HomeMy WebLinkAboutMechanical EngineeringNOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:54 PM COVER G001 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | MT DRAWN BY | MT WOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS GENERAL G101 CODE PLAN G001 COVER G001 COVER (24x36) G001 COVER (30x42) ARCHITECTURAL A101 CHP - FLOOR PLAN A101 FLOOR PLAN A102 CHP - EQUIPMENT PLATFORM A103 CHP - ROOF PLAN A201 EXTERIOR ELEVATIONS A201 EXTERIOR ELEVATIONS A302 DETAILS A501 FINISH PLAN A601 DOOR AND WINDOW SCHEDULES AND DETAILS A801 INTERIOR ELEVATIONS A901 REFLECTED CEILING PLAN A301 BUILDING SECTIONS & WALL SECTIONS A301 BUILDING SECTIONS A401 STAIR PLANS AND DETAILS A701 ENLARGED PLANS AND DETAILS MECHANICAL M101 SITE PIPING PLAN M201 BOILER PLANT OVERALL MECHANICAL PLAN M202 BOILER PLANT ENLARGED BOILER ROOM PIPING PLAN M203 WOOD FIRED BOILER SYSTEM HEATING WATER FLOW DIAGRAM M301 SCHOOL INTEGRATION PLANS M401 WTP INTEGRATION PLANS M501 FIRE DEPT. INTEGRATION PLANS M601 MECHANICAL DETAILS OWNER CITY OF NENANA 723 A STREET NENANA, AK 907-888-5036 ARCHITECT/ENGINEER CUSHING TERRELL 306 WEST RAILROAD, SUITE 104 MISSOULA, MT 59802 406.728.9522 PROJECT MANAGER: TODD SCHAPER CIVIL / STRUCTURAL ENGINEER ECLIPSE ENGINEERING 113 WEST MAIN, SUITE B MISSOULA, MT 59802 406.721.5733 JESSE FORTUNE, PE This project entails constructing a new wood fired heating plant to heat the main school building, the water treatment facility and the fire department. A new stand-alone building will be constructed to house a wood fired boiler system. The wood chip boiler system will include a chip bin, feed auger, and boiler. Bulk chip storage will be inside the building and chips will be lifted onto the conveyance system which dumps chips into the boiler.Pumps and heat exchangers will be used to transfer heat from the boiler to a district heating loop which will transfer heat into the existing heating systems at the existing buildings. Pre-insulated piping will run from the boiler plant to the school, the water treatment plant, and the fire department . The wood boiler is sized to offset approximately 80% of the current heating energy, and the existing boilers in the buildings will be used for back up and for peak heating times. ELECTRICAL ENGINEER APEX ENGINEERING PO BOX 81822 FAIRBANKS, AK 99708 907.388.0821 JEFF GREEN, PE NORTH REF JULY 23, 2021 WOOD FIRED BOILER PLANT 95% PROGRESS SET Not Enclosed = 0300 EQUIPMENT GARAGE Not Enclosed = 0300 WOOD CHIP STORAGE AREA 209 SF = 1300 PRIMARY CONVEYOR 859 SF = 3300 BOILER ROOM 41 SF = 1100 WC 1340 SF = 9150 FUTURE WORK Redundant Room = 0300 BIOCHAR DEPOSIT 117' 87' 88888 SF = ###### ROOM NAME EXIT PATH SPACE AREA OCCUPANCY TAG: NUMBER OF OCCUPANTS OCCUPANT LOAD FACTOR 1 HOUR FIRE BARRIER -SEAL PERMIETER AND PENETRATIONS PER DETAILS ON THIS SHEET FIRE EXTINGUISHER CABINET AND EXTINGUISHER - SEE SPECIFICATIONSFEC SURFACE MOUNTED FIRE EXTINGUISHER -SEE SPECIFICATIONS FE 60MUL RATED FIRE DOOR AND FRAME WITH RATING AS INDICATED -SEE SHEET A601 NOTE: SEE ELECTRICAL FOR ILLUMINATED EXIT SIGNS. S#SURFACE MOUNTED SIGN -SEE 3/F101 CODE PLAN LEGEND ROOM / AREA NAME ROOM / AREA NUMBER GOVERNING CODES:2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2012 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL FUEL GAS CODE 2018 INTERNATIONAL MECHANICAL CODE OCCUPANCY CLASSIFICATION: 'F1' FIRE SPRINKLER SYSTEM: NOT REQUIRED COMBUSTIBLE STORAGE: SPACES USED FOR STORAGE OF COMBUSTIBLE MATERIALS SHALL BE PROTECTED ON THE STORAGE SIDE AS REQUIRED FOR 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION FROM SECTION 413.2 CONSTRUCTION TYPE: VB BASIC ALLOWABLE HEIGHT AND AREA FROM TABLE 503 ALLOWABLE HEIGHT: 1 STORIES, 40 FEET ALLOWABLE AREA: 8,500 SF TOTAL GROSS BUILDING AREA = 6,925 SF THE AGREGATE AREA OF ALL EQUIPMENT PLATFORMS WITHIN A ROOM SHALL BE NOT GREATER THAN TWO-THIRDS OF THE ARE OF THE ROOM IN WHICH THEY ARE LOCATED. ALLOWABLE SF OF EQUIPMENT PLATFORM: 450 SF ACTUAL SF OF EQUIPMENT PLATFORM: 300 SF REQUIRED SEPARATION OF OCCUPANCIES (HOURS) BETWEEN F1 & B = N, NO SEPARATION REQUIREMENT FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601 FOR TYPE VB, ALL = 0 HOURS FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE FROM TABLE 602 IF FIRE SEPARATION DISTANCE ≥30 FEET, FOR ALL CONSTRUCTION TYPES = 0 HOURS MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION FROM TABLE 705.8 IF FIRE SEPARATION DISTANCE IS 30 FEET OR GREATER FOR UNPROTECTED, NONSPRINKLERED (UP, NS) OPENINGS = NO LIMIT 718.2.2 FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: 1. VERTICALLY AT THE CEILING AND FLOOR LEVELS. 