HomeMy WebLinkAboutInverter & Solar Module SpecificationsFronius IG Plus Advanced PV Inverter
The world's first high frequency inverter with arc -fault circuit interruption (AFCI).
An outstanding addition to the family: The next
generation of field serviceable Fronius IG Plus Advanced
inverters include industry first Arc Fault Protection in a
High Frequency inverter, Advanced Grid Features for
Smart Grid integration, built in Corn Card for data
communications, and DC connecting distributors
included with all three power stage inverters. Add these
to our impressive list of standard features including a
built-in six circuit string combiner, integrated lockable
DC Disconnect, multiple power stage MixTechnology
with "Power on Demand"and built in
redundancy,lightest and best looking in class satin
finished aluminum NEMA 311 housing with Power Plug
system for easy installation
AV
POWERING YOUR FUTURE
INPUT DATA Fronius IG Plus A
3.0-1 uN
3.8-1 uNI
5.0-1 uNi
1 6.0-1 uNi
7.5-1 uNl
10.0-1 uNi
11.4-1 uNI
10.0-3 �1.
11.4-3 aeon
12.0-3 WYE277
Recommended PV-Power(kWp}
2.50-3.45
3.20-4.40
4.25-5.75
5.10-6.90
6.35-8.60
8.50-11.50
9.70-13.10
8.50-11.50
9.70-13.10
10.20-13.80
MPPT-voltage range 230 ... 500 V
DC startup voltage 245 V
ix. Input voltage Iat10t10 W/m'
'F 00'Q in open circuit operation) 600 V
Nominal input current
B.3 A
10.5 A
13.8 A
16.5 A
20.7 A
27.6 A
31.4 A
27.6 A
31.4 A
33.1 A
Max. usable input current
14.0 A
17.8 A
23.4 A
I 28.1 A
I' 35.1 A I
46.7 A
53.3 A
I 46.7 A
53.3 A
I 56.1 A
Admissible conductor size (DC) No. 14 - 6 AWG
Number of DC input terminals 6
Max. current per DC input terminal 20 A; Sus bar available for higher input currents
OUTPUT DATA Fronius IG Plus A
3.0-1 u,,
3.8-1 uN,
5.0-1 uNi
1 6.0-1 uni
7.5-1 uw
1010-1 uNi
11.4-1 uwi
10.0-3 oem
11.4-3 oeiu
12.0-3 wrr�n
Nominal output power (P,, am }
3000 W
3800 W
5000 W
6000 W
7500 W
9995 W
11400 W
9995 W
11400 W
12000 W
Max. continuousoutput power
104 -F t40 -Q 208 V / 240 V / 277 V
3000 W
3800 W
5000 W
6000 W
7500 W
9995 W
11400 W
9995 W
11400 W
12000 W
Nominal AC output voltage
208V/240V/277V
208V7240V
277V
Operating AC voltage range 2013V
183 - 229 V (-121+10 %)
(default) 240 V
211 - 264 V (-12 / +10 %)
277 V
244 - 305 V (-12 / +10 %)
Max. continuous 208 V
14.4 A
1 B.3 A
24.0 A
28.B A
36.7 A
48.1 A
54.8 A
27.7 A*
31.6 A*
n.a.
output current 240 V
12.5 A
15.8 A
20.8 A
25.0 A
31.3 A
41.6 A
47.5 A
24.0 A*
27.4 A*
n.a.
277 V
10.8 A
13.7 A
18.1 A
21.7 A
27.1 A
36.1 A
41.2 A
n.a
n.a.
14.4 A*
Numberof phases
1
3
Admissible conductor size (AC)
No. 14 - 4 AWG
Max. continuous utility back feed current
0 A
Nominal output frequency
60 Hz
Operating frequency range
59.3 -60.5 Hz
Total harmonic distortion
< 3 %
Power factor
1 (at nominal output power)
`ENERAL DATA Fronius lG Plus Al
3.0-1 uNi I
3.8-1 -
5.0-1 uNi
6.0-1 uNi
i 7.5-1 um
10.0-1 uNi I
11.4-1 uNI
10.0-3 oew. I
11.4-3 D.I.
