HomeMy WebLinkAboutFeature 45 - Powerhouse - file 3 of 3DATUM EL 0.00 Project No. H-332360Drawing No. 109-45-160 Rev. AREV. NO. DESCRIPTION DATE DESIGN ENGINEERDESIGNCHECKED BYDRAWN BY DRAWINGCHECKED BYDISCIPLINELEAD ENG.PROJECTENGINEERPROJECTMANAGERA ISSUED FOR BID04-16-12 G. HOLDEN J. COLEMAN J. COLEMAN G. HOLDEN G. HOLDEN P.R. RODRIGUE S.M. HART NOTE:BLUE LAKE EXPANSION PROJECTDrawing No. 109-45-160CITY & BOROUGH OF SITKA, ALASKALoad ListAdditional loads will be incorporated as KW are identified109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)Comments1.01.1Station Service Transformer SST1SST11247052-SST11200300.00402.301100402.3018.19392.31Dwg No. 109-45-107Raw Water Pumps Transformer RWPT3SST31247052-RWPT31200500.00670.501100670.5030.31653.85Dwg No. 109-45-111Sawmill Creek Industrial Park (SMCIP)SMCIP1247052-SMCIP12001BY CBS1.2Station Service Transformer SST2SST21247052-SST21200300.00402.301100402.3018.19392.31Dwg No. 109-45-107Blue Lake Switchyard Transformer T4T41247052-T41200TBA1Dwg No. 109-46-0212.02.1Old Blue Lake Hydro PlantOBLHP48052-SSB11800225300.00402.30150201.15236.22196.15Station HPU Control Panel BL#5BL548052-SSB1380012550.0067.0518053.6462.9952.31Station HPU Control Panel BL#4BL448052-SSB1480012550.0067.0518053.6462.9952.31480V Station Service Panelboard SSP1SSP148052-SSB17800400250.00335.25180268.20314.96261.54(BUS1) Dwg No. 109-45-109PANEL TOTAL308.43 362.20 300.772.2480V Station Service Panelboard SSP1SSP148052-SSB21800400250.00335.25180268.20314.96261.54(BUS2) Dwg No. 109-45-109Station HPU Control Panel BL#3BL348052-SSB2280012550.0067.0518053.6462.9952.31PANEL TOTAL321.84 377.95 313.85480V Station Service Bus SSB2 (Dwg No. 109-45-107)12.47-kV Switchgear 1/2 Load Summary:SWGR-1: Generation Bus 1 (Dwg No. 109-45-101)SWGR-2: Generation Bus 2 (Dwg No. 109-45-101)480V Switchgear SSB1/SSB2 Load Summary:480V Station Service Bus SSB1 (Dwg No. 109-45-107)Powerhouse109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)CommentsPowerhouse3.03.1Turbine No.3 HPU Pump No.1T3HPU1480CB11583.735.0011005.005.874.88Turbine No.3 HPU Pump No.2T3HPU2480CB21583.735.00100.000.000.00standbyTurbine No.3 Kidney Loop PumpT3HPU2480CB31580.370.5011000.500.580.48Turbine No.3 HPU Tank HeaterT3HPU2480CB41581.001.3411001.341.571.31PANEL TOTAL6.84 8.03 6.673.2Turbine No.4 HPU No.1T4HPU1480CB11583.735.0011005.005.874.88Turbine No.4 HPU No.2T4HPU2480CB21583.735.00100.000.000.00standbyTurbine No.4 Kidney Loop PumpT3HPU2480CB31580.370.5011000.500.580.48Turbine No.4 HPU Tank HeaterT3HPU2480CB41581.001.3411001.341.571.31PANEL TOTAL6.84 8.03 6.673.3Turbine No.5 HPU No.1T5HPU1480CB11583.735.0011005.005.874.88Turbine No.5 HPU No.2T5HPU2480CB21583.735.00100.000.000.00standbyTurbine No.5 Kidney Loop PumpT3HPU2480CB31580.370.5011000.500.580.48Turbine No.5 HPU Tank HeaterT3HPU2480CB41581.001.3411001.341.571.31PANEL TOTAL6.84 8.03 6.673.4Sub Feed to SSP2SSP24801200125.00167.631100167.63196.85163.46Sump PumpP-1A480303.735.0011005.005.874.88Duplex Control PanelSump PumpP-1B480N/A3.735.00100.000.000.00standby (pwr by Duplex Cntl Pnl)Sewage Lift PumpP-2A480202.243.0011003.003.522.93Duplex Control PanelSewage Lift PumpP-2B480N/A2.243.00100.000.000.00standby (pwr by Duplex Cntl Pnl)Powerhouse Exhaust FanEF-14805151.121.5011001.501.761.46Powerhouse Crane FeederPHCF48088042.5056.99152.853.352.78Air CompressorAC-148036011.1814.99110014.9917.6114.62Air CompressorAC-248046011.1814.99100.000.000.00standbyPowerhouse High Bay LightingSSP192779204.205.631804.5115.864.39Powerhouse High Bay LightingSSP11027710204.205.631804.5115.864.39Powerhouse High Bay LightingSSP11127711203.504.691803.7513.223.66Powerhouse High Bay LightingSSP11127712203.504.691803.7513.223.66Substation Control BuildingSCBT1480167515.0020.1218016.0918.9015.69Distribution TransformerBST1480194045.0060.3518048.2856.6947.08Distribution Pnlbd DP1PANEL TOTAL108.23 165.86 105.55480V Station Service Panelboard SSP1 (Dwg No. 109-45-109)480V Generator Station Service Panels Load Summary:27480V Generator Service Panel BL#5 (Dwg No. 109-45-107)480V Generator Service Panel BL#3 (Dwg No. 109-45-107)480V Generator Service Panel BL#4 (Dwg No. 109-45-107)109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)CommentsPowerhouse3.5Powerhouse Welding ReceptaclesWR1A,1B,1C48017038.0050.96152.552.992.4860A receptaclePowerhouse Welding ReceptaclesWR2A,2B48027038.0050.96152.552.992.4860A receptacleUnit HeaterUH-248032010.0013.4118010.7312.6010.46Unit HeaterUH-348042010.0013.4118010.7312.6010.46Unit HeaterUH-448052010.0013.4118010.7312.6010.46Unit HeaterUH-548062010.0013.4118010.7312.6010.46Unit HeaterUH-648072010.0013.4118010.7312.6010.46Unit HeaterUH-748082010.0013.4118010.7312.6010.46Unit HeaterUH-848092010.0013.4118010.7312.6010.46Unit HeaterUH-9480102010.0013.4118010.7312.6010.46Unit HeaterUH-10480112010.0013.4118010.7312.6010.46Unit HeaterUH-11480122010.0013.4118010.7312.6010.46Unit HeaterUH-12480132010.0013.4118010.7312.6010.46Air Handling Unit 1AHU-148015305.857.841806.287.376.12Heater Power SupplyAir Handling Unit 2AHU-2480162011.4015.2918012.2314.3611.93Heater Power SupplyAir Handling Unit 3AHU-3480172010.0013.4118010.7312.6010.46Unit Power SupplyAir Handling Unit 4AHU-4480182010.0013.4118010.7312.6010.46Unit Power SupplyWater HeaterWH-2480147018.00241409.668.677.20Building Service TransformerBST2480224030.0040.2318032.1837.7931.38Bldg Service Pnlbd LPAPANEL TOTAL172.72 200.17 166.22PANEL'S SSP1 & SSP2 TOTAL280.96 366.03 271.77480V Station Service Panelboard SSP2 (Dwg No. 109-45-110)109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)CommentsPowerhouse4.04.1Strainer Backwash MotorSTR-11202150.190.2511000.252.070.25Strainer Backwash MotorSTR-21204150.190.25100.000.000.00standbyNorth Garage Door1201150.190.251800.201.660.20South Garage Door1203150.190.251800.201.660.20Switchyard Control Panel1205150.190.251800.201.660.20Stand-By Generator Control Panel & HTRDG120825/27/2920TBD1100.000.000.00standbyWashroom Exhaust FanEF-21207150.240.321100.030.260.03Washroom Exhaust FanEF-31208150.050.071100.010.050.01Dryer2089/11304.506.031201.215.661.18Mezzanine Control Panel12013304.506.031201.219.811.18Water HeaterWH-120810/12203.004.021401.617.541.57Washing Machine12014151.301.741200.352.830.34Unit HeaterUH-120816/18404.005.361804.2920.124.18Air Handling Unit 1 (Control Power)AHU-112015150.190.251800.201.660.20Control PowerAir Handling Unit 2 (Control Power)AHU-212020150.190.251800.201.660.20Control PowerTransformer T1 (Control Power)T112017200.001800.000.000.00Control PowerTransformer T2 (Control Power)T212019200.001800.000.000.00Control PowerStove Exhaust Hood12021150.001800.000.000.00Air Fan TF-1TF-120822/24150.560.751800.602.820.59Battery Charger 1BCH120847/49404.506.0311006.0328.295.88Battery Charger 2BCH220851/53404.506.03100.000.000.00standbyInverter A20848/502011000.000.000.00A/B c/w Static Xfer SwInverter B20852/542011000.000.000.00A/B c/w Static Xfer SwPANEL TOTAL16.61 87.74 16.204.2Refrigerator, Break Room1201150.500.6711000.675.450.65Kitchen Stove1203/5400.801.071250.272.180.26Lighting Contactor 'LC1'1207150.050.071800.050.440.05Office Roof Area Lighting1209201.401.881801.5012.211.46Outdoor Receptacles12011200.000.00100.000.000.00Indoor Receptacles12013200.000.00100.000.000.00Indoor Receptacles12015200.000.00100.000.000.00Washroom Lighting EL.13.0012017150.700.941100.090.760.09Emergency Lighting EL.13.0012019150.070.091200.020.150.02Lighting Contactor 'LC2'12021150.050.071800.050.440.05Break & Control Room Lighting12023201.502.011801.6113.081.57Break & Control Room Lighting12025200.700.941800.756.100.73Senior Operator's Room Lighting12027200.400.541800.433.490.42Senior Operator's Room Lighting12029200.360.481800.393.140.38Senior Operator's Room Receptacles12031150.000.00100.000.000.00Senior Operator's Room Receptacles12033150.000.00100.000.000.00Building Service Panelboard LPA (Dwg No. 109-45-110)208/120V Building Service Load Summary: Building Service Panelboard DP1 (Dwg No. 109-45-109)109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)CommentsPowerhouseEmergency Lighting EL.27.001202150.050.0711000.070.540.07Outdoor Lighting1204200.901.211500.604.900.59Outdoor Receptacles1206200.000.00100.000.000.00Shop Area Lighting EL.13.001208201.702.281250.574.630.56Shop Area Lighting EL.13.0012010202.202.951250.745.990.72Indoor Receptacles EL.13.0012012200.000.00100.000.000.00Indoor Receptacles EL.13.0012014200.000.00100.000.000.00Break & Control Room Receptacles12016150.000.00100.000.000.00Break & Control Room Receptacles12018150.000.00100.000.000.00Break Room Over Counter Receptacles12020150.000.00100.000.000.00Break Room Over Counter Receptacles12022150.000.00100.000.000.00Common Room Lighting12024200.700.941250.231.910.23Common Room Lighting12026200.600.801250.201.630.20Common Room Receptacles12028150.000.00100.000.000.00Common Room Receptacles12030150.000.00100.000.000.00PANEL TOTAL8.25 67.04 8.045.05.112.47kV MV Switchgear125Vdc20Hold For loadInverter A/B c/w Static Xfer Sw125Vdc2x20Hold For loadT/G #3 CONTROL PANEL125Vdc20Hold For loadHPU #3 CONTROL PANEL125Vdc20Hold For loadT/G #4 CONTROL PANEL125Vdc20Hold For loadHPU #4 CONTROL PANEL125Vdc20Hold For loadT/G #5 CONTROL PANEL125Vdc20Hold For loadHPU #5 CONTROL PANEL125Vdc20Hold For loadSTAND-BY GENSET125Vdc20Hold For loadSWYD CONTROL PANEL125Vdc20Hold For loadMEZZ. LOCAL CONTROL PANEL125Vdc20Hold For loadPANEL TOTAL0.00 0.00 0.005.2Protective Relays120VAC15Hold For loadScada120VAC15Hold For loadFire Alarm Panel120VAC15Hold For loadGen. #3 Air Duct Actuator120VAC15Hold For loadGen. #4 Air Duct Actuator120VAC15Hold For loadGen. #5 Air Duct Actuator120VAC15Hold For loadPANEL TOTAL0.00 0.00 0.00125VDC Panelboard DP2 (Dwg No. 109-45-109)120VAC Panelboard DP3 (Dwg No. 109-45-109)125VDC Load Summary:109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)CommentsPowerhouse6.06.1NSRAA Pump No.1P-3A480CB-RWP217544.7460.00110060.0070.4658.51NSRAA Pump No.2P-3B480CB-RWP317544.7460.00100.000.000.00standbyPotable Water Pump No.1P-4A480CB-RWP4350149.14200.001100200.00234.86195.03Potable Water Pump No.2P-4B480CB-RWP5350149.14200.00100.000.000.00standbyWater Treatment PlantWTP480CB-RWP6225143.00191.76180153.41180.15149.60PANEL TOTAL413.40 485.47 403.147.0Fish Valve Unit Powerhouse (FVU)1247052-FVU1BY CBS7.1existing U/G vault & bus bars (JV)Fish Valve Generator TransformerExisting 124701500.002011.501801609.2072.741569.23(Dwg No. 109-46-022)USFS Campground Service TransformerExisting1247025.0033.5318026.821.2126.15Gate House Service (Transformer T5)T5(BY OTHERS)124705225.0033.5318026.821.2126.15(Dwg No. 109-26-100)8.08.1Inlet Valve HPUExisting208201.121.501801.205.631.17Drainage Pump No.1Existing208202.243.001802.4011.272.34Drainage Pump No.2Existing208202.243.00100.000.000.00StandbyUnit Heater 1UH12084010.0013.4118010.7350.3010.46Unit Heater 2UH22084010.0013.4118010.7350.3010.46New Exhaust FanEF208200.563.001802.4011.252.34HoistHST208200.751.00150.050.230.05Water HeaterWH208304.56.031402.4111.322.35Battery Charger 1BCH1208404.506.0311006.0328.295.88Battery Charger 2BCH2208404.506.03100.000.000.00StandbyInverter A/B c/w Static Xfer Sw1202x2011000.000.000.00Hold For loadThrust Bearing Air Blast MotorTBABM1204011000.000.000.00Hold For loadLighting cct A120201800.000.000.00Hold For loadLighting cct B120201800.000.000.00Hold For loadReceptacles cct A120201600.000.000.00Hold For loadReceptacles cct B120201600.000.000.00Hold For loadPANEL TOTAL32.35 151.69 31.55208/120V FVU Building Services Load Summary:Blue Lake Switchyard and Fish Valve Unit PowerhouseFVU Building Service Panelboard LPA (Dwg No. 109-46-022)Raw Water Pumps, 480V Switchgear RWP Load Summary:12.47-kV Blue Lake Switchyard Load Summary: (Dwg No. 109-46-021)12.47-kV Fish Valve Unit U/G Vault Bus (JV) (Dwg No. 109-46-021)480V Raw Water Pumps Bus (Dwg No. 109-45-111)109-45-160_Load List.xls4/16/2012 Project No.H-332360Drawing No. 109-45-160 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaItem Equipment Equipment Number Voltage (V)Breaker No. Breaker Size (A) (Frame)Breaker Size (A) (Trip)Nominal kW Nominal HP Quantity Demand Factor (%)Demand Load (HP)Demand Load (A)Demand Load (kVA)CommentsPowerhouse9.09.1Wicket GatesWG125200.560.751200.151.050.13Inlet ValveIV125200.560.75150.040.260.03Fish ValveFV125200.560.75150.040.260.03RecloserRECL12520150.000.000.00Hold For loadProtective Relays12520110.000.000.00Hold For loadInverter A/B c/w Static Xfer Sw1252x2011000.000.000.00Hold For loadPANEL TOTAL0.23 1.58 0.2010.010.1Fixed Wheel Gate HoistFWGH4804155.597.501201.501.761.46Unit HeaterUH-148023015.0013.4118010.7312.6010.46Unit HeaterUH-248033015.0013.4118010.7312.6010.46Air CompressorAC-14805155.5915.001507.508.817.31Spare (Future Air Compressor)AC-24806155.5915.00100.000.000.00Gatehouse Building Services GHSP148012207.5010.061808.059.457.85Bldg Service Pnlbd LPAPANEL TOTAL38.50 45.21 37.54208/120V Gate House Services Panelboard GHSP1 (Dwg No. 109-26-031)GATE HOUSE125VDC FVU Load Summary:208/120V Gate House Services Load Summary:125VDC Panelboard DP1 (Dwg No. 109-46-022)109-45-160_Load List.xls4/16/2012 Project No. H-332360Drawing No. 109-45-170 Rev. AREV. NO. DESCRIPTION DATE DESIGN ENGINEERDESIGNCHECKED BYDRAWN BY DRAWINGCHECKED BYDISCIPLINELEAD ENG.PROJECTENGINEERPROJECTMANAGERA ISSUED FOR BID03-23-12 G. HOLDEN J. COLEMAN J. COLEMAN G. HOLDEN G. HOLDEN P.R. RODRIGUE S.M. HART BLUE LAKE EXPANSION PROJECTConduit ScheduleDrawing No. 109-45-170CITY & BOROUGH OF SITKA, ALASKA109-45-170_Conduit Schedule.xls3/23/2012 Project No. H-332360Drawing No. 106-45-170 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaSIZE TYPE LENGTH PURPOSEin FeetDESCRIPTION DWG. No. DESCRIPTION DWG. No.4" RGS 25 15kV PWR GENERATOR LINE CUBICAL UNIT 3109-45-120 COLUMN LINES 'D7', EL.23'-10"109-45-120 FEEDER CABLE VIA 15kV TRAY FROM SWGR BKR (GILKES ITEM 1)4" RGS 25 15kV PWR GENERATOR LINE CUBICAL UNIT 3109-45-120 COLUMN LINES 'D7', EL.23'-10"109-45-120 FEEDER CABLE VIA 15kV TRAY FROM SWGR BKR (GILKES ITEM 1)2" RGS 20 CNTL GENERATOR LINE CUBICAL UNIT 3 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 SPACE HEATER (GILKES ITEM 1)2" RGS 20 CNTL GENERATOR LINE CUBICAL UNIT 3 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 SPARE2" RGS 15 CNTL GENERATOR EXCITER UNIT 3109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 EXCITER FIELD LEADS (GILKES ITEM 7)2" RGS 15 CNTL GENERATOR EXCITER UNIT 3109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 MAGNETIC ALTERNATOR LEADS (GILKES ITEM 8)2" RGS 30 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 (GILKES ITEM 12, 13 & 17)2" RGS 30 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 (GILKES ITEM 11, & 18)2" RGS 30 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 (GILKES ITEM 3, 4 & 5)2" RGS 30 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 SPARE2" RGS 30 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 3 EXCITER/BRAKE/ODE ACCESSORY BOX 109-45-120 (GILKES ITEM 12 & 17)2" RGS 30 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 3 EXCITER/BRAKE/ODE ACCESSORY BOX 109-45-120 (GILKES ITEM 11 & 18)1" RGS 10 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 3 DE BEARING ACCESSORY BOX 109-45-120 (GILKES ITEM 11)1" RGS 10 CNTL GENERATOR UNIT 3 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 3 DE BEARING ACCESSORY BOX 109-45-120 (GILKES ITEM 13)2" RGS 30 PWR GENERATOR UNIT 3 FRAME & CORE 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 SPARE2" RGS 40 PWR GENERATOR UNIT 3 FRAME & CORE 109-45-120 UNIT 3 HPU CONTROL PANEL109-45-120 FRAME SPACE HEATER LEADS (GILKES ITEM 6)2" RGS 25 CNTL GENERATOR CONTROL PANEL UNIT 3 109-45-120GENERATOR UNIT 3 DE BEARING VIBRATION SWITCH 109-45-120 (GILKES ITEM 14)2" RGS 40 CNTL GENERATOR CONTROL PANEL UNIT 3 109-45-120GENERATOR UNIT 3 ODE BEARING VIBRATION SWITCH 109-45-120 (GILKES ITEM 14)2" RGS 40 CNTL UNIT 3 TURBINE TERMINAL BOX 1109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 3 TURBINE TERMINAL BOX 1109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 3 TURBINE TERMINAL BOX 2109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 3 TURBINE TERMINAL BOX 2109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 30 CNTL GENERATOR NEUTRAL CUBICAL UNIT 3 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 GENERATOR LEAD CT'S (GILKES ITEM 2)2" RGS 30 CNTL GENERATOR NEUTRAL CUBICAL UNIT 3 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 3 109-45-120 NEUTRAL CT & SPACE HEATER (GILKES ITEM 2)2" RGS 30 NEUTRAL GENERATOR NEUTRAL CUBICAL UNIT 3 109-45-120 GROUNDING RESISTOR CUBICAL UNIT 3 109-45-120 (GILKES ITEM 2)2" RGS 30 NEUTRAL GENERATOR NEUTRAL CUBICAL UNIT 3 109-45-120 GROUNDING RESISTOR CUBICAL UNIT 3 109-45-120 SPARE2" RGS 25 CNTL GENERATOR CONTROL PANEL UNIT 3 109-45-120GENERATOR CONTROL PANEL UNIT 4 109-45-1202" RGS 25 COMM GENERATOR CONTROL PANEL UNIT 3 