HomeMy WebLinkAboutSusitna Hydro 1980 to 1981 Geotechnical report vol 2-' DATE DUE mco,Inc.38 293De- SET J.D.N'o.-- COpy NO.---::.- ,.., I - -,-", - ,- - ~ ! - SUSITNA HYDROELECTRIC PROJECT 1980 -81 GEOTECHNICAL REPORT VOLUME 2 APPENDIX A-F FINAL DRAFT Prepared by: •Alaska Resources Library &InformatIon ServIces Anchorage.Alaska -'-----__ALASKA POWER AUTHORITY __----' - VOLUME 2 APPENDIX A-SELECTED BIBLIOGRAPHY OF PREVIOUS INVESTIGATIONS B-WATANA DIAMOND CORE DRILLING LOGS C-DEVIL CANYON DIAMOND CORE DRILLING LOGS D-WATANA WATER PRESSURE TESTING DETAILS E-DEVIL CANYON WATER PRESSURE TESTING DETAILS F-WATANA BORROW SITE INVESTIGATION F.l -BORROW SITE D F.2 -BORROW SITE E F.3 -BORROW SITE H F.4 -BORROW SITES I &J ARLIS Alaska Resources Library &Information ServIces Anchorage.Alaska !""'" I/. APPENDIX A SELECTED BIBLIOGRAPHY OF PREVIOUS INVESTIGATIONS r"'I I I r- I -! JI"~ r SELECTED BIBLIOGRAPHY OF PREV IOUS INVESTIGATIONS Acres American Incorporated,SusitnaHydroelectric Project,Feasibility Report,1982. American Geoloqical Institute,Glossary of Geology,Kingsport Press, Tennessee,1973. ASCE,Rock Engineering for Foundations and Slopes,Vol.1 and 2, August,1976. ASCE,Symposium on Underground Rock Chambers,Phoenix,Arizona,Janu- ary,1971. Anderson,R.E.,"Preliminary Geochemistry and Geology.Little Falls Creek Area,Talkeetna Mountain Quadrangle",Alaska Division of Geological and Geophysical Surveys.Geochemical Report 19,1969. Anderson,R.E.."Geology and Geochemistry,Diana Lakes Area,Western Talkeetna Mountains".Alaska Division of Geological and Geophysi- cal Surveys,Report 34,1969. Anonymous,"Regional Geology of the Susitna-MacLaren River Area"Alaska Division of Geological and Geophysical Surveys,Annual Report,1973 Beikman,H.M.,"Preliminary Geologic Map of the Southeast Quadrant of Alaska",U.S.Geological Survey,Miscellaneous Field Studies Map l"IP-612,1974. Beikman,H.M.,Holloway,D.O.,and r~acKerett,E.M.,Jr.,"Generalized Geologic Map of the Eastern Part of Southern Alaska",U.S. Geological Survey.Open File Map 77-169-B,1977. Beikman,H.M.,"Preliminary Geologic Map of Alaska",U.S.Geological Survey,1978. Berg,H.C.,Jones.D.L.,and Richter,D.H.,"Gravina -Nutzotin Belt- Tectonic Significance of an Upper Mesozoic Sedimentary and Volcan- ic Sequence in Southern and Southeastern Alaska",U.S.Geological Survey.Professional Paper 800-0,1972. Bilello,M.A.,"A Winter Environmental Data Survey of the Drainage of the Upper Susitna River.Alaska",CRREL Internal Report 332 (unpublished),1975. Billings,M.P.,Structural Geology.Prentice-Hall,Inc.,New Jersey, pp.108-114,1962.- BIBLIOGRAPHY (Continued) Bl eifuss,D.J.,"Theory for the Design of Underground Pressure Con- duits",Power Division,ASCE,Volume 81,July,1955. Capps,S.R.,"The Southern Alaska Range",U.S.Geological Survey, Bulletin 862,1935. Capps,S.R.,"Geology of the Alaska Railroad Region",U.S.Geological Survey,Bulletin 907,1940. Chapin,To,"The Nelchina-Susitna Region,Alaska",U.S.Geological Sur- vey,Bulletin 668,1918. Clark,A.L.,Clark,S.H.and Hawley,C.C.,"Significance of Upper Pale- ozoic Oceanic Crust in the Upper Chulitna District,Westcentral Alaska Range",U.S.Geological Survey,Professional Paper 800-C, 1972. Cobb,LH.,"Metallic Mineral Resources Map of the Talkeetna Mountains Quadrange,Alaska",U.S.Geological Survey,Miscellaneous Field Studies Map MF-370,1972. Collins,S.G.and Field,W.O.,"Glaciers of the Talkeetna Mountains, Alaska",Mountain Glaciers of the Northern Hemisphere,Vol.2: Alaska and Aqjacent Canada,North Atlantic Islands,CRREL Reports, 1975. Cording,LJ.,Matthews,A.A.,and Peck,R.B.,"Design Criteria for Permanent Structural Linings for Station Excavations in Rock, Washi ngton Metropolitan Area Transit Authority",prepared for DeLeuw,Cather and Co.,July,1976. Coulter,H.W.,Hopkins,D.M.,Karlstrom,T.N.V.,Pewe,T.L., Wahrhaftig,C.,and Williams,J.R.,"Extent of Glaciations in Alaska",U.S.Geological Survey,Miscellaneous Geological Investi- gation Map 1-415,1965. Csejtey,B.,Jr.,"Reconnaissance Geologic Investigations in the Tal- keetna Mountains,Alaska",U.S.Geological Survey,Open File Report 74-147,1974. Csejtey,B.,Jr.,"Tectonic Implications of a Late Paleozoic Volcanic Arc in the Talkeetna Mountains,Southcentral Alaska",Geology, Volume 4,No.1,1976. Csejtey,B.,Jr.,"Reconnaissance Geologic Investigation in the Tal- keetna Mountains,Alaska",U.S.Geological Survey,Open File Report 74-147,1974. - "... I I - ,.... ,.. I, - - BIBLIOGRAPHY (CQntinu~d) Csejtey,S.,Jr.,"The Denali Fault of Southern Alaska;The Case for Mi nor Rathar than Major Pi spl acement",Transact ions Ameri can Geo- physicalU~i~.~lVQl ume 61,No •..46,p.1114. Csejtey,B.,Jr.,Foster,H.L.and Nokelberg,W.J.,"Cretaceous Accre ... tion of the Tillkeetna Superterrain and Subsequent Development of the Denali Fault in Southcentral and Eastern Alaska",Geological Society of America,Abstracts with Prosrams,p.409,1980.. Csejtey,S.,Jr.,and Miller,R.J.,Map and table describing metalli- ferous and selected non-metalliferous mineral deposits,Talkeetna Mountains Quadrangle,Alaska,U.S.Geological Survey,Open File Report 78-588 ...B,1978. Csejtey,B.,Jr.,Nelson,W.H.Jones,D.L.,Silberling,N.J.Dean,R.M. Morris,M.S.Lcwphere,M.A.,Smith,J.G.and Silberman,M.L., "Reconnaissance Geologic Map and Geochronology,Talkeetna Moun- tains Quadrangle,Northern Part of Anchorage Quadrange and South- west Corner of Healy Quadrangle,Alaska",U.S.Geological Survey, Open FileR~port78.558A,1978.. Csejtey,B.,Jr.,Nelson,W.H.,Lanphere,M.A.,and Turner,D.L., "Trondhjemite in the Talkeetna Mountains,Southcentral Alaska", U.s.Geological Survey,Professional Paper 1150, 1979. Cummins,A.B.,and Given,L.A.,SME Mining Engineering Handbook,The American Institute of lV,ining,Metallurgical and Petroleum Engineers,Inc.,Volume 1 and 2,1973. Dames &Moore,Inc.,Subsurface Geophysical Exploration -.Proposed Watana Damsite on the SLisitna River,Alaska,Department of the Army,'Contract No.DCAWB5-76 ...C-0004,1975. Davies,J.,and Berg,Eo,"Crustal Morphology and Plate Tectonics in Southcentral Alaska",Bulletin of the Seismological Society of America,Volume 63,No.2,1975.. Deere,D.U.,"TechniCal Description of Rock Cores for Engineering Pur- poses",RockMechanics and Engineering GeologY,Volume 1,1963. Deere,D.U.,"Geologic Considerations"in Stagg,K.G.,and Zienkiewicz, O.C.(eds.),Rock Mechanics in~ngineering Practice,John WileyandSons,1968~..... Deere,D.U.,Hendron,A.J.,Jr.,Patton,F.D.,and Cording,E.J., I!Design of Surface and Near ...Surface Construction in Rock",8th Symposium on Rock Mechanics,Minnesota,1966. BIBLIOGRAPHY (Continued) Deere,D.U.and i"liller,R.P.,"Engineering Classification and Index Properties for Intact Rock",Technical Report No.AFWL-TR-65-116, U.S.Air Force Weapons Laboratory,Kirkland Air Force Base,New Mexico,1966. Deere,D.U.,Monsees,J.E.,Peck,R.B.,and Schmidt,B.,Design of Tun- nel Liners and Support Systems,University of Illinois,1969. Detterman,R.L.,Plafker,G.,Hudson,1.,Tysdal,R.G.,and Pavoni,N., "Surface Geology and Holocene Breaks Along the Susitna Segment of the Castle Mountain Fault,Alaska",U.S.Geological Survey,Mis- cellaneous Field Studies Map MF-618,1974. Detterman,R.L.,Plafker,G.,and Tysdal.R.G.,"Geology and Surface Features Along Part of the Talkeetna Segment of the Castle Moun- tain -Caribou Fault System,Alaska",U.S.Geological Survey, Miscellaneous Field Studies Map MF-738,1976. Ekdale,A.A ••"Trace Fossil Evidence for Deep Water Sedimentation in Cretaceous Arc-Trench Gap,Southcentral Alaska"(abs.),American Association of Petroleum Geologists Bulletin.Volume 63.No.3. 1979. Ferrians.O.J ••Jr.,"Permafrost Map of Alaska".U.S.Geological Sur- vey.Miscellaneous Geological Investigations Map 1-445.Scale 1:250.000,1965. Ferrians.O.J ••Jr.Kachadoorian.R.,and Greene.G.W ••"Permafrost and Related Engineering Problems in Alaska".U.S.Geological Survey. Professional Paper 678,1969. Feulner.A.J.,"Water-Resources Reconnaissance of a Part of the Matan- uska-Susitna Borough.Alaska".U.S.Geological Survey.Hydrologic Investigations Atlas No.HA-364.1971. Forbes.R.B ••Smith,T.E.,and Turner.T.L ••"Comparative Petrology and Structure of the MacLaren.Ruby Ridge and Coast Range Belts:Im- pl ications for Offset Along the Denal i Fault System"(abs.).Geo- logical Society of America.Cordilleran Section,1974.----- Fuch.W.A ••"Tertiary Tectonic History of the Castle Mountain -Caribou Fault System in the Talkeetna r~ountains.Alaska".Geological Society of America.Abstract Programs,Volume 11.No.7.1979. Gatto.L.W ••Merry,C.J ••McKim.H.L ••and Lawson,D.E ••"Environmental Analysis of the Upper Susitna River Basin Using Landsat Imagery". CRREL Report 80-4.1980. ~, - -I - r - - -, BIBLIOG.RAPHY (CQntinw~d) Geqne~~Q1Ldw.~fgt~~a~..~.~~~rfnq~...M~Wnt~~~~JAf~~~ejte&;V~l~""~~~W~~~'l~i't~~ stitute~Univ~:lf$ity ··of Al~sKihpreP4reQ fqr'P;~!Arnw Corpl?of Engineer~~1975, Gedney,L"and Viin Wormer~J,D.~"Sgm!=!Aspepts of Active Tectonism in Alaska as seen on ~RTS~l (~qrth ReSourGes TechnoloaY S?tellite~+) lmqgery'!,U,5,...J~at i ana 1 •Aenmauti eli.and space.'Ad,mi niliitrat ionSpecialPublication~21,l973,,'..'. Hamel,L"and Nixon,D.,"E~Giil/atiQn of Wprlq!s Largest UnqergrpLjnd Powerhouse",Journal pf the Construction Division,ASCE,September1978.'...'.. Harr i 5,N,B"Late.Tertiary FiiUlts ...in Southcentra lA 1aska,(unpubl i sh- ed),Masters'Thes is,Stanford Uni varsity,~97f,." Haugen,R.K"TLlinstra,~.L"aoq SlilUghter~C,W q "A ~anqsat Pat?Col- lection Platfgfm at Devil Canyon Site,UPPer Susitna Basin, Alaska",CRREL Special Report 79-2~AD AG6a5G8~1979, Henqron,A,J.,Jr.,!!Mf2chiinical Properties qf Rock",;n stagg,K,G" and ZienkiewiC;f~G.,(eds,)~ROGk Meehiinics;;in En~ineerJns Practice~Jo~n WileY M10 Sons~1968,' Hill~ouse,J,W.,"Paleomagnetism of the Triassic Nikolai ~reenstqne~ McCarthy Qllgclrangle~Al aSka!!,Canadian Journal af ~art~Sciem:e, Volume 14 ~pp,2?78~?592"1977. Hoek,Eo,Pend Brawn"E,T~"Undergrouncl Excavations in Roc~~lnstitwte of Mining and MetiillllfQY"~ondqn~19130, Jaeger,C,'!Present Trends in the D~s;;ign af Pressure T\.!nnels @no Shafts far Wndefgrouno Hyoroelectric Power Stations'!~PrQc:§e<:tings of Institute of CiVil Engineers"March~~955, Jasper,M.W.,"Geochemical Investigations Along Highway iHH:I Sec;onoary Roads in ~quthcentral Alaska",Alaska Division of Mines;;and Mi nera 1s ~.§eochemi Cil 1 R€:lport .No,7"196(:1, Johnston,G.H,"(eo,)"Permilfrost Ens;neeri ns pesi ~nilnd .'Gons!fH£tjpr, John WileY anc1 Son§,,1981,.... Jones"P,L~,Silpi3rling,N,J"Csejte,y~~,~Jr,,,Nelsl:W"W,H~"And Bloome~C,Q"'IAge ancl S,tructufi3.1 Significance of Ophiolite i3.nd Aojoining RQck~in the Upper Chulitna Piitrict,,~Quthalntral A1ask al!"U,S.~e~l~~i~~l.JH.rV~YJ Professi8D~J,~~~!rJ.~gt:~"l~ap, Jones,D.L.,and Silperling,N.J.,"Mesozoic;Striitigraphy~the KeY to Tectonic AnalYsis of Southern and Central Alask(l!',U,5,~eologiciil Survey"Open Fi 1e Report 79 ..1200,1979.'" BIBLIOGRAPHY (Continued) Jones,D.L.,Silberling,N.J.,and Hillhouse,J.,"Wrangellia - A Dis- placed Terrain in Northwestern North America",Canadian Journal of Earth Science,Volume 14,pp.2565-2577,1977. Kachadoorian,R.,"Geology of the Devil Canyon Damsite,Alaska",U.S. Geological Survey Report to U.S.Bureau of Reclamation,1958. Kachadoorian,R.,"Geology of the Devil Canyon Damsite,Alaska",U.S. Geological Survey,Open File Report 74-40,1974. Kachadoorian,R.,Hopkins,D.,and Nichols,D.,"Preliminary Report of Geol ogi c Factors Affect i ng Hi ghway Construct i on in the Area Be- tween the Susitna and Maclaren Rivers,Alaska",U.S.Geological Survey,Open File Report 54-137,1954. Kachadoorian,R.,and Pewe,T.,"Engineering Geology of the Southern Half of the Mt.Hayes A-5 Quadrangle,Alaska",U.S.Geological Survey,Open Fi 1e Report 55-78,1955. Kachadoorian,R.,and Moore,H.J.,"Reconnaissance of the Recent Geo- logy of the Proposed Devil Canyon and Watana Damsites,Susitna River,Alaska",Exhibit 0-2,U.S.Army Corps of Engineers Report, 1978. Karlson,R.C.,Curtin,G.C.,Codey,E.F.,and Gormezy,L.,"Geochemi- cal Maps of Selected Elements and Results of Spectrographic Analy- ses for Heavy Mineral Concentrates from the Western half of the Talkeetna Mountains Quadrangle,Alaska",U.S.Geological Survey, Open File Report 77-530,1977. Karlstrom,ToN.V.,"Quarternary Geology of the Kenai lowlands and Glac- ial History of the Cook Inlet Region,Alaska",U.S.Geological Survey,Professional Paper 443,1964. Karlstrom,ToN.V.,and others,IIS ur ficial Geology of Alaska",U.S. Geological Survey,Miscellaneous Geological Investigations Maj? 1-357,1964. Kaufman,M.A.,"Geology and Mineral Deposits of the Denali-IVlaclaren River Area",Alaska Division,Geological and Geophysical Survey, Report 4,1964. Kri nitzsky,Eo L.,II Earthquake Assessment in the Susitna Pr oject, Alaska,U.S.Army Waterways Experiment Station,1978. lahr,J.C.and Kachadoorian,R.,"Preliminary Geological and Seismic Evaluation of the Proposed Devil Canyon and Watana Reservoir Areas,Susitna River,Alaska ll ,Informal Report to the U.S.Army Corps of Engineers,1975. 1'!0'-", - - - ,.... r- i - -, -,, BIBLIOGRAPHY (Continued) Lahr,J.G.,Petailed Seismic Investi ation of Pacific -North American Plate Inferclclibn in Southern Alaska unpublished,Ph.D. Disser"tTon,··C6111111bi a University,1975. Lathram,LH.,and Albert,M.R.,"Significance of Space Image Unears In A1Clska'l,in First International Conference of New Basement Tectonics Proceediri 5,Salt Lake Cit,Utah,1974,Utah Geoloical Associafion~Publication-,1976. Lathram,LH.and Reynolds,R.G.H.,"preliminary Space Image Lineament Maps of Alaska",U.S.Geological Survey,Open Fne Report 76-341,1976................ Maevis,A.C.,and Hustrulid,W.A.(eds.),Proceedings :-1979 Rapid Excavation and Tunnelling Conference,Volumes 1 and 2,June 1979. McGee,D.L.,and Henni n9,M.W.,'I Reconnai ssance Geology -Southcentral Talkeetna Mountains,Alaska",Alaska Division of Geological and ~eophysical Surveys,Open File Report 103,1977. Miller,J.M.,Belon,A.E.,Gedney,L.D.,and Shapiro,L.H.,"A Look at Alaskan Resources with Landsat Data",International Symposium on Remote Sensi ng of the Environment,Proceedings 10,Vol ume 2, 1975. Miller,R.J.,Cooley,E.F.,O'Leary,R.M.,Gormezy,L.,Csejtey,B., Jr.,Smith,T.E.,and Cleveland,M.N.,"Analyses of Geochemical Samples from the Talkeetna Mountains Quadrangle,Alaska",U.S. GeoloQicalS~rye,y,Open Fi le Report 78-1052,1978. Miller,R.J.,Curtin,G.C.,and Csejtey,B.,Jr.,"l~ap Showing Geo- chemical Distribution and Abundance of Selected Elements in Stream Sediments and Heavy Mineral Concentrates,Talkeetna Mountains Quadrangle,Alaska",U.S.Geological Survey,Open File Report 78-558,1978.- Moavenzadeh,F.,and Markow,M.J.,"Simulation Model for Tunnel Con- struction Costs",Journal for the Construction Division,ASCE, March 1976. Moffit,F.H.,"Hea,dwater Regions of Gulkana and Susitna Ri vers, Alaska'l,U.S.Ge~losical Survey,Bulletin 498,1912. Moye.D.G.,!'Rock Mechanics in the Investigation and Construction of T.l.Underground Power Stiltion,Snowy Mountains,Australia", EngineerinQGeology Case Histories,Number 3,Geological Society of AmerH:a,1964~.-..... NPAS (North Pacific Aerial Surveys,Inc.),Control Survey Manuscripts for R&M Consultants.1981. BIBLIOGRAPHY (Continued) Nelson,S.W.,and Reed,B.L.,"Surficial Geologic Map of the Talkeetna Quadrangle,A1aska",U.S.Geological Survey,Miscellaneous Field Studies MF-870J,1978. Obert,L.,and Duvall,W.I.,Rock Mechanics and the Design of Struc- tures in Rock,John Wiley and Sons,1967. Packer,D.R.,Brogan,G.E.,and Stone,D.B.,"New Data on Plate Tecton- ics of Alaska",Tectonophysics,Volume 29,pp.87-102,1975. Pewe,T.L.(ed.),"INQUA Conference:Guidebook to Central and Southcen- tral Alaska",VII Congress of the International Association for Quaternary Research,1965. Pewe,T.L.,"Quaternary Geology of Alaska",U.S.Geological Survey, Professional Paper 835,1975. R&M Consultants,Aerial Topographic Map of Devil Canyon Reservoir, Scale 1 inch =400 feet,1981. R&M Consultants,Devil Canyon Climate Data,April 1980 through July 1981,198!. R&M Consultants,Watana Climate Data,September 1980 through May 1981, 1981. Reed,B.L.,"Disseminated Tin Occurrences Near Coal Creek,Talkeetna Mountains 0-6 Quadrangle,Alaska",U.S.Geological Survey,Open File Report 78-77,1978. Reed,B.L.,and Nelson,S.W.,"Geologic Map of the Talkeetna Quad- rangle,Alaska",U.S.Geological Survey,Miscellaneous Field Stud- ies Map MF-870-A,1977. Reger,R.D.,"Reconnaissance Geo1ogy of the Talkeetna-Kashwitna Area, Susitna River Basin,Alaska",Alaska Division of Geological and Geophysical Surveys,Open File Report 197A,1978. Richardson,H.W.,and Mayo,R.S.,Practical Tunnel Driving,McGraw- Hil1,1941. Richter,D.H.,and Jones,D.L.,"The Structure and Stratigraphy of Eas- tern Alaska Range,Alaska",American Association Petroleum Geologists,Memoir 19,1973. Richter,D.H.,"Geology of the Portage Creek -Susitna River Area", Alaska Division of Geological and Geophysica1 Surveys,Report 3, 1964. - - BIBL10GRhPHY (Continued) Richter~D.H.,and Mason,N.A.,Jr.,"Quaternary F(l.ult;ng in the E(:is" tern Alaska Range",GeQlosicalSurveyofAm~rlcq Bulletin.Volume82,19n.-----o -••'•••-•••••••••••--.•• Rieger,S••$choephOfster,0.6.,and Furbush~C.E.,"Exploratory Soil Survey of Alaska",Son Conservation Service Reeort,1979. Rose,A.W ••"Geology of an Area on the Upper Talkeetna River. Talkeetna Mountains Quadrangle,Alaska Divisfofl of Geological and Geopt\Ysi ... cal Surve,ys.Report 32.1967.....-... Rosenstrorn.S.,"Kafue Gorge Hydroe 1ectr ic Power Project".Water Power, June-J uly.1972.'--... Rousseau.F••"Bersimis ..l(l.c Casse Hydroelectric Power Development",The Eng i neer ins J ourna 1.Apr il 1956..-....- Sayles.F.H ••"Procedure for Estimating Borehole Spacing and Thaw ...Water Pumpi ng Requirements fOr Art ifi cia lly Thawi ng the Bedrock Perma- frost in the Watana Damsite",U.S.Army Corps of Engineers Ree9rt(CRREl).1979......................-' Shannon &Wilson,Inc.,Seismic Refraction Survey,Susitna Hydroelec- tric Project,Watan(l.and Devil Canyon Damsites.1978.'..-,,-'._,-.,"",-,-",,'".-"".'_.--,.__.. Snberling.N.J.,and Jones.D.L.,Csejtey,B••Jr.,and Nelson.W.H •• "Interpretive Bedrock Geologic Map of Part of the Upper Chul itna District.(Healy A..6)Alaska".U.S.Geological Survey.Open File Report 78 ...545.1978....'.--' Stagg.K.G ••and Zienkiewicz,0.0.(eds.),Rock Mechanics in Engineer- ing Practice.John Wiley and Sons.1968...... Smith.I.E.."Regional Geology of the Susitna-Maclaren River Area". Alaska Division of Geological i;lnd GeophysicalSl,lrveys.AnnualReporf.1974...-.".......q -•._no'.•••'. Smith,T.E.,Bundsten.LK ••and Tribble,T.C ••"Stratabound Copper'" Gold Occurrence.Northern Talkeetna MOl,lntains.Alaska",Ali;lska Division of Geologici;ll i;lnd Geoph,ysici;ll Survey&.Open File ReportE.1975..-,.........-.,.......-..-'.-. Sl11ith,T.E.,and Lanphere.M.A ••"Age of the SedimentatiQn,Plutonism and Regional Metamorphism in the Charwater Mounti;lins Region of Central Al ask¢lll.hochron West.No.2,1971. Steele.W.C ••"Map Showing Interpretation of landsat Imagery of the Talkeetna Mountain$Quadrangle,Ali;lska".U.S.GeQlo~ical SurvetOpenFileR,e.e ort 78 558 ..0.1978..,--"_m· BIBLIOGRAPHY (Continued) Stone,D.B.,and Packer,D.R.,"Tectonic Implications of Alaska Penin- sula Paleomagnetic Data",Tectonophysics,Volume 37,pp.183-201, 1977 • Texas Instruments,Inc.,"Aerial Radiometric and Magnetic Reconnais- sance Survey of the Eagle-Dillingham Area,Alaska",Report GJBX- 113-78,1978. Travis,R.B.,"Classification of Rocks",Quarterly of the Colorado School of Mines,Volume 50,No.1,1955. Turner,D.L.,Smith,ToE.,and Forbes,R.B.,"Geochronology and Offset Along the Denali Fault System",(abs.),Abstracts with Programs, 70th Annual Meeting,Cordillerian Section,Geological Society of America,Volume 6,No.3,1974. u.S.ArmY Corps of Engineers,Hydroelectric Power and Related Purposes, Upper Susitna River Basin,Southcentral Railbelt Area,Alaska, Interim and Final Feasibility Reports,1975 and 1978. U.S.Army Corps of Engineers,Petro ra hic Examination of Led e Rock, Re ort Series Numbers 1 and 5 78/138 and 78/207 ,Missouri River Division,Omaha,Nebraska,1978. u.S.Army Corps of Engineers,Susitna Project Geology Field and Survey Books,Numbers 1 through 28,Susitna,unpublished,1978. u.S.ArITJY Corps of Engineers (Alaska District),"Snettisham Hydroelec- tric Project". u.S.Army Corps of Engineers,Susitna Project,Re ort of Tests on NX Rock Cores for Talkeetna and Watana Sources 78-C-305,North Pacific Division Materials Laboratory,Troutdale,Oregon,1978. u.S.ArITJY Corps of Engineers,Report of Tests on NX Rock Cores and Ledge Rock,Talkeetna Flood Control Project,North Pacific Divi- sion Materials Laboratory,Troutdale,Oregon,1979. u.S.Army Corps of Engineers,Tunnels and Shafts in Rock,EM 1110-2- 2901,1978. u.S.Bureau of Reclamation,"A Report on the Potential Development of Water Resources in the Susitna River Basin of Alaska",u.S.Bureau of Reclamation,Alaska District,1953. u.S.Bureau of Reclamation,Devil Canyon Project,Potential Develop- ment:Design Notes and Calculations,1952. U.S.Bureau of Reclamation,"Devil Canyon Project,Alaska -Feasibility Report",U.S.Bureau of Reclamation,Alaska District,1960. BIB~IOGRAPHY (Continued) u.s.Burealj of RlilClarngti{"l!1,"Engineering Geology Report~Pea~ibility ~ti'!~th DfilVil GaRyqn Darn,Devil C,gnyon Proje9t"~A laskaGeol,o~ic ReportLN~.,7~1960..'...... U.S.Bureau of Reclamation~"Engineering Geology of the Vee Canyon Darn .. $.i1;e,Vee Canyon Project,Susitna River~Alas;ka",U,S.Bureau of Reclamation,Alaska District,1962.' ". U.S.Bljreau of Reclarnation~!ILpboratory Tests on Concrete Aggregate from Devil canyon Darnsite ..Alaska",Concrete Labof.;itoryReportC..932 ~19~9,.".'.,,...'.,".,.'".......,.'.' U.S.Bureau of Reclamation,"Laboratory Tests of Foundation Rock Cores from D(:lvil Canyon Darnsite,Devil'Canyon Project ..Alaska",Can .. crete Laboratory Report C-933,1960. VanEysinga,P.W.B.,Geologic Tirnetable,Jrd Edition~Elsevier Scientif- i cPu b1 ish i ng Camp ~ni~Arnste'y'laarn~1975. Van Wormer,J.D.,Davies~J.~qnd Gedney,L.,"Seismicity anct Plate Tectonics in Southcentral Alaska'!,Bulletin of the SeisrnolQsical Socie\Y.Qf.Am~Li.ca,Yo:l ume64,1974.",.,...,' Vasilescu,M.S.,Ben$.iger,C.P.,and Kwi atkowski ~R.W.,"Design of Rock Caverns for Hydraljl ic Projects",Undergr ound Rock Chambers,ASCE,1971..'....,'..,'"," Wa,hrhpftig,C.,"QLjaternary Geology of the Nenana River Valley and Adjpcent Parts of the Al ask a Ra nge"~U.S.Geolo~i cal Survey,1'1"0- fe$sional Paper 293..,1~1958..'p ••.•.• Wqhrhaftig,C.,and Black,R.F.,'!Engineering Geology Along Part of the Alaska Railroad",U.S.GeoloQical Survey,Professional Paper 293-6,1958. Wheby~F.T.,and Cikanek,E.M!!!'A Computer Program for Estimating Costs af Tunneling ",~e8o.rt Preparedfor Federal Railroad Adminis- trati on by HaNa EflQi neering CompanY','Chi caga,In i nois,October1973."'".",,.. Whitten,O.,G.A.,anct arooks,J.R.V.,A Dictionary qfGeoloQ,y,Penguin BOOKS,En9lanct,495 p.,1972, WOQq~lgrd ..Clyde Con$uHqnt!i,Final Report..,Susana Hydroelectric Pro- jt=Gt,Sei$mic RefrgctiaflSU.rV~»19'8a.· WO(ldward..,Clyde CO!lsultant$,Interim ReportonSeismiQStudiesfor $U$-itng HtdroeJ~ct~ioPI:Qjec~;T9mJ,;"'.'"n ".''".'.••••.•••••.••• Woodward ..Clyde consultants,Fi nal Report -Susana Hydroelectric Pro- ject.Seismic RefractionSurv~y~1981~ BIBLIOGRAPHY (Continued) Woodward-Clyde Consultants,Final Report on Seismic Studies for Susitna Hydroelectric Project,1982. Yould.Eo,"The Susitna Hydroelectric Project",Northern Engineering. Volume 8,Numbers 3 to 4.1976. r;r- - r -I APPENDIX B WATANA DIAMOND CORE DRILLING LOGS "]'1 --1 -1 J 1 1 }-1 l Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG SUMMARY LOG • Alteration zone. REMARKS Shear - Shear. Alteration zone. Fracture zone. Shear/alteration zone. Shear/alteration zone. Shear/alteration zone. Shear. Shear/fracture zone Fracture/alteration zone. Job No.P570~0~.0~5~__ Hoi e N 0.---.!lli..::.J. Sheet No._2_of __3_ 560 200 Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site _Watana_iSillJlliJJank) 620 660 -j I [ I III [ I 520 DEPTH (FT.) 540 420 500 640 I I [ [III I f- 480 580 I I [+-I+H 600 380 360 400 440 680 +--I I I [I [1-1- 460 • REMARI($ Alteration zone. Fracture zone. Alteration zone. Di ke,mafi c. TOP OF ROCK 27.0' Shear. Shear. Shear. tl Shear zone. Job No.P5700.05 Hole No.~ Sheet No._1_of _3_ ROCK TYPE Andesite Diorite ROD % CORE:RE:CO'v'ERY % Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana (South Bank) D(~~~I ~~.~. I I C+++-I--l-I I I 1 I I I I I I I I-+-[[ I I I Overburden Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana (South Bank)_ Job No.~00.05 Hole No.__B~ Sheet No._3_of _3_ DEPTH (FT.) no 740 760 780 800 ROCK TYPE rt-t-i-l-i Quartz4-1-++-1 Di 0 rite ", REMARKS ear. Shear. Shear/alteration zone. Dike,felsic. Shears. Shear. END OF BORING 798.9' • 'I '1 J ')1 ']-']..-}-, Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.COE DH-l Site Watana Sheet No._1_of _1_ PERMEABILITY CORE RECOVERY RaD NUMBER OF DEPTH [LEV.0.;)cm/uc.%%JOINTS PER ROCK TYPE REMARKS(fT.)(FT,)10FT IQ-6 10-4 IO~2 20 40 60 eo 20 40 GO eo 5 10 15 20 0 1459 Overburden 20 40 TOP OF ROCK 43.8' f---1409 fill Quartz r Shear,breccia. 60 r--Diorite 80 ~--- 100 -1359 c--]Shear,fracture, alteration zone. Dike andesite.120 -- END OF BORING 122.8'140 1319 c-c- ------~ -- ~- ----I- -------- - -f-e--- -------1------- • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.0_1__ Project Susitna Hydroelectric Project Hole No.COE DH-3 Site Watana Sheet No.__1 _of _1_ PERMEABIL.ITY CORE RECOVERY RaD NUMBER Of DEPTH ELEV.'K)om /Ut,%%JOINTS PER ROCK TYPE REMARKS/FT,}(FT.)lOfT, 10-6 10-4 10,2 20 40 60 eo 20 40 60 80 5 10 15 20 -0-1458 Overburden 20 40 -408 60 TOP OF ROCK 77,6' 80 f---Quartz II Di orite 100 358 ---- 120 14tr ,," 160------- -------- 180--J 278 -END OF BORING 174.5' ---- ---- -~--- ---- --- -- - • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG REMARKS END OF BORING 176.9' Andesite porphyry(? • TOP OF ROCK 59.6' Alteration zone. Job No.P5700.05 __ Hole No.COE DH-S Sheet No._1_of _1 _ ROCK TYPE Overburden Ouartz Di orite! Grano- diorite l NUMBER OF JOINTS PER 10FT. 5 10 15 20 PERME:ABILITY I CORE RECOYERY I ROD (K)em/Bec %% 10-5 lOA 10-2 20 '10 60 80 20 40 60 so Client-.AUlSKA POI-lER AUTHORITY Project .....susitna Hydroelectric Project Site_..JoIatana 20 40 I I I 1-+ o 11461 60 -l----+-+--l ~+++-+-+++-+ 1411 80 D(~T~~I ~;~_~. 120 100 Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Client-----.1\lJl.SKA POWER AUTHORITY Job No.----.!'5l00.05 __ Project _Susitn~Hydroelectl'ic Project __Hole No.COE DH-4 Site Watana Sheet No._1_of __1_ PERMEABILITY CORE RECOVERY RQD NUM8ER OFD(E~~~~~~.~(K)cmh\lc.%%JOINI~SFTPER ROCK TYPE REMARKS -,0_6 lOA 10-2 20 40 60 80 20 40 60 eo 5 10 15 20 o 1461 Overburden 20 - --- 40 --1 f--I-f--f-- --1411 i-[I tt-f--f-- ~-~-q::it -J++-+--H·+-+-+-t+-Ouartz TOP OF ROCK 70.0' 80 -f-~Diorite ----f--- 100 -~361 -1---JCore loss 4.3'. ----- 120 f--_ -----h I -t -'1 EN01~;~9RING "0:-:-llliill·~J-C ..... ----Lt~+-1----,i ~-iJ I -c---i ~::::~:=j t~--~.~1-_~__I - =c---~-1 ++-------c--+'-+-+-+-1-+-+--+ --~'I I----+-++I-+t 1-----j--- - -j t+-+--+-+---+.J-+-+-+-+--! --I • ~"l l ~"j ~~j ~ cd :J Cl ~""'~'1 ,~,c-c'l F~C-'']"c-'l ~'-l ''''''-'']'] __C)--I J J Acres American Incorporated -Consulting Engineers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.COE DH-7 Site Watana Sheet No._1_of _1_ PERMEABILITY ICORE RECOVERY ROD NUMbER OF DEPTH ELEV.(tel em/sec.%%JOINTS PER ROCK TYPE REMARKS{FT.l (Ft.)IOFl. 10"6 10-4 10-2 20 40 60 80 Z04QWeo 510152Q 0 1716 uverDur en TOP OF ROCK 8.5' Diorite! 28 Ouartz Di orite 40 I---1673 -~Shear!alteration zone. 60 I---b Zone of four closely spaced 80 felsic dikes. 100 1630 120 , END OF 80RING 140 159&122.2' r-f---- -- ---- m REMARKS [iJ Alteration zone. TOP OF ROCK 3.5' Job No.P5700.05 Ho Ie No.COE DH-6 Sheet No._1_of 1_ ROCK TYPE NUMBER OF ,JOINTS PER 10FT. 5101520 Quartz I I I I I +-J Diorite Diorite!rr-t+-t-t++-i Qu artz!:l::--l-+-+-+-Di 0 rite ROD % SUMMARY LOG Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana 80 100 ~F,oc'"""OO, 120 l Fracture zone. 140 I END OF 80RING 149.6 ' Acres American Incorporated -Consulting Engineers Buffalo,New York Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG SUMMARY LOG Job No.P5700.D5 Hole No.CDE "'DH'---"'S__ Sheet No.__1_of _1_ REMARKS Fracture zone. END OF BORING 284.2' Fracture zone. TOP OF ROCK 5.6' Breccia,healed with green igneous rock. Shear/fracture zone Jlndesite dike. Job No.P5700.05 Hole No.COE DH-9 Sheet No._1_of 1 ROCK TYPE Di orite Felsic Dike NU"'SER OF JOINTS PER 10FT. 5 10 15 20 Quartz 11-+-++++-1 Di a ri te Client_JlLASKA POWER--'A-"'U"-T'-CHO"'R"'I..!.TY'----_ Project _Susitna Hydroelectric Project Site W_atana END OF BORING 150.0' REMARKS TOP OR ROCK 16.2' Series of shear zones,(3)0.5" each. Breccia healed quartz diorite in andesite matrix. Di orite ROCK TYPE Overburden quartz Di orite NUMBER OF JOINTS PER 10FT 5 10 15 20 ROD % COR E AECOVERY % Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watan."---____ . _ D(E:T~~I ~;~,~. •m ~~].~~',"J'~J )}~, ""~rl "~l ~"~-l ''''''~1 -"~"l ,,,,,,,],,""'1 ""1 -,~J ''''''''')~l 1 '] Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG SUMMARY LOG Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana Job No.~00.05 Hole No.COE DH-JO S heel No.__1 ~of ,,_J_ Cllent ALASKA POWER AUTHORITY Project Sus Hna Hydroel ectri c Proj ect SiteWatana Job No._P5700.05 Hole No.COE DH-ll Sheet No._1 of _1_ Dike,andesite (?) Fractu re zone. END OF BORING 300.0' REMARKS TOP OF ROCK 22.7' Shear!a lterati on zone. Shear!a lterat ion zone. --Fracture zone. Fracture zone. ROCK TYPE NUMeER ,OF JOINTS PER 10FT. 5 10 15 20 RQD % CORE RECOVERY % 80 40 I I I I I I I I I II I I I I 1 Di orite 60 260 ~~7r J ~~.~. 280 ' 180 140 300 240 160 no 200 120 JOO I "F U I I ++H I III I I:i I I I I I I I I Overburden RE,M,AR KS END OF BORING 203.5' Fracture zone. TOP OF ROCK 19.6' Oiorite brecci a in andesite. Alteration zone. Diorite breccia in andes ite. 1 1 Oi orite brecci a in andesite. I Alteration zone. FlOCK TYPE NUMBEI'l OF .jOINTS PER .10FT. '5 10 15 20 DEPTH ELEV.PE'RMEABIL;lTY ICORERECOYERY I AGO 1FT.)(FT.)(K),~m/nc.%% 10-6 ]0-4 10-2 0 2033 20 40 60 80 - 100 120 140 160 ,180 200 ;;±3 liJ • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG SUMMARY LOG Client Project Site ALASKA~OWER AUTHOR~IT~Y _ Susitna Hydroelectric Project Watana Jo b NO ..-f'.5lQQ·05 _ Hoi e N o.----.IQl;.Jl.H..::lL Sheet No._1_of 1 CI i ent------"lLAS KA POWER AUTHORITY _ Project _--.SlLsi1Da Hydroe 1ectri c Proj e_c,-"t~_ Site Watana Job No.P5700.05 Hole No.COE DH-21 Sheet No._1__of _2_ REMARKS Alteration zone. • Alteration zone. Alteration zone. Alteration zone. Alteration zone. TOP OF ROCK 84.5' ROCK TYPE i-- NUMBER OF JOINTS PEA 10 PT 5 10 15 20 ,I I I I j--1Quartz Di orite AOD % PERMEABIL.ITY ICORE RECOVERY (K)em/sllc."/':1 10.6 10.4 10-2 o 11478 +-l-+-H-l--l--+--\-+-l-l-t--I--J--j-I I I I I \ IOverburden 20 I 1 I 11-++++--++-+-H-++I I I I I I I I 40 ----+1436 60 co ~~~~I ~~~\ 340 12C 140 =!351- ~::J;±~9 - 220 240 --1 1267 260 280 ;;t~ - 320 100 • REMARKS ENO OF BORING 301.1' 291.3-295.5 Shear zone,healed. TOP OF ROCK 9.5' Fracture zone, minor shears. 177-184.3 Shear/ alteration zone. Shear/alteration zone. ROCK TYPE Ovel-burden NUMBER OF JOINTS PER 10 FT_ 5 10 15 20 Oiorite/ t-++-+--+--1 Qua rtz Diorite Quartz -+--t-+-+H Di 0 rite I .I PERMEABILITY ICORE R'COVERY I AO D~~~~~~~~'(Kj cmjelC."I"% 0 20 ,;i-~,!~I 1901 LL I )- OJ60-I-~- -G I -0', o --1---~;::,(T,I <1!,z ~1_8~ 120 140 --+1801 160 180 200 -- 220 240 -+170 26 28 30 - 32 "J ~'--1 ~-'J ["'~--l '--1 '=--"""1 ·····-1 -1 ,····'"'1 e',_.]-1 J 1 1 Acres American Incorporated -Consulting Engineers Buffalo,New York Job No.P5700.05 Hole No.CaE DH-2l Sheet No._2_of _2_ SUMMARY LOG Client ALASKA P.OWER AUTHORITY Project Slisitna Hydroelectric Pro'ject Site Watana ROCI<TYPE Quartz1-1-+1.-+1...jl.-+...jl Di 0 rite I I I I Andesite OuartzI I 1 1 1 1 I Oi orite 620 REMARKS Alteration zone. Alteration and sheared zone. END OF BORING 603.7' • Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.CaE DH-23 Site Watana Sheet No._1_of _1_ PERM".'CITY ICORE RECOVERY ROO NUMBER OF' DEPTH ELEV.(K)em/tlc.0/0 %,JOINTS PER ROCK TYPE REMARKS(FT,)(FT.)10FT, 10-6 10-4 10-2 20 40 60 80 20 40 60 eo 5 10 15 20 0 195L Overburden TO~Ie HI CK r2 0 I Diorite T + '40 -r--i --1902 ):-pShear/fracture zone0,nO r--;:;:~Shear/fracture zone ~..I---:'!....P Shear/fracture zone. !""" faa e-Ll "~Shear/fracture zonaOl l85e ~lOa ,Mz: 120 1832 END OF BORING ]]9.2' c---1---- --- . • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client AI ASKA POWER AIITHORITY Project Susitna Hydroelectric Project _ Site_Watana Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client __ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna~droe1ectric Project Hole No._Iill'___lli:L::2_8__ Site Watana Sheet No._1__of __1_ PERMEABILITY CORE AECOVERY ROO NUMBER OF OEPTH ELE\!.lKJ em/sec.%%JOINTS PEA ROCK TYPE REMARKS(FT )(FT,)10FT. 10-6 IDA 10-2 20 40 60 80 20 40 60 80 5 10 \5 20 0 19/I I I Overburden _LOP OF ROCK 9.2'_ I, Andes ite 20 --Porphyry JShear/fracture zoneI 'rI--- 40 ----_I I I---1921 -r- 60-1----JShear/fracture zon~ -1-- 80 ----- ~-I--Shear/fracture zone. 400 871 I '"Fracture zone. - '120 ...Anop'itp -END OF BORING '140 931 1 125.2 ' ----- j --------- -j I ---- --------- ----It ---- -----------f-I- -- If ----------- -----I ------c-1------------- -- ----------- -- ---- --- -I - - --- u END OF BORING 139.9' • REMARKS Irregular contact with andes ite. Job No._J'5700.05 Hole No._CaE DH-2_4__ Sheet No._1_of _1_ ROCK TYPE verburden t- NUM8ER OF JOINTS PER 10FT. 5 10 15 20 Quartz 11+I I I I IDiorite j 80 100 +1961 140 +1921 I I I I I I \ 120 .~ I I 'H+++IIffHf+++ -Itt]I~I IllUt ~~~11 ,~j~11 ~~1l ~j 1 iJ11_.1 ,I ~j -.1 J d I 1 'J '1 ']'J "'1 1 J -1 ,.,-]1 1 ~))~J j ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT,ALASKA POWER AUTHORITY JOB NO"P5700.05 PROJECT,Susitna Hydroelectric Project HOLE NO"BH-1 SITE,Watana (North Bank)SHEET NO.1 OF 10 CONTRACTOR,Interstate Exploration Inc.DRILLING OATES,August 10 TO August 14,1981 LOGGED BY·.R.R.Henschel DATE,September 1981 LENGTH ,RECOFRUN (FT.)(RQD) - Run 2 21.0 I 96 to (54) 26.0 Run 3 26.0 I 92 to (74) 31.0 JOB NO.P5700.05 HOLE NO.BH-l .SHEET NO.2 OF 10 DESCRIPTION:COLOR,TEXTURE,FOLIATION ,J01NTING,FRACTURING,FAUl.TI NG, ALTERATION,WATER LOSS OR GAIN,CAVJNG,LOST CORE,CEMENTING,ETC. quartz.Fresh to slightly weathered, generally hard to very hard.Joints very close to wide,fresh to slightly weathered with iron oxide staining on surfaces. Carbonate and sulphides common as coating on joints and fractures. 18.7-41.1 -Slightly weathered with iron oxide staining along joint surfaces.No penetrative weathering.Joints closely spaced. 21.2-22.8 -Fracture zones,very close spaced fractures and joints healed with carbonate and iron oxide.Some open fractures very close to close spaced at 0-10°,20°,and 70°. 21.5-21.9 -Core broken by drilling, slickensides on some fragments. ROCK TYPE Quartz Diorite PROJECT Sus itna Hydroe 1ectri c Project SITE Watana (North Bank) CLIENT ALAS KA POWER AUTHOR lTY DEPTH (FT.) 30 (28.2) % REe (RQO) CASING OIAMETER,NW (3.0")I.D. CORE DIAMETER:NQ (1.75")0.0. A.S.P.C.,Zone 4 2049.7 2032.1 1767.9 DE:~~~PRT~~~~~~~~~~T~;5~u~:':A~~I~~~V~N~~I~~I~~~~C.T~~~~~~:~~T~~..I LE~:H N3,227,942 E743,085 030 0 70° Casing Advancer Diamond Core -Triple Tube LATITUDE DEPARTURE AZIMUTH DIP SOIL ROCK iWCK TYPE ELEVATIONS,DATUM MSL, GROUND SURFACE ROCK SURFACE BOTTOM OF HOLE WATER TABLE Depths measured along hole.True depths in (). All angles measured to the core axis. Overburden DEPTH (FT., DRILLING METHOD: LOCATION; NOTES,1) 2) o Run 4 31.0 I 94to(88) 36.0 f---+I---- •. 100 (90) 92 (56) Run 6 41.0 to 46.0 Run 5 36.0 to 41.0 36.95-40.0 -Shear/fracture zone,joints and fractures very close to closely spaced. numerous healed fractures throughout. 37.1 -Possible shear,with 0.25 inch layer of clay and -rock fragments at 40°. 37.4-38.3 -Core broken by drilling, fragments 0.25 to 1.0 inch,average less than 0.50 inch.Core loss of 0.6 feet between 37.4 and 40.6. 38.8-39.4 -Shear,10°,rough,plane with slickensides,chlorite coated,tight. Sulphide mineralization in surrounding rock. 39.5-39.6 -Shear,40°,very tight/healed.I "----I 40 (37.6) 10 (9.4) 18.7 (17.6)I Ouartz Diorite 20 (13.8) TOP OF ROCK Medium gray to medium green-gray,medium grained crystalline rock,non-foliated with 10-15~afics (biotite/hornblende),10-15% Run 1 18.7- 21.0 100 (87) 50 (47.0) 39.4-40.0 -Some minor hydrothermal alteration with feldspars altering to clay 41.1-46.5 -Joints close to moderately clos~y spaced. 49.4-63.9 -Joints closely spaced. Run 7 46.0 to 51.0 I I 100 (86) APPROVED:~~~~DATE;February 1,1982 7 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroel ectri c Proj ect SITE Watana (North Bank) HOLE NO.BH-l SHEET NO.3 OF 10 PROJECT Susitna Hydroel ectri c Proj ect SITE Watana (North Bank) HOLE NO.BH-l SHEET NO.4 OF 10 Run 10 Run 11 66.0 1100 to (gO) 71.2 Run 9 56.1 1100 to (92) 61.0 Run 14 81.1 I 100 to (94) 86.2 98 (86) 100 (100) Run 20 107.0 to III .2 Run 21 111 .2 to 116.3 LENGTH I REe OF RUN(FTl (ROD) ~un 15 86.2 I 100 to (88) 91.2 Run 16 91.2 I 90to(62) 96.2 Run 17 96.2 76 to (68) 101.2 f-----JRun18 101.2 100 to (44) IlOU- Run 19 103.9 I 100 to (97) 107.0 DESCRIFTI ON:COLOR,TEXTURE,FOLIATION,,JOINTING,FRACTURING,FAULTl NG, ALTERATION,WATER lOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 115.0-125.0 -Core medium to dark gray. gray-green and light gray due tovariation in mafic minerals. 93.1-96.5 -Fracture/alteration zone,light gray,moderately hydrothermal altered.joints very close to close spaced,moderately hard to hard,friable locally. 91.2-181.0 -Drilling water return generally less than 50%. 94.2-96.2 -Core loss 1.2 feet. 96.5-99.4 -Occasional healed fractures, 99.4-101.2 -Healed breccia,hard. 100.15-101.2 -Core loss 1.05 feet.Some clay at 100.15. 101.2-117.2 -Healed breccia.irregular fragments of quartz diorite in a medium green-gray,very fine grained quartz diorite matrix,hard to very hard.Some quartz healed fractures.Minor hydrothennal alteration locally.numerous quartz stringers and pods. ROCK TYPE Quartz Diorite I 86.3-96.5 -Healed breccia.quartz diorite fragments in a fine grained quartz diorite matrix with some minor hydrothermal alteration along joints. 86.3-86.9 -Mineralized vein,less than 0.25 inch at 86.65.possible shear. 89.1-93.1 -Joints very close to close spaced. DEPTH (FT.) 100 (94.0) 90 (84.6) 110 (103.4) REG (ROO) 100 (76) LENGTH OF RUN 1FT.) Run 8 51.0 to 56.1 61.~[100to(80) 66.0 , ------ Run 13 76.2 1100 to (88) 81.1 Run 12 71.2 1100 to (94) 76.2 75.9-76.1 -Joints at 50°and 15 0 ,respectivel>1 with clay coating,sulphide mineralization. 63.2-77.4 -Core is more highly broken mostly by drilling,very close to closely spaced throughout. 57.9-59.5 -Felsic dike,li9ht gray,no mafics, very hard. DESCRIPTIM :COLOR,TEXTURE,FOLIATION I JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS DR GAIN,CAVING,LOST CORE,CEMENTING,ETC 62.2-63.8 -Alteration zone,slightly to moderately hydrothermally altered,core slightly pitted,several healed fractures. Sulphide mineralization on fracture surfaces. 62.45 -Fracture,70 o _go o ,friable on surfaces,clayey. 62.75 -Possible shear.40°_50°,less than 0.12 inches wide,clay filling. 63.9-87.9 -Joints close to moderately clos~y spaced. 68.9-87.9 -Joints close to moderately closely spaced. 68.0-70.0 -Sulphides along most joints. ROCK TYPE Quartz Oi orite DEPTH (FT.) 70 (65.8) 60 (56.4) 80 (75.2) ;i;1 ~,~'!m ~1'1 .)'1 1 ! >1 C~J "~~~l -]"'·-'~l ].,~~]-~'-""-l ]J ~'~-'l """l ~l J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 PROJECT Sus itna Hydroe 1ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO,BH-l SHEET NO,5 OF 10 SITE Watana (North Bank) HOLE NO.BH-l SHEET NO,6 OF 10 Run 22 116.3 to 120.4-135.0 -Joints close to moderately close.h21.2 DEPTH (FT.) 120 (112.8) ROCI<TYPE Quartz Diorite DEseRIPrl ON:COLOR,TEXTURE,FOLIATION,JOI NTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REe (ROO) 100 (100) DEPTH (FTJ 150 (141.0) ROCK TYPE Quartz Diorite OESCRIPTI ON:COLOR,TEXTURE,FOLIATiON ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. 150.7-158.4 -Numerous fractures,joints closely spaced at 10°-20°to core axis,some broken by drilling,planar.Healed with carbonate and chlorite.Core loss 1.2 feet. LENGTH REGOFRUN (FT.)(ROD) --- --- Run 29 149.7 I 81 to (53) 155.9 123.5-123.75 -Alteration zone,slightly Run 23 bleached,slightly hydrothermally altered.121.2 100 Two joints at 30°and 50°with some clay/to (96) carbonate coating,slightly friable.126.1 125.0-125.8 -Healed breccia,quartz diorite Run 30 fragments in fine grained quartz diorite 159.7-174.2 -Shear/alteration zone,moderately 155.9 I 76 matrix. Run 24 to completely hydrothermally altered with l~~0 (55) 126.1-127.3 -Alteration zone,slightly 160 bleached,hydrothermally altered and 126.1 100 (150.4) localized shearing.. 130 i mineralized band,sulphide healed fractures,to (100)159.7-165.4 -Alteration zone,severely I tight,hard.131.0 to completely altered,core friable, (122.2)pitted,feldspars altered to clay.Very Run 31 l-----soft and plastic in upper 2.0 feet. Slickensides observed on soft clay coated 161.0 I 58 Run 25 remnant joint.Core loss 3.3 feet.to (0) 166.0 131.0 98 165.4-171.0 -Moderately hard to hard, to (98)bleached white,slightly friable along 135.8-174.2 -Core becoming more fractured. 1 136 . 0 fractures and joints. Joints generally very close to close spaced,Run 32 some drilling induced.Contains a few 171.0-174.2 -Completely hydrothermally healed fractures.altered as above,friable,soft and 166.0 I 100 Run 26 clayey,plastic.to (66) 136.0 100 170 173.6-174.2 -Quartz vein.171.0 to (80)(150.4) 141.0 174.0 -Partially healed shear or breccia ~----, 140 i I I zone,20°to core axis,0.5 inch wide.Run 33 (131.6)171.0 I 76 Run 27 I ,I 174.2-222.0 -Fresh and hard,joints very to (30) 1 close to moderately close spaced.176.0 141.0 100 to (100) 145.5-146.45 -Felsic dike,light gray,fine 145.5 f I Run 34 grained,less than 5%mafic minerals,hard.176.0 I 100 148.7-148.9 -Joints at 20°and 30°,Run 28 to (96) respectively,clayey material containing some 145.5 100 181.a rock fragments.Probably shear plane,no to (76)180 slickensides.149.7 (169.15 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NElli YORK DRILLING REPOAT CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project HOLE NO.BH-l SHEET NO.7 OF 10 CLIENT ALASKA POWER AUTHORITY P5700.05 BH-1 SHEET NO.B OF 10 JOB NO. HOLE NO. Watana (North Bank) PROJECT Susitna Hydroelectric Project SITE P5700.05JOBNO Watana (North Bank)SITE DEPTH (FT.)ROCK TYPE oEseR I PTI ON:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTl NG, Al.TERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REG (RQD) DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLlATION ,JOINTI NG,fRACTURING,FAULTI NG I ALTERATION,WATER LOSS OR GAl N,CAVI NG,LOST CORE,CEMENTING,E:TC LENGTH Of RUN (FT) REG (RQD) Run 44 211.0 L100to(76) 216.1 1------- 190 (178.5) Quartz Di orite Run 35 181.0 to 186.0 Run 36 186.0 to 191.0 Run 37 100 (100) 100 (100) 220 (206.7) Quartz Diorite 211.0-270.2 -Ori11ing water return less than 50%. 222.0-224.8 -Alteration zone,moderately to severely hydrothermally altered,feldspars altered to clay.Texture intact.Very friable. Run 45 216.1 to 221.0 Run 46 221.0 to 226.0 100 (82) 100 (51) IRun 44 211.0-1 100 216.1 (76) Run 42 204.8 100 to (64) 208.4 IJ<ui1'IT 208.4 I 92 to (92) 211 .0 191.0 to partially open 1196.0 and chlorite. 100 (94) 100 (78) 100 (100) Run 49 236.0 to 240.9 231.0 to 236.0 Run 47 226.0 to 231.0 close to moderately closel··--~I----­ Run 48 .--~--- Run 50 240.91 100 to (90) 246.0 223.5-224.8 -Alteration zone,moderately hydrothermally altered,cut throughout by irregular fractures and joints,primarily at 0°_10°and 40°.Carbonate healed but altered by hydrothermal solution.Penetrative up to 0.06 inches around fractures.Weakened but moderately hard. 224.8-243.0 -Joints spaced. 226.0-226.5 -Quartz vein,0.12 inches wide at 20°to core axis,0.75 inches wide alteration zone above it,moderately hydro- thermally altered.Moderately hard. 226.3-227.3 -Quartz stringer,0°_10°,0.12 inches to 0.25 inches wide. 227.7-228.2 -Mafic dike,aphanitic,20°, 0.5 inches wide,hard.Probably andesite. 232.8 -Shear,25°,less than 0.06 inch wide, hard.tight.Healed with carbonate.240 (225.5) 230 (216.1) 100 (70) 93 (73) 100 (92) Run 38 196.0 to 199.0 Run 39 199.0- 201.0 207.1-207.3 -Shear,30°,contains 0.13 inch wide brownish green calcareous clay with some small rock fragments,surrounding core hard. 207.6-208.3 -Shear,10°,0.06 inch wide, yellow-brown carbonate filling with small rock fragments.Surrounding core is hard. 195.6-196.6 -Joint at 0°_10°, with thin coating of carbonate and sand size rock fragments. 195.0-205.6 -Several closely spaced low angle joints 0°_15°.Most are tight with irregular surfaces,partially to completely coated with chlorite and carbonate. 210 (197.3) 200 (187.9) r}~~~,j n 1f l Si )J I I "I 1 ~~'~l ',.....)·~-"~l .~~].'~.."~J '~--,'-'}"']-'1 ""']']T"J J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-l SHEET NO.9 OF 10 SITE Watana (North Bank) HOLE NO.BH-1 SHEET NO.10 OF 10 REe [RQD) I..ENGTI-I OF RUN (H) Run 57 275.4 100 to (lOO) 280.4 -- Run 58 280.4 100 to (25) 285.6 -- Run 59 285.6 I 100to(82) 289.0 Run 60 289.0 I 83to(58) 295.0 DESCRIPTION;COLOR,TEXTURE,FOLIATiON ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. 282.5-284.7 -Alteration zone,severely hydro- thermally altered.very soft and friable,all feldspars altered to clay,texture partially preserved. 282.5-283.4 -Contains a thin aphanitic dike,0.38 inches wide,20°,sheared and brecciated but intact. 284.8-287.2 -Aphanitic dike.quartz rich, less than 5%mafics,very hard.Joints close at 10°and 45°,most have carbonate coating. Numerous healed,irregular fractures through- out. 290.2-292.0 -Fracture,0°_5°,healed with quartz,very tight,hard. ~Cl(TYPE Quartz Diorite DEPTH (FTJ 290 (272.5) 280 (263.1) Run 53 256.0 1100 to (94) 260.9 LENGTH I REeOFRUN (FT)[RQD) -- eLlI V.VU 1111;/1"~lIue,I Run 50 Run 51 246.0 1100 to (100) 251.0 Run 52 251.0 I 100 to (96) 256.0 DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVING,l.OST CORE,CEMENTING.ETC 256.0-299.9 -Core is very hard with close to moderately close spaced joints. 242.5 -Shear,30°,less th"~~r ~,,'-~L possibly broken by drilling.~onl;d"IS .nll' coating of calcareous clay material. 244.5-245.4 -Felsic dike,quartz rich,less than 2%mafics,very hard.Upper and lower contacts at 40°. 243.0-256.0 -Core is generally very hard. Cut by numerous fractures at 5°_20°,most are healed and tight,some broken by drilling. Contains thin coating of carbonate and chlorite.Fracture spacing close to moderately close spaced. ROCK TYPE Quartz Diorite DEPTH (FT.) 260 (244.3) 250 (234.9) 270 (253.7) 267.4-269.2 -Joint,5°,healed with carbonate. Run 54 260.91 100 to (100) 265.6 Run 55 265.61 100 to (80) 270.2 299.9 (281.8) 300 (281.9) END OF BORING R!~~100295.(82)to 298.8 -I1JU Run 62 (100) Run 5/ 270.21 96 to (96) 275.4 r--I I Run 5 ~~)~"~l ]'-"'1 /-"""-.-.."-~1 =~l ,.~,.::J ,..•.,}"-")--1 ---...._-]-J J Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG ALASKA POWER AUTHORITYClient Project Susitna Hydroelectric Pro~_ Site Watana~1:I1 Bank) Job No.__P5700.05 Hole No.~ Sheet No._1_of _1_ REMARKS END OF BORING 299.9' Shear/fracture/ alteration zone. Dike,felsic. Shear. Dike,felsic. Fracture zone. Breccia,healed. Fracture zone, altered. Dike,felsic. Fracture,healed. Shear,alteration zone. Shear/fracture zone Shea r. ROCK TYPE AOD % CORE RECOVERY % 28 26 24 ~~T~~I ~~~.~' 1----'-1--:--++++1-1 I I I I I I I I I I I I I I I ~bU rden I TOP OF ROCK 18.7 I Quartz Di orite • --~]"==-.,'---1 ~._~] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BU FFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLlE!'lT:ALASKA POWER AUTHORITY JOB !'lO"P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric ProjectPROJECT, SITE: Susitna Hydroelectric Project Watana (North Bank) HOLE !'lO,:BH-2 SHEET !'lO,1 OF'13 SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.2 OF 13 CONTRACTPR:The Drill ing Company LOGGED BY"K.J.White,M.P.Bruen Run 6 30.5 I 98 to (24) 35.5 LE.NGTH AEGOFRUN (FT)(ROD) -- Run 3 19.8 I 100 to (58) 25.0 RU.n::! Run 5 25.5 I 100 to (58) 30.5 DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOiNTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 15.8-16.9 -Core badly broken by drilling, angular fragments 0.5 to 1.0 inches,carbonate filling and iron oxide staining. 23.4-26.1 -Joints very close to closely spaced. 25.7 -Joint,30°,trace of clay. 26.1-30.9 -Joints closely spaced. 29.4 -Fracture,50°,clay coating. 30.9-48.25 -Joints very close to closely spaced. ROCK TYPE Andesite Porphyry DEPTH (FTJ I 30 "24.6) % 'EO (RQO) A.S.P.C.,Zone 4 1838.8 1830.6 1510.3 1768.8 (7-28-80) CASI!'lG DIAMETER:NW (3.0")I.D. CORE DIAMETER:NO (1.75")0.0. DRILLI!'lG DATES:JUly 14 TO July 27,1980 DATE:July 1981 OEseRI PTION,COLOR ,TEXTURE,FOLIATION,JOINTING,FRACTURING l FAULTING,I 'UN ALTERATION.WATER LOSS OR GAIN,CAVING I LOST CORE,CEMENTING,ETC.LENGTH Casin~Advancer Diamond Core -Triple Tube N3,227,725 E742,040 043 0 55° LATITUDE DEPARTURE AZIMUTH DIP SOILROCK ELEVATIONS,DATUM MSL, GROUND SURFACE ROCK SURFACE BOTTOM OF HOLE WATER TABLE Depths measured along hole.True depths in (). All angles measured to the core axis. ROCK TYPE Overburden DRILLI!'lGt.lETHOD: o NOTES,1) 2) DEPTH (f't) LOCATION: Run 7 35.5100 to (92) 40.5 96 (53) Run 9 45.7 100 to (77) 50.5 Run 10 50.5-1 100 55.7 (8l) Run 8 40.5 to 45.7 I-I 51.0 -Flow structure.50°. 51.65-55.9 -Joints very close to moderately close spaced. 50 (41.0) H 401\32.8) 100 (57) 100 (46) Run 1 10.0 to 15.0 February 1,1982DATE: TOP OF ROCK I GreeniS\l9ray to medlum gray,hne gralnea- groundmass with fine to medium grained white plagioclase phenocrysts.Flow structures. Contains inclusions of a gray-White,medium grained diorite,a green,very fine grained andesite,and possibly some argillite. Inclusions are generally less than 0.75 inches in diameter.Generally hard,fresh to slightly~----~-----+ weathered.Joints are iron stained,some R 2 carbonate filling.Disseminated sulphides un throughout.15.0 10.0-23.4 -Joints closely spaced.1~~7 15.8-16.9 -Core badly broken by drilling, angular fragments 0.5 to 1.0 inches,carbonate Run 2A 82 45 fillin~~~d iron oxide staining.Run 3 vl;lo4f~ Andes1te Porphyry APPROVED, 20 (16.4) 10 (8.2) // ACRES AM£RICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Wa tana (North Ban k) HOLE NO.BH-2 SHEET NO.3 OF 13 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.4 OF 13 DEPTH (IT)FlOCK TVPE DESCRI·PTION :COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAV1NG,LOST CORE.CEMENTING I nc LENGTH REe O~F~YN (ROD) DEPTH IFTI ROCK TYPE Qf:SCAIPTI ON;COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,fAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH DF RUN (H) REG (ROD) I Run Run 20 81.0 I 97 to (34) 84.5 3 (0) 18 (0) 75 (0) 77 (0) 67 (0) <9 (0) Run 23 90.2- 92.0 Run 24 92.0 to 95.0 Run 25 Run 29 101.8 to 108.0 Run 31 109.6 to 115.2 Run 22 85.0 I 77to 90.2 (51) Run 321 fj 115.2-(0) 118.2 ~-30hg-1 108.0-1 (oj 109.6 100 I-Run 261 (U--1 (0) Run 27 97.8 to 100.1 IRuil28 100.1- 101.8 109.6-118.2 Shear/alteration lone,bleached chalky white breccia and 90uge,slightly to severely altered hydrothermally throughout, soft,friable,slickensides.Thin gray clay layer at 20°to 50°. Core loss 2.2 feet. 114.8-118.2 Slightly to moderately altered hydrothermally,bleached.Joints at 20°to 40°,healed fractures and joints throu9hout. Core loss 0.8 feet. 81.9-82.3 Rubble 83.1-85.0 Fracture lone,joints very closely spaced at 30°to 60°,some are healed.Some iron oxide stainin9 and carbonate fillin9· 88.0-109.6 Shear/fracture zone,joints close to very close spaced at 20°to 80°,with iron oxide staining,carbonate coatin9 and clay gouge,sl ickensides.Core badly broken.Core los s 11.8 feet. Andes ite Porphyry 110(90.1 ) 100 (81.9) 90 (73.7)55.7 1100 to (55) 60.8 Run 11 Run 12 60.8-1 76 63.7 (38) Run 1(j 50.5 1100 to (81) 55.7 Run 13 63.7 I 88 to (28) 66.9 80.8-81.1 -Fracture zone,joints very closely spaced at 40°to 70°,iron oxide staining. 53.05 -Joint,30°,leis than 0.1 inch wide, rough,irregular,clay coating. 55.7-60.8 -Core loss 0.7 feet. Run 14 66.9-95 69.7-70.5 -Fracture zone,joints very closely ~~~~UJ-~ spaced,3D·and 60·orientation.Some Run 15 fractures healed,carbonate filling,some iron 68.9-100 staining.71.2 (65) 71.2-177.1 -Shear/fracture zone,joints very Run 16 100--0- closely spaced,fracture zones of gouge and breccia.Hole caving,core badly ground in Run 17 places,grouted.Core loss greater than 20.6 72.0 20 feet.to (0) 71.2-79.6 -Fracture zone,joints very closely 1~7~5~.~5~--4 spaced at 20·to 60·,fresh to slightly Run 18 weathered.Clay and carbonate filling,75.5-15 rounded to subangular pieces less than 0.2 7.5 (01 feet.Core loss 5.9 feet.Run 19 77.5 I 57 to (11) 81.0 57.65-70.45 -Joints very close to closely spaced. 64.3 -Joint,3D·,irregular,smooth, slickensides. Andesite Porphyry 80 (65.5) 70 (57.3) 60(49.ij) 1 ;1 ]J 7 ~~ JI '~--=~1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT 1 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.5 OF 13 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.6 OF 13 DEPTH ROCK TYPE DESCRIPTION:COLOR,TExTURE,FOUATION,.JOINTING,FRACTURING,FAULTI NG,~iN~~~REC DEPTH ROCK HPE OESCRIPTION:COLOR,TEXTURE,FOUATlON,JOINTI NG,FRACTURING,FAULTI NG,LENGTH RlOe (FTJ ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.1Ft)(ROD)(FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTI NG,ETC °fF~~N (ROD) 118.2 AnaeSl Le Run 32 /3 '". 1.196.8)Porphyry (0)150 Ulonte Run 42 22 Andesite Very thin to thin layers of green,medium Run 33 (122.9)148.0-(0) and grained crystalline rock and greenish gray,118.2 79 ~ 120 10iorite aphanitic igneous rock.Slightly altered to (29)Run 43 1 48 (98.3)(Transitional hydrothermally,joints very close to closely 121.0 151.0 (0) Zone)spaced,iron oxide stained,penetrative to to 0.5 inch,carbonate coated,hard.~ 122.5-123.7 Fracture zone,broken by drilling.~u~34 87 Run 44 80 Core loss 0.7 feet.2.0 (51)153.7-(0) to l-1~5",5-,-.7~__ 125.71 b 125.7 Run 45 60 (103.0),.155.7-(0) Oiorite Green,medium 9rained,20-30%mafics (biotite Run 35 78 ~~~'~61 and hornblende).Generally moderately hard,125.7 (78)158 2 1 fresh to slightly altered hydrothermally.to 160 to'46 Joints very close to closely spaced,iron 28.4 131.1)60 8 (15) stained,some carbonate coating and sulfide Run 36 '...~ mineralization.28.4 92 63:5-170.5 JOlnts ~lo~ely spaced,Hon oXlde un I 75 (11gg.5)1 1125.7-128.4 Core loss 0.6 feet.to (46)talned,carbonate fllllng.1~~:~-(0) ~134.2-135.3 Fracture zone,joints very Run 37 closely spaced at 20°and 60°.131.0 I 89 I [1 I IRun 48 1 90134.9-137.7 Healed breccia,70%diorite to (0)162.8 fragments up to 2 inches in diameter in a 34.8 to (43) matrix of dark green fine grained diorite.167.9 Hard,sharp contacts. Run 38 I Run 49 134.8 94 167.9-1 100 to (70)170 170 5 (88) 139.8 139.3)170.5-172.3 Fracture/alteration zone,s~ightlY . 139.6-141.8 Fracture zone,joints very close to moderately altered hy~rot~erma~ly,JOlnts to closely spaced at 200 to 30°.very closely spaced at 0 -10 ,.frlable,core 140 -l 1Core loss 0.7 ft:Run 39 badly broken.Feldspars altenng to.clay.I Run 50 (114.7)1 139.8 81 ore loss 0.8 ft.170.51 94 143.1-163.5 Shear/fracture zone,joints very to (0)to closely spaced at 0°to 60°,some slickensides.41.\0 bll 17Q.8 (42) Breccia and clay gouge,some carbonate,friable ~~~9 (52) locally,pieces less than 0.1 feet.Core . badly broken,core loss 10.3 feet.to j l j ~~§~ll 67 144.4-148.0 Triconed,no core recovered.~~~·~l.177:0 (0) 144.4 ncone Run 52 to 177.0 I 90 148.0 180 to (73) Run 42 147.4)181.0 ACRES AMERiCAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SH EET NO.7 OF 13 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.8 OF 13 DEseRI PTI ON:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG I ~~N~~I REC ALTERATION,WATER LOSS OR GAIN 1 CAVI NG,LOST CORE,CEMENTI NG,ETC.(Fll (ROD) DEPTI-I (FT) 190 (155.6) ROCK TYPE Diorite 177.1-197.3 Diorite is generally hard to very hard.Joints are moderately close spaced. 179.65-179.8 Ap1itic dike,gray-white,fine grained,less than 10%mafics.Welded sharp contacts,oriented at 40°. 186.5-187.1,191.2-191.7 Ap1itic dikes,gray- white,fine grained,less than 10%ITIafics. Unfractured,welded contacts at 30°and 75°, sharp. 191.0-196.4 Core loss 0.7 feet. [RUil-S11 100 181.0-(100) 182.8 Run 54/100182.8 to (100) 186.7 Run 55 100 186.7-(100) 189.0 Run 56 189.0-1 100J.2l.Q--!-(1 00 ) DEPTH (FTJ 220 (180.2) ROCK TYPE Diorite [mRIPTI ON:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAUI..TI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 208.6-209.2 Core badly broken,fragments generally less than 1.0 in.,clay on most joints,pieces of breccia and gouge. 209.7-237.1 Joints generally very close to close spaced,15°to 80°,iron oxide stained, some carbonate filling. 213.8-245.8 Generally hard and fresh.Joints are iron stained,some calcite filling. 214.4-218.5 Core loss 0.3 feet. 223.2-223.6 Core loss 0.4 feet. ~~Ng3~I REC (FT)(RQO) Run 6 Run 6l 100214.4 to (76) 218.5 Run 61 218.5\92to 223.7 (77) 1---+---1 Run;,228.7 100 to (68) ~_.5 100 (85) 200(163.8) 210 (172.0) 195.2-209.3 Shear/alteration zone,slightly altered hydrothermally,gouge material. 195.2-197.4 Breccia,white rock,iron oxide staining,feldspars of diorite bordering this zone are altering to clay minerals.Very soft, friable.Core loss 0.4 feet. 204.6-209.2 Shear zone,joints very closely spaced,moderately intense iron oxide on 20° joints,minor chlorite with clay coating.Core badly broken throughout,core loss 0.4 ft. 204.6 Joint at 80°,0.25 inches wide,gray clay 205.3-205.7 Breccia/gouge,core badly broken. 207.1-207.4 Core broken,clay on joints. 208.3-208.5 Irregular,dicontinuous vein of carbonate with sulfide mineralization. Run 57 191.0 to 196.4 Run 58 196.4 to 201.0 Run 59 201.0 to 203.8 Run 60 203.8 to 207.1 Run 61 207.1- 209.3 Run 62 209.3 to 214.4 80 (59) 91 (37) 100 (32) 100 (15) 91 (0) 100 (49) 230 (188.4) 240 (196.6) 237.1-237.7 Fracture/alteration zone,bleached slightly altered hydrothermally,increase in sulfides near joints.Joints very close spaced at 60°_70°. 241.3-262.0 Shear/alteration zone,moderately to severely altered hydrothermally,highly fractured.Breccia lone,several zones of soft,friable rock,clay gouge,polished surfaces with faint slickensides.Joints very close to close spaced at 20°and 50°,iron stained,with clay on most joints.Carbonate veins and coating. Run 6 223.7 to 228.7 Run 6 232.5 to 237.7 Run 6~ 237.7 to 241.9 Run 6 241.9 to 247.2 100 (66) 100 (57) 87 (0) ~~1 '~1\,8 ~?~.11 &.~ --l '--'~-I '-~.J r~---,~~-J ~-'~'~l .-c"~~l F C .' ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5 700.05 PROJECT Susitna Hydroelectric Project SITE I~atana (North Bank) HOLE NO.BH-2 SHEET NO.9 OF 13 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.10 Of 13 DEPTH I DESCRIPTION;COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULT!NG,LENGTH REC DEPTH ROCK TYPE OF RUN I ROCK nPE(FT.J ALTERATION,WATER LOSS OR GAIN,CAVING,LOST COREl CEMENTING,ETC.(Ft)(RQD)(FT.) Olorne 247.0-248.6 Brecclated and clay gouge,Run 69 77. irreqular fractures and carbonate fillina.227.6)1245.8 Andesite t?)ILight to medlum green ,aphanitic to fine ground Diorite (201.3)mass,fine and medium grained white phenocrysts of feldspar,less than 10%mafics,primarily I I ~280hasaporphyritictexture,Contains inclusions Run 70 100 (229.4) of the gray-white diorite and a very fine 247.2 (0)250 i Igrained mafic rock.Possible flow structure.to (204.8)Upper contact in brecciated zone assumed to be 252.2 fairly sharp.Joints very close to closely spaced,most carbonate caated,some iron oxide staining.[Note:Resembles both andesite and diorite in places due to variations in grain IRun 71 1 100size.]252.2 to (49) 257.4 Run 72 1 100257.4 (28)to 262.2 Run 73 262.2 1 100 to (41) 265.0 Run 74 265.0 I 100 to )269.0 (50 Run 75 269.0-1 100 271.0 (l00) 96 (48) LENGTH I REC OF RUN (RQD)(FT.) Run 7 285.81 90 287.8 (0) Run 7< 280.61 96to 285.8 (61) Run 7 276.1 I 89to 280.6 (58) Run 841100 306.1-(90) 310.2 Run 81 291.1 to 296.1 Run 83 301.1 1 100 to 306.1 (62) Run 82 296.1 1 100 to 301.1 (80) DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 288.2-289.3 Healed shear,15°-30°,healed with dark green fine grained diorite.Run 80 287.8 100 290.7-293.1 Joints very close to closely I.!?(88) spaced,oriented at 15°ta 70°.Iran staining ~~l-+-~ and carbonate filling. 300.9-301.2 Fracture zone,joints very closely spaced,oriented at 40°to 70°.Clay filling and chlarite coating. 301.1-306.1 Core loss 0.4 ~t. 301.2-328.0 Joints close to moderately close spaced,oriented at 0°to 70°chlorite and carbonate filling.Hard and fresh. 285.8-287.8 Fracture zone,joints very close to closely spaced,ariented at 20°to 60°, carbonate present.Hard and fresh.Core loss 0.1 ft. Gray-white to gray-green,medium grained rock, 20-30%mafics.Generally very hard and fresh. Joints are closely spaced,some carbonate filling,iron stained,and/or calcite filled. 300 (245.7) 290 (237.6) 100 (84) Run 77 Run 76 271.0 to 276.1 277.7 Lower contact,oriented at 20°,sharp contact of andesite and diorite,single joint with thin clay seam.Rock is fresh and hard on both sides. 270 (221.2) 260 (213.0) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE vJatana (North Bonk) HOLE NO.BH-2 SHEET NO.11 OF 13 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-2 SHEET NO.12 OF 13 DEPTH I ROCI<TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG,I LEN~0~REC DEPTH ROCK TYPE DESCRIPTION:COLOR,TExTURE:,FOLIATION,JOINTI NG,FRACTURING,FAULTl NG, (FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.O~~l (ROD)(FT.l ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTI NG,ETC. I Run 84 iorite 0 310 j D''t(253.9)lOrl e I Run 93Run85 I 100310.2 92 341.4 (100)345.8-348.5 Alteration lone,slightly alteredto(54 )hydrothermally,joints have a thin clay to 315.4 coating/fillin~.Several healed fractures,346.6 moderately hard.-~----~-I Run 94 Run 86 346.6 I 98 315.4 to (77) to 100 350 351.0 320.4 (86)(286.7)-----i----- 320 1 E21.2-321.4 Shear,breccia and gouge,clay with I Run 95 (292.1)ome carbonate filling,iron oxide staining.351.0 I 100 Run 87 to (88) 320.4 100 356.0 to (52)~25.1 Joint,40°,slickensides.C25 .3 -~ .J---.____ Run 96 94 Run 88 356.0 I 325.3-100 to (95) 128.0-335.9 Joi""010"to ""0'0"",p.o,d 328.0 (63)361.0 360enerallyorientedat30°to 50 0 ,carbonate (294.9)361.0-366.0 Core loss 0.8 ft. ill ing.Run 89 362.0 Amount of mafics increase from 20-30%~------+--- 330 ~328.0 98 to 30-40%. (270.3)to 362.5-363.5 Felsic Dike,light gray,hard,I Run 97 1 90332.4 (43)unfractured,tight contact,oriented at 10°,361.00.5 in.wide.to (90) I I I 366.0 Run 90 I ~35.9-372.0 Joints close to moderately close 13i~'4 1100 I I I I paced,carbonate and chlorite.Run 98 337.5 (75)366.0 1 100 to (91) 370.6 Run 91 I I [370 j 1370.3-381.0 Carbonate in joints. 337.5 97 (303.1)1991100to(81)340 ~I I 341.0 (87) 11278.5) 1-~1 "q ~~1 -]1 ']-~~~\'J 1 ~~ J :J 0 -\I j ~-I .---.--,~----J --1 ~1 ~~-.,-")."'=j -1 -I ::-~':i --1 I ·---1 1 j ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE \,atana (North Bank) HOLE NO.BH-2 SHEET NO.13 OF 13 DEPTH (FTJ ROCK TIPE DE:SCRIPTlON:COLOR,TEXTURE:,FOL1AT10N,JOINTING,FRACTURING.FAULTING, ALTERATION,WATER LOSS OR GAIN ,CAViNG,LOST CORE,CEMENTING I ETC LENGTH OF RUN (FT.) REG (ROD) 96 (67) Diorite 374.1-375.0 Iron oxide staining. Run 9 370.6~00to(87) ~8 ___ Run 10C 375.8 to 381.0 96 (59) Run 10 381.0 I 96to 386.2 (51) Run 1:02 386.2 100 to (87)391.2 380 (311.3) 390 (319.5) 382.0-392.6 Shear/alteration zone,sl ightly tol I I moderately altered.Joints are very close to close spaced,filled with carbonate and iron oxide staining,clay gouge,and sulfide mineralization. 382.0 Joint,oriented at 70',0.1 in.wide black clay layer in a carbonate vein 0.5 in. wide. 383.5 Shear,oriented at 40',0.5 in.wide, breccia,soft and friable.Carbonate filling with iron oxide staining. 386.2-386.8 Shear zone,chalky white clay gouge,iron oxide stained breccia.Soft, friable. 392.6-401.0 Joints very close to close spaced,t----t------- numerous healed joints throu9hout,hard.Run 103 I 391.2 to 396.3 Run 1041 393.3- 398.8 96 (38) 400 J I IRun 1051. TIlO [uii.7J1--------+--END OF BORING _+------+l~ 401.0 . (328.5} "~)~1 "'-'-'1 C"'""]----1 "1 ----1 ~-"-~~1 J~l '=CC'=]-)':~'1 J "'--j ,--1 Acres American Incorporated -Consulting Engineers Buffalo,New York Job No.P5700.05 Hole No.,_-"B"-'H"'-2=--_ Sheet No._1_of 2 SUMMARY LOG Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client AI ASKA POWER AliTHOR TTY Job No.__P5700.05__ Project Susitna Hydroelectric Project Hole No.BH-2 Site Watana (North Bank)Sheet No._2_of __2_ PER MEA BIUTY CORE RECOVERY ROO NUMBER OF DEPTH ELEV,(K)em /IOC %%JOINTS PER ROCK TYPE REMARKS(FT.)(FTJ 10 FT. 10 6 10-4 10-2 20 40 60 80 20 40 60 eo 5 10 15 2.0 360 Diorite 380 '----e--"]Fracture/alteration 400 ~511 " zone. END OF BORING 401.0' e------e--- 1------ ----- e------t----,~- I----- f-- C---_ I------ e---e----f--"---- 1 -f---- e------- -f---- --'----"- ---~- ~-- ---'- ---e----- ---"~----,-- 'r'-"-j" --e- " l-- • _IOP_O.LRllflLlQ.JJ~__ REMARKS :::t Shear. I::]Shear. 'J Shear/fracture zone Fracture/alteration zone. ,]Fracture zone. 11 Frac tu re zone. dShear/alteration zone. ROCK TYPE Client ALASKA POWER AUTHORITY Project __Susitna Hydroel ectri c Proj ect Site Watana (North Sank) DEPTH IREV.I ,~,·n,~~........I CORE ~1COVER'r'I ROD (FT.){FT.}(KJ cm/8IIc.% 0 20 40 60 80 i 00 ~-;57 120 - 140----t 1716 160 180 200 220 240 ---+1634 260 2S0 :o~l593 320 340 ---]1 --]"'1 c'....]1 .-'1 .--]-1 ......J ---]1 "-1 J )-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT:ALASKA POWER AUTHORITY JOB NO.,P5700.05 CLIENT Al aska Power Authority JOB NO.P570l.05 PROJECT,Susitna Hydroel ectri c Proj ect HOLE NO.,BH-3 PROJECT Susitna Hydroelectric Project HOL E NO.BH-3 SITE:Watana (North Bank)SHEET NO.1 OF 31 SITE Watana (North Bank)SHEET NO.2 OF 31 CONTRACT(jR:Interstate Exploration Inc. LOGGED BY·.K.J.White,M.P.Bruen REO (ROD) LE:.NGTH OF RUN (FT.) DESCRIPTION;COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. Overburden RCCIo<TYPEDEPTH (FT.) CASING DIAMETER:NW (3.0")J.D. CORE DIAMETER,NO (1.75")0.0. A.S.P.C.,Zone 4 2150.7 2124.7 1367.8 DRILLING DATES,.August 15 TO September 9,1981 DATE,September 1981 Cas i ng Advancer Diamond Core -Triple Tube N3,228,197 E744,103 338 0 55 0 LATITUDE DEPARTURE AZIMUTH DIP SOIL ROCK ELEVATIONS:DATUM MSL, GROUND SURFACE ROCK SURFACE BOTTOM OF HOLE WATER TABLE Depths measured along hole.True depths in (). All angles measured to the core axis. DRILLING METHOD, LOCATION: NOTES,1) 2) (/!£JlIR!i DESCRIPTION,COLOR ,TEXTURE,FOLIATION,JOINTING,fRACTURING,FAULTING,I RUN ALTERATION.WATER LOSS OR GAIN.CAVING I LOST CORE I CEMENTING,ETC.LENGTH 100 (44) 100 (40) 100 (98) to to 36.7 40.7 Run 6 Run 3 100 40.7 (37) to 45.8 Kun 1D1T (36) Run 5 100 46.9 (97) to 50.8 TOP OF ROCK Medium gray-green,medium grained,less than 5~Run I quartz.Joints generally close to moderately I 31.7 closely spaced,iron oxide staining near sur- face,most joints carbonate coated.Fresh, very hard to hard. 31.8-46.4 Joints close to very closely spaced. Iron oxide staining on 30-40%of joints,trace ~I I to coating of carbonate.Run 2 36.7 Felsic dike,light gray,fine to medium 36 7 grained,10-20%quartz,less than 5%mafics,. 0.5 in.to 1.5 in.w~de.Tight contacts, hard,oriented at 90 . 41.8-42.2 Core broken by drilling,pieces 0.5 in.to 2.0 in.,iron oxide stained rock fragments. 43.4-43.7 Core broken by drilling,iron oxide staining gn fragments. 44.5 Joint,30 ,0.25 inch of carbonate fill ing. Diorite 50 (41.0) 3T.7 (26.0) 30 (24.6) 40 (32.8) % REC {RQol February I,1982DATE: /// No samples taken. ROCK TYPE Overburden DEPTH (FT.) APPROVED: a 20 (16.4) 10 (8.2) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT PROJECT Susitna Hydroelectric Project CLIENT Alaska Power Authority PROJECT SUS itna Hydroel ectri c Proj ect JOB NO.P570l.05 HOLE NO.BH-3 CLIENT Alaska Power Authority JOB NO.P570l.05 HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.3 OF 31 SITE Watana (North Bank)SHEET NO.4 OF 31 (100) LENGTH I RECOFRUN (FT)(RQD) -- Run 12 ;a~ 85.9 (98) to 90.8 -- Run 141 100 90.8 (84) to 95.8 95.8 to 100.8 Run 161100 100.8 (100) to 106.0 ~jst-TOO- DESCRIPTION:COLOR,TEXTURE,FOL.IATION ,JOI NTlNG,FRACTURING,FAuLTI NG, ALTERATION,WATER l.OSS QR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 69.2 Inclusion of dark green,fine grained diorite. 69.5-72.8 Occasional patches of red stain, irregular and discontinuous. 79.6-79.8 Core broken by drilling,pieces 1.0 inch to 2.0 inches. 80.B-80.9 Red staining on the core. 81.3-82.3 Joints,20°_30°,possibly open, iron oxide staining and carbonate coating. 81.3-B7.0 Diorite breccia,healed,hard. 85.7-93.8 Joints/fractures,closely spaced, up to 2.0 inches wide.healed with carbonate. 106.4-106.7 Red stain in core,covering 70%of zone. 94.1-95.1 Pods of felsic rock,light gray, fine to medium grained,some have quartz centers,up to 0.5 inches wide.Less than 5% of rock. 96.6-98.5 Joints,very close to closely spaced,healed with carbonate. ROCK lYPE Diorite DEPTH 1FT} 90 (73.7) 100 (81.9) REC (RQD) 98 (79) 100 (94) 100 (98) 100 (80) 100 (92) to 70.7 LENGTH OF RUN 1FT.) Run 10 70.7 Run 9 65.7 Run 8 60.7 to 65.7 DESCR\PTION :COLOR,TEXTURE.,FOUATION I JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER L.ClSS OR GAIN,CAVI NG,LOST CORE,CEMENTING 1 Erc 46.0-46.4 Shears,two along joints at 40°,Run 6 approximately 0.1 foot and 0.05 feet wide,50.8 breccia and gouge.to 46.4-111.2 Joints close to moderately closely 55.8~~ spaced,trace to coating of carbonate and Run 7 chlorite 55 8 46.B-48.4 Joints 20'to 30°,closely spaced,. healed with carbonate.to 49.4-50.2 Numerous irregular fractures healed 60 7 with carbonate,very closely spaced.. 52.3 Felsic dike,30°,unfractured,0.25 inch wide.tight. 52.4-53.1 Fracture zone,irregular,discon- tinuous,healed with carbonate,very closely spaced joints. 53.3-58.0 Healed diorite breccia,subrounded fragments of diorite to 2 inch,healed with dark green diorite. 57.5-57.9 Fracture zone,fractures less than 0.1 inch wide,very closely spaced,irregular and discontinuous,healed with carbonate. 61.2,64.3 Inclusion of dark green fine grained diorite,1.0 inch and 2.0 inches respectivelY. 65.9-69.9 Fractures,irre9ular and discon- tinuous,filled with carbonate,less than 0.1 inch to 0.25 inch wide,10%of rock. ROCK TYPE Diorite DEPTH (FT) 60 (49.1 ) 70 (57.3) Run 19 111.6-132.0 Diorite breccia,rounded to sub-I Run 18 angular rock fragments to 1.0 inch,60-70%110 7 of rock,in a dark green diorite matrix.Hard.. to 115.9 80 (65.5) 67.7-75.9 Healed breccia,contains fragments of diorite in the dark green,fine grained diorite.Fragments,70-80%of rock. to 75.9 Run 11 75.9 to BO.9 Run 12 80.9 to 85.9 9B (68) 98 (B4) 110 (90.1 ) 111.2-190.7 Joints moderately closely spaced, with zones of closely,spaced joints. Run 17 106.0 to 11 O.7 100 (100) 100 (100) 1 ~~"1)]~'1 •1il ]7!, J i ·1 J -~1 ~! .,-·---~-1 ----1 1 ~~J ---]~)1 ---J --~]1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT Alaska Power Authority PROJECT Sus itna Hydroel ectri c Proj ect JOB NO.P5701.05 HOLE NO.BH-3 CLIENT A1 as ka Power Authority PROJECT Susitna Hydroelectric Project JOB NO.P5701.05 HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.5 OF 31 SITE Watana (North Bank)SHEET NO.6 OF 31 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR I TEXTURE,FOLIATION ,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER L.OSS OR GAIN,CAVING,LOST COREl CEMENTING.ETC LENGTH OF RUN (FT.) REC (ROD) DEPTH (FT,)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLlATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION.WATER LaSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. LENGTH OF RUN 1FT.) REC (RQD) Run 251 100 (100) Run 261100 150.7 (100) to 155.7 Run 271100 155.7 (100) to 160.7 165.7 Run 301100 170.7 (94) to Run 31 175.7 to 180.7 Run 291100 165.7 (98) to 170.7 Run 281100 160.7 (100) to 175.7 1 100 (98) 153.0,154.0 Felsic dikes,light gray and light red-gray,10°and 15°,respectively, 0.5 inch wide.Second dike is offset D.25 inch along a joint at 50°,healed with carbonate,hard. 165.2 Alteration zone,hydrothermally altered,0.5 inch wide,feldspars breaking down to clay.No definitive contacts. Note:Zones of alteration within the healed breccia up to 6.0 inch wide,generally less than 1.0 foot to 2.0 feet apart moderately hard.Up to 25%of feldspars altering to clay. 177.0,177.2 Shear,20°;0.25 inch wide, healed with green igneous rock and carbonate. 153.9 Felsic dike,1ight red-gray,fine grained,at 10°.Truncated by shear at 30°, healed with dark green iqneous material and carbonate,with offset greater than 2.0 inches. 156.0 Carbonate vein,possibly a healed shear at 25°,0.25 inch thick.Carbonate is stained red. 157.0 Alteration zone,moderately altered hydrothermally,approximately 1.0 inch wide at 25°. 157.3-174.6 Healed breccia,angular fine grained fragments to 0.25 inch in an igneous groundmass,hard.Majority of fragments in breccia are dark gray to green subangular, fine grained,igneous rock. Di orite 180 147.4) 150 (122.9) 160 (131.1) 170 (139.3) 98 (50) 100 (100) 100 (100) 100 (100) 100 (100) to Run 201100 120.7 (100) to 125.7 Run 191 100 115.g (1 DO) to 120.7 Run 25 145.8 to 150.7 130.7 Run 21 125.7 Run 24 140.7 to 145.8 Run 23 135.7 to 140.7 Run 22 130.7 to 135.7 127.0-133.6 Shear/alteration zone,bleached to a light green,slightly altered hydro- thermally,hard. 127.7 Shear,15°,slickensides on carbonate, trace amounts of gouge. 128.9-135.7 Fracture zone,healed with car- bonate,close1y spaced up to 0.5 inch but generally less than 0.1 inch. 140.2-143.4 Fracture zone,closely spaced, irregular,and discontinuous joints healed with carbonate fill ing 1ess than 0.1 inch wide. 149.0-152.0 Alteration zone,slightly altered hydrothermally,feldspars altering to clay,hard. 135.7-138.3 Shear/alteration zone,slightly to moderately altered hydrothermally,oriented f---I I along healed shear to 10°.Feldspars breaking down to clay,approximately 1.0 inch wide. Moderately hard to soft.Core badly broken by drill ing. 137.9-138.3 Silty-sand coating,possible gouge. 116.7-126.7 Joints,close to moderately closely spaced,healed with carbonate up to 0.25 inch wide,irregular and discontinuous. 146.0-149.0 Joints healed with carbonate. Di orite 120 (98:3) 140 (114.7) 130 (106.5) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK BUFFALO,NEW YORK DRILLING REPORT DRILLING REPORT CLIENT Alaska Power Authority JOB NO.P570l.05 CLIENT Alaska Power Authority JOB NO.P5701.