HomeMy WebLinkAboutQF08-542-000(Pioneer)Form Approved
OMB Control No. 1902-0075
Expires 7/31/2009
FERC Form No. 556
18 C.F.R. § 131.80
CERTIFICATION OF QUALIFYING FACILITY STATUS FOR AN EXISTING OR A
PROPOSED SMALL POWER PRODUCTION OR COGENERATION FACILITY
INFORMATION ABOUT COMPLIANCE
Compliance with the information collection requirements established by the FERC Form No. 556 is
required to obtain and maintain status as a qualifying facility. See 18 C.F.R. § 131.80 and Part 292.
An agency may not conduct or sponsor, and a person is not required to respond to, a collection of
information unless it displays a currently valid OMB control number.
SUBMITTING COMMENTS ON PUBLIC REPORTING BURDEN
The estimated burden for completing FERC Form No. 556, including gathering and reporting
information, is 4 hours for self-certifications and 38 hours for applications for Commission
certification. Send comments regarding this burden estimate or any aspect of this collection of
information, including suggestions for reducing this burden, to the following: Michael Miller, Office
of the Executive Director (ED-34), Federal Energy Regulatory Commission, 888 First Street NE.,
Washington, DC 20426; and Desk Officer for FERC, Office of Information and Regulatory Affairs,
Office of Management and Budget, Washington, DC 20503 (oira_submission@omb.eop.gov).
Include the Control No. 1902-0075 in any correspondence.
GENERAL INSTRUCTIONS
Complete this form by replacing bold text below with responses to each item, as required.
PART A: GENERAL INFORMATION TO BE SUBMITTED BY ALL APPLICANTS
1a. Full name of applicant: [Note: Applicant is the legal entity submitting this form, not the
individual employee making the filing. Generally, the Applicant will be a company, corporation or
organization, unless the facility is owned directly by an individual or individuals.]
Alpine Energy, LLC
Applicant and owner of Facility to be known as: “Pioneer Energy No. 4”
Docket Number assigned to the immediately preceding submittal filed with the
Commission in connection with the instant facility, if any:
Docket Number QF 08-
FERC Form No. 556 Page 2 of 10
Purpose of instant filing (self-certification or self-recertification [18 C.F.R. §
292.207(a)(1)], or application for Commission certification or recertification [18 C.F.R.
§§ 292.207(b) and (d)(2)]):
Self-certification
1b. Full address of applicant:
Alpine Energy, LLC
PO Box 436
Palmer, Alaska 99645
1c. Indicate the owner(s) of the facility (including the percentage of ownership held by
any electric utility or electric utility holding company, or by any persons owned by
either) and the operator of the facility. Additionally, state whether or not any of the non-
electric utility owners or their upstream owners are engaged in the generation or sale of
electric power, or have any ownership or operating interest in any electric facilities other
than qualifying facilities. In order to facilitate review of the application, the applicant
may also provide an ownership chart identifying the upstream ownership of the facility.
Such chart should indicate ownership percentages where appropriate.
Alpine Energy, LLC will own 100% of the Facility.
Alpine Energy, LLC will be the operator of the Facility.
Alpine Energy, LLC is not engaged in the generation or sale of electric power,
nor has any ownership or operating interests in any electric facility other
than qualifying facilities.
1d. Signature of authorized individual evidencing accuracy and authenticity of
information provided by applicant: [Note: A signature on a filing shall constitute a certificate that
(1) the signer has read the filing and knows its contents; (2) the contents are true as stated, to the best
knowledge and belief of the signer; and (3) the signer possesses full power and authority to sign the filing.
A person submitting a self-certification electronically via eFiling may use typed characters representing
their name to show that the person has signed the document. See 18 C.F.R. § 385.2005.]
Austin R Hobbs
Member-Manager, Alpine Energy, LLC
Signature of authorized individual evidencing accuracy of information
provided by herein by applicant.
