ATT B BID DOCS
CONTRACT DOCUMENTS AND SPECIFICATIONS FOR CONSTRUCTION OF CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA Prepared for: Atka Electric Utility 721 Sesame St, Suite 2C Anchorage, AK 99503-6632 Prepared by: Polarconsult Alaska, Inc. 1503 W 33rd Ave #310 Anchorage, AK 99503 TABLE OF CONTENTS BID DOCUMENTS Bid Information Invitation for Bids Instructions for Bidders Bid Form Bid Bond Notice of Award Contract AEU Contractor Agreement { a Contract Forms Contract Bond (Payment) Contract Bond (Performance) Corporate Acknowledgment (for Contract) General Conditions (68 Pages) Supplemental Conditions (2 Pages) Appendix Work Change Directive Form Change Order Form Field Order Form Minimum Rates of Pay Davis Bacon Wage Determinations Geotechnical Information Project Drawings INVITATION FOR BIDS CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA INVITATION TO BID The Atka Electric Utility (AEU) herby invites qualified firms to submit a firm price for acceptance by for construction of the Chuniisax Hydroelectric Dispactable Energy in Atka, Alaska. The Chuniisax Hydroelectric Dispactable Energy Project consists of the supplying all materials, equipment, and labor to install electric heating units and connection to existing hydronic heating systems, duplex electric meter bases, and controls in 6 existing buildings, and programming exiting hydroelectric plant controls to provide dispatched energy to the 6 existing buildings and all other associated work as described in the design documents. The hydroelectric power plant and controls was constructed in 2012 and are currently in operation providing electric power to the community of Atka. Bids shall be on a stipulated (lump) sum basis. Segregated bids will not be accepted. Project is to be substantially completed by , 2014 Sealed bids are due at 5:00 PM AST, _, _ 2014 at the following location: Atka Electric Utility c/o Polarconsult, Alaska Inc. 1503 W. 33"' Avenue, Suite 310 Anchorage, Alaska 99503 Tel (907) 258-2420 Fax (907) 258-2419 Any Bids received after the time and date specified will not be considered. Bids will be opened publicly and read aloud immediately after the specified closing time. All interested parties are invited to attend. Owner Atka Electric Utility 721 Sesame St, Suite 2C Anchorage, AK 99503-6632 Bid Requirements Bidders must be licensed and bonded contractors within the State of Alaska. The successful bidder shall sign a contract with Atka Electric Utility. No bid may be withdrawn after the time for opening. The bidder must comply with all laws and regulations. Complete bidding documents for this project are available only in electronic form. They may be viewed online and downloaded without charge and without deposit from www.—.com and are available at your local plan rooms and reprographers. Bidders must register through the website to be notified of addenda. Bid documents are not available from the Engineer, but may be obtained from most plans rooms and reprographic firms for a fee. Plan holders are responsible for their own reproduction costs. Addenda to the project will be posted on the website. The bidder is responsible for periodically checking the site. The Contractor that is awarded the project will be responsible for printing all documents necessary for performing the work. Michael Dahl, PE, Project Manager Polarconsult, Alaska Inc. 1503 West 33 d Avenue, Suite 310 Anchorage, Alaska 99503 Tel (907) 258-2420 Fax (907) 258-2419 Publish: Anchorage Daily News: Dates: XXXXX Alaska Newspapers Inc: Dates: XXXXX Daily Journal of Commerce: Dates: XXXXX CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA INSTRUCTIONS TO BIDDERS CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA INSTRUCTIONS TO BIDDERS TABLE OF CONTENTS Article 1 — Defined Terms.................................................................... INSTRUCTIONS TO BIDDERS Article 2 — Copies of Bidding Documents........................................................... Article 3 — Qualifications of Bidders................................................................... Article 4 — Examination of Bidding Documents, Other Related Data, and Site Article 5 — Pre -Bid Conference............................................................................ Article 6 — Site and Other Areas Article 7 — Interpretations and Addenda Article 8 — Bid Security .......................... Article 9 — Contract Times..........................................................................1.7.................... 1 Article 10 —Liquidated Damages.............................................................. Article 11 —Substitute and "Or -Equal" Items ................................... Article 12 — Subcontractors, Suppliers and Others ............................ . / ......... Article 13 — Preparation of Bid..............................................................................:::.r ..... Article 14 — Basis of Bid; Comparison of Bids ................................. ', r € Article 15 —Submittal of Bid............................................................. �.. 4Z Article 16 — Modification and Withdrawal of Bid ............................................. ',:......... Article 17 — Opening of Bids............................................................ ..... .......c......... J Article 18 — Bids to Remain Subject to Acceptance .......... Article 19 — Evaluation of Bids and Award of Contract.... ...... ......... Article 20 — Contract Security and Insurance ............................... s''.......... .............. Article 21 — Signing of Agreement .............................................. ' .............. Article 22 — Sales and Use Taxes....................................................................................... Article 23 — Retainage ........................ Article 24 — Contracts to be Assigned Article 25 — Partnering ................ EJCDC C•200 Suggested Instructions to Bidders for Construction Contracts Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page ............. I I 2 4 4 5 5 ..7 ..8 ..8 ..9 ..9 ..9 10 10 10 11 11 11 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA ARTICLE 1— DEFINED TERMS 1.01 Terms used in these Instructions to Bidders have the meanings indicated in the General Conditions and Supplementary Conditions. Additional terms used in these Instructions to Bidders have the meanings indicated below: A. Issuing Office — Issuing Office — The office from which the Bidding Documents are to be issued and where the bidding procedures are to be administered. Polarconsult Alaska, Inc. 907-258-2420 503 West 33rd Ave., Suite 310 Anchorage, Alaska 99503 ARTICLE 2 — COPIES OF BIDDING DOCUMENTS 2.01 Complete sets of the Bidding Documents in the number and for the deposit sum, if any, stated in the advertisement or invitation to bid may be obtained from the Issuing Office. The deposit will be refunded to each document holder of record who returns a complete set of Bidding Documents in good condition within 30 days after opening of Bids. 2.02 Complete sets of Bidding Documents shall be used in preparing Bids; neither Owner nor Engineer assumes any responsibility for errors or misinterpretations resulting from the use of incomplete sets of Bidding Documents. 2.03 Owner and Engineer, in making copies of Bidding Documents available on the above terms, do so only for the purpose of obtaining Bids for the Work and do not authorize or confer a license for any other use. ARTICLE 3 — QUALIFICATIONS OF BIDDERS 3.01 To demonstrate Bidder's qualifications to perform the Work, within 7 days of Owner's request? Bidder shall submit written evidence such as financial data, previous experience, present commitments, and such other data as may be called for below. A. A. Bidders must be licensed contractors in the State of Alaska and provide evidence of such authority and state contractor's license number. B. B. The skill and experience demonstrated by the Bidder in performing projects of a similar nature. C. C. A Bidder's representations concerning their qualifications will be construed a covenant under the Agreement. Should it appear that the Bidder has made a ma- terial misrepresentation, the Owner shall have the right to terminate the Agree- ment for the Contractor's breach, and the Owner may then pursue such remedies as provided in the Agreement Documents or as provided by state statute or as ap- Drooriate. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page I CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA 3.02 Bidder is advised to carefully review those portions of the Bid Form requiring Bidder's representations and certifications. ARTICLE 4 — EXAMINATION OF BIDDING DOCUMENTS, OTHER RELATED DATA, AND SITE 4.01 Subsiaface and Physical Conditions A. The Supplementary Conditions identify: 1. Those reports known to Owner of explorations and tests of subsurface conditions at or contiguous to the Site. 2. Those drawings known to Owner of physical conditions relating to existing surface or subsurface structures at the Site (except Underground Facilities). B. Copies of reports and drawings referenced in Paragraph 4.01.A will be made available by Owner to any Bidder on request. Those reports and drawings are not part of the Contract Documents, but the "technical data" contained therein upon which Bidder is entitled to rely as provided in Paragraph 4.02 of the General Conditions has been identi- fied and established in Paragraph 4.02 of the Supplementary Conditions. Bidder is re- sponsible for any interpretation or conclusion Bidder draws from any "technical data" or any other data, interpretations, opinions, or information contained in such reports or shown or indicated in such drawings. 4.02 Underground Facilities A. Information and data shown or indicated in the Bidding Documents with respect to ex- isting Underground Facilities at or contiguous to the Site is based upon information and data furnished to Owner and Engineer by owners of such Underground Facilities, in- cluding Owner, or others. 4.03 Hazardous Environmental Condition B. The Supplementary Conditions identify any reports and drawings known to Owner re- lating to a Hazardous Environmental Condition identified at the Site. C. Copies of reports and drawings referenced in Paragraph 4.03.A will be made available by Owner- to any Bidder on request. Those reports and drawings are not part of the Contract Documents, but the "technical data" contained therein upon which Bidder is entitled to rely as provided in Paragraph 4.06 of the General Conditions has been identi- fied and established in Paragraph 4.06 of the Supplementary Conditions. Bidder is re- sponsible for any interpretation or conclusion Bidder draws from any "technical data" or any other data, interpretations, opinions, or information contained in such reports or shown or indicated in such drawings. 4.04 Provisions concerning responsibilities for the adequacy of data furnished to prospective Bidders with respect to subsurface conditions, other physical conditions, and Under- EdCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright ® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 2 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA ground Facilities, and possible changes in the Bidding Documents due to differing or un- anticipated subsurface or physical conditions appear in Paragraphs 4.02, 4.03, and 4.04 of the General Conditions. Provisions concerning responsibilities for the adequacy of data furnished to prospective Bidders with respect to a Hazardous Environmental Condition at the Site, if any, and possible changes in the Contract Documents due to any Hazardous Environmental Condition uncovered or revealed at the Site which was not shown or indi- cated in the Drawings or Specifications or identified in the Contract Documents to be within the scope of the Work, appear in Paragraph 4.06 of the General Conditions. 4.05 On request, Owner will provide Bidder access to the Site to conduct such examinations, investigations, explorations, tests, and studies as Bidder deems necessary for submission of a Bid. Bidder shall fill all holes and clean up and restore the Site to its former condi- tion upon completion of such explorations, investigations, tests, and studies. Bidder shall comply with all applicable Laws and Regulations relative to excavation and utility lo- cates. 4.06 Reference is made to Article 7 of the Supplementary Conditions for the identification of the general nature of other work that is to be performed at the Site by Owner or others (such as utilities and other prime contractors) that relates to the Work contemplated by these Bidding Documents. On request, Owner will provide to each Bidder for examina- tion access to or copies of contract documents (other than portions thereof related to price) for such other work. 4.07 It is the responsibility of each Bidder before submitting a Bid to: A. examine and carefully study the Bidding Documents, and the other related data identi- fied in the Bidding Documents; B. visit the Site (or has chosen not to perform a site visit and is submitting the Bid at the Bidder's own risk) and become familiar with and satisfy Bidder as to the general, local, and Site conditions that may affect cost, progress, and performance of the Work; C. become familiar with and satisfy Bidder as to all federal, state, and local Laws and Regulations that may affect cost, progress, and performance of the Work; D. carefully study all: (1) reports of explorations and tests of subsurface conditions at or contiguous to the Site and all drawings of physical conditions relating to existing sur- face or subsurface structures at the Site (except Underground Facilities) that have been identified in Paragraph 4.02 of the Supplementary Conditions as containing reliable "technical data," and (2) reports and drawings of Hazardous Environmental Conditions, if any, at the Site that have been identified in the Paragraph 4.06 of the Supplementary Conditions as containing reliable "technical data"; E. consider the information known to Bidder; information commonly known to contrac- tors doing business in the locality of the Site; information and observations obtained from visits to the Site; the Bidding Documents; and the Site -related reports and draw- ings identified in the Bidding Documents, with respect to the effect of such informa- tion, observations, and documents on (1) the cost, progress, and performance of the EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA Work; (2) the means, methods, techniques, sequences, and procedures of construction to be employed by Bidder, including applying any specific means, methods, techniques, sequences, and procedures of construction expressly required by the Bidding Docu- ments; and (3) Bidder's safety precautions and programs; F. agree at the time of submitting its Bid that no further examinations, investigations, ex- plorations, tests, studies, or data are necessary for the determination of its Bid for per- formance of the Work at the price(s) bid and within the times required, and in accor- dance with the other terms and conditions of the Bidding Documents; G. become aware of the general nature of the work to be performed by Owner and others at the Site that relates to the Work as indicated in the Bidding Documents; H. promptly give Engineer written notice of all conflicts, errors, ambiguities, or discrepan- cies that Bidder discovers in the Bidding Documents and confirm that the written reso- lution thereof by Engineer is acceptable to Bidder; and I. determine that the Bidding Documents are generally sufficient to indicate and convey understanding of all terms and conditions for the performance of the Work. 4.08 The submission of a Bid will constitute an incontrovertible representation by Bidder that Bidder has complied with every requirement of this Article 4, that without exception the Bid is premised upon performing and furnishing the Work required by the Bidding Documents and applying any specific means, methods, techniques, sequences, and proce- dures of construction that may be shown or indicated or expressly required by the Bid- ding Documents, that Bidder has given Engineer written notice of all conflicts, errors, ambiguities, and discrepancies that Bidder has discovered in the Bidding Documents and the written resolutions thereof by Engineer are acceptable to Bidder, and that the Bidding Documents are generally sufficient to indicate and convey understanding of all terms and conditions for performing and furnishing the Work. ARTICLE 5 — PRE -BID CONFERENCE 5.01 A pre -Bid conference will be held at < < [a.m.][p.m.] local time on - at Representatives of Owner and Engineer will be present to discuss the Project. Bidders are encouraged to attend and participate in the conference. Engineer will transmit to all prospective Bidders of record such Addenda as Engineer considers necessary in response to questions arising at the conference. Oral statements may not be relied upon and will not be binding or legally effective. ARTICLE 6 — SITE AND OTHER AREAS 6.01 The Site is identified in the Bidding Documents. Easements for permanent structures or permanent changes in existing facilities are to be obtained and paid for by Owner unless otherwise provided in the Bidding Documents. All additional lands and access thereto required for temporary construction facilities, construction equipment, or storage of mate- rials and equipment to be incorporated in the Work are to be obtained and paid for by Contractor. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 4 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA ARTICLE 7 — INTERPRETATIONS AND ADDENDA 7.01 All questions about the meaning or intent of the Bidding Documents are to be submitted to Engineer in writing. Interpretations or clarifications considered necessary by Engineer in response to such questions will be issued by Addenda mailed or delivered to all parties recorded by Engineer as having received the Bidding Documents. Questions received less than ten days prior to the date for opening of Bids may not be answered. Only ques- tions answered by Addenda will be binding. Oral and other interpretations or clarifica- tions will be without legal effect. 7.02 Addenda may be issued to clarify, correct, or change the Bidding Documents as deemed advisable by Owner or Engineer prior- to Bid Opening. ARTICLE 8 — BID SECURITY 8.01 A Bid must be accompanied by Bid security made payable to Owner in an amount of _ percent of Bidder's maximum Bid price and in the form of a certified check, bank money order, or a Bid bond (on the form attached) issued by a surety meeting the re- quirements of Paragraphs 5.01 and 5.02 of the General Conditions. 8.02 The Bid security of the Successful Bidder will be retained until such Bidder has executed the Contract Documents, furnished the required contract security and met the other condi- tions of the Notice of Award, whereupon the Bid security will be returned. If the Suc- cessful Bidder fails to execute and deliver the Contract Documents and furnish the re- quired contract security within 15 days after the Notice of Award, Owner may consider Bidder to be in default, annul the Notice of Award, and the Bid security of that Bidder will be forfeited. Such forfeiture shall be Owner's exclusive remedy if Bidder defaults. The Bid security of other Bidders whom Owner believes to have a reasonable chance of receiving the award may be retained by Owner until the earlier of seven days after the Ef- fective Date of the Agreement or 61 days after the Bid opening, whereupon Bid security furnished by such Bidders will be returned. 8.03 Bid security of other Bidders whom Owner believes do not have a reasonable chance of receiving the award will be returned within seven days after the Bid opening. ARTICLE 9 — CONTRACT TIMES 9.01 The number of days within which, or the dates by which, [Milestones are to be achieved and] the Work is to be substantially completed and ready for final payment are set forth in the Agreement. ARTICLE 10 — LIQUIDATED DAMAGES 10.01 Provisions for liquidated damages, if any, are set forth in the Agreement. ARTICLE 11— SUBSTITUTE AND "OR -EQUAL" ITEMS EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 5 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA 11.01 The Contract, if awarded, will be on the basis of materials and equipment specified or described in the Bidding Documents without consideration of possible substitute or "or - equal" items. Whenever it is specified or described in the Bidding Documents that a sub- stitute or "or -equal" item of material or equipment may be furnished or used by Contrac- tor if acceptable to Engineer, application for such acceptance will not be considered by Engineer until after the Effective Date of the Agreement. ARTICLE 12 — SUBCONTRACTORS, SUPPLIERS AND OTHERS 12.01 If the Supplementary Conditions require the identity of certain Subcontractors, Suppliers, individuals, or entities to be submitted to Owner in advance of a specified date prior to the Effective Date of the Agreement, the apparent Successful Bidder, and any other Bid- der so requested, shall within five days after Bid opening, submit to Owner a list of all such Subcontractors, Suppliers, individuals, or entities proposed for those portions of the Work for which such identification is required. Such list shall be accompanied by an ex- perience statement with pertinent information regarding similar projects and other evi- dence of qualification for each such Subcontractor, Supplier, individual, or entity if re- quested by Owner. If Owner or Engineer, after due investigation, has reasonable objec- tion to any proposed Subcontractor, Supplier, individual, or entity, Owner may, before the Notice of Award is given, request apparent Successful Bidder to submit a substitute, in which case apparent Successful Bidder- shall submit an acceptable substitute, Bidder's Bid price will be increased (or decreased) by the difference in cost occasioned by such substitution, and Owner may consider such price adjustment in evaluating Bids and mak- ing the Contract award. 12.02 If apparent Successful Bidder declines to make any such substitution, Owner may award the Contract to the next lowest Bidder that proposes to use acceptable Subcontractors, Suppliers, individuals, or entities. Declining to make requested substitutions will not constitute grounds for forfeiture of the Bid security of any Bidder. Any Subcontractor, Supplier, individual, or entity so listed and against which Owner or Engineer makes no written objection prior to the giving of the Notice of Award will be deemed acceptable to Owner and Engineer- subject to revocation of such acceptance after the Effective Date of the Agreement as provided in Paragraph 6.06 of the General Conditions. 12.03 Contractor shall not be required to employ any Subcontractor, Supplier, individual, or entity against whom Contractor has reasonable objection. ARTICLE 13 — PREPARATION OF BID 13.01 The Bid Form is included with the Bidding Documents. Additional copies may be ob- tained from Engineer. 13.02 All blanks on the Bid Form shall be completed in ink and the Bid Form signed in ink. Erasures or alterations shall be initialed in ink by the person signing the Bid Form. A Bid price shall be indicated for each Bid item listed therein. In the case of optional alterna- tives the words "No Bid," "No Change," or "Not Applicable" may be entered. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA 13.03 A Bid by a corporation shall be executed in the corporate name by the president or a vice- president or other corporate officer accompanied by evidence of authority to sign. The corporate seal shall be affixed and attested by the secretary or an assistant secretary. The corporate address and state of incorporation shall be shown. 13.04 A Bid by a partnership shall be executed in the partnership name and signed by a partner (whose title must appear under the signature), accompanied by evidence of authority to sign. The official address of the partnership shall be shown. 13.05 A Bid by a limited liability company shall be executed in the name of the firm by a mem- ber and accompanied by evidence of authority to sign. The state of formation of the firm and the official address of the firm shall be shown. 13.06 A Bid by an individual shall show the Bidder's name and official address. 13.07 A Bid by a joint venture shall be executed by each joint venture in the manner indicated on the Bid Form. The official address of the joint venture shall be shown. 13.08 All names shall be printed in ink below the signatures. 13.09 The Bid shall contain an acknowledgment of receipt of all Addenda, the numbers of which shall be filled in on the Bid Form. 13.10 Postal and e-mail addresses and telephone number for communications regarding the Bid shall be shown. 13.11 The Bid shall contain evidence of Bidder's authority and qualification to do business in the state where the Project is located, or Bidder- shall covenant in writing to obtain such authority and qualification prior to award of the Contract and attach such covenant to the Bid. Bidder's state contractor license number, if any, shall also be shown on the Bid Form. ARTICLE 14 — BASIS OF BID; COMPARISON OF BIDS 14.01 Stipulated Price (Lump Sum) A. Bidders shall submit a Bid on a Stipulated Price (lump sum) basis for the base Bid and include a separate price for each alternate described in the Bidding Documents as pro- vided for in the Bid Form. The price for each alternate will be the amount added to or deleted from the base Bid if Owner selects the alternate. In the comparison of Bids, al- ternates will be applied in the same order as listed in the Bid form. 14.02 Unit D. iee A. Bidders shall submit a Bid efl, nit p a basis fqi- eaeh it,.m R f \i TRd l:,. ed in tl p, Rid • • se e-dulie. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA INSTRUCTIONS TO BIDDERS OWN �. MME ARTICLE 15 — SUBMITTAL OF BID 15.01 With each copy of the Bidding Documents, a Bidder is furnished one separate unbound copy of the Bid Form, and, if required, the Bid Bond Form. The unbound copy of the Bid Form is to be completed and submitted with the Bid security and the following docu- ments: 15.02 A Bid shall be submitted no later than the date and time prescribed and at the place indi- cated in the advertisement or invitation to bid and shall be enclosed in a plainly marked package with the Project title (and, if applicable, the designated portion of the Project for which the Bid is submitted), the name and address of Bidder, and shall be accompanied by the Bid security and other required documents. If a Bid is sent by mail or other deliv- ery system, the sealed envelope containing the Bid shall be enclosed in a separate pack- age plainly marked on the outside with the notation "BID ENCLOSED." A mailed Bid shall be addressed to Engineer at Polarconsult Alaska, Inc. 1503 W. 337-d Avenue, Suite 310, Anchorage, Alaska 99503. ARTICLE 16 — MODIFICATION AND WITHDRAWAL OF BID 16.01 A Bid may be modified or withdrawn by an appropriate document duly executed in the same manner that a Bid must be executed and delivered to the place where Bids are to be submitted prior to the date and time for the opening of Bids. No telephonic (phone, fax, email, or other electronic communications) will be accepted. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 8 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA 16.02 If within 24 hours after Bids are opened any Bidder files a duly signed written notice with Owner and promptly thereafter demonstrates to the reasonable satisfaction of Owner that there was a material and substantial mistake in the preparation of its Bid, that Bidder may withdraw its Bid, and the Bid security will be returned. Thereafter, if the Work is rebid, that Bidder will be disqualified from further bidding on the Work. ARTICLE 17 — OPENING OF BIDS 17.01 Bids will be opened at the time and place indicated in the Advertisement or Invitation to Bid and, unless obviously non -responsive, read aloud publicly. An abstract of the amounts of the base Bids and major alternates, if any, will be made available to Bidders after the opening of Bids. ARTICLE 18 — BIDS TO REMAIN SUBJECT TO ACCEPTANCE 18.01 All Bids will remain subject to acceptance for the period of time stated in the Bid Form, but Owner may, in its sole discretion, release any Bid and return the Bid security prior to the end of this period. ARTICLE 19 — EVALUATION OF BIDS AND AWARD OF CONTRACT 19.01 Owner reserves the right to reject any or all Bids, including without limitation, noncon- forming, nonresponsive, unbalanced, or conditional Bids. Owner further reserves the right to reject the Bid of any Bidder whom it finds, after reasonable inquiry and evalua- tion, to not be responsible. Owner may also reject the Bid of any Bidder if Owner be- lieves that it would not be in the best interest of the Project to make an award to that Bid- der. Owner also reserves the right to waive all informalities not involving price, time, or changes in the Work and to negotiate contract terms with the Successful Bidder. 19.02 More than one Bid for the same Work from an individual or entity under the same or dif- ferent names will not be considered. Reasonable grounds for believing that any Bidder has an interest in more than one Bid for the Work may be cause for disqualification of that Bidder and the rejection of all Bids in which that Bidder has an interest. 19.03 In evaluating Bids, Owner will consider whether or not the Bids comply with the pre- scribed requirements, and such alternates, unit prices and other data, as may be requested in the Bid Form or prior to the Notice of Award. 19.04 In evaluating Bidders, Owner will consider the qualifications of Bidders and may con- sider the qualifications and experience of Subcontractors, Suppliers, and other individuals or entities proposed for those portions of the Work for which the identity of Subcontrac- tors, Suppliers, and other individuals or entities must be submitted as provided in the Supplementary Conditions. 19.05 Owner may conduct such investigations as Owner deems necessary to establish the re- sponsibility, qualifications, and financial ability of Bidders, proposed Subcontractors, Suppliers, individuals, or entities proposed for those portions of the Work in accordance with the Contract Documents. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 9 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA 19.06 If the Contract is to be awarded, Owner will award the Contract to the Bidder whose Bid is in the best interests of the Project. ARTICLE 20 — CONTRACT SECURITY AND INSURANCE 20.01 Article 5 of the General Conditions, as may be modified by the Supplementary Condi- tions, sets forth Owner's requirements as to performance and payment bonds and insur- ance. When the Successful Bidder delivers the executed Agreement to Owner, it shall be accompanied by such bonds. ARTICLE 21— SIGNING OF AGREEMENT 21.01 When Owner issues a Notice of Award to the Successful Bidder, it shall be accompanied by the required number of unsigned counterparts of the Agreement along with the other Contract Documents which are identified in the Agreement as attached thereto. Within 15 days thereafter, Successful Bidder shall sign and deliver the required number of coun- terparts of the Agreement and attached documents to Owner. Within ten days thereafter, Owner shall deliver one fully signed counterpart to Successful Bidder with a complete set of the Drawings with appropriate identification. EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 10 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA ARTICLE 23 — RETAINAGE 23.01 Provisions concerning Contractor's rights to deposit securities in lieu of retainage are set forth in the Agreement. ARTICLE 24 — CONTRACTS TO BE ASSIGNED 24.01 Owner as "Buyer" [has executed][will execute] a contract with as "Seller" for the procurement of goods and special services for The materials and equipment provided for in the procurement contract are to be furnished and delivered to the Site for installation by Contractor. The said procurement contract will be assigned by Owner to Contractor as set forth in the Agreement. Contractor will accept the assignment and assume responsibility for the "Seller," who will become a Supplier to Contractor. 24.02 Bidders may examine the contract documents used by the Owner for the procurement of goods and special services for at ._ ^ - M-0-1 M. - - - • z+�c� EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 11 EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 11 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 12 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY INSTRUCTIONS TO BIDDERS ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA EJCDC C-200 Suggested Instructions to Bidders for Construction Contracts Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 13 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA BID FORM TABLE OF CONTENTS Page Article1 — Bid Recipient................................................................................................................................... 1 Article 2 — Bidder's Acknowledgements.......................................................................................................... 1 Article 3 — Bidder's Representations................................................................................................................ 1 Article 4 — Bidder's Certification...................................................................................................................... 2 Article5 — Basis of Bid..................................................................................................................................... 3 Article6 — Time of Completion........................................................................................................................ 7 Article 7 — Attachments to This Bid................................................................................................................. 4 Article8 — Defined Terms................................................................................................................................. 4 Article9 — Bid Submittal................................................................................................................................... 