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-3 PROJECT Susitna Hydroelectric Project HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.7 OF 31 SITE Watana (North Bank)SHEET NO.8 OF 31 DEPTH (fT)ROC\(TYPE DEseRI PTI ON;COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST COREl CEMENTING I ETC LENGTH OF RUN (FTJ REC (ROD] DEPTH (FT.]ROCl<TYPE DESCRI prl ON;COLOR,TEXTURE,FOLIATION ,JOINTI NG,FRACTURING,FAULTl NG, ALTERAT\ON,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.) REC (RQD) Run 381 100 (100) 190 (155.6) 200 (163.8) 210 (172.0) Diorite 178.9 Joint,20°,possible iron oxide stain- ing.Alteration of feldspars on either side to 0.5 inches. 180.7-190.7 Joints closely spaced,approxi- mately 50%are carbonate healed,with chlorite coating. 184.4-184.7 Core is badly broken,pieces less than 0.5 inches.Friable,possible fracture zone or shear zone. 184.8 Fracture,0°,carbonate filled,offset approximately 0.5 inches. 186.3 Joints,two,40°and 90°,with sandy- silt coatin9. 188.0-190.3 Shear/fracture zone along joint at 0°to 10°,joints very closely spaced. Approximately 0.1 to 0.25 inches of gouge, no slickensides.Some are partially healed with carbonate and chlorite. 190.3-191.6 Healed breccia,50-60%rock frag- ments within a dark green diorite matrix, hard. 190.7-228.6 Joints moderately close to widely spaced,averaging 2-3 feet,most healed with carbonate. 190.7-195.0 Irregular patches of red stain. 203.0-203.5 Diorite breccia,healed with carbonate. 206.1-206.2 Healed breccia,70°,hard. Run 32 180.7 to 185.4 Run 33 185.4 to 190.7 Run 34 190.7 to 195.6 Run 35 195.6 to 200.7 Run 36 200.7 to 205.7 Run 37 205.7 to 210.7 100 (87) 98 (89) 100 (100) 100 (94) 100 (100) 100 (100) 220 (180.2) 230 (188.4) 240 I(196.6) Diorite 214.5-215.1 Numerous fractures,irregular and discontinuous,healed with carbonate up to 0.25 inches wide. 218.3-219.4 Healed breccia,approximately 50-60%rock fragments to 2 inches in a fine grained diorite matrix. 224.1-225.5 Fracture zone,fractures/joints very closely spaced at 00 to 20°and 50°to 70°.Healed with carbonate,tight. 228.6-228.8 Core broken by drilling (7), angular pieces,0.25 to 0.5 inches,carbonate coating. 228.6-315.7 Joints moderately closely spaced (average 1.0 to 2.0 feet).Approximately 50%healed with carbonate. 230.5 Felsic dike,fractured but tight,at 20°,0.5 inches wide. 233.3 Healed shear,10°,1.0 inch wide brecci~ zone,fragments of breccia are predominately carbonate,matrix is dark green igneous material.Re-shearing along this zone,silt and clay costing. 236.4 Healed shear,20 0 ,0.25 inches wide, hard. 239.6 Joint,20°,trace to 0.25 inches wide, tight. 241.3 Shear,10°,0.5 inches wide,healed with carbonate,ti9ht. Run 381100 210.7 (100) 2l5?7 Run 391100 215.7 (100) to 220.7 Run 401100 220.7 (100) to 225.8 Run 411100 225.8 (100) to 230.8 Run 421100 230.8 (100) to 235.9 Run 431100 235.9 (96) to 240.9 Run 441 100 240.9 to 245.9 1(100) Jj '1 .~~!l ~j jj 1 , J .'jJ -,~".]1 c·~l ·'1 ·~l ....J ")._]'-1 1 ·-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT Alaska Power Authority JOB NO.P5701.05 CLIENT Alaska Power Authority JOB NO.P5701 .05 PROJECT Susitna Hydroel ectri C Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-3 SHEET NO,9 OF 31 SITE Watana (North Bank) HOLE NO.BH-3 SHEET NO.1 0 OF 31 DEPTH I I DE,CRlPTION :GOLOR,TEXTURE.FOLIATION,'OINTING,FRACTURING,FAULT!NG,L.ENGTH REC DEPTH DESCRIPTIQ!-!:COLOR,TEXTURE,FOLiATlON,JOINTlNG,FRACTURING,FAULTl NG,LENGTH I REC ROCK TYPE OF RUN ROCK TYPE OF RUN (FT)AL.TERATION,WATER L.OSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC.1FT.)(ROD)(FT.]AL.TERATION,WATER L.OSS OR GAIN,CAVING.L.OST CORE,CEMENTING,ETC.1FT)(ROO) Diorite /241.8-242.2 Discoloration of feldspars,Run 44 Diorite Run 511 100 yellow stain.275.7 (94)243.0-243.6 Carbonate vein,0.3 inches wide,Run 45 tight.245.9 100 to 245.4-246.4 Numerous fractures,up to 0.25 to (100)280 280.8-281.2 Inclusion of dark green,fine 280.7 inches,healed with carbonate.Joint,10°,250.9 (229.4)grained diorite.Run 521100 250 1 10.5 inches of carbonate filling.280.7 (100)(204.8)247.5-250.4 Joints closely spaced. 248.0-248.6 Fracture zone,joints very closel Run 46 tospaced,healed with carbonate,some broken 284.7-302.8 Alternation zone,slightly 285.7bydrilling.250.9 100 altered hydrothermally.Within the alteration 248.8-248.9 Core broken by drilling,pieces to (100)zone are healed breccia zones up to 2.0 inches0.5 to 1.0 inches.255.9 wide,healed with dark green igneous rock and254.6-255.1 Fracture zone,very closely carbonate,moderately closely spaced.Run 531100 spaced,joints irregular,discontinuous,healec Feldspars stained yellow-green,moderately 285.7 (100)with ca rbonate.hard.Run 47 100 to 255.9 (100)290.7 to 290 260.9 (237 6)j Run 54/100 260 1 I ~290.7 (100)(213.0) Run 48 98 to 260.9 (92)295.7 to 265.6 I I I I I I Run 551100 295.7 (100) Run 49 100 I I I to 265.6 (100)300.7 to 300 270.7 (245.7) Run 561100 270 i I 300.7 (100)(221.2) 272.1-272.3 Numerous fractures filled with Run 50 100 to carbonate,approximately 10-20%of rock is 270.7 (92)305.7carbonate,some is stained red.to 274.1 Shear,20°,coating of clay gouge,306.4-307.0 Healed diorite breccia,hard.sl ickensi des.275.7 275.2 Healed breccia,30°,approximately 1-5 307.0-307.7 Numerous joints,20°,healed by IRun 571100 inches wide,healed with carbonate.carbonate,very closely spaced,tight.305.7 (100) Run 51 ~to (94)310.7 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUffALO.NEW YORK DRILLING REPORT CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project CLIENT Alaska Power Authority PROJECT Susitna Hydroe 1ectri c Proj ect SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.11 OF 31 SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.12 OF 31 DEPTH (FT.)ROCK T'(PE DEseRI PTI ON:COLOR,TEXTURE,FOLIATION,JOlNTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REG tROD) DEPTH lITJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOI NTlNG,FRACTURING,FAUL.TI NG, ALTERATION,WATER LOSS OR GAIN I CAVING 1 L.OST CORE,CEMENTING,ETC. LENGTH OF RUN 1FT.) REG (ROD) Run 64/100 340.7 (100) to 345.8 Run 651100 345.8 (92) to Run 681100 360.7 (100) to 365.7 Run 66\100 350.7 (100) to 355.7 Run 691100 365.7 (100) to 370.7 Run 70\100370.7 (72) to375.7 Run 671100 355.7 (100) to 360.7 343.2 Carbonate vein,30°,0.5 to 1.0 inches wide,minor vu9s. 346.8-348.2 Joints (3),10°,closely spaced, slightly to moderately altered hydrothermally affecting 20-30%of feldspars.Healed with carbonate,rusty-orange stained,moderately hard. 348.5-392.3 Joints moderately close to close-I 350.7 ly spaced,most healed by carbonate,chlorite coating,average 1 to 2 feet. 348.5-356.4 Core broken by drilling,pieces 3 to 6 inches. 349.4 Joint,40°silt/clay coating. 350.1 Joint,40°,trace of si It/clay coatingi 353.0 Joint,30°,slickensides on chlorite, carbonate with trace of silt and clay. Healed but broken by drilling. 356.1 Joint,40°,coated with carbonate and sandy-s il t. 356.6-356.75 Healed breccia,70-80%diorite fragments,in a dark green igneous matrix, hard. 357.4-357.5 Pods of carbonate,up to 0.75 inches long,approximately 10%of rock. 358.2-363.5 Irregular patches of red staining in core,60-70%. 359.7-360.8 Joint,10°,carbonate healed, tight,slightly to moderately altered hydro- thermally affecting 10-20%of feldspars within 1.0 inch.Carbonate is rusty-orange stained, possible clay coating on surface. Di orite 370 1(303.1) 360 ,(294.9) 350 (286.7) Run 571 100 (100) Run 581100 310.7 (100) to 315.7 Run 591100 315.7 (100) to 320.7 Run 611100 325.7 (100) to 330.7 RUfl63 I 100 335.7 (100) to 340.7 Run 60\100 320.7 (100) to 325.7 Run 621100 330.7 (100) to 335.7 310.6-311.5 Numerous joints healed with carbonate,oriented at 40°,irregular,dis- continuous fractures filled with carbonate, generally less than 0.25 inches. 315.7-348.5 Joints moderately close to widely spaced,many joints healed with carbonate,~I I average width 2 to 3 feet. 319.9 Healed shear,oriented at 25°,0.5 inches wide,hard. 321.7-325.4?Healed breccia,70-80%diorite 329.1-329.7 )fragments,hard. 331.4 Healed shear,30°,0.5 inches wide, healed with dark 9reen igneous material, carbonate is along contacts. 336.5-340.7 Joints,10°,closely spaced, slightly to moderately altered hydrothermally, 0.5 inches wide.Healed with carbonate, yellow-orange stainin9 (iron oxide?),moder- ately hard.Alteration affects 20-30%of feldspars. Diorite 340 278.5) 310 (253.9) 320 (262.1) 330 (270.3) ]•J '1 ~1 Ji 1 ~~~J J ,~I J jj -.::1 .,I -'C'"""J '~?l '-""'-1 ~--l "_."..._-)c-)····_·1 1 -].-.,.-J --~)]r-] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO.P5701 .05 HOLE NO.BH-3 CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO,P5701.05 HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO·13 OF 31 SITE Watana (North Bank)SHEET NO,14 OF 31 DEPTII (FT.)ROCK TYPE OESCRIPfi ON :COLOR,TEXTURE,FOLlATION ,JOINTING,FRACTURING,FAULTI NG I AL.TERATION,WATER L.OSS OR GAIN,CAVING,"LOST CORE,CEMENTING,ETC. LENGTH OF RUN 1FT.) REC (ROD) DEPTH [FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST COREl CEMENTING,ETC. LENGTH OF RUN (FT.} REC (ROD) -._- 100 (88) Run 801 100 Run 77 Run 78 405.8 to 410.8 415.8 I (94) to 420.9 Run 791100 410.8 (90) to 415.8 Run 821100 425.8 (100) to 430.7 431.6 Healed joint,30°,0.5 inches of carbonate filling,slickensides,trace of clay. 406.3-408.7 Shear and fracture zone,joints very closely spaced. 406.3 Joint,80°,slickensides on chlorite. 407.3-407.7 Core broken by drilling,pieces 0.5 to 1.0 inches,minor slickensides. 409.1-409.5 Alteration zone,core bleached to yellow-gray,slightly to moderately altered hdyrothermally.Feldspars are stained and altering to clay.Trend is parallel to healed shear ~t 40°,crosscuts this zone. 414.4-424.4 Shear/alteration zone,core is bleached to light yellow-green,slightly altered hydrothermally,feldspars.stained,hardf--l----j to moderately hard. 415.0 Shear,20°,slickensides on chlorite and carbonate filling.Crosscuts 1.0 inch wide zone of very closely spaced joints healed with carbonate. 416.6 Possible shear,30°,healed by carbonate. 416.7-450 ..5 Joints close to moderately Closel1:,~~spaced,average 1.0 to 2.0 feet.Chlorite un coating of carbonate.420.9 419.7 Healed shear,20°,up to 0.25 inch t thick,healed with dark green igneous 0 material and carbonate.425.8 424.2 Two joints very closely spaced,20°, slickensides on chlorite and carbonate. Rusty-orange stain on carbonate. 426.7 Joint,healed,20°,'rusty-orange,less than 0.1 inches of carbonate.Alteration of feldspars to 0.25 inches on either side. 428.2 Healed joint,30°,rusty-orange stain, slickensides on carbonate and chlorite. 437.5 Joint,10°,trace of Silty-sand, ~lightly altered to 0.5 inches on either side. Di orite 410 (335.9) 420 (344.0) 430 (352.2) (69) Run 701 100 370.7 (72) 375~7 Run 711100 375.7 (80) to 380.7 Run 721 100 380.7 to 385.9 Run 731 96 385.g (54) to 390.7 Run 741 100 390.7 (58) to 394.3 Run 76 108)~BH-\ Ru n '-c::7-=f7-=1C-=-0OC- 400.8 (74) to 405.8 365.8-366.6 Fracture zone,joints and fractures healed with carbonate very closely spaced,joints at 20°.Fractures are i rregu- lar and discontinuous,tight. 366.8-367.1 Healed breccia,60-70%diorite fragments,in a dark green igneous matrix, hard. 371.2-371.8 Red staining on core. 372.2 Joint,10°,0.1 inch coating of carbonate,chlorite,clay. 374.3-388.7 Joints close to moderately closely spaced,averaging 0.5 to 1.5 feet. 374.6 Joint,0°to 10°,coated with carbonate chlorite,and silt/clay,approximately 0.1 inches wide. 379.4-388.2 Alteration zone,slightly altered hydrothermally,30-40%of feldspars show staining and beginning to alter to clay. Close to very closely spaced joints,tight, healed with carbonate,moderately hard. 379.5 Joint,60°,filling of silt/clay, approximately 0.25 inches thick. 379.9 Joint,80°,coated with silt/clay. 384.5 Joint,35°,with faint slickensides, chlorite staining. 384.8-385.2 Shear,70°,predominantly a breccia with layers of gouge to 0.5 inches. Breccia/gouge partially healed with carbonate,soft. 386.2-386.4 Core broken by drilling,averag 1.0 inch,pieces coated with carbonate and c--------~~ chlorite.Run 75 100 386.4 Shear,50°with 0.1 inch of breccia.394.3 (46) 386.5-387.0 Shear,0'to 10°,0.1 inch of to gouge.Slickensides on chlorite,slightly 399 3 to moderately altered hydrothermally,. friable. 392.3-416.7 Joints,very close to closely spaced,numerous zones of core broken by drilling,averaging 0.5 to 1.0 feet. 394.7-396.3 Joints,healed with carbonate, some broken by drilling. Diorite 400 (327.7) 380 (311.3) 390 (319.5) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT PROJECT Susitna Hydroelectric Project CLIENT A1as ka Power Authority PROJECT SU si tna Hydroe 1ect ri c CLIENT SITE Al aska Power Authority Watana (North Bank) JOB NO.P5701 .05 HOLE NO.BH-3 SHEET NO.15 OF 31 SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.16 OF 31 DEPTH (FT.l ROCK TYPE DESCRIPTION;COLOR,TEXTURE,FOLIATION ,JQINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC LI::NGTH OF RUN (FT) RE'C (ROD) DEPTH (FT.l RocK TYPE oEseR I prl ON :COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAU LTJ NG, ALTERATlON~WATER lOSS OR GA!N,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.) REC (RQD) Run ~ Run 911100 46e67 (100) 463.7 Run 921 100 463.7 (76) to 468.3 Run 901100 455.6 (78) to 460.7 86 (0) (8) 96 100 (0) 100 (0) 100 (0) 100 (0) 100 (81 ) Run 94 to 478.7 Run 99 496.5 to 500.7 Run 93 468.3 to 473.7 Run 95 478.7 to 483.7 Run 96 483.7 to 488.7 Run 98 491.5 to 496.5 473.7 I---+---------J Run 97 488.7 to 491.5 I }{ffij 483.7-486.9 Shear zone,partially healed. Breccia healed with carbonate. 469.5 Fragment with faint slickensides. 470.3 Joint,0·,faint slickensides. 471.0 Shear,10·,approximately 0.5 inches of gouge and breccia.Core is badly broken. 494.6-503.5 Shear zone,partially healed, contact at 20·.Breccia and gouge healed with carbonate. 474.1-530.0 Shear/alteration zone,core is bleached to light yellow-green to light yellow-gray,moderate hydrothermal alteration. Approximately 50%of feldspars have altered to clay.Numerous carbonate healed joints, close to very closely spaced.Moderately hard to soft,locally friable. Di orite 500 (409.6) 470 (385.0) 490 (401.4 ) 480 (393.2) 100 (100) 100 (100) Run 85 Run 881100 445.6 (100) to 450.6 Run 87 440.7 to 445.6 Run 86 438.0 to440.7 Run 891100 450.6 (100) to 455.6 439.9 Joint,15°,healed with carbonate, trace of silty-sand,broken by drillin9. 443.2 Joint,20·,slickensides on chlorite. 447.0-447.2 Shears (2),20·and 40·, approximately 0.3 inches of chlorite breccia, slickensides. 449.0-454.5 Healed diorite breccia,80 to 90% diorite fra9ments,in dark green,fine grained diorite,hard. 450.5-458.3 Joints and fractures very closely spaced,tight,less than 50%healed by carbonate. 457.2 Joint,20·,slickensides on carbonate and chlorite. 457.8 Joint,0·,healed with carbonate, slickensides. 450.5-475.9 Joints,very close to closely spaced,average 0.5 to 1.0 feet. 459.7-460.7 Core broken by drilling,pieces 0.5 to 1.0 inch.Most surfaces have chlorite and carbonate stain,potential fracture zone. 461.5 Joint,O·to 10°,gray-green coating, similar to clay. 463.5-464.1 Fracture zone,joints and frac- tures very closely spaced,fragments have gray-green coating,broken by drilling. 467.4-475.9 Shear/fracture zone,joints very closely spaced.Approximately 25%of the core is badly broken by drilling. Oiorite 440 (360.4) 450 (368.6) 460 (376.8) ~1 J 1 j~'~~1 m '1j, ~-J -1 '---1 --]'1 ---]---1 1 --]----1 ']--1 -]-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO,P5701.05 HOLE NO,BH-3 CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO.P5701,05 HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.17 OF 31 SITE Watana (North Bank)SHEET NO.18 OF 31 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT Al aska Power Authority PROJECT Susitna Hydroelectric Project CLIENT Alaska Power Authority PROJECT Sus itna Hydroel ectric Proj ect SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO 19 OF 31 SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.20 OF 31 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TExTURE,FOLIATION,JOINTING,FRACTURING,FAUL.TI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REG (ROD) DEPTH (FTJ ROCK TYPE DEseRI PTI ON :COLO R,TExTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,L.OST CORE,CEMENTING,ETC. LENGTH OF RUN (FT,) REG (ROD) 100 (96) 100 (96) 100 (98) 100 (100) 100 (100) un 123 605.7 to 610.8 un 121 595.4 to 600.5 un 122 600.5 to 605.7 Run 1251100 615.B (100) to 620.8 Run 126 620.8 to 625.9 fun 124 610.8 to 615.8 622.4-633.0 Alteration zones,closely spaced, approximately 0.5 feet wide.Feldspars stained,hard. 622.4-754.0 Joints close to moderately closel spaced,trace of carbonate,chlorite common. Average 0.5 to 1.5 feet. 600.5-622.4 Joints close to very closely spaced,numerous joints are healed with car- bonate.Tight and competent,some broken during drilling,carbonate filling averages 0.1 to 0.25 inches.Moderately spaced healed shears,tight. Oiorite 610 499.7) 620 ,(507.9) 600 (491.5) 100 (100) 100 (100) 100 (100) 100 (100) un 117 575.1 to 570.7 to 585.2 580.1 Run 116 570.7 to 575.1 Run 118 580.1 pun 120\100 590.3 (100) to 595.4 Fun 1191 100 585.2 (100) to 590.3 560.9-561.0 Two shears,very closely spaced,,~u~n~~~~-----1 30°.Upper shear,0.5 inches wide breccia Run 115 zone;lower shear,coating of carbonate.565 7 563.6-565.7 Shear/fracture zone,joints . very closely spaced,some joints have a to silt/clay coating,gouger?). 600.4-605.3 Slightly to moderately altered hydrothermally,most joints are carbonate healed.Feldspars are discolored and and beginning to alter to clay,moderately hard. 597.2-600.5 Felsic dike (?),light gray, fine to medium grained.Brittle,slightly altered hydrothermally,highly fractured, numerous drilling breaks. 565.7-600.5 Joints moderately close to wide, chlorite coating,with trace to coating of carbonate. Di orite 590 483.3) 570 (466.9) 580 (475.1) IRun 121 100 (96) 626.8 Carbonate vein,offset by joints at offset approximately 0.25 inches. 600,IRun 127 625.9 to 630.7 100 (100) 1iI J ",1 ]"~ ]21 'A ji ,.')1 "'~"1 "-1 1 -'1 '~"]~'l -1 "'],-."-J ~'l J 1 -1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT A1as ka Power Authority PROJECT Susitna Hydroelectric Project CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.21 OF 31 SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.22 OF 31 DEPTH DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG,L.ENGTH REC DEPTH OESCRIPTl ON :COLOR,TEXTURE,FOLIATION ,,JOINTING,FRACTURING,FAUL.TlNG I L.ENGTH REC ROCK TYPE OF RUN ROCK TYPE OF RUN (FT.)AL.TERATION,WATER L.OSS OR GAIN,CAVING,Lo'ST CORE,CEMENTING,ETC.(FT)(ROD)(FT.)AL.TERATlON,WATER L.OSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.(FT.)(RQD) 630 Diorite Run 127 Diorite Run 134 100 (516.1)660.7 (100) Run 128 100 to 630.7 (100)665.7 to 635.7 'Run 1351 100 665.7 (98) Run 129 100 1 I 1 to ~635.7 (86)670.7670e~to (548.8) 640.7 Run 1361 100 640 1 I .~670.7 (97) (524.3)\~to Run 130 100 673.8 640.7 (100)Run 1371 100 to 673.8 (92)~g 645.7 to ~~677.0-681.1 Joints very close to closely 678.8~,~--spaced. Run 131 100fir-645.7 (100)Run 138 TOO 678.8 (45)i~to 680 685~8 650.7 (557.0) :1.Run 1391100 650 1 1 ~~680.8 (80)1(532.4) Run 132 100 to 650.7 (100)683.1 Irregular shaped inclusion of felsic 685.7 to materi a1. 655.6 IRun 1401100 685.7 (80) 657.0 Shear,20 0 ,up to 0.25 inches wide,r"lJ3 100 t 1 1688.8-689.4 Fracture zone,core broken by 1 to healed primarily with carbonate,but also 655.6 (100)690.7 some dark green diorite.to drilling,joints very closely spaced. 657.0-657.8 Joints,10 0 -20 0 ,very closely 690 spaced,20 0 •Healed with carbonate,tight.660.7 (565.2)J 1 IRun 1411100 660 ~I (88) 540.6) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT Alas ka Power Authority PROJECT Susitna Hydroelectric Project CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.23 OF 31 SITE Watana (North Bank) JOB NO.P5701.05 HOLE NO.BH-3 SHEET NO.24 OF 31 DEPTH (FT.)ROCI<TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAU LTI NG, ALTERA.TION,WATER LOSS OR GAIN,CA ....ING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT) REC (RQO] DEPTH 1m ROCK TYPE OEseRI PllON :COLOR,TEXTURE,FOL.IATION,JOINTING,FRACTURING,fAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,L.OST CORE,CEMENTING I ETC, LENGTH OF RUN (FTj REC (ROD) Run 1451100 710.7 (88) very closel~Run 141 690.7 to695.7 Run 1441100 705.7 (100) to 710.7 Run 1431100 700.7 (78) to 705.7 Run 1481100 724.8 (100) to 730.0 Run 1491100 730.0 (100) to 735.0 Run 1501100 735.0 (100) to 740.2 Run 1511100 740.2 (100) to 745.2 729.2 Joint,10°,trace of sandy-silt. 737.6 Healed breccia,70-80%diorite fragments in a dark green diorite matrix.Hard,numerous irregular,discontinuous fractures filled with carbonate,up to 0.3 inches,comprise 10%of rock. Di orite 730 (598.0) 740 (606.2) 100 (88) 100 (98) to 700.7 Run 142 695.7 695.4-696.1 Fracture zone,joints spaced at 60'. 697.7-698.4 Fractures very closely spaced, discontinuous,healed with carbonate. 699.8 Felsic dike,medium gray,aphanitic, highly fractured but tight,0.3 inches wide. 702.0-707.7 Shear/alteration zone,bleached to a medium yellow-green,generally slightly altered hydrothermally.Hard to very hard. 702.7-703.5 Felsic dike,light green-gray, fine grained,fractured but tight.At 703.0 dike has been offset along a joint at 60°,approximately 1.0 inch. 704.2-705.7 Alteration is slight to moderate,with feldspars altering to clay. Rock is soft to moderately hard,friable along shear.Shear is at 705.0 and 705.5, approximately 0.25 inches of breccia and gouge.Minor sulfide mineralization. 704.5-705.7 Core loss 0.2 feet. 710.3 Felsic dike,50·,gray-green,fine grained,unfractured,chill margins. Approximately 1.5 inches wide. Diorite 700 (573.4) 710 (5B1.6) 711.0 Felsic dike,40·,gray-green,fine I to grained to aphanitic,fractured,chill margins 1 tight.7 5.6 Run 1521100 745.2 (98) to 750.3 Run 1541 100 (96) Run 1531100 750.3 (100) to 755.4 754.0-773.9 Shear/fracture zone,joints very closely spaced,most are tight,some carbonate healed joints.Pieces of intact core f------+-----I approximately 1.0 foot long,brittle. 745.7 Joint,45°,slickensides on chlorite. 753.6 Shear,10°.healed. 749.5 Joint,80·,slickensides on chlorite. 750 (614.4) 100 (96) 100 (100) Run 146 715.6 to 719.7 Run 147 719.7 to 724.8 717.2 Felsic dike,20°,gray green,fine grained to aphanitic,slightly fractured, chill margins,2.0 inches wide. 718.3 Joint,10°,trace of sandy-silt. 719.0 Joint,10°,slickensides on chlorite, coating of carbonate and chlorite gouge. 720 1(589.8) '\~,~~1l ~"1 ,': ']-1 1 ~J 1 1 -_-I -~l ~'-'-'1 1 -']}~-]1 ) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT A1as ka Power Authority JOB NO.P5701.05 CLIENT Alaska Power Authority JOB NO.P571O.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-3 PROJECT Sus itna Hydroe1 ectri c Proj ect HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.25 OF 31 SITE Watana (North Bank)SHEET NO.26 OF 31 DEPTH (FTJ ROCK TYPE OESCRJPTI ON :COLOR,TEXTURE,FOLlATION,JOINTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,,LOST CORE,CEMENTING,ETC LENGTH I REO OF RUN (RQDl(FT) DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REO (RQD) Run 1551100 760.5 (98) to 765.5 sl ckens des on ch10r te'IRun 154 sl ckens des on ch10r teo 755.4 sl ckens des on ch10r te to 760 (622.6) Di orite 757.0 Joint,30°, 757.2 Joint,60°, 757.7 Joint,30°, and carbonate. 758.6 Joint,30°,slickensides on chlorite and ca rbonate. 759.3 Joint,30°,slickensides,trace of gouge. 764.3-769.3 Most joints becoming healed with carbonate,less than 0.1 inch thick. 768.0 Shear,30°,1.0 inches of breccia, slickensides on chlorite,talc (?). 760.5 100 (96)790 J Diorite (647.1) IRun 1601 100 (100) IRun 1611 100 790.8 (100) to 793.5 fun 1621100 793.5 (76) to 798.5 Run 1581100 775.5 (98) to 780.6 Run 1561100 765.5 (96) to 770.5 Run 1571 98 770.5 (70) to 775.5 1------+----- Run 159 100 780.6 (100) to 785.7 100 (100) 100 (100) to un 163 100 798.5- 800.7 (100) 810.7 [Run 1661100 810.7 (100) to 815.7 [Run 1651100 805.7 (100) Fun 167 815.7 to 820.7 817.5 Felsic dike,15°,light gray,fine grained to aphanitic,1.0 inch wide,margins are fine grained quartz and feldspar,with 0.5 inch zone of quartz. 800.5-800.7 Alteration zone,slightly altered hydrothermally,slightly bleached. Between a set of joints very closely spaced,at 20°,carbonate healed.Approxi -run 164 mately 10%of feldspars are altered to 800 7 clay.. 801.1-840.8 Joints are closely spaced,aver-to age 0.5 to 1.0 feet.Chlorite filling,trace 5 7 of carbonate.80 . 801.3 Felsic dike,light gray,fine grained, 0.5 inches wide,offset by a healed shear. 805.7-807.0 Joints,very closely spaced, tight,healed with carbonate. 806.7 Joint,20°,slickensides on chlorite. 812.5 Felsic dike or healed breccia,light gray,fine grained to aphanitic ground mass with diorite fragments.Ti ght contacts,0.5 inches wide,10°,hard. 800 1(655.3) 82D 111;71.7\ 810 (663.5) 100 (lDO) Run 16D 785.7 to 790.8 773.9 Joint,35°,slickensides on chlorite. 773.9-801.1 Fracture zone,joints are close to very closely spaced,some healed with carbonate,tight,pieces average generally to 1.0 foot,but are brittle. 770 (630.7) 780 (638.9) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFA LO •NEW YORK DRILLING REPORT CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO.P5701.05 HOLE NO.BH-3 CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO.P5701.05 HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.27 OF 31 SITE Watana (North Bank)SHEET NO.28 OF 31 DEPTH 1FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC LENGTH REC O~~~N (RQDl DEPTH (FT.l ROCK TYPE ~E5CRIPTION :COLOR I TEXTURE,FOLiATION,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT) REC [RODI Run 1771100 860.7 (100) to 865.7 Run 1741 100 (100) Run lfOTlOO 858.7-1(100) 860.7 Run 1791100 870.8 (98) to 875.7 Run 1811100 880.7 (94) to 885.8 Run 1781100 865.7 (100) to 870.8 Run 1801100 875.7 (100) to 880.7 ,Run 1751100 855.0 (100) to 858.7 861.3-862.0 Several inclusions of dark green, fine grained diorite,up to 0.75 inches in diameter. 871.7,872.0 Inclusions of dark green,fine grained diorite,1.0 and 2.0 inches, respectively. 873.1-955.7 Diorite changes to a light gray-green.Increase in quartz,possibly up to 10%. 878.6 Felsic dike (?),60°,light gray,fine grained,2.0 inches wide,irregular contacts, hard. 879.3-882.5 Healed breccia zone. 880.3 Shear along joint,at 15°,approximate- ly 0.1 inch of clay/silt,carbonate;f---+-----1 gouge (?). 881.6 Shear along joint,at 20°,0.5 inches wide breccia gouge zone.Partially healed with carbonate. Di orite 870 (712.7) 860 (704.5) 880 (720.9) to Run 1681 98 820.7 (96) to 835.2 to 825.5 Run 169~;-­ 825.5 I (90) to 830.5 845.2 Run 1711100 835.2 (100) to 840.2 Run 1741100 850.2-(100) 855.0 Run 1731100 845.2 (100) to 850.2 I---~--/Run 170 100 830.5 (100) 821.4 Joint,50°,coating of sandy-silt/clay, gouge (?). 828.9-844.8 Diorite becomes light to medium green,possibly due to changing composition of feldspars,may be an increase in quartz content. 831.3 Felsic dike,90°,light gray,medium grained,1.0 inch wide. 831.3-833.6 Gradational change in texture from medium grained to fine grained.Sharp contact with the underlying medium grained diorite,unfractured. 840.8-882.3 Joints close to moderately close_IRun 1721100 ly spaced (average 1.0 feet),chlorite,trace 840.2 (100) to occasional filling of carbonate. 847.8,848.0 Inclusions of dark green,fine grained diorite,1.0 inch in diameter. Di orite 830 (679.9) 840 (688.1) 850 (696.3) j A 1 J n -]~~j 1 ~n ] 'J ]I -J -~---1 1 1 -,-,1 -~~1 1 -1 1 1 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT Alaska Power Authority JOB NO.P5701.05 CLIENT Alaska Power Authority JOB NO.P571O.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-3 PROJECT Susitna Hydroelectric Project HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.29 OF 31 SITE Watana (North Bank)SHEET NO.30 OF 31 DEPTH (FT.)ROCK TYPE DESCFHPTI ON:COLO R,TEXTURE,FOLIATlON,JOt NTlNG,FRACTURING,FAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,L9ST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REC (ROD) DEPTH (FT.l ROCK TYPE DI;SCRIPTI ON:COLOR,TEXTURE,FOL.IATION,JOI NTI NG ,FRACTURING,FAUL.T!NG, AL.TERATION.WATER LOSS OR GAIN,CAVI NG.LOST CORE,CEMENTI NG,ETC. L.ENGTH OF RUN (FT.) REC (RODj 905.1-906.0 Core broken by drilling or pos- sible fracture zone.Pieces average 1.0 inch.IRun 187 Run 1831 (100100) Run 1891 100 (98) to 905.7 to 925.8 Run 191 1100 925.8 (92) to 930.8 IRun 1891100 915.7 (98) to 920.7 IRun 1901100 920.7 (100) IRun 1g311 00 935.9 (100) to 940.7 IRun 1941100 940.7 (100) to 945.8 IRun 1921100 930.8 (100) to 935.9 946.1 Shear,25°,up to 0.5 inches of breccia gouge. Run 1951100 945.8 (100) to 950.7 923.5-925.1 Fracture zone,joints very close- ly spaced.Most are tight but have been broken by drilling. 926.6-928.2 Shear/alteration zone,core bleached to light yellow-green,slightly al- tered hydrothermally,hard to moderately hard. Upp~r contact is gradational,lower is sharp along a 60°carbonate healed joint. 927.2 Shear on joint at 35°,approximately 0.5 inches of breccia gouge,·slickensides. 928.3-928.7 Irregular fractures healed with carbonate,up to 0.3 inches,less than 5%of rock. 929.5-955.7 Fracture zone,joints very close- ly spaced,most are tight,approximately 25% heal ed with carbonate.Minor sulfide mineral-I I I ization,unbroken pieces range from 0.5 to 3.0 feet. 933.2-946.5 Shear/alteration zone,bleached to light yellow-green,slightly altered hydrothermally.Feldspars are stained, hard to moderately hard. 934.9 Shear,40°,coating of clay gouge, coincident with a healed shear. 943.6 Shear,30°,up to 0.5 inches of brecci a gouge. Diorite 930 1(761.8) 920 (753.6) 940 (770.0) 100 (92)905.7 to 910.7 Run 1881100 910.7 (100) to 915.7 Run 1821100 885.8 (94) to 890.7 Run 1861100 900.7 (80) IRun 1851100 896.6 (90) to 900.7 IRun 1841100 892.0 (74) to 896.6 IKun Itll 908.0-929.5 Joints are moderately close to close,averaging 1.0 to 1.5 feet. 898.8-899.1 Core broken by drilling,pieces are 1.0 to 2.0 inches,fresh,angular. 912.6-913.1 Fracture zone,joints very closel spaced at 10°. 882.3-888.1 Core broken by drilling,pieces generally less than 3.0 inches.Possible fracture zone (?). 888.1-908.0 Joints closely spaced,with local zones of very closely spaced joints. Trace to occasional filling of carbonate. 894.5-897.4 Shear/fracture zone .(?),joints and fractures close to very closely spaced. 894.5-895.7 Core badly broken by drillin9, pieces 1.0 to 2.0 inches.Two joints at 10°have slickensides,pieces are angular, fresh to slight chlorite staining. 903.0 Joint,10°,healed,carbonate filling to 0.5 inches. 903.8-904.2 Core broken by drilling,pieces 0.5 to 1.0 inch. Diorite 910 (745.4) 890 (729.0) 900 (737.2) ACRES AMERiCAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT Alaska Power Authority PROJECT Susitna Hydroelectric Project JOB NO.P570l.05 HOLE NO.BH-3 SITE Watana (North Bank)SHEET NO.31 OF 31 DEPTH (FT.) 950 (778.2) ROCK TYPE Diorite OEseRI prl ON:COLOR,TEXTURE,FOLIATION I JOINTING,FRACTURING,FAULTI NG, ALTERATION,wATER LOSS DR GAIN,CAVING,LOST CORE,CEMENTING,ETC 948.0-948.9 Alteration zone,slightly altered hydrothemlally,approximately 10-25%of feldspars are altering to clay. Hard to moderately hard. LENGTH REC OF RUN (fT.)(ROD) Run 195 100 (100) IRun I Y61IITO 950.7 (100) to 955.7 I.955.7J I END OF BORING ~782.9) ~~l 1 ~.~1 J ]1 ~~~r '1 ) ],c_')'-----J -']--)-"~l c,._,1 --']-~l 1 .,.,.,'.'}') Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American I ncorpora ted 'ConsultingEngi neers Buffalo,New York SUMMARY LOG SUMMARY LOG REMARKS • Joint,slickensides Shear/fracture zone Shear/alteration zone. Shear/alteration zone. Shear/fracture zone. Shear/alteration zone. Shear/alteration zone. Job No.P5700.05 Hole No.,---.:B'-'.H:....':=..3 _ Sheet No._2 of _3 ROCK TYPE Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana (North Bank) Alteration zone. Alteration zone. Alteration zone. m REMARKS Alteration zone. Breccia,healed. Shea rs,hea led. Shear. TOP OF ROCK 31.7' Breccia,healed. Shear,alteration zone. Shear. Fracture zone, healed. Fracture zone. Job No.P5700.05 Hole No ..__B""H_,.:...3 _ Sheet No._1 of _3_ ROCK TYPE ROO % ALASKA POWER AUTHORITY PERMEABILITY ICORE RECOVERY (K)em/l.e.% 10-f>,lOA 10-2 Project Sus itna Hydroe1 ectri c Proj ect Site __Watana (North Bank) Client 012151 20 I I I I I I I I I I I I I I I I I I I I I I I 16 20 220+-I11III I I I I 18~+++t+~ ~E:T~~I ~~~.~. Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG REMARKS Zone of joints with s1i c kens ides. Shear/alteration zone. IShear/fracture zone. Job No.P5700.05 Hoi e No.-'oB..,H_-3 ___ Sheet No.3 of _3_ ALASKA POWER A~U~TH~O=R~IT~Y~___Client Project Susitna Hydroelectric Project _ Site Watana (North Bank~ 1536 D(~T~I ~~~_~. 720 I •I '160 740 -+•I I i-H- Fracture zone. 900 ,...._"1;;,·,'~l'l~"=~'~',':I,','!!=iii@ Jo I':"''''!*''''II Shear. 920 ~Ilitjj~f1 Shear/fracture/~O --.-'-~~''''"''I~~!!~±;~i!.alteration zone. ~l==tttTTmT+TTt+R=t-ll+++-1 I END OF BORING 955.7' 980 780 • ~")1 ;-~1l r~~J ., J -, ~.-]--')..~]....."'J ..-,..-]"1 ·-_·······1 "J ·~·······1 ]1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT:ALASKA POWER AUTHORITY JOB NO.:P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT: SITE: Susitna Hydroelectric Project Watana (North Bank) HOLE NO.:BH-4 SHEET NO.1 OF 31 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.2 OF 31 LOCATION:LATITUDE N3,228,42l ELEVATIONS:DATUM MSL,A.S.P.C .•Zone 4 DEPARTURE E7 43.471 GROUND SURFACE 2187.8 AZIMUTH 060°ROCK SURFACE 2177.3 DIP 58°BOTTOM OF HOLE 1382.5 WATER TABLE NOTES:1)Depths measured alon9 hole.True depths in (). 2)All angles measured to the core axis. 20 (17.0)1 I /- APPROVED.L/1I:~~~~~ CONTRACT(lR:Interstate Exploration Inc. LOGGED BY·,K.J.White,M.P.Bruen REC [ROD) 100 (33) 100 (35) 100 (70) 100 (49) 100 (78) LENGTH OF RUN (FT) Run 11 Run 6 30.8 to 35.7 Run 10 45.8 to 50.8 Run 7 100 (0) Run 8 37.1 89 to (0) 40.7 Run 9 40.7 1 100 to (33) 45.8 DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTI.NG.FRACTURING,FAULTI NG I ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. 12.4-21.0 -Joints closely to moderately closely spaced,trace of iron oxide staining,Run 3 most joints have a trace of carbonate filling.21.0 15.8 -Joint,60°,0.1 inches of silt/clay,to poss i bl e shear..25.2 21.0-70.6 -Joints closely to very closely RUTI'r spaced,iron oxide staining.25.2- 21.8-22.5 -Shear/fracture zone,joints very ~ closely spaced,slightly weathered.Run 5 22.3 -Breccia/gouge,0.25 inches thick 27.1 on joint at 50°.to 24.1-24.3 -Fracture zone,broken core,yellowt-30_,_8-j1--_--I calcareous silt coating. 30.2-34.5 -Color changes to a light gray- green.Contains fragments of argillite to 0.5 inches,comprising approximately 5-10%. 32.5-41.0 -Fracture zone,joints very closely spaced,pieces are 1.0 to 2.0 inches. 34.0 -Joint,80°with a silty-sand coating. 37.4 -Joint.40°with a silty-clay coating. 38.5-39.6 -"Granitic"rock,medium grained, 20-30%quartz,mafics less than 1.0%.Light yellow-gray rock,slightly to moderately altered/weathered,badly broken.Joint coated with calcareous clay.Contacts are fractured,not exposed. 39.6-41.0 -Slightly to moderately weathered. 43.4-44.6 -Fracture zone,very closely spaced joints.silty/sand coating. 48.9-49.6 -Probable fracture zone,pieces average 1.0 inch. 50.1 -Joint,40°,sulfide mineralization. ROCK TYPE Andesite Porphyry DEPTH {FTJ 50 (42.4) 40 (33.9) 1. 30 (25.4) 0/0 REC (RQD) Run 1 12.4 1 100 to (92) 16.1 Run 2 16.1 I 100to(96) 21.0 CASING DIAMETER.NW (3.0")J.D. CORE DIAt,lETER;NW (1.75")0.0. DATE;February 1,1982 DRILLING DATES,.Sept.llTO Sept.23.1981 DATE;September 1981 TOP OF ROCK DESCRIPTION,COLOR ,TEXTURE,FOLIATION,,JOINTING,FRACTURING,FAULTING,I RUN ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC,LENGTH Overburden and cobbles. Medium gray to medium 9reen-gray,aphanitic groundmass with white.fine to medium grained plagioclase phenocrysts (20-30%),up to 0.25 inches.Flow structures visible in some sections.Fresh to slightly weathered,hard to very hard.Occasional pods and stringers of carbonate,less than 0.5 inches,joints moderately closely spaced,generally iron stained and carbonate coated. 6.5-12.4 -Very weathered fractured bedrock. Casing Advancer Diamond Core -Triple Tube SOIL ROCK Andesite Porphyry ROCK TYPE. Overburden OEPTH {FT.) DRILLINGt,lETHOD: 0.0 12.4 (10.5) 10 (8.5) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.3 OF 31 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO BH-4 SHEET NO.4 OF 31 DEPTH (FT.)ROCK TYPE DESCRIPTlQ.!'j :COLOR,TExTURE,fOLIATION,JOI NTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. LENGTH OF RUN (FT) REC (ROD) DEPTH (FT)ROCK TYPE DESCRIPTION COLOR,TEXTURE I FOLIATION,JOI NTING,FRACTURING,FAULTI NG I ALTERATION,WATER LOSS OR GAl N,CAYI NG,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT) REC (ROD) f----.l--------1 IR~:~3 11 0)57.5-24 Run 14 59.2 1100 to (40) 64.3 Run 11 50.8 98 to (60) Run 12 55.6-100 57.5 (0) 86 (41) 100 (67) 85 (49) 95 (23) 100 (58) 100 (53) 96 (53) Run 26 Run 21 94.7 to 99.6 Run 22 99.6 to 104.5 Run 19 84.5 to 89.6 Run 23 104.5 to 108.2-109.8 -Slightly to mOderately weathered,,109.5 joints very closely spaced. 109.8-112.5 -Fracture zone,joints very IRun 241 92 closely spaced,silt and clay coating.l---------J--iQ.L1 102.9-105.2 -Fracture zone,joints very closely spaced,pieces 1.0 to 2.0 inches,iron oxide stained.Core loss 0.9 feet. 84.5-112.0 -Rock changes to light green-gray with lithic fragments.Some flow structure at 70 c ,fragments of argillite,diorite,and andesite up to 1.0 inch but generally less than 0.5 inches. 88.7-90.1 -Shear/fracture zone,joints very closely spaced,at 10 0 and 60 0 • 88.9-89.1 -Breccia/gouge fragments.Run 20 92.0-102.6 -Joints close to moderately closely 89.6 spaced,open at 10 0 to 20 0 ,irregular and to rough.Heavy iron oxide staining and 94.7 organics (?). Andesite Porphyry 110 (93.3) .'112.0+-~Run 25 (95.0)Diorite Medium gray-green,medium grained,20-30%110.8 mafics,quartz less than 5%,trace of sulfides.to Fresh,hard to very hard,joints closely to 115.1 very closely spaced. I 90<776.3) _100 (84.8) 98 (8) 100 (72) 100 (60) 100 (64) un T9 Run 17 74.3 to 79.5 Run 18 79.5 to 84.5 Run 16 69.3 to 74.3 Run 15 64.3 to 69.3 53.8-57.9 -Fracture zone,very closely spaced joints,heavy iron oxide stainin9,carbonate. 70.6-84.2 -Joints closely to moderately closely spaced,iron oxide staining,carbonate coating. 62.5-70.6 -Fracture zone,very closely spaced joints,at 10 0 and 60 0 ,heavy iron oxide staining,some carbonate coating. 78.1-78.5 -Fracture zone,joints very closely spaced,at 30 0 •Slightly to moderately weathered,friable in places,silty/sand coating on most joint surfaces. 80.5-81.3 -Fracture zone,very closely spaced joints,iron oxide staining,carbonate. 80.9 -Joint,8 0 ,possible sliCkensides. 84.2-112.0 -Joints closely spaced,iron oxide staining and carbonate coating. Andes ite Porphyry 60 (50.9) 70 (59.4) 80 (67.8) .,J ~!, )).j -1 '1 ----,~-l ~~-l '»-'-")·-------1 :"")_o__~")"-1 "]-,"",--1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.5 OF 31 PROJECT Sus itna Hydroe1 ectri c Proj ecr SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.6 OF 31 DEPTH (FTI ROCK TYPE DESCRIPTION:COLOR,TExTURE,FOLIATlON,JOINTI NG,FRACTURING,fAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.) REC (ROO) DEPTH (FT)ROCK TYPE OESCRIPTION :COLOR I TEXTURE,fOLiATION,JOINTiNG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAYI NG,LO.ST CORE,CEMENTI NG,ETC. LENGTH OF RUN (FT) REe (RQD) 77 (0) 94 (32) 100 (36) 88 (21 ) 100 (79) 100 (92) 100 (98) Run 38 175.0 to 180.0 Run 37 170.0 to 175.0 Run 35 160.1 to 165.2 Run 36 165.2 to 170.0 Run 32 Run 33 150.6 to 155.8 Run 34 155.8 to 160.1 ~ 163.3 -Joint,30°,with clay coating. 153.2-153.6 -Healed shear,20°,joints very closely spaced,healed with dark green fine grained diorite. 154.7-160.1 -Shear/fracture zone,joints very closely spaced at 20°-60°.Slightly altered I I I hydrothermally,iron oxide staining and carbonate coating. 157.7 -Gouge,0.1 inches wide. 165.2-205.8 -Joints close to very closely spaced,iron oxide staining,carbonate and chlorite coating. 165.2-175.4 -Fracture/alteration zone, slightly to moderately weathered/altered hydrothermally,joints very closely spaced. Hard to moderately hard,iron oxide staining below 171.5. 165.2-165.7 -Clay on most joints. 169.0-169.5 -Shear/alteration lone, severely to completely altered hydro- thermally,soft and friable. 160.1-165.2 -No iron oxide staining. Diorite 180 (]52.6 170 (144.2 160 (135.7) 150(127.2 f 84 (0) 96 (51) 100 (98) 100 (94) 100 (89) 100 (86) 85 (49) Run 31 140.5 to 145.5 Run 32 145.5 to 150.6 Run 30 135.3 to 140.5 Run 29 130.1 to 135.3 Run 28 124.8 to 130.1 un 26 115.1 to 119.8 I Run 27 11 9.8 to 124.8 139.0 -Joint,10°with calcareous clay coating,some moderate hydrothermal alteration 1.0 inch on either side.Feldspars altering to clay. 143.8 -Joint,30°,moderately altered hydro- thermally,0.25 inches on either side of joint. 137.9 -Joint,40°,carbonate/calcite. 112.0 -Sharp contact with very thin stringers of andesite penetrating the diorite.Joint at contact,70°,with a trace of silt coating. Penetrative iron staining for 0.5 feet, slightly weathered. 112.0-126.1 -Joints close to very closely spaced,with iron oxide staining. 113.8-115.1 -Fracture zone,joints very closely spaced at 30°and 50°. 116.0 -Fracture,10°,tight,healed with calcite.0.25 inches wide,discontinuous, contains small fragments of diorite. 118.2-126.1 -Shear/fracture zone,joints very closely spaced,slightly to moderately weathered.Core loss 1.3 feet. 122.9-124.8 -Shear,gouge and breccia, friable. 126.1-160.1 -Joints close to moderately closely spaced,generally 1.0 to 2.0 feet. Iron oxide staining,carbonate and chlorite present. 134.0 -Inclusion of dark green,fine grained diorite,1.0 inch. Di orite 140 (118.7) 130 (11 O.2) 120 (101.8) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY JOB NO P5700.05 CLIENT ALAS KA POl,ER AUTHOR ITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 PROJECT Sus itna Hydroel ectri c Proj ect HOLE NO.BH-4 SITE Watana (North Bank)SHEET NO.7 OF 31 SITE Watana (North Bank)SHEET NO.8 OF 31 DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FCLIATION,,JOI NTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (Ft) AEC (RQD) DEPTH (FTJ ROCK TYPE DESCRiPTION:COLOR,TEXTURE,FOUAT10N,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN I CAVING,LOST CORE,CEMENTI NG,ETC. LENGTH OF RUN (fT.) AEC (ROD) 190 (16].1) Diorite 181.8-184.2 -Fracture zone,joints are very closely spaced,at 10°and 40°_60°. 187.2 -Joint,70°,with slickensides at 80°. 188.5 -Joint,50°,with slickensides at 0°. 189.3 -End of iron oxide staining,trace amounts below this depth,carbonate coating on joints. Run 39 180.0 to 185.0 Run 40 185.0 to 190.1 Run 41 190.1 to 195.0 100 (22 ) 100 (90) 100 (88) 220 (186.6) Di orite Run 46 210.7 to 215.7 Run 47 215.7 to 220.8 Run 48 220.8 to 225.8 100 (100) 100 (100) 100 (100) 100 (90) 100 (94) 100 (100) 100 (100) Run 52 240.8 to 245.8 Run 50 230.8 to 235.8 Run 51 235.8 to 240.8 Run 49 225.8 to 230.8 zone,joints Chlorite and 0.1 inches thick,I I ~ 234.8-236.4 -Shear/fracture very closely spaced,at 20°, carbonate coating,less than s1ic kens ides. 240 (203.5) 230 (1 95.0) 88 (RR) 100 (88) 100 (65) 100 (48) 100 (100) Run 45 205.8 to 210.7 Run 46 Run 42 195.0 to 200.0 Run 43 200.0 to 204.0 I Iat10°.~un 44 0.1 204.0- ?n~R 195.5 -Joint,15°,with clay filling 0.1 inches wide. 199.7-200.1 -Core is broken,sandy clay coating. 204.4-205.4 -Shear along three joints, Slickensides on chlorite and carbonate, inches wide. 205.8-375.6 -Joints are moderately close to widely spaced,with a few zones of closely spaced.Trace of carbonate. 209.3-210.7 -Joints closely spaced. 229.8-231.8 -Joints closely spaced. 200 (169.6) 210 (178.1) 1,j ~"';\~~~~'i l\.~J 1 0 1 ]1 J 'I ~j':j )~"l '"1 -""]-'"-,"---1 '--J 1 ,--rl --J ___-_) '}~I ])) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4- SHEET NO.1 0 'lF31 100 (100) Run 61 285.8 I 100 to (100) 290.7 Run 62 290.7 [100 to (100) 295.8 LENGTH I RECOFRUN (FT)(ROO) --- Run 59 275.8 1100to(100) 280.8 Run 60 280.8 I 100to(100) 285.8 ~~U6 to 310.8 Run 63 295.8 I 100 to (84) 298.9 Run 65 300.8 1100 to (100) 305.8 Run 64 298.9-100 300.8 95 DESCRJPTJ ON;COLOR,TEXTURE,FOLIATION,JOI NTING,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS ORGAIN,CAVING,LQST CORE,CEMENTING,ETC 279.8 -Carbonate vein,30°-40°,0.1 inches wide. 289.4 -Healed shear,10°,0.1 inches wide, healed with carbonate,tight,hard. 289.5 -Joint,10°with slickensides on carbonate and chlorite coating. 291.0 -Healed shear,10°,less than 0.1 inches thick,carbon~tp.filled,tight,hard. 306.0-307.9 '( 314.2-314.6 )Red intergranular stain on the diorite. ROCK TYPE ALASKA POWER AUTHORITY Di orite CLIENT DEPTH (FTJ 290 (245.9 280 (237.4) 300 (254.4) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DR IL LIN G REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 SITE Watana (North Bank)SHEET NO.9 OF 31 DEPTH DESCRIPTION:COLOR,TEXTURE.FOLIATION ,JOI NT1NG,FRACTURING,FAULT]NG,LENGTH REC ROCK TYPE OF RUN(FT.)ALTERATION,WATER LOSS OR GAIN I CAVI NO,LOST CORE.CEMENTING I ETC.1FT)(ROO) Diorite Run 52 247.1 -Felsic vein,90°,light gray,less Run 53than0.25 inches wide,tight,hard. 245.8 100 to (100) 250 251.0 (212.0) Run 54 251.0 100 to (100) 255.7 Run 55 255.7 100 to (100) 260 260.8 (220.5)-- Run 56 260.8 100 to (100) 265.8 Run 57 265.8 100 to (100) 270.8 270 (229.0) Run 58 270.8 100 to (100) 275.8 Run 59 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.11 OF 31 SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.12 OF 31 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION 1 JOINTING,FRACTURING,FAULTI NG,~~N~G~REe ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FT)(RQD) DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOI NTING,FRACTURING,FAULTI NG,~~N~G~REC ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (nj (RQO) Run 79 370.5-1 100 375.6 (100) 370.0-370.5 -Core broken by drilling. Run 78 367.7 -Heal ed fracture,0.1 inches wide,I 4 regular,discontinuous,healed with carbonate.3~~. 370.5 310 (262.9) 320 (271.4) 330 (279.8) 340 (288.3) Diorite 316.2 -Healed breccia,20 0 ,0.1 feet wide, healed with dark green,fine grained igneous material,hard. 320.3-320.6 -Core broken by drilling,fresh, angular pieces,1.0 to 2.0 inches. 322.0-322.3 -Inclusion of fine grained,dark green diorite. 324.4-325.0 -Fractures healed with carbonate, irregular shape,discontinuous,up to 0.5 inches wide. 326.7-330.4 -Joint,00 _10 0 ,chlorite and carbonate coated,faint slickensides. 331.2-332.2 -Fracture zone,joints very closely spaced at 00 _30 0 ,some surfaces altered hydrotherma lly. Run 66 Run 67 310.8 to 315.8 Run 68 315.8 to 320.8 Run 69 320.8 to 325.8 Run 70 325.8 to 330.8 Run 71 330.8 to 335.8 Run 72 335.8 to 340.8 100 (100) 100 (96) 100 (100) 100 (100) 100 (100) 100 (100) 350 (296.8) 360 (305.3) 370 (313.8) Diorite 343.7-343.8 -Fracture zone,up to 0.1 inches wide,irre9ular,discontinuous,healed by calcite/carbonate,tight,hard. 344.0 -Healed shear,30 0 ,healed by dark green,fine grained igneous material,tight, hard. 355.8 -Fracture,filled with carbonate,dis- continuous,0.25 inches wide. 356.5-357.7 -Fractures,00 _10 0 ,healed with carbonate less than 0.1 inches thick. 361.0 ? 366.0J Healed shears,15 0 ,less than or equal to 0.25 inches wide.Healed with dark green,fine grained diorite,hard. Run 73 ~40.8 to 45.7 Run 74 b45.7 to 350.7 Run 75 350.7 to 355.6 Run 76 355.6 to 360.2 Run 77 360.2 to 365.4 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) J 1 j ,1 ~f )~~J ~-"'1 ]""'""'-~._-'."'0')'.']~]1 I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) JOB NO.P5700.05 LENGTH I RECOFRUN (FT)(RQO) ---- Run 86 405.5 1 100 to (100) 410.4 Run 88 415.7 I 100 to (100) 420.7 -- Run 89 420.7 I 100 to (100) 425.7 -- Run 90 425.7 I 100 to (100) 430.9 Run 91 430.91 100 to (100) 435.8 Run 92 Run 87 410.4 I 98 to (98) 415.7 HOLE NO.BH-4 SHEET NO.14 OF 31 DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTI NG,ETC 416.5-416.8 -Healed breccia,50 0 ,diorite inclusions up to 2.0 inches in dark green, fine grained diorite. 417.7-418.6 -Healed breccia,diorite frag- ments up to 2.0,inches and comprise 70-80%of the rock.Healed with a dark green,fine grained diorite,hard,tight. 419.3-419.8 -Fracture lone,joints very closely spaced at 60°,carbonate filling, tight healed joints. 420.8 -Felsic vein,15 0 ,less than 0.25 inches wide,tight. 423.9-510.4 -Joints close to moderately closely spaced,average 1.0 foot.Trace to coating of carbonate and chlorite. 426.0 -Joint,10°with faint slickensides on chlorite.Felsic vein,15°,light gray,fine grained,chilled contact,tight,hard. 429.2 -Joint,60 0 with faint slickensides. 429.5 -Joint,10°,with slickensides on chlorite. 429.8 -Joint,55°,with slickensides on chlorite at 40 0 • 405.2 -Healed breccia along a joint at 10 0 - 200 ,approximately 1.0 inches wide.Healed with dark green,fine grained diorite. ROCI(TYPE Di orite DEPTH (FT.) 430 (364.6 420 (356.2) 410 , (347.7) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUfFALO.NEW YORK DRILLING REPORT CLIENT ALASKA PO,IER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 SITE Watana (North Bank)SHEET NO.13 OF 31 DEPTH DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG,LENGTH REC ROCI(TYPE OF RUN {FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FT)[RQD) Oiorite 373.0-373.2 -Felsic dike,white-yellow to Run 79 gray,10-20%quart~1.0 to 2.0 inches wide.370.5 100 Contacts are hard,tight,and irregular.to (100) 375.6 375.6-423.9 -Joints are moderately closely spaced,average 2.0 feet,generally trace of Run 80 carbonate and/or chlorite.375.6 100 378.5 -Joint,20°,trace of silt/clay.to (100) 380.6 380 (322.2) Run 81 380.6 100 to (100) 385.6 Run 82 385.6 100 to (100) 390.7 d3%~7 392.4-393.2 -Healed breccia along several Run 83 joints at 0°and 15 0 •Healed with dark green,390.7 100finegraineddiorite,tight,hard.to (94) 395.4-395.7 -Carbonate vein,10 0 ,up to 0.25 395.5 inches wi de. Run 84 395.5 100 to (100) 400.6 400 (339.2) Run 85 400.6 100 c to (98) 405.5 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroel ectric Project SITE Watana (North Bank) HOLE NO.B'H-4 SHEET NO.15 OF 31 SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.16 OF 31 DEPTH· (FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,..JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,wATER LO~5 OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC. LENCTH I REC OF RUN (RQO)(Ft) DEPTH (FTJ ROCK TYP( OESCRIPTI ON :COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAU LTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC LENGTH OF RUN (FT.) REC (ROD) 100 (98) 93 (93 ) 100 (94) 100 (100) 100 (100) 100 (100) 100 (100) Run 102 485.7 to 490.6 Run 103 490.6 to 495.6 Run 100 475.8 to 480.8 465.4 -Shear along joint at 40°,slickensides,IRun 98 0.1 inches thick gouge. 465.6 -Felsic dike,light gray,fine grained, possibly granodiorite,approximately 2.0 inchesiun 99 wide at 40°,tight contacts.Part of dike is 4708 crosscut by the above shear.to' 475.8 489.2 -Healed shear,30°,0.75 inches wide, healed with dark green,fine grained diorite. 490.1 -Healed shear as above,40°,1.0 inch wide. Run 104 ~495.6 100 497.3-499.0 -Inclusion or dike of fine to (100) grained,dark green diorite,sharp contacts at ~49~8~.~0=+--j 40°,tight,hard.Run 105 498.0 to 500.8 Run 101 483.3 -Joint,10°,possible faint slicken-1480.8 sides on chlorite.to 485.7 Oi orite 500 (424.0)! 490 (415.5) 480 (407.0) 470 (39B.6) 100 (98) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) Run 98 465.9 to 470.8 Run 97 460.8 to 465.9 Run 96 455.8 to 460.8 Run 95 450.8 to 455.8 Run 92 435.8 to 440.8 Run 93 440.8 to 445.8 Run 94 445.8 to 450.8 462.0-463.5 -Alteration zone,slightly altered hydrothermally,diorite bleached to light gray-green,hard. 464.0 -Joint,20°,faint slickensides on chlorite.Crosscut joint at 30°,faint slickensides on chlorite. 458.2-458.6 -Fracture zone,joints very closely spaced at 30°,healed with carbonate. 430.7 -Joint,10°,0.25 inches thick,healed with carbonate,tight.Crosscutting joint, 10°,coated with talc/chlorite and carbonate, possible slickensides. 430.9-439.2 -Joints/fractures 0°_10°and 30°-1---I I 50°,very closely spaced,irregular and discontinuous.Healed by carbonate and sulfides,generally moderately hard with some zones of friable rock,tight. 444.5 -Healed shear,30°,0.25 to 0.5 inches wide.Healed with dark green,fine grained diorite. 445.0-448.0 -Andesite dike,50°,medium gray-green,aphanitic rock with approximately 10%phenocrysts of carbonate up to 0.1 inches, parallel to flow structures.Fresh,hard, unfractured,contacts tight. 450.2-455.2 -Felsic dikes,four,20°_30°, fine grained,composition is probably close to a granodiorite.Moderately closely spaced, 1.0 to 2.0 inches wide,hard,tight contacts. Oiorite 440 (373.1) 450 (381.6) 460 (390.1) 1 ~~~'~~1 ]1 fi ;~.~ '"j!.,I ,j j ---1 '-"--'1 ~')--1 ~--"J -~-~1 1 ---J ,.-----1 ,c____-',--1 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO t NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 PROJECT SUS itna Hydroel ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO,BH-4 SHEET NO,17 OF 31 SITE Watana (North Bank) HOLE NO,BH-4 SHEET NO.18 OF 31 DEPTH {FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLlATION ,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT.l REG (ROD) DEPTH (FT.)ROCK TYPE ~:COLOR,TEXTURE,F'OLIATION,JOINTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. LENGTH OF RUN (FT.) REC (ROD) 100 (65) 100 (100) 100 (100) Run 112 530.7 to 535.8 Run 113 535.8 to 540.7 Run 114 540.7 to 545.9 537.1 -Shear along joint,20 0 ,0.5 inches of breccia and gouge,slickensides on chlorite. 537.7 -Joint,30 0 ,slickensides on chlorite. 538.3-538.9 -Numerous healed fractures, irregular,discontinuous.Healed with calcite/carbonate,up to 0.25 inches wide. 539.1-541.2 -Felsic lenses and dikes,light gray,fine to medium grained.Felsic material comprises 50%of rock,tight contacts,hard. 543.7-548.9 -Alteration zone,bleached yellowish-white,hydrothermally altered.No mafics,feldspars altering to clay,moderately I--I I hard to soft.ROD =0%. Di orite _540 _ (457.4) 100 (1 DO) 100 (100) 100 (100) un 108 510.7 to 515.8 I<un 107 505.8 to 510.7 502.6-503.0 -Felsic dike,light gray,fine run 106 grained,probably granodiorite.Upper contact 5008 fractured,lower contact tight at 70 0 •Hard,to' unfractured.505.8 510.4-627.8 -Joints moderately close to widely spaced,trace of chlorite and carbonate I I ----1 coating. Diorite 510 (432.5) un 112 530.7-1 100 535.8 (100) un 111 525.61 100 to (100) 530.7 fun 11 0 520.5 1100 to (96) 525.6 520 (441.0) 530 (449.4 523.5-525.1 -Zones of joints very closely spaced,at 20 0 _30 0 ,healed with carbonate. 524.3 -Healed shear,30 0 ,1.0 inch wide, healed with dark green,fine grained diorite. 526.5-527.6 -Textural and mineralogical changes.Medium to fine grained,less than 15%mafics.Hard,sharp,tight contacts. un 109 515.8 to 520.5 100 (100) I 550 (466.4) 560 (474.9) 553.0-553.5 -Felsic dikes,three,80 0 -90 0 , closely spaced,less than 0.5 inches,hard, tight. 559.7 -Healed shear,30 0 ,1.5 inches wide. Healed with dark green,fine grained diorite, hard. 560.5-561.2 -Red staining on core. Run 115 545.9 to 550.8 Run 116 550.8 to 555.8 Run 117 555.8 to 560.8 Run 118 560.8 to 565.8 100 (43) 100 (100) 100 (100) 100 (100) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susi tna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.19 OF 31 SITE Watana (North Bank) HOLE NO BH-4 SHEET NO.20 OF 31 DEf'TH (FT)ROCK TYPE DESCRIPTION;COLOR,TEXTURE,FOLIATION ,..JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN I CAYI NG,LOST CORE,CEMENTI NG,ETC LENGTH OF RUN (Fl) REC (ROD) DEPTH (FT.)ROCK TYPE DEseRI prl o~:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAYI NG,LOST CORE,CEMENTI NG I ETC. LENGTH OF RUN (FT) ReG \RQOJ Run 118 100 (100) 100 (100) Run 126 600.7 to 605.7 1--.--1-------1 597.0 -Felsic dike,80',light orange,0.5 inches wide.Truncated by healed shear at 40''IRun 125 597.9 -Inclusion of dark 9reen,fine grained 595.8 diorite,diameter of 1.0 inch.to600.7 Di orite 600 (508.8) 100 (50) 100 (100) Run 120 570.9 to 575.9 fun 119 565.8 to 570.9 567.7 -Felsic dike,90 0 ,li9ht gray,medium to coarse grained,unfractured,0.1 feet wide, tight contacts,hard. 569.3 -Joint,00 _20.,carbonate healed,sligh~ hydrothermal alteration up to 1.0 inch. 571.7-574.9 -Alteration zone,bleached to yellow-white,moderately to severely altered hydrothermally.Feldspars altered to clay,no mafi cs,moderately hard to soft,1oca lly friable.RQD =0%. Di orite 570 (483.4) Run 123 585.81 100 to (100) 590.8 Run 12 590.81 100 to (100) 595.8 Run 12~ Run 129 615.71 100 to (59) 620.8 100 (88) 100 (15) 100 (80) 100 (100) Run 127 605.7 to 610.7 Run 121 610.7 to 615.7 Run 130 620.8 to 625.9 Run 131 625.9 to 630.9 627.8-710.2 -Joints close to moderately closely spaced,chlorite coated with trace to coatin9 of carbonate. 610.9-618.3 -Shear/alteration zone,bleached to a light yellow-9ray,slightly to moderately I I altered hydrothermally with zones of severe alteration.Feldspars altered to clay, moderately hard to soft,biotite crystals close to altered zone. 612.1-618.3 -Shear,0',0.5 inches wide, partially healed with carbonate and chlorite.Alteration is more intense on one side than the other. 620.1-622.2 -Shear,10',partially healed by carbonate,up to 0.5 inches wide. 620 (525.8) 610 (517.3) 100 (100) 100 (100) Run 121 575.9 to 580.8 Run 122 580.8 to 585.8 588.5 -Healed shear,30·,healed with carbonate less than 0.1 inches wide.Healed with dark green diorite,tight. 588.8-588.9 -Fracture zone,fractures very closely spaced,healed with carbonate,dis- continuous,irregular,hard. 591.0 -Healed shear,30',0.25 inches wide, healed with dark green diorite and carbonate, tight. 578.0-578.8 -Healed shears,closely spaced, healed by dark green,fine grained igneous material,hard. 578.5 -Possible offset of felsic dike, 1.0 inch wide.Offset up to 0.5 inches. 590 (500.3 ) 580 '(491.8) ]u 1 ,"~3 ~M ~~~1-'~ ';1 J ~J ,J c,~"l -'"J "~~'J ~)1 ]"]"""1 ~.-')"],'-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO 1 NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO 1 NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.21 OF 31 SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.22 OF 31 DEPTH (FT.l ROCK TYPE DESCRIPTION;COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTl NG, ALTERATION,WATER LDSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC, LENGTH OF RUN (FT.) REG (ROD) DEPTH {FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,!-OST CORE,CEMENTING,ETC. LENGTH REC OF RUN (ROD](FT.) Run 141 ,. Run 139 665.71 100 to (96) 670.7 Run 140 670.71 100 to (98) 675.7 Run 138 660.7 1100 to (66) 665.7 669.7-670.7 -Joints,10 0 ,0.5 inches wide, healed with carbonate.Irregular fractures, discontinuous,healed with carbonate. 671.4-672.3 -Red stain on core. 672.8 -Joint,30 0 ,0.25 inches wide,healed with carbonate. 673.6-678.6 -Shear,00 _10 0 ,partially healed by carbonate and chlorite.Slickensides,thin coating of gouge less than 0.1 inches. 666.8 -Diorite breccia,0.5 inches wide, healed with carbonate,irregular,tight. Oi orite 670 (568.2) 100 (88) 100 (70) 100 (30) 100 (45) Run 131 Run 132 630.9 to 635.9 Run 133 635.9 to 640.8 Run 134 640.8 to 645.8 642.4 -Joint,10 0 ,slickensides on chlorite. 629.3 -Shear,10 0 ,0.25 to 0.5 inches wide, partially healed by carbonate. 635.9-637.5 -Fracture zone,joints and fractures very closely spaced,up to 0.1 inche wide.Healed with carbonate,discontinuous,I I I irregular. 632.5 -Joint,10 0 ,partially healed by carbonate.Slickensides on chlorite. 644.1-644.8 -Fracture zone,joints very closely spaced,at 60 0 • Diorite 640 (542.7) 630 , (534.2) Run 137 655.81 100 to (100) 660.7 100 (67) 100 (100) 100 (100) 675.7 to 680.8 Run 14 680.8 to 685.7 I---+I-----j Run 143 685.7 to 690.8 691.7-691.9 -Felsic dike,30 0 ,light green- gray,medium grained.Up to 10%quartz,5-10%Run 14 -- mafics.Tight,welded contacts,fractured and 690.8 100 healed with carbonate,hard.695.8 (100) 690 _ (585.1) 680 (576.6) 100 (70) 100 (85) Run 136 650.8 to 655.8 Run 135 645.8 to 650.8 648.0-648.7 -Healed breccia,fragments of diorite comprise 70-80%,healed by dark green diorite.Hard,joint at 20 0 at upper contact, healed with carbonate,approximately 0.25 inches wide. 649.4-649.8 -Joints,50 0 -70 0 ,very closely spaced,tight. 660 (559.7 650 (551.2) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFA LO ,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.23 OF 31 SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.24 OF 31 DEPTH (FT.l ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN I CAVING,LOST CORE,CE:MENTI NG,ETC. LENGTH OF RUN (fT.) AEe (RQO) DEPTH (FT)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,fOLIATION ,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETG. LENGTH OF RUN (FT) REG (RQO] Run 150 720.81 98 to (56) 725.8 Run 15 755.9-768.8 -Joints are close to moderately closely spaced. 100 (16) 100 (60) 100 (35) Run 155 745.8 to 750.8 Run 154 740.8 to 745.8 Run 151 725.81 100 to (15) 730.8 Run 152 730.81 100 to (30) 735.8 Run 156 750.8 to 755.9 Run 153 735.81 100 to (30) 740.8 Run 150198(56) 1 1--- 749.4-755.0 -Fracture zone,joints and fractures very closely spaced,mostly tight, randomly oriented.Joints at 00 _10 0 ,and 60 0 ,less than half are healed with carbonate.I 1 ----l 752.8-755.0 -Core broken along the 60 0 joint set. 726.1-730.9 -Shear/fracture zone,joints very close to closely spaced,oriented at 30 0 and 10 0 •Numerous irregular fractures,some carbonate healed.Slickensides. 732.5 -Joint,10 0 ,with slickensides on chlorite. 742.3-743.2 -Fracture zone,joints very closely spaced at 70 0 • 734.6-738.0 -Shear/fracture zone,numerous joints very closely spaced,at 30 0 •Some healed with carbonate,up to 0.25 inches thick,tight. 736.4 -Joint,20 0 ,slickensides on chlorite. 738.3-739.5 -Joints,70 0 ,closely spaced. Oi orite 750 (636.0 740 (627.5) 730 (619.0) 100 (36) 100 (90) 100 (90) 100 (100) 100 (100 ) 100 (100) Run 149 715.8 to 720.8 Run 147 705.7 to 710.8 Run 145 695.8 to 700.8 Run 148 710.8 to 715.8 Run 144 690.8 to 695.8 Run 146 700.8 to 705.7 723.3 -Joint,20 0 ,trace of silty sand. 720.1-721.1 -Fracture zone,joints very closely spaced,at 40 0 _70°. 698.7-700.4 -Shear,10 0 ,partially healed with carbonate,chlorite.Faint slickensides. 701.4-703.1 -Numerous healed fractures, closely to very closely spaced,up to 0.25 inches thick.Healed with carbonate, irregular,discontinuous. 710.2-710.8 -Fracture zone,joints and fractures very closely spaced,angular pieces 0.5 to 1.0 inch,most surfaces stained. 710.2-755.9 -Joints closely spaced with zones of very closely spaced.Generally a coating of chlorite and a trace to coating of carbonat~. 712.0-713.5 -Fracture zone,joints very closely spaced,at 20°and 60°.Joints at 20 0 are hea}ed with carbonate. 692.8-693.3 -Pods of felsic material similar to above dike.Irregular shapes up to 1.0 inch,hard. 693.9 -Inclusion of dark green,fine grained diorite,2.0 inches long. Diorite 720 (610.6) 700 (593.6) 710 (602.1) 'If 4 J;1 11 )n J J ,j.l i ~]--J .._-]-J '--1 -_.)],1 J --1 l ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK D R I L LI NG R E PO R T CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.25 OF 31 SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.26 OF 31 DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,fOLIATION,,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER L.OSS OR GAIN,CAVING1 LOST CORE,CEMENTING I ETC. LENGTH OF -RUN (FT.) REC {ROD) DEPTH {FTJ ROCK TYPE DESCRIPTION:COLOR.TEXTURE,FOLIATlON,JOINTlNG,FRACTURING,FAULTI NG I ALTERATION.WATER LOSS OR G41N,CAVING,l:.OST CORE,CEMENTING.ETC LENGTH OF RUN (FT) REC [RQD] Run 159 768.B-77l.2 -Fracture zone,joints very 17~~.B 1 100 I ~800 closely spaced,at 0°_10°,some are healed (65){679.l by carbonate.770.9 768.8-786.2 -Joints close to very closely spaced. Run 1601 770.9 100 to (16) 775.9 -- IRun 161 I775.91 100 ~810to(58)(686.9 780.9 780.0 -Joint,15°,slickensides on chlorite, trace of yellow sandy silt. !Run 162 783.7 -Joint,15°,trace of silt or clay.780.9 I 100 to (50) 785.9 786.2-850.5 -Joints close to moderately Run 163closelyspaced,average 0.5 to 1.0 foot. Chlorite coatin9,trace to coating of 785.91 100 carbonate.to (90)I ~820790.9 (695.4 1-----1----1 Run 1631 100 (90) Run 165 795.81 100 to (75) 800.7 100 (88) 100 (32) 100 (41 ) 805.6 to 810.7 Run 169 815.8 to 820.8 Run 164 790.9 I 100 to (59) 795.8 Run 166 800.7 I 100 to (69) 805.6 Run 168 810.7 to 815.8 797.1 -Inclusion of fine grained diorite, diameter 1.0 inch. 797.8-798.1 -Fracture zone,joints very closely spaced at 70°.Carbonate,chlorite coating,possibly some talc. 803.0-Healed shear,lOa,healed with fine grained felsic material,tight.Offset of 0.5 inches along inclusion of fine grained diorite. 804.1-805.3 -Fracture zone,joints/fractures very closely spaced,at 0°_10°,and 40°,IRun 167 most healed with carbonate,broken by drilling. 805.2-806.2 -Healed shear,10°,1.0 inch wide fragments of diorite,healed by dark green diorite,tight,hard. 811.9-820.5 -Textural changes in diorite, light gray-green,medium to coarse grained, less than 10%mafics. 812.0-815.8 -Shear/fracture zone,joints very closely spaced at 10°and 60°.8roken by drilling,pieces 0.5 to 2.0 inches,coated with silt or clay.Most joints are tight, minor sulfide mineralization. 813.5 -Breccia,1.0 inch wide,partially healed with carbonate. Diorite790 (669.9 Run 158 760.91 100 to (80) 765.8 Run 157 755.91 100 to (94) 760.9 758.5-759.8 -Healed shear,lOa,healed with dark 9reen diorite and carbonate,tight. Oiorite 780 (661.4) 770 (623.0) 760 (644.5) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHOR ITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.8H-4 SHEET NO.27 OF 31 SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.28 OF 31 DEf'TH (FT)ROCK T'l'PE DESCRIPTI ~:COLOR,TEXTURE,FOLIATION ,.JOINTING,FRACTURING,FAULTI NG. ALTERATiON I WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC. LENGTH OF RUN (FT.) REe (~QDJ DEPTH (FT.)ROCK TYPE OESCRIPTION COLOR,TEXTURE,FOLIATION I JOINTING,FRACTURING,FAUL.TI NG t ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. LENGTH OF RUN (FT.) RE,C [RQO) 100 (92) 100 (80) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) Run 182 880.6 to 885.6 Run 179 865.5 to 870.6 Run 181 875.6 to 880.6 Run 178 860.5 to 865.5 Run 177 855.6 to 860.5 Run 180 870.6 to 875.6 IRun 176 850.5 to 855.6 f----+--- 870.3-871.0 -Fracture zone,joints very closely spaced at 60°. 858.1-869.9 -Diorite changes to light green- gray,10-20%mafics. 859.6-866.6 -Fracture zone,joints and fractures very closely spaced,oriented at 30°and 70°.Mostly tight,less than 25% healed with carbonate. 873.0-875.2 -Shear/alteration zone,core bleached to a light yellow-green,slightly to moderately altered hydrothermally.Hard to medium hard,joints/fractures very closely spaced,tight,generally healed with carbonater-----~-i 875.0 -Shear,60°,healed with carbonate, breccia,0.1 feet. 877.5 -Inclusion of dark green,fine grained diorite,1.5 inches in diameter. 878.8 -Joint,30°,trace of clay. Di orite 880 (746.2) 860 (729.3) 870 (737.8) 100 (85) 100 (40) 100 (60) 100 (80) 100 (94) 100 (100) Run 17E 850.5\100 to (100) R'i'i Ii Run 1751 845.7 to 850.5 Run 174 840.8 to 845.7 Run 171 825.8 to 830.8 Run 170 820.8 to 825.8 Run 172 830.8 to 835.8 828.8 -Joint,80°,faint slickensides on chlorite. 825.3-825.9 -Core is broken by drilling, minor sulfide mineralization on broken surfaces. 834.5-835.8 -Fracture zone,joints/fractures very closely spaced,at 0°_10°and 40°-60°, irregular,healed to partially healed by carbonate.Joint/shear,0°,offset O.1 inches.~--+------~ 837.8 _Joint,50°,possible slickensides.IRun 173 835.8 to 840.8 850.5-896.0 -Joints moderately closely spaced,chlorite coating,trace to coating of carbonate. Di orite 830 (703.8 840 (712.3 850 (720.8 11 .~1-~1 Th 3 .~ "i \1 :1,cJ '~~-J ······1 J "-1 c~-l ··..·~·l .]C'-l "--1 -1 --J '-1 .....J I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.29 OF 31 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.30 OF 31 DEPTH (FT)ROCK TYPE OESCRIPTI ON:COLOR I TEXTURE,FOLIATlON,JOINTlNG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. LENGTH I REC OF RUN (RQD)(FT.) DEPTH (FT.l ROCK TYPE DESCRIPTION:COLOR I TEXTURE,FOLlATION,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,Lo.ST CORE,CEMENTING.ETC LENGTH OF RUN (FT) REC (RQD) 96 (96) 100 (98) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) Run 1951 944.4 to 949.6 Run 192 930.3 to 935.4 Run 190 920.6 to 925.7 Run 1931 935.4 to 939.3 Run 189 915.6 to 920.6 Run 191 925.7 to 930.3 Run 194 939.3 to 944.4 939.3-939.4 -Fragments,two,of andesite porphyry,probably fell in hole during bit change. 913.5-939.0 -Healed shear zone,numerous shears very closely spaced,healed by dark green diorite,hard,competent.Felsic dikes within shear are light gray,fine grained,up to 1.0 inch wide,offset along healed shear planes up to 1.0 inch.Approximately 50-75% of zone is healed shears,approximately 5%of the shear zone is felsic dikes. Di orite 940 (797.1) 920 (780.2) 930 (788.6) 100 (98) 100 (45) 100 (100) 100 (100) 100 (100) 100 (100) 100 (100) Run 18 Run 185 895.6 to 900.6 Run 187 905.6 to 910.6 Run 184 890.6 to 895.6 Run 186 900.6 to 905.6 healed fractures/joints~R~ullin--u8~2~1 10%of rock.Joints, i rregul ar and Run 183 885.6 to 890.6 902.4 -Inclusion of dark green,fine grained diorite. 903.0-903,2 -Inclusion or dike of dark green diorite,sharp contact at 45°. 904.5 -Joint,80°,clay and carbonate coating Run 188 909.1 -Felsic dike,50°,light gray,medium 910.6 grained,0.5 inches wide,unfractured,tight to contact.915.6 909.5-910.5 -Healed shear,0°_10°,healed with dark green,fine grained diorite. 883.5-884.5 -Numerous healed with carbonate, 20°_30°,fractures are discontinuous. 890.6-895.7 -Shear/alteration zone,core is bleached to a light yellow-green,generally slightly altered hydrothermally.Generally hard except for the following zones: 891.7 -Healed shear,50°,crosscut by a joint with clay fillings less than 0.1 inches wide. 893.0-895.1 -Moderately altered hydro- thermally,moderately hard to soft, locally friable. 893.1 -Shear,15°,1.0 to 2.0 inches of breccia,partially healed by carbonate. 893.3-893.4 -Broken fragments of breccia. 893.8-894.1 -Fragments of altered dioritel I I and breccia,pieces less than 1.0 inch. 895.1 -Shear,30°,1.0 inch wide,breccia and gouge healed with carbonate. 896.0-949.6 -Joints moderately close to wide, chlorite coating,trace to coating of carbonate. 898.9-899.8 -Joints,30°and 70°,very closely spaced,healed with carbonate to 0.1 inches. Di orite 910 (771 .7) 900 (763.2) 890 (754.7) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-4 SHEET NO.31 OF 31 DEPTH (FT.)ROCK TYPE OESeRI PTI ON:COLOR,TEXTURE,FOLIATlON,JOINTING,FRACTURING,FAULTI NG, ALTERATION,wATE:R LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RllN tFT) REO (RQD) _949~Oiorite I END OF BORING--IRun 195 1 I 11 805 .3 ) ~,1 '\'~.,~ !:r 1 jl -1 ---1 '~'-l 1 "J --~"i ""'-~l ']---1 '1 --.--J ."-1 ')--1 -, 1 Acres American Incorporated -Consulting Engineers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG SUMMARY LOG Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana (North Bank) Job No.P5700.05 Hole No.,~-"B",H~-4"--_ Sheet No.~l_of .~3_ Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana (North Bank) Job No.P5700.05 Hole No.~-"B",H~-4-,--_ Sheet No .._2_of __3 _ REMARKS • Joints,slicken- sides. Fracture zone. Oike,mafic. Shear. Alteration zone. Alteration zone. Shear. Shear/alteration zone. Shear. ROCK TYPE Oiorite REMARKS • Fracture/alteration zone. Shear/fracture. Fracture zone. Fracture zone. Fracture zone. TOP OF ROCK 12.4' Shear/fracture. Shear/fracture zonp Shear/fracture. Fracture zone. Shear/fracture zone -Joint,slickensides on chlorite. ROCK TYPE ROO % PERMEABILITY I CORE RECOVERY (K)em/ue,% 10-6 lOA 10-2 60 I _ 20 I I I I I I 1 I 2061 40 I ~1 III I 1 80 +-----.J++++, 260 ~E:T~~I ~~~. 320 300 -160 140 I I11III1 I ++t-1 120 280 100+2103.11 1 II' 340 Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client_ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site_------'Latana (North B_ar1i<l _ Job No.P5700.05 Hole No.,_-=BccH_--'..4 _ Sheet No._3_of _3_ D(~~~I ~~~,~. - -720 740 760 780 ~~ 820 840 -860 880 900 - 920 940 960 ROCK TYPE 61-+++--1 Di 0 rite REMARKS Shear/fracture zone Fracture zone. Shear/fracture zone Fractu re zone. Shear/alteration zone. END OF BORING 949.6' • 'J 1 ''],.,~~'l 1 ~"1 1 1 1 '1 J 1 "J 1 I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT:ALASKA POWER AUTHORITY JOB NO.,P5700.05 PROJECT,Susitna Hydroelectric Project HOLE NO.,BH-6 SITE:Watana (North Bank)SHEET NO.1 OF 24 CONTRACT\lR,The Drilling Company ORILLING OATES',June 26 TO July 9,1981 LOGGEO BY,K.J.White,M.P.Bruen DATE,July 1981 REC (ROD) 83 (0) 97 (0) 100 (60) 100 (63) LENGTH OF RUN (FT.) Run 6 26.8 to 30.3 JOB NO.P5700.05 HOLE NO.BH-6 SHEET NO.2 OF 24 DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN ,CAVING,LO~T COREl CEMENTING,ETC 26.8-30.0 -Core loss 0.5 feet. 29.7-30.3 -Fracture zone,joints and fractureshR ~--JL-- very closely spaced,joints at 0°_10°and 3~n3 30'-40',slightly weathered.t~ ~?g DioritelJoints are very close to moderately close,with Run 4 iron oxide staining.19.6 17.1-26.8 -Fracture zone,joints and fractures'2~o8 very closely spaced,moderately to severely R ~5 I I weathered with penetrative iron oxide staining.2~8 Core loss 0.7 feet.t~ 26.0-64.3 -Fresh to slightly weathered,with 26.8 more intense weatheri,no on joints,iron oxide 1---+----1 staining.Joints closely to moderately closely spaced. ROCK TYPE Watana (North Bank) Quartz DEPTH (FTJ SITE PROJECT Susitna Hydroelectric Project CLIENT ALASKA PO\JER AUTHORITY 30 (26.0) % REC (RQO) CASING DIAMETER,NW (3.0")I.D. CORE DIAMETER:NQ (1.75")0.0. A.S.P.C.,Zone 4 1608.8 1601.9 967.6 1461.8 (12-06-80) OE:~~:AT~~I~~~~~~;~T~:S~U::{~;I~~~~N~~I~~~;~~~,T~~~~~~:~~T~:I LE~~~H Sandy gravel with cobbles and boulders. Casing Advancer Diamond Core -Triple Tube N3,226,922 E744,256 225° 60' LATITUDE DEPARTURE AZIMUTH DIP SOIL ROCK ROCK TYPE Overburden ELEVATIONS,DATUM MSL, GROUND SURFACE ROCK SURFACE BOTTOM OF HOLE WATER TABLE 1)Depths measured along hole.True depths in (). 2)All angles measured to the core axis. DEPTH (FT.) 0.0 DRILLING METHOD, LOCATION, NOTES, Run 8 32.8 1100 to (78) 36.8 80 1o~TOP OF ROCK Run 9 (6.9)Oiorite Gray-green.fine to medium grained crystalline Run 1 36.8 1 100 rock,30-40%mafics (biotite and hornblende),8.0-74 to (59) 10 up to 10%quartz.Slightly weathered,hard,to (52)40 40.5-45.0 -Core loss 0.2 feet.40.5 (8.7)fresh.Joints moderately closely spaced with 10.7 (34.6) iron oxide staining.Run 2 Run 10 8.0-10.7 -Core loss 0.7 feet.Red staining 10.7 88 40.5 1 100 in core parallel to some joints,penetrative to (60) to (90) to 0.5 inches.15.0 44.7 45.6-46.5 -Core broken by drilling. Run 3 Run 11 15.0 100 44.7 1 91to(57) 17.5 to (35)48.4-48.9 -Fracture zone,joints very closely 49.1 (15.2)Quartz Diorite Green-gray to light gray,fine to medium 19.6 spaced 0°_10°,30',and 50°-60°. grained rock.Mafics 20-30%(biotite and Run ~I Fl20hornblende),10-15%quartz,generally hard to 50 (17.3)very harp.;)resh.Gradati ona 1 contact.Run 4 (~~(43.3)Run 13 89 APPROVED,p#/W;{DATE,February 1,1982 Run 14 ! ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALAS KA PO,IER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.3 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.4 OF 24 DEPTH I DESCRIPTION'COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG,I 6~N~J~REC DEPTH DEseRI PTI ON;COLOR,TEXTURE I FOLIATION,JOINTING,FRACTURING,FAULTI NG,LENGTH I REC ROCK TYPE ROCK TYPE OF RUN (FT.l ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.(FT.)(RQDJ {FT.l ALTERATION,WATER LOSS OR GAl N,CAVI NG,LOST CORE,CEMENTING,ETC.(FT.)(~QD) Ouartz Diorite I IRun 14 Qua rtz Di or ite Run 24 51.4-100 55.5 (82)84.2 I 100 to (89) Run 15 89.3 55.5 100 89.3-94.6 -Core loss 0.3 feet. to (26)90 Run 25 59.3 (77.9)I 9489.3 60 i I IRun 16 to (70) (52.0)94.6 59.3 100 to (77) 63.2 --- Run 26 64.3-105.8 -Joints are moderately close to Run 17 63.2 97 94.6 I 97 closely spaced,at 10°to 60°,iron stained,to (33)to (79) some carbonate filled.66.5 98.598.5-98.8 -Core loss 0.3 feet. 66.5-67.3 -Core loss 0.8 feet.Core broken Run 18 RITf\2T by drillin9.Pnn Iq 98.5-83 Run 20 100 100.3 (78) 67.7 100 (86.6)101.9-102.3 -Core loss 0.4 feet.Run 28 100(75) 70 i 171.3-73.1 -Shear/fracture zone,joints very 7~Od (59)102.7-106.3 -Penetrative iron oxide stainin9 Run 29 7l(54) (60.6)on joints up to 0.5 inches.-Run 30 100 _illl closely spaced,at 30 0 _60 0 •Sli9htly to Run 21 moderately weathered,very thin clay gouge,70.4 96 Run 31 iron oxide staining.to (41)105.45 -Joint,45 0 ,clay coating 0.1 inch.103.1 I 9475.3 105.8-106.3 -Fracture zone,joints very to (61) closely spaced at 10 0 and 70 0 ,iron oxide 108.2staining,clay coating on surfaces for 0.2 Run 22 tllC feet. 75.3 100 106.3-136.8 -Joints moderately closely Run 32 to (77)spaced,generally fresh,minor iron oxide 108.2 10080.3 staining. (95.3)to (94) 111 .7 80 l I ~3 112.7-122.1 -Core loss 0.4 feet. (69.3) 80.3 100 to (77) 84.2 -~"i ~ll ~~1 ~]~;l ,1 l I :1 J , ~" eC'C_e")eCCC ')"c.el 1 CC"1 e.c ]c~cl c:~oJ ;CCl I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.5 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.6 OF 24 DEPTH (FT)ROCK TYPE DESCRIPTION;COLOR I TEXTURE,FOLIATION.JOINTING,FRACTURING.FAUL.TI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. L.ENGTH OF RUN (FT.) REC (RQD) DEPTH (FT.)ROCK TYPE DBCRIPTI ON:COLOR,TEXTURE,FOL.IATION ,JOINTING,FRACTURING,FAUL.TI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,L.OST CORE,CEMENTING.ETC. L.ENGTH OF RUN (FT.) REG (ROO) Run 4gI100(59) Run 421100 (82) Run 44 155.6 1100 to (72) 160.6 Run 45 160.6 1100 to (71) 165.7 100 (47) 94 (19) Run 48 175.2 1 91 to (10) 179.8 Run 43 150.6 1100 to (46) 155.6 Run 47 170.0 to 175.2 Run 46 165.7 to 170.0 154.2-155.1 -Fracture zone,joints very closely spaced,.at 20°to 50°,iron and carbonate staining. 155.1-168.2 -Joints very closely to closely spaced,carbonate coated,iron oxide staining. 168.2-186.8 -Shear/alteration zone,core bleached to light gray,severely altered hydro- thermally.Soft,friable with numerous re- healed fractures.Joints are close to moderately close.Contains chalky white diorite with feldspars breaking down into clay minerals,carbonate present. 176.3-177.2 -Shear zone,joints at 20°- 60°,soft and friable. 178.2-179.8 -Shear zone,joints at 20°_ 60°,0.4 feet of clay,soft and friable. 162.4-163.3 -Fracture/alteration zone,altered hydrothermally,numerous healed fractures. Joints and fractures are very closely spaced, 10°to.60°,some iron oxide staining and carbonate filling. 165.6-175.2 -Core loss 0.3 feet. Quartz Diorite 180 (155.g)1 170 (147.2) 160 (138.6) 150 (129.9) 100 (66) 100 (82) 76 (100) 100 (83) 100 (89) 100 (82) 100 (91 ) 100 (84) Run 42 145.6 to 150.6 Run 41 140.6 to 145.6 Run 40 136.2 to 140.6 Run 39 131.1 to 136.2 Run 35 116.2 to 121.1 Run 36 121.1 to 126.2 Run 37 Run 38 127.6 atl toto131.1 136.8-155.1 -Alteration along joints pene- trating slightly,average 0.06 inches up up to 0.1 feet.Joints are closely spaced,at 20°to 50°,with iron oxide staining and carbonate filling. 129.6-130.6 -Felsic dike,light gray,fine grained quartz phenocrysts,less than 5% mafics.Fresh,unfractured,tight contacts, 20°.Iron oxide stained joints,penetrative 0.5 inches. 131.0-131.1 -Felsic dike as above,20°,un- fractured,tight. 131.8-132.5 -Joints,40°,with iron oxide staining. 122.5-123.6 -Penetrative iron oxide stainin9 on joints to 0.5 inches. Quartz Di orite 130 (112.6) 140 (121.2) 120 (103.9) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.7 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.8 OF 24 210.0-215.0 -Core loss 0.3 feet. 210.0-245.0 -Inclusions of fine grained mafic rock,joints very close to widely spaced,up I Run 55 to 2.0 inches. 186.8-221.1 -Joints closely spaced,most !Run 50carbonatecoated. 184.9 1100 to (82) 190.0 Run 51 190.0 I 98 to (86) 195.1 ~- Run 52 195.1 1 100 to (82) 200.2 Run 53 200.2 1100 to (45) 205.1 DESCRIPTION:COLOR,TExT\JRE,FOLIATiON,JOINTING,FRACTURING,FAULT)NO,I ~~N~~~I REG ALTERAT!ON,WATER LOSS DR GAIN,CAVING,L.OST CORE,CEMENTING,ETC (FT.)(RQD) 221.1 -Joints moderately close to widely IRun 57spaced,most carbonate coated,occasional 220.0 1100traceofironoxidestaining.to (96) 225.2 Run 58 225.2 1100 to (85) 230.4 Run 59 230.4 1100 to (84) 235.4 Run 60 235.4 1100 to (100) 240.3 Run 61 240.3 I 96 to (90) 245.5 Run 56 215.0 I 96 to (72) 220.0 Run 55 ~mt I(~l)215.4-215.7 -Highly fractured and moderately weathered. ROCK TYPE Quartz Diorite DEFJ'rH (fT.) 240 (207.8) 220 (190.5) 230 (199.2) Run 54 205.1 I 98 to (95) 210.0 LE:NGTH I REC OF RUN (ROD)(FT) - Run 49 179.8 1 100 to (59) 184.9 DESCRIPT J o~:COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 8elow 208.0,texture fine to medium grained. ROCK TYPE Quartz Oiorite DEPTH (n.l 190 (164.5) 210 (181.9) 200 (173.2) !j ~~;1 ~•~U 11 ~_iJ 1 ;J 'I -~1 ]--1 --1 '"CC).--]I ~--l '--1 I "\ ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.9 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.10 OF 24 Run 681 100 (92) Run 63 249.7 1100 to (79) 255.0 Run 67 270.2 1100 to (56) 275.4 Run 66 265.1 I 100 to (82) 270.2 i 00 100) 100 (92) Run 69 Run 68 275.4 to 280.3 DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOIN:rING,FRACTURING,FAULTI NG,~~N~~~REG ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 1FT.)(ROD) Run 70 281.6 1100 to (100) 284.6-290.6 -Core loss 0.2 feet.1284.6 Run 71 284.6-100 286.6 100) Run 72 286.6 100 to (100) 290.5 -- Run 73 290.5 1100 to (92) 295.7 Run 74 295.7 1100 to (86) 300.7 Run 75 300.7 1100 to (100) 305.0 Run 76 305.0 I 99 to (98) 310.2 273.4-273.5 -Breccia and clay gouge,60 0 , soft and friable,carbonate filling. 273.8-315.0 -Joints moderately closely spaced with minor carbonate coating. ROCK TYPE Quartz Diorite DEPTH (FTJ 300 (259.8) 290 (251.1) 280 (242.5) 100 (86) 100 (100) Run 65 260.1 to 265.1 LENGTH I REeOFRUN(RQD)(FT.) -- Run 62 245.5 1 100 to (93) 249.7 Run 64 255.0 to 260.1 lli.QB!fI!illf:COLOR,TEXTURE,FOLlATION,JOINTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN,cAVI NG,LOST CORE,CEMENTING 1 ETC. 272.6-273.8 -Shear/alteration zone,slightly altered hydrothermally,friable,with a breccia-gouge 0.1 feet thick,closely spaced joints. 266.5-280.6 -Irregular discontinuous patches of red staining. 255.2-256.8 -Shear/alteration zone,slightly to moderately altered hydrothermally along joints,small light gray breccia and gouge zone.Numerous rehealed joints,chalky-white diorite,feldspars beginning to decompose. 256.0-256.6 -Shear,30 0 ,joints very closely spaced,clay,carbonate,and breccia filling. ROCK TYPE Quartz Diorite DEPTH (FTJ 270 (233.8) 260 (225.2) 250 (216.5) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 CLIENT ALAS KA POWER AUTHOR ITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.11 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.12 OF 24 DEPTH 1FT.)ROCK TYPE DESCRIPTiON:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTUAING,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (fT.) R!':C p'QDj DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR;TExTURE,FOLlATION ,JOI NT1NG,FRACTURING,FAULTI NG I ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. LENGTH OF RUN (H) REe (ROD) 310 (268.5) Quartz Diorite Run 76l~ Run 77 310.2 I 99 to (83) 315.4 Quartz Di orite 339.0-345.0 -Alteration zone,bleached light gray,slightly altered hydrothermally,feld- spars beginning to alter to clay.Joi·nts very close to closely spaced at 30°,generally healed and tight with carbonate filling and iron oxide staining,hard to moderately hard. 343.0 -Core loss 0.2 feet. 345.0 -Joints close to moderately closely spaced. Run 83 100 (100) Run 84 342.9 I 98 to (92) 348.8 Run 88 363.1 1100 to (75) 368.2 Run 89 368.2 1100 to (98) 373.2 Run 87 358.9 1100 to (40) 363.1 Run 86 353.8 1100 to (70) 358.9 100 (100) Run 85 348.8 to 353.8 357.9-358.6 -Fracture zone,joints very closely spaced at 10°_20°,30°,and 50°. 360.1 -Joint,50°,highly altered hydro- thermally,carbonate filling. 360.1-361.4 -Fracture/alteration zone, slightly altered hydrothermally,joints very closely spaced (scalloped).Moderately hard to soft,friable. 368.2-373.2 -Core loss 0.2 feet. 370 (320.4) 360 (311.8) 350 (303.1 ) Run 78 315.4 I 99 to (88) 320.6 Run 79 320.6 1100 to (100) 325.6 -- Run 80 325.6 1 72 to (48) 330.2 Run 81 330.2 I 20 l~g 7 (0) Run 82 332.7 I 96 to (65) 337.9 Run 83 337.9 1100 to (100) 342.9 318.8-319.7 -Shear/alteration zone,bleached light gray,slightly to moderately altered hydrothermally.Friable,feldspars altering to clay,iron oxide staining on joints and fractures. 319.2 -Shear,30 D ,0.13 inch breccia and gouge,carbonate filling. 320.6-325.6 -Core loss 0.2 feet. 321.2-321.9 -Fracture zone,00 _20.,joints very closely spaced,iron oxide staining and carbonate filling. 322.5-325.6 -Fracture/alteration zone, slightly to moderately altered hydrothermally, healed joints very close to closely spaced. Carbonate and clay filling in joints from altered feldspars,moderately hard. 323.8 -Joint,30°,slickensides,clay and carbonate ,filling,minor iron oxide staining. 324.4 -Carbonate vein,40·,0.5 inches wide, offset 0.5 inches along healed shear at 10°, tight. 328.2-332.7 -Fracture zone,joints very closely spaced,soft and friable.Core loss 3.3 feet. 320 (277.1) 330 (285.8) 340 (294.4) ]~J ~e],~c "J ']~'~J 1 "'~~l ]1 1 _.....~~]1 -'J -1 ~"1 1 1 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH·6 SHEET NO.13 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.14 OF 24 DEPTH tFl)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLlATION,JOiNTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING I LOST CORE,CEMENTING,ETC LENGTH OF RUN 1FT.) REC (ROO) DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR I TEXTURE,FOLlATION ,JOINTING,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVING.LOST CORE,CEMENTING.ETC. LENGTH OF RUN (FT) REC (ROD) Quartz Diorite 374.1-374.7 -Fracture zone,20-30°,joints very closely spaced,carbonate filling and some iron oxide stainin9. 377.2 -Joint,40°,surface severely altered hydrothermally to 0.13 inches. Run 90 373.2 I 96 to (77) 378.4 410 (355.1 ) Quartz Di orite Run 97l ~) Run 98 406.2 1100 to (98) 410.9 Run 93 388.6 1 100 to hOO) 393.3 Run 101! 420.8 I 99 to (94) 426.0 380 (329.1) 390 (337.7 380.2-382.2 -Shear/alteration zone,slightly to moderately altered hydrothermally,joints close to very closely spaced.Numerous re- healed fractures,feldspars decomposin9 to clay,soft and.friab1e. 381.5-382.2 -Shear zone,40-50°,joints very closely spaced,clay gouge,breccia. 383.3-388.3 -Core loss 0.1 feet. 382.2-477.5 -Joints closely to moderately closely spaced. Run 91 378.4 to 383.7 Run 92 383.7 to 388.6 100 (72) 100 (98) 420 (363.7) 412.0 -Inclusions of fine grained diorite, 0.2 feet in diameter,sharp contacts, irregular shape. 421.8 -Inclusion of fine grained diorite, 0.2 feet in diameter. Run gg 410.9 to 416.0 Run 10 416.0 to 420.8 100 (100) 100 (100) 400 (346.4 397.8-398.1 -Fracture zone,joints very closely spaced,at 60°to 80°,minor carbonate coating. 399.5-400.9 -Red staining,irregular and discontinuous. 402.0 -Felsic dike,granodiorite composition, 0.1 feet thi ck. Run 94 393.3 to 398.3 Run 95 398.3- 400.6 Run 96 400.6 to 403.4 Run 97 100 (86) 100 (76) 100 (95) 100 (98) 430 (372.4) Run 10 426.0 1100 to (97) 430.5 Run 103 430.5 1100 to (100) 435.6 Run 1041 100 (98) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW VORl< DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CL.IENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroe 1ectri c Project PROJECT Sus i tna Hydroe 1ectri c Proj ect SITE Watana (North Bank) HOL.E NO.BH-6 SHEET NO.15 OF 24 SITE Watana (North Bank) HOL.E NO.BH-6 SHEET NO.16 OF 24 DEPTH (fT,)RQG K TYPE DESCRJPTI ON:COLOR,TEXTURE,FOl.lATION ,JOI NTJNG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAl N,CAVI NG,LOST CORE,CEMENTI NG,ETC LENGTH OF RUN (FT) REe (ROO) DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOiNTING,FRACTURING,fAULTI NG I ALTERATION,WATER LOSS OR GAl N I CAVING,LOST CORE,CEMENTI NG \ETC. LENGTH OF RUN (FT) REO (ROD) Run 1121 95183) Run 1101 43(01- Run 108 455.~-1 88 _4~~i~ Run 109 458.21 100 to (78) 463.2 95 (83) un I Tllf<J5T1j Run 112 468.4 to 473.3 Run 116 485.3 61 to (0) 490.5 Run 117 490.51 99 to (95) 495.5-Run 118 495.51 9B to (77) 500.5 Run 115 480.3 I 94 to (65) 485.3 Run 113 473.31 100 to (92) 477 .B Run 114 477.81 92 to (72) 480.3 485.3-490.5 -Core barrel mislatched during drilling.Core loss 2.0 feet. 4Bl.9-482.6 -Fracture zone,joints very closely spaced at 40°-60°. 472.7-473.3 -Core badly broken by drilling. 477.5-477.9 -Fracture zone,joints very closely spaced,at 60°-BO°,chlorite coating. Quartz Diorite 500 (433.0) 490 (424.4) 480 (415.7) 470 (407.0)100 (98) Run 111 463.91 100 to (88) 46B.4 Run 106 445.61 100 to (90) 450.6 Run 107 450.6/96 to (79) 455.8 Run 105 440.41 100 to (94) 445.6 RUI1T04 435.6 to 440.4 454.6-455.1 -Fracture zone,joints very closely spaced,at 20°_30°and 40°_70°, carbonate coating. Ouartz Diorite 460 (398.4) 440 (381.1) 450 (389.7) .~':~.~1 ]]j ~,~.~~'j "To)1lj'J .\ rj _C)-1 -----,---1 --1 -1 -)1 -1 -····1 J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.17 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.18 OF 24 DEPTH I I OESCR,PTION,COLOR,TEXTURE,FOLlAT'ON,JO'NTlNG,FRACTUR'NG,FAULT'NG,LENGTH REC DEPTH OEseRI PTION :COLOR,TEXTURE,FOLIATION ,..101 NTING,FRACTURING,FAULTI NG,LENGTH REC ROCK TYPE OF RUN ROCK TYPE Of RUN(FT.)ALTERATION,WATER LOss OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.(FT.)(ROO](FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,"LOST COREl CEMENTING,fTC.1FT)(ROD) Quartz Diorite I IRun 119 Quartz Di orite 530.5-533.0 -Shear/alteration zone,532.0-100 moderately to severely altered hydrothermally,534.5 (52) 500.5 95 moderately hard.Feldspars altered to clay. to (91 )530.5-531.8 -F,.,to".'oi,t;y","0;e,I'"128 505.7 -Healed shear,40°,0.5 inches wide,505.6 spaced,carbonate fillin9·534.5 I 100 healed with dark green,fine grained diorite, IRun 120 531.8-532.8 -Approximately 1.0 foot of to (90) tight,hard.light gray clay gouge and breccia.539.5 505.6 100 533.5-547.5 -Core loss 1.2 feet. to 100)540 510.6 (461.1 1j 541.3-541.7 -Fracture zones,joints very Run 129 510 j I I closely spaced,at 50°and 40°,carbonate 539.5 I 100 (441.7 filling and iron oxide staining.to (73) 544.6 Run 121 510.6 99 I ~~I IRun 130to(92)544.6 I 79515.6 to (55) 547.5 516.2-516.8 -Core badly broken by drilling. j --- Run 131 517.7 -Carbonate vein,0.25 inches wide,Run 122 547.51 100 to (76)irregular and discontinuous.515.6 98 550 550.4 519.3 -Two joints very closely spaced,at to (66)(476.3) 40°,healed with carbonate.520.7 j Run 132 520 ~I(450.3 550.4 I 94 to (79) Run 12 555.4 520.7 100 to (67) 525.6 'Run 133 555.4 I 100 Run 124 I to (83) 525.6 100 559.6-561.1 -Numerous healed joints,60°,560.7 to (74)carbonate filled. 560 529.5-529.9 -Fracture zone,joints very 530.4 (485.0)560.8-561.5 -Shear,breccia healed with closely spaced at 40°,0.5 inches spacing,carbonate,chlorite,and quartz.Run 134 530 ~I carbonate filling and chlorite staining.560.71 100(459.0)Run 125 (~~to (100) 565.7 un 127 100(52) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroe 1ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.19 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.20 OF 24 DEPTH (FT)FlOCK TYPE OESCR!fI.!..Q.!'.!:COLOR,TEXTURE,FOLIATION,JOI NTI NG,FRACTURING,FAIJ l.TI NG I 6~N~J~REC ALTERATION,WATER LOSS OR IJAIN,CAVING,LOST CORE,CEMENTING,ETC.(FT)(RQDJ DEPTH (FT)ROC\(TYPE DESCRIPTION:COLOR,TEXTURE,~OLlATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC L~N!3TH REe O~F~~N (RQD) 99 (82) 570 (493.6) 580 (502.3) 590 (511.0) Quartz Diorite 1564.6-576.7 -Shear/alteration zone,light gray,slightly to moderately altered hydro- thermally.Joints close to very closely spaced,generally 20°_80°,numerous healed fractures.Feldspars decomposing to clay, carbonate filling and iron oxide staining. Soft,friable in places.Core loss O.B feet. 569.0 -Shear,60°,very thin clay gouge. 571.9-572.7 -Breccia and clay 90uge, white to light gray,20 0 and 50 0 ,soft, friable. 579.5-580.7 -Fracture/alteration zone, sli9htly altered hydrothermally,joints very closely spaced,numerous healed fractures. 581.1-604.3 -Joints closely spaced,some carbonate filling and iron oxide stainin9. 583.4-583.7 -Core broken by drilling. 590.8-592.8 -Core barrel mislatched during drilling.Core loss 0.6 feet. ~n 1341100(lOC Run 135 565.71 90 to (7) 570.7 Run 136 570.7 I 94 to (83) 575.9 Run 137 575.91 98 to (61) 580.7 Run 138 580.71 100 to (64) 585.8 Run 139 585.81 100 to (51) 590.8 Run 140 590.8t 70 592.8 ~ Run 141 592.8 to 597.8 600 (519.6) 610 (528.3) 620 (536.9) Quartz Diorite 602.1-602.6 -Core broken by drilling. 607.7-607.9 -Core broken by drilling. 611.3-612.4 -Felsic dike.light gray,fine grained,fresh,6.0 inches thick.Lower and upper contacts at 10°,ti9ht. 626.1-627.2 -Felsic dike as above,light gray,fine grained,20-30%quartz,5-10% mafics,interfingering or containing clasts of the quartz diorite.Unfractured,contacts tight and melted,upper at 70°,lower at 40°. Run 141199(82) IRun 142 597.8 [100 to (42) 602.6 Run 143 602.61 100 to (61) 608.3 Run 144 608.31 100 to (89) 611 .8 Run 145 611.81 78 to (64) 615.4 Run 146 615.41 100 to (96) 620.3 Run 147 620.3\100 to (94) 625.2 Run 148 625.2\92 to (79) 630.2 '!~~1l ~~~~1 ~..S 11 1 ~,i.·1JJdJ3j '--J '---~J '-,"]""'-"-J --1 .----']-'1 --J '--J -J 1 '] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHOR ITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroel ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.21 OF 24 SITE Watana (North Bank) HOLE NO.BH-6 SHEET NO.22 OF 24 DEPTI1 {FT.)RDel<TYPE DESCRiPTION:COLOR I TEXTURE,FOUATION,JOINTI NG,FRACTURING,FAuLTI NG, ALTERATION,WATER L.OSS OR GAl N I CAVING,L.OST CORE,CEMENTING.ETC. LENGTH OF RUN (F1~) REC (RaO) DEPTH (IT)ROCK TYPE OESCRIPTI ON;COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING I LOST CORE,CEMENTING.ETC. LENGTH OF RUN (FT.) REC (RQD) Run 153 648.7-649.7 -High concentration of biotite.1645.61 99 I R 680649.7 to (88)(588.9)(562.7)650.5 650 Granodiorite Light gray-white,generally fine to medium (562.9)grained crystalline rock,60-80%feldspars, 10-20%mafics (biotite),10-20%quartz.Run 154Generallyhardandfresh,some feldspars sta i ned brown.Upper contact is gradational 650.5 I 98 over 0.1 feet,feldspars slightly altered,to (88) ti ght •655.8 656.0-670.0 -Numerous healed joints,calcite filling.IRun 155 655.81 96 I ~690to(50)(597.6)660.6 I I I 660 (571.6)1 I IRIinT5fi Run 150 631.81 100 to (80) 636.7 100 (74) Run 156 660.6 to 665.7 Run 157 665.71 97 to (90) 670.8 ~- Run 158 670.81 100 674.4-674.7 -Core broken by drilling.1 to (58) 676.0 Run 159 676.0 I 97 to (93) 680.6 ---- Run 160 680.61 98 to (90) 685.4 -- Run 161 685.4-76 687.9 (72) Run 162 687.9 100 to (91) 692.5 un Granodiorite 670 (580.2)100 (100) Run 148 IRun 151 636.7 to 640.5 IRun 152 640.5 1 98 to (85) 645.6 92 IRun 1491~r (72) Core loss 0.4 feet.Quartz Diorite 640 (554.3) 630 (545.6) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroel ectric Project SITE 720 (623.5) Wa tana (North Bank) 722.0-727.1 -Core loss 0.1 feet. HOLE NO BH-6 SHEET NO 23 OF 24 Run 168 717.1 11 OU to (92) 722.2 Run 169 722.21 99 to (69) 727.3 SITE 750 (649.5) Watana (North Bank) HOLE NO.BH-6 SHEET NO.24 OF 24 l 4 1 ]1I ~]u -p J J 'J ~]1 -j ]~]J J 1 ~1 1 1 -]] Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Cli ent ~HSK~,POWER AUTHOR ITY Project Susitna Hydroelectric Project Site Watana (North Bank) DEPTH (FT.) 20 I I I I I I I I 40 60 80 100 120 140 160 180 200 220 240 260 280- 300 320 340 Job No.P5700.05 Hole No._~B~H_-6~_ Sheet No .._1_of _3_ REMARKS TOP OF ROCK 8.0' Fracture zone. Shear/fracture zone Fracture. Alteration zone. Shear/alteration zone. Shear. Shear. Fracture zone. Alteration zone.• Client __ALASKA POWER AUTHORITY Project Susitna Hydroelectric Proiect Site Watana (North Bank) DEPTH 1FT.) 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 I I I I I I I-H 700 Job No.P5700.05 Hole No.-----.!lli.=.6. Sheet No.---.2-of---3.- REMARKS Shear. Shear,healed. Shear/alteration zone. Shear/alteration zone. Dike,felsic. Dike,felsic. • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client----!iLASKA PO'/IEIl,AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.BH-6 Site Watana (North Bank)Sheet No._3_of __3_ PERMEABILITY CORE RECOVERY ROO NUMBER OF DEPTH ElEV.(K)em/nco %%JOI NTS PER ROCK TYPE REMARKS(FT.)(fT.)10FT. 10-6 10"4 10-2 20 40 60 eo .20 40 60 80 5 10 15 20 720 --II- 740 968 f-END OF BORING I 740.4' _0 ---_0 I.-'----- J - -_._-0- -f--- ----- ----- _"0-1-'_---e-- -f----- ----- -- --_.--._- .f---I • ., J -----1 --"'"1 ~1 "--1 ---])"]--]-1 1 -j ]-1 "I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT,ALASKA POWER AUTHORITY JOB NO.:P5700.05 PROJECT,Susitna Hydroelectric Project HOLE NO.,BH-8 SITE:Watana (South Bank)SHEET NO.1 OF 24 CONTRACTpR,The Dri 11 i ng Company DRILLING DATES'.July 29 TO August 9.1980 LOGGED BY,.K.J.White,M.P.Bruen DATE:July 1980 LATITUDE N3,225,586 ELEVATIONS,DATUM MSL,A.S.P.C.,Zone 4 DEPARTURE E744,482 GROUND SURFACE 1979.7 AZIMUTH 060 0 ROCK SURFACE 1972.8 DIP 60 0 BOTTOM OF HOLE 1328.1 WATER TABLE 1963.7 Depths measured along hole.True depths in (). All angles measured to the core axis. Run 2 18.0 90 18.3-34.1 -Slightly to moderately weathered.to (20) Joints very close to close spaced.Core loss 23.8 -1 1.2 feet. HOLE NO.BH-8 SHEET NO.2 OF 24 REC {RQD} 92 (58) P5700.05 LENGTH OF RUN (FT.) Run 3 23.8 to 28.8 JOB NO. OESCRI?TI ON :COLOR,TEXTURE,FOL.IATION ,JOINTING,FRACTURING,FAUL.TI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. Watana (South Bank) ROCK TYPE Andesi te Porphyry DEPTH 1FT.) SITE PROJECT Susitna Hydroelectri c Project CLIENT ALASKA POWER AUTHORITY CASING DIAMETER,NW (3.0")I.D. CORE DIAMETER:NO (1.75")O.D. Casin9 Advancer Diamond Core -Triple Tube SOIL ROCK LOCATION, DRILLING METHOD, NOTES,1) 2) 98 (77) 100 (0) 73 (26) 79 (56) 100 (35) Run 6 Run 5 Run 8 45.6 to 49.6 Run 7 43.9-45.6 Run 4 38.8 to 43.9 33.8 to 38.8 28.8 to 33.833.8-38.8 -Core loss 1.1 feet. 34.1-49.6 Fresh to slightly weathered.Joints very close to close spaced with nonpenetrative iron oxide staining. 44.3-49.6 -Fracture zone,joints very close spaced. 46.0-47.1 -Subrounded to subangular inclusions of argillite.quartz,diorite.and volcanics up to 2 inches,andesite matrix. 47.1-49.6 -Moderately to severely weathered. Silty to sandy clay with 20-30%subangular to subrounded.coarse sand.Core loss 1.1 feet. Drilling water return 50%. 40 (34.6) 30 (26.0) 49.6 (43.0)n--~"---150DioritetoLightgraytogreenishgray,fine to medium Run 9 72 (43.3)Quartz Diorite grained.nonfoliated crystalline rock.50-80%49.6-(0) feldspar,20-40%mafics (biotite and horn-52.5 blende),0-15%quartz and trace carbonate. 64 (0) % REC (RQO) 90 (20) RUN L.ENGTH No Core Run 1 13.8 to 18.0 1illn2 18.0 to 23.8 DATE,February 1,1982 DESCRIPTION:COLOR .TEXTURE,FOL.IATION,,JOINTING,FRACTURING.FAULTING, ~N,WATER LOSS OR GAIN I CAVING I LOST CORE,CEMENTING,ETC. I / ROCK TYPE &Iiv?!{CfIv Overburden0.0 OEPTH (FT) APPROVED, 10 (8.7) 20 (17.3) (~:~)~desite Light gray to greenish gray,aphanitic ground-I I I Porphyry mass with white,feldspar phenocrysts to 0.1 inch and 5-10%angular inclusions of argillite to 0.5 inch.Slightly weathered and hard. Flow structures visible. Joints very close to close spaced with planar to irregular,rough surfaces.Penetrative iron oxide staining up to 0.5 inch,minor carbonate filling. 8.0-13.8 -No core taken. 13.8-18.3 -Moderately weathered.Joints very close spaced with traces of sand and silt. Core loss 1.5 feet. ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHOR ITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.3 OF 24 SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.4 OF 24 DEPTH (FT.) 60 (52.0) 70 (60.6) 80 (69.3) ROCK TYPE Di orite to Quartz Diorite DESCRIPTION:COLOR,TEXTURE,FOLIATiON ,JOINTING,FRACTURING,FAULTI NG , ALTERATION,WATER Loss OR GAIN,CAYI NG,LOST CORE,CEMENTI NG I ETC. Fresh and very hard to hard. Joints close spaced.planar to rough. Carbonate coating on most surfaces. 49.6-53.4 -Fracture/alteration zone,hydro- thermally altered.joints very closely spaced. 50.1-52.9 -Two alteration zones,severely hydrothermally altered.1 inch wide,30·, soft and friable. 53.4-61.4 -Joints closely spaced,iron oxide stained. 60.3-61.4 -Healed shear,diorite breccia in dark gray,fine grained diorite matrix.Hard and tight.Carbonate stringers. 61.4 -Contact resheared,30·,0.1 inch clay gouge. 61.4-64.5 -Alteration zone,moderately hydro- thermally altered.Joints very close to close spaced. 62.2,62.9,64.4 -Severely hydrothermally altered zones,1 .0-2.0inches wide,at 50-70·. soft and friable. 64.5-75.0 -Joints very close to close, surfaces fresh. 65.0-66.0 -Three healed shears up to 1 inch wide,at 50·.Healed with dark green,fine grained diorite.Hard and tight. 75.0-78.8 -Fracture zone,joints very close to close spaced,open at 10-30·,90·,and D·. Some treated with carbonate,minor iron oxide staining and chlorite. 78.8-91.6 -Joints close spaced.Iron oxide staining,some carbonate filling.Slickensides on some surfaces. 82.0-85.4 -Fracture zone,joints very close spaced at 80-90·,50-60°,and 20-30·.Minor iron oxide staining,carbonate and chlorite. 83.5 -Slickensides on carbonate staining. LENGTH OF RUN (FT.) Run 10 52.5 to 56.5 Run 11 56.5 to 59.5 Run 12 59.5 to 63.6 Run 13 63.6 to 68.0 Run 14 68.0 to 73.0 Run 15 73.0 to 77 .7 Run 16 77.7 to 80.7 Run 17 80.7 to 84.0 Run 18 REC (RQO) 91 (11 ) 100 (Ii?) 85 (67) 100 (69) 100 (87) 100 (48) 100 (25) 97 (55) DEPTH IFTJ 90 (77.9) 100 (86.6) 110 (95.3) ROCK TYPE Diorite to Quartz Diorite DESCRIPTION;COLOR I TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG , ALTERATION,WATER LOSS OR GAIN,CAlliNG,LOST CORE,CEMENTING,ETc. 88.4-91.6 -Fracture zone,joints very closely spaced at 0-30·.Iron oxide staining,some carbonate filling. 91.6-96.6 -Core loss 0.6 feet. 100.0-141.0 -Joints closely spaced,planar, rough.Iron oxide staining and carbonate coating. 105.2-111.4 -Healed shears,1-2 feet spacing up to 0.1 feet wide.Healed with dark 9reen, fine grained diorite.Tight,hard. 116.1-121.1 -Core loss 0.3 feet. LENGTH OF RUN (FT.) Run 18 84.0 to 89.3 ~n19 89.3- 91.6 Run 20 91.6 to 96.6 Run 21 96.6 to .101.0 Run 22 101.0 to 106.2 Run 23 106.2 to 111.0 Run 24 111.0 to 116.1 Run 2~ REC (RQu) 98 (63) 100 (0) 88 (57) 100 (91) 100 (83) 100 (94) 100 (92) 1 ~:1 ~~~]11 ~l "1 '0 "-i i 3 J ~~J ._J -"-.]"'--1 ).·'-1 ..-j ]~.-1 ..-J 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Sus itna Hydroel ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.5 Of 24 SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.6 Of 24 DEPTH I DESCRIPTION:COLOR I TfXTURE,FOLIATION,JOINTING,FRACTURING,FAULT!NG,LENGTH REC DEPTH DESCRIPTION:COLOR,TEXTURE,FOliATION,JOINTI NG ,FRACTURING,FAULT!NG,1 6~N~J~I REC ROCK TyPE OF RUN ROCK TYPE{FT}ALTERATION,WATER LOSS OR GAIN 1 CAVING,LoST CORE,CEMENTING.ETC.(F"r)(RQD)(FTJ ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC (FT.l (RQO) Diorite to Di orite to 148.9-149.3 -Diorite dike,dark green,fine Quartz Di orite Run 25 150 Quartz Diorite grained.Tight irregular contacts at 30·,I Run 32 116.1 95 (129.9)hard.148.0 1100 to (80)to (96) 120 ~,/121.1 152.6-167.5 -Core loss 0.7 feet.152.6 (103.9) Run 26 Run 33 121.1 100 152.6 1100 to (76)to (89) 126.1 157.7 Run 34 Run 27 160 157.7 I 96 126.1 100 (138.6)to (85) to (98)162.7 130 ~I I~(112.6) Run 35 Run 28 162.7 I 90 131.1 100 to (79) to (88)167.5 135.6 Run 36 Run 29 170 167.51 99 135.6 100 (147.2 171.5-173.0 -Shear/alteration zone,hydro-to (86) to (82)thermally altered,bleached white,medium hard 171.9 140.8-142.9 -Core loss 0.5 feet. 1 140 .8 140 1 1141.0-190.0 -Joints closely spaced,planar, to soft and friable,joints very close,some (121.2 I Run 30 tight and healed with chlorite.Clay g~uge Run 37 rough.Carbonate or chlorite filling.less than 3 inches.Angular fragments 0.5-1.0140.8-79 inches.Resheared healed shea~core loss 0.7 171.9 I 85143.9 (26) 1--.feet.to (39) 176.5-182.7 -.Red staining intergranular.176.5 145.0-147.1 -Shear/fracture zone,joints very Run 31 Irregular,discontinuous. close,40-90·.Chlorite filling.142.9 100.)I Run 381 146.0-146.3 -Slickensides on chlorite surface.to (70)176.51 90 Joints tight.Fresh and hard.148.0 180.7-181.0 -Possible fracture zone,core to (80)r laC broken into fragments less than 1 inch,some 181.0 Run 32 (155.9 fragments of healed breccia core loss 0.5 feet ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.7 OF 24 SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.B OF 24 DEPTH (fT)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTING, ~ERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FTJ REC (RQD) DEPTH (FTJ ROCK TYPE OESCRIPT\O~:COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH Of AUN (FTl REC (ROO! Run 40 '";-1 r'8189.2 (73) Run 41 189.2 I 100 to (98) 194.2 190 (164.5) Oi orite to Quartz Oiorite 189.2-189.4 -Possible fracture zone,sli9htly to moderately hydrothermally altered,fragments less than 1 inch,some healed breccia.Core loss 0.4 feet. 190.0-230.0 -Joints moderately close spaced, plane,rough,carbonate coated. Run 39 181.0 to 185.9 100 (97) 220 (190.5) Di orite to Qua rtz Di orite 221.2-222.2 -Fracture/alteration zone,hydro- thermally altered,bleached white,joints very close at 30-40°.Iron oxide staining, slightly altered,hard. 224.1-228.1 -Red staining,irregular,dis- continuous. 225.4-230.6 -Core loss 0.2 feet. ,Run 46 21~'9-1 }OO~~68) Run 47 215.1 1100 to (88) 219.3 RiJrlI+!j 219.3-100 221.2 100 Run 49 221.21 100 to (83) 225.4 200 (173.2 210 (181.9 199.0-201.8 -Red staining,discontinuous. 200.5 -Healed shear,40°,1 inch wide, healed with dark green diorite.Tight,hard, competent. 206.8-207.9 -Fracture/alteration zone, hydrothermally altered,joints very close at 30°,healed with carbonate,iron oxide staining,patches of rock bleached white, tight,hard. 210.9 -Healed shear.0.5 inch wide,carbonate filling at contact,tight,hard,healed with dark green diorite. 211.0-215.1 -Core loss 0.6 feet. Run 42 194.2 I 100 to (98) 199.2 I ~~~43~W~ Run 44 201.0/100 to (100) 206.4 ~. Run 45 206.41 87 to (76) 211 .0 Run 46 230 (199.2 240 (207.8 230.0-290.0 -Joints moderately close,plane, rough,carbonate coated. 230.6-231.8 -Joint,tight,red staining penetrating 0.5 inches on each side. 238.7,239.2,246.2 -Healed shears,20-70°, less than 1 inch wide,healed with dark green, fine grained diorite,tight,hard. Run 50 225.41 96 to (71) 230.6 ~ Run 51 230.61 96 to (94) 235.6 Run 52 235.61 98 to (89) 240.9 Run 53 240.91 100 to (91) 245.6 J !I 1 9 ~1)1 1 1 '1Ii ---1 ,'·e ]~l "]--'1 ---']]-_e-1 '1 1 _C)1 ~'-'-1 -] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroel ectri c Proj ect SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.9 OF 24 PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.10 OF 24 DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLlATION ,.101 NTING,FRACTURING,FAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTI NG.ETC. LENGTH I REC OF RUN (ROD)(FT) DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION I .101 NTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING.L.OST CORE,CEMENTING.ETC LENGTH OF RUN (FT/ REC (RQD) Run 64 291.0 1100 to (75) 296.1 Run 65 296.1 1100 to (89) 300.8 Run 66 3008:1 ;" 3n3.~(95) Run 67 303.7 100 to (76) 308.8 306.5-308.5 -Core broken during drilling, fresh angular pieces. 300.8-302.5 -Healed shear zone,50-70°,very close shears healed with dark green quartz diorite,tight,hard.competent. 294.6-295.9 -Core badly broken during drilling. Quartz Diorite IJoints moderately close to close,planar,I Run 60toGranodioritesmoothtorough,mostly carbonate coated.275.3 1100 to (100) 280 ~1280.7-781.0 -Dik,!po"j b1,',,'oj'oo of ~O'3(242.5)granodiorite,fine grained groundmass of orthoclase feldspar and quartz,medium grained Run 61 plagioclase feldspar phenocrysts,tight 280.3 I 98 contacts,hard.to (98) 284.4 Run 62 284.4 I 94 287.8-291.0 -Core barrel mislatch during ~o (85) drilling.Core loss 1.0 feet.287.8 Run 63 290 ~1290.0-330.0 ~Joints moderatel.'(close,planar,I ~~i'~-I (~~) (251.1 rough,few wlth carbonate coatlng.. 300 (259.8 100 (77) Run 58 270.1 to 275.3 265.1 1100 to (62) 270.1 Run 54 245.6 1 98 to (81) 251.0 Run 55 251.0 1100 to (57) 255.2-- Run 56 255.21 100 to (76) 260.1 Run 57 260.1 I 98 to (70) 265.1 261.6-262.2 -Healed shear,10-20°,healed with dark green diorite,tight. 246.8-247.2 -Alteration zone,slightly to moderately altered hydrothermally,feldspars altering to clay,mafics completely altered, bleached white.Joints at 50°with iron oxide and carbonate,hard to moderately hard. 250.0-251.8 -Possible shear/alteration zone, bleached light gray,slightly to moderately hydrothermally altered,hard to moderately hard.Joints very close at 50°,most tight but some opened by drilling,carbonate filling and iron oxide staining.Some clay on joints from altered feldspars. 251.8-324.5 -Joints close to moderately close except where noted. 254.8-258.8 -Red staining,irregular, discontinuous. Oiorite to Quartz Diorite 270 (233.8 27l.5L-(235.l~Quartz Oiorite Light gray,medium grained,non-foliated,1Run 59 to Gradodiorit crystalline with 15-30%mafics (biotite and hornblende),10-15%quartz,up to 10%pink feldspar.Gradations to granodiorite. Contains inclusions of fine grained diorite, trace of pyrite and carbonate.Generally very i----I I hard to hard,fresh and competent. 260 (225.2)1 250 (216.5) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 'PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO,BH-8 SHEET NO,11 OF 24 SITE Watana (South Bank) HOLE NO,BH-8 SHEET NO.12 OF 24 DEPTH (FT.l ROCK nPE OESC;RIPTI ON;COLOR,TEXTURE,FOLIATiON,JOI NTI NG,FRACTURING,FAuLTI NG,~~N~~~I REC ALTERATION,WATER LOss OR GAIN,CAVING,LOSTCOAE,CEMENTING,ETC (FT)(RQO) DEPTH (FT.)ROCK T'!'PE O!::SCRIPTION :COLOR I TEXTURE.roLiATION ,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATI':R LOSS OR GAIN,CAVING,LOST CORE,CEMENTI NG,ETC. Ll::NGTH OF RUN (FT) REC (RQD) 310 ~Quartz Diorite (268.5)'to Granodiorite Run 68 308.8 \100 to (93) 313.2 Diorite/ Di orite Porphyry phenocrysts,fresh,hard. Joints coated with chlorite and carbonate. Run 75 340.1-1 ,~~,~3~~ Run 76 Run 70 318.31 94 to (84) 321.5 Run 77 348.4 1100 to (68) 351.8 346.3-351.9 -Joints close to moderately close,3~~.2 carbonate coating and filling.348.4 Rock description,as above. 320 (277.1) 324.6-333.1 -Felsic,possible aplite dikes, light pinkish gray,3 and 2 inches wide at 30°and 20°,respectively.Unfractured,hard. Run 69 313.2 to 318.2 Run 71 321.5 to 326.9 100 (98) 100 (94) 347.2 (300.7) 350 (303.1) Quartz Diorite 351.9-437.5 -Joints close to very close, planar,smooth to rough,carbonate coated, zones of iron oxide staining. Run 78 351.8 to 356.8 Run 79 100 (100) 100 (100) 100 (62) 100 (90) -gs- (69) Rlin!l33~~.5 I l(~q) 375.8 Run 80 360.9 to 364.2 356.8 to 360.9 -m.fi1lIT 360.9-361.1 -Diorite porphyry inclusion. 366.3(317.2~Diorit~Dar,k.gre~n sh g~ay.fine grained.crystalline Run 82 Porph;;y I matrlx Wlt medlum to coarse gralned p,lagioclas phenocrysts,40-50%mafics,fresh,365.51 100 hard,to (82) 369.5 -Felsic dike,light gray,1.5 inches 370.5 wide,30°,fractured alon9 trend,tight contacts. 370 (320.4 360 (311.8) 100 (90) 97 (97) 100 (96) 335.8 to 340.1 Run 73 Run 74 Run 72 326.9 to 330.8 330.8 to 335.8 330.0-346.3 -Joints close to very close, planar,smooth to rough.Carbonate coated with zones of iron oxide staining. Diorite/D~k greenish gray,fine grained crystalline Porphyry I rock with medium grained plagioclase 340 (294.4 339.3 (293.8 330 (285.8 J 'Ii "\]~.~~~}l 1 ~ J ;i j " _Co]---1 ]--]~--)-])_-e -1 c-_.)~'-l ---l _eel ] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO t NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.13 OF 24 SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.14 OF 24 377.0 I rl Run 84(326.5)Quartz Diorite Rock description,as above. 378.3 -Felsic dike,possibly aplite,light 375.8 gray,unfractured,0.5 inches wide,40 0 ,tight.to380.7 38D (329.1) Run 9D 4D3.5 I 91 to (26) 4D9.0 Run 91 4D9.D I 93 to (49) 413.1 DEPTH (FT.l ~OCK TYPE Oi orite Porphyry DESCRIPTION:COLOR I TEXTURE,FOLlATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAY lNG,LOST CORE,CEMENTING.ETC. LENGTH I RECOFRUN (FT.)(ROD) J<UrlllT 370.5 1 100 to (91 ) 375.8 10D (86) I DEPTH (FT.) 410 (355.1) ROCK TYPE Quartz Di orite OESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTlNG,FRACTURING,FAULTING, ALTERATION,WATER LOSS DR GAIN,CAVI NO,LOST CORE,CEMENTING,ETC 405.3-41D.9 -Fracture/alteration zone, yellowish gray,slightly hydrothermally altered,generally moderately hard but occasionally soft.Carbonate and iron oxide staining. 407.1 -Moderately to severely altered, possible shear,2.0 inches wide.Broken rock fragments less than D.5 inch. LENGTH OF RUN (FT.) REC (ROD) Run 85 380.7 I 89 to (56) 384.3 385.1-387.0 -Shear/alteration zone slightly to moderately altered hydrothermally,soft and friable.Iron oxide staining and carbonate filling on joints.Silty sand gouge.Core loss 0.4 feet. 385.1-400.5 -Iron oxide staining on most joints. 39D (337.7) 40D (346.4)1 403.5-413.1 -Core loss D.8 feet. Run 86 384.3 I 98 to (36) 389.3 Run 87 389.3 1 98 to (67) 393.7 --- Run 88 393.71 100 to (lDD) 398.0 Run 89 398.0 I 100 to (93) 403.5 Run 90 42D (363.7 430 (372 .4 418.3-418.5 -Healed shear,quartz diorite breccia in fine grained quartz diorite groundmass,tight. 420.0-429.0 -Iron oxide staining on most joints. 433.7-437.5 -Shear/fracture zone,joints very close,20 0 _50 0 ,some healed with carbonate. 433.7-434.81 436.1-437.5)Soft and friable rock, slickensides,chlorite,clay gouge to 2.0 inches.Core loss 1.1 feet. Run 92 413.1 110D to (73) 418.3 Run 93 418.3 10D to (79) 422.5 Run 94 422.5 100 to (100) 427.6 Run 95 427.61 100 to (57) 432.2 -- Run 96 432.2-69 434.8 (38) Run 97 89434.8- 437.5 (24) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORk DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORk DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.15 OF 24 SITE Watana (South 8ank) HOLE NO.8H-8 SHEET NO.16 OF 24 DEPTH (FT.) 440 (381.1 ) 450 (389.7 ROCK TYPE Quartz Diorite oEseR I PTlO~:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FA\.!LTI NG, ALTERATION,WATER LOSS OR GAIN,CAY lNG,\..OST CORE,CEMENTI NG,ETC 437.5-453.3 -Joints very close to close spaced,healed with carbonate,iron oxide stained. 443.1-446.2 -Shear/alteration zone,rock bleached white,40-90 0 ,moderately weathered. Joints and fractures close,rough,planar. 0.8 feet clay gouge. 448.4-453.4.-Core loss 0.6 feet. 453.3-610.0 -Joints moderately close to close,planar,smooth to rough,some carbonate coated. LENGTH OF RUN (FT) I I Run 98 437.5 to 442.2 Run 99 442.2 to 447.2 Fun 100 447.2 to 452.2 Run 101 452.2 to 457.4 Run 102 REC (ROO) 98 (66) 94 (54) 88 (88) 100 (100) DEPTH (FT) 470 (407.0) 480 (415.7) 490 (424.4), RO~K TYPE Quartz Di orite DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG I ALTERATION,WATER LOSS OR GAIN,CAVING,L.OST CORE,CEMENTING,ETC 477.8-478.0 -Alteration zone,rock bleached white,moderately hydrothermally altered, soft and friable along joints at 50 0 • LENGTH OF RUN (FT.) un 105 468.4 499.4 Run 106 471.4 to 476.6 Run 107 476.6 to 481.8 un 108 1181.5-483.0 Run 109 483.0 to 486.8 Run 110 486.8 to 491.6 REG (RQD) 100 (100) 100 (100) 100 (75) d881 92 (82) 100 (100) 460 (398.4 457.41 100 to (100) 462.2 Run 111 Run 103 462.2 to 466.6 Run 1041 466.6- 468.4 100 (100) 100 (89)500 (433.0 494.2-496.8 -Alteration zone,rock bleached white,hydrothermally altered,soft and friable.Core loss 0.5 feet.Feldspars weatherin9 to clay,slightly to moderately altered. 499.4-502.7 -Felsic dike,light gray,fine to medium grained,less than 10%mafics,hard. 491.6 to 496.6 Run 112 496.6 to 501.7 90 (48) 100 (96) '\4 ]~q J ))'j ,3 j ~,)~]j )"--1 1 C~C]eCl ~__C)1 "'~J -1 -l c_]~C_-J CCC']] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFf'ALO t NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Sus itna Hydrael ectri c Project 100 (100) Run 120 537.91 98 to (86) 542.9 Run 121 542.91 100 to (100) 548.1 L.ENGTH I RECOFRUN (Ft)(ROD) - Run 119 532.6 I 96 to (64) 537.9 Run 12 562.81 96 567.8 (0) Run 125 558.0 I 98 to (0) 562.8 Run 122 548.1 to 552.8 RiJilTlJ I 00 ~~U-(0) Run 124 554.2 100 to (0) 558.0 I I ..J HOLE NO.BH-9 SHEET NO.18 OF 24 DESCRIPT~;COLOR,TEXTURE,FOL.IATION,JOINTING,FRACTURING,FAULTING, AL.TERATION.WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC 553.0-569.9 -Fractured/alteration zone, bleached white-gray,slightly to moderately hydrothermally altered,joints very close to close at 30-60 0 ,healed with carbonate,iron oxide stained.Moderately hard to soft, friable in places.Feldspars altering to clay.Core loss 0.2 feet. 535.0-536.3 -Occasional friable zones with clay up to 0.1 feet.Core loss 0.5 feet. ROCK TYPE Watana (South Bank) Quartz Diorite SITE DEPTH tFrJ 550 (476.3) 540 (467.7) 560 (485.0) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-8 SITE Watana (South Bank)SHEET NO.170F 24 DEPTH DESCRIPTION:COLOR,TEXTURE,FOL.IATIDN,JOINTING,FRACTURING,FAUL.TI NG,L.ENGTH REe ROCK TYPE OF RUN{FLl AL.TERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FrJ (ROD) Quartz Diorite Run 113 501.7 96 to (87) 507.0 508.4-520.7 -Alteration zone,bleached white-Run 114 gray,slightly to moderately hydrothermally 507.0 88altered,numerous healed joints.Feldspars to (28) 510 altering to clay,moderately hard but friable 512.0(441.7)in places,joints close at 30-70 0 • Run 115 512.0 94 to (0) 517 .4 Run 116 517.4 100520to(34) (450.3)522.4 Run 117 522.4 100 to (98) 527.5 Run 118 527.5 96 530 to (92) (459.0)531.5-540.9 -Alteration zone,bleached white-532.6 gray,slightly to moderately hydrothermally altered,moderately hard to soft.Feldspars alterina to clav. ACRES AMERICAN INCORPORATEO -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroel ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.19 OF 24 SITE Watana (South Bank) HOLE NO.BH-8 SHEET NO.20 OF 24 DEPTH (FT.)ROCK TYPE OESCRIPTJ ON :COLOR,rlexTURE,FOLIATION ,JOI NT1NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC LENGTH OF RUN (FT.l REG (ROD) DEPTH (FT,)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JO!NTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETc. LENGTH OF RUN (FT) FlEe (RQD) 100 (74) Run 136 610.6-100 614.0 (47) Run 137 614.0 96 to (50) 619.2 Run 134 602.6-97 605.6 (77) Run 135 605.6 100 to (92) 610.6610.8-635.2 -Joints close to very close, many healed with carbonate. 593.3 -Shear,30 0 ,2 inches wide,brecc~nd ~l goug~,mode~ate1y ~O!t,SUlphide minera1ization Run 133 and lron oXlde stalnlng. 597.6 to 602.6 Quartz Diorite 610 (528.3) 600 (519.6) 96 (0) 94 (39) 92 (87) 100 (98) Run 130 5B2.1 1100 to (100) 587.2 Run 129 577.0 to 582.1 l(lJi1T2o 562.8 to 567.8 ,Run 127 567.8 to 573.2 581.6-582.5 -Alteration zone,bleached white, slightly altered hydrothermally,hard. 573.0 -Texture of quartz diorite changes. Quartz and white feldspar are fine grained and intergrown,green feldspar (20-30%)is medium grained.Run 128 573.2 to 577.6-586.6 -Joints close to moderately close,~~~ carbonate coating and iron staining. 569.0-578.8 -Healed shears,closely spaced, less than 0.1 feet wide,healed with dark 9reen,aphanitic quartz diorite,ti9ht.Core loss 0.6 feet. Quartz Diorite 570 (493.6) 580 (502.3) IRun 140 590 (511.0) 589.0-592.5 -Shear/alteration zone,bleached white-gray,sli9ht1y altered hydrothermally, healed and resheared.Numerous,very close shears healed with possible quartz/andesite, randomly oriented from 0-90 0 ,hard. 589.0-589.32 592.1-592.55 Zones of reshearing, breccia,and gouge,moderately soft and friable. Run 131 587.21 100 to (71) 592.3 Run 132 592.31 98 to (81) 597.6 620 (536.9) 626.2-627.7 -Core broken by drilling,rock fragments 1-2 inches,possible fracture zone. Run 13 619.2 100 to (56) 622.6 Run 13 622.6 100 to (54) 627.8 ~3 !j ~~1 ~1 ~Jl --~ "'-1 ""]"")-""'})') """'. "l ,.,"]0)._]--"]1 630 J Quartz Diorite 1628.2-629.8 -Core badly broken,rock fragment (545.6)I 1.0-2.0 inches.~~~~~ ACRES AMERICAN INCORPORATEO -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT fun 141 630.4 1100 to (69) 635.6 635.2-700.0 -Joints moderately close,planar, smooth,most carbonate coated.I I I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-8 SITE Watana (South Bank)SHEET NO.22 OF 24 DEPTH DESeRI PTION :COLOR,TEXTURE,FOLIATION ,..lOI NTI NG,FRACTURING,FAULTI NG,LENGTH REC ROCK TYPE OF RUN (FT,}ALTERATION,WATER LOSS OR GAIN,CAVING,"LOST CORE,CEMENTING,ETC.1FT.)(RaD) Qua rtz Di orite Run 147 660.7 100 to (100) 665.8 Run 148 665.8 100 to (96) 671.1 670 (580.2) 671.1-676.4 -Core loss 0.3 feet. Run 149 671.1 94 to (85) 676.4 Run 15C 676.4 100 to (100) 680 681.6 (588.9) 682,3-690.8 -Red stainin~,irregular and discontinuous,intergranu ar.Run 151 681.6 100 to (98) 686.9 Run 15 686.9 100 690 to (92) (597.6)692.2 692.2-695.0 -Core barrel mislatched durin9 drilling.Core loss 0.2 feet. Run 153 REC (ROD) LENGTH OF RUN (FT.I Run 144 645.1 /100 to (94) 650.4 Run 145 650.41 100 to (lOO) 655.4 IRun 146 655.4 I 98 to (91) 660.7 IRun 142 635.61 91 to (87) 640.9 IRun 143 640.91 100 to (95) 645.1 JOB NO,P5700.05 HOLE NO,BH-8 SHEET NO,21 OF 24 CESCRIPfl ON :COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTJ NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 646.7-650.1 -Shear/alteration zone,rock bleached white-gray,slightly hydrothermally altered,soft and friable.Breccia and clay zone 0.7 feet wide,joints close at 40-75°, carbonate coating. ROCK TYPE Watana (South Bank) DEPTH (FT.) SITE PROJECT Susitna Hydroel ectri c Proj ect CLIENT ALASKA POWER AUTHORITY 660 (571.6) 650 (562.9) 640 (554.3) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY PROJECT Susitna Hydroelectric Project JOB NO.P5700.as REC (RQD) LENGTH OF RUN (FT) Run 160 726.6\100 to (87) 731.2 Run 1591 96 (77) Run 162 736.21 100 to (88) 741.2 Run 164 746.21 100 to (73) 751.3 Run 161 731.21 100 to (96). 736.2 Run 163 741.21 92 to (92) 746.2 [RUn 1651 d~~)_ HOLE NO.BH-8 SHEET NO.24 OF 24 END OF BORING DEseRI PTION :COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAU LTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 731.9-747.1 -Numerous rehea1ed joints. ROCK TYPE Watana (South Bank) Quartz Di orite SITE DEPTH (FT.) 730 1(632.2) 752.4 J---(651.6)-- 750 (649.5) 740 (640.9) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-8 SITE Watana (South Bank)SHEET NO.23 OF 24 DEPTH DESCRIPTION:COLOR,TEXTURE,FOLIATION,,JOINTING,FRACTURING,FAULTI NG,LENGTH REO (FT.)ROCK TYPE ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC OF RUN (RQD)(FT.) Quartz Diorite Run 153 692.2-86 695.0 (71) f------ Run 154 695.0 100 to (74) 700.0 700 700.0-752.4 -Joints closely spaced,planar. (606.2)smooth to rou9h.carbonate coated. Run 155 700.0 100 to (86) 705.1 Run 156 705.1 98 to (83) 710.4 710 614.9) Run 157 71 0.4 100 Run 158 redrilled.to (100) 715.0 Run 158 715.0 83 to (60) 721.3 720 623.5)721.6-724.3 -Joints close.carbonate coating. Core loss 0.2 feet.Run 159 721.3 96 to (77) 726.6 ~.~~1 1 ~~.~~~~,~1 '-~-])'~--] Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Diorite/ REMARKS Dike,felsic. Dike,felsic. • Alteration zone. Fracture/alterati on zone. Alteration zone. Fracture zone. Shear. Shear zone. Shear zone. Shear/alteration zone. Job No.P5700.05 Hole No .._--,BecH,---ooS _ Sheet No._2_of __3_ Di orite Porphyry ROCI<TYPE Quartz Di orite Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Watana (South Bank) 700 680 640 I 11II1 I I I I 560 400 620 I .,.I H-+- 600 540 I .1 II I I 500 3S0 4S0 I 11III I I 1 I I 660 360 460 I 11III I I 1 I I DEPTH (FT.) 5S0 520 440 420 REMARKS TOP OF ROCK S.O' Fracture zone. • Fracture. Shear zone. Shear,hea 1ed. Shear,healed. Shear/fracture zone Dike,granodiorite. Shear. Shear,healed. Job No.P5700.05 Hole No._~B~H-~S,,-----_ Sheet No.~of ~ ROCI<TYPE I nin .....i+o/~Fracture zone. Shear. Client ALASKA POWER AUTHORITY Project Sus itna Hydroel ectri c Project Site Watana (South Bank) 40 60 lSO 340 i60 140 Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUIHORITY Job No.P5700 05 Project Susitna Hydroelectric Project Hole No.BH-8 Site Watana (South Bank)Sheet No._3_of __3_ PERIi4E:ABILITY CORE RECOVERY ROO NUMBER OF DEPTH ELEV.(K)em/lit %%JOINTS PER ROCK TYPE REMARKS1FT.){FT.)10FT 10-6 loA 10"2 20 40 60 eo 2.0 40 GO SO :i "0 15 20 Quartz f---------Diorite 720 1- 740 f------- r---1330 760 END OF BORING f--f----752.4' f--------f-f--- f--f-l~f---- f----- r-----f- t-- f--- f--f---- 1----f------f-f- t-----~ ----- f------,I-f-_._~ I---~----f-- 1---1------f-- f----- I------1-.---- ~.- ._-- liJ ]1 ~)1 :]11 ~j J ~;J ~, '1 J 1 )1 '~-~}~))1 -'-~~J C) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT:ALASKA POWER AUTHORITY JOB NO"P5700.05 PROJECT,Susitna Hydroelectric Project HOLE NO.:BH-12 SITE:Watana (South Bank)SHEET NO.1 OF 26 CONTRACTPR,Interstate Exploration Inc.DRILLING DATES:July 18 TO August 5,1981 LOGGED BY,.K.J.White,R.R.Henschel DATE:September 1981 PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO,BH-12 SHEET NO,2 OF 26 ALASKA POWER AUTHORITY REC (RQD) P5700.05 LENGTH OF RUN tnl JOB NO, DESCRIPTION:COLOR,TEXTURE,FOL.IATlON,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,.1..0ST CORE,CEMENTING,ETC Overburden ROCK TYPE CLIENT DEPTH (FTJ CASING DIAMETER:NW (3.0")L D. CORE DIAMETER:NQ (1.75")O.D. Casing Advancer Diamond Core -Triple Tube SOIL ROCK DRILLING METHOD, 88 (8l) 100 (57) 100(82) o (0)Run 5 Run 3 29.8 to 34.7 Run 6 37.4- 39.8 Run 7 39.8 I 98 to (93) 44.8 37.8 -Heavy iron oxide staining. Light bl ui sh-gray to green ish-gray,ge nera 11 y Run 2 aphanitic to fine grained,contains numerous 27.0 100 angular fragments of argillite ranging from to (55) 0.13 to 1.0 inch (average 0.25 to 0.38 inches)~2~9~.~8--t --1 2-5%of rock.Generally hard. Joint spacing varies from very close to closely spaced in altered zones,to widely spaced in hard zones.Heavily stained with iron oxides, slightly to moderately weathered and open. Penetrative weathering up to 0.25 inches. 27.0-31.8 -Moderately weathered along joints,~ penetrative to 0.5 inches,slightly friable.I ;~~7~I lnn I 36:.12 Andesite 30 (17 .6) 40 (23.5) 27.0 (15.9) o (0) % REC (RQol RUN LENGTH Run 1 0.0- 2.0 DESCRIPTION:COLOR ,TEXTURE,FOl.IATION,JOINTING,FRACTURING,FAULTING1 ALTERATION ~WATER LOSS OR GAIN,CAVING.LOST CORE.l%MENTING,ETC. Overburden of cobbles,boulders of grano- diorite. N3,225,624 E744,515 220° 36° LATITUDE DEPARTURE AZIMUTH DIP ROCK TYPE ELEVATIONS,DATUM MSL,A.S.P.C.,Zone 4 GROUND SURFACE 1975.7 ROCK SURFACE 1959.8 BOTTOM OF HOLE 1505.9 WATER TABLE Depths measured along hole.True depths in (). All angles measured to the core axis. Overburden LOCATION, DEPTH (FT.) NOTES,1) 2) o 10 (5.9) / 20 (11 .8) APPROVED,vI~J1lG(~DATE,February I,1982 50 (29.4) 49.8-51.7 -Fracture zone,very closely spaced fractures,intersecting joints at 50°and 0-20°.Slightly to moderately weathered with penetrative iron oxide staining to 0.75 inches 51.7-52.1 -Yellow-brown sandy/clay layer, 0.25 feet thick,small fragments of highly weathered andesite.Sharp contacts at 50°. Run 8 44.8 to 49.8 Run 9 49.8- 51.9 Run 10 100 (94) 100 (0) 97 (46 / ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.3 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.4 OF 26 100 (60) 96 (84) 100 (82) 100 (80) Run 23 93.5 to 98.5 LENGTH I RECOFRUN (FT)(ROD) -- Run 20 84.6 /100to.(9) 89.6 98.5 to 103.5 Run 21 89.6 97 to (59) Run 22 0 (0) OESCRIPTI ON :COLOR,TEXTI,.lRE,FOLIATION ,JOINTING,FRACTURING,FAULTI NO, ALTERATION,WATER LOSS OR GAIN,CAYI NO,LOST CORE,CEMENTI NG.ETC Run 25 103.5 I 100 to (36) 108.5 0.25 inches. 86.6-87.6 -Open fractures,0-10 0 ,up to 0.5 inches wide,filled with highly weathered rock fragments,locally healed with calcite. Run 27 114.0 to 119.0 108.5-108.7 -Gradational contact. 93.3-108.5 -Joints generally close to moderately closely spaced,tight to partially open.Fresh to moderately weathered with moderate iron oxide staining.Minor clay coating. 97.2-98.1 -Fracture zone,very closely spaced joints,slightly weathered,iron oxide stained, open.Moderately hard. 99.5-99.8 -Felsic dike,medium gray,very finelRun 24 grained,very hard. ROCK TYPE Andesite DEPTH (IT) (~~~9)i 8------------------1 Run 26 110 Oiorite Light to medium gray,medium grained (64.7)crystalline rock.Hard to very hard,fresh to 108.5 slightly weathered along joints with minor to iron oxide staining.114.0 100 (58.8) 90 (52.9) REC (ROD) 94 (34) 97 (63) LENGTH OF RUN (FT) 75.1 to 79.6 Run 19 79.6 to 84.6 Run 14 67.2-1100 69.5 Run 15 69.5-84 100 (78) Run 10 51.9 I 97 to (46) 57.3 Run 11 57.3-100 59.4 (19) Run 12 59.4 100 to (42) ~ Run 13 62.0 1100 to (46) 67.2 I I OEseRI prl ON:COLOR,TEXTURE,FOLIATiON ,..JOINTING,FRACTURING,FAULT!NO, ALTERATION,WATER LOSS OF!GAIN,CAVING,LOST CORE,CEMENTING,ETC 76.5-77.2 -Shear,15 0 _20 0 ,thin clayey breccial Run 18 coating. 70.0-73.0 -Shear/fracture zone,joints very close to closely spaced at 40 0 -60 0 ,open, moderately weathered.Friable locally,iron oxide stained,some sandy clay. 83.6-93.3 -Shear/alteration zone,slightly bleached hydrothermally.Numerous fractures at 30°-40°.Heavy iron oxide staining, moderately hard to friable locally. 85.1-86.6 -Shears,sandy clay gouge to 54.1-54.4 -Shear.20 0 ,0.25 inches wide.Clay layer intruded by quartz,friable. 55.4 -Shear,35 0 ,0.25 inches wide.Clay layer containing breccia,soft,friable. 56.1 -Shear,20°,0.25 inches of sandy clay breccia. ROCK TYPE Andesite DEPTH (FT) 80 (47.0) 60 (35.3) 70 (41.2) '1 11 j '!1 ~N ~~.j )~')'\1(I ~I --' --~-l ~)_---)]---l '''''~.._C~__!]Cc ,)-0 -J 1 .)~) ACRES AMERICAN INCORPORATEO -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project JOB NO.P5700.05 HOLE NO.BH-12 CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project JOB NO.P5700.05 HOLE NO.BH-12 SITE Watana (South Bank)SHEET NO.5 OF 26 SITE Watana (South Bank)SHEET NO.6 OF 26 DEPTH (FT.)ROCK TYPE ~:COLOR,TEXTURE,FOUATION,JOINTING,FRACTURING,FAULTING. ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC, LENGTH OF RUN (FT) REO (RClD) DEPTH (FT)ROCK TYPE DESCRIPTION:COLOR,TEXTURE l FOLIATION ,JOINTI NG,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT) REC (ROD) 120 (70.6) Diorite 118.7-124.7 -Felsic dike,medium blue-gray, very fine grained.Porphyritic locally, phenocrysts to 0.13 inches diameter,hard. Run 271 100 (60) Run 28 119.0 1100 to (74) 124.0 150 (88.2) Diorite 152.5 -Dike,20"-30",dark gray,very fine grained,0.5 inches wide,hard. Run 33 POO(83) Run 34 149.7 1 100 to (66) 154.9 130 (76.4) 140 (82.3) Run 29 126.1 -Shear,50",silty clay gouge less than 1 124 .0 1 100 1.0 inch.to (43) 127.0 -Shear,15°,0.1 inch gouge.129.1 Run 30 129.1 1 98 to (42) 134.5133.8-134.5 -Fracture zone,fractures very closely spaced,50·,with carbonate coating. Run 31 134.51 100 to (96) 139.5 Run 32 139.51 96 to (88) 144.6 160 (94.1) 170 \99.9) Run 35 154.9 1 100 to (67) 159.7 159.7-162.4 -Andesite dike,medium green- gray,very fine grained.Numerous very thin quartz stringers at 45°_60°.Very sharp Run 36 100 contacts.(37) 162.4 -Carbonate filling at contact,less R 37 than 0.06 inches thick,hard and brittle.un 161.2 I 94 to (69) 166.0 Run 38 166.0 1 97 to (86) 169.9 -- Run 39 169.9 I 100to(100) 174.9 Run 33 144061100 to (83) 149.7 180 (105.8) 179.2-179.33180.5-180.6 Felsic dikes,light tan,very fine graine ,hard. Run 40 174.9 1100 to (100) 179.9 Run 411100(78) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO BH-12 SHEET NO.7 OF 26 PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.8 OF 26 DEPTH (FT.)ROCI(TYPE DESCRIPTION:COLOR,TEXTURE I fOLIATION,JOINTI Nt;,FRACTURING,FAULT]NG, ALTERATION,WATER LOSS OR GAl No,CAVI NG,LOST CORE,CEMENTI NG I ETC. LENGTH OF RUN (FT.) REG (ROO) DEPTH (FT.)ROCK TYPE: DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NCi, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT) REG (RQD) 100 (51) 100 (69) 100 (69) 98 (84) 100 (73) Run 51 Run 50 224.9 to 229.8 Run 47 Run 48 214.9 to 219.8 Run 49 219.8 to 224.9 229.8fracturesIto layer,0.25 235.0 232.9-234.2 -Shear/fracture zone, very closely spaced.Clay/breccia inches wide,friable. 234.2-235.0 -Alteration zone,bleached white, altered hydrothermally,hard.I I -4 212.6-213.4 -Shear/alteration zone,moderat~ to completely altered hydrothermally,very closely fractured but still intact.Original structure and texture of diorite preserved. 214.3-214.4 -Two clay seams 40°and 70°,0.13 inches wide. .Diorite 230 (135.2) 220 (129.4) 100 (71) 100 (78) 100 (48) 100 (85) 100 (44) Run 45 199.9 to 204.9 Run 44 195.1 to 199.9 Run 43 189.9 to 195.1 Run 41 179.9 to 185.0 Run 42 185.0 to 189.9 193.5 -Joint,30°,slickensides. 180.6-183.6 -Alteration zone,bleached, sl ightly altered hydrothermally. 197.2-197.8 -Shear zone,50·,slightly friable,clay/breccia layer,0.38 inches wide,stiff,slightly plastic. 197.7-197.8 -Brecciated zone,0.25 inches wide,clay seam at 50°. Oi orite 200 (ll7.6i 190 (111.7) 210 (123.5) 207.4-208.3 -Felsic dike,light gray,very fine grained. Run 46 204.9 I 98 to (90) 209.8 Run 47 209.8 I 100 to (51) 214.9 240 (141.1 Run 52 235.0 I 100 to (75) 240.1 Run 53 240.1 I 100 to (61) 245.3 ;;)l ~j ~]~l )'1,:, "1 '~~]").~~"l 1 )"'1 )]'.~'J ;J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.9 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.10 OF 26 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR 1 TEXTURE,FOUAT10N ,JOI NT1NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN 1FT.' REC (RQO) DEPTH (FT.]ROCK T'r'PE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING;LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.) REC (ROD) Run 59 270.2 I 100 273.7-276.1 -Shear/alteration zone,slightly I to (65) altered hydrothennally.Fractures very 275.3 closely spaced,friable,carbonate coating. Run bOI100 (QT Run 61 Run 56 255.5 1100 to (94) 260.2 Run 57 260.2 I 100 to (66) 265.3 97 (25) 100 (69) Run 62 279.8 to 284.5 Run 61 276.2 to 279.8 273.8 -Shear,30·-35·,less than 0.13 inches.Soft,plastic,sandy clay. 274.2-276.4 -Core badly broken by drilling,pieces slightly friable. 276.2-280.6 -Joints very close to closely spaced. Run 63 284.5 1 100 to (70) 289.7 Run 64 289.7 I 100 to (98) 294.2 Run 65 294.2-100 296.5 (76) Run 66 296.5 82 to (77) 299.8 Run 67 299.8 I 100 to (79) 304.5 Run 68 304.5 I 100 308.6-309.4 -Fracture zone,joints very I to (80) closely spaced at 20·,50·,and 80·.309.4 Diorite 290 (170.5) 280 (164.6) 300 (176.4) 100 (73) 98 (65) 100 (80) Run 58 265.3 to 270.2 Run 55 250.2 to 255.5 Run 54 245.3 to 250.2 251.8 -Joint,60·,clay and rock fragments. Diorite 270 (158.8) 260 (152.9) 250 (147.0) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO..P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Sus itna Hydroe 1ectri c Proj ect SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.11 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.12 OF 26 310 J Diorite (182.3) Run 75 I I Run 74 335.1 1100 to (47) 340.0 93 (39) Run 79 358.9 1 98 to (47) 364.2 Run 80 364.2 1100 to (65) 369.3 Run 81 369.3\100 to (94) 374.6 Run 78 353.2 to 358.9 LENGTH I RECOFRUNIFl)(ROO) Run 75 340.0 I 94 to (35) 343.6 Run 76 343.6 1100 to (85) 348.3 Run 77 348.3 1100 to (69) 353.2 366.9-367.6 -Fracture zone,joints very closely spaced. DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 343.0-343.8 -Fracture zone,joints very closely spaced. 355.8-362.6 -Alteration zone,bleached white, slightly to severely altered hydrothermally. Joints very close to closely spaced,moderatel hard to very friable.Sharp contact at top, gradational at bottom. 355.9-356.9}358.0-358.9 Severely altered zones. 362.1-362.6 -Several joints at 40°with minor clay and rock fragments,less than 0.06 inches thick. ROCK TYPE Di orite DEPTH (FT.l 360 (211 .7 370 (217.6 350 (205.8 REo (RQD) LE"NGTH OF RUN 1FT) Run 70 315.6 I 100 to (83) 320.4 Run 69 309.4 I 97 to (73) 315.6 Run 73 330.0 1100 to (45) 335.1 Run 72 325.0 1100 to (58) 330.0 Run 71 320.41 100 to (65) 325.0 DESCRIPTION:COLOR,TEXTURE:,FQUATION,JOINTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAl N,CAVING,LOST CORE,CEMENTING,ETC. 335.6-336.8 -Core broken by drilling. 324.7-325.0 -Fracture zone,joints very closely spaced. 332.7-332.9 -Fracture zone,joints very closely spaced. ROCK TYPE DEPTH (FTJ d~8.0 330 (194.0) 320 (188.2) 1 l II .~j ~'It ~1 1 J ~ -).'J 'J ]c_''")c,~--1 ),C~__-_)----)----,---J ,.0C'"-----1 -1 -1 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT JOB NO.P5700.05 HOLE NO.BH-12 SHEET NO.13 OF 26 CLIENT ALAS KA POWER AUTHORITY ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-12 SITE Watana (South Bank)SHEET NO.14 OF 26 DEPTH OESCRIPTI ON :COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG I LENGTH REC ROCK TYPE OF RUN(FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,.LOST CORE,CEMENTING.ETC 1FT.}(ROD) Di orite Run 90 404.2 100 to (100) 409.1 410 Run 91(241.0) 409.1 100 to (100) 414.2 Run 92 414.2 100 to (92) 419.2 420 Run 93(247.0)419.2 100 to (100) 424.4 Run 94 424.4 100 to (92) 429.4 430 (252.8)Run 95 429.4 100 to (58) 434.7 Run 96 434.7 100 14~g 7 (86) REe (RQD) LENGTH OF RUN (FT.) Run 83 100(88 Run 84 380.4 100 to (87) 385.0 Run 85 385.0 1100 to (88) 389.8 Run 81 I 100 (94) Run 82 374.6 1100 to (100) 379.6 Run 86 389.8 1 98 to (96) 395.0 f=--Run 87 395.0 I 100 to (42) 398.3 Run 88 398.3 100 to (0) 401.4 ~un-8~9-+--~ 401.4 29 to (0) 404.2 IRun 9011001100 DESCRIPTION:COLOR,TE"XTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC. 389.3-389.8 -Fracture zone,fractures very closely spaced. 387.8-387.9 -Fracture zone,fractures very closely spaced. 383.1-383.4 -Fracture zone,fractures very closely spaced. 396.1-404.2 -Fracture zone,fractures and joints very closely spaced,partly drillin9 induced. 397.0-397.3 -Quartz vein. ROCK TYPE Watana (South Bank) Oiorite SITE PROJECT Susitna Hydroel ectric Project DEPTH (,FT) 400 (235.2 390 (229.3)' 380 (223.4) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.15 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.16 OF 26 DEPTH (fT.]ROCK TYPe:DESCRIPTION:COLOR I TEXTURE,FOLIATION ,JOiNTING,FRACTURING,FAULTI NG, ALTERATION,wATER LOSS OR GAIN,CAVI NG 1 LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT) "EC (ROD] DEPTH (FT.l ROCK TYPE DESCRIPTION COLOR,TEXTURE,FOLlATION,JOINTING,FRACTURING.FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. LENGTH OF RUN (FT.l "EC (ROD) 96 (19) 100 (8) 100 (52) 100 (18) 100 (81) 100 (63 ) 100 (100) Run 10< Run 10E 494.3 to 499.5 Run 10 489.2 to 494.3 Run 10E 484.1 to 4&9.2 Run 105 478.8 to 484.1 Run 103 469.5 to 474.6 Run 104 474.6 to 478.8 476.7 -Joints,60°-65°,sandy clay filling, slight chlorite coating. 477.9-482.0 -Shear/alteration zone,slightly to moderately altered hydrothermally.Breccia , and gouge material.Soft to moderately hard,~--+------­ friable. 480.8-480.9 -Possible healed shear,1.0 inch of dark gray,very fine grained material. 483.2-483.7 -Joint,15°_20.,quartz/carbonate coating with slickensides. 483.5 -Joint,60°,sandy clay filling, slickensides. 484.6 -Shear/alteration zone,slightly to moderately altered hydrothermally,soft to moderately hard.Shears,60°_70°,clay/sand breccia. 486.1-490.6 -Moderately hard,joints very close to closely spaced. 487.9-488.6 -Shear zone,55°_70°,with approximately 0.5 inch spacing.Numerous very thin shears with clay gouge. 490.6-519.3 -Shear/alteration zone,slightly to moderately altered hydrothermally. Numerous very thin shear planes,brecciated but healed with calcareous sandy clay. Moderately hard to soft,friable.Joints moderately closely spaced,chlorite coating. 50%of joints healed with carbonate. Irregular patches of red staining. 473.9-474.0 -Shear,40°,less than 0.1 inches of breccia.Offset by 0.25 inches,healed. Moderately hard. 470.3 -Shear,85°,0.5 inches wide,sandy clay filling,chlorite coating,slickensides. Diorite 490 (288.1) 500 (294.0) 480 (282.2) 470 (276.4) 96 (31) 100 (26) 100 (24) 100 (86) 100 (62) 100 (71) 100 (43) Run 96 434.7 to 439.7 Run 97 439.7 to 444.8 Run 101 459.5 to 464.5 439.3-439.7 -Fracture zone,joints very closely spaced at 40°. Run 100 457.7-463.2 -Shear/fracture zone,joints verYI4i~·6 closely spaced,carbonate filling,chlorite/459 5 talc coating,slickensides.. 463.2-465.2 -Alteration zone,bleached, slightly altered hydrothermally,hard. 464.5-465.2 -Shear zone,very thin shears ~+---~ at 60°-70°,calcareous clay filling,Run 102 brecciated but intact.464.5 to 469.5 449.8-454.8 -Shear/alteration zone,rock bleached,slightly to severely altered hydro- thermally.IRun 99 449.8-451.8 -Green-gray,granular texture 449 5 moderately hard.Possible shear planes to' present.454.6 451.8-454.8 -Bleached zone,quartz rich, very few mafics,very hard. 444.8-448.2 -Fracture zone,joints and fractures very closely spaced at 20°,40°,and ~-+-----l 50°,partly open to tight,coated with yellow-Run 98 brown clayey material.444.8 to 449.5 Oi orite 440 (258.7) 460 (220.5) 450 (264.6) l 11 ~,."l ~j 1 ~11 3 "'ll. 'j -.\5i :'f~ ~-l 1 1 '.'J c,cc~··l 1 ......•}]J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK D R IL II N G REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.17 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.18 OF 26 DEPTH (FT.) 510 (299.9) ROCK TYPE Diorite DESCRIPTION:COLOR,TEXTURE,fOLIATION ,.101 NTING,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. 498.6-499.1 -Fracture/alteration zone, yellow-green color,very closely spaced joints at 60°healed with carbonate. Feldspars stained but hard. 500.5 -Alteration zone.2.0 inches wide, carbonate healed joint at 80°.Hard. 507.2-507.6 -Fracture zone,joints very closely spaced at 40°_70°,silt/clay coating. 509.1 -Joint,30°,silt/clay coating. 511.2-512.8 -Joints,healed with carbonate. 512.8-513.5 -Shear/fracture zone,very closely spaced joints.Shear,60°-70°, 0.5 inches breccia,partially healed with carbonate. 511.2-571.6 -Joints,closely spaced with zones of very closely spaced,chlorite coating carbonate healed,tight,up to 2 feet long. LENGTH OF RUN (FT.) Run 109 499.5 to 503.7 Run 11 0 503.7 to 509.0 Run 111 509.0 to 514.1 Run 112 514.1 to 519.1 REC (ROD) 100 (100) 100 (91) 100 (67) 100 (100) DEPTH (FTJ 540 (317.5) 550 (323.4) ROCK TYPE Diorite DEseRI PilON:COLOR,TExTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING~_LOST CORE.CEMENTING,ETC. 532.8 -Alteration zone,slightly altered hydrothermally,1.0 inch wide. 533.8 -Shear,60°,0.5 inches of breccia/ gouge. 536.7 -Shear,0°_10°,up to 0.3 inches breccia/gouge. 538.1 -Shear,25°,less than 0.1 inch of gouge. 542.3-545.9 -Felsic dike,light gray,fine grained,10%mafics,5-15%quartz,5%green feldspar phenocrysts.Very closely spaced joints,tight.Upper contact 50°,fractured, sheared,slickensides.Lower contact 30°, probably sheared,trace clay/silt. 545.9-549.2 -Fracture zone,very closely spaced joints,tight. 548.4 -Joint,60°,clay coating. 549.2 -Joint,80°,clay coating. LENGTH OF RUN 1FT.) Run 116 533.4 to 538.4 Run 117 538.4 to 543.4 Run 118 Run 119 544.5 to 549.7 Run 120 REG (ROD) 100 (72) 100 (52) 91 In' 100 (62) 549.7 to 554.7 Run 121 554.7 to 559.7 520 (305.8) 530 (311.6) 520.5-528.6 -Joints,40°,closely spaced, healed with rusty orange carbonate.Slightly altered hydrothermally to 1.0 inch either side 10-20%of feldspars altering to clay.Hard, tight. 530.9-538.8 -Fracture/shear zone,very closel\ spaced joints at 20°and 70°.Most joints healed and tight. 531.1 -Shear,20°,0.1 inches breccia/ gouge. 531.6 -Shear,10°,0.5 inches breccia, faint slickensides. Run 113 519.1 to 523.2 Run 1141 523.2 to 528.5 Run 1E 528.5 to 533.4 100 (100) 94 (72) 100 (48) 560 (329.3) 553.3 -Alteration zone,slightly altered hydrothermally,10%of feldspars altering to clay,hard. 553.7-556.7 -Felsic dike (?),light gray, fine grained to aphanitic with fine to medium grained phenocrysts,5-15%mafics,5-15% feldspar.Tight joints very closely spaced. Upper contact,40°,gradational 2.0 inches, tight.Lower,50°,sheared with 0.5 inches of breccia partially healed with carbonate. 557.0 -Joint,30°,silt/clay coating,0.25 inches of alteration,10%of feldspars alterfugRun 122 to clay.559.7 565.7 -Joint,60°,yellow orange carbonate/to silt coating.564.9 98 (54) 100 (92) 100 (62) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.19 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.20 OF 26 DEPTH (FT)ROCK T'(PE DESCRIPTlON COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG,~~N~J~REC ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FT)(ROD) DEPTH (FT)ROCK TYPE ~CRIPTI ON :COLO R,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG,6~N2~~I REC ALTERATION,WATER LOSS OR GAIN,CAVI Nu,LOST CORE,CEMENTING,ETC,(FT.)(RQD) 100 (87) 100 (45) 100 (98) 100 (38) 100 (54) 100 (92) 100 (100) Run 137 625.0 to 628.6 13R1 Run 133 604.9 to 609.8 Run 136 620.1 to 625.0 Run 134 609.8 to 615.0 Run 131 596.0 to 599.8 Run 132 599.8 to 604.9 Run 135 615.0 to 620.1 621.4 -Shear,60 0,0.1-1.0 inches gouge. 626.6 -Shear zone.1.0 inch breccia/ gouge. 626.8 -Shear,40·,carbonate,gouge. 619.0 -Shear,25 0 ,clay/gouge coating. 616.2 -Shear,40-70·,l.O·to 2.0 inches brecci a/gouge. 613.2-613.5 -Shear,80 0 ,breccia/gouge. 614.3 -Shear,30·,0.5 inches breccia/ gouge. 610.0-613.6 -Moderately altered,20-30% of feldspars altered to clay. 596.0-596.7 -Breccia,healed. 598.2 -Joint,80 0 ,talc coating. Quartz Diorite 620 (364.6) 610 (358.7) 600 (352.8) I I rr1T?41 1nnr Run 13 589.81 100 to (75) 596.0 Run 12 1585.0 100 to (88) 589.8 Run 123 564.91 100 to (61) 570.0 Run 125 570.31 71 to (45) 575.9 Run 1311100(92) 566.0-566.2 -Alteration zone,10%feldspars altering to clay. 567.6 -Alteration zone,1 inch thick,slight hydrothermal alteration,10%feldspars altering to clay. Oi orite 571.0-586.1 -Shear/fracture zone,joints very closely spaced,many carbonate healed. 571.4 -Zone of light gray-green,fine grained material 0.5 inches wide,sharp contacts at 70 0 •Offset by 0.2 inches wide carbonate filled shear at 40 0 •Either 575.9 silty clay layer or altered felsic dike.~338.6)~Quartz Light gray,fine to medium grained crystalline Run 126 Diorite rock.Mafic content,variable averaging 20-575.9-33 30%,'10-15%quartz.Slightly altered overall.578.0 (0) Run 127 61578.0-579.8 -Core loss 0.8 feet.578.0-(22) 578.6 -Shear,25 0 ,2.0 inches of breccia i:;QQ partially healed with carbonate and 0.1 ~ inch of gouge.Run 12 582.0 -Shear 50 0 1.0 inch breccia/gouge.579.8 96, ,to (44) 582.0-586.1 -Alteration zone,bleached to 585.0 yellow-orange hydrothermally,hard to moder- ately hard.Joints,100 and 70 0 -80 0 with clay ~I coating.I 586.1-605.9 -Joints,closely spaced,healed with carbonate,tight. 588.0-656.5 -Alteration zone,slightly to moderately altered.Feldspars bleached to yellow-gray.Very close to closely spaced joints.Minor sulphide'mineralization.Hard. 590.2 -Shear,20 0 ,clay/silt coating, faint slickensides. 595.8 -Shear,20·,0.1-0.3 inches of gouge. 596.0-596·77 597.8-598.5)Alteration zones,moderately altered hydrothermally,50%of feldspars altering to clay. 570 (335.2 ) 580 (341.0) 590r346.9) '1 ~,]1 l 1;]'1l'}-R 1 ;'j ~').r>.,).~~],.-.._,,)'1 '-~-"]-]1 1 ~--1 ..~]~.,_.~.. ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO t NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700,05 CLIENT ALAS KA POWER AUTHORITY JOB NO,P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.21 OF 26 SITE Watana (South Bank) HOLE NO,BH-12 SHEET NO.22 OF 26 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLO R,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN 1FT:) REe (RQD) DEPTH (FTJ ROCK TYPE DESCAIPTI ON;COLOR,TEXTURE,FOLIATlON,JOINTING,FRACTURING,FAULT]NG, ALTERATION,WATER LOSS OR GAIN,CAVING._LOST CORE,CEMENTING,ETC LENGTH OF RUN tFT.) REe (RQO) 656.8 t-- (386.2)Granodiorite 654.5-655.7 -Shear,80",breccia/gouge. 651.6:656.5 -Moderately altered,fe1dsparsiRun 143 a1terlng to clay. 649.81 100 to (88) 655.0 100 (77) 100 (88) 100 (94) 100 (69) 100 (92) 100 (100) 100 (100) Run 145 659.8 to 665.0 Run 151 688.2 to 693.4 Run 148 673.0 to 678.2 Run 1501 683.2 to 688.2 Run 147 669.8 to 673.0 Run 146 665.0 to 669.8 683.4-688.3 -Alteration zone,altered hydro- thermally with very thin to thin zones of bleached and altered rock with sulphide alteration. 684.2 -Joints,20",clay coated,possibly sheared. 687.1-688.1 -Shears,40.70 0 ,very closely spaced,0.5-1.0 inch breccia/gouge. along healed joints. 656.8-681.4 -Joints,close to moderately closely spaced,most healed with carbonate. 660.3-662.0 I 662.9-663.5)Alteration zones,10-20%of feldspars altering to clay,moderately hard, 674.0 -Joint,35 0 ,penetrative alteration of 0.5 inches. 674.1 -Within 1.0 inch zone,color has changed from pink (fresh rock)to light gray with less than 5%mafics and altered feldspars giving appearance of two rock types in texture and composition.I " I 677 .4-678.5? 681.2-681.4,)Alteration zone, moderate hydro- thermal alteration of feldspars to c1av. Rock description as above. 681.4-695.6 -Joints,close to very closely spaced,many healed with carbonate. Granodiorite Quartz Diorite 670 (394.0) 690 (405.7) 680 (400.7) 681.4. (400.7) 100 (65) 100 (80) 100 (45) 100 (100) 639.8 to 645.0 Run 1441 655.0 100 to (92) 659.8 Run 140 634.7 to 639.8 Run 142 645.0 to 649.8 Run 138/106(73 clay coating. clay coating. 0.3 inches of gouge. 0.5 to 1.0 inches wide"Run 141 633.5 -Shear,70 0 ,0.1 inches of gouge, 633.9-639.5 -Moderately altered,feldspars breaking down to clay. 634.0 -Shear,60 0 ,2.0 inches breccia/ gouge. 634.2 -Shear,15 0 , 635.2 -Shear,60", 635.7 -Shear,50", 637.4 -Shear,40", breccia and gouge. 638.1 -Shear,50 0 ,clay coating. 639.1 -Shear (?),30",clay coating. 643.2 -Shear (?),60",clay coating. 643.6 -Shear,30",0.5 inches wide,0.1 inches of gouge along a healed shear of dark gray igneous material and carbonate. 