Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4.2 Grant Lk IFIM Final Report June 2014 FINAL
Grant Lake Hydroelectric Project (FERC No. 13212) Aquatic Resources – Grant Creek Aquatic Habitat Mapping and Instream Flow Study Final Report Prepared for Kenai Hydro, LLC Prepared by McMillen, LLC June 2014 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 i June 2014 TABLE OF CONTENTS 1 Introduction ..............................................................................................................................1 1.1. Proposed Project Description ...............................................................................................1 1.2. Existing Information ............................................................................................................5 2 Study Objectives.......................................................................................................................6 2.1. Overall Goals Identified during Project Scoping .................................................................6 2.2. Specific Goals of Aquatic Habitat Mapping ........................................................................6 2.3. Specific Goals of the Instream Flow Study .........................................................................6 3 Study Area ................................................................................................................................7 4 Methods .....................................................................................................................................7 4.1. Grant Creek Aquatic Habitat Mapping ................................................................................7 4.2. Grant Creek Instream Flow Study .....................................................................................12 4.2.1. Overview of Physical Habitat Simulation (PHABSIM) Methodology .............. 12 4.2.2. Habitat Availability and Transect Selection ...................................................... 13 4.2.3. Habitat Utilization .............................................................................................. 15 4.2.4. Affected Species and Life Stages ...................................................................... 19 4.2.5. Field Methods .................................................................................................... 19 4.2.6. Connectivity of Habitats Within Reach 5 .......................................................... 20 4.2.7. Data Analysis ..................................................................................................... 21 4.2.8. Measured Flows for Grant Creek ....................................................................... 23 4.2.9. Flow Partitioning in Grant Creek ....................................................................... 24 4.2.10. Production of WUA for Grant Creek ................................................................. 33 5 Results .....................................................................................................................................33 5.1. Grant Creek Aquatic Habitat Mapping ..............................................................................33 5.2. Grant Creek Instream Flow Study .....................................................................................48 5.2.1. Weighted Usable Area ....................................................................................... 48 5.2.2. Reach 5 Connectivity ......................................................................................... 82 6 Conclusions .............................................................................................................................83 6.1. Grant Creek Aquatic Habitat Mapping ..............................................................................83 6.2. Grant Creek Instream Flow Study .....................................................................................83 6.2.1. Grant Creek Habitat ........................................................................................... 83 6.2.2. Connectivity ....................................................................................................... 84 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 ii June 2014 7 Variances from FERC-Approved Study Plan and Proposed Modifications ....................84 7.1. Grant Creek Aquatic Habitat Mapping ..............................................................................84 7.2 Grant Creek Instream Flow Study .....................................................................................85 8 References ...............................................................................................................................86 Appendices Appendix 1: Grant Creek Instream Flow Photos 1a: Transect Photos at 17 cfs Calibration Flow 1b: Transect Photos at 64 cfs Calibration Flow 1c: Transect Photos at 132 cfs Calibration Flow 1d: Transect Photos at 182 cfs Calibration Flow 1e: Transect Photos at 706 cfs Calibration Flow Appendix 2: HSC Curves 2a: Habitat Availability and Utilization 2b: HSC Curves Appendix 3: Calibration Details Appendix 4: Cross Sections, WSE, and Flow Hydraulics 4a: Reach 1 Main Channel 4b: Reach 1 Side Channel 4c: Reach 2 4d: Reach 3 Main Channel 4e: Reach 3 Side Channel 4f: Reach 4 Appendix 5: Weighted Usable Area Graphs 5a: Reach 1 Main Channel WUA 5b: Reach 1 Side Channel WUA 5c: Reach 2 WUA 5d: Reach 3 Main Channel WUA 5e: Reach 3 Side Channel WUA 5f: Reach 4 WUA Appendix 6: Reach 5 Connectivity 6a: Reach 5 Bed Profiles and Water Surface Elevation (WSE) 6b: Reach 5 Rainbow Trout and Dolly Varden Passage 6c: Reach 5 Coho and Sockeye Salmon Passage 6d: Reach 5 Chinook Salmon Passage List of Tables Table 4.2-1. Mesohabitat assessment sites (revised from HDR 2010). ....................................... 14 Table 4.2-2. Parameters used in the habitat utilization study. ...................................................... 19 Table 4.2-3. Substrate size classes used in the Grant Creek Instream Flow Study. .................... 19 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 iii June 2014 Table 4.2-4. Potential target species and life history stages to be modeled in the Grant Creek Instream Flow Study. ............................................................................................................ 20 Table 4.2-5. Species evaluated for connectivity in Grant Creek. ................................................ 21 Table 4.2-6. Calibration flows, Grant Creek (as measured in the mainstem). ............................. 24 Table 4.2-7. Calculations of flow in side channels, lobes, and tributaries, as related to the Grant Creek flow1. .......................................................................................................... 31 Table 4.2-8. Flow partitioning in Grant Creek for PHABSIM study. ......................................... 32 Table 5.1-1. Mesohabitats found in Grant Creek. ........................................................................ 47 Table 5.1-2. Aquatic habitats found in Grant Creek. ................................................................... 47 Table 5.2-1. Range of flows and models used to simulate Grant Creek WUA. .......................... 49 Table 5.2-2. Life history stages modeled at each Grant Creek transect. ..................................... 50 Table 5.2-3. Salmonid Spawning WUA, Reach 1 distributary. ................................................... 51 Table 5.2-4. Fry rearing WUA, Reach 1 distributary. ................................................................. 51 Table 5.2-5. Adult and juvenile rearing WUA, Reach 1 distributary. ......................................... 53 Table 5.2-6. Spawning WUA, Reach 1, mainstem. ..................................................................... 54 Table 5.2-7. Fry rearing WUA, Reach 1 mainstem. .................................................................... 55 Table 5.2-8. Adult and juvenile rearing WUA, Reach 1 mainstem. ............................................ 56 Table 5.2-9. Spawning WUA, Reach 2 mainstem. ...................................................................... 57 Table 5.2-10. Fry rearing WUA, Reach 2 mainstem. .................................................................. 58 Table 5.2-11. Adult and juvenile rearing WUA, Reach 2 mainstem. .......................................... 59 Table 5.2-12. Spawning WUA, Reach 3 mainstem. .................................................................... 60 Table 5.2-13. Fry rearing WUA, Reach 3 mainstem. .................................................................. 61 Table 5.2-14. Adult and juvenile rearing WUA, Reach 3 mainstem. .......................................... 62 Table 5.2-15. Spawning WUA, Reach 3 side channels. .............................................................. 63 Table 5.2-16. Fry rearing WUA, Reach 3 side channels. ............................................................ 64 Table 5.2-17. Adult and juvenile rearing WUA, Reach 3 side channels. .................................... 65 Table 5.2-18. Spawning WUA, Reach 3 combined. .................................................................... 66 Table 5.2-19. Fry rearing WUA, Reach 3 combined. .................................................................. 67 Table 5.2-20. Adult and juvenile rearing WUA, Reach 3 combined. .......................................... 68 Table 5.2-21. Spawning WUA, Reach 4. ..................................................................................... 69 Table 5.2-22. Fry rearing WUA, Reach 4. ................................................................................... 70 Table 5.2-23. Adult and juvenile rearing WUA, Reach 4. .......................................................... 71 Table 5.2-24. Discharge (cfs) for meeting salmonid passage criteria in Reach 5, Grant Creek. . 83 List of Figures Figure 1.1-1. Natural resources study area. ................................................................................... 3 Figure 3.0-1. Grant Creek reaches. ................................................................................................ 9 Figure 4.2-1. Grant Creek instream flow transect locations. ....................................................... 17 Figure 4.2-2. Aquatic habitats. ..................................................................................................... 25 Figure 5.1-1. Grant Creek mesohabitats. ..................................................................................... 35 Figure 5.2-1. Spawning WUA, Reach 1 distributary. .................................................................. 72 Figure 5.2-2. Fry rearing WUA, Reach 1 distributary. ................................................................ 72 Figure 5.2-3. Adult and juvenile rearing WUA, Reach 1 distributary. ........................................ 73 Figure 5.2-4. Spawning WUA, Reach 1 mainstem. ..................................................................... 73 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 iv June 2014 Figure 5.2-5. Fry rearing WUA, Reach 1 mainstem. ................................................................... 74 Figure 5.2-6. Adult and juvenile rearing WUA, Reach 1 mainstem. ........................................... 74 Figure 5.2-7. Spawning WUA, Reach 2 mainstem. ..................................................................... 75 Figure 5.2-8. Fry rearing WUA, Reach 2 mainstem. ................................................................... 75 Figure 5.2-9. Adult and juvenile rearing WUA, Reach 2 mainstem. ........................................... 76 Figure 5.2-10. Spawning WUA, Reach 3 mainstem. ................................................................... 76 Figure 5.2-11. Fry rearing WUA, Reach 3 mainstem. ................................................................. 77 Figure 5.2-12. Adult and juvenile rearing WUA, Reach 3 mainstem. ......................................... 77 Figure 5.2-13. Spawning WUA, Reach 3 side channels. ............................................................. 78 Figure 5.2-14. Fry rearing WUA, Reach 3 side channels. ........................................................... 78 Figure 5.2-15. Adult and juvenile rearing WUA, Reach 3 side channels. ................................... 79 Figure 5.2-16. Spawning WUA, Reach 3 combined. .................................................................. 79 Figure 5.2-17. Fry rearing WUA, Reach 3 combined. ................................................................. 80 Figure 5.2-18. Adult and juvenile rearing WUA, Reach 3 combined. ........................................ 80 Figure 5.2-19. Spawning WUA, Reach 4. ................................................................................... 81 Figure 5.2-20. Fry rearing WUA, Reach 4. ................................................................................. 81 Figure 5.2-21. Adult and juvenile rearing WUA, Reach 4. ......................................................... 82 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 v June 2014 Acronyms and Abbreviations ADCP Acoustic Doppler Current Profiler AEIDC Arctic Environmental Information and Data Center ARWG Aquatics Resource Work Group cfs cubic feet per second cm centimeter DLA Draft License Application FERC Federal Energy Regulatory Commission GIS geographic information system GPS Global Positioning System HABSIM Habitat Simulation HSC habitat suitability criteria HYDSIM Hydraulic Calibration Simulation IFIM Instream Flow Incremental Methodology KHI Kenai Hydro, Inc. KHL Kenai Hydro, LLC LA License Application LWD large woody debris MW megawatt NAVD 88 North American Vertical Datum of 1988 NGVD 29 National Geodetic Vertical Datum of 1929 NOI Notice of Intent OHV Overhead Vegetation PAD Pre-Application Document PHABSIM Physical Habitat Simulation PM&E protection, mitigation and enhancement Project Grant Lake Hydroelectric Project Q flow SZF stage of zero flow TLP Traditional Licensing Process TWG Technical Working Group RHABSIM Riverine Habitat Simulation USFWS U.S. Fish and Wildlife Service USGS U.S. Department of the Interior, Geological Survey VAF Velocity Adjustment Factor WUA weighted usable area WSE water surface elevation FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 vi June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 31212 1 June 2014 Aquatic Resources – Grant Creek Aquatic Habitat Mapping and Instream Flow Study Final Report Grant Lake Hydroelectric Project (FERC No. 13212) 1 INTRODUCTION On August 6, 2009, Kenai Hydro, LLC (KHL) filed a Pre-Application Document (PAD; KHL 2009), along with a Notice of Intent (NOI) to file an application for an original license, for a combined Grant Lake/Falls Creek Project (FERC No. 13211/13212 [“Project” or “Grant Lake Project”]) under Part I of the Federal Power Act. On September 15, 2009, the Federal Energy Regulatory Commission (FERC) approved the use of the Traditional Licensing Process (TLP) for development of the License Application (LA) and supporting materials. Per the TLP, KHL underwent consultation with the requisite stakeholders in relation to the development of a series of natural resource studies that were completed in 2013. As described in more detail below, the proposed Project has been modified to eliminate the diversion of water from Falls Creek to Grant Lake. The Aquatic Resources Study Plan was designed to address information needs identified in the PAD, during the TLP public comment process, and through early scoping conducted by FERC. This report specifically addresses the Instream Flow Study, one of the components to the Aquatic Resources investigations. Information from this report will be used to analyze flow-related Project impacts and to propose protection, mitigation, and enhancement (PM&E) measures. 1.1. Proposed Project Description The Project is located near the community of Moose Pass, Alaska, approximately 25 miles north of Seward and just east of the Seward Highway. It lies within Section 13 of Township 4 North, Range 1 West; Sections 1, 2, 5, 6, 7, and 18 of Township 4 North, Range 1 East; and Sections 27, 28, 29, 31, 32, 33, 34, 35, and 36 of Township 5 North, Range 1 East, Seward Meridian (U.S. Geological Survey [USGS] Seward B-6 and B-7 Quadrangles). The proposed Project would be composed of an intake structure at the outlet to Grant Lake, a tunnel, a surge tank, a penstock, and a powerhouse. It would also include a tailrace detention pond, a switchyard with disconnect switch and step-up transformer, and an overhead or underground transmission line. The preferred alternative would use approximately 15,900 acre- feet of water storage during operations between pool elevations of approximately 692 and up to 703 feet North American Vertical Datum of 1988 (NAVD 88)1. 1 The elevations provided in previous licensing and source documents are referenced to feet mean sea level in NGVD 29 [National Geodetic Vertical Datum of 1929] datum, a historical survey datum. The elevations presented in the Grant Lake natural resources study reports are referenced to feet NAVD 88 datum, which results in an approximate +5-foot conversion to the NGVD 29 elevation values. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 2 June 2014 An intake structure would be constructed approximately 500 feet east of the natural outlet of Grant Lake. An approximate 3,200-foot-long, 10-foot diameter horseshoe tunnel would convey water from the intake to directly above the powerhouse at about elevation 628 feet NAVD 88. At the outlet to the tunnel, a 360-foot-long section of penstock will convey water to the powerhouse located at about elevation 531 feet NAVD 88. An off-stream detention pond will be created to provide a storage reservoir for flows generated during the rare instance when the units being used for emergency spinning reserve are needed to provide full load at maximum ramping rates. The tailrace would be located in order to minimize impacts to fish habitat by returning flows to Grant Creek upstream of the most productive fish habitat. Two concepts are currently being evaluated for water control at the outlet of Grant Lake. The first option would consist of a natural lake outlet that would provide control of flows out of Grant Lake. A new low-level outlet would be constructed on the south side of the natural outlet to release any required environmental flows when the lake is drawdown below the natural outlet level. The outlet works would consist of a 48-inch diameter pipe extending back into Grant Lake, a gate house, regulating gate, controls, and associated monitoring equipment. The outlet would discharge into Grant Creek immediately below the natural lake outlet. In the second option, a concrete gravity diversion structure would be constructed near the outlet of Grant Lake. The gravity diversion structure would raise the pool level by a maximum height of approximately 2 feet (from 703 to 705 feet NAVD 88), and the structure would have an overall width of approximately 120 feet. The center 60 feet of the structure would have an uncontrolled spillway section with a crest elevation at approximately 705 feet NAVD 88. Similar to the first option, a low-level outlet would be constructed on the south side of the natural outlet to release any required environmental flows when the lake is drawn down below the natural outlet level. The outlet works would consist of a 48-inch diameter pipe extending back into Grant Lake, a gate house, a regulating gate, controls, and associated monitoring equipment. The outlet would discharge into Grant Creek immediately below the diversion structure. Figure 1.1-1 displays the global natural resources study area for the efforts undertaken in 2013 and 2014 along with the likely location of Project infrastructure and detail related to land ownership in and near the Project area. Further discussions related to specifics of the aforementioned Project infrastructure along with the need and/or feasibility of the diversion dam will take place with stakeholders in 2014 concurrent with the engineering feasibility work for the Project. Refined Project design information will be detailed in both the Draft License Application (DLA) and any other ancillary engineering documents related to Project development. The current design includes two Francis turbine generators with a combined rated capacity of approximately 5.0 megawatts (MW) with a total design flow of 385 cubic feet per second (cfs). Additional information about the Project can be found on the Project website: http://www.kenaihydro.com/index.php. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 31212 5 June 2014 1.2. Existing Information Information relating to aquatic resources has been collected during previous investigations into the potential development of hydroelectric generation on Grant Lake as well as during pre- licensing studies conducted by KHL in 2009 and early 2010. Previous FERC licensing efforts in the 1960s and 1980s for a proposed hydroelectric project at Grant Lake included studies of fish resources in Grant Lake and Grant Creek. Arctic Environmental Information and Data Center (AEIDC 1983) conducted fish sampling from 1981 to 1982 as part of a comprehensive environmental baseline study effort, and the U.S. Fish and Wildlife Service (USFWS 1961) conducted limited sampling from 1959 to 1960. An Instream Flow Study was completed in 1987 as part of a preliminary FERC LA prepared by Kenai Hydro, Inc. (KHI; not related to the current Kenai Hydro, LLC; Envirosphere 1987, KHI 1987a, and KHI 1987b). This effort included reports and written communications between KHI and state and federal agencies in 1986 and 1987 relative to a FERC LA for the proposed Grant Lake Hydroelectric Project (FERC No. 7633-002). Included were draft and final reports of a limited but complete Instream Flow Incremental Methodology (IFIM) investigation and negotiated minimum instream flows and ramping rates (Envirosphere 1987, KHI 1987a, and KHI 1987b). The collaborative process for a study of “instream flow” effects in Grant Creek was initiated in 2009 (HDR 2009a). The primary goal of the 2009 Instream Flow Study program was to establish a Technical Working Group (TWG) consisting of state and federal resource agency staff, KHL staff, and interested members of the local community. Once established, the TWG met three times during the 2009 study season to review the results of the 2009 aquatic baseline study efforts, discuss and agree upon an acceptable instream flow evaluation method, and request additional information to support that selection (HDR 2009a). A technical memorandum was drafted and shared with the Instream Flow TWG participants in 2009 detailing the results of the previous Instream Flow Study efforts (HDR 2009b). As part of the Instream Flow Study, and at the request of the TWG, a sampling event was conducted June 23–25, 2009 on Grant Creek to characterize the types of aquatic habitats used by resident fish and rearing fish (HDR 2009a). Aquatic habitat was described at each sample site by recording macro-, meso-, and micro-habitat characteristics. During the June sampling event, snorkeling was the primary method used to document fish presence. Electrofishing was used primarily to confirm species identification and calibrate fish length estimates (HDR 2009a). Collaboratively, the TWG and KHL decided to select an Instream Flow Study methodology based on the knowledge obtained from the summer 2009 aquatic resources and hydrology studies (HDR 2009a). Data and analyses from these studies were shared with the TWG in July and September. Based on the knowledge gained of Grant Creek’s fish and hydrologic resources, KHL presented a proposed instream flow approach to the TWG on September 23 (HDR 2009a). Physical stream data required for instream flow modeling, per the proposed approach, were collected at 18 transects during low- and mid-flow conditions in 2010. Where applicable, these data were used in the 2013 Instream Flow Study. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 6 June 2014 2 STUDY OBJECTIVES 2.1. Overall Goals Identified during Project Scoping Together with existing information, the goals of the study efforts were to provide baseline information, and where applicable, information on alternative flow regimes, which would allow an assessment in the study report of potential Project impacts on aquatic resources. These impact assessments are used to identify potential PM&E measures. The goals of this suite of studies were to provide supporting information on the potential resource impacts of the proposed Project that were identified during development of the PAD, public comment, and FERC scoping for the LA, as follows: Impact of Project operation on sediment transport (relative to the availability of spawning gravels) due to changes in flow in Grant Creek. Impact of Project operation (fluctuating lake levels in Grant Lake, changes in seasonal flow in Grant Creek, reduced flows between the dam and powerhouse on Grant Creek). 2.2. Specific Goals of Aquatic Habitat Mapping Prepare a geospatially referenced image of Grant Creek upon which aquatic habitat and fish use information can be superimposed. Develop a map of aquatic habitats that will provide a basis for describing the distribution of key habitat types. Identify important factors that influence fish use of key habitats for input to the instream flow analysis. Identify and map habitat with sufficient resolution so that the geographic information system (GIS) can be used to accurately calculate surface areas. 2.3. Specific Goals of the Instream Flow Study Assist impact analysis by modeling changes in key types of fish habitat relative to potential changes in stream flow. Provide a basis for planning Project instream flow mitigation measures. Provide a starting point for stream flow discussion. Provide supportable predictions of fish habitat availability in lower Grant Creek under various stream flow scenarios for key species and life history stages. Assess connectivity of the habitats present in Reach 5 (i.e., the Canyon Reach) to determine if reductions in stream flow in this reach potentially affect habitat connectivity. The purposes of this study were to fully delineate and map the aquatic habitats available in Grant Creek, identify important spawning and rearing fish habitats for both resident and anadromous salmonids, and describe the distinguishing factors that may influence fish use of the key habitats over those habitat units not occupied by fish in Grant Creek. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 7 June 2014 3 STUDY AREA The Project area is located near the town of Moose Pass, Alaska (population 206), approximately 25 miles north of Seward, Alaska (population 3,016), just east of the Seward Highway (State Route 9); this highway connects Anchorage (population 279,671) to Seward. The Alaska Railroad parallels the route of the Seward Highway and is also adjacent to the Project area. The town of Cooper Landing is located 24 miles to the northwest and is accessible via the Sterling Highway (State Route 1), which connects to the Seward Highway approximately 10 miles northwest of Moose Pass. Grant Creek is approximately 5,180 feet long (about one mile) and flows west from the outlet of Grant Lake to the narrows between Upper and Lower Trail lakes (Figure 3.0-1). The Grant Creek watershed is approximately 44 square miles and the watershed contains Grant Lake as well as a portion of the Kenai Mountain Range, with glacier-capped peaks as high as 5,500 feet. Grant Creek has a mean annual flow of 193 cfs, with an average gradient of 207 feet per mile; its substrate includes cobble and boulder alluvial deposits and gravel shoals (Ebasco 1984). In its upper half, Grant Creek passes through a rocky gorge with three substantial waterfalls (i.e., the break between Reaches 5 and 6); in its lower half, the stream becomes less turbulent as it passes over gravel shoals and diminishing boulder substrate (Ebasco 1984). For the purposes of the Grant Creek Instream Flow Study, the study area extends from the upstream border of Reach 5 downstream to the confluence of Grant Creek with the Trail Lakes. The study area includes only Grant Creek and its associated habitats (i.e., edge and mid-channel, main and side channels). This study area does not encompass the high water overflow channel, located between Reaches 1 and 2. 4 METHODS This section provides methods for both the Grant Creek aquatic habitat mapping and the Instream Flow Study in Sections 4.1 and 4.2, respectively. Further details can be found in the Aquatic Resources Study Plan (KHL 2013). 4.1. Grant Creek Aquatic Habitat Mapping The approach of this study involved three primary phases. During the first phase, the team spatially synthesized existing aquatic habitat and fish use data generated during various field efforts throughout the 2009 and 2010 field seasons. This exercise was completed primarily to identify spatial data gaps. In the second phase, the team then ground-truthed habitat data in the field, collected additional habitat and fish use data in Reaches 1 through 5, and incorporated other suitable habitat and fish use data collected in 2010 (e.g., Instream Flow Study). Finally, the team analyzed the suite of habitats and fish use data to identify important factors affecting distribution of fish. The primary tasks associated with this approach were as follows: Preparation of an office-based aquatic habitat map (i.e., based on habitat observations assembled throughout the 2009 and 2010 field seasons). FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 8 June 2014 Field surveys to ground-truth the office-based mapping effort and fill spatial data gaps relative to aquatic habitat and fish use in Reaches 1 through 4. Actual collection of fish habitat use information was accomplished by the resident and rearing fish tasks discussed in the Fisheries Report and the instream flow task. Incorporated aquatic habitat fish use data that identified key rearing, spawning, and feeding habitats for salmon and resident fish and potential overwintering habitats. Analyzed and identified the factors that may influence fish use of the key habitats over those habitat units not occupied by fish in Grant Creek. The office-based mapping exercise incorporated existing habitat data overlain by fish use data into a spatial format, using ArcMap© GIS software. The initial dataset included habitat units mapped during a microhabitat fish use reconnaissance study completed in June 20092. The team plotted locations of salmon spawning activity recorded during 2009 foot surveys and high-use spawning areas identified by historical data (Ebasco 1984). The teams used the preliminary spatial fish habitat information to catalog and identify gaps in coverage. The team conducted surveys to ground-truth the preliminary aquatic habitat delineation (i.e., generated through the office-based exercise), redraw mapping boundaries where appropriate, and confirm the location of habitat areas that are in need of additional study. The team delineated aquatic habitats at the mesohabitat level and subcategory scale, consistent with the approach developed for the approved 2009 habitat reconnaissance study. The team identified key fish habitats in Grant Creek, based on observed fish use. This was accomplished by analyzing the microhabitat fish use data collected in support of the habitat mapping study, data collected in support of the Instream Flow Study, and data collected in 2009 during the reconnaissance study (HDR 2009a). These data were incorporated into the spatial dataset. Other fish use habitat datasets (e.g., foot surveys, telemetry surveys, electrofishing) were considered when developing key habitat designations. Surface areas of habitat types were calculated as needed using the capability of the GIS software. Definition of Terms Mesohabitat types were identified and mapped in 2009/2010. The following definitions are provided for these habitat types (Overton et al. 1997, unless otherwise noted): Backwater: Pool formed by an eddy along a channel margin downstream from obstructions such as bars, rootwads, or boulders, or resulting from back-flooding upstream from an obstructional blockage. Also, a body of water, the stage of which is controlled by some feature of the channel downstream from the backwater, or in coves or covering low-lying areas and having access to the main body of water. 2 The 2009 fish microhabitat use reconnaissance study was initiated to gain insight into the types of habitats that fish occupy in Grant Creek. The team identified discrete microhabitat types and sampled for fish presence at 16 sites in Grant Creek. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 31212 11 June 2014 Cover: Suspended material covering the land or water; measured as a percentage of the surface area when looking from above. ○ Fish: Anything that provides protection from predators or improves adverse conditions of stream flow or seasonal changes in metabolic costs. This may be overhead cover or submerged cover and it may be used for escape, feeding, hiding, or resting. ○ Overhead: Whitewater, surface turbulence, bank vegetation, tree branches, floating logs, or other debris touching or within 0.3 m of the water surface. ○ Submerged: Large woody debris, other organic debris, ledges, or aquatic vegetation below the water surface. Fast water: Habitat types consist of turbulent (cascade, step run, high gradient riffle, and low gradient riffle) and non-turbulent (runs and glides). Large woody debris (LWD): Large pieces of relatively stable woody material located within the bankfull channel and appearing to influence bankfull flows. These are categorized as singles, aggregates, or root wads. is different than criteria for AK]. ○ Aggregate: Two or more clumped pieces, each of which qualifies as a single piece. ○ Rootwad: Root mass or boles attached to a log less than 3 m in length. Pocket: Small bed depressions, often less than 30 percent of wetted width, formed around channel obstructions (boulders, logs, irregular bank, jutting peninsulas, and so forth) within fast water habitat types. Pool: A habitat type formed by either scour that has carved out a depression in the channel, or a location where the channel has been dammed. Surface velocities may be slow to fast, but subsurface velocities tend to be slow. Pools are characterized by a head crest (upstream break in slope) and a tail crest (downstream break in slope). Types of pools include the following: ○ Dammed: Pool formed by downstream damming action. Dam pools can be located in the main channel (or side channel) or backwaters. ○ Scour: Pool formed by scour action when flowing water impinges against and is diverted by a streambank or channel obstruction (rootwad, woody debris, boulder, bedrock, and so forth). Scour pools may be lateral scour, mid-scour, plunge, or underscour pools. ○ Lateral scour: A pool formed by the scouring action of the flow as it is directed laterally or obliquely to one side of the stream by a partial channel obstruction, such as a gravel bar or wing deflector, or by a shift in channel direction. ○ Mid-channel scour: A pool formed by the scouring action of the flow as it is directed toward the middle of the channel by a partial channel obstruction. ○ Plunge: A pool formed by scouring action from vertically falling water. ○ Underscour: A pool formed by scouring under an obstruction, such as a log. Sometimes called an upsurge pool. Riffle: Shallow rapids where the water flows swiftly over completely or partially submerged obstructions to produce surface agitation, but where standing waves are absent. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 12 June 2014 Side channel: A lateral channel with an axis of flow roughly parallel to the mainstem and which is fed by water from the mainstem; a braid of a river with flow appreciably lower than in the main channel. Slow water: Habitat types consist of dammed (main and backwater) and scour (lateral, mid-channel, plunge, and underscour). Stream margin: edge of the wetted perimeter. Undercut bank: A bank that has its base cut away at least 5 centimeters (cm) by the water or has been artificially made and overhangs directly above the water surface. 4.2. Grant Creek Instream Flow Study The Grant Creek Instream Flow Study approach to be applied to lower Grant Creek Reaches 1–4 was collaboratively developed based on input from the Instream Flow TWG. Public meetings of the TWG were held in April and September 2009, and a conference call was held in May 2009; input and suggestions were solicited during these meetings and also through e-mail and phone communications with the TWG and TWG members. Subsequently, KHL met with the stakeholders in December 2012 to update study plans and to prepare for the 2013 field season. As agreed to during the previous 2010 investigations, the selected Instream Flow Study approach emphasized a detailed study of utilized habitat types and addressed the desire of the TWG to examine how important individual habitat units may be affected by changes in flow due to the operation of the Project. Rather than applying a typical habitat study that generalized mesohabitat units in a study reach, the agreed-upon approach used several techniques to tie physical microhabitat to flow and timing, and applied in situ knowledge of fish habitat use in Grant Creek as tools to determine potential effects of the Project. The selected approach included the following: A series of single transect analyses, with each transect going through a known fish use area such as high-use spawning or rearing areas. Fish studies that helped identify microhabitat factors that affected fish use within each key habitat type. Monitoring temperature and flows at multiple locations in Grant Creek in conjunction with the Water Resources study program to establish baseline stream flow and temperature changes. The 2013 Instream Flow Study built upon the investigations that began in 2009. The following sections describe methods used for the various components to complete the instream flow assessment. 4.2.1. Overview of Physical Habitat Simulation (PHABSIM) Methodology The instream flow methodology is based on the premise that stream-dwelling fish are more often found in a certain range of depths, velocities, substrates, and cover types, depending upon the species and life stage, and that the availability of these preferred habitat conditions varies with stream flow. Physical Habitat Simulation (PHABSIM) is designed to quantify potential physical FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 13 June 2014 habitat available for each target fish species and life stage of interest, at various levels of stream discharge, using a series of modeling programs initially developed by the U.S. Fish and Wildlife Service (USFWS). Major components of the methodology include (1) study site and transect selection; (2) transect weighting; (3) field collection of hydraulic data; (4) hydraulic simulation to determine the spatial distribution of combinations of depths and velocities with respect to substrate and cover under a variety of discharges; and (5) habitat simulation, using habitat suitability criteria (HSC) to generate an index of change in habitat relative to change in discharge. The product of the habitat simulation is expressed as weighted usable area (WUA) for a range of simulated stream discharges. It is important to recognize that the product of an instream flow analysis is not a set value, but rather is a range of values to be used as a tool for discussing and determining a range of stream flows that will meet the needs of the affected resources. 4.2.2. Habitat Availability and Transect Selection The purpose of the habitat availability component of the Instream Flow Study was to measure available habitat at proposed mesohabitat sites as a function of discharge (Table 4.2-1). Available habitat was correlated to results of the habitat utilization component described in Section 4.2.3. This information was cross-referenced with historic hydrographs, recent hydrologic data, and potential flow scenarios in Grant Creek to determine discrete time periods when the habitat unit may be available for its designated use. Cross section geometry, substrate, cover, and hydraulic data were measured at each transect using techniques developed for PHABSIM. Application of PHABSIM techniques on Grant Creek is different from most other studies because transects were selected on important habitat units with known fish use, as opposed to a standard PHABSIM approach that attempts to represent all habitat units regardless of unique importance or known fish use. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 14 June 2014 Table 4.2-1. Mesohabitat assessment sites (revised from HDR 2010). Transect Channel Type Fish Habitat Site Notes 100 Rearing Distributary R1FH11 Linear transect, slow water 110 Rearing Distributary R1FH12 Linear transect, slow water, large woody debris (LWD) 120 Spawning Riffle Spawning riffle 130 Rearing Main R1FH05 Main channel fast water, Side channel, small mid channel bar, vegetated, LWD upstream 140 Rearing Main R1FH05 Main channel fast water, Side channel, small mid channel bar, vegetated, LWD upstream 150 Rearing Main R1FH13 Woody debris, left bank (LB), fast water main channel 160 Rearing Main R1FH13 Woody debris, LB, fast water main channel 200 Rearing Main R1FH06 Backwater lobe 210 Rearing Secondary R2FH10 Small tertiary channel 220 Rearing Main R2FH10 Main channel, fast water, right bank (RB) undercut bank 230 Rearing Main/ Secondary R2FH10 Main channel, fast water, undercut bank on RB, surveyed across island to backwater pool 300 Rearing Main Backwater lobe 310 Spawning Main R2FH10 Backwater, low velocities, main channel, fast and deep 320 Rearing Secondary R3FH09 LWD, Secondary channel and spawning 330 Rearing Secondary/Tertiary R3FH09 LWD, Secondary channel, spawning and Tertiary channel 400 Rearing Main R3FH16 Small side channel, cobble/gravel bar - no vegetation, very deep undercut bank 410 Rearing Main R3FH16 Small side channel, cobble/gravel bar - no vegetation 430 Spawning Main R5FH15 Pool, deep fast, LWD upstream, shallow slow margin shelf Channel Type Count Percent Rearing Distributary 2.0 11.1 Rearing Secondary/Tertiary 3.5 19.4 Spawning Main 3.0 16.7 Rearing Main 9.5 52.8 Total 18.0 Head pins, tail pins, and a temporary benchmark were set at each transect. Survey instrument and photo points were established and marked. Each transect site was fixed using a handheld Global Positioning System (GPS). Habitat unit cross sectional profiles were surveyed using standard differential survey techniques. Cross section survey points divided the profile into 1 – 3 foot cells, depending upon changes in elevation, substrate, or hydraulic conditions. Dominant and subdominant substrate and cover were recorded within each cell. Water surface elevations (WSE) at each transect were measured using a survey instrument at 3 to 5 discharges in the mainstem of Grant Creek, ranging from a low flow of approximately 17 cfs to FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 15 June 2014 a high flow of approximately 700 cfs. WSE were measured at 3 – 4 discharges in the side channels, ranging from a low flow of 1.4 cfs to a high flow of approximately 114 cfs. Mean column velocities were measured within each cell at a high flow of 170 to 200 cfs (as measured at the Grant Creek stream gage), or the highest possible flow within practical and safety limitations. Numerous photos from established photopoints were taken at each of the 3 to 5 flow levels. Cross sections (Table 4.2-1) were located during a site visit on September 24, 2009. The locations were set based on presence of physical microhabitat (i.e., undercut bank, overhead cover, bedrock outcrops, and pocket water) and observations of fish during the site visit and during snorkeling studies. Locations of the modeled transects are shown in Figure 4.2-1. Photos of IFIM transects at the calibration flows are included in Appendix 1. 4.2.3. Habitat Utilization The purpose of the habitat utilization component of the Instream Flow Study was to determine which meso- and microhabitat factors the fish in Grant Creek occupied to assess the impacts, if any, the Project would have on instream habitat. To maximize the knowledge of habitat selection factors for fish in Grant Creek, observations were made at the locations of the transects and fish habitat sites, as described in the previous section. Fish spawning and rearing microhabitat values were recorded at programmatically-selected sites in Reaches 1 through 4. Measured microhabitat use parameters varied by habitat units. During the Instream Flow TWG meeting on September 23, 2009, Table 4.2-2 was developed with input from TWG members. In 2013, measurements of 99 spawning pairs of Sockeye salmon were taken at flows ranging from 338 cfs – 469 cfs in the mainstem and 28 cfs – 74 cfs in the side channels. Measurements of 47 Coho salmon spawning pairs were taken at flows ranging from 169 cfs – 285 cfs; however, all but 4 of the observed Coho spawning occurred at flows ranging from 169 cfs – 179 cfs. For this reason, McMillen extended the probability of use curves to reflect the upper end of optimum utilization (i.e., value of 1.0) in the Cooper Creek curves. Only three Chinook salmon pairs were observed spawning; these were discarded and literature-based curves were used. Information relating to site-specific HSC was developed from these data and used in combination with HSC curves available in the existing literature and professional judgment to determine final HSC curves to be used in modeling. Development of final HSC curves was pursued as a collaborative effort with the Aquatics Resource Work Group (ARWG), which has been established to review aquatic data in 2014. HSC curves were combined with the transect measurements and mesohabitat characterizations to model changes in habitat as a function of discharge. Methods for normalizing values for HSC curves, using habitat utilization and habitat availability, are described in WDFW/WDOE (2013). HSC curves are found in Appendix 2. Habitat utilization data are covered extensively in Aquatic Resources Study – Grant Creek, Alaska Fisheries Assessment, Final Report (KHL 2014a). FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 16 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 31212 19 June 2014 In areas of observed spawning use, depth and mean column velocity were recorded. Dominant and subdominant types of substrate size were recorded by visual estimate, using categories as described in Table 4.2-3. Table 4.2-2. Parameters used in the habitat utilization study. Habitat Use Function by Life History Habitat Use Parameters to Measure Salmon rearing Depth, velocity, cover, wetted perimeter, habitat connectivity Salmon spawning Substrate, depth, velocity, temperature Rainbow Trout spawning Substrate, depth, velocity, temperature Incubation Depth, wetted perimeter, temperature Resident rearing and spawning Salmon rearing will be used as a surrogate Table 4.2-3. Substrate size classes used in the Grant Creek Instream Flow Study. Substrate Type Size (inches) Organics, vegetation -- Clay, silt (fines) <0.002 Sand (coarse) 0.002 - 0.07 Small gravel 0.07- 0.30 Medium gravel 0.30 – 1.25 Large gravel 1.25 – 2.5 Small cobble 2.5 – 5.0 Large cobble 5.0 – 10.0 Boulder >10.0 Bedrock -- 4.2.4. Affected Species and Life Stages Fisheries resources of primary concern in Grant Creek are commercial and game fish that include Chinook (Oncorhynchus tshawytscha), Coho (O. kisutch), and Sockeye (O. nerka) salmon, Rainbow trout (O. mykiss), and Dolly Varden char (Salvelinus malma). All of these species have been documented to utilize portions of the study area during some part of their life cycles. Fish use Grant Creek in a variety of ways. Adults of the anadromous species use Grant Creek for upstream migration, spawning and rearing. Salmonid fry and juveniles use the creek for rearing and as a downstream migration corridor on their journey toward the sea. Proposed species and life stages for the Instream Flow Study are found in Table 4.2-4. 4.2.5. Field Methods Transects were oriented across the selected habitat unit to best capture the average condition of interest in that unit, such as spawning or rearing potential. Field data were collected at the Grant Creek transects at a high, several middle, and low flows for model calibration purposes. Generally, all field data were taken using the standard procedures described in Trihey and Wegner (1981) and Bovee (1982). Not all transects used the same benchmark. Head pin FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 20 June 2014 elevations, hydraulic slopes, stage of zero flow (SZF), WSEs, and channel cross sections were measured using a Topcon auto level and stadia rod, using standard survey techniques. The surveyor tied these features to the transect benchmark to the nearest 0.01 feet. Table 4.2-4. Potential target species and life history stages to be modeled in the Grant Creek Instream Flow Study. Species Spawning Fry Rearing Juvenile Rearing Adult Rearing Sockeye Salmon Coho Salmon Chinook Salmon Rainbow Trout Dolly Varden Char A series of field measurements were taken in 2010. Due to the possibility of changes in bed profiles and hydraulic controls (i.e., SZF), all transects were resurveyed to determine if head or tail pins had moved or if high flow events since 2010 had altered the stream profile or the hydraulic controls. In addition, KHL collected discharge and stage data at a wide variety of flows in order to extend the extrapolation range of the models. Measurements in the main channel ranged from a low of 17 cfs, to a high of approximately 700 cfs. Depth and velocity distributions at the calibration flows were measured using a digital, Swoffer brand, propeller-type velocity meter mounted on a standard top-set wading rod. Velocity was measured at sixth tenths of the depth when depth was less than 2.5 feet and at two tenths and eight tenths of the depth where depths equaled or exceeded 2.5 feet, or when flow was influenced by an upstream obstruction. If prior investigations had adequate depth and velocity measurements and there were no bed elevation changes, KHL used those measurements. If the number of measurements was not adequate or if the bed profile had changed, KHL made additional measurements within the channel. Temporary staff gage levels and the time of day were recorded at the beginning and end of each transect measurement to note changes in stage; the outside staff height at the Grant Creek stream gage was also recorded. Substrate was classified using a three-digit code representing the most abundant particle size, the second-most abundant particle size, and the percentage of the most abundant particle size (see Table 4.2-3 for substrate classification). 4.2.6. Connectivity of Habitats Within Reach 5 During the 2013 field season, two transects (T510 and T520) that represented the areas sensitive to changes in flow and stage were selected and measured in the canyon (i.e., Reach 5). Cross sections were surveyed at both transects. Head and tail pins on each bank as well as a benchmark were surveyed to establish relative elevations. A tape was stretched horizontally across the channel and attached to the head and tail pins. With an auto level and stadia rod, elevations of the streambed and banks were surveyed at regular intervals along the tape and WSEs were surveyed at locations where accurate measurements could be obtained. Water surface elevations were surveyed at flows ranging from 17 cfs – 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 21 June 2014 Riverine Habitat Simulation (RHABSIM) uses a power function to calculate the stage-discharge relationship at transects. This stage/discharge relationship was used to calculate the water surface elevation for each simulated flow. Station location, streambed elevations, discharges, water surface stage, slope, and SZF were entered into the PHABSIM hydraulic model; depths at each station were simulated for the modeled range of flows. Depths equal to or exceeding the passage depth criteria for each species were tallied at each modeled flow. Adjoining cells with depths equal to or exceeding the criteria were also tallied. The total width of the cells in each of these categories at each modeled flow was divided by the total wetted width at each flow to compute the percent of the transect that is currently passable. Table 4.2-5 shows the species considered at each stream and the passage depth criteria used to evaluate fish passage success. Connectivity of the various pools and channels was measured and assessed using the Oregon Method (Thompson 1972). After 10 years of research on depth and velocity in streams in Oregon, Thompson concluded that the depth over “the shallow bars most critical of adult passage” was the feature that determined the likelihood of successful migration. Thompson recommends a minimum depth of 0.6 feet for large trout and 0.8 feet for Chinook salmon to achieve successful passage. The “Oregon Method”, as it is now commonly called, concludes that the passage flow is adequate when the depth criterion is met on at least 25 percent of the transect width and on at least a 10 percent continuous portion. Transect data were collected to determine where connectivity meets these criteria and where it does not. Connectivity was assessed concurrently with the Instream Flow Study conducted downstream in Reaches 1 – 4, at the same range of flows. Table 4.2-5. Species evaluated for connectivity in Grant Creek. Species Evaluated Minimum Depth Criteria Chinook Salmon 0.80 feet Coho and Sockeye Salmon 0.60 feet Dolly Varden Char and Rainbow Trout 0.40 feet 4.2.7. Data Analysis 4.2.7.1. Hydraulic Modeling Analysis and integration of physical stream measurements and habitat preference criteria require the use of a group of the RHABSIM (Riverine Habitat Simulation) computer programs. There are two main programs in the RHABSIM library: the hydraulic model (called HYDSIM), and the habitat model (called HABSIM). Hydraulic modeling involves two sequential steps. The first step is to develop a stage-discharge relationship, and the second step is velocity calibration. The stage is the height of the water surface elevation (WSE) at a location (in this case, at each transect). At a minimum of three widely separated calibration flows, stages and flows should be measured and recorded; generally, FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 22 June 2014 the lower flow should be half or less of the next higher flow. A power function predicts the WSE and calculates the depth of the water at that flow by subtracting the bed profile from the WSE. At each point (station) along a transect, a velocity calibration is needed to estimate velocity. An average velocity for the river can be calculated at a transect if the flow and the cross sectional area of the river are known at the transect. Flow (Q, in cubic feet per second) = cross sectional area (A) X average velocity (V), and A=depth X width; thus V = Q/A. Velocity calibration allows fine-tuning of velocity distribution across a transect. Velocity is not uniform across a transect, but faster in some places and slower in others. Over a range of flows, it is possible to modify (either increase or decrease) the “cell” velocity relative to the average velocity by using a measured velocity to indicate relative resistance to flow or roughness. Successful velocity calibration generates reasonable approximations of the actual velocity measurements at the calibrated and extrapolated flows. Other velocity calibration methods are also available. The Habitat Simulation (HABSIM) program integrates the simulated hydraulic information from Hydraulic Calibration Simulation (HYDSIM) with HSC curves and quantifies habitat availability over a range of flows for the specified target species and life stages. Habitat quantification is expressed as an index called WUA, and is given in units of square feet of habitat per 1,000 linear feet of stream. 4.2.7.2. Hydraulic Modeling Procedures McMillen calibrated the Grant Creek hydraulic models using methods described below. All of the input decks were initially processed using the Problem Report subroutine of the Field Data Entry Module of RHABSIM. This program looks for errors in data placement and produces a hard copy of the pertinent information needed to run the model, including transect weighting factors, slopes, SZF, and WSE. 4.2.7.3. Hydraulic Model Calibration One of the goals of the hydraulic simulation is to have the model accurately simulate the measured velocities and depths at the calibration flows, while minimizing changes to the data. In this regard, only minor changes were made to the instream flow data in order for the model to more accurately predict cell velocities at the simulated flows. Only minor changes were made to the original input data. Most revisions fell into one of four categories: 1. Replacing a measured velocity of 0.0 feet/second with a velocity of 0.1 feet/second in some cells where there was depth but no measured velocity. The model “sees” a measured zero velocity as a blank and will attempt to fill that cell with a velocity based on a mass balance equation for the transect, taking into consideration slope, adjacent velocities, and the resistance of the bed of a channel to the flow of water in it (referred to as Manning’s N, a roughness coefficient). Replacing a measured velocity of 0.00 with a velocity of 0.01 or 0.1 often corrects this problem. 2. Changing the Manning’s N value to either reduce or increase the velocities in the given cell. Edge cells are often assigned high Manning's N values by the model. The FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 23 June 2014 high N values slow the velocities through these cells, giving an unrealistic simulation of velocities. In these instances, the N values were manually reduced. 3. Adjusting the bed elevations at the stream margin cells slightly. 4. Changing the SZF in certain instances when it improved the mean error of the stage discharge relationship. Changes were kept to a minimum and the decks were revised only when specific changes improved model performance. The goal is to have the simulated velocities fall within 20 percent or 0.2 feet/second of the measured velocity, whichever is greater. Mean error (for both given and predicted discharges), ratio of measured versus predicted discharges, and B coefficients were all within the acceptable limits for PHABSIM calibration. Velocity Adjustment Factors (VAFs) are generally a measure of how well a model simulates the actual velocities. In a one-velocity set model, however, the VAFs are actually adjustment factors of discharge, not velocities, and a wider range of values is acceptable. A summary of VAFs and calibration details for all transects is presented in Appendix 3. Cross section, WSE, and flow hydraulic summaries are found in Appendix 4. All VAF values were within the acceptable range for one-velocity set models. A one-velocity set model tends to model velocities better in a downward, or decreasing direction; as the discharges are increased above the calibration flow measurement, drag on the banks (in the form of higher roughness coefficients) tends to underestimate habitat. Another calibration method, known as depth calibration, sets Manning’s N values to 0.06 and simulates velocities so that the thalweg and deeper areas are assigned higher velocities. This method tends to overestimate habitat slightly. To balance these differing WUAs, the results are averaged together for the higher flow ranges. 4.2.7.4. Transect Weighting In a typical PHABSIM study, transect weighting is dictated by the frequency of that particular mesohabitat type present in the study reach. Per previous consultation with the Instream Flow TWG, transects were placed on locations of known salmonid utilization (see Section 4.2), rather than representing gross habitat frequencies. Given this approach, all transects were weighted equally, so relative weighing and lengths were the same for all transects. 4.2.8. Measured Flows for Grant Creek When possible, McMillen collected up to five sets of stage/discharge data at each transect. This was in addition to two sets of stage/discharge measurements taken in 2010. In some instances, distributary or side channel transects were either dry or still frozen, precluding some measurements. Additional WSE measurements were taken in these two areas at a Grant Creek flow of approximately 440 cfs. Due to channel changes at Transect 330, a new calibration measurement was also taken at this flow. KHL collected WSEs at each transect at a very high flow (approximately 700 cfs, as measured by an Acoustic Doppler Current Profiler [ADCP]). These flows and a WSE at each transect were used to generate the stage-discharge relationships. The calibration flows are shown in Table 4.2-6 for each transect. Figures 4.2-1 and 4.2-2 show FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 24 June 2014 the locations of these transects, as well as the main channel, side channels, and Reach 1 distributary. Table 4.2-6. Calibration flows, Grant Creek (as measured in the mainstem). Area Measured Flows (cfs) 17 64 132 182 440 700 Main Channel Distributary Dry/Frozen Dry Dry Reach 3 Side Channels Frozen 4.2.9. Flow Partitioning in Grant Creek As shown in Figure 4.2-1, Grant Creek below the powerhouse consists of a main channel, several side channels, two low-velocity lobes (T200 and T300), a backwater channel (T210 and T230), a high flow overflow channel (when flows are approximately 450 cfs), and a distributary in Reach 1 that does not get wetted until approximately 190 cfs (T100 and T110). The Figure 4.2-2 map series also shows these features. The side channels in Reaches 2 and 3 are wetted at all flows; however, the smaller side channels may be frozen over in winter at low flows and temperatures. All of these channels affect flow at the Grant Creek measured transects. KHL ran regression analyses in order to partition the flow appropriately for the PHABSIM model. Table 4.2-7 summarizes the calculated partitioning of flow for each area of Grant Creek; Table 4.2-8 presents the table of flows used for the PHABSIM analysis. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 31212 31 June 2014 Table 4.2-7. Calculations of flow in side channels, lobes, and tributaries, as related to the Grant Creek flow1. Transect % Flow r2 Comments T100/110 0.99% 0.951 Dry at flows < 190 cfs Overflow Channel ~ 1.70% N/A Activates at ~ 450 cfs; affects Reach 1 main channel transects T200 8.94% N/A % of main channel at calibration measurement T210/230 Side Channel (SC) 0.00% N/A Backwater with no velocity; WSE is dependent upon T200 T300 1.71% N/A % of main channel at calibration measurement T310 GC-T330 N/A All Reach 2/3 side channels flow represented by T330 T320 15.81% 0.990 T330-M 15.06% 0.986 Main Channel of T330 T330-2nd 0.0844 T330-M 0.934 Secondary channel; percent of T330-M flow T330-3rd 0.0219 T330-M 0.839 Tertiary channel; percent of T330-M flow Notes: 1 Flow from Grant Creek stream gage unless otherwise noted. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 32 June 2014 Table 4.2-8. Flow partitioning in Grant Creek for PHABSIM study. Reach 2/41 T100/110 T200 T300 T310 T320 T330- MC T330-2 T330-3 Reach 12 10 0.89 0.17 8.33 1.58 1.51 0.13 0.03 10 20 1.79 0.34 16.67 3.16 3.01 0.25 0.07 20 30 2.68 0.51 25.00 4.74 4.52 0.38 0.10 30 40 3.57 0.68 33.33 6.33 6.03 0.51 0.13 40 50 4.47 0.85 41.67 7.91 7.53 0.64 0.16 50 60 5.36 1.02 50.00 9.49 9.04 0.76 0.20 60 70 6.26 1.19 58.33 11.07 10.54 0.89 0.23 70 80 7.15 1.36 66.67 12.65 12.05 1.02 0.26 80 90 8.04 1.53 75.00 14.23 13.56 1.15 0.30 90 100 8.94 1.71 83.33 15.81 15.06 1.27 0.33 100 110 9.83 1.88 91.67 17.40 16.57 1.40 0.36 110 120 10.72 2.05 100.00 18.98 18.08 1.53 0.40 120 130 11.62 2.22 108.33 20.56 19.58 1.65 0.43 130 140 12.51 2.39 116.67 22.14 21.09 1.78 0.46 140 150 13.40 2.56 125.00 23.72 22.60 1.91 0.49 150 160 14.30 2.73 133.33 25.30 24.10 2.04 0.53 160 170 15.19 2.90 141.67 26.88 25.61 2.16 0.56 170 180 16.08 3.07 150.00 28.46 27.12 2.29 0.59 180 190 1.89 16.98 3.24 158.33 30.05 28.62 2.42 0.63 190 200 1.99 17.87 3.41 166.67 31.63 30.13 2.54 0.66 200 225 2.24 20.11 3.84 187.50 35.58 33.89 2.86 0.74 225 250 2.49 22.34 4.26 208.33 39.53 37.66 3.18 0.82 250 275 2.74 24.57 4.69 229.17 43.49 41.43 3.50 0.91 275 300 2.99 26.81 5.12 250.00 47.44 45.19 3.82 0.99 300 325 3.23 29.04 5.54 270.83 51.39 48.96 4.14 1.07 325 350 3.48 31.28 5.97 291.67 55.35 52.72 4.45 1.15 350 375 3.73 33.51 6.40 312.50 59.30 56.49 4.77 1.24 375 400 3.98 35.74 6.82 333.34 63.25 60.26 5.09 1.32 400 450 4.48 40.21 7.67 375.00 71.16 67.79 5.73 1.48 449 500 4.98 44.68 8.53 416.67 79.07 75.32 6.36 1.65 497 550 5.47 49.15 9.38 458.34 86.98 82.85 7.00 1.81 545 600 5.97 53.61 10.23 500.00 94.88 90.38 7.63 1.98 592 650 6.47 58.08 11.09 541.67 102.79 97.92 8.27 2.14 640 700 6.97 62.55 11.94 583.34 110.70 105.45 8.91 2.31 688 750 7.46 67.02 12.79 625.00 118.60 112.98 9.54 2.47 736 800 7.96 71.49 13.64 666.67 126.51 120.51 10.18 2.64 784 850 8.46 75.95 14.50 708.34 134.42 128.05 10.82 2.80 831 900 8.96 80.42 15.35 750.00 142.32 135.58 11.45 2.97 879 950 9.46 84.89 16.20 791.67 150.23 143.11 12.09 3.13 927 1000 9.95 89.36 17.06 833.34 158.14 150.64 12.72 3.30 975 Notes: 1 Transects 220, 230 (Main Channel), 400, 410, and 430. 2 Transects 120, 130, 140, 150, and 160. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 33 June 2014 4.2.10. Production of WUA for Grant Creek After the hydraulic models were calibrated, transect weighting and relative lengths to simulate a 1,000-foot reach were added for the rearing and spawning life stages. Flow apportioned to each of the transects was added, and final hydraulic model runs were made to produce input for the HABTAT habitat model. Output from the hydraulic models was then used to determine changes in the Grant Creek water depths, velocities, surface area, and fish habitat throughout a range of flows from 10 cfs to 1,000 cfs, depending on individual study site. In order to develop the most accurate models, KHL conducted three model runs for each transect and performed the following analysis: A one-velocity set model was used to model down from the middle flow measurement (approximately 180 to 200 cfs in the main channel as measured at the gage). Both one-velocity set and depth calibration models were run from the middle flow measurement (approximately 180 to 200 cfs as measured in the main channel at the gage) up to 1,000 cfs. The WUA results from the one-velocity set and depth calibration models were averaged to produce one WUA table for each species and life stage at each transect (from 180 to 200 cfs upward to 1,000 cfs, as measured at the gage). The results of these model runs were then combined to produce WUA over the entire range of flows of interest. [Note: the exception to these measured flows was in the side channels in Reach 3. At Transect 330, a calibration measurement was taken at a flow of 440 cfs, as measured at the gage]. 5 RESULTS 5.1. Grant Creek Aquatic Habitat Mapping Grant Creek consists of six reaches; however, the focus of the mapping was on Reaches 1 – 5, located below the upstream migrational barrier. GIS maps of aquatic habitats in Grant Creek are found in Figures 5.1-1 and 4.2-2. There are two series of maps: the first series (Figure 5.1-1) shows mesohabitats found in Reaches 1 – 5 (pools, glides, etc.); the second series (Figure 4.2-2) shows aquatic habitats (undercut banks, overhead cover, etc.) in the same reaches. Table 5.1-1 summarizes mesohabitats found in Grant Creek. Riffle habitats were predominant, accounting for 50 percent of all habitats. This was consistent throughout all reaches, with the exception of the secondary channel in Reach 3. Riffle habitats were followed by pools (19.3 percent) and cascades (15.3 percent); all of the cascades were found in the canyon (Reach 5). FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 34 June 2014 Table 5.1-2 shows habitat types (stream margin, overhead vegetation, undercut banks, and LWD) found in Grant Creek. LWD was sparse in the mainstem of Grant Creek. High flows in Grant Creek move LWD downstream and eventually into the Trail Lakes. In the side channels and distributaries, where flows and velocities are much less than in the main channel, LWD is relatively abundant. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 31212 47 June 2014 Table 5.1-1. Mesohabitats found in Grant Creek. Habitat Type Total Area (Sq. Ft) Reach 1 Distributary Reach 1 MainstemReach 2 Backwater Habitat Reach 2 MainstemReach 2 Secondary Channel Reach 3 Backwater Habitat Reach 3 MainstemReach 3 Primary Side ChannelReach 3 Secondary Channel Reach 4 MainstemReach 5 MainstemBackwater 8,534 0 0 4,837 0 0 3,697 0 0 0 0 0 Cascade 33,707 0 0 0 0 114 0 0 0 0 0 33,593 Glide 3,202 0 0 0 1,613 0 0 0 0 1,588 0 0 Pocket water 3,709 0 0 0 0 0 0 0 0 0 3,709 0 Pool 42,568 7,495 3,143 0 3,834 398 0 3,997 5,018 9,510 1,195 7,977 Rapid 511 0 0 0 0 0 0 0 511 0 0 0 Riffle 110,429 6,004 23,168 0 23,669 1,189 0 25,585 11,672 1,493 17,649 0 Run 576 0 0 0 0 0 0 0 0 576 0 0 Step Pool 16,858 0 0 0 0 0 0 0 0 0 0 16,858 Table 5.1-2. Aquatic habitats found in Grant Creek. Habitat Type Total Area (Sq. Ft) Reach 1 Distributary Reach 1 MainstemReach 2 Backwater Habitat Reach 2 MainstemReach 2 Secondary Channel Reach 3 Backwater Habitat Reach 3 MainstemReach 3 Primary Side Channel Reach 3 Secondary Channel Reach 4 MainstemReach 5 MainstemMargin 7,214 0 3,343 0 3,871 0 0 0 0 0 0 0 Overhead Vegetation (OHV) 10,096 302 0 0 0 0 0 0 ,2455 7,339 0 0 UCB 12,187 1,513 3,372 0 2,193 0 0 278 110 1,214 3,216 0 Large Woody Debris (LWD) 17,750 3,556 1,894 0 182 0 0 1,142 1,611 6,218 3,040 0 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 48 June 2014 5.2. Grant Creek Instream Flow Study 5.2.1. Weighted Usable Area Within the HABTAT program, output from the hydraulic modeling is combined with habitat suitability criteria for depth, velocity, and substrate/cover for the target species life stages. The output from this model is expressed as Flow (Q - cfs) versus WUA, which is an index of available habitat (in feet2 per 1,000 lineal feet of stream) for each species and life stage of concern. One-velocity set models and depth calibration models were developed to evaluate habitat at flows ranging from 10 – 1,000 cfs, as measured at the Grant Creek gage. Since one-velocity set models tend to predict velocities better when modeling lesser flows, a combination of one- velocity set and depth calibration models was used to evaluate flows > 200 cfs in the mainstem. Above the velocity calibration measurement, the WUA results of the two methods were averaged. The same methodology was used in side channels (Reaches 2/3), the distributary (T100 and T110), and in the mainstem where side channel habitat decreased flows in the mainstem (T320 and T330). Table 5.2-1 summarizes flows and models used to simulate flows in Grant Creek. Transects were run independently and were given the same weighting, since they were selected as being important rearing and spawning areas. WUA graphs and tables are found in Appendix 5 for the target species and life history stages for Grant Creek. Table 5.2-2 indicates which life history stages were modeled at each transect. Tables 5.2-3 to 5.2-23 and Figures 5.2-1 to 5.2-21 show Grant Creek Flow versus WUA graphs for the species and life history stages shown in Table 4.2-4. Appendix 5 includes the graphs and tables for the target species and life history stages for Grant Creek by transect. As stated in Section 4.9, the Reach 2 and 3 side channels are wetted at all flows, although low winter flows may result in freezing in the smaller side channels. The distributary in Reach 1 becomes wetted at a flow of approximately 190 cfs, while the overflow channel near the Reach 1/Reach 2 break becomes wetted at a flow of approximately 450 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 49 June 2014 Table 5.2-1. Range of flows and models used to simulate Grant Creek WUA. Flow Range (cfs) Transect 1-Velocity Model - Low 1-Velocity Set/Depth Calibration High 100 0.0 - 1.99 1.99 - 9.95 110 0.0 - 1.99 1.99 - 9.95 120 10 - 200 200 - 975 130 10 - 200 200 - 975 140 10 - 200 200 - 975 150 10 - 200 200 - 975 160 10 - 200 200 - 975 200 0.89 - 17.87 17.87 - 89.36 210 - - 220 10 - 200 200 - 1,000 230-Main 10 - 200 200 - 1,000 230-Side - - 300 0.17 - 3.41 3.41 - 17.06 310 8.33 - 166.67 166.67 320 1.58 - 31.63 31.63 - 158.14 330-Main 1.51 - 30.13 30.13 - 150.64 330-Sec 0.13 - 2.54 2.54 - 12.72 330-Ter 0.03 - 0.66 0.66 - 3.30 400 10 - 200 200 - 1,000 410 10 - 200 200 - 1,000 430 10 - 200 200 - 1,000 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 50 June 2014 Table 5.2-2. Life history stages modeled at each Grant Creek transect. Life History Stage Transect Spawning Rearing 100 110 120 130 140 150 160 200 2101/ 220 230-MC 230-SC1/ 300 310 320 330-MC 330-SC 330-TC 400 410 430 Note: 1 backwater FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 51 June 2014 Table 5.2-3. Salmonid Spawning WUA, Reach 1 distributary. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 1.89 22,534 0 5 240 153 4 1.99 22,832 0 7 267 171 7 2.34 23,670 0 13 375 240 15 2.49 24,091 1 19 431 273 19 2.74 24,638 1 35 542 333 26 2.99 24,863 2 52 661 403 38 3.23 25,070 3 69 771 474 53 3.48 25,223 5 86 875 553 76 3.73 25,328 6 111 996 638 103 3.98 26,572 7 141 1,129 726 131 4.48 27,880 10 232 1,433 918 197 4.98 28,558 11 338 1,736 1,122 284 5.47 28,902 16 461 2,011 1,323 386 5.97 29,813 24 616 2,304 1,538 503 6.47 30,676 34 794 2,585 1,759 630 6.97 33,195 46 973 2,813 1,976 762 7.46 33,889 53 1,151 3,012 2,176 889 7.96 34,378 61 1,322 3,191 2,385 1,026 8.46 34,852 68 1,485 3,361 2,599 1,167 8.96 35,301 76 1,635 3,513 2,814 1,303 9.46 36,740 83 1,765 3,647 3,025 1,436 Table 5.2-4. Fry rearing WUA, Reach 1 distributary. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 1.89 22,534 16,343 15,097 18,979 12,134 1.99 22,832 16,804 15,450 19,336 12,485 2.34 23,670 18,402 16,889 20,655 13,678 2.49 24,091 19,046 17,511 21,207 14,119 2.74 24,638 19,880 18,276 21,948 14,620 2.99 24,863 20,710 18,909 22,479 15,153 3.23 25,070 21,530 19,492 22,822 15,698 3.48 25,223 22,237 19,986 23,135 16,131 3.73 25,328 22,759 20,360 23,393 16,414 3.98 26,572 23,137 20,632 23,665 16,551 4.48 27,880 23,695 20,938 24,316 16,665 4.98 28,558 24,209 21,218 25,065 16,732 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 52 June 2014 Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 5.47 28,902 24,858 21,830 25,801 16,960 5.97 29,813 25,536 22,484 26,540 17,241 6.47 30,676 26,173 22,963 27,130 17,488 6.97 33,195 26,922 23,579 27,962 17,815 7.46 33,889 27,548 24,127 28,923 18,021 7.96 34,378 28,121 24,553 29,818 18,198 8.46 34,852 29,118 25,519 30,641 18,817 8.96 35,301 30,073 26,510 31,451 19,389 9.46 36,740 30,841 27,339 32,441 19,770 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 53 June 2014 Table 5.2-5. Adult and juvenile rearing WUA, Reach 1 distributary. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 1.89 22,534 17,881 13,111 7,914 1,558 332 1,597 1.99 22,832 18,438 13,632 8,333 1,681 396 1,811 2.34 23,670 20,209 14,987 9,757 2,127 644 2,563 2.49 24,091 20,881 15,443 10,309 2,330 784 2,889 2.74 24,638 21,800 16,159 11,152 2,674 1,028 3,409 2.99 24,863 22,568 17,176 11,972 3,013 1,273 3,942 3.23 25,070 23,233 18,241 12,610 3,342 1,509 4,466 3.48 25,223 23,766 19,131 13,211 3,693 1,752 5,035 3.73 25,328 24,178 19,702 13,808 4,063 2,001 5,603 3.98 26,572 24,579 20,177 14,404 4,434 2,261 6,165 4.48 27,880 25,055 21,078 15,614 5,170 2,801 7,321 4.98 28,558 25,564 21,928 16,702 5,899 3,344 8,543 5.47 28,902 26,628 22,436 17,644 6,624 3,897 9,741 5.97 29,813 27,472 22,916 18,582 7,361 4,503 10,952 6.47 30,676 28,192 23,675 19,493 8,089 5,113 12,173 6.97 33,195 28,846 24,544 20,242 8,811 5,723 13,310 7.46 33,889 29,537 25,223 20,949 9,526 6,332 14,359 7.96 34,378 30,049 25,919 21,649 10,260 6,958 15,395 8.46 34,852 31,595 26,630 22,338 10,994 7,580 16,330 8.96 35,301 32,859 27,181 23,002 11,737 8,203 17,203 9.46 36,740 33,597 27,629 23,694 12,481 8,833 17,950 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 54 June 2014 Table 5.2-6. Spawning WUA, Reach 1, mainstem. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 10 26,967 872 3,379 8,350 6,746 3,123 20 33,098 3,558 5,460 12,047 10,378 4,942 30 36,447 6,344 6,955 13,447 12,060 6,149 40 38,915 8,532 8,049 14,478 13,274 7,217 50 42,337 10,023 8,962 15,328 14,250 7,999 60 45,620 11,102 9,564 15,939 15,157 8,640 70 47,902 12,146 10,018 16,785 15,914 9,063 80 50,334 13,138 10,326 17,399 16,602 9,310 90 52,139 14,103 10,599 17,956 17,333 9,571 100 56,432 15,075 10,916 18,614 18,085 9,763 110 59,596 16,071 11,293 19,057 18,745 9,995 120 61,244 16,812 11,648 19,396 19,293 10,207 130 63,573 17,386 11,990 19,590 19,738 10,448 140 64,872 17,884 12,362 19,770 20,143 10,683 150 65,799 18,313 12,689 19,880 20,498 10,932 160 67,198 18,840 13,083 19,878 20,803 11,223 170 69,974 19,364 13,475 19,811 21,082 11,499 180 70,706 19,850 13,822 19,768 21,326 11,778 190 72,686 20,432 14,175 19,713 21,499 12,022 200 73,413 20,970 14,481 19,621 21,625 12,261 225 76,822 22,079 15,012 19,405 21,661 12,944 250 79,180 23,036 15,493 19,220 21,445 13,414 275 79,952 24,114 15,726 18,837 21,234 13,764 300 82,531 25,582 15,810 18,341 21,018 13,987 325 83,117 27,001 15,718 17,825 20,871 14,056 350 83,686 27,977 15,515 17,340 20,689 14,004 375 84,230 28,427 15,154 16,845 20,374 13,925 400 85,103 28,744 14,863 16,371 20,000 13,839 449 88,895 28,385 14,515 15,397 19,285 13,544 497 92,108 27,393 14,163 14,225 18,472 13,168 545 93,643 26,342 13,709 13,135 17,683 12,720 592 95,048 25,529 13,190 12,263 17,024 12,273 640 96,630 24,797 12,627 11,455 16,355 11,878 688 99,448 24,088 12,094 10,773 15,712 11,518 736 101,217 23,337 11,562 10,231 15,040 11,143 784 102,415 22,595 11,052 9,780 14,389 10,766 831 103,503 21,926 10,586 9,413 13,805 10,455 879 105,212 21,333 10,130 9,095 13,236 10,144 927 106,171 20,705 9,729 8,841 12,761 9,841 975 107,507 20,081 9,376 8,660 12,366 9,602 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 55 June 2014 Table 5.2-7. Fry rearing WUA, Reach 1 mainstem. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 10 26,967 18,102 12,479 19,131 9,386 20 33,098 17,887 11,044 19,882 9,359 30 36,447 18,464 10,797 19,779 9,591 40 38,915 18,953 10,581 19,567 9,371 50 42,337 18,841 10,049 19,342 9,142 60 45,620 18,935 9,746 19,419 9,110 70 47,902 18,979 9,273 19,368 8,783 80 50,334 18,746 8,632 19,228 8,541 90 52,139 18,549 8,168 19,102 8,533 100 56,432 18,393 7,978 19,101 8,528 110 59,596 18,249 8,158 19,424 8,579 120 61,244 18,415 8,369 19,806 8,526 130 63,573 19,054 8,933 20,083 8,749 140 64,872 19,848 9,528 20,528 9,220 150 65,799 20,835 10,231 20,782 9,849 160 67,198 21,574 10,622 20,680 10,337 170 69,974 22,273 10,686 20,494 10,716 180 70,706 22,520 10,604 20,603 10,894 190 72,686 22,675 10,978 20,912 11,206 200 73,413 22,884 11,500 21,357 11,626 225 76,822 23,742 12,439 21,907 12,664 250 79,180 24,585 13,157 22,765 13,074 275 79,952 25,437 13,608 22,988 13,288 300 82,531 26,239 14,242 23,045 13,572 325 83,117 26,346 14,356 23,255 13,398 350 83,686 26,776 14,853 23,319 13,676 375 84,230 27,300 15,529 23,299 13,995 400 85,103 27,753 15,939 23,038 14,408 449 88,895 27,920 16,028 23,811 14,502 497 92,108 28,918 16,667 25,133 14,811 545 93,643 29,941 17,384 25,805 15,438 592 95,048 30,887 18,177 26,101 15,975 640 96,630 31,640 18,677 26,225 16,106 688 99,448 31,909 18,627 26,582 15,733 736 101,217 32,301 18,843 27,391 15,690 784 102,415 33,239 19,841 28,329 16,031 831 103,503 34,286 20,594 28,715 16,657 879 105,212 34,976 20,837 28,709 17,112 927 106,171 35,261 21,023 28,978 17,162 975 107,507 35,477 21,329 29,481 17,160 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 56 June 2014 Table 5.2-8. Adult and juvenile rearing WUA, Reach 1 mainstem. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 10 26,967 22,255 20,247 15,763 7,743 5,517 9,063 20 33,098 24,342 22,088 16,888 10,185 7,415 10,434 30 36,447 25,542 24,363 17,997 12,004 8,889 10,639 40 38,915 25,854 25,018 18,077 13,374 10,095 10,534 50 42,337 25,533 25,550 17,904 14,248 11,046 10,144 60 45,620 25,431 26,784 17,436 14,992 11,825 9,882 70 47,902 25,379 27,100 17,202 15,708 12,478 9,659 80 50,334 25,527 27,278 17,189 16,359 13,017 9,613 90 52,139 25,719 27,421 17,401 16,857 13,408 9,640 100 56,432 25,478 27,616 17,280 17,200 13,673 9,691 110 59,596 25,571 27,939 17,271 17,394 13,832 9,726 120 61,244 25,584 28,027 17,396 17,559 13,952 9,781 130 63,573 26,702 27,948 17,229 17,720 14,045 9,797 140 64,872 27,256 27,850 16,955 17,757 14,055 9,844 150 65,799 28,032 28,147 16,882 17,737 14,026 9,828 160 67,198 28,388 28,826 17,190 17,635 13,909 9,735 170 69,974 28,040 30,371 17,492 17,526 13,787 9,634 180 70,706 27,485 30,925 17,619 17,513 13,705 9,567 190 72,686 27,608 30,654 17,659 17,556 13,656 9,505 200 73,413 27,926 30,196 17,688 17,615 13,611 9,464 225 76,822 27,872 30,259 17,900 17,789 13,594 9,709 250 79,180 28,642 29,505 18,088 18,079 13,773 10,032 275 79,952 29,392 30,645 18,621 18,470 14,146 10,429 300 82,531 29,829 32,194 19,208 18,942 14,629 10,820 325 83,117 29,399 31,953 19,572 19,559 15,102 11,232 350 83,686 29,878 31,779 19,893 20,108 15,575 11,807 375 84,230 29,934 31,931 20,245 20,564 16,036 12,447 400 85,103 29,633 32,482 20,535 20,980 16,549 12,974 449 88,895 28,937 32,147 20,531 21,771 17,477 13,775 497 92,108 30,891 32,210 20,961 22,470 18,152 14,411 545 93,643 31,891 33,537 22,209 23,241 18,819 15,001 592 95,048 32,622 34,279 23,412 23,980 19,464 15,639 640 96,630 32,649 35,395 24,200 24,750 20,245 16,216 688 99,448 32,377 35,494 24,826 25,550 21,066 16,818 736 101,217 32,689 35,811 25,615 26,250 21,841 17,467 784 102,415 34,229 35,752 26,457 26,949 22,570 18,192 831 103,503 35,070 36,393 26,997 27,547 23,187 18,924 879 105,212 35,166 37,667 27,587 28,078 23,770 19,675 927 106,171 35,073 37,998 27,894 28,647 24,367 20,377 975 107,507 35,237 37,601 28,087 29,189 24,918 21,011 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 57 June 2014 Table 5.2-9. Spawning WUA, Reach 2 mainstem. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 10 31,269 236 1,777 7,073 5,290 1,642 20 35,944 2,018 2,924 10,244 8,147 2,645 30 39,224 4,515 3,928 11,888 9,810 3,465 40 41,713 6,728 4,786 12,883 11,160 4,062 50 42,780 8,097 5,355 13,047 12,015 4,549 60 43,867 9,385 5,545 12,789 12,449 4,880 70 44,472 10,434 5,608 12,381 12,633 5,053 80 45,042 11,408 5,758 12,118 12,717 5,119 90 45,761 12,109 5,796 11,983 12,681 5,064 100 45,828 12,687 5,770 11,590 12,594 4,933 110 46,574 13,085 5,746 11,124 12,472 4,811 120 47,242 13,195 5,676 10,575 12,286 4,759 130 47,876 13,171 5,615 10,130 12,092 4,708 140 50,679 13,176 5,581 9,785 11,885 4,655 150 51,632 13,177 5,504 9,438 11,640 4,611 160 53,836 13,170 5,347 9,046 11,219 4,526 170 54,513 13,161 5,209 8,703 10,796 4,448 180 55,164 13,127 5,123 8,363 10,424 4,398 190 55,791 13,089 5,047 8,112 10,082 4,350 200 59,112 13,046 4,959 7,873 9,802 4,300 225 59,322 12,897 4,796 7,310 9,353 4,162 250 59,404 12,717 4,558 7,339 9,048 4,040 275 59,481 12,622 4,331 7,526 8,994 4,055 300 59,554 12,543 4,100 7,764 8,889 4,202 325 59,623 12,162 4,242 8,331 8,907 4,364 350 59,688 11,710 4,630 8,922 8,976 4,618 375 59,751 11,342 5,084 9,181 8,934 4,954 400 59,811 10,900 5,630 9,275 8,846 5,271 450 59,925 10,399 6,638 9,137 8,719 5,764 500 60,021 10,586 7,235 8,554 8,790 6,168 550 60,109 11,238 7,407 7,987 8,913 6,502 600 60,192 11,728 7,195 7,394 8,755 6,623 650 60,270 11,805 6,877 6,746 8,318 6,520 700 60,345 11,629 6,447 6,149 7,697 6,308 750 60,416 10,973 6,025 5,599 7,035 5,953 800 60,485 10,339 5,600 5,177 6,427 5,584 850 60,602 9,740 5,171 4,785 5,820 5,191 900 60,947 9,251 4,748 4,433 5,253 4,845 950 61,280 8,806 4,313 4,079 4,695 4,498 1000 61,602 8,221 3,980 3,730 4,277 4,163 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 58 June 2014 Table 5.2-10. Fry rearing WUA, Reach 2 mainstem. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 10 31,269 24,484 17,008 25,081 12,448 20 35,944 21,904 12,212 22,542 10,279 30 39,224 19,647 9,281 20,897 9,021 40 41,713 18,503 8,125 20,274 8,840 50 42,780 17,904 8,141 19,172 8,746 60 43,867 17,343 8,198 18,113 8,482 70 44,472 17,321 8,259 17,079 8,500 80 45,042 17,179 8,372 16,362 8,356 90 45,761 16,837 8,091 15,516 7,996 100 45,828 15,673 7,069 13,822 7,452 110 46,574 15,078 6,781 13,169 7,093 120 47,242 14,397 6,399 12,664 6,652 130 47,876 13,904 6,218 12,310 6,394 140 50,679 13,635 6,176 12,268 6,223 150 51,632 13,409 6,042 12,528 6,087 160 53,836 13,175 6,078 13,129 5,998 170 54,513 13,533 6,771 13,850 6,262 180 55,164 13,971 7,531 14,554 6,462 190 55,791 14,685 8,340 15,133 6,842 200 59,112 15,181 8,671 15,476 7,000 225 59,322 16,823 9,436 16,726 7,710 250 59,404 18,729 11,185 17,467 8,315 275 59,481 19,851 11,163 16,729 8,070 300 59,554 20,304 10,182 15,607 7,761 325 59,623 19,273 8,434 14,550 7,125 350 59,688 17,989 7,441 13,621 6,627 375 59,751 16,816 6,775 12,783 6,172 400 59,811 16,192 6,148 11,976 5,768 450 59,925 14,987 5,196 10,575 5,161 500 60,021 14,175 4,327 9,318 4,591 550 60,109 13,244 3,539 8,165 4,074 600 60,192 12,325 2,920 7,157 3,688 650 60,270 11,415 2,466 6,225 3,344 700 60,345 10,622 2,117 5,481 3,036 750 60,416 9,947 1,803 4,817 2,758 800 60,485 9,419 1,615 4,310 2,491 850 60,602 8,954 1,460 3,904 2,213 900 60,947 8,544 1,266 3,562 1,920 950 61,280 8,215 1,158 3,305 1,693 1000 61,602 7,999 1,103 3,081 1,514 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 59 June 2014 Table 5.2-11. Adult and juvenile rearing WUA, Reach 2 mainstem. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 10 31,269 29,262 27,497 24,362 9,099 5,457 12,123 20 35,944 29,786 29,517 25,358 12,272 8,137 14,734 30 39,224 28,332 28,670 22,919 14,655 10,187 14,324 40 41,713 27,726 28,334 20,783 16,432 11,846 13,142 50 42,780 26,767 28,652 18,644 17,567 13,110 12,107 60 43,867 25,361 28,121 17,675 18,050 13,801 10,975 70 44,472 24,498 27,560 16,567 17,981 13,972 9,832 80 45,042 23,538 26,597 15,711 17,881 14,020 8,977 90 45,761 22,382 25,667 15,052 17,639 13,932 8,307 100 45,828 20,024 24,475 14,228 17,254 13,720 7,719 110 46,574 18,846 23,536 13,530 16,887 13,477 7,218 120 47,242 17,609 22,239 12,845 16,396 13,080 6,839 130 47,876 16,810 21,160 12,421 15,918 12,710 6,488 140 50,679 16,168 20,184 12,026 15,402 12,306 6,251 150 51,632 15,563 19,482 11,618 14,866 11,837 6,063 160 53,836 15,122 18,690 11,197 14,246 11,283 5,897 170 54,513 15,883 18,170 10,829 13,740 10,854 5,744 180 55,164 16,551 17,550 10,629 13,366 10,548 5,625 190 55,791 17,480 17,153 10,561 12,883 10,143 5,550 200 59,112 17,806 17,335 10,611 12,424 9,746 5,513 225 59,322 18,690 19,110 10,953 11,694 9,137 5,499 250 59,404 20,914 19,227 11,492 10,844 8,338 5,548 275 59,481 21,286 20,826 12,511 10,048 7,485 5,705 300 59,554 20,474 22,524 13,556 9,475 6,818 5,947 325 59,623 19,466 21,593 14,296 9,179 6,342 6,203 350 59,688 18,591 20,730 14,735 9,059 6,081 6,547 375 59,751 17,847 19,941 14,960 9,009 5,910 7,009 400 59,811 17,120 19,246 15,103 9,066 5,948 7,427 450 59,925 15,936 17,936 15,003 9,250 6,290 7,980 500 60,021 14,689 16,617 13,690 9,497 6,701 8,236 550 60,109 13,332 15,256 12,386 9,613 7,012 8,146 600 60,192 11,848 13,902 10,640 9,621 7,226 7,869 650 60,270 10,402 12,601 9,458 9,511 7,315 7,418 700 60,345 9,165 11,357 8,334 9,279 7,281 6,873 750 60,416 7,998 10,242 7,237 9,007 7,212 6,230 800 60,485 7,149 9,242 6,338 8,705 7,084 5,551 850 60,602 6,427 8,383 5,524 8,441 6,975 4,988 900 60,947 5,660 7,605 4,905 8,128 6,806 4,427 950 61,280 5,069 6,875 4,428 7,713 6,521 3,910 1000 61,602 4,714 6,198 3,977 7,278 6,218 3,449 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 60 June 2014 Table 5.2-12. Spawning WUA, Reach 3 mainstem. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 8.3 32,346 151 2,140 7,544 6,590 2,043 16.7 42,740 2,809 3,446 10,756 9,846 3,140 25.0 51,753 6,013 4,453 11,949 11,625 4,051 33.3 53,791 8,267 5,033 12,995 12,785 4,745 41.7 54,616 9,238 5,471 13,906 13,676 5,319 50.0 54,999 9,870 5,850 14,728 14,357 5,715 58.3 55,337 10,345 6,186 15,286 14,889 5,861 66.7 55,708 10,777 6,467 15,659 15,412 5,948 75.0 56,061 11,103 6,682 15,926 15,916 6,064 83.3 56,385 11,707 6,883 15,835 16,190 6,079 91.7 56,741 12,294 6,999 15,560 16,287 6,065 100.0 57,100 12,786 7,061 15,003 16,299 6,085 108.3 57,438 13,257 7,079 14,434 16,242 6,103 116.7 57,757 13,626 7,092 13,818 16,110 6,103 125.0 58,209 13,952 7,118 13,210 15,958 6,091 133.3 58,744 14,274 7,089 12,668 15,652 6,073 141.7 59,221 14,538 7,034 12,099 15,232 6,067 150.0 59,471 14,793 6,988 11,577 14,828 6,067 158.3 59,711 15,045 6,913 11,126 14,404 6,070 166.7 59,942 15,290 6,815 10,740 13,951 6,067 187.5 60,470 15,860 6,689 10,071 13,073 6,089 208.3 60,874 15,998 6,621 9,918 12,459 6,113 229.2 61,188 15,810 6,566 9,920 12,116 6,096 250.0 61,481 15,553 6,495 10,000 11,847 6,114 270.8 61,756 15,193 6,432 10,163 11,686 6,110 291.7 62,016 14,729 6,396 10,250 11,738 6,060 312.5 62,263 14,255 6,383 10,306 11,789 5,995 333.3 62,423 13,826 6,355 10,309 11,811 5,955 375.0 62,561 13,226 6,279 10,156 11,849 5,963 416.7 62,687 13,050 6,357 10,036 11,729 5,957 458.3 62,805 13,149 6,490 9,621 11,511 5,889 500.0 62,915 13,546 6,507 9,183 10,983 5,837 541.7 63,018 14,110 6,424 8,595 10,419 5,764 583.3 63,116 14,586 6,181 7,923 9,830 5,742 625.0 63,208 15,009 5,930 7,251 9,271 5,712 666.7 63,296 15,222 5,713 6,629 8,823 5,614 708.3 63,380 14,884 5,471 6,068 8,315 5,449 750.0 63,461 14,517 5,175 5,539 7,739 5,268 791.7 65,946 14,064 4,856 5,011 7,141 5,051 833.3 67,051 13,531 4,516 4,492 6,544 4,806 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 61 June 2014 Table 5.2-13. Fry rearing WUA, Reach 3 mainstem. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 8.3 32,346 29,903 24,015 28,929 18,070 16.7 42,740 27,783 19,495 31,277 16,562 25.0 51,753 32,397 23,690 37,584 21,026 33.3 53,791 37,491 28,419 40,047 25,608 41.7 54,616 39,662 29,949 39,638 28,192 50.0 54,999 39,510 29,277 38,241 28,807 58.3 55,337 38,353 28,323 36,938 28,327 66.7 55,708 37,058 27,333 35,748 27,686 75.0 56,061 36,010 26,648 34,864 26,992 83.3 56,385 35,130 26,300 34,113 26,331 91.7 56,741 34,238 26,009 33,206 25,691 100.0 57,100 33,467 25,731 32,454 25,077 108.3 57,438 33,022 25,576 31,901 24,397 116.7 57,757 32,807 25,451 31,465 23,987 125.0 58,209 32,662 25,266 31,075 23,625 133.3 58,744 32,519 25,010 30,755 23,370 141.7 59,221 32,490 24,939 30,625 23,268 150.0 59,471 32,419 24,906 30,551 23,106 158.3 59,711 32,313 24,863 30,541 22,970 166.7 59,942 32,271 24,705 30,441 22,781 187.5 60,470 32,325 24,402 29,809 22,288 208.3 60,874 31,741 23,640 28,949 21,222 229.2 61,188 30,960 22,764 28,099 20,267 250.0 61,481 30,149 21,962 27,459 19,498 270.8 61,756 29,567 21,285 26,810 18,785 291.7 62,016 29,133 20,440 25,930 17,973 312.5 62,263 28,412 19,381 25,086 17,179 333.3 62,423 27,590 18,427 24,343 16,544 375.0 62,561 26,275 17,093 22,990 15,545 416.7 62,687 25,178 15,794 21,365 14,326 458.3 62,805 23,923 14,483 19,862 13,193 500.0 62,915 22,575 13,320 18,473 12,105 541.7 63,018 21,392 12,292 17,186 11,080 583.3 63,116 20,290 11,421 15,962 10,154 625.0 63,208 19,388 10,606 14,783 9,293 666.7 63,296 18,495 9,837 13,675 8,489 708.3 63,380 17,617 9,113 12,636 7,761 750.0 63,461 16,802 8,446 11,668 7,096 791.7 65,946 16,033 7,784 11,085 6,525 833.3 67,051 15,306 7,202 10,921 6,003 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 62 June 2014 Table 5.2-14. Adult and juvenile rearing WUA, Reach 3 mainstem. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 8.3 32,346 31,450 28,955 23,971 9,234 5,651 13,061 16.7 42,740 34,698 30,328 28,111 14,041 9,778 20,164 25.0 51,753 42,000 34,550 28,848 17,586 12,986 21,726 33.3 53,791 47,541 38,414 28,524 20,444 15,469 21,837 41.7 54,616 47,877 41,083 27,222 22,991 17,630 21,626 50.0 54,999 46,658 41,986 26,976 25,135 19,593 21,289 58.3 55,337 44,853 41,567 26,666 26,736 21,284 21,205 66.7 55,708 43,208 41,281 26,091 28,008 22,832 21,042 75.0 56,061 42,041 40,631 25,541 28,966 24,061 21,075 83.3 56,385 40,962 39,686 25,369 29,504 24,837 21,234 91.7 56,741 39,725 38,939 25,206 29,740 25,210 21,445 100.0 57,100 38,428 38,245 24,800 29,590 25,158 21,704 108.3 57,438 37,718 37,267 24,535 29,210 24,875 22,031 116.7 57,757 37,115 36,286 24,419 28,658 24,447 22,394 125.0 58,209 36,489 35,523 24,370 28,153 24,072 22,705 133.3 58,744 35,996 34,997 24,409 27,663 23,691 22,952 141.7 59,221 35,733 34,467 24,227 27,120 23,277 23,191 150.0 59,471 35,630 33,725 23,932 26,715 22,979 23,393 158.3 59,711 35,283 33,039 23,691 26,199 22,541 23,550 166.7 59,942 34,978 32,723 23,548 25,742 22,183 23,663 187.5 60,470 34,765 32,932 23,482 25,767 22,337 23,562 208.3 60,874 33,703 32,841 23,485 25,804 22,450 23,027 229.2 61,188 32,593 32,547 23,206 26,065 22,658 22,302 250.0 61,481 32,021 31,751 23,072 26,377 22,784 21,574 270.8 61,756 31,400 31,112 23,073 26,648 22,950 21,048 291.7 62,016 30,646 31,096 23,141 27,007 23,269 20,495 312.5 62,263 29,686 30,678 23,204 27,252 23,555 19,859 333.3 62,423 28,925 29,963 23,101 27,401 23,813 19,144 375.0 62,561 27,843 28,692 22,507 27,118 23,963 17,875 416.7 62,687 26,500 27,786 22,075 26,191 23,719 16,610 458.3 62,805 25,039 26,597 21,327 25,305 23,408 15,275 500.0 62,915 23,599 25,013 20,452 23,998 22,464 13,960 541.7 63,018 22,180 23,373 19,466 22,471 21,088 12,676 583.3 63,116 20,746 21,929 18,236 21,225 19,922 11,439 625.0 63,208 19,330 20,595 16,969 20,149 18,937 10,263 666.7 63,296 17,939 19,345 15,917 19,182 18,064 9,150 708.3 63,380 16,580 18,060 14,781 18,102 17,084 8,082 750.0 63,461 15,369 16,819 13,659 16,966 16,036 7,096 791.7 65,946 14,198 15,606 12,649 15,807 14,950 6,193 833.3 67,051 13,045 14,424 11,619 14,688 13,912 5,348 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 63 June 2014 Table 5.2-15. Spawning WUA, Reach 3 side channels. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 2 32,404 0 145 1,049 657 147 3 35,974 22 424 2,503 1,568 345 5 36,746 146 765 3,167 2,113 608 7 37,374 435 1,184 3,825 2,622 903 8 38,000 910 1,590 4,357 3,090 1,223 10 38,499 1,310 2,006 4,884 3,524 1,639 12 38,832 1,743 2,436 5,359 3,939 2,057 13 39,610 2,172 2,965 5,858 4,343 2,448 15 40,349 2,442 3,400 6,240 4,700 2,803 17 40,848 2,749 3,817 6,372 5,005 3,153 18 41,832 3,055 4,191 6,502 5,294 3,472 20 42,914 3,364 4,469 6,637 5,570 3,761 22 43,608 3,646 4,705 6,743 5,802 3,977 23 44,579 3,935 4,863 6,843 6,026 4,179 25 45,959 4,234 4,959 6,918 6,248 4,373 27 47,801 4,480 5,036 6,999 6,453 4,545 28 48,964 4,707 5,103 7,068 6,642 4,683 30 50,155 4,932 5,155 7,127 6,826 4,802 32 50,737 5,087 5,209 7,192 6,990 4,877 33 50,652 5,152 5,256 7,244 7,085 4,880 37 51,649 5,312 5,391 7,346 7,299 4,905 42 53,245 5,483 5,519 7,409 7,492 4,945 46 53,965 5,577 5,652 7,435 7,670 4,970 50 54,889 5,674 5,782 7,381 7,769 4,996 54 55,932 5,778 5,914 7,322 7,867 5,023 58 56,809 5,880 6,022 7,273 7,939 5,055 63 57,610 6,020 6,086 7,181 7,944 5,098 67 58,643 6,173 6,126 7,071 7,944 5,147 75 60,644 6,491 6,152 6,876 7,945 5,243 83 62,013 6,794 6,161 6,830 8,020 5,341 92 63,301 7,060 6,132 6,821 8,052 5,480 100 66,612 7,259 6,195 6,876 8,065 5,607 108 68,209 7,384 6,283 6,932 8,038 5,722 117 69,816 7,486 6,367 6,892 8,001 5,840 125 70,918 7,589 6,404 6,875 7,962 5,938 133 72,029 7,684 6,389 6,833 7,912 6,032 142 72,825 7,777 6,380 6,794 7,832 6,103 150 73,607 7,851 6,386 6,778 7,721 6,150 158 74,279 7,930 6,408 6,782 7,627 6,204 167 74,940 8,022 6,433 6,787 7,550 6,268 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 64 June 2014 Table 5.2-16. Fry rearing WUA, Reach 3 side channels. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 2 32,404 22,323 22,277 26,991 18,292 3 35,974 25,215 22,852 30,218 19,446 5 36,746 27,267 24,050 31,763 21,018 7 37,374 29,224 25,275 32,287 22,493 8 38,000 30,415 25,671 31,902 23,178 10 38,499 30,862 25,498 31,434 23,315 12 38,832 30,766 25,155 31,050 23,086 13 39,610 30,535 24,685 30,709 22,802 15 40,349 30,203 24,143 30,354 22,357 17 40,848 29,861 23,773 30,169 22,022 18 41,832 29,597 23,642 30,137 21,747 20 42,914 29,452 23,682 30,285 21,470 22 43,608 29,352 23,741 30,461 21,246 23 44,579 29,331 23,861 30,730 21,109 25 45,959 29,478 24,017 31,090 21,088 27 47,801 29,673 24,218 31,644 21,225 28 48,964 30,074 24,650 32,342 21,567 30 50,155 30,551 25,077 33,151 21,955 32 50,737 31,169 25,546 33,924 22,485 33 50,652 31,654 25,860 34,322 22,900 37 51,649 33,499 27,422 35,539 24,613 42 53,245 34,885 28,475 36,432 25,997 46 53,965 35,822 28,986 37,076 26,914 50 54,889 36,607 29,534 37,645 27,617 54 55,932 37,383 30,032 38,104 28,225 58 56,809 38,124 30,490 38,521 28,835 63 57,610 38,662 30,714 38,790 29,231 67 58,643 39,018 30,844 39,032 29,373 75 60,644 39,565 30,889 39,536 29,487 83 62,013 39,760 30,766 39,885 29,298 92 63,301 39,881 30,823 40,280 28,996 100 66,612 40,211 31,035 41,030 28,819 108 68,209 41,030 31,401 42,020 29,003 117 69,816 41,875 31,972 43,118 29,211 125 70,918 43,232 32,856 43,864 29,819 133 72,029 44,353 33,367 44,203 30,269 142 72,825 45,195 33,969 44,515 30,553 150 73,607 45,822 33,892 44,250 30,782 158 74,279 45,958 33,364 43,959 30,476 167 74,940 45,714 32,547 43,485 29,934 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 65 June 2014 Table 5.2-17. Adult and juvenile rearing WUA, Reach 3 side channels. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 2 32,404 24,355 15,607 7,862 1,834 683 2,237 3 35,974 29,181 19,229 11,332 2,804 1,129 3,673 5 36,746 32,701 22,900 14,102 3,666 1,625 4,870 7 37,374 34,866 25,736 16,597 4,480 2,093 5,849 8 38,000 35,912 28,202 18,334 5,298 2,566 6,670 10 38,499 35,795 29,682 19,282 6,074 3,029 7,475 12 38,832 35,610 30,199 20,054 6,841 3,523 8,170 13 39,610 35,078 30,352 20,536 7,574 4,065 8,828 15 40,349 34,495 30,539 20,864 8,281 4,591 9,444 17 40,848 33,987 30,666 20,965 8,945 5,106 9,984 18 41,832 33,959 30,675 20,948 9,596 5,625 10,504 20 42,914 33,938 30,560 20,924 10,228 6,140 11,043 22 43,608 33,848 30,509 20,951 10,795 6,632 11,541 23 44,579 33,847 30,561 21,005 11,341 7,121 12,015 25 45,959 33,955 30,695 21,111 11,846 7,588 12,462 27 47,801 34,144 30,625 21,226 12,338 8,042 12,877 28 48,964 34,830 30,571 21,287 12,783 8,461 13,296 30 50,155 35,338 30,574 21,355 13,219 8,869 13,713 32 50,737 35,978 30,789 21,429 13,631 9,257 14,095 33 50,652 36,303 31,047 21,583 14,028 9,631 14,476 37 51,649 38,567 32,172 22,176 14,995 10,530 15,392 42 53,245 39,997 33,173 22,918 15,864 11,360 16,235 46 53,965 40,783 34,151 23,583 16,666 12,118 17,034 50 54,889 41,863 35,035 24,237 17,451 12,870 17,860 54 55,932 42,780 36,157 25,018 18,180 13,601 18,611 58 56,809 43,247 37,372 25,764 18,939 14,335 19,372 63 57,610 43,825 38,544 26,538 19,718 15,087 20,098 67 58,643 44,373 39,265 27,335 20,516 15,826 20,828 75 60,644 45,008 40,662 29,001 22,087 17,220 22,403 83 62,013 45,615 41,562 30,667 23,596 18,633 23,900 92 63,301 46,227 42,267 31,945 25,103 20,091 25,435 100 66,612 47,115 42,839 33,153 26,502 21,568 26,917 108 68,209 48,170 44,016 34,122 27,884 22,972 28,142 117 69,816 49,601 44,867 35,043 29,235 24,286 29,104 125 70,918 51,261 46,516 36,011 30,606 25,521 29,966 133 72,029 52,297 48,352 37,072 32,003 26,817 30,770 142 72,825 53,419 49,259 38,047 33,382 28,084 31,367 150 73,607 53,886 50,591 38,975 34,784 29,417 31,965 158 74,279 53,915 51,312 39,799 36,116 30,783 32,531 167 74,940 53,733 51,945 40,625 37,452 32,214 33,044 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 66 June 2014 Table 5.2-18. Spawning WUA, Reach 3 combined. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 10 64,750 151 2,284 8,593 7,247 2,190 20 78,714 2,831 3,870 13,259 11,415 3,485 30 88,499 6,159 5,218 15,116 13,738 4,659 40 91,165 8,702 6,217 16,820 15,407 5,649 50 92,616 10,147 7,060 18,263 16,765 6,543 60 93,498 11,181 7,856 19,612 17,880 7,354 70 94,169 12,088 8,622 20,644 18,829 7,918 80 95,319 12,949 9,431 21,517 19,755 8,396 90 96,410 13,545 10,082 22,165 20,616 8,867 100 97,233 14,456 10,700 22,207 21,195 9,232 110 98,573 15,349 11,190 22,063 21,580 9,537 120 100,014 16,149 11,529 21,640 21,869 9,845 130 101,045 16,903 11,784 21,177 22,044 10,079 140 102,336 17,561 11,954 20,661 22,136 10,282 150 104,168 18,187 12,077 20,129 22,206 10,464 160 106,545 18,754 12,125 19,667 22,105 10,617 170 108,184 19,245 12,136 19,167 21,874 10,751 180 109,626 19,725 12,143 18,704 21,654 10,869 190 110,447 20,132 12,122 18,318 21,394 10,948 200 110,594 20,442 12,071 17,985 21,036 10,947 225 112,119 21,107 11,997 17,242 20,233 10,923 250 114,119 21,337 11,966 16,990 19,636 10,928 275 115,152 21,137 11,950 16,901 19,280 10,877 300 116,369 20,857 11,918 16,865 18,925 10,871 325 117,688 20,456 11,898 16,956 18,689 10,851 350 118,825 19,913 11,891 17,030 18,678 10,797 375 119,873 19,374 11,878 17,076 18,637 10,749 400 121,066 18,871 11,853 17,097 18,618 10,743 450 123,205 18,059 11,776 17,083 18,688 10,842 500 124,701 17,640 11,870 17,311 18,809 10,946 550 126,106 17,439 12,055 17,295 18,950 11,024 600 129,527 17,568 12,305 17,202 18,892 11,123 650 131,227 17,893 12,544 16,941 18,799 11,228 700 132,932 18,226 12,659 16,495 18,664 11,424 750 134,126 18,640 12,747 16,089 18,555 11,610 800 135,325 18,998 12,809 15,673 18,493 11,770 850 136,205 18,906 12,786 15,378 18,221 11,844 900 137,068 18,864 12,731 15,111 17,873 11,896 950 140,225 18,829 12,650 14,845 17,519 11,927 1,000 141,991 18,804 12,544 14,585 17,190 11,965 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 67 June 2014 Table 5.2-19. Fry rearing WUA, Reach 3 combined. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 10 64,750 52,226 46,291 55,920 36,361 20 78,714 52,997 42,348 61,496 36,008 30 88,499 59,664 47,740 69,348 42,044 40 91,165 66,715 53,693 72,335 48,101 50 92,616 70,077 55,620 71,540 51,370 60 93,498 70,372 54,775 69,675 52,122 70 94,169 69,119 53,478 67,988 51,412 80 95,319 67,593 52,018 66,457 50,488 90 96,410 66,214 50,791 65,218 49,349 100 97,233 64,991 50,073 64,282 48,353 110 98,573 63,835 49,651 63,342 47,438 120 100,014 62,919 49,413 62,739 46,547 130 101,045 62,374 49,317 62,362 45,643 140 102,336 62,138 49,312 62,195 45,097 150 104,168 62,140 49,283 62,165 44,713 160 106,545 62,192 49,227 62,399 44,595 170 108,184 62,564 49,588 62,967 44,835 180 109,626 62,969 49,983 63,702 45,061 190 110,447 63,482 50,409 64,465 45,455 200 110,594 63,925 50,565 64,763 45,680 225 112,119 66,090 52,168 65,613 47,156 250 114,119 67,208 52,816 65,959 47,738 275 115,152 67,710 52,794 66,092 47,958 300 116,369 68,027 52,868 66,379 48,157 325 117,688 68,566 53,017 66,559 48,335 350 118,825 69,246 52,929 66,469 48,410 375 119,873 69,410 52,356 66,270 48,283 400 121,066 69,274 51,776 66,138 48,049 450 123,205 69,116 50,981 66,069 47,660 500 124,701 68,873 50,083 65,566 46,653 550 126,106 68,353 49,263 65,160 45,600 600 129,527 67,872 48,721 65,152 44,692 650 131,227 68,046 48,444 65,438 44,191 700 132,932 68,302 48,527 65,857 43,791 750 134,126 69,294 48,952 65,930 43,817 800 135,325 70,016 49,023 65,639 43,693 850 136,205 70,429 49,185 65,348 43,421 900 137,068 70,635 48,709 64,528 43,129 950 140,225 70,363 47,729 64,037 42,428 1,000 141,991 69,729 46,550 63,809 41,537 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 68 June 2014 Table 5.2-20. Adult and juvenile rearing WUA, Reach 3 combined. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 10 64,750 55,805 44,562 31,833 11,068 6,334 15,298 20 78,714 63,879 49,557 39,443 16,845 10,908 23,837 30 88,499 74,701 57,450 42,950 21,253 14,611 26,596 40 91,165 82,407 64,151 45,121 24,924 17,562 27,685 50 92,616 83,789 69,285 45,556 28,289 20,196 28,296 60 93,498 82,453 71,668 46,258 31,209 22,621 28,764 70 94,169 80,463 71,767 46,720 33,577 24,807 29,375 80 95,319 78,286 71,633 46,627 35,582 26,897 29,870 90 96,410 76,537 71,169 46,404 37,247 28,653 30,520 100 97,233 74,949 70,352 46,335 38,449 29,943 31,217 110 98,573 73,684 69,614 46,154 39,336 30,835 31,949 120 100,014 72,366 68,804 45,724 39,818 31,298 32,747 130 101,045 71,565 67,776 45,486 40,005 31,507 33,572 140 102,336 70,962 66,847 45,424 39,999 31,568 34,409 150 104,168 70,444 66,218 45,481 40,000 31,660 35,166 160 106,545 70,140 65,622 45,635 40,001 31,733 35,829 170 108,184 70,563 65,038 45,515 39,903 31,738 36,487 180 109,626 70,967 64,298 45,288 39,934 31,849 37,106 190 110,447 71,261 63,827 45,120 39,829 31,797 37,646 200 110,594 71,281 63,770 45,131 39,770 31,814 38,139 225 112,119 73,508 65,027 45,736 40,466 32,590 38,954 250 114,119 74,137 65,938 46,623 41,099 33,273 39,262 275 115,152 74,120 66,702 47,211 41,963 34,050 39,336 300 116,369 74,969 66,953 47,987 42,952 34,829 39,434 325 117,688 75,642 67,674 49,059 43,920 35,705 39,659 350 118,825 75,760 69,197 50,172 45,133 36,859 39,867 375 119,873 75,809 70,351 51,357 46,389 38,123 39,957 400 121,066 76,034 70,790 52,441 47,671 39,433 39,971 450 123,205 76,558 71,880 54,334 49,847 41,805 40,278 500 124,701 76,888 72,964 56,506 51,565 44,066 40,510 550 126,106 77,039 73,572 57,967 53,406 46,421 40,710 600 129,527 77,442 73,731 59,201 54,890 48,351 40,876 650 131,227 77,983 74,403 60,078 56,075 49,702 40,818 700 132,932 78,820 74,825 60,629 57,314 50,963 40,542 750 134,126 79,817 76,037 61,039 58,625 52,202 40,229 800 135,325 80,180 77,497 61,753 60,069 53,613 39,920 850 136,205 80,559 77,950 62,211 61,380 54,873 39,448 900 137,068 80,415 78,834 62,599 62,643 56,115 39,061 950 140,225 79,839 79,120 62,991 63,815 57,342 38,724 1,000 141,991 79,013 79,317 63,275 65,012 58,675 38,392 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 69 June 2014 Table 5.2-21. Spawning WUA, Reach 4. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow Sockeye 10 26,670 185 544 2,236 1,971 550 20 30,139 1,464 775 3,017 2,559 743 30 34,570 2,006 969 3,505 3,071 911 40 36,574 2,174 1,028 3,991 3,452 967 50 38,660 2,441 1,090 4,402 3,773 1,055 60 40,667 2,738 1,174 4,754 4,107 1,080 70 42,620 3,048 1,354 4,889 4,403 1,157 80 44,566 3,365 1,558 4,998 4,644 1,217 90 46,415 3,557 1,686 5,002 4,782 1,265 100 49,000 3,721 1,759 4,953 4,850 1,292 110 52,800 3,889 1,810 4,707 4,909 1,320 120 56,740 3,991 1,874 4,381 4,936 1,335 130 59,240 4,099 1,975 4,053 4,988 1,342 140 60,292 4,256 2,029 3,819 4,990 1,337 150 61,602 4,449 2,025 3,607 4,934 1,324 160 62,806 4,613 1,974 3,394 4,869 1,309 170 64,650 4,763 1,890 3,204 4,779 1,315 180 65,848 4,934 1,788 3,144 4,668 1,324 190 66,802 5,103 1,702 3,169 4,568 1,329 200 67,725 5,250 1,617 3,363 4,556 1,335 225 74,079 5,591 1,457 3,819 4,488 1,429 250 79,270 5,822 1,454 4,324 4,454 1,554 275 81,701 5,905 1,572 4,740 4,488 1,696 300 83,832 5,821 1,819 5,095 4,686 1,843 325 85,750 5,781 2,074 5,422 4,998 2,012 350 86,453 5,748 2,303 5,823 5,363 2,159 375 88,054 5,773 2,541 6,238 5,742 2,345 400 89,335 5,829 2,883 6,539 6,093 2,590 450 90,523 5,841 3,841 7,110 6,597 3,088 500 91,751 5,994 4,768 7,506 7,070 3,664 550 93,681 6,720 5,471 7,785 7,520 4,256 600 95,014 7,536 5,929 7,889 7,936 4,910 650 96,226 8,305 6,365 7,962 8,353 5,441 700 97,352 8,939 6,777 7,877 8,639 5,813 750 97,717 9,486 7,062 7,699 8,749 6,068 800 97,998 9,853 7,188 7,449 8,727 6,225 850 98,378 10,233 7,230 7,068 8,664 6,309 900 98,776 10,535 7,173 6,616 8,525 6,302 950 99,160 10,766 7,058 6,120 8,335 6,227 1000 99,532 10,945 6,896 5,592 8,105 6,128 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 70 June 2014 Table 5.2-22. Fry rearing WUA, Reach 4. Flow (cfs) Surface Area Chinook Coho Dolly Varden Rainbow 10 26,670 18,442 12,221 19,236 9,760 20 30,139 16,802 8,756 17,377 7,684 30 34,570 15,620 6,142 15,838 6,484 40 36,574 14,257 4,940 14,713 6,261 50 38,660 13,152 4,220 13,134 6,098 60 40,667 12,075 3,619 11,613 5,507 70 42,620 10,940 3,208 10,709 4,978 80 44,566 10,314 3,265 10,401 4,735 90 46,415 10,071 3,494 10,477 4,490 100 49,000 10,279 4,036 11,063 4,631 110 52,800 10,499 4,279 11,693 4,739 120 56,740 11,092 4,964 12,891 5,103 130 59,240 11,823 5,830 14,484 5,496 140 60,292 12,979 7,044 16,086 6,244 150 61,602 14,492 8,673 17,530 7,390 160 62,806 16,358 10,447 18,546 8,785 170 64,650 18,073 11,808 19,291 9,883 180 65,848 19,413 12,662 19,769 10,562 190 66,802 20,384 13,255 20,171 10,970 200 67,725 20,399 12,373 19,942 10,397 225 74,079 21,498 12,544 20,757 10,416 250 79,270 22,425 12,843 23,419 10,891 275 81,701 24,854 15,465 26,401 13,252 300 83,832 27,779 17,970 28,068 16,275 325 85,750 30,111 19,663 28,928 18,663 350 86,453 31,279 20,564 29,410 19,897 375 88,054 32,251 21,350 29,472 20,978 400 89,335 32,455 21,376 29,394 21,267 450 90,523 32,735 21,875 29,271 21,523 500 91,751 33,046 22,166 28,553 21,477 550 93,681 32,651 21,466 27,666 20,951 600 95,014 31,974 20,882 27,308 20,337 650 96,226 31,851 20,803 26,810 20,269 700 97,352 31,520 20,340 25,964 19,792 750 97,717 30,693 19,582 24,842 18,906 800 97,998 29,739 18,726 23,398 17,895 850 98,378 28,622 17,763 22,079 16,591 900 98,776 27,561 16,766 20,819 15,254 950 99,160 26,581 15,914 19,613 13,995 1000 99,532 25,675 14,931 18,221 12,842 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 71 June 2014 Table 5.2-23. Adult and juvenile rearing WUA, Reach 4. Flow (cfs) Surface Area Coho Juvenile Dolly Varden Juvenile Rainbow Juvenile Dolly Varden Adult Rainbow Adult Chinook Juvenile 10 26,670 23,007 20,878 16,763 6,918 4,331 8,740 20 30,139 23,616 23,698 17,770 9,383 6,231 9,523 30 34,570 23,097 24,619 16,690 11,083 7,557 8,701 40 36,574 22,337 23,913 15,373 12,336 8,560 7,763 50 38,660 20,686 23,238 13,693 13,135 9,254 6,983 60 40,667 18,309 22,903 12,365 13,755 9,865 6,374 70 42,620 15,730 21,501 11,445 13,924 10,149 5,847 80 44,566 15,060 19,721 10,112 13,928 10,340 5,386 90 46,415 14,299 18,133 8,966 13,745 10,348 5,013 100 49,000 14,076 17,180 8,226 13,283 10,085 4,675 110 52,800 13,818 16,673 7,662 12,660 9,676 4,350 120 56,740 14,050 15,978 7,260 12,010 9,226 4,022 130 59,240 14,759 15,599 7,022 11,587 8,964 3,744 140 60,292 16,053 15,452 6,947 11,189 8,701 3,520 150 61,602 18,050 15,729 7,064 10,770 8,419 3,339 160 62,806 20,022 16,996 7,345 10,343 8,119 3,183 170 64,650 21,234 18,518 7,763 10,000 7,830 3,080 180 65,848 21,932 20,116 8,386 9,685 7,522 3,017 190 66,802 22,136 21,320 8,987 9,491 7,268 2,984 200 67,725 22,493 21,989 9,726 9,447 7,099 3,057 225 74,079 23,948 22,617 11,922 9,506 6,710 3,541 250 79,270 24,965 23,482 13,700 9,418 6,451 4,298 275 81,701 28,884 23,627 14,706 9,314 6,256 5,038 300 83,832 31,406 25,964 15,351 9,363 6,281 5,751 325 85,750 32,893 28,585 15,972 9,635 6,451 6,505 350 86,453 33,716 29,496 16,857 10,102 6,704 7,249 375 88,054 34,441 30,358 17,828 10,566 6,926 8,223 400 89,335 34,074 31,304 18,825 11,013 7,179 9,255 450 90,523 34,230 31,500 20,461 11,883 7,829 11,313 500 91,751 33,989 32,163 21,582 12,973 8,675 13,141 550 93,681 32,816 32,205 22,093 14,153 9,658 14,474 600 95,014 32,135 30,985 21,937 15,317 10,697 15,444 650 96,226 31,638 30,515 21,692 16,305 11,683 16,251 700 97,352 30,513 30,712 21,571 17,192 12,618 16,788 750 97,717 29,162 30,194 21,346 17,980 13,361 17,055 800 97,998 27,822 29,445 21,143 18,520 13,943 17,056 850 98,378 26,343 28,122 20,767 18,810 14,419 16,870 900 98,776 24,941 26,837 20,172 18,822 14,752 16,509 950 99,160 23,488 25,449 19,207 18,691 14,888 16,023 1000 99,532 21,921 24,511 18,274 18,431 14,859 15,384 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 72 June 2014 Figure 5.2-1. Spawning WUA, Reach 1 distributary. Figure 5.2-2. Fry rearing WUA, Reach 1 distributary. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 73 June 2014 Figure 5.2-3. Adult and juvenile rearing WUA, Reach 1 distributary. Figure 5.2-4. Spawning WUA, Reach 1 mainstem. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 74 June 2014 Figure 5.2-5. Fry rearing WUA, Reach 1 mainstem. Figure 5.2-6. Adult and juvenile rearing WUA, Reach 1 mainstem. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 75 June 2014 Figure 5.2-7. Spawning WUA, Reach 2 mainstem. Figure 5.2-8. Fry rearing WUA, Reach 2 mainstem. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 76 June 2014 Figure 5.2-9. Adult and juvenile rearing WUA, Reach 2 mainstem. Figure 5.2-10. Spawning WUA, Reach 3 mainstem. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 77 June 2014 Figure 5.2-11. Fry rearing WUA, Reach 3 mainstem. Figure 5.2-12. Adult and juvenile rearing WUA, Reach 3 mainstem. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 78 June 2014 Figure 5.2-13. Spawning WUA, Reach 3 side channels. Figure 5.2-14. Fry rearing WUA, Reach 3 side channels. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 79 June 2014 Figure 5.2-15. Adult and juvenile rearing WUA, Reach 3 side channels. Figure 5.2-16. Spawning WUA, Reach 3 combined. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 80 June 2014 Figure 5.2-17. Fry rearing WUA, Reach 3 combined. Figure 5.2-18. Adult and juvenile rearing WUA, Reach 3 combined. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 81 June 2014 Figure 5.2-19. Spawning WUA, Reach 4. Figure 5.2-20. Fry rearing WUA, Reach 4. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 82 June 2014 Figure 5.2-21. Adult and juvenile rearing WUA, Reach 4. 5.2.2. Reach 5 Connectivity Appendix 6 includes bed profiles and water surface elevations for a range of flows for each transect modeled for the Instream Flow Study. This appendix also graphically represents the percent of the total wetted width that meets depth criterion, as well as meeting the 10 percent continuous criterion per flow for Chinook, coho and sockeye salmon, and Dolly Varden char and rainbow trout. Table 5.2-24 shows that for 25 percent of total width, the passage depth criterion for Chinook salmon, is met on individual transects from 7 cfs – 30 cfs, with an average of 30 cfs. Discharges for continuous passage meet criterion at flows ranging from 7 cfs – 25 cfs, with an average of 25 cfs. The discharges at which both passage criteria are met range from 7 cfs – 30 cfs, with an average of 30 cfs. The 25 percent of total width, the passage depth criterion for coho and sockeye salmon, is met on individual transects at flows ranging from 7 cfs – 15 cfs, with an average of 10 cfs. Discharges for continuous passage meet criterion at flows ranging from 7 cfs – 10 cfs, with an average of 10 cfs. The discharges at which both passage criteria are met range from 7 cfs – 15 cfs, with an average of 10 cfs. For Dolly Varden and rainbow trout, the passage depth criterion for 25 percent of total width is met on individual transects at 7 cfs. Discharges for continuous passage meet criterion also at a flow of 7 cfs. The discharge at which both passage criteria are met is at a flow of 7 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 83 June 2014 Table 5.2-24. Discharge (cfs) for meeting salmonid passage criteria in Reach 5, Grant Creek. Species Passage Criteria T510 T520 Average Trout Total (25%) 7 7 7 Continuous (10%) 7 7 7 Both Criteria 7 7 7 Coho Total (25%) 15 7 10 Continuous (10%) 10 7 10 Both Criteria 15 7 10 Chinook Total (25%) 30 7 30 Continuous (10%) 25 7 25 Both Criteria 30 7 30 6 CONCLUSIONS 6.1. Grant Creek Aquatic Habitat Mapping Grant Creek is a higher gradient, very flashy stream. High flows and velocities limit the amount of LWD in the system because there are only a few places where LWD will collect in the main channel. Most wood is found in the distributary and the Reach 2/3 side channels, where flows are greatly reduced and are protected from the main discharges in Grant Creek. The system is dominated by riffles in the lower four reaches and cascades in Reach 5. Pools are also generally lacking in the mainstem. As with LWD, the exception is in the side channels and distributary. The other major habitat found with some abundance is undercut banks, primarily in Reaches 1 and 4. 6.2. Grant Creek Instream Flow Study 6.2.1. Grant Creek Habitat Preliminary results from the Instream Flow Study indicate that spawning is limited in Grant Creek due to lack of suitable spawning substrate; the substrate that is present is recruited from Reaches 5 and 6 (canyon). Substrates do not tend to be rounded, as observed in most high quality salmonid streams. The sediment from the canyon consists mostly of slate and greywacke (i.e., sandstone). When slate fractures, it tends to be platy (i.e., broad and flat), while greywacke fractures tend to be angular in nature (KHL 2014b). Spawning appears to be opportunistic and activity more directed by the presence of spawning sediment rather than by water depths and velocities. For example, KHL observed sockeye salmon spawning in 1 foot of depth and 1 foot per second velocities, while spawning activity was also observed about 30 feet away in the middle of the channel where depths of 3 to 4 feet and velocities up to 6 feet per second were noted. As indicated by the spawning WUA curves and field observations, much of the spawning occurs along the stream margins, where velocities and depths can be lower, and spawning substrates are perched. What was observed in the field, however, is that redds that were constructed along the stream margins at higher discharges were FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 84 June 2014 left dry and exposed as Grant Creek flows diminished. This was particularly noted for sockeye spawning; fish were observed spawning at much higher flows than coho (flows were relatively stable during the 2013 coho spawning period). Significant side channel habitat exists in Grant Creek, notably in Reaches 2 and 3. Salmon were observed spawning in these side channels, which provide reduced flows and complex rearing habitats. There is also a hydraulic control at the upper entrance to the Reach 1 distributary, which prevents water from coursing through these habitats at flows below approximately 190 cfs. The control at the upper end of this distributary consists mainly of logs and larger-sized sediments, which have been deposited there by Grant Creek at higher flows as the stream cuts transversely to the opposite bank just downstream of the distributary. Many of these side channel habitats are either dry or frozen during the winter period due to the reduced flows. There is most likely a substantial, yet unquantified loss of production in these side channels due to desiccation and freezing. Habitat for salmonids could likely be increased by several methods, notably: 1) altering the upstream control in the Reach 1 distributary, adding additional flow at optimal spawning and rearing periods; and 2) increasing base flows, which would result in more water into the side channels in Reaches 2 and 3. 6.2.2. Connectivity Flows in Reaches 5 and 6 (i.e., the canyon) would be reduced by Project operations. There has been concern that these reduced flows would affect upstream connectivity of pool and other habitats within Reach 5. Two transects, which represented the more sensitive types of habitats within the canyon, were modeled using the Oregon Method (Thompson 1972). Analysis of these habitats, using the criteria recommended by Thompson (1972), indicates that connectivity is accomplished for trout at a flow of 7 cfs for both total wetted and continuous width. Connectivity for Sockeye and Coho salmon was accomplished at flows ranging from 7 cfs – 15 cfs, averaging 10 cfs for both transects. Chinook salmon passage is accomplished at flows ranging from 7 cfs – 30 cfs, averaging 25 cfs (continuous passage) and 30 cfs (total wetted width). Current utilization of the canyon by the target species has not been incorporated into this report. More information can be found in the Fisheries Assessment (KHL 2014a). 7 VARIANCES FROM FERC-APPROVED STUDY PLAN AND PROPOSED MODIFICATIONS 7.1. Grant Creek Aquatic Habitat Mapping There were no substantial variances from the FERC- and agency-approved study plan. Production of several analyses (e.g., incubation analysis, as mentioned in the Study Objectives), will be completed after consultation with the Aquatics Resource Work Group (ARWG) and integration with other disciplines. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 85 June 2014 7.2 Grant Creek Instream Flow Study There were no substantial variances from the FERC- and agency-approved study plan as related to the Instream Flow Study. KHL added a study component to examine connectivity in Reach 5 because salmonids had been observed in the canyon. Information related to wetted perimeter analysis with substrate and effective spawning, and lateral connectivity, is being developed cooperatively with the Instream Flow Sub-Committee of the ARWG. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 86 June 2014 8 REFERENCES AEIDC (Arctic Environmental Information and Data Center). 1983. Summary of environmental knowledge of the proposed Grant Lake hydroelectric project area. Final Report submitted to Ebasco Services, Inc., Redmond, Washington, University of Alaska, Anchorage, Alaska. Bovee, K.D. 1982. A Guide to Stream Habitat Analysis Using the Instream Flow Incremental Methodology. Instream Flow Information Paper #12. U.S. Fish & Wildlife Service, Fort Collins, Colorado. Ebasco (Ebasco Services, Inc.). 1984. Grant Lake Hydroelectric Project Detailed Feasibility Analysis. Volume 2. Environmental Report. Rep. from Ebasco Services Incorporated, Bellevue, Washington. Envirosphere. 1987. Instream flow and habitat analysis Grant Lake hydroelectric project. Prepared for Kenai Hydro, Inc. HDR Alaska Inc. (HDR). 2009a. Grant Lake Hydroelectric Project Environmental Baseline Studies Report, 2009 Draft. Prepared for: Kenai Hydro, LLC. HDR. 2009b. Technical Memorandum - Review of 1986-1987 Grant Lake FERC application documents for instream flow considerations. Prepared for Grant Lake/Falls Creek Hydroelectric Technical Working Group. HDR. 2010. Grant Lake/Grant Creek And Falls Creek Project - Aquatic Resources Draft Study plan. Prepared For Kenai Hydro, LLC, Homer, Alaska. KHI (Kenai Hydro, Inc.). 