TOWER St
BY OTH EF
FOOTING
CADWELD TAC-2C2C, TEE
CONNECTION, 2/0 AWG
TO 2/0 AND CU.
CL TOWER
r\AMr-r%P1r11 rl r-^'rMI^ AI
SECTION B
1:50 S-1
25mm PVC
CONDUIT
� TOWER
PE ESTAL
P7
LADDER
DOOR 1000
PRIOR TO CONCRETE POUR, FIT
STYROFOAM BLOCKS (l50x45Ox5
TO FORM A POCKET AROUND Nl
UNDERSIDE OF STEEL TEMPLATE
ACCESS TO JAM NUTS (8 LOCAT
q TOWER
FOUNDATION PLAN
1:100
(2 FOUNDATIONS REQ'D TOTAL)
w
0
H
)x252 FOUNDATION
IGE PLATE WITH
z
N
0
6
Of
r-
w
J
a
O
0
N
IFS
E.W. - EACH WAY
CL. - CLEAR
NOTE:
ALL DIMENSIONS ARE IN
MILLIMETERS UNLESS
NOTED OTHERWISE.
^n NOT WELD
OVE FLANGE
ATE
NSO PASTE
D TAPE
-35mmO HOLES. TACK
FOUNDATION FLANGE PLATE
1:50
760 PVC SCH, 40 CL TOWER
EMBEDDED DRAIN PIPE
WITH HINGED GRATE
WELD
FOUNDATION FLANGE
PLATE AND ANCHOR ROD
TACK WELD DETAIL
N.T.S.
FLOOR DRAIN CONCRETE TO BE LEVEL UNDER
ANCHOR RODS BEARING PLATE OF TOWER
(SEE DETAIL) TOWER SUPPLIED
25mm NON- BY OTHERS
SHRINK GROUT 25M at 250
PROVIDE GRATED COVER E.W.
FOR RODENT PREVENTION 20mm CHAMFER
GRADE 75 CL. ALL AROUND
o � Dn 20 soo
0 Dn 38 M14.2650
Dn 4% _ _ _ 25M at 250
600
0
L
COMPACTED 75 CL. 5-25M CONT,
FILL
CD
O
to Ar p
o oz_
cq N o0 75 CL,
rn
TILL OR LEAN CONCRETE
OR ENGINEERED FILL
(SEE OTHER DETAILS
AND NOTES)
GROUND ROD 16mm x 3000mm
= _
L _ _ _
W/ EXOTHERMIC CONNECTION
CADWELD GTC-162C, 2/0 AWG CU
TO 16mm COPPER CLAD GROUND ROD
\
1500
2/0 AWG COPPER BURIED
600mm BELOW GRADE
TOP OF GROUND RODS TO BE
MINIMUM 460mm BELOW GRADE
USE 25mm PVC CONDUIT TO BRING
COPPER GROUND CONDUCTOR
THROUGH TURBINE FOUNDATION AND
FLOOR FOR CABLE PROTECTION.
SEE DETAIL STUD CONDUITS MIN.
100mm ABOVE SLAB. SEAL
CONDUIT TO PREVENT ENTRANCE OF
WATER, DIRT CONCRETE, ETC.
1:100
BOLTED LUG CONNECTION
TO OUTER CULVERT
(2 PLACES)
2/0 AWG
STRANDED COPPER
O
O
REBAR FOUNDATION `V
SUPPORT FLANGE PLATE u/s OF
FLANGE PL.
3850 IL 5100 3850
12800 SQUARE FOOTING
SECTION
A
1:50 S-1
STUB UP 100mm TAIL NOTE: 100mm MIN.
OF 2/0 AWG CU ABOVE 1. PRIMARY AND SECONDARY CONDUITS SHALL LEAN CONC.
FUTURE PAD BE CUT OFF SO THAT END BELTS ARE MUD SLAB
APPROXIMATELY 25mm ABOVE THE
CONCRETE PAD SURFACE. INSTALL CABLE
PROTECTORS ON PRIMARY AND SECONDARY
CONDUITS TO PREVENT DRAINAGE TO
FUTURE TRANSFORMER CABLE INSULATION. TEMPORARY CAP OR
PAD BY OTHERS PLUG ALL CONDUIT DURING CONTRACTION.
