Loading...
HomeMy WebLinkAboutWrangell Downtown Application Renewable Energy Fund Round 3 Grant Application AEA 10-015 Application Page 1 of 11 10/7/2009 Application Forms and Instructions The following forms and instructions are provided to assist you in preparing your application for a Renewable Energy Fund Grant. An electronic version of the Request for Applications (RFA) and the forms are available online at: http://www.akenergyauthority.org/RE_Fund-III.html Grant Application Form GrantApp3.doc Application form in MS Word that includes an outline of information required to submit a complete application. Applicants should use the form to assure all information is provided and attach additional information as required. Application Cost Worksheet Costworksheet3 .doc Summary of Cost information that should be addressed by applicants in preparing their application. Grant Budget Form GrantBudget3.d oc A detailed grant budget that includes a breakdown of costs by milestone and a summary of funds available and requested to complete the work for which funds are being requested. Grant Budget Form Instructions GrantBudgetInst ructions3.pdf Instructions for completing the above grant budget form. • If you are applying for grants for more than one project, provide separate application forms for each project. • Multiple phases for the same project may be submitted as one application. • If you are applying for grant funding for more than one phase of a project, provide milestones and grant budget for completion of each phase. • If some work has already been completed on your project and you are requesting funding for an advanced phase, submit information sufficient to demonstrate that the preceding phases are satisfied and funding for an advanced phase is warranted. • If you have additional information or reports you would like the Authority to consider in reviewing your application, either provide an electronic version of the document with your submission or reference a web link where it can be downloaded or reviewed. REMINDER: • Alaska Energy Authority is subject to the Public Records Act AS 40.25, and materials submitted to the Authority may be subject to disclosure requirements under the act if no statutory exemptions apply. • All applications received will be posted on the Authority web site after final recommendations are made to the legislature. • In accordance with 3 AAC 107.630 (b) Applicants may request trade secrets or proprietary company data be kept confidential subject to review and approval by the Authority. If you want information is to be kept confidential the applicant must: o Request the information be kept confidential. o Clearly identify the information that is the trade secret or proprietary in their application. o Receive concurrence from the Authority that the information will be kept confidential. If the Authority determines it is not confidential it will be treated as a public record in accordance with AS 40.25 or returned to the applicant upon request. Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 2 of 11 10/7/2009 SECTION 1 – APPLICANT INFORMATION Name (Name of utility, IPP, or government entity submitting proposal) City and Borough of Wrangell Type of Entity: Local Municipal Government Mailing Address City & Borough of Wrangell P.O. Box 531 Wrangell, Alaska 99929 Physical Address City and Borough of Wrangell 205 Brueger Street Wrangell, Alaska 99929 Telephone (907) 874-2381 Fax (907) 874-8952 Email tdrooney@wrangell.com 1.1 APPLICANT POINT OF CONTACT Name Steven Henson Title Electrical Superintendent Mailing Address Wrangell Municipal Light & Power P.O. Box 531 Wrangell, Alaska 99929 Telephone (907) 874-3602 Fax (907) 874-3614 Email linedept@gci.net 1.2 APPLICANT MINIMUM REQUIREMENTS Please check as appropriate. If you do not to meet the minimum applicant requirements, your application will be rejected. 