Loading...
HomeMy WebLinkAboutState of Alaska Long Term Energy Plan, Appendix, 1982ENE 1982 Report 044 82/ap | &) State of Alaska “Long Term Energy Plan Appendix Department of Commerce and Economic Development Division of Energy and Power Development Prepared by BOOZ-ALLEN & HAMILTON INC. and * Homan-McDowell *Pa ENE NC 044 82/ap duncid ee tare ISSUED TO [ATCO OL AAO —n ————— The 1 nary, the Report and Appe er of copies of the report are ay on of Energy and Power Devel 99501 Steve (9-507 naam HIGHSMITH 42.225 PRINTEDINU.S.A. APPENDIX RECEIVED “AY 12 1982 ALASKA POWER AUTHORITY State of Alaska Long Term Energy Plan Jay S. Hammond Governor Charles Webber Commissioner Department of Commerce and Economic Development Lloyd M. Pernela Director Division of Energy and Power Development II-A II-B Li=€ II-D iE Sr III-A LLB) LV-A IV-B IV-C IV-D IV-E TVS LIST OF APPENDICES Regional Energy Balances Community Energy Data Base Historical Trends in Motor Vehicle Fuel Consumption Regional Profiles Residential Energy Use Calculations Petroleum Production Revenue Forecasts Description of Alaskan Refineries Petroleum Product Transportation Alaskan Electric Utilities Utility Capacity and Generation Statistics Energy Resource Estimate References Electric Generation Technology Calculations and Assumptions Extended Railbelt Capacity Scenarios Summary of Energy Programs within Alaska Energy Research, Development and Demonstration Projects, Division of Energy and Power Development Bulk Fuel Revolving Loan Fund and Emergency Fund Load Program Reconnaissance Studies, Alaska Power Authority Feasibility Studies, Alaska Power Authority Power Development and Demonstration Projects, Alaska Power Authority Electric Power Grant Program, Department of Administration IV-H Iv=I IV-J IV-K IV-L IV-M IV-N IV-O Bulk Fuel Storage Grants, Department of Community and Regional Affairs Legislative Grants for Rural Village Electrification, Department of Community and Regional Affairs Coastal Energy Impact Program, Department of Community and Regional Affairs Technical Energy Audits, Department of Transportation and Pubic Facilities Energy R&D Projects, Department of Transportaion and Public Facilities Regional Allocation of State Energy Projects and Funds Summary of Public Review Comments Public Hearings Testimony alae APPENDIX I-A ENERGY BALANCES APPENDIX I-A ENERGY BALANCES State Total Major Regional Groups - Extended railbelt - Bush regions - Southeast Regions ~ Arctic Slope - Subarctic Coast - Alaska Peninsula/Aleutian Islands - Southwest Coast - South Central - Prince William Sound - Fairbanks/Alaska Highway - Interior - Southeast ie — 1 REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) State Total FUEL Solids Crude Petro Gas Hydro Elect Total (1) Production |16,766/3,431,548 925,322} 7,230 S< 4,380,866 (2) Imports as 80,922) 47,317 = = - 128,239 (3) Exports -270| 3,341,978] -67,534 -47,322 - - |-3,457,104 am (4) Stck/reinj - - - |-682,420 - - | -682,420 (5) TPE 16,496 170,492] -20,217 195,580} 7,230 - 369,581 | i (6) Electricity +12,177 - |-11,330 -45,031] -7,230 17,343 -58,425 (7) E. Prod/tran - -16,143] -3,006 -77,121 -3,876 -100,146 (8) Refineries -}| -154,349|+153,163 -5,513 -61 -6,760 (9) Stat. Dif. - - - i - = (10) TFC 4,319 8610 67,915 13,406 204,250 (11) Industry 148 2,539 2,978 58,392 (12) Trans - 78,622 _ 78,622 (13) Comm 3,497 12,653 4,320 24,189 I (14) Marine - 10,340 = 10,340 (15) Nat. Def. 674 3,032 1,689 8,709 r (16) Res - 11,424 4,419 23,998 Pw REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) EXTENDED RAILBELT 18,662 FUEL Solids Crude Petro Gas Hydro Total (1) Production 12,626 210,262 309,712 3,378 535,978 (2) Imports — a 80,203 (3) Exports -270 |-124,944 -47, 322 —_— -240,070 (4) Stck/reinj -118,978 _ -118,978 (5) TPE r 356 cs aso | -67,872 | 143,412 | 3,378 | — [ 257.233 (6) Electricity -8,037 -4,974 -36,187 -3,378 +11,693 -40,883 (7) E. Prod/tran -10,762 seam -34,959 -1,620 -47,341 (8) Refineries -150,097 | +148,911 -5,258 -61 -6,505 (9) Stat. Dif. aaa aaa — — (10) TFC = 4,319 ES 81,065 67,008 [ >< | 10,012 162,404 (11) Industry 2,126 56,430 (12) Trans 57,967 57,967 (13) Comm 3,497 6,498 17,046 (14) Marine 7,476 7,476 (15) Nat. Def. 116 4,823 (16) Res 6,882 €°W-1 REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Bush Region Aggregation | FUEL Solids i Crude Petro Gas Hydro Elect Total (1) Production - eee eles - [<I osse. 086 (2) Imports - 5,381 29,163 Ht j] Al 34,544 (3) Exports - -3,217,034 oe | Ml 7 il 3,217,034 (4) Stck/reinj - a - -563,442 - 7 563,442 (5) TPE = 9,633 29,163 52,168 i iy 90,964 (6) Electricity Ti - -5,377 -8,844 a 3,307 -10,914 (7) E. Prod/tran a -5,381 -3,006 -42,162 -2,095 -52,644 (8) Refineries i -4,252 4,252 -255 i -255 (9) Stat. Dif. - ‘ ia - - T (10) TEC - ie al 25,032 907 1,212 ye ca (11) Industry inf I. 156 184 340 (12) Trans - 16,131 - - 16,131 (13) Comm - 3225 224 279 3,728 (14) Marine - 1,166 - - 1,166 (15) Nat. Def. - 2,916 364 616 3,886 (16) Res 7 1,594 163 1,900 p°W-I REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) SOUTHEAST FUEL Solids Crude Petro Gas Hydro Elect Total + (1) Production 4,140 : <] - 3, 852 <I 7,992 (2) Imports - - 13,492 - ~ - 13,492 (3) Exports - = - ~ - - + (4) Stck/reinj - - = ~ ~ = - (5) TPE 4,140 - 13,492 - 3,852 7 21,484 (6) Electricity -4,140 - -979 - -3,852 2,343 -6, 628 4 (7) E. Prod/tran = - - - -161 -16l + (8) Refineries ~ ~ ~ ~ 7 - (9) Stat. Dif. ~ ~ ~ — - ~ (10) TFC - Cc<] 2513 | C<T] 2,182 14,695 (11) Industry - 413 = 1,209 1,622 (12) Trans = 4,524 = 7 4,524 (13) Comm - 2,930 - 485 3,415 (14) Marine = 1,698 - e 1,698 (15) Nat. Def. - - - = _ (16) Res 7 2,948 > 488 3,436 REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region I: ARCTIC FUEL Solids ~ Crude Petro Gas Hydro Elect Total 4 a” (1) Production - 3,221,286] >< | 615,610 - <I 3,836,896 (2) Imports oS = 863** - - = 863 (3) Exports - -3,217,034 = - - - -3,217,034 + a (4) Stck/reinj = = 7 -563,442 - - -563,442 (5) TPE = 4,252* 863 52,168 = - 57,283 (6) Electricity c a -724 -8,844 = 2,102 -7,466 + (7) E. Prod/tran | 7 = -3,006 -42,162 -2,014 -47,182 | (8) Refineries - -4,252 4,252 -255 = -255 (9) Stat. Dif. c = - - - - (10) TFC 7 1,385 907 88 2,380 = (11) Industry - = (12) Trans eS 1,087 (13) Comm 7 154 Z (14) Marine - 89 (15) Nat. Def. 7 - (16) Res - 55 REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region II: RERICSG FUEL Solids Crude Petro Gas Hydro Elect Total + (1) Production = = S<l Z _ H< _ (2) Imports e - | 11,947 = - - 11,947 (3) Exports = - Pa - = _ = (4) Stck/reinj - - 7 - - - - Ib 1 (5) TPE = - 11,947 = = = 11,947 (6) Electricity = Es -1,533 = = 341 =1,192 (7) E. Prod/tran | Ss = = - -24 =24 H alt (8) Refineries = = - og oe - (9) Stat. Dif. - - = = = _ - T (10) TFC - 10,414 ~ Bay 10,731 (11) Industry = - a (12) Trans = 6,947 = (13) Comm - 1,829 = (14) Marine - 574 - (15) Nat. Def. - 300 - (16) Res - 764 = LT REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region III: ALEUTIAN ISLANDS/ALASKA PENINSULA = FUEL Solids Crude Petro Gas Hydro Elect Total + (1) Production = = = = - | (2) Imports - | - 5785 = - a BESS +- + (3) Exports - | - = = - 5 = (4) Stck/reinj - | = Sj - # L Lu (5) TPE 7 | - l 5,735 - L - _ 5,735 | (6) Electricity a = [ -1,474 = - 399) OND) (7) E. Prod/tran | - es a 1 aT = (8) Refineries = | - = = E _ (9) Stat. Dif. - | - | - = = iS IL (10) TFC = al 4,261 a | 398 4,659 iu (11) Industry | - 4 4 (12) Trans - - 2,010 | p>) Comm = 13 143 (14) Marine | - - 166 He (15) Nat. Def. - Deas 44 Sees REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region IV: SOUTHWEST COAST FUEL Solids Crude Petro Gas Hydro Elect Total = —— (1) Production = _ u a a I (2) Imports - - 7,224 - = as 7,224 (3) Exports - = ut “ ul i I (4) Stck/reinj = | = | a S - a z (5) TPE = 7 7,224 = u = 7,224 4 it T (6) Electricity - vm -1,101 1 349 -752 (7) E. Prod/tran | - - [ - - -26 =26 t— + (8) Refineries - = - a i M (9) Stat. Dif. = - = a ot m (10) TFC - eal 6,123 a ital 323 6,446 (11) Industry - - a + (12) Trans rc 4,076 - (13) Comm 4 672 | - | (14) Marine | ad 337 - (15) Nat. Def. 7 396 7 (16) Res 7 642 6am REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region V: SOUTH CENTRAL FUEL Solids Crude Petro Gas Hydro Elect Total E + + (1) Production - 210, 262 309,712 3,378 =~ 523,352 (2) Imports - 35,141 - = - - 35,141 T J T (3) Exports - -124,944 -56,895 -47,322 si - -229,161 + (4) Stck/reinj - - - |-118,978 - - -118,978 (5) TPE - 120,459 -56,895 | 143,412 3,378 - 210,354 t I + a (6) Electricity - - -850 -36,187 -3,378 8,951 -31,464 (7) E. Prod/tran r 2 ~ - -34,959 -1, 302 -36,261 (8) Refineries ~ -120,459 | +120,459 -5,258 -61 -5,319 (9) Stat. Dif. - _ - - - _ (10) TFC = al 62,714 | 67,008 Co] 7,588 137,310 ‘Z | an Industry - 1,669 1,500 55,740 4 (12) Trans - 43,733 - 43,733 | | (13) Comm - 4,407 2,479 10,381 (14) Marine - 7,292 - 7,292 | 4 t (15) Nat. Def. - = 452 3,402 (16) Res - 5,613 3757 16,762 = i OT°W-I REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) 380 Region VI: VALDEZ/CORDOVA FUEL Solids Crude Petro Gas Hydro Elect Total (1) Production - - as - - (2) Imports = 5,381 4,662 - ~ - 10,043 1 (3) Exports - = _ = - _ _ (4) Stck/reinj - - _ - - - _ 7 (5) TPE - 5,38 | 4,662 = - - 10,043 - L (6) Electricity a ad -1,308 - - 416 =892 a (7) E. Prod/tran - -5,381 = - -215 -5,596 (8) Refineries = ~ - ee as = (9) Stat. Dif. = = a - = = (10) TFC - <I] 3,354 = Cex] 201 3,555 (11) Industry - - - (12) Trans - 2,233 _ } (13) Comm - 557 = (14) Marine - 184 od (15) Nat. Def. = - = tt (16) Res - 7 iG jz REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region VII: FAIRBANKS/ALASKAN HIGHWAY FUEL Solids Crude Petro Gas Hydro Elect Total + (1) Production 12,626 “ <<! = = 12,626 + (2) Imports - 35,019 = = = = 35,019 (3) Exports 270 = -10,639 = = 7 -10,909 (4) Stck/reinj 7 ~ ~ ~ ~ - - (5) TPE 12,356 35,019 -10,639 = - - 36,736 (6) Electricity -8,037 - -2,816 - = 2,326 -8,527 : (7) E. Prod/tran - -5,381 - = -103 -5,484 (8) Refineries 7 -29,638 +28,452 ~ 7 -1,186 (9) Stat. Dif. = ie - - = _ (10) TFC 4,319 Cx] 14,997 - C<T] 2,223 21,539 (an) Industry 148 457 ~ = 605 ie Trans = 12,001 - - 12,001 (13) Comm 3,497 1,534 = 6,039 (14) Marine - - - IL (15) Nat. Def. 674 116 - (16) Res = 889 ~ REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region VIII: INTERIOR Glide FUEL Solids Crude Petro Gas Hydro Elect Total + —— 4 (1) Production a a it oa a tf (2) Imports a 5,381 3,394 = - = 8,775 + a El (3) Exports - - as - i Z 1 T +- (4) Stck/reinj a = = = - = = 5 (5) TPE a 5,381 3,394 e S 8,5 (6) Electricity - - -545 fs 116 -429 (7) E. Prod/tran [ 7 -5,381 se i —50 Oa (8) Refineries im =: i nm - - = (S) Staten Dice = a = i (10) TEC = 2,849 - 86 2,935 E<] aa) Industry ft - - (12) Trans ae 2 Ola - (13) Comm * 440 a (14) Marine = - = | (1s) Nat. Def. 305 “4 (16) Res a 93 a eT°w-1I REGIONAL ALASKAN ENERGY BALANCES -- 1980 (IN BILLION BTU) Region IX: SOUTHEAST FUEL Solids Crude Petro Gas Hydro Elect Total t (1) Production 4,140 = - 3,852 Cx] 7,992 (2) Imports - - 13,492 - = 7 13,492 (3) Exports = 7 7 = = 7 - - (4) Stck/reinj = = = ~ 7 = - (5) TPE 4,140 - 13,492 - 3,852 a 21,484 (6) Electricity -4,140 - -979 = -3,852 2,343 -6,628 + (7) E. Prod/tran a ~ a ~ -161 LOL (8) Refineries 7 ~ 7 ~ = = 4 (9) Stat. Dif. 7 - 7 = a - (10) TFC 7 i 12,513 - Co<] 2,182 | 14,695 (11) Industry - 413 7 (12) Trans = 4,524 - (13) Comm 7 2,930 - (14) Marine = 1,698 7 + (15) Nat. Def. 7 7 - (16) Res 7 2,948 - APPENDIX I-B COMMUNITY ENERGY DATA BASE This Appendix contains a community data base of energy information. It is organized into nine regional groups, and covers community- specific data including demographics, electricity, oil, and gasoline. The data base is the first attempt to use a computer to organize and analyze local energy statistics. As such the quality of