112.0-3 w 277
.lax. efficiency
96.2 %
CEC efficiency 208V
95.0%
95.0%
955%
95.%%
95.0%
95.0%
95.0%
95.0%
95.0%
n.a.
240 V
95.5 %
95.5 %
95.5 %
96.0 %
95.5 %
95.5 %
95.5 %
96.0%
96.0%
n.a.
277 V
96.0 %
96.0 %
96.0 %
96.0 %
96.0 %
96.0 %
96.0 %
n.a
n.a.
96.0 %
Consumption in standby (night)
< 1.5 W
Consumption during operation
8 W
14 W
20 W
Cooling
Controlled forced ventilation, variable
speed fan
Enclosure type NEMA 3R
Unit dimensions (W x H x D)
17.1 x 26.5 x 9.9 In.
17.1 x 3B.1 x 9.9 in.
17.1 x 49.7 x 9.9 in.
Power stack weight
31 lbs. (14 kg)
57 lbs. (26 kg)
84lbs. (38 kg)
Wiring compartment weight
241bs. (11 kg)
24lbs. (11 kg)
261bs. (12 kg)
Admissible ambient operating temperature -13'F ... +131 °F (-25 °C ... +55'Q
Compliance UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A & Br NEC Article 690, C22.2 No.107.1-01 (Sept.2001)
California Solar Initiative - Program Handbook -Appendix C: inverter Integral 5 %Meter Performance Specification
PROTECTION
DEVICES Fron ius fG Plus 3.0-1 uNi 3.9-1 uNi 5.0-1 urvi 6.0-1 uNi 7.5-1 N 10.0-1 11.4-1 N 10.0-3 11.4-3 12.0-3 wvr n
Ground fault protection Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2010 and NEC Art. 690
DC reverse polarity protection Internal diode
Islanding protection Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC
Over temperature Output power derating / active cooling
Arc -Fault Circuit Protection Internal AFCI (Arc -Fault Circuit Interrupter); detects and interrupts series arcing faults in the DC circuits
* perPhase
Fronius USA, LLC
6797 Fronius Drive
Portage, IN 46369
www.fronius-usa.com
KLKD SERIES 1008 mm FUSES
600 VAC/600 VDC a Fast Acting
Description
The KLKD fuse series is fast -acting with a high DC voltage
rating.This family of Midget style fuses (10 x 38 mm) is used
in solar combiner boxes and in circuits with DC fault currents
up to 50,000 amperes. KLKD fuses are available in standard
and board -mount configurations.
In addition, the KLKD series has been designed to meet both
the UL and IEC photovoltaic fuse standards.
Littelfuse offers a wide range of ampere ratings to match
specific requirements in a variety of applications-
FeatureslBenefits
• Designed to UL and IEC photovoltaic specifications
1/10-30 A ratings avaHable
• 50 kA DC Voltage Interrupting Rating (7/10-3D A)
• Both standard and board -mount configurations available
• 1-5 A meets UL1747 GFDI requirements
Recommended Fuseholders
LPSM Series
L60030M Series
L6003OMPCB Board Mount Holder
Applications
• Combiner boxes
• Inverters
• Power supplies
• Desktop meters
• 600 V circuit protection
Look for this logo to indicate products that are
® used in solar applications. Visit our vvebsite
wvvw.fittelfuse.com/solar for the latest updates
on approvals, certifications, codes and standards.
