Loading...
HomeMy WebLinkAboutSusita FERC Vol 10A exhibit E chapter 11 1983JSITNA HYDROELECTRIC PROJE FERC LICENSE A~")PLlCI.TION PROJECT NO.7114-0JO - "'"'I ..... "\K li'lS .S~ r!t'+) no"':'!;\34 3 BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION APPLICATION FOR LICENSE FOR MAJOR PROJECT SUSITNA HYDROELECTRIC PROJECT VOLUME 10A EXHIBIT E Chapter 11 FEBRUARY 1983 ..... ~__ALASKA POWER AUTHORITY __---' - - .~ I - - - SUSITNA HYDROELECTRIC PROJECT VOLUME lOA EXHIBIT E _CHAPTER 11 TEXT AND ApPENDICES A THROUGH H AGENCY CONSULTATION p~SUSITNA HYDROELECTRIC PROJECT VOLUME lOA £XHIBIT E CHAPTER 11 Text and Appendices A through H AGENCY CONSULTATION TABLE OF CONTENTS PAGE 1 -ORGANIZATION OF CONSULTATION PROGRAM E-l1-1 1.1 -Formal Consultation E-11-1 1.1.1 -Regulatory Requirements E-11-1 1.1.2 -Organization E-11-2 1.1.3 -Fish and Wildlife Mitigation Review Group £-11-3 1.2 -Informal Consultation E-11-3 1.2.1 -Susitna Hydro Steering C{)mmittee E-11-3 1.2.2 -Environmental Workshop £-11-3 2 -PHASES OF-REVIEW £-11-5 2.1 -Consultation Prior to Preparation of Draft FERC Appl icat ion E-11-5 2.1.1 -Plan of Study ,£-11-5 2.1.2 -Data Collecti{)n and Project Assessment E-11-5 2.1.3 -Development Selection £-11-5 2.1.4 -Mitigation Planning ....•...................•~.E-11-5 2.1.5 -Feasibility Assessment ................•.......E-11-6 2.1.6 -Additional Studies '"E-11-6 2.2 -Draft License Review f-1l-6 LIST OF TABLES LIST {)f FIGURES -Append;x EllA -Correspondence Re 1at ing to Organi zat ion of Consultation Program Appendix E11B -Corr~spondenc~Relating to Pl~n of Study Appendix EllC -Correspondence RelaUng to lJataCollection and Project Assessment Appendix ElID -Correspondence Relating to Deveiopment Selectfon Appendix El1£-Correspondence R~lating to Mitigatinn Planniny Appendix EIIF -Correspondence Re1ating to feasi~ility Assessment Appendix EUG -Correspondence Relating to Additlonal Studies and Pr-oject Refinement Appendix EllH -Comments During Nov€mber 1982 Workshop i ii TABLE OF CONTENTS Appendix Ell!-Correspondence Relating to Draft Review Appendix EIIJ -Comments Received from Agencies Concerning the Draft License and the Power Authorityls Response to These Comments LIST OF TABLES - Table E.ll.l E.l1.2 E.ll.3 E.ll.4 E.ll.5 E.ll.6 E.ll.7 E.ll.8 E.ll.9 Formal Agency Coordination List (original) Original List of Reports and Groups to Which Reports Were/Were To Be Sent Original List of Agencies and Reports Received Agency Coordination Expanded List Expanded List of Reports and Groups tn Which Reports Were/Were To Be Sent Reports,Date Sent,and Purpose Agencies Invited and Those Which Declined To Be On the Fish and Wildlife Mitigation Review Group Members of the Susitna Hydroelectric Project Steering Committee Dates and Purpose of Steering Committee Meetings With APA and/or its Consultants E.ll.10 Objectives of the Susitna Hydroelectric Environmental Workshops E.ll.ll Agenda of the Susitna Hydroelectric Environmental Wo rkshop E.ll.12 List of Attendees i LIST OF FIGURES - Figure E.ll.1 E.1l.2 Organization of Agency Consultation Program Agency Consultation Review Process ;; -. ,~ 11 -AGENCY CONSUL TAT roN This chapter describes the various processes util ized,and committees established by the Alaska Power Authority (Power Authority)to provide agency input into the studies and discussions associated with the Susitna Hydroel ect ri c Project.Th is agency consultati on and result i ng agency input was requested and provided on both an informal and formal basis as described below.In addition,the Power Authority conducted an extensive public participation program.For a discussion of this general publ ic participation in the project,refer to Appendix 0 of the Feasibility Report. In addition to this agency consultation described,a large number of agencies were contacted for information during the preparation of the environmental reports.This resulted in a constant exchange of ideas and updating on the project's progress. 1 -ORGANIZATION OF CONSULTATION PROGRAM Consultation with the regulatory agencies was conducted on both a for- mal and informal basis as described below.Formal consultation was conducted with the agencies as required by the regulations of the Fed- eral Energy Regulatory Commission (FERC)and was done primarily via correspondence.Informal consultation was done primarily via numerous meetings and was conducted to provide an information flow between the Al aska Power Authority,its consultants,and the agenci es to insure agency input into the project planning and decision making process. Figure E.11.1 depicts the organization of the agency consultation pro- gram. 1.1 -Formal Consultation 1~1.1 -Regul atory Requi rements The FERC regulations pertaining to applications for license under Part I of the Federal Power Act requi re in 18 CFR Part 4,Subpart E,Section 4.41,that applicants for licenses consult with local, state,and federal natural resource agencies prior to fil"jng of their license application.Accordingly,the Alaska Power Author- ity formulated a plan to consult with these agencies. The Jlrocess utili zed by the Power Authority was based upon ci rcu- lation of reports of the various aspect~of the projects to the agencies and a written request for agency comments.The reports ci rculated were i nteri m reports in speci fi c study areas (fi sher- ies,wildlife,etc.)as discussed below,as well as planning de- cision reports (access road,transmission line corridors,etc.)• .In addition,prior to initiation of project studies,the Plan of ;Study and revisions were circulated.Results of the fish and wildlife mitigation planning efforts were also circulated under E-dl-1 this formal program.Finally,a draft version of Exhibit E of the license application was provided to all agencies on November 15,1982. 1.1.2 -Organization The organization and implementation of the Formal Agency Coordi- nation Program has been a dynamic process modified because of agency input.The original organization is explained below,fol- lowed by an exp 1anat ion of the revi sed organi zat i on.Correspon- dence relating to that organizational process appears in Appendix ll.A. (a)Original Organization (i)Agency Groups Subject areas for coordination were selected based upon those required by the FERC regulations.These were water quality and use;fish,wildlife,and bo- tanical;historical and archeological;recreation; aesthetics;and land use.State,federal,and local agencies having jurisdiction over "resources in each of these subject areas were then placed in the appro- priate group of agencies which would receive reports concerning these subjects.A general category was also added to include agency involvement with policy decisions.Table E.ll.1 lists the agencies original- ly included in each of these groups. (ij)Reports Circulated Ali st of the reports and the groups to whj ch they were sent appears in Table E.I1.2.Because of over- lapping jurisdictions (one agency present in more than one group),several agencies received reports ~n different subjects.Table E.11.3 lists,by agency, the reports received. (b)Revised Organization Initial circulation of these reports resulted in feedback from the agencies concerning the organization of the for~al agency coordination program.Following several meetings be- tween the Power Authority and the agencies,t~e ~rogram was revised.The revisions included: -An expansion of the number nf groups; -An expansion of the number of agencies within each group; and E-11-2 .- - A decrease in the number of reports for which formal com- ments were requested and,instead,simply providing re- ports for i nformat i on as backup documents to reports on which comments were requested. Table E.11.4 1i sts the revi sed subject groups and the agen- cies within each group.Table E.11.5 lists the reports to be received by each group,and Table E.11.6 reports the date they were ci rcul ated and thei r purpose'(i nformation or comment).This revised program exceeds the consultation required by FERC but was implemented to insure that all agencies received adequate informatiorr. 1.1.3 -Fish and Wildlife Mitigation Review Group Throughout the Sus itna Hydroe 1ectri c Project studi es,techni cal mitigation planning has been conducted by the Power Authority and its consultants to reduce impacts to fish and wildlife resources. To insure agency input into thi s process,a Fi sh and Wil dl i fe Mitigation Review Group was established.The purpose of this group was to review fish and wildlife mitigation options pre- sented to them and provide comments on priority and practicality of their options.Agencies invited to be on this committee and those who accepted are listed in Table E.11.7. 1.2 -Informal Consultation 1.2.1 -Sust ina Hydro Steeri ng Committee The Sus itna Hydroel ectri c Project Steeri ng Commi ttee was estab- lished in 1980 as a mechanism to insure agency interaction in project progress and decision making.The first meeting was held in July 1980 and meetings continue to date.Originallyenvi- sioned as a formal process,it was decided the committee would function as an informal body with official agency comment ad- dressed via the Formal Agency Coordination Program.Appendix 11.A contains correspondence relative to the establishment of the Steering Committee.' The committee consi sts of representat ives of state and federal agencies as listed in Table E.11.8.Table E.11.9 1 ists the dates of meetings between the Power Authority and the Steering Commit- tee and the purpose of these meetings. 1.2.2 -Environmental Workshop To assist agencies in reviewing the draft Exhibit E a four-day workshop was hel din Anchorage f rom November 29 to December 2, 1-982.The objectives for the workshop agenda and a listing of participants is included in Table E.11.10, E.11.11,and E.11.12, respectively. E-11-3 2 -PHASES OF REVIEW The Sus itna studies have included extensi ve agency consultati on,com- menci ng with a request for revi ew of the Pl an of Study in the spri ng of 1980 throughto.a request for review and comment on the Draft Exhibit E on November 15,1982.The various study phases,items reviewed,and review schedule are shown on Figure E.ll.2. 2.1 -Consultation Prior to Preparation of DraftFERC License Appl icati on 2.1.1 -Pl an of Study The Plan of Study was circulated for review in March 1980,with public and agency meetings being held in April 1980.The Plan of Study was further discussed with the Steering Committee in Sep- tember 1980.In addition,Environmental Procedure Manuals were circulated for review in October 1980.Comments on the Plan of Study were subsequently received and responded to.This process insured agency input into the design and future of the study. Correspondence appears in Appendix II.B. 2.1.2 -Data Coll~ction and Project Assessment All big game and fisheries baseline data were collected by the Alaska Department of Fish and Game (ADF&G)under a Reimburseable Services Agreement with the Alaska Power Authority.ADF&G had a major influence on the direction,scope,and schedule for these studies.Annual reports for all the environmental subtasks were distributed in April-May 1981. In addition to annual environmental reports,comments were re- .quested on access road reports,transmission 1 ine siting reports, and the Sus itna Hydroe lectri c Project Mi d-Study report.Corres- pondence concerning these documents appears in Appendix 1l.C. 2~1.3 ~Development Selection In March 1981,the Development Sel ect i on Report was ci rcul ated to agencies for,revi ew and comment.Thi s report compared vari ous development scenarios.within the lower and middle Susitna Basin as well as alternatives outside the basin.Comments received on the Development Selection Report appear in Appendix 11.0. 2.1.4 ~Mitigation Planning Mitigation Planning for the Susitna Hydroelectric Project has in- volved the Power Authority,its consultants,and state and fed- eral resource agencies.A Fisheries .Mitigation Core.Group, Wildlife Mitigation Core Group (to develop technical mitigation plans)~and a Fish and Wildlife Mitigation Review Group (to pro- vide agency input to 'the mitigation plans)were established. E-11-5 A Fish and Wildlife Mitigation Policy was developed,revised three times following receipt of comments,and finalized during the 1981-1982 period.Various mitigation option papers were also drafted,circulated for comments,and discussed in meetings with the agencies.Appendix l1.E contains correspondence related to mitigation planning. 2.1.5 -Feasibility Assessment On March 15,1982,the Susitna Feasibility Report was distributed for review and comments.During April and Mayall support docu- ments were distributed.Appendix 11.F contains a 1 ist of agen- cies to whom the report was sent.Also included are agency com- ments and testimony. 2.1.6 -Additional Studies and Project Refinement In response to agency concerns and in recognit ion that further studies,especially in the area of fisheries,were warranted prior to submitting a FERC license appliction,the decision was made by the Alaska Power Authority to delay the license applica- tion date.Studies and project refinements that received agency revi ew i ncl uded the wil dl He/habitat model,water qual ity and flow modeling,access plans,and downstream flow release sched- ule.Agency consultation took the form of Steeri ng Committee meetings,habitat modeling workshop,Fish and Wildlife Mitigation Review Group meetings,and request for written comment on the re- vi sed access plan.Co rrespondence and mi nutes of meet i ngs from the above are contained in Appendix 11.G. 2.2 -Draft License Review On November 15,1982,a Draft Exhibit E of the 1 icense appl ica- tion was distributed to appropriate federal,state,and local agenci es for offi ci al revi ew and comment.Agenci es recei vi ng copies of this report are 1 isted in Table E.11.12.To assist agencies in reviewing the Draft Exhibit E,a four-day workshop was held in Anchorage from November 29 to December 2,1982.Un- official agency comments received during this workshop are in- cluded in Appendix 11.H.Following the 60-day review period, comments were recei ved from t he resource agenci es.These appear in Appendix 11.1.Comments relating to any measures or facili- ties recommended by the agencies that could mitigate potential impacts of the project are addressed specifically at the end of appropriate chapters with Exhibit E.If the Power Authority has not accepted any of these recornmendat ions,the reason s are .pre- sented. An entire set of comments,including all those relating tomiti- gation,report reviews,assessment of alternatives,and the need for the project,are included ina comment-response format in Appendix 11.J.Each comment is presented followed immediately by the Power Authority's response. E-11-6 TABLE E.11 .1 :FORMAL AGENCY COORDINATION LI ST(OR IGINAl) Water Quality and Use Group Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 Colonel Lee Nunn District Engineer Alaska District U.S.Army Corps of Engineers P.O.Box 7002 Anchorage,Alaska 99510 Mr.John Spencer Regional Administrator Region X U.S.Environmental Protection Agency 1200 Sixth Avenue Seattle,Washington 98101 . Fish,Wildlife,and Botanical Group Mr.Robert McVey Director,Alaska Region National Marine Fisheries Service NOAA P.O.Box 1668 Juneau,Alaska 99802 Mr.Ernest W.Mueller Commissioner Alaska Department of Environmental Conservation Pouch 0 Juneau,Alaska 99801 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 cc:Judy Swartz U.S.Environmental Protection Agency Mail Stop 443 Region X EPA 1200 Sixth Avenue Seattle,Washington 98101 cc:Mr.Ron Morris Director Anchorage Field Office National Marine Fisheries Service 701 C Street,Box 43 Anchorage,Alaska 99513 - Mr.Keith Schreiner Regional Director,Region 7 U.S.Fish and Wildlife Services 1011 East Tudor Road Anchorage,Alaska 99503 Mr.Ronald O.Skoog cc: Commissioner State of Alaska Department of Fish and Game Support Building Juneau,Alaska 99801 Mr.Thomas Trent State of Alaska Department of Fish and Game 2207 Shepard Road Anchorage,Alaska 99502 TABLE E.11.1:(Page 2) Historical and Archeological Group Mr.John E.Cook Acting Regional Director Alaska Office National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 cc:Mr.Larry Wright National Park Service 1011 East Tudor Road Suite 297 Anchorage,Alaska 9950~ Ms.Lee McAnerney Department of Community and Regional Affairs Pouch B Juneau,Alaska 99811 Mr.Robert Shaw state Historic Preservation Officer Alaska Department of Natural Resources Division of Parks 619 Warehouse Avenue,Suite 210 Anchorage,Alaska 99501 Recreation Group Mr.John E.Cook Acting Regional Director Alaska Office National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 Mr.Lee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer,Alaska 99645 Aesthetics and Land Use Group Mr.Roy Huhndorf President Cook Inlet Region,Incorporated P.O.Drawer 4N Anchorage,Alaska 99509 Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 cc:Mr.•Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 cc:Mr.Larry Wright National Park Service 1011 East Tudor Road Suite 297 Anchorage,Alaska 9950~ cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 I~ TABLE E.11.1:(Page 3) Aesthetics and Land Use Group (cant/d) Mr.John Rego Bureau of land Management Anchorage District Office 4700 East 72nd Avenue Anchorage,Alaska 99507 General Ms.Wendy Walt Office of Coastal Management Division of Policy Development and Planning Pouch AP Juneau,Alaska 99811 TABLE E.11.2:ORIGINAL LIST OF REPORTS AND GROUPS TO WHICH REPORTS WERE/WERE TO BE SENT Report Plan of Study and Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report 1980 Annual Reports Fish Ecology Big Game Birds and Non-Game Mammals Furbearers Plant Ecology Land Use Socioeconomics Cultural Resources Recreation Instream Flow Study Plan Transmission LiRe:Corridor Screening Report Fish and Wildlife Mitigation Policy Feasibility Report 1981 Final Phase I Reports FWB =Fish,Wildlife,and Botanical ALU =Aesthetics,Land Use HA =Historic and Archaeological R =Recreation WQ =Water Quality G =General Group A11 A11 A11 FWB FWB FWB FWB FWB AlU HA HA R WQ,FWB,G A11 FWB A11 A11 TABLE E.ll.3:ORIGINAL LIST OF AGENCIES AND REPORTS RECEIVED - - Alaska Department of Natural Resources Alaska Department of Fish and Game Alaska Department of Environmental Conservation Alaska Department of Community and Regional Affairs Plan of study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report Instream Flow Study Plan 1980 Socioeconomic Annual Report 1980 Cultural Resources Annual Report 1980.Land Use Annual Report 1980 Recreation Annual Report Transmission Line Corridor Screening Report Fish and Wildli fe Mitigation Policy fe~sibHity Report Final Phase I Reports Plan of Study and Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report Instream Flow Study Plan 1980 Fish Ecology Annual Report 1980 Big Game Annual Report 1980 Birds and Non-Game Mammals Annual Report 1980 Furbearers Report 1980 Plant Ecology Report Transmission Line Corridor Screening Report Fish and'Wildlife Mitigation Policy Feasibility Report Final Subtask Reports Plan of Study Plan of Study Revisions Development.Selection Report 1980 Annual:Envirolilmental Summary Report Instream Flow Study Plan 1980 Fish Ecology Annual Report 1980 Big Game Annual Report 1980 Birds and Non-Game Mammals Annual Report 19BOFurbearers Report 1980 Plant Ecology Report Transmission Line Corridor SCreening Report fish and Wildlife MitigaUon Policy feasibility Report Final Subtask Report Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summar.y Report 1980 Socioeconomic Annual Report 1980 Cultural Resources'!Mnua!Report Transmission Line Corriddl),'Screening Report Feasibility Report Final Subta~k Reports TABLE E.l1.3:(Page 2) Division of Policy Development and Planning Office of Coastal Management Mantanuska-Susitna Borough Cook Inlet Region,Inc. U.s.Environmental Protection Agency U.s.Army Corps of Engineers National Marine Fisheries Service Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report Instream Flow Study Report Transmission Line Corridor Screening Report Feasibility Report Final Subtask Reports Plan of Study Plan of Study Revisions. Development Selection Report 1980 Annual Environmental Summary Report 1980 Recreation Annual Report Transmission Line Corridor Screening Report Feasibility Report Final Phase I Reports Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report 1980 Land Use Annual Report Transmission Line Corridor Screening Report Feasibility Report Final Phase I Reports Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report Instream Flow Study Plan Transmission Line Corridor Screening Report Feasibility Report .. 1981 Final Phase I Reports Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report Instream Flow Study Plan Transmission Line Corridor Screening Report Feasibility Report 1981 Final Phase I Reports Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report lnstream Flow Study Report 1980 Fish Ecology Annual Report 1980 Big Game Annual Report 1980 Birds and Non-Game Mammals Annual Report 1980 Furbearer Report 1980 Plant Ecology Transmission Line Corridor Screening Report Fish and Wildlife Mitigation Policy Feasibility Report 1981 Final Phase 1 Reports TABLE E.ll.3:(Page 3) /t;I;IiJ;!IiA U.S.Fish and Wildlife Service National Park Service U.S.Bureau of land Management Plan of Study Plan of Study Revisions Development Selection Report 1980 Annual Environmental Summary Report Instream Flow Study Plan 1980 Fish Ecology Annual Report 1980 Big Game Annual Report 1980 Birds and Non-Game Mammals Annual Report 1980 Furbearer Report 1980 Plant Ecology Report Transmission line Corridor Screening Report Fish and Wildlife Mitigation Policy Feasibility Report 1981 Final Phase I Reports Plan of Study Plan of Study Revisions Development Selection Report Instream Flow Study ~lan 1980 Annual Environmental Summary Report 1980 Socioeconomic Annual Report . 1980 Cultural Resources Annual Report 1980 Recreation Annual Report Transmission Line Corridor Screening Report Feasibility Report 1981 Final Phase I Reports Plan of Study Plan of Study Revisions Development Selection Report Instream Flow Study Report 1980 Annual Environmental Summary Report 1980 land Use Annual Report Transmission line Corridor Screening Report Feasibility Report . 1981 Final Phase 1 Reports TABLE E.l1.4:AGENCY COORDINATION EXPANDED LIST Water Quality and Use Group Mr.Max Brewer * Office of the Director Special Assistant for Alaska U.S.Geological Survey 21B East Street Anchorage,Alaska 99501 Mr.John Cook ** Acting Regional Director Alaska Region National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 Mr.John Kat z Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 Mr.Robert ~y * Director,Alaska Region National Marine Fisheries Service NOAA P.O.Box 1668 Juneau,Alaska 99802 Mr.Ernest W.Mueller * Commissioner Alaska Department of Environmental Conservation Pouch 0 Juneau,Alaska 99801 Colonel Lee Nunn District Engineer Alaska District U.S.Army Corps of Engineers P.O.Box 7002 Anchorage,Alaska 99510 Mr.John Rego Bureau of Land Management Anchorage District Office 4700 East 72nd Avenue Anchorage,Alaska 99507 Mr.Keith Schreiner * Regional Director,Region 7 U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,Alaska 99501 Mr.Ronald O.Skoog * Commissioner State of Alaska Department of Fish &Game Support Building Juneau,Alaska 99801 cc:Mr.Larry Wright NatiQnal Park Service 1011 East Tudor Road Suite 297 Anchorage,Alaska 99503 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Pouch 7-005 Anchorage,Alaska 99510 cc:Mr.Ron Morris Director Anchorage Field Office National Marine Fisheries Service 701 C Street,Box 43 Anchorage,Alaska 99513 cc:Mr.Bob Martin Alaska Department of Environmental Conservation 437 East Street,2nd Floor Anchorage,Alaska 99501 cc:Mr.Lenny Corin U.S.Fish and Wildlife Service Western Alaska Ecological Service 733 West 4th Avenue Anchorage,Alaska 99501 cc:Mr.Thomas Trent State of Alaska Department of fish and Game 2207 Spenard Road Anchorage,Alaska 99502 *Added at the suggestion of the Susitna Hydro Steering Committee. **Added as a result of specific agency request. TABLE E.11.4:(Page 2) Mr.John R.Spencer Regional Administrator Region X U.S.Environmental Protection Agency 1200 Sixth Avenue Seattle,Washington 98101 cc:Ms.Judy Swartz U.S.Environmental Protection Agency Mail Stop 443 Region X EPA 1200 South 6th Avenue Seattle,Washington 98101 Fish,Wildlife,and Botanical Group-Mr.Max Brewer * Office of the Director Special.Assistant for Alaska U.S.Geological Survey 218 East Street Anchorage,Alaska 99501 Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Pouch 10U5 Anchorage,Alaska 99510 Mr.Robert McVey Director,Alaska Region National Marine Fisheries Service NOAA P.O.Box 1668 Juneau.Alaska 99802 Mr.Ernest W.Mueller Commissioner Alaska Department of Environmental Conservation Pouch 0 Juneau,Alaska 99801 Mr.John Rego * Bureau of Land Management Anchorage District Office 4700 East 72nd Avenue Anchorage,Alaska 99507 cc:Mr.Ron Morris Director Anchorage Field Office National Marine Fisheries Service 701 C Street,Box 43 Anchorage,Alaska 99513 cc:Mr.Bob Martin Alaska Department of Environmental Conservation 437 East Street,2nd Floor Anchorage,Alaska 99501 cc:Mr.Robert Bowker U.S.Fish and Wildlife Service Western Alaska Ecological Service 733 West 4th Avenue Anchorage,Alaska 99501 Mr.Thomas Trent State of Alaska Department of Fish and Game 2207 Spenard Road Anchorage,Alaska 99502 Mr.Keith Schreiner Regional Director,Region 7 U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,Alaska 99503 Mr.Ronald O.Skoog cc: Commissioner State of Alaska Department of Fish and Game Support Building Juneau,Alaska 99801 *Added at the suggestion of the Susitna Hydro Steering Committee. TABLE E.l1.4:(Page 3) Mr.John Spencer * Regional Administrator U.S.Environmental Protection Agency 1200 Sixth Avenue Seattle,Washington 98101 cc:Ms.Judy Swartz U.S.Environmental Protection Agency Mail Sto p 443 Region X EPA 1200 Sixth Avenue Seattle,Washington 98101 Historic and Archaeological Group Mr.John Cook Acting Regional Director Alaska Region National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 cc:Mr.Larr y Wr,ight National Park Service 1011 East Tudor Road Suite 297 Anchorage,Alaska 99503 Ms.Lee McAnerney Department of Community and Regional Affairs Pouch B Juneau,Alaska 99811 Mr.John Rego * Bureau of Land Management Anchorage District Office 4700 East 72nd Avenue Anchorage,Alaska 99507 Mr.Robert Sh aw State Historic Preservation Officer Alaska Department of Natural Resources Division of Parks 619 Warehouse Avenue,Suite 210 Anchorage,Alaska 99501 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 Mr.Ronald o.Skoog *cc: Commissioner State of Alaska Department of Fish and Game Support Building Juneau,Alaska 99801 Mr.Lee Wyatt** Planning Director Matanuska-Susitna Borough Box B Palmer,Alaska 99645 Recreation Group Mr.Thomas trent State of Alaska Department of Fish and Game 2207 Spenard Road Anchorage,Alaska 99502 Mr.John Cook Acting Regional Director Alaska Region National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 cc:Mr.Larry Wright National Park Service 1011 East Tudor Road Suite 297 Anchorage,Alaska 99503 *A~ded at the suggestion of the Susitna Hydro Steering Committee. **Added as a result of specific agency request. TABLE E.ll.4:(Page 4) Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 Mr.Robert McVey * Director,Alaska Region National Marine Fisheries Service NOAA P.O.Box 1668 Juneau,Alaska 99802 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 cc:Mr.Ron Morris Director Anchorage Field Office National Marine Fisheries Service ., 701 C Street,Box 43 Anchorage,Alaska 99513 ~, - Mr.Keith Schreiner * Regional Director,Region 7 U.S.Fish and Wildlife Service 1011 East Tudor Ro ad Anchorage,Alaska 99503 Mr.Ronald O.Skoog *cc: Commissioner State of Alaska Department of Fish and Game Support Building Juneau,Alaska 99801 Mr.Lee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer,Alaska 99645 Mr.Thomas Trent State of Alaska Department of Fish and Game 2207 Spenard Road Anchorage,Alaska 99502. Aesthetics and Land Use Group ~, Mr.John Cook ** Acting Regional Director Alaska Region National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 Mr.Roy Huhndorf President Cook Inlet Region,Incorporated P.O.Drawer 4N AQchorage,Alaska 99509 Mr.John Kat z Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 Mr.John Rego Bureau of Land Management Anchorage District Office 4700 East 72nd Avenue Anchorage,Alaska 99507 cc:Mr.Larry Wright National Park Service 1011 East Tudor Road Suite 297 Anchorage,Alaska 99503 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7...005 Anchorage,Alaska 99510 *Added at the suggestion of the Susitna Hydro Steering Committee. **Added as the result of specific agency request. TABLE E.ll.4:(Page 5) Mr.Keith Schreiner * Regional Director,Region 7 U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,Alaska 99503 Mr.Ronald O.Skoog *cc: Commissioner State of Alaska Department of Fish and Game Support Building Juneau,Alaska 99801 Mr.Lee Wyatt** Planning Director Matanuska-Susitna Borough Box B Palmer,Alaska 99645 Mr.Thomas Trent State of Alaska Department of Fish and Game 2207 Spenard Road Anchorage,Alaska 99502 Socioeconomic Group* Director of~nning Fairbanks North Star Borough 520 5th Avenue P.O.Box 1267 Fairbanks,Alaska 99701 Mr.Roy Huhndor f President Cook Inlet Region,Incorporated P.O.Drawer 4N Anchorage,Alaska 99509 Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 cc:Mr.Max Dolchak Executive Director Cook Inlet Native Association 670 Firewood Lane Anchorage,Alaska 99502 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Resources Pouch 7-005 Anchorage,Alaska 99510 Ms.Lee McAnerney Department of Community and Regional Affairs Pouch B Juneau,Alaska 99811 Mr.Michael Meehan Director,Planning Department Municipality of Anchorage Pouch 6-650 Anchorage,Alaska 99502 Mr.Ronald O.Skoog *cc: Commissioner State of Alaska Department of Fish and Game Support Building Juneau,Alaska 99801 Mr.Herb Smelcer,President General Manager AHTNA Corporation Drawer G Copper Center,Alaska 99573 Mr.Thomas Trent State of Alaska Department of Fish and Game 2207 Spenard Road Anchorage,Alaska 99502 *Added at the suggestion of the Susitna Hydro Steering Committee. **Added as a result of specific agency request. TABLE E.l!.4:(Page 6) Mr.lee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer,Alaska 99645 Geological and.Soils Group * Mr.Max Brewer Office of the Director Special Assistant for Alaska U.S.Geological Survey 218 East Street Anchorage,Alaska 99501 Mr.John Kat z Alaska Department of Natural Resources Pouch M Juneau,Alaska 99811 General Mr.David Haas State-Federal Assistance Coordinator State of Alaska Office of the Governor Division of Policy Development and Planning Pouch AW Juneau,Alaska 99811 Ms.Wendy Walt Office of COastal Management Division of Policy Development and Planning Pouch AP Juneau,Alaska 99811 cc:Mr.Alan Carson Division of Natural Resources Alaska Department of Natural Pouch 7-005 Anchorage,Alaska 99510 ,~ *Added at the suggestion of the Susitna Hydro Steering Committee. TABLE E.ll.5:EXPANDED LIST OF REPORTS AND GROUPS TO WHICH REPORTS WERE/WERE TO BE SENT REPORT GROUP* R,ALU R,ALU,SE R,ALU,GS R,ALU,SE HA,R,ALU,SE,GS HA,R,ALU,SE,GS Instream Flo~Study Plan Dra ft Fishery Mitigation Plan Draft Wildlife Mitigation Plan Final Phase I Reports: (a)Fish Ecology (b)Wildlife Ecology (c)Plant Ecology (d)Birds and Non-Game Mammals (e)Furbearers (0 Land Use (g)Socioeconomics (h)Cultural Resources (i)Recreation Land Status Report Interim Report on Seismic Studies Final Report on Seismic Studies Geotechnical Exploration Report on 1980 Studies Geotechnical Exploration Report on 1981 Studies Water Quality Report Water Use Report River Morphology Sociocultural Report Environmental Evaluation of Access Plans Engineering Evaluation of Access Plans R,ALU WQ,FWB,R,ALU WQ,FWB,R,ALU WQ,FWB,R WQ,FWB,R FWB,ALU FWB,R FWB,R,SE ALL FWB,R,ALU,SE,G HA,SE R R,ALU,SE,GS GS GS GS GS WQ,FWB, WQ,FWB, WQ,FWB, FWB,HA, WQ,FWB, WQ,FWB, *ALU FWB HA WQ R SE GS G =Aesthetics,Land Use =Fish,Wildlife,and Botanical=Historic,Archaeological =Water Quality =Recreat ion =Socioeconomic=Geology and Soils =General Note:These reports and groups ~ere added to those listed in Table 1.2. Groups refer to those listed in Table 1.4. DOCUMENT TABLE E.l1.6:REPORTS,DATE SENT,AND PURPOSE PRIOR TO 03/15/82 03/15/82 04/01/82 04/15/82 04/30/82 PURPOSE* Plan of Study X Plan of Study -Revision 1 X 1980 Summary Environmental Report X 1980 Annual Environmental Reports: (a)Fish Ecology X (b)Plant Ecology X (c)Big Game,Birds,and Non-Game X Mammals,Furbearers (d)Land Use X (e)Socioeconomics X (f)Cultural Resources X Transmission Line Corridor Screening ~~t X Development Selection Report X Initial Fish and Wildlife Mitigation Policy X (Revised Mitigation Policy) Instream Flow Study Feasibility Report Draft Fishery Mitigation Plan Draft Wildlife Mitigation Plan Phase I Environmental Reports: (a)Fish Ecology -ADF&G (b)Wildlife Ecology -ADF&G (c)Plant Ecology (d)Bird and Non-Game Mammals (e)Furbearers (f)Land Use (g)Socioeconomics (h)Cultural Resources (i)Recreation· Land Status Report Interim Report on Seismic Studies Final Report on Seismic Studies Geotechnical Exploration Report on 1980 Studies Geotechnical Exploration Report 1981 Studies Water Quality Report Water Use Report River Morphology Report Sociocultural Report Environmental Evaluation of Access Plans Access Route Selection Report *FC :Formal Comments Requested I :Provided for Information Only X X X X X X X X X X X X X X X X X X X X X X X X X FC FC I I I I I I I FC FC FC FC FC FC FC FC I I I I I I I I FC I I I I I I I I I I I TABLE E.11.7:AGENCIES INVITED AND THOSE WHICH DECLINED TO BE ON THE FISH AND WILDLIFE MITIGATION REVIEW GROUP State Agencies Status Alaska Department of Fish and Game Alaska Department of Natural Resources Federal Agencies U.S.fish and Wildlife Service National Marine fisheries Service U.S.Bureau of Land Management Environmental Protection Agency U.S.Geological Survey U.S.Army Corps of Engineers Agreed Agreed Agreed Agreed Agreed Agreed Declined Declined TABLE E.11.8:MEMBERS OF THE SUSITNA HYDROELECTRIC PROJECT STEERING CGMMITTEE - State Agencies Alaska Department of Fish and Game Alaska Department of Natural Resources Alaska Department of Commerce Alaska Department of Environmental Conservation Other Federal Agencies U.S.Fish and Wildlife Service U.S.Geology Survey National Park Service National Marine Fisheries Service U.S.Bureau of Land Management Environmental Protection Agency Heritage Conservation and Recreation Service ~ I Arctic Environmental Information and Data Denter Note:U.S.Army Corps of Engineers,Alaska Division of Policy Development and Planning and Matanuska-Susitna Borough were invited but declined to sit on the Steering Committee. TABLE E.l1.9:DATES AND PURPOSE OF STEERING COMMITTEE MEETINGS WITH APA AND/OR ITS CONSULTANTS DATE PURPOSE June 12,1980 Objective of Committee and Introduction to Project Ju Iy 17,1980 Federa I Energy Regu latory Commiss ion and State License Process,Instream Flow StudIes November 5,1980 Evaluation of Alternatives to Susitna Apri I 13,1981 Alternatives,Access Road Evaluation,and Comments on Envlronmenta I Studies October 20,1981 Access Road Eva luation December 2,1981 Explanation of Agency Comments Requests from APA January 20,1982 Environmental Studies and Concerns, FIsheries Mitigation June 14,1982 Instream Flow Studies,Access Road Evaluation,Formal ization of Steering Committee role November 4,1982 Reorganization of Steering CommIttee, Status of AEIDC Work and Discussion of Land Use and Recreation TABLE E.ll.10:OBJECTIVES OF THESUSITNA HYDROELECTRIC ENVIRONMENTAL WORKSHOP SUS ITNA HYDROELECTR IC PROJECT FERC License Application Exhibit E Presentation and Discussion Anchorage,Alaska Hoi i day Inn November 29 -December 2,1982 Objectives 1.Update federal,state,and local agencies regarding-significant changes in project features since the Feas Ibi II ty Report was pub Ii shed In March 1982. 2.Use the presentations and discussions as an interactive process whereby federal,state,and local agency review of the draft Exhibit E can be faci I itated. 3.Develop a mechanism for continued interaction as the finalized Exhibit E Is prepared for submission to FERC. TABLE E.ll.11:AGENDA OF THE SUSITNA HYDROELECTRIC PROJECT ENV1RONMENTAL WORKSHOP Monday,November 29 1:00 P.M. IntroductIon Project Operational Description Watana Dam Devil Canyon Dam Access TransmIssion Schedule for Preparation of Exhibit E Group Definition Tuesday,November 30 9:00 A.M. Group 1 -Water Use and Quality and FIshery Resources Group 2 -WI Id life and Botan i ca I Resources Group 3 -Socioeconomic/Land Use Group.4 -Cu Itura I Resources Wednesday,December 1 9:00 A.M. Group 1 -Water Use and Quality and Fishery Resources Group 2 -WIldlife andBotanrc~1 Resources Group 3 -Recreation and AesthetIcs Thursday,December 2 9:00 A.M. Group 1 -Water Use and Quality and Fishery Resources Group 2 -WildlIfe and Bot~njcal Resources Name Michael p.Storonsky Philip Hoover Thomas Lavender Tony Burgess Michael Grubb Charlotte Thomas Steve Fancy Martha Raynolds Robert Sener Dave Tremont Ro land Shanks Priscilla Lukens Michele Urban Tom Armlnskl Leonard Cor In Larry Moulton Jean Baldridge Keith Qulntavell Robert Mohn George Gleason John Blzer • Jack Robinson Randy Fa I rbanks Gary lawley George S.Sm Ith E.James Dixon B.Agnes Brown Carole A.Ellerbee Robert M.Erickson Tim Smith Richard Fleming Bob Madison Bob Lamke Bob Martin Don McKay George Cunningham Randy Cowart AI Carson Paul Janke Gary Prokosch Mary Lu Har Ie Robin HII I Peter Rogers Steve Zrake Jan Ha II Gary Stackhouse Brad Smith BII I lawrence Floyd Sharrock Bruce Bedard Ann Rappoport Bob Everett Er Ic Myers John Rego Lee Adler Bill Wilson Chris Godfrey Ted Rockwe II Larry M.Wright Kevin R.Young John W.Hayden Wayne Dyok TABLE E.ll.12:LIST OF ATTENDEES SUSITNA HYDROELECTRIC PROJECT WORKSHOP Hoi Iday Inn,Anchorage,AK Monday,November 29,1982 Organization Acres Acres Acres Acres Acres Alaska Power Authority LGL Alaska LGL Alaska LGL Alaska Dept.Community Regional Affairs Cook Inlet Region,Inc. Acres HarzalEbasco Alaska Power Authority USFWS Woodward-Clyde Woodward-C I yde DNR -DLWM Alaska Power Authority Alaska Power Authority Harza/Ebasco Harza/Ebasco Harza/Ebasco Harza/Ebasco University of AK Museum UnIversity of AK Museum Tyonek Native Corporation Tyonek Native Corporation EDAW,Inc. DNR-Parks (History and Archaeology) Alaska Power Authority USGS-WRD USGS-WRD ADEC ADF&G ADF&G ADNR~&D ADNR ADNR ANDR-Water ANDR-Water Management Frank Orth &Associates Frank Orth &Associates ADEC USFWS USFWS NMFS U.S.EPA NPS Alaska Power Authority USFWS-WAES ESSA Ltd. NAEC BLM AHTNA,Inc. AEIDC COE USCE Reg.Fnctlon NPS Acres Acres Acres Telephone 276-4888 II II II 716-853-7525 276-0001 479-2669 274-5714 274-5714 264-2206 274-8638 276-4888 277-1561 276-0001 271-4575 276-2335 276-2335 276-2653 276-0001 "277-1561 II ""474-7818 "272-4548 "274-3036 264-2139 276-0001 271-4138 "274-2533 267-2284 II 276-2653 276-2653 "276-2653 "206-455-3507 "274-2533 263-3403 263-3475 271-5006 271-5083 271-4216 276-0001 271-4575 274-5714 276-4244 267-1273 822-3476 279-4523 552-4942 II 271-4236 716-853-7525 907-276-4888 907-276-4888 ..... - ,- ALASKA POWER AUTHORITY PUBLIC DIRECT AGENCY CONTACT-PARTICIPATION THROUGH PROGRAM AGENCY CONTACT CONSULTANTS ~ I -ACTION RESPONSE FORMAL INFORMAL r--AGENCY REVIEW AGENCY REVIEW -NEWSLETTERS WRITTEN SUSITNA HYDRO CORRESPONDENCE STEERING r-- WITH AGENCIES COMMITTEE IDENTIFIED IN FERC REGULATIONS r--PUBLIC MEETINGS ENVIRONMENTAL WORKSHOP - FISH AND WILDLIFE MITIGATION -WORKSHOPS REVIEW GROUP WRITTEN CORRESPONDENCE ON DRAFT EXHIBIT E ORGANIZATION OF AGENCY CONSULTATION PROGRAM FIGURE E.I!.I 1 I 1 J ])j ])I B I DRAFT LICENSE STUDY PHASES DEVELOPMENT OF PLAN OF STUDY DATA COLLECTION IMPACT PREDICTION MITIGATION PLANNING PROJECT PLANNING FEASIBILITY REPORT AND ASSOCIATED SUPPORT DOCUMENTS ADDITIONAL DATA COLLECTION IMPACT PREDICTION MITIGATION PLANNING FINAL LICENSE APPLl- APPLICATION ICATION • I •I I DRAFT LICENSE APPLICATION AND WORKSHOPI. I I• • REVISED ACCESS PLANS • lit LICENSE APPLICATION DECISION • I I • I FEASIBILITYIREPORT I I• w DOWNSTREAM FLOW RELEASE • I I • I DEVELOPMENT SELECTION I I I• w I I I I PLAN I OF STUDY I I I I ',I PROCEDURE ACCESS FISH I FEASIBILITY WILDLIFE REVISED I LICENSE I MANUALS'PLAN AND SUPPORT MODEL DOWNSTREAM APPLICATION I WILDLIFE I DOCUMENTS FLOW I I' I MITIGATION RELEASE I I OPTIONS I I I I I I I I I I I I I I '980 I '981 I 1982 I '983 I MAIN REVIEW ITEMS SCHEDULE AGENCY CONSULTATION REVIEW PROCESS FIGURE E.II.2 APPENDIX EllA CORRESPONDENCE RELATING TO ORGANIZATION OF CONSULTATION PROGRAM .... ..... - -- APPENDIX 11.A ORGANIZATION OF CONSULTATION PROGRAM The Alaska Power Authority established a number of committees and interagency groups to serve as a means of consulting with federal and state agencies. This included the Susitna Hydro Steering Committee and the Fish and Wildlife Mitigation Review Group.In addition,reports concerning each of the major subject divisions (water quality,recreation,wildlife,etc.)were circulated to the appropriate agencies responsible for these resources . This appendix contains correspondence concerning the organization and estab- lishment of the Susitna Hydro Steering Committee and correspondence relating to the various agencies groups.The first set of letters address the Susitna Hydro Steering Committee;the second the agency coordination program.Due to the importance of mitigation as a separate effort,correspondence concerning this subject is in Appendix 11.E.Correspondence concerning comments on individual reports is in Appendix 11.C and G. - -- ALASKA POWER AUTHORITY June 3,1980 The Honorable Lee McAnerney Commissioner Department of Community and Regional Affairs Pouch B Juneau s Alaska 99311 Dear Commissioner McAnerney: The Alaska Power Authority through its consultant,Acres Aw~r1can Incorporated s is in the early stages of a 30-month feasibility study of the proposed Susitna Hydroelectric Project.Because of the magnitude of this studys effective interagency coordination will be best accomplished through formation of a Susitna Hydroelectric Steering Committee.The function of this cOlmlittee---YTould be to provide _coordinated exchanges of information beo'/een the Alaska Power Authority and interested resource management agencies. Through this exchange~the ,concerns of all agencies involved~would be identified early and hopefully prevent unnecessary delays in the progress of the feasi- bility studYt application for the Federal Energy Regulatory Commission license to construct.and Environmental Impact Statement review. As proposed s the Steering Committee would be composed of representatives of resource agencies with responsibilities pertaining to the Susitna Hydro- electric Feasibility Studies and/or the project's environmental consequences. We therefore invite your agency's participation. The committee would provide for 1nteragency coordination through joint revievi of project related materials and development of more informed and uniform positions representing all resource interests.We believe this will provide a more efficient process of information exchange. Proposed objectives for this comm1ttee are to: 1.Revie~and comment on study approaches throughout each phase of the planning process; 2.Insure that the biological and related environmental studiess their timing,and technical adequacy are planned.implemented s and conducted to provide the quantitative and qualitative data necessary to: (a)assess the potential impacts to fish and wildlife resources,and (b)provide the basis form1tigat1on and compensation of resource losses which will result from the project; Corrrniss ioner lee i-kJ\ner.-·"Y June 3,198(\"'..J Page T\'1O 3.Provide a rorum for continued project revi eVI of all aspects of the studies.for a timely exchange of information,and for recommendation of study redirection,should the accomplishment of specific objectives be in jeopardy; 4.Monitor compliance of the studies with all state and federal laws, regulations.Executives Orders.and mandates as they apply to fish and wildlife resources;and 5.Provide unified agency COTImlents from the committee to the Power Authority. Should your agency elect to participate in the cormnittee,we recol11Tlend that your representative have a technical background enabling him to comment on the adequacy and approach of ongoing and future feasibility studies,and be able to speak knowledgeably on the policies and procedures of your agency with respect to the review of the Federal Energy Regulatory Commission license ap~licat1on for the project and the subsequent Environmental Statement (ES). The first Susitna Hydroelectric Steering Committee m~et1ng will be held at the Alaska Power Authority.333 West 4th Avenue,Suite 31,Anchorage, A1aska on June 12th at 9:00 AM.Attached is a sheet with a description of the agenda for this first meeting.Your attendance is encouraged • • Sincerely, Eric P.Yould Executive Director Attachrnent: as noted ~, Preceding Letter Sent To: Ms.Lee McAnerney Department of Community and Regional Affairs Pouch B Juneau,AK 99811 Mr.Harry Hulsing,Chief U.S.Geological Survey Water Resources Division 218 E Street Anchorage,AK 99501 Colonel Lee Nunn U.S.Army Corps of Engineers P.O.Box 708 Anchorage,AK 99510 Mr.Bob Bowker U.S.Fish and Wildlife Service 733 West 4th Avenue Anchorage,AK 99501 I~r.John Rego U.S.Bureau of Land Management 4700 East 72ndAvenue Anchorage,AK 99507 Mr.Robert E.LeResche Commission~r Alaska Department of Natural Resources Pouch M Juneau,AK 99811 Mr.Frances A.Ulmer,Director Division of Policy Development and Planning Office of the Governor Pouch AD Juneau,AK 99811 Mr.Ronald O.Skoog Commissioner Alaska Deparunent of Fish and Game Juneau,AK 99801 AILASliA PO\Vll~R AUTHORITY SUSITNA HYDRO STEERING COMMITTEE Bob Lamke U.S.Geological Survey \·/ater Resources 733 W.4th Avenue,Suite 400 Anchorage,Alaska 99501 271-4138 John Rego Bureau of Land Management Anchorage District Office 4700 E.72nd Avenue Anchorage,Alaska 99502 344-9661 Brad Smith National Marine Fisheries Studies 701 "C"Street,Box 43 Anchorage,Alaska 99513 271-5006 William J.Wilson Arctic Environmental Information & Data Center,(U of A) 707 A Street Anchorage,Alaska 99501 279-4523 Al Carson State of Alaska Department of Natural Resources 323 E.4th Avenue Anchorage,Alaska 99501 279-5577 Tom Tren.t Alaska Department of Fish and Game 2207 Spenard Road Anchorage,Alaska 99503 274-7583 Larry Wright Heritage Conservation and Recreation Service 1011 E.Tudor Road,Suite 297 Anchorage,Alaska 99503 276-1666 Lenny Corin U.S.Fish and vJild1ife Service 733 W.4th Avenue,Suite 101 Anchorage,Alaska 99501 271-4575 Gary Stackhouse U.S.-Fish &Wildlife Service 1011 E.Tudor Road Anchorage,Alaska 99501 276-3800 Bob t~arti n Department of Environmental Conservation 437 E Street Anchorage,Alaska 99501 274-2533 Mr.Bill Lawrence Anchorage Operations Office Environmental Protection Agency 701 C Street Anchorage,Alaska 99513 271-5083 Judy Schwarz Environmental Evaluation Branch Mail Stop 443 Region X,EPA 1200 6th Avenue Seattle,Washington 98101 (206)442-1285 TII'IE : Dfl1E: PLt\C [ : !\GEND/\: SUSIHU\HYDfW STEC!{I:iC_..__,_"._0- 9:00 Ai·l June 12.1980 A1as ka PO\'II;]",~uthori ty 333 West 4th Avenue,Suite 31 Anchorage.AlaskJ 99501 !':[~,'j"I ;.;(~ I~ 3. .~. s. ""v. A discussion and outlining of the purrose one!()l)j~ctiv(~:.of the Susitna"'Hydro Steering Committc:e. /\review by Acres Aiilerici:ln of the procedurz,l uSPeGts of the FEf\C license application,the ES r~yiew processes,Jnd their pcrspccti~es on the procedural mileposts for this project. A discussion of the proposed FERC license appliCJtion and ES review process by the Steering Committl:c and ull assessment of the ugencies v;el'ls and maildates to rcvievi and COi71ment u;)on the proposed rroject. i\rcvievi of the S..l1sitna Hydro feilsibility tllsks by «res t.r:1(~r-ican with'discussion of FERC's possible requirements for study,technical standards,and land or env1r'onmcntal sturly sub,iects Villich rnu::.tb(~ cr:lpna S ,zed. A discussion by the Steering Committee of the cross study task or interdisciplinary J.spects of the Susitna i!ydro fCllsibility 'Itudics. Steering Committee discussion of (l proposed iJ~jr:i1d(\fOt-thl.?July meeting involving representatives of FERC. -,._'-'- v..s r-·u ::; --j'c<~J t.I S FJA"~ Q.-liU\::",C- "...,'- --\.-.,,',.j P!1011r:.(')(i7)277·761,1 (007)276·27 i 5 .... July 7,]gel! Mr.Ronald Morris National r1arine Fishe:-y Service 701 "["Street Anchorilg-,t,laska 99513 The Alaska Pm.;er ,"IuUlOrity,(lcting e,n beh"lf OJ·the rc:sOUi'ce m;\ilaJe~~ent agencies,·,.;ovld like to inform yOiJ of the second ~usitn<3 Hydr'o Steering Committee meeting.i\t the request of the vilrious ilgencics, .....e hi!.ve n~ade anange,:1f:nts for I'epresentatives of the Federal Energy F<e 9 u1a tor y Ca l1~m iss ion tab e pre sen tat the me e ti ngin crd e r to d n S.../Q )- tee hni ca I que s t ion s.The sub j ec t 0 f the fir s t day 0 f t his t ,10 day session will consist of a discussion of the general technical aspects of .the FERC and s ta te 1 i cens i ng process whereas the second di\j "'Ii 11 spec ifi Cd 11 y address the Susitna fisheries and in-stream flow studies crograms.,....,. In addition to the above topics,an election of a committee chairmiln will take place (please be thinking of prospective candidates for nomination), and the guidelines for the committee's organization will be established. i.,. ,.,:'.' The first days session of.the second .susitna Hydro Steering Committee meeting ~il1 be held at the·AC~Lucy Cuddy Ce~ter on July 17th at B~OO a.m. The secorid day's session ~111tie held at the Federill Building,Room C-105 on July 18th at 8:30 a.m.~.Atti2h~d is-a sheet with a description of the meeti.ng.~~enda.Your parti~i~ition ~s ~ncouraged. Sincerely, L?\\~Ll Eric r.Yould ' Executive Director SUSITNt,HYOfW STEERP;C;CmlllITTf:T 1'1EETING 1s t 0(1 v Dote: Time: Place: Da:e: Time: Place: 1st Day Topics July 17,19nC 8:00 c..I11. ACe Lucy Cuddy Center .July 18,lCJnO n:10 a.m. Federill Guilrlina,Room r-10~ P,:00 c1.m.-9:30 a.111 • o Election of iI cOlllmittee chait'man D Discussion of the committee's organization o Anv ntheritems of concern 9:30 a.m.-5:00 p.m. o General technical overview of FERC licensing process D Discussion of general technical license requirements for hyroelectric projects (both FERC and State) a Discussion of Susitna specific technical license requirements (both FERC ilnd State) 2nd [jay Topics 8:30 a,m.-5:00 p.m. e Potential changes in Susitna i}lver hydrology due to hydroe 1ectd C development o Details of hydrology -water quality monitoring pro~ram a Details of the ADf&G fisheries progrilm o Development of fisheries impact predictions and mitig~tion p 1an, o Hodifications incoqJol-aced into the study pl'OQrillll ln order to i\ceo mo date the i n- s t r C il rn f1 0\'1 stu cI i e s II Oi 5 eus si on of deta i1s on i Il-S trearn f1 01'1 5 t\10 i es ..... SUSITNA HYDRO STEERING COMMITTEE MEETING July 17th &18th,1980 PERSONS NOTIFIED OF THE MEETING .... ",.... i A1 Carson Bob Lamke Bill Hilson Bi 11 ('lel ch Pat Beckley John Rego 80b Bowker Rickki Fowler Gary Stackhouse Lee l'!yatt Jim Sweeney Heinz Noonan Dave Sturdevant Dick Eakins j·iu rray Wa 15 h Larry Kimball Department of Natural Resources U.S.G.S.-W.R.D. AEIDC-University of Alaska Heritage Conservation &Rec. BLM BLM U.S.Fish &Hildlife tnvironmental Conservation U.S.Fish &Wildlife Serviu t1a t-Su Borough Environmental Protection Agency (US) Energy &Pow~r Development Environmental Conservation Div.of Economic Enterprise (send twik via 277-1936~ Otfice of Coastal Management CQIll.lli.&R~g.Affairs (Div.of Comm. P lannl n9) 279-5577 271-4138 279-4523 277-1666 344-9661 1344-9661 271-4575 27lf-5527 276-3800 745-4801 271-5083 276-0508 465-2636 465-2018 465-3540 279.:.863b ~).:-0 >';'r<::-// "'-----,L------;- /),5-'f (~':~"'::/':"/(','1 ,J ~<,"~'"."'~,;" Ct/o,/C/'I ;~_:~'~-,:.1,',::.' A r<:,..fl·c.i-;:O)-\V(,.,;,;,I'fA~'--i-;.._f .I..,.,p.'t>~..r,~"~i ;]:J......Y'~;.... c-••,Jc~(u.1 /H ) B,II i...J">~,". c£.,.··<1(t.',,~,) / _.-.--------- /'.//..;/;-,';.y/;y.~,-_....(~ '/;~"~':'''>'''.~~''~~......' '7',,".....<C''1 (":>')cu •~\~-..,Yo ~I i+"",:...f'b -~r ....".. \1 D.»..pL [h~~~r~Do-LA.Sketsuo..l'\t '16S"'-26>Jl:. L~cm..~ /7.:.h h..\Fo w ltA.:2.7<.'/-Sf a 7(SO~-thce~n.lI,.l J2."iUT\<\16 f H'(4) Puu.c..h 0 StANWJ../At qC;gll -ivlCI<~-&d.i .---c·~ 3"3 ~IAn~~51,/(.:+1\, ;.p>~~:r4 ~-r I r;~,"~'k 3~3 C4~~'Itt. ~Y\C.)~~.qq 5'"0 1 ..·f •," ""','_.f .\.\" "' ,~'.:\r•._.,.·w'..c. B~(M(<>5 cJj"<!#Jmd.o-:.wI!'AIT ;9N C /;O;"'cj !JrP 7:)IS 7/-,c.r 0 rr=I c ~ -s'7a-e>E '72 N /Aile ' ;Jhe J;AI(7)~(:)"2.. \ i Johl\J 1<e.~ 34Y-1,,"~j'c..(P "-! \-\l\\~~;~N.\\\l'f\II"41 ~';,\...'i(l ,\<;. "10 \L ~-\--G 0 "l.\.3- ~<-At r:\<ts\~ c:;.a.",\C t b~~V ~'T,-\ -\(,6.,...~~Q\t.,~-, Z 1-\'-5006 - -, J.DN,.}]).G.-t WfUS I'JC ~, 1ft u::n::;:c,."b1Ll!cTll\t.. L La CZ9..'1",(73,q NIe :$j)Il.;)/,.,)C. .sV/Ttr qOD IYlFill'f AI C,tlLi 'Snt;;;.£Tf ~,)Fr=,q'-TJ Ny GI6j ';3 -?S)S' -//1'7/c;u .:..,,,'. /c",i l'L ~L lA..C .\,""\ '.,:..~'---"'-~"~;'';.-., 1 ! ;... 4br--LC:.3 (, (7/~)853-75.,1::) DffiJ'L .&LWtL,XM-l l)\;'Ced~ J,j~~(J0 tf~C-t--h JI P'\LANo/TIAN L orqV1 &?r;{oY 7"£-5 US FpjS ~f·"J l "./!../',",,-.'..' A.C;2 GSA..fYJ CU..1 (A IV /',.j1 r:- e·erA.)or C£/:J~Y7(-,('"Y.> :LOJ../s7fp-lfO'l.CC' J-JJ.L-37b -)9D5 J..7C-Sos,/ ;;70 -38CO (,f'j)!c<5.)--i 5 1/3 --",1/Id.f'-r -If 2 'I"T ~..~.."-/./ ~70-4g88 7S 2--t9-b'1 - ".. g'.K.f\\)51\\\Tl-l AOlii.:c~·T ~AW :;:./q.~/ ·/1 '1'~/"1/).../. "~r--'(~ /1,-:',) '-~-,.~/t·_~j r---/~~.."(.~ t '.-.~ Nt-"\FS Itf'A ,'L.~~~.~..}'-1/ ! -".,,./....)<;./"·f, rh~.~L Jar.1es SVleeney,01 rector U.S.Environoental Protection ,~gency Room E535,Federal Building 701 "C"Street Anchorage.Alaska .99501 Dear f-1r.Sl;leeny: Ju1y 1980 Thank you for your letter regardinl)the Susitna Hydro Steering Committee f:leeting of July 17 and 18.I am sorry to hear you l,'lere unable to attend as it \'iiiS a very informative m~et1n!J.The Steering Committee has,as a result of the meeting.evolved into an organization independent of the Power Authority and acting in a review and advisory capacity to the Power Authority.It is now run \'Jnolly by the various State and Federal agencies.1\.1 Carson of the Alaska repart~1ent of Natural Resources has taken the responsibility of chairman for the cO~Jittee and Ton Trent of the Alaska Department of Fish ~hd Game is ilct-ing as his assistant.I \,,111 see to it that your agency is retained on the f,Jailing list for the committee.Unfortunately.no meeting minutes were taken although a tape recording is avatlableat the Power Authority. I appreciate your continued interest in the cosmittee and encourage your participation at future meetings. Sincerely, Eric P.Youl d Executive DirGctor - ..... ,(ALASKA POWER AUTHORITY January 2,1981 Robert E.leResche.Commiss1oner Alista Departmen't of Natural Resources P.&Jch'M (Mail Stop 1000) Juneau.Alaska 99811 Dear Commissioner leResche: .';,:,j:,'{our organ1zat100 has been cooperating extensively with the Power Author1ty inassess1ng:tha potential effects of hydroelectric development of the Upper Su- s1tna River;Bas1n~',$everal-d1fferent vehicles have been llsed;meetings.corres~ poi\dence,'8.~Su·s1tna Hydroelectric Project Steering COOiTIittee activities.We· feel that the results reflect close consultation and coordination between our or- ganizations. As the study has progressed,more and more items requiring consuHation have emerged.and the future wlll require a stl1lhfgherlevel of involvement.This anticipated level of activity.plus the fact that the Federal Energy Regulatory Ccmn1ss1on (FERC)and the Fish and Wildlife Coordination Act require documentation of such consultations.suggests 1t 1snow appropriate to be more formal in our ex- changes.Accordingly.we advance this suggested procedure to you for your concur- rence and/or suggestions formodiffcat1on." ~, In general.~e propose a two step process.The first step will consist of consultation ';11th the Susitna Hydroelectric Project Steering CoomHtee.'That body \Ifill perfonn evaluations and structure recoomendations.The Power Authority will consider these recommendations and formulate a P9sit1on.Upon completion af these actions,the results w~ll be processed through your agency for formal con- currence. This represents a slight expansion of the original concept under which the Steering Committee was structured;the Committee was to act primarily as an ad- visory bOl-'to the study team while secondarlly facilitating agency involvement in the study effort.Member agencies were to be represented by senior staffers of skills appropriate to the matters under consideration.This was considered to be advantageous as it would facilitate responsiveness by virtue of being relatively independent of procedural 1lI1Pediments •whl1e still reflecting to a substantial de- gree the agency viewpoint. This proposal hopefully preserves those advantages wfthin an expanded role by permitting attainment of interagency concensus with a relatively low level of 1n- put and a high degree of flexibility.It also pennHs the various agencies to tal10r thefr participation to the specific needs.Finally,the second step of re- ferral of Steering Committee deliberations for formal agency concurrence meets regu- latory and statutory requirements. JanUi.1ry 2,1981 Frances A.Ulmer.Director Offfce of the Governor Ofvbionof Policy Development and Planning vouch AD (Hail Stop 01~4) Juneau,.Alaska 99811 ~Ilr Fran: Tt~Power Authority is sttidying and assessing the potential effects of hydro- electric ci.evel0pl:lllmtof the Upppr Sus1tni1 River Bas1n.Accompl1shment of that tas~necessitat~sconsulta~1onand coordination with various Federal,State and 10- cal organ,zations.including yours. As'the study has progr~ssed,more and more items requiring consultation have emElr-ged.and the future ",111 ~uirea still higher level of involvement.Tbis am:1c1pated l'evel of activity.Plus the fact that tho Federal Energy Re-qulatory Comfssion (FERC)and the F'hh anti Wi1dlHe Coordination Act require documentation of suchconsultat1oos ,suggestsft is now appropriate to establiSh a fonna.l P7Q- cedure for our contacts.Accordingly we advance the folimoting plan to you for your concurrence and/or ~uqgestlons for modification. In general.we prop~se a two ~tep process.The first step \~11 consist af consultation w1tnthesusHna Hydtbeicctt1c Project Staedng Comil1ttee.That body will perform evalbaHonsand Stnidur~recoomendatfons.The Power Author1t:Y will consider these recommendations and formUlate a position.Upon completion nf these act f ons 1 the results ~111 be'prer.Msed through the nppropri ate organf zatf OM for forma 1 concurrence~ I request yO"ur ~;tten conr.urN!nce l11th this proposal,or.if you have other thoughts on tha m.ntter •.~e are a,xlol.,IS to explore them with you . .-'.. \(Il/.l",-----''-~-.)""t\ Er1c P.'(auld ' Executive Director cc:Bill Welch.U.S.HeRS Larry Wright,O.S.,BCRS Jim Thomson.U.S.H~Rs, Sent to: Alaska Department of Community and Regional Affairs AlaskaDe~artment of Co~nerce &Economic Development Office of the Governor,Division of Policy Development and Planning Matanuska-Susitna Borough Environmental Protection ~gency,Region 10 Alaska District,Corps of Engineers u.S.Geological SurVey Atta,cnme nt #2 CONCUR: DW RAM EPY Attachment #3 IN REPL Y REFER TO; United States Department of the Interior FISH AND WILDLlI'E SLRV1Cl: Western Alaska Ecological Services 733 W.4th Avenue,Suite 101 Anchorage,Alaska 99501 (907)271-4575 flECEIVED AUISKA POWER AUTHORI~ Eric P.Yould Executive Director Alaska Power Authority 333 W.4th,Suite 31 Anchorage,Alaska 99501 Dear Me Yould: ..1€t.If The U.S.Fish and Wildlife Service (FWS)has received your letter of 2 January 1981 proposing that the agencies comprising the Susitna Hydro- electric Steering Committee provide formal concurrence to positions developed by t~e Alaska Power Authority (APA)in response to committee recommendations.We concur with your proposal.However,in the event that we disagree with APA's position,we reserve the option of providing a formal response indicating what is required for Fi-iS concurrence. Sincerely, Field Supervisor cc:AOES JA Y S.HAMMOND,GOVERNOR / IH~I·.;\n.'r,n:Nl'01"lelSIt :\~U (~,\:UI':/I OFFICE OF THE COMMISSIONER /SUBPORT BUILDING JUNEAU,ALASKA 99801 January 22,1981 Mr.Eric P.Yould,Executive Director Alaska Power Authority 333 West 4th Avenue Suite 31 Anchorage,Alaska 99501 Dear Mr.Yould: RECEIVED ~,Cd 1;1981 \.,'";.J n-\8RiTY C:1/."-PO,Ii-I'•N..A~t-.,.. 'The Alaska Department of Fish and Game has considered your January 2 proposal for an agency consultation process by th~Al~sk~Power Authority (APA)through the Susitna Hydro Steerio!!,Committf~e.The process for evaluation and recommendation by stnff of this c'gency,and the form~ll agency concurrence ac tion of APA's developed pfJsition is accep table to this Department. I suggest APA work further with the Steering Committee to finalize the details of the implementation of your ptopos~d coordination/consultation process at their next meeting.Th~Steerip.g Co~mittee should be able to do much in the future to eliminate duplication of coordination and consultation effort,on both our parts,for the Susitna Hydroelectric Project. SinCQ:'~ Ronald o.Skoog Commissioner (907)465-4100 cc:A.Carson UNITED STATES DEPARTMENT OF THE INTERIOR GEOLOGICAL SURVEY Water Resources Division 733 West Fourth Avenue,Suite 400 Anchorage,Alaska 99501 January 26,1981 Eri c P.You 1d Executi ve Di rector Alaska Power Authority 333 West Fourth Avenue,Suite 31 Anchorage,Alaska 99501 Dear Eric: ".. /-'.. We concur with the b/o-step process of interagency consultation and coordination in studying the potential effects of the proposed hydro- power Gevelopment of the upper Susitna River basin outlined in your letter of January 2,1981. The Water 'Resources Division has no regulatory functions,so formal concurrence with your agencies actions is not within our field of authority.However,we can assist in advisory capacities.The Geologic Division expertise may also be available for consultation.The Conservation Division is the only Geological Survey division with regt.latory authority and they have a section that handles hydropower developments. Sincerely yours, Dnlled States Department of the Interior BUREAU OF LAND MANAGEMENT Anchorage District Office 4700 East 72nd Avenue Anchorage,Alaska 99507 nr:C~IVED r ~....~2 1981 2920 (Ou) JAN 30 1981' "". -, - "... Hr.Eric Yould Alaska Power Authority 333 West 4th Ave.,Suite 31 Anchorage,Alaska 99504 Dear Mr.Yould: This is in reply to your letter dated January 2.I9Rl,questioni.ng the official nature of the suggestions given during meetings with the Susitna Hydroelectric Project Steering Committee. All statements made at these meetings \~ith the Steering Commi.ttee ar.e at a 'Jorking level and are not to be construed as fiLM's official stand or policy. All official Bureau policy and positi.ons concerni.ng the Susitnil Project will originate from this office in wdttng with my signature or the signa- ture oEan acting District Manager. p Richard W.Tindall Distri~t Manager :DEPARTMENT OF THE A~\IV1Y ALASKA DISTRICT,CORPS OF ENGINEERS P.O.BOX 7002 ANCHORAGE.ALASKA 99510 REPLY TO ATTENTION OF; NPAEN -P L-EN Mr.Er ic P.You 1d Executive Director Alaska Power Authority 333 West 4th Avenue Suite 31 Anchorage,Alaska 99501 RECEiVED FFJ3 4 1981 ow rR AUlrlORITY NJ-,SKA r r. FEB OG1981 g'L. Dear ~0"Uld: This is in reSiXJnse to your letter of 2 .January 1981 concerning consultation wifh the Corps of Engineers on your stud~of the Upper Susitna River Basin. As stated in our letter to you of 12 June 1980,we are unable to participate in the Susitna Hydroelectric Project Steering Committee because of funding and manpower constraints,and \ve "Jill only be able to conduct the necessary reviews required for the issuance of permits under our regulatory program. I would suggest that the scoping process prescribed in the regulations of the Council.on Environmental Quality (see 40 CFR 1501.7)be initiated. This process,which would involve the Federal Energy Regulatory Commission (FERC),would help to define the scope of issues to be addressed and to identify the siglificant issues to be ana1yzed in depth in the Environmental Impact Statement (EIS).The Corps could pqrticipate in the scoping process and,possibly,become a cooperating agency with FERC in the preparation of theEIS. If further details are desired by your staff,Mr.Harlan Moore,Chief, Engineering Division,can be contacted at 752-5135. LEE R.NUNN Colonel,Corps of Engineers District Enginp.er Thank you for the opportunity to consider and conunent on the proposal. \..'Janet HcCabe Regional Director Sincerely, lr i 1 1i /-/11 {"/~(t:-f R E C;::I V E D ;C8 6 1981 J.,LASr.:A rOVIER "UTHORITY 4 1981FEB 1011 E.Tudor,Suite 297 Anchorage,:\Jasko '19503 Tde.('107)277-1666 l~~~ed States Department o[~t\le Intenor I-IERITAC,E CONSER V ATION AND RECR EATioN SER VICE .ALASKA AREA OFFICE \~e concur with vour recommendation of January 2,1981,concerning the expanded role of the Susistna Hydroe1ectic Project Steering Committee. However,we ,would remind you that we also have .1.separate coordination and review function associated with the license application Exhibit R. Mr.Eric P.You1d Executive Director Alaska Power Authority 333 West 4th Avenue,Suite 31 Anchorage,Alaska 99501 Dear Mr.You1d: A800 1201-03a RP IN REPLV REFER TO: U.S.E ~.-'·....0 N MEN TAL PRO TEe TIC.';i G ENe Y ~\,,~O sr-4~("REG ION X v -r ..,,'~~1200 SIXTH AVENUEi~W R E C U1AJrfi.D:,WAS H I N G TON 9 8 1 a 1 "\~"'1-t~(PRO'f.V"{)r E'c5 9 1~J 81 !{l f'l REPtYTO ,.,!r.~'."..PO\·\'l.-:':'/._;:·~J·lIJ A.TTN Of:MI S 443 I'...··~·... FEB 05 1981 Eric P.YOuld.Executive Director Alaska Power Authority 333 west 4 Avenue,Suite 3i Anchorage,A1aska 99501 Suoject:Susltna Hydroelectric Project Coordina~ion ~roc2dures Dear Mr.Yould: Tnank you for your letter proposing a two-step process tor the coordina- tion required under the Federal Energy Regulatory Commission regulatlOns and the Fish and Wildlife Coordination Act.We basically concur with your proposals.However,we may have further comments on the issues dealt \"ith in this coordination process once more intormation on each subject is available and the comDined etfects of tne project become more visible. It is our understanding that so far the Susitna Hydroelectric Project Steering Committee has worked on the procedures manual for the 1981 flela studies and is now in the process of starting up a subcommittee to deal with possible mitigation for wildlife impacts.Other issues,lncluding possible mltigation for fisheries lmpacts,are to be deait with iater when more information on the resources to be affected wlll De available. We would like to be kept informed of both the steering commlttee and subcorrunittee meetlngs and agendas so that we can participate more actively when items affecting tPA's areas of responsibility or expertise wil I be considered.For now,most of our involvement will have to De by letter and teiephone due to personnel and travel constralnts.Withln our limitations,we will try to be as responsive and nelpfui as possibie. tPA's coordinator for this project wil I continue to be Judi Schwarz,of my staff.She can be reached at (2U6)442-l2~5. We look forward to working with you in the future.It we can be of assistance,please do not hesitate to ask. Sincerely yours, ElJ.:,"-10i eDdy- EllzaDeth Corbyn,Chief Environmental Evaluation tiranch U.S.DEPARTMEW·--I"COMMERCE National Ocaanic l......Atmospheric Admlnlgtrlltlan NationaL Ma~ine Fisheries Se~ice P.O.Box 1668,Juneau.ALaska 99802 - nl~CL:JVED Mr.Eric P.Yould Executive Director Alaska Power Authority 333 Wes+4th Ave.Suite 31 Anchorag~,Alaska 99501 Dear Mr.Yould: We have received your letter of January 2,1981,regarding the involvement of the National Marine Fisheries Service (NMFS)in the planning and study of the proposed Susitna River Hydroelectric Project. We recognize the need for a "higher level of involvement"onOthe part of our agency,not only due to certain procedural requirements but the fact that the proposal has reached a more advanced stage of study.To this end we have been participating as a member of the Steering Committee since July,1980.We feel this involvement affords us the opportunity to evaluate project studies and provide any input we may feel is necessary.. Regardless of our status with the Steering Committee,we feel formal agency concurrence with all policy matters and deliberations should be obtained and therefore.agree with the process you have suggested. Sincerel¥~~/':.--'~~:~~{z!)/ i I DIVISION OF POLICY DEVELOPMENT AND PLANNING .I / / f i JAY S.HAMMOND,Governor POUCH AD JUNEAU.ALASKA 99811 PHONE:465-3513 February 19,1981 ""\"\',:Dl.-'-''-.- ,-,B 2 co,19 BlI'c ,.-" ~1r.Eric Yould Executive Director Alaska Power Authority 333 West Fourth Avenue Suite 31 Anchorage,Alaska 99501 Dear Eric: On January 3,you sent a letter referring to consultation and coordination with various federal,State and local organizations in the study and assess- ment of potential effects of hydroelectric development in the Upper Susitna River Basin.Your letter requested my concurrence with your plan or suggestions for its improvement. Frankly Eric,the paragraph in your letter that describes your plan is somewhat brief and general,making concurrence rather difficult at this time. r agree,however,that the study being undertaken is one that should have a very high level of involvement by interested State and federal agencies as well as potentially affected local communities. r suggest that a more detailed description of the workings of the Susitna Hydroelectric Project Steering Committee be provided.What may also be appropriate is the use of your public participation staff to serve a state government coordination as well as a public involvement function.The staff could document and disseminate the proceedings of the steering committee to a wider governmental audience.Such communication could occur prior to formal Authority position formulation and smooth the process of required formal concurrence with such positions. As for meaningful involvement of State and federal agencies in your assessment, r am enclosing a copy of Administrative Order No.55,rlescribing the Major Project Review (MPR)process.This process might be appropriate for the Steering Corrmittee.The process described can be used by any unit of State government and is designed to ensure that a~propriate State agencies are involved in analyses from the outset and that each assessment is highly issue oriented.The technique can be used to involve federal agencies and the public as well. Mr.Eric Yould -2-Februaty 19,1981 .... The MPR questions can be modified as needed and a schedule can be prepared that indicates points at which cooperators are to tie in to the process.We generally include a public review draft in the time line for an analysis. We have also found that it is essential to the success of the MPR process for the lead unit to be able to sufficiently detach itself from its own project goals and objectives to administer the analysis in a neutral and objective fashion.One solution is,of course,to have the analysis administered by a separate agency. Eric,r hope that at least some of these ideas are Dseful tci you.From your letter,we are not too certain as to \lJhat involvement process you had in mind. Please let me know if we can be of any assistance. Sincerely, Frances A.Ulmer Enclosure S te.L <:0 f Alas );2 -~~=~nistrative Order No. SL!ojec'L: l];Jcer i:he authoricy of Art.II::',Sectlo:;s 1 2;JC 26 0::t~:e /.lc.sL2.Consti- tution,and AS 44.19.880,2nc ~iven the neec ~o,tioely,cor:siste~t,and thorough evaluation of pTopc~ed ~ajor projects or 2ctivities,I order' that tt,follouing revie~process be instituted: 1.Certain \-.'ill be Revie'-'. projects, desig0l2ted because of their s[ate~ide br regiO;J21 significance by me 2.S wajor projec:.s subject.to 2 l:Cjc'f Project 2.An~state agency to ~~ich I assign thE:lead res?onsibility for conducting 2.}~cjor Project Re\iie·\ooo,~S[-IC.~1 pr e?E!"c 2nc sUDwi t to De ,,:'1e info~c.tiO:1 contc.ine.G 0:1 "ne [':-ojE:ct ,!'rie.lvsis 5,,;::::.c:-;'Sheer (.!,;:tachrnent ;'.)~"i thin 1 a Gays of t'r'EO 2ssig;;::;e"i:. ~.By the assigned ~E{e,!he le26 2gency £~21~?~E?2re 2~d s~b~i!to me a prelir.,ina-r-y ?ro.iect An21vsis ',,"::ic~'"c.CG:-E::.'ses t'ne e·jc.luction factors specified by ~e (~tte.ct~e~:3) ~.1~~~cii~tEly upon recei~~U~the ~rEli~.~~2~Y ?~O~Ect AG21 v sis i the Division of Policy DEvElc?~!ent ~n~?lE~~ing (u~D?):Of£ic~of the Governor,shell fo:--~'c.!'c i',fo:-::c.tio"c.l cCj:-:'es to ecc;-;2::::ecLed or interestEc gO\.le:":1;ll€7:'Lcl G~E:nc;·..c"."l.[-IC c.ss~g;~ec CZ'LES E2.C:-l 2gErJCy s~2ll sub~i:LO DPD?ic5 re,ie~2~C CC~5en:. -'.During the period of agency !'evie~of the preIimi"e.ry Froiect .~.nc.l:'sis,'Lne Public :O'fu:J Dc DP]?,in cC'"s\J~,r.:ion ~'it'n ,:ne lead 2gency,shall conduct one or ~~TE:public ~eEt~ngs in thE:affected c.rea(s)for t;'ie purpose of receiviT'g public CC::-:8E:l,ts on Ihe project or ections. 6.By the assigned oete,D?DP shc.ll suD:::it in ~-:itin:s to the lead e.gency.a suw,;n2T')'.of the r€vie;.:2lang.'~'it:r'J reco;::;2enc2.tio~s for the final Proiect Analvsis. " /.3)',the 2ssigne'd deIE,tne Ieee 2ge"cy,l;-,.conjuOlctior-.'~--,-;:il D?D?, shall prepare 2nG suDr..it to mE,in '-7iting c:1G verb21ly,a fina.l version of 'th~Project Anc.1"sis.Tne Project A:;clysis 5;-,211 include dissenting vie~s,recQ=~E~~atiD~S ~or furthe:2ctio~and,~nere eppropriarE s?ecific~oncitions or ~itig2ti0~~E2su~es ~ecessa.ry for state a.pproval of the project or 2ction. 8.No design~teci ~2jor project or 2c:ic~~ill be 2??=O\led prio~to The cO:i:pletion of the p~oce5s ceSCriD2G c'::Jove,uTiless 2.?ricr '~~itte';"l ~a.iver of necessity has been ob:ci~ed from mE. 9.tDe revie~specified ~n this cr~er ~~Ell be cDordin2red ~i;:h proce- Gures cO:Jtai:1eG in f..S L;6.~5,:':1\':'rC':-:.::-,e;-,t al ?rocE:'c.u:ce Coo c din2tion Act,2nd ot~er S;:2te revie~processes,2S 2?plic2ble. -1- 10.J~o 'J~_.ov"f ~":Dn 2bove .is to 2'e "'-...e ....-......r..-pc ~,.:_-~.....:e:~p ~_...~;"'''','''_~a _..l _,."':L_.-u.l __.-__-...c .._ S t 2 -'C U L.0 r.E qui r e::>e :i t 5 C:G.nyc g e ':"1 C :~':t...e :l S ~'w c :-;CE:O f ?=.:-:'.its . - ,.... 11 .Tnis c:'cer snell t2):e e.:f e.cc ':'::'n "7:-,""'--;-..-.'.....,.J _'--'~ De~cTi"tion Erie:6eseTiption of scope,nC-lure,end ocjcc::ive:0;:;)cojec7.or c.eLl.en, ~neluei~£locctio~of ?roject,eSLi=2.tec sec.rt 2~C cc~~~etion eCLe, Es-.:i::c.ted cost of ?roject,stcte i,I,ETEst ir;,:TOje:CL. StELe Action Recuested/Recuired ?2 =-=.:.:s sou g h L I WY Co b e 71 C Y ;res O"J ::c e s CO~SL~uc~ec;~ine~cl O~ctne~righIs 1 c C~"(:c.c :.s ,:e2SES,c -r'L..L ,_. :'0 be LE~~A~€ncy responsibili~y ?!cjec~i~21ysis. O:~E:Egencies E~d incii\'idu~ls 2~signe~~o :hE ?:O~fct 2nE~)~sis effort ~~c :heir res?onsib~lit~es.?rcpcsec co~::cc~~2~C~5~SLC~ce. ?Teli~in2ry Project A~21~sis ( .:'.gE:iCY end ?ublie Reviel.'------( Su~~cry Report ( ~i~21 ?roject Analysis ( cc:ys r:-c:-:GO"\le:-ncrl~2ssigr-~ent) ccys :i"C;;;?:Eli2i~;c7"Y Project );_Ll2~ cc;s :r~Agency 2ne ?~Dlic Revie~ Gcys Irc Sll::~c.~y P~E?Ort) 1.WhEt ch~nges would be tIl income for current resident Al~sk~ns over (construction 2nd operctionel phcSES)? life OT t~e project 2.., c~~nC2S Expected to result from the project? c.Whet proportion 07 jobs ~,e e~p~c~EC ~o ~e occupied by current Alcskens? ,\·:hct ere the cn~rccterist~cs 0,:i"::::SE jo::;s (s=::sDI:2.1~t.Y. DOES the project contribut~tc lcn;-run 2conC~1C stabili~y? 7rom the project? to result roeciblod:s i:.ffec"L. economic 7easibility of c project? CC:T:T:'.mitv \'!el"l-oeino Hhetc he n9 esc re ex pec ted i n t i:e c;J e :~-:.Y,2.\'c.i 1 c.bi 1 -;t y :or demend for govern~~ntc.l goads,s~,v-;ces Dr fecilities? .' 3.\·:hi:t i eCi:1 populEtion chenses f_C\;:...:.) conn iets ordincftC:~.s,reven~=-generctl~g proposed project? Fisccl 1 .\'.!h c.t E'"f E C t \','0 U j d the Pf 0 j e c the \'e :J nth e r:::::b=.1Co nee a f s t Co t e t.he pr-cject? R~S8~rc=Utilizction Effect or other resource VelUES?f2su1:in irrEYersibl~ 2.~ill the croject effect fish 2nd wi~dljfE D~JulE~ions or their hc.bitc.t?Will these Effects b2 shert-term Dr ldng-ter@ in nature7 W~11 the project subsistence feso~rc:::s?.........-•v, chc.nges in ffi)gr2tion p~ttErns>less 0,spECles,dislocc.tion,OJ ~Yc.i12bi)ity changes expected? 4.~ill the project effect designated Of sDecific~11y defined wilderr historic:wc.tershed,rEcreEtion~l C~~c2nic Er2~S? hec.i:n or sC....eLY of end quelity contro1? -2- - 1.. 2. 'Ioes the project invoive tEcnnolo_oicc'j,envirc;-.:i',=-n72:'I,-..1-"-7ir'U'!Clc,, .or economic factors which h~ve'~hir_~h dE~r~c-c-,-11~CC-~-~. --...,i ~''-:::ii:y or risk To ,.,.hat extent is the existing dc~c-kc'se c'0 ",qU?TC L---------l.O cns ....·er the above quest.ions? 3.Are there external factors (e.g.~nation~l or intern2tion~1) which fig~re prominently in the SUCCESS or failure of the prbject?' 1.Are there economically fe2sible 2nd sociclly 2ccept2ble ~ltern2tives for accomplishing the cbjEct~YeS of the project? -2.be the implications of Is the proposed project or action cc~p2tible wit.h plcns or policies? 1 O~~1 -2.What.permits,licenses 2nd/Dr government2.1 (stct~>10cc.i cnd/or federc'l)approvals are necessc.ry? 3.What is the timetable for various St.cQES of the projec~?How 'flexible is this schedule? - 4.~h2t mitig2tion m!!SUr~5 or stipul~tions c~n be idE~tified to mini~ize the confllcts or prcblE~sid2~tifiEd 2b~VE? ~~&1r~@~~~~~~t~I ~YSHAM.ONO.'OVERN" Ot:PT.01;'I~N\!lnON :U.~NTf\l~CONSI~&n',\rl'ION / II POUCH 0 -JUNEAU !I!J811 Harch 2,1981 Mr.Eric P.Yould Executive Director Alaska Power Authority 333 West 4th Avenue,Suite 31 Anchorage,Alaska 99501 Dear Mr.Yould: j'.::.').\ ".J-\\.... \.".' ".~ , ' I :~..: /.... Your letter of January 2,1981 proposes to expand the function of the Susitna Steering Committee from that af an advisory body to the study team to one of performing evaluations and structuring recommendations.I am happy to offer the resources of this agency to serve in that capacity to a reasonable extent. It is not clear to us,however,precisely what may constitute "items requiring consultation,"as the only substantive matters to come before the Steering Committee have been review of the field procedures manuals regarding Task 7 of the Plan of Study,and review of the preliminary screening of poten~ial hydro sites.Apparently,a more direct link with the Power Authority is anticipated,rather than simply with the study team,since your letter indicates that Steering Committee recommendations will be considered by the Power Authority.We will look forward to additional information, at an appropriate time,concerning matters that may be brought before the Steering Committee,and the action requested of the committee. Bob Martin will be the representative of this agency to the Steering Committee as of this date.Bob is the new supervisor of ADEC's Southcentral Regional Office.'Bob will receive whatever support he needs from Dave Et~~~~ant,who has been our representative in the past al,:ld:Who will~ntinue as Bob's alternate.<'\ ~5-'..//--~----t/L-A---~LJv'(~ /"'E~.-·M{j'e1ler Commissioner cc:Deena Henkins,EQN· Bob Martin,SCRO ..... -DI VISION OF RESEARCH &DEVELOPMENT fA r s.HAMMOND.SDYEINO' 323 E.4TH A VENUE ANCHORAGE,ALASKA 99501 """! - June 5,1981 Eric Yould Executive Director Alaska Power Authority 333 W.4th Avenue,Suite 31 Anchorage,AK 99501 Dear M.r.Yould: 279-5577 FU=CEIVED JUN-9 1981 'A/.ASY-A POWER AUl.'iORITY ..... The purpose of this Ie tter is to transmit to you a proposed revision in your June 3.1980 letter stating the role and objectives of the Susitna Hydro Steering Committee.The Steering Committee members feel the following more accurately describes the role and function of the Comrni ttee. "The Alaska Power Authority through its consultant,Acres American Incorporated,is carrying out a 3D-month feasibility study of the proposed Susitna Hydroelectric Project.Because of the magnitude of this study,effective interagency coordination will be best accom- plished through formation of a Sus·itna Hydroelectric Steering Committee. The function of this committee would be to provide coordinated exchanges of information between the Alaska Power Authority and interested resource management agencies.Through this exchange,the concerns of all agencies involved would be identified early and hopefully prevent unnecessary delays in the progress of these feasibility study,appli- cation for the Federal Energy Regulatory Commission license to construct, and Environmental Impact Statement review. As proposed,the Steering Committee would be composed of representatives of resource agencies with responsibilities pertaining to the Susitna Hydroelectric Feasibility Studies and/or the project's environmental consequences.We therefore invite your agency's participation . The committee would provide for interagency coordination through joint review of project related materials and development of more informed and uniform positions representing all resource interests.We believe this will provide a more efficient process of information exchange. Proposed objectives for this committee are to: 1.Review and comment on study approaches throughout each phase of the planning process; Eric Yould 2 J£5,1981 2.Provide a forum for continued project review of all aspects of the studies,for a timely exchange of information,and for recom- mendation of study redirection,should the accomplishment of specific objectives be in jeopardy; 3.Comment on compliance of the studies with state and federal laws, regulations,Executives Orders,and mandates as they apply to fish and wildlife resources;and 4.Provide unified steering committee comments to the Power Authority. Should your agency elect to participate in the committtee,we recommend that your representative have a technical background enabling him to comment on the adequacy and approach of ongoing and future feasibility studies,and be able to speak knowledgeably on the policies and procedures of your agency with respect to the review of the Federal Energy Regulatory Commission license application for the project and the subsequent Envirorunental Statement (ES)." If you have comments or suggestions concerning these proposed revisions, please advise. Sincerely, ~~ Al Carson Chairman Susitna Hydro Steering Committee cc:Steering Committee r·--:- ALASKA POWER AUTII()RITY 334 WEST 5th AVENUE -ANCHORAGE,ALASKA 99501 Phone:(907)277-7641 (907)276-0001 December 10,1981 R£CEivED Mr.AI carson Alaska Depart1reI1t of Natural Resources Research and Develq::rrent 555 Cordova Anchorage,Alaska 99501 DEC 14 1981 ACil ..""",..muM mlilJltrORATED Dear Al: In lc;te November,1981 you approached Ire with sane concerns relative our on-going effort to solicit fo:rnal coordination on various aspects of the Susitna Hydroelectric Project.This led to a series of neetings between ourselves and the Susitna Hydroelectric Project· Steering Carrnittee.To broadly surcmarize those events: I FILE'P5700 F"'"•" SEQUENCE NO. ;=:d/15".. Acres Arcerican Incorp:Jrated,acting for the Po.ver Authority, has camenced circulation for fo:rnal coordination certain building blocks of the studies that will form the basis for a project licensing recamendation. 1. 2.In most instances the agency heads (addressees of the formal requests for coordination)referred the request to staff for analysis.AlIrost without exception the staff involved also had been serving on the Susitna Hydroelectric Project Steering Ccmnittee.Largely due to this relationship,the individual agency staff rrernbers elected to use the Steering Corrrnittee structure as a vehicle to discuss their fOI'l'IE.l coordination concerns.As a result of rnul tiple interactions between the Steering Ccmnittee and the Pewer Authority,a number of issues have been clarified and options for agency response to the Acres request for formal coordination have been identified. 2.There has been no decision made yet by the PONer Imthority, the State legislature and the administration as '1::0 whether there will be an application to the FERC for the construction of the project. The Steering Comnittee has sl..1I1l"Parized its concerns as follo;.;s: 1.In sane cases,the docurrentation of field study results is not available coincident with the request for agency cament on aspects of the project. ALASKA POWER AUTKORITY SUSHNA 1-·-'-1-...'..--j--;I.--T:'l ?1iLEj- Mr.Al Carson December 10,1081 Page 2 3.Sore of the agencies are concerned about responding to bits and pieces of the proposed proj ect without being able to evaluate the entire proposal. 'Ib clarify the Paler Authority intentions relative the request for formal coordination,it is appropriate to look to basic intentions and objectives.The present and prq:x::>sed PERC regulations clearly encourage pre-application coordination;First,to assure that the project planning pro::::ess has taken into account IX'licies and guidelines of local,state and federal agencies,and second,to assure that the applicant has solicited agency ccmrents and concerns and has attempted to address them.Specifically,the proIX'sed PERC regulations (anticipated to be in effect by tiIre of license application,July 1,· 1982)require a request for fornal coordination fran agencies,provision of up to of sixty (60)days response tine to those agencies,and inclusion of applicant response to agency fonra.l caments in the license application.Therefore,one major purpose ~or the request currently circulating is to comply with PERC regulations. The Pewer Authority is anxious to accarrrodate agencies and the Steering Carrnittee in the decision process.We have derronstrated this in the past and wish to continue that policy.OUr requests for fOJ:Tr6'l coordination are very much intended to acccmrodate consideration of agency comrents in the formulation of the project and in the decision process leading to the Pewer Authority project licensing recarrrendation. Clearly,our ability to use comrents in this fashion is very much a function of when we receive them. . In response to regulatory require.rrents,and to our best judgerrent of when agency cornrent v"ill be rrost productive we perforce must persist· in our requests for fOJ::1T\3.1 coordination.We hasten to add,hewever, that we willingly accept interim carrrent,infornal carrrcnt,or any other variant that gets the infonration to us in a tinEly fashion.Heanwhile, we will attempt to make available pertinent dcx::umentation of field studies as early as possible so as to assist your review. I hope this sunmary assists you and your colleagues in deciding hew to resr:ond to our requests for forrral coordination.If other facets to this action errerge,I would welcare an opportunity to further discuss them with you. FOR THE EXECllI'IVE DIPECIOR 2I:uttl~ Dav:d D.\'b::niak ) ProJect Engmeer cc:John IavJreYmce,Acres Anerican,Buffalo ALASKA POWER AUTHORITY 334 WEST 5th AVENUE -ANCHORAGE,ALASKA 99501 December 17,1981 Phone:(907)277-7641 (907)276-0001 - Mr.Al Carson State of Alaska Department of Natural Resources 323 E.5th Avenue Anchorage,Al?ska 99501 Dear Al : Just a quick note to advise you we will be meeting with the Cook Inlet Acquaculture Association on January 21,1982,5:30 p.m.in the Kenai Borough Building.This meeting will also be open to other special interest group5 and the public,who will be notified via direct mailing and newspaper notices.~Je will be discussing the probable impact of the Susitna Hydroelectric Project to the anadromous populations. You might want to pass thi's information to your colleagues on the Steering Committee.Your,as well as their,attendance would be welcome. - ..... - FOR THE EXECUTIVE DIRECTOR DOW:mlj cc:R.Mohn,APA N.Blunck,APA J.Lawrence,Ac res. 7};JJ ·/~Vid IV wozn~lrMUJ Project Manag~ JAr s.HAMIIOI/D,&OrEINO' UEI»;\nT~IENT 0"~i\.TIJlli\l.1l.;SOIJIU~ES DIVISION OF RESEARCH &DEVELOPMENT I I / ( I f Pouch 7-005 ~ ANCHORAGE,ALASKA 276-2653 ~99510 c- January 14,1982 Dave Wozniak Project Manager Alaska Power Authority 334 West 5th Avenue Anchorage,AK 99501 Dear Dave: Per our earlier discussion,this memo identifies the topics the Steering Committee members believe to be of mutual interest to Dr.Leopold and ourselves. I want to pmphasize that the Steering Committee members recognize that Dr.Leopold s role on the External Review Panel is oversight in nature. Thus,the Steering Committee members will be leading the discussion on the topics listed below.Our objective is to review what we believe to be the most important Susitna Hydro-related issues in Dr.Leopold's area of interest and expertise. The issues and brief descriptions follows: 1.Fish and Wildlife Studies.Discussion of scope,timing and current status in relation to Susitna hydro feasibility decision making schedule. 2.Fish and Wildlife Mitigation.Current status and summary of miti- gation Review Group meeting of 1/20/82 (I understand that Dr.Leopold will attend 1/20 meeting). 3.Instream Flow Studies.Relationship to mitigation,downstream impact assessments and power generation-related flow regimes. 4.Access to Proposed Dam Sites.Implications of route alternatives and public access on caribou,moose,and waterfowl. 5.External Review Panel's schedule,and products? Committee to continue a level? Role in the Future.What are plans, Is it useful for Dr.Leopold and Steering dialogue?If yes,at what frequency and - ~, Dave Wozniak Sincerely, Al Carson,Chairman Susitna Hydro Steering Connnittee cc:Steering Committee Members Reed Stoops 2 January 14,1982 November 24.1981 P5700.11 .92 1.1297 5usitna Hydroelectric Project Fonnal Agency Coordination If I can be of further help,please let me know. Sincerely, #John D.lawrence Project Manager JDl:dtp Mr.David Haas Offi ce of the Governor4DivisionofPolicyDevelopment and Planning Pouch AW Juneau,AK g9811 Dear MI".Haas: Cbry As discussed yesterday.I am enclosing a list of all people within state and federal agencies to whom we are sending 5u5ftna Hydroelectric Project Reports.The list is keyed to explain who gets which reports.we are attemp1ring to insure that each agency has the opportunity to review reports dealing with resources or issues for which it has jurisdiction. WILLETT WITTE BERRY n ..--:~iX'{1 ,-(,! II';) //\~J..#. ~....'fi.4- LAMB LAWRENCE l,S'~R V ~A GH f--..-[-f- CARLSON FRETZ JEX LOWREY SINGH .I V·'11 l 11 A HUSTE';ll..'U,. eOVE CHASE f-,.- '-- Enclosure xc:Alas~a Power Authority 0 WILLETT I WITTE I BERRY I ....!.HAYOEN ~LAMB LAWRENCE (SINCLAIR IVANOERBURGH ''''''c.1 '\. CARLSON FRETZ JEX LOWREY SINGH 1- HUSTEAD-BOVE t-CHASE I;;:~ - ifllilllf!llt SUSITNA HYDROELECTRIC PROJECT REPORTS CIRCUlATED FOR FORMAL AGENCY COORDINATION NtteER KEY Plan of Study 1 1980 Envi ronmenta 1 Sunmary Report 2 1980 Fish Ecology Annual Report 3 1980 Plant Ecology Annual Report 4 1980 Big Game Annual Report 5 1980 Furbearer Annual Report 6 1980 Birds and Non-Game Mammal Annual Report 7 1980 la~d Use Annua 1 Report 8 1980 Socioeconomic Annual Report 9 1980 Cultural Resources Annual Report 10 Transmission Line Coaridor Screening Report 11 Development Selection Report 12 1981 Final Subtask Report 13 Draft Feasibility Report 14 Regional Administrator Region X U.S.Environmental Protection Agency 1200 South Avenue Seattle t WA 98101 Col.Lee Nunn District Engineer U.S.Army Corps of Engineers Anchorage District P.O.Box 7002 Anchorage t Alaska 99510 Mr.Keith Schreiner Regional Director t Region 7 U.S.Fish and Wildlife Service 1011 E.Tudor Road Anchorage,Alaska 99503 Mr.Robert McVey Director,Alaska Region National Marine Fisheries Service NOAA P.O.Box 1668 Juneau,Alaska 99802 Mr.John E.Cook Regional Director A1as ka Of f ice National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 Mr.Larry Wright National Park Service 1011 E.Tudor Road t Suite 297 Anchorage,Alaska 99503 Ms.Judy Schwarz U.S.Environmental Protection Agency Mail Stop 443 Region X EPA 1200 South 6th Avenue Seattle,Washington 98101 Mr.Ron Morris Director t Anchorage Field Office National Marine Fisheries Service 701 C Street Box 43 Anchorage,Alaska 99513 Reports sent/to be sent It 2 t lIt 12 t 13 t 14 It 2 t 11, 12,13 t 14 It 2,3 t 4 t 5,6,7 t 11, 12,13 t 14 1,2,3,4 t 5 t 6 t 7 t 11,12 t 13 t 14 1,2,9,10,lIt 12 t 13,14 1,2,8,11~12 t 13,14 1,2,11,12,13 t 14 1,2,lIt 12,13 t 14 I,2 t 11,12,13,14 ~I - - Mr.Ronald O.Skoog Commissioner State of Alaska Department of Fish and Game Juneau,Alaska 99801 Mr.Ernest W.Mueller Commissioner Alaska Department of Environmental Conservation Juneau,Alaska 99801 Mr.Lee Wyatt Planning Director Matanuska-Susitna Barough Box B Palmer,Alaska 99811 Mr.Tom Barnes Office of Coastal Management Division of Pol icy Development &Pl anning Pouch AP Juneau,Alaska~9811 Mr.Roy Huhndorf Cook Inlet Region Corporation P.O.Drawer 4N Anchorage,Al aska 99509 Ms.Lee McAnerney Commissioner Department of Community &Regional Affairs Pouch B Juneau,Alaska 99811 Mr.Robert Shaw State Historic Preservation Officer Alaska Department of Natural Resources -Division of Parks 619 Warehouse Avenue,Suite 210 Anchorage,Alaska 99501 Reports -sent/to be sent 1,2,3,4,5,6,7,11, 12,13,14 1,2,3,4,5,6,7,11, 12, 13,14 1,2,11,12,13,14 1,2,11,12,13,14 1,2,8,11,12,13,14 1,2,11,12,13,14 1,2,11, 12,13,14 1,2,11,12,13,14 1,2,9,11,12, 13,14 1,2,9,10,11,12,13, 14 1,2,8,11,12,13,14 DIVISION OF POLICY DEVElOPMENT AND PlANNING GOVERNMENTAL COORDINA TION UNfT December 2~1981 Mr.John D.lawrence Project Manager~Susitna Hydroelectric Project Acres American Incorporated The liberty Bank Building~Main at Court Buffalo~New York 14202 Dear Mr.lawrence: JAY S.HAMMOND,Governor POUCH AW (MS·0765) JUNEAU,ALASKA 99877 PHONE:(907)465-3562 RECEIVED DEC 7 1981 FILE P5700 P . J /.9,;) David W.Haas State-Federal Assistance Coordinator Si ncerely ~ !lt~~k',;J~vJ This letter should clarify a telephone conversation we had on November 23~1981 and the role of this office in reviewing subsequent materials relating to the Susitna Hydroelectric Project. Our office recently received copies of correspondence addressed to Tom Barnes~ formerly of the Alaska Office of Coastal Management (OCM).We conduct Alaska r-~C~o:astal Management Program (ACMP)consistency reviews for OCM as well as unified ALASKA POWER ate responses on many major projects.Thus~OCM notified us of this correspond-c~ AUTHORITY ceo In this regard~we'd first like to inform you that Ms.Wendy Wolf has r-_S_"_U_S_J_T_N__A__~placed Tom Barnes at OCM and will handle any future reviews of the Susitna oposal for OCM. I for future reviews,we would like to receive a mailing list of all agencies I SEQ~E~C/~NqO·c ntacted and a copy of the particular report.We would like to do an informa- ~~v 'onal review of the feasibility study when it is available.We would expect z::-ij c:i I t at an Environmental Impact Statement (EIS)would also be prepared for this 2~':~I s.jor project and that we would conduct an ACMP consistency review of it.If ~'I~.s i ~y u do prepare such an EIS~we would like to coordinate the mailing of such __I __,i -d cument with you to simplify our review procedures.We would,of course~like I iiJ::-",'.':t know if there won't be an IIS. -I ;/f'7",-:---1-i C"';"---p ease advi se us if you can cl ar1 fy any of the revi ew process and if you-i~:!ve any questions. ,11\;;+-·- l_l_I~!_(;i-!l.-(.' !~__E~~Lk'1==~:~:i 1 •!\1 R V 1--<:.Eri c Youl d ~APA :--I-H RC I . 1 1=1=)-'-=I=~I- -1--' -1~1-.- December 9.1981 P5700.11 .92 T.1338 Susitna ~droelectric Project Formal Agency Coordination • ~l..;)../t:.... will hopefully address the issues raised in your letar of December 2. We will send future correspondence to Ms.Wendy Wolf at the Alaska Office of Coastal Management..Thank you far notifying us of change in personnel. We will send you copies of all future reports issued formally for agency review.My letter to you of November 24.1981 listed all recipients and the reports they will receive. This formal agency review process we are conducting is for several purposes.Although we have had many meetings with agency personnel.we have been informed thefr views do not necessarily represent those of their agencies.To insure c~ncerns of the agencies are addressed and incorporated. where possible.into project planning and to receive agency input on the studies,we have implemented this fonnal process whereby project reports are sent to agency Commissioners and/or Directors.In addition.the Federal Energy Regulatory COI11l11ssion requires docwnentation of agency input into project planning and mitigation. 4)The Feasibility Report will be issued by the Alaska Power Authority (APA). By copy of this letter.I will request you be placed on the distribution list. 5)The Environmental Impact Statement for this project wl1lbe prepared and issued by the Federal 1gengy o Regulatory Commission.on the basis ofa license application to be submitted by APA.should a decision be made to do 50 by the state.If you wish to coordinwte mal1ing of this document. I .5uggestyou contact Mr.Quentin Edson.Chief of the Environmental Division in Washington.D.C. Mr.David Haas te-Federal Assistance Coordinattr ta of Alaska ce of the Governor sion of Policy Development d Planning hAW au.Alaska 99811 Mr.Haas: - F eta WILLETT taWITTE' I BERRY lITf1 .J.'ivi an I ,/-,t rlUc I',,...-,~.. !'""'.LAMB t ,/'I-- LAWRENCE' SINCLAI1'!lAar H ~~'"k:.'-."./.,his , I /~981ICARLSON """FRETZ JEX ) LOWREY I SINGH I ~//J r .ro--"I v l .,) I HUSTEAD _l eaVE i ) I I CHAse 1""". 1 ~.h .1"'-' Mr.David Haas December 9.1981 page 2 I hope this clarifies matters.If.Y.you have further questions.please call. ~!jMGjJmh cc:£.Yould,APA Sincerely, ~ John D.Lawrence Project Manager F--'----' Dear Hr.Trent: .....WILLETT WITTE BERRY J I~I LAMB-LAWRENCE SINCLAIR VANDERBUn:tGH -":'~--~"- CARLSON FRETZ.-JEX LOWREY SINGH ~v:~ 1 HUSTEAD BOVE I""'" 1-<J'1.(,.,,,,,-..... iA P /tT'0"""'-./ CHASE- f-......... - November 25,1981 P5100.11.92 T.1301 Mr.Tom Trent Alaska Department of Fish and Game 2207 SpenardRoad Anchorage,AK99503 Susitna Hydroelectric Project Report Review As you diseussed w1th M1chael Grubb on November 24,1981. r am enclosing the following Sus1tna Hydroelectric Reports which were also sent to Mr.Skoog for ADF&G review and cooment: 1.1980 Environmental Sumnary Report 2.1980 BiQ Game Annual ReDort 3.1980 Fish Ecology Annuai Report 4.1980 Plant Ecology Annual Report 5.1980 Furbearer Annual Report 6.1980 Bird and Non-Game Annual Report As you sugge~ted we will in the future send reports both to Mr.Skoog and directly to you. Sincerely, John D.Lawrence Project Manager 1f.1G:dl p xc:E.Yould/APA R.Skoog/AOF&G Enclosures DEP.-\.GTM£Z'iY OF ~AT1JII..U RESOURCES lXVJSlO'IOF RESEARCH&DEVEl.!PMENT December 9.1981 fiECEIVEP Eric Yould,Ex~.utive Director Alaska ~r Authority 333 west 4th Avenue.Suite 31 A."'ichorage.AA 99501 Dear Mr.Yould: 2.SQ!..r:e of the reports 'p;hic.h agencies wi11 be requested to form:lTy respond to win not ~pre-::e-eded by the reievant data and study findings f~~ich the su:;;;;ary report and formal agency CQiW,'.ents should be based.An cbvious exa..r.:ple is the review of the 1931 draft annual re~rts is ~uired 2 ITiOnths after the draft fe-as1- bi11ty report reyiew. --~ I PG~----,ENSl/=SNT--I DWL'j'-MfiVr'-'' .-~~' j~FILE 'Several state and federal agencies,in recent weeks have been asked to " formally review and provide coanents on several doct!l!li!'flts relating to the proposed SUsitna Hydroelectric Project..Although the Susitna.Hydro~ electric Steering Co;mittee 1$an organization that is designed to pro'" vide infQrma.l advice and caooent on matters pertaining.to the Susitna. H.)'-oroelectric Project,JOOst '11"the steering c~ittee members receiYeii the formal agency respOnse request tha.t 'lIiaS S~'1t to the agency directors and cc:a:tissioners by Acres.it is primarily because of that fact that the steering c.omiittee feels that it is appropria.te and neo=ssary tD send ----~--.a letter to you at this time with respe...-t to the Alaska Power Authority·s'AL~:~o~~;£R re-~uest for formal agency coordir.ation and review on ela><ents uf the SUsitna SUS11:NA H"ydroel~tric Power Project. ,FILE P5700'As a result of concerns expressed by srsnbers af tl"'.e steerinq ~fttee.we ,..II convened a meeting on Oece:-.ber 2.1981 of the steerin9 c~ittee with ;EQUENCE~;.~RQbert Mohn and Dave Wozniak.of the Alaska Pmfer Autr;Oi'ity i'ltt-.onding. .,<3/85,OAt this steering c~ittee ~tin9.we were provided with our first gH~se of how the Alaska Power Authority intends to ce-nduct tJ-~ftrn'ial ccnsult.atiQn ;i and coordination reqUired for this project..The farnal coordination process ;::that is proposed in t.~August 12:1'1S81 Acres docu;r.<2nt to fric Toold.subject. Z KSusitna Hydroelectric Project Fo~~]Coordination Plan-.is conceptual1y appropriate but incomplete alid deficient.The following are probl~areas. 1'7""'--1----1 in the prop<}sed fonr.al coordination plan as described above; 1.The fonr.al coordination plan as proposed by Acres.has not b~n formally OJ informally discussed and reviewed ~ith the agencies from which the ?o~r Authority requires responses.This is pro· bably the !'nost significant objection we have with the approach of Acres.The contractor sent letters to heads of state and fe-deral agE=;rCies requesting s~~iftc C{>~nts on detailed studies and reports associated with the $usitr~Hydroelectric P~j~t without having a c~~lete understanding of the responsibilities and concerns of agencies. /1$!iITRl, 3.Tree proposed formal coordination plan.as described in the Au9ust 12,1981,riocurent fro;Acn!s to Mit does not accurately describe all tr;e parties and agencies who should receive t:et"'t4fn doc\Ble!1ta. The steering ctlililittee feels that the furcal coos\lltat1on process should proceed ina lilIOJ"e ccordinat-od and organized fashion in order to avoid umecessary CC'ASeqt.JenCeS caused by the problems.)Ijf!rrave identified abGft•...We affer''the following suggestions and ~ts: 1.lie.rec~that the APA.as soon as possible,convene a formal r;eetingwith agencies to establish the schedule,and the process for formal c:oordin-ltion for this project.In light (}f the proposal to have a complete draft feasibility plan available 01\March 15,1982. we urgetha.t the PeEr Authority cofiveneth1s ~ting and get this IBa.tter sorted out with the agencies before January "1982. Z.The formal coordination list that will be·us.ed for this project needs to be reviewed and approved by ager.cy representatives to ensure that it is ca;plete and ccmprehensive.At+...ached to this letter please find a series of additions to the B112/81 Acres list.. 3.R~.iew of the proposed F.E.R.C.regulations in voll.Se 46 ~r 219 of the Federal Register dated 11/23/81 identified a list of inforae- tion categories to be included in Exhibit E.Ca:;parinq these re- quirements to the 9/12/81 proposed coordina~ion plan,lIE find the fol1~ing agency review categories missing:. i}Socirecc.~ic sb:dies i 11 )6eo log i cal and soi 1s stud1 es We agree with the APA approach of requesting eariy fot.....;tl re'li~arrlf ~ts on policy related dcozents that are required in order trJ put the project proposal t0getr.er.For e~le.the rEq.u€st for revi50l QT t.t-~fish and wild- 1 ife mitigation policy before the specific mitigation prc?Dsal for the project is sul=mitted:to agencies for revielol an~catr.ent. In suma-.ary.the ~bers of the steering Ct":-,ittei!found the proposed fornal coordination plan to be revealing ar.-d useful to better ur.i!~rstand r.o~ag-e:ncies ~ill have to respond in order to ineet the needs of APA.~are particularly EllcrJuragea to see L'iat the instrecs fllilil study plan ~s planroed to be available forrevieiend c<W'""~t by agencies in Dece:ber of 1981_Since.this is such a critical el~nt of theSusitra Study Plan,thi~rleserv~s attention and re- sponse from the agencies as soon as possible. - - if)A1terr.ative dssigns,.locations ar.~er.€rgysources The steering comittee hopes that you will find the-~<:.oaiEnts arod ~­ tions useful and constructive and is anxious to continue to.provide 'infoti:lal review and ad'lice to the Pmer Authority. Sincerely yours, A1 Carson,Chairman SusiW Hydroeleetric Steering CCUlittee AC:dh cc:Steerir19 Coimi't'"...ee Reed Stoops Quentin Edson,Director,Division of Environmental Analysis,F.E.R.C. A.Starker leopcId ~- - .... - .12/9/81 R~additions to the 8/12/81 agency coordination list for Susitna Hydroelectric Project. water Quality and Use Alaska DNR.OF &G ..DEC·_ U.S ..A'tflf1.Corps of Engineers •EPA.NPS • F &WS,GS •Bl14,lftfS AEIDC Fish,Wildlife and Botanical .- Alaska Of &G -.DEC •OteRU.S.F &WS,&S. II N1FS.EPA ".8LM AEIDC Historical arid Archeological Alaska DNa (SHPO),OFt.G •DCRAU.S.NPS •BLM AEIOC Recreation Alaska DNR.OF &Gu.s.NPS •F-&WS,~~s Mat-Su Borough AEIDC Aesthetics and Land Use Alaska DNR,OF &G U.S.8LM.F &MS,NPS CIRI AEIOC General OPDP,OCM.Governor's Office 15 DEC 1~~1 DEC 21 1981 ACRES h.,-"I ORATED".·•....u.'-'•••"..."uur FISH AND WILDLIFE SERVICE lOll E.TUDOR RD. ANCHORAGE,ALASKA 99503 (907)276-3800 United States Department of the Interior RECEIVED' IN REPl Y REFER TO: WAES f'-'j":'- ,- -~,\•Eric Yould -,-,)I .~1/~E?Cecutive Director ;-·/iL]/-AD.aska Power Authority I_~II d.r1~h:;a:~~~;:~~99501 ,--'"I <,Dr ar Mr.Yould:;~~;~r~e u.s.Fish and Wildlife Service (FWS)has been contacted by Acres American,-;-7 "--,.rfgarding fOnDal coordination of certain aspects of the feasibility study forr'-r /-:/i tile Federal Energy Regulatory Commission (FERC)license application for the 1"-~.;r-~--srl sitna Hydroelectric Project.To date four document packets have been sub-;_:_,-!-m tted to us for formal review.These are the 1980 Environmental Studies !__'_--'I_!Almual Reports,Transmission Line Corridor Screening Report,Development j __>~.i S~lection Report,and the Fish and Wildlife Mitigation Policy. i __,::-'_dL_J I I !Initially,some confusion arose over these requests.In his letter of 'r--j-'r-:'\l~.bvemb.er 16,1981,Mr.John D.Lawrence (Acres)identified the sources of -;-'-'.-'-r----chnfusion,explained which documents were to be reviewed and extended the 1--,--~--;~mment period to 45 days.While we appreciate this clarification.we feel a :---..:-l--mhre formal and explicit plan for formal coordination of the Susitna Project -~hst be developed.Mr.David D.Wozniak of your staff addressed the Susitna ,....-,~~:---Hydroelectric Steering Committee on this subject at their meeting of :j--'::;_~ecember 2,1981,and presented th'r coordination plan developed by Acres 1Jtt..~.-~PI41etter of August 12,1981,from John D.Lawrence to Eric Yould).I I "I~M~.Wozniak's briefing was very beneficial to our understanding of this pro- -----cess;however,we feel it is important that the Alaska Po~er Authority (APA) understand the position of the FWSon this issue.The FERC regulations (Federal Register Vol.46.No.219.November 13,1981)require a FERC license application to document coordination with federal resource agenci~s in the· Exhibit E.These agencies must be afforded a minimum of 60 days for reviev and comment.As such we disagree with the 4S-day comment period suggested by your contractor.Additionally.there are several deficiencies vithin the Acres coordination plan vhich concern us;the first of these being the fact that no formal discussion as to this coordination has occurred.Thus,the contractor arbitrarily decides which documents are of concern to a particular2JJ~~:agency.and vhat level of coordination will take place.Formal contact should i~work to insure that all agency concerns and consultations are met so as toc7tJ~comply with the intentions of the FERC regulations.With the exceptioD of£.J;I-(/tt4J I certain.policy statements (e.g.Mitigation),the Acres plan calls for formal~~,(d ~agency 1Dput before necessary background reports and data are available.An/LIZ Y obvious example of this is found in the formal coordination plan-product list ,!2k,/. hie ..- - .- (attached to the aforementioned letter dated August 12,1981)where the Draft Feasibility Report will be released for agency review two months prior to release of the 1981 Annual Reports.It is unrealistic to aSSume that ffi;:Aningful comment can be generated in the absence of such information. We believe a meeting should be arranged by your office to define the objec- tives of the required coordination and to develop a plan suitable to both the APA and the federal resource agencies.In the interim we w~l attempt to respond in a timely manner to all appropriate project documents,but will withhold comment on those documents which must be supported or clarified by the results of other studies. Sincerely, AdJ:!:o£~ cc:FWS/ROES,WAES Quentin Edson,Director,Div.of Env.Analysis,FERC NMFS,EPA,NPS,BLM,USGS,ADEC,ADF&G Carson/ADNR Lawrence/Acres American DEPT.OF ENVIRONMENTAL CONSERVATION HECEIVED JA r s.HAM~~~Rf'9.fll 'ftU,.SKA POWER AUTHORITY .POUCH 0 -JUNEAU 19111 December 21,1981 Mr.Eric P.Yould Executive Director Alaska Power Authority 334 West 5th Avenue Anchorage,AK 99501 Dear Eric: The Department of Environmental Conservation has been contacted by Acres American requesting formal coordination and review on five Susitna Hydroelectric Project documents.These requests were received in October and November,1981.There apparently is some confusion as to what exactly was being requested.In his letter of November 16,1981,Mr.John D.Lawrence of Acres clarified the situation and extended the review period to 45 days.On December 2, 1981,the Susitna Hydroelectric Steering Committee met with Mr.Dave Wozniak of your staff.Dave presented the Acres coordina- tion plan.This document,plus Dave Wozniak's briefing,provided a clearer understanding of what we must do to be responsive to the needs of APA for the Susitna project. As noted by the steering committee's letter to you on December 9, 1981,there are several problem areas with the formal coordination process outlined by Acres.We are particularly concerned that DEC was not inclutled in the water quality and use group.Since DEC sets State Water Quality Standards and regulates water quality throughout Alaska,I feel our inclusion on the water quality review group is necessary. Review of the coordination plan leads me to recommend that it would be useful for APA and the appropriate agencies to design a single continuing process for review and comment on the Susitna Hydro- electric Project.Since we are dealing with a State-sponsored project,I believe it is appropriate and timely that the State agencies and APA also determine the funding and personnel needed for these efforts.Our contacts for this matter are Bob Martin or Steve Zrake of our Anchorage Regional Office.They can be reached by phone at 274-2533. UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National Marine Fisheries Service P.o.Box 1668 Juneau,Alaska 99802 .R E eEl V E:.D December 23 ,1981 DEC 3 11981 -mSKA P9 WSi AUTHORI1Y Mr.Eric Yould,Executive Director Alaskci.PowerAuthority. 333·W.4th Avenue Anchorage,Alaska 99501 -I - ,... Dear Mr.Yould: The National Marine Fisheries Service has been contacted by ACRES American regarding formal coordination of certain aspects of the feasibility study for the Federal Energy Regulatory Commis- sion (FERC)·license application of the Susitna Hydroelectric Project.To date four (4)·documents have been submitted to us for formalrevie~These are the 1980 Annual Reports,Transmission Line Corridor Screening Report,Development Selection Report and the Fish and Wildlife Mitigation Policy. Initially,some confusion arose over these requests.In his letter of November 16,1981,Mr.John D.Lawrence (ACRES) identified the sources of confusion,explained which documents were to be reviewed and extended the comment period to 45 days. While we appreciate this clarification,we feel a more formal and explici t plc;tn for formal coordination of the Susi tna Proj ect must be developed.Mr.David Wozniak of your staff addressed the Susitna Hydroelectric Steering Committee on ·this subject at their meeting of December 2,1981,and presented the coordination plan developed by ACRES (letter of August 12,1981,from John D.Lawrence to Eric Yould):.Mr.Wozniak IS briefing.was very beneficial to our understanding of this process,however we feel it is important that the Alaskci.Power Authority understands the position of the NMFS .on this issue.The FERC regulations require a FERC license application to document coordination with concerned federal agencies under Exhibit E.Agencies must be afforded a minimum of 60 days for review and comment.18 CFR §4.41 (f)(46 FR 55926,55937; November 13,1981).We interpret this requirement to apply to each document submitted to us for consultation,including in particular the drafts of Exhibit E and the license application itself.Moreover,we expect that while there may be documents which can be reviewed by us in less than 60 days,there are very likeJy going to be instances where we will need more time than that in order to perform a thorough review. One reason we expect to be accorded longer than 60 days for consultation in some instances,is that formal agency input is often to be solicited before necessary background reports and 2 data are available.An obvious example ofth,is is found in the formal coordination plan-product list,where the Draft Feasibility Report will be released for agency review two months prior to release of thel981 Annual Reports.It is unrealistic to assume that meaningful comment can be generated in the absence of such information. We are also concerned about another apparent deficiency in the proposed coordination plan.The decisions as to how coordination is to proceed are left to the contractor,who has discretion to decide which documents are of concern to a particular agency,and what level of coordination will take place.This approach has the potential for having the concerns of some agencies overlooked,and we would urge that the 'contractor make a special effort to insure that the consultations are as inclusive as possible. We believe a meeting should be arranged by your office to define the objectives of the requ~red coordination and to develop a plan suitable to both the APA and the federal resource agencies.In the interim we will attempt to respond in a timely manner to all appropriate project documents,but will withhold comment on those documents which must be supported or clarified by the results of other studies.. ~..~...'.'.".""'.'..'.,'...... ."'.: ..~~ I I I.. Mr.Ernest W.Mueller CorTlni ss i oner Al aska Department of Environmental Conservat ion Juneau.Alaska 99801 January 8~1982 P5700.11.92 T1415 - Susitna Hydroelectric Project Formal Agency Coordination Program Dear Mr.Mueller: As you are aware~Acres American has.on behalf of the Alaska Power Authority.instituted a Formal Agency Coordination Program for the Susitna Hydroelectric Project.This program has apparently resulted in some confusion among var·ious agencies as to its intent and scope. To resolve this.a meeting has been arranged for 10:00 a.m.on January 21. 1982~at the office of the Alaska Power Authority~334 West 5th Avenue. Anchorage.The purpose of th is meet ing wi 11 be to expl ain the rat ional e~ intent~scope~and regulatory requirements for this program. If you feel you could benefit from this meeting~your attendance is welcome. Sincerely yours. John D.Lawrence Proj ect Man ager MMG/jgk ACRES AMERICAN INCORPORATED .....:",.:.-,'~'.'(.'.,.:. .~~r .•:..;;:'_0":.:c.. Preceding Letter Sent To: Mr.John Rego U.S.Bureau of Land Management 701 C Street Anchorage,AK 99501 Regional Adminstrator U.S.Environmental Protection Agency 1200 South Avenue Seattle.WA 98101 Mr.Keith Schreiner Regional Director U.S.Fish and Wildlife Service 1011 E.Tudor Road Anchorage,AK 99503 Colonel lee Nunn U.S.Army Corps of Engineers P.O.Box 7002 Anchorage,AK 99510 ronmellta sheries Service 99802 nald 0,Skoog ssioner~ Department of sh and Game L~:n'f;a,u ~AK 9 Mro Ernest W.Muel1e~ ssioner Department of on JU,'ledlU~AK 99801 o Robert Sha\ly s c Preservation cer as Department of Natura1 Reso'urces 619 Warehouse Avenue il~r'~n~~,!o~AK 99501 APPENDIX El1B CORRESPONDENCE RELATING TO PLAN OF STUDY - APPENDIX 11.B PLAN OF STUDY The Plan of Study was circulated for review in March 1980 with public and agency meetings being held in April 1980.The Plan of Study was further dis- cussed with the Steering Committee in September 1980 with Environmental Procedure Manuals being circulated for review in October 1980.Comments on the Plan of Study and Procedure Manuals were subsequently received and re- sponded to. This appendix contains correspondence from'APA to the agencies responses concerning the Plan of Study and Procedure Manuals. to these comments are included. and their APA 's response Correspondence is presented primarily in chronological order.However,in some cases,a response to a letter directly follows the letter to facilitate-an understanding of the flow of communication.This results in an interruption in the chronological sequence~ Augus t 21,1980 P5700.ll T.375 RECEIVEQ ~.~1.1 ;• • . .~;,./.,r Alaska Power Authority 333 West 4th Avenue Su ite 31 Anchorage,Alaska 99503 Attention:Eric Yould Dear Eric:Susitna Hydroelectric Project Distribution of TES Procedures t-lanua 1s Enclosed please find copies of the TES Procedure Manuals as requested by yourselves and the Susitna Steering Comnittee.A distribution list is attached. Since Mr.Al Carson,Chairman of the Steering Committee is out of town until August 27,the distribution list for the committee is based on the key contact list as supplied by Don Baxter on July 18,"1980.Please advise if any changes are made in distribution. Sincerely, """ KY:pg Enclosures J.D.La\'1rence Project Manager DISTRIBUTION: Copies of all procedure manuals to: APA -E.Yould,R.Mohn USF&W -Don McKay DEC -Dave Sturdevant ADF&G -Tom Trent ADNR -Al Carson BlM -John Rego AEIDC -Chuck Evans Copies of Fisheries Manual: NMFS -B,ad Smith Copies of Manuals for Subtasks 7.05,7.06,7.07 &7.08: HeRS -Larry Wright MEMORANDUM DEPARTMENT OF NATURAL RESOURCES DIVISION OF RESEARCH &DEVELOPMENT State of Alaska TO:SUSITNA HYDRO ELECTRIC STEERING COHMITTEE ~1EHBERS (See Distribution List) DATE. FILE NO' September 4,1980 FROM: TELEPHONE NO: Steering Committee Chairman ,,'-t..:.;:r.fOW:::i A:':TH~RIT'f •-0 __-0 TIle purpose of this letter is two-fold: 279-5577 Summary of 7/17 and 18 Meetings and Review of Procedures Manuals I~ r ! r I I r ! """! I 1.To summarize the major points discussed in the July 17 &18 meeting of the Susitna Hydro Electric Steering Committee. 2.To transmit to you copies of the Acres American contractor's field manuals which describe in detail how they will conduct studies during the 1980 and 1981 field season. The first item of business on July 11 was discussions and decisions leading to the appointment of a chairman.Those in attendance agreed that Al Carson,Department of Natural Resources,would serve as chairman of the Steering Committee with Tom Trent,Department of Fish and Game,serving as Assistant Chairman.There were two representatives from the Federal Energy Regulatory Commission (FERC).Hr.Dean Shumway and Mark Robinson.A considerable amount of time was spent by Messrs.Shumway and Robertson explaining the role of FERC in the proposed Susitna Hydro Electric Project.The rest of the morning meeting was devoted to contractor briefings about the studies included under Task VII (environmental studies) for the Susitna plan of study.Two significant items were identified by this review.First,it was obvious from the comments from the agency representatives,contractors,and subcontractors present that the agencies were unable to provide a detailed/critique of the plan of study.This is because the widely circulated 'plan of study did not have adequate detail regarding methodology.approach,or scope of the proposed studies to enable the reviewer to make reasoned or useful comments on these matters.Acres American and their subcontractors stated that this level of detail would be found in their yet to be published field manuals which describe in detail the work that the contractors will be doing in the 1980 and 1981 field seasons.The Steering Committee members will be provided with copies oftheae field manuals for their review when they are available.The significance of this is that the studies that are peing accomplished under the Susitna plan.of.study for the field year of '1980 .are being carried out without benefi.t of review,' comments,or approval by the various state an4 federal agencies. Second,was a concern regardinghQw thesocio-econom!c studies being conducted under the Susitnaplan of stud)"related to the fish 12-G01 ..CA ....10/ltl Susitna Hydro .~ ~ctric 2 September 4,1980 and game impact concerns identifi.ed by agency representatives.It was agreed that the Steering Committee wil.l meet with the socio economic consul t.:lllts to learn hm.,r these studies rela te. The meeting on July 18 \.,ras devoted exclusively to revie\.ing in detail and discussing the studies that are necessary in the FERC filing concerning fisheries,hydrology,and instream flow.The most significant issue which appeared from these discussions was the need to insure that mitigation for fisll,wildlife and other environmental values are integrated into the project designs,etc. rather than being an add-on or appendage at a later date. The second purpose of this letter concerns revieH of the field manuals.Accompany1ng to this letter you will find copies of the field manuals to be used by the Acres American subcontractors .for carrying out various studies as discussed in a general way within the Susitna plan of study documents.Please carefully review these manuals giving proper emphasis to those studies which are included within your field of expertise and your agency's authority and responsibility.The intent is to have all tMe Steering Committee members review these manuals and forward your revic,.,r comments to me.I will then synthesize these comments into a draft letter from the Steering Committee to APA.Then we will meet to review and finalize the letter.For the sake of convenience and saving time in synthesizing comments,please place your comments and concerns within the appropriate framework as discllssed here:The review of the field mflnuals is intended to detail problems or concerns within the following six areas: 1.\.Jhat is the appropriateness and utility of the studies,i.e., do the studies attempt to answer the questions that need answering in light of the proposed Susitna Dam? 2.The scope of the studies,i.e.,is the methodology approach and techniques properly formulated to provide valid and germane answer(s)which will apply directly to the proposed Susitna Darn? 3.The study approach and methodology,i.e.,does the approach and methodology discussed in the manuals result in findings and recommendations which are or will be scientifically valid? 4.HOI"do the subtasks of the studies "hang together"to give a comprehensive picture of the impact of the ,project? 5.110\.do the various disciplines (e .g.,fisheries,seismology, engineering,recreation)study findings and recommendations affect the other disciplines?The answer to this question will identify the hierarchy of values that will be attached to various components of .the project when the "trade offs"decisions are made. Susitna Hydro f,\ectric 3 September 4,1980 ..... 6.\{hat other issues and con~erns did you discover while reviewing these manuals that need the attention of the Steering Committee? Please provide me your \.;rritten revie~"comments no later than close of business,Friday,September 26,1980.If you have questions, comments or revisions on the matters discussed in this letter, please contact me at 279-5577. cc:E.Yould,APA Distribution List Don NcKay U.S.Fish and Wildlife Service 733 w.4th,Suite 101 .Anchorage,AK 99501 Torn Trent Alaska Dept.of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Al Carson A~aska Dept.of Natur<1l Resources 323 E.4th Avenue Anchorage,AK 99501 John Rego Bureau of Land ~illnagement Anchorage District OEfice 4700E.72ndAvenue Anchorage,AK 99502 Bob Lamke U.S.Geological Survey \~a ter Resources 733 \-lest 4 th Avenue,Suite 11 00 Anchorage,AI\.99501 Bill \Yilson or Chuck Evans Arctic Environmental Information and Data Center (U of AK) 707 "A"Street Anchorage,AK 99501 Susitna Hydro Electric 4 September 4,1980 Dave Sturdevant Department of Environmental Conservation Pouch "a" Juneau,AK 99811 Larry Wright or Bill (velch Heritage Conservation and Recreation Service 1011 East Tudor Road,Suite 297 Anchorage,AK 99503 Brad Smith or Ron Horris Na tional Harine Fishe ries Service 701 "c"Street,Box 43 Anchorage,AK 99513 .- C!"nt-:l)","¥"n.In~o.L"I'i.....u~r.~u,.to.' Susitna Hydro St-~Ccmnittee clo A1Carsm ~ka DepDJ:tuent of r~at:ur<ll Baaourccs 313 East 4th Aven.ua hlchorage,lUaska 9~501 D&.r Al: Last '(.reek we fon~chd to you for di.-;trlbuti.o:l to the Susitna ~lydro Stezrl.ng Cc:~::ruittee.copies of tr2 envirOl."!!!"altal pmce~nmluals applicsble to POS Task 7,as prepared by Terrestrial E.~"it1.:ronr.ent31 Spec;81 i .,ts,L~.~).These ~:muals should DnSt~maT]of the qtr.:!sticns releting to the details of aut'Plan of Study.~.:r.:.!'t-.'Otlld appr<1ciata it 1f }"CfJr cc.cmi.ttee would re"llie;'1 and camxmt on these rnnuals at its earliest co:~-enLr.>TlCe.He.,-0.11 then p~pa:re 't\rltt:en responses to tiny ea:t::Xmts re- ceived.If:in fcllaving thb process t:L'wre ara still cutstanding qucsti.or'.s that l."Cquire detailed tec..l-uUcal responses,'t-Je ":7il1 be pleased to have the ~prcprlate prir.ci.pD.1 :t..'1Vesti.gators nrika n pres(~ntati.cn to your ccr!flrl.ttee. T.E.S.'Y.."ishesto rr.:d.ntain positiv~cant:rol rn,"&the.'1c ~.arn.trlls,and \;C 't~uld like to faci.li.tJte tr.at wish.n~e.ttac.~cd forms might b~Uge- ful to you t:ot-mrds that goal. 1'rusdng this procfV~Jre rceets with your appl:OVll1. Sincerely, FO:t TIlE EXr:.OJITVE DIRECTOR Fobert A.l'nhn Director of E::Jgi.~ecring cc:J.Lm~en~ J.Gill E..'1closurcs :.~Gt:ated D'W',et (x)NQJR: EPY: TJM: TJ.v: SUB TASK 7.05 ALASKA POWER AUTHORITY RECORD OF RECEIPT OF ENVIRONMENTAL PROCEDURE MANUALS COPIES ASSIGNED TO ___ TITLE Socioeconomic Analysis COpy # 7.06 Cultural Resources Investigation . 7..07 Land Use Analysis . 7.08 Recreation Planning ...•........................... 7.10 Fish Ecology -Jmpact Assessment and Mitigation . 7 .11 Wi1 dl ife Ecology -Fu rbearers . 7.11 Wildlife Ecology -Big Game Impact Assessment and Mitigation . 7.11 Wildlife Ecology -Birds and Non-Game Mammals ..... 7.12 Plant Ecology •.................................... 7.14 Access Road Analysis ....................,. SUSITNA STEERING COMMITTEE COPY #REcrpIENT SUB- TASK TITLE Record Of Distributio~Of Environme~tal Procedure Manuals COpy 1/RECIPIErn i /L !i 1~2:",:~:....1,'_ IIt;;.I ~,t-="Z.=-~;...'+1 _ j.LZ.J------_---l1\I~--------- 1/6 I "i-~.?...;;.<"'"_+i---------~//!I 12 (;>I------+~_+--------------'--+I --------t-,~~------- I?~~/~../;~l::;"~~'~""A·~'_41 ~ -... J5 socro-/0 7.11 WILDLI FE /1 ECONOl~IC Il ECOLOGY IZ,ANALYSIS -FURB EARERS 13 11 /4-14- /(,I)r 1<1 II? /9 /9 2/2/' 2"-Zz. )5 CULTURAL if 7.11'WILDLIFE q ilESOURCES /(;)ECOLOGY -/0INVESTI-BIG GAME GATIONS 12.IMPACT /'V . 14-ASSESSMENT /3 I~ AND MITI- GATION Ir' If.:.PLANNING Ie.. /'7 17 /8 /& /9 19 ']7 LAND USE /0 7.Il WILDLI FE 1/ ANALYSIS /1 ECOLOGY -/2-BIRDS AND /l..NON-GAME /4- /<i-MAMMALS ~Ie:. 11 18 ;9 /9 21 21 2Z Z~ RECREATIOIl /0 1 /3)8 7.12 PLANT PLANNING /,ECOLOGY ;4- 13 If' /4-Ie. I~1'7 f Ie;/9 /1 ZI !lid 23 Zz,241 ~o FI~H E-COL-1/7.14 P.CCESS /)" Or.,lHP:;CT jz,I ROAD Ie..ASSESSMENT l AtfALYS~S /9AND/3 j IM!TIGATIlm ~-I !,PLAN;>;ING I t.-,,, J .. 'K TITLE .- .... - - Sincerely. I~t .O"'UI_U:1TrR .Olm:PUDLIC ;a umCi£lti'U'lO /)1,1.UnUtlSU.D AGIJiCIES AUD ORGAtUZATlOiiS .On Febrtfiu·,,Y:.j;..~98U:,.i'..~.(de 'Y.Quld.Ey.ecut.ive Direttor of the Ahs~a "ower AUWOrf ~~'.preV"red a 'forwarding let.ter i nt.n}(Juctrtg Ute «1ctelHcd r'lan of'SLud,.V·for tbe Sust-tn~-Hyd("Of:l~c.t.rfc Prcjcct.He fiuted att,he time 1:h~tthe-plan did not.pUl"'IMnentl.}Y fix'tap.m~mllU"in wt\1en: the pJ'Dposed wort(·wotildbe -ltccOlifI'li'sbed anoiexpre~sed his des.1 r('~Uli!t your 3ss1sttmt~Wbuld conb~jbirte to its stec1ldt il!~)ra\'oement. The Pt--oject Team:bas bc.~n heavily engaged duri og the pa~'t.ni nc- lMntb~in acc.ou(J)Hs-ifl"!J ..f.JU!mc.f\V tii51:~~nd ~ubtasks \fMCh to!lt-t.her win uH.i.fJtttciy luad t.o the:basis.Up9il which Un:SUIte-of J1.1 Dska caD INlke an fnfo11Ut;od decision as'~o wbe'ther it Ci'E;l Or stlould f,roC-i!t!'-cwit.h treE Susltnil :. Hydroelectric Pn,jeet._(:on~ltuct.ton of a camp was a:r.npleted in hju11 1980 Dfti.'r-the Wilti'na Oi:lUj's·lOO..Ffeld crews have Qpp.rated·'Since thcnfrom:t.trc Iti'tana Cauil b.nd .f-rom a number of ot.heY"loe(l1.10f(S,Itjlf)ort",nt inftH'rr~tion has bl!an and continUf!."i to be collect.cd.w,:-k.now IiItlch twre now abDut thegeology,hydro logy p 'se1stlJ)loU)'.~nvi ronment...and espec1 ally ahout the coocerns and interests of the public_. :..[vett while the w{)rk'hCiS progt~ss-~d..trle Youldis prokctlc d~ires ::-.~~_I!,PO',,\\~iT.w been realized.I ..number of 1fJ~ortmJt ehang2s have been made to th~ .;','''Q!iiTY phn.1his yolui'ne ducuments the l--e'71sions(tnd briefly describes theh-' :~;is.~n,;A 9t-nesfs.OII~B9~tn•.your careful l"eview and CQm:~nt.~wolild be-\'orJf ::...':,';':(.'..,~mt,rch apprec1ated~I 51nce",ly hope y{;u will tiJkt!thetitne to .,ddt"ess ....,.....u.-t_hmto~.,._,_.,_'_O"i B '.'.. ___UP .'t .:c.-JCt:~.().[M.!t.fhmcy B-1 unck .f Publ1c'PdrtiGip~:l'tion Officer' ,Alil.s"-"POH'f:!r AutflDrjt~f -n !~333 lies t ~th Aventle~Sui te 31 ';...r'JldlDl"'ilge.AliJska !l9501 /~':i _:__:\On bendl f of the ent;re Project learn,f \~ni)t.t.o exru~!j.~OU!~_t\IJPrcch'" _":t.l0n for the $trnng int.et"est you have CXf)r'Cs~·etf Lo d.,te.\h ttl yuur __J.f--C:CasF1stancep U,e t"e\~1s.ed plan waH continue to be A-dynamic document. \,'~~ri41l,"-• .. ;PG :--l .':T'I'----_. ~:L..:-'r., >:-'I"-:-- _~_'__i, I .--,-I-:-'1 _....:_~_.~ .:---- John D.l.al«tnce Pr'Oj c-ct.ManiP'~cr rr!~, If "to"..':r o .',r~\~'\\JA r s.HAMMOND.&OVfRJlO' DIVISION OF RESEARCH 8lDEVELQPMENr November 21,1980 323 E.·1TH A VENUE ANCHORAGE,ALASl<A9950T 279-5577 Eric Yould Executive Director Alaska Power Authority 333 W.4th Avenue,Suite 31 Anchorage,AK 99501 Dear Hr.Yould: r~~(~~iVED .- f""", - - The purpose of this letter is to pravide you with the.Susitna Hydro Steering Committee review comments regarding the procedures manuals which d'escrihe the Task 7 studies being done lmder the contract hetween APA and Acres American.As you know the SusHna Hydro Steering Committee is composed of representatives from state and federal agencies and.the University of Alaska..Function of this commlttee is to provide coordin.ated exchanges of infonnation between APA and the interested resource management agencies. The Steering Committee met with representatives from Acres American and its suhcontractors on July 17 and 18,1980.The purpose of this meeting was to review the environmental studies portion of the contract with Acres American and their subcontractors.It soon hecame apparent that the subcontractors I,ere unable to provide the Steering Committee members with an adequate levei of detail concerning the·scope and me thodology which would be used to carry these s tl.ldies out.The Acres American representative stated that the level of detail that we were looking for would be found in their yet to be published procedures manuals.