2-50mmO COMMUNICATIONS
CONDUIT
2-100mmO CONDUIT
2. ALL CONDUIT SHALL BE SCHEDULE 40 PVC LEAN CONCRE
UNLESS OTHERWISE NOTED, ENGINEERED Ftt_t_ rrnu_tlr r«w v tt_t_
BASED ON CONDITION OF INSITU
3. SEAL ALL DUCTS AT TRANSFORMER WITH MATERIAL AND AS DIRECTED BY
FOAM SEALANT. CAULK BASE OF GEOTECHNICAL ENGINEER
TRANSFORMER ON INSIDE OF CABINET
(BY OTHERS). LEAN CONCRETE OR ENGINEERED FILL
UNDER TOWER FOUNDATION
(WHERE REQUIRED)
N.T.S.
PL50 SPLICE
PLATE
TYPICAL SPLICE
OF FOUNDATION
FLANGE PLATE
1:20
25M at 300 E.W.
(INSTALL AFTER FLANGE PL,
AND ANCHOR RODS ARE IN PLACE)
75 CL.
20M at 300
30M at 240
E.W.
750 ON 2 SIDES
690 ON 2 SIDES
600
75 CL.
100mm MIN. CONCRETE MUD SLAB
15MPa LEAN CONCRETE (28 DAY STRENGTH)
EXTEND 500mm BEYOND EDGE OF FOOTING
FOUNDATION DESIGN LOADS
(AS SUPPLIED BY HELIMAX ENERGY INC.)
SERVICE LOADS AT UNDERSIDE OF BASE PLATE:
P = 1190 kN VERTICAL LOAD DUE TO DEAD LOAD
V = 371 kN BASE SHEAR DUE TO WIND LOAD
M = 24202 kN-m BASE OVERTURNING MOMENT
DUE TO WIND LOAD
Mz = 1037 kN-m BASE TORSIONAL MOMENT
DUE TO WIND LOAD
M P
rV
O
LO
M
T.O. CONC.
0
LO
PO O
O
00
N
NUT AND
WASHER
HALF -HEIGHT JAM NUT
REQUIRED FOR 1 IN 10
BOLTS (16 LOCATIONS)
ANCHOR ROD NOTES:
1. 13C O,D., GRADE B-7
THREADED BARS
BY WILLIAMS.
2. WASHERS TO BE
HARDENED STEEL
(ASTM F436).
2-NUTS AND
WASHERS
ANCHOR ROD DETAIL
(160 REQUIRED IN EACH FOUNDATION)
1:20
ANCHOR ROD INSTALLATION NOTES:
1. FOUNDATION CONTRACTOR SHALL PRIME ANCHOR RODS
BETWEEN THE TOWER BEARING PLATE AND THE FOUNDATION
FLANGE PLATE WITH DENSO PASTE (PETROLEUM TAPE PRIMER)
FOLLOWED BY A DOUBLE WRAP OF DENSO LT TAPE (LOW
TEMPERATURE PETROLATUM TAPE). TAPE AND PASTE TO BE
SUPPLIED BY OWNER AND INSTALLED BY FOUNDATION CONTRACTOR.
NOTE: STOP APPLICATION OF TAPE AND PASTE WHERE
INSTALLATION OF NUTS AND WASHERS IS REQUIRED
INCLUDING LOWERING OF THE JAMB NUTS. APPLY AFTER
INSTALLATION OF NUTS AND WASHERS ARE COMPLETE.
2, STEEL TEMPLATE FOR POSITIONING OF ANCHOR RODS
IS TO BE SUPPLIED BY THE TOWER MANUFACTURER AND
INSTALLED BY THE FOUNDATION CONTRACTOR. VIBRATE
CONCRETE INTO PLACE DIRECTLY UNDER TEMPLATE,
REMOVE THE TEMPLATE AFTER CONCRETE IS PLACED.
TEMPLATE IS SIMILAR IN SIZE TO FOUNDATION FLANGE PLATE,
STEEL TEMPLATE ANCHOR ROD HOLE DIA. = 31 mmO
3. FOUNDATION CONTRACTOR IS RESPONSIBLE FOR ENSURING
THAT TEMPLATE IS LEVEL AND ACCURATELY POSITIONED
PRIOR TO ANCHOR ROD AND CONCRETE PLACEMENT.
USE HALF -HEIGHT JAM NUTS ON EVERY TENTH SET
OF BOLTS (MAX.) TO HOLD AND POSITION TEMPLATE.
4. TOLERANCE FOR ANCHOR ROD PLACEMENT AT TOP:
1.7mm HORIZ, AND 3.2mm VERT.
5. ANCHOR RODS AND NUTS SHALL BE TACK WELDED TO
UNDERSIDE OF FOUNDATION FLANGE PLATE. DO NOT
WELD ANCHORS ABOVE PLATE.