1.2.1 As an Applicant, we are: (put an X in the appropriate box) An electric utility holding a certificate of public convenience and necessity under AS 42.05, or An independent power producer in accordance with 3 AAC 107.695 (a) (1), or X A local government, or A governmental entity (which includes tribal councils and housing authorities); Yes 1.2.2. Attached to this application is formal approval and endorsement for its project by its board of directors, executive management, or other governing authority. If the applicant is a collaborative grouping, a formal approval from each participant’s governing authority is necessary. (Indicate Yes or No in the box ) Yes 1.2.3. As an applicant, we have administrative and financial management systems and follow procurement standards that comply with the standards set forth in the grant agreement. Yes 1.2.4. If awarded the grant, we can comply with all terms and conditions of the attached grant form. (Any exceptions should be clearly noted and submitted with the application.) Yes 1.2.5 We intend to own and operate any project that may be constructed with grant funds for the benefit of the general public. Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 3 of 11 10/7/2009 SECTION 2 – PROJECT SUMMARY This is intended to be no more than a 1-2 page overview of your project. 2.1 Project Title – (Provide a 4 to 5 word title for your project) Wrangell Downtown Revitalization 2.2 Project Location – Include the physical location of your project and name(s) of the community or communities that will benefit from your project. Front Street from Stikine Avenue to Campbell Drive (north), Campbell Drive (south) to Episcopal Street, and Episcopal Street to Case Avenue in downtown Wrangell 2.3 PROJECT TYPE Put X in boxes as appropriate 2.3.1 Renewable Resource Type Wind Biomass or Biofuels X Hydro, including run of river X Transmission of Renewable Energy Geothermal, including Heat Pumps Small Natural Gas Heat Recovery from existing sources Hydrokinetic Solar Storage of Renewable Other (Describe) 2.3.2 Proposed Grant Funded Phase(s) for this Request (Check all that apply) Reconnaissance X Design and Permitting Feasibility X Construction and Commissioning Conceptual Design 2.4 PROJECT DESCRIPTION Provide a brief one paragraph description of your proposed project. The City and Borough of Wrangell would like to install new underground distribution systems on Front Street, replacing the existing overhead distribution systems. This project can be incorporated with the current Downtown Revitalization Plan which has already secured funding to upgrade the water, sewer, roadway and sidewalks along Front Street. 2.5 PROJECT BENEFIT Briefly discuss the financial and public benefits that will result from this project, (such as reduced fuel costs, lower energy costs, etc.)  Underground power distribution is aesthetically pleasing and more cost efficient to maintain. The current power lines and distribution transformers are dated and will require repair and/or replacement within the near future. This project offers a great opportunity to address these issues now as the Downtown Revitalization Plan already involves construction along Front Street. Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 4 of 11 10/7/2009 2.6 PROJECT BUDGET OVERVIEW Briefly discuss the amount of funds needed, the anticipated sources of funds, and the nature and source of other contributions to the project. The total estimate for this project is $1,506,857 Grant funding requested is $1,251,113 for design, material purchasing and construction costs Wrangell Municipal Light & Power will do in-kind work consisting of removing the existing overhead and inspection costs estimated at $255,744 2.7 COST AND BENEFIT SUMARY Include a summary of grant request and your project’s total costs and benefits below. Grant Costs (Summary of funds requested) 2.7.1 Grant Funds Requested in this application. $1,231,113 2.7.2 Other Funds to be provided (Project match) $255,744 2.7.3 Total Grant Costs (sum of 2.7.1 and 2.7.2) $1,506,857 Project Costs & Benefits (Summary of total project costs including work to date and future cost estimates to get to a fully operational project) 2.7.4 Total Project Cost (Summary from Cost Worksheet including estimates through construction) $1,506,857 2.7.5 Estimated Direct Financial Benefit (Savings) $ 2.7.6 Other Public Benefit (If you can calculate the benefit in terms of dollars please provide that number here and explain how you calculated that number in your application (Section 5.) $ SECTION 3 – PROJECT MANAGEMENT PLAN Describe who will be responsible for managing the project and provide a plan for successfully completing the project within the scope, schedule and budget proposed in the application. 