its data is imperfect; the information is generally two years old, and its coverage of all communities is uneven. However, the data does accurately re- flect certain energy cost and usage patterns in the state that have not changed in a relative sense in the last two years. The primary sources for the community data base were the 1980 DEPD community survey, and the Alaska Power Administra- tion, Alaska Electric Power Statistics, 1960-1980. T’ad°l DATABASE 1 SLOPE DEMOGRAPHICS ELECTRICITY VILLAGE/ POPULAT- NUMBER CAPACITY AVERAGE ANNUAL AVERAGE ANNUAL TOWN ION FAMILIES (KW) DEMAND = CONSUMPT. PRICE COST (KW) (MWH) ($/KWH) (K) ANATUVAK PASS 176 27 75 19 170 0.50 85 AK ASOO! 84 13 50 16 140 0.50 70 BARFOW 2700 398 4700 1524 13250 0.15 2003 BARTER ISLAND 166 33 230 31 270 0.24 65 DEADHORSE 163 2650 451 3953 0.25 988 NUI@SUT 167 30 100 32 280 0.50 140 PT HOPE 420 69 200 68 600 0.20 120 FT LAY 51 22 30 17 150 0.50 75 WAINWPIGHT 330 56 350 80 700 0.30 210 . 7 Seeeeebes Seeeeees lenseeecs Suceeess secceces TOTAL 4317 648 8435 2239 19613 3756 AVERAGE 480 81 937 249 2179 0.35 417 WT. AVERAGE 0.19 PER CAPITA DATA 6 1.95 0,52 4.54 870 Z°a°l REGIONAL DATABASE REGION 1 ARCTIC SLOPE VILLAGE/ TOWN ANATUVAK PASS Ak ASOOK BARROW BARTER ISLAND DEADHORSE NUITQSUT PT HOPE PT LAY WAINWRIGHT TOTAL AVERAGE WT. AVERAGE PEP CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER ION FAMILIES ANNUAL CONSUMPT. PRICE ($/GAL) ($) (GAL) 30000 150000 84000 150000 215000 150000 =assesce 799000 133167 583 AVERAGE ANNUAL cost 1.29 193500 282000 406350 283500 1165350 1.74 1.75 STORAGE CAPACITY (GAL) 20000 240000 897350 190000 61000 800000 50000 150000 sasseces 2408350 301044 580 e°a°t PESTONAL DATABASE PEGION 1 APCTIC SLOPE VILLAGE/ TOWN ANATUVAK PASS AKASOOK BAPROW BAPTER ISLAND DEADHORSE NUTQSUT PT HOPE PT LAY WAINWRIGHT AVERAGE WT. AVERAGE PEP CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER ION FAMILI 176 84 2700 166 163 167 420 Si 390 4317 480 ES 27 13 398 33 39 GASOLINE AVERAGE AVERAGE ANNUAL STORAGE CONSUMPT. PRICE COST CAPACITY (GAL) (%/GAL) ($) (GAL) 25000 2.20 55000 20000 30000 30000 1.50 45000 40000 9000 40000 2.94 117600 50000 5500 2.94 16170 2.94 150000 suuessez szetss2= seses ss25 100500 233770 299000 25125 2.50 58443 49833 2.33 124 288 213 p°d-I REGIONAL DATABASE REGION 2 SUEBASCT COAST VILLAGE/ TOWN AF LACHAK AKIAK AKOLMUIT ALAKANUK AMBLER ANDREAFSKI ANIAK ATMAUTLUAK BETHEL EREVIG MISSION BUCKLAND CANDLE CHEF ORNAK CHEVAK CHUATHBALUK COUNCIL CROOKED CREEK DEERING DIOMEDE EEK ELIM EMMONAK FORTUNA LEDGE CAMBELL GOLOVIN GOODNEWS BAY HOOPER LOWER KALSAG UPPER KALSAG KASIGLUK KIANA EITPNUK KIVALINA KOBUK KOTLIK KOTZEBUE KOYUK KWETHLUK KWIGILLINGOK LIME LITTLE DIOMEDE DEMOGRAPH Ics POPULAT- NUMBER ION FAMILIES 426 200 520 S27 225 85 320 180 3414 141 177 205 493 122 35 102 114 136 211 230 527 213 400 118 246 592 212 155 298 352 425 229 58 304 2500 156 444 185 35 90 63 30 37 82 50 19 = 7 35 658 23 a1 33 75 20 17 27 23 24 39 49 112 4g 76 26 43 73 43 37 46 55 67 44 15 51 592 27 a7 44 it 2= ELECTRICITY CAPACITY AVERAGE (KW) DEMAND (KW) 450 47S 420 1260 8400 810 206 231 775 215 535 150 7735 335 €50 510 4825 200 37 SS 22 134 2340 5S 31 31 86 49 91 32 100 47 71 45 we Ww ANNUAL CONSUMT, (MWH ) 765 484 190 1170 20499 482 271 272 757 425 739 284 ars 408 w wo w 10627 2eg AVEPAGE ANNUAL PRICE COST (8/KWH) (KS) 144 337 144 213 144 34 144 aa 386 125 5125 2! 144 212 144 119 ar 101 a7 280 144 187 144 as2 147 123 +44 385 144 180 144 0.40 248 144 173 oe 2763 144 127 S°da-1I REGIONAL DATABASE REGION 2 SUBASCT COAST DEMOGRAPHICS ELECTRICITY VILLAGE/ POPULAT- NUMBER CAPACITY AVERAGE ANNUAL AVEPAGE ANNUAL TOWN ION FAMILIES (KW) DEMAND CONSUMT. PRICE COST (KW) (MWH) ($/KWH) (FS) MEKORYUK 185 47 275 41 355 +44 156 MT. VILLAGE S21 84 650 127 Pata 44 439 NAPAIMUT NAPAK TAK 287 So 325 34 300 NAPASE TAK 167 47 34 NEWTOK 147 24 NIGHTMUTE 128 20 NOATAK 286 62 235 a7 411 44 isi NOME 2021 818 5885 1742 15261 NOORVIK Si4 94 760 80 698 144 307 OSCARVILLE 4? 12 PILOT STATION 311 S7 216 35 307 44 135 PITKA’S POINT g1 21 44 PLATINUM s7 25 QUINHAGAK 410 60 310 48 419 44 184 RED DEVIL 47 10 RUSSIAN MISSION 169 38 ST. MARYS 468 S53 144 ST. MICHAELS 220 48 340 37 326 +44 143 SAVOONGA 428 68 650 86 757 +44 333 SCAMMON BAY 212 34 125 32 282 +44 124 SELAWIK S26 94 650 78 679 +44 299 SHAKTOOLIK 165 31 200 24 209 +44 92 SHELDON’S POINT 119 22 SHISHMAREF 329 St 705 62 546 144 240 SHUNGNAK 184 38 705 45 390 +44 172 SLEETMUTE 124 23 STEBBINS 295 S2 150 28 248 44 109 STONY RIVER 82 16 TELLER 239 70 80 21 180 35 63 TOKSOOK BAY 310 49 375 48 423 +44 186 TULUKSAK 233 35 UNALAKEET s7s 138 1150 229 2002 39 781 WALES 127 36 260 15 129 44 57 WHITE MOUNTAIN 100 24 sases Sasssess saeceese Sueeases seseses= sscesses saesssss ssesss55 TOTAL 25516 5345 35268 7381 64642 15455 AVERAGE 345 72 928 194 1701 0.41 706 WT, AVERAGE 0.31 PER CAPITA DATA 5S 1.81 0.38 3.31 899 9°da-I PECIONAL DATAEA REGION 2 SUBARCT COAST VILLAGE/ TOWN AK TACHAK AKIAK AKOLMUIT ALAKANUK AMBLER ANDREAFSKI ANITAK ATMAUTLUAK BETHEL BREVIG MISSION BUCKLAND CANDLE CHEFORNAK CHEVAK CHUATHEALUK COUNCIL CROOKED CREEK DEERING DIOMEDE EEK ELIM EMMONAK FORTUNA LEDGE GAMBELL GOLOVIN GOODNEWS BAY HOOPER UPPER KALSAG LOWER KALSAG KASIGLUK KIANA KIPNUK KIVALINA KOBUK KOTLIK KOTZEBUE KOYUK KWETHLUK FWIGILLINGOK LIME LITTLE DIOMEDE MEK ORYUK MT. VILLAGE NAPAIMIUT in E DEMOGPAPH POPULAT- ION 426 200 520 52° 225 85 320 180 3414 141 177 205 493 122 as 102 114 136 211 230 537 213 400 118 246 592 212 155 298 332 425 229 538 304 2500 156 444 125 45 90 185 S21 Ics NUMEER FSMILJES 63 30 7 82 so 19 75 as 638 ai 0 WNNN | NN w WEaWNN OU b w 113 OIL ANNUAL AVEPA CONSUMPT. PRICE (GAL) ($/GA’ 60000 40000 30660 45260 409000 735000 12000 12045 58000 30000 80000 10000 23000 36000 14000 35200 25000 26000 130000 35000 109000 25000 20000 15900 60000 32700 40000 15000 1500000 35000 300090 78840 15090 40000 710000 400 SE Ly 1,89 1.89 