2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET. FOR BUILDINGS IN FLOOD HAZARD AREAS AS ESTABLISHED IN 1612.3, INTERIOR FINISHES, TRIM AND DECORATIVE MATERIALS BELOW THE ELEVATION REQUIRED BY SECTION 1612 SHALL BE FLOOD-DAMAGE-RESISTANT MATERIALS. PER 801.5 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE 803.9 FOR GROUP B, NONSPRINKLERED: EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B CORRIDORS = C ROOMS AND ENCLOSED SPACES = C OCCUPANT LOAD FACTOR FROM TABLE 1004.1.1 BUSINESS AREAS OCCUPANT LOAD FACTOR = 100 SF GROSS FIRST FLOOR AREAS = 31 TOTAL OCCUPANT LOAD = 31 OCCUPANTS MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.1 STAIRWAYS = 31 x 0.3 = 9.3 INCHES REQUIRED, 36" INCHES PROVIDED OTHER EGRESS COMPONENTS =31 x 0.2 = 6.2 INCHES REQUIRED, 36" INCHES PROVIDED ACCESSIBLE MEANS OF EGRESS FROM SECTION 1007 AREA OF REFUGE REQUIRED -AREA OF REFUGE PROVIDED COMMON PATH OF EGRESS TRAVEL FROM SECTION 1014.3 = SHALL NOT EXCEED 75 FEET SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1015.1 FOR B OCCUPANCY, MAXIMUM OCCUPANT LOAD = 49 EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1016.1 FOR F-1 OCCUPANCY, WITHOUT SPRINKLER SYSTEM = 250 FEET CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1018.1 FOR B OCCUPANCY, WITHOUT SPRINKLER SYSTEM, IF OCCUPIED LOAD SERVED BY CORRIDOR IS GREAT THAN 30 = 1 HOUR RATING REQUIRED DEAD END CORRIDORS FROM SECTION 1018.4 = NO MORE THAN 20 FEET STORIES WITH ONE EXIT FROM TABLE 1021.2 SECOND STORY, B OCCUPANCY = 29 OCCUPANTS MAXIMUM PER FLOOR AND 75 FEET TRAVEL DISTANCE EXIT ENCLOSURES PER SECTION 1022 FIRE-RESISTANCE RATING NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR STORIES EXIT ENCLOSURES LEAD DIRECTLY TO THE EXTERIOR OF THE BUILDING CODE REVIEW INFORMATION NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:56 PM CODE PLAN G101 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | Designer DRAWN BY | Author WOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS 1/8" = 1'-0"G101 1 BIOMASS PLANT CODE PLAN NORTH REF W DWD UP UP SCALE: 1" = 1'-0" GENERAL WALL TYPE NOTES: A. SEE INTERIOR ELEVATIONS (SHEET A801) AND FINISH SCHEDULE (SHEET A501) FOR WALL FINISHES. B. PROVIDE BLOCKING AS REQUIRED TO SECURE WALL HUNG COMPONENTS. C. EXTEND ALL COMPONENTS TO UNDERSIDE OF DECK, UNLESS NOTED OTHERWISE. MODIFIERS: 1. 2X4 STUD WALL 2. 2X6 STUD WALL 3. 2x12 STUD WALL 4. ASSEMBLY LEGEND WALL TYPE A STRUCTURAL COLUMN - REFER TO STRUCTURAL 6" 'Z' GIRTS SECURED TO COLUMNS AT CONNECTION POINT. INSULATED METAL PANELS (PROVIDED BY OWNER) PROVIDE 6" FIBER GLASS BATT INSULATION MIN. 6 MIL VAPOR BARRIER INTERIOR SIDEWALL TYPE B 5/8" GYP. 5/8" OSB SHEATHING PROVIDE 9" FIBER GLASS BATT INSULATION MIN. 6 MIL VAPOR BARRIER INTERIOR SIDECONTINUOUS AIR AND MOISTURE BARRIER (TYVEK) OR SIMILAR. HORIZ. LAP SIDING TO BE SELECTED BY OWNER. WALL TYPE C 5/8" GYP. PROVIDE SOUND BATT INSULATION 2X STUDS (DEPENDENT ON LOCATION) 5/8" GYP. 2X10 STUDS INSULATED METAL PANELS (PROVIDED BY OWNER) PURLINS -SEE STRUCTURAL FOR DETAILS. STRUCTURAL STEEL BEAM -SEE STRUCTURAL FOR DETAILS. ROOF TYPE A WALL TYPE D 8" REINFORCED CONCRETE PROVIDE FIREBLOCKING PER IBC 718.2.2. ASSEMBLY TYPE (SEE ASSEMBLIES SHEET) ASSEMBLY MODIFIER, PER TYPE ROOM NAME AND NUMBER WINDOW TYPE (SEE A600s) KEYNOTE DRAWING NUMBER SHEET WHERE DRAWN DOOR NUMBER (SEE SHEET A601) DIMENSION TO FACE OF FRAMING DIMENSION TO GRID LINE101-11 A101 SIM ______________ X XX NAME 101 X X PLAN LEGEND DIRECTION OF VIEW, IF APPLICABLE DIMENSION TO CENTER LINE CL FUTURE WORK -NOT IN CONTRACT A201 1 A201 3 1 2 A B C D E 2 A301 ______________ 4 A301 ______________64'-0"16'-0"16'-0"16'-0"16'-0"100'-0"22'-9 1/2"38'-0"30'-0"13'-6"16'-0"8'-8"6'-1"34'-0"13'-0"8'-9" 10'-0" 9'-0"20'-0"10'-6" 35'-2"12'-0"105-3 104-3105-1105-2101-1101-2106-2106-1104-1106-4 104-2107-1 106-5106-61 2 2 BIOCHAR DEPOSIT 106A BOILER ROOM 106 PRIMARY CONVEYOR 108 EQUIPMENT GARAGE 105 WOOD CHIP STORAGE AREA 104 VESTIBULE 101 WC 1076'-0"12'-0"21'-8"3'-2" ______________ A401 1 A A B B A B B B A C D C 16'-0"1'-8"8'-3"4'-7"33'-6"C C 10 101010 10 3 C C 11 11 11 5'-3"20'-0"38'-9"30'-9"1'-0"______________ A401 2 22'-6"A. DIMS TO EQUIPMENT TAKEN FROM FINISH FACE OF WALL INDINCATION CLEAR FLOOR SPACE. GENERAL NOTES 1. 4" DIA. STEEL PIPE FILLED W/ CONC. 48" H. PLACE 36" BELOW GRADE. SET BOLLARD IN CONC. 10" IN DIA. W/ 6" BELOW BOTTOM OF BOLLARD. 2. PRIMARY CONVEYOR. PROVIDED BY OWNER. 3. HALF HEIGHT WALL. CAP W/ 12 GA. SHEET METAL AND SLOPE TO PRIMARY CONVEYOR. 4. SECONDARY CONVEYOR. PROVIDED BY OWNER. 5. BOILER -SEE MECHANICAL DRAWINGS. 6. SCREW CONVEYOR. PROVIDED BY OWNER. 7. CONCRETE LANDING @ DOOR. 8. HOUSE KEEPING PAD. SEE STRUCTURAL DRAWINGS. 9. DOG HOUSE TO SHELTER PIPING -SEE DETAIL. 10. FLOOR DRAIN -SEE PLUMBING DRAWINGS. 11. ASSEMBLED METAL STAIR W/ SERRATED METAL GRATE TREADS. 12. PROVIDE 42" GUARDRAIL. 13. PROVIDE TWO BAR SNOW RAIL -SECURE TO ROOF PER MFR'S REQUIREMENTS. 