Loading...
HomeMy WebLinkAboutEnerflex Overview BrochureA Single Source You know us as Enerflex. Now, how well do you really know us? Look closely at Enerflex and you’ll discover we deliver much more than natural gas compression and construction services. Sure, we still make compressors in a hundred different horsepower configurations and process packages that ensure production never stops. That’s the nuts and bolts of our business. But there’s a lot more. In 28 years, we’ve become the go-to source for oil and gas producers seeking to optimize throughput from oil and gas fields around the world. From multi-million dollar gas processing facilities in Pakistan to combined heat and power generators in the Netherlands. From the construction of a liquefied natural gas processing facility in Western Australia to worldwide turnkey solutions. In the Americas, Australasia, Europe, the Middle East and beyond. The fact is – Enerflex is an international service company delivering products and services to all corners of the globe, focusing on processing and moving your energy between the wellhead and pipeline. We leverage our products and services experience to deliver integrated solutions from turnkey delivery and life-cycle management of your process and compression assets, to incremental gas and oil recovery in older reservoirs. Look closely at Enerflex. Now, how well do you really know us? • Integrated Turnkey Solutions • Performance Drivers • Customer Service • Innovation • Expertise • Knowledge Base • Worldwide Solutions • Premium Provider • Over 2,700 Employees ENERFLEX 1 Production and Processing Gas Processing• Oil Processing• Process Equipment• Inlet Separation/Filtration• Amine Sweetening• TEG Dehydration• Molecular Sieve• HC Liquids Fractionation• LPG Extraction• Specialty Equipment• Engineered Flare Systems• Compression and Power Reciprocating Compression• Rotary Screw Compression• Compressor Optimization• Power Generation• Combined Heat and Power Units• Standard or Custom-Designed • Onshore or Offshore• PRODUCTS Enerflex combines proven processing, compression and power generation systems with over 28 years’ experience operating in hydrocarbon basins throughout the world to engineer and construct the facilities you need. From the simplest gas dehydration units and line heaters, to metering, central processing and deep-cut ethane extraction facilities. Integrated solutions from Enerflex deliver all of the equipment you need to bring hydrocarbons from the wellhead up to pipeline specifications. Enerflex’s process and compression product lines are renowned for their reliability and operating efficiency, while seamless coordination among our business units dramatically shortens procurement timelines. Equipment is half our story. The other half is Enerflex’s in-house expertise. We’ll help you select the right gas processing and compression components and engineer the plant to maximize the value of your hydrocarbon stream. That’s the Enerflex advantage. Together, integrated products and solutions from wellhead to pipeline. ENERFLEX 3 Production Process Equipment Rentals• Compression Equipment Rentals• Remanufactured Compression• Portable Compression• Compression Optimization• Flue Gas Compression Units• Mechanical Preventative Maintenance • and Repair Field and Shop Major • Overhaul Services Compressor Installation • and Commissioning Performance Optimization• Spare Parts, Including Waukesha • and Caterpillar Engines Exchange Products for Screw • and Reciprocating Compressors • Exclusive Waukesha Distributor in Canada, Australia, Spain, Portugal, the Netherlands, Germany, Indonesia and Alaska SERvICES Electrical Electrical Maintenance and Construction • Instrumentation Maintenance • and Construction Control Systems/SCADA • System Automation • Compressor Controls • Complete Calibration Facility• Construction Gas Processing Facilities• Gas Compression Facilities• Coal Bed Methane Facilities• LNG Plants• Power Stations• Pipeline Facilities• Enerflex will help you move more hydrocarbons, more cost-effectively throughout the life cycle of your well. It’s really that simple. The next time you’re planning an exploration or development well, invite us to the table to explore the options for facilities. We’ll assist with early evaluation and assessment and advise how you can save on vital cash outlays by renting equipment in the early production period. Once the well’s baseline production information is available, we’ll help configure the permanent processing facility. And we’ll manage the construction process to ensure on-time and on-budget delivery. As the field’s production profile changes, we can scale facilities and equipment up or down, providing the right tools at the right time. Better still, you can trust us to continually find ways to maximize both equipment uptime and the value from your hydrocarbon stream. variable Cost Production (vCP) VCP gives you access to Enerflex’s rental fleet, operational expertise and financial flexibility. VCP agreements can be as simple as a rental service with all-inclusive