HomeMy WebLinkAbout17S Brochure.L
; L I
�doo-
Money's in the air
The forces of nature are far beyond
human control, however, some of them
we are able to control and transform into
energy. From natural sources we derive,
among other things, lighting and heating,
and those are the factors which keep the
whole economy working.
In some states water power forms the
basis for natural energy. In other states,
like California for instance, wind power is
the natural energy source.
Actually, the California wind means that
millions of kilowatt hours are floating about
in the air, so really, it is only a question
of harnessing them.
The advanced Wind Matic windmill
renders this possible through an invest-
ment which is not only financially profit-
able, but also an extremely solid way to
save energy money. In areas which are
particularly wind-swept it would be almost
unwise not to utilize the wind energy.
Wind Matic WM 17 S means a
safe investment in the future
Here are some facts
which speak for investing in windmills
Wind power: The investment. It would
be an understatement to say that wind
power represents a favorable investment
opportunity. In fact, thanks to several
factors, wind power is one of the most
attractive investment opportunities ever
offered to the private investor.
Wind power is ,pre -sold ,. Federal and
state law require utility companies to pur-
chase all the power that wind generation
can produce. That means that every
single watt of wind -produced electricity is
guaranteed a market! Better still, the utili-
ty companies are required to purchase
wind -generated power at the ,highest
avoided cost- - that is, the maximum rate
they would have to pay for conventionally -
produced power.
Here are some facts
which speak for investing in Wind Matic
Wind Matic A/S has more than 10
years experience in development and
production of windmills and is the Danish
company which has the best knowledge
in this field. The Wind Matic windmill
occupies a prominent position because of
the advanced technology and design of
the windmill and because the cornpo-
nents used are of high quality. All factors
which ensure a reliable, effective opera-
tion and a very long life, including very
little maintenance.
YRT� The result of
many years of research and
development
The Wind Matic 17 S has been devel-
oped on the basis of the WM 15 S.
The Wind Matic 17 S is the latest devel-
opment in our S-series and thus it is con-
structed with the purpose of obtaining a
higher power output. The WM 17 S is
equipped with advanced computer steer-
ing, based on micro -processor techno-
logy.
The annual energy yield of the windmill
is dependent on the wind conditions of
the site in question and of course the plac-
ing of the windmill.
The power of the WM 17 S can be read
from the power curve below. (Power curve
measured by an impartial authority
,Jest Plant for Smaller Windmills, Riso«).
$ Projected income kilowatt hours per year
40,000
35,000
30,000
25,000
20,000
15,000
10,000
200,000 250,000 300,000 350,000 400,000 kW
6.5 c/kW 9 8.5 c/kW ■ 10.5 c/kW
Power Curve WM 17 S USA
_ Standard airdensity = 1.23 kg/m3
Pe (kW)
100
90
80
70
60
50
40
30
20
10
5 10 15 20 25 30 (M/S)
11,2 22,4 33,6 44,7 56,0 67,1 (MPH)
Strong
and reliable
1) The turbine has been constructed in
a way which provides you with the
possibility of fine adjustment of the
tip angle in accordance with the
conditions. The turbine is mounted
on a forged shaft, supported by two
heavy-duty, spherical roller
bearings.
2) When designing the aerofoil empha-
sis was placed on obtaining a higher
power output. The blades are made
of fiberglass reinforced Polyester,
built up around a reinforced main
beam with an imbedded root of
heat -treated SG -iron.
3) Each blade is equipped with a spoil-
er type independent aerodynamic
brake, providing a secondary braking
system.
Sturdy quality down to
details
The hub is a welded, heavy-duty
construction, bolted to the flange
on the main shaft.
MW
NOW
The windmill is equipped with an
operation brake on the slowrevolving
shaft. A fact which means that the
gearbox will not be exposed to large
mechanical loads when breakina.
The nacelle rotates on four self -
greasing Oilon blocks, mounted
between the cabin and the yaw
gear wheel.
Between the gearbox and the
generator a flexible coupling, free
of maintenance, is mounted.
The yawing system functions by
means of a yaw motor and a yaw
gear which keeps the windmill
oriented to the wind direction.
The yaw motor is controlled by
means of wind vane signals.