4 E7CDC C-410 Suggested Bid Form for Construction Contracts Copyright m 2007 National Society of Professional Engineers for E7CDC. All rights reserved. Page xiv CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA ARTICLE 1— BID RECIPIENT 1.01 This Bid is submitted to: Atka Electric Utility c/o Polarconsult, Alaska Inc. 1503 W. 33`d Avenue, Suite 310 Anchorage, Alaska 99503 Tel (907) 258-2420 Fax (907) 258-2419 BID FORM f 1.02 The undersigned Bidder proposes and agrees, if this Bid is accepted, to enter into an Agreement with Owner in the form included in the Bidding Documents to perform all Work as specified or indicated in the Bidding Documents for the prices and within the times indicated in this Bid and in accordance with the other terms and conditions of the Bidding Documents. ARTICLE 2 — BIDDER'S ACKNOWLEDGEMENTS 2.01 Bidder accepts all of the terms and conditions of the Instructions to Bidders, including without limitation those dealing with the disposition of Bid security. This Bid will remain subject to acceptance for 60 days after the Bid opening, or for such longer period of time that Bidder may agree to in writing upon request of Owner. ARTICLE 3 — BIDDER'S REPRESENTATIONS 3.01 In submitting this Bid, Bidder represents that: A. Bidder has examined and carefully studied the Bidding Documents, other related data identified in the Bidding Documents, and the following Addenda, receipt of which is hereby acknowledged: Addendum No. Addendum Date B. Bidder has visited the Site (or has chosen not to perform a site visit and is submit- ting the Bid at the Bidder's own risk) and become familiar with and is satisfied as to the general, local, and Site conditions that may affect cost, progress, and performance of the Work. C. Bidder is familiar with and is satisfied as to all Laws and Regulations that may affect cost, progress, and performance of the Work. D. Bidder has carefully studied all: (1) reports of explorations and tests of subsurface con- ditions at or contiguous to the Site and all drawings of physical conditions relating to existing surface or subsurface structures at the Site (except Underground Facilities) that EJCDC C410 Suggested Bid Bond Form for Construction Contracts Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 1 of 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA 191010=95 have been identified in SC-4.02 as containing reliable "technical data," and (2) reports and drawings of Hazardous Environmental Conditions, if any, at the Site that have been identified in SC-4.06 as containing reliable "technical data." E. Bidder has considered the information known to Bidder; information commonly known to contractors doing business in the locality of the Site; information and observations obtained from visits to the Site; the Bidding Documents; and the Site -related reports and drawings identified in the Bidding Documents, with respect to the effect of such in- formation, observations, and documents on (1) the cost, progress, and performance of the Work; (2) the means, methods, techniques, sequences, and procedures of construc- tion to be employed by Bidder, including applying the specific means, methods, tech- niques, sequences, and procedures of construction expressly required by the Bidding Documents; and (3) Bidder's safety precautions and programs. F. Based on the information and observations referred to in Paragraph 3.01.E above, Bid- der does not consider that further examinations, investigations, explorations, tests, stud- ies, or data are necessary for the determination of this Bid for performance of the Work at the price(s) bid and within the times required, and in accordance with the other terms and conditions of the Bidding Documents. G. Bidder is aware of the general nature of work to be performed by Owner and others at the Site that relates to the Work as indicated in the Bidding Documents. H. Bidder has given Engineer written notice of all conflicts, errors, ambiguities, or dis- crepancies that Bidder has discovered in the Bidding Documents, and the written reso- lution thereof by Engineer is acceptable to Bidder. I. The Bidding Documents are generally sufficient to indicate and convey understanding of all terms and conditions for the performance of the Work for which this Bid is sub- mitted. J. Bidder accepts that the Owner reserves the right to waive irregularities and to re- ject bids. ARTICLE 4 — BIDDER'S CERTIFICATION 4.01 Bidder certifies that: A. This Bid is genuine and not made in the interest of or on behalf of any undisclosed in- dividual or entity and is not submitted in conformity with any collusive agreement or rules of any group, association, organization, or corporation; B. Bidder has not directly or indirectly induced or solicited any other Bidder- to submit a false or sham Bid; C. Bidder has not solicited or induced any individual or entity to refrain from bidding; and EJCDC C-410 Suggested Bid Bond Form for Construction Contracts Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 2 of 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA BID FORM D. Bidder has not engaged in corrupt, fraudulent, collusive, or coercive practices in com- peting for the Contract. For the purposes of this Paragraph 4.0LD: 1. "corrupt practice" means the offering, giving, receiving, or soliciting of any thing of value likely to influence the action of a public official in the bidding process; 2. "fraudulent practice" means an intentional misrepresentation of facts made (a) to in- fluence the bidding process to the detriment of Owner, (b) to establish bid prices at artificial non-competitive levels, or (c) to deprive Owner of the benefits of free and open competition; 3. "collusive practice" means a scheme or arrangement between two or more Bidders, with or without the knowledge of Owner, a purpose of which is to establish bid prices at artificial, non-competitive levels; and 4. "coercive practice" means harming or threatening to harm, directly or indirectly, persons or their property to influence their participation in the bidding process or affect the execution of the Contract. ARTICLE 5 — BASIS OF BID 5.01 Bidder will complete the Work in accordance with the Contract Documents for the follow- ing price(s): STIPULATED PRICE (LUMP SUM) BID Mob/Demob $ System Construction $ Program Existing Switch ear Controls $ System Start-up and 1 day of Operational Training $ Stipulated Price (Lump Sum) Bid Price for Base Bid $ All specified cash allowances are included in the price(s) set forth above, and have been computed in accordance with Paragraph 11.02 of the General Conditions. ARTICLE 6 — TIME OF COMPLETION 6.01 Bidder agrees that the Work will be substantially complete and will be completed and ready for final payment in accordance with Paragraph 14.07 of the General Conditions on or before the dates or within the number of calendar days indicated in the Agreement. 6.02 Bidder- accepts the provisions of the Agreement as to liquidated damages. EJCDC C-410 Suggested Bid Bond Form for Construction Contracts Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 3 of 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY BID FORM ATKA,ALASKA ARTICLE 7 — ATTACHMENTS TO THIS BID 7.01 The following documents are submitted with and made a condition of this Bid: A. Required Bid security in the form of B. List of Proposed Subcontractors; C. List of Proposed Suppliers; D. List of Project References; E. Evidence of authority to do business in the state of the Project; or a written covenant to obtain such license within the time for acceptance of Bids; F. Contractor's License No.: G. Required Bidder Qualification Statement with Supporting Data; and ARTICLE 8 — DEFINED TERMS 8.01 The terms used in this Bid with initial capital letters have the meanings stated in the In- structions to Bidders, the General Conditions, and the Supplementary Conditions. ARTICLE 9 — BID SUBMITTAL 9.01 This Bid is submitted by: If Bidder is: An Individual Name (typed or printed): By: Doing business as: A Partnership Partnership Name: By: (Signature of general partner -- attach evidence of authority to sign) Name (typed or printed): (Individual's signature) EJCDC C410 Suggested Bid Bond Form for Construction Contracts Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 4 of 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA A Corporation Corporation Name: (SEAL) State of Incorporation: Type (General Business, Professional, Service, Limited Liability): (Signature -- attach evidence of authority to sign) Name (typed or printed): Title: (CORPORATE SEAL) Attest BID FORM Date of Qualification to do business in Atka, Alaska is A Joint Venture Name of Joint Venture: First Joint Venturer Name: (SEAL) I0 (Signature of first joint venture partner -- attach evidence of authority to sign) Name (typed or printed): Title: Second Joint Venturer Name: (SEAL) (Signature of second joint venture partner -- attach evidence of authority to sign) Name (typed or printed): Title: EJCDC C-410 Suggested Bid Bond Form for Construction Contracts Copyright @ 2007 National Society of professional Engineers for EJCDC. All rights reserved. Page 5 of 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA BID FORM (Each joint venturer must sign. The manner of signing for each individual, part- nership, and corporation that is a party to the joint venture should be in the man- ner indicated above.) Bidder's Business Address Phone No. E-mail SUBMITTED on 20 State Contractor License No. Fax No. EJCDC C410 Suggested Bid Bond Form for Construction Contracts Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 6 of 6 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA EJCDC C430 Bid Bond (Penal Sum Form) Prepared by the Engineers Joint Contract Documents Committee. "VOWTO imp CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA Any singular reference to Bidder, Surety, Owner or other party shall be considered plural where applicable. BIDDER (Name and Address): SURETY (Name and Address of Principal Place of Business): OWNER (Name and Address): M-M D Bid Due Date: Description (Project Name and Include Location): BOND Bond Number: Date (Not earlier than Bid due date): Penal sum (Words) i r (Figures) Surety and Bidder, intending to be legally bound hereby, subject to the terms set forth below, do each cause this Bid Bond to be duly executed by an authorized officer, agent, or representative. BIDDER Bidder's Name and Corporate By: Signature Attest: Print Name Title Signature SURETY (Seal) (Seal) Surety's Name and Corporate Seal By: Signature (Attach Power of Attorney) Print Name Title Attest: Signature Title Title Note: Above addresses are to be used for giving any required notice. Provide execution by any additional par- ties, such as joint venturers, if necessary. EJCDC C430 Bid Bond (Penal Sum Form) Prepared by the Engineers Joint Contract Documents Committee. Page I of CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY BID BOND ATKA,ALASKA 1. Bidder and Surety, jointly and severally, bind themselves, their heirs, executors, administra- tors, successors, and assigns to pay to Owner upon default of Bidder the penal sum set forth on the face of this Bond. Payment of the penal sum is the extent of Bidder's and Surety's liability. Recovery of such penal sum under the terms of this Bond shall be Owner's sole and exclusive remedy upon default of Bidder. 2. Default of Bidder shall occur upon the failure of Bidder to deliver within the time required by the Bidding Documents (or any extension thereof agreed to in writing by Owner) the executed Agreement required by the Bidding Documents and any performance and payment bonds re- quired by the Bidding Documents. 3. This obligation shall be null and void if: 4. Owner accepts Bidder's Bid and Bidder delivers within the time required by the Bidding Docu- ments (or any extension thereof agreed to in writing by Owner) the executed Agreement required by the Bidding Documents and any performance and payment bonds required by the Bidding Documents, or 5. All Bids are rejected by Owner, or 6. Owner fails to issue a Notice of Award to Bidder within the time specified in the Bidding Docu- ments (or any extension thereof agreed to in writing by Bidder and, if applicable, consented to by Surety when required by Paragraph 5 hereof). 7. Payment under this Bond will be due and payable upon default of Bidder and within 30 calendar days after receipt by Bidder and Surety of written notice of default from Owner, which notice will be given with reasonable promptness, identifying this Bond and the Project and including a statement of the amount due. 8. Surety waives notice of any and all defenses based on or arising out of any time extension to is- sue Notice of Award agreed to in writing by Owner and Bidder, provided that the total time for issuing Notice of Award including extensions shall not in the aggregate exceed 120 days from Bid due date without Surety's written consent. 9. No suit or action shall be commenced under this Bond prior to 30 calendar days after the notice of default required in Paragraph 4 above is received by Bidder and Surety and in no case later than one year after Bid due date. 10. Any suit or action under this Bond shall be commenced only in a court of competent jurisdiction located in the state in which the Project is located. 11. Notices required hereunder shall be in writing and sent to Bidder and Surety at their respective addresses shown on the face of this Bond. Such notices may be sent by personal delivery, com- mercial courier, or by United States Registered or Certified Mail, return receipt requested, post- age pre -paid, and shall be deemed to be effective upon receipt by the party concerned. 12. Surety shall cause to be attached to this Bond a current and effective Power of Attorney evidenc- ing the authority of the officer, agent, or representative who executed this Bond on behalf of Surety to execute, seal, and deliver such Bond and bind the Surety thereby. 13. This Bond is intended to conform to all applicable statutory requirements. Any applicable re- quirement of any applicable statute that has been omitted from this Bond shall be deemed to be included herein as if set forth at length. If any provision of this Bond conflicts with any applica- ble statute, then the provision of said statute shall govern and the remainder of this Bond that is not in conflict therewith shall continue in full force and effect. 14. The term "Bid" as used herein includes a Bid, offer, or proposal as applicable. EJCDC C430 Bid Bond (Penal Sum Form) Prepared by the Engineers Joint Contract Documents Committee. Paee 2 of 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY BID BOND ATKA,ALASKA Blank Pale EJCDC C-430 Bid Bond (Penal Sum Form) Prepared by the Engineers Joint Contract Documents Committee. Paee 3 of 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY NOTICE OF AWARD ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA NOTICE OF AWARD EJCDC C-510 Notice of Award Prepared by the Engineers Joint Contract Documents Committee and endorsed by the Construction Specifications Institute. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY NOTICE OF AWARD ATKA,ALASKA Notice of Award Date: Project: Chuniisax Hydroelectric Dispactable Energy Owner: Atka Electric Utility Owner's Contract No.: Contract: Engineer's Project No.: Bidder: Bidder's Address: You are notified that your Bid dated for the above Contract has been considered. You are the Successful Bidder and are awarded a Contract for Chuniisax Hydroelectric Dispactable Energy including: Base Bid (and Additive Alternates if included). The Contract Price of your Contract is Dollars ($) copies of the proposed Contract Documents (except Drawings) accompany this Notice of Award. You must comply with the following conditions precedent within [15] days of the date you receive this Notice of Award. 1. Deliver to the Owner r] fully executed counterparts of the Contract Documents. 2. Deliver with the executed Contract Documents the Contract security [Bonds] as specified in the Instructions to Bidders (Article 20), General Conditions (Paragraph 5.01), and Supplementary Conditions (Paragraph SC-5.01). 3. Other conditions precedent: Failure to comply with these conditions within the time specified will entitle Owner to consider you in default, annul this Notice of Award, and declare your Bid security forfeited. Within ten days after you comply with the above conditions, Owner will return to you one fully executed counterpart of the Contract Documents. Owner Authorized Signature Title Copy to Engineer EJCDC C•510 Notice of Award Prepared by the Engineers Joint Contract Documents Committee and endorsed by the Construction Specifications Institute. Page 1 of f CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA CONTRACT FOR A STIPULATED PRICE r EJCDC C•520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA CONTRACT FOR STIPULATED PRICE (LUMP SUM) THIS AGREEMENT is by and between Atka Electric Utility (AEU) ("Owner") and ("Contractor"). Owner and Contractor hereby agree as follows: ARTICLE 1— WORK 1.01 Contractor shall complete all Work as specified or indicated in the Contract Documents. The Work is generally described as follows: The Chuniisax Hydroelectric Dispatchable Energy Project consists of the construction of electrical heating systems in 6 existing buildings, connection to existing hydronic heating systems, installation of duplex electric meter bases and controls, and programming existing hydroelectric power plant controls to operate dispatchable energy system and training electrical utility personnel in operation of the system. The work for this project may include, but not limited to, furnishing all labor, materials, tools, and equipment and performing all operations in connection with the new dispatchable energy system as shown in the construction documents. ARTICLE 2 — THE PROJECT 2.01 The Project for which the Work under the Contract Documents may be the whole or only a part is generally described as follows: The same as described under 1.01. ARTICLE 3 — ENGINEER 3.01 The Project has been designed by Polarconsult Alaska, Inc. (Engineer), which is to act as Owner's representative, assume all duties and responsibilities, and have the rights and authority assigned to Engineer in the Contract Documents in connection with the comple- tion of the Work in accordance with the Contract Documents. ARTICLE 4 — CONTRACT TIMES 4.01 Time of the Essence A. All time limits for Milestones, if any, Substantial Completion, and completion and readiness for final payment as stated in the Contract Documents are of the essence of the Contract. EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 1 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA 4.02 Dates for Substantial Completion and Final Payment A. The Work will be substantially completed on or before -, and completed and ready for final payment in accordance with Paragraph 14.07 of the General Conditions on or before 4.02 Liquidated Damages A. Contractor and Owner recognize that time is of the essence as stated in Paragraph 4.01 above and that Owner will suffer financial loss if the Work is not completed within the times specified in Paragraph 4.02 above, plus any extensions thereof allowed in accor- dance with Article 12 of the General Conditions. The parties also recognize the delays, expense, and difficulties involved in proving in a legal or arbitration proceeding the ac- tual loss suffered by Owner if the Work is not completed on time. Accordingly, instead of requiring any such proof, Owner and Contractor agree that as liquidated damages for delay (but not as a penalty), Contractor shall pay Owner $<` for each day that ex- pires after the time specified in Paragraph 4.02 above for Substantial Completion until the Work is substantially complete. After Substantial Completion, if Contractor shall neglect, refuse, or fail to complete the remaining Work within the Contract Time or any proper extension thereof granted by Owner, Contractor shall pay Owner $ for each day that expires after the time specified in Paragraph 4.02 above for completion and readiness for final payment until the Work is completed and ready for final pay- ment. ARTICLE 5 — CONTRACT PRICE 5.01 Owner shall pay Contractor for completion of the Work in accordance with the Contract Documents an amount in current funds equal to the sum of the amounts determined pur- suant to Paragraphs 5.01.A, 5.01.13, and 5.0l.0 below: A. For all Work, a Stipulated Price (lump sum) of: $ B. All specific cash allowances are included in the above price in accordance with Paragraph 11.02 of the General Conditions. ARTICLE 6 — PAYMENT PROCEDURES 6.01 Submittal and Processing of Payments A. Contractor shall submit Applications for Payment in accordance with Article 14 of the General Conditions. Applications for Payment will be processed by Engineer as pro- vided in the General Conditions. 6.02 Progress Payments; Retainage A. Owner shall make progress payments on account of the Contract Price on the basis of Contractor's Applications for Payment on or about the loth day of each month during EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright D 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 2 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA performance of the Work as provided in Paragraph 6.02.A.I below. All such payments will be measured by the schedule of values established as provided in Paragraph 2.07.A of the General Conditions (and in the case of Unit Price Work based on the number of units completed) or, in the event there is no schedule of values, as provided in the Gen- eral Requirements. 1. Prior to Substantial Completion, progress payments will be made in an amount equal to the percentage indicated below but, in each case, less the aggregate of payments previously made and less such amounts as Engineer may determine or Owner may withhold, including but not limited to liquidated damages, in accor- dance with Paragraph 14.02 of the General Conditions. a. 90% percent of Work completed (with the balance being retainage). If the Work has been 50 percent completed as determined by Engineer, and if the character and progress of the Work have been satisfactory to Owner and Engi- neer, then as long as the character and progress of the Work remain satisfactory to Owner and Engineer, there will be no additional retainage; and b. 90% percent of cost of materials and equipment not incorporated in the Work (with the balance being retainage). B. Upon Substantial Completion, Owner shall pay an amount sufficient to increase total payments to Contractor to 100% percent of the Work completed, less such amounts as Engineer shall determine in accordance with Paragraph 14.02.B.5 of the General Con- ditions and less 200% percent of Engineer's estimate of the value of Work to be com- pleted or corrected as shown on the tentative list of items to be completed or corrected attached to the certificate of Substantial Completion. 6.03 Final Payment A. Upon final completion and acceptance of the Work in accordance with Paragraph 14.07 of the General Conditions, Owner shall pay the remainder of the Contract Price as rec- ommended by Engineer as provided in said Paragraph 14.07. ARTICLE 7 — INTEREST 7.01 All moneys not paid when due as provided in Article 14 of the General Conditions shall bear interest at the rate of 9% percent per annum. ARTICLE 8 — CONTRACTOR'S REPRESENTATIONS 8.01 In order to induce Owner to enter into this Agreement, Contractor makes the following representations: A. Contractor has examined and carefully studied the Contract Documents and the other related data identified in the Bidding Documents. EJCDC C•520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 3 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA B. Contractor has visited (or has chosen not to perform a site visit and is submitting the Bid at the Bidder's own risk) the Site and become familiar with and is satisfied as to the general, local, and Site conditions that may affect cost, progress, and perform- ance of the Work. C. Contractor is familiar with and is satisfied as to all federal, state, and local Laws and Regulations that may affect cost, progress, and performance of the Work. D. Contractor has carefully studied all: (1) reports of explorations and tests of subsurface conditions at or contiguous to the Site and all drawings of physical conditions relating to existing surface or subsurface structures at the Site (except Underground Facilities), if any, that have been identified in Paragraph SC-4.02 of the Supplementary Conditions as containing reliable "technical data," and (2) reports and drawings of Hazardous Envi- ronmental Conditions, if any, at the Site that have been identified in Paragraph SC-4.06 of the Supplementary Conditions as containing reliable "technical data." E. Contractor has considered the information known to Contractor; information commonly known to contractors doing business in the locality of the Site; information and obser- vations obtained from visits to the Site; the Contract Documents; and the Site -related reports and drawings identified in the Contract Documents, with respect to the effect of such information, observations, and documents on (1) the cost, progress, and perform- ance of the Work; (2) the means, methods, techniques, sequences, and procedures of construction to be employed by Contractor, including any specific means, methods, techniques, sequences, and procedures of construction expressly required by the Con- tract Documents; and (3) Contractor's safety precautions and programs. F. Based on the information and observations referred to in Paragraph 8.01.E above, Con- tractor does not consider that further examinations, investigations, explorations, tests, studies, or data are necessary for the performance of the Work at the Contract Price, within the Contract Times, and in accordance with the other terms and conditions of the Contract Documents. G. Contractor is aware of the general nature of work to be performed by Owner and others at the Site that relates to the Work as indicated in the Contract Documents. H. Contractor has given Engineer written notice of all conflicts, errors, ambiguities, or dis- crepancies that Contractor has discovered in the Contract Documents, and the written resolution thereof by Engineer is acceptable to Contractor. I. The Contract Documents are generally sufficient to indicate and convey understanding of all terms and conditions for performance and furnishing of the Work. ARTICLE 9 — CONTRACT DOCUMENTS 9.01 Contents A. The Contract Documents consist of the following: EJCDC C520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 4 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA 1. This Agreement (pages 1 to 7, inclusive). 2. Performance bond (pages 1 to 3, inclusive). 3. Payment bond (pages 1 to 3, inclusive). 4. Other bends (Pages to inma). 5. General Conditions (pages 1 to 68, inclusive). 6. Supplementary Conditions (pages I to 3, inclusive). S. Drawings consisting of 14 sheets with each sheet bearing the following general ti- tle: Dispactable Energy Project AEA Project #7030001. 9. Addenda (numbers to , inclusive). 10. Exhibits to this Agreement (enumerated as follows): a. Contractor's Bid (pages to ,inclusive). b. Documentation submitted by Contractor prior to Notice of Award (pages to , inclusive). 11. The following which may be delivered or issued on or after- the Effective Date of the Agreement and are not attached hereto: a. Notice to Proceed. B. The documents listed in Paragraph 9.01.A are attached to this Agreement (except as expressly noted otherwise above). C. There are no Contract Documents other than those listed above in this Article 9. D. The Contract Documents may only be amended, modified, or supplemented as pro- vided in Paragraph 3.04 of the General Conditions. ARTICLE 10 — MISCELLANEOUS 10.01 Terns A. Terms used in this Agreement will have the meanings stated in the General Conditions and the Supplementary Conditions. EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 5 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA 10.02 Assignment of Contract A. No assignment by a party hereto of any rights under or interests in the Contract will be binding on another party hereto without the written consent of the party sought to be bound; and, specifically but without limitation, moneys that may become due and mon- eys that are due may not be assigned without such consent (except to the extent that the effect of this restriction may be limited by law), and unless specifically stated to the contrary in any written consent to an assignment, no assignment will release or dis- charge the assignor from any duty or responsibility under the Contract Documents. 10.03 Successors and Assigns A. Owner and Contractor each binds itself, its partners, successors, assigns, and legal rep- resentatives to the other party hereto, its partners, successors, assigns, and legal repre- sentatives in respect to all covenants, agreements, and obligations contained in the Con- tract Documents. 10.04 Severability A. Any provision or part of the Contract Documents held to be void or unenforceable un- der any Law or Regulation shall be deemed stricken, and all remaining provisions shall continue to be valid and binding upon Owner and Contractor, who agree that the Con- tract Documents shall be reformed to replace such stricken provision or part thereof with a valid and enforceable provision that comes as close as possible to expressing the intention of the stricken provision. 10.05 Contractor's Certifications A. Contractor certifies that it has not engaged in corrupt, fraudulent, collusive, or coercive practices in competing for or in executing the Contract. For the purposes of this Para- graph 10.05: 1. "corrupt practice" means the offering, giving, receiving, or soliciting of any thing of value likely to influence the action of a public official in the bidding process or in the Contract execution; 2. "fraudulent practice" means an intentional misrepresentation of facts made (a) to in- fluence the bidding process or the execution of the Contract to the detriment of Owner, (b) to establish Bid or Contract prices at artificial non-competitive levels, or (c) to deprive Owner of the benefits of free and open competition; 3. "collusive practice" means a scheme or arrangement between two or more Bidders, with or without the knowledge of Owner, a purpose of which is to establish Bid prices at artificial, non-competitive levels; and EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright 02007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 6 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY CONTRACT FOR A STIPULATED PRICE ATKA,ALASKA 4. "coercive practice" means harming or threatening to harm, directly or indirectly, persons or their property to influence their participation in the bidding process or affect the execution of the Contract. IN WITNESS WHEREOF, Owner and Contractor have signed this Agreement. Counterparts have been delivered to Owner and Contractor. All portions of the Contract Documents have been signed or have been identified by Owner and Contractor or on their behalf. This Agreement will be effective on (which is the Effective Date of the Agreement). OWNER: Atka Electric Utilit By: Title: Attest: Title: Address for giving notices: CONTRACTOR By: Title: (If Contractor is a corporation, a partnership, or a joint venture, attach evidence of authority to sign.) Attest: Title: Address for giving notices: License No.: (If Owner is a corporation, attach evidence of authority to sign. If Owner is a public body, attach evidence of authority to sign and resolution or other Agent for service of process: documents authorizing execution of this Agreement.) EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 7 of 7 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA NOTICE TO PROCEED CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKAALASKA NOTICE TO PROCEED EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA Notice to Proceec r Y k 1.: � 1�=°°- ate: Project: Chuniisax Hydroelectric Dispactable Energy Project Owner: Atka Electric Utility Owner's Contract No.: Contract: Engineer's Project No.: Contractor: Contractor's Address: NOTICE TO PROCEED You are notified that the Contract Times under the above Contract will commence to run on On or before that date, you are to start performing your obligations under the Contract Documents. In accordance with Article 4 of the Agreement, the date of Substantial Completion is and the date of readiness for final payment is [(or) the number of days to achieve Substantial Completion is and the number of days to achieve readiness for final payment is ]. Before you may start any Work at the Site, Paragraph 2.013 of the General Conditions provides that you and Owner must each deliver to the other (with copies to Engineer and other identified additional insureds and loss payees) certificates of insurance which each is required to purchase and maintain in accordance with the Contract Documents. Also, before you may start any Work at the Site, you must: [add other requirements]. Owner Given by: Authorized Signature Title Date Copy to Engineer EJCDC C•520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 1 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA PERFORMANCE BOND CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA PERFORMANCE BOND EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY PERFORMANCE BOND ATKA,ALASKA PERFORMANCE BOND Any singular reference to Contractor, Surety, Owner, or other party shall be considered plural where applicable. CONTRACTOR (Name and Address): OWNER (Name and Address): CONTRACT Effective Date of Agreement: Amount: Description (Name and Location): BOND Bond Number: Date (Not earlier than Effective Date of Agreement): Amount: Modifications to this Bond Form: SURETY (Name, and Address of Principal Place of Business): t d. yAk tY h try, cr,.l� Surety and Contractor, intending to be legally bound hereby, subject to the terms set forth below, do each cause this Performance Bond to be duly executed by an authorized officer, agent, or representative. CONTRACTOR AS PRINCIPAL (Seal) Contractor's Name and Corporate Seal By: Signature Print Name Title Attest: Signature Title SURETY Surety's Name and Corporate Seal By: Signature (Attach Power of Attorney) Print Name Title Attest: Signature Title EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright @ 2007 National Society of Professional Engineers for FJCDC. All rights reserved. Page t (Seal) CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY PERFORMANCE BOND ATKA,ALASKA Note: Provide execution by additional parties, such as joint venturers, if necessary. Contractor and Surety, jointly and severally, bind themselves, their heirs, executors, administrators, successors, and assigns to Owner for the performance of the Contract, which is incorporated herein by reference. 1. If Contractor performs the Contract, Surety and Contractor have no obligation under this Bond, except to par- ticipate in conferences as provided in Paragraph 2.1. 2. If there is no Owner Default, Surety's obligation under this Bond shall arise after: 2.1 Owner has notified Contractor and Surety, at the addresses described in Paragraph 9 below, that Owner is considering declaring a Contractor Default and has requested and attempted to arrange a conference with Contractor and Surety to be held not later than 15 days after receipt of such notice to discuss methods of performing the Contract. If Owner, Contractor, and Surety agree, Contractor shall be allowed a reason- able time to perform the Contract, but such an agreement shall not waive Owner's right, if any, subse- quently to declare a Contractor Default; and 2.2 Owner has declared a Contractor Default and formally terminated Contractor's right to complete the Con- tract. Such Contractor Default shall not be declared earlier than 20 days after Contractor and Surety have received notice as provided in Paragraph 2.1; and 2.3 Owner has agreed to pay the Balance of the Contract Price to: 1. Surety in accordance with the terms of the Contract; or 2. Another contractor selected pursuant to Paragraph 3.3 to perform the Contract. 3. When Owner has satisfied the conditions of Paragraph 2, Surety shall promptly, and at Surety's expense, take one of the following actions: 3.1 Arrange for Contractor, with consent of Owner, to perform and complete the Contract; or 3.2 Undertake to perform and complete the Contract itself, through its agents or through independent contrac- tors; or 3.3 Obtain bids or negotiated proposals from qualified contractors acceptable to Owner for a contract for per- formance and completion of the Contract, arrange for a contract to be prepared for execution by Owner and contractor selected with Owner's concurrence, to be secured with performance and payment bonds executed by a qualified surety equivalent to the bonds issued on the Contract, and pay to Owner the amount of damages as described in Paragraph 5 in excess of the Balance of the Contract Price incurred by Owner resulting from Contractor Default; or 3.4 Waive its right to perform and complete, arrange for completion, or obtain a new contractor, and with rea- sonable promptness under the circumstances: i. After investigation, determine the amount for which it may be liable to Owner and, as soon as practi- cable after the amount is determined, tender payment therefor to Owner; or 2. Deny liability in whole or in part and notify Owner citing reasons therefor. 