~-le agreed that it would be appropriate for Acres American to provide copies of these procedures manuals to members of the Steering Committee for their review and comments.The following procedures manuals were provided by Acres American for oui review: Subtask 7.05 Socioeconomic Analysis Sub task 7.06 Cultural Resources Investigation Suhtask 7.07 Land Use Analysis Subtask 7.08 Recreation Planning Eric Yould 2 Nc~mber 21,1980 Subtask 7.10 Fish Ecology Impact Assessment and H1.tlgation Planning Subtask 7.11 Wildlife Ecology (Big Game Impact Assesslf.ent and Mitigation Planning,Fur Bearers,and Birds and Non-Game i-1amTl'.als) Subtask 7.12 Plant Ecology Subtask 7.14 Access Road Analysis The following agencies were provided copies of the procedures manuals and have responded with review comments:Alaska Department of Environmental Conservation,Alaska Department of Fish and Game,Alaska Department of Natural Resources,U.S.Geological Survey,National Marine Fishery Service,Heritage Conservation and Recreation Service,U.S.Fish and Wild Ufe Service,and the Arctic Environmental Information and Data Center.The following.is a synthesis of the comn~nts from these agencies.Appended to this letter are copies of the written comments which were received from those agencies identified above. SUBTASK 7.05 SOCIOECONOMIC ANALYSIS Review of the procedures manuals indicates that "this study may not address the indirect but highly significant impact of construction and operation of the project on residents living in the region.The boom that occurred during the construction of the Trans-Alaska Oil Pipeline (TAPS)gives us an insight into the sorts of impacts that may be expected.For example,traffic congestion,strip development of small communities,stores out of necessary goods and materials because of accelerated demand by construction.In order that the socioeconomic impact studies may be more comprehensive and address these sorts of impac~ts we make the follmving seven recommendations: 1.Local and regional recreational facilities and opportunities should be assessed to determine the ability of those facilities to handle additional users in light of increased demand. 2.The study should address the probability of additional industrialization of the region as a result of power from the project.Then the study needs to assess the impacts and socioecomomic implications of industrialization scenarios that would be driven by this project. 3.The study should address the cost and availability of products and services.This should also address the inflationary impacts that are.ilsually associated with a boom type cyclical expansion such as construction of a project of this magnitude may cause. 4.The study should address the cultural opportunities and how they may be affected in both positive and negative ways by the proposed project. Eric Yould 3 Nt.-"'~mber ,21,1980 5.The study needs to address the implications of the project on a composition of the people who live in the region.An obviouH first step would be to establish baseline survey data in the preconstruction era so that we know ,vhatthe population composition is in this area before construction begins. ..... 6. 7. An assessment of the changes in the sociopolitical structure of the region that could be expected result from the change in the economy as a result of construction an operation and ~ubsequent developments that would be driven by thIs project. The analysis does not address the impactsof.the project on users of fish and wildlife resources.I refer you here specifically to memos included in the Department of Fish and Game revie~\I submittal which indicate that Acres and others deemedt"t inappropriate for the Department of Fish and Game to carry these studIes out. However,in our revie\\I of all the s tud.i.es identlf led above we find that neither Acres American nor any of other.of the sub- contractors have included this important issue In th.eir plan of work.The scope of the analysis does not include any work designed to mitigate the project impacts on fish and wildlife. ..... - SUBTASK 7.06 CULTURAL RESOURCES INVESTIGATION Although this study ~1aS not formatted or laid out in a way similar to the others the review comments indicate that the approach in the scope and methodology proposed.is appropriate and sufficient fnr the task at hand. SUBTASK 7.07 LAND USE fu~ALYSIS The follovling comments were made: 1.The scope of the land use analysis needs to be expanded so that the downstream impacts all the way to salt water are adequately addressed.As an example of a dO\\IUstream impact which is not included but needs to be addressed Is the is sue of navigab Hi ty on the Susitna River below the proposed dam • 2.There is no apparent linkage or coordination between the land use analysis and the socioeconomic and recreational studies. 3.APA should seriously reconsider the decision that has been made to delay future land use analysis.The contractors state that data from other disciplines may be needed to "fine tune"this study.However,we can assume most of these values or issues and get on with one of the most critical studies that could provide data to be used in making the decision as to whether Susitna should be built or not.It is recommended that APA consider the use of-scenarios to describe future land use with and without the project. Eric Yould 4 NL~mber 21,1980 A recommended way to begin addressing dotoi'nstream impacts is to become informed about the work currently heing done in thLs area by local,state,and federal ':lgencles.ThIs wilJ.help to elLminate any dup Hcation of work.Once APA Ls m.,.qre of 1.11<1 t studies . agencies ,have done the APA contractors can be tasked to synthesize the existing studies and complete only additional studL:s needed to complete the scenarios. SUBTASK 7.08 RECREATION PLANNING 1.Scope of the recreation planning appears to be incomplete.The total thrust of the study appears to focus on recreational opportunities in the impoundment area with the obvious underlying assumption that Susitna Dam will be built.~lat is absent Ls any sort of assessment of the proposed project lmpacts on exLsting recreation navigation and land use in the river valley above,within,and below the proposed project.There Ls no question that we have to carefully plan for reservoir recre~tion development assuming there is a project.It is also obvious that the compelling need that needs to be met today is a valid and accurate determination of existing recreational values so that this decision can be factored into the ultimate decision as to whether Susitna should be built or not.An equally important result '</Quid be Identification of those values for mitigation which will be requIred if the project is huilt. 2.This study needs to include a documentation of the flowing water resources and uses that ,~ould be impacted by the project. 3.This study needs to document the existing upstream uses of Susitna. SUBTASK 7.10 FISH ECOLOGY IMPACT ASSESS~ffiNT fu~D KITIGATION PL&~NING 1.It is acknowledged that none of the reviewers had a comprehensive picture of how this task will be carried out.The reason is the Department of Fish and Game will be actually doing much of this work as a subcontractor to Acres American and has not had the staff or the resources necessary to put together its procedures manual for this facet of the work.The comments given below should be qualified with acknowledgement of this fact. 2.The contractors need to broaden their scope of mitigation concepts tha are included in the studies.There are other options availahle for mLtigation planning above and heyond wh.:tt is included in the procedures manual as it Is nm.~rritten.I refer you to the detailed comments made by ADF&G. 3.We recommend that an assessment of effectiveness of mitigation used on other projects to reduce impacts also be studIed before we determine what sorts of mitigation techniques will be applied to the proposed Susitna project.The reason for recommending this is to enhance the pr'obability that the mitigation ~....e apply to the Susitna project will be successful. Eric Yould 5 N'c.~mber 21,1980 4.Table 2 should be amended to identify the issue of the effect of the project on rearing.fish passage and egg I.ncubation in the Susitna River from its mouth upstream to the proposed dam site. ..... 5.The mitigation alternatives should include a cost benefit analysis in phase 2• - 6.There is a lack of adequate particIpation by resource management agencies in the impact assessment or mit igation planning as proposed in this procedures manual. 7.TIle water quality subtask within thIs study needs further review regarding the extent of data required and details about timing of the data collection. SUBTASK 7.11 WILDLIFE ECOLOGY A.Big Game Assessment and Mitigation Planning 1.This study does not describe the methodology that \01111 be used for assessing impacts to be mitigated.The procedures manual discussion of formation of a mitigation team and a series of meetings and conferences as a methodology is inadequate. 2.The scope of mitigation concepts needs to be broadened in this study.The National Environmental Policy Act (NEPA) defines mitigation in five different ways: a.Avoiding impact all together by not taking a certain action of parts ~f an action. b.Minimizing impacts by Hml ting the degree or magnitude of the action and its implementation. c.Rectif iying the impact by repairing,rehabilitating,or restoring the effected environment. -d.Reducing or limiting ,the impact over time by preservation and maintenance operations during the life of the action. -! - e..Compensating for the impact hy replacing or providing substitute resources for environments. Since the Sustina project will be subject to an environmental impact statement the Alaska Power Authority should assure that the contractors preparing the application adequately address all aspects of mitigation in order that the submittal will be adequate fo,;r theE.I.S. Eric you1d B~Wildlife Ecology -Fur Bearers 6 N(J:'~mbe.r 21,1980 1.Scope of these studies needs to be extended to salt water. The reason is the proposed Sus.i.tna hydropower project will have impacts all the way to salt water. 2.This manual does not acknowledge the need for mitigation for these living resources.It is recommended that the procedures manual be revised to reflect the need for mIt igation for fur bearers. 3.The manual describes surveys which will he done only in the winter.The seasonality of this approach will result in certain data biases and lack of data for the intervening months. 4.The studies state that radio collaring of animals will be done.Hmv will the radio collar data be Ilsed? c.Wildlife Ecology -Birds and Non-game Hammals 1.The scope of these studIes needs to exteuo to satt water. 2.The procedures manual fails to acknowledge the need for mltigation of birds and non-game animals.It is recommended that the procedures manuals be revised to reflect this need. General comments on wildlife ecology procedures manuals. There is a compelling need to integrate the wildlife and the plant ecology studies so that the end results are meaningful and useful to the decisions which will be made.Each of these study elements should apply appropriate quantitative methodologies to evaluate animal habitats.The methodology used may depend on the characteristics of the species or group of specIes they are d~aling with.~.Jhatever method is adopted,it must be biologically justifiable and provide a relative estimate of the habitat value per area unit for the study area. SUBTASK 7.12 PLANT ECOLOGY 1.The scope of these studIes needs to be expanded from the dam site all the way to salt water.The reason for this Is that construction and operation of the dnm will impact vegetation to that extent. 2.TIlere needs to be a high level of integration and coordination between the plant ecology,hydrology,and the wildlife impact assessment studies.This is because a great part of the wildlife impact mitigation will be based on vegetation. Eric Yould 7 NL~mber 21.1980 3.The definition of wetlands used for classifying habItats should be compatible with data already collected in the Susltna Basin by the cooperative study unden-lay wi tIl DNR,ADF&G.and SCS.I';e recommend that the classification system developed by the U.S. Fish and Wildlife Service and described in "Classification of \-1etlands and Deep Water Habitats of the United States"(F~>lS/OBS79/31) be considered as the wetland classification for these studies. ..... - - SUBTASK 7.14 ACCESS ROAD ANALYSIS 1.The analysis of alternatives does not indicate whether stream crossings will be reviewed to determine extent of icing and adverse environmental impact as a result of crossing these streams. Stream crossing and structures should be designed to avoid creating icing and erosion problems. 2.This analysis should include assessing the effects of an increase in fishing due to newly opened road access as part of its scope of work • 3.There is an obvious linkage between access roads for this project and land use/fish and wildlife studies.Review of the manuals does not indicate that the appropriate process 0["mechanism is in place to see that this occurs.. GENERAL COMMENTS It is the consensus of the Steering Committee that each study task procedures manual should include two maps: 1.A map that delineates the boundaries of the specific study tasks described in the respective manual. 2.A second map delineating the overall study area.ie from the mouth of the Susitna River to the Denali Highway. SUHHARY In conclusion,the above comments should be considered as summary comments designed to flag the most significant and compelling issues which require correction or rectification in order to assure that the procedures and approaches used in the studies will yield the answers necessary to make the most infonned and best decision regarding the proposedSusitna project.The Steering Committee members believe the most compelling need is for a well-conceived process to improve the linkage and·coordination of the various studies •.This is particularly true in several of these studies where one element Is dependent upon fIndings of other studies.·An example is the need for fisheries impact mitigation to be built upon the assessment of the existing fishery resources and the instream flow/hydrology studies.TIle recognition of the sequential nature of this process is lacking in the procedures manuals reviewed. Eric Yould 8 N~mbern.t9-&e He also ~.ould like to emphasize the importance of the relationship between the ultimate design of the procedural manuals and a particular study product;that product being identification of and development of mitigation measures for the human and natural resources being studied. We have recommended several times above that mitigation be added or broadened in scope on a resource by resource basis.This concern is based on our collective experience in assessing the adequacy of the mitigative features of countless environmental statements;they are often very weak in this critical area.As the mitigation efforts may be a key to assessing the feasibility of this project and a key to the success of the environmental statement that may folIm."we urge you to integrate "mitigation"into all systems designed to assess human and natural resource impacts. Sincerely, ru~ Al Carson Chairman Susitna Hydro Steering Committee cc:Steering Committee Members Reed Stoops .- M EMORAt\J'bUM TO SUSITNA HYDRO ELECTRIC STEERING COMMITTEE MEMBERS . (See Distribution List) QL FROM AL CARSON Steering Committee Chairman Statlof Alaska DEPARH1ENT OF NATURAL RESOURCES DIVISION OF RESEARCH &DEVELOPMENT DATE:October 29,1980 FiLE NO. TfLEPHor,E ~IO: SUBJECT November 5 ~1980 Meeting .- I~ There will be a meeting of the Steering Committee at 8:30A.M.on vJednesday. November'5,1980 at the University of Alaska Anchorage Campus Center Executive Conference Room.The Campus Center is located approximately 3 blocks east of the corner of 36th Avenue and Lake Otis off Providence. Attached is a sketch showing the location of the conference room on the lower level. T~put'pose of this meeting is: (1)To finalize Steering Committee review comments on the procedures manuals used by ACRES and their contractors. (2)To comment upon ACRES approach to identification of power alternatives in the railbelt.Attached please find a packet of information for your review before the meeting. (3)To identify any other tasks or actions that the members of the steering committee wish . The 8:30 A.;~.to Noon session will be devoted to items 1 and 3.The 1:00' to 5:00 P .t11.session will address i tern 2. Please give this meeting your highest priority for 11/5/80.Your partic- ipation is vital if our effort is to be successful. DISTRIBUTION LIST ....Don McKay U.S.Fish &Wildlife Service 733 W.4thAve.,Suite 101 Anchorage,Alaska 99501 . Tom Trent AK Dept.of Fish &Game 333 Raspberry Road Anchorage~Alaska 99502 John·Rcgo Bureau of Land Management Anchorage District 9ffice 4700 E.72nd Avenue Anchorage,Alaska 99502 02-0CI·:qRev.10t791 OCT 30 1980 ;~POWEk AUlhUJdfV . SUSITNA HYDRO ELECTRIC STEERING COMMITTEE MEMBERS DISTRIBUTION LIST CONTINUED Bob Lamke U.S.Geological Survey Water Resources 733 W.4th Ave.,Suite 400 Anchorage.Alaska 99501 Bill Wilson Dr Chuck Evans Arctic Environmental Information and Data Center (U of A) 707 IIA II Street Anchorage.Alaska 99501 Dave Sturdevant Dept.of Environmental Conservation Pouch 110" Juneau,Alaska 99811 Larry Wright or 8ill Welch Heritage Conservation and Recreation Service 1011 E.Tudor Road.Suite 297 Anchorage.Alaska 99503 Brad Smith or Ron Morris National Marine Fisheries Service 701 IIC lI Street,Box 43 Anchorage,Alaska 99513 Attachments bcc:R.Stoops -R&D D.Wozniak -A.P.A. October 29,1980 Page 2 •I'"e;"A.·POWE.l'{Ai:.itHOR1TV~:...""'1:1.#.~~~."-."•.'..'.• \\ &LA Bt...ft1 v'S Ft,..);;. N.M 1-~ /j(J~ A 1Z fJ)c I' :;"7.9 -yo 5 2.-J ~l 11 ."1.y 1 ',- .Yk!-9&~/ B'ft{-'1661 '2."7-(-sooG :a7b-~~~g, /...1'1 ~~fhA-~J C.""m:,~ III 5/80 ~l(AA tbJ~~q ,~n ;"1.~~.. .271-1/38 (/5GS-/fnekr 46~-2..6'~~.ADK -3"Nu J.'?-l~"./I e-Rs ___.8'ot /r;..mkc .5o Daue.Sf-e;.KcM..va.nf .LPrA~r W~i6HT -.J 1-t'V'I I U 0Yv-.~ .)If KL t4 ..sTE-1Z1/J p~~CCl~Y ;7to ....,./:.;.;".,.,......~,...//rL-.//l,_//.,-..,_...'.""...~. .- DA'-'If:>b W0 -'2JtJ I Ale ,6Y'(//£I;::7Jr'lJdX'D .~/.S~4'/JtE/Ar 9 fl-J .'LL/4/t;T- (!hlf.f.s IePt-{f:..R,E s TC ~ A(c..C\(\so~ .2;G -7(/&(APA 2-7)-7t.l2.-./1 »/I ..1'/f -()S 'II A OFrJ.tf!- D ,{/J..-..177-3~2 (frL.C 3'("1..1 -OS£/(AlJF'f-6 . ).1 C{-~S.,1 ~f)J\t f\ ALASKA POWER AUTHORITY r-lovember 26.1930 Mr.John Lawrence Attn:Kevin Young Acres ~~~rican,Inc. 900 liberty Bank Building Nain @Court Buffalo~rle~-'I York 14202 Dear Kevin: Attached 1s the finished version of the Susitna Hydroelectric Steering Com- mittee findings to the Task 7 Procedures f4anuals.A working draft was presented to us during the November 5.1980 meeting;this version incorporates comments made at that meeting.AS you will see,it differs from that ~rorking draft in minor detail only.Also attached are agency source documents,resources previously un- available to us. As I sunmar1 zed to the Steeri"9 Coomi ttee at the flovcmber 5 meeti ng.the POltier Author;ty considers the majority of the comments to be reasonabl e.hel p- ful t and worthy of immediate incorporation.He accordingly solicit your posi- tive approach to accOffimOdation of the Steering committee comments and reccmmend- ations. I suggest we very quickly address the acceptable recommendations and then move on to focus our energies on those that require detailed evaluation.To insure \'/e are in agreement,I suggest you advise us on a point by point basis those comments you rccanrr~nd accepting,with"narrat1ve as to method of incorporation.In separate correspondence.advise us of those camtents for which you have reservations,and your reco.'I1iP.endations thereto.In view of the fact that He have been privy to the Steering Cornmlittee thinking since early November.you should be able to do this ~tell before the Christmas Holidays.Such a timetable \'1111 hopefully facilitate early resolution of all the comments 1n time for a report to the Steering Commit- tee at their next convening. Sincerely, FOR THE EXECUTIVE DIRECTOR David ~!ozniak Project Engineer F- Attachnrent:As noted CONCUR cc:J.Haydel..Acres Buffalo wlo attachment RAM J.Gill~Acres,Anchorage,wlo attachment A.Carson.Department of Natural Resources ~Anchorage.'1110 attachment l~ark Robinson,FERC.825 N.CapitO]St.,NE.Washington,D.C.20426 MFR:Next convening tentatively scheduled for Februrary,1981. - - ALASKA PO\~ER AUTHOR lTV f~ovember 26,1980 f.1r.Alearson State of Alaska Department of Natural Resources 323 E.4th Avenue Anchorage t Alaska 99501 Dear AI: Thank you for your efforts in pulling together the Susitna Hydroelectric Steering Committee review of the Task ,7 Procedures Manuals.I have formally forwarded"'he CClflii'.ents to Acres I\mer1can t Inc.,with instructions to act prompt- lyon the h~cOltl1lendations.1 anticipate the vast majority 1f/111 be considered by the end of the year,with the remainder addressed shortly thereafter..I am planning on giving a report on their dfsposition at the next convening of the committee.which 1 am assuming will be in February,1981. Once again,thanks to you and your comn1ttee members. Sincerely. FOR THE EXECUTIVE DIRECTOR David t~ozniak Project Engineer - cc:Don HcKay U.S.Fish &Wildlife Serviee 733 W.4th Ave ••Suite 101 Anchorage t Alaska 99501 Tom Trent Alaska Department of Fish &Game 333 Raspberry Road Anchorage~Alaska 99502 John Rego Bureau of land Management Anchorage District Office 4700 E.72nd Avenue Anchorage,Alaska 99502 Bob Lamke U.S.Geological Survey liater Resources 733 W.4th Ave ••Suite 400 Anchorage.Alaska 99501 Bill Wilson or Chuck Evans Arctic Environmental Information and Data Center (U of A) 707 MAli Street Anchorage.Alaska 99501 CONCUR RAM Nr.Al Carson November 26,1980 Page 2 Dave Sturdevant Oepartme~t of Environmental ConserJat1on Pouch no" Juneau,Alaska 99811 larry Wright or Bill Belch Heritage Conservation and Recreation Service 1011 E.Tudor Road,Suit~297 Anchorage~Alaska 99503 Urad Smith or non norris National Marine Fisheries Studies 701 "C"Street,Box 43 Anchorag~,Alaska 99513 ,~ ALASKA POtIER AUTHORITY Harch 25,1981 Hr.A1 Carson Chainnan,Susitna liydro Steering Committee A1ash Department of f~atura1 Resources 323 East 4th Avenue Anchorage ~Al as.ka 99501 . Dear !1r.Carson: I regret that it has taken so long to react to the Steering Committee's suggestions on improving the Susitna hydroelectric project environmental plan of study.It took a number of I!!Qnths for Acres and its subcontractors to de- velop and transmit their set of responses and plan of.action.The Power Authority received that transmittal on March 2;1981.We have not been able to make any final decisions on scope changes.however,for hiO reasons.First. Acres.has not yet provided the program modification suggestions ioany detail of scope or cost.Secondly,the Power Authority has had to ,~a1t for other program components (such as Tasks 4 and 5)to be evaluated for necessary scope changes.It is only in revi(!Wing the ent1reffrst year program that we can identify a~for improvement,assess their cost impact.evaluate their rela- tive merit andestab11shed priorities among the myriad competing needs. The Power Authority win have prepared its set of recommended scope changes and resultant supplementary budget request by April 3~1981.It remains to be seen whether all,none or a portion of the supplemental funds will be forthcom- ing. I have requested previously that you organize a Ste~ring Committee meeting for eitller April 13.14,or 15.At this meeting,we ~111 present our proposed program lroo1ffcat1ons.which I trust you wi 11 find go a long way toward satisfy- ing the Coum1ttee's concerns.In preparation for that meeting.I have a.ttached a copy of the Acres response to the Steering Comnfttee comnents.The detal1ed re- caThT.~ndatlons.while not contained in the attachment.will be presented at the Steering Cmnm1ttee meeting. S1ncerely~ FOR THE EXECUTIVE DIRECTOR Robert A.Hohn D1rect~r of Engineering Attac~~nt:As stated cc:Susitna Hydro Steering C0ImI1ttee r1ember·s with attachment 1) 2) 3) In response to the Susitna Hydro Steering Committee's review of the TES pro- cedure manuals we submit the following: Introduction We appreciate the time and effort expended by all the members of the Steering Committee in their review of our procedure manuals.In general our responses are dTrect ec1 towards each of the sped fi c comments as presented in the sythes.is prepared by t·1r.Al Carson.Comments presented in the introduction and conclusion are addressed first p..s appropriate our response to some comments are combined to present a clarification regarding subtaskinteractions. General Comments I}In defense of our subcontractors it was nat our understandinQ that the purpose of July 17,1980 meeting·was·to review the environmental studies but rather to compare the requi rements of FERC to other federal and state government permitting agencies.In this context an overview of our environmental program was pr.esented.~Je concur that·in some of the more controversial areas i.e.socioeconomics.adequate study details were not avanable.. The.offer was then extended,and agreed to by the Steering Committee.that procedure manuals be made available for review. 2)As the Steering Conimittee have stated "the most compelling need is for a \'1ell-conceived process to improve 1 inkage and coordination of the ·various studies."tole concur that this is e!:sential and have expended considel'able effort in this direction.Some misunderstanding may have precipitated from the review of the procedure manuals as these manuals were prepared as practical subtask -specific documents designed for (1)exchange of program design details (2)control of adhei'ence to the study program (3)and assurance of continuity in the event of changes in oroject per- sonne 1. Our coordination efforts will concentrate on the following areas: interaction among study participants infonna.l interaction with government agenci es to acqui re insi ght into concerns and general policies . formal interaction with government agencies to allow input and revie''1of study design,development selection.project design and mitigation planning 4)"interaction \"ith the public in the form of information supply and input into the decision making process Documentation of coordination to date will be included in the environmental annual reports to be available in April 1981.In addition we have requested TES.to prepare an outline of their coordination process which will be supple- mented by Acres and supplied to the Steering Committee for review if desired. 1 - ~, 3)An area of primary concern appears to be the extent of effort di rected towards studying the Lower Susitna Bas in bet;'/een Ta lkeetnaand Cook Inlet during the Phase I period. Our approach to date as outlined under Subtask 3.10 of OUT POS is ~to estimate the flow regime,sediment regime and morphological characteristics .of the lower Susitna River under natural conditions and (prepare)a preliminary determination of morphological impacts which could result from flow regulation and sediment trapping at the Susitna Project." ~A preliminary evaluation of the .potential morphological changes,and impact on the river cha·racteristics due to flow regulation will be made during the early part of 1981.If considered necessary at this stage"an expanded field data collection and study·proqram aimed at evaluating impacts in more ..cii!.tai1w91l be developed in conjunction with the DNR and presented for consideration to APA.~ It is our opinion that the results of this study are necessary before the ~rits of any detailed downstream studies can be fully assessed. It is obvious that we require a more comprehensive understandinIJ of the resource agencies concerns,the reasons for these concerns and the study approach they would like us to adopt.To facilitate this TES during the rm:tnth of March 19B1 will contact the respective agencies directly,to dl scus~.these'.and any other concerns that may ex i st. 7.05 Socioeconomic Although major projects like the Trans-Alaska Oil Pipeline provide justification for the need of adequate preproject soicoeconomic analysis,care must be taken in making direct comparison as to the types of impacts associated \oj'ith a large central ized project such as Susitna vs a transi ent type constructi on associ ated with a pipeline.Susitna should produce a relatively self contained,controlled, centralized work camp established for a 10 -15 year period.For this reason a first step in our socioeconomic program,through a review of other similar type projects,is to identify the most probable types of impacts to be antic- ipated.Our studies will then concentrate on the~e areas of most probable impact. We have.hOWEver,for some time been considering the need to advance some of the Phase II socioeconomic studies into Phase I.The extent of changes in scope and timing of our studies will be discussed in more detail with the Steering Corrctittee and FERC fO'llowing their review of these responses. To present a .clarification as to the comprehensiveness of our socioeconcimic program a listing of categories and variables being incorporated into our socioeconomic profiles is attached (Exhibit 1).This listing is refered to in our response to the seven Steering Committee comments. Coment 1: Local and regional recreational facilities and opportunities should be assessed to determine-the ability of those facilities to hand·le additional users in light of increased demand. Response: Recreational facilities will be addressed on two fronts within the context of the Socioeconomic Analysis during Phase!.\'{ork Package 2 entails development of a detailed socioeconomic profile,the methodology for which is described on pages 7-10 in the Procedures Manual. "...The profiles will include ...public facilities,availability •. adequacy,and cost ...".This includes public recreation facilities.To the extent applicable in Phase I,this analysis will address the "ability of those facilities"at local and regional levels to handle additional users"as suggested by tlie Steering Committee. Additi~ally~we have become aware of a special study currently underway ·by t~at-~u Borough,the resul.ts of which will be considered as an aid in 'our analysis.Recreational categories and variables to be investigated are shown in Section VIU Exhibit 1. Cormnent 2: The studY'should add.ress.the probability of additional indu~trialization of the region as a result of power from the project.Then the study needs to assess the impacts and socioeconomic implications of indus- trialization scenarios th~t would be driven by this project. 3 - - Response: In our eva luati on of the economic base we wi 11 be deve roping a profile of tre-major basic industry components.(Exhibit I section V)~le \'ti'11 review potential .incenti.ves for industrial develQpment created by stable energy'availability and assess the socioeconomic implications of having these incentives materialize. Comment 3: The study should address the cost and availability of products and services.This should also address the inflationary impacts that are .usually associ ated wi·th a boom typecycHc.al expansi on such as con- struction of a project of this magnitude may cause. Response; The availability of products will be addressed under the headings of wholesale trade,retail trade,services etc.as indicated in Exhibit 1 section V.The·cost and relationship of cost to income wi 1.1 be addressed through our assessment of the Consumer Price Index,in'come and employment patterns (Exhibit I section VI).. Coament 4: The study should address the cultural opportunities and how they may be affected in both positive and negative ways by the proposed project. Response: Our present study addresses cultural opportunities under the categories of: H Conmunity organizations,social interaction,enterta;nment etc.(Exhibit I section II). 2)Public services -parks,recreation,libraries,education. (Exhibit I section IV) 3)Recreation -Exhibit r section IV} We do appreciate,however,through your comments and comments from the general public that cultural aspects,especially at the local level,are not being fully addressed ...We at"e preparing the deta i1 s of a program to respond to thi sand will present it to the Steering Committee anoutl ine of our scope as sOOn as it is available. Comment 5: The study needs to address the implications of the project on a com- position of the people who,live in the region.An obvious first step WQuld be to establish baseline survey data in the preconstruction era so that we know what the population composition is in 'this area before construction begins. 4 (c) (d) (a) (b) Response: As stated in the procedure manual.a purpose of Phase I socioeconomic studies is to Uidentify and describe the existing socioeconomic conditions and to determine which are most likely to be impacted by the Susitna Hydroelectric Project u •Sections I and II of Exhibit I identify the categories for which secondary data on the composition of the people who 1i ve in the regi on wi 11 be co 11 ected.The adequacy of th is·da ta bas e· will be reviewed prior to making any decisions regarding program modi- fications. Conr.tent 6: An assessment of the changes in the sociopolitfcalstructure of the'region that could be expected (to)result from the change in the economy as a· result of construction ••.(and)operation and subsequent developments that would....be driven by this project. Response: Our study ,efforts are directed towards an assessment of the socioeconomic changes that could result from the project.In this context we will be assessing impacts on local governr.tent services,revenues and expenditures. In our opi ni on t.however,an assessment as to changes in the soci opo 11 ti ca 1 structure of the region resulting from these socioeconomic changes would be very speculative,not cost effective and 'beyond the requirements for a license application.. Conment 7: The analysis does not address the impacts of the project on users of fi sh and wi ldi ;fe resources. I refer you here specifically to memos included in the Department of FisnandGame review submittal which indicate that Acres and others· deemed it inappropriate for the Department of Fish and Game to carry these studies out.. However,in our review of all the studies identified above we find ·that neither Acres American nor any of other of (sic)the subcontractors have included this important issue in their plan of \·/ork. The scope of the analysis does not include any work designed to mitigate the project impacts an fish and wildlife. Response: (1)Due to the sequential nature of our studies the analysis of the impacts of the project on users of fish and wi ldlife resources cannot beaccom- plished until the impacts on the resources themselves have been ldentified. As indicated in the procedure manual,work packages 8 and 9 dealing with these topics will be performed in detail during Phase II. (2)\~e did deem it inappropriate that AOF&G,cr any other permitting agency conduct the impact assessment and mitigation planning components of our study.To do otherwise.would have compromised the legitimacy of agency objectivity during license review.However under all the components of our study we intend to provide a format for review and consideration of all potential concerns from appropriate State and Federal agencies 5 r=> I - {3}Refer to response 1. (4)Fish and wi.ldlife mitigation is not considered as a socioeconomic com- ponentof our study but is addressed in detail under Subtasks 7:10 and 7:11 as indicated in the procedure manua 1s. Subtask 7.06 Cultural Resources Investigation Comment: Although this study was not formatted or laid out in a 't/ay similar to the others the review comments indicate that the approach in the scope and methodology proposed is appropriate and sufficient for the task at hand. Response: No corrmen t. Subtask 7.07 Land Use Analysis Comnent 1:. (a)The scope of the land use analysis needs to be expanded so that the downstream impacts all the way to salt water are adequately addressed. (b)As an example of a downstream impact which is not included but needs to be addressed is the issue of navigability on the Susitna River below the proposed dam. Response: (a) (b) As stated in our procedure manual our study area for land use is con- centrated in the Upper Susitna Basin and extends downstream as far as Gold Creek.In our opinion the majority of land use impacts directly related to a Susitna development will occur in this area.Certain land use components outside this study area are being addressed as part of our socioeconomic,fisheries and wildlife studies. As you are aware concern has been raised regarding recreational navigation, and riverine based recreational/1and use activities in the section of the river between Talkeetna and Cook Inlet.We are in the process of assessing these concerns and foresee the possibility ~~an extension to our fi sheries and hydrology studies a program to identi fy:1)access to the river by water,air and land and 2)movement within the river itself.Any such study wou]d provide input into the land use,recreation, socioeconomic and fisil/wildlife··resource utilization .components of our study.The details-6{any such _program modificat;onWT1l be submitted to the Steering committee for review as soon as available. Comment,2: There'-'is no apparent linkage or coordination between the land use analyslS and the socioeconomic and recreational studies. 6 Response: There is a definite linkage and coordination between land use,socio- economic,recreation,hydrology,and fish and wildlife components of our study.Although this coordination exists at the study team level it is '-bvi ous that alack of communi cati on does ex;st between the study team and the resource agencies. Throughout the remainder of the Susitna studies we will be exerting considerable effort to bridge this gap and will be soliciting your advice on means of 'establishing efficient avenues of communication, Comment 3: APA should seriously'reconsider the decision that has been made to delay future land use analysis.The contractors state that data from other disciplines may be needed to "fine tune"this study.However, we can assume most of these values or issues and get on with one of the most cri·tical studies that could provide data to be used in mak{ng the decision as to whether Susitna should be built or not.It is recoll1ll~nded that APA consider the use of scenarios to describe future land use with anrl without the'project.A recommended way to begi~addressing down- stream impacts is to become informed about the work currently being done in this area by local,state,and federal agencies.This will help to eliminate any duplication of work.Once APA is aware of what stUdies agencies have done the·APA contractors can be tasked to synethesize the existing ~tudies and complete only additicnal studies needed to complete the s cenari as. Response: We accept the Steering Committee 's recommendati on that we revi ew and synthesize the information available from existing studies being con- ducted by local.state and federal agencies.This has been accomplished to some extent by our socioeconomic,land use and recreation consultants however.we will ensure,through additional contact,that all available information has been acquired.Once obtained we will assess the applica- bility of these studies to the Susitna Project.incorporate the infor- mation into our studies as appropriate and determine if additional studies during Phase II are required. We do"however.identify the need for a recognition of the differences in'objectives and scope between a Susitna Project Environmental Assess- ment study and studi es conducted by agenci es under the;r mandate of' overall Susitna Basin Resource Management, Subtask 7.08 Recreation Planning Corrments: 1.Scope of the recreation planning appears to be incomplete.The tota thrust of the study appears to focus on recreational opportunit'jes' 'the impoundment area with the obvious underlying assumption that Sus i~n~ 7 r- ! F', Dam will be built.What is absent is any sort of assessment of the proposed project impacts on existing recreation navigation and land use in the river valley above.within.and below the proposed project. There-is no question that we have to carefully plan -for reservoir rec- reation development assuming there is a project.It is also obvious that the compelling need that needs to be met today is a val id and. accurate determination of existing recreational values so that this decision can be factored into the ultimate decision as to whether Susitna should be built or not.An equally import2mt result would be identification of those values for mitigation which will be required if the project is built. 2.This study needs to include a documentation ot the flowing water resources and uses that would be impacted by the project. 3.This study needs to document the existing upstream uses of Susitna. Response; ~~have made a clear distinction between 1).FERC requirements for the development of a recreation plan within the project boundaries and 2}an overall assessment of recreation resources and impacts on these resources. Subtask 7;08 responds.directly to FERC requirements and is directed towards a reservoir recreation plan that would be il!lplemented if a Susitna development is approved.Thus the study focus is an recreational opportunities in the impoundment and surrounding area and does assume that the plan would only be implemented if the Susitna dam is bui It. .o--cR ~--..Rr-:r.-- The assessment of existingArelreation resourcesAand the impacts upon them are addressed under appropriate subtasks.specifically 7:07 - Land Use Analysis and 7;05 Socioeconomic. Subtask 7:10 Fish Ecology Impact Assessment and Mitigation Planning Conment 1: It is acknowledge~that none of the reviewers had a~~omprehensive picture of how this'task will be carried.out.The ~eason is the Department of Fish and Game will be actually doing much of this work as a subcontractor to Acres American and has not haa the staff or the resources necessary to put together its procedures manual for this facet of the work.The comments given below should be qualified with ac- knowledgment of this fact. Response: AOF&G have made substantial progress in their fisheries data collection program.The present emphasis is to establish the basis of their program and to implement the field studies.Follo...ling this,detui1ed procedure manuals will be prepared and should be available for Steering Committee review by April 1981. 8 Corrvnent 2: The contractors need to broaden their scope of mitigation concepts that are included in the studies.There are other options available for mitigation planning above and beyond what is included in the Procedures Manual as it is now written.I refer you to the detailed comments made by AOF&G. Response: We view mitigation planning as a dynamic process and are prepared to consider any additional options available.As a means of obtaining agency~input and review we plan to establish a fisheries mitigation task force similar to that organized under Subtask 7.11. Comment 3: We recommend that an assessment of effectiveness of mitigation used on other projects to reduce impacts also be studied befor~we deter- mine what sorts of mitigation techniques will be applied.to the proposed Sus itna project.The reason for recommending this is to enhance the probability"that the mitigation we apply to the Susitna project will be successful.. Response: The intent of our review and evaluation of ~itigation measures used on other projects is to assess their effectiveness and to determine their applicability to the Sus;tna Project. Corrment 4: Table 2 should be amended to identify the issue of the effect of the project on rearing,fish passage and egg incubation in the Susitna River from its mouth upstream to the proposed dam site. Response: It is our intent to address these issues and Table 2 will be ammended accordingly. Comment 5: .The mP.igation alternatives should include a cost benefit analysis in Phase II. Response: The costs associated with recommended mitigation will be identified in Phase I with actual cost-benefit analysis considered in Phase II. 9 """ .... ~I Conment 6: There is a 1ad of adequate pa rtici pati an by resource management agenci es in the impact assessment or m.itigation planning as proposed in this Procedures Manual. Response: See response to corrment 2. Conment 7: The water qua.1 ity subtask within thi s study needs further review regarding the extent of data required and details about timing of the data collection.- 'Response: R&M Consultants has prepared a Procedures Manual for the water quality program.Review of th is document may prov i de therequ ired deta i1 s about timing and data COllection. S)J-irtask 7.11 Wildlife Ecology A.Big Game Assessment and,Mitigation Planning Comment 1: This study does not describe the methodology that will be used for assessing impacts to be mitigated.The Procedures Manual discussion of formation of a mitigation team and a series of meetings and conferences as a methodology is inadequate. Response: The methodology for impact assessment and mitigation \'#as not developed in detail because it was believed that a mare effective program could be prepared following the collection of data in 1980.Rather than develop more than a general approach,it \.,as considered to be preferable first to gain an understanding of the.re'lative population levels of various'species and also identify critical habitat types.In this manner a detailed approach to 'impact assessment and mitigation will be prepared.based on at least a preliminary understanding of the wild- life/habitat realtionships operativ~in the project area.The Procedures Manual will be amended as soon as approach details are finalized. 10 Conment 2: The scope of mitigation concepts needs to be broadened in this study. The National Environmental Policy Act (NEPAl defines mitigation'in five different ways: a.Avoiding impact all together by not taking a certain action ...(or) Darts of an action~ b.~inimizing impa~ts by limiting the rlegree or magnitude of the action and'its implementation. c.Rectifying the impact by repairing,rehabil itat ing,or res tori ng the ...(affected)environment. d.Reducing or limiting the impact over time by preservation and main- tenance operations during the life of the action. e.Compensating for the impact by replacing or providing substitute resources •..(or)environments. Since the Susitna proj~ct will be subject to an environmental impact statement the.Alaska Power Authority should assure that the contractors preparing the application adequately address all aspects of mitigati~n in order that the submittal will be adequate for the E.I.S. Response: To date we have concentrated our mitigation efforts on approaches a)and b)(avoiding or minimizing impacts)through providing environmental input into development selection and preliminary design.This approach will be expanded to include approaches c,d and e following development selection. 8.\.jildlife Ecology -Furbearers Comment 1: Scope of these studies needs to be extended to salt water.The reason is the proposed Susitna hydropower project will have impacts all the way to salt water. Response: The scope of the furbearer studies that concern aquatic furbearers (e.g.muskrats.beaver,and river otters)have already been extended on a limited basis downstream to the Delta Islands.At the present time there does not appear to be justification for extending the study effort any further downstream.Should the results of Phase I indicate that further extension is in order,it will be proposed for Phase II. Corrment 2: This manual does not acknowledge the need for mitigation for these living resources.It is recommended that the Procedures /~anual be reyjsed to reflect the need for mitigation for furbearers. 11 .... Response: Although mitigation was not mentioned in the Procedures l"4anual,it will certainly be addressed in the furbearer studies.In order to strengthen the interdisciplinary cocrdination concerning mitigation,the Principal Investigator of the furbearer studies has been added to the mitigation task force as described in the Big Game Procedures Manual. Conment 3: The studies state that radio collaring of animals \...i11 be done.How will the radio collar data be used: Response: Radio telemetry data will be used to determine the home range size of key furbearers~This information,in conjunction with the vegetation maps,will enable the generation of an estimate of how many animals the area can normally support.The radio telemetry data are also being used to determine seasonal distribution and habitat util ization of key furbea rers. Note Concerni~g Furbearer Procedures Manual: Since_it was impossible,prior to the initiation of these stUdies, to est~blish specitlc techniques that would be highly effective in sampling the furbearers,~ny of the techniques outlined in the Procedures Manual have been modified following the first field season.An amend- ment to the furbearer manual will be prod~!Ced in spring,1981.and will reflect the refined approach that is now being used. C.Wildlife Ecoloay -Birds and Non-qame Manmals Corrrnent 1: The scop~of these studies needs to extend to salt water. 12 Response: At the present time,bird and non-game mammal studies are being conducted as far downstream as Sherman.With the exception of a bald eagle nest survey,there are no studies planned for this discipline downstream of Talkeetna.Insufficient data exist to support the conclusion that major terrestria1 impacts wil1 take place downstre'am from Talkeetna.At the present time,the expenditure of funds to study birds and non-game mammals in this area does not appear warranted.Should the results of the Phase I hydrology 'studies indicate that major changes in terrestrial habitat are likely to occur,an intensive Phase II program will be imple- mented.' Conment 2: The Procedures Manual fails,to acknowledge the need for mitigation of bi rds and non-game anima 1s.It is reconmended that the Procedures Manuals be revised to reflect this need. Response~ Although mitigation was not mentioned in the Procedures Manval,it will certainly be addressed in the birds and non-game mammal studies.In order to strengthen the interdisciplinary coordination concerning mitigation. the Principal Investigator for 9ird and non-game mammal studies has been added to the mitigation task force as described in the Big Game Procedures t1anua 1. General Comments on Wildlife Ecology Procedures Manuals Comment; There is acompe 11 ing need to integrate the wi 1dl He and the pl ant ecology studies so that the end results are meaningful and useful to the decisions which will be made.Each of these study elements should apply appropriate quantitative methodologies to evaluate animal habitats.The methodology used may depend on the characteristics of the species or group af species they are dealing with.Whatever method is adopted,it must be biologically justifiable and provide a relative estimate of the habitat va lue per area un-it for the study area. Response: The assessment of impacts will be based to a very large degree on project-related disturbance of wildlife habitat.Although the inter- relationships between the plant ecolDgy studies and the various wildlife studies were not emphasized in the Procedures Manuals,there has been, and will continue to be,a highly coordinated effort between Subtasl<s 7.11.and 7.12.' 13 .... ,~ - ..... .... - Subtask 7.12 Pl ant Eco 1og,Y: Comment 1: The s-eope of these studies needs to be expanded from the dam site al1 the way to salt water.The reason for this 15 that construction and operation of the dam will impact vegetation to that extent. Response: Under Phase I,the present intent is to extend 'certai"n of the plant ecology studies'downstream to Delta Islands.The degree and extent of impact downstream,especially.below Delta Islands,has not as yet been defined.The impact downstream will depend,to a considerable degree. on the facility design and hydrological information which is not currently available or not finalized.For this reason,it was initially decided that it would be best to wait until the extent of hydrologic impact is known below the Delta Islands"before.specific vegetation studies are perfonned for this region.If studies are warranted below Delta Islands,then they would be proposed for Phase II. COnvnent 2: There needs to be a high level of integration and coordination between the plant ecology,hydrology,and the wildlife impact assessment studies. This is because,a g,reat part of the wildlife impact mitigation will be based on vegetation. Response: \<Ie agree that a high level of'integration and coordination between the plant ecology.hydrology,and the wildlife impact assessment studies is needed.The need for this integration and coordination is stated in several places in the Plant Ecology Procedures Manual.There is a major section entitled "Input Required From Other Sources's in which subsections entitled "Hydrology".and I·Wi ldTife Infonnati on"are incl uded.The need for coordination among disciplines is also stated in several of the Wildlife Procedures Manuals and was discussed in detail under the response to the general comments under Subtask 7.ll"Wildlife Ecology.In surrr.tary, we believe that the need for coordination has been recognized from the outset.We feel that we,have fulfilled this need to date and plan to continue to do so throughout the study. Convnent 3: The deflnition of wetlands used for classifying habitats should be compatible with data already collected in the Susitna Basin by the cooperative study underway with DNR,AOF&G,and SCS.We recommend that the classification system developed by the U.S.Fish and Wi1dlife Service and described in "Classification of Wetlands and Deeo Water Service Habitats of the United States ll (FWS/OBS79/31)be considered as the wetland classification for these stUdies. 14 Response: The classification system developed by the USF&WS for wetlands and deepwater habitats will be used for the wetlands mapping effort:There has been some coordination with the SCS concerning wetlands and there are p):ns for additional coordination with AOF&G and ONR. Subtask 7.14 Access Road Analysis Conment 1: The ana1ysis of alternatives does not indicate whether stream crossings wi 11 be reviewed to determine extent of icing and adverse envi ronmenta 1 impact as a result of crossing these streams.Stream crossing and structures should be designed to avoid creating icing and erosion problems. Response: Stream crossings are an important part of the.access route envi.ronmental analysis and will definitely be considered in routing and later in impact and mitigation planning for the selected route.Included in impact assessment and mitigation planning.will be analysis of designs to avoid potential ice dam problems during break-up,and associated erosion problems_Consideration will also be given to minimizing erosion problems.Consideration will also be given to minimizing impacts associated with actual construction of bridge facilities and culverts. i.e.habitat disturbance and erosion potential. Comment 2: This analysis should include assessing the effects of an increase in fishing due to newly opened road access as part of its scope of work. Response: The analysis will include assessing the effects of an increase in fishing duoe to newly opened road access.The potential impacts on the fish community and habitat from a biological standpoint will be addressed under Subtask 7.10,Fish .Ecology Studies,and the recreational impacts or conditions·resulting from increased access to this area will be handled under Subtask 7.07,Land Use Analysis.In like manner,other environmental subtasks (e.g.vegetation.cultural resources.wildlife) will deal with increased access as it affectsthes~specific disciplines. Comment 3: There is an obvious linkage between access roads for this project and land use/fish and wildlife studies.Review of the manuals does not indicate that the approoriate process or mechanism is in place to see that th is occurs •. ...._~._~--~~~1~C\L-------- ..,., ""'" Response: Subtask 7.14 (Access Road Environmental Analysis)is essentially a coordinati on subtask for thi s sped fi c project component since it has obviously far-reaching impacts.The Procedures Manual states that the actual analysis is to be done by Principal Investigators within each environmental 5ubtask.A major coordination effort was felt to be necessary due to the interplay of roles between APA.Acres,R&M,TES, AOF&G -'n d the va ri ous envi ronmen ta 1 subcontractors.To th i s end I correspondence exchange and maps and information exchange has occurred since April,1980.In November,a meeting was held in Anchorage at which time representatives of APA,Acres,R&M,TES,ADF&G,and other envi r'onmenta 1 subcontractors di scussed vari ous a1temati ve routes. Info'nnation exchange continues on a dai.ly basis.and will continue through route selection and preparation of the FERC application. General Comments Corrment: It is the consensus of tte Steering Committee that each study task Procedures Manual should include two maps: 1.A map that delineates the boundaries of the specific study tasks described in the respective manual. 2.A second map delineating the overall study area,i.e.,from the mouth of the Susitna River to thE Denali Highway. Response: 1.Maps of specific study areas would ce~ainly be useful.In several subtasks,part of the work performed during the first year was a determination of the appropriate study area.Such maps are thus planned for the 1980 Annual Reports and will be incorporated into the respective Procedures Manuals with the next required amendment to each manua 1. 2.A composite map showing the relationship of specific.study areas wi 11 be presented in,our summary annual report. 16 i~i~'r'Ei1;).1:\t.j~i1 ~j j I "-'''::-:-':"''':;'~\I~~.._.;...._•._.•_..._:....~•v·....."~_..--...',-'...-..........:',. 1.POPULr..T lON A.~opulation levels 1.His"torical 2.Present 3.Proj ected 4.Component of Change (births,deaths, in-out migration) 8.Ethnicity,Culture,Religion C.Population Distribution (city,borough, state)by: 1:Age 2.Sex 3.Race 4.Occupation (general) 5.Education a.Retired,I'/age,salary b.Sector,activity c.Employment D.Population Density E.Family/Household Characteristics Extent 2.Marital Status 3.Migration patterns a.mob~lity/stability b.point of origin c.out/in migration 4.Length of Res i dence d.in house b.in com;nun ity c.in state 5.Place of work (com~uting distance) F.Attitudes Toward Change/Economic D~velopment G.Projecti ons Each of these categories and variables will be addressed to the extent that data and information allow and to the extent that they are releVant for the purposes of this analysis A.Historical lnfo (growth rate) B.Type 1.Single family 2•Mu It i .:.f am il y 3.Mobi1e home 4.Recreation Facilities 5.Transient Faciliti~s *Variables to be considered for above a.number of un its b.quality c.cost/prices d.vacancy rate - C.Vacancy Rate -0.Status 1.Renting 2.Buying J.Own 4.Other· E.land availability F.ZDning/Buil~ingRe9ulations (&patterns) .- .... G. H. Financial Climate (incentives/disincentives) Real Estate Activity 1.Sales 2.Construction 3.Plans .... A.Government Structure/Organization 1.Tal-ins 2.Cities 3.Borough s 8.Government Services 1. 2. J.;. 4. 6. 7. 8. 9. 10. lL 12: 13. 14. * Water Supply and Treatment Waste Water Treatment Sol i d ~,I as teO i spa sal Police Protection Legal System (courts,retention facilities) Fire Protection Health Care (including Social Services) Parks and Recreation Libraries Education (day care,vocational,others) Public Transportat{on Roads and Hi ghway Syste! Telephone Service/Communication Electric Power Service Variables to be considered for above a.Service area b•Usage fi_g u res c.Deployment patterns (distances/response times) d.Capacity figures e.Condition/quality f.Relevant standards g.Occurrence rates h.Plans for expansion i.Government expenditures C.Tax Base and Revenues 1.Taxes a.personal i.rates ii.base b.industry i .rates ii.base c.Sales i.rates ii.hase d.other I\'..,.. \-. 2.Other revenue sources Government debt (borrowing capacity) D.Projections A.General Description (Sis~ory and Area Trends) B.Total Work Force C.Employment l~u1tipl ier D.Output Multiplier E.Major Basic Industry Description l.Construction 2.I~i n in 9 3.Agriculture 4.Timber and related products 5~Manufacturing 6.Fishery 7.Oil and gas 8.Transportation ; .Ra il ii.Air iii.Motor transport iv.Harin~ 9.Public Utilities 10.Conrnuni.cations 11.Wholesale"trade 12.Retail trade 13.Finance,insurance,real estate 14.Services 15.Public Administration (Federal,State,Local) 16.Tourism lr Variables t,Q be co'nsid-ered for ab-ove c.history b.statistics (present sales,prod.,etc.) c.employment 1.1abor force 2.per cent Q f tot a1 \'/0 rk for ce 3.payroll 4.average wage rate d.resource base (land use) e.servi ce area f.us age fi gures g.capacity h.condition/quality i.product value j.~arketing patterns k.relative to state and U.S. 1.future outlook - !~ F.Conclusions G.Projections H~... A.Historica1 Labor Ch~nges B.[f'1ployment 1.Present Profile (efilplo)li7lent by st:'ctor) a.absolute b.percent age 2.t1ultipliers a.basic industry to b.export trade sector c.services 3.Length of work week 4.Seasona 1 i ty C.Occupational Staffing Patterns by 1.Sector/Industry 2.Ethnicity 3.Sex 4.Unemp 1o,;liIlent 5.Percentaae of work force 6.Wages (selected occupations) D.Working Conditions and Absenteeism E.Union Presence F.Unemployment for Area 1.Age 2.Sex 3.Race G.Income 1.Hi story 2.Per Capita Income a.General b.Sex c.Ethn i c ity 3.Source a.Wages/salaries b.Social Security 4.Subsistence income (moderate standard of living) 5.Consumer Price Index (CPI) H.Projections 1,1 •~, J ••I ,",,·r.....:...1':.,-USE: A.Hlstorical/General B.Land Tenure (ownership) C.Existing 1. 2. 3. 4. S. 6. 7. 8. o-'. 10. ll. 12. 13. 14 .. 15. 16. Forestry Aqriculture r1 in i ng Timber Native Lands Federa 1 State Parks Oil and Gas Unexploited Natural Industry/Coiilllerc;al Urban Rural Residential r1i1 i tary Transportation Resources .. ...' ,- - - D. E. *Variables to be considered for above a.acres b.value c.ownership d.management plans e.historical trends f.percent age of tot a 1 Population Density Land Use Plans and Control 1.Public 2.Private 3~Municipalities 4.Borough 5.Flood plains F.Projections .r...Utllizing Fish &Wildli;"e Resources 1.Sport Fi shery a.A11 speci es 2.Wildlife a.Caribou b.r~oose C.Black Bear d.Brown Bear e.Mountain Goats f.Sheep g.Wolverine i.Waterfowl,Birds j.Other Furbearers *Variables to be considered for ahove 1.Historical 2.Present a.area (acres and location) b.effort (visitor days/#of visitors)- c.Success (harvest) d.Resident (pt.of origin/r.of total) e.Non-Resident (92n.geo.pt.of origin/ %of total) f.Species (stats relative to State) g.Subsistence (personal consumption/ business) h.Trophy i."Management Plans ..i.Reoulations i1.Revenues (total/:-elative to state/flow of money) iii.Enforcement (ways/numbers/capacity) B.Not Related to Fish &Wildlife Reserves 1.Water Sports (canoe,kayak,rafting) a.Historical b.Area 1.effort 2.resident/non-resident pt.of or191n 2.Land Sports (hiking,picnicing,climbing) a.Historical b.Area 1.effort 2.resident/non-resident pt.of origin C.Other ,.-(~,..r.-)Vl;:.1._U.t:... D.?e1ated Business 1.Guides (#/S) 2.Air Taxi ODerators (#/S) 3.lodae Owne~s (#/S) 4.Land Owners (#) ..... - - E.Projections 23 JUN 1980 ~r.Eric P.Yould Executive Director Alaska Power Authority 333 West 4th Avenue.Suite 31 Anchorage.Alaska 99501 Dear Mr.Youldl This letter transmits to the Alaska Power Authority,(APA)comments of the U.S.Fish and Wildlife Service (FWS)relative to fish arid wIldlIfe aSPQcts of the Su.ltna Hydroelectric Feasibility Study_ Our comments are based on a reviev of the February 1980 Plan of Ztudy {rOS)developed by Acres American,Inc.,coordinatIon with Acres.other federal and state resource agencies 1nvolved in the Susitna project.and field reviey of habitats of t~e prqject area rotentially affected by a hydroelectric project. -Generally we believe that most of the environmental studies outlIned In the February 1980 POS are adequate to obtaIn data from whIch to a6sess the 1cpact8 of a hydroelectric project on the Susltna River to fish land wildlfe resources.However.the studies outlined in the P0S pro~lde a general overviev of goals and expected results.Thare is little reference to the specific methodologies of research desIgn, specific timings of etudy initiation.methods ot data analysls,and anticipated format of results.Consequently,we are unnble to fully evaluate study ?lane.Apparently.more ftpecific information i8 available in study-specific procedures manuals.Review of these manuals may clarify some of the concerns expressed herein.At thIs time.ve formally request a copy of the procedures manuals tor the fIsheries,wildlife ecology,and plant ecology studIes for our review. Eased on our revIew of the POS and discussions with Acres,we believe that the follOWing deficIencies of the envIronmental studies require attention.The schedule for l1ceruse application and submittal of an ExhibIt S to the Federal Energy Regulatory Comols6ion (FERC)does not Olilow sufficient time to include a rigorous evaluatIon of project impacts to fish and wildUf(!re'sources or p'rcparatlon of a plan to mitigate and conpensate impacts to those r~90urces_ Although "UdUle ecology studies are comprehensive 1n ,that they Include avifauna and big game,furbearer.and nongame mammal investI- gations,much less enphasiR 10 placed on obtaining data on nongame ~acima18 and avIfauna than selected game Bnd furbearer species.In ._---~»----------~------------------- addItion.no Mitl&8tIon plan,or s;tudy of these animals dO\mstrealll [rol11 the da~lsIt(~18 I!:ent Ioned In the rose DiscussIons with repre- ~cntatlveG of Terrcstrial F.nvirolIDcntul SpecIalIsts (TES)indicate th.!lt they int.cnd to develop r'lltIr,at!on plans for nongame wIldlIfe nude6tabiish study areas GO\.-nstream from.the damsltes.It 1s lr;:pcrative that WI?revIew these tasks for adequacy.The National Fnvlronncntal Polley Act (lIEPA),Pish tlnd lHldlife Coordination Act, and other ptldel1nes requIre that'InpactS to 811 fish and wildlIfe rC60urces he IdentIfied anti mitigated.Furthctlllore,we belIeve that the aSSCf;S!~('nt of project inpacts he h:t8crl on ,the overall value of habi tats to endemIc species Yll1ch Includes but is not solely depcndent on populatIon data. CO~nf'nt9 ane questIons specIfIc to tasks descrIbed in the February 19130 POS follow: Subtask 2.10 -Access Roods .... D Please provIde us a map of the Alternative access routes 8S s-oon as avallable nnd !ndicRtc If the selected route'(s)wIll be temporary or pen::anent • f.ubtask 2.16 Hydrographic Surveys o ~~y are rIver profiles limited to Talkeetna and above?In order to cfltab Ush hackr,round datA to mC8sure potentIal change in the river co'nfiguration and habitAts dovnstrearn frOQ Talkeetna, should prcfiles also'be taken In t:.hIs area In conjunctIon vlth data ~o he collected under Subtask ).10? Subtasks 6.09 and '6.10 -Establish Design Critcria for the Watsna and Devil Canyon Development •Are designs of potential mitigation 6tructures included here? Subtask 6.14 -Spillway Design CriterIa •Do these criteria include continrency nea8urcs to 8voId water QualIty problems such A8 nltror,en supersaturatIon? ....Task 7 -I:nvironmental Studies •Because the FilS Is Invol vcd In a nunber of permit tinr.and review functions relatIve to the SURItna HydroelectrIc project o we lmuld appreciate being I~ept Infonlled of project progrcss. nlUS,"-Ie ,Ire rcquestinf;cories of reports prepared for envlron- Qcntal discIplines (hydrology,fIsheries,wildlIfe ccolo~y, plant ccology.hahitat AnalysIo)as they ar~revieued by APA. SUbtS6k 7.2 -Honl[orJng of Field ActIvItIes for Environmental AcccptabIl1ty • •~everal study activitIes will potentlRlly i~pact mIgratory bIrds Inclu~in~\lAterfowl anli raptors.He sugr.est that the Acres or ArA fIeld representatIve contact the FWS to be certaIn that he Is a~are of data on bald cagle nestIng locatIons, trumpeter 6\1an nesting habItats.and other pertInent data. Also.we \"ould like to be provIded the opportunIty to periodi- cally monItor activIties that ~y dIsturb raptors and other migratory bIrds.Therefore.ve request a schedule of the tIrnt.ng and duratIon of study events that Include actIvIties that potentIally disturb waterfowl and raptors.We are partIcularly concerned with survey and aerIal photography activIties requIrIng helicopter support. SuhtasK 7.09 -Sugltns TransmIssion LIne Assessment •Remote lakes In the Matanuska-Susitna Valley are utilized by trumpeter swans for nesting and rearIng cygnets durIng aummer f . and fall.Recent data indieata·that continued developDent·.nd dIsturbance on llIkesUsed for nesting is cauaing birda to abandon cer~aln areas.The selectIon of •transmIssion corridor should be accomplished cognizant of the habItat requIrements and movement patterns of mIgratory birds. Subtask 7.10 -Fish Ecology Studies •~~jor comments concernIng fIshery invegtlgatlons vere pr~vlded to APA In previous ~orre8pondence.From the information pro- vIded In the February 1980 POS,yc are uncertain of ~he precise timIng of initiation of study tasks..'e vould appreciate . receipt of the present schedule of fishery related studies at your convenience. Subtask 7.11 -Wildlife·Ecology Studies • • • Data collected for habitat analysis should be done in a manner to accommodate all terrestrIal wIldlife.This wIll permit an evaluatIon of the effects of habItat alteration on wildlife In terms of hebitat unit values. Any mItigatIon plan developed mu8t be developed in cooperation vith resource agencies as defIned In the Fish and ~11dlife CoordInation Act.Also,the r.litigation plan should be incor- porated into the ExhIbit S of the fERC license application. necause many of the field studies have been inItiated or ·sre scheduled to cOmr:\ence soon,it is imperotlve that "n Intense survey of the project nrea be conducted for peregrIne falcons prior to the InItIatIon of potentIally dI8tu~bing activities. Subtask 7.12 -Plant Ecology Studies .... - - • • • • Un~er.the FERC process.sufficient datil must be obtainod-to develop a biologicel assessment of ~ndangered species relative to the potential impacts of project activIties.Based on the biolor,lcaJ assessnent.the FERC Il\ay be required to consult "Ith the ~~5 concerning endangered species under Section 7 of the Endnn~('rcd Species Act.The consultation process will be grclltly ('xpedlted if·suff icient data hilV6 been gathered and evaluated In the initial study phase. The outlInes for avifauna and nongame rnaf'!lll'.al studies are quite general and it is difficult to deternine what will be accom- plIshed.The objectives snd goals need to be presented In more detail. P~cent surveys of the 5ueitna RIver and tributaries located more bald eagle nests along the Plain river below tho damslte ~han previously expected.Consequently,the impact of altered flow on eagles aeeda to be assessed. An l~portant objective of the plant ecology studies is ~o measure potential habitat change over time.Habitats In the area of project influence should he ~pped at 1:63,360.This 9cale should be expanded to 1:25.000 in riparian habitats downstream from the dsmslte(a)that will potentially be altered by the project. Vegetation cover maps and habitat requirement charac-teristlcs of wildlife should be compared to determine the quantity and quality of habitat lost for wildlife groups and to predict impacts on species of wildlife.This implies that wUdllfe and vegetation studies be conducted in a complementary manner and that the purpose of plant ecology studies be kept in full view. Cover type maps are of lIttle use for predictLnr.Impacts If the habitat requIrements of ~Ildlif~speci~s are not known. Subtask 8.04 -Tower.Hardware,and Conductor Studie6 •Studies should include desIgn of a transoi891on lIne to avoid oiectrocution of l"8ptors aod collision3 ~"Ith I'\lcrlltory birds. Subtask 9.02 -Prepare PrelJminary C05t EstimAte •Cost estlmates should include the costs of added features to ~it.il'.ate impacts to fIsh and wildlife re!'JourCCB. As you are avare.the f"olS Is required by federal lavBancl ;'lollclc;s to ensure that de.cislonmakers Arc provIded Infbrnatlon ""hereby vildlife values can be fully considered And veiKhcd equally vith other features 10 the plannIng of uater resource development pro- jects.Ah a result of these responsibllities.we have an o~llgatlon for Insuring that an adequate Exhlbit S is prepared.F~hiblt S is paranaunt to the designIng of an envIronmentally sound project slnce Its purpose is:(1)to identify and evaluate the effect of alter- natIve project proposals;and (2)to describe measures necessary to cOllserve and enhance fIsh and wlldlIfe resources.ExhibIt S,there- fore.should contaIn a mItIgation plan and functIonal desIgn dr8~Ings or other project features as ~y be determIned necessary for the protection,conservation,Improvement,and mitigatIon of losses to fIsh and wIldlife resources. Ue can see no advantage 10 presenting an applicatIon to FERC.which 101'111 be reviewed by ~~S.that does not ~ontain an adequate assess- m~ot of projecttmpacts to fish and wIldlife resources and practlc~l QItigatlon plan.SubmIssion of aD P.xhiblt S under a compressed tIme fra~e can only hInder the desIgning of an envIronmentally Bound project.TIle FWS recommends that the lIcense application be delayed untIl suffIcient hiologIcal data are available. Thank you for the opportunity to co~ment on th!R project. Sincerely. . 1 Signed byOrlgtn~Schretner I<.e\th n. A~ea DLrec-tor cc:AOES.WAES ELM.ADF&C,NNFS.Anchorage n'S/OEC.FERC.'Haahington D.C. AlASKA PCMER AUl1IORI1Y September 12.1980 :~r.Kef th Scrlrei ner Area Director Fish &~ildlife Service Department of the Interior 1011 East Tudor Road f\nchorage,1\1 aska 99503 Dear Mr.Schreiner: This is a response to your letter dated June 23.1980 transmitting comr.;ents relative to fish and wildlife aspects of the Susitna Hydroelectric Project feasibility Study.We would have wished that you had been able to ~rovide your written comments sooner in as much as our Plan of Study (peS) was published and distributed in February.It was difficult to alter our first field season program with your comments arriving as they did in late ,June.Despite the lack of timeliness,we definitely appreciate your comments and have given them careful consideration.t1y responses are keyed to the page numbers and paragraphs of your letter.a copy of which has been attached for easy reference. Page I,Paragraph 2 The studj'-specific procedure manuals for the majority of the environmental 5ubtasks have been completed and were submitted to the Susitna Steering Con~ittee during the week of September 1.1930.A complete set has been designated for Hr.Don McKay.F&WS. f~ge 1,Paragraph 3 ~e view our P~S as a two-phased effort with impact analysis and mitigation planning (as well as data collection)extending beyond the date of license application.In the Plan of Study (POS)and Procedures Manuals.pre-license application and post-license application studies are referred to as Phase I and Phase II.respectively.The anticipated post-license appli~ationstudies are summarized in Section A-6 of the February 1980 Plan of Study and were described in even greater detail in the Technical Appendix of the September 1979 pas;these plans will be refined on the basis of Phase I findings. Page 1.last Paragraph.continuing onto Page 2.Paragraph 1 The nongame studies cannot be rigidly compared to game and furbearer studies.Differences in study effort,as reflected in budget allotments. f-result from a variety of reasons.including equipment and logistic expenses. ~r.Keith Schreiner September 12.1980 • Page Two AlASKA POWER AlTIHORlTY • differences in home range and habitat use.recreation and economic importance, and life span.The nongame studies will allow a thorough evaluation of impact and.if necessary,sufficient data to develop a mitigation plan. At the present time.,limited furbearer surveys are planned downstream of the Devil Canyon dam site as far as Delta Islands.Some avian studies will be conducted downstream as far as Gold Creek.No avian studies are planned for the area south of Gold Creek other than an aerial survey for raptor nests,which will be conducted in 1931 if deemed necessary (as discussed in the response to the comment of Page 4.Paragraph 3).The approach of Phase I studies is to concentrate in areas where impact \.,111 definitely occur,such as the impoundmentlones.Since the extent of impact on downstream habitats, particularly those south of Talkeetna.cannot be predicted untfl further progress 1s made ,on the hydrology and engineedng design studies,only limited effort was appropriated for this aspect of the project.If the results of the Phase I hydrology and englneerin~work indicate that major changes will occur downstream,the Phase II ecology studies will be designed to evaluate in more detail the downstream habitats. page 2,Subtask 2.10 -Access Roads As soon as available we will provide a map of the alternative access routes. The question of whether the selected route{s)\.,i11 be temporary or permanent is part of our ongoing studies which will require input from various dis- ciplines and government agencies including F&WS.F&WS advice will be sought in this regard during the impact/mitigation phase of our studies. Page 2,Subtask.2.16 -Hydrographic Survexs As discussed and agreed to in the Susitna workshop of July 17-18,1980,the question regarding the necessity or feasibility of establishing detailed river profiles downstream of Talkeetna would be postponed until the spring of 19B1.Following the acquisition of 1980/81 winter fisheries data and a reconnaissance assessment of the Susitna hydraulic characteristics,a decision on the development of river profiles downstream of Talkeetna will be made. Page 2.Subtask 6.09 and 6.10-Design Criteria for Watana and Devtl Canyon Development . These subtasks wf11 include the establfshment of design criteria for mitigation structures as required. fage 2,Subtask 6.14 -Spillway Design Criteria These criteria will include contingency measures to avoid or alleviate water quality problems such as nitrogen supersaturation. !1r.Kei tit SchrUl ~er September 12.19dO rage Three ~a~e 2.Iask-l-=_Environmental Studies It is our intention to keep F&WS and other appropriate government agencies informed of our progress and will forward copies of environmental reports to you in a timely fashion. Page 3,Subtask.7.2 -f~onitorfng of Field Activities for Environmental ___________Ac~eptabil ity _ As part of our program to acquire existing information,F&WS will be contacte< regarding data on bald eagle nesting locations,trumpeter swan nesting habita1 and other pertinent data.Nest locations ~iscovered are now on file at Watanr. Base Camp and helicQl1ter pflotsare kept informed of areas to avoid.Oetailec records are being maintained of activities requiring helicopter support. Thes e records can be acqui red by contact i ng Mr.Ji m Gill.Ac res AIDeri can Incorporated,Anchorage. A listing and general schedule of study events that may disturb waterfowl and raptors can be supplied;however.a detailed meaningful schedule would be difficult to develop since location-specific scheduling is done on a day-to-d~basis as study needs dictate.If F&WS desire an activity listing, please advise.Upon request,we could then provide F&WS (with short notice) the actual timing of sped fie events. Page 3,Subtask 7.09 -Susitna Transmission line Assessment Available biological data,such as F&WS data on breeding areas for trumpeter swans.will be used in the envi ronmenta 1 assessment to be performed for the transmission corridor. Page 3,Subtask 7.10 -Fish Ecology Studies As F&WS are aware,the fisheries field studies are to be conducted by ADF&G. As soon as AOF&G acquire the staff to conduct these studies a detailed schedule and procedures manual will be prepared.Upon receipt,we will forward this information to F&WS.A general schedule for impact assessment and mitigation planning is included in the TES procedures manual. Page 3,Subtask 7.11 -Wildlife Ecology Studies We sha re the F&WSconcern for app 11 cab i 11 ty 0 f hab ita t ana 1ys is to all terrestrial wfldlffe.As described in the various Procedures Manuals. habitat data specific to each wildlife group are being collected in the various subtask disciplines,and in tt'ie plant ecology subtask.In a manner that will be appltcableto all groups of wildlife. Cooperation with resource agencies in the mitigation planning,process is proposed in the Procedures Manual for Big Game Impact Assessment and Mitigation Planning.The extent to which the mitigation plan will need to be further developed during Phase II is also discussed in this Procedure Manual. Iii".I ...t;t L..II ...;\",.IH .............., September 12.19dO Page Four An aerial survey was conducted for peregrine falcons in early July 1980.and none were found.Other study team members have been advised to report any incidental observations to the TES Field Representative.If any peregrines are seen in the course of the study.team members will insure that all potentially disturbing activities are scheduled to avoid areas known to be used by the peregrines.We are confident that our endangered species program will provide adequate data and analysis thereof for review of the Susitna Project by both F&WS and FERC. The Procedures t~anua 1 for Bi rds and Non-game r'~ammal s provides many additional details concerning the study effort. The aerial survey for raptors.conducted in the impoundment zone during 1930.will be evaluated and if deemed necessary altered or expanded to cover the downstream area.Serious consideration will be given to extending the 1981 aerial raptor survey to Talkeetna.A more intensive analysis will probably not be conducted until sufficient hydrology and engineering work has been perfonned to determine \'/hether the expenditure of additional funds is warranted. £!..~Subtask 7.12 -Pl ant Ecology Studi es The plant ecology mapping efforts are in exact agreement with those recommended by Ff"WS.These mapping scales were identified in the February 1980 Plan of Study.having been determined on the basis of a coordination meeting held in October 1979 at which F&WS was representated. One of the major purposes of the plant ecology studies is to allow a compre- hensive evaluation of habitat alteration that may result from the Susftna Project.Habitat data are being collected 1n conjunction with cover type mapping that 1s being performed in Phase I;plant succession studies are being conducted in Phase I;and an in-depth moose habitat study is planned for Phase II.In addition,ADF&G is collecting habitat data throughout the study. Page 4.Subtask 8.04 -Tower.Hardware)and Conductor Studies The transmission design team will review literature on design consideration to avoid raptor electrocution and incorporate this.as required.into the design criteria.If the transmission corridor routing analysis to be per- formed under Subtask 7.09 indicates a potential collision problem at any specific location.special mitigation efforts will be incorporated. Page 4,Subtask 9.02 -Prepare Preliminary Cost Estimate Cost estimates for mitigation efforts will be prepared on a preliminary basis during Phase I.Cost estimates will be refined during Phase II. Page Five Pa5L~_~--=-_E_~1 i b i_!:.-~ As outlined in our pas it is our objective to submit the FERC an adequate license application by June 1932.Our application will contain an assessment of impacts to fish and wildlife resources and practical mitigation measures. It is realized that Phase II studies will be required to confirm some aspects .....of our assessment and to finalize mitigation plans.If for unforeseen reasons it is detennined in 1982 that an adequate application callnot be prepared on schedule,we will reassess our position.Once again your timeliness in the future would be very much appreciated. Sincerely, trlC p.Yould Executive Director Attachment: letter from 'Keith Schreiner dated June 23.1980 cc:Tom Trent.AOF~G Brad Smith,NMFS Curt t'1cVee.BLN Dean Shumway.FERC APPENDIX EllC CORRESPONDENCE RELATING TO DATA COLLECTION AND PROJECT ASSESSMENT .... APPENDIX 11.C DATA COLLECTION AND PROJECT ASSESSMENT \ All big game and fisheries basel ine data were collected by the Alaska Department of Fish and Game (ADF&G)under a Reimburseable Services Agreement with the Alaska Power Authority.ADF&G had a major influence on the direction, scope,and schedule for these studies.Annual reports for all the environ- mental subtasks were distributed in April-Mqy 1981. This appendix contains correspondence concerning transmittal of documents to resource agencies and their response to_these documents.Subjects include review of access road reports,transmission line siting reports,annual 10 .0. environmental reports,and the Susitna Hydroelectric Project Mid-Study Report. Correspondence is presented primarily in chronological order.However,in some cases,a response to a letter directly 'follows the letter to facilitate an understanding of the flow of communication.This results in an interrpution in the chronological sequence • :~" FIL~~ \ i ;! ::E'm , z -' 0 a;-iE < i=a ...E iII:.:en0~6 :;1<'. :.Dew :, ----: MRV i ~f e :JPS .J •~------i.-•,.,I~.~i ~:r~J:/1 -~\t~ f--~rl~ .--t T!,.I .--,.I I f .:-I=JI• t ---i I.\-1I, ():.L _I ..-1 i i 1)'-7/Wlf''j10--0.-.. _•• S£P 27151,9 W$A P'~~iuJHC~lt RECEIVEO·OCT I 0 i~79 RECE1~eb UNITED STATES DEPARTMENT OF THE INTERIOR F~SH A='lD WILDLIfE SERVICE 1Qh (~,"ltX)""I.() A~CHORAQE.ALA!KA~9S03 .t907J 2763iOO De..sr Mr..Yould: ~..r.B~ic:1'..tould E~~cutiv~Director Ala~k4 P~r AuthQT.ity 333 WCJ;I;.4tb hv;;:1l\lt:y S'.li.te 31 J'.ncJ~orase.A1ask~99501 . Ye vereinf.o~d ~y YQn~l~tte~OT Aup.u~t 23.1979 y tb~t th~Ala8~ Po~~~th9.1ty(AP"')is pre]1at'i~an'application for licen.ge to ~ Fed~ra1 Energy Regulatury ~-m~~=iaD (PERC)for ~he prcpQ$cd Rydro electric l'over Development VJ.tbin the Upper Su."i.tTJ~lU.ver 3.2.;;iQ., A1asKa.the purpcse o£th1~1ett!:!ru tu point out fede~al fi:;b or. ~ildlife r~PQn~lbiliti~and to in@Jr~adsquate eonside.ration of l !:sb and V1.idli.fe rer.out'~~101:3 p~~ventiOn7 J2ti ti.1i:tiOl1 ~C:0iJPcntu;- tion~and enll.QDce~tit drtoughout tbe pla.tla1.J.ng a:D:1 ded.ifi.On-roaUng pro~e*s a~Hoc:i~tcd ~th th~8u6itT~r-roj~et•. "lb~pt'(l-applieation plBnn1~period asB,,~!at~.i w1th t;he propo$ed Su:tit:~B)'d!."'Q~lectric Paver DiL~lcp'!JIC.nt is;veo-er.it'tl;!,;al.Qon~i~e'I"~ the magn1tud~\af tbe project,limited e~~tirl8 data Eor £Leh ~n~ -wildlife re20~C~~.,3~d ~unt o£e£;ort requi~ed io~the tiling D IJ vGlt"c(lnc~ivi?d applicstion for !i~enae ~L'1 FERC.1ll'··adtlitioD, c~prebc~givc Q~,ly pl~nni,,~1$T~qQi$itg to th~d»*1r."i~!Qr 3n'· C:D\"i~onmc:nt;s11y AQund PTojll,1Qt ;;udQPti~Dl ~c of the pl;,sn~il1g ped .th~rsby edD~zing the potential for d~la1 in the processin~of n~o~~~~9 pn~t and lic~n8~~pplio~tiQn~~nd CQ~11inr.with v~TiQ euvi rOlim=!n tal r:::v i~v t"t:qu i Tt:l!:Cn til.. It"REPt.V iUFfli roo . Peaer~asenc!u~ift701~~d in th.an~ly.!d aud/a~~pp=oval df a n~~-!eder~l water-~Qlated proj=ct bave m&uy ~~~poo~ib~l~t1eg un~er various ?t~ecut1vG Orders (BO).IB6~and polt~1ea 'to pr.cvent iI.Tld Dit{gate-impftt;ts·to f;t8n~:ild vildltfe rr.~O\lr~~9~;)$well ~~~o l;lTlhQm:a tohosc=t'C9Q\lrel.la..T.o idQn~ifl'and intl1:~c rec:cgnitio'D Qf d1.reet.1vee of u!Do$t importanc:e and r~le\la~ce tl)tile prote~ttoa of f1shand\rild.l:i.fe r'280UrCes,\0'\\'l1stthEt f{lll(1V1~6nd includ~& br1sf SUJlU!.\B.I)"of !!lI?SBUreS required: (1).'!be i'lSb .aud Wfldl1fe Coord1Dat1on Aet~draft uc.1forra Proc~dur~s for ~pliance,May 18~1979.8t~ndard1r.~8 pl:oc:edureJi :Snd·idt.tera;~ne)·relat1¢nsbi.pl!l101.n~u:et "that \dldl:!fe C'QnS4iorv.:ltfQn is f.,lly .,.on8iQr.rn~ilnd wt'l!ienQ4 equally vl.thotbe-r prcJ.:c::t f~ature-s·in a~cnc,.dec1sion~. !lAking ))I'OCE<BSe.S by inte:.rat-:!nfo ~l,r.h c,c::1't1s1d$t";)tions 1:n;0' PTQj~ct plan~ing,~atiQnal EQvirv~ntal Policy Act (NEPA) complianca procedures,fin&Dcial and e~onom1c4n81yseBt author!zet10Q do~u~ut$.aua proJect ~plece~~tlon." (~)The Cot1 noi.l Qll ~nviT'QTJT.lQnti11 Qnalit.,.'li (CE.'})Kc!u·10ltion, ,(orIaj:.l~llt1GS the rroc~'Jral pI'(".vie.ione -of th~l~.gtional ~rQns;'l~nti31 p"J i.;:y At,t (40 CP"P."Parts;1500-150B,.July 30,1919)~p~clfie~p:uvi~lQ~re~uir~g ~be ~tesrat1on of the·lrePA prQce.ss into Mrl:r pl.;1t111i·"QE~tnc in~f;g~i1tin'Q of HErA requirements with.otber emriTof'G:!Klnt.al rGvi~«Ad consultation requir~ment~.auG th=U$C of the ~~opi~ pr9t;c.$$. (3)SeclJ.o..o 404 r.)!the Cle:S!\Water'Act of 1977 and re9ult1~ final rule.s fOT i~l~~~tiQn of the ~egul~~ar)·p~~t prcgr;za of "the Carp~of Engiu~r~(33 CFR..P~rt.a 320-329 .. July 19.i.~17)reqU3.1:e!s that a Department of tilt'Army permit (8)be t)'l't.ained fOT ecTt.."in ..truct12:cw;or 'WOx:k.in or .ff~~tinx w~tcrs of the United StaLeb.!be 4ppl~cat1on(8) fOT $Iuch·.i1 pertait.(s;)will be ~bJeet to review by wildlife :lgem:ic$.. (4)Exe~Ut1ve O~de:r 11990 (~tland~)"''";l~i.;:wcd "in order to avoid to the eT-tant po::;sible th~loug-'Lli::l::'m a~d a-bort-terl:lt t!\hrr.:r,;a:bpacu iU&«)C1ated vith the d6gt~..Jction OT.'modi- .f~~tian uf weti~de a~d to avoid direct OT i~d~rc~t Bupport of ncv con~tru~tion in vetl~nds ~tlerever thet~is o!lI pJ:':a~ti~"1ble i!ltcr.o:~t~"e.'lll acd £~(:ut1ve Order 119tlS (:Flo~pla1:U)\/litS ~asuH fito ~vQid 't11 t.he r-x~e.:nt.pa~,.!ble the lo~-te.rm ~nd ~nort-term adyer~e ~paets associated vit.h tnB QCC:llpanc:t and mod1f.1cat~on of floodplitins <:Incl 'to avoid direct ~nd indirect ~uvport of floodplain de~~lop­ ~$~t vner~~cr thete i~a'practicable slt~rn~tivG."All ..f~;e;r.ai agenc.Ies are :r:~6ponsiblEt tQ i,:,o1<!Ply vit.h thes;e m':J in the plafJU..lng and ,decie.ion"Mkiug PTl')C~~9 (5)S~~tiDn 1{c)of the £~d~~gered Sp~c1~~Act,87 ~t"t.834~ 4$~ended7 ro::quift=e FEllC to ask tb*S*cret>1ry ~f the: loterior.acting thT~Ugh the:U..S.Fish ~~d Wildlife S~rv1c~, Vhether ~y lie ted or propose.d endanp'~r~4 Qr thrc~tcncd s;pe=d.es ~.).bi:present in th~nre.,of the SU5i.tuS.liydro- ele.ctri~P~r Projc:c~.It the f18h ~nd ~~ldlifo ~~TVicc O1QVi8eM t.h.,t.!mel!species GaY btt PLCF~llt i:1 1:.h~a~e::i of the project,F~C 16 r~qui~ed by S~~~iDll 7(c)to cood~ct a B101ogic~1 Ass~~~~~t ~o ide~t1fy 8QY listed or r-ropos~ enden~eL~d or thrc~~cncd Hp~c~eg which ar~liK~ly to b~ a.ffec:t~.ij by the:Cf)'ql;tnlc.t.ion p~oject.Ti1'it .aS8e.aFll'r€<Dt.-:~ to ~e cOl:lplc.ted \.Iit·hle leo uays,unlCJas a ti:me c.xt.cn:siOd if'T.:Utuall)·ar;rei:d upon. Hr.Eric:;p.Yould """ ,- .- No cm::It~act for pbY8ic~1 cont;l.ru~t1ou'bay bt"entered j.nLo 8nd TU1 ph'y:;ic:~l cOIl:ltructiQn J:IO£""j bcgiI1 untll the ili"lngic.:11' Aases8m~nt i~~ompl~t~d.In thQ ~vr.nt the coucl~1ons ch~aw from the !.iolo;lca1 Aase.s~~nt.i:Te tbal:11S'teo-J endanaer~d oC tlH~~ateQed spc:;tdl:!J;a~~llk~l)'to b~afft.\ctcd ~y th~cu~ettuct1on projeC~t lERe 1s required by Secti~ 7{a)to'1nit~~~e ~he cU~8ultat1on prncC~n. (n)ft~te~Re9~UrCaB r~uncilt r~10e~plea ~nd S~~ndard~tor r1~nnin~Wat~r'and Ue1atedLandR~~o~r=e~(18 CFH~Part 704~April l?1978)were established fa~pl~~the U9~ of the ~~ter and r~lat~d l~nd te$o~rcea of the United St.:1tI:S to ach:1ev~(lbjat:tivc.",det:ertrl.Ded coopi;r;i:t iv ely t t.n1'ougb tho€!coordiTti1\:l!d I'SctiOilli of the 'Yed~r01~y St;1tct-and locsl gover~~nt=t p~lvate ~Aterpri~~~d Drg~zat1oDa~ and indtvi4ua~&~Th~Bc priac1pJc~in~lude prov!din~th~ basi~fQr pl~~i~S of federal ~nd fcder~~i1 a=~L6ted-vater ~d 140d r~eOllTC@'(o :prosr;;m~and pro.leets an(J fedar.ozl. licsnsing ~9tiviti~as listed in the Stand~rds. I~~our understsndina ~b~t yuu~a&~nCY has contT~ctad with three i~dep~ndent con9ult~nt fi~fur ~A~h to d9V31op 3 ca.cprehe~lv~ plan of stud7 (POS)~u·lQclud~biological ~t»dic~~s~oc1ated ~1th tbc S1)~itl1a project.and that frr.a t'he three 1o.depe.nden:t post,s and the ex18t!~g CO"t"P8 of ~TJgineet'~1 Plall of $tudy y QU u1t:i.tao1J.'t~c.ompre- lzems1vI1LPOS will bs d~i"iv~d.The 12ctiocs necesssT:Y t"c'7iapl)'with th~aQQv~d liyted laws,policies.and F~t~dcmons~~ate the necessity for clo~~con~ultatlon vith fed~T~l ~d st~te w1idl1£e a&~ncie~ tllJ:'cmgnout ProJe.ct plaDI.!;in~and 'Unpl('''J..t:nL~l!uu. It.is;!:DpeJ:at.:be that coord 1~~t~d pla:anlng be in!t1.ate-aj nev .'"1 tf1 ;::11 apprupr!ate parties.«no that s'lcb plA~i~~1Dclud~th~convening of Seo?1ns msetin1.~to incLude purt1c~pation by $t~te ~nd T.ed~r~l wildlifl;;!~encit::l.'.l11e purpose of thQ l.9':;::0Fina r2:t!tl11g8 ahould includ4l~°(1f;,;,clqpinS .a C:t"::lpr~ben.81\T8 POS which i:u;ut"e~full wildl:!fe ~gcncy'part1e1pation·th~oQ&bout~ach ph~ee of th~pl~nnina and rcv~ev prQceaaes;de-t~~ining whu t aco~the i~~9Lal ~~d ~t~te \rildU,fe ~geDe1.e9 or the ;zppliC::!int~,,111 uDdertak~iin(J o''''cr.;:cc t.b~ required studicG ~nd iuveat1gs~ions;iC~ltins ~~~u~te ~dd timely funding of tnoge ?~rfOr=1D~th~$t~dic~;and ~~t~bl1ab1ng Botu81Jy ~C~Qptable targ~t dates for t~e initiatlon and co~l~ti~n nr ~~udie~. The 8dhcrcnce to th-=$~$uuestiona -:,I,ll ip!--ute that ade,~uat9 infor- ..~t~cn·1~~o!1~cted to~n~ble the deter~nat1on of paojr.ct i~actu ~':2d develop Q&~tu,li'"ns to pr~ven~t m.it:1~at$~~nd i::cm:pcn50o:i t~J!Clr f1.sh iUld 'WildlifQ ]o;;;;e..'1 .. H~.Eric P.Yould Y~lonle.f:;rrv;lrd to VQ4ltin.~cloeElly >Ii to YOJJt'af,,~nc.y and otb~r8tnvQlv~in ~his ~tu~y,~nd trust to~t this letter Vill serve ~~~tice u£the D~ce$$lty ~or ~~r11 i~~olv~~nt or ~Ud con~~l.t~ttonWLL~wl1dl1!e as~~c1es.. cc:AO!S,WAlS i'F-Rc.,~<l<;b'1nK'ton cS,'i-l&binHt-oD· OBC.WA21~3t.otJ Ct.AbP&G.AnchoIosge N'i:lF~t BL!i.ADNIt,A1)c:horese AVEC,EPA.SCS,USGS,Anells)T~RI; I""" I Mr •Gary Hiclanan Area Oi rector United States Department of the ~Interior .. Fish and Wildlife Service 1011 E.Tudor Road Anchorage,AK 99503 Dear Mr.Hi ckman :Susi-tna·Hydr.oelectric Project - Thank you for your 1 ~tter datedSeptenber 24 concerning federal fish and ....wildlife responsibilities for FERC licensing of the Susitna Project.We whol eheartedly concur that all activities related to 1 icensing of the project require careful planning and coordination with all local,state and federal agencies involved.We also agree that the environmental base- line studies,and the ensuing assessments and development of appropriate investigation,compensation and enhancement measures are of particular concern.We fu 11 y intend to address these matters in as comprehens i ve and thorough a manner as possible either through the Corps of Engineers or our consultants,Acres American Inc.Selection of the Corps or Acres is anticipated in November. Some preliminary scoping meetings have already been initiated on our behalf .by Acres American Inc and Terrestrial Environmental Specialists Inc with the Alaska Departments of Fish and Game and Natural Resources,the U.S.Fish and Wildlife Service and National Marine Fisheries Service.We have also been in touch with Ron Corso of the FERC to solicit his views on the approach we should take in obtaining the necessary .1 icenses for ..the project.It is our understanding that a key factor in the 1 icense application will be a valid demonstration to theFERC that all involved agencies have been consul ted and that pl ansforcompl iance with the appropriate regulations have been agreed.We have every intention of meeting this requiranent to the compl ete satisfaction of FERC.Referring to the list of "regulations in your letter we have been advised by Mr.Corso as follows: .... (1)Fish and Wildlife Coordination Act:FERCls own regulations will govern for federal licensing of the Susitna Project. (2)CEQ Regulations:FERCls own regulations will govern for federal licensing.... (3)Section 404 of the Clean Water Act:compliance is necessary. (4)Executive Order 11990 (Wetlands),and Executive Ord~r1l988 (Floodplains):FERCls ownregul ations arei:!xpected to govern in the case of Susitna . (5)EndangeredSpeci es Act:compl iance i snecessary ~ - 2 (~)Water Resources ~ouncil,Principles and Standards:these only apply for federal projects ,and would not apply if the state sel ects a private consultant to undertake the Susitna Feasibil ity Study,. You should also be aware that weare planning to directly involve the ADF&G,ADNR~and possibly other state and federal agencies in appropriate areas of study.We will gladly keep you informed of progress in all aspects of the study which are subject to your jurisdic~ion and look for- ward to a close and mutually productive relationship~ Sincerely yours, Eric P.Yould Executive Director -DIVIS/ON OF RESEARCH &DEVELfRfEN! 6 tS81 JAr.t HUlIIDIfD.'DrclJl. 323 E.4TH A VENUE ANCHORAGE.ALASKA 9950' 279-5517 March 26,1981 ..~~.2 2?1981 Jt.J,.}S.A PO\"I;a AUTHORlT Dear Hr.You~d: ~1lOWI!lI AU'IMORI1Y ~SUSITNA ---;"""';--4 Eric tould FILE ~J.f Executive D1rector.~Alaska Power Authority 'iEQUENCE NO.333 llest 4th.Suite 31FI{',7 t k Anchoraie.A1C 99501 'I~:t !~;.....j;;z_~~.~VS The purpose of this letter i8 to transmit to you the findings and ~recommendations of the Susitna Hydro Steering Committee in response to -._t J_D.G_--:l"-"--4.APA's request for input and recommendations on the selection of an lBJB access toad to the Susitna Hydro Dam sites.On March 6,1981,Alaska JKL Power Authority staff,contractors and subcontractors prOVided several -lRRH agency representatives with a briefing and a request for comments in-c=!~PB order to make a determination for surface access to the dam sites.Itr-:-lC;RI was requested that our comments be provided to APA by March 23,1981.t=---:H&N As a result of com~nts and concerns expressed by agency representatives AAA at the March 6 meetins,I agreed to convene the Susitna Hydro Steering r-+-+---~__~Co~mittee in order to identify and coordinate the concerns of those I APA agency representatives regarding access to the Susitna Hydro sites • .~wee The Susitna Hydro Steering Comv~ttee met on Friday,March 20,1981 •. TES We spent the afternoon discussing various issues and concerns surrounding ~&M access to the dam sites with the subcontractors to Acres American.As ~DF&G a result of these discussions and review of the pertinent documents, .~..-au;:F;--fi.;;(·report studies,etc.,the Susitna Hydro S.teering Committee makes the f ..ax.following comments and recommendations: .k- 1.The Steering Committee representatives recommend coordination betyeen the decision about access road routes and transmission line routes.Until this issue was raised by a Steering Committee member at the March 20 meeting there had been little discussion. The documents revieyed indicate that this yas not a criterion for establishing potential access routes. 2.·There needs to be a systematic decision-making process exp11citly laid out for determining an access route for the Susitna dams. This decision-mak1ng process should be straight forward so that agency participants can understand and effect1vely participate·in establishing proposed access routes.There needs to be a broad range of criteria established for determining the acceptability or nonacceptibility of various route alternatives.Information provided by Acres and their subcontractors to date indicates that Eric Yould 2 March 26.1981 3. 4. the criteria used to determine access.roads were eight in number and are roadway and railroad technical design parameters exclusively. It is the recommendation of the Steering Committee members that there are numerous other criteria which are critical and need consideration along with the technical road and railroad design parameters.I would refer you to an attached document entitled I1S u itability for Haul Roads"to give you an example of a more comprehensive 11sts of criteria that need to be incorporated in any decision with respect to access to the dam sites. There needs to be a clearer explanation and understanding of the decisions regarding the timing of building access roads vs.FERC approval for the project.We were advised by subcontractors that the timing depends on which access mode and route is determined. The time of construction and des ign of these routes varies from one to three years.The agencies on the Steering Committee need .ro have a better understanding of how these facts and assumptions interrelate to each other in order to make informed recommendations to APA. There are numerous specific decisions that will be required regardless of which access mode and route is ultimately determined the most appropriate.The location and development of these facilities could significantly affect the preference and recommendations from agencies.For example.identification of gravel sites. spoil sites.stream crossings;construction camp service and maintenance facilities will be needed..The members of the Susitna Hydro Steering Committee unanimously felt that it was important and necessary for APA to provide an understanding of how these decisions will be made and how a quality control system will be in effect to ensure that tasks are accomplished in accordance with approvals and designs. 5.The Susitna Hydro Steering Committee members in reviewing the March 6 and 20 meetings and discussing with subcontractors have determined that data gathering planned for this summer should be carried out on several access routes in order to make the final decision as to which one is most acceptable.To make a determination on a specific route with the lack of data/information that we are currently dealing with and then s~nd researchers and data gatherers into the field this summer to gather site specific data on only one route is of questionable utility and logic.The primary reason why this is questionable is because unless comparable data on several of the prime routes is prOVided,the agencies will be unable to provide comments as to which route is most acceptable. In summary.we see the gathering and analysis of data on several proposed routes as the rational basis for makingii:a determination as to which access route should be ultimately chosen. In summary.the Steering Committee wishes to ~hasize that it 1s willing and anxious to work cooperatively and expeditiously with APA in identifying and resolVing the numerous questions which need to be answered in order to make rational decisions with respect to access to Susitna Hydro sites.Once you and your staff have had an opportunity to review this letter,I would appreciate an opportunity to sit down and.discuss the specifics of these comments in further detail. Sincerely yours, March 26.19813EricYouid cc:Susitna Hydro Steering Committee Members R.E.LeResche Reed Stoops Al Carson.Chairman Sus1tna Hydro Steering Committee f4Iy 4.1981 P57oo.11.74 T.871 Sus 1tnl Hydroe 1ectri c Project Access Road Studies Mr.A1 Clnon.Chairman us1tM Hydro Steering CoIDD1ttee laska Department of Natural Resources 23 East 4th Avenue ' Anchorage.Ai{.99502 e are presently developing I.systematic decision-making process that can be utilized for access road selection and for other major decisions that will be made as part of the Susitna studies. The decision has been .de to obtain atr photos on all three major acceSs corridors.thus.el1minating the necessity of an ar1)'decision for a preferred corridor. Our decision as to which corridor or corridors will receive detailed studY will not be made until we complete our evaluation of overall objectives,selection criteria,and data base.The Steering Committee will be given the opportunity to review our selection process and recommendations prior to us making a final decision. Trusting this meets with your approval. Sincerely, acknowledge receipt of your letter of Mardi 26.1981.to Eric auld.APA.P1"'8Hntly.I Ut in the process of reviewing your COIRo> ments and reCOlllRendations.1 appreciate the Steering toan1ttee's 111ingness to work cooperatively with APA in identifying and resolving the nl.lll!!rous questions relating to access roads and other spects of the Sus1tna studies. WILLETT SWITTE fLAMB -/.A I;IATPEN-Y II 3l!".BERRY ---'~(fU'," 1-,;. J I'"('Hj)....../17 1f'1 IXi GILL /"-'1"-1'ILOWREYYV.qETZr-~r-~.\.k!\II HUSTEAD eaVE a W CHASE e v 7/1,:', Kevin R.Young KRY:db ..... ".. ,.... .- - - ALASKA POWER AUTHORITY April 15,1981 ~1r.Bill Lawl ~nce Anchorage Operations Office Envirolv~ntal Protection Agency 710 C Street . Anchorage,Alaska 99510 Dear Mr.Lawrence: Attached is a mid-point report on Susitna Hydroelectric Project.It is forwarded for your information in response to your earlier expression of in- terest within the context of the Susitna Hydroelectric Project Steering Coom1ttee. I have asked Mr.Allan Carson.the Chairman of that c0I1I1l1ttee,to forward meeting minutes to you and to ensure that you are advised of scheduled meetings. Sincerely, FOR THE EXECUTIVE DIRECTOR gav1d O~Wozniak Project Engineer Attachment:As noted cc:Allan Carson w/o attachment CONCUR: OWRAM ALASliA I:aOlVEn AUTUOIlITY MEMORANDUM \ \TO:For the Record DATE:May 1,1981 FROM:David D.Wozniak ~~SUBJECT:Steering Committee Mailings 5/1./£)'/ On April 23,1981.copies of the APA mid-yea;report and the Plan of Study were hand carried to USGS and AEIDC.Co~ies of the mid-year report were earlier mailed to other members of the Steering Committee.With this action.a11 member of the Steering Committee either possess or have accesstobothdocuments. May 8,1981 Eric Yould Executive Director Alaska Power Authority 333 W.4th Avenue)Suite 31 Anchorage)AK 99501 Dear'Eric: 279-5577 n:":Cl.:IVED :.:/'.'/1 ;\1981 -- .- The Susitna Hydro Steering Committee has reviewed the Alaska Power Authority's March 1981 Mid Report to Governor Hammond and the Alaska Legislature.Specific comments from the Steering Committe members regarding this report are provided below.In general,ho~ever,the Committee was disappointed that APA did not permit our review of this report.prior to its circulation,as several members have discovered factual errors in several locations in the text.and most have reservations about conclusions reached by APA regarding environmental feasibility. Dave Wozniak has assured me that.in the future.the Steering Committee will be included as reviewers of all APA documents of this nature on the Susitna Project •.and in particular I have been assured that the Steering Committee members will be provided an opportunity to comment upon the draft of the final feasibility report to the Governor and Legislature scheduled for March,1982. The following are specific comments on the 1981 Mid Report:- .- 1.There appears .to be a great deal of misunderstanding on the part of the External Review Panel (and perhaps others associated with th1sproject)regarding both the scope and the completion date for the feasibility studies.The feasibility studies currently underway will not,as we understand it,terminate in mid-1982 when the Application for License is filed with FERC (assuming the decision is made to file).Feasibility studies will in fact continue for several more years in order to gather sufficient environmental or other information' with which a reasoned decision can finally be made whether or not to construct (FERC staff alone will require a great deal more information than will be available in 1982 with which they can prepare a draft environmental impact statement). The March 20)1981 letter signed by five members of the External Review Panel refers to "•••feasibility studies •.• completion in April,1982"ann n •••present studies,supplemented by appropriate additional investigations,to their 1982 completion date.1I While "Phase I"may end in 1982)"Phase Eric Yould 2 Ma "'1981 II"will continue for several more years,as we perceive it. We suggest you make this point clear both with the External Review Panel and with the Governor and Legislature.We also suggest that,via your public participation activities,the public be fully and accurately informed about the length of time required to (a)determine whether or not to apply for a FERC license,(b)finally determine project feasibility,and (c)obtain a FERC license and actually begin construction. 2.The Steering Committee is of the opinion 'that the report is too much of a "sales document"rather than a balanced assessment of what is known to date regarding Susitna feasibility.For example,it is stated on page 7-6 "Whether positive or negative the overall change in the Cook Inlet salmon fishery will probably be slight."Recognizing the paucity of supporting data the committee feels this conclusion,and others like it in the Environmental Implications chapter,are premature. 3.Individual Steering Committee members have found technical errors in various places in this report.Rather than enumerate these detailed comments at this time,you may expect comments from individual Steering Committee members or their agencies in the near future. Finally,I have been informed that the External Review Panel plans to convene in Alaska in the near future.I request an opportunity for the Steering Committee to meet with the Panel,perhaps when they are briefed on this year's field studies.Also,in order to keep members of this External Review Panel appraised of future Steering Committee concerns and technical comments on the Susitna studies,we feel it appropriate to circulate to Panel members letters,memoranda,etc. generated from the Steering Committee.We believe the Panel members would benefit from Steering Committee comments,particularly sin~e they might not otherwise have an opportunity to gain insights into state and federal agency scientific/technical,regulatory,and public interest concerns. I hope you find these comments constructive.We will provide Mr.Wozniak a detailed outline of steering committee interests and concerns regarding the Plan of Study at our May 28 meeting. Sincerely, Al·Carson Chairman cc:Dave Wozniak Steering Committee Members ,.... ALASKA POWER AUTHORITY June Z,1981 Mr.Al Carson Chainnan Sus1tna Hydroelectric Steering Conmittee Department of Natural Resources 323 E.4th Avenue . Anchorage,Alaska 99501 Dear Al: Thank you for your letter dated Hay 8,1981 concerning the 1981 Mid Report and associated matters.Regretfully.heavy travel commitments within the office have sl<Ned this response somewhat.Nonetheless,it is important ttlat the points raised by you':letter be addressed. Our current schedule calls for the publishing of a very well developed draft of the final feasibl1ity study report by March 15,1982.I reaffirm our coamitment to provide this draft to Y~'J and fellow members of the Steel 'ng COUIDittee for revi ew.I tM nk there 1s some canfus i on,however. concerning other documents to be reviewed.111 principle,the Power Authority welcomes the Steering COI1IJIittee review of our various effort.... Unfortunately.we have not yet agreed as to the items worthy of Steering Conmittee review.As I have noted to you on several occasions.we would 1ike to interact with the CC81111ttee rather than continue the intenn1tt8nt, somewhat adversary contacts that have characterized our past discussions. If we are to be truly interac~ive.your cont:-ibut1on to defining the areas of interaction is essential.To that object1'fe,let me repeat my suggestion· that the Steering Committee~~t11izing the Plan of Study as its guideline, ident1fyspecific areas andlor events and the assocht"<l degree of depth with which they wish to be involved.Given a clear und£!rstanding of expected areas of interaction,.the problem of Steering ConInittee review or nonrev1ew of the Mid Report might not have occurred. Insofar as future project milestones are concerned.the effort currently in progress.variously called IIFeas1bil1t.Y Study"and/or "Phase In,.has as major objectives,deteminingthe technical and economic feasibility of the proposal t and.if feasible.generating the data necessary for a Federal Energy Regulatory Commission (FERC)license appltcation.This step 1$bounded by a Power Authority contract with Acres American.Inc •• a contract which terminates in m1d-1982.That date fs consistent with a pa.ge T~o legislatively mandated Po\ter Authority rccoITmlcndation to the Governor and Legislature by April,198Z on project continuation or abandonment. The underlying assumption is thnt sufficient information will be available by that time to r:mk.e a reasone'd and reasonable judgment on '....hether or not to submit the license application.(Please note that this is not a decision to "build"or "not build",a point I w111 address further on.) Strlctly speaking then~the "Feasibility StudytP 'iii 11 in fact tenninate in rnid-1982,by virtue of the contract terminating. If the mid-19tl2 decision is to continue with the Susitna Hydroelectric Project proposal.we will enter a period frequently referred to as Phase II.It \'iould be characterized by submittal of the FERC l1cense application,commencement of detailed engineering development.and contin- uance of a substantial amount of'1nvest1gatfons of the project area. including such subjects as fish resources.By mid-1984.it is anticipated the license application,as su nlemented and modified b the continuin investigations,will be approv.ven C approva"and a n er 0 other,lesser rE!9Ulatory approvals).the question of build or not bul1d wi1l then be referred to the State government.where a decision on con- struction will emerge through ,the political process.- Recent discussions with the EXternal Review Panal suggests that they are V-cry clear on this sequence o~events,and this S~~concept.(although worded slightly differently)was advanced in the Mid Report.Accordingly, I must conclude that both the panel and the public have been fully and accurately informed about the project flow.Certainly,there was no intent to be anything less than accurate.andint1mations to that effect warrant strong objection. I regret your letter arrived too late to accommodate a joint convening of the Steering Committee andth~External Review Panel.As a partial accom- modation to your request for such a joint convening,please let me note that the meetings of June 3-5~,19B1 are open to the public,and members of the Steering Comnittee are more than welcome to observe the proceedings. (The Cormni ttee \."a5 made aware of thi s 1as t week.)We agree \.,ith your suggestion that the External Review Panel be kept appraised of Steering Committee concerns and technical comments.and have no objection whatsoever to circulating letters.memoranda,etc.,generated by the Steering Committee. However,a review of such material indicates the only data generated by the cOrl!;}ittee to date are comrients to the procedures manuals,a letter concerning the access proposals,and your ~~y 8,1981 letter.Finally, with respect to a joint conven.1ng.we are certainly agreeable.I think we need further discussion to define format and attendance;for example, I am not sure that our geotechnical representative would gain greatly from comments advanced by the natural sciences community.Perhaps we will want to focus our efforts on the environmental representative.Dr.Leopold. Further.to be efficient (substantial expense is involved in bringing the Page Three ALASKA,pm{ER AUTHORITY '"'" panel members to Alaska and paYing their per diem)as well IS profesri_l,. 1 am sure you will want to give some thought to the structuring ~and.,....• content of your formal presen~ations.1 would welc~~continued dfal~: on thfs subject. Sincerely. David o.Wozniak Project "tanager .CONCUR:RAM EPY 02-V-81-TES-8.0August21, DEPART1UENT OF FISII A~D GA J\IE JA r S.HAMMOND,GOVERNOR 2207 Spenard Road Anchorage,Alaska 99503 ~~~)Ill&)(}t ~~XlX)qX~~~ Mr.Jeffrey O.Barnes Environmental Study Manager Terrestrial Environmental Specialists R.D.1 Box 388 Phoenix,New York 13135 RE:Anchorage-Fairbanks Preliminary Transmission Route Selection Dear Je.ff: Attached are the comments by Region II of the Habitat Division to the proposed Anchorage-Fairbanks Transmission Route. I might note that Sport Fish Divisionis Regional Supervisor,Russ Redick,indicated in a recent meeting that a State Division of Parks access and wayside development extending from the Parks Highway on the _ north side of Willow Creek to the Susitna River is envisioned for possible development if funding is approved the Legislature this next session. Consideration should be given to the potential impact of the transmission 1 ine to that proposed development,which is expected to receive heavy recreational use. The Su Hydro Aquatic Studies Team has no additional comments at this time. ;;+~ Thomas W.Trent Su Hydro Aquatic Studies Coordinator Telephone:(907)274-7583 cc:C.Yanagawa ~:~~g~~~der .-,VlEMORANDUM c9 z -:["-~I -1flrFrO--D. State Off\lask~~I-IE!>-£;• ""'"TO:Thomas W.Trent Su-Hydro Aquatic Coordinator Sport Fish Division Anc;:horage ....fROM:Carl M.Yanagawa W Regional Supervisor Habitat Divisi ~e~y:...--llH'AJhrmlnsk'i , .- DATE: FILE NO: TELEPHONE NO: SUBJECT: ·rr L-. Augus.t 6,198~./.''.9~/P :~~,.'..-.)'.'''~b' 344-0541,Ext.~l>.,..,.... :"l~)O~.,.~~~..~ .78~O/ol·v~~·.Anchorage~fa i rbanks ~B4;.r~cf . Prel iminary Transmission q ~Q~ Route Selection~o s Region II has reviewed the preliminary route selection for the prop~sed transmi~sion line and.submits the following corrments: -... In areas where the line approaches or infringes upon Susitna State Game Refuge,alignment should be adjusted to avoid areas utilized by moose and waterfowl.C1 earing and construction near these areas should .be scheduled to minimize disturbances to wildlife. - - The R-O-W segment frOin Cook Inlet·to Talkeetna especially ~east of the Parks Highway north of Willow should be cleared and encourag-ed to regenerate as moose browse.Between Willow and Talkeetna this'has the benefit of possibly halting the westward winter migration of,moose to the Susitna River.On years with heavy.snowfa11 as many as 200 moose have been- killed by motorists'and trains as they wander through the area.'In . addition,R-O-W clearing and construction must be scheduled to prevent conflicts.with moose and sport hunting activities. With respect·to stream crossings,most of the streams within the proposed corridor provide spawning and rearing habitat for anadromous fish.We do not expect any significant fisheries impacts from an aerial line, however,R-O-W clearing must be avoided at crossing sites to maintain watershed integrity and preserve riparian wildlife habitats. We suspect that there will be a great public outcry with respect to the aesthetics-visual impacts related to the proposed alignment,especially where it nears the highway,popular recreation areas and small co~u~ities. We suggest that APA conduct pub;ic hearings regarding the proposed '. alignment and delete or relign those seginents'of the route that are'. most objectionable.Most of our concerns can be met through use of. timing constraints,stream buffers,selective clearing,he1i~opter and/or winter construction. If you have further questions,please contact us. i1f£:.aa __"EtI I ft"E"·CcIYED ..;EPie l~ld,&ecutiYe Dir«w Alaska Power ~tty.m vest.fOVTth AYeme ~p Alasa ggscl Dear 'fr.lou.ld: The.~e of this le'tter is to t~t to the Alaska PtM!r Authority 'APA\-~..-..w...r:!••_-+-~.Al -~--i ~.a...-a'...~.......(SliSC)_\~z .....--.~~'I.f~~l~~H,T_""'"ectrlC ~teer'.ng '-UiiIP.!t ..Id..""""'I:._CCI' o:t"Hlng APA·s ~sals for ilCC$S to tne ~sed Susitna iiY~"sites. These ~s are in Te5poose to informatioo proyidt!d t.~sust fl""Cll t1IIO 4CCesS ro~te -.atings 'lritB APA and 'their-amti"A-Ctct'S:and tbe docu;ients ~re-j by APA cuntnctDf'$.and distribfrted durir.q these J!eetipgSr At t:ne October 20.,19tH ~t.1ng AflA ~~ttd SHSC C'f!i'et?nU by imvember 6,.1981..The 5HSC ~pp1'"t!Cia'~cs' tbe fact that APA c-cntlmA"d cleailed CQl2SidaratiQfi ami ~les ~sf,!Yer:gl ~Q;ess T'~te cp"tic.~s th1~year ,,"att~T t..~TDO.I31ng 0."1 a.single ~..e.. 'The Stlf-SC review lGefitifie-J four iU",?.,,;;of ~rn that merited ~tr""~~.\._:;r::,~ Thu~e four ~ce:I !$_:3.TNA ~1..It crttl1:l1.le of the studie!of 41:cess roo.l~lChlf;.lot io'l sQyid2 for amtt:l"J'l1i"E ,-C'~f(Yl, tion of t.~dam...J .·11.' i 1:2..<=,,",':..•..-.<-;2~1r.e.relatiOl'.ship be~t1..j~!jf access root.!con~trJt:t}i>}}.imdtr-"l';·~~'':'7 fee~i11 Energy ~qiiJttiry ~iis:ion (fERC)approv41 f\1.f'~<;_it.-~/u I f4'- 12 ~::: The relationship of aC'""~s ~~te d.~ision 4r'od ~es of'<i«.es:s:to g c ~_ rc';fian.d land use EWliigarsit ¥4Hc;les.-.-lit;;·__ 1--./-- Thl!-issues resultant frf;m la.nd sta:tu.s and lar.-d Oilmersnip .l.ffecl~~.)~-_ ~~~~~Irc~ },; Tt-e i!ssessment of C-Qrridor rcu'te oilt..."'r"natives should a;sre adEq"Liat.e-ly ~Sfi"-RR-;:" tt".e:pottttia.l ~c:ts of boM"'OW sites a~access to 't.hese sites.and trai1s-r ;-;.<! ~issiOJl 1.ine{~)mn:i!";g.Access corri~J'"S ~ich SErie a _~T7 Ol"triple.ijurPo~~;J-;i "cc in f"e9:aro "to ti'.ese Qtrif!"project acr!Ss r:~would be fnghTy des1rab,e f,qm-t:H·.. decis1on-m~ing crite..-ia..I-!it~§Q'-!h :.;.~{i'~-~c.- .~~;'A j.---.l-;---;-=I i;~-;- r·~Li !.::;:U I ~[:::7. to--'-t ~-. .- - .... ..- The ~c:ess preferences,expressed below pertain to the ~emmt1 loe.tt1ons l::ited.for tnt!comdoTS and ire based upon the envll'tmiili!ntAl dA.t4 Gr4...eonc 1u- sian:;contained .'+envirotmerita.l dooEGf!l1ts prepared for SUbU$k ·2.~lO. ACc.tiS Road Asses~t~It.dQe$not represent.our .--rs.euent c a pait.lcular 1 ~le-'!ride arMdcr"as prescnted~ '!be SHSC ~w1~\the Terrestrial fn'liroJ1fil!ell'tal S;Je€;'ialists.lne._pOS-i- tion that accesi ita tM AlasuRaflraa4 to Gold Cr'ea is·environeeritally pn::- ferale.bilr1*f access to at least Devil Canyon WQYJd alienate the need for it st.i.91ng area ilt Gold.i:.r'eek and.the CQI1Sequent IiullI4nllCtiVitl~l4r.d ~•.fuel iiiHls.7 ~W other iIIlpacfs Oft the Gold ~~.~iJe··recogft1z.e4 t1\at •s:t:ilging ilrea.ilt Detil Canyon ~ld ·be required in ~.cu-e-~The use-·Gf tiris an!ill as tnt! terminus of a raHi"aila~f'$to-"eiJgTal:deal of SI!fi.$e~Additicr.aH,.tile feel 'tJat the .~.5ide ~-m.:-Q11d "-eek to Dr!vH Canycn ispreferaole since a traH illready e:ists:~.f'nII Devil CanJQII to IBtana.w..PN4er & rou.teOn the north $lQe of the Si,rsi~.River...lit the October lO..1981 ~:tl~ me 5H5C 1IiIlS lafonr4 bY i'Ir..Dilv1ct wozn1ak of N'A th-.'t.~were net (2j ~ddfUOGll ra.tlrcad :'ClttejllOde op't"icns (a total of 10:)..If feaslule ,.~­ ~ny pn!fer "nil IIOC!£of access to-and within l:he project site• The Sb"SC id2nttfi~three (3)aw.t~ta.n.Y sensitive .reus that should be 4l\toide4.Those ire~ 2.T~route crossing the Indian River and tlu"ooqh ~dam1s to t.~Parts iitg~y~ 3.The mute on fr.e:sooth side Qf t.~Susitr..1 Riv\tr fnm Dans Cdnyoo to tile prtiPQsed \ia.LiUjA c..sm S 1tQ:. ~...~l··-t"-+b",~.~...-~......t:'l~~A-I:"A .-......,...l.......~lI!p.-F-rl1..eYa Ud I nq \-lr.:"<&0:::._:).~roo.!,"","..e.~;".I C4'i p~'C ..~~....fO~.",",...en U¥\-10;;ru:Ii 40"':' tr-..s conf:nc"'L.Ors"the Steering Ca!irzittee questions the validity af t.."li!pcwer-::Jfi- 1int!in 1:r"93 assl.liiiPtior./~te.1t.~~1ie've got to hurry up and put in '..0'£road to E2.t the 1S93 daa.dli['.e~iGJProach appears"'f'ro!i currently available repor~ and t..~briefings received by the Susitna Hydroelectr-tc Steerin9 Calr~1 ttee an lkUiber 20,.1981 t-to poirrt tL-;ward tiE necessity of a pigneer ro...=d c.onst:t-~tf;d before d f£RC He....c..nse 15 9r~nte<iw or selection of an ilpp.s:1nmt.ly enviro~n~ny ut',a(;ceptable Def'A~1i Higr:-l!I!faY ;;ICC-55 rot..-te .. local utilities a~not approJichinq c-onstruet1on of fl.project the magnitude of S~sitr.a in 1993 as a fo~one conclusion arli1 a.re ~klft9 Co~t1n9'::-t.-c.r ~}liins to meet projected pm;cr r.eeds£6as and COdl '1£neriit~~~r ",-ptions are being eA~ined~in i1...1d1t1on"fEiiSibility studi~are cu.!e.ntly being underuken hy t:'::'2 U.S.Amy Corp~cf Er.9inettrs and t.fte Ju°A at nu=-!::--ous pa~ntial hydT~lectric generatir"1 ~ites£~ni.t hHt-el t ~l;:dric ?r;rM;r A1tE'I1".ative Study should provide inslaht into add'{i.lo~-T .n.c:;..H m (',1""en<'-..As sycn~we beHeve: ..ish t.~1993 &deddHr.e~for-p:mr.:r"-ml-Hne fl""all Susitna £Sly no't be t.f'>.a:t fin:!~d i~erative.Thus the SHSC (j.'}es r,ot believe th@ 19:13 ~dHne should const..n~in 'the O'I~an decision ;:-,aking prne.2SS Af:-rl t.~GT1:1erb'proYress jjf various sWdies an project feaSibility and snvirorESttal ~r.acts.Pe:rmittir'9 iInd resource age-r-.c.1es.i-nc.Judlfl9 f£RC.~h<J!.ild be i!Xp£ded to Hnk ~pioneer read to tf;~ vye-an projet.'t. Publ1c auess tu the da:n sites and t.brough the Upper Susitr.4 Yaney is canpl~ana i CQntroY('rs1al subjee;t.ar.d we ~1ieve this issue S&hQuld be 9~ve!l thorough evaiuation in the route $tJecUon process..How C01\~tructioo~related access is obt41ned to iI greilt ext.ent determines tone PTOject·l"'elated wildlife clnd soc1~i~impacts.The APA has been ~olic1ti"g the views of local residents (T41keetna.Trapper Creek ..etc.)in reqard to the access question.The mjority of resfdents wnt to minimize iqtacts to both thel~camwnity an<.1 tJ.e Upper Susitr'.a Vdley_The APA.has solicited the v-1cws of the·state 4nd federal resource igeneies.It has been the prv.dQlAinant vlew of these agencies.which represent. pUblic im:eresu on Ii state or n.tional le.vel;t.hat projett~related wildlife impacts should be limited to the Jj1XilUR extent practicable.In addition.the APA has expressed the desire ~~'hl'i1:_the.option!.,for future public access. We'believe that these views JlM!$h..M~i.drt9 impact-s ilnd maximi.ting options tor future publ ic access an be i!chi~.ved 11.)'J:OJr:icking;po to the e.xteot possiblE!y the status quo.for exlBp)c.to provide fun publjc 4C~SS through a road systslh forecloses the:future option Of maintaining the:eXlsting tharacter of the upper Susitn4 valley .. Use of rl1',H a.s tfle access n:Jode tncreases the potential for mana.gement a.nd control of sQc:fOeconanic and enviromtenta'l impi%C:ts~~h':ilzed rail use proYid~S for the fo l1ni.ng advantages over road access: 1...IM'nta1ns a ~x.imtl!l.range af future decision options. 2.~'1'id~~fut"control of WQr~\"impacts on )oc~l t~Jnlt1e~and wild- lifE:.. 3..Decr't!~5es the potential of ftaz.~T1iOiJ.S :r~t.eTii31 spills due 'to adver$e ~ther conditioft$and multiple handling~ 4.Disturbance t.o wi ldl He adjacent 1;0 the route can lie ~ft easily controlled. 5.Di~t ~cc~s.s t\9ht-of-way relate<:!habitat losses can ~stqni ficantly l\mf ted .. eriefl)'tm'!1and status of the ?mject anN!haS not changed significantly within the last year.There al~severa1 tom~lex pT'u{)l~.s conccrnio9 land status that ~~ve been bruught to your a.ttention by BL~_ Thankycu for the O~lp01"'tunity 'tQ -re:\!iew imd cOtirr.ent on the Ar.ce~s Road ;"~5.tssment dOC~-elitS.we look fQJ"W{!n!b.2 rc.-ee1vlng the final ver.iiQ1J of these doc~enb after flove1iber 15,19a1~ami a.nticipate prov1d1fi'<J additjo:Jal recom- IDe:'ndiitiQns into this dedsiQfi-making proce~s~ sIncerely" P.l Clirson;Chai'f'i!'.an $usitna HYQro:lEctrlc steerto9 (~~itte~ cc:o.WoZniG~9 ft~A Steerfr~COffrnitt~~~nbers ~L StOOy~ r----- •T"".'1-.... November 9,1981 P5700.l1.75 T .1258 -WILLETT WITTE BERRY HAYDEN LAMB 1"'"LAWRENCE SINCLAIR VANDERBURGH 1"'"...,~. .....J ~ CARLSON FRETZ-JEX i LOWREY SINGH F"" HUSTEAD BOVE , ~ j CHASE I ./ V':;;//,. ,.,.. Mr.John Rego . Bureau of land Management 701-C Street " Anchorage,Al aska 99501 Susitna Hydroelectric Project Transmission Corridor Report Dear Mr.Rego: As you know,Acres "AmerJcan,Incorporated is under contract to the Alaska Power Authority to conduct a feasibi 1 ity study and prepare a Federal Energy Regulatory Commission (FERC)license application for the Susitna Hydro- electric Project.The scheduled date for submission of the application is in June of 1982. Federal law and FERC regulations require that the reports supporting the FERC appl ication be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.Thiscoor- dination must be documented in the 1icense appl ication •. A great deal of coordination has taken pl ace at .agency staff level s by dir- ect participation in studies or by participation in committees and task groups.This input,however,has been prim.arily by staff and may not nec- essarily reflect the views of the agency.For this reason,weare conduct- ing a parallel formal coordination process,by requesting agency comments on key study outputs.The plan of stUdy was the first document coordinate<il in this manner.Over the next year,there will be several more.This par- allel process will affect the other coordination activities of the study. At this time,we request that the Bureau of land r~anagement review the attached Report,"Transmission line Corridor Screening Closeout Report", particularly in the areas of aesthetics,land use,and land management. t "ACRES AMERICAN INCORPORATED Development Selection Report - 2 November 9,1981 Your prompt attention to this matter will enable us to continue planning the best possible development for all interests.A response within thirty days of receipts would be greatly appreciated.Please send a copy of your comments to: Mr .Eri c Youl d,Executive Director Alaska Power Authority 333 West 4tll Avenue' Anchorage,Alaska 99501 Very truly yours, JOL/.MMG:jgk cc:Eric Yould,Alaska Power ACRES AMERICAN INCORPORATf::u jiJ,~)/)VI~tAuft '-~~John D.L/wrence IT Project Manager /Authority)' Preceding letter Sent To: ·Mr.t.ee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer AK 99645 Mr.John Rego Bureau of Land Management 701 C.Street Anchorage,AK 99501 Mr.Tom Barnes Office of Coastal Management Division of Policy Development and Planning Pouch AP Juneau,AK 99811 Mr.John E.Cook Regional Director National Park Service 540 West Fifth Avenue Anchorage,AK 99501 Mr.Ernest W.Mueller Conmissioner Alaska Department of Environmental Conservation Juneau,AK 99801 Ms.Lee McAnerney Department of Regional Affairs Pouch B Juneau,AK 99811 Mr.Ronald O.Skoog Conmissioner Alaska Department of Fish and Game Juneau,AK 99801 Mr.Keith Schreiner Regional Director U.S.Fish and Wildlife Service 11011 E.Tudor Road Anchorage,AK 99503 Colonel lee Nunn District Engineer U.S.Army Corps of Engineers P.O.Box 7002 Anchorage,AK 99510 Mr.John Katz Alaska Department of Natural Resources Pouch M Junean,AK 99811 •Mr.Robert Shaw State Historic Preservation Office Alaska Department of Natural Resources 619 Warehouse Avenue Anchorage,AK 99501 Regional Administrator U.S.Environmental Proection Agency 1200 South Avenue Seattle,WA 98101 Mr.Robert McVey,Director Alaska Region National Marine Fisheries Servite P.O.Box 1668 Juneau,AK 99802 DEPARTMElWT OF N&I'I.JRA.L RESOIJRCES DIVISION OF PAlla RECEIVED JAr S.HAMMOND,GOVERNOR 6'9 WAREHOUSE DR••SUITE 210 ANCHORAGE.ALASKA 99S01 PHONE:27441J1.ALASKA POWER AUTHORITY SUSITNA F;0,00 DL.I ...:,:.... Re:1130-13 DEC 14 1981 December 4,1981 ACRES AmtJJJliiUi lNt:DaeORATED Dear Mr.Lawrence: John D~.Lawrence Project Manager Acres American,Inc. The Liberty Bank Building,Main at Court Buffalo,New York 14202 _...:!'~l -i1C~~==tJ~S-1 .1 P·::...·~i. E~;'j W:have reviewed the 1980.reports by t~e University of.Alask~Museum de TIFg -S:-l T -- w1th the cultural resources of the Sus1tna Hydroelectr1c project area.'fh -ow L report documents the survey activities conducted during 1980 which adeq -.._-- accomplish the tasks outlined in the proposed work plan.The sampling designed on the basis of geomorphic features and known use areas seems surpassed our expectations of site incidence in the area.The report s .that the first level inventory was very competently conducted and recor d The second year activities as outlined in the procedures manual was acco~ plished in the 1981 field season according to information gained throug verbal conunl.lnication with the principle archaeological investigators. understand that the field research strategy was changed slightly from th --j expected due to information gained during 1980.These changes appear to~~c-__~--~ more directly addressed problems which surfaced during the course of analysis of the 1980 data.A final review of the 1981 results and reports will have to await receipt of that document. We feel that the steps taken thus far in the cultural resource management of the project have been excellent and one of the few instances of adequate lead time.We would like to make the observation that the work thus far is only preliminary to the work yet needed for the Susitna Hydroelectric project. Reconnaissance and testing of yet to be examined areas should continue.The clearances of specific areas of disturbance provided as additional survey by the Museum should indicate the continued need for clearances of ancillary projects which could affect cultural resources.Also,a formal mitigation plan for those sites to be affected by the project must be formulated.Once definite decisions on the route of access to the project area from existing road systems are made,those'access routes and material sites must be examined for conflicts and needs for mitigation.Issuance of a permit by the Federal Energy Regulatory Commission should and probably will include provisions specifying under federal law the need for such protection. John D.Lawrence December 4,1981 Page 2 - If you have any questions regarding our comments contained here,please call us.We look forward to receiving the report on 1981 field work. Sincerely, Chip Dennelein Director By:.J..L.....j~-..J.A.VUSha~ cc:Dr.E.James Dixon Curator of Archaeology' University of Alaska Museum University of Alaska Fairbanks,Alaska 99701 Eric Yould Executive Director Alaska Power Authority 333 W.4th Avenue . Anchorage,Alaska 99501 DR:elk RECEIVED DEC 28 1981 1200 SIXTH AVENUE SEATTLE,WASHINGTON 98101 REPLY TO MIS 443 A"N OF: U.S.EN V I RON MEN TAL PRO TEe T ION AGE N C Y REGION'X DECZ 1 1981 John D.lawrence Acres American,Incorporated The lioerty BanI<Building Ma in at Court BUffalo,New York 14202 SUBJECT:Susitna Hydroelectric Project,Summary Annual Environmental Report-1980 and Transmission line Corridor Screening Report Dear Mr.Lawrence: Thank you for sending us the above reports for our review.We have also received the Development Selection Report and will be forwarding our comments to you on that report before the end of December. ALASKA POWER We appreciate the extensive coordination effort and the opportunity to AUTHORITY SUSITNA revi ew and comment on Susitna reports as they are prepared.I further ~--·--------~appreciateyour attempts to ensure that the views of the Agency are FILE P5700 adequately reflected in thi 5 process.Whi le we have been coordinating -'.././,with the Sus itna Interagency Steeri ng Committee,our budget restrictions S~QUE~C~NO.have limited our active participation more than I would like.In this r.)"J/'regard,it would be extremely helpful to us if you could provide us an I :loverview of your consultation plan and the schedule for future reviews. z ~~i ~~,This will better enaole us to give you timely comprehensive comments on ~I":§~I{~em~;~~ous segments of the study,with the overall project perspective _1 ~:;';~,I __EPA is particularly interested in information on wetland mapping,water !