1.40 1,84 1.63 1.89 1,65 1,69 1,89 2.15 1,89 1.73 ANNUAL, COST () 1123400 75600 126924 83462 65200 12a750 21970 124700 50400 74400 13600 42470 77400 31640 66522 49250 532000 293800 661590 219000 47250 372800 30051 1229000 613803 63200 28350 2250900 36000 56700 117174 30000 STOPACE CAPACITY (CAL) 000 00 24500 165000 319000 80000 7500 100000 81009 5000 5990 50900 1209000 090 49000 40000 aes RECIONAL DATAEASE REGION 2 SUBARCT COAST VILLAGE/ TOWN NAPAK LAK NAPASK I AK NEWTOK NIGHTMUTE NOATAK NOME NOORVIK OSCARVILLE PILOT STATION PITKA‘’S POINT PLATINUM QUINHAGAK RED DEVIL RUSSIAN MISSION ST. MARYS ST. MICHAELS SAVOONCA SCAMMON BAY SELAWIK SHAKTOOLIK SHELDON’S POINT SHISHMAREF SHUNGNAK SLEETMUTE STEBBINS STONY RIVER TELLER TOKSOOK BAY TULUKSAK UNALAKLEET WALES WHITE MOUNTAIN TOTAL AVERAGE WT. AVERAGE PER CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER 10N FAMILI ES 297 50 167 47 147 24 128 20 286 62 2071 818 514 94 47 12 S11 57 81 21 S7 25 410 60 47 10 169 38 462 53 220 48 422 68 212 34 526 94 165 31 119 22 329 51 184 38 124 23 295 52 82 16 239 70 310 43 233 35 575 138 127 36 100 24 siSeneac seneesna 25516 5345 345 72 5 OIL ANNUAL AVEPASE CONSUMPT. PRICE (GAL) (%/GAL) 50000 40000 1.89 20000 1,90 27000 1,89 14000 2.15 2.26 90000 1.89 10000 1.89 27000 1,89 7200 1,89 25000 1.89 50000 1.46 18230 1,89 30000 2.05 100000 1,89 40000 2.26 100000 1,86 30000 1.50 2.00 35000 20000 1.89 50000 1.95 40000 2.15 1,89 30000 2.26 1,89 25000 2.26 50000 1,89 25000 1.79 200000 lars 33000 2.25 20000 2.26 Ssssesss ssesses= 4202335 65661 1.89 1.73 228 ANNUAL CcOsT ($) 735600 38000 51030 30100 170100 18900 51030 13608 47250 73000 34455 61500 189000 90400 186000 45000 37800 97500 86000 67800 56500 94500 44750 350000 74250 45200 =s 7098745 =e 124129 385 STOPAGE CAPACITI (CAL) 49000 0 115000 20000 23720 360450 0 87000 14250 20000 30000 12000 200000 750000 181000 60400 243000 45000 10000 126900 31626 0 36200 49000 25000 342000 96360 35000 sessscss 6991421 110975 374 8°d-I REGIONAL DATABASE PEGION 2 SUBARCT CCAST DEMOGPAPHICS VILLAGE/ POPULAT- NUMBEP TOWN 10N FAMILIES AK TACHAK AK IAK AKOLMUIT ALAK ANUK AMBLER ANDPEAFSKI ANI AK ATMAUTLUAK BETHEL a BREVIG MISSION BUCKLAND CANDLE CHEF ORNAK CHEVAK CHUATHBALUK COUNCIL CROOKED CREEK DEERING DIOMEDE EEk ELIM EMMONAK FORTUNA LEDGE GAMEBELL GOLOVIN GOODNEWS BAY HOOPER UPPER KALSAG LOWER KALSAG KASIGLUK KIANA KIPNUF EIVALINA KOBUK KOTLIF KOTZEBUE 2 KOYUK KWETHLUK KWICILLINGOK LIME LITTLE DIOMEDE MEK ORYUK MT. VILLAGE NAPATMTUT 426 200 520 527 225 85 320 180 414 141 177 205 493 122 a5 102 114 136 211 230 537 213 400 118 246 592 212 155 298 332 425 229 58 a04 500 156 444 185 45 30 185 521 63 30 Br 82 50 19 73 35 658 23 a1 33 75 20 17 27 2 24 39 49 113 49 76 26 43 78 48 a7 46 55 67 44 15 51 592 27 87 44 11 25 47 a4 GASOLINE ANNUAL CONSUMPT. PRICE (GAL) 65000 20000 15000 28600 26009 30000 8300 13780 8000 4000 11000 10000 16000 17400 24550 45000 40000 16000 40000 10000 50000 20000 18000 313209 9000 30000 600090 20000 20000 76640 6000 43000 120000 659 ($/GAL) 2.00 2,00 1,55 2.13 2.14 2.00 2,40 1.71 2,00 130000 40000 23250 60918 55640 72000 14193 92250 100000 32000 79200 20000 100000 40000 43200 62600 21600 33100 900000 36000 40000 116493 12000 96000 240000 AVERAGE ANNUAL STCPACE COST CAPACITY ($) (GAL) €900 2500 15000 22000 24000 142000 50000 12900 42000 300c0 320000 4200 17500 22200 36900 6°a-1I REGIONAL DATABASE REGION 2 SUB4RCT CCAST VILLAGE/ TOWN NAPAIMIUT NAPAK TAK. NAPASK IAK NEWTOK NIGHTMUTE NOATAK NOME NOORVIK OSCARVILLE PILOT STATION PITKA’S POINT PLATINUM QUINHAGAK RED DEVIL RUSSIAN MISSION ST. MARYS ST. MICHAELS SAVOONGA SCAMMON BAY SELAWIK SHAK TOOLIK SHELDON’S POINT SHISHMAFEF SHUNGNAK SLEETMUTE STEBBINS STONY RIVER TELLER TOKSOOK BAY TULUF SAK UNALAKLEET WALES WHITE MOUNTAIN AVERAGE WT, AVERAGE PER CAPITA DATA DEMOGPAPHICS POPULAT- NUMBER ION FAMILIES 287 so 167 47 147 24 128 20 286 62 2021 818 Si4 94 47 12 Sil 7 81 21 37 25 410 60 47 10 169 38 468 sa 220 43 428 68 212 34 526 94 165 31 119 22 329 Si 184 38 124 23 295 S32 82 16 239 70 310 49 233 35 S73 138 127 36 100 GASOLINE ANNUAL AVERAGE = ANINUAL STOPPAGE CONSUMPT. PRICE COST CAPACITY (GAL) ($/GAL) ($) (GAL) 650 40000 2.00 80000 7000 35000 2.00 70000 25000 1.90 47500 10000 2000 2.00 4000 15000 2.40 12720 2.50 43000 1.90 81700 504590 9000 2.00 12000 15000 2.00 30000 20000 6000 2.00 12000 25000 2.00 50000 20000 20000 1.49 29800 12000 2.00 27000 2.25 60750 11000 20000 2,00 60000 71500 11000 2.50 27500 420000 63000 2.27 143010 65000 20000 1.70 34000 28000 1.95 62000 33000 22000 25000 2.00 50000 15000 2.50 34000 20000 2.40 468000 17800 2.00 20000 2,50 50000 21500 2,00 15000 2.50 37500 25000 2,00 50000 32000 25000 1,80 45000 25000 50000 1.78 89000 55000 16000 2.39 38240 1600 14500 2.44 35380 14000 2112720 3857622 2485120 25809 2,06 73840 44377 1.87 121 221 2 142 OT*d-1I REGIONAL DATABASE REGION 3 AK. PEN/ ALEUTS VILLAGE/ TOWN ADAK AKUTAN ATKA ATTU ISLAND BELKOFSKY CAPE SARICHEF COLD BAY DUTCH HARBOR FALSE PASS KING COVE NELSON LAGOON NIKOLSKI ST.GEORGE SAND PT. SQUAW HARBOR UNALASKA TOTAL AVERAGE WT. AVERAGE PER CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER TION FAMILIES 5000 615 Ati 18 92 21 23 14 225 a5 74 16 562 68 49 15 54 23 168 at 713 162 41 11 1184 204 aes a sai ee ae 8296 1233 638 95 7 ELECTRICITY CAPACITY AVERAGE ANNUAL DEMAND (KW) (KW) 1500 330 156 17 3250 582 1200 Lal 6106 1100 1527 275 2.81 0.51 2890 ($/KWH) 0.24 0.18 AVERAGE ANNUAL CONSUMPT. PRICE (MWH) COST (K$) 491 1.56 Tt°d-I REGIONAL DATABASE PEGION 3 AK. PEN/ ALEUTS VILLAGE/ TOWN ADAK AKUTAN ATKA ATTU ISLAND BELKOFSKY CAPE SARICHEF COLD BAY DUTCH HARBOR FALSE PASS KING COVE NELSON LAGOON NIKOLSKI ST.GEORGE SAND PT. SQUAW HARBOR UNALASKA TOTAL AVERAGE WT. AVERAGE PER CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER TION FAMILIES 5000 615 ttt 18 92 21 23 14 225 a5 74 16 562 68 49 15 54 23 168 at 713 162 41 11 1184 204 eaeeecec|saeneeee 