HomeMy WebLinkAboutGorman Rupp GMC Data SheetsROTARY GEAR PUMPS MEDIUM DUTY COMPACT ROTARY GEAR PUMP GMC SERIES SEC. 520 PAGE 100 June 2003 PUMP SPECIFICATION BULLETIN FEATURES OPERATING RANGE APPLICATIONS 200 PSI CAPABILITY COMPACT-NEMA C MOUNTING -- NO DRIVE COUPLING OR GUARD ACCURATE ALIGNMENT INEXPENSIVE PUMP/DRIVE UNIT THRUST CONTROLLED PUMP ELEMENTS LONG LIFE -- QUIET OPERATION MULTIPLE PORT POSITIONING CAPACITY (GPM): (3 TO 38) [LPM] : [11 TO 144] PRESSURE (PSI) : (0 TO 200) [BAR] : [0 TO 14] VISCOSITY (SSU) : (28 TO 250,000) [cSt] : [1 TO 55,000] TEMPERATURE (F) : (--40_TO 300_) [C] : [--40_TO 149_] USE WITH ANY CLEAN LIQUID COMPATIBLE WITH CAST IRON BOOSTER SERVICE CIRCULATING FILTERING LUBRICATING TRANSFERRING SUPERSEDES ALL PREVIOUS ISSUES The GMC series is designed for applications in the operating ranges noted below. Direct connectingto otherpieces of equipment provides an extremely compact system design. The six sizes of Gorman-Rupp close coupled pumps connect to standard NEMA “C” flanges. Rotor shaft bores accept standard motor shafts; 5/8” standard, 7/8”, 1-1/8” and 1-3/8” are optional. Metric coupling also available. At synchronous speeds, extra drive equipment, including couplings or outboard bearings, is not required. For continuous service, or for handling viscous liquids, see the heavy duty GHS section. THE GORMAN-RUPP COMPANY DDDD MANSFIELD, OHIO GORMAN-RUPP OF CANADA LIMITED DDDD ST. THOMAS, ONTARIO, CANADA E Copyright by the Gorman-Rupp Co. LIPSEAL MAXIMUM INLET PRESSURE (PSI [BAR] ) OPTIONS MAXIMUM TEMPERATURE VISCOSITY (SSU [cSt] ) RANGE (_F[_C] ) STD 15 [1] 25,000 [5,500] --50 to 225 [--45 to 107] 65A 15 [1] 25,000 [5,500] 0 to 350 [--17 to177] 65C 100 [7] 250,000 [55,000] 0 to 350 [--17 to177] MAXIMUM INLET PRESSURE (PSI [BAR] ) NON-LUBRICATING LUBRICATING LIQUID LIQUID LIPSEALMECH. SEAL Standard Construction Standard Models G M C 1 DC 3 --- B GEAR DUTY DESIGN PORT- SIZE SEAL STYLEHYDRAULIC SIZE MAXIMUM ALTERNATIVE DIFFERENTIAL PRESSURE -- PSI [BAR] TEMP. NOM. CAPACITY -- SPEED MAXIMUM MODEL NUMBER GMC 1DC 3-B GMC 1DC 4-B GMC 1DE3-B GMC 1DE4-B GMC 1-1/2GC 3-B GMC 1-1/2GC 4-B GMC 2GC 3--B GMC 2GC 4--B GMC 1-1/2GF 3-B GMC 1-1/2GF 4-B GMC 2GF 3--B GMC 2GF 4--B GMC 1-1/2GH 3-B GMC 1-1/2GH 4-B GMC 2GH 3--B GMC 2GH 4--B GMC 1-1/2GJ 3--B GMC 1-1/2GJ 4--B GMC 2GJ 3-B GMC 2GJ 4-B 96 [28] [19] 20 [9,0] 20 [9,0] 32 [14,5] 32 [14,5] 32 [14,5] 32 [14,5] 32 [14,5] 32 [14,5] 32 [14,5] 32 [14,5] 11 7 [35] [22] 16 10 [50] [32] 23 1750 15 1150 [73] [1460] [47] [960] 300 [149] 31 20 [98] [63] 100 150 200 [7] [10] [14] 38 25 [120] [79] 