Loading...
HomeMy WebLinkAboutfl_xgi1500_10_03-02-2021 (1)Yaskawa Solectria Solar 1-978-683-9700 | Email: inverters@solectria.com | solectria.com Document No. FL.XGI1500.10 | 04/01/2021 | © 2021 Yaskawa America, Inc. SOLECTRIA 6-PACK 1 MWAC XGI 1500 RACK SOLUTION FACTORY INTEGRATED AND TESTED SOLECTRIA 6-PACK DESIGN Based around the Solectria XGI 1500 utility-scale string inverters, the 6-Pack is designed for high reliability, rapid deployment, and built to the highest standards of quality. The modular design provides six independent MPPT zones per megawatt for improved power-point tracking and improves system up time with a simplified maintenance plan. The XGI 1500 inverters provide advanced grid-support functionality and boast a true peak efficiency above 99%. The XGI 1500 inverters are the most powerful 1500V string inverters in the PV market. Designed and engineered in Lawrence, MA , the new Solectria 6-Pack features the XGI 1500 utility- scale string inverters that are Made in the USA with global components and compliant with the Buy American Act. The Solectria 6-Pack is the most robust, scalable building-block for state-of-the-art multi-MW solar plants. FEATURES • Six XGI 1500 utility-scale string inverters, 1MWac in total, pre-mounted on a robust, structural-steel rack • Fused AC combiner for the output from the six XGI 1500 inverters with 1200A fused load-break AC disconnect switch • Pre-assembled and pre-wired AC and communications cabling • Designed for rapid deployment • Scalable alternative to central inverters with convenient access for maintenance and service • True 99.0% peak efficiency • Advanced grid-support functionality Rule21/UL1741SA • Lowest O&M and installation costs • Access all inverters on site via WiFi from one location • Remote diagnostics and firmware upgrades • The XGI 1500 utility string inverter is Made in the USA with global components and Buy American Act (BAA) compliant OPTIONS • PV Source Circuit Combiners: 16, 20, 24, 26, 28 position • Available with 125kW, 150kW and 166kW inverter configurations. • Web-based monitoring • Extended Warranty SOLECTRIA 6-PACK TECHNICAL DATA DESIGN DETAILS SOLECTRIA 6-PACK Inverters Six XGI 1500-166/166 AC Combiner 3-PH AC Combiner with 6 @ 200A fused landing positions and 1200A fused load break disconnect, NEMA 4 enclosure Rack Structural steel, welded, with powder- coat paint finish, designed for ground mounting Pre-assembled, wired & tested AC output wiring from inverters to AC Combiner (type 4/0 AWG Cu); Communications wiring between Specification Data Single XGI 1500-166/166 SOLECTRIA 6-PACK DC Input Absolute Maximum Input Voltage 1500 VDC Maximum Power Input Voltage Range (MPPT)860-1250 VDC Operating Voltage Range (MPPT)860-1450 VDC Number of MPP Trackers 1 MPPT per inverter [6 MPPT total] Max Operating PV Current 197.7 A per inverter Max Operating PV Power 170 kW per inverter Max DC/AC Ratio | Max Rated PV Power 1.5 | 250 kW per inverter Max Rated PV Short-Circuit Current (ΣIsc x 1.25)320 A per inverter AC Output Nominal Output Voltage 600 VAC, 3-Ph AC Voltage Range -12% to +10% Continuous Real Output Power 166 kW 996 kW total Continuous Apparent Output Power 166 kVA 996 kA total Maximum Output Current 160A 960 A total Nominal Output Frequency 60 Hz Power Factor (Unity default)+/- 0.85 Adjustable Total Harmonic Distortions (THD) @ Rated Load < 3% Grid Connection Type 3-Ph + N/GND Fault Current Contribution (1 cycle RMS)192 A 1,152 A total Efficiency Peak Efficiency 99.0% CEC (pending) Average Efiiciency 98.5% Tare Loss < 1 W per inverter Environment Ambient Temperature Range -40°F to 140°F (-40°C to 60°C) De-Rating Temperature 113°F (45°C) Storage Temperature Range -40°F to 167°F (-40°C to 75°C) Relative Humidity (non-condensing)0 - 95% Operating Altitude 9,840 ft (3 km) For complete inverter specifications and further details, please visit www.solectria.com SPECIFICATIONS Yaskawa Solectria Solar 1-978-683-9700 | Email: inverters@solectria.com | solectria.com Document No. FL.XGI1500.10 | 03/02/2021 | © 2021 Yaskawa America, Inc.