~.';"~l __quality and water quantity modeling and project alternatives.The 1980 _t_:-:~·''Z.J-.:~Environmental,Report appropriately points out the inte,rrelationships and i~'1'1Y1f importance of these areas to wi ldl ife survival and downstream fish -~!I .ecology.However,it ,does not cover EP,A'S areas of interest directly.-'-11 -J"::;--\'we,'woul d 1 ike to review the reports on these SUbjects when they are ---_...::.---av ai 1ab 1e i I PC HI'• --r:::~5i -;:--!-;',r-!\----1<~,--;-.-1-'I'-r',:;:··~I-·1,.\: --i-H~-CI -1----- >.1ml1&i-~~--R~~ -1-''- .... - .- 2 We support the empnasis in the Environmental Report and related studies on identifying ways to minimize the environmental impacts of the Susitna project.In particular,selection of the access route and type of access isan issue witn long term environmental consequences wnicn offers many opportunities for minimizing impacts.EPA supports tne concept of minimizing impacts Dy use of a single corridor for both access and trans- mission needs,as pointed out in Dotn tne Transmission Line Corridor screening Report and the Environmental Report.We encourage you to incorporate tnese kinds of suggestions from agencies and the Steering Committee into the project selection,construction and operation plans. SUch commitments will certainly positively influence rev;ewsof any FERC license application. We have some concerns with the conclusions aoout the Central Study area in the Transmission Line Corridor Screening Report.There appear to be different opinions on the ~nvironmental consequences of selecting Corri- dor 1 versus Corridor 14.We feel that additional areas should be . included in future stUdies of the central corridor,to~rovide a broader data base from which such conclusions can be drawn.More specifically, in this area,Corridor One (ABCD),which roughly follows the south side of the Susitna River,is the recommended corridor based on Acre1s techni- cal,economic and environmental criteria.Corridor 14 (AJCD)follows the same route as Corridor 1 from Gold CreeK to Devils Canyon,but crosses to tne north side of the Susitna River for the section from Devils Canyon to the Watana dam site.Corridor 14 nas tecnnical and economic ratings as high as Corri dor 1,but was not recommended because of environmental and land use conflicts in segment CJ.On solely environmental grounds,it appears that an access route similar to Corridor 14 is preferred to Corridor 1 by ooth Terrestrial EnVironmental Specialists,Incorporated (Environmental Report page 73 and 82)and the Susitna Hydroelectric Steering Committee (letter from Al Carson,Chairman,to Eric Yould,dated November 5,1981.)Therefore ,the areas of the central corridor to be further studied should include the north side of the river between Devils Canyon and the Watana dam site to encompass segment CJA as well as segment CSA. One reason for the different conclusions regarding the enVironmentally preferable route oetween Devils Canyon and the Watana Dam site may be the Environmental Report's and the Steering Committee1s identification of the most environmentally sensitive areas,wnich then have tne nighest priori- ty to be avoided.It may be desirable to use a similar approach during the more detailed route selection stUdies,especially in areas where wetlands must be crossed.Identifying and-then avoiding primary and secondary impacts to the most valuable wetland habitatssnould be an important part of the more detailed studies of all three transmission study areas. 3 We appreciate tne opportunity to review tnis report.Please contact me or Judi Sc warz,of my staff,if you would like to discuss our comments. We can be eacned at (206)442-1266 and (206)442-1096,respectively. Eri c·Youl d,Al asK a Power Authority Al Carson,Department of Natural Resources January 4,1981L P5700.11 .91 T.l~90 e~AV •John R.Spencer ~.'j~/,.,..xeg1onal Administrator~.7 7 -,S.Environmental Protection Agency,.:00 X iW·0/I 00 Sixth Avenue ~.._NClii cattle,Washington 98101 NCI.;UA ANOEA8U.PlOM ..;""[!!ar Mr.Spencer~ -f Sus1tna Hydroe1~ctr1c Project Formal A6ency Coordination 1~R.LSON rnank you for your letter of December 21,1981;your constructive 11:):...----<:iIJ'oggestions are very much appreciated.I will attempt to respond ~l'leY I...,the issues you raised: "OM STEAO ~1.I am enclosing a description of our formal agency coordination plan,indicating which agencies will receive which reports. Regarding schedule,EPA will be receiving the following reports on or around the following dates: a)Fish and W11dlifeMitigation Options -January 1982 b)Instrum F1 ow Study P1 an -February 1982 c)Susitna Feasib11ityStudy -/t1arch 1982 Under separate cover you will be receiving an invitation to attend a meeting.in Anc~orage on January 21,1982 explaining our Formal Agency Coord1naa;on Program. 2.Wetland mapping has been conducted as part of the study. For your information,I am enclosing the 1980 Plant Ecology Summa~Report and a set of vegetation maps.All wetlands within the proposed impoundment zones (includin9 a one half mile buffer)and within known borrow area were mapped,utilizing the new U.S.Fish and \11ldlife Service Classification (Coward1n et.aL 1979). Mr.John R.Spencer January 4,1982 page 2 3•.Project alternatives are discussed in the Development Selection Report which you have received and will be disaussed further in the Feasibility Study. 4.Water quality issues and water quantity modeling results will be found in the Feasibility Stuety. 5.Following selection of the access route.the trans~ssion line corr1dor in the central study area has been expanded (as indicated on page 7-4 of the Transmission line Corridor Screening Report)to include a larger area on the north side of the Sus1tna River.This will result in a single corrddor being used for both the access route and the transmission line corridor.This was done both to !educe impacts via access and to avoid the large wetland areas on the south side of the Susitna River. 6.Transmission line routing studies are currently being conducted. Wetlands is a parameter in the selection process~I think you can appreciate,however.it will not be possible to avoid all wetlands in the area,simply because there are so many. Again,thank yod for your comments. let me know. ~1rftG/jh .cc:E.Yould,APA If you have further questions,please ""'1 Sincerely yours, ~/ John D.Lawrence Project Manager December 31,1981 UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National,Marine Fisheries Service P.O.Box 1668 Juneau,Al,aska 99802 Mr.John D.Lawrence,Project Manager ACRES American Incolporated Consulting Engineers The Liberty Bank Building Main at Court Buffalo,New York 14202 JAN 04 1982 ACR;;..;"lIiLrUti#\l~h'bUKfURATED - I~ ~SKA POWER AUTHORITY i 5USITNA St.QUENCE NO. /_.'-'),:"?,-'/ Dear Mr.Lawrence: We have received the Susitna Hydroelectric Project ~nvironmental Report prepared by Terrestrial Environmental Specialists (TES).We have limited our review of this series of documents to those concerning the fisheries studies,i.e.,the Summary Annual Report and Fish Ecology Annual Report. The presentation of 1980 work done by TES towards assessing the impacts of development and operations of the project on the fishery and proposing measures to minimize or mitigate adverse impacts was reviewed without substantial comment,as much of it was very preliminary.Also,no review was made of the 1980 fish ecology program due to delay in pub- lishing the detailed procedures manual.In addition to '~he lack of substantial information presented in these reports,we believe the timing of this review request makes an in-depth agency review inappropriate. The main benefit derived from this review would have been to allow changes or redirection of efforts to be made in the 1981 field studies.However, as of this date,the 1981 environmental studies have been completed. We look forward to receiving the 1981 Environmental Studies Annual Reports, as these documents should provide the basis for our review of the draft Feasibility Report. ~~.(~--J.,v~j,\ i./ Sincerely,......_J..'~--$--df?~ /Robert •McVey (/r,Alaska Region IN REPLY REFER TO: WAES United States Department of the Interior FISH AND WILDLIFE SERVICE 1011 E.TUDOR RD. ANCHORAGE,ALASKA 99503 (907)276-3800 Mr.Eric Yould Executive Director Alaska Power Authority 334 W.Fifth Avenue Anchorage,Alaska 99501 Dear Mr.Yould: Mr.John Lawrence of Acres American,in his letter of November 9,1981, requested that we review the Transmission Corridor Report.We offer the following comments: .•NJIlBtfA il'lbWIiR ljIIlJrHORITY $!~rlrN'" !RUE P5~ ..11.~.-7. SEQl1ENCE ~ Fd. Although we realize that the Anchorage-Fairbanks Transmission Intertie was assessed by Gilbert/Commonwealth and not Acres American,the two studies need to be fully compatible,coordinated,and unified in a single document for submission to the Federal Energy Regulatory Commission (PERC)• The conclusion of the Intertie study was that it is justifiable in the absence of the Susitna Hydroelectric Project.However,the Susitna Project is not viable without the Intertie.In that we anticipate reviewing the Intertie as a component of the Susitna Hydroelectric FERC license application,we believe it should be included in the pre-license coordination process. The extensive public participation workshops undertaken for the Intertie were well done and provided for an effective interagency and public dialogue.We highly commend the Alaska Power Authority (APA)for that program.We recommend that a similar effort be undertaken for the Susitna Transmission corridors selection process. Land ownership is a potential major issue and needs to be fully explored. It is not evident from this report that a sufficient effort was expended. The list of authorities contacted (p 8-3)does not list representatives of either the Bureau of Land Management or the Alaska Department of Natural Resources,the principal state and federal land management agencies. I 1"15 :E Di ~Il:ii i=0 t;iub- e !:0 -"" DeW Remote lakes,such as those in the Matanuska-Susitna Valley,are utilized by trumpeter swans for nesting and rearing cygnets during summer and fall.Recent data indicate that continued development and disturbance on lakes used for nesting is causing birds to abandon certain areas. Selection of a transmission corridor should be accomplished cognizant of the habitat requirements and movement patterns of waterfowl and other migratory birds. JI--f--lt'~;;;"":";;.I.-c':..+....H" Mr.Eric Yould Page 2 As required by the Endangered Species Act (87 Stat.884,as amended),the FERC,or their designee,should formally request a list of threatened or endangered species.from this agency.If the list indicates that these species are present in the project area,FERC is required under Section 7(c)to conduct a Biological Assessment.This assessment would identify any listed or proposed threatened or endangered species and discuss potential project related impacts~The assessment is to be completed within 180 days a.fter receipt of the official list,unless a time extension is mutually agreed upon.It should be noted,that this work toward the assessment may have already been completed through your previous investigations,and should be included as part of the Environmental Impact Statement for the project.In any event,no contract for physical construction may be entered into and no physical construction may begin until the Biological Assessment is completed. If the conclusions drawn from the Biological Assessment indicate that endan- gered or threatened species are'likely to be affected by the construction project,FERC is required by Section 7(a)to request formal consultation. Management of the transmission line right-af-way (ROW)could result in positive or.negative habitat value impacts.In certain situations clearing of the entire ROW width can.be undertaken to enhance moose browse.In other places minimal habitat disturbance maybe the most appropriate management·.Once transmission corridors have been .agreed to,discussions as to appropriate habitat management practices should be initiated with the FWS and the Alaska Department of Fish and Game (ADF&G).Clearing for the purpose of enhancing moose'browse should only be done after an ort-ground evaluation by the ADF&G and Alaska Plant Materials Center to ensure that vegetation within that corridor can be enhanced by clearing. Where the proposed alignment follows the existing highway,railroad,or utility corridors,the potential for disturbances to wildlife habitats would be minimized.Access to the dams should be fully coordinated with transmission line routing.Access corridors which serve a dual purpose in regard to project access needs would be highly desirable from several decision-making criteria. Public access to the damsites and thr~ugh the Upper Susitna Valley is a complex and a controversial subject and we believe this issue should be given thorough evaluation in the selection of access routes,mode of access,trans- mission line routing,and method of maintenance access for the transmission lines.How construction-and maintenance~related access is obtained to a great extent determines the project-related wildlife and socioeconomic impacts. Construction and maintenance of transmission lines should not provide for additional public access aver that provided by the dam access route. We concur with the report conclusion that of the three corridor alternatives presented for Healy to Fairbanks,segment ABC is the most acceptable.Our preference would be for the transmission line to closely parallel and when- ever possible to share the existing Healy-Fairbanks transmission line ROW. Also,we believe that an additional alternative,that of sharing the railroad ROW,should be evaluated. We concur with the Acres American position that segment AEFis the least desirable alternative of those presented for the Willow to Anchorage Mr.Eric Yould Page 3 segment.We also agree that segment AB would have extensive adverse environmental impacts.However,we believe further study should be undertaken to evaluate corridor options from Willow to Palmer which are closely aligned with the highway or other existing ROWis. Mitigation for transmission line construction and maintenance impacts would need to be incorporated into the overall mitigation program for the project.In addition to recommendations emanating from aforementioned points we would expect recommendations such as the following to be incorporated into the plan: (1)Should any eagle nest be found in specific siting of the iine,a 330-foot windfirm buffer would be established around the nest trees; (2)winter construction would be used in wetlands to minimize adverse impacts and in the vicinity of rivers so crossing can be by ice bridges; (3)helicopters would be used to construct and maintain the transmission line in areas not easily accessible from existing roads,trails, railroads,or planned ground access for which the primary purpose ~ould not be related to the transmisson line; (4)where overland maintenance access is adopted,such access would be minimized to no more than one route between major stream crossings or other geographic barriers;and (5)lOO-foot-wide vegetation buffers remain along all streams and rivers crossed by the transmission lines. Specific comments: 1.2 Existing Transmission Systems in the Railbelt:The implication of including the Glennallen-Valdez transmission system is that the Susitna Hydroelectric Project would serve this area.If this is the intention, then transmission line corridor alternatives to interconnect with the Glennallen-Valdez system need to be evaluated and circulated for review. 5.6 Description of Corridors (c)Northern Study Area (i)Corridor One -Healy to Fairbanks via Parks Highway:Paragraph 4. We do not believe that the option of closely paralleling and sharing rights-of-way with the existing Healy-Fairbanks transmisson line should have been dropped from further consideration prior to public and agency participation. Table 5.1 Technical,Economic,and Environmental Criteria Used in Corridor Selection:Additional environmental selection criteria should be:minimize wetland impacts;minimize river crossings;minimize visual,esthetic impacts; minimize impacts on natural systems;minimize erosion;and minimize impacts on existing life styles. Mr.Eric Yould Page 4 6.4 Reliability -Access:The proposed construction and maintenance access needs to be presented.Also a discussion of the proposed method of construction for the different segments. 6.5 Screening Criteria (a)"Technical Screening Criteria (i)Primary Aspects:Topography:.Steep terrain would increase erosion potential and would thus be a negative environmental factor. (ii)Secondary Aspects:Vegetation and Clearing:Heavily forested areas need not be cleared.Selective cutting and topping of trees are environmentally and esthetically more acceptable.Habitat modifica- tion to enhance values for target species should be thoroughly evaluated.Also,clearing of bankside vegetation is not generally considered an acceptable procedure. (b)Economic Screening Criteria (i)Primary Aspects:Right-of-Way:Paragraph 3.Refer to comments above (6.s(a)(ii)}. (c)Enviroumental Screening Criteria:Enhancement opportunities as well as potential negative impacts to fish and wildlife resources should be evaluated in relationship to habitat modification.In addition, .r~fer to comments above ('rable s.l)."".- (ii)Secondary Aspects:Length:The consideration that the longer the transmission line the greater the environmenal constraints is not borne out by experience.Minimizing adverse environmental impacts can usually be achieved by closely paralleling or sharing existing transportation or utility ROW's.This rarely results in the shortest transmission line. Soils:It should be recogni~ed that scarification of the land would not be considered an environmentally acceptable procedure. Cultural Resources:Contacts should be made with the appropriate state and federal agencies.Contact should be initiated with the National Park Service and the Alaska Department of Natural Resources. Vegetation:Proper timing of construction would help to minimi~e impacts. Fishery Resources:Refer to comments~mmediatelyabove.Secondary impacts related to increased access also need to be examined. Wildlife Resources:Increased access could have serious secondary impacts such as increased hunting pressure and increased human! wildlife cdnflicts. Mr.Eric Yould Page 5 7.Conclusion~and Recommendations:The AnchQrage-Fairbanks Transmission Intertie study should be fully integrated into the Susitna Hydroelectric Project Transmission Line Corridor report.The entire package should be circulated for public and agency review. Thank you for the opportunity to review and comment on the Transmission Corridor Report. Sincerely, (l,j}f7 1'"').~....~~~~:~gional Director cc:FWS-ROES,WAES,NABS Quentin Edson/FERC NMFS,EPA,NPS,BLM,USGS,ADEC,ADF&G,AEIDC Carson/ADNR Lawrence/Acres American April 14,1982 P5700.11 .71 T.1647 Mr.John A.Morrison Acting Assistant Regional Director U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,AK 99503 Dear Mr.Morrison:Susitna Hydroelectric Project Transmission Line Corridor Screening Report ~2. .- 3. ..milAi ,~ "'"I Thanky~u for your letter of January 5,1982,to Mr.Eric Yould,commenting on the Transmission Line Corridor Report.The flurry of activity in producing the Sus1tna Hydroelectric Project Feasibility'Report has delayed this response for whfch I apologize. I will attempt to address,in the same order.the issues you raised in your letter: 1.The fntertie is a separate transmission line and does not require an FERC license.The intertie will be constructed,operating,and carrying non-Susitnagenerated power prior to completion of the Sus1tna Project. The Susitna Project will only require additional of lines to the existing 1ntertie right-of-way.We are currently discussing with FERC if these new lines will be under FERC jurisdlcation. The transmission line route selection is not be1ng addressed through separate meetings but through the public and agency meetings ocaurring in March and April.The results of these meetings will provide input to thedec1sion making process as to final route selection • Land ownership by major category was provided for the entire trans- mission line stUdy area on maps developed by the resource planners of CIRI/HN.This material was utilized in the corridor screening and route selection process.TES discussed the location of the transmission lines \'/ith Art Hosterman and John Rego of BU1 and Dean Brown,Michael Franger.and Linda Arndt,among others,of DNR. 4.ADF&G and the U.S.Fish and \~i1d11fe Service were contacted during this study.ADF&G was provided a copy of the preliminary routing study and their comments incorporated in the final route selection.Bruce Conant of the u.s.Fish and l'Jlld11fe Service in Juneau ,who conducted recent swan nesting surveys.was also contacted and the information provided utilized in the corridor selection. Hr.John A.Morrison U.S.Fish and Wildlife Service Apr i 1 14,1982 - 2 5.With regard to endangered species,ADF&G personnel were contacted to obtain information on known location and habitats of these species within the study area.The corridors reflect consideration of this data.FERC will conduct the Section 7 consultation process. 6.Resource agency requirements regarding right-of-way management will be incorporated into construction and maintenance activities through the pennittfng process. 7.Since publication of the transmission line corridor screening report, further stUdies on both the corridors between the dam siteS and the access route stUdies have been conducted.The access route report,to be issued in April,'concludes the most environmentally acceptable route between the two dam sites ia on the north side of the Susitna River.In order .to utilize a common corridor,it is now planned to ~lace the transmission lines on the north side of the Susitna River; this routing is contained in the Susitna Draft Feasibility Report. Should proposed access routing change,consideration will be given to moving the transmission line route to maintain the common corridor concept. 8.We agree that public access is a complex and controversial subject. We experienced the wide range of opinions on this subject when con- ducting public meetings on the access route.Decisions on extent of public access will be made in the broader forum of the permitting process which includes concerns of the resource management agencies. 9.Due to existing land use,aesthetic and lifestyle constraints,con- sideration was given to paralleling existing rights-of-way and utilizing existing access points whenever possible.The existing Healy-Fairbanks transmission line was the focus of studies in the northern study area. Closely paralletdgg this line,the Parks Highway or the railroad right- of-way was considered but rejected due to the extent and severity of resultant impacts.These impacts were:the need to remove buildings located adjacent to these corridors;placement of conspicuous trans- mission facilities in the foreground viewshed of existing houses;and placement of transmission facilities in the foreground viewshed of the major travel corridors of the rail belt region. 10.Consideration of alternatives south and east of Willow,inclUding those aligned with existing rights-of-way,was undertaken in the corridor selection process.Due to the presence of the proposed capital site, topographic limitations,and existing land use limitation,especially in the area from Eklutna to Anchorage,it was concluded routing options to the south and west of Willow would result in fewer environmental impacts. 11.As mentioned above,the pennitting process will incorporate resource agency requirements regarding right-of-way clearing and maintenance.The techniques you mention may be stipulations to construction with which the Power Authority would comply. -Mr.John A.~~rrison U.S.Fish and Wildlife Service April 14,1982 - 3 .~ 12. f""" 13. 14. It is not the intention for the Susitna Hydroelectric Project to provide service to the Glennallen-Valdez area in the near future.If service was provided,it would be based on economics and need;current load forecasts indicate no such needs until after the year 2000. See response number 9 regard1ngthe Healy-Fairbanks line. With the exception of existing lifestyle,all the technical environ- mental criteria you suggest be added to Table 5.1 for corridor selection were utilized in the corridor screening process as discussed on Pages 6-5 through 6-9 and displayed in Tables 6.4,6.5,and 6.6., 15.Access for construction and maintenance w111 be defined following final right-of-way selection.Tire corridor selection process has resulted in much o~the proposed cor~idor being located in close proximity to existing seconaary roads,survey lines,tractor trails,or existing transmission lines,thereby reducing access needs. 16.Steep terrain was considered as a negative environmental factor as discussed on Page 6-7. 17.Clearing needs will be more fully evaluated following fijht-of-way selection. 18.The result of the corridor screening report was the selection of corridors several miles in width.A final right-of-way,400-700 feet ~wide,will be selected at a later date.Enhancement opportunities will be considered when selecting this final right-of-way. 19.We agree that longer length of a transmission line does not necessarily mean greater environmental impacts.TIhe wording on Page 6-6 reflects this,stating "A longer line will require more construction activity than a shorter line,will disturb more land area,and will have a greater inherent (underlining added)probability of encountering environmental constraints.1t 20.Construction procedures will be designed to minimize scarification. The permitting process may result in stipiuations to prevent or mitigate scarification. 21.The National Park Service and the State Hfstoric Preservation Offices will be contacted regarding cultural resources. 22.I assume your canment regarding proper timing of construction would minimize vegetation impacts refers to winter construction in wetlands. This.is recommended as a mitigation technique on Page 7-6 of the report. - Mr.John A.Morrison U.S.Fish and Wildlife Service Apri 1 14 ~1982 - 4 23.The opportunities far-increased access,\'1here desirable,and for restricted access (through use of discontinuous access roads,physical barriers~etc.)will be considered during right-of-way selection.The requirements of the resource management agencies will be included in the permitting process which will result in a decision on the extent of public access to be allowed. I appreciate your comments on our report and hope these responses are satisfactory.In summary.addttional studies and mitigation planning will be consucted in the near future;this reviewed report and the Feasibility Report mark the beginning of this process. S1ncerely~ John Lawrence Proj ect t~anager GG:ccv ...., Dear I am enclosing for your review the following reports prepared by the Alaska Department of Fish and Game for the Susitna Hydroelectric Project: 1.Final Draft Report,Adult Anadramous Fisheries Project 2.Resident and Juvenile Anadramous Fish Investigations on the Lower Susitna River 3.Aquatic Habitat Investigations. These reports are provided for your information only;they are not part of our formal Agency Coordination Program.Comments are not requested but will certainly be accepted. Sincerely, Preceding Letter Sent To: J'1r.Al Carson Division of Research &Development Department of Natural Resources 323 East Fourth Avenue Anchorage,Alaska 99501 Mr.Bradley Smlth Environmental Assessment Division National Marine Fisheries Service Federal Building &U.S.Court House 701 C Street,Box 43 Anchorage,Alaska 99513 Mr.Michael Scott District Fisheries Biologist U.S.Bureau of Land Management 4700 East 72nd Street Anchorage,Alaska 99507 Mr.Gary Stackhouse U.S.Fish &Wildlife Service 1011 East Tudor Road Anchorage.Alaska 99502 7'"Mr.Carl Yanagawa Regional Supervisor for Habitat Division Al ask a Department of Fish &Game 333 Raspberry Road Anchorage,Alaska 99502 b Ms.JUd 1 Schwarz Environmental Evaluation Branch U.S.Environmental Protection Agency Region X 1200 Sixth Avenue Seattle,Washington 98101 - '~ ALASKA POWER AUTHORITY April 15 ~1931 Mr.Gary Stackhouse .U.S.Fish &Wildlife Service 1101 E.Tudor Road Anchorage,Alaska 99501 OearGary: Attached is a copy of our report to the Legfslature as promised by me earlier this week.I am also sending n copy to Bruce Apple. Bruce tells:me he has.a copy of the Plan of Study.Since these are an endangered species.I would appreciate it if you would share his copy as you structure your shopping list of areas of concern. Sincerely, FOR THE EXECUTIVE DIRECTOR David O.Wozniak Project Engineer Attachment:As noted CONCUR: OW RAM ALASKA POWER AUTHORITY April 15 ~19a1 Ms.Judy Schwartz Environmental Evaluation Branch Hail Stop 443 Re9ion 10.EPA 1200 6th Avenue Seattle,Washington 98101 Dear Ms.Schwartz: Attached is a mid-point report on Sus1tna Hydroelectric Project.It is forwarded for your information in "response to your earlier expression of in- terest within the context of the Sus1tna Hydroelectric Project Steering Committee. I have asked Hr.Allan Carson,the:Chairman of that cmrmittee,to forward meeting minutes to you and to ensure that you are advised of scheduled meetings. Sincerely, fOR THE EXECUTIVE DIRECTOR David D.Wozniak Project Engineer Attachment:As noted cc:Allan Carson w/o attachment CONCUR: DW RAM ,~ DrVISION OF PARKS December 4,1981 Re:1I30-13 John D.La~rence Project Manager Acres American,Inc. The Liberty Bank Building,Main at Court Buffalo,New York 14202 Dear Hr.Lawrence: JAY S.H,l.MMOND.GOVERNOR 619 WAREHOUSE DR••SUITE 210· ANCHORAGE•.ALA~KA 99501 PHONE:214..4616 -- We have reviewed the 1980 repoits by the University of Alaska Museum dealing with the cultural resources of the Susitna Hydroelectric project area.7be. report documents the survey activities cooducted during 1980 which adequately accomplish the tasks outlined in the proposed work plan.The sampling plan designed on the basis'of geomorphic features and known use areas seems to have surpassed oUF expectations of site incidence in the areCf •.The report shows th?t the first.level invento~was very competently conducted and recorded. The second year activities as outlined in the procedures manual was accom- plished in the 1981 field season according to information gained through verbal communication with the principle archaeological investigators.We understand that the field research strategy was changed slightly from that expected due to information gained during 1980.These changes appear to have more directly addressed problems which surfaced during the course of analysis' of the 1980 data.A final review of the 1981 results and reports will have to a\Ja it receipt of tha t document. ~e feel tbat the steps taken tbus far in the cultural resource management of the project have been excellent and ooe of the few instances of adequate lead time.~e \Jould like to make the observation that the ~ork thus far is only preliminary to the ~ork yet needed for the Susitoa Hydroelectric project. Reconnaissance and testing of yet to be examined areas should continue.The clearances of specific areas of disturbance provided as additional survey by the Huseum should indicate the continued need for clearances of ancillary projects ~hich could affect cultural resources.Also,a formal mitigation" plan for those sites to be affected by the project must be formulated.Once definite decisions on the route of access to the project area from existing road systems are made,those access routes and material sites must he examined for conflicts and Deeds for mitization.Issuance of a permit by the Federal Energy Regulatory Co~issioQ should and probably will ioclude provisions ~pecirying under federal law the need for such protection. John D.La~reDce December 4,1981 Page 2 - If you have any questions regarding our comments contained here,please call us.We look forward to receiving the report on 1981 field work. Sincerely, Chip Denne1ein Director By: A •Shaw ~ Preservation Officer cc:D~E.James Dixon Curator of Archaeology University-of Alaska Museum University of Alaska Fairbanks,Alaska 99701 Eric Yould. Executive Director Alaska Power Authority 333 W.4th Avenue Anchorage,Alaska 99501. "I DR:clk - - Colonel Lee R.Nunn Department of the Army Alaska District,Corps of Engineers P.O.Box 7002 Anchorage,AK 99510 February 19,1982 P5700.11.92 T1519 Dear Colonel Nunn:Susitna Hydroelectric Project P1 ant·Eco 1 09y"Repott . . . . . . Thank you for your letter of February 1 regarding your revi ew of the following reports:Environmental Surrmary Annual Report -.1980,Development Selection Report,and Transmission Line Corridor Screening Close Out Report. As a result of your comment concerning wetlands,I am enclosing for your ,-..information a copy of the 1980 Plant Ecology Report which more specifically addresses the wetlands issue.Also enclosed is a copy of the vegetation and wetlands maps which are referred to in thei~report. +1,1.:;> Thank you again for your letter. ~erelY' John Lawrence Project Manager MG:ccv Enclosures cc:E.Yould -APA ACRES AMERICAN INCORPORATED IN REPLY REFER TO: WAES L c...L.R EC-b ·s J Ie,/s;!Pfl'65·· C!..e.:Efl1c~.=~.ej.rf3-a, JOf-\",)~Av'bE.tJ United States Department of the Interior J.IM ~L lJ M 1-\e.R. FISH AND WILDLIFE SERVICE STEv E FAiVl...Y 101 J E.TUDOR RD. ANCHORAGE,ALASKA 99503 (907)276-3800 1 7 AUG J982 Eric P.Yould Executive Director Alaska Power Authority 334 W.5th Avenue,2nd Floor Anchorage.Alaska 99501 Dear Mr.Yould: The Alaska Power Authority (APA).by letter dated 29 July 1982.requested comments from the Fish and Wildlife Service (FWS)regarding construction access alternatives for the proposed Susitna Hydroelectric Project.We hope. with this letter.to convey our immediate concerns regarding this subject to facilitate your decision-making.This letter should not be construed as providing in toto our concerns related to project access.We fully intend to provide substantive comments on this.and related issues.upon receipt of the draft Federal Energy Regulatory Commission (FERC)license application Exhibit E.(Federal Register Vol.46.No.219.November 13,1981). The FWS has expressed.through our participation on the Susitna Hydroelectric Steering Committee (SHSC)(letters dated 26 March 1981 and 5 November 1982), concerns as to the direction and emphasis which this issue has taken. It is apparent that the APA has been lead to the present :3"access alternatives by the conclusion that power must be the forthcoming in 1993.Presently.the 1993 deadline is constraining the overall decision-making process and the orderly progress of various studies on project feasibility and environmental impacts and alternatives.The External Review Panel.in their Report, presented to the Board of Directors,Alaska Power Authority on 15 April 1982. did not acknowledge the 1993 mandate,prefering to state that: "The arrival of any opportune time to proceed with construction will depend on critical issues of finance and marketing of power which cannot now be accurately forecast.Our recommendation is that tender documents with all supporting geotechnical investigations and design studies be developed.We estimate that a total period of three to four years will be required for this phase of work.The project will then be ready to be implemented whenever the financial climate for contracting becomes favorable.The advantages of proceeding in this manner are: (I)The economic benefits of being ready for financing; (2)the momentum of the ongoing study and an informed staff;and (3)the ability to avoid a crash design program. ,.... The disadvantage is the small risk of loss of the design costs in the event that,for some reason,the project is never built. This Panel is of the opinion that the economic climate will eventually indicate that it is advisable to proceed with the construction of the Susitna project and at that time it will be in the best interests of the State of Alaska to develop this important natural resource." Given the above the FWS continues to endorse the views expressed in the Steering Committee letter dated 5 November: "The SHSCagrees with the Terrestrial Environmental Specialists,Inc. position that access via the Al~ska Railroad to Gold Creek is environmentally preferable.Railroad access to at least Devil Canyon would alleviate the need for a staging area at Gold Creek ana the consequent human activity,land use,fuel spills,and other impacts on the Gold Creek area.We recognize that a staging area at Devil Canyon would be required in any case.The use of this area as the terminus of a railroad appears to make a great deal of sense.Additionally,we feel that the south side route from Gold Creek to Devil Canyon is preferable since a trail already exists there.From Devil Cariyon to Watana,we prefer a route on the north side of the Susitna River •If feasible we generally prefer a rail mode of access to and within the project site. The SHSC identified three (3)environmentally sensitive areas that should be avoided.Those are: 1.The routes from the Denali Highway. 2.The route crossing the Indian River and through wetlands to the Parks Highway. 3.The route on the south side of the Susitna River from Devil Canyon to the proposed Watana dam site • • • •Use of rail as the access mode increases the potential for management and control of socioeconomic and environmental impacts. Maximized rail use provides for the following advantages over road access: 1.Maintains a maximum range of future decision options. 2.Provides for control of worker impacts on local communities and wildlife. !,.... - 3.Decreases the potential of hazardous material spills due to adverse weather conditions and multiple handling. 4.Disturbance to wildlife adjacent to the route can be more easily controlled. 5.Direct access right-of-way related habitat losses can be significantly limited." We"b~lieve that rail,in conjunction "lith air access,would provide dependable se;vicc'and that a redundant system of rail and road is not a necessary pro- ject feature and,as stated above,is environmentally undesirable. An assessment of corridor route alternatives must weigh the potential impacts of borrow sites and access to these sites,and transmission line(s)routing and maintenance.Access corridors which serve a dual,or triple,purpose in regard to those other project access needs would be highly desirable from all decision-making criteria. Public access to the damsites and through the Upper Susitna Valley is a complex and a controversial subject.and we believe this issue should be given thorough evaluation in the selection of'access routes,mode of access.trans- mission line routing,and method of maintenance access for the transmission lines.How construction and maintenance related access is obtained to a great extent determines the project-related wildlife and socioeconomic impacts. The following comments are provided in light of our concerns and are not an endorsement of these routing alternatives. Alterna>J.ve 17 Terrestrial Environmental Specialists,Inc.expressed the op1n10n that the Denali Highway alternatives should not be considered.The view that the risk of substantial negative impact to the Nelchina caribou herd from a Denali Highway route is high has also been expressed by Karl Schneider,Research Coordinator,Susitna Hydroelectric Big Game Studies,Alaska Department of Fish and Game.We concur.There may be a difference of opinion amongst partici- pants in the Susitna Hydroelectric Project Study as to the extent of the risk.However,we must conclude that the Nelchina caribou herd could be substantially negatively impacted by an access route connecting the Denali Highway to the Watana camp;and that these risks are avoidable. In addition to potential risk to the caribou,the Denali route cuts across valuable moose,brown bear,and black bear habitat between the Watana camp and Deadman Lake.Although no major river crossings would be involved,numerous small river and tributary crossings would need to occur along this route and could pose .extensive problems to numerous virgin grayling fisheries. Alternative 16 A southern routing between the dam sites could intersect movements of large numbers of brown bears to and from Prairie Creek.The upper Prairie Creek, Stephan Lake,and the Fog Lakes regions support large year-round moose concen- trations.Impacts to furbearers and waterfowl also appear to be less avoidable in a southern routing between Watana and Devil Canyon in comparison to a northern access route. ..... Alternative 13 \O/e favor Dn access route to the north of til..,Susitn,j River bcu..een thl::t\ol(l darn sites.However.we cannot endorse the proposed routing.Given the stated rationale that the siting of the Devil Canyon dam was partially an attempt to avoid adversely impacting the important salmonid fishery of Portage Creek we are highly concerned with any plans to place a road in close proximity to the creek for approximately 1 mile.This places the fishery in a highly vulnerable position in respect to erosion and hazardous spills. In summary.the FWS recommends: 1.That justification for the power-on-line in 1993 planning objective be clarified. 2.Rail access into the project site.to the exclusion of a road connection. with routing north of the Susitna River between the two dam sites. 3.That alter-natives for borrow sites and their access.and transmission line(s)routing be provided so that they can be considered in conjunction with construction access routing. 4.That public access to the upper Susitna.basin should be evaluated within the context of the project's need to minimize.to thee~tent possible, adverse impacts to fish and wildlife,and their habitats. Thank you for the opportunity to comment. Sincerely. A.sista.H /Regional Director•.. cc:FWS-ROES,WAES Quentin Edson/FERC APA.NMFS.EPA,NPS,USGS.ADEC.AEIDC ADF&G.Hab.Div ••Su Hydro/Aquatic Studies Robin SenerlLGL APA Board 1'Iemhers ----------- IN REFLY REnR TO: L7621(ARO-PCR} Uni ted Sta tes .Dcpartnlen t of the rn terior NATIONAL PARK SERVJCE Alaska Regional Office 540 West Fifth Avenue Anchorage,Alaska 99501 OCT 22 1982 Dr.E.James Dixon,Jr. Curator of Archeology University of Alaska Museum University of Alaska Fairbanks,Alaska 99701 Dear Dr.Oi xon :. Our staff has examined the Susitna Hydroelectric Project cultural resources final report,tin particular the identification and testing program elements of the research'i cre$ii9!1l",and find these and their field application to be very adequate methods ~procedures for the discovery and evaluation of archeologi- cal and lJistorical!resources in the project area.Consultation between our staff a,rcnenlo!li;s;1ts:and project personnel from the Universi ty of Al aska Museum and ACFes,JAlneric.iHlt~"as you well know,have occurred several times since the projectls inception,and we have thus been kept abreast of most developments relating'to,C\!I)l:1n:l:ral resources management matters.We hope that the level of identiffca'ttio:A',t.esting,and evaluation conducted to date continues as the project proceeds,to assure the highest levels of resource protection and compHar.tee with Federal and State historic preservation law. We look ~0r.ward to evaiuating your mitigation plan for cultural resources occurring in the project area. Sincerely, Regional Director Al aska Region cc: Floyd Sharrock.Alaska Regional Office - IN REPLY REna.TO: United States Department of the Interi9r NATIONAL PARK SERVICE Alaska Regional Office 540 West Fifth Avenue Anchorage,Alaska 99501 NOV -21982 L7621 (ARO-PCR) OCT 221982 Dr.E.James Dixon,Jr. Curator of Archeology University of Alaska Museum University of Alaska Fairbanks,Alaska 99701 Dear Dr.Dixon: It AI KftV '\'POWIiR AlmfoRny SUSnNA FILE P57~-/(.1/ SEQUENCE NO.c II q 1 J1 I" Z ~cd i0!i=0 ....u u.II)~:.r ~5 -r---"JOG-f--- VTS 1-?PWH iHH~-ISJl -.-:i"PB,''''-IWD I -- !MS -- I ;RC -v..._--- c-..I"" DC~v r -- APA ~t t/BUff. Rti.~ ",.~," cc: Floyd Sharrock,Alaska Regional Office Our staff has examlned the Susitna Hydroelectric Project cultural resources final report,in particular the identification and testing program elements of the research design,and find these and their field application to be very .adequate methods and procedures for the discovery and evaluation of archeologi- cal and historical resources in the project area.Consultation between our staff archeologists and project personnel from the tlniversity of Alaska Museum and Acres American,as you well know,have occurred several times since "the projectls inception,and we have thus been kept abreast of most developments relating to cultural resources management matters.We hope that the level of identification,testing,and evaluation conducted to date continues as th project proceeds,to assur~the highest levels of resource protection·and compliance with Federal and State historic preservation law. We look forward to evaluating your mitigation plan for cultural resources occurring in the project are~. Sincerely, Regional Director .Al aska Region.- .- DATE:April 6~1981 NOTES OF MEETING PROJECT·NUMBER:AAI 218 LOCATION:DNR~Division of Minerals and Energy Management;703 W.Northern Lights B1vd.~Anchorage ATTENDEES:Glenn Harrison~Director;Division of Minerals and Energy Management.J.O.Barnes~R.J.Krogseng~TES SUMMARY OF DISCUSSION: Mr.Barnes gave a short presentation summarizing the history of the Susitna Project and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority. Mr.Harrison responded that his divisions main interests involved coal~oil and gas 1Ifid that he foresaw few problems that ~he Susitna project would cause in his areas of interest. Mr.Harrison felt that the project Ilsoun ds good"and was well thought out. Mr.Harrison also commented that it would begood~as far as his division was concerned.,to have some roads built into the Susitna area. Mr.Harrison stated that he appreciated the meeting and that he would like to be.kept informed on a periodic basis. Prepared - NOTES OF MEETING DATE:April 6,1981 PROJECT NUMBER:AAI 218 LOCATION:Alaska Department of Transportation,Aviation Building,Anchorage ATTENDEES:Jay Bergstrand,DOT,Area Planner;J.O.Barnes and R.J.Krogseng,TES . SUl·tMARY OF DISCUSSION:' Jeff Barnes outlined the history of the Susitna Project and Acres and TES's role in the present studies.Mr.Bergstrand was familar with the project and had been present at some of the Susitna project meetings. Mr.Bergstrand requested a copy of the Environmental Annual Reports,and he was referred to Nancy Bl unck',s offi ce at APA. Mr.Bergstrand asked about transmission line high voltage effects~fish ,".passage problems around the dams;what was planned for disposing of the timber in the impoundment areas,and was burning being considered as a mitigation measure for moose? Mr.Bergstrand was particularly interested in the planning process for Access Roads,Transmission Line routes and transportation corridors.He showed us proposed routes for new roads in the Lower Susitna Basin and we discussed where they would cross the proposed transmission lines. Mr~Bergstrand requested more infonmation regarding the impact and amount of flying activity during the study and construction periods the Susitna Project would have on the Talkeetna Airport.This information would be used to ascertain if the state would have to provide more services at the Talkeetna airport.(A letter.requesting this information was sent to Mr.Brownfield of Acres on April 16,1981). Prepared by ~a L .J.K gsengpES Page 2 Mr.Baya inquired about the status of legislatiy.e funding to cover the rest of Phase I studies and the tran~it;on period. Mr.Baya wanted to know if any incremental instream flow work was being done on the Susitna River by the state. Mr.Baya feels that more attention needs to be paid to instream flow impacts, the effects can be far-reaching.He pointed out that the move of the state capitol,urban growth of Anchorage and the Mat-Su,.the proposed causeway to Point MacKenzie,all could cause serious impacts and need to be considered in a regional planning effort.He also pointed out the need to recognize the secondary impacts that a large supply of hydroelectric power would cause. Mr.Baya pointed out that the Fish and Wildlife Service will be asked by the Secretary (of Interior)to respond with comments during the FERC review process. The F&WS also has the requirement to coordinate fish and wildlife view points from the different agencies.Mr.Baya feels that the Susitna project has moved forward too far without funding for Fish and Wildlife Service participation. He would like to have a man assigned full time to the Susitna project to monitor the studies and keep him up to date because in the near future he will have to ask himself "can I si gn off on that?·1 Mr.Baya feels that the APA needs to find a way to get the F&WS actively involved. They need money to finance a staff position (approximately $50 -60,000 a man year).Normally when the Corps of Engineers have a project they would give the F&WS money eve~six months through an allocation transfer. Mr.Baya commented that recent cutbacks have caused problems and will probably result in a reduction in staff.In spite of these problems Mr.Baya said "we want to help plan a sound program .••..we donlt want to be obstructionists.II II •••but without·funding for a full time position it will be virtually impossible to completly review the study in a short period of time. Mr.Baya commented that in projects in the lower 48 states they have found that often they had not looked far enough down the road to be aware of all of the impacts~For instance,along the Mississippi River the State of Mississippi is 'losing 16 miles of Delta every year,because river channelization is dumping sediments in deep water instead of spreading them over the delta areas. r'--- NOTES OF MEETING DATE:April 6,1981 PROJECT NUMBER:AAI 218.- LOCATION:DNR Office,323 East 4th Ave.,Anchorage ATTENDEES:Mr.Ted Smith,Director,State Division of Forrest,Land &Water Management,ADNR.Mr.J.D.Barnes,Mr.R.J.Krogseng,TES SUMMARY OF DISCUSSION: Jeff Barnes outlined the history of the Susitna Project and TES's role in the studies. Mr.Smith had recently talked to Brent Petrie (now of APA)about the Susitna project and he appreciated the briefing and the concerns shown for his departments interests. Mr.Smith expects to get relief from the Legislative mandates which he feels are causing many of the problems in the state land disposal program. Mr.Smith feels that the access roads for the Susitna Project will help to.....open up and provide access for more state disposal lands. Mr.Smith strongly feels that the Alaska Power Authority should file applications for water rights as soon as possible to both reserve the water rights and to help DNR plan.(Alaska has recently adopted a water righ~s law similar to that of Montana and other Western states).He also would like to see applications.. from APA designating approximate routes for access roads and transmission lines so they can be included in DNR's planning at the earliest possible date. Prepa red by --:(J::F-'~::---::-7~"f--'_.~l""J==:::----Y£ilihseng {'RES - NOTES OF MEETING DATE:April 7,1981 PROJECT NUMBER:AAI 218 LOCATION:State Parks Headquarters,619 Warehouse Avenue,Anchorage ATTENDEES:"Jack Wiles~Robert Shaw,Doug Reger,Alaska State Parks;Kevin Young,Acres;Jeff Barnes,Lew Cutler,R.J.Krogseng,TES. SUf1MARY OF DISCUSSION: Mr.Barnes gave a short presentation covering the histo~of the Susitna Project and the role played by Acres,TES,and other subcontractors in the present study for the Alaska Power Authority. Mr.Shaw and Mr.Reger requested a copy of the Plan of Study and the Archaeology Procedures Manual.(Mr.Cutler will go over the Annual Report with Mr.Reger on the 8tIr of Apri 1)• Mr.Wiles was concerned that if the State Parks Department would be the manager around the reservoir area,how_big was the area going to be,or would it just be the 200 foot buffer strip. -Mr.Reger wanted to know what was~the FERC application.He also wanted to know if the FERC people would consult with-his staff office.He also commented that they hadn't been involved up till now. Mr.Shaw wanted to know what the overall construction schedule would be. Mr.Wiles inquired about the status of the-access road and what the present .-_.:._..-_. plans were. It was also established that artifacts that came from native owned ground are usually placed in the University of Alaska Museum to be held in trust for the natives. All attendees agreed that the Susitna Project "sounds good"and they were satisfied with the planning that had gone into the.studies. Prepared by ~'#R.J.Kr seng ES NOTES OF MEETING DATE:April 7,1981 PROJECT NUMBER:AAI 218 LOCATION:USF&WS,Tudor Road,Anchorage ATTENDEES:Keith Baya,Assistant Area Director F&WS;Kevin Young,Acres; J.O.Barnes and R.J.Krogseng,TES. SU~mRY OF DISCUSSION: Mr.Bayawas recently assigned to Alaska so Mr.Barnes's presentation covered the histo~of the Susitna Project,the role of Acres and TES in perfonming the studies for the Alaska Power Authority,and an outline of the studies in progress to ijelp bring Mr.Baya ~p-to~date on the projeet~ Mr.Baya appreciated the briefing on the project and conmented that he would like to see the Susitna River studied all the way down to the estura~y to be sure there were no unforeseen problems.He acknowledges that.effect~on the lower river may be difficult to measure"He also felt that another question that will arise is "why isn't it like other hydro projects?" Mr.Baya felt that the NEPA decision making process should be followed. Mr.Baya believes that the Sus'itna study is going to be one of the major studies for the next few years.He feels that the Fish and Wildlife Service needs to-be involved in these studies and that his people have some expertise,but they need to be on the ground to be able to see and -supervise the studies~-'If-~~ they are not included Mr.Bayabelieves the "----FERC coordination may take longer than felt politically wise or timely." Mr.Baya expressed an interest in what studies were pl.anned for the coming year. If there is an early June tour for Starker Leopold,Mr.Keith Baya would.like to be included. Mr.Baya wanted to know·if Habitat Evaluation Procedures (HEP)were being used in the studies.He felt that it may be necessary to do a HEP analysis 'later on. Mr.Baya inquired about Dr.B.Kessel's Avian and Small Mammal Studies and what was scheduled for the summer field studies. Page 3 Mr.Baya also commented on the EIS that will be written on the Beluga Coal fields in the next few months,and how they plan to build a model to help figure out what (data)is drivi.ng the system ••They also will be looking at the question of whether it would be better to build a port at Tyonek or haul the coal by railroad to Seward. Prepared·by ~.J.K gsen TES - NOTES OF MEETING DATE:April 7,1981 PROJECT NUMBER:AAI 218 LOCATION:Department of Community &Regional Affairs,225 Cordova, .Building B,Anchorage . ATTENDEES:Ed Busch,Senior Planner;Lamar Cotten,Associate Planner; .Kevin Young,Acres;J~O.Barnes and R.J.Krogseng,TES. SUMMARY OF DISCUSSION: Mr.Barnes gave an overview of the history of the Susitna project,Acres and TES's involvement in the present studies and our reaSOn for talking to people from their department. Mr.Busch was aware of the steering committee through A1 Carson.f>1r.Busch's department provides planning"assistance to conmunities upon request.The Department"also has a management program.One of their programs provides coastal zone management for the Matanuska-Susitna Borough.This could extend up the Susitna River. Mr.Busch1s office has had sporadic involvement with the Susitna project.- He was on the review committee on contractor selection and also attended some of the workshops. Mr.Busch voiced some concerns that his office has about planning for the Susitna project.He feels there will be a number of impacts on local governments,and he wanted to know if their concerns had been considered? Mr.Busch believes that the-Matanuska-Susitna Borough will bear the brunt of the impacts (positive and negative)caused by the Susitna project.A major problem will be providing increased services. Mr.Busch wanted to know if the access roads would be kept open after the project was f;ni~hed and who will maintain them.He also wanted to know, if the railroad is built,has anyone considered the impact to Talkeetna caused by people driving to Talkeetna,parking and taking the train? Mr.Busch"recolmlended that TES do comnun i ty profil es on the towns and vi 11 ages that would receive most of the impact.As ~minimum he suggested community profiles on Talkeetna,Cantwell j,Paxson and Gold Creek •.AcolllTlunity p~o·file· is a collection of information with photos and a map of the community. (examples were provided).The profiles have been costing $10-11,000 to produce with the majority of the expenses going for per diem expenses and cartography. PAGE 2 (Northwest Gas Pipeline Company produced some of the examples). Mr.Busch pointed out that if a village is incorporated into a second class city (such as Talkeetna)they are able to have more input in planning and governing themselves.For the smaller villages the State Legislature is the governing body,with the actual planning done by Mr.Buschls department. Wildlife planning is done by the ADF&G,and the Matanuska-Susitna Borough provides the schools.Mr.Busch does not speak for the Borough unless he has been requested to do so. Mr.Busch feels the number of construction workers has been under-estimated, as an example,the Alyeska pipeline was under-estimated. Mr.Busch recommended that a permanent construction camp be built for the projec~The temporary camps built for the pipeline are still being used and it would have been cheaper in the long run to build permanent camps. Mr.Busch commented that people from Frank Orth and Associates have talked to personnel in"his office. Mr.Busch also pointed out that the only way his office gets involved is when they have been asked to by the community. Prepared by tJ.Iit:'-re 71 J.Kr eng,TES "I .... - NOTES OF·MEET ING. DATE:April 8,1981 PROJECT NUMBER:AAI 218 LOCATION:Oepartment of Pub1 ic Safety,Division of Fish and Wild1 ife Protection,5700 E.Tudor-Road,Anchorage ' ATTENDEES:Colonel Robert J.Stickles,Director;Lt.Col.Tetzlaff,Capt • .Wayne Fleek,Lt.Rod Mills,Department of Public Safety;Kevin Young,Acres;J.O.Barnes and R.J.Krogseng,TES. SUMMARY OF DISCUSSION: Mr.Barnes presented an overview of the history of the Susitna project and the part played by Acres and TES in the present studies being conducted for the Alaska ,Power Au~ority. Col.Stickles,requested that his department receive copies of the annual reports for Fish,Big Game and Access Roads. Col.Stickles asked what effect the dams would have on the {low of theSusitna River below Talkeetna.·He also wanted to know what water temperature changes may occur.He was very interested in the possible effects the'project would have on moose and caribou.Co1.Stickles also wanted to know how many miles of access roads were planned. Col.Stickles wanted to know what ice effects were expected in the impound- ment area and also the effects expected in the downstream reaches of the river. He also wanted to know what the construction time table was and when it would start.He needed,this infonmation to help plan for the placement of officers. He will probably assign an officer to Chulitna when·construction starts. Capt.Fleek asked about the amount of helicopter useageduring the studies. He also wanted to know where the transmission ,line routes would be and if there would be access roads along them. Capt.Fleek wanted to know how many people would .be living Dear the dams for· ",... maintenance and operation of them. Capt.Fleek wanted to know if the impoundment areas were going to be logged. He also was concerned that i~e shelving might cause caribou crossing problems. Capt.neekconmented on t~e large ntnnber of bear in .the area and wanted to know if we had had any bear problemS.He also requested that Fish and Wildlife Protection Division be sent the results of the Mitigation Committee. Their division would ·like to be in on mitigation planning... ,.... PAGE 2 All agreed that Protection Divisionis greatest concern would be the access provided'to the area.They wanted to know if a landing strip was going to be built.They would also be interested in getting.permission to store extra gas for their helicopter at Camp Watana later on. It.Mills said that they could tell us the number of guides using the area. and he agreed to send Krogseng a list of the guides and their best guess on the number of hunters using the area. Reported by DATE:April 8.1981 NOTES OF MEETING PROJECT NUMBER:AAI 218 ,.... I LOCATION:Department of Energy.Federq1 Building.A~chorage ATTENDEES:FredChiei.Deputy Regional Representative;Kevin Young.Acres; J.O.Barnes and R.J.Krogseng.TES. SUMMARY OF DISCUSSION: Mr.Barnes made his presentation covering the history of the Susftna project and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority. Mr.Chiei appreciated being kept informed on the status of the project. Mr.Chiei commented that his office is an off-shoot of the Secretary's office and that he deals primarily with energy'policy'. Mr.Chiei noted that the FERC people operate out of his office when they are in town •.while the FERC engineers operate out of San Francisco.He also commented on the need for energy planning. Mr.Chiei said that his office tries to stay out of the states territory in energy matters.although a lot of things have not surfaced yet.He prefers it to be more of a state project and is happy to see state fundi ng for it. Mr.Chiei commented that hydroelectric_projects_1tke the_Susitna PToj_~C~. •4..••-;_.• release energy like coal.oil .and.gas tryat can be shipped elsewhere in the U.S.which helps to di stribute the country's energy more evenly. Mr.Chiei said that he doesn't see any problems at this point and periodic reports (like this meeting)would be sufficient.He would also be interested in seeing the development scenario when it is developed. Mr.Chiei would like to receive information from Acres on the Tidal Power Study. NOTES OF MEETING DATE:April 8,1981 PROJECT NUMBER:AAI 218 LOCATION:National Park Service,540 West 5th Avenue,Anchorage ATTENDEES:Howard R.Wagner,Associate Director,Carl Stoddard,Ter~ Carlstrom,Ross Cavenaugh,National Park Service;Kevin Young, Acres;J.D.Barnes,R.J.Krogseng,TES. SUMMARY OF DISCUSSION: Mr.Barnes outlined the history of the Susitna project and the role Acres and TES have in the present studies being conducted for the Alaska Power Authority. Mr.Cavenaugh asked how the Fish and Wildlife studies fit into the overall planning process.He also asked what was being done about cultural resources. Mr.Cavenaugh,also wanted to know what effect the project would have on the proposed Denali Scenic highway. Mr.Wagner said that he would be very interested in the transmission line route,especially where it is near the park (Denali).If the route passes through park boundaries,the right-of-way approval may ·need congressional level approval.They want to keep the transmission line out of 1:he park. .. Mr.Carlstrom wanted to know what range of considerations or options were available.He cOlJlTlentedthat access could be a direct "problem.The Denali· National Park is only on the west side of the Parks highway,but the trans· mission line would have a direct impact on the land across the road.He also wanted to be sure that someone was looking at indirect impacts caused by the proj ect. Mr.Wagner also commented that USGS would soon have 1:250,000 scale maps with the"new park boundries marked on them. Reported by:.-L~l:t!.~~::::l'~~~~'~J~--r~_=:--__-;;;"'-~Krogpiig.TES NOTES OF MEETING ,~ DATE:April as 1981 PROJECT NUMBER:AAI 218 .... LOCATION:u.s.Army ~orps of Engineers s Elmendorf AFB s Anchorage ATTENDEES:Lt.Col.Perkins s Deputy District Engineer;Kevin Young.Acres; J.D.Barnes and R.J.Krogseng s TES. SU~~RY OF DISCUSSION: Mr.Barnes briefly covered the role of Acres and TES in the present studies of the Susitna project being performed for the Alaska Power Authority • Lt.Col.Perkins stated that the Corps has no funding for any work on the Susitna project.- Lt.Col.Perkins strongly feels that the state should be asking the Corps; What permits will ·~e required?The state should also inquire about getting one blanket permit for the project. Lt.Col.Perkins wanted to know if we knew what permits would be needed s in particular any section 404 classification of wetlands would be filled in. -He recommended t~at the head of his environmental group be contacted. Lt •.Col.Perkins also noted that the access roads will require permits to cross wetlands;also any dredging or filling that is required.Permits will also be required for constructing the transmission lines,especially if access roads are bull t. Lt.Col.Perkins pointed out that it takes a minimum of 200-220 days to process a permit.and if there are any objections they may have to be resolved in Washington s which will require even more time~ \DATE:April 9,1981 NOTES OF MEETING PROJECT NUMBER:AAI 218 LOCATION:NOAA National Marine Fisheries Service,Federal Building, Anchorage AJTENDEES:Ronald Morris,Supervisor,Anchorage Fie19 Office,Brad Smith, NOAA Fisheries Biologist;J.D.Barnes and R.J.Krogseng,TES. SU~~RY OF DISCUSSION: Mr.Barnes gave a presentation covering the history of the Susitna project and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority. Mr.Morris and Mr.Smith are both members of the Susitna Hydro Steering Committee and they will coordinate their work with the state fisheries people. Mr.Smith will be in contact with Dr.Dana Schmidt of TES concerning the fisheries studies. Mr.Morris asked about dam design features and said that he will be in contact with NOAA engineers in the Oregon office. Mr.Morris said that they appreciated the contact. ..... NOTES OF MEETING DATE:April 9.1981 PROJECT NUMBER:AAI 218 LOCATION:Alaska Department of Environmental Conservation,437 E.Street. Anchorage ATIENDEES:Bob Marti n.Regi ona1 Environmental Supervi sort Steve Zrake.DEC; Kevin Young.Acres;J.O.Barnes and R.J.Krogseng,TES SUMMARY OF DISCUSSION Mr.Barnes outlined the history of the SusitnaProject and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority. ..... - Mr.Martin asked what impacts or changes were expected on water quality or air quality.He also wanted to know if the studies were long enough to establish a proper baseline ~eriod. Under socioeconomic,Mr.Martin wanted'to know if we had studied power genera- tion needs.He was referred to the ISER study. Mr.Martin wanted to'know if the studies would continue after the FERC applica- tion has been made.Mr.Martin also wanted to know "why the FERC application date was set so soon".As an exampl e.Mr.Marti n wanted to know why the decision on the access road had to be made so soon;he wasn't even "comfor- table"with how the three routes had been selected.He stated that his department would like to keep access down because it would be easier to manage. The Department of Environmental Conservation's interests in the Susitna area are administered out of Mr.Martins Anchorage office.His major point of contact is the Susitna Hydroelectric Project Steering Conmittee. DEC's direct regulatory responsibility is waste water.drinking water,and solid waste disposal.DEC also has an interest in instream activities. Mr.Martin recom'TIended applying for a variance to build the construction. camps to provi de for drinki ng water and waste water and sol id waste disposal. Mr.Martin feels that the major impacts of construction activities are going to be the access roads and the locations of construction camps~ Mr.Martin said that it may be easier to have just one transportation corridor. ,~As aD example,in transportation and handling of fuel~accidents are bound to happen.like a truck may roll off the road.He feels that it is important to avoid as many critical habitat areas as possible. Mr.Martin was also interested in the water quality studies.He feels it is very important to get a complete water quality series before road construc- tion starts.He wants to be able to measure construction effects.such as the run off into streams.from road bUilding. Mr.Martin is also impacted by roads. sufficient. interested in the .smaller feeder streams that would be He feels that 2-3 years .of data from studies would be Mr.Martin expressed a concern about communities along the river disposing of wastes in the Susitna River. Mr.Martin was especially concerned about the fuel transportation and storage system and the amount of fuel that would be used in a large project like Susitna.He feels it is necessary to plan to avoid or minimize accidents or spil~ Mr.Martin commented on the need to maintain ecological integrity through land use and public use planning,and to have a voice in other areas that he can't regulate.He wants to see rational land use development.something that doesn't interfere with'habitat. Mr.Martin also wants to see more attention paid to using energy alternatives such as Retherford's recommendation to use electricity to run pipeline pumps instead of using oil or gas. Mr.Martin strongly recommended building a centralized construction camp. He also recommended building where the permanent facilities will be located. Mr.Zrake wanted to know if under sociocultural impacts we were looking at.. individual desires too?He also wanted to know if this would cover the trans- mission line too. Mr.Martin stated that DEC does ,not have any studies.in progress that affect Susitna.They are working on a wetlands study with specific Alaska guidelines. Prepared by----'A"="~;;.....".........,,,,,..~F-~_~-~?''--- R.J.fJ09S""V NOTES OF MEETING DATE:April 9,1981 PROJECT NUMBER:AAI-218 LOCATION:U.S.Fish and Wildlife Service,Tudor Road,Anchorage,Alaska ATTENDEES:Mel Munson,Chief Ecologi~al Services;Gary Stackhouse,F&WS; Kevin Young,ACRES;J.O.Barnes and R.J.Krogseng,TES. SUMMARY OF DISCUSSION: Mr.Barnes outlined the history.of the Susitna Project and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority. Mr.Munson asked what ADF&G's role was in the studies.He also wanted to know'what the time frame was for all of the studies ~nd when the EIS came ,. into the picture.Mr.Barnes.outlined the FERC process and where the dif- ferentparts fit in. Mr.Munson wanted to know if we had a preliminary permit for the project.He felt that it was important that the state file soon. In 1952 Mr.Munson looked at 20 different proposed dams for River,Basin Studies. _Devil Canyon and Watana Dams were part of that study.At that time he did not find any salmon in ·the upper Susitna River. Mr.Munson wanted to know if ADF&G was looking at winter moose range in the study area.From personal experience in the area,he felt that the south facing slopes on the north side of the canyon from half way between Devil Can- yon to Watana were important to the moose population during the winter. Mr.Munson has watched caribou swim the river in many different places in the Watana area,they appear to get out any place they can get up the canyon wall. Mr.Munson commented that during peak numbers of caribou he has seen 6-8000 caribou on Mt.Watana alone.Also during peak.numbers be has watched them crossing theSusitna River where many trying to swim the river would be carried do\'m-stream and drown.He has seen hundreds of dead caribou washed up on shore. Mr.Munson wanted to know what was planned to mitigate for losses of moose habi- tat.He also commented that he opposed the Denali Dam because it would flood a.. highly productivity area. Mr.Munson also wanted to know if we were looking at the area above the Tyone Ri ver. Mr.Young outlined the various dam schemes that had the Devil Canyon -Watana scheme had been selected. that it was a good choice. been considered and why Mr.Munson commented Mr.Munson said that one of the things he was interested in was what we were going to do to mitigate for lost moose habitat.He felt that there was a need for habitat development on upper Watana Creek.-Mr.Munson also suggested burning,cutting or even sprigging willows as things to consider on Tsusena Creek. Mr.Munson was interested in the mitigation task force and its review group, although he commented that there is not much you can do for caribou. Mr.Stackhouse asked'what the status of the mitigation policy was.He hoped the group would be able to produce a policy for APA.Mr.Stackhouse also wanted to know what the basis for mitigation would be,was it going to be based on an acre.for an acre or an animal for an animal? Mr Stackhouse also asked about the vegetation analysis that was being per- fonmedihe was concerned that the studies be of a hlgh enough quality to be able to use HE?(Habitat Evaluation Procedures)on the vegetation studies at a later date. Mr.Stackhouse wanted to know if any hydraulic changes were expected in the river or if any lclng problems were anticipated.He was also concerned about the possibility of "any vegetation changes. Mr.Stackhouse felt there was a possibility of some problems "below Devil Can- yon and he wanted to know'if a re-reg dam was going to be put in.Mr.Stackhouse wanted to know what the planned construction periods for the dams were going to be,and if the Devil Canyon Coffer Dam would be big enough to serve as a '"dai ly re-reg dam." Mr.Munson asked about the expected water quality for the Susitna River between Devil Canyon and Talkeetna.He commented that it probably would have similar conditions to that found in Tazlina Lake.Mr.Munson wated to know if any ,.,.. F"'" I enhancement of the fisheries was expected,like in Kenai or Skilak Lake. Mr.Munson would like to receive a copy of R&M's Hydrology Report.He was interested in their prediction of·winter ice conditions. Mr.Stackhouse commented that he felt that one of the biggest ·problems in the study was the fact that ADF&G hadn't published a procedures manual for the fisheries study yet.He was·.also concerned that one person from ADF&G wore two hats;he worked on the Susitna project and was also involved in the state permitting process. Mr.Stackhouse was .very concerned that APA had not filed a preliminar,y penmit yet•.He co~ented that withput the permit the F&WS has no Qfficial position to initiate a formal scoping process under their normal NEAPA-FERC procedures. Mr.Munson commented that under standard conditions the state and federal F&WS'work together on Exhibit S. Mr.Stackhouse pointed out that they need to tie in with the work being done on transmission corridors and they also need to work with the Steering Conmittee. Mr.Stackhouse feels that time is the over-riding factor in the studies.For instance,if a railroad is constructed for the access method,it would cost an extra year. Mr.i~unson surrmed up his corrments on a recreational standpoint by pointing out that the reservoirs were not going to be good for fishing;that the Devil Canyon reservoir would provide some recreational boating,but that·the main uses for the reservoirs would be to provide access for hunting. I Mr.Stackhouse commented that he would like to see a copy of the instream flow studies. NOTES OF MEETING DATE:April 9,1981 PROJECT NUMBER:AAI 218 LOCATION:Bureau of Land Management,District Office,Anchorage ATTENDEES:Art Hosterman,lou Carufel,Gary Seitz,Bob War~~.John ~ego, BUM;Kevin Young,Acres;J.O.Barnes and R.J.Krogseng,TES SUMMARY OF DISCUSSION Mr.Barnes made a presentation coverin~the history of the Susitna Project and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority.He also covered the studies and reports that are being prepared as part of the .study •. Mr.Seitz wanted to know if .FERC was responsible for the EIS.He also wanted to knOW/ff FERC would be asking BLM for penmits or when BlM would get a chance to outline their requirements. Mr.Rego wanted to know if FERC would be the lead agency.The present permit is good for three P>years of studies ..After that construction pennits would probably be necessary. Mr.Rego stated that he would like to see all three access routes studied; the Denali route north,the south route to Devil Canyon and the north service road between both dams.He commented that their Mr.Beckley has built a lot.~ of roads and that he ought to take a look at the different routes. Mr.Hostennan wanted to know "what are the biggest problems?1t Also,what is the role of the State Fish and Game Department in the studies.He also wanted to know about Cultural Resources and how they were being"taken care of.Mr. Hostenman also asked about Human Resources and the Natives and their interests. Mr.Hosterman wanted to know if induced seismicity caused by.the weight of the dam and reservoir was being considered.Also asked the question of how much pennafrost was in the area and whether or not it was being studied. The group also felt that public participation in study changes was a good idea. It was also felt that I'if you are going to do one right this is .the one.'1--- Prepared by k "r:::p R.J.rogs . NOTES OF MEETING DATE:April 9,1981 PROJECT NUMBER:AAI 218 LOCATION:Alaska Department of Fish &Game,333 Raspberry Road,Anchorage ATTENDEES:Carl Yanagawa,Regional Supervisor,Habitat Protection;Kevin Young,Acres;J.D.Barnes and Robert J.Krogseng,TES SUf>1MARY OF DISCUSSION: Mr.Barnes gave a short presentation outlining the histo~of the Susitna project and the role of Acres and TES in the present studies being conducted for the Alaska Power Authority. Mr.Yanagawa outlined the state penmit system inwhi'ch Mr.Trent is still the State Coordinator for the Department of Fish and Game for permits,although Mr.Yanagawa issues the pennits.Mr.Trent gathers the data and other infonna- tion that Mr.Yanagawa uses to issue the permits~The nonmal procedure is for Mr.Yanagawa to get a consensus from the different departments to help make the final decision. Mr.Yanagawa commented that he is presently short-handed in his department.He has a position number but no funding for it. Mr.Yanagawa had some questions about the access roads.He especially wanted to know when the road was going to be used.He said the Department .of Fish and Game would be prepared to make recommendations and trade off in regards to the access roads,but they did not have any real hang-ups about them. As a result of a decision made in Juneau in March,Mr.Yanagawa will not be a member of the Steering Committee.The policy of the department is that Mr. Trent is the coordinator forADF&G.The coordinator helps make the departments decisions.Mr.Trent is the only one who can raise official ouestions on the Susitna project. Drawing from his pipeline experience,Mr.Yanagawa commented that this was the wrong job -for a total preservationist.because sometimes you just have to get in and do your best to find the best route or method available and go with that, that not everything will be perfect~He recorrmended getting in and looking at routes early•.Sometimes a prob1emcan be solved by just moving the road 20 feet left or right. Mr.Yanagawa also feels that you need to keep asking yoursel f "if you spend another million dollars.how much more infonnation are you going to get"? He also feels that it is important to make everyone aware of the assumptions that you are making up front. Mr.Yanagawa also feels that you need to pick a starting place.because you cannot wait for all the answers to come in before you start. Also.drawing on his experience in building the pipeline,Mr.Yanagawa recommended forgetting about building a constrcution camp for temporary use and go ahead and design for permanent use.because you will save money in the long run. Prepared by_~--:;---:,:'f"'F~_~~_ ..... ..... NOTES OF MEETING DATE:April 10.1981 PROJECT NUMBER:AAI-21B LOCATION:University of Alaska.Arctic Enviromental Infonnation and Data Center.707 A Street.Anchorage.Alaska 99501(907)279 -4523 ATTENDEES:William J.Wilson.Fisheries Biologist AEIDC;Kevin Young.Acres; J.O.Barnes and R.J.Krogseng.TES. SUMMARY OF DISCUSSION: Mr.Barnes gave a short presentation covering the history of the Susitna Project and the role Acres and TES have in the present study being con- ducted for the Alaska Power Authority. Mr.Wilson was the project Leader for the Terror Lake project on Kodiak Is- l.and,and he discussed his experience in filing the FERC license application. Mr.Wilson was concerned about the slow start by ADF&G on the fisheries study. He felt that FERC's immediate reaction will proba~ly be to reject.the application and ask for more infonnation.He also felt that organizations like "S us itna Now"should be aware of this and be expecting the request for more information. Mr.Wilson feels that some of the fishery'stu9Y tasks will require alot of work.because some drainages in the Susitna basin do not have very much that is known about them. Mr.Wilson also commented that the instream flow studies may be a problem. because there is not much expertise available capable of doing the studies. On the Terror Lake Project Mr.Wilson said that they used joint participation where USGS.F&WS and AEIDCcrew members walked the streams together to pick out the study sites.because you can't pick them off from a map.Mr.Wilson feels that you have to know what the project is going to do to the stream flows and that incremental instream flow st~dles will give you that flexi- hi lity. Mr.Wilson commented that FERC would like to see an agreement between State and Fe.deral agencies over policies and requirements • As a member of the Susitna Hydroelectric Project Steering Committee~Mr. Wilson is concerned about the lack of infonnation on what is going on. He felt that it took too long to hear back on the Steering Committee1s comments on the procedure manuals~and that Acres should have responded sooner.Mr.Wilson also felt that the Steering COIl111itteeshould have seen the access road report earlier.He feels that preliminary infonnation should be made available to the Steering Committee ~s soon as possible. Mr.Wilson feels that Acres should publish more data in a IIthis is what we found ll format and not just IIthis is what we conclude ll • Mr.Wilson feels that the S~eering Committee should be a competent and helpf~l sounding board for the project.He feels that the Steering Committee can help save steps by pointing out pitfalls and other regulation mandates that need to be complied with as part of their advisory capacity.The Steering Committee cannot playa part in policy decisions~but they can give feedback on what was discussed to both sides. As part of a University of Alaska policy.Mr.Wilson would like to see more knowledge made available to the public.He would also like to see a centra- lized depository or library of information on the project that would make available the procedures manuals.maps •.photos.charts.diagrams.~nd .reports from the project. Mr.Wilson is also interested in seeing an informal Steering Committee meeting at Acres to provide an opportunity to open a dialogue with the Acres engineers. Prepared by 1Ct-7R.J.O'Kro ~~...-~-.-----'----~------~--~,--..-.-,-.------_._--.---~~-.~_._---_._-----------~----------------- NOTES OF MEETING DATE:April '10,1981 PROJECT NUMBER:AAI 218 ,-LOCATION:Alaska Division of Natural Resources,323 East 4th Avenue,Anchorage ATTENDEES:Al Carson,Deputy Director,Division of Research and Development, DNR;Kevin Young,Acres;J.D.Barnes and R.J.Krogseng,TES SUMMARY OF DISCUSSION: Mr.Barnes summarized the ideas and concerns that had been expressed during the series of meetings with the various agencies. ..... .- -- ..- The primary request from those who were also me.mbers of the Steering Committee was the request to get information to the Steering Committee in time for them to revi ew it before the meeti og. Also high on the 1ist was the desire for a central depositqry at the 1ibrary where all of the information would be available to more people. Not everyone was knowledgeable about access roads;more information has to be distributed to get peopl e up to speed.It shoul d also be understood that some areas are incremental,that some minor impacts may work together to cause a major impact.It is also felt that it is important to send out the criteria on objectives that are to be used in making decisions to the Steering Conmi,ttee members and ask for their'corrments on the fitness of the criteria. It is also important to get the ground rules set up before a dispute has started in order to avoid tunnel vision or having people argue about different parts of a question • There is still some confusion on how the fERC process works.It also appears necessary to get docketed or to put in a preliminary license application which will also authorize the Fish and Wildlife service to become involved in the study. Mr.~arson said he wo~ld be willing to help reinforce any concerns such as eng i neeri ng disputes that may a ri see Mr.Carson commented that he liked his meeting with APA~Acres and TES.He felt that it was open and not defensive.He also said that he is willing to start having Steering Committee meetings for discussion of problems,instead of fighting over problems. Mr.Carson would like to see reports sent to the Steering what is happening. a copy of the Acres and TES monthly progress Committee because it provides an overview of, Mr.Carson said the Steering Committee would like to know the decision making time lines.They also would like to know when studies and reports come in. Mr.Carson said that a criti~al need which he feels needs attention is the need for an understanding of technical,engineering,and socio-economic in- formation,fed together in a hol~stic "approach to the whole problem.He said that we need to inter-mesh ideas before people such as engineers have a vested interest in their design. Mr.Young explained how he works closely with the design engineers to bring ~nvironmental and social concerns into the design at an early stage to t~ to avoid future problems. Mr.Carson cOllTnented on the need to get input from the Steering Committee members before certain design milestones are reached. Mr.Carson said he would like to see EIS scoping procedures and activities used in solving some of the problems. Another suggestion Mr.Carson made was for Acres and TES to touch base with the Steeri ng"Commi ttee wi th a conceptual type outl i ne.To as k the Steeri ng Committee members lido you think this wil]do it?"uwill it achieve our purpose?·'He feels it is important to make sure you are using the right process before you go out and do all the work. Mr.Carson also commented that enlightened engineers are better to work with than biologists. Prepared by:~? .J.K seng -------------------- APPENDIX ElID CORRESPONDENCE RELATING TO DEVELOPMENT SELECTION "'"'" - ?\ililUllI\ APPENDIX 11.D DEVELOPMENT SELECTION In March 1981,the Development Selection Report was circulated to agencies for review and comment.This report compared various development scenarios within the l"1iddle and Upper Susitna Basin as well as alternatives outside the basin. The following are comments received on the Development Selection Report. Correspondence is presented primarily in chronological order.However,in some cases,a response to a letter directly follows the letter to facilitate an understanding of the flow of communication.This results in an interruption in the chronological sequence. j_""""""'""'F Susitna Hydroelectric Project Steering Committee Review of Potential HYdroelectric Development Sites ·-----, I : .,~.".~~.~1 !,:;:~,>,-~I :'i ';"j~'.!I ._~~.;'J:.:.'!~:-J I Mr.Al Carson Chairman,Susitna Hydro Steering Committee Department of Natural Resources 619 Warehouse Drive Suite 210 Anchorage,Alaska 99501 Dear Al: November 14,1980 P5700.11 .74 T.546 ~I Thank you for the opportunity of meeting with the Steering Committee on November 5,1980.I personally found it disappointing that my objective of establishing a workshop atmosphere where the members of. the Steering Committee could have a positive input into our selection of candidate hydro sites did not materialize.However,I realize that our objectives for this component of the Susitna studies may not have been adequately explained.In this regard I have attached a further explanation of our objectives as prepared by Robert Mohn of APA. I have accepted your suggestion that the most efficient means of obtaining input from the Steering Committee is to 1)identify in-house the short list of candidate sites we propose for further study;2)present this list to the Steering Committee for review and comment,and 3)incorporate these comments into our final selection and review. Presented on Table 1 is our short list of c~ndidate sites proposed for further study.As mentioned on November 5 it is essential for planning purposes to retain 4-6 sites within each of the size categories listed. These sites were selected from the list presented on Table 2.Table 2 represents sites that have passed through our r.ough economic and environmental screening.Although I realize that the Steering Committee disagreed with our rough screening criteria it is my opinion that using this criteria allowed us to eliminate the least environmentally acceptable schemes . ..:,-'-'".;..~".~...-.'-:..n .:''';~.~... Mr.Al Carson Chairman,Susitna Hydro Steering Committee November 14,1980 page 2 I would appreciate recelvlng the Steering Committee's review and comments on the sites presented in Table 1.If for any reason you find that any of these sites are totally unacceptable.I request that you recommend a replacement of similar size from the sites listed 'in Table 2.This replacement is essential so that we can retain 4-6 candidate sites in each size category.Information relating to location and design para- mete~for each site was included in the information packets distributed prior to our November 5 meeting. Trusting this approach meets with your approval. Coordinator KRY/jmh Attachments """ -. Table I Candidate Sites for Future Study <25 MW Tustumena Allison Creek Silver lake Strand1 ine Lake 25-100 MW Snow Hicks Cache Keetna Talkeetna-2 Lower Chulitna >100 MW Chakachamna Johnson Browne Land Tokichitna Table 2 Sites Passing Rough Screening Size <25 MW Strandline L. Lower Beluga Lower Lake Cr. All ison Cr. Grant Lake McCl ure Bay Upper Nellie Juan Power Creek Si 1ver Lake Solomon Gulch Tustumena 25-100MW Whi skers Snow Coal Kenai Lower Chul i tna Gerstl e Ohio Tanana R. Lower Chulitna Bruskasna Cache Kantishna R. Greenstone Upper Beluga Talkeetna 2 Coffee Granite Gorge Gulkana R. Keetna Klutina Sheep Creek Bradley Lake Skwentna Hick's Si te Talachulitna Lowe >100 MW Lane Tokichitna Yentna Cathedral Bluffs Johnson Browne Tazilna Kenai Lake Chakachamna ALASKA PO\VEIl AUTIIORITY MEMORANDUM TO: FROM: Susitna Steering Conmittee Members .~/RobertA.Mohn ivr'7 Director of Engineer4ng Alaska Power Authority DATE: SUBJECT: November 25,1980 Environmental screening of hydroelectrjc sites There has been some measure of frustration and disappointment on all sides associated with the attempt by Acres American to solicit input from the Steering Committee at the committee's last meeting.It seems to me that an important factor in the lack of success may stem from misunderstanding or uncertainty about this exercise in relation to an "alternatives study~. As you probably remember,the original Acres plan of study (POS)called for a study of alternatives to Susitna as the primary element of Task 1.Information about alternatives was to be developed,a screening mechanism was to be employed to narrow the range of acceptable options,and the Susitna project was to be compared against the preferred alternative.This work was to be conducted in parallel with the detailed studies of the Susitna project,and its goal was to formulate several optimized "without Susitna ll plans.In other words,Task 1 was meant to be a thorough search for a plan that would be preferable to Susitna development. The Power Authority requested supplemental funding to adequately fund Task 1 after some early criticism of the funding level and study scope.The requested $1.3 million was appropriated but with the caveat that the alternatives study would be performed by someone other than Acres.The Governor 's4-person policy review committee (Ulmer,Lehr,Quinlan and Conway)selected BatteTle to do the work. The elimination of Task 1 from our study 'plan left a significant hole. This was the case because information that was to be developed in Task 1 was critical to the formulation of the preferred Susitna basin development plan and to the economic evaluation of the Susitna plan.River basin planners cannot formulate an optimal Susitna plan without knowing what the remainder of the Railbelt power system components are likely to be,and the economic analysts cannot evaluate beriefits and casts without having a "without Susitna ll plan to compare to. So,the Power Authority and Acres responded to the termination of Task 1 by augmenting the design development work in Task 6~This permitted ,the Susitna study to stay on track by incorporating that portion of Task 1 needed for Susitna plan formulation.The objective of this work is not to formulate an optimal set of alternatives;that is being done by Battelle.Instead the purpose is to gather information about likely components of a future Railbelt power system as a frame of reference for Susitna project formulation. ALASKA POWER.AUTIIORITY MEMORANDUM TO:Susitna Steering Committee Members DATE:November 25.1980 It is in this gathering of information about likely system components and in establishing the frame of reference that your assistance has been sought.To reiterate.the exercise is in support of Susitna'project formulation;it is not meant to replace the Battelle alternatives study or be the final word on alter- natives. i 323 C.4TH A VENUE DIVISIOAIOFRESEARCH&DEVELOPMENT i ANCHORAGE.ALASKA 9950' 279-5577 .~ ·~\P .:I·~ ~I '- ....J :,..II \:=J :J DIi:P~\.IlT~IENT 0.'NATUR.;..\I.RESOURCES / I JAY .s:HAIIIIO"D,'OY!'lIfJ1 I / December 11,1980 Don McKay U.S.Fish &Wildlife Service 733 W.4th Ave.,Suite 101 Anchorage,Alaska 99501 Dear Mr.McKay: Enclosures Sincerely, Al Carson,Chairman Susitna Hydro Steering Committee Eric Yould -A.P.A. Kevin Young -ACRES cc:. Enclosed please find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You will recall that we discussed this with Mr.Young during our afternoon session on Novembe.r 5,1980. There.isalsoa memorandum from Robert Mohn of the .Alaska Power Authori\~~hfllSW!!R'"I descrlbes why A.P.A.has contracted ACRES to do thlS task..1 A..TMOR:TY.'1/-- ;SUS/TNA " Please review the documents as explained in Mr.Young1s letter and ~~1it P57;;;-l ; your comments to me either in writing or by phone by December 31,1~-=-_~~~-~'~~::.r··1 ;:'''~:':-'l.i::i-';;:I~'J'lf)'I i;."-~.::.'"I .,...:~~.~-'-"':~"-------' I 7'i.,..:·f ~.~I' i ' . .~:l...I I ' ;:.~..~1 ~1.~I ;",";'''~,,!_;_::I;--:~·~-1 ..!,---,~,,-;KC.:,",';;'..,IJ ;'-.,:_...--..-....-'.~·_1- .--'~'L;_:.'·-:L~i.r .~.~-.~-'-'.':"t!dVi :----':::<:t.< ~:~..----~---,,.5'.:..---'"1"j '.;:•. ;-"-;--~;)j/J~"1 . ;.'!·.-l~iJl-1 '-;-r-H-F~r:l'-;. i.=!xcr~Ril L~tp .;_~:'f~.bbcrli..'sm..;(Ii~I !iL&.L...!-i:--I'''=~'fJ1rf.~.L?Ii 2--:.f_,J ;!I ,------~.~i ii'7)rILE j _., ~, J)H~~IlT~IENT 0 ..'NATURAl..R":SOURCES I , I / ..-..-, ..- -0-,; ! I, DIVISION OF RESEARCH &DEVELCPMENT ! JAr.t HAIIIIO/ID.GDVEIIIOI 323 E.4TH A VENUE ANCHORAGE.ALASKA 99501 279-5577 December 11,1980 Tom Trent AK Department of Fish &Game 333 ~pberry Road Anchorage,Alaska 99502 Dear Mr.Trent: Enclosed pl ease find a 11/14/80 letter from Kevin Young of A.cres American concerning review of potential hydroelectric sites.You will recall that we discussed this with Mr.Young during our afternoon session on November 5,1980. There is also a memorandum from Robert Mohn of the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents as explained in Mr.Yo~ng's letter and forward your comments to me either in writing or by phone by December 31,1980. Sincerely, O\~ Al Carson,Chairman Susitna Hydro Steering Committee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES JAr.t HAMM01lD.'OVE,,ID' f / I ! I ,1, / Ii 323 E.4TH A VENUE l ANCHORAGE.ALASKA 99501DIVISIONOFRESEARCH&DEVELOPMENT ,..r .-, -•.'/I \ ,.;.;.;, :.,\:\;'.~.:'~-\in'____ ._,_.'-i l~i..J :J ))E~\IlT~IENT 0 ..'NATUR.41.RESOURCES 279-5577 December 11,1980 John Rega Bureau of Land Management Anchorage District Office 4700 E.72nd Avenue Anchorage,Alaska 99502 Dear Mr.Rego: Enclosed please find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You.wi.l1 recall that we discussed this with Mr.Young during our afternoon session on November 5,1980. There is also a memorandum from Robert Mohn of the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents as explained in Mr.Young1s letter and forward your comments to me either in writing or by phone by December 31,1980. ,~Sincerely, (JQ~ Al Carson,Chairman Susitna Hydro Steering Committee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES JAr s.HAlIMOIIO,SOVEIIIOI UEP,,\.RT-'IENT 0.'NATURAI~RESOURCES DIVISION OF RESEARCH &DEVELOPMEM" December 11,1980 Bob Lamke U.S.Geological Survey Water Resources 733 W.4th Ave.,Suite 400 Anchorage,Alaska 99501 Dear Mr.Lamke: , i /!323 E.4TH A VENUE I ANCHORAG~ALASKA 99501 279-5577 Enclosed please find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You will recall that we discussed this with Mr.Young during our afternoon session on November 5,1980. There is also a memorandum from Robert Mohn of the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents as explained in Mr.Young's letter and forward your comments to me either in writing or by phone by December 31,1980. Sincerely, 01~ Al Carson,Chairman Susitna Hydro Steering Committee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES I j I I / -~r~...-, _.':,..~~-/j \ . .,\!n,' _'.,j UU \_ Uln·.:\.IlT~IENT 0 ..'NATURAl..R':SOURCES DIVISION OF RESEARCH &DEVELOPMENT December 11,1980 Bill Wilson or Chuck Evans Arctic Environmental Information and Data Center (U of A) 707 nAn Street Anchorage,Alaska 99501 Dear Messrs.Wilson &Evans: t J f JAr s.HAMMOIID,'OrflNO' 323 E.4TH A VENUE ANCHORAGE,ALASKA 99501 279-5577 Enclosed please,find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You will reca 11 that we discussed this with Mr.Young during our afternoon session on November 5,1980. There isalso a memorandum from Robert Mohn of the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents'as explained in Mr.Young's letter and forward your comments to me either in writing or by phone by December 31,1980. Sincerely, OJ'~ Al Carson,Chairman Susitna Hydro Steering Committee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES ._----~--------------------- JA r 1 HAMIiOI/O.'Ovell/O' ·-,..!-~......... !~.J."...t".f.:.\ .~,~"~~.~L~~ J)EP.\.HT1UENT 0'-NATURAI~R ..:SOURC£S DIVISION OF RESEARCH &DEVELOPMENT December 11,1980 Dave Sturdevant Department of Environmental Con~vation Poucn 110 11 Juneau,Alaska 99811 Dear Mr.Sturdevant: i f / ! /, /323 E.4TH A VENUE I ANCHORAGE.ALASKA 99507 279-5577 Enclosed please find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You will recall that we discussed this with Mr.Young during our afternoon session on November 5,1980. There is also a memorandum from Robert Mohn of the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents as explained in Mr.Young's letter and forward your comments to me either in writing or by phone by December 31,1980. Sincerely, ()j~ Al Carson,Chairman Susitna Hydro Steering Crnnmittee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES DIVISION OF RESEARCH &DEVELOPMENT Inn~\.IlT~'ENT eu"~ATURAI.R":SOURCES 279-5577 323 E,4TH AVENUE ANCHORAGE.ALASKA 9950' ,l J JAr .£HAMMDIID.'OYCIIIOI / / n ,...,...,---,...~njl;~l\!-,,"';'i~'·.<,';Ii',,\\\\!'(U\,,".,I •\.....'\I \'\:I,)\~:I ~\,.,;..\....u tLrubLrD\::)U~Lru /~:;'~;? :~1;i ~vU - I~ December 11,1980 Larry Wright or Bill Welch Heritage Conservation and Recreation Service 1011 E.Tudor Road,Suite 297 Anchorage,Alaska 99503 Dear Messrs.Wright &Welch: Enclosed please find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You will recall that we discussed this with Mr.Young during our afternoon session on November 5,1980. There is also a memorandum from Robert Mohnof the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents as explained in Mr.Young's letter and forward your comments to me either in writing or by phone by December 31,1980. Sincerely, 01~ Al Carson,Chairman Susitna Hydro Steering Committee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES (n':;? '\.~;U nEI~\IlT.\IENT 0 ••NATURAI4 R~SOURCES DIVISION OF RESEARCH&DEVELOPMENT December 11,1980 Brad Smith or Ron Morris National Marine Fisheries Service 701 "C"Street,Box 43 Anchorage,Alaska 99513 Dear Messrs.Smith &Morris: ~ / ! I JAr s.HAIIMOND.SOYEINO' /323 E.4rH AVENUE j ANCHORAGE.ALASKA 99501 279-5577 Enclosed please find a 11/14/80 letter from Kevin Young of Acres American concerning review of potential hydroelectric sites.You will recall that we discussed this with Mr.Young during our afternoon session on November 5,1980. There is also a memorandum from Robert Mohn of the Alaska Power Authority which describes why A.P.A.has contracted ACRES to do this task. Please review the documents as explained in Mr.Young's letter and forward your comments to me either in writing or by phone by December 31,1980. Sincerely, ~~ Al Carson,Chairman Susitna Hydro Steering Committee Enclosures cc:Eric Yould -A.P.A. Kevin Young -ACRES UNITED STATES DEPARTMENT OF THE INTERIOR GEOLOGICAL SURVEY Water Resources Division 733 W.Fourth Ave.,Suite 400 Anchorage,Alaska 99501 July 27,19B1 RECEIVED .1Ul ))1981 ALASKA pow~::..:....:~:~()kITY Al Carson State of Alaska Department of Natural Resources 323 E.Fourth Avenue Anchorage,Alaska 99501 Dear Mr.Ca rson: I have reviewed the Draft Development Selection Report for the proposed Susitna Hydroelectric Project as requested in the APA transmittal of June 18,19.81.The review was limited tathe evaluation process used by Acres,the relative impacts of several a1 ternative development pl ans of SusHna hydroelectric resources,and the conclusion that the Watana- Devil Canyon plan ;s the preferted basin alternative. There were no problems involved in understanding the selection process used by Acres and there were enough data and information presented to compare the final candidate (alternative)plans.The relative impaEts of the candidates were presented in an understandable and credible manner. Althoughenlyaqualitative eva 1 ua tion of impacts is presented'(pendi ng reports of on-going studies),a reasonable conclusion is that the Watana- Deyil Canyon pl an is the preferred candi da te for Susitna hydroel ectri c development. ".j//U'"},I:'"),-!-V1,A,/.,L-Ci;4-'/U iRobert D.Lamke cc:David D.Wozniak,Project Engineer,APA,Anchorage,AK I .•onmentQI Information and Data Center 707 A Slreet Anchorage.Alaska 99501 PHONE (9071279-4523 UNIVERSITY OF ALASKA August 4,1981 Dave Wozniak Alaska Power Authority 333 W.4th AVenue,Suite 31 Anchorage,AK 99501 Dear Dave: RECt:/VED .....rfr"C'1981',,"',J :.; ALASKA POWER AUTHORITY Per your request to the members of the Susitna Steering Committee,I have quickly reviewed the Development Selection Report prepared by Acres.In general I found it logical in approach and complete in re- gards to the relevant factors one should evaluate when reducing multiple options. I ha~only the following specific comments: 1.The location and environmental effects of developing borrow material sites is not well documented and incorporated into the first part of the report.Enormous qunatities would be required for most of the dams,and the removal,stockpiling, and transport of this material could be a significant factor influencing the decision-making process. 2.Significant efforts are currently being expended in environ- mental study of this region,the results of which are not yet available.Factoring this new knowledge 'into the decision- making process could have influenced the nature of the final scheme;or is the current environmental study effort geared only toward the effects of the "selected plan (page 9-1)"and not for input to the overall selection process?In general I found the environmental effects of the alternative options addressed very superficially. I hope my comments are of interest. Sincerely.i ':Yh ~(c ,_.--:9 .)/'L'("'-- William J.Wilson Supervisor,Resource and Science Services Division Senior Research Analyst in Fisheries WJW/g cc:Al Carson United States Departm~nt of the Interior NATIONAL PARK SERVICE ALASKA STATE OffiCE IN R.EPLY REFER.TO: l201-03a 334 W~st fifth Avenue,Suite 250 Anchorage,Alaska 99501 AUG 5 1981 RECEIVED !\UG ?1981 N.ASKA POWER AUTHORITY ~.~::J........~,~~ :"1·..•. Mr.David D.Wozniak Susitna Hydro Project Engineer Alaska Power Authority 333 West 4th Avenue,Suite 31 Anchorage,AK 99501 Dear David: In response to your request I have reviewed the Draft Devel- opment Selection Report for the Susitna Project.Based upon the information presented in the report,I would judge the evaluation process to be satisfactory.However,I would not want to recommend or otherwise comment on a prefe'::'red basin alternative prior to the completion of ongoing studies which will further quantify the anticipated environmental impacts. I assume the final report will refl~ct a more precise com- parison of environmental impacts for the dam sites under consideration. An additional item of interest which should perhaps be included in the final report is a comparison of the expected life of the project for each alternative dam site considering the effect of silt accumulation in the reservoirs. Thank you for the opportunity to review the report.The above comments are my own and should not be interpreted as representing the official position of the National Park Service. Sincerely, -~"\..'.ll-f£WJ Ull C,)17~ Larry ..Wrlght . Outdoo Recreation Planner Save Energy and Yau Sen'e America! / ! I i I 437 E Street Second Floor Anchorage,AK 9950: :;OU1l1C/Nlh';'1 fiifi.'f",.;,.",.1 ?,:':=_ij~D j !, i PO.8m 1207 Soldotna.'\iaska 99669 (9071 ~52 5210 P.O.Box i064 Wasilla,Alaska 99687 (907)375·5038 lSR1 Dave Wozniak Project Engineer Alaska Power Authority 333 W.4th Avenue.Suite 31 Anchorage,Alaska 99501 Dear Mr.Wozniak: August 14,1981 We have reviewed sections 7 and 8 of the Susitna Hydroelectric Project Development Selection Report (second draft June 1981).We find that the plan selection methodology used in section 8 meets the objectives of determining an optimum Susitna Basin Development Plan and of making a preliminary assessment of a selected plan by an alternatives comparison. The increased emphasis over previous analyses of the environmental acceptability of the alternatives is good. At this time.this Department does not endorse any particular plan.We would.however,recommend the Steering Committee openly discuss the Watana Dam -Tunnel option because of its reduced environmental and aesthetic impact. Thank you for the opportunity to review this document.We appreciate your effort in soliciting Su-Hydro Steering Committee involvement.If you have any questions regarding these comments please contact Steven Zrake of this office. Sincerely. fi~r/h~=- Bob Hartin RegIonal Environmental Supervisor cc:Steve Zrake Dave StudL'vant Al Carson -DNR BH/SZ/mn l~""~··.i..r·..t•...[~..'.,.;..~-~-t~ti Mr.Lee Wyatt Planning Director Matanuska-Susitna Barough Box B Palmer,Alaska 99645 Dear Mr.Wyatt: October 21,1981 P5700.10 Susitna Hydroelectric Project Development Selection Report As you know,Acres J1merican,Incorporated is under contract to the Alaska Power Authority to conduct a feasibility study and prepare a Federal Energy Regulatory Commission (FERC)licen.se application for the SusitnaHydro- electric Project.The scheduled date for submission of the application is in June of 1982. Federal law and FERC regulations require that the reports supporting the FERC application be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.This coor- dination must be documented in the license application. A great deal of coordination has taken place at agency staff levels by dir- ect participation in studies or by participation in committees and task groups.This input,however,has been primarily by staff and may not nec- essarily reflect the views of the agency.For this reason,we are conduct- ing a pa~allel formal coordination process,by requesting agency comments on key study outputs.The plan of study was the first document coordinated in this manner.Over the next year,there will be several more.This par- allel process will affect the other coordination activities of the study. At this time,we request that the ft'latanuska-Susitna Barough review the attached Report,particularly in the areas impacting on the environment. ACRES AMERICAN INCORPORATED Co,",sulting Engineers The Liber~;'B<!nk Buiio'''9 Main at Court E\J~!a!o.NoS>'.'.York 14202 Te ex Q~·642:i·e-RES E:UF Development Selection Report - 2 October 21,1981 Your prompt attention to this matter will enable us to continue planning the best possibledevelopnent for all interests.A response within thirty days of receipts would be greatly appreciated.Please send a copy of your comments to: Mr.Eric Yould,Executive Director Alaska Power Authority 333 West 4th Avenue Anchorage,Alaska 99501 Very truly yours, JDL:jgk ~ cc:Eric,Yould,Alaska Power Authority John U.Lawrence Project Manager ,.... Preceding letter Sent To: ..... Mr.Lee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer AK 9%45 Mr.John Rego Bureau of land Management 701 C Street Anchorage,AK 99501 Mr.Tom Barnes Office of 'Coas~al Management Division of Policy Development and Plann"j ng Pouch AP Juneau,AK 99811 Mr.John E.Cook Regional Director National Park Service 540 West Fifth Avenue Anchorage,AK 99501 Mr.Ernest W.Mueller Commissioner Alaska Department of Environmental Conservation Juneau,AK 99801 Ms.Lee McAnerney Department of Regional Affairs Pouch B' Juneau,AK 99811 Mr.Ronald O.Skoog COl1Vllissioner Alaska Department of Fish and Game Juneau,AK 99801 Mr.Keith Schreiner Regional Director U.S.Fish and Wildlife Service 11011 E._Tudor Road Anchorage,AK 99503 Colonel lee Nunn District Engineer U.S.Army Corps of Engineers P.O.Box 7002 Anchorage,AK 99510 Mr.John Katz Alaska Department of Natural Resources . Pouch M Junean,AK 99811 Mr.Robert Shaw State Historic Preservation Office Alaska Department of Natural Resources 619 Warehouse Avenue Anchorage,AK 99501 Regional Administrator U.S.Environmental Proection ,Agency 1200 South Avenue Seattle,WA 98101 Mr.Robert McVey,Director Alaska Region ,National Marine Fisheries Service P.O.Box 1668 Juneau,AK 99802 RECEIVED {lO'.}13 1981 i\ove:;",Jer S,1951 P5700.06 Alaska Dept.of Fish &Game Sport Fish/susitna Hydro Mr.Ronald O.Skoog COl11Tlissioner State of Alaska Department of Fish and Game Juneau~Alaska 99801 Susitna Hydroelectric Project Development Selection Report Dear Mr.Skoog: As you know~Acres American Incorporated is under contract to the Alaska Power Authority to conduct a feasibility study and prepare a Federal Energy Regulatory Commission (FERC)license application for the Susitna Hydro- electric Project.The scheduled date for submission of the application is in June of 1982. Federal law and FERC regulations require that the reports supporting the FERC application be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.This coor- dination must be documented in the license application. A great deal of coordination has taken place at agency staff levels by dir- ect participation in studies or by participation in committees and task groups.Th is i nput ~however~has been pr imari ly by st aff and may not nec- essarily reflect the views of the agency~For this reason~we are conduct- ing a parallel formal coordination process by requesting agency comments on ~ey study outputs.The plan of study was the first document coordinated in this manner.Over the next year~there will be several more.This parallel process will affect the other coordination activities of the study. At this t;me~we request that the Department of Fish and Game review the attached Report,"Development Selection Report"~particularly in the areas impacting on the'fish and game resources. ACRES AMERICAN INCORPORATED ConSU':;c->J Eng,ncers The lit'''!,!l~"k Bui!c!"'9.I.!ain at Court 3u:fa'C'r;=...'ycrk1~202 veve:opment Se:ection kepor L -/r·iOVe:"De ....9,1961 Your prompt attention to this matter will enable us to continue planning the best possible development for all interests.A response within thirty days of receipts would be greatly appreciated.Please send a copy of your comments to: Mr.Eric Yould 9 Executive Director Alaska Power Authority 333 West 4th Avenue Anchorage 9 Alaska 99501 Very truly yours 9 Q'tJ-/lm ~~/tiip/ ~n D.Lawrence JOL/MMG:jgk Project Manager cc:Eric Yould 9 Al aska Pawer Authority Mr.Thomas Trent 9 Department of Fish &Game ACRES AMERICAN INCORPORATED WILLETT WITTE BERRY HAYDEN LAMB LAWRENCE SINCLAIR VANDERBURGH ',-'1 \ CARLSON FRETZ JEX LOWREY SINGH HUSTEAO BOVE CHASE rv~/.// ~/~,.~ // December 4,1981 P5700.11 .92 T .1330 Mr.Lee Wyatt Planning Director Matanuska-Susitna Barough Box B Palmer,Alaska 99645 Susitna Hydroelectric Project Document Transmittal Form Dear Mr.Wyatt: Enclosed is a document transmittal form which should have accompanied our package dated November 10 containing copies of the Developnent Selection Report and its appendices.The document transmittal form is part of a newly-implemented procedure at Acres which is intended to verify the arrival of documents shipped via various carriers and thus alleviate as quickly as possible any problems which may arise due to documents being misplaced during transit.. If you have any questions,please do not hesitate to call. Sincerely yours, ~e:Y7J~ ~John D.Lawrence .Project Manager JEM/jh Enclosures ACRES AMERICAN INCORPORATED T""J~LlbE="~::r'eG''';~8 ....,f::.~;'.~2·r.at C0urt 2 ..../1 ;;'0 ~;f-...Yo·io"'-'LQ2 Mr.Lee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer AK 99645 Preceding Letter Sent To: Mr.Keith Schreiner Regional Director u.S.Fish and Wildlife Service 11011 E.Tudor Road Anchorage,AK 99503 .'''''' Mr.John·Rego Bureau of Land Management 701 C.Street Anchorage,AK 99501 Mr.Tom Barnes Office of Coastal Management Division of Policy Development and Planning Pouch AP Juneau,AK 99811 Mr.John E.Cook Regional Director National Park Service 540 West Fifth Avenue Anchorage,AK 99501 Mr.Ernest W.Mueller Commissioner Alaska Department "of Environmental Conservation Juneau,AK 99801 Ms.Lee McAnerney Department of Regional Affairs Pouch B Juneau,AK 99811 Mr.Ronald O.Skoog Commissioner Alaska Department.of Fish and Game Juneau,AK 99801 Colonel Lee Nunn District Engineer U.S.Army Corps of Engineers P.O.Box 7002 Anchorage,AK 99510 Mr.John Katz Alaska Department of Natural Resources Pouch M Junean,AK 99~11 Mr.Robert Shaw State Hi:storic Preservation Office Alaska Department of Natural Resources 619 Warehouse Avenue Anchorage!AK 99501 R.egional Administrator U.S.EnvironmentalProection Agency 1200 South Avenue Seattle,WA 98101 Mr.Robert McVey,Director Alaska Region ,National Marine Fisheries Service P.O.Box 1668 Juneau,AK 99802 17 DEC·19ln }lr.[ric Yould Lxecutive Director Alaska Power Authority 333 W.4th Avenue &lchorage.Alaska 99501 Dear Hr.¥ould: Xr.John Lawrence of Acres American,by letter of November 9,1981,_ requested that the Fish and Wildlife Service review the Development Selection Report for the Susitna Hydroelectric Feasibility Study.We offer the following comments:. 1.711e decision-making methodology (selection process)does not pro- vide an equitable basis for comparison of all study el~ent8.lbe proble~that ve have identified is that at the time major decision points arc reached,information Is much more detailed in regard to engineering and economic factors than environmental considerations. We recommend that the process be modified so that all study elements are equal (scope and depth),before they are presented to the . decision-maker. 2.Although alternatives to Susitna are being studied separately by Battelle,cocparisons were drawn within the selection report.The comparison of Susitna development to alternative hydroelectric power development is stated as economic only.The eomparison to thermal generation is,although not noted as Buch,solely based on an econOlD.ic evaluation. In regard to sensitivity testing of the all the~al versus Susitna . power development options the report states (p.9-11),"A comparison of alternatives to Susitna is outside the realm of these studies ••••'· The following conclusion is,however,offered on p.9-1,tI •••the future development of Railbelt electric power generation soaTces should include 8 Susitna Hydroelectric Project."These statements are in apparent conflict. 1ne following statement addresses the Susitna development environmental studies and review (p.9-11),"Identifying compensation meaaures ,and the actual prediction of environmental impacts are the subject of ongoing studies.The results of these studies will be included in our 1982 feasibility report to be available prior to making the decision as to whether or not to proceed with FERC licensing."It should be noted that :J<uch of theinforrnat10n for inclusion in the feasibility report w11l be preliainary.It Is our opinion that the rudimentary nature o!this Info~tion ~ould preclude a crediblo impact analysis at that time. 7hank you for the opportunity to revi~and comment on the Design Selection Report. Sincerely, /SI S~HfnJr'.s~ Adfng ~~t Regional Director -cc:F~S-ROES.WAfS i\}!FS,Anchorage Quentln Edson,PERC LaYrence,Acres Amoriean - The preceding letter was received and reviewed.Although no formal response was prepared,our comments are as follows: (1)It was most efficient to determine if a site could technically be developed and it it would be economically attractive prior to collecting environ- mental information.Once a site passed the initial economic and engi- neering screening,full consideration was given to environmental consider- ations.Figures E.10.l and E.10.4 depict the selection process. (2)Environmental factors were considered when comparing Susitna to other sources of power.This information is included in an expanded form in Chapter 10,Section 4 of Exhibit E of the license application. (3)Th~chedule for filing the license application was developed fr~TI June 1982 to February 1983 to allow incorporation of additional environmental data and to refine the impact analysis and mitigation planning.In addition,the Alaska Power Authority will be funding continuing environ- mental studies. ------~----------~~~~~--~---~~---~---~~ RECEIVED JAN 04 1982 ACL,;"~;-".~"'ii jilbuitr'ORATED L7619(AAo-F)30 DEC 1981 ALASKA POWEF WTHORITY SUSITNA FILE P570CDirectur Desl"f-~r.Yculd: SEQU£f\:CE N ..6?~f.,/ Z Ii I ci I ' Oit:l:1 ~.: Ir.response to a fiOysuber 16,1931 letter frc.-n the ,\crcs Ame~fcan Inc.P ~~&::~!; f·:af,ager.Hr.John o.La\1renCe,we have the followinq coorn1ents concerning t·:ed __:~ $u~itn·l project reports.The reports reviewed include:1930 Eflvironr.;cnt l!~I~c~_ Su;;':;13ry Report (i1iC:Y 1981);Trans."'11ssion Une Corridor Screelling RC>i'\ort (S Pt§~~~~:\• 1?~1);and the Devs1or''\1<ent ~lecti(jn R~pQ>rt (Oetoner 1981)...l_i-:f-~D :-= ......I ;J (j";. Provi sian for ~ul tural resource fdeiit1ficat1on and ma l1ii 9f:ffi2r:t .arp~ars to·~~~;- apprcpriat.e ana adequate.l\lso.it would .appear that recrClatlofi 15 being --"-J ;,:-1- ad~oUdtcly'addressed b...·the ;)lannfn~,process..-,_._--:- ,..J ,.'IIPGi;'----.-- Ttlc:-Evaluation process descrit-ed in the !Jcvelopr-.ent Selection Ref-crt appc r9_~N~1 _ to bJ::very adeQuate.T!~is a?enc:y dces not recor;r,:cnd a particular tias in p W"~r so,;T I C'Clvt:'1opGent plan.l:o~~·::Yer.we de note on pa~e G-26 that the tunnel SChffi~1Is-D~'iL!-- recoJnir(;~l;Y.th~report 3.S t'·ein::enV1rQnr!entallj'superior.dlld hould pre.i"'~'Ie;;"'R "1-- Dany of the resuurc~villues curr~nt'.Y assoc1atc:d with the De"n Canyon.H-R"cl-- --j- It wuuld ce helpful to thf!r~~iJcr 1 f an indt!.X could be inc1udect with each ----:- rc.port or j1er:lap$prepared szr;arately for the entin~s(~r1es of rrojE:ct rei .~ts.:-- ~f'i::100.r.forward to.the (jp~r;rtun1ty to r~v1,,::w subs~quent prc,j..e.ct re;:crts..b .=!~~ addition to t'C1fi:J il~dud:::d in thG historfcl.l an<:archeolo!]ical,and rccr~t1 n ! \?ro~~s id<2)~t1fi€J for fun·:al coordination.thfs ~·;~ncy should p?rhaps a1s =r¥'FI\;E !- 1i 1cwd::c Hithin the \r!ater quslity and lise,~estl~et1cs arid land use srour;s ~BS \":.c-,'---- ~r.:t:lte:f£:stI2C in project r~lct~d recr(~tion i:~::'ucts that niH occur ~iU1in au<! {;-::ycild the:project.hour.dar,'!. .~1r.Eric Yould,Executive Alaska Powe~Authority 33~W.fifth Avenue Anchorage.,'\l~ska S?S51 j~J DouclasG.~arnoel cc: ':c,',;'~.Lil\.r''::iC(=,Acres f.:·;.:dcer.Inc ••5'o-J Ubertyt;~nk ~Idlcii~g,2-dfalo,-:::to: Y~;r~:.C')? I r ~_--.;; I - I!i:L ,--_ Mr.Douglas G.Warnock Assistant Regional Director Alaska Region National Park Service 540 West Fifth Avenue Anchorage,Alaska 99501 Dear Mr.Warnock: ~'arch 1,1982 P5700.11 T.1425 Susitna Hydroelectric Project I thank you for your December 30,1981 response to our request for review and comment on Susitna project reports forwarded to your agency. I am pleased that you are satisfied to date with our cultural resource identification and management,recreation planning and Development Selection evaluation process. In regards to the review of subsequent reports we are receptive to including your agency in the water quality and use,aesthetics and land use groups if you consider this information beneficial in performing your formal review of project related recreation impacts.We are ent10sing the 1980 Land Use Annual Report. KRY/jmh End osure xc:Eric You1d,APA ACRES AMERICAN INCORPORATED i·r .••r-c."..;:-._.:.,.::.,-p ...-.~.":-~""...;..,:'....: APPENDIX EllE CORRESPONDENCE RELATING TO MITIGATION PLANNING ~, - - APPEND·IXll .E MITIGATION PLANNING Mitigation planning for the Susitna Project has involved APA,its consultants, and the state and federal resource agencies.A Fisheries Mitigation Core Group,Wildl He Mitigation Core Group,and Fish and Wil dl ife Revi ew Group· were established.A Fish and Wildlife Mi,tigation Policy was developed,re- vised three times following receipt of comments,and finalized during the 1981-1982 period.Various mitigation options papers were also drafted, circulated for comments,and discussed in meetings with the agencies. This section contains correspondence and meeting notes of the above activities. Correspondence is presented primarily in chronological order.However,in some cases,a response to·a letter directly follows the letter to facil itate an understanding of the flow of communication.This results in an interruption in the chrohological sequence. It should be noted that correspondence and meeting notes,regarding the model ing workshops,are not included.Al though this workshop rel ates to mitigation planning,it also relates to ongoing studies.Hence,it is in the Additional Studies and Project Refinement section. SUSITNA WIlDLIFI MITIGATION TASK FORCE NOTES OF MEETING January 30,1981 Anchorage,Alaska Compiled by:Edward T.Reed Wil dl He Ecology 'Group Leader Terrestrial Environmental Specialists,Inc. The meeting was corrmenced at 9:00 a.m. Hr.Reed gave a brief introduction and requested that all participants (see attached list)introduce themselves and indicate the organization they represented,.In his introduction,Mr.Reed identified the major problem associated with the development of a Susitna wildlife mitigation program as .the fact that in some cases data collection will not be complete until after the submittal of a license application to FERC (July 1,1982).Thus the level of detail that can be incorporated into a program at the end of Phase I wi 11 vary among the various ~ components of thewildl ife studies,and in some cases there will be insufficient data available to develop a finely-·tuned mitigation plan . ...Carson asked what the relationship was between this meet ing and the Steering Committee comments on the Task 7 Procedures Manuals.Dr. lucid and Mr.Reed responded that,although mitigation planning was among the topics commented upon by the Steering Committee,this Task Force had been planned prior to the Steering Comnitteets comments and was not in response to the comments. Mr.Wozniak explained some of the history that preceded this meeting, including the role of the Steering Conmittee and indicated that this meet ing represented a formal consu Hat ion between the Power Author ity (including the Power Authority's representatives,i.e.Acres and TES) and federal and state agencies as called for by the ~ish and Wildlife Coordination Act. Mr.Reed presented a brief outline (attached)describing the organization and functioning of the task force.At the request of Mr. Carson,the word IIprocedureslt (Purpose of the Task Force,Item #1)was changed to "options". -2- dual role of Mr.Schneider as a represent9tive of ADF&G was .cussed by Schneider •.Trent.Reed.Lucid.Carson.and Wozniak.A concensus was reached that 11r.Schneider's participation in the core group was appropriate due to his technical participation on the $usitna Study Team as leader of the big game studies.All official responses from ADF&G as a part icipant in the review group will be handled by Mr. ~ent.who will consult with Mr.Schneider on technical matters.This arrangement was sat isfactory to the meet ing part ic ipants. There were no comments concerning information on the outline pertaining to the Role of the Core Group.the Role of the Review Group.or the Role of the Task Force Coord inator. Mr.Carson raised the issue of whether or not members of the review group should be required to prepare a written discussion of concerns, issues and pol icy statements.Mr.Carson felt that it was the responsibility of TES to prepare such material for review and comment by the review group.Following discussion of this issue,it was agreed that the Task Force Coordinator would draft a policy statement incorporat ing agency concerns and submit it to the review group for COmment.It was suggested that agency concerns could be better identified through personal interviews with representatives of each agency.TES and Acres will consider this approach. Mr.Wozniak questioned whether or not all appropriate agencies were included in the mitigation task force.The involvement of the U.S. Corps of Engineers.the Environmental Protection Agency,and the National Marine Fisheries Service were raised.TES and Acres will keep these agencies in mind as the task force proceeds.a1thou~h Mr.Reed indicated that the participation of these agencies may be either premature at this point in time.or be more appropriately included in the fisheries mitigation effort.Mr.Wozniak also raised the question of involvement by special interest groups.Mr.Reed and Dr.Lucid responded that the cpncerns of special interest groups were more appropriately coordinated throu~h the Power Authority's public participation program.TES will prepare a list of agencies and/or groups that may be considered for consultation in the future if pertinent issues concerning such groups develop. It was discussed,and generally agreed upon,that there are limitations to the level of detail of mitigation planning that can be performed within the Phase I time frame.Or.Lucid,Mr.Reed,and Mr.McMullen pointed out,nevertheless.that to comply with FERC regulations.the license application must represent a commitment on the part of the applicant and that identification of "options"may not be sufficient. - ~8 decided that individual review group members will address all .':espondence to the APA,with a copy being sent directly to Mr.Reed,i~~will back-channel a copy to Mr.Young at Acres.Mr.Wozniak ..rized the Task Force Coordinator (Mr.Reed)to represeht th~core ......up and correspond directly with members of the review group.Mr.' ~~requested written confirmation of this authorization from Mr. ~~9'Mr.Young indicated that Acres would provide the requested "'cumentat ion ..... Following discuss ion,it was agreed that Hr.Reed would reeval uate the schedule outlined on the handout.Mr.Carson requested that a meeting ~e held following preparation of a pol icy statement and review by the review group members. Mr.Stackhouse indicated that the USFWS had recently (within the past week)published a statement of mitigation policy in the Federal Register.Mr.Reed thanked Mr.Stackhouse for this information and indicated that the pol icy statement would be rev iewed at the earl iest possible date. Followin~discussion it was decided that the core group should first prepare ~mitigation policy,and following review,proceed with the preparation of a mitigation plan . .Stackhouse stated that cost effectivenes~of mitigation plans is an ,.oportant concern of the USFWS. The question was raised by Dr.lucid as to whether the applicant had any responsibility to enhance a resource,as opposed to avoidance of impacts or compensat ion.It was agreed that TES,in its mit i gat ion planning,would "identify enhancement opportunities"and stop there. The subject of compensation of impact on one species (e.g.moose)by enhancement of another (e.g.salmon)was mentioned.No agreement was reached on the validity of this concept. The question of whether or not the review group should have a chairman was raised.Mr.Reed expressed concern that some details may be lost if one person was responsible for compiling and possibly summarizing agency comments.Mr.Carson also advised against the appointment of a chairman at this time.For the present time,the idea of a review group chairman was dropped: Mr.Reed requested that a list be prepared with the name,mailing address,and phone number of all review group members.This list was completed and is aUached. The meeting was'adjourned at approximately 11:15 a.m. PARTICIPANT Edward Reed Joseph McM u 11 en Vincent Lucid Robert Krogseng Richard Taber Jay r'icKendr i ck Will iam Co 11 ins Brina Kes se 1 Steven McDonald Ph i 1 i p Gips an Kar 1 Schne i der Thomas Trent Kevin Young David Wozniak Bruce Bedard Alan Carson· Mike Scott Gary Stackhouse Bruce App ie SUSITNA WILDLIFE MITI~ATION TASK FORCE MEETING OF JANUARY 30,1981 ANCHORAGE,ALASKA LIST OF PARTICIPANTS REPRESENTING Terrestrial Environmental Specialists,Inc. Terrestrial Environmental Specialists,Inc. Terrestrial Environmental Special ists,Inc. Terrestrial Environmental Specialists,Inc. Terrestrial Environmental Specialists,Inc. University of Alaska Un ivers ity of Alaska Un i vers ity of Al ask a University of Alaska University of Alaska Alaska Department of Fish and Game Alaska Department of Fish and Game Acres American,Inc. A1ask a Power Author ity Alaska Power Authority Alaska Department of Natural Resources United States Bureau of Land Management United States Fish and Wildlife Service United States Fish and Wildlife Service --//'A ""'t"'"r-...r .-,.-I..r r ~I,/r;'~C l .'-=::::Lie :::::.;."::::'~.l.I[-=:~_~<,:=nv I ron m En ca. '-'?-~'".~c:;· [·.!..