uL P-MM & C E 9PV iOHS
Specifications
Voltage Rating:
600VAC/VDC
Amperage Rating:
1/10,1/8, 2/10, 1/4, 3/1D, 1/2, 3/4, 1, 11/2, 2, 21/2, 3,
31/7, 4, 5, 6, Z 8, 9,10, 12,15, 20, 25, 30
Interrupting Ratings:
AC:100 kA
DC: IN-30: 10 kA(UL 2579)
Ihi)-30: 50 kA (UL 240-14)
Material:
Body: Melamine
Caps: Copper Alloy
Operating Temperature:
See Rerating Curve
Approvals:
Vin-30 A UL 2579 Listed (File No. E339117)
2-25 A IEC 60269-6
(VDEApproved to Certifications No.40033994)
UL248-14 Listed (File No. E10480)
C5A Certified (File No. LH29862)
(1/To-30 A Ferrule Style Only)
CE Certified
Environmental:
ROFIS Compliant
Country of Origin:
Mexico
Ordering Examples
AMPERAGE
PARTNUMBER
ORDERING NUMBER
1/11
KLKD125
KLKD.12ST
1
KLK0001
KLKDO013
2
KLKDU02
If LK0002.T
0
KLK0008
KLK0008.1
30(WITH FC8TABS)
KLKW30R
KLK0030HM
Dimensions in inches(mm)
Ferrule Version
PCs version
I— 05 11.521
.02 L571
14
;3.56}—I tL
n.Dz}
1.5 {38.1 i
1.53
tas-ss1
50;12.71
.1213.D51
MOUNTING HOLE
DETAIL
11U-311
laAsl{llli 406(10.31)
Web Resources
Downloadable CAD drawings and other technical information:
www.lifteffuse.com/klkd
tiwvw.littelf.se.com 1 Q November 2011 tittelfuse POVVR-GARO Products
Battery Charging Systems / Welding Technology / Solar Electronics
SHIFTING THE LIMITS
Fronius USA Premium Warranties
Fronius USA Premium Standard 14-Year Warranty
The Fronius USA Premium 10-Year Warranty applies to the following products:
• Fronius IG Series Inverters - IG 20001 IG 250OLV / IG 3000 / IG 40001 IG 450OLV / IG 5100
• Fronius IG Plus Series Inverters - &0-1 uN, / 3.8-1 uN, / 5.0-1 uNJ / 6.0-1 uN, / 7.5-1 uNl / 10.0-1 uN, / 11.4-1 uN, I
11.4-3L,elta / IG 12-0-3NlYE277
• Fronius IG Plus V Series Inverters - 3.0-1 uN, / 3- 8-1 uN, / 5.0-1 uN,16.0-1 uNI / 7.5-1 UNI / 10.0-1 uN, / 11.4-1 uN, /
10.0-3pe,l 1 11.4-3pe,ta /IG 12-0-3wYE277
• Fronius CL Series - PV Central Inverters - CL 33.3 / CL 36.0 / CL 44.4 / CL 48.0 / CL 55.51 CL 60.0
Fronius Premium Extended Warranties
Fronius USA Premium 5-Year Extended Warranty applies to the following products:
• Fronius IG Series Inverters - IG 2000 / IG 250OLV / IG 30001 IG 4000 I IG 450OLV / IG 5100
• Fronius IG Plus Series Inverters - 3.0-1 uNI / 3.8-1 uNi / 5.0-1 uN, / 6- 0-1 uNI 17.5-1 uNi / 10-0-1 UN, / 11.4-1 uNi I
11.4-3oeita 1 IG 12-0-3wvE277
• Fronius IG Plus V Series Inverters - 3.0-1 uN, / 3.8-1 uN, / 5.0-1 uN, 16.0-1 uN, / 7.5-1 uN, 110.0-1 uN, / 11.4-1 uN,1
10.0-3oeita 111.4-3pei, /IG 12-0-3wYE277
Fronius USA Premium 10-Year Extended Warranty applies to the following products:
• Fronius IG Series Inverters - IG 2000 / IG 250OLV / IG 3000 / IG 40001 IG 450OLV / IG 5100
• Fronius IG Plus Series Inverters - 3.0-1 uN, 13.8-1 uN, / 5.0-1 UK / 6.0-1 uN,17.5-1 W / 10.0-1 UM / 11.4-1 uNI 1
11.4-3oe,ta / IG 12-0-3wvE277
• Fronius IG Plus V Series inverters - 3.0-1 UN, 13.8-1 UN, / 5.0-1 uN, 16.0-1 uNE / 7.5-1 UN, / 10,0-1 uN, 11.4-1 uN, /
10,0-31),&, / 11.4-3D61t /IG 12-0-31NYE277
• Fronius CL Series _PV Central Inverters - CL 33.3 1 CL 36.0 / CL 44.4 / CL 48.0 1 CL 55.5 / CL 60.0
Please contact your Fronius Authorized Distributor or Integrator. The purchase the Fronius Premium 5 or 10-Year
Warranty Extension must be done through your Solar Dealer or Installer whom will forward the details to the
Fronius Authorized Distributor or directly to Fronius if they are a direct account of Fronius. See the Fronius USA 5-
Year and 10-Year Warranty Extension document for further details. You can download this document from
www.fronius-usa.com.