1987a. Grant Lake hydroelectric project additional information. KHI. 1987b. Grant Lake hydroelectric project FERC No. 7633-002 additional information final report with agency license terms and conditions for selected alternative I and power contract information. KHL (Kenai Hydro, LLC). 2009. Pre-Application Document Grant Lake/Grant Creek and Falls Creek Project (FERC No. 13211 and 13212). August 2009. KHL. 2013. Grant Lake Project (FERC No 13212). Aquatic Resources Final Study Plan. March 2013. KHL. 2014a. Grant Lake Hydroelectric Project (FERC No. 13212). Aquatic Resources Study – Grant Creek, Alaska Fisheries Assessment, Final Report. Prepared by BioAnalysts, Inc. for Kenai Hydro, LLC. June 2014. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 87 June 2014 KHL. 2014b. Grant Lake Hydroelectric Project (FERC No. 13212). Water Resources Study – Geomorphology, Final Report. Prepared by Element Solutions for Kenai Hydro, LLC. June 2014. Overton, C.K., S.P. Wollrab, B.C. Roberts and M.A. Radko. 1997. R1/R4 (Northern/Intermountain Regions) Fish and Fish Habitat Standard Inventory Procedures Handbook. USDA, Forest Service, Intermountain Research Station. General Technical Report INT-GTR-346. Thompson, K. 1972. Determining Stream Flows For Fish. Presented at Instream Flow Requirement Workshop, Pacific Northwest River Basins Commission. March 1972. Trihey, E.W., and David Wegner. 1981. Field Data Collection Procedures for Use with the Habitat Simulation System of the Instream Flow Group. U.S. Fish and Wildlife Service, Fort Collins, Colorado. USFWS (U.S. Fish and Wildlife Service). 1961. Ptarmigan and Grant Lakes and Falls Creek, Kenai Peninsula. Juneau, AK. 25 pp. WDFW (Washington Department of Fish and Wildlife) and WDOE (Washington Department of Ecology). 2013. Instream flow study guidelines: technical and habitat suitability issues including fish preference curves. Updated April 1, 2013. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 88 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 1: Grant Creek Instream Flow Photos Appendix 1a Transect Photos at 17 cfs Calibration Flow Appendix 1b Transect Photos at 64 cfs Calibration Flow Appendix 1c Transect Photos at 132 cfs Calibration Flow Appendix 1d Transect Photos at 182 cfs Calibration Flow Appendix 1e Transect Photos at 706 cfs Calibration Flow FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 1a Transect Photos at 17 cfs Calibration Flow This sub-appendix contains the following figures: Figure A.1a-1. Dewatered side channel 100 at main channel at 17 cfs. Figure A.1a-2. Transect 100 at 17 cfs. Figure A.1a-3. Transect 120 at 17 cfs. Figure A.1a-4. Transect 130 at 17 cfs. Figure A.1a-5. Transect 140 at 17 cfs. Figure A.1a-6. Transect 150 at 17 cfs. Figure A.1a-7. Transect 160 at 17 cfs. Figure A.1a-8. Transect 200 at 17 cfs. Figure A.1a-9. Transect 220 at 17 cfs. Figure A.1a-10. Transect 230 at 17 cfs. Figure A.1a-11. Transect 230 side channel at 17 cfs. Figure A.1a-12. Transect 300 at 17 cfs. Figure A.1a-13. Transect 310 at 17 cfs. Figure A.1a-14. Transect 320 at 17 cfs. Figure A.1a-15. Transect 330 at 17 cfs. Figure A.1a-16. Transect 400 at 17 cfs. Figure A.1a-17. Transect 410 at 17 cfs. Figure A.1a-18. Transect 430 at 17 cfs. Figure A.1a-19. Transect 510 at 17 cfs. Figure A.1a-20. Transect 520 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 1 June 2014 Figure A.1a-1. Dewatered side channel 100 at main channel at 17 cfs. Figure A.1a-2. Transect 100 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 2 June 2014 Figure A.1a-3. Transect 120 at 17 cfs. Figure A.1a-4. Transect 130 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 3 June 2014 Figure A.1a-5. Transect 140 at 17 cfs. Figure A.1a-6. Transect 150 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 4 June 2014 Figure A.1a-7. Transect 160 at 17 cfs. Figure A.1a-8. Transect 200 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 5 June 2014 Figure A.1a-9. Transect 220 at 17 cfs. Figure A.1a-10. Transect 230 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 6 June 2014 Figure A.1a-11. Transect 230 side channel at 17 cfs. Figure A.1a-12. Transect 300 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 7 June 2014 Figure A.1a-13. Transect 310 at 17 cfs. Figure A.1a-14. Transect 320 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 8 June 2014 Figure A.1a-15. Transect 330 at 17 cfs. Figure A.1a-16. Transect 400 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 9 June 2014 Figure A.1a-17. Transect 410 at 17 cfs. Figure A.1a-18. Transect 430 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1a Page 10 June 2014 Figure A.1a-19. Transect 510 at 17 cfs. Figure A.1a-20. Transect 520 at 17 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 1b. Transect Photos at 64 cfs Calibration Flow This sub-appendix contains the following figures: Figure A.1b-1. Side channel 100 at Trail Lakes confluence at 64 cfs. Figure A.1b-2. Transect 100 at 64 cfs. Figure A.1b-3. Transect 110 at 64 cfs. Figure A.1b-4. Side channel 100 at main channel confluence at 64 cfs. Figure A.1b-5. Transect 120 at 64 cfs. Figure A.1b-6. Transect 130 at 64 cfs. Figure A.1b-7. Transect 140 at 64 cfs. Figure A.1b-8. Transect 150 at 64 cfs. Figure A.1b-9. Transect 160 at 64 cfs. Figure A.1b-10. Transect 200 at 64 cfs. Figure A.1b-11. Transect 210 side channel at 64 cfs. Figure A.1b-12. Transect 220 at 64 cfs. Figure A.1b-13. Transect 230 side channel at 64 cfs. Figure A.1b-14. Transect 300 at 64 cfs. Figure A.1b-15. Transect 310 at 64 cfs. Figure A.1b-16. Transect 320 at 64 cfs. Figure A.1b-17. Transect 330 at 64 cfs. Figure A.1b-18. Transect 400 at 64 cfs. Figure A.1b-19. Transect 410 at 64 cfs. Figure A.1b-20. Transect 430 at 64 cfs. Figure A.1b-21. Transect 510 at 64 cfs. Figure A.1b-22. Transect 520 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 1 June 2014 Figure A.1b-1. Side channel 100 at Trail Lakes confluence at 64 cfs. Figure A.1b-2. Transect 100 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 2 June 2014 Figure A.1b-3. Transect 110 at 64 cfs. Figure A.1b-4. Side channel 100 at main channel confluence at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 3 June 2014 Figure A.1b-5. Transect 120 at 64 cfs. Figure A.1b-6. Transect 130 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 4 June 2014 Figure A.1b-7. Transect 140 at 64 cfs. Figure A.1b-8. Transect 150 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 5 June 2014 Figure A.1b-9. Transect 160 at 64 cfs. Figure A.1b-10. Transect 200 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 6 June 2014 Figure A.1b-11. Transect 210 side channel at 64 cfs. Figure A.1b-12. Transect 220 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 7 June 2014 Figure A.1b-13. Transect 230 side channel at 64 cfs. Figure A.1b-14. Transect 300 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 8 June 2014 Figure A.1b-15. Transect 310 at 64 cfs. Figure A.1b-16. Transect 320 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 9 June 2014 Figure A.1b-17. Transect 330 at 64 cfs. Figure A.1b-18. Transect 400 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 10 June 2014 Figure A.1b-19. Transect 410 at 64 cfs. Figure A.1b-20. Transect 430 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 11 June 2014 Figure A.1b-21. Transect 510 at 64 cfs. Figure A.1b-22. Transect 520 at 64 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1b Page 12 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 1c. Transect Photos at 132 cfs Calibration Flow This sub-appendix contains the following figures: Figure A.1c-1. Side channel 100 at Trail Lakes confluence at 132 cfs. Figure A.1c-2. Transect 100 at 132 cfs. Figure A.1c-3. Transect 110 at 132 cfs. Figure A.1c-4. Side channel 100 at main channel confluence. Figure A.1c-5. Transect 120 at 132 cfs. Figure A.1c-6. Transect 130 at 132 cfs. Figure A.1c-7. Transect 140 at 132 cfs. Figure A.1c-8. Transect 150 at 132 cfs. Figure A.1c-9. Transect 160 at 132 cfs. Figure A.1c-10. Transect 200 at 132 cfs. Figure A.1c-11. Transect 210 side channel at 132 cfs. Figure A.1c-12. Transect 220 at 132 cfs. Figure A.1c-13. Transect 230 side channel at 132 cfs. Figure A.1c-14. Transect 230 at 132 cfs. Figure A.1c-15. Side channel 300 bottom confluence with main channel at 132 cfs. Figure A.1c-16. Transect 300 at 132 cfs. Figure A.1c-17. Transect 310 at 132 cfs. Figure A.1c-18. Transect 320 at 132 cfs. Figure A.1c-19. Transect 330 at 132 cfs. Figure A.1c-20. Transect 400 at 132 cfs. Figure A.1c-21. Transect 410 at 132 cfs. Figure A.1c-22. Transect 330 at 132 cfs. Figure A.1c-23. Transect 520 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 1 June 2014 Figure A.1c-1. Side channel 100 at Trail Lakes confluence at 132 cfs. Figure A.1c-2. Transect 100 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 2 June 2014 Figure A.1c-3. Transect 110 at 132 cfs. Figure A.1c-4. Side channel 100 at main channel confluence. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 3 June 2014 Figure A.1c-5. Transect 120 at 132 cfs. Figure A.1c-6. Transect 130 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 4 June 2014 Figure A.1c-7. Transect 140 at 132 cfs. Figure A.1c-8. Transect 150 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 5 June 2014 Figure A.1c-9. Transect 160 at 132 cfs. Figure A.1c-10. Transect 200 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 6 June 2014 Figure A.1c-11. Transect 210 side channel at 132 cfs. Figure A.1c-12. Transect 220 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 7 June 2014 Figure A.1c-13. Transect 230 side channel at 132 cfs. Figure A.1c-14. Transect 230 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 8 June 2014 Figure A.1c-15. Side channel 300 bottom confluence with main channel at 132 cfs. Figure A.1c-16. Transect 300 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 9 June 2014 Figure A.1c-17. Transect 310 at 132 cfs. Figure A.1c-18. Transect 320 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 10 June 2014 Figure A.1c-19. Transect 330 at 132 cfs. Figure A.1c-20. Transect 400 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 11 June 2014 Figure A.1c-21. Transect 410 at 132 cfs. Figure A.1c-22. Transect 330 at 132 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1c Page 12 June 2014 Figure A.1c-23. Transect 520 at 132 cfs FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 1d. Transect Photos at 182 cfs Calibration Flow This sub-appendix contains the following figures: Figure A.1d-1. Transect 120 at 182 cfs. Figure A.1d-2. Transect 130 at 182 cfs. Figure A.1d-3. Transect 140 at 182 cfs. Figure A.1d-4. Transect 150 at 182 cfs. Figure A.1d-5. Transect 160 at 182 cfs. Figure A.1d-6. Transect 230 side channel at 182 cfs. Figure A.1d-7. Transect 230 at 182 cfs. Figure A.1d-8. Transect 330 side channel 1 at 182 cfs. Figure A.1d-9. Transect 330 side channel 2 at 182 cfs. Figure A.1d-10. Transect 330 at 182 cfs. Figure A.1d-11. Transect 400 at 182 cfs. Figure A.1d-12. Transect 410 at 182 cfs. Figure A.1d-13. Transect 430 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 1 June 2014 Figure A.1d-1. Transect 120 at 182 cfs. Figure A.1d-2. Transect 130 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 2 June 2014 Figure A.1d-3. Transect 140 at 182 cfs. Figure A.1d-4. Transect 150 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 3 June 2014 Figure A.1d-5. Transect 160 at 182 cfs. Figure A.1d-6. Transect 230 side channel at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 4 June 2014 Figure A.1d-7. Transect 230 at 182 cfs. Figure A.1d-8. Transect 330 side channel 1 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 5 June 2014 Figure A.1d-9. Transect 330 side channel 2 at 182 cfs. Figure A.1d-10. Transect 330 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 6 June 2014 Figure A.1d-11. Transect 400 at 182 cfs. Figure A.1d-12. Transect 410 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 7 June 2014 Figure A.1d-13. Transect 430 at 182 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1d Page 8 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 1e. Transect Photos at 706 cfs Calibration Flow This sub-appendix contains the following figures: Figure A.1e-1. Side channel 100 at Trail Lakes confluence at 706 cfs. Figure A.1e-2. Transect 100 at 706 cfs. Figure A.1e-3. Transect 110 at 706 cfs. Figure A.1e-4. Transect 120 at 706 cfs. Figure A.1e-5. Transect 130 at 706 cfs. Figure A.1e-6. Transect 140 at 706 cfs. Figure A.1e-7. Transect 150 at 706 cfs. Figure A.1e-8. Transect 160 at 706 cfs. Figure A.1e-9. Transect 200 at 706 cfs. Figure A.1e-10. Transect 210 at 706 cfs. Figure A.1e-11. Transect 220 at 706 cfs. Figure A.1e-12. Transect 230 side channel at 706 cfs. Figure A.1e-13. Side channel 300 bottom confluence with main channel at 706 cfs. Figure A.1e-14. Transect 310 at 706 cfs. Figure A.1e-15. Transect 320 at 706 cfs. Figure A.1e-16. Transect 330 at 706 cfs. Figure A.1e-17. Transect 330 side channel (merged) at 706 cfs. Figure A.1e-18. Transect 330 at 706 cfs. Figure A.1e-19. Transect 400 at 706 cfs. Figure A.1e-20. Transect 410 at 706 cfs. Figure A.1e-21. Transect 430 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 1 June 2014 Figure A.1e-1. Side channel 100 at Trail Lakes confluence at 706 cfs. Figure A.1e-2. Transect 100 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 2 June 2014 Figure A.1e-3. Transect 110 at 706 cfs. Figure A.1e-4. Transect 120 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 3 June 2014 Figure A.1e-5. Transect 130 at 706 cfs. Figure A.1e-6. Transect 140 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 4 June 2014 Figure A.1e-7. Transect 150 at 706 cfs. Figure A.1e-8. Transect 160 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 5 June 2014 Figure A.1e-9. Transect 200 at 706 cfs. Figure A.1e-10. Transect 210 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 6 June 2014 Figure A.1e-11. Transect 220 at 706 cfs. Figure A.1e-12. Transect 230 side channel at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 7 June 2014 Figure A.1e-13. Side channel 300 bottom confluence with main channel at 706 cfs. Figure A.1e-14. Transect 310 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 8 June 2014 Figure A.1e-15. Transect 320 at 706 cfs. Figure A.1e-16. Transect 330 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 9 June 2014 Figure A.1e-17. Transect 330 side channel (merged) at 706 cfs. Figure A.1e-18. Transect 330 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 10 June 2014 Figure A.1e-19. Transect 400 at 706 cfs. Figure A.1e-20. Transect 410 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 11 June 2014 Figure A.1e-21. Transect 430 at 706 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 1e Page 12 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 2: HSC Curves Appendix 2a. Habitat Availability and Utilization Appendix 2b. HSC Curves FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2 Page 1 June 2014 INTRODUCTION As part of the Grant Creek Instream Flow Study, Kenai Hydro, LLC (KHL) collected habitat utilization and habitat availability data for Chinook, sockeye, and coho salmon spawning in Grant Creek. These curves, once referred to as preference curves, are now called habitat suitability criteria (HSC) curves. HSC curve verification studies consist of three parts: 1. Determination of proportional habitat availability; 2. Determination of fish habitat utilization; and 3. Analysis of fish preference by determining ratio of habitat utilization to habitat availability. Curve development follows guidelines present in WDFW/WDOE (2013), which draws from Orth, Jones, and Maughan (1981), Bovee (1986), Slauson (1988), and Beecher et al. (1993). METHODS KHL consultants surveyed Grant Creek looking for Chinook, sockeye, and coho salmon spawning. Only measurements of fish observed actually spawning were taken. In the case of aggregate spawning (as is often observed with sockeye salmon), measurement of two of the fish in the aggregate were taken. Measurements of mean column velocity, depth, and substrate were taken on both sides of each redd measured. These were measurements of habitat utilization. Location of the redds (relative to transects), time, and flow in Grant Creek were noted. Once the locations of the fish were noted and measurements of utilization were taken, Grant Creek cross sections were taken downstream, upstream, and in the vicinity of the observed redds. If there were instream flow transects in the vicinity of the observed redds, the transect models were run at the flow at which spawning was observed. If there were no transects in the vicinity of the observed redds, measurements of depth and velocity were taken in Grant Creek below, across, and above the observed redds. RESULTS A total of 99 sockeye salmon, 47 coho salmon, and 3 Chinook salmon redds were measured. Due to long sample size, Chinook salmon data were not used; in this case and for rearing life history stages of all species in Grant Creek, literature curves based upon other sources (in Alaska, when available) were used. Table A.2-1 summarized flows, species, and locations of spawning sockeye and coho salmon. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2 Page 2 June 2014 Table A.2-1. Summary of habitat utilization data for Grant Creek sockeye and coho salmon. Date 8/30/13 8/31/13 9/2/13 9/3/13 9/10/13 9/24/13 10/11/14 10/12/14 10/21/14 Flow (cfs) 389 386 338 360 469 187 169 179 285 Transect Sockeye Sockeye Sockeye Sockeye Sockeye Sockeye Coho Coho Coho 110 * 120 * * * * * 130 * * * * * 140 * * * * * 150 **** *** 160 * * * * 200 210 * 220 * * * * * * 230=MC * * * * * 300 * * 310 * * * * 320 * * * * 330‐MC ******* 330‐SC 330‐TC 400 * * * * * 410 * * * * 430 * * * 510 * other * * Below Weir * * * Total 302318167 5 22214 Sockeye and coho salmon spawning HSC curves are presented in Appendix 2a. Literature-based curves for Chinook salmon, rainbow trout, and Dolly Varden char spawning, and rearing curves for all salmonids species found in Grant Creek are presented in Appendix 2b. LITERATURE CITED Beecher, H.A., T.H. Johnson, and J.P. Carleton. 1993. Predicting microdistributions of steelhead parr (Oncorhynchus mykiss) parr from depth and velocity preference criteria: test of an assumption of the Instream Flow Incremental Methodology. Canadian Journal of Fisheries and Aquatic Sciences 50 (11): 2380-2387. Bovee, K.D. 1986. Development and evaluation of habitat suitability criteria for use in the Instream Flow Incremental Methodology. Instream Flow Information Paper 21. U.S. Fish and Wildlife Service Biological Report 86(7). 235 pp. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2 Page 3 June 2014 Orth, D.J., R.N. Jones, and O.E. Maughan. 1981. Considerations in the development of curves for habitat suitability criteria. Pp. 124-133 in: N.B. Armantrout (ed.), Acquisition and utilization of aquatic habitat inventory information. Western Division, American Fisheries Society. Slauson, W.L. 1988. Constructing suitability curves from data. Pp. 225-258 in: K. Bovee and J.R. Zuboy (eds.), Proceedings of a workshop on the development and evaluation of habitat suitability criteria. U.S. Fish and Wildlife Service Biological Report 88(11). 407 pp. WDFW (Washington Department of Fish and Wildlife) and WDOE (Washington Department of Ecology). 2013. Instream flow study guidelines: technical and habitat suitability issues including fish preference curves. Updated April 1, 2013. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2 Page 4 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 2a. Habitat Availability and Utilization This sub-appendix contains the following figures and tables: Figure A.2a-1. Sockeye salmon spawning habitat availability, depth. Figure A.2a-2. Sockeye salmon spawning habitat availability, velocity. Figure A.2a-3. Sockeye salmon spawning depth utilization. Figure A.2a-4. Sockeye salmon spawning velocity utilization. Figure A.2a-5. Coho salmon spawning habitat availability, depth. Figure A.2a-6. Coho salmon spawning habitat availability, velocity. Figure A.2a-7. Coho salmon spawning depth utilization. Figure A.2a-8. Coho salmon spawning velocity utilization Table A.2a-1. Sockeye salmon spawning depth, observed vs expected. Table A.2a-2. Sockeye salmon spawning velocity, observed vs expected. Table A.2a-3. Coho salmon spawning depth, observed vs expected. Table A.2a-4. Coho salmon spawning velocity, observed vs expected. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2a Page 1 June 2014 Figure A.2a-1. Sockeye salmon spawning habitat availability, depth. Figure A.2a-2. Sockeye salmon spawning habitat availability, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2a Page 2 June 2014 Figure A.2a-3. Sockeye salmon spawning depth utilization. Figure A.2a-4. Sockeye salmon spawning velocity utilization. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2a Page 3 June 2014 Table A.2a-1. Sockeye salmon spawning depth, observed vs expected. Depth Interval O/E Ratio Preference Min Max 0 0.29 0.06 0.02 0.30 0.49 0.06 0.02 0.50 0.69 0.85 0.34 0.70 0.79 1.61 0.64 0.80 0.89 1.64 0.65 0.90 1.09 2.52 1.00 1.10 1.19 0.99 0.39 1.20 1.39 2.48 0.98 1.40 1.59 1.99 0.79 1.60 1.79 0.66 0.26 1.80 1.99 0.55 0.22 2.00 2.29 1.00 0.40 2.30 2.79 0.37 0.15 2.80 3.29 0.00 0.00 3.30 4.49 0.00 0.00 Table A.2a-2. Sockeye salmon spawning velocity, observed vs expected. Velocity Interval O/E Ratio Preference Min Max 0.00 0.09 0.09 0.03 0.10 0.19 0.59 0.21 0.20 0.49 1.43 0.52 0.50 0.79 1.13 0.41 0.80 1.29 2.11 0.76 1.30 1.79 2.77 1.00 1.80 2.19 2.34 0.84 2.20 2.59 1.90 0.69 2.60 3.09 1.63 0.59 3.10 3.49 0.81 0.29 3.50 3.89 0.97 0.35 3.90 4.39 0.59 0.21 4.40 4.79 0.29 0.11 4.80 5.49 0.48 0.17 5.50 6.09 0.00 0.00 6.10 7.49 0.00 0.00 7.50 9.59 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2a Page 4 June 2014 Figure A.2a-5. Coho salmon spawning habitat availability, depth. Figure A.2a-6. Coho salmon spawning habitat availability, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2a Page 5 June 2014 Figure A.2a-7. Coho salmon spawning depth utilization. Figure A.2a-8. Coho salmon spawning velocity utilization FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2a Page 6 June 2014 Table A.2a-3. Coho salmon spawning depth, observed vs expected. Depth Interval O/E Ratio Preference Min Max 0.00 0.09 0.00 0.00 0.10 0.29 0.00 0.00 0.30 0.39 0.14 0.05 0.40 0.59 0.14 0.05 0.60 0.79 2.37 0.80 0.80 1.09 2.96 1.00 1.10 1.29 0.94 0.32 1.30 1.49 1.24 0.42 1.50 1.79 1.75 0.59 1.80 2.09 2.16 0.73 2.10 2.39 0.56 0.19 2.40 3.89 0.78 0.26 Table A.2a-4. Coho salmon spawning velocity, observed vs expected. Velocity Interval O/E Ratio Preference Min Max 0.00 0.09 0.29 0.12 0.10 0.19 0.56 0.22 0.20 0.29 0.36 0.14 0.30 0.49 1.37 0.54 0.50 0.89 1.76 0.70 0.90 1.19 1.92 0.76 1.20 1.49 2.53 1.00 1.50 1.79 1.16 0.46 1.80 2.19 1.88 0.74 2.20 2.59 1.43 0.56 2.60 2.89 0.96 0.38 2.90 3.19 0.39 0.16 3.30 3.69 0.45 0.18 3.70 4.19 0.38 0.15 4.20 5.09 0.18 0.07 5.10 7.19 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 2b. HSC Curves This sub-appendix contains the following figures and tables: Figure A.2b-1. Final HSC curve for sockeye salmon spawning, depth. Figure A.2b-2. Final HSC curve for sockeye salmon spawning, velocity. Figure A.2b-3. Final HSC curve for coho salmon spawning, depth. Figure A.2b-4. Final HSC curve for coho salmon spawning, velocity. Figure A.2b-5. Proposed HSC curve for coho salmon juvenile rearing, depth. Figure A.2b-6. Proposed HSC curve for coho salmon juvenile rearing, velocity. Figure A.2b-7. Proposed HSC curve for coho salmon fry rearing, depth. Figure A.2b-8. Proposed HSC curve for coho salmon fry rearing, velocity. Figure A.2b-9. Proposed HSC curve for Chinook salmon spawning, depth. Figure A.2b-10. Proposed HSC curve for Chinook salmon spawning, velocity. Figure A.2b-11. Proposed HSC curve for Chinook salmon juvenile rearing, depth. Figure A.2b-12. Proposed HSC curve for Chinook salmon juvenile rearing, velocity. Figure A.2b-13. Proposed HSC curve for Chinook salmon fry rearing, depth. Figure A.2b-14. Proposed HSC curve for Chinook salmon fry rearing, velocity. Figure A.2b-15. Proposed HSC curve for Dolly Varden spawning, depth. Figure A.2b-16. Proposed HSC curve for Dolly Varden spawning, velocity. Figure A.2b-17. Proposed HSC curve for Dolly Varden juvenile rearing, depth. Figure A.2b-18. Proposed HSC curve for Dolly Varden juvenile rearing, velocity. Figure A.2b-19. Proposed HSC curve for Dolly Varden fry rearing, depth. Figure A.2b-20. Proposed HSC curve for Dolly Varden fry rearing, velocity. Figure A.2b-21. Proposed HSC curve for Dolly Varden adult rearing, depth. Figure A.2b-22. Proposed HSC curve for Dolly Varden adult rearing, velocity. Figure A.2b-23. Proposed HSC curve for rainbow trout spawning, depth. Figure A.2b-24. Proposed HSC curve for rainbow trout spawning, velocity. Figure A.2b-25. Proposed HSC curve for rainbow trout juvenile rearing, depth. Figure A.2b-26. Proposed HSC curve for rainbow trout juvenile rearing, velocity. Figure A.2b-27. Proposed HSC curve for rainbow trout fry rearing, depth. Figure A.2b-28. Proposed HSC curve for rainbow trout fry rearing, velocity. Figure A.2b-29. Proposed HSC curve for rainbow trout adult rearing, depth. Figure A.2b-30. Proposed HSC curve for rainbow trout adult rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Table A.2b-1. Final HSC curve for sockeye salmon spawning depth. Table A.2b-2. Final HSC curve for sockeye salmon spawing, velocity. Table A.2b-3. Final HSC curve for coho salmon spawing, depth. Table A.2b-4. Final HSC curve for coho salmon spawning, velocity. Table A.2b-5. Proposed HSC curve for coho salmon juvenile rearing, depth. Table A.2b-6. Proposed HSC curve for coho salmon juvenile rearing, velocity. Table A.2b-7. Proposed HSC curve for coho salmon fry rearing, depth. Table A.2b-8. Proposed HSC curve for coho salmon fry rearing, velocity. Table A.2b-9. Proposed HSC curve for Chinook salmon spawning, depth. Table A.2b-10. Proposed HSC curve for Chinook salmon spawning, velocity. Table A.2b-11. Proposed HSC curve for Chinook salmon juvenile rearing, depth. Table A.2b-12. Proposed HSC curve for Chinook salmon juvenile rearing, velocity. Table A.2b-13. Proposed HSC curve for Chinook salmon fry rearing, depth. Table A.2b-14. Proposed HSC curve for Chinook salmon fry rearing, velocity. Table A.2b-15. Proposed HSC curve for Dolly Varden spawning, depth. Table A.2b-16. Proposed HSC curve for Dolly Varden spawning, velocity. Table A.2b-17. Proposed HSC curve for Dolly Varden juvenile rearing, depth. Table A.2b-18. Proposed HSC curve for Dolly Varden juvenile rearing, velocity. Table A.2b-19. Proposed HSC curve for Dolly Varden fry rearing, depth. Table A.2b-20. Proposed HSC curve for Dolly Varden fry rearing, velocity. Table A.2b-21. Proposed HSC curve for Dolly Varden adult rearing, depth. Table A.2b-22. Proposed HSC curve for Dolly Varden adult rearing, velocity. Table A.2b-23. Proposed HSC curve for rainbow trout spawning, depth. Table A.2b-24. Proposed HSC curve for rainbow trout spawning, velocity. Table A.2b-25. Proposed HSC curve for rainbow trout juvenile rearing, depth. Table A.2b-26. Proposed HSC curve for rainbow trout juvenile rearing, velocity. Table A.2b-27. Proposed HSC curve for rainbow trout fry rearing, depth. Table A.2b-28. Proposed HSC curve for rainbow trout fry rearing, velocity. Table A.2b-29. Proposed HSC curve for rainbow trout adult rearing, depth. Table A.2b-30. Proposed HSC curve for rainbow trout adult rearing, velocity. Table A.2b-31. Substrate classification and HSC values. Table A.2b-32. Cover classification and HSC values. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 1 June 2014 Figure A.2b-1. Final HSC curve for sockeye salmon spawning, depth. Depth Pref 0.00 0.00 0.40 0.00 1.00 1.00 10.00 1.00 Table A.2b-1. Final HSC curve for sockeye salmon spawning depth. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 2 June 2014 Figure A.2b-2. Final HSC curve for sockeye salmon spawning, velocity. Velocity Pref 0.00 0.03 0.05 0.03 0.35 0.52 1.30 1.00 1.79 1.00 3.70 0.35 5.15 0.17 5.80 0.00 10.00 0.00 Table A.2b-2. Final HSC curve for sockeye salmon spawing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 3 June 2014 Figure A.2b-3. Final HSC curve for coho salmon spawning, depth. Depth Pref 0.00 0.00 0.20 0.00 0.35 0.03 0.50 0.05 0.70 0.80 0.80 1.00 10.00 1.00 Table A.2b-3. Final HSC curve for coho salmon spawing, depth. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 4 June 2014 Figure A.2b-4. Final HSC curve for coho salmon spawning, velocity. Velocity Pref 0.00 0.03 0.05 0.03 0.35 0.52 1.30 1.00 1.79 1.00 3.70 0.35 5.15 0.17 5.80 0.00 10.00 0.00 Table A.2b-4. Final HSC curve for coho salmon spawning, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 5 June 2014 Figure A.2b-5. Proposed HSC curve for coho salmon juvenile rearing, depth. Figure A.2b-6. Proposed HSC curve for coho salmon juvenile rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 6 June 2014 Table A.2b-5. Proposed HSC curve for coho salmon juvenile rearing, depth. Depth Baldrige Cooper SMC Falls Proposed 0.00 0.00 0.00 0.00 0.00 0.00 0.10 1.00 1.00 0.00 0.00 0.00 0.15 1.00 1.00 0.60 0.00 0.60 0.20 1.00 1.00 0.80 0.00 0.80 0.25 1.00 1.00 1.00 0.00 1.00 0.33 1.00 1.00 1.00 0.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 2.00 1.00 1.00 1.00 1.00 1.00 2.40 1.00 0.80 1.00 1.00 1.00 2.80 1.00 0.60 1.00 1.00 1.00 3.00 1.00 0.40 1.00 1.00 1.00 3.50 1.00 0.25 1.00 1.00 1.00 4.00 1.00 0.10 0.50 1.00 1.00 4.50 1.00 0.00 0.00 1.00 1.00 5.00 1.00 0.00 0.00 1.00 1.00 10.00 1.00 0.00 0.00 1.00 1.00 Table A.2b-6. Proposed HSC curve for coho salmon juvenile rearing, velocity. Velocity Baldrige Cooper SMC Falls Proposed 0.00 1.00 1.00 1.00 0.20 1.00 0.40 1.00 1.00 1.00 0.68 1.00 0.45 0.90 1.00 0.90 0.74 1.00 0.50 0.80 1.00 0.80 0.80 1.00 0.60 0.76 1.00 0.66 0.92 1.00 0.67 0.73 1.00 0.56 1.00 1.00 0.80 0.68 1.00 0.38 1.00 1.00 1.00 0.60 1.00 0.10 1.00 1.00 1.25 0.50 0.72 0.00 1.00 0.72 1.50 0.40 0.44 0.00 1.00 0.40 1.80 0.28 0.10 0.00 1.00 0.28 2.00 0.20 0.08 0.00 1.00 0.20 2.50 0.05 0.04 0.00 1.00 0.05 2.60 0.04 0.03 0.00 1.00 0.04 3.00 0.00 0.00 0.00 0.71 0.00 4.00 0.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 7 June 2014 Figure A.2b-7. Proposed HSC curve for coho salmon fry rearing, depth. Figure A.2b-8. Proposed HSC curve for coho salmon fry rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 8 June 2014 Table A.2b-7. Proposed HSC curve for coho salmon fry rearing, depth. Depth Baldrige L&N SMC FC Cooper Proposed 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 1.00 0.25 0.17 0.25 0.00 0.00 0.10 1.00 0.50 0.34 0.50 0.00 0.00 0.20 1.00 1.00 0.67 1.00 0.50 0.67 0.30 1.00 1.00 1.00 1.00 1.00 1.00 0.50 1.00 1.00 1.00 1.00 1.00 1.00 0.80 0.90 1.00 1.00 1.00 1.00 1.00 1.00 0.80 1.00 1.00 1.00 1.00 1.00 1.50 0.40 1.00 1.00 1.00 1.00 1.00 2.00 0.10 1.00 1.00 1.00 1.00 1.00 2.10 0.08 1.00 0.95 1.00 1.00 1.00 2.50 0.00 1.00 0.75 1.00 1.00 1.00 3.00 0.00 1.00 0.50 1.00 1.00 1.00 4.00 0.00 1.00 0.00 1.00 1.00 1.00 5.10 0.00 1.00 0.00 1.00 1.00 1.00 Table A.2b-8. Proposed HSC curve for coho salmon fry rearing, velocity. Velocity Baldrige L&N SMC Falls Cooper Proposed 0.00 1.00 1.00 1.00 1.00 1.00 1.00 0.15 1.00 1.00 1.00 1.00 1.00 1.00 0.20 1.00 1.00 1.00 1.00 0.80 1.00 0.30 0.90 1.00 0.95 1.00 0.40 0.95 0.36 0.84 0.58 0.77 1.00 0.38 0.77 0.40 0.80 0.30 0.65 0.94 0.37 0.65 0.50 0.70 0.27 0.35 0.80 0.33 0.35 0.60 0.60 0.23 0.30 0.74 0.30 0.30 1.00 0.10 0.10 0.10 0.50 0.17 0.17 1.20 0.09 0.00 0.00 0.38 0.10 0.10 1.50 0.08 0.00 0.00 0.20 0.00 0.00 2.00 0.05 0.00 0.00 0.10 0.00 0.00 2.50 0.00 0.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 9 June 2014 Figure A.2b-9. Proposed HSC curve for Chinook salmon spawning, depth. Figure A.2b-10. Proposed HSC curve for Chinook salmon spawning, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 10 June 2014 Table A.2b-9. Proposed HSC curve for Chinook salmon spawning, depth. Depth Cooper Cr WDFW BC Delphi Proposed 0.00 0.00 0.00 0.00 0.00 0.35 0.00 0.00 0.00 0.00 0.75 0.00 0.64 0.00 0.00 0.79 0.16 0.70 0.00 0.16 0.85 0.40 0.80 0.03 0.40 1.00 1.00 0.95 0.11 1.00 1.05 1.00 1.00 0.14 1.00 1.25 1.00 1.00 0.25 1.00 1.35 1.00 0.92 0.31 1.00 1.75 1.00 0.30 0.52 1.00 2.62 1.00 0.30 1.00 1.00 5.00 1.00 0.30 1.00 1.00 6.00 1.00 0.24 1.00 1.00 10.00 1.00 0.00 1.00 1.00 Table A.2b-10. Proposed HSC curve for Chinook salmon spawning, velocity. Velocity Cooper Cr WDFW BC Delphi Proposed 0.00 0.00 0.00 0.00 0.00 0.50 0.00 0.00 0.00 0.00 0.55 0.10 0.00 0.09 0.10 0.65 0.30 0.20 0.26 0.30 0.82 0.64 0.22 0.55 0.64 1.00 1.00 0.24 0.92 1.00 1.04 1.00 0.24 1.00 1.00 1.15 1.00 0.25 1.00 1.00 1.95 1.00 1.00 1.00 1.00 2.65 1.00 1.00 1.00 1.00 2.95 1.00 0.60 1.00 1.00 3.75 1.00 0.30 1.00 1.00 4.00 1.00 0.24 1.00 1.00 4.10 0.95 0.22 1.00 0.95 5.00 0.50 0.00 0.76 0.50 6.00 0.00 0.00 0.50 0.00 7.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 11 June 2014 Figure A.2b-11. Proposed HSC curve for Chinook salmon juvenile rearing, depth. Figure A.2b-12. Proposed HSC curve for Chinook salmon juvenile rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 12 June 2014 Table A.2b-11. Proposed HSC curve for Chinook salmon juvenile rearing, depth. Depth WDFW 2013 Oak Grove R2-White Hampton WDFW 1987 Wampler Proposed 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.25 0.00 0.00 0.30 0.00 0.40 1.00 0.19 0.00 0.00 0.45 0.00 0.50 0.05 0.70 0.32 0.75 0.19 0.80 0.59 0.90 0.56 1.00 1.00 1.05 0.30 1.10 0.83 1.20 0.89 1.00 1.25 0.66 1.30 1.00 1.40 1.00 1.50 1.00 1.60 1.00 1.00 1.00 1.65 0.80 1.80 0.82 2.00 1.00 1.00 1.00 2.25 1.00 2.35 1.00 2.50 0.00 2.65 0.70 5.00 0.70 1.00 1.00 1.00 1.00 0.00 1.00 Table A.2b-12. Proposed HSC curve for Chinook salmon juvenile rearing, velocity. Velocity WDFW 2013 Oak Grove R2- White Hampton WDFW 1987 WDFW 2000 Wampler Burger Proposed 0.00 0.25 0.10 1.00 1.00 0.23 0.00 0.00 0.60 0.60 0.05 0.09 0.10 0.75 0.75 0.15 0.61 0.20 1.00 0.20 0.16 0.80 0.80 0.25 0.40 0.30 1.00 1.00 0.90 0.90 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 13 June 2014 Velocity WDFW 2013 Oak Grove R2- White Hampton WDFW 1987 WDFW 2000 Wampler Burger Proposed 0.35 0.77 0.26 0.40 0.89 0.50 1.00 1.00 0.45 0.93 0.50 1.00 1.00 0.55 1.00 0.65 0.60 0.69 0.65 0.65 1.00 1.00 0.70 1.00 1.00 1.00 0.80 0.40 0.64 0.90 1.00 1.00 0.31 0.90 0.60 1.10 0.90 0.43 1.20 0.11 0.32 1.30 0.56 0.75 1.00 1.40 0.25 1.45 0.60 1.50 0.23 1.60 0.25 0.20 0.25 1.70 0.84 1.72 0.15 1.75 0.50 1.80 0.10 1.90 0.31 2.00 0.15 0.00 0.10 0.15 2.01 0.10 2.25 0.08 2.30 0.00 2.50 0.15 2.60 0.06 2.75 0.10 3.00 0.00 0.03 3.10 0.00 3.20 0.00 0.00 3.55 0.10 3.40 0.00 3.60 0.00 3.85 0.00 4.00 0.00 0.00 5.00 0.00 0.00 0.00 8.00 0.00 0.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 14 June 2014 Figure A.2b-13. Proposed HSC curve for Chinook salmon fry rearing, depth. Figure A.2b-14. Proposed HSC curve for Chinook salmon fry rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 15 June 2014 Table A.2b-13. Proposed HSC curve for Chinook salmon fry rearing, depth. Depth Cooper Cr BC Delphi Proposed 0.00 0.00 0.00 0.00 0.03 0.00 0.08 0.00 0.10 0.00 0.16 0.00 0.30 1.00 0.49 1.00 0.49 1.00 0.63 1.00 0.72 1.00 1.00 1.00 6.00 1.00 1.00 1.00 Table A.2b-14. Proposed HSC curve for Chinook salmon fry rearing, velocity. Velocity Cooper Cr BC Delphi Burger Proposed 0.00 1.00 0.00 0.60 1.00 0.26 1.00 0.52 0.86 1.00 0.40 1.00 0.64 1.00 1.00 0.50 0.87 0.72 0.80 0.87 0.60 0.73 0.81 0.65 0.65 0.82 0.44 0.99 0.63 0.63 0.85 0.40 1.00 0.63 0.63 0.90 0.33 1.00 0.62 0.62 1.00 0.20 1.00 0.60 0.60 1.08 0.18 1.00 0.55 0.55 1.64 0.07 0.77 0.20 0.20 2.00 0.00 0.57 0.12 0.12 2.10 0.00 0.52 0.10 0.10 2.30 0.00 0.41 0.00 0.00 2.46 0.00 0.32 0.00 0.00 3.28 0.00 0.10 0.00 0.00 4.10 0.00 0.04 0.00 0.00 4.36 0.00 0.00 0.00 0.00 7.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 16 June 2014 Figure A.2b-15. Proposed HSC curve for Dolly Varden spawning, depth. Figure A.2b-16. Proposed HSC curve for Dolly Varden spawning, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 17 June 2014 Table A.2b-15. Proposed HSC curve for Dolly Varden spawning, depth. Depth Baldrige Cooper Cr WDFW Falls Cr Proposed 0.00 0.00 0.00 0.00 0.00 0.00 0.15 0.00 0.00 0.00 0.00 0.00 0.20 0.00 0.00 0.10 0.00 0.00 0.25 0.00 0.05 0.20 0.00 0.00 0.30 0.10 0.10 0.30 0.00 0.10 0.50 0.50 0.30 0.70 0.67 0.67 0.60 1.00 0.40 0.90 1.00 1.00 0.65 1.00 0.45 1.00 1.00 1.00 1.00 1.00 1.00 0.51 1.00 1.00 1.15 1.00 1.00 0.30 1.00 1.00 1.85 1.00 1.00 0.25 1.00 1.00 2.00 1.00 1.00 0.25 1.00 1.00 4.00 0.10 1.00 0.25 1.00 1.00 6.00 0.00 1.00 0.25 1.00 1.00 10.00 0.00 1.00 0.00 1.00 1.00 Table A.2b-16. Proposed HSC curve for Dolly Varden spawning, velocity. Velocity Baldrige Cooper Cr WDFW Falls Proposed 0.00 0.00 0.00 0.15 0.00 0.00 0.20 0.00 0.20 0.42 1.00 0.20 0.25 0.00 0.33 0.48 1.00 0.33 0.50 0.33 1.00 0.81 1.00 1.00 0.55 0.40 1.00 0.88 1.00 1.00 0.75 0.67 1.00 1.00 1.00 1.00 0.85 0.80 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.82 1.00 1.00 1.15 1.00 1.00 0.63 1.00 1.00 2.00 1.00 1.00 0.26 1.00 1.00 2.25 1.00 1.00 0.15 0.79 0.79 2.50 1.00 1.00 0.12 0.58 0.58 3.20 0.53 0.53 0.05 0.00 0.00 3.65 0.23 0.23 0.00 0.00 0.00 4.00 0.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 18 June 2014 Figure A.2b-17. Proposed HSC curve for Dolly Varden juvenile rearing, depth. Figure A.2b-18. Proposed HSC curve for Dolly Varden juvenile rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 19 June 2014 Table A.2b-17. Proposed HSC curve for Dolly Varden juvenile rearing, depth. Depth Baldrige Cooper Cr WDFW Falls Cr Proposed 0.00 0.00 0.00 0.00 0.00 0.00 0.10 1.00 0.00 0.00 0.00 0.00 0.20 1.00 0.00 0.00 0.00 0.00 0.30 1.00 1.00 0.00 0.00 1.00 0.33 1.00 1.00 0.00 0.00 1.00 0.45 1.00 1.00 0.00 0.18 1.00 0.65 1.00 1.00 0.15 0.48 1.00 1.00 1.00 1.00 0.26 1.00 1.00 1.15 1.00 1.00 0.30 1.00 1.00 1.25 1.00 1.00 0.70 1.00 1.00 1.65 1.00 1.00 1.00 1.00 1.00 1.85 1.00 1.00 1.00 1.00 1.00 2.00 1.00 1.00 0.97 1.00 1.00 2.50 0.80 1.00 0.87 1.00 1.00 2.85 0.66 1.00 0.80 1.00 1.00 2.95 0.62 1.00 0.55 1.00 1.00 3.00 0.60 1.00 0.55 1.00 1.00 4.00 0.20 1.00 0.47 1.00 1.00 5.00 0.10 1.00 0.39 1.00 1.00 6.00 0.00 1.00 0.31 1.00 1.00 10.00 0.00 1.00 0.00 1.00 1.00 Table A.2b-18. Proposed HSC curve for Dolly Varden juvenile rearing, velocity. Velocity Baldrige Cooper Cr WDFW Falls Cr Proposed 0.00 1.00 0.10 0.25 0.50 0.50 0.16 1.00 0.82 0.46 1.00 0.90 0.20 1.00 1.00 0.51 1.00 1.00 0.35 1.00 1.00 0.70 1.00 1.00 0.40 1.00 1.00 0.95 1.00 1.00 0.45 0.90 1.00 1.00 1.00 1.00 0.50 0.80 1.00 1.00 1.00 1.00 0.55 0.78 1.00 1.00 1.00 1.00 0.95 0.60 1.00 0.65 1.00 1.00 1.00 0.60 1.00 0.64 1.00 1.00 1.50 0.40 0.75 0.56 0.30 0.75 2.00 0.20 0.50 0.47 0.20 0.50 2.50 0.05 0.25 0.39 0.10 0.25 3.00 0.00 0.00 0.31 0.00 0.00 3.15 0.00 0.00 0.28 0.00 0.00 3.45 0.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 20 June 2014 Figure A.2b-19. Proposed HSC curve for Dolly Varden fry rearing, depth. Figure A.2b-20. Proposed HSC curve for Dolly Varden fry rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 21 June 2014 Table A.2b-19. Proposed HSC curve for Dolly Varden fry rearing, depth. Depth Baldrige Cooper Cr Falls Cr Proposed 0.00 0.00 0.00 0.00 0.00 0.05 1.00 0.00 0.25 0.25 0.10 1.00 0.00 0.50 0.50 0.20 1.00 0.50 1.00 1.00 0.30 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.50 0.80 1.00 1.00 1.00 2.00 0.60 1.00 1.00 1.00 2.50 0.40 1.00 1.00 1.00 3.50 0.20 1.00 1.00 1.00 4.00 0.10 1.00 1.00 1.00 5.00 0.00 1.00 1.00 1.00 Table A.2b-20. Proposed HSC curve for Dolly Varden fry rearing, velocity. Velocity Baldrige Cooper Cr Falls Cr Proposed 0.00 1.00 1.00 1.00 1.00 0.15 1.00 1.00 1.00 1.00 0.20 1.00 0.80 1.00 1.00 0.30 0.93 0.40 1.00 0.93 0.36 0.89 0.38 1.00 0.89 0.50 0.80 0.33 0.80 0.80 1.50 0.20 0.00 0.20 0.20 2.00 0.05 0.00 0.10 0.10 2.50 0.00 0.00 0.00 0.00 3.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 22 June 2014 Figure A.2b-21. Proposed HSC curve for Dolly Varden adult rearing, depth. Figure A.2b-22. Proposed HSC curve for Dolly Varden adult rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 23 June 2014 Table A.2b-21. Proposed HSC curve for Dolly Varden adult rearing, depth. Depth Cooper Cr Falls Cr Proposed 0.00 0.00 0.00 0.00 0.30 0.00 0.00 0.00 0.50 0.00 0.17 0.14 1.50 0.67 1.00 0.83 1.75 0.83 1.00 1.00 2.00 1.00 1.00 1.00 7.00 1.00 1.00 1.00 Table A.2b-22. Proposed HSC curve for Dolly Varden adult rearing, velocity. Velocity Cooper Cr Falls Cr Proposed 0.00 0.10 0.50 0.10 0.16 0.82 1.00 0.82 0.20 1.00 1.00 1.00 1.50 1.00 1.00 1.00 1.75 1.00 0.20 1.00 2.00 1.00 0.13 1.00 2.50 0.55 0.00 0.55 3.00 0.10 0.00 0.10 4.