109-45-120GENERATOR CONTROL PANEL UNIT 4 109-45-1204" RGS 25 15kV PWR GENERATOR LINE CUBICAL UNIT 4109-45-120 COLUMN LINES 'D5', EL.23'-10"109-45-120 FEEDER CABLE VIA 15kV TRAY FROM SWGR BKR (GILKES ITEM 1)4" RGS 25 15kV PWR GENERATOR LINE CUBICAL UNIT 4109-45-120 COLUMN LINES 'D5', EL.23'-10"109-45-120 FEEDER CABLE VIA 15kV TRAY FROM SWGR BKR (GILKES ITEM 1)2" RGS 20 CNTL GENERATOR LINE CUBICAL UNIT 4 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 SPACE HEATER (GILKES ITEM 1)2" RGS 20 CNTL GENERATOR LINE CUBICAL UNIT 4 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 SPARE2" RGS 15 CNTL GENERATOR EXCITER UNIT 4109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 EXCITER FIELD LEADS (GILKES ITEM 7)2" RGS 15 CNTL GENERATOR EXCITER UNIT 4109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 MAGNETIC ALTERNATOR LEADS (GILKES ITEM 8)2" RGS 30 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 (GILKES ITEM 12, 13 & 17)2" RGS 30 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 (GILKES ITEM 11, & 18)2" RGS 30 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 (GILKES ITEM 3, 4 & 5)2" RGS 30 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 SPARE2" RGS 30 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 4 EXCITER/BRAKE/ODE ACCESSORY BOX 109-45-120 (GILKES ITEM 12 & 17)2" RGS 30 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 4 EXCITER/BRAKE/ODE ACCESSORY BOX 109-45-120 (GILKES ITEM 11 & 18)1" RGS 10 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 4 DE BEARING ACCESSORY BOX 109-45-120 (GILKES ITEM 11)1" RGS 10 CNTL GENERATOR UNIT 4 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 4 DE BEARING ACCESSORY BOX 109-45-120 (GILKES ITEM 13)2" RGS 30 PWR GENERATOR UNIT 4 FRAME & CORE 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 SPARE2" RGS 40 PWR GENERATOR UNIT 4 FRAME & CORE 109-45-120 UNIT 4 HPU CONTROL PANEL109-45-120 FRAME SPACE HEATER LEADS (GILKES ITEM 6)2" RGS 25 CNTL GENERATOR CONTROL PANEL UNIT 4 109-45-120GENERATOR UNIT 4 DE BEARING VIBRATION SWITCH 109-45-120 (GILKES ITEM 14)2" RGS 40 CNTL GENERATOR CONTROL PANEL UNIT 4 109-45-120GENERATOR UNIT 4 ODE BEARING VIBRATION SWITCH 109-45-120 (GILKES ITEM 14)2" RGS 40 CNTL UNIT 4 TURBINE TERMINAL BOX 1109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 4 TURBINE TERMINAL BOX 1109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 4 TURBINE TERMINAL BOX 2109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 4 TURBINE TERMINAL BOX 2109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 30 CNTL GENERATOR NEUTRAL CUBICAL UNIT 4 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 GENERATOR LEAD CT'S (GILKES ITEM 2)2" RGS 30 CNTL GENERATOR NEUTRAL CUBICAL UNIT 4 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 4 109-45-120 NEUTRAL CT & SPACE HEATER (GILKES ITEM 2)2" RGS 30 NEUTRAL GENERATOR NEUTRAL CUBICAL UNIT 4 109-45-120 GROUNDING RESISTOR CUBICAL UNIT 4 109-45-120 (GILKES ITEM 2)2" RGS 30 NEUTRAL GENERATOR NEUTRAL CUBICAL UNIT 4 109-45-120 GROUNDING RESISTOR CUBICAL UNIT 4 109-45-120 SPARE2" RGS 25 CNTL GENERATOR CONTROL PANEL UNIT 4 109-45-120GENERATOR CONTROL PANEL UNIT 5 109-45-1202" RGS 25 COMM GENERATOR CONTROL PANEL UNIT 4 109-45-120GENERATOR CONTROL PANEL UNIT 5 109-45-120BLUE LAKE EXPANSION PROJECT - Conduit ScheduleGENERATOR No.3 EMBEDDED CONDUITSGENERATOR No.4 EMBEDDED CONDUITSDrawing No. 109-45-170REVREMARKSFROMTO109-45-170_Conduit Schedule.xls3/23/2012 Project No. H-332360Drawing No. 106-45-170 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaSIZE TYPE LENGTH PURPOSEin FeetDESCRIPTION DWG. No. DESCRIPTION DWG. No.BLUE LAKE EXPANSION PROJECT - Conduit ScheduleGENERATOR No.3 EMBEDDED CONDUITSDrawing No. 109-45-170REVREMARKSFROMTO4" RGS 25 15kV PWR GENERATOR LINE CUBICAL UNIT 5109-45-120 COLUMN LINES 'D3', EL.23'-10"109-45-120 FEEDER CABLE VIA 15kV TRAY FROM SWGR BKR (GILKES ITEM 1)4" RGS 25 15kV PWR GENERATOR LINE CUBICAL UNIT 5109-45-120 COLUMN LINES 'D3', EL.23'-10"109-45-120 FEEDER CABLE VIA 15kV TRAY FROM SWGR BKR (GILKES ITEM 1)2" RGS 20 CNTL GENERATOR LINE CUBICAL UNIT 5 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 SPACE HEATER (GILKES ITEM 1)2" RGS 20 CNTL GENERATOR LINE CUBICAL UNIT 5 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 SPARE2" RGS 15 CNTL GENERATOR EXCITER UNIT 5109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 EXCITER FIELD LEADS (GILKES ITEM 7)2" RGS 15 CNTL GENERATOR EXCITER UNIT 5109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 MAGNETIC ALTERNATOR LEADS (GILKES ITEM 8)2" RGS 30 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 (GILKES ITEM 12, 13 & 17)2" RGS 30 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 (GILKES ITEM 11, & 18)2" RGS 30 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 (GILKES ITEM 3, 4 & 5)2" RGS 30 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 SPARE2" RGS 30 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 5 EXCITER/BRAKE/ODE ACCESSORY BOX 109-45-120 (GILKES ITEM 12 & 17)2" RGS 30 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 5 EXCITER/BRAKE/ODE ACCESSORY BOX 109-45-120 (GILKES ITEM 11 & 18)1" RGS 10 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 5 DE BEARING ACCESSORY BOX 109-45-120 (GILKES ITEM 11)1" RGS 10 CNTL GENERATOR UNIT 5 MARSHALLING CUBICLE 109-45-120 GENERATOR UNIT 5 DE BEARING ACCESSORY BOX 109-45-120 (GILKES ITEM 13)2" RGS 30 PWR GENERATOR UNIT 5 FRAME & CORE 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 SPARE2" RGS 40 PWR GENERATOR UNIT 5 FRAME & CORE 109-45-120 UNIT 5 HPU CONTROL PANEL109-45-120 FRAME SPACE HEATER LEADS (GILKES ITEM 6)2" RGS 25 CNTL GENERATOR CONTROL PANEL UNIT 5 109-45-120GENERATOR UNIT 5 DE BEARING VIBRATION SWITCH 109-45-120 (GILKES ITEM 14)2" RGS 40 CNTL GENERATOR CONTROL PANEL UNIT 5 109-45-120GENERATOR UNIT 5 ODE BEARING VIBRATION SWITCH 109-45-120 (GILKES ITEM 14)2" RGS 40 CNTL UNIT 5 TURBINE TERMINAL BOX 1109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 5 TURBINE TERMINAL BOX 1109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 5 TURBINE TERMINAL BOX 2109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 40 CNTL UNIT 5 TURBINE TERMINAL BOX 2109-45-120 COLUMN LINE 'D' EL.23'-10"109-45-120 (GILKES DWG.141493)2" RGS 30 CNTL GENERATOR NEUTRAL CUBICAL UNIT 5 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 GENERATOR LEAD CT'S (GILKES ITEM 2)2" RGS 30 CNTL GENERATOR NEUTRAL CUBICAL UNIT 5 TERMINAL BOX 109-45-120 GENERATOR CONTROL PANEL UNIT 5 109-45-120 NEUTRAL CT & SPACE HEATER (GILKES ITEM 2)2" RGS 30 NEUTRAL GENERATOR NEUTRAL CUBICAL UNIT 5 109-45-120 GROUNDING RESISTOR CUBICAL UNIT 5 109-45-120 (GILKES ITEM 2)2" RGS 30 NEUTRAL GENERATOR NEUTRAL CUBICAL UNIT 5 109-45-120 GROUNDING RESISTOR CUBICAL UNIT 5 109-45-120 SPAREGENERATOR No.5 EMBEDDED CONDUITS109-45-170_Conduit Schedule.xls3/23/2012 Project No. H-332360Drawing No. 106-45-170 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaSIZE TYPE LENGTH PURPOSEin FeetDESCRIPTION DWG. No. DESCRIPTION DWG. No.BLUE LAKE EXPANSION PROJECT - Conduit ScheduleGENERATOR No.3 EMBEDDED CONDUITSDrawing No. 109-45-170REVREMARKSFROMTO4" RGS 15kV PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T1' FEEDER CABLE T152T1-P1 A/B/C4" RGS 15kV PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T1' FEEDER CABLE T152T1-P2 A/B/C4" RGS PWR & CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T1' PWR/CNTL CABLES4" RGS PWR & CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T1' PWR/CNTL CABLES4" RGS 15kV PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T2' FEEDER CABLE T252T2-P1 A/B/C4" RGS 15kV PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T2' FEEDER CABLE T252T2-P2 A/B/C4" RGS PWR & CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T2' PWR/CNTL CABLES4" RGS PWR & CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T2' PWR/CNTL CABLES4" RGS 15kV PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 TRANSFORMER 'T4' FEEDER CABLE 52T4T4-P1 A/B/C4" RGS 15kV PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 SMCIP FEEDER CABLE 52SMCIP-P1 A/B/C4" RGS 480V PWR BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 BLHP FEEDER CABLE CBSSB110BLHP-P14" RGS CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 OLD B.L. PWRHSE CONTROL CABLES4" RGS CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 SUBSTATION PWR/CONTROL CABLES4" RGS CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 