0112011
113
Battery Charging Systems / Welding Technology / Solar Electronics
i
SHIFTING THE LIMITS
✓ if troubleshooting does not fix the problem, the following information will be required by the Technical
Support Representative for the RMA application. The representative will collect this information over the
phone:
1. Model and Serial Number of the FRONIUS Solar Inverter.
2. Detailed description of the problem including the Inverter's diagnostic code(s).
3. Shipping address for the warranty replacement equipment.
4. When the replacement inverter will be required.
Note: Failure to contact Fronius Technical support in advance of conducting service on any Fronius
product will result in no service compensation being paid.
Once the RMA has been issued:
✓ Fronius USA will ship a replacement inverter or part ahead to the installer and every reasonable effort
will be made to ship the replacement within the specified time as per point #4 above. Fronius will prepay
the shipping costs.
✓ When the replacement inverter or part arrives and is installed, the installer simply places the defective
item into the box from the replacement item.
• Apply the included UPS call tag to the box and call UPS.
• The defective inverter must be returned to Fronius USA within 14 days of receiving the replacement
unit or a charge may be applied for the replacement. No service reimbursement will be issued until
the product is returned.
• All FRONIUS Solar Inverters authorized for return by Fronius USA must be returned in its original
shipping container or packaging providing equal protection.
Warranty period for any repaired or replaced inverter: 12 months after shipment from Fronius USA or the
original remaining warranty period, whichever is greater.
Service reimbursement: Fronius offers a service reimbursement amount of $250.00 per qualifying RMA.
Damage caused by shipping or mishandling: Visually evident damage caused by shipping or mishandling is to
be reported to the freight carrier within 24 hours. Shipping damage is the responsibility of the freight carrier, not
Fronius, and should always be duly noted with the freight carrier prior to accepting and signing for the product.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights, which vary from state to state. Fronius USA, LLC
General Terms and Conditions also apply.
Additional Information: Contact your local Solar Dealer, Fronius Distribution Partner, or Fronius for additional
information on the Fronius 10-Year Premium Warranty. Additional resources may also be found on the Fronius USA
Solar web site www.fronius-usa.com, including information on service assistance, online training, accessories,
product information, or product manuals.
You may also contact Fronius Directly: Fronius Technical Support is available 6am to 6pm (P.S.T.) Monday
through Friday excluding holidays and weekends by appointment only at 810-220-4414.
V. t .2012
Fronius USA, LLC
10421 Citation Drive, Ste. 1100
Brighton, MI 48116
Ph. 810-220-4414
E-Mail: pv-support-usa@fronius.com
wv.w.fronius.com
OV2011 3/3
///PEIMAR
EU S-GREEN LINE.