225 [107] GMC, SEC. 520: PAGE 101 June 2003 SUPERSEDES ALL PREVIOUS ISSUES NOTE:RECOMMENDED PORT SIZES ARE SHOWN IN BOLDFACE.Example:GMC 2GJ 3-B MECH. SEAL OPTIONS STD 100 [7] 150 [10.5] 15,000 [3250] 0 to 400 [--17 to 204] 60A 100 [7] 150 [10.5] 15,000 [3250] --50 to 225 [--45 to107] 61J 100 [7] 200 [14] 15,000 [3250] 0 to 400 [--17 to 204] GPM RPM GPM RPM BELOW 38 TO 100 TO _F 60 Hz 60 Hz 38 SSU 100 SSU 250,000 SSU [LPM] [50 HZ] [LPM] [50 Hz] [4 cSt] [21 cSt] [55,000 cSt] [_C] MAXIMUM TEMPERATURE VISCOSITY (SSU [cSt] ) RANGE (_F[_C] ) BUSHINGS SHAFT ROTATION ROTOR SHAFT SEALING & IDLER EXTER- HOUSING IDLER IOR PORTS PIN INTERNAL RELIEF VALVE MATERIAL SETTING CAST 180_HARDENED DUCTILE 75 PSI IRON TAPPED STEEL IRON [5 BAR] BRONZE STEEL VITON BUNA-N C.W. SEAL LIMITATIONS: SHIPPING DATA Weight Volume LBS CU. [KG] FT. 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 NOTE: PROPER PUMP APPLICATION REQUIRES CONSIDERATION OF ADDITIONAL FACTORS. PLEASE REVIEW CHALLENGING APPLICATIONS IN SECTION 500 AND THE LIQUIDS LIST IN THE ROTARY GEAR REFERENCE GUIDE. IRON HIGHSTRENGTH THE GORMAN-RUPP COMPANY DDDD MANSFIELD, OHIO GORMAN-RUPP OF CANADA LIMITED DDDD ST. THOMAS, ONTARIO, CANADA E Copyright by the Gorman-Rupp Co. 1 ROTATION C.W. (VIEWED FROM SHAFT END) Options 2 MATCH BOLDFACE OPTIONSWITH BOLDFACE MODELS. EX:GMC 2GJ 3B OPT. 05D CHANGES PORT TO 90_ GMC 1--1/ 2GJ 3B OPT. 05B CHANGES PORT TO 90_ 1 180_PORT HOUSINGS WITH 2 RELIEF VALVES RECOMMENDED. MUST HAVE SELECTED 90_OPTION FROM CATEGORY 05 (HOUSING PORTS) TO SELECT FROM THIS COLUMN. 180_PORT HOUSINGS REQUIRED. MUST SELECT BI--ROTATION OPTION 01B. DO NOT ALLOW DISCHARGE PRESSURE TO EXCEED RATED SEAL PRESSURE. SEE SEAL LIMITATION TABLE. 180_ (3 SUCTION -- 9 DISCHARGE) (VIEWED FROM SHAFT END) HOUSING PORT CLOCK POSITION 180_(3--9)90_(3--12) 3 4 2 OPTIONS CONTINUED 01A C.C.W. 01B BI--ROTATION 05A DC, DE 1” NPT -- 90_ 05B GC, GF, GH,GJ 1-1/2”NPT--90_ 05D GC, GF, GH,GJ 2” NPT -- 90_ 15A 12--9 GMC, SEC. 520: PAGE 102 June 2003 LOW PRESSURE RELIEF VALVE DUCTILE IRON/VITON 90_HEAD MOUNT 180_HOUSING MOUNT RELIEF VALVE 25A HIGH PRESSURE 25C LESS RELIEF VALVE 25D 2 VALVES -- LOW PRESSURE 25E 2 VALVES -- HIGH PRESSURE 25G RETURN TO TANK -- LOW PRESSURE, NEOPRENE O--RING 25H RETURN TO TANK -- HIGH PRESSURE, NEOPRENE O--RING 25J LOW PRESSURE, TEFLON ENCAPSULATED O--RING 25K HIGH PRESSURE, TEFLON ENCAPSULATED O--RING 25L LESS RELIEF VALVE, TEFLON ENCAPSULATED O--RING 3 FOR CRACKING PRES- SURE RANGES REFER TO SECTION 500, PG 18 3 TBS HOUSING PORTS 180_HOUSING HYDRAULIC SIZE PORT BUSHING BUSHING LIMITATIONS: Temp Limit,Bushing Material Optimal Viscosity Range _F[C] Abrasives Corrosives STD, 40B 100 TO 100,000 SSU 400 [205] No No 40C 0.1 cPs to 2,000,000 SSU 400 [205] No Yes * 40U 0.1 cPs to 2,000,000 SSU 400 [205] Yes Yes * Note:*Consult chemical compatibility charts for new applications. 