3.1 Project Manager Tell us who will be managing the project for the Grantee and include a resume and references for the manager(s). If the applicant does not have a project manager indicate how you intend to solicit project management support. If the applicant expects project management assistance from AEA or another government entity, state that in this section. Greg Lockwood, Downtown Revitalization Project Manager State of Alaska Department of Transportation Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 5 of 11 10/7/2009 3.2 Project Schedule Include a schedule for the proposed work that will be funded by this grant. (You may include a chart or table attachment with a summary of dates below.) The proposed schedule for this phase is as follows Description Schedule Phase 1 – Design 1st quarter 2010 Phase 2 – Material Purchasing 2nd quarter 2010 Phase 3 – Construction Construction seasons 2010 & 2011 This project will coincide with the existing project and is estimated to be completed by the end of the 2011 construction season. 3.3 Project Milestones Define key tasks and decision points in your project and a schedule for achieving them. The Milestones must also be included on your budget worksheet to demonstrate how you propose to manage the project cash flow. (See Section 2 of the RFA or the Budget Form.) Key project milestones for this project include the following: Time frame Project Milestone 1st Quarter 2010 Engineering Design 2nd Quarter 2010 Material Acquisition Construction season 2010-2011 Construction/Decommission The project will start when the grant is awarded and be completed by the end of construction season 2011 If Wrangell experiences mild winters where construction would be allowed to continue this could be completed sooner 3.4 Project Resources Describe the personnel, contractors, equipment, and services you will use to accomplish the project. Include any partnerships or commitments with other entities you have or anticipate will be needed to complete your project. Describe any existing contracts and the selection process you may use for major equipment purchases or contracts. Include brief resumes and references for known, key personnel, contractors, and suppliers as an attachment to your application. Morris Engineering Group, LLC has the contract for electrical design for the Wrangell Downtown Revitalization Project. Morris Engineering Group had provided a preliminary cost estimate for this project. They would also be responsible for obtaining a contractor for the construction phase of the project Wrangell Municipal Light & Power would be responsible for purchasing materials and decommissioning the overhead power distribution system. Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 6 of 11 10/7/2009 3.5 Project Communications Discuss how you plan to monitor the project and keep the Authority informed of the status. Throughout the life of the project, the Project Manager will provide written and monthly updates to AEA which will include at a minimum: - Expenditures to date; - Percent complete; and - Narrative on progress including any scheduled changes. In addition, communications on project status will also be provided verbally with the AEA Project Manager on an informal basis through emails and phone conversations. 