Loading...
HomeMy WebLinkAboutAEA Statement of InterestStatement of Interest In Developing an Alaskan Altemative-Renewable Energy or Energy Efficiency Project Project Title: Archangel Hydroelectric Project Organization: Jill Reese Investments and Green Power Development Contact Name: Dan Hertrich Address: 1503 W. 33 m Avenue, Suite 310 Phone Number: 907-258-2420 Fax: 907-258-2419 City: Anchorage I State: AK I Zip Code: 99503 Email: dan@polarconsult.net Instructions: Complete the information requested on this page. On page two, provide the following information: • At the top left, enter the Project Name with the Contact Name with the Contact name under it on the next line. • Respond to the following:; 1. State the problem being addressed by this project. 2. List the program objectives. 3. What will be the impact to Alaska if this project is successful? That is, can the project be extended to other locations or applications? 4. Give a brief statement of your work plan. 5. Any other pertinent information, e.g., review processes the project has been through, fundinQ match-if any, etc. Executive Project Description (Highlights of project) The Archangel Hydroelectric Project is a run-of-river hydroelectric project located in Hatcher Pass on Archangel Creek. The project would have 490 feet of gross head, a design flow of 60 cfs, and a peak output of 1.7 MW. Average annual energy from the project would be 7,700 MWh. Power would be sold to Mata.nuska Electric Association. Funding for the powerline line extension to the Motherlode Logde (powerhouse site] is required to begin permitting, design, and construction. To date, project surveying, feasibility, and conceptual design have been completed. Project Cost Estimate & Schedule a) Design Costs b) Land, Right-of-way c) Administration d) Construction e) Equipment f) Other TOTAL Other Participants 300000 50000 70000 5500000 500000 6420000 Duration of Activity Type of Project under Consideration months) 12 12 24 6 18 36 36 ~ Alternative Energy D Feasibility ~ Design ~ Construction D Other (describe), D Energy Efficiency D Resource Assessment D Prototype D Operations Name: Organization: Phone: Email: Name: Organization: Phone: Email: Name: Organization: Phone: Email: Project Title: Archangel Hydroelectric Project Organization: Jill Reese Investments and Green Power Development Detailed Project Statement: Project Access: The project would be accessed from the existing Fern Mine Road. A construction trail would be built from the Lower Fern Mine Road approximately 650 feet to the intake location. A construction trail would continue from the intake approximately 7,750 feet to the powerhouse. Project Intake: The project intake would consist of a small diversion structure across Archangel Creek near the confluence with Reed Creek. Project water would be diverted into a desanding box that would filter the water to remove any gravel, sand, silt, or organic detritus harmful to the turbines. The desanding box would be designed to handle approximately 60 cubic feet per second (cfs) of water, and would be designed to blend into the natural surroundings. Project Penstock: The penstock would likely consist of 36" diameter high density polyethylene (HOPE) plastic pipe and 10 gauge steel pipe. Conduit to run secondary power and controls wiring to the intake would be buried along with the penstock. Project Powerhouse and Tailrace: The project powerhouse would be located near the outlet of Archangel Creek into the Little Susitna River. The powerhouse would be painted to blend into surrounding vegetation. The tailrace would be constructed of native materials and would return project water to Archangel Creek. Transmission Line: The project transmission line would be a 7,200 volt 3 phase line. The transmission line would be buried where feasible. The line would parallel the eXisting footpath along the Little Susitna River approximately 2,500 feet to Fishhook Road near the Motherlode Lodge. From there, the line would parallel Fishhook Road south for approximately 2.7 miles until it reached the existing Matanuska Electric Association distribution line.