Loading...
HomeMy WebLinkAbout17S Brochure.L ; L I �doo- Money's in the air The forces of nature are far beyond human control, however, some of them we are able to control and transform into energy. From natural sources we derive, among other things, lighting and heating, and those are the factors which keep the whole economy working. In some states water power forms the basis for natural energy. In other states, like California for instance, wind power is the natural energy source. Actually, the California wind means that millions of kilowatt hours are floating about in the air, so really, it is only a question of harnessing them. The advanced Wind Matic windmill renders this possible through an invest- ment which is not only financially profit- able, but also an extremely solid way to save energy money. In areas which are particularly wind-swept it would be almost unwise not to utilize the wind energy. Wind Matic WM 17 S means a safe investment in the future Here are some facts which speak for investing in windmills Wind power: The investment. It would be an understatement to say that wind power represents a favorable investment opportunity. In fact, thanks to several factors, wind power is one of the most attractive investment opportunities ever offered to the private investor. Wind power is ,pre -sold ,. Federal and state law require utility companies to pur- chase all the power that wind generation can produce. That means that every single watt of wind -produced electricity is guaranteed a market! Better still, the utili- ty companies are required to purchase wind -generated power at the ,highest avoided cost- - that is, the maximum rate they would have to pay for conventionally - produced power. Here are some facts which speak for investing in Wind Matic Wind Matic A/S has more than 10 years experience in development and production of windmills and is the Danish company which has the best knowledge in this field. The Wind Matic windmill occupies a prominent position because of the advanced technology and design of the windmill and because the cornpo- nents used are of high quality. All factors which ensure a reliable, effective opera- tion and a very long life, including very little maintenance. YRT� The result of many years of research and development The Wind Matic 17 S has been devel- oped on the basis of the WM 15 S. The Wind Matic 17 S is the latest devel- opment in our S-series and thus it is con- structed with the purpose of obtaining a higher power output. The WM 17 S is equipped with advanced computer steer- ing, based on micro -processor techno- logy. The annual energy yield of the windmill is dependent on the wind conditions of the site in question and of course the plac- ing of the windmill. The power of the WM 17 S can be read from the power curve below. (Power curve measured by an impartial authority ,Jest Plant for Smaller Windmills, Riso«). $ Projected income kilowatt hours per year 40,000 35,000 30,000 25,000 20,000 15,000 10,000 200,000 250,000 300,000 350,000 400,000 kW 6.5 c/kW 9 8.5 c/kW ■ 10.5 c/kW Power Curve WM 17 S USA _ Standard airdensity = 1.23 kg/m3 Pe (kW) 100 90 80 70 60 50 40 30 20 10 5 10 15 20 25 30 (M/S) 11,2 22,4 33,6 44,7 56,0 67,1 (MPH) Strong and reliable 1) The turbine has been constructed in a way which provides you with the possibility of fine adjustment of the tip angle in accordance with the conditions. The turbine is mounted on a forged shaft, supported by two heavy-duty, spherical roller bearings. 2) When designing the aerofoil empha- sis was placed on obtaining a higher power output. The blades are made of fiberglass reinforced Polyester, built up around a reinforced main beam with an imbedded root of heat -treated SG -iron. 3) Each blade is equipped with a spoil- er type independent aerodynamic brake, providing a secondary braking system. Sturdy quality down to details The hub is a welded, heavy-duty construction, bolted to the flange on the main shaft. MW NOW The windmill is equipped with an operation brake on the slowrevolving shaft. A fact which means that the gearbox will not be exposed to large mechanical loads when breakina. The nacelle rotates on four self - greasing Oilon blocks, mounted between the cabin and the yaw gear wheel. Between the gearbox and the generator a flexible coupling, free of maintenance, is mounted. The yawing system functions by means of a yaw motor and a yaw gear which keeps the windmill oriented to the wind direction. The yaw motor is controlled by means of wind vane signals. CMTQ( ha-s built-in electronic supervision, providing maximum security The control system of the WM 17 S is based on advanced microprocessor technology. The system supervises and controls both the grid and the windmill and will bring the windmill to an immediate halt if any irregularity should arise: 1. Abnormal variations in grid frequency and grid voltage. 2. Overspeed on main and/or generator shaft. 3. Transmission error between large and small generator. 4. Breaking of phase between large and small generator. 5. Thermal overload of generators (tem- peratures measured on two levels). 6. Thermal overload of yaw motor. 7. Thermal overload of gearbox. 8. Abnormal vibrations. 9. Max. yawing period exceeded. 10. Level too low in brake fluid reservoir. 11. Oil level too low in gearbox. 12. Worn brake blocks. 13. Abnormal twisting of cables (automatic un-twisting). Technical specifications WM 17 S 14. Wind speed higher than cut-out speed. When the points stated in 13 and 14 are corrected, the computer control will re -start the windmill automatically. Thyri- stor control from the computer ensures a careful, soft connection to the grid. A display on the control panel indicates any irregularity by the windmill operation or by the grid. Also, other factors such as wind speed, electric power, and the RPM, will appear from the display. This control system also gives you the possibility of connecting a computer for central super- vision. CONNECTION TO MAINS AERODYNAMIC BRAKES Small generator Voltage 480 V Type spoilers Rated electrical power 20 kW Frequency 60 Hz Realeasing centrifugally Rated RPM 1225 RPM PERFORMANCE NACELLE Large generator Cut -in wind speed 3.5 m/s Cover material aluminium Rated electrical power 95 kW Wind speed for power 15 m/s Chassis material hot dip galvanized Rated RPM 1213 RPM Cut-out wind speed 25 m/s steel CONNECTION BETWEEN LARGE AND SMALL Design wind speed 50 m/s Dimensions (length x width GENERATOR Max. electric power 95 kW x height) 2690 x 1325 x Type V-belt (10 minutes average values) 1320 mm transmission TURBINE Mass (excl. turbine) 4100 kg Gear ratio 1 :1.42 Type 3 blades, stall MAIN BEARINGS YAWING SYSTEM regulated up wind Type spherical roller Type outside toothed turbine bearings yaw gear wheel Diameter 17.0 m Number 2 and oilon Direction of rotation counterclockwise OPERATION BRAKE bearings RPM 40-41/57-58 RPM Type disc brake Operation on/off electrical Tilt angle 50 Location rotor shaft control of yawing Cone angle 0o Operation hydraulic motor from wind Mass (incl. hub) 1240 kg GEARBOX vane signals BLADES Type oil lubricated, Yawing period 0.8°/sec. Blade suspension selfsupported hollow shaft CONTROL SYSTEM Beam material reinforced fiber- Number of stages 3 Type electrical, based glass Polyester Gear ratio 1:20.73 on micro-proces- with steel root Rated power 190 kW (DIN) sors Shell material reinforced fiber- COUPLING Function control, super - glass Polyester Type flexible rubber vising, connection Aerofoil NACA 63-200 coupling p g of generators Pitch fixed b.m.o. thyristors Length 8.20 m GENERATORS Type asynchronous with squirrel cage MUT9 Six various types of towers You can choose between a steel lattice tower or a tube tower and each of these types gives you the choice between three different heights - 60, 72 or 80 ft. Which height of tower chosen depends on the conditions of the site in question. 60 ft 72 ft 72 ft The steel lattice tower is solidly con- structed of hot dip galvanized round iron and the tube tower is hot dip galvanized milled tank plates. There is always a 80 ft Wind Matic windmill which fits Irrespective of energy needs there is al- professional Danish Windmill Company. ways a Wind Matic windmill which fits - - You can depend on the Wind Matic and remember, the Wind Matic windmills windmill. are all fully developed products from the