TOWER BASE ERECTION NOTES:
1. PRIOR TO TOWER ERECTION, REMOVE STYROFOAM BLOCKS
IN 8 LOCATIONS AT TOP OF PEDESTAL.
2. ERECT TOWER BASE AND LEVEL USING HALF -HEIGHT JAM NUTS.
3. GROUT UNDER TOWER BEARING PLATE,
4. LOWER HALF -HEIGHT JAM NUTS AFTER PLACING GROUT UNDER
TOWER BEARING PLATE. GROUT POCKETS.
5. TENSION RODS TO 245 kN/BOLT USING HYDRAULIC JACK.
TENSION LOAD TO BE INDEPENDENTLY TESTED (PAID BY OWNER).
6. THE TOP OF THE ROD AND NUT ABOVE THE TOWER BEARING
PLATE SHALL BE COVERED WITH DENSO PASTE.
APPLY A FINAL PLASTIC PROTECTION CAP OVER THE GREASED ROD,
TWIST CAP TO CAPTURE FLATS OF NUTS. DRIVE CAP DOWN
USING A DEAD BLOW MALLET. GREASE AND CAPS TO BE SUPPLIED
BY THE OWNER AND INSTALLED BY THE FOUNDATION CONTRACTOR.
7. CAULK AND SEAL JOINTS AT BASE PLATE AFTER RODS ARE TENSIONED.
NOTE: THIS DRAWING IS THE PROPERTY OF EASTERN
DESIGNERS & COMPANY LIMITED LOANED TO
TOWER, FOUNDATION FLANGE PLATETHE RECIPIENT WHO AGREES THAT SHALL
NOT BE GIVEN OUT, COPIED OR DUPLICATED
LICATED
,
TEMPLATE, ANCHOR RODS (INCLUDING NUTS AND FOR THE USE OF ANOTHER, BUT USED ONLY
BY THE RECIPIENT FOR THE PURPOSE TO
WASHERS) AND ANCHOR ROD PASTE AND OUTERWRAP WHICH IT REFERS.
TAPE SHALL BE SUPPLIED TO THE SITE BY OTHERS.
THIS CONTRACTOR SHALL BE RESPONSIBLE TO SUPPLY
ALL OTHER MATERIALS AND LABOR NECESSARY TO c Ol
INSTALL THESE ITEMS AS INDICATED ON THE DRAWINGS. �-- )C)
0
1
REV. DATE REVISIONS BY 0�
G
A Aug. 26/05
Issued for Review
D.L.V.
SITEWORK AND FOUNDATION NOTES
1. GENERAL - THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
REPORT ANY DISCREPANCIES TO THE ENGINEER BEFORE PROCEEDING
WITH THE WORK.
2. ALL FOUNDATION WORK SHALL BE CARRIED OUT UNDER THE DIRECTION
OF THE GEOTECHNICAL CONSULTANT.
3. EXISTING GEOTECHNICAL DATA INCLUDING GROUND SURFACE ELEVATIONS
AND TOWER LOCATIONS ARE TAKEN FROM REPORTS BY GEMTEC LIMITED.
DEWATER AS REQUIRED.
4. TOWER FOUNDATIONS TO BE PLACED ON UNDISTURBED GLACIAL TILL
MATERIAL CAPABLE OF SUPPORTING A SAFE BEARING LOAD OF 300 kPa.
5. IF SOFT OR UNSUITABLE MATERIALS ARE FOUND BELOW FOOTING
LEVEL, EXCAVATE AND REMOVE UNDESIRABLE MATERIALS AND REPLACE
WITH LEAN CONCRETE (15 MPa) OR ENGINEERED FILL AS DIRECTED BY
GEOTECHNICAL ENGINEER.
6. SOURCES OF GRANULAR BACKFILL , FIELD COMPACTION TECHNIQUES
AND DENSITIES OBTAINED, ARE SUBJECT TO THE APPROVAL OF
THE GEOTECHNICAL ENGINEER.
7. BACKFILL CONCRETE FOUNDATION USING COMPACTED SELECT BORROW.
PLACE BACKFILL OVER FOOTINGS IN 150mm LIFTS AND COMPACT TO
95% OF ASTM STANDARD PROCTOR DENSITY.
CONCRETE NOTES
1. GENERAL - THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
REPORT ANY DISCREPANCIES TO THE ENGINEER BEFORE PROCEEDING
WITH THE WORK.
2. ALL CONCRETE WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE
APPLICABLE PROVISIONS OF CSA A23.1-04 AND THE NATIONAL BUILDING
CODE OF CANADA, 1995 EDITION.
