Loading...
HomeMy WebLinkAboutAttachment C, DesignELECTRICAL DRAWINGS E0.1 ELECTRICAL LEGEND ABBREVIATIONS & SPECIFICATIONS E2.1 LIGHTING REMODEL PLAN E3.1 POWER & SIGNAL REMODEL PLAN MECHANICAL DRAWINGS FP1.1 FIRE PROTECTION PLANS M0.1 MECHANICAL LEGEND, ABBREVIATIONS & SCHEDULES M0.2 MECHANICAL SCHEDULES M1.1 MECHANICAL SITE PLAN M1.2 ENLARGED MECHANICAL PLANS M1.3 UTILITY BUILDING DETAILS M1.4 12-PLEX BOILER ROOM DEMOLITION PLANS M1.5 12-PLEX BOILER ROOM REMODEL PLANS CIVIL DRAWINGS C1.0 HEATED CLYCOL SUPPLY & RETURN SITE PLAN C2.0 CIVIL DETAILS (907) 243-8985 Anchorage, AK. 99517 Suite 2100 3710 Woodland Dr. +PE LARSEN CONSULTING GROUP architecture engineering surveying Plotted By:Date/Time:Layout:Filename:.%) DRAWING SYMBOLS 1 A1 1 A1 DETAIL TAG SECTION TAG INTERIOR ELEVATION TAG LEVEL LINE CONTROL POINT OR DATUM 1 Floor Plan 1/4" = 1'-0"A1 ROOM NAME 101 TITLE FOR PLAN/DETAIL WALL TYPE TAG WINDOW TAG ROOM NAME & NUMBER TAG DOOR TAG 101 W2 C PROJECT DESCRIPTION PROJECT TEAM GENERAL NOTES DRAWING INDEX A1 E F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:07 PMAVCP-RHA CENTRAL HEAT PLANT BIOMASS UPGRADESuA0BETHEL ALASKA CENTRAL HEAT PLANT BIOMASS UPGRADES 09/11/12 888.111.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE MOST RECENT ADOPTED EDITION OF THE INTERNATIONAL BUILDING CODE, NFPA, INTERNATIONAL MECHANICAL CODE, UNIFORM PLUMBING CODE, NATIONAL ELECTRICAL CODE, AND ALL LOCAL AND STATE OF ALASKA CODE REGULATIONS AND AMENDMENTS. 2.THE ORGANIZATION OF THESE DRAWINGS IS NOT INTENDED TO CONTROL THE DIVISION OF WORK AMONG SUB-CONTRACTORS. THE DIVISION OF THE WORK SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 3.THE CONTRACTOR IS RESPONSIBLE FOR CONFORMING TO ALL APPLICABLE LOCAL CODES AND TRADE STANDARDS. 4.THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONARY MEASURES TO PROTECT THE PUBLIC AND ADJACENT PROPERTIES FROM DAMAGE THROUGHOUT CONSTRUCTION. CONTRACTOR ASSUMES ALL LIABILITY FOR DAMAGES INCURRED DURING CONSTRUCTION. 5.THE CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT AND MATERIALS REQUIRED TO COMPLETE ALL WORK AS SHOWN OR AS IMPLIED ON THESE DRAWINGS AND THE SPECIFICATIONS.. 6.THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL FACILITIES FOR HEAT, LIGHT AND POWER WITHIN THE PREMISES AND IN THE CONSTRUCTION AREA DURING THE ENTIRE CONSTRUCTION PERIOD. PROVIDE NECESSARY MATERIALS AND LABOR FOR POWER CONNECTIONS FOR MACHINES, PORTABLE, ETC. AS USED BY OTHER TRADES, REGARDLESS OF SIZE. 7.