HomeMy WebLinkAboutPILOTP~8 Renewable Energy Fund
RFA AEA 09-004 Application Cost Worksheet revised 9/26/08 Page 1
Application Cost Worksheet – Lake & Pen Regional Wind
Recon/Feasibility Study - Pilot Point Wind Study
Please note that some fields might not be applicable for all technologies or all project
phases. Level of information detail varies according to phase requirements.
1. Renewable Energy Source
The Applicant should demonstrate that the renewable energy resource is available on a
sustainable basis.
Annual average resource availability. Wind class 5
Unit depends on project type (e.g. windspeed, hydropower output, biomasss fuel)
2. Existing Energy Generation
a) Basic configuration (if system is part of the Railbelt1 grid, leave this section blank)
i. Number of generators/boilers/other
ii. Rated capacity of generators/boilers/other
iii. Generator/boilers/other type
iv. Age of generators/boilers/other
v. Efficiency of generators/boilers/other
b) Annual O&M cost (if system is part of the Railbelt grid, leave this section blank)
i. Annual O&M cost for labor
ii. Annual O&M cost for non-labor
c) Annual electricity production and fuel usage (fill in as applicable) (if system is part of the
Railbelt grid, leave this section blank)
i. Electricity [kWh] 400,000 kWh/year
ii. Fuel usage
Diesel [gal] 39,000 gallons
Other
iii. Peak Load
iv. Average Load
v. Minimum Load
vi. Efficiency 0.0985 gallons per kWh
vii. Future trends 0.0895 gallons per kWh
d) Annual heating fuel usage (fill in as applicable)
i. Diesel [gal or MMBtu]
1 The Railbelt grid connects all customers of Chugach Electric Association, Homer Electric Association, Golden
Valley Electric Association, the City of Seward Electric Department, Matanuska Electric Association and Anchorage
Municipal Light and Power.
Renewable Energy Fund
RFA AEA 09-004 Application Cost Worksheet revised 9/26/08 Page 2
ii. Electricity [kWh]
iii. Propane [gal or MMBtu]
iv. Coal [tons or MMBtu]
v. Wood [cords, green tons, dry tons]
vi. Other
3. Proposed System Design
a) Installed capacity 1 X 65 kW
b) Annual renewable electricity generation
i. Diesel [gal or MMBtu]
ii. Electricity [kWh] 160,000 kWhs
iii. Propane [gal or MMBtu]
iv. Coal [tons or MMBtu]
v. Wood [cords, green tons, dry tons]
vi. Other
4. Project Cost
a) Total capital cost of new system $520,000
b) Development cost $38,000 per community as part of region wide
initiative
c) Annual O&M cost of new system $10,400
d) Annual fuel cost na
5. Project Benefits
a) Amount of fuel displaced for
i. Electricity 14,324 gallons
ii. Heat Dump load heating potential to be developed in recon/feasibilit y study
iii. Transportation
b) Price of displaced fuel Long run price of diesel fuel in Pilot Point is estimated
at $5.75 per gallon
c) Other economic benefits
d) Amount of Alaska public benefits
6. Power Purchase/Sales Price
Renewable Energy Fund
RFA AEA 09-004 Application Cost Worksheet revised 9/26/08 Page 3
a) Price for power purchase/sale
7. Project Analysis
a) Basic Economic Analysis
Project benefit/cost ratio 1.2
Payback 7 years
PLEASE SEE ATTACHED SPREADSHEETS FROM THE
LAKE & PENINSULA BOROUGH ENERGY PLAN SCREENING STUDY
FOR ADDITIONAL DETAIL ON THE ECONOMIC ANALYSIS OF WIND OPPORTUNITIES IN
Port Heiden