644.0 -Shear,50",clay coating,offsets a very thin vein of dark gray igneous material,0.1 inches wide. 631.3 -Shear,45 0 ,coating of clay gouge.IRun 139 629.7 to 634.7 Light pink-gray,fine to medium grained cry- stalline rock.Mafics 20-30%,primarily horn- blende/biotite,5-15%quartz,and pink,green, and white feldspars.Hard,generally fresh to~~ slightly hydrothermally altered.Alteration Run 14 100rlnn) Quartz Diorite 660 388.1} 650 (382.2) 640 (376.3) 630 (370.4) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroe 1ect ri c Proj ect PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO BH-12 SHEET NO.23 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.24 OF 26 DEPTH (FT,) 700 (411 .6) ROCK nPE Quartz Diorite DESCRIPTION:COLOR,TEXTURE,FOLIATiON I JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC. 687.1-689.0 -Alteration zone,moderate hydro- thermal alteration of feldspars to clay. 692.1-692.3 -Shear,60·,clay coating. 693.5-695.3 -Shear/alteration zone.Very closely spaced shears (3)at 60-90·with 0.5 inches of gouge. 695.6-706.5 -Joints close to moderately closely spaced. 700.5 -Alteration zone,1.0-2.0 inches pene- trative alteration.25%feldspars altered to rusty-orange clay. LENGTH OF RUN (FT) Run 152 693.4 to 698.4 Run 153 698.4 to 703.6 REC (RQD) 100 (48) 96 (96) DEPTH (FT,) 730 429.2) ROCK TYPE Quartz Diorite OEseR I FTiON ;COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER lOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LE:NGTH OF RUN (FTi Run 158 724.4 to 729.6 Run 159 729.6 to 734.8 REC (RQol 100 (100) 100 (100) Run 1641 100 (94) 710 (417.5) 720 (423.4) 703.4-704.8 -Alteration zone,moderately altered. 703.7 -Shear,40·,0.1 inches clay and ta lc (7). 704.1 -Vein,70·,0.5 inches wide,light gray,aphanitic,vuggy. 706.5-711.7 -Joints close to very closely spaced,healed,tight. 711.7-738.3 -Joints close to moderately closely spaced,most are healed with carbonate,tight. 712.3-712.5?Alteration zones,moderately 713.1-713.4j altered hydrothermally. 714.3 -Shear, 25°,0.1 inches of clay gouge. Run 154 703.6 to 708.8 Run 15~ 708.8 to 713.9 Run 156 713.9 to 719.2 Run 15' 719.2 to 724.4 100 (98) 100 (97) 100 (100) 100 (100) 740 (435.1) 750 (441.0) 735.1-751.5 -Alteration zone,moderately altered hydrothermally,numerous shears. 735.1 -Shear,60·,0.5 to 1.0 inch of breccia/gouge,slickensides. 736.3-736.6 -Shear,25·,breccia with minor gouge. 738.3-790.2 -Joints closely to very closely spaced,most joints are tight,carbonate healed,clay coating on many. 740.3 -Shear,40·,clay coating. 742.6 -Shear,80·,1.0 inch of breccia/gouge. 743.9 -Shear,30.-40 9 ,1.5 inches wide breccia/gouge. 744.5-744.8 -Core broken by drilling,pieces average 1.0 inch.Clay coating,possible shear. 746.8-747.0 -Shear,60·,0.3 inches of gouge, 2.0 inches of breccia,slickensides. 749.3 -Shear,35·,clay coated. 750.2 -Two shears,very closely spaced at 10·" breccia/gouge in a 1.0 inch wide zone, slickensides. Run 160 734.8 to 739.8 Run 161 739.8 to 744.8 Run 162 744.8 to 749.8 Run 163, 749.8 to 754.9 100 (100) 100 (64) 100 (80) 100 (90) ~~'it it! )" )]1 -~1 <-}1 J ~-1 ))l ) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORk DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORk DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.25 OF 26 SITE Watana (South Bank) HOLE NO.BH-12 SHEET NO.26 OF 26 REC (ROD) LENGTH OF RUN (FT.) Run 172 79.0.1 I 98to~(96) 795.1 Run 173 795.11 100 to (82) 798.9 ~ END OF 80RING DESCRIPTION:COLOR,TEXTURE,fOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAYI NG,LOST CORE,CEMENTING I ETC 797.3-798.9 -Fracture zone,joints very closely spaced.Slight to moderate hydro- thermal alteration. 790.2-797.3 -Joints close to moderately closely spaced. ROCK TYPE Quartz Diorite DEPTH (FT.) 790 (464.5) 798.9 (469.8) _800 (470.4) REC (ROD) 18~) 96 (96) 100 (94) 100 (100) 100 (100) LENGTH OF RUN (FT.) Run 165 759.9 to 764.9 Run 164 754.9 to 759.9 DESCRIPTION;COLOR,TEXTURE,FOLlATlON,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.ROCK TYPE Felsic Dike Quartz Diorite DEPTH (IT) 763.6~449.0)Light gray yellow,aphanitic to medium grained 5-10%dark gray green phenocrysts,5-10%rustyt--~-----4 orange feldspar phenocrysts.Moderately hard.Run 166 763.6-764.1 -Healed shear,30 0 ,resheared 764.9 with 0.3 inches of gouge.7~~.5 768 5 768.0 -Shear,30 0 ,irregular,breccia/gouge.un (451 :9)Quartz Rock description as above.7~~.5 770 Diorite 768.5 _Shear,80 0 along lower contact,2.0 p7""6""'....,,8'+-I (452.8)inches wide breccia and gouge.Run 168 770.4 -Shear,40°,clay coating with possible 769.8 talc.to 775.0 760 (446.9) 775.9 -Shear,5D o ,0.1 inches of gouge, s1ic kens ides. Run 169 775.0 1100 to (75) 780.1 780 (458.6)781.3-781.6 -Shear,40 0 ,shear planes very closely spaced,breccia,minor gouge, moderately altered hydrothermally. 786.9-787.5 -Alteration zone,moderately altered. 787.2 -Shear,60 0 ,0.5 inches of breccia/ gouge. 788.3-788.9 -Alteration zone,moderately altered hydrothermally. 788.3-788.4 -Two shears,very closely c:n:=l,..~r1 :::1+7(\0 loce:+hrin ()1 in,-.hprI=:nnllnp Run 170 780.1 1100 to (74) 785.1 Run 171 785.1 I 98 to (72) 790.1 ,- 1 \ r l . l l r - APPENDIX C DEVIL CANYON DIAMOND CORE DRILLING LOGS -1 -1 c--)c....).r.].._]c...•.,] ..~-1 ---J ··---1 ,---·'·1 '-"1 ~l ----1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT,ALASKA POWER AUTHORITY JOB NO.:P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric ProjectPROJECT, SITE: Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.:BH-1 SHEET NO.1 OF 24 SITE Devil Canyon (North Bank) HOL E NO.BH-l SHEET NO.2 OF 24 CONTRACTOR:The Dri 11 i ng Company LOGGED BY,K,,1.White,M.P.Bruen REe (RQD) 85 92 (30) 86 (80) (78) Run 5 31.3 to 35.0 LENGTH OF RUN (FT) j{un 4 26.2 to 31.3 Run 3 20.8 to 26.2 bedding/foliation at 0°_30°,less than 1 inch wi de,folded,stretched,1ess fractured than veins,contacts generally tight. 11.8-80.1 Joint spacing generally close, generally planar and smooth,iron oxide stained minor quartz and carbonate coating. 11.8-14.9 Core loss of 0.6 ft.Core broken by drilling,clay on some joints.' 17.0-20.0 No drilling water return. 17.4-17.9 Core broken by drilling,clay on some joints. 20.8-35.0 Core loss of 1.8 feet. DESCRIPTION:COLOR,TEXTURE,FOLIAT'ON,JOINTI.~G,FRACTURING,FAUL.T!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,,LOST COREl CEMENTING,ETC 33.0-33.7 Core broken by drilling zone of quartz stringers 0.5 in.thick. ROCK TYPE Argi 11 ite DEPTH tFTJ 30 (27.6) % REC (RQol CASING DIAMETER,NW (3.0")1.D. CORE DIAMETER,NO (1.75")0.0. DRILLING DATES,.August 23 TO August 31,1980 DATE,July 1981 Sandy gravel with layer of silt and scattered cobbles.Not sampled. ~:COLOR ,TE:XTURE,F"OL.IATION.,JOINTING,FRACTURING,FAULTING,I RUN ALTERATION.WATER LOSS OR GAIN,CAVING,LOST COR£,CEMENTING,ETC.LENGTH N3,223,408 E615,930 225° 67° Cas i ng Advancer Diamond Core -Triple Tube SOIL ROCK LATITUDE DEPARTURE AZIMUTH DIP ELEVATIONS,DATUM MSL,A.S.P.C.,Zone 4 GROUND SURFACE 1413.7 ROCK SURFACE 1402.8 BOTTOM OF HOLE 723.1 WATER TABLE 1221.7 (11-21-80) Depths measured along hole.True depths in (). All angles measured to the core axis. ROCK T'l'PE Overburden DEPTH (fT.) LOCATION: DRILLING METHOD: NOTES,1) 2) 0.0 36.7 Bedding/foliation is at 20°.Rock does not tend to break along bedding/foliation. Run 6 35.0 to 40.0 100 (80) (52) Run 8,100 (90)45.0 to 49.0 40.0 to 45.0 lWn giloo 49.0 (45) to 53.2 f-Ril-n71 100 Interbedded argillite and graywacke.ArgTll1tE as above,with very thin beds of graywacke, light to medium gray,20 percent to 30 percent fine to medium sand in argillaceous matrix, grains elongate parallel to bedding/foliation generally at 20°,foliation is poorly developed.Fresh,hard and well indurated. Joint spacing is generally close,generally planar and rough,iron oxide stained,some carbonate and quartz filling. 52.8-53.5 Clay on joint surface at 20°. Arg iTl ite/ Graywacke 40 (36.8)1 50 (46.0) 42.5 (39.1)Run 1 11.8 I 85 to (23) 15.8 Run 2 15.8 1100 to (86) 20.8 DATE:Februa ry I,1982/~/LY!IJ~·v"7//(./l----APPROVED, 20 (18.4) 10 (12) (~6:~~Argillite I Medium to dark gray,fine grained,nonfoliated'I I to weakly developed foliation parallel to bedding,20°.Fresh to slightly weathered, hard,well indurated.Joints generally close spaced with iron oxide staining.Zones of quartz veins and stringers,minor sulfide mineralization. 11.8-30.8 -Numerous quartz veins and stringers,highly folded bedding.Quartz veins (12.7-13.7,20.8-22.2,27.1-27.5)are highly fractured but tight,vuggy,cross- cutting !SH.f~jation,contacts are irregular and rough./N<irtz stringers are parallel to r ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project SHEET NO.3 OF 24 SHEET NO.4 OF 24 P5700.05 BH-l JOB NO. HOLE NO. ALASKA POWER AUTHORITY Susitna Hydroelectric Project Devil Canyon (North Bank)SITE CLIENT PROJECT P5700.05 BH-lHOLENO. JOB NO. Devil Canyon (North Bank)SITE I I Argill He/I Graywacke Run 19[82 90.0 (39) to 94.4 LENGTH RECOFRUN(ROO)(FT)-_.. Run 18 83 84.0 (57) to 90.0 DESCRIPTION;COLO R,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING.LOST CORE,CEMENTING,ETC 88.8-101.8 Quartz veins highly fractured but tight,discontinuous,vuggy.Contacts are irregular.Comprise 70 percent of rock. ROCK TYPE:DEPTH (FT.) 90 (82.8) REC (RQD) 98 (71 ) 100 (85) LE:NGTI-l OF RUN 1FT) Run 1C 53.2 to 58.3 Run 11 58.3 63!% OESCRIPTION :COLOR,TEXTURE,FOLIATION ,Jor NTI NG,FRACTURING,FAULTI NG, ALTERATION,WA.TER LOSS OR GAIN,CAVING,LOST CORE,CEMENT1NG,ETC. 54.3-61.2 Quartz stringers,spacing is very close to close,less than 0.1 in.wide,healed joints at 60 0 to 90 0 are quartz filled. Argill ite/ Graywacke ROCK TYPEDEPTH (FT.] 60 (55.2) 62.2 Bedding/foliation is at 20°. 63.5-67.7 Fracture zone,joint and fracture spacing is very close at 15°to 30 0 and 50°___ to 70 0 ,planar,smooth to rough.Quartz veins.Run 12 30 Bedding/foliaton is highly folded and stretched O~ Core loss of 1.5 feet.82(34) 68.8-69.2 quartz vein at 20°to 90°,highly fractured but tight,irregular,vuggy. 100 (92.1) Run 20\88 94.4 (53) to 97.8 R~~97.8 (8) to 101.5 100 (41) 86 (29) 98 (59) 57 (31 ) Run Z 105.0 to 109.1 Run 2 101.5 to 105.0 Run 25 112.5 to 117.6 Run 24 109.1 to 112.5 105.0 Bedding/foliation is at 10°to 20 0 • Argillite is "spotted"with a dark mineral less than 0.05 inch (possibly biotite). 105.7-106.7 Quartz vein,highly fractured, fractures at 40°and 70 0 ,vuggy,sulphide mineralization.Contacts are irregular at 00 to 10°. 108.5-175.0 Joint spacing is close to moderately close,joints are generally planar, smooth to rough iron oxide stained,few with carbonate or quartz filling. 110.3-113.9 Quartz stringers,close spacing, stretched,irregular,discontinuous,tight. 112.5-114.7 Core loss of 1.7 ft. 113.9-114.7 Quartz vein,highly fractured but tight,irregular,fractures at 30°,vuggy, minor iron oxide staining. 110 (101.3 82 (48) 94 (69) 100 (76 ) Run 17 80.7 to 84.0 Run 16 77.2 to 80.7 Run 14 68.9 to 72.3 77.2-105.0 No drilling water return. 80.1-108.5 Fracture zone,joint and "hairline'" fracture spacing is very close,0°to 20°and 60°to 90°,irregular and discontinuous, carbonate and iron oxide staining on most joints,silt on joints from 92.6 to 103.3, slickensides at 93.0 and 105.0 on joints at 00 to 15°and 80~ 70.7-72.0,72.3-72.6 Quartz veins,highly fractured but tight,vuggy,sulphide mineralization. 72.6-77.0 Quartz stringers,parallel to bedding/foliation at 0°,less than 0.5 in.Widr-:-~8I Contacts are tight.I R~~~572.3 (90) to 77 .2 80 (73.6) 70 (64,4) ~~j fj ~.-....1;.,,].'\1 -1 --]]c'-~J --].-]'.--"--]]_J --1 '']-----l ----]~--l 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P57oo.o5 CLIENT ALASKA POWER AUTHORITY JOB NO.P57oo.o5 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-l SHEET NO.5 OF 24 SITE Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO.6 OF 24 REe (RQD) 93 (81) 100 (100) 100 (73) LENGTH OF RUN (FT) ~~;t~1 (~~~) 153.2 Run 37 1 96 166.5 (96) to 171.5 Run 36 161.5 to 166.5 Run 34 153.Z to 1156 .2 IRun35 156.2 to 161.5 OESCAIPTI ON :COLOR,TEXTURE,FOUATlON,JOINTI NG,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,,LOST CORE,CEMENTING,ETC. 149.o-157.9 Argillite interbedded wlth medium gray,fine grained graywacke,beds 2 inches to 2 feet wide,beds are htghly folded, possible sheared along bedding planes, healed, ti9ht,hard. 158.5-158.7 Quartz vein,discontinuous, irregular,tight,0.5 inch wide. ROCK TYPE Argi 11 ite DEPTH (FT.J 170 (156.5 160 (147.3) 150 (138.1 ) REe (RQO) 100 (73) 92 (93) LENGTH OF RUN (FT.) Run 30 134.0 to 139.2 Run 26 117.6 to 120.9 DESCRIPTION:COLOR,TEXTURE,FOLiATION,JOJNTING,fRACTUAING,FAULTlNG , ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 133.2-134.0 Fracture zone,joint spacin9 very close,joints at 00 to 20 0,iron oxide staining,trace clay and carbonate,slight weathering on joints.Core loss 0.4 feet. ROCK TYPE Argillite/1117.6-118.6 Quartz vein,highly fractured but Graywacke tight,1.5 inch wide.Contacts at 00 to 10 0. DEPTH lfT.l 130 (119.7) 120.9 (1l1.3)1-1-"A"'rgncln lrTIT1"'te;;--lIMedium to dark gray,very fine grained,bedding un UnDO and poorly developed foliation are at 50 to 15~120.9 (53) very thinly laminated,sulphide mineralization.to Fresh,hard,well indurated.Joint spacing is close to moderately close,joints a~e generally 125.4 planar,smooth to rough,very few wlth carbonate or quartz filling. 120.9-124.5 Quartz stringers,spacing is very jRUn 281100 close to close,mostly at 50 c to 90 0,some at 125.4 (22) 00,less than 0.1 in.wide.to 120.9-129.0 Clay filling in joints.129.0 129.0-134.0 Healed fractures"quartz stringers Run 291100 ~rregular,discontinuous,tight,less than 0.1 129.0 (78) In.wlde.to 134.0 140 (128.9) 139.5 Bedding/foliation,20 0. 143.0 Sulphide minerals up to 0.5 inches becominq abundant.Progressive replacement with quartz. 144.3-148.0 Core loss 0.2 feet. 148.5 Bedding/foliation,lo~ Run 31 139.2 to 144.3 Run 32 144.3 to 148.0 98 (92) 95 (81) 180 (165.7 Run 3811UU 171.5 (92) 176!2 175.0-276.1 Joint spacin9 is generally moderately close,joints are generally planar, rough to sl ick,very few with iron oxide I 1 staining or quartz fillin9·Run 39 100 176.3 (100) to 181.4 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING AIEPORT CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-l SHEET NO.7 OF 24 SITE Devil Canyon (North Bank) HOLE ~lO.BH-l SHEET NO.8 OF 24 REC (ROD) LENGTH OF RUN (FT.! 'Run 47~ 214.9 I (87) to 220.0 DESCRIPTION:COLOR,TEX,TURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 216.3-217.7 Lithic graywacke,subangular to subrounded argillite and graywacke fragments, up to 1 inch. ROCK TYPEDEPTH (FT) I I Argill ite/I I Graywacke REG (RQD) LENGTH OF RUN {FT) 181.4 to 186.3 QESCRIPTION COLOR l TEXTURE,FOLlATION I JOINTING,FRACTURING,FAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 182.2-184.0 Bedding/foliation highly folded,~-W~I fractures are healed with quartz,tight,hard.I"un 1.100 (100) ROCK TYPE Argill ite DEPTH (FT) Run 41 100 186.3 (100) I r220to(202.5)191.5 Run 421100 191.5 (100) 196~a Run 491100 225.1 (100) to 230.0 Run 501100 230.0 (100) to 235.0 Run 51 82 235.0 (82) to 240.1 241.6-241.8 Fracture zone,joint spacing is Run 52 100 very close,joints at 0°to 10°,clay coating..(88) 241.8-249.0 Quartz stringers,spacing is very Run 53 98 close to close,some offset along bedding/241.8-(98) foliation,healed,tight.246.9 230.2 Quartz vein at 50°,tight,0.5 inch wide. 231.5-232.0 Quartz ~ein at 0°,1 inch wide. 232.7-235.3 Healed shear/fracture zone,joint spacing is very close,beds offset,brecciated, healed with quartz,ti9ht,hard,fractures irregular at approximately 70°to 90°. 235.0-240.1 Core loss of 0.9 feet. 227.0 Bedding/foliation is at 10°. 220.0-221.5 Fracture zone,joint spacing very close,at 0°.Core broken into fragments ko-Ru-n~4=8+--1 00 less than 1 inch,surfaces smooth and coated/220.0 (65) filled with grayish green clay.Core loss of to 0.6 feet.225.1 222.5-223.1 Quartz pods,parallel to and crosscutting bedding,irregular,discontinuous. 230 (211 .7 240 (220.9) Run 431100 196.5 (100) to 201.5 Run 441 100 201.5 (94) to 204.9 Run 45 "9b 204.9 (72)to 209.9dyRun46100 209.9-(84) 214.9 207.3-207.4 Quartz vein,folded,tight. 209.0-209.9 Fracture zone,open,very close spacing,fractures parallel bedding/foliation at approximately 10°,slickensides,iron oxidE staining,Core broken during drilling. 209.9-215.8 Fracture,joint spacin9 is very close to close,average 2 inches at 0°and 70° to 90°,irregular,tight,healed with quartz. Interbedded argillite and graywacke,Argillite is dark gray,very fine grained,very thin to thinly bedded,Graywacke is reddish gray, fine to medium grained,Bedding and poorlY developed foliation are at 0°to 30°. Generally fresh,hard,well indurated,Joint spacing is moderately close. 193.7-199.2 Quartz stringers and pods,closely~I ~ spaced,folded,parallel to and crosscutting bedding/foliation,tight,less than 0.5 in. wide. Argillite/ Graywacke 210 (193.3 200 (184.1 190 (174.9) 191.5 (176.3 ~ill TI ,~~~1 1 'J ~ j ,!j j "--~'-')~~--]-'1 ---'J )-_OJ -'-1 "-'--']-)---)""'J 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P57DO.05 CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO.9 OF 24 SITE Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO.10 OF 24 DEPTH (FT.)ROCK TYPE DESCRiPTION:COLOR,TElI:TUAE,FOLIATION.JOINTlNG,FRACTURlNG,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.) REe (ROD) DEPTH (FT.)ROCK TYPE OESCRIPT~:COLOR,TEXTURE,FOLIATION ,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOSTCORE t CEMENTING,ETC. LENGTH OF RUN (FT.) REe (RQO) 98 (43) IUU (100) 100 (93) 100 (67) Run 66 291.5 to 296.0 100 Run 641(57) Run 651 94 286.6 (71) to 291.5 Run 63 280.3 to 285.2 -9 tlb[un 6 (85)303.0- ~~---sT Run 7 .0+-- Run 71 98 306.1-(69) 311 .0 I Run 62 276.1 to 280.3 294.8-296.0 Chilled zone,very fine grained. Dark yellowish brown to dark green,fine grained feldspar laths,5%white,radiating zeolites up to 0.2 in.,flow structure at 3D'. Joint spacing is close,slickensides on most joints.Slightly weathered,hard. 276.1-277.0 Chilled zone,very fine grained. 276.1-296.0 Drilling water return 50%. 276.1-310.8 Joint spacing is close to very close,joints are generally planar,slick and open,iron oxide stainin9 on most joints,talc coating on few. Mafic Dike (Diabase?) 280 (257.71) 300 (276.2 290 (266.9) 296.0 i h(272.5)Graywacke I R'-e'd"d~is~h-g-r"-ay-C,"""'f"inc-e"'-g-r-al~·n-e'd',-m-a-'s""sTi-ve.Run~ Generally fresh,hard.296.0 I (28)I 296.0-300.4 Shear/fracture zone,joint to spacing is very close,joints at 40°to 60°298.9 and 20°,slickensides on many surfaces,talc/-R--68 chlorite coating,random,irregular fractures.2~~9 Core loss of 0.6 feet.I . 297.0-298.9 Core broken by drilling.303 t g 301.0 Bedding is at 50°.. 303.7-304.3 Healed fracture zone,fracture spacing very close,quartz filling,tight, hard. 305.0-308.5 Numerous healed joints and fractures,joints at 00 and 30°,fractures at 65 0 to 90°,talc/chlorite coating on many surfaces.Core broken by drilling,core loss of 0.6 feet. ]fun 6q 69 270.31 (54) to 274.2 Run 591 98 265.6 (94) to 270.3 Run 581 94262.5 (70) to 265.5 Run 57 260.6-1 I DO 262.5 (50) Run 551 100 251.5 (84) to 255.9 Run 541 98 246.9 (98) to 251.5 265.0-276.1 Quartz stringers at 40°to 70°, less than O.I inch wide,closely spaced. 265.8 Bedding/foliation is at 0°to 10°. 253.5 Bedding /foliation is at 30~ 254.1-277.3 Joint spacing is close,chlorite/ talc coating. 251.0-252.0 Joints at 10°and 30°,slickenside I I I Dark gray,very fine grained,very thinly laminated,massive.Fresh,hard,well indurate 274.2 Probable fracture zone,joint spacing very close,light green mineral coating.Core broken by dri II ing,core loss of 1.2 ft.I Run 61 100 I 276.1-276-3 Contact zonejbrecciated argillite.(26) fffglillte/ Graywacke 1246.0 Bedding/foliation is at 0°to 10°. 256.01rl 1235.6)Graywacke Reddish gray,fine to medium 9rain sand in Run 56 100 argillaceous matrix,bedding/developed foliatio 255.9 (100) is at 0°to 10°. Generally fresh,hard,well to indurated.260.5 259.0-262.5 Bedding/foliation intensely folded brecciated and healed with carbonate,tight, hard. 261.5-262.5 Fracture zone,joint spacing very close,0°to 40°,irregular to planar, discontinuous,talc coating. 260 239.3) 276.1 (254.21 lit i 250 (230.1) 270 (248.5 271.8 .J-~--c::-c~250.2)1 Argillite JOB NO,P5700.05 ACRES MIIERIC/.\N INCORPOR~.TED -CONSULTliIlG ENGINEERS BUFfllLO •NEW YORK DRILlHHJi !'iEPIH:IIT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-l SHEET NO,11 OF 24 PROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.8H-1 SHEET MO.12 OF 24 Run 72 94 311.0 (94)to 315.7 REG (ROD) 98 (92) 100 (100) 100 (89) LENGTH OF RUN {FT.l Run 80 349.7 to 355.0 Run 78 339.8 to 345.0 Drill ing water return 1ess than 50~_-----I--------j Run 79 345.0 to 349.7 OEseRI "11 Q!j :COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,fAULTI NG, ALTERATION,WATER LOSS OR GAl N,CAVI NG,LOST CORE,CEMENT'ING,ETC. 345.0-381.5 percent. ROCK TYPEDEPTH {FTJ 350 (322.2) I -I I==::c:-;-~I~~~~::~~::':=~--1~I--I Graywacke (Conglomerate) REG (RQD) 100 (95) 100 (92 ) LENGTH OF RUN (FT) Run 74 320.0 325?0 RUi173 315.7 to 320.0 DI':SCRIPTION :COLOR,TEXTU:-'f,FOLIATiON,JOINTING,FRACTURING,FAULT]NG, ALTERATION,WATER LOSS OR GAl N,cAVI NG,LOST CORE,CEMENTI NG 1 ETC 310.8-598.2 Joint spacing generally close to moderately close,generally planar,smooth, carbonate,chlorite and talc coating. ROCK TYPE Graywacke DEPTH (FT.) 310 (285.4 320 (294.6) -~-Run 77 98 334.7 (96) to 339.3 .[Uil81 I rmT356.1-360.7 Graywacke conglomerate lnter-100 calated with reddish gray,aphanitic igneous j355.0 ( ) rock containing subrounded to subangular to felsic fragment up to 0.5 inches,hard,contac s360 1 at 50·,tight.. 360.7 J ..I Run 82 100 (332.0)1 Felslc Dlke I Light to medium qray with reddish brown "M' (Rhvodacite)streaks,aphanltTc,hlgnly silicic,occasional Run 83 100 plagioclase and quartz phenocrysts,inclusions 361.3-(100) of argillite and graywacke,flow structures at f--3C-63__._4-+_~,=-__ 50°.Fresh,very hard,tight contacts.Joint R 84 100 spacing close,are planar,smooth to rough.un i~ Run 85 100 364.4 (100) to 369.3 330 (303.8) 331.2 11304.9) 340 (313.0) Graywacke (Conglomerate) 324.0-326.0 Healed breccia,fracture spacing is very close,quartz filling,tight,hard. 329.7-334.7 Core loss of 0.4 feet. 331.2 Sharp contact~._ Reddish,medium to dark gray,fine grained argillaceous matrix with 50 percent to 60 percent angular to subrounded rock fragments of sedimentary,volcanic and plutonic origin, fragments 0.01 ft.to 0.3 ft.)no foliation, massive,very thin interbeds of argillite. Fresh,hard.Joint spacing moderately close, chlorite/talc and carbonate coating. Run 75 325.0 to 329.7 Run 76 329.7 to 334.7 100 (68) 92 (92) 3702 i-----------=::--r I Run 86340:8)I Ir~~~~ywacke OC descnptlOn,as above.369.3 (Conglomerate)to 373.6 100 (77) ]~j ~~~..~~.'~"'I ]11 j :~":J :~ ]~~l -_oJ ~~~)---~--)~-~-l ..-._--]-----]~~]-~-])~~]-'~1 -)~-,--) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SITE Sus i tna Hydroe 1ectri c Proj ect . Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO.13 OF 24 PROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO.14 OF 24 Graywacke 1373.4-373.5 Joint at 70°to 80°,clay filling (Conglomerate)and rock fragments. Run 90 I 94 386.5 (86) to 391.4 DESCRIPTI ON ~COLOR,TEXTURE,FOllATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION.WATER LOSS OR GAIN,CAVING"LOST CORE,CEMENTING,ETC. 413.4-413.8 Core badly broken,angular fragments up to 0.15 ft.Joint at 15°, slickensides,chlorite coating. LENGTH REe OF RUN (RQD)1FT) Run 94 88 406.6 (88) to 411.5 Run 95 97 411.5 (47) to 415.3 Run 96 96 415.3 (62) to 420.3 Run 971 84 420.3 (76) to 424.1 ---' Run98 98 424.1 (98) to 429.3 Core loss of 1.5 feet.408.1-424.1 ROCK TYPE Graywacke (Conglomerate) DEPTH (FTJ 420 (386.6)1 410 (377 .4) REC (RQD) 96 (67) 100 (100) 100 (100) 100 (94) Run 9"1 391.4 to 396.5 LE:NGTH OF RUN (FT) Run 89 381.5 to 386.5 Run 88 378.8 to 381.5 Run 87 373.6 to 378.8 DESCRIPTION:COLOR I TEXTURE:.FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 386.5-391.4 Core loss of 0.3 feet. 381.5-401.5 Core broken by drilling,joint spacing is moderately close,joints healed. ROCK TYPED!::Pil-l (FTJ 390 359.0) 380 (349.8 Run 931 100 401.5 (100) to 406.6 400 (368.2)401.0-405.7 Healed fractures at 30°,spacing is very close to close,discontinuous, carbonate filling. Run 92 396.5 to 401.5 100 (66)430 i I I Run 991 100(395.8)429.3 (100) to 434.3 Run 100 98 434.3-(88) 439.4 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ..--~ ACRES AMERICAN INCORPORATED -COIllSULTiNG ENGINEERS BUffALO,NEW VORK DRilliNG REPCH1V CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-1 PROJECT Susitna Hydroelectric Project HOLE NO.BH-1 SITE Devil Canyon (North Bank)SHEET NO.15 OF 24 SITE Devil Canyon (North Bank)SHEET NO.16 OF 24 DEPTH (FT.)ROCK TYPE DE:SCRIPTION ;COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTING.ETC LENGTH OF RUN (FT.) REG (RQD) DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TEX-rURE,FOLIATION,JOINTING,FRACTURING.FAULTI NG, ALTERATION,WATER LOSS DR GAIN,CAVI NG,LOST CORE,CEMENTI NG,ETC. LENGTH OF RUN (FT) REG (RQD) 440 405.0) Graywacke (Conglomerate) un 101 1 roo 439.4 (100) to 44.4 470 1 Graywacke (432.6)1 (Conglomerate) by drirTTng.TaTe/chlorite,quartz,carbonate and white mica coatin9.Core loss of 1 .0 ft. un 107 468.6 to 473.1 un llffi 473.1- 475.3 IW (100) 87 (81 ) Run 101\100 444.4 1(100) to 449.5 450 (414.2 Run 10 449.5 to 454.7 100 (96) 480 441.8) un 109 475.3 to 480.4 Run 11 0 480.4 to 485.4 100 (100) 100 (100) 460 (423.4) 454.7-514.8 Drilling water return 50%. 468.6-497.0 Fracture and joint spacing is very close to close averaging 2 in.,fractures and joints at 0°to 90°but mostly 30°, discontinuous,irregular,tight but some broke Run lot 100 454.7 (100) to 459.8 f----+-----1 Run 10 100 459.8 (95) to 463.8 Run lOp 100 463.8 1 (100) to 468.6 490 (451.0 500 :(460.3) 497.0-500.0 Fracture and joint spacing general1y close with zones of very clos~ discontinuous,tight.Talc,carbonate and minor quartz and white mica fi11in9· Run 1111 100 485.4 (94) to 488.7 b--n-~488.7 (63) to 491.5 ~491.5 (79) to 496.7 ~14rlOO 496.7 ci (96) to 501.4 ~,,1 ~'I 0 ~11 ~.,.>'I ~~\ \1 J ':i :I ]:1 )J "]'""""]"""")""-1 -"""~1 -ooJ ---1 ~o""--1 "~l ~)~-l --1 "~1 "'--1 "0 -1 --"1 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO,BH-1 SITE Devil Canyon (North Bank)SHEET NO.17 OF24 DEPTH OESCAIF'TI ON:COLOR,TEXTURE,fOLIATION l"OINTING,FRACTURING,FAULTI NG,LENGTH REC ROCK TYPE OF RUN (FTJ ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC.(FT)(RQO) ~raywacKe (Conglomerate)un 115 100 501.4 (100) to 506.5 un 116 100506.5 to (100) 511.5 510 (469.5) un 117 511 .5 100 to (94) 514.8 un 118 100 514.8 (100) to 519.9 520 Run 119 98478.7)519.9 (98) to 525.1 un 120 100 525.1 (94) to 530.4 530 530.4-539.0 Core loss of 0.5 feet. 487.9)Run 121 86530.4-(87) 534.0 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-l SITE Devil Canyon (North Bank)SHEET NO.18 OF 24 DEPTH DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG,LENGTH REC ROCK TYPE DF RUN IFTI ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC.(FT.)(ROO) Graywacke (Conglomerate) Run 122 100 534.0 (100) to 539.0 Run 123 100540539.0 ('00)497;1)to 544.3 543.5 Joint at 35°,planar,slickensides on talc. '... Run 124 98 544.3 (96) to 549.2 550 Run 125 100 (506.3)549.2 (100) to 554.5 Run 126 98 554.5 (92) to 559.7 560 Run 127 100 (515.5)559.7 (100) Quartz vein 0.1 feet wide.to563.4 564.8564.3 Joint at 55°,planar,slickensides on chlorite/talc. ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO 1 NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-1 PROJECT Susitna Hydroelectric Project HOLE NO.BH-l SITE Devil'Canyon (North Bank)SHEET NO.19 OF 24 SITE Devil Canyon (North Bank)SKEET NO.20 OF 24 DEPTH (FT.) 570 524.7) ROCK TYPE Graywac ke .(Cong 1omerate) DESCRIPTION:COLOR,TEXTURE,rOLlATION ,JOI NTING,FRACTURING,FAUl.TI NG I ALTERATION,WATER LOSS OR GAl N,CAVI NG,LOST CORE,CEMENTI NG,ETC. 574.0-582.0 Lithic fragments increase to cobble size,up to 6 inches. LENGT!" OF RUN 1FT.) un 128 564.8 to 569.9 un 129 569.9 to 575.1 REC (ROO) 100 (96) 100 (96) DEPTH [FTJ 600 552.3) ROCK TYPE Graywacke Conglomerate) mCRIPTION COLO R,TEXTURE,FOLIATION ,JOINT1NG,FRACTURING,FAU LTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 598.2-602.2 Healed fracture zone joint spacing very close,joints at O·to 10·irregular, rough,carbonate healed,joints at 70°to 90· irregular,rough,carbonate healed,talc/ chlorite filling.Most joints tight but some broken by drilling. 598.2-637.7 Joint spacing is generally close, planar,smooth,ti9ht,coated with talc/ chlorite and carbonate. LENGTH REGOFRUN {FT.}(ROD) un 134 98 595.1 (89) to 599.5 ~o599.5 (79) to 604.2 un 1361100 604.2 (100) to 609.1 run 1301100 575.1 (85) to 579.9 ~""13'I 100 579.9 (100) to 584.9 ~137 93 un 138 100 610.5 (100) to 614.8 l"~1391'00614.8 (96) to 619.8 580 I(533.9) 590 (543.1) 577.8-578.9 Joints at 40°to 50°,spacing is very close,joints healed,chlorite/talc coating,some slickensides.Core broken .by drilling,angular pieces. 579.9-645.2 Drilling water return less than 50%. Run 132 584.9 to 590.1 Run T33 590.1 to 595.1 100 (100) 100 (96) 610 561.5) 620 (570.7) 612.4-613.3 Quartz vein,highly fractured, tight,irregular,inclusions of argillite. 614.9-620.5 Fracture zone,joint spacing is very close,joints at 30°,healed with talc/ chlorite,tight but some broken by drilling. 615.0-630.0 Lithic fragments up to 0.7 feet. 623.8 Increasing amounts of very thin to thin beds of argillite. Run 140 619.8- 621.7 Run 141 621.7 to 626.8 ImJ (84) 98 (98) l!-~~~f:j ~~]1 ~]~.~1l jl ~}J.,:1 ~I J ;1 j! I ..J !' --),---1 1 ]---1 __-~J -]J ].-1 -1 ----1 1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO t NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.BH-l SHEET NO.21 OF 24 PROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.BH·1 SHEET NO.22 OF 24 Graywacke 630 i (Conglomerate) (579.9) 96 (92) 100 (100) un l~g-g--675.0 (62) to 680.5 un 153 85 80.5 (24) 0 683.9 un ~I 85683.9 (60) to 690.0 un l5-51 100 690.0-(87) 695.2 Run 15 670.8 to 675.8 Run 15 665.6 to 670.8 LENGTH REC OF RUN 1FT)(ROD) Run 14 90 660.4 (90) to 665.6 DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC 689.8 Joint at 00 ,planar,slickensides on chlorite. 690.1-693.0 Fracture zone,joint spacing is very close,joints at 30 0 to 40 0 ,planar, smooth,healed with carbonate and chlorite, some broken by drilling. 678.9-683.8 Shear/fracture zone,fracture and joint spacing very close,joints at 70°,planar smooth,fractures irregular,rough.Carbonate and talc/chlorite coating on most surfaces, slickensides on some joints. 678.9-690.0 Core 105s of 0.2 feet. ROCK T'l'PE Graywacke (Conglomerate) DEPTH (Fl) 680 625.9) 670 616.7) 690 (635.1) TOU (100) 100 (100) LENIHH RECOFRUN (FT)(RQD] Run 14 (100)626.8 to 631.7 Run 14~100 631.7 (100) to 636.7 Run 1481 100 655.2 (87) to 660.4 Run ;,(100 641.4 (100) to 645.1 Run 146 00 645.1 (82) to 650.0 Run 147 650.0 to 655.2 DESCRIPTION:COLOR,TEXTURE,FOLIATION I JOINTI NG,fRACTURING,fAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 655.2-660.9 No drilling water return. 649.3-649.8 Core broken by drilling. 637.7-721.3 Joint spacing is close to mOderatemclose,joints generally planar,smooth,coated Run 14 J I with carbonate,chlorite and talc.636.7 ~ 641.4 630.0 Joint at 20°,0.04 inch of calcareous clay. 632.0-634.0 Joint spacing is very close, at 30°,discontinuous,tight. ROCK T'l'PEDEPTH (FT.) 640 589.1 ) 660 (607.5) 650 (598.3) JOB NO. ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ALASKA POWER AUTHORITY P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO 23 OF 24 PROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.BH-1 SHEET NO.24 OF 24 DEPTH (FT.)ROCK TYPE DESCRIPTiON:COLOR,TEXTURE,FOLIATION ,JOINTI NG,FRACTURING,FAuLTI NG, ALTERATION,WATE:A LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. LENGTH OF RUN (FT.) REC (ROD) DEPTH (FT.)ROCK TYPE OESeR I PTIQN :COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI 11IO, ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTING,ETC. LENGTH OF RUN {FT.l REO (RQol 100 (78) 700 (644.4) Graywacke (Conglomerate) Run 15 695.2 to 700.5 Run 15 700.5 to 705.6 98 (98) 98 (98) 730 (672.0) Graywacke (Conglomerate)un 162 727.1 Joint 0.1 inch wide with clay filling an ;~i'~- rock fragments.Run'16 95'-----+ 727.4 (77) to 731.8 731.4-732.1 Fracture zone,joint spacing very close,joints coated with carbonate and talc.~~694--- Core loss of 0.6 feet.un 733.0 Joint with clay filling.731.8 (77) to 737.1 707.0-708.3 Shear/fracture zone,joint spacing very close,joints at 30°to 50 0 ,chlorite and sulphide mineralization,slickensides on one joint. Run 15 705.6 to 71 O.6 100 (100) 740 (681.2) 737.6 Joint at 60 0 ,0.1 inch wide,carbonate and clay filling.un 165 737.1 to 741.5 93 (80) t---~-Run 15 100 710.6 (100) to 715.7 Run 16 1100741.5 (100) to 745.7 ,ooened bv dri 11 i no .1--- Run 16193 745.7 (73) to 750.2 END OF 80RING 745.4-748.0 Fracture zone,joint spacing very close,joints at 50 0 ,planar,smooth;healed with carbonate,tight,sam,, 745.7-750.2 Core loss of 0.3 feet. 750.2i-I I I (690.6)I 98 (98) Run 16 715.7 to 721.0 710 653.6) 100 (91 ) to very close,[---I I tight,~un 161 721.0 to 725.5 721.3-750.2 Joint spacing close joints generally planar,smooth, coated with carbonate and talc. 720 662.8) ~~),-~l :1 ~~J ~~ tJ ,j :I ~j }'-]~]-]]~]-1 -]J <-1 1 1 Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG SUMMARY LOG REMARKS Fracture zone, healed. liil Joint,slickensides Joint,slickensides Shear/fracture zone Fractu re zone, healed. Fracture zone, healed. J Fracture zone, heal ed. Job No.P5700.05 Hole No._-"B"'H"--l'--_ Sheet No._2_of ~ ROCK TYPE Felsic Dike Graywacke Graywacke ALASKA POWER AUTHORITY Susitna Hydroelectric Project Devil Canvon (North Bank) Client Project Site DEPTH (FT.) 520 380 420 560 500 480 360 400 640 440 460 600 620 580 ,540 I •I I I 1 1-1 REMARl<S • Quartz stringers. Quartz stringers. TOP OF ROCK 11.8' IFracture zone. l Quartz vein. Fracture zone, healed with quartz. ~Shear fracture, healed. Quartz stringers. l Quartz stringers. J Shear/fracture zone, -Fracture zone, healed. -Breccia,healed. Job No.__P5700.05 Hole No.BH-"_l~_ Sheet No._1_of _3_ ArglTTlfe7-~I Quartz stringers. Graywacke ROCK TYPE Overburden I I I I Argillite ROD % CORE RECOVERY % Client ALASKA POWERJ:A",U-"TH""O'l'R~IT,-Y,--_ Project Susitna Hydroe 1ectri c Proj ect Site __"~il Canvon (North Bank) DEPTH I ELEV. (FT.) (FT.) a 20 40 60 88 100 120 140 160 180 - 200 220 240 260 280 300 320 340 Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Client~1 ASKA POWER AIITHORITY Job No._P57QlLJ1!L.__ Project Susitna Hydroelectric Project ..__Hole No._B_.H'---'l _ Site Devil Canvon (North Bank)Sheet No._3_of _3__ PERMEABILITY CORE RECOVERY RaD NUMBER OFD{~T~~~~~\(K)cm/,e~%%JOINI6SFTPER ROCK TYPE REMARKS 1-_1---,'0.6 lOA 10-2 204060 eo 204060 eo 5 ":;'O;"';';"'--'i"O'+~__=_-1--1 'Graywacke 1-----..-f- 720 f--')~\1~¥:l 740 --lP--f- e---723 b Fracture zone. 760 WII j-f-END 7~6.~9RING~f-::-•--~j _._---f----_'=-~._~~f---f-~i _ -1 I e--I I I '-I- i -+--I_t--~-_.--j f I f----1.-----I '--I'_._.-1---~ -.il ._-_.I 1-_.-.-- c--rr -l'- =-j ['L---_1-·- ----I ----_.- ---,--- ----+-+,-+--1-++1 +-H--+-+t-f--f-+-+-+-+++-+-l ----+--++-+-++H--l-+-i--i-+--1--f--++-+--1-+-t-f--f .-1 ---I - ---1-.-1-+-+-1-++-+-f-+-+-H -f-j -1--+-+-+-+-+-+-+-1 _-+--1-1 +-+-+-+-+-H--+--f --.----- --- _.--.- f----+--+H++-++t-i -+-+-+-+--t--+. iU 2 .,~l 'I J ,".~'H J ~'i ")'1 ."~')")]~-J ="~]],.)"~)"<]<~'1 ~] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT:ALASKA POWER AUTHORITY J08 NO.:P5700.05 PROJECT:Susitna Hydroelectric Project HOLE NO.:BH-2 SITE:Devil Canyon (North Bank)SHEET NO.1 OF 21 CONTRACrpR:The Drilling Company DRILLING DATES"Sept.10 TO Sept.15,1980 LOGGED 8L K.J.white,M.P.Bruen DATE:July 1981 REG (RQO] 98 (82) 100 (90) LENGTH OF RUN (FT) Run 7 21.0 to 26.0 Run 8 10026.0- 28.0 (57) Run 9 94 28.0 (82) to 33.0 Run 10 33.0 to 38.0 SHEET NO,2 OF 21 HOLE NO.BH-2 J08 NO.P5700.05 DESCRIPTION;COLOR,TEXTURE,FOUATIQN,JOINTI NG,FRACTURING,FAULTI NG I ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 28.4-32.2 Numerous healed fractures,very closely spaced,healed with quartz,irregular and discontinuous.Core loss of 8.3 feet. 30.3,30.9 Two healed shears,30 and 50 0 , 1 in.wide,quartz healed breccia,tight, 30.4-90.9 Joints close to moderately closely spaced,planar,rough to smooth,iron oxide staining,some with quartz filling. 3B.0-67.0 Orilling water return 50%. ROCK TYPE Oevil Canyon (North Bank) Argi 11 ite Argi 11 itel Graywacke SITE PROJECT Susitna Hydroelectric Project CLIENT ALASKA POVIER AUTHORITY DEPTH (FT.) 30 (26.0) 40 (34.6) 50 (43.3) 46 .0 -1 -------+ (39.8) % REC (RQO) 64 (48) 100 (89) Run 6 16.0 to 21.0 Run 5 10.5 to 16.0 CASING DIAMETER:NW (3.0")I.D. CORE DIAMETER:NQ (1.75")0.0. 21.0/-Core loss of 0.1 feet. Oark brown,organic silt with trace of light gray ash,some angular cobbles.No samples taken.TOP OF ROCK Oark gray,very fine grained metasedimentary rock.Very thin to thin bedding coincident with weakly developed foliation at 35 0 to 65 0 • Zones of phyllitic sheen,poor cleavage,very thin beds of fine qrained graywacke. Ge~erally fresh,h~rd,well indurated, sulphide mineralization. Reddish dark graY~lne ~rained metasediment- ary rock.Bedding coincldent with weakly IRun 1 developed foliation at 40 0 •Very thin to thin 2.0 gO beds of dark gray argillite.Generally fresh ~o I (75) to slightly weathered,hard,well indurated,.0 sulphide mineralization (5%of rock). 2.0-30.4 -Joints closely spaced,planar,Run 2 50 (0) rough to smooth,iron oxide staining,few with 4 ( ) quartz filling.Run 3 6 0 6.0-13.0 -Fracture zone,joints and fractures Run 4 very closely spaced,irregular,discontinuous,8.1 63 healed with quartz,tight.Core loss of 4.4 Il~O~(0) feet. DE:~~~PR~~~~~~~~=RT~~S~u;:,~~~I~~V~N~~I~~'~;{a:C.Tci~~~~~:~~T~~~I LE~~~H Casing Advancer Diamond Core -Triple Tube N3,223,137. E616,101 00 60 0 LATITUDE DEPARTURE AZIMUTH DIP SOIL ROCK ROCK TYPE ELEVATIONS:DATUM MSL,A.S.P.C.,Zone 4 GROUND SURFACE 1213.4 ROCK SURFACE 1211 .7 80TTOM OF HOLE 645.z WATER TA8LE 1208.4 Depths measured along hole.True depths in (). All angles measured to the core axis. Overburden Argill ite Graywacke OEPTH (FT) NOTES:1) 2) DRILLING METHOD: LOCATION: 20 (17.3) 10 (8.7) 11.2 (9.7) 0.0 2.0 (1.7) APPROVED:.c'!,{}!!Cf/I.DATE:February 1,1982 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POI,ER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric ProjectPROJECT SITE Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.BH-2 SHEET No.3 OF 21 SITE Devil Canyon (North Bank) HOLE NO.BH-2 SHEET NO.4 OF 21 DEPTH (fT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FQLlATION)JOINTI NG,FRACTURING,FAUl.TI NO, ALTERATION,WATER LOSS OR"GAIN,CAVI NG,LOST CORE,CEMENTI NG,ETC LENGTH OF RUN (F"l\ REC (RQD) DE.:f'TH (FT.l ROCK TYPE DESCRIPTION:COLOR,TEX~URE,FOLIATiON,JOINTI NG,FRACTURING,FAULTI NG > ALTERATION I WATER LOSS OR GAIN 1 CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT) REC (RQD) Run 141100 51.9 (loa) to 56.0 End of intense iron oxide staining on I 56.9 I I joint surfaces.I--------l----- Run 161 90 62.2 (90) to 67.0 Run 17 98 67.0 (98) to 71.9 Run 18 100 71.9 (loa) to 76.8 Run 19 100 76.8 (84) to 81.8 Run 20 100 81.8 (91) to 86.9 Run 241 97 101.7 (76) 104.9 Core loss of 0.1 feet.I to 105.0 105.7-107.9 Core loss of 0.3 feet.I Run 251 90 105.0 (66) IOt?9 Run 26 100 56 109.5-112.0 Core loss of 1.5 feet due to core I Run 27 40 barrel mislatch during drilling.Core badly 109.5-(14) broken.112.0 Run 231100 96.9 (l00) to 101.7 96 (96) 100 (58) Run 29 1114.6- 119.fl Run 20 Run 211 96 86.9 (70) to 91.6 Run 221100 91.6 (91) to 96.9 Run 28 112.0 114?6 87.3-87.9 Core loss of 0.2 feet. Argi 11 ite/ Graywacke 114.6-119.4 Core loss of 0.2 feet. 100 (86.6) 110 (95.3) 90 89.4-90.9 Felsic dike,as aBove,subparallel (77.9)to bedding/fQliation,40 -70 ,somewhat (~£.~)Graywacke Reddish,dark gray,fine to medium grained I .metasedimentary rock with an argillaceous matrix.Bedding coi2cidentowith weakly devel- oped foliation at 30 to 40.Generally fresh, hard,well indurated. 90.9-138.6 Joints generally closely spaced, planar,smooth to rough,carbonate and quartz filling,very few with iron oxide staining. 100 (94) Run 15 56.9 to 62.2 58.6-61.2 Fracture zone,00 ,very closely spaced fractures,healed with quartz,up to 1 inch wide. 76,1-78.7 Felsic dike,light gray,aphanitic to fi ne gra i ned groundmas s,50%qua rtz and plagioclase phenocrysts,medium grained,less than 5%mafics,granodiorite (?)composition oContactsparalleltobedding/foliation at 60 tight.Chilled zone in dike up to 1 inch wide. Baked zone in surrounding argillite up to 6 inches wide. 78.7 Argill ite/graywacke,as above,but com- plexly folded and stretched,possibly brecciated,healed,tight. 63.65 Core loss of 0.5 feet. 64.4 Quartz vein,less than 0.1 inch wide, st/letched,parallel to bedding/fol~ation at 40 ,crosscut by quartz vein at 90 which is offset along foliation planes. 64.4-67.4 Quartz stringers,less than 0.24 inch,closely spaced,parallel to and cross- cutting foliation. 68.95-69.05 Core loss of 0.1 foot. Argillite/ Graywacke 60 (52.0) 70 (60.6) 8.0 (69.3) '1 1 Ji m ll:\]~~~,i\ } e]"~1 :__C]-]eel ~),)-)-'-]].'J -1 J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-2 PROJECT Susitna Hydroelectric Project HOLE NO.BH-2 SITE Devil Canyon (North Bank)SHEET NO.5 OF 21 SITE Devil Canyon (North Bank)SHEET NO.6 OF 21 Run 311100 123.2 (59) to 125.9 DEPTH (FT) 120 {103.9 130 (112.6 ROCK TYPE Graywacke DESCRIPTION:COLOR,TEXTURE,fOLIATiON,JOINTING l FRACTURING,fAU LTI NG, ALTERATiON,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTlNG.ETC. 119.4-119.8 Quartz veins,folded,stretched, brecciated,healed,tight.0 120.5 Bedding/foliation,50 121.7-123.2 Core badly broken,angular pieces less than 1 inch,some clay coating on joints at 0°. 125.9-132.0 Core loss of 2.5 ft.due to core barrel mislatch during drilling. LENGTH OF RUN 1FT) Run 29 Run 30 119.4 to 123.2 Run 32 125.9 to 132.0 REe (ROD] 92 (53) 59 (0) DEPTH I O~CRIPTI ON:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG,LENGTH REC ROCK TYPE OF RUN(FT.l ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTlNG,ETC.(FTl (RQD) 150 1Mafic Dike 147.5-155.0 Core loss of 0.7 feet.Run 39 89 {129.9 (Diabase)147.5 (89) to 152.2-155.0 Shear/fsacture 3one,joints very 1Sl,.Q closely spaced at 10 and 90 ,friable,Run 401 93 breccia and clay gouge,slickensides.Core 152.0 (0) badly broken.to 155.0 Run 411 100 156.4-172.9 Slickensides on many joint sur-155.0 (82) faces,some on quartz and chlorite fillings.to 160.0 160 j 160.0-165.4 Core loss of 0.2 feet.Run 42]96(13:3.6 160.0 (80) to 165.4 Run 431100 165.4 (100) to 170.5 -- Run 441100 170.5 (96) to 175.6 Run 45 100 175.6 (87) to 178.6 Run 46 1 100178.6-(47) 181.8 174.6-183.1 Chilled zone: 174.6-178.5 Fine grained,less than 5% zeo 1ites. 178.5-183.1 Very fine grained to aphani- tic near contact. 179.0-183.8 oFracbure zonO'joints very closel spaced at 20 ,40 and 60 ,chlorite,clay and slickensides on many surfaces.Core broken into angular pieces below 181.0. 170 (147.2 180 (l55.9 100 (73) 100 (74) 95 (85) 88 (30) Run 33 132.0 to 135.0 Run 34 135.0- 137.0 Run 35 137.0 tq to 140.3 135.0-135.5 Quartz stringers,up to 0.5 inch wide,irregular,discontinuous.Healed sheared contact between argillite and graywacke beds. 136.7-140.3 Core badly broken by drilling. Core loss of 0.5 feet. 137.8 Mafic dike,30 0 ,0.5 inch wide,tight contacts. 138.6-141.8 Shear6fractuse zone,joints very closely spaced,10 to 20 . 138.6-139.0 Joints generally close to very clos~ly spaced,planar,smooth to cQugh openpartlallyopen,many wlth sllckensldes. Dark green,fine to medium grained,feldspar Run 36' 1aths form a fi brous texture,5-10%white,140 3 radiating zeolite crystals up to 0.02 inch,t~ quartz replacement 8f crystals.Upper contact 143 4 at approximately 50 ,irregular,tight,argil-. lite unaltered.Kun s/100 Joints closely spaced,slickensides,chlorite 143.4-(65) on most.145.4 139.5-147.0 Chilled zone in dike:Run 38 100 139.5-139.8 Aphanitic.145.4-(100) 139.8-147.0 Very fine grained.147.5 141.3-144.0 Joints at 10 0 to 200, surfaces with chlorite and slickensides. 139.5 {120.81 Mafic Dike (Diabase) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POvlER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE No.BH-2 SHEET NO.7 OF 21 SITE Devil Canyon (North Bank) HOLE NO.BH-2 SHEET NO.8 OF 21 DE:F'Tll (FT.1 ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATIQN,JOI NTI MG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAY lNG,LOST CQRE,CEMENTI NG,ETC. LENGTH I REC OF RUN (RQD)(FT.) DEPTH (FT.)ROCK TYPE DESCRIPTION;COLOR,TEXTURE,FOLIATION 1 JOINTI NG,FRACTURING,FAULTI NG, ALTERATION.WATER LOsS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT) REC (RQD) Run 541 100 211.7 (94) to 216.9 Run 551100 216.9 (95) to 220.7 Run 561100 220.7 (96) to 226.0 Run 571100 226.0 (100) to 231.2 I-----~---jRun58100 231.2 (l00) to 236.3 213.4-213.7 Core broken along healed joints. 218.1-218.3 Fractu&e zone,healed,as above, but fractures at 90 . 230.0-231.0 Composition nearly quartzite,les than 20%fines in matrix. 231.2 Joint,30°,slickensides. 233.0 Bedding/foliation at 40 0 . Graywacke 220 (190.5 230 (199.2 100 (100) Run 49\100 190.8 (l00) to 193.8 Run 511 100 198.9 (100) to 203.2 Run 501100 193.8 (100) to 198.9 192.2~193.5 Limy sandstone,light 9ray,fine grained.Fresh,hard,well indurated.Gra- dational contacts. 192.5 Bedding and poorly developed foliation at 40 0 193.0-251.1 Joints generally close to moder- ately closely spaced,planar smooth to rough, tight,quartz and carbonate filling,no staining. Mafic Dike (Diabase)Run 471100 183.1J I 181.8 (73) (158.6J Graywacke Rock description,as above.to 183.1 Contact at approximately 30 0 ,irregular,185 9 tight,no shearing,no hornfels in graywacke.. 186.3-192.2 Quartz otringe&s,very close to ~R---4-8~-----i clnsely spaced at 20 to 70 ,0.04 to O.~inch un wide,crosscutting bedding/foliation (50 ),185.9 minor carbonate.to 187.7-187.8 Shear,50 0 ,breccia and clay in-190.8 completely healed with carbonate and quartz, moderately soft and friable.190 (164.5 200 (173.2 210 (181.9 Run 521100 203.2 (l00) to 206.5-212.2 Fracture zone~fractures very 1208.4 closely spaced at 00 to 20 •irregular,healed with quartz and carbonate,tight,hard. Run 531 100 208.4 (l00) to 211.7 240 (207.8 235.0-238.3 Interbedded argillite,very thin to thin beds,dark gray. 236.0-236.6~Shears,50°,healed quartz veins faulted 237.8-238.3 and folded comprising 40%to 50%of rock,less than 0.5 in.wide,tight,hard,well indurated, tight contacts. 241.0-242.0 Fractu&e zone,joints very close spaced at 50 0 and 0 ,open and tight, slickensides,pyrite,chlorite. 241.0-244.0 Interbedded argillite,very thin to thin beds,dark gray. Run 591100 236.3 (100) to 241.0 Run 601100 241.0 (89) to 244.7 ~m ~'l 'l 1i 1.~~1 ~J ~~"d j .1 ~J ~J --'"]_--__)<e'l -~-]]-1 )-~-'~l -']).J -]~l ~--)~--J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHOR ITY PROJECT Susitna Hydroelectric Project CLIENT ALASKA pm~ER AUTHORITY PROJECT Susitna Hydroelectric Project SHEET No.10 OF 21 HOLE NO.BH-2 JOB NO.P5700.05 Devil Canyon (North Bank)SITE JOB NO.P5700.05 HOLE NO.BH-2 SHEET NO.9 OF 21DevilCanyon(North Bank)SITE DEPTH (FT.)ROCK TYPE OESCRIPTI ON :GOLOR,TEXTURE,FOLIATION I JOINTING,FRACTURING,fAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTING I ETC LENGTH OF RUN 1Ft) REC [RQD) DEPTH (FT.J ROCK TYPE OESCAIPTI ON :COLOR,TEXTURE,FOLiATlON,JOINTING,FRACTURING,FAULT!NG, ALTERATION.WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT) REC (RQD) Run 691 100 277 .5 (48) to 281.5 Run 701100 281.5 (95) to 287.0 250 (216.5 Graywacke 245.8-246.0 Two joints,600-with slickensides.1 Run 61 244.7 to 249.8 Run 62 249.8 to 255.0 100 (90) 100 (l00) 280 (242.5 Argill ite 277.4-279.8 Shear/fracture zose,j8ints vesy closely to closely spaced at 0 ,20 and 50 , carbonate,chlorite and talc on most surfaceo' clay and slickensides on joints at 00 and 20 . 279.5-281.4 Bedding/foliation folded and stretched.Numerous quartz veins up to 2 in. wide,mostly along foliation and joints,tight,~I I hard. 279.5-287.0 Shear/6ractureozone,joints very closely spaced at 0 and 10 to 200,planar, smooth,tight,slickensides,talc coating, pyrite partially to completely replaced by quartz. Run 711100287.0 (96) to 292.0 Run 721 100 292.0 (100) to 297.0 Run 731 100 297.0 (87) to 301.7 Rock 8escrip~ion,as above.Bedding/foliation at 30 to 40 ,folded,stretched,offsets in bedding,argillite spotted with dark gray crystals 0.1 inches wide. 291.1,294.8 Two joints,70 0 and 60 0 respectively,trace clay. 297.0-304.0 Pyrite cubes up to 0.5 inches, partially replaced by qusrtz. 297.9 Quartz vein at 50 ,0.5 inches wide, slightly folded,PSrallel to bedding/foliation. 299.7 Joint at 50 ,clay filling and sand size argillite fragments. 293.6-294.0 Fracture zone,fractures very closely spaced,irregular and discontinuous, quartz healed,generally crosscutting foliation,tight. 287.0 I I I I I (248.5]Argillite/ Graywacke 290 (251.1 300 (259.8 Run 651 94 262.5 (83) to 267.3 lW11ll6l 100 267.3-1 (82) 269.5 Joints closely to moderately closely spaced, planar to irregular,slick to rough,tight to open,carbonate,chlorite and clay filling. Interbedded argillite and graywacke,metasedi- mentary rock.Very thin beds (less than 1 isc~----+-----~ wide)coincident with foliation at 40 0 to 50 ,100 zones highly folded and stretched.Tight,(7ft) hard.Sharp contact. Argillite/ Graywacke 2,8.51 Ro" 63 1 98(223.9 (255.0 (94) 260 to (225.2 (260.0 270 (233.8 Run 671100 269.5 (73) to 274.7 300.5-300.7?Shear,healed,folded and breciatel Run 741100 302.0-302.1)fragments in quartz matrix,tight 301.7 (100) hard.to 306.7 273.9(237.2 J Argillite As above,bedding/foliation,40 0 to 50 0 . 275.2-276.0 Fracture zone,joints very closel spaced at 00 ,50 0 and 70 0 ,slickensides. Run 68 274.7- 277.5 96 (50) 305.5-307.7 Fractures very closely spaced, irregular,discontinuous,quartz filling, slickensides at 306.5.~u~n 751100 306.7-(70) 310.4-311.5 Core broken into angular fragment 309.4 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT I ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POIIER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-2 PROJECT Susitna Hydroelectric Project HOLE NO.BH-2 SITE Devil Canyon (North Bank)SHEET NO.11 OF 21 SITE Devil Canyon (North Bank)SHEET NO.12 OF 21 DEPTH {FTJ ROCK TYPE DESCRIPTION COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (Fr.) REC (ROD! DEPTH (FT)ROCK TYPE DESCRI PTION :COLOR,TEXTURE,FOLIATION,,,101 NTI NG,FRACTURING,FAULTI NG, ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC LENGTH OF RUN {FT) REe (ROD) Argillite/up to 1 in~h .wide.Jgint at 30°,.slick~nsides Run 76 67 310 '1 Graywacke and talCj Jglnt at 40 planar,sllckensldes,309 4-(0) (268.5 jQint at lQ ,planar,smooth,with 0.1 inches 311'5311.5 of sllt flne to oarse ralned sand., .---I (269 ..Argillite Rock description,as above,few interbeds of Run 77 100 graywacke.311.5 (94) to 316.7 315.0-316.7 Fracture zone,irregular and dis- continuous fractures,quartz filled,tight, hard. Run 8 100 337.5 339.5 (70) 96 (96) 96 (96) 98 (98) Run 85\100 339.5-(83) 343.1 to 361.9 Run 90 361.9 to 366.7 Run 91 366.7 to 372.0 Run 861100 343.1 (100) to 347.1 Run 89 357.1 Run 881100 352.2 (l00) to 357.1 Run 871100 347.1 (100) to 352.2 359.5-362.0 Fracture zone,joints very closel spaced at 30°,tight. 361.4-364.7 Bedding/foliation at 50 0 . 366.5-366.9 Quartz vein,40 0 ,irregular, parallel to and crosscutting bedding. 364.6 Core loss of 0.2 feet. fine grained medasedimentary rock thinly inter bedded with graywacke,reddish,medium to dark gray,fine to medium grained metasedimentary rock with elongated sand grains.Occasional phyllitic sheen in argillite.Generally fresh, har~well indurated. 340.5-340.6 Quartz vein,folded,tight,hard, inclusions of argillite. 341.5-342.07 Quartz stringers,0.25 inches 342.8-343.3)wide,highly folded and contorted, some gffset along foliation fracture cleavage at 40 ,tight,hard. 344.0 Graywacke beds becoming fine to coarse grained,some 9raded beds,beds generally less than 6 inches wide. Arg ill ite/ Graywacke 370 (320.4 360 (311.8 350 (303.1 Run 821 92 330.1-(56) 332.6 Run 83[67 332.6 (53) to 337.5 Run 81\100 326.9 (91) to 330.1 Run 781 87 316.7 (37) to 319.7 'Run 791100 319.7 (74) to 323.5 318.6-424.1 Joints generally closely to mod- erately closely spaced,occasional zones very closely spaced,generally planar,slick to smooth,tight,chlorite and talc filling quart carbonate and trace clay/silt. 322.3-323.0 Breccia,00 ,healed,tight,hard. 325.00325.5 Bedding,0°,crosscut by foliatio.I ~L-----__f at 50 .Run 80 100325.5-326.6 Numerous quartz veins and strin-323 5 (100) gers,parallel to bedding/foliation,very t' clnsely spaced,50ntorted,chlorite coating.326 09 328.5 Joint,45 ,carbonate,less than 0.1 . inches of silty sand. 328.5 Argillite,reddish gray.0 328.5-329.8 Quartz stringers,60 ,closely spaced,up to 0.25 inches wige,tight .. 329.5"330.4 Quartz vein,20 ,0.5 to 2.0 inches wide,irre9ular,frac6ured,tight. 330.6-330.9 Quartz vein,30 ,1.5 inches wide fractured,tight,chlorite. 332.6-337.5 Core loss of 1.6 feet. 333.3-333.8 Shear/f5acture zone,joints very closely spaced at 20 ,slickensides and silty ""od cQating..334.6-jj4.~Shear,quartz healed,tlght,hard As above,lower contact at 30"'. 320 (277 .1 330 (285.8 334.8 (289.9' 339.ffi ArQillite/ (?QIl <~Gra vwa cke Run 8" 1\~]~~~\~i 'I 1 ~ j ;r ~.'" ·....~~J ~'~l ""._-J -1 -,.:c:~)~._)-J J '0 )OJ J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-2 SHEET NO.13 OF 21 SITE Devil Canyon (North Bank) HOLE NO.BH-2 SHEET NO.14 OF 21 DEPTH (FT,)FiOCK TYPE OESCRIPTI ON :COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN IFf) REC [ROD} DEPTH (FT)FiOCK TYPE DESCRI PTI ON :COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING"LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT) REC [RQD) 416.9 Run 1011 100 416.9 (92) to 421.9 Run 1001 100 411.6 (lOO) to --- 100 (93) Run 98 1------ Run 99 407.1 to 411.6 406.2 Joint,20 0 ,clay filling. Rock description,as above. 410.7 Quartz pod with chlorite stringers, 1 inch wide. Joints generally moderately closely spaced, zones very closely spaced,generally planar to irregular,smooth to rough,tight to open, quartz and carbonate filling,some chlorite staining. 415.9-416.6 Felsic dike (aplite),light gray, highly irregular contacts,stringers penetra- ting graywacke up to 2 inches,tight,hard. Graywacke 410 (355.1) 414.0 t-I (358.5)I Argillite/ Graywacke 420 (363.7) Run 951 96 386.2 (96) to 391.4 Run 931100 376.1 (l00) to 381.1 Run 941100 381.1 (l00) to 386.2 Run 921 95 372.0 (73) to 376.1 374.0 Core loss of 0.2 feet. 375.3 Joint,40°,silty sand fillin9. 383.9-389.5 Beddin9 highly fslded and con- torted,foliation at 40 to 60 parallel to and crosscuttin9 bedding,offsets along foliation. Ar9ill ite Graywacke 380 (329.1 427.2 to 431.9 427.2 I (l00) Run 1031 100 Run 1021 100 421.9 (l00) to Run 1041100 431.9 (94) to 437.2 424.1-562.8 Joints generally moderately closely spaced,planar to irregular,smooth to rough,tight to open,some carbonate filling,very few with quartz and clay filling some chlorite staining. 424.4 Less talc and chlorite on joints below. 426.6-431.9 Core loss of 0.4 feet.. 431.5 Quartz vein,2 inches wide,as above. 420.8-421.2 Quartz stringers.0.25 inches wide,folded,irregular and discontinuous, tight. 422.3-428.0 Quartz veins and stringers less than 1 inch wide,moderately closely to closel spaced,irregular,unfractured,tight, chlorite mineralization. 430 (372.4) 98 (88) 98 (98) Run 97 396.6 to 401.8 Run g81 92 401.8 (89) to 407.1 403.0 Bedding/foliation,60°. 400 (346.4 390 (337.7 391.4-407.1 Core loss of 0.4 feet.Run 96(~~~.~j Graywacke Rock description,as above,few very thin to 39~~4 .thin argillite beds.396.6 Joints closely to moderately closely spaced, generally planar,slick to smooth,tight,few chlorite and talc filled. 394.5 Quartz stringer,70°,0.1 inches wide, crosscutting foliation but slightly offset by fracture cleavage. 394.7 Quartz pod,10°,0.5 inches wide,2 inches long,discontinuous. 400.7-406.0 Core loss of 0.1 feet. ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY PROJECT SUS itna Hydroe 1ectri c Proj ect ClIENT ALASKA POI,ER AUTHORITY PROJECT Susitna Hydroelectric Project SITE Oevil Canyon (North Bank) JOB No.P5700.05 HOLE NO.BH-2 SHEET NO 15 OF 21 SITE Devil Canyon (North Bank) JOB NO.P5700.05 HOLE NO.BH-2 SHEET NO.16 OF 21 DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEnuRE,fOLIATION ,JOI NTI NG,FRACTURING,FAULTI NG, AL.TERATION,WATER LOSS OR GAIN,CAVING,LOST COAE,CEMENTING 1 ETC LENGTH OF RUN (FT.) REC (RQD) DEPTH (FJ.)ROCK TYPE DEseRI PTiON :COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULTI NG, AL.TER ATI ON,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENT!NG,ETC. LENGTH OF RUN (FT.) REC (ROD) Run 1071 98 444.9 (98) to 450.0 Run 1141100 477.3 (l00) to 481.9 Run 111 Run 1131 100 475.0-(l00) 477 .3 Run 1121100 470.3 (85) to 475.0 472.5-473.0 Core badly broken by drilling. 474.0 Quartz vein,90°,1 inch wide,frac- tured,open joint with chlorite. 474.5 Quartz vein,40°,1 inch wide, fractured,tight. Argi 11 ite/ Graywacke470 (407.0) 480 (415.7) 96 (96) to 442.2 Runl05 437.2 439.7-453.6 Quartz veins,20°to 50°,parallel to subparallel to bedding/foliation,3 inches to 6 inches wide,closely spaced,very closely fractured.10%to 20%chlorite mineralization,~~c-.~--1 tight contacts.!Run 106 100 442.2 (l00) to 444.9 Argi 11 ite/ Graywacke 440 (381.1 ) Run 1151 100 481.9 (69) to 485.4 Run 1161100 485.4 (96) to 490.3 450 (389.7) 460 (398.4) Run 1081 98 450.0 (98) to 455.3 Run 1091100 455.3 (l00) to 460.1 Run 1101100 460.1 (l00) to 465.3 Run 1111 100 465.3 (100) to 470.3 490 (424.4) 500 (433.0) 484.4-485.4 Core badly broken by drilling. 490.3-494.7 Shear/fracture zon O'join&s very closely to closely spaced at 30 to 60 ,very thin breccia,clay gouge and carbonate on joint surfaces. 499.8 Joint,50°,clay coating. 500.5 Bedding/foliation,50°. Run 117 490.3- 492.5 Run 118 492.5 to 495.4 Run 119 495.4 to 499.4 100 (18) 100 (72) 100 (9B) )l )j 1;]~]~,~1 .~~.r 'I ,0_]'-']'-~')r o _)~O~)']-,))-'1 ",-~]-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA PO~IER AUTHORITY JOB NO.P5 700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-2 PROJECT Susitna Hydroelectric Project HOLE NO.BH-2 SITE Devil Canyon (North Bank)SHEET NO.17 OF 21 SITE Devil Canyon (North Bank)SHEET NO.18 OF 21 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,,JOI NTING,FRACTURING,FAULTI NG,6~N~J~I RE:C ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTlNG,ETC.In)(RQD) DEPTH (F"T)ROCK TYPE DESCRIPTION;COLO R,TEXTURE,FOLlAT10N,JOI NTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVI NG,.LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.) REC (Rool Run 126 Run 1271 94 534.7 (94) to 538.3 Run 1281 81 538.3 (81) to 542.0 Run 1291100 542.0 (98) to 547.2 Run 1301100 547.2 (100) to 552.0 548.7 Joint with clay filling. 534.7 Core loss of 0.3 feet. 535.6-543.5 Fractures closely spaced, irregular,tight,quartz healed. 54 d.5-547.2 Shear/fracture zone,joint at 10 ,~rregular,sandy silt/clay breccia,joint at 70 ,planar,smooth talc coating.Core badly broken. Argillite/ Graywacke 540 (467.7) 550 (476.3) 98 (91) 100 (100) to 509.1 to 514.0 Run 120 499.4 to 504.7 Run 1221 100 509.1 (84) Run 1231100 514.0 (96) to 519.1 514.3-514.5 Core broken by drilling. 502.2-502.4 Quartz vein,approximately 90°, unfractured,tight,irregulas contact. 503.0-503.1 Quartz vein,60 ,broken by drilling,tight contacts.° 503.3-503.8 Quartz vein,approximately 0 , 0.5 inches to 1 inch wide,folded,unfracturedJRun 121 tight,irregular.1504.7 504.0-505.9 Quartz veins and stringers less than 1 inch wide,folded and offset along foliation,unfractured,tight,hard. 507.2 Quartz pods,0.5 inches to 1 inch wide, as above.I I --I 510.2 Quartz vein,70°,0.5 inches wide, fractured,tight. Argi 11 ite/ Graywacke 510 (441.7) 520 (450.3) 519.5 Bedding/foliation,60°.Run 1241100 519.1 (lOO) to 524.3 Run 1311 94 552.0 (94) to 557.1 Run 1261 100 529.5 (85) to 534.7 530 (459.0) Run 1251100 524.3 (92) to 529.5 529.5 Joint,50°,planar,smooth,clayofillin 1·I I 530.3-531.2 Fracture zone,joints at 0 , irregular,rough,talc and carbonate coating. Core badly broken. 531.2 Quartz vein,50°,0.5 inches to 1.5 inches wide,unfractured,tight. 560 (485.0) 557.1-557.5 Core broken into angular frag- ments,generally less than 0.5 inches. 562.8-621.0 Fractures and joints very closely to closely spaced,calcite and quartz healed, hard,tight. Run 1321100 557.1 (59) to 562.0 Run 1331 100 562.0 (88) to 567.0 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POflER AUTHORITY PROJECT SUS itna Hydroelectric Project JOB NoP5700.05 HOLE NO BH-2 CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project JOB No,P5700.05 HOLE NO,BH-2 SiTE Devil Canyon (North Bank)SHEET NO,19 OF 21 SITE Devil Canyon (North Bank)SHEET NO.20 OF 21 Run 1371 100 579.9 (90) to 582.9 Run 138 100 (20) 584.9-589.6 Co re loss of 0.2 feet.IRun 139 96 584.9 (55) to 589.6 t 620(536.9) Run 140 100 589.6 (68) to 594.6 Run 1341100 567.0 (94) to 572 .1 562.9-592.0 Bedding highly folded,stretched IRun 133 and brecciated along foliation.tight,hard. DEPTH (FT,) 570 (493;6) 580 (.502.3) 590 (511.0) - ROCK TYPE Argill ite/ Graywacke DESCR!.E.I.!.Q.t!:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ALTERATION,WATEA,LOSS OR GAl N,CAVI NG I LOST CORE,CEMENTI NG.ETC 574.4-598.0 Fracture zone,joints and frac- tures very closely spaced,most quartz healed ogenersllyti98t,chlsrite coated,joints at 0 to 20 and 50 to 70 ,fractures,irre9ular and discontinuous.Some core broken by drill in9. LtNGTH OF RUN (FT.) ~un 135 572 .1- 574.6 Run 136 574.6 to 579.9 REe (ROD) 100 (92) 100 (98) DEPTH (FT) 600 (519.6) 610 (528.3) ROGK TYPE Arg ill ite/ Graywacke ~CR\PTI ON :COLOR,TE:<TURE,FOLIATION ,JOI NTING,FRACrURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 601.2-621.0 Fracture zone,joints and trac- tU5es very closely spaced,joints at 10 to 20 ,planar smooth o some talc and carbonate coating,and at 40 to 70 u ,planar to irregular,trace talc and carbonate,fractures irregular and discontinuous,tight. 621.0-656.2 Joints generally widely to very widely spaced,planar,smooth to rough,tight to open,carbonate and quartz filling. 627.3 Shear,60 0 ,1 inch wide,clay and breccia filling,friable.Core loss of 0.2 feet. LENGTH REeOFRUN(ROO)(FT) Run 141 100 594.6 (96 ) 59g~6 RuilT42 100 599.6-(82) 601.8 Run 143 100 601 .8 604.0 (91) ---- Run 144 100 604.0 (88) to 609.2 Run 1451'100 609.2 (76) to 614.2 Run 1461 89 614.2 (81) to 619.5 Run 1471100 619.5 (89) to 624.8 Run f48j 94- 624.8 (89) to 630.1 l A "-}'Th "~]•~]~~~ ,,:\.2 j g S ;~f J ~-')"'1 /~,'--')~?"""J J'~,"''')"")~-],.-~-')'1 -~')1 "''"e'l "~"'-').'--1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY PROJECT SUS itna Hydroe 1ectri c Proj ect JOB NO.P5700.05 HOLE NO.BH-2 SITE Devil Canyon (North Bank)SHEET NO.21 OF 21 DEPTH (FT)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,J01NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. LENGTH OF RUN 1FT.) REC (RQDj 630 (545.6) 632.6 (547.8) Ar9ill ite/ Graywacke Quartz Di orite Granodiorite Dike Li9ht gray,quartz rich rock,porphyritic texture with medium to coarse grained plagio- clase and quartz crystals in a fine grained to aphanitic groundmass of plagioclase and mafics.Overall less than 10%mafics. Generally very hard,fresh,well indurated. Run 148 IRun 1491100 630.1 (l00) to 635.3-r::Run 150 100 635.3 (l00) to 640 (554.3) -650 (562.9) 655.5 (567.7) Joints widely to very widely spaced at 30° '640.5 and 60°to 70°,planar,smooth to rough,tight to open,quartz filling.IRun 1511 98 640.5 (92) to 645.8 646.0-650.1 Quartz veins,closely spaced 1 Run 152 100 inch to 6 inches wide,comprise 50%of rock,645.8 (100) highly fractured,tight,minor chlorite,tooccasionalvugsandrecrystallization. 650.8 Run 153 96 650.8 (96) to 655.5 L END OF BORING /~,-1 '~'-]O"J --->--']/"-j "'~'l -~'J ~)-,'1 '-~'l ]-'.J Acres American Incorporated -Consulting Engineers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG SUMMARY LOG REMARKS END OF BORING 655.5' • Fracture zone. Fracture zone, healed. Fracture zone. Dike,felsic. quartz veins, numerous. quartz diorite dike Shear/fracture zone Job No.P5700.05 Ho Ie No.----'B"-H'---=.2 _ Sheet No._2_of _2__ ROCK TYPE Argi 11 ite/ Graywacke Graywacke Argi 11 i tel I--+-+---H Graywacke ALASKA POWER AUTHORIT~Y __ Susitna Hydroelectric Project Devil Canyon (North Bank) Client Project Site 58 • Shear/fracture zan REMARKS Shear/fracture zan Shear/fracture zan Fracture zone, healed. Joint,slicken-sldes. Shear zone. Fracture zone. -Shears,healed. Job No.P5700.05 Hole No.BH.,---,,2~_ Sheet No._1_of _2_ ROCK TYPE Joints,slicken-sldes.Shear/fracture zone Joints,slicken- sides. ~p Fracture zone. Shear. 8 Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Pro~j~e=ct"--_,, Site _~Lc.an.'lQn,lHorth BilllkL _ 280 300 220 240 200 l2G- 140 160 180 100 -260 .--1 ~~.~"~'j -."~l ]~'D ~--'}·.···-1 ···~--·l ."'.~,.-J 1 "-) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT,ALASKA POWER AUTHORITY JOB NO.,P5700.05 PROJECT,Susitna Hydroelectric Project HOLE NO.:BH-3 SITE:Devil Canyon (South Bank)SHEET NO.1 OF 13 CONTRACTOR,Interstate Exploration Inc.DRILLING DATES,.June 28 TO July 13,1981 LOGGED BY,K.J.White,M.P.Bruen DATE,July 1981 Run 12 47.0 I 100 to (83) 51.7 LENGTH I REC OF RUN (FT.)(RQDl Run 5RUilrrITli 22.0-(53) 2~ Run 7 23.9 1100 to (38) 27.9 Run 8 27.9 1100 to (56) 31.9 Run 9 31.9 100 to (96) 37.0 Run 10 37.0 100 to (94) 42.0 -:T:--Run 11 42.0 100 to (94) 47.0 JOB NO.P5700.05 SHEET NO.2 OF 13 HOLE NO.BH-3 51.7-99.8 -Joints moderately close spaced, iron oxide staining,minor chlorite coating. DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOI NTING,fRACTURING,FAUL.TI NG, AL.TERATION,WATER L.OSS OR GAIN,CAVING,LOST CORE,CEMENTING.He 43.8 -Joint at 50°,open,irregular,rough, iron oxide staining,clay/silt coating. 44.0 -Bedding/foliation,60°,very faint secondary foliation at 10°. 27.8-28.1 -Core broken by drilling,pieces average 1 inch,clay/silt coating. 28.1-51.7 -Joints close to moderately closely spaced,averaging 1 foot,minor iron oxide staining. 21.7-22.5 -Core broken by drilling,pieces 1 inch to 2 inches,iron oxide staining. 22.5-27.8 -Joints close spaced,iron oxide staining is lessening. ROCK TYPE Argi 11 ite DEPTH (FT.) CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) 40 (21.2 30 (15.9) 50 (26.5) % REC (RQO) Run 1 100 100 Run 2 8.0 93 to (0) 10.9 Run 3 10.9 1 100 to (50) 14.7 Run 4 14.7 1 100 to (100) 17.8 Run 5 17.8 1 100 to (67) 22.0 February 1,1982 CASING OIAMETER,NW (3.0")1.O. CORE DIAMETER,NQ (1.75")0.0. DATE: I/~/ DESCRIPTION:COLOR ,TEXTURE,FOLIATION,JOINTING,FRACTUA:ING.FAULTING,I RUN AL.TERATION,WATER LOSS OR GAIN.CAVING,LOST CORE,CEMENTING,ETC.L.ENGTH No sampl es taKen. TOP OF ROCK Medium to dark gray,very fine to fine grained metasedimentary rock.Very thin beds coin- cident with weakly to moderately developed primary foliation.Zones of minor secondary foliation.Occasional very thin to medium beds of light gray,fine grained graywacke.Minor zones of quartz veining. Joints close spaced,iron oxide stained. 7.5-11.4 -Joint spacing is close to very close,iron oxide staining.Beddin9 and primary foliation at 35°to 40°with weakly developed secondary foliation at 20°. 11.4-21.7 -Joints close to moderately close spaced,iron oxide staining. N3,222,146 E615,883 058° 32° Cas i ng Advancer Diamond Core -Triple Tube LATITUDE DEPARTURE AZIMUTH DIP SOIL ROCK ROCK TYPE 'h~)/Clp'2-- Overburaen ELEVATIONS,DATUM MSt,A.S.P.C.,Zone 4 GROUND SURFACE 1398.0 ROCK SURFACE 1394.0 BOTTOM OF HOLE 11 90.7 WATER TABLE 1)Depths measured along hole.True depths in (). 2)All an91es measured to the core axis. OEPTH (FT) DRILLING METHOD: APPROVED: LOCATION: NOTES, 0.0 20 (10.6) 7.5 t-Argill ite (4.0) 10 (5.3 ) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK D R ILL I N G R E PO R T ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SusJtna Hydroe 1ectri c Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET NO 3 OF 13 SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET No.4 OF 13 -I-~ Run 22 Run 19 ~------l--- Run 20 Run 23 101.8 1100 to (71) 107.0 DEPTH (FTJ 60 (31.8) to (37.1) ROCK TYPE Argill ite DESCRIPTION:COLOR,TExTURE,FOLIATION,JOINTING,FRACTURING,FAU LTJ NG,I LENGTH REeOFRUN ROCK Tt?E ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FT.)(ROD) .-- Run 13 Argillite 55.7 -Joint,10 0 ,possible slickensides.I 51.7 100 to (98) 56.5 --- Run 14 56.5 100 I r 90 to (96)(47.7) 61.6 L_ Run 15 ·63.3 -Joint,90',open,irregular,heavy j 61.6 I 100iTonoxidecoatingcomparedtosurroundingto(96)joints.66.1 -- Run 16 66.1 1100 I 1100to(100)(53.0) 71.1 70.2 -Joint,25',possibly open,irregular, rough,heavy iron oxide staining. 72.6 -Joint,20',possibly open,irre9ular,[Run 17 rough,heavy iron oxide staining.71.1 I 100 to (90) 76.3 DESCRJPTI ON;COLOR I TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 90.0 -Bedding/foliation highly folded,55'. Weakly developed secondary foliation at 20'. 91.0-91.2 -Quartz pods,up to 1 inch wide, stretched,unfractured. 93.1-98.3 -Quartz stringers,close spacing, crosscutting bedding/foliation,generally 0.1 inch wide. 94.3 -Joint,60',open,planar,smooth,iron oxide staining. 99.8-101.8 -Quartz vein,highly fractured, broken by drilling along healed fractures, heavy iron oxide staining,possible open joints at 20'.Contains inclusions of argillite up to 0.1 foot wide.Fractured at contacts. 99.8-112.0 -Joints closely spaced. 104.5-105.5 -Quartz vein,highly fractured, no iron oxide staining.Fractures generally tight.Drilling breaks at both contacts. LENGTH OF RUN (FT) 86.5 to 91.6 Run 21 91.6 to 96.8 96.8 to 101.8 REe (ROD) 100 (100) 100 (92) 100 (62) 93 (84) 100 (100) Run 24 107.0 to 112.6 Run 25 112.6 to 117.4 109.3 -Shear,25',has approximately 0.5 inch breccia and gouge,slickensides. 112.0-136.5 -Joints moderately close spaced. 113.0-128.7 -Sandy argillite and graywacke, bedding/foliation at 60'. lID (58.3) 100 (94) 100 (96) Run 19 81.4 to 86.5 f------If----- Run 18 76.3 to 81.480.4 -Joint,30°,open,planar,smooth,iron oxid€stilining.Core broken. 80 (42.4) ~'l lJ 1 -:;,.j ').~,.'1 I .,\J "]l J_~]f"C-~)~~>--J "]'''-l '1 ',....],.-'t ~--) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET NO.5 OF 13 SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET No.6 OF 13 DEPTH (FT.)ROCK TYPE DESCAIPTI ON :COLOR,TEXTURE,FOUATION,JOINTING)FRACTURING,FAULT!NO, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENT!NG I ETC LENGTH OF RUN (FT.) REC (RQD) DEPTH (FT)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOl.lATION ,JOINTING,FRACTURING,FAULTING I Al.TERATlON,WATER LOSS OR GAIN,CAVING,LOST CORE,CEt.lENTING,ETC. l.ENGTH OF RUN (FT.) REC (RQD) Run 301 )~~\-~ Run 29 132.4 1100 to (90) 137.4 180.0-183.0 -Quartz stringers,close to very close spaced,generally parallel to bedding,~I I less than 0.1 inch but up to 1 inch.Contacts tight except open at 182.0. r------I (i:~--jRun36 162.4 90 165.6-174.2 -Joints close to very close I to (78) spaced,tight to partially open,approximately 167.4 25%iron oxide staining. 98 (81) 100 (95 ) 100 (94) 100 (96) Run 39 174.3 to 178.7 Run 37 167;:I ~oo~l (59) Run 38 170.1 95 to (55) 174.3 Run 35 157.4 to 15Z.4 Run 33 149.4 to 152.6 Run 34 152.6 to 157.4 174.1 -Joint,30°,clay/silt coating, possibly slickensides. 174.2-189.6 -Joints closely spaced,light to heavy iron oxide staining. 143.9 -Quartz vein,50°,approximately 0.05 feet wide,core loss.Argillite has a phyllitic appearance at the contact. 144.3-165.6 -Joints close to moderately close spaced. 147.0 -Quartz vein,20°,approximately 0.05 feet wide.Open contacts with iron oxide staining. 148.0 -Bedding/foliation,40°. 149.6-150.1 -Graywacke,fine grained at top to medium grained at bottom,graded bedding at 30°and possibly inverted. 155.5 -Bedding/foliation,40°,secondary foliation at 0°to 100.Phyllitic sheen, poorly developed cleavage. Argillite 180 (95,4) 170 (90.1) 160 (84.8) 150 (79.5) 100 (90) 100 (52 ) 100 (94) 100 (96) 100 (100) Run 31 139.1 to 144.3 Run 32 144.3 to 149.4 Run 27 122.4 to 127.4 Run 28 127.4 to 132.4 Run 26 117 .4 to 122.4 141.3 -Quartz vein,0.1 feet wide,fractured but tight. 142.7 -Quartz vein,0.05 feet wide,fractured but tight at 15°,subparallel to bedding. Upper contact open,lower tight. 143.0 -Joint.60°,possibly open,clay/silt coating. 143.6 -Quartz vein,60°,subparallel to bedding/foliation,approximately 0.05 feet wide. 136.5-144.3 -Joint spacing is close to very closely spaced. 129.2 -Joint,40°,open,irregular,rough, heavy iron oxide staining. 122.4-389.5 -Generally no drilling water return. 123.5-147.0 -Numerous quartz pods and stringers,up to 1 inch wide,folded and stretched,unfractured,spacing moderately close to very close. Argi 11 ite 1 120 {63.6} 130 (68.9) 140 (74.2) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project 'Sl'1:E Devil Canyon (South Bank) HOLE NO.BH-3 SHEET No.7 OF 13 SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET NO.8 OF 13 DEPTH (F1J ROCK TYPE OES'CRIPTfON :COLOR>TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAUL.TI NG, ALTERATION,'WATER L.OSS OR GAIN>CAlli NG,LOST CORE,CEMENTING,nc. LENGTH OF RUN (FT) REC (ROD) DEPTH IFTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOUATION,.JOINTiNG,FRACTURING,FAUL.TI NG, AL.TERATION,WATER Loss OR GAIN,CAlli NG,L.OST CORE,CEMENTING,E:TC, LENGTH OF RUN (FT) REC (ROD) Run 40 178.7-1 96 183.5 (67) Run 47 212.61 100 to (61) 215.7 Argi 11 He 184.1 -Bedding/foliation,30°.I "Run 41 183.5 to 187.4 90 (72) Argi 11 He Run 48 Run 49 82 (76) Run 46 207.7 1100 to (90) 212.6 1------+--- Run 54 242.4-\96 247.4 (78) Run 52 232.2 1100 to (94) 237.4 100 (98) 100 (75) 100 (100) Run 50 222.5 to 227 .4 217.4 to 222.5 ~---+1'-- Run 51 227.4 to 232.2 f---~--Run 53 237.4 100 to (94) 242.4 234.3-253.0 -Quartz stringers,close spaced, parallel to and crosscuttin9 bedding,0.1 inch wide,unfractured.Contacts tight. 228.0 -Bedding/foliation,30°. 240 (127.2) 220 (116.6) 230 (121.g) 100 (84) 100 (98) 100 (71 ) 100 (65) Run 44 197.4 to 202.6 Run 45 202.6 to 207.7 Run 42 187.4 to 192.6 ,---- Run 43 192.6 to '197.4 189.6-257.0 -Joints close to moderately close spaced,light to heavy iron oxide staining, tight to partially open. 193.9-195.0 -Quartz stringers and pods, crosscutting bedding,0.1 inch to 1 inch wide, unfractured.Approximately 10 percent of the zone. 205.0 -Beddin9/foliation,30°. 206.2 -Joint,30°,parallel to bedding,silt/ clay coa ti ng . 210 (111.3)1 200 (106.0) ~190 (100.7) :)J 1.,'1,i }\~)J ~i ]";j!;d J J ".:: 1 --1 1 -}--,--,)'''''--1 --]"'....-J J c-_]-"'1 -)--) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South 8ank) HOLE NO.BH-3 SHEET NO.9 OF 13 SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET NO.10 OF 13 100 (65) REC (RQD) LENGTH OF RUN tn) 64 (36) Run 721 T~ (0) Run 62 276.7 I 100 to (88) 281.7 1--- Run 75 303.6 to 306.9 301.0-302.0 -Core badly broken by drilling,pieces 1 inch to 2 inches. DESeRI?TI ON:COLOR,TEXTURE,FOLlATION,JOINTING,FRACTURING,FAULT!NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 308.2 -Bedding/foliation,20°. 