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO CONSTRUCTION. IF A CONDITION NOT COVERED IN THE DRAWINGS IS ENCOUNTERED, OR IF A DIMENSIONAL ERROR IS FOUND, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE COMMENCING WITH THAT PORTION OF THE WORK. 8.ALL COMPONENTS, EQUIPMENT, ETC., SHALL BE INSTALLED PER MANUFACTURERS PRINTED RECOMMENDATIONS. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL RUBBISH AND DEBRIS RESULTING FROM CONSTRUCTION. 10.ALL COLOR SELECTION SHALL BE PER THE COLOR SCHEDULE OR IF NOT ON THE COLOR SCHEDULE THEN SUBMIT TO THE ARCHITECT FOR APPROVAL. 11.ALL DIMENSIONS ARE TO FACE OF STUDS, FACE OF PANEL SHEATHING, GRID LINES, FACE OF ROUGH OPENING, UNLESS INDICATED OTHERWISE. 12.CAULK ALL JOINTS, PROVIDE BACKER ROD AS NEEDED, AND PROVIDE FLASHING & COUNTER FLASHING AS NEEDED TO PROVIDE COMPLETE WEATHER PROOF INSTALLATION. ARCHITECT, STRUCTURAL AND CIVIL ENGINEERS LARSEN CONSULTING GROUP, INC. (PROJECT # 888.10) (907) 243-8985 MECHANICAL AND ELECTRICAL ENGINEERS RSA ENGINEERING, INC. (907) 276-0521 THIS PROJECT CONSISTS OF AN EXPANSION OF THE EXISTING UTILITY BUILDING FOR IT TO BECOME A CENTRAL HEATING PLANT FACILITY WHICH WILL SERVICE # BUILDINGS TO PROVIDE A CAMPUS-WIDE HEATING NETWORK. THE SCOPE INCLUDES DOUBLING THE SIZE OF THE EXISTING BUILDING TO HOUSE A BIOMASS BOILER AND TWO OIL-FIRED BACK-UP BOILERS. NEW SITEWORK PIPING WILL EXTEND AROUND THE CAMPUS AND CONNECT TO EXISTING BUILDINGS TO CREATE A CONTINUOUS LOOP. APPLICABLE CODES AND STANDARDS: -2006 INTERNATIONAL BUILDING CODE (IBC) -2006 INTERNATIONAL FIRE CODE (IFC) -2006 INTERNATIONAL MECHANICAL CODE (IMC) -2006 UNIFORM PLUMING CODE (UPC) -2008 NFPA 70 NATIONAL ELECTRIC CODE (NEC) -ADA ACCESSIBILITY GUIDELINES (ADAAG) AVIATION SCHOOL DORMITORY CODE STUDY CODE SUMMARY -OCCUPANCY CLASS: R-2 DORMITORY -CONSTRUCTION TYPE: V-A (1 HOUR RATED) -SPRINKLER SYSTEM: PROVIDED -FIRE ALARM SYSTEM: NOT REQUIRED -FIRE EXTINGUISHERS: PROVIDED (IBC 906 AND NFPA 10) -MAXIMUM OCCUPANT LOAD: 196 (IBC 1004.4.4) -ALLOWABLE AREA: 23,993 SF ACTUAL AREA: 9,760 SF -ALLOWABLE HEIGHT: 2 STORIES ARCHITECTURAL DRAWINGS uA1 FLOOR PLAN uA3 ELEVATIONS uA5 SHEET SPECIFICATIONS uA2 ROOF PLAN uA4 SECTIONS uA0 COVER STRUCTURAL DRAWINGS uS2 MEZZANINE & ROOF FRAMING PLANS uS1 PILE LAYOUT AND FLOOR FRAMING PLAN uS4 STRUCTURAL DETAILS uS3 BUILDING SECTION uS2.1 SHEARWALL PLAN uS3.1 WALL SECTIONS DN UP DN WH OFFICE WORK SHOP ELECTRICAL ROOM GARAGE 1 1 2 4 5 5 A E D B 3 C 8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"10'-0"10'-0"10'-0"10'-0"C' 201 D' E' B' 200 F' 1.8 2.6 3.4 4.2 40'-0"40'-0"40'-0" 202 SEE MECHANICAL