3.6 Project Risk Discuss potential problems and how you would address them. The only potential problem would be delay in acquiring materials this would only set back the completion date SECTION 4 – PROJECT DESCRIPTION AND TASKS • Tell us what the project is and how you will meet the requirements outlined in Section 2 of the RFA. • The level of information will vary according to phase(s) of the project you propose to undertake with grant funds. • If you are applying for grant funding for more than one phase of a project provide a plan and grant budget form for completion of each phase. • If some work has already been completed on your project and you are requesting funding for an advanced phase, submit information sufficient to demonstrate that the preceding phases are satisfied and funding for an advanced phase is warranted. 4.1 Proposed Energy Resource Describe the potential extent/amount of the energy resource that is available. Discuss the pros and cons of your proposed energy resource vs. other alternatives that may be available for the market to be served by your project. Not applicable 4.2 Existing Energy System 4.2.1 Basic configuration of Existing Energy System Briefly discuss the basic configuration of the existing energy system. Include information about the number, size, age, efficiency, and type of generation. Not applicable Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 7 of 11 10/7/2009 4.2.2 Existing Energy Resources Used Briefly discuss your understanding of the existing energy resources. Include a brief discussion of any impact the project may have on existing energy infrastructure and resources. Currently Wrangell uses hydropower supplied from the Tyee Lake Hydroelectric Facility. This project will not have any impact on the existing infrastructure or resources. 4.2.3 Existing Energy Market Discuss existing energy use and its market. Discuss impacts your project may have on energy customers. The distribution system on Front Street between Stikine Avenue and Campbell Drive (north) currently supplies power to 3 commercial customers. The distribution system on Front Street between Campbell Drive (south) and Case Avenue currently supplies energy to 24 residential customers (6 houses and 18 apartments) and 17 commercial customers. This project would only affect them during construction and then only when connecting their services to the new distribution line. 4.3 Proposed System Include information necessary to describe the system you are intending to develop and address potential system design, land ownership, permits, and environmental issues. 4.3.1 System Design Provide the following information for the proposed renewable energy system: • A description of renewable energy technology specific to project location • Optimum installed capacity • Anticipated capacity factor • Anticipated annual generation • Anticipated barriers • Basic integration concept • Delivery methods Not applicable 4.3.2 Land Ownership Identify potential land ownership issues, including whether site owners have agreed to the project or how you intend to approach land ownership and access issues. Land used for this project is owned by the City and Borough of Wrangell. 4.3.3 Permits Provide the following information as it may relate to permitting and how you intend to address outstanding permit issues. • List of applicable permits • Anticipated permitting timeline • Identify and discussion of potential barriers No permits will be required for this project. Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 8 of 11 10/7/2009 4.3.4 Environmental Address whether the following environmental and land use issues apply, and if so how they will be addressed: • Threatened or Endangered species • Habitat issues • Wetlands and other protected areas • Archaeological and historical resources • Land development constraints • Telecommunications interference • Aviation considerations • Visual, aesthetics impacts • Identify and discuss other potential barriers Converting to underground power will have positive visual and aesthetic impacts vs. the current overhead wires on wooden utility poles. 4.4 Proposed New System Costs and Projected Revenues (Total Estimated Costs and Projected Revenues) The level of cost information provided will vary according to the phase of funding requested and any previous work the applicant may have done on the project. Applicants must reference the source of their cost data. For example: Applicants Records or Analysis, Industry Standards, Consultant or Manufacturer’s estimates. 