~~i7'-peCla is lS ~Inc . •~R.D.,BOX 365 P,",OENIX.N.Y.13'35 (J,sjS9s·,zza RECE1V1=O JUN 1 7 tSB1 ALASKA POWER MEMO AlITHORITY FjUSITNA Members of the Susitna Wild·i ife Mit igat ion Task Force Comments concerning the preliminary policy outline. FROM:Edward T.Reed.Task For~e Coordinator DATE:0une 16,1981;218.683 TO ~ c(RE:E ~ iii iX l-eno )UENCE NO. t:it,dI'Q J ILE P?7QQ, •II·>30 Please review the cbrninents made by other task force members and be _+~_I_--Iprepared to discuss possible adjustments to the policy statement.As noted in my memo of May 8,1981.the next meeting of the mitigation -1--,-----i·---t task force will be held at 9:00 a.m.on l~onday.June 29th,in the Acres Anchorage Office.Hopefully a final version of the pollcy statement can be agreed upon during that meeting and we can move forward with a discussion of how best to develop a mitigation plan bas'ed upon the policy statement. Enclosed please find another copy of the preliminary outline for the wildlife mitigation policy statement.I have inserted review comments that have been received todate.The comments have been placlid 1-"":::-..o;--''fJ-"'f immedi ately following the appropriate item.In the case of those comments that pertain to an entire section,they follow the last item of each section.In most cases,comments have been transcribed 1----1---;verbatum,although some comments had to be extracted from the ENS correspondence and minor editorial changes were made~ SNT ~--IDWL It should be noted that this was a detailed outline and 'some of the M-R-V~--~comments would have been unnecessary if a fleshed out text version was --H-R-C-available for review.It was impossible to totally explain all of the 1--.----,,---1 details and ramifications of each item within the context of an "l---L..L.:.......:L-J-..,.....,.-t 0 u t 1 i ne. WILDLIFE MITIGATION A STATEMENT OF POLICY PRELIMINARY OUTLINE 1 (-BACKGROUND 1.1 -The Need Included will be a general discussion of'the'value of the environment and why it is necessary to reduce or avoi~negative impacts while still permitting reasonable energy development. Comment USF&WS: This section should include a discussion of the need to adequately assess the environmental resources of the study area to determine the compatibility of the proposed project and to evaluate mitigation to adequately reduce or avoid negative .impacts to environmental resources,including fish and wildlife resources,so that no net loss of habitat value occurs. 1.2 -Legal Mandates The Federal Energy Regulatory Commission regulations,the Fish and Wildlife Coordination Act,and the National Environmental Policy Act will be discussed,as well as a consideration of the role of state and federal natural resource agencies whose task it is to protect and manage wildlife resources. 1.3 -Definition of Mitigation This will be the 5 part NEPA definition. 2 -GENERAL ?OLICIES TO BE CARRIED OUT BY THE APPLICANT 2.1 -Basic Intent of the Applicant (a)The goal of the applicant is to strive,within the bounds of feasibility and reasona.ble costs,to minimize the negative impacts of the Susitna Project and compensate for unavoidable losses of wildlife.and wildlife habitat. Comment USF&WS: The goal of the applicant should be to develop a plan to fully mitigate unavoidable impacts which would result from the construction and operation of the project with full compensation for unavoidable losses to fish and wildlife resources. (b)The success of the mitigation effort will be considered the difference between impacts without mitigation and impacts with mitigation.A "no net loss of habitat value"will serve as the benchmark for measuring both the success of the mitigation effort and project impacts. Comment USF&WS: Success of the mitigation effort should be assessed through comparison of habitat value of the study area with the project t including the mitigation plan,vs.withol,lt the project,over the prpject life.No net loss of habitat value,as determined by pre-and post-project studie~is the goal.Acceptable habitat evaluation procedures (such as the Fish and Wildlife Service's .Habitat Evaluation Procedures and Instream Flow Methodology) shaul d be used to accompl ish th is goaL t~cMullen: "No net loss of habitat val ue"looks good,but it must be dec;ded how to assess habitat value.Also,are with and/or without project scenarios going to be considered? Gipson: Good statement. {c}The applicant will provide assurances that the agreed upon mitigation plan will be a stipulated part of the construction and operation plans of the project and will be executed by either the applicant or any other organization charged with managing the project. Comment USF&WS: The mitigation plan should be developed by the applicant,in coordination with the state and federal resource agencies.The plan,as agreed upon by the coordinating agencies,should be submitted by the applicant to the Federal Energy Regulatory Commission {FERC}as a component of the application to be incorporated into the license. 2.2 -Input From Agencies and the Public (a)The applicant will provide opportunities for the review and evaluation of concerns and recommendations presented by the public as well as by federal and state agencies. Comment USF&WS: Additional review and evaluation of the project will be provided through formal agencies comments in response to state and/or federally administered licensing and permitting programs. (b)Agency comments and recommendations will be provided by those members of the Mit igat ion Task Force that represent agencies,while the concerns of the public and special interest groups will be coordinated through other means. """" COlTlTlent Gipson: You may wish to spell out how input will be obtained from the public and how to weight the recommendations from individuals, interest groupS,and governmental agencies. McMullen: One of the comments at the Steering Committee meeting was that the agency representatives in many instances cannot "officially" represent their agency. 2.3 -Avoidance and Reduction of Impacts (a)During the feasibility studies (prior to FERC license submittal)and the subsequent preparation of preliminary engineering specifications (following FERC license submittal),the applicant will take into consideration,and where practical {both from the standpoint of actual feasibility as well as cost},incorporate recommendations to avoid and/or reduce negative impacts on wildlife resources. Comment USF&WS: The project,including mitigation found to be acceptable to the state and federal resource agencies,should be evaluated in regard to reasonable cost;not with and without the mitigation plan.The total cost of mitigation then becomes part of the total project cost. (b)Also considered under this policy will be operation stipulations that can be implemented to reduce negative impacts on the wildlife resource.Recommendations for operation stipulations will be prov-ided to the design engineer during both the feasibility studies and the preliminary engineering phase as appropriate. Comment USF&WS: Construction and operating stipulations to reduce negative impacts to fish and wildlife resources should be evaluated during the feasibility studies.Stipulations found acceptable by the coordinating agencies should be incorporated into the mitigation plan submitted as part of the license application. 2;4 -Compensation for Unavoidable losses of Wildlife Resources (a)Where biologically feasible and cost effective management techniques are available,the applicant will institute management efforts to compensate for unavoidable impacts. Comment USF&WS: Compensation for unavoidable losses to fish aod wildlife resources should be in accordance with a plan developed by the applicant,in coordination with state and federal resource agencies.The plan,found acceptable to the coordinating agencies should be submitted to FERC for incorporation into the project license.The compensation plan,a component of the overall mitigation plan,should be the result of a habitat evaluation,utilizing a procedure judged acceptable to the state and federal agencies with primary responsibility for fish and wildlife resources. (b)Where possible,compensation will be of an in-kind nature. This applies to both wildlife species as well as habitats. Comment USF&WS: In-kind compensation where "possible";should be mutually Ideterminedbytheapplicant and the coordinating state and federal agencies,prior to licensing. I~ 2.5 _G:Dg;cphic :~~verage of the Wildlife Mitigation Policy (a)In rc;~"cd to both impact avoidance and compensation,the mitigat~:on policy will address all wildlife species uti1izinog the impoundment zone and other project related-, areas (~.g.,borrow sites),as well as the riparian zone downstrFam to Talkeetna. Comment USF&WS: Determination of the extent of impacts attributable to the project needs to be accomplished.Formulation of a mitigation plan cannot proceed until the extent of the impacts,both direct andi nd i rect, has been identified. McMullen: If key or target species are used to evaluate habitat values then this may requ-;:re reword i ng. Gipson: What treatment wi 11 be gi ven to access roads,power 1i ne ri ghts- of-way,and pcssible buffer zones around the impoundments? (b)Downstre~m from Talkeetna to Cook Inlet the primary mitigation effort will be directed towards any impacts that might occur in regard to rip"arian habitats. Comment USF&WS: The mitiga.tioo effort should be directed "at reducing impacts where they are identified,addressing all primary and secondary impact areas,for an project features. Taber: It seems probable that lQO%mHigation above the dam will not be feasible,so mitigation below the dam may be one of the next best choices.If a broad view of what "below the dam"consists of is maintained,then more mitigation options will be available than if the view is narrow. 2.6 -Establishment of Priorities (a)Although all wildlife species will be considered (including big game specie5,non-game species,and furbearers).it will be necessary to identify the "key"or "target"species and establish some order of priority in regard to the development of a mitigation plan. Comment McMull en: If key or target species are used to evaluate habitat values then this may require rewording. (b)In order to prepare a mitigation plan that can be successfully implemented while at the same time placing mitigation efforts in perspective.certain wildlife species and/or habitats will be given priority in mitigation planning based on:1)importance of the species/habitat both to Alaskan residents and the ecosystem;(2)availability of practical mitigation measures;(3)species with special status,such as threatened or endangered;(4)estimated costs required to execute mitigation measures.This list of· criteria is not organized in any priority order. Comment .Gi pson: Possibly something should be added to indicate that some ecological criteria will be used to establish priorities.in addi~ion to human values.For example,those species that contribute significantly to total energy flow through the system (small mammals and nesting birds)and/or those species that make up the bulk of animal biomass (again small mammals)should be considered important. McMull en: These criteri a could be easily expanded to be util i zed in the generation of relative value indicies. - USF&WS:(pertains to 2.6 in general) Since all wildlife species are to be considered,"key"species should be chosen so that they represent particular segments (guilds)of the community.Species which provide guild representation and are also con$idered "important"by the resource agencies and/or public should be given priority.Species which are federally listed ai threatened or endangered,or proposed for listing,must be handled separately in accordance with Section 7 of the Endangered Species Act.The practicality of the mitigation plan developed,in regard to the concerns of the applicant and coordinating agencies,would be demonstrated through its acceptabil ity to these agenci es. 2.7 -Impact-Related Versus Non-Impact-Related Lands (a)To the greatest extent possible,mitigation me~sures will be implemented on or immediately adjacent to the area where the impact takes place. (b)Where.this is not possible,priority will be given first to suitable areas as close as possible to the area of impact. (c)As a last resort,areas totally removed from the impact area will be considered for mitigation efforts. Corrnnent (pertains to 2.7 in general) USF&W5: Statements apply to both direct and indirect impacts. Schneider: In sections 2.7 and 2.8,you emphasize mitigation close to the impact area even to the point of enhancement of a different species rather than move to a more distant area.The problem is in definition of such terms as "reasonable proximity".Users of wi·l dl ife are fai rly mobile and tend to greatly favor one spec i es over another.This,combined with practical considerations,might make it difficult to stick with the policy I h:'.2n't given this a great deal of thought.but an alternate appr~~:h might be to direct mitigation measures at the animal pop~-~ion or subpopulation impacted when this is clearly feas -:=le. When :=he feasibility of this approach is in doubt,perhaps mitis~ion measures should be directed at user groups.A series of al~=rnate mitigation masures could be drawn'up and submitted for p1.~1bl ic review. The J:c'int is that the publ ic might agree with your pol icy,but .disag:--::e with your pl an when they see what it means in real ity. Why nc=recognize that the issue is complex and subjective from the st3rt? 2.8 -In-Ki~d Compensation Versus Availability of Areas Suitable For Miti s3tion (a)In the event that suitable areas for in-kind compensation for a particular species/habitat do not exist within reasonable proximity to the impact area,the first priority will be to compensate for such loss by enhancement of a different species and/or habitat that is close to the impact area. (b)If compensation by means of a different species proves impractical or unacceptable,in-kind compensation in areas totally removed frbm the impact area will be considered. Comment (pertains to 2.8 in general) Schneider: See comment under 2.7. 2.9 -Land Ownership fa}Interviews will be conducted with private owners as well as pertinent state and federal agencies to preliminarily identify land use policies or ownership that may act as constraints on mitigation efforts. (b)Where no land use constraints have been identified~the analysis of mitigation alternatives will proceed based on biological factors. (c)Following review by agencies and private landowners for· compatibility with land use po1icies~the mitigation plan will then be reassessed and adjusted as necessary in order to insure that proposed actions can be legally and practically executed.Where mitigation opportunities exist~the applicant will work closely with land management agencies to insure the successful implementation of the plan. 2.10 -Restoration of Disturbed Areas The applicant will consider various options (e.g.regrading .and revegetati6n~permitting natural invasion and succession~etc.) inthe reclamation of areas that will be disturbed by project activities such as borrow areas and construction camps. Comment USF&WS: Restoration of disturbed areas should be in accordance with a plan developed by the applicant,in coordination with the state and federal resource agencies.The plan,found acceptable to the coordinating agencies should be submitted to FERC for incorporation into the project license. r~cKendr i ck : I would emphasize that the revegetation,etc.,of borrow areas be coordinated with land use policies of owners.Also,considering such areas as prospective browse production sites may be feasible, if there is any soil available after excavation.They may be considered potential sites to compensate for browse losses in the impoundment areas. Heavy grass seeding will probably retard natural succession of browse species.We really need to examine some of the myriads of highway and seismic disturbances to see if we can identify successional sequences and bypasses and develop some reasonable scheme in habitat formation for this region. 2.11~Nuisance Animals In order to avoid altering the natural behavior of animals resident to the project area,rules designed to prevent,or reduce nuisance animal problems will be established.Procedures will also be formulated to relocate problem animals. Comment USF&WS: A plan,found acceptable to the coordination agencies,should be developed and submitted to FERC for incorporation into the project license. Schneider: Relocation is generally a poor policy as animals usually return or cause problems in other areas.Animals can be captured only under permits issues by the Commissioner of Fish and Game.He will set policy on this issues,not APA. Gipson: Other possibilities may be:1)strict garbage control and disposal,2)fencing of semi-permanent camps,3)education programs for workers to prevent feeding and harassing wild animals in order to reduce impacts and conflicts with people. - - 2.12 -Access (a)Since the potential impact of increased human access on wildlife is a major concern,measures will be considered and the most appropriate ones implemented to reduce impacts on wildl ife as a result of improved access. (b)This will include access policies during both the construction and operation phases of .the project. Comment (pertains to 2.12 in general) USF&WS: A plan,found acceptable to the coordinating agencies,should be developed and submitted to FERC for incorporation into the project license. \ 2:13 -Hunting {a}Acknowledging that sport hunting is an important component of the Alaskan 1 ifestyle and economy,it wi 11 be incoiporated as a major component in mitigation planning. (b)Hunting rules and/or recommendations to insure the safety of project personnel and the public will be considered. (c)For obvious reasons,any policy determination concerning hunting must be integrated with access policy and the appl icant wi 11 consider both access and hunqng pol icy in a coordinated manner. Comment (pertains to 2.13 in general) USF&WS: This section should be expanded to incTude other forms of wildlife recreation as well,e.g.,bird watching,photography.A plan, fOl-lnd acceptable to the coordinating agencies,should be developed and submitted to FERC for incorporation into the project license. Gipson: I would like for you to include trapping and fishing in this section if you feel they are appropriate for inclusion,. Schneider: Replace "sport hunting"with "hunting and trapping".Many Alaskans would interpret your wording to exclude subsistence hunting.This issue is both difficult to define and highly emotional.There is no need to raise it here.Obviously,we want to preserve all legal hunting and trapping options. Any hunting rules or policies other than those instituted by an employer on their employees are the responsibility of the Board of Game.APA can make recommendations as can any group or individual,but it is up to the Board of Game to examine all factors and set regulations for dealing with pro~lems. Reed: It may be that this section is not appropriate at all for inclusion with a wildlife mitigation policy effort and may be better suited for 'prime consideration under the recreation planning portion of the $usitna study effort;although coordination between recreation planners and the wildlife mitigation group is certainly necessary. 2.14 -Responsibility For Implementation of the Mitigation Plan (a)Prior to the initiation of construction an agreement will be reached for determining responsibility for implementation of the mitigation plan. Comment USF&WS: Responsibility for implementation of the mitigation plan rests with the applicant.Any agreements entered into by the applicant for the delegation of direct implementation authority for the mitigation plan would need to include stipulations to prevent deviation from the accepted plan. - Reed: Due to wording there is some confusion between 2.14 (a)and 2.1 (c).The intent of the wording in 2.1 (c)was to indicate that the applicant (APA)was ultimately responsible for seeing that the mitigation plan is executed as agreed upon.The purpose of 2.14 (e)was not to indicate that any organization other than the appl icant would have ultimate responsibil ity,but to indicate that an agreement would have to be reathedas to exactly who (ADF&G, USF&WS,TES,etc.Ywould actually execute the plan.A rewording, or further explanation is needed to prevent;;a misunderstanding between these two items. (b)Realizing that a mitigation monitoring team will be necessary to insure the proper and successful execution of the mitigation plan,part of the plan will detail the structure and responsibilities of such a monitoring body. Comment USF&WS: The mitigation monitoring team should include representatives of the applicant,FERC,and the state and federal agencies with designated responsibility for fish and wildlife resources.The financing,composition,and plan of study should be agreed to by the prospective participants during the formulation of the mitigation plan as a component of the mitigation plan to be submitted to FERC for incorporation into the license. 2.15 -Modification of the Mitigation Plan (a)As part of the mitigation plan a monitoring program will be established,the purpose of which will be to monitor wildlife populations during the construction and operation of the project in order to determine the effectiveness of the plan as well as to identify problems that were not anticipated during the initial preparation of the plan. Comment USF&WS: See corrments above {2.14.b}. Gipson: This section,2.15 (a)is good. (b)The mitigation plan will be sufficiently flexible so that if adequate data secured during the monitoring of wildlife populations indicate that the mitigation effort should be modified,the mitigation plan can be adjusted accordingly; this may involve an increased effort in some areas where the original plan has proven ineffective,as well as a reduction in some cases where impacts failed to materialize as predicted. Comment USF&WS: Any modification to the mitigation plan should be coordinated with,and agreeable to,the state and federal agencies with designated responsibility for fish and wildlife resources. General Comments McKendri ck: Bill Collins and I both received and read the Preliminary Outline. Generally,it appears acceptable and comprehensive. Wozniak: We have no comments relative to the version of the Mitigation Policy outline transmitted to us by Ed Reed's memo of May 8~1981.{Note: The APA did review an earlier version and provided suggestions and comments that were incorporated into this review version}. Gipson: This is a well written outline.You .may want a section treating use of 4-wheel drive vehicles and snow machines. USF&WS: We appreciate the opportun;tyto 'rev;ew;theprel'~~i nary out 1;ne "Wildl He Mitigation:A Statement of Pol fey".We have done so in light of the Fish and Wildlife Service's Mitigation Policy (copy attached)and have provided comments which are consistent with that policy. :rerrestrial nvironmental Specialists,inc. II.D.t BOX :18.PHOENIX.N.Y.1313.•(3""'''-722' MEMO RECEIVED JUt 2 7 i93\r TO:Members of the Susjtna Wildlife Mitigation Task Force FROM:Edward T.Reed,Task Force Coordinator DATE:July 24,1981;218.730 RE:Meeting notes Enclosed please find a copy of the notes of the June 29,1981 meeting of the wildlife mitigation task force.I have compiled these notes based on my interpretation of theconunents made during the meeting.If you feel that I missed any major items or misunderstood certain statements please let me know and I will prepare a revised version of the notes.I am now moving forward with the preparation of a draft policy statement an~~-SK-A-P-O~-VE-R~ development of a decision making methodology.You will be receivi 9 AUTHOIIITY copies of these as they are completed.SUS/TNA Fll~.P5;:;O 1 SEQU£NC~~l • I. . I ' z;;E !n'..J1OlreiiioJ': i=2 t;1'~!~~0 ;:'_iDCWj~ t..~......... -1-::;-1..-, ,'J!Ci\-,I ,.I 1--=;---:.-.J 10,-;''.'It-4:··,.---JYu I UN£Q~~.~-:J'~';i ;c-,- -~-~~iJ-=l •E~:~l I 8 -1 ~:::l--i.--I-.Mq~/.i--:,.-1--,-_1 ,Hf!C·i I -C~g1_::::L -<.-'-.-U1/1IrI~·LJ ..:/-i!t·/~('j f'[]-j- i I :--, - SUSITNA WILDLIFE MITIGATION TASK FORCE NOTES OF MEET I NG ' June 29,1981 Anchorage,Alaska Camp n ed by:Edward T.Reed Wildl ife Ecology Group leader Terrestrial Environmental ·.Special ists,Inc. The meeting was commenced at 9:00 a.m.A list of participants is attached. Mr.Reed gave a brief introduction and description of ~at had taken place since the last meeting.He then asked if the participants would 1ike to make any general comments concerning the pol icy outl ioe prior to beginning a detai 1ed discussion of the items contained within the outline. Mr.Wozniak requested that the purpose of the meeting be to move towards a final izedstatement as the next product. Mr.Trent stated that although the policy addressed federal regulations, there are state regul ations concerning mitigation in draft form,and the mitigation effort should stand prepared to include the intent.and approach presented in those state regulations.He also indicated that the state regulations would use the five basic forms of mitigation as defined by NEPA,but will go further in stressing the priority of the forms.He indicated that the new regulations would be incorporated under Title 16 1 aw.Mr.Trent also suggested that a matrix type approach be developed to be used in reviewing the various forms of mitigation that might be used on the Susitna Project. -2- Mr.Trent said that for the purpose of developing mitigation policy it would be advisable to involve the personnel responsible for the fisheries mitigation effort.Mr.Schneider agreed that the policy statements for both fish and wildlife should be basically the same.Mr. Wozniak also indicated that this would be preferable.Mr.Wozniak then. requested that Mr.Reed take the appropriate steps to obtain the involvement of the fisheries group.'Mr.Reed agreed to contact the appropriate fisheries personnel and request that they accelerate the "establishment of a fisheries mitigation task force and be provided with information pertaining to the policy statement currently being prepared by the wildlife task force. ~ A discussion took place concerning the level of mitigation planning that would be available for inclusion with the FERC license application versus what will have to follow during Phase II.Mr.Wozniak warned that Phase II should not serve as a convenient excuse for not having critical portions of the application prepared for the projected submittal date.Mr.Carson indicated that a corrunitment to the process that would be used throughout the mitigation effort should be an important item for the application.Since the discussion indicated that at a minimum,it will be possible to have prepared a policy statement, In approach to mitigation,and an outline of the ol~n~Mr.Reed asked representatives of the U.S.Fish and Wildlife Service if that level of 2ffort would satisfy their review needs as stipulated under the Fish and Wildlife Coordination Act.Mr.Stackhouse replied that in the absence of a complete,detailed mitigation plan,they (USF&WS)would not be able to make a final recommendation. Mr.Schneider suggested that the next step should be the development of a process,or methodology,to be used in making mitigation decisions. This suggestion was received favorably by the other participants. In reviewing the meeting to this point,Mr.Reed and Mr.Wozniak agreed that the next steps should be to expand the outline to a draft policy statement,prepare a decision making methodology,and develop an outline of the plan. - -3- At this point it was agreed to review the policy outline,item by item, commenting on the information anddeterminirigwhich items are appropriate for a policy statement and which items might be more suitable for inclusion in other sections The following notes are organized by items co"rresponding--'iO'··the outlirte. Ll -Mr.Trent indicated that there is a need to study the resources and for the APA to .commit to mitigation.He suggested substituting "mitigate"for Ilreduceor'avoid.II 1.2 -Mr.Trent reiterated the need to take into consideration state ~licies and regulations.Mr.Carson suggested consideration of the DNR Instream Flow Bill and the Coasta.1 Zone Management Group. 1.3 -Mr.Trent suggested that the remaining items discuss mitigation collectively rather than identifying only certain forms of mitigation. 2.1 (a)-Mr.Trent said that a compromise position is needed somewhere between the phrases "agreeable to all agencies ll and "feasible and reasonable.11 Mr.Carson sugQested removinC!th.=a phrase lIfeasible and----- reasonable.11 Mr..Trent suggested using a phrase such as,"to strive to mitigate the negative impacts.II Mr.Schneider mentioned that reality should be kept in mind when defining the intent.· (b)-Mr.Wozniak indicated that there was ~o problem with this item but felt that it should be removed from the pol icy statement and incorporated at a diff~rent point in the mitigation plan~Mr.Carson agreed. (c)-Mr.Wozniak indicated that this item would be part of the license and indicated that an associated goal would b~to reach an agreement between the resource agencies and the appl icant. -4- 2.2 -Mr.Carson discussed the roles of the A?A and the resource agencies as they pertain to public input.The possibility of agency personnel being available at public workshops to present the position of their respective agencies was discussed.MI"'.Wozniak liked the idea of agency personnel being available during public meetings. 2.3 (a')-Mr.Carson reiterated a previously expressed concern about the wording of this'item.Mr.Wozniak remarked that the agencies and the "APA are polarized in regard to this item.Following discussion it was agreed that what is needed is a rewording that will provide the agencies with stronger assurances,while at the same time not totally committing the APA. (b)-It was agreed that this item is too specific for a policy statement and might be more appropriately incorporated into a "methodology"section. 2.4 -Mr.Trent suggested that the forms of mitigation be combined under a more general category.It was agreed that this section should be removed from the policy statement and placed elsewhere. 2.5 -Mr.Stackhouse expressed interest in how the coverage would be defined.It was agreed that this section may also be more appropriately covered in a subsequent portion of the mitigation ~lan. 2.6 thru 2.13 -It was agreed that these sections would also be more appropriately addressed in other portions of the mit'igation plan. 2.14 -Mr.Wozniak indicated that the APA is in agreement with this item and has no problem with the wording.Mr.Carson felt that 2.14(b) should be reworded to include the word "funding"and suggested the following wording,"••.part of the plan will detail the structure, fund~ng,and responsibilities .••"Mr.WOzniak felt that this may be a problem at this time and indicated that funding arrangements are an itemthat would have to be negotiated at a later date.MI"'.Wozniak also felt that is was a good idea for the agencies to provide a commitment to cooperate in this effort. - -5- 2.15 -Mr.~ozniak stated that the APA is in agreement with this item and has no problem with the wording. Mr.Carson expressed the opinion that the mitigation effort was going well and he was pleased with the approach being taken so far'. The meeting was adjourned at approximately 11:30 a.m. PARTICIPANT Edward Reed Leonard Corin Gary Stackhouse ~David Wozniak Brina Kessel Thomas Trent Joseph McMull en Karl Schneider Phil iP Gi pson Alan Carson Robert Krogseng Jay McKendrick SUSITNA WILDLIFE MITIGATION TASK FORCE MEETING OF JUNE 29.1981 ANCHORAGE.ALASKA LIST OF PARTICIPANTS REPRESENTING Terrestrial Environmental Specialists,Inc. United States Fish and Wildlife Service United States Fish and Wildlife Service Alaska Power Authority TES/University,of Alaska Alas0a Department of Fish and Game Terrestrial Environmental Specialists,Inc. Alaska Department of Fish and Game TES/University of Alaska Alaska Department of Natural Resources Terrestrial Environmental Specialists,Inc. TES/University of Alaska October 6,1981 Mr.Eric P.Yould Executive Director Alaska Power Authority 3334 West 5th Avenue Anchorage,Alaska 99501 Dear Mr,.Yould: \ UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmo.spheric Administration Nc.:iD~'-.::'~..'i::,:,:·:ne F'i!3.he~ies,Service F.O.E~=12eS Ju.nec:.u~.4 Z.asr~998 C2 RECEJVEO OCT 1 5 1981 ~ I Involvement of this agency with efforts by others to explore the . potential for hydroelectric development on the Susitna River dates back to 1973.In 1974,we had contracted Environaid for a study titled "A Hydrologic Reconnaissance of the Susitna River Below De;,vil's Canyon", and more recently we have been a participant on theSusitna Steering Cominittee. He appreciate the opportunity presented in your 1etter of September 25,1981 to extend our participation by becoming a member on the SusitnaFisheries t'1itigation Task Force,Review Committee.r have directed Brad Smith of our Environmental Assessment Division (EAD),Anchorage Field Office to- represent National Marine Fisheries SerVice (~MFS)on this important com- mittee.·Mr~Smith \"ill fully participate on the Review Committee and be responsible for drafting the recommended NNFS 1 position. Please continue to send official correspondence through our Regional Office.Delays in NMFS response time associated w~th our routing of your materials to and from the Anchorage EAD Field Office could be reduced if you would provide a courtesy copy of correspondence dir- ectly to Mr.Smith. Should you have further questions regarding Mr.Smith's involvement, please contact Ron Morris,the supervisor of the Anchorage EAD Field Office: Bradley K.Smith and Ronald J.Morris National Marine Fisheries Service Federal Building &U.S.Court House 701 C Street,Box 43 Anchorage,Alaska 99513 Phone:(907)271-5006 Si ncere ly, \Jh0~V1.C~~1ft'\·.(1Robert W.tkVey Director,Alaska Region RECEIVED gCi 11981 ALASKA POWER AUTHORITY 334 WEST 5th AVENUE·ANCHORAGE.ALASKA 99501 Phone:(907)277·7641 (907)277·0851 (907)276.QOO 1 September 25,1981 Mr.Robert McVey Director,Alaska Region Alaska Marine Fisheries Service P.O.Box 1668 Juneau,Alaska 99802 Dear Mr.McVey: Integral to our study of the potential effects of hydroelectric development of the Upper S~sitna River Basin is the formulation of fisheries mitigation plans.To that goal,a Fisheries Mitigation Task Force,in two parts,is being formed.One part will be a core group of the principal investigators.Their task will be to identify and address impacts,and develop appropriate mitigation plans.A second group will act as a review committee commenting on the efforts of the core group. SEQUENC~NCr.//'..r~/'7 ;:-...,.-' ! --------(----1---- -1·-i -'!-'-".- ../>-_.~,il'"-'... cc~John Lawrence Jim Gill We welcome your participation in this key planning area,and we hope to hear from you soon with the names and telephone numbers of your designated representation. Sincerely, ~cp~~u~J$ Executive Director You are invited to be a member of the Review Committee.If you agree,your role would be to work in concert with other concerned agencies to assess the adequacy of the impact predicitons and associated mitigati~------_ Planning.In addition to reaping the benefits of your expertise,your AUSKA POW~RAUTHO.',T tparticipationwouldalsofulfillkeyconsultationrequirementsoutlinedSUSITNA in the Federal Energy Regulatory CommiSsion (FERC)regulations and in the provision of the Fish and Wildlife Coordination Act.FILE P5/00 A similar structure was established early this year for wildlife mitigation.An early objective will be to reorganize into one common review committee for mitigation,overviewing separate core groups for fisheries and wildlife.You might consider this when you appoint your organizational representative. -REPLV TO ATTENTION Of, DEPARTMENT OF THE ARMY ALASKA DISTRICT.CORPS OF ENGINEERS P.O.BOX 7002 ANCHORAGE.ALASKA 99510 .'".. -. ..... NPAEN-PL-EN Mr.EricP.Yould Executive Director Alaska Power Authority 334 West 5th Avenue Anchorage.Alaska 99501 Dear Mr -1Ou 1d: OC1 20 \981 13 OCT 1981 .... ..... ..... i -I ,-- This is in response to your letter of 25 September 1981 concerning Corps of Engineers participation in the Upper Susitna River Basin Fisheries Mitigation Review Committee • Unfortunately.the continued funding and manpower constraints under which we must operate make it necessary for me to de«:l ine your invitat ion.However,we will provide the reviews required for the issuance of permits ,under our regulatory program. If I can be of further assistance.please contact me directly.If further details are desired by your staff,contact can be made with Mr.Harlan Moore, Chief,Engineering Division at 752-5135 • LEE R.NUNN Colonel,Corps of Engineers District Engineer .._---------------------------------- JA r s.HAMMOND,GOVERNOR I SUBPORT BUILDING JUNEAU.ALASKA 99801 DEPART,n::\:T OF FISn :\.'()G:\..UE OFFICE OF THE COMMISSIONER October 23,1981 Mr.Eric P.Yould Alaska Power Authority 334 West 5th Avenue Anchorage,Alaska 99501 Dear Mr.Yould: ~ Thank you for your invitation to place a member of my staff on the committee being established to review mitigatory recommendations for the Susitna Hydroelectric project.I have designated Mr.Carl Yanagawa, Regional Supervisor for the Habitat Division,to sit as our represent- ative on the review committee. I anticipate that Mr.Yanagawa will work closely with the other members of the committee,and with Tom Trent and Karl Schneider,to develop sound policy recommendations for Su-Hydro. Nr.Yanagawa's office is in the Fish and Game building at 333 Raspberry Road and he can be reached at 267-2138. Sincerely, Q 1 Ronald O.Skoog --+61.Commissioner J.-(907)465-4100 .,·Kl1LH u.s. REPLY TO IS·443ATTNOF:M '.. : V I.• EN V IR0 NM EN TAL P ROT EC T ION AGE N C Y REGION X 12~O SIXTH AVENUE SEATTLE,WASHINGTON 98101 ilECEIVEO Ge!~_. Al.ASK/\pnwr:r>_~.~en Afld/"'/'7~"'I,)' Eric P.Yould~Executive Director Alaska Power Authority 534 West 5th Avenue Anchorage,Alaska 99501 DearMr~~ RECEIVED OCT 3 ()1531 AU\SKA POWER AUTHORITY - .- ,.... - The Environmental Protection Agency (EPA)accepts your invitation to participate on the Review Committee for the Fisheries Mitigation Task Force on the hydroelectric development of the Upper Susitna River Basin. -EPA generally relies on the state and Federal fish and wildlife agencies for the technical input and evaluation on such task forces.However,I feel that we may be able to provide as a member of the Review Committee • a different perspective which may help your efforts.Because of our limited resources both in staff and travel money.our participation will have to be somewhat limited. I have designated Ms.Judi Schwarz as our formal contact for the activi- ties of this Review Conmittee.Ms.Schwarz is in the Environmental Evaluation Branch in our Seattle Office and has had primary contact with the Susitna project through our EIS review responsibil ities.She can be reached at (206)442-1285.I have also asked Jim Sweeney~Director of our Alaska Operations Office to provide support in this effort because of his proximity and knowledge of the unique Alaska conditions.His tele- phone number in Anchorage is (90l)271-5083. We look forward to actively participating on this Review Corrrnittee.Any infonnation you can send us on the act ivifies of the wildl ife miti gat ion task force would be appreciated. Thank you for giving us the opportunity to become actively involved in this important development. cc:Jim S\'Jeeney nEIDAnT~IENT Ot'N.'\TURi\J.lu';SUUnCt;s OFFICE OF THE COMMISSIONER JAr s.HAMMOND,GOVERNOR POUCHM JUNEAU.ALASKA 99811 PHONE:(907)465-2400 December 1,1981 Mr.Eric Yould Executive Director Alaska Power Authority 334 West 5th Avenue Anchorage,AK 99501 Dear Eric: 10-J9I..H This letter is in response to your September 28,1981 letter offering an opportunity for DNR participation on the mitigation review committee for the proposed Susitna Hydroelectric Project, Al Carson of the Division of Research and Development will be our representative for the committee.He can be reached by phone at 276-2653.' Thanks for providing us with the opportunity to participate in this important endeavor. Sincerely, ~z Commissioner cc:·Reed Stoops .-.--_.-._~_.~~~_~.•...-.-._~..__.._---_--------------------- -ALASliA POlfER AUTHORITY 334 WEST 5th AVENUE·ANCHORAGE,ALASKA 99501 RECEIVED DEC 14 1981 December 9,1981 Phone:(907)277-764 (907)276·0001 .-ACkt~I\lftCJUIiIUt InliultrUKAIID Mr.Keith Schreiner Regional Director,Region 7 U.S.Fish &Wildlife Service 1011 E.Tudor Road Anchorage,Alaska 99503 Dear Mr.Schreiner: A member of your staff advises me you did not receive my letter of September 25,1981,inviting your participation to the Susitna Hydroelectric Project mitigation Review Group.Let me hasten to repeat the invitation. Integral to our study of the potential effects of hydroelectric development of the Upper Susitna River Basin is the formulation of fisheries mitigation plans.To that goal,a Fisheries Mitigation Task Force,in two parts,is being formed.One part will be a core group of the principal investigators.Their task will be to identify and address impacts,and develop appropriate mitigation plans. A Second group will act as a review committee commenting on the efforts of the core group. You are invited to be a member of the Revi.ew Committee. If you agree,your role would be to work in concert with other concerned agencies to assess the adequacy of the impact predictions and associated mitigative planning.In addition to reaping the benefits of your expertise,your participation would also fulfill key consultation requirements outlined in the Federal Energy Regulatory Commission (FERC)regulations and in the provisions of the Fish and Wildlife Coordination Act. A similar structure was established early this year for wildlife mitigation.An early objective will be to reorganize into one common review committee for mitigation, overviewing separate core groups for fisheries and wiJdlife. You might consider this when you appoint your organizational representative. Mr.Ernest W.Mueller Commissioner Alaska Department of Environmental Juneau,Alaska 99801 Uear Mr.Mueller: November 19,1981 P5700.11.92 Conservation Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy As you know,Acres American,Incorporated is under contract to the Alaska Po~Authority (APA)to conduct a feasibility study and prepare a Federal Energy Regulatory Commission (FERC)license application for the Susitna Hydroelectric Project.The scheduled date for submission of the application is in June of 1982 • .Federal law and FERC regulations require that the reports supporting the FERC application be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.This coor- dination must be documented in the license application. A great oeal of coordination has taken place at agency staff levels by dir- ect participation in studies or by participation in committees and task groups.This input,however,has been primarily by staff and may not nec- essarily reflect the views of the agency.For this reason,we are conduct- ing a parallel formal coordination process,by requesting agency comments on key study outputs.The plan of study was the first document coordinated in this manner.Over the next year.there will be several more.This par- allel process will affect the other coordination activities of the study. At this time.we request that the Alaska Department of Environmental Conservation review the attached Fish and Wildlife Mitigation Policy,which has been developed by APA,the resource agencies and Terrestrial Environmental Specialists. ACRES AMERICAN INCORPORATED '':._".,~~:I':;E-;;~C:E:rs Fish and Wildlife Mitigation Policy Page 2 November 19.1981 ""'" Your prompt attention to this matter will enable us to continue planning the best possible development for all interests.A response within thirty days of receipts would be greatly appreciated.Please send a copy of your comments to me and to: Mr.Eric Yould.Executive Director Alaska Power Authority 333 West 4th Avenue Anchorage,Alaska 99501 Very truly yours, JOLI MMG:j gk Ene. .Jk-4..-J>\/..,4(~I..M ~ John o.Lawrence Proj ect Man ager ,... cc:Bob Martin (letter only) ACRES AMERICAN INCORPORATED Mr.Robert McVey Oirector~Alaska Region National Marine Fisheries NOAA P.O.Box 1668 Juneau~Alaska 99802 Dear Mr.McVey: Service November 19 t 19~1 P5700.11.91 Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy As you know,Acres American,Incorporated is under contract to the Alaska Power Authority (APA)to conduct a feasibility study and prepare a Federal Energy Regulatory Commission (FERC)license application for the Susitna Hydroelectric Project.The scheduled date for submission of the application is in June of 1982. Federal law and FERC regulations require that the reports supporting the FERC appl ication be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.This coor- dination must be documented in the license application. A great deal of coordination has taken place at agency staff levels by dir- ect participation in studies or by participation in committees and task groups.This input,however,has been primarily by staff and may not nec- essarily reflect the views of the agency.For this reason,we are conduct- ing a parallel formal coordination process t by requesting agency comments on key study outputs.The plan of study was the first document coordinated in this manner.Over the next year~there will be several more.This par- allel process will affect the other coordination activities of the study. At this time,we request that the National Marine Fisheries Service review the attached Fish and Wildlife Mitigation PolicYt which has been developed by APA t the resource agencies and Terrestrial Environmental Specialists. ACRES AMER1CAN INCORPORATED Fish and Wildlife Mitigation Policy Page 2 November 19.1981 Your prompt attention to this matter will enable us to continue planning the best possible development for all interests.A response within thirty days of receipts would be greatly appreciated.Please send a copy of your comments to me and to: Mr.Eric Yould.Executive Director Alaska Power Authority 333 West 4th Avenue Anchorage,Alaska 99501 Very truly yours. ,~ "'" ,~ ..... ..lDL/Mr-tG:j gk Enc. cc:Ron Morri 5 (letter only) ACRES AMERICAN INCORPORATED ~1>.L-.,~/A-~ John D.Lawrence Project Manager November 19,1981 P5700 •.11.91 Mr.Keith Schreiner Regional Director,Region 7 U.S.Fish and Wildlife Service 1011 E.Tudor Road Anchorage,Alaska 99503 Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy Dear Mr.Schreiner: As ~know,Acres American,Incorporated is under contract to the Alaska Power Authority (APA)to conduct a feasibil ity study and prepare a Federal Energy Regulatory Commission (FERC)license application for the Susitna Hydroelectric Project.The scheduled date for submission of the application is in June of 1982. Federal law and FERC regulations require that the reports supporting the FEI<C application be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.This coor- dination must be documented in the license application. A great deal qf coordination has taken place at agency staff levels by dir- ect participation in stUdies or by participation in committees and task groups.This input,however,has been primarily by staff and may not nec- essarily reflect the views of the agency.For this reason,we are conduct- ing a parallel formal coordination process,by requesting agency comments on key study outputs.The pl an of study was the first document coordi nated in this manner.Over the next year.there will be several more.This par- allel process will affect the other coordination activities of the study. At this time.we request that the U.S.Fish and wildlife Service review the attached Fish and Wildlife Mitigation Policy,which has been developed by APA.the resource agencies and Terrestrial Environmental Specialists. ACRES AMERICAN INCORPORATED fish and Wildlife Mitigation Policy Page 2 November 19,1981 Your prompt attention to this matter will enable us to continue planning the best possible development for all interests.A response within thirty .days of receipts would be greatly appreci ated.Please send a copy of your comments to me and to: Mr.Eric Yould,Executive Director Alaska Power Authority 333 West 4th Avenue· Anchorage,Alaska 99501 Very truly yours, -- .JDl!MMG:j gk Ene •. ACRES AMERICAN INCORPORATED John D.lawrence Project Manager [f,T ',~l,~~'1.:.,~ .l U~-....... r"r.Ronald Skoog Corrmissioner State of Alaska Department Juneau,Alaska 99801 Dear Mr.Skoog: November 19,1981 P5700.11.92 of Fi sh and Game Susitna Hydroelectric Project fish and Wildlife Mitigation Policy As you know,Acres American,Incorporated is under contract to the Alaska Power Authority (APA)to conduct a feasibility study and prepare a Federal Energy Regulatory Commission (FERC)license application for the Susitna Hydroelectric Project.The scheduled date for submission of the application is in June of 1982. Federal law and FERC regulations require that the reports supporting the FERC appl ication be prepared in consultation with Federal and State agen- cies having managerial authority over certain project aspects.This coor- dination must be documented in the license application. A great deal of coordination has t •..::en pl ace at agency staff levels by dir- ect participation in studies or by participation i,n committees and task groups.This input,however,has been primarily by staff and may not nec- essarily reflect the views of the agency.'For this reason,we are conduct- ing a parallel formal coordination process,by requesting agency comments on key study outputs.The plan of study was the first document coordinated in this manner.Over the next year,there will be several more.This par- allel process will affect the other coordination activities of the study. At this time,we request that the State of Alaska Department of Fish and Game review the attached Fish and Wildlife Mitigation Policy,which has been developed by APA,the resource agencies and Terrestrial Environmental Speci al i sts. ACRES AMERICAN INCORPORATED (.:.,.,,,:":'.:~r ...·--~........:......._:..~...r;"::-C l ;.:;....'~:::.'::G~"";~:'-'c,c - - Fish and Wildlife Mitigation Policy Page 2 . November 19,1981 Your prompt attention to this matter will enable us to continue planning the best possible development for all interests.A response within thirty days of receipts would be greatly appreciated.Please send a copy of your comments to me and to: Mr.Eric Yould.Executive Director Alaska Power Authority 333 West 4th Avenue Anchorage.Alaska 99501 Very truly yours. ~.:D.l-..~!.,A1& ,~ JDL/MMG:jgk Enc. cc:Tom Trent (letter only) ACRES AMERICAN INCORPORATED John D.Lawrence Project Manager DEP.·\RT :".::\T 0.'.'ISIt :\,..G.\11.: OFFICE OF THE COMMISSIONER December 30 s 1981 Mr.John D.Lawrence Project Manager Acres Americans Inc. The Liberty Bank Buildings Main at Court Buffalo s New York 14202 Dear Mr.Lawrence: The Alaska Department of Fish and Game has reviewed the IIS us itna Hydroelectric Project Fish and Wildlife Mitigation Policyll dated November 1981 and has several comments to offer.The Department is drafting a mitigation policy approval we -,-in:gnd to use for all hydroelectric projects throughout the State.We A~SK~poa~prel~iate your effort but feel our parallel effort is the alternative we select !AUTHC'::ltb ta e.In the interims however s I have provided comments to your document SUS~~,~ftat-,an be used to improve your policy as drafted. FILE P57:lQ I .co ~5i~i!Fic Comments .----.\"er:Q\j~["r::=rJO ;tt.:'"~.1.;:V~~~Section 1 -Introduction \;DI~!'!(i i ~,~n this section which reads as follows s we recommend inclusion of the ':!(.,i ;"::,:underlined phrase.b t]'.i!'-;I(~I~;:~,_.~;_;._;~j'A mandate of the Alaska Power Authority (APA)charter is to develop -i-~'_"'::~upplies of electrical energy to meet the present and future needs of the 1 -':~:_!J_J;tate of Alaska.APA also recognizes the value of our natural resources ,.--.~.~nd accepts the responsibility of insuring that the development of any new -1---0--projects is ~s compatible a~possible with the fish and wildlife resources ~-~,'-~.h Ud he habltat that sustalns them)of the State and that the overall _1_J'~fJI cts of any such projects wi1l be beneficial to the State as a whole. ~I!-';.-.!In this regard APA has prepared a Fisheries and Wildlife ~1itigation Policy -_."for the Susitna Hydroelectric Project as contained herein.1I -I-i"~'"Comment:The primary goal of mitigation is to avoids mlnlmlZe.rectify, -i-;'!,-;---ireduce or compensate for impacts on fish and wildlife habitats. -1-''I -1--2.--u Section 2 -Legal f1andates,.=!':~In thi~section \.'ihich reads as fol1ows,we suggest inclusion of the_I=:-:~'>~'--t:J~~lned phrase: _.i=L.._:'(~r.J_!__--Ii .J .....r FILE \ Mr.John D.Lawrence -2-December 30,1981 - "There are numerous state arid federal laws and regulations that specifically require mitigation planning.The mitigation policy and plans contained within this document are designed to comply with the collective and specific intent of these legal mandates.Following are the major laws or regulations that require the consideration (and eventual implementation) of mitigation efforts." Comment:Consideration of mitigation is not an end in itself,the implementation of mitigation is the eventual goal and obligation which the APA must meet under the terms of State and Federal law and regulation. 3.Section 2 -Protection of Fish and Game In the first paragraph,first sentence,that reads as follows,we suggest the underlined phrase be inserted: The Alaska state laws pertaining to the disturbance of streams important to anadromous fish address the need to reduce (or prevent)impacts on fish and game that may result from such action. Comment:Avoidance as well as minimization of impacts is also of concern to ADF&G. 4. 5. Section 2 -Federal Energy Regulatory Commission,2nd paragraph We suggest the paragraph include a statement which indicates measures of mitigation as well as facilities for mitigation be described~To describe only facilities suggests that only engineering solutions for mitigation are considered.It will be necessary to describe any measures for mitigation that may involve,for example,in-kind replacement of habitat or avoidance of impact alternatives. Comment:.•For this statement to be an accurate portrayal of FERC regulation,this addition is suggested. Section -3.3 Implementation of the Mitigation Plan In the first paragraph of this section,it is stated that,"Prior to implementing the plan;an agreement will be reached as to the most efficient manner in which to execute the plan." Comment:It should be stated with 'dhom this agreement is to be reached. Perhaps suggestions can be \'JOrked out vdt"the Su Hydro Steering COr.lmittee. Also it is stated in the second paragraph of this section,"Realizing that a mitigation monitoring team will be necessary to insure the proper and ~uccessful execution of the mitigation plan,part of the plan will detail the structure and respons ibn iti es of such a monitori ng body./I Comment:APA should be aware that this monitoring body or its functions will not supersede individual.agency mandates. Mr.John D.Lawrence -3-December 30.1981 6.Section 3.4 Modification of the Mitigation Plan In the second paragraph of this section which reads as follows.we suggest the insertion of the underlined phrases: liThe mitigation plan will be sufficiently flexible so that if data secured during the monitoring of fish and wildlife populations and habitats indicate that the mitigation effort should be modified.the mitigation plan can be adjusted accordingly.This may involve an increased effort where r impacts failed to materialize as predicted.'Any'modifications to the mitigation plan proposed by the monitoring team will not be implemented without consultation (and approval of)appropriate state and federal agencies and approval of APA.The need for continuing this monitoring will be reviewed periodically.The monitoring program will be terminated when the need for further mitigation is considered unnecessary.II Comment:APA approval alone does not supersede the mandates of state and federal agencies to assure that mitigation to be performed is prudent and feasible and in concert with what is known about project impacts. 7.Section 4 -Approach to Developing the Fish and Wildlife Plans The third paragraph of this section reads as follows: IIFollowing the identification of impact issues.the Core Group will agree upon a logical order of priority for addressing the impact issues.This will include ranking resources in order of their importance.The ranking will take into consideration a variety of factors such as ecological value. consumptive value.and nonconsumptive value.Other factors may be considered in the ranking if deemed necessary.The impact issues will also be considered in regard to the confidence associated with the impact prediction.In other words,those resources that will most certainly be impacted wj 11 be gi ven priority over impact issues where there is 1ess ,- confidence in the impacts actually occurring.The result of this dual prioritization will be the application of mitigation planning efforts in a logical and effective manner.The results of the prioritization process will be sent to approp~iate state and federal resource agencies for review and comment.1I Comment:The Department of Fish and Game does not consider what appears to be a subjective r'anking of resources in their 1I 0rder of importance"to be a satisfactoY'y approach to addressing impact issues.There is no substitute for a factual assessment of data voids,studies to fill these voids,and a rational approach to impact assessment based on factual evidence.Ranking as suggested here only supports this Department's long-time conviction that adequate information to make reasonable impact analysis and mitigation plan development cannot be done in the time frame established for the FERC license application by the Legislature and APA. The fifth paragraph of this section states: - Mr.John D.Lawrence -4-December 30,1981 - - "Mitigation for each impact issue will be considered according to the types and sequence identified by the CEQ (Figure 2).If a proposed form of mitigation is technically infeasible,only ~artially effective,or in conflict with other project objectives,the evaluation will proceed to the next form.All options considered will be evaluated and documented.The result of this process will be an identification and evaluation of feasible mitigation options for each impact issue and a description of residual impacts.II COITITIent:The statement in the second sentence of this paragraph,"or in conflict with other project objectives,"indicates equal consideration of fish and wildlife values would not be given in the mitigation planning effort conducted by Acres American.Terrestrial Environmental Services and APA.It is doubtful that any fish and wildlife impact issue would not be in confl ict with APA 's primary objecti.ve to construct the Su Hydro Project, and automatically mitigation alternatives would generally fall into the compensatory realm of mitigation defined in Section 3.5.This Department will closely examine the products of the impact evaluation and mitigation planning effort to be sure equal consideration is given to fish and wildlife resource values and that summary and arbitrary dismissal of fe'asible mitigation alternatives which may be in conflict with "project objectives"is not the primary factor in arriving at a mitigation plan. .Paragraph 7 of this section states: "Additional items that may be addressed by the Core Group include an identification of organizations qualified to execute the mitigation plan and recommendations concerning the staffing,funding and responsibil ities of the mitigation monitoring team." Comment:The Core Group may make its recommendations,but agencies such as this Dep~rtment with a direct responsibility for the management of fish and wildlife resources will in accord with its resource management and protection responsibilities.make its own recommendations to define staffing or funding levels and responsibilities for the mitigation monitoring team.It is our view that APA and its subcontractors do not have oversight on mitigation alternatives or means of implementation. Mitigation and the final approval of its acceptability lies with this Department and other resource agencies with similar mandates.It will be the obligation of APA to implement mitigation plans in accord with the approval of these agencies.In addition,it appears that the II mitigation review groupU is responsible for "informal agency review and comment"on the proposed mitigation options.This informal review is uconsidered by APA and the Core Group prior to the preparation of ••.mitigation plans." However,the option being reviewed (informally)by the mitigation review group are those developed by the Core group in Step 2 ..This needs to be clarified. In paragraph 8 of this section it states: Mr.John D.Lawrence -5-December 30.1981 "During the implementation of the plan.which will include both the construction and operation phases of the project until further mitigation is deemed unnecessary,the mitigation monitoring team will review the work and evaluate the effectiveness of the plan (Step 5).To accomplish this goal,the monitoring team will have the responsibility of assuring that the agreed upon plan is properly executed by the designated organizations.The team will be provided with the results of ongoing monitoring efforts.This will enable the team to determine in which cases the mitigation plan is effective.where it has proven to be less than effective.and also in which cases the predicted impact did not materialize and the proposed mitigation efforts are unnecessary.The monitoring team will submit regularly scheduled reports concerning the mitigation effort,and where appropriate, propose modifications to the plan." Comment:It should be resolved now as to who pays for the participation by agencies in the mitigation monitoring team.The APA should state its commitment to funding participation by agency team members or mitigation study groups. General Comments 1.This Department does not believe adequate opportunity will be afforded the natural resource agencies to evaluate or review mitigation plans due to the accelerated nature of APA1s schedule. To date,for example,the Fisheries Mitigation Task Force Review Group has not been afforded an opportunity to assess ongoing impact assessment and mitigation plans being developed by Terrestrial Environmental Services. Also,the Department has relayed to the APA on numerous occasions our concern that a more extended period of fisheries studies needs to be performed before adequate impact analysis is made and thence feasible mitigation alternatives developed. 2.A section outlining the membership and relationships of the Mitigation Task Force,and Core Group will need to be included. I am interested in obtaining a copy of a plan that clearly sets out the schedules for formal review of specific products by appropriate agencies in order that this Department can adequately respond in a timely and responsible manner to APA. If you have questions,please do not hesitate to contact us. Sincerely, .~.na~d~.Skoog ;..OlT1lll1 SSloner ,- .- I- WI Ll.ETT 1-WITTEBEARY '"~'1"........1.-"...Ronald O.Skoog !...HAYDeN r ""-issfoner l.AMB J'I aska Department of Ff sh and Game ..l.AWRENCe p.O.Box 3-2000:-SINCLAIR Al:'VANOEABURGH"~eau.,.aslea 99802 '(\(/'{b,"ft,l/T oar f,1r.Skoog: -'{...I-r~ CARLSON FRETZ JEX_I-+=Lo""w-R--e-Y----;:Lb..ar Hr.Skoog: SINGH February 23.1982 P5700~11.92 T.1527 Susitna Hydroelectric Project COD1I1ents on Fish and W1.ld11fe mtiaation Pol fey . -I 1-+----4iI.'Ie....appreciate receiving your corrments on the IIS us itna Hydroelectric I-+-----Rrroject Fish and Wl1dlife r.11tlgation POlicy'l dated December 30,1981. -~.==~_~l~..n addition to addressing your comments in our revised edition of the r+=B;~~~~E=A=D--_~~.ili~y,I have elected to respond directly to the concerns you have f-+.;::,,;:..,;c...;;....---r,iQ=ised.My comnents are organized in the order presented in your _~~r,ecember30 letter. ~~CH~A~S~E ~.Section·l -Introduct1on -I-+-------tl"ur defin1t1on of fish and wildlife resources incl uded·the habitat which .::ustains them but for clarification we will include the phrase Pand the ~---------.~tabitat that sustains them"as you recommended. ~ Corrment:We accept the CEQ definition and priority sequence for mitigation. 2.Section 2 -legal ~~ndates We accept that the implementation of mitigation is the eventual goal and will include the phrase lI an d eventual implementation"as you recor:tncnded. Comment:.APA is committed to implement appropriate mitigation plans. - -3.Section 2 -Protection'of Fish and Game To broaden the perspective of the first sentence in the first paragraph we will substitute the word mitigate for reduce.The definition of mitigate in this context being avoid.minimize,rectify.reduce or Mr.Ronald O.Skoog compensate Tor impacts. February 23,1982 page 2 Comment:Avoidance of impacts will be the first mitigation option explored. 4.Section 2 -Federal Energy Regulatory Commission,2nd paragraph We will add the phrase "measures and"in the last line of this paragraph. Comment:This addition meets your request. 5.Section 3.3 -Implementation of the Mitigation Plan It is our intent to reach an agreement,through FERC.with those resource agencies having the mandate to approve the mitigation plan and the implementation specific agencies have not been stated since it is not considered appropriate for APA to define other agencies mandates.-It is also considered inappropriate to discuss such agreements through an informal group such as the Susitna Hydro Steering Committee. Comment:APA accepts that the proposed monitory body or its function would not supersede individual agency mandate.In fact such,monitoring may be conducted through agencies fulfilling their mandates.. 6.Section 3.4-Modificationofth~Mitigation Plan APA intends to work with the appropriate state and federal agencies during implementation of·the plan.including any modifications.The Federal Energy Regulatory Commission must approve any modification to mitigation stipulation in the license.It is anticipated FERCwould not approve these modifications without first consulti.ng with the appropriate agencies •. Comment:It was not intended to impl y APA approval superseded the mandate of state and federal agencies. 7.Section 4 -Approach to Developing Fish and Wildlife Plans Third paragraph: The intent of the ranking of resources is "order of importance was to direct mitigation efforts towards those resources where,even without an . extensive data base,it is predicted the greatest impacts would occur. As an example,the concentration of the fisheries mitigation efforts has been towards the anadromous fisheries between Talkeetna and Devil Canyon,as this is an important reserve and there is higher potential for impact in this section than further downstream. ACRES AMERICAN INCORPORATED ~~._~.-_-____c ---_-c----.c .__c__c.~_..__ - Mr.Ronald O.Skoog February 23,1982 page 3 - - Comment:The delay in the license application will permit a more detailed mitigation plan to be developed. fifth paragraph: Comment:The intent of this procedure is to consider each impact issue and to review all practicable mitigation options within the intent of the National Environmental Policy Act.If a mitigation option that avoids an impact is identified which is technically feasible,effective and not in conflict with any other project objective,the need to address other alternatives was not considered necessary.The intent of sentence.2,paragraph 5 was to state that if such an option does not exist,we will pro- ceed to evaluate other options.. No mitigation options will be arbitrarily dismissed.As stated in the policy,"ALL options will be evaluated and documented." The policy will be revised to make this clear. Paragraph Seven: Comment:FERC requires APA to prepare a mitigation plan prepared in consultation with appropriate resource agencies.This plan will be based on.recolmTlendations from the core groups and review and comment from the agencies via the fish and Wildlife Mitigation Review Group and the formal agency review process .. SUbsequent to the FERC filing,the plans will be reviewed by fERC and other agencies and an acceptable plan finalized.It is not APA's intent that the mitigation planning be in conflict in any way with the management and protection responsibility of any agencies.. Paragraph Eight: Comment:The Susitna project is being prepared by a state agency.As such,it would be premature to commit funding for involvement of other agencies at this time.. General Comments 1.The three month delay in the license appl ication will permit agency review and input to the mitigation plan. 2.The Policy will be revised to include a description of purpose of the core and review groups.You will be receiving a letter with the Feasibility Report outlining what reports will be sent to your department. ACRES AMERICAN INCORPORATED Mr_Ronald O.Skoog February 23,1982 page 4 We very much appreciate your comments on the policy and hope my responses are satisfactory.If you have any questions,please call. ~EfelY yours, 4;;?~~~ (,'~hn D.lawrence Project Manager MMG/jh ACRES AMERICAN INCORPORATED FISH AND WILDLIFE SERVICE JO]I E.TUDOR RD_ ANCHORAGE.ALASKA 99503 (907)276-3800 ..- - .•N REPLY REFER TO: .WAES United States Department of the Interior RECEIVED JAN 12 1982 ACRES ~filW fMC8IPDUIO - Hr.Eric You1d Executive Director Alaska Power Authority 333 Y.4th Avenue Anchorage.Alaska 99501 Dear Mr.You1d: 30 DEC 1981 This lett~r responds to a request by John Lawrence of Acres American that the Fish and t,ildlife Service (FWS)review the Fish and Wildlife Mitigation Policy for the Susitna Hydroelectric Feasibility Study.The request was made by letter dated November 19,1981.Our review of the Alaska Power Authority's (APA)Policy Statement has been undertaken in light of the FWS Mitigation Policy (Federal Register Vol.46.No.15.January 23,1981).We have enclosed a copy of our Mitigation Policy and havepreviously transfer~ed a copy to your subcontractor,Terrestrial Enviromental Specialists.Inc.(see enclosed letter ~dated 4 June 1981).By maximizing consistency between the two policy ____~tatements,avoidance of policy disagreements between the APA and the Ft~S can LU'.:A POW£R e accomplished.Long-term benefits would accrue throughout the process AUTHORITYS.".~.ITNA ·ncluding when and if project mitigation monitoring is in place and modifica- ...:=JI""':::ions to ongoing mitigation c'Juld be evaluated under one policy.:nt P5700 ~~~==/::/===J riefly,the Service's mitigation policy reflects the goal that the most .Q~NC£NO.important fish and wildlife resources should receive the greatest level of i ,~itigation when the environment of a particular area is changed.The FWS F;•~~,-L·olicy divides the mitigation planning process into three components:(1) ~f_~resource category determinations;(2)impact assessment;and (3)mitigation 0:~5 recommendations.By creating four resource categories.the FWS can vary the ...Y)..~,Q ~degree of mitigation it recommends according to the value and scarcity of the ~-habitat at risk.~C·"" ~'_D_!._Our resource category •..•••determinations will contain a technical rationale -I~OA~consistent with the designation criteria.The rationale will:(1)outline ~';;the reasons why the evaluation species were selected;(2)discuss the value of ·WH the habitats to the evaluation species;and (3)discuss and contrast theIIipsrelativescarcityofthefishandwildliferesourceonanationaland JLr._'~-lf:-l---IeCoregion section basis."(F.R.Vol.46.No.15.p.7658).Special con- ~sideration would be given to notable,•·•••aquatic and terrestrial sites _i :"5 :including legally designated or set-aside areas such as sanctuaries ,fish and-'.~:i~TL -wildlife management areas,hatcheries.and refliges.and other aquatic sites ~"such as floodplains.wetlands.mudflats.vegetated shallows,coral reefs. -;IRV -riffles and pools.and springs and seeps.(F.R.Vol.46,No.15,pp •...J _ HRC 7658-7659)~.In the aforementioned sites.the mitigation goal to which the Service would strive for is either no'loss of existing habitat value (Resource--''''---1 Category 1)or no net loss of in-kind habitat value (Resource Category 2)• ....rfllE °Nr.Eric Yould Page 2 The Service intends to recommend mitigation where a biological change constitutes an adverse impact.Our evaluation of project impacts and recommended mitigation would be based.to the extent applicable,on the Service's Habitat Evaluation Procedures and Instream Flow Incremental Nethodology.Both of these methodologies have been suggested to APA and its consultants on several occasions.It should be recognized that streamlining the mitigation process can be accomplished by conformance between the Service's and an applicant's impact assessment techniques.The larger the proposal,the greater the potential savings in time.This idea was a principal behind the formulation of our mitigation policy and adoption of official evaluation procedures. In accordance with our mi tigation policy.··The Service may recommend support of projects or other proposals when the following criteria are met:(1)they are ecologically sound;(2)the least environmentally damaging reasonable alternative is selected;(3)every reasonable effort is made to avoid or minimize damages or loss of fish and wildlife resources and uses;(4)all important recommended means and measures have been adopted with guaranteed implementation to satisfactorily compensate for unavoidable damage or loss consistent with the appropriate mitigation goal;and (5)for wetlands and shallow water habitats.the proposed activity is clearly water dependent and there is a demonstrated public need."(F.R.Vol.46.No.15,p.7659). Specific comments: 1.0 Introduction:This section should include a discussion of the need to adequately assess the environmental resources of the study area to determine the environmental compatibility of a proposed project and to evaluate mitigation to adequately reduce or avoid negative impacts to environmental resources,including fish and wildlife resources,so that no net loss of habitat value occurs. 2.0 Legal Mandates:It should be recognized that the intent of the specified laws and regulations is that project-relate~adverse biological impacts be fully mitigated.In addition,that a plan be developed.acceptable to the resource agencies with mandated fish and wildlife management responsi- bilities.and implemented as a component of the proposal. 2.2 National Environmental Policy Act (NEPA):It is the responsibility of the lead federal agency.the Federal Energy Regulatory Commission (FERC),to fully comply with NEPA. 2.3 °Federal Energy Regulatory Commission:Regulations for."Application for License for Major Unconstructed Projects and Major 1-lodified Projects,·' (F.R.Vol 46,No.219.November 13,1981)were adopted December 14.1981. References in your policy to FERC regulations should reflect this.It should be recognized that within the Exhibit E,"The applicant must provide a report that describes the fish,wildlife,and botanical resources in the vicinity of the proposed project;expected impacts of the project on these resources;and mitigation.enhancement,or protection measures proposed by the applicant.The report must be prepared in consultation with the state agency or agencies with responsibility for these resources,the U.S.Fish and ~ildlife Service.the National Marine Fisheries Service (if the proposed project oay affect anadromous. estuarine.or marine fish resources),and any state or federal agency with I~ -I Mr.Eric Yould cc:FWS-ROES,WAES Quentin Edson,FERC NMFS,EPA,NPS,BLM,USGS J ADEC,ADF&G Carson/ADNR Lawrence/Acres American---- Page 5 February 24,1982 P5700.11.71 T.1528 Susitna Hydroelectric Project Fish and Wildlife Mitiqation Policy •"'.elvin A.r-1onson ting Assistant Regional Director S.Fish and Wildlife Service 11 E.Tudor Road chorage,Alaska 99503 ar Mr.Manson: / ank~u for your letter of December 3e,1981,co~enting on the Fish d Wildlife Mitigation Policy for the Susitna llydroelectric Feasibility udy.We appreciated receiving a copy of the F&WS Mitigation Policy d your explanation of it. o Introduction: will attempt to aespond to each of your comments,numbered as 1n ur letter. This section was purposefully kept short so that the pol icy vrould not be overbearing.He do not feel it necessary to discuss the issues you mentioned,as they are covered in detail in the Feasibility Report.At the suggestion of the Alaska Department of Fish and Game, we have added the phrase "~lida and \'l1ldlife resources of the state". 2.0 Legal ~andate: The entire policy and particularly sections 3 and 4 explain that APA intends to develop and impler.ent a mitigation plan in coordination with the agencies with mandated fish and wildlife mitigation responsibilities •. 2.2 National Environmental Policy Act: Since FERC is a federal a~ency,they are covered by the statement "Federal agencies shall to the fullest extent possible~. WILLETT WITTE BERRY (I1r- " v 'HAYDEN U LAMB 11 '--t::AWRENCE 1\ SINCLAIR . VANOERBURGH n. I v-IC To"tJh A(r",,f-.y _I _,",:.~ CARLSON T FRETZ JEX "" LOWREY ::>. SINGH ~ 1 ~.HEAD \, '"r-toOVE I c.H()ov'<T.f..J J CHASE I , Mr.Melvin A.Monson·February 24~1982 page 2 2.3 Federal Energy Regulatory Cotmlission The policy will reflect the fact these regulations were adopted. Exhibit E will be prepared as described in the regulations. 2.4 Fish and Wildlife Coordination Act Reference to FERC has been incorpora ted. 3.1 Basic Intent of the Applicant The statement liThe FERC will resolve any disputes which APA and the agencies cannot resolve"has been added. 3.2 Consultation with Natural Resource Agencies and the Public A section explaining the mechanism for coordination with the agencies has been added to the beginning of the policy.The agencies will be involved in the plan both prior and subsequent to FERC filing. 3.3 Implementation of the Mitigation Plan The implementation of the mitigation plan is recognized by APA to be its responsibility. 3.4 Modification of the Mitigation Plan Paragraph 2 It is recognized any modification to or termination of the mitigation efforts would be subject to FERC approval.It is assumed FERC would consult with the agencies during this process. 4.0 Approach to Developing the Fish and Wildlife Mitigation Plan Paragraph 3 The intent of this paragraph was to direct mitigation efforts towards those resources where~even without an e~tensive data base~it is predicted the greatest impacts would occur.As an example~the concentration of the fisheries mitigation efforts has been towards the anadromous fisheries between Devil Canyon and Talkeetna~as this is an important resource and there is a higher potential for impact in this section than further downstream. Paragraph 5 The intent of this procedure is to consider each impact issue and to review all practicable mitigation options within the intent of the National Environmental Policy Act.If a mitigation option is identified that avoids an impact~is technically feasible~effective and not in conflict with any other project objectives~the need to address other al ternatives ",as not considered necessary.The ACRES AMERICAN INCORPORATED Mr.Melvin A.Monson February 24,1982 page 3 intent of sentence 2,paragraph 5 was to state that if such an option does not exist,we will proceed to evaluate other options. As stated in the policy,"All options will be evaluated and docu- mented."The pol icy wi 11 be revised to make this clear. Paragraph 7 This paragraph has been expanded to include the Fish and Wildlife Mitigation Review Group involvement in the plan1s development. Paragraph 9 Your statement has been incorporated. Paragraph 10 We agree with your statement.The FERC must approve any modification to mitigation stipulations in the license.It is anticipated FERC would not approve the modifications without first consulting with the appropriate agencies. Thank you again for your time.If you have any questions regarding my responses,feel free to contact me. Sincerely yours, 4~'Z?/?,~~ ~"D.Lawrence Project Manager MMG/jmh cc:E.Yould,APA K.Schreiner ACRES AMERICAN INCORPORATED RECEIVED JAN 041982 AtRlS AhtUUCl\t~UicuRrU\\lUD December 31,1981 Mr.John D.Lawrence Acres American,Inc. 900 Liberty Bank Building Main at Court Buffalo~New York 14202 UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National,Marine Fisheries Service P.O.Box 1668 Juneau,Al,aska 99802 Dear Mr.Lawrence: ,.•' Realizing that Section 4,step 3,development of an acceptable mitigation plan,is to be completed by March 1982,we assume that steps 1 and 2 of the same section are by now substantially completed. Yet,contrary to the second sentence of 3.2,"During the early stages of planning,representatives of state and federal agencies will be encouraged to consult with the applicant and the applicants representatives,as members of the Mitigation Task Force.", we have yet to be contacted regarding the status of this impor- tant element,and the Mitigation Task Force review committee has not met as of this date. 3.3 Implementation of the Mitigation Plan We are pleased to see the plan include provisions for post- construction monitoring of mitigation measure?and opportunities. 3.2 Consultation with Natural Resource Agencies &the Public v We have received your 1etter of November 19~1981,requesting the comments of the National Marine Fisheries Service (NMFS)on the Fish arid Wildlife Mitigation Policy for the Susitna Hydroelectric Project.Having reviewed the statement we offer the following comments. The statement adequately reflects the intent of such a mitigation policy and presents an accurate overview of those legal mandates which require mitigation to be considered in designing hydroelectric projects.We have several specific comments dealing with the operation of the proposed mitigation plan,which follow. 3.1.Basic Intent of the Applicant The last paragraph states that this methodology outlines a process for resolving conflict between the Power Authority and resource agencies.We do not feel this has been satisfactorily accomplished within the general policy statement (Sec.3)and suggest additional effort be made to establish such a conflict resolution methodology. - - - The applicant should note,however,that such a provision will be integral to the mitigation plan and the associated costs should be included with the license application,and not IIresolved through parties after the mitigation plan is complete.1I This is supported in the FERC regulations,4.41 (F)(3)(iv)(D),which require Exhibit E to contain an estimate of the costs of construction, operation,and maintenance of any proposed facilities or imple- mentation of any (mitigation)measures. 3.4 Modification of the MitigatiQn Plan The last sentence,dealing with termination,should state that termination of any mitigation measure stipulated in the FERC license will require an amendment to that license. 4 Approach to Developing the Fish and Wildlife Mitigation Plans Paragraph 3,sentence 6.Change 'will I to 'may',as priority will be assigned both by the likelihood of impact and sensitivity of the resource. Paragraph 5,sentence 2.The fact that a form of mitigation is in conflict with project objectives or only partially effective should not prevent it from further consideration.Such a statement strains the term IIreasonable alternatives ll and does not comply with the spirit or intent of the National Environmental Policy Act. Paragraph 7.As outlined,no formal agency input into the mitigation plan will occur prior to application to FERC.FERC regulations require Exhibit E to contain a report describing proposed mitigation measures,prepared in consultation with state and federal resource agencies.The process described here falls short of this required consultation.We suggest formal agency review of the draft fisheries and wildlife mitigation plans occur prior to license application. We appreciate this opportunity to comment. SinC~relY,._.~·i.~;;_._.//.!r~7/'~/."v----~ ."./lr Robert'W.McVey , I .Direttor,Alaska Region,.....'. \..../.. ..... February 23,]982 P5700.11.91 1.1424 Susitna Hydroelectric Project . Ffsh and W11dl1feMftfqatfon Policy nk you for your December 31,1981 response to our request for nts ,on the Susitna Fish and Wildlffe Mitigation Po1fcy.I have nd~d to your comments in the order fn which they were presented. Basic Intent of the Applicant pproach to resolvfng ffsh andwf1d11fe mitigatfon conf~icts between nd the.resource agencies fs outlined fn Step 3,Section 4,of the atfon Policy.As stated.ft basically involves revie'tr and cornent e Ffsh and Wfldlife Mftfgatfon Review Group representing the rce agencies.In acdition,although not specifically stated. r policy,any draft mitigatfon plans will be submitted to resource 1es for formal comment and reviewprfor to the submissfon of a 1icense application.Our policy will be modified to include this. Consultation with Natural Resource AClencies and the Public Mr.Robert W.McVey tor,Alaska Region nal Marine Fisherfes Service Box 1668 u,Alaska 99802 Mr.f1cVey: on 4,step 3.Development of an Acceptable f'!itigation Plan.,.,.111 e completed by March of 1982.Ho~ever.mit19ation options ~n11 sessed and preferred options to~ether with their technical feaxt- b11ity and potential effectiveness will be presented in the March 1982 Feasibility Report.. The first meeting of the Mitigation Review Grqup will occur in March.1982. An invitation will be sent to Bradley Smith as a representative of your agency.This meeting will provide the resource agencies with an opportunity to discuss,~/ith the Hitigation Core Groups,the varfous mitigation options presently being considered.The details of a draft mitigation plan will be completed subsequent to the Feasibi1fty Report and prior to the FERC license application. 3.4 -r·~oclification of the ~l1tiqatfon Plan We agree that the termination of any mitigation measure stipulated in the FERC license would require FERC approval.In regards to the mon- itoring program,we anticipate that the FERC license will allow for r r I irec I WILLETT atforWITTE.0.BERRY,~unea I r..L ear "HAYDEN I LAMB I J LAWRENCE tha..SINCLAIR :VANDERBURGf-(ormte ""'spaI1.t-rc>4>of,-. r..!.1 - CAALSON I FRETZ I JEX .\.ur a-LOWREY tpA a SINGH •it hie /'1:~r....;y I.A:l th ~'I'~SOu 'J,~.I auSTEAD I~BaVE ClyenC I F RC """2 - CHASE oJ I I ~f"cti rot b I ,,~as Mr.Robert W.McVey February 23~1982 page 2 the termination of the monitoring program when the need for further mitigation is considered unnecessary.We have modified the policy to state termination would be subject to FERC approval. 4.4 -Approach to Developilig the FiSh and Wildlife Mitigation"Plans Paragraph 3~sentence 6~refers to the functioning of the Mitigation Core Group which will be concentrating its efforts towards resources most likely to be impacted.. Paragraph 5,sentence 2.This sentence is ~ontained under Step 2 en- titled "Option Analysis Procedure ll •The intent of this procedure is to consider each impact issue and to review all practicable mitigation options within the intent of the National Environmental Policy Act. If a mitigation option that avoids an impact is identified which is technically feasible,effective,and not in conflict with any other project objectives.the need to address other alternatives was not considered necessary.The intent of sentence 2,paragraph 5,was to state that if such an option does not exist,we will proceed to evaluate other options."All options considered will be evaluated and documented. The result of this process will be an identification and evaluation of feasible mitigation options for each impact issue and a description of residual imp"acts.II The selection of which options are to be further considered in the de- velopment of an acceptable mitigation plan is addressed under Step 3. Paragraph 7.Mitigation options wlll be forwarded to the Fish and Wildlife Nitigation Review Group allowing for agency review and corranent. In addition,our mitigation pol icy will be modified to reflect our intent to have the draft mitigation plan formally reviewed by agencies prior to application to FERC. I appreciate your comments and trust our response satisfies the concern you have expressed. Sincerely, 6~~~ John D.Lawrence Project Manager KRY/jmh ACRES AMERICAN INCORPORATED u.s.ENVIRONMENTAL PROTECTION REGION X 1200 SIXTH AVENUE SEATTLE,WASHINGTON 98101 AGENCY _~~'f"::'J R I='~~C_i.:-----.- FEB 8 lS3Z , ACRES A~ffilCAX UtCURPOrJ.lEB REPLY 10 M/S443....nN OF, 4 FEB 1982 Kevi n R.Young Acres Ameri can Incorporated The Liberty Bank Sui ldi ng Ma in at Court Buffalo,NY 14202 Subject:Susitna Hydroelectric Project Fish and Wi ldlife Mitigation Policy and Draft Analyses of Mitigation Options . Dear Mr.Young: .-AL "POWER .jOIlITY .iITNA Thank you for sending us copies of the above papers for our review.From conversations with Mike Grubb,of your staff,we understand that Acres American has decided that further work is necessary on the mitigation options papers before agency comments will be solicited.Therefore,this letter will-address EPAls comments on the mitigation policy paper only • In general,we believe that the overall mitigation approach is good.>In particular,the ~se of the CEQ definition of mitigation encourages the most satisfactory types of mitigation to be considered first.This is reflected in Figure 2,OptiDn Analysis.The establishment of a long-term monitoring plan and acknowledgment that the mitigation plan willbe ch ang ed if necessary is also commendab leo We do have spme concerns about implementation of this policy,especially over the next year while the mitigation plan for the FERC license appli- cation is still being developed.Some issues and mitigation measures must be incorporated into the pre liminary engineering and design stages of the projects and,from our review of the Acres Jlmerican reports,we are aware that this is being done.One good example is spillway design to avoid nitrogen supersaturation.However,there are a great many other issues r-c--I-'----'=---1,.....,"-'-~where the agencies and the public do not have sufficient information yet on the impacts to judge either how much mit i gat ion wi 11 be needed or what ----'-'1--.--..sort of mitigation might be successfu~·.For example,EPA will not have any pre-and post-project water Quality data unti 1 the feasibi lity study is ci~culated (letter fro~Johri n Lawrence to John R.Spencer,January 4, 1982·.)Development of an option analysis VJhich r"€f1ects the possible suc- l-'-I-,-,r-R-'V-i--'--'-''I',cessful mitigation measures for the entire range of potential impacts, --.H RC inc luding the wars t case,appears to be a useful step at thi s time. HO\'/ever,the agencies and the public may have difficulty eva'luating the1._~J, .,.rll,.I I r.~~_:"lil.~J J" -J_J.='.I AiLEl -------'--..j adequacy of a mitigation plan until more impact information is available. EPA would have been faced with this situation in reviewing the fishery mitigation plan if Acres American had wanted our comments at this time. We have one other suggestion for your consideration.Because of the location and magnitude of the impacts,new mitigation methods or methods new to this region of Alaska may eventually be identified.Because it will be several years before the mitigation plan is finalized,it may be possible to test the feasibility of some of these ideas before mitigation itself must start.Such an approach may have long-term environmental and economic benefits. Some additional minor comments are presented in the attachment. We look forward to reviewing the option papers.If you would like to dis- cuss our comments,Judi Schwarz of the Environmental Evaluation Branch may be contacted for more information.She can be reached at (206)442-1096. Sincerely, ~"IO~~~eal,Director Environmental Services Division cc:Al Carson,DNR Dave Wozniak,APA .... "'.. Susitna Fish and Wildlife Mitigation Policy Attachment· FERC Regulations For your information.FERC published the new regulations on license applications on November 13,1981.The section of fish and wi ldlife mitigation can be found at 46 FR 55938.FERC has made some wording changes,but the substance is essentially unchanged. Definit ions The policy statement refers to a Mitigation Task Force,a Mitigation Review Group,and a Core Group of the Mitigation Task Force.The com- position and method of selection of each group should be described • February 23,1982 P5700.11.91 T.1526 Susitna Hydroelectric Project Fish and Wildlife MftiQation Policy ank you for your letter of February 4,1982 regarding the Susitna sh and \~ildl1fe Mitigation Policy. will be discussing Hitigation further in early riarch meetin§s with e Core and Review Groups and attempting to focus in on the major pact issues and define further studies necessary to develop adequate tigation.You will be invited to this meeting. ank you again for your COffiffients. •Gary O'Neal,Director vironmental Services Divisions.Environmental Protection Agency gion X 00 Sixth Avenue attle,Washington 98101 ar Mr.lO'rteal: WILLETT WITTE BERRY IV HAYDEN fIr LAMB n SINCLAIR l. VANDERBURGI-(e I... V'Y"vIJ£-.f&- Ie, x ('l,,"vhh V CARLSON FRETZ L 1'=' JEX ,LOWREY SINGH Ih "p ~~,...~u .....1-; ---,STEAD I'1C BOVE th .n.. hi CHASE "T Sinccra!Y, &--- John D.La\'lrcnce Project r,~anager ~rtMG/jh cc:E.Yould,APA J.Spencer,EPA pllI\ I .- :Terrestrial nvironmental Specialists,inc. R.D.t BOX 388 PHOENIX,N.Y.13135 !3fl5llll!l-7228 MEMO TO:Members of the Fisheries Mitigation Technical Group FROM:Russell J.Nemecek DATE:November 25,1981;218.880 RECEiVED NOV 30 1981 Enclosed are initial evaluations of impacts and mitigation options available for operational flows on the downstream fisheries and the flooding of streams in the impoundment zones.Please review this material before our December 10th meeting in Seattle,since this will be the essence of our discussions.If you have any comments or additional input to make prior to our meeting,please contact me. - RE:Mitigation Options ALASKA POWER "',UTHORiTY SUSITNA1-- FILE P5700 _"-// ..:::Jt) SEQUEr~CE NO. ;=:-:.,:)j ifd- ,I . o_'z ;,:~.~~II ~_:..J '-;9,.....<l: u::..;:~'2 I E<l:l:c:.:!0 z -1-1_-~I r't"'"I J I j-r-;l1i§![~'~ -I-~c.t;I \-i-I--J D ::I -1"7~il 1 --i-Tr3 I-1--1.-'-;j!PG H II'-I-I'~r'~'~,--1'-1's ~;Ti------! I D.\;L' --f":.";:~"1-- -1------ I '."~~J_'l~._LP1IDett--1 ---1---,1- -~~~l- DIVISION OF RESEARCH &DEVELOPMENT December 9,1981 Mr.David Wozniak Alaska Power Authority 334 West 5th Avenue,2nd Floor Anchorage,Alaska 99501 Dear Mr.Wozniak: fA r s.HAMUOltO.&Orr'ltOIl 323 E.4TH A VENUE ANCHORAGE;'A~ASK,,\99501 The Susitna Hydroelectric Steering Committee (SHSC)would like to receive additional information from your office regarding the status and progress of the Mitigation Task Force.As you know,preparation of an adequate Federal Energ~egulatory Commission (FERC)license application requires that Exhibit E identify the proposed measures to mitigate impacts or to protect and en- hance the resources.We believe coordination of this vital study item should occur early and on a continuing basis.I am aware that the APA has also recognized this need by creating two Mitigation Task Force core groups composed of principal investigators and a Mitigation Review Committee com- posed of representatives of various concerned agencies.While several mem- bers of the Review Committee sit on the SHSC,they have received no informa- tion on the progress of either core group.Additionally,the Fish and Wild- life Mitigation Policy recently developed by APA for the Susitna Hydroelec- tric Project stresses the need for close coordination.Although no time schedule is established in this mitigation plan,it is obvious that steps 1 and 2 (identification of impacts,ranking of impacts and identification and review of mitigative alternatives)should be substantially completed by now if step 3 (development of an acceptable mitigation plan)is to be achieved by the March 15.1982 draft feasibility report deadline. Therefore,I am requesting that you provide any applicable information regarding the Mitigation Task Force groups and their progress to date.The minutes from past meetings would be particularly helpful here.As the SHSC is eager to discuss these concerns,I believe a short briefing may be most effective.I will be contacting you to arrange for such a meeting,hopefully during the week of 12/13/81. Sincerely, Al Carson Chairman,Susitna Hydroelectric Steering Committee AC:db cc:Steering Committee R.Stoops Quentin Edson,F.E.R.C. Phone:(907)277·7641 (907)276·0001 DEC 211983 ALASKA POWER AUTIIORITY RECEIVED334WEST5thAVENUE·ANCHORAGE,ALASKA 99501 ACRI:;)nlll~ltlliJ\h lita;thttiORATED December 15,1981 Mr.Al Carson Depart:rcent of Natural Resources Division of Research and Develq:nent 555 Cordova Anchorage,Alaska 99501 Dear Al: Which leads Ire to the key ]?Oint;when will an assessrrent be p::>ssible?'The rrost carprehensive will appear in the draft feasibility re]?Ort,to be published March 15,1982.A less canprehensive,but I am in receipt of your letter of December 8,1981 soliciting (on behalf of the Susitna Hydroelectric Project Steering.Corrmittee) additional infoZTIB.tion concerning the Mitigation Task Force.- I am happy to canply,in part because it affords Ire an opp::>rtunity to correct some. apparent misconceptions. Second,you misjudge slightly our -tirretable on mitigation planning. We are just now in the midst of ide.ntification of inpacts.Physical constraints have led to this tirretable:Field studies had to be corrpleted and surrmarized,hydrology data formulated so that p::1>V€r generation simulation (which leads to water release/stage infoZTIB.tion) could be done,etc.We have by no rrearts fully scoped irrpact yet,but we are rapidly advancing. First,while I have no objection to Steering Ccmnittee participation on our mitigation planning,I am scmewhat surprised.As was rrade clear early on,mitigation planning (and specifically the Mitig~tion Task Force Review Group activities)is being done within the fo:rmal ccordination and consultation frarreY.Drk of the Fish end Wildlife Coordination Act and F .E.R.C.Regulations.By contrast,the Steering Carrnittee has worked vigorously to remain infornal cormentators to the Sustina Hydroelectric Project prop::>sal.If the Steering Comnittee elects to join us in mitigation planning,it should ~understood that we will t.reat their participation as "fornal".That in turn leads to other minor procedural concerns,such as what to do about dual 11 representation,etc. ALASKA 'POWER AUTHORITY SUSITNA FILE P5700.1/ SEQUENCE NO. I F ~JqL/ I z 'i ai ~:>IX:ii:::!;Ir-a l- LL '"!:;a ~I \.--~Dew -I"':::~,1.-J CAD ----'- -JOG-1--.:::~WH JPS'-J PGH -l- ENS-SNT-----DWL--I~ MRV--,-HRC_......'!k.e'l ...-~1>7~I--- ---v FILE -~J: .- ,- - 1 1 1 nonetheless fairly rigorous,assessrrent will be provided to the Review Group when they convene January 20,1982.I knaN you are a rrember of that Review Group.You should be receiving your fonna.l invitation very soon,if not by nON.I suggest Steering Cornnittee involverrent,if any, be subsequent to that convening. FOR 'mE EXEcurIVE DIRECroR DO'IJ/blm Sincerely,12 /jIJ..nDaV~~Prolect Manager I-, cc:John Lawrence,Acres Arrerican (w/cy of Carson letter) Quentin Edson,F .E.R.C. Ms.Janet McCabe Area Di rector U.S.Geological Survey 1011 E.Tudor Suite 297 Anchorage,AK 99501 Dea r Ms.McCabe: December 18,1981 P5700 .11.91 T.1355 Susitna Hydroelectric Project Fish and Wildlife Mitigation Revi ew Group In September of this year the Alaska Power Authority (APA)invited you or a member of your staff to participate in a Fish and Wildlife Mitigation Review Group for the Susitna Hydroelectric Project.To date,APA has recei ved no response. The first Review Group meeting is to be held January 20,1982,at 10:00 a.m. at the offices of APA~Please inform APAifyou will be attending this meeting and if you wish to participate in future mitigation planning efforts. If so,we will 'send material for your review prior to this meeting. Thank you. Sincerely, ..... MG:adh cc.:APA ACRES AMERICAN INCORPORATED 1·~.,;..'=.:~_;.•;.:::~.";- Kevin Young Environmental Coordinator December 18,1981 P5700.11.92 Tl360 Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish &Game 333 Raspberry Road Anchorage,Alaska 99502 Dear Mr.Yanagawa: As a member of the group established to review fish and wildlife mitigation recommendations on the Susitna Hydroelectric Project,I request your atten- dance at a meeting on January 20,1982,at 10:00 a.m.,in the office of the Al-aSka Power Authority.In the first week of January,I will forward for your review,a preliminary outline of project operations,impact issues,and mitigation options as prepared by our design team and the fish and wildlife mitigation technical core groups.I would appreciate receiving by January 30,1982,any written comments you may have regarding our approach,results, or evaluations to date. Following the preparation of the Feasibility Report,which will contain more detailed information on project operations and our evaluation of these oper- ations,an opportunity will be provided for you to perform a more thorough review. If you have any questions relating to this meeting or the proposed functions of the review group,please contact Mr.Dave Wozniak of APA or myself at 716-853-7525. Sincerely, Kevin Young Susitna Environmental Coordinator MG/jk ACRES AMERICAN INCORPORATED Consulting Er.gincers The Liberty ean~6ui::::,ng.r.~aln al Court eu!lalo.Ne·...Yor"~1~2(j2 Te!es;hor.e 71£·853·7525 Preceding Letter Sent To: ,- Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Ms.Juli Schwarz Environmental Evaluation Branch U.S.Environmental Protection Agency Region X 1200 Sixth Avenue Seattle,WA 98101 Mr.Bradley Smith Environmental Assessment Division National Marine Fisheries Service Federal Building and U.S.Court House 701 C Street,Box 43 Anchorage,AK 99513 Mr.Al Carson Department of Natural Resources 323 East Fourth Avenue Anchorage,AK 99501 Mr.Michael Scott U.S.Bureau of Land Management 4700 East 72nd Street Anchorage,AK 99507 Mr.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,AK 99502 January 7.1982 P5700.11.70 1.1395 Mr.Carl Yana~awa Regional Supervisor for Habitat Division Alaska Department of Fish &Game 333 Raspberry Road Anchorage.Alaska 99502 Dear Mr.Yanagawa:Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meetinq Enclosed for your review: l}Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy. 2)Draft ,Q.nalys1s of ~~ildlife nit1Qation Options. 3)Draft Analysis of Fisheries r~itigat1on Options. These documents \~11l be discussed at the Fish and Wildlife Mitiqation Review Broup t-lect1ng to be eeld at 9:0a a.m.(note change of time from-lett~r of Decc~b~r ln,lS31)on Janua~y ZJ.19:2 at the office of the Alaska Pai'i~~~Authori ty .334 l~est 5th A.venue,t-nchoragel;!I hope you will be able to attend the meeting. Sincerely yours. Kevin R.Young Susitna Environmental Coordinator HhG/jr.Jh Enclosures ""'" Preceding Letter Sent To: .... - Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Ms.Juli Schwarz Environmental Evaluation Branch U.S.Environmental Protection Agency Region X 1200 Sixth Avenue Seattle,WA 98101 Mr.Bradley Smith Environmental Assessment Division National Marine Fisheries Service Federal Building and U.S.Court House 701 C Street,Box 43 Anchorage,AK 99513 Mr.Al Carson Department of Natural Resources 323 East Fourth Avenue Anchorage,AK 99501 Mr.Michael Scott U.S.Bureau of Land Management 4700 East 72ndStreet Anchorage,AK 99507 Mr.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,AK 99502 Dear Mr.Yanagawa: February 26,1982 P5700.11.70 T.1543 Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish &Game 333 Raspberry Road Anchorage,Alaska 99502 Susitna Hydroelectric Project Fish and Wildlife-Mitigation As discussed through Vern Smith of our Anchorage office,meetings to re- view fish and wildlife mitigation efforts are scheduled for March 11 and 12,1982 in the offices of Acres American,1577 C Street,Suite 305, Anchorage,Alaska. As these meetings are expected to be in the form of technical workshops, a complete day on each of the topics of fish and wildlife is considered necessary.Proposed agendas are enclosed.I will also forward,within the week,updated information packets addressing fish and wildlife im- pact issues and mitigation options. As fisheries issues are being discussed on a separate day from wildlife issues,please feel free to have different technical personnel attend each of the meetings if you consider it appropriate. As we consider these meetings to be an important component in improving the coordination between your agency and our fish and wildlife mitigation core groups,your attendance is encouraged. If you have any questions relating to these meetings please contact my- self or Vern Smith (907-276-4888). Sincerely, Kevin Young Environmental Coordinator KRY:dlp Enclosures Preceding Letter Sent To: - Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Ms.Juli Schwarz Environmental Evaluation Branch U.S.Environmental Protection Agency Region X 1200 Sixth Avenue Seattle,WA 98101 Mr.Bradley Smith Environmental Assessment Division National Marine Fisheries Service Federal Building and U.S.Court House 701 C Street,Box 43 Anchorage,AK 99513 Mr.Al Carson Department of Natural Resources 323 East Fourth Avenue Anchorage,AK 99501 Mr.Michael Scott U.S.Bureau of Land Management 4700 East 72nd Street Anchorage,AK 99507 Mr.Gary Stackhouse U~S.Fish and Wildlife Service 1011 East Tudor Road· Anchorage,AK 99502 Ma rCM 2.1~B2 P5700.11.7C T.1552 Mr.Carl Yanagawa Reglonal Supervisor for H!tbitat Division Ala5k~Denartment of Fish &Game 133 Raspberr,y Road Anchorage,Alaska 99502 Dear Mr.Yanagawa:Susitna Hydroelectric Project fish and Wildlife Mitigation Review Group r~tinQ Enc10SEC for your information ~re: 1.The Susitna Hydroelectric Project Fish and Wildlife ~ftigat1on Policy (Revised) 2.Wildlife M1tfq8t1cn Option!(Revised) 3.Fisher1es Mitigation Options (Revised) Please review thes~docum~rt~prior to the Meetir.~of the Fish and H'ild11ffl ;~1ti'JFlt1on Rev1~"Grcup on ~~rch10t P,'-l2 at 3:30 a~in the offi c\:s o~Acr(!s fi.~ri C3 it t 1577 C ~treet, Anchorage.~e ,·rill d1scU5~the Poltcy and Hl1dl1fs ~~it1a1'!­ tiDn Options nn th~10th ~~j t~~Fish~ri~s Mftigati~~nM_ tions on the 11th,as refE'rr~(j to fn tk.inv1t;:,tioil l",tter of February 25,1982.' Th;,nl<'yOU vfory IT':ICt;. Since-rely, ~~?vi n ¥O:'I,1l''I' SU$1 t!li'Envi rrmr.Fn1:id Coordini'l:t,Jr KnV:dlp Enclosures .- Preceding letter Sent To: - ..... Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish and Game 333 Raspberry Road Anchorage~AK 99502 Ms.Juli Schwarz Environmental Evaluation Branch U.S.Environmental Protection Agency Region X J200Sixtb Avenue Seattle,WA 98101 Mr.Bradley Smith Environmental Assessment Division National Marine Fisheries Service Federal Building and U.S.Court House 701 C Street~Box 43 Anchorage~AK 99513 Mr.Al Carson Department of Natural Resources 323 East Fourth Avenue Anchorage~AK 99501 Mr.Michael Scott U.S.Bureau of land Management 4700 East72nd Street An~horage~AK 99507 Mr.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage~AK 99502 SUSITNA HYDROELECTRIC PROJECT FISH AND WILDLIFE MITIGATION REVIE~GROUP MEETING March 10,1982 Held at the Offices of Alaska Power Authority,Anchorage Attendees:See attached list. The meeting followed the attached agenda.The revised Fish and Wildlife Mitigation Policy was discussed.Agreement was reached on all areas where further revisions were suggested.The policy will be modified and circulated to the review group members by April 15,1982. Ed Reed and Karl Schneider presented the results of the wildlife baseline studies and impacts prediction.Attendees were provided with the sections of the Feasibility Report addressing these issues. General mitigation options were discussed.HEP was not dismissed but questioned as to its validity to big game species in Alaska.It was agreed some kind of habitat evaluation,in addition to population studies would have to be conducted.TES has developed a habitat analysis method (used on the access road studies)and this may be modified and used.The question of land set aside was also discussed but no decision reached. Ed Reed suggested,for discussion purposes,the option of APA funding a permanent research station in the Upper Susitna Basin.It was agreed this was an option but should be considered only if other options (avoid,reduce, etc.)fail,i.e.it would be used on out~of-kind compensation. Studies for Phase II to quantify impacts and for mitigation planning were reviewed with Attachment A forming the basis for discussion.The BLM burn in the Alphabet Hills may not proceed dur to lack of burn plan being written and possible requirement for an archaeological clearance.APA may contact BLM to determine how a go decision could be reached. fl;'~,,"\J Lv II d JI le ~1/I ~IN b i ,;,-'p ___________--=3f41-?:~/'1/~p:ATL~1'J /i.#7:~;J_G _ -,------'-__0 •_ ---------- LlaP.4 .I-n..s _ -------------------------- &f\"V SM (II-(N ~. ,--------AJ----~~vS=---o""-"---'----&U---e _ ----A...n.-GJ,..%2""-'yz;'--""--5~,t2:_e...L.<IIac..wc...L'h"..:.-<-<;L---____L...:!l·d lye sAmeI':Con,-Re.9~-- ......E.ob"1(/(0 cs e=~,--'"""-_-__~Tf---=.c==--~S"---------__- -----M ;-k .5-kO:iI=.B A.:/Y}---4-_ ______L~o...-'0?~~\~ucs.~~'S wc<.-(ba,S1.-L .S [O',c..4_ko-'="/)6~e-~·._-----=U"---=..S-,-p_.W_._5 _ ___~_L~4.~-r;,(v'b h'de y'~j AVlf'I'\'C 't ~n n_ r-~81-J_KJ;ANE1E.L_s.Lb -----4~&cl~_~o4~s .~_Tg~_t!Q~f:gt:T~L t #t<t-XW/1-&/fWn /1:!2P d <f-_....._---------------- _____/o_~__Ax.~~jJ·IJ[)£-f 6 __.~6/---1b-d /IS :; ___un _!~£h'·114-1<.(.;_;\./{.$> -._~_..J2 m~1JpL,c.U. """-------------------,-------- -------------_._---------------- --------------------------------------------------------- --------------'------------------------------------- --------------~-------------_..----_._-------.---- -------------------------.----.---- ----------------------------- ~. ...._-----_•._---_._----~~- Mr.Karl Schneider Research Coordinator Division of Game Alaska Department of Fish and Game 333 Raspber~Road Anchorage.AK 99502 Dear Karl: March 16.1982 P5700.11.10 T1598 Susitna Hydroelectric Project Proposed Phase II Studies I am enclosigg a copy of the document briefly describing the proposed Phase II Susitna Wildlife and Vegetation studies.This was prepared based on the work of the Core Group and Review Group on March 10-12,1982. I wish to thank you for your time and input during both the review and Core Group meetings.I feel we made real progress toward resolving some of the issues that had been hanging,pBrticularly the wildlife/habitat relationship issue.I understand Dr.Taber will be sending you a brief description of a system he proposes and,following your review,we will proceed to discuss the issue with the Core Group and others whom you feel appropriate.As we discussed,TES will take the lead in arranging for the ,'#Or ks hop. Thank you again for your time;I will be in touch. Sincerely, Michael Grubb MG:ccv Enclosure cc:E.Yould.APA rots.Judi Schwarz Environmental Evaluation BranchManStop443u.s.Environmental Protection Agency Region X 1200 Sixth Avenue Seattle.WA 98101 Dear Judi: March 24,1982 P5100.11.91 11610 Susitna ~droelectric Project Fisheries Mitigation .- As we discussed.I am enclosing a copy of two documentsd1str1buted at the March-19th meeting of the Susitna Fish and Wildlife Mitigation Review Group.One document is a revision of the fisheries document provided to you and other menbers of the group on March 8th.The other document 15 a summary of wildlife and vegetation studies proposed for Phase II of the project.This document was based on Phase I studies.cOll1J1ents from the Review Group on the 10th.and work of the Wildlife Core Group on March 11th and 12th. The Fish andWl1dlife Mitigation Policy was also discussed on the 10th. You w'I11 shortly be receiving what is hopefully the final version of this policy,as the group reached agreement as to the changes and the wordings of these changes during the meeting on the 10th.~,, Your comments on the two enclosed documents are invited.We are particularly interested in your thoughts as to: 1.Are the proposed studies relevent? 2.Do the proposed studies address the issues in question? 3.Which studies should receive priority,should funding become a constraint? Thank you fo1'"your continued role in this aspect of the project. Sincerely, MG:ccv Enclosures cc:E.Yauld -APA Michael Grubb April 1,1982 P5700.11.87 T1633 Mr.Max Brewer Office of the Director Special Assistant for Alaska U.S.Geological Survey 218 East Street Anchorage,AK 99501 Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy Dear Mr.Brewer: Enclos~is the Susitna Hydroelectric Fish and Wildlife Mitigation Policy. This policy is the culmination of a cooperative effort between the Power Authority,its consultants,and the natural resource agencies. Originally initiated in January 1981,this policy has been reviewed and commented upon by the Fish and Wildlife Mitigation Review Group and revised and rei ssued by the Power Authority and its consultants in May,June and . November 1981 and March 1982.It has also been discussed at meetings held with the Fish and Wildlife Mitigation Review Group in January.and June 1981 and March 1982. This policy will serve as the foundation for further mitigation planning for the Susitna Project.We look forward to working with you and your staff in this important effort. Sincerely, ~L.-(V~j\L-~~;0l-f b John O.Lawrence Project Manager JOL:ah Enclosure cc:E.Yould ACRES AMERICAN INCORPORATED C::;nsul:ir.g E~r;i~eers n.e li~e:ly !lank euilc'ng.r.~a;n 31 COurl SH~·a !o.r-le·....YD~r:~:2-02 - I"" - ,~ .-. Letter #3 Mr.Max Brewer Office of the Director Special Assistant for Alaska U.S.Geological Survey 218 East Street Anchorage,AK 99501 Mr.Ernest W.Mueller CO/ll1lissioner Alaska Department of Environmental Conservation Pouch 0 Juneau,AK 99801 Mr.Bob Martin Alaska Department of Environmental Conservation 437 East Street,2nd Floor Anchorage,AK 99501 Mr.John Rego U.S.Bureau of Land Management Anchorage District Office 4700 East 72nd Avenue Anchorage,AK 99503 April 1 5 1982 P5700.11.74 Tl624 Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau 5 Alaska 99811 S~sitna Hydroelectric Project Fish and Wildlife Mitigation Policy Dear Mr.Katz: Enclosed is the Susitna Hydroelectric Project Fish-and Wildlife Mitigation Policy •.This policy is the culmination of a cooperative effort between the Power Authority.its consultants 5 and the natural resource agencies. Originally initiated in January 1981 5 this policy has been reviewed and commented upon by the Fish and Wildlife Mitigation Review Group and revised and reissued by the Power Authority and its consultants in MaY5 June.and November 1981 and March 1982.It has also been discussed at meetings held with the Fish and Wildlife Review Group in January and June 1981 and March 1982. This policy will serve as the foundation for further mitigation planning for the Susitna Project.We sincerely appreciate your efforts and those of your staff in the review of the various drafts of this document and attendance . and input to the meetings.We look forward to working with you on future mitigation efforts.Again 5 thank you for your assistance. Sincerely. John O.Lawrence Project Manager JOt :ah Enclosure cc:E.Yould A.C "'05.'" ACRES AMERICAN INCORPORATED C:~-s.C':lng E!'"g~ne~rs -r-'.e lrte:rty ~~ni(2:,JlI.~;:",.g.·.~a.n at Ccurl :1,."-::0.::e·...·v'Jrtl 1:202 ''''''''Letter #2 Mr.John Katz Pouch M Alaska Department of Natural Resources Juneau,Alaska 99811 Mr.Robert McVey Director,Alaska Region National Marine Fisheries Service NOAA P..0•Box 1668 Juneau,Alaska 99802 Mr.Ron Morris,Director Anchorage Field Office National Marine fisheries Service 701 C Street,Box 43 Anchorage,Alaska 99513 Mr.Keith Schreiner Regional Director U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,Alaska 99503 Mr.Robert Bowker U.S.Fi shand Wildlife Service Western Alaska Ecological Service 733 West 4th Avenue Anchorage,Alaska 99501 Mr.Ronald Skoog Commissioner Alaska Department of Fish and Game P.O.Box 3-2000 Juneau,Alaska 99802 Mr.Thomas Trent Al ask a Department of Fi sh and Game 2207 Spenard Road Anchorage,Alaska 99502 Mr.John R.Spencer Regional Administrator U.S.Environmental Protection Agency 1200 Sixth Avenue Seattle,WA 98101 Mr.Curtis McVee Stat-e Director Bureau of Land Management Federal Building and Court House Anchorage,AK 99513 Mr.Al Carso'n Department of Natural Pouch 7-005 Anchorage,AK 99510 Dear Mr.Carson: Resources April I,1982 P5700.11.74 T1616 Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy Enclosed is the Susitna Hydroelectric Project Fish and Wildlife Mitigation Policy.This version has .been revised based upon·comments received and _ agreements reached at the Fish and Wildlife Mitigation Review Group Meeting on March 10,1982.We would like to consider this version as final and ask your tnaulgence in any minor wording disagreements.If you have substantial problems with the policy,we will,of course,be glad to discuss them with you. The plan has been revised to include the following major points: 1.Goals of the mitigation plans will be specified in the plan and the goals considered in the modification and termination decision process. 2.It is the intent of the Power Authprity to negotiate directly and resolve conflicts with the resource agencies. 3.The responsibility for implementing the mitigation plans rest with the Power Authority. 4.The mitigation plans will be flexible to accommodate unexpected impacts or shifts in prioritization of mitigation of i~pacts. 5.Project modifications will be included as a mitigation option to be considered. 6.Alaskan agency involvement is more clearly defined. To simplify your review,the Jollowing sections and paragraphs have been changed from the version discussed at the March 10 meeting: 3:1 -Paragraph 1:The last sentence has been added. -Paragraph 2,Sentence 4:The words "ultimate"and "insuring"have been deleted. ACRES AMERICAN INCORPORATED C:l~!.uHii"~g i:r.gitif:e!$ The licf:rly ~cn~eJil:::;ng.!'..':2in at Court =l.:~'c;o.::ew vC"~~':202 r~ Fish and Wildlife Mitigation Policy Page 2 April 1,1982 - - - 3.3 -Paragraph 1,Sentence 1:The words "ultimate"and lIinsuring"have been delted. -Paragraph 2:This entire paragraph is new~ -Paragraph 3,Sentence 1:The phrase "an d to determine its effective- ness"has been added. 3.4 -Paragraph 2,Sentence 3:The phrase lithe Power Authority'has been deleted~ -Paragraph 2,Sentences 4 and 5:These entire sentences are new. -Paragraph 2,Sentence 7:The sentence has been revised and Sentence 8 added. 4 -Paragraph 3:The last two sentences are new. -Paragraph 5,Sentence 2:The phrase "including project modification" has been added. -Paragraph 5,Sentence 3:The second half of this sentence is new. -Paragraph 6,Sent~ence 2:The phrase "an d an explanation of those deemed infeasible"has been added. / -Paragraph 6,Sentences 4 and 5:These have been revised for clarity. -Paragraph 7:This has been moved from the original location of two paragraphs earlier.The last sentence is new. -Paragraph 10:The last three sentences are new. -Paragraph 11:This last paragraph has been revised to incorporate the issue of obtaining mitigation goals. Figure 1:Goals of Plan has been added to the first box. Originally initiated in January 1981,this policy is the culmination of a cooperative effort between the Power Authority,its consultants,and the natural resource agencies.This policy will serve as the foundation for further mitigation planning for the Susitna project. ACRES AMERICAN INCORPORATED Fish and Wild1~:€Mitigation Policy Page 3 Apri 1 I,1982 We sincerely appreciate your efforts in the reviews of the various drafts of this document ar,~your attendance and input to the mitigation meetings.We look forward to ~orking with you further on this very important aspect of the Susitna proj"£'ct.Agai n,thank you for your assi stance. Si ncere 1/, John D.lawrence Project Manager JDL:ah Enclosure cc:John Katz E.Yould ACRES AMERICAN INCORPORATED r~-- Letter #1 Mr.Al Carson Department of Natural Resources Pouch 7-005 .Anchorage,AK 99510 Mr.Bradley Smith Environmental Assessment Division· National Marine Fisheries Service Federal Building and U.S.Court House 101 C Street,Box 43 Anchorage,AK 99513 Mr.Michael Scott District Fisheries Biologist .. U.S.Bureau of Land Management 4700 East 72nd Street . Anchorage,AI<995~7 Mr.Gary St ackhouse· U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,AK 99503 Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Ms.Judi Schwartz Environmental·Evaluation Branch Mai I Stop 443 . U.S.-Environmental Protect jon Agency Region X 1200 Sixth Avenue· Seattle,WA 98101 Mr.Lenny Corin U.S.Fish and Wildlife Service 733 West Fourth Avenue Suite 101 Anchorage,AK 99501 r:,'I.'Ti rOt t"'.'.',",'.-Dt.,'.I l L:,j~i ~ Mr.Ronald O.Skoog, Alaska Department of P.O.Box 3-2000 Juneau,AK 99802 Conmissioner Fish and Game April 2,1982 P5700.11.70 1.1645 Dear Mr.Skoog:Susitna Hydroelectric Project Fish and Wildlife Mitigation Thank you for your letter of February 18,1982,commenting on the Susitna Hydroelectric Project Draft Analysis of Wildlife Mitigation Options and Draft Analysis of Fisheries Mitigation Options.We appreciate the time you and your staff have taken to respond to our request. A meeting was held with the Susitna Fish and Wildlife Mitigation Review GrouP-On March 10,1982,to discuss these wildlife mitigation options, proposed Phase II studies,and the revised Fish and Wildlife Mitigation Policy.Mr.Carl Yanagawa,Tom Arminski,and Karl Schneider of your agency attended that meeting.The Wildlife Mitigation Core Group,of which Karl Schneider is a member,met the following two days to formulate studies for Phase II,the purpose of these studies being both to quantify impacts and to plan for mitigation. The points raised in your letter of February 18 concerning the mitigation options and those raised in your letter of December 30,1982,concerning the Fish and Wildlife Mitigation Policy,were discussed at these meetings. The results of these meetings,particularly as they refer ~o the issues in your letter,were as follows: 1.A revised Fish and Wildlife Mitigation Policy,incorporating many of your agency and other agency comments,was discussed at the March 10 meeting.Agreement was reached on further changes;what will hope- fully be the final version of the policy will be circulated by April 15,1982. 2.Utilization of HEP and the issue of replacement lands was discussed at both meetings.No concensus of opinion materialized or final decision reached.It was agreed that some type of big game habitat analysis work would be conductea-in Phase II to complement the census and radio collaring studies conducted in Phase I and continuing into Phase II. It was also decided that one goal of this habitat analysis work would be to evaluate lands identified as potential replacement lands.The identification of these lands will be a Phase II task. ACRES AMERICAN INCORPORATED Con~ut1ing EnginE:erS Tr,e LibE:rly !!;lnk Bu,ld,ng Ph!in OIl Cour' Buffalo NE:,',York 1'202 C~t.er O"'Cl·~C~:~~!...r,l:J ...'l~L.ur!;h.PA,"":,,.'g',.lie ~':..,~.,r.wlC'l D_C '·"·"'-~'-·~.-·~:·T;T1r~':::'~-_...··---'--~-7-""----··-:':-.,----------c·-··------,---·-·---.0',',,-----,----__'._".''-__,_~__"__._.~__,,_.~._ Mr.Ronald O.Skoog Alaska Department of Fish and Game April 2,1982 - 2 .... "'"' 3.The issue of burning to provide moose habitat was also discussed at both meetings.It was decided the proposed BLM burn in the Al phabet Hills provides a unique opportunity for asse~sing the effectiveness of burning as a moose management tool in the Upper Susitna Basin,and as such,pre-and post-burning studies would be proposed as part of Phase II.These studies would,hopefully,provide the information to determine if this option should be further pursued.As you suggested, the Alaska DNR Plant Material Center staff was contacted by members of Terrestrial Environmental Specialists. I am enclosing,for your information,an Overview of Proposed ~hase II Wildlife ,and Vegetation Studies,which was prepared by the Wildlife Core Group,based on Phase I studies and input from the Fish and Wildlife Mitigation Revi ew Group.'This document was circul ated to the Mi tigation Review Group on March 19,1982.Detailed scopes,budgets,and schedules for these studies will be submitted to the Alaska Power Authority for their consideration. A clarification is requi~ed regarding the purpose and e~tent of the Fisheries Mitigation Options package submitted to your agency January 7, 1982.The intent of this document was to list the various fisheries impact issues that had been identified and to indicate the generic type of mitigation options that were being considered by the Fisheries Core Group. The purpose·in submitting the document to your agency,which is represented on the Fisheries Mitigation Review Group,was to supply some premeeting information so that your representative would at least have a feeling for the gener.al direction being pursued by the Mitigation Core Group. Considering much of the information on the fisheries resources and project design was not available until December 1981,the document submitted January 1,1982,was never intended to represent "an adequate assessment of the fisheries resources in the Susitna River or adequate evaluation of project impacts on that resource".We apol og i ze for the mi sunderstanding if your staff spent time reviewing the document under this context. Even without a complete assessment of the fisheries resources and complete evaluation of project impacts,we do consider that most,if not all, significant impact issues have been identified.In this context,pre- liminary mitigation planning is being pursued. Rather than responding to your specific comments on the Draft Fisheries Mitigation Options Package,I have enclosed updated documents on fisheries impact issues/mitigation options and a listing of fisheries question~and proposed studies.Both these documents were distributed to the Susitna Fish and Wildlife Review Group in early March 1982. The Fisheries Impact Issues and Mitigation Options Package was prepared by the Fisheries Mitigation Core Group.The purpose of the document is to identify key impact issues,'not to present a detailed impact analysis,.and to provide a discussion of tne-various mitigation options presently belng ACRES AMERICAN INCORPORATED --. I Mr.Ronald O.Skoog Alaska Department of Fish and Game April 2,1982 - 3 developed,not to provide a detailed assessment as to the suitability of the various options ..An impact assessment and draft mitigation plan are forthcoming,however,such are premature until further analysis can be completed. Thank you again for your time and that of your staff in reviewing these documents and attending meetings.It is very much appreciated.We are most anxious that the review process for the Susitna Project be as constructive and effective as possible.Ple~se ~o not hesitate to advise us of any difficulties or problems you may encounter in the fulfillment of our agency coordination program. Sincerely, Kevin R.Young Susitna Environmental Coordinator KRY:ccv Enclosures ACRES AMERICAN iNCORPORATED ALASKA POWER AUTli-rrORITY 334 WEST 5th AVENUE·ANCHORAGE,ALASKA 99501 Mr.Mike Small Bureau of Land Management P.O.Box 147 Glennallen,Alaska 99588 Dear Mr.Small: Phone:(907)277-7641 (907)276-0001 AprilS,1982 ,~ ..... Our efforts in mitigation planning for wildlife losses from the proposed Susitna Hydroelectric Project include exploring possibilities of habitat management in the upper Susitna basin.We have been advised by Karl Schneider of the Alaska Department of Fish and Game (ADF&G)and by our environmental consultants that your agency is planning an experimental burn of approximately 47,000 acres in the Alphabet Hills Region.We have been further advised that this burn provides an excellent opportunity to determine the effectiveness of burning in the upper basin as a habitat management tool,a subject on which little is currently known. Studies have been proposed to us by ADF&G and by our consultant to conduct both pre-and post-burn vegetation and moose surveys in this area.If the burn is to occur this summer,these studies must be conducted this spring. During the last meeting of the Susitna Fish and Wildlife Mitigation Review Group,Mr.Scott of your agency indicated the decision to proceed with the burn had not been reached and potential delays included the areas of burn plan and archaeological clearance. In the spirit of obtaining the best information possible on which to make mitigation decisions,the Power Authority would very much like the burn to proceed.We are prepared to make a substantial commitment of our resources to fund the studies proposed by ADF&G and our consultants.We are also willing to work cooperatively with BLM and provide whatever assistance we can. We must very shortly make decisions regarding the direction of the coming field season studies,including Mr.Mike Small April 5,1982 Page 2 spring studies in the proposed burn area.A timely decision from you or indication on how we may assist you would be greatly appreciated. If you wish to discuss this,please give me a call.Thank you very much. FOR THE EXECUTIVE DIRECTOR DDW/es cc:Mike Scott,BLM Mike Grubb,Acres i Karl Schneider,ADF&G s)jcer/rl?'fj~1JtP)J David D.woz~iak project Engideer Mr.John Rego U.S.Bureau of Land Management Anchorage District Office 4700 East 72 Avenue Anchor-age.AK 99507 Dear John: April 13.1982 P5700.11.75 T.1660 Susitna ~droe'ectric Project Mitigation Planning Thank you for meeting with me and Don Follows last week.-I appreciated your suggestions and input regarding the Suiitna ,reject mitigation efforts and how we may help to expedite the Alphabet Hills burn.I have been in contact with Mike Small and Jim Cbase to offer our assistance. Thanks again for your hel p and input into our studies. Sincerely. Michael Grubb Senior Scientist MG:ccv Mr.Carl Yanagawa Alaska Department of Fish and Game 333 Raspber~Road Anchorage.AK 99502 Dear Carl: Aprl1 12.1982 P5700.11.70 T.1650 Sus1tna I-\}tdroelectric Project Wildlffe Studfes Thank you for meeting wi th me last week.I am sure you and Tom are busy andsappreciated your time.Your suggestions were helpful and aid in the continued mitigation planning efforts for the Susitna Project. As discussed.I am enclosing a copy of the Overview of Proposed Phase II Wildlife and iegetation Studies.This document was dfstributed at the ~~rch 19.1982 Fish and Wildlife Mitigation Review Group Meeting. Thank you again for your time. Sfncerely. Michael Grubb Senior Scientist MG:ccv Enclosure April 13,lreZ P5700.11.74 1.1655 .1r.A1Carson Alaska Depart.."1ent of Natural Resources Pouch 7·005 Anchorage,Alaskll 99510 Dear Al:Susitna Hydroelectric Project ~.t1t1o~t1on Plann1nr Thank you for meeting with me last week and discussing your concerns regarding the Sus1tna project.I realize you hav~a busy schedule and app~ciated y~ur time. As I l1".antioned,I met last week with all tho mer.,bers of the fish and Wildlife ~~1t1gation Review Croup tncl rece1v2~valu~ble input anc suggestions. I look forward to ~~rk1n~furbher with you on m1t1~at1on plann1n9 for this project. Sincerely, f,91chael r.rubb Senior Scientist f1NG/jh April 13.19&2 P5100.l1.71 1.1657 Susftna t~droelectr1c Project Mft1Qatfon Plannin~ Hr.~.el Monson Acting Assistant Regional Director U.S.Fish and Wildlffe Service 1011 E.Tudor Road Anchorage.Alaska 99503 Dear Hr ••ionson: Thank you very much for arrang1n9 the moet1r.g with the members of your staff last week.I feel we are making progress in our mitigation planning efforts and look forwnrd to working further with the U.S. Fish and Wildlife Serv1cp on this 1rnpor~nt a$~cct of the Susftna project. TIlank you again for your holp. Sincerely. H1chael Grubb Senior Scientist NNG/jh - Mr.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,Alaska 99503 Dear Cary: ~.rrl1 ,~..1°e2 P57DO.ll.71 T.1659 Susitna Hydroelectric Project Piti9~tfon PilininQ ...., - Th3nk you for meeting with Don Follo\o!s and me last week;1 1 m sure you W!!n!busy reviewing the Feasibil1ty Report and t1f,prec1ated your time. Next tit'.