K. and D.R. Arthus, eds. The Biological Effects of Oil Pollution on Littoral Communities. Supplement to Vol. 2 of Field Studies, Field Studies Council. Environmental Protection Agency. 1971. Studies on Industrial Effluent and Its Effect on Water Quality in St. Paul and Kodiak Harbors, and Gibson Cove. Environmental Protection Agency, Region X, Alaska Operations Office. Anchorage, Alaska. Erickson, R.C. 1963. "Oil Pollution and Migratory Birds."' Atlantic Naturalist 18(1):5-14. Evans, C.D. 1969. "Environmental Effects of Petroleum Development in the Cook Inlet Area." In: Proceedings of the 20th Alaska Science Conference, College, Alaska. Aug. 2427, 1969. Evans, C.D., E. Buck, R. Buffler, G. Fisk, R. Forbes, and W. Parker. 1972. The Cook Inlet Environment, A Background Study of Avail- able Knowledge. Prepared for Alaska District Corps of Engineers by University of Alaska, Resource and Science Service Center. Anchorage, Alaska. Falk, M.R., and M.J. Lawrence. 1973a. Acute Toxicity of Petrochemical Drilling Fluids Components and Wastes to Fish. Department of the Environment. Winnipeg, Manitoba, Canada. Technical Report Series No. CEN T-73-1. 588 Falk, M.R., and M. J. Lawrence. 1973b. Seismic exploration: Its Nature and Effects on Fish. Department of the Environment. Winnipeg, Manitoba, Canada. Technical Report Series No. CEN/T- 73-9. Friede, J., P. Guire, R. Gholson, E. Gaudy, and A. Gaudy. 1972. Assessment of Biodegradation Potential for Controlling Oil Spills on the High Seas. U.S. Coast Guard Project No. DAT 204-72. Oklahoma State University. Stillwater, Okla. Gutsell, J.S. 1921. Bureau of Fisheries. Document No. 910, Appendix VII to the report of the U.S. Commissioner of Fisheries for 1921. Dept. of Commerce, Bureau of Fisheries. Washington, D.C. Harris, A.S. 1972, Natural Reforestation After Logging on Afognak Island. U.S. Dept. of Agriculture, Forest Service. Pacific Northwest Forest and Range Experiment Station Forest Research Note PNW-176. Hickok, D.M. 1968. "Land and Ethnic Relationships." In: Alaska Natives and the Land. Federal Field Committee for Development Planning in Alaska. Anchorage, Alaska. Hoult, D.P. 1971. Marine Pollution, Concentrating on the Effects of Hydrocarbons in Salt Water. Unpublished manuscript. Massachusetts Institute of Technology. Cambridge, Mass. Hufford, G.L. 1971. The Biological Response to Oil in the Marine Environ- ment. Proj. No. 714141/003 Rep. U.S. Coast Guard. Washington, D.C. Kash, D.E., I.L. White, K.H. Bergey, M.A. Chartock, M.D. Devine, R.L. Leonard, S.N. Salmon, and H.W. Young. 1973. Energy Under the Oceans. A Technological Assessment of Outer Continental Shelf Oil and Gas Operations. University of Oklahoma Press, Norman, Okla. Kinney, P.J., D.K. Button and D.M. Schell. 1969. "Kinetics of Dissipation and Biodegradation of Crude Oil in Alaska's Cook Inlet." In: Pre- vention and Control of Oil Spills. American Petroleum Institute and Federal Water Pollution Control Administration. New York. Kinney, P.J., D.K. Button, D.M. Schell, B.R. Robertson, and J. Groves. 1970. Quantitative Assessment of Oil Pollution Problems in Alaska's Cook Inlet. Report R-69-16. Institute of Marine Science, University of Alaska. College, Alaska. Knight, R., and M. Hornocker. 1970. A Quality Life in Idaho. Typed manu- script. College of Forestry, Wildlife and Range Sciences, University of Idaho. Kunhold, W.W. 1970. The Influence of Crude Oils on Fish Fry. FAO Con- ference. Rome, Italy. 589 Lee, R.F., R. Sauerheber, and A.A. Benson. 1972. "Petroleum hydrocarbons: Uptake and Discharge by the Marine Mussel Mytilus edulis." Science 177:344. 1973. Impact on New England Environ- Massachusetts Institute of Technology. Georges mental Quality of Hypothetic Regional Petroleum Developments. Bank Petroleum Study. MIT Offshore Qil Task Force Group Report No. MITSG 73-5. Massachusetts Inst. of Technology. Cambridge, Mass. Nelson-Smith, A. 1970. "The Problem of Oil Pollution of the Sea.'' Adv. Mar. Res. 8:215-306. Norgaard, R.B. 1972. Resource Use Conflicts Involving Oil and Gas in Alaska. Institute of Social, Economic and Government Research, University of Alaska. College, Alaska. Oguri, M., and R. Kantor. 1971. "Primary Productivity in the Santa Barbara Channel." In: Biological and Oceanographic Survey of the Santa Barbara Channel Oil Spill 1969-1970. D. Straughan, ed. Vol. I Biology and Bacteriology, Sea Grant Publ. No. 2. Allan Hancock Foundation. University So. Calif. Los Angeles, Calif. 1971. In: Ecological Effects of Oil Pollution on Littoral Ottway, S. Cowell, E.B., ed. Institute of Petroleum. London. Communities. Pearse, P.H. 1971. "Some Economic and Social Implications of the Proposed International Arctic Wildlife Range." In: University of British Col- umbia Law Review, Vol. 6(1). Supplement June 1971. (Proceedings of the Arctic International Wildlife Range Conference October 21 and 22, 1970). 