4. If Surety does not proceed as provided in Paragraph 3 with reasonable promptness, Surety shall be deemed to be in default on this Bond 15 days after receipt of an additional written notice from Owner to Surety demanding that Surety perform its obligations under this Bond, and Owner shall be entitled to enforce any remedy available to Owner. If Surety proceeds as provided in Paragraph 3.4, and Owner refuses the payment tendered or Surety has denied liability, in whole or in part, without further notice Owner shall be entitled to enforce any remedy available to Owner. EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY PERFORMANCE BOND ATKA,ALASKA 5. After Owner has terminated Contractor's right to complete the Contract, and if Surety elects to act under Paragraph 3.1, 3.2, or 3.3 above, then the responsibilities of Surety to Owner shall not be greater than those of Contractor under the Contract, and the responsibilities of Owner to Surety shall not be greater than those of Owner under the Contract. To the limit of the amount of this Bond, but subject to commitment by Owner of the Balance of the Contract Price to mitigation of costs and damages on the Contract, Surety is obligated without du- plication for: 5.1 The responsibilities of Contractor for correction of defective Work and completion of the Contract; 5.2 Additional legal, design professional, and delay costs resulting from Contractor's Default, and resulting from the actions of or failure to act of Surety under Paragraph 3; and 5.3 Liquidated damages, or if no liquidated damages are specified in the Contract, actual damages caused by delayed performance or non-performance of Contractor. 6. Surety shall not be liable to Owner or others for obligations of Contractor that are unrelated to the Contract, and the Balance of the Contract Price shall not be reduced or set off on account of any such unrelated obligations. No right of action shall accrue on this Bond to any person or entity other than Owner or its heirs, executors, ad- ministrators, or successors. 7. Surety hereby waives notice of any change, including changes of time, to Contract or to related subcontracts, purchase orders, and other obligations. 8. Any proceeding, legal or equitable, under this Bond may be instituted in any court of competent jurisdiction in the location in which the Work or part of the Work is located, and shall be instituted within two years after Contractor Default or within two years after Contractor ceased working or within two years after Surety refuses or fails to perform its obligations under this Bond, whichever occurs first. If the provisions of this paragraph are void or prohibited by law, the minimum period of limitation available to sureties as a defense in the jurisdiction of the suit shall be applicable. 9. Notice to Surety, Owner, or Contractor shall be (nailed or delivered to the address shown on the signature page. 10. When this Bond has been furnished to comply with a statutory requirement in the location where the Contract was to be performed, any provision in this Bond conflicting with said statutory requirement shall be deemed de- leted herefrom and provisions conforming to such statutory requirement shall be deemed incorporated herein. The intent is that this Bond shall be construed as a statutory bond and not as a common law bond. 11. Definitions. 11.1 Balance of the Contract Price: The total amount payable by Owner to Contractor under the Contract after all proper adjustments have been made, including allowance to Contractor of any amounts received or to be received by Owner in settlement of insurance or other Claims for damages to which Contractor is entitled, reduced by all valid and proper payments made to or on behalf of Contractor under the Contract. 11.2 Contract: The agreement between Owner and Contractor identified on the signature page, including all Contract Documents and changes thereto. 11.3 Contractor Default: Failure of Contractor, which has neither been remedied nor waived, to perform or otherwise to comply with the terms of the Contract. 11.4 Owner Default: Failure of Owner, which has neither been remedied nor waived, to pay Contractor as required by the Contract or to perform and complete or otherwise comply with the other terms thereof. EJCDC C-520 Suggested Form of Agreement Between Owner and Contractor for Construction Contract (Stipulated Price) Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pape 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY PAYMENT BOND ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA PAYMENT BOND EJCDC C-615 Payment Bond Prepared by the Eneincers Joint Contract Documents Committee. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA PAYMENTBOND PAYMENT BOND Any singular reference to Contractor, Surety, Owner, or other party shall be considered plural where applicable. CONTRACTOR (Name and Address): OWNER (Name and Address): CONTRACT Effective Date of Agreement: Amount: Description (Name and Location): SURETY (Name, and Address of Principal Place of Business): Y 1t 1 'mot BOND Bond Number: Date (Not earlier than Effective Date of Agreement): Amount: Modifications to this Bond Form: Surety and Contractor, intending to be legally bound hereby, subject to the terms set forth below, do each cause this Payment Bond to be duly executed by an authorized officer, agent, or representative. CONTRACTOR AS PRINCIPAL (Seal) Contractor's Name and Corporate Seal By: Signature Print Name Title Attest: Signature Title SURETY Surety's Name and Corporate Seal al Signature (Attach Power of Attorney) Print Name Title Attest: Signature Title Note: Provide execution by additional parties, such as joint venturers, if necessa+3�. EJCDC C-615 Payment Bond Prepared by the Engineers Joint Contract Documents Committee. Pace 1 of 3 (Seal) CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY PAYMENT BOND ATKA,ALASKA Contractor and Surety, jointly and severally, bind themselves, their heirs, executors, administrators, suc- cessors, and assigns to Owner to pay for labor, materials, and equipment furnished by Claimants for use in the performance of the Contract, which is incorporated herein by reference. 1. With respect to Owner, this obligation shall be null and void if Contractor: 1.1 Promptly makes payment, directly or indirectly, for all sums due Claimants, and 1.2 Defends, indemnifies, and holds harmless Owner from all claims, demands, liens, or suits alleg ing non-payment by Contractor by any person or entity who furnished labor, materials, or equip- ment for use in the performance of the Contract, provided Owner has promptly notified Contrac- tor and Surety (at the addresses described in Paragraph 12) of any claims, demands, liens, or suits and tendered defense of such claims, demands, liens, or suits to Contractor and Surety, and pro- vided there is no Owner Default. 2. With respect to Claimants, this obligation shall be null and void if Contractor promptly makes pay- ment, directly or indirectly, for all sums due. 3. Surety shall have no obligation to Claimants under this Bond until: 3.1 Claimants who are employed by or have a direct contract with Contractor have given notice to Surety (at the address described in Paragraph 12) and sent a copy, or notice thereof, to Owner, stating that a claim is being made under this Bond and, with substantial accuracy, the amount of the claim. 3.2 Claimants who do not have a direct contract with Contractor: Have furnished written notice to Contractor and sent a copy, or notice thereof, to Owner, within 90 days after having last performed labor or last furnished materials or equipment in- cluded in the claim stating, with substantial accuracy, the amount of the claim and the name of the party to whom the materials or equipment were furnished or supplied, or for whom the labor was done or performed; and Have either received a rejection in whole or in part from Contractor, or not received within 30 days of furnishing the above notice any communication from Contractor by which Contractor had indicated the claim will be paid directly or indirectly; and Not having been paid within the above 30 days, have sent a written notice to Surety (at the address described in Paragraph 12) and sent a copy, or notice thereof, to Owner, stating that a claim is being made under this Bond and enclosing a copy of the previous written notice fur- nished to Contractor. 4. If a notice by a Claimant required by Paragraph 4 is provided by Owner to Contractor or to Surety, that is sufficient compliance. 5. When a Claimant has satisfied the conditions of Paragraph 4, the Surety shall promptly and at Surety's expense take the following actions: 5.1 Send an answer to that Claimant, with a copy to Owner, within 45 days after receipt of the claim, stating the amounts that are undisputed and the basis for challenging any amounts that are dis- puted. 5.2 Pay or arrange for payment of any undisputed amounts. 6. Surety's total obligation shall not exceed the amount of this Bond, and the amount of this Bond shall be credited for any payments made in good faith by Surety. 7. Amounts owed by Owner to Contractor under the Contract shall be used for the performance of the Contract and to satisfy claims, if any, under any performance bond. By Contractor furnishing and Owner EJCDC C-6I5 Payment Bond Prepared by the Engineers Joint Contract Documents Committee. Pace 2 of 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY PAYMENT BOND ATKA,ALASKA accepting this Bond, they agree that all funds earned by Contractor in the performance of the Contract are dedicated to satisfy obligations of Contractor and Surety under this Bond, subject to Owner's priority to use the funds for the completion of the Work. 8. Surety shall not be liable to Owner, Claimants, or others for obligations of Contractor that are unre- lated to the Contract. Owner shall not be liable for payment of any costs or expenses of any Claimant under this Bond, and shall have under this Bond no obligations to make payments to, give notices on be- half of, or otherwise have obligations to Claimants under this Bond. 9. Surety hereby waives notice of any change, including changes of time, to the Contract or to related subcontracts, purchase orders, and other obligations. 10. No suit or action shall be commenced by a Claimant under this Bond other than in a court of compe- tent jurisdiction in the location in which the Work or part of the Work is located or after the expiration of one year from the date (1) on which the Claimant gave the notice required by Paragraph 4.1 or Paragraph 4.2.3, or (2) on which the last labor or service was performed by anyone or the last materials or equipment were furnished by anyone under the Contract, whichever of (1) or (2) first occurs. If the provisions of this paragraph are void or prohibited by law, the minimum period of limitation available to sureties as a de- fense in the jurisdiction of the suit shall be applicable. 11. Notice to Surety, Owner, or Contractor shall be mailed or delivered to the addresses shown on the signature page. Actual receipt of notice by Surety, Owner, or Contractor, however accomplished, shall be sufficient compliance as of the date received at the address shown on the signature page. 12. When this Bond has been furnished to comply with a statutory requirement in the location where the Contract was to be performed, any provision in this Bond conflicting with said statutory requirement shall be deemed deleted herefrom and provisions conforming to such statutory requirement shall be deemed incorporated herein. The intent is that this Bond shall be construed as a statutory Bond and not as a common law bond. 13. Upon request of any person or entity appearing to be a potential beneficiary of this Bond, Contractor shall promptly furnish a copy of this Bond or shall permit a copy to be made. 14. Definitions 14.1 Claimant: An individual or entity having a direct contract with Contractor, or with a first -tier subcontractor of Contractor, to furnish labor, materials, or equipment for use in the performance of the Contract. The intent of this Bond shall be to include without limitation in the terms "labor, materials or equipment" that part of water, gas, power, light, heat, oil, gasoline, telephone service, or rental equipment used in the Contract, architectural and engineering services required for per- formance of the Work of Contractor and Contractor's subcontractors, and all other items for which a mechanic's lien may be asserted in the jurisdiction where the labor, materials, or equip- ment were furnished. 14.2 Contract: The agreement between Owner and Contractor identified on the signature page, in- cluding all Contract Documents and changes thereto. 14.3 Owner Default: Failure of Owner, which has neither been remedied nor waived, to pay Con- tractor as required by the Contract, or to perform and complete or otherwise comply with the other terns thereof. FOR INFORMATION ONLY — (Nmne, Address, and Telephone) Surety Agency or Broker: Owner's Representative (Engineer or other): FJCDC C-615 Payment Bond Prepared by the Engineers Joint Contract Documents Committee. Page 3 of 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA STANDARD CONDITIONS OF THE CONSTRUCTION CONTRACT 3 EJCDC C•700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT TABLE OF CONTENTS Page Article 1- Definitions and Terminology......................................................................................................... 1 1.01 Defined Terms.............................................................................................................................1 1.02 Terminology................................................................................................................................ 5 Article2 - Preliminary Matters........................................................................................................................ 7 2.01 Delivery of Bonds and Evidence of Insurance...........................................................................7 2.02 Copies of Documents..................................................................................................................7 2.03 Commencement of Contract Times; Notice to Proceed.............................................................7 2.04 Starting the Work........................................................................................................................7 2.05 Before Starting Construction .......................................................................................................7 2.06 Preconstruction Conference; Designation of Authorized Representatives................................8 2.07 Initial Acceptance of Schedules..................................................................................................8 Article 3 - Contract Documents: Intent, Amending, Reuse........................................................................... 9 3.01 Intent............................................................................................................................................ 9 3.02 Reference Standards....................................................................................................................9 3.03 Reporting and Resolving Discrepancies.....................................................................................9 3.04 Amending and Supplementing Contract Documents...............................................................10 3.05 Reuse of Documents..................................................................................................................11 3.06 Electronic Data.......................................................................................................................... I I A 'cle 4 - Availability of Lands; Subsurface and Physical Conditions; Hazardous Environmental C ditions; Reference Points............................................................. 11 4.01 Availability of Lands................................................................<..................'............................11 4.02 Subsurface and Physical Conditions ....................................... .....:;:........................................12 4.03 Differing Subsurface or Physical Conditions ........................ ................................................... 12 4.04 Underground Facilities.........................................................................:::.,..............................14 >; 4.05 Reference Points........................................................................................................................15 4.06 Hazardous Environmental Condition at Site ........................... ....... ....r.;................................... 15 Article 5 - Bonds and Insurance.................................................................................................................... 17 5.01 Performance, Payment, and Other Bonds ............................... 5.02 Licensed Sureties and Insurers............................................................: >: 5.03 Certificates of Insurance....................................................... . 5.04 Contractor's Insurance...................................................:::.........,, .......... 5.05 Owner's Liability Insurance.............................................................,.;.. 5.06 Property Insurance............................................................... r:::......... 5.07 Waiver of Rights............................................................:::::..........::: %..... 5.08 Receipt and Application of Insurance Proceeds ..... ......... 5.09 Acceptance of Bonds and Insurance; Option to Replace ..::: a 3'.... 5.10 Partial Utilization, Acknowledgment of Property Insurer ..................... Article 6 - Contractor's Responsibilities..................................................................... 6.01 Supervision and Superintendence 6.02 Labor; Working Hours ................. 24 ................................. 24 EJCDC C•700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page i CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 6.03 Services, Materials, and Equipment ........................ 6.04 Progress Schedule .................................................... 6.05 Substitutes and "Or -Equals" ................................... 6.06 Concerning Subcontractors, Suppliers, and Others 6.07 Patent Fees and Royalties ............................ 6.08 Permits......................................................... 6.09 Laws and Regulations ................................. 6.10 Taxes............................................................ 6.11 Use of Site and Other Areas ........................ 6.12 Record Documents ...................................... 6.13 Safety and Protection ................................... 6.14 Safety Representative .................................. 6.15 Hazard Communication Programs .............. 6.16 Emergencies ................................................. 6.17 Shop Drawings and Samples ....................... 6.18 Continuing the Work ................................... 6.19 Contractor's General Warranty and Guaran 6.20 Indemnification ............................................ 6.21 Delegation of Professional Design Service: Article 7 - Other Work at the Site ................................... 7.01 Related Work at Site ................................. 7.02 Coordination ............................................. 7.03 Legal Relationships .................................. Article 8 - Owner's Responsibilities ............................ 8.01 Communications to Contractor .................................. 8.02 Replacement of Engineer ........................................... 8.03 Furnish Data............................................................... 8.04 Pay When Due............................................................ 8.05 Lands and Easements; Reports and Tests .................. 8.06 Insurance..................................................................... 8.07 Change Orders............................................................ 8.08 Inspections, Tests, and Approvals ............................. 8.09 Limitations on Owner's Responsibilities ................... 8.10 Undisclosed Hazardous Environmental Condition ... 8.11 Evidence of Financial Arrangements ......................... 8.12 Compliance with Safety Program .............................. Article 9 - Engineer's Status During Construction ........................ 24 25 25 28 29 30 30 30 30 31 32 33 33 33 33 35 35 36 37 .38 ............................... 38 ................................. 38 ................................. 39 .................................. 39 9.01 Owner's Representative............................................................................................................41 9.02 Visits to Site...............................................................................................................................41 9.03 Project Representative...............................................................................................................41 9.04 Authorized Variations in Work.................................................................................................41 9.05 Rejecting Defective Work.........................................................................................................42 9.06 Shop Drawings, Change Orders and Payments........................................................................42 9.07 Determinations for Unit Price Work.........................................................................................42 EJCDC C-700 Standard General Conditions of the Construction Contract Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page ii CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 9.08 Decisions on Requirements of Contract Documents and Acceptability of Work...................42 9.09 Limitations on Engineer's Authority and Responsibilities......................................................43 9.10 Compliance with Safety Program.............................................................................................44 Article 10 - Changes in the Work; Claims..................................................................................................... 44 10.01 Authorized Changes in the Work..............................................................................................44 10.02 Unauthorized Changes in the Work..........................................................................................44 10.03 Execution of Change Orders.....................................................................................................44 10.04 Notification to Surety................................................................................................................45 10.05 Claims........................................................................................................................................45 Article 11 - Cost of the Work; Allowances; Unit Price Work...................................................................... 46 11.01 Cost of the Work.......................................................................................................................46 11.02 Allowances................................................................................................................................49 11.03 Unit Price Work.........................................................................................................................49 Article 12 - Change of Contract Price; Change of Contract Times.............................................................. 50 12.01 Change of Contract Price..........................................................................................................50 12.02 Change of Contract Times........................................................................................................51 12.03 Ilt=elays........................................................................................................................................51 Article 13 - Tests and Inspections; Correction, Removal or Acceptance of Defective Work ..................... 52 13.01 Notice of Defects.......................................................................................................................52 13.02 Access to Work..........................................................................................................................52 13.03 Tests and Inspections.................................................................................................................53 13.04 Uncovering Work......................................................................................................................53 13.05 Owner May Stop the Work.......................................................................................................54 13.06 Correction or Removal of Defective Work.............................................................................. 54 13.07 Correction Period.......................................................................................................................55 13.08 Acceptance of Defective Work.................................................................................................55 13.09 Owner May Correct Defective Work.......................................................................................56 Article 14 - Payments to Contractor and Completion................................................................................... 57 14.01 Schedule of Values....................................................................................................................57 14.02 Progress Payments.....................................................................................................................57 14.03 Contractor's Warranty of Title..................................................................................................60 14.04 Substantial Completion.............................................................................................................60 14.05 Partial Utilization.......................................................................................................................61 14.06 Final Inspection.........................................................................................................................61 14.07 Final Payment............................................................................................................................62 14.08 Final Completion Delayed........................................................................................................63 14.09 Waiver of Claims.......................................................................................................................63 Article 15 - Suspension of Work and Termination........................................................................................ 64 15.01 Owner May Suspend Work.......................................................................................................64 15.02 Owner May Terminate for Cause.............................................................................................64 15.03 Owner May Terminate For Convenience.................................................................................65 15.04 Contractor May Stop Work or Terminate.................................................................................66 Article 16 - Dispute Resolution...................................................................................................................... 66 EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace rrr CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 16.01 Methods and Procedures Article 17 — Miscellaneous ................ 17.01 Giving Notice .............. 17.02 Computation of Times. 17.03 Cumulative Remedies. 17.04 Survival of Obligations 17.05 Controlling Law........... 17.06 Headings ...................... 0 EJCDC C-700 Standard General Conditions of the Construction Contract Copyright ® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page iV 11 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT ARTICLE 1— DEFINITIONS AND TERMINOLOGY 1.01 Defined Teems A. Wherever used in the Bidding Requirements or Contract Documents and printed with initial capital letters, the terms listed below will have the meanings indicated which are applicable to both the singular and plural thereof. In addition to terms specifically de- fined, terms with initial capital letters in the Contract Documents include references to identified articles and paragraphs, and the titles of other documents or forms. Addenda —Written or graphic instruments issued prior to the opening of Bids which clarify, correct, or change the Bidding Requirements or the proposed Contract Documents. 2. Agreement —The written instrument which is evidence of the agreement between -. Owner and Contractor covering the Work. 3. Application for Payment —The form acceptable to Engineer which is to be used by J Contractor during the course of the Work in requesting progress or final payments and which is to be accompanied by such supporting documentation as is required by the Contract Documents. 4. Asbestos —Any material that contains more than one percent asbestos and is friable or is releasing asbestos fibers into the air above current action levels established by the United States Occupational Safety and Health Administration. 5. Bid —The offer or proposal of a Bidder submitted on the prescribed form setting forth the prices for the Work to be performed. 6. Bidder —The individual or entity who submits a Bid directly to Owner. 7. Bidding Documents —The Bidding Requirements and the proposed Contract Docu- ments (including all Addenda). IL-7 4 i 8. Bidding Reguirernents—The advertisement or invitation to bid, Instructions to Bid- ders, Bid security of acceptable form, if any, and the Bid Form with any supple- ments. 9. Change Order=A document recommended by Engineer which is signed by Con- tractor and Owner and authorizes an addition, deletion, or revision in the Work or an adjustment in the Contract Price or the Contract Times, issued on or after the Ef- fective Date of the Agreement. 10. Claim — A demand or assertion by Owner or Contractor seeking an adjustment of Contract Price or Contract Times, or both, or other relief with respect to the terms of the Contract. A demand for money or services by a third party is not a Claim. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace I of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 11. Contract —The entire and integrated written agreement between the Owner and Contractor concerning the Work. The Contract supersedes prior negotiations, rep- resentations, or agreements, whether written or oral. 12. Contract Documents —Those items so designated in the Agreement. Only printed or hard copies of the items listed in the Agreement are Contract Documents. Ap- proved Shop Drawings, other Contractor submittals, and the reports and drawings of subsurface and physical conditions are not Contract Documents. 13. Contract Price —The moneys payable by Owner to Contractor for completion of the Work in accordance with the Contract Documents as stated in the Agreement (sub- ject to the provisions of Paragraph 11.03 in the case of Unit Price Work). 14. Contract Times —The number of days or the dates stated in the Agreement to: (i) achieve Milestones, if any; (ii) achieve Substantial Completion; and (iii) complete the Work so that it is ready for final payment as evidenced by Engineer's written recommendation of final payment. 15. Contractor —The individual or entity with whom Owner has entered into the Agreement. 16. Cost of the Work —See Paragraph 11.01 for definition. 17. Drawings —That part of the Contract Documents prepared or approved by Engineer which graphically shows the scope, extent, and character of the Work to be per- formed by Contractor. Shop Drawings and other Contractor submittals are not Drawings as so defined. 18. Effective Date of the Agreement —The date indicated in the Agreement on which it becomes effective, but if no such date is indicated, it means the date on which the Agreement is signed and delivered by the last of the two parties to sign and deliver. 19. Engineer=The individual or entity named as such in the Agreement. 20. Field Order —A written order issued by Engineer which requires minor changes in the Work but which does not involve a change in the Contract Price or the Contract Times. 21. General Requirements —Sections of Division 1 of the Specifications. 22. Hazardous Environmental Condition —The presence at the Site of Asbestos, PCBs, Petroleum, Hazardous Waste, or Radioactive Material in such quantities or circum- stances that may present a substantial danger to persons or property exposed thereto. 23. Hazardous Waste —The term Hazardous Waste shall have the meaning provided in Section 1004 of the Solid Waste Disposal Act (42 USC Section 6903) as amended from time to time. EJCDC C•700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 2 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 24. Laws and Regulations; Laws or Regulations —Any and all applicable laws, rules, regulations, ordinances, codes, and orders of any and all governmental bodies, agencies, authorities, and courts having jurisdiction. 25. Liens —Charges, security interests, or encumbrances upon Project funds, real prop- erty, or personal property. 26. Milestone —A principal event specified in the Contract Documents relating to an in- termediate completion date or time prior to Substantial Completion of all the Work. 27. Notice ofAward—The written notice by Owner to the Successful Bidder stating that upon timely compliance by the Successful Bidder with the conditions precedent listed therein, Owner will sign and deliver the Agreement. 28. Notice to Proceed —A written notice given by Owner to Contractor fixing the date on which the Contract Times will commence to run and on which Contractor shall start to perform the Work under the Contract Documents. 29. Owner —The individual or entity with whom Contractor has entered into the Agreement and for whom the Work is to be performed. 30. PCBs —Polychlorinated biphenyls. 31. Petroleum —Petroleum, including crude oil or any fraction thereof which is liquid at standard conditions of temperature and pressure (60 degrees Fahrenheit and 14.7 pounds per square inch absolute), such as oil, petroleum, fuel oil, oil sludge, oil re- fuse, gasoline, kerosene, and oil mixed with other non -Hazardous Waste and crude oils. 32. Progress Schedule —A schedule, prepared and maintained by Contractor, describing the sequence and duration of the activities comprising the Contractor's plan to ac- complish the Work within the Contract Times. 33. Project —The total construction of which the Work to be performed under the Con- tract Documents may be the whole, or a part. 34. Project Manual —The bound documentary information prepared for bidding and constructing the Work. A listing of the contents of the Project Manual, which may be bound in one or more volumes, is contained in the table(s) of contents. 35. Radioactive Material —Source, special nuclear, or byproduct material as defined by the Atomic Energy Act of 1954 (42 USC Section 2011 et seq.) as amended from time to time. 36. Resident Project Representative —The authorized representative of Engineer who may be assigned to the Site or any part thereof. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 3 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 37. Samples —Physical examples of materials, equipment, or workmanship that are rep- resentative of some portion of the Work and which establish the standards by which such portion of the Work will be judged. 38. Schedule of Submittals —A schedule, prepared and maintained by Contractor, of re- quired submittals and the time requirements to support scheduled performance of related construction activities. 39. Schedule of Values —A schedule, prepared and maintained by Contractor, allocating portions of the Contract Price to various portions of the Work and used as the basis for reviewing Contractor's Applications for Payment. 40. Shop Drawings —All drawings, diagrams, illustrations, schedules, and other data or information which are specifically prepared or assembled by or for Contractor and submitted by Contractor to illustrate some portion of the Work. 41. Site —Lands or areas indicated in the Contract Documents as being furnished by Owner upon which the Work is to be performed, including rights -of -way and ease- ments for access thereto, and such other lands furnished by Owner which are desig- nated for the use of Contractor. 42. Specifications —That part of the Contract Documents consisting of written require- ments for materials, equipment, systems, standards and workmanship as applied to the Work, and certain administrative requirements and procedural matters applica- ble thereto. 43. Subcontractor —An individual or entity having a direct contract with Contractor or with any other Subcontractor for the performance of a part of the Work at the Site. 44. Substantial Completion —The time at which the Work (or a specified part thereof) has progressed to the point where, in the opinion of Engineer, the Work (or a speci- fied part thereof) is sufficiently complete, in accordance with the Contract Docu- ments, so that the Work (or a specified part thereof) can be utilized for the purposes for which it is intended. The terms "substantially complete" and "substantially completed" as applied to all or part of the Work refer to Substantial Completion thereof. 45. Successful Bidder —The Bidder submitting a responsive Bid to whom Owner makes an award. 46. Supplementary Conditions —That part of the Contract Documents which amends or supplements these General Conditions. 47. Supplier —A manufacturer, fabricator, supplier, distributor, materialman, or vendor having a direct contract with Contractor or with any Subcontractor to furnish mate- rials or equipment to be incorporated in the Work by Contractor or Subcontractor. EJCDC C•700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 4 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 48. Underground Facilities —All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any en- casements containing such facilities, including those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable televi- sion, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems. 49. Unit Price Work —Work to be paid for on the basis of unit prices. 50. Work —The entire construction or the various separately identifiable parts thereof required to be provided under the Contract Documents. Work includes and is the result of performing or providing all labor, services, and documentation necessary to produce such construction, and furnishing, installing, and incorporating all mate- rials and equipment into such construction, all as required by the Contract Docu- ments. 51. Work Change Directive —A written statement to Contractor issued on or after the Effective Date of the Agreement and signed by Owner and recommended by Engi- neer ordering an addition, deletion, or revision in the Work, or responding to differ- ing or unforeseen subsurface or physical conditions under which the Work is to be performed or to emergencies. A Work Change Directive will not change the Con- tract Price or the Contract Times but is evidence that the parties expect that the change ordered or documented by a Work Change Directive will be incorporated in a subsequently issued Change Order following negotiations by the parties as to its effect, if any, on the Contract Price or Contract Times. 1.02 Tenninology A. The words and terms discussed in Paragraph 1.02.13 through F are not defined but, when used in the Bidding Requirements or Contract Documents, have the indicated meaning. B. Intent of Certain Terms or Adjectives: 1. The Contract Documents include the terms "as allowed," "as approved," "as or- dered," "as directed" or terms of like effect or import to authorize an exercise of professional judgment by Engineer. In addition, the adjectives "reasonable," "suit- able," "acceptable," "proper," "satisfactory," or adjectives of like effect or import are used to describe an action or determination of Engineer- as to the Work. It is in- tended that such exercise of professional judgment, action, or determination will be solely to evaluate, in general, the Work for compliance with the information in the Contract Documents and with the design concept of the Project as a functioning whole as shown or indicated in the Contract Documents (unless there is a specific statement indicating otherwise). The use of any such term or adjective is not in- tended to and shall not be effective to assign to Engineer any duty or authority to supervise or direct the performance of the Work, or any duty or authority to under- EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 5 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT take responsibility contrary to the provisions of Paragraph 9.09 or any other provi- sion of the Contract Documents. C. Day: 1. The word "day" means a calendar day of 24 hours measured from midnight to the next midnight. D. Defective: 1. The word "defective," when modifying the word "Work," refers to Work that is un- satisfactory, faulty, or deficient in that it: a. does not conform to the Contract Documents; or b. does not meet the requirements of any applicable inspection, reference standard, test, or approval referred to in the Contract Documents; or c. has been damaged prior to Engineer's recommendation of final payment (unless responsibility for the protection thereof has been assumed by Owner at Substan- tial Completion in accordance with Paragraph 14.04 or 14.05). E. Furnish, Install, Pelforrn, Provide: The word "furnish," when used in connection with services, materials, or equip- ment, shall mean to supply and deliver said services, materials, or equipment to the Site (or some other specified location) ready for use or installation and in usable or operable condition. 2. The word "install," when used in connection with services, materials, or equipment, shall mean to put into use or place in final position said services, materials, or equipment complete and ready for intended use. 3. The words "perform" or "provide," when used in connection with services, materi- als, or equipment, shall mean to furnish and install said services, materials, or equipment complete and ready for intended use. 4. When "furnish," "install," "perform," or "provide" is not used in connection with services, materials, or equipment in a context clearly requiring an obligation of Contractor, "provide" is implied. F. Unless stated otherwise in the Contract Documents, words or phrases that have a well- known technical or constriction industry or trade meaning are used in the Contract Documents in accordance with such recognized meaning. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 6 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA ARTICLE 2 — PRELIMINARY MATTERS 2.01 Delivery of Bonds and Evidence of Insurance STANDARD CONDITIONS OF THE CONSTRUCTION CONTRACT A. When Contractor delivers the executed counterparts of the Agreement to Owner, Con- tractor shall also deliver to Owner such bonds as Contractor may be required to furnish. B. Evidence of Insurance: Before any Work at the Site is started, Contractor and Owner shall each deliver to the other, with copies to each additional insured identified in the Supplementary Conditions, certificates of insurance (and other evidence of insurance which either of them or any additional insured may reasonably request) which Contrac- tor and Owner respectively are required to purchase and maintain in accordance with Article 5. 2.02 Copies of Documents A. Owner shall furnish to Contractor up to ten printed or hard copies of the Drawings and Project Manual. Additional copies will be furnished upon request at the cost of repro- duction. 2.03 Commencement of Contract Tirnes; Notice to Proceed A. The Contract Times will commence to run on the thirtieth day after the Effective Date of the Agreement or, if a Notice to Proceed is given, on the day indicated in the Notice to Proceed. A Notice to Proceed may be given at any time within 30 days after the Ef- fective Date of the Agreement. In no event will the Contract Times commence to run later than the sixtieth day after the day of Bid opening or the thirtieth day after the Ef- fective Date of the Agreement, whichever date is earlier. 2.04 Starting the Work A. Contractor shall start to perform the Work on the date when the Contract Times com- mence to run. No Work shall be done at the Site prior to the date on which the Contract Times commence to run. 2.05 Before Starting Construction A. Preliminary Schedules: Within 10 days after the Effective Date of the Agreement (unless otherwise specified in the General Requirements), Contractor shall submit to Engineer for timely review: 1. a preliminary Progress Schedule indicating the times (numbers of days or dates) for starting and completing the various stages of the Work, including any Milestones specified in the Contract Documents; 2. a preliminary Schedule of Submittals; and EJCDC C-700 Standard General Conditions of the Construction Contract Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 7 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 3. a preliminary Schedule of Values for all of the Work which includes quantities and prices of items which when added together equal the Contract Price and subdivides the Work into component parts in sufficient detail to serve as the basis for progress payments during performance of the Work. Such prices will include an appropriate amount of overhead and profit applicable to each item of Work. 2.06 PreconstruCtion Conference; Designation of Authorized Representatives A. Before any Work at the Site is started, a conference attended by Owner, Contractor, Engineer, and others as appropriate will be held to establish a working understanding among the parties as to the Work and to discuss the schedules referred to in Paragraph 2.05.A, procedures for handling Shop Drawings and other submittals, processing Ap- plications for Payment, and maintaining required records. B. At this conference Owner and Contractor each shall designate, in writing, a specific in- dividual to act as its authorized representative with respect to the services and responsi- bilities under the Contract. Such individuals shall have the authority to transmit in- structions, receive information, render decisions relative to the Contract, and otherwise act on behalf of each respective party. 2.07 Initial Acceptance of Schedules A. At least 10 days before submission of the first Application for Payment a conference at- tended by Contractor, Engineer, and others as appropriate will be held to review for ac- ceptability to Engineer as provided below the schedules submitted in accordance with Paragraph 2.05.A. Contractor shall have an additional 10 days to make corrections and adjustments and to complete and resubmit the schedules. No progress payment shall be made to Contractor until acceptable schedules are submitted to Engineer. The Progress Schedule will be acceptable to Engineer if it provides an orderly pro- gression of the Work to completion within the Contract Times. Such acceptance will not impose on Engineer responsibility for the Progress Schedule, for sequenc- ing, scheduling, or progress of the Work, nor interfere with or relieve Contractor from Contractor's full responsibility therefor. 2. Contractor's Schedule of Submittals will be acceptable to Engineer if it provides a workable arrangement for reviewing and processing the required submittals. 3. Contractor's Schedule of Values will be acceptable to Engineer as to form and sub- stance if it provides a reasonable allocation of the Contract Price to component parts of the Work. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 8 of 68 CHUNHSAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT ARTICLE 3 — CONTRACT DOCUMENTS: INTENT, AMENDING, REUSE 3.01 Intent A. The Contract Documents are complementary; what is required by one is as binding as if required by all. B. It is the intent of the Contract Documents to describe a functionally complete project (or part thereof) to be constructed in accordance with the Contract Documents. Any la- bor, documentation, services, materials, or equipment that reasonably may be inferred from the Contract Documents or from prevailing custom or trade usage as being re- quired to produce the indicated result will be provided whether or not specifically called for, at no additional cost to Owner. C. Clarifications and interpretations of the Contract Documents shall be issued by Engi- neer as provided in Article 9. 3.02 Reference Standards A. Standards, Specifications, Codes, Laws, and Regulations 1. Reference to standards, specifications, manuals, or codes of any technical society, organization, or association, or to Laws or Regulations, whether such reference be specific or by implication, shall mean the standard, specification, manual, code, or Laws or Regulations in effect at the time of opening of Bids (or on the Effective Date of the Agreement if there were no Bids), except as may be otherwise specifi- cally stated in the Contract Documents. 2. No provision of any such standard, specification, manual, or code, or any instruc- tion of a Supplier, shall be effective to change the duties or responsibilities of Owner, Contractor, or Engineer, or any of their subcontractors, consultants, agents, or employees, from those set forth in the Contract Documents. No such provision or instruction shall be effective to assign to Owner, Engineer, or any of their offi- cers, directors, members, partners, employees, agents, consultants, or subcontrac- tors, any duty or authority to supervise or direct the performance of the Work or any duty or authority to undertake responsibility inconsistent with the provisions of the Contract Documents. 3.03 Reporting and Resolving Discrepancies A. Reporting Discrepancies: Contractor's Review of Contract Documents Before Starting Work: Before under- taking each part of the Work, Contractor shall carefully study and compare the Contract Documents and check and verify pertinent figures therein and all applica- ble field measurements. Contractor shall promptly report in writing to Engineer any conflict, error, ambiguity, or discrepancy which Contractor discovers, or has EJCDC C-700 Standard General Conditions of the Construction Contract Copyright® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 9 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA STANDARD CONDITIONS OF THE CONSTRUCTION CONTRACT actual knowledge of, and shall obtain a written interpretation or clarification from Engineer before proceeding with any Work affected thereby. 2. Contractor's Review of Contract Documents During Performance of Work: If, dur- ing the performance of the Work, Contractor discovers any conflict, error, ambigu- ity, or discrepancy within the Contract Documents, or between the Contract Docu- ments and (a) any applicable Law or Regulation , (b) any standard, specification, manual, or code, or (c) any instruction of any Supplier, then Contractor shall promptly report it to Engineer in writing. Contractor shall not proceed with the Work affected thereby (except in an emergency as required by Paragraph 6.16.A) until an amendment or supplement to the Contract Documents has been issued by one of the methods indicated in Paragraph 3.04. 3. Contractor shall not be liable to Owner or Engineer for failure to report any con- flict, error, ambiguity, or discrepancy in the Contract Documents unless Contractor had actual knowledge thereof. B. Resolving Discrepancies: Except as may be otherwise specifically stated in the Contract Documents, the pro- visions of the Contract Documents shall take precedence in resolving any conflict, error, ambiguity, or discrepancy between the provisions of the Contract Documents and: a. the provisions of any standard, specification, manual, or code, or the instruction of any Supplier (whether or not specifically incorporated by reference in the Contract Documents); or b. the provisions of any Laws or Regulations applicable to the performance of the Work (unless such an interpretation of the provisions of the Contract Docu- ments would result in violation of such Law or Regulation). 3.04 Anzending and Supplementing Contract Documents A. The Contract Documents may be amended to provide for additions, deletions, and revi- sions in the Work or to modify the terms and conditions thereof by either a Change Or- der or a Work Change Directive. B. The requirements of the Contract Documents may be supplemented, and minor varia- tions and deviations in the Work may be authorized, by one or more of the following ways: 1. A Field Order; 2. Engineer's approval of a Shop Drawing or Sample (subject to the provisions of Paragraph 6.17.D.3); or 3. Engineer's written interpretation or clarification. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 10 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 3.05 Reuse of Documents A. Contractor and any Subcontractor or Supplier shall not: have or acquire any title to or ownership rights in any of the Drawings, Specifica- tions, or other documents (or copies of any thereof) prepared by or bearing the seal of Engineer or its consultants, including electronic media editions; or 2. reuse any such Drawings, Specifications, other documents, or copies thereof on ex- tensions of the Project or any other project without written consent of Owner and Engineer and specific written verification or adaptation by Engineer. B. The prohibitions of this Paragraph 3.05 will survive final payment, or termination of the Contract. Nothing herein shall preclude Contractor from retaining copies of the Contract Documents for record purposes. 3.06 Electronic Data A. Unless otherwise stated in the Supplementary Conditions, the data furnished by Owner or Engineer to Contractor, or by Contractor to Owner or Engineer, that may be relied upon are limited to the printed copies (also known as hard copies). Files in electronic media format of text, data, graphics, or other types are furnished only for the conven- ience of the receiving party. Any conclusion or information obtained or derived from such electronic files will be at the user's sole risk. If there is a discrepancy between the electronic files and the hard copies, the hard copies govern. B. Because data stored in electronic media format can deteriorate or be modified inadver- tently or otherwise without authorization of the data's creator, the party receiving elec- tronic files agrees that it will perform acceptance tests or procedures within 60 days, af- ter which the receiving party shall be deemed to have accepted the data thus transferred. Any errors detected within the 60-day acceptance period will be corrected by the trans- ferring party. C. When transferring documents in electronic media format, the transferring party makes no representations as to long term compatibility, usability, or readability of documents resulting from the use of software application packages, operating systems, or computer hardware differing from those used by the data's creator. ARTICLE 4 — AVAILABILITY OF LANDS; SUBSURFACE AND PHYSICAL CONDITIONS; HAZARDOUS ENVIRONMENTAL CONDITIONS; REFERENCE POINTS 4.01 Availability of Lands A. Owner shall furnish the Site. Owner shall notify Contractor of any encumbrances or restrictions not of general application but specifically related to use of the Site with which Contractor must comply in performing the Work. Owner will obtain in a timely EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 1 I of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT manner and pay for easements for permanent structures or permanent changes in exist- ing facilities. If Contractor and Owner are unable to agree on entitlement to or on the amount or extent, if any, of any adjustment in the Contract Price or Contract Times, or both, as a result of any delay in Owner's furnishing the Site or a part thereof, Contrac- tor may make a Claim therefor as provided in Paragraph 10.05. B. Upon reasonable written request, Owner shall furnish Contractor with a current state- ment of record legal title and legal description of the lands upon which the Work is to be performed and Owner's interest therein as necessary for giving notice of or filing a mechanic's or construction lien against such lands in accordance with applicable Laws and Regulations. C. Contractor shall provide for all additional lands and access thereto that may be required for temporary construction facilities or storage of materials and equipment. 4.02 Subsufface and Physical Conditions A. Reports and Drawings: The Supplementary Conditions identify: 1. those reports known to Owner of explorations and tests of subsurface conditions at or contiguous to the Site; and 2. those drawings known to Owner of physical conditions relating to existing surface or subsurface structures at the Site (except Underground Facilities). B. Limited Reliance by Contractor on Technical Data Authorized: Contractor may rely upon the accuracy of the "technical data" contained in such reports and drawings, but such reports and drawings are not Contract Documents. Such "technical data" is identi- fied in the Supplementary Conditions. Except for such reliance on such "technical data," Contractor may not rely upon or make any claim against Owner or Engineer, or any of their officers, directors, members, partners, employees, agents, consultants, or subcontractors with respect to: 1. the completeness of such reports and drawings for Contractor's purposes, including, but not limited to, any aspects of the means, methods, techniques, sequences, and procedures of construction to be employed by Contractor, and safety precautions and programs incident thereto; or 2. other data, interpretations, opinions, and information contained in such reports or shown or indicated in such drawings; or 3. any Contractor interpretation of or conclusion drawn from any "technical data" or any such other data, interpretations, opinions, or information. 4.03 Differing Subsui face or Physical Conditions A. Notice: If Contractor believes that any subsurface or physical condition that is uncov- ered or revealed either: EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 12 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 1. is of such a nature as to establish that any "technical data" on which Contractor is entitled to rely as provided in Paragraph 4.02 is materially inaccurate; or 2. is of such a nature as to require a change in the Contract Documents; or 3. differs materially from that shown or indicated in the Contract Documents; or 4. is of an unusual nature, and differs materially from conditions ordinarily encoun- tered and generally recognized as inherent in work of the character provided for in the Contract Documents; 5. then Contractor shall, promptly after becoming aware thereof and before further disturbing the subsurface or physical conditions or performing any Work in connec- tion therewith (except in an emergency as required by Paragraph 6.16.A), notify Owner and Engineer in writing about such condition. Contractor shall not further disturb such condition or perform any Work in connection therewith (except as aforesaid) until receipt of written order to do so. B. Engineer's Review: After receipt of written notice as required by Paragraph 4.03.A, Engineer will promptly review the pertinent condition, determine the necessity of Owner's obtaining additional exploration or tests with respect thereto, and advise Owner in writing (with a copy to Contractor) of Engineer's findings and conclusions. C. Possible Price and Times Adjustments: 1. The Contract Price or the Contract Times, or both, will be equitably adjusted to the extent that the existence of such differing subsurface or physical condition causes an increase or decrease in Contractor's cost of, or time required for, performance of the Work; subject, however, to the following: a. such condition must meet any one or more of the categories described in Para- graph 4.03.A; and b. with respect to Work that is paid for on a unit price basis, any adjustment in Contract Price will be subject to the provisions of Paragraphs 9.07 and 11.03. 2. Contractor shall not be entitled to any adjustment in the Contract Price or Contract Times if: a. Contractor knew of the existence of such conditions at the time Contractor made a final commitment to Owner with respect to Contract Price and Contract Times by the submission of a Bid or becoming bound under a negotiated con- tract; or It. the existence of such condition could reasonably have been discovered or re- vealed as a result of any examination, investigation, exploration, test, or study of the Site and contiguous areas required by the Bidding Requirements or Con- EJCDC C-700 Standard General Conditions of the Construction Contract Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 13 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT tract Documents to be conducted by or for Contractor prior to Contractor's making such final commitment; or c. Contractor failed to give the written notice as required by Paragraph 4.03.A. 3. If Owner and Contractor are unable to agree on entitlement to or on the amount or extent, if any, of any adjustment in the Contract Price or Contract Times, or both, a Claim may be made therefor as provided in Paragraph 10.05. However, neither Owner or Engineer, or any of their officers, directors, members, partners, employ- ees, agents, consultants, or subcontractors shall be liable to Contractor for any claims, costs, losses, or damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitra- tion or other dispute resolution costs) sustained by Contractor on or in connection with any other project or anticipated project. 4.04 Underground Facilities A. Shown or Indicated: The information and data shown or indicated in the Contract Documents with respect to existing Underground Facilities at or contiguous to the Site is based on information and data furnished to Owner or Engineer by the owners of such Underground Facilities, including Owner, or by others. Unless it is otherwise expressly provided in the Supplementary Conditions: 1. Owner and Engineer shall not be responsible for the accuracy or completeness of any such information or data provided by others; and 2. the cost of all of the following will be included in the Contract Price, and Contrac- tor shall have full responsibility for: a. reviewing and checking all such information and data; b. locating all Underground Facilities shown or indicated in the Contract Docu- ments; c. coordination of the Work with the owners of such Underground Facilities, in- cluding Owner, during construction; and d. the safety and protection of all such Underground Facilities and repairing any damage thereto resulting from the Work. B. Not Shown or Indicated: 1. If an Underground Facility is uncovered or revealed at or contiguous to the Site which was not shown or indicated, or not shown or indicated with reasonable accu- racy in the Contract Documents, Contractor shall, promptly after becoming aware thereof and before further disturbing conditions affected thereby or performing any Work in connection therewith (except in an emergency as required by Paragraph 6.16.A), identify the owner of such Underground Facility and give written notice to EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 14 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT that owner and to Owner and Engineer. Engineer will promptly review the Under- ground Facility and determine the extent, if any, to which a change is required in the Contract Documents to reflect and document the consequences of the existence or location of the Underground Facility. During such time, Contractor shall be re- sponsible for the safety and protection of such Underground Facility. 2. If Engineer concludes that a change in the Contract Documents is required, a Work Change Directive or a Change Order will be issued to reflect and document such consequences. An equitable adjustment shall be made in the Contract Price or Con- tract Times, or both, to the extent that they are attributable to the existence or loca- tion of any Underground Facility that was not shown or indicated or not shown or indicated with reasonable accuracy in the Contract Documents and that Contractor did not know of and could not reasonably have been expected to be aware of or to have anticipated. If Owner and Contractor are unable to agree on entitlement to or on the amount or extent, if any, of any such adjustment in Contract Price or Con- tract Times, Owner or Contractor may make a Claim therefor as provided in Para- graph 10.05. 4.05 Reference Points A. Owner shall provide engineering surveys to establish reference points for construction which in Engineer's judgment are necessary to enable Contractor to proceed with the Work. Contractor shall be responsible for laying out the Work, shall protect and pre- serve the established reference points and property monuments, and shall make no changes or relocations without the prior written approval of Owner. Contractor shall report to Engineer whenever any reference point or property monument is lost or de- stroyed or requires relocation because of necessary changes in grades or locations, and shall be responsible for the accurate replacement or relocation of such reference points or property monuments by professionally qualified personnel. 4.06 Hazardous Environmental Condition at Site A. Reports and Drawings: The Supplementary Conditions identify those reports and drawings known to Owner relating to Hazardous Environmental Conditions that have been identified at the Site. B. Limited Reliance by Contractor on Technical Data Authorized: Contractor may rely upon the accuracy of the "technical data" contained in such reports and drawings, but such reports and drawings are not Contract Documents. Such "technical data" is identi- fied in the Supplementary Conditions. Except for such reliance on such "technical data," Contractor may not rely upon or make any claim against Owner or Engineer, or any of their officers, directors, members, partners, employees, agents, consultants, or subcontractors with respect to: 1. the completeness of such reports and drawings for Contractor's purposes, including, but not limited to, any aspects of the means, methods, techniques, sequences and EJCDC C•700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 15 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT procedures of construction to be employed by Contractor and safety precautions and programs incident thereto; or 2. other data, interpretations, opinions and information contained in such reports or shown or indicated in such drawings; or 3. any Contractor interpretation of or conclusion drawn from any "technical data" or any such other data, interpretations, opinions or information. C. Contractor shall not be responsible for any Hazardous Environmental Condition uncov- ered or revealed at the Site which was not shown or indicated in Drawings or Specifica- tions or identified in the Contract Documents to be within the scope of the Work. Con- tractor shall be responsible for a Hazardous Environmental Condition created with any materials brought to the Site by Contractor, Subcontractors, Suppliers, or anyone else for whom Contractor is responsible. D. If Contractor encounters a Hazardous Environmental Condition or if Contractor or any- one for whom Contractor is responsible creates a Hazardous Environmental Condition, Contractor shall immediately: (i) secure or otherwise isolate such condition; (ii) stop all Work in connection with such condition and in any area affected thereby (except in an emergency as required by Paragraph 6.16.A); and (iii) notify Owner and Engineer (and promptly thereafter confirm such notice in writing). Owner shall promptly consult with Engineer concerning the necessity for Owner to retain a qualified expert to evalu- ate such condition or take corrective action, if any. Promptly after consulting with En- gineer, Owner shall take such actions as are necessary to permit Owner to timely obtain required permits and provide Contractor the written notice required by Paragraph 4.06.E. E. Contractor shall not be required to resume Work in connection with such condition or in any affected area until after Owner has obtained any required permits related thereto and delivered written notice to Contractor: (i) specifying that such condition and any affected area is or has been rendered safe for the resumption of Work; or (ii) specifying any special conditions under which such Work may be resumed safely. If Owner and Contractor cannot agree as to entitlement to or on the amount or extent, if any, of any adjustment in Contract Price or Contract Times, or both, as a result of such Work stop- page or such special conditions under which Work is agreed to be resumed by Contrac- tor, either party may make a Claim therefor as provided in Paragraph 10.05. F. If after receipt of such written notice Contractor does not agree to resume such Work based on a reasonable belief it is unsafe, or does not agree to resume such Work under such special conditions, then Owner may order the portion of the Work that is in the area affected by such condition to be deleted from the Work. If Owner and Contractor cannot agree as to entitlement to or on the amount or extent, if any, of an adjustment in Contract Price or Contract Times as a result of deleting such portion of the Work, then either party may make a Claim therefor as provided in Paragraph 10.05. Owner may have such deleted portion of the Work performed by Owner's own forces or others in accordance with Article 7. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 16 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT G. To the fullest extent permitted by Laws and Regulations, Owner shall indemnify and hold harmless Contractor, Subcontractors, and Engineer, and the officers, directors, members, partners, employees, agents, consultants, and subcontractors of each and any of them from and against all claims, costs, losses, and damages (including but not lim- ited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) arising out of or relating to a Hazardous Environmental Condition, provided that such Hazardous Environmental Condition: (i) was not shown or indicated in the Drawings or Specifications or identi- fied in the Contract Documents to be included within the scope of the Work, and (ii) was not created by Contractor or by anyone for whom Contractor is responsible. Noth- ing in this Paragraph 4.06.G shall obligate Owner to indemnify any individual or entity from and against the consequences of that individual's or entity's own negligence. H. To the fullest extent permitted by Laws and Regulations, Contractor shall indemnify and hold harmless Owner and Engineer, and the officers, directors, members, partners, employees, agents, consultants, and subcontractors of each and any of them from and against all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbi- tration or other dispute resolution costs) arising out of or relating to a Hazardous Envi- ronmental Condition created by Contractor or by anyone for whom Contractor is re- sponsible. Nothing in this Paragraph 4.06.H shall obligate Contractor to indemnify any individual or entity from and against the consequences of that individual's or entity's own negligence. I. The provisions of Paragraphs 4.02, 4.03, and 4.04 do not apply to a Hazardous Envi- ronmental Condition uncovered or revealed at the Site. ARTICLE 5 — BONDS AND INSURANCE 5.01 Pei formance, Payment, and Other Bonds A. Contractor shall furnish performance and payment bonds, each in an amount at least equal to the Contract Price as security for the faithful performance and payment of all of Contractor's obligations under the Contract Documents. These bonds shall remain in effect until one year after the date when final payment becomes due or until comple- tion of the correction period specified in Paragraph 13.07, whichever is later, except as provided otherwise by Laws or Regulations or by the Contract Documents. Contractor shall also furnish such other bonds as are required by the Contract Documents. B. All bonds shall be in the form prescribed by the Contract Documents except as pro- vided otherwise by Laws or Regulations, and shall be executed by such sureties as are named in the list of "Companies Holding Certificates of Authority as Acceptable Sure- ties on Federal Bonds and as Acceptable Reinsuring Companies" as published in Circu- lar 570 (amended) by the Financial Management Service, Surety Bond Branch, U.S. Department of the Treasury. All bonds signed by an agent or attorney -in -fact must be accompanied by a certified copy of that individual's authority to bind the surety. The EJCDC C•700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 17 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT evidence of authority shall show that it is effective on the date the agent or attorney -in - fact signed each bond. C. If the surety on any bond furnished by Contractor is declared bankrupt or becomes in- solvent or its right to do business is terminated in any state where any part of the Pro- ject is located or it ceases to meet the requirements of Paragraph 5.0l.B, Contractor shall promptly notify Owner and Engineer and shall, within 20 days after the event giv- ing rise to such notification, provide another bond and surety, both of which shall com- ply with the requirements of Paragraphs 5.01.13 and 5.02. 5.02 Licensed Sureties and Insurers A. All bonds and insurance required by the Contract Documents to be purchased and maintained by Owner or Contractor shall be obtained from surety or insurance compa- nies that are duly licensed or authorized in the jurisdiction in which the Project is lo- cated to issue bonds or insurance policies for the limits and coverages so required. Such surety and insurance companies shall also meet such additional requirements and qualifications as may be provided in the Supplementary Conditions. 5.03 Certificates of Insurance A. Contractor shall deliver to Owner, with copies to each additional insured and loss payee identified in the Supplementary Conditions, certificates of insurance (and other evi- dence of insurance requested by Owner or any other additional insured) which Contrac- tor is required to purchase and maintain. B. Owner shall deliver to Contractor, with copies to each additional insured and loss payee identified in the Supplementary Conditions, certificates of insurance (and other evi- dence of insurance requested by Contractor or any other additional insured) which Owner is required to purchase and maintain. C. Failure of Owner to demand such certificates or other evidence of Contractor's full compliance with these insurance requirements or failure of Owner to identify a defi- ciency in compliance from the evidence provided shall not be construed as a waiver- of Contractor's obligation to maintain such insurance. D. Owner does not represent that insurance coverage and limits established in this Con- tract necessarily will be adequate to protect Contractor. E. The insurance and insurance limits required herein shall not be deemed as a limitation on Contractor's liability under the indemnities granted to Owner in the Contract Docu- ments. 5.04 Contractor's Insurance A. Contractor shall purchase and maintain such insurance as is appropriate for the Work being performed and as will provide protection from claims set forth below which may EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 18 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT arise out of or result from Contractor's performance of the Work and Contractor's other obligations under the Contract Documents, whether it is to be performed by Contractor, any Subcontractor or Supplier, or by anyone directly or indirectly employed by any of them to perform any of the Work, or by anyone for whose acts any of them may be li- able: 1. claims under workers' compensation, disability benefits, and other similar em- ployee benefit acts; 2. claims for damages because of bodily injury, occupational sickness or disease, or death of Contractor's employees; 3. claims for damages because of bodily injury, sickness or disease, or death of any person other than Contractor's employees; 4. claims for damages insured by reasonably available personal injury liability cover- age which are sustained: a. by any person as a result of an offense directly or indirectly related to the em- ployment of such person by Contractor, or b. by any other person for any other reason; 5. claims for damages, other than to the Work itself, because of injury to or destruc- tion of tangible property wherever located, including loss of use resulting there- from; and 6. claims for damages because of bodily injury or death of any person or property damage arising out of the ownership, maintenance or use of any motor vehicle. B. The policies of insurance required by this Paragraph 5.04 shall: with respect to insurance required by Paragraphs 5.04.A.3 through 5.04.A.6 inclu- sive, be written on an occurrence basis, include as additional insureds (subject to any customary exclusion regarding professional liability) Owner and Engineer, and any other individuals or entities identified in the Supplementary Conditions, all of whom shall be listed as additional insureds, and include coverage for the respective officers, directors, members, partners, employees, agents, consultants, and subcon- tractors of each and any of all such additional insureds, and the insurance afforded to these additional insureds shall provide primary coverage for all claims covered thereby; 2. include at least the specific coverages and be written for not less than the limits of liability provided in the Supplementary Conditions or required by Laws or Regula- tions, whichever is greater; 3. include contractual liability insurance covering Contractor's indemnity obligations under Paragraphs 6.11 and 6.20; EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 19 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 4. contain a provision or endorsement that the coverage afforded will not be canceled, materially changed or renewal refused until at least 30 days prior written notice has been given to Owner and Contractor and to each other additional insured identified in the Supplementary Conditions to whom a certificate of insurance has been issued (and the certificates of insurance furnished by the Contractor pursuant to Paragraph 5.03 will so provide); 5. remain in effect at least until final payment and at all times thereafter when Con- tractor may be correcting, removing, or replacing defective Work in accordance with Paragraph 13.07; and 6. include completed operations coverage: a. Such insurance shall remain in effect for two years after final payment. b. Contractor shall furnish Owner and each other additional insured identified in the Supplementary Conditions, to whom a certificate of insurance has been is- sued, evidence satisfactory to Owner and any such additional insured of con- tinuation of such insurance at final payment and one year thereafter. 5.05 Owner's Liability Insurance A. In addition to the insurance required to be provided by Contractor under Paragraph 5.04, Owner, at Owner's option, may purchase and maintain at Owner's expense Owner's own liability insurance as will protect Owner against claims which may arise from operations under the Contract Documents. 5.06 Property Insurance A. Unless otherwise provided in the Supplementary Conditions, Owner shall purchase and maintain property insurance upon the Work at the Site in the amount of the full re- placement cost thereof (subject to such deductible amounts as may be provided in the Supplementary Conditions or required by Laws and Regulations). This insurance shall: 1. include the interests of Owner, Contractor, Subcontractors, and Engineer, and any other individuals or entities identified in the Supplementary Conditions, and the of- ficers, directors, members, partners, employees, agents, consultants, and subcon- tractors of each and any of them, each of whom is deemed to have an insurable in- terest and shall be listed as a loss payee; 2. be written on a Builder's Risk "all-risk" policy form that shall at least include in- surance for physical loss or damage to the Work, temporary buildings, falsework, and materials and equipment in transit, and shall insure against at least the follow- ing perils or causes of loss: fire, lightning, extended coverage, theft, vandalism and malicious mischief, earthquake, collapse, debris removal, demolition occasioned by enforcement of Laws and Regulations, water damage (other than that caused by EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 20 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT flood), and such other perils or causes of loss as may be specifically required by the Supplementary Conditions. 3. include expenses incurred in the repair or replacement of any insured property (in- cluding but not limited to fees and charges of engineers and architects); 4. cover materials and equipment stored at the Site or at another location that was agreed to in writing by Owner prior to being incorporated in the Work, provided that such materials and equipment have been included in an Application for Pay- ment recommended by Engineer; 5. allow for partial utilization of the Work by Owner; 6. include testing and startup; and be maintained in effect until final payment is made unless otherwise agreed to in writing by Owner, Contractor, and Engineer with 30 days written notice to each other loss payee to whom a certificate of insurance has been issued. B. Owner shall purchase and maintain such equipment breakdown insurance or additional property insurance as may be required by the Supplementary Conditions or Laws and Regulations which will include the interests of Owner, Contractor, Subcontractors, and Engineer, and any other individuals or entities identified in the Supplementary Condi- tions, and the officers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them, each of whom is deemed to have an insurable interest and shall be listed as a loss payee. C. All the policies of insurance (and the certificates or other evidence thereof) required to be purchased and maintained in accordance with this Paragraph 5.06 will contain a pro- vision or endorsement that the coverage afforded will not be canceled or materially changed or renewal refused until at least 30 days prior written notice has been given to Owner and Contractor and to each other loss payee to whom a certificate of insurance has been issued and will contain waiver provisions in accordance with Paragraph 5.07. D. Owner shall not be responsible for purchasing and maintaining any property insurance specified in this Paragraph 5.06 to protect the interests of Contractor, Subcontractors, or others in the Work to the extent of any deductible amounts that are identified in the Supplementary Conditions. The risk of loss within such identified deductible amount will be borne by Contractor, Subcontractors, or others suffering any such loss, and if any of them wishes property insurance coverage within the limits of such amounts, each may purchase and maintain it at the purchaser's own expense. E. If Contractor requests in writing that other special insurance be included in the property insurance policies provided under this Paragraph 5.06, Owner shall, if possible, include such insurance, and the cost thereof will be charged to Contractor by appropriate Change Order. Prior to commencement of the Work at the Site, Owner shall in writing advise Contractor whether or not such other insurance has been procured by Owner. EJCDC C•700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 21 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 5.07 Waiver of Rights A. Owner and Contractor intend that all policies purchased in accordance with Paragraph 5.06 will protect Owner, Contractor, Subcontractors, and Engineer, and all other indi- viduals or entities identified in the Supplementary Conditions as loss payees (and the officers, directors, members, partners, employees, agents, consultants, and subcontrac- tors of each and any of them) in such policies and will provide primary coverage for all losses and damages caused by the perils or causes of loss covered thereby. All such policies shall contain provisions to the effect that in the event of payment of any loss or damage the insurers will have no rights of recovery against any of the insureds or loss payees thereunder. Owner and Contractor waive all rights against each other and their respective officers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them for all losses and damages caused by, arising out of or resulting from any of the perils or causes of loss covered by such policies and any other property insurance applicable to the Work; and, in addition, waive all such rights against Subcontractors and Engineer, and all other individuals or entities identi- fied in the Supplementary Conditions as loss payees (and the officers, directors, mem- bers, partners, employees, agents, consultants, and subcontractors of each and any of them) under such policies for losses and damages so caused. None of the above waiv- ers shall extend to the rights that any party making such waiver may have to the pro- ceeds of insurance held by Owner as trustee or otherwise payable under any policy so issued. B. Owner waives all rights against Contractor, Subcontractors, and Engineer, and the offi- cers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them for: 1. loss due to business interruption, loss of use, or other consequential loss extending beyond direct physical loss or damage to Owner's property or the Work caused by, arising out of, or resulting from fire or other perils whether or not insured by Owner; and 2. loss or damage to the completed Project or part thereof caused by, arising out of, or resulting from fire or other insured peril or cause of loss covered by any property insurance maintained on the completed Project or part thereof by Owner during par- tial utilization pursuant to Paragraph 14.05, after Substantial Completion pursuant to Paragraph 14.04, or after final payment pursuant to Paragraph 14.07. C. Any insurance policy maintained by Owner covering any loss, damage or consequential loss referred to in Paragraph 5.07.13 shall contain provisions to the effect that in the event of payment of any such loss, damage, or consequential loss, the insurers will have no rights of recovery against Contractor, Subcontractors, or Engineer, and the officers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 22 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 5.08 Receipt and Application of Insurance Proceeds A. Any insured loss under the policies of insurance required by Paragraph 5.06 will be ad- justed with Owner and made payable to Owner as fiduciary for the loss payees, as their interests may appear, subject to the requirements of any applicable mortgage clause and of Paragraph 5.08.13. Owner shall deposit in a separate account any money so received and shall distribute it in accordance with such agreement as the parties in interest may reach. If no other special agreement is reached, the damaged Work shall be repaired or replaced, the moneys so received applied on account thereof, and the Work and the cost thereof covered by an appropriate Change Order. B. Owner as fiduciary shall have power to adjust and settle any loss with the insurers unless one of the parties in interest shall object in writing within 15 days after the oc- currence of loss to Owner's exercise of this power. If such objection be made, Owner as fiduciary shall make settlement with the insurers in accordance with such agreement as the parties in interest may reach. If no such agreement among the parties in interest is reached, Owner as fiduciary shall adjust and settle the loss with the insurers and, if required in writing by any party in interest, Owner as fiduciary shall give bond for the proper performance of such duties. 5.09 Acceptance of Bonds and Insurance; Option to Replace A. If either Owner or Contractor has any objection to the coverage afforded by or other provisions of the bonds or insurance required to be purchased and maintained by the other party in accordance with Article 5 on the basis of non-conformance with the Con- tract Documents, the objecting party shall so notify the other party in writing within 10 days after receipt of the certificates (or other evidence requested) required by Paragraph 2.01.13. Owner and Contractor shall each provide to the other such additional informa- tion in respect of insurance provided as the other may reasonably request. If either party does not purchase or maintain all of the bonds and insurance required of such party by the Contract Documents, such party shall notify the other party in writing of such failure to purchase prior to the start of the Work, or of such failure to maintain prior to any change in the required coverage. Without prejudice to any other right or remedy, the other party may elect to obtain equivalent bonds or insurance to protect such other party's interests at the expense of the party who was required to provide such coverage, and a Change Order shall be issued to adjust the Contract Price accord- ingly. 5.10 Partial Utilization, Acknowledgment of Property Insurer A. If Owner finds it necessary to occupy or use a portion or portions of the Work prior to Substantial Completion of all the Work as provided in Paragraph 14.05, no such use or occupancy shall commence before the insurers providing the property insurance pursu- ant to Paragraph 5.06 have acknowledged notice thereof and in writing effected any changes in coverage necessitated thereby. The insurers providing the property insur- ance shall consent by endorsement on the policy or policies, but the property insurance EJCDC C-700 Standard General Conditions of the Construction Contract Copyright @ 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 23 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT shall not be canceled or permitted to lapse on account of any such partial use or occu- pancy. ARTICLE 6 — CONTRACTOR'S RESPONSIBILITIES 6.01 Supervision and Superintendence A. Contractor shall supervise, inspect, and direct the Work competently and efficiently, devoting such attention thereto and applying such skills and expertise as may be neces- sary to perform the Work in accordance with the Contract Documents. Contractor shall be solely responsible for the means, methods, techniques, sequences, and procedures of construction. Contractor shall not be responsible for the negligence of Owner or Engi- neer in the design or specification of a specific means, method, technique, sequence, or procedure of construction which is shown or indicated in and expressly required by the Contract Documents. B. At all times during the progress of the Work, Contractor shall assign a competent resi- dent superintendent who shall not be replaced without written notice to Owner and En- gineer except under extraordinary circumstances. 6.02 Labor; Working Hours A. Contractor shall provide competent, suitably qualified personnel to survey and lay out the Work and perform construction as required by the Contract Documents. Contractor shall at all times maintain good discipline and order at the Site. B. Except as otherwise required for the safety or protection of persons or the Work or property at the Site or adjacent thereto, and except as otherwise stated in the Contract Documents, all Work at the Site shall be performed during regular working hours. Contractor will not permit the performance of Work on a Saturday, Sunday, or any le- gal holiday without Owner's written consent (which will not be unreasonably withheld) given after prior written notice to Engineer. 6.03 Services, Materials, and Equipment A. Unless otherwise specified in the Contract Documents, Contractor shall provide and as- sume full responsibility for all services, materials, equipment, labor, transportation, construction equipment and machinery, tools, appliances, fuel, power, light, heat, tele- phone, water, sanitary facilities, temporary facilities, and all other facilities and inciden- tals necessary for the performance, testing, start-up, and completion of the Work. B. All materials and equipment incorporated into the Work shall be as specified or, if not specified, shall be of good quality and new, except as otherwise provided in the Con- tract Documents. All special warranties and guarantees required by the Specifications shall expressly run to the benefit of Owner. If required by Engineer, Contractor shall furnish satisfactory evidence (including reports of required tests) as to the source, kind, and quality of materials and equipment. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 24 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT C. All materials and equipment shall be stored, applied, installed, connected, erected, pro- tected, used, cleaned, and conditioned in accordance with instructions of the applicable Supplier, except as otherwise may be provided in the Contract Documents. 6.04 Progress Schedule A. Contractor shall adhere to the Progress Schedule established in accordance with Para- graph 2.07 as it may be adjusted from time to time as provided below. 1. Contractor shall submit to Engineer for acceptance (to the extent indicated in Para- graph 2.07) proposed adjustments in the Progress Schedule that will not result in changing the Contract Times. Such adjustments will comply with any provisions of the General Requirements applicable thereto. 2. Proposed adjustments in the Progress Schedule that will change the Contract Times shall be submitted in accordance with the requirements of Article 12. Adjustments in Contract Times may only be made by a Change Order. 6.05 Substitutes and "Or -Equals" A. Whenever an item of material or equipment is specified or described in the Contract Documents by using the name of a proprietary item or the name of a particular Sup- plier, the specification or description is intended to establish the type, function, appear- ance, and quality required. Unless the specification or description contains or is fol- lowed by words reading that no like, equivalent, or "or -equal" item or no substitution is permitted, other items of material or equipment or material or equipment of other Sup- pliers may be submitted to Engineer for review under the circumstances described be- low. "Or -Equal" Items: If in Engineer's sole discretion an item of material or equipment proposed by Contractor is functionally equal to that named and sufficiently similar so that no change in related Work will be required, it may be considered by Engi- neer as an "or -equal" item, in which case review and approval of the proposed item may, in Engineer's sole discretion, be accomplished without compliance with some or all of the requirements for approval of proposed substitute items. For the pur- poses of this Paragraph 6.05.A.1, a proposed item of material or equipment will be considered functionally equal to an item so named if: a. in the exercise of reasonable judgment Engineer determines that: 1) it is at least equal in materials of construction, quality, durability, appear- ance, strength, and design characteristics; 2) it will reliably perform at least equally well the function and achieve the re- sults imposed by the design concept of the completed Project as a function- ing whole; and EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 25 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 3) it has a proven record of performance and availability of responsive service. b. Contractor certifies that, if approved and incorporated into the Work: 1) there will be no increase in cost to the Owner or increase in Contract Times; and 2) it will conform substantially to the detailed requirements of the item named in the Contract Documents. 2. Substitute Items: a. If in Engineer's sole discretion an item of material or equipment proposed by Contractor does not qualify as an "or -equal" item under Paragraph 6.05.A.1, it will be considered a proposed substitute item. b. Contractor shall submit sufficient information as provided below to allow Engi- neer to determine if the item of material or equipment proposed is essentially equivalent to that named and an acceptable substitute therefor. Requests for re- view of proposed substitute items of material or equipment will not be accepted by Engineer from anyone other than Contractor. c. The requirements for review by Engineer will be as set forth in Paragraph 6.05.A.2.d, as supplemented by the General Requirements, and as Engineer may decide is appropriate under the circumstances. d. Contractor shall make written application to Engineer for review of a proposed substitute item of material or equipment that Contractor seeks to furnish or use. The application: 1) shall certify that the proposed substitute item will: a) perform adequately the functions and achieve the results called for by the general design, b) be similar in substance to that specified, and c) be suited to the same use as that specified; 2) will state: a) the extent, if any, to which the use of the proposed substitute item will prejudice Contractor's achievement of Substantial Completion on time, b) whether use of the proposed substitute item in the Work will require a change in any of the Contract Documents (or in the provisions of any other direct contract with Owner for other work on the Project) to adapt the design to the proposed substitute item, and EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 26 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT c) whether incorporation or use of the proposed substitute item in con- nection with the Work is subject to payment of any license fee or roy- alty; 3) will identify: a) all variations of the proposed substitute item from that specified, and b) available engineering, sales, maintenance, repair, and replacement ser- vices; and 4) shall contain an itemized estimate of all costs or credits that will result di- rectly or indirectly from use of such substitute item, including costs of re- design and claims of other contractors affected by any resulting change. B. Substitute Construction Methods or Procedures: If a specific means, method, tech- nique, sequence, or procedure of construction is expressly required by the Contract Documents, Contractor may furnish or utilize a substitute means, method, technique, sequence, or procedure of construction approved by Engineer. Contractor shall submit sufficient information to allow Engineer, in Engineer's sole discretion, to determine that the substitute proposed is equivalent to that expressly called for by the Contract Documents. The requirements for review by Engineer will be similar to those provided in Paragraph 6.05.A.2. C. Engineer's Evaluation: Engineer will be allowed a reasonable time within which to evaluate each proposal or submittal made pursuant to Paragraphs 6.05.A and 6.05.13. Engineer may require Contractor to furnish additional data about the proposed substi- tute item. Engineer will be the sole judge of acceptability. No "or equal" or substitute will be ordered, installed or utilized until Engineer's review is complete, which will be evidenced by a Change Order in the case of a substitute and an approved Shop Drawing for an "or equal." Engineer will advise Contractor in writing of any negative determina- tion. D. Special Guarantee: Owner may require Contractor to furnish at Contractor's expense a special performance guarantee or other surety with respect to any substitute. E. Engineer's Cost Reimbursement. Engineer will record Engineer's costs in evaluating a substitute proposed or submitted by Contractor pursuant to Paragraphs 6.05.A.2 and 6.05.13. Whether or not Engineer approves a substitute so proposed or submitted by Contractor, Contractor shall reimburse Owner for the reasonable charges of Engineer for evaluating each such proposed substitute. Contractor shall also reimburse Owner for the reasonable charges of Engineer for making changes in the Contract Documents (or in the provisions of any other direct contract with Owner) resulting from the accep- tance of each proposed substitute. F. Contractor's Expense: Contractor shall provide all data in support of any proposed substitute or "or -equal" at Contractor's expense. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 27 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 6.06 Concerning Subcontractors, Suppliers, and Others A. Contractor shall not employ any Subcontractor, Supplier, or other individual or entity (including those acceptable to Owner as indicated in Paragraph 6.06.B), whether ini- tially or as a replacement, against whom Owner may have reasonable objection. Con- tractor shall not be required to employ any Subcontractor, Supplier, or other individual or entity to furnish or perform any of the Work against whom Contractor has reason- able objection. B. If the Supplementary Conditions require the identity of certain Subcontractors, Suppli- ers, or other individuals or entities to be submitted to Owner in advance for acceptance by Owner by a specified date prior to the Effective Date of the Agreement, and if Con- tractor has submitted a list thereof in accordance with the Supplementary Conditions, Owner's acceptance (either in writing or by failing to make written objection thereto by the date indicated for acceptance or objection in the Bidding Documents or the Contract Documents) of any such Subcontractor, Supplier, or other individual or entity so identi- fied may be revoked on the basis of reasonable objection after due investigation. Con- tractor shall submit an acceptable replacement for the rejected Subcontractor, Supplier, or other individual or entity, and the Contract Price will be adjusted by the difference in the cost occasioned by such replacement, and an appropriate Change Order will be is- sued. No acceptance by Owner of any such Subcontractor, Supplier, or other individual or entity, whether initially or as a replacement, shall constitute a waiver of any right of Owner or Engineer to reject defective Work. C. Contractor shall be fully responsible to Owner and Engineer for all acts and omissions of the Subcontractors, Suppliers, and other individuals or entities performing or furnish- ing any of the Work just as Contractor is responsible for Contractor's own acts and omissions. Nothing in the Contract Documents: shall create for the benefit of any such Subcontractor, Supplier, or other individual or entity any contractual relationship between Owner or Engineer and any such Subcontractor, Supplier or other individual or entity; nor 2. shall create any obligation on the part of Owner or Engineer to pay or to see to the payment of any moneys due any such Subcontractor, Supplier, or other individual or entity except as may otherwise be required by Laws and Regulations. D. Contractor shall be solely responsible for scheduling and coordinating the Work of Subcontractors, Suppliers, and other individuals or entities performing or furnishing any of the Work under a direct or indirect contract with Contractor. E. Contractor shall require all Subcontractors, Suppliers, and such other individuals or en- tities performing or furnishing any of the Work to communicate with Engineer through Contractor. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright ® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 28 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT F. The divisions and sections of the Specifications and the identifications of any Drawings shall not control Contractor in dividing the Work among Subcontractors or Suppliers or delineating the Work to be performed by any specific trade. G. All Work performed for Contractor by a Subcontractor or Supplier will be pursuant to an appropriate agreement between Contractor and the Subcontractor or Supplier which specifically binds the Subcontractor or Supplier to the applicable terms and conditions of the Contract Documents for the benefit of Owner and Engineer. Whenever any such agreement is with a Subcontractor or Supplier who is listed as a loss payee on the prop- erty insurance provided in Paragraph 5.06, the agreement between the Contractor and the Subcontractor or Supplier will contain provisions whereby the Subcontractor or Supplier waives all rights against Owner, Contractor, Engineer, and all other individu- als or entities identified in the Supplementary Conditions to be listed as insureds or loss payees (and the officers, directors, members, partners, employees, agents, consultants, and subcontractors of each and any of them) for all losses and damages caused by, aris- ing out of, relating to, or resulting from any of the perils or causes of loss covered by such policies and any other property insurance applicable to the Work. If the insurers on any such policies require separate waiver forms to be signed by any Subcontractor or Supplier, Contractor will obtain the same. 6.07 Patent Fees and Royalties A. Contractor shall pay all license fees and royalties and assume all costs incident to the use in the performance of the Work or the incorporation in the Work of any invention, design, process, product, or device which is the subject of patent rights or copyrights held by others. If a particular invention, design, process, product, or device is specified in the Contract Documents for use in the performance of the Work and if, to the actual knowledge of Owner or Engineer, its use is subject to patent rights or copyrights calling for the payment of any license fee or royalty to others, the existence of such rights shall be disclosed by Owner in the Contract Documents. B. To the fullest extent permitted by Laws and Regulations, Owner shall indemnify and hold harmless Contractor, and its officers, directors, members, partners, employees, agents, consultants, and subcontractors from and against all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, at- torneys, and other professionals, and all court or arbitration or other dispute resolution costs) arising out of or relating to any infringement of patent rights or copyrights inci- dent to the use in the performance of the Work or resulting from the incorporation in the Work of any invention, design, process, product, or device specified in the Contract Documents, but not identified as being subject to payment of any license fee or royalty to others required by patent rights or copyrights. C. To the fullest extent permitted by Laws and Regulations, Contractor shall indemnify and hold harmless Owner and Engineer, and the officers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them from and against all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbi- EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 29 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT tration or other dispute resolution costs) arising out of or relating to any infringement of patent rights or copyrights incident to the use in the performance of the Work or result- ing from the incorporation in the Work of any invention, design, process, product, or device not specified in the Contract Documents. 