£!we meet t\.'e can discuss ~ugar rr.'8ples,brcol~trout,Oickey- Lincoln.Seabrook,lobsters,Peldrim ihor.'pson and other ~o{\d Uew England topics.I'm looking forward to it. Sincerely, ,,"chae 1 Grubb Senior Scientist HHG/jh Mr.Lennie Corrin U.S.Fish and ~!lldl1fe Service 1011 East Tudor Road Anchorage,AK 99502 Dear Lennie: April 13,1982 P!700.11.71 T.1658 Susitna Hydroelectric Project Mitigation Planning Thank you for meeting with Don Follows and me last week.I realize you have Feasibility Report review responsibilities and appreciated your time. I feel we are makingpprogress in mitigation planning for the Susitna Project and look foniard to working further with you on this matter. Sincerely, r;f1 chael Grubb Senior Scientist MG:ccv Mr.Michael Scottu.s.Bureau of land ~'anagement 4700 East 72 Street Anchorage,AK 99507 Dear Mfke: Aprl1 13,1982 P5700.ll.75 T .1661 Sus1tna Hydroelectric Project Mitigation Planning - Thank you very much for meeting with me and Don Follows last week.I appreciate both your time and help in advising us on the Alphabet Hills burn.I have been in contact with Mike Small and Jim Chase and discussing what we can do to expedite matters. Thanks again. Sincerely, t·1ichael Grubb Senior Scientist MG:CCY LJ· -.;''"-' ~----------, April 21,1982 P5700.11.74 T1665 fT.Al Carson Department of Natural Resources Pouch 7-005 Anchorage,AK 99510 Susitna Hydroelectric Project Wildlife Mitigation Options Paper Dear Mr.Carson: Enclosed is one copy of the Susitna Hydroelectric Project Draft Wildlife Mitigation Option Paper.This document is part of the continuing process leading to a wildlife mitigation plan. Please review this paper.I will be contacting you shortly regarding a meeting to discuss this document. Thank you for your continued cooperation. Si ncerely, Michael Grubb Senior Scientist MG:m Enclosure cc:D.Wozniak,APA ACRES AMERICAN INCORPORATED Consulting Engin"e's The liberty e2nk 8~i'-;,~;t.~ain "t Court Bu~~c.do.Ne.o..Yorlt:,:202 .... .,... - -- Preceding Letter Sent To: Mr.Al Carson Department of Natural Resources Pouch 7-005 Anchorage~AK 99510 Mr.Bradley Smith Environmental Assessment Division National Marine Fisheries Service Federal Building and U.S.Court House 701 C Street~Box 43 Anchorage~AK 99513 Mr.Michael Scott District Fisheries Biologist U.S.Bureau of Land Management 4700 East 72nd Street Anchorage~AK 99507 Mr.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage~AK 99503 Mr.Carl Yanagawa Regional Supervisor for Habitat Division Alaska Department of Fish and Game 333 Raspberry Road Anchorage~AK 99502 Ms.Judi Schwarz Environmental Evaluation Branch Mail Stop 443 U.S.Environmental Protection Agency Regi on X 1200 Sixth Avenue Seattle~WA 98101 Mr.Lenny Cori n U.S.Fish and Wildlife Service 733 West Fourth Avenue Suite 101 Anchorage~AK 99501 April 26,1982 P5700.11.91 Tl680 Ms.Judi Schwarz Environmental Evaluation Branch Mail Stop 443 U.S.Environmental Protection Agency Region X 1200 Sixth Avenue Seattle,WA 98101 Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting Dear Ms.Schwarz: You are invited to attend the next meeting of the Susitna Hydroelectric Fish and Wildlife Mitigation Review Group,to be held at 8:30 a.m.,May 17,1982, in Room C121 at the Federal Building,6th and C Street,Anchorage,Alaska. The purpose of this meeting will be to discuss the Draft Wildlife Mitigation Options Paper mailed to you on April 21,1982.Please review this document prior to the meeting. Thank you for your time and input. Sincerely, Mi chae 1 Grubb Senior Scientist cc:D.Wozniak,APA ACRES AMERICAN INCORPORATED Cc.ns;..:::.ng Engi~,e-ers 1·_·~·._..~_•.(.~;,_j.-~r·~~e:JF, LJ - April 26,1982 P5700.11.91 T1682 - - ,.... Mr.Bradley Smith Environmental Assessment Division National Marine Fisheries Service Federal BUilding and U.S.Court House 701 C Street,Box 43 Anchorages AK 99513 Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting Dear Mr.Smith: You are invited to attend the next meeting of the Susitna Hydroelectric Fish and Wildlife Mitigation Review Group,to be held at 8:30 a.m.,May 17,1982, in Room C121 at the Federal Building,6th and C Street,Anchorages Alaska. The purpose of this meeting will be to discuss the Draft Wildlife Mitigation Options Paper mailed to you on April 21,1982.Please review this document prior to the meeting. Thank you for your time and input. Sincerely, Michael Grubb Senior Scientist cc:D.Wozniak s APA ACRES AMERICAN INCORPORATED Consuiling Engineers 'Th~li::~r:J'E.r:n~.Bu,'~:c;'''':t:g_~r/t:in at Court ?;j"c:lo t;e-~·.yo,....'7,~20,2 ~,.,.r::..;.,I...-:"4'",.",~""::( ..,~;-"r:.:,.....I :;t •~~:~::i"~:lr.iIr'.II~l:"~,"~ Mr.Michael Scott District Fisheries Biologist U.S.Bureau of Land Management 4700 East 72nd Street Anchorage,AK 99507 Dear Mr.Scott: April 26,1982 P5700.11.75 T1681 Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting You are invited to attend the next meeting of the Susitna Hydroelectric Fish and Wildlife Mitigation Review Group,to be held at 8:30 a.m.,May 17,1982, in Room C121 at the Federal Building,6th and C Street,Anchorage,Alaska. The purpose of this meeting will be to discuss the Draft Wildlife Mitigatior Options Paper mailed to you on April 21,1982.Please review this document prior to the meeting. Thank you for your time and input. Sincerely, Michael Grubb Seni or Sc i ent i st cc:D.Wozniak,APA ACRES AMERICAN INCORPORATED Con~ulli'lg ELgineers Th~Liberty Ba~k Budc,ng r~·.~:(at C~utl ec·..·.:0.t~!:,·.Yo·~1:2')2 April 26,1982 P5700.11.74 Tl679 - .- - ..... -- .... -, ..- Mr.Al Carson Alaska Department of Natural Resources Pouch 7-005 Anchorage,AK 99510 Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting Dear'Mr.Carson: You are invited to attend the next meeting of the Susitna Hydroelectric Fish and Wildlife Mitigation Review Group,to be held at 8:30 a.m.,May 17,1982, in Room C121 at the Federal Building,6th and C Street,Anchorage,Al aska. " The purpose of this meeting will be to discuss the Draft Wildlife Mitigation Options Paper mailed to you on April 21,1982.Please review this document prior to the meeting • Thank you for your time and input. Sincerely, Michael Grubb Senior Scientist cc:D.Wozniak,APA ACRES AMERICAN INCORPORATED Con~ul:ing Engineers Tr,e Liberty Bank Building.1M:,.,at Court 2u r:..IO Ne.·..Yor~14202 , T,:".!.'1·f.(;<j 1-eRES eUF April 27 t 1982 P5700.11.70 T..1684 Mr.Carl Yanugawa Regional Supervisor for Habitat 01vis1on Alaska Department,of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Dear tarl:Susttna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting You are invited to attend the next meeting of the Susftna Hydroelectric Fish and Wildlife Mitigation Revfew Group,to be held at 8:30 a •••• May 17 fn Room CIZ1 at th!Federal Buildtng,6th and C Street,Anchor- age.The purpose of this meeting will be to d1scussthe Draft Wild- life M1t'gation Options Paper mailed to you on April 21.1982.Please review this document prior to the meeting. The issue of quantification of habftat loss will be discussed at a workshop on May 18.This workshop will be attended by members of the Susftna Wildlffe Core Group and,because of the nature of the subject, the U.S.Fish and Wildlife Service.Mr.Karl Schneider of your agency. a member of the core group,wfll attend.I have asked him to contact you regarding other members of ADF&G who may wish to attend.To keep the meeting to a workable size.1 have asked Karl to limit the number of ADF&G attendees to three. I look forward to seeing you on the 11th. Sincerely. Michael Grubb Senior Sc1ent1st MG:db cc:D.Wozniak.APA E.Reed,TES - - .... MINUTES OF May 13,1982 Fisheries Mitigation Review Group The meeting of the Fisheries Mitigation Review Group was held at the Acres American Incorporated conference room on May 13,1982.Or.John Hayden,Deputy Project Manager for the Susitna Hydroelectric,called the meeting to order at 9:00 A.M.Those in attendance were: Mr.Al Carson,Alaska Department of Natural Resources Mr.Carl yanagawa,Habitat Divison,Alaska Department of fish and Game Mr.Ken Florey,Commercial Fish [)::ivision,A.D.F and Game Mr.Tom Trent,Susitna Hydro Aquatic Studies,.A.D.L and Game Mr.Mike Scott,Fisheries Biologist,Bureau of Land Management District Office Mr.Gary Stackhouse,U.S.Fish and Wildlife,Land and Water Department Mr.Bill Wilson,Arctic Environmental Information and Data Center Mr.Larry Moulton,Woodward-Clyde Mr.Allen Bingham,Susitna Hydro Aquatic Studies,A.D.F.and Game Mr.Christopher Estes,Susitna Hydro Aquatic Studies,A.D.F.and Game Dr.Dana Schmidt,Susi tna Hydro Aquati c Studi es,A.D.F.and Game Dr~John Hayden,ACFe.s·American Incorporated Mr.Don Foll ows,Acres American Incorporated Those absent were: Mr.Brad Smith,National Marine Fisherie's Service Mr.Lennie Corin,U.S.Fish and Wildlife Service Mr.Paul Krasnowski,Fisheries Rehabilitation 'Enhancement Development. A.D.E.and Game PURPOSE The meeting was called by Dr.John Hayden to review the recent developments in the management and organizational changes prompted by the need to refocus disciplines towards a more productive and cooperative approach of the common goals envisioned.Basically,the attached organizational chart strives for improved coordination of the integrated studies required for FERC licensing by separating primary responsibilities for scientific investigation and data collections (pure science)from the management and time constraints imposed by the Acres 'American Incorporated on behalf of the Alaska Power Authority.The new organizational approach strives to allow more "flexibility in designing critical data collection programs required by the aquatic studies team while providing objectivity through the data analysis and impact assessments component.This portion of the program will be integrated through the close working relationship of ADF&Game Arctic Environmental Information and Data Center.Working hand-in-hand,this interrelated team will still meet critical production milestones in the project schedule,but should be less pressured by the mitigation planning and Exhibit E preparation deadlines. To strive for improved data flow and professional integrity,the September 30th milestone for FERC license application is being relaxed.Negotiations are still underway by Acres American Incorporated in the selection of the ~ubcontractor to direct the mitigation planning.This entity will be announced when the final selection is made. PROBLEM As with any project that deals with the diversity of resource and distance from the vari ous subcontractors~Acres Ameri can Incorporated has suffered from poor communications and a rumor mill that operates quicker ~han actual management decisions. In a sincere attempt to correct this situation,Dr.John Hayden is personally moving his family to Anchorage,Alaska~for closer contact with the environment program and any potential problems that may need addressing.Additionally,Acres American Incorporated has been actively seeking to strengthen the environmental team by employing companies with previous Alaska experience. By streamlining the chain of command and personal interactions,it is hoped that the overall effort will become more product'i ve and posi tive in its approach to the tremendous task ahead.In dealing with personnel problems,an attempt has been made to save individual e~pertise by encouraging the best placement of the position within the overall framework for professional contribution. ••••••••f~we..1\\-n~ConstY/.llnts """ ..... ORGANIZATION MAY \3.1~8l FISHERIES A IQs~t1 R""eY AuttOVI~~__A cy~s Awaccicr.n Inco"rov.ft.J ERlC You\.o ~...:aI_PRIME CONTRACTOR Oy.~ohn H4~deY\ I,..'r--o....----..L..-'-_ 10m TYe.'tit Bill Wilson UN~NOyJN ? 5uat~:H;~vO AS.I----=~~AErO.c.~...FERC-E')(HIBIT E DATA CoUECnON DATAAlfAlv51S '-MlTIf.ATJON PLANs :J:f'1AtT ASSESS Time...Man4't~fnt ConstvQints Because the process deals essentially with a variety of agency policy mandates,both environmentally protective and regulatory in nature, agency representatives have sensed some frustration in providing professional input which goes beyond the administrative norms of the normal review process.Yet the common bond created by this awareness and the sincere efforts already contributed to the process are highly complimented. Working together to mitigate environmental concerns within a truly, unique State resource,while under the umbrella of social,economic, and political realities,requires the full sensitivities and dedication of all involved. DISCUSSION In the previous meeting,held on April 20,1982,in the Acres American Incorporated conference room,Dr.Dana Schmidt presented an excellent paper on the proposed fisheries approach and mitigation plan.Since then,Dr.Schmidt has decided his best input will be as a working member of the Susitna Hydro Aquatic Studies team.He resigned from Acres American Incorporated on May 3.Comments on the paper,either formally or informally,will still be received by Dr.Hayden It is hoped that they can be sent in by Fri day,Hay 21st. In a related management decision,Mr.Woody Trihey has submitted his resignation from the company.His plans are still unknown at this . time and the status of his fine instream flow work remains in question. As a vital component of the fishery mitigation plan,'instream flow work will continue in one form or another. Recently Dr.Hayden and others attended a FERC workshop in Washington D.C.to discuss the work and informally set the parameters for the studies required.Such discussion was very helpful.Based on the uncertainty of the full field season ahead and the viewpoint of resource agencies,a recommendation is now being formulated for transmittal to the Al askaPower Authori ty Board whi ch will rel ax the September submission date for license application. Acres American in now in the process of pulling together a new fisheries team (reflected in the organizational chart)to address anticipated needs and to maximize benefits from the coming summer field season. - - - To dispel local rumors that Acres American Incorporated automatically has the right to continue work on the next design and engineering phase of the project,Dr.Hayden pointed out:in response to the questions, that a Request for Qualifications for the next phase of the project was released by-the Power Authority on May 11,1982.Acres American will compete with other firms who have the full expertise in a large project of this nature.Selection of the next prime contractor will probably take place this fall.This Pahse II Contract will run from the fall of 1982 to the time that the power is on line.Our company will strive to maintain the continuity of the environmental program so that undue disruption will not take place during changeovers.Acres would hope to stay involved with the pursuit of the FERC license application .. While most of the other environmental studies will wind down·in scope~ the ffsberfes and wildl ife.programs .wi.l1 basically continue towards an acceptable mitigation plan which can be implemented prior to reservoir filling~Low.er levels of involvement will be required in the environmental subtasks as the project moves from the larger baseline studies to specific applications of the mitigation plans. Mr.Al Carson encouraged the continuation of the Susitna Steering Committee as a mechanism to advise the Alaska Power Authority.Their function could be to review and comment on the plans.Hopefully,the steering committee~operating from a higher level of authority,could contribute directly to project decisions.A memorandum to the Alaska Power Authority has been sent out for consideration. Mr.Tom Trent expressed his past concerns over the "gray"area of responsiblity which he fel t had not been adequately defi.ned between subcontractors when it came to addressing fishery data analysis and impact assessments in the past phase.This is an important area of concern.The products need to be defined.Pure data collection alone is not enough.Close coordination with the A.E.l~~.C.will be required to structure these products in a mutually acceptable mode. Mr.Ken Florey suggested that the previous pattern of review groups, mitigation groups~core teams and what all tended to confuse members F'" as to what their roles actually were. Without a better understanding of the interrelationships of all these groups and exactly what part each contributes to the overall process~ the individual becomes lost in the process.This is an excellent point from the perspective of the prime contractor,who may have encouraged more agency input than what could be realistically achieved.The suggestion was made by the group to focus on the idea for a Steering Committee to advise the A.P.A.at the higher level and to rely on the present Fisheries Mitigation Group for the remainder of the input.Therefore, only two review groups would be needed in the future. Bill Wilson recognized the need to work closely with the Susitna Hydro Aquatic Studies so as to provide one dynamic organization working from two overlapping boxes of .responsibility.This will require teamwork and constant interplay.Bill also expects to add some ~dditional expertise to his team at A.E.I.D.C.~ The group discussed various funding problems which are becoming a daily concern.Mr.Trent mentio~ed that his team has anticipated needs and is ready to run~when and if~the [loney is approprtated.Mr.Carson encouraged everyone.to flesh out the work program at various funding levels so that when funding levels are known,the manager will h'ave an immediate program response.The idea is to IIhit the street running." In summary,the mitigation review group felt that Acres American Incorporat~d has recently reached more of the Jllistening ll mode of response and that they see an end to the two year period of basic frustration.Mr.Carson expressed his belief that recently he has personally observed a change in attitudes.Hopefully,the group can take that new creation of a positive attitude about the project and carry it forward to its fruitful comp letion.~li1y throug1J s.ucll posit f..ve·efforts can the evvfronmental concerns of the project reach their achiev~ble goals. Next week,Dr.Hayden will meet with Tom Trent to scope out the activities of .the Susitna Hydro Aquatic Studies for this coming Held season. The group adjourned at 10:50 a.m. Respectively submitted: Donald S.Follows,Acres American Incorporated MINUTES OF MEETING May 24,1982-held at the Federal Building P5700.13.30 with the Bureau of Land Management Anchorage,on Friday,May 21,1982 I"""SUSITNA HYDROELECTRIC PRQ1ECT BLM Burn ,.,.. PRESENT: ~,J.McMullen )TES,Inc.f-Reed ) L.Byrne )BLM -GlennallenM.Small ) L.Buoy ) ,-.M.See )BLM -State Office D.Taylor ) K.Rowdabaugh )BLM -Anchorage District R.Fleming )APA,-S.Fancy )LGL Alaska J .McKendrick )University of Alaska..... M.Grubb )Acres The purpose of the meeting was to discuss BLM's proposed Alphabet Hills Burn and coordinate Susitna studies with BLM studies. BLM views this as a management burn,not a research burn.The objective is to kill off the spruce and produce browse for wintering moose.Weather -conditions required are 6-7 days of warm weather after August 15.The DEAR is not yet completed,but Michael Small foresees no problem. BLM will be establishing transects and collect pre-and post-burn data.The data will be species composition and percent cover along each 100 meter long transect.Dr.Verick,from USFS Institute of Northern Forests,will also be collecting vegetation data and measuring fire intensity.- Dr.McKendrick (University of Alaska)outlinedAhis study which is to deter- mine total vegetation response with browse as a priority item.He will """monitor soil nutrient response and measure fire intensity at the sample sites.Sampling will be at 15 vegetation sites including 5 outside the burn area.Biomass will be measured by life forms (browse,forbs,etc.).Photos for the area have been ordered,and mapping will be done at a 1:24,000 scale. A meeting will be arranged for BLM/INF/University of Alaska to coordinate location of study plots and data collection. BlM requested a letter of agreement be drawn up between BlM and the Power Authority.This should,basically,state who is doing what,where and why, what information will be available,and what support will be provided.This should be sent to Michael Small.For support,BLM requests: 1.Twenty hours of helicopter time before mid-July for cultural resource personnel.. 2.Helicopter support for vegetation studies.It is believed this can be done concurrently with helicopter support required by University of Alaska people.., 3.Helicopter support (approximately two 100 mile round trips by a 206 to sling load and install a weather station between June 15 and July 1). Michael Small will provide Michael Grubb with a list of BlM approved heli- copter contractors.Michael Small will also supply a copy of the BLM DEIS relating to mining,settlement options for BlM land south of the Alaska range,and east of the Parks Highway. Reported by :)?'1 ~ M.Grubb MG:ccv ALASKA POWER AUTHORITfU N25 1982 334 WEST 5th AVENUE -ANCHORAGE,ALASKA 99501 Phone:(907)277-7641 {907)276-0001 June 22,1982 Si ncere ly, ~r;~~Ld~ Environmental Analyst J Subject:Draft Memorandum of Under- standing Alphabet Hills Burn Thank you for your input during our telephone conversation on June 16,1982.I have included your suggestions on the revised draft of the Memorandum of Understanding (MOV).We shoul d proceed to have the MOU executed as rapidly as possible,so that studies can get underway. If the MOU is adequate,please initiate its being executed.If you have any questions or comments,please contact Richard Fleming at (907)277-7641. fOR THE EXECUTIVE DIRECTOR ~~!aChment:As noted. :z ~l:l:i ...IoOt:ii <C ,'~0 ~~IE-~<I)~<,~0 i JOG t 1 VTS .J w ~ IfiRH I--~HJ,-- ""'"CIRI -FMA,--....APA "-_. wee I 1"""-1---TES:t=, -R&M I ADFtoG,~~IBUFF!$G .....COL.I 'L',AU,~::·"peWER AUlI:GRITY "_SLSll_~J:~ FILE P[ff'11 .1Mr.Mike Small S~QUENCE NO,I'Bureau of Land Management I r11 t,1I P.O.Box 147 Glennallen,Alaska 99588 ,"".. tcc:~John Hayden ,Acres.Anchorage Karl Schneider,AK Dept~-6f Fish &Game Jay McKendrick,Agricultural Experiment Station .- ..... ALASKA POWER AUTHORITY MEMORANDUM OF UNDERSTANDING BETWEEN THE ALASKA POWER AUTHORITY AND THE U.S.BUREAU OF LAND MANAGEMENT PERTAINING TO COOPERATIVE INVESTIGATIONS OF THE PROPOSED ALPHABET HILLS BURN PROJECT WHEREAS,the Alaska Power Authority was established to reduce consumer power costs and otherwise to encourage the long-term economic growth of the state,including the development of its natural resources,through the establ ishment of power projects;and WHEREAS,the proposed Susitna Hydroelectric Project will affect existing terrestrial wildlife habitat by flooding portions of the Upper Susitna Basin;and WHEREAS,the Alaska Power Authority is committed to mitigating to the extent possible this loss of wildlife habitat;and WHEREAS,the use of fire through controlled burning may be an applicable management tool for mitigating habitat loss by improving habitat on other lands;and WHEREAS,the effectiveness of burning as a management too'l is not fully understood for areas similar to the Upper Susitna Basin;and WHEREAS,the U.S.Bureau of Land Management is planning a burn in the Alphabet Hills Region of Alaska; NOW BE IT RESOLVED THAT it is in the best interest of the State for the Alaska Power Authority and the U.S.Bureau of Land Management to cooperate in determ-ining the nature and magnitude of the effects on soils,vegetation,and wildlife which occur as the result of the burn in the Alphabet Hills so that the effectiveness of burning as a management technique can be determi ned,thereby ai di ng in the development of a wi 1dl i fe mitigation plan for the Susitna Hydroelectric Project; AND THEREFORE,it is the purpose of the Alaska Power Authority and the U.S.Bureau of Land Management to enter into this agreement, to wit: 1.The Alaska Power Authority and its contractors and the u.S.Bureau of Land Management will work together to monitor the effectiveness of fire as a method of managing habitat in the Alphabet Hills area.These studies address the use of large scale controlled burns for the management of wildlife habitat. - -, - 2.The Alaska Power Authority will provide helicopter support to the U.S.Bureau of Land Management for the purpose of studying vegetation and cultural resources in the Alphabet Hills burn study area and for establishing a weather station.This helicopter support shall not exceed 40 hours for U.S.Bureau of Land Management personnel only.The company supplying the helicopter and pilot will be subject to the U.S.Bureau of Land Management approval. 3.The U.S.Bureau of Land Management will initiate a burn in the Alphabet Hills region during August,1982.If weather or operati ona 1 constra ints prevent a successful burn during August,1982~then the Bureau will attempt the burn in August~1983,provided appropriate conditions occur.A successful burn shell be defined as one that includes at least 25%of the presampled vegetation plots. 4.The U.S.Bureau of land Management will allow personnel of the Alaska Power Authority and its subcontractors to conduct vegetation,soil,and wildlife studies on the land owned and managed by the U.S.Bureau of Land Management in the burn study area. 5.All data collected by the Alaska Power Authority and its contractors in the course of moni tori ng the effects of the burn will be available to the U.S.Bureau of land Management.All data collected by the U.S.Bureau of Land Management in the course of monitoring the effects of the burn will be available to the Alaska Power Authority and its contractors. 6.The terms of this agreement do'not relieve either agency from its legislated responsibilities. 7.This agreement may be amended at any time or terminated by either of the parties following forty-five (45)days written notification or within a lesser period by mutual consent of both parties. -- Eric P.Youla Executive Director Alaska Power Authority Date u.s.Bureau of Land Management Date Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting Date:May 17,1982 Attendees:See Attached List Held at Federal Building,Anchorage May 25 t 1982 The purpose of the meeting was to discuss the April 1982 Draft Wildlife Mitigation option paper prepared by TES.Comments were as follows: 1.The best way to determine brown bear response to new roads will be expert opinion.(USFWS) 2.FERC has changed EIS format to include alternatives Exhibit E requirements not changed.APA should get most recent FERC ElS.(APA) 3.Money spent for clearing may be better spent elsewhere. Is this considered a mitigation cost?(USFWS) 4.The option of no recreation or designation of the area as a wilderness should be considered a mitigation option.This would reduce or avoid many of the access-caused impacts.(USFWS) 5.ADF&G asked for policy on access,will they favor consumptive use?Agencies should express their opinion on what they want done.(APA) 6.Some type of matrix should be developed for trade-off of re- creation use \IS wilderness and other considerations.(APA) 7.Peregrine falcon issue will require official correspondence with USFWS.Contact a Dennis Money at Ecological Services.(USFWS) 8.Bald Eagle nests in reservoir area may be protected by Bald Eagle Act.Mitigation plan should include what integration has occurred with fisheries study.Will there be a reservoir fi s hery?(US FWS) 9.We should look at Ashetna-Tyone area as mitigation land areas; also along Denali Highway.(USFWS) 10.Mineral closures and other zoning laws may be used to protect replacement lands without having to manage.(ADF&G) 11.Issue of predator-moose-burning issue was discussed.If burn for moose who are impacted by bears then why mitigate for bears? 12.An artificial lick should be established prior to inundation to acclimate sheep to use it.Could water levels be manipulated to preserve the lick?(ADF&G-USFWS) 13.Agreement should be reached from all agencies on proper pro- tection to take for new caribou calving ground before it is established.This would include prevention of mining,settling, ORV use,etc.There should be a contingency plan for all sec- tions.(USFWS) - Page 2 14.APA should determine what BLM and ADNR are planning to do with land in Denali access route area.This also relates to land repl acement and caribou land repl acement bill.(APA) 15.Entire issue of construction camp configuration,operating mode and rail use road access was again discussed.These should not be accepted as givens in the mitigation options but scenarios presented which would avoid impacts.Example -flying people in and out daily instead of construction camps,etc.Then show if it is not cost effective.(USFWS) 16.For safety of people and dogs,dogs should not be allowed in camp.(USFWS): 17.It is important restrictions are enforced (speed limits,ORVIs, etc.). 18.Type 2 impacts:It was requested that justification should be presented as to why dropping pool elevation cannot be done. Should be presented as a mitigation option then dismissed if economics shows it.(USFWS). 19.Option of creating flooding every 10-15 years by opening flood gates was discussed.This would be to simulate natural flooding. However,would wipe out fishery mitigation.USFWS sees no problem with downstream vegetation changes but wants information to sub- stanti ate it. 20.Transmission line mitigation lacking in mitigation plan.Needs to be beefed up. 21.Research station should be considered only as low priority;only for compensation. MMG:dlp NAME Mi chae 1 Grubb Tom Arminski Richard Fl eming Don Follows Joe McMullen Ed Reed Leonard P.Corin Gary Stackhouse David D.Wozniak ATTENDEES May 17,1982 REPRESENTING Acres American ADF&G APA Acres American TES TES USFWS USFWS APA A+-k~~ ____M ~-'t-J.l--j .t !_.~.._. }"."'---.-.._. --------------_._-----_._._------ iM I e-'~br vb!:'Ac Y~J---~----_.-'--'-'---'_._'--~"-------'._----~-----------~----_.----~--_._--------~-------.------ -7:;;kJ-~~~i~~L~k)=_-----------------.----_Al)_£f_~------_--_ -~-~\C-l~_~\.~~.~~1--------~------.fi p 6.-__-;---- -~~~_____d~~__~---- ___.j~£_lJ5ttq~"-~p ..~E5./-/;,c.~---------- ""'"/3:,/,,,(l I -.;7 6s ~ ---------.,-~------_-----_--.-.__---_---____-_-I ---__-------- .',\~c~,..-':":1<',l-<:'.\,.J:..:[',1-..---r ~.--,.--'-=----.-'-----------..-,------_.-----~---.-'-'----..-------.- -:)."-.J OJ_~/_~-__:~_10:_1i.KA..);.x:;:~_ '0&\""l b .J)WO?.,J tM<... ____.\.A~,~~'~_~~_ t!5FtJ S ~.,: =..~,-...L ~":__ Mr ..Lenny Corin U.S.Fish and Wildlife Ser~ice 733 West 4th Avenue Suite 101 Anchorage,Alaska 99501 Dear Mr.Corin: June 1 p 1982 P5700.11 ..71 Tl726 Susitna ,Hydroe 1ectri c Project Wildlife Mitigation Planning Thank you for attending the May 18th meeting to discuss the objectives and general approach for a terrestrial habitat evaluation system for the Susitna project. Due to the change in environmental consultants,we have not yet formalized a plan for further development of this system.We will be contacting you shortly and ask for your patience in this matter. Thank you again for your input. 5i ncerely, Michael Grubb Senior Scientist MG/jk cc:R.Fleming,APA ACRES AMERICAN INCORPORATED CGrisu:ting Er.gineers The LibeV"t}'Ba!:~:'5l..;L:.r.g.r.~c:~n 2t Court EU~~;'!:J r'ei.Yc r ...~'::2:2 r '......r .'j'r..~, -Preceeding Letter Sent To: - """ J~ Mr 1 Lenny Cori n U.S.Fish and Wildlife Service 733 West 4th Avenue Anchorage,AK 99501 Mr.Greg Konkel U.s.fish and Wildlife Service 1011 East Tudor Road Anchorage,AK 99503 Ms.Ann Rappaport U.S.fish and Wildlife Service 733 West 4th Avenue Anchorage,AK 99501 Mr.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road. Anchorage,AK 99502 Mr.Kark Schneider Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 (0:--~ - I \.\..;. .....- /JA r s.HAMMOND.GOVERNOR , I DEP.'\RT ."E~T 0.'....ISII .-\:"il)G.-\.1It:I! OFfICE OF THE COMMISSIONER / July 27,1982 P.O.sox 3·2000 JUNEAU.ALASKA 99802 PHONE: i"'l Eel:I __~o..J ,"',- Mr.Eric Yould Executive Director Alaska Power Authority 334 West Fifth Avenue Anchorage,Alaska 99501 Dear Mr.Yould: ~The Alaska Department of Fish and Game has been involved with the Mitigation Review Group in attempting to formulate a workplan that would eventually arrive at mitigative solutions to probable adverse impacts to fish,wildlife and their habitat resulting from the Susitna Hydroelectric project.Internally,my Department is also analyzing an array of mitigation options that may be acceptable if they are demonstrated to be workable and satisfy the Department1s mandate to mitigate adverse impacts.The following is a list of options,that we hope the Alaska Power Authority is considering as part of their mitigation planning. I must emphasize that these are by no means the only options that should be considered.In addition,because environmental studies to assess impacts of the proposed project are incomplete and specific mitigation plans have not been identified,these suggested mitigation options either indiVidually or collectively may not satisfy the.requirements of this Department.However,we believe that they should be evaluated now so that data regarding feasibility and desirability are available when project impacts have been quantified. By evaluating these mitigation options concurrently with ongoing impact assessment studies,we believe that considerable time will be saved in completing the permitting and licensing process. 1.Fisheries a.Instream flows required to maintain present populations of fi sh below the two dams shoul d be carefully evaluated. Included in this evaluation should be an array of flow regimes that~when considered with the anticipated loss of fish habitat associated with each,cou1d be a basis for further mitigation measures.The areas immedfately below the dam sites,as well as areas further downstream, should be included.Temperature regimes should also be Eric Yould -2-July 27,1982 .... evaluated concurrently with stream flews.These ev~luations should be made on construction as well as operational temperature and flow regimes. u.If it appears that onsite mitigation of fisheries impacts cannot be accomplished,hatcheries should be considered. Locations of possible hatchery sites should be identified in accordance with my Department's policies on artificial production of fish.My Department1s Fisheries Rehabilitation Enhancement and Development (FREO)staff has considerable expertise in selecting sites and designing hatcheries in coordination with other Divisions of my Department.I \'Iould suggest that the FRED Division be contracted immediately to do the site evaluations.A specific proposal is enclosed. c.My Department has been funded by the Legislature to study the salmon enhancement potential of the upper Susitna River without respect to the project.In the case where mitigation of fisheries impacts cannot be.mitigated within the project area,enhancement of the Upper Susitna system may present a viable option.Results from this stUdy will be made available to you and should be included in the array of options for mitigation. 2.Hildlife c.Habitat enhancement options for wildlife species should be evaluated.For example,habitat manipulation to enhance moose browse could be considered in areas where present habitat is considered low in productivity."Thi s option would need to consider the long-term effectiveness of the project,since moose browse is only available at early successional stages. b.Replacement lands should be considered as another option. Lands outside the development area (preferably adjacent to the development)should be identified and possibly set aside by legislative designation for the purpose of mitigating wildlife habitat losses from the project • This option may be the most viable option for wildlife. 3.Both Fish and Wi ldl ife !.Impacts from construction and maintenance of the transmission and road corridors should also be evaluated. As I have stated previously,the above list is to be used in developing a total mitigation package and is transmitted for that purpose. The following briefly sumnarizes my Oepartment1s hierarchial approach to implementation of mitigation (mitigation policy enclosed): Eric Yould -3-July 27,1982 1.Avoiding the impact altogether by not taking a certain action or parts of an action; 2.Minimizing impacts by limiting the degree or magnitude of the action or its implementation; 3.Rectifying the impact by repairing,rehabilitating,or restoring the affected environment;, 4.Reducing or eliminating the impact over time by preservation and maintenance operations during the life of the action;and 5.Compensating for the impact by replacing or providing substitute resources or environments. If you have any questions,please feel free to contact me. Sincerely, Enclosures (2) Alaska.Depar'tment of Fish &Game F.R.E.D.Division PROJECT PROPOSAL I.Title:Susitua River Hatchery Site Investigation .....II•Description: r 1.Objective:Identify locations of possible hatchery sites in the vicinicy of the Susicna River. 2.Ti.me£rame:July 1,1982 -June 30,1984 - -- III.Justification:If the Susitna Hydroelectric Project is determined to have a negative impact on existing salmon p01'ula.tious in the Susit:na Uver,various lI1e&Sures may be employed to mitigate this 1m1'act.A fisb hatchery is an option that caul.d be used to supplement or replace uaturalproduction.'!he potential for successfully employing this o1'tion depends on the species of salmouinvolved and.the availabUicy of good hatchery sites. A.critical step in the planning pha.se of develo1'ing a fish hatchery is the systematic and careful selection of an appropriate site.'!he key factor,of course,is to find a 10 catiou with a reliable and adequate water·supply.In addi.tion,this water supply should be located where logistical problems can be minimized.Broodstocks must be identified and developed. Strategies for production releases mast be considered and the management of returning stocks must be biologically sound. Since the selecti011 process for a hatchery site is,perhaps,the most critical step in the development of a successful hatchery,it is important to collect thoroagh mddetailed information.This process requires at least CWo years.During the first year,a large number and a wide variety of sites w:Ul be screened and the most likely candidate sites will be selected.During the second year,these primary sites will be investigated UlOre intensively-. IV.Methods and Procedures: A.First year:During the first year of the hatchery site selection survey,a large number of systemS will be surveyed and categorized to assess their value as a possible hatchery site.Ini.tially,ADF&G files will be examined and discussions held 'Jith other study groups to determi.ue which systems will be surveyed.Available data will be evaluated and daca needs will be .ident:i.tt8d.Field surveys ~-:i.ll then .be lDDbil.i%ed t:o collect the pettittent infomation so that the best candidates can be selected for further studies.Data co be collected 'Jill include:wa.cer source,size of t:he wacer source,water teuqJeratures,thorough water chemist1:Y.land status. engJf.neering analys:is.fish stocks preset,logistics,basic management considerations,and potential broodstocka.A minimum af one field survey will be conducted at each potential site.By the end of the first year of the survey, the Eour most likely hatchery sites will be identified. During the second year of this hatchery site selection survey, the most likely hatchery site candidates will be studied more thoroughly.They will be monitored much more frequently or continuously.It is particularly important to determine the ~eliability and predictability of the water supply,the water temperature,and the water chemistry.The suitability for construction will be analyzed.The size,location,and availability of particular broodstocks will be ~erified. Stocking strategies will bee determined and the most likely management schemes for returning adults will be developed. By the end of the second year,the best site will have been identified.Approximate costs and a preliminary development schedule will be provided.The potential for successfully producing the ~arious species will be analyzed and recommendations given on alternati~es to explore should a hatchery not appear to be a feasible method for replacing expected losses of a particular species. v.Personnel: A.Project Leader:Fishery Biologist IV,F.R.E.D Di~ision. B.Schedule: Fishery Biologist tv Fishery Biologist III Fishery Technician III Engineer First Year Second Year 4 man months 4 man months 7 man months 8 man ll10nths 3 man months 5 man ll10nths 2 man months 4 man months First Year Second Year 21,000 21,000 37,700 43,200 7,700 12,800 9,700 19,500 VI.Cost: ·Line 100 Salaries:FB IV FB III FT III Engineer CE II Line 200 Travel &per diem Line 300 Air charter - fixed wing.$180/hr x 25 hrs $500/hr x 10 hrs 500 4,500 5,000 x 30 hrs x 14 hrs 600 5,400 7,000 Line 300 cont. Vehicle m:i.leage 800 900 Vehicle rental 1,000 l,OOO Telephone and photoco~y 500 500 Photo processing ZOO ZOO J~W'at:er analysis Z,500 4,000 Line 400 Scientific s~pplies (e.g.chemi.c:al.s )ZOO 300 Film 100 100 Gasoli.ne (outboard)100 100 Supplies 600 800 Line 500 Mon:Ltoring equipment 3,000-TOTALS:92.1 120.1 AU\SXA DEPARTMENT OF FISH AND GAME STATEMENT OF POLICY ON MITIGAT!ON OF F!SH AND GAME HABITAT OISRUPTIONS Prepared March 1982 .... ALASKA DEPARTMENT OF FISH AND GAME Statement of Policy an Mitigation of Fish and Game Habitat Disruptions I.The ~eed for Policy Logging,construction,mining,agriculture,and other developmental industries r which use land'or watar are of great importance.to many Al askans.When """'properly pursued,these undertakings can be compatible with proper management and iJse of Alaska I s val uab 1e fi sh and game resources.However,improper practices can lead to significant degradation of the State l s fisheries and game resources through alteration or destruction of important habitat components. .,.., 1'fl1&n Oevelopment includes a multitude of practices such as road building,bridge construction,culvert placing,excavation,dredging,.clearing,dragging, dumping,and other activities.At issue ;s 1and and water,the very bases of all development and all fish and wildl ife habitat.Each development action requi res space,and thereby a1ters fi sh and game hab i tat and compromises other types of uses.Oevelopment activities,when disruptive to fish or wildlife resources,may,for 'example,increase erosion or sedimentation,divert, obstruct,alter,or pollute water flow,aggravate temperature extremes,alter and destroy populations of animals and vegetation,reduce food supplies, restrict movement of fish and game,disturb or destroy spawning,nesting'and breeding areas,cnange adjacent or downstream habitats,or change the capacity of a stream or wetland to store and use stenn or fiood wateM. Often,such habitat losses are inevitable and little can be done to prevent or control them.,but often they can,in the publ ic interest,be abated or limit;gated."The avera 11 mit;gative goal of the Department of Fi sh and Game is to maintain or establish an ecosystem ~the project in place that is as nearly desirable as the ecosystem that would have been there in the absence of that project.The decision levels through which a project is reviewed - preventing,minimizing,and replacing ecosystems -is outlined and discussed in t&,i s pol i cy ~ The magnitude of devel opmenta 1 inf1 uencas on fi sh and game habi tat is to a large extent dependent on the ~~9rse·to which developmen-t operations and facil ities and land or water use projects are properly pl anne<!and upon the .~,.. consc,ent,ous adhe~nce topracti ces des i gned to protect fi sheri es and wi 1d- life values.Therefore,it is the primary objective of the Department of Fish and Game that fish,game and habitat values be prominently considered by developers and regulatory agencies prior to development or issuance of regula- I tory approvals.Consideration should take place during the planning and implementation of land or water associated development to avoid or minimize foreseeable or potential adverse environmental effects before the fact of damage,and early enough to consi der benef;ci al alternatives.Simi 1arly,it is imperative to provide for repair,restoration,or rehabilitation of habitat damage after it occurs,should it occur at a 11,as well as maintenance of the reconstructed habitat over time.However,.it is appropriate that this option of after-the-factredress assume a second priority status to mitigation planning before the fact of damage. These concepts--preventing,minimizing,replacing~hen lmolded into a worting definition of mitigation,will contribute to the sustained functioning of aquatic and terrestrial systems,and thecont1nued viability of common -I -i property fi sh and game resources,'Nhi 1e pravi cling for the ather ne~.js of Alaskans arising from beneficial publ ic land and water use programs.A mitigation policy,therefore,is essential to ouide,~~,development actions by insuring considerations of alternatives to or in land and water conversi ons and to fu 1fi 11 the sustained yi e 1d management precepts of Alaska law. II.Authori ty The Department's basic responsibility as a conservation.agency derives from the Conmissioner's a.uthority to manage,prote~t.,maintain,improve,and extend fish,game,and aquatic pl ant T"T!sources of the state ~AS 16.05.020).This Statute,in combination with constitutional direi:tives,provides implicit direction for the Department to offset losses to fish,wildlife,and their habitat.. The Department1s responsibility to impose mitigation measures also derives from the same laws which authorize it to issue written approvals (permits)fa~ land or water use.programs.In each instance the developer must obtain the Department's approvaT .as the sufficiency Of the developer's plans to provide fer free passage of fish (AS 16.05.840),or provide,proper protection to fish and game when conducting projei:ts in anadromous fish streams (AS 16.05.870), State game refuges (AS 16.20.060),State game sanctuaries (AS 16.20.1Z0),the natural habitat of endangered species (AS 10.20.185),fish and game critical habitat areas (AS 16.20.260),and State range areas (AS 16.20.300-320). -3- Simultaneously,a strong basis for prescr~bing mitigation lies in the public trust doctrine.In simple tenns,this doctrine,founded in common law, asserts the pub 1i CiS ri ght to unimpaired use of pub 1i c 1ands and waters for fish and wildlife production.The Department,as trustee for the public,is obligated to protect'that right.The public trust doctrine t~us provides additional'ability as wen as an obl igation to be,rigorous in mitigating disruptions to public fish and wildlife resources.including their habitat. III.Statement of Policy A.Definition The directive to mitigate is clear.The nature of and extent to which mitigation is camed out is left to the Department I s discretion.In considering mitigatory options it is essential'to recognize the differing degrees of stress that may be placed on natural fish and wildlife habitat.Lightly-stressed aquatic or terrestrial systems adjust to change,and recovery tak.es pl ace through natural processes when the· stress is removed.In contrast,a heavily or overstressed natural system cannot"restore itself to original conditions through natur-al processes alone.In this case,the system's capacity for maintenanc~and repair has been impeded,and at this point man must provide assistance for the system to be restored.These differences in recovery potentials dictate different p~iority approaches to implementing mitigation measures. Accordingly,the Department of Fish and Game,when administering miti- gation measures oursuant to its permit authority under AS 16,embraces .... - """ (1)avo;di ng the impact altogether by not taki ng a carta;n acti on or 'parts of an action; (Z)minimizing impacts by 1imiting the de9ree or magnitude of the action or its implementation; (3)'rectifying tne inrpact by repa;ring,rehabilitating,or restoring the affecte<t env;ronment; (4)reducing or elimin:ating the impact over time by preservation and maintenance operations during the life of the action; (5)compensating for the impac~by replacing or providing substitute resources or environments • .8.Imolementation rne Department will implement the five'fonns of mitigation punuant to its statutory authof1ty in the following manner~ 1.Mitigation to Avoid or Minimize Habitat Damage -~- a.Avoi dance The Oepartmentls primary approach to mitigation is one of ore'lentive ccnservati on desi gned to avo;d an e'lershri nki ng base of natural habitats and costly man-~ssisted restoration efforts.It;~founded on preventi ng adverse,predi ctab 1e,and i rreversib 1e trends or cnanges in natural aquatic or terrestrial systems.rne objective is to maintain as much existing natural habitat as possible,even if the relative importance or interrelationships of living organisms are not riA 11 y known.Apa rt from denyi ng outri ght the issuance of a permrit,this can be accomplished by attaching stipulations or conditions to permits for proposed developments.Discretion at the field level is required to allow tailoring of various developmental activities to sites and times for maintenance of individual or groups of fish and game species and various habitats used annually or seasonally.Mitigation by permit stipulation can be employed to avoid activities in areas with a high risk of adverse impact,such as nest sites,wi.nter ranges,or critical habitat.Development consistent with the objectives for designated areas can proceed according to the stipulations or conditions.rnis fundamental approach provides for beneficial land and water use programs in natura1 systems. b.Minimization This concept differs from avoidance in that it is acknowledge?that some habitat damage will occur.The Oepartmen~recognizes that land - i~ and wate:-deve 1opment proj ects are mandated by pub 1ic need, legislative or constitutional prioritization or land use,or pervading economic considerations.It is recognized that industrial,agricultural and residential development in Alaska will cause some amount of habitat destruction,and t~at this damage has~ been accepted by developers and pol icy makers as the pri ce of economnc benefit.The second priority mitigative approach to habitat management is to make that loss less severe,or to minimize foresee~ble disMJptions to aquatic and terrestrial systems.The focus of this approach is to maintain habitat diversity and the capacity of each system to restore itself naturally from stress or' damaqe,while accomnodating preemptive uses o~land and waters frequented by fish and wildlife -uses which may reduce species abundance to some degree or cause some di sturbance .to natura.! species behavior. Minimal adverse habitat disruption may be-achieved by permrit stipulati-ons which 1 imit development actions when and where necessary and to the extent needed to maximnze conservation of fish and wildlife values.For example"temporal mitigation measures·, which involve adjusting the timing of project activities to reduce impacts in areas of high risk,cah be used to restrict development to the seasons when the impact is least,or to reduce the amount of time spent in a sensitive·area.Habitat.may be stressed t!!lJ1:'orarily,but recovery can take place through no-cost natural processes. -7. 2.~itigation In ·Lieu of Habitat Damage a.Rectification ThE!'third priority mitigative approach is to reoair,rehabilitate, or restore'abused aquatic or terrestrial,systems.This requires onsite or post-construction evaluations of water and land developments after"the fact of damage,or estimation,during the p1anni ng stage t of Tike1y envi ronmenta 1 damage.Recti fi ca ti on is less desirable than avoidance or minimization because,even if restoration is complete,there is a net loss of fish and wildl ife reSCUM:e and habitat resulting from the time lag between the impact and full replacement.Such time lags may vary mm days to decades. Thus,gains or benefits to be real ized fT"OM thi s fonn of miti gation are somewhat less than those of full prevent1 on. The objective is to restore the same functions as those that were lost.,or,to restore the habitat to pre-disturbance conditions. However,if the factor restricting the number of a species.using an area is also limited further by the development,it makes litt.le sense to devise and implement factoM which cannot al1eviate that ~ituation.Additionally,the simplistic view of maximizing one kind of habitat at the expense of another should be avoided.The Department recognizes that there will be situations where no rehabilitation of the loss incurred is possible. -8- ,- - -I ..... If proper pl anning occurT"ed and recti fi cation was not considered necessary,rectification should only be necessary when the developer has,not complied 'N'ith his plan,applicable laws,permit stipulations.Rectification of disruptions to habitat may be implemented through permit stipulations and amendments or imposed as a court ordered penal ty.It is likely that.many completed or partially completed projects can be retrofitted wi'th feasible restoration requirements that could result in the reeoverJ of substantial ·amounts of project-caused fish and wildlife losses. b.Preservation and Maintenance Actions Mitigation should be recognized as a cont.inuing obligation, inextricably tied to a project and carried out during the entire life of the project.The Department recognizes that if mitigation measures are approved but not ooerated and maintained during the life of the project,little or no mitigation,which may have helped justify the project in the first place,wil'be realized.The Department holds to the principle that costs of mitigation are all nannal costs of any land or water.development project 'and must be' borne by the develop~rs and beneficiaries of the project• Preservation and maintenance operations may be imposed through permit stipulations or amendments to permits.For example,drainage structures installed An fish streams should be required to be---. ~intained properly;and erosion must be corrected when it occurs. Re.veqetated areas wbi ch are not successful,for whatever reason; -9- must be revegetated until they have become established.In these ways,adverse impacts will be reduced or eliminated over time. A requirement (or pennit stipulation)tha't developers continue to mitigate by maintenance operations during the life of the project wi 11 ensure tnat consenati on objectives.are me;;and 1 iti gat;an is avoided. c.Compensation ~henever a project will cause a reduction or loss of values to the public-losses in tenns of fish and wildlife populations or habitat,. recreati on opportuni ti es,access,and other foregone resou rca use" opportunities--the project sponsor must create or restore an equi- valent part of the aquatic or terrestrial ecosystem'to comcensate for the loss.The most di ffi cu 1t prob 1em encountered wi th th is approach is detenni n;ng what kind of act;on is appropriate and how much mitigation is adequate.The problem can be resolved qua1ita- tively,throuah neaotiation and quantitatively through the estab 1i shment of eva 1uati on procedures. It is the Oe~artmentls position that co~ensation should not involve a simple payment of dollars,but instead should involve replacement of lost habitat,populations or recreational opportunities. Compensation by replacing or providing substitute resources or environments is the least desirable fom ofmitigati"on because it -10- - - - accepts loss of habitat at the outset and and often cannot result in total reparation for those losses.When it must be implemented y however,the preferred form of compensation is onsite mitigation; that i.s,all damage caused by a project should be replaced within th~development site or project area where damage occurs.ihe same functions as an!-lost should be directly restorefi;replaced,or co~ensated..Only secondarily should compensation by substitution, or trade-off of.an unavoidable 'ecel ogica I 1ossfor an ecel ogica 1 improvement el sewhere,be.used.Trade-offs or conversi ens only change one kind of'envtronment for another,and may be desirable or not,depending upon the viewpoint considered.There are diver9~nt views'and interests.between 1oca 1 and more di stant'users regartiing the value of the ecological Ilimprovement ll to the natural system that was already in place • .Any type of compensation wi 11 be costly,and the values of lost reSOUM:es cannot be measured solely through economic cost/benefit ratios or man-day evaluations.This sort of analysis must be accompanied by evaluations which measure factors other than human uses of land,water ,and the resources within.The value of the intardependent biological relationships within an entire ecosystem is too often ignored.Since some ecosystems,such as wetlands,may never be successfully replaced or substituted,it is important that the land owner,developer,and the various g~vernment agencies WQ~ together to salvage such lands to.rectify the loss of the resouree values of those areas.The Department recognizes,however,that in _11_ some rare cases,the only compensation negotiable may be prevention of future losses in another or adjacent area. c.The Role of Plannina Proper mitigatiolT of fish and game habitat los~es requires that land and water use projects be properly designed and planned.This requires basic decisions by field personnel at the earliest project conceptualization or design state,before permits are issued. Proper planning,particularly at the area or re9ional level.will assist in abating a conman cause of fish and wildl ife habitat decline,that of piecemeal habita~losses which cumulate from sequential projects. R29;onal or area planning,when it prece<1es significant land or water use programs,will allow reduction of the cumulative effects resulting from a variety of projects. Prior to permit issuance there should be a realistic assessment of the specific ,·'osses which likely will be incurred~rne losses should be i dent;fi ad fi rst in terms of lost resources and second 1v in terms of the uses which may be foreqone.This is because human use and resource productivity do not always correlate.The Department cannot accept analyses which equate low human use figures to low estimates of losses. Low human use has no bearing on how much fish,wildl ife,o·r their habitat may have been 1ast;or how much productivity,biol ag;cal diversity or eM ti cal procasses were impai red.However.the 1ass of .human use should be a factor that will need to be mitigated. -12 .. - - - ..... ~, "... Losses of fish and wildl ite habitat that cannot be mitigated will affect the peocle who utilize those resources.~Jherever the carrying capacity of the land or water is reduced,harvest of species by subsistence, commercial,and reereational users may have to be reduced.Recreational opportunities to view resources may also deeline.As the population of the State of Alaska increases,competi,tion for fish and game resources will surely increase.Oecreased abundance of these resources will mean that some resource users will get less of the resource than they may have had in the past.·As more and more habitat is damaged or lost,the prob 1em of a growing popu 1a ti on base and its pressure on fi sh and wildlife,will be aggravated. The impacts of a proposed project and alternatives'to it on all the natural resources affected,therefore,should be assessed early in the project pl anning process.The effects of a·project on other resources, such as timber or water,and human use should be assessed,as well as the direct effect on fish and wildlife.Nonstructural alternatives,e.g., providing minimum stream flows rather than a hatchery to maintain a'. population of fish,for achieving the project.objective should be required and censideredfil"'St since these ceul d be expected to have the least negative impact on the abil ity of the project area to provide natural resource val ues. Including consideration of all natural resources eatly in the planning process shou 1d 1ead to deve10pment of ways to !IIi nimi ze effects on tt1ese. resourees in all phases of pro~ect development and reduce the nee<!to later add on the more costly,canspicuous,and less desirabl!!remedies after the fact of damage.rne specific p~pert;es and characteristics ~f the natural system which must remain after development should be defined prior to initial permit issuance.The developer is then al10wed to proceed with the project under pre-established mitigation measures,which will guarantee functioning of a natural system and not cause permanent or costly public harm. o.Assessment of Dama~es The combination of population pressures,diminishing space,energy needs, and the necessity of considering economic variables in most decisions tlave all culminated in questions regarding the intrinsic values of man1s surroundings.Attempting to place price tags on an area1s worth,whether .. in t~rms of its retention as a natural system or its value in an altered condition,is inherently difficult. The state of the art in habitat valuation will lag behind the need to make permit decisions.The Department holds that fish and wildlife habitat should be preserved unless the expected benefits of the develop- ment is demonstrably 111arge ll relative to loss of fish and wildlife values.Of course,what is deemed acceptable must be a broad social decision which necessarily "requires assessment of the resource damage 1ikely to be incun-e<i as a result of the development. lit theory,it would seem a simple matter to ob$erve the impact of a. construction IJr1]ject,determine if fish or wildlife are killed,and then assess damage.In practice,it is anything but.Damage may be -14- - ..... incremental,and not identifiable without extensive basel in~and post- project data.Mortality may affect juveniies as well as adults.Damage to habitat or to populations of juveniles may not impact resource users or be measurable for several years hence when particular species should have reachett adulthood.Other damages,such as tho~e affecting migratory species or the lower elements of a marine food chain,may be visiole but nat ~enable to markat place valuation.Less tangible aspects of resource damage include decreased aesthetic worth and decreased ability to provide a:specific wildlife habitat.Finally,in an environment possessing many,often only partially understood,natural interrelation- ships -and impacted by any number of man-M!lated activities -definitive assessment of preci sa cause and effect re 1ationshi ps •between ~eve 1opment impacts and fish or wildlife ,mortalities will be difficult and often impossible. This problem is intensifie<i by the absence of even rodimentary data at a large number of site-specific locations.It follows that assessment of damage will,at best,be a combination of assessment of the partial data base available concerning stock levels,seasonal and cyclical abundance and location,together with a scientific judgement of the "most 1ikelyll resu 1t of envi ",nmenta 1 damage,based on a genera 1 understand;ng of fi sh and wildlife habitat dependencies and tolerances. These type$of judgements put extreme pressure on fi sh and wi 1dl i fa scientists and pose unknown ri slc.s for the resource.In sudl cases,and where the only other alternative is to stand mute and observe a steady erosion of fish and wildlife values -uncorrecta~and uucompensated for - a judgement decision is necessa~J. The Department holds that the appropriate standard for measuring damages to natural resources is the cost which would be reasonably incurM!tt by the State to restore or rehabilitate the environment in the affected area, to its pre~xist;ng condition,or as close thereto as is feasible without grossly disproportionate expenditures. The question is prompted:at what point do indirect or cumul ative effects become so remote-that mitigation should not be require<t1 The Department recognizes the IIwithout-the-projec~basel ine assumption fol'" resource eva'luation purposes when imposing mitigation measures.It is from tni s basel ine that the degree of project impact,and hence the degree of mitigation required,may be measured. Because damage estimates will be based upon scanty or incomplete knowledge,and will often be p1"'Obabilistic in nature,it is possible that estimates of limost likeli'level of damage may,from time to time,vary. It is this Department I s bel iet that in such cases of difference,the onus of proof to explain any lower estimates must lie with the developer. Thi·s position is based upon the recognition that the develop~r is the potential beneficiary of both an ea.rly start (relative to time required fol'"adequate environmental inventory)and of any lower damage estimate that is put forth. IV.Sumuary -16- - - , .(1 )Mitigation is necessary to guide development in order to preclude,abate, repa i r,or ;ndemni fy the adverse effects upon fi sh,game,and thei r habitat resulting from development projec~s in fish streams and in refuges,sanctuaries,critical habitats,and the natural habitat of endangered species. - ..... - - (2)Department's authority to approve development plans in streams and special areas,as well as the public trJst doctrine asserting the public's right to uni1l1l'aired fish and game production on pUblic lands, provide the means and the obligation to compel mitigation measures. (3)Differences in recovery potentials due.tedi fferi ng'degrees of stress placed upon fish,game,and their habitat dictate that mitigation measures be selected accordingly. (4 )Mitigation before the fact"of damaqe is the preferred means ,with avoidance of damage as the primary objective,and minimization rectificati on,maintenance,and compensati on foll owjng ;n that order. Each may be implemented through permit stipulations. (5).Mitigation measures imposed after the fact of damage or in 1ieu of , expected damage,may require n!ctification of damage,maintenance of con-ecti ons over ti me,or compensati On by rep 1ad ng or substi tuti ng. reSOUM:es or envi ronments. (6)Rectification,necessary only when the permittee has not fulfilled his obligation,may be iD1l'osed by.permit stipulation or by court ordered -17- penalty.Projects may be ro:trofitted \1~th feasible r-:s'toration r-:quiro:- ments to recover fish.game.and habitat lasses. (7)·Maintenance mitigation actions are project r-:lated.rne Department holds that maintenance mitigation costs are.nonnal development costs to be borne by the developer and project beneficiaries.This form of mitigation may be impose<i by pennit stipulations or later amendment. (8)Co~ensation by providing substitute resources or envi ronments is the least desirable form of mitigation.When impose<i it preferably should be impremented onsite rather than by "improving l'an existing ecosystem elsewhere.Compensatory mitigation will only be implemented by negotia- ting a written agreement with the developer. (9)Mitigation should be considere<i at the earliest project conceptualization or design stage.All impacts should be assessed early in the project planning process with first consideration given'to nonstructural alterna- tives to the project objective. (1.0)Fish and wildlife habitat should be p1'"f!served unless the public benefit of the project is demonstrably lartJe.Assessment of damages will be a Department .decision base<i in part on existing data bases and in part on Ilmost~1 1 ikely judge.rnents. (11)The burden of proof to justify lower estimates of damage to fi sh and wildlife habitat lies with the developer. - September 2.1982 Mr.Ronald o.Skoog,Commissioner Department of Fish and Game P.O.Box 3-200 Juneau,Alaska 99802 .Dear eo.iss1onet Skoog:Susttna Hydroelectric Pro.1.!S1 During the second quarter of thts year,the Alaska Power AUthority circulated the draft Feasib1lfty Report on the Sus1tna ~droelectric Project and numerous supporting documents to State.Federal and local agencies with interests in the project.This circulation included virtually an of the data and analysis done to that date during the study.Currently.efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory COIIIliss10n in the first quarter of 1983. During the remaining time before fi11ng,the Sus1tna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project fmpacts.This effort will include requesting another review of the projects Environmental Report, which is the draft of the FERC license application Exhibit E,by your agency.we wilt be circulating the draft in mid-November of this year. After f111ng with Ind acceptance of the appHcatfOll by FERC.there will be another opportunity to.COIIIent Oft the application,including Exhibit E. At this time we are requesting that the reviewing agencies provide us with input to the mitigation planning whtch wl11 go into the draft of Exhibit E.Your letter of July 21,however.included the type of response regarding mitigation measures and preferences which we are proceeding to solicit fro.other agencies. I appreciate the timely guidance which your Department has provided to the SU5itna project planning effort.We will be responding to your recOIlIJIendations and cCRDents by further correspondence in the draft Exhibit E. SePtelllber Z.19'. CoRI1Ssioner Ronald O.Skoog 'age 2 Tour continued support and efforts in the study of the Sus1tna~droelectr1c Project are appreciated. Sincerely. SIGNED Ene P.Yould Executive-Director E"%l1b CC:Mr.J.Hayden Mr.C.Yanagawa Mr.J.Schneider Mr.T.Trent Mr.T.Al"Ilinsk1 DI:PARTJlENT 0 ........ISH ."NO GAJlt: OFRCE OF THE COMMISSIONER P.O.BOX 3·2000 JUNEA U,ALASKA 99802 PHONE:465-4100 - October 15,1982 Mr.Eric Yould Executive Director Alaska Power Authority 334 West Fifth Avenue Anchorage,AK 99501 Dear Mr.Yould: OCT 221982 At SKIt f'v~'.\U•..~1"THO,':'IT't - - - - RE:Mitigation ·The Susitna Hydroelectric Proj ect and other Alaska Power Authority projects may create conditions that would require changes in hunting, trapping,and fishing regulations.For example;improved access might redistribute harvest pressure in a manner that would tend to increase harvest levels.Such situations may require changes in seasons,bag limits,or methods and means to ensure that harvests are not excessive. APA will have to address these problems in its environmental assess- ments and mitigation plans.However,I need to point out that under State law the Board of Game and Board of Fisheries are the governmental bodies responsible for allocating the fish and wildlife resources by appropriate regulations.A strong feature of the State?s fish and game regulatory process is its ability to quickly respond to changes in population levels,user demand,and management objectives. Fish and wildlife management suffers when management actions are implemented through some less flexible authority such as statute, judicial order,or regulation or stipulations set by agencies not directly responsible for maintenance of fish and wildlife populations.It would be particularly inappropriate to commit the State to regulatory regimes to offset impacts that may not occur for several years.There is a substantial possibility that the impacts may not be as predicted or that populations or management objectives would have changed.Consequently,any plans or recommendations for mitigation that might require or suggest changes in fish and game regulations should be directed to the Boards of Fisheries and Game for their consideration. This procedure does not apply to restrictions placed on individuals brought into the area to engage in construction activities.It applies only to regulations affecting the general public.It is entirely appropriate for APA and its contractors to limit proj ect personnel.because construction projects create unusual concentrations Eric Yould 2 October 15,1982 of people brought into the area by means not available to the general public. In summary,APA still has a responsibility to attempt to avoid or minimize impacts first,and for those impacts that are unavoidable APA should seek alternative mitigation measures other than restrictive fish and game regulations.As longer term effects emerge,requiring adjustments in management controls,the only legal authority for regulatory response will be through Board action.As long as APA and the Department actively monitor these projects,the existing system should be adequately responsive. Sincerely, Ronald Skoog Commissioner - - - - .... september 2,1982 Mr.Robert McVey.D1 rector AlastaRegion National MlMne Fisheries 5en1ce P.O.Box 1668 Juneau,Alaska 99802 Dear Mr.McVey:Susitn.Hydroelectric Project. Dur1n~rtbesecondquarterof this year,the Alaska Power Authority circulated the draft Feasibility Report on the Susitna Hydroelectric- Project and numerous supporting,documents to State,Federal and local agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory C0IIIII1ssion in the first quarter of 1983. During the remaining time before f111ng,the SUsitna stUdy team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project illPacts.This effort will include requesting another review of the project·s Environ.ntal Report. which is the draft of the FERC license application Exhibit E.by your agency.We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC,there will be another opportunity to comment on the application.including ExhibitE.. At this time we would appreciate Iny input into the continued plan developgent you could provide.In particular,we request your guidance with regard to project impacts and the mitigation opportunities your agency would recommend.These cOIJIIlents will be helpful both in identi- fying and addressing the most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to address these cements in the draft,it would be IIIOst helpful to have them by the first ()f October. As you know.the planning process is dynamic.Current efforts are fOCUSed on project access.transmission corridors and project operation alternatives..Althcugll ttllS l'tf'l:rmat10n has not yet been distributed· for comment,it w111 be included in the Exh1b1t E drQft. ( September 2.U.__ Mr.Robert McVey Page 2 We welcome your comment on all arels of the project,but,in accordance with Section 4.41 of the FERC regulations,we are particular- ly interested in your CODIaents with regard to anadl'ORJOus fisheries.In these areas,we would like to address your concerns on potential impacts and lIit1gation measures which .can be included in project plans. Your continued support and participation in the development of the Sus1tna project license .pplication is greatly appreciated. Very truly yours,, SIGNED --Eric P.·Yould Executive Director EPY:mb cc:Mr.J.Hayden Mr.Brad 5m1tt. UNITED STATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration NationaZ Marine Fisheries Service P.o.Box 1668 Juneau,AZaska 99802 R E.;.,..;.'I E 0 October 15,1982 OCT 2 11982 - - Mr.Eric P.Yould Alaska Power Authority 334 West 5th Avenue Anchorage,Alaska 99501 Dear Mr.Yould: I have received your letter of September 2,1982,regarding the current status of the Susitna Hydroelectric Project Feasibility Studies.You have requested any input our agency may provide at this time,particu- larly with respect to project impacts and mitigative measures associated with anadromous fishery resources.Such consultation is specified by the FERC regulations for Major Unconstructed Projects,18 CFR Part 4. Realizing the latest schedule for preparation of the draft Exhibit E and submission of license application,I feel it is important to state or re-state the position of the National Marine Fisheries Service (NMFS)so that the license application may incorporate our views or respond to them as outlined in 33 CFR Part 4.4l{f}.This section specifies that the application must contain uA description of any measures or facili- ties recommended by State or Federal agencies for the mitigation of impacts on fish,wildlife and botanical resources." NMFS's primary concerns regarding the Susitna project include provision of adequate instream flow regimes for spawning,rearing,and migration of indigenous fish species;maintenance of water quality for these species;and provision for compensation of all resource damage in in- stances where such impacts cannot be mitigated.These concerns are discussed below.. 1.Flow Release J1.dequate flow regimes are critical for anadromous fish.Conse- quently,water flows for successful spawning,rearing,and migration must be established and maintained downstl~eam of the project area.If flow reduction or modification of flew regimes is anticipated in the operational scenario for this project,anadro- mous fisheries could be adversely affected within the entire Susitna Ri ver system downstream of the facil ity. To address these matters,flow studies must be performed to de- termine flow releases that will conserve and protect stocks of .anadromous fish in the Susitr.a River.Specific flow regime pro- posals based on studies and acceptable to NMFS must be submitted part of your license application.With regard to this issue,we are particularly concerned with the side channel/slough environ- ments of the T~lkeetna to Devil Canyon reach which appear to be particularly important to anadromous fish.Significant post project flow alterations will occur below Talkeetna during winter months,and the impact of these changes must also be addressed. II.Water Quality Adequate water quality is also essential to viable populations of anadromous fish.Several concerns exist with regard to water quality parameters that may be altered by the Susitna project, these include: A. B. C. D. E. Siltation and other construction related im acts:Construc- tion should proceed at times of east bio oglca activity and should employ best management practices to further reduce these impacts. Temperature changes:The license application must describe temperature changes related to project operation,discuss the impact such changes would present to fish,and propose miti- gation measures which will avoid or lessen such impacts.The applicant must also describe the specific studies,reservoir models,and riverine models upon which temperature projections are based. Dissolved gases elevation:Gas supersaturation may occur due to plunging water near dam sites and result in fish/gas-bubble disease.The license application should describe measures em- ployed to mitigate this impact;e.g.,cone valves. Turbidity changes:The application must describe,for the entire year,the effect of the project on glacial till suspended in the Susitna River water column. River morphology chanres:Altered flows and interruption of bedload transport cou d effect channel changes,perching of tributary confluences,and armoring of the streambed below the damsites.. III.Compensation for Unavoidable Losses Effective flow releases and water quality conditions are intended to avoid losses to existing and potential anadromcus fish re- sources. Despite maximum use of these mitigative measures,unavoidable damage to fish resources may occur either during or after construction.Compensation in the form of fish habitat improve- ments,artificial production or similar methods is required to fully replace such unavoidable loss.An initial plan which rec- ognizes contingencies such as unanticipated construction impacts - - - must be developed as part of your license application.SUbsequent refinements or modification of this plan may be necessary once the project begins operation and the success of mitigative measures has been assessed. Recognizing the proposed construction schedule for the Susitna project and the political,economic,and environmental concerns which may con- tinue to influence project development,it is likely that the project may operate as a one dam (i.e.,Watana)system for a considerable period of time.Therefore,the license application should identify and discuss those resources,impacts,and mitigative/compensative measures associ- ated with the construction and operation of the Watana Dam in the absence of the Devil Canyon Dam.NMFS will provide additional comments upon review of the 1982 Environmental Report and draft Exhibit E and in response to the FERC license application.In the interim,we are available to discuss any concerns you may have regarding the positions of our agency in this matter. Sincerely, ",~_.--:'""7 ./'\,/''//"'&-''<--t--;l-y-?-----" >'i/1~/j."....- r ......Robert W.McVey /'//Reg iona 1 Di rector The preceding letter was received.Responses are as follows: I.Flow Release The Alaska Power Authority recognizes the need for adequate flows to maintain fishery habitat.The flow releases proposed for the project were based on a compromise between "no impact ll flows and "maximum powEi!r"flows.Chapter 2 and 10 of Exhibit E explain the methodology and rationale of flow releases selected.Chapter 3 discusses the potential impacts to fish and mitigation plans to reduce these impacts. II.Water Quality A.Siltation and Other Construction Related Impacts Best management practies will be utilized to control siltation.These are discussed in the mitigation sections of Chapter 2 and 3 of Exhibit E. B.Temperature Changes All of the requested infonnation is presented in Chapter 2 and 3 of Exhi bit E. C.Dissolved Gases Elevation Gas supersaturation is not predicted to result from project operation. Fixed cone valves have been proposed.This subject is discussed in Sections 4.1 and 4.2 of Chapter 2 of Exhibit E.' D.Turbidity··Changes Seasonal impact analysis is discussed in Sections 4.1 and 4.2 of Chapter 2 of Exhibit E. ..- - E.River Morphology Changes This subject is addressed in Sections 4.1 and 4.2 of Chapter 2 of Exhibit Eo III.Compensation of Unavoidable Losses The mitigation plan in Chapter 3 of Exhibit E includes methods for fish habitat improvements and other methods to replace unavoidable loss.The mitigation planning process will continue . The Susitna Hydroelectric project has been studied and is proposed as a two-dam project.Thus,the license application addresses the impacts of two dams.Included is a discussion of impacts during the period when Watana is complete and Devil Canyon is not. Detailed comments from your agency will be addressed when received. September 2,1982 Mr.Ty D111iplane State House Preservation Officer Depa r1:IIent of Ra tural Resources Division of Parks 619 Warehouse Avenue.Suite 210 Anchorage,Alaska 99501 Dear Mr.D1111plane:Salitne Hydroelectric ProJect During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the Susitna Hydroelectric Project and numerous supporting documents to State,Federal Ind local agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study._Currently,effOrts are proceeding towards completing the first phase10f planning efforts and submitting a license application to the Federal Energy Regulatory C...i5510n in the fint quarter of 1983. During the remaining time before filtng.the Sus1tna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the project·s Environmental Report. which is the draft of the FERC license application Exhibit E,by your . agency.We will be circulating the draft in mid-November of this year. AFter fl1ing with and acceptance of the application by FER.C,there will be another opportunity to comment on the application,including Exhibit E. At this time we would appreciate any input into the continued plln development you could provide.In particular,we request your guidance with regard to project impacts and the mitigation opportunities your agency would recoanend.These COlllleftts will be helpful both in identi- fying and·addressing the IIIOst important areas of concern in the next draft Exhibit E and in docu.ent1ng agency·c~nts and recommendations before FERC.In order to address these cOIIIDents in the draft,it would be mast helpful to have them by thef1rst of October .. As you know,the plannfng process is dYnalll1c.CUrrent efforts are focused on project access,transmission corridors and prOject operation alternatives_Although this information has not yet been distributed for comment,it will be included in the Exhibit E drIft. ,.... 5epteD1ber2.Ii. Mr.Ty 81111plane 'age %*".-t......-. We welcome your counent on all areas of the project.but.in accordance with Section 4.41 of the FERC regulations,~are particular- ly interested in your comments with regard ,to historical and archeological resources.In these areas,we would like to address your concerns on potential impacts and mitigation measures whicb can be included in project plans.. Your continued support andpart1c1pat1on in the development of the SUsitoa project license application is greatly appreciated. Very truly yours. ~iGNED Eric P.Yould Executive Director EPY:mb cc:.",.J.Hayden· Mr.Alan carson DEPARDIElft'OF lV&nJIUL RESOI1ROW DIVISION tW PAMS October 15,1982 JAY S.HAMMOND,GOVERNOR 619 WAREHOUSE OR .•SUITE 27t, ANCHORAGE.ALASKA 99!J07 PHONE:27if.11676 REGE!VED OCT 2 11982· Re:1130-13 Mr.Eric P.Yould Executive Director Alaska Power Authority 334 W.5th Avenl.le Anchorage,Alaska 99~Ol Dear Mr.Yould: "'1 A \I1'Ht'\D'TVALASKAPO~J;.;,,-.".V,· Thank you for your letter of September 2 soliciting our recommendations on Susitna Hydro Project impacts and mitigation measures with respect to cultural resources. First of all,we wish to commend archaeologists Dr.E.James Dixon of the University Museum and Mr.Glenn Bacon of the Alaska Heritage Research Group, Inc.,for the excellent job they have been doing in locating cultural re- sources prior to ground disturbing activities. Preconstruction survey is,of course,the first s~ep in impact mitigation - the location and boundaries of cultural resource sites must be known.While this work is fairly far along,more needs to be done as plans become more concrete. Secondly,these cultural resource sites must be evaluated in terms of eligi- bility for inclusion in the National Register of Historic Places.For eval- uation,each site within the project area must be sufficiently investigated such that their boundaries,stratigraphy,relative age,cultural affiliation and potential to yield significant scientific information are known.Many of the currently known sites require further,more intensive,investigation for eligibility determinations to be made.Since so little is known about the prehistory of the area,each site discovered takes on added significance.In addition,groups of sites within a river drainage have been classic study areas throughout the history of anthropological archaeology.It would appear that a high percentage of the discovered sites may be eligible for the Na- tional Register. Thirdly,each eligible site must be examined in terms of "Effect."Will the proposed action have "no effect,""no adverse effect,"or an "adverse effect"? This would have to be done on a case by case basis.The criteria for deter- minations of effect may be found under Title 36,Code of Federal Regulations, Part 800. - ,~ - .... Mr.Eric P.Yould October 15,1982 Page 2 - Please note that every effort must be made to mitigate future It a dverse effecttl activities to National Register or eligible properties.In the few expected cases where very large,complex sites will be adversely effected,it may be more economical to build a barrier around the sites.In many cases,substan- tive investigation may be necessary.If so,this will usually mean relatively complete excavation ~f the site in order to recover as much scientific infor- mation as possible. These recommendations are essentially those suggested by Dixon,et aI,in the Cultural Resources Investigation Phase I Report (April 1982). We are confident that impacts to significant cultural resources will be fully mitigated throughout the course of the Susitna Hydroelectric Project. Sincerely, Judi th E.Marquez Director 0'((~~Z-r"~,-)-4 \:___(\'_._-l By:Ty L."Dilliplane . Stat:eHistoric Preservation-Officer cc:Ms.Leila Wise,DNa,A-95 Coordinat~r Dr.Edward Slatter,FERC Archaeologist Mr.Lou Wall,Advisory Council on Historic Preservation Dr.E.James Dixon,Lead Archaeologist,SusitDa Hydro Project Mr.Glenn Bacon,Lead Archaeologist,Alaska Heritage Research Group TS:c1k MEMORANDUM State of Alaska DEPARTMENT OF NATURAL RESOURCES DIVISION OF RESEARCH AND DEVELOPMENT TO:ERIC YOULD Executive Director Alaska Power Authority DATE: FILE NO: October 11,1982 276-2653 SUBJECT:Proposed Susitna Hydro Proj ect TELEPHONE NO: /'REEJ~l;~s Dirlctor FROM: ...\'J~O ~C~ P.~\~'Ot nr:'\'2.P-\"f'(VV ~1\\O.. y()¢\\ The Department of Natural R~es appreciates the opportunity to comment on project impacts on the proposed Susitna Hydropower Project and to recommend mitigation strategies.The department has cooperated with Alaska Power Authority (APA)on this proposed project during the last two years and refers the APA to earlier comments,specifically DNRts testimony on April 16,1982,to APAts Board of Directors (attached).The issues listed in DNRts testimony,water appropriations,instream flow reservations,and access to the project,continue to be major concerns.Additional comments are listed below.In some cases comments may repeat earlier DNR comments. As you are aware,the department is now in the process of preparing a regional land use plan in cooperation with the Matanuska-8usitna Borough which includes the lands surrounding the hydro project.This plan,which will be completed in 1983,will result in land use designations and land management policies for state and borough lands throughout the area. To date,the planning team responsible for developing this land usc plan has consciously avoided any direct involvement in Susitna Hydro issues,relying instead on the more detailed work being done by other individuals within DNR and DF&G.The planning process is now at a point where it makes more sense that there be closer coordination between the two projects,specifically in the two areas outlined below. 1)The planning team can review and comment on information regarding regional,indirect impacts of the plante.g.population growth, changes in resource demand,etc.). 2)The plan can be used as a tool·to guide use of pUblic lands to mitigate or control secondary impacts of the proposed project. I suggest that you designate a staff person to coordinate these two projects with Chris Beck (Susitna Plan project manager). As stated in DNRts recent comments on recreation planning,we are concerned that recreational facilities planned in conjunction with the hydropower proj ect may be under-utilized.A related concern is the h£grr cost to the state of maintaining potentially over-developed,under-used public recreation facilities. 02-001A(Rev.lO/791 Susitna Hydro Project -2-October 11,1982 ....The Division of Geological and Geophysical Survey has completed a detailed review of the soils and geology components of the feasibility study.Those comments (attached)are intended to be informal and for the consideration of APA and its contractors.Other geological and geophysical concerns are listed below. 1)Existing information indicates that glaciers in the project area are retreating;this and their seasonal nature may affect water availability. 2)The two large bodies of water created Qy the proposed project may affect the micro-climate of the area. 3)The dams,by blocking sediment travel,may increase erosion downstream. 4)There may be a substantial change in the area between the two dams over a period of time in response to changes in flow regime,the amount of sediment introduced and transported,and the hydraulic geometry of the valley (gradient,width~depth,discharge,and velocity of the channel). The department requests that any trees felled in the project be made available to the public and that commercial quantities of forest products be made available to the commercial community for harvest and utilization. Attachments cc:Chris Beck,DRD Leila Wise,DRD Al Carson,DRD RS:LW:lln MEMORANDUM TO FROM AL CARSON Deputy Director,DRD/DNR RANDALL UPDIKE Geologist V,DGGS State of Alaska Departma1t of Natll'al ResOlrces Division of Geological &Georhysical SIZVey DATE:4-26-82 FILE NO: TELEPHONE NO:688-3555 SUBJECT:Review of Susitna Hydro Feasibility Study I have been requested to review Volume II,Section 6,Soils and Geology of the Susitna Hydroelectric feasibility study,representing DGGS.My comments will sometimes refer to specific paragraphs within the section but are generally of a summary nature based upon the discussion of the entire section. To insure the long-tenn integrity of a high masonry dan such as those under consideration in the Susitna Hydroelectric Project,three fundamental issues of geotechnlcal siting must be addressed:(1)geologic foundation conditions at the damsite,(2)suitab"ility of the reservoir based upon the geologic interaction between the basin,stored water,and dam,and (3)seismic exposure of the system.My following discussion will be essentially limited to item (2) above which is the prime concern of Section 6.These comments are based upon the nine page summary that I was provided for review. We can identify five criteria which are essential,but complex,geologic variables in evaluating the suitability of a given terrain for reservoir development:(1)nature and vari abil ity of bedrock within,adj acent to,and beneath the proposed reservoir basin,(2)composition and distribution of unconsolidated deposits over bedrock within the basin,(3)basin geometry (including slope angles),(4)distribution and flow gradients of surface and ground waters within and adjacent to the basin,and (5)ambient stress fields with in and adj acent to the bas in. - - The overwhelming majority of hydroelectric darns in the \\()r1d have safely met and exceeded design specifications since construction.In fact,masonry dams have performed better than mQ;st manmade structures during earthquakes.However, catastrophies asso€i ated with dams and their reservoirs have occurred frequently enough to warrant our utmost concern.One of the most serious threats to the dam-rese.rvoir-basin systen is the potenti a1 for massive,high velocity 1 ands1 ides entering the reservoir.Such sl ides can propagate destructive surface waves which impinge on opposite shore1 ines and occasionally the dan itself.Such was the case of the Va.iont Dam,Italy,1963,when a 230 foot-high wave was generated by a sJide,leaving 2,600 dead and missing. 1.)Bedrock-related concerns. -The majority of great 1ands1 ides in recorded history have involved the slope fail ure of indurated sediments,or bedrock.These fai 1 ures typi ca lly occur along one or more discontinuities within the rock,which,for a variety of reasons,have shear stresses exceeding resisting frictional stresses.Discontinui't;ies are often p1 anal',and may be repeated in a subparallel manner through the rock body.In F some cases failure results from the intersection of t\\()or more sets of weakness -- planes.from the bedrock geology descriptions fo~the basins upstream from the two damsites I would 1i ke the following to be considered: l.A}MetamQrphic rocks are of concern due to the fonation and joint patterns which typically develop in such rock,as well as the mineral assemb1 age itself which often can be easily sheared,to,·further 1ubric-ate~failure planes (p.6-2,para.3). 1.B)Conjugate joi.nt sets typ.ical of intrusive rocks.(which are a1 so indkated to be present in the basins)can generate complex fail ure schemes (p.6-2,para.2;p.6-5,para.2). ,.... ,Susitna Hydro.Fe-easibi1ity Study Review Randall Updike Page 2 lC.)The contacts between rock units,for example those between the intrusive rocks and arg·i 11 ite-graywacke sequence,can serve as extensive pl anes of discontinuity (p.6-2,para.3;p.6-5,para.2). I.D}Although no active faults may be identified in or near the project area, numerous older inactive faults probably exist and,in conjunction with mylonitization along these zones,can provide additional planar trends for failure.Often,major river valleys follow regional fault trends with subsidiary faults paralleling the trend of the master fault.Thus,the subsidiary faults may tend to parallel the valley walls,enhancing the failure susceptability along these trends (p.6-5,para.3). ~In addition to planar discontinuities within mappable bedrock of the valley walls,concern should be expressed for bedrock structures "hidden" beneath the unconsolidated sediments in the valley floors.This would be of prime concern as reservoir filling proceeded,which induces profound physical stresses on the underlying rock masses,as well as imposing large hydraulic head values over a broad saturated "foot print"of the reservoir floor (p. 6-2,para.1;p.6-4,para.2). 2.)Unconsolidated sediments. Whereas bedrock failures usually occur as moving blocks or slabs,unconsolidated sediments (e.g.,soil,till,alluvium,colluvium)lack strong interparticle bonding and,therefore,are more susceptible to slope failure.Concerns I have, based upon the summary geologic report are: 2.A)Contacts (discontinuities)between unconsolidated sediments and underlying bedrock are usually abrupt,at high angles along valley walls,and saturated with groundwater (p.6-3,para.1;p.6-4,para.2-3). 2.8)Typically gl aci ally-rel ated sediments vary significantly in texture and degree of consolidation which can produce: Susitna Hydro Feasibility Study Review Randall Updike Page 3 ..... 2.B.1)Underconso1idated (soft)sediments below grade (p.6-4,para.2) 2.B.2)Seismically liquefiable sands and silts (p.6-7,para.1) 2.B.3)Textural discontinuities which can act as failure planes (p.6-4, para.2-3) 2.B.4)Confined aquifers having substantial hydraulic head 2.C)Old landslides were identified in the report.Often such slides are in equilibrium with existing conditions which can be dramatically modified by reservoir water encroachment with associated ground water table rise.This can cause reactivation of old sl ides (p.6-3,para.5). 3.)Concerns related to thawing permafrost. Unconsolidated deposits under a permafrost regime have a passive rigidity which is •abruptly diminished when thawed.Often this results in slow solifluction-like flows which may prove more of a nuisance than a hazard to facilities.However, the identification of permafrost in unconsolidated sediments an moderate to steep slopes prompt s: 3.A)The rapid flowage of supersaturated,thawed debris,often over still-frozen sediments in the subsurface (p.6-3,para.2;p.6-5,para.4). 3.B)Both surface infiltration and groundwater flow regimes will be enhanced by the thawing process,transmitting larger volumes of water to potential slide interfaces. 4.)Changes in groundwater regime. In addition to the groundwater affects mentioned above,the rise of water level in the reservoir filling process,and fluctuations qf that level,will significantly change the hydraulic gradient of groundwater in sediments and bedrock upslope from the water line.This causes both failure plane lubrication and hydraulic unloading ~f shear-resisting stresses on discontinuities. Susitna Hydro Feasibility Study Review Randall Updike Page 4 5.)Stress-state concerns. As far as I can discern the stability of the slopes within the reservoir basins is assumed to be a steady-state Syst~l.Two variable stress conditions come to mind. 5.A)The oversteepened valley walls are presently in disequilibrium with respect to previous rapid glacial unloading.This will occassionally be manifested by rock failure along steep,bedrock,glaciated surfaces (p.6-1, para.5-6). 5.B)Seismic accelerations which may not be'of concern to dam design,may be very significant in'slope stabil ity.I saw no mention of this. 6.)Rapid slides into reservinirs. It seems that one must be predisposed to consider that design-life big slides will occur into the reservoir.With this in mind I am concerned about: 6.A)The affect of sl ides along the margins of the reservoir which may over-run operational of recreational facilities (e.g.,roads,campgrounds). 6.B)Where slab failures are potentially to occur on steep slopes,the mass may be airborne and enter the lake along a ballistic path.This can generate cWavecsseveral tens of feet high which,in turn,affect: 6.B.1)Boats on the reservoirs 6.B.2)Facilities along the shore (across the lake,downstream and/or upstream) 6.B.J)Where the reservoir follows bends in the valley causing an enhanced additive affect off of these curves,resulting in progressively bigger waves at unpredicted locations downstream. 6.B.4)The dam itself,if the slide is near the dam,due to surging of water away from (drawdown),against,and over the dam,resulting in stresses exceeding dam design 1 imits Susitna Hydro Feasibil ity Study Review Randall Updike Page 5 6.C)Landsl ides may occur in part or ",holly below water-level in the reservoir which may not generate surface waves but could displace very large volumes of water resulting in surge or drawdown at the dam. Based upon the foregoing conmentary I feel that a strong plea must be made to examine the locations,types,magnitude,and potential frequency of reservoir-basin landslides.The soils and bedrock at the two sites suppor.t the feasibility of the project.However,slope studies,wave modeling,and possibly stabil i zat ion measures should be an integral part of the design and construct ion. Please reel free to contact me at 688-3555. RU!jlw Enclosures cc:Ross G.Schaff Bill Barnwell Di ck Reger S),usitna Hyct,ro Feasfbll ity Study RevJew'Randall Updi ke Page 6 ATTACHMENTS TO UPDIKE MEMORANDUM RE:Susitna Hy.dro Feasibility Study """'"I Figure 8 from Patton and Hendron (1974)on the following page shows some of the stress release phenomena that might be expected in the Susitna Project where steep glacial terrain is encountered. -~--::::::::::----~-~~~- -..::::-----------==---rtfr'--~~.- /1 /-.----t -' ~,/" V of::/;_•-d vh . ~I~POSSIBLE FAULTING ~I lOR.MXL9NITIC SEAMS ,~--.~-.r.::::-:'l"-,\~\'~"/J /I _I \,,,.=...."1 1..~--?>Z--ZONE OF STRESS CONCENTRATION tvv A)DEEP NARROW CANYONS TOPPLING AND OVERTURNING OF jlCE OR ROCK REMOVE__D STEEPLY DI PP I NG BEDS DUE TO 1----- RELEASE OF HORIZONTAL STRESSES -----\".~. /LINEAR T.Ro'UGHS \'\ \ \ ' \'\\,I I ~'.,.°./'"\\\,\ \ \\\~£ii,-,./\\\",'\ \ . \\,0\\ \ 'I f(\ \ \ \ . \ \ .\~\\'\.J ~,\'.~\\~\\ \.", \ \~\\~\\ \\\\~\\\~~~~\',<vh \ \\\ \\.\ \\'.\\'\ \ \q'\ , \\\'\'.\\\;,'"\,\\\\\\\\ t FAULTS DUE TO UNLOADING OF V v VALLEY BY EROS I ON OR .DEGLACIATION B)COMPLEX LARGE-SCALE MOUNTAIN STRUCTURES FIG.8 GEOLOGIC STRUCTURES RELATEDffO STRESS RELEASE IN MOUNTAIN VALLEYS Figure 9 from Patton and Hendron (1974)shows the potential for failure along the interface between unconsolidated surficial deposits (referred to as 'residual soil')and bedrock. Note the authors'emphasis on water conditions,which is also important at Susitna. A)POSITION OF SLOPE IN REGIONAL FLOW SYSTEM PIEZOMETRIC LEVEL IN B)DETAILED FLOW AND PORE-PRESSURE CONDITIONS FIG.9 POTENTIAL SLIDE IN RESIDUAL SOIL~TYPICAL ENVIRONMENT -i ""'" Figure 4 from Patton and Hendron (1974)showing the change in Piezometric levels as a result of the reservoir influence on aquifers.Figure 17 (following page)further shows how this piezometric change can influence a potential slide plane. FIG.4 CROSS SECTIONI SOUTH SASKATCHEWAN RIVER VALLEY 1 RIVERHURST 2000 -NORTHWEST SOUTHEAS II..P •.. ..'_.It ,........ ...··l:~·l .,· ..•......i,•III....-..._..,.:'• •n'::.•~.,, :' 1 ~,. J' .."'".... ,4 .~::::;:::::::::;::::;:::~:::;:;:1~:::::;:;:~::::::::::::;::::::;:::::::';::;:I:::t~S5!::::::l:1:::·:"::;:~·::::·~·l~·::::::,:;::·;::;·:..;·j~~1 "..-,,,~.,,-",,.,.••'".,'..,...:.It-.." •'..'......•'.•..r400 ..'..,:...~.',:...'.....I • '•••-.•I t ........,'.'.z.:".-.,...,"'...'...",'t l2 00 t ..·."'. . ..... .'.-....'........,..''....".'.. ...'...~'"-'..'....I'..,,'...........II·... .... ....... GLAC IAL DRI FT :~' • "......,1,~.,~. 4,"I~""• 1800 --· . ·B~~OCK s!i&AcE :~>'... ;Ji(\\~I ....,"""--=-•'~'::-1• •.......It...........__ ~oo -.. ......_.:.,............1 .•......'"....•._ '..'"'...~...~'. ETERS 0 1000 2000III1II FEET 0 2000 4000 6000 HORIZONTAL SCALE PIEZOMETRIC LEVELS AFTER RESERVOIR ,-"PI EZOMETR IC LEVELS BEFORE RESERVO IR I~~;l SAND AND GRAVEL 1-:·".1 SANDSTONEoSHALE 1 I -1 )-f J ]1 1 -1 1 J j 1 D Piezometric surface on plane abc after reservoir fills Piezometric surface on plane abc before reservoir fills -..-SURFACE OF SL I DING FIG.17 ILLUSTRATION OF THE SIMPLIFIED METHOD OF ANALYSIS I have included the following table which shows the measured wave heights associated with landslides entering large bodies of water. j ]I )1 ]]1 J 1 J j 1 !!"1"_!to~ J~~t.~1Y 7"J'"'/';1 (:t14 I~~h) At..ll.lJ'!l<'!'fl. 3':~.~~2L.r,·'.f/r.('70 ~!!!L- z..l~lJJ"'.I n.,y.A~e.P.:JI.Al q July J:.I'5~ l~') J.;)~'} :~~1lt :~1J3 ()r S4 r..--.kll!Kfona.J.,Allll.l!l.}(a? ;_'(~~p!~.!'~'" II'!;~~+j f,!,.AlA";':") ~7 !J4r":h 1 ,r.~. VaiQ"lt P.'!!"~"'It)~r,It.alY~ 'J l,):tctr:r :rt:~ JaM.,.."r.·"l£~IU !!!.l ;1 !lh>27'"1? 1;"""'/I.o.n;>:f~Orrll ~'~h;Ja.r~'~1~,6 !lnrVJLl 1..aJ-:e t"')\"ll '~J~~):",r/J '~0"j ]!~.~i'f.'''~l •r :1 ,)-, 21 ~f'j"""'""'t;~J"~)~(, 1::'n···.·~.ll'!'r l!~/l ll .....'W'rli '1'nf,:',J"d 1 I A;:>ri J 1 ')Jl "'I-:,.tteh~t 1'I,""'nt "-Y'.Ala.klll1 b ;"'I]Y J'I15 'n.n)o!;n D.hlJ(:~~'J"'lt !..a:ke.1 "11:,;h~I'li:·_,.n !l,....-I Ter~e Apr!~1 ~.!..;I ~Au.1...rt 19~J H,,~Cr"-k :-,.h.]/\1"':1 l'<;ll.,fi'J7"l- 2 ~ull"'k (I'./.) 1 TAck""""rl""\1'>';5) 4 ICJ ""clJ (l,,.,h Toble 2 Kht"rle Bll~.a ........ted IIaV1l! Wave Ma.x 8Ude GHd.8Ud.8114.V.tar ".nt HtI!19,t.t ~lJIUP ~'JI'!~Vol OUde Velocity Thiekn...Width Depth B114.VelocI t.y Wo.ot __ft_,_-LL '1'.111\',"eyl 810""-.ill-__l"t__-!L rt lpes,sravttx ~Vaft. 2 .2~(""",)30'115-}(,5 170 300 ]59 (--) 4.15 (lMX)21.1'115-185__321:'-~100 _359'....1 lJo 1j.10 ~~,40.0 40'93 2]00 400·100 2.1 91-]]0 1 100-250 hrXj Submarine 400-700 21!3 200 1joQ-7OQ 80 IIDck 40'400-700 3)5 400-700 30 12 Sedt-.nt Del t.1!lo ~110u,gh 0,2 2~104 ~'ne "".olMAtod 1S'3 (1 al"'~II lAni!elid.Breoltll1l!l 230 DIs 005 Rock...4,'to 116.5'50-100 6000 775 (.-)2.1 310 Total l~O In vlLt.er 33 Roek •9011 700 10'16,000 210 (-..)3 13 0 Rock'noll 15,1 25'1100 (-..)3 1~111 Ik",.0.45 6,'4]6 (_x) ]-6 230 Rook 1.3 11I65"1300 4]6 (...) 4~Rock 06,' 230 Sook 1.3 06,'436 (....) 104 Rock e.o 4~·700 (-..)13.4-26.8 15-1?O J1,(I]aelor 811de 16']500 9112 (...)1.0 65 ltoeoft""lldated 2]'160 (-..)45 SU4.. "5 lhtct11floUdft.ted )1'~O (MIl)3J ~tl":."" From:Banks,1972,Libby Dam Study April 16,1982 DEPAR~lENT OF ~J._T1.:R.AL RESOLJRCES'S TESTH-10:iY TO THE ALASKA POWER AUTHORITY BOARD OF DIRECTORS I appreciate the opportunity to provide comments to the Power Authority Board of Directors on the Susitna Hydroelectric proje~t.1 regret that, because of other commitments in Juneau,I am unable to personally deliver these comments. At the invitation of the Alaska Power Authority,the Department of Natural Resources has been working informally 'with the Authority over the last two years to help formulate and carry out studies designed to ans~er the questions which ultimately will determine whether the Susitna Darn proposals are feasible.The purpose of this testimony today is twofold:First,to identify Susitna Hydroelectric issues that are .~ithin·llt.e__sp..l:l~~.~.:.:.£f.~~R!.....s·:.~uthor:g:Y.j-·ap.d-.~~condrt0-!D~~C::O.£lP.l.~r!.q~.:::. tions to the Board of Directors on the continuation_of project develop- ment,as reques~ed in the January 26 letter from Mr.Conway. SUSITNA HYDROELECTRIC RELATED ISSUES WITHIN THE PURVIEW OF THE DEPARTMENT OF NATURAL RESOURCES Tne Departillent of Natural Resources will be required to make decisions on two major facets of the Susitna Hydroelectric Project.These are: 1.DNR responsibilities for water appropriation (and possibly instream flow reservations)'fron:the Susitna River. 2.Rights-of-~ay permits for access into the dam-sites and transmission line routes.Other land use permits for access to construction sites, gravel for construction,and other land use related needs as they occur on state o~~ed lands. The role of the Department of Natural Resources in water rights appro- priation will be an adjudicatory one.According to Alaska Statute 46.15.030 (b),the impacts of water appropriation on the public interest shall be considered during adjudication.Areas of public interest are defined in the Statute as follows: 1.The benefit to the applicant resulting from the proposed appropriation. 2.The effect of the economic activity resulting from the proposed appropriatior:. 3.The effect on fish and game resources and on public recreational opportunities. 4.The effect on public health. 1--'--·-- .- - 5.The effect of loss of alternate uses of ....ater that might be made W'i:hin reasonable time if not precluded or hindered by the proposec appropriation. 6.'Harm to other persons resulting from the proposed appropriation. 7.The intent and ability of the applicant to complete the appro- priation . 8.The effect upon access to navigable waters. The DNR will be looking to the Feasibility Study data and information to describe the relationship between various streamflow levels and how they will impact fisheries.and aquatic habitat downstream.Thus,from this Department·sperspective,instream flow studies and the relationship of various floW'levels to aquatic habitats and fisheries resources are vital.The studies administered by the APA will be the fundamental sO.Y.rc:£....2.f dat?_an~,,,":i;.n.t~aE"i.-9£_~~ed 1?,Y.J>~..R~~k$.~J1e.public int~rest fi-nd i1rg'S""'"d eSl:T±b-ed"c:rl1o ve.We"a 1 1::ea"g"et"""'t'o d'r e~:tl!W'-and--c ormnenr upoIcth e- present and future plans for instream flow sflidie-s.To date,we have not been provided an opportunity to review or comment upon the instream flow study approach. The access to the dam sites and the policy surrounding the extent of access after construction ~~ll lead to one of the most significant impacts of the project.The Power Authority has stated that the permit for use of a "pioneer road"is needed in 1982 (before a F.E.R.C.permit is issued)if the power is to be on line eleven years later.One signifi- cant issue is the possibility of the construction of a road to the proposed dam sites and a subsequent decision by the state not to construct the da~s.It would appear to be in the best interest of the Power Au tilOri ty,the land managinl;agencies,and the public to identify other alternatives which will a1lm.·the necessary access to the proposed dam sites in a manner which prevents irreversible impacts.In order to prevent this issue from bein£a potential delay in progress,we recommend that the APA take the lead in convening a multi-agency,multi-disciplinary effort to accomplish the goal stated above. The second issue is the long term land use implications of access to the proposed dare sites.The provision of access to the dam sites should not unwittingly determine the types and extent of land use impact on the surrounding lands in the upper Susitna Valley.Carefully determined access route decisions could result in a multiple purpose route which could facilitate and enhance other uses of the surrounding lands.In order LO accomplish this,tn~dam access route decision should be made in conjunction W'ith surrounding land owners,land managers,and the general public.As on the other-issue above,the DNR is willing to participate cooperatively with the Alaska Power Authority,other agencies, and the public to resolve this matter so thac it does not:become a potential delaying factor for the proposed project or a future manage- ment problem for land Olo.'llers and managers. Sill-l}l.ARY AND RECm-fr1ENDATIONS In sua~ary,cne Department of ~atural Resources has three reco~enda­ t ions: 1.The Department supporcs continued studies in the socio-economic, technical,and environmental areas.The preliminary work accomplished so far indicates that the project is technically feasible."Further work is needed to establish the information and data for water appropriation and fishery mitigation.Additionally,we recommend further work on the timing,route and conditions of access to the proposed dam sites. 2.With respect to the question of"whether it is desirable to submit an application to the F.E.R.C.on September 30,1982,we F offer the following comments.The APA Board of Directors and the staff should carefully weigh the advantages and disadvantages of jmbmitting "the-formal apP"licatyicn·an~S~ptember--30i""-1982.If that course of action would result in the iU'A acqu.~.l.~u!!>a r.r...R.C. permit to construct in the most timely and economical way.the~ that course of action makes sense.However,if on the other hand, a formal application would result in delays,increased potentials for litigation,and a hardening of adversarial roles between the APA,other agencies,and other interested parties,then the possibility of these delays should be considered.We believe that the APA Board and the Staff are in the best position to evaluate pros and cons and to determine whether a F.E.R.C.application on September 30,1982,is desirable or not.From our more narrow agency standpoint,DNR is not opposed to a F .E.R.C.application so long as our agency concerns and responsibilities can be fully and openly determined through the traditional intervenor process. 3.We compliment the APA Board of Directors and staff for encour- aging inter-agency interdisciplinary approach to identify ways to improve the coordination and ultimately the results of the feasibility studies.We believe that strengtneriirig this approach will facilitate" a more cooperative and constructive role for those agencies which have responsibilities that require them to take action on the Susitna Hydroelectric Project.Specifically,we recommend strength- ening and enhancing the role of a group similar to the Susitna Hydroelectric Steering Committee which has been providing informal agency comments to the APA on this project for the last two years. - September 2.1982 Ms.Lei!McAnerney.COIIIBissioner Department of CoaDun1ty and Regional Affairs Pouch B Juneau,Aliska 99811 Dear CoIIrlss1oner MeAnemey:Sus1tna Hydroelectric Project During the second quarter of this year.the Alaska Power Authority circulated the draft Feasibility Report on the Susttn.Hydroelectric Projectancl nwnerous supporting documents to State,Federal and local agencies with interest in the project.fb1s circulation included virtually all of the data and analysis done to that date during the study.Currently.efforts are proceeding towards cOllPleUng the first phase of planning efforts and submitting a license application to the Feden,l Energy Regulatory CORIiss1on in the first quarter of 1983. " During the remaining t1_before fl1ing,the Susttna study tea.. will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project tAq)acts.·Th1s effort will include requesting another review of the project's Environmental Report, which is the draft of the FERC license application Exhibit E.by your agency.We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC.there will be another opportunity to comment on the application,including Exhibit E. At this time we would appreciate any input into the continued plan development you could provide.In particular.we request your guidance with regard to project impacts and tbe mtt1gation opportunities your agency would recOllllend.These cOIIIIents w11l be helpful both in identi- fying and addressing the IIOst important areas of concern in tl'te next draft Exhibit E and in docu.ent1ng agency comments and recommendations before FERC.In order to address these cou-nts fn the draft,it would be mst helpful to have them by the first of OCtober. As you know.the planning process is dynamic.Current efforts are focused on project access,trans.fssion corridors and project operation alternatives.Although this information has not yet been distributed for comment,it will be included in the Exhibit E draft. September-:Zt 19~ CoaIDissioner McAnerney . Page 2 we welcome your comment on all areas of the project,but,in accordance with Section 4.41 of the fERCregulat1ons.we are part1cular~ ly interested in your comments with regard to archeological and historical,and socioeconomic issues.In these areas,we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your continued support and participation in the development of the Susitna project license application is greatly appreciated. Very trUly yours, SIGNED Eric P.Yould Executive Director EPY:mb cc:Mr.J.Hayden Mr.Lawrence H.Kimball,Jr. DEPT.OF COBBUNITY A REGIONAL AFFAJRS October 4,1982 Mr.fric P.Yould Executive Director Alaska Power Authority 334 W.5th Avenue Anchorage.AK 99501 Dear Mr.Yould: 225 CORDO VA,BUILDING B ANCHORAGE,ALASKA 99501 OCT 121982 ALASKA POV1ER AUTHORITY .... Your letter of September 2.1982 requested this Department's guidance regarding potential impacts of the Susitna Hydroelectric Project and mitigation measures that might be appropriate.Regarding potential project impacts.we would refer you to our letter of May 28.1982 which expressed our concerns relative to impacts.The issues raised and points made in that letter remain valid. In terms of mitigation measures.it would be more productive to offer detailed suggestions once the draft Feasibility Report is revised to incorporate comments of reviewers and then circulated for review. We would at this time encourage continued close coordination with the Matanuska-Susitna Borough.Cook Inlet Region.Inc.and appropriate State and federal agencies during revision of project reports and preparation of FERC application materials. Si ncere ly. Lu.foM.~ Lee McAnerney ~ Commissioner - cc:Lawrence H.Kimball.Jr .•Director Division of Community Planning Al Carson.Chairman Susitna Hydroelectric Steering Committee Gary Thurlow.Manager Matanuska-Susitna Borough Claudio Arenas.Planning Director Matunuska-Susitna Borough September Z,1982 Hr.Keith Schreiner Regional Director,Region 7u.s.Fish and Wildlife service 1011 E.Tudor Road Anchorage.Alaska 99503 Dear Mr.Schreiner:Sus1tna Hydroelectric Proj~ During the second quarter of'this year,the Alaska Power Authorit)"c c1reulated the draft Feasibility Report on the Sus1tna Hydroelectric Project and numerous supporting documents to State.Federal and local agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study.Currently,.efforts are proceeding towards completing the first phase of planning efforts and 5ublntt1ng a license application to the Federal Energy Regulatory COIIIIhsion in the fint quarter of 1983. During the reIIIl1ning time before filing,.the SUs1tna study tea. will be refining the plans presented earlier this year and continuing to evolve-proposed ..itigat1cm plans for project impacts.This effort will include requesting another rev1ew of the project's Environmental Report. which is the draft of the FERC license application Exhibit E,by your agency.We will be circulating the draft 1n mid-November of this yearQ AFter filing with and acceptance of the application by FERe.there will be another opportunity to cORIEnt on the application,including Exhibit E. At this time we would appreciate any input into the continued plan development you could provide.In particular,we request your guidance with regand to project impacts and the mitigation opportunities your agency would recOlllDef\d...These coaments will be helpful both in identi- fying and addressing the most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERe.In order to address these COllllletlU in the draft.it would be.IIIOst helpful to ha.ve them by the first of October .. As,you know,the planning process is dynamic.Current efforts an focused on project access,transmission corridors and project operation alternatives.Although this information has not yet been distributed for comaent,it will be included in the Exhibit E draft. ...... - ..- - - / 5eptellber 2.191.. -Mr.Keitb Schreiner Page 2 We we1cOBIe your conmenton 811 areas of the project.but,in· accordance with Section 4.41 of the FERC regulations,we are particular- ly interested in your cOIIIIIents with regard to fish,wildlife and habitat.In these areas,we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your continued support and part1c1pat1oninthe develop;entof tbe Susiba project license application 1sgreaUy appreciated., Very truly yours. SIGNED Eric P.Yould Executive Director EPY:mb cc:Mr.J.Hayden Mr.Robert Bowker Mr.Gary Stackhouse IN REPLY f~EFEI1 TO lJi\ES United States Departlnen(of the Interior FISII ANI)\\'1 LUl.l I'!.-,St-,/{v IC£ lOll E,TUDOI{I{l), !\NC!lOI{:\(;E,AL/\SK!\9450J ('J07):!76-JHOO 05 OCT 1982 Eric Yould,Executive Director Alaska Power Authority 334 l~est S!!!.Avenue Anchorage,Alaska 99501 Dear Hr.Yould: This responds to your letter dated 2 Septe~ber 1982 requesting Fish and Wildlife Service (FWS)input on Susitna Hydroelectric project impacts and potential mitigation pertaining to fish and wildlife resources.We have previously provided as input to the Alaska Power Authority (APA)and its consultants some of our concerns.Please reference the testi~ony presented to the APA Board by Deputy Regional Director LeRoy Sowl,~/S,on 16 April 1982, our letters dated 15 November 1979,23 June 1980,30 December 1980,5 January 1982,and 17 August 1982,and the Susitna Hydro Steering Committee (SHSC) letter dated 5 March 1982.We expect that the issues raised in these letters fnd testimony would be addressed in the license application.We anticipate ~aking additional comments after our review of tile 1982 field data and analysis and during our forma 1 consu1tation review of the draft Federa1 Energy Regu1atory Commission (FERC)license application Exhibit E. Presently,the FWS is interna11y reviewing a draft document prepared under the auspices of the FWS Hitigation Policy (F.R.Vo1.46,140.15,23 January 1981).The purpose of this document is to establish for this agency project area Resource Categories and the corresponding mitigation goals.Following completion of our internal review,the draft document will ~e provided to the Alaska Department of Fish and Game (ADF&G),the Environmental Protection Agency,and the National Marine Fisheries Service for a 30-day review period. Following incorporation of comments from these agencies the document will be released to the APA and the FERC.We expect to issue the document around 15 December 1982.By providing this ana1ysis we intend to:(1)allow the APA and FERC to anticipate FWS recommendations and p1an for mitigation needs;and (2)reduce potential conf1icts and project de1ays.It is the intention of the FWS to protect and conserve the most important and va1uab1e fish and wild1ife resources while facilitating balanced deyelopment of the nation's natural resources.Copies of our Mitigation Policy have been previously provided to you.If you need additional copies p1ease do not hesitate to contact the Field Supervisor,U.S.Fish and Wi1dlife Service,605 W.4!!!.Avenue,Room G-81,Anchorage,Alaska 99501-(907-271-4575). The f0110wing comments shou1d not be considered as superseding comments previous1y provided or foreclosing future opportunities to provide input on fish and wildlife resouce impacts and mitigation options,prior to,and during the FERC licensing process. I I..II t.'j II J '_t-,;J; ,dl:JPO S i ~i I)ii, flu'...'if:~[__'our,',~-d ~.ur·_J r0~;lj;lL ~~ur~)i·j i ~~-.I,tJt~:1 ~il(J'~,ChQJ.i 1C ...1; ,1:1,.1 Ii U L r 'I c :I ~i '.c'v~1::,;:0 rolili 11 Li i 11 lll.:'::xi::;till ~I ~i ;;i I e r ~'511 J U I (! -- I 't 'f u)).:,'(~v'"I U<1 t e J ..Tr.L,\..'J 1I )d Pr oj v i tk t h ~b<1 S '':)inC'lJ:::\I h i;:h ~1l"G j ec t 1i::i)dCt::;cau),J lJC ev::ludU..:";.[7ur instJllCe,,10\-:and to ~..hat ext~nc t!l12 :l1'ujecL ~'Quld nocifj':ll"t::seri:'CJllditiollS,hal!t.1<25C clian(jes ~iould ir,l;>act i ;,0:;i t i vel y 01-11 e:j a i.i v::1:,<t n '2 !J i 0 'c Ll,\.:h <1 to pro j ec t mo d i f i cat ion S co u 1<.1 be lIrdel~~aken to i;linii;:i:e,(n-(-?7ii.iillat~adverse impacts,and ir.lpa::ts of Il1cremental changes in thes,::parameters should be fully assessed. :';itigation options J:lust Lle examined on the basis of a defensible, ,jllil.ntified ili1pact analysis. flan:.of thest!concerns ,,,ere rti ised previously.I·Je refer yOLi to SutltG'.sk 7.10 ;:"i:;1;Lcology:A Sur'le/of Questioll:;anG Concerns Pertaining to Instrear.l Flo\-J ASpt'"ts of the Pruposed Sus i tnu Hydroe lectric Project (r:ay 1981)ane Su~task 7.1,';;ish Ecology:Instrear:J F'lOH Assessment for the Proposed Susitna H~··,::·,',.~12ctric PrJject Issui::Je:;:ifica:ion and Baseline Data Analysis 1981 SUI1l11,Il'y Report (?lal~::~;19S2).lie exp-:ct tilat ti1~iS5ues identified in these rep,·!·~s IJill be reeva bated in 1 ight of the 1332 fi€ld season. To .h1lieve the afor~l;]en:ioneC:goals,the a;'lalysis raust provide the fol1O\·;ing: a ...:ilc1ntify the relationshiu ~et\Jeer,r:1ain:itream disc~;arge and the .tV",iTa:;l'ity of fis..'".rtc1:,jj;:a~uy 7ife stage (DasSa,je,nil1ing,spa\·mir.~, I'~arin~),in t\:'slougri5,side ::nanne1s,and lilain::;treaiol. b.I:,sess the inter!"'e1cJ.tlo:Js!,i;.;of the Susitna Rive:t:;it::;tritJutaries in l';.·gar-j tCi fishery ha.~ii:a~r:quirements '{S.11ft::stage. c.!;lJntif}tilt;relc.ti'Jns~i~;~je:ije€r,ar:arra;'of 7101;re;;ime=.and fish 'l.l:'~itaI'c.::nms:rear.l ~lr -:-etl,:e·:?-;;nc:tt;rou'J~lOU~the yeal~. d.~dentify the source,flo,;..,cner.:ical and ter,1perature characteristics of \,pl-Jelling ~-Iater 'in ::ne :ilougi1~an:.J~heir relationship to r:Jainstreai:1 ;onditions throughout the year.This should include an evaluation of the :'1fluence of ice cover or;til02 rela.:ionsbip betrieen the mainstrean anc the :-loughs. e.;:J,seI ine surface and int('~gravel temperature data sufficient to describe :.ne annua 1 therma 1 rE:'ililes ai th,~rna in5trear.t river t side channe 1s,and :-:lough;;above Til 1keetna.The relationship of these three river COfiliJOnents 17Jst be establisilec to~i1o\l a realistic assessment of potential project ::;lpacts. f.:ile relationship lJet\-Ieen a~bient and potential project-caused temperature ,;ollditions and salr.ioll er.ibryo survival and rate of development. 9.:-ne viability of slough I:lodifications to increase fishery habitat needs to "'-=der:Jorlstrated. T:ll 10110 I"",~II'JL ir:;plfco.;:;Oil:"~i P~';)iJu,(:,-,i)!'.),~":.I IU,;~v:;.Id~i1r'd: flo\Js Jill.!putelltiel1 liu~iL.l~IIIJi!:~cllJIIC'~fj~J',,:1:L'nL :;;,)J~~iuJr_' :;I 0\/i J S S 0 'Ie .,;I (J u g:,S,<111 ::1J S~1.1::L,s';j »:;,j ..'~•i I I"_',J Ll I;:~',L;'_' in~(j cOI,::iderJtiCJr:lUll';)cc'n;1 OII(lJ.;,1 c,llu ~'kJM,j cUII;i'JLlI·Jtil)li~. Silln!J11 ejlilunCei;T(?rJ:'ootc!il i.;J i.il.hJV'.U<.:V i ~',.:li:~'J:;:j LII\)Ui:.cilCe ~u:..i [;1.- proj£;!ct,\:itil tile S~;;itllci pt-oject ilwl ~i1t::linJ<lC:";uf Jllj'iJrO:.Jr"ill,1 t:: ~5tabiish ~all::ol1 ill t;,e uppc:'j-iVC1'ai,..;;.;i:;·~L1,;Fisijl2l"i~.:;, particularly grayling.Considel-ation snoul.:r I)....~ivel1 to potential conflicts bet~,eell mitigation options to offset pl-oject-caused losse~ to grayling vs.salmon. j. I,". , I • The potent i ..I to esta:.J 1i sll/expantl tile sa lliiOll fi :;hel-y lJetueell t:le Devi 1 Canyon and Watana dalil sites ii.tile absence of u.Devil Canyon de ve 10 pt:len t. ~Jit:,in and ot:t-of-uasiil oppor~unities tu offset lOSSeS to fisile\~ies SUCll as streal;t stocking,1a:~e fertilization,<:xtension of existin] fis;,eries,and lilcreasin:j puj1ic fisil1ii9 ac:~ss d"d oppurtuni:ies. Extent 'of de~',aterin9 uetiYeel1 the Devi 1 Ca,lYo;:dar:;ana its pO\Jerhouse aile c;.~sociated fisi1~r~'ii:lpacts,an";Illiti;Ja:iol:ojJtions. 1:1.Pre-and post-project nitrogen levels ill Devil ~anyon and impacts. n.Je:,u t{i 0 riA 1 lii)pacts r",~~c:t2d to c;.ail ces i i~~1;;.4':"')'~ei;lDel~a tut~)a d~ cilefilica 1 composition of tiH:Sus ima ;·~ive!"(;~E -::C :Ile proposed proj:=:'':. ~.T;,~ir.:pa::of :h.:l:1g2~1:·,~:1;-;::er 710'.•'$,~~i:;~~~t....,c~1er.;~c~1 composition,salinity levels,and ti~ins an:exten:of ice formation •~n.-""r"'a;'up .....r "'l"~'""'-t.'"at-"Co I.""u \;;I".-.V I L....\..iC..I w..i. p.Tile vic..l.Jility of a n~seno;r fis;'I:;r}nc:~':i.;:;.,•.<:evaI\Ji:T.e;:';tnlqous.,all assessment of:predicteG res:rvoi,telilperc:.:ures,turbidity.cller,iica 1 composition ana ailticiputeG Drif;lat·~,prodiJc'.:ivi;:j.',av"i1able ~pa.min~ habitat.potential for estab1isning spalmin:naoitat.and the 1~:::1a t i onsh i p of a reserve i r f i snery to {,;5~il"":i S;H:J tri uutar<./ fisheries. q.rne timing,extent,and :;-=a.sonal variaLi1it~'0,'Jaiiy peal~in;:i l'lllic!: ~'lOu 1d occur vii th either a one or t~o daf,i :;y:;;:eioi and tne.:assoc i a tee; aquatic ir.ipacts. r.Hydraulic turbine configuration.:>i/ith Joti.a 011':all(j tilO dahl configUl~ation related to maxir.l;Z;l1g fioll l-eiease options VS.more flexible turbine system alternatives. s.The impacts of anticipated operation flO\'I releas~~chedules 011 tilE aquatic system during a critical 10\1 \later period. - - ...... T~IL'()11'Juill~.i \;ilL11ifl.'~;tudic'~Jre iH"UVldill~t!lC ~JJ:;i::;Updl:',;!;iC:i ii,ipJC as:;essr,lcn"und l,iiti~rHiJII ;JIJl1nins t;l!~'':~)lJcc.lie iJf~liC!vc l~hc present ::;tu'ji~s rlt:i::d ~CJ be rc:liltt:!rj to habiti1~vdlu~.f-'opulation ~stil.l"lt;:;,~y thel;::;elv'25,-1re often l;nreJiclGI.:inJiCJtors for ~:valuiltin~project ir;l\JdCt::,Ull fisti J.fhi lJiI ..:lifc n:sourccs.Saf:i~'Jin'J Cl~rOr$,cyclic fluctuatiol1s ~f populations,anu tlle IJc~::If thes series dat<l al1 contribute to this unreJiJ::>ility_The Fl..J$ lJf!I i eve s thil t nabi ta t va 1ue Uel s~d upon predi c ted carr-y i I1J C apuc i tj and IIUlilan use data is a much better basis for determining mitigation requirements. liO\'1ever,consideration of impacts of a project directly to fish and \·lilJlife populations should not be foreclosed.Population information can be an important supplement in fish and \-:ildlife r.1itigation planning. He support the species specific ~itigation planning based upon the National Enviro~cntal Policy Act guidelines (i.e.,to first try :0 avoid any adverse ili1pact.s,then if that is not pos~ible,to r.linir.lize,etc.).naxir.lum efforts should be put forth to avoid adverse ililflacts to r.loos~,:ariiJolJ,urmll1 beal", Dlac~bear,gray ~olf,Dall sheep,baaver,~ine ~ar:en,bald eagle,golden el1']le,and trumpetel"s~:an.\It!con5ider trlEse ',lildlife species as ~,avinCj high pu~lic intere5t,economic value,and ecologic&l significance in terms of trac~i~~project-related i~pact~to ha~itat values. Additiona7 terrestrial icpact~and ~iti;ation inv~stigations shoulj examine: 1.disposal of I:iate"r;al c·.:avat2d at the Devil Can:/on saddlac.larli. ;:.Procedures anG evaluation 07 the pot:ential and fJr-z.c~i::~lit~·of dis'Cul"t)e·1 area rehabilitation. 3.Viability of presc~fbed ~ur~ing in the u~per Su~itna ~asi~to cocpensate for l'loose habitat lcz:;ss evaluated through an exar.;inat iOil of 3\.ireali of Land f1anagemen:bur:.s,historic burns,and enclosure studies.Poten:::ial areas of 1m!habitat value tinier:could be enhanced through bur:1ing should be identified.flrE:a.5 of interest should include sites '"hich presently have 10\~or declining numbers of moose and good public access,and it can be established that ~abitat ~anipuTation,such a~prescribed burning, would increase habitat value. 4.Anticipated project-related changes to the ripal"ian vegetation fron Devil Canyon to Ta l:';eetna anddD\'Jnstr:ar.1 from 'Ta lkcetna shou 1d be eva 1uated 'iii th ccn:iideration being '~iven to the lJenefits or dl"il\:bac!~~of acceleratin J , decelerating,or Iilaintainin:;the existinl~conditions. 5.Telaporal use of the Jay Creek Dall sheep l!iineral lic!~Silould be documented.The chemica 1 co~pos ition of the rninera 1 1 ick I/OU ld need to he determinee and ident ica 1 art ifica lb locks set out exper imenta 11y if inundation of the mineral lic:!~~/ou7d be u[1avoidable at the time it is norma lly used • L't t"c(':U:J!lj~l·::;j,~t .~li d lol"'~fc ;~'-tJJ~CL ~~C~.Ll~':.n d •~U.li~~i .....;Y~~~"u~;~\ct)"ic iH·O.J~C~,::;:.uuy ':Ol;:;.i0rlcn t:;dr ...U::,U;j J 1)::Dr::;J,jr~;;jt.C:~l:",;;;::,>.....::'::-1 i:;i:;ethud,i,; :!)I.l~lc:,:priJ:;l~I.:~)~COI:le::;::la:Jil:;eu.:l1e.ijij.:,,;ver,'J:';~;Ji,U\:'-i::1C:Jtjli.:i!l'J,iJ larg~ iJl.lrti~l!i:.:;::Iace..i 01\cool·din:.ti:i~ll.T:i~p1eces OJ:'':.!,'::.::,j;::.:k i.lUSt.u€con~tdnt:y ::l(JII itOr2d to ilSSilrc th.it thej';;i I J Pi\:W:iNliCl-a:t!ll'~:l:~'Jf t!lc·~'"<h."'€-ss.He cH-e caiiccrneu thai:.the present S~'S::21~:'JT h,}vin~~<2:)ilrate subcontractors ~lriti;1j tiH::aquatic an~terrestrial conponcnts OT tile r-:T:licellse application Exnibit £:and the schedulin'}constraints placed I,lPOll these subcontractors will not al1O\!for a thorougr.analysis of the intelT-=lu.:iol1ship of the aquatic and terrestrial studies. ~dditional Jquatic and terrestrial i!i1pacts and nitijiJ:iol1 considerations should be examined. 1.~~lanIJes in the existin:;ice pattenls and reI i~bl~Dredi;:~ion::;of 'iJhat ti12se pa~erns-->iG;r1-d---he-ffith t!':e project oust be ;Jfo'.!ided to aiio~1 a full ~s~55l:ien-::of poten:ial ir::pacts tc the fis!