SUBSTATION PWR/CONTROL CABLES4" RGS CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 SUBSTATION PWR/CONTROL CABLES4" RGS CNTL BLU POWERHOUSE BETWEEN COLUMN LINES 'A5' & 'A6', EL.24'-0"109-45-120 & 109-55-003EXISTING POWERHOUSE OUTSIDE WALL SOUTHEAST CORNER 109-55-003 SUBSTATION PWR/CONTROL CABLES4" RGS 12 480V PWR BETWEEN COLUMN LINES 'A3' & 'A4', EL.26'-3 1/2" 109-45-120 STATION SERVICE DIESEL GENERATOR 'DG1' 109-45-1204" RGS 12 480V PWR BETWEEN COLUMN LINES 'A3' & 'A4', EL.26'-3 1/2" 109-45-120 STATION SERVICE DIESEL GENERATOR 'DG1' 109-45-1204" RGS 12 CNTL BETWEEN COLUMN LINES 'A3' & 'A4', EL.26'-3 1/2" 109-45-120 STATION SERVICE DIESEL GENERATOR 'DG1' 109-45-1204" RGS 12 CNTL BETWEEN COLUMN LINES 'A3' & 'A4', EL.26'-3 1/2" 109-45-120 STATION SERVICE DIESEL GENERATOR 'DG1' 109-45-1204" RGS 20 15kV PWR 12.47kV SWGR BREAKER '52-SST1', BUS 1 (PRIMARY FEEDER) 109-45-120 STATION SERVICE TRANSFORMER 'SST1' 109-45-1204" RGS 20 15kV PWR 12.47kV SWGR BREAKER '52-SST1', BUS 1 (PRIMARY FEEDER) 109-45-120 STATION SERVICE TRANSFORMER 'SST1' 109-45-1204" RGS 15 480V PWR STATION SERVICE TRANSFORMER 'SST1' (SECONDARY FEEDER) 109-45-120 STATION SERVICE 480V DISTRIBUTION SWITCHGEAR 'SSB1' 109-45-1204" RGS 15 480V PWR STATION SERVICE TRANSFORMER 'SST1' (SECONDARY FEEDER) 109-45-120 STATION SERVICE 480V DISTRIBUTION SWITCHGEAR 'SSB1' 109-45-1204" RGS 40 15kV PWR 12.47kV SWGR BREAKER '52-SST2', BUS 2 (PRIMARY FEEDER) 109-45-120 STATION SERVICE TRANSFORMER 'SST2' 109-45-1204" RGS 40 15kV PWR 12.47kV SWGR BREAKER '52-SST2', BUS 2 (PRIMARY FEEDER) 109-45-120 STATION SERVICE TRANSFORMER 'SST2' 109-45-1204" RGS 40 480V PWR STATION SERVICE TRANSFORMER 'SST2' (SECONDARY FEEDER) 109-45-120 STATION SERVICE 480V DISTRIBUTION SWITCHGEAR 'SSB2' 109-45-1204" RGS 40 480V PWR STATION SERVICE TRANSFORMER 'SST2' (SECONDARY FEEDER) 109-45-120 STATION SERVICE 480V DISTRIBUTION SWITCHGEAR 'SSB2' 109-45-1202" RGS 5 PWR COLUMN LINE 'A5', EL.22'-2"109-45-120 LIFT STATION DUPLEX PUMP CONTROLLER 109-45-1202" RGS 5 CNTL COLUMN LINE 'A5', EL.22'-2"109-45-120 LIFT STATION DUPLEX PUMP CONTROLLER 109-45-1202" RGS 15 PWR LIFT STATION DUPLEX PUMP CONTROLLER 109-45-120 LIFT STATION109-45-1202" RGS 15 CNTL LIFT STATION DUPLEX PUMP CONTROLLER 109-45-120 LIFT STATION109-45-1204" RGS 40 15kV PWR 12.47kV SWGR BREAKER '52-RWPT3', BUS 1 (PRIMARY FEEDER) 109-45-120 RAW WATER PUMP TRANSFORMER 'RWPT3' 109-45-1204" RGS 40 15kV PWR 12.47kV SWGR BREAKER '52-RWPT3', BUS 1 (PRIMARY FEEDER) 109-45-120 RAW WATER PUMP TRANSFORMER 'RWPT3' 109-45-1204" RGS 30 480V PWRRAW WATER PUMP TRANSFORMER 'RWPT3' (SECONDARY FEEDER)109-45-120 480V CABLE TRAY COLUMN LINE 'B8', EL.25'-0" 109-45-120 FEEDER CABLE VIA 480V TRAY FROM 'RWP' 480V MCC4" RGS 30 480V PWRRAW WATER PUMP TRANSFORMER 'RWPT3' (SECONDARY FEEDER)109-45-120 480V CABLE TRAY COLUMN LINE 'B8', EL.25'-0" 109-45-120 FEEDER CABLE VIA 480V TRAY FROM 'RWP' 480V MCC2" RGS 8 480V PWR COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP AREA109-45-120, & 1222" RGS 8 480V PWR COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP AREA109-45-120, & 1222" RGS 8 480V PWR COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP AREA109-45-120, & 1224" RGS 8 480V PWR COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP AREA109-45-120, & 1222" RGS 8 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP AREA109-45-120, & 1222" RGS 8 INSTR. COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP AREA109-45-120, & 1222" RGS 5 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP LOCAL CNTL PNL '1A' 109-45-120, & 1222" RGS 5 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP LOCAL CNTL PNL '1A' 109-45-120, & 1222" RGS 5 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP LOCAL CNTL PNL '1A' 109-45-120, & 1222" RGS 5 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 RAW WATER PUMP LOCAL CNTL PNL '1A' 109-45-120, & 1222" RGS 5 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 POTABLE WATER PUMP No. P-4A PUSHBUTTON STN 109-45-120, & 1222" RGS 5 CNTL COLUMN LINE 'D8', EL.24'-7 3/4"109-45-120 POTABLE WATER PUMP No. P-4B PUSHBUTTON STN 109-45-120, & 122MISC. CONDUITS109-45-170_Conduit Schedule.xls3/23/2012 Project No. H-332360Drawing No. 106-45-170 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaSIZE TYPE LENGTH PURPOSEin FeetDESCRIPTION DWG. No. DESCRIPTION DWG. No.BLUE LAKE EXPANSION PROJECT - Conduit ScheduleGENERATOR No.3 EMBEDDED CONDUITSDrawing No. 109-45-170REVREMARKSFROMTO4" RGS 15kV PWR EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T1' FEEDER CABLE T152T1-P1 A/B/C4" RGS 15kV PWR EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T1' FEEDER CABLE T152T1-P2 A/B/C4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T1' PWR/CNTL CABLES4" RGS 15kV PWR EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T2' FEEDER CABLE T252T2-P1 A/B/C4" RGS 15kV PWR EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T2' FEEDER CABLE T252T2-P2 A/B/C4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T2' PWR/CNTL CABLES4" RGS 15kV PWR EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T4' FEEDER CABLE 52T4T4-P1 A/B/C4" RGS SPARE EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CABLE PULL BOX109-55-0024" RGS 15kV PWR SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T1' SECONDDARY CONNECTION BOX 109-55-002 TRANSFORMER 'T1' FEEDER CABLE T152T1-P1 A/B/C4" RGS 15kV PWR SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T1' SECONDDARY CONNECTION BOX 109-55-002 TRANSFORMER 'T1' FEEDER CABLE T152T1-P2 A/B/C4" RGS PWR & CNTL SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T1' CONTROL PANEL 109-55-002 TRANSFORMER 'T1' PWR/CNTL CABLES4" RGS 15kV PWR SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T2' SECONDDARY CONNECTION BOX 109-55-002 TRANSFORMER 'T2' FEEDER CABLE T252T2-P1 A/B/C4" RGS 15kV PWR SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T2' SECONDDARY CONNECTION BOX 109-55-002 TRANSFORMER 'T2' FEEDER CABLE T252T2-P2 A/B/C4" RGS PWR & CNTL SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T2' CONTROL PANEL 109-55-002 TRANSFORMER 'T2' PWR/CNTL CABLES4" RGS 15kV PWR SUBSTATION CABLE PULL BOX109-55-002 TRANSFORMER 'T4'109-55-002 TRANSFORMER 'T4' FEEDER CABLE 52T4T4-P1 A/B/C4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CONTROL PANEL109-55-002 TRANSFORMER 'T1' PWR/CNTL CABLES4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CONTROL PANEL109-55-002 TRANSFORMER 'T2' PWR/CNTL CABLES4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CONTROL PANEL109-55-002 SUBSTATION PWR/CONTROL CABLES4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CONTROL PANEL109-55-002 SUBSTATION PWR/CONTROL CABLES4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CONTROL PANEL109-55-002 SUBSTATION PWR/CONTROL CABLES4" RGS PWR & CNTL EXISTING POWERHOUSE OUTSIDE WALL SOUTHWEST CORNER 109-55-002 SUBSTATION CONTROL PANEL109-55-002 SUBSTATION PWR/CONTROL CABLES2" RGS CNTL EXISTING 2" CONDUIT FROM BKR 22 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 22 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 22 109-55-002 SUBSTATION CONTROL PANEL109-55-0024" RGS CNTL TRANSFORMER 'T1' CONTROL PANEL 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 55 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 55 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 55 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 33 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 33 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING 2" CONDUIT FROM BKR 33 109-55-002 SUBSTATION CONTROL PANEL109-55-0024" RGS CNTL TRANSFORMER 'T2' CONTROL PANEL 109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL TRANSFORMER 'T4'109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL RELOCATED BUS VT PHASE A/B109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL RELOCATED BUS VT PHASE B/C109-55-002 SUBSTATION CONTROL PANEL109-55-0022" RGS CNTL EXISTING LINE VT COLUMN D2109-55-002 SUBSTATION CONTROL PANEL109-55-002SUBSTATION CONDUITS109-45-170_Conduit Schedule.xls3/23/2012 Project No. H-332360Drawing No. 109-45-180 Rev. AREV. NO. DESCRIPTION DATE DESIGN ENGINEERDESIGNCHECKED BYDRAWN BY DRAWINGCHECKED BYDISCIPLINELEAD ENG.PROJECTENGINEERPROJECTMANAGERA ISSUED FOR BID04-16-12 G. HOLDEN J. COLEMAN J. COLEMAN G. HOLDEN G. HOLDEN P.R. RODRIGUE S.M. HART BLUE LAKE EXPANSION PROJECTDrawing No. 109-45-180CITY & BOROUGH OF SITKA, ALASKACable