303.6-324.5 -Joints close spaced,trace iron oxide staining. 281.7 I 82 to (48) 286.7 282.9-283.5 -Fracture zone,joint spacing is very close,j oi nts at 10 0 to 20°.1 Run 63 I "'"'Rock description as above.:]un 64 --0-- 286.7-288.4 -Core loss of 1.4 feet.Core un.5 broken by drilling,pieces less than 0.2 feet.Run 66'gO (0) 288.4-303.6 -Probable fracture zone,joint -R-68~-sp~cing i~:lose to very close,trace iron 2~~.7-(0) oXlde stalnlng.291 8.---+289.4-289.7 -Core badly broken,pieces R 69 80 1/2 inch to 1 inch.2~~.8-(0) 289.7-296.8 -Joints at 30°,400,and 60 0,293.8 --- fractures at 00 to 100 and 40°to 50 0.Run 70 293.8 50 294.6-296.6 -Core loss of 1.5 feet.to (0) 296.8-299.3 -Core loss of 1.4 feet.296.8 Run 71 296.8- 299.3 268.2-269.5 -Fracture zone,joints very close Run 59 I ~300 spaced at 50 0 to 70 0.267.0 85 (159.0) 270 ~I to (11) 270.3 (1 d3.I)Run 60 100 272.9-274.1 -Joint,lOa,open,heavy iron (31) ~-- oxide staining.Run 61 274.4-286.7 -Joints close to moderately close 271.9 1100 spaced.to (44) 276.7 DEPTH I DESeR'?TI ON:COLOR,TEXTURE,FOUATION ,JOINTING,FRACTURING,FAULT!NG,LENGTH REC ROCI<TYPE OF RUN ROCK TYPE:tn.}ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTING I ETC.1FT.)(RDDI Argillite Graywacke Run 54 247.0 ~ (130.9)Graywac ke Light to medium 9ray,mostly fine to medium -1 n2809coi,,',",to,,"""''''co,,.ith eo t:jargillaceousmatrix,occasional thin beds of 247.4 100 (148.4) 250 1 dark gray argillite.Fresh,hard,and we]]to (92)Iindurated.Joints close to very close spaced,252.2 (132.5)iron oxide staining. Run 56 254.5 -Bedding/foliation,25 0.1 252 .2 100 to (60) I ~286.7 I257.4 (151.9)Argliine I 257.0-257.4 -Core broken by drilling,pieces 1 inch to 2 inches.I n290257.0-275.2 -Joints close to very close spaced Run 57 (153.7) 1258.8-259.2 -Fracture zone,joints very close 257.4 91 260 ~spaced.60 0 ,iron oxide staining,light coating to (25 ) 1(137.8)of silty clay.1261.8 260.3-260.6 -Core broken by drilling,pieces 1 inch to 2 inches.IRun 58 263.3-264.~-Fra;ture zone,joints very close 261.8 1 100spaced,40 to 60 .to (38) 267.0 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLlE,"ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroe 1ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Uevil Canyon (South Bank) HOL E NO.BH-3 SHEET NO.11 OF 13 SITE Devil Canyon (South Bank) HOLE NO.BH-3 SHEET NO 12 OF 13 LENGTH I REC OF RUN (RODjIFT\ 344.4 1100 to (58) 349.6 DESCI1It-'TI UN;COLOR 1 TExTURE,fOLIATION,JOI NTJNG,fRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOS'T CORE,CEMENTING,ETCROCKTYPE Argi 11 ite DEPTH (n) Run 89 341.1 91 to (12) 3<',4.1 ~f 344.4 (182.3)I ~Iafic Dike Dark green,fine grained igneous rock.Fresh ------I and hard.Sheared contacts wi th brecci a and Run 90 gouge.Joints close spaced,silty sand coating. ~~N~J~I (:~~) (FT.)I Run 77 Run 76 306.9 I 98 to (84) 312.2 312.2 I 61 to (26) 316.8 ~:COLOR,TEXTURE,fOLIATION,JOINTING,FRACTURING,FAULTING, ALTE~~Tl0N,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC 311.1 -Quartz vein,irreoular contact at 30°, unfractured,0.2 feet wide. 312.2-312.8 -Core badly broken by drilling, pieces less than or equal to 0.1 feet. ROCK nPE Argill i te DEPTH 1FT) 310 (164.3) Run 78 Run 7911 OO(100 Run 80 ' 32?6 ,98 to (43) 326.8 316.8 I 45 to (18) 321.7 - 100 (57) 100 (80) 100 (44) 100 (75) Run 96 363.0 to 367.8 357.8 to 363.0 ~n~ 367.8- 370.0-370.3 -Fracture zone,joints VRrv close I 370.5 spaced,fractures at 40'to 50 0 ,silt/clay ~Ru~n~9~8+-----~ coating on joints,possible slickensides.370.3 371.0 -Quartz vein at 30 0 ,unfractured,0.75 to inrh wirlp 374.4 Run 95 361.8-366.6 -Quartz stringers and pods,very close spaced,parallel to bedding,stretched, folded,less than 0.5 inch wide,generally fractured but tight. 362.2-363.1 -Fracture zone,possibly sheared, heavy iron oxide staining,silty clay coating on joints,possibly gouge,pieces 0.25 to 1 inch. 363.1-389.9 -Joints closely to moderately close spaced,very close in some zones,less than 0.3 feet wide. 370 (196.1) 360 (190.8) 350.5-351.1 -Core loss of 0.3 feet.Core Run 91 100(100 350.9 ~badly broken.IRlln q?42 (011 (185.9)1 Argillite Rock description as above.Run 93 351.1-352.8 -Core loss of 0.7 feet.Core 351.1 50 badly broken by drilling.to (12) 352.8-356.6 -Fracture zone,joints very close 354.7 spaced at 30 0 ,50 0 ,60 0 ,and 80 c ,fractures at ~-----f------ 10 0 to 20 0 ,iron oxide staining,minor Run 94 carbonate coating.354.7 100 ..~(1~357.8-362.2 -JOlnts closely spaced,lron 357.8 oxide staining. N/A 96 (0) 53 (0) 68 (11 ) 00(0\ 100 (84) 84,85 Run 88 336.6 to 341.1 331.9 to 333.8 Run 87 333.8 to 336.6 Run 81 326.8 to 329.9 Run 83 237.9-328.7 -Core badly broken by drilling, pieces less than or equal to 0.1 feet. 32:9.9-331.9 -Core loss of 0.7 feet.Core badly broken.Hole grouted and rerJrilled. 331.8-334.7 -Core badly broken,pieces average 1/2 inch to 1 inch. 334.7-352.8 -Joints close spaced,iron oxide staining. 324.5-334.7 -Joints very close to close spaced,iro'n oxide staining. 340 (180.2) 320 (169.6) 330 (174.9) l '1 ,1;"-q 'I 0.11 '\\j ~-:;0, i ;I :; ~~~'-1 ".-,~--]'--1 1 1'-1 ~~.~--)l'1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT .Susitna Hydroelectric Project HOLE NO.BH-3 SITE Devil Canyon (South Bank)SHEET NO.13 OF 13 DEPTH (FTJ ROCK TYPE Ar9i 11 ite DESCRIPTION:COLOR,TEXTURE,rOLIATION,JOINTING,FRACTURING,FAUL.TI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST GORE,CEMENTING,ETC LENGTH 1 RECOFRUN(RQD)(FT.) - Run 98 Run 99 374.4 1 100 to (88) 377 .8 380 (201.4) Run 1O~100 372.8 I (88) to 382.8 Run 1011100 382.8 (94) to 387.8 un 102 100 387.8-(52) 389.9 !R"n 103 (Cll-I 390 (206.7) 391.1 I I .~~207 .3)END OF BORING f I ~J eeJ C'J .e·~···l c·"~l ,el -'''1 ···~····1 ..,.•..]e)_..•.).~<l ....)-]].'''] Acres American Incorporated -Consulting Engineers Buffalo,New York Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG CI i ent ALAS KA POWER AUTHOR lTY Job No.---.1'5700~ Project Susitna Hydroelectric Project Hole No.BH-3 Site Devil Canyon (North B~Sheet No ..-1_of __2_ DEPTH ~"'-(FT)~~~(Kl ern/,ee %%JOIN;6SF/ER ROCK TYPE REMARKS 10 6 \0-4 10-2 20 40 60 eo 20 40 60 00 5 15 20 360 Fracture lone. 380 400 '1186 END OF BORING 391.1 'I---f~+~. " f-- .--f-- f- f---_._-~=f--f-.- r--f-~-- f-..-f-- I---f--- 1---f--- I---"-- I---" I---f--- 1--- liJ and zone. lone. • open. REMARKS Fracture lone. Dike,mafic, eared contacts. 'Quartz stringers. _lQ!'.QEROI:LZ.•5._'_ -Joint,open. slickensides open. open. Job No.P5700.05 Hole No._.e.B'-CH--'3'--_ Sheet No._1_of _2_ ROCK TYPE LOGSUMMARY Client ALASKA POWER AUTHOR",IT.'..Y~~. Project ~.M..1iY.droe1ectri c~P~r~o~j",ec",t,--_ Site Devil Canyon (North Banll 60 40 340 80 320 200 220 240 180 160 120 140 100 ~'-~"TCJ '-I "TCO'-"l '1 00"]"0-····"J "-I ~l -T-)"'l ""''')-] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK o R I LLI N G R E PORT CLIENT:ALASKA POWER AUTHORITY JOB NO.,P5700.05 PROJECT,Susitna Hydroelectric Project HOLE NO.,BH-4 SITE,Devil Canyon (South Bank)SHEET NO.1 OF 16 CONTRACrpR,The Drilling Company DRILLING DATES,.August 14 TO August 19,19S0 LOGGED BL K.J.White,M.P.Bruen DATE,July 1981 APPROVED,vlfi5 7J!LW7 LATITUDE N3,222.004 ELEVATIONS,OATUM MSL,A.S.P.C.,Zone 4 OEPARTURE E6l5,992 GROUND SURFACE 1352.6 AZIMUTH 195°ROCK SURFACE 1345.5 DIP 60°BOTTOM OF HOLE 919.0 WATER TABLE 1321 .6 Depths measured along hole.True depths in (). All angles measured to the core axis. TOP OF ROCK REC (RQD) 100 (92) 98 (98) 95 (88) LENGTH OF RUN (FT.) Run 4 20.4 to 25.4 Run 9 44.0 to 4S.0 Run 5 25.4 I 100to(96) 30.5 ffu~ 30.5 I 100to(49) 34.0 - Run 7 34.0 1 100 to .(100) 39.0 Run 8 39.0 1 100 to (100) 44.0 f---+----1 Run 10 48.0 to 53.1 HOLE NO.BH-4 SHEET NO.2 OF 16 JOB NO P570D.05 OESCRIPTI o~:COLOR,TEXTURE,FOLIATION,JOI NTING,fRACTURING,FAUL.TI NG, ALTERATION!WATER LOSS OR GAIN,CAVING!LosT CORE,CEMENrtNG,ETC 20.S -Quartz vein.50°,crosscutting bedding/ foliation.0.5 inches wide,stretched,tight. 23.0-29.0 -Quartz stringers,0.1 inches wide, closely spaced.irregular,stretched,tight. 50.3 -No iron oxide staining below. Medium to d(lrk gray metasedimentary rock with medium to coarse grained sand in a fine grained argillaceous matrix,sand grains elongate parallel to bedding/foliation. Texture massive to weakly developed foliation coincident with bedding at 20-30°. 35.1-103.1 •Joints generally closely spaced, planar,smooth to rough,tight,carbonate, quartz,chlorite and talc filling,occasional iron oxide staining. 44.0.47.0 -No drilling water return. 45.2-46.4 -Fracture zone,2 inches wide, joints very closely spaced at 15-20°,open, sandy silt/clay coating,iron oxide staining. 47.0-58.1 -Drilling water return 50%. ROcK TYPE Argi 11 ite/ Graywacke Graywacke PROJECT Sus itna Hydroe 1ect ri C Proj ect SITE Devil Canyon (South Sank) CLIENT ALASKA POWER AUTHORITY DEPTH {FT.) 33.9 (29.4) 40 (34.6) 3D (26.0) 50 (43.3) 0/0 REC (RQol CASING DIAMETER:NW (3.0")1.0. CORE DIAMETER,NQ (1,75")0.0. February I,19S2 No Core Taken lorv,WlC'll IIIUUI Ol.I;;U.~ Run 1 12,0 I 75to(31 ) l5.L Run 2 '~lOCto(67) 18.8 -- Run 3 100 (50) DATE: No samples taken. OESCRIPTION:COLOR ,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAUL.TING,I RUN ALTERATION,WATER LOSS oR GAIN,CAVING,LOST CORE,CEMENTING,ETC,LENGTH Argillite,medium to dark gray,fine grained, interbedded with graywacke,medium to dark gray,fine to medium sand grains in an argillaceous matrix,elongate grains parallel to bedding/foliation.Very thin to thin bedding coincident with weakly developed foliation at 20°.Fresh,h"'".._",-"-.._+-" Joints generally close to very close,.planar, smooth to rough,tight to open,quartz and carbonate filling,iron oxide staining. 12.0-15.2 -Core loss of 0.6 feet. 12.0-35.1 -Joints generally close to very close,planar,smooth to rough,tight to open, quartz and carbonate filling,iron oxide staining. 20.0,23.4,29.8 -Joints,20-30°with slicken- sides a~d iron oxide staining,parallel beddiJ1'9/fo 1i ati on. Casin9 Advancer Diamond Core -Triple Tube SOIL ROCK ROCl<TYPE Argi 11 i tel Graywacke Overburden LOCATION, DEPTH (FT.) NOTES,1) 2) DRILLING METHOD, 0.0 20 (17.3) 10 (8.7) 7.0 (6.1 ) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REP(HlT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 SITE Devil Canyon (South Bank)SHEET NO.~OF 16 108.4 (g3.91j9,gil1i'o/V,",1hi"','odd,d "'I",k"",b.,e,'9"'=1 R 24110Graywackebeddedwithargillite,dark gray,very fine un (95 3)to fine grained,bedding coincident with 108.1 .weakly developed foliation at 5-10°,crosscut to by microfolds,poor cleavage,phyllitic sheen 113.3 in places. Joints moderately closely spaced at 20-30°, planar,rough to smooth,tight to open,some I Run 25iFnateandtracesiltfilling.g~:~)Ar9illite Rock description as above.1~~.3 Joints generally moderately closely to widely 117.7 1----+--- Run 21 93.8 ,100 to (100) 98.2 100 (100) 100 (100) 100 (100) 100 (100) Run 23 103.4 to 108.1 LENGTH I RECOFRUN (FT)(RQD) --- Run 19 84.4 I 100to(100) 89.4 Run 22 98.2 to 103.4 I- Run 20 89.4 100 to (100) 93.8 Q..ESCRIPTI ON :COLOR l TEXTURE,FOLIATION,JOI NTlNG,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS DR GAIN,CAVING,LOST CORE,CEMENTING,ETC 102.3-103.1 -Numerous quartz veins and stringers,very closely spaced. 102.9 -Quartz vein,SOc,0.75 inches wide, open contact,trace of sulphur-like mineral. 104.5 -Joint,25°,planar,rough,slicken- sides,carbonate coating. 88.4-90.3 -Rock fragments 0.5 to 1 inch long, stretched,parallel bedding/foliation at 30°. 86.5 -Quartz vein,40°,0.5 inches wide, tight. ROCK TYPE Graywacke DEPTH (FiJ gO (77 .9) 100 (86.6) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 SITE Devil Canyon (South Bank)SHEET NO.3 OF 16 DEPTH DESCRIPTION:COLOR,TEXTURE:,FOLIATION,JOINTING,FRACTURING,FAULTI NG,LENGTH R~,C ROCK TYPE OF RUN(FTJ AL.TERATION,WATER Loss OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FT.)(ROD) Graywacke Run 11 53.1 100 to (100) 58.2 f------- Run 12 60 58.2 100 (52.0)to (88) 61.5 Run 13 61.5 100 to (100) 65.7 Run 14 65.7 100 to (100) 70.2 70 --(60.6)Run 15 70.2 1DO to (98) 75.0 Run 16 75.0 92 to (92) 80.2 80 (69.3)Run 17 1OO(86 Run 18 80.9 100 83.2 -Quartz veins,40°,0.5 inches wide,to (100)tight,sulphide mineralization.8~.4 '"~1 ]'I ]'I ~q 1 ;~lJi.' '""'~]'-"-~1 '-~l "--1 ,.,-],...•,':]"~']''']'-'--]_...]------1 ---1 '-'-1 --"-'1 -~---l ""'-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-4 SHEET NO.5 OF 16 SITE Devil Canyon (South Bank) HOLE NO BH-4 SHEET NO.6 OF 16 spaced with zones very closely spaced,planar,~--~~--C~~ few irregular,rough to smooth,tight to open,Run 26 lao few slickensides,carbonate,quartz,talc,117.7-(100) and chlorite coating.~1_2_0._0 ~~ DEPTH (FT.) 120 (103.9) 130 (112.6) 140 (121.2) ROCK TYPE Argillite DESCRIPTION;COLOR,TEXTURE,FOLIATION ,.)01 NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING.LOST CORE,CEMENTING I ETC 135.5-140.5 -Core loss of 0.3 feet. 140.5-240.3 -Drill water return less than ~%. LENGTH OF RUN (FT.) Run 27 120.0 to 125.0 Run 28 125.0 to 130.2 Run 29 130.2 to 135.5 I I Run 30 135.5 to 140.5 Run 31 140.5 to 145.6 Run jZ 145.6 to 150.8 ROC (RQD) 100 (100) 100 (100) 100 (100) 94 (88) 100 (100) 100 (100) DEPTH iFTJ 150 (129.9) 160 (138.6) 170 (147.2) 180 (155.9) ROCK TYPE Argillite DESCRIPTION:COLO R,TEXTURE,FOLIATION ,JOI NT1NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING ,.ETC 157.0 -Joint,20°.with slickensides. 161.7 -Argillite becoming reddish.dark gray,massive to weakly developed foliation. Fresh,hard to very hard,well indurated. 169.5-170.4 -Quartz veins. 171.3-172.3 -Quartz veins and stringers, slickensides,sulphide mineralization, poorly indurated.Core broken and ground by drilling. 178.5 -Joint,35°,with slickensides. 178.5-181.6 -Joint surfaces talc coated. Core broken by drilling,fragments 0.05 to 0.1 feet. LENGTH OF RUN (FT.) Run 32 Run 33 150.8 to 155.9 Run 34 155.9 to 160.9 Run 35 160.9 to 165.9 Run 36 165.9 to 170.9 Run 37 170.9 to 176.1 Run 38 176.1 to '179.6 REC (ROD) 100 (100) 100 (100) 98 (98) 98 (96) 100 (90) 100 (77) i ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULnNG ENG"~EEflS BUFFIILO ,flEW YOFi~ ORllUI;1Ci REPOI1lT CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-4 SHEET NO.7 OF 16 SITE Devil Canyon (South 8ank) .iDLE NO.8H-4 SHEET NO.8 OF 16 I-I -i LENGTH I REC OF "UN (ROO!(FT) Run 39 179.~100to(100) 184.01-- Run 40 184.0 1 100 to (100) 189.1 Run 45 209.6 I 94 to (75) 214.9 Run 49 230.1 I 96 to (85) 235.5 l-- I Run 50 100235.5 I to (83) 240.3 -- Run 51 240.3 I 98 to (98) 245.6 DEPTH I FTl 190 (164.5) 200 (173.2) 210 (181.9) ROCK TYPE Argill ite D[SCRI prl ON COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG 1 ALTERATION,WATER LOSS DR GAIN,CAVING,LOST CORE,CEMENTING,ETC 184.2-188.5 -Joints,15 0 and 30 0 ,with slickensides. 199.8-201.6 -Quartz vein,10 0 ,0.5 inches wide,fractured,possibly slickensides,talc coating,contact partially open. 206.8-207.4 -Quartz vein at 00 ,0.5 inches wide,irregular,stretched,tight. 207.6-211.6 -Fractures very closely spaced, irregular,discontinuous,some quartz filled. 211.5-213.2 -Quartz vein,10 0 ,crosscutting foliation,0.5 inches wide,40%chlorite in layers and pods,sulphide mineralization. Run 41 189.1 to 194.3 ---- Run 42 194.3 to 199.6 Run 43 199.6 to 204.6 Run 44 204.6 to 209.6 100 (94) 100 (100) 100 (100) 100 (100) DEPTH (F1,) 220 (190.5) 230 (199.2) 240 (207.8) ROCK T'r'PE !lrgi 11 ite r DESC:IPTION COLO R,T~'XTURE,FOLIATION 1 JOINTING I FRACTURING,FAULTI NG, -ALTERATION,WATER LOSS OF!GAl N,CAYI NG,LOST COREl CEMENTING,ETC 213.5-213.7 -Quartz veins,0.5 inches wide, irregular,folded,tight. 214.2 -Quartz vein,20°,parallel to bedding/ foliation,0,5 inches wide. 214.9 -Core loss of 0.3 feet. 216.8-220.0 -Quartz veins,closely spaced, less than 0.5 inches wide,tight,crosscutting bedding/foliation at 0-10°but offset along cleavage planes. 221.0-252.0 -Shear/fracture zone,healed, 30-40%folded and nonfolded quartz veins. Folded veins contorted and stretched in matrix of argillite breccia,Nonfolded veins cross- cutting bedd'ing/foliation,vuggy with chlorite and iron and lead sulphides.Generally tight. 230.1-235.5 -Core loss of 0,2 feet. 233.8-328.3 -Joints generally closely spaced, planar,some curved and irregular,slick to rough,tight,some open,carbonate,quartz, chlorite,and talc coating. 236.2-240.9 -Fracture zone,very closely to closely spaced joints at 0°to 10 0 ,slick, talc and carbonate coating,possible slicken- sides. 240.3-240.9 -Core loss of 0.1 feet. 243.9, 245.8,249.6 -Faint slickensides. LENGTH OF RUN (FT) Run 45 Run 46 214.9 to 220.2 Run 47 220.2 to 225.3 Run 48 225.3 to 230.1 REC (ROD) 100 (100) 100 (96) 98 (98) ?!]~~]~~~J 11 3 :~d ,j j:1 ':i il J 1 _~i '1 ~'---~~J ~-'--'')'---'1 '---~l '-----~-1 ,-.-']'C-]1 ,--)._.,._.]"-'-~J '---]---I '---1 '---'1 ] ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700,05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700,05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-4 SHEET NO,9 OF 16 SITE Devil Canyon (South Bank) HOLE NO,BH-4 SHEET NO,10 OF 16 DEPTH (IT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC LENGTH OF RUN {fT.l REC (ROO) DEPTH (FT.)ROCK TYPE OESCRIPTI ON :COLOR,TEXTURE,fOLIATION ,JOI NTING,FRACTURINI;O,FAULTI NG, ALTERATION,wATER LOSS OR GAIN,CAYI NG,l.OST CORE,CEMENTING I ETC LENGTH OF RUN (FT.) REC (ROD) 91 (87) 94 (94) 90 (90) 84 (55) 100 (33) 100 (96) 100 (92) Run 64 293.5 to 297.9 Run 62 286.0 to 290.5 Run 60 277 .3 to 281.0 Run 65 297.9 to 301.9 Run 61 281.0 to 286.0 IKun b.J 290.5 to 293.5 1----T-----1 Run 66 301.9 to 307.0 282.3-287,8 -Quartz vein,fractured but tight, chlorite and sulphide mineralization. 284,6-285.1 -Shear,100,0.5 inches of breccia,chlorite,talc and carbonate coating. 286.0 -Core loss of 0.4 feet. 307.6-309.6,309.6-311.2 -Bedding planes,10°, with slickensides.1-----+---1IRun671308.1-311.5 -Joints subparallel to core axis. 278,1-280.8 -Joints,70°and 00,with sl i ckensides. 292.9-295.6 -Shear zone,100,parallel to foliation,slick surfaces with talc coating, breccia and gouge on some surfaces,fragment of breccia/gouge 2 inches wide at 295.5. 8reccia contains angular fragments in a clay matrix.Core loss of 0.7 feet at 293,5. 301 .9-307.0 -Core los s of 0.7 feet. Argill ite 300 (259.8) 290 (251.1) 280 (242.5) 92 (72) 100 (98) 100 (91 ) 98 (94) 96 (52) 100 (100) 100 (100) 100 (100) Run 57 Run 59 272,3 to 277 ,3 Run 58 267.6 to 272.3 Run 55 255.2 to 260.3 Run 52 245.6- 247.8 Run 56 260.3- 262.6 Rlm 53 247,8- 250.3 262.6 to biotite 1267,6 at 50~ 246,8-247,0 -Quartz vein,0.6 feet wide, fractured,vuggy with iron and lead sulphides, carbonate and chlorite at contacts. Rock description as above. 266.8-279.5 -Numerous quartz veins and stringers.Veins closely to moderately closely spaced at 30°to 40°,crosscutting bedding/ foliation,0.5 inches to 8 inches wide, fractured but tight.Sulphide,chlorite and carbonate mineralization present.8etween 270.6 to 272,4 broken by drilling.Stringers less than 0,5 inches wide,parallel to bedding/ foliation,folded,stretched,tight. 248,8-249,1 -Quartz vein,30°,fractured but tight,open joints at contacts with talc, chlorite and possibly slickensides. 262.3 -Quartz vein,20°,2 inches wide,vu99Y with sulphide mineralization,tight. 263.8-264.4 -Quartz vein,fractured,tight to partially open,vuggy with sulphide minerali- zation,lower contact open. 264.7-308.5 -Ar9illite "spotted"with (7),microfolds crosscuttin9 foliation Arg ill ite Argillite 270 (233.8) 267.u (231.2' Run 54 252.0 1---_~(218.2)1 Argillite/Interbedded argillite and graywacke,as above.250.3 Graywacke Very thin to thin bedding.Joints generally to closely spaced,planar,smooth,tight,quartz 255.2 carbonate,chlorite and talc filling. 254.0-258.1 -Quartz veins,closely spaced, 0.5 to 1 inch wide,folded,tight, 257.3 -Core loss of 0.1 feet, 257,8 -Quartz vein,20°,1 inch wide, fractured but tight,vuggy with sulphide mineralization. 250 (216.5) 260 (225.z) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUffALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUffALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Devi 1 Canyon (South Bank) HOLE NO.BH-4 SHEET NO.11 OF 16 PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South 8ank) HOLE NO.BH-4 SHEET NO.120F 16 DEPTH (fT.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG, ~ERATION.WATER LOSS OR GAIN,CAVING,L.OST CORE,CEMENTING I ETC LENGTH OF RUN (FrJ <Eo (ROD) DEPTH (Fl)ROCK TYPE OEseR I PTION ;COLOR,TEXTURE,FOLIATION 1 JOINTI NG,FRACTURING,FAULTI f\lG > ALTERATION,WATER LOSS OR GAIN,CAVI NG,LOST CORE,CEMENTI NG I E:TC LENGTH OF RUN (FT) REG (RQD) 96 (91) 100 (97) 100 (94 ) 93 (93) 87 (77) 100 (100) 100 (100) Run 77 353.5 to 356.5 Run 78 356.5 to 361.0 Run 74 342.4 to 347.0 Run 73 ~un 751 347.0 to 350.0 f--- R 366.3 to 371.0 1------+--- 343.9-345.0 -Quartz vein. 349.8 -Joint,20°,with slickensides. 347.0 -Core loss of 0.2 feet. Argi 11 ite 360 (311 .8) 362.5~k :jRun 79(313.9)j------Argillite Rock description as above.361.0 Joints generally closely to moderately closely 3~~3 spaced,planar to irregular,smooth to rough,. tight to open,quartz,carbonate and chlorite fillin9· 362.5-364.5 ~ 370.7-376.3 ~Quartz vein,very closely spaced fractures,generally tight,some open,vuggy, chlorite,carbonate,and iron and lead sulphide mineralization,contacts at 10°to 20°, parallel to and crosscutting bedding/foliation at 10°and 20',respectively.I I 371.0-379.4 -Core loss of 2.0 feet. 370 (320.4) 350 (303.1)~~JRun 76 351.2 Argillite/.Interbedded argillite and graywacke,as above.3~2'0 (304.1)Graywacke Joints genera11y closely spaced,mostly planar,353 5 smooth to rough,ti9ht to partially open,. quartz and carbonate filling,2 joints with chlorite coating. 353.5 -Core loss of 0.4 feet. 96 (96) 98 (98) 98 (98) 100 (98) 100 (88) 96 (96) 100 (100) Run 73 337.3 to 342.4 Run 71 327 .2 to 332.2 Run 72 332.2 to 337.3 Run 70 322.0 to 327 .2 Run 69 317.0 to 322.0 339.3 -Core loss of 0.2 feet. 328.3-385.6 -Joints generally closely to moderately closely spaced,planar to irregular, smooth to rough,tight to open,quartz and carbonate fillin9.chlorite coatin9' 330.4-331.1 -Joint,20°,open. 310.0-318.0 -Quartz veins and stringers,up to Run 67 1 inch wide,folded,parallel to bedding/307.0 foliation and crosscutting veins with open to fractures and sulphide and talc minera1ization·r3~1~2~.2=--~___ 312.2 -Core loss of 0.2 feet.Run 68 312.2 to 317.0 Argi 11 ite 340 (294.4) 330 (285.8) 320 (277.1 ) 310 (268.5) !l .~~fJ j 1!]~-1 ~l 3 ~J ~';1 .:J j J --1 1 J J J "~J --~--]-eJ 1 J 1 '---1 -1 "1 \ ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY JOB NO.P5 700.05 CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hvdroe1ectric Project SITE Devi 1 Canyon (South Bank) HOLE NO.BH-4 SHEET NO.13 OF 16 PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-4 SHEET NO.14 OF 16 OEPTH (FT.)ROCK T1'PE: DESCRJPTION;COLOR,TEXTURE,FOl\ATION,JOINTING,FRACTURING.FAULTING, ALTERATION,WATER l.OSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT::) REC (ROD) DEPTH (FT)ROCK T'l'PE DEseRt PTION :COLOR,TEXTURE,fOLIATION,JOINTI NG,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (FT) REC [RQO) Run 87 401.1 to 406.1 100 (96) 98 (98) 100 (100) 100 (100) 100 (100) 100 (100) Run 93 430.3 to 435.1 Run 91 420.0 to 425.0 Run 92 425.0 to 430.3 Run 89 411.1 to 416.2 Run 88 406.1 to 411.1 Run 87 1-----+----1Run90 416.2 to 420.0 435.2-435.6 -Quartz stringers,generally at 0°,less than 0.5 inches wide,parallel to and ~I I crosscutting bedding/foliation. 406.5-410.4 -Graywacke interbedded with argillite,very thin to thin beds. Argi 11 ite 430 (372.4) 420 (363.7) 410 (355.1) 98 (98) 100 (84) 100 (88) 97 (97) 88 (88) 92 (92) 90 (79) Run 83 Run 82 376.5 to 379.4 Run 81 371.0 to 376.5 Run 85 390.8 to 396.0 379.4 to 386.0 385.6-437.8 -Joints generally closely to very closely spaced,planar,mostly smooth,tight, carbonate,quartz,chlorite and talc filling. 376.3-387.0 -Foliation better developed at 10°_20°,phyllitic sheen,poor cleavage. 379.4-386.0 -Core barrel mislatched during drilling,core badly broken.Core loss of 0.2 feet. 396.3-396.8 -Quartz vein,60°,very closely spaced fractures,generally tight,upper contact open,lower contact tight. Arg illite Run 86 396.0 398.6~+-----~to(345.2)Argillite I Rock description as above.401.1 400 - (346.4) 390 (337.7) 380 (329.1) 387.1+--I :.l Run 84(335.2)1 Graywacke Medium gray metasedimentary rock with fine to 386 0 medium grained sand in an argillaceous matrix,to' with very thin argillite layers.390.8 Joints closely to moderately closely spaced, planar,slick to rough,tight,chlorite and talc filling. 390.8-396.0 -Core loss of 1.0 feet. 393.9 -Bedding/foliation,20°. ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFfALO 1 NEW YORK BUffALO,NEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.PS700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.PS700.0S PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 PROJECT Susitna Hydroelectric Project HOLE NO.BH-4 SITE Devil Canyon (South Bank)SHEET NO.lS OF 16 SITE Devil Canyon (South Bank)SHEET NO.16 OF 16 DEPTH I DESCRIPTION COLOR,T"TURE,FOLIATiON ,JOINTING,FRACT"R"G.FAULTING,I 6~N~~~REC DEPTH OES~RIPTI ON :COLOR,TE:XTURE,FOLIATiON,JOINTI NG,FRACTURING,FAU LTI NG l LENGTH I REC ROCK TYPE ROCK TYPE OF HUN (FT.l ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE:,CE:MENTING.ETC,I (FT)(ROD]{FTJ ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC (FT)(ROD) Argi 11 He I IRun 94 Arg i 11 He Run 102-.43S.1 100 470 to (96)(407.0)471.0 -Bedding/foliation,lS". 440 440.1 (381.1) -,Run 103 441.8 Run 95 471'S1100 (382.6 ,-to (100) Argill He/Interbedded argillite and graywacke.Rock 440.1 100 47S.S Graywacke description as above.Thin bedding coincident to (100)----1----with foliation at lS".foliation better 445.1 developed in argillite than in graywacke,Run 104 phyl1itic sheen,poor cleavage.475.5 I 100 Joints generally closely to very closely Run 96 to (94) spaced,at bedding contacts,joints very 480.5 445.1 100closelyspacedingraywacke,without pene-to (94)480tratingargillite.Joints generally planar, slick to smooth,tight,chlorite,talc and 450.2 (415.7)------1--- 450 ~Icarbonate filling.Run 105 (389.7)IRun 97 480.5 I 98 4S0,2 100 to (98) to (100)485.5 4S3.8 48S.9 -Core loss of 0.2 feet. 455.0-457.8 -C",",k'4 do,i4g d,i'li4,[;;;g,100 Run 106 along very closely to closely spaced joints (44)485.51 96 at 20"to 40',most surfaces coated with talc,Run 99 100(63)to (96) chlorite,and carbonate.Run 100 490.S 456.4 100 490 to (80)(424.4) 460 ~I /460.5 j Run 107 (398.4)490.51 100 Run 101 to (96) 495.7 460.5 100 to (94) 46S.7 Run 108 46S 8 t A "11't I-ROCk description as above.~g~r,1 1 49s.71 100 (403:4)rgl 1 e I to (100) 465.7 100 SOO.7 to (100)500.7 I471.S (433.6,i END OF BORING ~~~]]]~j 1 ]-:>l K J ~'i ~}~~~J j ,:j "-1 1 .""1 '~l .~--,C""'""')C"..,~J ~~"l ....'J 1 ]-1 --"-1 "~~"-1 '-1 ")~~J Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG SUMMARY LOG Job No.P5700.05 Hole No.BH-4 Sheet No._1_of _._2_ • REMARKS END OF BORING 500.7' Quartz veins. Job No.P5700.05 Hole No._B"'H"'-24 _ Sheet No._2_of ~2~~ ROCK TYPE Argill ite Graywacke Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Devil Canyon (South Bank) 440 -J-----a.+-I-l-l-.I- 50 963&-J.-1-f-+-!- 420 +-/11II I I I I I 460 I 11I1 I I I I I 380 360+--11IIII I i I '.' 4 00 +1 007-11+-+-I-l-+-I- ~E:T:~I f;~.~·REMARKS Fracture zone. ill Fracture zone. Quartz veins. Quartz veins. Joints,slicken- sides. Quartz veins. ROel<TYPE Argi 11 ite Graywacke ~Argillite ALASKA POWER AUTHORIT~Y ~___ Susitna Hydroelectric Project Devil Canyon (south Bank) Client Project Site o 2a+-----11III++-1 40 D{E:r~~I ~~.~. 100 120 140 160 180 20 220 240 ---+113 26 28 ;;t1~9 32 - 34 -0-1 ···-1 J ...--],.....)1 ·"·..··1 cc-'l ..~]"--'-l -1 -)1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT,ALASKA POWER AUTHORITY JOB NO.:P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric ProjectPROJECT: SITE: Susitna Hydroelectric Project Devil Canyon (North Bank) HOLE NO.:BH-5a SHEET NO.1 OF 20 SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.2 OF 20 CONTRACrpR:Interstate Exploration Inc.DRILLING DATES,.June 4 TO June 15,1981 LOGGED BL R. R.Henschel DATE:July 1981 REC (RQD) LENGTH Of RUN (FT) Run 11 22.8 I 35to(0) 28.5 DESeRI?TI ON :COLOR,TEXTURE,fOLIATION ,JOINTING,FRACTURING,fAuLTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETG 22.8-30.3 -Fracture zone,joints very closelylRun 10 spaced,fragments hard and well indurated. Core broken by drilling.Some core loss. ROCK TYPE Argi 11 ite DEPTH [IT.) CASING DIAMETER,N>I (3.0")J.D. CORE DIAMETER,NQ (1.75")0.0. A.S.P.C.,Zone 4 974.5 974.5 551.7 Diamond Core -Triple Tube LATITUDE N3,222,961 DEPARTURE E616,646 AZIMUTH 189' DIP 45' SOIL ROCK ELEVATIONS,DATUM MSL, GROUND SURFACE ROCK SURFACE BOTTOM OF HOLE WATER TABLE 1)Depths measured along hole.True depths in (). 2)All angles measured to the core axis. DRILLING METHOD: LOCATION: NOTES, Dark gray to black,very fine ~rained meta- sedimentary rock.Bedding generally coincident with weakly developed foliation at 20'to 25°. Occasional very thin beds of light to medium gray,fine grained ~raywacke.Occasional fresh' sulphide mineralization.Slightly phyllitic locally.Generally fresh to sliqhtly weathered,hard,brittle,well indurated. Joints generally closely to moderately closely spaced,planar to irregular,rough to smooth, tight to partially open,iron oxide staining. 0.0-1.5 -Core broken by drilling.Core loss of 0.8 feet. 0.0-42.6 -Joints and fractures very closely to closely spaced,joints at 20-25'and 40' crosscutting bedding/foliation and at 20-25° parallel to bedding/foliation,planar to irregular,smooth to rough,tight to partially open,heavy iron oxide staining and filling. 8.2-10.4 -Core broken by drilling.Core loss of 0.2 feet. 14.2-15.0 -Zone of very closely spaced joints at 100,30°,60-70°. 16.0-16.6 -Core broken by drilling.Core loss of 0.2 feet. /.1.;1, v/vI~/Jl1C{/h.. .QESCRI PTION,COLOR .TEXTURE,FOLIATiON,JOINTING.FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN I CAVING,LOST CORE,CEMENTING,ETC. RUN 0/0 Run 121 73 LENGTH REC 28.5-(18)(ROO)30 (21.2)30.7Run131.2-31.7 -Core loss due to mechanical -- 0.0-60 problems.Hole caving badly,6.0 feet Run 13 50 (40) 2.0 (25)reamed to 31.7.Run 14 75 Run 2 92 (0)33.7-35.7 -Fractures very closely spaced,31.7-(35) 33.7 Run 3 --fragments hard and well indurated.Core I:ij 100 3.2-100 broken by drilling.(30) 5.5 (91)Run 16 Run 4 35.2 90 5.5-100 to (64) 8.0 (80)38.2 RUn Run 5 IRun 184040.8-42.6 -Fractures very closely spaced,8.0 94 (28.3)fragments hard and well indurated.Core Run 19 to (39)broken by drilling.Some core loss.40.0 I 50 11 .5 to (0) Run 6 100 42.6-114.0 -Joints,close to moderately 42.6 (75)close spaced,iron stained,generally tight.Run 20 --42.6-100R.un 7 91 (0)44.6 Run 8 Run 21 100(39) 14.2-79 46.0 -Bedding becomes less distinct with Run 22 16.6 (38)general trend 0_5',syndepositional 45.5- Run 9 100 deformation.47.8 (100)lfLin ---47.8- Run 10 I 49.818.2 100 50 --- I to (94)(35.4)Run 24 ??R 49.8 1100to(100) 53.0February1;1982DATE: ROCK TYPE Arg illite DEPTH (FT.) APPROVED: 0.0 20 (14.1) 10 (7.1) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK BUFFA LO I NEW YORK DR IL LI NG REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-5a PROJECT Susitna Hydroelectric Project HOLE NO.BH-5a SITE Devil Canyon (North Bank)SHEET NO.3 OF 20 SITE Devil Canyon (North Bank)SHEET NO.4 OF 20 Run 27 62.7 1 100 to (94) 67.9-70.8 -Joints,average 30'and 50 0 ,iron'67.7 oxide and silt fillings.~100 Run 28 (70.7) 67.7 98 to (94) 72.5 73.9-74.4 -Fracture zone,healed with IRun 29carbonate,hard. 72.5 88 to (78) 75.7 76.7-77.2 -Fracture zone,joints at 300 and 0 0 40',closely to very closely spaced,iron oxide staining. ill 0Run32(77 .8) 80.4-95.0 -Quartz stringers,20°,crosscut 78.3-100 80.4 (90)bedding.,very thin.Run 33 82.0-85.3 -Bedding/foliation,15°.80.4 1100 to (100) 83.8 --- Run 34 Run 26 57.8 I 92 to (92) 62.7 Run 25 53.0 1100 to (96) 57.8 DEPTH (FT) 60 . (42.4) 70 (49.5) 80 (56.6) ROel<TYPE Argillite DESCRIPTI eN :COLOR,TEXTURE,FOLIAT10N,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAViNG,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.) REe (ROD) DEPTH (FT) (~~.6) ROCK TYPE Argi 11 He DESCRIPTiON:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FALJLTI NG, ALTERATION,WATER 1.055 OR GAIN,CAvl NG,LOST CORE,CEMENTI NG 1 ETC. 86.1-87.0 -Joints,two,15-20°,parallel bedding,slickensides,heavy iron oxide staining with calcareOllS clay. 87.3 -Joint,20°,crosscutting bedding, rough,faint slickensides,iron oxide stained. 90.0 -Joint,30°,faint slickensides,tight. 91.1-92.4 -Bedding/foliation,200 •Joints parallel to and crosscutting bedding,planar, iron oxide and minor carbonate. 98.9-101.2 -Fracture zone,very closely spaced joints at 0-20 0 and 50-80°,rough, irregular,iron oxide staining.Core loss 1 .1 feet. 107.5 -Joint,25°,crosscutting bedding, iron oxide staining. 113.5 -Joint,20°,parallels bedding, slickensides,tight,thin iron oxide and clay coating. 116.0 -Bedding/foliation,10-15 0 ,poorly to well developed.Composition approaching LENG1H R'::COFRUN (FT)(ROD) 83.8-100 86.7 (72) Run 35 86.7 100 to (29) 90.5 ._- Run 36 90.5 I 93 to (82) 95.0 Run 37 95.0 I 97 to (87) 98.0- Run 38 98.0 65 to (35) 102.0 Run 39 Run 40 104.5- 106.0 Run 42 I-- Run 43 108.0- 109.6 Run 45 109.6 92 to (60) 114.1 Run 46 100 (87) J ]~~J <!~,11 ,"A l "1 j!!j1 ~j J J j j 1 ,.~~,-]~~l ""~-l r-~~l '1 ""1 --1 '---1 ----1 ----'-'J -J -1 ,-]-, ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUffALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUffALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.5 OF 20 SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.6 OF 20 DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN (FT.l REC (RODI DEPTH (FT.)ROCK TYPE DESCRfPTI ON :COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,tOST CORE,CEMENTING.ETC LENGTH I REC OF RUN {RQD}(FT) 100 100) 97 (82) Run 62 100 173.0-(100) 175.4 Run 60 163.0 1100 to (68) 168.0 Run 59 158.0 1100 to (86) 163.0 Run 58 154.2 to 158.0 Run 57 149.3 to 154.2 175.0 -Joint,30°,slickensides,tight, chloritized. 154.8-155.8 -Graywacke,fine grained, medi um gray. 155.6-155.9 -Fracture zone,very closely spaced joints at 40-50°,open,carbonate/ limonite stainin9. 156.5 C 156.7 j Joints,50 0 ,open,carbonate and minor 1imonite. 159.4 -Joint,25°,slickensides,carbonate and iron oxide. 166.1 -Joint,20 0 ,crosscuts bedding,well developed slickensides,zones of clay and breccia. 167.9-170.6 -Fractures,irr~gular,healed, very closely spaced. 168.9 -Joint,25°,well developed slickensides,tight,carbonate. 149.5 -Joint,35°,well developed slicken- sides,tight,chloritized. Argi 11 ite - 160 (113.1) Run 63 177.2 175.4 100 (125.5 Argillite/Rock description as above,interbedded Witq to.(100) Graywacke light to medium gray graywacke as stringers. Bedding/foliation generally 0-10°.Localized Run 64 thin phyllitic bands.178.0 96to(89) 183.3 i Run 61(~72~.2 Meta-argi11 ite!-Rock description as above but with PhY11itiCI168.0 I 98sheen.to (86)173.0 170.6-205.5 -Joints,closely spaced. 180 {127.3) 150 (106.1) Run 55 140.91 100 to (100) 145.8 Run 50 123.71 100 to (100) 128.0 Run 52 129.01 100 to (100) 134.0 Run 54 135.91 100 to (94) 140.9 Run 56 145.81 100 to (100) 149.3 Run 511100(100 Run 47 115.91 100 to (71) 120.8 Run 49 pOD (0) Run 48 1100 120.8-(59) 123.0 Run 53 I 100 (47) 146.1-146.8 -Vein,10-15°,sulphide mineralization. 132.0-167.9 -Joint spacing varies from close to wide,average moderately close. 134.0 -Composition becomes progressively more argillaceous,with thin interbeds of graywacke. 134.4-136.0 -Zone of intense syndepositional deformation. 124.8 -Joint,25',parallels bedding,open, carbonate coating. 128.0-134.0 -Fracture zone,joints,closely spaced at 30-35°and 70 0 ,healed. 116.0-121.0 -Joint spacin9 close to moderately close,partly open with iron oxide staining and carbonate. 120.6 -Joint,15 0 ,tight. 121.0-132.2 -Joints,15°and 25-30°,closely to moderately closely spaced,smooth,planar. 122.2-122.5 -Quartz vein,15-20°. Arqi 11 ite 140 (99.0) 130 (90.4) 120 (84.9) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALAS KA POW ER AUTHOR lTY JOB NO,P5700,05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJ,ECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devi']Canyon (North Bank) HOLE NO.BH-5a SHEET NO.7 OF 20 SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.8 OF 20 193.9 -Fracture,50 0 ,_irregular,slickensides'l--~_----l 100 ,(100) 100 (100) 100 (100) Run 77 232.6-100 235.1 (100) Run 78 235.1 100 to (100) 239.5 LENGTH RECOFRUN (FT.)(RQD) Run 72 100 211.3-(80) 215.3 Run 73 215.3 1 100 to (93) 218.3 Run 74 218.3 to 222.8 Run 75 222.8 to 227.8 Run 76 227.8 to 232.6 Run 79 100 89 Run 80 241.3 100 to (100) 244.4 DESCRIPTION:COLOR,TEXTURE,FOUATION,JOINTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAYI NG,LOST CORE,CEMENTING,ETC. 240.8 -Joint,30 0 ,tight,chlorite coating. 244.1-247.1 -Fracture zone,very thin joints, 30 0 ,very closely spaced,healed. 222.5-225.0 -Fractures,healed,very closely spaced and irregular,healed,small quartz vein. 215.0 -Joint,0-10°,possible shear,silt! sandy coating. ROCK TYPE Argi 11 ite DEPTH (FT.) 220 (155.6) 240 (169.7) 230 (162.6) REe (RaO) 100 (77) 100 (63) 96 (96) 100 (88) 66 (23) 100 (100) 100 (100) LENGTH OF RUN (FT.] Run 72 Run 64 Run 71 206.0 to 211.3 Run 66 188.0 to 193.3 Run 67 193.3 to 196.3 Run 70 203.0 to 206.0 Run 69 198.1 to 203.0 OESCRIPTION :COLOR \TExTURE,FOLIATION ,JOINTING,FRACTURING,FAuLTI NG, AL.TERATION,WATER LOSS OR GAIN,CAVING ,LOST CORE,CEMENTING,ETC 183.3-188.0 -Core barrel mislatch.Core loss ~----I-----t 1 .3 feet.Run 65 183.3 to 188.0 203.0-217.0 -Fractures,numerous,healed. 203.2 -Joint,20°,crosscuts bedding, faint slickensides. 203.5-204.0 -Fracture and quartz stringers,15 0 ,tight,irregular,highly chloritized. 205.5-251.7 -Intermi ttant wavy bands and stringers of graywacke.Joints moderately close to widely spaced at 0-15 0 • 190·21 190.4)Joints,30-50 0 ,irregular,partly open,slickensides. 187.1-187.3 -Ouartz vein,20 0 • 18&.0-191.9 -Fracture zone,well healed fractures. ROCK T'T'PE Ar9i 11 ite! Graywacke DEPTH (FT.1 210 (l48.5) 200 (141.4) 197 l-A 'll't I R k d ..b .h"IRun 68(139.3)1 ,rgl 1 eoc eSCrlptlon as a ove,wlth t ln lnter- beds of graywacke locally.Joints,tight. 190 (134.4) ,~4 ~'1 j 1]1 -'1 j ~]~-;1 j ~ 1 '·~~1 ~~..]~~]·,'''····1 c.,.c e -,c'----·l ---~._'--~)-c'~]'-"j -~-~l '··'1 -"'--1 -··-1 J ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK BUFFALO.NEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.SH-5a PROJECT Susitna Hydroelectric Project HOLE NO.SH-5a SITE Devil Canyon (North Sank)SHEET NO.9 OF 20 SITE Devil Canyon (North Bank)SHEET NO.10 OF 20 DEPTH (FT.)ROCK TYPE DESCRIPTION:COLOR,TExTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, AL.TERATION,WATER LosS OR GAIN,CAVING,LOST CORE,CEMENTING,nco L~NGTH OF RUN (FI) REC (ROD) DEPTH (fTJ ROCK TYPE Q.ESCRIPTION :COLOR,TEXTURE,FOUAT10N,JOINTI NG,FRACTURING,fAUL.TI NG, ALTE:RATION.WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH OF RUN 1FT.) REe (RQD) Run 941 100 (0) I RiJn 91 I 72 (31) 98 (93) 100 (88) Run 97 307.2 1100 to (90) 312.0 Run 93 292.4 1 86 to (10) 296.4 Run 92 289.9- 292.4 Run 95 297.g 1100 to (92) 302.9 Run 96 302.9 I 98 to (86) 307.2 Run 90 284.2 to 288.6 Run 88 276.4 I 96 to (96) 281.6 72 (48) ~-+-- I Run 89 I ~~ 281.6 to 284.2 285.6-288.0 -Quartz stringers,irregular. 291.0-297.6 -Shear/fracture zone,joint very closely spaced at 0°and 20-30°,slickensides well developed. 291.0-292.9 -Joint surfaces slick, highly chloritized. 296.3-297.9 -Shear,40°. 296.2-297.6 -Fracture zone,jointed 20-40°, highly chloritized,slickensides. Light to medium gray,fine grained graywacke with thin interbeds of argillite.Bedding/ foliation highly deformed by syndepositional processes,generally at 15°. 297.7-367.4 -Joints moderately closely spaced with zones of very closely to closely spaced.Numerous weakly healed and rebroken. Generally at 20°and 40-50°.Faint slicken- sides. 288.0-289.7 -Fracture zone,closely spaced, open to healed joints at 30°,faint slicken- sides. Ar9i 11 ite Graywacke 290 (205.0) 280 (19B.0) 297.7 (210.5) 300 (212.1~ Run 83 252.4 1100 to (65) 256.7 Run 84 256.7 1100 to (75) 261.8 Run 82 247.4 1100 to (94) 252.4 Run 81 244.~93to(73) 247.4 Run 85 261.8 I 93 to (80) 266.4 f---I (~JRun87 271.2 92 to (71 ) 276.4 I-- Run 86 266.4 100 to (85) 271.2 247.1-252.1 -Core loss 0.4 feet. 273.5 -Fracture,25°,open. 274.8-276.0 -Fracture zone,very closely spaced joints at 0-10°,40°and 60°.Core loss 0.2 feet. 251.7-252.1 -Silty layer,80°,with fresh angular rock fragments.Surrounding core fresh.Appears to be river silt. 251.7 -Fracture.80-90°. 251.7-290.0 -Joints moderately closely spaced with zones of very close spacing. 252.1-252.4 -Joint,30°,crosscuts apparent bedding/foliation.Filled by 1/8 inch clay/ breccia. 252.4-253.9 -Fractures,irregular,0-15°, clay/breccia filling. 264.5-266.1 -Fracture zone of very closely spaced joints at 5°.Chloritization present. Core loss 0.3 feet. 265.4-267.4 -Fracture zone,very closely spaced joints at 20°and 30-40°. 266.5 -Joint,25°,crosscuts bedding,well developed slickensides at 60°,tight. Argi 11 ite 270 (190.9) 260 (183.8) 250 (176.7) 'ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHOR ITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Oevi 1 Canyon (North Bank) HOLE NO.BH-5a SHEET NO.11 Of 20 SITE Oevil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.12 Of 20 DEI='TH (n".)ROCK TYPE DESeRI?TI ON :COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ~N,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC. LENGTH OF RUN (FT.) REC (ROD) DEPTH (FTJ ROCK TYPE DESCRIPTION:COLOR I TEXTURE,FOLiATION,JOI NTI NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC. LENGTH OF RUN (fT.) REG (RQD) Run 10 shearing,133B.3- 343.3 100 (98) 100 (98) 100 (75) 90 (48) 3H .7 to ~i;t'l i; Run 113 368.1 to 373.1 Run 112 363.1 to 368.1 ~--- Run 109 350.51 100 to (79) 354.7f--- Run 110 354.7 I 94 to (59) 358.1 Run 111 358.1 1100 to (96) 363.1 367.4-392.4 -Joint spacing wide to very wide. Thickly bedded at approximately 0_10 0. 361.2-361.5 -Joint,20 0 ,tight,faint slickensides,planar,chloritized. 354.3 -Fracture,10-15 0,irregular,faint slickensides,chloritized. 342.0-348.5 -Fracture/shear zone,very un 105 close ly to close ly spaced fractures,parti ally 106'---1 weakly healed.Joints at 20 0 ,25 0 ,30 0 ,and un 60 0 •Carbonate common.Possibly shearing.3i~·3 342.0-343.5 -Highly fractured zone,346.4 numerous joints at 20-30 0,weakly healed.1--~f--,,-~-1 Core loss 0.6 feet.Run 107 i~~\ RunfOB Graywacke 370 (261.6) 360 (254.5) 350 (247.5) 98 (78) 100 (89) 93 (43) Run 10 334.7 to 338.3 Run 10< 328.3 1100 to (92) 333.3 Run 101 323.9 1100 to (89) 328.3 Run 97 Run 98 312.0 1100 to (85) 317.3 Run 1G31 93 ------+-fl-~ Run 99 317.3 to inch~~_ Run loj 320.3 100 to (78) 323.9 f-- 338.0 -Joint,150,slickensides,tight, highly chloritized. 340.6 -Joint,20-300 ,curved,minor hi ghlych 1oritized. 333.2-333.4 -Joint,25 0 ,crosscuts bedding, healed with clay/breccia and carbonate. 333.3-333.8 -Shear/fracture zone,very clo.sely spaced joints,slickensides. chloritized. 320.5 -Joint,20 0,minor shear with 1/16 Clay/breccia,highly chloritized. 322.0-323.6 -Fracture zone,healed with quartz,joints at 50-60 0 • 325.8-326.4 -Joint,150,minor shearing healed with carbonate,parallels bedding/ foliation. 317.0-317.7 -Fracture zone,very closely spaced joints parallel to bedding/foliation. 34D (240.4) 330 (233.3) 310 J Graywacke (219.2) 320 (226.2) 1\'I ]!1)~~3 l l i ]~l .~ J 21 ,J i 0J CC"'~C"]~~'~l --1 1 "'--1 -,.")"'-c"1 -"')'J ,---I -1 '''J ""1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT OEseRI PTION :COLOR,TEXTURE,FOLIATION,J(l1 NTI NG,FRACTURING,FAUlTI NG,6~N~~~I REe ALTERATION,WATER LOSS OR GAIN,CAVING,",-OST COREl CEMENTING,ETC.(FT)(ROD) CLIENT ALASKA POWER AUTHORITY PROJECT Susitna Hydroelectric Project Run 133 433.61 94to(88) 436.8 I Run 132 428.41 100 to (90) 433.6 Run 128 412.31 100 to (89) 416.8 Run 127 407.4 I 100 to (92) 412.3 Run 129 416.81 100 to (94) 421.9 Run 1301 94 (56) IRun 126 404.6-1 100 407.4 (96) [--I--I Run 131 423.71 98 to (87) 428.4 JOB NO.P5700.05 HOLE NO.BH-5a SHEET NO.14 OF 20 437.8 -Shears,minor,joints at 40°,hi9hly chloritized with very thin coating of clay/ breccia,tight. Rock description as above. 425.7-456.6 -Joints moderately close to widely spaced,average 30°.Low angle set, 15°,hi9hly chloritized. surfaces. ROCK TYPE Ar9i 11 ite Devil Canyon (North Bank) Graywacke SITE DEPTH (FT.) 425.7~301.0) 430 (304.0) 420 (296.9) 410 (289.9) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO,P5700.05 PROJECT Susitna Hydroelectric Project HOLE NQ BH-5a SITE Devil Canyon (North Bank)SHEET NO.13 OF 20 DEPTH DESCRIPTION:COLO R,TEXTURE,fOLIATION I JOINTING,FRACTURING;FAULTI NG,LENGTH REe ROCK TYPE OF RUN (FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC.(FT)(ROO) Graywacke Run 114 373.1 100 to (106) 378.1 Run 115 378.1-100 380 380.5 (91 ) (268.7)Run 116 380.5-100 382.5 (lOa) Rim 117 (~gl Run 118 386.2-387.1 -Fractures,very tight,healed.383.5 100 to (94) 388.2 Run 119 100 390 (73) Run 120 100275.7)(67) Run 121 392.4 391.2-100 (277.4 )Argillite Dark gray to black,very fine grained meta-393.4 (82) sedimentary rock.Sulphide mineralization common.Joint spacing wide to very wide.Run 122 393.4 100 to (94) 396.5 297.6-399.4 -Sandy argillite,very fine Run 123sandgrainsinfinegrainedargillaceous matrix.396.5 100 to (100) 401.3 400 (282.8) Run 12 100 (87) ~aywacke Rock description as above.Joint spacing Run 12 403.l~)wide to very wide.Healed fractures at 20°~gn-}~gl 280.2 and 40°,faint slickensides on chloritized ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK BUFFALO I NEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroe 1ectri c Proj ect HOLE NO.BH-5a PROJECT Susitna Hydroelectric Project HOLE NO.BH-5a SITE Devil Canyon (North Bank)SHEET NO.15 OF 20 SITE Devil Canyon (North Bank)SHEET NO.16 OF 20 DEPTH I DESCRIPTION:COLOR,TFxTUR!:.,FOLIATION ,JOINTI NG,FRACTURINC,fAu I-TI NG,DEPTH DESCRJPTI ON;GOLOR,TExTURE,FOL.IATION,JOINTING,fRACTURING,FAULTI NG,Ll::NGTH I REe ROCK TYPE ROCK TYPE OF RUN (FT.l AL.TERATION,WA:r£R LOSS OR GAIN,CAYI NG,LOST CORE,CEMENTI NG,ETc.(FT.)AL.TERATION,WATER LOSS OR GAIN,CAVING,L.OST CORE,CEMENTING,ETC.(FT.)(ROD) Argill ite 470 Arg ill He Run 141 (322.3)466.9 I 100 to (100) 440 i 1440.4-442.5 -Zone of very closely spaced Run 135 471.9 (311.1)joints at 30-35·,tight,chloritized.438.4 97 Run 142 441.5-442.5 -Shears,20-25°,very closely to (69) 442.9 471.91 100spaced,highly chloritized,slickensides,475.5-475.9 -Ouartz vein,5-10·,1/2 inch to (100)carbonate/gouge/breccia coating.wide.476.9 Run 136 476.8 -Joint,50·,open,planar. 445.0 -Joint,20·,healed,very tight,faint 1 442 .9 100slickensides.to (100)478.6 -Joint,60·,part open,rough.Run 143 446.9 476.9 I 100 480 to (94) IRun 137 I rt333.6)481.9 446.9 98 450 i 1451.6-456.6 -Core barrel mislatch. I to (90) (318.2)452.0 I I I I IRun 144 481.91 100 to (100) Run 138 I I I I I 486.9 452.0 72 to (0) 457.0 f,490 j Run 14E456.6-5.27.4 -Joint spacing generally wide to tun 139 very wide with zones of very close to closely 486.91 100 spaced.Occasional irregular,healed to (96) fractures and quartz stringers.(346.4)491.9 457.0 100 460 i I I to (96) 325.2)461.9 I I I IRun 146 491.91 100 to (82) 'Run 140 r I I I 497.0 461.9 100 to (100) 466.9 I I I IRun 14 497.aI 100 Run 1411 100 I ~500 ~I I to (96) (100)(353.5)502.0 J 1 1 ~]-~~~"1\ry 1 3,J -Cl -]~-CC-"l '-1 "'--1 C"--']~-1 --'1 ~._-)-1 CC~",C}J ) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroe 1ectri c Proj ect PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.17 OF 20 SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.18 OF 20 DEPTH I I DESCRIPTION'COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULT'NG,LENGTH REe DEPTH I ~:COLOR,TEXTURE,FOLIATION,,JOINTING,FRACTURING,FAULTI NG,L.ENGTH REC ROCK TYPE OF RUN ROCK TYPE OF RUN [FT.)ALTERATION,WATER L.OSS OR GAIN,CAVING,1..05T CORE,CEMENTING,ETC (FT)(ROD)(FT.)ALTERATION.WATER LOSS OR GAIN,CAVING,1..0$T CORE,CEMENTING,ETC.IF'T:)(ROO) Argi 11 ite I Run 147 Argill ite Run 148 _~93)Run 156 533.51 98 505.2 -Joint,20°,possible shear healed run 149 to (90) weakly with carbonate.503.4 100 538.5 538.1-540.9 -Shear/fracture zone,healed.to (100)Joints,0_5°,very closely spaced,weakly508.4 healed with carbonate,tight,highly run 157 540 chloritized.538.5-1 100 (381.8)540.7 (0) 540.9-597.7 -Joints,wide to very widely 510 1 I .run 150 I spaced,generally at 20°,healed with carbonat510.4 -Fracture,60°,open,rough,lrregular. f and rebroken by drilling,highly chloritized.Run 158(360.6)508.4 100 Secondary set at 40-45°,moderately closely toto(100)widely spaced,tight.540.7 I 100 513.7 to (46) 513.0 -Shear,40°,highly chloritized,1/16 545.7 inch clayey breccia,slickensides.--- Run 151 515.5-516.B -Fracture,0-20 0 ,very irregular, 513.7/96 I ~j Run l59highlychloritized.to (85) 518.4 545.7 I 98 to (86) 550 550.6 Run IbZ II f388 91 1 29) 520 1 I Run 153 IRun 160(367.6)550.61 100519.8 100 to (100)522.7-527.4 -Shear/fracture zone,joints to (84) very closely spaced at 10°and 20 e ,generally 523.6 I 555.7 irregular,slick,highly chloritized,well ~un 154developedslickensides,carbonate.Core loss 2.4 feet. I Run 161523.6 57 to (12)555.7 I 100 527.4-536.1 -'"ct""""',c";"y t,[,;28"to (100) moderately closely spaced joints and fractures 560.9 at 20-30 0 and 50 0 ,highly chloritized with 560 carbonate.Many are healed,rebroken by 1395 .91 j IR:;-+-~drilling.Run 15 Run 162 530 1 I 528.5 100(374.7)(94)560.91 98toto(88)533.5 565.9 A.CRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK D Rt\.LI NGflE PORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALAS KA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 ,PROJECT 'Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Oevil .Canyon (North Bank) HOLE NO BH-5a SHEET NO.19 OF 20 SITE Devil Canyon (North Bank) HOLE NO.BH-5a SHEET NO.20 OF 20 DEPTH (IT)ROCK TY"E DESC;RI?!I ON:COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULT!NG, Al.TERATfON,WATER LOSS OR GAIN,CAVlNG,,LOST CORE,CEMENTING,ETC LENGTH REC O~F~~N (RQD) DEPTH (FT)ROCK TYPE OESCRJPTI ON :COLOR,TEXTURE.FOLIATION ,JOI NT1NG,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGTH I REG OF RUN (RQD)(q) Argi 11 ite Run 163 565.9 to 570.4 100 (100) 597.9 (4.22.7) 600 (424.2) Arqi 11 ite END OF BORING !Run 169192(92) 570 (403.0) 580 (410..1) 590 (417.1) Run 164 570.41 100 to (92) 575.4 Run 1651 575.4 100 to (94) 580.7 Run 16E 580.7-1 100 to (87) 583.7 Run 16 583.71 100 to (94) 588.5 Run 16 588.51 100 to (100) 592.6 Run 169 592.61 92 to (92) 597.9 1 ~~B ~~~~.~j ~V J, --,----1 ---~-l -~-----l "1 -,1 1 --]--]--~-]-1 '. Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG SUMMARY LOG Job No._P5700.05 Hole No.~ Sheet No._l~of _2_ REMARKS END OF BORING 597.9' • Shear/fracture zone, Shear. Shear/fracture zone Shear. Job No.P5700.05 Hole No._BH-5a Sheet No._2_of _2~_ Argi 11 ite ROCK TYPE Graywac ke ALASKA POWER AUTHORITY Project _Susitna Hydroelectric Proj_"e'oc,,-t__~ Site Oevi 1 C~",o"-r-"tl!h--!Bb!.Ja,-,n,-,,kcl)~ Client 600 500 480 460 420 I • I I -1--1(- 00 440 380 DEPTH (FT.) 360 I .11 I I 1 REMARKS Fracture zone, healed. • Fracture zone. -Shear/fracture zan Shear/fracture zan -Shear/fracture zan Shear/fracture zan ROCI<TYPE Graywacke Joints,slicken- sides. /-I i Phy11 iti c sheen. Client ALASKA POWER AUTHORITY Project Sus itna Hydroel ectri c Proj ect Site Devil Canyon (North Ba~ 40 60 340 I III 1I I I I 140 160 - 180 200 220 - 240--+798 260 28 - 300 C"~'Cl ,c"'<1 ,~",ccl __CCC'}c"c"]1 1 1 --l ]c~..1 ') ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT:ALASKA POWER AUTHORITY JOB NO"P5700,05 PROJECT,Susitna Hydroelectric Project HOLE NO,;BH-5b SITE:Devil Canyon (North Bank)SHEET NO.1 OF 7 CONT RACTlJR;Interstate Exploration Inc.DRILLING DATES'.June 19 TO June 26,1981 LOGGED BY'.K.J.White,M.P.Bruen DATE:July 1981 LATITUDE N3,222,964 ELEVATIONS.DATUM MSL,A.S.P.C.,Zone 4 DEPARTURE I616,63B GROUND SURFACE 976.6 AZII,lUTH 277°ROCK SURFACE 976.6 DIP 45°BOTTOM OF HOLE 835.0 WATER TABLE Depths measured along hole.True depths in (), All angles measured to the core axis. 19 REC (ROD) LENGTH Of RUN (FTJ 39.3 I 94to(88) 44.2 29.2 I 96 to (85) 34.0 21.5 I 100 to (79) 26.3 Run 13 34.0-1 100 36.7 (15) Run 15 Run 16 44.2 100 to (85) 48.1 Run 17 100 --10Q) Run 18 49.3 96 to (68) 52.1 Run 14 36.7-1 54 39.3 (13) Run 11 26.~93to(76) 29.2 r-~-- Run 12 rR-un 9 Run 10 JOB NO.P5700.05 SHEET NO.2 OF 7 HOLE NO.BH-5b DESCRIPTION:COLOR,n:XTURE,FOLIATION ,JOINTI NG ,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. 48.0-49.7 -Numerous quartz stringers,average 0.5 inch wide,folded and stretched,un- fractured.Comprise 30 to 40%of rock. 51.1-51.3 -Quartz stringers,0.3 inch to 1 inch side,folded,unfractured. 52.5-52.8 -Joints very close spaced,heavy iron oxide staining,probably open. 37.1 -Joint,40°,faint slickensides. 37.3-39.3 -Core loss of 1.6 feet.Core broken by drilling,pieces average 1 inch. 45.9 -Joint,50°,talc/chlorite coating. 40.3 -Bedding/foliation at 50°. 41.7-42.0 -Core broken by drilling,pieces 0.5 inch to 1 inch. ROCK TYPE Devil Canyon (North Bank) Argi 11 ite SITE PROJECT Susitna Hydroelectric Project CLIENT ALASKA POWER AUTHORITY DEPTH (FT.) 30 (21.2) 50 (35.4) 40 (28.3) 83 (0) % REC (RQO) 75 (41) 100 (57) 92 (24) 83 (11) 84 (54) 87 (55) 100 (28) RUN LENGTH Run 2 2.5 to 6.3 Run 3 Run 1 0.0- 2.5 Run 8 Run 5 Run 4 7.9 to 12.9 Run 6 14.7 to ~6.--1----1-Run 714.7- 19.4 CASING D1AI,lETER:NW (3,0")I.D. CORE DIAI,lETER,NQ (1.75")0.0. February 1,1982 Core badly broken inches. DESCRIPTION:COLOR ,TE:XTURE,FOLIATION,JOINTING,FRACTURING,f'AULTING I~N I WATER LOSS DR GAIN I CAVING,LOST CORE,CEWENTING.ETC. Medium to dark gray,fine grained meta- sedimentary rock.Very thi n beds coinci dent with weak to moderately developed foliation. Occasional very thin to thin beds of light gray,fine grained graywacke.Fresh,hard, and well indurated.Minor quartz veins and stringers.Sulphide mineralization,pre- dominantly pyrite,crystals up to 0.5 inch, some being replaced by quartz. Joints close to moderately close spaced with iron oxide staining near surface,and chlorite I I ----+ and carbonate at depth. 0.0-88.3 -Joints close spaced,iron oxide staining. 7.9-8.7 -Core broken ~y drilling,pieces less than or equal to 0.2 feet. 11.0 -Bedding foliation at 60°. 14.1-14.3 -Core broken by drilling. Diamond Core,Triple TubeSOIL ROCK Roel<TYPE Argi11 ite DEPTH (FT) LOCATION: DRILLING I,lETHOD, NOTES,~l 0.0 APPROVED,jvtb71{li~DATE: 10 (7.1) 19.5-20.6 -Some core loss. 20 J Iby dri lling,pieces up to 2 (14.1)I /l ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUffALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NElli YORK DRILLING REPORT CLIENT ALASKA POI,ER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHOR TTY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Susitna Hydroelectric Project SITE Devil Canyon (North Bank) HOLE NO.BH-5b SHEET NO.3 OF 7 SITE Devil Canyon (North Bank) HOLE NO.BH-5b SHEET No.4 OF 7 I r--- DEPTH (IT)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JOINTI NG,FRACTURING,FAULTI NG I ALTERATION,WATER LOSS OR GAl N,CAVING I LOST CORE,CEMENTI NG,ETC LI::NGTH OF RUN (FT) REC (ROD) DEPTH (FT)ROCI<T'!'PE DESCRIPTiON:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAuLTl NG, ALTERATION,WATER LOSS OR GAl N,CAVING,LOST caRE,CEMENTING,ETC LENGTH OF RUN (FT) REC (RQD) Run 33 92.3 I 100 to (68) 96.1 84.9-86.9 -Core loss of 0.8 feet.Core Run 30 76 broken by drillin9,pieces 0.5 inch to 2 84.8-(0) inches.Qh Q Run 31 88.3-90.7 -Shear/fracture zone,joints very 86.9-100 close spaced,joints at 25 0 to 70 0 ,chlorite 89.3 (67) and silt coatin9,some have slickensides.Run 32 88.3-102.0 -Joints close to very close spaced,89.3 100 chlorite coatin9.to (67) 92.3 Run 37 100(100 Run 38 100 100 Run 39 100 Run 40 108.0 99 to (99) 112.a Run 41 112.a I 95 to (83) 116.0 60 (42.4) 70 (49.5) 80 (56.6) Argi 11 ite 57.2-57.7 -Core broken by drillin9,pieces 1 inch to 2 inches. 58.2_58.7 -Quartz stringers,0.5 inch to 1 inch,folded,fractured but tight. 59.2-59.4 -Core broken by drilling,pieces 1 inch to 2 inches. 66.5 -Joint,40·,silt coating. 68.0 -Joint,50·,trace of silt. 69.6~69.8 -Joints very close spaced.Joint at 40 0 has slickensides. 71.5-72.2 -Core broken by drilling,pieces 1 inch to 2 inches,minor iron oxide staining. 80.0 -Bedding/foliation at 10 0 to 20 0 • 82.5e83.8 -Core broken by dri 11 i n9,pieces 0.5 inch to 2 inches.Jot nts at 20 0 to 60°, some have chlorite coating and slickensides. 83.0-83.3 -Cor~broken by drilling,pieces IIQ.V'::InO 1 in,..h Run 19 52.1 I 96to(61) 57.a RUi120 57.0-100 59.4 (54) Run 21 59.4 91 to (74) 62.9 Run 22 62.9 I 97 to (76) 66.6 Run 23 66.6 I 100 to (89) 69.3 Run 24 69.3-100 71.B (96) Run 25 71.8 98 to (71) 76.2 76.2-100 77 .9 (68) Run 27 71 Run 28 79.3 95 to (76) 83.0 Rui179T 100 83.0-1 (50) Q~Q 90 (63.6) 100 (70.7) 110 (77 .8) Argill i te 102.0 -Beddin9/foliation at 30 0 to 40 0 , 102.0-200.3 -Joints close to moderately close spaced,average 1 foot,trace of carbonate and chlorite coatin9' 109.7 -Shear,30 0 ,0.1 inch of breccia, slickensides,chlorite coating. 115.5 -Beddin9/foliation at 50 0 • 116.0 -Joint,50·,slickensides. Run 34 96.1 to 99.1 Run 35 99.1- 101.6 Run 36 101.6 to 105.1 100 (70) 100 (56) 97 (51) '4 J 1)n --1 --,--,~'~I ....]"'~l _._.)-~l -"""1 1 '''''~l "'1 ']1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 CLIENT ALAS KA POWER AUTHOR ITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project PROJECT Sus i tna Hydroe 1ect ri c Proj ect SITE Devil Canyon (North Bank) HOLE NO.BH-5b SHEET NO.5 OF 7 SITE Oevil Canyon (North Bank) HOLE NO.BH-5b SHEET NO.6 OF 7 DEPTH (FT)ROCK TYPE DESCRIPTION:COLOR,TE}/TURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER lOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC. LENGTH OF RUN (fT.) REe (ROD) DEPTj1 (FT.l ROCK TYPE DESCRIPTION;COLOR,T~)(TURE,FOUATION,JOINTING,FRACTURING,FAULTiNG, ALTERATION,WATER LoSS OR GAIN,CAVING,.LOST CORE,CEMENTING I ETC. LENGTH OF RUN (FT.) REe (RQD) 120 (84.9) Argi 11 ite ~un 421 94 116.0-(88) 119.3 IRun 4J 11 g.3 I 100 to (90) 123.7-124.1 -Core broken by drilling,pieces 1124.2 0.5 inch to 1 inch. 150 ~Argill ite (106·1)1 154.5 -Bedding/foliation at 50°. Run 50 149.3 I 99 to (96) 154.5 Run 51 130 (91.9) 126.7-127.6 -Numerous quartz stringers,less than 0.5 inch wide,folded,unfractured. Comprise approximately 25%of rock. 130.0 -Bedding/foliation at 40°to 50°. Run 44 124.2 to 129.3 Run 45 129.3 to 134.3 96 (90) 100 (88) 160 {113.1 158.0-159.3 -Shear/fracture zone,joints very close spaced.Shears at 30°and 50°,0.1 inch of breccia,clay,and chlorite,fractures at 40 0 •Core badly broken,pieces average 1 inch, many have slickensides and clay coating.Core loss of 0.5 feet. 159.3 -Quartz vein at 40 0 ,0.5 inch wide, unfractured,upper contact has slickensides, lower contact is tight. 162.9-163.9 -Core loss of 0.8 feet.Core broken by drilling,pieces average 1 inch. 154.5 to 159.3 Run 52 159.3 to 164.3 Run 53 100 (90) 80 (77) Run 46 134.3 to 139.3 100 (96) 170 (120.2 167.1-168.0 -Core loss of 0.6 feet.Core broken by drilling,pieces 0.5 inch to 1 inch. 164.3 I 94 to (90) 169.3 Run 54 Run 47 139.3 1100 to (86) 143.7 169.3 1100 to (86) 174.1 140 (99.0) Run 48 Run 49 145.2 to 149.3 90 (83) 95 (89) 180 {127 .3 174.0 -Bedding/foliation at 40°. 176.6-177.3 -Shear/fracture zone,joint spacing is very close.Joint at 40°has slickensides and chlorite coating.Other joints at 30°and 50°.Core loss of 0.3 feet. 178.8 -Joint,50 0 ,silt/clay coating.No evidence of shearing. 180.1-181.5 -Core broken by drilling,pieces 10.1 feet to 0.2 feet. Run 55 174.1 to 179.3 Run 56 100 (86) 100 (80) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT PROJECT Susitna Hydroelectric Project CLIENT SITE ALASKA POWER AUTHORITY Devil Canyon (North Bank) JOR NO.P5700.05 HOLE NO.BH-5b SHEET NO.7 OF 7 DEPTH (FT.) 190 (134.4 ROCK TYPE Argi 11 ite DESGRIPTI ON;GOI..DR,TEXTURE,FOUATION,JOlNiING,FRACTURING,FAULTI N~, ALTERATION,WATER LOSS OR GAIN,CAVI NG,LosT CORE,CEMENTING,ETC. 187.0-188.7 -Shear/fracture zone,joints very close spaced.Joints at 20 0 and 50'have slickensides and chlorite coating. 188.7 -Breccia is less than 0.1 inch wide. 194.7-195.3 -Shear/fracture zone,joints very close spaced,joints at 20°have slickensides, most have a trace of silt coating.Core loss of 0.2 feet. 199.9 -Shear,50 0 ,slickensides,less than 0.1 inch of gouge. LENGTH REC O~F~~N (ROD) Run 57 182.3 I 100 to (94) 187.3 Run 581 85 187.3-(62) 189.3 Run 59 189.3 1100 to (100) 192.7 Run 60 192.7 I 92 to (69) 195.3 Run 61 195.3 I 100 to (96) 200.3 200.3 1 I I I I (141.6 END OF BORING ~"~~~.~11 'I ~"i 11 d J )j 1 '°'1 F~-~C]--F-_c---'l ~l -'-'~-----I -"-1 ''I Fe ]'-1 --eel Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Job No.P5700.05 Hole No.~_b__ Sheet No._1_of 1 Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Oevi 1 Canyon (N,~O-,--rt-"-,h,---=,B-",an,,,k,-,)_ DEPTH (FT.I a 20 +--l±±-++++ 40 60 +-----+-H-+-+++_ 80 100 120 140 160 180 200 I I I~l ROCK TYPE Argill ite REMARKS ,-Shear/fracture. Shear/fracture zone -Shear/fracture. -Shear/fracture. Shear/fracture. END OF BORING 200.3' • -~"1 ··'··~l -~·l ·"'-1 1 -~-1 ..-..-.)'---J 1 ~·1 '·'1 ]~._)--.-) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFAlO t NEW YORK DRILLING REPORT LOCATION:LATITUDE N3,22l,70l ELEVATIONS;DATUM MSL,A.S.P.C.,Zone 4 DEPARTURE E6l6,133 GROUND SURFACE 1351.0 AZIMUTH 009 0 ROCK SURFACE 1343.2 DIP 45 0 BOTTOM OF HOLE 998.7 WATER TABLE NOTES:1)Depths measured along hole.True depths in (). 2)All an91es measured tD the core axis. CLIENT:ALASKA POWER AUTHORITY JOB NO.;P5700.05 PROJECT:Susitna Hydroelectric Project HOLE NO.;BH-7 SITE:Devil Canyon (South Bank)SHEET NO.1 OF 16 CONTRACTpR:Interstate Exploration Inc.DRILLING DATES,.May 18 TO May 31,1981 LOGGED BY·.R.R.Henschel DATE;July 1981 CASING DIAMETER:NW (3.0")I.D. CORE DIAMETER;NQ (1.75")0.0. CLIENT ALASKA POWER AUTHORITY 100 (41) LENGTH I RECOFRUN (FT/(ROD) 19.2- 22.2 Run 9 29.3 1100 to (83) 34.3 Run 8 25.4 to 29.3 HOLE NO.BH-7 SHEET NO.2 OF 16 JOB NO.P5700.05 OESCRIPTI ON:COLOR,TEl<TURE,FOLIATION,,,IOINTI NG,FRACTURING,FAULTl NG, ALTERATION,WATER LOSS OR GAIN,CAVI NG,.LOST CORE,CEMENTING,ETC. 11.0-12.7 -Rubble zone. 12.7-27.1 -Fracture zone,very closely spaced joints,70-80 0,paralleling bedding/foliation, and 0-150.Iron oxide staining.Core loss 1.4 feet. Devil Canyon (South Bank) Argi 11 ite/ Graywacke ROCK TYPE SITE PROJECT Sus itna Hydroel ectri c Proj ect DEPTH (FT.) 30 (21.2) % REC (RQO) OESeRI PTlON:COLOR ,TEXTURE,FoLIATiON.JOINTING,FRACTURING,FAULliNG,I RU" ALTERATION.WATER LOSS OR GAIN,CAVINg,LOST COR~,CEMENTING,ETC.LENGTH Casing Advancer Diamond Core -Triple Tube SOIL ROCK ROCK TYPE Overburden DRILLINGMETHOD: a DEPTH (H) 37.5-38.1 -Fracture zone,very closely spaced joints at 0_100 and 70-80 0 . Run 10 34.3 to 39.3 96 (76) 100 (%) 95 (90) 96 (73) Run 13 49.3 to 53.1 Run 11 39.3 to 44.9 Run 12 44.9 to 49.3 Rock description as above,with occasional thin beds of graywacke.Hard,fresh.Closely spaced joints.Numerous thin quartz veins. Argi 11 ite50 (35.4) 40 (28.3) Run 1 11.0 I 81to(0) 14.8 Run 2 14.8 I 80to(0) 19.2 -'J -,-----.l--c-- Run 3 I 100 (17) DATE;February 1,1982)A;7JILlZ f-----~TOP OF ROCK ----+---\-----1 Argillite/Medium to dark gray,very fine grained Graywacke argillite interbedded with light gray,fine grained graywacke in ver.y thin beds.Foliation parallels argillite bedding at 70 0 with gray- wacke bedding/foliation planar to highly deformed.Well indurated,tending to break along bedding.Generally fresh to slightly weathered with iron oxide staining and carbonate coating on joint surfaces.Numerous irregular fractures healed with carbonate. Occasional quartz veinlets.Jointin9 very closely to moderately closP1v <nerprl et 0_1"0. 55-65°,and 70-80 0. /' APPROVED; 20 (14.1) 10 (7.1) 11.a (7.7) / ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DR ILL IN G REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO P5700.05 CLIENT ALASKA PO.fER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-7 PROJECT Susitna Hydroelectric Project HOLE NO.BH-7 I ..SfTE Devil Canyon (South Bank)SHEET NO.3 OF 16 SITE Devil Canyon (South Bank)SHEET NO.4 OF 16 DEPTH (FT.)ROCf(TYPE DESCRIPTION :.COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTI NG , ALTERATlON,WATER lOSS OR GAIN 1 cAVI NG,'...OST CORE,CEMENTING,ETC. LENGTH OF RUN (FT) REO (RQD) DEFTH (FT]ROCK TYPE DESCRIPTION;COLOR,TEXTURE,fOLIATION,JOINTING,FRACTURING,fAULTING, ALTERATION,wATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC L.ENGTH OF RUN (FT.) REO (RQD) 59.0 (41.Z) '60 (42.4) Arq illite Quar.tz Oi orite Light gray,fine to medium grained dike material,very hard,sharp contacts.Joints moderately close to widely spaced at generally 10-200 and 70-80 0 • Run 14 IRun 15 54.1 to 59.0 Run 16 59.0 to 63.0 60 (0) 100 (94) 100 (70) 90 (63.6) Arg i 11 ite/ Graywacke 87.0-104.8 -Shear/fracture zone at very closely to closely spaced joints,highly chloritized breccia and 90uge,faint slicken- sides. 87.0-91 .0 ..Core loss 1.3 feet. 94.4-104.8 -Joints,70-80 0 paralleling bedding and 0-10 0 •Core loss 3.3 feet. IRun 24 84.1 to 89.1 IRun 25 89.1 to 94.3 94 (0) 81 (42) e---G~)IRun17 63.0 100 to (9Z) 67.7 Run 26 94.3 to 99.3 64 (0) 56 (0) 93 (9) 7T (0) Run 30 11 O.a to 115.0 lWn "'29 Run 2B 104.1 to 108.7 Run 27 99.3 I 54 to (0) 104.1 108.3-122.4 -Shear/fracture zone,very closely spaced joints.Extensive chloriti- zation on rock fragments and joints. 109.0-110.0 -Breccia/gouge. 110.0-113.0 -Joint,40 0 and 20 0 ,very closely spaced. 112.0-115.0 -Breccia/gouge. 110 (77 .8) .100 (70.Z) 85 (61 ) 100 (45) 100 (80) Run 21 74.9 to 78.9 Run 22 78.9 to 83.5 80 (56:6) 70. (49.5)Run 20 69.6 to ,13.3 h'.~-l74.9~51.8).,'Argill ite/Rock descri pti on as above. Graywacke '1 83.5-86.4 -Core broken by dri 11 i ng.Fragment 0.2,5 to 2 inches with chlorite coating,fn.~~ :possible fracture zone.~ Run 31 24 (0) '1 J 1 ~-1 "J -~c --J -}1 ""'J -1 ,")1 1 'J --]--'J ,~-C""J 'c_"1 .) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK BUFFALO I NEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project HOLE NO.BH-7 PROJECT Susitna Hydroelectric Project HOLE NO.BH-7 SITE Devil Canyon (South Bank)SHEET NO,5 OF 16 SITE Devil Canyon (South Bank)SHEET NO.6 OF 16 DEPTH lFTJ ROCK TYPE DESCRIPTION;COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG,~~N~JH I REC ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC.(FT.)N (RQn) DEPTH [1--'-.)ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURJNG,FAULTI NG I ALTERATION,WATER LOSS OR GAIN,CAVING"LOST CORE,CEMENTING,ETC. LENGTH DF RUN 1FT.) REC (RQO) '1 120,(84.8) Argill ite/ Graywacke Run 31 I 24 115.0 (0) 119.1 Run 32 6 (0) Run 33 120.2-69 122.4 (0) 150 (106.1) Graywacke Li~ht gray,fine grained metasedimentary rock,~+-----~ thickly bedded,disseminated sulphide minera1s.1 Run 45 149.6 1100 to (90) 154.5 Run 46 154.5 I 100 to (95) 159.6 -- Run 47 159.6 1 100to(95) 164.4 f---+--~ 174.4 1100 to (100) 179.5 130 (91.9) 140 (99.0) 125.9-130.7 -Shear/fracture zone,very closely to closely spaced joints at 0-100, 50 0 ,80-90 0 ,healed with carbonate, ch10ritized gouge. 125.9-126.1 -Breccia/gouge on joints at 80-90°,possible slickensides. 126.9-127.3 -Gouqe on fracture at 30°, 1/4 inch thick.tore loss 0.6 feet. 130.1 -Foliation well developed,30-35 0 • Phy11itic texture locally. 133.0-133.4 -Fracture zone,very closely spaced joints at 30-50°and 0-10°. 135.4 -Joint,60-70°,slickensides. Run 34 122.4 1100 to (27) 126.1 Run 35 126.1-86 128.2 (0) Run 36 90 (0) Run "37 130.1 89 to (58) 133.7 Run 38 133.7 I 100 to (99) 138.6 Run 39 138.6 100 to (83) 142.1 Run 40 100 (89) Run 41 75JQl Run 42 1OO(100 Run 43 100 47 Run 44 146.8-100 149.6 (100) 157.2 (111.1) 160 (113.0) 170 (120.2) 180 f-r 127 .3 ) Arqi11ite/ Graywacke Rock description as above.Fo1 i ation poorly to well developed,generally parallel to bedding.Fresh,hard. Joints closely to moderately closely spaced at 60-70°,80°,and 0-10 0 •Carbonate filling common. Run 48 164.4 to 169.4 Run 49 169.4 to 174.4 Run 50 Run 51 100 (91) 100 (100) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DR.ILLlNG REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO I NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA PO,fER AUTHORITY JOB NO.P5700.05 P.ROJECT Sus i tna Hydroel ectri c Proj e.ct P.ROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.8H-7 SHEET NO.7 OF 16 SITE Oevi1 Canyon (South Bank) HOLE NO.8H-7 SHEET NO,8 OF 16 DEPTH (FT.)RQCK TYPE OESCRIPTI ON:COLOR,TEXTURE., FOlfATION,JOINTING,FRACTURING,FAU LTI NG, ALTERATION,WATER LOSS OR GAIN,CAy.r NG',LOST CORE,CEMI':NTI NG l ETC. LENGTH OF RUN (FT.) AEC (ROD] DEPTH tfT.)ROCI<TYPE DESCRIPTION:COLOR,TEXT,UR"E,FOLIATION,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING,ETC LENGn OF RUN {FT.) REC (RQO) Argi n ite/ Graywacke Run 51 179.5 to 184.9 97 (93) Argi 11 He/ Graywacke I I IRun 59 213.7 1100 I to (90) 218.9 190 (134.3) 188.2-188.9 -8roken zone,low angle healed fractures rebroken by drilling. Run 52 184.9 1100 to (89) 188.8 Run 53 188.8 1100 to (86) 193.7 220 (155.54 Run 60 218.9 1100 to (90) 224.9 Run 57 203.7 \100 to (88) 208.7 200 (141.4) Run 54 193.7 to 198.9 Run 55 Run 56 200.1 to 203.7 96 (96) 83 (67) 100 (74) 230 (162.6) 226.6-227.2 -Ouartz vein,60-70°,part open contacts. 231.0-231.5 -Quartz vein,10-15°. 233.7-237.8? 245.0-248.0 J Bedding/foliation highly 248.8-251.2 distorted and irreqular. Numeroos quartz strin~ers.Hard':fresh. Run 61 224.9 to 229.5 Run 62 229.5 to 234.6 Run 63 234.6 to 239.6 98 (92) 100 (86) 98 (98) 2.:10 (148.5) 208.2 -Shear,0-10°,less than 1 inch of brecci a/gouge. Run 58 208.7 1100 to (93) 213.7 240 (169.7)Run 64 239.6 1100 to (100) 244.5 1'1 l ..l J n '1 B ~,~~,oj 'c._)-'~1 ,~-'-1 -~----1 -=-]rc-l ~--]--]""'--1 >-]-~--),--)".-"-1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK DRILLING REPORT ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO.NEW YORK DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-7 SHEET NO.9 OF 16 PROJECT Susitna Hydroelectric Project SITE Devil Canyon (South Bank) HOLE NO.BH-7 SHEET NO.10 OF 16 DEPTH I DEseRI PTI ON:COLOR,TEXTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG,LENCiTH REC DEPTH DESCRIPTION;COLOR,TEXTURE,FOLIATION ,JOI NTlNG,FRACTURING,FAULTI NG,LENGTH I REC ROCK TYPE OF RUN ROCK TYPE OF RUN (FTJ ALTERATION,WATER lOSS OR GAIN,CAVING,LOST COREl CEMENTING,ETC (FT.)(RQD)(FT.)ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING.ETC 1FT,)(ROD) Argill itel Run 65 Argill itel Run 72 Graywacke Graywacke 274.6- 244.5 100 279.6 to (92)280249.3 t'98Ol j Run 73 250 i I IRun 66 I 279.6 100 (176.8)to (98) 284.6 249.3 98 to (84) 254.3 254.1-254.3 -Fracture zone,very closely 1 Run 74 spaced joints at 0-10 0 ,45-50 0 ,and 80-90 0 •284.6 I 100Numerousthincontortedquartzstringersandb~67 to (96)veinlets,hard,tight.254.3 9~l I 289.6 to (86) 259.2 ["O205.0) 1 Run 75 260 1 1260.0 -Foliation well developed,40-50 0 ,IRun 68 I ~292.1-314.4 -Quartz stringers,closely to 289.6 I 100 (183.8)bedding 70-80 0 •259.2 100 moderately closely spaced,up to 3/8 inches to (98) to (94)thick.294.6 264.1 I I I I Run 76 Run 69 ~I 297.1 -Joint,80 0 ,chlorite,slickensides.1 294 . 6 1100to(100) 264.1 95 299.6 to (95)299.6 -Joint,75 0 ,faint slickensides. 267.9 300Run70100(21'-'lj Run 77(75)301.0-332.6 -Predominantly graywacke 270 1 I IRUn 71 composition,thick beds,joints closely 299.6 1 98 (190.9)spaced generally at 70-80 0 and 5-15 0 •to (62) 269.5 100 304.6 to (82) 274.6 I I I r--- Run 78 Run 72 I 100 I I I I 1 304 . 6 I 100 (84)to (89) 309.6 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUfFALO I HEW YORK BUFFALO I HEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT SUS itna Hydroel ectri c Proj ect HOLE NO.BH-7 PROJECT Susitna Hydroelectric Project HOLE NO.BH-7 SITE Devil Canyon (South Bank)SHEET NO.11 OF 16 SITE Devil Canyon (South Bank)SHEET NO.12 OF 16 343.0-344.9 -Shear/fracture zone,80°,very closely spaced fractures with some very thin !Run 86 breccia clay gouge coati n9,highly chloritized.342.1 ,91 to (88) 347.8 Run 91 364.6 1100 to (86) 369.6 Run 92 369.6 1100 to (100) 374.6 Run 87 347.8 100 to (100) 352.9 Run 88 100 (100) Run 89 354.9 100 to (83) 359.9 Run 90 359.9 1100 to (59) 364.6 DEF'TH I DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOI,NTI NG,FRACTURING,FAULTI NG,LENGTH REe ROCI(TYPE OF RUN (FTJ ALTERATION,WATER LOSS OR GAl N,CAVI NG,LOST CORE,CEMENTI NG ,ETC.(FT.)(flQO) 310 l Argi 11 ite/ (219.2)Graywacke IRun 79 309.6 ,100 to (78) 314.6 --- Run 80 314.6 I 100 to (96) I 319.6 I j 320 (226.2fl I IRun 81 319.6 I 100 to (92) 324.7 326.7-326.9 -Fracture zone,very closely Run 82 spaced joints at 0-10°,50-60°,and 80-90°,324.7 I 100chloritized.to (80) 327.5-327.8 -Shear zone,70-80°,several 329.6 chloritized planes. 330 l I 330.6-332.6 -Shear/fracture zone,very IRun 83(233.3)closely spaced joints at 0-10°and 70-80°,329.6 87highlychloritized,quartz and carbonate to (20)coating.Core loss 0.4 feet.332.6 Run 84 332.6 100 to (84) 337.7 Run 85 337.7 I 100 340 rt I I to (91 ) (240.4)342.1 DEPTH 1FT) 350 (247.5) 360 (254.5) 370 (261.6) ROCI(TYPE Argi 11 ite/ Graywacke DESCRIPTION:COLOR,TEXTURE,FOLIATION ,JOI NTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC. 358.4-363.0 -Joint,0_5°,slick,planar, hi9hly chloritized,tight,offset by 3/16 inches. 358.2-372.8 -Predominantly graywacke,fine to medium 9rained. LtNGTH OF RUN (FT) Run 85 REC (RQD) '\1 '1 }.'~11 ]ffl t 'ci :J :J ')'~~l c'~']~'-'--"l .,e",'1 ~--"'l -'1 --]---~___e']-)1 ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK BUFFALO,NEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO_P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO_P5700.05 PROJECT Susitna Hydroel ectri c Proj ect HOLE NO.BH-7 PROJECT Susitna Hydroelectric Project HOLE NO BH-7 SITE Devil Canyon (South Bank)SHEET NO_13 OF 16 SITE Devil Canyon (South Bank)SHEET NO_14 OF 16 DEPTH (FT.)ROCI(TYPE ~:COLOR,TEXTURE,FOLIATION,JOINTING,FRACTURING,FAULTING, ALTERATION,WATER LOSS OR GAIN,CAVING I LOST CORE,CEMENTING I ETC LENGTH OF RUN 1FT.) REG (RQCl) DEPTH (FTJ ROC/<TYPE DESCRIPTION:COLOR,TExTURE,FOLIATION ,JOINTING,FRACTURING,FAULTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING I ETC IF::NGTH OF RUN (FT.) REG [ROD) IRun 100 403.8 98 to (98) 409.2 --- Run 101 409.2 I 98 to (91) 414.5, IRun 102 414.5 100 to (92) 419.6 un 103 419.6 100 to (88) 424.7 IRun 104 424.71 100 to (76) 429.6 \----+--- IRun 105 414.0-414.5 -Fracture zone,very closely spaced joints and fractures at 100 and 20°. 418.2-420.8 -Argillaceous zone with weakly developed foliation at 50°. 427.0 -Shear,1.8 inch wide,tight, chloritized,sulphides. 427.5-427.6 L Q .428.6-428.8 J uartz velns. 429.6-432.8 -Argillaceous zone with bedding at 60-65°,phyllitic locally,closely spaced joints. 4~3.4-4~6.6 -Quartz intrusions 70%o!core.