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 24 June 2014 Figure A.2b-23. Proposed HSC curve for rainbow trout spawning, depth. Figure A.2b-24. Proposed HSC curve for rainbow trout spawning, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 25 June 2014 Table A.2b-23. Proposed HSC curve for rainbow trout spawning, depth. Depth Cooper Cr WDFW-SH WDFW-RB Proposed 0.00 0.00 0.00 0.00 0.00 0.15 0.00 0.00 0.00 0.00 0.20 0.00 0.00 0.08 0.00 0.35 0.19 0.00 0.30 0.19 0.45 0.31 0.00 0.85 0.31 0.55 0.44 0.00 1.00 0.44 0.65 0.56 0.00 1.00 0.56 0.75 0.69 0.40 1.00 0.69 0.95 0.94 0.65 1.00 0.94 1.00 1.00 0.71 0.90 1.00 1.15 1.00 0.90 0.60 1.00 1.35 1.00 1.00 0.60 1.00 1.45 1.00 1.00 0.25 1.00 2.35 1.00 0.80 0.25 1.00 2.65 1.00 0.30 0.25 1.00 2.95 1.00 0.20 0.25 1.00 5.00 1.00 0.20 0.25 1.00 6.00 1.00 0.16 0.20 1.00 10.00 1.00 0.00 0.00 1.00 Table A.2b-24. Proposed HSC curve for rainbow trout spawning, velocity. Velocity Cooper Cr WDFW-SH WDFW-RB Proposed 0.00 0.00 0.00 0.00 0.00 0.15 0.15 0.00 0.00 0.15 0.20 0.20 0.05 0.00 0.20 0.25 0.33 0.10 0.00 0.33 0.50 1.00 0.16 0.19 1.00 0.65 1.00 0.20 0.30 1.00 1.05 1.00 0.30 0.40 1.00 1.15 1.00 0.75 0.43 1.00 1.25 1.00 0.83 0.45 1.00 1.45 1.00 1.00 0.73 1.00 1.65 1.00 1.00 1.00 1.00 1.95 1.00 1.00 1.00 1.00 2.15 1.00 1.00 0.91 1.00 2.50 1.00 0.93 0.76 1.00 2.65 0.90 0.90 0.69 0.90 2.75 0.83 0.87 0.65 0.83 2.95 0.70 0.80 0.00 0.70 3.25 0.50 0.70 0.00 0.50 3.45 0.37 0.33 0.00 0.37 4.00 0.00 0.21 0.00 0.00 5.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 26 June 2014 Figure A.2b-25. Proposed HSC curve for rainbow trout juvenile rearing, depth. Figure A.2b-26. Proposed HSC curve for rainbow trout juvenile rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 27 June 2014 Table A.2b-25. Proposed HSC curve for rainbow trout juvenile rearing, depth. Depth Cooper Cr WDFW Sawmill-SH Proposed 0.00 0.00 0.00 0.00 0.00 0.15 0.00 0.00 0.03 0.00 0.20 0.00 0.04 0.04 0.04 0.30 1.00 0.11 0.06 0.28 0.35 1.00 0.15 0.07 0.40 0.40 1.00 0.16 0.08 0.52 0.50 1.00 0.18 0.29 0.76 0.60 1.00 0.20 0.50 1.00 0.65 1.00 0.21 0.60 1.00 0.70 1.00 0.27 0.70 1.00 0.85 1.00 0.44 1.00 1.00 1.25 1.00 0.90 1.00 1.00 1.45 1.00 1.00 1.00 1.00 1.95 1.00 1.00 1.00 1.00 2.15 1.00 0.95 1.00 1.00 2.55 1.00 0.53 1.00 1.00 5.00 1.00 0.53 1.00 1.00 6.00 1.00 0.42 1.00 1.00 10.00 1.00 0.00 1.00 1.00 Table A.2b-26. Proposed HSC curve for rainbow trout juvenile rearing, velocity. Velocity Cooper Cr WDFW Sawmill-SH Proposed 0.00 0.10 0.60 0.00 0.00 0.15 0.78 0.80 0.75 0.75 0.20 1.00 0.82 0.88 0.88 0.25 1.00 0.83 1.00 1.00 0.50 1.00 0.92 1.00 1.00 0.60 1.00 0.95 0.95 1.00 0.75 1.00 1.00 0.86 1.00 0.95 1.00 1.00 0.77 1.00 1.00 1.00 0.96 0.75 1.00 1.15 0.40 0.85 0.64 0.64 1.75 0.12 0.38 0.20 0.20 1.80 0.10 0.35 0.18 0.18 2.25 0.06 0.00 0.13 0.13 3.00 0.00 0.00 0.04 0.04 3.25 0.00 0.00 0.00 0.00 5.00 0.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 28 June 2014 Figure A.2b-27. Proposed HSC curve for rainbow trout fry rearing, depth. Figure A.2b-28. Proposed HSC curve for rainbow trout fry rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 29 June 2014 Table A.2b-27. Proposed HSC curve for rainbow trout fry rearing, depth. Depth Cooper Cr Sawmill-SH Proposed 0.00 0.00 0.00 0.00 0.10 0.00 0.67 0.00 0.15 0.25 1.00 0.25 0.30 1.00 1.00 1.00 0.75 1.00 1.00 1.00 3.25 1.00 0.05 1.00 7.00 1.00 0.02 1.00 9.00 1.00 0.00 1.00 Table A.2b-28. Proposed HSC curve for rainbow trout fry rearing, velocity. Velocity Cooper Cr Sawmill-SH Proposed 0.00 1.00 1.00 1.00 0.15 1.00 1.00 1.00 0.25 0.60 0.54 0.60 0.30 0.40 0.48 0.40 0.50 0.33 0.25 0.33 0.95 0.18 0.20 0.25 1.50 0.00 0.15 0.15 1.75 0.00 0.10 0.10 1.80 0.00 0.08 0.08 2.00 0.00 0.00 0.00 5.00 0.00 0.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 30 June 2014 Figure A.2b-29. Proposed HSC curve for rainbow trout adult rearing, depth. Figure A.2b-30. Proposed HSC curve for rainbow trout adult rearing, velocity. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 31 June 2014 Table A.2b-29. Proposed HSC curve for rainbow trout adult rearing, depth. Depth Cooper Cr / Proposed 0.00 0.00 0.50 0.00 2.00 1.00 7.00 1.00 Table A.2b-30. Proposed HSC curve for rainbow trout adult rearing, velocity. Velocity Cooper Cr / Proposed 0.00 0.10 0.20 1.00 2.00 1.00 3.00 0.10 4.00 0.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 2b Page 32 June 2014 Table A.2b-31. Substrate classification and HSC values. Material Size (mm) Spawning Rearing Chinook Coho Sockeye RB/DV All Organic Organic 0.00 0.00 0.00 0.00 1.00 Sand/Silt < 2 0.00 0.00 0.00 0.00 1.00 Small Gravel 2 - 8 0.30 0.40 0.40 0.50 1.00 Med Gravel 8 - 32 1.00 1.00 1.00 1.00 1.00 Large Gravel 32 - 64 1.00 1.00 1.00 1.00 1.00 Small Cobble 64-128 1.00 0.70 0.70 1.00 1.00 Large Cobble 128-256 0.50 0.00 0.00 0.50 1.00 Boulder > 266 0.00 0.00 0.00 0.00 1.00 Bedrock Bedrock 0.00 0.00 0.00 0.00 1.00 Table A.2b-32. Cover classification and HSC values. Type of Cover Fry Juvenile Undercut Bank 1.00 1.00 Overhanging Vegetation 1.00 1.00 Rootwad (including partly undercut) 1.00 1.00 Log Jam/submerged brush pile 1.00 1.00 Logs(s) parallel to bank/rip-rap 0.30 0.80 Aquatic Vegetation 1.00 0.80 Short (<1') terrestrial grass 0.40 0.10 Tall (>3') dense grass 0.70 0.70 Vegetation beyond the bank-full waters edge 0.20 0.20 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 3: Calibration Details FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 This appendix contains the following tables: Table A.3-1. Velocity Adjustment Factors (VAF), original and revised, for T100 and T110. Table A.3-2. Velocity Adjustment Factors (VAF), original and revised, for T120, T130, and T140. Table A.3-3. Velocity Adjustment Factors (VAF), original and revised, for T150 and T160. Table A.3-4. Velocity Adjustment Factors (VAF), original and revised, for T200 and T300. Table A.3-5. Velocity Adjustment Factors (VAF), original and revised, for T220 and T230. Table A.3-6. Velocity Adjustment Factor (VAF), original and revised, for T310 and T330, Main. Table A.3-7. Velocity Adjustment Factors (VAF), original and revised, for T330, Secondary and Tertiary Channels. Table A.3-8. Velocity Adjustment Factors (VAF), original and revised, for T400, T410, and T430. Table A.3-9. Changes to original data decks, Grant Creek. Table A.3-10. Summary of calibration details for original and revised input decks, Grant Creek, Transect 100. Table A.3-11. Summary of calibration details for original and revised input decks, Grant Creek, Transect 100, high flows. Table A.3-12. Summary of calibration details for original and revised input decks, Grant Creek, Transect 110. Table A.3-13. Summary of calibration details for original and revised input decks, Grant Creek, Transect 110, high flows. Table A.3- 14. Summary of calibration details for original and revised input decks, Grant Creek, Transect 120. Table A.3-15. Summary of calibration details for original and revised input decks, Grant Creek, Transect 120, high flows. Table A.3-16. Summary of calibration details for original and revised input decks, Grant Creek, Transect 130. Table A.3-17. Summary of calibration details for original and revised input decks, Grant Creek, Transect 130, high flows. Table A.3-18. Summary of calibration details for original and revised input decks, Grant Creek, Transect 140. Table A.3-19. Summary of calibration details for original and revised input decks, Grant Creek, Transect 140, high flows. Table A.3-20. Summary of calibration details for original and revised input decks, Grant Creek, Transect 150. Table A.3-21. Summary of calibration details for original and revised input decks, Grant Creek, Transect 150, high flows. Table A.3-22. Summary of calibration details for original and revised input decks, Grant Creek, Transect 160. Table A.3-23. Summary of calibration details for original and revised input decks, Grant Creek, Transect T160, high flows. Table A.3-24. Summary of calibration details for original and revised input decks, Grant Creek, Transect 200. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Table A.3-25. Summary of calibration details for original and revised input decks, Grant Creek, Transect 200, high flows. Table A.3-26. Summary of calibration details for original and revised input decks, Grant Creek, Transect 210. Table A.3-27. Summary of calibration details for original and revised input decks, Grant Creek, Transect 220. Table A.3-28. Summary of calibration details for original and revised input decks, Grant Creek, Transect 220, high flows. Table A.3-29. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, side channel. Table A.3-30. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, main channel. Table A.3-31. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230 main channel, high flows. Table A.3-32. Summary of calibration details for original and revised input decks, Grant Creek, Transect 300. Table A.3-33. Summary of calibration details for original and revised input decks, Grant Creek, Transect 300, high flows. Table A.3-34. Summary of calibration details for original and revised input decks, Grant Creek, Transect 310. Table A.3-35. Summary of calibration details for original and revised input decks, Grant Creek, Transect 310, high flows. Table A.3-36. Summary of calibration details for original and revised input decks, Grant Creek, Transect 320. Table A.3-37. Summary of calibration details for original and revised input decks, Grant Creek, Transect 320, high flows. Table A.3-38. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, secondary channel. Table A.3-39. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, second channel, high flows. Table A.3-40. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, tertiary channel. Table A.3-41. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, tertiary channel, high flows. Table A.3-42. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, main channel. Table A.3-43. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, main channel, high flows. Table A.3-44. Summary of calibration details for original and revised input decks, Grant Creek, Transect 400. Table A.3-45. Summary of calibration details for original and revised input decks, Grant Creek, Transect 400, high flows. Table A.3-46. Summary of calibration details for original and revised input decks, Grant Creek, Transect 410. Table A.3-47. Summary of calibration details for original and revised input decks, Grant Creek, Transect 410, high flows. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Table A.3-48. Summary of calibration details for original and revised input decks, Grant Creek, Transect 430. Table A.3-49. Summary of calibration details for original and revised input decks, Grant Creek, Transect 430, high flows. Table A.3-50. Summary of calibration details, Grant Creek. Table A.3-51. Summary of calibration details, Grant Creek. Table A.3-52. Summary of calibration details, Grant Creek. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 1 June 2014 Table A.3-1. Velocity Adjustment Factors (VAF), original and revised, for T100 and T110. Flow (cfs) T100 T110 Orig Rev 1V Depth Orig Rev 1V Depth 0.10 0.8797 0.8797 1.5192 1.5192 0.20 1.0328 1.0327 1.3787 1.3787 0.30 1.1118 1.1114 1.2772 1.2772 0.40 1.1556 1.1551 1.2156 1.2156 0.50 1.1868 1.1861 1.1758 1.1758 0.60 1.2114 1.2104 1.1480 1.1480 0.70 1.2282 1.2270 1.1273 1.1273 0.80 1.2396 1.2382 1.1074 1.1084 0.90 1.2471 1.2456 1.0905 1.0933 1.00 1.2520 1.2503 1.0762 1.0808 1.09 1.2553 1.2535 1.0651 1.0714 1.19 1.2580 1.2560 1.0543 1.0624 1.29 1.2599 1.2576 1.0450 1.0548 1.39 1.2564 1.2540 1.0367 1.0482 1.49 1.2512 1.2486 1.0295 1.0425 1.59 1.2453 1.2425 1.0231 1.0375 1.69 1.2390 1.2360 1.0171 1.0331 1.79 1.2327 1.2294 1.0114 1.0290 1.89 1.2257 1.2222 1.0062 1.0253 1.99 1.2170 1.2133 0.4715 1.0015 1.0221 0.2325 2.24 1.1986 1.1877 0.4579 0.9914 1.0128 0.2292 2.49 1.1826 1.1781 0.4462 0.9825 1.0095 0.2264 2.74 1.1669 1.1607 0.4345 0.9750 1.0047 0.2241 2.99 1.1531 1.1452 0.4242 0.9687 1.0008 0.2221 3.23 1.1415 1.1323 0.4157 0.9634 0.9976 0.2204 3.48 1.1308 1.1203 0.4074 0.9586 0.9949 0.2189 3.73 1.1213 1.1098 0.4002 0.9545 0.9926 0.2176 3.98 1.1129 1.1006 0.3938 0.9509 0.9905 0.2164 4.48 1.0985 1.0845 0.3832 0.9448 0.9865 0.2142 4.98 1.0866 1.0700 0.3746 0.9400 0.9827 0.2121 5.47 1.0772 1.0576 0.3677 0.9361 0.9793 0.2102 5.97 1.0695 1.0467 0.3619 0.9329 0.9758 0.2084 6.47 1.0631 1.0372 0.3570 0.9302 0.9722 0.2067 6.97 1.0576 1.0281 0.3523 0.9280 0.9685 0.2050 7.46 1.0530 1.0194 0.3479 0.9261 0.9648 0.2035 7.96 1.0490 1.0111 0.3437 0.9245 0.9610 0.2020 8.46 1.0457 1.0033 0.3398 0.9231 0.9574 0.2007 8.96 1.0430 0.9960 0.3362 0.9219 0.9539 0.1994 9.46 1.0406 0.9892 0.3328 0.9206 0.9500 0.1980 9.95 1.0385 0.9827 0.3296 0.9196 0.9462 0.1966 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 2 June 2014 Table A.3-2. Velocity Adjustment Factors (VAF), original and revised, for T120, T130, and T140. Flow (cfs) T120 T130 T140 Orig Rev 1V Depth Orig Rev 1V Depth Orig Rev 1V Depth 10 0.2078 0.2078 0.4185 0.4185 0.6020 0.6021 20 0.3195 0.3195 0.5610 0.5610 0.7870 0.7921 30 0.4015 0.4015 0.6564 0.6564 0.8795 0.8940 40 0.4684 0.4684 0.7293 0.7293 0.9394 0.9656 50 0.5252 0.5253 0.7881 0.7881 0.9722 1.0140 60 0.5746 0.5750 0.8377 0.8377 0.9958 1.0540 70 0.6188 0.6197 0.8809 0.8809 1.0109 1.0866 80 0.6588 0.6605 0.9194 0.9194 1.0195 1.1104 90 0.6956 0.6983 0.9541 0.9541 1.0239 1.1280 100 0.7297 0.7335 0.9858 0.9858 1.0241 1.1396 110 0.7616 0.7667 1.0151 1.0151 1.0181 1.1420 120 0.7916 0.7979 1.0422 1.0422 1.0095 1.1396 130 0.8198 0.8275 1.0671 1.0671 0.9963 1.1298 140 0.8466 0.8559 1.0893 1.0893 0.9829 1.1184 150 0.8723 0.8831 1.1084 1.1084 0.9696 1.1061 160 0.8970 0.9092 1.1241 1.1241 0.9570 1.0939 170 0.9209 0.9345 1.1368 1.1368 0.9451 1.0819 180 0.9437 0.9588 1.1471 1.1471 0.9341 1.0704 190 0.9659 0.9824 1.1553 1.1555 0.9240 1.0595 200 0.9874 1.0053 0.8831 1.1620 1.1625 1.2983 0.9146 1.0490 3.3867 225 1.0388 1.0596 0.9276 1.1743 1.1752 1.3026 0.8941 1.0231 3.3228 250 1.0872 1.1106 0.9690 1.1808 1.1820 1.3023 0.8774 1.0006 3.2674 275 1.1331 1.1586 1.0073 1.1833 1.1847 1.2991 0.8636 0.9815 3.2204 300 1.1770 1.2043 1.0435 1.1837 1.1852 1.2947 0.8522 0.9653 3.1786 325 1.2190 1.2479 1.0780 1.1832 1.1847 1.2901 0.8426 0.9514 3.1381 350 1.2594 1.2897 1.1108 1.1822 1.1838 1.2858 0.8345 0.9394 3.1005 375 1.2984 1.3300 1.1423 1.1810 1.1826 1.2817 0.8276 0.9290 3.0662 400 1.3362 1.3689 1.1727 1.1798 1.1814 1.2781 0.8217 0.9199 3.0349 450 1.4084 1.4432 1.2292 1.1764 1.1780 1.2709 0.8123 0.9051 2.9812 497 1.4728 1.5093 1.2813 1.1706 1.1722 1.2629 0.8056 0.8941 2.9363 546 1.5369 1.5750 1.3308 1.1641 1.1656 1.2549 0.8004 0.8850 2.8985 591 1.5934 1.6328 1.3771 1.1581 1.1596 1.2481 0.7966 0.8782 2.8671 638 1.6504 1.6908 1.4224 1.1516 1.1530 1.2411 0.7937 0.8724 2.8395 685 1.7053 1.7469 1.4660 1.1447 1.1461 1.2341 0.7914 0.8677 2.8148 732 1.7586 1.8011 1.5081 1.1380 1.1394 1.2276 0.7897 0.8638 2.7923 779 1.8103 1.8537 1.5487 1.1312 1.1325 1.2209 0.7884 0.8606 2.7704 826 1.8605 1.9047 1.5872 1.1248 1.1261 1.2146 0.7875 0.8579 2.7511 873 1.9095 1.9544 1.6255 1.1190 1.1202 1.2090 0.7870 0.8557 2.7329 920 1.9573 2.0029 1.6626 1.1136 1.1148 1.2040 0.7867 0.8538 2.7156 967 2.0039 2.0502 1.6988 1.1088 1.1099 1.1995 0.7866 0.8523 2.6998 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 3 June 2014 Table A.3-3. Velocity Adjustment Factors (VAF), original and revised, for T150 and T160. Flow (cfs) T150 T160 Orig Rev 1V Depth Orig Rev 1V Depth 10 0.4628 0.4626 0.2103 0.2083 20 0.6124 0.6116 0.3170 0.3179 30 0.7003 0.6990 0.3987 0.4023 40 0.7609 0.7591 0.4664 0.4723 50 0.8068 0.8047 0.5248 0.5329 60 0.8420 0.8397 0.5745 0.5852 70 0.8694 0.8671 0.6180 0.6310 80 0.8889 0.8863 0.6567 0.6719 90 0.9050 0.9024 0.6905 0.7082 100 0.9187 0.9161 0.7214 0.7409 110 0.9305 0.9280 0.7497 0.7710 120 0.9382 0.9364 0.7762 0.7988 130 0.9451 0.9440 0.8009 0.8248 140 0.9515 0.9510 0.8243 0.8493 150 0.9575 0.9575 0.8465 0.8726 160 0.9632 0.9637 0.8676 0.8946 170 0.9686 0.9696 0.8878 0.9157 180 0.9737 0.9752 0.9069 0.9358 190 0.9787 0.9806 0.9252 0.9550 200 0.9835 0.9859 2.0941 0.9426 0.9733 1.2472 225 0.9949 0.9983 2.1285 0.9834 1.0160 1.3055 250 1.0057 1.0099 2.1593 1.0210 1.0551 1.3588 275 1.0159 1.0208 2.1868 1.0558 1.0912 1.4080 300 1.0257 1.0312 2.2117 1.0885 1.1250 1.4537 325 1.0350 1.0410 2.2346 1.1194 1.1569 1.4968 350 1.0441 1.0505 2.2559 1.1488 1.1871 1.5376 375 1.0528 1.0596 2.2759 1.1769 1.2159 1.5764 400 1.0612 1.0684 2.2947 1.2038 1.2435 1.6135 450 1.0773 1.0850 2.3275 1.2547 1.2955 1.6819 497 1.0916 1.0995 2.3532 1.2995 1.3411 1.7443 546 1.1057 1.1136 2.3744 1.3436 1.3858 1.8028 591 1.1180 1.1258 2.3913 1.3820 1.4247 1.8571 638 1.1303 1.1379 2.4064 1.4204 1.4636 1.9098 685 1.1421 1.1494 2.4198 1.4572 1.5007 1.9601 732 1.1535 1.1604 2.4310 1.4926 1.5363 2.0083 779 1.1644 1.1709 2.4404 1.5267 1.5706 2.0547 826 1.1749 1.1810 2.4485 1.5596 1.6037 2.0984 873 1.1851 1.1907 2.4560 1.5915 1.6357 2.1415 920 1.1949 1.2000 2.4621 1.6224 1.6667 2.1833 967 1.2045 1.2089 2.4671 1.6523 1.6966 2.2233 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 4 June 2014 Table A.3-4. Velocity Adjustment Factors (VAF), original and revised, for T200 and T300. Flow (cfs) T200 T300 Orig Rev 1V Depth Flow (cfs) Orig Rev 1V Depth 0.89 0.7584 0.7159 0.17 0.5388 0.5388 1.79 0.7828 0.7485 0.34 0.5726 0.5726 2.68 0.8155 0.7841 0.51 0.6109 0.6109 3.57 0.8498 0.8195 0.68 0.6462 0.6462 4.47 0.8833 0.8536 0.85 0.6780 0.6780 5.36 0.9126 0.8832 1.02 0.7065 0.7065 6.26 0.9412 0.9120 1.19 0.7321 0.7321 7.15 0.9681 0.9389 1.36 0.7551 0.7551 8.04 0.9934 0.9642 1.53 0.7760 0.7760 8.94 1.0174 0.9882 1.71 0.7962 0.7962 9.83 1.0402 1.0108 1.88 0.8138 0.8138 10.72 1.0620 1.0326 2.05 0.8303 0.8303 11.62 1.0832 1.0537 2.22 0.8459 0.8459 12.51 1.1035 1.0737 2.39 0.8606 0.8606 13.40 1.1230 1.0931 2.56 0.8747 0.8747 14.30 1.1422 1.1111 2.73 0.8881 0.8881 15.19 1.1606 1.1282 2.90 0.9010 0.9010 16.08 1.1786 1.1446 3.07 0.9135 0.9135 16.98 1.1963 1.1605 3.24 0.9254 0.9254 17.87 1.2134 1.1750 0.0829 3.41 0.9370 0.9370 0.0220 20.11 1.2548 1.2082 0.0851 3.84 0.9648 0.9648 0.0225 22.34 1.2940 1.2363 0.0872 4.26 0.9902 0.9902 0.0230 24.57 1.3316 1.2606 0.0891 4.69 1.0146 1.0146 0.0234 26.81 1.3678 1.2819 0.0910 5.12 1.0375 1.0375 0.0239 29.04 1.4025 1.2998 0.0927 5.54 1.0587 1.0587 0.0243 31.28 1.4363 1.3134 0.0943 5.97 1.0795 1.0795 0.0247 33.51 1.4689 1.3258 0.0959 6.40 1.0993 1.0993 0.0250 35.74 1.5004 1.3371 0.0973 6.82 1.1179 1.1179 0.0254 40.21 1.5609 1.3576 0.1002 7.67 1.1536 1.1536 0.0260 44.68 1.6182 1.3763 0.1028 8.53 1.1874 1.1874 0.0267 49.15 1.6726 1.3938 0.1053 9.38 1.2188 1.2188 0.0273 53.61 1.7246 1.4104 0.1077 10.23 1.2485 1.2485 0.0278 58.08 1.7744 1.4264 0.1100 11.09 1.2770 1.2770 0.0283 62.55 1.8223 1.4419 0.1122 11.94 1.3037 1.3037 0.0288 67.02 1.8685 1.4569 0.1143 12.79 1.3292 1.3292 0.0293 71.49 1.9132 1.4716 0.1164 13.64 1.3537 1.3537 0.0297 75.95 1.9563 1.4859 0.1184 14.50 1.3776 1.3776 0.0302 80.42 1.9983 1.4992 0.1203 15.35 1.4003 1.4003 0.0306 84.89 2.0391 1.5121 0.1221 16.20 1.4222 1.4222 0.0310 89.36 2.0788 1.5248 0.1239 17.06 1.4436 1.4436 0.0314 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 5 June 2014 Table A.3-5. Velocity Adjustment Factors (VAF), original and revised, for T220 and T230. Flow (cfs) T220 T230 Orig Rev 1V Depth Orig Rev 1V Depth 10 0.3592 0.3592 0.6917 0.2325 20 0.5091 0.5091 0.8112 0.3487 30 0.6111 0.6111 0.8749 0.4374 40 0.6876 0.6876 0.9180 0.5117 50 0.7497 0.7497 0.9506 0.5767 60 0.8026 0.8025 0.9767 0.6351 70 0.8489 0.8489 0.9985 0.6884 80 0.8904 0.8903 1.0173 0.7378 90 0.9275 0.9274 1.0338 0.7840 100 0.9615 0.9614 1.0484 0.8274 110 0.9927 0.9925 1.0616 0.8686 120 1.0216 1.0215 1.0736 0.9078 130 1.0488 1.0486 1.0847 0.9452 140 1.0742 1.0740 1.0949 0.9811 150 1.0984 1.0981 1.1044 1.0155 160 1.1209 1.1207 1.1133 1.0486 170 1.1419 1.1416 1.1217 1.0805 180 1.1618 1.1614 1.1296 1.1114 190 1.1807 1.1804 1.1371 1.1414 200 1.2019 1.2016 2.2476 1.1442 1.1703 1.3622 225 1.2443 1.2439 2.3169 1.1605 1.2389 1.4308 250 1.2830 1.2825 2.3802 1.1752 1.3030 1.4929 275 1.3187 1.3182 2.4388 1.1885 1.3633 1.5500 300 1.3520 1.3514 2.4933 1.2007 1.4204 1.6031 325 1.3832 1.3826 2.5446 1.2119 1.4748 1.6528 350 1.4127 1.4120 2.5931 1.2224 1.5268 1.6997 375 1.4407 1.4399 2.6391 1.2322 1.5767 1.7442 400 1.4673 1.4665 2.6830 1.2413 1.6246 1.7865 450 1.5171 1.5163 2.7652 1.2581 1.7155 1.8659 500 1.5632 1.5622 2.8413 1.2733 1.8007 1.9391 550 1.6060 1.6050 2.9124 1.2871 1.8812 2.0074 600 1.6462 1.6451 2.9792 1.2997 1.9575 2.0717 650 1.6842 1.6830 3.0424 1.3114 2.0303 2.1326 700 1.7202 1.7189 3.1023 1.3223 2.0999 2.1904 750 1.7544 1.7531 3.1595 1.3325 2.1668 2.2457 800 1.7872 1.7858 3.2142 1.3421 2.2311 2.2986 850 1.8186 1.8171 3.2667 1.3511 2.2932 2.3494 900 1.8487 1.8472 3.3171 1.3597 2.3533 2.3983 950 1.8777 1.8762 3.3658 1.3678 2.4115 2.4455 1000 1.9057 1.9042 3.4128 1.3756 2.4680 2.4911 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 6 June 2014 Table A.3-6. Velocity Adjustment Factor (VAF), original and revised, for T310 and T330, Main. T310 T330-MC Flow (cfs) Orig Rev 1V Depth Flow (cfs) Orig Rev 1V Depth 8.42 0.2676 0.2676 1.51 0.3384 0.3296 16.84 0.3536 0.3536 3.01 0.4659 0.4534 25.26 0.4196 0.4196 4.52 0.5433 0.5285 33.67 0.4757 0.4757 6.03 0.5980 0.5815 42.90 0.5297 0.5252 7.53 0.6395 0.6219 50.51 0.5702 0.5702 9.04 0.6733 0.6546 58.93 0.6117 0.6117 10.54 0.7012 0.6817 67.35 0.6504 0.6505 12.05 0.7252 0.7050 75.77 0.6868 0.6870 13.56 0.7460 0.7252 84.19 0.7214 0.7216 15.06 0.7640 0.7427 92.60 0.7543 0.7545 16.57 0.7802 0.7583 101.20 0.7865 0.7861 18.08 0.7947 0.7723 109.44 0.8161 0.8165 19.58 0.8078 0.7849 117.86 0.8453 0.8457 21.09 0.8198 0.7964 126.28 0.8736 0.8740 22.60 0.8308 0.8069 134.70 0.9009 0.9015 24.10 0.8410 0.8165 143.12 0.9275 0.9281 25.61 0.8505 0.8255 151.54 0.9533 0.9541 27.12 0.8594 0.8337 159.95 0.9785 0.9793 28.62 0.8677 0.8414 168.37 1.0030 1.0040 0.9164 30.13 0.8756 0.8484 0.5800 189.42 1.0620 1.0635 0.9573 33.89 0.8933 0.8643 0.5789 210.47 1.1181 1.1200 0.9959 37.66 0.9091 0.8782 0.5771 231.51 1.1715 1.1740 1.0325 41.43 0.9232 0.8904 0.5747 252.56 1.2228 1.2258 1.0674 45.19 0.9359 0.9012 0.5718 273.61 1.2721 1.2757 1.1008 48.96 0.9475 0.9109 0.5687 294.65 1.3196 1.3239 1.1329 52.72 0.9582 0.9197 0.5655 315.70 1.3656 1.3705 1.1639 56.49 0.9681 0.9277 0.5621 336.75 1.4102 1.4158 1.1937 60.26 0.9773 0.9350 0.5587 378.84 1.4958 1.5028 1.2506 67.79 0.9940 0.9480 0.5520 420.93 1.5770 1.5855 1.3044 75.32 1.0088 0.9593 0.5456 463.02 1.6546 1.6646 1.3555 82.85 1.0222 0.9693 0.5397 505.12 1.7290 1.7405 1.4044 90.38 1.0343 0.9782 0.5343 547.21 1.8005 1.8135 1.4512 97.92 1.0455 0.9863 0.5294 589.30 1.8696 1.8841 1.4963 105.45 1.0558 0.9934 0.5238 631.40 1.9365 1.9525 1.5398 112.98 1.0653 0.9999 0.5188 673.49 2.0013 2.0188 1.5820 120.51 1.0742 1.0059 0.5143 715.58 2.0643 2.0833 1.6228 128.05 1.0826 1.0116 0.5102 757.68 2.1257 2.1461 1.6624 135.58 1.0905 1.0169 0.5065 799.77 2.1855 2.2074 1.7010 143.11 1.0979 1.0219 0.5031 841.86 2.2438 2.2673 1.7384 150.64 1.1050 1.0266 0.5000 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 7 June 2014 Table A.3-7. Velocity Adjustment Factors (VAF), original and revised, for T330, Secondary and Tertiary Channels. T330-2C T330-3C Flow (cfs) Orig Rev 1V Depth Flow (cfs) Orig Rev 1V Depth 0.13 0.2014 0.2015 0.03 0.0573 0.1370 0.25 0.2629 0.2630 0.07 0.1269 0.3049 0.38 0.3102 0.3104 0.10 0.1736 0.4184 0.51 0.3485 0.3487 0.13 0.2155 0.5213 0.64 0.3812 0.3814 0.16 0.2530 0.6139 0.76 0.4082 0.4083 0.20 0.2966 0.7224 0.89 0.4347 0.4347 0.23 0.3250 0.7933 1.02 0.4590 0.4591 0.26 0.3499 0.8560 1.15 0.4816 0.4816 0.30 0.3784 0.9277 1.27 0.5012 0.5012 0.33 0.3966 0.9736 1.40 0.5213 0.5213 0.36 0.4124 1.0132 1.53 0.5398 0.5401 0.40 0.4300 1.0575 1.65 0.5559 0.5566 0.43 0.4410 1.0848 1.78 0.5727 0.5736 0.46 0.4503 1.1078 1.91 0.5887 0.5899 0.49 0.4580 1.1267 2.04 0.6041 0.6056 0.53 0.4662 1.1464 2.16 0.6178 0.6195 0.56 0.4709 1.1576 2.29 0.6322 0.6347 0.59 0.4745 1.1658 2.42 0.6461 0.6481 0.63 0.4777 1.1731 2.54 0.6584 0.6606 0.2792 0.66 0.4791 1.1759 0.3555 2.86 0.6896 0.6925 0.2911 0.74 0.4787 1.1731 0.3598 3.18 0.7179 0.7217 0.3020 0.82 0.4737 1.1594 0.3605 3.50 0.7437 0.7487 0.3120 0.91 0.4641 1.1351 0.3583 3.82 0.7678 0.7740 0.3214 0.99 0.4521 1.1085 0.3542 4.14 0.7904 0.7979 0.3303 1.07 0.4366 1.0787 0.3488 4.45 0.8110 0.8199 0.3384 1.15 0.4209 1.0470 0.3424 4.77 0.8313 0.8416 0.3464 1.24 0.4032 1.0102 0.3343 5.73 0.8867 0.8623 0.3541 1.32 0.3876 0.9772 0.3267 5.90 0.8958 0.9010 0.3685 1.37 0.3791 0.9121 0.3108 6.36 0.9195 0.9354 0.3816 1.48 0.3579 0.8452 0.2934 7.00 0.9505 0.9678 0.3941 1.81 0.3034 0.7851 0.2770 7.63 0.9785 0.9976 0.4056 1.98 0.2796 0.7222 0.2595 8.27 1.0048 1.0257 0.4165 2.14 0.2597 0.6574 0.2417 8.91 1.0297 1.0523 0.4269 2.31 0.2409 0.5910 0.2228 9.54 1.0529 1.0773 0.4367 2.47 0.2251 0.5343 0.2058 10.18 1.0753 1.1015 0.4463 2.64 0.2100 0.4810 0.1888 10.82 1.0968 1.1247 0.4554 2.80 0.1972 0.4278 0.1710 11.45 1.1171 1.1466 0.4641 2.97 0.1850 0.3814 0.1550 12.09 1.1369 1.1680 0.4726 3.13 0.1746 0.3450 0.1419 12.72 1.1558 1.1884 0.4807 3.30 0.1640 0.3108 0.1296 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 8 June 2014 Table A.3-8. Velocity Adjustment Factors (VAF), original and revised, for T400, T410, and T430. Flow (cfs) T400 T410 T430 Orig Rev 1V Depth Orig Rev 1V Depth Orig Rev 1V Depth 10 0.2620 0.2645 0.8073 0.8112 0.2099 0.2099 20 0.3531 0.3573 0.9298 0.9382 0.3408 0.3408 30 0.4199 0.4255 0.9985 1.0111 0.4400 0.4400 40 0.4733 0.4800 1.0348 1.0503 0.5206 0.5206 50 0.5199 0.5274 1.0322 1.0522 0.5887 0.5887 60 0.5614 0.5699 1.0245 1.0458 0.6475 0.6475 70 0.5993 0.6085 1.0206 1.0430 0.6993 0.6993 80 0.6337 0.6437 1.0192 1.0426 0.7454 0.7454 90 0.6657 0.6764 1.0194 1.0438 0.7868 0.7868 100 0.6956 0.7070 1.0198 1.0453 0.8244 0.8244 110 0.7233 0.7358 1.0192 1.0465 0.8585 0.8585 120 0.7491 0.7620 1.0189 1.0471 0.8890 0.8889 130 0.7734 0.7870 1.0193 1.0486 0.9165 0.9164 140 0.7968 0.8108 1.0204 1.0507 0.9416 0.9414 150 0.8192 0.8337 1.0220 1.0533 0.9647 0.9645 160 0.8406 0.8558 1.0241 1.0563 0.9856 0.9857 170 0.8609 0.8765 1.0262 1.0596 1.0049 1.0053 180 0.8806 0.8965 1.0287 1.0632 1.0229 1.0236 190 0.8997 0.9160 1.0314 1.0669 1.0396 1.0406 200 0.9180 0.9347 2.2569 1.0343 1.0707 1.8494 1.0552 1.0561 1.6095 225 0.9614 0.9790 2.3662 1.0375 1.0772 1.8700 1.0903 1.0908 1.6519 250 1.0021 1.0203 2.4678 1.0428 1.0837 1.8811 1.1207 1.1209 1.6872 275 1.0407 1.0594 2.5631 1.0496 1.0915 1.8862 1.1475 1.1473 1.7170 300 1.0776 1.0966 2.6535 1.0572 1.1000 1.8867 1.1714 1.1707 1.7424 325 1.1130 1.1323 2.7396 1.0653 1.1088 1.8845 1.1928 1.1916 1.7641 350 1.1471 1.1667 2.8223 1.0737 1.1179 1.8806 1.2122 1.2105 1.7829 375 1.1801 1.2000 2.9020 1.0824 1.1272 1.8764 1.2299 1.2277 1.7995 400 1.2122 1.2322 2.9791 1.0913 1.1366 1.8720 1.2461 1.2434 1.8137 450 1.2737 1.2941 3.1266 1.1091 1.1554 1.8634 1.2748 1.2711 1.8369 500 1.3324 1.3530 3.2666 1.1270 1.1742 1.8556 1.2996 1.2949 1.8554 550 1.3885 1.4093 3.4003 1.1446 1.1926 1.8490 1.3215 1.3159 1.8705 600 1.4426 1.4636 3.5287 1.1620 1.2108 1.8434 1.3410 1.3346 1.8833 650 1.4948 1.5159 3.6526 1.1791 1.2285 1.8390 1.3587 1.3514 1.8943 700 1.5453 1.5666 3.7723 1.1958 1.2459 1.8352 1.3748 1.3665 1.9032 750 1.5944 1.6159 3.8885 1.2121 1.2629 1.8321 1.3896 1.3803 1.9110 800 1.6422 1.6637 4.0014 1.2281 1.2795 1.8301 1.4033 1.3931 1.9179 850 1.6887 1.7104 4.1114 1.2437 1.2957 1.8287 1.4161 1.4049 1.9240 900 1.7342 1.7560 4.2187 1.2589 1.3116 1.8281 1.4280 1.4159 1.9295 950 1.7786 1.8005 4.3236 1.2739 1.3272 1.8284 1.4393 1.4262 1.9345 1000 1.8221 1.8441 4.4262 1.2886 1.3424 1.8293 1.4498 1.4358 1.9391 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 9 June 2014 Table A.3-9. Changes to original data decks, Grant Creek. Middle Flow Manning N Elevation Trans Station Orig Rev Orig Rev Orig Rev Other 120 7.2 -1.7040 -0.4000 69.9 96.57 96.90 72.2 95.89 96.90 86.1 0.2227 0.1500 86.7 96.51 96.86 90.0 96.04 97.04 130 80.4 97.07 97.08 81.9 97.01 97.15 140 13.1 0.3023 0.13 36.6 0.0114 0.015 39.2 0.0082 0.01 41.4 97.21 98.25 43.0 97.53 98.20 90.3 3.3253 0.3 120.0 98.45 98.45 150 1.8 94.68 96.03 4.5 0.0089 0.0100 65.5 1.2671 0.2000 120.0 95.15 95.23 121.7 94.91 95.33 160 11.5 0.00 0.10 95.43 95.44 11.9 0.00 0.10 0.0608 0.1200 13.5 0.00 0.10 0.0608 0.1200 14.0 0.00 0.10 95.43 95.44 15.7 0.00 0.10 95.43 95.44 17.6 0.00 0.10 95.43 95.44 20.2 0.00 0.10 95.43 95.44 22.0 0.00 0.10 95.43 95.44 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 10 June 2014 Middle Flow Manning N Elevation Trans Station Orig Rev Orig Rev Orig Rev Other 220 6.0 0.1783 0.1250 230-MC 2.5 -0.3713 -0.2500 61.5 -1.2458 -0.1500 310 2.1 96.42 96.44 3.1 96.42 96.44 3.9 -0.4277 -0.2000 61.2 -0.6336 -0.1500 400 4.2 93.70 93.97 5.2 93.28 93.96 6.5 92.93 93.95 10.0 2.1653 0.1800 26.0 93.91 93.90 86.6 2.9033 0.2000 87.8 1.5390 0.1000 410 6.5 94.20 95.30 7.0 94.71 95.25 7.7 95.14 95.11 9.9 94.92 95.25 11.0 94.53 95.26 13.5 94.82 95.30 14.1 94.46 95.30 15.0 94.55 95.28 16.5 94.51 95.25 18.0 94.64 95.23 19.5 93.63 95.24 21.0 94.78 95.78 22.5 94.73 95.73 24.0 94.96 95.96 25.5 95.19 95.24 36.0 94.48 95.48 99.3 94.88 95.25 115.2 95.20 95.25 116.5 94.77 95.30 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 11 June 2014 Middle Flow Manning N Elevation Trans Station Orig Rev Orig Rev Orig Rev Other 117.8 94.64 95.35 119.0 94.69 95.40 430 60.9 89.60 89.75 80.7 89.68 89.75 81.5 -0.5542 0.1700 100 7.5 96.76 96.94 8.5 96.57 96.95 9.5 96.60 96.94 11.0 96.70 96.95 18.7 0.4967 0.3000 40.2 2.0161 0.1600 110 9.0 0.00 0.10 0.5866 0.3000 10.0 0.00 0.10 11.0 0.00 0.10 12.0 0.00 0.10 38.0 0.00 0.10 39.0 0.00 0.10 40.0 0.00 0.10 41.0 0.00 0.10 42.0 0.00 0.10 43.0 0.00 0.10 44.0 0.00 0.10 0.2534 0.1200 200 9.0 -3.3253 0.2000 42.0 0.5878 0.4500 300 No changes 210 No changes 230 No changes 320 12.4 0.5568 0.2100 41.6 95.58 96.23 47.0 95.96 96.32 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 12 June 2014 Middle Flow Manning N Elevation Trans Station Orig Rev Orig Rev Orig Rev Other 49.0 95.94 96.23 49.3 -0.5292 0.1400 50.0 95.98 96.25 51.0 96.19 96.25 330-MC 30.1 10.6096 0.8000 30.3 9.8409 0.8000 30.5 10.6096 1.0000 31.2 10.7510 1.0000 32.2 11.5538 1.0000 33.4 11.8336 1.0000 34.3 12.0305 1.0000 35.5 11.2299 1.0000 60.3 4.8380 0.8000 60.7 6.4423 0.8000 61.7 7.2237 0.8000 64.2 6.1714 0.8000 65.2 5.3203 0.8000 330-2nd 90.70 0.00 0.10 91.70 0.00 0.10 92.20 0.00 0.10 0.2534 0.1500 106.20 0.2520 0.1000 96.60 96.49 106.50 96.38 96.51 106.80 96.28 96.55 109.20 96.17 96.65 330-3rd 109.20 96.17 96.65 112.20 95.98 96.55 125.20 95.37 97.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 13 June 2014 Table A.3-10. Summary of calibration details for original and revised input decks, Grant Creek, Transect 100. WSE (ft) 95.93 96.02 96.88 97.46 Disch (cfs) 0.01 0.25 5.9 14.75 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.00 99.25 2 0.10 98.83 3 2.00 98.82 4 4.00 98.55 5 5.50 98.20 6 7.00 97.84 7 7.20 97.10 0.08 0.12 * 8 7.50 96.76 0.04 0.12 0.15 * 9 8.50 96.57 0.07 0.14 0.15 * 10 9.50 96.60 0.07 0.14 0.15 * 11 11.00 96.70 0.05 0.13 0.15 12 11.90 96.99 0.09 0.14 13 12.20 97.13 0.07 0.11 14 13.50 97.16 0.07 0.10 15 15.50 96.92 0.10 0.15 16 16.00 96.52 0.08 0.13 0.15 0.22 17 16.50 96.52 0.08 0.13 0.15 0.22 18 17.50 96.22 0.12 0.20 0.18 0.27 19 17.70 96.92 0.10 0.15 20 18.50 96.92 0.10 0.15 * 21 18.70 95.92 0.01 0.01 0.04 0.06 0.15 0.16 0.25 0.21 0.31 22 19.00 96.42 0.28 0.28 0.28 0.47 0.43 23 19.50 96.12 0.38 0.39 0.38 0.55 0.50 24 20.00 96.22 0.44 0.45 0.44 0.66 0.60 25 20.50 96.32 0.50 0.51 0.50 0.79 0.72 26 21.00 96.17 0.35 0.36 0.35 0.52 0.47 27 21.50 95.82 0.08 0.08 0.15 0.15 0.43 0.45 0.44 0.58 0.52 28 22.00 95.77 0.12 0.12 0.20 0.20 0.50 0.52 0.51 0.67 0.60 29 22.50 95.72 0.13 0.13 0.21 0.21 0.48 0.50 0.49 0.63 0.57 30 23.00 95.72 0.13 0.13 0.20 0.20 0.46 0.48 0.47 0.61 0.55 31 23.50 95.72 0.17 0.17 0.26 0.26 0.60 0.63 0.61 0.79 0.72 32 24.00 95.92 0.03 0.03 0.14 0.14 0.61 0.63 0.62 0.84 0.76 33 24.50 95.72 0.16 0.16 0.25 0.25 0.58 0.61 0.59 0.77 0.69 34 25.00 95.72 0.20 0.20 0.31 0.31 0.71 0.75 0.74 0.95 0.86 35 25.50 95.72 0.17 0.17 0.26 0.26 0.61 0.64 0.62 0.81 0.73 36 26.00 96.02 0.01 0.01 0.57 0.59 0.58 0.80 0.73 37 26.50 96.02 0.01 0.01 0.50 0.52 0.51 0.71 0.64 38 27.00 95.97 0.07 0.07 0.44 0.46 0.45 0.61 0.56 39 27.50 96.07 0.51 0.53 0.52 0.73 0.66 40 28.00 96.22 0.49 0.50 0.49 0.74 0.67 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 14 June 2014 WSE (ft) 95.93 96.02 96.88 97.46 Disch (cfs) 0.01 0.25 5.9 14.75 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 28.50 96.32 0.42 0.43 0.42 0.66 0.60 42 29.00 96.12 0.33 0.34 0.33 0.48 0.44 43 29.80 96.17 0.22 0.23 0.22 0.33 0.30 44 30.60 96.42 0.26 0.26 0.26 0.44 0.40 45 31.40 96.52 0.21 0.21 0.20 0.38 0.35 46 32.20 96.32 0.01 0.01 0.01 0.02 0.01 47 33.00 96.17 0.01 0.01 0.01 0.01 0.01 48 33.80 96.42 0.01 0.01 0.01 0.01 49 34.60 96.32 0.01 0.01 0.01 0.01 50 35.40 96.62 0.01 0.01 0.01 0.02 0.02 51 36.20 96.42 0.10 0.10 0.10 0.17 0.15 52 37.00 96.32 0.20 0.20 0.20 0.32 0.29 53 37.80 96.32 0.28 0.28 0.28 0.44 0.40 54 38.60 96.32 0.37 0.38 0.37 0.59 0.53 55 39.40 96.32 0.33 0.34 0.33 0.52 0.47 * 56 40.20 96.52 0.02 0.02 0.24 0.04 0.42 57 41.00 96.72 0.01 0.14 0.03 0.36 58 42.00 96.72 0.01 0.14 0.03 0.36 59 43.00 96.77 0.11 0.03 0.34 60 43.50 96.92 0.03 0.29 61 45.00 97.19 0.02 0.18 62 47.00 97.45 0.00 0.02 63 49.00 97.74 64 51.00 98.06 65 53.00 98.07 66 55.00 98.01 67 58.00 98.36 68 60.10 98.62 69 60.10 99.19 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 15 June 2014 Table A.3-11. Summary of calibration details for original and revised input decks, Grant Creek, Transect 100, high flows. WSE (ft) 96.88 97.46 97.72 Disch (cfs) 5.9 15 20 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.00 99.25 2 0.10 98.83 3 2.00 98.82 4 4.00 98.55 5 5.50 98.20 6 7.00 97.84 7 7.20 97.10 0.12 0.19 0.16 0.26 8 7.50 96.76 0.15 0.25 0.19 0.31 9 8.50 96.57 0.15 0.24 0.19 0.31 10 9.50 96.60 0.15 0.25 0.19 0.31 11 11.00 96.70 0.15 0.25 0.19 0.31 12 11.90 96.99 0.14 0.23 0.18 0.30 13 12.20 97.13 0.11 0.18 0.16 0.26 14 13.50 97.16 0.10 0.17 0.15 0.25 15 15.50 96.92 0.15 0.25 0.19 0.31 16 16.00 96.52 0.13 0.23 0.22 0.37 0.25 0.41 17 16.50 96.52 0.13 0.23 0.22 0.37 0.25 0.41 18 17.50 96.22 0.20 0.34 0.27 0.44 0.29 0.48 19 17.70 96.92 0.15 0.25 0.19 0.31 20 18.50 96.92 0.15 0.25 0.19 0.31 21 18.70 95.92 0.15 0.25 0.44 0.31 0.51 0.33 0.54 22 19.00 96.42 0.28 0.28 0.27 0.43 0.39 0.48 0.44 23 19.50 96.12 0.38 0.38 0.37 0.50 0.46 0.54 0.50 24 20.00 96.22 0.44 0.44 0.34 0.60 0.44 0.66 0.48 25 20.50 96.32 0.50 0.50 0.30 0.72 0.42 0.79 0.46 26 21.00 96.17 0.35 0.35 0.36 0.47 0.45 0.51 0.49 27 21.50 95.82 0.43 0.44 0.47 0.52 0.53 0.56 0.56 28 22.00 95.77 0.50 0.51 0.48 0.60 0.54 0.64 0.57 29 22.50 95.72 0.48 0.49 0.50 0.57 0.55 0.61 0.58 30 23.00 95.72 0.46 0.47 0.50 0.55 0.55 0.58 0.58 31 23.50 95.72 0.60 0.61 0.50 0.72 0.55 0.76 0.58 32 24.00 95.92 0.61 0.62 0.44 0.76 0.51 0.82 0.54 33 24.50 95.72 0.58 0.59 0.50 0.69 0.55 0.74 0.58 34 25.00 95.72 0.71 0.74 0.50 0.86 0.55 0.91 0.58 35 25.50 95.72 0.61 0.62 0.50 0.73 0.55 0.77 0.58 36 26.00 96.02 0.57 0.58 0.41 0.73 0.49 0.79 0.52 37 26.50 96.02 0.50 0.51 0.41 0.64 0.49 0.69 0.52 38 27.00 95.97 0.44 0.45 0.42 0.56 0.50 0.60 0.53 39 27.50 96.07 0.51 0.52 0.39 0.66 0.48 0.72 0.51 40 28.00 96.22 0.49 0.49 0.34 0.67 0.44 0.74 0.48 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 16 June 2014 WSE (ft) 96.88 97.46 97.72 Disch (cfs) 5.9 15 20 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 28.50 96.32 0.42 0.42 0.30 0.60 0.42 0.67 0.46 42 29.00 96.12 0.33 0.33 0.37 0.44 0.46 0.47 0.50 43 29.80 96.17 0.22 0.22 0.36 0.30 0.45 0.32 0.49 44 30.60 96.42 0.26 0.26 0.27 0.40 0.39 0.44 0.44 45 31.40 96.52 0.21 0.20 0.23 0.35 0.37 0.39 0.41 46 32.20 96.32 0.01 0.01 0.30 0.01 0.42 0.02 0.46 47 33.00 96.17 0.01 0.01 0.36 0.01 0.45 0.01 0.49 48 33.80 96.42 0.01 0.27 0.01 0.39 0.01 0.44 49 34.60 96.32 0.01 0.30 0.01 0.42 0.01 0.46 50 35.40 96.62 0.01 0.01 0.18 0.02 0.34 0.02 0.39 51 36.20 96.42 0.10 0.10 0.27 0.15 0.39 0.17 0.44 52 37.00 96.32 0.20 0.20 0.30 0.29 0.42 0.32 0.46 53 37.80 96.32 0.28 0.28 0.30 0.40 0.42 0.45 0.46 54 38.60 96.32 0.37 0.37 0.30 0.53 0.42 0.59 0.46 55 39.40 96.32 0.33 0.33 0.30 0.47 0.42 0.52 0.46 56 40.20 96.52 0.02 0.24 0.08 0.42 0.14 0.47 0.15 57 41.00 96.72 0.14 0.05 0.36 0.12 0.42 0.14 58 42.00 96.72 0.14 0.05 0.36 0.12 0.42 0.14 59 43.00 96.77 0.11 0.04 0.34 0.11 0.40 0.13 60 43.50 96.92 0.29 0.09 0.36 0.12 61 45.00 97.19 0.18 0.06 0.27 0.09 62 47.00 97.45 0.02 0.01 0.17 0.06 63 49.00 97.74 64 51.00 98.06 65 53.00 98.07 66 55.00 98.01 67 58.00 98.36 68 60.10 98.62 69 60.10 99.19 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 17 June 2014 Table A.3-12. Summary of calibration details for original and revised input decks, Grant Creek, Transect 110. WSE (ft) 98.22 98.29 99.4 99.84 Disch (cfs) 0.1 0.25 8.69 14.75 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.00 102.77 2 0.10 102.29 3 1.30 101.38 4 2.60 100.08 5 3.80 99.79 0.04 0.03 6 4.80 99.68 0.08 0.07 7 6.90 99.55 0.12 0.10 8 8.00 99.50 0.14 0.11 9 8.50 99.46 0.15 0.12 10 8.60 99.43 0.16 0.12 * 11 9.00 98.73 0.22 * 0.18 0.30 0.24 * 12 10.00 98.63 0.24 * 0.09 0.32 0.12 * 13 11.00 98.43 0.28 * 0.09 0.35 0.11 * 14 12.00 98.43 0.28 * 0.09 0.35 0.11 15 13.00 98.43 0.31 0.28 0.29 0.35 0.36 16 14.00 98.23 0.65 0.59 0.61 0.72 0.72 17 15.00 98.23 0.08 0.08 0.46 0.42 0.43 0.51 0.51 18 16.00 98.13 0.25 0.25 0.33 0.33 1.00 0.91 0.94 1.09 1.09 19 17.00 98.33 0.01 0.01 0.01 0.01 0.01 20 18.00 98.23 0.01 0.01 0.03 0.03 0.03 0.03 21 19.00 98.23 0.01 0.01 0.03 0.03 0.03 0.03 22 20.00 98.28 0.00 0.00 0.03 0.03 0.03 0.03 0.03 23 21.00 98.23 0.04 0.04 0.23 0.21 0.22 0.25 0.25 24 22.00 98.23 0.05 0.05 0.28 0.25 0.26 0.31 0.31 25 23.00 98.13 0.07 0.07 0.09 0.09 0.28 0.25 0.26 0.31 0.31 26 24.00 98.13 0.05 0.05 0.07 0.07 0.21 0.19 0.20 0.23 0.23 27 25.00 98.23 0.04 0.04 0.22 0.20 0.21 0.24 0.24 28 26.00 98.13 0.08 0.08 0.10 0.10 0.32 0.29 0.30 0.35 0.35 29 27.00 98.23 0.06 0.06 0.31 0.28 0.29 0.34 0.34 30 28.00 98.23 0.07 0.07 0.37 0.34 0.35 0.41 0.41 31 29.00 98.13 0.12 0.12 0.15 0.15 0.47 0.43 0.44 0.51 0.51 32 30.00 98.13 0.18 0.18 0.23 0.23 0.70 0.64 0.66 0.76 0.77 33 31.00 98.13 0.13 0.13 0.17 0.17 0.53 0.48 0.50 0.58 0.58 34 32.00 98.03 0.23 0.23 0.25 0.25 0.58 0.53 0.55 0.63 0.63 35 33.00 97.98 0.01 0.01 0.01 0.01 0.03 0.03 0.03 0.03 0.03 36 34.00 98.33 0.02 0.02 0.02 0.02 0.02 37 35.00 98.38 0.02 0.02 0.02 0.02 38 36.00 99.43 0.01 0.01 39 37.00 99.43 0.01 0.01 * 40 38.00 99.03 0.01 0.09 0.01 0.15 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 18 June 2014 WSE (ft) 98.22 98.29 99.4 99.84 Disch (cfs) 0.1 0.25 8.69 14.75 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev * 41 39.00 98.93 0.01 0.09 0.02 0.14 * 42 40.00 98.93 0.01 0.09 0.02 0.14 * 43 41.00 98.93 0.01 0.09 0.02 0.14 * 44 42.00 99.13 0.01 0.09 0.01 0.16 * 45 43.00 99.13 0.01 0.09 0.01 0.16 * 46 44.00 99.23 0.01 0.18 0.01 0.41 47 44.60 99.43 0.01 0.31 48 45.10 99.47 0.01 0.29 49 46.90 99.99 50 48.70 100.31 51 50.80 100.84 52 50.90 101.20 Total 4 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 19 June 2014 Table A.3-13. Summary of calibration details for original and revised input decks, Grant Creek, Transect 110, high flows. WSE (ft) 99.4 99.84 Disch (cfs) 8.69 14.75 20 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.00 102.77 2 0.10 102.29 3 1.30 101.38 4 2.60 100.08 0.04 0.04 5 3.80 99.79 0.03 0.03 0.11 0.11 6 4.80 99.68 0.07 0.07 0.13 0.13 7 6.90 99.55 0.10 0.10 0.16 0.16 8 8.00 99.50 0.11 0.11 0.16 0.17 9 8.50 99.46 0.12 0.12 0.17 0.17 10 8.60 99.43 0.12 0.13 0.18 0.18 11 9.00 98.73 0.18 0.19 0.24 0.25 0.27 0.28 12 10.00 98.63 0.09 0.21 0.12 0.26 0.13 0.29 13 11.00 98.43 0.09 0.24 0.11 0.29 0.13 0.32 14 12.00 98.43 0.09 0.24 0.11 0.29 0.13 0.32 15 13.00 98.43 0.31 0.29 0.24 0.36 0.29 0.39 0.32 16 14.00 98.23 0.65 0.61 0.28 0.72 0.32 0.78 0.34 17 15.00 98.23 0.46 0.43 0.28 0.51 0.32 0.55 0.34 18 16.00 98.13 1.00 0.94 0.29 1.09 0.33 1.17 0.35 19 17.00 98.33 0.01 0.01 0.26 0.01 0.30 0.01 0.33 20 18.00 98.23 0.03 0.28 0.03 0.32 0.04 0.34 21 19.00 98.23 0.03 0.28 0.03 0.32 0.04 0.34 22 20.00 98.28 0.03 0.03 0.27 0.03 0.31 0.04 0.34 23 21.00 98.23 0.23 0.22 0.28 0.25 0.32 0.27 0.34 24 22.00 98.23 0.28 0.26 0.28 0.31 0.32 0.33 0.34 25 23.00 98.13 0.28 0.26 0.29 0.31 0.33 0.33 0.35 26 24.00 98.13 0.21 0.20 0.29 0.23 0.33 0.25 0.35 27 25.00 98.23 0.22 0.21 0.28 0.24 0.32 0.26 0.34 28 26.00 98.13 0.32 0.30 0.29 0.35 0.33 0.38 0.35 29 27.00 98.23 0.31 0.29 0.28 0.34 0.32 0.37 0.34 30 28.00 98.23 0.37 0.35 0.28 0.41 0.32 0.44 0.34 31 29.00 98.13 0.47 0.44 0.29 0.51 0.33 0.55 0.35 32 30.00 98.13 0.70 0.66 0.29 0.77 0.33 0.82 0.35 33 31.00 98.13 0.53 0.50 0.29 0.58 0.33 0.62 0.35 34 32.00 98.03 0.58 0.55 0.31 0.63 0.34 0.67 0.36 35 33.00 97.98 0.03 0.03 0.31 0.03 0.35 0.03 0.37 36 34.00 98.33 0.02 0.02 0.26 0.02 0.30 0.02 0.33 37 35.00 98.38 0.02 0.25 0.02 0.30 0.02 0.32 38 36.00 99.43 0.01 0.13 0.01 0.18 39 37.00 99.43 