Schedule109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No. DESCRIPTION DWG. No. ROUTEPOWERHOUSET152T1-P1 A/B/C 3-1c-350MCM PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-T1 109-45-101 TRANSFORMER T1 SECONDARY SIDE CONNECTION 109-45-101 1-4" CONDUIT & 15kV TRAYT152T1-P2 A/B/C 3-1c-350MCM PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-T1 109-45-101 TRANSFORMER T1 SECONDARY SIDE CONNECTION 109-45-101 1-4" CONDUIT & 15kV TRAY52SST1SST1-P1 1-3C#2 PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-SST1 109-45-101 STATION SERVICE TRANSFORMER SST1 109-45-107 1-4" CONDUIT52RWPT3RWPT3-P1 1-3C#2 PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-RWPT3 109-45-101 RAW WATER PUMPS TRANSFORMER RWPT3 109-45-111 1-4" CONDUIT52SMCIP-P1 3-1c-350MCM PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-SCIP 109-45-101 EXISTING TOWER FOR OVERHEAD LINE TO SCIP 109-55-002 1-4" CONDUIT & 15kV TRAY52G4G4-P1 A/B/C 3-1C#4/0 PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-G4 109-45-101 GENERATOR LINE CUBICLE UNIT 4 109-45-102 1-4" CONDUIT & 15kV TRAY (GILKES ITEM 1 DWG.430550-F22 &14DSB-2557)52G4G4-P2 A/B/C 3-1C#4/0 PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-G4 109-45-101 GENERATOR LINE CUBICLE UNIT 4 109-45-102 1-4" CONDUIT & 15kV TRAY (GILKES ITEM 1 DWG.430550-F22 &14DSB-2557)52G5G5-P1 A/B/C 3-1C#4/0 PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-G5 109-45-101 GENERATOR LINE CUBICLE UNIT 5 109-45-102 1-4" CONDUIT & 15kV TRAY (GILKES ITEM 1 DWG.430550-F22 &14DSB-2557)52G5G5-P2 A/B/C 3-1C#4/0 PWR 15kV 15kV SWITCHGEAR 1, BUS 1, BKR 52-G5 109-45-101 GENERATOR LINE CUBICLE UNIT 5 109-45-102 1-4" CONDUIT & 15kV TRAY (GILKES ITEM 1 DWG.430550-F22 &14DSB-2557)FROMTOREMARKS REVBLUE LAKE EXPANSION PROJECT - Cable Schedule - 15kV cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGET252T2-P1 A/B/C 3-1c-350MCM PWR 15kV 15kV SWITCHGEAR 2, BUS 2, BKR 52-T2 109-45-101 TRANSFORMER T2 SECONDARY SIDE CONNECTION 109-45-101 1-4" CONDUIT & 15kV TRAYT252T2-P2 A/B/C 3-1c-350MCM PWR 15kV 15kV SWITCHGEAR 2, BUS 2, BKR 52-T2 109-45-101 TRANSFORMER T2 SECONDARY SIDE CONNECTION 109-45-101 1-4" CONDUIT & 15kV TRAY52SST2SST2-P1 3-1C#2 PWR 15kV 15kV SWITCHGEAR 2, BUS 2, BKR 52-SST2 109-45-101 STATION SERVICE TRANSFORMER SST2 109-45-107 1-4" CONDUIT52T4T4-P1 3-1C-350MCM PWR 15kV 15kV SWITCHGEAR 2, BUS 2, BKR 52-T4 109-45-101 BLUE LAKE SWITCHYARD TRANSFORMER T4 109-46-021 1-4" CONDUIT52G3G3-P1 A/B/C 3-1C#4/0 PWR 15kV 15kV SWITCHGEAR 2, BUS 2, BKR 52-G3 109-45-101 GENERATOR LINE CUBICLE UNIT 3 109-45-102 1-4" CONDUIT & 15kV TRAY (GILKES ITEM 1 DWG.430550-F22 &14DSB-2557)52G3G3-P2 A/B/C 3-1C#4/0 PWR 15kV 15kV SWITCHGEAR 2, BUS 2, BKR 52-G3 109-45-101 GENERATOR LINE CUBICLE UNIT 3 109-45-102 1-4" CONDUIT & 15kV TRAY (GILKES ITEM 1 DWG.430550-F22 &14DSB-2557)G3RESISTOR-P1 1-1C#2/0 PWR 15kV GENERATOR NEUTRAL CUBICLE UNIT 3 109-45-102 GROUNDING RESISTOR CUBICLE UNIT 3 109-45-102 1-2" CONDUIT (GILKES ITEM 2 DWG.430550-F22 &14DSB-2558)G3-GND 1-1C#2/0PWR15kV GROUNDING RESISTOR CUBICLE UNIT 3 109-45-102 GENERATOR 3 GROUND 109-45-102 CONNECTED TO GND GRIDG4RESISTOR-P1 1-1C#2/0 PWR 15kV GENERATOR NEUTRAL CUBICLE UNIT 4 109-45-102 GROUNDING RESISTOR CUBICLE UNIT 4 109-45-102 1-2" CONDUIT (GILKES ITEM 2 DWG.430550-F22 &14DSB-2558)G4-GND 1-1C#2/0 PWR 15kV GROUNDING RESISTOR CUBICLE UNIT 4 109-45-102 GENERATOR 4 GROUND 109-45-102 CONNECTED TO GND GRIDG5RESISTOR-P1 1-1C#2/0 PWR 15kV GENERATOR NEUTRAL CUBICLE UNIT 5 109-45-102 GROUNDING RESISTOR CUBICLE UNIT 5 109-45-102 1-2" CONDUIT (GILKES ITEM 2 DWG.430550-F22 &14DSB-2558)G5-GND 1-1C#2/0 PWR 15kV GROUNDING RESISTOR CUBICLE UNIT 5 109-45-102 GENERATOR 5 GROUND 109-45-102 CONNECTED TO GND GRID109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No. DESCRIPTION DWG. No. ROUTEPOWERHOUSESST1CBSST1-P1 1-4C#350MCM PWR 600VSTATION SERVICE TRANSFORMER SST1109-45-107480V SWITCHGEAR SSB1, BKR CB-SST1109-45-1071-4" CONDUITSST1CBSST1-P2 1-4C#350MCM PWR 600VSTATION SERVICE TRANSFORMER SST1109-45-107480V SWITCHGEAR SSB1, BKR CB-SST1109-45-1071-4" CONDUITSST2CBSST2-P1 1-4C#350MCM PWR 600VSTATION SERVICE TRANSFORMER SST2109-45-107480V SWITCHGEAR SSB2, BKR CB-SST2109-45-1071-4" CONDUITSST2CBSST2-P2 1-4C#350MCM PWR 600VSTATION SERVICE TRANSFORMER SST2109-45-107480V SWITCHGEAR SSB2, BKR CB-SST2109-45-1071-4" CONDUITCBSSB11OBLHP-P1 1-3C#2/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB11109-45-107OLD BLUE LAKE HYDRO PLANT109-55-0021-4" CONDUIT & 480V CABLE TRAYCBSSB11OBLHP-P2 1-3C#2/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB11109-45-107OLD BLUE LAKE HYDRO PLANT109-55-0021-4" CONDUIT & 480V CABLE TRAYCBSSB13BL5-P1 1-3C#1/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB13109-45-107STATION HPU SERVICE PANEL B.L.#5109-45-107480V CABLE TRAYCBSSB14BL4-P1 1-3C#1/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB14109-45-107STATION HPU SERVICE PANEL B.L.#4109-45-107480V CABLE TRAYCBSSB16DG1-P1 1-3C#2/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB16109-45-107STATION SERVICE DIESEL GENERATOR DG1109-45-1072-4" CONDUIT & 480V CABLE TRAYCBSSB16DG1-P2 1-3C#2/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB16109-45-107STATION SERVICE DIESEL GENERATOR DG1109-45-1072-4" CONDUIT & 480V CABLE TRAYCBSSB16DG1-N 1-1C#2/0 PWR 600V480V SWITCHGEAR SSB1, BKR CB-SSB16109-45-107STATION SERVICE DIESEL GENERATOR DG1109-45-1072-4" CONDUIT & 480V CABLE TRAYGENERATOR NEUTRALCBSSB17SSP1-P11-4C#350MCMPWR600V480V SWITCHGEAR SSB1, BKR CB-SSB17109-45-107480V STATION SERVICE PANELBOARD SSP1109-45-109480V CABLE TRAYBUS 1 FEEDER TO SSP1BLUE LAKE EXPANSION PROJECT - Cable Schedule - 600V power cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGEFROMTOREMARKS REVCBSSB17SSP1-P11-4C#350MCMPWR600V480V SWITCHGEAR SSB1, BKR CB-SSB17109-45-107480V STATION SERVICE PANELBOARD SSP1109-45-109480V CABLE TRAYBUS 1 FEEDER TO SSP1CBSSB21SSP1-P1 1-4C#350MCM PWR 600V480V SWITCHGEAR SSB2, BKR CB-SSB21109-45-107480V SWITCHGEAR SSB1, BKR CB-SSB17109-45-107480V CABLE TRAYBUS 2 FEEDER TO SSP1CBSSB22BL3-P1 3C#1/0 PWR 600V480V SWITCHGEAR SSB2, BKR CB-SSB22109-45-107STATION HPU SERVICE PANEL B.L.#3109-45-107480V CABLE TRAYBL3T3HPU1-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#3109-45-107HPU UNIT 3 PUMP No.1 DISCONNECT SWITCH109-45-107BL3T3HPU2-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#3109-45-107HPU UNIT 3 PUMP No.2 DISCONNECT SWITCH109-45-107BL3T3HPUKL-P1 3C#12 PWR 600V STATION HPU SERVICE PANEL B.L.#3 109-45-107 HPU UNIT 3 KIDNEY LOOP PUMP DISCONNECT SW. 109-45-107BL3T3HPUHTR-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#3109-45-107HPU UNIT 3 TANK HEATER DISCONNECT SW.109-45-107BL3-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#3430550-F22TURBINE GENERATOR G3 SPACE HEATER LEADS430550-F222" CONDUIT(GILKES ITEM 8)BL4T4HPU1-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#4109-45-107HPU UNIT 4 PUMP No.1 DISCONNECT SWITCH109-45-107BL4T4HPU2-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#4109-45-107HPU UNIT 4 PUMP No.2 DISCONNECT SWITCH109-45-107BL4T4HPUKL-P1 3C#12 PWR 600V STATION HPU SERVICE PANEL B.L.#4 109-45-107 HPU UNIT 4 KIDNEY LOOP PUMP DISCONNECT SW. 109-45-107BL4T4HPUHTR-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#4109-45-107HPU UNIT 4 TANK HEATER DISCONNECT SW.109-45-107BL4-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#4430550-F22TURBINE GENERATOR G4 SPACE HEATER LEADS430550-F222" CONDUIT(GILKES ITEM 8)BL5T5HPU1-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#5109-45-107HPU UNIT 5 PUMP No.1 DISCONNECT SWITCH109-45-107BL5T5HPU2-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#5109-45-107HPU UNIT 5 PUMP No.2 DISCONNECT SWITCH109-45-107BL5T5HPUKL-P1 3C#12 PWR 600V STATION HPU SERVICE PANEL B.L.#5 109-45-107 HPU UNIT 5 KIDNEY LOOP PUMP DISCONNECT SW. 109-45-107BL5T5HPUHTR-P1 3C#12 PWR 600VSTATION HPU SERVICE PANEL B.L.#5109-45-107HPU UNIT 5 TANK HEATER DISCONNECT SW.109-45-107BL5-P13C#12PWR600VSTATION HPU SERVICE PANEL B.L.#5430550-F22TURBINE GENERATOR G5 SPACE HEATER LEADS430550-F222" CONDUIT(GILKES ITEM 8)BL5-P13C#12PWR600VSTATION HPU SERVICE PANEL B.L.