~an":i;n::)if~resources.The fol1m:in~inforQatio~woul~ai~in an evaluatio~of project ice-related re~ervoir i~?acts. c..The tir.lin;of fontla~i;:m,e;;tci1::,th i;:;;~ne:::;,a~d t1r1~of brea:::up of reservoir ice.Th~~vault need :0 DC re!a:ed :0 potential wildlife )...t2servoir cj"'o5sin~~ite::s~c!;a.s 1IaL:5.nc.:l'"~~~~f:r-c:z:.r;cQua u.Tite car.1Dositior:ill1~,;my:;ica::j;Jrac:e"~:;:i::J-;ti,,:;reserv~ir shoreii~l~and ::ic1\ic.lm,m :ones afl~expe:;:atiJ::.::::;l'~C~~helvin:j. Tile f:J7Im':in;in'fol"!;Jatior.llOuld a.id in an cvaiua~;o:~']7 ;;rcjec:ice-related ir::iJc:r:,jOlJns:rr::a.froll ue"i ~Canyon: c.tn~~'.:ilTin9 of farnation,extent,thic::n·':::i5.a:1,j ~ilile of Jreakup of ice Y5.d range of water rel~ases and winter conditions.Evaluation a~tr.is inforr.1atioll should then be directec.:tOl/eJl'""-G:I:hat ..Iould be the i@pact on beaver,moose.salmon utilization of the mainstrea~, grayling and other resident fishery use of th2 nainstream,the extent a"~ir.1pact of iCE fag conditions on riparian vegetation. ~.Tile extent to ~,rl1ici;ice functians in cnann~l fon:1Ution and liIodification and predicted change:in this rJ7e. c.The pre-~rcject ir.1portance of ice as an inflU2nce in nabitat changes and anticipated post-project condition:. ~'--Irntlacts of the project on users of fish and liildlife resources,such as: a.commercial fishery use.; b.llig game and fishin'j pl'ofe~sional guides; c.subsistence use; d.trappers; ,; I. - - j.increased fi:;h <1lld \'lildlife user population iii the rJibelt. __.lh~inte;-rela:iol1~hip bet .....een poten:ial impacts to and r,l'iti;ation o~tiol1:; for sal~on and wildlife species dependent upon aquatic habitats,such as beaver,moose,sflOrebirds,dnd t11ack and brOlIn bears. 4.Adjustments to the Watana reservoir filTing schedule to mlnlrnlze impacts to fish and ~ildlife resources such as salmon,grayling.cari~ou~and 1I00se. -.quantification of aquatic ~nd terrestrial haLitatto be inundated dUE to the proposed dau h~ight and what an array of lower dam heights would mean in :eri:iS of lesseniil~ha:.Jitat losses. ~.:ia~l!litudEJ duration,~nd fr-equenc)of occurrence :>f da.il~'fluctl.!ations and :h2ir ir::pacts on fiii:and \:ildTife l'~sources ;dti',both a one and two dal;i syster.;. 7.Disposal of I,iateriai excavated frot;tailrace an(~pOlle,"t~nli21s,saddlcdai',; dn~Jenera)aa~cons:ruction and potentiJl uses. :..I~~act~of the construction vill30e,uer~anent village.and alternative: to the prop05edsy~~e~to ~ini~iz;ad~ersc fi:h a~d ~ildlife r?5QUrces. Tioin;restrictions to oinirnize adverse impacts duc to ac~ess road, tra~5!:1ission Tines.and aar.i construction. lu.The i~pacts due to construction and oaintenance of the transnission lines and acceS5 road need to bE fully evaluated.This should include a cOGplete fish anG ;tildlife iopact assessQent of borrow areas and access to thes~sites. 11.:lhi:1izir::J fish and \·tildlife iopact:through proper tir.lhG 0;,/oody r;1aterial rer:toval in tile iopoundoent areas.Consideration needs to be giv~n ~o acceptable ~ethods of dispo~al of this ~aterial. r:.liJl1~liny of hazardous materials t:J am;at the con~truction sites and safety precautions. Although \/e are fJrovidin':;J inforTolation which vlould facilitate-your project objective of ~uboitting a license application in February 1933,-\/E:continue to urge you to defer license suumittal at least until the 1982 field data can be fully evaluated.CO::lf,lunicattons between mi staff and those involved in ]Jtl1l!rill];!JrJ inJicJt<:tiliJt lie sllould ~.'\jJec;.tv UII,jet":.i~Jli,J !.IUCII l.IUI"l' tilorough l'j tile resour'ces of the Sus i tllil S t l/uy J.I"eJ iJ ftet'till:.~'l!ill". :~itiJ.l~iOII ~l<lllilitl.j s:lOul.l :.10 f(]l'::'il LJJSet;"i'ti<l ::ilL I.IU!"'.:CUl.ljJlc,>.: ;Jmlerstandillg of tile resourc~s JtlJ thl!re:'u 1t.lIlL '}SSCS~[:lellt vi tJ1"uject iupocts. ,.',..":\~L~v----~tV\D-~ ~1.tJ...I "~Reglona Dlrector cc:FlJS -ROES,IJAES Questin Edson(FERC Larry r-toulton/Uooduard-Clyde Robin Sener/LGL !/l1FS,EPA,:IPS.USGS,ADEC,.t\EIDC A1 Carsonl AOIIR ADF&G.Hi:lb Oiv.,S:.l Hydro St:.ldics .... The preceding letter was received;responses appear below. Aquatic Studies We believe that many of the questions raised in your letter have been addressed in the draft license application and the license review workshop. However~to reiterate somewhat~we recognize the need to develop a data base respective to the physio-chemical process of the Susitna River which~in turn,will allow us to predict the impact of the project. Realizing that factor by factor analyses is insufficient to predict project aquatic impacts~a model which incorporates the factors is being developed.The model is project specific and complex.Preliminary physical data for use in the model will be included in the February 15th FERC license application.The model~however~will not be available for use until June 1983,and we expect that useful analysis will begin to be available in the fall of 1983. With respect to the specific aquatic analytical goals mentioned in your letter,please refer to the following: "a •Quantify the relationship between maintream discharge and the availability of fish habitat by life stage (passage,milling~ spawning,rearing),in the sloughs~side channels,and mainstream.II Determination of fisheries habitat requirements,availability of said habitats,quantification,and incremental changes in habitat quantity re- sponsive to discharge will be accomplished in the basic steps.The first is development of relationships that describe habitat suitability in terms of physical parameters.This first step is underway,and we expect those re- lationships to be available by June 1983 in the ADF&G habitat analysis report.The second step will be to use the aquatic habitat model to pre- dict the changes in habitat availability with respect to various project operating scenarios. lib.Assess the interrelationship of the Susitna River to its tri- butaries in regard to fishery habitat requirements vs.life stage.II We recognize the significance of the mainstem Susitna River to provide for migration and rearing of tributary bound or spawned fish.Efforts are underway to further refine our understanding of mainstem utilization. "c.Quantify the relationshp between an array of flow regimes and fish habitat downstream of Talkeetna throughout the year.II We have not embarked ona program to estabJish the relationship of flow regimes and habitat availability below Talkeetna,although physical data has been collected below Talkeetna.Impact assessment has been con- ducted on an area priority basis.The highest priority areas are those within the ,impoundment zone.The second priority area is that between Devil Canyon and Talkeetna.The lowest priority area is that below Talkeetna.To date,investigations related to the area up river of Talkeetna have not in- dicated a need to rigorously assess aquatic impacts below Talkeetna.If~ however~it becomes apparent that impacts below Talkeetna may be significant, that area too will be rigorously investigated. "d.Identify the source,flow,chemical and temperature character- istics of upwelling water in the sloughs and their relationship to ma'i'nstream conditi ons throughout the year.Thi s shoul d incl ude an evaluation of the influence of ice cover on the relationship between the mainstream and the sloughs." The relationships between mainstream conditions and slough upwelling waters have always been recognized as being potentially significant.To define that relationship,ground water studies have been initiated in rep- resentative sloughs.Ground water observation wells indicate that the up- welling in the sloughs,which is necessary for -egg .incubation,is caused by ground water flow from the uplands and from the mainsteam Susitna.The higher permeability of the valley bottom sediments (sand-gravel-cobble- alluvium)compared with the till mantle and bedrock of the valley sides indicates that the mainstem Susitna River is the major source of ground water inflow in the sloughs.Preliminary estimates of the travel time of the ground water from the mainstem to the sloughs indicate a time on the order of about six months. We also recognize that ice cover on the mainstem will influence ground water hydraulics,for example,when there is an increased stage due to ice cover. In addition,ground water wells have been equipped with thermistor strings and piezometers to monitor temperature and pressure.The dissolved oxygen content of these ground waters is also periodically determined. "e.Baseline surface al')d intergravel temperature data sufficient to describe the annual thermal regimes of the maintream river,side channels,and sloughs above Talkeetna.The relationship of these three river components must be established to allow realistic assessment of potenti a1 proj ect impacts." Temperature data,especially as it relates to salmonid habitat,is being gathered.Surface and intergravel water temperatures will be monitored both instantaneously and continuously. "f.The relationship between ambient and potential project-caused temperature conditions and salmon embryo survival and rate of development." This relationship is currently being investigation by U.S.Fish and Wildlife Services at the Anchorage research facilities.Chum and sockeye salmon eggs from Susitna River slough are being incubated at four thermal regimes including one that mimics a representative slough.Development rates are followed,noted,and compared to the in situ development. "g.The viability of slough modifications to increase fishery habitat needs to be demonstrated." There are plans to conduct a slough modification demonstration project this year.This program will help ascertain whether the types of slough modification that have been proposed to date are viable. "h.The long range implications of proposed project flows vs.natural flows and potential habitat maintenance flows in terms of possible slow loss of sloughs,and loss of flushing flows.This should take -into consideration long term one dam and two dam configur- ations." The Power Authority has partially funded the U.S.Geological Survey to conduct sediment transport studies on the Susitna,Chulitna,and Talkeetna Rivers.The study will be entering its third year this year.We envision that the data from the study wi llenabl e us to model bedload and sedi- mentation processes,none of which may impact slough habitats.However, since most of the sediment contribution to the sloughs is from sources other than the Susitna,emphasis will be placed on developing flushing cri- teria.This criteria will be based on known physical relationships related to water borne transport of sediments and other pertinent data specific to the proj ect.- "i.Salmon enhancement potential above Devil Canyon without the Susitna project,with the Susitna project,and the impacts of any program to establish salmon in the upper river on existing fisheries, particularly grayling.Consideration should be given to potential conflicts between mitigation options to offset project-caused losses to grayling vs.salmon." The Alaska Department of Fish and Game's Fisheries Enhancement, Rehabilitation and Development (FRED)Division is,at the direction of the State Legislature,preparing a study which addresses this issue.We under- stood a draft study has been completed and will be finalized by February 1983. The study concludes that there is a potential for salmon enhancement in the upper Susitna drainage by either construction of a fish pass to provide for migration to the upper basin or by establishment of a hatchery.While techni- cally feasible,the fishpass scheme is not cost effective. The hatchery scenario envisions propagation of sockeye,chum,king,and coho salmon for release into Lake Louise or Susitna. The study also addresses the impact of this program on existing resident fisheries resources.Apparently,the preliminary study indication is that the impact may not be significant. "j.The potential to establish/expand the salmon fishery between the Devil Canyon and Watana dam sites in the absence of a Devil Canyon development.II There is the potential for increase of the salmon escapenent above Devil Canyon with a Watana only project.ADF&G has observed that king salmon have successfully negotiated Devil Canyon during periods of lower flows in 1982,chinook salmon spawned at the mouth of Cheechako Creek (RM 152.5),and in an unnamed creek (RM 156.8),both of which are above Devil Canyon. "k.Within and out-of-basin opportunities to offset lO~S to fisheries such as stream stockinq,lake fertilization,extens n of existing fisheries,and increasing public fishing access and portunities." Ideally,the Power Authority will try to confine mitigation for fisheries losses to within the basin.One measure that has been proposed is the stocking of barren lakes within the project area with grayling to offset losses that may be realized when tributary spawning habitat in the reservoir is inundated. Ill.Extent of dewatering between the Devil Canyon dam and its power- house and associated fishery impacts,and mitigation options.1I No flow supplementation will be provided immediately below the dam. Depending on backwater effects,this will result in a dry channel for approximately 3,300 feet below Devil Canyon dam.The gradient below the dam is quite steep and the bed is composed of coarse substrates.To provide a flow will result in insignificant fisheries habitat at a substantial capital cost. "m.Pre-and post-project nitrogen levels in Devil Canyon and impacts.II Nitrogen supersaturation is a naturally occurring phenomenon on the Susitna River.Since 1981,the Power Authority's contractors have been collecting data on gas saturation in the Devil Canyon area.Preliminary relationships have been developed that relate dissolved gas saturation to discharge and decay rates to the distance downstream from Devil Canyon. Gas supersaturation resultant of the project will be minimized by virtually eliminating spills through reservoir management.Only significant flood events (greater than a once in 50-year occurrence)would necessitate spilling over spillways.It is proposed that all other releases be through fixed cone valves,which have been shown to be effective in preventing gas supersaturation. lin.Behavioral impacts related to changes in flows,temperature,and chemical composition of the Susitna River due to the proposed project.II Behavioral response to changes in the aquatic environment will be in- vestigated in conjunction with the fisheries modeling effort. "0 •The impact of changes in winter flows,turbidity,chemical composition,salinity levels,and timing and extent of ice formation and break-up on the estuary." To date,the most intensive impact investigations have been focused on the area above Talkeetna realizing that project impacts are substantially attenuated at the estuary.However,from these investigations,a preliminary assessment of estuarine impacts have been made and are discussed in the license application.If it becomes apparent that there may be significant impacts in the estuary,these will be investigated. lip.The viability of a reservoir fishery needs to be evaluated through an assessment of:predicted reservoir temperatures,turbidity, chemical composition and anticipated primary productivity,avail- able spawning habitat,potential for establishing spawning habitat, potential for establishing spawning habitat,and the relationship of a reservoir fishery to established tributary fisheries.1I Reservoir modeling,with respect to temperature and water surface fluctuation,is currently underway.Sedimentation processes,as they relate to reservoir turbidity,have also been investigated.Current assessment in- dicates that tributary spawning habitat subject to inundation by the Watana reservoir may be lost for that purpose ..There may be changes in species composition.The Devil Canyon reservoir does appear suitable for supporting a reservoir fishery.The reservoir areas presently support grayling white- fish,longnose sucker,burbot,and Dolly Varden. "q.The timing,extent,and seasonal variability of daily peaking which would occur with either a one or two dam system and the associated aquatic impacts." It is currently proposed that Watana alone would be base loaded.With the two dam scenario,Watana would be peaked and Devil Canyon base loaded. However,consideration of peaking with Watana only should not be ruled out. To date,there has not been an assessment of aquatic impacts associated with daily peaking,we expect that,if necessary,the impacts of peaking scenarios could be investigated by means of the aquatic modeling effort. "r.Hydraulic turbine configurations with both a one and two dam configuration related to maximizing flow release options vs.more fl ex ib1e turbi ne system a1ternat ives .II The Watana plant output may vary from zero,with the units at stand- still or at spinning reserve,to approximately 1,200 MW when all six units are operating under maximum output at maximum head.The load following re- requirements of the plant results in widely varying loading but because of the multiple unit installation,the total plant efficiency varies only slightly. The Devil Canyon plant output may vary from zero to 700 MW with all four units operating at maximum output.The combined plant efficiency varies with output and number of units operating.As with Watana,the plant efficiency varies only slightly with loading due to the load following capabilities of multiple units.·. liS.The impacts of antiC"ipated operation flow release schedules on the aquatic system during a critical low water period.II It is anticipated that the project will always be operated to provide a minimum flow for fisheries.It is currently envisioned the releases will maintain Gold Creek flow at 12,000 cfs during the month of August.This is a preliminary figure and may be adjusted,along with other monthly flows, during the course of design and licensing. Terrestrial Studies Where possible,wildlife impact assessments at mitigation will be based on habitat requirements for the species in questions. In response to your point related to mitigation planning based on the National Environmental Policy Act (NEPA)guidelines,please find enclosed The Susitna Hydroelectric Project Ffsh and Wildlife Policy (1982).The policy is consistent with the NEPA hierarchic approach to mitigation of pro- j ect impacts. Your specific points related to additional terrestrial impacts and mitigation are addressed,as follows: "1.Disposal of material excavated at the Devil Canyon saddledam.1I Material excavated at the Devil Canyon saddledam will be disposed of in depleted Borrow Site G.During operations,Borrow Site G will be approxi- mately 450 feet below the pool elevation. 112.Procedures and evaluation of the potential and practicality of disturbed area rehabilitation.1I Initial procedures to rehabilitate disturbed areas are based on past experience on similar projects in Alaska and primarily confined to replace- ment of topsoil,grading,fertilization,scarification,and seeding (if necessary).It is envisioned that site specific rehabilitation effort will continue for three growing seasons.Within that period of time,there should be ample time to assess the practicality of the effort and effect necessary modification. 113.Viability of prescribed burning in the upper Susitna basin to compensate for moose habitat losses evaluated through an examin- ation of Burueau of Land Management (BlM)burns,historic burns, and enclosure studies.Potential areas of low habitat value could be enhanced through burning should be identified.Areas of interest should include sites which presently have low or declining numbers of moose and good public access,and it can be established that habitat manipulation,such as prescribed burning,would increase habitat value.1I Efforts to assess past burns,studies,and the proposed BlM Alphabet Hills burn are underway a~is the identification of sites and quantification of acreage required. 114.Anticipated project-related changes to the riparian vegetation from Devil Canyon to Talkeetna and downstream from Talkeetna should be evaluated with consideration being given to the benefits or drawbacks of accelerating,decelerating,or maintaining the existing conditions.1I These effects have been evaluated and are discussed in Chapter 3 of the license application. - 115.Temporal use of the Jay Creek Dall sheep mineral lick should be documented.The chemical composition of the mineral lick would need to be determined and identical artificial blocks set out experimentally if inundation of the mineral lick would be unavoid- able at the time it is normally used.11 Studies currently being conducted by ADF&G will determine both temporal and spatial use of the lick.Soil samples will be collected and analyzed in 1983.This information will be utilized in future mitigation planning. Aquatic and Terrestrial Studies "We recognize that on a large project such as the Susitna hydro- electric project,study components are usually compartmentalized. By this method,a complex problem becomes manageable.However,by compartmentalizing,a large burden is placed on coordination.The pieces of the puzzle must be constantly monitored to assure that they will fit together at the end of the process.We are concerned that the present system of hav.ing separate subcontractors writing the aquatic and terrestrial components of the FERC license appli- cation Exhibit E and the scheduling constraints placed upon these subcontractors will not allow for a thorough analysis of the inter- relationship of the aquatic and terrestrial studies.1I Extensive coordination activities have occurred between all contractors during preparation of the FERC license application. IlAdditional aquatic and terrestrial impacts and mitigation consider- ations should be examined. 1.Changes in the existing ice patterns and reliable predications of what these patterns would be with the project must be pro- vided to allow a full asseesment of potential impacts to the fish and wildlife resources.The following information would aid in an evaluation of project ice-related reservoir impacts. a.The timing of formation,extent,thickness,and time of breakup of reservoir ice.This would need to be related to potential wildlife reservoir crossing sites,such as Watana Creek for caribou. b.The composition and physical characteristics of the reser- voir shoreline and drawdown zones and expectations for ice shelving. The following information would aid in an evaluation of project ice-related impacts downstream from Devil Canyon: a.The timing of formation,extent,thickness,and time of breakup of ice vs.a range of water releases and winter conditions.Evaluation of thi s infonnati on should>then be directed to~ard:what would be the impact on beaver, moose,salmon utilization of the mainstream,grayling and other resident fishery use of the mainstream,the extent and impact of ice fog conditions on riparian vegetation. b.The extent to which ice functions in channel formation and modification and predicted changes in this role. c.The pre-project importance of ice as an influence in habitat changes and anti cipated post-proj ect conditi ons." The Power Authority's contractors have used state-of-the-art methodology in ice modeling studies.It is not possible,utilizing currently available technology,to supply all of the information requested.As much information as possible to predict is included in the license application.This infor- mation has been related to changes in habitat and resulting impacts to fisheries and wildlife. "2.Impacts of the proj ect on users of fi shand wil d1i fe resources, such as: a.commercial fishery use; b.big game and fishing professional guides; c.subsistence use; d.trappers; e.river guides; f.winter access across the Susitna River;and g.increased fish and wildlife user population in the railbelt." Information on b,c,d,e,and g are discussed in Chapter 5 of the license application concerning socioeconomic impacts on fish and wildlife resource users.Effects on the commercial fishery are discussed in Chapter 3; effects on winter access across the Susitna River are discussed in Chapter 2. "3.The interrelationship between potential impacts to and miti- gation options for salmon and wildlife species dependent upon aquatic habitats,such as beaver,moose,shorebirds,and black and brown bears." These interrelationships have been addressed in both the impacts and mitigation sections of Chapter 3. "4.Adjustments to the Watana reservoir fill ing schedule to minimize impacts to fish and wildlife resources such as salmon, grayling,caribou,and moose." Filling of the Watana reservoir has been scheduled to provide power by 1993.Clearing of the reservoir will be conducted in a manner and within a schedule to minimize impacts to fish and wildlife. "5.Quantification of aquatic and terrestrial habitat to be inun- dated due to the proposed dam height and what an array of lower dam heights would mean in terms of lessening habitat losses. 6.Magnitude,duration,and frequency of occurrence of daily fluctuations and their impacts on fish and wildlife resources """ .,.., with both a one and two dam system.II The above two subjects are discussed in Chapter 10 of the Exhibit E in the license application.They were also in the Development Selection Report. 117.Disposal of material excavated from tailrace and power tunnels, saddledam and general dam construction,and potential uses. 8.Impacts of the construction village,permanent village,and alternatives to the proposed system to minimize adverse fish and wildlife resources. 9.Timing restrictions to minimize adverse impacts due to access road transmission lines,and dam construction.1I These subjects are all discussed in Chapter 3 of Exhibit E of the license application. 1110.The impacts due to construction and maintenance of the trans- mission lines and access road need to be fully evaluated.This should include a complete fish and wildlife impact assessment of borrow areas and access to these sites.1I These issues have been considered and addressed in the license appli~ cation.Further consideration will be given to fish and wildlife impacts during final alignmerit of the transmission lines and access road.Restora- tion of those borrow areas above the reservoir pool will occur. 1111.Minimizing fish and wildlife impacts through proper timing of woody material removal in the impoundment areas.Consideration needs to be given to acceptable methods of disposal of this material. 12.Handling of hazardous materials to and at the construction sites and safety precautions.1I These issues are addressed in the mitigation plan of Chapter 3 of Exhi bit E. IIAlthough we are provid-ing -information which would facilitate your project objective of submitting a license application in February 1983,we continue to urge you to defer license sub- mittal at least until the 1982 field data can be fully evalu- ated.Communications between my staff and those involved in gathering data indicate that we should expect to understand much more thoroughly the resources of the Susitna study area after this year.Mitigation planning should go forth based upon this more complete understanding of the resources and the resultant assessment of proj ect impacts.II Mitigation planning will continue. September 2.1982 Mr.Claudio Arenas Planning Director Matanuska-Susitna Borough Box B Palmer.Alaska 99645 Dear Mr.Arenas:Susit"a Hydroelectric Project During the second quarter of this year.the Alaska Power Authority circulated the draft Feasibil1~Report on the Susitna Hydroelectric Project and numerous supporting documents to State.Federal and local agencies with interest in the project.This cirCulation included virtually all of the data and analysis done to that date during the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory Commission in the first quarter of 1983. During the remaining time before f111ng,the Susitna stUdy team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the project·,Environmental Report, which is the draft of the FERC license application Exhibit E,by your agency.We will be circulating the draft in mid-November of this year. After filing with and acceptance of the application by FERC.there will be another opportunity to comment on the application,including Exhibit E. At this time we would appreciate any input into the continued plan development you could provide.In particular,we-request your guidance with regard to project impacts and the mitigation opportunities your agency would recommend.These comments will be helpful both in identi- fying and addressing the most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to address these connents in the draft,it would be most helpful to have them by the first of October. As you know,the planning process is dynamic.Current efforts are focused on project access.transmission corridors and project operation alternatives.Although this information has not yet been distributed for comment,it will be included in the Exhibit E draft. - ..... F'" I September 2.19~ Mr.Claudio Arenas Page 2 We welcome your comment on all areas of the project.but.in accordance with Section 4.41 of the FERC regulations,we are particular- ly interested in your comments with regard to land use and socio- economic issues~In these areas.we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your continued support and participation in the development of the Susitna project license application is greatly appreciated. Ve~truly yours, S\GNED Eric P.Yould Executive Director EPY:mb cc:Mr.J.Hayden September 2.1982 Director of Planning Fairbanks-North Star Borough 520 5th Avenue P.O.Box 1267 Fairbanks.Alaska 99701 Dear Sir:Susitna Hydroelectric Project During the second quarter of this year.the Alaska Power Authority circulated the draft Feasibility Report on the Sus1tna Hydroelectric Project and numerous supporting documents to State.Federal and local agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study.Currently.efforts are proceeding towards completing the first phase of planning efforts and submitting.license application to the Federal Energy Regtllatory COIID1ss1on in the first quarter of 1983. .During the remaining time before filing.the Sus1tna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the project's Environmental Report. which is the draft of the FERC license application Exhibit E.by your agency.We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC,there will be another opportunity to comment on the application.inclUding Exhibit E. At thh time we would appreciate any input into the continued plan development you could provide.In particular.we request your guidance with regard to project impacts and the mitigation opportunities your agency would recomend.These CODIJIents will be helpful both in identi- fyi ng and addressing the most important areas of concern in the next draft Exhibit E ind in documenting agency comments and recommendations before FERC.In order to address these comments in the draft.it would be most helpful to have them by the first of October. As you know,the planning process is dynamic.Current efforts are focused on project access,transmission corridors and project operation alternatives.Although this infonmationhas not yet been distributed for comment,it will be included in the Exhibit E draft. - September Z.is D1rector of Plann1ng~Fa1rbanks-North Borough Page 2 We welcome your comment on all areas of the project,but,in accordance with Section 4.41 of the FERC regulations,we are particular- ly interested in your comments with regard to socioeconomic issue.In these areas,we would like to address your concerns on potential impacts and mitigatiQn measures which can be included in project plans. Your continued support and participation in the development of the Sus1tna project license application is greatly appreciated. Very truly yours, SIGNEfF-- Eric P.Yould Executiye Director EPY:1IIb ) cc:Mr.J.Hayden ~-------------------~--__-------------- Mr.John E.Cook Regional Director Alaska Region National Park service 450 West 5th AVMaue Anchorage.Alaska 99501 Dear Mr.Cook: September 2.1982 Sus1tna Hydroelectric Project During the second quarter of this year.the Alaska Power Authority circulated the draft Feasibility Report on the Susitna Hydroelectric Project and numerous supporting documents to State.Federal and local agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date 4uring the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the federal Energy Regulatory Commission in the first quarter of 1983. During the reMaining time before filing.the Sus1tna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the project's Environmental Report, which is the draft of the FERC license application Exhibit E.by your agency.We w111 be circulating the draft in mid-November of this year. AFter filing with and acceptance of the applicati~n by FERC.there will be another opportunity to comment on the application,including Exhibit E. At this time we would appreciata any input into the continued plan development you could provide.In particular,we request your guidance with regard to project impacts and the mitigation opportunities your agency would recommend.These comments will be helpful both in identi- fying and addressing tbe most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to address these comments in the draft,it would be most helpful to have them by the first of October. As you know.the planning process is dynamic.Current efforts are focused on project access,transmission corridors and project operation alternatives.Although this information has not yet been distributed for comment,it will be included in the Exhibit E draft. - - ..... - September 2,l~, Mr.John E.Cook Page 2 we welcome your COIlIII8nt on all areas of the project,but.in accordance with Section 4.41 of the FERC regulations,we are particular- ly interested in your comments with regard to historical and archeological s recreation,aesthetics,and resources.In these areas, we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your cont1nued support and participation fn the development of the Sus1tna project license appl1cat1on 1s greatly appreciated. Very truly YOUI"S, S!......,,·,~'""\ Il;f,,~_) Eric P.Yould Executive Director EPY:mb cc:Mr.J.Hayden Mr.Larry Wright September 2,1982 At this time we would appreciate any input into the continued plan development you could provide.In particular,we request your guidance with regard to project impacts and the mitigation opportunities your agency would recommend.These comments will be helpful both in identi- fying and addressing the most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to address these couments in the draft,it WCltIld be most helpful to have them by the first of October. As you know,the planning process is dynamic.Current efforts are focused on project access,transmission corridors and project operation alternatives.Although this information has not yet been distributed for comment,it will be included in the Exhibit E draft. During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the Sus1tna Hydroelectric Project and numerous supporting documents to State,Federal and "local agencies with interest in the project.This circulation included. virtually all of the data and analysis done to that date during the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory Commission in the first quarter of 1983. During the remaining time before filing,the SUs1tna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting anotber review of the project's Eny1ronmental Report~ which is the draft of the FERC license application Exhibit E,by your agency.We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC,there will be another opportunity to comment on the application,including Exhibit E.. Colonel Neil E.Saling District Engineer.u.s.Army Corps of Engineers P.O.Box 7002 Anchorage,Alaska 99510 Dear Colonel Saling~Susitna Hydroelectric Project r--' f.iiW'I'.... I I - -- .- ,.... - September 2,l~~ Colonel Nen Sal1ng Page 2 We welcome your comment on all areas of the projeet,but,in accordance with Section 4.41 of the FERC regulations.we are particular- ly interested in your conments with regard to water quality.In these are~s,we would like to address your concerns on potential impacts and mitigation measures which can be ihcluded in project plans. Your cont1nued support and participation in the development of the SUs1tna project license application is greatly appreciated. Very truly youn t SIGNED Eric P.Yould Executive D1recto~ EPY:mb cc:Mr.J.Hayden September 2,1982 District Chief U.S.Geological Survey 1515 E.13th Avenue Anchorage,Alaska 99501 Dear Sir:SusitRa Hdyroelectr1c Project During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the Sus1tna Hyrdoelectric Project and supporting documents to State,Federal and local agencies with interest in the project.This circulation included Virtually all of the date and analysis done to that date during the study.Currently, efforts are proceeding towards completing the first phase of planning efforts and subm1tting a license application to the Federal Energy Regulatory COIIIB1ss1on in the f1 rst quarter of 1983. During the remaining time before f11ing.the Susitna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for the project impacts.This effort will include requesting another review of the project's Environmental Report,which is the draft of the FERC license application Exhibit E,by your agency.We will be circulating the draft 1ft mid-November of this year.After filing with and acceptance of the application by FERC t there will be another opportunity to comment on the applicat10n l includ- ing Exhibit E. At this time we would appreciate any input into the continued plan development you could provide based on the materials which you have received.These comments will be helpful both in identifying and addressing the most important areas of concern in the next draft Exhibit E.Your continued support and participation in the development of the Susitna project license application 1s greatly appreciated. Very truly yours I .SIGNED Eric P.Yould Executive Director cc:John Hayden September 2.1982 Ms.Wendy Walt Office of Coastal Management Division of Policy Development and Planning Pouch AP Juneau.Alaska 99811 Dear Ms.Wolt:SUI1t".Hdyroelectr1c Pro~ -! .- - - .During the second quarter of this year,the Alaska Power Autbor1ty circulated the draft Feasibility Report on the Susitna Hyrdoelectric Project and supporting documents to State,Federal and local agencies witb interest in the project.Th1scirculat1on included virtually all of the date and analysis done to that date during the study.Currently. efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal.Energy Regulatory Commission in the first quarter of 1983. During the remaining time before filing,the SU5itna study team will be refining the plans presented earlier this year and contfnuing to evolve proposed mitigation plans for the project impacts.This effort will include requesting anothe,..review of the project's Environmental Report,which is the draft of the FERC license application Exhibit E.by your agency.We will be circulating the draft in mid-November of this year.After filing with and acceptance of the application by FERC • there will be another opportunity to comment on the application.includ- ing Exhibit E. At this time we would appreciate any input into the continued plan development you could provide based on the materials which you have received.These coaaents will be helpful both in identifying and addressing the most important areas of concern in the next draft Exhibit E.Your continued support and participation in the development of the Sus1tna project license application is greatly appreciated. Very truly yours, SIGNED Eric P.Yould Executive Director cc:John Hayden September 2,1982 Mr.David Haas State-Federal Ass1stan~e Coordinator State of Alaska Office of the Governor Division of Policy Development and Planning Pouch AW Juneau,Alaska 99811 Dear Mr.Haas:Susitna Hdyroelectric Project During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the Susitna Hyrdoelectr1c Project and supporting documents to State,Federal and local agencies with Interest in the project.This circulation included virtually all of the date and analysis done to that date dur1ng the study.Currently, efforts are proceeding towards completing the first phase of planning efforts and submitting a license applfcation to the Federal Energy Regulatory Coumiss1on 1n the first quarter of 1983. Dur1ng the remaining tillle before f111ng.the Sus1tna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans fnrthe project impacts.This effort . will include requesting another review of the project's Environmental Report,which is the draft of the FERC license application Exhibit E,by your agency.We will be circulating the draft in mid-November of this year.After filing with and acceptance of the application by FERC. there will be another opportunity to comment on the application.includ- ing Exhibit E. At this time we would appreciate any input into the continued plan development you could provide based on the materials which you have received.These cements will be helpful both in identifying and addressing the IIIOst important areas of concern in the next draft Exhibit E.Your continued support and participation in the development of the Sus1tna project license application is greatly appreciated. Very truly yours. SiGNED Eric P.Yauld Executive Director cc:John Hayden September 2,1982 Mr.Richard J.Vern1men Acting District Manager U.S.Bureau of Land Management 4700 E.72nd Avenue Anchorage,Alaska 99507 Dear Mr.Yernimen:Susitna Hydroelectric Project - - ..... During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the Susitna Hydroelectric Project and numerous supporting documents to State.Federal and local agencies with interest in the project.This circulation included virtually all of the data and analysis done to.that da'te during the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory Ca.1ss10n in the first quarter of 1983 .. During the remaining time before filing,the Susitna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the projectts Environmental Report, which is the draft of the FERC license application Exhibit E,by your agency..We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC,there will be another opportunity to comment on the application.including Exhibit E. At this time we would appreciate any input into the continued plan development you could provide.In particular,we request your guidance with regard to project impacts and the mitigation opportunities your agency would recommend.These comments will be helpful both in identi- fying and addressing the most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to address these cOlllllents in the draft,it would be most helpful to have them by the first of October. As you know,the planning process is dynamic.Current efforts are focused on project access,transmission corridors and project operation alternatives.Although this information has not yet been distributed for comment,it will be included in the Exhibit E draft. September 2,1£. Mr.R1chard J.Yern1men Page 2 We welcome yeur cOtmient on all area$of the project il but,in accordance with Section 4.41 of the fERC regulations,we-are part1cular- ly1nterested in your comments with regard to land use and aesthetics~ In these areas,we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your continued support and participation in the development of the Sus1tna project license application is greatly ~ppreciated. Very truly yours, SIGNED Eric P.Yould Executive Director EPY~mb cc:Mr.J.Hayden Mr.John Rego - September 2,1982 Mr.John R.Spencer Regional Administrator Region X U.S.EnYironmental Protection Agency 1200 6th Avenue Seattle,Washington 98101 During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the Sus1tna Hydroelectric Project and numerous supporting documents to State,Federal and local agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory COIIIIission in the first quarter of 1983. During the remaining time before filing,the Susitna study team will be refining the plans presented earlier this year and continuing to evolve proposed mitigation plans for-project impacts.This effort will include request1nganother review of the project's Environmental Report. which is the draft of the FERC license application Exhibit E.by your agency.We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC,there will be another opportunity to comment on the application,including Exhibit E. - - Dear Mr.Spencer:Sus1tna Hydroelectric Project -At this time we would appreciate any input into the continued plan development you could provide.In particular,we request your guidance with regard to project impacts and the mitigation opportunities your agency would recommend.These comments will be helpful both in identi- fying and addressing the most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to address these comments in the draft,it would be most helpful to have them by the first of October. As you know,the·planning process is dynamic.Current efforts are focused on project access,transmission corridors and project operation alternatives.Although this information has not yet been distributed for comment,it will be included in the Exhibit E draft. September 2.h_~ Mr.John R.Spencer Page 2 We welcome your comment on all areas of the project.but.in accordance with Section 4.41 of the FERC regulations.we are particular- ly interested in your connents with regard to water quality.In these areas.we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your continued support and participation in the development of the Sus1tna project license application is greatly appreciated. Very truly yours. stG~NH:D '1","1 - Eric P.Yauld Executive Director EPY:mb cc:Mr.J.Hayden Mr.William Riley Mr.William Lawrence - September 2.1982 Mr.Ernest W.Mueller,Commissioner Department of Environmental Conservatfon Pouch 0 Juneau,Alaska 99811 Dear Commissioner Mueller:Sus1tn.Hydroelectric Proj~ During the second quarter of this year,the Alaska Power Authority circulated the draft Feasibility Report on the SUs1tna Hydroelectric Project and nUilerous supporting documents to State,Federal and local Igencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory Connission 1n the first quarter of 1983. During the remaining time before fi11ng.the Sus1tn.stUdy team will be refining ~he plans presented earlier this year and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the projectts Environmental Report. which 1s the draft of the FERC license application Exhibit E.by your agency.We will be circulating the draft in 8id-November of this.year. AFter f111ng with and acceptance of the application by FERC.there will be another opportunity to comment on the application.inclUding Exhibit E. At this time we would appreciate any input into the continued plan development you could provide.In particular.we request your guidance with regard to project impacts and the mitigation opportunities your agency would recoanend.These ccaBents w111 be helpful both in identi- fying and address1ngthe most important areas of concern in the next draft Exhibit E and in documenting agency comments and recommendations before FERC.In order to'address these cOIIIDenu in the draft.it would be most helpful to have them by the first of October. As you know,the planning process 1s dynamic.Current efforts are focused on project access,transmission corridors and project operation alternatives.Although this fnfomation has not yet been distributed for comment,it will be included in the Exhibit E draft. September 2..1!t...,- Commissioner Ernest W.Mueller Page 2 We welcome your connent on all areas of the project,but,in accordance with Section 4.41 of the FERC regulations,we are particular- ly interested in your comments with regard to fish,wildlife and habitat.In these areas,we would like to address your concerns on potential impacts and mitigation measures which can be included in project plans. Your continued support and participation in the development of the Sus1tna project license application is greatly appreciated. Yery truly yours, SIGNED Eric P.Yould Executive Director EPY:mb cc:Mr.J.Hayden Mr.Robert Martin " ...., ..... - .-. '"'" - - - - september Z,1982 Mr.Michael Meehan,Director Planning Department Municipality of Anchorage Pouch 6-650 Anchroage.Alaska 99502' Dear Mr.Meehan:Sus1tna Hydroelectric Project During the second quarter of this year,the Alaska Power Authority circulated·the draft Feasibility Report on the SUs1tna Hydroelectric Project Ind numerous support1 ng documents to State II Federa 1 and 1oca 1 agencies with interest in the project.This circulation included virtually all of the data and analysis done to that date during the study •.Currently,efforts are proceeding towards completing the first phase of planning efforts and submitting a license application to the Federal Energy Regulatory Commission in the first quarter of 1983. During the remaining U.before f111ng,the Susitna study team will be refining the plans presented earlier thisyelr and continuing to evolve proposed mitigation plans for project impacts.This effort will include requesting another review of the project's Environmental Report, Which is the draft of tJ1e FERC license appHcat10n Exhibit E,by your agency.We will be circulating the draft in mid-November of this year. AFter filing with and acceptance of the application by FERC~there will be another opportunity to comment on the application,including Exhibit E. At this time we would appreciate any input into the continued plan development you could provide~In particular.we request your guidance with regard to project impacts and the mitigation opportunities your agency wou 1d recoamend.These coments wi 11 be he1pfu 1 both in i dent1- fying and addressing the most important areas of concern 1n the next draft Exhibit E and in documenting agency comments and recommendations before FERt.In order to address these cODIRents in the draft,it would be lICIt helpful to have them by the first of October. As you know,the planning process is dynamic:.Current efforts are focused on project access.transmission corridors and project operation alternatives.Although this information has not yet been distributed for cemment,it will be included in the Exhibit E draft. September 2,1982 Mr.Michael Meehan Page 2 we welcome your cODll1ent on all areas of the project,but,in accordance with Section 4.41 of the FERC regulations,we are particular- ly interested 1n-your CORIIJents with regard to soc1o-econOllic issues.In these areas,we would like to address your concerns on potential impacts and mitigation Measures which can be included in project plans. Your continued ~upport and participation in the development of the Susitna project license appl1cat10n is greatly appreciated. Very truly yours. ·S\GNID Eric P.Yould Executive Director EPY:1IIb cc:Mr.J.Hayden i: 1,l ..i ;.. JA r s.HAMMONO,GOVERNOR Associates 333 RASPBERRY ROAD ANCHORAGE,ALASKA 99502 344-0541 September 10,1982 Dr.Robin Sener LGL,Alaska Research 1577 C Street Anchorage,AK 99501 ce.:S.FA~c..Y I<.E.'-'e.e 1T-r /eSSA 1:.ELLa SDtJ I kJEl-lrr ~d:'lif5~·rlPf,f!.~~;"'------'~.~!:'::U~~~·....w ..._RE eEl V ED SEP 13 1982 LG L ALASKA - Dear Robin, Since I was one of the more vocal participants at the recent Adaptive Environmental Assessment workshop and was responsible for deviations from the original agenda,I thought it would be useful if I summarized my impressions of the workshop.Some background on my experience and the history of the Susitna Project wildlife studies may be helpful in understanding my perceptions. I have been involved in a number of impact assessment programs in Alaska.Some of these such as the nuclear testing at Amchitka Island, the Trans-Alaska Pipeline and the Outer Continental Shelf Environ- mental Assessment Program were fairly large programs.In most cases interdisciplinary coordination among field studies was poor or after the fact.Impact statements were prepared by people who had no input into the field studies and either didn't understand the studies or received the results too late or in a form they couldn't use.The result was that decisions were made \"Tith inadequate environmental in- put,even though hugl:::amounts of money were spent. I became involved in the Susitna Proj ect when the Corps of Engineers rl:::-activated the project in 1974.Planning was poor and funding i1lad- equate.As a result,ill 1977,ADF&G unilaterally drew up a plan of study listing a ilUITiDl'.r of specific projl.::.cl:s and pointing uur thl:\l(;:cd for interdisciplinr.iry coordl.nation J pCircicularl)''t'>c.Li-ieel1 fish,wild- life,vegetation,hydrology,recreation,and socia-economic studies. Many of the specific projects listed were incorporated in Acres'POS in fall of 1979.huwever much of the interdisciplinary coordination failed to materialize.I repeatedly asked TES to provide this coordi- nation and develop an overall study design that wOBld integrate wild- life and vegetation studies and ensure collection of adequate hydro- logy and climate information.When no concrete action was taken,we made a number of requests for changes ill plant ecology and clirllate Dr.Robin Sener 2 September 10,1982 studies,more or less guessing what would ultimately be needed.We asked that a workshop of outside experts be held to review the plant ecology studies.We were told that these things would be taken care of in Phase II.We started holding meetings on our own to try to re- solve these problems and even attempted to design vegetation and snow sampling schemes that we could implement ourselves.Most of these efforts failed due to lack of money,manpower and expertise. In spite of these problems,I believe the program has been more suc- cessful in identifying impacts and providing environmental input into the decision making process than any other,program of similar size in which I have been involved.However I felt we'could do much better. Things began to improve as we got into Phase II planning,but the planning process wasn't well organized and a number of aspects,espe- cially those related to habitat,had not been fully resolved.It was at this point that LGL joined the project and proposed use of the AEA simulation modelling process.The workshop was the first major step in that process.While the stated objective of the AEA workshop was to develop a working model,I viewed it as a potential good first step in a systematic planning process that was badly needed regardless of whether simulation modelling is used.The model itself helped to fo- cus the workshop,but I had some deep concerns about the modelling process as it was outlined. The following is a partial list of issues I hoped would be addressed during the workshop and subsequent meetings. 1.Design a coordinated,interdisciplinary approach to assessing impacts on wildlife.This would provide a framework for identi- fying information needs and help ensure that all the pieces of information needed for a comprehensive impact assessment are col- lected in a form that is useable. 2.Initiate a process for reviewing the design and methodology of the plant ecology studies.The plant ecology people have re- ceived inadequate input from individuals conducting wildlife studies and the wildlife impact assessment.There have been con- cerns about the usefulness of some of the information collected in Phase I.We need to clarify what we want. 3.Select a habitat based approach for measuring impacts.Hany of us have reservations about REP.We needed to develop a better approach that achieved the same objectives. 4.Review on methods of handling data.We had discussed the value of using a geoprocesser for analyzing data.We needed to decide how certain types of data would be used before we could weigh costs against benefits. 5.Identify products and a timetable for ADF&G's Phase II contract. The reporting schedule in our contract became obsolete with the submission of our Phase I report. Dr.Robin Sener 3 September 10,1982 6.Provide fresh viewpoints from individuals outside of the project. We have always been at our best when we had outside people chal- lenging our ideas and injecting new lines of thinking. 7.Develop good working relationships.There has been a tremendous turnover in personnel in several of the participating groups.It is essential that good communications and cooperation be main- tained.We had already had one counterproductive incident. It has been my experience that workshops are pIe to develop good working relationships. spect for each other and an appreciation for good forums for peo- People develop re- the points of view. The following are some of the concerns I had about the planned model- ling process. - - 1.The quality of the model could be poor.With the short time frame,the lack of familiarity of the project by the modellers and many other workshop participants,the geographic remoteness of the modellers from the investigators after the workshop,and the lack of a specific commitment for follow up workshops,the model could end up poorly designed and filled with inadequately scrutinized data.This could lead to serious errors that would never be corrected.I felt the project warranted a more deliber- ate,thoughtful approach. 2.Use of a canned modelling process could result in fitting the project to the model,rather than vice versa.Any process de- signed to be quickly applied.to a wide variety of situations is likely to be less desirable than one tailored specifically to the objectives of a single project. .- - 3. 5. The model could be misused.Models can be useful tools for test- ing ideas and examining potential relationships.However,what comes out of them is no better than what goes into them.Our knowledge of natural systems is inadequate for developing models that can make accurate predictions.The outputs need to be care- fully scrutinized with full consideration of the assumptions and potential biases and errors that went into the model.I am aware of numerous cases where predictions have been blindly accepted, even by people who developed the model and should know better.I felt that the superficial treatment a model would receive in a one week workshop,combined with the tight FERC license applica- tion schedule,could lead to improper use of a very poor model. The rush to have a running model by the end of a week could waste time that should be spent on planning and coordination.The schedule of the workshop dictated that people spend time digging out data.I felt this time should be spent on designing the model and interactions between people from different disciplines. It is unusual to get such a broad spectrum of expertise together Dr.Robin Sener 4 September 10,1982 and I didn I t want to waste the time.'Digging out data can be better handled in small groups back at their offices. 6.The modelling process could divert attention from important im- pact issues.Modelling can be a very seductive process.Even skeptics can become so involved that they fail to step back and look at the entire picture.The mOdel will address only some impact mechanisms for some species.There are many issues that the model will not address or will address only indirectly.If the model consumes too much attention these issues could be ig- nored. The work shop addressed all of the issued I listed above.Some of the issues were treated only indirectly and superficially,but this was to be expected from such a large,diverse group.Overall the workshop was a very good first step.Substantial progress was made in designing an interdisciplinary approach to impact assessment.Plans were made for a subsequent meeting to review plant ecology studies. The models seem to provide a basis for a habitat based assessment while avoiding some of the problems with HEP.Once decisions are made on how habitat data will be used,we should be able to evaluate geoprocessing as a tool.I came out of the workshop with a clearer idea of what products LGL wants from ADF&G and plans were made to firm things up over the next couple of weeks.The infusion of fresh view- points was excellent and I think a good basis for future working rela- tionships was formed. My concerns about the modelling process itself remain.They were somewhat alleviated for the time being by the fact that LGL personnel seem to share some of my concerns.If we develop the models care- fully,and use them properly they can be useful tools.However if we fail to document and continually remind ourselves of the assumptions and biases built into the models,if we allow ourselves to think of the model as an accurate representation of the real world,or if we fail to address impact issues not covered by the model,then the model could do more harm than good.It would be helpful if we drew up a complete list of potential impact mechanisms for each species.We should get input on this list from as many people as possible to en- sure that all the issues are on the table.Then we can identify an approach to assessing each impact mec~anism.Some issues can be ad- dressed by the model and some may require a unique study design.This list would help keep us on track and put the model in proper perspec- tive. Dr.Robin Sener 5 September 10,1982 - ~, ""'" - In summary,I was very satisfied with the workshop as a first step in a planning process.The canned AEA modelling process was tempered by LGL's awareness that the workshop had broader value than simply con- structing a working model..If we continue the process with smaller more specialized meetings and lots of communication between groups,as you outlined in your closing statement,we snould end up with a good impact assessment and a useful basis for mitigations planning. Sincerely, ~:':er cc:Richard Flemming,APA IN REPLY REFER TO: WAES United States Department of the Interi9f FISH AND WILDLIFE SERVICE 1011 E.TUDOR RD. ANCHORAGE,ALASKA 99503 (901)216-3800 24 JAN 1983 Eric P.Yould,Ex~utive Dir~ctor Alaska Power Authority 334 West 5th Avenue Anchorage,Alaska 99501 Dear Mr.YouM: The fish and Wildlife service {fWS),as part of our overall participation in planning for and evaluating the feasibility of the ~usitna hydroelectric project,has determined project area Resource Categories and corresponding mitigation goats.This ~as been~e,1n accordance with the fWS Miti9ation Policy {fR Vol.46,No.15,23 January 1981)and in consultation and coordination with the National Marine fisheri~s Service,the Environmental Protection Agency and the Alaska Department of Fish and Game.Both agencies agree that it is appropriate and timely that guidance be provided for miti9ation planning for the Susitna Hydr{)electric Project. The Alaska Department of fish and Game had specific comments that have been addressed.They did point out that from the state or ecoregion basis,the, habitat of al1 evaluation species is abundant.We agree,but have concluded that the habitat for those species listed in Resource Category 2 is scarce or becoming scarce,considering its historical quantity and quality from the national perspective. Principles of the FWS Mitigation Policy Four Resource Categories are described in the FWS Mitigation Policy,with corresponding mitigation planning goals of decreasing stringency.Designation of project area fish and wildlife habitat in Resource Categories serves as a guide to insure that the level of mitigation recommended by FWS will be consistent with the fish and wildlife resource values involved.It is within this framework that the FWS will evaluate project impact and formulate mitigation recommendations.Table 1 summarizes FWS Mitigation Policy Resource categories and their goals. ..... - - - Resource category 1 2 3 4 Table 1.Resource Categories and Mitigation Planning Goals Designation criteria Habitat to be impacted is of high value for evaluation species and is unique and irrepl ac-.eab leon a nat iona 1 basis or in the ecoregion section. Habitat to be impacted is of high value for evaluation species and is relatively scarce or becoming scarce on a national basis or in the ecoregion section. Habitat to be il'l'lpacted is of high to medium value for evaluation species and is relativelY abundant on a national basis. Habitat to be impacted is of rnediumlto low value for ~valua~ion species. Mitigation planning goal No loss of existing habitat value. No net loss of in- kind habitat value. No net loss of habitat value while minimizing loss of in-k'in<l habitat value. Minimize loss of habitat value. - Taken from FWS Mitigation Policy (FR Vol.46,No.15,23 January 1981). Focus of the FWS Policy on Habitat Value Specific guidance the FWS wishes to provide is in mitigating losses of habitat value.Predicted carrying capacity or population data by themselves are often unreliable indicators for evaluating project impacts upon fish and wildlife resources.Causes include sampling errors,cyclic fluctuations,and poorly defined life requisites for the species involved.Therefore,the FWS feels that habitat value,based upon predicted carrying capacity,current and historical use,and consideration of the influence of disturbance on capability of the habitat to support fish and wildlife populations,is the appropriate concept to be used in determining mitigation requirements. Although the primary focus is on fish and wildlife habitat value losses,the polic.v covers impacts to fish and wildlife populations and the human uses thereof.In many cases,compensation of habitat value losses should result in replacement of fish and wildlife populations and human uses.But where it ~es not,~fle service will recommend appropriate additional means and measures. hs stated in the FWS Mitigation Policy,specific ways to achieve the mitigation goal when loss of habitat value is unavoidable include,-(1) physical modification of replacement habitat"to convert it to the same type lost;(2)restoration or rehabilitation of previously altered habitat;(3) increased management of similar replacement habitat so that the in-kind value of lost habitat is repla~ed,or (4)a combination of these measures.By r~placing habitat value losses with similar habitat values,populations of sp~ies associated with that habitat may remain relatively stable in the area over time.II The mitigation goal of in-kind replacement of lost habitat is not always achievable.~urther,opposition to a project on that basis alone may not be warranted.In ~uch cases there are two instances when deviation from this goal is appropriate.These ar·e:-When (l)different habitats and species available for replacement are determined to be of greater value than those lost,or (2)in-kind replacement is not physicallY or biologically attainable in the .ecoregion section.In either case,replacement involving different habitat kinds may be recommended provided that the total value of the habitat lost is recol11llendedfor r.ept acement.II Evaluation Species Determination of Resource (ategories is based upon the habitat value and relative abundance of species selected for evaluation.The choice of evaluation species will,ultimately,have a prominent role in determining the ~tent and type of mitigation achieved in a project. fwo basic approaches to selecting project impact evaluation species~an be tai<en.first,speci-es with high pub 1 i.e interest,subs istence or ~onomic value may be 5elected.The second approach would entail the selection of species which would provide a broader ecological perspective of an area.In actual practice,~pecies are selected to represent social,economic, subsisten~e and broad ecological aspects. It should be recognized that the evaluation species will,to a large extent, define the geographic scope of both the direct and indirect fish and wildlife resource impacts resulting from a project.Direct impacts to species such as chinook salmon,brown bear,and caribou can have indir~t impacts to others with wh ich they have an interdependent rehtionsh ip. Nineteen species have been selected by the fWS to determine the habitat mitigation Resource Categories for the Susitna Hydroelectric Project (Table 2).We consider these species as having high Dublic interest,economic and/or subsistence value,and ecological significance!l.Brief descriptions of these species as they relate to the project are provided in the Appendix. The species selected to establish the habitat mitigation Resour-ce Categories need not completely correspond to the list of species -chosen to quantify project impacts and mitigation.The species selected for impact assessment and miti~ation planning by the APA,through its consultants,and coordinated with 11 The Bald Eagle meets several of these tests but was not included as an evaluation species for mitigation purposes because it is specifically protected by the federal Bald Eagle Protection Act~ I~ the resource agencies,includes all of the FWS evaluation species.Study of those species other than the FWS evaluation species should continue since they provide confidence in predictions of project impacts and potential mitigation alternatives.For example,consi~eration of high public interest and economic value led to the selection of the golden eagle and the pine marten as evaluation species.However,our ability to directly monitor project impacts through these species is questionable.Monitoring of small mammal and songbird populations dependent upon forested habitat,lends additional confidence to predictions of i_l11 l?act on the ~va1uation species. Resource ~ategory Determination The resource category determination was made by the-fllS in consideration of the relative abundance on a national basis of the evaluation species habitat and the value of ~neir habitat to be impacted in the pre-project status. For purposes of ~his document the area of direct project impact is defined as the ar~a to be disturbed or inundated by project features such as the dams, reservoirs,ac-cess roads and -transmission line;the nood plain of the Susitna River from the lower ~am to Talkeetna;and the riparian area below Talkeetna. Spec'f.es using each area are directly impacted.Species dependent on directly impacted species ar~indirectly impacted. The criteria used for determining evaluation species habitat relative scarcity or abundance from ~he national perspective are:(a)the histori-cal range and habitat quality of the evaiuation species,and -(b)the status of that habitat today.If a significant reduction in extent or quality of habitat has occurred for an evaluation species,that habitat is considered scarce or becoming scarce.If that is not ~he case,~he habitat is considered abundant. The lack of ecosystem diversity in arctic and subarctic environments is widely recognized (Kormandy 1969,Whittaker 1975).losses to one species will quickly reverberate through the ecosystem due to lower stability found in less diverse ecosystems (Kormandy 1969).Buffering of adverse impacts upon one species by others does not occur to the extent found,for instance,in the tropical and temperate zones.for example,losses to moose will lead to increased predation pressure on caribou eventually leading to reductions in populations of caribou,wolves,black bears,and brown bears. Most of the evaluation species (e.g.,moose,caribou,wolf,Da11 sheep,brown bear,black bear,and the five salmon species)are dependent upon large habitat areas as well as upon specific habitat types which receive seasonal use.This necessitates long term monitoring and causes difficulty in clearly evaluating impacts and formulating mitigation measures.As a result, seemingly minimal habitat losses could severely impact a population throughout the upper Susitna basin. 'The FWS has placed the habitat of the evaluation species in the following resource category designations Y: Resource Category 2 -Caribou -to Brown bear Gray wolf "'"Ch inook salmon '-Coho salmon "Chum salmon Resource category 3 Moose Dall sheep Arctic grayling Black bear Beaver Pine marten Golden eagle Trumpeter swan Sockeye salmon Pink salmon Rainbow trout Burbot Resource Category 4 Dolly Varden Y Once the vegetative cover types have been delineated and evaluated as habitat for these evaluation spec;'es,r.esource category determinations can be made by~over type.In instances where evaluation species habitat overlap,the most conservation (highest)Resource Category will determine ~WS mitigation goal for that area. The fWS provides this analysis to further Susitna Hydroelectric Project planning.By establishing project and species habitat SPeCific mitigation goals theFWS intends to protect and conserve the ~ost important and va~uabte fish and wildlife resources while facilitating balanced development of the Nation's natural resources. Sincerely. Acting Assistant Director Table 2.fish and Wildlife Service Mitigation Evaluation Species for the Susitna Hydroelectric Project. - - COll1I1on Name Moose Caribou Brown bear Bl ack bear 'Gray wolf Dall sheep Beaver Pine marten Golden eagle Trumpeter swan Chinook salmon Coho salmon Sockeye salmon Chum salmon Pink salmon Arctic grayl ing Rainbow trout Do llyVarden Burbot Scientific Name Alces alces Rangifer tarandus Orsus arctosu.americanus -canis lu~us Ovis dati taStor canadensis Martes americana Aquilachrysaetos Cygnus buccinator Oncorhynchus tshawytschao.kisutch IT.nerkao.ketao.gorouscha Thymallus arcticus Salmo sairdneri sa1vellnus malma Lota lota Literature Cited Kormondy,E.J.1969.Concepts of Ecology.Prentice-Hall,Inc.Englewood Cliffs,New Jersey Whittaker,R.H.1975.Communiti~s and Ecosystems.2 nd Ed.Macmillan Publishing Co.,Inc.New York,New York. - - - Appendix.Susitna Hydroelectric Project Evaluation Species Terrestrial Species 1.Moose (Alces alces).In terms of hunting pressure,moose are probably thE most important big game species in Alaska.Historically,moose were an important source of food,clothing,and implements along the major rivers.On a local,regional,and state-wide basis,this species cont'iOl:Jes to be an important source of food and recreation.---The monetary value of moose is compounded by the number of non-resident hunters which are attracted to the state.Spending by hunters results in benefits throughout the State's economy.Moose also have a high non-consumptive value.They are easily observed and thus provide high photographic value. In terms of sus~ptabi1ity to project impacts moose provide a good evaluation subject.Commonly associat~d with riparian zones,especially during harsh winters,moose will be adversely impacted by the project. Yet,because moose are generally responsive to habitat modifi~ations, post-project habitat manipulations could potentially benefit moose. Information on moose,both in t~rms of general life history and project area specific data is comparatively good.With continued project-sponsored monitoring of the area populations,adequate information will,eventually,be available for mitigative planning. Moose play an important ecological role in the project area.They are an important prey species for wolf (Canis lupus),black bear (Ursus ameri~anus),and brown bear (U.arctos).In addition,predation on moose may provide caribou (Rangifer-taranaus)with some relief from pr~dation. The moose population and habitat quality downstream of the impoundment areas is relatively high (~bdafferi 1982).Upstream of the Devil Canyon dam site the population level could be described as low to moderate (Ballard et al.1982a).It has been suggested that predation is . restricting population growth in the upstream area (Ballard et a1.1982). Moose habitat,relative to its historical range,is considered abundant from a national and ecoregion section basis. 2.Caribou (Rangifer tarandus).Caribou have traditionally been and still are an important food source for humans on a local,regional,and state basis.As a favored game animal,caribou attract many resident and non-resident hunters.Benefits accrue throughout the State's economy as a result of these hunters. The project area is within the range of the Nelchina herd.The herd contains approximately 20,000 animals and js of very high value to resident hunters because of its size and proxigity to population centers. The herd contained 60,000+animals during the 1960·s.£aribou habitat, from the national perspective,has not been significantly reduced from its histor~a1 range,However disturbances such as highways,pipelines,North Slope Oil field activities and human/equipment presence have cumulatively threatened the quality of caribou habitat statewide.Accordingly,we consider caribou habitat of historical quality is becoming scarce. The herd has been continuouslY studied since around 1948 (Pitcher 1982). Intensified investigations,through radio-tracking,are being carried out as a component of the Susitna Hydro Big Game Studies undertaken by Alaska Department of Fish and Game (ADF&G)(Pitcher 1982).Management of the caribou herds is aimed at balancing population levels with their habitat and avoiding the sharp fluctuations in numbers that have previously characterized the herds. Migratory behavior by <:aribou limits this prey speci-es to an ephemeral role to its somewhat more sedentary predatory species;wolf,and black and brown bear.Caribou do not provide a dependable year-round food source. Just as caribou would provide relief from predators for moose,the reverse would also be true.. - Disturbances would be the principal mechanism by which the project could adversely impact the Nelchina caribou herd.Additionally,the impoundment behind Watana dam may interfere with caribou migration to and from the <:alving grounds.Utilization of access from the Denali Highway south to Watana dam would he expected -to have adverse impacts on a sub-herd ~alving ground {Pib:::h-er 1982}.Also,if the main herd reacts to -the Watana impoundment by seeking a ~alving area north of the reservoir,~he presence of an a<:~ss road in this area would compound the potential impacts problem.The potential adv-erse eff-ects of the project on caribou relate more~o habitat quality ~han quantity.Project impacts to th-e herd could be negligible to substantial.Thus,although population levels are approa<:hing "optimal",drastic proj-ect impacts could result in this species becoming scarce in the basin. 3.Brown bear (Ursus arctos).This species is considened to be a valuable big game animal and attracts numerous resident and non-resident hunters. The non-consumptive value of brown bears is exemplified by the state- operated McNeil River Sanctuary.Hundreds of people yearly submit applications to obtain an opportunity to observe brown bears in this sanctuary.A lottery system limits the number of observers at the sanctuary to minimize disturbance to the bears. Although not considered threatened or endangered in Alaska,the brown bear is listed as threatened under the Endangered Species Act in the 48 con- terminous states.As such,it can be considered a species of particular national interest and one whose habitat has been significantly r-educed in extent and quality from the national perspective.Accordingly,it is considered scarce on that basis. Project-specific and scientific information on this species is relatively good.Studies funded by the Susitna project have been on-going since 1980.Information on movement patterns,population levels,and location of denning sites is providing a basis for analyzing project impacts. The project would be expected to result in a high degree of direct and indirect disturbance.Although some disturbance impact is unavoidable, the degree to which it can be controlled is large.The type and design of construction camps,mode and route of access,and timing of construction are factors which will dramatically influence the extent of disturbance resulting from this project.Neither direct habitat nor denning sites "... ,,- .~ - """ losses appear to be major project-related impacts (Miller 1982).Prey reduction,however,is expected to result in adverse impacts to brown bear.losses due to prey reductions may be masked by the reductions due to disturbance • Proj~ct-caused losses to a variety of habitats and species will impact the brown bear.Project impacts to the berry-rich shrublands,salmon fishery, areas of early green-up,prey species such as moose and caribou,will all ultimately affect brown bear. According to the ongoing ADF&G studies,HIn comparison with other North Ameri~an brown bear populations,the study area population appeared highly productive and moderately dense.1I (Miller 1982).Even though the population is considered to be moderately dense in the project area, actual numbers are not very high in even the best habitat.A rough estimate of the study areas population is 1 bear/41-62 km 2 {Miller and McAllister 1982). 4.Black bear (Ursus americanus).This speci~s is widespread in Alaska as well as in the 48 conterminous states.Black bear habitat is considered abundant on a national and ecoregion basis. Seasonal availability of foods strongly determine the occurrence of black bears in a particular area.Movement will occur from spring green-up areas,to salmon streams in sununer,and then to berry-producing shrub land in summer/early 'fall.In the project area,brown bear appear to restrict black bears to the forested habitat along the Susitna River and the adjacent shrub1ands to which the forested ar~as serve as escape cover {Miller an&McAllister 1982).Because of this habitat restriction,black bear will be strongly impacted through direct habitat losses due to the project. Black bear habitat value in the inundation area and downstream from the dam sites appears to be relativelY high.In the ADF&G Big Game Studies report (Miller and McAllister 1982)is was noted that,NIn comparison with other North American black bear populations,black bears in the study area appeared to be productive although possibly having an older age of reproductive maturity and higher rate of cub mortality than an intensively studied population on the Kenai Peninsula.No good density estimate was obtained for the study area although a rough estimate of 1 bear/4.1 km 2 was obtained in one relatively open area based on aerial observations of marked and unmarked bears.II Black bear would appear to be highly susceptible to impacts from the project.Indications are that upwards of 90%of the black bear habitat could be lost through inundation.Avoidance of significant losses to this species through project modifications does not appear to be possible.The follOWing is a summary of expected project impacts on the black bear: Nl.lnundation of scarce denning habitats {especially in the upper impoundr.~nt area),2.Habitat elimination through inundation,3. Increased human disturbance and hunting resulting from project con- struction,operation,and improved access,4.Increased predation by brown bears resulting from decreased availability of berry-rich shrublands which. are also adjacent to forested escape habitat,6.Reduction of prey items (downstream salmon,moose calves and,perhaps,caribou),7.Impoundment related climatic changes which alter the availability or abundance of food resources.II (Hiller and McAllister 198Z). Black bear are being examined as a component of the project's environ- mental studies program.Information will continue to be gathered on this species through the project-funded studies and should provide an adequate data base for assessing project impacts.General scientific knowledge of this species is good and thus would facilitate the evaluation of project impacts to biack bear. 5.Gray wolf {Canus ~UPUj).Interest in the wolf is relatively high on a statewide and natlona basis.However,concern for managing wolves to maximize population levels is mixed.Due to its status as an endangered/ threatened 'Species in the conterminous 48 states there is high national interest in protecting this species.from the national perspective,the quantity of wolf habitat has been significantly r~duced,thereby placing it in a scarce status.On ecoregion basis,wolf habitat is abundant and state game management has frequently been directed at reducing wolf populati<>ns in selected ar-eas. Information on wolves in the project area has been accumulated over more than 30 years (Ballard et al.1982b).Studies specific to the Susitna project have been carried out for the last two years.The scientific data base is relatively good and it is anticipated that continued project- related studies will r~ult in sufficient information for mitigation planning. The wolf packs residing in the Susitna study area largely depend upon moose and caribou.A minor proportion of their diet is composed of small mammals (Ballard et al.1982b).Because they are highly dependent upon the availability of moose and caribou,losses to those species due to project impacts would directly impact the wolf populations. The wolf is susceptible to project-related impacts.Impacts to wolves would primarily occur through reductions in prey density,particularly moose.Initially,the project may lead to an increase in wolf numbers due to increased vulnerability of prey which have been displaced from the impoundment areas (Ballard et al.1982b).Disruptions in moose and caribou movements could adversely impact wolves quite distant from the impoundments.indirect adverse impacts could also be anticipated frofil increased access resulting from the project. 6.Dall sheep (Ovis dalli).In the United States,Dall sheep are unique to Alaska.Interest on a national basis is high.The importance of this species as big game and an observation subject also creates high interest from a state and local perspective.On a national and ecoregion basis, Dall sheep habitat has not significantly changed from its historical status and is therefore considered abundant. Consumptive/nonconsurnptive use of Dall sheep is high.Numerous hunters are attracted to the state to sheep hunt.The value of this species for nonconsumptive purposes is exemplified by the state having a prohibition on hunting in areas where sheep can be readily observed. ,.." Three distinct sheep populations,Portage-Tsusena Creeks,Mt.Watana,and Watana Hills,were identified in the upper Susitna basin study area (Ballard et al.1982c).In that the range of these bands correspond to different portions of~he project area,the type and extent of project- related impacts vary.The Portage-Tsusena band would be impacted primarily through disturbance.However,place~ent of borrow pits with associated roads,and project-access roads could result in a significant shift in sheep distribution and a loss of critical winter range (Ballard et aT.1982c)•..Although the project could have a.severe adverse impact on the sheep,the impacts are,if not unavoidable,substantially controllable. Information on the three populations of Da 11 sheep wi 11 continue to be acquired through project-related studies.The studies will be designed to assess potential impacts of the project.Additional scientific information on this species is available,being relatively qualitative in nature.Project-specific data are extremely important with this species due to its fidelity to traditional use areas,which makes assessments of habitat value very difficult in absence of project area-specific information. The Ht.Watana band has not been clearly defined.Apparent use of range adjacent to the Watana reservoir would indicate that project-caused impacts would include disturbance and possible loss of habitat (Ballard et aT.1982c). Impacts tOtM Watana Hills band could be severe due to its proximity to the proposed Watana reservoir.Potential project-caused impacts would be related to disturbance:alter.ed behavior,~creased lambing success,and abandonment of the apparently important Jay~reekrnineral lick (Ballard et al.1982c)... Project impacts to the Mt.Uatana and Portage-Tsusena Creeks populations would be related primarily to disturbance rather than loss of habitat.if long-term,this would result in a decrease in habitat value.Principal concern rests with the Watana Hills band which could lose the use of what is apparently a highly valuable mineral lick at Jay Creek.If the Jay Creek mineral lick proves to be critical to the band and irreplaceable, the value of this habitat would obviously be very high.Studies to ascertain the nature of this sheep population's dependence on the mineral lick are being undertaken as part of the project. 7.Beaver {Castor canadensis).This species plays an important ecological and econo~ic role in Alaska.Trapping beaver continues to be an important component of traditional lifestyles.Beaver trapping is pursued on a recreational basis as well as being an important source of revenue for bush residents.Beaver habitat is neither unique to Alaska nor scarce in the United States or Alaska.They do,however,play an important ecological role.Actions by this species results in habitat modifications \'lhich benefit other wildlife species that are also of high interest (e.g. waterfowl and moose). Beaver are dependent upon both aquatic and riparian habitats.Projects impacts to these habitats would impact beaver distribution and population levels.Although beaver are scarce in the Susitna system above the proposed Devil Canyon dam site,from that point downstream existing population levels gradually increase.At the present time,it has not been clearly established how the project would physically modify the ~usitna River downstream of its confluence with the Talkeetna and Chulitna Rivers.Impact questions which are presently outstanding include: 1.What is the potential for beaver-caused fish passage blockages which may be associated with stabilized flows?, 2.What would be the effects of relatively stable water levels on beaver and their habitats? 3.H~w would the alter~d ice conditions impact beaver and their habitats? 4.What ar~the plant species that beaver are dependent upon and how wou1<1 these plants be effected by the proposed proje<=t?{<iipson et aT.1982). 5.To ~mat extent ar~moose dependent upon beaver for habitat creation? As a c~mponent ~f project fur bearer studies,beaver are bein9 examined. lo~ation of habitations was cornp~eted during the early phase of work. Ouring the se~ond stage of the study potential impacts will be assessed for t~purpose of mitigation planning.Baseline scientifi~inforlilation is relatively ~omprehensive and should lend a high degree of certainty to ililpact predicticns for this species,if post-project water regimes can be adequately identified. Existing conditions in the proposed impoundment areas are not favorable for beaver.Aquatic habitat created by the reservoirs potentially could benefit beaver,however,water level fluctuations could negate this area as habitat.Below Devil Canyon the value of the habitat increases with distance frolil the dam site.Below Talkeetna beaver populations exist in quantities that can sustain a high and continuous harvest (Gipson et ale 1982)•. 8.Pine marten (Martes americana).The pine marten is restricted to coniferous forests and,in the United States,is abundant relative to its histori~al range in Alaska,the Rocky Mountains,and the northern areas of the Midwest and the Northeast.Low population densities are ch aracter i st ic of th is spec i es.Narten are t oca 11 y abundant in the vicinity of the proposed ililpoundment area which corresponds to the forested areas in the upper Susitna valley (Gipson et al.1982).This fur bearer has,historically,been highly important to trappers. Economically,the pine marten is considered the most important furbearer to trappers in the vicinity of the impoundments (Gipson et al.1982). In that pine marten inhabit coniferous and mixed coniferous-deciduous forests,inundations would eliminate much of the habitat of highest value for this species.Sus~ptibility of this species to project-related impacts can thus be considered high.In addition,as this species is associated with older age vegetation,mitigation modification for other species,such as moose,may be in conflict with the pine marten. .- - - As a component of project fur bearer studies,information on this species is being accumulated.Although the present level of detail is not considered high,additional studies are being undertaken. 9.Golden eagle (Aquila chrysaetos).As with the bald eagle,nonconsumptive interest in this species is high.Although protection is also offered to the golden eagle by the Bald Eagle Act of 1940,as amended,this ~egislation is less restrictive for the golden eagle in that their nests may be taken when they interfere with resource development.A permit from the Department of Interior is required in those instances. Susceptibility of the golden eagle to project impacts would be similar to that indicated for the bald eagle.Disturbance type impacts,loss of important habitats,particularly nesting cliffs,and loss of important prey species would all be project-related negative effects which could occur to this species • Habitat to be impacted by the project is not of high value for the golden eagle.Ten active nest sites were identified during the last bw years of studies undertaken for the proposed project (Kessel et al.1982).This concentration of active golden eagle nests is similar to the highest populations noted for Alaska {Kessel et al.1982).However,in a 1974 study C.M.White (1974)did not locate any active gol~en eagle nests in the proposed impoundment areas.This suggests that relating changes in nesting density to project actions could be difficult. TO.Trumpeter swan (CY~l1us buccinator).Interest in this species,on a nonconsumptive basls,is high.Recently close to extinction,the .trumpeter swan is stiTT very rare in the conterminous 48 states.Although restricted to breeding in western Wyoming and Montana the trumpeter swan has recently shown substantial population increases (Robbins et ale 1966). Swan populations in Alaska are associated during nesting and rearing with wetlands and ponds found,primarily,along the major river systems in the southern half of the state.Information on habitat use is concentrated on coastal areas such as the Kenai Peninsula and Copper River (Konkel et ale 1980).Specific habitat to be impacted by the proposed project is not of high value for trumpeter swans. Project-related tracking of trumpeter swans has focused on the impoundment areas.Swans are now considered common in the eastern section of the Susitna study area from the HacLaren River to the Oshetna River.In the last five years the population there has more than doubled (Terrestrial Environmental Specialists,Inc.1982). Trumpeter swans are susceptible to disturbance type impacts during nesting and rearing of cygnets.Lacustrine waters are utilized by this species for nesting and rearing. Aquatic Species Five-year studies are being conducted by the ADF&G,Woodward/Clyde Consultants,and the Arctic Environmental Information and Data Center for the purposes of: (1)providing fish population estimates; (2)identifying valuable aquatic habitats; (3)evaluating project impacts; (4)assessing potential mitigation;and (5)eva{uating the potential for salmon enhancement above the dam site. Water quality,quantity,and other instream flow parameters are to be analyzed to allow an evaluation of project-caused changes vs.fishery resource requirements.Project impacts to salmon habitat will be most apparent in the reach from the Devil Canyon dam site downstream to the confluence of the Susitna,thulitna,and Talkeetna Rivers.Except for a small run of chinook, salmon do not go above the dam site. 1.Chinook salmon (Oncorhynchus tshawytscha).Development of hydroelectric potential in the northwestern United States has resulted in the loss of a significant portion of the salmon spawning habitat.On a national basis, i-nterest is very high in minimizing losses to chinook salmon,and,if possible,expanding existing stocks.State,and local interest is very high in maximizing populations of this highly prized commercial, recreational,and subsistence species. The Susitna River is considered the major contributor of chinook salmon to Cook Inict (AOF&G/Su Hydro 1981).Although chinook salmon of th€Susitna River are not managed at present for commercial harvest,they prOVide important sport and subsistence fisheries.In 1982,approximately 10,000 chinook salmon were taken by sports fishermen with a fishery effort of 28,000 man-days. The primary Susitna River habitats which could be lost between the Devil Canyon dam site and the tri-rivers confluence are the side channels and sloughs.Chinook salmon juveniles rear year-round in the mainstream Susitna River and associated side channels,sloughs,mouths of tributaries and lateral tributaries.Because studies to determine the importance of this reach of the Susitna River to salmonids are still ongoing,project impacts to this species have not been adequately established nor have potential mitigation alternatives been evaluated. 2.Coho salmon (Oncorhynchus kisutch).Hydroelectric development in the Northwest United States has resulted in a significant depletion of coho salmon stocks. The coho salmon is an important commercial resource and a highly prized sport fish in Alaska.The 1981 commercial harvest of cohos for the Upper Cook Inlet was just under 500,000 (ADF&G/Su Hydro 1982).The contribution of the Susitna River to this fishery has been estimated as 50 percent. ,~ .- Coho salmon are also an important sport fish in the Susitna River system. In 1981,sport fisherman harvested over 13,500 coho from the Susitna River system.The commercial harvest of coho in 1982 attributable to Upper Cook Inlet was 777,000 fish. For spawning,cohos predominantly dep~nd upon clear water tributaries with limited use of the side channels and sloughs.The sloughs also provide important rearing habitat (Schmidt and Trihey 1982).Because the side channels and sloughs will probably be affected,cohos are susceptible to project impacts above Talkeetna.The potential of the project to adversely impact important coho salmon habitat below the tri-river confluence has not been clearly established. 3.Sockeye salmon (Oncorhynchus nerka).Past depletion of sockeye salmon stocks in the Pacific Northwest as well as in Alaska has resulted in major interest in this speci~s.Restoration programs have been ongoing in Alaska for several years.Thus there is considerable national,state,and local interest 1n avoiding adv~rse impacts to sockeye,the most commercially important of the Pacifi<:salmon.The 1982 Upper Cook Inlet sockeye commercial ~atch was 3.2 million (ADF&G/Su Hydro).Contribution from the Susitna River to this catch is estimated to be perhaps 1/2 million.Sockeye salmon is also considered an important species to sport and subsistence fishing interests. Spawning flabitat for sockeye salmon above Talkeetna appears to be limited to the sloughs.Although a small proportion of the Susitna sockeye run, those using habitat above Talkeetna will be highly susceptible to project impacts because the sloughs would be prone to project-caused changes {terrestria1 Environmental Specialists,Inc.1982).Below Ta lkeetna,th~ extent of project-related impacts to sockeye salmon has not been adequately established. 4.Chum salmon (Oncorhynchus keta).Commercially,chum salmon are second in value to sockeye salmon in~upper Cook Inlet;the average co"~ercial catch being just over 700,000 during the last ten years (ADF&G/Su Hydro 1982).The commercial harvest of churl1 salmon in Upper Cook Inlet in 1982 was 1.4 million.Sport and subsistence fishing for chum salmon is important,however,it can be considered the salmon species of least value to these interests. Based on ~he 1981 fisheries studies data,chum salmon is the predominant salmon species found in the Susitna reach between Talkeetna and the Devil Canyon dam site (Terrestrial Environmental Specialists,Inc.1982). Predominant use of the sloughs is by spawning chums and as such severe adverse impacts can be predicted to this species if the project results in the elimination of access to the sloughs.Without mitigating flows,the loss of the slough habitats is predicte<.t.Mainstream spawning by chum salmon was noted at ten sites in the Talkeetna to Devil Canyon segment of the Susitna (Terrestrial Environmental Specialists,Inc.1982).The contribution of the mainstream beds to overall chum spawning is not considered to be substantial.Potential project-related impacts downstream of the confluence of the Susitna,Talkeetna,and Chulitna Rivers has not yet been clearly established. Chum salmon habitat historically extended south to the coastal streams of Washington and Oregon.The quality of its habitat in that area has been significantly reduced.Accordin~ly,fro~the national perspective,\/e consider it becoming scarce. 5.Pink sallilOn {Oncorhynchus gorbuscha}.Pink salmon exhibit a two year run cycle.During even years the Susitna River pinks contribute more than any other sal~on species to the commercial catch attributable to the Susitna River.The.cor.lmercial value of this species ,is considered high and the Susitna River is considered the major contributor to the upper Cook Inlet commercial catch.Pink salmon are important to sport and subsistence fishing interests. Information from the 1981 field season provided insight as to habitats of i~portance.Spawning pink salmon were found in the sloughs as well as the tributaries to the Susitna River (Terrestrial Environmental Specialists 1982).Data must be obtained from a peak run of pinks to allow a complete assessment of valuable habitats.Data on odd-year runs may not be indicative of habitats which receive the heaviest use. Pink salmon was historically limited in range to coastal streams of north-west Washington and north.No significant reduction to that habitat has occurred.Accordingly pink salmon habitat is considered abundant on the national and ecoregion basis. 6.Arctic grayling {Thymallus arcticus}.Native arctic grayling are found in Michigan,the headwaters of the Missouri River,and in Alaska {Eddy 1969}. Due to its relatively rare status in the conterminous states,this sport fish is of high national interest.In Alaska,grayling are a popular sport fish.The grayling population within the upper Susitna River basin is rather large,due principally to lack of exploitation.In that it comprises a very healthy population of a popular sport fish,interest on a state and local basis is high. Arctic grayling is the predominant fish species in the Susitna above Devil Canyon.The lower Susitna river smaller populations are found and spawning appears to be restricted to the clear water tributaries (Terrestrial Environmental Specialists,Inc.1982). Based upon data from the 1981 Susitna project field studies the upper Susitna River impoundment areas presentlY supports a population of approximately 10,000 (Terrestrial Environmental Specialists,Inc.1982). Since grayling inhabit Susitna River and tributary reaches which would be inundated,this species will be severely impacted.Downstream from the impoundments,project impacts have not yet been adequately evaluated. 7.Rainbow trout (Salmo gairdneri)fit all the necessary criteria for a mitigation evaluation species and are well suited to represent fish species in the Cook Inlet to Devil Canyon reach.They are considered abundant within their historical range.Habitat to be impacted is of r.~dium value for this species. 8.Surbot {Lota lota}are relatively abundant in the Susitna River year-round and are sensitive to project impacts.They are considered abundant within their historical range.Habitat to be impacted is of medium value for this species. - - I~ 9.Dolly Varden [Sa1ve1inus malma)are an important sport fish and should be considered as an evaluation species as well.They are considered abundant within their historical range.Habitat to be impacted is of medium value for this species. Dau.1982.Wolf. Susitna Hydroelectric the Alaska Power Literature Cited Alaska Department of Fish and Game/Susitna Hydro Aquatic Studies. 1981.Juvenile Anadromous Fish Study on the Lower Susitna River.Phase I Final Draft Report,Subtask 7.10.Susitna Hydroelectric Project.Alaska Power Authority.Anchorage,Alaska. Alaska Departraent of Fish and Garae/Susitna Hydro Aquatic Studies.1982. Stock Separation Feasibility Report,Adult Anadromous Fisheries Proj~ct. Phase I Final Draft Report,Subtask 7.10.Susitna Hydroelectic Project. Alaska Power Authority.Anchorage,Alaska. Ballard,W.B.,C.L.Gardner,J.H.Westlund,and J.R.Dau.1982. Moose-Upstreara.Biy Game Studies Vol.III.Phase I Final Report.Susitna Hydroelectric Project.Alaska Department of Fish and Game for the Alaska Power Authority.Anchorage.Alaska. Ballard,W.B.,C.L.Gardner,J.H.Westlund,and J.R. Biy Gar.le Studies Vol.V.Phase I Final Report. Project.Alaska Department of Fish and Game for Authority.Anchorage,Alaska. Ballard,W.B.,J.H.Westlund,C.L.Gardner,and R.Tobey.1982.Dall Sheep. Big Garae Studies Vol.VIII.Phase I Final Report.Susitna Hydroelectric Project.Alaska Department of Fish and Game for the Alaska Power Authority.Anchorage,Alaska. Eddy,S.1969.How to Know the Freshwater Fishes.2nd Ed.Wm.C.Brown Co.Publishers.Dubuque,Iowa. Gipson,P.S.,S.W.Buskirk,and T.W.Hobgood.1982.Furbearer Studies. Phase I Report,Subtask 7.11.Susitna Hydroelectric Project.Alaska Cooperative Wildlife Research Unit for the Alaska Power Authority. Anchorage,Alaska. Kessel,B.,S.O.MacDonald,D.O.Gibson,B.A.Cooper,and B.A.Anderson.1982. Birds and Non-Game Man~als.Phase I Final Report,Subtask 7.11.Susitna Hydroelectric Project.Univ.of Alaska Museum for the Alaska Power Authority.Anchorage,Alaska. Konkel,G.W.,L.C.Shea,K.E.Bulchis,L.C.Byrne,D.Pengilly,and K.S. Lourie.1980.Terrestrial Habitat Evaluation Criteria Handbook -Alaska (Review Copy).U.S.Fish and Wildlife Service.Anchorage,Alaska. Miller,S.D.and D.C.NcAllister.1982.Black Bear and Brown Bear.Big Game Studies Vol.VI.Phase I Final Report.Susitna Hydroelectric Project. Alaska Departlilent of Fish and Garae for the Alaska Po\{er Authority. Anchorage,Alaska Modafferi,R.D.1982.Moose-DO\'instream.Big Game Studies Vol.II.Phase I Final Report.Susitna Hydroelectric Project.Alaska Department of Fish and Game for the Alaska Power Authority.Anchorage,Alaska. - ,.,,, pitcher,K.W.1982.Caribou.Big Ga~e Studies Vol.IV.Phase I Final Report. Susitna Hydroelectric Project.Alaska Depart~ent of Fish and Game for the Alaska Power Authority.Anchorage,Alaska. Robbins,C.S.,B.Brunn,and H.S.Zim.1966.A Guide to Field Identification Birds of North A~erica.Golden Press.New York,New York. Schmidt,D.and E.W.Trihey.1982.Questions and Answers on Fish.Pages 4-5 in the Susitna Hydro Studies January 1982 Newsletter.Alaska Pm/er Authority.Anchorage,Alaska. Terrestrial Environmental Specialists,Inc.1982.Environ~ental Report. Susitna Hydroelectric Project Feasibility Report Vol.2.Alaska PO\/er Authority.Anchorage,Alaska. White,C.N ••1974.Survey of the Peregrine Falcon and Other Raptors in the Proposed Susitna River Reservoir_Impound~ent Areas.U.S.Fish and Wildlife Service.Unpublished Interi~Report.Anchorage,Alaska. February 3,1983 COMMENTS ON:U S Fish &Wildlife letter of January 24.1983,project area resource categories The Alaska Power Authority concurs with the mitigation goals out- line for species in the project area.These goals were incorporated into the Power Authority's Mitigation Policy November 1981.and revised April 1982.The mitigation plans presented in Exhibit E are designed to achieve these goals. The Power Authority does,however,feel that the process that iden- tifie8 habitat resources in the project area as Resource Category II in- vites comment.The procedures outlined in CFR 46.No.15 of January 23. 1981.seem to indicate that if a resource is abundant on a national scale but scarce in a particular region.then based upon regional scar- city.in that region.it may be identified as R.esource Category II.To work in the other direction.where the resource is abundant on a region- al basis,but not on a national basis does not seem to warrant a finding of resource scarcity. The Notice of Final Policy outlines a procedure for determining Resource Categories.The Alaska Department of Fish and Game,which is the Resource Manager in the project area,does not consider the re- sources in question as being scarce in either the eco-region or the state.Formal comments from the Alaska Department of Fish and Game I~ Comments/USFWS Project Area Resources February I,1983 Page 2 state.Formal comments from 'the Alaska Department of Fish and Game should have been included and commented upon to reflect "consultation and coordination with the state agency responsible for Fish and Wildlife Resources". The technical rationale for designation should also "discuss and contrast the relative scarcity of the fish and wildife resources on a national and eco-region basis". To the best of our knowledge,no area in the eco region (M1310 Alaska Range province)has been identified as an Important Resource Pr_oblem area nor has the project area been identified as such.If it has been so designated,a copy of the designation document from the Director of the Fish and Wildlife Service is requested. Finally,the Power Authority is concerned that the designation of resource values in the Project area as Resource Category II is inconsis- tent in the context of land management activity in Southcentral Alaska. There seems to be little or no basis,when reviewing past and present state and federal resource agency actions in the Project vicinity.to substantiate Resource Category II classification. Comments/USFWS Project Area Resources Februa ry 1,1983 Page 3 While we take strong exception to the designation,it should be re- iterated that Resource Category II goals are consistent with the Authority's goals and mitigation plans for the project.Mitigation planners for the Project would profit by the experience gained in mitigating in Resource Category II habitat and would appreciate being informed of such activity as may be presently on-going in Alaska. JS:gh APPENDIX ElIF CORRESPONDENCE RELATING TO FEASIBILITY ASSESSMENT - ,..,. , - .,.,. APPENDIX 11.F ASSESSMENT OF FEASIBILITY On March 15,1982,the Susitna Feasibility Report was distributed to federal. state,and local agencies for review and comment.It was also made available for general public review.During April and May 1982,all background and support documents were distributed.This appendix contains the list of agencies to whom the report was distributed.A1so <included are agency comments and testimony concerning the Feasibility Report. RECEIPIENTS OF THE SUSITNA HYDROELECTRIC PROJECT FEASIBILITY REPORT Mr.James N.Souby Director Division of Policy Development and Planning Room 450 Court Bu i1di ng Pouch AD Juneau,AK 99811 Mr.Lloyd Pernela Director Division of Energy and Power Development MacKay Building,7th Floor 338 Denali Street Anchorage,AK 99501 Mr.Ron Lehr Director Division of Budget and Management Mai 1 Stop 01 02 Pouch AM Juneau,AK 99811 Mr.Robert J.Cross Administrator Department of Energy Alaska Power Administration P.O.Box 50 Juneau,AK 99802 Mr.John R.Spencer Regional Administrator Region X U.S.Environmental Protection Agency 1200 Sixth Avenue Seattle,WA 98101 Ms.Judy Schwarz u.S.Environmental Protection Agency l\1a i1 Stop 443 Region X EPA 1200 South 6th Avenue Seattle,WA ~8101 Colonel Lee Nunn District Engineer Alaska District u.s.Army Corps of Engineers P.O.Box 7002 Anchorage,AK 99510 Mr.Keith Schreiner Regional Director,Region 7 U.S.Fish and Wildlife Service 1011 E.Tudor Road Anchorage,AK 99503 Mr.Robert Bowker Field Supervisor u.S.Fish and Wildlife Service Western Alaska Ecological Service 733 West 4th Avenue,Suite 101 Anchorage,AK 99501 Mr.John Cook Acting Regional Director Alaska Region National Park Service. 540 West Fifth Avenue Anchorage,AK 99501 l\1r.Larry Wright National Park Service 1011 E.Tudor Road,Suite 297 Anchorage,AK 99503 Mr.John Rego Bureau of Land Management Anchorage District Office 4700 East 72nd Avenue Anchorage.AK 99507 Mr.Robert McVey Director Alaska Region National Marine Fisheries Service NOAA P.O.Box 1668 Juneau,AK 99802 Mr.Ron Morris Director Anchorage Field Office National Marine Fisheries Service 701 C Street Box 43 Anchorage,AK 99513 Mr.Max Brewer Office of the Director Special Assistant for Alaska U.S.Geological Survey 218 E Street Anchorage,AK 99501 Mr.Ronald O.Skoog Commissioner State of Alaska Department of Fi sh and Game Subport Building Juneau,AK 99811 Mr.Thomas Trent State of Alaska Department of Fish and Game 2207 Spenard Road Anchorage,AK 99502 Mr.John Katz Alaska Department of Natural Resources Pouch M Juneau,AK 99811 Mr.Alan Carson Alaska Department of Natural Resources Pouch 7-005 Anchorage,AK 99510 Mr.Ty Dilliplane State Historic Preservation Officer Alaska Department of Natural Resources Division of Parks 619 Warehouse Avenue,Suite 210 Anchorage,AK 99501 Ms.Kathy McConkey Copper River Native Association Drawer H Copper Center,AK 99573 Mr.Ernst W.Mueller Commissioner Alaska Department of Environmental Conservati.on Pouch 0 Juneau,AK 99811 Mr.Bob Martin Alaska Department of Environmental Conservation 437 E Street,2nd Floor,Suite 200 Anchorage,AK 99501 Ms.Lee McAnerney Department of Cornmunity and Regional Affairs Pouch B Juneau,AK 99811 Mr.David Haas State-Federal Assistance Coordinator State of Alaska Office of the Governor Division of Policy Development and Planning Pouch AW Juneau,AK 99811 Ms.Wendy Wolf Office of Coastal Management Division of Policy Development and Planning Pouch AP Juneau,AK 99811 Mr.Lee Wyatt Planning Director Matanuska-Susitna Borough Box B Palmer,AK 99645 Mr.Roy Huhndorf President Cook Inlet Region,Incorporated P.O.Drawer 4N Anchorage,AK 99509 Mr.Max Dolchak Executive Director Cook Inlet Native Association 670 Firewood Lake Anchorage,AK 99502 ,..., Mr.Herb Smelcer President General Manager AHTNA Corporation Drawer G Copper Center,AK 99573 Mr.Michael Meehan Director Planning Department Municipality of Anchorage Pouch 6-650 Anchorage,AK 99502 Director of Planning Fairbanks North Star Borough 520 5th Avenue P.O.Box 1267 Fairbanks,AK 99811 April 16,1982 DEPAR!}lENT OF NATURAL RESOURCES'S TESTIMONY TO THE ALASKA PO~ER AUTHORITY BOARD Of DIRECTORS I appreciate the opportunity to provide comments to.the Power Authority Board of Directors on the Susicna Hydroelect::ic project:.I r-egret that, because of other commitments in Juneau,I am unable to personally deliver these cotmUencs. At the invitation of the Alaska Pover Authority.the Department of Natural Resources has been Yorking informally with the Authority over the last tvo years to help fonaulate and carry ou::studies designed to ansve~the questions which ultimately vill de~errnine whether the Susicna Dam proposals are feasible.the purpose of this testimony ~oday is tvofold:First,to identify Susitna Hydroelectric issues that are vi thin the sphere of DNR's authority;and second.to make recommenda- tions c.o the Board of Direc~ors on the continuation of project develop- ment,as requested in che January 26 letter from Mr.Conway. SUSITNA HYDROELECTRIC RELATED ISSUES ~I!HIN THE PURVI~~OF THE DEPARTMENT OF NATUPAL RESOURCES The Department of Natural Resourees ~ill be required to make decisions on.t~O major facets of the Susitna Hydroelectric Project.These are:..,.:.~-".~. 1.DNR responsibilities for l:ater appropriac.ion·(and .possibly instream flov reservations)fro~the Susitna River.. 2.Rights-of-~ay pe~its for access inco the dam sites and transmission line routes.Other land use permits for access to construction sites. gravel for construction.and other land use related needs as they oecur on state oYned lands. The role of the Department of Natural Resources in ~at.er rightS appro- priation vill be an adjudica~ory one.According to Alaska Statute ~6.15.0aO (b),the impacts of vater appropriation on the public interest shall be considered during adjudication.Areas of public interest are defined in the Statute as follous: 1.The benefit to the applicant result.ing froe the proposed appropriat.ion. 2.The effect of the economic activity resulting from the proposed appropriatio:l. 3.The effect on fish and game r~sources and on public recreational opportunities. 4.The effect on public health. - .- - ~.The effect of loss of alternate uses of water that might be made vithin reasonable time If not precluded or hindered by the propos~~appropriation. 6.Ham co other perSO:1S resulting frore the proposed appropr:iat10n. 7.The intent and ability of the applicant to complete the appro- priation. 8.The effect upon access eo navigable ~aters. Tne DUR ~ill be looking to the Feasibility Studydaca and information to describe the relationship between various streamflo~levels and ho~they yii!impact fisheries.and aquatic habitat downstream.Thus.from this Depart.AIlene's perspective.inscream f10\1 studies and the ·relationship of various flo~ievels to aquatic habitats and fisheries .resources are vital.The studies administ.ered by the APA will be the fundamental source of dat.a and inforGation used by DNR to make the public interest findings described above.'-!eare eager to'reviey and comment upon the present and future plans for instream flev studies.To'date.\;.e have not been provided an ¢pportunity to reviey or comment upon the instream flow study approach. The access to the dam sites and the .policy surrounding the extent of access after construction ~ill lead t¢one of the most ~ignificant im?acts of the project.The Poyer Authority has seated that the perm1t. for use of a "pioneer road"is needed in 1982 (before a F.E.R.C.permit is issued)if the power is to be on line ele,,·.en years later •One signifi- cane issue is the possibilit)'of the 'Construction of a road to'the proposed ciat:::sites ana a subsequent decision b)·the'st31:e'not ·to c6nstruc't the ca:!!s.It vould appear to be in the best interest of the Pover . Authorit~·.the land managins agencies.and the public to identify other alternatives ~hich ~ill allo~the necessary access to the proposed dam sites in a manner ",hich prevents irreversible impacts.In order to prevent this issue from beins a potential delay in progress.ye ~ecomm~nd that the A1'.A.take the lead in convening a multi-agenc)'.multi-discip1.inary effort to accomplish the goal stated above. The second issue is the long term land use implications of access to the proposed da~sites.The provision of access to the dam site~should not unYittingly determine the t)'pes and extent of land use impact on the surrounding lands in the upper Susitna Valley.Carefully determined access route decisions could result in a multiple purpose route vhich could facilitate and enhance other uses of the surrounding lands.In order co accomplish this.tn..:Cii!r.Oiccess route ciecis~on should be made in conjunction vith su~rounJing land cuncrs,land manage~s,and the general public.As on the other-issue above,the DNR is villing to participate cooperac.h·ely vith the Alaska Pover Authority,other agencies, and the public to resolve this ~att~=so that it does no:beco~e a potential delayin£factor for the proposed project or a future manage- ment problem for land o~:ne:."S .:md ma:lagers. sml"4.ARY AND RECO~·l?'1ENDATlONS In s~~ary.~he Department of ~atural Resources has three recommenda- tions: 1.The Department supports continued studies in the socio-economic, technical,and environmental areas.The preliminary uork accomplished so far indicates that the project is technically feasible.Further ~ork is needed to establish the information and data for uater appropriation and fishery mitigation.Additionally,ue recommend further ~ork on the timing,route and conditions of access to the proposed dam sites. 2.With respect to the ques~ion of ~hether it is desirable to submit an application to the f.E.R.C.on September 3D,1982,ue offer the follo~ing co~ents.The APA Board of Directors and the staff should carefully ueigh the advantages and disadvantages of sub~itting the formal application on September 30,1982.If that course of action ~ould result in the APA acquiring a F.E.R.C. permit to construct in the most timely and economical ~ay,tben that course of action makes sense.HOl.:ever,if on the other hand, a formal application would result in delays,increased pot:eotials for litigation,and a hardening of acversarial roles bet~een the APA,other agencies,and other int~rested parti~,~hen the possibility of these delays should be considered.~e believe that the APA Board and the Stafi are io the best posicion to evaluace pros and cons and to determine uhether a F.E.R.C.application on September 3D,1982,is desirable or not.Froe our more narrov agency standpoint,DNR is not oppoJed to a F.E.R.C.application so Ions as our agency concerns and reJponsibilities can be fully ana openly det.er.nined through the traditional intervenor process. 3.We co~pliment the APA Board of Directors and staff for encour- aging inter-agency interdisciplinary approach to identify ~ays to improve ehe coordination and ultimatelY the results of the feasibility studies.We believe that strengthening this approach vill facilitate a more cooperative and constructive role for those agencies uhich have responsibilities that require them to take action on the Susitna Hydroelectric Project.Specifically,we recommend strength- ening and enhancing the role of a group similar to the Susitna Hydroelectric Steering Committee which has been providing informal agency comments to the APA on this project for the last tuo years. """ 1.Inadequacies of population estimates of:1)moose and other large animals in the downstream Susitna below Devil Canyon;2)caribou subherds in Talkeetna River,Chulitna Hills,and Upper Susitna-Nenana drainages;3)wolves in the Keg Creek,Porta~e Creek,Stephan lake,and upper Talkeetna River;4)wolverine throughout the study area;5)black and brown bear with the entire study areas;6)marine mammals such as Beluga Whales in the lower downstream estuarine area;7)even year numbers of pink salmon. 2.Major data gaps exist concerning the use of specific types of habitat of certain species during various seasons.Among these are:1)use of downstream vegetative by moose and bear;2)use of the main stream reservoir area of vegetation by moose during severe winters;.3)use of the impoundment area in spring by black and brown bears;4)home ranges of black bears;5}use of sloughs in the lower Susitna by fur bearers and water fOW1;(§j use of the mainstream Susitna and other sloughs below Talkeetna by salmon and other fish species;and 7)significance of the mainstream/clea~ "water confluence areas for chum and coho salmon spawning and distribution of juvenile salmon all resident fish throughout the main streamSusitna,especially in winter months. 3.Much additional study is needed to address complex issue of interrelationships between species wfthin th study area.Specific information needs are:1)seasonal predation levels upon moose and caribou by black and brown bear and wolves;2)importance of moose and caribou carion to species of wolverine,red fox,and other 1 small mammal;3)use of salmon population by black and brown bear; and 4)potential conflicts between black bear and brown bear populations caused by displacement during project construction. 4.Report fails to project any estimates of potential numbers of species that would be actually gained or lost as a result of project construction.Specifically:1)loses of moose through starvation resulting from displacement;2)moose losses through increased predation by wolves and bear~on displaced population; 3)loss of moose,caribou,bear,wolf,~ther other species through \O'i~ road strikes;4)hof moose,caribou,bear,etc.through attempts to cross the reservoirs;5)effects of increased predation upon caribou by wolves as moose populations decline;6)losses to black and brown bear through unavailability of Prairie Creek and lower Sus;tna Salmon populations;7)10;Ses of brown beans through interspecies conflict caused by human disturbances,displacements, and reduces food sources;and 8)losses of black bears through intraspecies conflict with brown bears. 5.Report deficient in fisheries.Specifically:1)loss of potential enhancement possibilities for salmon upstream of Devil Canyon;2) losses or gains associated with potential alteration of habitat below Devil Canyon to Cook Inlet;3)losses to anadromous and resident fish downstream from Devil Canyon during the filling of the reservoirs;4)losses or gains associated with artificial manipulation of fish habitat recommended as mitigation for salmon 2 i--- - - ,.... losses;5)losses associated with increased fishing,both legal and illegal,due to increased access. 6.Although report addresses all species and potential impacts,it fails completely in almost all cases to identify specific losses on any real means to offset even the very generally identified impacts to fish and wildlife. Examples:1)Upper basin moose,.~)feport recommends only compensation by prescribed burning and also states method is experimental and needs more study;2)black bear -report recommends 1iteratu~e review to identify management techniques or compensation with other species;3)brown bear -no mitigation recommended other than aiding other local species; 4)woJf -unless moose mitigation works no other recommendation made;5)wolverine -no recommendation other than aid to other species;6)salmon -habitat loss through flow reduction will be mitigated by modifications of the existing stream or by adding gravel build spawning areas, artificial spawning channels and hatcheries are mentioned but no discussion of the hig~~Xperimental nature of these types of projects in Arctic environments;at and 7)salmon -no discussion of potential impact of mixing hatchery stocks with wild stocks;8)salmon -temperature problems downstream of Devil Canyon will be mitigated via multi-intake flow system-although no evidence i s presented to substantiate this claim;-9)resident fish -no information is presented to support 3 claim that a viable recreation fishery could be maintained in reservoi rs. 7.Current demand projections are not weighted to consider the last ~--several years when price -induced conservation has dramatically-reduced the demand for electricity. 8.Acres·report did not address salmon enhancement possibilities in upper Susitna basin. 9.Acres'downplayeddevastating impacts of the project on the ~ ~elchina caribou herd du~to increased hunting pressures and interruption of traditional migrating ground. 10.Moose habitat along the River would be greatly diminished by the decrease in the willow growth. ..s11.The Watana studies state that in 100 yea~the reservoir will fill some 5%of its)'total volume with sediment •••All estimates for sediment load are based on the river carryin~~t 10%or 5%,or,.. even 1%sediment load by volume,but .04%as the sediment load ••• What this estimate says to me is that research ;s long on watered , down data and short on practical judgement. 12.The way it is designed now the Watanareservoir would become silted in 25 to 35 years.This is at a 5%sediment bearing rate -for below the 30%which is possible for glacial rivers to run at. 4 should have figured out how salmon can d.~\1\:' the sloughs can be prevented from Aup,-- ..... ..... 13.I question the amount of mixing Acres'suggests sediment will be undergoing in the reservoir,and I question the entrapment rate or the rate at which the silt falls out of the water and settles in the reservoir~Despite abundant research which would indicate entrapment rates sUbstantially high,Acres American advances 70%as the lower end of their entrapment studies,or entrapment estimates. It disturbs me that probably the simplest measure of sediment load, the ratio of sediment to water,in never plainly stated. 14.Scanning Acres American's research •••I question thp.lakes that they draw for comparison.There are substantial differences between natural lakes in ~outhern British Columbia~nd the Watana Reservoir.The one in British Columbia is about a ninth the size of theWatana reservoir. 15.Our particular concern is the destruction of salmon spawning area in the Susitna sloughs •••before we go or with this project I believe that they (Acres) -t'o-c,..') spawn successfully~~how "how the fish will have clear water,and the sufficient amount of water with the dams being raised and lowered. 16.I have real problems with this base case plan,in that it is predicated entirely upon the development of the Beluga coal fields and to a world class exporting coa~complex within the next ten years •••I feel that the base case plan,with all of its critical assumptions regarding massive coal production within ten years from 5 what is currently only a potential prospect,and further restricting this potential to the whims of the foreign coal market' is a fictitious economic measuring stick. 17.What bothers me most about the proposed Susitna project is the lack of a complete picture of information ...'The Acres I report seriously down-played the uncertainties and fail~d to show all impacts and methods of mitigations.The uncertainties include whether the project is truly,economically feasible.A cost overrun of 20% makes the project uneconomical. 18.I have found that we can~ot adequately evaluated the potential environmental impacts of the proposed Susitna Dam ...with the first year of extensive fishery and wildlife studies now complete,I feel that it is impassible to determine whether the project is environmentally sound.Similarly,I feel it is also impossible to compare the environmental impacts of alternatives because of lack of information. 19....if we build one dam,the Watana dam,and then the power needs do not live up to what we think they are going to be,we can just build one dam.However,it does not actually come out and say it in the Acres l Report,but their figures show that 70%of the cost of this project is in the first dam.However,that first dam is only projecting 50%of the power output and gigawatts,which is the p actual power that we are paying for per kilowatt.If we did build one dam,with the cost estimates in the project of the 20%,17 to 6 - ..- 20%overrun,making it unfeasible economically,than building one dam -the Acres'Report says that in buildin~one dam will not be economically feasible,we have to build both dams to make it economically feasible. 20 ...1 would like to address the proposed road access to the dam site...I feel that it would be a lot more economically viable to use the old cat trail that goes across the top of the ledge over to Portage Creek and build one bridge across Portage Creek and then go on up to where the dam sites are •••If they go ahead and use the road access that they are talking about at this time and put the bridge across the~sitna down below Indian River next to the---rai~road trestle,that is going to mean enlarging the staging area at Gold Creek and there is going to be a lot of activity going on in th~t area;in a real remote situation. 21.The Acres'report also states that this completed project would result in the shutting dawn of all other generation facilities in the Railbelt •••In case of a failure of any sort on the facility, power generation or transmission wquld cease or seriously be impaired.It seems more feasible to have numerous smaller hydro, natural gas,wind,solar,and geothermal-thermal facilities to distribute the stress providing the electrical power. 22.Why;s the preferred or chosen access route a road from the Park Highway?:which would,according to the Vice President of Acres ...,)~e"American,be double wide and paved,wbere the overwhelming majority 7 - of th=~~ple in this area favored and all rail route to the site of th~pr~Dosed project. 23.The proj~itself would add a serious blow to ridding the state of its boom/~ust economy_A recent report by the Army Corps of Engineer~:entitled 'IRainbow or Opportunities"states that 70%of the labor"-'force for this project would be made up of skilled trades c-- from out$f~~e Alaska. 8 .- - RESOURCE AGENCY'S COMMENTS 1.There is been a failure to quantify the habitat types present,a failure to anticipate impacts,and to identify the required mitioation •••Some of the followinq deficiencies have been noted: .~~- 1)~rrestrial studies have focused on the impoundments and their immediate vicinities~neglecting in large part the downstream areas,transmission and access corridors of secondary or indirect .., 2.Access is the topic being discussed.We also have some concerns of the environmental impacts.Those routes are:1)the one south of the Susitna River between Devil's Canyon and l-latana;2)the corridor paralleling the Indian River;and 3)the route proposed so~th of the Denali Highway.The impact here (Denali)is somewhat mitigated by the western route as opposed t the route via Butte 9 3. Lake.It is still unclear as to the relative magnitude of the impact on caribou posed by the western route south of the Denali Highway.While we are concerned as to the impact on that caribou herd,we feel that the environmental trade off in question is o~e of the impacts -the caribou herd versus the impacts of more projective habitats in the area of Indian River or the Fog Lakes area.From an environmental standpoin~,the route southerly from the Denali seems preferable from the aspects of minimizing disturbance of projective habitat.The route form the Denali, however,poses a secondary impact;that of human access to the project area after construction. General comment that both the Acres'and Battelle studies were lI ultra conservative.II I would like to point out just a few of the numerous items that led me to the conclusion previously mentioned. For instance,the coal alternative anticipates an operating coal mine at Beluga supplying a major export market.This mayor may not be a reasonable assumption;however,the manner in which it is applied in the study certainly places the coal alternative in the best possible situation.In addition,the coal alternative did not anticipate worst case environmental restrictions over and above those now on the books.The worst may be yet to come relative to burning coal and the added cost ..