Loading...
HomeMy WebLinkAboutNative Village of Minto 10.8 kW Production9/30/2015 PVW atts Calculator http://pvwatts.nr el.gov/pvwatts.php 1/1 Caution: Photovoltaic system performance predictions calculated by PVWatts® include many inherent assumptions and uncertainties and do not reflect variations between PV technologies nor site­specific characteristics except as r epresented by PVWatts® inputs. For  example, PV modules with better perfor mance are not differentiated within PVWatts® from lesser perfor ming modules. Both NREL and pr ivate companies provide more sophisticated PV modeling tools (such as the System Advisor  Model at http://sam.nrel.gov) that allow for more pr ecise and complex modeling of PV systems.   Disclaimer: The PVWatts® Model ("Model") is pr ovided by the National Renewable Energy Laboratory ("NREL"), which is operated by the Alliance for Sustainable Energy, LLC ("Alliance") for the U.S. Department Of Ener gy ("DOE") and may be used for any pur pose whatsoever. The names DOE/NREL/ALLIANCE shall not be used in any representation, advertising, publicity or  other manner whatsoever to endorse or pr omote any entity that adopts or uses the Model. DOE/NREL/ALLIANCE shall not pr ovide any suppor t, consulting, training or assistance of any kind with regar d to the use of the Model or any updates, revisions or new versions of the Model. YOU AGREE TO INDEMNIFY DOE/NREL/ALLIANCE, AND ITS AFFILIATES, OFFICERS, AGENTS, AND EMPLOYEES AGAINST ANY CLAIM OR DEMAND, INCLUDING REASONABLE ATTORNEYS' FEES, RELATED TO YOUR USE, RELIANCE, OR ADOPTION OF THE MODEL FOR ANY PURPOSE WHATSOEVER. THE MODEL IS PROVIDED BY DOE/NREL/ALLIANCE "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL DOE/NREL/ALLIANCE BE LIABLE FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO CLAIMS ASSOCIATED WITH THE LOSS OF DATA OR PROFITS, WHICH MAY RESULT FROM ANY ACTION IN CONTRACT, NEGLIGENCE OR OTHER TORTIOUS CLAIM THAT ARISES OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE MODEL. 11,411 kWh per Year *RESULTS Month Solar Radiation ( kWh / m2 / day ) AC Energy ( kWh ) Energy Value ( $ ) January 0.64 210 130 February 2.05 593 368 March 4.11 1,259 781 April 5.61 1,604 995 May 5.58 1,552 962 June 5.75 1,517 941 July 5.53 1,487 922 August 4.58 1,257 780 September 3.37 923 572 October 2.01 607 376 November 0.95 296 183 December 0.32 104 65 Annual 3.38 11,409 $ 7,075 Location and Station Identification Requested L ocation 101 Lakeview St, Minto AK Weather Data Source (TMY2) FAIRBANKS, AK  49 mi Latitude 64.82° N Longitude 147.87° W PV System Specifications (Residential) DC System Size 10.8 kW Modu le Type Standard Array Type Fixed (open rack) Array Tilt 45° Array Azimuth 180° System Losses 11% Inverter Efficiency 96% DC to AC Size Ratio 1.1 Initial Economic Comparison Average Cost of Electricity Purchased from Utility 0.62 $/kWh Initial Cost 3.30 $/Wdc Cost of Electricity Generated by System 0.25 $/kWh These values can be compared to get an idea of the cost­effectiveness of this system. However, system costs, system financing options (including 3rd party ownership) and complex utility rates can significantly change the relative value of the PV system.