HomeMy WebLinkAbout1 I Eagle Electric ProfileEagle Electric LLC
A Subsidiary of Bering Straits Native Corporation 6937 Old Seward Highway
Anchorage, Alaska 99507
907.344.7121 ♦ 907.344.0827 Fax
Eagle Electric is pleased to submit the following Corporate Profile.
Eagle Electric is part of the Bering Straits Native Corporation family of companies. We are
committed to partnership that benefits both our shareholders and thebroader community in
which we both serve.We actively pursue our commitment to improve the quality of life of our
people, protect our land, and preserve our culture and heritage.
Eagle Electric’s commitment includes offering training and employment opportunities to Alaska
natives and tribal members. Eagle Electric provides an apprentice program in conjunction with
Kawerak, Inc. Kawerak's organizational goal is to assist Alaska Native people to take control of
their future. With programs ranging from education to housing, and natural resource
management to economic development, Kawerak seeks to improve the Region's social,
economic, educational, cultural and political conditions.
Eagle Electric supports Kawerak’s Education Employment and Training division, which is
designed to provide support and assistance to tribal members who are looking for job training
while they are continuing their education. The purpose of these programs is to provide applicants
the opportunity to gain work experience, promote good work ethics and provide a public service
to their community.Fifty-percent of Eagle Electric’s employees in Nome have been trained in
this Kawerak division.
In addition, Eagle Electric is actively involved in developing a new training program with
Kawerak to train village residents. In 2001, Kawerak began the implementation of village-based
skills training programs. These 2-4 week programs are designed for apprentices and are
registered by the federal Department of Labor.Each training program uses a standard curriculum
that is approved by the National Center for Construction Education and Research (NCCER).
Participants earn college-credit through Northwest College/University of Alaska.
To be successful in any industry, quality is of the utmost importance. We offer more than
satisfactory service, with the goal of becoming the service provider of choice. Our reputation is
sustained by making customers active partners. We value working relationships with full and
open communication. It is only through this process we learn our customer’s needs and insure
the highest performance levels and complete customer satisfaction.
We appreciate your interest in partnership with Bering Straits Native Corporation and Eagle
Electric. We look forward to serving with you.
Sincerely,
Michael London,Senior Vice President
Eagle Electric LLC
“Building Our Future”and “Doing It Right”with effective partnerships
Electrical Contractors ▓Commercial, Industrial, Residential, Service & Maintenance ▓Licensed, Bonded & Insured
Eagle Electric LLC
Operations Offices
Licensed
Bonded
Insured
SBA 8(a) Certified
DBE Certified
Overview
Eagle Electric has served 20 years as a construction, renovation, maintenance, and electrical service contractor. In
the early 1980s,the majority of our work was concentrated on residential (single and multi-family housing) to
small/large scale hotel complexes.
Eagle Electric has grown substantially, performing larger commercial, industrial, and military projects. Continued
expansion now involves on-going facility operations and maintenance support services. Our nationwide operations
are now managed from offices in
Nome AK,
Anchorage AK,
Las Vegas NV,
SunnyPoint NC,and
Goose Creek, SC.
Eagle Electric’s growth has resulted in the addition of
trained management personnel,skilled estimators,and
competent project managers.Our management staff has
over 100 years’ cumulative experience in the construction
and services industry. Project leaders have successfully
completed projects that vary in scope and size to over $20M
in construction value.
Goal and Purpose
Eagle Electric is committed to:
(1)Exceptional workmanship,
(2)Competitive pricing,
(3)A successful project—from the verystart,
(4)Responsive performance,
(5)Safety as a primary concern,
(6)Guarantees on electrical systems we install,
(7)Meeting each timeline and project schedule,
(8)complete customer satisfaction,
(9)Professional &friendly relationships, and
(10)Repeat business!
Construction and Service Specializations
Eagle Electric is a full-service firm performing electrical contracting, facility maintenance and operations services.
Our general contracting expertise is in design-build, new construction, renovation, restoration, construction
management, and services work.
Eagle Electric serves as a prime contractor and subcontractor to the U.S. Government Agencies in multiple
capacities. Contracts involve extensive NAS, safety and qualitycontrol requirements and procedures. Eagle Electric
has excelled in meeting regulatoryand safetyrequirements. Current contracts involve:
Electrical System Remodeling and Improvements
Installation and Maintenance of
o Lighting
o Fire Alarm Systems
o Telephone & Data Systems
o Communication Systems
o Emergency Standby Power Systems
o Nurse Call / Emergency Call systems
o Sound and Intercom Systems
Nome AK,
Anchorage AK,
Las VegasNV,
Sunny PointNC,and
Goose Creek, SC.