3. ALL CONCRETE MATERIALS SHALL CONFORM TO:
CEMENT CAN/CSA-A5-03, TYPE 10
AGGREGATES CSA A23.1-04
AIR ENTRAINING ASTM C260-01
CHEMICAL ADMIXTURES ASTM C494/C494m-04
REINFORCING BARS CAN/CSA-G30.18-M92 GRADE 400
MIX DESIGN CSA A23.1-04
4. CONCRETE SHALL BE PROPORTIONED IN ACCORDANCE WITH
CSA A23.1-04 TO GIVE THE FOLLOWING MIX DESIGNS:
MIX I - FOOTINGS AND PEDESTALS
STRENGTH CLASS 25 MPa
AGGREGATE SIZE 20 mm
SLUMP 80 mm
AIR 5 - 8%
WATER/CEMENT RATIO 0.55 max.
ALKALI -AGGREGATE REACTIVITY
AGGREGATES WHICH REACT WITH ALKALIES ARE TO BE USED ONLY WHEN
PREVENTIVE MEASURES ACCEPTABLE TO THE OWNER ARE APPLIED. SUCH
AGGREGATES SHALL BE NOTED WHEN THE CONCRETE MIX IS SUBMITTED FOR
REVIEW AND THE DECISION ON THEIR USE SHALL BE MADE AT THAT TIME.
5. CONCRETE MIX DESIGNS SHALL BE SUBMITTED FOR REVIEW BY THE ENGINEER
48 HOURS PRIOR TO USE. OBTAIN ENGINEER'S APPROVAL BEFORE USING
CONCRETE ADMIXTURES. USE OF CALCIUM CHLORIDE WILL NOT BE PERMITTED.
6. CONCRETE TESTING SHALL CONFORM TO CSA A23.2-04. MINIMUM TESTING
SHALL INCLUDE 3 STRENGTH TESTS FOR EVERY CONCRETE POUR. SLUMP
AND AIR TESTS TO ACCOMPANY CYLINDER TESTING. PROVIDE 24 HOURS
NOTICE PRIOR TO PLACING ANY CONCRETE. TESTING WILL BE PERFORMED
BY THE OWNER
7. CONCRETE COVER, U.N.O.
FOOTINGS 75mm
PEDESTALS 75mm U.N.O.
USE SPACERS AND CHAIRS TO ACCURATELY LOCATE AND SUPPORT
REINFORCING STEEL AND SECURE IN POSITION TO PREVENT
DISPLACEMENT DURING CONCRETE PLACEMENT.
8. REINFORCING - BILLET STEEL, GRADE 400, DEFORMED BARS TO CAN/CSA-
G30.18-M92. SUBMIT REINFORCING STEEL SHOP DRAWINGS FOR REVIEW
PRIOR TO FABRICATION. REINFORCING BAR SPLICES SHALL BE DETAILED AS
FOLLOWS:
VERTICAL BARS HORIZONTAL BARS
10M - 380 mm 10M - 490 mm
15M - 570 mm 15M - 740 mm
20M - 750 mm 20M - 980 mm
25M - 1170 mm 25M - 1530 mm
TYPICAL UNLESS NOTED OTHERWISE
9. SHOP DRAWINGS - SUBMIT 1 SET OF SEPIAS AND 2 SETS OF PRINTS OF ALL
SHOP DRAWINGS PRIOR TO FABRICATING REINFORCING STEEL. CLEARLY INDICATE
BAR SIZES, SPACING, LOCATION AND QUANTITIES OF REINFORCEMENT, CHAIRS,
SPACERS AND HANGERS WITH IDENTIFYING CODE MARKS TO PERMIT CORRECT
PLACEMENT WITHOUT REFERENCE TO STRUCTURAL DRAWINGS: TO CSA A23.3-04,
TO REINFORCING MANUAL OF STANDARD PRACTICE - 2004 BY REINFORCING
STEEL INSTITUTE OF CANADA. DETAIL PLACEMENT OF REINFORCING WHERE
SPECIAL CONDITIONS OCCUR.
10. CONCRETE FORMWORK SHALL BE CONSTRUCTED FROM PLYWOOD SHEETS
MEETING THE REQUIREMENTS OF CSA 0121-M1978. PLYWOOD SHEETS TO
BE CLEAN, SOUND, FREE FROM DEFECTS DETRIMENTAL TO THE QUALITY
OF FINISHED CONCRETE SURFACES. ARRANGE PLYWOOD SHEETS TO A
UNIFORM JOINT PATTERN. CONSTRUCT FORMWORK TO RESIST FLUID
PRESSURE FROM WET CONCRETE AND ALL OTHER CONSTRUCTION LOADINGS
WITHOUT BULGING, MOVEMENT OR DISTORTION. REUSE OF FORMWORK
SUBJECT TO THE REQUIREMENTS OF CSA A23.1-04.