~429.6 I 100 'Hlghly lrregular contorted quartz strlngers,t (98) pods and veinlets destroying original structur 43~6 of rock.Zones range from 1 inch to 8 inches . thick. Graywacke 410 (289.9) 430 (304.0) 100 (94) 100 (98) 100 (100) --\----- Run 95 10062) Run 96 385.9 100 I R 420 to (82)(296.9) 390.5 -~ Run 97 390.5 1 100 to (76) 393.8 Run 98 393.8 to 398.8 Run 94 379.6 to 384.6 l---,I ,JRun99 398.8 94 to (86) 403.8 Light to medium brownish gray metasedimentary R n 93 rock with subrounded to elongate quartz grains.u Bonded locally with dark gray argillaceous 374.6 beds.Hard to very hard.Foliation poorly to developed except in argillaceous layers,379.6 generally at 50°.Bedding,70-85 0,average 80°.Minor thin irregular quartz stringers. Joints moderately closely to widely spaced a-laC and 70-80°. 400 (282.8) 390 (275.7) 380 (268.7) Argi 11 i tel 374.6-1 Graywacke I -+--+---t(264.8)~Graywacke 404.0-407.7 -Foliation weakly developed at 50-60°.Run 10 IRun 106 434.6-1 100 437.7 (57) ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS ACRES AMERICAN INCORPORATED -CONSULTING ENGINEERS BUFFALO,NEW YORK BUFFALO,NEW YORK DRILLING REPORT DRILLING REPORT CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 CLIENT ALASKA POWER AUTHORITY JOB NO.P5700.05 PROJECT Susitna Hydroelectric Project 1l0LE NO.BH-7 PROJECT Susitna Hydroelectric Project ~OLE NO.BH-7 SITE Oevil Canyon (South Bank)SHEET NO.15 OF 16 SITE Devil Canyon (South Bank)SHEET NO.16 OF 16 DEPTH (FT.1 ROCK TYPE DESCRIPTION;COLOR,TEXTURE,FOLIATION,JOiNTING,FRACTURING,FAULTING, A.LTERAlION,WATER LOSS OR GAIN,CAVING,LOST CORE,CEMENTING 1 ETC LENGTH OF RUN IFTI REC {RQDl DEPTH t FT.\ROCK TYPE DESCRIPTION:COLOR,TEXTURE,FOLIATION,JO/NT1NG,FRACTURING,FAU LTI NG, ALTERATION,WATER LOSS OR GAIN,CAVING,LOST CORE,CeMENTING 1 ETC LENGTH OF RUN (FT,) REC (RQD) 440 (311.1) Graywacke Run 107 437.7 1100 to (88) 444.7 470 (332.3) Graywacke Run 114 467.61 100 to (84) 472.6 Run 115 472.61 100 to (100) 477 .8 Run 108 444.71 100 to (90)I I480449.7 (339.4) 450 i I 450.6-456.7 -Argi 11 aceous zone,hard,1-I --- (318.2)brittle,weakly developed foliation at 40-45°.Run 109 Joints generally 50°and 70-80 0 • 449.7 1100 to (98) 454.8 ~- Run 11 0 457.9-460.7 -Quartz vein,massive,hard,454.8 100SUlphidemineralization.to (73) I I490459.7 (346.4) I 461.7-462.7 -Core loss 0.4 feet. 460 ~R:m 111 (325.2)459.7-80 461.7 (45) Run 0 463.0 -Shear zone,6So,1/4 inch wide (0\ breccia/gouge,healed with carbonate, chloritized,intact but friable,slickensi des.\Run 113 462.71 100 to (98)I r 498.3467.6 (352.3)1 500 Run 114 1 I I (353.5 \ Run 116 479.5-480.9 -.Shear/fracture zone,15-20°,VerYl477.8 100 closely spaced joints and fractures,some to (64) breccia/gouge,chloritized,some carbonate..~48~0~.~3~___ Run 117 480.3/100 to (90) 485.6 Run 1181 485.6 100 488.7-490.5 -Foliation highly contorted and to (71) folded quartz stringers.489.7 1 Run 11 'l 489.7 100 to (96) 494.7 Run 12 494.7 100 to (100) 498.3 I END OF BORING ]11 lj ::J .~~~S t1 ,jgj Cl "~".~"C]~]~]1 -1 --")."..'-I "'.'} Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Project~sjJna Hydroel ectri c Proj ect Site Devil Canyon (South Bank) Job No.P5700.05 Hole No .._~B,,-H,,---,-7 _ Sheet No._1_of _2_ Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Devil Canyon (South Bank) Job No.P5700.05 Hole No.BH-~7 __ Sheet No.__2_of _2_ ~~~~I ~~~\CORE RECOVERY % ROD %ROCK TYPE REMARKS TOP OF ROCK 11.0' Fracture zone. Shear/fracture zone Shear/fracture zone Shear/fracture zone, Shear. Quartz stringers. Quartz stringers. Shear/fracture zonel Shear/fracture zan [iii] DEPTH (FT.1 360 380 400 420 440 460- 480 500 ROCK TYPE Argi 11 ite/ "I Graywacke Graywacke REMARKS Shear. Quartz veins. Shear. Shear/fracture zone END OF BORING 498.3' • -71 -1 -C--~-l -~~~~~~-1 1 ~'>~])-'1 -1 '--'1 1 "'-] Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York --.JH+++++++--++-+++++-+-1--++-4 Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.USBR DH-5 Site.Devil Canyon (South Bank)Sheet No._1_of __1_ PERMEABILITY CORE RECOVERY RQD NUMBER OF DEPTH ELEV.(Kl em/uc.%%JOINTS PER ROCK TYPE REMARKS(FT.)[FT.)10FT 10_6 10-4 iO-2 20 40 60 80 20 40 £0 BO 5 10 15 20 U 1374 Overburden 20 40 f---1324 --lOP OF ROCK 55.5'-- 60 ..Graywacke ]Fracture zone . f-----:.-=180 END OF BORING 100 4274 86.2' f---f--- i- I---1-----I- f------ f------ I-I-. f-----1---_.--- c--- c----' m[i] REMARKS Zone permeated by quartz stringers. Fracture zone. Fracture zone. Fractures,open. Quartz vein. Fracture zone. Fracture zone. END OF BORING 118.2' Job No.P5700.05 Hole No.USBR DH-l Sheet No.,_1_of _1_ ROCK TYPE NUMBER OF ,JOINTS PER 10FT. 5 ,'0 15 20 Lli I I I I I I Argillite SUMMARY LOG Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site DeviLJ:Q1lJIQ!LJSouth Bank) 20 40 60 80' DEPTH (fT.) 120 100 I-I'+++++-++++-++++-+-+-1 I--+---++++++.f.- Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client_ALASKA PQWER~THORlTY Job No.~700.05 __ Project~~droelectri c Proje~______Hole No.USBR OH-6 Site __Dev i 1 CaJ:l.lQlL1South Bank~_Sheet No._1_of---.l_ DEPTF [LEV,PERMEABIUTY CORE RECOVERY ROD NUMBER OF ll<J em/nt.%%JOINTS PER REMARKS(FT.)(FT.)10FT.ROCK TYPE 10-6 '0 <1 10-2 20 40 60 80 20 40 60 so 5 10 15 20 a 1370 I Overburden ------'- 20 '--f---f-f- ---- 40 ---e---f-----1----l-f--- I--320 ~_'_~L-_f---f-f--- 60 - -----f-I--f--- 80 --j ---L-TOP OF ROCK 87.5'-- No Test .....!Graywacke p Faint slickensides.100 1270 -~t.a-,-f-f---I-- -. -----END OF BORING,...I, 120 1250 r-il j 1---tr- -f---e--107.3' ---Ii-------- '---ll-ft l j -t .~---+-f- --- .11'r'---i-f-- --~'--- -..--- j I til Jlt .,---1--I-- --\Ilj~j-,----I--f----+f---L- f-----I--_---f----f-f-- 1-----~JjJ -~---i---f----f--- I----L-_-----f---f--- 1-------f f---c__ r---- f,I - --IT - ------+----_.---------------j -----"----j- --~---------I --, -,-- I "= --~f---~- --------- ----- ---.,--~ --+-+- -------"-'-f--------c • Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No .P5700.05.----,----- Project Susitna Hydroelectric Proiect ----Hole NO.__USBR DH~ Site _------.!l.e'Lil Canyon Sheet No ...--L of--.L- PERMEABILITY CORE RECOVERY ROD NUMBER OF DEPTH ELEY.(K)em/ue.%%JOINTS PER ROCK TYPE REMARKS(FT.)\FT,)10FT 10-6 10-<1 10-2 20 40 60 eo 20 40 60 80 5 10 15 20 0 3/b Overburden 20 I-------f--TOP OF ROCK 33.9' 40 ~--L_'--Argi 11 ite f---Missing Core I-- 60-END OF BORING-t --I--c.-I--59.5' ._-I---- 1--- I-- f----- [--I-I-I- n-f---- - - - - 1----- it f-- f-----t f------- f-ij--I--....+-f---- r-f-f---f------1---_1_,- --[--f-------- I--i----- I--f----f-~1----f-f---f----- 1--1-----II ~~t ----I---1---- j 1-- - 1--.l-.l- I----- 1---.-[----I-I- i---- , I-f----f----t I-I--f--- - i-- ~i 1 ']-7~1 -"--,---~'-~)A ___']-'-"'],-C',_--'l --']-'-'1 J ]~'-'j -,-.----1 -~-l ----'J -'o] Acres American Incorporated -Consulting Engineers Buffalo,New York Client ALASKA POWER AUTHORITY Project Susitna Hydroel ectri c Pro j ect Site Devil Canyon (South..B,"'allnk"')I--_ Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client __ALASKA POWER AUTHORITY Job No.P5700 05 Project Susitna Hydroelectric Project Hole No.USBR DH-9 Site Devi_l Canyon (South Bank)Sheet No._1_of ~_1_ ELEV,I PER"EABILITY CORE RECOVERY RQD NUMBER Of DEPTH JOINTS PER (FT.)(FT.)(I(J cmhec.%%10FT ROel<TYPE REMARKS 10.6 lOA 10-2 20 40 60 60 20 40 60 80 5'10 15 20 0 1424 Graywacke 20 P Fracture zone. 40 --1389 p Fracture zone. 60 '---- f---,----- 80 r---•Fracture zone, END OF BORING 100 1318 87,0' ,-----' f-----1------ f---f-- - '----L-_ • REMARKS END OF BORING 150.5 ' Fracture zone. Breccia zone, healed. Numerous quartz stringers and blebs Job No.P5700.05 Hole No.USBR OH-8 Sheet No....l-of ~ ROCK TyPE • NUMBER Of JOINTS PER 10FT. 5 10 15 20 ,I I I I I I Arg ill ite ~Fracture zone. 'T I I I I I I +--I Graywacke SUMMARY LOG o 20 60 40 80 160 DEPTH (FT.) 140 100 120 Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG Client AI ASKA POWER AUTHORITY Project Sus i tna f'ydroe 1ectri c Proj ect Site Devil Canyon (South Bank)_ Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project _______Hole No.USBR DH-1'1 Site Devil Conyon (South Bank)Sheet No._1__of _1__1''''''''_NUMBER OF DEPTH ~;~.~.(K)tmlsK %%JOI NTS PER ROCK TYPE REMARKS{FT.l 10FT. 10-6 10-4 10_2 20 40 60 00 20 40 60 so 5 10 I~ZO 0 "II Argillite 20 ~...... 40 867 END OF BORING --f--f--31.2' --- ---- --~~ ~--~ote:Borehole -day1 ig hted. ------ ~1- -----f--f-f--f-- ~----,----f--f--f- ------'__C,__ ~--,'--~-r-+-' -----' ~-+-- c---~- ---- C-----'-----t- --------f--f--f--f- 1 '--------,---- - 1 f-f-f- '-f-- -,-~ • REMARKS • END OF BORING 122.7' Fracture zone. Job No.J051Q~ Hole No.__USBR DH-10 Sheet No.__1_of _1_ ROCK TYPE I I I I I Graywacke NUMBER OF JOI NTS PER lOfT. 5 10 15 20 D 11425 20 ~E~T~I f;~.~· 40 -t1386 60 - 80 ~1;~:120 1315-i H 140 It ~HttlttlJI ~~ "C~"]""=-1 ,c~l "]"]1 -"-j ""'-'],"'1 1 --1 ,'---J Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.USBR DH-11 A Site __~Canyon (South Bank)Sheet No._1_of _1__ 1 """'."J•• NUMBER Of OEPTH ~~~.~.(K)cmflClc.%'Yo".JOINTS PER ROCK TYPE REMARKS(FT.)10FT. ~:jf ~.,".....S 10 15 20 0 Argi 11 ite 20 f---.END OF BORING4086629.8 ' I---f-- I---- c-- ,-~tI----- - ~-----c--c-- c--I- -- f--- ---- --- • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.USBR DH-11 B Site Devil Canyon (South Bank)Sheet No._1_of _1_ ~;;I~"'7:;~"_NUMBER OF DEPTH JOINTS PER ROCk:TYPE FlEMARKS(FT.)10FT. 10 6 OA 10-2 20 40 60 BO 20 40 60 eo 5 10 15 20 0 ~':-Ar9i 11 ite rFracture zone. 20- 40-863 END OF BORING 33.9' c---- Note:Borehole I-----dayl ighted in the river - f----c-----' I------ - • Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA PO'lER AUTHORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.USBR DH-12 Site -.nevil Canyon (Sollth Bank)Sheet No.----L of ~ DEPTH PERMEABILITY CORE RECOVERY ROO N.UM6EFl OF ELEV.(I()em/aee.%%.101 NT5 PER ROCI(REMARKS(FT.)(FT.)10FT.'TYPE 10.6 10.4 lO_l 20 40 60 60 20 40 60 80 5101520 0 896 Argi 11 ite 20 '"'Graywacke +' '"CO> 40 ---+' -B61 "I. Q)I I I I I I I60u -----:E---Core Missing "I 80 '--_If> "---~+:-Graywacke 100 825 ,-- I--,11.120 1--- I----1-------f--+-END OF BORING 140 797 ,-j-I-127 oS' 1-----1---c-~-j.-f--I-f- I----I-f-----I-- --f--j-,--r-I-- --f-f--r-I--I- --+- --+-f-- --- -f-I--- f------~--- --I--.-f--- - -- -- • REMARKS • Sandy interbeds. END OF BORING 151.1 ' Fracture zone. Job No.P5700.05 Hole No.USBR DH-1'1 C Sheet No._1 _of _1 _ ROC I(TYPE LOG ~---I---I---I---Ar gill i te r-l I~_-Fracture zone. r~l-J--LJ Graywacke I SUMMARY ALASKA POWER AUTHO.~R~IT~Y .Client Project.Susitna Hydroelectric Project Site ~il Canyon---"(S~D~u,-"t,-,h~B",a,,,n...,k'.L)_ 20 40 60 BO DEPTH (fT.) 120 160 100 140 1-1-~J ')1 '1 -~-'"---'I .c ___)'---1 e_'c_]1 .'.,'-'J -'J ..,')"~---J oJ ]--1 -)~J Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American I ncorpora ted -Consulting Eng;neers Buffalo,New York SUMMARY LOG Client AI ASKA PQWE~THORITY Job No.P5700.05 Project Susitna Hydroelectric Project Hole No.USBR DH-13 Site Devil Canyon (North Bank)Sheet No._1_of _1_ ELEV,'"RMEABILITY CORE RECO\lEfilY ROD NUMBER OF DEPTH JOINTS PER tFT.I (FT.)(K)em/llc,%%10FT.ROCK TYPL=:REMARKS 10-6 10_4 10,2 20 40 60 eo 20 40 60 80 5 10 15 20 U ~I~-Graywacke 20 Argi 11 ite 40 -Graywackec----877 I ICor e MiSsi~960- i L...-..~--Neg~'g~bl 80 ~=... I I I J""~-PBreccia,healed. 100 841 No -p Breccia,healed. Test II 120 __D a,....~ ~--.!ir ~ 8L140 END OF BORING 137.0' ~-----m f-- I---"-f--_c f--- ~- I---_c_ ,--.. r--- '-I-c - - • Numerous thin quartz veins. • REMARKS END OF BORING 149.7' Job No.P5700.05 Hole No.USBR DH-12A Sheet No.-.-l-of ..-L .'lOCK TYPE NUMBER OF JOINTS PER 10FT 5 10 15 20 +-++-++-+-+--1 Arg i 11 i te SUMMARY LOG ALASKA POWER AUTHOR~IT~Y ___ Susitna Hydroelectric Project Devil Canyon (South Bank) Client Project Site 40 Graywacke Arg illite 120 14D 160 Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No.P5700.05 Project SusitnQ Hydroelectric Project-----Hole No._~R DH-13A Site Oevil Canyon (North B~_____Sheet No._1_of _1 _ DEPTH ELEY PERMEABILITY ICORE RECOVERY ROD NUMBER OF IK)crr!~ec."/0 %JOlNTS PER ROCK TYPE REMARKS(FT.)(FT.)Ion 10-6 iOA 10-2 40 60 80 20 40 60 BO 5 10 15 20 0 91<'I I 1_"'"Graywacke 1IlI-Argillite20f-----+No I -l Test '-GraywackeDatap40'- --88<' 60 ---I"If---~----nDike,felsic,minor shearing at contact 80 864 I END OF BORING -~~.-80.7 ' c-----1--f---~--- 1---- ------f--~f---j--r--f-- f-------f---~f-c--I-c-- c----f--c---1+- 1------_c_r---'--f-+- 1----------- ~-------I+-~ f------I-~'--I-r- - f---- --f---f----f-- -f----- --I--- f---.-- --I--- --I--,--- f----I--1-1- I I i-- liiJ Acres American Incorporated -Consulting Engi neers Buffalo,New York SUMMARY LOG Client ALASKA POWER AUTHORITY Job No._P5700.05 Project Susitna Hydroelectric Project Hole No.USBR DH-14 Site Devi~n (North BallkL...-Sheet No._1_of __1_ I PERMEABILITY COA E RECOVERY RQD NUMBER OF DEPTH E..EV.%.;OINTS PER (FT.)1FT.)(I()em/ue.%10FT ROCK TYPE REMARKS 10.6 10·-1 10-2 :<0 40 lOU tlO 20 40 60 80 5 10 15 20 0 '"!!II Arg illite I-Fracture zone. 20 -No Flovi TL..-I-1------ 40 -868 fIIi'lIIIlIIIII I-f---l-I-- I---- 60 ~-i--END OF BORING 50.0' L..------i--f---r-I--f-- --f--- I-----Note:Borehole --'---------f--daylighted in the river. ------I--f-- ------- -------1--1--I--f----~ -----~-f---f--I--- -.- I -1--1-- -------r ----------,-f--I--I--- ---- j ---J---I-----f-f--f-----f---,---r- ------~--- I ----I-1--- -----'-----f+- --------'--I-- -------f--I--I--f-- ----------- ----- --- ----------I--f--- ------j --~- - -.....,~- • ~'1 -'-1 '-1 .---1 -----]~--~·-1 --~l ')---I ---~--1 ''J -]---1 ·---·-~1 J Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York Acres American Incorporated -Consulting Engineers Buffalo,New York SUMMARY LOG SUMMARY LOG REMARI<S Fracture zone. -Joint,silt coating Job No.P5700.05 Hole No.USBR DH-14B Sheet No._1~of _1_ ROCI(TYPE eND OF BORING 146.2 ' I.IUMBER OF JOiNTS PER 10FT. 5101520 1IIIIIl----l------l---++--l Arg i 11 it e .-Joint,slickensides~6Fracture zone. Client ALASKA POWER AUTHORIT-'-Y _ Project Sus itna Hydroe 1ectri c Proj ect Site -----.DeviL.CiillY.oJl.J1Lort h Jl..iillk.l 60 20 BO 40 o DEPTH (FT.) 160 100 140 120 Fracture zone. END OF BORING 130.4' REMARKS Interbeds of graywacke. Fracture zone, quartz healed. JobNo.~~_ Hole No.USBR DH-14A Sheet No._1_of _1_ ROCK TYPE ~I I I I I Argillite Client ALASKA POWER AUTHORITY Project Susitna Hydroelectric Project Site Devil Cil.!l.YQiLjNort'!.'h---!B""a",n",kL)_ o 2" 40 60 80 100 120 140 +921 DEPTH (fT.) •• Acres American I ncorpora ted -Consulting Engi neers Buffalo,New York SUMMARY LOG CI ient __ALASKILEilllEJLlIUTHORITY Job No.__£--'5700.OS __ Project -----.S.llsitlliLHydroe1 ectri c Proj ect _______Hole No._JilllB_DH-14C Site Oevil....ill.Yon (North Bank)-----Sheet No._1_of _1__ OEPTH ElEV."R"EABILITY ICOR'R'COV'RY ROD NUMBER OF (K)ern/Bet.%%JOINTS PER (FT.)(fT.)10FT.ROCK "'YPE REMARKS 1:)-6 10-4 10_7 ~O "!O 60 60 20 40 bO 80 '5 10 15 20 U YU,J I Graywac ke 20 --- ----I- Fracture zone. 40 -- -862 !!!-60 f--------- --I---!- 80 tNO OF 80RING 100 821 I--- 82.2' - ------- ----"-----1--1- -------f--- -f--------+--~r-----f--I- ------c-_~- ---f- I -- -----f-- --I- ----- -t J __-L. --~-i-f----C-L.1---1-1- -----f--~f-- f------- I------------- ---- ---------~--- ,I I --- - I -.• 1 1 r-t i '-' '..- - ,-, APPENDIX D WATANA WATER PRESSURE TESTING DETAILS J --1 -1 ---j --1 ,"_oJ ]~-~-1 ~--l 1 1 -)1 c--l --J ]0·0'J SURGE TANK FLOWMETER PANEL FLEXIBLE HOSE TO WATER SOURCE WATER SOURCE FLEXIBLE HOSE BY-PASS VALVE FILTER<:::;LOW -CONTROL VALVES FLEXIBLE HOSE PRESSURE GAUGE 0-300 psi AW DRILL RODS INFLATiON LINE INFLATABLE PACKERS SCHEMATIC VIEW OF WATER PRESSURE TEST ASSEMBLY iii] - BH-l (continued) Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability (feet)(feet)(psi)(min)(gpm)(em/sec) 279.0 290.0 140-142 6 1.25 1.42 x 10-5 300.0 8 3.0 4 -6180.0 90 6.8 x 10 200.0 300.0 100 8 2.3 5.64 x 10-6 220.0 300.0 110 8 2.15 -65.91 x 10 240.0 300.0 120 8 2.3 -67.63 x 10 260.0 300.0 8 2.2 -61309.43 x 10 138 8 2.3 -5280.0 300.0 1.65 x 10 NOTE:Section 180 ft to 300 ft depth,tests performed using single packer only. .... SUMMARY OF WATER PRESSURE TEST RESULTS Borehole Number BH-2------------ 1838.8 feet 1768.8 feet 55 0 Location Watana Ground Surface Elevation-------- Static Water Level ---~..=....:.-=---:.-=-=--=----- Dip of Hole -------------- Sti ckup O--:f-=e..;;..e..;;..t _ I""'"Depth Tested Gauge Duration Flow Coefficient off From To Pressure of Test Rate Permeabil ity (feet)(feet)(psi)(minutes)(gpm)(em/sec) r 23.9 40 20 20 .32 1.44 x 10-5 38.9 55 26 10 .18 5.96 x 10-6 53.9 70 30 20 .42 to 2.5 1.14 x -5 10-510to6.8 x ,.... I r r ,.... I""'" ! SUMMARY OF WATER PRESSURE TEST RESULTS """Borehole Number BH-3I Location Watana 1- Ground Surface Elevation 2150.7 ft. Static Water Level 2150.7 ft. Dip of Hole 55°..... [Stickup 4.6 ft. I"""Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability (feet)(feet)(psi)(min)(gpm)(em/sec) 34 45 19-20 8 0.07 6.21 x 10-6 I 40 51 23 5 O.17 1.30 x 10-5 [ 1.32 x 10-550612740.20 .....60 71 31 4 0.02 1.16 x 10-6 [ 70 81 35 5 3.10 1.60 x 10-4 *80 91 39 2 2.90 1.35 x 10-4 i"""90 101 43 2.54 x 10-650.06 100 111 47-49 5 0.08 3.05 x 10-6 *110 121 No Test 120 131 54 10 0.32 1.09 x 10-5-130 141 58 9 0.29 9.23 x 10-6I' 140 151 64 9 0.03 9.53 x 10-7 150 161 67 11 0.05 1.38 x 10-6 160 171 72 11 0.03 -78.00 x 10 170 181 76 10 0.08 1.92 x 10-6 180 191 80 16 0.07 1.63 x 10-6 190 201 84 12 0.04 8.87 x 10-7 r"'"200 211 88 12 0.04 8.65 x 10-7 210 221 92 10 0.06 1.21 x 10-6 r-220 231 96 8 0.06 1.16 x 10-6 , 230 241 100 8 0.20 3.74 x 10-6 .....240 251 104 10 0.48 8.63 10-6 I 2.95 x 10-6250261108100.17 ~*Packers did not completely seal. p""i BH-3 (continued) Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability (feet)(feet)(ps i )(min)(gpm)(em/sec) 260 271 112 8 0.16 2.66 x 10-6 270 281 117 12 0.25 4.01 x 10-6 280 291 121 8 0.15 2.33 x 10-6 290 301 125 8 0.17 2.54 x 10-6 630031112980.12 1.75 x 10- 310 321 133 6 0.16 2.26 x 10-6 320 331 137 6 0.22 3.02 x 10-6 330 341 141 6 0.22 2.93 x 10-6 340 351 145 6 0.36 4.67 x 10-6 f'~·"l 350 361 149 6 0.46 5.81 x 10-6 360 371 153 6 0.70 8.61 x 10-6 370 381 158 8 0.82 9.78 x 10-6 380 391 162 5 0.40 4.65 x 10-6 ~' 390 401 166 5 0.47 5.34 x 10-6 400 411 170 5 0.98 1.09 x 10-5 410 421 150 4 1.02 1.28 x 10-5 420 431 178 5 2.8 2.97 x 10-5 430 441 162 5 1.0 1.16 x 10-5 440 451 187 12 2.2 2.22 x 10-5 450 461 193 12 1.8 1.76xl0-5 ,~' 460 471 195 6 2.2 2.13 x 10-5 471 520 No Test 520 531 215 8 0.59 5.19xl0-6 *530 541 190-200 6 3.22 -53.12xl0 *540 551 100 8 0.95 1.78 x 10-5 *550 561 180 10 0.59 6.18 x 10-6 560 571 235 8 0.41 3.29 x 10-6 "~l 570 581 240 8 0.22 1.73xl0-6 580 591 200-210 10 6.07 -55.59 x 10 p"", *590 601 200 10 6.87 6.49 x 10-5 600 611 224 10 0.09 7.60 x 10-5 610 620 200 10 0.41 -63.87 x 10 *Packers did not completely seal.,=,,0'"·1 ,- BH-3 (continued) ~ Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability r""(feet)(feet)(psi)(min)(gpm)(em/sec) 620 631 220 10 0.15 1.29 x 10-6 *630 641 210 6 1.53 -5 (""I 1.38 x 10 640 651 240-250 8 5.05 3.90 x 10-5 *650 661 220-235 8 3.63 3.02 x 10-5 660 671 200-245 10 0.47 -63.90 x-10 670 681 200 10 0.61 -65.76 x 10 I"""680 691 200 12 0.94 8.88 x 10-6 690 701 220 10 0.23 -61.98 x 10 r--700 711 225 8 0.24 -62.02 x 10 710 721 225 8 0.24 2.02 x 10-6 720 731 230 8 0.23 -6 r""1.89 x 10 730 741 235 8 0.24 1 .93 x 10-6 740 751 240 6 0.25 -61.97 x 10,....,-675076124080.25 1.97 x 10 760 7Tl 245 6 0.24 -61.85 x 10 r'"770 781 250 8 2.35 -51.78 x 10 780 781 250 6 2.50 -51.89 x 10 790 801 250 8 2.23 -5I"""1.69 x 10 800 811 250 6 1.42 -51.07 x 10 821 250 8 1.60 -5 I""'"810 1.21 x 10 820 831 240 6 4.17 3.29 x 10-5 830 841 245 8 1.29 9.96 x 10-6 r--684085125080.61 4.62 x 10 850 861 160-165 8 0.57 -66.63 x 10 r-160 8 0.89 -58608711.05 x 10 881 210 10 0.98 -68708.82 x 10 235-245 8 2.80 -5.....880 891 2.21 x 10, !235-240 8 2.45 -68909554.61 x 10 '2.45 -6,-,900 955 240-245 8 5.31 x 10 911 955 240-250 8 2.00 5.05 x 10-6 922 955 240-250 8 2.03 6.51 x 10-6 10 2.11 -6933955240-250 9.41 x 10 235-250 8 2.30 -59449551.85 x 10 *Packers did not completely seal ,... I ~ BH-4 (continued) fi!"l;'PI Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeab-j 1i ty (feet)(feet)(psi)(min)(gpm)(em/sec) 290 301 128 6 1.6 2.04 x 10-5 300 311 132 6 1.8 2.23 x 10-5 310 321 136 6 1.2 1.45 x 10-5 320 331 140 8 0.21 -6 f!~"2.48 x 10 330 341 145 6 0.80 9.16 x 10-6 340 351 150 6 0.92 1.02 x 10-5 I'F"'" 350 361 153 6 0.14 -61.53 x 10 360 371 158 6 0.08 8.49 x 10-7 370 381 162 6 0.83 8.62 x 10-6 380 391 165 6 0.68 -66.95 x 10 390 401 170 6 0.77 -67.66 x 10 400 411 175 6 0.32 -63.10xl0 410 421 179 6 0.24 -62.28 x 10 420 431 183 7 0.18 -61.68 x 10 430 441 188 9 0.19 -61.73 x 10 440 451 192 6 O.18 -61.61 x 10 450 461 196 6 0.17 -61.49 x 10 460 471 200 6 0.21 1.81 x 10-6 470 481 204 6 0.48 -64.06 x 10 480 491 209 6 1.1 9.10xl0-6 490 501 213 6 0.81 6.58 x 10-6 500 511 217 4 0.70 -65.59 x 10 510 521 220 7 0.90 -67.10 x 10 520 531 225 6 1.0 7.73 x 10-6 530 541 230 6 0.52 3.94 x 10-6 540 551 234 6 0.83 -66.19 x 10 ~"-I 550 561 240 6 2.1 -51.53 x 10 560 571 245 6 0.80 5.72 x 10-6 6.47 x 10-6 ~- 570 581 250 6 0.92 580 591 250 6 0.55 -63.87 x 10 -6 """""590 601 250 6 0.70 4.92 x 10 600 611 250 6 0.75 5.27 x 10-6 F<':;~' i"'""SUMMARY OF WATER PRESSURE TEST RESULTS ,....Borehole Number BH-6 Location Watana-Ground Surface Elevation 1608.8 ft Static Water Level 1461.8ft. Dip of Hole 60°r-. Stickup 2.5 -5.5 ft. -I Depth Tested Gauge Duration Average Coefficient of From To Stick-up Pressure of Test Flow Rate Permeability r""(feet)(feet)(feet)(psi)(min)(gpm)(em/sec) 33.9 50 2.5 16 to 18 10 11 -4 ~4.59 x 10 48.9 65 5.5 22 to 24 10 10.8 3.27 x 10-4 63.9 80 2.5 28 to 30 10 6.4 to 8.0 -4 -41.5xl0 to 1.98xlO,-. 78.9 95 5.5 35 to 36 10 2.4 -54.81 x 10 43.9 110 2.5 41 to 44 10 2.2 -53.80 x 10 ,.."108.9 125 5.5 48 to 50 10 2.9 -5 \4.30 x 10 123.9 140 2.5 54 to 58 10 4.4 -55.84 x 10 138.9 ]55 5.5 61 to 62 10 3.7 -54.40 x 10 153.9 170 2.5 66 to 68 10 4.3 -54.72 x 10 168.9 185 5.5 76 to 78 10 4.0 -5 r 3.95 x 10 -5183.9 200 2.5 82 to 88 10 1.3 1 .23 x 10 198.9 215 5.5 92 to 98 15 1.7 -51.49 ·x 10 213.9 230 2.5 98 to 104 10 1.4 -51.19xl0 228.9 245 5.5 108 15 1.75 -51.42 x 10 r""243.9 260 2.5 114 25 1.0 7.91 x 10-6 258.9 125 25 1.2 -62755.5 8.88 x 10 273.9 290 2.5 125 45 1.2 -68.94 x 10 130 145 .51 -6288.9 305 5.5 3.90 x 10 320 2.5 140 4.9 -5303.9 25 3.38 x 10 335 5.5 140 10 6.2 -5318.9 4.25 x 10 r- I ,..... ! BH - 6 (continued) 1"'7'1_D.Elli1h-Le_s.~Gauge Duration Average Coefficient ofFromToStick-up Pressure of Test Flow Rate Permeabi 1i ty(feet)(feet)(feet)(ps i)(min_)_(gpm)(em/sec) 333.9 350 2.5 200 10 10 to 30 -5 -5.34xl0 to 1.60xl0 348.9 365 5.5 200 50 .31 to 14.7 -6 -51.65xl0 to 7.81xl0~" 363.9 380 2.5 204 10 15 to 30 -5 -7.89x10 to 1.58x10 378.9 395 5.5 202 10 15 to 30 7.91x10-5to 1.58xl0-4 -5 ~I 393.9 410 2.5 204 10 6.6 3.47x10 408.9 425 5.5 202 10 3.75 -51.98x1 0 3.02xl0-5 /'";;~-!423.9 440 2.5 202 10 5.7 438.9 455 5.5 200 15 11 to 30 5.85xl0-5to 1.59xl0-· 453.9 470 2.5 200 10 11 to 30 5.88x10-5to 1.60x10-A, -5 -468.9 485 5.5 202 15 11 to 30 5.80xl0 to 1.58xl0 11 -5 -4483.9 500 2.5 200 10 to 30 5.88.1'10 to 1.60xl0 "n -5498.9 515 5.5 202 15 7.8 4.12 x 10 513.9 530 2.5 204 15 7.5 ...95 ';,,-5 -.l.x I U -5 )r.:-~...,." 528.9 545 5.5 195 15 5.2 2.82 x 10 -5243.9 560 2.5 205 10 3.8 1 .99 x 10 558.9 575 5.5 200 15 1.45 7.71 x 10-6 -5573.9 590 2.5 195 10 5.2 2.83 x 10 _h 588.9 605 5.5 200 15 8.6 4.57 :.<10 oJ -5603.9 520 2.5 205 10 2.95 1 .55 x 10 203 10 3.35 -5618.9 635 5.5 1.76x10 2.5 198 20 .55 -6633.9 650 2.96xl0 !'N---~ BH-8 (Continued) Depth Tested Gauge Duration F10l;1 Coefficient ofFromToStick-up Pressure of Test Rate Permeabi 1ity(feet)(feet)(feet)(psi)(min)(gpm)(em/sec) 6 2.45 -5346.1 363 6.2 155 1.48x10 -5 .£"7.<:-J361.9 378 1.2 162 5 2.75 1.63x10 12.7 -5376.9 393 6.2 150 35 7.86x10 10.9 -5391.9 428 1.2 110 40 8.27x10 1.7 -5406.9 423 6.2 50 5 1.87x10 6 .4 -6421.9 438 1.2 188 2.14x10 2.4 -6436.9 453 6.2 195 5 1.24x10 451.9 468 1.2 200 8 .36 1.84x10-6 "r, 466.9 483 6.2 200 6 .54 2.74x10-6 481.9 498 1.2 200 7 .54 -62.76x10 3.05x10-6 f'l'-T<496.9 513 6.2 200 7 .60 511 .9 528 1.2 200 5 .55 2.81x10-6 526.9 543 6.2 200 5 .96 -6 %,"7'"4.87x10 541.9 558 1.2 200 6 .85 4.35xJQ-6 556.9 573 6.2 200 6 2.76 3.86x10-6 pl'''''- 571.9 588 1.2 200 7 2.05 1.05x10-5 586.9 603 6.2 200 6 .85 -64.32x10 601.9 618 1.2 200 7 2.8 1.43x10-5 616.9 633 6.2 200 6 .75 3.81x10-6 631.9 648 1.2 200 6 .82 4.20x10-6 646.9 663 6.2 225 8 1.60 7.46x10-6 661.9 708 1.2 200 6 .80 -64.09x10 676.9 723 6.2 200 7 1.1 5.59x10-6 691.9 738 1.2 200 6 1.08 5.53x10-6 fJ'''!:~'1 706.9 6.2 200 6 1.2 6.09x10-6 721.9 1.2 200 12 1.0 -65.12x10 """SUMMARY OF WATER PRESSURE TEST RESULTS Borehole Number BH-12 Location Watana Ground Surface Elevation 1975.7 ft. Static Water Level 1975.7 ft. Dip of Hole 36 0 Stickup 7.1 ft. Depth Tested Gauge Duration Coefficient of From To Pressure of Test Fl ow Rate Permeability (feet)(feet)(psi)(mi n)(gpm)(em/sec) 30.0 41.0 10 10 3.10 4.52 x 10-4,... 41.0 4.73 x 10-430.0 8-10 10 3.00 40.0 51.0 14 10 6.35 7.08 x 10-4 50.0 61.0 15 6 2.91 3.07 x 10-4 60.0 71.0 20 8 0.07 5.78 x 10-6_.70.0 81.0 22 10 0.036 2.73 x 10-6, 80.0 91.0 27 10 0.18 1.14 x 10-5 1-90.0 101.0 30 8 0.45 2.59 x 10-5 *100.0 111.0 30 3 0.82 4.72 x 10-5 *105.0 116.0 30 4 0.99 5.70 x 10-5 r-121.0 10-5 j 110.0 35 10 0.30 1.50 x, j 10-5120.0 131.0 38-40 10 0.32 1.42 x f"""1 130.0 141.0 42 10 0.53 2.24 x 10-5 140.0 151.0 44 12 0.19 7.70 x 10-6 ~150.0 161.0 48-49 12 0.60 2.22 x 10-5 160.0 171.0 51 6 0.17 6.00 x 10-6 r 170.0 181.0 54 6 0.05 1.67 x 10-6 180.0 191.0 58 6 0.02 6.29 x 10-7 190.0 201.0 60 6 0.10 3.02 x 10-6 200.0 211.0 65-66 6 0.39 1.08 x 10-5 210.0 221.0 70-71 10 1.67 4.30 x 10-5 220.0 231.0 71 6 0.30 7.72 x 10-6 *230.0 241.0 No Test r- *Packers did not completely seal-I {~'" BH -12 (continued) Depth Tested Gauge Duration Coeffi ci ent of From To Pressure of Test Flow Rate Permeability (feet)(feet)(ps i)(min)(gpm)(em/sec)r-'~O\ 235.0 246.0 73-74 6 0.21 5.27 x 10-6 240.0 251.0 77 6 0.18 4.29 x 10-6 250.0 261.0 80-82 6 2.54 5.76 x 10-5 *260.0 271.0 84-85 11 0.70 1.52 x 10-5 r~,'-I 270.0 281.0 88-92 8 2.45 5.02 x 10-5 275.0 286.0 86-90 11 2.12 4.40 x 10-5 *286.0 289.0 No Test 289.0 300.0 91-92 11 2.02 4.07 x 10-5 -5 P'~\299.0 310.0 92-98 10 1.00 1.94 x 10 309.0 320.0 98-103 12 0.90 -51.64 x 10 *310.0 321.0 98-99 310.0 321.0 98-99 10 0.89 1.67 x 10-5 *321.0 324.0 No Test ,\'1"""4 324.0 335.0 104-108 10 4.75 8.62 x 10-5 329.0 350.0 No Test p'" 349.0 360.0 110 6 0.56 9.45 x 10-6 359.0 370.0 114-116 8 1.05 1.70 x 10-5 369.0 380.0 117-119 10 0.76 1.20 x 10-5 380.0 391.0 120-122 10 0.79 1.21 x 10-5 390.0 401.0 126-128 8 1.48 2.17 x 10-5 """-;:';·-1 400.0 411.0 128-132 10 1.77 2.54 x 1O~5 410.0 421.0 132~134 10 0.66 9.25 x 10-6 1'-""-"'-" 420.0 431.0 134-136 8 0.84 1.16 x 10-5 430.0 441.0 136~140 10 0.74 1.00 x 10-5 440.0 451.0 140 10 0.89 1.19 x 10-5 450.0 461.0 144 8 0.91 1.18 x 10-5 ~?- 460.0 700.0 Hole Cavinq,Redri 11 ed and Tested From Bottom Up 700.0 711.0 222~226 10 0.75 -66.30 x 10 710.0 721.0 226-228 6 0.75 -6 F'"''6.22 x 10 720.0 731.0 232-236 8 0.81 -66.52 x 10 730.0 741.0 230-234 6 0.80 -66.49 x 10 740.0 751.0 234 8 0.77 ~66.20 x 10 750.0 761.0 238-244 8 1.59 -51.24 x 10 p;-.tc:-, *Packe~s did not completely seal. BH -12 (continued) Depth Tested Gauge Duration Coefficient of From To Pressure of Test Fl ow Rate Permeability 1"-1 (feet)(feet)(psi)(min)(gpm)(em/sec)I, 760.0 771.0 240-246 10 1.27 9.84 x 10-6 770.0 781.0 242-250 14 2.25 1.72 x 10-5 780.0 791.0 250-256 10 2.10 1.56 x 10-5 r i~ I""" I ,"""I r r v - ,,;.t>:... APPENDIX E DEVIL CANYON WATER PRESSURE TESTING DETAILS ~~l <",",,~-~)',-:J "'-]'1 -1 ",.'I 1 )......,].)-_.._]~"1 1 -')-~"-J -I SURGE TANK HOSE WATER SOURCE FLEXIBLE HOSE BY-PASS VALVE FILTERL~LUW -CONTROL VALVES FLEXIBLE HOSE FLOWMETER PANEL PRESSURE GAUGE 0-300psi AW DRILL RODS INFLATiON LINE INFLATABLE PACKERS SCHEMATIC VIEW OF WATER PRESSURE TEST ASSEMBLY • ~~ SUMMARY OF WATER PRESSURE TEST RESULTS (Borehole Number BH-1 Location Devil Canyon Ground Surface Elevation 1413.7 ft. Static Water Level 1221.7 ft. Dip of Hole 67 0 Stickup 3 to 8 ft. I""'" Depth .Te~.t~Gauge Duration Coefficient of From To Stickup Pressure of Test Flow Rate Permeability I-(feet) (feet)(feet)(ps i )(min)(gpm)(em/sec) 38.9 55 8 20 11 .72 2.34 X 10-5 53.9 70 3 30 10 4.06 1.03 X 10-4 68.9 85 8 40 10 6.18 1.18 X 10-4 "....,83.9 100 3 45 10 .78 1.33 X 10-5 98.9 115 8 55 10 5.17 7.23 X 10-5 -113.9 130 3 60 46 .90 to 5.40 1.16 X 10-5 to 6.95 X 10-5 128.9 145 8 70 21 .77 8.50 X 10-6 143.9 160 3 75 14 .83 8.57 X 10-6 158.9 175 8 85 11 1.05 9.58 X 10-6 173.9 190 3 90 10 .06 5.18 X 10-7 (1!JI/fIJlI;188.9 205 8 100 10 2.16 1.68 X 10-5 203.9 220 3 105 10 2.19 1.63 X 10-5 r-218.9 285 8 115 10 0·.84 5.89 X 10-6 233.9 250 3 120 10 2.70 1.87 X 10-5 248.9 265 8 130 10 5.37 -5,..,.3.50 X 10 263.9 280 3 135 10 .25 1.61 X 10-6 278.9 295 8 145 10 3.63 2.22 X 10-5 292.9 310 3 150 10 2.05 1.24 X 10-5 308.9 325 8 160 10 1.24 7.11 X 10-6-2.38 X 10-6,323.9 390 3 165 10 .42 \{: 8.15 X 10-6338.9 355 8 170 10 1.48 ,....,252.9 370 3 180 10 1.61 8.61 X 10-6, I 1.10 X 10-5368.9 385 8 190 10 2.15 383.9 400 3 195 10 .26 1.32 X 10-6 BH-l (Continued) For;·". Depth Tested Gauge Duration Coefficient of From To Sti ckup Pressure of Test Flow Rate Permeabi 1Hy (feet)(feet)(feet_)(ps i )(min)(gpm)(em/sec)F"""' 398.9 415 8 200 10 .40 1.97 X 10-6 413.9 430 3 200 10 1.98 9.84 X 10-6 428.9 445 8 200 10 .29 1.43 X 10-6 443.9 460 3 200 10 1.15 5.72 X 10-6 458.9 475 8 200 10 5.08 2.50 X 10-5 473.9 490 3 200 10 7.21 3.58 X 10-5 488.9 505 8 200 10 2.34 1.15 X 10-5 503.9 420 3 200 10 1.48 7.35 X 10-6 518.9 535 8 200 10 4.2 2.07 X 10-5 r-:"-", 533.9 550 3 200 10 .39 1.94 X 10-6 548.9 565 8 200 10 4.51 2.22 X 10-5 563.9 580 3 200 10 3.72 1.85 X 10-5 578.9 595 8 200 10 3.9 1.92 X 10-5 p-'\- 593.9 610 3 200 10 9.7 4.82 X 10-5 608.9 625 8 150 13 2.58 1.54 X 10-5 7.91 X 10-6 f"'·'''''·622.9 639 3 130 18 1.20 638.9 655 8 130 11 1.63 4.11 X 10-6 653.9 670 3 200 10 7.4 3.68 X 10-5 668.9 685 8 130 11 1.03 6.72 X 10-6 683.9 700 3 150 25 .45 2.71 X 10-6 698.9 715 8 150 19 .69 4.12 X 10-6 713.9 730 3 150 13 .23 1.39 X 10-6 728.9 745 8 150 14 .78 4.66 X 10-6 BH-2 (Continued) Depth Tested Gauge Duration Flow Coefficient of ""'~'C', From To Stickup Pressure of Test Rate Permeabil ity (feet)(feetl (feet)(ps i )(min)(gpm)(em/sec) 388.9 405 2 190 10 .38 2.78 x 10-6 403.9 420 7 200 10 .62 -64.27 x 10 x 10-6 ,FKG'j 418.9 435 2.200 10 .36 2.51 433.9 450 7 200 10 .61 -64.20 x 10 r~c' SUMMARY OF WATER PRESSURE TEST RESULTS Borehole Number BH-3 Location Devil Canyon Ground Surface Elevation 1398.0 ft. Static Water Level dry hole Dip of Hole 32° Stickup 7.1 ft. Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability (Feet)(Feet)(ps ;)(min)(gpm)(em/sec) 20.0 31.0 18 10 1.35 -59.5 x 10 1""',30.0 41.0 22 8 0.71 -5!4.1 x 10 ;-540.0 51.0 12 8 0.36 2.7 x 10 r-50.0 61.0 16-22 8 4.4 -42.6 x 10 60.0 71.0 22 8 0.72 -53.4 x 10 70.0 81.0 20-22 12 0.71 -5-3.3 x 10![ 80.0 91.0 25 10 0.98 -53.9 x 10 90.0 101.0 28-29 8 0.32 -51.1 x 10 100.0 111.0 30 12 0.28 -69.3 x 10 11 O.0 121.0 30 2 11.0 -43.5 x 10 ;~120.0 131.0 2.4 6.8 x 10-5358 130.0 141.0 38 8 1.1 -52.9 x 10 I"""140.0 151.0 41-46 6 11 .0 -42.6 x 10 150.0 161.0 45-46 6 3.4 -57.7 x 10 160.0 171.0 46 2 11.0 -42.4 x 10 170.0 181.0 48 6 2.45 -55.1 x 10 180.0 191.0 52 10 5.6 -4 i 1.1 x 10 -5190.0 201.0 54 12 4.6 8.6 x 10 200.0 211 .0 60 20 2.2 -53.8 x 10 210.0 221.0 60 4 11 .0 -41.9 x 10 220.0 231.0 64 10 0.80 -51.3 x 10,.... 230.0 241.0 65 20 2.3 -53.6 x 10 240.0 251.0 68-77 14 0.58 -68.4 x 10 250.0 261.1 72-74 4 11.0 1.6 x 10-4 BH-3 (Continued) Depth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability (Feet)(Feet)(ps i )(min)(gpm)(em/sec) 260.0 271.0 72-75 8 5.6 -57.8 x 10 270.0 281.1 77 6 11 .0 -41.5 x 10 280.0 291.1 79-80 6 5.3 -56.8 x 10 290.0 301.1 83 8 8.9 -41.1 x 10 300.0 311 .1 86 8 5.7 -56.8 x 10 310.0 321 .1 88-90 7 1.1 -51.3 x 10 320.0 331 .1 80-91 8 8.7 -41.0 x 10 341.1 92-94 7 11 .0 -4330.0*1.2 x 10 351 .1 96-97 6 11.0 -4340.0*1.2 x 10 350.0*361 .1 100 6 11.a 1.1 x 10-4 100-102 8 8.2 -5360.0 371 .1 8.3 x 10 8 11.0 -4370.0*381 .1 105 1.1 x 10 9 11 .0 -4380.0*390.7 108 1.1 x 10 (~ SUMMARY OF WATER PRESSURE TEST RESULTS Boreho 1e Number BH-4 Location Devil Canyon,-Ground Surface Elevation 1352.6 ft Static Water Level 1321.6 ft Dip of Hole 60 0 Stickup 1 to 6 ft 1""'1 Depth Tested Gauge Durat i on Coefficient of From To Stickup Pressure of Test Flow Rate Permeability (feet)(feet)(feet)(ps i)(mi n)(gpm)(em/sec) 13.9 30 I 10 10 .046 3.48 X 10-6 28.9 45 6 15 10 .252 1.15 X 10-6 43.9 60 1 20 10 .247 1.03 X 10-5 58.9 75 6 24 10 .039 1.38 X 10-6 78.9 90 1 34 12 3.21 9.48 X 10-5 88.9 105 UNABLE TO SEAT PACKERS,.... 10-6108.9 125 14 50 10 .26 5.29 X 118.9 135 6 55 10 3.75 7.46 X 10-5 123.9 140 1 56 10 4.24 8.58 X 10-5 138.9 155 UNABLE TO SEAT PACKERS ,....,148.9 165 6 70 10 .052 8.54 X 10-7 \ 153.9 170 1 50 10 1.042 2.31 X 10-5 r'"'163.9 180 1 80 10 .622 9.37 X 10-6 178.9 195 6 85 10 .041 5.74 X 10-7 193.9 210 1 95 10 .034 4.41 X 10-7 208.9 225 6 100 10 .02 2.44 X 10-7 223.9 240 1 105 10 .029 3.45 X 10-7 r-238.9 255 6 115 10 .048 5.18 X 10-7 253.9 270 1 125 10 .034 3.46 X 10-7 208.9 205 6 130 10 .036 3.48 X 10-7 283.9 300 1 140 10 .028 2.57 X 10-7 r-298.9 315 6 145 10 .105 9.22 X 10-7 313.9 330 1 150 10 .033 2.85 X 10-7 328.9 345 6 160 12 .423 3.40 X 10-6 !~ BH-4 (Continued) ~-""'~ f.epth Tested--Gauge Duration Coefficient of From To Stickup Pressure of Test Flow Rate Permeability (feet)(feet)(feet)(ps i )(mi n)(gpm)(em/sec) 343.9 360 1 170 10 .208 1.60 X 10-6 358.9 375 6 175 10 .113 8.36 X 10-7 r~":c' 373.9 390 1 185 10 .92 6.54 X 10-6 388.9 405 6 190 9 .09 6.17 X 10-7 403.9 420 1 200 10 .151 9.98 X 10-7 418.9 435 6 200 10 .121 7.92 X 10-7 433.9 450 1 200 10 .119 7.87 X 10-7 448.9 465 6 200 10 .099 6.48 X 10-7 458.9 475 1 200 10 .103 6.81 X 10-7 - -SUMMARY OF WATER PRESSURE TEST RESULTS Borehole Number BH-5a----------- Location Devil Canyon Ground Surface Elevation 974.5 feet Static Water Level 935.6 feet Dip of Hole 45 0 Stickup 4.0 feet f"""', f) Depth Tested Gauge .Duration Coefficient of From To Pressure of Test Flow Rate Permeability (feet)(feet)(psi)(minutes)(gpm)(em/sec) 63.0 74.0 30 6 0.89 3.5 x 10-5 73.0 84.0 30 6 0.93 3.6 x 10-5 83.0 94.0 33 6 0.71 2.6 x 10-5 93.0 104.0 36 6 1.0 3.5 x 10-5 103.0 114 40 8 2.5 8.2 x 10-5 .~114.0 115.9 f 'No Test 115.9 126.9 40 16 3.4 1.1 x 10-4 126.9 135.6 No Test 135.6 146.6 55 8 0.76 2.0 x 10-5 -143.0*154.0 55 4 9.4 2.4 x 10-4 ~. 10-7153.0 164.0 60 2 0.01 2.4 x 163.0*174.0 60 6 9.2 2.2 x 10-4-10-4I173.0 184.0 65 10 5.1 1.2 xJ 183.0 194.0 70 4 0.06 1.3 x 10-6 ,-.193.0 204.0 70 4 0.09 1.9 x 10-6 203.0 214.0 75 6 0.04 8.2 x 10-7 r'213.0 224.0 80 4 0.10 1.9 x 10-6 ,223.0 234.0 85 8 0.14 2.6 x 10-6 l, 233.0 244.0 85 8 0.16 2.9 x 10-6 243.0 254.0 90 6 0.10 1.8 x 10-6 *Packers did not completely seal BH-5a (Continued) _~~pth Tested Gauge Duration Coefficient of From To Pressure of Test Flow Rate Permeability (feet)(feet)(psi)(minutes)(gpm)(em/sec) 253.0 264.0 95 6 O.14 2.4 x 10-6 263.0 274.0 95 6 0.13 2.2 x 10-6 273.0 284.0 100 6 0.58 -69.3 x 10 283.0 294.0 105 12 1.0 -51.5 x 10 293.0 304.0 .11 0 12 1.1 -51.6 x 10 303.0 314.0 110 18 1.7 -52.5 x 10 313.0 324.0 115 8 1.4 -52.0 x 10 323.0 334.0 118-120 0.13 -681.8 x 10 -7 ~7;!333.0 344.0 124 8 0.07 9.4 x 10 343.0 124 0.58 -6354.0 8 7.8 x 10 353.0 132 0.21 -6364.0 8 2.7 x 10 363.0 374.0 132 8 0.87 1.1 x 10-5 373.0 384.0 134 0.40 -685.0 x 10 t;:~':i':. 383.0 0.22 -6394.0 139 8 2.7 x 10 393.0 144 8 0.45 -6404.0 5.3 x 10 :m--:-""--6403.0 414.0 145 8 0.33 3.8 x 10 413.0 148 -6424.0 8 0.30 3.4 x 10 -6 p."". 423.0 434.0 150 8 0.35 4.0 x 10 433.0 444.0 155 1.7 -581.9 x 10 443.0 162 2.1 -5 F"'-~:'"454.0 8 2.2 x 10 453.0 464.0 164 0.29 -673.0 x 10 463.0 2.6 -5474.0 171 8 2.6 x 10 473.0 484.0 170 5.9 -566.0 x 10 484.0 503.0 No Test 503.0 514.0 180 10 0.82 7.9 x 10-6 513.0 524.0 185 6 0.93 8.7 x 10-6 -5 f'l-7"""523.0 534.0 190 8 3.7 3.4 x 10 533.0 544.0 190 6 -53.3 3.0 x 10 543.0 195 5.4 -5 ~,554.0 6 4.8 x 10 553.0 -6564.0 200 4 0.38 3.3 x 10 563.0 574.0 200 6 0.66 -65.8 x 10 573.0 584.0 205 0.47 -684.0 x 10 581.7 -6592.7 210 6 0.43 3.6 x 10 fr"'/"e; SUMMARY OF WATER PRESSURE "'"',\TEST RESULTS Borehole Number BH-5b Location Devil Canyon r-Ground Surface Elevation 976.6 ft Static Water Level 946.2 ft ~Dip of Hole 45° Stickup 2.2 -4.0 feet ""'"t Depth Te.?J~_~Gauge Durat ion Flow Coefficient ofFromToStickupPressureofTestRate0ermeab)i 1i ty,,-(fee_t)(feet)(feet)(psi)(m-in)(gpm)em/sec! 23.0 34.0 4.4 21 7 0.51 3.1 x 10-5 33.0 44.0 4.0 25 6 1.4 -56.9 x 10 43.0 54.0 4.0 28 6 11 .0 -44.9 x 10 54.0 63.0 No Test 63.0 74.0 4.0 32 6 0.06 2.4 x 10-6 I"""68.3 79.3 2.2 30 8 0.33 1.4 x 10-5 79.3 116.0 No Test 116.0 127.0 2.2 46 6 0.68 2.2 x 10-5 I"""10-5I126.0 137.a 2.2 52 6 0.10 2.9 x, 136.0 147.0 2.2 55 8 0.47 1.3 x 10-5 !""""'"146.a 157.0 2.2 58 6 0.71 1.9 x 10-5 156.0 167.0 2.2 60 6 0.67 1.7 x 10-5 166.0 177.a 2.2 65 8 1.7 4.1 x 10-5 176.0 187.0 2.2 70 6 0.64 1.5 x 10-5 r-186.0 197.0 2.2 70-72 8 0.18 4.0 x 10-6 !"""' I r- SUMMARY OF WATER PRESSURE TEST RESULTS Borehole Number BH-7 Location Devil Canyon Ground Surface Elevation 1351.0 ft .-Static Water Level 1338.3 ft., Dip of Hole 45° Stickup As Noted Depth Tested .Gauge Duration Coefficient of From To Stickup Pressure of Test Flow Rate Permeability (Feet)(Feet)(Feet)(ps i)(mi n)(gpm)(em/sec) 30.0 47.0 6.1 20 8 5.2 -42.6 x 10 35.9 52.0 1.1 20 6 O.19 -51.0 x 10 50.9 67.0 6.1 20 6 0.38 -5 I"'""1.9 x 10 65.9 82.0 1.1 25 6 3.2 -41.4 x 10 80.9 97.0 6.1 30 14 3.6 -41.3 x 10 95.9 112.0 1.1 35 11 3.0 -41.0 x 10 11 o.9 127.0 61.40 8 1.9 -55.6 x 10 125.9 142.0 1.1 45 22 0.89 -52.5 x 10 138.9 155.0 7.0 48 20 0.04 -61.1x10 148.9 165.0 3.1 50 10 0.02 -75.0 x 10 163.9 180.0 3.1 55 10 0.03 -76.9 x 10 178.9 195.0 8.1 60 10 0.03 -7 !""'"6.1 x 10 -6188.9 205.0 8.1 60 12 0.22 4.5 x 10 205.0 233.0 No Test 233.9 253.1 3.1 80 9 0.38 6.2 x 10-6 248.1 265.0 8.1 80 10 0.26 4.1 x 10-6 263.9 280.0 3.1 85 6 0.22 3.4 x 10-6 278.9 295.0 8.1 90 7 0.11 1.6 x 10-6 ~293.9 310.0 3.1 95 10 0.07 9.7 x 10-6 I 10-6I308.9 325.0 8.1 102 10 1.1 1.4 x .....323.9 340.0 3.1 105 10 0.43 5.4 x 10-6, 10-6338.9 355.0 8.1 110 8 0.44 5.2 x 353.9 370.0 3.1 115 10 0.61 7.1 x 10-6 po,, .... BH-7 (Continued) Depth Tested Gauge Duration Coeffi ei ent of From To Stickup Pressure of Test Flow Rate Permeability (feet)(feet)(feet)(psi)(min)(gpm)(em/sec) 368.9 385.0 8.1 120 10 0.78 8.5 x 10-6 383.9 400.0 3.1 124 9 0.90 9.7 x 10-6 398.9 415.0 8.1 128 10 0.58 6.0 x 10-6 413.9 430.0 3.1 135 10 0.65 6.5 x 10-6 428.9 445.0 8.1 140 10 0.56 5.3 x 10-6 443.9 460.0 3.1 145 10 0.67 6.2 x 10-6 458.9 475.0 8.1 150 10 0.63 5.6 x 10-6 473.9 490.0 3.1 155 10 0.62 5.4 x 10-6 478.2 494.3 8.1 158 12 0.70 5.9 x 10-6 r r - APPENDIX F WATANA BORROW AREA INVESTIGATION r i EXPLANATION OF SELECTED SYMBOLS STANDARD SYMBOLS g ~tAVI ~......-ORGANIC MATERIAL COBBLES a BOULDERS ,,f~IGNEOUS ROCK SANOY SILT~~ a CLAY ~CONGLOMERATE I]METAMORPHIC ROCK ~SILT GRADING TO SANDY SILT ~E2H II ~SANDY GRAVEL,SILT SANDSTONE ICE.MASSIVE SCATTERED COBBLES.........{ROCK FRAGMENTS) ~Ed I!J 8 I NTERLAYERED SANDSANDMUDSTONEICE-SILT Q~3 a SANOY GRAVEL 0°0 GRAVEL ~II MESTONE ~ORGANIC SILT ~SILTY CLAY w/TR SAND°000 00 l""" I SAMPLER TYPE SYM BOLS ..... I r S I .....1.4"SPLIT SPOON WITH 47#HAMMER Ts •.••SHELBY TUBE S••••••1.4"SPLIT SPOON WITH 140#HAMMER Tm ••••MODIFIED SHELBY TUBE SI •••••2.5"SPLIT SPOON WITH 140#HAMMER Pb ••••PITCHER BARREL Sh •••••2.5"SPLIT SPOON WITH 340#HAMMER Cs ••••CORE BARREL WITH SINGLE TUBE S••••••2.0"SPLIT SPOON WITH 140#HAMMER Cd ••••CORE BARREL WITH DOUBLE TUBESz•••••1.4"SPLIT SPOON WITH 340#HAMMER B•••••BUll<SAMPLESp•••••2.5"SPLIT SPOON,PUSHED A •••••AUGER SAMPLE H••••••1.4"SPLIT SPOON DRIVEN WITH AIR HAMMER G •••••GRAB SAMPLE HI •••••2.5"SPLIT SPOON DRIVEN WITH AIR HAMMER NOTE:SAMPLER TYPES ARE EITHER NOTED ABOVE THE BORING LOG OR ADJACENT TO IT AT THE RESPECTIVE SAMPLE DEPTH. TYPICAL BORING LOG 30'T.D.-TO TAL DEPTH 95 26' SCHIST -GENERALIZED SOIL OR ROCK DESCRIPTION SAMPLE LOCATION SANOY SI LT ___~APP~XI~~TESTRATA CHANGE Liltle 10 NoVi,ible Ice 13"30'V.-ICE,DESCRIPTION 8 CLASSIFICATION \ 72,571 0/0,85.9 pel,28~GP (CORPS OF ENGINEERS METHOD) \'" ",,'UNIFIED OR FA4 CLASSIFICATION "TEMPER4TURE,OF DRY DENSITY WATER CONTENT BLOWS/FOOT SAMPLE NUMBER SANDY GRAVEL Elev.274.6 -ELEVATION IN FEET All SOl1)ple,S,__SA~PLER TYPE ORGANIC MATERIAL ~ Can sld_VIsible Ice 0-7 ICE+ML I ICE -SILT Estimate 65°/0 Visible Ice I '30,56.2 %STRATA CHANGE ~~I-----"~-~~.2..__..L..__7' BORING NUMBER T.H.30-15 DATE DRILLED---10_21_80 FROZEN GROUND SAMPLER TYPE.... Ss WATER TABLE-,..... 9'*--=,!~?;;fj WD. r i DRILLING SYMBOLS Note:Water levels indicated on the boring logs are the levels measured in the boring at the times indicated.In pervious unfrozen soils,the indicated elevations are considered to represent actual ground water conditions.In impervious and frozen soils,accurate determinations of ground water elevations cannot be obtained within a limited period of observation and other evidence on ground water elevations and conditions are required. ...... I ,I WD: WL: W5: While Drilling Water Level While Sampling AB: TD: After Boring Total Depth r-' I i. ...... PREPARED BY I PREPARED FOR: EXPLANATION OF SELECTED SYMBOLS r < ..... SOILS CLASSI FICATION AND CONSISTENCY CLASSIFICATION:Identification and classification af the soil is accomplished in accordance with the Unified Soil Classification System.Normally,the grain size distirbution determines classification of the soil.The soil is defined according to major and minor constituents with the minor elements serving as modifiers of the major elements.Minor soil constitutents may be added to the classification breakdown in accordance with the particle size proportions listed below;(i .e., sandy silt with some gravel,trace clay). no call -0-3%trace -3-12%some -13-30%sandy,silty,gravelly ->30% Identification and classification of soil strata which have a significant cobble and boulder content is based on the unified classification of the minus 3 inch fraction augmented by a description (i.e.,cobbles and boulders)of the plus 3 inch fraction.Where a gradation curve,which includes the plus 3 inch fraction,exists (samples from test trenches and pits)a modifier is used to describe independently the percentage of each of the two plus 3 inch components.If there is no gradation curve incorporating the plus 3-inch fraction (as in auger holes),the plus 3-inch material is described as a single component (i.e.,cobbles and boulders),and a modifier is used to indicate the relative percentage of the plus 3-inch fraction based on the field logs.The modifiers in each case are used as fol lows: Scattered -0-40%Numerous ->40% - r-, i SOl L CONSISTENCY -CRITERIA:Soil consistency as defined below and determined by normal field and laboratory methods applies only to non-frozen material.For these materials,the influence of such factors as soil structure,i.e.fissure systems,shrinkage cracks,slickensides,etc.,must be taken into consideration in making any correlation with the consistency values listed below.ln permafrost zones,the consistency and strength of frozen soils may vary significantly and unexplainably with ice content,thermal regime and soil type. Cohesion less Soils N* (blows/ft)Relative Density Cohesive Soils N* (blows/ft)qu -(tsf) Very Loose Loose Medium Dense Dense Very Dense 0-4 4 -10 10 -30 30 -50 >50 20% 20 to 40% 40 to 60% 60 to 80% >80% Very Soft Soft Medium Stiff Very Stiff Hard 0-2 2 - 4 4 -8 8 -15 15 -30 >30 o -0.25 0.25 -0.5 0.5 -1.0 1.0 -2.0 2.0 -4.0 >4.0 Standard Penetration tiN":Blows per foot of a 140-pound hammer falling 30 inches on a 2-inch OD split-spoon except where noted. Often the split-spoon samplers do not reach the total intended sample depth.Where this occurs the graphic log notes a refusal (Ref.)and give an indication of the cause of the refusal.Tight soils are indicated by a blow count value followed by a penetration length in inches.The presense of large rock fragments is indicated by a cobble and boulder callout following the refusal callout.In certain instances a blow count of 100+may be listed to indicate tight soils where total sampler penetration is possible with more than 100 blows per foot. ..- i i PREPARED BY'PREPARED FOR: - EXPLANATION OF ICE SYMBOLS Perct:ntage of visible Ice has been grouped for the purpose of designating the amount of soil ice content.These groups have arbitrarily been set out as follows: -0% 1%-10% 11%-20% 21%-35% >35% No Visible Ice Little Visible Ice Occasional Visjbi~Ice Some Visible rc", Considerable Visible lee The Ice description system IS bdsed on tha t prcsenl"J by K.A.LineD,and C.W.Kaplar (1966).In this system,which IS an ext.~nsion of the Unified Soil Classification System,the amount and physical clldracteristics of the soil Ice are accounted for.The following table IS a brief summary of the salient points of their classification system as modified to meel the needs of this study. r ICE DES CR I PT ION S GROUP ICE VISISI L1TY 8 SYMBOL N Ice not Visible CONTENT DESCR~T~~_R~O~-~YM8OL Poorly bonded N or friable f -:.-.e-I-I~-:~de e~c;ss~---iN;:; 1-'-------,Nb 1---- bonded I Excess I N I I ell 1 be IndiVidual Ice crystals or V x inc I U 51 ons---._'------~-+--~~---I V r ----- Vs- v Ice visible,<50% Ice coatlnQ~ on particles ---+~---~Random ar irregularly oriented Ice form 0 t Ions _ Strotified or distinctly ori en ted ice formotlons ICE Ice visible,>50% Individual layer >6"thick * Ice with SOil inclusions Ice Without soil Inclusions ICE + soi I ty pe ICE ..In some tose,."here the soil is ice poor 0 thin ,ce layer moy be called out by specrol notation on the 10Q.Ie 2"ite lens at 7' -EXPLANAT!ON OF !eE SYMBOLS PRePARED FOR: r r F.l BORROW SITE D -~ - - - r r AUGER HOLE LOGS Sp Sl 51 Sl Sl Sl Sl 51 =ri=-r:;,..;;::-;;-----------0' ORGANIC MATERIAL H!TRACE SILT 31 Visible Ice,0-4.5',Vr Refusal Boulders 3.5'-6' 1i;;:=,:;:;:=1__...---- --.-----4 . 5 ' No Visible Ice,4.5'-6' TRACE ORGANIC HATERIAL,4.5'-6' Rpfusal,11.1%,SM,F4 Refusal,6.7%,SM,F2 Little Visible Ice,6'-20 Refusal,6.6%,SM,F4 SILTY SAND W!TRACE TO SONE GRAVEL Gray-Brown,Subangular to Subrounded Refusal Boulder at 20',Refusal __~-.-20 'T.D. HATER TABLE NOT ENCOUNTERED AH-D2 7-15-80C:::l:M""'~-----------O'"""'"'""'...1 ORGANIC MATERIAL G GRAVELLY SAlIDW!SO~si~TrnGray~16,25.7%,SM.F2 r:l\~_at_t_er_e_d_C_Ob_b_le_s_O _.5_'r?9 I ~20,11.4%,SM,F4 11.2~SM _1"4 SILTY SAND W!TRACE TO SOME GRAVEL Gray 9.4%,SM,F4 21' Boulder at 29',Refusal ~:.;i,I.-------------29'T.D. ,....C:O"SUL;TANT$....C:. BORRmJ AREA 0 AUGER HOL~S AH-Dl AND AH-D2 SC9.1e 1"=4' 92 Refusal SANDY SILTY GRAVEL Gray Scattered Cobbles,8'-15' ORGANIC ~ffiTERIAL , ----------0.5 2 Refusal DIORITE BOULDER 070-------1.5' 0Refusal 0 12 (§)41 (2)49 ®95 Boulder at IS',Refusal ~~-------------15'T.D. Visible Ice Lenses, 23'-27',Vs No Visible Ice,20'-23'1 N Visible Ice as layers and Coatings,2'-20,Vc+Vs SANDY SILTY GRAVEL Brown Scattered Cobbles,11.5'-30.5' Boulder at 10.5' ORGANIC MATERIAL --------0.5'~SANDY SILT W/SO~ffi GRAVEL 0'33-------1.5' @)29 G)56 '~~:,;;.;~----------0' No Visible Ice, 27'-30.5',N Refusal 30 5'T D~:.3.J~~::':'';:::;::':;:''______." S S PREPARED BY'P..PARED FOR' BORRC~i ARE.A.D AUGER HOLES ~~-D3 AND ~H-D4 Scale 1"=4 1 ~----~--------------------------------------------'--~ __35.0' SOME 35.0'-40.0'Scattered Cobbles Brown 25.0'-48.3'No Visible Ice, Nbn Gray @94,13%,SM SAND WITH SOME SILT ___40.0' Q.)78~296,CL-- SANDY SILT WITH SOME TO TRACE CLAY AND TRACE GRAVEL @ 72,16%,SM-SC::- SIUfY SAND WI'l'H TO TRACE CLAY Gray ._.__. _ .__._.__27.0' 811 __________45.0' 3d ~70,9%,SM-SC SAND WITH SOME GRAVEL AND SILT,TRACE CLAY AND SCATTERED COBBLES Gray 3d 13 Ref.50 3.0"48.3'T.D Thermal Probe Installeu to 50.0' Stand Pipe Piezometer Installed to 30.0' Sh Sh __3.0' __.27.0' ____1.5' ______---.J.5 . 0 ' 0.0' GRAVELLY SAND WITH SOME SILT SAND WITH SOME GRAVEL AND SILT Brown Brown Elevation 2221.6' ORGANIC ~ffiTERIAL 22.0'-25.0'Scattered Cobbles aDd Boulders _____--25.0' Ref.,50/4.0" SAND WITH SOME SILT Brown SILTY S~~D WITH SOME GRAVEL Brown 5.0'-7.5'Scattered ~~;p:J-=Cobbles and Boulders 7.5 I 27,SM SM~D WITH SOME SILT Brown ~!!'!"!!'!:F'1l.-=oo:-:=:-9-:=:-.0 I -10.0'Boulder ....J-O.0 I 38,SMSh Sh Sh TIn Sh 'l'm Sh AH-D5 O.O!8-14-'1 'lm 1 ,-. i I -i /""" ! I ,... iJi I: PREPARED BY' BORROW AREA AUGER HOLE PREPARED FOR' D AH-D5 Scale: Elevation 2262.9'] _._._27.0' 90,8% Ref.,50/3" 89,9%,SM Re f .,51/5.0 " SILTY SAND WITH SOME 'ra 'l'RACE GRAVEL AND SCATTERED COB~LES Gray Ref.,Cobble <::0 0 I1.....Io~..b.'-__...:.-.-'• T.D. Thermal Probe Installed to 50.0' Stand Pipe Piezometer Installed to 50.0' Sh Sh Sh Sz 0.0' __2.0' 5.0' AND SILTY SAND WITH SOME TO TRACE GRAVEL AND SCATTERED COBBLES SAND WITH SOME TO 'I'RACE SILT Gray @21 5.0'-50.0'No Visible Ice, Nbn 049,12%,SM @74,9%,SM •_._ ._.__.__1'1.0' ~----o Ref. NUMEROUS COBBLES BOULDERS 3 17,10%,SM SILTY SAND \'/ITH TRACE GRAVELGray -ffi 20 ,8%,SM 7.5' S 24b",,*-1 \ORGANIC MATERIAL 8 . 0 'Sz @)l9~2%,SM---- G)21,11%,SM TIn Sh Sh Sh SI1 Sn Sh Sn AH-D6 0.0~8-22-81 --~~ TIn-:::::::::CD ORGANIC MATERIAL Scale:1"=4' PREPARED BY I BORROW AREA D AUGER HOLE AH-D6 DREPARED FOR' Thermal Probe Installed to 48.0' Stand pipe Piezometer Installed to 27.0'. '1'.D. 40.0 I 48.3' Ref.,50/3.0",~)90;Si"- 25.0'-48.3'No Visible Ice,Nbn 27.0' SAND WITH SOME SILT Gray Ref.50/3.0" 44.0'-48.0'Boulders 30.0'-31.5'Boulder SAND WITH SOME SILT AND TRACE GRAVEL Gray Sh Sh Sz O ~, .J 15~O' WITH SOME 12%,SM Elevation 2242.9' 0.0' ORGANIC MATERIAL 24,11%,SM SM~D WITH SOME SILT Al-.JD GRAVEL Brown 20.0'-25.0'Scattered Cobbles and Boulders _25.0' 8 Ref.,40/3~~SM SAND WITH SO~lli SILT ANDTRACEGRAVEL Gray __._.__.__._27.0' s ,.... I I r- i, -! ,- i PREPARED BY' RAM CON SULTANTS,INC. BORROW AREA D AUGER HOLE AH-D7 PREPARED FOR· Scale:1"=4' __.__.27.0' Cobble 25.0'30.0'Some Visible Ice,VX,Vs SAND WITH SOME GRAVEL, TRACE SILT,CLAY AND SCATTERED COBBLES Gray __35.0' Ref.,Cobble 30.0'-45.0'Occasional Visible Ice,Vx Ref.,90/3.0",9% 45.0'-50.3'No Visible Ice,Nbn Gray 84,13%,ML SANDY SILT WITH SOrffi TO TRACE CLAY AND TRACE GRAVEL Sz Sz Sz 7%0.3' 3ater Table Not Encountered.T.D. Tn2rmal Probe Installed to 50.3' 0.5' ___IS.O' Elevation 2276.1' Gray SILTY SAND Gray 6.0'-25.0'Occasional Visible Sh Ice,Vx ®60 ,SM SAND WITH SOME GRAVEL, SILT AND SCATTERED COBBLES ~.::..:......;....._._.__.__.-:;2.7.0' CLAYEY SILT WITH SOME GRAVEL AND SAND,TRACE ORGANICS ~Brown.to Black322 46 __4.5'~~-I :5 47,lS%~M---- 0.5'-6.0'Considerable Ice,Vx,Vs @Ref.,Boulder SAND WITH SOME GRAVEL AND SILT Gray 7.0'-8.0'Boulder 0 80 ----9 .5 f~:;":':+-1 @4 7 -;14%-;sM-m:- o----=-.....-:~"""'"""------------O.0' Tm Tm Sn Sh Sh Sh Sh Sh Sh Sh Sh PREPARED BY I R&M CONSULTANTS,INC. BORROW AREA D AUGER HOLE AH-D8 DREPARED FOR: Sc Ie'1"=4 Elevation 2319.1' __.....JC64.0' ____40.0' SILT WITH TRACE TO SOME SAND AND CLAY 50.0' 7G.21%.ML Ref.,100/2" Ref.,80/6.0" ------33SAND WITH SOME SILT WEATHERED BEDROCK SANDY SILT Gray ______52.0' SAND WITH SOME GRAVEL AND TRACE SILT ___58.0' ...............01-1-7 4.0' T.D. Thermal Probe Installed to 72.0' Stand Pipe piezometer Installed to 66.0' S,1 Sh Sh Sh Sh Sh 68/5.0" 14.0'-74.0'No Visible Ice,Nb Ref.,50/5.0" Re f.,50/4 . 0 " Ref.,54/6.0" ~27'~: SAND WITH SOME SILT Aim GRAVEL Brown ®Re f.,50/5 . 0 " .__.__.__.__38.0' AH-D9 ....7_-_2.,.5....,-,.:.8..,.1.........-----------0.0' ~~1 r-,...,-...ORGANIC MATERIAL72'5M----_1.5 ' ~SILTY SAND WITH TRACEGRAVELBrown ~:,;rq.-4 {~}~4,SM _.4.5' @-6,SM SILTY SAND,Brown 6.0'Z2J"73 ,~--- Sh Sh Sh Sh Sh Sh Szr, ,... I ( r r Prepared for: BORROW AREA D AUGER HOLE AH-D9 ~&M CONSUL.TANTS.INC. Scale:1"-5 50/4.0" 35 33.0'-50.0'Scattered Cobbles and Boulders ~_~._.__"_._.__27.0' CLAYEY SILT WITH SOME SAND AND GRAVEL Gray 25.0'-50.0'No Visible Ice,Nb ...L.::::L....L.50.0 I T.D. Thermal Probe Installea to 50.0' Stand Pipe piezometer Installed to 50.0' Sh Sz Elevation 2357.8' __25.0' SILTY SAND WITH SOME GRAVEL AND TRACE CLAY Gray 7.5'-25.0'No Visible Ice,Nf __"7.j' 22 CLAYEY SILT WITH SOME SAND AND GRAVEL Gray ,._.__.__.27.0 '0 Re f.,50/5.0 " @58 Sh 0.0'AH-DIO A.~;:::.8_-.=1"'T-..:;8r=-1=-0.0 I ~:g:y";::;::~ORGANIC MATERIAL -r--A-1.5' :0.::':.':<.:SILTY SAND WITH TRACE.....GRAVEL ffiBrown ® (2)15 PREPARED BY' BORRO'N"AREA D AUGi:R HOLE AH-D10 R&M CONSULTANTS,INC. DREPARED FOR: c Ie.1"=4 I Elevation 2358.0' __._27.0' 50/5.0" 20.0'-54.8'No Visible Ice,Nb Gray 70 SILTY SAND WITH SOME AND CLAY .....,;;..L...;;........-.L__-'-'-_~54 .8 I T.D. Thermal Probe Installed to 54.8' Stand Pipe Piezometer Installed to 54.8' S11 Sh Sh Sh Sh 12.0'-20.0'No Visible Ice, Nf Gray '$i!0RGANIC MATERIAL 0.5' 2 SILT WITH SOME ORGANICS TRACE SAND AND GRAVEL Dark Bro~3.0' ~~SILTY SAND WITH SOME GRAVEL Dark Browno 0)12 @29 '-:---=.~='----0.0 I S - .1"=4' F""" I : PREPARED BY' RAM CONSULTANTS,INC. BORRO'i'1 AREA D AUGER HOLE AH-Dll DREPARED FOR: Elevation 2337.9' * GRAVELLY SAND WITH SOME SILT,SCATTERED TO NUMEROUS COBBLES AND BOULDERS . _ .__.__.__._38.0' 60.0'~~l....----: Thermal Probe Installed to 28.0'T.D. *Tricone Cuttings Filling Hole, Unable to Sample Undisturbed Material -15.0' __38.0' __--25.0' 25.0'-30.0'Some Visible Ice,Vx Ref.,30/2.0" SILTY SAND WITH SOME GRAVEL,SCATTERED COBBLES AND BOULDERS Gray ..........:.:.:.:."".__.--'--' Sh Sh Sz Sh Sz AH-D12 0.0~7-30-81 0.0' Tm ~~RGANIC MATERIALTm~1 5' Tm SILTY SAND WITH SoMB ..C)RGANICS ~~<">ffi ::rk Brown __4.0 ' D·'.,'0.5'-4.5'Some Visible Ice, Sh ®100 Vx,Vs Sh (j)100 Sz Sh ®Ref.,34/4.0" SILTY SAND WITH SOME GRAVEL AND TRACE CIAY Gray 4.5'-25.0'No Visible Ice, Nbn Scale:1 "=5 I R&M CONSUI..TANTS.INC. Pr ared for: BORROW AREA D AUGER HOLE AH-D12 ,.... I *38.0'-41.0'Flowing Sands Encountered 84 SILTY SAND WITH TRACE GRAVEL 15.0'-38.0'No Visible Ice,Nbn Brown Ref.,50/5.0" Ref. 43.0'-50.0'No Visible Ice,Nbn _._.__.__.__27.0' ~~tb.::.....R_e_f....:..50.0 I T.D. *Unable to Sample Thermal Probe InscaIled to 49.0' Stand Pipe Piezometer Installed to 49.0 '. Sh Sh Sh Sh _25.0' __27.0' SAND WITH SOME GRAVEL 38.0' W.l2..:.I- ""1>h Sh Elevation 2326.2' 11.0'-15.0'Scattered Cobbles and bouluers 80 CLAYEY SILT WITH SOME SAND Gray 15.0'-18.0'Scattered Cobbles SILTY SAND WITH SOME GRAVEL Brown ;::..:.~~~.......o.0' S ,....., I I -I r I PREPARED BY' RAM CONSULTANTS,INC. BORROW AREA D AUGER HOLE AH-D13 0REPARED FOR' Scale:1 "=4 ' SILTY SAl'l':)·\H'.L'll SO:lli TO T.R2\C:C;;GRAV6L SILTY SAND WITH SOME GRAVEL,SCATTERED COBBLES AND BOUWBRS 38.0''0*'-'-'-'- .~~f---,60.0 ' -..:""-'''--':L-75 •0 ' *25.0'-75.0'Tricone Cuttings T.D . and Caving Problems,unable to Sample Undisturbed Material. Thermal Probe Installed to 31.0' Stand Pipe Piezometer Installed to 31.0'. Sh 0.0' 50/3.0" 14.0-22.0'No Visible Ice,Nb --14.0' ___---33.0' SILTY SAND WITH SOME TO TRACE GRAVEL (j)Ref. @* .__.__.__.__..,J8.0' (042 GRAVELLY SAND WITrl SOME SILT AND SCATTERED COBBLES Brown '\ORGANIC MATERIAL 0 . 5 , ffi SILTY SAND WITH SOME GRAVEL AND SCATTERED COBBLES Brown (})16 @25 @29 Sh Sh Sh Sh Sh Sh 0.0'AH-D14 A.~8-27-81-=-,....,..-.... r~<'-~----------------~"~------------'-----~--='------------\ Elevation 2272.7' Scale:1"=5' PREPARED BY' R&M CONSULTANTS,INC. PREPARED FOR: BORROW .-\REA D AUGER HOLE AH-D14 - -I I""'" ! r- I r ..... LABORATORY TEST DATA '~"~"~'I C'~"I ]"'-~l "J .'"'1 1 1 -"'1 -~l -c-]_..c)1 PROJECT NO.052504 R ¢M DATE October 17,1980 CLIENT:Acres American,Inc.eON S U L TAN T S I INC. PROJECT NAME Susitna Hydroelectric (Watana Dam Site)SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO. LAB ~, W %Unified -0 io DEPTH "I"3 11 2"11,~,I"B/4"1/2"3/8"#4 #10 #40 #2DO .02 .005 .00 Moist.LL PI Class.NO.lrz ~zg'~ AH-Dl 5 6.0'-7.5'100 99 95 94 90 84 69 42.3 19.0 6.1 2.6 11.1 NV NP 8M AH-D1 6 8.0'-8.5'100 87 87 83 80 76 69 54 28.3 14.4 6.1 3.3 6.7 S11* ~D1 7 10.0'-10.3'--100 91 gl R7 7f..f..?,<=;7 18.2 8.2 4.9 6.6 SM* AH-D2 3 1.5'-3.0'100 80 80 80 77 73 72 67 61 47 28.5 12.0 3.2 2.9 25.7 NV NP SM AH-D2 4 3.0'-4.5'100 94 92 90 89 86 79 62 35.0 21.2 4.1 2.4 11.4 13 .9 NE...._~M AH-D2 5 4.5'-6.0'100 98 96 92 87 80 59 30.7 13.8 3.9 1.6 11.2 NV NP SM AH-D2 8 15.0'-16.5'100 99 97 93 87 70 44.0 22.5 8.9 4.0 11.3 15.5 2.2 SM AH-D2 9 20.0'-21.5'100 96 94 93 91 85 78 61 38.6 21.3lIO.3 4.2 9.4 17.5 4.2 8M ~- REMARKS'*Estimated Va1u~ **NV==Non..Viscous........NP==NoILElastic NOTE:SIEVE ANALYSIS:PERCENT PASSING PROJECT NO.052504 R ¢M DATE October 17,1980 CLIENT:Acres American,Inc.CON S U L TAN T S I INC. PROJECT NAME Susitna Hydroelectric (Watana Dam Site)SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO. DESCRIPTION 1~"%Unified4"3"2"1"3/4"1/2"3/8"#4 #10 #40 #200 .02 .005 .OO~Moist.LL PI Class. DE"llM"l\T TtJ_pn_?R?100 99.5 81.3 69.6 50.E 42.1 55.9 33.2 CL-CH 1 T (Grab Sample) DEADMAN W-80-300 100 95 93 89 87 86 80 76 58 26.9 9.2 3.0 1.3 6.6 NV**NP**SM (Grab Sample) 'I I--- lEMARKSI *Estimated ValuA **NV=Non Viscous,NP=Non Plastic NOTE:SIEVE ANALYSIS =PERCENT PASSING 1]j 7>1 I r-~l ]~]"~l "'---1 '.-"1 _.~~-] ] PROJECT NO.052506 R$MClient:Acres American CONSULTANTS,INC. DATE September 1981 PROJECT NAME Susitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO.PAG E NO.1 <.?IJJ LAB ~o ...J.FI NE WET DRY MOISTURE0.0 DEPTH I 1/2"I"3/4"1/2"3/8"4 10 40 200 .02 .005 .002 L.L.P.1.CLASSNO.~z ~z SPG DENSITY DENSITY CONTENT ltl (jj D5 4 7.5'-9.0'100 87 53 22 8 8M D5 5 10.0'-11.5'100 70 69 67 67 67 52 35 15.9 SM D5 6 15.0'-16.5'SM100767676695123.2 D5 9 30.0'-31.5'100 84 60 26.4 14 NP 13 8M D5 10 35.0'-36.0'100 85 63 44.6 17 6 16 SM-SC D5 11 40.0'-41.5'100 98 96 92 87 73 55.2 23 14 12 CL D5 12 45.0'-46.0'100 88 88 88 ~48 25 3 39 14 9 8M-8C *SMD61345.0'-7.5'100 91 84 67 40.5 15 NP 10,8 * _. D6 p,7 8.0'-11.0'100 80 55 23.2 13 NP 12,11 8M D6 9 20.0'-21.5'100 80 40 11.7 17 2 12 8W-SM __I-_ **SMD61025.0'-26.5'83 83 80 77 75 71 67 51 32.5 15 NP 9 D6 11 30.0'-31.0'8 D6 12 35.0'-36.0'100 98 94 89 83 65 40.5 17 NP 9 SM D6 13 40.0'-40.5'12 --1--- I--1-----1-------r --. REMARKS:*Sample Combined for Sieve Analysis and Atterberg Limits **100%Passing 2" NP=Non-Plastic NOTE:SI EVE ANALYSIS =PERCENT PASS I N G PROJECT NO.052506 R¢M DATE September 1981 Client:Acres American CONSULTANTS,INC. PROJECT NAME Susitna Hydroelectric 2PARTYNO.PAG E NOSUMMARYOFLABORATORYTESTDATA <!J lLJ ILAB~Ci -l.FI NE WET DRY MOISTURE0.0 DEPTH I 112"I"3/4"1/2"I 3/8"4 10 40 200 .02 .005 .002 L.L.P.I.CLASSNO.Q:z :!:z SPG DENSITY DENSITY CONTENT0<[Ia:l (/) D7 2 4.0'-5.0'11.-f----- D7 5.0'-6.0'11 f------I--_.- D7 4.h 7.0'-10.0 I +.100 97 91 88 85 79 71 51 31.2 12 11 SM D7 E 15.0'-16.5'100 90 88 8f)R4 RO 7.""i2 2f)fi 10 SM D7 ...,20.0'-20.2'6 -- D7 C 25.0'-25.7'100 94 94 94 94 77 51 23.1 2.62 9 SM D7 9 35.0'-35.2'9 ---+- D7 Ie 40.0'-40.7'~~j __lill1 79 50 19BL___2.73 9 SM l D8 5 4.5'-6.0'100 82 82 57 39 17.5 14 NP 15 SM--_.. D8 8 9.5 I -11.0'100 84 67 41.8 14 NP 14 SM-ML D8 9 15.0'-16.5'100 88 73 47 17.7 SM D8 10 20.0'-21.0'13 D8 11 25.0'-25.7'100 77 77 72 72 72 55 33 11.2 18 5 In SM-SP D8 13 35.0'-36.0 '100 97 95 91 86 72 52.6 13 ML D8 15 45.0'-45.2'9 D8 16 50.0'-50.2'7 REMARKS:*SamDle Combined for Sieve An,qlvsis.~ Np=Non-Plastic NOTE:SIEVE ANALYSIS =PERCENT PASSING ~]~]~~1 ~~-, _'7.,'J "'J ~'--1 c~l '--~J ~~l C~-J r.-.---l -----1 -1 )')~-l ---1 '--1 J PROJECT NO.052506 R$MClient:Acres American CONSULTANTS,INC, DATE September 1981 PROJECT NAME Susitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO,PAGE NO.3 t!l w 1/2"13/8" LAB ~d -I,FI NE WET DRY MOISTUREIl.o DEPTH I 1/2"I"3/4"4 10 40 200 ,02 ,005 .002 L.L P.I.CLASSNO,a:z ~z SPG DENSITY DENSITY CONTENTa~Im - D9 2 1 1:;'_'<()'100 91 91 91 _2.l 1-85 71 35.4 SM --,----~e--- D9 3 3.0'-4.5'100 91 87 71 41.4 SM -- D9 4.5'.,-6.0'93+75 SM4100.41.6 --I--. D9 5 6.0'-7.5'100 97 93 91 86 79 55 20.9 SM -~1----- D9 6 7.5'-9.0'100 86 61 23.0 SM ~ D9 7 9.0'-10.5'100 86 86 75 53 21.7 SM D9 13 40.0'-41.0'100 99 98 91.7 21 NP 21 ML t-----1--. D9 14 45.0'-46.5'100 92 87 82.7 35 7 25 ML ----t--- ---~---**'*+IBORFOWD ~¥o =1= I--b-~--,T 59 I 23BUL:B S MPLE 100 98'95.1 MH ---1--- .--'--f-----------~-~f----- >---------1---- REMARKS:NP=Non-Plastic *Sieve Size NOTE:SIEVE ANALYSIS =PERCENT PASSING 1 ]-~l '~l Cl -1 ]]1 1 ~1 --1 ]] US.Standard Sieve Openings in Inche.u.S.Standard Sieve Number s Hydrometer f~]1 II~ 12 9100...-.-.I I II 1 6 3 2 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 ~O ~IO 1 1 20 I ---J30 -.c. 00 140 'il i :t: >..., ... 50 II) 011... --I 0 0u --160 -c II) ~ II) ~I I I 1 -t---t-----j 70 Q I CLASSIFICATION 8 DESCRIPTION ----11-~--.,-----------_· I I I I I I I I I I I I I I .._-- I I I I I I I --~-.. DRAWN BY: APPROVED BY: DATE: ---_.,--~._--------- PROJECT NO. f--BORROW AREA D COMPOSITE GRADATION CURVE I I I I --- '-~I ''1 ]r-~l ~~J <'~'1 ~~l '~'l --1 ,~-'1 "'1 '-~-1 1 1 ---1 1 US.Standard Sieve Opening.In Inches U.S.Standard Sieve Number.H yd,om.'., o o 20 30 ...s: 01•40 ~ >. .Q 90 80 "- 50 : "-g ou 60 -C IIu ~70 a... QOOI'OO0.0050.010.05 200 270 QI 80 10040 O.!! 20104 !!Kl50 3 2 11/2 J 3/4 1/2 3/8 100 12 9 6 500 ~'T ---"1"~II I I I I I'I'--r-..... ,"-..:~ -- "r--. '('l ~ ""."- I """-I--- I i'.. I """" )""I~ .......r--.. ~ '-----L.._~ 0'000 80 90 70 30 20 100 10 >. ..Q -~40 (j....., a... -.r::. 00 Q> ?;60 '-~50 LJ.. BOULDERS COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes ..._~ SAMPLE NO.CONTE~T"OJ':STTY LL PI CLASSIFICATION 8 DESCRIPTION A.H~Dl-5 11.1%NIT NP S11 I SILT .AND SAND \HTH TRACE GRAVEL AND TRACE CLAY (E.C-7.5')I Non Viscous,Non Plastic BORROW .AEEA D DRAWN BY:DL APPROVED BY: DATE:December 19S0 PROJECT NO.052504 US.Standard Sieve Openinvs In Inch.,u.S.Standard Sieve Numbers Hydrometer 90 o 10 20 30 80 "-50 IIOIl..g ou 60 -C II ~ 70 ~ ... J:: CJl 40 ~ >-... 0001 1000.0050,01O.Oll 200 270 01 80 10040 0.15 20104 15o!50 3 2 IIL2 I 3/4 1/2 3/8 100 12 9 6 lIoo ....--,....- I r\I I I I I I -\-~------, I "'-I----. ~ ~ "i'--- "G )~ --~ -""~ "- - I'--. )"'"~ ~ t--'---< ----< ---. °1000 90 10 30 ".. -Cl 20 80 70 100 -&:. 0> Q> ~60 ~50cu:-~40u ~ OJ (L IBOULDERS ~BBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes ,_.~._ SAMPLE NO.CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION AH-Dl-6 6.7/~SM GRAVELLY SILTY SAND WITE TPACE CLAY 8.0-3.5 i) BORRmT AREA D DRAWN BY:DL APPROVED BY: DATE:December 1980 PROJECT NO,05250 :J 3 M '1 '-~~1 ~1 ~)-1 1 1 --;~-'--j ~-J ]-~-l 1 1 1 u.s.Slondord Sieve Openings In Inches U.S.Stondord Sieve Number s Hydrometer o 10 30 20 .....c:. CJl i 40 ~ >. .Q 90 80 50 ~..... CIou 60 ....c:: Q>o... Q> 70 a.. 0001'000.0050,01O.O~QIO.~~I)ro100MO '"""...L.III',...~II &;.oJf ~~'v <.v-~v VV IV""IIIo.VV ~'v I II I""II I 1 1 II ~ r--I;l.. I "":~ ~ "~. "" I """"I ~ I r>-", I.........., )"'"I"~ -......... '"---<t.........:--.t-- ------°rooo 10 ~40 u... Q>a.. 30 100 70 ~50c u. 80 90 20 -.c 0> Q> ~60 >..a FINES Silt SizesFine SAND MediumFine GRAVEL CoarseIBOULDERSI~BBLES!,I!1 I 1 1 SAM P LE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION AH-Dl-7 6.6%SE SILTY SAND WITH Sm~E GRAVEL,TRACE CLAY (l O.0-10.3') BORROW AREA D DRAWN BY:DL APPROVED BY: DATE:December 1 SSG PROJECT NO,05250 Lf US.Standard Sieve Openings In Inches U.S.Standard Sieve Numbe"Hydrometer 90 o 10 20 30 50 ~'"....oou 60 ..c CI>o.... «I 70 ll. 80 ..c- Ol i 40 ~ :; 0001 1000.0050.010.05010.5II()50100500 12 9 6 ;3 2 11/2 I 3/4 1/2 3/8 4 10 20-40 80 100 200 2TU,-I "II I I'I II I II II 1\ . \I .,,~ ~. -......."'-... ~ ~ ).....'0 1--- )""-~ "-.... ) ) '-, """'-..,""--- ------ .- 10 0 1000 30 20 90 70 80 '".0 100 -~ 01 CI> 3 60 ~50c LL-;40 (J ~ CI> Q. BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT DENSITY LL PI CLASSIFICATION a DESCRIPTION 25.7%NV NP SH SILTY GPAVELLY SAND W/TPACE CLAY BORROW .A.REA D DRAWN BY:DL APPROVED BY: DATE:December 1S'80 PROJECT NO.052504 11J 1 1] <~1 r~_)~-«1 C]c~~<"-'-1 -1 ~--"l ,---j ~--l --1 ----~~]~~) o o 20 30 90 80 -&; '"•40 ~ >. .Q "-50 011OIl...g ou 60 -c OIlu 70 ~ ooor ioo0.0050,010.05 200 270 Hydrometer 01 80 10040 0.5 20/04 510 U.S.Standard Sie.e Numbers 50 3 2 JIL2 I 3/4 1/23/8 100500 US.Standard Sieve OpenlnQs in Inches 12 9 6I'~-T ~f{-r , I I '0......fo---.--I .. c...., l"-i"--...I ~ ~ t--... ~ "" )~ ~--.----~1---~I - I " "-~ )~I "'- ....... -l ____...J __ 0'000 90 70 80 30 20 100 10 -~40 u.... OIl (L -.c:. 0- OIl ~60 ....~50 LL >. .0 Non Plastic FINES Silt Sizes CLASSIFICATION a DESCRIPTION Fine SAND Medium SILTY SAND WITP.S01~E Cr.AVEL.TEACE CLAY ~ULOERS ~BBLES I Coorse GRAVEL I Fine -I MOI$IU~tt U9u~SAM PLE NO.CONTENT ~NSITY LL 11.4%13.9 NP I 811 BOPROW P..REA D DRAWN BY: APPROVED BY: DATE:December 1 <::'80 PROJECT NO.0525OL:- us.Standard Sieve Openlno.in Inches u.S.Standard Sieve Number.Hydrom.t.r >..c o 10 30 20 -~ CJl i 40 ~ 90 80 ... 50 ::....oou 60 ..c..u..... 70 (L 0001 1000.0050.010.0501D.!!!lKl!IO100500 "'r-----T------T ...'"111'''-...p If.L.oJl'"~'v <v.~v v ......I ..............,......'... ~II I I I II "- I'---~ -----~I ~. "'"I ""--I "(; ""'- I '"'"... '"I --_. '"-- I - "",,-- "")I ""r-------. J-....r--"-----< ~._... 10 0 1000 20 70 90 30 100 80 >. .Q ~40 u.... til (L ~50c lL .. L: 0- til :l;60 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT I DENSITY ll.n LL NV PI NP SH CLASSIFICATION a DESCRIPTION SILTY SAND WITH SaNE GRAVEL.TPACE CLAY Non Viscous.Non Plastic BORROW AREA D 4 ~].~~1 ~]»,J .,1 iI J 11 J 11 ! ""]c.-]---1 ,...-,~J .,~_.-~J ')~-1 1 .•.-.._-.'···-1 1 '1 -"1 1 u.s.Standard Siovo Openings in Inches U.S.Standard Siovo Numbers H ydromotor o o 30 20 90 -~ 01 'Ii 40 ~ >-.Q "-50 ~WI...aou 60 -c ~.. 70 ~ 80 0001 1000.0050.010.05010.55D50100500 IM-r-+-~w '"I I''''',w"'~I'L.....,V ~,...~... .- ~...vv IVV .....,...,L...... r I'I',--w.......II I I I I r--~............. ~I'... I ~: i"--, "". "'"~ I "'"- "I ".- I '"~ )"i"-...I~ "-.I!I'--t---. ------ 10 0 1000 -.J::. CO iii ~60 20 100 70 30 80 90 Q;50c lL ~40u... Qla. >. .Q ~OULDERS ~BBLES SAMPLE NO. AE-D2-8 11.3/~ GRAVEL SAND FINES Coorse Fine Medium Fine Silt Sizes LL I Pi-r--CLASSIFICATION a DESCRIPTION 15.5 I 2.2 I SH I SILTY SM~D WITH TRACE GRAVEL,TP~CE CLAY (15.O~16 . 5 i ) BORRO~J f.REA D u.s Standard Sieve Opening.'"Inche.U.S.Standard Sieve Numbe ..Hydrometer o 20 10 30 ~ CI'I i 40 ~ 1; 90 80 50 :...oou 160 -c l\Iu... l\I700.. 0001'000.0050.010.05010.551050100500 I~~b "i::1\'"I :J/~I{£:J/O ..IV [T'"tV ov IVV 'VV ,,'"r-t-~T fT"-.,~I I I I I ~. ......... -......... I "'~- I ~ f'.- "-~I "'"~ I ~----_." ) IQ"-- )"'"I~ )"""I~ t---'"I-----........ ._---- 10 0 1000 30 20 90 >. .Do 80 70 100 -.c 01 Q) ~60 ~50c u:: ~40 l) '- Q) n. BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTION SILTY SAND WITH S OHE GRAVEL.CLAY51-I2 PILL Q.4/0 SAM PLE NO.I CONTENT I DENSITY I AH-D2-9 ~~1~~1~~~,~~~11 ~~jl~~~~~~~~~~~~~~~=~~~~===~~~~~~~~~~(20.0-n.2~:I I BORHOW AREA D DRAWN BY'DL APPROVED BY' DATE:December 1980 PROJECT NO.05250' ~1 ~]!:l 1 11 1}~~~1 ~~ID·1 j ;1 ·'1 B i .£.1 'J ~'C]~I -~-~l ---_cl C~'j _cc l ~]~-]V~_C_),C~C 'J ---)~-l __V] ]-i U_S_Standard Sieve Opening.In Inch ••U_S,Stondord SlOve N"mber.Hydrometer >, .J:j o o 30 20 90 ... .J::. 0' 'ii4O~ "- 50 :: "-cou 60 ... c: CI>u 70 ~ 80 0001 100 0.0050.010,05 200 270 01 80 rOO40 0.5 '010<1 51050 ~2 11/2 I 314 1/2 ~/8 100 Il 9 6 500 -----,-~,'I -j"rr --~-';-----'Tnt!-L''II,I],Ti~1I --.----+---=1l'----~--r-------I -i -:•~t r T t--t- I-H-t-t---![--t--t----r----r--...,I I H'I I ''--'-r . -I "1I:,t .t-Ic--r--t---~-~frr_n'-'-Jf-t++++-+-+--i---tITIiIl-j-r 1.I .,"I 1 ,I '-r--ILU-.w-W~-+--+----++{-j·+-1~++-+---rttii1Tl-I"\.\-;tt"i -,:. !~-t-i I 'I ~J1U-+-t-+--l---+-_+++++-1H-~+--H-ttIt~'I'1"\.i Il\.i . 1-1-1-H-H--+--+----tt'itt"i1--r-,--!~i j--=+='"'1~W-+-+-+-+-__iK'·HI\~+t---t-_ttti~ttt_tIIIHI-tltT1-1-··l1<:!I -~!++1\ 'i ,i I Iii=1-Li 'I ~"I I I r--frl~-","""" II-H-.-'+t:~j 1 I"" ''--L t-t-c-L--l.----.c-~""_---'m-~r+4--t-,I I -+----I "--t--~I I I I +-l .I I I 1'+' I 'r ii,i''_' I I !II I __-+HI-++-+-r--t--j---~ I I , W-l-I-+-+-+-l--t---ttt+H-T-t---t-c-++++-+-+-t-t-----t.--++-.L -+I+-'H-+ 1 +1-t j -__-.t-j --t--i!i '-------lJ'-, 20 10 30 0 1000 80 90 70 100 >, ..Q ~50 c:u: ~40o "-CI> Q. .E .~60 ~ E ---GRAVEL SAND FiNES ~ BOULDERS COBBLES -.", ..Coarse fine Medium Fine Silt Sizes [CiOY~ CLASSIFICATION B DESCRIPTION SAND WITH SOME SIT.er --tl-I CLASS SM- 4 .--IrIINS"TURtI 9'~"~TV 1-LL [PI!SAM PLE NO.CONTENT ~~,-'----+-~._--;"'~--t-- ~1-D5 ~I I I I I .t I I I I I I I I -----+-I I ------.--------------. I-I I I I I 1·------------i I !I 1 !I I --_._-_.__ BORROW AREA D AUGER HOLE AH-DS DRAWN BY:P.T. APPROVED BY:\'7.0.S.E. DATE'12/81 PROJECT NO. u.s.Standard Sieve Openings In Inches u.S.Standard Sieve Nombers Hydrometer 0 10 20 30 ....c. ""III 40 3: >. .Q ~W+JmH50 j . I 60 ... l: II u.. 70 f- ~ ~ I"-k !"k, 1 !!I I ~'"'"'" I "3/4 1/2 3/8 4 --.----,-I I'I ! I I I , " ,i ,I I III"I I I I II I I II,I I I I11I I I I I I III1 I I I I'0 i "1'"I I I I I I,I II I I -r-r::=l UG 0ססoo1 ''0 .±±+-~-H---l~ """"' ()5 I '-;-~----I 0.5 01 .L i0.05 0.01 .L__-J 1000.005 0001 80 70....c. '".•60 3: >..Qmti~50c I iL:'I...c ~40.. ~ 30 20 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FiNES Silt Sizes SAM:"LE NO.PI ~LASS CLASSIFICATION a DESCRIPTION AH-DS -5 -t-;Lj GRAVELLY SAND WITH SOME SILT I , I I I I I I I - _ BORROW AREA D AUGER HOLE AH-DS DRAWN BY;P.T. APPROVED BY ;\'1.0.S.E. DATE: PROJECT NO.0 ~'I ~1 ~~j 11 ~~~"1 ~j 1],,3 9 --1 ~---1 .--~--]---I --1 --1 .-.-1 1 .---._']..,-1 ._,--1 .]-'1 ].. u.s.Standard :';i~"e OpenlnQS in Inches u.S.Standard Sieve Numbers Hydrometer o 30 20 10 90 80 E '=!'•4O~,.., ~ 50=..cou60_ c "u 70~ 0001 1000.0050,010.05QIO.!l!l()ro100!l00 ,~~--.."/a--~'I'"oJ/V ~.--v ~v ........,............."'...,_.... I I I I '\I ,II I I I I' I !\ \ --- )\:~. '--...., I ""-- ~ ""'e I"" I ..."'""","'""i'. )I I· I. 0'000 10 70 100 ..40 fio ~30 80 90 20 .. ~ i:i: .. ~60 'ij ~ ::;50 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY LL PI CLASS CLASSIFICATION 8 DESCRIPTION AH-D5 - 6 SH SAND WITH SOME GRAVEL AND SILT BORROW AREA D AUGER HOLE AH-D5 DRAWN BY'P.T. APPROVED BY:"·~. DATE:12781 PROJECT NO.O-..-5"""25....,()~6~--J1 u.s.Standard Sieve OpenlnQs In Inches U.S.Standard Sieve Number I Hydrometer ,Q o 2() 30 <:cuu 7O~ 90 ... .&; l7' 4O~ >- .Q 50 ...... VI...oo 60 u 80 12 9 6 3 2 11/2 I 3/4 1/23/8 10 20 40 80 100 200 270'II I I '"i I I I II -+-- '")I "'")~:""I ' i i I !'-", '"'""\ I"" "\ '\ ) f'\ )If I I 10 30 80 20 90 70 100 ~ l7''iii ~60 >, ..Q...... =50l.L 'i:cuu Q:i 40 Q.. 0.0101000500100!lO Kl 5 O.r:;01 0.0r:;0.005 000,100 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT y DENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION AH-D5 - 9 I 13 14 NP SH SAND WITH SOHE SILT BORROW AREA D AUGER HOLE AH-DS DRAWN BY p.T. APPROVED BY' DATE: PROJECT NO . ~J ;;~1 '1 ,.~~I 1 u. 1 ',I 7 j )..~.~~]~--~"]"'~'--J "~-·1."1 "'1 1 '-"'--')....J ~"']~.~)-) U.S.Standard Sieve Op,nlnQS in Inches U.S.Standard 5',v_Numbers Hydrometer o o 20 90 80 30 ...cgo 41 4O~ >. .Q...•50 ~ cou 60 C "u 70 ~ 0001'000.0050.010,0501O.!l!l()!lO100!lOO /2 9 6 3 2 11/2 I 3/4 1/2 3/8 i 10 20 40 80 100 200 270 I I II I I I f"-'I'I I I II "I i ""... "'"I )i I ""'i ,i1- I I......~ 1l ....... ~ ~ ............. 1 -- ,! I '-'...f--I ..I)i '~_.I .._,...1 !:i !:'I Ii ---- I ~I , 1 I i -----.J01000 10 100 80 70 90 20 &60 "~ ~50.. "c ii: C 40 "u t 30 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes I SAMPLE NO.CO~TEN'+t.DtP~5iTY :_L PI CLASS CLASSIFICATION a DESCRIPTION I AH-DS -10 12 17 6 SM-SC I SILor:..Y SAND WITH SOME TO TRACE CLAY I I I I I i I ,--~----...-------,I ----11-+--..I .--------------I f I I I I I t------.----.------..-------- BORROW AREA 0 AUGER HOLE AH-DS DRAWN BY'P.T. APPROVED BY'\'1...Q.......s....E... DATE'12/81 PROJECT NO.OS2S06 \;,5,Standard Sieve Op"nln~.In Inch ..u,S,Standard Sieve Number,H ydrameter -<: II>u... Qla.. 20 10 70 ° 30 .<: ClI Ql ~ 40 l; ... II> '"50 (; o L> 90 80 60 '"~u ~'-I II",~~11 c..oJ/U ~,v ~v ~v ........V""~\J""...."" I ~.II I I I I t---r-..~ I----.'"I I ~ "- I "G ~ I ~ I : I ) I I I I ,' :! )I I I -~I~10 30 70 80 20 90 100 -<:e 40 Qj a.. ~50 [;: -.&: CJl..~60 >-.a °'000 ~oo 100 50 Kl ~O.~QI 0.05 0.01 0.005 Qool'OO GRAVEL SAND I FINES IIBOULDERSLCOBBLESCoarseFineMediumIFineSiltSizes~Clay Sizes I I MOO'TUJrrr-m<y~SAMPLE NO.CONTENT DENSITY LL PI CLASS CLASSI F ICATION B DESCRIPTiON 1423AH-D5-11 I 12 CL SM~DY SILT WITlj SOME TO TRACE CLAY AND TRACE GR~r .._.... I I I I L---3-..-·....--·-r-'-'"!I ~.._+-'_n __._'"_._.~"•._._~__,.~.• I ,,1=-4 ----+--------....-.--......~ I I I I I 1·..,-,--.--...----------.------ I I I 1-"--,-",--I I -----.---._-.,--------------'I I ----------_..._~.__. BORROW AREA D AUGER HOLE AH-D5 LQRAWN BY;F:'T • [APPROVED BY:"'I.O.S.E. DATE:12/81 PROJECT NO.052506 J ~1 ~8 ]2 ]~~l ~,11 .):! --'1 ---'1 .--')-""""1 '---1 ····~··I ----}'~-l '~'1 1 1 .1 ) US.Standard 518.1 OpenlnQI In Inch..U.S.Standard S18.8 Number I Hydrometer o 90 10 30 20 80 ~.t::. CI' II 40 ~ >-.J:j ...50 .. III...ooo60_ l:: II U 70 f 000,100O.OO!l0.010,011QIO.!l!l1000100!l00 ,~---..",--..'r -_,_,---,-_........._..... I \II I I I II \ . I !"-.. )1""- ""~ ""r--- "- I 13 "'-~ I".. )~ . I i ) I I --0'000 10 100 iui 40a.. 80 30 90 20 70:i:.,. 'i ~60 >-...... tl ~50 BOULDERS I COBBLES ~arse GRAVEL ICoarse SAND I FINESIFine~edium I Fine Silt Sizes SAMPLE NO.DE~LL IPI~SS CLASSIFiCATION a DESCRIPTION AH-D5 -12 39 -114 SM;-SC "I SAND WITH SOME GRA ----- ---~-- APPROVED BY:1'1.0.S.E. DATE:12/81 PROJECT NO.nS2S06 BORROWAREA D AUGER HOLE AH-D5 I I I 'I 'i'--------.------I I DRAWN BY:P •T. u.s.Standard Sieve Opening_In Inch ..U.S.Standard Sieve Numbers Hydrometer .. "....oo U o 10 20 c= II u 70 ~ 50 30 ....co \II 40 ~,.. .Q 60 80 12 9 6 3 2 11/2 I 3/4 1/2 8 4 10 20 40 80100 200 270 I I II I II I "- I I I I ",,- """......... I ~ ~ I i'- I'G "'"I ""--'"~ t-~ I I )I - I 70 20 80 30 90 100 -.J:: Q!I 'iii~60 ~ ~50 i.: C "~40 l. 10 90 0.010'000 500 100 50 Kl 5 0.5 QI 0.05 0.005 QOOI'OO BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. AH-D6 -3,4,10,8 y DENSITY LL 15 PI NP CLASS SM CLASSIFICATION a DESCRIPTION SILTY SAND WITH TRACE GRAVE I I I I I I I -I BORROW ARE.A D ATJGER HOLE AH-D6 DRAWN BY: APPROVED BY: DATE: PROJECT NO . 11 11 ~1)il 'i\"]-i .~'1 ~, I J J J j j )j'JI "1 -----1 ~----l ~-··-l --_c·')'~-l ,-]~~--)-,--~-l 1 ~1 l 1 )) u.s.Standard Sieve OpenlnQ"In Inches U.S.Standard Sieve Numbe"Hydrometer o 70 10 20 50 90 30 E co Cl> ~40 ,... .Q 80 ... Cl> VI...oou 60 COJ U... Cl> ll. 0001'000.0050.010.0501O.!l!lK>!lO100!l00 12 9 6 :5 2 11/2 I 3/4 1/2 3/8 10 20 40 80 100 200 270 .-T I T II I r'\II I I I I 1"'- 1\ I \ ~ '" ""- """'"' I ~,'""I """"I ): -.------ /0 0 1000 20 90 80 100 30 -c:: Cl> ~40 GI ll. _70 ~co II ~60 >-..Q ~50 Ii: BOULDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT y DENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION AH-D6 -6,7 12,11 13 NP SM SAND WITH SO~ffi SILT PROJECT NO.052506 APPROVED BY'W.O.S.E. DATE:12/81 BORROW AREA D AUGER HOLE AH-D6 I I I I I I I .__._._._-------------------,-1D::-:R::-:A-W-N-B-Y-'---,::P~.-T:o-.------JI u.s.Standard Sieve Openings In Inches u.S.Standard Sieve Number s Hydrometer o o 20 50 30 1: Ol .~ 40 3: >-..c "-III II>... o ou60_ c: CIl<.