0.01 0.13 0.01 0.18 40 38.00 99.03 0.09 0.13 0.15 0.20 0.17 0.24 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 20 June 2014 WSE (ft) 99.4 99.84 Disch (cfs) 8.69 14.75 20 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 39.00 98.93 0.09 0.15 0.14 0.22 0.16 0.25 42 40.00 98.93 0.09 0.15 0.14 0.22 0.16 0.25 43 41.00 98.93 0.09 0.15 0.14 0.22 0.16 0.25 44 42.00 99.13 0.09 0.10 0.16 0.18 0.20 0.22 45 43.00 99.13 0.09 0.10 0.16 0.18 0.20 0.22 46 44.00 99.23 0.18 0.08 0.41 0.17 0.51 0.21 47 44.60 99.43 0.31 0.13 0.44 0.18 48 45.10 99.47 0.29 0.12 0.42 0.17 49 46.90 99.99 0.17 0.07 50 48.70 100.31 51 50.80 100.84 52 50.90 101.20 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 21 June 2014 Table A.3- 14. Summary of calibration details for original and revised input decks, Grant Creek, Transect 120. WSE (ft) 95.43 96.46 96.82 97.84 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.00 98.51 2 2.40 97.72 -0.02 -0.08 3 4.50 98.44 4 5.50 98.09 5 5.60 96.87 -0.07 -0.32 * 6 7.20 96.29 -0.01 -0.04 -0.03 -0.03 -0.12 -0.10 -0.44 7 7.60 96.25 0.05 0.05 0.14 0.13 0.13 0.46 0.47 8 8.50 96.79 0.32 0.19 0.19 3.38 3.46 9 9.00 95.87 -0.02 -0.02 -0.03 -0.03 -0.03 -0.08 -0.08 10 11.10 95.69 -0.02 -0.02 -0.04 -0.04 -0.04 -0.10 -0.11 11 12.00 95.19 0.00 0.00 -0.02 -0.02 -0.03 -0.03 -0.03 -0.07 -0.07 12 13.50 94.73 0.14 0.14 0.90 0.91 1.42 1.33 1.35 3.15 3.23 13 15.00 94.09 0.08 0.08 0.41 0.41 0.62 0.58 0.59 1.31 1.34 14 16.00 94.39 0.08 0.08 0.42 0.42 0.65 0.61 0.62 1.40 1.43 15 17.30 93.20 0.23 0.23 1.06 1.06 1.57 1.47 1.50 3.16 3.24 16 18.50 93.19 0.39 0.39 1.74 1.75 2.58 2.43 2.47 5.21 5.33 17 20.10 92.99 0.44 0.44 1.96 1.97 2.89 2.72 2.77 5.79 5.93 18 20.70 94.40 0.47 0.47 2.65 2.66 4.09 3.83 3.90 8.81 9.02 19 21.30 92.95 0.51 0.51 2.28 2.29 3.36 3.17 3.22 6.72 6.88 20 24.00 93.41 0.46 0.46 2.11 2.12 3.14 2.96 3.00 6.39 6.55 21 26.70 93.84 0.31 0.31 1.53 1.53 2.30 2.16 2.20 4.78 4.90 22 30.10 94.81 0.22 0.22 1.51 1.52 2.40 2.25 2.28 5.37 5.50 23 32.80 95.33 0.08 0.08 1.45 1.45 2.43 2.27 2.30 5.83 5.97 24 35.90 95.50 1.10 1.10 1.90 1.77 1.80 4.71 4.82 25 39.00 95.68 0.83 0.83 1.50 1.39 1.42 3.87 3.97 26 41.20 95.68 0.77 0.77 1.39 1.29 1.31 3.59 3.68 27 42.70 95.68 0.62 0.62 1.12 1.04 1.06 2.89 2.96 28 43.20 96.40 0.08 0.08 0.41 0.37 0.37 1.52 1.55 29 44.00 95.77 0.62 0.63 1.16 1.08 1.09 3.07 3.14 30 47.10 96.01 0.48 0.48 1.00 0.92 0.94 2.88 2.95 31 48.90 96.11 0.86 0.86 1.96 1.80 1.83 5.91 6.05 32 50.10 95.84 0.51 0.51 0.97 0.90 0.91 2.62 2.69 33 53.00 95.94 0.77 0.78 1.55 1.43 1.45 4.34 4.44 34 55.70 96.26 0.19 0.19 0.55 0.50 0.51 1.81 1.85 35 59.00 96.39 0.12 0.12 0.57 0.51 0.52 2.09 2.14 36 61.90 96.50 0.30 0.26 0.27 1.25 1.28 37 65.30 96.48 0.24 0.21 0.22 0.97 0.99 38 68.20 96.48 0.36 0.32 0.32 1.46 1.49 * 39 69.90 96.57 0.26 * 1.39 1.16 * 40 72.70 95.89 0.34 0.62 * 1.85 1.16 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 22 June 2014 WSE (ft) 95.43 96.46 96.82 97.84 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 73.50 95.81 0.29 0.29 0.55 0.51 0.52 1.47 1.51 42 75.60 95.43 0.00 0.00 0.53 0.53 0.90 0.84 0.85 2.20 2.25 43 78.50 95.48 0.86 0.87 1.49 1.39 1.41 3.67 3.76 44 81.50 95.51 0.66 0.66 1.14 1.06 1.08 2.83 2.90 45 84.60 95.44 0.46 0.46 0.78 0.73 0.74 1.91 1.96 * 46 86.10 95.79 0.19 0.28 0.35 0.32 0.49 0.93 1.42 * 47 86.70 96.31 0.07 0.20 0.77 0.86 * 48 96.00 96.04 0.14 0.27 * 0.85 0.75 49 142.70 101.45 Total 3 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 23 June 2014 Table A.3-15. Summary of calibration details for original and revised input decks, Grant Creek, Transect 120, high flows. WSE (ft) 96.82 97.84 98.16 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.00 98.51 2 2.40 97.72 -0.08 0.44 -0.22 1.23 3 4.50 98.44 4 5.50 98.09 -0.07 0.36 5 5.60 96.87 -0.32 1.79 -0.46 2.53 6 7.20 96.29 -0.03 -0.12 0.69 -0.44 2.46 -0.59 3.24 7 7.60 96.25 0.14 0.13 0.73 0.47 2.50 0.63 3.29 8 8.50 96.79 0.32 0.19 0.11 3.46 1.89 4.89 2.63 9 9.00 95.87 -0.03 -0.03 1.02 -0.08 2.89 -0.11 3.72 10 11.10 95.69 -0.04 -0.04 1.15 -0.11 3.06 -0.14 3.91 11 12.00 95.19 -0.03 -0.03 1.46 -0.07 3.52 -0.09 4.42 12 13.50 94.73 1.42 1.35 1.73 3.23 3.92 4.07 4.87 13 15.00 94.09 0.62 0.59 2.07 1.34 4.44 1.67 5.46 14 16.00 94.39 0.65 0.62 1.91 1.43 4.20 1.80 5.19 15 17.30 93.20 1.57 1.50 2.50 3.24 5.13 4.00 6.24 16 18.50 93.19 2.58 2.47 2.50 5.33 5.13 6.58 6.24 17 20.10 92.99 2.89 2.77 2.59 5.93 5.28 7.31 6.41 18 20.70 94.40 4.09 3.90 1.91 9.02 4.19 11.31 5.18 19 21.30 92.95 3.36 3.22 2.61 6.88 5.31 8.48 6.44 20 24.00 93.41 3.14 3.00 2.40 6.55 4.97 8.10 6.06 21 26.70 93.84 2.30 2.20 2.19 4.90 4.64 6.09 5.68 22 30.10 94.81 2.40 2.28 1.68 5.50 3.85 6.95 4.79 23 32.80 95.33 2.43 2.30 1.38 5.97 3.40 7.64 4.28 24 35.90 95.50 1.90 1.80 1.27 4.82 3.24 6.20 4.11 25 39.00 95.68 1.50 1.42 1.15 3.97 3.07 5.14 3.92 26 41.20 95.68 1.39 1.31 1.15 3.68 3.07 4.76 3.92 27 42.70 95.68 1.12 1.06 1.15 2.96 3.07 3.84 3.92 28 43.20 96.40 0.41 0.37 0.59 1.55 2.34 2.10 3.11 29 44.00 95.77 1.16 1.09 1.09 3.14 2.98 4.09 3.82 30 47.10 96.01 1.00 0.94 0.92 2.95 2.75 3.88 3.56 31 48.90 96.11 1.96 1.83 0.84 6.05 2.65 8.01 3.45 32 50.10 95.84 0.97 0.91 1.04 2.69 2.92 3.50 3.75 33 53.00 95.94 1.55 1.45 0.97 4.44 2.82 5.83 3.64 34 55.70 96.26 0.55 0.51 0.72 1.85 2.49 2.48 3.28 35 59.00 96.39 0.57 0.52 0.60 2.14 2.35 2.89 3.13 36 61.90 96.50 0.30 0.27 0.49 1.28 2.23 1.74 3.00 37 65.30 96.48 0.24 0.22 0.51 0.99 2.25 1.35 3.02 38 68.20 96.48 0.36 0.32 0.51 1.49 2.25 2.03 3.02 39 69.90 96.57 1.16 1.76 1.67 2.49 40 72.70 95.89 1.16 1.76 1.67 2.49 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 24 June 2014 WSE (ft) 96.82 97.84 98.16 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 73.50 95.81 0.55 0.52 1.06 1.51 2.94 1.97 3.78 42 75.60 95.43 0.90 0.85 1.32 2.25 3.30 2.89 4.18 43 78.50 95.48 1.49 1.41 1.28 3.76 3.26 4.84 4.13 44 81.50 95.51 1.14 1.08 1.26 2.90 3.23 3.73 4.10 45 84.60 95.44 0.78 0.74 1.31 1.96 3.29 2.51 4.17 46 86.10 95.79 0.35 0.49 1.08 1.42 2.96 1.84 3.80 47 86.70 96.31 0.86 1.81 1.23 2.54 48 96.00 96.04 0.75 1.58 1.12 2.30 49 142.70 101.45 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 25 June 2014 Table A.3-16. Summary of calibration details for original and revised input decks, Grant Creek, Transect 130. WSE (ft) 95.5 96.58 97.07 98.74 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 102.04 2 0.1 101.89 3 1.2 99.86 4 3.1 98.88 5 5.4 97.07 0.00 0.00 0.29 0.29 6 5.9 96.12 0.10 0.10 0.18 0.20 0.20 0.39 0.39 7 6.5 95.22 0.02 0.02 0.16 0.16 0.21 0.24 0.24 0.36 0.36 8 8.2 95.37 0.06 0.06 0.63 0.63 0.83 0.93 0.93 1.46 1.46 9 9.1 94.97 0.27 0.27 1.32 1.32 1.64 1.84 1.84 2.71 2.71 10 10.7 94.77 0.47 0.47 2.06 2.06 2.50 2.82 2.82 4.03 4.04 11 12.4 94.47 0.53 0.53 2.03 2.03 2.41 2.72 2.72 3.77 3.77 12 13.8 94.17 0.81 0.81 2.86 2.86 3.34 3.77 3.77 5.08 5.09 13 15.4 94.47 0.88 0.88 3.35 3.35 3.98 4.49 4.49 6.22 6.22 14 16.9 94.47 1.10 1.10 4.22 4.22 5.01 5.66 5.66 7.84 7.84 15 17.9 94.67 0.80 0.80 3.29 3.29 3.97 4.48 4.48 6.33 6.34 16 19.4 94.67 0.84 0.84 3.47 3.47 4.18 4.71 4.71 6.67 6.68 17 21.0 94.62 0.55 0.55 2.22 2.22 2.67 3.01 3.01 4.24 4.24 18 23.1 94.72 0.56 0.56 2.36 2.36 2.86 3.22 3.22 4.59 4.59 19 24.4 94.97 0.38 0.38 1.91 1.91 2.37 2.66 2.66 3.92 3.92 20 26.0 95.07 0.24 0.24 1.35 1.35 1.69 1.90 1.90 2.83 2.84 21 28.3 95.27 0.14 0.14 1.05 1.05 1.35 1.51 1.51 2.33 2.33 22 31.0 95.47 0.03 0.03 0.84 0.84 1.12 1.25 1.25 2.01 2.01 23 33.7 95.77 0.74 0.74 1.07 1.19 1.19 2.05 2.05 24 36.6 95.97 0.52 0.52 0.82 0.90 0.90 1.67 1.67 25 39.3 96.07 0.55 0.55 0.91 1.00 1.00 1.92 1.92 26 42.4 96.47 0.02 0.02 0.07 0.07 0.07 0.18 0.18 27 43.4 96.77 0.38 0.38 0.38 1.33 1.33 28 44.9 96.57 0.04 0.04 0.64 0.67 0.67 1.79 1.79 29 45.9 96.62 0.52 0.54 0.54 1.52 1.52 30 47.4 96.67 0.31 0.32 0.32 0.96 0.96 31 50.0 96.97 0.10 0.08 0.08 0.55 0.55 32 50.6 96.97 0.01 0.01 0.01 0.05 0.05 33 53.1 97.02 0.00 0.01 0.01 0.05 0.05 34 57.0 96.97 0.01 0.01 0.01 0.05 0.05 35 60.6 96.97 0.01 0.01 0.01 0.05 0.05 36 62.7 96.77 0.04 0.04 0.04 0.14 0.14 37 65.3 96.77 0.90 0.90 0.90 3.15 3.15 38 67.8 96.72 1.08 1.10 1.10 3.53 3.53 39 72.0 96.87 2.11 1.99 1.99 8.80 8.81 40 74.5 96.92 1.44 1.29 1.29 6.77 6.78 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 26 June 2014 WSE (ft) 95.5 96.58 97.07 98.74 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 77.1 96.97 0.60 0.49 0.49 3.29 3.29 42 79.9 97.02 0.40 0.26 0.26 2.72 2.72 * 43 80.4 97.07 0.02 2.66 2.66 * 44 81.9 97.01 0.29 * 2.73 2.58 45 83.0 97.22 2.50 2.50 46 84.9 97.19 2.53 2.54 47 85.8 98.10 1.40 1.40 48 87.6 97.48 2.20 2.21 49 89.1 97.34 2.37 2.37 50 92.0 97.26 2.46 2.46 51 94.5 97.26 2.46 2.46 52 96.7 97.38 2.32 2.32 53 97.7 97.92 1.65 1.65 54 100.2 98.06 1.46 1.46 55 103.2 98.62 0.45 0.45 56 106.8 98.80 57 109.5 98.18 1.28 1.28 58 111.8 98.09 1.41 1.41 59 114.7 97.94 1.62 1.63 60 117.2 97.98 1.57 1.57 61 120.3 97.94 1.62 1.63 62 122.7 98.55 0.61 0.61 63 125.8 98.18 1.28 1.28 64 128.5 98.54 0.63 0.64 65 131.7 98.86 66 134.6 99.32 67 135.6 100.92 Total 1 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 27 June 2014 Table A.3-17. Summary of calibration details for original and revised input decks, Grant Creek, Transect 130, high flows. WSE (ft) 97.07 98.74 99.35 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 102.04 2 0.1 101.89 3 1.2 99.86 4 3.1 98.88 0.12 0.90 5 5.4 97.07 0.00 0.02 0.29 2.15 0.34 2.58 6 5.9 96.12 0.18 0.20 1.55 0.39 2.91 0.43 3.26 7 6.5 95.22 0.21 0.24 2.42 0.36 3.55 0.39 3.84 8 8.2 95.37 0.83 0.93 2.29 1.46 3.45 1.58 3.75 9 9.1 94.97 1.64 1.84 2.64 2.71 3.72 2.91 4.00 10 10.7 94.77 2.50 2.82 2.80 4.04 3.85 4.30 4.12 11 12.4 94.47 2.41 2.72 3.04 3.77 4.04 4.00 4.30 12 13.8 94.17 3.34 3.77 3.27 5.09 4.23 5.36 4.47 13 15.4 94.47 3.98 4.49 3.04 6.22 4.04 6.59 4.30 14 16.9 94.47 5.01 5.66 3.04 7.84 4.04 8.31 4.30 15 17.9 94.67 3.97 4.48 2.88 6.34 3.92 6.74 4.18 16 19.4 94.67 4.18 4.71 2.88 6.68 3.92 7.10 4.18 17 21.0 94.62 2.67 3.01 2.92 4.24 3.95 4.51 4.21 18 23.1 94.72 2.86 3.22 2.84 4.59 3.88 4.89 4.15 19 24.4 94.97 2.37 2.66 2.64 3.92 3.72 4.20 4.00 20 26.0 95.07 1.69 1.90 2.55 2.84 3.65 3.04 3.94 21 28.3 95.27 1.35 1.51 2.38 2.33 3.52 2.52 3.81 22 31.0 95.47 1.12 1.25 2.20 2.01 3.38 2.18 3.69 23 33.7 95.77 1.07 1.19 1.91 2.05 3.17 2.25 3.49 24 36.6 95.97 0.82 0.90 1.71 1.67 3.02 1.85 3.36 25 39.3 96.07 0.91 1.00 1.60 1.92 2.95 2.13 3.29 26 42.4 96.47 0.07 0.07 1.14 0.18 2.65 0.21 3.02 27 43.4 96.77 0.38 0.38 0.72 1.33 2.41 1.55 2.81 28 44.9 96.57 0.64 0.67 1.01 1.79 2.57 2.05 2.95 29 45.9 96.62 0.52 0.54 0.94 1.52 2.53 1.75 2.91 30 47.4 96.67 0.31 0.32 0.87 0.96 2.49 1.10 2.88 31 50.0 96.97 0.10 0.08 0.35 0.55 2.24 0.65 2.66 32 50.6 96.97 0.01 0.01 0.35 0.05 2.24 0.06 2.66 33 53.1 97.02 0.0 0.01 0.22 0.05 2.20 0.06 2.62 34 57.0 96.97 0.01 0.01 0.35 0.05 2.24 0.06 2.66 35 60.6 96.97 0.01 0.01 0.35 0.05 2.24 0.06 2.66 36 62.7 96.77 0.04 0.04 0.72 0.14 2.41 0.16 2.81 37 65.3 96.77 0.90 0.90 0.72 3.15 2.41 3.66 2.81 38 67.8 96.72 1.08 1.10 0.80 3.53 2.45 4.09 2.84 39 72.0 96.87 2.11 1.99 0.55 8.81 2.32 10.32 2.73 40 74.5 96.92 1.44 1.29 0.45 6.78 2.28 7.97 2.70 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 28 June 2014 WSE (ft) 97.07 98.74 99.35 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 77.1 96.97 0.60 0.49 0.35 3.29 2.24 3.89 2.66 42 79.9 97.02 0.40 0.26 0.22 2.72 2.20 3.23 2.62 43 80.4 97.07 2.66 2.14 3.18 2.58 44 81.9 97.01 2.58 2.08 3.11 2.52 45 83.0 97.22 2.50 2.02 3.04 2.47 46 84.9 97.19 2.54 2.05 3.07 2.49 47 85.8 98.10 1.40 1.13 2.13 1.73 48 87.6 97.48 2.21 1.78 2.79 2.26 49 89.1 97.34 2.37 1.91 2.93 2.37 50 92.0 97.26 2.46 1.99 3.01 2.44 51 94.5 97.26 2.46 1.99 3.01 2.44 52 96.7 97.38 2.32 1.88 2.89 2.34 53 97.7 97.92 1.65 1.33 2.33 1.89 54 100.2 98.06 1.46 1.18 2.18 1.76 55 103.2 98.62 0.45 0.36 1.49 1.21 56 106.8 98.80 1.23 1.00 57 109.5 98.18 1.28 1.03 2.04 1.65 58 111.8 98.09 1.41 1.14 2.14 1.74 59 114.7 97.94 1.63 1.31 2.31 1.87 60 117.2 97.98 1.57 1.27 2.27 1.84 61 120.3 97.94 1.63 1.31 2.31 1.87 62 122.7 98.55 0.61 0.50 1.58 1.28 63 125.8 98.18 1.28 1.03 2.04 1.65 64 128.5 98.54 0.64 0.51 1.59 1.29 65 131.7 98.86 1.14 0.92 66 134.6 99.32 0.18 0.15 67 135.6 100.92 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 29 June 2014 Table A.3-18. Summary of calibration details for original and revised input decks, Grant Creek, Transect 140. WSE (ft) 97.24 97.85 98.16 99.27 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.00 101.83 2 0.00 101.08 3 3.60 100.62 4 7.00 100.61 5 9.80 100.12 6 11.00 99.85 7 12.50 98.14 0.02 0.04 0.21 0.54 8 13.10 97.84 0.01 0.04 0.11 0.11 0.28 0.25 0.63 9 14.00 97.44 0.55 0.62 0.77 0.73 0.84 1.16 1.27 10 15.00 96.84 1.25 1.25 3.96 4.41 4.57 4.30 4.93 5.49 6.02 11 16.50 97.34 4.28 4.76 5.62 5.32 6.10 8.01 8.78 12 18.10 97.24 0.08 0.08 5.25 5.84 6.62 6.26 7.17 9.02 9.88 * 13 19.10 97.04 1.25 1.25 5.40 6.01 6.45 6.08 6.97 8.18 8.97 14 20.50 96.74 1.95 1.95 5.66 6.30 6.44 6.06 6.94 7.57 8.29 15 21.50 96.64 1.84 1.84 5.00 5.56 5.62 5.28 6.05 6.47 7.09 16 23.10 96.64 1.37 1.37 3.72 4.13 4.18 3.93 4.50 4.81 5.27 17 24.20 96.54 1.51 1.51 3.91 4.36 4.36 4.10 4.69 4.93 5.40 18 25.50 96.64 1.79 1.79 4.86 5.41 5.47 5.14 5.89 6.30 6.90 19 26.50 96.74 1.64 1.64 4.75 5.28 5.40 5.08 5.82 6.34 6.95 20 28.40 96.94 1.17 1.17 4.18 4.65 4.90 4.62 5.29 6.04 6.62 21 31.10 96.84 1.13 1.13 3.58 3.99 4.13 3.89 4.45 4.96 5.44 22 34.10 97.34 1.00 1.11 1.31 1.24 1.42 1.87 2.05 * 23 36.60 97.74 1.57 1.32 3.54 3.40 2.96 6.87 5.72 * 24 39.20 97.64 3.32 3.03 5.72 5.47 5.13 9.97 8.95 * 25 41.40 97.21 0.61 6.98 8.22 * 11.69 6.53 * 26 43.00 97.53 4.43 6.25 * 10.44 6.74 27 44.30 97.84 0.31 0.35 2.33 2.26 2.59 5.24 5.74 28 47.20 97.54 1.71 1.91 2.58 2.46 2.81 4.14 4.54 29 49.60 97.84 0.37 0.41 2.76 2.68 3.07 6.21 6.80 30 53.90 97.84 0.50 0.56 3.76 3.65 4.18 8.46 9.27 31 56.50 97.94 1.57 1.55 1.78 4.41 4.84 32 59.30 97.84 0.48 0.53 3.56 3.46 3.96 8.01 8.77 33 61.60 97.99 1.29 1.30 1.49 4.29 4.70 34 63.70 97.94 3.49 3.46 3.96 9.81 10.75 35 66.00 97.54 1.34 1.20 1.34 1.81 1.72 1.97 2.91 3.19 36 70.00 96.74 1.22 1.22 3.54 3.94 4.03 3.79 4.34 4.73 5.19 37 74.40 100.17 38 76.20 100.23 39 78.00 100.11 40 79.90 97.84 0.25 0.28 1.89 1.84 2.10 4.25 4.66 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 30 June 2014 WSE (ft) 97.24 97.85 98.16 99.27 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 83.00 97.84 0.17 0.19 1.29 1.25 1.44 2.90 3.18 42 86.00 97.84 0.13 0.14 0.97 0.94 1.08 2.18 2.39 43 89.50 97.69 0.18 0.20 0.34 0.33 0.37 0.62 0.68 * 44 90.30 97.84 0.00 0.02 0.01 0.01 0.12 0.02 0.27 45 93.40 97.84 0.00 0.02 0.01 0.12 0.02 0.27 46 93.80 98.14 0.00 0.02 0.02 0.23 47 96.00 99.33 48 99.50 99.52 49 102.70 99.24 0.00 0.02 50 107.00 99.20 0.00 0.04 51 110.10 98.80 0.01 0.13 52 113.40 98.46 0.02 0.19 * 53 120.00 98.04 0.01 0.02 0.19 54 123.70 98.45 0.02 0.19 55 123.70 102.44 Total 2 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 31 June 2014 Table A.3-19. Summary of calibration details for original and revised input decks, Grant Creek, Transect 140, high flows. WSE (ft) 98.16 99.27 99.7 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 101.83 2 0.0 101.08 3 3.6 100.62 4 7.0 100.61 5 9.8 100.12 6 11.0 99.85 7 12.5 98.14 0.04 0.30 0.54 3.78 0.66 4.51 8 13.1 97.84 0.11 0.28 1.98 0.63 4.43 0.74 5.07 9 14.0 97.44 0.77 0.84 3.42 1.27 5.22 1.44 5.78 10 15.0 96.84 4.57 4.93 5.14 6.02 6.32 6.60 6.76 11 16.5 97.34 5.62 6.10 3.73 8.78 5.41 9.89 5.95 12 18.1 97.24 6.62 7.17 4.03 9.88 5.60 11.06 6.11 13 19.1 97.04 6.45 6.97 4.60 8.97 5.97 9.93 6.44 14 20.5 96.74 6.44 6.94 5.39 8.29 6.49 9.06 6.92 15 21.5 96.64 5.62 6.05 5.64 7.09 6.66 7.72 7.08 16 23.1 96.64 4.18 4.50 5.64 5.27 6.66 5.74 7.08 17 24.2 96.54 4.36 4.69 5.89 5.40 6.83 5.86 7.23 18 25.5 96.64 5.47 5.89 5.64 6.90 6.66 7.51 7.08 19 26.5 96.74 5.40 5.82 5.39 6.95 6.49 7.60 6.92 20 28.4 96.94 4.90 5.29 4.87 6.62 6.14 7.29 6.60 21 31.1 96.84 4.13 4.45 5.14 5.44 6.32 5.97 6.76 22 34.1 97.34 1.31 1.42 3.73 2.05 5.41 2.30 5.95 * 23 36.6 97.74 3.54 2.96 2.38 5.72 4.63 6.64 5.25 * 24 39.2 97.64 5.72 5.13 2.75 8.95 4.83 10.30 5.43 * 25 41.4 97.21 6.53 3.53 8.15 4.29 * 26 43.0 97.53 6.74 3.64 8.33 4.39 27 44.3 97.84 2.33 2.59 1.98 5.74 4.43 6.74 5.07 28 47.2 97.54 2.58 2.81 3.09 4.54 5.03 5.19 5.60 29 49.6 97.84 2.76 3.07 1.98 6.80 4.43 7.99 5.07 30 53.9 97.84 3.76 4.18 1.98 9.27 4.43 10.88 5.07 31 56.5 97.94 1.57 1.78 1.54 4.84 4.22 5.75 4.89 32 59.3 97.84 3.56 3.96 1.98 8.77 4.43 10.30 5.07 33 61.6 97.99 1.29 1.49 1.30 4.70 4.11 5.61 4.79 34 63.7 97.94 3.49 3.96 1.54 10.75 4.22 12.77 4.89 35 66.0 97.54 1.81 1.97 3.09 3.19 5.03 3.64 5.60 36 70.0 96.74 4.03 4.34 5.39 5.19 6.49 5.67 6.92 37 74.4 100.17 38 76.2 100.23 39 78.0 100.11 40 79.9 97.84 1.89 2.10 1.98 4.66 4.43 5.47 5.07 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 32 June 2014 WSE (ft) 98.16 99.27 99.7 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 83.0 97.84 1.29 1.44 1.98 3.18 4.43 3.73 5.07 42 86.0 97.84 0.97 1.08 1.98 2.39 4.43 2.81 5.07 43 89.5 97.69 0.34 0.37 2.57 0.68 4.73 0.79 5.34 * 44 90.3 97.84 0.01 0.12 1.98 0.27 4.43 0.32 5.07 45 93.4 97.84 0.12 1.98 0.27 4.43 0.32 5.07 46 93.8 98.14 0.02 0.30 0.23 3.78 0.29 4.51 47 96.0 99.33 0.11 1.73 48 99.5 99.52 0.07 1.07 49 102.7 99.24 0.02 0.32 0.13 1.99 50 107.0 99.20 0.04 0.57 0.13 2.11 51 110.1 98.80 0.13 2.10 0.20 3.12 52 113.4 98.46 0.19 3.02 0.24 3.87 * 53 120.0 98.04 0.19 3.05 0.25 3.89 54 123.7 98.45 0.19 3.05 0.25 3.89 55 123.7 102.44 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 33 June 2014 Table A.3-20. Summary of calibration details for original and revised input decks, Grant Creek, Transect 150. WSE (ft) 94.21 94.86 95.23 96.24 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 100.14 * 2 1.8 94.68 0.26 0.56 * 1.32 0.35 3 2.5 94.92 0.38 0.38 0.38 1.18 1.18 4 3.0 94.72 0.44 0.44 1.11 1.10 1.10 2.68 2.70 5 3.5 94.72 0.31 1.80 2.51 * 2.48 4.41 * 6 4.5 94.92 3.72 3.71 3.02 11.50 9.41 7 5.7 94.32 1.66 1.65 2.53 2.50 2.51 4.82 4.85 8 6.6 94.42 0.09 0.09 0.15 0.14 0.15 0.29 0.29 9 7.3 94.32 2.04 2.04 3.12 3.08 3.09 5.94 5.98 10 9.2 94.72 1.48 1.48 3.74 3.71 3.72 9.03 9.08 11 11.3 94.52 1.66 1.66 2.92 2.89 2.90 6.11 6.15 12 12.8 94.62 0.76 0.75 1.51 1.50 1.50 3.37 3.39 13 14.3 94.92 0.10 0.10 0.10 0.31 0.31 14 16.0 94.92 1.15 1.15 1.15 3.56 3.58 15 17.9 94.77 0.95 0.95 2.97 2.95 2.95 7.52 7.57 16 19.0 94.65 1.46 1.46 3.08 3.05 3.06 7.02 7.06 17 20.3 94.62 1.79 1.79 3.58 3.54 3.55 7.98 8.03 18 21.4 94.57 1.90 1.89 3.52 3.48 3.49 7.59 7.64 19 22.7 94.52 0.74 0.74 1.30 1.29 1.29 2.72 2.74 20 23.8 94.32 1.66 1.66 2.54 2.51 2.52 4.84 4.87 21 25.1 94.12 0.22 0.22 1.74 1.74 2.47 2.44 2.44 4.39 4.42 22 27.5 93.92 0.50 0.50 2.16 2.15 2.91 2.87 2.88 4.92 4.95 23 29.4 93.92 0.42 0.42 1.81 1.80 2.44 2.41 2.41 4.12 4.15 24 32.3 93.92 0.50 0.50 2.18 2.17 2.94 2.90 2.91 4.97 5.00 25 34.8 94.12 0.35 0.35 2.78 2.77 3.94 3.89 3.90 7.01 7.05 26 36.9 94.22 2.51 2.51 3.68 3.63 3.64 6.75 6.80 27 39.2 94.07 0.40 0.40 2.49 2.48 3.48 3.43 3.44 6.10 6.14 28 41.6 93.82 0.56 0.56 2.16 2.15 2.86 2.82 2.83 4.73 4.76 29 44.3 93.72 0.68 0.68 2.38 2.37 3.11 3.07 3.07 5.05 5.08 30 46.0 93.72 0.98 0.98 3.41 3.41 4.46 4.40 4.41 7.24 7.28 31 48.2 93.52 0.57 0.57 1.76 1.75 2.24 2.21 2.21 3.52 3.54 32 50.4 93.37 0.98 0.98 2.84 2.83 3.57 3.52 3.53 5.49 5.52 33 52.5 93.47 0.98 0.98 2.97 2.96 3.77 3.72 3.73 5.88 5.91 34 53.8 93.42 0.96 0.96 2.84 2.84 3.59 3.54 3.55 5.56 5.59 35 55.7 93.42 1.12 1.12 3.32 3.31 4.19 4.13 4.14 6.49 6.53 36 56.9 93.82 0.31 0.31 1.18 1.18 1.57 1.55 1.55 2.60 2.61 37 57.6 93.97 0.65 0.64 3.07 3.06 4.18 4.12 4.13 7.14 7.19 38 59.0 94.12 0.14 0.14 1.10 1.10 1.56 1.54 1.54 2.77 2.79 39 60.5 94.32 2.46 2.45 3.75 3.70 3.71 7.14 7.18 40 61.8 94.42 1.87 1.87 3.03 3.00 3.00 6.02 6.06 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 34 June 2014 WSE (ft) 94.21 94.86 95.23 96.24 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 63.0 94.22 1.49 1.49 2.18 2.15 2.16 4.00 4.03 * 42 65.5 95.02 0.02 0.02 0.13 0.08 0.49 43 67.1 95.02 0.04 0.04 0.13 0.15 0.49 44 69.8 95.80 0.08 0.25 45 72.2 95.88 0.07 0.22 46 75.0 95.84 0.07 0.23 47 78.0 95.86 0.07 0.22 48 81.0 96.26 49 84.0 96.13 0.03 0.10 50 87.0 96.49 51 90.0 96.47 52 93.0 96.57 53 96.0 96.61 54 99.0 96.07 0.04 0.13 55 102.0 96.93 56 105.0 96.79 57 106.9 97.16 58 108.5 96.33 59 111.0 96.00 0.05 0.17 60 114.0 95.67 0.09 0.29 61 117.0 95.80 0.08 0.25 62 119.0 95.51 0.11 0.35 * 63 120.0 95.15 0.02 0.14 0.43 * 64 121.7 94.91 0.05 0.16 0.40 65 123.6 95.38 0.12 0.39 66 125.9 97.23 67 125.9 97.45 Total 2 * * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 35 June 2014 Table A.3-21. Summary of calibration details for original and revised input decks, Grant Creek, Transect 150, high flows. WSE (ft) 95.23 96.24 96.65 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 100.14 2 1.8 94.68 0.35 1.06 0.75 2.22 3 2.5 94.92 0.38 0.38 1.18 1.18 3.62 1.49 4.42 4 3.0 94.72 1.11 1.10 1.65 2.70 3.98 3.33 4.76 5 3.5 94.72 2.51 2.48 2.90 4.41 5.09 5.20 5.81 6 4.5 94.92 3.72 3.02 1.18 9.41 3.62 11.87 4.42 7 5.7 94.32 2.53 2.51 2.43 4.85 4.66 5.81 5.40 8 6.6 94.42 0.15 0.15 2.25 0.29 4.49 0.35 5.24 9 7.3 94.32 3.12 3.09 2.43 5.98 4.66 7.16 5.40 10 9.2 94.72 3.74 3.72 1.65 9.08 3.98 11.22 4.76 11 11.3 94.52 2.92 2.90 2.06 6.15 4.33 7.47 5.08 12 12.8 94.62 1.51 1.50 1.86 3.39 4.16 4.15 4.92 13 14.3 94.92 0.10 0.10 1.18 0.31 3.62 0.39 4.42 14 16.0 94.92 1.15 1.15 1.18 3.58 3.62 4.51 4.42 15 17.9 94.77 2.97 2.95 1.54 7.57 3.90 9.39 4.67 16 19.0 94.65 3.08 3.06 1.80 7.06 4.11 8.67 4.87 17 20.3 94.62 3.58 3.55 1.86 8.03 4.16 9.83 4.92 18 21.4 94.57 3.52 3.49 1.96 7.64 4.24 9.31 5.00 19 22.7 94.52 1.30 1.29 2.06 2.74 4.33 3.33 5.08 20 23.8 94.32 2.54 2.52 2.43 4.87 4.66 5.83 5.40 21 25.1 94.12 2.47 2.44 2.78 4.42 4.98 5.24 5.71 22 27.5 93.92 2.91 2.88 3.11 4.95 5.29 5.81 6.00 23 29.4 93.92 2.44 2.41 3.11 4.15 5.29 4.87 6.00 24 32.3 93.92 2.94 2.91 3.11 5.00 5.29 5.87 6.00 25 34.8 94.12 3.94 3.90 2.78 7.05 4.98 8.36 5.71 26 36.9 94.22 3.68 3.64 2.61 6.80 4.82 8.10 5.55 27 39.2 94.07 3.48 3.44 2.87 6.14 5.06 7.26 5.78 28 41.6 93.82 2.86 2.83 3.27 4.76 5.44 5.56 6.15 29 44.3 93.72 3.11 3.07 3.42 5.08 5.59 5.91 6.30 30 46.0 93.72 4.46 4.41 3.42 7.28 5.59 8.48 6.30 31 48.2 93.52 2.24 2.21 3.72 3.54 5.88 4.09 6.58 32 50.4 93.37 3.57 3.53 3.94 5.52 6.10 6.36 6.79 33 52.5 93.47 3.77 3.73 3.79 5.91 5.95 6.83 6.65 34 53.8 93.42 3.59 3.55 3.86 5.59 6.03 6.45 6.72 35 55.7 93.42 4.19 4.14 3.86 6.53 6.03 7.53 6.72 36 56.9 93.82 1.57 1.55 3.27 2.61 5.44 3.05 6.15 37 57.6 93.97 4.18 4.13 3.03 7.19 5.21 8.46 5.93 38 59.0 94.12 1.56 1.54 2.78 2.79 4.98 3.31 5.71 39 60.5 94.32 3.75 3.71 2.43 7.18 4.66 8.61 5.40 40 61.8 94.42 3.03 3.00 2.25 6.06 4.49 7.31 5.24 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 36 June 2014 WSE (ft) 95.23 96.24 96.65 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 63.0 94.22 2.18 2.16 2.61 4.03 4.82 4.80 5.55 42 65.5 95.02 0.02 0.13 0.90 0.49 3.44 0.63 4.25 43 67.1 95.02 0.04 0.13 0.90 0.49 3.44 0.63 4.25 44 69.8 95.80 0.25 1.74 0.40 2.74 45 72.2 95.88 0.22 1.52 0.38 2.57 46 75.0 95.84 0.23 1.63 0.39 2.65 47 78.0 95.86 0.22 1.57 0.39 2.61 48 81.0 96.26 0.24 1.62 49 84.0 96.13 0.10 0.69 0.29 1.97 50 87.0 96.49 0.13 0.89 51 90.0 96.47 0.14 0.96 52 93.0 96.57 0.08 0.55 53 96.0 96.61 0.05 0.34 54 99.0 96.07 0.13 0.92 0.31 2.12 55 102.0 96.93 56 105.0 96.79 57 106.9 97.16 58 108.5 96.33 0.21 1.42 59 111.0 96.00 0.17 1.16 0.34 2.29 60 114.0 95.67 0.29 2.07 0.45 3.02 61 117.0 95.80 0.25 1.74 0.40 2.74 62 119.0 95.51 0.35 2.44 0.49 3.34 63 120.0 95.15 0.43 3.03 0.57 3.87 64 121.7 94.91 0.40 2.83 0.54 3.69 65 123.6 95.38 0.39 2.72 0.53 3.59 66 125.9 97.23 67 125.9 97.45 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 37 June 2014 Table A.3-22. Summary of calibration details for original and revised input decks, Grant Creek, Transect 160. WSE (ft) 94.3 95.11 95.49 96.44 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 99.27 2 0.0 98.61 3 1.3 98.35 4 2.6 97.76 5 5.5 97.44 6 8.3 97.24 7 11.1 96.65 8 11.2 95.69 1.52 0.77 * 9 11.5 95.43 0.23 * 0.09 1.84 0.94 * 10 11.9 95.33 0.38 * 0.18 1.96 1.01 * 11 13.5 95.33 0.38 * 0.18 1.96 1.01 * 12 14.0 95.43 0.23 * 0.17 1.84 1.85 * 13 15.7 95.43 0.23 * 0.17 1.84 1.85 * 14 17.6 95.43 0.23 * 0.17 1.84 1.85 * 15 20.2 95.43 0.23 * 0.17 1.84 1.85 * 16 22.0 95.43 0.23 * 0.17 1.84 1.85 17 22.8 94.93 0.30 0.29 0.77 0.81 0.81 2.40 2.44 18 23.5 95.13 0.01 0.71 0.80 0.79 2.83 2.88 19 24.5 94.83 0.48 0.47 1.06 1.10 1.10 3.05 3.10 20 25.5 94.83 0.42 0.42 0.93 0.96 0.97 2.67 2.72 21 26.5 94.73 0.61 0.60 1.22 1.25 1.26 3.29 3.35 22 27.7 94.83 0.53 0.52 1.16 1.20 1.21 3.33 3.40 23 29.5 94.73 0.27 0.27 0.55 0.56 0.57 1.48 1.51 24 31.0 94.83 0.72 0.71 1.59 1.65 1.66 4.57 4.66 25 32.5 94.83 0.67 0.66 1.47 1.52 1.53 4.22 4.30 26 34.5 94.83 0.55 0.54 1.20 1.24 1.25 3.45 3.51 27 36.2 95.03 0.50 0.44 1.74 1.88 1.87 6.01 6.12 28 37.5 94.93 0.59 0.56 1.50 1.58 1.58 4.67 4.75 29 38.7 94.93 0.47 0.45 1.21 1.27 1.28 3.77 3.83 30 40.6 95.03 0.47 0.42 1.65 1.78 1.78 5.70 5.80 31 41.5 94.53 1.07 1.07 1.94 1.95 1.98 4.76 4.85 32 42.5 94.53 1.18 1.19 2.15 2.16 2.19 5.27 5.38 33 44.0 94.53 1.47 1.48 2.67 2.68 2.72 6.55 6.68 34 45.3 94.83 1.12 1.10 2.46 2.55 2.56 7.07 7.20 35 46.4 94.53 1.42 1.42 2.57 2.58 2.62 6.30 6.43 36 47.4 94.13 0.10 1.12 1.14 1.85 1.82 1.86 4.02 4.11 37 49.1 93.93 0.21 0.21 1.59 1.61 2.55 2.50 2.55 5.32 5.44 38 50.0 93.73 0.26 0.26 1.67 1.70 2.63 2.57 2.62 5.31 5.43 39 52.4 93.78 0.30 0.30 1.96 1.99 3.10 3.03 3.10 6.31 6.45 40 54.5 93.53 0.33 0.33 1.87 1.91 2.91 2.83 2.90 5.72 5.85 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 38 June 2014 WSE (ft) 94.3 95.11 95.49 96.44 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 57.0 93.03 0.46 0.45 2.20 2.25 3.34 3.23 3.31 6.24 6.39 42 59.5 92.83 0.48 0.47 2.21 2.25 3.32 3.20 3.28 6.10 6.25 43 61.8 92.83 0.41 0.41 1.92 1.96 2.89 2.79 2.86 5.31 5.44 44 63.8 92.93 0.37 0.37 1.75 1.79 2.65 2.55 2.62 4.90 5.02 45 66.0 93.03 0.35 0.35 1.68 1.71 2.54 2.45 2.52 4.74 4.86 46 67.6 92.83 0.30 0.30 1.39 1.42 2.09 2.01 2.06 3.83 3.93 47 69.1 93.03 0.33 0.33 1.60 1.64 2.43 2.35 2.41 4.54 4.65 48 70.6 93.13 0.19 0.18 0.91 0.93 1.39 1.34 1.38 2.62 2.68 49 72.8 93.53 0.26 0.26 1.47 1.49 2.28 2.22 2.27 4.48 4.59 50 74.5 93.63 0.22 0.22 1.32 1.35 2.07 2.02 2.06 4.12 4.22 51 76.7 94.03 0.12 0.12 1.08 1.09 1.75 1.72 1.76 3.72 3.81 52 77.4 94.03 0.10 0.10 0.87 0.89 1.42 1.40 1.42 3.02 3.09 53 78.2 94.43 -0.02 - 0.02 -0.04 -0.04 - 0.04 -0.09 -0.10 54 79.0 94.78 0.86 0.84 1.79 1.84 1.86 4.97 5.07 55 80.2 94.88 0.23 0.23 0.55 0.57 0.58 1.64 1.67 56 81.6 95.03 0.22 0.20 0.78 0.84 0.84 2.69 2.74 57 83.1 95.13 0.01 0.44 0.49 0.49 1.76 1.79 58 84.6 95.68 1.23 1.24 59 86.3 96.71 60 88.5 96.98 61 88.5 97.39 Total 8 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 39 June 2014 Table A.3-23. Summary of calibration details for original and revised input decks, Grant Creek, Transect T160, high flows. WSE (ft) 95.49 96.44 96.78 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 99.27 2 0.0 98.61 3 1.3 98.35 4 2.6 97.76 5 5.5 97.44 6 8.3 97.24 7 11.1 96.65 0.28 0.72 8 11.2 95.69 0.77 2.02 1.13 2.96 9 11.5 95.43 0.09 0.22 0.94 2.45 1.30 3.39 10 11.9 95.33 0.18 0.46 1.01 2.62 1.37 3.58 11 13.5 95.33 0.18 0.46 1.01 2.62 1.37 3.58 12 14.0 95.43 0.17 0.22 1.85 2.45 2.56 3.39 13 15.7 95.43 0.17 0.22 1.85 2.45 2.56 3.39 14 17.6 95.43 0.17 0.22 1.85 2.45 2.56 3.39 15 20.2 95.43 0.17 0.22 1.85 2.45 2.56 3.39 16 22.0 95.43 0.17 0.22 1.85 2.45 2.56 3.39 17 22.8 94.93 0.77 0.81 1.06 2.44 3.23 3.18 4.21 18 23.5 95.13 0.71 0.79 0.79 2.88 2.93 3.82 3.90 19 24.5 94.83 1.06 1.10 1.18 3.10 3.37 4.01 4.36 20 25.5 94.83 0.93 0.97 1.18 2.72 3.37 3.52 4.36 21 26.5 94.73 1.22 1.26 1.29 3.35 3.51 4.31 4.51 22 27.7 94.83 1.16 1.21 1.18 3.40 3.37 4.39 4.36 23 29.5 94.73 0.55 0.57 1.29 1.51 3.51 1.94 4.51 24 31.0 94.83 1.59 1.66 1.18 4.66 3.37 6.02 4.36 25 32.5 94.83 1.47 1.53 1.18 4.30 3.37 5.57 4.36 26 34.5 94.83 1.20 1.25 1.18 3.51 3.37 4.54 4.36 27 36.2 95.03 1.74 1.87 0.93 6.12 3.08 8.04 4.06 28 37.5 94.93 1.50 1.58 1.06 4.75 3.23 6.20 4.21 29 38.7 94.93 1.21 1.28 1.06 3.83 3.23 5.00 4.21 30 40.6 95.03 1.65 1.78 0.93 5.80 3.08 7.62 4.06 31 41.5 94.53 1.94 1.98 1.51 4.85 3.78 6.16 4.80 32 42.5 94.53 2.15 2.19 1.51 5.38 3.78 6.83 4.80 33 44.0 94.53 2.67 2.72 1.51 6.68 3.78 8.48 4.80 34 45.3 94.83 2.46 2.56 1.18 7.20 3.37 9.31 4.36 35 46.4 94.53 2.57 2.62 1.51 6.43 3.78 8.16 4.80 36 47.4 94.13 1.85 1.86 1.91 4.11 4.29 5.12 5.36 37 49.1 93.93 2.55 2.55 2.09 5.44 4.54 6.74 5.62 38 50.0 93.73 2.63 2.62 2.27 5.43 4.77 6.69 5.88 39 52.4 93.78 3.10 3.10 2.22 6.45 4.72 7.95 5.82 40 54.5 93.53 2.91 2.90 2.43 5.85 5.01 7.16 6.14 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 40 June 2014 WSE (ft) 95.49 96.44 96.78 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 57.0 93.03 3.34 3.31 2.83 6.39 5.57 7.74 6.76 42 59.5 92.83 3.32 3.28 2.99 6.25 5.79 7.55 7.00 43 61.8 92.83 2.89 2.86 2.99 5.44 5.79 6.57 7.00 44 63.8 92.93 2.65 2.62 2.91 5.02 5.68 6.07 6.88 45 66.0 93.03 2.54 2.52 2.83 4.86 5.57 5.88 6.76 46 67.6 92.83 2.09 2.06 2.99 3.93 5.79 4.74 7.00 47 69.1 93.03 2.43 2.41 2.83 4.65 5.57 5.63 6.76 48 70.6 93.13 1.39 1.38 2.76 2.68 5.46 3.25 6.64 49 72.8 93.53 2.28 2.27 2.43 4.59 5.01 5.61 6.14 50 74.5 93.63 2.07 2.06 2.35 4.22 4.89 5.17 6.01 51 76.7 94.03 1.75 1.76 2.00 3.81 4.41 4.73 5.49 52 77.4 94.03 1.42 1.42 2.00 3.09 4.41 3.84 5.49 53 78.2 94.43 -0.04 -0.04 1.61 -0.10 3.91 -0.12 4.94 54 79.0 94.78 1.79 1.86 1.24 5.07 3.44 6.53 4.44 55 80.2 94.88 0.55 0.58 1.12 1.67 3.30 2.17 4.29 56 81.6 95.03 0.78 0.84 0.93 2.74 3.08 3.60 4.06 57 83.1 95.13 0.44 0.49 0.79 1.79 2.93 2.37 3.90 58 84.6 95.68 1.24 2.04 1.81 2.97 59 86.3 96.71 0.29 0.48 60 88.5 96.98 61 88.5 97.39 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 41 June 2014 Table A.3-24. Summary of calibration details for original and revised input decks, Grant Creek, Transect 200. WSE (ft) 91.74 93.42 93.99 96.21 Disch (cfs) 0.89 8.93 14.83 63 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 97.59 2 0.1 97.22 3 1.0 96.65 4 2.0 94.89 -0.05 - 0.05 5 6.0 94.40 -0.06 - 0.06 6 7.5 94.18 -0.07 - 0.07 * 7 9.0 93.88 -0.01 -0.01 0.10 -0.07 - 0.07 8 10.0 93.28 0.02 0.02 0.08 0.08 0.08 0.32 0.32 9 12.0 92.78 0.04 0.04 0.06 0.06 0.06 0.20 0.20 10 16.0 91.88 0.04 0.04 0.05 0.05 0.05 0.14 0.14 11 19.0 91.68 0.00 0.00 0.03 d 0.04 0.04 0.04 0.09 0.09 12 21.0 91.68 0.00 0.00 0.02 0.02 0.03 0.03 0.03 0.08 0.08 13 24.0 91.48 0.02 0.01 0.08 0.08 0.10 0.11 0.11 0.27 0.27 14 27.0 91.48 0.01 0.01 0.05 0.05 0.06 0.07 0.06 0.16 0.16 15 28.4 91.68 0.01 0.01 0.07 0.07 0.09 0.10 0.10 0.24 0.24 16 30.4 91.58 0.01 0.01 0.04 0.04 0.05 0.05 0.05 0.13 0.13 17 33.2 91.58 0.06 0.05 0.40 0.38 0.49 0.54 0.52 1.31 1.31 18 36.0 90.98 0.12 0.11 0.35 0.34 0.42 0.46 0.45 1.05 1.05 19 38.0 90.38 0.08 0.08 0.18 0.18 0.21 0.23 0.23 0.51 0.51 20 40.0 90.18 0.08 0.08 0.19 0.18 0.21 0.23 0.23 0.50 0.50 * 21 42.0 90.38 0.12 0.15 0.27 0.34 0.31 0.35 0.44 0.75 0.75 22 42.1 97.55 23 42.2 97.55 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 42 June 2014 Table A.3-25. Summary of calibration details for original and revised input decks, Grant Creek, Transect 200, high flows. WSE (ft) 93.99 96.21 96.93 Disch (cfs) 14.83 62.55 89.36 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 97.59 2 0.1 97.22 3 1.0 96.65 0.24 0.07 4 2.0 94.89 0.65 0.17 0.92 0.25 5 6.0 94.40 0.80 0.21 1.06 0.29 6 7.5 94.18 0.86 0.22 1.12 0.30 7 9.0 93.88 -0.01 0.10 0.02 0.95 0.25 1.20 0.33 8 10.0 93.28 0.08 0.08 0.08 0.25 0.29 0.31 0.37 9 12.0 92.78 0.06 0.06 0.11 0.16 0.32 0.19 0.40 10 16.0 91.88 0.05 0.05 0.16 0.11 0.37 0.13 0.46 11 19.0 91.68 0.04 0.04 0.17 0.08 0.38 0.09 0.47 12 21.0 91.68 0.03 0.03 0.17 0.06 0.38 0.08 0.47 13 24.0 91.48 0.10 0.11 0.18 0.21 0.39 0.24 0.48 14 27.0 91.48 0.06 0.06 0.18 0.13 0.39 0.15 0.48 15 28.4 91.68 0.09 0.10 0.17 0.19 0.38 0.23 0.47 16 30.4 91.58 0.05 0.05 0.18 0.11 0.39 0.12 0.47 17 33.2 91.58 0.49 0.52 0.18 1.04 0.39 1.21 0.47 18 36.0 90.98 0.42 0.45 0.21 0.83 0.42 0.96 0.51 19 38.0 90.38 0.21 0.23 0.23 0.40 0.45 0.46 0.54 20 40.0 90.18 0.21 0.23 0.24 0.40 0.46 0.45 0.55 21 42.0 90.38 0.31 0.44 0.23 0.78 0.45 0.89 0.54 22 42.1 97.55 23 42.2 97.55 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 43 June 2014 Table A.3-26. Summary of calibration details for original and revised input decks, Grant Creek, Transect 210. WSE (ft) 94.01 94.40 94.63 96.08 96.77 Disch (cfs) 10 100 162 700 1000 Rv Pt Sta Elev Depth Depth Depth Depth Depth 1 0.0 96.61 0.16 2 2.0 96.32 0.45 3 5.0 96.18 0.59 4 6.9 95.64 0.44 1.13 5 9.0 95.03 1.05 1.74 6 11.0 95.19 0.89 1.58 7 13.0 95.16 0.92 1.61 8 14.4 95.09 0.99 1.68 9 15.3 95.32 0.76 1.45 10 16.2 94.77 1.31 2.00 11 17.1 94.56 0.07 1.52 2.21 12 17.9 94.53 0.10 1.55 2.24 13 18.1 94.51 0.12 1.57 2.26 14 19.4 94.17 0.23 0.46 1.91 2.60 15 20.8 94.21 0.19 0.42 1.87 2.56 16 21.4 93.61 0.40 0.79 1.02 2.47 3.16 17 22.0 94.04 0.36 0.59 2.04 2.73 18 22.5 93.63 0.38 0.77 1.00 2.45 3.14 19 23.1 94.08 0.32 0.55 2.00 2.69 20 23.7 93.73 0.28 0.67 0.90 2.35 3.04 21 24.5 93.97 0.04 0.43 0.66 2.11 2.80 22 25.5 93.90 0.11 0.50 0.73 2.18 2.87 23 26.5 94.10 0.30 0.53 1.98 2.67 24 27.2 94.29 0.11 0.34 1.79 2.48 25 27.9 94.52 0.11 1.56 2.25 26 29.0 94.69 1.39 2.08 27 30.0 95.06 1.02 1.71 28 31.0 95.55 0.53 1.22 29 32.0 96.02 0.06 0.75 30 33.0 96.27 0.50 31 34.0 96.62 0.15 32 35.0 96.92 33 35.6 97.17 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 44 June 2014 Table A.3-27. Summary of calibration details for original and revised input decks, Grant Creek, Transect 220. WSE (ft) 94.6 95.24 95.52 96.46 Disch (cfs) 10 100 180 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 99.06 2 0.1 98.78 3 3.0 98.35 4 4.8 97.86 5 5.0 97.79 6 5.5 95.55 0.68 0.97 * 7 6.0 95.00 0.16 0.22 0.28 0.32 0.45 0.93 1.32 8 6.9 94.70 0.34 0.34 0.48 0.55 0.55 1.35 1.35 9 8.1 94.65 2.25 2.25 3.10 3.55 3.55 8.53 8.53 10 10.0 94.30 0.50 0.50 2.84 2.84 3.57 4.11 4.11 8.87 8.87 11 11.2 94.15 0.50 0.50 2.38 2.38 2.92 3.36 3.36 7.04 7.03 12 12.0 94.05 0.79 0.79 3.51 3.50 4.25 4.90 4.90 10.06 10.05 13 12.8 94.00 0.86 0.86 3.72 3.71 4.48 5.17 5.16 10.52 10.51 14 14.5 94.15 0.65 0.65 3.10 3.10 3.81 4.39 4.39 9.18 9.17 15 15.8 94.05 0.68 0.68 3.04 3.03 3.68 4.24 4.24 8.71 8.70 16 17.0 93.85 0.62 0.62 2.51 2.51 2.98 3.44 3.44 6.84 6.84 17 18.0 93.75 0.52 0.52 2.02 2.02 2.38 2.75 2.75 5.39 5.39 18 19.5 93.75 0.97 0.97 3.74 3.74 4.41 5.09 5.09 9.99 9.98 19 20.8 93.85 0.69 0.69 2.76 2.76 3.28 3.79 3.79 7.53 7.52 20 23.2 93.85 0.75 0.75 3.03 3.03 3.60 4.16 4.15 8.26 8.26 21 24.5 93.95 0.54 0.54 2.26 2.26 2.71 3.13 3.13 6.31 6.31 22 25.9 94.05 0.27 0.27 1.19 1.19 1.44 1.66 1.66 3.41 3.41 23 27.2 94.15 0.67 0.67 3.22 3.22 3.95 4.55 4.55 9.52 9.51 24 28.6 93.95 0.42 0.42 1.78 1.78 2.14 2.47 2.47 4.98 4.98 25 30.5 94.05 0.79 0.79 3.51 3.50 4.25 4.90 4.90 10.06 10.05 26 32.4 94.05 0.62 0.62 2.75 2.75 3.33 3.84 3.84 7.88 7.88 27 33.5 94.05 0.47 0.47 2.09 2.09 2.53 2.92 2.92 5.99 5.98 28 35.1 94.25 0.36 0.36 1.93 1.93 2.40 2.76 2.76 5.90 5.90 29 36.1 94.65 2.47 2.47 3.40 3.89 3.89 9.36 9.35 30 37.5 94.65 1.83 1.83 2.52 2.88 2.88 6.94 6.93 31 38.5 94.75 1.13 1.13 1.63 1.86 1.86 4.67 4.67 32 39.9 94.85 0.78 0.78 1.19 1.35 1.35 3.58 3.58 33 40.9 94.65 1.51 1.50 2.07 2.37 2.37 5.70 5.69 34 42.6 94.95 0.64 0.64 1.07 1.21 1.21 3.42 3.42 35 44.6 95.15 0.63 0.63 1.74 1.94 1.94 6.65 6.64 36 46.5 95.25 0.68 0.75 0.75 2.99 2.98 37 48.1 95.45 0.32 0.31 0.31 2.60 2.60 38 49.7 95.45 1.08 1.04 1.04 8.78 8.77 39 50.8 95.45 0.41 0.40 0.40 3.33 3.33 40 53.5 94.90 0.16 0.16 0.26 0.30 0.30 0.81 0.81 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 45 June 2014 WSE (ft) 94.6 95.24 95.52 96.46 Disch (cfs) 10 100 180 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 55.0 94.85 0.25 0.25 0.39 0.44 0.44 1.17 1.17 42 56.1 94.85 1.14 1.14 1.74 1.98 1.98 5.24 5.24 43 58.5 94.65 1.32 1.32 1.81 2.07 2.07 4.98 4.98 44 59.9 94.85 0.52 0.52 0.80 0.91 0.91 2.41 2.41 45 61.0 94.65 0.46 0.46 0.63 0.72 0.72 1.73 1.73 46 62.8 94.90 0.37 0.37 0.59 0.67 0.67 47 61.1 95.55 1.28 1.28 48 62.9 97.12 49 65.9 97.28 50 65.9 97.90 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 46 June 2014 Table A.3-28. Summary of calibration details for original and revised input decks, Grant Creek, Transect 220, high flows. WSE (ft) 95.52 96.46 96.8 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 99.06 2 0.1 98.78 3 3.0 98.35 4 4.8 97.86 5 5.0 97.79 6 5.5 95.55 0.97 3.65 1.32 4.98 7 6.0 95.00 0.28 0.45 1.76 1.32 5.01 1.69 6.35 8 6.9 94.70 0.48 0.55 2.38 1.35 5.67 1.68 7.03 9 8.1 94.65 3.10 3.55 2.47 8.53 5.78 10.61 7.14 10 10.0 94.30 3.57 4.11 3.10 8.87 6.50 10.84 7.90 11 11.2 94.15 2.92 3.36 3.35 7.03 6.80 8.55 8.21 12 12.0 94.05 4.25 4.90 3.51 10.05 7.00 12.18 8.42 13 12.8 94.00 4.48 5.16 3.59 10.51 7.09 12.71 8.52 14 14.5 94.15 3.81 4.39 3.35 9.17 6.80 11.15 8.21 15 15.8 94.05 3.68 4.24 3.51 8.70 7.00 10.54 8.42 16 17.0 93.85 2.98 3.44 3.82 6.84 7.38 8.23 8.82 17 18.0 93.75 2.38 2.75 3.97 5.39 7.57 6.47 9.02 18 19.5 93.75 4.41 5.09 3.97 9.98 7.57 11.98 9.02 19 20.8 93.85 3.28 3.79 3.82 7.52 7.38 9.06 8.82 20 23.2 93.85 3.60 4.15 3.82 8.26 7.38 9.94 8.82 21 24.5 93.95 2.71 3.13 3.67 6.31 7.19 7.61 8.62 22 25.9 94.05 1.44 1.66 3.51 3.41 7.00 4.13 8.42 23 27.2 94.15 3.95 4.55 3.35 9.51 6.80 11.56 8.21 24 28.6 93.95 2.14 2.47 3.67 4.98 7.19 6.01 8.62 25 30.5 94.05 4.25 4.90 3.51 10.05 7.00 12.18 8.42 26 32.4 94.05 3.33 3.84 3.51 7.88 7.00 9.54 8.42 27 33.5 94.05 2.53 2.92 3.51 5.98 7.00 7.25 8.42 28 35.1 94.25 2.40 2.76 3.18 5.90 6.60 7.20 8.01 29 36.1 94.65 3.40 3.89 2.47 9.35 5.78 11.64 7.14 30 37.5 94.65 2.52 2.88 2.47 6.93 5.78 8.63 7.14 31 38.5 94.75 1.63 1.86 2.28 4.67 5.56 5.85 6.92 32 39.9 94.85 1.19 1.35 2.08 3.58 5.34 4.52 6.69 33 40.9 94.65 2.07 2.37 2.47 5.69 5.78 7.09 7.14 34 42.6 94.95 1.07 1.21 1.87 3.42 5.12 4.35 6.46 35 44.6 95.15 1.74 1.94 1.40 6.64 4.66 8.60 5.99 36 46.5 95.25 0.68 0.75 1.14 2.98 4.42 3.91 5.74 37 48.1 95.45 0.32 0.31 0.48 2.60 3.92 3.50 5.24 38 49.7 95.45 1.08 1.04 0.48 8.77 3.92 11.82 5.24 39 50.8 95.45 0.41 0.40 0.48 3.33 3.92 4.49 5.24 40 53.5 94.90 0.26 0.30 1.97 0.81 5.23 1.02 6.58 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 47 June 2014 WSE (ft) 95.52 96.46 96.8 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 55.0 94.85 0.39 0.44 2.08 1.17 5.34 1.48 6.69 42 56.1 94.85 1.74 1.98 2.08 5.24 5.34 6.60 6.69 43 58.5 94.65 1.81 2.07 2.47 4.98 5.78 6.20 7.14 44 59.9 94.85 0.80 0.91 2.08 2.41 5.34 3.04 6.69 45 61.0 94.65 0.63 0.72 2.47 1.73 5.78 2.16 7.14 46 62.8 94.90 0.59 0.67 1.97 47 61.1 95.55 1.28 3.65 1.75 4.98 48 62.9 97.12 49 65.9 97.28 50 65.9 97.90 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 48 June 2014 Table A.3-29. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, side channel. WSE (ft) 94.02 94.40 94.63 96.08 96.77 Disch (cfs) 10 100 162 700 1000 Rv Pt Sta Elev Depth Depth Depth Depth Depth 1 81.6 99.93 2 85.9 98.87 3 91.5 95.95 0.13 0.82 4 95.1 95.06 1.02 1.71 5 96.2 94.49 0.14 1.59 2.28 6 100.9 93.90 0.12 0.50 0.73 2.18 2.87 7 102.2 93.54 0.48 0.86 1.09 2.54 3.23 8 105.1 92.67 1.35 1.73 1.96 3.41 4.10 9 108.4 91.52 2.50 2.88 3.11 4.56 5.25 10 111.5 88.97 5.05 5.43 5.66 7.11 7.80 11 112.9 88.30 5.72 6.10 6.33 7.78 8.47 12 118.0 88.04 5.98 6.36 6.59 8.04 8.73 13 121.7 89.63 4.39 4.77 5.00 6.45 7.14 14 122.3 93.54 0.48 0.86 1.09 2.54 3.23 15 133.4 93.71 0.31 0.69 0.92 2.37 3.06 16 137.1 93.75 0.27 0.65 0.88 2.33 3.02 17 140.3 94.17 0.23 0.46 1.91 2.60 18 143.3 94.70 1.38 2.07 19 145.9 97.86 20 146.0 99.24 21 146.0 100.00 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 49 June 2014 Table A.3-30. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, main channel. WSE (ft) 94.69 95.49 95.82 96.84 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 100.75 2 0.1 99.41 3 2.2 95.85 -0.42 -0.62 4 2.3 96.48 -0.21 -0.32 * 5 2.5 94.85 -0.12 -0.18 -0.20 -0.22 -0.33 -0.66 -0.99 6 3.9 94.35 0.16 0.16 1.30 1.30 1.89 2.08 2.09 5.54 5.59 7 5.8 94.00 0.17 0.17 1.02 1.02 1.42 1.57 1.57 3.95 3.98 8 8.3 93.55 0.37 0.37 1.89 1.89 2.56 2.84 2.84 6.79 6.85 9 11.2 93.45 0.44 0.44 2.16 2.16 2.91 3.22 3.23 7.65 7.71 10 14.4 93.35 0.39 0.39 1.92 1.92 2.57 2.85 2.85 6.71 6.76 11 17.1 93.25 0.29 0.29 1.37 1.37 1.83 2.02 2.02 4.73 4.76 12 19.2 93.70 0.55 0.55 2.89 2.89 3.95 4.37 4.38 10.63 10.71 13 21.1 93.85 0.56 0.56 3.12 3.12 4.30 4.76 4.76 11.75 11.85 14 24.3 93.60 0.30 0.30 1.53 1.53 2.07 2.29 2.29 5.52 5.56 15 26.2 93.85 0.28 0.28 1.55 1.55 2.14 2.37 2.37 5.85 5.90 16 27.8 94.05 0.33 0.33 2.03 2.03 2.84 3.14 3.14 7.95 8.02 17 30.8 94.20 0.17 0.17 1.12 1.12 1.60 1.77 1.77 4.58 4.61 18 32.7 94.45 0.12 0.12 1.17 1.18 1.73 1.91 1.91 5.17 5.21 19 34.0 94.55 0.08 0.08 1.00 1.00 1.50 1.65 1.65 4.58 4.62 20 36.3 94.55 0.07 0.07 0.92 0.92 1.38 1.52 1.52 4.21 4.25 21 37.1 94.55 0.04 0.04 0.50 0.50 0.75 0.83 0.83 2.29 2.31 22 39.1 94.95 0.15 0.15 0.26 0.28 0.28 0.89 0.90 23 39.9 95.05 0.32 0.32 0.57 0.62 0.62 2.05 2.06 24 41.3 95.25 0.01 0.01 0.02 0.02 0.02 0.08 0.08 25 41.8 95.15 -0.02 -0.02 -0.03 -0.03 -0.03 -0.11 -0.11 26 42.7 95.45 0.02 0.02 0.13 0.14 0.14 0.63 0.63 27 45.8 95.65 0.08 0.08 0.57 0.57 28 49.0 95.65 0.23 0.23 0.23 1.61 1.62 29 49.9 95.65 0.22 0.22 0.22 1.54 1.55 30 52.6 95.85 1.36 1.37 31 56.1 95.85 1.36 1.37 32 59.1 95.85 1.36 1.37 * 33 61.5 95.65 -0.02 -0.02 -0.17 -0.14 -1.17 34 63.4 95.85 -0.12 -1.04 35 64.8 95.85 -0.12 -1.04 36 65.2 95.92 -0.12 -0.99 37 65.5 97.02 38 69.6 97.43 39 72.5 99.17 40 78.2 99.65 41 81.6 99.93 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 50 June 2014 Table A.3-31. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230 main channel, high flows. WSE (ft) 95.82 96.84 97.2 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 100.75 2 0.1 99.41 3 2.2 95.85 -0.62 2.70 -0.90 3.78 4 2.3 96.48 -0.32 1.38 -0.59 2.48 5 2.5 94.85 -0.20 -0.33 1.59 -0.99 4.32 -1.30 5.48 6 3.9 94.35 1.89 2.09 2.10 5.59 5.01 7.18 6.24 7 5.8 94.00 1.42 1.57 2.42 3.98 5.48 5.07 6.74 8 8.3 93.55 2.56 2.84 2.81 6.85 6.04 8.62 7.36 9 11.2 93.45 2.91 3.23 2.89 7.71 6.16 9.70 7.50 10 14.4 93.35 2.57 2.85 2.97 6.76 6.29 8.48 7.63 11 17.1 93.25 1.83 2.02 3.05 4.76 6.41 5.97 7.76 12 19.2 93.70 3.95 4.38 2.68 10.71 5.86 13.53 7.16 13 21.1 93.85 4.30 4.76 2.55 11.85 5.67 15.01 6.95 14 24.3 93.60 2.07 2.29 2.77 5.56 5.98 7.01 7.29 15 26.2 93.85 2.14 2.37 2.55 5.90 5.67 7.47 6.95 16 27.8 94.05 2.84 3.14 2.38 8.02 5.41 10.21 6.67 17 30.8 94.20 1.60 1.77 2.24 4.61 5.21 5.90 6.46 18 32.7 94.45 1.73 1.91 2.00 5.21 4.88 6.73 6.09 19 34.0 94.55 1.50 1.65 1.90 4.62 4.74 5.98 5.94 20 36.3 94.55 1.38 1.52 1.90 4.25 4.74 5.50 5.94 21 37.1 94.55 0.75 0.83 1.90 2.31 4.74 2.99 5.94 22 39.1 94.95 0.26 0.28 1.48 0.90 4.17 1.19 5.32 23 39.9 95.05 0.57 0.62 1.36 2.06 4.02 2.74 5.16 24 41.3 95.25 0.02 0.02 1.11 0.08 3.71 0.11 4.84 25 41.8 95.15 -0.03 -0.03 1.24 -0.11 3.87 -0.15 5.00 26 42.7 95.45 0.13 0.14 0.83 0.63 3.39 0.87 4.50 27 45.8 95.65 0.08 0.49 0.57 3.06 0.80 4.15 28 49.0 95.65 0.23 0.23 0.49 1.62 3.06 2.27 4.15 29 49.9 95.65 0.22 0.22 0.49 1.55 3.06 2.18 4.15 30 52.6 95.85 1.37 2.70 1.98 3.78 31 56.1 95.85 1.37 2.70 1.98 3.78 32 59.1 95.85 1.37 2.70 1.98 3.78 33 61.5 95.65 -0.02 -0.17 0.49 -1.17 3.06 -1.64 4.15 34 63.4 95.85 -1.04 2.70 -1.50 3.78 35 64.8 95.85 -1.04 2.70 -1.50 3.78 36 65.2 95.92 -0.99 2.58 -1.44 3.65 37 65.5 97.02 -0.39 0.97 38 69.6 97.43 39 72.5 99.17 40 78.2 99.65 41 81.6 99.93 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 51 June 2014 Table A.3-32. Summary of calibration details for original and revised input decks, Grant Creek, Transect 300. WSE (ft) 93.83 94.89 95.34 96.82 Disch (cfs) 0.17 1.71 3.07 11.94 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 99.49 2 0.1 99.49 3 0.8 99.18 4 1.2 98.59 5 1.9 98.31 6 3.2 97.68 7 4.8 97.25 8 5.5 96.83 9 6.0 96.62 0.01 0.01 10 6.8 96.63 0.01 0.01 11 7.1 96.49 0.01 0.01 12 8.9 96.48 0.01 0.01 13 9.0 95.81 0.02 0.02 14 9.4 95.66 0.02 0.02 15 11.0 95.64 0.02 0.02 16 11.8 95.33 0.00 0.00 0.02 0.02 17 13.0 95.13 0.00 0.00 0.02 0.02 18 14.4 94.98 0.01 0.01 0.03 0.03 19 15.9 94.83 0.00 0.00 0.01 0.01 0.03 0.03 20 17.5 94.63 0.00 0.00 0.01 0.01 0.03 0.03 21 19.0 94.63 0.00 0.00 0.01 0.01 0.03 0.03 22 21.3 94.63 0.00 0.00 0.01 0.01 0.03 0.03 23 23.0 94.90 0.01 0.01 0.03 0.03 24 25.0 94.68 0.00 0.00 0.01 0.01 0.03 0.03 25 27.0 94.58 0.00 0.00 0.01 0.01 0.03 0.03 26 29.0 94.53 0.01 0.01 0.01 0.01 0.03 0.03 27 31.0 94.38 0.01 0.01 0.01 0.01 0.03 0.03 28 32.3 94.43 0.01 0.01 0.01 0.01 0.03 0.03 29 33.0 93.48 0.00 0.00 0.01 0.01 0.02 0.02 0.04 0.04 30 35.0 93.73 0.00 0.00 0.01 0.01 0.02 0.02 0.04 0.04 31 36.4 93.53 0.00 0.00 0.01 0.01 0.02 0.02 0.02 0.04 0.04 32 38.0 93.43 0.00 0.00 0.01 0.01 0.02 0.02 0.02 0.04 0.04 33 39.0 93.93 0.01 0.01 0.01 0.01 0.01 0.02 0.02 34 40.0 93.23 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.02 0.02 35 42.0 93.08 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.02 0.02 36 43.1 93.08 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.02 0.02 37 44.5 93.13 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.02 0.02 38 46.0 93.23 0.01 0.01 0.02 0.02 0.03 0.03 0.03 0.06 0.06 39 47.5 93.03 0.01 0.01 0.02 0.02 0.03 0.03 0.03 0.05 0.05 40 49.9 92.83 0.00 0.00 0.01 0.01 0.02 0.01 0.01 0.03 0.03 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 52 June 2014 WSE (ft) 93.83 94.89 95.34 96.82 Disch (cfs) 0.17 1.71 3.07 11.94 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 51.6 92.93 0.00 0.00 0.01 0.01 0.02 0.01 0.01 0.03 0.03 42 54.6 93.23 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.02 0.02 43 56.2 93.13 0.00 0.00 0.01 0.01 0.02 0.02 0.02 0.04 0.04 44 58.4 93.43 0.07 0.07 0.23 0.23 0.35 0.32 0.32 0.67 0.67 45 60.6 93.23 0.03 0.03 0.07 0.07 0.11 0.10 0.10 0.21 0.21 46 63.3 93.59 0.01 0.01 0.06 0.06 0.09 0.09 0.19 0.19 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 53 June 2014 Table A.3-33. Summary of calibration details for original and revised input decks, Grant Creek, Transect 300, high flows. WSE (ft) 95.34 96.82 97.35 Disch (cfs) 3.07 11.94 17.06 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 99.49 2 0.1 99.49 3 0.8 99.18 4 1.2 98.59 5 1.9 98.31 6 3.2 97.68 7 4.8 97.25 0.00 0.01 8 5.5 96.83 0.01 0.03 9 6.0 96.62 0.01 0.01 0.02 0.03 10 6.8 96.63 0.01 0.01 0.02 0.03 11 7.1 96.49 0.01 0.02 0.02 0.04 12 8.9 96.48 0.01 0.02 0.02 0.04 13 9.0 95.81 0.02 0.04 0.03 0.05 14 9.4 95.66 0.02 0.04 0.03 0.06 15 11.0 95.64 0.02 0.04 0.03 0.06 16 11.8 95.33 0.00 0.00 0.02 0.05 0.03 0.06 17 13.0 95.13 0.00 0.01 0.02 0.05 0.03 0.07 18 14.4 94.98 0.01 0.01 0.03 0.05 0.03 0.07 19 15.9 94.83 0.01 0.02 0.03 0.06 0.04 0.07 20 17.5 94.63 0.01 0.02 0.03 0.06 0.04 0.08 21 19.0 94.63 0.01 0.02 0.03 0.06 0.04 0.08 22 21.3 94.63 0.01 0.02 0.03 0.06 0.04 0.08 23 23.0 94.90 0.01 0.02 0.03 0.06 0.04 0.07 24 25.0 94.68 0.01 0.02 0.03 0.06 0.04 0.08 25 27.0 94.58 0.01 0.02 0.03 0.06 0.04 0.08 26 29.0 94.53 0.01 0.02 0.03 0.06 0.04 0.08 27 31.0 94.38 0.01 0.03 0.03 0.07 0.04 0.08 28 32.3 94.43 0.01 0.03 0.03 0.06 0.04 0.08 29 33.0 93.48 0.02 0.04 0.04 0.08 0.05 0.10 30 35.0 93.73 0.02 0.04 0.04 0.08 0.05 0.09 31 36.4 93.53 0.02 0.02 0.04 0.04 0.08 0.05 0.10 32 38.0 93.43 0.02 0.02 0.04 0.04 0.08 0.05 0.10 33 39.0 93.93 0.01 0.01 0.03 0.02 0.07 0.03 0.09 34 40.0 93.23 0.01 0.01 0.04 0.02 0.08 0.02 0.10 35 42.0 93.08 0.01 0.01 0.05 0.02 0.09 0.02 0.10 36 43.1 93.08 0.01 0.01 0.05 0.02 0.09 0.02 0.10 37 44.5 93.13 0.01 0.01 0.05 0.02 0.09 0.02 0.10 38 46.0 93.23 0.03 0.03 0.04 0.06 0.08 0.07 0.10 39 47.5 93.03 0.03 0.03 0.05 0.05 0.09 0.07 0.10 40 49.9 92.83 0.02 0.01 0.05 0.03 0.09 0.03 0.11 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 54 June 2014 WSE (ft) 95.34 96.82 97.35 Disch (cfs) 3.07 11.94 17.06 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 51.6 92.93 0.02 0.01 0.05 0.03 0.09 0.03 0.11 42 54.6 93.23 0.01 0.01 0.04 0.02 0.08 0.02 0.10 43 56.2 93.13 0.02 0.02 0.05 0.04 0.09 0.04 0.10 44 58.4 93.43 0.35 0.32 0.04 0.67 0.08 0.82 0.10 45 60.6 93.23 0.11 0.10 0.04 0.21 0.08 0.25 0.10 46 63.3 93.59 0.09 0.04 0.19 0.08 0.23 0.09 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 55 June 2014 Table A.3-34. Summary of calibration details for original and revised input decks, Grant Creek, Transect 310. WSE (ft) 95.07 96.11 96.43 97.63 Disch (cfs) 10 100 165 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 100.50 2 0.0 99.99 3 0.8 99.55 4 1.8 98.45 * 5 2.1 96.42 -0.01 -0.40 -0.86 6 2.8 97.99 * 7 3.1 96.42 -0.01 -0.40 -0.86 * 8 3.9 95.62 -0.08 -0.18 -0.15 -0.15 -0.32 -0.57 -1.22 9 5.0 95.42 -0.04 -0.04 -0.06 -0.06 -0.06 -0.21 -0.21 10 6.3 95.32 -0.04 -0.04 -0.07 -0.07 -0.07 -0.23 -0.24 11 7.6 95.42 -0.05 -0.05 -0.08 -0.08 -0.08 -0.28 -0.28 12 8.9 95.32 -0.04 -0.04 -0.06 -0.06 -0.06 -0.20 -0.20 13 11.0 95.22 -0.05 -0.05 -0.08 -0.08 -0.08 -0.26 -0.26 14 13.0 95.12 -0.09 -0.09 -0.14 -0.14 -0.14 -0.44 -0.45 15 15.5 95.22 -0.15 -0.15 -0.24 -0.24 -0.24 -0.78 -0.79 16 17.1 95.32 -0.24 -0.24 -0.39 -0.39 -0.39 -1.31 -1.32 17 19.0 95.32 -0.28 -0.28 -0.44 -0.44 -0.44 -1.47 -1.49 18 21.0 95.12 -0.03 -0.03 -0.04 -0.04 -0.04 -0.13 -0.13 19 22.6 94.62 0.00 0.00 0.01 0.01 0.01 0.01 0.01 0.03 0.03 20 23.6 94.52 0.01 0.01 0.07 0.07 0.10 0.10 0.10 0.28 0.29 21 25.0 94.62 0.10 0.10 0.58 0.58 0.84 0.84 0.84 2.42 2.44 22 26.0 94.62 0.10 0.10 0.62 0.62 0.90 0.90 0.90 2.59 2.61 23 27.0 94.72 0.09 0.09 0.61 0.61 0.90 0.90 0.90 2.63 2.65 24 29.0 94.32 0.23 0.23 1.10 1.10 1.57 1.56 1.56 4.34 4.38 25 30.5 94.22 0.28 0.28 1.31 1.31 1.86 1.85 1.85 5.09 5.13 26 31.9 94.12 0.34 0.34 1.53 1.53 2.16 2.15 2.15 5.85 5.90 27 34.0 93.92 0.50 0.50 2.08 2.09 2.92 2.90 2.90 7.75 7.82 28 36.0 93.82 0.52 0.52 2.13 2.13 2.97 2.96 2.96 7.83 7.90 29 38.0 94.02 0.43 0.43 1.87 1.87 2.62 2.61 2.61 7.03 7.09 30 40.0 94.02 0.63 0.63 2.73 2.73 3.83 3.81 3.82 10.27 10.36 31 41.0 94.02 0.75 0.75 3.25 3.25 4.56 4.54 4.54 12.23 12.34 32 42.4 93.92 0.53 0.53 2.23 2.23 3.12 3.11 3.11 8.29 8.37 33 43.2 94.02 0.31 0.31 1.34 1.34 1.88 1.87 1.87 5.04 5.09 34 43.7 94.62 0.37 0.37 2.26 2.27 3.29 3.28 3.28 9.47 9.55 35 45.0 94.02 0.56 0.56 2.44 2.44 3.42 3.40 3.41 9.17 9.25 36 46.0 94.52 0.46 0.46 2.53 2.53 3.65 3.64 3.64 10.36 10.45 37 46.5 94.02 0.54 0.54 2.35 2.35 3.30 3.28 3.29 8.85 8.93 38 48.3 94.52 0.30 0.30 1.64 1.64 2.37 2.36 2.36 6.72 6.78 39 49.5 94.32 0.17 0.17 0.83 0.83 1.18 1.17 1.18 3.26 3.29 40 50.9 94.52 0.38 0.38 2.11 2.11 3.04 3.03 3.03 8.63 8.70 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 56 June 2014 WSE (ft) 95.07 96.11 96.43 97.63 Disch (cfs) 10 100 165 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 51.5 94.62 0.33 0.33 2.02 2.02 2.94 2.93 2.93 8.46 8.54 42 52.8 94.62 0.25 0.25 1.49 1.49 2.16 2.15 2.15 6.22 6.27 43 53.7 95.02 0.04 0.04 0.77 0.77 1.17 1.17 1.17 3.62 3.65 44 54.3 95.02 0.02 0.02 0.41 0.41 0.62 0.62 0.62 1.92 1.94 45 55.3 95.22 1.16 1.16 1.82 1.82 1.82 5.92 5.97 46 56.3 95.02 0.04 0.04 0.75 0.75 1.13 1.13 1.13 3.50 3.53 47 57.3 95.52 0.62 0.62 1.05 1.05 1.05 3.79 3.82 48 58.1 95.52 0.16 0.16 0.28 0.28 0.28 1.01 1.02 49 59.1 95.82 0.08 0.08 0.17 0.17 0.17 0.73 0.73 50 60.0 96.02 0.04 0.04 0.14 0.14 0.14 0.73 0.73 * 51 61.2 96.22 -0.04 -0.04 -0.17 -0.30 -1.29 52 62.4 96.32 -0.03 -0.11 -0.29 -1.22 53 63.7 96.55 -0.25 -1.07 54 65.1 96.93 -0.19 -0.80 55 66.3 98.91 56 68.6 98.61 57 71.2 99.21 58 73.0 98.94 59 75.6 98.94 60 78.0 98.73 61 80.0 99.43 62 82.0 98.95 63 84.0 98.28 64 86.0 97.88 65 88.0 97.74 66 90.0 97.70 67 92.0 98.09 68 94.0 98.40 69 96.6 98.21 70 96.6 100.84 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 57 June 2014 Table A.3-35. Summary of calibration details for original and revised input decks, Grant Creek, Transect 310, high flows. WSE (ft) 96.43 97.63 98.00 Disch (cfs) 165 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 100.50 2 0.0 99.99 3 0.8 99.55 4 1.8 98.45 5 2.1 96.42 -0.86 2.25 -1.24 3.14 6 2.8 97.99 -0.04 0.09 7 3.1 96.42 -0.86 2.25 -1.24 3.14 8 3.9 95.62 -0.15 -0.32 0.98 -1.22 3.20 -1.65 4.17 9 5.0 95.42 -0.06 -0.06 1.14 -0.21 3.41 -0.28 4.40 10 6.3 95.32 -0.07 -0.07 1.21 -0.24 3.51 -0.32 4.51 11 7.6 95.42 -0.08 -0.08 1.14 -0.28 3.41 -0.37 4.40 12 8.9 95.32 -0.06 -0.06 1.21 -0.20 3.51 -0.27 4.51 13 11.0 95.22 -0.08 -0.08 1.29 -0.26 3.61 -0.35 4.63 14 13.0 95.12 -0.14 -0.14 1.36 -0.45 3.71 -0.59 4.74 15 15.5 95.22 -0.24 -0.24 1.29 -0.79 3.61 -1.05 4.63 16 17.1 95.32 -0.39 -0.39 1.21 -1.32 3.51 -1.76 4.51 17 19.0 95.32 -0.44 -0.44 1.21 -1.49 3.51 -1.98 4.51 18 21.0 95.12 -0.04 -0.04 1.36 -0.13 3.71 -0.17 4.74 19 22.6 94.62 0.01 0.01 1.69 0.03 4.19 0.04 5.27 20 23.6 94.52 0.10 0.10 1.75 0.29 4.28 0.37 5.38 21 25.0 94.62 0.84 0.84 1.69 2.44 4.19 3.18 5.27 22 26.0 94.62 0.90 0.90 1.69 2.61 4.19 3.41 5.27 23 27.0 94.72 0.90 0.90 1.62 2.65 4.10 3.47 5.17 24 29.0 94.32 1.57 1.56 1.87 4.38 4.47 5.67 5.58 25 30.5 94.22 1.86 1.85 1.93 5.13 4.56 6.63 5.68 26 31.9 94.12 2.16 2.15 1.99 5.90 4.65 7.61 5.78 27 34.0 93.92 2.92 2.90 2.10 7.82 4.82 10.04 5.98 28 36.0 93.82 2.97 2.96 2.15 7.90 4.91 10.13 6.08 29 38.0 94.02 2.62 2.61 2.04 7.09 4.73 9.12 5.88 30 40.0 94.02 3.83 3.82 2.04 10.36 4.73 13.34 5.88 31 41.0 94.02 4.56 4.54 2.04 12.34 4.73 15.88 5.88 32 42.4 93.92 3.12 3.11 2.10 8.37 4.82 10.75 5.98 33 43.2 94.02 1.88 1.87 2.04 5.09 4.73 6.55 5.88 34 43.7 94.62 3.29 3.28 1.69 9.55 4.19 12.45 5.27 35 45.0 94.02 3.42 3.41 2.04 9.25 4.73 11.91 5.88 36 46.0 94.52 3.65 3.64 1.75 10.45 4.28 13.58 5.38 37 46.5 94.02 3.30 3.29 2.04 8.93 4.73 11.49 5.88 38 48.3 94.52 2.37 2.36 1.75 6.78 4.28 8.82 5.38 39 49.5 94.32 1.18 1.18 1.87 3.29 4.47 4.26 5.58 40 50.9 94.52 3.04 3.03 1.75 8.70 4.28 11.31 5.38 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 58 June 2014 WSE (ft) 96.43 97.63 98.00 Disch (cfs) 165 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 51.5 94.62 2.94 2.93 1.69 8.54 4.19 11.13 5.27 42 52.8 94.62 2.16 2.15 1.69 6.27 4.19 8.17 5.27 43 53.7 95.02 1.17 1.17 1.43 3.65 3.81 4.82 4.85 44 54.3 95.02 0.62 0.62 1.43 1.94 3.81 2.55 4.85 45 55.3 95.22 1.82 1.82 1.29 5.97 3.61 7.93 4.63 46 56.3 95.02 1.13 1.13 1.43 3.53 3.81 4.65 4.85 47 57.3 95.52 1.05 1.05 1.06 3.82 3.30 5.14 4.28 48 58.1 95.52 0.28 0.28 1.06 1.02 3.30 1.37 4.28 49 59.1 95.82 0.17 0.17 0.81 0.73 2.98 1.00 3.93 50 60.0 96.02 0.14 0.14 0.62 0.73 2.75 1.01 3.68 51 61.2 96.22 -0.04 -0.17 0.40 -1.29 2.52 -1.81 3.43 52 62.4 96.32 -0.11 0.25 -1.22 2.40 -1.74 3.30 53 63.7 96.55 -1.07 2.11 -1.58 2.99 54 65.1 96.93 -0.80 1.57 -1.29 2.44 55 66.3 98.91 56 68.6 98.61 57 71.2 99.21 58 73.0 98.94 59 75.6 98.94 60 78.0 98.73 61 80.0 99.43 62 82.0 98.95 63 84.0 98.28 64 86.0 97.88 -0.29 0.56 65 88.0 97.74 -0.50 0.94 66 90.0 97.70 -0.55 1.04 67 92.0 98.09 68 94.0 98.40 69 96.6 98.21 70 96.6 100.84 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 59 June 2014 Table A.3-36. Summary of calibration details for original and revised input decks, Grant Creek, Transect 320. WSE (ft) 95.83 96.15 96.21 96.81 Disch (cfs) 1.58 15.81 20.96 111 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 100.50 2 0.0 100.03 3 2.0 99.32 4 5.0 98.70 5 7.4 97.81 6 10.0 97.58 7 11.3 96.99 * 8 12.1 95.37 0.02 0.05 0.10 0.26 0.12 0.12 0.31 0.34 0.89 9 14.6 95.11 0.10 0.10 0.49 0.48 0.59 0.58 0.58 1.58 1.54 10 16.8 94.89 0.32 0.32 1.53 1.51 1.83 1.81 1.79 4.72 4.60 11 17.5 95.01 0.34 0.33 1.64 1.62 1.97 1.95 1.93 5.19 5.05 12 18.7 95.02 0.25 0.24 1.20 1.19 1.45 1.43 1.42 3.82 3.73 13 20.6 95.91 0.17 0.17 0.24 0.23 0.23 0.99 0.96 14 21.4 95.49 0.35 0.34 2.12 2.10 2.63 2.59 2.57 7.89 7.69 15 22.3 95.86 0.20 0.20 0.27 0.26 0.26 1.04 1.02 16 22.9 95.23 0.16 0.16 0.85 0.84 1.03 1.02 1.01 2.84 2.77 17 24.0 95.44 -0.03 -0.03 -0.18 -0.18 -0.22 -0.22 -0.21 -0.65 -0.63 18 25.2 95.35 0.03 0.03 0.18 0.18 0.22 0.22 0.22 0.63 0.61 19 26.2 95.59 0.22 0.21 1.50 1.48 1.88 1.85 1.83 5.91 5.75 20 27.1 95.60 0.25 0.25 1.77 1.75 2.22 2.19 2.16 7.01 6.83 21 28.3 95.85 1.60 1.59 2.15 2.10 2.08 8.22 8.01 22 29.9 95.43 0.22 0.22 1.26 1.25 1.56 1.54 1.52 4.57 4.46 23 31.3 95.35 0.06 0.06 0.32 0.32 0.39 0.39 0.38 1.11 1.08 24 33.0 95.49 0.05 0.05 0.31 0.31 0.39 0.38 0.38 1.17 1.14 25 33.5 95.83 0.44 0.43 0.58 0.57 0.56 2.17 2.11 26 35.0 95.29 0.14 0.14 0.75 0.75 0.92 0.91 0.90 2.58 2.51 27 37.8 95.61 0.14 0.14 0.98 0.98 1.24 1.22 1.21 3.94 3.84 28 37.8 95.59 0.02 0.02 0.17 0.17 0.21 0.21 0.20 0.66 0.64 29 39.0 95.57 0.01 0.01 0.06 0.06 0.07 0.07 0.07 0.22 0.21 * 30 41.6 95.58 0.01 0.06 0.07 0.22 0.13 31 42.8 95.78 0.00 0.00 0.06 0.06 0.08 0.08 0.08 0.29 0.28 32 43.3 95.89 0.02 0.02 0.03 0.03 0.03 0.12 0.12 33 43.6 96.74 0.02 0.02 34 45.9 96.70 0.03 0.03 35 46.0 96.19 -0.01 0.00 -0.24 0.09 36 46.8 95.99 -0.04 -0.06 -0.06 -0.28 * 37 47.0 95.96 -0.04 -0.06 -0.29 -0.22 * 38 49.0 95.94 -0.05 -0.07 -0.30 -0.21 * 39 49.3 95.94 -0.04 0.16 -0.06 -0.06 0.22 -0.26 0.95 * 40 50.0 95.98 -0.04 -0.05 -0.25 0.71 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 60 June 2014 WSE (ft) 95.83 96.15 96.21 96.81 Disch (cfs) 1.58 15.81 20.96 111 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev * 41 51.0 96.16 -0.02 -0.21 0.71 42 51.3 96.55 -0.12 0.43 43 53.5 96.59 -0.10 0.38 44 55.1 96.77 -0.03 0.12 45 57.3 96.93 46 58.8 97.33 47 59.8 97.51 48 60.4 97.37 49 60.4 98.68 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 61 June 2014 Table A.3-37. Summary of calibration details for original and revised input decks, Grant Creek, Transect 320, high flows. WSE (ft) 20.98 96.81 97.01 Disch (cfs) 20.98 111 158.14 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 100.50 2 0.0 100.03 3 2.0 99.32 4 5.0 98.70 5 7.4 97.81 6 10.0 97.58 7 11.3 96.99 0.05 0.14 8 12.1 95.37 0.12 0.31 0.95 0.89 2.61 1.10 3.16 9 14.6 95.11 0.59 0.58 1.14 1.54 2.91 1.88 3.49 10 16.8 94.89 1.83 1.79 1.28 4.60 3.16 5.57 3.75 11 17.5 95.01 1.97 1.93 1.20 5.05 3.03 6.14 3.61 12 18.7 95.02 1.45 1.42 1.20 3.73 3.01 4.53 3.60 13 20.6 95.91 0.24 0.23 0.48 0.96 1.90 1.25 2.42 14 21.4 95.49 2.63 2.57 0.85 7.69 2.46 9.56 3.00 15 22.3 95.86 0.27 0.26 0.53 1.02 1.97 1.31 2.49 16 22.9 95.23 1.03 1.01 1.05 2.77 2.77 3.40 3.34 17 24.0 95.44 -0.22 -0.21 0.89 -0.63 2.52 -0.78 3.07 18 25.2 95.35 0.22 0.22 0.96 0.61 2.63 0.75 3.19 19 26.2 95.59 1.88 1.83 0.77 5.75 2.33 7.21 2.87 20 27.1 95.60 2.22 2.16 0.76 6.83 2.32 8.56 2.85 21 28.3 95.85 2.15 2.08 0.54 8.01 1.99 10.28 2.50 22 29.9 95.43 1.56 1.52 0.90 4.46 2.53 5.52 3.08 23 31.3 95.35 0.39 0.38 0.96 1.08 2.63 1.34 3.19 24 33.0 95.49 0.39 0.38 0.85 1.14 2.46 1.42 3.00 25 33.5 95.83 0.58 0.56 0.56 2.11 2.01 2.71 2.53 26 35.0 95.29 0.92 0.90 1.01 2.51 2.70 3.09 3.26 27 37.8 95.61 1.24 1.21 0.76 3.84 2.31 4.81 2.84 28 37.8 95.59 0.21 0.20 0.77 0.64 2.33 0.81 2.87 29 39.0 95.57 0.07 0.07 0.79 0.21 2.36 0.27 2.90 30 41.6 95.58 0.13 1.42 0.18 1.92 31 42.8 95.78 0.08 0.08 0.61 0.28 2.08 0.35 2.60 32 43.3 95.89 0.03 0.03 0.50 0.12 1.93 0.15 2.45 33 43.6 96.74 0.02 0.35 0.06 0.94 34 45.9 96.70 0.03 0.47 0.06 1.03 35 46.0 96.19 0.00 0.08 0.09 1.48 0.12 1.98 36 46.8 95.99 -0.06 -0.06 0.39 -0.28 1.79 -0.36 2.30 37 47.0 95.96 -0.22 1.42 -0.30 1.92 38 49.0 95.94 -0.21 1.39 -0.30 1.88 39 49.3 95.94 -0.06 0.22 0.44 0.95 1.86 1.24 2.37 40 50.0 95.98 0.71 1.39 0.98 1.88 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 62 June 2014 WSE (ft) 20.98 96.81 97.01 Disch (cfs) 20.98 111 158.14 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 51.0 96.16 0.71 1.39 0.98 1.88 42 51.3 96.55 0.43 0.83 0.70 1.34 43 53.5 96.59 0.38 0.74 0.66 1.26 44 55.1 96.77 0.12 0.24 0.45 0.86 45 57.3 96.93 0.21 0.40 46 58.8 97.33 47 59.8 97.51 48 60.4 97.37 49 60.4 98.68 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 63 June 2014 Table A.3-38. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, secondary channel. WSE (ft) 95.67 96.05 96.49 96.67 Disch (cfs) 0.13 1.27 5.71 8.90 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 82.2 97.95 2 85.2 98.04 3 88.2 97.76 * 4 90.7 96.48 0.06 0.03 0.38 0.19 5 91.2 96.60 0.20 0.10 * 6 91.7 96.28 0.35 * 0.17 0.62 0.30 * 7 92.2 96.28 0.35 * 0.17 0.62 0.30 8 92.7 96.18 0.50 0.46 0.46 0.72 0.73 9 93.2 96.28 0.10 0.09 0.09 0.16 0.17 10 93.7 95.73 0.04 0.04 0.13 0.13 0.17 0.18 11 94.2 95.73 0.04 0.04 0.13 0.13 0.17 0.18 12 95.2 95.48 0.01 0.01 0.06 0.06 0.16 0.16 0.20 0.21 13 95.7 95.68 0.04 0.04 0.15 0.13 0.14 0.18 0.18 14 96.2 95.58 0.01 0.01 0.10 0.10 0.30 0.27 0.27 0.35 0.36 15 96.7 95.58 0.03 0.03 0.22 0.22 0.68 0.61 0.62 0.80 0.82 16 97.2 95.48 0.03 0.03 0.17 0.17 0.50 0.45 0.45 0.58 0.59 17 97.7 95.58 0.02 0.02 0.18 0.18 0.56 0.50 0.51 0.66 0.67 18 98.1 95.68 0.15 0.15 0.52 0.47 0.47 0.62 0.63 19 98.7 95.58 0.02 0.02 0.17 0.17 0.53 0.47 0.48 0.62 0.64 20 99.0 95.48 0.03 0.03 0.18 0.18 0.53 0.47 0.48 0.61 0.63 21 99.4 95.18 0.09 0.09 0.32 0.32 0.84 0.75 0.76 0.95 0.97 22 99.8 95.08 0.08 0.08 0.29 0.29 0.74 0.66 0.67 0.83 0.85 23 100.2 95.48 0.05 0.05 0.25 0.25 0.73 0.65 0.66 0.85 0.86 24 100.5 95.48 0.05 0.05 0.25 0.25 0.74 0.66 0.67 0.86 0.88 25 100.8 95.23 0.11 0.11 0.42 0.42 1.11 0.99 1.01 1.26 1.29 26 101.2 95.28 0.11 0.11 0.44 0.44 1.18 1.05 1.07 1.34 1.37 27 101.5 95.23 0.13 0.13 0.50 0.50 1.33 1.19 1.21 1.51 1.54 28 101.9 95.48 0.08 0.08 0.42 0.42 1.22 1.09 1.11 1.41 1.45 29 102.2 95.48 0.05 0.05 0.25 0.25 0.73 0.65 0.66 0.85 0.86 30 102.5 95.28 0.05 0.05 0.21 0.21 0.57 0.51 0.52 0.65 0.66 31 102.9 95.28 0.03 0.03 0.13 0.13 0.34 0.30 0.31 0.39 0.40 32 103.2 95.18 0.03 0.03 0.10 0.10 0.27 0.24 0.24 0.31 0.31 33 103.5 95.18 0.02 0.02 0.08 0.08 0.20 0.18 0.18 0.23 0.23 34 103.9 95.33 0.01 0.01 0.02 0.02 0.06 0.05 0.05 0.07 0.07 35 104.2 95.43 0.01 0.01 0.03 0.03 0.08 0.07 0.07 0.09 0.09 36 105.2 96.08 0.16 0.15 0.15 0.21 0.22 * 37 106.2 96.06 0.15 0.02 0.22 0.25 * 38 106.5 96.38 0.06 0.13 0.23 * 39 106.8 96.48 0.10 0.02 0.10 0.19 40 107.0 97.31 * 41 109.2 96.17 Total 2 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 64 June 2014 Table A.3-39. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, second channel, high flows. WSE (ft) 96.49 96.67 96.84 Disch (cfs) 5.71 8.90 12.72 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 82.2 97.95 2 85.2 98.04 3 88.2 97.76 4 90.7 96.48 0.03 0.03 0.19 0.18 0.32 0.30 5 91.2 96.60 0.10 0.09 0.24 0.23 6 91.7 96.28 0.17 0.16 0.30 0.28 0.43 0.40 7 92.2 96.28 0.17 0.16 0.30 0.28 0.43 0.40 8 92.7 96.18 0.50 0.46 0.21 0.73 0.33 1.01 0.45 9 93.2 96.28 0.10 0.09 0.16 0.17 0.28 0.24 0.40 10 93.7 95.73 0.13 0.38 0.18 0.51 0.22 0.64 11 94.2 95.73 0.13 0.38 0.18 0.51 0.22 0.64 12 95.2 95.48 0.16 0.46 0.21 0.60 0.25 0.73 13 95.7 95.68 0.15 0.14 0.40 0.18 0.53 0.23 0.66 14 96.2 95.58 0.30 0.27 0.43 0.36 0.56 0.45 0.70 15 96.7 95.58 0.68 0.62 0.43 0.82 0.56 1.01 0.70 16 97.2 95.48 0.50 0.45 0.46 0.59 0.60 0.73 0.73 17 97.7 95.58 0.56 0.51 0.43 0.67 0.56 0.83 0.70 18 98.1 95.68 0.52 0.47 0.40 0.63 0.53 0.79 0.66 19 98.7 95.58 0.53 0.48 0.43 0.64 0.56 0.79 0.70 20 99.0 95.48 0.53 0.48 0.46 0.63 0.60 0.77 0.73 21 99.4 95.18 0.84 0.76 0.55 0.97 0.69 1.18 0.84 22 99.8 95.08 0.74 0.67 0.58 0.85 0.72 1.02 0.87 23 100.2 95.48 0.73 0.66 0.46 0.86 0.60 1.07 0.73 24 100.5 95.48 0.74 0.67 0.46 0.88 0.60 1.08 0.73 25 100.8 95.23 1.11 1.01 0.53 1.29 0.68 1.56 0.82 26 101.2 95.28 1.18 1.07 0.52 1.37 0.66 1.67 0.80 27 101.5 95.23 1.33 1.21 0.53 1.54 0.68 1.87 0.82 28 101.9 95.48 1.22 1.11 0.46 1.45 0.60 1.78 0.73 29 102.2 95.48 0.73 0.66 0.46 0.86 0.60 1.07 0.73 30 102.5 95.28 0.57 0.52 0.52 0.66 0.66 0.81 0.80 31 102.9 95.28 0.34 0.31 0.52 0.40 0.66 0.48 0.80 32 103.2 95.18 0.27 0.24 0.55 0.31 0.69 0.38 0.84 33 103.5 95.18 0.20 0.18 0.55 0.23 0.69 0.28 0.84 34 103.9 95.33 0.06 0.05 0.51 0.07 0.65 0.09 0.79 35 104.2 95.43 0.08 0.07 0.48 0.09 0.61 0.12 0.75 36 105.2 96.08 0.16 0.15 0.33 0.22 0.45 0.29 0.58 37 106.2 96.06 0.02 0.25 0.25 0.37 0.44 0.50 38 106.5 96.38 0.26 0.23 0.38 0.42 0.50 39 106.8 96.48 0.10 0.11 0.19 0.23 0.38 0.35 40 107.0 97.31 0.03 0.18 0.30 41 109.2 96.17 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 65 June 2014 Table A.3-40. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, tertiary channel. WSE (ft) 95.67 96.05 96.49 96.67 Disch (cfs) 0.13 1.27 5.71 8.90 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 107.0 97.31 * 2 109.2 96.17 0.13 0.17 0.16 * 3 112.2 95.98 0.19 0.20 0.22 4 112.6 96.45 0.11 0.27 5 112.8 95.85 0.06 0.15 0.66 0.22 * 0.57 0.22 0.53 6 113.0 95.75 0.01 0.01 0.06 0.15 0.40 0.14 * 0.35 0.13 0.31 7 113.2 96.05 0.24 0.08 0.21 0.09 0.22 8 113.4 96.05 0.24 0.08 0.21 0.09 0.22 9 113.6 96.05 0.24 0.08 0.21 0.09 0.22 10 113.7 96.45 0.00 0.00 11 115.2 96.97 12 117.4 96.64 0.00 0.00 13 117.7 96.45 0.00 0.00 14 117.8 95.65 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.01 15 118.0 95.65 0.00 0.00 0.00 0.00 0.01 0.00 0.01 0.00 0.01 16 118.2 95.65 0.00 0.00 0.00 0.00 0.01 0.00 0.01 0.00 0.01 17 118.4 95.55 0.00 0.00 0.00 0.01 0.01 0.00 0.01 0.00 0.01 18 118.6 95.55 0.00 0.00 0.00 0.01 0.01 0.00 0.01 0.00 0.01 19 118.8 95.45 0.00 0.00 0.00 0.01 0.01 0.00 0.01 0.00 0.01 20 119.0 95.40 0.00 0.00 0.00 0.01 0.01 0.00 0.01 0.00 0.01 21 119.2 95.35 0.01 0.01 0.04 0.09 0.05 0.13 0.04 0.11 22 119.4 95.45 0.00 0.01 0.03 0.08 0.05 0.12 0.04 0.10 23 119.5 95.30 0.01 0.01 0.04 0.10 0.05 0.13 0.04 0.11 24 119.6 95.45 0.00 0.01 0.03 0.08 0.05 0.12 0.04 0.10 25 119.8 95.45 0.00 0.01 0.03 0.08 0.14 0.05 0.12 0.04 0.10 26 120.0 95.45 0.01 0.02 0.06 0.15 0.25 0.08 0.22 0.07 0.18 27 120.2 95.45 0.01 0.02 0.08 0.19 0.32 0.11 * 0.28 0.09 0.23 28 120.4 95.50 0.01 0.02 0.08 0.18 0.33 0.11 * 0.29 0.10 0.24 29 120.6 95.55 0.02 0.04 0.14 0.34 0.63 0.21 * 0.55 0.19 0.47 30 120.7 95.42 0.02 0.05 0.17 0.42 0.76 0.23 * 0.66 0.20 0.56 31 120.8 95.50 0.02 0.05 0.17 0.44 0.82 0.26 * 0.71 0.23 0.61 32 121.0 95.55 0.02 0.06 0.18 0.48 0.91 0.28 * 0.79 0.25 0.67 33 121.2 95.55 0.02 0.07 0.20 0.55 1.03 0.31 * 0.89 0.27 0.76 34 121.4 95.55 0.03 0.05 0.22 0.43 0.92 0.35 * 0.80 0.31 0.70 35 121.6 95.65 0.02 0.05 0.18 0.46 0.99 0.31 * 0.86 0.28 0.75 36 121.8 95.65 0.02 0.02 0.19 0.26 0.68 0.33 * 0.59 0.31 0.53 37 122.0 95.75 0.01 0.02 0.10 0.21 0.67 0.23 * 0.58 0.22 0.53 38 122.2 95.80 0.01 0.09 0.23 * 0.22 * 39 125.2 95.37 0.03 0.24 0.32 * 0.28 40 128.2 97.48 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 66 June 2014 WSE (ft) 95.67 96.05 96.49 96.67 Disch (cfs) 0.13 1.27 5.71 8.90 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 131.2 97.66 42 134.2 97.53 43 137.2 97.68 44 140.2 97.98 45 143.2 98.02 46 144.8 98.24 47 144.8 100.28 Total 15 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 67 June 2014 Table A.3-41. Summary of calibration details for original and revised input decks, Grant Creek, Transect 330, tertiary channel, high flows. WSE (ft) 96.45 96.80 97.34 Disch (cfs) 1.6 97 97.34 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 107.0 97.31 0.03 0.02 2 109.2 96.17 0.16 0.08 0.23 0.13 3 112.2 95.98 0.22 0.11 0.25 0.14 4 112.6 96.45 0.27 0.14 0.27 0.15 5 112.8 95.85 0.66 0.57 0.26 0.53 0.27 0.38 0.21 6 113.0 95.75 0.40 0.35 0.29 0.31 0.29 0.22 0.22 7 113.2 96.05 0.24 0.21 0.20 0.22 0.23 0.16 0.19 8 113.4 96.05 0.24 0.21 0.20 0.22 0.23 0.16 0.19 9 113.6 96.05 0.24 0.21 0.20 0.22 0.23 0.16 0.19 10 113.7 96.45 0.00 0.14 0.00 0.15 11 115.2 96.97 0.00 0.08 12 117.4 96.64 0.00 0.08 0.00 0.13 13 117.7 96.45 0.00 0.14 0.00 0.15 14 117.8 95.65 0.01 0.32 0.01 0.30 0.01 0.23 15 118.0 95.65 0.01 0.01 0.32 0.01 0.30 0.01 0.23 16 118.2 95.65 0.01 0.01 0.32 0.01 0.30 0.01 0.23 17 118.4 95.55 0.01 0.01 0.35 0.01 0.32 0.00 0.24 18 118.6 95.55 0.01 0.01 0.35 0.01 0.32 0.00 0.24 19 118.8 95.45 0.01 0.01 0.37 0.01 0.34 0.00 0.25 20 119.0 95.40 0.01 0.01 0.38 0.01 0.35 0.00 0.25 21 119.2 95.35 0.13 0.40 0.11 0.36 0.07 0.26 22 119.4 95.45 0.12 0.37 0.10 0.34 0.07 0.25 23 119.5 95.30 0.13 0.41 0.11 0.36 0.07 0.26 24 119.6 95.45 0.12 0.37 0.10 0.34 0.07 0.25 25 119.8 95.45 0.14 0.12 0.37 0.10 0.34 0.07 0.25 26 120.0 95.45 0.25 0.22 0.37 0.18 0.34 0.12 0.25 27 120.2 95.45 0.32 0.28 0.37 0.23 0.34 0.15 0.25 28 120.4 95.50 0.33 0.29 0.36 0.24 0.33 0.16 0.24 29 120.6 95.55 0.63 0.55 0.35 0.47 0.32 0.31 0.24 30 120.8 95.50 0.76 0.66 0.36 0.56 0.33 0.37 0.24 31 121.0 95.55 0.82 0.71 0.35 0.61 0.32 0.41 0.24 32 121.2 95.55 0.91 0.79 0.35 0.67 0.32 0.45 0.24 33 121.4 95.55 1.03 0.89 0.35 0.76 0.32 0.51 0.24 34 121.6 95.65 0.92 0.80 0.32 0.70 0.30 0.47 0.23 35 121.8 95.65 0.99 0.86 0.32 0.75 0.30 0.51 0.23 36 122.0 95.75 0.68 0.59 0.29 0.53 0.29 0.37 0.22 37 122.2 95.80 0.67 0.58 0.28 0.53 0.28 0.37 0.21 38 122.1 96.79 0.14 0.08 39 122.2 95.33 40 125.2 95.37 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 68 June 2014 WSE (ft) 96.45 96.80 97.34 Disch (cfs) 1.6 97 97.34 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 128.2 97.48 42 131.2 97.66 43 134.2 97.53 44 137.2 97.68 45 140.2 97.98 46 143.2 98.02 47 144.8 98.24 48 144.8 100.28 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 69 June 2014 Table A.3-42. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, main channel. WSE (ft) 96.44 97.04 97.94 98.57 Disch (cfs) 1.5 15.06 59.41 105 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 7.0 99.17 2 1.7 98.55 0.00 0.01 3 2.7 98.49 0.00 0.02 4 4.2 98.13 0.00 0.06 5 5.2 98.00 0.01 0.07 6 6.2 97.88 0.00 0.02 0.01 0.08 7 7.2 97.72 0.00 0.04 0.01 0.10 8 8.2 97.63 0.00 0.05 0.01 0.10 9 9.2 97.52 0.00 0.06 0.01 0.11 10 10.2 97.55 0.00 0.05 0.01 0.11 11 11.2 97.36 0.01 0.07 0.01 0.12 12 12.2 97.32 0.01 0.07 0.01 0.12 13 13.2 97.28 0.01 0.08 0.01 0.13 14 14.2 97.35 0.01 0.07 0.01 0.12 15 15.2 97.21 0.01 0.08 0.01 0.13 16 16.2 97.16 0.01 0.08 0.01 0.13 17 17.2 97.05 0.01 0.09 0.01 0.14 18 18.2 97.17 0.01 0.08 0.01 0.13 19 19.7 97.26 0.01 0.08 0.01 0.13 20 20.7 97.28 0.01 0.08 0.01 0.13 21 26.2 98.50 0.00 0.02 22 26.2 97.97 0.01 0.08 23 27.7 97.80 0.00 0.03 0.01 0.09 24 29.4 97.68 0.00 0.04 0.01 0.10 * 25 30.1 96.47 0.00 0.05 0.01 0.01 0.13 0.01 0.17 * 26 30.3 96.43 0.00 0.00 0.00 0.06 0.01 0.01 0.13 0.01 0.18 * 27 30.5 96.25 0.00 0.01 0.00 0.07 0.01 0.01 0.14 0.01 0.19 * 28 31.2 96.22 0.00 0.01 0.00 0.07 0.01 0.01 0.14 0.01 0.19 * 29 32.2 96.02 0.00 0.02 0.00 0.08 0.01 0.01 0.15 0.01 0.20 * 30 33.4 95.95 0.00 0.02 0.01 0.08 0.01 0.01 0.16 0.01 0.20 * 31 34.3 95.90 0.00 0.02 0.01 0.09 0.01 0.01 0.16 0.01 0.20 * 32 35.5 96.10 0.00 0.02 0.00 0.08 0.01 0.01 0.15 0.01 0.19 33 36.9 96.52 0.02 0.02 0.05 0.05 0.05 0.07 0.06 34 38.5 96.81 0.01 0.01 0.02 0.02 0.02 0.03 0.03 35 39.1 96.56 0.02 0.02 0.06 0.06 0.06 0.08 0.08 36 40.7 96.48 0.02 0.02 0.05 0.05 0.05 0.07 0.06 37 42.2 96.54 0.08 0.07 0.20 0.19 0.19 0.27 0.25 38 44.2 96.36 0.03 0.03 0.25 0.24 0.57 0.56 0.53 0.75 0.71 39 46.2 96.39 0.05 0.05 0.57 0.56 1.35 1.32 1.26 1.79 1.68 40 48.3 96.34 0.12 0.11 0.95 0.92 2.18 2.13 2.03 2.87 2.70 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 70 June 2014 WSE (ft) 96.44 97.04 97.94 98.57 Disch (cfs) 1.5 15.06 59.41 105 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 48.7 96.29 0.16 0.16 1.07 1.04 2.40 2.34 2.24 3.14 2.96 42 49.2 96.24 0.20 0.19 1.12 1.09 2.45 2.39 2.29 3.19 3.00 43 49.7 96.26 0.18 0.18 1.09 1.06 2.41 2.35 2.25 3.15 2.96 44 50.2 96.09 0.29 0.29 1.29 1.25 2.65 2.58 2.47 3.40 3.20 45 50.7 96.14 0.29 0.28 1.36 1.32 2.85 2.78 2.66 3.67 3.46 46 51.2 96.13 0.30 0.29 1.37 1.33 2.85 2.78 2.66 3.67 3.45 47 51.7 96.09 0.30 0.29 1.32 1.28 2.71 2.64 2.53 3.48 3.27 48 52.2 95.89 0.40 0.39 1.49 1.45 2.89 2.82 2.70 3.65 3.43 49 52.7 95.94 0.38 0.37 1.47 1.43 2.88 2.81 2.69 3.65 3.43 50 53.2 96.08 0.36 0.35 1.56 1.52 3.20 3.12 2.99 4.10 3.86 51 53.7 95.94 0.41 0.40 1.56 1.52 3.06 2.98 2.86 3.88 3.65 52 54.2 95.94 0.38 0.37 1.46 1.42 2.86 2.79 2.67 3.62 3.41 53 54.7 95.89 0.36 0.35 1.33 1.30 2.58 2.52 2.41 3.26 3.06 54 55.2 95.88 0.35 0.34 1.28 1.24 2.47 2.41 2.30 3.12 2.93 55 55.7 95.79 0.32 0.31 1.12 1.09 2.11 2.06 1.97 2.64 2.49 56 56.2 95.57 0.34 0.34 1.11 1.07 2.00 1.95 1.87 2.47 2.32 57 56.7 95.79 0.28 0.27 0.98 0.96 1.86 1.81 1.74 2.33 2.19 58 57.2 95.69 0.31 0.30 1.03 1.00 1.91 1.86 1.78 2.38 2.24 59 57.9 95.75 0.27 0.27 0.94 0.91 1.76 1.72 1.64 2.20 2.07 60 58.2 96.34 0.05 0.05 0.44 0.42 1.00 0.97 0.93 1.32 1.24 61 59.2 96.45 0.11 0.11 0.27 0.26 0.25 0.36 0.34 * 62 60.3 97.42 0.01 0.01 0.06 0.02 0.12 * 63 60.7 97.14 0.01 0.01 0.09 0.02 0.13 * 64 61.7 96.99 0.00 0.01 0.01 0.01 0.10 0.01 0.14 65 63.2 96.89 0.16 0.16 0.79 0.77 0.74 1.14 1.07 * 66 64.2 97.19 0.01 0.01 0.08 0.02 0.13 * 67 65.2 97.34 0.01 0.01 0.07 0.02 0.12 68 66.0 97.89 0.00 0.01 0.01 0.08 Total 0 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 71 June 2014 Table A.3-43. Summary of calibration details for original and revised input decks, Grant Creek, Transect 230, main channel, high flows. WSE (ft) 97.94 98.57 99.07 Disch (cfs) 59.41 105 150.64 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 7.00 99.17 2 1.70 98.55 0.01 0.05 0.07 0.40 3 2.70 98.49 0.02 0.12 0.08 0.43 4 4.20 98.13 0.06 0.38 0.11 0.60 5 5.20 98.00 0.07 0.45 0.11 0.65 6 6.20 97.88 0.02 0.11 0.08 0.51 0.12 0.70 7 7.20 97.72 0.04 0.26 0.10 0.58 0.13 0.76 8 8.20 97.63 0.05 0.32 0.10 0.63 0.14 0.79 9 9.20 97.52 0.06 0.39 0.11 0.67 0.15 0.83 10 10.20 97.55 0.05 0.37 0.11 0.66 0.14 0.82 11 11.20 97.36 0.07 0.48 0.12 0.74 0.16 0.89 12 12.20 97.32 0.07 0.51 0.12 0.76 0.16 0.90 13 13.20 97.28 0.08 0.53 0.13 0.77 0.16 0.92 14 14.20 97.35 0.07 0.49 0.12 0.74 0.16 0.89 15 15.20 97.21 0.08 0.56 0.13 0.80 0.17 0.94 16 16.20 97.16 0.08 0.59 0.13 0.82 0.17 0.96 17 17.20 97.05 0.09 0.64 0.14 0.86 0.18 1.00 18 18.20 97.17 0.08 0.59 0.13 0.82 0.17 0.96 19 19.70 97.26 0.08 0.54 0.13 0.78 0.16 0.92 20 20.70 97.28 0.08 0.53 0.13 0.77 0.16 0.92 21 26.20 98.50 0.02 0.11 0.08 0.43 22 26.20 97.97 0.08 0.46 0.12 0.66 23 27.70 97.80 0.03 0.19 0.09 0.55 0.13 0.73 24 29.40 97.68 0.04 0.28 0.10 0.60 0.14 0.78 25 30.10 96.47 0.01 0.13 0.90 0.17 1.07 0.21 1.18 26 30.30 96.43 0.01 0.13 0.92 0.18 1.08 0.21 1.19 27 30.50 96.25 0.01 0.14 0.99 0.19 1.14 0.22 1.24 28 31.20 96.22 0.01 0.14 1.00 0.19 1.15 0.22 1.25 29 32.20 96.02 0.01 0.15 1.08 0.20 1.22 0.23 1.31 30 33.40 95.95 0.01 0.16 1.10 0.20 1.24 0.23 1.33 31 34.30 95.90 0.01 0.16 1.12 0.20 1.26 0.24 1.35 32 35.50 96.10 0.01 0.15 1.05 0.19 1.19 0.23 1.29 33 36.90 96.52 0.05 0.05 0.88 0.06 1.05 0.08 1.16 34 38.50 96.81 0.02 0.02 0.76 0.03 0.95 0.03 1.07 35 39.10 96.56 0.06 0.06 0.86 0.08 1.04 0.09 1.15 36 40.70 96.48 0.05 0.05 0.90 0.06 1.07 0.08 1.18 37 42.20 96.54 0.20 0.19 0.87 0.25 1.05 0.30 1.16 38 44.20 96.36 0.57 0.53 0.95 0.71 1.11 0.84 1.21 39 46.20 96.39 1.35 1.26 0.93 1.68 1.10 2.00 1.20 40 48.30 96.34 2.18 2.03 0.95 2.70 1.11 3.20 1.22 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 72 June 2014 WSE (ft) 97.94 98.57 99.07 Disch (cfs) 59.41 105 150.64 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 48.70 96.29 2.40 2.24 0.97 2.96 1.13 3.49 1.23 42 49.20 96.24 2.45 2.29 0.99 3.00 1.15 3.53 1.25 43 49.70 96.26 2.41 2.25 0.99 2.96 1.14 3.49 1.24 44 50.20 96.09 2.65 2.47 1.05 3.20 1.20 3.74 1.29 45 50.70 96.14 2.85 2.66 1.03 3.46 1.18 4.05 1.28 46 51.20 96.13 2.85 2.66 1.04 3.45 1.18 4.04 1.28 47 51.70 96.09 2.71 2.53 1.05 3.27 1.20 3.82 1.29 48 52.20 95.89 2.89 2.70 1.13 3.43 1.26 3.98 1.35 49 52.70 95.94 2.88 2.69 1.11 3.43 1.24 3.99 1.33 50 53.20 96.08 3.20 2.99 1.05 3.86 1.20 4.51 1.29 51 53.70 95.94 3.06 2.86 1.11 3.65 1.24 4.24 1.33 52 54.20 95.94 2.86 2.67 1.11 3.41 1.24 3.96 1.33 53 54.70 95.89 2.58 2.41 1.13 3.06 1.26 3.55 1.35 54 55.20 95.88 2.47 2.30 1.13 2.93 1.26 3.40 1.35 55 55.70 95.79 2.11 1.97 1.16 2.49 1.29 2.87 1.38 56 56.20 95.57 2.00 1.87 1.24 2.32 1.36 2.66 1.44 57 56.70 95.79 1.86 1.74 1.16 2.19 1.29 2.53 1.38 58 57.20 95.69 1.91 1.78 1.20 2.24 1.32 2.57 1.40 59 57.90 95.75 1.76 1.64 1.18 2.07 1.30 2.39 1.39 60 58.20 96.34 1.00 0.93 0.95 1.24 1.11 1.47 1.22 61 59.20 96.45 0.27 0.25 0.91 0.34 1.08 0.40 1.18 62 60.30 97.42 0.01 0.06 0.45 0.12 0.72 0.15 0.87 63 60.70 97.14 0.01 0.09 0.60 0.13 0.83 0.17 0.97 64 61.70 96.99 0.01 0.10 0.67 0.14 0.88 0.18 1.02 65 63.20 96.89 0.79 0.74 0.72 1.07 0.92 1.32 1.05 66 64.20 97.19 0.01 0.08 0.58 0.13 0.81 0.17 0.95 67 65.20 97.34 0.01 0.07 0.50 0.12 0.75 0.16 0.90 68 66.00 97.89 0.01 0.10 0.08 0.50 0.12 0.69 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 73 June 2014 Table A.3-44. Summary of calibration details for original and revised input decks, Grant Creek, Transect 400. WSE (ft) 92.95 93.64 93.915 94.49 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 97.67 2 0.0 97.29 3 1.0 97.09 4 2.0 96.68 5 3.0 96.05 6 3.7 93.97 0.03 0.33 * 7 4.2 93.70 0.01 0.05 0.33 * 8 5.2 93.28 0.01 0.02 0.06 0.34 * 9 6.5 92.93 0.00 0.02 0.03 0.07 0.34 10 7.1 93.92 0.04 0.36 11 8.0 93.87 0.00 0.03 0.04 0.38 12 9.0 93.82 0.01 0.06 0.04 0.40 * 13 10.0 93.47 0.01 0.07 0.02 0.02 0.18 0.05 0.53 14 11.0 93.12 0.17 0.17 0.33 0.30 0.31 0.73 0.74 15 12.0 93.32 0.16 0.16 0.34 0.31 0.31 0.82 0.83 16 13.0 93.52 0.21 0.20 0.64 0.59 0.59 1.80 1.81 17 14.0 93.52 0.22 0.21 0.67 0.61 0.61 1.88 1.89 18 15.0 93.57 0.15 0.14 0.59 0.54 0.54 1.75 1.76 19 16.0 93.67 0.42 0.38 0.38 1.44 1.46 20 17.0 93.67 0.21 0.19 0.19 0.72 0.73 21 18.0 93.91 0.21 * 6.20 6.35 22 19.0 93.91 0.21 * 6.20 6.35 23 20.0 93.90 0.36 * 0.12 6.28 6.43 24 21.0 93.82 1.23 1.11 1.05 6.83 7.01 25 22.0 93.77 1.01 0.92 0.89 4.48 4.56 26 23.0 93.82 0.23 0.21 0.20 1.28 1.31 27 24.0 93.82 0.21 0.19 0.18 1.17 1.20 28 25.0 93.82 1.69 1.53 1.45 9.38 9.64 * 29 26.0 93.91 0.02 0.02 0.01 0.47 0.26 30 27.1 93.52 0.53 0.51 1.64 1.50 1.50 4.60 4.64 31 28.0 93.42 0.92 0.91 2.23 2.04 2.05 5.75 5.79 32 29.0 93.52 0.90 0.86 2.76 2.53 2.53 7.75 7.80 33 30.0 93.72 2.32 2.12 2.08 8.88 8.99 34 31.5 93.52 1.14 1.10 3.52 3.22 3.23 9.88 9.95 35 32.7 93.42 1.08 1.07 2.63 2.41 2.42 6.79 6.83 36 34.0 93.27 1.31 1.31 2.71 2.48 2.50 6.40 6.45 37 35.5 93.22 1.97 1.97 3.93 3.60 3.63 9.07 9.14 38 37.0 92.97 1.98 2.00 3.57 3.27 3.31 7.57 7.63 39 38.8 92.92 0.09 0.08 1.95 1.97 3.47 3.18 3.22 7.27 7.33 40 40.5 93.22 1.67 1.67 3.33 3.05 3.08 7.69 7.74 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 74 June 2014 WSE (ft) 92.95 93.64 93.915 94.49 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 42.0 93.22 1.92 1.92 3.83 3.51 3.54 8.84 8.91 42 43.5 92.92 0.08 0.08 1.80 1.82 3.20 2.93 2.97 6.70 6.76 43 45.0 92.82 0.23 0.23 2.12 2.14 3.68 3.37 3.42 7.54 7.60 44 48.0 92.92 0.12 0.11 2.64 2.66 4.69 4.30 4.35 9.82 9.90 45 50.0 92.82 0.33 0.32 2.98 3.01 5.18 4.75 4.81 10.61 10.70 46 52.0 92.32 0.36 0.36 1.56 1.58 2.54 2.33 2.36 4.82 4.87 47 54.0 92.62 0.46 0.46 2.60 2.63 4.37 4.01 4.06 8.63 8.70 48 56.0 92.42 0.77 0.78 3.59 3.63 5.90 5.41 5.49 11.33 11.43 49 58.0 92.12 0.90 0.91 3.61 3.66 5.79 5.31 5.39 10.77 10.88 50 60.0 92.02 0.93 0.94 3.60 3.65 5.74 5.27 5.34 10.59 10.69 51 64.0 91.52 0.61 0.61 2.11 2.13 3.28 3.01 3.06 5.85 5.91 52 67.0 91.92 0.46 0.46 1.71 1.73 2.71 2.49 2.52 4.96 5.01 53 70.0 93.02 1.32 1.33 2.41 2.21 2.23 5.18 5.22 54 72.5 93.67 2.19 2.00 1.98 7.53 7.60 55 75.1 93.62 0.00 0.00 0.01 0.01 0.01 0.03 0.03 56 77.4 93.32 0.95 0.95 2.04 1.87 1.88 4.94 4.98 57 79.0 93.82 0.82 0.74 0.70 4.55 4.68 58 81.0 93.37 0.37 0.37 0.84 0.77 0.77 2.10 2.11 59 83.5 93.52 0.15 0.14 0.46 0.42 0.42 1.29 1.30 60 85.3 93.72 0.06 0.05 0.05 0.23 0.23 * 61 86.6 93.67 0.01 0.01 0.15 0.03 0.56 * 62 87.8 93.82 0.01 0.01 0.13 0.06 0.88 63 88.1 93.92 0.05 0.79 64 89.7 94.08 0.04 0.62 65 90.1 94.25 0.03 0.43 66 90.1 95.23 67 92.0 95.42 68 93.5 95.62 69 95.0 95.99 70 97.0 95.75 71 98.2 95.47 72 99.0 94.83 73 100.0 94.80 74 101.0 95.80 75 102.5 96.02 76 103.8 95.96 77 103.8 97.29 Total 3 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 75 June 2014 Table A.3-45. Summary of calibration details for original and revised input decks, Grant Creek, Transect 400, high flows. WSE (ft) 93.9 94.47 94.66 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 97.67 2 0.0 97.29 3 1.0 97.09 4 2.0 96.68 5 3.0 96.05 6 3.7 93.97 0.33 2.96 0.49 4.28 7 4.2 93.70 0.33 2.96 0.49 4.28 8 5.2 93.28 0.34 3.00 0.49 4.32 9 6.5 92.93 0.34 3.04 0.50 4.37 10 7.1 93.92 0.36 3.15 0.51 4.49 11 8.0 93.87 0.03 0.29 0.38 3.34 0.53 4.69 12 9.0 93.82 0.06 0.53 0.40 3.52 0.56 4.89 13 10.0 93.47 0.02 0.18 1.60 0.53 4.69 0.70 6.17 14 11.0 93.12 0.33 0.31 2.38 0.74 5.74 0.95 7.34 15 12.0 93.32 0.34 0.31 1.95 0.83 5.15 1.08 6.68 16 13.0 93.52 0.64 0.59 1.47 1.81 4.54 2.40 6.00 17 14.0 93.52 0.67 0.61 1.47 1.89 4.54 2.51 6.00 18 15.0 93.57 0.59 0.54 1.34 1.76 4.38 2.35 5.82 19 16.0 93.67 0.42 0.38 1.06 1.46 4.04 1.97 5.46 20 17.0 93.67 0.21 0.19 1.06 0.73 4.04 0.99 5.46 21 18.0 93.91 6.35 3.19 9.05 4.53 22 19.0 93.91 6.35 3.19 9.05 4.53 23 20.0 93.90 0.12 0.06 6.43 3.23 9.13 4.57 24 21.0 93.82 1.23 1.05 0.53 7.01 3.52 9.76 4.89 25 22.0 93.77 1.01 0.89 0.73 4.56 3.70 6.28 5.08 26 23.0 93.82 0.23 0.20 0.53 1.31 3.52 1.83 4.89 27 24.0 93.82 0.21 0.18 0.53 1.20 3.52 1.67 4.89 28 25.0 93.82 1.69 1.45 0.53 9.64 3.52 13.42 4.89 29 26.0 93.91 0.02 0.01 0.16 0.26 3.26 0.37 4.61 30 27.1 93.52 1.64 1.50 1.47 4.64 4.54 6.15 6.00 31 28.0 93.42 2.23 2.05 1.72 5.79 4.85 7.61 6.35 32 29.0 93.52 2.76 2.53 1.47 7.80 4.54 10.35 6.00 33 30.0 93.72 2.32 2.08 0.90 8.99 3.87 12.27 5.27 34 31.5 93.52 3.52 3.23 1.47 9.95 4.54 13.20 6.00 35 32.7 93.42 2.63 2.42 1.72 6.83 4.85 8.97 6.35 36 34.0 93.27 2.71 2.50 2.06 6.45 5.30 8.36 6.85 37 35.5 93.22 3.93 3.63 2.17 9.14 5.45 11.80 7.01 38 37.0 92.97 3.57 3.31 2.68 7.63 6.16 9.72 7.81 39 38.8 92.92 3.47 3.22 2.77 7.33 6.29 9.30 7.96 40 40.5 93.22 3.33 3.08 2.17 7.74 5.45 10.00 7.01 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 76 June 2014 WSE (ft) 93.9 94.47 94.66 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 42.0 93.22 3.83 3.54 2.17 8.91 5.45 11.50 7.01 42 43.5 92.92 3.20 2.97 2.77 6.76 6.29 8.58 7.96 43 45.0 92.82 3.68 3.42 2.96 7.60 6.56 9.61 8.27 44 48.0 92.92 4.69 4.35 2.77 9.90 6.29 12.57 7.96 45 50.0 92.82 5.18 4.81 2.96 10.70 6.56 13.52 8.27 46 52.0 92.32 2.54 2.36 3.81 4.87 7.83 6.05 9.71 47 54.0 92.62 4.37 4.06 3.31 8.70 7.08 10.92 8.86 48 56.0 92.42 5.90 5.49 3.65 11.43 7.59 14.26 9.43 49 58.0 92.12 5.79 5.39 4.13 10.88 8.31 13.47 10.26 50 60.0 92.02 5.74 5.34 4.28 10.69 8.55 13.22 10.53 51 64.0 91.52 3.28 3.06 5.01 5.91 9.68 7.25 11.83 52 67.0 91.92 2.71 2.52 4.43 5.01 8.78 6.18 10.80 53 70.0 93.02 2.41 2.23 2.58 5.22 6.02 6.67 7.65 54 72.5 93.67 2.19 1.98 1.06 7.60 4.04 10.29 5.46 55 75.1 93.62 0.01 0.01 1.20 0.03 4.21 0.04 5.64 56 77.4 93.32 2.04 1.88 1.95 4.98 5.15 6.48 6.68 57 79.0 93.82 0.82 0.70 0.53 4.68 3.52 6.51 4.89 58 81.0 93.37 0.84 0.77 1.84 2.11 5.00 2.76 6.52 59 83.5 93.52 0.46 0.42 1.47 1.30 4.54 1.72 6.00 60 85.3 