8296 1233 638 95 7 OIL ANNUAL AVERAGE ANNUAL STORAGE CONSUMPT. PRICE COST CAPACITY (GAL) ($) ($) (GAL) 1.27 5000 8000 400000 400000 15000 304000 40000 2.18 30000 250000 300000 230759 200000 100000 100000 euzaress szensesn azcezens seeesass 995759 1587000 199152 1.73 144273 816 788 Cid REGIONAL DATABASE REGION 3 AK. PEN/ ALEUTS VILLAGE/ TOWN ADAK AKUTAN ATKA ATTU ISLAND BELKOFSEKY CAPE SARICHEF COLD BAY DUTCH HARBOR FALSE PASS KING COVE NELSON LAGOON NIKOLSK1 ST, GEORCE SAND PT. SQUAW HARBOR UNALASKA TOTAL AVERAGE WT. AVERAGE PER CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER TION FAMILIES 5000 615 111 18 92 21 23 14 225 35 74 16 S62 68 49 15 54 23 163 a1 7i3 162 41 11 1184 204 8296 1233 638 95 7 GASOLINE ANNUAL AVERAGE ANNUAL STORAGE COMSUMPT. PRICE (GAL) (%/GAL) 1,75 2.00 50000 0.90 5000 30000 0.86 53797 0.72 8000 0.72 COST CAPACITY (GAL) 5000 8000 45000 4000Q0 504000 40000 30000 25800 300000 38734 200000 5760 100000 146797 29359 1,16 0.81 120 115294 1587000 28823 176333 101 788 eT°a°r RECIONAL DATABASE REGION 4 S.W. COAST VILLAGE/ TOWN AKHIOF ALEKNAGIE CHIGNIE CHIGNIF LAGOON CHIGNIK LAKE CLAPKS PT DILLINGHAM EGEGIF EKUEK EKWOK IGIUGIG ILLIAMNA IVANOFF BAY KANAK ANAK KARLUK KING SALMON KODIAK KODIAK C.G.S. KOKHONAK KOLIGANEK LARSON BAY LEVELOCK MANOKOTAK NAKNEF NEW STUYAHOK NEWHALEN NONDALTON OUZINKIE OLD KARBOR PEDRO BAY PERRYVILLE PILOT PT. POPT HEIDEN PORT LIONS TOCIAK TWIN HILLS TOTAL AVEFACE WT. AVERAGE PEF CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER TION FAMILIES 111 18 227 34 78 43 80 47 118 19 83 21 1304 294 106 39 30 11 108 23 39 11 106 22 27 10 ss 35 99 29 4689 960 2776 570 93 16 143 23 122 33 89 23 255 40 321 S1 278 40 111 17 253 39 173 326 67 48 17 119 27 84 16 76 16 241 63 454 75 73 17 Seescses sseses== 13300 2766 380 81 wh ELECTRICITY CAPACITY AVERAGE ANNUAL DEMAND (KW) (KW) 2900 900 140 125 a1 26018 6774 550 22 3870 861 260 35 150 11 150 i 300 310 38 sso 65 sasczzces 35323 8748 2944 875 4,31 1.08 7890 59339 200 7538 303 100 100 ‘8 47 ($/KWH) 0.30 0.17 0.20 0.33 0.44 0,30 0.44 AVERAGE ANNUAL CONSUMPT. PRICE (MWH ) (KS) 2367 10083 40 2488 133 1,92 pT a°r REGIONAL DATABASE PESION 4 S.W, COAST VILLAGE/ TOWN AKHIOK ALEKNAGIK CHISNIK CHIGNIK LAGOON CHIGNIK LAKE CLAPES PT DILLINGHAM EGEGIK EKUF EKWOK IGIUGIG ILLIAMNA IVANOFF BAY KANAK ANAK KARLUK KING SALMON KODIAK KODIAK C.G.S. KOKHONAK KOLIGANEF LARSON BAY LEVELOCK MANOKOTAK NAKNEK NEW STUYTAHOK NEWHALEN NONDALTON OUZINKIE OLD HARBOR PEDRO BAY PERPYVILLE PILOT PT. POPT HEIDEN FORT LIONS TOCIAK TWIN HILLS TOTAL AVERAGE WT. AVERACE PEP CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER TION FAMILIES 111 18 227 34 78 43 80 47 118 19 8s 21 1304 294 106 39 30 11 108 23 39 11 106 22 27 10 ss 35 99 29 4689 960 2776 570 93 16 143 23 122 33 89 23 255 40 321 S1 278 40 111 17 253 39 173 326 67 438 17 119 er 84 16 76 16 241 63 13300 2766 380 81 Ss STORAGE CAPACITY (GAL) 1233855 71000 45000 550000 9800 2000000 3927000 1000 42000 150000 12000 30000 68000 40000 45000 32500 35000 250000 215000 OIL ANNUAL AVERAGE ANNUAL CONSUMPT. PRICE COST {GAL) ($) ($) 12000 1.43 17160 1.23 33000 1.23 40590 33000 Wier 41910 1.22 2625000 1.23 3228750 200000 1.46 292000 1.46 30000 1.23 36900 1,30 1.65 10000 1.60 16000 1.23 1.60 1.23 930000 1.29 1199700 18000 1.37 1.55 1.40 32000 1.35 43200 1.35 62000 1,23 76260 30000 1430 1.30 240000 1,65 396000 1.65 88293 1.36 120078 1.50 36000 1,23 44280 80000 307590 25000 4484293 263782 5583578 398827 420 8820655 420031 ST°a°I PEGIONAL DATABASE REGION 4 S.W. COAST AFHICK ALEKNAGIK CHIGNIK CHIGNIK LAGOON CHIGNIK LAKE CLARKS PT DILLINGHAM EGEGIk EKUK EKWOK IGIUGIG ILLIAMNA IVANOFF BAY KANAKANAK FARLUK KING SALMON KODIAK KODIAK C.G.S. KOKHONAK KOLIGANEK LARSON BAY LEVELOCK MANOKOTAK NAKNEK NEW STUYAHOK NEWHALEN NONDALTON OUZINKIE OLD HARBOR PEDRO BAY PERRYVILLE PILOT PT, PORT HEIDEN PORT LIONS TOGIAK TWIN HILLS TOTAL AVERAGE WT. AVERAGE PEP CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER TION FAMILIES 111 18 227 34 73 43 80 47 118 19 8s 21 1304 294 106 39 30 11 108 23 39 11 106 22 27 10 5S 35 99 29 4689 960 2776 570 93 16 143 23 122 33 89 23 255 40 321 Si 278 40 iit 17 253 39 173 326 67 48 17 119 27 84 16 76 16 241 63 454 753 73 17 Sesseses sasesess 13300 2766 380 81 a CASOLINE ANNUAL COMSUMPT. PRICE ($/GAL) (GAL) 12000 1360000 80000 12000 S500 134500 5000 5000 4500 25000 24000 50000 25000 5500 20000 10000 1778000 111125 275 AVERAGE ANNUAL STORAGE cOsT CAPACITY 87 0.60 1.30 0.60 95 1.41 1.55 75 ($) (GAL) 1183200 464492 8000 7200 275000 200000 3000 20000 4098 6345 5000 1214745 1069525 242949 71302 598 169 9T*a-I REGIONAL DATAEASE REGION 5 SOUTHCENTRAL DEMOGPAPHICS ELECTRICITY VILLAGE/ POPULAT- NUMEER CAPACITY AVERAGE ANNUAL AVERAGE ANNUAL TOWN 10N OF DEMAND CONSUMPT. PRICE cOsT FAMILIES (KW) (KW) (MWH) ($/KWH) (KS) ANCHORACE 210400 659644 220050 1927635 ANCHOR POINT 800 100 EIPCHWOOD 2040 +12 CHUGIAF 3224 12 CLEé™ GULCH a4 2t COHROE 20 COOPER LANDING 299 38 EAGLE RIVER 5400 +12 ELMENDOPF 6018 ENGLISH EAY Se 24 FIRE LAKE 475 +12 FORT RICHARDSON 8330 1205 CIPCDWOOD 144 KALIBUT COVE 30 27 HOMER 2227 367 HOFE Si 14 HOUSTON 408 79 EACHEMAK 211 19 KASILOF ie 20 KENAI S2c0 ENIK 19 +12 PALMER 43 17 +12 PORT GRAHAM 167 40 SEWARD 1914 587 5500 154 1350 TYONEK 282 74 TOTAL 249702 AVERAGE g9e3 246 0.12 WT. AVERAGE PER CAPITA DATA LT°d-1 REGIONAL DATABASE RECION S SOUJTHCENTRAL VILLAGE/ TOWN ANCHORAGE ANCHOR POINT BIRCHWOOD CRUGIAK CLAM GULCH COHOE COOFER LANDING EASLE FIVER ELMENDORF ENCLISH EBAY FIPE LAKE FORT RICHARDSON GIRDWOOD HALIBUT COVE HOMER’ HOPE HOUSTON KACHEMAK KASILOF KENAI KNIK PALMER FORT GRAHAM SEWARD TYONEK TOTAL AVERACE WT. AVERACE PER CAPITA DATA DEMOCRAPHICS POPULAT- NUMEER 10N OF FAMILIES 210400 200 100 3040 3224 a4 21 120 299 23 5490 6018 39 24 475 £3390 1805 144 30 27 227 367 Si 408 211 19 71 20 5200 10 45 17 167 40 1914 587 282 74 Sescsses= seeesecs 249702 9988 246 ANNUAL