4.4.1 Project Development Cost Provide detailed project cost information based on your current knowledge and understanding of the project. Cost information should include the following: • Total anticipated project cost, and cost for this phase • Requested grant funding • Applicant matching funds – loans, capital contributions, in-kind • Identification of other funding sources • Projected capital cost of proposed renewable energy system • Projected development cost of proposed renewable energy system Total cost for this project is estimated to be $1,506,857. Wrangell is requesting funding in the amount of $1,251,113 with matching in-kind funds of $255,744. 4.4.2 Project Operating and Maintenance Costs Include anticipated O&M costs for new facilities constructed and how these would be funded by the applicant. (Note: Operational costs are not eligible for grant funds however grantees are required to meet ongoing reporting requirements for the purpose of reporting impacts of projects on the communities they serve.) Not applicable Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 9 of 11 10/7/2009 4.4.3 Power Purchase/Sale The power purchase/sale information should include the following: • Identification of potential power buyer(s)/customer(s) • Potential power purchase/sales price - at a minimum indicate a price range • Proposed rate of return from grant-funded project Not applicable 4.4.4 Project Cost Worksheet Complete the cost worksheet form which provides summary information that will be considered in evaluating the project. See Attachment B SECTION 5– PROJECT BENEFIT Explain the economic and public benefits of your project. Include direct cost savings, and how the people of Alaska will benefit from the project. The benefits information should include the following: • Potential annual fuel displacement (gal and $) over the lifetime of the evaluated renewable energy project • Anticipated annual revenue (based on i.e. a Proposed Power Purchase Agreement price, RCA tariff, or cost based rate) • Potential additional annual incentives (i.e. tax credits) • Potential additional annual revenue streams (i.e. green tag sales or other renewable energy subsidies or programs that might be available) • Discuss the non-economic public benefits to Alaskans over the lifetime of the project Converting to underground power will have positive visual and aesthetic impacts vs. the current overhead wires on wooden utility poles. SECTION 6– SUSTAINABILITY Discuss your plan for operating the completed project so that it will be sustainable. Include at a minimum: • Proposed business structure(s) and concepts that may be considered. • How you propose to finance the maintenance and operations for the life of the project • Identification of operational issues that could arise. • A description of operational costs including on-going support for any back-up or existing systems that may be require to continue operation • Commitment to reporting the savings and benefits Not applicable Renewable Energy Fund Grant Application Round 3 AEA10-015 Grant Application Page 10 of 11 10/7/2009 SECTION 7 – READINESS & COMPLIANCE WITH OTHER GRANTS Discuss what you have done to prepare for this award and how quickly you intend to proceed with work once your grant is approved. Tell us what you may have already accomplished on the project to date and identify other grants that may have been previously awarded for this project and the degree you have been able to meet the requirements of previous grants. Morris Engineering Group has been contacted and completed a preliminary cost evaluation for this part of the project. Once the grant is approved they would do a final system design then bidding could begin for the material and construction phase. City and Borough of Wrangell has secured grants from the State of Alaska Department of Commerce Community and Economic Development, the State of Alaska Department of