#5430550-F22TURBINE GENERATOR G5 SPACE HEATER LEADS430550-F222" CONDUIT(GILKES ITEM 8)SSP1SSP2-P1 1-4C#250MCM PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109480V STATION SERVICE PANELBOARD SSP2109-45-1104" CONDUITSSP1BST1-P1 3C#4 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109BUILDING SERVICE TRANSFOMER BST1 109-45-1091.5" CONDUITSSP1P1A/B-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109SUMP PUMP DUPLEX CONTROL PANEL109-45-109480V CABLE TRAY & .75" CONDUITSSP1P1A-P1 3C#12 PWR 600VSUMP PUMP DUPLEX CONTROL PANEL109-45-109SUMP PUMP P-1A109-45-1092" CONDUITSSP1P1B-P1 3C#12 PWR 600VSUMP PUMP DUPLEX CONTROL PANEL109-45-109SUMP PUMP P-1B109-45-1092" CONDUITSSP1P2A/B-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109SEWAGE LIFT PUMP DUPLEX CONTROL PANEL109-45-109480V CABLE TRAY & 2" CONDUITSSP1P2A-P1 3C#12 PWR 600VSEWAGE LIFT PUMP DUPLEX CONTROL PANEL109-45-109SEWAGE LIFT PUMP P-2A109-45-1092" CONDUITSSP1P2B-P1 3C#12 PWR 600VSEWAGE LIFT PUMP DUPLEX CONTROL PANEL109-45-109SEWAGE LIFT PUMP P-2B109-45-1092" CONDUITSSP1EF1-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109POWERHOUSE EXHAUST FAN EF-1109-45-109480V CABLE TRAY & .75" CONDUITSSP1AC1-P1 3C#10 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109AIR COMPRESSOR AC-1109-45-109480V CABLE TRAY & .75" CONDUITSSP1AC2-P1 3C#10 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109AIR COMPRESSOR AC-2109-45-109480V CABLE TRAY & .75" CONDUITSSP1PHCF-P1 3C#4 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109POWERHOUSE CRANE109-45-109480V CABLE TRAY & 1.5" CONDUITSSP19-P1 2C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109POWERHOUSE HIGH BAY LIGHTING109-45-109480V CABLE TRAY & .5" CONDUITSSP110-P1 2C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109POWERHOUSE HIGH BAY LIGHTING109-45-109480V CABLE TRAY & .5" CONDUITSSP111-P1 2C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109POWERHOUSE HIGH BAY LIGHTING109-45-109480V CABLE TRAY & .5" CONDUITSSP112-P1 2C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109POWERHOUSE HIGH BAY LIGHTING109-45-109480V CABLE TRAY & .5" CONDUITSSP116-P1 3C#2 PWR 600V480V STATION SERVICE PANELBOARD SSP1109-45-109SUBSTATION CONTROL BUILDING109-55-002480V CABLE TRAY & 4" CONDUITSSP2BST2-P1 3C#8 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110BUILDING SERVICE TRANSFOMER BST2109-45-1101" CONDUITSSP2PHWR1A-P1 3C#4 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE WELDING RECEPTACLE WR1A109-45-110480V CABLE TRAY & 1.5" CONDUITWR1AWR1B-P1 3C#4 PWR 600VPOWERHOUSE WELDING RECEPTACLE WR1A109-45-110POWERHOUSE WELDING RECEPTACLE WR1B109-45-110480V CABLE TRAY & 1.5" CONDUITWR1BWR1C-P1 3C#4 PWR 600VPOWERHOUSE WELDING RECEPTACLE WR1B109-45-110POWERHOUSE WELDING RECEPTACLE WR1C109-45-110480V CABLE TRAY & 1.5" CONDUITSSP2PHWR2A-P1 3C#4 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE WELDING RECEPTACLE WR2A109-45-110480V CABLE TRAY & 1.5" CONDUITWR1AWR2B-P13C#4PWR600VPOWERHOUSE WELDING RECEPTACLE WR2A109-45-110POWERHOUSE WELDING RECEPTACLE WR2B109-45-110480V CABLE TRAY & 1.5" CONDUITWR1AWR2B-P13C#4PWR600VPOWERHOUSE WELDING RECEPTACLE WR2A109-45-110POWERHOUSE WELDING RECEPTACLE WR2B109-45-110480V CABLE TRAY & 1.5" CONDUITSSP2UH2-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-2109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH3-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-3109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH4-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-4109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH5-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-5109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH6-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-6109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH7-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-7109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH8-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-8109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH9-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-9109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH10-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-10109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH11-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-11109-45-110480V CABLE TRAY & .75" CONDUITSSP2UH12-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE UNIT HEATER UH-12109-45-110480V CABLE TRAY & .75" CONDUITSSP2WH2-P1 3C#10 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE WATER HEATER WH-2109-45-110480V CABLE TRAY & .75" CONDUITSSP2AHU1-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE AIR HANDLING UNIT AHU-1109-45-110480V CABLE TRAY & .75" CONDUIT109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No. DESCRIPTION DWG. No. ROUTEBLUE LAKE EXPANSION PROJECT - Cable Schedule - 600V power cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGEFROMTOREMARKS REVSSP2AHU2-P1 3C#10 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE AIR HANDLING UNIT AHU-2109-45-110480V CABLE TRAY & .75" CONDUITSSP2AHU3-P1 3C#12 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE AIR HANDLING UNIT AHU-3109-45-110480V CABLE TRAY & .75" CONDUITSSP2AHU4-P1 3C#10 PWR 600V480V STATION SERVICE PANELBOARD SSP2109-45-110POWERHOUSE AIR HANDLING UNIT AHU-4109-45-110480V CABLE TRAY & .75" CONDUITBST1DP1-P1 4C#2/0 PWR 600VBUILDING SERVICE TRANSFOMER BST1109-45-109BUILDING SERVICE PANELBOARD DP1109-45-1092.5" CONDUITBST1LPA-P1 4C#2/0 PWR 600VBUILDING SERVICE TRANSFOMER BST2109-45-110BUILDING SERVICE PANELBOARD LPA109-45-1101.5" CONDUIT109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No. DESCRIPTION DWG. No. ROUTEBLUE LAKE EXPANSION PROJECT - Cable Schedule - 600V power cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGEFROMTOREMARKS REVRAW WATER PUMPSRWPT3RWP-P1 1-4C#350MCM PWR 600VRAW WATER PUMPS TRANSFORMER RWPT3109-45-111480V MCC RWP, BKR CB-RWP1109-45-111480V CABLE TRAY & 4" CONDUITRWPT3RWP-P2 1-4C#350MCM PWR 600VRAW WATER PUMPS TRANSFORMER RWPT3109-45-111480V MCC RWP, BKR CB-RWP1109-45-111480V CABLE TRAY & 4" CONDUITNSRAAP3A-P1 3C#2 PWR 600V480VMCC RWP, BKR CB-RWP2109-45-111NSRAA PUMP P-3A109-45-111480V CABLE TRAY & 2" CONDUITNSRAAP3B-P1 3C#2 PWR 600V480V MCC RWP, BKR CB-RWP3109-45-111NSRAA PUMP P-3B109-45-111480V CABLE TRAY & 2" CONDUITPWPP4A-P1 1-3C#250MCM PWR 600V480V SWITCHGEAR RWP, BKR CB-RWP4109-45-111POTABLE WATER PUMP P-4A109-45-111480V CABLE TRAY & 4" CONDUITPWPP4B-P1 1-3C#250MCM PWR 600V480V SWITCHGEAR RWP, BKR CB-RWP5109-45-111POTABLE WATER PUMP P-4B109-45-111480V CABLE TRAY & 4" CONDUITCBRWP6WTP-P1 3C#4/0 PWR 600V480V SWITCHGEAR RWP, BKR CB-RWP6109-45-111WATER TREATMENT PLANT109-45-111480V CABLE TRAY & 4" CONDUITGATE HOUSET5GHSSP1-P1 4C#2 PWR 600V TRANSFORMER T5109-26-100GATE HOUSE SERVICE PANELBOARD GHSSP1109-26-1004" CONDUITGHSSP1FWGH-P1 3C#12 PWR 600V480V SERVICE PANELBOARD GHSSP1109-26-100FIXED WHEEL GATE HOIST 'FWGH'109-26-100.75" CONDUITGHSSP1HU1-P1 3C#10 PWR 600V480V SERVICE PANELBOARD GHSSP1109-26-100UNIT HEATER HU-1109-26-100.75" CONDUITGHSSP1HU2-P1 3C#10 PWR 600V480V SERVICE PANELBOARD GHSSP1109-26-100UNIT HEATER HU-2109-26-100.75" CONDUITGHSSP1AC1-P13C#10PWR600V480V SERVICE PANELBOARD GHSSP1109-26-100AIR COMPRESSOR AC-1109-26-100.75" CONDUITGHSSP1AC1-P13C#10PWR600V480V SERVICE PANELBOARD GHSSP1109-26-100AIR COMPRESSOR AC-1109-26-100.75" CONDUITGHSSP1GHT1-P1 3C#8 PWR 600V480V SERVICE PANELBOARD GHSSP1109-26-100BUILDING SERVICE TRANSFOMER GHT1109-26-1001" CONDUITGHT1LPA-P1 4C#6 PWR 600VBUILDING SERVICE TRANSFOMER GHT1109-26-100GATE HOUSE LIGHTING PANELBOARD LPA109-26-1001.5" CONDUITDAMLPA-P1 4C#2 PWR 600VLIGHTING PANELBOARD LPA109-26-100DAM LIGHTING PANELBOARD LPA109-26-1002" CONDUIT109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No.DESCRIPTIONDWG. No. ROUTE T1-P1 1-2C#10 PWR 600V DISTRIBUTION PANELBOARD DP1109-45-109 TRANSFORMER T1 CONTROL PANEL4" CONDUIT & PWR/CNTL TRAYT1-C1 1-4C#10 CNTL 600V SWITCHYARD CONTROL PANEL T1 (SEL-787) 109-45-101 TRANSFORMER T1 CONTROL PANEL (PRIMARY CT'S)4" CONDUITT1-C2 1-4C#10 CNTL 600V SWITCHYARD CONTROL PANEL T1 (SEL-787) 109-45-101 TRANSFORMER T1 CONTROL PANEL (SECONDARY CT'S)4" CONDUITT1-C3 1-2C#10 CNTL 600V SWITCHYARD CONTROL PANEL T1 (SEL-787) 109-45-101 TRANSFORMER T1 CONTROL PANEL (NEUTRAL CT)4" CONDUITT1-C4 3-TRI#16 RTD'S 300V SWITCHYARD CONTROL PANEL T1 (SEL-787) 109-45-101 TRANSFORMER T1 CONTROL PANEL (RTD'S)4" CONDUITT1-C5 1-7C#12 CNTL 600V SWITCHYARD CONTROL PANEL T1 (SEL-787) 109-45-101 TRANSFORMER T1 CONTROL PANEL (63L & 63SP)4" CONDUITT1-C6 1-7C#12 CNTL 600V SWITCHYARD CONTROL PANEL T1 (SEL-787) 109-45-101 SWGR '1' BKR '52-T1' (TRIP & ALARMS)4" CONDUIT & PWR/CNTL TRAYT2-P1 1-2C#10 PWR 600V DISTRIBUTION PANELBOARD