FOR EQUIPMENT LAYOUT NEW BUILDING EXISTING BUILDING MECHANICAL BOILER ROOM STORAGE W2 W3 W1 1 uA4 2 uA4 B-1 B-2 B-3 B-4, PELLET BOILER GT-1 ET-1 BT-1 CP-3A CP-3B CP-1 CP-2 CP-3 DT-1 VF-1 CP-4 1 uS3 2 uS3 3 uS4 TYP 203 STORAGE 1 uS3.1 3 uS3.1 2 uS3.1 FLOORPER SCHEDULEPER SCHEDULE 2"3 1/2" TYP4'-0"1'-4"(EXTERIOR TO INTERIOR) TRILAP STEEL SIDING AIR INFILTRATION RETARDER 8" SIP PANEL (MIN R-24) VAPOR RETARDING PAINT (LEFT TO RIGHT) 3/8" SHEATHING 2x6 WOOD STUDS @ 16" O.C. 3/8" SHEATHING (LEFT TO RIGHT) 3/8" SHEATHING 2x4 WOOD STUDS @ 16" O.C. 3/8" SHEATHING 4 5 A 3 C' B' 2.6 3.4 4.2 1 uA4 2 uA4 204 RESTROOM 4 uS4 3 uS3.1 ASKLAFAETASTOT49thTSIGER EDRECETIHRALAOISSENCFORPWallace H. SwansonNo. A7904SHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121As indicated F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:09 PMuA1 888.11 09/11/12 RW RM/MSM RWFLOOR PLANCENTRAL HEAT PLANTBIOMASS UPGRADESuA15 3/16" = 1'-0"uA1 1 FLOOR PLAN Door Schedule Mark Width Height Frame Type Description 200 3' - 0"7' - 0"METAL EXTERIOR 201 3' - 0"7' - 0"METAL INTERIOR 202 3' - 0"7' - 0"METAL INTERIOR 203 2' - 6"7' - 0" 204 2' - 10"7' - 0" Window Schedule Type Mark Count Type Description A 3 48" x 16"VINYL FIXED WINDOW B 5 16" x 48"VINYL FIXED WINDOW 1/4" = 1'-0"D SINGLE FLUSH 1/4" = 1'-0"A A- FIXED 3" = 1'-0"W1 SIP WALL W/ SIDING 3" = 1'-0"W2 2x6 PLUMBING WALL W/ PANELING 3" = 1'-0"W3 2x4 WALL W/ PANELING Room Finish Schedule Name Area Floor Finish Wall Finish Ceiling Finish Comments MECHANICAL BOILER ROOM 1,017 SF PT-1 PT-1 & PT-2 PT-1 RESTROOM 70 SF STORAGE 238 SF PT-1 PT-1 & PT-2 PT-2 STORAGE 231 SF PT-1 PT-1 & PT-2 PT-1 STORAGE Not Placed PT- 1 VAPOR RETARDING PAINT- OFF WHITE PT- 2 LATEX PAINT- OFF WHITE * ALL PAINT APPLIED DIRECTLY TO SUBSTRATE NODATEBYREVISION 3/16" = 1'-0"uA1 2 MEZZANINE WH 1 5 A C' D' E' B' F' 1.8 2.6 3.4 4.2 40' - 0" 2:12 1 uA4 2 uA4 NEW BUILDING EXISTING BUILDING 1 uS3 2 uS3 1 uS3.1 3 uS3.1 55º RADIUS CURVED 24'' TJI @ 24'' O.C. 2 uS3.1 SIP WALL SYTEM PREFINISHED METAL ROOFING - REFER TO MANUF RECOMMENDATIONS FOR ALL SEALANTS AND CONCEALED FASTENER DETAILING ICE & WATER SHIELD OVER ENTIRE ROOF SIP ROOF SYSTEM 8" RIGID INSULATIONEXTEND METAL PANELS PAST ROOF EDGE PREFINISHED METAL FLASHING TO MATCH ROOFING - REFER TO MANUF RECOMMENDATIONS FOR ALL SEALANTS AND CONCEALED FASTENER DETAILING CONT 2x8 RIM SUPPORT 3/4" PLYWOOD FILLER BUILDLING WRAP W/ INTEGRAL AIR INFILTRATION RETARDER LAP ICE & WATER SHIELD OVER FLASHING 2x4 EDGE SUPPORT 2x BLOCKING @ EA TRUSS EXTENSION RIBBED METAL SOFFIT CONT