Department of Environmental Conservation and the United States Environmental Protection Agency for partial funding of the Downtown Revitalization Project and is complying with all the requirements for those grants. SECTION 8– LOCAL SUPORT Discuss what local support or possible opposition there may be regarding your project. Include letters of support from the community that would benefit from this project. See Attachment A SECTION 9 – GRANT BUDGET Tell us how much you want in grant funds Include any investments to date and funding sources, how much is being requested in grant funds, and additional investments you will make as an applicant. Include an estimate of budget costs by milestones using the form – GrantBudget3.doc Grant Funding Requested- $1,251,113 Matching In-Kind Funding- $255,744 Total for this project- $1,506,857 See Attachment C – Grant Budget Worksheet I ., ALASKA Renewable Energy Fund ENERGY AUTHORITY Grant Application Round 3 SECTION 9 -ADDITIONAL DOCUMENTATION AND CERTIFICATION SUBMIT THE FOLLOWING DOCUMENTS WITH YOUR APPLICATION: A. Resumes of Applicant's Project Manager, key staff, partners, consultants, and suppliers per application form Section 3.1 and 3.4. B. Cost Worksheet per application form Section 4.4.4. C. Grant Budget Form per application form Section 9. D. Letters demonstrating local support per application form Section 8. E. An electronic version of the entire application on CD per RFA Section 1.6. F. Governing Body Resolution or other formal action taken by the applicant's governing body or management per RFA Section 1.4 that: Commits the organization to provide the matching resources for project at the match amounts indicated in the application. Authorizes the individual who signs the application has the authority to commit the organization to the obligations under the grant. I Provides as point of contact to represent the applicant for purposes of this application. Certifies the applicant is in compliance with applicable federal, state, and local, laws including existing credit and federal tax obligations. F. CERTIFICATION The undersigned certifies that this application for a renewable energy grant is truthful and correct, and that the applicant is in compliance with, and will continue to comply with, all federal and state laws including existing credit and federal tax obligations. Print Name Tim Rooney ~V\C)4J)-i<o IU...~ U U Borough Manager Signature Title Date /1 -g -"" 09 AEA 10-015 Grant Application Page 11 of 11 10/7/2009 Attachment B    Renewable Energy Fund Round 3 Project Cost/Benefit Worksheet   RFA AEA10-015 Application Cost Worksheet Page 1 10-7-09 Please note that some fields might not be applicable for all technologies or all project phases. The level of information detail varies according to phase requirements. 1. Renewable Energy Source The Applicant should demonstrate that the renewable energy resource is available on a sustainable basis. Annual average resource availability. 100% Hydropower Unit depends on project type (e.g. windspeed, hydropower output, biomasss fuel) 2. Existing Energy Generation and Usage a) Basic configuration (if system is part of the Railbelt 1 grid, leave this section blank) i. Number of generators/boilers/other ii. Rated capacity of generators/boilers/other iii. Generator/boilers/other type iv. Age of generators/boilers/other v. Efficiency of generators/boilers/other b) Annual O&M cost (if system is part of the Railbelt grid, leave this section blank) i. Annual O&M cost for labor ii. Annual O&M cost for non-labor c) Annual electricity production and fuel usage (fill in as applicable) (if system is part of the Railbelt grid, leave this section blank) i. Electricity [kWh] ii. Fuel usage Diesel [gal] Other iii. Peak Load iv. Average Load v. Minimum Load vi. Efficiency vii. Future trends d) Annual heating fuel usage (fill in as applicable) i. Diesel [gal or MMBtu] ii. Electricity [kWh] iii. Propane [gal or MMBtu] iv. Coal [tons or MMBtu] v. Wood [cords, green tons, dry tons] vi. Other                                                              1 The Railbelt grid connects all customers of Chugach Electric Association, Homer Electric Association, Golden Valley Electric  Association, the City of Seward Electric Department, Matanuska Electric Association and Anchorage Municipal Light and Power.    