FERC Form No. 556 Page 3 of 10
2. Person to whom communications regarding the filed information may be addressed:
Name: Austin R. Hobbs
Title: Member-Manager
Telephone number: (907) 746-3581
Mobile number: (907) 229-4941
Mailing address: Alpine Energy, LLC
PO Box 436
Palmer, Alaska 99645
3a. Location of facility to be certified:
State: Alaska
County: Matanuska Borough
City or town: Palmer
Street address (if known): Pioneer Energy No. 4
East Rebarchek Ave
Palmer, Alaska 99645
3b. Indicate the electric utilities that are contemplated to transact with the qualifying
facility (if known) and describe the services those electric utilities are expected to
provide:
Electric Utilities Services Expected
Matanuska Electric Association, Inc. Buy capacity & energy from QF
163 East Industrial Way Sell capacity & energy to QF
Palmer, Alaska 99645 Interconnection with QF
Transmission other utilities
Chugach Electric Association, Inc. Buy capacity & energy from QF
5601 Minnesota Drive Sell capacity & energy to QF
Anchorage, Alaska 99519-7494
FERC Form No. 556 Page 4 of 10
Indicate utilities interconnecting with the facility and/or providing wheeling service [18
C.F.R. §§ 292.303(c) and (d)]:
Matanuska Electric Association, Inc (“MEA”)
Indicate utilities purchasing the useful electric power output [18 C.F.R. §§ 292.101(b)(2),
292.202(g) and 292.303(a)]:
Matanuska Electric Association, Inc (“MEA”)
Chugach Electric Association, Inc. (“Chugach”)
Indicate utilities providing supplementary power, backup power, maintenance power,
and/or interruptible power service [18 C.F.R. §§ 292.101(b)(3), (b)(8), 292.303(b) and
292.305(b)]:
Matanuska Electric Association, Inc (“MEA”)
Chugach Electric Association, Inc. (“Chugach”)
4a. Describe the principal components of the facility including boilers, prime movers and
electric generators, and explain their operation. Include transmission lines, transformers
and switchyard equipment, if included as part of the facility.
5.00 MWe cogeneration facility consisting of two (2) Waukesha APG-3000
generator sets, heat recovery equipment, one primary step-up transformer
and substation, transmission lines, switchyard equipment and all required for
interconnection with the utility.
4b. Indicate the maximum gross and maximum net electric power production capacity of
the facility at the point(s) of delivery and show the derivation. [Note: Maximum gross output
is the maximum amount of power that the facility is able to produce, measured at the terminals of the
generator(s). Maximum net output is maximum gross output minus (1) any auxiliary load for devices that
are necessary and integral to the power production process (fans, pumps, etc.), and (2) any losses incurred
from the generator(s) to the point of delivery. If any electric power is consumed at the location of the QF
(or thermal host) for purposes not related to the power production process, such power should not be
subtracted from gross output for purposes of reporting maximum net output here.]
Maximum Gross Electric Power Production Capacity: 5.26 MW
Maximum Net Electric Power Production Capacity: 5.00 MW
FERC Form No. 556 Page 5 of 10
Derivation (assumptions about losses, auxiliary load or lack thereof, and calculation of
gross and net output):
Gross output of 5.26 MW reduced by .26 MW for auxiliary loads to deliver a
net output of about 5.00 MW
4c. Indicate the actual or expected installation and operation dates of the facility, or the
actual or expected date of completion of the reported modification to the facility:
Expected installation date: September 1, 2009
Expected operation dates: September 1, 2009 thru October 1, 2039
4d. Describe the primary energy input (e.g., hydro, coal, oil [18 C.F.R. § 292.202(l)],
natural gas [18 C.F.R. § 292.202(k)], solar, geothermal, wind, waste, biomass [18 C.F.R.
§ 292.202(a)], or other). For a waste energy input that does not fall within one of the
categories on the Commission's list of previously approved wastes, demonstrate that such
energy input has little or no current commercial value and that it exists in the absence of
the qualifying facility industry [18 C.F.R § 292.202(b)].
Natural Gas
5. Provide the average annual hourly energy input in terms of Btu for the following fossil
fuel energy inputs, and provide the related percentage of the total average annual hourly
energy input to the facility [18 C.F.R § 292.202(j)]. For any oil or natural gas fuel, use
lower heating value [18 C.F.R § 292.202(m)]:
Natural gas: 45.00 mmbtu/hr (LHV)
Oil: N/A
Coal: N/A
6. Discuss any particular characteristic of the facility which the cogenerator or small
power producer believes might bear on its qualifying status.