> 70 cf 80 12 9 6 3 2 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I I II I 1\I r'\II I ,I ~, f\ , 1 \:1\ \ \ \ f\--! \ I '\ '"I """'-"'- I ""I "" 80 90 100 70 20 30 c: ~40 "'-III ll. ~ .2' CIl~60 >-..c ~50cu: 10 90 0.0101000~oo 100 ~ID IS O.~01 0.05 0.005 0001 100 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.~~;;J~TEN';.c DJ'~SYTY LL PI CLASS CLASSIFICATION a DESCRIPTION I AH-D6 - 9 _12 17 ,2 SW-SM I SAND \HTH TRACE SILT f I I I I I,-+-I I BORROW AREA D AUGER HOLF:AH-D6 DRAWN BY:P.T. APPROVED BY:\tV.O.S •E. DATE:12/81 PROJECT NO . 'J;!~"~~11 .~})J ) "~"l ':"1 "'~C'l 1 ~"1 '1 -"1 -'1 1 --] lJ.S.S!IInIjQl'd §'~v.91l"'1~1I~in In~~n lUi:§!pnQQnl qi.v.Nijllliltn t"iyllrQ"1~t.r .'~'"~"1il I ~'~il MA ...L-If rQ 4~!!P '~f~eft:!I(X)II II I I I I'r II I r<r,~H !r lr I'fl-""r III ti'l'"lu If ~I>r "I fH H f ttl I I f·dJ mrutt1=~-=t'-'-mnttt:=t--:untntt--:ntntttt--::nntt1:tt==1ao.....~-..,-==~,.-'..-.~~.-,...•.',:':--';"'~--''..".~'~~::_.-.--..-~.-:"~I I .-c..'..••..~.10 80 20 ro ~~~~~ -~0~~'.~oo ~~~~~ .:r--......A ~50 ~50-~~~~~~ c ~~8 3~~oo~ ~~c l •o co,",.1m 70 ;~,~ 2011 I I I I I I I II I I I I I I I II I I I I I I I II I I I I I I I III I I I I I II I I I I I I I 180 10 III11 I I I I III I I I I I IIII I I I I III i I I I I I II,:I I I I I II I I I I I I',190 o I I J J J I I I I I I I I I I I I I I !I I I I -------l J !I I I (I J I I I I I I I I II I J I J (J I 100 1000!!00 100 &l ()!!I D.!!QI O.O!!0.01 0.005 0001 BOLl.DERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO AH-D6 -10 Y CONTENT I DENSITY 9 LL 15 PI NP CLASS SM CLASSIFICATION a DESCRIPTION SILTY SAND WITH SOME GRAVEL BORROW AREA D AUGER HOLE AH-D6 DRAWN BY: APPROVED BY: DATE: PROJECT NO U.S.Standard Siovo Openings in Inches U.S.Standard Siovo Number I Hydrometer -'=01 III ~ >. .Q... 0.> '"... 1:7o U o 20 30 ... C 0.>u 70 ~ 10 50 40 80 60 .-----..---.---._----_.- I I I '/I ~II II I I I I I'-- f:l--.............. -------, """-!I ~ '-..r---... "".~ -.~I ~ ~ I I )I 70 20 80 100 30 90. ... .t:. 0' ~60 >. ..Q...~50 ~... ~40u...•Q. 10 90 0 1000 !l00 100 !IO K)!I O.!I 01 0.05 0.01 0.005 aool'OO BOULDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. y CONTENT I OENSITY LL PI CLASS CLASSIFICATION B DESCRIPTION AH-D6 -12 9 17 NP SM SILTY SAND WITH TRACE GRAVEL I I I I I 1 -----I I I I I I BORROW AREA D AUGER HOLE AH-D6 DRAWN BY: APPROVED BY: DATE: PROJECT NO. ~J ~1 ~~~1 §, ~J -1 CC--J )cl -)'.~J J 1 --~J ")_c._,C] U,S,Standard Sieve Opening.in Inche.U,S,Standard Sieve Numbers Kydrometor o 30 ~ -ij ~ 10 20 ~ Gl '"50 :; oo 40 l; 70 60 ~o f -Tr----.--.--~------1 - -'-+---t-+---------I ~...-1---.---i ---'-l --- --r-c f---- r-~--==1r------ c I-+r-----j---------1tif(i ---'~_---1+ifr I~}t~~~-=--1Htrt---II)!!!I·t I I~~r-I .i,---r--_. .J+1.1 r-t---__j-----__h~r-->--1--1 100 '_.',,-_~2~c __•"'illf::='4':'I"'0 '1t -'0 'Pi"-'i'"Po =---ooffillilfl=mHJ+t-~rr~l-~ffH-a~Tf-=i= ~50H++-+--+--u::: ~Ol~~~~RS 1COBBLES --Jcoorse GRAl~ine -.==r:rs~I Mediu~_~=-__=r~i~~~-c----_r ------·=i~~~~~~=-~l;y-:01 DRAWN BY·P.T. APPROVED BY;W.O.S.E. DATE.12/81 BORROW AREA D AUGER HOLE AH-D7 e~;~~'~r~~~~~~~~;~~~I~~~~~~~~~-~------ ,--------_~-----ul .---t----t---~-------·---'----"----------------IJ__--±-----___-------.---------------------- --t ~-t-=-1 -~~------=-===-~----~.~=-----~=---'~----'-- ---------------------------------------- ____---,-_-->-1 I J L __._L__--+_ "b ..:'.;,;·-::::.:.::'·'..:~::.:-;;.:,·':.::·-;:;;-~-;,:,:":;"~·.:.:·-~'.:.:'·::;-...'--l__",.o~.___1 PROJECT ~JO U:JL::JUO I u.s.51andard Sle"le Openin\j5 in !i\Ch63 U.S Standard S,ovo Numbo"~ydromete r o o 20 ... Gl '"50 ~o U 90 70 30 ~ Gl ~ 40 :; 80 ~c60Glu... Gla.. 000,1000.0050.01 rr -r"_.-~-r=-3, I--~---- : .I->-.-- I ----- --- -r~""----'r --I, II,~,--'-1~mt'--~.-lttt·_.. '4-I T --- t1+'1 -+-~I'I:mt'==:~[illi_1_____. 100 E GRAVEL SAND ±-~-'FINESBOULDERSCOBBLES..I,'. ..----.- _.Coarse Fine Medium I Fine Silt Sizes ,~.,, __SAM~~~NO I 'co;tTENT~DENSITY +--LL I__P_I_+~ASS AH-D7 -6 rIO ~SI1 CLASSiFICATION 8 DESCRIPTION._------ SAND \'lITH Smlli SILT AND GRAVEL BORROW AREA D AUGER HOLE AH-D7 --+------------ ----I----------'--'-'--1'.'1'.=1 -------'DRAWN 8J ~_.S~.""'E._.--------.'---....--'APPROV.ED BY 12/81--- =======~==~f===j::;;~!~~~I~i DATE~____OF"F '" I I.PROJFCT NO. I I1 i )1 '1 .~.~l 1 ]~i if "J .~.~._)]-,1 -,'..'.J "])'J ~..)'I ~...•]"--I ')....J U.S.St~nd~rd Sieve Openings In Inches U.S.Standard Sieve Number I Hydrometer 90 o 20 30 E CIl 10 4O~ ~ 80 ... 50 ~...oou 60-e: 41o... el 7OQ.. QOOIIOO0.0050.010.0501O.!l!lKl!l0100!l00 --._----_....,--.- I T.- I I --•of_-,.",-If-.-.- \ '".'\. I"" I"'" I\... I "'""", ) ~ 1"- f"s '"""--I"""'""- - 1-.. ) I II 10 0 1000 100 70 80 90 20 -s::. 01 ~60 >. .Q ;50 e: i:&:-~40 o ~ Q.. 30 I COBBLES GRAVEL SANDBOUe..DERS Coarse Fine Medium Fine SAMPLE NO.13o;..jTE:NT~CLASSI F ICATION B DESCRIPTION AH-D7 - 8 9 SAND IHTH SONE SILT,TRACE GRAVEL FINES Silt Sizes BORROW AREA D AUGER HOLE AH-D7 DRAWN BY P.T. APPROVED BY'rr;r.O.S.E. DATE:12/81 PROJECT NO.U:::>L:::>O U.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numb,,.Hydrometer 90 o 30 0- ~ 01 'ij 40 ~ >- .Q o 20 80 .. 50 ~.. oou 60 .-c.,.., 70 ~ QOOIIOO0.0050.010.05QI0.55()50100500 12 9 6 3 2 11/2 I 314 1/2 3/8 10 20 40 80 100 200 210 I I r '\II I 1 I r I 1\ 1\ r \ ~ r """". "- I'" ~ ""I "'"'" I "'""'"-- ) . 10 0'000 70 30 90 80 20 100 >-..0 ~50c: iL: i 40..,.. 4Da.. ~ .~;60 BOULDERS I COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes SAMPLE NO.CLASS CLASSI F ICATION 8 DESCRIPTION AH-D7 -10 SH I SAND WITH SOHE SILT BORROW AREA D AUGER HOLE AH-D7 DRAWN BY:P.T. APPROVED BY:iv.O.S.E. DATE:12181. PROJECT NO.0~~~()b ~1 ]J ~}1 "1 ,J 1 ~;1J_'1 r J -'~~1 ~"-1 ""-'1 r-').~-")--'J '~].-'--~,-1 ---J l -)) u.s.Standard SI •••Openlnos In Inches U.S,Standard SI •••Numb..s Hydrom.ter o o 70 20 90 ~..... 50 l;o U 30 ~ "~ 401; 80 i:60 • U \- II Q.. 0.001 100 0.0050.010.050.10.5!l10!50100!loo ---.,,--.--.-.,-,,---._----_.- I I II I ,II I 1 I I \ \ -\\ \ \ \ \-- "'--~ "-,,- "0.""--- ~ I "I'...---~ ")----I I-- -~-._-".~---------_.-0 1000 10 100 30 80 90 20 70... Lgo 'j; ~60 :0- .Q.... ~50 ~ II ~40l BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FI NES --------==:J ---S-j-,t-S-iz-e-s------'p0zesl SAMPLE NO.D!ry DENSITY LL 14 PI NP CLASS SM CLASSIFICATION B DESCRIPTION SAND WITH SOIm GPJWEL AND SILT I I I I I I liD/'fi I BORROW AREA 0 AUGER HOLE AH-D8 U.S.Standard Sieve Opening.In Inch..U.S.Standar4 S18ve Numbe"Hydrometer 0, o 20 "-'"., 50 l; o U 70 90 30 ;: 00 Iii ~ 4O~ -60 ~u "-'"Q. 80 0.00,1000.0050.010.050.10.5510~100~OO 12 9 6 :3 2 11/2 I 3/4 1/2 3/8 10 20 40 80 100 200 270 I I '1 1 ~fT I I I I -- "'- c-.--'._.".---- "'" _.I I "'--. ~I -- I-.... I ~ "I "~. I-~I '"-~. 'r.l I-----f-- I I I .- -~ I),..I ~ I .-.____--'-_--.J - 10 0'000 20 30 90 100 70 80 '".£> -.c: 00 II> 3:60 c '"40~ Clll Q. ~50 Li: BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES I Silt Sizes ICloy Sizes SAMPLE NO AH-DB - 8 14 LL 14 PI NP SM-11L SILTY SAND CLASSIFICATION e.DESCRIPTION BORROW AREA D AUGER HOLE AH-DB DRAWN BY P.T • APPROVED BY:11.0.S.E. DATE:12181 PROJECT NO.052506 11 ,~1 1J ~~'"1 ~",'j ;.J ) 1 ~-CCl ').",c']C).'~'-]..).-.c.')~'-'l C_)-._.-').'c 1 ..~)-)}1\ U.S.Standard 511.1 Openings In Inch..U.S.Standard 511.1 Number I Hydrometer o 70 20 10 90 30 .c 0' 'ii ~40 ,., .Q 80 ... I) 50 ~oo (,) 60 C ~ f 000,'000.0050.010.015010.1515Kli501001500 12 9 6 3 2 11/2 I 3/4 1/2 6 4 10 20 40 80 100 200 270r, l\-I 1 I '" f\ I 1"'- I", I'-.. ~ '" '""t; I "")"""")IIt> ---0 1000 10 30 70 100 80 90 20 iu i 40 Q. i: 0''i ~60 1;' ~50u: BOULDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION AH-D8 - 9 SH SAND WITH SOHE GRAVEL AND SILT PROJECT NO. APPROVED BY:;'1.0.S.E. DATE:12/81 BORROW AREA D AUGER HOLE AH-D8 I I I 1 I I I I DRAWN BY:P •T.I U.S.Standard Siove Opening!In Inches U.S.Standard Sieve Numb.ro Hydrometer o 10 20 30 ; CI ~ 40 :; 70 90 80 it '"50 ~ ou 60 ~ u ~ II Il.. 12 9 6 3 2 II 2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 r\I P I I I II \ .._.-t------- ) I \ 0-, '"I f'-- "~ '"\, ""I I "'-~ ) 'B IE~ '-..... ~10 100 70 80 30 20 90 ...c llIl it~60 p,.a ~50 iL: ~ IIe 40 l. 0.0101000!l00 100 00 Kl !l O.!l (11 0.05 0.005 (1001'00 BOu..DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.Y CONTENT I DENSITY LL PI CLASS CLASSIFICATION B DESCRIPTION AH-D8 -11 10 18 5 SP SAND ~HTH SOME GRAVEL BORROW AREA D AUGER HOLE AH-D8 DRAWN BY:P •T. APPROVED BY;07.0.S.E. DATE:12/81 PROJECT NO.eS2S0 'J l i;\.~] ,~'\;, if " J -~-)~-l ~l ~)-]-~~,~1 c 1 u.s.Standard Slev,OpenlnQs In Inches U.S.Standard Slev,Number.H ydrameter o 20 30 10 -~ 01 CII 40 ~,.., ..Q 90 50 ~..oou 60 -c:: CIIu.. CII 70 n. 80 ,~J ~W """/'-v ~If'"oJ,'"~'w L~~~......,,.........."".........,-'v .~--I I I I'f"~II I I I I I I---l>...-r----,I I ~ I .......~ """,- I "",,-, ~ ) I I I I10 30 70-~ 01 II ~60 >.. ..Q <: ~40; n. 20 100 90 80 ~50 iJ: °1000 !lOO 100 &l ()~O.~01 0.05 0.01 0.005 000,100 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO, AH-D8 -13 13 LL PI CLASS HL CLASSIFICATION a DESCRIPTION SANDY SILT WITH SOME TO TRACE CLAY AND TRACE GRAVEL DRAWN BY:P •T. BORROW AREA 0 AUGER HOLE AH-D8 APPROVED BY:T'7.O.S.E. DATE:12/81 PROJECT NO.052 U,S,Standard Sle.e Openings in Inch ..u,S,Standard Sie.e Number.Hydrometer o o 20 30 E Cl''"~ 40 '"-Cl 90 .. II) 50 ~oou 60 C II)o 70 tf 80 000,1000,0050,010.05010,55Kl!IO100500 ,----....,,--,''I ....VI v .---.-......""...'v I I \I II I I -- I -----I-------- I ~ "- '----I'G ~ ~ '"I """"I I I )I I ._-.. 10 0 1000 "".Q 30 70 90 20 100 80 V 50c ii: c ~40 "-II) Il.. E ,£,:;60 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO,CONTENT y DENSITY LL PI CLASS CLASSIFICATION a.DESCRIPTION SM SILTY SAND WITH TRACE GRAVEL BORROW AREA D AUGER HOLE AH-D9 DRAWN BY:P.T. APPROVED BY:1"1.0 DATE: PROJECT NO.O Ji ~)~]~~:':I ~'1)J I "~'"--)""1 "'~-1 "~'1 "-')..~..))~)1 ")~'..•')1 '1 '·"'1 '1 US,Standard Sieve Openings In Inch••u,S,Standard 511\1.Num~..Hydrometer >. .0 o 10 20 c ~ 70 f 30 50 ~ ~ 40 ~ 80 ...•..... 1:1o 60 u 12 9 6 3 2 11/2 I 3/4 1/2 8 4 10 20 40 80 100 200 270 I I r 1 I'-..I I iT "-~III--...~ I ~: I'-... I 'I'-c! 1"'- I '"I, '" "'"'" ~ I )I 100 70 80 20 30 90 ~ ~50 f::u:: i 40u ~ ~ .!!';60 10 90 0,0101000!)OO 100 !)Q 10 s O,!)01 0,05 0,005 0001 100 ~lJ...DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE AH-D9 - 3 LL PI CLASS SM CLASSIFICATION a DESCRIPTION SILTY SAND WITH TRACE GRAVEL I I I I I I I ----..--,.-----~ I I I I I I I ---"I BORROVI AREA D AUGER HOLE AH-D9 DRAWN BY:P.T. APPROVED BY:h'.O.S.E. DATE:12/81 PROJECT NO U.S.Standard Sieve Opening.In Inches U.S,Standard Sieve Number I Hydrometer ... J:. ell '. 40 ~ o 20 30 10 C IIo 70 t Q. 90 ~ 50 • '"...ao 60 U 80 12 9 6 3 2 11/2 I 3/4 1/2 3/6 10 20 40 60 100 200 270 -.-,r I',,--, ......."'"I I I , "---- '-.,f'..-I ~ I "-...~ I "- "- "'"I"'" ""'\ "'0 : I I ) -10 30 20 80 90 100 70... .Il:. ell.•60 3t '".Q ~50c: iL:...c: ~40 l 0'000 ~OO \00 50 o ~0,5 01 0,05 0,01 0,005 0001'00 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO, AH-D9 - 4 y CONTENT I DENSITY LL PI CLASS S11 SILTY SAND CLASSIFICATION a DESCRIPTION BORROW AREA 0 AUGER HOLE AH-D9 DRAWN BY P •T. APPROVED BY:WoO.S.E. DATE:12181 PROJECT NO,052506 ~"'.\)0 1 ~~11 ,1 )·~-·l -~_~-J -~')1 "-),r J --J .oJ ---1 --'1 ,T'-'-_>~-) us.Standard Sieve OpenlnQs in Inches U.S.Standard Sieve Number.Hydrometer o 30 10 20 90 80 50 ~... tlo l) 60 ... c Q) u 70 ~ E CI 4O~,... ..Q 0001 1000.0050.0/0.0501O.!I!I()!l0100!l00 ~.-----..,--,..,--,-.--~-_..-.--_.. I I II '~IT _r I r II ~G II- t---.bt I'-.:r--.....I ~ ~ I ~ i'-- )'"'"'" ..~ '"I .e--'")'" )I -- !L -- 10 0'000 20 70 30 100 80 90 ~40o..•~ :»50c ii: ... &:. CI ;60,., .Q ISOUL E S ~SBLES GRAVEL SAND ==r=FINES I D R Coarse Fine Medium Fine Silt Sizes ~Clay Sizes SAMPLE NO.I CONTENT AH-D9 - 5 y DENSITY LL PI CLASSIFICATION 8.DESCRIPTION I SM I SAND \\TITH SOME SILT AND GRAVEL I I I I t-I I APPROVED BY:W.0-:-5.E. DATE:12/81 PROJECT NO. BORROW AREA D AUGER HOLE AH-D9 I I L I I I I __ I DRAWN BY:fi m I U.S,Standard Sieve Openlnosln Inche.U,S.Standard Sieve Number.Hydrometer "- II III "-oo <.> o 20 10 -c: II U 70 ~ 50 90 30 1: 01 ii ~ 40 >. J:j 80 60 0001 100 0.0050.010.05010.55IJ50100500 12 9 6 3 2 11/2 I 3/4 1/2 3/8 10 20 40 80 100 200 270 I II I "'" I I I I I "",- ""I ~ ~ "'I"'.~. 1\_. '\I -,--~-\..------t--- I \ \ .I , i :\->---- I r\ ---- ) , 1 -r ,--I------I~ I i 1~-- 10 0'000 20 >. J:j 90 70 30 100 80 t 50 t::u:: ~ .~ ;60 c ~40 "- III 0.. BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT I DENSYTY LL PI CLASS CLASSIFICATION B DESCRIPTION AH-D9 - 6 SM SAND HITH SallE SILT BORROW AREA D AUGER HOLE AH-D9 DRAWN BY p.T. APPROVED BY: DATE: PROJECT NO 052506 'J n l ~~]I),j, '~-1 oC-l )r~-l '''1 .-··-~-l ....-~.J '1 '-_..~)---1 -J U.S.Standard Sllve Openings In Inches U.S.Standard Sievi Number,Hydrometer o 20 10 90 ..•on 50 a ou 30 i •~ 40 '".a 80 60 C1Ilu.. 1Il 70 Q.. 0001'000.0050.010.05010.5!5o50100500 ,~~v ~...I,..I ....,"""T ,...oJ,'"~'v ~v ~v ......,""'...._..........- I J I I '\II I , \, I '"~ I """'", f'..", I'G " """"I """I'- )I ----. 10 0 1000 100 70 80 30 90 20 i••;II 60,... ~.. :50i:i: ~•~40l. BOLLDERS I COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes SAM PLE NO.fNTENT~CLASSI F ICATION 6 DESCRIPTION SAND WITH Sm1E SILT AND GRAVELAH-D9 -7 DRAWN BY:P.T. BORROW AREA D AUGER HOLE AH-D9 APPROVED BY: DATE: PROJECT NO. .>J.E. 12/81 U.S.Standard Sieve Openings in Inche.U.S.Standard Sieve Numb...Hydrometer o \0 20 50 30 _ s:; c::n ii 40 ~ -Cl.. I> '"...cou 60 'C"u.... 70 ll. 80 12 9 6 3 2 11/2 I 3/4 1/2 3/8 10 20 40 80 100 200 270 ..i I I I I I I I-r--- -------,., -, ,: ,I I . --- I )I 90 30 70 20 80 100 ...s:; 01 'Ai 60 ~ >. -Cl ~50 c IL: ~40 u: 10 90 0'000 !l00 100 (l()[)!5 O.!l 01 0.05 0.01 0.005 0001'00 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION AH-D9 -13 I 21 21 NP HL SILT WITH TRACE SAND l\NI2_T~CE T~Sm1E SLAY BORROW AREA D AUGER HOLE AH-D9 DRAWN BY P •T. APPROVED BY:TN.O.S.E. DATE:12/81 PROJECT NO.052506 ,~-:i I '1 11 ~;0 "3 --<}'],'"-1 1 ']'-")~-]"]'1 '-) U.S.Standard Sieve Openings In Inches U.S.Standard Sleye Number'Hydrameter o 10 20 50 30 ....c Cl' 'ij 40 ~ >. .J:l 80 ... Q> III... Coo 60 -~u 70 ~ 12 9 6 3 2 11/2 I 3/4 1/2 3/8 10 20 40 80 100 200 270 -~---I I ~II I I I II ~'------ I I I I I ): 100 20 30 70 80 90 ~ l:'t'ij ~60 ... "~50 >-.J:l i: III U:D 40 Q. 10 90 0 1000 500 100 50 Kl 5 0.5 01 0.05 0.01 0.005 0001'00 SILT WITt!SOME SAND ANDTRAC FINES Silt Sizes LAY .,-,-'~'I Fine CLASSIFICATION a DESCRIPTION SAND Medium GRAVEL BOULDERS I COBBLES _I Coarse Qine SAMPLE NO.'CONTENT~j Df~RL i PI ~~S AH-D9 -14 25 35 7 ML BORROW AREA D AUGER HOLE AH-D9 DRAWN BY:P.T. APPROVED BY:T<l.O.S.E. DATE:12/81 PROJECT NO. I U.S.Slondard Siovo OpOnlnij'in Inch..U.S.Sto"dard Sio..Numb...-~~--rl ydramo'or ... ~ QI III ~,., .Q "-•III...oo U...c: IIIo "-III (L o 10 20 30 70 50 40 90 80 60 0001 1000.0050.010.05 200 270 01 60 10040 o.~ '0'J4 ~Kl~ 3 2 11/2 I 3/4 1/2 3/6 100 12 9 6 ~oo T I t---- I 'I'T T r;-.---r---'-----+ttit=-I---=rcrrfIH r=-===I",,),. I I,:hll I I i I ---r------H -LLL -! I H-++-L .I I I ~..--l I _I.~~I I .I ;IiI . ,+--to ,--·-~,··H-~--J-....=±- =tj___I:i;:': -- +-'~-'-"--'l-~.--':-lIj'~J ;"'-',---, -------LrL>-.-'-t-..~-L---iEi1jtitFt .--- ~. _qll I I Ij_ffiITrl-t---e---. -- , --l +-~II I ! I .1 iii i I I i --E ) , I _. l I I I I I -I I I I I 1 . ---j I II Ll-,-_~~1 I 100 20 90 80 70 10 0'000 ...60-g •:lit 50>. .Q..•c:: i.i:40 'C ~i 30 11. BOULDERS COBBLES GRAVEL SAND ==:=1 FINES ~ Coarse Fine Medium Fine .Silt Sizes ~CIOY?izes SAM PLE NO I CONTENT~I oE'N'sYrv I LL I PI CLASS CLASSIFICATION a DESCRIPTION IlH SILT WITH SOME TO TRACE CLAY AND TRACE SAND OR CLAYEY f I I I SILT WITH TRACE SAND I BORROW D BULK I I I 59 I 23 I I I I I I ---"---'--' I I I I I I -----I BORROW AREA D BULK SAMPLE DRAWN8Y:P.T. APPROVED BY:\"I.O.S.E. DATE:12/81 PROJECT NO.05 '\1 1 -~~1 -,col --1 ~l ----]I',]~--J ---1 -----~l -)-]-.,)-] U_S.Standard Siovo Openlnlls in Inches u.S.Standard Slev.Number.Hydram.t.r o o 30 20 90 -I:: 01 i 40 ~ >. "Q... 50 ::...oou 60 -c ~... el70a.. 80 QOOIIOOO.OO!i0.010.01lQIO.ll!l10!iO100!lOO .-~---..,-.-,..,-.,,--.-fY---._----_.- II i"- """"""""I ~: ....... I\- '", '"'\ I I I )I L_~____~.---0 1000 10 Q;50c u.. 30 90 70 100 80 20 -.c Ol -Q; ~60 ~40u... Q) a.. >. ..Q I ~GRAVEL SAND FINES BOlX...DERS COBBLES Coarse Fine Medium Fine Silt Sizes ~'_I _._ CLASSIFICATION a DESCRIPTION Hedium to High PlasticitySILTANDCLAYCL-CH PI 33.2 I I ---I LL ..:..:....+---=~55.9 SAMPLE ~CONTENT 1 nFN!'lITV W-80-282 142.1% Ie) DEAD~'!AN BORROW AREA DRAWN BY:DL APPROVED BY: DATE:December 1980 PROJECT NO.05250 U.S.Standard Sieve Openings in Inches u.S.Siandard Sieve Number s H ydromeler o 20 10 30 .. &: CIl i 40 ~ >. .Q 90 80 .... 50 =...aou 60 .. l: GI ~ OJ700.. QOOI'oo0.0050.010.05 2.00 270 QI 80 10040 0.5 20104 5o50 3 2.11/2 I 3/4 1/2 3/8 100 12 9 6 500 \0 30 20 80 0 1000 90 70 100 >. .Q Q;50c LL ~40u '- Q> 0.. -.J::. '"Q> ;;:60 FINES Silt SizesFine SAND MediumFine GRAVEL ,Coarse[SmJLDERS ~BBLES!I I I !., , SAM PLE NO.I CONTENT I DENSITY LL I PI I CLASSIFICATION 8 DESCRIPTION W-80-300 I 6.6%I I NV I NP I SM I Sandy I Till'with non plastic fines (Grab Sam~-----+-~I I GRAVELLY SILTY SAND WITH TRACE CLAY I Well graded DEADI1AN BORROW AP.EA DRAWN BY:DL APPROVED BY: DATE:December 1930 PROJECT NO.0'12504 ,-~j 'i ;~1 J ~j 1 , -Project No.052504 Dot e __--='l'-"l~-_"'2'""'Oc=-..!.18j.J.0_ R8 M Consultant Inc. LABORATORY COMPACTION CONTROL REPORT Job Name and Location Susitna (Watana Dam Site) Architect or Engineer Acres American Inc. Contractor ~~~_ A.Descri pt i on of Soi I :_W_e_l_l~G__r~a_d_e_d_'_T~i_l_l_'_-_G_RA_VE_~L_L_Y__','___S_I-.::L~T_Y'___"S~A=N'_=D'___'_W:.L./__=T:_::RA=C'_=E:..._::C::..=LA=y'___ B Unified SM AASHO Materi al Ma rk ~~_Classification Classification __ Source of Material Deadman Creek Sample N()0.W-80-300 I"""!. , Natural Water Content ~6%%Natural Dry Density PCF Speci fic Gravity _ Liquid Limit Non Viscous %Plastic Limit %Plasticity Index Non Plastic B.Test Procedure Used __-----'-'"T_-_l-=-8-=-0_"=-D_"_-~AA~SH""T=_O"'___ C Tes~Results:Maximum Dry Density 135.0 _____PCF Optimum Water Content 140 Sieve Analysis Size %Passing >- I- iii,-,2 125w 0 >-0: 0 r-, 1\ \, \ \I f---1-.~ 1\t< \'~h \,0 /\.'/" /\i\L \--(~\~. /u \fI" I \ \\ /\\ /,\-. rl ,\0 \ /\ /\\ /\ /\\~\\ \I I \i I f.1\\- \\~ q \'-- I \:\ .\I \I I ! \ I \ \ 1 II I I I \ I \ 130 135 100 95 93 89 87 86 80 t;o76LJ.. 58 ~ 26.9~ 9.20:: 3.0~ 1.3ui ill ...J 2 ,l~" 1 " r3/4" (1/2" 3/8" 1"""#4 i,if 10 , #40 _#200 J ..02mrn .005 .002-I I 5 10 15 WATER CONTENT -PERCENT OF DRY WEIGHT PrOject No._-=-0-=-5_2_5_0_4__ Dot e --=1=-:1=----=2=-0::...-_8:::.0:::...- R 8 M Consultant Inc. LABORATORY COM PACTION CONTROL REPORT Job Name and Location Susitna (Watana Dam Site) Archi lect or Engineer __A_c_r_e_s_A_rn_e_r_i_c__a_n_I_n_c_"_ Conlractor _ A.Descri pti on of Soi I:__S_I-=L:..::T:.-::.A:..::N:..::D:........:C:..::LA=.::.:Y=---_ Unified AASHO Malerial Mark A Classification __C_L_-_C:..::H~__Classificalion~,- Source of Material __D_e_a_~_rn_a_n__C_r_e_e_k__S_a_rn__=p=__l~e_N_o_._W_-_8_0_-_2_8_2 _ Natural Water Content 42.Hi 0/0 Nalural Dry Densily PCF SpecificGravily --_d-. Liquid Limit 5_5---=-.:"9=---_%PlastiC Limit %Plasticity Index __3=3"'--'-.-"'.2 _ B.Tes t Proced ure Use d __--=T::....---=l=-8::.0:::.......:M~e::::.t~h::::.o_'='d_"~A'___"_-___=_AA=S:"'"H:""T:..:O::.._ C.Test Resulls:Maximum Dry Density __l_0_2_"_5 PCF Optimum Waler Content----2.2....D% 100 Sieve Analysis %PassingSize #40 #200 .O~2mm .005 .002 100 99.56 81 "3 5:: 69.6 ~ 50.8 §5 u cr:wa.. vi (l] ...J >- f- iJj Z Wo >-cr:o 90 80 70 I I \., I W "\.~i I i ./I "\1'>:, v-I \.'i \.'f-a I y "-I \.k I ./I I K Y'(o i [/V i i "-\. I 1 ./i '\f-J Y I "-.'C!n I v I I 1 ,\.\. Y "\. i '\.:I\. I I 1 I \. I I ,I 'Q I I \. I !I I\.\. 1 I I I "- ,i I t \. "I '\ I !I , I I I 1"- I "- I I I I rn I !I I I I I :,I i II I i i ,I ,,:I I i i I I I i I 1 i I I I i I I I I , i I i !I, I I i I i I i I I I I !I 1 I I I I I : ,t:<;!'i'7'" 10 20 30 40 WATER CONTENT -PERCENT OF DRY WEIGHT .... ~ I - F.2 BORROW SITE E PROJECT NO.052506--------R ¢M CONSULTANTS.INC. DATE 6-15-81 ;~PROJECT NAME 5usitna HydroelectzLc SUMMARY OF LABORATORY TEST DATA PARTY NO.PA GE NO._ CD W '... ~d -.J •'L' (LO DEPTH~z ~z 12"7"3"2"l~"1"3/4',1/2 '3/8"#4 #10 if20 #40 #80 100 #20C CLASSrn(f) - El7 1 0.5'-1.0'100 98 94 89 79 76 ~SM-MH El7 2 3.5'-4.0'100 98 82 73 41.~8M---------- El7 3 10 . 0 '-10 . 5 I 76 75 70 64 56 51 46 42 35 27 19 13 7 6 4.'G?-GM E18 1 0.25'-0.75'100 92 89 76 69 61 55 45 34 20 12 5 4 2.0 GP E18 2 2.5'100 90 88 88 84 84 83 82 80 79 78 73 50 45 28.5M E18 3 5'.'0'-5.5'100 98 93 81 69 57 50 37 29 .., ..19 9 3 2 1.1 GP ----..~----- E18 4 10.0'-10.5'80 65 60 56 48 43 39 36 29 22 15 9 4 4 2.4 GP._---- ._~ E19 1 1.0'-1.5'100 98 76 65 3.6 8M E19 2 2.5'-3.0'100 99 95 53 44 1.2 SM E20 1 1.5'-2.0'100 99 99 97 81 76 3.4 5M-ML E20 2 3.0'-3.5'74 62 39 36 33 30 28 26 24 21 18 1:1 8 3 3 1.5 SP E20 3 7.5'-8.5'100 91 85 84 84 83 82 R2 81 79 72 65 49 45 B1.4 SM E20 4 11.0'-11.5'72 58 56 50 46 43 39 38 34 29 23 18 11 10 6.4 SP-SM E21 1 2.0'-2.5'100 97 92 84 82 70.3 SP-SC--- E21 2 6.5'-7.0'48 31 30 27 24 22 20 18 15 13 11 9 6 6 4.3 GP-GM 1---~_. I REMARKS:_NOTE:SIEVE ANALYSIS:PERCENT PASSIN C,.'t----"---c::(.•~f--~f~b:....~...~.C"k.~C....l--f C I-&L "~~l (i.\::r~~X ~Ie t 't 852506 R$M 6-15-81 DATEPROJECTNO. CONSULTANTS,INC. PROJECT NAME Susitna Hydroelectric PARTY NO.PA GE NOSUMMARYOFLABORATORYTESTDATA (')w ~d O:d DEPTHg§z ~z +12',7"3"2"1~"1"3/4''1/2"3/8'#4 #10 #20 #40 #80 ~100 200 CLASSm(J) E9 3 2.5'95 81 77 71 67 63 60 55 50 45 41 28 25 6.6 GM ---- EI0A 1 3.5'-4.0'82 78 71 63 58 51 46 37 31 28 21 8 6 2.5 GP-- EI0l\2 6.5'-7.5'100 99 89 43 35 6.5 SM EI0B 1 2.0'-2.5'100 91 86 77 66 54 48 36 28 18 11 4 3 2.1 GP---f---",, --,--------- Ell 1 1.5'100 99 94 65 58 P-LJ S,1------ Ell 2 5.0'83 73 70 66 60 56 51 47 39 33 38 22 13 11 7.J3 GP-GMf----- ------ E12 1 2.0'-2.5'79 77 74 69 62 56 50 46 37 29 21 14.2 9 8 5.,9 GP-GM E12 2 2.5'-3.5'00 94 91 90 88 86 80 59 53 38.4 SM E12 3 3.5'-4.5'79 79 75 74 73 72 71 70 66 58 40 35 23.8 SM E14 1 1.0'-2.0'100 97 85 61 20 14 5.SP-SM --- E14 2 6.0'-7.0'73 58 56 52 48 45 41 38 31 25 18 11 5 4 2.0 SP ~ E15 1 3.0'-3.5'79 77 65 50 45 37 32 26 23 17 13 9 5 2 2 • c GW--,--,----~----- ---f-------- E16 1 3.0'-i3 •.§'74 72 61 61 59 53 50 45 41 34 24 13 7 3 2 1.~SP REMARKS:_NOTE:SIEVE ANALYSIS:PERCENT PASSIN 052506 R¢M DATE 6-15-81PROJECTNO. CONSULTANTS,INC. Susitna Hydroelectric PARTY NO.PAGE NO_PROJECT NAME SUMMARY OF LABORATORY TEST DATA (9 w ~d 0::0 DEPTH ~100 1+200~z ~z +12'I 7"3"2"F-"1"3/4''1/2"3/8'#4 #10 #20 #40 #80 CLASS-, £I)Cf) ~-=~. EI 1 2.5'-3.0'96 92 82 72 61 56 47 38 33 ?7 lR 1 c;R GP-GM ~-._-- El 2 7.0'_7.5·'77 53 51 48 43 39 34 32 26 21 17 10 4 ~-~GP -..0:.""--- --~ E2 1 2.5'-3.0'84 79 79 77 73 68 62 58 51 46 38 22 5 4 ").4 SP E2 2 5.5'-6.0'64 55 54 52 45 40 35 31.23 17 12 7 ?1 .8 GW _.-- '......, E3 1 2.5'-3.0'78 54 54 49 41 37 32 28 22 16 ell 7 <?<(;T,1----- E3 2 10.5'-11.0'75 57 56 55 49 43 37 33 26 19 11 6 <--2....rL-6-Gp·-GW -----~--- -- E4 1 3.0'-3.5'58 39 38 35 30 27 24 22 18 15 10 5 2 2 .0 GP---~--- E4 2 10.5'-11.0'61 42 40 39 32 29 25 22 18 14 9 5 2 2 .2 GP ~~e---- E5 1 1.0'-2.0'79 45 42 39 34 30 25 22 17 13 9 5 2 2 .0 G\J']-GP ------ E6 1 7.5'-8.0'100 99 90 87 83 81 75 69 59 46 25 22 b3.3 SM ----- EB 1 2.5'-3.0'74 73 72 69 59 51 41 35 24 16 10 6 2 2 1 (GW E8 2 6.5'-7.0'100 99 95 89 83 77 64 46 24 10 2 2 • c -_.$P ------I---.-~-------~- E9 1 2.5'100 99 96 95 90.:ML--~---I----'---~- E9 2 4.5'01 89 87 86 85 83 81 78 76 74 70 45 38 19.c SI'lI REMARKS:_NOTE:SIEVE ANALYSIS =PERCENT PASSIN t~C.'(-~~-::;-c.~-,I~;'L __k-=-=-l,~=~ " I'~~ PROJECT NO.052504 R ¢M DATE October 17,1980 CLIENT:Acres American,Inc.CON S U L TAN T S I INC. PROJECT NAME Susitna Hydroelectric (Watana Dam Site)SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO. ~, UJ %UnifiedLABito-0 DEPTH 4"3"2"1 1 "1"13/4"1/2"3/8"#4 #10 #40 #,200 .02 .005 .000"Moist.LL PI Class.NO,O::z ~z ~g In AH-El 3 1.0'-1.5'11 nn 99 48.0 19.6 C:M AH-El 4 2.0'-3.5'100 C)R SC)'))7 1 ML* AH-E3 6 4.5'-6.0'100 89 89 83 80 7h 7)h)')))R 6.2 4 4 SP-SM AH-E3 7 6.5'-8.0'**100 90 76 62 57 40 31 16 3 7 0.7 r::TA7 AH E4 6 5.0'-6.5'1 nn 99 98 92 66 )))17 .6 C:M , AH-E7 3 2.0'-3.0'100 85 73 56 49 1c)11 1 )2.1 2.3 r::1:0 AH E9 2 1.5'-3.0'11 nn 99 28.6 1')7 C:M AH-E9 6 6.5'-8.0'100 95 87 79 ""7 44 11 17 .0 4 4 r;M REMARKS'**1-2"Rock Present in Samole *Estimated Value NOTE:SIEVE ANALYSIS =PERCENT PASSING .~--I L~..-,-~...-')--l<_~-l ~)~~ U.S.Standard Sievi OpenlnQs in Inch..U.S.Standard Sllvl Numlaa H ydrametlr 30 o >. ..Q 20 10 -.c '"i q()~ 90 80 50 :.....oou 60 -c: II> U... lU 70 c.. 000,'000.0050.010.0501 80 100 200 27040 0.5 20104 5I)50 3 2 11/2 I 3/4 1/23/8 100 12 9'6 500 .---.-J,I~RI'I""I ~r t--.I I II r--...-------- i-. ""1\r\~I\'\""~r--.~~~ I t---.. ~!\.~"'~~"'!~~ )1"'-'"1\'\\'r-...1\\'~~ ----fr';~'~'0 :::::1\\1\\~'"~-~ ::---"''\>.'-..['...~~~-r----....'<;;;;;f........\....."\'\\\\\~~I k.."'-.'-.. \,,'~,,~~~~~"'-~~'f:S ~IN 1\\\\ ~~~~"::~\~r\~",\'""~\\\,~,,\I'\t\'"~I'\~~\\~'\N ~"\\\\1\ ~-...~~"~~~~1'--"-........~"-\"~\\\,1\ "~~~~~"'~r--...---~---............I'\.\""~"\1\ '""'\~~""~~~"'::::--r--.....~1-..--........1\\,,\\\. ) ""-~~""-"-~I'(~"'"\\'\\~I ......,~~I-....'\. -..:::~"':~~~~\'"~.. J ,~ ~........~'>;;;~;;::~~"'1\'I--.~~\,r-......... "........~~:::::-""-::::::~~~~,~ \"'"""\)......I"~~~---...~~~""!!>;;.;::::::~~~---=~fIf~~~~--.,,~ II 1 ~ 0 1000 90 100 30 70 !O 20 80 >. ..Q ~50 u:: -~ '"Ql ~60 -~q() u... lUc.. BOlA..DERS I COBBLES GRAVEL Coorse I Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY LL I PI CLASSIFICATION a DESCRIPTION BORROW AREA E COMPOSITE GRADATION CURVE DRAWN BY: APPROVED BY: DATE: PROJECT NO. ~ II r J ,~ :1 r r ,I r 1 r r I I"""" 1 AUGER HOLE LOGS O' 1 r, •:J 46 Refusal SANDY GFAVEL W/TR~CE SILT Numerous Cobbles Refusal Boulder at 10',Refusa 10 'T.D. 20SILTY SM~D GRADING TO TO SAND W/SmlE SILT ff\Brown '<..I 15__________4.5' Q)ORGANIC MATERIAL ---------Q) AH-E2 7-18-80 51 Sl Sl 51 Sl Sp 25'T.0. 28 Refusal Refusal Refusal Refusal Boulder,7.5'-10' SANDY GRAVEL W/SO~E SILTBrown ~cattered Cobbles,4'-25' 100+ Refusal Boulder,20.5'-22' ORGANIC MATERIAL-.5' SILT \VSO,.,~1E SAND--.!~6~~L....I.4__1.0 ' SILTY SAND 41,27.3%,ML,F4 Tan 4' ~-W~al------- A 51 AH-El 7c-:,,:1~-"T8?0....-0' Sp 9'~vi.D':-=- l 'l.! FT I I :1 I 1 J !'j I PREPARED BY'PREPARED FOR' BORROV'AREJl.E AUGER HOLES AH-El AND AH-E2 Scale 1"=4 AH-E4 7-17-80 AH-E3 7-3-80f'"7""...-.--=-------------0 'Sp ORGANIC rffiTERIAL G~VE~W7ffiffisANiJ AND TRJ'..CE SILT "-------1' 4 5 R-.SILTY SAND @~100+-----1.5' @ 60 ,4.4 96 ,SP/SN , F20 100+,0.7%,GW,NFS Scattered Cobbles, 1.5'-20 I Refusal SANDY GRAVEL W/TRACE TO Sm1E SILT Brown,Subangular to Subrounded 100+ 94 20'T.D. Sp Sl O· ,..,·.,,....,olc.l-4/ORGAN:::C MATERIAL .--.----------0.5'o SILT 1'l/Sm1E SAND ~BrO\ill , 3''-24-------1.5 SMlD I-<l!Sm1E Sr:r~TGDt6·Oranqe-Brown .........,,-=---------------J.'~<~~~5J 22 SANDY SILT . ~=~---4.5' 26,17.6%,SM F2 Scattered Cobbles,4.5'-20' Refusal 100+ SANDY GRAVEL W/TRACE SILT Brown,Subanqular to Subrounded Refusal 20'T.D. ,~~·'i PREPARED FOR'PREPARED IIY' RA"CONSULTANTS,INC. EORR C\·I AR EJl E AUGER rlOLES At!-E3 JlND AH-E~ I'I I 51 Sl Sl Sl S1 Sl Sl A J S1 A S1 r 4 ORGANIC ~ffiTERIAL 2 -8 siLT WITAACES"ANi?1 3 38 AND ORGANIC ~ffiTERIAL ~Red-Tan 2' 4 Refusar---- 5 100+ 100+ GRAVEL W/TRACE TO SOME SILT,SOME SAND Brown,Subrounded to ~~~~~~~lar Refusal Scattered Cobbles and Boulders,2'-10' Refusal ~~"""-----------iO'T.D. WATER TABLE NOT ENCOCNTERED Sl 8 ' \'1.0. Sl Sl Sl Sl t::::"::m~';;;""-----------O' ORGk~IC ~ffiTERIAL---------.5' 3 ~~D lv/TRACE SILT -----------2.5 ""''''''.....'4''_Re fusal SANDY GRA\'EL W/TRACE SILTBrown Scattered Cobbles,2.5-6' Refusal 32 INTERLAYERED SANDY SILT AND SILTY SAt'\jDBrown ~:+9 __2~9' Refusal SANDY GRAVEL IV/SOME SILT Brown,Subangu1ar to Subrounded Scattered Cobbles,9'-26.5' Refusal 81 80 ~.......,,-------------26.5 'T.D. r I ,Rill CONSULTANTS,INC.~ BORRmJ P.REJl.E AUGER HOLES AH-E5 AND AH-EE Scale 1"=4 1 100+ SANDY GRAVEL ~]/TRACE SILT Yellow-Brown Refusal Scattered Cobbles,3'-6' Boulder at 6',Refusa1 6 'T.D. WATER TABLE NOT ENCOUNTERED 37 SAND WI SOME SILT (;RADING '~O SAND _W/TRAC~RAV~3 ' AH-E8 ...7_-.,.2...1_-_8_0 0 • _~~RGANIC ~1ATERIl\L_--0.5 ' .,::"-:: Sl Sl Sp gr.:2 ?i.f.'~.:.; S1 'i>O':: Sp Refusal Boulder at 5.5',Refusal 2.3%,Gl'-l NFS SANDY GlillVEL W/TRACE SILT Yellow-Brown Refusal Scattered to Numerous Cobbles,0-5.5' RefusalJ:.::..:::..uc.5.5'T .D. WATER TABLE NOT ENCOUNTERED AH-E7 ·c:/-~2;0,.-_B:.0~0' Sl Sl Sp PREPARED BY'PREPARED fOA' BORROVI Jl.REA E AUGER HOLES AH-E7 AND AH-E8 Scale 1"=4 F2 No Recovery SAND W/SOME SILT AND TRACE ORGANIC MATERIAL Yellow-Brown 100 Scattered Cobbles, 2.5'-8' 56 SANDY GRAVEL W/SOME SILT 4.4%.,GM,Fl Boulder at 8',Refusal ----------2.5' AH-E9 7-20-80~~------------oI .~~~ ~,;."u.------------8'T.D. A 51 Sp Sl Sl Sl ..... WATER TABLE NOT ENCOUNTERED ..... ,l/M9l. '-I, i~ PREPARED BY I BORROy!AREJI.E AUGER llOLE JlJ!-E9 Seal l"=?' PREPARED FOR' ..... -! r I""'"Ii r ..... TEST PIT/TEST TRENCH LOGS 1 TP-El __-4:.-/-1-.:9/:..-8-1--.,....---0.0' Nbn SANDY GRAVEL WITH NUMEROUS COBBLES AND SCATTERLD BOULDERS GP 0.0'-3.0'No Visible Ice, SANDY GRAVEL WITH ~HACE SILT ORGANIC MATERIAL Black B s B s 10.0'" 1"'1"' I I ITI :I t.r::1 . ~ II f I PREPARED FOR'I-;.:P:RE::P:A;R~E~D;;;B;Y~';:;;--;:::.::;-~~~~;~I·-~-_R-~-:-_-E-~-------·-"-;""'".~~l~- R OM CONSULTANTS.INC. ..Scale:1 "=2 ' 1 Nbn GW SANDY GRAVEL WITH NUMEROUS COBBLES AND SCATTERED BOULDERS 3.0'-12.0'Little Visible Ice,Vx Grayish Brown 0.0'-3.0'No Visible Ice, 'fhin Organic Layer at Surface R'~'-L_..lQ...~~L--~12 .0'T .D. TP-E2 Elevation 1436.6' :.F~Y~""-'-7VC""""-------------------0.0';~~,··~·.··,,-'O·..t'.·D:1 GRAVELLY SAl\JD ~HTH SCATTERED'.0 O ..)._o·....'o~0<1 COBBLES~V~<~~I '::~.,<".~Gray>sh nro~ :';.p./.'.}(j.....'O:.:O fJ:\r O SPu-'d>O~((\V_'__,-3.0'00·'.",09 00 9" ,.,.".o .0 '"b Bs Bs Groundwater Not Encountered. PREPAMlJ BY'PREPARED FOR' BORROW AREA E TEST PIT TP-E2 R:&Y:CONSULTANTS,r,NC. Scale:1"= ...,. , I I ----------------------------------_.~--~ IT II I.~.'. i,;1 ' 'T'·.·I:, r IJ B s B s PREPARED BY I RIM CONSULTANTS, TP-E3 4/17/81 Elevation:1464.2' __------~-------------------0.0 I ORGANIC MATERIAL 0.0'-13.0'Little Visible Ice,Vx GW SANDY GRAVEL WITH NUMEROUS COBBLES AND SCATTERED BOULDERS Grayish Brown Groundwater Not Encountered. BORROW AREA E TEST PIT TP-E3 Scale:1 "=2' -PREPARED FOR: Bs Bs PREPARED BY I RAM CONSULTANTS,INC. 'I'P-E4 Elevation:1454.9'.4,---::",1~8:--:-,8":.=1,--__--=-,.~~O.0 ' ,....,,~-..J~ .-J'""'-.J ....,__-" 0.5'-13.0'No Visible Ice,Nbn SANDY GRAVEL WITH NUMEROUS COBBLES AND SCATTERED BOULDERS Brownish Gray GP -.c--"'---=-~--=---"-..::......!"r---------L 3 •0 ' T .D. Groundwater ~ot Encountered. PREPARED FOR: BORROW AREA :2: TEST PIT TP-E4 Scale :1"=; ,~" ORGANIC MATERIAL Elevation:1470.1' 0.0' SANDY GRAVEL WITH NUMEROUS COBBLES AND SCATTERED BOULDERS Brownish Gral CD GW-GP TP-ES 4-16-81 ~~~~~-=-r:L ---,-O _0'T.D. Groundwater Not Encountered. Bs PREPARED BY:PREPARED FOR: BORROW AREA E TEST PIT TP-E::i Scale;1"=2' Bs 9.0'Y PREPARED BY' TP-E6 Elevation:1443.4' .4.---_I_~_--_8_1__~0.0 ' 0.0'-2.5'Little Visible Ice,VX SAND WITH SO[l8 GRAVEL AND SCATTERED COBBLES Brown SAND WITH SOME GRAVEL AND SILT AND SCATTERED COBBLES AND BOULDERS L--_--:.:...;.........:....,;(-'-'-'-"'-~.0 IT.D. "l I PREPARED FOR: R&M CONSULTANTS,INC. BORROh'AREA E TEST PIT TP-E6 Scale:I "=e, ~'---"---<--'---J...."----------------__4.0'T.D. T T 4.0'Y TP-E7 4/15/81 Elevation:1450.7' ----~---------O.0' ICE ,------------------2.0 t 2.0'-4.0'Considerable Visible Ice,Vx+Vs+Vr ORGANIC SILT Black PREPARED BY' R&M CON SULTANTS,INC. BORROW AREA E TEST PIT TP-E7 Scale:1"=2 ' PREPARED FOR: --,~......."..."""~~-..--..,.....~'"'---_....._-----------_._---------------------1 TP-ES 4/20/81 Elevation:1450.2' ---------.,-----------------o.0 I----.---..-~--ORGANIC MATERIAL 0.0'-7.0'No Visible Ice,Nbn SANDY GRAVEL WITH SCA'J'TERED COBBLES AND BOULDERS GRAVELLY SAND \'HTH SCATTERED COBBLES AND BOULDERS ___6.0' Brownis:.Gray Brown ---------~-- CD 27°,GWB s B s PREPARED BY:PREPARED FOR: BORROW AREA E TEST PIT TP-F,S Scale:l"=2' '1 0.5' 5 c'I..) 11.5 '1'.D. Elevation:1476.7' \'7T'T'T['>0ME GRAVEL AND SlUr COBBLES Gray SILT WITH TRACE TO SOME CLAY AND TRACE SAND SANOY GRAVEL WITH SOME SILT, AND SCATTERED COBBLES AND,BOULDERS TP-E9 4-21-81 ~~~~.......'-------0.0' ~~~~~ORGANIC MATERIAL;;z~-r---0-.-0-,---3-.-5-,-N-O-V-i-S-i-b-l-e-I-c-e-~-N-b "',,///', ,//', /,,/'///' '"'t~;:-:;~":""'"::'-<:;:-'7't-------------3 . 5 ' Bs Bs Bs fr "I 1 Groundwater Not Encountered. rr 1,1 Scale:1 "=2 I BORROW AREA E 'l'EST PIT TP-i:9 R&M CONSULTANTS,INC. PREP.....RED BY..:.'~•.-.;P..;R_E_P=A:::R=E::D::::=F::O=R:1' • rr 1 r Elevation:1500.7' __________o.o' _____________4.5' SANDY GRAVEL \'iTITH SCATTERED COBBLES Brown 7.0'-8.5'Occasional Visible Ice,Vx+Vs 9.5 r 8.0' SAl\lD AND GRAVEL WITH 'l'RACE TO SOMB SILT,SCATT2RED COBBLES ffi~D BOULDERS SAND WITH SO~lli SILT Brown 8.5'-13.5'No Visible Ice Brown SAND Brown TP-EIOA 4-22-81 ~~T777~t__-O-R~G~Al=--'~-I-C-MA~'l~'E=-R~I~A-=L-----0. 5 ' VOLCANIC ASH ____,------1.0' 0.0'-7.0'No Visible Ice,Nbn Bs Bs "-"-----:.-'--'-~._,;:..:..L 13 .0 r T .D. Groundwater Not Encountered. PREPARED BY'PREPARED FOR' BORROW AREA E TEST PIT TP-EIOA Scale:1"0=2' ,'r il !"'I""II IT'II iT Bs 9.5~ -=- SANDY GRAVEL WITH SCATTERED COBBLES AND BOU~DERS Med.to Dark Bro~l PREPARED BY I RIM CONSULTANTS,INC. BORROW AREA E TEST prr TP-EIOB Scale:1"=2 PREPARED FOR' r ---~'--'-----------------------------------, Brown 2.5'-12.0'No Visible Ice l2.0'T.D.roT'l 2 ~I•:J Elevation:1512.7' SILTY SAND Brown SAIWY GRAVi;L WITH TRACE SILT, SCATTERED COBBLES AND BOULDERS TP-Ell .41"'-:;:;:2:;:;:::;4~-~8;;;;:1~""'-:;;:;-'::=:J__~0 • 0 I ~T ~:~:'-~~;~n~~t ~~:~~s :~~:a~:e,VX ~(CDSM,~&0 Bs 12.2:Z=- PREPARED BY' BORROW AREA E TEST PIT TP-Ell Scale:1"=2 1 PREPARED FOR' ''''"''''1i?:~,' Bs Bs Bs SAND WITH SOME SILT,TRACE GRAVEL AND SCATTERED COBBLES AND BOULDERS Brown ~----"-,,-,:.;..J....---ll.0 'T.D. Groundwater Not Encountered. BY' R&M CONSULTANTS,INC. BORROW AREA E TEST PIT 'l'P-E12 Scale:1"=2' PREPARED FOR' -.----------,-----,.-----,,---------------..------.----------""'l TP-E14 4-26-81 Elevation:1503.0' PREPARED BY' RIM CONSULTANTS,INC. Bs Bs .-::::;::--;::::-::=-:?~;::-r----------------0 _0 I 2.0"Organic Mat at Surface 0.0'-3.0'No Visible Ice,Nb CD SP-SM SAND WITH TRACE SILT Brown Brown PREPARED FOR· BORROW A&A E Scale-1"=2' ~~""'_~~,_'f ""·_ 'rP-E15 T T PREPARED BY' R&M CONSULTANTS,INC. 0.0'-11.5'No Visible Ice,Nf Bs GRAVEL WITH SOME SAND, SCATTERED COBBLES AND BOULDERS Brown ____-'-.;.;..;.---llo:l--~__.=!ll.5'T.D. Groundwater Not Encountered. PREPARED FOR: BORROW AREA E TEST PIT TP-EI5 Sc Ie:1"=2 PREPARED BY I R&M CONSULTANTS,INC. Bs 1.0"Clayey silt Beneath organic Mat 0.0'-5.5'Little to No Visible Ice,Vx and Nbn GRAVELLY SAND WITH SCATTERED COBBLES AND BOULDERS Brown PREPARED FOR: BORROW AREA E TEST PIT TP-E16 Scale:1"_2' 1----.-"-----------'""'1 T rr(I ' :1 Bs Bs 11.0' TP-E17 Elevation:1441.7' .:).....'-,..-O..,..1."..-_8.,..1_r=--=."..-0.0 ' 2.0"Organic Mat at Surface 0.0'-3.0'Little Visible Ice,Vx SM--l1H SANDY SILT WITH SOME ORGANICS, TRACE CLAY Gray __.::....,<.~::zL...;..;..;.~'-+-:f-------------3.°' 3.0'-8.0'No Visible Ice,Nbn SM SILTY SAND Browi1 8.0' SANDY GRAVEL WITH TRACE SILT AND SCATTERED COBBLES AND BOULDERS Brown 3 GP-GM 1.0'T.D. ,f!"" II PREPARED BY' R-&M CONSULTANTS,INC. BORROW AREA E TEST PIT TP-EI7 Scale: ;pREPARED FOR: ""-2,li[ "'._----------------'--......_----'.,---~,'<",."~--~-----------------.~ Bs TP-E18 5-02-81 Elevation:1455.1' Brown SANDY GRAVEL WITH SCATTERED COBBLES AND BOULDERS Bs Bs Bs 0.7'-6.0'No Visible Ice,Nbn PREPARED BY: R&M CONSULTANTS,INC. Groundwater Not Encountered. BORROW AREA E TEST PIT TP-E18 Scale: PREPARED FOR: r I ''riI r r 1"-R&M CON SULTANTS.INC. Bs Bs ---l I i TP-E19 Elevation:1464.7' _5=-..::..O=2~-8~1---=-----=-----=---r-0 • 0 I 2.0"Organic Mat at Surface 0.0'-2.5'No Visible Ice,Nbn SOME CLAY 2.5'~.:;L~~~h---------- SAND WITH SOME SILT,SCATTERED COBBLES AND BOULDERS Brown t::=:.:.:....::..::.L.:;;;.;.:,l.---L2 .0 'T.D . Groundwater Not Encountered. PREPARED FOR' BORROW AREA E 'l'EST PIT TP-E19 Scale:T ":;'2 r··~----~··n_.__.~,,-~..',n_="',._-~.~.~,"-_.--- I ----~-- 12.0'T.;). Elevation:1435.0' SILTY SAND WITH ~RACE CLAY AND GRAVEL AND SCATTERED COBBLES Brown Brow., GR~VELLY SAND WITH TRACE CLAY AKD SCATTERED COBBLES AND BOULDERS SANDY SILT WITH SOME ORGAl\lICS,TRACE CLAY Brown 0.0'-2.0'No Visible Ice,NbnCDSM-ML 2.0' r:-"~~~~:,<-;-,*--~10.0' TP-E20 _5"--""",0:73--;-""8/1~",,,,,,-=,,--,0 •0 r 1.5"organic Mat at Surface Bs Bs Bs Bs 12.0'Y PREPARED BY I R&M CONSULTANTS.INC. PREPARED FOR· BORROW AR2A B TEST PIT TP-E20 Scale:1"==2 _...__.....------~-------.-_c ,_~__"_~.,"~_.."_._.--I t ,.... I Bs Bs l2.~ Elevation!1425.4' 0.0'2.5"Organic t1at at Surface 0.0'-4.5'No Visible Ice,Nb SANDY SIL'l'WITH TRACE CLAY Brown 4.5' SANDY GRAVEL WITH TRACE SILT, NUMEROUS COBBLES AND SCATTERED BOULDERS Brown BY' R&M CONSULTANTS,~C. BORROW AREA 1; TEST PIT TP~E2l PREPARED FOR: Scale:1"=2' - ~, I LABORATORY TEST DATA ~-~.J --"---=-)"".~~.""'}-'."')~~ I ~~-'..=J -;; us.Standard Sleye Openings in Inches u.S.Standard Sley.Numbers Hydrom.t.r o 30 10 20 -~ 0- 40 ~ >. .<:II 90 80 ... 50 ::...oou 60 -c:•u..... 70 a.. 12 9 -6 3 2 11/2 I 3/4 1/2 3/8 4 20 40 80 100 200 270 1 II I T r I' \ -\ )'\ \ I '\ \ I \- \. ) ) ) )I ~ 30 10 20 70 80 .C-o Q) ~60 90 100 ~40 u.... Q>a.. ....~50 LL >..a 0 1000 500 100 50 Kl !!O.!!QI 0.05 0.01 0.005 Q001 100 FINES Silt SizesFine SAND MediumFine GRAVEL CoarseIBOl1...DERS [~BBLES,,"",_,I SAM PLE NO.1 CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION AH-El-3 19.6%SH SILTY SA.ND (1.0-1.5 1) BORPDW A_REA E DRAWN BY;DL APPROVED BY: DATE:Decem1er 1S30 PROJECT NO.05 us.Standard Siove Opening.In Inches u.S.Standard Sieve Number.H ydrome'er o 20 30 10 50 -.c: CIt i 40 3t >.,g 90 80 "- lID OIl "-oou 60 -C lID ~ el70Q.. 000,1000.0050.010.05010.5!l()50100500 12 9 6 :5 2 11/2 I 3/4 1/2 3/B 4 :>20 40 BO 100 200 270,.I I ~I I I \ I \ \ ) \ I \ \ I 1\ I -c-f----f---- ) - ) )I .- 10 0 1000 -.c Ol lD ~60 20 90 70 30 loa 80 >, .0 Q;50c LL ~40 (J.... QJa.. BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM P LE NO.I CONTENT I DENSITY LL PI tiL I SANDY SILT CLASSIFICATION a DESCRIPTION BOPROH AREA E DRAWN BY:DL APPROVED BY: DATE:December PROJECT NO. ;i ~"'l ~;.'t ?,,"~'j'j..,I "1 ~)J I ....~.] .'}~.),'j "1 'I"i ~~--=:'''1 ..::.='}.~ U.S.Standard Sieve Openings in Inches U.S.Standard Sieve Number s H ydrome'er o 10 30 20 90 .- &: CJl i 40 ~ II 80 50 : L-ao U 60 .-c "u... "70 a.. 0001 100 0.0050.010.0!!01O.!!o()50100500 -~.--r-"H·6 ~2 11/2 I 3/4 1/2.3/8 4 10 20 40 80 100 200 270 II I I I II I I I I' ._~_. ,\ I;f-F"-(,.- )~: - I I'- '"~, "'" . "'" .- ~,---.~ "'"i ~I I 'ui'... )~i ~ ~ ..-- 10 0 1000 ~40u ~ 20 70 90 30 100 80 -.c 0- Cl> ~60 <Va.. Qj 50c l.L >..a [BOULDERS I COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION AH--E3-6 4.4~{'SP-SH GRAVELLY SAND (4.5-6.0')Poorly Graded BOPJWW AEEA E DRAWN BY:DL APPROVED BY: DATE:December 1980 PROJECT NO.r ')2 <;04 u.s.Standard Slo.o OponlnQs in Inches U.S.Standard Sieve Numbers Hydrometer ... G til...go U o 20 10 30 50 ... C II ~ II 70 c.. 90 -~ 0- i 40 3t >-"Q 60 80 0001'00O.omi0.010.0501O.!l!lK)~100!5oo '",..,:l "\I 4:::I :If''t/~:JleJ ..'v ",v ..v au IVU t.vu "£,(U r 1\,I'I I II \. \ \ I b I \ \ I \ I :\ I ------ 1\ I '"4 ~ I ~. ~ )i"-~ I-------.. ~ g -- 10 0 '000 20 30 90 70 80 -.<:: ""l!l ~60 100 ~50c lL ""..Cl -~40 u... w 0.. BOLLOERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Sill Sizes SAMPLE NO.'coNTEN'':~1 DENsiTY ~ AH-E3-7 0.7% (6.5-3.0 1 ) PI GW SANDY GRAVEL Hell Graded CLASSIFICATION 8 DESCRIPTION BORPOI"AREA E DRAWN BY: APPROVED BY: DATE:December PROJECT NO. 1 ~)'1 1 ]"1 ~~1 1 '7 ~/" ,....,.,-~ .~ ))•..~.)~'.-J .'~~l ~"-1 .')~'-l }.--J ']~..., "')J u.s.Standard Sieve OpenlnQs in Inches U.S.Standord Sieve Numbers Hydrometer o 20 10 30 .. ~ 01 40 ~ >. .,Q... 50 :oou 60 1: "u..... 70 a. 80 ,~~v ~...•I'".-,...,__<w,<w .---.----_.- I I II I p......I I I ,I ~ ""I '"~ ~ \ I \ I \ \.- \I 1\ 'el I) 80 70 30 90 100 20 >-..0 ~40u..., Il.. Q;50c i:L -.&:. CJI (b ;;:60 10 90 0'000 500 100 50 o II 0.5 QI 0.05 0.01 0.005 Qoo,lOO BOGt.DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION S}~I SILTY SP-..ND WITH TPACE GRAVEL (5.0-6.5'~)-II---jl----Ir---tl----t'--i,----------------------------------JI BORROW AREA E DRAWN BY: APPROVED BY: DATE:December 1980 PROJECT NO.05250 US Standard Sieve OpenlnQs In Inches U.S.Standard Si,.,Numbers Hydrameter o 20 30 10 90 50 ~011...aou 60 -C G U 70 ~ 80 -~ 00 i 40 ~ >-.0 0001'000.0050.010.05010.11II1050100500 12 9 6 ;5 2 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 '.-I \,I I I I I \ I \I I -\ \ I I~ \ I \ \ \I "-, !'-.... ~ ~ "- )If i'., "B I ~--........r-...... f0~, 0'000 10 30 70 20 80 100 90 ~50c l.L ~40u..... Ql 0... >..a s: 00 Ql:c:60 FINES Silt SizesFine SAND MediumFine GRAVEL CoarseIBOlX...DERS ~BBLES,,"I I ,I SAMPLE NO.CONTENT I DENSITY LL PI CLASSIFICATION B DESCRIPTION AH-E7-3 ~2.0-3.O·V ) 2.3%GP SANDY GRAVEL WITH TP~CE SILT BORROW AREA E DRAWN BY:DL APPROVED BY: DATE:December 1980 PROJECT NO.052504 1 1 ~:J ~)1 J~. '~).~)'1 c"")-'-.-').<.,,...._)'r),")c -1 u.S,Slandard Sieve Openlno.in Inche.U,S.Slandard Sieve Number.H ydromeler o 10 20 30 -I::. CIt i 40 ~ >.,g 90 ... 50 "'"...oou 60 -c "u 70 ~ 80 0001'00O.OO!l0.010,01l01O.1lIIo50100!lOO 12 9 6 3 2 11/2 I 3/4 1/23/8 4 ~20 40 80 100 200 270----,II I ,-1 I 1 I 1\ \ )1\ \-\ 1\ \ \ I \ \ \ ) ... 1\- I )1 - 10 0 1000 20 30 70 80 90 100 Qla... >..a -.c 0- Ql ?;60 -~40 u ~ ~50c u. FINES Silt SizesFine SAND MediumFine GRAVEL CoarseIBOUlDERS~BBLES I I I I I I I , SAM PLE NO.I CONTENT I DENSITY LL PI SAND CLASSIFICATION 8 DESCRIPTION BOP-POW AP.EA E DRAWN BY: APPROVED BY: DATE:December 1980 PROJECT NO, U.S.Standard Sieve Openings in Inches U.S.Standard Sieve Numbers Hydrometer 10 o 20 30 50 90 ... ~ 01 40 ~ >-.Q 80 ~ tl III...gou 60 ...c: to ~..70 a.. 0001'000.0050.010.0501O.llII1050100500 ---.----r ~&.-",..-,~"..-,---iT-.-'W'.....__---_..... II ""I I I I I' ""I"q \ I f--~ - 1\, \ I \, "- I ""! ""~ I ....... ~I'---..I ~ )~I ---~ 10 0 1000 20 -.c. 0- Q) ?;60 90 70 80 30 100 ~50c: l.L >. .Q -~40 u '- Q.>a. BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CO;/TENT~I DENsiTY I LL I PI I CLASSIFICATION 8 DESCRIPTION ~~~~~;~O')l4.4%1==1 I I GH I SANDY GRAVEL WITH S01m SILT I BORROW AREA E DRAWN BY:DL APPROVED BY: DATE:December 1980 PROJECT NO.nc;?C;nL<. '\1,\ .1 ').')"""1 d~,~],'],...h ..)~'l '~-)--;~,-~-1 u.s.Standard Sieve Openings In Inc~,,~U.S.Standard SI.v.Number.H~dro"'.t.r o 20 10 30 90 -s::: 01 'i 40 3t >. .,Q BO ... 50 : L-aou 60 -c; Ql ::! CIl70a.. 000,1000.0050,010,05 200 270 01 80 10040 0,' 20104 ,10!50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 8 '00 ,.--"--.- I ,I I I ,I I I "-~I \ I 'm \ I ~I i -' I '\ I I I ~. '\i .i I I I l"- I ........I a.. "'"r-... I "'li r-----~-........r-m )1 i'.-.I i ~ ""'- I Ii) . ,--"0 1000 90 100 80 10 20 70 III 40 ()... Ql a..30 >...c -r. CJl ii ~60 ~50 lL [BOlJLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO,I CONTENT TP-E Y DENSITY LL PI CLASS I GP-C;M CLASSIFICATION a DESCRIPTION ,-------,---+1--' DRAWN BY'J .11. Borrow.Area E IAPPROVED BY:T.I. Test Plt TP-E1 ,~A~E:Dec.1981 RaM CONSULTANT]"INC.•L __.__..o.'_~__~.~tPRCJECT NO,05250G j I I I 1 I 1 I -._ U.S.Standard Sieve OpenlnQ5 in Incoes U.S.Standard Siovo Numb."Hydro",eter o 10 20 50 30 90 80 ...c: 01 'ii 40 ~ >. .0... Gl... \... Cou ,60 ~ Gl U... Gl70a.. 0001 1000.0050.010.05 200 270 QI 80 10040 0.5 20104 5lJ00 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 .---.---._- I I II I I II I I I II I I I~~ I \ \ I \. ~r-.h;]i ""-"- I "I ~ "G.... I r-...':il-...........~l ---. I I"-, r---..r-.. ~ ---0 1000 80 30 100 20 10 90 70 ,., .0 i;50c:: iL ...c 01 Gl 3:60 .. ~40u... Gla.. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY 'rp-El #2 LL PI CLASS GP I DRAWN BY:J_~l1.:. APPROVED BY:BORROW AREA E TEST PIT TP-El DATE:Dec. PROJECT NO. 1981 052506 1\~"f~.~.f J 'r.).~'. J -f ,'-I ----~-) J.,)-OJ 1 1 --]--1 --, U_S_Standard Sieve Openlng~In Inchn u.S.Standard Sieve Number.Hydrometer o 10 30 20 -.c CII••40 ~ >-..c 90 ... 50 :: L...oou 60 -co Gl ~... 70 Q. 80 0001 1000.00150.010.05 200 270 01 80 10040 0.15 20104 IS10!SO 3 2 11/2 1 3/4 1/2 3/8 100 12 9 6 1500 --- [I II I T II I I , .~ '"I :I ~r-.....~ ,"~ I ~ \ I '...r--r-...." ~ I ~-- \ I \ )\f~I ""I'\ ~ eJ 0 1000 80 20 90 10 30 100 70 -~40u... Gl Q. ,., ..c -.c 01 II> ~60 ~50 iL BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. TP..:.E2 #1 LL PI SP CLASSIFICATION 8 DESCRIPTION GRAVELLY SAND WITH SCATTERED COBBLES BORROW AREA E TEST PIT TP--E2 DRAWN BY'J .M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052506 U.S.Slandard Sieve Openings in Inch..U.S.Standard Sieve Numb...Hydrometer 50 90 20 :30 o 10 -.r::.go 40 ~ >...c... II 11\....oou 60 -c: Q,l ~... 70 a. 80 QDO I1000.0050.010.05 2DO 270 QI 8010040 0.0 20iO4 510~ 3 2 11/2 1 3/4 1/23/8 100 12 9 6 000 .......-......- II I I I I ) I ) I ~ "'- 1-41 ........"-I "r-.... '""I ~ "'") ".......fI.-.-) ~--..--.r-...'-e --~-.o10DO 10 90 20 70 :30 100 -.£: a> Q,l ~60 80 >...c ~50 l.l.. ~40u..., a. BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTION SANDY GPJ\VEL WITH NUMEROUS CQBBT,ES AND SCATTE1\ED J::\UlJlJ!J,t.:.d,.,b>ITP-E2 #2 I SAM P LE NO.I 'Ci5;\iTENT~I DENsiTY I LL I PI ~C'.LASS GW BORRUVJ AREA E TEST PIT TP-E2 DRAWN BY:J.M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO,052~5~06-;:----I1 '"~')l l\,J !)?l ")I ""\1 ~1.j'j J )._~,'h)1'\'}--'J -',....t' "'C.'J '1 J 1 .J o 20 10 30 90 -.t= 01 'ii 40 ~ >. .Q 80 50 t'""-ao ,U 60 -c: CIIo... OJ 70 a.. 000,1000.0000.010.00 200 270 Hydrometer 01 8010040 0.0 20104 oD U.S.Standard Sieve Numbers !SO 3 2 11/2 I 3/4 1/2 3/8 100!loo US.Standard Sieve OpenlnQI In Inche. 12 9 6 --I I II I I J I I II I , \ \ \. I!l r<'l "'"I r\ I "e. Q. I ~ I 'a I......~ -""""'Q -~---~ .-0'000 90 30 70 20 10 80 100 >- .Q -~40 l,.l "- OIl tt -~ 01 Ql ~60 ;50c: Ii: BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT TP-E3 #1 Y DENSITY LL PI CLASS GW CLAS:::>IFICATION 8 DESCRIPTION SANDY GRAVEL WITH NUMEROUS COBBLES AND SCATTERED BOULDERS BORROW AREA E TES'l'PIT TP-E3 DRAWN BY:J.M. APPROVED BY; DATE; PROJECT NO.052506 u.s.Standard Sieve Openings in Inches U.S.Standard Sieve Numbers H ydrometor ... .Q o o 20 30 50 90 0- .c 00 '~ 40 ~ '- 4l "'.....oou 60 -C 4l U... III70Q 80 0001 100 O.OO~0.01O.O~ 200 270 01 80 10040 O.~ 20104 !IKl!l0 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 ~oo .---._- I' .---I I I I I I ) ~ '\I '\ , 'r:l ...r. '''''I \ ~) ~ -, ) r--~ -----I'-.. ~ ) ,~;~",...t--~ ~-"" °1000 90 80 100 10 20 70-J:. 00 a> ~60 30 .....~50 u.. ... .Q -~40u... IIIn. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. TP-E3 #2 Y CONTENT I DENSITY LL PI CLASS GW-GP CLASSIFICATION a DESCRIPTION SANDY GRAVEL WITH NUMBEROfTC BORROW AREA E TEST PIT TP-E3 DRAWN BY: APPROVED BY:T.1. DATE:Dec.1981 PROJECT NO.052506 1 "1 J ,~1 ~'.., J ).....):c--,,-.~..,. ")'---J ~"],,_.~)~)~-3 '-'1 -'.-1 ---1-1 u.S.Srandard SIeV8 Openln~s In Inches u.S.Standard SleveNumber~H ydrameter c:; 41 ~ Q) 70 a. 10 20 o 90 30 ... 50 Ql~oou .. .s;; CII ii 40 ~ >. .Q 80 60 000/00 0.0050.010.05 200 270 01 80 10040 _0.5 20104 15K)50 3 2 11/2 I 3/4 1/2 3/8 /00 12 9 6 500 .------._- I II I I I I I I ! I ) I ) \ '\I '\ I)10-~1'-- "'"!'.---'----)--..... f'0-......~, --)a:.....I-...... -----r-t-t--r--.,---0 1000 90 70 100 80 20 10 ~50 u.. 30 ... ~40 I.).-Qla. >..c .. .r::; CII III ~60 BOLLDERS COBBLES I GRAVEL --1 SAND ~FINES :==J Coarse I Fine Coarse I Medium I Fine Silt Sizes IClay ~~ SAM PLE NO.I CO;.tTENT"I DENsiTY I LL I PI I CLl\SS CLASSI F ICATION a DESCRI PTION I 'TP-E4 #1 1_I I I I GP I SANDY GRAVEL \ri1ITH NUMEROUS COBBLES~AND~TTEB.E.11_.13illlLDERS .--- I I I I I I I I APPROVED BY:T.I. PROJECT NO.052506 DATE:Dec.1981 BORROW AREA E TEST PIT TR-E4 I I I I I ._.----t[L __-'-_--====::::~~;;;;~;;;;;;:I---i DRAWN BY:J.M.I I I I II u.s.Standard Sieve Openings in Inelles U.S.Standard Sieve Numbers Hydrometer >..c o 10 30 50 20 -.c '"Qj 40 ~ 90 ... III II>.....oou 60 -c Q) ~ Q) 70 a.. 80 0001'000.0050.010.05 200 270 01 80 10040 0.5 20104 5o50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 ~oo .---.-~-._--I I I I I I ) ) 't;). .", I '\!\ - I ~-, I r"a ~ "")I--:i)...---"i--.. l-t--I---"""''''0 1000 -&. '".. ~60 90 100 80 70 10 20 30 >. .Q -~40 <.> "- IIIa.. Q;50cu:: BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CLASSIFICATION a DESCRIPTION _._~..._-'----"---------~-_.._.._.,--,------ TP-E4 #2 SAJ'lDY G~~!,WITH NUMEROUS CPB~LES :Nil)SCATTE,REIL]?OULDERS I BORROW AREA E TEST PIT TP-E4 DRAWN BY:__.l...ll/.......l!::I'L.1 ---.II APPROVED BY:T.I . DATE:Dec.1981 PROJECT NO.052506 1(~ ~--1 .~~~)J 1 '~-)))-~C]"}.''']'\ >. .Q o o 30 20 90 "-50 II)III Q ou 60 -c 11l l.>... OIl 70 11. -s:::. CJI 'i 40 ~ 80 0001 100OOOtl0.010.05 200 270 H ydrom,t., 01 80 10040 O.tl 20104 tl() u.S.Standard Slev,Number s tlO 3 2 11/2 I 3/4 1/2 3/8 100tloo US.Standard Sieve Openings in Inches 12 9 6 .---.---._-,,II I I',I I I , , I '\ I \ \ I \ \ ) )~ f', )"-~ "-)I......,~ ~r-----. I--I ~ .......---------"'. ,,0 1000 90 80 70 20 10 100 30 •50cu:: >. .Q ... ~40 I.> "- II> 11. -~ CJI i~60 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. TP-E5 #1 LL PI GW-GP I I I I I I I ------I BORROW AREA E TEST PIT TP-E5 DRAWN BY: APPROVED BY;T.I. DATE:Dec.1981 PROJECT NO.052506 u.s.Standard Sieve Openings in Inche.U.S.Standard Sieve Numbers H ydrameter >...a... CIl 11\...oo U 20 30 o 10 50 -c <l> ~ '"70 a. -.J:: 0' 'il 40 ~ 80 90 60 200 2108010040201043211/2 I 3/4 1/2 3/8129 6 It I I .-.- II I I I II '~ ~ I , I'---- '"~ 1\ "'- ~ I f\ ) f'\ --I \ ) I\. ~ '"I ")€ 10 100 20 80 -.J:: 0' CIl ~60 >...a Q;50c: u:: 70 90 30 -~40 (.)... CIla. 0 1000 ~oo 100 ~Kl 5 0.5 Oi 0.05 0.01 0.005 0001 100 BOlLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. TP-E6 #1 y CONTENT I DENSITY LL PI SM CLASSIFICATION a DESCRIPTION SAND WITH SOME GRAVEL. BORROW AREA E TEST PIT TP-E6 DRAWN BY:J .n. APPROVED BY:T.I. DATE;Dec.1981 PROJECT NO.052506 -~)~1 \l )I ~).c .~"]'._J "'1 .'.'.')-1 -..."'1 ').~., J US.Standard Slev.Openings in Inches U.S.Standard 51.v.Number a Hydrom.t.r o o 30 50 ....c 01 iii 40 ~,.., .Cl 20 80 90 ... Q> '"...oou 60 ... C QJ ~ QJ 70 a. 0001'000.0050.010.05 200 270 01 80 10040 o.~ 20104 ~()~o 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 ~oo .---"11 I I I I II ) ~ r- i\ \. \ . '0 I ""I \, \. "K ) &....r-....f~ t,··--=---r--.--.r-.---...,..'"0 1000 90 10 100 Qj 50c: ~ 20 30 70 80 ,.., .Cl ....c 01 Q> ~60 ... ~40o... Q> Cl. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT y OENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION 'T'P-E8 #l GW BORROW AREA E TEST PIT TP-E8 DRAWN BY' APPROVED BY'T.1. DATE:Dec.1981 PROJECT NO. us.Standard Sieve OpenlnQ'in Inche,u.S.Standard Sieve Numbera H ydrameter >. .Q o o 20 30 50 90 -.c 00 ii 40 ~ '-Q) III.....oou 60 -c Q) u... Q) 70 D... 80 0001 1000.0050.010.05QIO.!l!lK)!50100!l00 12 9 6 3 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 -----r-----~I I I I I II ~ "\ .- 1""-I I ~ '\ '\. f\. '"I I\. '\ )1\ \I I \ ~ ) 1\ I r'\.. ~ ......... .-~--- ~~ - 10 0 1000 20 -.c 00 CIl ~60 90 70 30 100 80 >. .Q -;qo u... CIl ll. ~50cu: BOLl..DERS I COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes SAMPLE NO.CLASSI F ICATION 8 DESCRIPTION 'T'F'-E8 #2 GRAVELLY SAND DRAWN BY'J .M. I APPROVED BY'T.I. DATE:Dec.1981 BORROW AREA E TEST PIT TP-E8 •,,~•••w ..~~,~..,~,"No i I PROJECT NO.Q2.?.~~ 1~\., ~]..•{'J ]--1 '1 ._---,J --~} " us.Standard 51 •••Openings In Inches U.S.Standard Si •••Numbers Hydrom.t.r o 10 30 20 -.c '"i 40 ~ >.. .Q 90 50 80 .. CIl VI..oou 60 -C <IIu... CIl700.. 0001 1000.0050.010.0.501O.SsK>so100soo 12 9 6 :3 2 11/2 I 3/4 1/2 3/8 4 10 0 40 80 100 200 270 I I "';--I I rrr---"""- ............. I ) I I ) ) ): ~ 10 01000 70 90 30 80 20 100 -~40u... III 0.. -.<= 0' •~60 ""..Cl i 50cu: BOLl.DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes I SAMPLE NO.CON"TENT"DENSlTY I L=±PI DASS ._.C',A3SIFICATION a DESCRIPTION I TP-E9 #1 I M-cQ:LT_~ITH SOME _T0 ~RACE CLAY AN;)TRACE SAND I BORROW AREA E TEST PIT TP-E9 DRAWN BY: APPROVED BY: DATE:Dec • PROJECI NO. T.1. .ll8L__ us.Standard Sieve OpenlnQs in Inches U.S.Standard Sieve Numbers Hydrometer '-.... '--oo U o 20 10 30 ...c CI> ~., 70 a. 50 -£:. CIl ii 40 ~ >. .Q 60 80 200 270801004020104;3 2 11/2 I 3/4 1/2 3/8129 6 .---.--~.~- I r II I I I \....., G>-""~b -- I r-lil. --,..... 1\ \ \ , I \ ~ )\I'\ I \ ), 100 20 30 80 90 70 >. ..Q ....c CIl ~ ~60 '-~50 ii:... ~40o '-.. Q. 10 90 0.01 0 1000 !loo 100 !lO ()!l O.!l 01 0.05 0.005 000,100 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI C CLASSIFICATION a DESCRIPTION TP-E9 #2 SM SAND WITH SOME GRAVEL AND SILT AND SCATTERED COBBLES BORROW AREA E TEST PIT TP-E9 DRAWN BY:J .M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052506 1 ":n ""'ill.IJI ::q 1 ~1 ~~, "1 ]~-1 ~-l f 1 ")~-'-'-l J 1 c''-~"J -1 1 1 US.S1ondord Sieve Opening,in Inch••u.s.Stondord Sieve Number'Hydrometer >. .Q o 10 30 20 90 -.c C1I ii 40 ~ 80 50 G;.....oou 60 ...c Q) u...v70a. 000,1000.0050.010.05 200 210 01 80 10040 0.5 20104 51050 3 2 11/2 I 314 1/2 3/8 100 12 9 6 500 I JI ,II I'I .-II -1-',-I' I \ 1 ""a ~ Ia. ~ - I f'-..-.h -, I ~ I-....... I " ) "'""'-~ ~ -, -- I II I I I - ~0 1000 30 70 100 80 90 10 20 >...c -&. 0'.. ~60 -~40 l)... CIla.. •50cu: OOLl.DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTIONSAMPLENO.I CONTENT TP-E9 #3 Y DENSITY LL PI CLASS GM SANDY GRAVEL WITH C BORROW AREA E TEST PIT TP-E9 DRAWN BY:J .M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO. u.s ..Standard SI,~,Openings In Inch ..u.S.Standard Sl,~,Number,Hydrom,ter o 20 10 30 50 -.c 0' iii 40 ~,., .<:I 90 80 ... ".....oou 60 -c CI><.>.... "70 a.. 0001 1000.0050.01O.O!! 200 270 01 8010040 O.!! 20104 15K)!!O 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 !!OO .- f I II 1 1 I 1 I )<1 'G '\ ) "\ I ,, )~ l"- )~e.... .........r-..:I --'1-- r-..1"-<;;) "" I ""I, ~ ~0 1000 10 90 80 70 100 30 20 ,., .Q .... ~50 u:: -.c 0' 'ii ~60 -~40 <.>... "Q. I COBBLES GRAVEL SAND FINESBOLLDERSCoarseFineMediumFineSiltSizes SAMPLE NO.CLASSI F ICATION 8 DESCRIPTION TP-E10A #1 SANDY GRAVEL WITH SCATTERED COBBLES BORROW AREA E TEST PIT TP-E10A DRAWN BY;J .t1. APPROVED BY;T.I. DATE;Dec.1981 I PROJECT NO.052506 ]~.~1 I ~::j "'1 '1 '~..~]1 J ~ t ···~·l ,....'J 1 1 1 us.Standard SllvI Open/nQs in In chI'U.S.Standard Slevl Number.H~dramlt.. o o 20 30 90 -~ 01 i 40 ~,. .Q... 50 III.. '- CIou 60 -C IIIo"-III 70 a.. 80 Qoo/loo0.0050.010.05QI0.551050100500 12 9 6 :3 2 11/2 I :3/4 1/2 :3/8 4 P 20 40 80 /00 200 270 "I / I I ~ '" I \:\ 1\ \, \ \, I ~ I \ \ 1\ •I 'e .-0 1000 30 20 10 90 70 80 100 ,. .Q '-~50 u:: -&.co 'i ~60 -~40o "- IIIa.. BOll.DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. TP-E10A #2 LL PI CLASS SM CLASSIFICATION a DESCRIPTION SAND WITH SOME SILT BORROW AREA E TEST PIT TP-E10A DRAWN BY: APPROVED BY: DATE:Dec. PROJECT NO. T.1. 1981 052506 US.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer ............... Clo U o o 30 20 50 90 -.c. '"i 40 ~ >. ..Q ...... C ClI ~ OJ70a.. 60 80 0001 100 OOO!l0.010.0501O.!l!lKl!lO100!l00 12 9 6 :3 2 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I I II I II I I r\ I f\ "'-Gl \ I \: \, I ~ I \ \ \t---- I f'/. )""I "ID. I 1'---, ~"'- )~I r-..."v.> .........r-........ ~ - 10 0 1000 :30 -z;;; '"OIl ~60 90 100 70 20 80 ..... ~50 u:: >. ..Q -;40 <.>..... '"Q.. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTION -----"------------------------11 PILLSAMPLENO.I CONTENT I DENSITY CLASS I Tr-EJ.OD #1 I I I I I GP I SANDY GRAVEL I BORROW AREA E TEST PIT TP-#10B DRAWN BY:J_:M.I APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052 "~~1 ~1 .,~-]1 -""~l -1 1 \---~l 1 '-1 1 "1 u.s.Sfondord Sieve Op8nlnQs in Inches u.S.Sfondord Sieve Number S Hydrometer o o 30 20 50 90 ... ~ 01 i 40 ~ >. ..Q "-II> III,- C Cu 60 ...c II>u "-OJ70a.. 80 12 9 6 3 2 11/2 I 3/4 1/2 3/8 4 ,20 40 80 100 200 270 I II I I 1 I r-... ~ \ I \:\ \ ~~ , 1\ \, \ I \ 1\ ) I'" ) )I ,10 90 30 70 20 80 100 >. ..Q ... ~ 01-ii ~60 ... ~40u "- lI>a.. "-~50 u: 0'000 500 100 50 10 5 0.5 01 0.05 0.01 0.005 0001 100 BOlJ...DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine •FINES Silt Sizes SAM P LE NO.I CONTEN'·t I DENsiTY I LL I PI I CLASS CLASSIFICATION 8 DESCRIPTION I TP-E:ll #1 I I I I I--=SM=-=-------I-I---C::S=IL=T~Y~SA~N~D~. BORROW AREA E TEST PIT TP-E11 DRAWN BY' APPROVED BY;T.I. DATE:Dec.1~81 PROJECT NO.052506 US.Standard Sieve Opening.in Inches U.S.Standard Sieve Numbers Hydrometer >. .0.. "OIl L..oo U o o 20 30 50 -c "~ "70 n. 90 -~ t:JI i 40 ~ 80 60 0001 100 0.0050.010.05 200 270 01 80 10040 0.11 20104 11Kl110 3 2 11/2 1 3/4 1/2 3/8 100 12 9 6 1100 --._- ----j --.- I I ,.- I -- I'I I ,,II --:"-I '" , ~t'- - ) 1"""Gl. - 1'- 'hit - ~ --l I "- I f'. 1"'--........ ---....,--- I I "I'e -- I '"~ ...J ) '-' jt> 0 1000 90 80 70 30 20 10 100 >. .0 -s;;; t:JI "~60 .. ~50 u:-~40u L.. "0.. BOLl..OERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTE~T"I D~~SYTY I LL I PI I CLASS CLASC'FICATION a DESCRIPTION I TP-Ell #2 I I I I IGP-GM I SANDY GRAVEL WITH TRACE SILT ~D SCATT.2RED __~Q!3..BLE_-2 __.bNJ2J?Qu..LDERS I BORROW AREA E TEST PIT TP-Ell DRAWN BY:J .M. APPROVED BY:T.1. DATE:Dec.1981 PRO.IECT NO.052506 1 l ,I "1 J I ~l ~1 ~-~1 ~~-J 'J ~--]-~1 "~]] o o 30 -r.... i 40 ~ >-.0 90 20 80 "-50 CI)Ul...oou 60 -c CI) ~... 70 Q. 200 270 H ydrom.t.r 80 1004020104 U.S.Standard 51 •••Number 5 3 2 11/2 I 3/4 1/2 3/8 us.Standard 51 •••Opening.in Inches 12 9 6 .--.----- I II I I I I I I I' I : ll. "(l ""'-"~ i'<;t ~ "i' ) r-....a.. I"--.!'-.., ~ )"t--m Ii'"- l:i:..........-~ 100 30 80 90 70 10 20 -~ ~.. ~60 -;40 u.....a.. >-.0 :.50c: iL: 0.0101000!l00 100 !IO Kl !I O.!I 01 0.05 0.005 0001 100 BOlLDERS COBBLES Coarse GRAVEL Fine .SAND Medium I Fine FINES Silt Sizes SAMPLE NO.I CONTENT y DENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION TP-E12 #1 GP-GM SANDY GRAVEL WITH TRACE SILT AND SCATTERED COBBLES AND BOULDERS BORROW AREA E TEST PIT TP-E12 DRAWN BY:J .M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052506 U.S.Standard 51 •••Openlnos in Inches U.s.Standard St.v.Number I Hydrometer o 90 10 20 30 -.c 01 ii 40 ~ » ..Q 80 ... 50 ~.....oou 60 -c (\) ~ (\) 70 CL .--v ~iL.I I'.\;,..~~I'~oJ,'"~'v ~v ~v u~I~V "'"v...."V I I I "II I I 1 II ""~r---.. I ......., 1\ \ \ \ 1\ 1 \ ~ I ) ) ," 10 30 -.t= 0- lD ~60 70 ,... ..Q 20 100 90 80 -c:~40... lDn.. Qj 50c:u: 0.01 0 1000 !l00 100 w Kl 5 0.5 01 0.05 0.005 0001'00 BOu..DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO I CO;.tTENT"I otN'SiTY I LL I PI I CLASS CLASSIFICATION 8 DESCRIPTION I TP-E12 #2 I I I I I SM I~ILTY,SAND WITH TRACE"GRA~J:_.:At:J.R ..CI"AY -"._.----t (FIELD GEOLOGIST NOTES TRACE ORGANICS) BORROW AREA E TEST PIT TP-E12 .~~1 ~j 'Ii J 1 1 1 -J J,J ,i -1 ---I '1 1 c~]"'~"l ,··..-·-1 1 '-l --o-1 ...._]"-1 --1 '-"'-1 ._) >. .Q 30 o 10 20 -.c::. 0' Gi 40 ~ 50 ~CII '-oou 60 -C ellu "-ell 70 a. 80 90 000,1000.0050.01O.O~ 200 270 H ydrom.ter 01 80 10040 O.~ 20104 ~Kl U,S.Standard SI.v.Numb.rs ~O :3 2 11/2 I 3/4 1/2 3/8 100~oo US,Stondard 51 .....OpenlnQs in Inches 12 9 6 ITTT I I I 'I -+- I I I I II II T I V- 0 1'1 I I T ~.1111 T I .- I ,-,-'1-I T I I I I 1 II I I 11 1 1 I I - f-., ~. - ~ I 1'--1--- 'G - '\ I --, ) '\ -~ I - \... "\: - ) '"I!J I -, .- II I _. I I I I - II -..- ---J01000 100 30 10 70 90 20 80 -~40 u "- IIa. -.c CI' ~ ~60 >. ..Q Ii 50cu: BOll.DERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION TP-E12 #3 SM SAND WITH SOJVlE SILT I TRACE GRAVEL AND SCATTERED COBBLES "'0...I I I I I I I I BORROW AREA E TEST PIT TP-E12 DRAWN BY;_._- A PPROVED BY ; DATE;Dec. PROJECT NO. 1981 052 T.1. u.s.Standard Sle"e Openings in Inches U.S.Standard Sieve Numbe ..Hydrometer >. ..Q o 10 20 30 50 -£; 01 Gl 40 ~ 90 80 .. Gl.....cou 60 -C Glu.... Gl 70 a.. QOOI'OO0.0050.010.05QjO.!!!!10!lO100!!OO 12 9 6 3 2 11/2 I 3/4 1/2 3/8 i 10 20 40 80 100 200 270 I I "r-,.~II I I I II )~ "'- "': \ \ \ \ ,\ \ I \ \ I 1\I'\ ""-t'-.. l,.. - 10 0 1000 ii 50c: u. -£; 00 "Q; ~60 90 20 70 80 30 100 >. ..Q ~qoo.. Gl Cl. I I I r '""'';''''''I .:INES ~ Silt Sizes .=JCla).SiZ€5 GRAVEL I CJ\Pdr'\ BOLLDERS I COBBLES I I Coarse I Fine ICoarse I Medium ~ SAMPLE NO.~LL I PI I CLASS CLASSI F ICATION a DESCRIPTIONDENSIT~ TP-E14 #1 ~P-SM I SAND WITH TRACE SILT BORROW AREA E TEST PIT TP-E14 DRAWN BY: APPROVED BY; DATE;Dec. PROJECT NO. T.1. 1981 052506 ,1 1 11 ),:1JJj ·...]1 '1 1 -1 ····-1 .-''1 "-1 ----,-'1 --::'1 "--::J )'1 .) u.s.Standard Sieve Openlnlll In Inches u.S.Standard Sieve NUMbers H ydraMeter o 20 30 10 90 -~ '"i 40 :t >, .Q 80 .... 50 ~ oou 60 ....c: Q) ~ '"70 a. 0001 1000.0050.010.05 200 270 QI 80 10040 0.5 20104 5o50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 .--..-. I I I I I I I , I' ""'", It<>--ii .........Q.... I "I ~ I 'bl .............r-..... I ~I Q., ~I ~ ""'0- <:1 OKXlQ 90 >, .Q 100 :30 20 \0 80 70 .... ~50 u:: ;40 u.. IIa. -~ 01 II ~60 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO y CONTENT I DENSITY LL PI CLASS CLASSIFICATION 8 DESCRIPTION TP-E14 #2 SP GRAVELLY SAND W/TRACE SILT,AND SCATTERED_COBBLES J\ND_~qULDERS I PROJECT NO.052506 BORROW AREA E TEST PIT TP-E14 DRAWN BY: APPROVED BY: DATE:Dec.1981 J.M. T.1. US.Slandard Sieve OpeninQs in Inches U.S.Slondord Sle.e Number S H ydromeler >. .Q o 20 30 10 -.c: ~ ii 40 ~ 90 80 .... 50 OIl'"....oou 60 ...c OIlu "-OIl 70 c.. 0001 100 0.0050.010.0!l 200 270 or 80 10040 O.!l 20104 !lKl!lO 3 2 11/2 I 3/4 1/2 3/8 100 IZ 9 6 !lOO 20 30 80 10 90 70 0 1000 100 ~50c >. D ....c: ~a; ~60 ... ~«) u "- OIlc.. u: BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. 1 y CONTENT I DENSITY LL PI CLA GW CLASSIFICATION 8 DESCRIPTION GRAVEL WITH SOME SAND AND SCATTERED COBBLES AND BOULDERS I BORROW AREA E TEST PIT TP-E15 DRAWN BY:J .M. APPROVED BY:T.1. DATE:Dec.1981 PROJECT NO.052506 n ;]~(~'I 1 n ~]';1 1 1 1.,,,;; ---J -'1 ]-----~l ~--]--1 "-]---1 --------1 ----1 1 ----1 ---eel --- US_Standard Sleyo OpenlnQs in Inches u_S.Standard Sieve Number I Hydrometer >. .Q o o 30 50 ~ '-oo U 90 c Qlo.. Ql 70 Il. 20 ....cco Ii 40 ~ 80 60 0001 1000_0050_010_05 200 270 01 80 10040 O.~ 20104 eKl~ 3 2-11/2 I 3/4 1/2 3/8 100 12 9 6 eoo - I I I I 11 I 1 I --II I : r--Q. ~ t-- -'" "-f' ~ "\. I l f'-- I """)"'-I~ Ie - h- r--e ---"-~f"0 1000 20 30 80 10 90 -s::.co -ij ~60 70 -~40o '- Qla.. 100 >. ..Q ~50c Ii. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT Y DENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION TP-E16 #1 SP GRAVELLY SAND WITH SCATTERED COBBLES AND BOULP]';;RS I BORROW AREA E TEST PIT TP-E16 DRAWN BY:.J.n.I APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO_052506 U.S.Standard Sle.e Openings in Inch..U.S.Standard Sieve Number,Hydrometer o o 20 30 50 -~ '" 40 ~ >. ..Cl....., '"...oou 60 -C I1lo... I1l 70 a.. 80 90 0001 1000.0050.010.0501O.!l!lK)!lO100!l00 12 9 6 3 2 11/2 I 3/4 1/2 3/8 10 20 40 80 100 200 270 II I I '------II I I ~ .......1'-.. "'I'--. ,'":, ""I'/) I I I I )I '.., -~=±= 10 °1000 20 -.s::; ""'"~60 90 70 30 100 80 ... ~50 u:: >. ..Cl ~40o....., a.. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES ~ Silt Sizes JClay sjZeS SAMPLE NO. TP-E17 #1 LL PI CLASS SM-MH CLASSIFICATION a.DESCRIPTION SANDY SILT WITH SOME TO rBA(::E_CLAY______~ (FIELD GEOLOGIST NOTES SOME TO TEACE ORGANICS) BORROW AREA E TEST PIT TP-E17 DRAWN BY; APPROVED BY;T.I. DATE:Dec.1981 PROJECT NO.052506 ~',j 1 ~'1 ~1]]11 i1 1.J ,J ! ~--'J '--1 '--1 -1 ---~J 1 ---']'------1 ·~----l -'--J '1 '---1 ']--'~I --1 1 US.Standard SI.v.Openings In Inches U.S.Standard SI.v.Numbers H ydrom.ter o 10 30 ... ~co i 40 3t >. .0 20 90 50 ttil...oou 60 ...c CI>.., '-'"70 a.. 80 0001 1000.0050.010.05010.55o50100500 12 9 6 3 2 11/2 I 3/4 1/23/8 4 10 40 80 100 200 270 I II I ,HI I I II '\ I "'\ )~ \ I ~ \ ,\ I 10 )I -,0'000 10 70 20 90 100 80 >. .Q -~co Ql ~60 -~40..,.. Ql Q.&> ~50 LL 8OLLOERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT TP-E17 #2 y DENSITY LL PI 5M ,S ILTY SAND CLASSIFICATION a DESCRIPTION BORROW AREA E TEST PIT TP-E17 DRAWN BY: APPROVED BY;T.I. DATE:Dec.1981 PROJECT NO.052506 U.S.Standard Sllvl OpeninQs in Inches U.S.Standard Silve Numbers Hydrometer o o 20 30 90 -.c. Cl> iii 40 3= >..a 50 tIII...oou 60 -c CI>u... CI> 70 Cl. 80 200 2708010040201043211/2 I 3/4 1/2 3/8129 6 .---.---._- I I II I I I I I I 1 1 : l?>- I '-"", I'\. r\ ~ '"'1il I I ~ I ......,,,, I 'I'--.. ~ )~I t"- .:r--a ............--~ 80 70 100 -.t:: at II ~60 90 >- ..Q 30 20 10 ~50cu::-;40 u.....a. 0 1000 ~oo 100 ~10 ~O.~QI 0.05 0.01 0.005 0001 100 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.DENS~LL I PI ~LASS TP-E17 #3 GP-GM CLASSIFICATION a DE~CRIPTION ~ SANDY GRAVEL WITH TRACE SILT,SCA'I'TERE!LCQlillLES AND BOULDEES-'-_~_L~ BORROW AREA E TEST PIT TP-E17 DRAWN BY:J APPROVED BY:T.I DATE:Dec.1981 PROJECT NO.052506 'l ~.~~1 .,i ~"I l,.1 --]1 ---~)--J 1 --']-~'---)--1 ---1 ~I ]--------]----1 -1 ] us.Standard Sieve OpenlnQs in Inches U.S.Standard Sieve Number S Hydrometer o 90 10 20 30 ...c. Cll Cii 40 ~ >. ..Q 80 "- 50 ~...oou 60 .. C IIIu.... III70Q. 0001 100 0.0050.010_05QJ0.55Kl50100500 12 9 6 ~2 11/2 I 3/4 1/23/e 4 10 20 40 eo 100 200 270 J I r\.II I I II I I '\ i\ \ I '\ \ i\. ~ \ I I', r'-. ""r"-.)'" -- )r"-. """- ) """"'G ~ ~ 0 10 0 1000 30 70 20 80 100 90 ~50c U- >. ..Q ...c. Cll III~60 .. ~40o... III Q. BOLLOERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI CLASS CLASSIFICATION a DESCRIPTION TP-E18 #1 GP SANDY GRAVEL (FIELD GEOLOGIST NOTES SOME ORGANICS) BORROW AREA E TEST PIT TP-E18 DRAWN BY: APPROVED BY: DATE:Dec. PROJECT NO. U.S.Standard SI.v.Opening.in Inch ••U.S.Standard SI.v.Numbers H ydrom.'.r >, .Cl o 20 .... 50 '"III....oo U 30 10 90 ~c: '"~ Q) 70 Cl. 60 -.r= 00 'ij 40 ~ 80 0001 1000.0050.010.05 200 270 QI 80 10040 0.5 20104 5Kl!IO 3 2 11/2 I 3/4 1/2 3/8 100 12 9 _6 500 I I ""I II I I .- t... - I ~--- I I I II ~-'- I I ~ ) I - ""G\ 1<: \ I \ \ I , ~ I "\ \ ) E !l .- 1 I 1 r I I I -- I ,I I I J I I I --I 0 1000 i;50c: u. 80 -.r= '"'Ii ~60 70 90 :30 100 20 10 >- .Cl -~40o..... Cl. BOLLDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CON"TE~~<'I DENsiTY I LL I PI 10Tn""CLASSIFICATION B DESCRIPTION I TP-E18 #2 I , , , I SM I SAND WI'rH SOME SILT/,TR}\C~__SPAV~L A~_~C~T:r_~~-.£?~BI_,E_<S _ BORROW AREA E TEST PIT TP-E18 DRAWN BY APPROVED BY: DATE:Dec. PROJECT NO. ~1j 1 1 j ~]'F,l B ,.,.4 ~i1 1 ]~~~l ~"1 1 --']-1 1 ""--"-1 ~~-l "]---] US.Standard 51 •••Openings in Inches U.S.Standord 51 •••Numbers H ydrom.ttr o 30 10 20 90 80 "- 50 ::: ~aou 60 -<: Q) ~., 70 Q. -.s:; 01 'j 40 ~ >. .Q 0001 100 0.0050.010.05010.55(l!lO100500 12 9 6 3 2 11/2 I 3/4 1/23/8 4 10 20 40 80 100 200 270 I"'---d ,II I I I I' I \ \ )\ \ I 1\ I \, \ ) 1'\ '\ ) a... .........r---....) "~ )~IIll. "'li1 r--.- ~"'" "~0 1000 30 20 10 80 70 100 90 "'".Q -.c 01 'i ~60 -~40o ~ "Q. ~50c:u:: BOLl.DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes I mv,,,'''"..,lJnY I LL I PISAMPLENO.CONTENT DENSITY Ie CLASSIFICATION a DESCRIPTION I TP-E18#3 I I I I I GP I SANDY GRAVEL._ BORROW AREA E TEST PIT TP-E18 DRAWN BY' APPROVED BY''T'I DATE'Dec.1981 PROJECT NO.0525 US.Staftdard Sle ••O~nlngs in Inchn u.S.Standard Sle.e Number s Hydrometer o 30 10 20 90 80 -.J::.co 'i 40 ~ "'"..Q... 50 411... L- Cou 60 -<: 411o L- a! 70 lI.. 0.001'000.0050.010.05 200 270 QI 80 10040 0.5 20104 5()50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 .---.-_...._- I I II I I 1 I I ",. I ""'"I "'-iii '\ "~, i I ~-........ )~I~ r--r--., "W I"'----r-...... I'" -0 1000 10 90 -.J::. CIl 'ij ~60 30 20 100 80 70 "'"..Q -~40o L- II lI.. ~50 u: BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Sill Sizes CLASSIFICATION a DESCRIPTION SANDY GRAVEL WITH SCATTERED COBBLES }\ND BOULDERC'GP PILLSAMPLENO.I CONTENT I DENSITY TP- BORROW AREA E TEST PIT TP-E18 DRAWN BY:J .M•I APPROVED BY:T.1. DATE:Dec.1981 PROJECT NO.052 J ~'A:il ~1 .~1j '\1), ~J ",)C'}]--1 .,--]1 "J 1 1 J -1 U.S.Standard Sieve Openings in Inch ••U.S.Standard Sieve Number,H ydrameter o 30 10 20 ....c 01 '~ 40 ~ >. ..Q 90 "- 50 ~ "-oou 60 ...c:: Ql ~ '"70 Cl. 80 QOO,IOO0.0050.010.05QIo.!!!lo50100!l00 12 9 6 3 2 11/2 1 3/4 1/2 3/8 4 10 21 40 80 100 200 270 --I I II II r-~I I I \-- r\ I \, ~ \'-\ '\ \ \ ) If&) ,- ) )I -- 10 °1000 :30 20 90 70 100 80 -~40u..... Cl.. >. .0 t 50r:: iL -.c 01'a; ~60 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Sift Sizes SAM PLE NO.I CONTENT TP-E19 #1 y DENSITY LL PI CLASS SM CLASSIFICATION a DESCRIPTION._------_.'-_.-..,.,-_..." SILTY SAND WI'I'i:!TRACE CLAY,_.._, (FIELD GEOLOGIST NOTES TRACE ORGANICS) BORROW AREA E TEST PIT TP-E19 DRAWN BY: APPROVED BY:T.1. DATE:Dec.1981 PROJECT NO.052506 u.s.Standard Sieve Opening.in Inch ..u.S.Standord Sieve Numbers Hydrometer o 10 20 30 -s:: t:ll Gi 40 3: >..c 50 .. 0» III....oou 60 -c C1l ~cu 70 CL 90 80 0.001 100 0.0050.010.0501O.~~Kl00100~oo 12 9 6 3 2 11/2 I 3/4 1/2 3/8 4 ~20 40 80 100 200 270 I I II I '-I--. I I I II ) \ \ ) 1\ I \ \ \ \ '\ \ )'\ \ ) )I~, -- ~ 10 °1000 30 100 70-s:: t:ll 0» 3:60 80 90 20 -~40o...... CL >. .Q ....~50 u: BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.Y CONTENT I DENSITY LL PI CLASS CLASSIFICATION B DESCRIPTION TP-E19 #2 SM SAND WITH SOME SILT I I I I'I PROJECT NO.052506 APPROVED BY_:T.I. DATE:Dec.1981 BORROW AREA E TEST PIT TP-19 I I !I I r DRAWN BY:J .M~--I 1 1 ~1 '\:~,lli-,J J 1 '1 ~·'-l 1 '~l ._-.)1 -.-J 1 1 -'1 /~.'1 ]·'1 1 US,Standard Sieve Openings in Inches u,S.Standard Sieve Numbers Hydrometer '"'.a o o 20 30 .. ~co ii 40 ~ 80 90 ... 50 GlIII...oou 60 ..<:: Glo '-Gl 70 CL 12 9 6 3 2 11/2 I 3/4 1/23/8 10 20 40 80 100 200 270 I I I I -~I I II '"'"r-..:\a I \ \ ~ ~ I I )I I10 80 20 70 30 90 100 '"'.a ~50 it: ...c ~ 'Ii ~60 .. ~40o '-.. Cl. 0,010 '000 500 100 50 K)5 0,15 01 0,05 0,005 aooi lOO BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CLASSIFICATION B DESCRIPTION TP-E20 #1 SANDY SILT vHTU TRACE CLAY .._.__=-~-_-.-_-----------------, (FIELD GEOLOGIST NOTES TRACE ORGANICS) BORRDW AREA E TEST PIT TP-E20 DRAWN BY:J.M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO,052506 u.s.Standard Sieve Openin~s in Inch••U.S.Standard Sieve Numbe ..Hydrometer >. ..Cl o 20 30 10 "- 50 ~....oou 60 -c.. ~ OJ 70 a.. 90 -.l::ao Gi 40 ~ 80 000[1000.0050.010.05 200 270 01 80 10040 0.5 20104 5.050 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 .-y I I I !II JII' I .. "\ - \ - ~ \ \)\ -- 1\) N ~ - I -~ l.I>.. r-----. ) '.'t--- I~r----. 11~ :> II°1000 90 80 70 20 10 100 30 >. ..Cl .. -'=~.; ~60 ....~50 u..-~40o......a.. BOl1...0ERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CLASSIFICATION B DESCRIPTION I TP-E20 #2 GRAVELL¥211ND WITH TW\CECLAY BORROW AREA E TEST PIT TP-E20 DRAWN BY: APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052506 j :;\]."'l ~1 "I"j , -]]]F]1 )1 ~J ]]<·~-·.1 ,-~-)1 --]1 ] u.s.Standard 511.1 OpenlnQs in Inches U.s.Standard 511.1 Number S Hydrometer a o 20 30 80 -.c '"iii 40 ~ >...a 90 ... 50 ~ oou 60 -c <U ~ OJ 70 a.. QOO,'OO0.0050.010.05 200 270 QI 80 10040 0.15 20104 1510150 3 2 11/2 I 3/4 1/23/8 100 12 9 ~6 1500 20 0'000 10 30 70 80 90 100 ~50c u.-~40u...., a.. >. "Q -.&:. 0''; ~60 BOLLDERS I COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes SAMPLE NO.CLASSI F ICATION a DESCRIPTION TP-E20 #3 SILTY SAND WITH TRACE CLAY AND GRAVEL AND SCATTERED COBBLES PROJECT NO,052506 BORROW AREA E TEST PIT TP-E20 DRAWN BY: APPROVED BY; DATE:Dec.1981 J.M. T.1. u.s.Standard Sieve OpenlnQs in Inches U.S.Standard Sieve Numbers Hydrameter o o 30 20 .... or: '"Gi 40 ~ >..a 50 80 90 .... Q) IIIoo l> 60 ....c Q) ~ OJ 70 [L 200 27080100402010432i1/2 I 3/4 1/2 3/8129 6 ~.-~.~ I'I I I I I I 1Gl. ""'", 'Cl).k -- I '"~"-"'r.. "~\"""@... ~r---i ~~- )Go r-.. II'-G ........... .............~I'-......It:. 20 ....c 0- Q) ~60 100 80 90 30 70 10 ~50c: i.L >...co ... ~40u.. Q)a.. 0 1000 ~oo 100 ~10 ~O.~01 0.05 001 0.005 0.001 100 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTEN~?I DENsiTY I LL I PI I CLASS CLASSIFICATION B DESCRIPTION J TP-E20 #4 I I I ISP-SM I GRAVELLY SAND WITH TRACE SILT ~GCATTERi.m COBBLES AND BOULDERS BORROW AREA E 'l'EST PIT TP-E20 DRAWN BY:J.M. APPROVED BY:T.1. DATE:Dec.1981 PROJECT NO,052506 '1 1 0 'j N ~~1)';1.1 };.~~~r ,!'j :l j .)'])~l 1 '"'1 ..~")1 1 1 'J -]---1 ...-~- us.S!dnddrd SIIVI Openings in Inchls U.S.Stdnddrd Sllvl Numb..s H :tdrometer >. ..Q o 10 30 90 20 -.c:.ao 'iii 40 ~ 80 50 t'"'-oou 60 -c..u..... 70 0.. 0.001'000.0050.010.015010.1515()!IO1001500 12 9 6 3 Z lin I 3/4 1/2 3/8 4 J 20 40 80 100 200 270 I I --~I I I I'--.I'e '---. I ~ '"[\ I ,, I I , ), -- 10 0 1000 20 70 90 30 100 80 Qi 50c:: LL >. .Q -~40u... II Cl.. -s;; ao CIl ~60 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT Y DENSITY LL PI CLASS SM-S CLASSIFICATION a DESCRIPTION SANDY SILT WITH TRACE CLAY BORROW AREA E TEST PIT TP-E2] DRAWN BY: APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052506 u.s.Standard Sieve OpeninQs In Inches U.S.Standard Sieve Numbers Hydrometer 00 12 9 6 :5 2 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I "Iii I i II I "I I II I I II II I I II 1"I I 1 I I'I l'I 1 1[I I I II I I I I I I II I I I I I 1 II I I I I ,.----,--i ,0 90 II I I I I I I I I I I I I I I I II I I I I I I I II I I I I I I II I I I I I I I I ++1 I , I I I 110 80 i I I I I , I I I I I I I I I I I I II I I I I I I I II I I I I I I I II I , I I I I ,+++I I , I I 120 70 II I I I I I I I I 1I I I I I I I II I I I I I I .I II I I I I I I I II I I I I I I I t-+++I I I I 130 ~=illiiH±t=-.J ~.~-1 ~~60-,----..140 ~ >-~ >. .Q .....'II I ±=j ....GI 50 ---f-----50 GI~'-"~ -~!---'I 3~40 '\.t-----j60 C. ~"~a;II>-l)~I ..... :30 Qi ---70 Q'I"'--.N 'i,I 20 +I I I I , ,, I I I I I 1---180 10 I I I I I I I ,1+++-+-+-+··+[90 ~ o LLL..L.L-I I I 1 I I II I I I I II I I I I I I I I " I I I I I I I " I 1..L...l I I I I I I L...L.-~.-J 100 1000 500 100 50 Kl 5 I 0.5 QI 0.05 0.01 0.005 QOOI BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine .I FINES Silt Sizes PILLCONTENTIDENSITYSAMPLENO. TP-E21 #2 CLASSI#I L -±==J IGP-::GH O~~E~·\Y-·E_~~LTB£I..~-'§-;JILT l .NU!1EROUS COBBLE2......EhllJ2.SCATTEMP......I I I I I I I I --1 BORROW AREA E TEST PIT TP-E21 DRAWN BY:J .M. APPROVED BY:T.I. DATE:Dec.1981 PROJECT NO.052506 ~~~'1 ill ~); - F.3 BORROW SITE H I, \ 1'1t: ~T 'I AUGER HOLE LOGS -! ) r 0.0' A.B~ Sh Sh PREPARED BY: AH-H1 Elevation 2127.5'.;.7.:-:..::1~6.:-;:;8:..::1 0.0 I ORGANIC MATERIAL WITH SOME SILT ·~~W~L...l.5 I CLAY,TRACE SILT ~;.....:...~w~..:,.....--:::-::--:....-,6.0 I SOME CLAY AND GRAVEL P~~__~"-9..L-7 ~5 ' CL-ML 24,12%,CL-ML SILT WITH SOME SAND ANu GRAVEL,TRACE CLAY Gray ___________________J3.0' 94,9%,GM-GP GRAVEL WITH SOME SAND,TRACE SILT Gray 9%,GM -GP h..~U---------------------'"3. 0 I HIGHLY WEAT'HERED ARGILLITE Dark Gray 4 ~;J>.:J....L ----::26 • 5 ' T •D. PREPARED FOR' BORROW AREA H AUGER HOLE AH -HI R&M CON SULTANTS.INC. Scale:1"=4' ._._._._._._._.25.0' 15.0':20.0'Scattered Cobbles I 55/4.0",8%,SM-SCIi ! f I I IIr56/4.0",8%,SM-SC r J [ I I Ref., SILTY SAND WITH SOME GRAVEL,TRACE CLAY Gray 12 Ref., Thermal Probe Installed to ;>. /. ••(J 'Loo'." :.