1973. Toxicity and Avoidance Tests with Prudhoe Bay Oil and 1973 Proceedings of the Joint Conference on Pre- Amer. Pet. Inst., Environmental Washington, D.C. Rice, S.D. Pink Salmon Fry. vention and Control of Oil Spills. Protection Agency, and U.S. Coast Guard. Speyer, J.L. and M.J. Tolkoff. 1970. Field Studies on the Long Term Effects of Oil Pollution on the Marine Life of Kodiak, Alaska. June 16-August 31. Harvard University Biological Laboratories. Cambridge, Mass. 1970. Toxicity Tests with Oil Disper- Sprague, J.B., and W.G. Carson. Nova Scotia. sants in Connection with Oil Spill at Chedabucto Ba: Fisheries Research Board of Canada Tech. Report No. 201. Steinhoff, H.W. 1969. Value of Wildlife and Related Recreation on the Kenai National Moose Range. A report submitted to the Bureau of Sport Fisheries and Wildlife, Dept. of the Interior. Washington, D.C. 590 Straty, R.R. 1973. "Ecology and Behavior of Juvenile Sockeye Salmon, Onchorhynchus nerka in Bristol Bay and the eastern Bering Sea." International Symposium for Bering Sea Study, Vol. I. Templeton, W.L. 1972. "Ecological Effects of Oil Pollution." Literature Review 44(6) :1128-1134. Tryck, Nyman, and Hayes. 1971. Kodiak Metropolitan Area Interim Regional Water Quality Management Plan. Tryck, Nyman, and Hayes, Consulting engineers. Anchorage, Alaska. Upicksoun, J. 1973. On the overall position of the Arctic Slope Regional Corporation concerning Sec. 17 D-2 Study Areas of the Alaska Native Land Claims Settlement Act. Statement before the Federal- State Land Use Planning Commission for Alaska by Joe Upicksoun, president, Arctic Slope Regional Corporation. Barrow, Alaska. U.S. Army, Corps of Engineers. 1973. Proposed Small Boat Harbor, Kodiak, Alaska. Preliminary draft, environmental impact statement. Anchorage, Alaska. U.S. Coast Guard. 1973. On-Scene Coordinator's report. Major oil spill, Cold Bay, Alaska. March 7, 1973. U.S. Coast Guard, Captain of the Port. Anchorage, Alaska. U.S. Department of the Interior. 1970a. Oil and Refuse Summary Alaska. Federal Water Pollution Control Administration, Alaska Office. Anchorage, Alaska. (Now Environmental Protection Agency, Alaska Operations Office.) U.S. Department of the Interior. 1970b. Documentation of Kodiak Oil Pollution Incident. March, 1970. Federal Water Pollution Control Administration, Alaska Operations Office. U.S. Department of the Interior. 1971. Incidents on the Outer Continental Shelf Resulting in Injury and Property or Environmental Damage. (1953 to Nov. 17, 1971) Geological Survey, Conservation Division. U.S. Department of the Interior. 1972. Final Environmental Impact Statement. Trans-Alaska Pipeline System. U.S. Department of the Interior. 1973. Final Environmental Statement, Pro- posed 1973 Outer Continental Shelf East Texas general oil and gas lease sale. Bureau of Land Management Publ. FES 73-19. U.S. Forest Service. 1968. Multiple Use Survey Report, Perenosa Timber Sale. U.S. Department of Agriculture, Alaska Region, Chugach National Forest, Anchorage Ranger District. 591 U.S. Forest Service. 1973. Draft Environmental Statement, Proposed Timber Harvest in the Perenosa Timber Sale. U.S. Department of Agriculture, Alaska Region, Chugach National Forest. Warner, J.L., J.W. Graham, and R.G. Dean. 1972. Prediction of the Movement of an Oil Spill on the Surface of the Water. Offshore Technology Conference paper No. OTC 1550. Weeden, R.W. 1969. Man in Nature: A Strategy for Alaskan Living. Paper presented at the Tundra Conservation Conference, Edmonton, Alberta, Canada. October 16, 1969. Wienhold, R.J. and R.R. Weaver. 1972. Seismic Air Guns' Effect on immature Coho Salmon. Society of Exploration Geophysicists. (Preprint) Tulsa, Oklahoma. Wilber, C.G. 1969. Biological Aspects of Water Pollution. Charles C. Thomas, Publisher, Springfield, I11. XI. DATA GAPS INTRODUCTION Except for local areas, little environmental information about the study area is available. The amount of detail available varies with the topic, location, and time of year of observations. There are enough data to provide an overall understanding of the study area, but detail is insufficient to provide an adequate baseline for evaluating change which might result from a few of the more significant data gaps discussed below. GEOMORPHOLOGY Perhaps the most significant lack of data under this category is the absence of detailed bathymetry over most of the shelf. Areas around Kodiak and other islands and along the Alaska Peninsula coast are only moderately well charted, while the outer shelf