4 CATEGORY STANDARD OPTIONAL NUMBER & DESCRIPTION THE GORMAN-RUPP COMPANY DDDD MANSFIELD, OHIO GORMAN-RUPP OF CANADA LIMITED DDDD ST. THOMAS, ONTARIO, CANADA E Copyright by the Gorman-Rupp Co. SUPERSEDES ALL PREVIOUS ISSUES 65A LIPSEAL -- VITON 65C LIPSEAL -- VITON, HEAVY DUTY GMC, SEC. 520: PAGE 103 June 2003 Options (Continued) 56C MOTOR FRAME REQUIRES 5/8” BORE SHAFT. USE STANDARD 50 OR OPTIONAL 50H. 143TC, 145TC, 182C AND 184C MOTOR FRAMES REQUIRE 7/8 BORE SHAFT. SELECT OPTION 50A OR 50J. “G” HYDRAULIC SIZE ONLY:182TC, 184TC, 213C AND 215C MOTOR FRAMES REQUIRE 1-1/8 BORE SHAFT. MUST SELECT OPTION 70A AND OPTION 50B or 50K. “G” HYDRAULIC SIZE ONLY:213TC, 215TC, AND 254C MOTOR FRAMES REQUIRE 1-3/8 BORE SHAFT. MUST SELECT OPTION 70A AND OPTION 50C or 50L. MAX. VISCOSITY 15,000 SSU. MAX DIFFERENTIAL 100 PSI. 24 mm BORE IS FOR AE90, 28 mm BORE IS FOR AE100/112. IN EITHER CASE, MUST SELECT ADAPTOR 70A. 50A 7/8” BORE 50B 1-1/8” BORE 50C 1-3/8” BORE 50D 24 mm BORE 50E 28 mm BORE 50F BRONZE/STEEL -- 24 mm BORE 50G BRONZE/STEEL -- 28 mm BORE 50H BRONZE/STEEL -- 5/8” BORE 50J BRONZE/STEEL -- 7/8” BORE 50K BRONZE/STEEL -- 1-1/8” BORE 50L BRONZE/STEEL -- 1-3/8” BORE HIGH STRENGTH IRON/ STEEL 5/8” BORE ROTOR / SHAFT 2 3 4 2 1 3 4 SEAL LIPSEAL -- BUNA--N MECH. SEAL FRICTION DRIVE -- CARBON, CERAMIC, VITON 60A FRICTION DRIVE -- CARBON, CERAMIC, BUNA--N 61J FRICTION DRIVE -- SiC, SiC, VITON 70A BACKHEAD ADAPTER MOTOR MOUNTING DIAMETER 8-1/2” FOR MOTOR FRAMES 182TC, 184TC, 213C, 215C FOR MOTOR FRAMES 213TC, 215TC, 254C 4-1/2” -- MOTOR FRAMES 56C, 143TC, 145TC, 182C, 184C BACKHEAD MOTOR MOUNTING DIAMETER 1 CONSULT FACTORY FOR ADDITIONAL OPTIONS Consult factory for optional backhead thrust washer materials. 5 5 5 5 3 4 1 2 3 4 5 40B BRONZE IDLER GEAR 40C CARBON GRAPHITE IDLER BUSHING 40U SILICON CARBIDE IDLER BUSHING CAST IRON HIGH STRENGTH IRON BRONZE HEAD IDLER IDLER BUSHING 35C C TRIM (VISCOSITY) 35D D TRIM (VISCOSITY) GEAR TRIM NO TRIM FOR VISCOSITY TRIM CHART REFER TO SECTION 500, PAGE 20. (TRIM ACCORDING TO VISCOSITY; CONTACT DISTRIBUTOR OR FACTORY.) CATEGORY STANDARD OPTIONAL NUMBER & DESCRIPTION THE GORMAN-RUPP COMPANY DDDD MANSFIELD, OHIO GORMAN-RUPP OF CANADA LIMITED DDDD ST. THOMAS, ONTARIO, CANADA E Copyright by the Gorman-Rupp Co. SUPERSEDES ALL PREVIOUS ISSUES 5 6 5 6 6 6 6