DP1109-45-109 TRANSFORMER T2 CONTROL PANEL4" CONDUIT & PWR/CNTL TRAYT2-C11-4C#10CNTL600VSWITCHYARD CONTROL PANEL T2 (SEL-787)109-45-101TRANSFORMER T2 CONTROL PANEL (PRIMARY CT'S)4" CONDUITTOREMARKS REV12.47kV TRANSFORMER T112.47kV TRANSFORMER T2BLUE LAKE EXPANSION PROJECT - Cable Schedule - control cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGEFROMT2-C11-4C#10CNTL600VSWITCHYARD CONTROL PANEL T2 (SEL-787)109-45-101TRANSFORMER T2 CONTROL PANEL (PRIMARY CT'S)4" CONDUITT2-C2 1-4C#10 CNTL 600V SWITCHYARD CONTROL PANEL T2 (SEL-787) 109-45-101 TRANSFORMER T2 CONTROL PANEL (SECONDARY CT'S)4" CONDUITT2-C3 1-2C#10 CNTL 600V SWITCHYARD CONTROL PANEL T2 (SEL-787) 109-45-101 TRANSFORMER T2 CONTROL PANEL (NEUTRAL CT)4" CONDUITT2-C4 3-TRI#16 RTD'S 300V SWITCHYARD CONTROL PANEL T2 (SEL-787) 109-45-101 TRANSFORMER T2 CONTROL PANEL (RTD'S)4" CONDUITT2-C5 1-7C#12 CNTL 600V SWITCHYARD CONTROL PANEL T2 (SEL-787) 109-45-101 TRANSFORMER T2 CONTROL PANEL (63L & 63SP)4" CONDUITT2-C6 1-7C#12 CNTL 600V SWITCHYARD CONTROL PANEL T2 (SEL-787) 109-45-101 SWGR '2' BKR '52-T2' (TRIP & ALARMS)4" CONDUIT & PWR/CNTL TRAY52SST1-C1 1-5C#14 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-SST1 (SEL-751A) 109-45-101 MEZZANINE CONTROL PANELCNTL TRAY52RWPT3-C1 1-5C#14 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-RWPT3 (SEL-751A) 109-45-101 MEZZANINE CONTROL PANELCNTL TRAY521-C1 1-5C#14 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-1 (SEL-751A) 109-45-101 MEZZANINE CONTROL PANELCNTL TRAY52G4-P1 1-2C#12 PWR 600V 15kV SWITCHGEAR '1', BKR 52-G4 (PT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4) 109-45-102 CNTL TRAY52G4-C1 1-4C#10 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-G4 (LINE CT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4), (SEL-700G) 109-45-102 CNTL TRAY52G4-C2 1-2C#12 CNTL 600V 15kV SWITCHGEAR '1', BUS No.1 (PT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4) (SEL-700G & SEL-734) 109-45-102 CNTL TRAY52G4-C3 1-5C#14 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-G4 (TRIP) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4), (SEL-700G) 109-45-102 CNTL TRAY52G5-P1 1-2C#12 PWR 600V 15kV SWITCHGEAR '1', BKR 52-G5 (PT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5) 109-45-102 CNTL TRAY52G5-C1 1-4C#10 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-G5 (LINE CT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5), (SEL-700G) 109-45-102 CNTL TRAY52G5-C2 1-2C#12 CNTL 600V 15kV SWITCHGEAR '1', BUS No.1 (PT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5) (SEL-700G & SEL-734) 109-45-102 CNTL TRAY52G5-C3 1-5C#14 CNTL 600V 15kV SWITCHGEAR '1', BKR 52-G5 (TRIP) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5), (SEL-700G) 109-45-102 CNTL TRAY52SST2-C1 1-5C#14 CNTL 600V 15kV SWITCHGEAR '2', BKR 52-SST2 (SEL-751A) 109-45-101 MEZZANINE CONTROL PANELCNTL TRAY12.47kV SWITCHGEAR 1/252T4-C1 1-5C#14 CNTL 600V 15kV SWITCHGEAR '2', BKR 52-T4 (SEL-751A) 109-45-101 MEZZANINE CONTROL PANELCNTL TRAY522-C1 1-5C#14 CNTL 600V 15kV SWITCHGEAR '2', BKR 52-2 (SEL-751A) 109-45-101 MEZZANINE CONTROL PANELCNTL TRAY52G3-P1 1-2C#12 PWR 600V 15kV SWITCHGEAR '2', BKR 52-G3 (PT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3) 109-45-102 CNTL TRAY52G3-C1 1-4C#10 CNTL 600V 15kV SWITCHGEAR '2', BKR 52-G3 (LINE CT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3), (SEL-700G) 109-45-102 CNTL TRAY52G3-C2 1-2C#12 CNTL 600V 15kV SWITCHGEAR '2', BUS No.2 (PT'S) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3) (SEL-700G & SEL-734) 109-45-102 CNTL TRAY52G3-C3 1-5C#14 CNTL 600V 15kV SWITCHGEAR '2', BKR 52-G3 (TRIP) 109-45-101 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3), (SEL-700G) 109-45-102 CNTL TRAYPLC-C1 1-12C#14 CNTL 600V SWITCHGEAR 1/2 PLC CONTROL CABINET 109-45-101 JUNCTION BOX IN EXIST PWR PLANT 480V TERMINATION POINT 109-55-002 CNTL TRAY & CONDUIT (LOAD SHED CONTROL CABLE)109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No.DESCRIPTIONDWG. No. ROUTETOREMARKS REVBLUE LAKE EXPANSION PROJECT - Cable Schedule - control cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGEFROMG3-C1 1-4C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 3 (G3), CT's MCT1, 2 & 3 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (SEL-734, RM)2" CONDUITG3-C2 1-4C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 3 (G3), CT's DCT1, 2 & 3 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (DSLC SYNC)2" CONDUITG3-C3 1-2C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 3 (G3), CT GFCT 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (SEL-700G)2" CONDUITG3-C4 1-2C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 3 (G3), CT CCCT 14DSB-2558TURBINE/GENERATOR CONTROL PANEL UNIT 3 (EXCITER CROSS CURRENT COMPENSATION)2" CONDUITG3-C5 1-2C#12 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 3 (G3), SPACE HEATER 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUITG3-C6 1-2C#12 CNTL 600V GENERATOR LINE CUBICAL UNIT 3 (G3), SPACE HEATER 14DSB-2557 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUITG3-C7 4-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 3, T1 / T4)G3-C8 4-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 3, T2 / T5)G3-C9 4-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 3, T3 / T6)G3-C10 2-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 4)G3-C11 2-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 5)G3-C124-TRI#16CNTL600VTURBINE GENERATOR (G3) MARSHALLING CUBICLE430550-F22TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT(GILKES ITEM 6 & 7)TURBINE GENERATOR G3G3-C124-TRI#16CNTL600VTURBINE GENERATOR (G3) MARSHALLING CUBICLE430550-F22TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT(GILKES ITEM 6 & 7)G3-C13 1-8C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 11)G3-C14 1-3C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 13)G3-C15 2-4C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 14)G3-C16 3-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) DE BEARING ACCESSORY BOX 430550-F22 1" CONDUIT (GILKES ITEM 6 & 7)G3-C17 1-4C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) DE BEARING ACCESSORY BOX 430550-F22 1" CONDUIT (GILKES ITEM 11)G3-C18 1-TRI#16 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 7)G3-C19 1-4C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 11)G3-C20 1-3C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 13)G3-C21 1-4C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 14)G3-C22 1-4C#14 CNTL 600V TURBINE GENERATOR (G3) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G3) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 14)G3-C23 1-2C#14 PWR 600V TURBINE GENERATOR (G3) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 12) (+24V PWR)G3-C24 1-7C#14 PWR 600V TURBINE GENERATOR (G3) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT(GILKES ITEM 12) (CONTROLS & ALARM)G3-C25 2-PR#16 PWR 600V TURBINE GENERATOR (G3) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 12) (INPUT/ANALOG)G3-C26 1-2C#14 PWR 600V TURBINE GENERATOR (G3) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 12) (+24V PWR)G3-C27 1-7C#14 PWR 600V TURBINE GENERATOR (G3) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT(GILKES ITEM 12) (CONTROLS & ALARM)G3-C28 2-PR#16 PWR 600V TURBINE GENERATOR (G3) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 12) (INPUT/ANALOG)G3-P1 1-2C#12 PWR 600V TURBINE GENERATOR (G3) EXCITATION SYSTEM (S) 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 3 (G3)2" CONDUIT (GILKES ITEM 9) (VR)G3-P21-2C#12PWR600VTURBINE/GENERATOR (G3) CONTROL PANEL UNIT 3 (VR)430550-F22TURBINE GENERATOR (G3) EXCITATION SYSTEM2" CONDUIT(GILKES ITEM 10) (PMG)G3-P21-2C#12PWR600VTURBINE/GENERATOR (G3) CONTROL PANEL UNIT 3 (VR)430550-F22TURBINE GENERATOR (G3) EXCITATION SYSTEM2" CONDUIT(GILKES ITEM 10) (PMG)G4-C1 1-4C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 4 (G4), CT's MCT1, 2 & 3 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (SEL-734, RM)2" CONDUITG4-C2 1-4C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 4 (G4), CT's DCT1, 2 & 3 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (DSLC SYNC)2" CONDUITG4-C3 1-2C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 4 (G4), CT GFCT 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (SEL-700G)2" CONDUITG4-C4 1-2C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 4 (G4), CT CCCT 14DSB-2558TURBINE/GENERATOR CONTROL PANEL UNIT 4 (EXCITER