Loading...
HomeMy WebLinkAboutKoyuk Coal 1983Koyuk LITHOLOGIC LOG OF CUTTINGS on HOLE NO. DH-K1-83 . company C. C. Hawley & Associates, Inc. ADDRESS PROJECTNO. 738 NW Coal STARTED 9/1/83 ' pace 1 of 1 compteTeD 9/1/83 CONTRACTOR Thrasher & Associates ELECTRICLOGS BPB LOGGED BY SAMPLES DESCRIBED BY Tony Van der Poel PO TO_ 142 ‘DIAM. 4 3/4 LOCATION: sec. Koyuk T R MERIDIAN FLuio_ Air ii COUNTY STATE /Alcaka COLLAR ELEV. KORTH COORD. EAST COORD. As DRILLER: Andy Thrasher PERE goady silts ~ silky somis, Ite dk grey. coa| of lignite, glock, silky sods We RETORAD, SON DRILL RAE, Rcwaove Koyuk LITHOLOGIC LOG OF CUTTINGS ‘| HOLENO. _DH-K2-83__. PAGE] of J company C. C. Hawley & Associates, Inc. ADDRESS prosectno, 738 NW Coal STARTED 9/2783 COMPLETED * CONTRACTOR Thrasher & Associates _ELECTRICLOGS BPB LOGGEDBY Gregg Stowe SAMPLES DESCRIBED BY Tony Van der Poel PD TD _180 DIAM. 4 3/4 LOCATION: SEC. _ Koyuk T R MERIDIAN FLuin__Air 1 | COUNTY STATE Alaska COLLAR ELEV. WORTH COORD. EAST COORD. Ae ORILLER: Andy Thrasher loc. H-dk qney sants € silts. block coal. Bresanve Koyuk LITHOLOGIC LOG OF CUTTINGS *. HOLENO, DH-K3-83 PAGE 1 of J COMPANY _C. C. Hawley & Associates, Inc ADDRESS prROJecTNO. 738 NW Coal STARTED 9/2/83 COMPLETED ~ contractor !hrasher & Associates e.ectrictocs BPB LOGGEDBY Gregg Stowe SAMPLES DESCRIBED BY PD 140 TD_150 ‘DIAM. 4 3/4 LOCATION: SEC. _Koyuk T R MERIDIAN FLUID_ Air HA COUNTY STATE Alaska COLLAR ELEV. NORTH COORD. EAST COORD. Ae ORILLER: Andy Thrasher 0 05's 110 -— San \ Silts Ligh Grey) 115 120 30 135) 140 145 150 Rewaove Koyuk LITHOLOGIC LOG OF CUTTINGS * woveno, DH-K4-83 pace | of 1 COMPANY C. C. Hawley & Associates, Inc. ADDRESS PROJECTNO. 738 NW Coal sTarTeD 9/2/83 compLeTeO «9/2/83 contractor Lhrasher & Associates evectric tos BPB Loccepsy Gregg Stowe SAMPLES DESCRIBED BY__' Tony Van der Poel PD 104 TD_105 DIAM. 4 3/4 LOCATION: SEC. Koyuk T R MERIDIAN Fluip_ Air COUNTY STATE Alaska COLLAR ELEV. NORTH COORG. EAST COORD. A+ ORILLER: Andy Thrasher Coll 60% ice 40% oeak silt 90 95 105] -.- 110 115 120 125 130 as qa abackeé — val Sandy ii- med a” Siey Sand § sandy si si 8d REMARKS Koyuk LITHOLOGIC LOG OF CUTTINGS *. HOLENO. DH-K5-83 PAGE 1 of 1 company C+ C. Hawley & Associates, Inc. appress ii PROJECTNO. 738 NW Coal STARTED 9/2/83 COMPLETED 9/2/83 CONTRACTOR Thrasher & Associates _ ELECTRIC LOGS BPB LOGGEDBY Gregg Stowe SAMPLES DESCRIBED BY__Tony Van der Poel PD to. 135 pram. 4 3/4 LOCATION: SEC. Koyuk T R MERIDIAN FLUID_ Air Lt COUNTY STATE Alaska COLLAR ELEV. NORTH COORD. EAST CODRD. Al 80 Ace, lt. brown Silt 95 Slow drill rate 20% Carbonate Cement fe qe silty sand Acace shell froanents 110 Med - Fishy 5s Silt § silty “sand 115 120 Arace Coal Black doy Mi ite (2) Ae ep aye 2 135 Med omy é lt Browa ray Silty Sand erianve ee » rian” Koyuk LITHOLOGIC LOG OF CUTTINGS “HOLE NO. DH-K6-83 | PAGE 1 of 1 COMPANY C, C, Hawley & Associates, Inc, ADDRESS PROJECTNO. 738 NW Coal STARTED 9/3/83 COMPLETED - CONTRACTOR Thrasher & Associates ELECTRIC LOGS BPB LOGGED BY Gregg Stowe SAMPLES DESCRIBED BY ___LOny Van der Poel PO to 94 piam.