14. INSULATED OH SECTIONAL DOORS. #KEYNOTES NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:37 PM CHP - FLOOR PLAN A101 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | MT DRAWN BY | MT WOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS 1/8" = 1'-0"A101 1 BIOMASS PLANT FIRST FLOOR PLAN NORTH REF DOOR, FRAME AND... DOOR NUMBER ROOM NUMBER DOOR SIZE W H 23 3'-0" 6'-8" 24 3'-0" 6'-8" 25 3'-0" 6'-8" 26 3'-0" 6'-8" 42 6'-0" 6'-8" 101-1 6'-0" 6'-8" 101-2 109 6'-0" 6'-8" 104-1 16'-0" 16'-0" 104-2 3'-0" 6'-8" 104-3 3'-0" 6'-8" 105-1 12'-0" 12'-0" 105-2 12'-0" 12'-0" 105-3 3'-0" 6'-8" 106-1 3'-0" 6'-8" 106-2 6'-0" 6'-0" 106-4 6'-0" 6'-8" 106-5 106 3'-0" 6'-8" 106-6 8'-0" 10'-0" 107-1 106 2'-6" 6'-8" nic109-1 109 2'-6" 6'-8" nic 103-1 109 2'-8" 6'-8" nic 110 109 2'-6" 6'-8" nic 110-1 109 3'-0" 6'-8" nic 113-1 109 2'-8" 6'-8" nic 114-1 109 2'-6" 6'-8" nic - 111 109 2'-8" 6'-8" A201 3 1 2 C D E 2 A301 ______________ 4 A301 ______________20'-0"1'-6"11 7'-6"26'-0" 12 SCALE: 1" = 1'-0" GENERAL WALL TYPE NOTES: A. SEE INTERIOR ELEVATIONS (SHEET A801) AND FINISH SCHEDULE (SHEET A501) FOR WALL FINISHES. B. PROVIDE BLOCKING AS REQUIRED TO SECURE WALL HUNG COMPONENTS. C. EXTEND ALL COMPONENTS TO UNDERSIDE OF DECK, UNLESS NOTED OTHERWISE. MODIFIERS: 1. 2X4 STUD WALL 2. 2X6 STUD WALL 3. 2x12 STUD WALL 4. ASSEMBLY LEGEND WALL TYPE A STRUCTURAL COLUMN - REFER TO STRUCTURAL 6" 'Z' GIRTS SECURED TO COLUMNS AT CONNECTION POINT. INSULATED METAL PANELS (PROVIDED BY OWNER) PROVIDE 6" FIBER GLASS BATT INSULATION MIN. 6 MIL VAPOR BARRIER INTERIOR SIDEWALL TYPE B 5/8" GYP. 5/8" OSB SHEATHING PROVIDE 9" FIBER GLASS BATT INSULATION MIN. 6 MIL VAPOR BARRIER INTERIOR SIDECONTINUOUS AIR AND MOISTURE BARRIER (TYVEK) OR SIMILAR. HORIZ. LAP SIDING TO BE SELECTED BY OWNER. WALL TYPE C 5/8" GYP. PROVIDE SOUND BATT INSULATION 2X STUDS (DEPENDENT ON LOCATION) 5/8" GYP. 2X10 STUDS INSULATED METAL PANELS (PROVIDED BY OWNER) PURLINS -SEE STRUCTURAL FOR DETAILS. STRUCTURAL STEEL BEAM -SEE STRUCTURAL FOR DETAILS. ROOF TYPE A WALL TYPE D 8" REINFORCED CONCRETE PROVIDE FIREBLOCKING PER IBC 718.2.2. ASSEMBLY TYPE (SEE ASSEMBLIES SHEET) ASSEMBLY MODIFIER, PER TYPE ROOM NAME AND NUMBER WINDOW TYPE (SEE A600s) KEYNOTE DRAWING NUMBER SHEET WHERE DRAWN DOOR NUMBER (SEE SHEET A601) DIMENSION TO FACE OF FRAMING DIMENSION TO GRID LINE101-11 A101 SIM ______________ X XX NAME 101 X X PLAN LEGEND DIRECTION OF VIEW, IF APPLICABLE DIMENSION TO CENTER LINE CL FUTURE WORK -NOT IN CONTRACT A. DIMS TO EQUIPMENT TAKEN FROM FINISH FACE OF WALL INDINCATION CLEAR FLOOR SPACE. GENERAL NOTES 1. 4" DIA. STEEL PIPE FILLED W/ CONC. 48" H. PLACE 36" BELOW GRADE. SET BOLLARD IN CONC. 10" IN DIA. W/ 6" BELOW BOTTOM OF BOLLARD. 2. PRIMARY CONVEYOR. PROVIDED BY OWNER. 3. HALF HEIGHT WALL. CAP W/ 12 GA. SHEET METAL AND SLOPE TO PRIMARY CONVEYOR. 4. SECONDARY CONVEYOR. PROVIDED BY OWNER. 5. BOILER -SEE MECHANICAL DRAWINGS. 6. SCREW CONVEYOR. PROVIDED BY OWNER. 7. CONCRETE LANDING @ DOOR. 8. HOUSE KEEPING PAD. SEE STRUCTURAL DRAWINGS. 9. DOG HOUSE TO SHELTER PIPING -SEE DETAIL. 10. FLOOR DRAIN -SEE PLUMBING DRAWINGS. 11. ASSEMBLED METAL STAIR W/ SERRATED METAL GRATE TREADS. 12. PROVIDE 42" GUARDRAIL. 13. PROVIDE TWO BAR SNOW RAIL -SECURE TO ROOF PER MFR'S REQUIREMENTS. 14. INSULATED OH SECTIONAL DOORS. #KEYNOTES NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:38 PM CHP - EQUIPMENT PLATFORM A102 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | Designer DRAWN BY | Author WOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS 1/8" = 1'-0"A102 1 EQUIPMENT PLATFORM & MEZZANINE PLAN NORTH REF MA201 1 A2012 A201 A201 3 4 1 2 A B C D E 2 A301 ______________ 4 A301 ______________ 6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"6" / 1'-0"64'-0"23'-0"22'-11" 100'-0"64'-0"100'-0" ASSEMBLY TYPE (SEE ASSEMBLIES SHEET) ASSEMBLY MODIFIER, PER TYPE ROOM NAME AND NUMBER WINDOW TYPE (SEE A600s) KEYNOTE DRAWING NUMBER SHEET WHERE DRAWN DOOR NUMBER (SEE SHEET A601) DIMENSION TO FACE OF FRAMING DIMENSION TO GRID LINE101-11 A101 SIM ______________ X XX NAME 101 X X PLAN LEGEND DIRECTION OF VIEW, IF APPLICABLE DIMENSION TO CENTER LINE CL FUTURE WORK -NOT IN CONTRACT A. DIMS TO EQUIPMENT TAKEN FROM FINISH FACE OF WALL INDINCATION CLEAR FLOOR SPACE. GENERAL NOTES NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:40 PM CHP - ROOF PLAN A103 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | Designer DRAWN BY | Author WOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS 1/8" = 1'-0"A103 1 ROOF PLAN NORTH REF #KEYNOTES T.O. FF 100'-0" 1 2 4 A301 ______________ T.O. EQUIPMENT PLATFORM FF 108'-10 3/4" T.O. EAVE STRUT 116'-5 1/4" 103'-0" 101'-0" 111 13 1313 13 T.O. MEZZ. FF 108'-10" 145'-0" 14 14 T.O. FF 100'-0" A B C D E 2 A301 ______________ T.O. EQUIPMENT PLATFORM FF 108'-10 3/4" T.O. EAVE STRUT 116'-5 1/4" 13 13 103'-0" 11 T.O. MEZZ. FF 108'-10" T.O. FF 100'-0" 12 4 A301 ______________ T.O. EQUIPMENT PLATFORM FF 108'-10 3/4" T.O. EAVE STRUT 116'-5 1/4" 13 13 11 13 T.O. MEZZ. FF 108'-10" 14 T.O. FF 100'-0" ABCDE 2 A301 ______________ T.O. EQUIPMENT PLATFORM FF 108'-10 3/4" T.O. EAVE STRUT 116'-5 1/4" 13 13 103'-0"1 INSULATED METAL PANELS ( PROVIDED BY OWNER) MATERIAL 3 WOOD LAP SIDING MATERIALS LEGEND A. DIMS TO EQUIPMENT TAKEN FROM FINISH FACE OF WALL INDINCATION CLEAR FLOOR SPACE. GENERAL NOTES 1 3'-0"6'-8"3'-0"3'-0"6'-8"6'-0"6'-0"3'-0"4'-0"1'-0"6'-0"5'-0"3'-0" 1. 