6.08 Permits A. Unless otherwise provided in the Supplementary Conditions, Contractor shall obtain and pay for all construction permits and licenses. Owner shall assist Contractor, when necessary, in obtaining such permits and licenses. Contractor shall pay all governmen- tal charges and inspection fees necessary for the prosecution of the Work which are ap- plicable at the time of opening of Bids, or, if there are no Bids, on the Effective Date of the Agreement. Owner shall pay all charges of utility owners for connections for pro- viding permanent service to the Work. 6.09 Laws and Regulations A. Contractor shall give all notices required by and shall comply with all Laws and Regu- lations applicable to the performance of the Work. Except where otherwise expressly required by applicable Laws and Regulations, neither Owner nor Engineer shall be re- sponsible for monitoring Contractor's compliance with any Laws or Regulations. B. If Contractor performs any Work knowing or having reason to know that it is contrary to Laws or Regulations, Contractor shall bear all claims, costs, losses, and damages (in- cluding but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) arising out of or relating to such Work. However, it shall not be Contractor's responsibility to make certain that the Specifications and Drawings are in accordance with Laws and Regulations, but this shall not relieve Contractor of Contractor's obligations under Paragraph 3.03. C. Changes in Laws or Regulations not known at the time of opening of Bids (or, on the Effective Date of the Agreement if there were no Bids) having an effect on the cost or time of performance of the Work shall be the subject of an adjustment in Contract Price or Contract Times. If Owner and Contractor are unable to agree on entitlement to or on the amount or extent, if any, of any such adjustment, a Claim may be made therefor as provided in Paragraph 10.05. 6.10 Taxes A. Contractor shall pay all sales, consumer, use, and other similar taxes required to be paid by Contractor in accordance with the Laws and Regulations of the place of the Project which are applicable during the performance of the Work. 6.11 Use of Site and Other Areas A. Limitation on Use of Site and Other Areas: EJCDC C-700 Standard General Conditions of the Construction Contract Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 30 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 1. Contractor shall confine construction equipment, the storage of materials and equipment, and the operations of workers to the Site and other areas permitted by Laws and Regulations, and shall not unreasonably encumber the Site and other ar- eas with construction equipment or other materials or equipment. Contractor shall assume full responsibility for any damage to any such land or area, or to the owner or occupant thereof, or of any adjacent land or areas resulting from the performance of the Work. 2. Should any claim be made by any such owner or occupant because of the perform- ance of the Work, Contractor shall promptly settle with such other party by negotia- tion or otherwise resolve the claim by arbitration or other dispute resolution pro- ceeding or at law. 3. To the fullest extent permitted by Laws and Regulations, Contractor shall indem- nify and hold harmless Owner and Engineer, and the officers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them from and against all claims, costs, losses, and damages (including but not lim- ited to all fees and charges of engineers, architects, attorneys, and other profession- als and all court or arbitration or other dispute resolution costs) arising out of or re- lating to any claim or action, legal or equitable, brought by any such owner or oc- cupant against Owner, Engineer, or any other party indemnified hereunder to the extent caused by or based upon Contractor's performance of the Work. B. Removal of Debris During Perfonnance of the Work: During the progress of the Work Contractor shall keep the Site and other areas free from accumulations of waste materi- als, rubbish, and other debris. Removal and disposal of such waste materials, rubbish, and other debris shall conform to applicable Laws and Regulations. C. Cleaning: Prior to Substantial Completion of the Work Contractor shall clean the Site and the Work and make it ready for utilization by Owner. At the completion of the Work Contractor shall remove from the Site all tools, appliances, construction equip- ment and machinery, and surplus materials and shall restore to original condition all property not designated for alteration by the Contract Documents. D. Loading Structures: Contractor shall not load nor permit any part of any structure to be loaded in any manner that will endanger the structure, nor shall Contractor subject any part of the Work or adjacent property to stresses or pressures that will endanger it. 6.12 Record Documents A. Contractor shall maintain in a safe place at the Site one record copy of all Drawings, Specifications, Addenda, Change Orders, Work Change Directives, Field Orders, and written interpretations and clarifications in good order and annotated to show changes made during construction. These record documents together with all approved Samples and a counterpart of all approved Shop Drawings will be available to Engineer for ref- erence. Upon completion of the Work, these record documents, Samples, and Shop Drawings will be delivered to Engineer for Owner. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 31 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 6.13 Safety and Protection A. Contractor shall be solely responsible for initiating, maintaining and supervising all safety precautions and programs in connection with the Work. Such responsibility does not relieve Subcontractors of their responsibility for the safety of persons or property in the performance of their work, nor for compliance with applicable safety Laws and Regulations. Contractor shall take all necessary precautions for the safety of, and shall provide the necessary protection to prevent damage, injury or loss to: 1. all persons on the Site or who may be affected by the Work; 2. all the Work and materials and equipment to be incorporated therein, whether in storage on or off the Site; and other property at the Site or adjacent thereto, including trees, shrubs, lawns, walks, pavements, roadways, structures, utilities, and Underground Facilities not desig- nated for removal, relocation, or replacement in the course of construction. B. Contractor shall comply with all applicable Laws and Regulations relating to the safety of persons or property, or to the protection of persons or property from damage, injury, or loss; and shall erect and maintain all necessary safeguards for such safety and protec- tion. Contractor shall notify owners of adjacent property and of Underground Facilities and other utility owners when prosecution of the Work may affect them, and shall co- operate with them in the protection, removal, relocation, and replacement of their prop- erty. C. Contractor shall comply with the applicable requirements of Owner's safety programs, if any. The Supplementary Conditions identify any Owner's safety programs that are applicable to the Work. D. Contractor shall inform Owner and Engineer of the specific requirements of Contrac- tor's safety program with which Owner's and Engineer's employees and representa- tives must comply while at the Site. E. All damage, injury, or loss to any property referred to in Paragraph 6.13.A.2 or 6.13.A.3 caused, directly or indirectly, in whole or in part, by Contractor, any Subcon- tractor, Supplier, or any other individual or entity directly or indirectly employed by any of them to perform any of the Work, or anyone for whose acts any of them may be liable, shall be remedied by Contractor (except damage or loss attributable to the fault of Drawings or Specifications or to the acts or omissions of Owner or Engineer or any- one employed by any of them, or anyone for whose acts any of them may be liable, and not attributable, directly or indirectly, in whole or in part, to the fault or negligence of Contractor or any Subcontractor, Supplier, or other individual or entity directly or indi- rectly employed by any of them). F. Contractor's duties and responsibilities for safety and for protection of the Work shall continue until such time as all the Work is completed and Engineer has issued a notice EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 32 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT to Owner and Contractor in accordance with Paragraph 14.07.13 that the Work is ac- ceptable (except as otherwise expressly provided in connection with Substantial Com- pletion). 6.14 Safety Representative A. Contractor shall designate a qualified and experienced safety representative at the Site whose duties and responsibilities shall be the prevention of accidents and the maintain- ing and supervising of safety precautions and programs. 6.15 Hazard Communication Programs A. Contractor shall be responsible for coordinating any exchange of material safety data sheets or other hazard communication information required to be made available to or exchanged between or among employers at the Site in accordance with Laws or Regu- lations. 6.16 Emergencies A. In emergencies affecting the safety or protection of persons or the Work or property at the Site or adjacent thereto, Contractor is obligated to act to prevent threatened damage, injury, or loss. Contractor shall give Engineer prompt written notice if Contractor be- lieves that any significant changes in the Work or variations from the Contract Docu- ments have been caused thereby or are required as a result thereof. If Engineer deter- mines that a change in the Contract Documents is required because of the action taken by Contractor in response to such an emergency, a Work Change Directive or Change Order will be issued. 6.17 Shop Drawings and Samples A. Contractor shall submit Shop Drawings and Samples to Engineer for review and ap- proval in accordance with the accepted Schedule of Submittals (as required by Para- graph 2.07). Each submittal will be identified as Engineer may require. 1. Shop Drawings: a. Submit member of copies specified in the General Requirements. b. Data shown on the Shop Drawings will be complete with respect to quantities, dimensions, specified performance and design criteria, materials, and similar data to show Engineer the services, materials, and equipment Contractor pro- poses to provide and to enable Engineer to review the information for the lim- ited purposes required by Paragraph 6.17.D. 2. Samples: a. Submit number of Samples specified in the Specifications. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 33 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT b. Clearly identify each Sample as to material, Supplier, pertinent data such as catalog numbers, the use for which intended and other data as Engineer may re- quire to enable Engineer to review the submittal for the limited purposes re- quired by Paragraph 6.17.D. B. Where a Shop Drawing or Sample is required by the Contract Documents or the Schedule of Submittals, any related Work performed prior to Engineer's review and approval of the pertinent submittal will be at the sole expense and responsibility of Contractor. C. Submittal Procedures: 1. Before submitting each Shop Drawing or Sample, Contractor shall have: a. reviewed and coordinated each Shop Drawing or Sample with other Shop Drawings and Samples and with the requirements of the Work and the Contract Documents; b. determined and verified all field measurements, quantities, dimensions, speci- fied performance and design criteria, installation requirements, materials, cata- log numbers, and similar information with respect thereto; c. determined and verified the suitability of all materials offered with respect to the indicated application, fabrication, shipping, handling, storage, assembly, and installation pertaining to the performance of the Work; and d. determined and verified all information relative to Contractor's responsibilities for means, methods, techniques, sequences, and procedures of construction, and safety precautions and programs incident thereto. 2. Each submittal shall bear a stamp or specific written certification that Contractor has satisfied Contractor's obligations under the Contract Documents with respect to Contractor's review and approval of that submittal. 3. With each submittal, Contractor shall give Engineer specific written notice of any variations that the Shop Drawing or Sample may have from the requirements of the Contract Documents. This notice shall be both a written communication separate from the Shop Drawings or Sample submittal; and, in addition, by a specific nota- tion made on each Shop Drawing or Sample submitted to Engineer for review and approval of each such variation. D. Engineer's Review: 1. Engineer will provide timely review of Shop Drawings and Samples in accordance with the Schedule of Submittals acceptable to Engineer. Engineer's review and ap- proval will be only to determine if the items covered by the submittals will, after in- stallation or incorporation in the Work, conform to the information given in the EJCDC C•700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 34 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT Contract Documents and be compatible with the design concept of the completed Project as a functioning whole as indicated by the Contract Documents. 2. Engineer's review and approval will not extend to means, methods, techniques, se- quences, or procedures of construction (except where a particular means, method, technique, sequence, or procedure of construction is specifically and expressly called for by the Contract Documents) or to safety precautions or programs incident thereto. The review and approval of a separate item as such will not indicate ap- proval of the assembly in which the item functions. Engineer's review and approval shall not relieve Contractor from responsibility for any variation from the requirements of the Contract Documents unless Contractor has complied with the requirements of Paragraph 6.17.C.3 and Engineer has given written approval of each such variation by specific written notation thereof incorpo- rated in or accompanying the Shop Drawing or Sample. Engineer's review and ap- proval shall not relieve Contactor from responsibility for complying with the re- quirements of Paragraph 6.17.C.I. E. Resubrnittal Procedures: Contractor shall make corrections required by Engineer and shall return the re- quired number of corrected copies of Shop Drawings and submit, as required, new Samples for review and approval. Contractor shall direct specific attention in writ- ing to revisions other than the corrections called for by Engineer on previous sub- mittals. 6.18 Continuing the Work A. Contractor shall cant' on the Work and adhere to the Progress Schedule during all dis- putes or disagreements with Owner. No Work shall be delayed or postponed pending resolution of any disputes or disagreements, except as permitted by Paragraph 15.04 or as Owner and Contractor may otherwise agree in writing. 6.19 Contractor's General Warranty and Guarantee A. Contractor warrants and guarantees to Owner that all Work will be in accordance with the Contract Documents and will not be defective. Engineer and its officers, directors, members, partners, employees, agents, consultants, and subcontractors shall be entitled to rely on representation of Contractor's warranty and guarantee. B. Contractor's warranty and guarantee hereunder excludes defects or damage caused by: 1. abuse, modification, or improper maintenance or operation by persons other than Contractor, Subcontractors, Suppliers, or any other individual or entity for whom Contractor is responsible; or 2. normal wear and tear- under normal usage. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 35 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT C. Contractor's obligation to perform and complete the Work in accordance with the Con- tract Documents shall be absolute. None of the following will constitute an acceptance of Work that is not in accordance with the Contract Documents or a release of Contrac- tor's obligation to perform the Work in accordance with the Contract Documents: 1. observations by Engineer; 2. recommendation by Engineer or payment by Owner of any progress or final pay- ment; 3. the issuance of a certificate of Substantial Completion by Engineer or any payment related thereto by Owner; 4. use or occupancy of the Work or any part thereof by Owner; 5. any review and approval of a Shop Drawing or Sample submittal or the issuance of a notice of acceptability by Engineer; 6. any inspection, test, or approval by others; or 7. any correction of defective Work by Owner. 6.20 Indemnification A. To the fullest extent permitted by Laws and Regulations, Contractor shall indemnify and hold harmless Owner and Engineer, and the officers, directors, members, partners, employees, agents, consultants and subcontractors of each and any of them from and against all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbi- tration or other dispute resolution costs) arising out of or relating to the performance of the Work, provided that any such claim, cost, loss, or damage is attributable to bodily injury, sickness, disease, or death, or to injury to or destruction of tangible property (other than the Work itself), including the loss of use resulting therefrom but only to the extent caused by any negligent act or omission of Contractor, any Subcontractor, any Supplier, or any individual or entity directly or indirectly employed by any of them to perform any of the Work or anyone for whose acts any of them may be liable. B. In any and all claims against Owner or Engineer or any of their officers, directors, members, partners, employees, agents, consultants, or subcontractors by any employee (or the survivor or personal representative of such employee) of Contractor, any Sub- contractor, any Supplier, or any individual or entity directly or indirectly employed by any of them to perform any of the Work, or anyone for whose acts any of them may be liable, the indemnification obligation under Paragraph 6.20.A shall not be limited in any way by any limitation on the amount or type of damages, compensation, or benefits payable by or for Contractor or any such Subcontractor, Supplier, or other individual or entity under workers' compensation acts, disability benefit acts, or other employee benefit acts. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright D 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 36 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA STANDARD CONDITIONS OF THE CONSTRUCTION CONTRACT C. The indemnification obligations of Contractor- under Paragraph 6.20.A shall not extend to the liability of Engineer and Engineer's officers, directors, members, partners, em- ployees, agents, consultants and subcontractors arising out of: 1. the preparation or approval of, or the failure to prepare or approve maps, Drawings, opinions, reports, surveys, Change Orders, designs, or Specifications; or 2. giving directions or instructions, or failing to give them, if that is the primary cause of the injury or damage. 6.21 Delegation of Professional Design Services A. Contractor will not be required to provide professional design services unless such ser- vices are specifically required by the Contract Documents for a portion of the Work or unless such services are required to carry out Contractor's responsibilities for construc- tion means, methods, techniques, sequences and procedures. Contractor shall not be required to provide professional services in violation of applicable law. B. If professional design services or certifications by a design professional related to sys- tems, materials or equipment are specifically required of Contractor by the Contract Documents, Owner and Engineer will specify all performance and design criteria that such services must satisfy. Contractor shall cause such services or certifications to be provided by a properly licensed professional, whose signature and seal shall appear on all drawings, calculations, specifications, certifications, Shop Drawings and other sub- mittals prepared by such professional. Shop Drawings and other submittals related to the Work designed or certified by such professional, if prepared by others, shall bear such professional's written approval when submitted to Engineer. C. Owner and Engineer shall be entitled to rely upon the adequacy, accuracy and com- pleteness of the services, certifications or approvals performed by such design profes- sionals, provided Owner and Engineer have specified to Contractor all performance and design criteria that such services must satisfy. D. Pursuant to this Paragraph 6.21, Engineer's review and approval of design calculations and design drawings will be only for the limited purpose of checking for conformance with performance and design criteria given and the design concept expressed in the Contract Documents. Engineer's review and approval of Shop Drawings and other submittals (except design calculations and design drawings) will be only for the pur- pose stated in Paragraph 6.17.D.1. E. Contractor shall not be responsible for the adequacy of the performance or design crite- ria required by the Contract Documents. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 37 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT ARTICLE 7 — OTHER WORK AT THE SITE 7.01 Related Work at Site A. Owner may perform other work related to the Project at the Site with Owner's employ- ees, or through other direct contracts therefor, or have other work performed by utility owners. If such other work is not noted in the Contract Documents, then: 1. written notice thereof will be given to Contractor prior to starting any such other work; and 2. if Owner and Contractor are unable to agree on entitlement to or on the amount or extent, if any, of any adjustment in the Contract Price or Contract Times that should be allowed as a result of such other work, a Claim may be made therefor as pro- vided in Paragraph 10.05. B. Contractor shall afford each other contractor who is a party to such a direct contract, each utility owner, and Owner, if Owner is performing other work with Owner's em- ployees, proper and safe access to the Site, provide a reasonable opportunity for the in- troduction and storage of materials and equipment and the execution of such other work, and properly coordinate the Work with theirs. Contractor shall do all cutting, fit- ting, and patching of the Work that may be required to properly connect or otherwise make its several parts come together and properly integrate with such other work. Con- tractor shall not endanger any work of others by cutting, excavating, or otherwise alter- ing such work; provided, however, that Contractor may cut or alter others' work with the written consent of Engineer and the others whose work will be affected. The duties and responsibilities of Contractor under this Paragraph are for the benefit of such utility owners and other contractors to the extent that there are comparable provisions for the benefit of Contractor in said direct contracts between Owner and such utility owners and other contractors. C. If the proper execution or results of any part of Contractor's Work depends upon work performed by others under this Article 7, Contractor shall inspect such other work and promptly report to Engineer in writing any delays, defects, or deficiencies in such other work that render it unavailable or unsuitable for the proper execution and results of Contractor's Work. Contractor's failure to so report will constitute an acceptance of such other work as fit and proper for integration with Contractor's Work except for la- tent defects and deficiencies in such other work. 7.02 Coordination A. If Owner intends to contract with others for the performance of other work on the Pro- ject at the Site, the following will be set forth in Supplementary Conditions: 1. the individual or entity who will have authority and responsibility for coordination of the activities among the various contractors will be identified; EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 38 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 2. the specific matters to be covered by such authority and responsibility will be item- ized; and 3. the extent of such authority and responsibilities will be provided. B. Unless otherwise provided in the Supplementary Conditions, Owner shall have sole au- thority and responsibility for such coordination. 7.03 Legal Relationships A. Paragraphs 7.01.A and 7.02 are not applicable for utilities not under the control of Owner. B. Each other direct contract of Owner under Paragraph TOLA shall provide that the other contractor is liable to Owner and Contractor for the reasonable direct delay and disnrp- tion costs incurred by Contractor as a result of the other contractor's wrongful actions or inactions. C. Contractor shall be liable to Owner and any other contractor under direct contract to Owner for the reasonable direct delay and disruption costs incurred by such other con- tractor as a result of Contractor's wrongful action or inactions. ARTICLE 8 — OWNER'S RESPONSIBILITIES 8.01 Communications to Contractor A. Except as otherwise provided in these General Conditions, Owner shall issue all com- munications to Contractor through Engineer. 8.02 Replacement of Engineer A. In case of termination of the employment of Engineer, Owner shall appoint an engineer to whom Contractor makes no reasonable objection, whose status under the Contract Documents shall be that of the former Engineer. 8.03 Furnish Data A. Owner shall promptly furnish the data required of Owner under the Contract Docu- ments. 8.04 Pay When Due A. Owner shall make payments to Contractor when they are due as provided in Paragraphs 14.02.0 and 14.07.C. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright ® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 39 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 8.05 Lands and Easements; Reports and Tests A. Owner's duties with respect to providing lands and easements and providing engineer- ing surveys to establish reference points are set forth in Paragraphs 4.01 and 4.05. Paragraph 4.02 refers to Owner's identifying and making available to Contractor copies of reports of explorations and tests of subsurface conditions and drawings of physical conditions relating to existing surface or subsurface structures at the Site. 8.06 Insurance A. Owner's responsibilities, if any, with respect to purchasing and maintaining liability and property insurance are set forth in Article 5. 8.07 Change Orders A. Owner is obligated to execute Change Orders as indicated in Paragraph 10.03. 8.08 Inspections, Tests, and Approvals A. Owner's responsibility with respect to certain inspections, tests, and approvals is set forth in Paragraph 13.03.13. 8.09 Litnitations on Owner's Responsibilities A. The Owner shall not supervise, direct, or have control or authority over, nor be respon- sible for, Contractor's means, methods, techniques, sequences, or procedures of con- struction, or the safety precautions and programs incident thereto, or for any failure of Contractor to comply with Laws and Regulations applicable to the performance of the Work. Owner will not be responsible for Contractor's failure to perform the Work in accordance with the Contract Documents. 8.10 Undisclosed Hazardous Environmental Condition A. Owner's responsibility in respect to an undisclosed Hazardous Environmental Condi- tion is set forth in Paragraph 4.06. 8.11 Evidence of Financial Arrangements A. Upon request of Contractor, Owner shall furnish Contractor reasonable evidence that financial arrangements have been made to satisfy Owner's obligations under the Con- tract Documents. 8.12 Compliance with Safety Program A. While at the Site, Owner's employees and representatives shall comply with the spe- cific applicable requirements of Contractor's safety programs of which Owner has been informed pursuant to Paragraph 6.13.D. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 40 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT ARTICLE 9 — ENGINEER'S STATUS DURING CONSTRUCTION 9.01 Owner's Representative A. Engineer will be Owner's representative during the construction period. The duties and responsibilities and the limitations of authority of Engineer as Owner's representative during construction are set forth in the Contract Documents. 9.02 Visits to Site A. Engineer will make visits to the Site at intervals appropriate to the various stages of construction as Engineer deems necessary in order to observe as an experienced and qualified design professional the progress that has been made and the quality of the various aspects of Contractor's executed Work. Based on information obtained during such visits and observations, Engineer, for the benefit of Owner, will determine, in gen- eral, if the Work is proceeding in accordance with the Contract Documents. Engineer will not be required to make exhaustive or continuous inspections on the Site to check the quality or quantity of the Work. Engineer's efforts will be directed toward provid- ing for Owner a greater degree of confidence that the completed Work will conform generally to the Contract Documents. On the basis of such visits and observations, En- gineer will keep Owner informed of the progress of the Work and will endeavor to guard Owner against defective Work. B. Engineer's visits and observations are subject to all the limitations on Engineer's au- thority and responsibility set forth in Paragraph 9.09. Particularly, but without limita- tion, during or as a result of Engineer's visits or observations of Contractor's Work, Engineer will not supervise, direct, control, or have authority over or be responsible for Contractor's means, methods, techniques, sequences, or procedures of construction, or the safety precautions and programs incident thereto, or for any failure of Contractor to comply with Laws and Regulations applicable to the performance of the Work. 9.03 Project Representative A. If Owner and Engineer agree, Engineer will furnish a Resident Project Representative to assist Engineer in providing more extensive observation of the Work. The authority and responsibilities of any such Resident Project Representative and assistants will be as provided in the Supplementary Conditions, and limitations on the responsibilities thereof will be as provided in Paragraph 9.09. If Owner designates another representa- tive or agent to represent Owner at the Site who is not Engineer's consultant, agent or employee, the responsibilities and authority and limitations thereon of such other indi- vidual or entity will be as provided in the Supplementary Conditions. 9.04 Authorized Variations in Work A. Engineer may authorize minor variations in the Work from the requirements of the Contract Documents which do not involve an adjustment in the Contract Price or the Contract Times and are compatible with the design concept of the completed Project as EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 41 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT a functioning whole as indicated by the Contract Documents. These may be accom- plished by a Field Order and will be binding on Owner and also on Contractor, who shall perform the Work involved promptly. If Owner or Contractor believes that a Field Order justifies an adjustment in the Contract Price or Contract Times, or both, and the parties are unable to agree on entitlement to or on the amount or extent, if any, of any such adjustment, a Claim may be made therefor as provided in Paragraph 10.05. 9.05 Rejecting Defective Work A. Engineer will have authority to reject Work which Engineer believes to be defective, or that Engineer believes will not produce a completed Project that conforms to the Con- tract Documents or that will prejudice the integrity of the design concept of the com- pleted Project as a functioning whole as indicated by the Contract Documents. Engi- neer will also have authority to require special inspection or testing of the Work as pro- vided in Paragraph 13.04, whether or not the Work is fabricated, installed, or com- pleted. 9.06 Shop Drawings, Change Orders and Payments A. In connection with Engineer's authority, and limitations thereof, as to Shop Drawings and Samples, see Paragraph 6.17. B. In connection with Engineer's authority, and limitations thereof, as to design calcula- tions and design drawings submitted in response to a delegation of professional design services, if any, see Paragraph 6.21. C. In connection with Engineer's authority as to Change Orders, see Articles 10, 11, and 12. D. In connection with Engineer's authority as to Applications for Payment, see Article 14. 9.07 Deternlinationsfor Unit Price Work A. Engineer will determine the actual quantities and classifications of Unit Price Work performed by Contractor. Engineer will review with Contractor the Engineer's pre- liminary determinations on such matters before rendering a written decision thereon (by recommendation of an Application for Payment or otherwise). Engineer's written deci- sion thereon will be final and binding (except as modified by Engineer to reflect changed factual conditions or more accurate data) upon Owner and Contractor, subject to the provisions of Paragraph 10.05. 9.08 Decisions on Requirements of Contract Documents and Acceptability of Work A. Engineer will be the initial interpreter of the requirements of the Contract Documents and judge of the acceptability of the Work thereunder. All matters in question and other matters between Owner and Contractor arising prior to the date final payment is due relating to the acceptability of the Work, and the interpretation of the requirements EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 42 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT of the Contract Documents pertaining to the performance of the Work, will be referred initially to Engineer in writing within 30 days of the event giving rise to the question. B. Engineer will, with reasonable promptness, render a written decision on the issue re- ferred. If Owner or Contractor believes that any such decision entitles them to an ad- justment in the Contract Price or Contract Times or both, a Claim may be made under Paragraph 10.05. The date of Engineer's decision shall be the date of the event giving rise to the issues referenced for the purposes of Paragraph 10.05.13. C. Engineer's written decision on the issue referred will be final and binding on Owner and Contractor, subject to the provisions of Paragraph 10.05. D. When functioning as interpreter and judge under this Paragraph 9.08, Engineer will not show partiality to Owner or Contractor and will not be liable in connection with any in- terpretation or decision rendered in good faith in such capacity. 