Attachment B    Renewable Energy Fund Round 3 Project Cost/Benefit Worksheet   RFA AEA10-015 Application Cost Worksheet Page 2 10-7-09 3. Proposed System Design Capacity and Fuel Usage (Include any projections for continued use of non-renewable fuels) a) Proposed renewable capacity (Wind, Hydro, Biomass, other) [kWh or MMBtu/hr] b) Proposed Annual electricity or heat production (fill in as applicable) i. Electricity [kWh] ii. Heat [MMBtu] c) Proposed Annual fuel Usage (fill in as applicable) i. Propane [gal or MMBtu] ii. Coal [tons or MMBtu] iii. Wood [cords, green tons, dry tons] iv. Other 4. Project Cost a) Total capital cost of new system $1,506,857 b) Development cost c) Annual O&M cost of new system d) Annual fuel cost 5. Project Benefits a) Amount of fuel displaced for i. Electricity ii. Heat iii. Transportation b) Price of displaced fuel c) Other economic benefits d) Amount of Alaska public benefits 6. Power Purchase/Sales Price a) Price for power purchase/sale 7. Project Analysis a) Basic Economic Analysis Project benefit/cost ratio Payback Renewable Energy Fund Grant Round III Grant Budget Form 10-7-09 Milestone or Task Anticipated Completion Date RE- Fund Grant Funds Grantee Matching Funds Source of Matching Funds: Cash/In-kind/Federal Grants/Other State Grants/Other TOTALS Project scoping and contractor solicitation N/A $ $ $ Permit applications N/A $ $ $ Final environmental assessment N/A $ $ $ Resolution of land use N/A $ $ $ Permit approvals N/A $ $ $ Final system design 2010 $ $ $ Engineers cost estimate Completed $ $ $ Updated economical analysis N/A $ $ $ Negotiated power sales N/A $ $ $ Final business and operational plan 2010 $ $ TOTALS $ Budget Categories: Direct Labor & Benefits $ $ $ Travel & Per Diem $ $ $ Equipment $ $ $ Materials & Supplies $ $ $ Contractual Services $ $ $ Construction Services $ $ $ Other $ $ $ TOTALS $ $ $ Applications should include a separate worksheet for each project phase (Reconnaissance, Feasibility, Design and Permitting, and Construction)- Add additional pages as needed Renewable Energy Fund Grant Round III Grant Budget Form 10-7-09 Milestone or Task Anticipated Completion Date RE- Fund Grant Funds Grantee Matching Funds Source of Matching Funds: Cash/In-kind/Federal Grants/Other State Grants/Other TOTALS Confirmation all design requirements are complete 1st quarter 2010 $ $ $ Completion of bid documents 1st quarter 2010 $ $ $ Contractor/Vendor selection/award 2nd quarter 2010 $ $ $ Construction phases 2010-2011 $1,251,113 $ $1,251,113 Integration and testing 2011 $ $136,987 $136,987 Decommissioning old system 2011 $ $118,757 $118,757 Final acceptance 2011 $ $ $ Operations Report 2011 $ $ $ $ $ $ $ $ TOTALS $1,251,113 $255,744 $1,506,857 Budget Categories: Direct Labor & Benefits $ $87,361 $87,361 Travel & Per Diem $ $ $ Equipment $ $ $ Materials & Supplies $759,752 $31,396 $791,148 Contractual Services $ $ $ Construction Services $491,361 $136,987 $628,348 Other $ $ $ TOTALS $1,251,113 $255,744 $1,506,857 Applications should include a separate worksheet for each project phase (Reconnaissance, Feasibility, Design and Permitting, and Construction)- Add additional pages as needed MORRIS ENGINEERING GROUP, LLC PRELIMINARY CONSTRUCTION COST ESTIMATE PROJECT:Front Street STA 1+50 to 11+50 (Stikine Ave. to Cambell Dr.) JOB #:129-03 Date:11/04/09 Relocate all overhead to underground Labor multiplier 1.5 Labor rate 50 Materials multiplier 1.15 Material/Task Quantity Units Cost Material Labor Labor Subtotals Total Total 6" PVC 800 ft.2.0$ 1,840$ 0.05 3,000$ 4" PVC 1200 ft.1.0$ 1,380$ 0.04 3,600$ 2-1/2" PVC 1190 ft.0.6$ 821$ 0.03 2,678$ 2" PVC 400 ft.0.4$ 184$ 0.03 900$ Trenching/Backfilling 1190 ft.2.1$ 2,874$ 0.08 7,140$ Primary Junction Box 3 ea.7,000.0$ 24,150$ 24 5,400$ 1 Phase Transformer 3 ea.5,000.0$ 17,250$ 24 5,400$ 15KV, No. 350 