__ 4 3/4 LOCATION: SEC. Koyuk T R MERIDIAN FLUID Ady i 4 COUNTY STATE Alaska COLLAR ELEV. NORTH COORD. EAST COORD. A+ DRILLER: Andy Thrasher ‘ollg 50h Tce . 50% Brown Peat Le-Med Cres sandy o silt ¢ _ Sand 20% Seft, black coal Trace Vitreous coal Koyuk LITHOLOGIC LOG OF CUTTINGS ‘| HOLENO, DH-K7-83 PAGE 1 of 1 COMPANY ADDRESS PROJECTNO. 738 NW Coal STARTED ae ‘9/3/83. 3 COMPLETED ~ alae CONTRACTOR Thrasher & Associates ELECTRIC LOGS LOGGED BY regg Stowe SAMPLES DESCRIBED BY _‘ Tony Van der Poel PD to 118 optam._4 Te LOCATION: SEC. Koyuk T R MERIDIAN Fluip Air it COUNTY STATE Alaska _ COLLAR ELEV. NORTH COORD. EAST COORD. B+ Pip 2 ANadl dk bes shale Slows Dkote : Rcwagre oe Y vary Koyuk LITHOLOGIC LOG OF CUTTINGS * HOLENO. DH-K8-83_.. PAGE 1 of 1 company C. C. Hawley & Associates, Inc. ADDRESS PROJECTNO. 738 NW Coal STARTED 9/3/83 comeceteo 9/3/83 CONTRACTOR Thrasher & Associates _ ELECTRIC LOGS BPB LOGGEDBY Gregg Stowe SAMPLES DESCRIBED BY Tony Van der Poel PD To__120 o1AM. 4 3/4 LOCATION: sec, __ Koyuk T R MERIDIAN ss FL. AG COUNTY STATE Alaska COLLAR ELEV. KORTH COORD. EAST COORD. Ay pritteR: Andy Thrasher ray <sond Ndrote, “My 110 > ae 115 120 125 130 135 140 145 150 Koyuk LITHOLOGIC LOG OF CUTTINGS “* HOLENO, DH-K9-83__. PAGE 1 of 1 COMPANY __C, C, Hawley & Associates, Inc, ADDRESS PROJECTNO. 738 NW Coal STARTED "9/3/83 COMPLETED _ a CONTRACTOR Thrasher & Associates ELECTRIC LOGS BPB LOGGED BY regg Stowe SAMPLES DESCRIBED BY Tony Van dex Poel Po To_ 60 pam. 4 3/4 LOCATION: SEC. Koyuk R MERIDIAN FLUID air COUNTY res Alaska COLLARELEV, KORTH COORD. EAST COORD. A 85 90 95 Koyuk LITHOLOGIC LOG OF CUTTINGS * woLeno, DH-K10-83 pace 1 of 1 company C. C. Hawley & Associates Jnc. ADDRESS prosectno, 738 NW Coal starten 9/3/83 2:53 COMPLETED — 9/3/83 3:38 CONTRACTOR Thrasher & Associate¢LECTRIC LOGS Loccepsy Gregg Stowe SAMPLES DESCRIBED BY _- Tony Van der Poel PD to 140 DIAM. 4 3/4 Location: sec. Koyuk T R MERIDIAN Fluio_ Air eae COUNTY state Alaska COLLAR ELEV. MORTH COORD. EAST COORD. Be ORILLER: Andy Thrasher ollfr | 1BO% Lr gray sondy silt WH M. 5 Kus sike - Lt qrey silty sand td silt SI trace ee 105 -110 | 10% coal, shale - ae gre claye . runs ih ae a= fo fa 120 F 125 gies 130 |." , Lt tI Sandy stk it) ~~ ait, 140 80" Bemaove Koyuk LITHOLOGIC LOG OF CUTTINGS * HOLENO. pa-K11-83 company C. C. Hawley & Associates, Inc. ADDRESS PROJECTNO. 738 NW Coal STARTED _ 9/3/83 4:08 CONTRACTOR Thrasher & Associates ELECTRICLOGS BPB pace | of 1 compteTeD ~ 9/3/83 toccepsy Gregg Stowe SAMPLES DESCRIBED BY Tony Van. der Poel PO Tse = MOI Aus LOCATION: SEC. Koyuk T R MERIDIAN COUNTY state Alaska COLLAR ELEV. NORTH COORD. EAST COORD. a DRILLER: Andy Thrasher Pcwacve Koyuk LITHOLOGIC LOG OF CUTTINGS “HOLE NO. CH-K12-83 | PAGE 1 of 1 COMPANY C. C. Hawley & Associates, Inc, ADDRESS PROJECT NO. 738 NW Coal sTARTED 4/9/83 9:35 COMPLETED “4/9/83 5:10 conTRactorthrasher & Associates ELECTRICLOGS — BPB LOGGED BY Gregg Stowe SAMPLES DESCRIBED BY Tony Van der Poel PD to 35er pam, 4 3/4 LOCATION: SEC. Koyuk 7 R MERIDIAN FLUID Air Li COUNTY STATE Alaska COLLAR ELEV. MORTHCOORD. =————__sSEAST COORD. Se eee {tL} ORILLER: Andy Thrasher Rcuaove