9.09 Limitations on Engineer's Authority and Responsibilities A. Neither Engineer's authority or responsibility under this Article 9 or under any other provision of the Contract Documents nor any decision made by Engineer in good faith either to exercise or not exercise such authority or responsibility or the undertaking, ex- ercise, or performance of any authority or responsibility by Engineer shall create, im- pose, or give rise to any duty in contract, tort, or otherwise owed by Engineer to Con- tractor, any Subcontractor, any Supplier, any other individual or entity, or to any surety for or employee or agent of any of them. B. Engineer will not supervise, direct, control, or have authority over or be responsible for Contractor's means, methods, techniques, sequences, or procedures of construction, or the safety precautions and programs incident thereto, or for any failure of Contractor to comply with Laws and Regulations applicable to the performance of the Work. Engi- neer will not be responsible for Contractor's failure to perform the Work in accordance with the Contract Documents. C. Engineer will not be responsible for the acts or omissions of Contractor or of any Sub- contractor, any Supplier, or of any other individual or entity performing any of the Work. D. Engineer's review of the final Application for Payment and accompanying documenta- tion and all maintenance and operating instructions, schedules, guarantees, bonds, cer- tificates of inspection, tests and approvals, and other documentation required to be de- livered by Paragraph 14.07.A will only be to determine generally that their content complies with the requirements of, and in the case of certificates of inspections, tests, and approvals that the results certified indicate compliance with, the Contract Docu- ments. E. The limitations upon authority and responsibility set forth in this Paragraph 9.09 shall also apply to the Resident Project Representative, if any, and assistants, if any. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 43 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 9.10 Compliance with Safety Program A. While at the Site, Engineer's employees and representatives shall comply with the spe- cific applicable requirements of Contractor's safety programs of which Engineer has been informed pursuant to Paragraph 6.13.D. ARTICLE 10 — CHANGES IN THE WORK; CLAIMS 10.01 Authorized Changes in the Work A. Without invalidating the Contract and without notice to any surety, Owner may, at any time or from time to time, order additions, deletions, or revisions in the Work by a Change Order, or a Work Change Directive. Upon receipt of any such document, Con- tractor shall promptly proceed with the Work involved which will be performed under the applicable conditions of the Contract Documents (except as otherwise specifically provided). B. If Owner and Contractor are unable to agree on entitlement to, or on the amount or ex- tent, if any, of an adjustment in the Contract Price or Contract Times, or both, that should be allowed as a result of a Work Change Directive, a Claim may be made there- for as provided in Paragraph 10.05. 10.02 Unauthorized Changes in the Work A. Contractor shall not be entitled to an increase in the Contract Price or an extension of the Contract Times with respect to any work performed that is not required by the Con- tract Documents as amended, modified, or supplemented as provided in Paragraph 3.04, except in the case of an emergency as provided in Paragraph 6.16 or in the case of uncovering Work as provided in Paragraph 13.04.D. 10.03 Execution of Change Orders A. Owner and Contractor shall execute appropriate Change Orders recommended by En- gineer covering: 1. changes in the Work which are: (i) ordered by Owner pursuant to Paragraph 10.0l.A, (ii) required because of acceptance of defective Work under Paragraph 13.08.A or Owner's correction of defective Work under Paragraph 13.09, or (iii) agreed to by the parties; 2. changes in the Contract Price or Contract Times which are agreed to by the parties, including any undisputed sum or amount of time for Work actually performed in accordance with a Work Change Directive; and changes in the Contract Price or Contract Times which embody the substance of any written decision rendered by Engineer pursuant to Paragraph 10.05; provided that, in lieu of executing any such Change Order, an appeal may be taken from any such decision in accordance with the provisions of the Contract Documents and ap- EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 44 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT plicable Laws and Regulations, but during any such appeal, Contractor shall carry on the Work and adhere to the Progress Schedule as provided in Paragraph 6.18.A. 10.04 Notification to Surety A. If the provisions of any bond require notice to be given to a surety of any change affect- ing the general scope of the Work or the provisions of the Contract Documents (includ- ing, but not limited to, Contract Price or Contract Times), the giving of any such notice will be Contractor's responsibility. The amount of each applicable bond will be ad- justed to reflect the effect of any such change. 10.05 Claims A. Engineer's Decision Required: All Claims, except those waived pursuant to Paragraph 14.09, shall be referred to the Engineer for decision. A decision by Engineer shall be required as a condition precedent to any exercise by Owner or Contractor of any rights or remedies either may otherwise have under the Contract Documents or by Laws and Regulations in respect of such Claims. B. Notice: Written notice stating the general nature of each Claim shall be delivered by the claimant to Engineer and the other party to the Contract promptly (but in no event later than 30 days) after the start of the event giving rise thereto. The responsibility to sub- stantiate a Claim shall rest with the party making the Claim. Notice of the amount or extent of the Claim, with supporting data shall be delivered to the Engineer and the other party to the Contract within 60 days after the start of such event (unless Engineer allows additional time for claimant to submit additional or more accurate data in sup- port of such Claim). A Claim for an adjustment in Contract Price shall be prepared in accordance with the provisions of Paragraph 12.01.13. A Claim for an adjustment in Contract Times shall be prepared in accordance with the provisions of Paragraph 12.02.B. Each Claim shall be accompanied by claimant's written statement that the ad- justment claimed is the entire adjustment to which the claimant believes it is entitled as a result of said event. The opposing party shall submit any response to Engineer and the claimant within 30 days after receipt of the claimant's last submittal (unless Engi- neer allows additional time). C. Engineer's Action: Engineer will review each Claim and, within 30 days after receipt of the last submittal of the claimant or the last submittal of the opposing party, if any, take one of the following actions in writing: 1. deny the Claim in whole or in part; 2. approve the Claim; or 3. notify the parties that the Engineer is unable to resolve the Claim if, in the Engi- neer's sole discretion, it would be inappropriate for the Engineer to do so. For pur- poses of further resolution of the Claim, such notice shall be deemed a denial. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 45 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT D. In the event that Engineer does not take action on a Claim within said 30 days, the Claim shall be deemed denied. E. Engineer's written action under Paragraph 10.05.0 or denial pursuant to Paragraphs 10.05.C.3 or 10.05.13 will be final and binding upon Owner and Contractor, unless Owner or Contractor invoke the dispute resolution procedure set forth in Article 16 within 30 days of such action or denial. F. No Claim for an adjustment in Contract Price or Contract Times will be valid if not submitted in accordance with this Paragraph 10.05. ARTICLE 11— COST OF THE WORK; ALLOWANCES; UNIT PRICE WORK 11.01 Cost of the Work A. Costs Included: The term Cost of the Work means the sum of all costs, except those excluded in Paragraph 11.01.13, necessarily incurred and paid by Contractor in the proper performance of the Work. When the value of any Work covered by a Change Order or when a Claim for an adjustment in Contract Price is determined on the basis of Cost of the Work, the costs to be reimbursed to Contractor will be only those additional or incremental costs required because of the change in the Work or because of the event giving rise to the Claim. Except as otherwise may be agreed to in writing by Owner, such costs shall be in amounts no higher than those prevailing in the locality of the Pro- ject, shall not include any of the costs itemized in Paragraph 11.01.13, and shall include only the following items: 1. Payroll costs for employees in the direct employ of Contractor in the performance of the Work under schedules of job classifications agreed upon by Owner and Con- tractor. Such employees shall include, without limitation, superintendents, fore- men, and other personnel employed full time on the Work. Payroll costs for em- ployees not employed full time on the Work shall be apportioned on the basis of their time spent on the Work. Payroll costs shall include, but not be limited to, sala- ries and wages plus the cost of fringe benefits, which shall include social security contributions, unemployment, excise, and payroll taxes, workers' compensation, health and retirement benefits, bonuses, sick leave, vacation and holiday pay appli- cable thereto. The expenses of performing Work outside of regular working hours, on Saturday, Sunday, or legal holidays, shall be included in the above to the extent authorized by Owner. 2. Cost of all materials and equipment furnished and incorporated in the Work, includ- ing costs of transportation and storage thereof, and Suppliers' field services re- quired in connection therewith. All cash discounts shall accrue to Contractor unless Owner deposits funds with Contractor with which to make payments, in which case the cash discounts shall accrue to Owner. All trade discounts, rebates and refunds and returns from sale of surplus materials and equipment shall accrue to Owner, and Contractor shall make provisions so that they may be obtained. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 46 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 3. Payments made by Contractor to Subcontractors for Work performed by Subcon- tractors. If required by Owner, Contractor shall obtain competitive bids from sub- contractors acceptable to Owner and Contractor and shall deliver such bids to Owner, who will then determine, with the advice of Engineer, which bids, if any, will be acceptable. If any subcontract provides that the Subcontractor is to be paid on the basis of Cost of the Work plus a fee, the Subcontractor's Cost of the Work and fee shall be determined in the same manner as Contractor's Cost of the Work and fee as provided in this Paragraph 11.01. 4. Costs of special consultants (including but not limited to engineers, architects, test- ing laboratories, surveyors, attorneys, and accountants) employed for services spe- cifically related to the Work. 5. Supplemental costs including the following: a. The proportion of necessary transportation, travel, and subsistence expenses of Contractor's employees incurred in discharge of dirties connected with the Work. b. Cost, including transportation and maintenance, of all materials, supplies, equipment, machinery, appliances, office, and temporary facilities at the Site, and hand tools not owned by the workers, which are consumed in the perform- ance of the Work, and cost, less market value, of such items used but not con- sumed which remain the property of Contractor. c. Rentals of all construction equipment and machinery, and the parts thereof whether rented from Contractor or others in accordance with rental agreements approved by Owner with the advice of Engineer, and the costs of transportation, loading, unloading, assembly, dismantling, and removal thereof. All such costs shall be in accordance with the terms of said rental agreements. The rental of any such equipment, machinery, or parts shall cease when the use thereof is no longer necessary for the Work. d. Sales, consumer, use, and other similar taxes related to the Work, and for which Contractor is liable, as imposed by Laws and Regulations. e. Deposits lost for causes other than negligence of Contractor, any Subcontractor, or anyone directly or indirectly employed by any of them or for whose acts any of them may be liable, and royalty payments and fees for permits and licenses. f. Losses and damages (and related expenses) caused by damage to the Work, not compensated by insurance or otherwise, sustained by Contractor in connection with the performance of the Work (except losses and damages within the de- ductible amounts of property insurance established in accordance with Para- graph 5.06.D), provided such losses and damages have resulted from causes other than the negligence of Contractor, any Subcontractor, or anyone directly or indirectly employed by any of them or for whose acts any of them may be li- EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 47 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT able. Such losses shall include settlements made with the written consent and approval of Owner. No such losses, damages, and expenses shall be included in the Cost of the Work for the purpose of determining Contractor's fee. g. The cost of utilities, fuel, and sanitary facilities at the Site. h. Minor expenses such as telegrams, long distance telephone calls, telephone ser- vice at the Site, express and courier services, and similar petty cash items in connection with the Work. The costs of premiums for all bonds and insurance Contractor is required by the Contract Documents to purchase and maintain. B. Costs Excluded: The term Cost of the Work shall not include any of the following items: Payroll costs and other compensation of Contractor's officers, executives, princi- pals (of partnerships and sole proprietorships), general managers, safety managers, engineers, architects, estimators, attorneys, auditors, accountants, purchasing and contracting agents, expediters, timekeepers, clerks, and other personnel employed by Contractor, whether at the Site or in Contractor's principal or branch office for general administration of the Work and not specifically included in the agreed upon schedule of job classifications referred to in Paragraph 11.01.A.1 or specifically covered by Paragraph 11.0I.A.4, all of which are to be considered administrative costs covered by the Contractor's fee. 2. Expenses of Contractor's principal and branch offices other than Contractor's office at the Site. 3. Any part of Contractor's capital expenses, including interest on Contractor's capital employed for the Work and charges against Contractor for delinquent payments. 4. Costs due to the negligence of Contractor, any Subcontractor, or anyone directly or indirectly employed by any of them or for whose acts any of them may be liable, including but not limited to, the correction of defective Work, disposal of materials or equipment wrongly supplied, and making good any damage to property. Other overhead or general expense costs of any kind and the costs of any item not specifically and expressly included in Paragraphs 11.01.A. C. Contractor's Fee: When all the Work is performed on the basis of cost-plus, Contrac- tor's fee shall be determined as set forth in the Agreement. When the value of any Work covered by a Change Order- or when a Claim for an adjustment in Contract Price is determined on the basis of Cost of the Work, Contractor's fee shall be determined as set forth in Paragraph 12.01.C. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 48 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT D. Documentation: Whenever the Cost of the Work for any purpose is to be determined pursuant to Paragraphs I LOLA and 11.01.13, Contractor will establish and maintain re- cords thereof in accordance with generally accepted accounting practices and submit in a form acceptable to Engineer an itemized cost breakdown together with supporting data. 11.02 Allowances A. It is understood that Contractor has included in the Contract Price all allowances so named in the Contract Documents and shall cause the Work so covered to be performed for such sums and by such persons or entities as may be acceptable to Owner and Engi- neer. B. Cash Allowances: 1. Contractor agrees that: a. the cash allowances include the cost to Contractor (less any applicable trade discounts) of materials and equipment required by the allowances to be deliv- ered at the Site, and all applicable taxes; and b. Contractor's costs for unloading and handling on the Site, labor, installation, overhead, profit, and other expenses contemplated for the cash allowances have been included in the Contract Price and not in the allowances, and no demand for additional payment on account of any of the foregoing will be valid. C. Contingency Allowance: 1. Contractor agrees that a contingency allowance, if any, is for the sole use of Owner to cover unanticipated costs. D. Prior to final payment, an appropriate Change Order will be issued as recommended by Engineer to reflect actual amounts due Contractor on account of Work covered by al- lowances, and the Contract Price shall be correspondingly adjusted. 11.03 Unit Price Work A. Where the Contract Documents provide that all or part of the Work is to be Unit Price Work, initially the Contract Price will be deemed to include for all Unit Price Work an amount equal to the sum of the unit price for each separately identified item of Unit Price Work times the estimated quantity of each item as indicated in the Agreement. B. The estimated quantities of items of Unit Price Work are not guaranteed and are solely for the purpose of comparison of Bids and determining an initial Contract Price. De- terminations of the actual quantities and classifications of Unit Price Work performed by Contractor will be made by Engineer subject to the provisions of Paragraph 9.07. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 49 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT C. Each unit price will be deemed to include an amount considered by Contractor to be adequate to cover Contractor's overhead and profit for each separately identified item. D. Owner or Contractor may make a Claim for an adjustment in the Contract Price in ac- cordance with Paragraph 10.05 if: 1. the quantity of any item of Unit Price Work performed by Contractor differs mate- rially and significantly from the estimated quantity of such item indicated in the Agreement; and 2. there is no corresponding adjustment with respect to any other item of Work; and 3. Contractor believes that Contractor is entitled to an increase in Contract Price as a result of having incurred additional expense or Owner believes that Owner is enti- tled to a decrease in Contract Price and the parties are unable to agree as to the amount of any such increase or decrease. ARTICLE 12 — CHANGE OF CONTRACT PRICE; CHANGE OF CONTRACT TIMES 12.01 Change of Contract Price A. The Contract Price may only be changed by a Change Order. Any Claim for an ad- justment in the Contract Price shall be based on written notice submitted by the party making the Claim to the Engineer and the other party to the Contract in accordance with the provisions of Paragraph 10.05. B. The value of any Work covered by a Change Order or of any Claim for an adjustment in the Contract Price will be determined as follows: 1. where the Work involved is covered by unit prices contained in the Contract Documents, by application of such unit prices to the quantities of the items in- volved (subject to the provisions of Paragraph 11.03); or 2. where the Work involved is not covered by unit prices contained in the Contract Documents, by a mutually agreed lump sum (which may include an allowance for overhead and profit not necessarily in accordance with Paragraph 12.0l.C.2); or 3. where the Work involved is not covered by unit prices contained in the Contract Documents and agreement to a lump sum is not reached under Paragraph 12.0I.B.2, on the basis of the Cost of the Work (determined as provided in Paragraph 11.01) plus a Contractor's fee for overhead and profit (determined as provided in Para- graph 12.01.Q. C. Contractor's Fee: The Contractor's fee for overhead and profit shall be determined as follows: 1. a mutually acceptable fixed fee; or EJCDC C•700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 50 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 2. if a fixed fee is not agreed upon, then a fee based on the following percentages of the various portions of the Cost of the Work: a. for costs incurred under Paragraphs 11.0l.A.1 and I1.0l.A.2, the Contractor's fee shall be 15 percent; b. for costs incurred under Paragraph 11.0l.A.3, the Contractor's fee shall be five percent; c. where one or more tiers of subcontracts are on the basis of Cost of the Work plus a fee and no fixed fee is agreed upon, the intent of Paragraphs 12.0l.C.2.a and 12.0l.C.2.b is that the Subcontractor who actually performs the Work, at whatever tier, will be paid a fee of 15 percent of the costs incurred by such Sub- contractor under Paragraphs I1.0I.A.I and I1.0l.A.2 and that any higher tier Subcontractor and Contractor will each be paid a fee of five percent of the amount paid to the next lower tier Subcontractor; d. no fee shall be payable on the basis of costs itemized under Paragraphs 11.0l.A.4, I1.0l.A.5, and 11.01.13; e. the amount of credit to be allowed by Contractor to Owner for any change which results in a net decrease in cost will be the amount of the actual net de- crease in cost plus a deduction in Contractor's fee by an amount equal to five percent of such net decrease; and f. when both additions and credits are involved in any one change, the adjustment in Contractor's fee shall be computed on the basis of the net change in accor- dance with Paragraphs 12.0l.C.2.a through 12.01.C.2.e, inclusive. 12.02 Change of Contract Times A. The Contract Times may only be changed by a Change Order. Any Claim for an ad- justment in the Contract Times shall be based on written notice submitted by the party making the Claim to the Engineer and the other party to the Contract in accordance with the provisions of Paragraph 10.05. B. Any adjustment of the Contract Times covered by a Change Order or any Claim for an adjustment in the Contract Times will be determined in accordance with the provisions of this Article 12. 12.03 Delays A. Where Contractor is prevented from completing any part of the Work within the Con- tract Times due to delay beyond the control of Contractor, the Contract Times will be extended in an amount equal to the time lost due to such delay if a Claim is made there- for as provided in Paragraph 12.02.A. Delays beyond the control of Contractor shall include, but not be limited to, acts or neglect by Owner, acts or neglect of utility owners EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 51 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT or other contractors performing other work as contemplated by Article 7, fires, floods, epidemics, abnormal weather conditions, or acts of God. B. If Owner, Engineer, or other contractors or utility owners performing other work for Owner as contemplated by Article 7, or anyone for whom Owner is responsible, delays, disrupts, or interferes with the performance or progress of the Work, then Contractor shall be entitled to an equitable adjustment in the Contract Price or the Contract Times, or both. Contractor's entitlement to an adjustment of the Contract Times is conditioned on such adjustment being essential to Contractor's ability to complete the Work within the Contract Times. C. If Contractor is delayed in the performance or progress of the Work by fire, flood, epi- demic, abnormal weather conditions, acts of God, acts or failures to act of utility own- ers not under the control of Owner, or other causes not the fault of and beyond control of Owner and Contractor, then Contractor shall be entitled to an equitable adjustment in Contract Times, if such adjustment is essential to Contractor's ability to complete the Work within the Contract Times. Such an adjustment shall be Contractor's sole and exclusive remedy for the delays described in this Paragraph 12.03.C. D. Owner, Engineer, and their officers, directors, members, partners, employees, agents, consultants, or subcontractors shall not be liable to Contractor for any claims, costs, losses, or damages (including but not limited to all fees and charges of engineers, archi- tects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) sustained by Contractor on or in connection with any other project or anticipated project. E. Contractor shall not be entitled to an adjustment in Contract Price or Contract Times for delays within the control of Contractor. Delays attributable to and within the control of a Subcontractor or Supplier shall be deemed to be delays within the control of Contrac- tor. ARTICLE 13 — TESTS AND INSPECTIONS; CORRECTION, REMOVAL OR ACCEPTANCE OF DEFECTIVE WORK 13.01 Notice of Defects A. Prompt notice of all defective Work of which Owner or Engineer has actual knowledge will be given to Contractor. Defective Work may be rejected, corrected, or accepted as provided in this Article 13. 13.02 Access to Work A. Owner, Engineer, their consultants and other representatives and personnel of Owner, independent testing laboratories, and governmental agencies with jurisdictional inter- ests will have access to the Site and the Work at reasonable times for their observation, inspection, and testing. Contractor shall provide them proper and safe conditions for EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 52 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT such access and advise them of Contractor's safety procedures and programs so that they may comply therewith as applicable. 13.03 Tests and Inspections A. Contractor shall give Engineer timely notice of readiness of the Work for all required inspections, tests, or approvals and shall cooperate with inspection and testing person- nel to facilitate required inspections or tests. B. Owner shall employ and pay for the services of an independent testing laboratory to perform all inspections, tests, or approvals required by the Contract Documents except: 1. for inspections, tests, or approvals covered by Paragraphs 13.03.0 and 13.03.1) be- low; 2. that costs incurred in connection with tests or inspections conducted pursuant to Paragraph 13.04.B shall be paid as provided in Paragraph 13.04.C; and 3. as otherwise specifically provided in the Contract Documents. C. If Laws or Regulations of any public body having jurisdiction require any Work (or part thereof) specifically to be inspected, tested, or approved by an employee or other representative of such public body, Contractor shall assume full responsibility for ar- ranging and obtaining such inspections, tests, or approvals, pay all costs in connection therewith, and furnish Engineer the required certificates of inspection or approval. D. Contractor shall be responsible for arranging and obtaining and shall pay all costs in connection with any inspections, tests, or approvals required for Owner's and Engi- neer's acceptance of materials or equipment to be incorporated in the Work; or accep- tance of materials, mix designs, or equipment submitted for approval prior to Contrac- tor's purchase thereof for incorporation in the Work. Such inspections, tests, or ap- provals shall be performed by organizations acceptable to Owner and Engineer. E. If any Work (or the work of others) that is to be inspected, tested, or approved is cov- ered by Contractor without written concurrence of Engineer, Contractor shall, if re- quested by Engineer, uncover such Work for observation. F. Uncovering Work as provided in Paragraph 13.03.E shall be at Contractor's expense unless Contractor has given Engineer- timely notice of Contractor's intention to cover the same and Engineer has not acted with reasonable promptness in response to such notice. 13.04 Uncovering Work A. If any Work is covered contrary to the written request of Engineer, it must, if requested by Engineer, be uncovered for Engineer's observation and replaced at Contractor's ex- pense. E7CDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for ESCDC. All rights reserved. Page 53 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT B. If Engineer considers it necessary or advisable that covered Work be observed by En- gineer or inspected or tested by others, Contractor, at Engineer's request, shall uncover, expose, or otherwise make available for observation, inspection, or testing as Engineer may require, that portion of the Work in question, furnishing all necessary labor, mate- rial, and equipment. C. If it is found that the uncovered Work is defective, Contractor shall pay all claims, costs, losses, and damages (including but not limited to all fees and charges of engi- neers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) arising out of or relating to such uncovering, exposure, obser- vation, inspection, and testing, and of satisfactory replacement or reconstruction (in- cluding but not limited to all costs of repair or replacement of work of others); and Owner shall be entitled to an appropriate decrease in the Contract Price. If the parties are unable to agree as to the amount thereof, Owner may make a Claim therefor as pro- vided in Paragraph 10.05. D. If the uncovered Work is not found to be defective, Contractor shall be allowed an in- crease in the Contract Price or an extension of the Contract Times, or both, directly at- tributable to such uncovering, exposure, observation, inspection, testing, replacement, and reconstruction. If the parties are unable to agree as to the amount or extent thereof, Contractor may make a Claim therefor as provided in Paragraph 10.05. 13.05 Owner May Stop the Work A. If the Work is defective, or Contractor fails to supply sufficient skilled workers or suit- able materials or equipment, or fails to perform the Work in such a way that the com- pleted Work will conform to the Contract Documents, Owner may order Contractor to stop the Work, or any portion thereof, until the cause for such order has been elimi- nated; however, this right of Owner to stop the Work shall not give rise to any duty on the part of Owner to exercise this right for the benefit of Contractor, any Subcontractor, any Supplier, any other individual or entity, or any surety for, or employee or agent of any of them. 13.06 Correction or Removal of Defective Work A. Promptly after receipt of written notice, Contractor shall correct all defective Work, whether or not fabricated, installed, or completed, or, if the Work has been rejected by Engineer, remove it from the Project and replace it with Work that is not defective. Contractor shall pay all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) arising out of or relating to such correction or removal (including but not limited to all costs of repair or replacement of work of others). B. When correcting defective Work under the terms of this Paragraph 13.06 or Paragraph 13.07, Contractor shall take no action that would void or otherwise impair Owner's special warranty and guarantee, if any, on said Work. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright® 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 54 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 13.07 Correction Period A. If within one year after the date of Substantial Completion (or such longer period of time as may be prescribed by the terms of any applicable special guarantee required by the Contract Documents) or by any specific provision of the Contract Documents, any Work is found to be defective, or if the repair of any damages to the land or areas made available for Contractor's use by Owner or permitted by Laws and Regulations as con- templated in Paragraph 6.11.A is found to be defective, Contractor shall promptly, without cost to Owner and in accordance with Owner's written instructions: 1. repair such defective land or areas; or 2. correct such defective Work; or 3. if the defective Work has been rejected by Owner, remove it from the Project and replace it with Work that is not defective, and 4. satisfactorily correct or repair or remove and replace any damage to other Work, to the work of others or other land or areas resulting therefrom. B. If Contractor does not promptly comply with the terms of Owner's written instructions, or in an emergency where delay would cause serious risk of loss or damage, Owner may have the defective Work corrected or repaired or may have the rejected Work re- moved and replaced. All claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) arising out of or relating to such correction or repair or such removal and replacement (including but not limited to all costs of repair or replacement of work of others) will be paid by Contractor. C. In special circumstances where a particular item of equipment is placed in continuous service before Substantial Completion of all the Work, the correction period for that item may start to run from an earlier date if so provided in the Specifications. D. Where defective Work (and damage to other Work resulting therefrom) has been cor- rected or removed and replaced under this Paragraph 13.07, the correction period here- under with respect to such Work will be extended for an additional period of one year after such correction or removal and replacement has been satisfactorily completed. E. Contractor's obligations under this Paragraph 13.07 are in addition to any other obliga- tion or warranty. The provisions of this Paragraph 13.07 shall not be construed as a substitute for, or a waiver of, the provisions of any applicable statute of limitation or repose. 13.08 Acceptance of Defective Work A. If, instead of requiring correction or removal and replacement of defective Work, Owner (and, prior to Engineer's recommendation of final payment, Engineer) prefers to EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 55 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT accept it, Owner may do so. Contractor shall pay all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) attribut- able to Owner's evaluation of and determination to accept such defective Work (such costs to be approved by Engineer as to reasonableness) and for the diminished value of the Work to the extent not otherwise paid by Contractor pursuant to this sentence. If any such acceptance occurs prior to Engineer's recommendation of final payment, a Change Order will be issued incorporating the necessary revisions in the Contract Documents with respect to the Work, and Owner shall be entitled to an appropriate de- crease in the Contract Price, reflecting the diminished value of Work so accepted. If the parties are unable to agree as to the amount thereof, Owner may make a Claim therefor as provided in Paragraph 10.05. If the acceptance occurs after such recom- mendation, an appropriate amount will be paid by Contractor to Owner. 