VAPOR RETARDER LINE OF OUTLOOKER EXTERIOR METAL SIDING 1' - 0" PREFINISHED WALL PANEL CONT VAPOR RETARDER CEILING PANEL SIP WALL SYTEM PREFINISHED METAL ROOFING - REFER TO MANUF RECOMMENDATIONS FOR ALL SEALANTS AND CONCEALED FASTENER DETAILING ICE & WATER SHIELD OVER ENTIRE ROOF 5/8" PLYWOOD SHEATHING FASTENED THROUGH TO SIP 8" SIP ROOF PANEL EXTEND METAL PANELS PAST ROOF EDGE 22 GA PREFINISHED METAL FLASHING TO MATCH ROOFING BUILDLING WRAP W/ INTEGRAL AIR INFILTRATION RETARDER LAP ICE & WATER SHIELD OVER FLASHING 22 GA PERFORATE VENT FLASHING TO BE CONTINOUS 35% OPEN FREE AREA EXTERIOR METAL SIDING 2x4 RUNNERS @ 24" OC 4" RIGID INSULATION 3"1' - 3"ASKLAFAETASTOT49thTSIGER EDRECETIHRALAOISSENCFORPWallace H. SwansonNo. A7904SHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121As indicated F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:10 PMuA2 888.11 09/11/12 RW MSM RWROOF PLANCENTRAL HEAT PLANTBIOMASS UPGRADESuA25 3/16" = 1'-0"uA2 1 ROOF PLAN 1 1/2" = 1'-0"uA2 2 _ RAKE DETAIL with SIP 1 1/2" = 1'-0"uA2 3 _EAVE OVERHANG with SIP NODATEBYREVISION MAIN LEVEL 0" LOWER PLATE 10' - 0" UPPER PLATE 16' - 8" MEZZANINE 10' - 0" A A NEW CURVED METAL ROOF NEW METAL SIDING NEW METAL STAIRS AND RAILING A B B B NEW METAL SIDING 200 ASKLAFAETASTOT49thTSIGER EDRECETIHRALAOISSENCFORPWallace H. SwansonNo. A7904SHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121As indicated F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:13 PMuA3 888.11 09/11/12 RW JR/MSM RWELEVATIONSCENTRAL HEAT PLANTBIOMASS UPGRADESuA35 1/8" = 1'-0"uA3 1 LEFT ELEVATION 3/16" = 1'-0"uA3 4 RIGHT ELEVATION 3/16" = 1'-0"uA3 2 FRONT ELEVATION 3/16" = 1'-0"uA3 3 REAR ELEVATION NODATEBYREVISION MAIN LEVEL 0" 1 5 1.8 2.6 3.4 4.2 MEZZANINE 10' - 0" STORAGE W1 W3 uA2 3 uS3.1 3 MAIN LEVEL 0" LOWER PLATE 10' - 0" A EDBC UPPER PLATE 16' - 8" C'D'E'B'F' MEZZANINE 10' - 0" MECHANICAL BOILER ROOM STORAGE A 200 202 W2 W3 A WH B B ASKLAFAETASTOT49thTSIGER EDRECETIHRALAOISSENCFORPWallace H. SwansonNo. A7904SHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121 1/4" = 1'-0"F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:15 PMuA4 888.11 09/11/12 RW MSM RWSECTIONSCENTRAL HEAT PLANTBIOMASS UPGRADESuA45 1/4" = 1'-0"uA4 1 CROSS SECTION 1/4" = 1'-0"uA4 2 LONGITUDINAL SECTION NODATEBYREVISION CAULKING COMPOUND AFM SAFECOAT CAULKING COMPOUND DOORS- METAL CECO HOLLOW METAL DOOR-- 14 GAUGE. REINFORCEMENT FOR CLOSER AND EXIT HARDWARE-- PREPRIMED-- SIZE AND CONFIGURATION PER DOOR SCHEDULE DOOR FRAMES- METAL HOLLOW METAL DOOR FRAME-- 16 GAUGE. FIRE