areas, especially over the shallower banks, are inadequately charted. Especially critical are the areas charted before the 1964 earthquake, some of which underwent significant changes in elevation during the earthquake. Any offshore development would require bathymetric studies. OCEANOGRAPHY Oceanographic investigations in the Gulf of Alaska area have been conducted sporadically during the past 45 years. These studies have primarily been oriented towards evaluating the fisheries of the region. Only recent studies have gathered baseline data that lead to a basic understanding of the entire air-sea system. Most of the data have been collected in the open ocean, few data exist for the shelf areas. Such observations as have been made on the shelf are scattered in location and time. Most observations have been made during summer months. Because of unfavorable weather conditions at other times of year, there has been, and is presently, only one systematic study to gather a set of continuous observations of physical data in the Gulf of Alaska shelf waters. The Institute of Marine Science has a project under the direction of Dr. Tom Royer that has been making hydrographic observations along a transect perpendicular to the Seward coastline to just beyond the continental slope approximately bimonthly since December 1970. During the summer of 1967, an extensive survey program around 592 Kodiak Island was begun, but the project died due to lack of funding after only one cruise. All other observations have been made at various times on miscellaneous foreign and domestic cruises in the area. Most of the physical oceanographic information collected yield little insight into the short-term variations of conditions over the continental shelf. Apparently, the air-sea interaction over the shelf modifies oceanographic conditions to a large extent which requires local data before local dynamics can be completely understood (Royer 1972). Very limited chemical data are available for the shelf area (Longerich and Hood 1972). Chemical properties change daily and seasonally and are closely related to the physical transport and dispersion of water masses. Most of the present data consist of short-term observations of specific chemical parameters. No information exists on the seasonal effects or dynamic processes which control these concentrations. CLIMATE Available climatic information is of limited value. Development at a specific location will require detailed local data. Gathering of data will be difficult and costly because of the remoteness of the area and the lack of local personnel to run stations. Even then, data for a specific site may not become useful until that site has been occupied for some time. Knowledge of offshore weather could be increased by weather buoys. Such a buoy is currently operating southeast of Kodiak just outside the study area, but is still being tested and is encountering operational difficulties. There are no plans. for use of any buoys within the study area. Some offshore data could be gathered on platforms if they are constructed in the area. GEOLOGY Only a basic geologic framework can be established from existing reconnaissance work. Most detailed information about the area has been obtained by petroleum and mining companies, and is not generally available due to its proprietary nature, Knowledge of sand and gravel resources will be critical for development of onshore facilities. The Resource Planning Team of the Joint Federal-State Land Use Planning Commission tentatively identified streams that could have sand and gravel resources. 593 594 The oil and gas potential of the study area is completely unknown. The actual outlines of potential basins have not been adequately defined, even by the oil companies. Estimates of up to 40 billion barrels have been made for the outer Kodiak shelf. The potential will remain purely speculative until wells are drilled and the area is tested. Apparently, no large scale effort will be made by petroleum companies to obtain additional geologic data in the study area until there is some assurrance of lease sale, although some companies may continue reconnaissance studies. Exploration interest could change drastically, especially along the Alaska Peninsula, if a significant discovery were made at the Cathedral River well, which is presently being drilled. Little is known about oil reaching the environment through natural processes. The U.S. Bureau of Mines has begun investigation of natural oil seeps, and some data should be available soon. Other resources of the area have not been evaluated. Mineral potential is probably high in certain areas but further exploration will not be carried out until the land