•One other item,as I understand the environmental assessment,all the moose at Watana over a two and a half year period are considered dea-d moose.I believe this assumption to be an unduly harsh evaluation and not realistic. 10 - .- 4.Downstre:am water quality changes are certainly going to exist as a result oT the project ...•what we do not know at this point is what "do these ~harges mean or what they imply in terms of downstream biologica]effects or downstream morphological effects on the actual stweam bed itself...•The second group of concerns .••are downstream flow volumes and water levels •.••Apparently the project envisions as much as a foot and a half of lower water level in the summer ••••'Hbw does this effect side channel situation,the habitat--areas,what about sediment transport?How does it effect the recreatiol'1lal use of certain reaches of the downstream area,what c.lc....s.s about river travel,aesthetics,etc ••••Another Aof concerns would be construction camp impa.cts ...•Where are you going to discharge sewage,how are you going to treat sewage,where are you going to get your water supply,what about power?••Another concern, auestion,I have relates to what are going to be the recreational impacts of a town of say 4,000 or so located in the wilderness?•• They are going to want to hunt,to fish ••••To what degree i~·that going to be controlled or managed?What are those impacts;how serious ar they?.•The final class of specific questions that I raise relate to the access issue on transportation issue to the dam sites themselves.First,I am still exploring my view of the feasibility work in reasoning behind the model question in why we are going road transportation as opposed to rail.Are there some gains to be had in going with the rail transportation or a rail access situation?••I am not saying rail is the best way to go,I am just saying that it seems like we eliminated that possibility po~sibly out of hand • 11 SRA Box 1628 Anchorage Alaska 99507 April 16,1982 Charles Conway Jr.,Chairman A~aska Power Authority Beard 334 West 5th Avenue Anchorage,Alaska 99501 Dear Mr.Conway: The thirty day review period allowed for public comment is way too short of time to review and formulate comments on such a volume data being presented by ACRES on the Susitna Hydroelectric Project Feasibility Report.A minimum of 60-90 days should have been allowed.Because of this short tirne element, only the access route to the Dam site is being addressed since this is probably the most controversial environmental issue.The Dam projects themselves have only minor en~ironmental impact on both the biological and social environment. In reviewing ACRES "Selection of Access Plan"found in Volume 1 Engineering and Economic Aspects,Section 9-19 Final Draft,and its relation to the Environmental Assessment Report,Feasibility Report Volume 2 Environmental Report Sections 1-4 and 5-"Final Draft,there is not sufficient data available to verify or uphold their reasons for selecting one route-over another. A good example of this is the Upper Susitna-Nenana subherd which is also called by anothe!"name elsewhere 1n the report.The Denali route (Plans 6 and 11)was disregarded because of the environmental impact the road would have on this subhe!"d.Yet in the main environmental assessment on car~bou, only two sentences where dedicated to this herd.How can anyone make a sound judgement based on this absolute minimum informat~on.Any comments referred to this sub herd in the selection of the access plan can only be accepted as unconfirmed assumptions.One can also assume from the lack of data presented in the main environmental assessment that someone is blowing out of proportion the impact the Denali route will have on the subherd. The following are specific comments to the various statements made concerning the recommended selection of the access route. Page 11-4 11.4(a)Corridor 1:In listing the major environmental constraints the Hurricane-Cold Creek furbeare!"habitat was left out. This was a major concern in the evaluation portion of selecting the recommended rou te. Page 1'-13 ".8 (e){i)Effects on Big Game:,. (1)1st Sentence:What is the potential effec~the selection of an access plan will have on the Nelchina Caribo~herd -specifically the subpopulation?The main environmental assessment only had t~o sentences on this particular herd so the importance cannot be too great. f.we,;)/:, (2)'3rd Sentenpe:It states impacts on hunting for moose and bear can be greatly ~essened by selecting a route other t~an the Denali High .....ay. 1stParagrap.h -What about the angling preasure upon the resident fisheries oC Miami Lake and the streams of Indian River,Portage Creek and other streams Ceeding into Susitna River along the Parks Highway ~ute?In actuality this shouldn't be consern for any route since through good Cishery management the lakes and streams ,can be stocked thus improving the fishing'potential. No matter what route is selected the hunting '..ill impact any game. Also under major environmental constra.ints identified with each corridor,moose is not mentioned in Corridor 3 (Denali route)yet it is mentioned in Corridor 1.Bear is not mentioned in any of the routes. ,"- .-I cD Page (1) 11-13 11.8 (e)(ii)Effects on Fisheries: (2)2nd Paragraph -The impacts on the salmon fishery in Indian River, Portage Creek and the Susitna River below Protage Creek could be avoided completly using the Denali access route.Instead the solution for reducing the impact was to avoid road access paralleling the Indian River.But on all road location maps,the road is shown paralleling the river and crossing the Susitna River at Gold Creek.Even if the road doesn't parallel the River,it will increase the fishing presure both up and dowqstream Cor several miles where the road will cross the River.In this case, the distance could be greater because of the excellent trail prOVided by the railroad bed which'parallels Indian River. ".8 (e)(-iii)Effects on Furbearers:~Page 11-14 (1)}~t type oC potential negative impact will the access road crossing have on the furbearers?It is questianalble that the road traffi~will effect the fox dening areas that are ~ocated one mile from it.Through proper hunting and trapping ~egulations the furbear impact can be reduced to a nomimal impact for any of the routes selected.As to loss of habitat,the Denali route ~ill have the less disturbance according to 11.5 (d)(iv)which states "The terrain is relatively flat with few ';"etlands involved.I' Effects on Wilderness Setting:11.B·(e)(v) (2)Last sentance -This is a misleading statement."By indirectly indicating the Gold Creek -Devil Canyon has the least impact on furbearersby selecting this access,it leads the.reader to believe this is the prefered route over Denali Highway.There is still the wetlands between Parks Highway and Gold Creek which are important to fUrbearers that has to be addressed further.·GPage 1l-1~ ,~ This is a mute question.·There is no .~y to maintain the status quo to the maximum extent possiable due to the type or project being developed and landownership envoled.By creating a 2 116RaS<----reservoi~of this magnitude will cause an outc~y of ~he gene~al public to develop the recreation potenti~l of the area.This will be compounded by the private landowners seeking to tap this desire for economical gains.The access will also allo~the private landowne~s to ex?loit the land ~hich is now in a wilderness state. There are three ways to retain the impact into the area.The first, is cancel the whole project.The second is by railroad access only,both during and after construction.This still would allow the private landowners to exploit their land.It is queationable if the majority of the public would buy this type of access.The thLrd way would be a road in from Denali Highway.The route is the furthest away from the major population 'center of Alaska.This ~ould have the tendancy to reduce the recreational t~affic.There would be no road access to the south side of the Susitna River which would retain it in a wilderness 'catagory unless the private landowners wants to build a bridge accross the River at their expense. A short spur road from Wantana Dam site down stream to the head waters of the Devil Canyon Dam Reservoir ~ould allow boating recreationist to use the reservoir.This would allow for restricting road traffic between the two dams to only project maintance work.This would preserve the semi-wilderness characteristics of the area surounding the Devil Canyon Dam Site. 11 -19 11.a (h)Transmission: 2nd Paragraph.It states that if the Denali access route is selected,one of the reason for not constructing the transmission line in the same corridor was the adverse visual impact.Yet no mention was made to the visual impact it would have on the,Parks Highway route which would be even greater due to the development in the Gold Creek -Indian River area,the Alaska Railroad and the access road itself. 2nd Paragraph -When ever a new access is open up into an area it creats an impact upon the natural resources if left unchecked. This is where proper resources and land use management planning comes into being.Prior to creating a new road,in fact for the whole project,a management plan should be developed to offset or reduce the overall enVironmental impacts to an acceptable levels. The plan should include hunting.fishing,and trapping regulations, a desirable animal-habitat ratio,ATV closures to protect·the fragil vegetation or animal disturbance,determine which archaeological sites are valuable to preserve and excuvate,what recreational and other development is needed to serve the public, land use allocation,etc. ""6)Page (l) (9 Page :1) 11-19 11.9 Evaluation of Access Plans: .. 2nd Pa=-~.g::-:aph -According to 11.5 (d)(iv)the Denali route ;.;ill disturt::::=e lease amount of ·...etland habi ta t so this can not be a signifL~a=t concern when comparing one route ;.;ith another.It is questi~a~le if the fox denning complex (18 dens)would be effected by a rcad one mile away. J Page (1) 11-20 ~~..,11.9 (a )(iii)Biological: -. (2)Just h~~portrant is the calving and summer range for the northwe~t.e.rn subgroup of the Nelchina caribou herd?As 'previous stated on.!.y two sentances were devoted to this parti.cular herd in the maLo environmental assessment.Even the map which outlined the caribolJ calving areas didn I t show the loctaion of this subherd calving a~~a.The location was first mentioned under 11.4 Corridor Selection and Evaluation where it stated it was near Butte Lake. Accordit:lg to plate 11.2,the calving ground ·....ould be 8-12 miles from the r-oad so its queationable if .either the road construction or'traf'!'ic:would have any effect on,the cows during the calving period. Through proper management,the construction period of the road near the calving area could be restricted until after the calving period takes place.This could also apply to the migration period.After construction,road traffie could be reduced to the minimum for the same periods. (3)3rd Paragraph -The consern on opening up the area to more ATV use can be.stopped through land use management regulations or game regulations.The area can be closed to ATV use.The USDA-Forest Service !'las done this quite efficently on the Kenai Peninsula and the Copper River Delta (which encompess approx.300,000 acres). T!'le ADF&G has also carried this out through their walk in hunt areas through out'the State.Therefore,this is not a valid consern. (4)4th Paragraph -Who are the particular resource agencies that are apprehesnsive about 'the success of any mitigation plans for the Denali route?Are they a one resource agency or a multiple use agency who deals with these problems on a everday ~asis? C9 Page 11-24 11 .9 (c )(iii): (1)lst·Paragraph -The same discussion as stated in comment 8 pertains to this discussion on the caribou herd. 10J Page 11-26 &27 11.10 (b)Social vs Biological Considerations: /----(1)1st Paragraph -As stated in previous discussions,proper and timely development of land use and resource management plans can resol'/e or reduce toa minimum the conflicts discussed for the Denali access route. ~>c These same conflicts mentioned ~ith the exception of the caribou ~ apply to the ?arks Hig~~~y.?~obably more so after reading the varius environmental assessments on wildlif~and fisheries for the area.Therefore,the only conflict is to the caribou herd.As stated,through ATV closures and roa~traffic restrictions this conflict can be resolved.A few ATV users will be displaced,but there are other areas to the east of the Susitna River they can use instead. 2nd Paragraph -Any routes selected could result in unacceptable delays in licence approval especially if Federal land or wetlands are envolved.Since the project is a major environmental issue,a Environmental Impact Statement will have to be filed.This alone can take up to two years or more to p~epare and be approved. ,r-C.9 Page (1) '1-28 11,.11 (d): 1st Para~~rr -This is not a valid statement since through proper and timely la"nd use management planning the ATV traffic can be controled t.h.rClugh ATV closures. (2) (3) 2nd Paragrapn -On what bases is the statement made that biological perspective,the Parks Highway is a prefered to a Denali Highway .access.If land use management planning is done before hand,the overall biological perspective would be equal. 3rd Paragraph -Even though the additional 52 miles of haul distance is invoLved,the cost of constructing and maintaining the talked.about pi.cmeer road plus ware and tear on the vehicles will far out weigh.t:he additional cost envolved to haul the supplies an extra 52 miles over an all weather road.In order to haul the type and tonage of equipment needed for the dam project,the temporary haul road will require extensive construction. Environmentally,construction of two roads in the same area is not wise •.It will double the disturbance to the environment and the finally abandoned road -",ill attract ATV use on an unmaintained road which eventally will cause erosion problems. (4)5th Paragraph -Allowing the access route and transmission line to use the same corridor would cause a visual impact.Since the Denali route for the transmission line was dropped because of high cost and visual impact,the line must go west paralleling the proposed Parks Highway route.Thus from a visual stand point,the-Denali access route has the advantage over the other routes.This was never brought out in the write up. (5)7th Paragraph -Instead of creating a major railroad head at Gold Creek,construct the railhead six miles up stream from Gold Creek on the large alluvial flat located there.This would reduce the social impact on the commumity except for the additional train traffic during the construction and several switchmen station there. (6)9th Paragraph -This is not a valid assumption.Plan 6 would net increase the social cbange at Gold Creek other than the short period of'constructing the railroad and the increase train t:"'affic during the Devil Canyon Dam construction period. ..... - (7)10th Paragra.~h ,..This assu.:nption applies to the other routes. Because of the major issues involved conbined ;..rith Federal land,an Snvironmental Impact Statement will be required • (8)11th Paragraph -Cant~ell will be the only cOIJ".D1uni ty effec ted and they are inravor of the socioeconomic benefits :he construction will bring them.Therefore,the mitigations would be nominal incomparison to Talkeetna and Trapp~r Creek. 12th Paragraph -This is invalid statement •.As stated before,ATV closures and hunting and trapping regUlations can control this activity.In the long run,an effective management plan using ATV closures would reduce the harassment of the animals 1n the area, preserve the delicate,shallow soil and vegetation from being torn up by the present unrestricted ATV use,and '..lOuld allow a fair game hunt of the caribou by walk in hunters only. This has been a vary effective tool on the Copper River Delta ATV closure that was once op.en to unrestricted ATV traffic.The Denali !"oute and the Copper River Delta area are similar in nature.This has also been effective in the ADF&G walk in hunt areas. (10) e page (1) 13th Paragraph -The foregoing considerations as presented by ACRES are not valid for eliminating the Denali route based upon the comments under this section.For some reason or another,someone is arfraid of having a good land use andresourse management plan developed and approved for the area and car~ying it out. 11-30 &31 11•12 Recommended·Access Plan: 2 &3rd.Paragraph -No con~truction of any pioneer road should be built until an ~EaC license is aproved.If one is put in from Gold Creek amd the license denied,the Native corp.oratins wil~press legislat~rs to retain the road for the development of th~ir lands at no cost to them.This means public funds would be used to benefit a private corporation. (2)4th Paragraph a.What type of special construction ~echniques will be utilized to minimize the impact eo furbearers and fisheries?This is a" ~broad statement and has no real meaning.It should be more specific as to the type.Is this additional cost figured :nto the overall cost to the project? - b.Under".8 (e)(H)Effects of Fisheries it was recommended the road access avoid paralleling Indian River.This recommendation ~s ignored.Why? (3)5th Paragraph a.The first sentance percludes to the fact that the highly recreation value of'the project will be denied to the public. If this is the case them,a 'Whole new evaluation o.f the varius road access routes be made conserning the overall recreation· potential vsnot allowing recreation potential be developed. 6 b.The second sentance creats a two face situat~on consern~ng ATV '.lse and hunting.It can be assumed 'that ATV and huntir.g restrictions can ~e imposed and controled for ~he Parks Highway route but not on·the Denali route. (q)6th Paragraph -w~at about the impact the road will have on Indian River Remote Parcel and Gold Creek?Mitigation measures suggested for the other communities but ignored for Indian River and Gold Creek. (5)7th Paragraph -This is a poor assumption and probably invaled.An Environmental Impact Statement will have ,to be filed since it is a major issue and Federal land is involed.The preservation groups will push this.Even though the road doesn't tie into an exsisting road,it does tie to a public transportation system -the Alaska Railroad.The US Borax case in Southeastern Alaska is a good example.Their request for a temporary ~oad access is still tied up in court even with a EIS filed. The second assumtion is wrong also.The Native Corporation will bear pressure to use the road for access and development of their land. (6) @page (1) 8th Paragraph -This assumtion is correct.'!':-le .;a~ivas ~·:ill :'eap from the benefit of public funds spent cn the ·:'evelopr.::ent of the road.It is assumed their not putting up any funds for the construction therefore their desires should have no bearing on what route is selected. 11-32 Recommended Access Plan: 1st ?arag:-oaph,2nd Sentance -Again this is a invalid assumption. Plan 11,the Denali route,offers the best control over public access during the construction phase since their are no active private inholdings involved. 3rd Paragraph -This is a positive assumption and it would ~e advantageous to apply for the necessary permits ~or either Plan 6 or 11 immediately to allow for the length of time involved to obtain the necessary permits and still meet the time schedual. @?age (1) 11-32 &32 11.13 Mitigation Recommendation: Only four of the seven mitigat~on recommendat~ons pertain to socioecomonic.Two pertain to road restrictions and the last putting the pioneer road to bed.None deals with biological cul tural resources. one to or No attempt was made to develop mitigation recommendations for the Indian River Remote Parcel or Gold Creek.Th{s sbould be addressed. No attempt '..laS made to mi tigate the real problem Talkeetna and Trapper Creek are conse!'n about -:'he population increase.P'.ltting- funds into the community for the additional services needed to 1 l \ - - - - ~~~~~:he :nf:ux of people.does not answer their conserns.It a=~"<·~:Y increases it since the more services being offered will requ~~e a larger ~ocal work force. (2)~~e ~~rst mitigation measure would restrict access to the people t~2t ~ave inholding land along the route.They were denied the semi~ilderness of the area by the recommended selection of this !'"Cute now their ~eing denied the use of the road ·...hich ....as paid for by public funds. (3)Tr.e second mitigation measure precludes the development of the recreation potential the area has to offer. (4)Tr.e Last mitigation measure is fine but through past experiences on putticg a road to bed,the general public still finds ways to use it withATV's or motorcycles thus creating serious erosion ;:Iroble!l1S in the futUre. (5)The 1st and 3rd-6th mitigation measures could be avoided by selecting the Denali Highway route. The second mitigation measure still has to addressed if the recreation potential should be developed or not. - (6)The"dollar figure mentioned for mitigation measures seams quite low in cot=parison to the figures being prepared by the New Capitol Site Planning CollllDision for capital improvement cost.To build just a new school to handle the influx of new students would cost more tham the figure given. ~Page 11-33 &34 11.14 (b)(i)Engineer~ng: (1)1st concession made discussed a complete loop connecting Parks Highway with Denali Highway.No where in the varius access plans mentioned connecting the two highways via the dam sites.So no cocessions were made. (2)3~d concession made is also invaled because of the pressure the Native Corporations will bring to bear to keep the road open. (3)2nd objective retained is questionalble.As stated,an environmental Impact Statement will probably have to be filed for the road. ~Page 11-34 &35 11.14 (b){ii)Biological: (1)The concession made is untrue as to providing parcial public access to the upper basin.The road from either Parks or Denali Highways will open up the lower portion of the basin to the public for recreational purposes.There is a difference bet~een the two routes which ~s been neglected.An all Denali route will open up only the portion north on :he SusitnaFliver which is already being used ~y ATV 's.Whereas,the Parks Highway route will open up both the northern and southern side of the lower basin to public traffic and st:ll retain the ATV use to the north.Overall,from a biological and wilderness retention standpoint,the all Denali route o.;ould be preferable. tfs;'UJ~ (2)!he ~ourth objective ~etained is vage,misleading and ignor:ng the- rec~eational value the reservoirs offer.It is vage because it really doesn't state any pertinent facts.It is misleading since terrain is not a factor in controlling vehicle traffic.The traffic is on the road not over cross country terrain.As to ATV use between Parks Highway and Devil Canyon Dam site,the soil and vegetation is highly suseptible to environmental damage by the off road vehicles;probably even more so than the highlands found on the Denali route because of the deeper and more moist soil characteristics. As to the recreation potential,by mentioning control access beyon the Devil Canyon Dam site,it presents a strong in~ication that the !'"ecreation values are not being considered in the overall project. (3)The last paragraph -The statement "Road management will reduce the adverse biological impacts associated with an access connection to a major highway to a minimum/l would apply to any route selected including the Denali access.Yet it is assumed the resource agencies are Willing to apply it for the Parks Highway route but not to the Denali Highway route.Why? @page {n (2) 11-35 11.14 (b)(iii).Social: The first concession made is not true.Any of the road access discussed to the dam sites will provide access to the lower portion of the upper Susitna Basin.See comments under item 17 (1). The second concession should be expanded to read Gold Creek and to the expected population increase in the Trapper Creek area.As previously stated under item 14 (1),why hasn't any mitigation measures been taken to reduce the impact to Indian River and Gold C~eek area?. The first objective retained would apply for any route selected. By taking the same attitude for the Denali route co~bined with a good land use and resource management plan the biological impacts would be reduce to a minimum.At the same time it will releive Trapper Creek and Talkeetna of the social-economical impacts. (4)The second objective retatined consern of Talkeetna -Trapper increase.See comment 14 (1). does not really address the·main Creek area which ~s the population It is agreed that the all-rail plan would have a greater impact on Talkeet~a since this would be the main jumping off spot for the construction workers. (5)Next to last paragraph. a.If ~good land use and resource management plan :'s developed and applied correctly for the area,the Denali route ·....auld actually have a better biological advantage over the ParkS Highway route.See comment 11 (9). 9 Identification of Conflicts: """ J'-'~_ - flE-...:ft>t:--b.As previously stated under comment 12 (6),the preference of the Native lando'~wrs should not be conside~ed unless they are willing to pay for their share of the cost for the construction.Public funds should ~ot be used to develop a private corporations land especially since no access between communities are involved. /---\ ~::;rable 11.2 (1)The minimized cost criteria for Plan 11 should be changed to '2' ~ating since it is within the $50MM variance. (2)Minimize Biological Impacts for Plans 6 and 11 sht lId be changed to a '2'rating on the bases proper land use and resources management plans can be developed and accepted which will actually improve the envioronment over the present condition. (3)The preference for native landowners should be dropped completely unless they are willing to pay their share of the cost for constructing and maintaining the road. (4)Accommodate local community preference. a.Plan 2 should be changed to a '1'rating since an all railroad route will have a greater impact to Talkeetna area. b.Plan 3 should be changed to a '1'rating since three communities will be impacted. c.Plan 7 should be changed toa '1'rating since three commumities will be impacted. d.Plan 8 should be changed to a '1'ra ting since an all rail !"Cute to Gold Creek will have a greater impact on Talkeetna. e.?lan 9 should be changed to a '1'rating for the same reasons as 'a'and 'dr. r.Plan"10 should be changed to a '1'rating for the same reasons as 'a'and 'd'. g.Plan 11 should be changed to a '3'rating since it satisfis all local commumities. 10 Not mentioned is the assumption the Devil Canyon Dam may never be built.This has been mentioned as a possibility during several public hearings.If this could be true,them it should be one of the major factors in deciding which route is selected.What ~ould be the varius cost per access routes if this happens?How would this change the social and biological impacts,etc.?All these items must be addressed before selecting the perferred route. \ C=.~)Summary: From all indications,the report in its decision making is slanted one way.There are nume~Ous assumptions made that apply to all routes yet they were directed to a particular route and ignored on ~he others This has a tendancy to mislead a person not fully knowledgable in dealing with the whole parameter of land use management in making a selection of one land use item over another. Land use and resource management planning was not injected into the process of selecting a preferred route other than road management for the Parks-Highway.In all projects of this size and nature,it is probably the most important function to be carried out prior to making a decision along with the safety of the structual ~ngineering design and economical feasibility study of the project. The report lacks sufficient detail information for making a rounded out conclusion on the.varius items discussed in the selection process. ~ore wildlife data could be gathered a~d analyzed but it is questionable the additional funding is worth the effort.Overall, the environmental conserns on the wildlife and fisheries are not that great either for the route access,the impoundment areas,or the wildlife and fishery down stream from the dam sites.Any additional funding should be directed toward a land use and ~esource management plan instead.The plan should be developed by a field oriented multi-resource planning team with representation from the private landowners being effected.and not by an one resource oriented group or desk personnel.As a minimum,two years would be needed to develop and approves the plan.The plan could be incorporated into an Environmental Impact Statement. Based upon the environmental data presented by ACRES,using proper assumptions for all routes,injecting the comments made on the varius items inclUding a good land use and resource management ~ractices.and the possibility of the DeVil Canyon Dam not being built,the Denali access route (plan 11)would be the preferred route. Plan 6 would be the preferred route if there is anquarantee that the Devil Canyon Dam will be built. 1 i - .- .... - .... - UNI T1:0 ~TATES DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Adminiscratiol iVa:io,-:.:=l /·!c.~-t.,ne...:'i3her~es 5e:'"Ji~e ?=.SQ:;:l668 Jun €(::l,A Z..::;,":.:.:J 980,~ STAre·!EUr :"OR AU-SN'\ro..iER AL'THORI'I"[ EOARD OF DI~EC::OPS ~.nc~orage,.Uaska April 16,1982 by RJBERI'~v..1"C~[ REGICNj\L D:rnEC'!OR NATIQN1..L MMnJE r"ISHERIES SE:RVICE Juneau,AlasY.,a T:le Natienal Marine Fisheries 5eIvice n~!FS),within the DeFart::t"er.t of Ccrnrerce,has Fede..1'Q.l responsibility for marine,estu,arine,and a"laciraI'OUs fisheries.several laws,includi."1g t.,'1e Fish and ~';ildlife CoordL~ticn A~,reoui=e our ace..,C"1 to assess t..'1e i..TTDact of water res.--u=ce de-lelocre.."tS on fisher;resources.Reoulations of t:.l-).e Federal Enercv P.ec:ula'to~v"Cannission (I:E..:'!:)soecificall';:-eeuire acolicants fo::, -*-'*'............- lic~se of a ::ujor hyd...""Celecttic ?roject to consult wi:..1o:. ~:'!;S and respcnd to t..~seconcerns or rec:::::trn"e.'1Ca~icns cur age...,cy :eeLs arenecessarl to protect fishery resources.Our responsibilities ear a..'1.ac..-arous fishery resources have resul ted in >:.':e ce'.relq::rne..'1t of considerable t-1r-!FS e.~..ise in addressingt..:,e ;:otent':'al i..-npacts of hydrcelec-:=ic facilities en the sal.1'C.-'resources of t.~e ncr'"'_:..:-....-estern u.s..'!':'.e Nr-!FS ar.d its p:,er:...ecessorager:.c:y,tb~5u=eau of Ccmrercial fisheries,has been a(;l"..,ively involved in efforts to St'l..lCy ar.d preserve sal.m:::m t"'.J."1S to t.".e Cclmlbia Ri'ier basin over to'1ree der-ac.es.t'J"nile the C..l.rrent sco;:e of cur invalverre.nt with hydropo..:er developrre.n~iJl Alaska is considerably less ti"'.an in the nottbwest states ,'Ne e.~t.t.o draw t;.'"'Cn cu=...:-:.-:::-~.I c:ryverall e:q::ertise and involveTe.'1t wit..~suel-). Cevelc;m:."1ts c.uri."lg ow:review'of the Susit.....a cam prq;osal. I \'1e re<:CCjnize the requ.i.::'e:rent placed upon the Alaska ?a-.-er Authority (APA)to sul:::mit recutlienCations to the Governor and the legislat\1re on a future course ofacticn rega-""Cting the SusitM project.~.ccordingly,......e appreciate't..'1e need for APA to have resource age."'1cies t opinions . available for consideration at this tin'e •.we feel,OOw-ever that it is M ~ p::etature for ~~!FS to give a definitive evaluation en the acceptabilit:'f of the project \.ooI'it.'respect to e.'1erS".f.!::e."'1efits versus fish losses.It. is rrore at.-"Prq:,riate t.he......-efore,that we c.escril:e our basic e.~tions wit.~the cccrc.i..,ation precess and our ge."'1e..~l envi..-ome."'1tal concems. First,I wc~ld lL~e to al~hasize ~~e neec :0::a c~r~ie;.si~e UI".c.ersta.'1d.i.'1<;'of tb.e i.r.;:cr-...ar:ce of fisr:e::y ::escurces ',,:it.,;":in ':...":e :;r:'oject a:ea.The Susit."1a !live::eraL'1age is 2..'1 '~"~~errely ?ro::iuc~i'.Te sys;:e.rn \...it.~ an annual sa1Jron r"~?rcducing a large ~erce..'1tage of t:.~e c::mrercicJ.l Cook Inlet cate..".These fish are.vert irr:'...o~...ant to bOth t.1..,e cc:rrme::::ial fishing industry and the sport fishing sector.Sa.lrrcn a.."'.d 'several resident s-~ies such as rair..t::a.v t.=cut,Colly ila=C:e..'1 a.'id grayl.L,g are sought by SFCrt fishenren.The ':ish of the Susit.'":a Ri'J'er also cont=ibute to t..'"1.e ecosvste!T1 of t.~e areil bv ::rovidina :co:i to ot.."".er :':'sn, birds,and wildlife.Here in ,Uaska.our fishe.ries :-eDresent cart of a.. lifestyle whi~~,while diffi~~t to desc~ibe and LT.DOssible to place...,-...... value on,is no less real, The ~proposal will br.?act t.~ese :iste.ries.~~~~le not all of those fish utilizing the syst~'...·ill te cirectly i..:~acted,'...e ,.:Z'e conce.tned about any loss of fisne=ies resc,-,=ces. Cnly '....ith an L'1-cept.~underst:.a!".d..:....,g of t..l;e :ish ar.d ar,t:'ci;.atee:"-:-;::aets, can we fully weigh t.he costs associated ·....it.,;~hydr·:)c.evelc-;:rre..'it,,=..-:d p:rhaps,fi..d ways to accanrcC.ate ::Ct.~.It is i.-r;;:o:-~'1t,:.~erefcr;t.:"'..et fisheries research and studies ~ot cnly ice..'1tifyt.'e s~ies 0::~sn oc:::upying the Susitna.d...--ainage anc c.esc::-iJ:e t.~eir ecclcgical characteristics and n~.....s,but also ic.e..'1~i£y areas of :"'-r;::act .md :reas-.:=e to avoid er mitigate t.."".cse L-r.;:acts. The necessity of obtaiI'li.'1g CCT1pre..l-..e.'1si';e e..'1viror.rrer.tal data is also recognized by the FEOC in their requuere..'1t ::.'1at such ~'1ior:L'ation be specific,aCOJrate"a..,d sufficiently quantified to c::;nvey .:l ::recise ?ietu-~of b~project:ar~its ?rcbable effects. This leads us to my second ::oint in.wt...ich r ·....auld li:,e to disC'.:ss several aspec::s of the Susi~"1a Cam ~roject:~~t are 0:c::nce~'::J our lJcn~/· 'l11e Susitna Hydroelectric Project Feasibili t::'J Peport.has l::ee.'1 preparee. to assist decision makers by c.es.....-=ibing t..~econc:mic,social a..,d en.viror.rre."1tal conce.....-r.5 associat-ad '..;it.,;"~e project.L,t.:...is regard t.l..,e doc1Jment e:etiorms well.Hc'...ever,':.~e :eas.iliili':y Re;:ort :'s 3.150 I ......... inte."lded to provide the basis for application :or licer:se ':0 t.1..,.e ::::.."'IC.~,_I The rego..l1ations of the r.E..'C are clear i..'1 -=escribing t..l;e L-r;:cr-•..aIice oi including adeGuate e.~L'"'Onmar.tal data.i.,t.."".e lic~se .3.~lic:::t'tion. E'Urt.'1er,they requi...""'e this L'1fonration ~o te ?rovicee en a level ccmne."lsu..~te wit'1 t-"lesccce of tr2 oro~~.~.t t.,is ~:..~'....~e co ::01:feel t."1,is level of detail has been reac~ed.~';it.'6ut tt.e res..ll':.S ot - acCi':':"or~l st-..:cy L,seve=al a=eas,var:'cuz as;:e'.:-:s of :;:e :::cc;:csal '..,.il2. :::e ;:ccrly cesc::i.!::ed or unce=stccC.~ese ccfki~cies do not i..'!;'ly ~"'.at t..:'e Feas.ibili~'~eror::.·..;as irrorocerlv ore=a=ed or :Jrese!".teci.?.at.~er,~"o...-"."".=..--c·n·....e·1 ;"",';~ea·':'':I"'\:-:at~'''n'",;.",i'~;"le :'S of t.l-,is cia"':::>-....1 ..--.-_........-".....~...............J._....~l __.-~----~_.'-•--.. One area of L:.::l.i ted i..:1.fc::::ration :'n t...~e ?eas:'=i.li ty ?.e;:or:::eals ',vi ":...'1 ~'1e effec':s of t=Ost:?roject flews en the fis::e=ies rescurces.The Feasibil.it'l P.ecort discusses the i.n=ot"tanceof sice c.'1annels and slcuchs Cet:-ee.!"l Tai1.:eetna and cevil Canyon.'These areas a=e heavily utilized -by s-'t:4 ning ar.d reari..,.g saLmn.The ~ct of projectflo....s to tr.ese areas will dete-~~,e ,to a large a~tent,the fishc~!i.7.pact at~ibuted to tbe ?roject.'n-.ese.sloughs ti'.e=efore represe..,t an area requiring consideraticn of ~te."1tial mitigation and/or e.":-oancere."1t rreasures.To date,less ti'.an one eighth of the s ide channel and slough areas have Ie T eee."1 S".l-""Veyed.f\1rt.~,the impacts of various flew'regi.res on t.l1e habitat are unkno,.,n ber...ause t.'1e hyd.""Olcgical and ecological relaticr.ships bet:'....ee."1 the n-a.instem Susi~-,g,and t.'1ese areas have ~ot bee.., ac.equately st':'died.An in-dept.h.study of projected flo....regin'es is r.~-ed.'I'l":e results of a ce:rrpre.he."1sive In-St=eam Flew St-..:Cy '",culd aEo.... a balar.ci.r.g of fish habitat lOsses agai.,st:~-er generation,C"_"1.C ot,;.L;er mitigation ?Ossibilities t .•'1at CC'I..lld ::e e·lalua~ed. 'I'es;:e=ature c."'.ar.ges wit.h..L...t.~e Susit.-.a R.i·,,"e=are e:-c;:ec'ted to resul':.fr:::m CCI"'.st..~ction and operation of t."ed.3r:'.s.TI1esechan'ies could ;>resent i::ct.~positive and negative c.:..:anges ':.0 :ish ::coulat.::.C1".5.T~e APA ::as used a.car:puter !i'Cdel to predict and describe these c::a:.ges.C~~tly, wl!Co not believe a l".igh level of confidence e.~ists b t.he proj~ed jc ., F:Cst pro)e-=t:':.en;erat'..::=e wit..,i."t.h.e ~...o reser,,-ol.rs,t..:"'e Susi ':.."'2 liai..'1S~e..'":\,C4"'ld t.:.,.e side .char..~els and slc1.:ghs.'!'her.:-al changes rr.'l'! prese."1t signi":ica."1t prOblems ':.0 sal!rcn,and additior.al st·c:dy '",ill te necessary before possible i:npacts can !:::e adequately cefir.ee. '!:-:e Fea-swili':.'!Rerort states the cbjecti'le of t.he Susit.ia :::':"~g2.':.icn effort is t.e achieVe no net loss.Toac::hie'.re t.\....is <;cal,s;::e.:i:':"c stud.i.es ::lUst occur \·;hich will Cevelop ::-itigation options icenti':ied i.."1 tbe :easibilicy P.e;:ort.i..~cO no'!:::elie-:e ':.\".a~a mi:'':'g~-:':'on ?1~"1 ~"1 ::e develc{X."d,L'\.l!Jcd upon llvailwlc inform1f:.ltjn"N'hich '"auld ;,.:\ci:Jfy th~Ie! rE!GUi.r~i1ts of to~FEte.Basic to any ilri.tigaticn plan is a ccmprehensive ut'.derst.anding of the rescurcc and.t..~e ;otend.ll iJn?let tr.e project will prese.i1t to t.."1e resource.Ac;ain,'N~do not l:elieve t..us level of Ul"'.ce:standi.,g has bee."1 reached. The ~.regulations cence:=1:L-:g lice."se ap?lic~tich :cequi:-e 3.reFOrt that Cescri1:es t..~e fish,...."ildli;fe,and Cotanic3l res...~ces..!:'.ic=::ation ~~ 1.'1 this reoo~is to ir.cluc.e temeoral-a.~d scat;ical dist=ibuticns of r J cer"'..ain fiSh S"CIeCies.As sam saJ.-ron •....it:~theSusitna ?-i':er have life C"lcles of five"or ITCre ~·ea.rs,it woulc.See'I'l reasonable to allcw at least ~us long :cr f:"sher'!5-:.~~cies.Tt:':L~r:f~,t...~c ~i;:r:e!:":Qs :;t·...:die5 sF,:.--..::..:ic t.o r.::e .::".PA ?:.-c::csal.have cc::,z=cd :::-cr'.l';"cr.c :ielc se~sc:-..:!:t Ls :;.ot. r"eascr:a.ble ~o ass~t..~at.such ~,..1i:.bt""c~:'':''J.,:ed 3~ii.-:g :'s ac~..~ate f=r ?rc;:e~c~ac-:.e.riza.ticn of :rescurc~s.?'~)r ~'..:.:~.rrple I ~L"·'_k 3al.TO~e.:,,:.hibi~ ~t=.v·O year cic1e ",,~·it...'e'lt~"1 year =-~:;::f~irLg :71.:C~st=~nsc=t.~a~t..::"e CCG yeazs t""...14'S i.4 U£:~::-Cock L"11et.;'.t t..:~i3 :.i.iC,f,·.:e :"1a~:'e ~.o i..:::o=~~ion 0:1 t.~e si=e of eve.'1 year pi:'_i.:.::a.Lmn r.::;.:;::c t..':e u==e:.-Susi::.::a 0:'-':.~e az-eas of the P~verL'1 ~~~c~t:~se ~ish ~~wn.' f,ole feel it is u..~eascnabie to disc..:ss :citigation cetails tefore adequate kncwleege c=t..':e :ishe:'y r-eseurces'~<ist.s.TI-.e Po..."er ,;ut..e~o:::"i '::j has tee..'1 L"l.for.red of ~ese concerns and dau caDS I and of t..~e st.ees :;ecessarr t::> cot::'ect t."1em.Our ace..'"l.C'J'has orevic~siv st.at.ed ~..at t.."1e"envi=orI:'e."':.tal data available frcn Pr.a.se I stUdies ~.;ill net sUF?::Jrt a.'"l.adequate evaluation of projec:~c't.l'le c::mti..nue to recQ'rTl1e..'1G 1:t'.at t..l;e antici?3t.ed date Ear suCrnit.tL'1g the li~~~se a~?Li~3Lian =e celayed ~o allew aeciiti.cnal data collec--icn. It is ou=~-~erstar.dL'1q t.~t ~~c=a:~lic~~se a~?li~~tion Ear ~~e SllS':'t..~;:roject.wil.l seen =e available :cr reOf.r:'f:!.v"~~Te are c~r6ce.=::.ed t.".at ~~e a;:?licaticn ·....ill :-e:lect t:.e sedcus 'iefic::"e::cies 'de :--.ave F; :rer~.-ticned.If our :-e'vit?v shoC'n-"s :"h.i.s :8 =€~.'2 :3.se,·...re :~cl C-t:=3..qe:.C! will have ~c alte-~tive but to =~:e5~~~e :~~to =cj~~~~e 2.ppli=aticn or di.ra~t...~t t..~e de:ic:-er:c:'es ::e -:~r-::"e:::":.E.c."Ie ·le-::!~C:1 cesi=e to avoid t.."..is sit~ticn. Fir'...ally I I ..auld i.i.1re to close my st..::.te..'!'e!1t '....it..'1 a leek i:C"•.J2..:::"Cs t..':e ~~ture and a 'NOrd of e.'1ccu=agE!'l'e!".t.T:-.e 1..ll,ccr":3k:..;:g of an e.'1vi=::r.rrental st~l :cr a prcject such as Susi~;.a :'5 a..T1 ~Cr:rc;U5 ':.2.5k..L~c==:-di..;,gly I t..=.e POoOle.r Aut.":.ori ty has initiated a.':er:y cO.~i!'e:-.e!',s~ve se1:'ies of S~i..:O~es whic:'whe.'"l.o:::rr;>leted '...ill ?rcvide us ·....it.\;.a better '...l.~c.e1:'st2.,d.L::g Df the f'..lll range of project related ef:ec~.Inc.ced,it rr.ay !:e ?)ssi!::le tQ CQns\:.-~C't.ar.ci c-...erate t.":.e dams i::s~;::h a.·.va\'~5 ~:l achieve t:',e Authoritv's r;o net loss coal bv rniticati.lcr fisl":eri ~.::'I.c't.s,a:-.c./or ::'1. •J '"...~.... enha.llcinq fisr-.e1:Y ha.bi~t L'"l.cer...ain areas. r knew the !k'..rr'd of Ouctors ,'pprcci.'t0~'t".hfl ir.r-I')r.t.,r:c~of cur :i::>h~:.-i..::;. I hope I have ccnv~.red to you ~';.e l::er.efits of detailed $tuciies to obtain essential infoonation.In fcnr.ulating its reccmnendaticns to t."1e legislature,I since-1""E!ly e.'1courage t..!le 30ard to consieer t.."1e c=itical need for this info:aration a.Y1d t..~i.It;:lications of 5'rcce~di..,g in its abse.'1ce. -- - - - April 16,1982 DEP AR.'l1iEN't OF NAIURAL RESOU1lCES IS IESTDfONY IO TIlE A.LASKA POWER AO'IHORI'I'Y BOARD OF DIRECTORS I appreciate the opporeutli.cy to provide comment.s to the Power Authority Board of Direceors on che Sus~tna ijydroelectric"projecc.I regrec thac, because of ot.her comm:itments in Juneau,I am unable to personally del.1ver these comments. At:the inv1.tat:ion of the Alaska Power Authority.che Depart:menc of Natural Resources has been working informally with the Aut.hority over th~last two years to help formulate and carry oue studies ~esigned to answer che questions which ultimately "'ill ~etermine whether the Susicna Dam proposa~are feasible.!he purt:l0se of chis t.as t1mouy coday is ~ofold:Firse.to identify Susitna ijydroelectr1.e issues Chat:are ",ichin the sphere of DNR I sauthor:l.t:y;and second,co azake recotllml!nda- tions to t.he Board of Directors on the continuation of pcojecc develop- ment..as requested in the January Z6 lett.er froa.Mr.Conway. SUSlmA HYDROE!.EcnuC REUTED ISSUES WI'IRIN 'OlE.PURVIEW OF nIE DEPARnc..E:N'I' OF NATURAL RESOURCES the Deparcment:of Nacural Resources ~be required co Make decisions on tyO major facets of the Sus:l.tna Hydroc!lectr:ic Projece.!hese are: 1.DNR responsibillC:l.es for water appropriat:l.ou (and.possibly inst.ream flow reservations)from the-Susitna River. 2.Ri.ghts-of-Way permits for access int.o che dam s:i.tes and cransmission line routes.Ot.her land use-permits for access to construct.ion sites, gravel for-const.ruccion.and other land use related needs as they o~' on state owned lands. The role of the Departm.enc of Nat.ural Resources in ",at.er right.s appro- pr:uu:ion W'til be an adjudicatory one.According to Alaslc.a.Statute 46.15.080 (b),the impacts of water approp~:iation au thepubl.1c interest. shall be considered during adjudication.Areas of public 1.nt.eresC are defined in.the Statute as follows: 1.!he benefit.to t.he applicanc resulc:l.ng from the p~oposed appropr:!.acion. 2.!he effece-of the econom.1c activi.cy resulting from the proposed appropr1.ac:Lon. 3.The effece on fish and gameresource=s.and on ?ubl.1c recreat::i.onal opporeuai.c:i.es. 4.The effect on publ.1c health. 5.The effect of loss of alcernate uses of ~acer chat ~ighc be made ~ichin ~easonable cime if not precluded or hindered by che proposed appropriation. 6.Ham to other persons resulting f=om the proposed appropriation. T.The intent and ability of the applicant to complete the appro- pria.tion. 8.The effect upon access co navigable ~aters. The Dlilt ';Jill be looking to the FeasibUity Study data and infor.na.tion to describe the relationship be~een various streamilo~levels and ho~chey ~ill iQpact fisheries and aquatic habitat downstream.Thus,from this Depar~eut's perspective,instream flo~studies and the relationship of various flo~levels to aquatic habitats and fisher::l.es resources ate Vital.The studies administered by the AEA ....ill be the fundamental. source of data and information used by DN"R cO malte the public interes t findings described above.We are eager co revie~and comment upon the present and future plans for instream flo~studies.To date,';Je have not been provided an appor~unit7 to review or comment upon the instream flow scudy approach. The access to the dam sites and the policy surrounding the ~~tent of access after coustruc~on will lead to one of the most significant ~pacts of the project.The Power Authority has stated chat the permit for use of a "pioneer road"is needed'in 1982 (before a.F .E.R.C.permic is issued)if che pOYer is to'be on.line eleven years Lacer.One signi.fi.- cant issue is the possibility of the ~onstruccioI1 of a road to the. proposed dam sites and a subsequent decision by che state not co construct the dams.It ~ould appear to be in the best interest of the Power Authority J the land managing agencies.and che public to idencify other.--p:r alternatives ....hich will allo~the necessary access co che proposed dam sites in a manner ~h.ich prevents irreversible impacts.In order to prevent this issue fr~being a pOCential delay in progress,we recommend that the APA ta.ke the lead in convening'a multi-agency.mulci-disciplinary effort to accomplish.the goal stated above. The second issue is the long term land use iMplications of access co the proposed dam sites.The provision of accesS to the dam siees should not unwittingly dec.eDl1in.e the types and e.~cent of land use impacc.on the jG.'1 surrounding lands in che upper Susicna Valley.Carefu.lly decerm.ined access route decisions could result in a muLtiple purpose route whi~~ could facilltateand enhance ocher uses of the surrounding lands.In order Co accomplish chis.che dam access route decision should be made in conjunction ....ith surrounding land owners,land managers,and the general public.As on the other issue above.the DNR is wi.lling to participate cooperatively ....ith ~~e Alaska Fo~er Authority.other agencies. and che publ.ic to resolve chis matter so that'it does noe becom.e a . pocencial delaying factor for che proposed project:or a future manage- ment:problem for land owners and managers. ~, - SUMMARY AND RECOMMENDATIONS !n summary,che Deparcaent of Nacural Resources has three recom=enda- cians: 1.the Deparc:enc supports continued studi.es in the socio-ecanomLc, technical,and enviroameutal areas.The preliminary ',Jork accomplished so far indicates that che project is technically feasible.Further ',Jork is needed to establish the info~ation and data for wacer appropriation and f~hery tl1icigation.Addi.tionally,we recommend further work on ehe timing,route and condicions of access to the proposed dam sites. 2.With respect co the question of tlhecher it is desirable to submit an application to the F.E.R.C.on SepteMber 30,1982,',Je offer the following comments.The A2A Board of Directors and the scaff should carefully ',Jeigh the advantages anci disadvantages of submi.tting the formal applicacion on September 30,1982..If that course of ac~on ',Jould res~c in che APA acquiring .~F.E.R.C. permie eo construct in ehe most t1l:l.ely and econotlli.cal way,then that course of action makes sense.Kowever,if on the ocher hand, a formal appl1cation would resulc in delays,increasedpocenC1.als for licigation,and a hardening of adversari.a~roles bet~een the UA,other agenc:i.es,and other interested parties,then'the.possibility of these delays should be considered.We believe that the ~A Board and the Sc,a£f are in the best position to eva.luata.pros and cons and to deter.nine whether a.F .E.R.C.application on September 30,1982.,is desirable or aoe.From au:'more narrow agency standpoint,DNa is noe opposed to a F.E.R.C.application so long as our agency concerns and responsibilities can be fully and openly detel:1lli.ned througn the traditional intervenor process. 3.We cOtl1tJliment the A2A 30ard of Directors and staff for·encour- aging inter-agency incerdisciplinary approach to identify ',Jays co ilI1prove the coordinacion and ulcimaeely the results of the feasibilicy seudies.Webelleve chae serengthening tbis approach will facilicace a more cooperac~ve and constructive role for chose agencie~~ich have respoasibil1t1ea that require them co take aetion on the Susitna Kydroelectric Project;.SpecificallY,we recommend strength- ening and enhancing the role of a group similar to theSusitna Kydroelectrfc Steering Committee '.Jhich has been providing ~or:al agency com=ents to the APA on this project for the lase ~~o years. Testimony presented to the Alaska Poyer Authority Board by Deputy Regional Director LeRoy SoYl,U.S.Fish and Wildlife Service,on April 16,1982,concerning the Susitna Hydroelectric Projecc. !he mission of the U.S.Fish and ~ildlife Service is to: Prov1de the fe.cieral.leadership Co conserve,'protect,and enhance fish and ':IUdlife and their habi.tat for che cont:U1uing bene.fit.of people. You might ask~therefore,':Ihy is the F1:sh and ~llcU1.fe Service concern- ing itself ':lith a Stace energy project? The Susit:na Hydro Project must be licensed by FERC before construction begi.IJ.s.!he Fish and Ilildlife S 'Coordina.tion Act requires chat: f:1.sh and ':IlldJ.i.fe conservation be given equal consideration Yith other features of a proposal throughout the planning and decision processes. FERC is fu.r1:her required to consult \lith state and federal.fish.and vildlife resource agencies to deter.:i.ue "'hether there U1.ll be proj ect rel.ated lasses of fish and.\llld.l:ife resources. The Coordinacion Act and Section 102(2)(3)of che.Natioo.a.l EnvU:onmental. Policy Act both requi=e: (1)A description and quantliication of che existing fish and ~dli£e and their habitat ~thin the·araa of project impaccs; (2)A description and quant1fication of anticipated proj ect ~acts On chese resources;and (3)DeJ.i.neacicn of speci£iCrUtigation necessary to avoid,mini:c1ize, or compensate for chese impacts. The Fish and ~Udlife Service has revieYed the draft reasibUicy report: "'ith respect co its area of exper1:ise.Deficiencies are readily apparent vith respect:to a.l.L three require:::aents.There has been a failure to quantify the habitat types present,anticipate che impaccs or ta identtiy required.lDitigacion.All of chase deficienci.es are directly realted to the unrealistic tae 'constraiJ1cs placed on data collection. Some of the specific deficiencies ':Ie have noted are~as folloys: (1)Terrest:rial.s01dies.have focused on che iJlq:Joundments and their immediate vicinities.The assessment:of y1J.dlif e and fishery ft G resourCeS must:be extended.Co dololtlstream areas,cransmi.ssion and access corridors,and areas of sec:oa.d.ary or indirect: mpac:t:s. (2) (3) (4) (5) )" (6) Q (7) (8) -2- The terrestrial studies have been qualitative..Quantification, through an acceptable methodology,is essential to the evaluation of habitat values,the probable i=pacts and the selection of appropriate cdtigation.UA has stated its obj ective as "no tJ 1I"'L net loss.It WichouC methodology to quant:ify either losses or ~tigation there is no yay to assess Yhen this goal has been achieved. Fisheries st:udies Q,ave.been conducted for only one year.A ,study of this scope:is sufficient:only for a preliminary evaluation of the impacts and to provide for refinement and focusing of longer ter:L studies.One year is not enough time to provide ehe data necessary Co fully descri.be the resource. Any'attempt to assess impaccs,or p~a.c.mitigation ~1thin the . concexe of the license app~ic:ation vould be ~equace. There are inadequace data to descnbe the relat.iousbi.p bertJeen vari.ous stream flovs and the productivi.cy of fisheries and aquatic habiuc do~tteam from the proposed Dev'1l Canyon Dam. A.fully th.ought:-ouc instre.am flov study vould provide the quant::l.fi.ca.tion necessary fol:'any impacts evaluacion and Cli:cigacion.planning.Without:.this 1u.format:ion any evaluatioo. of proj ect:1=llpact on fishery resource is missing an essential compon.ent,and effective mitigaci.on planning is seriously hampered. Anticipated \Qcer temperatures and.curbidity levels in the reservoirs and downstream from DevU Canyon have.noc been L..v) sacisfactor:l.ly invest:.igated.An adverse temperature regime (- has severe iJ:plicacions for che fisheries;dmmscreamfrom Devil Canyoa.as ~ell as any potential fishery iJ1 the reservoirs. !he cerrastr~~pacts assessment and micigatio~options put forth by the consulca:ncs are quil:a general,not.sufficiently thought through,<U1d provide an inadequate bas1.s for a full ~)..fIJI.,,)...; discussion of the proj ect:.This is directly related t.o the lack of an acceptable methodology for quant:l.fication. Public access and che mode and route of coo.structi.on access need to be fully addressed w:Lthin the con1:exc of mitigation. The environmental consultants have recognued that publi.c access poses the greatest:threat:to the terrestrial resources, princi.pally through disturbance.It is completely incongruous given this assessment and A:iA t s goal of "no net loss"that the consultant s~ld attempt to divorce access from consideration of Illitigaci.on as they bave done. A pioneer road canstruct:ed prior to FERC licensing.is proposed. The sole purtJc)sa of this road is co facil.1.ta.te proj eet:const::uction. We do.0.01:expect:.FER,C approval for this prDposa~.FElU:cannot -3- give ics approval yithouc an environmencal impacc scac~enc. In addicion.habit~t losses susca°ined ousc be juscified by che need for a project.The need is.proven ~hen,in the case of a power facility.the license is issued.?"rior to thac paine, there is no proj eel:and there is no habitat:degradation that can.be just:i.fied. ~e believe that alt:eDlatives to Susi~a mus:also cont:i.Ilue to be studied. Comparison of tradeoffs for fish and Yild1.i.fe resources att:endent to che North Slope nacural gas,Cook ~et ~atural gas,Beluga coal,other hydroelectr~c generating alt~t:ives,conservation,and other options . have not:been evaluated.to an acceptCJ.ble level.Cant1nued st:udies ~oul.d al.lov for a full evaluation of the envizca.mental.costs. the A2A proposes to submit a l1cea.ceapplicatiott Co FERC·au September 30,1982.The appllca.t:1on.~be based on the-feas~bility report. Given the numerous de£ic1ences I have just:noted a submission on the· proposed date 'IolQul.d be premature. The Fist!and YiJd]jfe Serv~c~bas had min1ma..l involve:l.en.t TJith the Susitna.proj eet:during the last:Z and lIZ years.Ye believe 'Io1e have cousiderable.experti.se to offer APA in de"re1.oping an adequate license application.for submission.to FERC. One particul.ar area in.yh.ich 'Io1e believe we.could add substantially to the study is in quantifying the fish and tJi.ldlife data for eval.uating impacts and for.m.lating ndtigation plans.The Service's Habitat Evaluation Procedures 'Io1oul.d proVide a framework Yithin ~'hic.b.habitat vuue can.be evaluaced.Thi.s methodology 'Io1as used :in both the Terror Lake and the Bradley Lake Hydroelectric Projects.Our Incremental.Instream.now .Methodology allows for the quaa.ttiica.t~n of the ancicipated.impacts of proposed flow regimes on aquatic habitat.Mod1£icat10tt woul.d need to occur to this methodology bur.tole fully believe that it provides the groundvork upon TJhich to buil.d..It was util..i:ed in th.e Te....-ror Lake Project to evaluat.e ±=pacts and for.mulate mitigation oe.asures to protect. che fisheries resources. The Board sho~d rea~ize that the very decision t.o file the application 'Io1ith FERC 'Io1oulA automat.i.cally change the relationship betveen APA,its consuleauts,and the Fish and llUd.li.fe Service.Wit.h the decision to file.our attention llIUSt immediately focus on the licensing process.~e no longer 'Io1ould have sufficient t~e and manpower to assist.and provide expertise to A:PA and its consultants.~e would expect that.ocher federal.agencies 'Io1ou.ld be s;miJar~y affected. ~e recommend that.the decision 'Io1beche.r or not to submit an application to FER.C should be deferred until.dat.a gathered this year has been evaluated.We lllUstbave a be.tter unciersc.anding of the fishery-habitat relationships;a.lDDre·thorough underscan.ding of the re.l.a.ti.onship of the aquati.;:habi£:.at:to flovs and temperatures;an underst.anding of 'Io1ha.t the terrestrial t:radeoffs are;and a great.er comprehension of the rese1:"roirs' temperature and turbidit.y regimes. - ~e greatly appreciate the oppor~uaity to present this testimony and look forward to a continued ~orking relationship. U nitec States Department of the Inler10r 8UR£':"U CF L.AND MANAGC::~ENT A~choc2~e Discr~c:Office ~700 ~~s:72nc Avenue .\ncho:~ge.Alas~~99507 Alaska Po~er Authority Board of Directors 334 ~est Fifth Avenue Anchorage,Alaska 99501 Gentle!l1en: 2920/0LJ APR 1 ::.1982 The Bureau of Land Manage!l1eot appreciates the opportunity to address and comment co this board on the proposed Susicna Hydroelectric Project. Curt ~cVee,Alaska BL.~State Director regrets chat he is unable to attend and comment today due to other commitments.I am Dick Vernimen, Associate District Manager,BL~Anchorage District. Since the Anchorage District will be the office ~~ng che =eco~en­ dations on che project I ~ill be speaking from chat position. The 3L~'s charge as a multiple-use agency is to alloY the use of the public lands to its highest capacity and values and to mitigate ~pacts where possible.In the case of this project we are involved ~ith a mixed land pattern requiring us co act as interim land managers in regards to unconveyed Native and State selected lands.Our charge is the same but the land status requires more concurrence concerning decisions on ~hat is allo~ed co happen on chese lands. Based on what we know aoout che project coday from reviewing documents and ~eecL.gs ~ith boch ACRES and APA ~e do not forsee any reason ~hy che continuacion or projecc development should noe proceed.We offer che f01lo~ing informacion for your use: 1.Pioneer Road Rouces. As we understand the situation.for chose routes chac originate either on the Alaska Railroad or the Parks Highway,the Pionee"r Road lJould have to be constructed during the years 1983~1984 in order to arrive ac improved access during 1985 and ~arly 1986,~hich would then prOVide for a state of continuous access from the middle of 1986 onwards.The Pioneer Road concept requires road rights-of-way and =elated permits during che year of 1982 ~hich is prior to the ?ERC licensing process.There are obviously several proble~ with the Piqneer R.oad concept.As ~e noy understand the situation,ihey are as follows: 2 1.Early construc=ion of che ?ioncer Road would have co be permitted by a B~i right-oi-~ay c~at ~ould require an environmental impact scatement separace frum those documents no~being prepared tor che project.Approach- ing the Pioneer Road Project in a separate EIS ~ithout evaluating the antire Susit~a Project may lead to a legal challenge of piecemealing a bigger project.In ocher words,we could be challenged that the road is merely a part of a larger overall hydroelectric project· which should be analyzed at one time. 2.The Pioneer Road would deviate from the location of che final access road particularly on the route south of the Susicna River betyeen Devil's Canyon and the Watana site. 3.!he Pioneer Road concept requires decision making by the Cook Inlet Native Corporation,State of Alaska,and the Rureau of Land Management,prior to licensing by FERC.We are very much concerned that a decision on che pioneer road may lead co serious anvironmental and economic consequences prior to the actual licensing of the project.While it is not likely a FL~C license will be denied after che feasibility of the project has been eStablished,time has a ~ay of changingche values set by many of our past decisions and we as separa.te agencies cannot take the Pioneer Road concept lightly. There are three ocher aspects of the Pioneer Road concept we should oention.Those are:1)ic is very likely a Section 10 permit will be required for crossing navigable waters (Susitna River),2)a Sec cion 404 pe:t1lti.t for wetlands will be required froCl the Cor'?of Engineers,and 3)che decision on che ?ioneer Road concept will be elavated to the level of L~e Secretary of the Interior.All of che ~entioned problem areas t<t1~e cime and,as cime is of the essence,it is extremely important chat,if a route is chosen that requires pioneer Road construction,chat che decision be oade as early as possible and that che application for right- of-way and ocher permits be made to che Depar~nt of '.'Interior and Department of Defense agencies at the earliest possible momenc. 2.Environmental Impacts: We are concerned about che relative environmental tradeoffs that must be made if this project is to be c.onscructed.We cannot at chis time recommend to you a preferred access route and ~ode.There are obviously some rouces hoyever chat pose relatively higher environmencal costs.Those routes are che one south of che Susicna Ri~er b~tween Jevil's Canyon and Wacana and secondly,the corridor paral1elling the Indian River.Also of significant environmental concern is che rouce proposed south rrom the Denali Highway.The Lm:pacc here is some~hat micigaceri by che wescern rouce as opposed co the rouce via Butte Lake.It is scill unclear as co the relacive magnitude of che impacc on caribou posed by the western route south from the Denali Highway.~~1ile we are concerned as co the impact on chat caribou herd,we feel chat the environmental tradeoff i~question is one of impacts on the caribou herd versus the impaccs of more productive habitats in the area of Indian River or Fog Lakes area. From an environmental standpoint,che route southerly from the Denali aigh~ay seems preferrable from the aspect of minimizing disturbance of productive habitat.The route from che Denali,ho~ever,poses a secondary impact,chat of human access to the project area after construction.Public access to the project area is a c~o-edged svord.We recognize that the Watana Project may provide a valuable recreation source for people of the southcentralAlaska.I~is also recognized ho~ever,chat public recreacion can be a very destructive activity.We submit that control of the access, che State Game Laws,and the project management,after construction,are tools chat can be used co lllZnage the a.dverse effeces of increased recreation opportunities.The question of public access co the projece area is a spinoff of the type of access chat is developed for project construction.wnile cany problems are present we submit to you che following conclusion.s: a.Boch rail and road access will be required for construc- cion.We feel this concept prOVides adequate flexibility and logistics during construction phases. b.It is improbable the State of Alaska can construct a project of this magnitude Yithouc some form of readily available public access as a residual product. c.The entire Susitna project is surrounded oy primarily -tYO k~ds of lana ovnership,approximately 215,000 acres of privaee lands,in Native ownerships,and a very large acreage of State Land.The Cook Inlet Region Corporation has indicated they prefer develo?ment of their lauds as a means of generaeing revenue.We can deduce that the State of Alaska likevise is committed co the;development of the highes~and best use of its land.'Ihis land ownership pattern and the respective management philosophies lead one to believe that road access will be supported by these ~very important landowners in the area of the project. Ie is our posicion co work wich you on che projec:proposal in che mosc ~xpediant manner we C3n while working within ehe l3ws ~nd regula:ions placed upon us.If ehere are further quescions concerning our comments please concacc meat (907)267-1246.Thank you. ~~~u~ Richard J~ernimen Associace District Manager ~'-:I' 'E?"".. A•...----..~..::..I ..-.I~United States Department of the Interior 2920 (013) BUREAU OF LANO MANAGEMENT Anchorage D1st=~c:Of:ice 4700 gast i2nd Av~nue Anchorage,U..1sk.1 99507 JAN 7 198Z l'4".r.EXic YaW.d,~.nve·DireC"'-Or A.l.a.ska.PC"M!r Al:rrb.orlf:J 334 W 4th Ave ••2nd ncar ft.nc:h.orage.AJ.a.ska.99501 De.a.:r:M1:.Yauld: The &...'1 has been c:om:ac'l:ed by Acres Pme-""ic:an reques'l::i.ng fotmal c:cord.i.Dat:1on cmd review CD.five Susitr..a Bydroe.l.ed:ric Pro j eC!:CoCUIe.1ts.Cmrent:3 en d:lese .ciocrsnenr:-s c.aI!OOt be accrrnpJ 1 sbed under the gu:L:iar..ce of ti".e ACRES Cocr.cdinatian Pla:i.undJ.a coordinat:ed int:e!:'a.gency a:pprcacb.is c:ieveloped for r~1ie,J and carmenrs.Such a process·h.as been reecmre"'ded by cb.e.SusiJ::rl.a.Steer.....-,g Can- mir:-...re ani is·~t:1J:g "'jf:JI.Jr approvaL !cur recem:let:t:el:3 md briefings have brought:into foc:s several aspects erE ;1'-,>access s t::J.d:r that:I ~d 1.ike co car:mmt:co..T:bose sub j ee:t.areas are Land st:atlJS.Pi~Rcad coocepe.~-...-orment3.l.impacts.and t;i1e piecemeal er:ec::CD.d:.:l.e.prej ec;t:_ Bo efly.t:he land s'C.a.OJ.S 00 t:b.e project;area.has not:dlanged 51 gni fi candy widtin the Lase ~;~•Oe:re -a:re seve:::al.prob lam c:once-"'":'li..ng l..aDd St'.a.t:U.s ~feel should be 'brou.gbJ':tD yot:J:J:at.""'....enrion.Th.ese problems ~are as follO'(NS: 1.1h.e a:w::..~oC'O.Nal:i.ve Coroarat:.i.c:n I 3 ad:m pi st::'ad..ve a:aoe.a.l to &..'1 Int:e:rim Ca.....veja:LJC2 N::J •285 •·J:lich c.cnveyeci 1..m.Cs to'Cede In.l.et: Regioo Inc.(CIRI),c.asefile No.Vts-30-1.has l:e en eti srrri ssed by the Alaa k.a Nad.VII'!C1..dm:s Appeal Board (ANCAB). 2.Anot'be:r act:::i.oo.filed by the Qlic..lc;lloon UatiV'e Corporat:ion is a civil suit:filed i.n U.s.Dist::"'.....d:Ccu:1:(cas efile rro:rber A-80-207).Th.:f.s cou.rt sui!:~filed.on village deficienq l.mds ~enc.cmpass the. em:1:re project:a:res..1b..ere a:re also l.ands ~t±dn this a:rea that: have been seleet:ad bv t::e State of Alaska and c:nu:.Mr.Dennis E!cpeell of the U.S:DepaJ:t:m:at:cf Im:e.r....or Reg:!..ona.l Solicitor r s Qfft ce is the At::r:J::rt:!:Js on the abc.rve case for the !Je?art:cent:of Im::.ed..cr.!he c:f.:vll ccm::1:<:3Se ~be a consid.erat:1on in the grandngaf ar:I'f rigb.t:-<Jf-ways by the Cepa:cCIeUt of Inr:a...-:ior fer access t::l:1 t::he ~jeet':.t.hile the ~my gram:rlgh1:-of-~ pel:mit:s on Lu1ds under lit::1gat::ia1.t±le standa:rd !Je?art:cent:pracd..ce ..... ..... ..... 2 ~1l:Ces ncc:ificaci....~of the olai.nci£f CCri.ck.alccn)a£r~~o1:0'00sed i.ssu;mce of ~...ghc-C£~.~practice all.cw'13 t!:'.e pl..a..ll1r:ff co file for a re.:rt:=ai,...irg orde:=::bar:;.;auld seep c-.eissuanc:e.at t±'...e rigtu:-of -r,.;:a;y-.~=ecemre"'.d tb.a.t:the APA ~s coo;gar:e.f-=:b.er • ·.....it±. the 5D!and t:b.e Regi.cna1.Solici.ter's Offics,tte qt:eSct.or'-s a£lar'..d and litigation 3 t::3.OJS _ 3.The end.--e a:r:e.a,'rit:b.i.n.t:he Cock Inlet:.agreerent b.otJnda:r:r is 1aDd cccside.red en as Appe::dix A lands. !be secood COI:l.Cept:'O:e '~d li..1<e to d:!.sc..:ss is tb.e pioneer read as proposed by Ac=es .:1.!I2.ri.can duri....cg the O~...ober ZOt::l brief':~g t:hi.s year.As·..e u::lCe-..-st:aod the sitw:t:i.on,for t±.cse rcur:es :±lat:origi nate eit:ber on the Ce!-.ali E.i..gt-',.;c:ry. A.l.aska RaiL"'"'Oad;or the Pa-.-ks Higfr'..;ay.oe P'f....oneer Read.·..oild have to be ccostt"~-ed dm:ing tbe.ye.m:3 1983-1984-itt orC.er to ar=::i~at:Umrcv'ed a..ccess <iI::::r...:og 1985 aod early"1986,~"iCUld t±.e.tJ.provide fer a st:a.t:e"of cont:iDous access frcm t:be middle erE 1986 ~.The 'Picoeer Road.conc.e!)t:reaui.=es road r"...gb.t-d-r.o:a:y .md re1at::ed pe::::rit:3 dIJ:::"i...r::g the yesr or 1982-;.;Qi"d:J.is "f':::i..a= to r:--e FER!:Jicens.iDg process.'!he:::a are.cbvioosly s~al prcble!:3 •..i.th t:b.e ~onee?'Road ~t_,A&-;.;e ~~t:md tbe sitcat:icn"tb.ese are.sar:e of t:he prcb 1.e::s •.. 1.Ea:rly c:r:cs~-enc:E::he Picr..eer Rc...sd ·~d have to be pe:::::I!ir:-~by a.BIM.:igi:lt:~~~o'~d.reqai....-e an eavL~O'IE!ltal.~~ st:atf'lTl!rn:separate fran.t±ose ciocr:m!.."ltS o::w -:e,;"'g prepared for the overall Susi'T8 p=o jed:.ApproadJing the ?"~..eer'Road P:=o j f!C!:in a. sepuat:e ITS ...i.tb.ct:::t:evaluat:i.:.'1g it'p em::1=e.Susio::a ?=ojec=rra:'f 1ea.ci 1:0 a.legal 0811 enge of piecerm.aJing a.bi..g:ger projec=.In adler r,.;ord.s-,-;,;e'could be c::.a..lJ..e:Dged tbat,the road is ~el7 a.parr:of a. 1.aI:;e:r ~~~....c proj ec::-ro.dJ.shculd "be aoaly---ed at:crl2 t:ia:e. Z.The Piooeer Road ""'O'..l1d devi..a.!:e.f=o::n tb.e locat:ion c£t..'"'..e fi::.al access road pa:r=::C:1J arly en d:le rotI%:esout::::l o£t±le SUSir--8 Ri.\I~be!:"~ Dev1l'g C:mjon and t..1.e ~QZnS.31::e. 3.'!he P'4....oneer Road coccept:requires dec.i.si.co.tmlC.I::g by the Cook L."1l.et: Native Ca:axJ:cat::icn.State of Alaska.and the Bureau of Land Ma,oage- IIEDX:..pr...ar to the 1.(c ......sing by FERC."..;e are cooco~.i ~at:a. deci.sioo.CD.t:he pj oceer ,Road rrB:']lead to envi.~~t:a.l and eccnan:ic CODSeqoences pI:Lor to t±e aet:oal 1j'"'<'T.s:L."1g of.t..~~ject.T.Jrlle it: :U 001:W<.ely a EERC U cense will Ce denied ai~er the fe.:1Sibility of dJe project:has been est:abllsh.ed,t::1.Ire has a -..:rr of charging the values set:by tJItttY of ear past:eec::LsiDns and .~c.:mcoc:take d:le Pioneer'Read ccccept:llgtltly.'There are three oOer ~ec=s cf the P1aoee:r Road concent:,.;e shcu1d mend.on.'Ihose are:1)it:is.Vf!X1 lilaaly a Sed:!.on io pe:tmi.t:.will be reqc:i.Ied fer crossing n.avigab le ~t:e::s(Susi.tl:aRiver)J 2)a Secticn 4i)4 pe~t:for ·.;;er 1 -m d s will be requi.:rerl f:rcn t::b.e Corps of Engineers,and 3)r+.e d.ec.i.sion on the Piaoee:r Read coc.cept:~l likely Ce elevated tot.b.e level of the 3 Sec=et:ary cf ce I:lte..~or"All GI:t..":C afcrc!!".e..o-:.r';rr:cd prcb len areas take t::.::e and.as t::.=e is of t..~essence.i.t i..s e..t_ena1:r i.m;or-<2Dt that:if a.:rot.tt:e is C=CSe!l C::lat re-::ru.i=ed ~-'-'"'!leer :toad e=X".oS t=ue=i.cn i'"-e decisicn be made.as e:rrl"'T as oossible <md r:..LuLt :..~aoolic:.a::::icn for r-mt:-o.i~aI:.d o~::.e-..-:m.t.i be :raCe C.j r:.~e ~a.rt:::ED.t:at the Int.e:::"'....m:and DePa-~cf ~rec3e agQ?"c-i es at:,7-<P earliest.possible TTX'lTI!T'r. TIle tb.i......-o..m.jor S"oJbjed:brought:~car ac:--....ent:iDn is en?i :::crmenral ~-3.As agepd es:~,.;e are all c.::cm::e::-....ed abaar:the rela.d..ve.en- vi.:J.:t4 Ii em-a 1 t:r'cJ:feaffs that:n:ust:be made i£tb..is proj e~is to be com~.~c:mcoc,~.at:thi..s t:iJIe.::e!":::mrer:d to 'j'CU a. prefer.:ed access route aod !ICde.~e are cbviausly sa:oe rcu1:.SS that::pest:rela.t:ivel.y b i gber e.tlVi.:rormental c.os t:3 •Those routes are, the cce sour:b.of the Susitca.Ri.ve:::'be~Devil'3 Canyon and lo4ar;ma,aDd second]y.a.si.gcif:ic.aI::t area of envi:::::am puca I cooeern is ,~ the.cor.z:-4..dm:pa.:ralJeUng the.rod;an River.Also.a.sigoific.ant e.a:v:L."""C!J'TP!'!t3 r .ccr:eem is posed by !:be rcur:e sou:r::b.f::cm the Dena J i 8"i~•'!he iJT¥Rd:b.e:re is scmerNhat:mic.gated by t±.e.~ste:!.':l rcu%:e Do;J orefe::=ed as coccsed to t:e.route ..r..,a.3t:tt:::e I..a.ke.It:is sd.ll nne1 ear as to the tis 1 at:i"'re.megr;i r-,Oe c:E ~e ~a.ct:en c:ari-bou.posed. by ti':Ie ~:Iro%:e som±t.f:::"c:m t:b.e Dena 1"l 'po';giY.::a.y.T..J:rl.le '..;II!.a:re great:ly cmCP'f'tJed a.bout:the ~t:ctt t±::.at:~..1x:u.b.ed.-..;e,feco-l t±:l:at:t:b.e env:u:O'elM!!31 r=aCeoff.in qc.esc..en is cae af ~!:S en r:±le c~....:bou b.e:rd ~tbe impa.~...s af !ICre prodo.ct:i".re habi::at:3 in.t.be a:rea.of rpdfm River at'Fog Lak.e;g.Frtm an envUocnenc.al st:.atld- poitlr7"the n:x1t.a 30ncer1y f:.tJ:LOe OEma Ii F..i.g!T-:.)'See'!lS prefe.::...able ,-,em .t.ne aspecr of·minimf .....ng di.s~'jTlce af £h....duc::::..7e r-;1bit:at:. The 1:OUX:e frtm dle Dena 1 j...~.:;ases a.sec::r'..cia:l:y impact:.tba.c of hr:,man ~&to :::be:p:rojeC!:dre.a a:f,~c::mst::::'l.:l:t:i.cn.Public access to tbe proj e~are.s.is a t"'...",o-e""....ged S'to."01::i.~:-ee.....--gDize tbat the ~~.Projec:my provide'a "':a1uable ~.SOttrC2 for ,- ...,.,.....,..,1",-....-.._.....L._~_,Al .....l -,--is also ~~.P<n 1-__,ro-R":"'_:-__~_...:~_l"';;-a.L,..~l'\QJ..•..L..---0-----,l...u..,,~vt::.;r: tbat:public rec:eat:1..oo can be a.dest::".JCt:i~acti...,ir::r.We submit r:::hal:c::cm:::'Ol of t:±1a a.cr.:::esB,tt..e St::&te G.:m!I,.;n.;s.,u::d :.~iJrojec:: mmsg~a.ft:er const:rncdcn,~tools eMf:cun be.U!1ed to ~ tb.e ~e effed:3 af i.t:u:::re.ased rec=eat:ion cooort:L"nit::i.es.'!be .qcest'1al cf pcbl.ic.a.c:cess·to the.project:area is·a spinoff af tb.e. type of acr:ess·t:b.ar.u devel.oped fo'!:project:COOSt::uct::.on.~e mmy problam.are pt'e5em:~submit:.to ]OU the fallC".wing c::o.clu- s:i.ccs:. a.-Both rail .m,d road a.cce.ss ~l be reqa:L..-ecf for ccoso:-.JCt:ion. ~feel tb:f.:J concept:provides a.deqt:a~fle::dbi'';q aDd 10g:i:3- t:1c:r ·dnri ng c:ocst:rt:et:1a:l phases. b.It is ~bab1e the State of Alask:a C3%l c.onst::uer a project:of tb:is-magni t:ede wi.tbcut·Sc.:rD!fcmn of =ead.Uy ~Ie pub lie. access as a residual product. c.'Ihe.ent:iJ:e Susi.Qa proj ect:is su:r=ot:.o."'1ded by pr....ma.r...J."1 t".-o ld..Dds of 1.and ~F ~ely 215 t 000 ac=es c:f private 1.aI:ld<J - ..... 4 in Nad."\~~rups.ar..d a 'lPry large ac=eage C£St3.ta l..and. The Cock !clec Region Co-rporac:.on has L.~C3.t2d t~ey p=e£er deve..lcpm!IIC of t:he.i=l.ands as a ;:;:eans cf 6er~at:i.o..g =e~.J'el::'!Ue_ we can dednco tb.a.c the State cf Alaska like..n.se is c:::n:mi.::ted to the develcpue:c:ef.the hi ghesc and best:cse o£it:3 ~_!b..is laDd.e--ne:rship par---em.and the re.specti.ve ~philo- scphi.es-lead·ODe to bel.f.e.;.e tb.a:t:rcad access ~l be ~ed by d:lesa CoiIO:ve:rr iJ:;xJrt:::ant:~in the azea.of tb.e projed:. The 1993 t:::Um fr~·Fm-~-<X1-l!.:c.e desdllie.has been a~y CCtlt:roVer:!i.aJ. subje<::aIJd it is cot:~uc.cierstood h.cwt:hi:l -.;as e.~J1:abllih.ed.~~d appreciaa c.lar'...Bcadon of Oe jusMficat:ion for esabl.ish.i.Dg 1993 as a p 1ann;ng abj ec:::i'l1e •/ It:is hoped t:ba:t th:is lec-..e:r cl..a:1:"f...:fies PL"i'3 posi H en en land sc.CJs,EIS,and RCW'gL?lf!-ing,£i:.t{c:~.met CtXlIOdf;mrdm...Sbculd ]OlL~fu:r:::b.e=quest::l..aos c:bat: =equL""'e e1.a.bora:d.aI.aDd elucidad..cn.feel :E=ee to c:ccr.a.ct.lIJ!• / j ! ,.POUCH 0 -JUNEAU 99'" ·-,.- ,".,!,...-..llI ij ill~ :j i1 iJ-I.,:)I DEPT.OF ENVIRON~IENT."-LCONSERVATION (907)465-2600 ! ! i. .LA Y S.HAMMOND,GOVERNOR Mr.Charles Conway Chairman,Board of Directors The Alaska Power Authority 821 N Street,Suite 201 Anchorage,AK 99501 Dear Mr.Conway: April 21,1982 Subject:Decisions on the Proposed Susitna River Hydroelectric Project As we are all aware by now,a decision on further work on the proposed Susitna hydroelectric project will not be an easy one, especiaily considering the legal constraints we are under.There are a number of alternatives which the Authority should consider, not only those recommended by Executive Director Eric Yould,but several intermediate ones.In order to understand this situation better,I would ~ike to share with you my ideas on several of the factors we are required to consider when making our decisions: A.Economic feasibility and financial considerations.The Acres feasibility study and the Battelle Susitna alternative study determine economic feasibility using different mechanisms. Acres derives a "net economic benefit"formula which derives a present worth for the difference between the cost of the Susitna project over its projected economic life and the cost of the "best thermal alternative."Battelle derives a "levelized cost of power"which demonstrates the per killowatt-hour costs of several alternatives,one of which is Susitna.Although both studies predict that the Susitna project is "feasible,"in that it presents a positive "net economic benefit"and a lower "levelized cost of power,"the actual figures are quite close to those of the thermal alternatives,and are quite sensitive to a number of exogenous factors such as demand rates,cost of fossil fuel,discount rates,cost of borrowed money,inflation,cost escalation,and unknown technical factors.Further,the differen- tial in costs between Susitna and its alternatives may be less than the inherent error in the calculations. Acres indicates in its analysis that the Susitna project will suffer an "inflationary financing deficit"for at least the first Mr.Charles Conway 2 April 21,1982 .... .... .... .... .... .... twelve years of its existence.This factor res~ts in a projected production cost of the Susitna project of 30 cents per kilowatt- hour and of the base case thermal plan of 14 cents per kilowatt- hour.The "inflationary financing deficit"would begin to be repaid after the first twelve years of life of the Susitna project,but Acres does not speculate as to when it would be "zeroed out."Acres goes on to recommend that the State essen- tially pay for the "inflationary financing deficit"in advance so that the project can be "competitive"with the base case thermal option--that is,that it will generate power at,or cheaper than, thermally generated power.This analysis is sensitive to the same factors as the "net economic lJenefit"analysis--the thermal option costs are especially sensitive to price escalation of fuel. AJ.so,Acres compares a subsidized Susitna project with an unsub- sidized base case.It would be of value to see the projected energy costs from a variety of equally-subsidized comparisons of Susitna and the base case • All this indicates that the economic feasibility of the Susitna project has not been demonstrated,at least to my satisfaction. Of equal"concern are the financial considerations.In a very real sense,Susitna's financing is tied to the price of crude oil. If the price of crude oil is high,Susitna looks inviting when compared to the base case thermal option,and the State may have the oil revenues to provide the front-end subsidy Acres recom- mends,albeit not without sacrificing other capital projects. At present,however,the real price of crude oil is low,thermal generation may be more economically efficient than Susitna,and the State treasury cannot fund the "inflationary financing deficit"without severe sacrifice to the State's general fund budget.Also,revenue bond interest rates are so high as to potentially adversely affect the economic feasibility of this project. Under the economic and financial analysis performed by Acres, the "net economic benefit"of the Susitna project does not inure to the Alaska Power Authority or the State treasury,it goes to individual ratepayers.In view of the fact that current legisla- tion requires neither a repayment nor a rate of return on the . State's cash investment in this project,regardless of the size of that "benefit,"the State treasury wi.ll actually lose its investment in the power project,andt the long-term opportunity costs associated wi.th that loss. The alternative to "partial,_or .total,State financing of the Susitna project is to use revenue bonds;with perhaps some form of guarantee by the State,or some other form of bonding.If, however,the project were to be required to repay the entire costs,including in~er~st,.of the project,the "inflationary financing deficitn'<may result in early-year costs of,power which~:...'.>~...... •.__•._----------------------- Mr.Charles Conway 3 April 21,1982 are twice those of the base case.It would be necessary,under this scenario,to require participating utilities to purchase power from the project on a "take or pay"basis where each utility must guarantee it will either purchase a minimum amount of power at the project's cost,or pay the equivalent amount to the project if it doesn't need that power.In this way,the Authority can assure it will recover sufficient revenues to pay the bond payments.The willingness of the pertinent utilities to enter into such agreements,knowing they may be able to generate I less expensive power at least in the early years,is speculative. B.Environmental and technical considerations.It woultl appear that,by and large,the Acres feasibility study adequately addresses most of the technical aspects of engineering design and construction.It also would appear that,with the possible exception of relict river channels,that sufficient information has been generated from field investigations to begin detailed design.It may be that new field information needs will emerge over the next few years of work on the project.However,it is not likely that this would result in sufficiently radical design changes to increase the project cost substantially. On the other hand,there appears to be substantial question on the amount and quality of environmental information and the type and extent of mitigating measures,if any,that would be associated with this project.Virtually all federal and State resource agencies were critical of the level of information gathered to date,and several suggested that·at least an addi- tional year of data is required to understand the biological populations and physical environment.Further analysis was also indicated for an adequate understanding of the effects of this project on the living resources and other environmental factors. The mitigating measures incorporated into this proposed project have a direct bearing on its costs and economic feasibility.In my view,both the capital and operating costs of the mitigating measures,be they fish hatcheries or other means,is a legitimate project cost and should not be left to the whims of the Legisla- ture's appropriation process.It is not certain to what extent these measures were incorporated into the Acres and Ebasco cost estimates of this project.However,of even more importance is the impact of controlled flows on fisheries,and the in-stream flow needs of the resident aquatic populations.If the Susitna River discharge is managed to protect fishery habitat,a concomi- tant decrease in potential power generation may result.At present,there is no agreement between the staff of the Power Authority and the resource agencies on what the stream flow should be,however,a substantial deviation from the Acres optimal needs may result in the project becoming economically infeasible. Mr.Charles Conway 4 April 21,1982 ..- -- .... - -- - C.Alternatives to Susitna.I don'tthink anyone would be surprised by a characterization of the Battelle study as "disappointing.II Although Battelle did review ~ome traditional sources of electric power which might be alternatives to the Susitna project,but did not review in depth some options which, in my opinion,seem viable and quite possibly economically com- petitive with Susitna.In addition,Battelle did not review possible non-cost means of sUbsidizing public power in the rail- belt area.Further,Battelle apparently considered at least some options as having substantial environmental objections which,at least in my opinion,are not all justified.Battelle did not adequately treat the options of using gas to generate power at Prudhoe·Bay and transmitting it to Fairbanks and Anchorage,or of building a gas pipeline,independent of ANGTS,t~Fairbanks and Anchorage,and using gas for home heating and electrical generation of the railbelt.Battelle did not thoroughly consider. using Healy coal to fire a series of 200mw steam-electric power plants.The coal option was apparently criticized as causing air pollution problems and contributing to the "greenhouse effect" and "acid rain."Although the increase in ambient atmospheric G0 2isnottobescoffedat,the contribution of six 200mw coal-fired plants to ambient C02 is probably negligible.As to local air pollution,that depends substantially on the location of the" plants,but considering the type of coal involved and the type of technology available today,it is not likely that a perceiv- able Lmpact on visibility would even result from a properly designed and operated plant.In addition,the low sulfur content of the Alaska coal available would argue against a potential decrease in the pH of precipitation.. Battelle al.so did not look at the possibility of the State using its natural resources,rather than cash,to subsidize an energy project.For example,the State could dedicate a portion of its North Slope royalty natural gas to.the Alaska Power Authority at no charge:the Power Authority could then build a gas-fired power. plant and the necessary transmission lines to carry power from the North Slope to the railbelt.Likewise,the State could ' dedicate some of its coal reserves to the Authority for use in coal-fired generating plants.Although I ~sure there would be legal and technical problems associated with this approach,it is at least worthy of investigation. D.The Federal Energy Regulatory Commission license process. The Susitna project may well be one of i:he largest non-federal .. power projects ever constructed.As a result,FERCwi~~doubt- less have a larqenumber of intervenors who dbject to ·part,or all,of the State's application.I ful.l.y expect that a number of national environmental organizations,as wel~as their Alaska counterparts,will intervene in the FERC proceedings ..and contest the Susi~project as the II pork barrel"water resource project Mr.Charles Conway 5 April 21,1982 of the 80s.Their success in intervention and/or contesting the required Environmental Impact Statement will depend upon the quality of the application before the Commission,the reaction of State and federal agencies to the project,and the environmental organ1zations 1 own resources and objectives.APA and the State have no influence over the latter factor,but we do control the quality of the application,and can work directly with affected agencies to address their consensus.At pr'esent,however,the reaction of resource agencies seems to range from ignorance of the project to something akin to opposition.Most agree,however, that more information and more planning is needed before an application is submitted to FERC.Submission of an application before these concerns are completely addressed will likely cause delay in the project because of the very adversarial nature of the FERC process,and will provide substantial and effective ammunition to project opponents. The alternative of submitting a preliminary application for a FERC license has not been recently discussed by the Board.A number of witnesses suggested ~uch an action,and indicated that it might be a way of involving the federal agencies,including PERC,in the project so that the Board might know more about what would be required to submit a satisfactory,complete PERC applica- tion.In addition,the preliminary application might well cause potential intervenors to identify themselves,and their concerns discussed. E.Recommendations.Regardless of the decision by the Alaska Power Authority regarding Susitna,substantial new electric power generation facilities will be needed in the railbelt area, both to replace facilities being retired and to meet new demand. In the normal course of events,those facilities would be con- structed by the utilities involved,however,the prospect of Susitna's construction has led to a hiatus in planning by public utilities for long-term,base load needs.Further,there may be substantial economic and resource efficiencies gained by central construction of generating facilities to serve all railbelt utilities.At present,the only institution that can construct central facilities is APA.To allow utilities time to plan for their needs,it is essential that APA make a firm decision and commitment within the next 2-5 years.Because of the economic uncertainties involving the Susitna project,and their sensitivity to timing of decisions,it may not be possible to meet the needs of the utilities and also make a firm commitment on Susitna at its most opportune time. Considering all of the unknowns arising out of the Acres feasi- bility study and the Battelle report,I suggest that the Power Authority take the following action: -------~------------------~------------ Mr.Charles Conway 6 April 21,1982 r""", - (I)Defer deciding upon submission of a formal application to the Federal Energy Regulatory Commission for at least one year. (2)Investigate the possibility of filing a preliminary application and,if it is found to be to the Authority·sadvantage to do so,file such an application at the earliest opportunity. (3)Continue studies of fish and wildlife and accelerate,when possible,design of mitigating measures. (4)Continue work toward design of the project and any further associated field data collection. (S)Investigate the possibility of entering into formal memoranda of agreement with resource agencies, especially the federal agencies,so that they can be provided with a formal avenue of communications with the Authority,and the fun~s necessary t0properly evaluate this project. (6)Inaugurate a new study of alternatives so that the analysis of alternatives required by the FERC EIS process will be adequate,and so that APA and the State can be assured of selection of that alternative which is optimal in economic efficiency, environmental,socio-cultural impacts,and other relevant factors.This study may be conducted by others,but it should be understood that the funda- mental responsibility for its adequacy lies with the Authority. (7)Recommend to the Governor that he formally designate,through an administrative order,an organization representinq the affected State agencies, to work directly with the APA Board and staff.This group would help assure that the consensus of these agencies are addressed in some organized manner,rather than being revealed in the FERC intervenor process,as was suggested by the Department of Natural Resources. Of course,all of the above is predicated upon the Authority receiving sufficient funding from the 1982 Session of the Legis- lature.Although that is,at this point,yet unknown,I have every confidencetbat our Susitna budget request will be honored. Mr.Charles Conway 7 April 21,1982 I would be pleased to discuss these proposals in detail at the Board of Directors'meeting April 22,and trust the Board will award them every considerati~o~~ Vice cc:APA Board Members Sue Greene,Office of the Governor APPENDIX El1G CORRESPONDENCE RELATING TO ADDITIONAL STUDIES AND PROJECT REfiNEMENT f"""'. - ..... r-, APPENDIX 11.G ADDITIONAL STUDIES AND PROJECT REFIN£llilENT In response to agency concerns and in recognition that further studies, especially in the area of fisheries,were warranted pripr to submitting a FERC license appli~ation,the decision was made by t~e Alaska Power Authority to delay the license application date.Studies and project refinements that received agency review included thewildlife/habitat issue,water quality and flow modeling,access plans,and downstream flow release schedule.Agency consultation took the form of Steering Committee meetings,modeling workshop, Fish and Wildlife Mitigation Review Group meetings,and request for written comment on the revised access plan.Correspondence,minutes of meetings, and meeting schedules are contained in the following pages. Correspondence is presented primarily in chronological order.However,in some cases,a response to a letter directly follows the letter to facilitate an understanding of the flow of communication.This results in an interruption in the chrono log i ca 1 sequence. Dear Ms.MCAnerney: ,~ .... Febru~ry 25.1932 P5700 .11.92 T.1533 Ms.lee McAnerney Department of Community and P.egfonal Affairs Pouch B Juneau.Alaska 98111 Susftna Hydroelectric Project Agency Coordination Meetings .'\s an agency representative of the t1istorfcal and Archeological Group reviewing the Susftna Hydroelectric Project you are invited to a meeting on the morning of ~arch15,1982 in the offices of Acres ~~erfcan Inc •• 1577 "C n Street,Suite 305.Anchorage.Alaska.Tne purpose of this meeting will be to review the results of the Phase I archeological studies,assess mftigation options and discuss future study programs. If you have any questions relating to these meetings,please contact ~~r.Vern Smith of Acres,at (907)276-4333. Sincerely, KRY/1jr John D.lawrence Project r·1anager ~e~ru~ry 25.lSc2 P570:J.l1.50 T.1537 f~r.Roy Huhndorf Pre:i1dcnt Cook Inlet Re~1on.Incorporated P.O.r,rawer 4F: ~nchorage.Alaska 99509 Dear Mr.Huhndorf:Susftna Hydroelectrfc Project A1ency Coordination ~eetfn9s As a member of the Aesthetics and land Use Group reviewing the Sus1tna ~y~roelcctr1c Project you are inv1te~to a m~eting on the afternoon of ~~arch 15.1932 fn th~offices of Acres Amerfcan Inc.~1577 "C"Street. Suite 305,Anchorage,Alaska.The purpose of thf5 n~eting will be to discuss the results of the Phase I studies and to review the altgrnatfve and proposed recreation plans. If you have any questions relating to these ~eetfn;s,please contact Hr.Vern Smith of Acres at (907)276-4388. Sincerely. KRY/ljr John D.lawrence Project ~~anager F~h~uary 25,!q~2 PS700.11.71 T .1537 Mr.Keith Schreiner r.cgfonal Director.Region 7 !J .5.r1sh Jnd tHl dli fe Service 1011 E.TUdor !toad Anchorage.Alaska 99503 Dear r.r.Schreiner:Susitna Hydroelectric Project Agency Coordination ~eet1nQs ,'3 a mt!M~cr of th!A~tth~tics/land Use an1 ?~cr~at1o!'1CroIJps raY'f~"1ng the $L1Sftlla 4ydroele~trfc ?roject you are invited to a m'!!etfn~or:th~afternoon 07 :-tarch 15.1932 in the offices of Acres I'm~rican Inc.J 1577 "C If Street. Suit~305 •.~nchora~e.l!\laska.The purpose of this meeting \int be to discuss tr.e results of the Phase I sttJ~fes and to review th~alternative and pro- posed recreation plans. If you hl!Ve any questions relatfncr to these meetings,please contact "r.'fer:1 Smith of .t\cres at (907)276-4,988. Sincerely. - KRY Iljr John n.LaHrence rroject r.unager February 25,1982 P5700.11.92 T .1531 Mr.Ronald O.Skoog Commissioner State of Alaska ' Department of Fish and Game Subport Building Juneau,Alaska 99801 Dear Mr.Skoog:Susftna Hydroelectric Project Agency Coordination Meet1n9~a As an agency representative of the Historical and Archeological Group reviewing the Sus1tna Hydroelectric Project you are invited to a meeting on the morning of March 15,1982 in the offices of Acres American Inc., 1577 "C U Street,Suite 305,Anchorage,Alaska.The purpose of this meeting will be to review the results of the Phase I archeological studies,assess mitigation options and discuss future study programs. As a member of the Recreatfon and Aesthetics/land Use Groups you are also invfted to a meeting at the same locatfon on the afternoon of ~arch 15,1982 to discuss the results of the Phase I studies and to review the alternative and proposed recreation plans.• If you have any questions relating to these meetings,please contact Mr.Vern Smith of Acres at (907)276-4888. Sincerely, KllV/ljr cc:Mr.Thomas Trent State of Al aska Department of Fi sh and Game 2207 Spenard Road Anchorage,Alaska 99502 John D.lawrence Project ~anager ..... february 25.1982 P5700.11.92 T.1535 Mr.Robert McVey Director.Alaska Region National f".arine Fisheries Service NOM P.O.Box 1668 Juneau.Alaska 99802 Dear Mr.McVey:Susitna Hydroelectrfc Project Agency Coordination Heetings -- As a representative of the Recreation Group reviewing the Susitna Hydro- electric Project you are invited to a meeting on the afternoon of t~Zlrch 15. 19B2 in the offices of Acres American Inc ••1577 "C·Street.Suite 305. Anchorage.Alaska.The purpose of this meeting will be to discuss the results of the Phase I studies and to revie~the.alt~rnative and proposed recreation plans. If you have any questions relating to these meetings.please contact !1r.Vern Soith of Acres at (907)276-4883. Sincerely. cc:Mr.Ron Morris Director.Anchorage Field Office National Marine Fisheries Service 701 II en Street Box 43 Anchora ge,Alas ka 99513 r I KRYl1jr John D.Lawrence Project Manager Mr.John E.Cook Acting Regional Director Alaska Office ~ational Park Service 5~O West Fifth Avenue Anchorage.AlasKa 99501 Dear Mr.Cook: February 25.1~82 P5700 .11.92 T.1532 Susitna Hydroel ectricProject Aqency Coordination Meetings As an agency representative of the Historical and Archeological Group revie~1ng the Sus1tna Hydroelectric Project you are invited to a meeting on the morning of March 15,1982 in the offices of Acres A~erican Inc •• 1577 '·C Il Street.Suite 305.Anchorage.Alaska.The purpose af this meeting will be to review the results of the Phase I ~rcheoloaical studies.assess miti9at1on options and discuss future study programs.- As a member of the Recreation and Aesthetics/Land Use Groups you are also invited to a meeting at the same location on the afternoon of ~4rch 15.19822 to discuss the results of the Phase I studies and to review the alternative and proposed recreation plans. If you have any questions relating to these meetings.please contact Mr.Vern Smith of Acres at (907)276-4888. Sincerely. KRYlljr CC~Mr.larry \'!right Niltional Park Service 1011 Eo Tudor Road.Suite 297 Anchora1~J Alaska 99503 John D.Lav/rence Proj ect Ha na ger - ~~i.'rch 2~lq82 ~:700.11.92 T.1534 Hr.T\'::illi:JlaneState-~istoric Preservation Officer Alaskn Depsrtpcnt of Natural Resources Division of Parks 619 Varehouse Avenue,Suite 210 Anchorage t Alaska 99501 Dear r1r.Shaw:Sus1tna Hydroe1ectrfc Project AaencyC~rdinat1on Y.~~tir.Qs As an agency representative of the Historfca1and Archeological Group reviewing the SusitnaHyJroelectric Project you are invited to a meeting on the F:lOnling af !:~arch 15~1982 in the offices of Acres Jtrnerican Inc.t 1577 "e"Street,Suite 3a5~,!l.,nchorage;AlAska.The nurnose of this meeting ~;11 be to review the results of the ?hlise J archeolo11ca 1 stud1~s,assESS dtiqaticn option!:and discuss fut:J~study {"!roor-ll:1S. If you have any questions relating to these /7-eetincs.rlea!:~contact Mr.Vern Smith of ;lcres ~t (907)276-~:--Bn. Sincerely, John D.li1·.lr~nce Project f<l..lnalF'!r KRY:dll' cc:rr.Alail Cllr!'·on ~ivisicn of fies~!rch ;l~~elo~m~nt uG':'!Jrtnlt:nt of ;~aturJ1 R0$o:Jrc~s !'o:J'::!1 7-:}-:5 Anchorage.Alas~a ~~5~1 DIVISION OF RESEARCH &D£VELCPMENT UEP.'\.HT2HE."'-T OF ~·ATUn.-\L RE-SOURCES ,, Pouch 7~OOS ~~ ANCHORAGe.A~ASKA~995~J I / / ,I / '"'~,.... i I '"I ~ "I /,\" "I .I1:\I':'\ ....~LJ u I :,...~ 1\,•\ ~',"'-". -=J-~0 Mar~1t .s,1982 Eric Yould Execucive D~rector Al.aska Pover Authority 334 \.les I:5 r:h Avenue Anchorage,AJ.ask..a 99501 Dear lir.Yould:. In the pasl:18 Cl1otlchs,c:he Susit:n.a Hydroelectric Steering Commitl:ee (SaSC)has revieved many aspecl:S of the Susitna Hydroeleccric Feasibility Plan of Study.\.Ie have been briefed by,and have consu~ced V'it.h many of the Acres American.Inc ••contractors and subcontra~tors.On Noveober 21. 1930.the sase transmitl:ed to APA a comprehensive reviev of c:he entire Task 7 (environmencal and socio-economic)Plan of Study for the proposed Susic:na Hydroelectric Project.Dur~g the s~er of 1981.~ose of the SHSC members parcicipated La a field crip to the pro?osed dam sites and to some of che field c~ps ~here invescigacions yere ongoing. As a resulc of these and ocher Susicna Hydroelectric relat:ed meetings and discussions,c:he m~bers of the Steering Committee are probably the bese informed representatives of those agentries .mo Yi~l par,=icipate in the decision Qaking and pe=itcing p't'ocess."The SHSC az.e::1oers believe it is desirable to idencify the most important issues pr~or to che issuance of the dJ:af t feasibilic:y study for reviey and comment.iole hope this ~ill achieve three things:(1)prOVide a basis for agre~ent bet~een SHSC and the Alaska Pover Authority on che status of icportant Task i issues and concerns;(2)provide the vital information to those Qot vell informed so they can be avare vnen chey reviev che findings prOVided in th~drait feasibLlit.y study;(3)vhere appropriate,co identify pocencial remedial accions to the APA to minicize if ~ot resolve the concerns that are raised. The p't'ocess that the sasc yent through in creating this lec~er vas to request alL che SHSC Qe~bers c:o compile a lise of issues and concerns that merited actencion of the APA.This list yas then drafted.re- vieved.and approved by the SHSC members. !he issues identified belov have been placed in t~o cacegories.The first encit~ed "Overall Study Approach"deals Yith those issues and concerns vhich transcend specific studies.!bese concerns are Qot entirely in the scope of che feasibility study contract or necessarily the sale responsibility of the royer Auchoricy.Hoyever.c:he decisions the APA and Legislature may make vith respect to the Susitna project in c:he next 60 days could obviace chese concerns.!be other cacegory is entitled "s tudy Specific Issues"and is self-explanacory. - E:ic Yauld 2 M.arch S,1982 .-, - The following are che overall scudy approach probleos ideneiiied: OVERALL S111DY APPROACH 1.The mose urgenc and mosc imporcanc issue is ehe re.laeionship bec·Jeen che ciming of findings from studies conducted by Acres American and ics subcontractors and ~heo che Stace of Alaska will decide ~hecher co build Susicna.The problem is chat existing lay may resule in a decision by che state as co ;;hether che dams should be builc before che socio- economic and environmental coses,impacts,and crade-ofis are kno~. Alehough che March 15,1982,Susitna Hydroelectric Feasibility Scudy ~ay assisc in deeermining if ehe dams can be builc in a narro~technical (engineer~g and conscructabilicy)sense,it cannoe speak eo significant public policy questions such as: a.is it in the best interests of Alaskans to use their money to build che dams? b.vhae are che environceneal and socia-economic 1Qpacts and trade-ofis thae have to be made if ie is decided co build the dans? In dete~ining ans~ers to such questions,there are accepeed me~hods uhich should be rigorously applied.No one uould consider building the Susicna dams ~ithout anyering all questiOns about soils stability and earr.hquake hazards.The same level of assured kno't.:ledge needs to be acquired co ansver quescions about environmental and sacio-econo~c efieccs of che dams. this issue may be oucside che scope of the Acres concract and che sale purvieY of the Po~er Auchority.A combined effort of the Poyer Auchoricy and the Governor's Office may be needed to comprenensively frame che issue and devise methods to deal ~ich them. 2.There appears to be a lack of necessary coordination betveen che various scudy casks.Unless ex~raordinary correccive efforts are made, ic is unlikely chat an integraced,relevan~,and complete environQencal assessment ~hich is acceptable co s~ate and federal agencies and to che Federal Energy Regulaeory Commission (FaC)uill be produced •.This need uas identified early by the sasc.The Nove:ber 21,1980,revieyof the Plan of Scudy says:"The Steering COlllll:l.iccee me::o.oers believe che 'l1ose co~pelling need is for a ~ell conceived process co ~pro~e the linkage and coordinacian of che various scudies."As an example of this,! :eier you to point number 1 belo~. The follo~ing are scudies specific issues: SPECIFIC ISSUES 1.A coherent an,d coordinaced Fish and Wildlife ~cigacicn policy and plan needs to be escablished iJ::lIediately.It is our underscandi:tg that, unlike the ~ildlife micigation o1'cions,the fisher-ies :nicigatiot:opcions Eri.c Yould J March 5,1982 and the overall Susitna Hydroeleccric Projece fish and vildliie citiga- tion policy have yee co produce an agreed U?OO produce.The follo~ng issues still require resolution:agreement on mitigation policy,agree- men~on the roles definition of the APA,the agencies ~th fish and yildlife authority and ~~ertise,~he Federal £nergy Regulatory Com- mission (F~~C).and those agencies vich land and yater management authority.Until these issues have been resolved,determination of the full costs and impactS of the proposed Susit~a Hydroelectric project are not possible.Failure to settle these issues Yill dramatically increase the probab~ty of delay in action by the FERC,unnecessary con£ronta~ion be~een the APA and government maoagemen~and regulatory agencies and litigation in ~he courts.Once resolution of the identified issues occurs,the FERC application process may be the appropriace forum to resolve specific mitigation issues. 2.There is a lack of ia£orma~ion to describe the relacionship betueen various stream fl~levels and the productivity of fisheries and aquatic habitat do~stream from the proposed Devil Canyon Dam.Exhibit E of the FERC application for license requires quantification of the anticipated dovn$tream impacts. J.The fisheries studies have not been going on long enough to acquire the comprehensive data and knowledge oeedec to assess project impacts. This,coupled uith inadequate instream floY s~udies.provides for a less-than-sati.sfac'tory ansuer to questions on the impact of the proposed hydroelectric project on fishery populations. 4.~ildlife studies and yildlife mitigation appear much fur'ther developed than the fisheries issues described above.Hovever,there are issues yet to be resolved in the YildliIe area.r reter you to the February 16, 1982.letter from the Depar'tce~t of Fish and Game to Rober~Mohn of APA. It appears that additional 'l.:'ork is needed to i.dentify realistic ::ticigation ceasures for lost ~ildli£e habitat and on relating ~~ldli£e use of an area to habicat the characteristics. 5.Public revie""of the Phase I environmental reports and of most cUtigation options discussion papers is noy scheduled to occur separately from the distribution and public revieu of the draft feasibil~ty re?ort:. we do understand that the decision to delay for 90 days the application for a license cO FERC (assumL,g that that is the decision from the State of Alaska).the public and agencies yill be prOVided the.opportunity to review the detailed study results and data re?~rts for a period of 60 days before final agency comments on ehe feasibility study are due. 6.The Fairbanks-co-Anchorage Int:ertie study andt:he Susitna feasibility study should be integrated.We suggest that ehe incertie assessment be included in the Susitna feasibilit:y study review pack.age. 7.!he decision on access to the d~siees and the policies surrounding their use after construction yill be one of the mO$C significant ~pacts E=ic '{auld 4 ~arch S.1982 """ - .- of che projecc.The Yukon River co Pr~dhoe Bay ~aul Road built:in con- junction t.'i.ch che consc::uc-::'on of the Trans-Alaskan oil.pipeline is a comparable situation.l.!ere is no need to restate the cotI:l:lenCS made by the sase and their parent agencies to che A2A on this cac'Cer.Hoveve::-, it is appropriate to identify t\10 of the major issues I.li.th respec':to the access question.First,APA's need co begin construction of a.' pioneer :"oad prior to FtRC licensing 0 f the dams raises some serious public policy issues.Second,the decision as to the mode of access (rail versus convenciona.l road)Clay well be che dete:r:m.ining factor for the:e."(teot and cype of public access once construction is completed. 8.The socio-economic ~plications of the availability of 1600 megavatts of electrical p~er in the railbelt region of .Uaska need to be fully described and discussed in a public rorum.It vould appear that this amount of electrical energy could result in industrialization and socio- economic impacts on the same order of alagnicude as vQuld petrochemical development.Because r:he,Stace of Alaska is sponsori.ng this hydroelet.tric proposal,it is incumbent upon tne state CO provide and present in a public forum.iniorma~ion regarding che end use of che paver aod advan- -=.ages and disadvantages of the socia-economic i.:pact.s of chis end use. The S1iSC recotl:l!:1'ends con'sideration of an approach siJ:U~ar to cha.t tlhich tlas done for :he Do~-Shell petroch~ical proposal. The SHse vill be adVising their respec~ive parent:age~cies ot the cont:ents of th:Ls 1et'r.er in order to insure diat fOc:lal agency cocmen::s co che proposed Susitna feasibility sr.udy fully address the issues'and concerns detailed above.In order to alleviate che problems icienti'=ied above,the sase recommends the follouing~(1)The ~~A should take an interdisciplinary interagency approach in identifying ~ays to iJ:l.prove coorciina,tion of the environmental and socia-economic studies to insure that the scope of and the methodology used in the s::udies are acceptable and ger:l1ane.This approach should be funded and scaffedappropriacel.y and should have the responsibility,authority ar~independence to accomplishch.is objective.(2)The draft instream floY study plan should be updaced and made public to provide oppor~unity for agencies and other groups to par~icipate in the development of the ne'Cessary inst1"eam flov studies.(3)Comp't'ehensively evaluace all potential and secondary iJIlpac:s to fish and \o7ildlife bach above and beloy the Devil Canyon and Wat:ana Dam sites.(4)Provide public par-::icipation oppor- cuni:ies t:o:inioc the public of the feasibility sr.udy and c:.he socio- economic icpacts of this ?roject and to provide an oppor~uni::y for the publi.c to give comments and advice·to t1}e Power Authority Board of Directors before the state determines vhac course of a~tion ir.should take on this project. aecause of the nar.ure of some of w,ese sugges,cions as ...ell as.the extent: of discussion veanticipate \o7il1 be re'quired beiore A:PA and its Eric Yould 5 Marc~5,1982 concractors fully comprehend our concerns,~he SHSC is ?ce?area co ceec ~ith you,your scaff and contractors ~he~ever you visn. Sincerely. Al Carson,Chairman Susicna Hydroeleccric Steering Co~itcee cc.:SHSC Members Charles Conuay.Chairman,APA Ernesc Mueiler,Commissioner,Dept of Environmencal Conservacion Ronald Skoog.Commissioner,Dept of Fish &Game John Katz,Commissioner.Depe of Natural Resources Lee McAnerney,Co=missioner,Depe of Community &Regional Affairs Cureis ~eVee,State Director.Bureau of Land Manage~ent Robere Hevey,Regional Direccor.Naeional Marine Fisheries Keith 11.Schreiner.Regional Director,US Fish &~ildliie Se~,ice Reed Scoops,Director,Division of Research &Developme~t s.Leopold Quentin Edson,FERC Mr.Robert Shaw State Historic Preservation Off1ce~ State of Alaska Department of Natural Resources Division of Parks 619 Warehouse Avenue Arachorage,AK 99501 Dear Mr.Shaw: May 4.1981 P5700.11.74 .T.868 Sus1tna ~roelectr1c Project Cultural Resources Investiqation ,""" In response to your request during our'meeting of April 7,1981.I am forwarding a copy of the Susitna Procedures Manual for the Cultural Resources Investigations.In addition,I have enclosed a copy of the Cultural Resources section from our Plan of Study. I trust this will aid in your continued review of our program.Any specific questions on this component of our study should be referred to Mr.lewis M.Cutler of Terrestrial Environmental Specialists,RDBox 388, Phoenix,NY 14135. Yours truly, KeJrin Young Environmental Coordinator KY:adh Enclosures MEMORANDUM.:..~ DEPART~OF NATURAL RESOURCES. ro: ERIC YOULD Executive Director Alaska.Pover Author!ty State of Alaska DIVISION OF RESEARCH AND DEVELOPMEaT DATE: October 11,1982 FilE NO: FROM:J::t:: Director TELEPHONE NO: 216-2653 SUBJECT: Proposed Suaitna Ib"dro Proj ect The Departaent -of BatUral Resources appreciates the opportunity to comment on pmJ'ect impacts on the proposed Susitna H,ydropoverProJect and to l'econmend JlI1tigation strategies.The depart=ent baa cooperated lIith Alaska PoverAuthorlty (APA)on tbis proposed proJect during the last tva years and ret'ers the APA to earlier comments,specifieal.ly ORR's testll:lOny on April 16,1982,to APA 'e Board.of Directors (attached).The issues listed in OUR's testimony,vater appropriations"1nstream fl.oV reservations,and access to the project,continue to be maJor concerns.Additional conrrents are listed belove In SOI:lle cases coccents 12\f repea.t earlier DIm collllXlents. As you are B.V'tIre..the department is nov 10 the process of preparing a. regional land use plan 1n cooperation vith the Ma:tanuska-8usitna.Borough vhich 1neludes the Jands surrounding the hydro project.This plan""'hicb "'ill beeoa:;pleted in 1983,nU resu1.t in land use designations and land management policies tor state and borough lands throughout the area. To date,the p.1.a.nning team responsible tor deTeloping this land use plAn has conseious:b'avoided aqy direct inTOlveDeDt in Sus1tna Hydro issues,relying. instead on the m:>re detailed york being done by other individuals vithin DR and DF'G.The planning process is nov at a point vhere it makes J:IOresense that there be closercoordiDAt~on bet"'eel1 the tvo proj ects.specirically in the t",o areas outlined bel.ov. 1)The plani:ling team can renew and comment on information regarding regional,indirect impacts of the plan (e.g.popUlation growth. changes in re6,ource deJ:lal1d,etc.). i 2)The pl.a.a can be used ns a tool to guide use of public l.s.nds to tnltigate or control.secondary impacts of the proposed project. I suggest that you designate a sta~~per~on to coordinate these tvo projects ",1th Chr1s Beck (Sus:l.tna Plan project Cl8.nager). As stated 1n DUR's recent cOl:IiIIen.ts 00 recreation planning,\Ie are concerned that recreational.facilities planned in conjunction vith the hydropover project may be under-utilized.A related concern 1-sthc high cost to the' stu.te of Jnalnta1n.1ng potentially ovel'-developed,under-used p.1blic recreation facilities. Sua1tna 1fydro Project -2-October 11,1982 - - - The 1>1 y1a1on ot Geological.and Geopb,ylSical 8urYq bu completed ..detailed reY1e11'or the ~olls e.nd geol.ogy components ot'the te....ibility study.'l'hoee COlameat.(..~te";ued)an 1ntended 'tobo 1nt'o~and to'r the cOI1aidera.t1011 ot APA and 1ts eontraetora.other geolog1cal &ad g.~lc&l concerna are listed belov. 1)Ex1at.1:ng 1nt'or_ti~ind1C&tee th&tglaclera 1n ~e proJoc.t arc& at"e re'treat1ns;this and the1r ae&aOtUl,l nature 1DII;J'atteet vater avallab111t7. 2)The two l.argo bod1....ot v&~created bY'the proPO.~project ms:y .att'cct the =1cro-cll-.t.e or the area. 3)The dame,by bloek1Dg sed1l:leDt traval,Rtq increase erosion downstream.. Ii)'!'bere ma:r be a suba1:ant1&l change 111 the area betveen the tvo da.ms oyer a periOd ot t1Jae 111 reapoa...to changes in nov ng1J::ll!,the 8.lllIOUn't ot'sediment introduced an4 traQaPorte4,and the b;ydraul.1e geometr:T at the vall.,.(gra41eat.1d.4th.depth.diacharge,and veloci~or the d1&Imel). 'rbe department request.that attf t.~f'eUe4 1D t.he project be _de e.vailable'to 'the p.1bllc aad that commercial quant1t.1es ot torest products be ..de aTa1IAbl.e to the coJllBlen:1a.1.eollll!wl1:~torbarTest &D4 ut111z:ation. At~hmenta eel Chris Beck.DRD Lella V1.6e.,Dan Al CarsOQ,DRD as.l LV 11l.D April 2,1982 Susitna Hydroelectric Project Proposal Phase II Wildlife/ Vegetation Studies Dear Ill: Enclosed for your review are ,the proposed project study plans in the disciplines of birds,furbearers,and non-game mammal s. submitted directly to the Power Authority Pha?e II Susitna Hydroelectric vegetation,vegetation/habitat, Studies for big game will be by AOF&G. The enclosed study plans,as well as the big game study plans,were devel- oped based on Phase I study results,input from the Fish and Wildlife Miti- gation Review Group on March 10,1982,and the discussions of the Wildlife Core Group on March 11 -12,1982.Please review these studies to determine if they accurately reflect the results of our meetings.Please note bird and small mammal studies in the Upper Basin have been added. Because of the necessity to begin spring studies,please review these items as soon as possible and notify me in writing of your agreement or of any discrepancies.These study plans will then be forwarded to the Power Authority for their consideration.Thank you. Sincerely, Michael Grubb Senior Scientist MG:jk Enclosures cc:Ed Reed E.Yould 1;.,!'"'",/J-f Preceeding Letter Sent To: ,... ..... ,.,.. Dr.A.W.F.Banfield Rangifer Associates,Ltd. 37 Yates Street St.Catherines,Ontario L2R 5R3 Canada Dr.Richard Taber 2024 23rd Avenue,East Seattle,WA 98112 Dr.Philip Gipson Alaska Cooperative Wildlife Research Unit 209 Fairbanks Building University of Alaska Fairbanks,AK 99701 Dr.Jay McKendrick Agriculatural Experiment Station Box AE Palmer,AK 99645 Dr.Brina Kessel Box 80211 College,AK 99708 Mr.Karl Schneider Division of Game Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 DEPART1UENT OF FISII AND GAltlE JA r s.HAMMOND.GOVERNOR 333 RASPBERRY ROAD ANCHORAGE.ALASKA 99502 April 27,1982 Michael Grubb The Liberty Bank Bldg., Main at Court Buffalo,New York 14202 Dear Mike; We had an informal meeting in Juneau to discuss the best approach for a habitat based analysis of the effects of the Susitna Hydroelectric Project on big game.In addition to members of my staff,the meeting was attended by Drs.Richard Taber and Ken Raedeke from the University of Washington and Wayne Reglin,who recently transferred from USFWS to ADF&G.Jay McKendrick attended the first part of the meeting. My main objective for the meeting was to identify major components of a study approach for budgeting purposes.I feel we need to give the Alaska Power Authority a ball park estimate of cost as soon as possible,even though details of design will have to be worked out later. Everyone would like some quantification of the "value"of lost habitat. This would facilitate measurement of impacts and comparisons of mitigation options.Most of us associated with big game studies favor expressing value in terms of carrying capacity rather than some sort of arbitrary index.We can design a system to produce either,but both are attempts to express complicated dynamic processes in simple static terms.There is a very real danger that we may oversimplify things to the point where serious errors in judgement will be made.We should not waste time and money on a study approach that will yield results we can't trust. We used Dr.Taber's Toward ~Program of Habitat Analysis as a basis of our discussion.This program focuses on cow moose in the upstream area during late winter and spring.This approach has considerable merit as it focuses on critical time periods and segments of the population.How- ever,there are some basic prOblems that may limit the effectiveness of this and other similar approaches. We believe that the proposed impoundment areas maybe critical for moose for only a few weeks each year and environmental conditions may greatly influence the area's importance from year to year.Even if we obtain Michael Grubb (2)April 27,1982 .- .... !•••, - accurate estimates of forage production ~e ~ill have trouble interpreting the data.If ~e estimate 1000 moose days of forage we need to know if it is used by 10 mODse for 100 days or 100 moose for 10 days.The latter situation would be quite difficult to accurately assess.In spring,timing of availabilty might be mDre important than quantity produced.During severe winters availability might be more a function of snDW depths than bro~se production. Dr.Taber's and similar approaches are likely to underestimate the value of the habitat to be lost unless the actual conditions we wish to evalu- ate occur during the study and the intensity of sampling is adequate to quantitatively measure habitat selectivity at that time. We.concluded that our knowledge of the mechanisms determining mDose carrying capacity in the impoundments is inadequate and it may be beyond our ability to design a study approach that will provide nice neat,yet reliable,estimates of value of habitat that will be innundated. We concluded that it is more important to gain a better understanding of the mechanisms of impact.Ho~well we can quantify them will depend on the nature of these mechanisms.Specifically we are recommending expanded studies tD determine what moose are using during late winter and spring and determine the availability of those habitat characteristics inside and outside the areas to be impacted.Phenology,particularly timing of snow melt and emergence of vegetatiDn are important CDncernS.The key question is whether higher quality food becDmes available significantly SODner in areas to be impacted,thereby imprDving a mDDse's ability to recover more co~pletely from the nutritional stress of winter befDre calving. We have not attempted to design this study but it would probably consist of determining mDose food habit£:through fecal analysis and by tracking mODse and observing plant use.Snow characteristics and emergence of plant species used by mODse would be correlated with time,elevatiDn, slDpe,aspect,vegetation type etc.We should be able to address spring use Df impoundments by bears at the same time~ This study shDuld be the primary respDnsibility Df the plant ecolDgy groups but I feel it is important that I designate an individual from the big game studies to work with the plant people tD ensure a cDDrdinated effort.I believe we shDuld plan Dn tWD field seaSDns.If Jay McKendrick can get in the field immediately he might be able to learn enough this year to design a sampling prDcedure for next year.However,it may already be to late. I fDund the plant ecolDgy plans of study difficult to evaluate because of a lack of detail.We can discuss this at our meeting during the week of May 17. Sincerely, /~, Karl Schneider Reser-reh Coordinator cc:Ed Reed -TES Jk.Gary Stackhouse U.S.Fish and Wildlife Service 1011 East Tudor Road Anchorage,AK 99503 Dear Gary: April 27,1982 P5700.11.71 T.1685 Sus'tna Hydroelectric Project .Fish arid Wl1dlife Mitigation Review Group Meeting You are invited to attend the next meeting of the Susitna Hydroelectric Fish and Wildlife Mitigation Review Group to be held at 8:30 a.m.,May 17, in Room e121 at the Federal Building,6th and C Street,Anchorage.The purpose of this meeting ~ll be to discuss the Draft Wildlife Mitigation Options Paper mailed to you on April 21,1982.Please review this document prior to this meeting. The issue of quantification of habitat loss will be discussed at a work- shop on May 18th.This workshop w111 be attended by mambers of the Susitna Hydroelectric Project Wildlife Core Group,ADF&G,and USFWS.I have asked Lenny Corin to detennine who the USFWS attendees will be and ask you to contact him for further details.The objective of the meeting on the 18th will be to reach concensus on: 1.The objectives of the habitat evaluation system we will develop. 2.A general description of the system. In keeping with past procedures,the Sus1tna Wildlife Core Group will then develop the technical specifics of the system. I am enclosing a Phase I Habitat Evaluation Report written by TES which applies a modified Konkel et al system (as discussed in the Environmental Analysis of Alternative Access Plans Report)to the impoundment and surrounding areas.I ~ll,hopefully,also forward to you before the meeting a general system developed by Dr.Taber which may be specifically applied to moose. It is mY intention to discuss these two systems,as well as HEP,at the workshop.I am asking all attendees to come with an open'mind so that we may have a constructive session and work towards the common goal of obtaining satisfactory mitigation for wildlife/vegetation impacts associated with the Susitna Project. - Mr.Ga~Stackhouse U.S.Fish and Wildlife Service I look forward to your attendance on the 17th. Sincerely. Aprfl 27 t 1982 - 2 -- -.. ..... M1cllael Grubb Senior Scientist ~m:ccv Enclosure cc:D.Wozniak -APA E.Reed -TES April 27,1982 P5700.11.71 T.1686 Mr.lenny Corin U.S.Fish and Wildlife Service 733 West Fourth Avenue Suite 101 Anchorage,AK 99501 Dear lenny:Susitna Hydroelectric Project Fish and Wildlife Mitigation Review Group Meeting You are invited to attend the next meeting of the Susitna Hydroelectric Fish and Wildlife Mitigation Review Group to be held at 8:30 a.m.,May 17th, in Room C121 at the Federal Building.6th and C Street,Anchorage.The purpose of this meeting will be to discuss the Draft Wild11feM1tigation Options Paper mailed to you on April 21.1982. The issue of quantification of habitat loss will be discussed at a \~rk­ shop on May 18th.This workshop will be attended by members of the Susitna Hydroelectric Project Wildlife Core Group,including Karl Schneider, who may bring other representatives of AOF&G with him.In order to keep the workshop size to a reasonable number,I have asked Karl to bring no more than two other people.I am inviting you to attend this workshop on the 18th and,if you desire,bring two other US~IS representatives with you.We suggest and would appreciate if Mr.Greg Konkel could attend. This meeting will be held in Room ClOg. The objectives of the meeting on the 18th will be to reach concensus on: 1.The objectives of the habitat evaluation system we will develop. 2.A general approach to developing this syttem. In keeping with past practice,the Core Group will then develop the technical specifics of the system or systems. I am enclosing a Phase I Habitat Evaluation Report written by TES which applies a modified Konkel el al system (as discussed in the Environmental Analysis of Alternative Access Plans Report)to the impoundment and surrounding areas.I will,hopefully,also forward to you before the meeting a general system developed by Dr.Taber which may be specifically applied to moose. It is my intention to discuss these two systems,as well as HEP,at the workshop.I am asking all attendees to come with an open mind so that we ....-Lenny Corin U.S.Ffsh and Wildlife Service April 27,1932 - 2 - - "... - .... ,rs- - m~have a constructfve session and work towards the common goal of obtaining satisfactory mitigation for wildlife/vegetation impacts associated with the Susitne Project. I look fowward to your attendance on the 17th and 18th. Sincerely, Michael Grubb Senior Scfentfst MG:ccv Enclosure cc:D.Wozniak -APA E.Reed -TES Mr.Karl Schneider Alaska Department of Fish and Game 333 Raspberry Road Anchorage,AK 99502 Dear Karl: April 28,1982 P5700.11.70 T.1687 Susi.tna Hydroelectric Project Mitigation Workshop As discussed.the workshop to discuss a habitat evaluation Iystem is scheduled for M~18th.at 8:30 a.m.,in room C109 of the Fedeaal Building, 6th and C Street,Anchorage.The workshop will be attended by members of the Sus1tna Wildlife Core Group and,for the first day,the U.S.Fish and Wildlife Service and ADF&G employees whom you select.The purpose of this workshop will be to reach consensus on: 1.Objectives of the habitat evaluation system. 2.A general approach to this system. Following this meeting,the Core Group will develop the technical details of the systan. I am enclos 1ng a Phase I Habitat Evaluation Report prepared by TES which applies a modified Konkel et al system to the impoundment zone and surrounding areas.I will.hopefully,also forward to you prior to the meeting a general system developed by Dr.Taber which m~be specifically applied to moose. It is nw intention to discuss these two systems,as well as HEP.at the workshop.I am asking all attendees to come with an open mind so that we may have a constructive session and works towards the common goal of obtaining satisfactory mitigation for wildlife/vegetation impacts associated with the Susitna Project.The Core Group will continue meeting on the 19th. 20th.and 21st (if necessary);please be available if at all possible. Thank you for your help. Sincerely, MG:ccv Enclosure ~1ichael Grubb Senior Scientiet Susi _t:::::tiyoroelectric Project Habi~Evaluation Meeting Date:'May 119,1982 Atterr~:See Attached List Held ~federal Building,Anchorage May 25,1982 - .- ..... The pWT?Dseof the meeting was to proceed with planning for habitat eva1- uatiorr,schemes. Karl Schneider explained more fully the Delphi approach.It involves a group Dfexperts assigning val ues to parcel s of land with the val ue repre':'" sentir,~their opinion on the quality of the habitat for a particular species. This 1S a more straight-forward and quicker process than the formal HEP proce~s.A similar exercise is conducted for mitigation lands.Karl Schnef::ler,Phil Gipson,and Brian Kessel will provide names to LGL on who they feel should be on the various panels. The cc'~cept of digitizing data was again discussed.This would be done by digitizing the vegetation mapping and utilizing ADF&G digitized moose and bear c~llar locations and then correlating the results.Karl Schneider and Steve Fancy will meet with USFWS to discuss the practicality of this approcch. An alternative method would be to use a cell approach.The study area would be divided by a grid system,with each cell being approximately 40 acres in size.The slope,elevation,grid,aspect,cover type and number of moose and bear sightings would be calculated for each grid and correla- tions developed. Karl Schneider,Dr.Taber and Jay have suggested a phenology study to better understand impact mechanism and to determine what foods and habitat charac- teristics moose are using during late winter and spring and determine the availability of those habitat characteristics inside and outside the area to be impacted.This study would involve determining moose food habits (through fecal analysis),measuring snow characteristics and emergence of vegetation and correlating it with elevation,slope and aspect.McKendrick is proceeding to set up transects in the field and equipment.He and Karl will be preparing a scope of work and budget for this.The stUdy will be repeated next spring.Seven transects in the Watana area and two in the Devil Canyon area will be established,with three points along each transect. Vegetation mapping may have to be expanded at the 111 =1 mile scale because current mapping does not include the home range of all moose in the area. Karl will develop a winter contingency budget to study moose distribution in case of a severe winter. Three impact zones need to be delineated;these are the primary impact zone, secondary or temporary impact zone and disturbance impact zone.The with and without project scenario must include the project area assuming no change Page 2 and also assuming what reasonable land use developments (mining,etc.)may occur.The future land items should be expressed to correlate with pro- posed dates for present study activities,construction,fillinq,operation. The browse studies to be conducted in the upper basin will begin in mid- July and end in mid-September. The BLM burn vegetation study will include base mapping at a 1:24,000 scale. Vegetation species list,composition and annual production studies will commence in July.ADF&G will plot baseline moose sighting information on the vegetation maps. The Jay Creek lick study by McKendrick will include soil analysis inside and outside the lick.Acres should attempt to determine what erosion patterns may occur. The species list of May 18 was studied and revised.Moose,black bear and brown bear were included as big game species as they best fit the estab- lished criteria.The other big game species did not.Birds chosen were the yellow-winged warbler,tree sparrow,golden eagle,and furbearers,the marten and beaver. MMG:dlp - Jay McKendrick Ph']1 Gipson Brian Kessel Kemneth Raedeke Richard Fl eming Michael Grubb Ri chard Taber Karl Schneider Joe McMullen Ed Reed Dot:<Helm ATTENDEES REPRESENTING University of Alaska University of Alaska University of Alaska Museum University of Washington Alaska Power Authority Acres American University of Washington Alaska Dept.of Fish &Game TES TES University of Alaska Susitna Hydroelectric Project Wildlife Mitigation Meeting Date:May 18,1982 Attendees:See Attached List Held at Federal Building,Anchorage May 25,1982 The purpose of this meeting was to discuss general objectives and general approach for a habitat evaluation system. A list of objectives for the system was developed (~ttachment 1).Ann Rappoport of USFWS presented an approach based on HEP.After much dis- cussion it was decided the approach taken would be to: 1.Develop criteria for selection of species for which habitat evaluation would be conducted. 