Professional Affiliations:
Design-Build Institute of America
Construction Financial Management Association
Societyof American MilitaryEngineers
Associated General Contractors of Alaska
Construction Specifications Institute
National Association of Women in Construction
The Alaska 8(a) Association
Eagle Electric LLC
“Building Our Future”and “Doing It Right”with effective partnerships
Electrical Contractors ▓Commercial, Industrial, Residential, Service & Maintenance ▓Licensed, Bonded & Insured
o Switchgear
o Electrical Testing
o Electrical Distribution
o Electrical Transf er Station Installations
Roadwayand Grounds Improvements
Fiber Optic Systems Installation
Switchgear Installation
Current & Recently Completed Projects
INDUSTRIAL
Baroid (Halliburton)Prudhoe Bay, Alaska
Prudhoe Bay Mud Plant Expansion & New Motor Control Centers & related electrical
Cooper Industries Prudhoe Bay, Alaska
Industrial Machine Shop Oilfield related equipment i.e.;Blow Out Preventers
Class I Division I & IIExplosion Proof Electrical Installations
Nome Joint Utilities (Alaska Gold)Nome, Alaska
Three mile power line extension to Rock Creek Mine
GOVERNMENT
US Army COE SunnyPoint, NC
Upgrade Deployment Staging & Storage Areas
US Army COE SunnyPoint, NC
River Road Improvements
US Army COE SunnyPoint, NC
North and South Wharf Lighting
Federal Aviation Administration Bettles, Alaska
Flight Service Station Electrical Upgrade
National Parks Service Nome, Alaska
Employee Housing Electrical Upgrade
Bureau of Land Management Anchorage, Alaska
Federal Building Upgrade & Installation of Electrical Office Furnishings
Social Security Administration Anchorage, Alaska
Federal Building Upgrade & Installation of Electrical Office Furnishings
National Park Service.King Salmon, Alaska
Upgrade Lighting
Tunanek Post Office Selawick, Alaska
Electrical Systems Installation for New Construction
Residential Housing Selawick, Alaska
Electrical Systems Installation for New Construction
RESTAURANTS & THEATERS
Benihana Anchorage, Alaska
Tempura Kitchens Anchorage,Alaska
Baskin Robbins Wasilla, Alaska
Gesine’s Anchorage, Alaska
Wayne’s Texas Barbeque Anchorage, Alaska
Peking Restaurant Palmer, Alaska
Bear Tooth Grill & Theater Pub Anchorage, Alaska
Various Espresso Stands in Anchorage & Mat-Su Valley, Alaska
MALLS & SHOPPING CENTERS
CountryVillage Mall Wasilla, Alaska
Tenant Improvements
Eagle Electric LLC
“Building Our Future”and “Doing It Right”with effective partnerships
Electrical Contractors ▓Commercial, Industrial, Residential, Service & Maintenance ▓Licensed, Bonded & Insured
Dimond Center Anchorage, Alaska
Tenant Improvements
Wal*Mart Anchorage, Alaska
Electrical & Lighting Upgrades at two Stores
Payless / Rite-Aid Anchorage,Alaska
Lighting Upgrades at Four Stores
COMMERCIAL BUILDINGS
Hilton Garden Inn Anchorage, Alaska
Installation of Electrical Systems for New Construction of 125 Room Hotel
Dimond Center Hotel Anchorage, Alaska
Installation of Electrical Systems for New Construction of 109 Room Hotel
Big Lake Public Library Big Lake, Alaska
Installation of Electrical Systems for New Construction
Palmer Pioneer Home ADRD Unit Palmer, Alaska
Electrical and Fire Alarm Systems Upgrade and Repair
Security Self Storage Eagle River, Alaska
Installation of Electrical Systems for New Construction
Denali Retail Center Anchorage, Alaska
Wagner Building Anchorage, Alaska
Electrical Upgrades in BLM Offices and Maintenance Shop
Alaska Laser Wash Anchorage, Alaska
Installation of Electrical Systems for New Construction
Merrill Field (General Aviation Airport)Anchorage, Alaska
Twenty-Four Airplane Hangars
Las Vegas CountryClub Las Vegas, Nevada
Installation of Electrical Systems for New Construction & Upgrades to Existing Systems
North West FamilyPark Las Vegas, Nevada
Installation of Electrical Systems for New Construction & Upgrades to Existing Systems
Installation of Electrical Systems for New Construction & Upgrades to Existing Systems
Pioneer Park Las Vegas, Nevada
Installation of Electrical Systems for New Construction & Upgrades to Existing Systems
Fire Station 44 Las Vegas, Nevada
Installation of Electrical Systems for New Construction & Upgrades to Existing Systems
UMC Hospital Las Vegas, Nevada
Upgrades to Existing Electrical Systems
Boulevard Mall Las Vegas, Nevada
Upgrades to Existing Electrical Systems
MULTI-FAMILY HOUSING
Hampstead Heath Anchorage, Alaska
Installation of Electrical Systems for New Construction of 88 Units with Clubhouse
Brittany Estates Anchorage, Alaska
Installation of Electrical Systems for New Construction
Prestige 4-Plexes Anchorage, Alaska
Installation of Electrical Systems for New Construction
Foxwood Condominiums Anchorage, Alaska