status is decided. The geothermal and wind power potential is also high, and may be further evaluated in the near future. The University of Alaska Geophysical Institute is investigating the feasibility of an experimental windmill farm at Cold Bay, and also has a proposal in to CRREL to drill a test well on Augustine Island to study its geothermal potential. The predictability of earthquakes and volcanic eruptions is another data gap. The establishment of a seismic net in the Shumagin Islands in the summer of 1973 is just the first step toward earthquake prediction in the Kodiak-Shumagin seismic gap. With the recent breakthrough in prediction capabilities, there is a good chance that some major losses at present and future facilities in the area could be avoided. Volcanic eruptions probably could be predicted also, if a seismic net was expanded to other active volcanoes besides Augustine Volcano. HYDROLOGY No detailed hydrologic data are available except in the Kodiak area where water quality and sediment samples are occasionally collected at a few stream-gauging stations. Although runoff is high, it is irregular and seasonal in the Kodiak area. Groundwater is limited and restricted to alluvial valleys. Kodiak has serious water shortage, due to limited reservoir capacity and low winter runoff. 595 Development of onshore facilities would require a careful evaluation of water availability at the site. Observations of streamflow over several years would be necessary to evaluate stream water availability, and test wells would have to be drilled to evaluate groundwater. Due to the irregular high peak runoffs characteristic of the area, there is a high potential for flash floods along the lower reaches of streams. Careful evaluation of potential flood hazards for onshore facility sites also would be an important aspect of any development plans. BIOLOGY Life history information is deficient for many species occupying the Gulf of Alaska, particularly where the timing of various life stages is altered as compared with more southern populations of similar species. Information on seasonal abundance is fragmentary at best. For most species, qualitative and quantitative data are totally lacking. Migration patterns of many species are totally unknown. Detailed information is lacking even for such commercially important species as salmon. Only fragmentary information is available on inshore and offshore seasonal movements of the most commercially important species. For instance, the movements and requirements of salmon during their early life cycle at sea is almost unknown. There are also few data on environmental conditions that limit species at the extremes of their range. The factors in the marine environment that might cause sockeye salmon populations to fluctuate widely are unknown. For most commercially important species, data on which to establish optimum harvest rates are lacking. The impact of habitat changes on these optimum rates which might occur with outer continental shelf development cannot be appraised. The interrelationships among marine species and their habitats are unclear. For instance, the likely extent and duration of damage to zooplankton or to marine macrophytes with development, and its impact on higher trophic levels, are unknown. The effect of cumulative stresses are not known for any species. The effect or significance of environmental change cannot be measured because baseline data in this ecosystem are totally lacking. For instance, Black (1973) points out that knowledge of the normal growth rates of a mollusks could be used as a rough measure of the impact on it resulting from an alteration of its habitat. No such growth information is available for species in the study area. The National Marine Fisheries Service initiated studies in Prince William Sound to establish present hydrocarbon levels in invertebrates. Similar studies should be conducted in the Gulf of Alaska. 596 In general, the basic effects of oil on organisms and their food chain are poorly understood although the MIT (1973) offshore oil task group lists the impact of oil on many species, little work has been done in cold water areas that could be applied to the study area. Few comprehensive studies have been conducted of oil spills. The work of Blumer et al. (1970) on the West Falmouth Massachusetts oil spill is probably the most comprehensive. Even that, however, lacked baseline data to compare with changes that might have resulted from the spill. The mechanisms of toxicity have not been worked out, particularly with regard to the ability of organisms to concentrate potentially carcinogenic compounds which may be passed upward through the food chains Some