EXTINGUISHER JL INDUSTRIES, COSMIC MULTI-PURPOSE DRY CHEMICAL -- 2A-10BC RECHARGEABLE -- 5 LBS, RED FIRE EXTINGUISHER CABINET JL INSUDTRIES, CLEAR VU SERIES -- SEMI-RECESSED -- FULL ACRYLIC DOOR WITH SAF-T-LOK AND CLEAR ACRYLIC PLASTIC CONVEX BUBBLE GLAZING -- STAINLESS STEEL DOOR FRAME AND 3" TRIM INSULATION CEILING: MIN. R-30 - RIGID SIP INSULATION FLOOR: MIN. R-50 - BATT WALL: MIN. R-30 - RIGID SIP INSULATION METAL FRAMING 25 GAUGE - SCAFCO PRODUCT OR EQUAL PT- 1 VAPOR RETARDING PAINT PT- 2 LATEXT PAINT SEALANT OSI PRO SERIES H2U ACRYLIC URETHANE SEALANT (INTERIOR)(OR EQUIVALENT - MUST BE APPROVED BY ARCHITECT) EAVE SOFFIT VENT ALCOA TRIPLE 3 1/3 VENTURA HIDDEN VENT SOFFIT -- #44 "LINEN" (OR EQUIVALENT - MUST BE APPROVED BY ARCHITECT) HANDRAILS R&B WAGNER SERIES 500 11/2" DIAMETER ALUMINUM PIPE RAILING (OR EQUIVALENT - MUST BE APPROVED BY ARCHITECT) GRIP STRUT GRATING 1 1/2" THICK, 3'-6" MIN LENGTH GUTTERS VINYL GUTTERS WITH LEAF AND ICE PROTECTION- ORSSG LEAF RELIEF SYSTEM (OR EQUIVALENT- MUST BE APPROVED BY ARCHITECT) HEAVY DUTY GRIP STRUT BRIDGE 2" THICK, 3'-0" MIN LENGTH ICE & WATER SHIELD GRACE ICE & WATER SHIELD METAL ROOF AEP SPAN SPAN-LOK -- 22 GAUGE, 16" WIDE, 2" HIGH -- "TAHOE BLUE" (REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND DETAILS) METAL FLASHING 24 GAUGE -- COLOR TO MATCH METAL ROOF AND SIDING METAL SIDING AEP SPAN PRE-FORMED SIDING -- "NATURAL CLAY" RAKE SOFFIT PANEL ALCOA TRIPLE 3 1/3 MATCH ROOF (OR EQUIVALENT - MUST BE APPROVED BY ARCHITECT) RAINSCREEN FABRIC BENJAMIN OBDYKE HOME SLICKER 10 -- 10 MM THICK SEALANT (EXTERIOR)AC PRODUCTS, FLEXIBLE SEAL SILL SEALER DOW STYROFOAM SILL SEALER GALVANIZED STEEL FENCING ATTACH WITH 16 GAUGE, 1" WIDE, 11/4" LEG GALVANIZED CONSTRUCTION STAPLES STAIR TREADS MCNICHOLS ALUMINUM GRIP-STRUT STAIR TREADS -- MODEL T-32012-A WINDOWS NORTHERN VINYL WINDOWS -- TRIPLE-PANE, LOW-E GLAZING, CLASS 60 UL RATING -- SIZE/CONFIGURATION PER WINDOW TYPES -- INSTALL WINDOW PROTECTION FILM WINDOW PROTECTION FILM BEKAERT ANCHORED ARMORCOAT 8 MIL SAFETY FILM MATERIALS:ASKLAFAETASTOT49thTSIGER EDRECETIHRALAOISSENCFORPWallace H. SwansonNo. A7904SHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121 12" = 1'-0"F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:15 PMuA5 888.11 09/11/12 RW MSM RWSHEET SPECIFICATIONSCENTRAL HEAT PLANTBIOMASS UPGRADESuA55 NODATEBYREVISION UP DN 1 1 2 4 5 5 A B 3 C 8'-0"8'-0"8'-0"8'-0"8'-0" 10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"8'-0"8'-0"8'-0"8'-0"8'-0"C' D' E' B' 6" SCH 40 STD PIPE, 40' MIN EMBEDMENT (TYP OF 31) - SET TOP OF NEW PILES SO THAT TOP OF NEW GLB MATCH TOP OF EXISTING GLB F'BUILDING ADDITION40'-0"1.8 2.6 3.4 4.2 40'-0" 3" TYP SHADE DENOTES EXISTING STRUCTURE TO REMAIN3" TYP3" TYP uS4 1 TYP 1 uS3 2 uS3 NEW BUILDING EXISTING BUILDING 6-3/4''x7-1/2'' GLB 3'-2 3/4"4'-9 1/4"1 uS3.1 3 uS3.1 2 uS3.1 1 1 2 4 5 5 A B 3 C' D' E' B' F' 1.8 2.6 3.4 4.2 8'-0"8'-0"8'-0"8'-0"8'-0" 10'-0"10'-0"10'-0"10'-0"10'-0"8'-0"8'-0"8'-0"8'-0"8'-0"BUILDING ADDITION40'-0"40'-0" SHADE DENOTES EXISTING STRUCTURE TO REMAIN 1-1/8" T&G SHEATHING - GLUED & NAILED W/ 10d @ 6" OC ALL EDGES 12" OC @ INTERMEDIATE SUPPORTS (TYP)GLB 6.75 x 16.5GLB 6.75 x 16.5GLB 6.75 x 16.5GLB 6.75 x 16.5GLB 6.75 x 16.5GLB 6.75 x 16.5GLB 6.75 x 16.5 11 7/8" RED-I65 JOISTS@ 16" O.C. TYP.2 uS4 TYP 1 uS3 2 uS3 CANTILEVER DECK BEAMS 4'-0"3-1/2x11-7/8 RIM JOIST MEG7 HGR TO (E) GLB IN SIMPSON HUTF OFFSET HGRS 6-3/4''x7-1/2'' GLB NEW BUILDING EXISTING BUILDING 6-3/4''x7-1/2'' GLB 1 uS3.1 3 uS3.1 2 uS3.1 ASKLAFAETASTO49thTSIGER EDREREEINELAOISSENGFORPDanny O. GrahamCE-10656NSHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121 3/16" = 1'-0"F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:16 PMuS1 888.11 09/11/12 DG RW DGPILE LAYOUT AND FLOOR FRAMINGPLANCENTRAL HEAT PLANTBIOMASS UPGRADESuS14 3/16" = 1'-0"uS1 1 PILE LAYOUT PLAN 3/16" = 1'-0"uS1 2 FLOOR FRAMING PLAN NODATEBYREVISION 1 5 A C' D' E' B' F' 1.8 2.6 3.4 4.2 1-1/8" T&G SHEATHING - GLUED & NAILED W/ 10d @ 6" OC ALL EDGES 12" OC @ INTERMEDIATE SUPPORTS (TYP) 11 7/ 8 " R E D - I 6 5 J O I S T S @ 16 " O . C . T Y P . 3-1/2" x 11-7/8" ML JOIST-BEARING LEDGERGLB 6.75 x 16.5GLB 6.75 x 16.5 6x6 WOOD COLUMN SIMPSON CCT7 CAP 2:12 1 5 A C' D' E' B' F' 1.8 2.6 3.4 4.2 40'-0"40'-0"55° RADIUS CURVED 24'' TJL @ 24'' O.C.2'-0"ASKLAFAETASTO49thTSIGER EDREREEINELAOISSENGFORPDanny O. GrahamCE-10656NSHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121 3/16" = 1'-0"F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:17 PMuS2 888.11 09/11/12 DG JR DGMEZZANINE & ROOF FRAMING PLANSCENTRAL HEAT PLANTBIOMASS UPGRADESuS24 3/16" = 1'-0"uS2 1 LOW ROOF & MEZZANINE FLOOR FRAMING 3/16" = 1'-0"uS2 2 HIGH ROOF FRAMING PLAN NODATEBYREVISION 1 1 2 4 5 5 A B 3 C C' D' E' B' F' 1.8 2.6 3.4 4.2 NEW BUILDING EXISTING BUILDING 9300 # 9300# LATERAL LOAD TO SIPS PANEL AS INDICATED (TYP.)9500#9500#HDR HDRHDR ASKLAFAETASTO49thTSIGER EDREREEINELAOISSENGFORPDanny O. GrahamCE-10656NSHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121 3/16" = 1'-0"F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:17 PMuS2.1 888.11 