CONSUMPT. (GAL) PRICE {8/CAL) AVERACE ANNUAL COST ($) 20000 4000 21250 1,22 1.75 1.22 1,20 24400 7000 67100 200 1.35 26425 STORAGE CAPACITY (GAL) 10000 10000 23750 8T°d-I REGIONAL DATABASE PECION S SOUTHCENTRAL CASCLINE VILLAGE/ POPULAT- NUMBER ANNUAL AVERAGE ANNUAL STORAGE TOWN ION OF CONSUMPT. PRICE COST CAPACITY FAMILIES (GAL) ($/GAL, (3) (CAL) ANCHORAGE 210400 ANCHOR POINT 800 100 BIPCHWOOD 3040 CHUSIAK 3224 CLAM GULCH a4 21 COHOE 120 COSPER LANDING 239 98 EAGLE RIVER 5400 ELMENDORF 6018 ENCLISH BAY 29 24 FIRE LAKE 475 FORT RICHARDSON 2220 1805 GIPDWOOD 144 HALIEUT COVE 30 ba HOMER 2227 367 HOPE 51 HOUSTON 402 KACHEMAK 211 19 KASILOF 71 20 KENAI 5230 FNTIK 10 PALMER 48 17 POST GRAHAM 167 40 SEWARD 1914 587 TYONEK 282 74 24000 1.80 43200 24000 eee eee = TOTAL 249702 AVERAGE 3983 246 2-700 1,20 43200 24000 WT. AVERASE PEP CAPITA DATA 6T°d-1 REGIONAL DATABASE PEGION 6 FPRINCE WILLIAM SOUND VILLAGE/ TOWN CHISTOCHINA CHITINA COPPER CENTER CORDOVA EVaX G4SKONA CLENNALLEN GULY ANA METAFKLATLA TATITLEK VALDEZ WHITTIER TOTAL AVERAGE WT, AVERACE PER CAPITA DATA DEMOSPAPEICS POPULA- NUMBER TION FAMILIES 335 11 42 23 73 54 2780 415 493 12 363 109 5 16 a 1s 111 29 E169 298 282 113 Bessesss scsessce 10135 1095 845 100 CAPACITY AVERAGE ANNUAL DEMAND (KW) (KW) sco 31 60 2450 1855 €300 S12 750 17113 2796 Beesssss sesseces 4462 1304 2.91 ! CONSUMPT, (MW) 11432 5.05 AVERAGE ANNUAL PRICE cost ($/KWH) (ES) 22 5394 13 0.25 4486 1003 620 570 71 oz°d-I FECIONAL DATABASE PEGION 6 PRINCE WILLIAM SOUND “VILLAGE/ TOWN CHISTOCHINA CHITINA COPPER CENTER CORLOVA EYAK GAKONA GLENNALLEN CULKANA METARLATLA TATITLEK VALDEZ WHITTIER TOTAL AVEPACE WT, AVERACE PER CAPiT4S DATA DEMOGROPRICS POPULA- NUMBER TION FAMILIES 35 11 42 23 175 54 2780 415 3 49 12 263 109 ss 16 74 Ss 111 2 5150 298 288 115 10135 1095 845 100 ANNUAL AVEPACE ANNUAL STORAGE CONSUMPT. PRICE COST CAPACITY (CAL) ($) ($) (GAL) 1000 8000 1000 110000 25000 1,22 20500 25000 500000 50000 177667 37400 57 T@°d-1 REGIONAL DATABASE ON 6 CE WILLIGM OUND VILLACE/ TOWN CHISTOCHINA CHITINA CCfPER CENTER CCRDOVA ErAar GAFONS GLENNSLLEN GULEANA METARLATLA TATITLEK VALDEZ TOTAL AVERACE WT, AVERAGE PER CAPITA DATA DEMOGRAPHICS POPULA- NUMBER TION FAMILIES ro‘ & to th Se my ne NOT bh Oe RUwDUOWMOUNW 1 61 GASOLINE ANNUAL AVERAGE ANNUAL STORAGE CONSUMPT. PRICE cost CAPACITY (GAL) ($/GAL) ($) (GAL) 1,30 100000 10000 Beseesss sseseess sesscese seeeases 27° a-1 DEMOGRAPHICS LECTRICITY VILLAGE/ FOPULAT- NUMBER ANNUAL AVERAGE ANNUAL TOWN ION OF CONSUMPT. PRICE cesT MWR) (S/KWH) iK#) EIG DELTA 390 20 +25 CANTWELL 7 24 CHICKEN 20 CLEAR 50 25 COLLECE 3643 941 DELTA JUNCTION $29 301 +25 BOT LAKE 8 16 225 23 200 19 38000 EASLE 0g 25 EACLE VILLAGE 45 19 ¢ 264 82 226091 48974 425011 10751 FCST WAINWRIGHT 5553 HESLY r9 21 +16 NENANA 450 143 2 NOPTHWAY 201 16 420 137 1290 +21 252000 TANACROSS 144 33 TETLIN 118 31 90 TOK 631 205 220 729 6287 e190 1212550 sssesscss Saescsss= sssczssc TOTAL 23164 1927 AVERAGE 1363 121 57833 12466 109200 0.21 501177 WT. AVERAGE PER CAPITA DATA 1 O17 1.51 0.50 £f G-7 OREGICNAL DATAEASE REGION 7 FAIREANKS, ALASKA HIGHWAY TOWN BIC DELTA CANTWELL CHICKEN CLEAR COLLESE DELTA JUNCTION DOT LAKE EAGLE ESCLE VILLAGE ESTEP FATPEANES FORT GREELY FORT WAINWRIGHT HEALY NENANA NORTHWAY TANACROSS TETLIN TOK TOTAL AVERACE WT. AVERAGE PER CAPITA DATA DEMOGRAPHICS POPULAT- NUMBER 10N OF FAMILI 23164 1 ES 20 24 30 25 S41 301 16 25 18 oD 21 143 16 33 31 205 937 121 ANNUAL AVERACE ANNUAL CONSUMPT, PRICE cost (GAL) (S/GAL) (€) 1.7) 1.75 1.75 7S 1.75 15000 1.75 1.75 1.75 1.75 26250 STORACE CAP4CITY (GAL) 1500 1500 200000 1000¢ 210000 1000 70667 0.14 ve G1 VILLAGE/ TOWN EIG DELTA CANTWELL CHICKEN CLEAR COLLECE DELTA JUNCTION DOT LAKE EACLE EAGLE VILLACE EST FAI NES FOPT GREELY FOFT WAINWRIGHT HESLY RENANA NORTCWAY TANACROSS TETLIN TOK TOTAL AVERAGE WT, AVERAGE PEP CAPITA DATA POPULAT- NUMZEP ION OF FAMILI fae en ao tase meee w - wm Mpont) bUMWODS bo ES 20 24 30 aa 941 301 16 a 18 82 ome hh Ch 10 OD hy GASOLINE SNNUSL CONSUMPT,. (SAL) 8000 AVEPSGE PRICE (3/GAL) 2.25 2,25 2.25 2.25 2,2 2.2 209 2.2 2.25 2:25 ANNUAL COST ($) 18000 STOPSGCE CAPACITY (CAL) 35000 6000 20500 0.01 St°d-1I REGIONAL DATABASE PEGION & INTERIOR VILLAGE/ POPULA- NUMSER TOWN TION FAMILIES ALATNA ALLAKAKET 176 38 ANDERSON S02 120 ANVIK 94 7 ARCTIC VILLAGE 122 33 BEAVER ee 29 EETTLES 49 15 CENTRAL 23 19 CIRCLE 52 22 FT. YUKON 665 141 GALENA 696 163 GRAYLING 161 38 HOLY CROSS 265 56 HUGHES 97 18 HUSLIA 219 49 KALTAS 245 49 KOYUKUK 122 26 LAKE MINCHUMINA 22 LIVENGOOD 80 25 MANLEY HOT SPRINGS 65 44 MCGRATH 333 108 MEDFRA 2t 8 MINTO 199 48 NIKOLAI 103 25 NULATO 352 Si RAMPART 59 18 RUBY 197 50 SHACELUK 186 438 STEVENS VILLAGE 73 235 TAKOTNA 45 14 TANANA 486 66 TELIDA 29 12 VENETIE 155 29 gecssesss gusscss= sazsasa TOTAL 5981 1419 AVERAGE 187 46 WEIGHTED AVERAGE PER CAPITA DATA 4 AVERAGE ANNUAL cost (KS) 66 4059 S57 88 135 118 160 54 562 91 218 84 584 6774 S21 ELECTRICITY CAPACITY AVERAGE ANNUAL DEMAND CONSUMT. PRICE (KW) (KW) (MWH) ($/KWH) +16 150 18 160 41 600 122 10970 +37 +32 1035 199 1740 +32 175 23 200 144 160 35 306 +44 285 31 269 +44 455 41 363 +44 130 22 190 130 17 145 +37 1850 229 2007 +28 215 24 206 044 550 57 496 +44 150 22 191 +44 1650 202 1769 33 wenecss= saseesss sessszss sssezsss 7535 1042 19012 538 74 1358 0.38 0.36 2.26 0.31 5.69 3.10 97° d-1I REGIONAL DATABASE RECION 8 INTERIOR OIL VILLAGE/ POPULA- NUMEER ANNUAL AVERAGE ANNUAL STORAGE TOWN TION FAMILIES COMSUMT, PRICE cost CAFACITY (GAL) ($) ($) (GAL) ALATNS ALLAKAKET 176 28 3720 1.75 10010 18000 ANDERSON S02 120 1.75 ANVIK 94 27 1.75 12000 ARCTIC VILLAGE 122 22 5000 1.75 8750 30000 EEAVER 83 29 2000 1.75 5250 EETTLES 49 15 7s CENTRAL 23 19 CIRCLE S52 22 1.75 FT. YUKON 665 141 314651 1.75 550639 287130 GALENA4 696 168 Len 550000 GRAYLING 161 a3 1.75 8900 HOLY CROSS 265 56 1.85 135000 HUGHES 97 18 4000 1.75 7000 10000 HUSLIA 219 49 1.75 2900 KALTAG 