4" DIA. STEEL PIPE FILLED W/ CONC. 48" H. PLACE 36" BELOW GRADE. SET BOLLARD IN CONC. 10" IN DIA. W/ 6" BELOW BOTTOM OF BOLLARD. 2. PRIMARY CONVEYOR. PROVIDED BY OWNER. 3. HALF HEIGHT WALL. CAP W/ 12 GA. SHEET METAL AND SLOPE TO PRIMARY CONVEYOR. 4. SECONDARY CONVEYOR. PROVIDED BY OWNER. 5. BOILER -SEE MECHANICAL DRAWINGS. 6. SCREW CONVEYOR. PROVIDED BY OWNER. 7. CONCRETE LANDING @ DOOR. 8. HOUSE KEEPING PAD. SEE STRUCTURAL DRAWINGS. 9. DOG HOUSE TO SHELTER PIPING -SEE DETAIL. 10. FLOOR DRAIN -SEE PLUMBING DRAWINGS. 11. ASSEMBLED METAL STAIR W/ SERRATED METAL GRATE TREADS. 12. PROVIDE 42" GUARDRAIL. 13. PROVIDE TWO BAR SNOW RAIL -SECURE TO ROOF PER MFR'S REQUIREMENTS. 14. INSULATED OH SECTIONAL DOORS. #KEYNOTES NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:48 PM EXTERIOR ELEVATIONS A201 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | THOME DRAWN BY | THOME WOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS 1/8" = 1'-0"A201 1 SOUTH 1/8" = 1'-0"A201 2 EAST 1/8" = 1'-0"A201 3 NORTH 1/8" = 1'-0"A201 4 WEST 1/4" = 1'-0" DOOR & WINDOW ELEVATIONS T.O. FF 100'-0" EQUIPMENT PLATFORM 114'-0" 12 4 A301 ______________ ______________ A301 1 T.O. EAVE STRUT 116'-5 1/4" T.O. MEZZ. FF 108'-10" T.O. FF 100'-0" EQUIPMENT PLATFORM 114'-0" A B C D E 2 A301 ______________ EQUIPMENT PIT 02 97'-0" FIRST FLOOR 100'-0" SECOND FLOOR 114'-0" T.O. EAVE STRUT 116'-5 1/4" 1. 4" DIA. STEEL PIPE FILLED W/ CONC. 48" H. PLACE 36" BELOW GRADE. SET BOLLARD IN CONC. 10" IN DIA. W/ 6" BELOW BOTTOM OF BOLLARD. 2. PRIMARY CONVEYOR. PROVIDED BY OWNER. 3. HALF HEIGHT WALL. CAP W/ 12 GA. SHEET METAL AND SLOPE TO PRIMARY CONVEYOR. 4. SECONDARY CONVEYOR. PROVIDED BY OWNER. 5. BOILER -SEE MECHANICAL DRAWINGS. 6. SCREW CONVEYOR. PROVIDED BY OWNER. 7. CONCRETE LANDING @ DOOR. 8. HOUSE KEEPING PAD. SEE STRUCTURAL DRAWINGS. 9. DOG HOUSE TO SHELTER PIPING -SEE DETAIL. 10. FLOOR DRAIN -SEE PLUMBING DRAWINGS. 11. ASSEMBLED METAL STAIR W/ SERRATED METAL GRATE TREADS. 12. PROVIDE 42" GUARDRAIL. 13. PROVIDE TWO BAR SNOW RAIL -SECURE TO ROOF PER MFR'S REQUIREMENTS. 14. INSULATED OH SECTIONAL DOORS. #KEYNOTES T.O. FF 100'-0" 2 T.O. EQUIPMENT PLATFORM FF 108'-10 3/4" EXISTING CONCRETE FOUNDATION / STEMWALL INSULATED METAL PANEL - SECURE TO GIRTS (PROVIDED) ENGINEERED METAL COLUMNS. BATT INSULATION GIRTS SECURED TO OUTSIDE FACE OF ENGINEERED METAL COLUMN. SHED ROOF T.O.P. 108'-4 1/2" T.O. EAVE STRUT 116'-5 1/4" T.O. MEZZ. FF 108'-10"NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:50 PM BUILDING SECTIONS & WALL SECTIONS A301 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | LAST NAME DRAWN BY | LAST NAMEWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS 1/8" = 1'-0"A301 2 Section 2 1/8" = 1'-0"A301 4 Section 4 1/2" = 1'-0"A301 1 TYP. EXTERIOR WALL SECTION C D 1'-0"1"5'-0 19/32" 4 A401 ______________ E 3 A401 ______________ T.O. FF 100'-0" EQUIPMENT PLATFORM 114'-0" SHED ROOF T.O.P. 108'-4 1/2" T.O. FF 100'-0" EQUIPMENT PLATFORM 114'-0" C D FIRST FLOOR 100'-0" SECOND FLOOR 114'-0" SHED ROOF T.O.P. 108'-4 1/2" T.O. EAVE STRUT 116'-5 1/4"NOT FOR CONSTRUCTION - PRELIMINARY DESIGN REVISIONS 7/23/2021 2:00:52 PM STAIR PLANS AND DETAILS A401 07.23.2021 © 2021 | ALL RIGHTS RESERVED 95% PROGRESS SET DESIGNED BY | LAST NAME DRAWN BY | LAST NAMEWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\Revit PROJECT# | NENANA_BIOMASS #KEYNOTES 1/4" = 1'-0"A401 1 WEST STAIR PLAN 1/4" = 1'-0"A401 2 MEZZANINE STAIR PLAN 1/4" = 1'-0"A401 3 MEZZANINE STAIR SECTION 1/4" = 1'-0"A401 4 WEST STAIR SECTION DRAINHEATING WATER SUPPLYHEATING WATER RETURNFUEL OIL SUPPLYFUEL OIL RETURNFUEL OIL VENTGATE VALVEBALL VALVEBUTTERFLY VALVESWING CHECK VALVESTRAINERFLEX CONNECTORHOSE END DRAIN VALVEPRESSURE REDUCING VALVESAFETY RELIEF VALVEUNIONMOTORIZED T.C. VALVE / 2-WAYMOTORIZED T.C. VALVE / 3-WAYTEE UPTEE DOWNELBOW UPELBOW DOWNPIPE SIZE CHANGEMANUAL FLOW BALANCING VALVE (CIRCUIT SETTER)PRESSURE / TEMP. TEST PLUGDIAL THERMOMETERABOVE FINISHED FLOORAMERICAN NATIONAL STANDARDS INSTITUTEAMPERE (AMP, AMPS)APPROXIMATEBRAKE HORSEPOWER, BOILER HORSEPOWERBRITISH THERMAL UNITBTU PER HOUR (THOUSAND)COMMONCIRCULATIONDIAMETERDIAMETER, INSIDEDIAMETER, OUTERDRY-BULB TEMPERATUREDOWNDOMESTICENTERING AIR TEMPERATUREELECTRICAL CONTRACTOREXPANSIONENTERING WATER TEMPERATUREFAHRENHEITFROM ABOVEFLOOR DRAINFEET PER MINUTEFEET PER SECONDFOOT OR FEETFREQUENCYGAGE OR GAUGEGALLONSGENERAL CONTRACTORGALLONS PER HOURGALLONS PER MINUTEGALLONS PER DAYHEADHEIGHTHORSEPOWERKILOWATTKILOWATT HOURLEAVING WATER TEMPERATURELINEAR FEETMAXIMUMMECHANICAL CONTRACTORMINIMUMNORMALLY