11. ANCHOR RODS - SET ANCHOR RODS, INSERT PLATES, SLEEVES AND
OTHER MISCELLANEOUS ITEMS EMBEDDED IN CONCRETE ACCURATELY TO
EXACT GRADE AND LOCATION SHOWN ON PROJECT DRAWINGS OR AS
DIRECTED BY OWNER'S SITE REPRESENTATIVES. SECURE TO PREVENT
DISPLACEMENT DURING CONCRETE PLACEMENT.
12. CONCRETE FORMWORK SHALL REMAIN IN PLACE A MINIMUM OF 2 DAYS
FOLLOWING CONCRETE PLACEMENT.
13. ALL CONCRETE SHALL BE VIBRATED USING HIGH FREQUENCY VIBRATORS.
VIBRATION PRACTICES TO BE IN ACCORDANCE WITH ACI 309R-96.
14. CONCRETE CURING AND PROTECTION SHALL CONFORM TO CSA A23.1-04.
CURING SHALL BE BY CONTINUOUS WATER CURING.
COVER WITH A BURLAP TYPE MATERIAL AND KEEP WET FOR 7 DAYS OR
UNTIL BACKFILLED.
15. USE WIND BREAKS/SUN SCREENS, FOG SPRAY AS REQUIRED TO PREVENT
PREMATURE DRYING OF CONCRETE PRIOR TO FINISHING.
16. FORMED CONCRETE SURFACES SHALL BE SURFACE FINISHED AS SOON AS
PRACTICAL AND NOT LATER THAN 6 HOURS FOLLOWING FORMWORK
REMOVAL. REMOVE ALL FORM TIES, FINS AND PROJECTIONS. PATCH
TIE HOLES, INDENTATIONS AND OTHER SURFACE IRREGULARITIES WITH
SAND CEMENT PATCHING MORTAR F'c - 30 MPa. FILL AND REPAIR
HONEYCOMB AND HOLES.
17. TOWER BEARING PLATE TO BE GROUTED USING 50 MPa NON-SHINK GROUT.
GROUT SHALL BE OF POURABLE CONSISTENCY. DRY PACK OF GROUT IS
NOT PERMITTED.
STEEL NOTES
1. ALL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF CAN/CSA-
S16-01 AND TO THE NATIONAL BUILDING CODE OF CANADA, 1995 EDITION.
2. STRUCTURAL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF
CAN/CSA-G40.21-04.
3. MATERIAL PROPERTIES:
STEEL PLATE............ CAN/CSA-G40.21-04-300W
ANCHOR RODS......... ASTM A-193 GRADE B-7 THREADED BARS BY WILLIAMS
FORM HARDWARE AND ROCKBOLT (CANADA) INC. OR
EQUIVALENT
4. ANCHOR RODS SHALL HAVE MINIMUM AVERAGE CHARPY IMPACT ENERGY OF
40J AT -7'C. TEST RESULTS SHALL BE BASED ON THE AVERAGE OF THREE
SPECIMENS WITH NO MORE THAN ONE VALUE BELOW THE MINIMUM VALUE
AND IN NO CASE LESS THAN TWO-THIRDS OF THE MINIMUM AVERAGE VALUE.
5. ANCHOR ROD HOLES IN FOUNDATION FLANGE PLATE SHALL BE DRILLED.
6. SHOP DRAWINGS - SUBMIT 1 SET OF SEPIAS AND 2 SETS OF PRINTS OF ALL
SHOP DRAWINGS FOR REVIEW BY ENGINEER PRIOR TO FABRICATING.
7. PROVIDE MILL TEST CERTIFICATES FOR ANCHOR RODS.
EASTERN DESIGNERS & COMPANY LIMITED
Engineering Consultonts
FREDERICTON, N.B., CANADA
Ph. (506)452-8480 Fax. (506)452-1510
WIND TURBINE GENERATOR FOUNDATION
VECTOR WIND ENERGY INC., SPRINGHILL, N.S.
FOUNDATION DETAILS
SCALE AS NOTED DATE DRAWING No.
DRAWN K.C.R.L. AUG. 2005
DESIGNED D.L.V. AUG. 2005 s-'I
CHECKED B.J.B. AUG. 2005
REV.