studies have opened up entirely new questions. Rice's (1973) study of avoidance of oil by pink salmon fry raises the possibility of interference with olfactory mechanisms that guide migration of both fry and adults. On the other hand, these fish might have the capacity to avoid oil whenever they have the opportunity. Some work has been done on predicting the course and dispersion of an oil spill. Warner et al. (1972) applied the factors of Coriolis force and vertical kinematic eddy viscosity to wind and current data to derive a model that would have predicted the course of the Chedabucto Bay spill. With data available from local sourees such as fishermen and weather forecasters, the course of a spill in the Western Gulf could within reasonable limits, be predicted about two days in advance.1 Long-term predictions would, however, require better data on winds and currents than are-available at present for most of the study area. More climatological stations could provide such data. Some work has been done on rates of biodegradation of oil (Kinney et al. 1969, Friede et al. 1972). It is known that the rate varies inversely with temperature, but much has yet to be learned about the rate at which oils will change form and toxicity under various conditions. 1. F. F. Wright, Oceanographer, Marine Advisory Program, University of Alaska, Anchorage, Alaska. Personal communication. 2. 4H. W. Searby, Climatologist, Arctic Environmental Information and Data Center, Anchorage. Personal communication. 597 SOC IOECONOMICS A review of the socioeconomic data for the study area reveals several particular data gaps. 1. Ethnology of Rural Populations. Although current and past life styles have been described, it is not known how rural inhabitants feel about the desirability, extent, and direction of future change. Natives may develop this information as they proceed with land selection under the Alaska Native Claims Settlement Act (PL-92-203). 2. Land Tenure. Perhaps the most significant data gap involves future land tenure. The land situation is currently in a state of flux pending settlement of the Alaska Native Claims Settlement Act (PL-92-203). It is probable that a large portion of the coastal zone probably will be under either private ownership or controlled by individuals, Native villages, and regional corporations. This could include most of Kodiak Island plus much of the coastline south of Katmai National Monument, a total coastal zone greater than that of the state of Texas. How this private control of a large portion of the coastal zone will affect development in the area remains to be seen. 3. Tourism. Data on the potential for tourism in the Western Gulf area is not adequate. Some studies have been made in adjacent areas being considered for parks and monuments. Literature Cited Black, R. 1973. "Growth Rates of Intertidal Molluscs as Indicators of Effects of Unexpected Incidents of Pollution."" Journal of the Fisheries Research Board of Canada. 30(9):1585-1388. Blumer, M., G. Souza, and J. Sass. 1970. "Hydrocarbon Pollution of Edible Shellfish by an Oil Spill.'"' Marine Biology 5:195-202. Friede, J., P. Guire, R. Gholson, E. Gaudy, and A. Gaudy. 1972. Assessment of Biodegradation Potential for Controlling Oil Spills on the High Seas. U.S. Coast Guard Project No. DAT 204-72. Oklahoma State Univ- versity. Stillwater. Kinney, P. J., D. K, Button, and D. M. Schell. 1969. "Kine- tics of Dissipation and Biodegradation of Crude Oil in Alaska's Cook Inlet."'" In: Prevention and Control of Oil Spills. American Petroleum Institute and Fed- eral Water Pollution Control Administration. New York. Longerich, L. and D. W. Hood. 1972. "Chemical Oceanography of the Gulf of Alaska." In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R 72-23. MIT. 1973. The Georges Bank Petroleum Study. Vol. II. Impact on New England Environmental Quality of Hypo- thetical Regional Petroleum Developments. Offshore Oil Task Group Report No. MITSG 73-5. Cambridge, Mass. Rice, S. D. 1973. Toxicity and Avoidance Tests with Prudhoe Bay Oil and Pink Salmon Fry. 1973. Proceedings of the Joint Conference on Prevention and Control of Oil Spills. Amer. Pet. Inst., U.S. Environmental Protection Agency, and U.S. Coast Guard. Washington, D.C. 598 Royer, T. C. 1972. "Physical Oceanography of the Northern Gulf of Alaska."" In: A Review of the Oceanography and Renewable Resources of the Northern Gulf of Alaska. Donald H. Rosenberg, ed. Institute of Marine Science, University of Alaska, Fairbanks. Report R 72-23. Warner, J. L., J. W. Graham, and R. G. Dean. 1972. Prediction of the Movement of an Oil Spill on the Surface of the Water. Offshore Technology Conference paper No. OTC 1550. 599 1880-75