Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Go Electric Nome Concept SLD v1
MG Concept Sheet: 1/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome MG Concept Sheet: 1/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome Gen1 (existing) M -+ 2MW or 4MW 1-hr Battery Storage (see separate sheets for details) 480V/ 3ph/ 60 Hz bus EWT Wind 900kW (existing) Loads M M Gen2 (existing) Gen3 (existing) Go Electric Scope of Supply includes: • LYNC Secure 500 kW (4) • DC Combiner Box (2) • Battery Storage (2) • AutoLYNC Microgrid Controller (1) • The 32' skid (1MW building block) is factory assembled, wired and tested Refer to separate data sheets for estimated dimensions and weights. Legend GoE Legend GoE Others Enclosure NEMA3R LYNC Secure 500 kVA (x4, 4 MVA total) -+ 1hr @ 2MW (x2) 20' ISO Container 2.0MW / 2.0MWh Sheet: 2/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome 2.0MW / 2.0MWh Sheet: 2/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome 800A To application (480V, 3ph) 800A 800A 800A 1600A 1600A DC Combiner (x2, 1600A) 800A MOB PR 800A MOB PR 800A MOB PR 800A MOB PR 1600A 1600A Disconnect (x2, 1600A) Switchgear 32' Skid -+ 50A, 480V Auxiliary 50A, 480V Auxiliary Note: All external wiring and switchgear provided by others. Go Electric Scope of Supply includes: • LYNC Secure 500 kW (8) • DC Combiner Box (4) • Battery Storage (4) • AutoLYNC Microgrid Controller (1) • The 32' skid (1MW building block) is factory assembled, wired and tested Refer to separate data sheets for estimated dimensions and weights. Legend GoE Legend GoE Others Enclosure NEMA3R LYNC Secure 500 kVA (x8, 4 MVA total) -+ 1hr @ 4MW (x4) 20' ISO Container -+ 4.0MW / 4.0MWh Sheet: 3/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome 4.0MW / 4.0MWh Sheet: 3/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome 800A To application (480V, 3ph) 800A 800A 800A 800A 800A 800A 800A 1600A 1600A 1600A 1600A DC Combiner (x4, 1600A) 800A MOB PR 800A MOB PR 800A MOB PR 800A MOB PR 800A MOB PR 800A MOB PR 800A MOB PR 800A MOB PR 1600A 1600A 1600A 1600A Disconnect (x4, 1600A) MV Transformer and Switchgear 32' Skid -+ -+ 50A, 480V Auxiliary 50A, 480V Auxiliary 50A, 480V Auxiliary 50A, 480V Auxiliary Note: All external wiring and switchgear provided by others. 1MW 32' Skid Building Block Concept Sheet: 4/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome 1MW 32' Skid Building Block Concept Sheet: 4/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome The 32' skid houses the 1MW building block. It includes the LYNC Secure 500kW PCS (x2), DC Combiner box (x2), AC Disconnect (x1) with the embedded AutoLYNC MG controller. The concept includes an insulated enclosure (not shown) to survive the cold temperature zone of Nome. The skid is factory assembled including the interconnections and tested before delivery to the site. When delivered to the site, the site work is limited to connecting to the Battery container (included in the GoE scope) and the application feed (switchgear and MV transformer provided by others). Concept Comms Sheet: 5/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome Concept Comms Sheet: 5/5 Project Name: Drawing Name: DATE: 2021-09-14 Drawn By: SL Rev: - Proprietary & Confidential Size: 11'’ x 17'’ Nome AutoLYNC Controller (embedded in LYNC Secure PCS) LYNC Secure PCS (4x or 8x) DC Combiner Box (2x or 4x) Battery Management System (2x or 4x) Local HMI Legend CAT 5/6 Modbus TCP Hardwire I/O CANBus Legend Provided by GoE Provided by Others Go Electric Scope of Supply includes: • Receives dispatch commands and provides monitoring (Sunspec/Mesa compliant) to/from SCADA • HMI (1) • BMS (4) • AutoLYNC Microgrid Controller (1) • DC Combiner Box comms (4) • LS5 (4 or 8) SCADA (E-house) Load Meter LS5 (PR) (4x or 8x) Wind Substation metering Note: All external wiring done by others. Woodward EasYgen (3x)