13.09 Owner May Correct Defective Work A. If Contractor fails within a reasonable time after written notice from Engineer to correct defective Work, or to remove and replace rejected Work as required by Engineer in ac- cordance with Paragraph 13.06.A, or if Contractor fails to perform the Work in accor- dance with the Contract Documents, or if Contractor fails to comply with any other provision of the Contract Documents, Owner may, after seven days written notice to Contractor, correct, or remedy any such deficiency. B. In exercising the rights and remedies under this Paragraph 13.09, Owner shall proceed expeditiously. In connection with such corrective or remedial action, Owner may ex- clude Contractor from all or part of the Site, take possession of all or part of the Work and suspend Contractor's services related thereto, take possession of Contractor's tools, appliances, construction equipment and machinery at the Site, and incorporate in the Work all materials and equipment stored at the Site or for which Owner has paid Con- tractor but which are stored elsewhere. Contractor shall allow Owner, Owner's repre- sentatives, agents and employees, Owner's other contractors, and Engineer and Engi- neer's consultants access to the Site to enable Owner to exercise the rights and reme- dies under this Paragraph. C. All claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) incurred or sustained by Owner in exercising the rights and remedies under this Paragraph 13.09 will be charged against Contractor, and a Change Order will be issued incorporating the necessary revisions in the Contract Documents with respect to the Work; and Owner shall be entitled to an appropriate de- crease in the Contract Price. If the parties are unable to agree as to the amount of the adjustment, Owner may make a Claim therefor as provided in Paragraph 10.05. Such claims, costs, losses and damages will include but not be limited to all costs of repair, or replacement of work of others destroyed or damaged by correction, removal, or re- placement of Contractor's defective Work. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 56 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT D. Contractor shall not be allowed an extension of the Contract Times because of any de- lay in the performance of the Work attributable to the exercise by Owner of Owner's rights and remedies under this Paragraph 13.09. ARTICLE 14 — PAYMENTS TO CONTRACTOR AND COMPLETION 14.01 Schedule of Values A. The Schedule of Values established as provided in Paragraph 2.07.A will serve as the basis for progress payments and will be incorporated into a form of Application for Payment acceptable to Engineer. Progress payments on account of Unit Price Work will be based on the number of units completed. 14.02 Progress Payments A. Applications for Payments: 1. At least 20 days before the date established in the Agreement for each progress payment (but not more often than once a month), Contractor shall submit to Engi- neer for review an Application for Payment filled out and signed by Contractor covering the Work completed as of the date of the Application and accompanied by such supporting documentation as is required by the Contract Documents. If pay- ment is requested on the basis of materials and equipment not incorporated in the Work but delivered and suitably stored at the Site or at another location agreed to in writing, the Application for Payment shall also be accompanied by a bill of sale, in- voice, or other documentation warranting that Owner has received the materials and equipment free and clear of all Liens and evidence that the materials and equipment are covered by appropriate property insurance or other arrangements to protect Owner's interest therein, all of which must be satisfactory to Owner. 2. Beginning with the second Application for Payment, each Application shall include an affidavit of Contractor stating that all previous progress payments received on account of the Work have been applied on account to discharge Contractor's le- gitimate obligations associated with prior Applications for Payment. 3. The amount of retainage with respect to progress payments will be as stipulated in the Agreement. B. Review of Applications: 1. Engineer will, within 10 days after receipt of each Application for Payment, either indicate in writing a recommendation of payment and present the Application to Owner or return the Application to Contractor indicating in writing Engineer's rea- sons for refusing to recommend payment. In the latter case, Contractor may make the necessary corrections and resubmit the Application. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 57 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 2. Engineer's recommendation of any payment requested in an Application for Pay- ment will constitute a representation by Engineer to Owner, based on Engineer's observations of the executed Work as an experienced and qualified design profes- sional, and on Engineer's review of the Application for Payment and the accompa- nying data and schedules, that to the best of Engineer's knowledge, information and belief: a. the Work has progressed to the point indicated; b. the quality of the Work is generally in accordance with the Contract Documents (subject to an evaluation of the Work as a functioning whole prior to or upon Substantial Completion, the results of any subsequent tests called for in the Contract Documents, a final determination of quantities and classifications for Unit Price Work under Paragraph 9.07, and any other qualifications stated in the recommendation); and c. the conditions precedent to Contractor's being entitled to such payment appear to have been fulfilled in so far as it is Engineer's responsibility to observe the Work. 3. By recommending any such payment Engineer will not thereby be deemed to have represented that: a. inspections made to check the quality or the quantity of the Work as it has been performed have been exhaustive, extended to every aspect of the Work in pro- gress, or involved detailed inspections of the Work beyond the responsibilities specifically assigned to Engineer in the Contract Documents; or b. there may not be other matters or issues between the parties that might entitle Contractor to be paid additionally by Owner or entitle Owner to withhold pay- ment to Contractor. 4. Neither Engineer's review of Contractor's Work for the purposes of recommending payments nor- Engineer's recommendation of any payment, including final pay- ment, will impose responsibility on Engineer: a. to supervise, direct, or control the Work, or for the means, methods, techniques, sequences, or procedures of construction, or the safety precautions and programs incident thereto, or c. for Contractor's failure to comply with Laws and Regulations applicable to Contractor's performance of the Work, or d. to make any examination to ascertain how or for what purposes Contractor has used the moneys paid on account of the Contract Price, or EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 58 of 68 CHUNUSAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT e. to determine that title to any of the Work, materials, or equipment has passed to Owner free and clear of any Liens. 5. Engineer may refuse to recommend the whole or any part of any payment if, in En- gineer's opinion, it would be incorrect to make the representations to Owner stated in Paragraph 14.02.13.2. Engineer may also refuse to recommend any such payment or, because of subsequently discovered evidence or the results of subsequent in- spections or tests, revise or revoke any such payment recommendation previously made, to such extent as may be necessary in Engineer's opinion to protect Owner from loss because: a. the Work is defective, or completed Work has been damaged, requiring correc- tion or replacement; b. the Contract Price has been reduced by Change Orders; c. Owner has been required to correct defective Work or complete Work in accor- dance with Paragraph 13.09; or d. Engineer has actual knowledge of the occurrence of any of the events enumer- ated in Paragraph 15.02.A. C. Payment Becomes Dtte: 1. Ten days after presentation of the Application for Payment to Owner with Engi- neer's recommendation, the amount recommended will (subject to the provisions of Paragraph 14.02.13) become due, and when due will be paid by Owner to Contrac- tor. D. Reduction in Payment: 1. Owner may refuse to make payment of the full amount recommended by Engineer because: a. claims have been made against Owner on account of Contractor's performance or furnishing of the Work; b. Liens have been filed in connection with the Work, except where Contractor has delivered a specific bond satisfactory to Owner to secure the satisfaction and discharge of such Liens; c. there are other items entitling Owner to a set-off against the amount recom- mended; or d. Owner has actual knowledge of the occurrence of any of the events enumerated in Paragraphs 14.02.B.5.athrough 14.02.B.5.c or Paragraph 15.02.A. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 59 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 2. If Owner refuses to make payment of the full amount recommended by Engineer, Owner will give Contractor immediate written notice (with a copy to Engineer) stating the reasons for such action and promptly pay Contractor any amount re- maining after deduction of the amount so withheld. Owner shall promptly pay Contractor the amount so withheld, or any adjustment thereto agreed to by Owner and Contractor. when Contractor remedies the reasons for such action. 3. Upon a subsequent determination that Owner's refusal of payment was not justi- fied, the amount wrongfully withheld shall be treated as an amount due as deter- mined by Paragraph 14.02.C.I and subject to interest as provided in the Agreement. 14.03 Contractor's Warranty of Title A. Contractor warrants and guarantees that title to all Work, materials, and equipment covered by any Application for Payment, whether incorporated in the Project or not, will pass to Owner no later than the time of payment free and clear of all Liens. 14.04 Substantial Completion A. When Contractor considers the entire Work ready for its intended use Contractor shall notify Owner and Engineer in writing that the entire Work is substantially complete (except for items specifically listed by Contractor as incomplete) and request that Engi- neer issue a certificate of Substantial Completion. B. Promptly after Contractor's notification, Owner, Contractor, and Engineer shall make an inspection of the Work to determine the status of completion. If Engineer does not consider the Work substantially complete, Engineer will notify Contractor in writing giving the reasons therefor. C. If Engineer considers the Work substantially complete, Engineer will deliver to Owner a tentative certificate of Substantial Completion which shall fix the date of Substantial Completion. There shall be attached to the certificate a tentative list of items to be completed or corrected before final payment. Owner shall have seven days after receipt of the tentative certificate during which to make written objection to Engineer as to any provisions of the certificate or attached list. If, after considering such objections, Engi- neer concludes that the Work is not substantially complete, Engineer will, within 14 days after submission of the tentative certificate to Owner, notify Contractor in writing, stating the reasons therefor. If, after consideration of Owner's objections, Engineer considers the Work substantially complete, Engineer will, within said 14 days, execute and deliver to Owner and Contractor a definitive certificate of Substantial Completion (with a revised tentative list of items to be completed or corrected) reflecting such changes from the tentative certificate as Engineer believes justified after consideration of any objections from Owner. D. At the time of delivery of the tentative certificate of Substantial Completion, Engineer will deliver to Owner and Contractor a written recommendation as to division of re- sponsibilities pending final payment between Owner and Contractor with respect to se- EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paee 60 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT curity, operation, safety, and protection of the Work, maintenance, heat, utilities, insur- ance, and warranties and guarantees. Unless Owner and Contractor agree otherwise in writing and so inform Engineer in writing prior to Engineer's issuing the definitive cer- tificate of Substantial Completion, Engineer's aforesaid recommendation will be bind- ing on Owner and Contractor until final payment. E. Owner shall have the right to exclude Contractor from the Site after the date of Sub- stantial Completion subject to allowing Contractor reasonable access to remove its property and complete or correct items on the tentative list. 14.05 Partial Utilization A. Prior to Substantial Completion of all the Work, Owner may use or occupy any sub- stantially completed part of the Work which has specifically been identified in the Con- tract Documents, or which Owner, Engineer, and Contractor agree constitutes a sepa- rately functioning and usable part of the Work that can be used by Owner for its in- tended purpose without significant interference with Contractor's performance of the remainder of the Work, subject to the following conditions: 1. Owner at any time may request Contractor in writing to permit Owner to use or oc- cupy any such part of the Work which Owner believes to be ready for its intended use and substantially complete. If and when Contractor agrees that such part of the Work is substantially complete, Contractor, Owner, and Engineer will follow the procedures of Paragraph 14.04.A through D for that part of the Work. 2. Contractor at any time may notify Owner and Engineer in writing that Contractor considers any such part of the Work ready for its intended use and substantially complete and request Engineer to issue a certificate of Substantial Completion for that part of the Work. Within a reasonable time after either such request, Owner, Contractor, and Engineer shall make an inspection of that part of the Work to determine its status of comple- tion. If Engineer does not consider that part of the Work to be substantially com- plete, Engineer will notify Owner and Contractor in writing giving the reasons therefor. If Engineer considers that part of the Work to be substantially complete, the provisions of Paragraph 14.04 will apply with respect to certification of Sub- stantial Completion of that part of the Work and the division of responsibility in re- spect thereof and access thereto. 4. No use or occupancy or separate operation of part of the Work may occur prior to compliance with the requirements of Paragraph 5.10 regarding property insurance. 14.06 Final Inspection A. Upon written notice from Contractor that the entire Work or an agreed portion thereof is complete, Engineer will promptly make a final inspection with Owner and Contractor and will notify Contractor in writing of all particulars in which this inspection reveals EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Poee 61 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT that the Work is incomplete or defective. Contractor shall immediately take such meas- ures as are necessary to complete such Work or remedy such deficiencies. 14.07 Final Payment A. Application for Payment: After Contractor has, in the opinion of Engineer, satisfactorily completed all correc- tions identified during the final inspection and has delivered, in accordance with the Contract Documents, all maintenance and operating instructions, schedules, guaran- tees, bonds, certificates or other evidence of insurance, certificates of inspection, marked -up record documents (as provided in Paragraph 6.12), and other docu- ments, Contractor may make application for final payment following the procedure for progress payments. 2. The final Application for Payment shall be accompanied (except as previously de- livered) by: a. all documentation called for in the Contract Documents, including but not lim- ited to the evidence of insurance required by Paragraph 5.04.13.6; b. consent of the surety, if any, to final payment; c. a list of all Claims against Owner that Contractor believes are unsettled; and d. complete and legally effective releases or waivers (satisfactory to Owner) of all Lien rights arising out of or Liens filed in connection with the Work. 3. In lieu of the releases or waivers of Liens specified in Paragraph 14.07.A.2 and as approved by Owner, Contractor may furnish receipts or releases in full and an affi- davit of Contractor that: (i) the releases and receipts include all labor, services, ma- terial, and equipment for which a Lien could be filed; and (ii) all payrolls, material and equipment bills, and other indebtedness connected with the Work for which Owner might in any way be responsible, or which might in any way result in liens or other burdens on Owner's property, have been paid or otherwise satisfied. If any Subcontractor or Supplier fails to furnish such a release or receipt in full, Contractor may furnish a bond or other collateral satisfactory to Owner to indemnify Owner against any Lien. B. Engineer's Review of Application and Acceptance: If, on the basis of Engineer's observation of the Work during construction and final inspection, and Engineer's review of the final Application for Payment and accom- panying documentation as required by the Contract Documents, Engineer is satis- fied that the Work has been completed and Contractor's other obligations under the Contract Documents have been fulfilled, Engineer will, within ten days after receipt of the final Application for Payment, indicate in writing Engineer's recommenda- tion of payment and present the Application for Payment to Owner for payment. At EJCDC C-700 Standard General Conditions of the Construction Contract Copyright m 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paue 62 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT the same time Engineer will also give written notice to Owner and Contractor that the Work is acceptable subject to the provisions of Paragraph 14.09. Otherwise, Engineer will return the Application for Payment to Contractor, indicating in writ- ing the reasons for refusing to recommend final payment, in which case Contractor shall make the necessary corrections and resubmit the Application for Payment. C. Payment Becomes Due: 1. Thirty days after the presentation to Owner of the Application for Payment and ac- companying documentation, the amount recommended by Engineer, less any sum Owner is entitled to set off against Engineer's recommendation, including but not limited to liquidated damages, will become due and will be paid by Owner to Con- tractor. 14.08 Final Completion Delayed A. If, through no fault of Contractor, final completion of the Work is significantly delayed, and if Engineer so confirms, Owner shall, upon receipt of Contractor's final Applica- tion for Payment (for Work fully completed and accepted) and recommendation of En- gineer, and without terminating the Contract, make payment of the balance due for that portion of the Work fully completed and accepted. If the remaining balance to be held by Owner for Work not fully completed or corrected is less than the retainage stipulated in the Agreement, and if bonds have been furnished as required in Paragraph 5.01, the written consent of the surety to the payment of the balance due for that portion of the Work fully completed and accepted shall be submitted by Contractor to Engineer with the Application for such payment. Such payment shall be made under the terms and conditions governing final payment, except that it shall not constitute a waiver of Claims. 14.09 Waiver- of Claims A. The making and acceptance of final payment will constitute: 1. a waiver of all Claims by Owner against Contractor, except Claims arising from un- settled Liens, from defective Work appearing after final inspection pursuant to Paragraph 14.06, from failure to comply with the Contract Documents or the terms of any special guarantees specified therein, or from Contractor's continuing obliga- tions under the Contract Documents; and 2. a waiver of all Claims by Contractor against Owner other than those previously made in accordance with the requirements herein and expressly acknowledged by Owner in writing as still unsettled. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright © 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pear 63 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT ARTICLE 15 — SUSPENSION OF WORK AND TERMINATION 15.01 Owner May Suspend Work A. At any time and without cause, Owner may suspend the Work or any portion thereof for a period of not more than 90 consecutive days by notice in writing to Contractor and Engineer which will fix the date on which Work will be resumed. Contractor shall re- sume the Work on the date so fixed. Contractor shall be granted an adjustment in the Contract Price or an extension of the Contract Times, or both, directly attributable to any such suspension if Contractor makes a Claim therefor as provided in Paragraph 10.05. 15.02 Owner May Tenninate for Cause A. The occurrence of any one or more of the following events will justify termination for cause: 1. Contractor's persistent failure to perform the Work in accordance with the Contract Documents (including, but not limited to, failure to supply sufficient skilled work- ers or suitable materials or equipment or failure to adhere to the Progress Schedule established under Paragraph 2.07 as adjusted from time to time pursuant to Para- graph 6.04); 2. Contractor's disregard of Laws or Regulations of any public body having jurisdic- tion; 3. Contractor's repeated disregard of the authority of Engineer; or 4. Contractor's violation in any substantial way of any provisions of the Contract Documents. B. If one or more of the events identified in Paragraph 15.02.A occur, Owner may, after giving Contractor (and surety) seven days written notice of its intent to terminate the services of Contractor: 1. exclude Contractor from the Site, and take possession of the Work and of all Con- tractor's tools, appliances, construction equipment, and machinery at the Site, and use the same to the full extent they could be used by Contractor (without liability to Contractor for trespass or conversion); 2. incorporate in the Work all materials and equipment stored at the Site or for which Owner has paid Contractor but which are stored elsewhere; and 3. complete the Work as Owner may deem expedient. C. If Owner proceeds as provided in Paragraph 15.02.B, Contractor shall not be entitled to receive any further payment until the Work is completed. If the unpaid balance of the Contract Price exceeds all claims, costs, losses, and damages (including but not limited EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 64 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) sustained by Owner arising out of or relating to completing the Work, such excess will be paid to Contractor. If such claims, costs, losses, and damages exceed such unpaid balance, Contractor shall pay the difference to Owner. Such claims, costs, losses, and damages incurred by Owner will be reviewed by Engineer as to their reasonableness and, when so approved by Engi- neer, incorporated in a Change Order. When exercising any rights or remedies under this Paragraph, Owner shall not be required to obtain the lowest price for the Work per- formed. D. Notwithstanding Paragraphs 15.02.13 and 15.02.C, Contractor's services will not be terminated if Contractor begins within seven days of receipt of notice of intent to ter- minate to correct its failure to perform and proceeds diligently to cure such failure within no more than 30 days of receipt of said notice. E. Where Contractor's services have been so terminated by Owner, the termination will not affect any rights or remedies of Owner against Contractor then existing or which may thereafter accrue. Any retention or payment of moneys due Contractor by Owner will not release Contractor from liability. F. If and to the extent that Contractor has provided a performance bond under the provi- sions of Paragraph 5.0l.A, the termination procedures of that bond shall supersede the provisions of Paragraphs 15.023 and 15.02.C. 15.03 Owner May Tenninate For Convenience A. Upon seven days written notice to Contractor and Engineer, Owner may, without cause and without prejudice to any other right or remedy of Owner, terminate the Contract. In such case, Contractor shall be paid for (without duplication of any items): 1. completed and acceptable Work executed in accordance with the Contract Docu- ments prior to the effective date of termination, including fair and reasonable sums for overhead and profit on such Work; 2. expenses sustained prior to the effective date of termination in performing services and furnishing labor, materials, or equipment as required by the Contract Docu- ments in connection with uncompleted Work, plus fair and reasonable sums for overhead and profit on such expenses; 3. all claims, costs, losses, and damages (including but not limited to all fees and charges of engineers, architects, attorneys, and other professionals and all court or arbitration or other dispute resolution costs) incurred in settlement of terminated contracts with Subcontractors, Suppliers, and others; and 4. reasonable expenses directly attributable to termination. ESCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for E7CDC. All rights reserved. Pace 65 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT B. Contractor shall not be paid on account of loss of anticipated profits or revenue or other economic loss arising out of or resulting from such termination. 15.04 Contractor May Stop Work or Terminate A. If, through no act or fault of Contractor, (i) the Work is suspended for more than 90 consecutive days by Owner or under an order of court or other public authority, or (ii) Engineer fails to act on any Application for Payment within 30 days after it is submit- ted, or (iii) Owner fails for 30 days to pay Contractor any sum finally determined to be due, then Contractor may, upon seven days written notice to Owner and Engineer, and provided Owner or Engineer do not remedy such suspension or failure within that time, terminate the Contract and recover from Owner payment on the same terms as provided in Paragraph 15.03. B. In lieu of terminating the Contract and without prejudice to any other right or remedy, if Engineer has failed to act on an Application for Payment within 30 days after it is submitted, or Owner has failed for 30 days to pay Contractor any sum finally deter- mined to be due, Contractor may, seven days after written notice to Owner and Engi- neer, stop the Work until payment is made of all such amounts due Contractor, includ- ing interest thereon. The provisions of this Paragraph 15.04 are not intended to pre- clude Contractor from making a Claim under Paragraph 10.05 for an adjustment in Contract Price or Contract Times or otherwise for expenses or damage directly attribut- able to Contractor's stopping the Work as permitted by this Paragraph. ARTICLE 16 — DISPUTE RESOLUTION 16.01 Methods and Procedures A. Either Owner or Contractor may request mediation of any Claim submitted to Engineer for a decision under Paragraph 10.05 before such decision becomes final and binding. The mediation will be governed by the Construction Industry Mediation Rules of the American Arbitration Association in effect as of the Effective Date of the Agreement. The request for mediation shall be submitted in writing to the American Arbitration As- sociation and the other party to the Contract. Timely submission of the request shall stay the effect of Paragraph 10.05.E. B. Owner and Contractor shall participate in the mediation process in good faith. The process shall be concluded within 60 days of filing of the request. The date of termina- tion of the mediation shall be determined by application of the mediation rules refer- enced above. C. If the Claim is not resolved by mediation, Engineer's action under Paragraph 10.05.0 or a denial pursuant to Paragraphs 10.05.C.3 or 10.05.D shall become final and binding 30 days after termination of the mediation unless, within that time period, Owner or Contractor: EJCDC C-700 Standard General Conditions of the Construction Contract Copyright© 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Paue 66 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 1. elects in writing to invoke any dispute resolution process provided for in the Sup- plementary Conditions; or 2. agrees with the other party to submit the Claim to another dispute resolution proc- ess; or 3. gives written notice to the other party of the intent to submit the Claim to a court of competent jurisdiction. ARTICLE 17 —MISCELLANEOUS 17.01 Giving Notice A. Whenever any provision of the Contract Documents requires the giving of written no- tice, it will be deemed to have been validly given if: 1. delivered in person to the individual or to a member of the firm or to an officer of the corporation for whom it is intended; or 2. delivered at or sent by registered or certified mail, postage prepaid, to the last busi- ness address known to the giver of the notice. 17.02 Computation of Times A. When any period of time is referred to in the Contract Documents by days, it will be computed to exclude the first and include the last day of such period. If the last day of any such period falls on a Saturday or Sunday or on a day made a legal holiday by the law of the applicable jurisdiction, such day will be omitted from the computation. 17.03 Cumulative Remedies A. The duties and obligations imposed by these General Conditions and the rights and remedies available hereunder to the parties hereto are in addition to, and are not to be construed in any way as a limitation of, any rights and remedies available to any or all of them which are otherwise imposed or available by Laws or Regulations, by special warranty or guarantee, or by other provisions of the Contract Documents. The provi- sions of this Paragraph will be as effective as if repeated specifically in the Contract Documents in connection with each particular duty, obligation, right, and remedy to which they apply. 17.04 Survival of Obligations A. All representations, indemnifications, warranties, and guarantees made in, required by, or given in accordance with the Contract Documents, as well as all continuing obliga- tions indicated in the Contract Documents, will survive final payment, completion, and acceptance of the Work or termination or completion of the Contract or termination of the services of Contractor. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright O 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Pace 67 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY STANDARD CONDITIONS OF ATKA, ALASKA THE CONSTRUCTION CONTRACT 17.05 Controlling Law A. This Contract is to be governed by the law of the state in which the Project is located. 17.06 Headings A. Article and paragraph headings are inserted for convenience only and do not constitute parts of these General Conditions. EJCDC C-700 Standard General Conditions of the Construction Contract Copyright 9 2007 National Society of Professional Engineers for EJCDC. All rights reserved. Page 68 of 68 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA Blank Page EJCDC C-700 Standard General Conditions of the Construction Contract Copyright 0 2007 National Society of Professional Engineers for EJCDC. All rights reserved. CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY SUPPLEMENTAL CONDITIONS ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA SUPPLEMENTAL CONDITIONS CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY SUPPLEMENTAL CONDITIONS ATKA,ALASKA Supplemental Conditions A. These Supplementary Conditions amend or supplement the Standard General Conditions of the Construction Contract, EJCDC C-700 (2007 Edition). All provisions which are not so amended or supplemented remain in full force and effect. B. The terms used in these Supplementary Conditions have the meanings stated in the General Conditions. Additional terms used in these Supplementary Conditions have the meanings stated below, which are applicable to both the singular and plural thereto. C. The address system used in these Supplementary Conditions is the same as the address sys- tem used in the General Conditions, with the prefix "SC" added thereto. D. SC-4.06 Delete Paragraphs 4.06.A and 4.06.13 in their entirety and insert the following: A. No reports or drawings related to Hazardous Environmental Conditions at the Site are known to the Owner. E. SC-5.04 Add the following after Section 5.04.B: C. The limits of liability for the insurance required b Paragraph 5.04 of the General Condi- tions shall provide coverage for not less than the following amounts or greater where re- quired by Laws and Regulations: 1. Workers Compensation, and related coverages under Paragraphs 5.04.A.1 and A.2 3 of the General Conditions: - --. a. State: Statutory b. Applicable Federal (e.g., Longshoremans): Statutory r- c. Employers Liability: $500,000 ' 12. Contractors General Liability under Paragraphs 5.04.A.3 through A.6 of the Gen- eral Conditions which shall include completed Operations and Product Liability coverages and eliminate the exclusion with respect to property under the care, cus- tody and control of Contractor: a.. General Aggregate: $2,000,000 b. Products - Completed Operations Aggregate: $2,000,000 -r c. Personal and Advertising Injury: $1,000,000 d. Each Occurrence (Bodily Injury and Property Damage: $1,000,000 S e. Property Damage liability insurance will provide Explosion, Collapse, and Un- derground coverages where applicable. f. Excess or Umbrella Liability (General and Each Occurrence): $2,000,000 3. Automobile Liability under Paragraph 5.04.A.6 of the General Conditions: a. Bodily Injury (Each Person and Each Accident): $1,000,000 b. Property Damage (Each Accident): $1,000,000 Page I of 3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY SUPPLEMENTAL CONDITIONS ATKA,ALASKA 4. The Contractor Liability coverage required by Paragraph 5.04.B.4 of the General Conditions shall provide coverage for not less than the following amounts: a. Bodily Injury (Each Person and Each Accident): $1,000,000 b. Property Damage (Each Accident and Annual Aggregate): $2,000,000 F. SC-5.06 Delete Paragraph 5.06.B and replace with the following: B. Contractor shall purchase and maintain, and any other additional property insurance re- quired by Laws and Regulations, which insurance will include the interest of Owner, Con- tractor, Subcontractors, and Engineer and the officers, directors, partners, employees, agents, consultants and subcontractors of each and any of them, each of whom is deemed to have an insurable interest and shall be listed as a loss payee. G. SC-6.06 Add a new Paragraph immediately after Paragraph 6.06.G: H. Owner may furnish to any Subcontractor or Supplier, to the extent practicable, informa- tion about amounts paid to Contractor on account of Work performed for Contractor by a particular Subcontractor or Supplier. H. SC-17.07 Add new Paragraphs immediately after Paragraph 17.06 I. 17.07 Owner Supplied Buildings and Equipment J. A. The Owner will supply a 2 bedroom furnished apartment for the Contractor's em- ployees and subcontractors from the date of the commencement of the W6rk until the agreed date for Final Completion. Meals are NOT included. K. B. The Owner will provide the following equipment for Contractors use at the Project Site. Equipment is supplied dry, without an operator. Contractor is required to main- tain daily equipment usage logs noting hours equipment used. i. Honda 4-wheeler (20) ii. Ford half -ton pickup (20) 2of3 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA PROJECT DRAWINGS & SPECIFICATIONS m 0 Page 1 CHUNIISAX HYDROELECTRIC DISPACTABLE ENERGY ATKA,ALASKA Project Drawings & Specifications G-1 SITE PLAN & VICINITY MAP E-1 ELECTRICAL SITE PLAN E-2 ELECTRICAL SYSTEM 1-LINE DIAGRAM E-3 HYDRO PLANT FLOOR PLAN & SPECIFICATIONS E-4 CLINIC/CITY OFFICE FLOOR PLAN & DETAILS E-5 COMMUNITY BLDG FLOOR PLAN & DETAILS E-6 TRIBALARA OFFICE FLOOR PLAN & DETAILS E-7 POST OFFICE FLOOR PLAN & DETAILS E-8 CITY SHOP FLOOR PLAN & DETAILS E-9 FIRE STATION FLOOR PLAN & DETAILS M-1 LEGEND & SCHEDULES, DRAWING INDEX & NOTES M-2 SPECIFICATIONS M-3 CLINIC/CITY OFFICE BOILER PLAN, & PIPING SCHEMATIC M-4 TRIBAL/IRA OFFICE BOILER PLAN, & PIPING SCHEMATIC m - r . 1of15