OPENNORMALLY CLOSEDNOT APPLICABLENOT IN CONTRACTNOT TO SCALENUMBERPERCENTPHASE (ELECTRICAL)POUNDSPOUNDS PER SQUARE INCHPSI ABSOLUTEPRESSURE DROPPSI GAUGERUN OUTREVOLUTIONS PER MINUTESENSIBLE HEATSPECIFICATIONSPECIFIC VOLUMESTANDARDSTATIC PRESSURESUCTIONTEMPERATURETEMPERATURE DIFFERENCETHERMOSTATTEMPERATURE CONTROLUNIFORM ENERGY FACTORVELOCITYVOLTVOLUMEVARIABLE FREQUENCY DRIVEWATER PRESSURE DROPWITHTHERMOSTAT/TEMPERATURE SENSORCONNECT NEW WORK TO EXISTINGPRESSURE GAUGE W/ SNUBBERCOMMONEXISTINGDHWSHWRFOSFORFOVTTC(E)PSYMBOLDESCRIPTIONSYMBOLDESCRIPTIONMMMMMMMMMMMMMMMMAFFANSIAMPAPPROXBHPBTUMBHCCIRC.DIA IDODDBTDNDOM.EATECEXPEWTFFAFDFPMFPSFTHZGAGALG.C.GPHGPMGPDHDHGTHPKWKWHLWTLFMAXMCMINNONCN/ANICNTSNO%PHLBSPSIPSIAPDPSIGR/ORPMSHSPECSP VOLSTDSPSUCTTEMPTDT STATTCUEFVELVVOLVFDWPDW/MECHANICAL LEGENDHVAC ABBREVIATIONSDOMESTIC HOT WATER CIRC.HWCDOMESTIC HOT WATERHWDOMESTIC COLD WATERCWEXPANSION TANKXTNOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 3:17:14 PMMECHANICALSCHEDULES &LEGENDSM00107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASSM101 SITE PIPING PLANM201 BOILER PLANT OVERALL MECHANICAL PLANM202 BOILER PLANT ENLARGED BOILER ROOM PIPING PLANM203 WOOD FIRED BOILER SYSTEM HEATING WATER FLOW DIAGRAMM301 SCHOOL INTEGRATION PLANSM401 WTP INTEGRATION PLANSM501 FIRE DEPT. INTEGRATION PLANSM601 MECHANICAL DETAILSMECHANICAL SHEET INDEX3 - PROVIDED WITH HORIZONTAL CONVEYOR AND ANGLED LIFT CONVEYOR.2 - PROVIDE WITH FLUE INDUCTION FAN, ASH AUGER, BIOCHAR AUGER, METERING BIN, CONTROLS, AND ALL OTHER COMPONENTS REQUIRED FOR A COMPLETE AND FUNCTIONAL SYSTEM1 - OWNER PROVIDED, CONTRACTOR INSTALLEDNOTES:B-1BIOMASS ENERGYTECHNIQUESBET 24-S 1,400 350 16" 230/1/60 54 x 138 x 144 NOTES 1,2,3PLANCODEMFGR MODELBURN RATE(MBH)BOILER WATERCONTENT (GAL)FLUESIZEPOWER(V/PH/HZ)DIMENSIONS W x H x L(IN x IN x IN)REMARKSBIOMASS BOILER SCHEDULE1 - PROVIDE ASME RATED TANK.NOTES:XT-1 TACO CA-1000 BLADDER WATER 264 264 36x80 18 40 50 200 2800NOTE 1TANKVOL.(GAL)ACCEPTANCEVOL.(GAL)DIA. /HEIGHT(INxIN)PLANCODEMFGR MODEL TYPEWORKINGFLUIDPHYSICALPRECHARGEPRESSURE(PSIG)MAXIMUMSYSTEMPRESSURE(PSIG)MIN. TEMP(°F)MAX. TEMP(°F)EST. SYSTEMVOLUME(GAL)REMARKSEXPANSION TANK SCHEDULE4. UTILIZE A LASER ALIGNMENT TOOL TO INSTALL PUMP AND COMPONENTS TO ENSURE PROPER PUMP...3. PROVIDE PREMIUM EFFICIENT MOTOR COMPATIBLE WITH VFD.2. PROVIDE AND INSTALL SHAFT GROUNDING RING MOTOR BEARING PROTECTION, AEGIS MODEL SGR OR...1. PROVIDE WITH SEALS COMPATIBLE WITH WORKING FLUID.5. PROVIDE SUCTION DIFFUSER ON PUMP INLET MATCHED TO SYSTEM PIPE SIZE AND PUMP SUCTION SIZE. PROVIDEFROM SAME MANUFACTURER AS PUMP.NOTES:P-FD TACO IL0012 INLINE FD HX 7.5 10 WATER - 0.5 1760 115/1/60NOTE 1P-WTP TACO 1611 INLINE WTP HX 50 15 50% P. GLY. - 0.5 1760 115/1/60 NOTE 1P-SCH TACO 1635 INLINE SCHOOL HX 60 15 WATER - 0.5 1760 115/1/60 NOTE 1BP-2 GRUNDFOS ALPHA 15-55 INLINE OIL BOILER 7 5 WATER - 45 WATTS 1760 115/1/60 NOTE 1BP-1 TACO 1635 INLINE WOOD BOILER 110 20 WATER - 0.33 1760 120/1/60 NOTE 1P-3 TACO 1611 INLINE BOILER PLANT HTG 15 20 WATER - 1 1750 NOTE 1P-2 TACO SFI2009 BASE MOUNTED DISTRICT HEATING 120 60 WATER 8.8" 5 1760 460/3/60 NOTES 1, 2, 3, 4, 5P-1 TACO SFI2009 BASE MOUNTED DISTRICT HEATING 120 60 WATER 8.8" 5 1760 460/3/60 NOTES 1, 2, 3, 4, 5FLOW(GPM)HEAD(FT)WORKINGFLUIDMINHPRPMPOWER(V/PH/HZ)PLANCODEMFGR MODEL TYPE SERVICEFLUIDMOTOR IMPELLAR DIAMOTORREMARKSPUMP SCHEDULEHX-FD KELVION FG10X20-30 92 WATER 7.5 185 160 0.3 WATER 7.5 155 180 0.3 0.0001HX-WTP KELVION FG10X20-130 610 WATER 50 185 160 0.850% PROPYLENEGLYCOL67.8 155 175 1.6 0.0001 -HX-SCH KELVION FG10X20-180 732 WATER 60 185 160 0.7 WATER 60 155 180 0.7 0.0001 -FLUIDFLOW(GPM)EWT(°F)LWT(°F)WPD(PSI)FLUIDFLOW(GPM)EWT(°F)LWT(°F)WPD(PSI)PLANCODEMFGR MODEL NO. PLATESCAPACITY(MBH)HOT SIDE DATACOLD SIDE DATAFOULINGFACTORREMARKSBRAZED PLATE HEAT EXCHANGER SCHEDULEADS-1 TACO 4903AD-125 3" 120 WATER 5 85.0 ASME RATEDFLOW RATE(GPM)WORKING FLUIDHEADLOSS (FT)PLANCODEMFGR MODEL SIZEFLUIDWEIGHT(LB)REMARKSAIR / DIRT SEPARATOR SCHEDULE1) 50% PROPYLENE GLYCOL. 2) RUBBER-IN-SHEAR ISOLATORS. 3) NON-FUSED DISCONNECTNOTES:UH-1 VULCAN HV-125A 13,651 2.5 460 1350 25 120/1/60 NOTES 1, 2, 3PLANCODEMFGR MODEL BTU/H GPM CFM RPM HP (WATTS)POWER(V/PH/HZ)REMARKSUNIT HEATER SCHEDULE2 - PROVIDE BIRDSCREEN.1 - PROVIDE BAKED ENAMEL FINISH, COLOR BY ARCHITECTURAL.NOTES:L-5 RUSKIN ELF6375 ERV EXHAUST FLANGE 30 X 24 - ALUMINUM NOTES 1, 2L-4 RUSKIN ELF6375 HRV INTAKE FLANGE 30 X 24 - ALUMINUM NOTES 1, 2L-3 RUSKIN ELF6375 MAU INTAKE FLANGE 30 X 24 - ALUMINUM NOTES 1, 2L-2 RUSKIN ELF6375 CHIP VENT. FLANGE 30 X 24 - ALUMINUM NOTES 1, 2L-1 RUSKIN ELF6375 COMB. AIR FLANGE 72 X 60 - ALUMINUM NOTES 1, 2PLANCODEMFGR MODEL NO. SERVICE FRAME TYPEWIDTH x HEIGHT(IN x IN)FREE AREA(SQ. FT.)MAX APD(IN W.C.)MATERIAL REMARKSWALL LOUVER SCHEDULENOTES:EF-1 COOK APD WALL CHIP VENT. DIRECT 1500 0.3 0.5 120/1/60 -PLANCODEMFGR MODEL TYPE SERVICE DRIVE CFM RPMESP(IN WC)MOTORHP (W)POWER(V/PH/HZ)REMARKSEXHAUST FAN SCHEDULE2 - AT MINIMUM PROVIDE 5 TAPS FOR HEATING WATER, 1 TAP ON TOP FOR FILL AND VENT, AND 1 TAP IN MIDDLE OF TANK VERTICALLY.1 - SEE M203 FOR TAP LOCATION INFORMATION.NOTES:TST-1 LOCHINVAR CUSTOM WATER 52 128 1,000 4 INSULATE TANK. NOTES 1, 2PLANCODEMFGR MODEL NO. FLUIDDIAMETER(IN)HEIGHT (IN)TANK VOL.