None
FERC Form No. 556 Page 6 of 10
PART C: DESCRIPTION OF THE COGENERATION FACILITY
Items 9 through 15 only need to be answered by applicants seeking certification as a cogeneration
facility. Applicants for certification as a small power production facility may delete Items 9 through
15 from their application, or enter “N/A” at each item.
9. Describe the cogeneration system [18 C.F.R §§ 292.202(c) and 292.203(b)], and state
whether the facility is a topping-cycle [18 C.F.R § 292.202(d)] or bottoming-cycle [18
C.F.R § 292.202(e)] cogeneration facility.
Pioneer Energy No. 4
A topping-cycle cogeneration facility.
Under normal operation (annualized average basis), the internal combustion
gas engines and heat recovery equipment will be operated in a base-load
manner requiring approximately 45.00 mmbtu/hr of fuel (natural gas @
LHV) input to produce a net sellable electrical output of 5.00 MWe and 15
mmbtu/hr of useable thermal energy.
Heat captured from the engines exhaust and jacket water systems (200º F)
will be used to drive a district energy system (average of about 12 mmbtu/hr)
and heat captured from the engines low-temperature cooling system (113º F)
will used to heat nearby greenhouses and like (average of about 3 mmbtu/hr).
10. To demonstrate the sequentiality of the cogeneration process [18 C.F.R § 292.202(s)]
and to support compliance with other requirements such as the operating and efficiency
standards (Item 11 below), provide a mass and heat balance (cycle) diagram depicting
average annual hourly operating conditions. Also, provide:
Using lower heating value [18 C.F.R § 292.202(m)], all fuel flow inputs in Btu/hr.,
separately indicating fossil fuel inputs for any supplementary firing in Btu/hr. [18 C.F.R §
292.202(f)]:
See Attachment A, Mass and Heat Balance Diagram with associated Working
Fluid Flow Conditions (thermal properties)
Average net electric output (kW or MW) [18 C.F.R § 292.202(g)]:
5.00 MW
Average net mechanical output in horsepower [18 C.F.R § 292.202(g)]:
N/A
FERC Form No. 556 Page 7 of 10
Number of hours of operation used to determine the average annual hourly facility inputs
and outputs:
8,200 hours
Working fluid (e.g., steam) flow conditions at input and output of prime mover(s) and at
delivery to and return from each useful thermal application, including flow rates
(lbs./hr.), temperature (deg. F), pressure (psia), and enthalpy (Btu/lb.):
See Attachment A, Mass and Heat Balance Diagram and associated Working
Fluid Flow Conditions (thermal properties)
11. Compute the operating value [applicable to a topping-cycle facility under 18 C.F.R §
292.205(a)(1)] and the efficiency value [18 C.F.R §§ 292.205(a)(2) and (b)], based on the
information provided in and corresponding to item 10, as follows:
Pt = Average annual hourly useful thermal energy output
Pe = Average annual hourly electrical output
Pm = Average annual hourly mechanical output
Pi = Average annual hourly energy input (natural gas or oil)
Ps = Average annual hourly energy input for supplementary firing (natural gas or oil)
Operating standard = 5% or more
Operating value = Pt / ( Pt + Pe + Pm )
15 / ( 15 + 17.07 + 0 ) = 46.78 %
Also Attachment B, Computation of Operating and Efficiency Values
Efficiency standard applicable to natural gas and oil fuel used in a topping-cycle facility:
= 45% or more when operating value is less than 15%, or 42.5% or more when operating
value is equal to or greater than 15%.
Efficiency value = ( Pe + Pm + 0.5Pt ) / (Pi + Ps)
( 17.07 + 0 + 7.5 ) / ( 45 + 0 ) = 54.59 %
Also Attachment B, Computation of Operating and Efficiency Values
FERC Form No. 556 Page 8 of 10
Efficiency standard applicable to natural gas and oil fuel used for supplementary firing
component of a bottoming-cycle facility:
= 45% or more
Efficiency value = ( Pe + Pm ) / Ps
N/A
FOR TOPPING-CYCLE COGENERATION FACILITIES
Items 12 and 13 only need to be answered by applicants seeking certification as a topping-cycle
cogeneration facility. Applicants for certification as a small power production facility or bottoming-
cycle cogeneration facility may delete Items 12 and 13 from their application, or enter “N/A” at each
item.