93.72 0.06 0.05 0.90 0.23 3.87 0.32 5.27 61 86.6 93.67 0.01 0.15 1.06 0.56 4.04 0.76 5.46 62 87.8 93.82 0.01 0.13 0.53 0.88 3.52 1.22 4.89 63 88.1 93.92 0.79 3.15 1.12 4.49 64 89.7 94.08 0.62 2.51 0.95 3.81 65 90.1 94.25 0.43 1.72 0.76 3.02 66 90.1 95.23 67 92.0 95.42 68 93.5 95.62 69 95.0 95.99 70 97.0 95.75 71 98.2 95.47 72 99.0 94.83 73 100.0 94.80 74 101.0 95.80 75 102.5 96.02 76 103.8 95.96 77 103.8 97.29 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 77 June 2014 Table A.3-46. Summary of calibration details for original and revised input decks, Grant Creek, Transect 410. WSE (ft) 93.67 94.71 95.21 96.46 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 98.93 2 0.0 98.58 3 1.0 97.64 4 2.0 96.63 5 3.0 95.99 0.55 0.53 6 3.5 95.24 1.03 1.05 7 4.3 95.43 0.92 0.93 8 4.6 94.89 0.33 0.36 0.36 1.22 1.25 9 5.7 95.04 0.52 0.61 0.58 2.93 3.00 * 10 6.5 94.20 0.53 0.85 * 1.69 1.10 * 11 7.0 94.71 0.53 * 1.43 1.13 * 12 7.7 95.14 0.14 0.16 1.18 1.22 13 9.3 95.04 0.22 0.26 0.24 1.24 1.27 * 14 9.9 94.92 0.05 0.18 0.15 * 15 11.0 94.53 0.04 0.09 0.21 0.15 16 12.0 95.14 0.02 0.02 0.16 0.16 17 12.5 95.24 0.15 0.16 * 18 13.5 94.82 0.06 0.19 0.15 * 19 14.1 94.46 0.04 0.10 0.21 0.15 * 20 15.0 94.55 0.03 0.09 0.21 0.15 * 21 16.5 94.51 0.04 0.09 0.21 0.15 * 22 18.0 94.64 0.02 0.08 0.20 0.16 * 23 19.5 93.63 0.01 0.12 0.16 0.27 0.16 * 24 21.0 94.78 0.07 0.19 0.10 * 25 22.5 94.73 0.07 0.19 0.11 * 26 24.0 94.96 0.05 0.18 0.08 * 27 25.5 95.19 0.01 0.16 0.16 28 26.8 95.27 0.15 0.15 29 29.0 95.35 0.14 0.15 30 32.0 95.26 0.15 0.15 31 34.0 95.26 0.15 0.15 * 32 36.0 94.48 0.04 0.09 0.21 0.13 33 38.0 95.32 0.15 0.15 34 40.0 95.52 0.13 0.13 35 42.0 95.58 0.12 0.12 36 45.0 95.47 0.13 0.13 37 47.0 95.42 0.14 0.14 38 47.4 95.24 0.15 0.16 39 48.0 94.84 0.06 0.06 0.18 0.19 40 48.8 95.04 0.03 0.04 0.03 0.17 0.17 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 78 June 2014 WSE (ft) 93.67 94.71 95.21 96.46 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 50.0 94.84 0.07 0.08 0.08 0.24 0.24 42 52.0 94.74 0.13 0.14 0.14 0.39 0.40 43 54.5 94.84 0.39 0.43 0.42 1.33 1.36 44 55.3 94.64 0.52 0.45 2.00 2.14 2.16 5.39 5.53 45 56.6 94.34 1.54 1.54 2.63 2.78 2.83 5.84 6.01 46 57.6 94.74 4.35 4.70 4.71 12.95 13.28 47 59.0 94.34 1.94 1.94 3.30 3.49 3.56 7.33 7.54 48 60.0 93.64 0.13 0.13 1.92 1.96 2.41 2.52 2.59 4.32 4.46 49 62.0 94.04 1.72 1.74 2.41 2.53 2.59 4.77 4.91 50 63.5 93.94 2.58 2.62 3.49 3.66 3.75 6.70 6.91 51 64.5 94.04 0.35 0.35 0.49 0.51 0.53 0.97 1.00 52 66.0 94.04 2.07 2.10 2.91 3.06 3.13 5.76 5.93 53 66.7 93.94 1.59 1.61 2.15 2.25 2.31 4.13 4.26 54 69.0 93.74 1.96 1.99 2.51 2.63 2.70 4.59 4.74 55 71.0 94.24 2.32 2.33 3.63 3.83 3.91 7.71 7.94 56 72.5 94.14 3.67 3.71 5.40 5.68 5.81 11.04 11.37 57 74.0 94.24 4.18 4.21 6.54 6.89 7.04 13.89 14.30 58 77.0 93.44 0.73 0.73 2.92 2.97 3.54 3.69 3.80 6.12 6.32 59 79.0 93.34 0.93 0.93 3.04 3.10 3.64 3.80 3.91 6.19 6.40 60 81.5 93.24 1.18 1.18 3.39 3.46 4.01 4.18 4.31 6.72 6.95 61 83.5 95.24 4.28 4.36 62 85.0 93.14 1.65 1.66 4.32 4.41 5.06 5.27 5.43 8.37 8.66 63 86.0 93.04 0.61 0.62 1.49 1.52 1.73 1.80 1.86 2.83 2.93 64 89.0 92.94 0.97 0.97 2.21 2.25 2.54 2.64 2.73 4.11 4.25 65 91.0 92.84 1.49 1.49 3.23 3.30 3.69 3.84 3.96 5.90 6.11 66 94.6 92.74 0.87 0.87 1.81 1.85 2.05 2.13 2.20 3.25 3.36 67 95.0 92.74 0.96 0.97 2.01 2.05 2.28 2.37 2.45 3.61 3.74 68 96.4 94.64 0.07 0.06 0.27 0.29 0.29 0.73 0.75 69 97.9 94.69 0.01 0.00 0.10 0.11 0.11 0.28 0.29 * 70 99.3 94.88 0.08 0.26 0.22 71 99.5 95.40 0.20 0.20 72 99.5 96.15 0.09 0.08 73 101.0 95.90 0.13 0.13 74 102.5 96.41 0.03 0.01 75 105.2 96.04 0.11 0.10 76 107.7 96.15 0.09 0.08 77 110.0 96.33 0.05 0.04 78 111.9 96.06 0.10 0.10 79 112.1 95.61 0.17 0.17 80 113.6 95.45 0.19 0.20 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 79 June 2014 WSE (ft) 93.67 94.71 95.21 96.46 Disch (cfs) 10 100 200 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev * 81 115.2 95.20 0.01 0.22 0.22 * 82 116.5 94.77 0.10 0.27 0.22 * 83 117.8 94.64 0.03 0.11 0.29 0.21 * 84 119.0 94.69 0.01 0.11 0.28 0.20 85 119.2 95.49 0.19 0.19 86 122.5 95.85 0.14 0.14 87 126.0 96.06 0.10 0.10 88 129.0 96.60 89 133.0 96.94 90 135.0 97.70 91 136.2 97.71 92 136.2 98.74 Total 2 * * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 80 June 2014 Table A.3-47. Summary of calibration details for original and revised input decks, Grant Creek, Transect 410, high flows. WSE (ft) 95.19 96.42 96.87 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 98.93 2 0.0 98.58 3 1.0 97.64 4 2.0 96.63 0.39 0.87 5 3.0 95.99 0.53 1.29 0.93 2.08 6 3.5 95.24 1.05 2.54 1.41 3.15 7 4.3 95.43 0.93 2.26 1.30 2.90 8 4.6 94.89 0.33 0.36 1.02 1.25 3.03 1.60 3.59 9 5.7 95.04 0.52 0.58 0.64 3.00 2.82 3.90 3.40 10 6.5 94.20 1.10 2.45 1.49 3.07 11 7.0 94.71 1.13 2.53 1.52 3.14 12 7.7 95.14 0.16 0.42 1.22 2.73 1.61 3.31 13 9.3 95.04 0.22 0.24 0.64 1.27 2.82 1.65 3.40 14 9.9 94.92 0.15 2.53 0.21 3.14 15 11.0 94.53 0.15 2.51 0.21 3.12 16 12.0 95.14 0.02 0.30 0.16 2.68 0.22 3.28 17 12.5 95.24 0.16 2.54 0.21 3.15 18 13.5 94.82 0.15 2.45 0.20 3.07 19 14.1 94.46 0.15 2.45 0.20 3.07 20 15.0 94.55 0.15 2.48 0.20 3.10 21 16.5 94.51 0.15 2.53 0.21 3.14 22 18.0 94.64 0.16 2.56 0.21 3.16 23 19.5 93.63 0.16 2.54 0.21 3.15 24 21.0 94.78 0.10 1.68 0.16 2.40 25 22.5 94.73 0.11 1.77 0.16 2.48 26 24.0 94.96 0.08 1.35 0.14 2.13 27 25.5 95.19 0.16 2.54 0.21 3.15 28 26.8 95.27 0.15 2.50 0.21 3.11 29 29.0 95.35 0.15 2.38 0.20 3.00 30 32.0 95.26 0.15 2.51 0.21 3.12 31 34.0 95.26 0.15 2.51 0.21 3.12 32 36.0 94.48 0.13 2.18 0.19 2.83 33 38.0 95.32 0.15 2.42 0.20 3.04 34 40.0 95.52 0.13 2.12 0.18 2.77 35 42.0 95.58 0.12 2.02 0.18 2.69 36 45.0 95.47 0.13 2.20 0.19 2.84 37 47.0 95.42 0.14 2.27 0.19 2.91 38 47.4 95.24 0.16 2.54 0.21 3.15 39 48.0 94.84 0.06 1.13 0.19 3.09 0.24 3.65 40 48.8 95.04 0.03 0.03 0.64 0.17 2.82 0.23 3.40 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 81 June 2014 WSE (ft) 95.19 96.42 96.87 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 50.0 94.84 0.07 0.08 1.13 0.24 3.09 0.31 3.65 42 52.0 94.74 0.13 0.14 1.34 0.40 3.22 0.50 3.77 43 54.5 94.84 0.39 0.42 1.13 1.36 3.09 1.73 3.65 44 55.3 94.64 2.00 2.16 1.54 5.53 3.35 6.94 3.88 45 56.6 94.34 2.63 2.83 2.06 6.01 3.72 7.39 4.23 46 57.6 94.74 4.35 4.72 1.34 13.28 3.22 16.79 3.77 47 59.0 94.34 3.30 3.56 2.06 7.54 3.72 9.27 4.23 48 60.0 93.64 2.41 2.59 3.08 4.46 4.52 5.31 4.98 49 62.0 94.04 2.41 2.59 2.52 4.91 4.07 5.95 4.56 50 63.5 93.94 3.49 3.75 2.66 6.91 4.18 8.33 4.67 51 64.5 94.04 0.49 0.53 2.52 1.00 4.07 1.21 4.56 52 66.0 94.04 2.91 3.13 2.52 5.93 4.07 7.18 4.56 53 66.7 93.94 2.15 2.31 2.66 4.26 4.18 5.13 4.67 54 69.0 93.74 2.51 2.70 2.94 4.74 4.41 5.67 4.88 55 71.0 94.24 3.63 3.91 2.22 7.94 3.84 9.70 4.34 56 72.5 94.14 5.40 5.81 2.37 11.37 3.95 13.83 4.45 57 74.0 94.24 6.54 7.04 2.22 14.30 3.84 17.48 4.34 58 77.0 93.44 3.54 3.80 3.34 6.32 4.73 7.49 5.19 59 79.0 93.34 3.64 3.91 3.47 6.40 4.84 7.56 5.29 60 81.5 93.24 4.01 4.31 3.59 6.95 4.94 8.19 5.39 61 83.5 95.24 4.36 2.54 5.84 3.15 62 85.0 93.14 5.06 5.43 3.71 8.66 5.05 10.17 5.48 63 86.0 93.04 1.73 1.86 3.83 2.93 5.15 3.43 5.58 64 89.0 92.94 2.54 2.73 3.95 4.25 5.25 4.97 5.68 65 91.0 92.84 3.69 3.96 4.07 6.11 5.35 7.13 5.78 66 94.6 92.74 2.05 2.20 4.18 3.36 5.45 3.91 5.87 67 95.0 92.74 2.28 2.45 4.18 3.74 5.45 4.35 5.87 68 96.4 94.64 0.27 0.29 1.54 0.75 3.35 0.94 3.88 69 97.9 94.69 0.10 0.11 1.44 0.29 3.29 0.36 3.83 70 99.3 94.88 0.22 2.53 0.30 3.14 71 99.5 95.40 0.20 2.30 0.28 2.94 72 99.5 96.15 0.08 0.94 0.17 1.82 73 101.0 95.90 0.13 1.46 0.21 2.22 74 102.5 96.41 0.01 0.08 0.13 1.35 75 105.2 96.04 0.10 1.18 0.19 2.00 76 107.7 96.15 0.08 0.94 0.17 1.82 77 110.0 96.33 0.04 0.44 0.14 1.50 78 111.9 96.06 0.10 1.14 0.19 1.97 79 112.1 95.61 0.17 1.97 0.25 2.65 80 113.6 95.45 0.20 2.23 0.27 2.87 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 82 June 2014 WSE (ft) 95.19 96.42 96.87 Disch (cfs) 200 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 81 115.2 95.20 0.22 2.53 0.30 3.14 82 116.5 94.77 0.22 2.45 0.29 3.07 83 117.8 94.64 0.21 2.38 0.29 3.00 84 119.0 94.69 0.20 2.30 0.28 2.94 85 119.2 95.49 0.19 2.17 0.27 2.82 86 122.5 95.85 0.14 1.56 0.22 2.30 87 126.0 96.06 0.10 1.14 0.19 1.97 88 129.0 96.60 0.09 0.94 89 133.0 96.94 90 135.0 97.70 91 136.2 97.71 92 136.2 98.74 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 83 June 2014 Table A.3-48. Summary of calibration details for original and revised input decks, Grant Creek, Transect 430. WSE (ft) 88.76 89.39 89.72 90.99 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 1 0.0 94.46 2 0.1 94.08 3 1.7 92.43 4 4.9 91.95 5 5.6 90.32 0.49 0.49 6 7.5 90.22 0.54 0.54 7 9.0 90.30 0.50 0.50 8 9.1 90.63 0.32 0.32 9 9.4 90.31 0.50 0.50 10 11.9 90.09 0.60 0.60 11 13.0 89.60 0.11 0.11 0.81 0.80 12 13.2 89.50 0.17 0.17 0.84 0.84 13 13.8 90.14 0.58 0.58 14 14.6 89.60 0.11 0.11 0.81 0.80 15 16.0 89.50 0.16 0.17 0.17 0.84 0.84 16 17.0 89.50 0.03 0.03 0.03 0.16 0.16 17 18.0 89.40 0.03 0.03 0.03 0.13 0.13 18 18.7 89.45 0.47 0.50 0.50 2.18 2.17 19 19.0 90.00 0.02 0.02 20 19.4 89.20 0.00 0.00 0.01 0.01 0.01 0.03 0.03 21 20.5 89.00 0.12 0.12 0.21 0.22 0.22 0.58 0.58 22 22.0 88.50 0.12 0.12 1.06 1.06 1.58 1.64 1.64 3.54 3.52 23 24.4 88.10 0.19 0.19 1.17 1.17 1.65 1.71 1.71 3.37 3.35 24 26.0 87.90 0.13 0.13 0.71 0.71 0.98 1.01 1.01 1.93 1.92 25 27.0 87.80 0.31 0.31 1.68 1.68 2.30 2.37 2.38 4.47 4.45 26 28.0 87.80 0.39 0.39 2.15 2.15 2.94 3.04 3.04 5.72 5.68 27 29.4 87.70 0.48 0.48 2.59 2.59 3.52 3.63 3.64 6.75 6.71 28 31.0 87.70 0.50 0.50 2.65 2.65 3.61 3.73 3.73 6.92 6.88 29 31.9 87.40 0.37 0.37 1.88 1.88 2.52 2.60 2.60 4.67 4.64 30 33.0 87.30 0.48 0.48 2.37 2.37 3.16 3.26 3.26 5.79 5.76 31 35.2 87.30 0.56 0.56 2.77 2.77 3.69 3.80 3.81 6.77 6.72 32 36.5 87.40 0.54 0.54 2.72 2.72 3.64 3.75 3.76 6.74 6.70 33 38.0 87.50 0.51 0.51 2.60 2.60 3.50 3.61 3.61 6.55 6.51 34 39.8 87.90 0.43 0.43 2.41 2.41 3.33 3.44 3.44 6.57 6.53 35 42.0 88.20 0.40 0.40 2.61 2.61 3.70 3.83 3.83 7.71 7.66 36 44.7 88.60 0.19 0.19 2.15 2.15 3.27 3.39 3.39 7.56 7.51 37 46.7 88.40 0.33 0.33 2.57 2.57 3.76 3.89 3.90 8.20 8.15 38 47.5 88.30 0.29 0.29 1.99 1.99 2.86 2.96 2.96 6.09 6.05 39 49.2 88.20 0.18 0.18 1.19 1.19 1.69 1.75 1.75 3.52 3.50 40 51.0 88.30 0.29 0.29 2.04 2.04 2.94 3.04 3.04 6.26 6.22 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 84 June 2014 WSE (ft) 88.76 89.39 89.72 90.99 Disch (cfs) 10 100 182 700 Rv Pt Sta Elev Orig Rev Orig Rev Meas Orig * Rev * Orig Rev 41 52.8 88.30 0.18 0.18 1.24 1.24 1.79 1.85 1.85 3.81 3.79 42 54.2 88.50 0.16 0.16 1.41 1.41 2.09 2.16 2.17 4.68 4.66 43 56.0 88.50 0.11 0.11 1.02 1.02 1.52 1.57 1.58 3.41 3.39 44 57.0 88.90 0.90 0.90 1.52 1.58 1.58 3.97 3.95 45 58.0 89.45 0.94 1.01 1.01 4.37 4.34 * 46 60.9 89.60 0.58 * 4.08 3.75 47 62.0 89.45 0.75 0.80 0.80 3.48 3.46 48 63.0 89.45 0.95 1.02 1.02 4.41 4.39 49 65.5 89.05 0.97 0.97 1.84 1.92 1.92 5.26 5.23 50 67.2 89.40 0.70 0.74 0.75 2.94 2.92 51 68.3 89.45 0.79 0.85 0.85 3.67 3.65 52 70.5 89.30 0.13 0.13 0.43 0.45 0.45 1.55 1.54 53 71.5 89.50 -0.03 -0.03 - 0.03 -0.16 - 0.16 54 72.2 89.40 0.18 0.19 0.19 0.76 0.75 55 73.3 89.30 0.07 0.07 0.24 0.25 0.25 0.87 0.86 56 75.2 89.50 0.23 0.25 0.25 1.21 1.21 * 57 80.7 89.40 -0.06 -0.06 0.21 -0.25 0.82 * 58 81.5 89.68 -0.02 -0.22 0.69 59 83.3 90.90 -0.04 0.12 60 85.4 91.00 61 88.3 92.16 62 90.0 93.43 63 90.2 93.64 64 92.0 95.14 65 93.7 97.29 66 96.1 98.09 67 96.1 98.35 Total 1 * 0 * Note: An * means the modeled velocity exceeds the measured velocity by 0.2 ft/sec or 20%. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 85 June 2014 Table A.3-49. Summary of calibration details for original and revised input decks, Grant Creek, Transect 430, high flows. WSE (ft) 89.72 90.99 91.51 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 1 0.0 94.46 2 0.1 94.08 3 1.7 92.43 4 4.9 91.95 5 5.6 90.32 0.49 1.80 0.76 2.70 6 7.5 90.22 0.54 1.98 0.80 2.85 7 9.0 90.30 0.50 1.84 0.77 2.73 8 9.1 90.63 0.32 1.19 0.62 2.21 9 9.4 90.31 0.50 1.82 0.76 2.72 10 11.9 90.09 0.60 2.20 0.85 3.04 11 13.0 89.60 0.11 0.46 0.80 2.94 1.04 3.71 12 13.2 89.50 0.17 0.70 0.84 3.08 1.08 3.84 13 13.8 90.14 0.58 2.12 0.83 2.97 14 14.6 89.60 0.11 0.46 0.80 2.94 1.04 3.71 15 16.0 89.50 0.16 0.17 0.70 0.84 3.08 1.08 3.84 16 17.0 89.50 0.03 0.03 0.70 0.16 3.08 0.20 3.84 17 18.0 89.40 0.03 0.03 0.90 0.13 3.22 0.16 3.97 18 18.7 89.45 0.47 0.50 0.81 2.17 3.15 2.77 3.90 19 19.0 90.00 0.02 2.34 0.03 3.17 20 19.4 89.20 0.01 0.01 1.25 0.03 3.49 0.04 4.22 21 20.5 89.00 0.21 0.22 1.56 0.58 3.75 0.71 4.46 22 22.0 88.50 1.58 1.64 2.23 3.52 4.35 4.20 5.03 23 24.4 88.10 1.65 1.71 2.69 3.35 4.81 3.93 5.47 24 26.0 87.90 0.98 1.01 2.91 1.92 5.03 2.24 5.69 25 27.0 87.80 2.30 2.38 3.02 4.45 5.14 5.17 5.79 26 28.0 87.80 2.94 3.04 3.02 5.68 5.14 6.61 5.79 27 29.4 87.70 3.52 3.64 3.12 6.71 5.25 7.78 5.90 28 31.0 87.70 3.61 3.73 3.12 6.88 5.25 7.98 5.90 29 31.9 87.40 2.52 2.60 3.43 4.64 5.56 5.34 6.20 30 33.0 87.30 3.16 3.26 3.53 5.76 5.67 6.61 6.30 31 35.2 87.30 3.69 3.81 3.53 6.72 5.67 7.72 6.30 32 36.5 87.40 3.64 3.76 3.43 6.70 5.56 7.71 6.20 33 38.0 87.50 3.50 3.61 3.33 6.51 5.46 7.51 6.10 34 39.8 87.90 3.33 3.44 2.91 6.53 5.03 7.62 5.69 35 42.0 88.20 3.70 3.83 2.58 7.66 4.70 9.02 5.37 36 44.7 88.60 3.27 3.39 2.10 7.51 4.23 9.00 4.92 37 46.7 88.40 3.76 3.90 2.35 8.15 4.47 9.68 5.15 38 47.5 88.30 2.86 2.96 2.47 6.05 4.58 7.16 5.26 39 49.2 88.20 1.69 1.75 2.58 3.50 4.70 4.12 5.37 40 51.0 88.30 2.94 3.04 2.47 6.22 4.58 7.36 5.26 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 86 June 2014 WSE (ft) 89.72 90.99 91.51 Disch (cfs) 182 700 1000 Rv Pt Sta Elev Meas 1 Vel Depth 1 Vel Depth 1 Vel Depth 41 52.8 88.30 1.79 1.85 2.47 3.79 4.58 4.48 5.26 42 54.2 88.50 2.09 2.17 2.23 4.66 4.35 5.55 5.03 43 56.0 88.50 1.52 1.58 2.23 3.39 4.35 4.04 5.03 44 57.0 88.90 1.52 1.58 1.70 3.95 3.87 4.82 4.58 45 58.0 89.45 0.94 1.01 0.81 4.34 3.15 5.54 3.90 46 60.9 89.60 3.75 2.73 4.98 3.51 47 62.0 89.45 0.75 0.80 0.81 3.46 3.15 4.42 3.90 48 63.0 89.45 0.95 1.02 0.81 4.39 3.15 5.60 3.90 49 65.5 89.05 1.84 1.92 1.49 5.23 3.68 6.44 4.40 50 67.2 89.40 0.70 0.75 0.90 2.92 3.22 3.71 3.97 51 68.3 89.45 0.79 0.85 0.81 3.65 3.15 4.66 3.90 52 70.5 89.30 0.43 0.45 1.09 1.54 3.36 1.94 4.09 53 71.5 89.50 -0.03 -0.03 0.70 -0.16 3.08 -0.20 3.84 54 72.2 89.40 0.18 0.19 0.90 0.75 3.22 0.95 3.97 55 73.3 89.30 0.24 0.25 1.09 0.86 3.36 1.08 4.09 56 75.2 89.50 0.23 0.25 0.70 1.21 3.08 1.55 3.84 57 80.7 89.40 -0.06 0.21 0.90 0.82 3.22 1.04 3.97 58 81.5 89.68 0.69 2.73 0.92 3.51 59 83.3 90.90 0.12 0.46 0.45 1.72 60 85.4 91.00 0.40 1.53 61 88.3 92.16 62 90.0 93.43 63 90.2 93.64 64 92.0 95.14 65 93.7 97.29 66 96.1 98.09 67 96.1 98.35 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 87 June 2014 Table A.3-50. Summary of calibration details, Grant Creek. Trans No. 100 110 120 130 140 150 160 200 DISCHARGE Meas./ 0.01 0.0 17.0 17.0 17.0 17.0 17.0 1.5 Given 0.25 0.3 131.6 63.6 131.6 131.6 63.6 5.7 4.31 4.3 182 131.6 182.0 200.0 200.0 11.8 5.90 5.9 694 182 770 693 693 14.8 8.7 694 63.1 Calc. 0.01 0.0 17 17 17 17 17 1.5 1.01 0.3 123 60 136 133 68 5.7 1.09 3.8 192.5 131.6 176.2 198.0 179.8 11.3 0.92 6.1 693.54 158.41 695 693 724 17.2 9.0 676 55.1 Stage (given) 95.82 98.1 95.63 95.67 97.33 94.31 94.40 92.0 96.02 98.3 96.58 96.24 98.00 95.00 94.93 93.0 96.69 98.9 96.86 96.79 98.14 95.22 95.43 93.7 96.92 99.2 97.83 97.14 99.26 96.23 96.47 94.2 99.4 98.68 96.1 Plotting Stage (given) 0.06 0.03 1.77 0.87 0.39 0.47 0.86 1.82 0.26 0.19 2.72 1.44 1.06 1.16 1.39 2.81 0.93 0.82 3.00 1.99 1.20 1.38 1.89 3.50 1.16 1.06 3.97 2.34 2.32 2.39 2.93 4.00 3.88 5.89 Ratio of Modeled vs Predicted Discharge (given) based on Stage-Discharge Relationship 0.9876 1.0307 0.9875 1.0263 1.0024 1.0020 0.9998 1.0368 1.0125 0.9180 1.0707 0.9812 0.9675 0.9879 0.9396 0.9955 1.0873 1.1287 0.9456 1.0002 1.0332 1.0100 1.1124 1.0376 9198 0.972 1.0002 0.9297 0.9979 1.0002 0.9569 0.8603 0.9633 1.0263 1.0854 Mean Error of Stage/Discharge Relationship 4.8107 6.0003 3.4120 3.6822 1.7553 0.6098 5.2644 6.3472 Stage/Discharge Relationship (S vs Q) S=A*Q**B+SZF A= 4.643 5.464 1.264 24.384 120.526 94.997 23.779 0.222 B= 2.178 1.806 4.575 2.454 2.082 2.281 3.178 3.141 SZF= 95.760 98.110 93.860 94.800 96.940 93.840 93.540 90.180 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 88 June 2014 Table A.3-51. Summary of calibration details, Grant Creek. Trans No. 210 220 230-MC 230-SC 300 310 210 320 DISCHARGE Meas./ 133 17.0 17.0 133 0.29 63.6 133 1.36 Given 440 63.6 63.6 440 1.08 131.6 440 12.43 705.0 182.0 182.0 705.0 2.2 165.6 705.0 20.98 706 706 3.07 113.84 9.82 Calc. 133.019 17 17 133.014 0.29 63 133.019 1.36 439.778 62 62 439.84 1.054 134 439.778 12.10 705.256 190.6 190.5 705.184 2.341 163.2 705.256 21.78 691.868 691.424 3.041 112.68 9.716 Stage (given) 94.515 94.71 94.83 94.515 94 95.85 94.515 95.82 95.42 95.06 95.27 95.42 94.59 96.29 95.42 96.09 96.09 95.55 95.85 96.09 95.12 96.42 96.09 96.22 96.45 96.83 95.33 96.82 96.545 Plotting Stage (given) 0.58 0.52 0.84 0.57 0.99 2.03 0.58 0.17 1.48 0.88 1.28 1.48 1.58 2.47 1.48 0.45 2.15 1.36 1.86 2.15 2.11 2.60 2.15 0.58 2.27 2.84 2.32 1.18 3.54 Ratio of Modeled vs Predicted Discharge (given) based on Stage- Discharge Relationship 0.9999 0.9550 0.9991 0.9999 0.9991 1.0039 0.9999 1.0005 1.0005 1.0285 1.0262 1.0004 1.0248 0.9815 1.0005 1.0270 0.9996 0.9977 0.9552 0.9997 0.9571 1.0149 0.9996 0.9634 1.0204 1.0211 1.0096 1.0103 1.0107 Mean Error of Stage/Discharge Relationship 0.0337 2.4282 2.3468 0.0242 1.8023 1.2495 0.0337 1.8738 Stage/Discharge Relationship (S vs Q) S=A*Q**B+SZF A= 267.874 85.619 29.381 268.342 0.298 4.232 267.874 76.852 B= 1.265 2.542 3.026 1.263 2.758 3.822 1.265 2.314 SZF= 93.940 94.180 93.990 93.941 93.010 93.820 93.940 95.640 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 89 June 2014 Table A.3-52. Summary of calibration details, Grant Creek. Trans No. 320 330-MC 330-2nd 330-3rd 400 410 430 DISCHARGE Meas./ 1.36 1.36 0.47 0.06 17.0 17.0 17.0 Given 12.43 15.87 1.27 0.1 57.6 57.6 131.6 20.98 59.4 5.7 1.6 131.6 200.0 182.0 113.84 113.84 10.74 200 706 706 706 Calc. 1.36 1.359 0.47 0.059 17 17 17 12.10 15.896 1.287 0.103 58 60 135 21.78 59.462 5.492 1.593 132.1 197.9 177.3 112.68 113.651 11.023 205.75 699.07 706.36 688.489 Stage (given) 95.82 96.43 95.85 95.85 93.08 93.83 88.85 96.09 97.06 96.05 95.86 93.45 94.40 89.54 96.22 97.945 96.48 96.445 93.74 95.19 89.70 96.82 98.67 96.77 93.915 96.42 91 94.465 Plotting Stage (given) 0.17 0.23 0.52 0.01 1.56 1.09 0.34 0.45 0.86 0.72 0.02 1.93 1.66 1.04 0.58 1.74 1.15 0.60 2.22 2.45 1.20 1.18 2.47 1.44 2.40 3.68 2.50 2.95 Ratio of Modeled vs Predicted Discharge (given) based on Stage-Discharge Relationship 1.0005 1.0009 1.0006 1.0231 1.0190 1.0289 1.0030 1.0270 0.9984 0.9865 0.9729 0.9878 0.9521 0.9719 0.9634 0.9991 1.0397 1.0047 0.9967 1.0107 1.0263 1.0103 1.0017 0.9743 0.9721 1.01 0.9996 1.0254 Mean Error of Stage/Discharge Relationship 1.8738 0.1261 1.9699 1.8365 1.7569 2.4706 1.4519 Stage/Discharge Relationship (S vs Q) S=A*Q**B+SZF A= 76.852 21.064 3.563 2.388 1.251 12.669 125.861 B= 2.314 1.864 3.098 0.802 5.843 3.081 1.883 SZF= 95.640 96.200 95.330 95.840 91.520 92.740 88.500 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 3 Page 90 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4: Cross Sections, WSE and Flow Hydraulics Appendix 4a. Reach 1 Main Channel Appendix 4b. Reach 1 Side Channel Appendix 4c. Reach 2 Appendix 4d. Reach 3 Main Channel Appendix 4e. Reach 3 Side Channel Appendix 4f Reach 4 FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4a Reach 1 Main Channel This sub-appendix contains the following figures: Figure A.4a-1. Transect T120 bed profile and Water Surface Elevation (WSE), 10–1,000 cfs. Figure A.4a-2. Transect T130 bed profile and WSE, 10–1,000 cfs. Figure A.4a-3. Transect T140 bed profile and WSE, 10-1,000 cfs. Figure A.4a-4. Transect T150 bed profile and WSE, 10-1,000 cfs. Figure A.4a-5. Transect T160 bed profile and WSE, 10-1,000 cfs. Figure A.4a-6. Reach 1 main channel wetted perimeter vs flow. Figure A.4a-7. Reach 1 main channel wetted width vs flow. Figure A.4a-8. Reach 1 main channel hydraulic radius vs flow. Figure A.4a-9. Reach 1 main channel average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4a Page 1 June 2014 Figure A.4a-1. Transect T120 bed profile and Water Surface Elevation (WSE), 10–1,000 cfs. Figure A.4a-2. Transect T130 bed profile and WSE, 10–1,000 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4a Page 2 June 2014 Figure A.4a-3. Transect T140 bed profile and WSE, 10-1,000 cfs. Figure A.4a-4. Transect T150 bed profile and WSE, 10-1,000 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4a Page 3 June 2014 Figure A.4a-5. Transect T160 bed profile and WSE, 10-1,000 cfs. Figure A.4a-6. Reach 1 main channel wetted perimeter vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4a Page 4 June 2014 Figure A.4a-7. Reach 1 main channel wetted width vs flow. Figure A.4a-8. Reach 1 main channel hydraulic radius vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4a Page 5 June 2014 Figure A.4a-9. Reach 1 main channel average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4a Page 6 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4b Reach 1 Side Channel This sub-appendix contains the following figures: Figure A.4b-1. Transect T100 bed profile and WSE, 0.1-20 cfs. Figure A.4b-2. Transect T110 bed profile and WSE, 0.1-20 cfs. Figure A.4b-3. Reach 1 side channel wetted perimeter vs flow. Figure A.4b-4. Reach 1 side channel wetted width vs flow. Figure A.4b-5. Reach 1 side channel hydraulic radius vs flow. Figure A.4b-6. Reach 1 side channel average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4b Page 1 June 2014 Figure A.4b-1. Transect T100 bed profile and WSE, 0.1-20 cfs. Figure A.4b-2. Transect T110 bed profile and WSE, 0.1-20 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4b Page 2 June 2014 Figure A.4b-3. Reach 1 side channel wetted perimeter vs flow. Figure A.4b-4. Reach 1 side channel wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4b Page 3 June 2014 Figure A.4b-5. Reach 1 side channel hydraulic radius vs flow. Figure A.4b-6. Reach 1 side channel average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4b Page 4 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4c Reach 2 This sub-appendix contains the following figures: Figure A.4c-1. Transect T200 bed profile and WSE, 0.89–89 cfs. Figure A.4c-2. Transect T210 bed profile and WSE, 10-1,000 cfs. Figure A.4c-3. T200 side lobe wetted perimeter vs flow. Figure A.4c-4. T200 side lobe wetted width vs flow. Figure A.4c-5. T200 side lobe hydraulic radius vs flow. Figure A.4c-6. T200 side lobe average depth vs flow. Figure A.4c-7. Reach 2 wetted perimeter vs flow. Figure A.4c-8. Reach 2 wetted width vs flow. Figure A.4c-9. Reach 2 hydraulic radius vs flow. Figure A.4c-10. Reach 2 average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4c Page 1 June 2014 Figure A.4c-1. Transect T200 bed profile and WSE, 0.89–89 cfs. Figure A.4c-2. Transect T210 bed profile and WSE, 10-1,000 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4c Page 2 June 2014 Figure A.4c-3. T200 side lobe wetted perimeter vs flow. Figure A.4c-4. T200 side lobe wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4c Page 3 June 2014 Figure A.4c-5. T200 side lobe hydraulic radius vs flow. Figure A.4c-6. T200 side lobe average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4c Page 4 June 2014 Figure A.4c-7. Reach 2 wetted perimeter vs flow. Figure A.4c-8. Reach 2 wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4c Page 5 June 2014 Figure A.4c-9. Reach 2 hydraulic radius vs flow. Figure A.4c-10. Reach 2 average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4c Page 6 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4d Reach 3 Main Channel This sub-appendix contains the following figures: Figure A.4d-1. Transect T300 bed profile and WSE, 0.17–17 cfs. Figure A.4d-2. Transect T310 bed profile and WSE, 10–1,000 cfs. Figure A.4d-3. T300 side lobe wetted perimeter vs flow. Figure A.4d-4. T300 side lobe wetted width vs flow. Figure A.4d-5. T300 side lobe hydraulic radius vs flow. Figure A.4d-6. T300 side lobe average depth vs flow. Figure A.4d-7. Reach 3 main channel wetted perimeter vs flow. Figure A.4d-8. Reach 3 main channel wetted width vs flow. Figure A.4d-9. Reach 3 main channel hydraulic radius vs flow. Figure A.4d-10. Reach 3 main channel average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4d Page 1 June 2014 Figure A.4d-1. Transect T300 bed profile and WSE, 0.17–17 cfs. Figure A.4d-2. Transect T310 bed profile and WSE, 10–1,000 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4d Page 2 June 2014 Figure A.4d-3. T300 side lobe wetted perimeter vs flow. Figure A.4d-4. T300 side lobe wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4d Page 3 June 2014 Figure A.4d-5. T300 side lobe hydraulic radius vs flow. Figure A.4d-6. T300 side lobe average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4d Page 4 June 2014 Figure A.4d-7. Reach 3 main channel wetted perimeter vs flow. Figure A.4d-8. Reach 3 main channel wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4d Page 5 June 2014 Figure A.4d-9. Reach 3 main channel hydraulic radius vs flow. Figure A.4d-10. Reach 3 main channel average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4d Page 6 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4e Reach 3 Side Channel This sub-appendix contains the following figures: Figure A.4e-1. Transect T320 bed profile and WSE, 1.6–158 cfs. Figure A.4e-2. Transect T330 primary bed profile and WSE, 1.5–151 cfs. Figure A.4e-3. Transect T330 secondary bed profile and WSE, 0.13–12.7 cfs. Figure A.4e-4. Transect T330 tertiary bed profile and WSE, 0.13–97 cfs. Figure A.4e-5. Transect T320 wetted perimeter vs flow. Figure A.4e-6. Transect T320 wetted width vs flow. Figure A.4e-7. Transect T320 hydraulic radius vs flow. Figure A.4e-8. Transect T320 average depth vs flow. Figure A.4e-9. Transect T330 primary wetted perimeter vs flow. Figure A.4e-10. Transect T330 primary wetted width vs flow. Figure A.4e-11. Transect T330 primary hydraulic radius vs flow. Figure A.4e-12. Transect T330 primary average depth vs flow. Figure A.4e-13. Transect T330 secondary wetted perimeter vs flow. Figure A.4e-14. Transect T330 secondary wetted width vs flow. Figure A.4e-15. Transect T330 secondary hydraulic radius vs flow. Figure A.4e-16. Transect T330 secondary average depth vs flow. Figure A.4e-17. Transect T330 Tertiary wetted perimeter vs flow. Figure A.4e-18. Transect T330 tertiary wetted width vs flow. Figure A.4e-19. Transect T330 tertiary hydraulic radius vs flow. Figure A.4e-20. Transect T330 tertiary average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 1 June 2014 Figure A.4e-1. Transect T320 bed profile and WSE, 1.6–158 cfs. Figure A.4e-2. Transect T330 primary bed profile and WSE, 1.5–151 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 2 June 2014 Figure A.4e-3. Transect T330 secondary bed profile and WSE, 0.13–12.7 cfs. Figure A.4e-4. Transect T330 tertiary bed profile and WSE, 0.13–97 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 3 June 2014 Figure A.4e-5. Transect T320 wetted perimeter vs flow. Figure A.4e-6. Transect T320 wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 4 June 2014 Figure A.4e-7. Transect T320 hydraulic radius vs flow. Figure A.4e-8. Transect T320 average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 5 June 2014 Figure A.4e-9. Transect T330 primary wetted perimeter vs flow. Figure A.4e-10. Transect T330 primary wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 6 June 2014 Figure A.4e-11. Transect T330 primary hydraulic radius vs flow. Figure A.4e-12. Transect T330 primary average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 7 June 2014 Figure A.4e-13. Transect T330 secondary wetted perimeter vs flow. Figure A.4e-14. Transect T330 secondary wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 8 June 2014 Figure A.4e-15. Transect T330 secondary hydraulic radius vs flow. Figure A.4e-16. Transect T330 secondary average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 9 June 2014 Figure A.4e-17. Transect T330 Tertiary wetted perimeter vs flow. Figure A.4e-18. Transect T330 tertiary wetted width vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4e Page 10 June 2014 Figure A.4e-19. Transect T330 tertiary hydraulic radius vs flow. Figure A.4e-20. Transect T330 tertiary average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 4f Reach 4 This sub-appendix contains the following figures: Figure A.4f-1. Transect 400 bed profile and WSE, 10–1,000 cfs. Figure A.4f-2. Transect T410 bed profile and WSE, 10–1,000 cfs. Figure A.4f-3. Transect T430 bed profile and WSE, 10–1,000 cfs. Figure A.4f-4. Reach 4 wetted perimeter vs flow. Figure A.4f-5. Reach 4 wetted width vs flow. Figure A.4f-6. Reach 4 hydraulic radius vs flow. Figure A.4f-7. Reach 4 average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4f Page 1 June 2014 Figure A.4f-1. Transect 400 bed profile and WSE, 10–1,000 cfs. Figure A.4f-2. Transect T410 bed profile and WSE, 10–1,000 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4f Page 2 June 2014 Figure A.4f-3. Transect T430 bed profile and WSE, 10–1,000 cfs. Figure A.4f-4. Reach 4 wetted perimeter vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4f Page 3 June 2014 Figure A.4f-5. Reach 4 wetted width vs flow. Figure A.4f-6. Reach 4 hydraulic radius vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 4f Page 4 June 2014 Figure A.4f-7. Reach 4 average depth vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5: Weighted Usable Area Graphs Appendix 5a. Reach 1 Main Channel WUA Appendix 5b. Reach 1 Side Channel WUA Appendix 5c. Reach 2 WUA Appendix 5d. Reach 3 Main Channel WUA Appendix 5e. Reach 3 Side Channel WUA Appendix 5f. Reach 4 WUA FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5a. Reach 1 Main Channel WUA This sub-appendix contains the following figures: Figure A.5a-1. Transect T120 WUA, spawning. Figure A.5a-2. Transect T120 WUA, fry rearing. Figure A.5a-3. Transect T120 WUA, adult and juvenile rearing. Figure A.5a-4. Transect T130 WUA, spawning. Figure A.5a-5. Transect T130 WUA, fry rearing. Figure A.5a-6. Transect T130 WUA, adult and juvenile rearing. Figure A.5a-7. Transect T140 WUA, spawning. Figure A.5a-8. Transect T140 WUA, fry rearing. Figure A.5a-9. Transect T140 WUA, adult and juvenile rearing. Figure A.5a-10. Transect T150 WUA, spawning. Figure A.5a-11. Transect T150 WUA, fry rearing. Figure A.5a-12. Transect T150 WUA, adult and juvenile rearing. Figure A.5a-13. Transect T160 WUA, spawning. Figure A.5a-14. Transect T160 WUA, fry rearing. Figure A.5a-15. Transect T160 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 1 June 2014 Figure A.5a-1. Transect T120 WUA, spawning. Figure A.5a-2. Transect T120 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 2 June 2014 Figure A.5a-3. Transect T120 WUA, adult and juvenile rearing. Figure A.5a-4. Transect T130 WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 3 June 2014 Figure A.5a-5. Transect T130 WUA, fry rearing. Figure A.5a-6. Transect T130 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 4 June 2014 Figure A.5a-7. Transect T140 WUA, spawning. Figure A.5a-8. Transect T140 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 5 June 2014 Figure A.5a-9. Transect T140 WUA, adult and juvenile rearing. Figure A.5a-10. Transect T150 WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 6 June 2014 Figure A.5a-11. Transect T150 WUA, fry rearing. Figure A.5a-12. Transect T150 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 7 June 2014 Figure A.5a-13. Transect T160 WUA, spawning. Figure A.5a-14. Transect T160 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5a Page 8 June 2014 Figure A.5a-15. Transect T160 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5b. Reach 1 Side Channel WUA This sub-appendix contains the following figures: Figure A.5b-1. Transect T100 WUA, spawning. Figure A.5b-2. Transect T100 WUA, fry rearing. Figure A.5b-3. Transect T100 WUA, adult and juvenile rearing. Figure A.5b-4. Transect T110 WUA, spawning. Figure A.5b-5. Transect T110 WUA, fry rearing. Figure A.5b-6. Transect T110 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5b Page 1 June 2014 Figure A.5b-1. Transect T100 WUA, spawning. Figure A.5b-2. Transect T100 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5b Page 2 June 2014 Figure A.5b-3. Transect T100 WUA, adult and juvenile rearing. Figure A.5b-4. Transect T110 WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5b Page 3 June 2014 Figure A.5b-5. Transect T110 WUA, fry rearing. Figure A.5b-6. Transect T110 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5b Page 4 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5c. Reach 2 WUA This sub-appendix contains the following figures: Figure A.5c-1. Transect T200 WUA, spawning. Figure A.5c-2. Transect T200 WUA, fry rearing. Figure A.5c-3. Transect T200 WUA, adult and juvenile rearing. Figure A.5c-1. Transect T220 WUA, spawning. Figure A.5c-2. Transect T220 WUA, fry rearing. Figure A.5c-3. Transect T220 WUA, adult and juvenile rearing. Figure A.5c-4. Transect T230 WUA, spawning. Figure A.5c-5. Transect T230 WUA, fry rearing. Figure A.5c-6. Transect T230 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5c Page 1 June 2014 Figure A.5c-1. Transect T200 WUA, spawning. Figure A.5c-2. Transect T200 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5c Page 2 June 2014 Figure A.5c-3. Transect T200 WUA, adult and juvenile rearing. Figure A.5c-4. Transect T220 WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5c Page 3 June 2014 Figure A.5c-5. Transect T220 WUA, fry rearing. Figure A.5c-6. Transect T220 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5c Page 4 June 2014 Figure A.5c-7. Transect T230 WUA, spawning. Figure A.5c-8. Transect T230 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5c Page 5 June 2014 Figure A.5c-9. Transect T230 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5c Page 6 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5d. Reach 3 Main Channel WUA This sub-appendix contains the following figures: Figure A.5d-1. Transect T300 WUA, spawning. Figure A.5d-2. Transect T300 WUA, fry rearing. Figure A.5d-3. Transect T300 WUA, adult and juvenile rearing. Figure A.5d-4. Transect T310 WUA, spawning. Figure A.5d-5. Transect T310 WUA, fry rearing. Figure A.5d-6. Transect T310 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5d Page 1 June 2014 Figure A.5d-1. Transect T300 WUA, spawning. Figure A.5d-2. Transect T300 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5d Page 2 June 2014 Figure A.5d-3. Transect T300 WUA, adult and juvenile rearing. Figure A.5d-4. Transect T310 WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5d Page 3 June 2014 Figure A.5d-5. Transect T310 WUA, fry rearing. Figure A.5d-6. Transect T310 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5d Page 4 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5e. Reach 3 Side Channel WUA This sub-appendix contains the following figures: Figure A.5e-1. Transect T320 WUA, spawning. Figure A.5e-2. Transect T320 WUA, fry rearing. Figure A.5e-3. Transect T320 WUA, adult and juvenile rearing. Figure A.5e-4. Transect T330 primary WUA, spawning. Figure A.5e-5. Transect T330 primary WUA, fry rearing. Figure A.5e-6. Transect T330 primary WUA, adult and juvenile rearing. Figure A.5e-7. Transect T330 secondary WUA, spawning. Figure A.5e-8. Transect T330 secondary WUA, fry rearing. Figure A.5e-9. Transect T330 secondary WUA, adult and juvenile rearing. Figure A.5e-7. Transect T330 tertiary WUA, spawning. Figure A.5e-8. Transect T330 tertiary WUA, fry rearing. Figure A.5e-9. Transect T330 tertiary WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5e Page 1 June 2014 Figure A.5e-1. Transect T320 WUA, spawning. Figure A.5e-2. Transect T320 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5e Page 2 June 2014 Figure A.5e-3. Transect T320 WUA, adult and juvenile rearing. Figure A.5e-4. Transect T330 primary WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5e Page 3 June 2014 Figure A.5e-5. Transect T330 primary WUA, fry rearing. Figure A.5e-6. Transect T330 primary WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5e Page 4 June 2014 Figure A.5e-7. Transect T330 secondary WUA, spawning. Figure A.5e-8. Transect T330 secondary WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5e Page 5 June 2014 Figure A.5e-9. Transect T330 secondary WUA, adult and juvenile rearing. Figure A.5e-10. Transect T330 tertiary WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5e Page 6 June 2014 Figure A.5e-11. Transect T330 tertiary WUA, fry rearing. Figure A.5e-12. Transect T330 tertiary WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 5f. Reach 4 WUA This sub-appendix contains the following figures: Figure A.5f-1. Transect T400 WUA, spawning. Figure A.5f-2. Transect T400 WUA, fry rearing. Figure A.5f-3. Transect T400 WUA, adult and juvenile rearing. Figure A.5f-4. Transect T410 WUA, spawning. Figure A.5f-5. Transect T410 WUA, fry rearing. Figure A.5f-6. Transect T410 WUA, adult and juvenile rearing. Figure A.5f-7. Transect T430 WUA, spawning. Figure A.5f-8. Transect T430 WUA, fry rearing. Figure A.5f-9. Transect T430 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5f Page 1 June 2014 Figure A.5f-1. Transect T400 WUA, spawning. Figure A.5f-2. Transect T400 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5f Page 2 June 2014 Figure A.5f-3. Transect T400 WUA, adult and juvenile rearing. Figure A.5f-4. Transect T410 WUA, spawning. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5f Page 3 June 2014 Figure A.5f-5. Transect T410 WUA, fry rearing. Figure A.5f-6. Transect T410 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5f Page 4 June 2014 Figure A.5f-7. Transect T430 WUA, spawning. Figure A.5f-8. Transect T430 WUA, fry rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5f Page 5 June 2014 Figure A.5f-9. Transect T430 WUA, adult and juvenile rearing. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 5f Page 6 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 6: Reach 5 Connectivity Appendix 6a. Reach 5 Bed Profiles and Water Surface Elevation (WSE) Appendix 6b. Reach 5 Rainbow Trout and Dolly Varden Passage Appendix 6c. Reach 5 Coho and Sockeye Salmon Passage Appendix 6d. Reach 5 Chinook Salmon Passage FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 6a. Reach 5 Bed Profiles and Water Surface Elevation (WSE) This sub-appendix contains the following figures: Figure A.6a-1. Transect T510 bed profile and Water Surface Elevation (WSE), 7–300 cfs. Figure A.6a-2. Transect T520 bed profile and WSE, 7–300 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6a Page 1 June 2014 Figure A.6a-1. Transect T510 bed profile and Water Surface Elevation (WSE), 7–300 cfs. Figure A.6a-2. Transect T520 bed profile and WSE, 7–300 cfs. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6a Page 2 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 6b. Reach 5 Rainbow Trout and Dolly Varden Passage This sub-appendix contains the following figures: Figure A.6b-1. Transect T510 rainbow trout and Dolly Varden passage vs flow. Figure A.6b-2. Transect T520 rainbow trout and Dolly Varden passage vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6b Page 1 June 2014 Figure A.6b-1. Transect T510 rainbow trout and Dolly Varden passage vs flow. Figure A.6b-2. Transect T520 rainbow trout and Dolly Varden passage vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6b Page 2 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 6c. Reach 5 Coho and Sockeye Salmon Passage This sub-appendix contains the following figures: Figure A.6c-1. Transect T510 coho and sockeye salmon passage vs flow. Figure A.6c-2. Transect T520 coho and sockeye salmon passage vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6c Page 1 June 2014 Figure A.6c-1. Transect T510 coho and sockeye salmon passage vs flow. Figure A.6c-2. Transect T520 coho and sockeye salmon passage vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6c Page 2 June 2014 [This page intentionally left blank.] FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 June 2014 Appendix 6d. Reach 5 Chinook Salmon Passage This sub-appendix contains the following figures: Figure A.6d-1. Transect T510 Chinook salmon passage vs flow. Figure A.6d- 2. Transect T520 Chinook salmon passage vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6d Page 1 June 2014 Figure A.6d-1. Transect T510 Chinook salmon passage vs flow. Figure A.6d- 2. Transect T520 Chinook salmon passage vs flow. FINAL REPORT AQUATIC RESOURCES – HABITAT MAPPING / INSTREAM FLOW STUDY Grant Lake Hydroelectric Project Kenai Hydro, LLC FERC No. 13212 Appendix 6d Page 2 June 2014 [This page intentionally left blank.]