245 43 1.75 8900 KOYUKUK 122 26 6000 1,93 11580 11000 LAKE MINCHUMINA 22 LIVENGOOD 20 25 MANLEY HOT SPRINGS es 44 7000 1.75 12250 25000 MCGRATH 333 108 60000 1.70 102000 566000 MEDFRA 2 8 MINTO 199 48 50000 10000 NIKOLAI 103 25 2400 2.19 5232 2000 NULATO 352 Si 25000 1.75 43750 15000 RAMPART 39 18 1.75 RUBY 197 So 75000 1.79 134250 112000 SHAGELUK 196 48 12000 2,30 27600 16000 STEVENS VILLAGE 73 2 1855 22100 TAKOTNA 45 2.25 9500 TANANA 426 1.75 26000 TELIDA 29 1.75 5000 2000 VENETIE 155 TOTAL 5981 1419 576626 918311 1900630 AVERAGE 187 46 38442 1,82 69964 86392 WEIGHTED AVERAGE 1,77 PER CAPITA DATA 4 809 1503 1651 LC aat REGIONAL DATABASE RECION 8 INTERIOR VILLAGE/ POPULA- NUMBER TOWN TION FAMILIES ALATNA ALLAKAKET 176 38 ANDERSON 502 120 ANVIK 94 27 ARCTIC VILLAGE 122 35 BEAVER 28 293 BETTLES 49 15 CENTP4L 23 TS: CIRCLE 52 22 FT. YUKON 665 141 GALENA 696 168 GRAYLING 161 28 HOLY CROSS 265 56 HUGHES 97 18 HUSLIA 219 49 KALTAG 245 49 KOYUKUK 122 26 LAKE MINCHUMINA 22 LIVENGOOD 20 25 MANLEY HOT SPRINGS 65 44 MCGRATH 333 108 MEDFRA 21 8 MINTO 199 43 NIKOLAI 103 25 NULATO 352 51 RAMPART 59 18 RUBY 197 50 SHAGELUK 186 48 STEVENS VILLAGE 73 25 TAKOTNA 45 14 TANANA 486 66 TELIA 29 12 VENETIE 155 29 cescanccs ==ssen== TOTAL 5981 1419 AVERAGE 187 46 WEIGHTED AVERAGE PER CAPITA DATA GASOLINE ANNUAL AVERAGE ANNUAL CONSUMT. PRICE COST (GAL) ($) ($) STORAGE CAPACITY (GAL) 11000 2.25 2.25 2.25 10000 2,25 11000 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.2 2.25 2.00 2.25 20000 2.78 50000 25000 2.25 15000 2.25 37500 1.95 2.85 1.7 1,25 5000 1.25 <saadeee_seaae=e= 184500 20500 2.17 2.21 477 24750 22500 24750 S5600 56250 33750 73125 6250 296975 44414 876 18000 1000 49212 200000 12000 25000 27900 22000 10000 10000 15000 37500 8000 3000 438612 31329 505 87° d-I REGIONAL DATABASE= FES VILLAGE/ POPULAT- NUMBEP CAPACITY AVERAGE ANNUAL AVERAGE ANNUAL TOWN ION OF DEMAND CONSUMPT, PRICE COST FAMILIES (XW) (KW) (MWH) ($/KWH) (KS) ON 499 a4 129 1050 a4 357 ANNETTE 135 ss AUKE BAY 934 7 PELL ISLAND EIOPYA ISLAND CAFE POLE a <6 CLOVEP PASS 1 ma) CRAIG S27 17 1015 256 2227 19 442 DILCLAS 269 h 112 29 32 24 vs 4200 294 7C40 +24 1590 = 183 5108 2a4 2e75 35 Sot 3 67 449 113 o34 21 209 35 23 207380 17270 +07 10590 710 123 1E0C 22! 35 679 44 12 199 3 35 26 1695 9615 05 KLAWOCE S15 62 1650 LPF 635 543 ELUFWAN 13% 45 6S 29 KUPF EANOF 4> 13 METLSF ATLA 1143 245 63500 185 1618 PELICAN 167 65 1200 276 2516 0.10 242 2820 811 9200 2337 2047: 63 16 245 50 +94 6073 108 4059 846 250 ell 624 123 35 3250 74 14 1736 aga 5 22 grt TOTAL 60681 3994 AVEPAGE 1957 148 2261 2108 13462 0.20 1812 WT. AVERAGE PER CAPITA DATA 2,63 0.70 n ar a 0.51 67° a-I RECGICNAL DATAEASE PESION 9 SOJTHEAST VILLAGE/ TOWN ANGOON ANNETTE AUFE BAY FELL ISLAND FIOPKA ISLAND CAPE FOLE CLOVER P4SS CRAIG DOUGLAS EDNA Bay ELFIN COVE FRITZ COVE CUSTAVUS HAINES HOONAK HYDAFURG HYDER JUNEAU KARE KASAAN KETCHIKAN KLAWOCK KLUE WAN KUPFEANOF METLAKATLA PELICAN PETERSEURG PT. ALEXANDER SAXMAN SITKA Sr AGWAT TENAKEE SPRINGS WPANGELL WT. AVERAGE PER CAPITA DATA PCPULAT- NUMBER 10N OF FAMILIES 4938 g4 195 55 994 75 123 26 261 75 S27 117, 1220 112 20 33 24 1892 S75 936 123 379 67 35 23 20780 r10 123 44 13 16085 315 62 iat 45 47 13 liag 245 167 65 2829 S11 63 16 245 50 607 846 250 123 85 3250 754 484 7 60681 3994 1957 148 ANNUAL CONSUMPT. (SAL) 600000 430000 30000 706000 60000 PRICE ($/GAL) 1.44 eee Oon ww nnNno Nh wo to eee fn aw uo NN Nh - uh 1,33 ($) AVERAGE ANNUAL cost STORACE CAPACITY (GAL) 169000 25000 1000000 20000 50000 0 1300000 50900 550000 321800 REGIONAL DATABASE PECION 9 CUTHEAST VILLAGE/ ANNUAL AVERAGE ANNUAL STORAGE TOWN 10N OF CONSUMPT. FRICE cost CAPACITY FAMILIES (GAL) {S$/CAL) ($) (CAL) ANGOON 493 a4 1.56 18009 ANNETTE 1395 SQ AUFE BAY 994 75 BELL ISLAND BIORPSA ISLAND CAPE POLE 123 26 CLOVER PASS 261 ri CRAIS S27 117 1.76 40000 DOUGLAS 1260 112 20 39 24 1.56 25000 72 26 1.70 19g2 S75 659000 650000 925 183 1.56 37 67 1,56 10000 5 2 20780 < 710 123 120000 1,55 17000 FASASN 44 13 1,56 KETCHIKAN 16085 ELAWOCK 315 €2 1.52 KLUY WAN 131 45 1.56 KIJPPEANOF 47 13 1.56 METLAKATLA 1149 245 1,80 FELICAN 167 5 1,52 PETEPSEURG 282) Sit PT. ALEXANDER 63 16 1,55 SAXMAN 245 $0 1,60 SITKA 6079 SKAGWAY 345 250 242600 TENAKEE SPRINGS 123 85 10000 1.56 WPANCELL 32¢ 734 YAKUTAT 76 200000 TOTAL 60581 3994 AVERAGE 1957 148 244520 1.59 97556 WT. AVERAGE PER CAPITA DATA APPENDIX I-C HISTORICAL TRENDS IN MOTOR VEHICLE FUEL CONSUMPTION CONSUMPTION OF MOTOR VEHICLE FUELS: azasxa ‘) (Million Gallons)!?) (7) 1977 1978 1979 1980 1981E Aviation ace Taxable.) 103.163 113.006 126.190 130.074 132.840 Exempt 190. 392 220.789 220.988 190.881 1517672 Aviation - Gas Taxabl¢, >) 15.249 15.145 16.373 16. 354 17.962 Exempt 7.521 - 685 ~552 - 558 - 636 Aviation Bondea ‘©) Exempt 37.189 29.812 67.986 95.229 116.058 Highway - Gas Taxable, 5) 18t.119 179.069 173.802 169.191 177.088 Exempt 5.094 8.290 7.527 8.162 9.023 Highway - Diesel Taxable (15) 118.999 101.598 565997 64.791 135.541 Exempt 45.162 54.050 39.477 23.935 21.902 Highway - Other Taxable (2) (2) 91.562 116.897 74.878 off Highway )~ Diesel Exempt (2) (2) 81.483 97.004 103.226 Marine - Gas Taxable, 3) 6.059 7.160 8.004 7.573 7.574 Exempt 384 -554 ~292 -025 -091 Marine - Deisel Taxable, ,) 32.217 41.869 53.167 62.341 70.298 Exempt 6.396 10.116 6.325 5.370 5.168 Marine - Non-propulsion Exempt a.823 (2) (2) (2) (2) other (8) Taxable -593 29.228 - 258 -020 -002 Exempt -998 (2) (2) (2) (2) CONSUMPTION OF MOTOR VEHICLE PURGES: (Million Gallons) Aviation 7 ,Jet 4 rexabige’) Exempt Aviation - Gas Taxabl 2 Exempt (2 ) 6 Aviation Bonded ' ) Exempt Highway - Gas Taxabl¢, >) Exempt Highway - Diesel Taxabl Exempt (20) Highway - Other Taxable Off High - Diesel exempt OL) Marine - Gas Taxabl Exempt (22) Marine - Diesel Taxabl Exempt (22) Marine - Non-propulsion Exempt other ‘8) Taxable Exempt Loi: 83.555 (3) 10.413 (3) 37.189 74.742 (3) (2) (2) 3.826 (3) 20.826 (3) 3.823 359 (3) 1978 91.783 (3) 10.370 (3) (2) 140. 