(GAL)CONNECTIONSIZES (IN)REMARKSTHERMAL STORAGE TANK SCHEDULE1 - HEATING FLUID IS 100% WATER.NOTES:3 FUTURE WASHATERIA 1237 14.3 9.2 1.5 1.4 12 275 5 1/2" 1" NOTE 12 WOOD CHIP STORAGE 2467 57.3 21.7 6.0 7.6 12 300 9 1/2" 1" NOTE 11 EQUIPMENT GARAGE 1199 57.4 39.3 5.5 14.4 12 300 5 1/2" 1" NOTE 1ZONE # AREA SERVEDAREA(SF)PANEL LOAD(MBH)HEATINGINTENSITY(BTUH/SF)FLOWRATE(GPM)WPD(FT W.G.)TUBESPACING(IN)CIRCUITLENGTH(FT)#CIRCUITSTUBEØMANIFOLDØSUPPLYTEMP (°F)IN-FLOOR RADIANT HEATING SCHEDULEB-2 TOYOTOMI OM-128 148 129 5 120 / 1 / 60 NO. 1 FUEL OILPLANCODEMFGR MODEL INPUT (MBH) OUTPUT (MBH)VENT DIA.(INCHES)POWER(V/PH/HZ)REMARKSFUEL OIL BOILER SCHEDULE WDWDNENANA SCHOOLWATER TREATMENT PLANTNENANA FIRE DEPARTMENTBOILER PLANTFUTURE GREENHOUSE3" HWS/R3" HWS/R2" HWS/R45 FT70 FT270 FT225 FT220 FT50 FT25 FTBOILER ROOMBOILER ROOMBOILER ROOM1 1/2" HWS/RWEST LOOP 1 1/2"HORIZONTAL DISTANCE50 FTRISER AT WTP15 FTRISER AT FIRE DEPT.15 FT80 FTWEST LOOP 3"HORIZONTAL DISTANCE540 FTRISER AT BOILER PLANT 15 FTRISER AT WTP 15 FT570 FTSOUTH LOOP 2"HORIZONTAL DISTANCE70 FTRISER AT BOILER PLANT15 FT85 FTEAST LOOPHORIZONTAL DISTANCE385 FTRISER AT BOILER PLANT 15 FTRISER AT SCHOOL 15 FT415 FTNOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 3:17:57 PMSITE PIPING PLANM10107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1" = 50'-0"M1011SITE PIPING PLAN WDWDMEDCBA12______________M2021HWS/R BELOW GRADE TO/FROM BUILDINGS, SEE SITE PIPING PLAN FOR CONTINUATION4"HWRHWSIN FLOOR RADIANT HEATING ZONE 1111L-2EF-1______________M2012HWSHWR3"3"EQUIPMENT PLATFORMIN FLOOR RADIANT HEATING ZONE 2IN FLOOR RADIANT HEATING ZONE 3EQUIPMENTGARAGE105WOOD CHIPSTORAGE AREA104BIOCHAR DEPOSIT106AVESTIBULE101??PRIMARYCONVEYOR108WC107FUTUREPIPING241 1/2"1 1/2"3/4"3/4"1 1/2"1 1/2"$GENERAL NOTESA. DO NOT RUN ANY PIPING OVER ELECTRICAL PANELS FROM PANEL TO STRUCTURE ABOVE AND FROM ACCESS SPACE TO 80" ABOVE FLOOR.B. TEMPERATURE SENSOR LOCATIONS SHALL BE REVIEWED WITH ARCHITECTURAL FIELD REPRESENTATIVE PRIOR TO INSTALLATION. INSTALL THERMOSTAT 48" ABOVE FINISHED FLOOR AS REQUIRED FOR PROPER EQUIPMENT INSTALLATION.C. CEILING SPACE THROUGHOUT THIS BUILDING IS VERY CONGESTED. COORDINATE ROUTING OF PIPING WITH ALL TRADES PRIOR TO INSTALLATION.#SHEET NOTES1. IN FLOOR RADIANT HEAT MANIFOLD, SEE A/M201 FOR RADIANT FLOOR MANIFOLD PIPING DETAIL.2. MOUNT SWITCH FOR EF-1/L-2 DAMPER ON WALL. PROVIDE LABEL "CHIP ROOM VENTILATION ON/OFF"3. INFILL BACK OF LOUVER WITH 4" THICK RIGID INSULATION AND SEAL AIR TIGHT.4. 30X30 MOTORIZED DAMPER, NORMALLY CLOSED, INTERLOCKED WITH EF-1.ED2EQUIPMENTPLATFORM202FUTURE MAUFUTURE ERVL-3L-4L-5FUTURE DOMESTIC WATER HEATERS3"3"FUTURE PIPINGCNCNOAAAAAAAAAAAAAAAA3-WAY MODULATING CONTROL VALVEMANIFOLD IN WALL ACCESS BOX, SIZE PER SCHEDULEUNDER SLAB SNOWMELT OR HEATING WATER RUNOUTS, SIZE PER PLANSAUTOFLOWSTRAINERUNION (TYP.)REDUCER AS RQD (TYP)BALL VALVE (TYP.)PETE'S PLUG (TYP.)MANUAL AIR VENT @ HIGHPOINT, TYP.SUPPORT MANIFOLD TO WALL W/ UNISTRUT (TYP.)FULL PORT BALL VALVE (TYP.)PIPE W/ REVERSE RETURNHOSE END GATE VALVE AS DRAINBARBED FITTING W/ MANUFACTURER CLAMP RING FOR TRANSITION TO PEX (TYP)UNISTRUT GUIDE SUPPORTING PEXMNOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 3:19:03 PMBOILER PLANTOVERALLMECHANICAL PLANM20107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/8" = 1'-0"M2011OVERALL MECHANICAL PLAN - BOILER PLANT1/4" = 1'-0"M2012BOILER PLANT ENLARGED EQUIPMENT PLATFORM PLANNOT TO SCALEM201ARADIANT FLOOR MANIFOLD PIPING DIAGRAMNORTH REF1680SCALE IN FEETSCALE: 1/8" = 1'-0"1680SCALE IN FEETSCALE: 1/8" = 1'-0"NORTH REF333 ED11M601______________B-2B-1HWSHWRHWSHWRL-1ELECTRICAL EQUIPMENTBOILERROOM106PRIMARYCONVEYOR108WC107TST-1BP-2ADS-1BP-1P-1P-21 1/2"1 1/2"]]22FUEL OIL TANKFUTURE PIPINGXT-1P-331500 GALLON FUEL OIL TANK8'-6" MAX.2" FILL PIPELEVEL GAUGEPRIMARY AND EMERGENCY VENTSTANK SHALL BE OF DOUBLE WALL - TYPE 1 CONSTRUCTION,UL 142 LISTED.FLANGED LEGSGROUND SUPPORT RAILS6'-0" MIN.SHUT-OFF VALVE3/4" COPPER LINESEAL WALL PENETRATION WATER TIGHTSHUT-OFF VALVESIZE PER BURNER MANUFACTURER'S RECOMMENDATIONFUEL FILTERBURNERTANK INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE IFGC, CHAPTERS 27 & 34GENERAL NOTESA. DO NOT RUN ANY PIPING OVER ELECTRICAL PANELS FROM PANEL TO STRUCTURE ABOVE AND FROM ACCESS SPACE TO 80" ABOVE FLOOR.B. TEMPERATURE SENSOR LOCATIONS SHALL BE REVIEWED WITH ARCHITECTURAL FIELD REPRESENTATIVE PRIOR TO INSTALLATION. INSTALL THERMOSTAT 48" ABOVE FINISHED FLOOR AS REQUIRED FOR PROPER EQUIPMENT INSTALLATION.C. CEILING SPACE THROUGHOUT THIS BUILDING IS VERY CONGESTED. COORDINATE ROUTING OF PIPING WITH ALL TRADES PRIOR TO INSTALLATION.NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 4:12:38 PMBOILER PLANTENLARGED BOILERROOM PIPING PLANM20207.