09/11/12 Checker Author DesignerSHEARWALL PLANCENTRAL HEAT PLANTBIOMASS UPGRADESuS2.14 NODATEBYREVISION 3/16" = 1'-0"uS2.1 1 SHEARWALL PLAN 1 2 12 8'' SIP PANEL 8'' SIP PANEL 6-3/4''x16-1/5'' GLB 11-7/8'' RED-I65 @ 16'' O.C. PILE CAP 6'' STEEL PILE10'-0"1'-0" 5 10'-0"17'-10 3/4"7'-10 3/4"1-1/8'' T&G SHEATHING 8'' SIP PANEL WALL 2.6 LVL ASKLAFAETASTO49thTSIGER EDREREEINELAOISSENGFORPDanny O. GrahamCE-10656NSHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121As indicated F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:19 PMuS3.1 888.11 09/11/12 Checker Author DesignerWALL SECTIONSCENTRAL HEAT PLANTBIOMASS UPGRADESuS3.14 NODATEBYREVISION 3/4" = 1'-0"uS3.1 1 WALL SECTION - LOW ROOF 3/4" = 1'-0"uS3.1 3 WALL SECTION - HIGH ROOF 1/2" = 1'-0"uS3.1 2 WALL SECTION - ROOF INTERSECTION STRUCTURAL SHEATHING - SEE MAIN LEVEL JOIST FRAMING PLAN AND DIAPHRAGM SCHEDULE GLU-LAM BEAMS - SEE MAIN LEVEL BEAMS PLAN SIMPSON COLUMN CAP - SEE PILE CAP SCHEDULE STEEL PILE - SEE PILE LAYOUT AND SCHEDULE 1/4 3/16 P 5/8x16" SQUAREL ~T.O. SHEATHING TO B.O. BEAM1' - 5 5/8"SIP WALL SYTEM CONT WOOD PLATE W/ 16d @ 8" OC STAGGERED 3/8" PLYWOOD SHEATHING INFILL BN FLOOR BEAM AND FRAMING (SEE FRAMING PLANS) BN SIP NAILING PER MANUF SPECIFICATIONS MST27 STRAP @ PANEL EDGES (TYPICAL) ~ TYP 3" 2x BLOCKING FOR SOFFIT SUPPORT BEAM PLATE NAILING PER SIP MANUFACTURER REQ'S C OF RAILING AND STEEL BEAML C12x20.7 STRINGERS AND BEAMS, GALVANIZED STEEL GRATE DECKING AND TREADS NON-CONTINUOUS HANDRAILS TO RETURN AT END POSTS (TYP) ATTACH HANDRAIL @ EACH POST (TYP) PT 4x12 MUD SILL GRADE (SEE CIVIL) 5'-0" MAX MAX7"MIN 11"FIELD VERIFY9'-10" 2" (E) WALL TO REMAIN 3-1/2'' x 11-7/8'' ML LEDGER SIMPSON HANGER 11-7/8'' (?) REDBUILT (FLOORPLAN IS REF TJI) 1-1/8'' PLYWOOD SHEATHING ASKLAFAETASTO49thTSIGER EDREREEINELAOISSENGFORPDanny O. GrahamCE-10656NSHEET NUMBER DATE: FILE NO. DRAWN BY: CHECKED BY: SCALE: DESIGNED BY: OF Plotted By:Date/Time:Layout:Filename:+PE.%)3710 Woodland Dr., Suite 2100Anchorage, AK 99517(907) 243-8985LARSEN CONSULTING GROUParchitecture engineering & surveyingAVCPRHARegional HousingAuthority405 Ptarmigan Rd.Bethel, Alaska 99559(907) 543-3121As indicated F:\Architectural Projects\888.11 Central Heating Plant\888.11 Central Heating Plant.rvt9/12/2012 2:15:20 PMuS4 888.11 09/11/12 DG RW DGSTRUCTURAL DETAILSCENTRAL HEAT PLANTBIOMASS UPGRADESuS44 1 1/2" = 1'-0"uS4 1 TYPICAL PILE CAP DETAIL 1 1/2" = 1'-0"uS4 2 JOIST AT BEAM 1/2" = 1'-0"uS4 3 EXTERIOR STAIR SECTION NODATEBYREVISION 1 1/2" = 1'-0"uS4 4 MEZZANINE FLOOR CONNECTION