CMTQ( ha-s built-in electronic
supervision, providing maximum
security
The control system of the WM 17 S is
based on advanced microprocessor
technology.
The system supervises and controls
both the grid and the windmill and will
bring the windmill to an immediate halt if
any irregularity should arise:
1. Abnormal variations in grid frequency
and grid voltage.
2. Overspeed on main and/or generator
shaft.
3. Transmission error between large
and small generator.
4. Breaking of phase between large and
small generator.
5. Thermal overload of generators (tem-
peratures measured on two levels).
6. Thermal overload of yaw motor.
7. Thermal overload of gearbox.
8. Abnormal vibrations.
9. Max. yawing period exceeded.
10. Level too low in brake fluid reservoir.
11. Oil level too low in gearbox.
12. Worn brake blocks.
13. Abnormal twisting of cables (automatic
un-twisting).
Technical specifications
WM 17 S
14. Wind speed higher than cut-out
speed.
When the points stated in 13 and 14
are corrected, the computer control will
re -start the windmill automatically. Thyri-
stor control from the computer ensures a
careful, soft connection to the grid.
A display on the control panel indicates
any irregularity by the windmill operation
or by the grid. Also, other factors such as
wind speed, electric power, and the RPM,
will appear from the display. This control
system also gives you the possibility of
connecting a computer for central super-
vision.
CONNECTION TO MAINS
AERODYNAMIC BRAKES
Small generator
Voltage
480 V
Type
spoilers
Rated electrical power
20 kW
Frequency
60 Hz
Realeasing
centrifugally
Rated RPM
1225 RPM
PERFORMANCE
NACELLE
Large generator
Cut -in wind speed
3.5 m/s
Cover material
aluminium
Rated electrical power
95 kW
Wind speed for power
15 m/s
Chassis material
hot dip galvanized
Rated RPM
1213 RPM
Cut-out wind speed
25 m/s
steel
CONNECTION BETWEEN LARGE AND SMALL
Design wind speed
50 m/s
Dimensions (length x width
GENERATOR
Max. electric power
95 kW
x height)
2690 x 1325 x
Type
V-belt
(10 minutes average values)
1320 mm
transmission
TURBINE
Mass (excl. turbine)
4100 kg
Gear ratio
1 :1.42
Type
3 blades, stall
MAIN BEARINGS
YAWING SYSTEM
regulated up wind
Type
spherical roller
Type
outside toothed
turbine
bearings
yaw gear wheel
Diameter
17.0 m
Number
2
and oilon
Direction of rotation
counterclockwise
OPERATION BRAKE
bearings
RPM
40-41/57-58 RPM
Type
disc brake
Operation
on/off electrical
Tilt angle
50
Location
rotor shaft
control of yawing
Cone angle
0o
Operation
hydraulic
motor from wind
Mass (incl. hub)
1240 kg
GEARBOX
vane signals
BLADES
Type
oil lubricated,
Yawing period
0.8°/sec.
Blade suspension
selfsupported
hollow shaft
CONTROL SYSTEM
Beam material
reinforced fiber-
Number of stages
3
Type
electrical, based
glass Polyester
Gear ratio
1:20.73
on micro-proces-
with steel root
Rated power
190 kW (DIN)
sors
Shell material
reinforced fiber-
COUPLING
Function
control, super -
glass Polyester
Type
flexible rubber
vising, connection
Aerofoil
NACA 63-200
coupling
p g
of generators
Pitch
fixed
b.m.o. thyristors
Length
8.20 m
GENERATORS
Type
asynchronous
with squirrel cage
MUT9
Six various types of towers
You can choose between a steel lattice
tower or a tube tower and each of these
types gives you the choice between three
different heights - 60, 72 or 80 ft.
Which height of tower chosen depends
on the conditions of the site in question.
60 ft
72 ft
72 ft
The steel lattice tower is solidly con-
structed of hot dip galvanized round iron
and the tube tower is hot dip galvanized
milled tank plates.
There is always a 80 ft
Wind Matic windmill which fits
Irrespective of energy needs there is al- professional Danish Windmill Company.
ways a Wind Matic windmill which fits - - You can depend on the Wind Matic
and remember, the Wind Matic windmills windmill.
are all fully developed products from the