maintenance, or all the way to turnkey installations with ongoing operation, maintenance and optimization by Enerflex. With any solution, you control your production. Together, the right tools at the right time. ENERFLEX 5 INTEGRATED TURNKEy SOLUTIONS Concept to Commissioning full-cycle solutions – from a true single source. Enerflex has the resources and experience to execute projects anywhere in the world encompassing all phases of engineering, procurement, manufacture, construction and commissioning. Starting at the well planning or testing phase, Enerflex has a proven ability to engineer your gas processing and compression facility for its specific operating environment. We follow through with a product line starting from the wellhead and delivering to the pipeline or beyond, providing you with seamless compatibility, zero interface risk and the fastest timeline from design to commissioning. In today’s fast-paced, continuously evolving oil and gas industry, where project life-cycles get shorter and shorter, Enerflex breaks from the tradition of the typical EPC approach, getting energy to the market when it matters – as quickly as possible. Integrated Turnkey Solutions – breaking from tradition. Customers with Enerflex Customers without Enerflex Typical natural gas processing facilities require approximately 18-24 months to plan, design, procure, construct and commission. Enerflex can reduce the schedule by four to six months, since the majority of the processes and components are located in-house. Our pre-fabricated, modularized products also allow for an accelerated construction and commissioning phase. That’s four to six months of additional cash flow and more rapid payout of the facility’s cost. Design + Front-End Engineering Detailed Engineering Construction Installation Commission + Start-upProcurement and Fabrication Design + Front-End Engineering Procurement and FabricationDetailed Engineering Commission + Start-up Construction Installation 5 – 8 mos.8 – 10 mos. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30Months 12 mos.6 – 9 mos. ENHANCING PRODUCTION AND PROFITABILIT y Enerflex has a proven ability to develop solutions or modify existing equipment to satisfy your changing requirements. We’re even applying technology originally developed for the energy production and processing industry in new applications. For example, Enerflex’s Combined Heat and Power units use the byproducts of power generation to help minimize production costs for flower growers in the Netherlands. At the same time, we’re tackling old challenges in new ways to enhance your production and profitability. Exhaust Gas Compression units were developed to optimize oil and natural gas reserves recovery using compressor engine exhaust instead of more expensive inert gas supplies to increase reservoir pressure. Enerflex also created an early production model to bring your production on-stream using a temporary facility, while your permanent facility is under construction. Delivering your production to market faster allows you to take maximum advantage of today’s high commodity prices. Enerflex’s insight and experience driving product innovation. Bringing insight and experience together. ENERFLEX 7 Americas UÊ"ÛiÀÊ{xÊLÀ>˜V…ià ÊÊÊ>˜`Êvˆi`ʜvvˆVià Middle East/ North Africa UÊÓʏœV>̈œ˜Ã Europe UÊÎʏœV>̈œ˜Ã Australasia UÊÇʏœV>̈œ˜Ã A global supplier of energy processing systems. Enerflex Office Locations Algeria Angola Argentina Australia Azerbaijan Bahrain Bangladesh Barbados Belgium Bolivia Brazil Brunei Cameroon Canada Chile China Colombia Congo, Republic of Croatia Denmark Ecuador Egypt France Gabon Germany Greece Guatemala Hungary India Indonesia Italy Kazakhstan Kuwait Malaysia Mexico Netherlands New Zealand Nigeria Norway Oman Pakistan Papua New Guinea Peru Poland Qatar Russia Saudi Arabia Senegal Singapore Slovakia South Korea Spain Sudan Switzerland Syria Taiwan Tanzania Thailand Trinidad & Tobago Tunisia Turkmenistan Ukraine United Arab Emirates United Kingdom United States Venezuela Vietnam Yemen Global locations of Enerflex-supplied equipment and services. Americas UÊ"ÛiÀÊ{xÊLÀ>˜V…ià ÊÊÊ>˜`Êvˆi`ʜvvˆViÃMiddle East/ North Africa UÊÓʏœV>̈œ˜Ã Europe UÊÎʏœV>̈œ˜Ã Australasia UÊÇʏœV>̈œ˜Ã Enerflex value proposition. Our strength is in our fully integrated products and services delivery from concept-to-commissioning of engineered turnkey systems for natural gas production and oil processing facilities. Now, we’d like to know you better. Our 2,700 people worldwide are committed to helping bring energy resources on-line quickly, efficiently and cost-effectively in every major producing basin in the world. Global locations of Enerflex-supplied equipment and services. Call Enerflex to discover how the right combination of equipment and experience operating in basins throughout the world can capture more value from your assets. www.enerflex.com A Single Source Rev. 01, 05/08 Enerflex Systems Ltd. 4700 47 Street SE Calgary, Alberta, Canada T2B 3R1 Tel: 1+1.403.236.6800 Fax: 1+1.403.279.0367 Email: info@enerflex.com Web: www.enerflex.com