1348.8 ft.7.50$ 11,633$ 0.07 7,081$ No. 350 XHHW 540 ft.5.55$ 3,447$ 0.05 2,025$ No. 4/0 XHHW 4284 ft.4.30$ 21,184$ 0.04 12,852$ 10 Pair Telephone Cable 624 ft.4$ 2,870$ 0.02 936$ Cable TV Cables 528 ft.4$ 2,429$ 0.02 792$ Secondary Service 7 ea.250$ 2,013$ 8.00 4,200$ Television Service 4 ea.150$ 690$ 8.00 2,400$ Telephone Service 4 ea.150$ 690$ 8.00 2,400$ Primary Cutovers 2 ea.7,500$ 17,250$ 48.00 7,200$ Television Cutovers 2 ea.1,500$ 3,450$ 24.00 3,600$ Telephone Cutovers 2 ea.1,500$ 3,450$ 24.00 3,600$ Demo Poles & Overhead 2 ea.1,500$ 3,450$ 64.00 9,600$ 117,605$ 75,204$ Total - 205,859$ Contingency (30%)35,281$ 22,561$ 61,758$ Profit (10%)11,760$ 7,520$ 20,586$ Total - Power Labor & Materials 164,647$ 105,285$ 288,202$ WML&P Overhead & Inspection 10%28,820$ Total Utility Work 317,022$ In-Kind 4,830$ 13,440$ 47,090$ Grant 269,932$ Page 1 MORRIS ENGINEERING GROUP, LLC s PRELIMINARY CONSTRUCTION COST ESTIMATE PROJECT:Front Street STA 11+50 to 19+50 (Cambell Dr. through Episcopal St.) JOB #:129-03 Date:11/04/09 Relocate all overhead to underground Labor multiplier 1.5 Labor rate 50 Materials multiplier 1.15 Material/Task Quantity Unit Cost Material Labor Labor Subtotals Total Total 6" PVC 2340 ft.2.0$ 5,382$ 0.05 8,775$ 4" PVC 3620 ft.1.0$ 4,163$ 0.04 10,860$ 2-1/2" PVC 1295 ft.0.6$ 894$ 0.03 2,914$ 2" PVC 3540 ft.0.4$ 1,628$ 0.03 7,965$ Trenching/Backfilling 3115 ft.2.1$ 7,523$ 0.08 18,690$ Switch Cabinets 1 ea.12,000.0$ 13,800$ 84 6,300$ Primary Junction Box 7 ea.7,000.0$ 56,350$ 24 12,600$ 1 Phase Transformer 5 ea.5,000.0$ 28,750$ 24 9,000$ 3 Phase Transformer 4 ea.10,000.0$ 46,000$ 24 7,200$ 15KV, No. 350 3600 ft.7.50$ 31,050$ 0.07 18,900$ No. 350 XHHW 1200 ft.5.55$ 7,659$ 0.05 4,500$ No. 4/0 XHHW 2135 ft.4.30$ 10,558$ 0.04 6,405$ 10 Pair Telephone Cable 1110 ft.4$ 5,106$ 0.02 1,665$ Cable TV Cables 1400 ft.4$ 6,440$ 0.02 2,100$ Secondary Service 15 ea.250$ 4,313$ 8.00 9,000$ Television Service 16 ea.150$ 2,760$ 8.00 9,600$ Telephone Service 13 ea.150$ 2,243$ 8.00 7,800$ Primary Cutovers 3 ea.7,500$ 25,875$ 48.00 10,800$ Television Cutovers 3 ea.1,500$ 5,175$ 24.00 5,400$ Telephone Cutovers 3 ea.1,500$ 5,175$ 24.00 5,400$ Demo Poles & Overhead 8 ea.1,500$ 13,800$ 64.00 38,400$ 270,842$ 165,874$ Total - 488,916$ Contingency (30%)81,253$ 49,762$ 146,675$ Profit (10%)27,084$ 16,587$ 48,892$ Total - Power Labor & Materials 379,179$232,223$684,482$ WML&P Overhead & Inspection 10%68,448$ Total Utility Work 752,931$ In-Kind 19,320$ 53,761$ 141,529$ Grant 611,402$ Page 1 MORRIS ENGINEERING GROUP, LLC s PRELIMINARY CONSTRUCTION COST ESTIMATE PROJECT:Front Street STA 19+50 to 23+50 (Episcopal St. to Case Avenue) JOB #:129-03 Date:11/04/09 Relocate all overhead to underground Labor multiplier 1.5 Labor rate 50 Materials multiplier 1.15 Material/Task Quantity Unit Cost Material Labor Labor Subtotals Total Total 6" PVC 1480 ft.2.0$ 3,404$ 0.05 5,550$ 4" PVC 2220 ft.1.0$ 2,553$ 0.04 6,660$ 2-1/2" PVC 900 ft.0.6$ 621$ 0.03 2,025$ 2" PVC 2000 ft.0.4$ 920$ 0.03 4,500$ Trenching/Backfilling 2000 ft.2.1$ 4,830$ 0.08 12,000$ Switch Cabinets 1 ea.12,000.0$ 13,800$ 84 6,300$ Primary Junction Box 3 ea.7,000.0$ 24,150$ 24 5,400$ 1 Phase Transformer 3 ea.5,000.0$ 17,250$ 24 5,400$ 15KV, No. 350 2400 ft.7.50$ 20,700$ 0.07 12,600$ No. 350 XHHW 800 ft.5.55$ 5,106$ 0.05 3,000$ No. 4/0 XHHW 2592 ft.4.30$ 12,817$ 0.04 7,776$ 10 Pair Telephone Cable 590 ft.4$ 2,714$ 0.02 885$ Cable TV Cables 800 ft.4$ 3,680$ 0.02 1,200$ Secondary Service 10 ea.250$ 2,875$ 8.00 6,000$ Television Service 7 ea.150$ 1,208$ 8.00 4,200$ Telephone Service 8 ea.150$ 1,380$ 8.00 4,800$ Primary Cutovers 3 ea.7,500$ 25,875$ 48.00 10,800$ Television Cutovers 3 ea.1,500$ 5,175$ 24.00 5,400$ Telephone Cutovers 3 ea.1,500$ 5,175$ 24.00 5,400$ Demo Poles & Overhead 3 ea.1,500$ 5,175$ 64.00 14,400$ 154,233$ 109,896$ Total - 283,704$ Contingency (30%)46,270$ 32,969$ 85,111$ Profit (10%)15,423$ 10,990$ 28,370$ Total - Power Labor & Materials 215,926$ 153,854$ 397,186$ WML&P Overhead & Inspection 10%39,719$ Total Utility Work 436,904$ In-Kind 7,246$ 20,160$ 67,125$ Grant 369,779$ Page 1