250 (3) 77.989 (3) (2) (2) 3.887 (3) 28.291 (3) (2) 25.001 (2) I-C.2 1979 1023555 189.785 11.339 453 78.741 46.690 4.614 3S 36.913 4.997 (2) -063 (2) RAILBELT +) 106.451 163.754 11.242 345 957229) 128.190 6.276 17.666 10.738 100.528 51.505 4.459 -031 43.871 4.517 (2) -050 (2) 107.852 129.852 12.432 - 343 134.051 73053) D3 1225) 11.378 64. 393 48.677 4.652 -025 50.314 4,292 (2) -001 (2) CONSUMPTION Aviation 7 ,Jet raxabige®) Exempt Aviation - Gas Taxabl Exempt 2) Aviation Bonded ‘©) Exempt Highway - Gas Taxabl exempt 2) Highway - Diesel Taxabl Exempt (20) Highway - Other Taxable. Off High - Diesel exempt tL) Marine - Gas Taxabl Exempt (3) Marine - Diesel Taxabl ae Marine - Non-propulsion Exempt other (8) Taxable Exempt OF MOTOR VEHICLE FUELS: (Million Gallons) Load 1978 4.765 5-167 (3) (3) 1.852 1.543 (3) (3) (2) (2) 14.102 L4c731 (3) (()) 10.746 Sol (3) (3) (2) (2) (2) (2) 2.135 2.128 (3) (3) 7.707 Sor) (3) (3) -667 (2) -131 39) (3) (2) I-c.3 LOT 4.914 +226 aD 023 (2) B we Ww @ wo on 6.578 5.660 -002 20.157 2.075 -103 9.888 - 498 (2) 734 (2) soutuEast'?) 3.760 Sue i 72 eS (2) 14.612 oO W203 6.144 - 003 26.192 1.739 -.011 10.569 melee (2) -.045 (2) 10.202 6.505 -O01 S805 1.634 -061 10.814 -178 (2) +002 (2) CONSUMPTION OF MOTOR VEHICLE FURGS: (Million Gallons) 1977 Aviation Tayet 14.844 Taxable, ) Exempt (3) Aviation - Gas Taxabl 2.984 2 came (3) 6 Aviation Bonded ' ) Exempt (2) Highway - Gas Taxabl 25.994 Exempt (2) (3) Highway - Diesel Taxabl 332516 expel”) (3) Highway - Other Taxable (2) Off High’ - Diesel exempt!) (2) Marine - Gas Taxabl -690 Exempt (3) (3) Marine - Diesel Taxabl 3.684 Exempt (22) (3) Marine - Non-propulsion Exempt - 833 other (8) Taxable eel OU Exempt (3) See footnotes which follow tables. 1978 16.057 (3) 3.232 (3) (2) 24.688 (3) 17.878 (3) (2) (2) 1.144 (3) 4.804 (3) (2) 4.089 (2) I-c.4 1979 18.691 30.977 Sere, -075 (2) 26.675 1.146 23.462 9.801 12.819 14.635 1.316 053 6.366 -830 (2) -061 (2) (1) REST-OF-STATE 1980 19.863 26.750 3.400 -099 (2) 26.389 1.316 39.833 7.053 16.366 19.307 1.375 -005 7.902 742 (2) 015 (2) igeiz‘”? 19.933 21.247 3.638 PL 59 (2) 27.697 1.300 72.114 4.018 10.483 16.664 1.288 -004 9.169 -699 (2) - 000 (2) (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) Source: FOOTNOTES Data were developed from Judicial District reports and reallocated according to the following procedure: Southeast = Judicial District I i Railbelt Population Share x (Judicial District III + Judicial District IV) Rest-of-State = (Judicial District III + Judicial District Iv) - Railbelt + Judicial District II Data were not reported for that year. Data were not reported by Judicial District. Civilian domestic operations. Military and international operations utilizing domestic fuel. International operations utilizing foreign fuel. Estimate for the year based on first nine months. Other is essentially a type of diesel. For purposes of conversion: 1 gallon gasoline = .0215 barrel crude oil equivalent 1 barrel gasoline = 5.248 million Btu 1 gallon diesel = .0239 barrel crude oil equivalent 1 barrel diesel = 5.825 million Btu 1 gallon jet fuel = .023 barrel crude oil equivalent 1 barrel jet fuel = 5.604 million Btu Military, government, and electric utility power generation. Off-highway diesel is diesel sold for space heating and power generation. There is no requirement to report this information, so voluntary reported data shown may understate actual use figures. Military and government. Military, government, and non-propulsion. Alaska Department of Revenue, Motor Fuel Tax Return Worksheets. T-¢ > This appendix summarizes demographic, physical, and economic information about each of the nine regions. The population figures are based on census data from, Alaska 1980 Population: A Preliminary Look, Alaska Department of Labor, 1981. Employment data comes from four statistical quarterlies published in 1979 by the Alaska Department of Labor. The 29 census divisions used by the Labor Department fit the nine regions well, with the exception of the Subartic Coast and the Interior where judgement was used to allocate statistics from overlapping census divisions. The employment figures do not include military employment. Physical statistics are taken from the Alaska Regional Profile series published for the Office of the Governor by the joint Federal/State Land Use Planning Commission. ENERGY PLANNING REGIONS BARROW w! js / _t \ / / KOTZEBUE AC a / a SU Sf \oe ) ws ! 4 | - J a DQ Il | INTERIOR Fainsanks WHI. “atin SUBARCTIC 7 oo oF IRBANKS/ c A N A DA COAST. f " S é NCHORAG OS Fo i pued | at iT r PRINCE f oittincnam J point ia ~~ £X. \ JUNEAU ° II. SOUTHWEST ' SITKA™ ALEUTIAN Is. \ COAST Osos sournt aN ALASKA PEN. fo Cen NUR TCHI “o Conversion Factors ENERGY FORM STANDARD UNITS —_ BTU EQUIVALENT ¢ Electricity —Capacity KW (Kilowatt) MW (Megawatt) — Generation KWH (Kilowatt hour) 3,412 MWH (Megawatt hour) 3,412,000 * Oil —Crude oil bbl (barrel) 5,800,000 gal (gallon) 138,095 — Diesel fuel bbl 5,825,000 gal 138,690 — Distillate fuel oil bbl 5,825,000 gal 138,690 — Motor gasoline bbl 5,253,000 gal 125;070)))) ing —Aviation gasoline bbl 5,048,000 gal 120,190 —Jet fuel bbl I gal — Kerosene bbl 5,670,000 gal 149,690 —LPG (liquified bbl 4,011,000 petroleum gas) gal 95,500 —Lubricants bbl 6,065,000 gal 144,400 —Resid. (residual bbl 6,287,000 fuel oil) gal 149,690 * Coal —Alaskan coal Short ton (2000 Ibs) 16,440,000 MASEL GALA COU Ib We 8,220 —Domestic anthracite Short ton 23,250,000 Ib 11,760 —Domestic Shortton 22,430,000 bituminous Ib 1215 ¢ Natural gas SCF (Standard cubic foot) 1,020 UT MCE (Thousand cubic feet) 1,020,000 * Peat __—Alaskan Peat PRUNE HULL il ll Ml WL 6,000 —9,000_ ¢ Wood —Sitka Spruce cord 17,100,000 Source: The Energy Factbook, Congressional Research Service, Library of Congress. ¢ Appendix R5 DEPD-82-530