~. "/Sh r-.:/ 7· /'.j;- Sh -....:.'~_:....I...~1_3,,--_9_6_,_7_%_'_~_SM_-S_C ----,40 .9 'I 'r.D.! 40.9'( Sh . _ . _ . _ . _ ._. _._ ....25.0 I Sh 0 Ref.,-72/6.0".6%,SM SILTY r;RAVELLY SAND No Visible Ice J Nb No Visible Ice,Nf SM SM '34/j.0",9%,SM 11%, 17.0'-40.9' Ref., 36,10%,SM SILTY SAND ~nTH SOME GRAVEL Brown SILTY SAND ~\lITH SOME GRAVEL Brown 4.5'-17.0' 12, 19, 16,7%,SM AH-H2 Elevation 1970.9' 7~---.:1:..:9:...-.--8,..,1 ----,-0 . 0 I ""o"V 1 ORGANIC MATERIAL 1-"""'...:,""-++,......-.....:B.....:1=.ac......:..ck 1.5 ' /",'23%SM:.,SAND WITH SOME SILT AND::~,;GRAVEL",SOME TO TRACE /..ORGM~I~MATERIAL~..",:Black to Brown~9,17%,SM :.~. /-~",",8,20%,SM •....:::~......:.,..+-I..,...."....-------------6.0' h Ii.0 ~ Q"~~<i.~ DO C~.' o:~ ,?c.o 9"'".~o·~..-,·~o· !'"'x o ·~·t·o. q....-·o<1()~.y ',.'ID'- X ,'Q •-/ ••D y"~..;;?'.;; ~ '/9 X;;;:. :0 :.? -Y':'~./. .~y~ Sh Sh 0.0' Ai' TIn Tm Sh Sh Sh Sh Sh PREPARED"BY:PREPARED FOR: BORROW AREA H AUGER HOLE AH-H2 R&M CONSULTANTS,INC. Scale:1"=4' - to 29.0' ORGANIC MATERIAL Black Surface Cobbles and Boulders 18.0' 22,9%,SM SILTY SAND WITH TRACE TO SOME GRAVEL Brown 4.5'-22.5'No Visible Ice,Nf 22.5'-29.5'No Visible Ice,Nbn Ref.,100/3",12%,CL SILT WITH so~m Sfu~D,GRAVEL AND CLAY Gray 10 Ref.,100/3",14%,CL Elevation 2079.6' ~~~~-JJ.0' Tm Sh Sh .~~ ~ Sh ~ X Sh .?:,;-< Sh ;7 .'~.' /'y... 0'X-../9 Sh 0.0' A.B':y'- -TIn Sh Sh Sh r'" 1 I~ I, ( I"" I PREPARED BY' BORROW AREA H AUGER HOLE AH-H3 Scale:1"==4' PREPARED FOR' TRACE CLAY AND, Elevation 2064.5' SM-SC SM-SC 11%, 120 Brown GRAVELLY SAND WITH SOME SILT Dark Gray 15, SILTY SAND WITH SOME GRAVEL AND TRACE CLAY 12, 18,11%,SJI1 WEATHERED BEDROCK .75,II?",SM ~.." :.0 •:0 : • ~~'12 0'~--------------------. '1:)1 "._ ".:_://:0.:;;..., 25.5'T.D.1:..l............D.....,£._ ,,"",~n-2 2.0 ' TIn Sh ORGANIC MATERIAL Dark Brown SANDY SILT WITH TRACE GRAVELSOMEORGill~IC MATERIAL ~:r--"t+."""",_B_r_o_w_n 3 . 0 ' 8,16%f GC-GM SANDy GRAVEL WITH SOME SILT, TRACE ORGANIC MATERIAL Brown-Gray I-:"'-..::..:.J~~_b_-_'_1_3_o,,_,_G_C_-_G_Jl_1 G •0 ' Sh '~ '.y, "".. .j/.; ...:~' :7·. ·iZ·..'.,? Sh Sn 0.0' A.B-.Y..-r---:-r""'l7o~--------------_O.0 ' "-"" Sh Sh Sh 16.5' W.D:.I- Thermal Probe Installed to 2S.0' PREPARED BY:PREPARED FOR: BORROW AREA H AUGER HOLE AH-H4 R&M CONSULTANTS,INC. Scale:1"-4' Ref.,100+/12.0" ._._._._._._._.25.0' REF.,Cobble SANDY SILT WITH SOME CLAY AND GRAVEl, Gray Sh 4.5'Sh Elevation 2186.2' 39,10%,SM-SC 14.0'-35.5'No Visible Ice,Nb SILTY ORGANIC MATERIAL Brown 4,23% SILT WITH TRACE SAND,GRAVEL, CLAY AND ORGANIC MATERIAL Brown REF.,Cobble 15,16%SM-SC SILTY SAND w/SOME GRAVEL AND TRACE CLAY 42,17%Sl'1-SC 14.0'-35.5'Samples Thawed Following Recovery Ref.,SO/2.0",11%GM GRAVELLY SAND WITH bONE SILT, SCATTERED COBBLES AND BOULDERS Brown ,.;....-r-.;:....,.~'---------------o.°· Sh Sh I I I 130 9%~_~M-SC 10 IShj.-..;.44"'"""-"=":::":::"""""'-'-=--=--=:....:..-------..°Sh __..LI..~:.:L_=R..:.:e:.:f:....:...!...,-=.1..:.0..:.0_+.:../...:1:.,:2:.,..:...0:.,._"~5 .5'! 12.0'I.D~35.0 T.D.. I i t ! I 9 O,Sh••.B-=- I I ,.... ( .f"" i .- PREPARED FOR' BORROW AREA H AUGER HOLE AH-H5 Scale:1"=4' ,.~\ Gray SILTY SAND WITH TRACE CLAY AND GRAVEL I.'• 15':- :.-"7 2 t,-, /11 148,10~b :$: ~. ;/33.0'~. ~ ~.l2 Ref.,50/2.0",8 gb,SM-SC ...0/.r--GRAVELLY SAND WITH SOME __~:...:.~_.::c..:..?...;.:.l--_;;;:~;;;.~;;;:~.:rT_A_N_D_T_RA_CE_'_C_L_A_Y____.;;i.(). 0 I O'c'1:>.'00~..a ~~ iQ.o13Ref.,70/5.0",8%,SM-SC o -0 O'~0°GRAVEL WI'l'H SOME SAND o~AND SILT,TRACE CLAY o 'O~})Go~D ray -.;0"':...:::.~~....;:o~___"'w .0 I T.D. Thermal Probe Installed to 43.0' ._._._._._._25.0' 10 52,11%,SC Sh Sh Sh WITH SOME AND ORGANIC MATERIAL 58,6%,SC 21 6.0'-43.0'No Visible Ice,Nb SILTY SAND WITH TRACE CLAY AND GRAVEL Gray SILTY SAND WITH SOME GRAVEL Gray 6.0'-,13.0'Samples Thawed Following Recovery 13.5'-43.0'Scattered Cobbles and Boulders._._ . _ . _ ._._ . _ . _ .-25.0 r ______________18.5' 7 11,12%,SM 7.5'-10.5'Trace Organic Material Sh ./ _0 /..;o . , :0-.'/ $: '';~ ;;i o', '/..o·.,... ~'.' Ni-H6 Elevation 2181.0' 7-12-i3_1I'?""O:--0 . 0 1 Sh 1 Sh Sh Sh Sh ..--:-L--f-+,."....,.~"""-:~:"_'""~.......,u.L.-------7.5 ' Sh _......~~--------------3.0 ' 5 3.0'-6.0'No Visible Ice Nbn ORGANIC MATERIAL WITH SOMESILT Dark Brown Sh J •...:.-:r+~~--------------6.0' Sh -..._/~, Sh 0.0' A.B. -.Y... PREPARED FOR'PREPARED BY' R&M CONSULTANTS,INC. i' BORROW AREA H AUGER HOLE Ni-H6 Scale:1"=4' - 0.0' A.B~ 'I'm 'I'm Sh Sh Sh Sh Sh Elevation 2188.4' 0.0'r-'-=4;~------------- ORGANIC MATERIAL Dark Brown 1.5'-4.5'No Visible Ice Nbn 3.0' 8 SANDY ORGANIC MATERIAL,Dark Brown _, 4.:J 9 SILT WITH SOME SAND,TRACE CLAY AND ORGANIC MATERIAL.Dark Brown 6.0' 5,14%,ML-CL SANDY SILT WITH TRACE GRAVEL AND CLAY Gray 15,17%,NL-CL 16,16%,CL SAl\lDY SILT WITH SOME CLAY AND TRACE GRAVEL Gray... •0 . ___________________l3.0' ••0·":0 ::;. 9.0'-25.7'No Visible Ice,Nb 32,13%,SC 32, SAND WITH SOME CLAY,GRAVEL,AND SILT Gray 9.0'-25.7'Samples Thawed When Recovered Sh Sh r -J I Sh 60,13%,SC 25.7'~: !~,.-Sh Ref.,100+/12 .0"I25.7'-27.5'Highly Weathered Bedrock IrGrayBrovm27.5' HEA'l'IiERED BEDROCK I i Sh I"Ref.,100+/12.0"30.7'T.D. ~Thermal Probe Installed to 30.7' Scale:1"'='4' r ! PREPARED BY: BORROW AREA H AUGER HOLE A1i-fO R&M CONSULTANTS.INC. PREPARED FOR: 8 50,6 96,GC-GM Gray 89,6%,GC-GM SILTY GRAVEL WITH SOME SAND AND TRACE CLAY 25.0' -~---~-----_._.-. Sh Sh 35.0' -.....:....=-a...-£.----'-'------''---'-------T-.D.I Thermal Probe Installed to 35.0' I I t Sh SAND WITH SOME SILT, G&'\VEL AND CLAY 3.0'-5.0'Scattered Cobbles _._._.--f?O' 26,13%,SC Elevation 2093.5' l..:i,14% 6.5'-35.0'No Visible Ice,Nbn 23,12%,SC 80,7%,GC-GM SILTY GRAVEL WITH SOME SAND fu~D TRACE CLAY Gray SILT WITH SOME CLAY AND ORGAiHC MATERIAL Brown 'yo ~o.'.X...y....i3:C'OWll_'.l3.0' .0 '"":"':~;";'::::'="-O=R-::::G-=-AN::-:-::-I:::C----:-:MA::-::T=E=R=I=A=L----:-\t-:::JI:::'I:::'H:-:S::-:O::-:ME::': SILT Black .5' Sh Sh Sh Sh Sh A A Sh 0.0' A.B~ Scale:1 n -4 ' PREPARED BY'PREPARED FOR' BORROW AREA H AUGER HOLE AH-H8 r ,... I LABORATORY TEST DATA ]) PROJECT NO.052504 R ¢M DATE October 17,1980 CLIENT:Acres American,Inc.CONSULTANTS,INC. PROJECT NAME SusHna HydrQe]ectric (Watana Dam Site)SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO.C-Ol %Unified DESCRIPTION 4"3"2 11 I~"1"3/4"11/2"3/8"#4 #10 #40 #200 .02 .005 .002 Moist.IlL PI Class. H W-Rn-")t::t:.100 95 88 84 81 78 71 64 53 38.2 24.3 13.6 8.6 10.9 21.7 9.2 GC-SCKClf.lf.lllW I (Grab Sample)GM-SM BORROW H W-80-257 100 97 92 89 84 81 73 66 54 36.0 19.6 8.9 5.2 12.3 17.1 2.5 GM-SM (Grab Sample) --_.. - REMARKSl ......_••••'.~•0••_•••.._._.•••_•••"._._ NOTE:SIEVE ANALYSIS =PERCENT PASSING PROJECT NO.052506 R¢MCLIENT:Acres American CONSULTANTS,INC. DATE October 5,1981 PROJECT NAME 8usitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO.1 (.!)LlJ ILAB~d ....I.FI NE WET DRY MOISTUREQ.o DEPTH L.L.P.I.CLASSNO.Cl::z :::!;z 3"2"11.:2'1 1"3/4"~"3/8"4 10 40 200 SPG DENSITY DENSITY CONTENT0;}jIII HI 2 1.5'-3.0'100 92 89 85 82 74 59 46 24.8 1 <C:M HI 3 3.0'-4.0'16 HI 4 4-.5'-6.0'.100 96 96 94 92 88 79 60 21 4 <?17 17 Qr HI 5 6.0'-7.5'100 93 90 86 77 66 51.7 34 21 II",(,"T. *HI 6,7.5'-10.5'100 98 94 88 85 82 74 64 55 1 ')t:;7 1')1')CL-ML *GM-GPHI8.(15.0'-21.5'100 69 57 50 45 41 34 28 20 l2 1 21 NP q *H2 2-,1.5'-6.0'100 95 91 85 69 48 22.9 1\lV 1\lP 23.17 2 h 8M *SMH25-6.0'-10.5'100 88 83 82 78 74 (;7 (;1 SO 15.0 1Q 1\TD 7,11,1 -- H2 8 15.0'-16.5'100 90 85 80 76 65 51 32.7 In 8M *H2 B,le 20.0'-25.5'100 93 84 7R 7<h?LlQ '{1 t:;17 NP q h 8M ru-*H2 330.0'-40.8'100 95 89 87 82 71 61 39.7 18 5 8,8,7 8M-8C H3 3 3.0'-4.5'53 *H3 4,~4.5'-7.5'100 94 91 86 74 59 42.0 18 5 19 14 .C:M-c:r H3 7 9.0'-10.5'100 99 97 93 82 63 40.(;1\1'1 1\TD 12 .C:M H3 8 15.0'-16.5'100 93 88 83 67 51 29.9 ILl Np q 8M H3 9 20.0'-20.3'12 H3 10 25.0'-25.2'14 REMARKS:*Samples Combined for Gradation and Atterherg Limits NV =Non-Viscous,NP =Non-Plastic NOTE:SI EVE ANALYSIS:PERCENT PASS IN G ~i I 1-1 --]~~~}_C]_])1 PROJECT NO.052506 R$MCLIENT:Acres American CONSULTANTS,INC. DATE October ]981 PROJECT NAME Susitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO.PAG E NO.2 t!)w LAB ~d -l.FI N E WET DRY MOISTUREll..0 DEPTH 3"2"1l:i"1"3/4"!.,,,3/8"4 10 40 200 L.L.P.1.CLASSNO.o:::z ::iEz 2 SPG DENSITY DENSITY CONTENT0~lD *H4 3.l 3.0'-6.0'100 82 82 73 66 61 5S 49 .17 ?O .:1 'J"":1 7 1 h 11 GM-GC *H4 5,6 6.0'-9.0'100 89 87 86 85 81 74 67 55 39 5 ?().Ii 1 <:;1 1 SM-SC *H4 ~.8 15.0'-21.5'100 92 90 R1 7P.74 64 55 41 27.2 ??1\lD 1 1 C:M H5 3 3.0'-4 '"23 H5 4 4.5'-f,0'100 95 93 89 86 78 72 62 41 0 ?1 c:.16 SM-SC tiS 5 6.0'-7.5'100 89 73 45.2 ??h 17 CM_Cr' '" H5 r;7 7.5'-10.0'100 81 76 76 7f,7f,7f,f,1 49 11 1 21 4 10 9 SM-SC H5 R 15 . 0 '-15.7'11 *H6 6 7.5'-10.5'100 97 91 91 RR 7R f,9 r:;1 1?r:;1\lU 1\lD 11"":1 1'J CM Hh 9 20.0'-21.5'6 Hf,10 25.0'-26.5'1100 9r;91 90 70 C:"":1 45.5 23 9 11 SC H6 11 30.0'-31.0'10 H6 1 ?35.0'-35.6'1no R?R?71 71 hh 47 34 19 2 21 6 8 SM-SC H6 13 40.0'-40.4'8 REMARKS:*Samples Combined for Gradation and Atterbergr.irnits NV =Non-Viscous,NP =Non-Elas±ic NOTE:SIEVE ANALYSIS =PERCENT PASSING PROJECT NO.052506 R$M DATE October 1981 CLIENT:Acres American CONSULTANTS,INC. PROJECT NAME Susitna Hydroelectric PARTY NO.PAGE NO.3SUMMARYOFLABORATORYTESTDATA III W l I ILAB~o -I.FIN E WET DRY MOISTURE NO.a::z c..o DEPTH 3"2"1 1 "1"3/4"~"3/8"4 10 40 200 L.L.P.I.CLASS~z "2 SPG DENSITY DENSITY CONTENT0«m (J) *H7 5,E 6.0'-9.0'100 98 94 92 88 82 71 51.5 17 4 14,17 ML-CL H7 7 9.0''';10.5'100 98 97 93 89 79 58.7 29 14 16 CL *H7 b,le 20.0'-25.7'100 92 88 88 87 86 84 78 71 48 27.4 33 19 13.13 SC RR 4 6.5'-8.0'NV NP 14 ~ H8 5,E 8.0'-11.0'100 97 q2 8q 82 75 (;4 4/'4 ')1::1 1 12 13 SC H8 7 15.0'-16.5'100 83 7_'L 77 72 70 (;2 5(;"iO 1(;1 21 7 7 GC-GM "--~GC-GMH88.c 20.0'-26.5'100 75 75 TL 69 68 66 60 54 45 3~21 7 6,61-- ------ BaR ow H 100 95 92 87 79 57 51 44 30.'23 6 Bul Sample .- f--I------ REMARKS:*Samples Combined for Gradation and Atterberg Ljmits NV =Non-Viscous,NP =Non-Plastic NClTE:SI EVE ANALYSIS =PERC ENT PASS IN G ,l ,11 )]1 C~Cl COl Co 1 1 c-l --~C-l '1 '1 c1 US,Standard Sieve OpenlnQ31n IflChh u,S,Standard Sieve N~",b.r s Hydrameter o 10 30 ...c 01 'j 40 ;= }; 20 90 80 ... 50 Q)III... Cou 60 ...c '"~ III 70 Q. 12 9 6 3 /1 11/2 I 3/4 1/23/8 4 10 20 40 80100 200 270 I -f-"'"1 \'\~~"'~I I I I I I "'~.j~~~-~t-~ \'""~~"'Ii!!.....................~ \~D-~~I'"~~.................r-r---r-... )\ \........"\''<..''\"""'ll;~~~'r--......'I"'-... """i'--.,,~~~~~;:...,~~~~~"'di~.......:tr--.~"""'''''''''''+f\..~"",:--i---++-t-+-t-t---+-+-----t--tti---H-+--+-+--+---j I \~~~~~~"'~!;:§;l;;;::--.....I":~~ I \"'r:::~~~~~~~~~~~~~t,,--'''''..........;.Jtttttlll---ttttt-r-r-I-r----j 1\'~~~~~~;:~~~~~ I "\I'-k ~~~~~~~fllId+-I"'I-t-r-+-+--+----+t+-t--+---+----t--+-----+-------1~\~r---"~E!S ,'~~ """~"~-....;;;;~~~ )i"-r--..:::I'-...."~~~;;::::::::t+II"'+--t--t--+-+--+--t+-++-+-+-+---+--+------i -~---.;~~~)1-++++_+_t-f---+-----+-t+-I-+-t----t-t-t------H+++---t-+--1"--~f__-_++++_+_+_+____p_..~-~~_+_t_+_+-_+____+_-_____1f++++_+_+_+___+_-~"'~--........::~~~ !-..r--.~t' )~~~ -----i 20 10 30 80 90 70 100 Q;50c u.. ~40u... '"u.. >. .0 ~ 01 Q) 3:60 0 1000 500 100 ~o 10 II o.~01 0.05 0.01 0.005 0001 100 BOULDERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes SAM P LE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION BORROW AREA H COMPOSITE GRADATION CURVE DRAWN BY' APPROVED BY: DATE: PROJECT NO. \•,~----J '-']~'-J ---,~-J -----"-1 ,----]'1 ---_.]---1 -1 c--)] US,Standard Sieve Openings in Inches U.S.Standard 5i •••Numbers H ydrom.t.r o o 20 90 30 -s= 01 i 40 ~ >.. .Q... 50 ::...aou 60 ...<: "u ~ 70 a.. 80 000,1000.0050.010.05010.55K>50tOO500 12 9 -6 3 11/2 I 3/4 1/2 3/8 4 10 r?-40 80100 200 270 ",II I I I I' "I "-~I _. I 1'-,-< ------- ~ I r-------. h.. I--.:;~ I ~h. I ~ "- I I"- ........~ )~I I'------, --_._-------. 10 0 1000 30 70 90 20 80 100 ~40 ().. Ql Q.. Q;50c lL "".Q -.c 0' Ql :<;60 BOULDERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes PI I ,---------IPLENOI...v,~,~,,~~,.m,1 I ISAM.CONTENT -~:::~,e~;'f I I I CLASSIFICATION a DESCRIPTION I ..~~--~~_~~9.2 I GC-sc-r-poorly graded 'Till'with low Plasticity I SILTY GRAVEL AND SAND WITH TRACE CLAY BOP,ROW Ar..EA H DRAWN BY'DL APPROVED BY; DATE:December 1980 PROJECT NO.05250",· U.S.Standard SI •••OpenlnQs in Inch.s U.S.Standard SI ••e Number s Hydrometer o 10 20 30 90 80 ~ 00•40 ~ >. .0.. 50 •... (; ou 160 -<:•u 70 cf QOO ,1000.0050.01O.O!!QIa.!!!!1050100500 12 9 6 3 11/2 1 3/4 1/2 3/8 4 10 20 -40 80 100 200 270 I I I'--.~I I I I I I )~, ) ~ r-... ~ ~ ~ ...... 1 ~"'- ~ 1 ~ 8. )"""" )~f~ '-- ------I---- 10 0 1000 30 -~ 00 CD ~60 70 90 20 100 80 ,., .0 -~40u.... CDa.. ...~50 i.L BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITv LL 17.1 PI 2.5 GH-SH CLASSIFICATION a DESCRIPTION Poorly graded 'Till f with Non-Plastic Fines SILTY GRAVEL AND Sp~D WITH TPACE CLAY Bop-pm.)1\;:'.£1\H DRAWN BY: APPROVED BY; DATE:Decemter 1980 PROJECT NO.0525C' ~~:1 1 J ]'1 ...)r~-·]'--1 ~---J )'--) j I ] u.s.Slandard Sieve Op4lnlnQs in Inches U.S.Slandard Sle.e Number S Hydramelu '".Q o o 30 50 20 90 ... CIl III... Cou 60 +-co 1IJ ::' III70a.. -.c CIt i 40 :it 80 0.001'000.0050.010.05010.5!l10!l0100!lOO -,I~lI'ti ~~II/~I ~/q,I/O::~/Ij q,IU O::U q,u IjU IUU O::UU UU I I r\.I I'I II I I I II "'-.Ii'--.. "'I : ..... ~ "'". '-..... ,...--, "I'lil .........."'-I ........r-.. I ............... ,....,.... )I ----0 1000 100 20 70 90 \0 80 30 '".Q -~40 <.>... 0»a.. :u 50c IL -.c: 01 'Q; ~60 BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO, AH-H1 #2 Y CONTENT I DENSITY 13 LL PI S11 CLASSIFICATION B DESCRIPTION SAi.:JD HI'rII SOr-1E GRAVEL Aim SILT APPROVED BY: BORROW AREA H AUGER HOLE AH-Hl DRAWN BY: DATE:Oct PROJECT NO. HCH 1981 052506 US.Standard Sle.e Openings in Inches u.S.Standard Sle.e Number s Hydrometer >...c o o 20 30 50 90 ... ~co'q; 40 ~ 80 ..... Gl III.....oou 60 ... C II> ~ Gl 70 a.. 12 9 6 3 2 I 1/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I I "'"I I I I I I I ..........II;}. "1:1...... ) l"-f'., ,......~ : "'-~ "..... r-...... \. I \. I r\ ")" )I\;>I ,10 -~ CI Gl ~60 30 70 20 100 90 80 >...c :p 50c iL-~40 '-'..... Gla.. 0.0101000!loo 100 !lO p !l O.!l 01 0.05 0.005 0001 100 BOu..DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION AH-Hl #4 I 17t-I--~32 17 SC SAND WITH SOME CLAY,TRACE GRAVEL AHD SIL'r BORROW AREA H AUGER HOLE AH-Hl DRAWN BY: APPROVED BY:HClL DATE:Oct .1981 PROJECT NO ~II ~~~,1 :1 1 7i 1 ~1]~:l -<-1 ~._--'1 -1 ---J 1 ~-~--l -]1 1 ·~-~l ---1 --I u.s.Standard Sieve OpenlnQ"in Inches u.S.Standard Sieve Numbers Hydrometer o 10 30 20 <: lU ~ lU 70 Cl. "- 50 ~...oou 90 -.r:. 01 'ij 40 ~ >..a 80 60 0001 1000.0050.010.05010.1515K>i501001500 " :><>",III'I "..I{£;J/O ..'v £v ..v au IVU £uu ~IV I I II I~II I I I I I '"~......r...... I "-~ ............... I r--.......N I '--.. ~ )~~ )I ) )I .--0 1000 s::. 01 III ~60 20 70 90 10 30 100 80 -~40u... III Cl. >..a ~50c: ii: BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT"I oENsTn.I LL I PI I CLASSIFICATION 8 DESCRIPTION I AH-H1 #5 ~16 I I 34 I 21 I CL ~NDY SILT WITH SOME CLAy ANDGMVEL I BORROW AREA H AUGER HOLE AH-H1 DRAWN BY: APPROVED BY:MCH DATE:Oct.1981 PROJECT NO.0525 U.S.Standard Sie.e Openings in Inches u.S.Standard Sie.e Numbers Hydrometer o o 30 ... .t= 01·c 40 ~ >-..a 20 90 80 ... 50 ::...cou 60 ...c: Ql..,.. Ql 70 n. 0001 1000.0050.010.05010.55()!50100500 '"""".:II ~,"1'+I/e:::J/D '+IU ':U '+u au IUU £uu "t:.fV fI-K I I ,I I ~ '"I I'-t-Ia :-................ I '---. ....."'- "t---I --Ie. , \ I )I , -- 10 0 1000 20 >- .Q 90 70 80 30 100 ... .&:. 01 CD ~60 ~4C'..,... Ql n. 4i 50c: li: BOll.DERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.Y CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION AH-H1 #6,7!12,12II 25 7 CL:-ML SILT WITH SOME SAND AND GRAVEL,TRACE CLAY BORROW AREA H AUGER HOLE AH-Hl DRAWN BY: APPROVED BY:MCH DATE:Oct.1981 PROJECT NO.052506 ~~1 1)~1 -0 -~~1 ~J ~]~'-l c"-1 -1 r-'l '1 ],-.-)'~-l -1 -~-)-J 1 1 us.Standard Sieve Openln~s in Inch ..U.S.Standard Sieve Number s H ydrameter o 10 90 20 30 .. .cco 'il 40 ~ >. ..Q 50 : L.oou 60 .. C 4><>"-ell70[L 80 12 9 6 3 11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I II I I I II 1\-- \I \ r\ \ \ . '\ """"- I ..... ~r---....)~r-- I--r-.-.)--I---........... 1!) --' >- ~ 30 70 IDO 10 20 90 80 -.cco G> ~60 -~40 <>.. G> [L t 50cu: 0 1000 soo 100 so Kl s O.S QI 0.05 0.0\0.005 Qoolloo BOlA..DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY .-"-\~I-{1l #8,9 LL PI GP:-:,GJ\l CLASSIFICATION a DESCRIPTION GRAVBL HITH SOhu .:Jtluu.,J,.iVII..;;;,'21 J.JJ.I BORROW AREA H AUGER HOLE AH-H1 DRAWN BY; APPROVED BY;MCli DATE;Oct.1981 PROJECT NO.052506 o 30 >. .J:J 20 10 90 '- 50 ~ oou 60 ~-c '"~ '"70 Q 80 -.c '"iii 40 ;: 0001 1000.0050.010.05QI0.55Kl!l0100!100 !n~f °.",(,+°","'""'"1"'"i'rrFr,"-r~"F-1i'TTT1-r---TTmiT3=--1 -c --F-f ,.--I ,~~J-+----jr --t -j ""!i I I '.",I -t--~f--±.--+--t----II --+-I-+-- I ~,,+!-jj--,--r-~-----~ .I i '\'H--"J h I I~,.,,----;--1-1 ' ·'I----{--+~-t--,1--.t---- I "I --~~~---+,-+1 __ I ~,I I--!---f--._-f----.t=-1 "e"__---f--+--f---__~___ 1 ~i-I +--I .~--.----r----i-- I ~~ I ~==n+I ..-"r-.t-I~, )- I I -_.- ! - i I -- I ---i J- 10 20 °'000 70 90 30 100 80 >-.n -~40 u '- '"D- -~ '"11> 3 60 '-~50 u: BOULDERS I COBBLES GRAVEL SAND FiNES Coarse Fine Medium Fine Silt Sizes -- SAMPLE NO.CLASSI F ICATION a DESCRIPTION AH-H2 #2,3,,!SAND IHTH SOI·1E SIJ:.'S_ANQ..§E!.'YEf.,-,--,,,--_ BORROW AREA H AUGER HnT ,RZ\H-B2 DRAWN BY: APPROVED BY:!1CiI DATE:Oct.19J1 PROJECT NO.052506 J ~1 ~]'I 4 j )~JJ }-]--']J --]~'-"--1 1 ---1 ---1 -]~--]~'J -1 1 U,S Slandord Sieve OpenlnQs in Inches U,S.Standard Sieve Numbers Hydrometer 20 30 ...-c 01 'Q; 40 ~ >. .0... 50 Q)r 0 0u 60 -c Q) ~ 70 Q) CL 80 90 12 9 6 3 -'--'--rr1 J ITf ---1- I I I I I I -+-+----1-----'I 100 ~"-~- 90 80 H- 70 60 ~~~GRAVEL j SAND ==f FINES~~~_ES §arse ]Finec;;meT Medium I Fine Silt Sizes ~--r:::-:-J.fI~Sizes -~.------------------_._----,-----------, SAMPLE NO.cONTENT"DENsiTY LL PI ..'CLASSIFICATION a DESCRIPTION AH-H2--"#S,.?,77,lhll 18 _~-s~l--S'~1:~~,S_ANE_~~TH s_o'ME-GRAViL I I ,--'.. ---~I ----+-----+1------------ I I I I I I .-----.-------,DRAWN BY:I APPROVED BY:Hel!, DATE:Oct.19<31 BORROW AREA H AUGER HOLE AH-H2 ,,,~..,vv'w..~.~..'v ".v.,"__.__..__,PROJECT NO 052506 , u.s.St(Jnd~11d Sie ....e Openin~!1 in lnchet u.s.Standard Sie ....e Numbers H ydl"cm8ter 100 90 ao 70 ~ 0- Ql 3::60 12 9 6 3 2 11/2 1 314 1/2 3/8 4 10 20 40 80 100 ZOO 270~·rTHlliT--T---'r-'TI~-nTT Tl +-]r r =r---Fr r m-.--~-T r-rT-,------T~r--'nrr --'--T -lOj-+----~--r--tt+fT t-\r---i--.'i-1tt-t-----i--f------l t -,~-t--.---r .frf+~10 I ~I -t-+~___I 1_t--t-_~i rlllll-J I !"II --l 1 1 ~I 120 +++_I i +......~.......In __._+- It +-t!-f-i --.----,"j'-tt--t-_I -t -1 30 .-~411 I I I _""I r-,I ~ f+t++i I I I --++++-+-+-+-~"-..........i d-u---ttt-.I 140 ~ -+ttttn I I •r'--Ni 11Im=f=-r -,---+---l ~ .-~f---~~-l--- - -50 '" -+-+-+---t---.-++.-J-.'·1 ,---!..,"I'-.."I'-...I.~-~-.-----I ---l--=l ~lit,'"l--t-~1t ....--~-r ~ +:::: :""""""'"II II ~-~I ~,-11=~t ±-----l70 ~ I-H-H-+-+--I'I I , I , , I 'I I , ,++-+i 1---t .r'-+------tllI.jao I r r r r I r r II II r r 1 I 1 m~-f---i _~..I I ~~--tl _I I E'E I'I~I.}---f Eil 1 90 .-~-f--I--I--H --'- o 1 1 1.-.-1 ---.JiIL 1.1 ..±_L--.L____T_-----.I 100 1000 500 100 50 0 5 I 0.5 01 0.05 0.01 0.005 0001 >, .0 I '---50Q) c U. ~40Cll 0... (l)a.. 30 2C 10 ~GRAVEL I SAND I FINES I r.nnr"..I '"in..r.nnr~..I Med ium I Fine Silt Sizes[BOULDERS !COBBLES 1-----I _H_,-I I I I I SAMPLE NO. ----- I AH-H2 #8 ~10 I I I S1'1 I SILTY SAdD VlITIi smm GRAVEL I I I I I +--I ------------ APPROVED BY'!1Cii DATE:Oct.1981 PROJECT NO.052506 BORRDW AREA H AUGER HOLE AH-H2 I I I I !I i --~r DRAWN BY'-l A J c-.1 ~--].-1 1 c·-1 -~l --]-c 1 -~l ._---].,-----']'--1 U.S.Standard Sieve Openings in Inches U.S.Standard Sieve Number s H ydrameter o 30 10 20 -.z::co 'iii 40 3t >. ~ 80 50 Q;'"...oou 60 -c: 'I> <)... 01 70 n. 12 9 6 !"11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 210 I I I I I II I I I II I \ '"~~I """'- I ....., ........ I ~ ~ , I I'- ~......... ............ )~ I ~ )I >. ~ 30 70-.r-oo 'I> ~60 80 100 20 90 -~40u... Q) n. ~50c: iL 10 90 0 1000 !l00 100 !lO o !l O.!l QI 0.05 0.01 0.005 QOOI'oo BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT y DENSITY LL '"PI CLASSIFICATION 8 DESCRIPTION AH-H2 #9,101 9.6 17 NP SM SILTY,GR~VELLY SAND BORROW AREA H AUGER HOLE AH-H2 DRAWN BY: APPROVED BY:MeH DATE:Oct.1981 PROJECT NO.052506 •...~-"'I'I --"".._~"'..""'-'-~__I -• US.Stondorq Sieve Openinq'in In.l1e.U.§.§jpndQrd Shive N~rnt1er.Hydro",ei., FINES Silt SizesFine CLASSIFICATION B DESCRIPTION SOL'll GRAVEL ._'L'RACE CLAY SAND i Medium .L~---.L-~U I lllWlL__J 1111lil.ll_----.J 100 -0.5 QI 0,05 0,01 0,005 0001 t-t-1tHtttil 1 80f-+++++-t--i--+----H-+++-+_t_-+---+-.~~~+++++++++I-4-I-t-1-+-1--+I---+-'HI'-+1+i j -~90 100 '-T '-r.T-.f~_s,....=$-k-a-f'1/2f.~-..i{a.~#--+1l:J ....~r '--T 1.o-1-~~-.'T''11200~~~r--I---r-----TJ'.r--t--c--;---0II.-+.---L--,--I .:-\--"--1 t-'f-f -."'!I~'--I211IT-ltj---t--~-~----I ----!1 t -1 ~ '.:l(.J .1--1---'t----+-.---t ..__·..·.-1 --..-.--1--_.------,-i-H-J.c---.-..,.--1--.....:=t '-'-l-.-J .t=.-._...__.l.-t--I---·-.-...10gIt...I ..'i "1'I ..........:...,..'!I I,...i I I I I,I I 8Oe!-J :.,,~r--...~-----l :'.llEr~=Jr -j.;-~r--I20 ,*1.___f-__.........~-.......____'__I 30 ~ '~- II I I I I I I +-----+------++.++-1-+I I I """"........40 ~ I I i'..~ ~~ -++++++-t-t---+---++I , I I I I I , I I I I I I I ......50 ~ --++++++--+--+---+---H-++++-+-+--+II +++++"""-f-g ++-+-+--+---+-I I I+++-I I ++++-1 I I I ---+---+++++-+I I'I~1-+-1-+-f--+----i+++-i-t-+-+-+----i60 ~ CI>u "-OJ I Iii I I I I I I I I I I , i I I I ,!I I I I I I I I I I I I I +--+II I I I I I I I -170 Cl. +- 70 .s;;;;I I I I I I Ol i Q> ~60 >. .t::l~50~ c:t I ;':;40 "- OJ Cl. 30 H 20 10 °'000 500 100 50 Kl 0 I COBBLES I Coarse GRAVELBOULDERSI~ -- SAMPLE NO.PI AH-H2 U1,12,1 5 I SI1-SC ~,..~------_.,."", BORROW AREA H AUGER HOLE AH-H2 DRAWN BY: APPROVED BY:~lCjj DATE:Oct .1981 PROJECT NO 05250 ]11 J ,~~')~~~-,1 "':I 1,{I j il J i 1 --"]~'l ~'"l -"-~>'~--]~-"'1 :-""-'1 1 ',.,-,,._._]---1 -',.,..)'--')]-"1 '1 U.S.Standard Sieve OpenlnQs in Inchu u.S.Standard Sieve Numbers H ydrameter o 30 10 -.c. 0> ii 40 ~ >. .0 90 20 80 "- 50 ~ L.oo l> 60 -c CI>u... OJ 70 11. 0001 1000.0050.010.05QI0.5~1050100~OO r _.--~--'~-+-1---rr'~"(t ;~~"~~I~~'v ~Iv ~Iv ~~'Iv '~v ~'v ..-~-- "",I-----~.--..---'.:=J I --t-"-----j------+-++-1-t--I--+--+--__+_---_.--.,---I----f------J !r-......EI.I I I+-+--+-+---j-----H+-++-r-+-+---+---+++-++-f''d---..f----t-----i'I I)--+----+++++-+--+-~.--j..·---++++-I-+-+-·-+--f-------jI-t+++-+-+-t------+-~+H-t--f-+_-_t_-+_-----'"~I I I ...........!_.--+--+---++-1-++-+-,.+--_-+f---_+-_-_-_-,,_ I I'-..r--... I .f---f----+-----t---+ "r--.,. --1---~f--- II++-~-+-+-t--+.-f---- II I ~ ,--'-~--~e--~_,I'·+-~f-l--'=l--11 ~c+t=t=-~ --'1----.-----t -i-I -j~-.---++-.L=f~)t ' -t-.H-~-tI-+--t-------t-0-r-{....t--f--I~._-r--+H-n~-~--t---J-l--,r--,H+-+-t-t--+--+--+---+++-+-t-+-~--I_-.--j.+++_+_+__+-+--+---'----1----+tf---..L-T---W---+-----1 I 1-±-~,1U+-01 -----Ji-H-rrr---t--~---j.'::'::-l--.L..l...:'-::-:--l---....L...----'----~_L-L..L_:':_::_--___lliL._-1--'---___JJ1U ..1 1l.L L_..L....J..-! 20 30 10 0'000 80 70 90 100 >. .0 -~ 01 CI> ~60 L. ~50 ~-~4Cu... CI> 11. lBOULDERS I COBBLES ~e GRAY~ine ~e_[Medium =r~-ine --=-3-----·---:~:~~E[===r0o~-Siz-J SAMPLE ,,'lirn-:-r LL {p,=--r:~=--------------cLAsslFlcATiONB--DEsc-RipT!ON-.---------- ._AH::.JU....JJ:-1--18 _5 ~s~E SILTY SAND WIIH SOME GBAliliL.TRACE CLAY Il------------ --t--=-j ! I I I 1-----+----1-1------------------------. APPROVED BY;MCH DATE:Oct.1981 PROJECT NO.05250 DRAWN BY: BORROW AREA H AUGER HOLE AH-H3 I I I I I .-.--------.-.,-----1 U.S.S1ondord 51 eve OponlnQo in In ones U.S Stondn,d Sieve Number 0 H Vdrometer - I --130 ~ 0- Q) ~ =bl.H,: -J IL-W.-L 20iliff-I 1m'~t . ----- T -t_-_---0 'It 1~u~~--~:]--lili~---4--~-~jaoIi!I I I I JlltlTI ~~-t--'90.._,l~'00 0.0\0.005 0.0010.050.1o.~~I)~o100~oo '<~T-.Tr~lr -f "~Uo ;:~~:~lr{mtT~nirt ..",,-Hti± I "'"+--1 i~I ~I,.."r-1-= Ill._ --~.-r-I--- ~rf-.-~,,I ~_---...----'-"--f--.---,-r----t+~-,---_.t.-t-___ -1---'--j I-i------r-,.---1--------- I i~-I tI 11 I.'~-+I ),+- I I 1-rti -.~--1-----'~1 II'..1 t-4=-I I !f-. i II I i J __~lli _.1..L 10 0 1000 100 20 ~50c 30 90 80 70 u.. +- L: 01 Ol 3:60 >-.a ~40 '-'c- Ola.. [oo~~I~OBBLES GRAVEL Coarse I Fine Medium SAND Fine ...:..FINES 1 Silt Size~ICloy Sizes __~l}-H3 #7 I 12 I I NV I.NP CLASSIFICATION B DESCRIPTION SM----4 SILTY SAND WITH TRACE GRAVEL I PILL~0fS"+-SAMPLE NO.I CONT~~I I I I I I I I I I I I I I I .._ BORROV'J AREA H AUGER HOLE AH-H3 --, DRAWN BY' APPROVED BY:MCH -I DATE:Oct.1981 PROJECT NO.0::>250 -:.1 ~~:~11J.J j 3 .....]'~-l ~·1 '-~·1 .~.]···1 ~~"'l _..)J u.s.Stonclard SI.."(lpen1n1P 11\ItIcl1 ..u.S.Standard 51..,.Nllftlber.Hydrom,t.r >. .Q...-OIl...ao U -s;o••~ -c: I) u... ~ 90 0001 100o.oo~0.010.05QI0.115(l!lO100eo<> 12 ••3 2 11/2 I 1l<41/2 3/8 4 10 20 40 80 100 200 ?:TO 0III',,"I I I [I ,'"10 )....."20'"I '"3C"..... "-....40r-. 1'0 .....I i".50 "".............) ,.,.. "~ )70 )80 ---°1000 30 2O! 10 100 70 90 80 ,.. 4 ~50c: iL:-~40......-Il. -&.o.. ~60 BOU..DERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION A&-H3 #8 I 9 14 SILTY SAND WITH SOME GRAVEL BORROW AREA Ii AUGER HOLE AH-H3 DRAWN BY: APPROVED BY:MCH DATE:Oct.1981 PROJECT NO. u.s.Standard Sieve Openings In Inches U.S.Standard Sieve Number I Hydrometer >. .Q o 10 20 30 .-.c. 00 'ii 40 ~ 80 "- 50 :: "-cou 60 ...C Gl ~ 1Il70Q. 12 9 6 3 ,11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270,II I I I'I I I II I !\ \ )"'-... \,'-. """I , r-.r-... r---.~) "'"i"""o ~I ........ ~ """'")I 100 20i 80 10 90 ~ .Q ~50c iL !«>u "- III q.30 .E 00.. ~60 10 90 °1000 &00 tOO 80 D 8 O.!!01 O.O!!0.01 0.D05 000,'00 BOLLDERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.f CONTENT I DENSITY I AH"~~#3 r 4 1 16,13 LL 23 PI 7 GC-GM CLASSIFICATION 8 DESCRIPTION SANDY GRAVEL WIT BORROW AREA.H AUGER HOI.F:1lli-H4 DRAWN BY: APPROVED BY:MCH DATE:oct.1981 PROJECT NO. <;1 ],~'r:1 .~~~,~fl ]J "1JI!J '!,~ -~~-1 --1 ----]---]----I ~-~l '--~l ---)·······1 ._..']]~'~J "---1 --~)» U.S.Standard Sieve 0l*llno.In Inch"U.S.Standard Sieve Numbsr.Hydrometer o 10 20 30 90 80 -.c 00 ii 40 ~ >. .Q...50 II)11\oou 60 -c: II)u... '"70 a.. 0001'00O.OO!!0.01O.O!!01O.!!!lKl!lO100!!OO 12 9 II 3 •11/2 I 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I 1\ It I II I II I \I Ir---.~ "\ 'I"- : I"....... ~..... ~ .......I"-.:, ........r--.... i'.... .......... I I -- )I , -.--.-0 1000 10 :30 70 90 80 20 100 .. ;40 u.....a.. >. .Q ~50 u:: ...c 00 ii~60 FINES Silt Sizes CLASSIFICATION a DESCRIPTION Fine SAND MediumBOULDE~COBBLES t Coarse GRAVEL I~ ISAMPLENO.LL PI A~Ji4 #5,6 l3OAAOW AREA H AUGER HOLE.NI-H4 DRAWN BY' A PPROVED BY'MCH DATE:Oct.1981 PROJECT NO.052506 U.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer >. .Q o O. 20 30 -L (Jl iii 40 ~ 90 80 "- 50 ::....oo (j 60 -<: CIl....... Q) 70 a. 0001 1000.0050.010.01l010.&&Kl lP !50100MlO 12 9 6 ~11/2 I ~j T I'~"","".------_.-,,,I ,I'1 I I II ,...... I "- I "-:"- I 1',,- 1""<0 ........I , ~ I I'--... ~ ......~I .................. I I'-........... Ie )I ~ ---._-..- 10 0 1000 -s; 01 'iii ~60 70 iOO 20 80 90 30 ~50c:u: >. .Q -~40....... CIl ll. BOL.LDERS COBBLES -Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I ';:;:;;.i;'~~~~1 n:'~":Tv I LL I PI I CLASSIFICATION 8 DESCRIPTION I AH-H~..#7,8 I 11 I I 22 I NP I 8M I GRAVELLY SAND WITH SOHE SILT I BORROW AREA H AUGER HOLEAH-H4 DRAWN BY: APPROVED BY:MCH DATE:Oct.1981 PROJECT NO.052::.J j "\\.1 -------1 1 ,~]1 \"--J ']__C)--1 «--1 1 -],-)--..-J us.Standard Steve Openln9s In Inelle.u.s.StandClrd Sieve Numbe..Hydrometer o 20 30 90 10 -~ (Jl••40 ~,., .0 "-50 ~III...oou 60 -c: IIu 70 ~ 80 000,1000.00110.010.0110.1OJleD~100500 12 ,6 3 2 1112 I 3/4 1/23/8 4 10 20 40 80100 200 270 fT""'o,.~I I I I [I I ......1'-.... "") ....1"- ja.......... ......................., .........."'" I"'--.....,.....r--..... '......... ..............- ) .- 10 °1000 -~. 'i ~60 100 70 80 90 20, ,., .0 ~50c: i:i: i 40 l,J =Q.30 BOll.DERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTIONPILLSAMPLENO.I CONTENT I DENSITY AHrHS #4 I 16 I I 23 I 6 I SM-SC I SILTY SAND WITH SOME GRAVEL AND TRACE CLAy I BORROW AREA H_ AUGER HOLE Ail-as DRAWN BY' APPROVED BY' DATE:Oct. PROJECT NO. US.Stondord 51 •••Openings In Inches u.S.Stondord 51 •••Number I Hydrom.t.r o 10 30 20 .....c. CIt 'i 40 ~,.., ..Q.. 50 III.... Clou 60 -~ III U.. III 70 11. 80 12 9 6 3 2 11/2 I 314 1/2 3/8 '"10 20 40 80 100 200 270 I I I'I" ......... II I I I I'I 1 ~ .........! ....... __._1 ) ......~ ~r-... ~ '\, '". )"- ) ) )i 30 70 100 20 80 90 ,.., ..Q -.c.o III ~60 -~~40.. III 11. ~50 u:: 10 90 0 1000 ~oo 100 w [)II o.~01 0.05 0.01 0.005 0001 100 BOLL DE RS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. AH-H5 #5 LL PI CLASSIFICATION a DESCRIPTION BORROW AREA H AUG:ER HCLE··Aft",115 DRAWN BY; APPROVED BY;MCH DATE:Oct.1981 PROJECT NO.05' 1 v ,1 1 '71 1 ~'\ ',I , ~l J --J -'~.1 ~---.cl ~'-h-l -----J ----1 -]---}-1 ----1 ~,---_oJ ",-'-]) U.S.Standard Sieve Open'IlQ'in Inche,U.S.Standard Sieve Num~"Hydrometer >. -'l o 10 20 30 -.c:.ao 'i 40 ~ 90 80 50 ~'"L-ao U 60 +-C <!l U ~ <!l 70 a. 0.001 1000.0050.010.0!!01O.!!!lD!lO100!loo 12 9 6 3 11/2 I 3/4 1/23/8 4 10 20 40 80100 200 270 II I I I I \ \ )b.;............ I , 'f\.. '\.--......... I r-........ ............ ......... -~ I"-....I"'-Ie )i -I! --- 10 0 1000 20 90 -~ (JI II) ~60 70 80 >. -'l 100 i q() u ~ Gl ~30 lD 50c:u:: BOll.OERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes I SAMPLE NO.I ~g~sTl~~EI oR:siTY I LL Ipi I CLASSIFICATION 8 DESCRIPTION I I Alf-H5 #6,7 I 10,9 I I 21 ~4 j SM-SC ~~!-,TY SAND WITH SOME G~L,,~~?.?~C~CLAY I BORROW AREA H AUGER HOLE AH~H5 DRAWN BY: APPROVED BY: DATE:Oct. PROJECT NO. U.S.Standard SI •••Opening.in Inches u.S.Standard Si ••e Number.Hydramet.r >. .,Q o 30 10 ...c: at 40 .~ 20 90 "- 50 =....ao U 60 -c Cllo.... Cll700.. 80 000,1000001l0.010.01lQIO.llIIK>!lO100lloo 12 9 6 3 2 11/2 I 3/4 1/23/8 4 10 20 40 80 100 200 270 I I"'-...~I I I I II ,',-- I "I ~ .......~ I'--.. ............, !'or-.. ~ ) ")~ "'"!'o~ ) )I - 10 0 1000 20 30 80 100 70 90 >. ..Q -.c: at Gl ~60 -~40o... Gl 0.. ~50 u::: BOLLDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. AH-li6 Y ::ONTENT I DENSITY 2 LL PI CLASSIFICATION a DESCRIPTION BORROW AREA H AUGER HOLL AH--H6 DRAWN BY; APPROVED BY:MCH DATE:Oct.1981 PROJECT NO.052:506 1 ~!I ~,~1 1)!J 'j ~ci j J 'j --]<---1 C}c-......•...]~--)-~l --)----1 /~')-.)~-]1 1 ----'J U.S.Standord SI.v.Openlllllllft Inch ..U.S.Standard SI.v.Numb...Hrdram.t.r o 10 20 30 90 .. ~o'i 40 ~,.. ..Q..50 IIOIl..o 8 60 ..c: III ~ 70 ~ 80 0.00,1000.00110.010.0110.10.115Deo'00500 12 9 I 3 2 11/2 I 114 1/23/8 4 10 20 40 80 100 200 270,I II I ""I'1 I I I' .... ""l"-I '" I "I'.... "lr--...... ""1'0", r-e ...... '-"""- I )I --- 10 °1000 ~o 70 tOO 80 90 ,.. ,Q •50 ~ i 40 CJ; ~30 ..r.o.. ~EO COBBLES GRAVEL SAND FINESBOLl.DERS Coarse Fine Medium Fine Silt Sizes SAMPLE NO.CLASSIFICATION a DESCRIPTION AH-}I6 #10 SILTY SAND WITH T~CE .QMYEL .AND "'c. BORROW AREA H AUGER 'HOLE API..:.R6 DRAWN BY: APPROVED BY:McH DATE:Oct.1981 PROJECT NO,052506 U.S.Standard Sieve Openings In Inch..U.S.Standard Sieve Numbe..H ydrameter o 30 10 20 90 -s::. 00 iii 40 ~ >-.Q 80 "-50 4l~g ou 160 -c 4l ~ '"70 0.. 000,100o.QOtI0,010,0150.10,155IJ~1001100 Ii!1II Ci il .:I la I ill'"II':ill"'"IV .:V "'v au I\JV .:vu ~(V I I ,I II I II I I \ 1\ \-"-I "....... ......Il - "' \ I ""........... r-.................. ..........~ "-... )I - 10 °1000 20 70 90 >-.Q 80 i 50c:: 100 u:-;40 u ~ Q.~ -s::. 01.. ~60 BOU.DERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT I DENSITY )ill:-jJ 6 #12 LL PI 6 VELLY SAi'lD CLASSIFICATION 8 DESCRIPTION BORROW AREA H A6GER HOLE AH~H6 DRAWN BY: APPROVED BY: DATE:ilr't PROJECT NO. 1 'il l ~~~1 ),~),11 'I,, jJ ,-.:.3 :1 _,1 J .'j "it , ~~C~],'~C]~~~~l ~'l ~~-~~}~c-l }~~1 '~l ~1 )--]-1 --'-l -'-1 U,S,Standard Sle.e Opentllll'In Inch..U.S.Standard Sle.e Humbert Hydrometer o 30 10 -.i:: 01 40 ~ >...a 20 80 .. 50 QlVI....oou 60 ... C QI ~ al700.. .~-.-....,...._..,--,-..--.._........_..... I I'T ~I I I II ""- ~...... )~ ............... .....1'..... r"--I'o... """-""'-~ •• I )I20 80 70 100 90 ... &:. 01 'ii ~60 ... ~40o.. II n.30 ,.. ..a ~50 u:: 10 90 °'000 &00 100 !lO D &O,!!QI O,O!!0,01 O.OO!S 0.00,100 I COBBLES GRAVEL SAND FINESBOl.LDERS Coarse Fine Medium Fine Silt Sizes SAMPLE NO.CLASSIFICATION a DESCRIPTION ,AH-lf7 #5,6 SAHDY SILT "''lITH TRACE GRAVEL AHD CLAY BORROW AREAH AUGER HOLE AH-H? DRAWN BY: APPROVED BY:HCIr DATE:Oct.19<31 PROJECT NO.052506 U.s.St andard Sieve OpenlnQs in In chn u.S.Standard Sieve Numbers Hydrometer o 20 10 30 50 ~... '-CIou 60 -c OJu '-., 70 a. ...c-o ii 40 it ~ 80 .~~w W ..1'1'".w ~II L.oJ,U ~'w ~w ~w .......I..,...,50...,...,01;",", I ,I I'............I I I I '"~ I --.................. )r-..........r-...., I'-... .......... " , )I20 80 100 70 90 -.co.. ~60,... .Q -~q() u ~... Q.30 ;50 <:u: 10 90 0 1000 ~oo 100 ~II ~O.~01 0.05 0.01 0.005 0001 100 BOLLDERS COBBLES GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTION .__...-._..,,-,n'7lt."'M PILLSAMPLENO.I CONTENT I DENSITY I I I I ~C'1\.'t..TT"'\~Z l.'T"rrn r"'1"rrT1:n nr-..lI..".......-I____~!:!:_H7 #7 I 16 29 14 CL _~~}t?.'::f.2~~::ti~~-'-±~L..""~J.·HiI ~,""W,l,N-j,l..dOJ I,;'NHL.LJ EORRQW AREA H AUGER HOLE AH-H7 DRAWN BY: APPROVED BY;MCU DATE:Oct.1981 PROJECT NO.052506 l 'J ~1j ]1 ~1 "~ )j ],--],.-1 '-'=J ~J "..........•)'-~l .ee]"1 ']"--1 "-'1 '__C),._]r]ec-----l ') U,S,StClfldo,d SIIYI Opentnoe In Inclli'U.S.Standotd Slavl Numbert Hyd,o,,"tlr o 30 10 20 -~ ~ '. 40 ~ ""~ 80 "-50 IIWI L-oo I U 160 -c II ~ 70 ~ 12 9 8 .J 2 11/2 I :!lf4 1/2 3/8 4 10 20 40 80100 200 Z70 I I ro-.. I I'I II I I I II f'e ~""""'-...~ )~ r---....... "'-"-. i' I'. r'- ........I ""i'... '",,~ )I 90 201 80 70 100 ~40o ~• ll.30 "",g ~50 iJ: -6:- ~.. ~6O 10 90 0 1000 'O<l 100 !lO l)!l O.!!QI O.O!!O.QI o ,OO!!Qoo,'OO BOLL DE RS COBBLES GRAVEL SAND FINES Coorse Fine Medium Fine Silt Sizes SAMPLE NO.CLASSIFICATION a DESCRIPTION AH"":Iil #9,10 S!illD W,ITH SOMEC~'¥r GRJ?VEL.f .AND SILT .BORROW AREA H .ADGER HOLE 1-ur'-"n 7 DRAWN BY: APPROVED BY:MCli DATE:oct.1981 PROJECT NO,052506 U.S.Standard Sieve Openings ir,Inelles U.S.Standard Sieve Numbers Hydrometer o 20 10 30 90 ~ CIl i 40 3: >. .£l 50 ~III '-oo<.> 60 ...<: III ~..70 Q. 80 0001'0000050.01O.OIl010.11IIc!lO1001100 .~~¥~..."..~p .,......./...~.¥--TV --.......-_...._..... I ..,.",....I II I I I I "'- ..... I ............ ......"'"I -.......... ~.......... I ~~ "- I r--....... ""lit )I - 10 °1000 20 70 90 80 >. .£l 100 ... .&:. CIl 'i 3:60 ~50c iA:... ~«>o.. "ll.30 BOLLDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION AH-H8 #5,6 12.13 25 11 SC SlillD Wl,'rH SGMESILT,GRAVEL,AND-OUY 80RRGW ARE:A H AUGER HOIlE"Al1-H8 DRAWN BY: APPROVED BY: DATE:Oct. PROJECT NO. MCR 1981 2506 ~'l."l ,,OJ ~'I ~~il .~1\~J.'.J --1 '-··~l 1 .--]·'··-1 e c __--)....].]--·-1 1 ._-----)------1 --~--··l -1 --] u.s.Standard SI.~.Openings In InelllS u.s.Standard SI.~.Numbers Hydram.t.r 90 20 10 o .30 -.c ~.ij 40 ;t,.. .Q...50 II'"~ 60 -c Cll ~ 70 If 80 0.00,1000.0050.010.05QIo.eeK)eo100!loo 12 9 6 3 ~11/2 I 3/4 1/23/8 4 10 20 40 80100 200 210,I II I I I f r I - ... !\! \ ,,I,r-...l :--...r-.... I '".... I'~ I ~.... ~I--~-"-.......... "-+- 1 I ~'8 I I ) ) I ,I.. 10 0 1000 ,.. .Q "-~50 u: 30 20 ~ ~ 'i ~60 80 90 70 100 -;40 u "-II Q. OOlLOERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY AH-H8#7 LL PI Gc;~GM CLASSIFICATION 8 DESCRIPTION BORROW AREA H AUGER HOLE AH-H8 DRAWN BY' APPROVED BY;MCH DATE;oct.1981 PROJECT NO.052506 0 10 20 30 ... .I:: CI' i 40 ~ >. .<> .... 50 II I/).... 0 0u 60 ....c II> ~ 70 IIIn. 80 Ie Hydrometer 30,1111 I I I I I 11II I ,I'I III', I I I I 1II1 I I I I I 'II I 1 1 I I 1I11 I I I +-I I U·S.Standard Sieve QpenlnVe in In~he.U.I!1.S!gndqrd ai,ve Number. •1.2 20 40 1.10 100 200 270 100 '-I'r .r f rill r TiT="1I--"1"¥T~r('---r-\-r"[ITI';-I-rrT'"-r-I-'--1---'1---'1'-1-'1-'1'-r'1-'1--"1-"-1---, 201111 I I I I I I'll I I !I 1II1 I I I I I I'll I 'i I +-,III I!,'I I III I I I I t I I 70 I II""I I 111111 I I I I /;lOll II I I ~4·c .'._H··I-H4-1 1·i-II -·11 HHI 1 I I'III I I I I I I III I I I I I I I \X)II I I I I ,I··I .-H.._.-..,I HI -I I I II I I 0 j I I I I I I I I I I j I I \ I I I I I I -~40 +-+-+-11111+I I I Iu ~..n. -.c ·~••~.m~60 •I I I I I I Ii50 1 .I ••.I I I I I I I II I I I I I I I ---I ~tffifEEB tffifEEB ffiHHfJ l1ffi1f8 fffiffH1 mrn3±-{oo 0 1000 SOO \OO!lO Il S I O.S QI 0.05 0.01 0.005 QOOI BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTION---------.----.--.I PISAMPLENO.I cONTENT'"I DENsiTY I LL I Ail-lIB #8,9 I 6,6 I I 21 I 7 I GC-GM ~_§J~~~±>__w..ITilc SQ~SAND~~L~MIL.r.EAcr_CLAY I BORROW AREA H AUGER HOLE AH:-H8 DRAWN BY: APPROVED BY:MCH DATE:Oct.1981 PROJECT NO.052506 ~~11 l 1 "~)\\.1 ~\i .5 :",y Project No.052504 Dote 11-20-80 RBM Consultant Inc. LABORATORY COMPACTION CONTROL REPORT,- ", Job Name and Location Susitna (Watana Darn Site) Architect or Engineer Acres American Inc. Contractor-I I A.Description of Sci I:Poorly Graded "Till',I SILTY GRAVEL AND SAND W/TBACE CLAYI. C Unified AASHO Material Mark Classification GC-SC Classification __......, i Source of Material Borrow Area H Sample No.W-80-256 "...Natural Water Content 10.9 %Natural Dry Density PCF Specific Gravity Liquid Limit 21.7 %Plastic Limit %Plasticity Index 9.2 ~B.Test Procedure Used T-180 Method liD"-AASHTO C.Test Results:Maximum Dry Density 139.0 PCF OptimLJm Water Content 6.2 % \ Sieve Analysis \ """I\. :Size %Passing \ \ 2 "100 \ 1 ,!:i"95 1\1 "88 \ 3/4"84 140 \-1/2"81 ...I I""1\:3/8"78 r "-\ #4 71 I '\\~ #10 64 .....I '\.\'a0 #40 53 0 ..,j LL.\.\\. #200 38.2 u I "\ .02mm 24.3 lD 135 I I I\.\~F =>I \.,.Y-.005 13.6 u a::I '"\1\';l.002 8.6 w '\.\a..I \\u)...!I ,r-w -I T \i I I-.---l \ >-:\....., I·I'!"",iii I '-.z 130!w \Cl >-\1 a::\Cl 1,.... i I 1\ l 1 \ \, I""" \ 5 10 15 r-" I WATER CONTENT -PERCENT OF DRY WEIGHT p>- I F.4 BORROW SITES I AND J - I""'" I ~, -~- TEST PIT/TEST TRENCH LOGS !IPDW]t--AL_A_SK_A_P_OW_E_R_A_U_TH_O_RI_TY-------IHomoSUSITNAHYDROELECTRICPROJECT RIVER ALLUVIUM TEST PITS LOCATION PLAN DRW ~&M CONSULTANTS,INC.I-'C,,-,-H'-'CK':--i__-i ......'''''••••••Ot.-Og ••..,.~\."NN••••v.v ....o....APplO 5.0'T.D. ,.,... r- i r TP-Rl r-9_-_1_7-_8_1_..,......--.--.~O•0 ' G 0.0 "O.o.·O·~·leD 0.00.0.0 GRAVEL WITH SOME SAND '0:0'0.'0 0 AND SCATTERED COBBLESOi?i?()\J.D0 Brown G 0.q °0'.·0......-'-0'GP'0'0'0 0 ~·O~0 (;if·r- G '·O··Op.O G) \)..(jDfo ._,G "Do·oOo·.·f-(§)GP 3.5~·o.·?····o-=-.'O'0.0.'Dr---00'.0't;::>.. G O.·C?~()@GP \-:..-=..0.:....;.0:.....:....•.....:._..+-.----'4.5 'T . D. TP-R2 r"'9~-:=:1-:-7-.....:8:::;:1=..,-..-r-....,....-O.0 I G {)Q"0 69:0 '/1 fi\GP.·.?:o·V 'CJO'-O~O.oOo'O':O°O~n 0 o.00vo.·Qv:O·()Q'o o·9.;:b.o..,f:;?c:?0 .O·:O.t::?:?o·:Q·.GRAVEL WITH SOME SAND ANDo'O'P O·D'0 SCATTERED COBBLES <:1..:c:?:0"BrownQ:qt:?'S~6 .,O:~J°.o:o~ '.'-',.0 '."o:·O·b V[)t;?o·a··OQc?ciQ.fQ 5.0~PYSOI 0GP AU.&~RESOURCES LIBRARY u.s.~t a1 the hterl~ ,! R&M CONSULTANTS.INC. ·RIVER ALLUVIUM TEST PITS TP-R1,R2 Prepared for: Scale:1"=2' 5.5'T.D. ~ i·'I I 1 R&M CONSULTANTS,INC. Brown RIVER ALLUVIUH TEST PITS TP-R3,R4 4.5'T.D. Prepared for: Scale:1 "=2 I - Brown r [ r TP-R5 9_-:-:l-;:8::-:--=8=-1~"'i'\":<.::::1r-0.0 ' I·Q:··.O··O ·""0:0"0'.......C).C?,:i; G ··:~'b:6?"::~[·CD GW."0'0"·0,p.,'..·.o.O·~~·q:.SANDY GRAVEL D.9O:%.6·'-0{T. 2 0 _·O·o..i?ro:pQ·.:O:. •:....I.-_:...9.~Q:C)'·O.-=-../7..v "c::J:O'.oYO'O .'.'-'~<I--:-0'. :OOJ?~:-:'O'."PO:·.&O:__ ____3 O' G p·I:t:.Sj ..O·.:··..o::·L@GW----· O '·O:'·..··.()<:).:..SAHDY GRAVEL WITH SCATTERED.;r---,D ....D.e---.,:O"r~~q.b4:~~:~~S ·oL.,.j ~~~~........._...;..;.,-,,0;..,..:;:::••=.0;:.:.:"""'--'l--4.5'T.D. ______2.0' @ML-SM SILTY SAND I>lITH TRACE ORGANICS Black to Brown ORGANIC SANDY SILT WITH TRACE CLAY Black to Brown CD f:gI~~;;c.+--1 -------- 1£-'-c:..L.......;..L..;.-:.<....;..::""'-I 5.0 IT.D. H"7;r.7":T::""T"':"'7'Ir-----------------O . 0 ' -=- G r Prepared far: RIVER ALLWIUM TEST PITS TP-R5,R6 R&M CONSULTANTS.INC. Scale:1"=2' R&M CONSULTAN'rs.INC. SANDY GRAVEL Brown 3.5' Q)sp SAND WITH SOME GRAVELBrown"--4.0 'T.D. (DGW GRAVEL WITH SOME·SAND AND SCATTERED COBBLES Brown and Gray Pr ared for: RIVER ALLUVIUM TEST PITS TP-R7,R8 Scale:1"=2 - .,J - 1 -I ,. - "... ,... ,..... ! G G G TP-R9 ,.,.9..".-,...,....,1..,:..8"7-....,.8....,.1.."..,.,,.......'7r""O. 0 ' Q)SM Brown and Gray 1.5'Scattered Cobbles SAND WITH SOME SILT AND TRACE ORGANICS 3.3'Boulder 3 5'k:::===~~:::::~L~:"":"':=__~~:::::::":"__________.T •D. Water Table Not Encountered. TP-R10 r.'9""'!"~7l....,.8...",."-....,.8~1<."':"."....,,,....----------,--------o.a' SILTY SAND Gray __3.5' SAND WITH SOME SILT Brown ~~~~::..:..;-7~-=--:--=---_:_----=------------5.5 'T.D.Encountered - R&M CONSULTANTS,INC. Prepared for: RIVER ALLUVIUM TEST PITS TP-R9,R10 Scale:1"=2' - ~I ' ____3.S' SANDY GRAVEL w=::.=...:..=.:..="",---{@ g~VEL WITH SOME SAND Brown Boulders at 4.0' ~~~~:'r-""'i ------------ ~~:,i;;:,..,.,..,..,....,.,.."C':T""----------------0.0' G !""'Ii 0.0'~~~r---------- SANDY GRAVEL Brown 1:11&th1&2:L~0~G::.:::w:.-5.0 'T.D. Water Table Not Encountered. R&M CONSULTANTS.INC. hepared for: RIVER ALLUVIUM TEST PITS TP-Rll,R12 Scale:1"=2 i~ - G G 0.0',.?;.:;.;~~....".,.....,.::r-------------- SANDY GRAVEL Brown J:J.{f.;~~.cl:L..---L.:::::.....-6.0 'T.D. r - ,..., i I R&M CONSULTANTS,INC. RIVER ALLUVIUM TEST PITS TP-R13,R14 Sacle: Prepared for: 1"=2'• G G G G TP-RIS 1"'9_-...;;;2;...;;0'---...;:8:.,:1=------:--,0.0 I ORGANICS Dark Brown -----------1.0' SILTY SAND WITH TRACE ORGANICS Brown Cobbles""'""'"-"-'-"""-'--'-"-c....:.;-'1-......L 6.0 'T.D. Water Table Not Encountered rf:;7?:'¥-.-7~~~._.::':r---------------------0 .a I SILTY SAl~D WITH TRACE ORGANICS Gray --3.0' SANDY GRAVEL WITH TRACE SILT Brown ~a;..;=<>===:::::L 5.5 'T.D. Water Table Not Encountered - 'IIl!lm: I - 1"=2'.~&M CONSULTANTS,INC. RIVER ALLUVIUM TEST PITS TP-RlS,R16 Scale: Prepared for: - AND -I TP-R17 9-20-81 ~D''':::?,(,o.:b>O:·l?:/'i.'.v,·Y7;obCrV:?..;d..w ··,":.,.,.'.... l'r:??2aQ .a 'c::rY1ta~A~~~~:d"'"Q~Lf. G Ili2··;Q;k;.l!.O:CD GW~bq9pao~'GRAVEL WITH SOME SANDP)7?xi020.·S9iv.SCATTERED COBBLES'0'"d.~.b.9fj.Orr~Q.~.,%9'~o~q·o.o:·D:.·:0..··~g~~g 4.0 ' -0~:r;;5.:Q~Qo~:...-..-..--------4.0' G fiYJJ..::9.~p.\0 ~1NgV GRAVEL WITH TRACE SILT Brown '--4.5'T.D. TP-R18 SANDY GRAVEL Brown Not Encountered ~~~::c..,.::.L...-......L,...;=__5.0 'T.D. Water "8~~""""""==:r----------------0.0I G R&M CONSULTANTS,INC. RIVER ALLUVIUM TEST PITS TP,...R17,R18 Scale: Prepared for: 4.0'T.D. TP-R19 .-9,....-:-:-2,...,1,...,-,.,..8..,..1'"':"'7........:':"T'",0.0 I G ~Pcj:a~~·:;,·/j±CD ?t6.<·:«t)h.SAND WITH SOME GRAVEL,TRACE ~]~~:~~ICS AND SCATTERED COBBLES _____3.0' }%?:~~.<'.)~;;r ~;~~WITH SOME GRAVEL G :;::.....: :.:.:::.P>I 0 S W-s P Densly Packed Cobbles and Boulders at 4.0' Water Table Not Encountered """'I 1, ~I G GRAVEL AND ORGANICS' Brown ___1.0' SANDY GRAVEL tUTH TRACE ,SILT AND SCATTERED COBBLES Brown 11:'..+.........:=:0::=..;:.........-"''-=5.0 'T.D. Water Table Not Encountered, .., i - Scale:1"=2' R&M CONSULTANTS.INC. RIVER ALLUVIUM TEST PITS TP-R19,R20 :Prepared for: -- r - !"'" \ I""" I G G B~~b=:I:""T'"----------------_O.O I SA1\lD AND GRAVEL WITH NUHEROUS COBBLES Brown u.ol.LAll~~.:..:L----L..-=-4.5 'T.D. Water Table Not Encountered. 0.0'r;==::~~~~------------'-- SANDY GRAVEL WITH SOME SILT AND SCATTERED COBBLES Brown 4.5' @GW =~~""'::'::;..:.L....-\.GRAVEL ~VITH SOME SAND AND SCATTERED COBBLES Brown Water Table Not Encountered. R&M CONSULTANTS,INC. Prepared for: RIVER ALLWIUM TEST P+TS TP-R2l,R22 Scale: ,... I r i -i -I LABORATORY TEST DATA ~)<----']'_.""-"1 "'-~1 fj ~J ····-'1 '1 '1 -]·--1 "~"'-1 PROJECT NO.052504 R ¢MCLIENT: DATE October 17,1980 Acres American,Inc.CON S U L TAN T S I INC. PROJECT NAME Susitna Hydroelectric (Watana Dam Site)SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO. %~nified DESCRIPTION 4"3"2"1~"I H 3/4"/1/2\'3/8"#4 #10 #40 #200 .02 .005 .OOL Moist.LL PI Class. STREAM ALLUVIUM W-80-302 100 92 90 82 69 58 45 38 27 23 14 2.6 GP (Crab Sample) - tEMARKSl NOTE:SIEVE ANALYSIS =PERCENT PASSING PROJECT NO.052506 R¢M DATE October 29,1981 CLIENT:Acres American,Inc.CONSULTANTS,INC. PROJECT NAME Susitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO.PAG E NO 1 of 3 (!)w ~d O:dgsz~z uc.rln OJ (fJ 4~"4"3"2"1~"1"3/4 '1/2"3/8'#4 #10 #20 #40 #80 ~100~200 .02 .005 .002 CLASS TP-R1 2 1.5'2.0'11 nn q<;Rq 78 f..7 <;q 4q 41 11 ??1 f';1 ':l c:.II ...,')GP TP-R 4 3.0'-3.5'100 99 87 79 65 56 45 39 28 .20 14 13 5 4 1.5 GP 'i'P-Rl 5 3.5'-4.5'100 98 94 79 67 57 46 39 29 21 17 13 4 1.5 GP TP-R'1 0.0'-1.0'100 77 64 54 44 39 33 29 23 18 16 15 7 5 2.0 GP TP-R 2 4.5'-5.0'100 94 89 74 63 50 42 14 30 7.1 14 11 1 1 h c;')n GP ';:l TP-R._2_4.5'-5.0'l",QQ"~8q ~f..n 47 40 ?g ??c'17 lLt 5...-<1 ')GP TP-RL 2 4.0'-4.5'10n q7 8f';77 f..<;<;R LtQ 41 11 ?<;17 1 1 ')0.7 GP.- TP-R~1 0.5'-1.0'100 90 79 69 61 53 47 36 23 12 8 5 4 2.2 GW TP-R 2 3.0'-3.5'100 95 90 80 75 66 60 51 44 32 21 10 8 2 1.1 GW TP-RE 2 2.0'-3.0'100 99 95 92 89 72 65 k17.2 15.6 3.8 2.4 ML-SM-- TP-R"1 0.5'-1.0'100 95 86 71 62 52 45 32 24 18 11 7 1 O•.:GW TP-R 2 3.5'-4.0'100 91 91 87 86 84 77 75 72 47 3 1.e SF TP-Rl 1 0.5'-1.0'100 92 73 67 57 51 44 39 28 19 15 11 5 4 1.7 GW REMARKS:River Alluvium Test Pits,Watana Area NOTE:SI EVE ANALYSIS =PERCENT PASS I NG C "JI _.J L ••J t J J .J J J J 1 -1 :-l----}1 ----,J --]1 ]-1 --} PROJECT NO.052506 R¢M CLIENT:ACRES AMERICAN,INC.CONSULTANTS,INC. DATE October 29,1981 PROJECT NAMESusitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE NO ;(of 3 (9 w ~d tid DEPTH13z~z 4~"4"3"2"1~"1"3/4 '1/2"3/8 '#4 #10 #20 #40 1#80 I#lor 1It20r o?on".op?CT·ASS[lJ U)- TP-R9 1 0.5'~1.0'.lOO.9q 6.~~----5.Q 2A~f 4n 1 I;1.3 'SM !rP-R11 1 1.0'-1.5'100 99 82 ~.11n (SM b:'P-R1 D 2 3.5'-4.0'floo 92 88 81 76 71 68 64 61 59 r:;r:;38 ":\1 114 2.0 .67 .63 SM-SP- --- [rP-R1 1 0.5'-1.0'100 90 80 66 58 48 42 33 27 24 19 7 ~2.4 GW 'I ': GP[rP-Rl 2 3.5'-4.0'100 ~81 68 60 49 42 30 ...2.2..-:-°1 Cl 14 5 4 2.0 --_.-- !I'P-Rl 1 0.5'-1.0'100 92 77 65 58 49 43 33 26 23 21 7 3.3 ~P -- TP-Rl 2 4.5'-5.0'100 ~79 f,7 -.5...9.-4Cl 41 ":\??I;?o lLl 5 3 1.5 GW TP-R1 2 5.5'-6.0'100 93 85 74 65 54 49 38 31 22 12 4 3 1.7 GP -- TP-Rl 1 0.5'-1.0'100 95 88 75 66 55 48 36 28 22 ?o 7 ".L2 roT.7 TP-Rl 2 5.5'-6.0'100 93 84 69 61 52 47 36 27 19 13 S 4 11 .4 GP--- TP-R1 2 5.5'-6.0'100 Cll 82 44.4.8 1.1 0.7 3M -- TP-Rl )1 0.5'-1.0'100 89 78 .36._SM TP-Rl ) 2 4.5'-5.0'100 93 85 72 64 56 51 41 31 24 20 13 11 6.0 1.2 0.59 0.44 GW-GM REMARKS:River Alluvium Test Pits,Watana Area NOTE:SIEVE ANALYSIS:PERCENT PASSING PROJECT NO.052506 R$MCLIENT:Acres American,Inc.CONSULTANTS.INC. DATE October 29,1981 . PROJECT NAME Susitna Hydroelectric SUMMARY OF LABORATORY TEST DATA PARTY NO.PAGE N0 3 of 3 (,9 w ,~.....~d etd DEPTHgjz~z 4~"4"3"2"1~"1"3/4'1/2"3/8'#4 #10 #20 1#40 #80 ~10()~200 .02 .005 .002 f:LASS(l)(f) = TP-Rl 1 1.0'-1-5'100 98 84 70 58 hn Ll'36 ';;.]),1 16-.1 1 Ll.3.1.6 my.oiY •.J.. TP-Rl 2 4.0'-4.5"100 91 82 70 63 55 50 41 34 28 21 1 ..,11 7.0 GP-GM..LJ---- TP-Rl ~2 4.5'-5.0'100 91 84 81 73 63 56 42 33 24 14 5 4 2.8 GP _.. TP-Rl 9 2 3.5'-4.0'00 96 92 88 85 82 76 67 46 19 5 3 2.5 Sw-sp---., ~~.-------- TP-R2 J 1 0.5'-1.0'100 98 98 97 97 97 91 48 39 15.SM-SP.__. TP-R2 ) 2 4.5'-5.0'100 93 89 81 72 63 53 48 38 32 25 17 9 7 3.6 GW ----- TP-R2 2 1 1.0'-1.5'100 96 84 76 67 61 55 52 46 41 38 36 26 23 12.2.4 l.0 0.6 GP-GM TP-R2b 2 4.5'-5.0'1,00 96 83 72 56 47 36 29 18 12 9 7 .1 ?1 ?GW....- -- --.-- -- I REMARKS:River Alluvium Test Pits,Watana Area NOTE:SI EVE ANALYSIS =PERCENT PASS I N ]..1 »,J ......1 ,.J .J ...J ....J .~.._.cC_j J .J ---1 -----I --1 --1 ---]]--:)----]-~]----1 )--J "l ~---J 1 -} ~tS Stcm~.Jrd Sieve Openino-s in t-nches U.S.Standard Sieve Number.Hydrometer o 10 30 20 +-.c CJI C 40 ~ >. -" 90 50 ~ L-aou 60 +-c CL>o... CL> 70 c.. 80 0001'000.0050.010.05 200 270 01 80 10040 0.5 20104 510ro 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 ~oo 20 10 30 80 0'000 70 90 100 +- ~ CI Q,J =!=60 >. -" ~40u... Qla.. ~ ~50 u:: BOULDERS I COBBLE S GRAVEL Coarse I Fine Medium SAND Fine FINES Silt Sizes I SAMPLE NO_~;'iTENTl_DENSYTY -J LL I PI I I CLASSIFICATION a DESCRIPTION I RIVER ALLUVIUM COMPOSITE GRADATION CURVE DRAWN BY:J.M APPROVED BY:L.J .A. DATE:1-82 PROJECT NO.U~25Ub ]--.-J .--1 ----J ·-1 -~1 )..-1 u.s.Standard Sieve Openings in Inches U.S.Standard Sieve Number s Hydrometer o o 30 90 -~ 01•40 ~ >. "Q 20 80 .. 50 :: 15ou 60 -c lDu.. lD70n. 000,1000.0050.010.05 200 270 01 80 10040 0.5 20104 5()50 3 2 11/2 I 3/4 1/23/8 100 12 9 6 500 ....•-.--....._-,.I 1\I'I'I I ,I'II I I I I I \ I ~ \ 1\ \ \ ~ I \ \-1---\I --I I f'\- "-"-- '------<r-------.I IE r-- '--......r--.. -------- 11 0 ----0 1000 90 80 70-~ 01 Q) ~60 30 20 100 10 -~40 u ~ Q)a.. ~50c u. >..a BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes CLASSIFICATION a DESCRIPTION I SM~DY GRAVEL W/TRACE SILTGP PILLSAMPLENO.~~NSITY I I I W-80-302 Grab Samule Poorly Graded STREN1 ALuvrill1 DRAWN BY:DL APPROVED BY; DATE:December 1980 PROJECT NO.OSLo ..... u.s.Standard Si ••e Opening.in Inch..U.S.Standard SI ••e Number.Hydrometer o 10 30 20 90 -.r; '" 40 ~ >-.Q "- 50 ::.....oot.> 60 -c CIlo... CIl 70 0.. 80 QOOIIOO0.0050.010.05 200 270 QI 80 10040 0.5 20104 5kJ50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 .---.---.~~ I "II I I I I., I ~ I \ ~ I \ ~ I \, :\. ':\.I ~ ) "i I '\ ........ )~I ............. -I-~r-....I'~ ~Ii> 0'000 90 100 70 80 20 10 -.r; '"'q; ~60 30 .....~50 LL. ~40o..... CIl 0.. "".Q BOu...DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-Rl #2 GP GRAVEL WITH SOME SAND AND SCATTERED COBBLES RIVER ALUFTTUM TEST PIT Tp:"Rl DRAWN BY'P.T. APPROVED BY: DATE:11-6-81 PROJECT NO J J ....J .J 4"•....•).....J )...J ]J .J )~....J -)cc=}~--Cl ..-)~c~.]'~l )"-1 .)-},c.]]'--~---J --)1 u.s.Standard Sieve OpenlnQI in Inches u,S.Standard Sieve Numbe"H ydrameter o o 20 30 90 80 -.c.,. 'iii 40 ~ >. .Q "- 50 :... CIou 60 -C 4><.>... 4>70 Q.. QOOIIOO0.0050.010.05 200 270 QI 80 10040 O.!l 20104 510!l0 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 1T1l I I l+-I ~1,I 1 l''I'll I I ..I 1\IT'II~T n-'.-----..I "I '11 I I I 1 I I1\'III I I I I I \' \ \-\-: I~J~~~RI1\~i~EJ~lift~~Mi~*~mi~1~\ l' ,I --1 )'"'··1 '-.... u I ~- Jill I I I ~~-II I I 1 1 I I'"'I III I I I "i -IIIIII ~I IIrt1'1 I I I I I I -I,lilllill I ~ 20 10 30 0 1000 80 90 70 100 -J;;; 01 '0; ~60 -~40 <.>... 4> Q.. >. .0 d;50c iL BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes I----MU':>I ut<t.'p'~y ISAMPLENO.CONTENT DENSITY LL PI CLASSIFICATION a DESCRIPTION I TP-Rl #4 <;;F I GRAVeL WITH SOME S.i\ND AND SCATTERED COBBLES : PROJECT NO.052506 RIVER ALLUVIUM TEST PIT TP-R1 DRAWN BY: APPROVED BY: DATE:11-6-81 P.T. T.1. 90 o 10 20 30 -J;;; DO 'ii 40 3t >. .0 80 L. 50 Gl<II L.oou 60 -C Gl U 70 ~ 0001 1000.00150.010.05 200 270 Hydrometer 01 80 10040 0.15 20104 1510 u.S.Standard Sieve Number s !l() ~2 11/2 I ~/4 1/2 ~/8 1001500 u.s.Standard Sieve OpenlnQs in Inches 12 9 6 .---.---,-- IlIlI'.I I I I I I I I \ ) "\ I I\., \ ~ I \ \ I \ ro.. ") Iil......r-.... ........... .............) --'I "- r"'Q i'.. ............ ~Ii ---0'000 80 Q;50c u.. 90 20 10 100 70 30 >. .0 -J;;; <:JI Gl 3:60 -~40u... Gl Q. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-Rl #5 GP GRAVEL vIITH SOME SAND AND SCAT RIVER ALLUVIUM TEST PIT TP-R1 DRAWN BY:P •T. APPROVED BY:T.I. DATE:11-6-81 PROJECT NO. jJ ]~~>])J .c ....J ,......J ,J ~~):--')~-l '-'"J "-~'-J )'C)')']]""j ....,.~]~'J .1 o 30 10 20 90 .- ~ CII 'iii 40 ~ >..a L. 50 <IIl/l....oou 60 .-c <II ~ <II 70 Cl. 80 0001 100o.oms0.010.05 200 270 Hydrometer 01 80 10040 O.!l 20104 !lKJ u.S.Standard SI,,,e Numb,r s !lO 3 2 11/2 I 3/4 1/2 3/8 100!loo U.S.Standard 51,,,,Openings In Inch .. 12 9 6 ... I I II I I II I I 1\ I ~ \ 1\ ~ \ I '\ \ "-i\.. "- ..... ....a..., ----E)"""-c '"--- r--................ .............. ""'----- 0 0 1000 80 100 90 Q;50c u:: 20 >. ..Q 10 70-~ at <II ~60 -~40u "- <II Cl.30 BOlLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes ~ISAMPLENO.CON%~T""DENSITY LL PI CLASSIFICATION B DESCRIPTION ~--- TP-R.?#1 GP.I GRAVEL 'UTll ..:>",ME ,.:>AND AND '-'xOJ,.L+,!~"-WU '-'VUUUL>>.!I RIVER ALLUVnT~1 TEST PIT TP-R2 DRAWN BY:P •T. APPROVED BY:T.1. DATE:11-6-81 PROJECT NO.05250fJ U.S.St"ndord Sieve OpenlnQs in Inch..U.S.Standard Sieve Number S Hydrometer >...c o 10 20 30 90 -c: 01 'Qj 40 ~ "- 50 ~... CIou 60 -C Q> ~ Ol 70 0... 80 0001 1000.0050.010.05 2.00 270 01 80 10040 0.5 20104 5K)!50 3 2 11/2 I 3/4 1/23/8 100 12 9 6 MO --.---._- I '\I II I I I I ~ I \ ~ G I \ I ~, \ I \. '\ )lit "- I "'-i' )"I I"-. """"~~--r-----~ ~0 1000 30 70 80 100 Q;50c 10 20 -s;:; 01 Q> ~60 90 >. .0 G:-:ii 40u... Q) 0... BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT Y DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R2.#2 GP GRAVEL \VITH SOME SAND AND SCATTERED COBBLE,S RIVER ALLtJVIllH TEST PIT TP-R2 DRAWN BY:P.T. APPROVED BY:T.1. DATE:11-6-81 PROJECT NO.052506 J J ~.~~~)~.J ~'.•_J }J -~i"J _J ~J J ]-J ~-l ))j ]') 90 o 10 20 30 -.r::.co·iii 40 ~ >, .Q 80 50 t...g u 60 -c:: Q) u... ~ 70 Cl. 0001'00o.omi0.01O.O~ Hydrometer 200 270 01 80 10040 O.~ 20104 ~10 u.S.Standard Sle.,Number S !IO 3 2 11/2 1 3/4 1/2 3/8 100~oo u.s.Standard SI,.,OpenlnQs In Inches 12 9 6 1 1 I If IT I L ~RI TT r 1'1 '"\ I I I 1\ III I I 1-I .............- 1 I T I f1 I I I ) \ II I '\ I - ,~ , \ - 0 r\ \ ) \ -, " - )t-... ) .......r--.... ~ - --- - I I ....'" I II I '"I ~~ - - I I01000 80 100 20 10 90 30 70 Q;50c:: u:: -~ a> Q) ~60 >...c -~40u... Q) Q.. BOLt.DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI CLASSIFICATION ~DESCRIPTION ,TP-R~GP GRAVEL WITH SOME SAND RIVER ALLfTVTUM TEST PIT TP';:;R3 DRAWN BY:p •T. APPROVED BY;T.I DATE:11-6-81 PROJECT NO.052506 u.s,Standard Sllvl Openings in Inches U,S,Standard SilvlNumber s Hydrometer >. 4:l o 30 10 20 -.c:. 01 'il 40 ~ 90 80 "- 50 ~.... Q Q U 60 C III (J.... III70Q.. 0001 1000.0050.010.05 200 270 01 80 10040 0.5 20104 5Kl50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 --.-..........--- II II I I I I I 1\ 'til I r\ ~ I \ \ I "\, \ \. '"), ) 1'\IQ. I""--.I'-..... )~I....... r--.......I~'"........ r--..... --0 1000 80 70 20 10 -.c 01 III ~60 >- .Q :u 50<:: u.. 30 100 90 -~40u.... III Q.. BOLLDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY 'P-R4 #2 LL PI GP CLASSIFICATION 8 DESCRIPTION RIVER ALLUVIUM TEST PIT TP-R4 DRAWN BY' APPROVED BY:T.r. DATE:11-6-81 PROJECT NO. .~J ~I J J ])'.J ,J ..,J )J ])..J 1 ~'~'l '}--"-"'1 '~---l ).",--'}-')-'.]_..")'1 ] u.s.Sfandard Sieve OpenlnQ.In Inch••u.S.Standard Sieve Number.Hydrometer o o 30 20 90 ... ,&; 01 40 ~ >..a 80 "-50 QlIII....oo (j 60 ... C Ql ~ Q) 70 Q.. 0001 1000.0050.010.05010.551050100500 12 9 6 3 2 11/2 I 3{4 1{2 3{8 4 10 20 40 80100 200 270,I I'I II I I , I ~ I \ '\ I I '\, I t>, '\. I -, ..... "I 1'\", I "~ "'-'"I'..)"" I I;l -~r-t-. ""'-e.- 0 1000 10 30 20 100 70 -~40 l"l '- Qla.. 80 90 -,&; C' Ql ~60 Gi 50c i.L >..a BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT y DENSITY LL PI CLASSIFICATION 8 DESCRIPTION _'TP--R5 #1 @J SANDY GRAVEL RIVER ALLUVIUM TEST PIT TP-R5 DRAWN BY:p APPROVED BY:T.I. DATE:11-6-81 PROJECT NO.052506 u.s.Standord Sieve Opening_in Inches u.S.Standard S18.e Number_H ydrameler o o 20 30 90 80 0- ~ '"'jjj 40 ~ >- .Q ..... 50 ~.....oou 60 0- C G>u..... G> 70 a.. 0001 100 0.00!l0.010.0!l 200 270 01 80 10040 O.!l 20104 !l()!l0 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 !l00 .---.---._- I I ,II I I I II I )1\ '\ I : "- )\. ~ )'\ "\. ~ \ I "- I "Itt ~ I "I."'""I-r--.. ............'-'- --0 1000 90 20 100 30 10 70 80 >- .Q 0- ~40u..... G>a.. 0- J:: 00 G> :0:60 Q;50c iL BOULDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION TP-R5 #2 GW SANDY GRAVEL WITH SCATTERED COBBLES RIVER ALLUVIUM TEST PIT TP-R5 DRAWN BY: APPROVED BY:T.I. DATE:11-(';-81 PROJECT NO.052506 J L.,.__l .",..J 'J ,).J J 'J )......J c,.J }) '1 ---~J -~l "1 -)--1 "l --)"")'e'}-~c...-].)C) us.Standard Sieve OpenlnQs in Inches u.S.Standard Sieve Number S Hydrometer o o 20 30 90 80 -4- 01 Qj 40 :it >-.0... 50 ::...oou 60 -c: Q) ~ OJ 70 CL 0001 1000.0050.01O.O~01O.~~!O~O100~oo 12 9 6 3 2 11/2 I 3/4 1/2 8 4 10 20 40 80 100 200 270 I I I I -~-I I I I 'I- ---(i.~ '\ I '\.: \ ~ \.\ ~ I 1\ \ )\ )1'\I\ ~ 1'-1'- .......!I--0 1000 10 20 100 30 70 80 90 ~50c: LL-~40u... Q) CL '".a -4- O' Q) 3=60 BOUlDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I CONTENT y DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R6 #2 ML-SM SILTY SAND ._-~_.I (FIELD GEOLOGIST NOTES TRACE ORGANICS) RIVER ALLUVIUM TEST PIT TP-R6 DRAWN BY:P.T. APPROVED BY:T.I . DATE:11-6-81 PROJECT NO.052506 u.s.Standard Sieve OpenlnQs in Inches U.S.Standard Sieve Numbers Hydrometer o o 30 20 90 ...r- Ot 'ii 40 ;t >. .,Q 50 ~ L-oou 60 ...r::: CLl ~..70 (l 80 0001 100O.OO!!0.01O.O!! 200 270 01 80 10040 O.!! 20104 !!k)!lO 3 2 11/2 I 3/4 1/23/8 100 12 9 6 !!oo ...---.----........ I i''I I II I I I I I \I\- I \ \ ,1\ \ Il!l \ I \ \ 1\ I 1\ I 'e.. .........r-...... I ~E......Ie~ ""<oil .........~ i'......... ............0 1000 80 70 100 10 30 20 90 >. .,Q ...r- Ot Ql 3:60 ~50c lL... ~40u... Ql (l BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. y CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R7 #1 GW SANDY GRAVEL RIVER ALLUVIUM TEST PIT TP-R7 DRAWN BY:p APPROVED BY;T.I. DATE:11-6-81 PROJECT NO. ..~J ...,.}~.]J J ~~}c._.)]J "I ) co""...J ) ---)---]-)')")-}~)'):~]~J ---)) U.S.Standard Sieve Openings in Inches U_S.Standard Sieve Number s Hydrometer o o 30 50 20 -.c 0>'«; 40 :it >. -0 90 80 ... Q) '"L-aau 60 -c Q) ~ II> 70 11. 0.001 1000.0050.010.05 200 270 0.1 80 10040 0.5 20104 5KJ50 32 11/2 I 314 1/2 3/8 100 12 9 6 500 -,--'rII,II I I II I \D-. --, I-G "~ I .......~----..:.-.-q \ \ r-.. \ I 1\- ~ I \ \ I 1\ )\f\ '\ -~ 0 1000 90 80 100 10 70 20 30 -~40 <.> L- Q) lL >. -0 -.c 0> Q) 3:60 ~50c: LL BOULDERS I COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes -~---_._--' SAMPLE NO.PI CLASSIFICATION a DESCRIPTION TP-R7 #2 -SP I SAND vUTH SOME GRAVEL RIVER ALLUVIUM TEST PIT TP-R7 DRAWN BY:P •T. APPROVED BY:T.I. DATE:11-6-8 PROJECT NO.052506 US.Standard Sieve Openings in Inches U.S.Standard Sieve Numbers H ydrameter o o 30 50 20 -.c '"i) 40 ~ >. .Q 90 80 .... Ql III....oou 60 -C Ql:: Cll 70 CL 0001'000.0050.010.05 200 270 01 80 10040 0.5 20104 5o50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 ---.---._-,II I ,II I I I )~I 1\,,, ", '\ \ I'a .......~I '\. I '\ )""'-........r--.....)i.......r---r--.....M .......-, ~ --0 1000 90 100 30 70 20 80 10 >. .ll -.c 0> Ql 3:60 Q;50c LL ~40u.... Cll CL BOULDERS COBBLES Coarse GRAVEL Fine Medtum SAND Fine FINES Silt Sizes SAMPLE NO.Y CONTENT I DENSITY LL PI CLASSIFICATION B DESCRIPTION I "'TP-R8 #1 I I I I I GW ~_~~VEL _\tJIT.!:!__sm1E SAND AND SCATTEREn....~OBP,LES I RIVER ALLUVIUM TEST PIT TP-R,9 DRAWN BY:P •T. APPROVED BY:T.r. DATE:11-6-81 PROJECT NO.052506 "..c__,;;}--,I ~J ...c.·J J J J ,.l ..c)J )--~)'J ")')"J l u.s.Standard Sieve Openinos in Inches U.S.Standard Sieve Numbers Hydrameter '".a o o 20 30 90 50 -.&: 01 ii 40 :;t "-OIl III Qou 60 C IIIo "-11l70Q. 80 ZOO 2708010040ZO1043ZIIIZI314liZ3/8IZ9 6 .---.---._- II I "'I I II I \ \ I \ \ \ I \ I \ \ )\ \I I ) I~, :"I\. "-" 30 70 100 10 90 '".Q ~50<: LL 20 80 -.&: 01 OIl 3:60 -~40o "- IIIa.. 0'000 !l00 100 !IO 10 !I O.!I QI 0.05 0.01 0.005 QOOI'OO BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes I SAM PLE NO.I ~g~\l~~E I DR~siTY I LL I PI I CLASSI F ICATION B DESCRI PTION I TP-R9 #1 I I_~I I SM I SAND HITH SOME SILT _~·"m._·__··___I (FIELD GEOLOGIST NOTES TRACE ORGANICS) RIVER ALLUVIUM TEST PIT TP-R9 DRAWN BY:P.T. APPROVED BY:T.I. DATE:ll-G-81 PROJECT NO.052506 u.s.Standard Sieve Openings in Inches U.S.Standard Sieve Numbers Hydrometer o 10 30 20 -.c 01 'iii 40 ~ >. .0 50 80 ... III 011.. CJou 60 -C III:: III70a.. 12 9 6 3 2 11/2 I 3/4 1/23/8 4 10 40 80 100 200 270 r I II I I ~I I I \ \ I \ \ , I \ \ \ \ \ \ ~ I ) )I20 30 70 80 90 100 -.C- Ol '0; ~60,., .Q Q;50c i.i:-~40o..... II>a.. 10 90 0 1000 !l00 100 !lO Kl !l O.!l 01 0.05 0.01 0.005 0001 100 BOu..OERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION 'TP-RlO #1 SM SILTY SAND RIVER ALLUVIUM TEST PIT TP'"'"R10 DRAWN BY: APPROVED BY: DATE:11-6-81 PROJECT NO. j J "-")~),.J J )J .J ..J -1 --)/"..-..r"-·-l ..""-)~--h~)A_-l 1 ~"'-1 ) u.s.Standard Sieve Openings in Inches u.S.Standard Sieve Number s Hydrometer o o 20 30 ....c 0> "Q; 40 ~ ]; 90 80 50 i......oou 60 ...c Q) ~ III 70 CL 0001 100o.om;0.010.05 200 270 0.1 80 10040 0.!5 20 .104 ~k)~O 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 ~OO --'-I I II .- II I III ."-1---- I I I"'\. 1\ : "'lit -t--. I r..... 'Iil.I ~ .....) r""olil... ,....'- - ) r\ 1\ ) \. '\ I .._-. '\ \ I I 1\ .~"'" ) :1 ~ 1......t--... -........ J:.I -~~0 1000 90 80 -.s;: 0> Q) ~60 20 70 10 100 30 >-..0 -~40u.... Q) 0... ....~50 ii: BOl.l..DERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION ,TP-RIO #2 SM-SP GRAVELLY SAND WITH SOtm SILT RIVER ALLUVIUM TEST PIT TF-RIO DRAWN BY:P • T • APPROVED BY:T.I . DATE:ll-G-81 PROJECT NO.052506 US.Standard Sieve OpenlnQs In Inches U.S.Standard Sieve Numbers Hydrometer o 10 30 20 90 80 .....s::. 01 ii 40 3: >..c "-50 Q)~cou 60 -c Q) ~ 70 If QOOI'OO0,0050.010.05QI0.55Klw100!lOO 12 9 6 3 2 11/2 1 3/4 1/2 3/8 4 10 20 40 80 100 200 270 I I II I II I II I I I I )\. \ \:I r\ \ I \ \ "- I \ \ \ I r-....... 'D.....~I r-..r-- )r-.1r""l ....... """~-... 10 0 '000 30 -.c Cl Q) ~60 20 70 100 80 90 t 50c lL >..c -~40 l).. Q.l Q BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.y CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-Rll #1 GP SANDY GP-Ayt RIVER ALLUVIUM TEST PIT Tp:"Rll DRAWN BY:P •T. APPROVED BY:T.I. DATE:11-6-81 PROJECT NO.052506 --l J 1 ..1 OJ ))v")J J),~t \..J 1 J ""I 'I 1 -"".')}-""-"J --,")"1 1 ........"-) lI.S,SIQndgrd &IIVI Cll*1ln\l'in Ino~.~V·fI·SIQn<lgr4 61'V'N~mPlr.thdrqm111r p Q 20 30 90 +-s:::ao i 40 ;t ~ 80 .... 50 Gl'"....oou 60 +-c IIIu... II70CL 0001 100O.OO!I0.010.0501O.l:i!I10!IO100!l00 I 9 fi J 2 Ii/il 1.114 1/2 ~Ii!'a 2 ~I 80 100 ilOO 210 1 1 ~I'I ,I'..It·II ... .-- " ._. I...._....--:...........~._.._..-........-".,._.-,...c- \,_._.'.I-c.:....._-..-.~ .-- , 1\:, , "I \ "I "'\ > '" )".............. ~'--)-(ill-- I ~ f"'1 """-. ~ 0 1000 10 ....~50 20 U- 91:) 70 80 ~ 100 >. ..0 +- ~ 00 Gl ~GO -~40u... Gl CL BOlJ...DERS COBBLES GRAVEL Coorse I Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION :TP-Rll #2 GRAVEL WITH SOME SAND RIVER ALLUVIUM TEST PIT TP-Rll DRAWN BY;P •T. APPROVED BY:']'.I . DATE:11-6-81 PROJECT NO. us.Standard Sieve Openin~s in Inches U.S.Standard Sieve Numbers Hydrometer >. ..Q o o 30 20 ....c 01 'il 40 3: 50 90 .. Ql III L.oou 60 ...c:: Ql u.... Q) 70 0.. 80 0001'000.0050.010.05 200 270 01 80 10040 0.5 20104 5()50 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 --.-- I r"II I I I I I I ~ \ I \: ~ I \ 1\ I '\., i'. I \. ", ~ I '0.... ~'--G-r- )-"-<:I'"'"Il~ G 0 1000 30 20 tOO 90 80 10 70 >. .0 L.~50 ~ ... &; 01 Ql ~60 ... ~40u....., 0... BOLA..DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.Y CONTENT I DENSITY LL PI CLASSIFICATION 8 DESCRIPTION I .TP-R12 #l I I I I I GP I SANDY GRAVEL .-..I RIVER ALLUVIUM TEST PIT Tp':"R12 DRAWN BY: APPROVED BY: DATE:11-6-81 PROJECT NO. )1 1 "cJ',l ),-)..c.1 J J'c) ·)~c._.].,c._"},f._eJ "J Of--)""1 -)....,")---1 "'1 ....•..)~'l 1 u.s.Standard Sieve Openings in Inche.U.S.Standard Sieve Numbers Hydrometer o o 20 30 90 ....c. Ol iii 40 ~ >. ..Q "-50 Q>"'...oou 60 ...c: I])u... I]) 70 0.. 80 0001 1000.0050.010.05 200 270 0.1 80 10040 O.!l 20104 5KJ~ 11 2 11/2 I 11/4 1/2 11/8 100 12 9 6 !lOO ... r i 1\I If I I I II, ~ I \ \ \ 1\ \ ~ I "\ "I 'I'-.. "il.....I ........ ............ )'---I........ ~..... .~I· ~ 0 1000 90 80 100 10 20 30 70 -~40u !o- I]) 0.. -.c. Ol Q> ~60 >. ..Q ~50c: ii: I COBBLES GRAVEL SAND FINES BOLLDERS Coarse Fine Medium Fine Silt Sizes SAMPLE NO.pq=:--I--'-~ANDY GRAVEL CLASSIFICATION B DESCRIPTION TP-R;l~#2 RIVER ALLUVIUM TEST PIT TP-R12 DRAWN BY:D •T_,I APPROVED BY:T.I . DATE:11-6-81 PROJECT NO.052506 U.S.Standard Sieve OpeninQS in Inches U.S.Standard Sieve Numbers Hydrameter 10 o 20 30 90 -.c: 01 'il 40 ~ >. ..Cl 80 .... 50 Gl......oou 60 -C Gl U "-III 70 a.. 200 270eo10040201043211/2 I 3/4 1/2 3/e129 6 .---.-....-.....- I I ~r-.I I I I I I I~ , \ I \ \ \ 1'\ \ '" i' ) ~ )~ "'") I-o~: r--. ~ ........... "- 10 -~ 01 Gl ~60 100 90 80 20 30 70 :»50cu:: >. ..Cl -~40u '- Gla.. 0'000 500 100 50 Kl 5 0.5 01 0.05 0.01 0.005 0001 100 BOu...DERS COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes I MOIS10REI DRY I LL I PI I~CLASSI F ICATION B DESCRIPTIONSAMPLENO.CONTENT DENSITY I _. TP-R13 #2 SANDY GRAVEL RIVER ALLUVIUM TEST PIT TP-R13 DRAWN BY:p APPROVED BY:T.I. DATE:11-6-8)_ PROJECT NO.052506 .J J ""J J 1 .....J ),J I )I ...•]j .J '1 }....]'C"'),..)(-'-]-~-).-'°--1 /-.'-t -")-')"'1 "---1 l. U.S.Standard Sieve Openings in Inches U.S.Standard Sieve Numbers Hydrometer o 20 10 30 90 -L: 0> 'il 40 ~ >. .Q 80 .... 50 CIl~ Cou 60 -<: CIl ~ '"70 a.. 000,100o.OO~0.010.05 200 270 01 80 10040 0.15 20104 15I)~ 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 ~oo 20 30 10 0'000 80 90 70 100 >. .Q -~40u.... QIa.. -.&: a> QI ~60 Q;50<: i.L BOULDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM P LE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R14 #1 Glv SANDY GRAVEL RIVER ALLUVIUM TEST PIT TP"'-R14 DRAWN BY:D.T. APPROVED BY:T.I . DATE:11-6-81 PROJECT NO.052506 U.!i,SIQndgr~Slev.Openings in Inch ••\-l.S.Ejlandgrd §I.v.N~mb.r.H Ydrllme,~r 90 o Ifl 20 30 ...s::. 01 'i 40 ;t >-... 80 L- 50 : L-aou 60 ...c II>u L- II> 70 0... 0001 1000.0050.010.05010.55(l50100500 12 9 &;\j ,a I 114 IIi!I'l 4 I~20 40 110 lOCI to l!7Q _. I I ~II '1 1 I ,.-I I II I! ...c-----e---~- " ---- ----_._.-- 1\:1---f----_-----::_'-:..f-_---,---.-_.---- i I ~., I \ I \ \. I , "I "- )'r-.. "'Ia I ........ ~...... )----.......... Q ....~ .......j"'G ............. ~Ie 10 0 1000 >. .0 20 100 70... .J:: Cl <i> 3:60 80 80 30 -~40u.... II> 0... L-~50 iL BOU-.DERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY TP-R14 #2 LL PI GP SANDY GRAVEL CLASSIFICATION 8 DESCRIPTION RIVER ALLUVIUM TEST PIT TP-R14 DRAWN BY;P •T. APPROVED BY;T.I. DATE:11-6-81 PROJECT NO. J ~I )J ~')'1 ')'e},-]),-.-'l r --'t "1 -.'-1 90 o 10 20 30 -.r::. 0> 'ij 40 ~ >. .Q 80 50 ~ '-cou 60 -c: I)o.. III 70 ll. 0001'00O.OO!I0.010.05 200 270 Hydrometer 01 80 10040 0.5 20104 510 U.S.Standard Sle.e Number S 50 3 2 11/2 I 3/4 1/23/8 100500 U.S.Standard Sle.e OpenlnllS in Inches 12 9 6 --....... I --- I•I "'-IT I f\.. 'I I'I I I " I -- ~ ~ I \ -\ - ) \ -, \ - I - - I 1\ I 1\ e_ r\ ) \ \ ) 1\ \ ) _e_I01000 100 80 30 20 10 90 70 :u 50c: u::: >..a -.r::. 0> Q) ;t 60 -~40o '- Q) 11. BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.Y CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R15 #2 SM SILTY SAND (FIELD GEOLOGIST NOTES TRACE ORGANICS) RIVER ALLUVIUM TEST PIT TP-R15 DRAWN BY;P.T. APPROVED BY;T.I. DATE;11-6-81 PROJECT NO. u.s"Stondord Sle..OpenlnQ!in Inehn U.S.Stondord Sieve Number I Hydrometer >-.c o 10 20 30 .....c 01 i 40 ~ 80 .. 50 Ql......oou 60 -c: Qlu... Ql 70 Q. .-----..,-.~...,--,-.----................---_.- I I I'II "I\. I I II )"'I\. I '\. ~\..., \ \ \. \ I I ~ ) )I 30 20 70 80 -~ 00 Ql ~60 100 90 >- .Q Q;50c: iL-~40u... Ql Q. 10 90 0.010'000 ~oo 100 ~Kl ~O.~01 0.05 0.005 0001 100 BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT"I OENsiTY I LL I PI I CLASSI F ICATION a DESCRI PTION I TP-R16 #1 I I I I I SM I SILTY SAND ---.---------t (FIELD GEOLOGIST NOTES TRACE ORGANICS) RIVER ALLnVIUJ-l TEST PIT TP-R16 DRAWN BY:P •T. APPROVED BY:T.I . DATE:11-6-81 PROJECT NO.052506 ~jJ J ..1 ~J ','._)J _--.1 J ..._J J <]J ~.} ~1 OJ U.S.Standard Sieve OpenlnQs In Inches U.S.Standard Sieve Number S Hydromet~r 90 10 20 30 o 80 .....c:: 0> 'iii 40 ~ >...c "-50 CIlOIl L-ao U 60 ...r::::eu ~ 70 tf 0.00,1000.0050.010.05 200 270 Qf 80 10040 0.5 20104 51050 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 fn I 11 'I II II~I I I'I ,I'I IT P I I I T I'G •II rr I ....-......- \ ,II I )\ I I , I - \, I \, ) '\:, '\ - ) . ~ ) ........ ~" -----i )"r- ........ I ........""" II I I -: .-- ............i'-\-."'" I I I I I I I I I I I I I N-t--.J, - I I ----'0 1000 90 30 80 10 L-~50 LJo 20 70.... '=0> CIl ~60 100 .... ~40u L-eua.. >...c BOLLDERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAM PLE NO.I CONTENT I DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R16 #2 ,GW-GM SANDY GRAVEL WITH TRACE SILT RIVER ALLUVIUM TEST PIT TP-R16 DRAWN BY:P.T. APPROVED BY:T.I DATE:11-6-81 PROJECT NO.052506 L:.S.Standard Sieve Opening.In Inche.U S.Standard Sieve Number.Hydrometer -.r::. '"'ii ;t,., .Q... I1l til....e 0 U-c: I1lu... Q) 0.. o o 30 20 70 40 50 90 60 80 000,1000.0050.010.05 200 270 01 80 10040 0.5 20104 5()~ :3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 500 .~-~.~----- I I ~I'I II I II I I I II I 1\I, I ~ I \ 1\ \ II \ \ , 1'\.f---- )'\..4"" f r--" Q"", )~I"'-l .............~ I"'- """I"'-&.-......I'-... ""'-a.... °,000 90 100 70 10 20 -.c 0> I1l ~60 80 30 >- .0 -~40 u.... ID 0.. Qj 50c: lL BOULDERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.I ...---- TP-R17 #1 y CONTENT I DENSITY LL PI Q'l CLASSIFICATION a DESCRIPTION GRAVEL InTH ,SOHE SAND AND SCATTERED COBBLES RIVER ALLUVIUM TEST PIT TP-R17 DRAWN BY:P.T. APPROVED BY:T.I. DATE:11-6-81 PROJECT NO.nS?SD6 J J ..~J J "J .J J I ..J ...J ,..1 ];".].J t '1 ~--)-1 ",'1 '-1 ,1 -1 1 --J OJ 1 U.S.Standard Sieve Openln~s in Inches u.S.Standard Sieve Number s Hydrometer >..a o o 20 30 90 +-.c '"'ij) 40 3= 50 ~.. L..oou 60 +-c: 1Ilu 70 ~ 80 200 270801004020104:3 2 11/2 I :3/4 1/2 :3/8129 6 .--- I I i\",r I I I' f\I i\. I ~ \ I \. '\. '\ '"""- .... I 'lil. 1"-........" """"c .............)....Ii. .......'Q.. )f........r-..... ~I......i--G 30 10 100 70 80 90 20 +- ~40u L.. 1Il CL +-.c 0> 1Il 3=60 >-.a L..~50 u:: 0 1000 ~oo 100 !50 10 5 0.!5 0.1 0.05 0.01 0.005 000,100 BOU.-DERS I COBBLES GRAVEL SAND FINES Coorse Fine Medium Fine Silt Sizes SAMPLE NO.CLASSI F ICATION 8 DESCRIPTION ---- TP-R17 #2 SANDY GHAVEL WITH TRACE SILT RIVER ALLUVIm1 TEST PIT TP-R17 DRAWN BY n •T • APPROVED BY;T.I . DATE:11-6-81 PROJECT NO.-0"5-2 u.s.Slandard Sieve Openings in Inches u.S.Standard Sieve Number.Hydrometer o >. .0 90 o 20 30 80 -.s:::. 0> ii 40 ;t 50 ~III L-ao U 60 -c Q;. ~., 70 0... 0001'00 200 2708010040201043211/2 I 3/4 1/2 3/8 100 !lO 0 !5 I 0'!5 01 0.05 0.01 0.005 COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes MOIsTURE I DRY pq PI I CLASSI F ICATION a DESCRIPTIONDENSITY~:- I CONTENT GP SANDY GRAVEL 12 9 6 !SOO .---'---._- I [~I II I I I I ---- I ~ '\ "I-- 'O. j "I ~ '\ I "-'\~ I 1-'.. \ I ',- i'r-... .........r--...) '") lil,r-. "I~......... ~ ~01 0'000 70 20 80 -.r; 0> <I> ?;:60 100 10 90 30 SAMPLE NO. BOUlDERS >. .0 -~40 () '- <I>n.. L-~50 LL TP-R18 #21-1-- RIVER ALLUVTfTIvl TEST PIT TP-R18 DRAWN BY:P APPROVED BY;T.I . DATE;11-6-81 PROJECT NO.052506 ,J ].:..._....J .,1 .J J "J ,~.1 .1 ».J .,J J -;----1 1 ,----1 1 ·---1 ---)'--1 -'-1 "1 o 20 10 30 90 ....c 01 i 40 ~ >. ..Q "-50 IIIII "-Dou 60 ....c: Q) l) 70 ~ 80 000,1000.00!50.01O.O!! 200 2:70 Hvdromlter 01 80 10040 O.!! 20104 !!() U.S.Standard Sllvl Numbers !lO 3 2 11/2 1 3/4 1/2 3/8 100!!OO u.s.Standard SII"I Openings In Inchls 12 9 6 -.-.. I I ..........~I I I I I I '''''a 'Cil......... -........ ) ~Q. "'-........, I '\ "I '\ I \ )1\ )\I~ r-....I~"-~ .--0 1000 20 80 10 30 70 100 90 ;50c:u:: .....c 01 ~ ~60 >...a ... ~40 l) "- Q) a.. BOlA..DERS I COBBLES GRAVEL SAND FINES Coarse Fine Medium Fine Silt Sizes SAMPLE NO_CLASSIFICATION a DESCRIPTION ----- TP-R19 #2 SAND IHTH SOME GRAVEL RIVER ALLUVIUM TEST PIT -TP-R19 DRAWN BY:P.T. APPROVED BY:T.I . DATE:11-6-81 PROJECT NO.052 U.S.Standard Sieve Openlnos in Inches U.S.Standard Sieve Number s Hydramete r o 10 30 20 ....c Dl 40 ~ >-.,Q 80 ... 50 IlOIl....oou 60 ...c: 4> U.... Il70a.. 200 2708010040201043211/2 I 3/4 1/2 3/8129 6 .---.---._- I I I I 1 I I I i"o ~I I \ \ 1\ \ \ \ ) \ )\ '\ )\ \ )I ~ 70 100 90 30 80 20 ....c 0> 41 ~60 >-..c .... ~50 iL... ~40u.... 4>a.. 10 90 °1000 ~OO 100 !lO 10 ~O.~QI 0.05 0.01 0.005 QOOIIOO BOu..DERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO. TP-R2Q #1 LL PI SM-SP CLASSIFICATION a DESCRIPTION SAND ~nTII SOHE SIL'T'AND TRACE GRAVEL.__.___I (FIELD GEOLOGIST NOTES TRACE ORGANICS) RIVER ALLUVTPM TEST PIT TP-R20 DRAWN BY;P .T. A PPROVED BY:T.1, DATE:11-6-8 PROJECT NO.0, .J .,J ',I J J ,.1 J ..J J ".J 1 ~c-"'1 ~~'l FO~~'J ,e",,,'1 <'.'.']]'1 -]"'J C .)]1 ~]1 »~ u.s.Standard Sieve OpenlnQs In In ches U.S.Standard Sieve Numbers Hydrameter 90 10 20 30 o 80 .... 50 :: '-oou 60 -c: II>u.... Q,l 70 [L -.c::. (Jl .~ 40 ~ >. ..Q 000,100o.om;0.010.05 200 270 01 80 10040 O.!l 20104 510!l0 3 2 11/2 I 3/4 1/2 3/8 100 12 9 6 !l00 1-I!(II ) I .- 1Iilt-.. r1 I f'-",- "'li; I \1:. I \ ,"._" " J " -: \ I \ '- 0 "- -- I '......., 1---..- c---. I ) "':::: -----j I ...... I .., I I Is;: : _.. II I ~ I ~0 I I 0'000 30 80 100 20 10 90 70 ~50c: u. -.c::. 0' II> 3:60 -;40 u '- II> [L >..a BOLt.DERS COBBLES Coorse GRAVEL Fine Medium SAND Fine FINES Silt Sizes ~I MOISTUREI DRY I r I ISAMPLENO.CONTENT DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R20 2 GH RIVER ALLUVIW1 TEST PIT TP-R20 DRAWN BY:P.T. APPROVED BY:T.I • DATE:11-6-81 PROJECT NO.U::':?506 US.Slandard 51.".Open In os In Inches U.S.Standard SI."e Numbers Hydrometer >. .Q o o 20 30 ...c 01 'ij 40 ~ 90 .. 50 IIIIII...oou 60 ..c: III ~ III 70 0.. 80 200 2708010040201043211/2 I 3/4 1/2 3/8129 6 _...--- I II I I II I I I Iil )I ) );; "\ ~I' "R , "'-......... I ....r--,~ I ....~-r-<lI "-I)." )"I"- ~ r--................ 40 80 20 50 90 30 10 70 60 100 .. ~ Ol,r 'iii'/~ >- .Q "- IIIc: lJ.... c: III U... III 0.. 0.0101000500100!IO KJ 5 0.5 01 0.05 0.005 0001'00 BOl.A...DERS COBBLES Coarse GRAVEL Fine Medium SAND Fine FINES Silt Sizes SAMPLE NO.CONTENT Y DENSITY LL PI CLASSIFICATION a DESCRIPTION TP-R22 #1 GP-GM SANDY GRAVEl,WITH SOME SILT AND SCATTERED COBBLES I RIVER ALLUVIUM TEST PIT TP-R22 DRAWN BY;LT.M. APPROVED BY:T.I • DATE:12-81 PROJECT NO.05250E; 1 ~.~.~J .J "....J ~......,..J ,.1 .,.1 .J J .•J ._~"I J .J J J f t 1 " \1 "~'1 "-"--1 '-'--'1 --'~I ----I -----1 ']--"1 j U.S.Standard Sieve Openln~.in Inch..U.S.Standard Sieve Numbers Hydrometer >...a o o 20 30 90 ....c:: CI' 'i 40 ~ 80 50 Q;III... Qou 60 ... C 0> U ~ Q) 70 CL 0001 100O.OO!50.010,05 200 270 01 80 10040 0.!5 20104 5KJ!50 3 '2 11/2 I 3/4 1/2 3/8 100 12 9 6 !500 .- II I rT I rr I I I 10 !\II\ -, I \: " ~ \ \ 1\ , I \.. ~ l \ \ '- '. \\. ")Iil....I r-.... ~~I i ... ~ I -...;;::::"-::... 0'000 30 90 100 80 70 20 10 >...a Q;50c: LL... ~40u ~ <1> lL ... ~ ""0> ~60 GRAVEL SAND FINES BOULDERS I COBBLES Coarse Fine Medium Fine Silt Sizes SAMPL~~g~~l~~EI o~:sYTY F~~I----~---CLASSIFICATION a DESCRIPTION TP-R22 #2 G~CPAVEL \'i1ITH SOHE SAND AND SCATTERED COBBLES RIVER ALLUVIUM TEST PIT TP-R22 DRAWN BY;P.T. APPROVED BY;,T.1. DATE;11-6-81 PROJECT NO,052505