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/4" = 1'-0"M2021ENLARGED BOILER ROOM PIPING PLAN - BOILER PLANTNORTH REFNOT TO SCALEM202AFUEL OIL TANK DETAILSHEET NOTES1. SEE M203 FOR FLOW DIAGRAM OF THIS AREA2. CAP HWS AND HWR PIPE BRANCHES SERVING FUTURE CAFETERIA JUST DOWNSTREAM OF TEE.3. 16" DIAMETER ALL FUEL STACK, TYPE UL 103 HT. EXTEND THROUGH ROOF, 15'-0" ABOVE ROOF LINE. INSTALL GUY WIRE TO STABILIZE STACK. TTTTTTTTTTTTTFMTTBIOMASS BOILERB-1PVFDPVFDTTTTPTTTTPFUTURE GREENHOUSETTPCXCXCXCXTO/FROMB-1B-1AHTX-SCHHTX-FDHTX-WTPWATER TREATMENT PLANTFIRE DEPARTMENTSCHOOLSCHOOL LOOPCXCXPPPDRYERSDWH609,973 BTU/H -50 GPM91,496 BTU/H -7.5 GPM731,968 BTU/H -60 GPMPTHERMAL STORAGE TANKTST-1DISTRICT HEATING PUMPSP-1 P-2TTTTTBTU METERBOILER PLANTTT3"3"4"4"3"3"4"4"2"3"3"3"3"1 1/2"1 1/2"MMMMMMMMMMMMMMMMTPTTTTT2222222121344445544555555555555555555666676667778888878787910MMMMMMMMMMMMMMMM1111121313131314141414141516161616161616161616161616161616161616444444444444171819191919191920202020RADIANT FLOOR MANIFOLDS556P78M2FMBTU METERBOILER PUMPBP-1TTHTX55161644441919P55678MAUERV50% GLYCOLBTU METERFM TT16018058 GPMMMMMMMMMMMMMMMMM11MMMMMMMMMMMMMMMM1168 GPM7.5 GPMP-FDP-WTPAAAAAAAAAAAAAAAA7.5 GPMAAAAAAAAAAAAAAAA10 GPMAAAAAAAAAAAAAAAA20 GPMP-SCH160190MMMMMMMMMMMMMMMM60 GPM160 155185 180MMMMMMMMMMMMMMMM60 GPM160180155 160185175160155180 185#FLOW DIAGRAM NOTES1. THIS DIAGRAM SHALL TAKE PRECEDENCE OVER PLAN VIEWS FOR ACTUAL PIPING ARRANGEMENTS AND COMPONENTS REQUIRED.2. HOSE END DRAIN VALVE FOR MANUAL AIR VENT, AT ALL HIGH POINTS IN HEATING WATER SYSTEM.3. SEE ALSO 4/M601 FOR BASE MOUNTED PUMP DETAIL.4. P/T TEST PLUG, TYPICAL.5. UNION, TYPICAL.6. LIQUID FILLED PRESSURE GAUGE WITH SNUBBER, 1/4" BALL VALVE GAUGE COCKS AND 1/4" COPPER TUBING OR THREADED STEEL PIPE FROM PUMP SUCTION AND PUMP DISCHARGE.7. CONCENTRIC REDUCER AS REQUIRED, TYPICAL.8. INSTALL CONCENTRIC INCREASER ON DISCHARGE OF PUMP, TYPICAL.9. STRAINER, TYPICAL.10. 3/4" DRAIN W/HOSE FITTING AND CAP, TYPICAL.11. VENTURI STYLE MANUAL BALANCE VALVE. INSTALL WITH MANUFACTURER RECOMMENDED STRAIGHT PIPE UPSTREAM AND DOWNSTREAM OF VALVE.12. PRESSURE GAUGE, TYPICAL.13. 4" CONCRETE HOUSEKEEPING PADS SHALL EXTEND 4" BEYOND FOOTPRINT OF EQUIPMENT ON ALL SIDES.14. INSTALL FLANGE OR UNION AT EQUIPMENT CONNECTION. INSTALL CONCENTRIC REDUCER AS REQUIRED, TYPICAL.15. TAPS ON THE TANK SHALL BE WITHIN 6" OF THE TOP AND 6" OF THE BOTTOM.16. TEMPERATURE GAUGE, TYPICAL.17. TYPE UL 103 HT, STAINLESS STEEL ALL FUEL, DOUBLE WALL CHIMNEY.18. THREE WAY BOILER PROTECTION VALVE. PROVIDE LOCHINVAR MODEL LTV, 2-1/2" SIZE OR APPROVED EQUAL. PROVIDE REDUCERS AT VALVE. INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS.19. DDC TEMPERATURE OR PRESSURE SENSOR BY T.C. CONTRACTOR. WELLS BY MECHANICAL CONTRACTOR.20. CHECK VALVE, TYPICAL.21. NON SLAM, GLOBE STYLE CHECK VALVE, INSTALL WITH A MINIMUM OF 5 PIPE DIAMETERS OF STRAIGHT PIPE BETWEEN PUMP DISCHARGE AND CHECK VALVE.22. 3-WAY MODULATING CONTROL VALVE.23. PIPE RELIEF FULL SIZE TO FLOOR.24. RUN FULL SIZE OF OUTLET CONNECTION. TAG VALVE "BLOW DOWN OCCASIONALLY".25. AUTOMATIC AIR VENT WITH MINIMUM 3/8" DRAIN LINE.26. CAP BRANCH PIPING FOR FUTURE WASHATERIA DOWNSTREAM OF VALVEP867FUEL OIL BOILERB-2132223232425EXPANSION TANKET-1BOILER PUMPBP-2BOILER PLANT HEATING PUMPP-3AIR DIRT SEPARATORADS-1FUTURE WORK12626[]NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 4:27:54 PMWOOD FIRED BOILERSYSTEM HEATINGWATER FLOWDIAGRAMM20307.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/8" = 1'-0"M2031WOOD FIRED BOILER SYSTEM HEATING WATER FLOW DIAGRAM TTTTTHTX-SCH34P-SCH3"3"(E) B-1(E) B-1A4" CONCRETEHOUSKEEPINGPAD (TYP.)GSTO BUILDINGFROM BUILDING(E) ASGRGS3"3" 12" MAXTO/FROM BOILER PLANTTTTTMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMCXCXPNEWEXISTINGGSHEAT INJECTION PUMP HIP-SCH3"HTX-SCH______________M30113" HWS/R TO/FROM BOILER PLAN,SEE SITE PIPING PLAN FOR CONTINUATION3"3"3/M301SCHOOL KEY PLANGENERAL NOTESA. DO NOT RUN ANY PIPING OVER ELECTRICAL PANELS FROM PANEL TO STRUCTURE ABOVE AND FROM ACCESS SPACE TO 80" ABOVE FLOOR.B. TEMPERATURE SENSOR LOCATIONS SHALL BE REVIEWED WITH ARCHITECTURAL FIELD REPRESENTATIVE PRIOR TO INSTALLATION. INSTALL THERMOSTAT 48" ABOVE FINISHED FLOOR AS REQUIRED FOR PROPER EQUIPMENT INSTALLATION.C. CEILING SPACE THROUGHOUT THIS BUILDING IS VERY CONGESTED. COORDINATE ROUTING OF PIPING WITH ALL TRADES PRIOR TO INSTALLATION.NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 4:59:11 PMSCHOOL INTEGRATIONPLANSM30107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/4" = 1'-0"M3011ENLARGED SCHOOL BOILER ROOM PIPING PLANNOT TO SCALEM3012SCHOOL BOILER ROOM HEATING WATER FLOW DIAGRAM1/16" = 