SG250P 1 SG260P 1 SG270P
S
O High
5W power oiutput tolerance
-00,
30 Year Linear Power
12 Year P oduct Warranty
`: � Excellent
different light
light
conditions
x
IIP6
IP65 JUNCTION BOX "
Able to withstand the most varied
Passing mechanical load test of
5400 Pa to.vrithstand heavier snow
Compact and ultra -light aluminum
frame with 40mm, thickness to
atmospheric conditions
load and 24O0 Pa to withstand
handle the panel in a easier spray
wind pressure
/// CL.CL I Lr11AF%A%, I ERIaZ I IIrJ (J 14J
b"Zz1Vr buldOut
S(jZfUF°
Nominal Output (Pmax) [W]
250 260
270
Flash Test Power Classification [W]
01 +5 0 / +5
01 +5
Voltage at Pmax (Vmp) [V]
30.4 30.6
30.8
Current at Pmax (Imp) [A]
8.23 8.50
8.77
Open Circuit Voltage (Voc) [V]
36.5 36.8
37.2
Short Circuit Current (Isc) [A]
9.21 9.52
9.82
Maximum System Voltage [V]
1000
Maximum Series Fuse Rating [Al
15 15
15
Cell Efficiency [%]
17.12 17.81
18.49
Module Efficiency [%]
W
15-37 15.98
�16.60
STC` (Standard Test Condition): Irradiance 1000Wlm', Module Temperature 25'C, Air Mass 1.5
/®/ MECHANICAL CHARACTERISTICS
/// TEMPERATURE CHARACTERISTICS
Solar Cells 60(6x10) poly -crystalline cells 156x156 mm
NOCT**
45±2 °C
Font Cover 3.2 mm thick, low iron tempered glass
Temperature Coefficient of Pmax
-0.43 %/°C
Back Cover TPT (Tedlar-PET-Tedlar)
Temperature Coefficient of Vac
-0.32 %/°C
Encapsulant EVA (Ethylene vinyl acetate)
Temperature Coefficient of Isc
0.047 %1°C
Frame Anodized aluminium alloy, double wall
Operating Temperature
-40°C — +85°C
Diodes 3 Bypass diodes serviceable
NOCT"": Nominal Operation Cell Temperature Sun 800Wflrl'; Air 20'C; Wind speed 1 rods
Junction Box IP65 rated
Z11 PACKING CONFIGURATION
Connector MC4 or compatible connector
Pallet dimensions 1700 x 1100 x 1200 mm
Cables Length: 900 mm / Section: 4.0 mm2
Pieces per pallet
27 pcs
Dimensions 1640 x 992 x 40 mm
Weight
616 kg
Weight 18 kg
Pallets can be stacked up to two
Max. Load Certified to 5400 Pa
®O/ CURRENT l VOLTAGE CHARACTERISTICS*
®// DIMENSIONS
_�aoo wpm°
992
~ 942
Wfm'
6 - - Boo wim'
m ..._
U
\
4 400 Won'
------ .........
2 200 W!m'
It
v
5 10 15 20 25 30
35 40
Voltage (Vy
Module temperature: 25'C
010
0 C3 o m
m00
r r
_
_
6
m
1Goo WIM2 at 251C
-
U 4........... 1Goo Wlrrt2.at"5o,C., ,_..
1000 Wlms at 0°C
0 5 10 15 20 25 30
35 40 45
Voltage M
The above values apply to 502501'
PEIMAR GROUP
t re
Italy Oa Via Greta G 25124 -Brescia -Italy - Phone t39 e0-223292
USA Office East Coast: One Gateway Cerrsay Suite 2600 07102 Newark, NJ - USA - Phone: •1973-799-#547
A
� MAR
USA Offiffs ce Westaet Coast:t: soap center
E-mail: idol etmarwm
Dove, 9ga45 Los Angeteb. CA USA -Phone: +1 310daM7334
'
Web: www mar earn
❑
It is Important to point out, that all teahni al speefleatiens,intormalion and figuras Contained in this dwasheet are estimated
in This document at any tlme and Vdihoul notice.
values. Peimar reserves the ¢ght to chafe the technical speciFications,
i�wmation andfigurescontained