Installation of Electrical Systems for New Construction of 56 Units
Turnberry Tower Condominiums Las Vegas, Nevada
Installation of Electrical Systems for New Construction
Park Tower Condominiums Las Vegas, Nevada
Installatio n of Electrical Systems for New Construction
Eagle Electric LLC
“Building Our Future”and “Doing It Right”with effective partnerships
Electrical Contractors ▓Commercial, Industrial, Residential, Service & Maintenance ▓Licensed, Bonded & Insured
CUSTOM HOUSING
Sable Ridge Las Vegas, Nevada
Spanish Trails Las Vegas, Nevada
Southern Highlands Las Vegas, Nevada
The Enclaves Las Vegas, Nevada
Installation of Electrical Systems for New Construction
Business Information
Type of Business:Electrical Contractor
Date Business Established:1987
Federal Employer I.D. No.:92-0164963
State of Alaska Employer I.D. No.:0001358626
Dun & Bradstreet No.:602061046-1046
Alaska Business License No:255681
Alaska Contractor’s License No.:25788
Service Classification NAICS Codes
238210 -Electrical Contractors
236116 -MultifamilyHousing Construction
236210 -Industrial Building Construction
236220 -Commercial & Institutional Building Construction
541330 –Engineering Services
561210 –Facilities Operations and Support Services
811310 –Commercial & Industrial Machinery & Equipment (except Automotive & Electronic) Repair and
Maintenance)
Service
Our service team tailors preventive maintenance plans to suit specific needs and concerns. Ensuring proper
operation of equipment can help extend equipment life, resulting in fewer equipment breakdowns, reducing
emergency service calls and increasing operating efficiency.
On larger projects, we emplo y program managers to help assure that the projects are organized with a single point of
contact for our customers and our project personnel.
Selected Experience
The following projects have been selected to demonstrate Eagle Electric’s capabilities and qu alifications in
providing prime contracting, building operation, maintenance and electrical services for a variety of project types.
Chugach View Senior Housing Complex , Contract Amount -$590,689.00
Total of approved Change Orders was $250,121.67 Revised Contract Amount is
$840,811. Complete wiring to remodel complex to house seniors while occupied.
Project consisted of upgrading systems and fire alarm monitoring and emergency
systems.
Town Square Manor-90 unit, Contract Amount is $310,000. Electrical services
included wiring for 90 unit apartment complex with garages –including power, lights,
and fire alarm system.
Eagle Electric LLC
“Building Our Future”and “Doing It Right”with effective partnerships
Electrical Contractors ▓Commercial, Industrial, Residential, Service & Maintenance ▓Licensed, Bonded & Insured
Lowe’s Retail Facility, Fairbanks , Contract Amount -$1,011,669
Total of (24) Change Orders for approximately $ 150,000. The project consisted of all
electrical and systems wiring within this almost 200,000 square foot facility. The
building management systems include emergency generator, Novar lighting, automated
temperature controls, remote humidity sensors, and occupancy sensors. The General
Contractor is Roger Hickel Contracting.
Anchorage Pioneer Home Fire Alarm Replacement., Contract Amount $ 492,333
Th is State funded project consisted of providing a new code compliant fire alarm system
for the Anchorage Pioneer Home and removing the two existing systems.The Client is
the State of Alaska.
Nome Youth Facility, Contract Amount -$284,729.00
General Contractor is Hankal Construction. Scope of work included a new 600 amp
service, all new lighting, approximately 100 fixtures, design and installation of new
central lighting control.
Multi Purpose Facility,King Island Native Community Nome,Amount -$96,360
Scope of work included 3,000 sq. ft., complete new 200 amp service, and fire alarm
service. The building houses a recreation area, carving room, community conference
room and a store.
Old Federal Building –BSNCNew Headquarters .Scope of work included renovation
of the entire 3rd floor, including new panels, lights, telecommunications, and updating
existing wiring to bring it up to current code.
Anvil Mountain Correctional Facility Fire Alarm Replacement in Nome.Contract
Amount is $125,000.Owner is the State of Alaska, Department of Corrections.Project
consists of a complete reinstallation/replacement of the fire alarm system.
Eagle Electric LLC
“Building Our Future”and “Doing It Right”with effective partnerships
Electrical Contractors ▓Commercial, Industrial, Residential, Service & Maintenance ▓Licensed, Bonded & Insured
Some of Our Customers…..Selected Local Customers
Selected Nationwide Customers