1'-0"M3013SCHOOL INTEGRATION PLANNORTH REFNORTH REF124SHEET NOTES1. COORDINATE FINAL WALL PENETRATION WITH WINDOW.2. RISE UP ON EXTERIOR AND THEN ELBOW INTO BUILDING. INSTALL INSULATED ENCLOSURE AROUND EXTERIOR RISER. SEE 3/M601.3. CORE DRILL THROUGH BOILER ROOM WALL. FIRE CAULK PIPE PENETRATION.4. INSTALL PIPING THROUGH CEILING FROM MAINTENANCE OFFICE TO BOILER ROOM. FIELD VERIFY FINAL ROUTING.5. DROP DISTRICT PIPING BETWEEN AIR HANDLING UNIT AND UPPER WALKWAY. INSTALL HEAT EXCHANGER ON FLOOR BELOW WALKWAY. TTTT______________M40123" HWS/R FROM BOILER PLANT1 1/2"HWRHWSHWRHWS3"31212HWRHWS3"1 1/2"(E) B-1 (E) B-2GRGSTO BUILDINGFROM BUILDING(E) HP-2(E) ASTO/FROM BOILER PLANT(E) HP-1TTTTGSGRCXCXPHTX-WTPHEAT INJECTION PUMP HIP-WTPGENERAL NOTESA. DO NOT RUN ANY PIPING OVER ELECTRICAL PANELS FROM PANEL TO STRUCTURE ABOVE AND FROM ACCESS SPACE TO 80" ABOVE FLOOR.B. TEMPERATURE SENSOR LOCATIONS SHALL BE REVIEWED WITH ARCHITECTURAL FIELD REPRESENTATIVE PRIOR TO INSTALLATION. INSTALL THERMOSTAT 48" ABOVE FINISHED FLOOR AS REQUIRED FOR PROPER EQUIPMENT INSTALLATION.C. CEILING SPACE THROUGHOUT THIS BUILDING IS VERY CONGESTED. COORDINATE ROUTING OF PIPING WITH ALL TRADES PRIOR TO INSTALLATION.NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 4:38:44 PMWTP INTEGRATIONPLANSM40107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/8" = 1'-0"M4011WTP INTEGRATION PLAN1/4" = 1'-0"M4012ENLARGED WTP BOILERROOM PIPING PLANNOT TO SCALEM4013WTP HEATING WATER FLOW DIAGRAMNORTH REFSHEET NOTES1. COORDINATE FINAL WALL PENETRATION WITH PROCESS PIPING INSIDE BUILDING.2. RISE UP ON EXTERIOR AND THEN ELBOW INTO BUILDING. INSTALL INSULATED ENCLOSURE AROUND EXTERIOR RISER. SEE 3/M6013. INSTALL PIPING THROUGH CULVERT INSTALLED AS PART OF WTP SITE WORK.4. COORDINATE HEAT EXCHANGER, PUMP, AND PIPING INSTALLATION WITH FUEL OIL DAY TANK.HTX-WTPP-WTP4 TTTT______________M5012______________M5013(E) B-1(E) B-2TO BUILDINGFROM BUILDINGGRGS 12" MAXTO/FROM BOILER PLANTTTTTCXCXPSTORAGE PLATFORM ABOVE BOILER ROOM1 1/4"NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 5:09:42 PMFIRE DEPT.INTEGRATION PLANSM50107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/8" = 1'-0"M5011FIRE DEPT. INTEGRATION PLAN1/4" = 1'-0"M5012ENLARGED FIRE DEPT. BOILERROOM PIPING PLANNOT TO SCALEM5014FIRE DEPT. BOILER ROOM HEATING WATER FLOW DIAGRAM1/4" = 1'-0"M5013ENLARGED FIRE DEPT. STORAGEPLATFORM PIPING PLAN OPEN AT TOPINSULATED BOOTHOSE END DRAINVALVE, MANUALAIR VENT (TYP)MANUAL VENTURIBALANCE VALVEHWRHWSBALL VALVESEE FLOOR PLANS FOR PIPE SIZESTHERMOSTATCYCLES FANHOSE END DRAINSTRAINERUNION (TYP)TFINISHED FLOORSEAL PIPE PENETRATIONS WATER TIGHTINSULATED PIPE ENCLOSURE. SEE ARCHITECTURAL.SEE CIVIL DRAWINGS FOR CONTINUATION 24" AFFPBUTTERFLY VALVE, TYPICALGAUGE PORTS ON FLANGES OF PUMPCOUPLING COVER4" CONCRETE BASEFLOORCONN. SIZE DRAIN VALVE, MIN 1" PIPE TO FLOOR DRAINSTRAINER BASKET PULL AREA, KEEP CLEARSUCTION DIFFUSER FURNISHED WITH PUMP1/4" MINI-BALL VALVES, NEEDLE TYPE NOT ALLOWEDBRAIDED STAINLESS STEEL FLEXIBLE PUMP CONNECTORFLOWFLOWUPON START-UP, RUN PUMP FOR 48 HOURS. REMOVE FINE MESH START-UP STRAINER AND WIRE TO PUMP FOR PROOF OF REMOVAL#DETAIL NOTES1. AFTER LEVELING BASE AND ALIGNING SHAFTS, GROUT PUMP BASE SOLID PER MANUFACTURERS RECOMMENDATION WITH NON SHRINKING GROUT.2. INSTALL CONCENTRIC INCREASER ON DISCHARGE OF PUMP. TYPICAL.3. SUCTION DIFFUSER WITH SUPPORT FOOT AND DRAIN VALVE. 4. LIQUID FILLED PRESSURE GAUGE WITH SNUBBER, 1/4" BALL VALVE GAUGE COCKS AND 1/4" COPPER TUBING OR THREADED STEEL PIPE FROM PUMP SUCTION, PUMP DISCHARGE, AND SUCTION DIFFUSER INLET.1234NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 5:10:10 PMMECHANICAL DETAILSM60107.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASSNOT TO SCALEM6011COMBUSTION AIR INTAKE LOUVERNOT TO SCALEM6012UNIT HEATER DETAILNOT TO SCALEM6013BUILDING PIPE PENETRATION DETAIL1/8" = 1'-0"M6014BASE MOUNTED PUMP DETAIL WDWDEDCBA124"4"4"4"WWWW4" FROM FCO ABOVE4" FROM FCO ABOVE4" W FA#SHEET NOTES1. PROVIDE ROUGH IN FOR FUTURE PLUMBING FIXTURESGENERAL NOTESA. DO NOT RUN ANY PIPING OVER ELECTRICAL PANELS FROM PANEL TO STRUCTURE ABOVE AND FROM ACCESS SPACE TO 80" ABOVE FLOOR.B. FIRE CAULK ALL PIPE PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS.NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 5:11:11 PMBOILER PLANTFOUNDATIONPLUMBING PLANP10007.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/8" = 1'-0"P1001BOILER PLANT FOUNDATION PLUMBING PLAN WDWDEDCBA12BP-11" CW FBCW1"1"CWFUEL OIL TANKFOSB-2NOT FOR CONSTRUCTION - PRELIMINARY DESIGNREVISIONS7/23/2021 5:11:44 PMDOMESTIC WATER &FUEL OIL PLANSP20007.23.2021© 2021 | ALL RIGHTS RESERVED95% PROGRESS SETDESIGNED BY | RATZDRAWN BY | HERBSTWOOD FIRED BOILER PLANTCITY OF NENANA, ALASKA | Project# NENANA_BIOMASS | L:\NENANA_BIOMASS\BIMCAD\RevitPROJECT# | NENANA_BIOMASS1/8" = 1'-0"P2001MAIN FLOOR DOM. WATER & FUEL OIL PLAN