12. Identify the entity (i.e., thermal host) which will purchase the useful thermal energy
output from the facility [18 C.F.R § 292.202(h)]. Indicate whether the entity uses such
output for the purpose of space and water heating, space cooling, and/or process use.
Thermal Hosts Uses Est Average Amt
(mmbtu/hr)
District Energy Customers
(Exhaust Heat & Jacket Water)
1. Alaska State Fair Space Heating 2.00
2. P&M Gardens Space Heating 1.00
3. Palmer Industrial Park Space Heating 4.00
4. Palmer Business Park Space Heating 2.00
5. Palmer Commercial Center Space Heating 2.00
6. Other Commercial Customers Space Heating 1.00
Subtotal Dist Energy Sales 12.00
Waste-Heat Customers
(Low-Temp Cooling)
7. Alaska State Fair (Greenhouses) Space Heating .50
8. P&M Gardens (Greenhouses) Space Heating 2.00
9. Other Greenhouses Space Heating .50
Subtotal Waste-Heat Sales 3.00
Total Estimated Average Thermal Load 15.00
FERC Form No. 556 Page 9 of 10
13. In connection with the requirement that the thermal energy output be useful [18 C.F.R
§ 292.202(h)]:
For process uses by commercial or industrial host(s), describe each process (or
group of similar processes using the same quality of steam) and provide the
average annual hourly thermal energy made available to the process, less process
return. For a complex system, where the primary steam header at the host-side is
divided into various sub-uses, each having different pressure and temperature
characteristics, describe the processes associated with each sub-use and provide the
average annual hourly thermal energy delivered to each sub-use, less process return
from such sub-use. Provide a diagram showing the main steam header and the sub-
uses with other relevant information such as the average header pressure (psia), the
temperature (deg.F), the enthalpy (Btu/lb.), and the flow (lb./hr.), both in and out of
each sub-use. For space and water heating, describe the type of heating involved
(e.g., office space heating, domestic water heating) and provide the average annual
hourly thermal energy delivered and used for such purpose. For space cooling,
describe the type of cooling involved (e.g., office space cooling) and provide the
average annual hourly thermal energy used by the chiller.
As noted, thermal energy from the Facility will be used for space heating and
heating of nearby greenhouses.
See Attachment A, Mass and Heat Balance Diagram and associated Working
Fluid Flow Conditions required under Item 10 and Attachment B, the
Computation of Operating and Efficiency Values required under Item 11.
FOR NEW COGENERATION FACILITIES
Response to Item 15 is only required for certain applicants for qualified cogeneration facility status,
as described below. Applicants for small power production facilities or for cogeneration facilities not
meeting the criteria outlined below may delete Item 15 from their application, or enter “N/A.” In
addition, per 18 C.F.R. § 292.205(d)(4) all cogeneration facilities 5 MW and smaller are presumed to
comply with the requirements of 18 C.F.R. § 292.205(d)(1) and (d)(2), and therefore need not
respond to Item 15. For those applicants required to respond to Item 15, see 18 C.F.R. § 292.205(d)
and Order No. 671 for more information on making the demonstrations required in Item 15.
15. For any cogeneration facility that had not filed a notice of self -certification or an
application for Commission certification under 18 C.F.R. § 292.207 prior to February 2,
2006, also show:
FERC Form No. 556 Page 10 of 10
(i) The thermal energy output of the cogeneration facility is used in a productive and
beneficial manner [18 C.F.R §§ 292.205(d)(1), (d)(4) and (d)(5)]; and
The thermal energy output from this cogeneration facility will be exclusively for
space heating purposes, a presumptively useful thermal output, and for the space
and water heating for nearby greenhouses.
(ii) The electrical, thermal, chemical and mechanical output of the cogeneration facility is
used fundamentally for industrial, commercial, residential or institutional purposes and is
not intended fundamentally for sale to an electric utility, taking into account
technological, efficiency, economic, and variable thermal energy requirements, as well as
state laws applicable to sales of electric energy from a qualifying facility to its host
facility [18 C.F.R §§ 292.205(d)(2), (d)(3) and (d)(4)].
Pioneer Energy No. 4
292.205(d)(4) For purposes of paragraph (d)(1) and (d)(2) of this section, a new
cogeneration facility of 5 MW or smaller will be presumed to satisfy requirements of
those paragraphs.