CROSS CURRENT COMPENSATION)2" CONDUITG4-C5 1-2C#12 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 4 (G4), SPACE HEATER 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUITG4-C6 1-2C#12 CNTL 600V GENERATOR LINE CUBICAL UNIT 4 (G4), SPACE HEATER 14DSB-2557 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUITG4-C7 4-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 3, T1 / T4)G4-C8 4-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 3, T2 / T5)G4-C9 4-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 3, T3 / T6)G4-C10 2-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 4)G4-C11 2-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 5)G4-C12 4-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 6 & 7)G4-C13 1-8C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 11)G4-C14 1-3C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 13)G4-C15 2-4C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 14)G4-C16 3-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) DE BEARING ACCESSORY BOX 430550-F22 1" CONDUIT (GILKES ITEM 6 & 7)G4-C17 1-4C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) DE BEARING ACCESSORY BOX 430550-F22 1" CONDUIT (GILKES ITEM 11)TURBINE GENERATOR G4G4-C18 1-TRI#16 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 7)G4-C19 1-4C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 11)G4-C20 1-3C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 13)G4-C21 1-4C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 14)G4-C22 1-4C#14 CNTL 600V TURBINE GENERATOR (G4) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G4) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 14)G4-C23 1-2C#14 PWR 600V TURBINE GENERATOR (G4) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 12) (+24V PWR)G4-C24 1-7C#14 PWR 600V TURBINE GENERATOR (G4) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT(GILKES ITEM 12) (CONTROLS & ALARM)G4-C25 2-PR#16 PWR 600V TURBINE GENERATOR (G4) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 12) (INPUT/ANALOG)G4-C26 1-2C#14 PWR 600V TURBINE GENERATOR (G4) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 12) (+24V PWR)G4-C27 1-7C#14 PWR 600V TURBINE GENERATOR (G4) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT(GILKES ITEM 12) (CONTROLS & ALARM)G4-C28 2-PR#16 PWR 600V TURBINE GENERATOR (G4) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 12) (INPUT/ANALOG)G4-P1 1-2C#12 PWR 600V TURBINE GENERATOR (G4) EXCITATION SYSTEM (S) 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 4 (G4)2" CONDUIT (GILKES ITEM 9) (VR)G4-P2 1-2C#12 PWR 600V TURBINE/GENERATOR (G4) CONTROL PANEL UNIT 4 (VR) 430550-F22 TURBINE GENERATOR (G4) EXCITATION SYSTEM2" CONDUIT (GILKES ITEM 10) (PMG)109-45-180_Cable Schedule.xls4/16/2012 Project No. H-332360Drawing No. 109-45-180 Rev. ABlue Lake Expansion ProjectCity and Borough of Sitka AlaskaDESCRIPTION DWG. No.DESCRIPTIONDWG. No. ROUTETOREMARKS REVBLUE LAKE EXPANSION PROJECT - Cable Schedule - control cablesDrawing No. 109-45-180 Rev.P2CABLENUMBERROUTINGSIZE TYPE VOLTAGEFROMG5-C1 1-4C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 5 (G5), CT's MCT1, 2 & 3 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (SEL-734, RM)2" CONDUITG5-C2 1-4C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 5 (G5), CT's DCT1, 2 & 3 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (DSLC SYNC)2" CONDUITG5-C3 1-2C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 5 (G5), CT GFCT 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (SEL-700G)2" CONDUITG5-C4 1-2C#10 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 5 (G5), CT CCCT 14DSB-2558TURBINE/GENERATOR CONTROL PANEL UNIT 5 (EXCITER CROSS CURRENT COMPENSATION)2" CONDUITG5-C5 1-2C#12 CNTL 600V GENERATOR NEUTRAL CUBICLE UNIT 5 (G5), SPACE HEATER 14DSB-2558 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUITG5-C6 1-2C#12 CNTL 600V GENERATOR LINE CUBICAL UNIT 5 (G5), SPACE HEATER 14DSB-2557 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUITG5-C7 4-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 3, T1 / T4)G5-C8 4-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 3, T2 / T5)G5-C9 4-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 3, T3 / T6)G5-C10 2-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 4)G5-C11 2-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 5)G5-C124-TRI#16CNTL600VTURBINE GENERATOR (G5) MARSHALLING CUBICLE430550-F22TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT(GILKES ITEM 6 & 7)TURBINE GENERATOR G5G5-C124-TRI#16CNTL600VTURBINE GENERATOR (G5) MARSHALLING CUBICLE430550-F22TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT(GILKES ITEM 6 & 7)G5-C13 1-8C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 11)G5-C14 1-3C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 13)G5-C15 2-4C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 14)G5-C16 3-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) DE BEARING ACCESSORY BOX 430550-F22 1" CONDUIT (GILKES ITEM 6 & 7)G5-C17 1-4C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) DE BEARING ACCESSORY BOX 430550-F22 1" CONDUIT (GILKES ITEM 11)G5-C18 1-TRI#16 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 7)G5-C19 1-4C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 11)G5-C20 1-3C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 13)G5-C21 1-4C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 14)G5-C22 1-4C#14 CNTL 600V TURBINE GENERATOR (G5) MARSHALLING CUBICLE 430550-F22 TURBINE/GENERATOR (G5) ODE BEARING ACCESSORY BOX 430550-F22 2" CONDUIT (GILKES ITEM 14)G5-C23 1-2C#14 PWR 600V TURBINE GENERATOR (G5) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 12) (+24V PWR)G5-C24 1-7C#14 PWR 600V TURBINE GENERATOR (G5) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT(GILKES ITEM 12) (CONTROLS & ALARM)G5-C25 2-PR#16 PWR 600V TURBINE GENERATOR (G5) DE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 12) (INPUT/ANALOG)G5-C26 1-2C#14 PWR 600V TURBINE GENERATOR (G5) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 12) (+24V PWR)G5-C27 1-7C#14 PWR 600V TURBINE GENERATOR (G5) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT(GILKES ITEM 12) (CONTROLS & ALARM)G5-C28 2-PR#16 PWR 600V TURBINE GENERATOR (G5) ODE BEARING VIBRATION SWITCH 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 12) (INPUT/ANALOG)G5-P1 1-2C#12 PWR 600V TURBINE GENERATOR (G5) EXCITATION SYSTEM (S) 430550-F22 TURBINE/GENERATOR CONTROL PANEL UNIT 5 (G5)2" CONDUIT (GILKES ITEM 9) (VR)G5-P21-2C#12PWR600VTURBINE/GENERATOR (G5) CONTROL PANEL UNIT 5 (VR)430550-F22TURBINE GENERATOR (G5) EXCITATION SYSTEM2" CONDUIT(GILKES ITEM 10) (PMG)G5-P21-2C#12PWR600VTURBINE/GENERATOR (G5) CONTROL PANEL UNIT 5 (VR)430550-F22TURBINE GENERATOR (G5) EXCITATION SYSTEM2" CONDUIT(GILKES ITEM 10) (PMG) CBSST1-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB1 BKR CB-SST1 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYCBSSB11-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB1 BKR CB-SSB11 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYCBSSB12-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB1 BKR CB-SSB12 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAY SPARE BKRCBSSB13-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB1 BKR CB-SSB13 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYCBSSB14-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB1 BKR CB-SSB14 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAY CBSST2-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB2 BKR CB-SST2 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYCBSSB21-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB2 BKR CB-SSB21 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYCBSSB23-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB2 BKR CB-SSB23 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYCBSSB24-C1 1-5C#14 CNTL 600V STATION SERVICE BUS SSB2 BKR CB-SSB24 (BKR STATUS) 109-45-107 MEZZANINE CONTROL PANELCNTL TRAYNSRAALCP-C1 1-12C#14 CNTL 600V 480V RAW WATER PUMP MCC RWP109-45-111 LOCAL CONTROL PANEL 1A109-45-111 CNTL TRAY & 2" CONDUITRWPP4A-C1 1-7C#14 CNTL 600V 480V RAW WATER PUMP MCC RWP109-45-111 PUMP P-4A LOCAL PB PANEL109-45-111 CNTL TRAY & 2" CONDUITRWPP4B-C1 1-7C#14 CNTL 600V 480V RAW WATER PUMP MCC RWP109-45-111 PUMP P-4B LOCAL PB PANEL109-45-111 CNTL TRAY & 2" CONDUIT480V STATION SERVICE BUS SSB1 & SSB2480V MCC RWP109-45-180_Cable Schedule.xls4/16/2012