2.Develop species list. 3.Develop habitat evaluation procedures for each species which will include field work or a Delphi session or both. 4.Test the procedures on a pilot program this summer,on small areas in and outside of impact area. Existing data would be utilized whenever possible.The habitat evaluation procedures would begin with the U of A subs and K.Schneider and lGl con- ducting Delphi sessions,reviewing the HEP models and determining what parameters and criteria should be utilized.Documentation was stressed. The Terror Lake situation was discussed as an example.The technical as- pects of this study for mitigation involved three afternoon sessions and 2-3 months of effort to obtain quantitative comparison of land for mitiga- tion. Official HEP models were discussed.Mucb concern'was expressed about their accuracy,applicability,validity and assumptions which must be used in their application.It was decided the TES report on habitat evaluation would not be suitable for mitigation purposes. Digitizing of data was discussed.Because of the large amount of time re- quired,it was felt it may not be cost effective for this project.Deci- sion would be based on development of habitat procedures.Available sources of infonnation incllJde: 1.Feasibility Report and Phase I Final Report. 2.TES/U of A prepared vegetative cover map,which are 1:24,000 in impoundment zone. 3.Digital Terrain model from USGS. 4.USFS-SCS vegetation data (digitized?)for Susitna Basin. 5.DNR land use plan for Talkeetna sub-basin and Willow sub-basin The criteria for species selection were developed (attachment 2)and the species list (attachment 3).The species list would be refined following closer examination of the criteria.It was decided indicator bird species were more appropriate than guilds. MMG:dlp - .... ,iIlliJitIl - ATTACHMENT 1 Objectives of Habitat Evaluation System 1.Integrate habitat characteristics with animal use 2.Quantify value of habitat lost 3.Utilize existing data,if possible 4.Determine mechanisms affecting wildlife 5.Quantify differential habitat values 6.Determine appropriate mitigation ATTACHMENT 2 Criteria for Selecting Wildlife Species 1.Consumptive use 2.Non-consumptive use 3.Ecological importance 4.Vulnerability to project disturbance 5.Responsiveness to mitigation 6.Species susceptible to habitat loss 7.Data availability and predictability of response - Michael Grubb Kenneth J.Raedeke Richard Fleming Brina Kessel Karl Schneider Carl Yamagawa Gary Stackhouse Steve Fancy Philip S.Gipson Joe tkMu 11 en Dot Helm Jay N.McKendrick Ed Reed Leonard P.Corin Greg Konkel Ann Rappoport Dick Taber ATTENDEES May 18,1982 Representing Acres American ; University of Washington APA University of Alaska Museum ADF&G ADF&G USFWS LGL Alaska AK.Coop.Wildlife Res.Unit TES University of Alaska University of Alaska TES USFWS USFWS USFWS University of Washington __________.kt-k'1d~_c-> j~-----------------------/'!J.fi.¥---l-B-r-lf~-~-------------------.------------ ,~ -----------_----N.5!"e...&~,~·--,----h ,.-el_l,-'t1:<.J GJl.!kh ~~_A_~l~~_f_?_ ___~~~j_.._~Ae.tekt.-"t/Aj\I.__*__~~~_ r-~\~.~Fl&.""';'Af'A __~....~___~-----..•..•_.....·.·UVlJv.A [tv>L.~~<A "'--..•.•. ,--ff/~~'JUP(,,/-.//,j)FV'-6:...-.. --F--(1Lj-}/;J42~4--------.-------____--,4p~~&-- -'~/X /.....;#f,u,.-r;,OKS.c--.._-.-.bg F w=:--..- _-"'__5t~~-----__J-(;-?-_k!a.sktL -;,.;P 4,i)/-----£C~.fh-l --------------14k'-~yd -4/../df(~~a,'~ J I!J~I'tc./'f.cU.•U.J ____ _~~__ -?-~3 \A ~~~'S.-_ v{<;FLuS U·S r=zl-~j ~bW~-.~ Ale••R....rch Auocllltea,Inc. 17 July 1982 Michael Grubb Acres American,Inc. The Liberty Bank Bldg. Main at Court Buffalo,NY 1420 Dear Michael: P.o.Box 80607,Fairbanks,Alaska 99708 (9071479-6519/479-2669 Telex 35·355 LGL Alaska recently became involved with the terrestrial environmental studies being conducted for the Susitna Hydroelectric Project.We are responsible for assessing the impacts of the project on vegetation and wildlife,using data collected by the Alaska Department of Fish and Game and our University of Alaska subcontractors.LGL is also responsible for developing a plan to mitigate any adverse impacts on terrestrial wildlife and vegetation. We will use systems analysis as a means for organizing the terrestrial environmental program.The attached document explains the reasons for using the approach and the steps involved in the process.We would like to invite you to a one-week workshop scheduled for 23-27 August 1982,to be held in the Ketchikan Room of the Anchorage Holiday Inn,beginning at 8:30 AM on the 23rd.The workshop will be intensively focused and will require long days from all.We have reserved a room for you at the Holiday Inn for Sunday through Friday nights,but you will need to make your own travel arrangements.Following the initial workshop,the mnde1 will be refined during one or two technical meetings (lasting 1 or 2 days each) with each subgroup in the fall,and during future modeling workshops to be held once or twice each year. LGL r S Program Manager is Dr.Robin Sener,who is located at our Anchorage office (274-5725).Dr.Joe Truett of LGL will be the workshop facilitator.The modeling team will be composed of modelers from LGL, Environmental and Social Systems Analysts (ESSA),and the Western Energy Land Use Team (USFWS)of Boulder.Colorado. We will be contacting you in person or by telephone to provide you with additional details on the workshop.We look forward to having you participate in the project,and hope you will find the approach to be a useful and realistic means for impact quantification and mitigation plan development.Please feel free to call me if you have any questions about the workshop. Sincerely, Robin Sener Program Manager SUSITNA HYDROELECTRIC PROJECT SIMULATION MODELING WORKSHOP FOR TERRESTRIAL WILDLIFE AND HABITAT Anchorage,Alaska August 23 -27,1982 - "... WORKSHOP OBJECTIVES 1.Develop a preliminary simulation model of hydrology,vegetation, and wildlife interactions in the Susitna Basin. --and through future refinements -- 2.Use the model to 'help predict and quantify project impacts to wildlife and habitat. 3.Use the model to help assess the probable effectiveness of proposed mitigation alternatives. WORKSHOP AGENDA Monday,August 23:8:30 AM -5:00 PM INTRODUCTION BOUNDING THE MODEL 0 Project Actions o Indi cators o Spatial Boundaries o Temporal Boundaries LOOKING OUTWARD 1 Tuesday,August 24:8:30 AM -5:00 PM LOOKING OUTWARD (Continued) SUB-MODEL DEVELOPMENT 7:30 -9:30 PM:DISCUSSION OF EVALUATION PROCEDURES Wednesday,August 25:8:30 AM -5:00 PM SUB-MODEL DEVELOPMENT (Continued) Thursday,August 26:8:30 AM -5:00 PM PRESENTATION OF SUB-MODELS DEVELOPMENT OF HYPOTHETICAL MITIGATION STRATEGIES Friday,August 26:8:30 AM -5:00 PM GAMING OF THE MODEL FUTURE DIRECTIONS (Discussion) 2 TERRESTRIAL ENVIRONMENTAL WORKSHOP Invited Participants ,...,. - Robert Mohn Dave Wozniak Eric Yould Richard Fleming George Gleason*Bob Weeden*Keith Bayha Gary Stackhouse Lenny Carin Ann Rappoport Al Carson Reed Stoops Marjorie Willits Keith Quintavell *Carl Yanagawa Karl Schneider Ron Modafferi Sterling Miller Warren Ballard Wayne "Regelin Tom Trent Bob Martin Bob Lamke Larry Wright Brad Smith Bill Lawrence Bill Riley John Rego Mike Scott Jay McKendrick Brina Kessel Phil Gipson Ed Murphy John Hayden Mike Grubb Bob Butera *Bruce Apple Dave Cline Roland Shanks Alaska Power Authority Alaska Power Authority Alaska Power Authority Alaska Power Authority Alaska Power Authority Alaska Power Authority/University of Alaska U.S.Fish and Wildlife Service U.s.Fish and Wildlife S~rvice U.S.Fish and Wildlife Service U.S.Fish and Wildlife Service Alaska Department of Natural Resources Alaska Department of Natural Resources Alaska Department of Natural Resources Alaska Department of Natural Resources Alaska Department of Fish and Game Alaska Department of Fish and Game Alaska Department of Fish and Game Alaska Department of Fish and Game Alaska Department of Fish and Game Alaska Department of Fish and Game Alaska Department of Fish and Game Alaska Department of Environmental Conservation U.S.Geological Survey National Park Service National Marine Fisheries Service Environmental Protection Agency Environmental Protection Agency Bureau of Land Management Bureau of Land Management University of Alaska University of Alaska University of Alaska University of Alaska Acres American Acres American R&M Consultants National ~ildlife Federation National Audubon Society Cook Inlet Region,Inc. *will not be able to attend SUSITNA HYDROELECTRIC PROJECT TERRESTRIAL ENVIRONMENTAL WORKSHOP 23-27 August 1982 INTRODUCTION The technical feasibility,economic viability,and environmental impacts of a hydroelectric development in the Susitna River Basin are being studied by Acres American,Inc.(Acres)on behalf of the Alaska Power Authority.As part of these studie~,Acres recently contracted LGL Alaska Research Associates,Inc.(LGL)to coordinate the terrestrial environmental studies being performed by the Alaska Department of Fish and Game and,as subcpntractors to LGL,several University of Alaska research groups.LGL is responsible for further quantifying the potential impacts of the project on terrestrial wildlife and vegetation,and for developing a plan to mitigate adverse impacts ~n the terrestrial environment.The impact assessment and mitigation plan will be included as part of a license application to the Federal Energy Regulatory Commission (FERC)scheduled for the first quarter of 1983. The quantification of impacts,mitigation planning,and design of future research is being organized using a computer simulation modelling approach.Through a series of workshops attended by researchers,resource managers,and policy-makers,a computer model is being developed and refined.This model will assist project personnel in identifying impacts on terrestrial wildlife and vegetation and in evaluating different mitigation measures such as habitat enhancement and the designation of replacement lands to be managed as wildlife habitat.The simulation modelling approach is being used for the following reasons: 1.It provides a means to incorporate and coordinate the professional judgments of scientists I resource managers, and policy-makers.Mitigation planning will include many subjective evaluations,and therefore all parties must -maintain continuing communication program. throughout the ..... -- 2.It utilizes existing data to focus future research in areas that are decided by the workshop participants to be the most important.The approach will also insure that the data are collected in the proper units,sampling schemes, and time-frames to promote integration of data from the different disciplines (e.g.,hydrology,furbearers, vegetation). 3.It allows great flexibility.'The selected indicators (environmental items of interest)can include population attributes (e.g.,cha,nges in the number of beavers with and without the project,and with different mitigation options);habitat units or important descriptive variables (e.g.,amount of browse available in late winter);or any number of alternative indicators as selected by the workshop participants.Data on habitat,predation, weather,and other biophysical system components is incorporated into the models as needed. Eventually,.the model will represent the best available understanding of the biophysical system,and as such will provide an '!ecological laboratoryn for helping to evaluate mitigation options. The mitigation plan will be developed in two steps,an immediate effort based on eXisting.data,and a longer-term effort that will apply data yet to be gathered.Some mitigation measures,such as controlling dust along roads,leaving clumps of trees along the reservoir margin for eagle nesting,minimizing aircraft disturbance,and locating recreation facilities away from critical wildlife areas,are rather easily defined and agreed to,and these measures will be developed prior to submittal of the FERC application to allow adequate time for incorporation into project design and the application.It is recognized, however,that final agreement on some mitigation measures such as habitat enhancement or compensation lands may require several more years of research and discussion,and that the mitigation plan must be flexible to allow changes necessitated by information from long-term monitoring studies.Thus the final comprehensive mitigation plan will not be.complete at the time of license application submittal,but the modelling workshops provide a framework for development of the final plan by increasing communication between scientists and policy-makers. WORKSHOP ACTIVITIES The intitial simulation model was constructed during the one-week workshop held in Anchorage 23-27 August.1982.The participants at the workshop are listed in Table 1.The workshop facilitators were members of LGL Alaska (Fairbanks and Anchorage).ESSA E"nvironmental and Social Systems Analysts Ltd.(Vancouver.Canada),and U.S.Fish and Wildlife Service (USFWS)personnel from the Western Energy and Land Use Team (WELUT)office in Fort Collins.Colorado. The main objective of the workshop was to initiate development of a dynamic simulation model of the hydrology/wildlife/vegetation system in the Susitna Basin.The participants provided the knowledge of the system;the facilitators translated that knowledge first in to a conceptual model and then into computer code. Bounding On the first day of the workshop,the bounds of the model were defined.The first step in this exercise involved defining all the actions to which we wanted the model to respond.In the context of the model,the actions were the various activities associated with construction and operation of the impoundments and the current collection of mitigation activities (Table 2). The next step in the bounding exercise was the identification of the key indicators (environmental attributes of interest such as moose numbers,habitat quality,etc.)for which the model must be able to generate values over time.The predicted changes in these indicators are used to help determine the impacts of an action,and in turn, evaluate the quantity,quality and timing of appropriate mitigation Table 1.Participants in Susitna Terrestrial Modelling Workshop,23-27 September 1982. NAME Tom Arminski Greg Auble Warren Ballard AFFILIATION Alaska Department of Fish and Game USFWS -WELUT Alaska Department of Fish and Gam~ ADDRESS 333 Raspberry Road Anchorage,AK 99502 2625 Redwing Road Fort Collins,CO 80526 P.O.Box 47 Glennallen,AK 99588 Bruce Bedard Alaska Power Authority 334 -5th Avenue Anchorage,AK 99501 Steve Bredthauer R&M Consultants Leonard Corin USFWS Ike Ellison USFWS ~WELUT P.O.Box 6087 5025 Cordova Street Anchorage,AK 99503 605 West 4th,ltG-81 Anchorage,AK 99501 2625 Redwing Road Fort Collins,CO 80526 - John Ernst Bob "Everitt Steve Fancy LGL ESSA Ltd. LGL 1577 "C"Street Anchorage,AK 99501 678 West Broadway Vancouver,B.C. P.O.Box 80607 Fairbanks,AK 99708 Richard Fleming Bill Gazey Philip Gipson Alaska Power Authority 334 -5th Avenue Anchorage,AK 99501 LGL 1410 Cavitt Street Bryan,TX 77840 Alaska Cooperative University of Alaska Wildlife Research Unit Fairbanks,AK 99701 Table 1 (continued) NAME Michael Grubb John Hayden Dot Helm Brina Kessel Sterling Miller Suzanne Miller Carl Neufelder Wayne Regelin Butch Roelle David Roseneau Karl Schneider Robin Sener Nicholas Sonntag Robert Starling AFFILIATION Acres American Acres American University of Alaska Agricultural Experi- ment Station University of Alaska Museum Alaska Department of Fish and Game Alaska Department of Fish and Game Bureau of Land Management Alaska Department of Fish and Game USFWS -WELUT LGL Alaska Department of Fish and Game LGL ESSA Ltd. NORTEC ADDRESS 900 Liberty Bank Building Buffalo,NY 14202 1577 nc"Street Anchorage,AK 99501 P.O.Box AE Palmer,AK 99645 P.O.Box 80211 Fairbanks,AK 99708 333 Raspberry Road Anchorage,AK 99502 333 Raspberry Road Anchorage,AK 99502 4700 East 72nd Avenue Anchorage,AK 99501 1300 College Road Fairbanks,AK 99701 2625 Redwing Road Fort Collins,CO 8052fj P.O.Box 80607 Fairbanks,AK 99708 333 Raspberry Road Anchorage.AK 99502 1577 "c"Street Anchorage,AK 99501 678 West Broadway Vancouver,B.C. 750 West 2nd Avenue,#100 Anchorage,AK 99501 ~. Table 1 (continued) NAME Bill Steigers Thomas Trent Joe Truett Larry Underwood Jack Whitman Marjorie Willits AFFILIATION University of Alaska Agricultural Experi- ment Station Alaska Department of Fish and Game, SU Hydro Aquatic LGL AEIDC Alaska Department of Fish and Game Alaska Department of Natural Resources ADDRESS P.O.Box AE Palmer,AK 99645 2207 Spenard Road Anchorage,AK 99503 P.O.Box 1745 Grand Junction,CO 81502 707 tI At!Street Anchorage,AK 99501 P ..O.Box 47 Glennallen,AK 99588 555 Cordova Street Anchorage,AK 99510 Table 2.Actions identified at Sustina Terrestrial Modelling Workshop, 23-27 August 1982.Exactly how these are implemented in the model will be described in a later report. I.Reservoirs a.Construction •road building ..borrow pits •transmission lines •camp sites •village sites •temporary diversions •mining of river bed •reservoir clearing •disposal of spoil ..construction of air strip •aircraft use •staging areas b.Operation •operating rule curves II.Recreation/Access •reservoir recreational development (access and facilities •recreational use (backbacking,hunting,fishing) •increased traffic on existing roads/railroads III.General •timber harvest •changes in land use patterns (mining,oil and gas development) •increased population in surrounding communities IV.Mitigation •habi tat enhancement controlled burn fire protection . vegetation crushing •flow regulation for fish'and wildlife •control of access •hunting/fishing regulation •scheduling of construction activities •siting of roads ..reclamation/revegetation actions.The indicators identified at the workshop are shown in Table 3. After establishing the actions and indicators,the next step was the definition of the spatial and temporal bounds of the model. Spatially the area was divided at Devil Canyon into the upstream portion and downstream portion of the Susitna River (Figure 1). The upstream area included all of the upper Susitna Basin and the.- Prairie Creek-Stephan Lakes area.Within the upstream area the Watana and Devil Canyon impoundment areas were considered separately. The region downstream of Devil Canyon was separated into two units --an area on each side of the river,paralleling it and extending away from the river the estimated maximum diameter of a moose's home range.Currently the area considered by the model extends as far downstream as Talkeetna.Because the effects of the project downstream of Talkeetna will be tempered by the contributions of the Chulitna and Talkeetna rivers and other tributaries,hydrological and vegetation data south of that confluence have not been collected in as much detail as north of Talkeetna. Within both upstream and downstream areas,the flood plain and upland habitats were considered separately,such that a floodplain area was defined within each of the four major spatial divisions.Each floodplain and non-floodplain area was further subdivided into vegetation types,of which there are fourteen in the project area (Table 4). The chosen time step of the model was annual,although each subsystem had the option of developing time dynamics on a shorter scale if appropriate.The time horizon for the model runs was set at 70 to 80 years. The final step in bounding the model,the IIlooking-outward" exercise,involved first dividing the system as defined up to this point (Le.,the actions,indicators,space and time)into four disciplinary subsystems.The subsystems were: Table 3.Indicators identified at Susitna Terrestrial Modelling Workshop.23-27 August 1982. Hydrology ..instream flows Vegetation ..hectares of selected vegetation types Wildlife ..population levels of:moose black bear brown bear sheep wolves raptors caribou wolverine small mammals selected birds ..carrying capacity of habitat for the above populations ..species diversity of birds ..numbers of animals harvested by hunters ..hunter success ..habitat quality Recreation ..number of user days ..non-consumptive uses of wild)ife J 1 J -.]J 1 i ]1 1 "I ;.... .". / / / I eM/ilM I ,R/.".r 'f'-.. I,,., I I I I L_.:- WILLOW '.-l:~~~N \~--"iJ ..~.....--~~j ,'- I ~~( I ., L-_---"....-.......--....I,-,,........ ,,~---,I'....., .......--.....~- MILES o '10 20 '.,;;po102030 KILOMETERS Figure 1:'Suggested boundaries for study area and subareas for simulation modeling purposes. Table 4.The vegetation types found on the Susitna Hydro Project Area. Conifer forest -woodland -open Deciduous and Mixed Forest Tundra Tall shrub -alder Medium Shrub Low shrub -birch -willow -mixed Unvegetated -water -rockl snow lice Disturbed -temporary -permanent Pioneer Hydrology I Development I Land Use I Recreation Vegetation Furbearers/Birds Large Mammals Participants \Vere then separated into four subgroups.Each subgroup,with the help of one of the workshop facilitators,began building a computer model of one of the subsystems.The interactions between each subsystem were defined by filling in the "looking-outward matrix"(Figure 2).To do so the participants in each subgroup identified what information they required from the other subsystems in order to build their submodel. Submodel Construction J At the conclusion of the "looking-outward"exercise,each subgroup had all the information required to construct and code its sub model independently of the rest of the participants.Where possible, data from the Susitna basin were incorporated into the structure of each sub model.In the absence of data,the expertise of the participants was used to develop hypotheses to help refine the structure --hypotheses that hopefully could be tested in future field work and/or analysis. Scenario Construction On Thursday afternoon,the workshop participants discussed a number of representative'construction (action)and mitigation scenarios to be tried on the model.Three scenarios were developed.The first was the no-project option to establish indicator behavior under undisturbed conditions.The second was the construction of the complete project (Watana and Devil Canyon)using the optimum flow regime for power generation..The third scenario considered Watana development only,had restricted access to the area by the public,and Figure Z.looking Outward Matrix Ilydro 1ogy/Deve 1opment Recreation Hydrology/Development Recreati on Vegetati on Furbearers/Birds large MaJMlills ~, i Vegetation, - 3 day peak flows -locations and hectares of development activities -surface area exposed in floodplain -hectares of intensive beaver use by vegetation type -consumption (kg/ha)of forage species by season and type Furbearers/Birds -date of breakup,freezeup on lakes,ponds,streams -date of first snow cover and exposure of 301 -km of open water in river -km of sloughs and side channels with at least .5 m of unfrozen water -reservoir elevations -levels of human disturbance -areas of vegetation types (ha) -productivity (kg/ha)of: Paper bi rch Balsam poplar Birch sh rubs Bl ack spruce White spruce Hillow spruce Aspen la rge Manmals -date of ice breakup -amount of ice shelving March 15 to June 15 -snow depths at 150 m elevation intervals, monthly -trips/day on access road by season -train trips/day,Nov-Mar -recreational use days -areas of vegetation types (ha) -ha of berries suitable for bear food production of berries (kg/ha) -standing crop (kg/ha)of Paper bl rch Balsam poplar Wi 11 ow shrub Aspen lowbush Cranberry -- used the flow regime considered best for maintaining instream flow requirements of wildlife.Little experimentation with mitigation options was carried out at this stage.largely due -to the preliminary state of the model and the available time.The workshop report will discuss these and other scenarios in more depth. EVALUATION Ultimately in the development of any mitigation strategy there is a need to evaluate the alternatives and select the preferred option. However.the major difficulty is structuring the evaluation.When dealing with a possible change in wildlife populations or available habitat as a consequence of the project.putting value on that change is invariably subjective and open to criticism.In any case.such evaluations are necessary both in evaluating mitigation options as well as establishing appropriate compensation. Ultimately.the simulation model developed at the workshop will help in the evaluation of mitigation options.Exactly how they will be evaluated is.at this time.not certain.Various approaches have been applied in the past (e.g .•Habitat Evaluation Procedures (HEP).Rapid Assessment Methodology (RAM).or Delphi).some with more success than others.Although "evaluation"as an issue was not the subject of this first workshop.an evening discussion (facilitated by Ann Rappaport of the USFWS)was held on this topic to initiate development of some of the ideas to be pursued after the workshop. REPORT The workshop report is now being prepared by the workshop facilitators/modellers.This report will summarize the workshop activities and give detailed descriptions of each of the submodels.It will also discuss the relationship between mitigation planning and the modelling effort as well as the major research needs identified by the workshop participants. NAME SUSITNA TERRESTRIAL MODELING WORKSHOP AUGUST 23 -27,1982 AFFILIATION ADDRESS ....Bob Everitt """Joe Truett David G.Roseneau.... Steve Fancy Philip s.Gipson ESSA Ltd. LGL LGL LGL AI<Coop.Wldl.Res.Unit 678 W.Broadway,Vancouver,B.C. 604-872-0691 P.O.Box 1745,Grand Jet.,CO 81502 P.O.Box 80607,Fbnx,AK 99708 907-479-2669 P.O.Box 80607,Fbnx,AK 99708 907-479-2669 Uni.of AlC,Fbnx,AK 99701 .....Ann G.Rappoport USFWS-Western AI<Ecological Serr.605 W.4th #G-8l,Anch,AK 99501 Larry M.Wright Leonard P.Carin Thomas W.Trent Carl Neufelder Richard Fleming Tom Arminski ,.... Michael Grubb ~Bruce R.Bedard Warren Ballard-Nancy Tankersley Karl Schneider John Hayden ....Bill Gazey Greg Auble ,.... Ike Eillison """ Nat'l Park Ser. USF &WS ADF &G,SU Hydro Aquatic BLM -Anch. AI<Power Authority AI<Dept.of Fish &Game Acres American AI<Power Authority AK Dept.of Fish &Game AI<Dpet.of Fish &Game AI<Dept.of Fish &Game Acres American LGL USFWS-Welut USFWS-Welut CONTINUED 540 W.5th,Aneh,AlC 99501 605 W.4th,#G-8l,Anch.AI<99501 2207 Spenard Rd.Anch,AK 99503 4700 E.72 Ave,Anch,AK 99507 334 5th Ave,Anch,AK 99501 333 Raspberry Rd.Anch,AlC 99502 900 Liberty Bank Bldg. Buffalo,NY 14202 334 5th Ave,Anch,AK 99501 P.O.Box 47,Glennallen,AI<99588 333 Raspberry Rd.,Anch,AI<99502 333 Raspberry Rd.,Anch,AI<99502 1577 "c"St.Anch,AI<99501 1410 Cavitt St.Bryan,TX 77840 2625 Redwing Rd. Fort Collins,CO e0526 2625 Redwing Rd. Fort Collins,CO 80526 NAME Steve Bredthauer Brina Kessel Majorie Willits Butch Roelle Wayne Regelin Bill Steigers Dot Helm Robin Sener Nicholas Sonntag John Ernst Suzanne Miller Sterling Miller Jack Whitman Robert N.Starling AFFILIATION R & M Consultants Univ.AK Museum AI<Dept.of Natural Res. USFWS-Welut AI<Dept.of Fish··&Game Univ.AI<Ag.Exp.Sta. Univ.AK.Ag.Exp.Sta. LGL ESSA Ltd. LGL AI<Dept.of Fish &Game AK Dept.of Fish &Game AI<Dept of Fish &Game Nortec ADDRESS P.O.Box 6087,5024 Cordova Anch.AI<99503 P.O.Box 80211,Oollege,AK 99703 555 Cordova St.Anch,AI<99510 2625 Redwing Rd. Fort Collins,CO 80526 1300 College Rd.Fbnx,AK 99701 P.O.Box AE,Palmer,AI<99645 P.O.Box AE,Palmer,AK 99645 1577 "c"St.Anch.,AI<99501 678 W.Broadway,Vancouver,B.C. 1577 "c"St.Anch,AI(99501 333 Raspberry Rd.Anch,AK 99502 333 Raspberry Rd.Anch,AI<99502 P.O.Box 47,Glennallen,AK 99588 750 W.2nd Ave,Suite 100 Anch,AK 99501 Larry Underwood AEIDC 707 "A"St.Anch,AK 99501 UNITED STATES GOVERNMENT memorandum L Cr L R E Co 'b a II e,J8 2...ea~ ceo:~IC~~b FL.EHtA.JGr U.s.FISH Q~~Di:rr~~~~CE WESTERN ALASKA ECOLOGICAL SERVICES 733 W.4th Avenue,Suite 101 Anchorage,Alaska 99501 (907)271-4575 c.Co :SO ~1J J·h~t yhEN STE'ol Co tAN '-" TO:Su Hydro Files FROM:Ann Rappoport,Fish &Wildlife Biologist -)/yv"-- SUBJECT:Beaver Survey,Talkeetna to Montana Creek DATE:~8 AUG 198Z .... .... On August 5 and 6,I joined Jim Durst and Dave Volsen of the University of Alaska,Fairbanks,on the second of their three downstream beaver surveys for the proposed Susitna hydroelectric project.We surveyed 11 sample miles within the 24 mile stretch of the Susitna River from just below its confluence with Montana Creek to Talkeetna.Purpose of my participation was to familiarize myself with data being collected and determine the applicability of HEP to the Su Hydro beaver study. Jim,Dave,and principal investigator,Dr.Phil Gipson,had previously surveyed the Takeetna to Devil's Canyon portion of the Susitna River;Phil was to join them the next week for the remaining survey from Montana Creek to the Delta Islands.Upstream areas had been briefly evaluated during the previous year's furbearer work.An aerial count of food caches will be undertaken this fall. Following is a brief description of the beaver survey methodology,qualitative study findings,data needs and applicability of HEP. Methodology Traveled upriver in University's 20'riverboat.River miles had been marked Itl1d rll/Jllh~r£!d on J H ..1,000'blnck Illul Ithttl1 phor II Ii wt r II OnH nllmhHr (tJr t.llt!tHUit river bank and one number for the west river bank.One river mile long sample sites were surveyed by boat.Sloughs and freshwater streams adjacent to those sample miles and within the area expected to be impacted by project-caused flow changes were also surveyed.Where impossible to survey an area by boat or foot,a helicopter was to be used the following week.Data collected included:beaver sign (tracks,cuttings,"skid"trails,lodges,bank burrows, and dens),bank type (e.g.mud,rock,etc.),water depth,water velocity, dominant tree and shrub cover type~other wildlife sign,and presence or sign of human disturbance • R7·J Qualitative results Eleven sample sites were surveyed.Each site consisted of one mile stretch of river bank along one side of the river and the adjacent sloughs and streams. River banks were typically heavily vegetated and ranged from 1 -3'in height to 40-50'with gravel rocks to 6"or bare mud at the water's edge.Occasional exposed.barren cliffs of 30-50'in height were also present.Vegetation along the river is primarily deciduous.Dense alder to 30'predominated with some interspersed tall willow shrubs.The cottonwood and birch overs tory ranged from open to closed with intermixed spruce along the top of the banks. Devil's club.ferns.berries (high bush cranberry.elderberry.and wild rose). and grass typically £omprised the understory.Willow and poplar seedlings were usually scattered in the grass/sedge/equisitum cover on flats and vegetated islands. At least three beaver were observed during the survey.Beaver sign (tracks along mud banks.cuttings of willow and poplar (one cut alder was found). "skid"trails where cut vegetation has been dragged to the water.and beaver lodges and dams was common in areas of suitable habitat.Key factors contributing to suitable habitat were: (1)sloughs or clear-water streams of slower-moving water adjacent to the main river channel;apparently limiting water velocities are unknown; (2)availability of food -University researchers are preliminarily concluding that lack of willow limits beaver use along the Susitna River.It is unknown why alder is the early successional stage rather than willow in some locations is unknown. (3)banks which provide stable substrates for burrowing; (4)absence of human disturbance --a few areas of highly suitable habitat (i.e.willow was present,side sloughs and sand/mud banks offered suitable building sites)lacked any beaver sign.Howe;er in all cases these areas were easily accessible to the road and supported an enthusiastic population of 10-20 fisherpersons and abundant empty beer cans and other trash;and (5)at least 30"water depth in winter. Data Needs/Applicability of HEP Lack of information on both vegetation succession and the hydrologic regime anticipated with project development are the major limitations to determining project impacts to beaver.Data being collected should provide a good baseline assessment of beaver populations and habitat uses downstream of the Devil's Canyon dam si~e.A baseline HEP analysis could likely be performed with existing data and the University of Alaska researchers'input. I discussed HEP with Jim and Dave.They were interested to learn of the availability of color IR photos of the area (from U.s.SCS/FS studies of the Susitna River Basin)which could help in identifying v~getation cover in areas not directly surveyed.We considered ways of modifying the beaver habitat model as was done for the Bradley Lake and Willow Subbasin studies,yet the model could be improved with the site information collected for the Susitna project.Model modification should involve assigning suitability index values on the basis of available water plus adjacent suitable vegetation cover. cc:FW'S-ROES Lenny Corin,WAES Phil Gipso'n,Uni versi ty of Alaska,Fairbanks Robin Sener~LGL APPENDIX EllH COMMENTS RECEIVED DURING,NOVEMBER 1982 WORKSHOP APPENDIX 11.H MEETING NOTES FROM NOVEMBER WORKSHOP - On November 15~1982,a Draft Exhibit E of the license application was ,-distributed to the appropriate federal,state,and local agencies for'review and comment.To assi~t agencies in reviewing the Draft Exhibit E~a four-day workshop was held in Anchorage from November 29 to December 2~1982. This appendix contains a list of agencies that were sent the Draft Exhibit E and notes of the workshop meetings. - P5700.70.0100-00 SUSITNA HYDROELECTRIC PROJECT FERC License Application Exhibit E Presentation and Discussion Anchorage,Alaska Holiday Inn November 29 -December 2,1982 Obj ec t i ves 1.Update Federal,State and local agencies regarding significant changes in project features since the Feasibility Report was published in March,1982. 2.Use the presentations and discussions as an interactive process whereby Federal,State and local agency review of the draft Exhibit E can be facilitated. 3.Develop a mechanism for continued interaction as the finalized Exhibit E is prepared for submission to FERC. AGENDA 1:00 P.M.Monday,Novanber 29 Introduction Project Operational Description Wa ta na Darn Devil Canyon Dam Access Transmi ss ion Schedule for Preparation of Exhibit E Group Definition Tuesday,November 30 9:00 A.M. Group Water Use and Quality and Fishery Resources (l4.Oyck,L.MouttOIl, Group 2 Wildlife and Botanical Resources (R.Sener,M.Grubb) Group 3 Socioeconomic/Land Use (P.Rogers,P.Lukens,K.Young) Group 4 Cultural Resources (G.Smith,D.Follows) Wednesday,December 1 9:00 A.M. Group Water Use and Quality and Fishery Resources Group 2 Wildlife and Botanical Resources Group 3 Recreation and Aesthetics (R.Erickson,J.Chappell) Thursday,December 2 9:00 A.M. Group 1 Water Use and Quality and Fishery Resources Group 2 Wildlife and Botanical Resources LIST OF ATTENDEES SUSITNA HYDROELECTRIC PROJECT WORKSHOP Holiday Inn,Anchorage,AK Monday,November 29,1982 - - Name Michael P.Storonsky Philip Hoover Thomas Lavender Tony Burgess Michael Grubb Charlotte Thomas Steve Fancy Martha Raynolds Robert Sener Dave Tremont Ro 1and Shanks Priscilla Lukens Michele Urban Tom Arminski Leonard Corin Larry Moulton Jean Baldridge Keith Quintavell Robert Mohn George Gleason John Bizer Jack Robinson Randy Fairbanks Gary Lawley George S.Smith E.James Dixon B.Agnes Brown Carole A.Ellerbee Robert M.Erickson Tim Smith Richard Fleming Bob Madison Bob Lamke Bob Martin Don McKay George Cunningham Randy Cowart Al Carson Paul Janke Gary Prokosch Mary Lu Harl e Robi n Hi 11 Peter Rogers Steve Zrake Organization Acres Acres Acres Acres Acres Alaska Power Authority LGL Alaska LGL Alaska LGL Alaska Dept.,CorTmulJity Regional Affairs Cook Inlet Region,Inc. Acres Harza/Ebasco Alaska Power Authority tJSFWS Woodward-Clyde Woodward-Clyde DNR -DLWM Alaska Power Authority Alaska Power Authority Harza/Ebasco Ha rza/Ebasco Ha rza/Ebasco Harza/Ebasco University of AK Museum University of AK Museum Tyonek Native Corp. Tyonek Native Corp. EDAW,Inc. DNR-Parks (History and Archaeology) Alaska Power Authority USGS-WRD USGS-WRD ADEC ADF&G ADF&G ADNR-R&D ADNR ADNR ADNR-Water ADNR-Water Management Frank Orth &Associates Frank Orth &Associates ADEC Telephone 276-4888 II II II 716 -853-7525 276-0001 479 ...2669 274-5714 274-5714 264-2206 274-8638 276-4888 277-1561 276-0001 271-4575 276-2335 276-2335 276-2653 276-0001 II 277-1561 II 474-7818 " 272-4548 " 274-3036 264-2139 276-0001 271-4138 II 274-2533 267-2284 344-0541 276-2653 276-2653 II 276-2653 II 206-455-3507 II 274-2533 LIST OF ATTENDEES -cant .. Name Jan Hall Gary Stackhouse Brad Smith Bill Lawrence Floyd Sharrock Bruce Bedard Ann Rappoport Bob Everett Eric Myers John Rego Lee Adler Bill Wilson Chris Godfrey Ted Rockwell Larry M.Wright Organization USFWS USFWS NMFS U.S.EPA NPS Alaska Power Authority USFWS-WAES ESSA Ltd. NAEC BU~ AHTNA Inc. AU DC COE USCE Reg.Function NPS Telephone 263-3403 263-3475 271-5006 271-5083 271-4216 276-0001 271-4575 274-5714 276-4244 267-1273 822-3476 279-4523 552-4942 II 271-4236 LIST OF ABBREVIATIONS USED FOR AGENCIES Alaska Power Authority Alaska Department of Community and Regional Affairs Alaska Department of Environmental Conservation Alaska Department of Fish and Game Alaska Department of Natural Resources Artic Environmental Information and Data Center (University of Alaska) Cook Inlet Region,Inc. National Marine Fisheries Service National Parks Service Northern Alaska Environmental Center United States Bureau of Land Management United States Corps of Engineers United States Environmental Protection Agency United States Fish and Wildlife Service APA ADCRA AOEC ADF&G ADNR AEIDC CIRI NMFS NPS NAEC BLM COE USEPA USFWS -Minutes of Meeting - Subject:Susitna Hydroelectric Project Workshop -FERC License Application Exhibit E,Presentation and Discussion Location:Holiday Inn,Anchorage,Alaska Attendees:see attached Date:Monday,November 29,1982 1:00 P.M. Minutes recorded by:Michael P.Storonsky 1.Introduction -Dr.Richard Fleming (APA) A) B) Summary: Dr.Fleming schedu le of attendees. Purpose of To provide attendees. document to provided an overview of the purpose of the workshop,the the license application process and introduced some of the Workshop: an informal informational session for the various agency Solicit comments and concerns to improve the final license be submitted to the FERC. C)~Wl ic~t icon: submitted draft Exhib it £to the FERC and the various agencies November 15,1982 -workshop November 29 -December 2 prepare and distribute a copy of the minutes of workshop week of December 6 -incorporating agency comments into draft as received -meet with FERC staff 14 December to review Engineering Exhibits meeting with the FERC staff December 28 to receive their comments on Exhibit E of draft application -agency comments due January 15,1983 -submitting license application to the FERC February 15,1983 - a sllpplementary report of 1982 fisheries information and analysis to be submitted in June 1983. -additional supplemental information as required. 0)Introduced representatives of the Harza/Ebascol team that will be handling Phase II of the Susitna Project. II.Project Operational Description -Dr.John Hayden (Acres) A)Summary Dr.Hayden first provided a slide presentation of the major project features and location t and then a series of overhead viewgraphs of the filling and operational processes.Through the use of wall maps Or. Hayden provided a description of the access routes and transmission lines t their locations and schedules of development.Following an intermission Dr.Hayden outlined the organization of the workshop for the ba1ance of the week. I~ B)Major Project features -Watana -overview of the drainage basin and the relative position of the dams -location of the proposed damsite looking both upstream and dDwnstream -location of the proposed borrow areas D&E t existing field camp, intake tunnel,emergency spillway project features discussed incltJding the 54 mi le length of reservoir t upstream boundary -just above the confluence with the Oshetna River, site of construction camp and villa.ge,and location of access road -construction development schedule described •access road construction ·diversion tunnel excavation •completion of diversion cofferdams •diversion of water through 2 tunnels,to be ultimately sealed •plug tunnels 4 - 5 years into construction .and begin fi 11ing reservoir complete dam,power facilities and above ground structures -operation •1993 • 6 units x 170 MW =1020 MW 120'depth of intake structures rather than previous 140'depth · 4 intakes levels outlet facilities main spillway for floods>1:50 years •emergency spillway for flood>1:10,000 years. C)Devil Canyon Project Features -location of the proposed site looking both upstream and downstream -pertinent features ·access routes •borrow area locations powerhouse location on north side of river ·long tailrace proposed to provide additional head • 4 units at 150 MW =600 MW Total capacity •Fixed-cone values will be used to maintain instream flow during filling as well as prevent gas supersaturation during operation. •multiple level intake structure - 2 intakes within upper 50 feet of the reservoir. -Operational Data •50'drawdown in August of some years •commissioning date 2002 D)Filling and Operation Processes (i)Mimimum flow requirements at Gold Creek -Filling 1000 cfs in winter 6000 cfs in spring •flows spiked to 12,000 cfs in August and through mid Sept. -Operation •5,000 cfs in winter •spring and summer same as during filling -- .- (ii)Filling Process for Three Filling Scenarios Based Upon the 32 Years of Historical Hydrologic Data -three year filling flow scenarios examined with .90%chance of exceedence 50%chance of exceedence .10%chance of exceedence -filling begins 1991 -1993 -not a lot of difference between 3 scenarios (iii)Comparison of Monthly Average Pre-prdject and Filling Flows at Gold Creek,Sunshine and Susitna Station -greatest %change in the summer time (iv)Operational Water Levels at Watana -normal maximum elevation 2185 1 -surcharged to 2190'during September after the risk of floods diminished -mean drawdown 105 1 -maximum drawdown 120 1 -maximum,minimum and mean drawdown scenarios compared -very slight water level change with Devil Canyon on line (v)Devil Canyon Water Levels -wet years;reservoir full all year -mean years;501 drawdown in August and September with filling as rapidly as possible in October -dry years;slight drawdowns during April -May also (vi)Comparison of Monthly and Annual Pre-project and Post-project flows with Watana alone and with both projects on line (vii)Operation of Projects -Watana alone will be operated as a base-load plant -with Devil Canyon on line,Watana will be peaked and Devil Canyon wi 11 be base-load (viii)Temperature conditions -modeling taking place -may need to consider a low-level intake to achieve more desirable fall temperatures E)Access Roads -wall maps (i)Watana Route -rai lroad transfer point at Cantwell -use Denali Highway for 21 miles to Watana access road from Denali Highway,43 miles south to damsite (ii)Construction Schedule -Watana -begin immediately after issuance of license -construct a primitive access road from Denali Highway to Watana damsite first -within 1 - 2 years upgrade to allow for additional construction traffic -following 1993 it is uncertain as to whether the access road will be public or private,this decision will be made at a later date (iii)Devil Canyon road from·Watana to Devil Canyon north of river railroad access from Gold Creek to damsite,south of river -schedule not as critical -public vs.private road to be decided at a later date F)Transmission Line -two lines from Watana to the intertie -two lines from Devil Canyon to the intertie -winter construction of a significant portion of corridor,therefore avoid need for "access road" -use existing trail from Cheechako Creek to the intertie G)Other -pursuant to a question from the audience -•outlined project boundary •identified land holdings in the area:native~private and state -set of drawings of project reproduced from Exhibit F provided INTERIYlISSION H)Organization for Balance of Workshop Identified groups~group leaders~and locations and times of meetings -(see attached agenda). MEETING ADJOURNED ..... SYNOPSIS OF WORKSHOP ON SOCIOECONOMICS NOVEMBER 30,1982 Frank Orth &Associates,Inc.lead a discussion In which the following topics were addressed:objectives of Section 5 of Exhibit E;the methodology and assumptions used fn the socioeconomic analysis;the major areas of impacts; and the proposed mit I gat i on process.Cop f es of the agenda and the list of part icI pants for th Is workshop are attached.Si gn If Icant issues brought up by participants are summarized below: I.It was requested that clarification be provided on the reasons that impacts resulting from the use of the power that the project wi I I prov I de are not I nc I uded In the FERC license app II cat ion.0i scuss Ion fol lowed on the distinction between direct/indirect and Induced impacts. 2.The posslbl I lty of dam fal lure and the need for an alarm system for residents I ivlng near the river,downstream of the project,was suggested. 3.One participant suggested land use restrictions in the areas that could be affected by flooding in case of dam failure. 4.Severa!participants commented on the need for policies that would encourage local hire at the community level.Suggestions Included requiring unions to enroll workers from rural areas,use of tax pol icies,and review of NANA Corporation's local hire requirements at the Red Dog mining project. 5.It was requested that more discussion of the possible magnitude and signifIcance of people that wil I come from other areas of the country,without fInding work on the project.be provided.It was stressed that this could change the magnItude of Impacts significantly. 6.A table listing the varIous assumptIons regarding the origin and characteristIcs of the construction work force was recommended. 7.One participant commented that the assumption that 50 percent of the workers whose Jobs are terminated upon completIon of Watana will remain In the area may be too high.He cited the small economic base and resultant lack of Job opportunities In the smal I communities as the reason. 8.One participant asked about the possible access of local planners to the study team's socioeconomic Impact model. 9.It was asked whether cumulative Impacts that Included other projects In the Impact area were taken into account. 10.Several questions were asked and Issues were raIsed concernIng the work camps/vii lage Including:a)who pays for the camp;b)whether the workers would pay rent;c)the concerns of the Mat-Su Borough and individual communitIes;d)the degree of access;and e)the Implications of the camps on land use In the Upper Susltna Basin. 1 - 11.A discussion of the objectives of the mitigation process occurred. Several participants emphasized the need for a continuing mitigation process that wll I anticipate Impacts and Initiate measures to mitigate impacts before they occur,In which other agencies be Included. 12.One participant suggested additional clarification be put into the section concerning the ongoing studies on impacts to fish and wildlife user groups. 13.It was suggested that more research be con~ucted on part-time and subs I stence use of resources In the I mpact area.Another part ic I pant commented on the need to Include discussion of subsistence consIderatIons In Section 810 of ANCSA. 14.Additional use of resources on prIvate land by indivIduals gaining access wIth the projects's access road was mentioned as a possible adverse Impact that should be monitored and mitigated. 15.Additional use of aircraft to transport workers was mentioned as a possible mitIgation tool. 16.It was commented that ranges of population influx,or some form of confidence levels associated with the projections,would make the discussion of Impacts more useful to the communities.Threshold levels of populatIon Influx that would spur the need for new public facil itles were also suggested. 2 Inc. Inc. Inc. Randy Cowart AI Carson Ron Stanek Kevin Young Robed Mohn Herbert Smelcer S.O.Simmons Ed Busch Ken Hunt Bruce Bedard Robert M.Er,lckson Charlotte Thomas Nancy Blunck Jim Richardson Peter Rogers Rob In Hi II LIST Of PARTICIPANTS SOCIOECONOMfC IMPACT WORKSHOP NOVEMBER 30,1982 AGENCY ADNR,Research and Development Alaska Dept.of Natural Resources Alaska Dept.of Community and Regional AHa irs Acres American Alaska Power Authority Ahtna,Inc. Harza-Ebasco ADCRA Anc.,Div.of Community Planning Alaska Dept.of Natural Resources,Water Mgmt. Alaska Power Authority EDAW,Jnc. Alaska Power Authority Alaska Power Authority Frank Orth &Associates, Frank Orth &Associ ates, Frank Orth &Associates, 3 - CULTURAL RESOURCES MEETING Anchorage Holiday Inn November 30,1982 Subject:Mitigation Planning for Sus'ltna Pl:Irpose:To neyjew research design and methodology used in 1980-82 work. To review and discuss draft FERC License Appl ication. To discuss cost effective means by which the initial survey may be completed. To seek approval from the SHPO on the overall mitigation approach. In Attendance:Beth Walton,State Archeologist,Bureau of Land Management Diana Riggs,Department Natural Resources Tim Smith,State Office of History and Archeology Floyd Sharrock,Chief Archeologist,National Park Service George Smith,Project Leader,University of Alaska Museum E.James Dixon,Curator of Archeology,University of Alaska Museum Richard fleming,Alaska Power Authority Don Follows,Acres American,Incorporated Guests:Phil Hoover,Acres American,Incorporated Jack lobdell,Consultant The Cultural Resources Program Manager,Don Follows,opened the meeting at 9:10 a.m.in Room 227 of the Holiday Inn,Anchorage.After the introductions, the point was made how critical the cultural resources are to the hydroelectric project schedule.Compliance with Section 106 of the Historic Preservation Act of 1966,Executive Order 11593 and Title 36,Part 800,Code of Federal Regu- lations and related laws direct the process for Cultural Resources investiga- tion and mitigation planning. Dr.Dixon presented a synopsis of the field work which has been completed and reported on over the past three field seasons.To date,about 50 percent of the total ~roject area has been surveyed.Of special interest is the location of four tephras which provide dating references for the artifacts recovered.It is hoped that the cultural chronology of the region can be, for the first time,established. Dr.Dixon explained that in his approach to mitigation planning the term "po tent;a1 impacts II had been devel oped to a,ddress those sites outside the adversely effected areas.This third category allows for a more flexible means by which to address the large number of sites recorded (167)to date, many of which will not be impacted directly,and only P9tentially in the future.Potenti.al1y~impacted sites would not require systematic testing at this time,but should be monitored from time to time by the appropriate CULTURAL RESOURCES - 2 land managers to determine conditions.If conditions warrant,mitigation would then be required. Dr.Sharrock (NPS)asked at what point the Advisory Council on Historic Preservation should become involved in the project.The information that both Acres and the Power Authority had received in separate meetings with FERC in Washington,D.C.was that FERC would not contact the council until the basic reconnaissance was completed. Serious scheduling problems could arise ifFERC requires the Cultural Resources field survey to be completed next summer.The Alaska summer is only two and a half months long.The project size and remoteness introduce unique conditions under which a large workforce can become less efficient because of support logistics required.Based on his many years of Alaska experience,Dr.Dixon felt it would be unrealistic to expect completion in one year.It was the group consensus that two years would be best. Another significant factor in attempting to complete the work in one field season is the Alaska Power Authority fiscal year which begins July 1.Unless funds are available at present time to launch the spring 1983 workforce, the goal will be difficult to attain because of the University·s administrative procedural delays in hiring employees.. Dr.Fleming said that a decision on whether to proceed with a one or two year program will be made by the end of January,1983. In summary,the group consensus seemed to favor a two year survey program as outlined in the mitigation plan,and the early (if possible)involvement of the Advisory Council on Historic Preservation so that procedures can be established which satisfy both the FERC scheduling concerns and the Advisory Council . Phil Hoover will meet with F£RC the end of December to discuss the involve- ment of the Advisory Council. '0"" ,~ LAND USE Questions &Comments 1.CIRI and the village corporations asked that the Power Authority request that DNR identify lands suitable for exchange.They feel that land exchange with the state may offer one mechanism for the Power Authority to acquire project lands from them.Potential lands for exchange are becomm"ing limited.DNR has not commenced such a study. 2.Clarification was requested on the content of Section 24 of the Federal Power Act. 3.Discussion occurred regarding induced land ~se changes on Native corporation owned land resulting in public pressure to provide increased access,e.g.:potential of fishermen wanting improved access to Portage Creek.Natives are concerned that the project not lead to trespass on their lands. 4.Concern was expressed about the compatability of the proposed access plan with the Denali Scenic Highway plan. -Discussion related to potential recommendations of the ongoing study. The report on Denali Scenic Highway will need to be adopted by the Land Use Council before being released.As identified by BLM,the only incompatability with the Denali scenic Highway would be temporary transmission going into the Watana site. 5.It was suggested that an assessment should be conducted on the long term economics value of having a more appealing access road. 6.A suggestion was made that a land use committee be established.The potential of having the Power Authority participate on the Mat Su land use planning team was discussed as an option. 7.A request was made that a substation and distribution be located at Cantwell as part of supplying construction power to the site,and thus make Intertie power available to that community. 8.It was suggested that additional assessment of land use changes at the community level will be undertaken,particularly with respect to Cantwe 11. 9.It was mentioned that Native concerns should be presented in the FERC license application. 10.The Native corporations will not initiate planning until definite project requirements are received. 11.The Native corporations propose the following methods for the Power Authority t9 acquire project lands:purchase,lease or exchange. 12.Effects of land acquisition procedures on land use development were di scus'sed. ATTENDANCE LIST Land Use Workshop Tuesday,11/30/82 Charlotte Thomas Robin Hill Ron Stanek Herb Smelcer Bruce Bedard Steve Simmons Nancy Blunck Randy Cowa rt Robert Erickson Dave Tremont Pri sci 11 a Lukens Kevin Young Alaska Power Authority Frank Orth &Associates Alaska Dept.Fish &Game AHrNA Illc. Alaska Power Authority Harza-Ebasco Alaska Power Authority ADNR-R&D EDAW,Inc. Alaska Dept.of Community &Regional Affairs Acres American Acres American r·-- COMMENTS RECEIVED WORKSHOP ON RECREATION December 1,1982 1.Questions were asked regarding FERC policy on location of facilities off-site.When recreation resources are off-site or when there are problems developing the res~rvoir,FERC has.accepted developJT\ent of off-site facilities.State Parks concurs with this position agreement. "'.., The Power Authority stated their position is to a)take advantage of project facilities (roads &reservoirs),b)be responsive to landowners concerns (avoid trespass),c)direct use away from sensitive fish, wildlife and archaeologic resources. 2.Why is an expansion of Brushkana campground recommended?The need has been discussed already by BLM and it appears in their management plan. The project would increase demand for camping along the Denali Highway and this is a logical location.It would also keep some auto traffic and camping from penetrating the project area.BLM wou ld manage the area,and.BLM and Power Authority would enter into a memorandum of understanding regardi ng construct i on,operati on and maintenance. 3.State Parks Department is pleased with the plan as presented and confirmed that the plan is in agreement with the state-wide recreation plan.DNR supports the plan. State Division of Parks will open a new trail along Curry Ridge line, from Coal Creek to Troub lesome Creek,in 1983.They wou ld li ke.the Power Authority to consider adding threewhistlestops,consisting of small campsites and possibly shelter cabins,at Gold Creek,Curry Ridge and Indian River. 4.Question:Isa·full range of recreation facilities provided at Watana Village and are facilities provided for other than rugged hikersJ Answer -Power Authority:Yes,extensive recreation facilities and activities are included in the plan for the village.There is a full range of recreation opportunities provided in the recreation plan,from driving and pull-offs along the road,to a visitor center with educational exhbits,to rugged hiking. 5.Question:There are no improved trails in Denali National Park.Why does State Parks want improved trails? Answer -State Parks:Brushing out and hardening is done only where necessary (e.g.,inc lose-in forested areas).In further out open areas,rock cairns may be all that is necessary. 6.Concern was mentioned about Caribou kills on the Watana access road. The reports recommends lower design speed and lower profile for that road (Section 8,Aesthetics).Caribou kills are not known to be a COMMENTS RECEIVED WORKSHOP ON RECREATION - 2 problem on the Denali Highway now.The Denali Highway presently has an AADT of 50 vehicles;Parks Highway~200.The project is projecting 20 truck trips/day.While no firm traffic projections on the Denali access road are available,it will be much lower than the Parks Highway today and lower than the Denali Highway at that time.Recreation traffic will be limited primarily to July,August and September. 7.Question:Are any facilities proposed adjacent to the Watana access road? Answer:In addition to the turn-outs and trailheads shown on the project maps,rehabilitation of borrow areas for camping is a "Phase 5" item.They cannot be located at this time because the loation of borrow areas is not know.A note to this effect will be added to the map of recreation facilities. 8.Question:Why do we assume that demand will build up over time and not be instantaneous when the facilities open (p E-7-42)? Answer:National Park Service experience has shown this to be the case,even in well-known recreation areas.It takes time to build a sustained marked.If a new salmon fishing area close to Anchorage were opened,it would get immediate heavy use.Project facilities will not be that type of area. 9.Demand figures were discussed and agreed with;if anything,they may be high.This is why some facilities have been put in Phase 5. 10.What is the capacity of the Susitna River Boat Launch?6 vehicle places.This will be checked against DOTls Denali Highway Study. 11.Three facilities require Native concurrence -the Chulitna trail,Fog Lakes trail and campground,and Stephan Lake trail. Question:Is there a statement that says land acquisition costs will be in addition? Answer:Yes.The plan also recognizes that additional private recreation development may take place on private land. 12.The plan should mention that snowmobiling will probably increase along the Denali Highway.No specific areas need to be set aside. 13.Page E-7-39,paragraph 3 states fishing is decreasing.The data source should be re-checked to confirm this. 14.Capital investments will be part of Power Authority project financing. Operational costs will be partly done as part of regular operations. MOUls with the agency would detail arrangements. 15.Effects on downstream recreation appear to be mixed.Water quality will improve but quantity will decrease during the open water season. See Chapter 2 -Water Quantity and Quality. ItwWA .... - .... ATTENDANCE LIST WORKSHOP ON RECREATION December 1,1982 Larry Wright,USNPS Randy Cowart,ADNR Gary Stackhouse,USFWS Dave Dapkus,USBLM Mike Mills,ADF&G Roland Shanks,CIRl Jack Wiles,ADNR Richard Fleming,APA Bruce Bedard,APA Nancy Blunck,APA Gary Lawley,Harza-Ebasco Jack Robinson,Harza-Ebasco Peter Rogers,Frank Orth &Associates Robin Hill,Frank Orth &Associates Bob Erickson,EDAW,Inc. Jim Chappell,EDAW,Inc. Kevin Young,ACRES Priscilla Lukens,ACRES COMMEMTS RECEIVED Workshop on Aesthetics December 1,1982 1.Be sure that discussion of Watana access road clearly states EDAW·s recommended restudy of that alignment. 2.It was suggested that a mitigation measure be to take a film of the river from Tyone River to Gold Creek today,and again periodically after construction,in a "time-lapse"fashion. 3.Discussions of the construction camps and the townsite took place,with agreement that additional location studies and design studies are requ ired. 4.Discussions of the transmission lines took place,with agreement the north and south stubs need additional location studies but the line from the powerhouses to the intertie is well located.(The alignment between Watana and Gold Creek which was assessed in the application and discussed at the workshop was subsequently relocated to provide improved access for construction and operation.) - ATTENDANCE LIST WORKSHOP ON AESTHETICS December 1,1982 Larry Wright,USNPS Randy Cowart,ADNR Gary Stackhouse,USFWS Roland Shanks,CIRI Jack Wiles,ADNR Bruce Bedard,APA Nancy Blunck,APA Bob Erickson,EDAW,Inc. Jim Chappell,EDAW,Inc. SYPNOSIS OF AGENCY COl'iIMENTS AND QUESTIONS REVIEW OF DRAFT EXHIBIT E OF FERC LICENSE APPLICATION WILDLIFE AND BOTANICAL RESOURCES GROUP Tuesday,November 30,1982 Room 225,Holiday Inn,Anchorage ATTENDEES Name Lee Adler (LA) Roseann Densmore (RD) Bob Everitt (BE) Randy Fairbanks (RF) Steve Fancy (SF) Michael Grubb (MG) Gary Liepitz (GL) Ann Rappoport (AR) Martha Raynolds (MR) Karl Schneider (KS) Robert Sener (RS) Gary Stackhouse (GS) Judy Zimicki (JZ) Organization Ahtna Envirosphere ESSA Ltd. Envirosphere LGL Alaska Acres American ADF&G FWS LGL Alaska ADF&G LGL Alaska FWS No.Ak.Environ.Ctr. Address Box 6 Copper Ctr. Anchorage Vancouver,B.C. Seattle Fairbanks Buff a10 Anchorage Anchorage Anchorage Anchorage Anchorage Anchorage Anchorage Phone No. 822-3476 277-1561 604-872-0691 206-451-4620 479-2669 716-853-7525 344-0541x281 271-4575 274-5714 344-0541 274-5714 263-3475 277 -2134 Discussion of Preparation of Exhibit E:Baseline Description,Impact Section and Mitigation Section. KS -What will the February and June submittals entail? What data will be in which document? Discussion of Schedule for Submitting Documents and Agency Review Procedures. AR -What about after June 30?Will there be continuing studies? When will those data be incorporated? Discussion of Schedule after June 1983.Discussion of Baseline Vegetation Description. LA -Is the Susitna basin key winter moose range? Discussion of Areas That Might be Critical During a Severe Winter. AR -Is a new classification system being used to'help characterize moose habitat? - -~ WILDLIFE AND BOTANICAL RESOURCES GROUP - 2 Discussion of Viereck &Dyrness System and Relation to Moose Browse Identification. RF -Was all vegetation mapping described in Exhibit Edone from 1:120,000 1980 U2 photography? AR -Does Exhibit E conta-in all work completed up to this point,so that new data will go into the June 30 document? Discussion of Threatened or Endangered Wildlife Species,Prioritization of Species,Moose Baseline Description. KS -New census this fall showed more moose on the Sus itna Riv.er downstream of Devil Canyon than have ever been measured there before. Discusion of .Moose Calving,Food Habits and Mortality. KS -Black bear predation on moose calves is important as well as brown bear predation.Early green-up of vegetation in the river valley may be important to cows th,at are about to calve,even if the area is not a true winter range. Discussion of the Caribou in the Area,and Dall Sheep. KS -Sheep sighted in the Watana Mountain -Grebe Mountain area are probably a sub-group of the main Ta-Ikeetna Mountai.ns group.The number within the Susitna watershed could vary. Discussion of Brown Bear Baseline Description. KS -Yes,one would expect brown bear population to decrease downriver due to poorer habitat and lower elevation. Discussion of Black Bear,Wolves,Coyotes,Wolverine,Belukha. KS -Belukha feed on anadromous fish.Smelt runs in Cook Inlet are also an important food source.Have they been studied? Discussion of Furbearer,Bird and Small Mammal Baseline Descriptions. AR -What is your perception of the completeness of the baseline information? AR -How about information on population increases or decreases,or the quality of the habitat?Are there any gaps in that type of information?Are the data being gathered?When will they be available? WILDLIFE AND BOTANICAL RESOURCES GROUP - 3 Discussion of Data Gaps and 1983 Field Season. KS - I hope we can get the 1983 field program set up this winter.All issues should be identified. AR -1 1 m glad to see the vegetation mapping is being re-done and that you (LGL)are not just accepting the inadequacy of the earlier data. Will the original researchers (principal investigators)be given the new vegetation maps to re-work their data? Discussion of Importance of Early Planning,ExpecialTy if This is a Severe Winter.Discussion of Impacts to Moose Due to Watana Development. AR -Hunting regulations are political,and these are not predictable. Unless commitments are actually a part of the license,they will not necessarily be followed. KS -Project personnel are easier to regulate than the public.Many different regulatory options are available.Permitting to restrict harvest is easier than closing the road. Discussion of License Application Approach to Issues Outside the Power Authority's Jurisdiction. LA -Has any consideration been given to regulations Natives may impose? They can control access -trespass -but can't directly regulate hunting. Discussion of Moose Impacts and Moose Browse Studies. AR -Both summer and winter vegetation sampling will be needed to accurately determine energy and protein content of browse. Discussion of Planned Moose Studies and Those in Progress. AR -The document (Exhibit E)should clearly describe any work that is going to be done,and its schedule. Discussion of Species Prioritization and Mitigation Tradeoffs. KS -In many cases,compensation may be the major mitigative technique. ,W2. - ,~ WILDLIFE AfIlD BOTANICAL RESOURCES GROUP -4 Discussion of Impacts to Downstream Moose and Caribou. RF -How is FERC going to respond to the lack of specificity in the caribou impact and mitigation section? KS -The effects on caribou are difficu It to mitigate except through the no project 0ption.Out-of-kind mitigation wi 11 be determined after impacts have been assessed during construction and operation. Discussion of Impacts to Dall Sheep. KS -Might be useful to do a slope stability study of Jay Creek sheep lick. Inundation might even enhance the lick through erosion exposing fresh mineral soil. Discussion of Impacts to Brown Bear and Black Bear. KS -Both bear species use several different,scattered food sources,which wi 11 be more or less important indifferent years.Pinpointing the factor limitin9 bear populations is difficult,consequently the effect of the dams is difficult to predict. Discussion of Impacts to Wolves of Watana Development. KS -Activity sensors on wolves showed that helicopters caused reactions,but the wolves,even one in a den with pups,oecame habituated.Good data are available on the optimum time of day and season to minimize disturbance. Discussion of Impacts on Wolverine,Belukha,Beaver,Marten,Raptor, Waterfowl,and Small Mammals. AR -Looking at the project as a whole,is diversity being maintained through mitigation or are moose being favored to the neglect of other species? In some areas,different species may be more important than moose. Discussion of the Impacts of Devil Canyon and the Access Roads. AR -Are there any plans to quantify the impact of different alternative cons truct i on methods? Discussion of FERC'sRequest to Emphasize Commitments Ove!r Options and Recommendations in the license Application. KS -If the project is not clearly defined,with the associated impacts of each decision,then reviewing the project is difficu It. WILDLIFE AND BOTANICAL RESOURCES GROUP - 5 AR -The construction method with the least impact should be strongly supported. GS -Are the costs of the different options included? Ar -Exhibit E should contain a table of project impacts and corresponding mitigation measures.All project aspects should be presented and evaluated. GS -It is important for the groups to keep up with any changes. KS -Is there any mechanism to let agencies know of any changes? Discussion of Decision Making Process. AR -What was the level of communication during the engineering design? Discussion of Formal and Informal Interactions. GS -Access route has potentially severe impacts.Strong recommendation may be made to FERC to change it.The road between the dams might change, too,due to Native bargaining. Discussion of the Impact of the Access Roads. KS -There is not a direct relationship between caribou herd size and range size.Management goals for the Nelchina herd are now +20,000,but that could change.Changes in potential caribou habitat are important,even if the population is not immediately affected.70,000 is too high a population for that herd caused a crash,however a higher ceiling is being considered,30,000 -40,000.You should aSSI.Jme an eventual population of 40,000. LA -The population is presently increasing and will continue to increase unless there is some regulatory change. KS -When access increases,hunting demand will increase. Further Discussion of Access Road and Traffic Patterns. KS -Traffic data averaged over a year is not good enough.It is important to know about peak traffic flows -when they occur and what the maximum number of vehicles would be.The impact on animals depends on the time of year. GS -We need clear traffic data to be able to estimate impacts. KS -The time of day of peak traffic might be more important than the time of year. WILDLIFE AND BOTANICAL RESOURCES GROUP - 6 AR -Suggestions aren't being followed in the Terror Lake project.Need to tie mitigation down,be specific. KS -We should request some socioeconomic data on traffic predictions. Discussion of Impacts of Railroad Traffic. KS -Trains should be scheduled to miriimize moose encounters.Scheduling trains close together and using longer trains would also minimize encounters. GL -Have the effects of the access road mentioned earlier -roadside dust, ATV use -been quantified in terms of loss of habitat or an-imals? RF -Roadside dust could actually be beneficial~causing earlier melting and thus early browse. KS -Impacts should be examined to determine if their effects are si gnifi cant. Discussion of Mitigation Measures for Borrow Sites,Access Roads, Transmission Corridors. AR -Do Exhibit E transmission corridor studies include the intertie? Helicopter construction was agreed to on some sections,but then maintenance was not going to be done by helicopter.The result was less ~helicopter use. MG -How do these issues get dropped through the cr~cks? AR The decisions are not written down.If it is written in the permit, then it happens.But if only recommendations are made,then they aren't always fo 11 owed • Discussion of Areas of Uncertainty. AR -Gray areas (where changes are possible)should be identified,so that if things change we have some idea of the impacts of the new option. Construction bids should include all details to make sure the stipulations don't get forgotten. Discussion of Actions Outside Power Authority Jurisdiction. LA -Ahtna has no plans to develop project area land if Susitna is built - there is no cash incentive. WILDLIFE AND BOTANICAL RESOURCES GROUP - 7 Discussion of Plan for Periodic Spring Floods. AR -Has the plan for 30,000 cfs spring floods been discussed with the aquatic group? KS -How about the legal effect of causing destruction of property? Discussion of Negotiations Required for Compensatory Mitigation Measures. KS -Enhancement of moose habitat is possib le,but some impacts cannot be mitigated.Quantification of impacts is perhaps not too important in these cases.General enhancement actions could be taken to preserve the quality of the area (Le.preserve Stephan Lake area from development). Discussion of Monitoring Programs. KS -the cost of mitigation options is difficult to estimate.There may be some trading of State land,and some outright purchase. REVIEW OF DRAFT EXHIBIT E OF FERC LICENSE APPLICATION WILDLIFE AND BOTANICAL RESOURCES GROUP Tuesday,November 30,1982 Room 225,Holiday Inn,Anchorage -ATTENDEES ~, Name Lee Adler (LA) Roseann Densmore (RD) Bob Ever i tt (BE ) Randy Fairbanks (RF) Steve Fancy (SF) Michael Grubb (MG) Gary Liepitz (GL) Ann Rappoport (AR) Martha Rayno 1ds (MR) Karl Schneider (KS) Robert Sener (RS) Gary Stackhouse (GS) Judy limi cki (JZ) Organization Ahtna Env irosphere ESSA Ltd. Envirosphere LGL Alaska Acres American ADF&G FWS LGL Alaska ADF&G LGL Alaska FWS No.Ak.Environ.Ctr. Address Box 6 Copper Ctr. Anchorage Vancouver,B.C. Seattle Fairbanks Buffalo Anchorage Anchorage Anchorage Anchorage Anchorage Anchorage Anchorage Phone No. 822-3476 277-1561 604-872-0691 206-451-4620 479-2669 716-853-7525 344-0541x281 271-4575 274-5714 344-0541 274-5714 263-3475 277 -2134 RS began the meeting with a description of th~preparation of the Wildlife and Botanical Resources sections of Exh-ibit E.Research reports from ADF&G and the Uni vers ity of Alaska prov ided much of the data for the basel i ne description.These data were substantially supplemented with a thorough literature review.The impact section was prepared in a mann~r consistent with the Susitna Project Fish and Wildlife Mitigation Policy.Impacts were prioritized by: 1)percent of population affected; 2)certainty of impact occurring;and 3)severity of impact. The mitigation section is still in progress. Sf Following FERC I S request,the impact section assumed normal eng.ineering practices with no special mitigation measures. RS -Continued his description of the mitigation section. KS -What do the February and June submittals entail? John Hayden (JH)entered,and the question was deferred to him. JH -We expect feedback from FERC on December 28,which wi 11 resu lt in correction of the document before the F ebru ary submittal.FERC wi 11 WILDLIFE AND BOTANICAL RESOURCES GROUP - 2 have a 60-d ay revi ew peri od,then any further requ i rements can be addressed by June 30.We have 90 days to respond to FERC's request for improvements.The June 30 document will be a response to FERC's evaluation,not a total re-write of Exhibit E. AR -How about after June 30?Will there be continuing studies? JH -After June 30,FERC hopes to have enough data to be able to start an EIS.FERC will then incorporate 1983 data as they come in from fisheries,wildlife,and archeological studies.Approval could be contingent on certain aspects of 1983 field data.Not until the EIS is prepared will the agencies have an official comment time,probably in fall 1983. SF began the presentation of the baseline descriptions.He emphasized the draft nature of the document,particularly the literature cited,the tables and figures,and the mitigation section.An effort was made to be comprehensive and supply all the background material that the reviewing agencies would need. No endangered plant species were found.Vegetation maps are inaccurate,and will be re-done with a more detailed classification system (still Viereck and Dyrness)and large scale imagery. LA -Is the Susitna Basin key winter moose range? SF -Yes,particularly when the snow is deep.Sampling revealed 20% utilization of browse.This winter might reveal browsing patterns in severe wi nters. AR -Is a new classification system being used to help characterize moose hab it at ? SF -No,still Viereck and Dyrness,but past Level 3 to subcategories.The goal is to stratify browse so that heavy and light browse areas can be separated. RF -Was all vegetation mapping described in Exhibit E done from 1:120,000 1980 U2 photography? SF -Yes. AR -Does Exhibit E contain all work completed up to this point,so that new data will go into the June 30 document? RS -Yes.We will indicate work in progress if it is not complete. - - WILDLIFE AND BOTANICAL RESOURCES GROUP - 3 SF Described the ground truth data available.No endangered wildlife species were found except 2 transient peregrine falcons sighted in 1974. Prioritization of species:1)moose,2)caribou,3)brown bear~4)black bear,5)other big game~6)furbearers,7)raptors,8)waterfowl~and 9) other birds and small mammals.Moose in the middle basin were studied separately from moose along the downstream floodplain. KS -New census this full showed more moose in the Susitna River downstream of Devil Canyon than have ever been measured there before. SF described moose calving areas,food habits,and mortality.A strong relationship was found between calf mortality anu snow depth.Brown bear predation was also important. KS -Black bear predation is important as well.Early green-up of vegetation in the river valley may be important to cows that are about to calve, even if the area is not a true winter range. SF discussed the Nelchina Caribou Herd~its present and historical size and range,traditional calving areas,and its subgroups.He then described Dall sheep in the project area. KS -Sheep sighted in the Watana Mountain -Grebe Mountain area are probably a subgroup of the main Ta"lkeetna Mountains group.The number within the Susitna watershed could vary. SF discussed brown bear,their denning habits,food sources,density estimates for the impoundment areas and downstream. KS -Yes,one would expect brown bear populations to decrease downstream due to poorer habitat and lower elevation. SF discussed brown bear productivity and hunter harvest.He then discussed _black bears~their distribution,denning habits,food sources~and mortality. He further described the wolf packs of the middle Susitna basin~the lack of coyotes, the ranges and densities of wolverine,and the studies of belukhas in Cook Inlet. KS -Belukhas feed on anadromous fish.Smelt runs in Cook Inlet are also an important food source.Have they been studied? 15 Minute Break SF continued his presentation with the baseline descriptions of beaver, muskrat,marten,red fox~lynx,coyote,and weasels.He then described the field work that has been done to characterize birds in the project area 135 species were recorded in the middle basin,including,in 1981,active nests of 6 golden eagles~5 bald eagles,1 gyrfalcon,2 goshawks,and many raven.Relatively low numbers of waterfowl were found in the middle basin. WILDLIFE AND BOTANICAL RESOURCES GROUP - 4 The data from these years of small mammal trapping were used to characterize these species. AR -What is your perception of the completeness of the baseline information? How about information on population increases or decreases,or the quality of the habitat? SF -Much of that information is included in Exhibit E. AR -Are there any gaps in that type of information?Are the data being gathered?When will they be available? SF -Yes,some gaps have been identified. RS -We are still trying to determine which gaps are most important and design the 1983 field season around these data needs.We have made preliminary recommendations to the Power Authority,but the actual program is still being worked out. SF -We are expecting input from USFWS and other investigators. RS -Technical meetings between now and December 6 should also provide some input. SF -Ann,do you have any particular data gaps in mind? AR -No,since 1 haven't had time to read Chapter 3 yet,1 don't know what's already covered. KS -1 hope we can get the 1983 field program set up this winter.All issues should be identified. AR -1 1 m glad to see the vegetation mapping is being re-done and that you are not just accepting the inadequacy of the earlier data. SF -The new vegetation maps will change some of the wildlife population estimates that are based on densities. AR -Will the original researchers (principal investigators)be given the new vegetation maps to rework their data? SF -All the data will be reworked,but not necessarily by the original researchers.The new vegetation maps will be digitized. RS -Early planning for field studies will be important,especially if this is the severe wi nter we have a 11 been waiting for.We need a contingency plan to see where the moose are during a severe winter,and to conduct early spring vegetation studies to check the importance of green-up for moose. ~.WILDLIFE AND BOTANICAL RESOURCES GROUP - 5 .~AR -Are there any bear studies being planned? SF -Yes,but those studies will be done in August,so there's more time for planning. SF then began a description of the impacts of Watana development on moose. Prioritized impacts included:1)permanent loss of habitat,2)blockage of movement,3)disturbance,4)accidental mortality,5)alteration of habitat, and 6)increased hunting mortality. - ~, - AR -Hunting regulations are political,and thus are not predictable.Unless recommendations are actually part of the license,they will not necessarily be followed. KS -Project personnel are easier to regulate than the public~Many different regulatory options are available.Permitting to restrict harvest is easier than closing the road. RS -The license application can state what the Power Authority will do,but can only state options for issues under ADF&G jurisdiction. LA -Has any consideration been given to regulations that Native corporations may impose?They can control access -trespass -but can't directly regulate hunting. RS -This is another issue that is not directly under Power Authority jurisdiction.We are not presently planning to discuss options open to private landowners. SF resumed the discussion of moose impact.Two approaches are being used to predict impacts to moose:a population based assessment,and a habitat based energetics model.To determine the quality of moose habitat,energy and protein content of browse must be known.Vertical distribution of browse, and consequently the amount available at different snow depths,is also important.In order to get this data,trial moose browse sampling studies will be conducted in the field next summer and the vegetation of the area wi 11 be re-mapped to identify variation in moose browse potential. AR -Both summer and winter vegetation sampling will be necessary to accurately determine energy and protein content of browse. SF agreed,though most work wou ld have to be done in the summer when the whole plant was available for sampling;some sampling would have to be done in the winter.Brown bear predation and critical winters are probably two factors limiting moose population.A large browse sampling program is planned for the summer of 1984,the data will be worked up that fall,then mode 11 i ng wi 11 be done the next spri ng (1985). WILDLIFE AND BOTANICAL RESOURCES GROUP - 6 AR -The document (Exhibit E)should clearly describe any work that is going to be done,and its schedule. SF -We are also working on mitigation and enhancement techniques,and identifying candidate areas. KS -Compensation may be the main mitigative technique for moose. SF described impacts to downstream moose.Changes in vegetation succession should favor moose during the license period.Frozen condensation on vegetation due to open water could reduce browse availability.Open water could cause changes in plant phenology and will act as a barrier to moose movements. Although caribou are excellent swimmers,the impoundment may influence their movements,as may ice shelving and drifted snow.Long-term monitoring programs will be necessary to determine impacts. RF -How is FERC going to respond to this lack of specificity with respect to caribou? KS -These types of impacts are difficult to mitigate except through the no project option.Out-of-kind mitigation will be discussed after the impacts have been assessed during construction and operation. RS -FERC realizes the limitations of biological prediction and would prefer no numbers to unreliable numbers.Indicating that further investigations will be done is acceptable,if sufficient detail is provided. SF discussed the impact of borrow areas on caribou,then went on to Dall sheep.The two major impacts on Dall sheep are:1)aircraft disturbance, and 2)inundation of 20-40%of Jay Creek mineral lick.The consequences of the inundation of the lick are not certain. KS -It might be useful to do some slope stability studies of the lick. Inundation might even enhance it through erosion exposing fresh mineral SO"j 1• 30 Minute Lunch Break SF continued the description of impacts likely to result from Watana development.There will be no poplation effects on brown bear due to facilities or borrow areas.However,the impoundment might alter movement patterns.Any mitigation measures to enhance brown bear populations will conflict with moose mitigation since brown bears are their predators. The resident bear black bear population in the Watana area could be eliminated due to the inundation of den sites.The transient black bear -- ,... WILDLIFE AND BOTANICAL RESOURCES GROUP - 7 popu lation might be affected by decreases in salmon runs. KS -Both bear species use several different,scattered food sources which will be more or less important in different years.Pinpointing the factor limiting bear populations is difficult,consequently the effect of the dam is difficult to predict. SF -No known wolf dens or rendezvous sites will be flooded.Disturbance during the denning season could cause increased pup mortality. KS -Activity sensors on wolves showed that heli~opters caused reactions,but the wolves,even one in a den with pups,become habituated.Good data are available on the optimum time of day and season to minimize disturbance. SF -Human harvest of wolves seems to be the limiting factor,not food supply.The same is true of wolverines. Impacts on belukha whales could occur through changes in water temperature on fish runs,as has been shown for the St.Lawrence River.Neither is expected to change detectably at the Sus itna mouth as a resu lt of the project.Bears are expected to benefit from downstream flow regulation.Marten will lose habitat and are also expected to suffer from increased trapping pressure. More precise data 'on the altitude of raptor nests is necessary to quantify impacts.Possible mitigation methods include:1)building new nest structures,2)moving nests,3)exposing new nesting rock by blasting,4) building artificial cliffs,or 5)topping trees to improve their nesting potential. Waterfowl should benefit from the increased open water.Other birds and small mammals will suffer from habitat loss.Some species will benefit from the mitigation measures proposed for moose. AR -Looking at the project as a whole,is wildlife diversity being maintained or are moose being favored to the neglect of other species? In some areas different species may be more important than moose. SF -Other species are being considered,but there has to be some prioritization of species. Impacts due to Devil Canyon are similar to those expected to result from Watana development,but generally less severe because of the smaller size of the impoundment and the steeper slopes of inundated terrain. Transmission line impacts will be minimized by constructing in the winter time or using helicopter support.Some trees will be cut,but brush will be left -no clear cutting. WILDLIFE AND BOTANICAL RESOURCES GROUP - 8 AR -Do you have any plans to quantify the impacts of different a lternat i ve construction methods? RS -No,Chapter 3 is not supposed to review options,but rather to present the impacts of the chosen option. KS -If the project is not clearly defined,with the associated impacts of each decision,then reviewing the project is difficult. AR -The construction method with the least impact should be strongly supported. GS -Are the costs of different options included? AR -Exhibit E should contain a table of project impacts and corresponding mitigation measures.All project aspects should be presented and evaluated. GS -It is important for the reviewing groups to keep up with any changes. KS -Is there any mechanism to let agencies know of any change? RS -The Power Authority would do that.Decisions such as the access road design speed have been changed due to environmental involvement,and we have written Chapter 3 according to the new decision,but we haven't seen the maps from R&M incorporating that decision yet. AR -What was the level of communication during the engineering design? RS -We have had formal interaction by memorandum (RS passed around several examples),and also much informal communication in meetings with project engineers. GS -The access road has potentially severe impacts.A strong recommendation may be made to FERC to change it.The road between the dams mi ght change also,due to Native bargaining. RS -That would not be surprising,since the environmental issues really haven't changed.However,we are writing Exhibit E as if the decision on access was firm,and including mitigative measures relevant to the route in question. SF described the impacts of the access road including increassed hunting pressure,increased road mortality,increased disturbance,increased ATV use. KS -There is not a direct relationship between caribou herd size and range size.Management goals for the Nelchina herd are now +20,000,but that could change.Changes in potential caribou habitat are important,even if the population is not immediately affected.70,000 is too high a population for that herd,and historically caused a population crash. """I I ,~ WILDLIFE AND BOTANICAL RESOURCES GROUP - 9 However,a higher ceiling of 30,000 -40,000 is being considered and should be used for your planning .• LA -The population is presently increasing and will continue to increase unless there is some regulatory change. KS -When access increases,hunting demand will increase. SF described the potential effects of the access roads on caribou.Predicted road traffic levels are low:20-30 trucks/day. KS -Traffic data averaged over a year is not good enough.It is important to know about peak traffic flows:when they occur and what the maximum rtumber of vehicles would be.The i.mpact on animals depends on the time of year. GS -We need clean traffic data to be able to estimate impacts. KS -The time of day of peak traffic might be more important than the time of year. AR -Suggestions are not being followed in the Terror Lake project.We need to tie mitigation down,to be specific. KS -We should request some socioeconomic data on traffic predictions. AR -The access plan includes a railroad which will also have an effect on moose. SF -In Canada,plowing railroad tracks with a wide plow that left no berm did not decrease moose mortality.Eighty additional train cars per week will be travelling as a result of the project. KS -The trains should be scheduled to minimize moose encounters.Scheduling trains close together and using 10n9'er trains would also minimize encounters. GL -Have the effects of the access route mentioned earlier -roadside dust and ATV use -been quantified in terms of loss of habitat on animals? RF -Roadside dust could actually be beneficial,causing earlier melting,and thus early browse. KS -Impacts shou 1d be examined to see if theyt re significant. RS described in-kind mitigation.Borrow sites will be upland areas preferentially.First level terraces will be mined using drag1ines. Guidelines to minimize -impacts of borrow areas were described.Locations of borrow sites for Watana and Devil Canyon dams were also described. Guidelines for camp facilities,access roads,and transmission lines were reviewed. WILDLIFE AND BOTANICAL RESOURCES GROUP -10 AR -Do Exhibit E transmission corridor studies include the intertie? RS -Yes,but most of the data is from the Environmental Assessment Report prepared by Commonwealth Associates. AR -Helicopter construction was agreed to on some sections of the intertie, but then maintenance wasn't going to be done by helicopter.The result was less helicopter use. MG -How do these things get dropped through the cracks? AR -The decisions are not written down. JZ -It is not clear exactly when the decisions are made. AR -If a decision is written into the permit,then it will happen.But if only recomendations are made,they often aren't followed. RS -The scope of work for subcontractors has to be very detailed.Salary and schedule provisions should be established in the design consultants' contracts to facilitate their working as a team with the project environmental specialists.At present,a few gray areas still exist - the regulation of access by workers during construction,extent of clearing and helicopter support for building and maintaining the transmission corridor.But these are basically policy decisions. AR -These gray areas should be identified,so that if things change,we have some idea of the impacts of the new option.Construction bids should include all details to make sure the stipulations don't get forgotten. RS -So far we have only prepared guidelines,but our portion of the application assumes that they will be followed.There is an important need for consistency,to make sure the commitments are really acceptable to all parties,and are reflected in all sections of the license application. RS went over the list of environmental gUidelines,which are included as an appendix of Chapter 3 in Exhibit E.Management decisions by some organizations other than the Power Authority will have an effect on mitigation plans:ADF&G,USFWS,BLM,etc. LA -Ahtna has no plans to develop land if Susitna is built -there is no cash incentive. RS discussed the recreation plan developed by EDAW,which includes phased implementation,with interagency review and concurrence between phases.He described biological input to that plan. SF discussed ~sing periodic flood releases (30,000 cfs)to mitigate for maturation of downtream floodplain vegetation. - WILDLIFE AND BOTANICAL RESOURCES GROUP -11 AR Have these plans been discussed with the aquatic group? KS -How about the legal impacts of causing property destruction? SF -These questions and others such as candidate areas and alternative methods for habitat enhancement will all take lots of negotiation. Ideas such as controlled burning,irregular selective logging, vegetation crushing are all being considered. KS -Enhancement of moose habitat is possib le,but some impacts cannot be mitigated.Quantification of impacts is perhap~not too important in these cases.General enhancement actions could be taken to preseve the quality of the area,such as proserving Stephan Lake from development. RS -FERC is interested in the mitigation process that is being set up, including long-term monitoring studies.They want a description of the program,expected products,and the schedule. RF -1 1 m interested to learn specifics of what wi 11 be in the FERC license application,and FERC's response to non-specificity. RS -FERC wants a mitigation plan,not a plan for a plan.However,FERC realizes that some aspects of planning may be beyond the Power Authority's jurisdiction.They are also interested in cost estimates for the mitigation plan. KS -The cost of mitigation options is difficult to estimate.There may be some trading of State land,and some outright purchase of compensation lands. RS -Some measures are easier to assign a cost to,such as engineering design modifications,incinerators,and other points mentioned in the environmental guidelines.The cost of long-term compensatory measures is much more difficult to ascertain,especially since some decisions won't be made until later in the project. WETLANDS MEETING Thursday,December 2,1982 Holiday Inn,Anchorage,Alaska ATTENDEES Name Organization Address Phone No. Bruce Bedard (BB)Alaska Power Authority Anchorage 276-0001 Roseann Densmore (RD)Envirosphere Anchorage 277 -1561 Richard Fleming (RF)Alaska Power Authority Anchorage 276-0001 Chris Godfrey (CG)USCE Reg.Functions Anchorage 552-4942 Michael Grubb (MG)Acres American Inc.Buffalo 716-853-7525 Jon Hall (JH)USFWS,NWI Anchorage 263-3403 Priscilla Lukens (PL)Acres American Inc.Anchorage 276-4888 Dave McGillivary (OM)USFWS,Regional Office Anchorage 276-3800 Ann Rappoport (AR)USFWS,WAES Anchorage 271-4575 Martha Rayno 1ds (MR)LGL Alaska Anchorage 274-5714 Ted Rockwe 11 (TR)USCE Reg.Functions Anchorage 552-4942 Robert Sener (RS)LGL Alaska Anchorage 274-5714 Bill Steigers (BS)U of A,Ag.Exp.Sta.Palmer 745-3257 Judy Zimicki (JZ)No.Ak.Environmental Ctr.Anchorage 277-2134 RS introduced the meeting.He discussed the ambiguity of the wetlands classification system used in previous mapping.The goal of this meeting was to come up with a practical method of defining and mapping wetlands to facilitate USFWS review and Army Corps of Engineers (USeE)permitting under Section 404 of the Clean Water Act and possibly Section 10 of the Rivers and Harbors Act of 1899,and to aid faci lity siting.LGL is looking into the possibility of incorporating wetlands mapping as part of the vegetation re-mapping program. MR presented a summary of wetlands work that has been done to date.Some work was done to characterize aquatic vegetation of ponds in the project area.That work has been presented as part of Chapter 3 in Exhibit E. Wetlands mapping was done using the Cowardin classification system of the U.S.Fish and Wildlife Service (USFWS).Two sets of maps were produced. One,at a scale of 1:24,000,consists of 7 maps of the two impoundment areas. The other,a set of 3 maps at a scale of 1:63,000,mapped alternative access routes.Vegetation maps of the same scale were used as base maps.A system for converting Viereck and Dyrness vegetation classes to Cowardin vegetation classes was developed (see Table 46,Phase I Report,Plant Ecology).Using Cowardin's definition of wetlands,all wet herbaceous,all shrub,and all forest vegetation-types were mapped as potential wetlands.A subjective judgment of slope was made to eliminate steep,well-drained areas.No re-interpretation of the imagery or ground truthing was done. JH,when asked how USFWS maps wetlands,replied that they use aerial photography,following the Cowardin system,look for one of three characteristics:flooding,hydrophytes,or hydric soils. r i WEllANDS l"1EETING - 2 RF -According to Cowardin's definition then~wetlands were appropriately mapped for the Susitna Project. JH -Some plant species occur only in wetlands.Many~however,occur in both wetland and upland areas.Then you ha~e to look at the other criteria. RS -In order to identify procedures and criteria for wetland mapping,we need to know if the Corps accepts Cowardin for Section 404 permitting. TR -We accept and use Cowardin,.but it is not always sufficient for Section: 404 decisions.Often the USCE Jurisdictional boundaries are different from the wet 1and bound aries.The Nat iona 1 Wet 1anils Inventory (NWI)maps, are at a good sca le for 1arge proj ects.However,we often need soi 1 data because all three parameters (flooding,hydrophytes,and hydric soi 1)are necessary to def ine USCE wet lands.The Corps a 1so needs hydrologic data to know how a given wetland ties into the watershed. ~RF -The huge scale of the project area (over 60,000 acres)makes it difficult to map.How'much sampling would be necessary? TR -Sampling areas can be representative of other areas.l"1aps are only needed of impact areas:roads,borrow sites,camp sites~etc.No wetlands maps of the impoundment areas are needed. i""'"JH For USFWS ~you do need wet 1and maps of the impoundment area. RF -No need for soils maps of the impoundment. JH -Slopes should not be arbitrarily excluded from wetland categories. Larger scale color infra-red photography should have been used.In the Tanana River basin,USFWS is using the Viereck and Dyrness classification system and a wetlands modifier to map the area.The resulUng map is easy to convert to the Cowardin classification system. The water regime modifiers in Cowardin's system are especially useful to USCE. RS -Remapp i ng of veget.ati on wi 11 be done to Level 3 and beyond for moose browse vegetation types. ..... RF -For most areas~we have vegetation maps and slope is available from contour maps.Might ne~d more soil work • TR -Once we have maps of the vegetation,hydrology~and project impacts, wei 1'1 be able to·see where more data such;as soil types is:necessary. RS -Are.the so,i 1 par;>ameters lJSCE needs ava;lab le from engineering borings and soil pits? II II USCOE WETLANDS MEETING - 3 RF -Some soil maps exist)though I don't know their scale or adequacy. RS -The Soil Conservation Service has not mapped all of the Susitna area. Several questions still need to be answered: 1)Appropriate level of detail of vegetation mapping to be useful for wetlands classification? 2)What soil parameters are important to USCE? JH -Even Level 4 of the Viereck and Dyrness system doesnlt allow direct conversion to wetland categories.Often)other data are needed. TR -Ground truthing will be very IJseful.The USCE personnel who will be responsible for permitting should go along. RF -What time of year is best for ground truthing? TR -Anytime during the growing season. RS The people doing the vegetation mapping will be working on the ground truthing next summer. JH -With a group of people who are familiar with the area)we should be able to sit down with the USCE and a wetlands map and decide which areas need USCE permits and which areas are marginal and need ground-checking. RS -Is it proper procedure to involve USFWS and USCE in the preliminary process and ask you to review drafts? JH -lid be glad to work with you. TR -Yes)certainly)we prefer it that way. BB -Have you discussed the types of permits required?They are: Section 404 -all waters of the U.S. Section 10 -navigable waters -below Devil Canyon. U.S.Coast Guard -navigable waters -south of Portage Creek. TR -The USCE definition of navigable waters may not be the same as other agencies.If Section 10 jurisdiction hasn1t been taken yet by USCE) then it will not be. RS -We need to alter the approach to vegetation ~apping to be sure to distinguish wetlands.We may need to map more vegetation types beyond Leve 1 3. RF -Only -in .access and transmission corridors. j- WETLANDS MEETING - 4 RS -We can restrict the mapping to known corridors and impact zones.The major borrow areas for the dams have also been identified.The borrow .-areas for the access road have not been fi na 1i zed,but some potential borrow areas have been indicated. RF -Those potential borrow areas aren1t likely to chang~much. RS -What should be included in FERC application?I would suggest: 1)Wetland maps already prepared. 2)Discussion of their preparation and coverage. 3)Plans to rectify problems. 4)Revised maps coming later.(The new maps can be submitted as supplements when they are done). ~IH - I wou 1d be concerned about inc 1ud i ng the old maps. TR -Could you modify the old maps by double-checking them with some aerial photography? RF -Might be possible,but probably not by February 15. JH -It would only take 3-4 days to map wetlands in the whole area (impoundments only).The cartographic work,however,would take awhile. From the slides (John Hayden's talk on Monday),upland wetland areas looked fairly easy to define. RS -We want to confirm to FERC that we are handling wetlands thoroughly.We should list soil features that will be supplied to USCE. TR -USCE needs soil profiles,from the litter layer down to ground water, depth to ground water,chroma,mottling,gleying,soil type,location of soil pits.Primary interest is in the root zone,the top 18 11 -24 11 •We would be glad to work with any field personnel for a few days to explain the USCE requirements and sampling methods. TR - A few days work should give us a fairly good jurisdictional map. JH -The first step would be a wetlands map;regulatory wetlands will be a -subset of that. TR -Final CaE regulations are expected by December 15.Our jurisdiction cou ld change. DM -JH might be interested in talking to Dr.Talbot who did some vegetation sampling in the Susitna basin several years ago.,..,., _. WETLANDS MEETING - 5 AR - I would like to clarify the timing -the vegetation maps will be drawn up first,50 there wi 11 be no new maps by February 15.Would the new wetlands map be ready by June? RS The vegetation and wetlands mapping will take all spring.We hope to have the pre 1imi nary maps by June 30.Ground truthi ng wi 11 be done during the surrmer,then the final maps will be dr,awn up.FERC has stated that they will welcome any new data or maps after the June 30 submitta 1. RS -To surrmarize our agenda: 1)Get together with Jon Hall and Ted Rockwell to identify appropriate level of detail for vegetation mapping. 2)Clean up previous wor,k using aerial photography. 3)Prepare discussion of mapping,past and future,for February 15 submi tta 1. 4)Coordinate with USCE to get soi ls data. 5)Summer ground truthing. 6)Fall:final maps available. TR When do you expect to need the first USeE permit? RS -For buil~ing the access road. MG -Access road construction is scheduled to begin spring 1985. TR -After the final maps are available in late fall 1983,there will still be time for further fie]d work in the summer of 1984.If construction begins before 1985,then all permit fieldwork has to be done next summer. RS -There may be wetlands perm'its requir-ed for test drilling and other pre-construction field activities that are planned for next summer. TR -If so,they should be identified this winter to avoid any permitting delays. BB -There will be a major staging area around Cantwell,widening the Denali Highway~.and a transmission line from Cantwell to Waianae These activities may also need permits.Will the Section 404 permits require socioeconomic input? TR -Section 404 is not strictly biological,but must also consider the ,public interest which includes socioeconomics,etc. RS -How should wetlands be included in various sections of the FERC application? - - WETLANDS MEETING - 6 MG -The wh.ole wetlands section could be repeated verbatim in both the Botanical and land Use sections. RS -I would suggest that permit related discussions go into the Land Use dtapter of Exhibit E,and biological discussions into the Botanical Resources section of Chapter 3. RS -I would like to set up a project/agency group thatwi1l work together on a regu lar basis.(General agreement). BB -Someone should look into the Section 10 question. TR -I III do that and use RS and Rf as contacts. AR -Any plans for future work on wetlands should be clearly laid out in the appl icat ion. AGENDA WATER USE AND QUALITY AND F [SHfRY RESOUI{CES Monday.November 29 1:00 P.M. Introduction Project Operational Description Watana Dam Dev il Canyon Dam Access Transmission Schedule for Preparation of Exhibit E Review Process and Group Definition Tuesday.November 30 9:00 A.M. 9:00 -10:45 A.M.Baseline.Reservoir Filling and Post Project Flows and Water Levels 10:45 -11:00 A.M.Break 11:00 -12:00 A.M.Reservoir and Downstream Sedimentation and River Morphology Changes 12:00 -1:00 P.M.Lunch 1:00 -2:30 P.M.Reservoir and Downstream Water Temperatures 2:30 -2:45 P.M.Break 2:45 -4:30 P.M.Ice Processes -Existing,Construction.Reservoir Filling and Operation Wednesday.December 1 9:00 A.M. 9:00 -10:45 A.M.Groundwater Upwelling and Water Temperatures in Sloughs 10:45 -11:00 A.M.Break 11:00 -12:00 A.M.Other Water Use and Quality Concerns 12:00 -1:00 P.M.Lunch 1:00 -2:30P.M.Fishery Phenology of Susitna River System Impoundment.Devil Canyon to Talkeetna.Talkeetna to Cook In let. 2:30 -2:45 P.M.Break 2:45 -4:30 P.M.Presentation of 1982 Fishery Data 9:00 -10:45 A~M.F i <;II e ('y llilp de t S d II(j Mit i q J til)n s -Cow;t ('uc t ion 10:45 -11:00 I\.M.Break 11:00 -12:00 A.M.Fishery Impacts and Mitigations -Reservoir Fill i n9 12:00 -1:00 P.M.lunch -1:00 -2:30 P.M. 2:30 -2:45 P.M. Fishery Impacts and Mitigations -Filling and Operation Break - - ..- 2:45 -4:30 P.M.Fishery Impacts and Mitigation -Operation Friday,December 3 9:00 A.M. Summary Session -Reports by Each Group leader -Minutes of Meeting - Subject:Susitna Hydroelectric Project Water Use and Quality and Fishery Resources Workshop (see attached agenda) Location:Holiday Inn (Anchorage Room) Anchorage,Alaska Attendees:see attached Date:Tuesday,November 30,1982 9:00 A.M. Minutes recorded by:Michael P.Storonsky 1.Base 1i ne ~Fi 11 i n9 and Operati ona 1 Flows and Water Level s -Wayne Dyok (Acres) A)Summary Mr.Wayne Dyok provided an overview of the existing,and the proposed filling and operational flows and water level conditions aided by the use of overhead view graphs. B)Baseline Flow Conditions (i)Flows location of gaging stations identified the process by which the 32 year flow scenario was developed from the available data -various Susitna River basin flow contributions to Cook Inlet -monthly flow duration curves •winter low flow provided by ground water May -breakup occurs with substantial variation in flows •August flows>10,000 cfs approximately 97 -98%of the time -1~3~7~and 14 day low flow frequency curves at Gold Creek for Ju ly and August -1,3~7,and 14 day high flow frequency curves at Gold Creek for July and August r-- (i i) Annual flood frequency curve at Gold Creek ·mean annual flood 49,000 cfs Water Leve 1s -cross-section near Sherman at River Mile (RM)131 ·water level elevation with various discharges 6,000 cfs MSL 604 1 52,000 cfs MSL 611" C)Construction -Watana D)Filling -Watana ..... I I r (i) ( i i) Flows -no interruption of flow -a sill will be maintained during construction of the tunnels, then removed when the lower tunnel is complete -lower tunnel diameter 38 1 ,between MSL elevations 1420·and 1458 1 thalweg of river MSL 1450· -upper tunnel for higher flows only Water Leve 1s -winter ·pool maintained at elevation 1470' •backwater effect approximately 1/2 mile -surrmer ·mean annual flood increase elevation from 1468 1 to 1520 1 at dam ·backwater effect 2 miles -minimum flow requirements at Gold Creek •November -April 1,000 cfs -described expected downstream flows,based upon pre-project condit ions for the three hydro logi ca 1 sequences:10%,50%and 90% exceedence ·little difference during winter •October significant difference during 1992 -Gold Creek chaos en as representation of Talkeetna to Watana reach -water levels at River Mile 131 .during August~with 22~OOO cfs pre-project average vs.12~OOO cfs filling average~there will be a 1 1/2 foot change .approximately 3 foot change during early summer however~maintain at least 2 feet of water in river channel at all su mmer flows -compared Gold Creek~Sunshine and Susitna Station and indicated that differences in both flows and water levels will be moderated as you progress downstream E)Operation -Watana -minimum downstream flows 5~OOO cfs during winter -post-project flows at Watana~Gold Creek and Sunshine -Flow variability -Natural and Filling Conditions -Discharge at Gold Creek -Summarized operational change expected •substantially increase winter flows •substantially reduce summer flows Question Is there any upper limit to winter discharge and if so is it based upon fisheries requirements or power demand? Answer -Maximum Watana powerhouse flows will be 19~000 cfs. -no upper limit has been established yet -it may be desirable in future to establish maximum winter flow criteria -Gold Creek post-project winter flows will average 10~000 -can probably establish a maximum winter flow of 14,000 cfs at Go 1d Creek -Sunshine post project flow •still substantial winter increase from baseline •May and summer much closer to baseline -Susitna Station post-project winter substantial increase summer -very little difference - .... Question Answer Question Answer Answer What is the difference between winter pre-project vs. operational flows at Susitna? 14,000 cfs operational flow vs.7,000 cfs pre-project, therefore,winter flows will be doubled at Susitna Station How will Watana operate if Devil Canyon is never built? ~ave impacts been assessed for Watana alone or with both dams operational? Watana will be base-load.Most of impact assessment has been concentrated with both dams on line • Consideration of peaking should not be ruled out.It is possible to peak if only Watana is built.May have sufficient attenuation of peaks downstream in a short distance if peaks are of short enough duration,with only minor impacts further downstream as a result of attenuation. - - F)Filling -Devil Canyon 2 stage scenario -1st stage ·76,000 ac-ft. ·fill within a couple of weeks •maximum elevation 1,135 1 -one year at constant elevation 1,135 to plug diversion tunnel and comp lete dam -2nd stage ·fi 11 as quick ly as possib le ·fi 11ing wi 11 take approximately 5-8 weeks depending on energy demand 25 foot drop in Watana water level G)Operation -Watana and Devil Canyon -Watana peak -Devil Canyon baseloaded -Devil Canyon outflow similar to with Watana alone -Devil Canyon will experience approximately a 1 foot daily drawdown with Watana peaking H)Watana Drawdown and Flow Scenario Derivation (i)Minimum flow requirements - 7 scenarios studied -no difference between winter flows;all 5,000 cfs different summer flows -August was determined the critical time frame because of the need for salmon to gain access to the sloughs (ii )Net benefit from project ($)vs.August flows -10 ,000 cfs $1,220 x 10 6 -12,000 cfs $1,140 x 10 6 -14,000 cfs $1,050 x 10 6 -selected 12,000 cfs •compromises economics somewhat •provides a starting point upon which mitigation can be based Question Answer Question Are the economics of the project based upon the 1981 Batelle forecast? Yes How would the benefits vs.flow scenario change if the Batelle load forecast is incorrect and the load is reduced? Answer Not able to answer without further investigation.(Ed.note -shape of curve would basically remain the same. absolute value of benefits would decrease with lower demand forecast) II.Baseline Slough Information -Woody Trihey (Acres Consultant) A)Surmnary Mr.Woody Trihey provided a description of a side slough in the Susitna River including morphological characteristics (cross sectional profile, gradients),flows,and water profiles with various flows. ,~ B)Introduction -River System and Typical Slough -river broken into 3 segments -only discuss the Watana to Talkeetna segment -will look at flow regime only,however,quality and availability of habitat may also be affected several different types of habitat in the river system ·mainstem tr i bu tary ·side channel ·side slough -will talk about side slough habitat only,potential for most impact -currently evaluating August as most important time of the year -typical slough and river sketch ·interim channels have eroded from river to side sloughs ·very often no water through the interim channels -flows •sloughs typically clear water,low flows ·river turbid •backwater effect at mouth of sloughs - hi-gh flows heads ~f sloughs can be overtopped at high flows causing turbid flows ·flows up to 1,000's of cfs during flood conditions •flush out the fines ·act as a side channel during flood ----.----------------_,-..""'"f-'..-....---~-~----.,..------- C)Slough 9 (i)Longitudinal -noticeable ·upper •lower •river profile gradient difference between upper and lower ends 18 ft/mi le 5 ft/mile 11 ft/mi le (ii)Flows and Stage -irregular nature of the sloughs causes pools to occur at low water / ·discharge of 3 cfs.creates three pools of approximately 0.7 feet,1.5 feet and 3.0 feet. -staff gage at mouth of slough ·11,000 cfs 590 1 MSL •33,000 cfs 594 'MSL slough profiles provided at various mainstem flows •12,500 cfs 16,000 cfs ·18,000 cfs •22,000 cfs ·between 18,000 -22,500 cfs remove barrier to upstream areas of the slough •16,000 cfs creates 0.25'depth for 140'length of slough •20,000 cfs creates 0.5 1 depth for 30 1 length Question Answer Where are the spawning areas in Slough 9? Some chum salmon were observed during 1982 above the first barrier,however many were observed attempting to spawn at the mouth of the slough.However,August 1982 had unusually low flows of 11,000 -12,000 cfs and salmon had difficulty attaining access to slDughs.Normally,flows are in the 18,000 -25,000 cfs and access is not usually a problem ---------------~-~---~=====~~~--------- Question Answer Question Answer !"""Questioni F"'" Answer Question - Answer r It looks like 14,000 -17,000 cfs is needed to obtain access to slough? Yes,if only looking at flow,however utilizing engineering techniques,backwater effects could improve access. How did we arrive at 12,000 cfs?Don't we need flushing flows to clean out sloughs? We believe that this is a starting'point and that we are progressing towards a set of unique flows for each month, not there yet. Isn't the backwater effect going to change with reduced flows? Yes What percentages of sloughs with 12,000 cfs flows will salmon have difficulty with access? Can't answer right now,but should have a better handle next summer. III.Reservoir and Downstream Sedimentation -Mr.Brent Drage (Peratrovich, Nottingham and Drage) A)Summary Mr.Brent Drage provided a description of the anticipated sedimentation process in the reservoirs,among the major topics included were the mechanisms influencing sedimentation,the existing situation,and the expected changes in particle size distribution,suspended sediment concentrations and turbidity. B)Sedimentation Process Factors -if 100%trap efficiency assumed,over 100 years,only 5%of the reservoir volume lost,or 12%of active storage -factors influencing sedimentation •operational schemes mean monthly volume live storage volume ·dead storage volume ·change in surface elevation from the previous month -driving mechanisms •inflow outflow •flow thru velocity •detention time ·ice cover presernt •mean ambient temperature •mean reservoir temperature ·thermal trend •inflow temperature •flow pattern •mixing potential •thermal current velocity •wind driven current velocity C)Existing Conditions at Gold Creek (i)Suspended sediment concentrations at Gold Creek -May -Sept. -mi nimum range 10 200 mg/l -average range 200 -1,000 mg/l -maximum range 2,000 3,000 mg/l (ii)Average monthly particle size distribution -May,June,July and August fine silt and clay particles less than 12 microns most important ""'" D)Expected Conditions (i)Particle size range passing thrQugb - 3 - 4 micron range particles will pass through durin~quiescent conditions -mixing action of wind and wav€s will al'low up to the 12 micron size range to pass through the Watana Reservoi r (ii)Settling rates -Stolkes Law -as su me qu i escent cond it ions at 40 0 F 5 micron glacial particle~3.7 x 10 -5 ft/sec. 5 micron spherical particle~4.3 x 10 -5 ft/sec. (iii)Depth of particle seUl-ing over time -quiescent conditions - 2 micron particle -400 days to settle 200 ft - 5 micron particle -60 days to settle 200 ft -10 micron particle -20 days to settle 200 ft (iv)Settling column study -sample taken at Watana at flows of 17 ~200 cfs -10 foot column -350 mg/l at time 0 -10 -20 mgtl after 72 hours (v)Effects of wind and waves -wind waves will significantly effect settling within 25 1 of surf ace 10 -12 micron particles wi 11 be re-entrained within the top 25 feet -wind waves will effect at 50 1 depth signigicantly less (vi)?reaiction of particle size distributions -using Camp1s (1943) solution -gives us an idea of the size of the particles that will settle and amount of s,ediment for different settling conditions -results for maximum mixing~minimum mixing and quiescent cond itions (vii)Results of deposit model runs -maximum and average mixing (viii)Turbidity vs.suspended sediment concentrations -appears to be direct correlation maximum mixing 100 -200 mg/l =20 -40 NTU normal mixing 80 -120 mg/l =15 -25 NTU minimum mixing 10 -30 mg/l =2 - 5 NTU (ix)Literature search -extensive search conducted,but not much information available -however Eklutna Lake appeared to have the most similar characteristics Question What will the difference be between pre-project vs. post-project turbidities during winter? Answer Probably safe to say it will be between 20 -40 NTU post-project discharge. Question Has input from other sources been included? Answer They were considered,but not included in the model.It is expected that the material contributed from other sources will be coarser and settle out shortly,contributions should not be significant. IV.Eklutna Lake Study -Steve Bredthauer (R&M Consultants) A)Summary Mr.Steve Bredthauer provided the following discussion regarding the Eklutna Lake turbidity studies that were conducted due to the lake's close similarities to the Watana Reservoir. ..... B)Information Collected -Kamloops Lake,British Columbia,information available -sampling scheme at Eklutna -results •April under ice 7-10 NTU ·May isothermal 7-10 NTU mid June starting to increase,14 -15 NTU at the lower end of reservoir •mid July thermocline developing,plume ~as evident in the 10 -30 meter range at head of lake,down the lake-turbidity diminished •September -unusual turbidity at reservoir bottom -flows probably entering as underflow -summary -Eklutna Lake data indicates the sedimentation process at Watana will be heavily dictated by densities of the river and reservoir waters v.River Morphology -Steve Bredthauer (R&M Consultants) A)Summary Mr.Steve Bredthauer utilized overhead view graphs to facilitate his River Morphology presentation which highlighted the basic morphological systems of the river,a breakdown of the river by morphological reaches concentrating on the river downstream of Devil Canyon and the expected morphological changes • B)Morphology of the River - (i)Four basic systems -main channel -side or split channel -(Sloughs) -braided channel -floodplain 1 - 2 miles wide,large bedload movement -Delta Islands 50 -60 mi les upstream of the mouth (ii)Morphological reaches of the river -upstream of Devil Canyon .first 20 miles braided headwaters .next 55 miles split channel west from Tyone River to Dev il Canyon dams He-steep canyons -Below Devil Canyon RM 144 -149 -single channel RM 139 -144 -valley broadens~with split channel RM 129.5 -139 well defined split channels~sloughs RM 119 -129.5 -split channel configurations~stable shoreline RM 104 -119 -well defined single channel RM 95 -104 -Susitna-Chulitna confluence -braided system~ aerial photo comparison shows this section to be a very dynami c area of the ri ver RM 61 -95 -braided~debris damming,very dynamic RM 42 -61 -Delta Islands -rapid erosion evident RM 0 42 Yentna River confluence,major tributary,40% of river flow (ifi)Expected Changes -bedload movement curves .10 -30 mm size range moved with 10~000 -20,000 cfs flow immediately downstream .armouring will allow a well defined stable channel to occur tributaries analyzed 17 streams for degradation .six were found to have potential problems with either perching or degradation in summary the river will be better defined,more stable and more deeply extrenched B)Results -Eklutna A)Summary VI.Eklutna Lake Water Temperature Study -Steve Bredthauer (R&M Consultants) isothermal 4 -5°C a little surface warming to 8°C gradual warming sharp thermocline in some areas~gradual temperature variation in others~12°C -5°C same as above sharp thermocline maximum 13°C 15°C maximum~lessening thermocline cooling isothermal 7 -9°C isothermal 6 -8°C i sot herma 15°C average weekly temperatures at Watana gaging site ·October -April ooe •May starts to climb •maximum of 12 -14°C during summer -1981 temperature variations at Vee Canyon~Denali and Susitna Station •warming with distance downstream 1981 Denali and Watana water temperature comparison -1982 Susitna River vs.Indian River and Portage Creek temperatures lower temperatures in tributaries than mainsteam •temperature varies between tributaries Susitna River Data May 25 June 18 Ju ly 2 Ju ly 14 Ju ly 28 August 10 August 24 Sept.9 Sept.21 Oct.14 Nov.4 Following lunch~Mr.Steve Bredthauer provided a discussion of the results of the 1982 Eklutna Lake water temperature montoring program and the Susitna River temperature data that is being and will be used to calibrate the DYRESM temperature model for Watana. C) - - - - VII.Reservoir Temperatures -Mr.Wayne Dyok (Acres American) A)Editor's Summary Mr.Wayne Dyok provided a generic description of expected reservoir and outflow temperatures during the filling and operation processes and the DYRESM model used to estimate the temperatures. B)Filling -Watana -1st year fill frOm 1470 1 -1800 ft •outflow temperatures will be a composite of inflow temperatures •low level outlet will not allow the normal temperature variation -from autumn of the 1st year until powerhouse is available for use, 4°C temperature water will be discharged ·no mechanism for mitigation at this time C)DYRESM Model -investigated all available temperature models and found DYRESM to be as good as any used successfully in Australia and British Columbia Question Answer How close will DYRESM model the Watana temperatures? Currently working on it.We feel confortable with the summer modeling that has taken place.Ice cover subroutine has some bugs but we are working with the author to correct them. D)Temperatures (i)Reservoir temperature profile June 1 -September 30 -Eklutna Lake inflow water temperature 3°C •glaciers very close to head of lake -Watana inflow temperatures as high as 10°C different thermal structures between the two reservoirs --multi-level intake structures • 4 intakes within upper 120'of the reservoir (ii)Watana outflow temperatures -July -mid September,we feel confortable that we can maintain very close to natural temperatures -mid-September -early winter,we will only be able to provide 4°C water •O°C water that naturally occurs will not be possible •over the course of the winter,temperatures will drop to about 2°C -, Question Answer Question Where will the thermocline be during winter? Probably very close to surface as was observed at Eklutna. Within the first two meters the temperature was 3.6°e and virtually isothermal below. Are these downstream temperatures at the immediate outlet of the project? Answer Yes. Discussed water temperatures at Williston Reservoir on the Peace River where a gradual winter profile varying form ooe at the surface to 3°e at 300 feet existed. Question Answer Question Answer Best guess when ice cover on reservoir will form? Depends on wind conditions,ambient air temperatures,and when an isothermal situation occurs. Has the model been run for winter yet? No,but we are estimating that outflow temperatures will probably be between 2 -4°C. Question Answer Investigations into the expected winds on the reservoir? Will wind increase? Yes,Lake Ontario has 20%higher winds than adjacent lands. A lake this small may have about a 3-4%increase in winds over what currently exists. (iii)Devil Canyon Temperatures -temperatures will largely reflect Watana temperatures -DYRESM model not run yet for Devil Canyon. VIII.Downstream Temperatures -Mr.Tom Lavender (Acres) A)Summary Mr.Tom Lavender provided a description of the Heatsim heat budget model that is being used to describe expected downstream temperatures during the various phases of the project. B)Heatsim -Heat Budget Model for River Reaches -streamwise,daily heat balance,reach by reach from prescribed upstream boundary thermograph and inflow hydrograph -uses:air temperature;vapor pressure;wind speed;solar radiation; cloud cover;albedo;i.e.,a complete heat balance -accounts for:heat content of rainfall and snowfall,insulating effect of ice cover on small (well mixed)reservoirs;hydraulic mean depth and velocity of stream in each reach yields:components of heat balance;net daily heat gain or loss to river reach;inflow and outflow temperatures for reach;length of ice-free reach (optional) -based on (in large measure):J.M.Raphael,ASCE Journal of the Power Division,V88,No.P02,p.157,July 1962. C) - Temperatures -pre-project -Watana alone -Watana/Devil Canyon - - """ - - Question Answer Question Answer Question Answer Question Answer Question Answer Question Answer Did you use the ice formation option of model to determine ice cover formation location? We will cover that in my next discussion Analyzed temperature variations with mainstem discharge yet? We have not done a sensitivity analysis yet.During summer probably not significant variation during winter could be more significant. If Watana peaks will it affect temperatures? No not on a daily average basis. What flows is the model based upon? Normal operational flows expected,not minimum flow requ i rements. Need for sensitivity analysis with various climatic and flow conditions? Yes Why multiple intakes at Devil Canyon if temperatures will not be altered from Watana? Two month residence time will create slight variations,try to match outflow temperatures as close as possible to natural. Question Will there be additional graphics in the report that further describe the expected minimum winter temperatures of 2°C+ when both projects are operating? Answer Yes IX.Ice Processes,Causes and Effects -Tom Lavender (Acres) A)Summary Mr.Tom Lavender presented a description of the major factors influencing the ice processes,namely the hydrologic and thermal regimes and their impacts upon the ice front location,water levels and the ice cover. B)Hydrologic and Thermal Regimes -described existing variations throughout annual cycle principal factor controlling the ice process is flows -described proposed hydraulic and thermal regimes •flows will be smoothed out throughout the year .thermal energy will be transferred from summer to winter C)Ice Front Formation (i)Natural lodgement points are a constriction in the river where the ice cover formation process begins -construction of the Watana dam will not affect the ice cover formation process since a natural lodgement point exists (ii)Temperature immediately downstream -water temperature .when bulk water temperature reaches O.loC,ice will begin to form at surface of river -air temperature •discussed ice front location with warm,average and cold climatic conditions and regulated discharges (iii)Expected ice front location D)Water Levels Leading Edge Stability (Froude No.) -Froude No.will be between 0.08 and 0.154 -gives the range of the change in the water surface elevation given the discharge rate •3'-4'increased river stage between Sherman'and Talkeetna -areas with an ice cover will experience increased stage levels -areas without the ice cover may experience slightly lower stage levels than normal winter conditions E)Ice Cover Thickness -effects of discharge .thickness dictated to a large measure by discharge at the time of freeze-up F)Effects of Varying Discharges on Ice -same processes govern spring break-up as govern freeze-up -hinging of ice occurs with raised water level Question Answer Question Answer Will there be an increased ice thickness at Susitna Station due to doubled winter flows? Yes Will there be problems with ice breakup due to this increased ice thickness? No,due to the thermal degredat i on of ice in the upper Susitna and the regulated flows. Question Answer Question Answer Question Answer Question Answer Question Answer Question Answer Will increased flows and staging cause flooding of sloughs during winter with accompanying increased ice thickness? It will depend upon the elevation of the upstream berm. Will the magnitude of breakup in the downstream reaches be more severe or less severe? Magnitude unknown.(Ed.note ~breakup should be less severe) Do you know if ice will form and where between Devil Canyon and Talkeetna? It will depend upon climatic conditions. What will the stage increases be? 3'-4'increase between Sherman and Talketna. Definitely have overtoppng of sloughs with these increases. Will erosion problems occur with these increased flows? None that don't already occur under natural flow conditions with ice jams.With ice jams.velocities can reach 9 -10 ft/sec.Normally 3 ft/sec velocity under ice is required before the ice front can progress upstream. Will any analysis be done of impacts to sloughs from ice processes? Talk to AEIDC.who will be handling the impact assessment. No comment from AEIDC. Question Answer How will sloughs be affected morphologically from ice processes? Have to do a detailed analysis of existing conditions first. LIST OF ADDENDEES WATER USE AND QUALITY &FISHERY RESOURCES Holiday Inn,Anchorage,AK Tuesday,November 30,1982 Name Organization Telephone Wayne Dyok Acres 276-4888 Woody Trihey Acres Consultant 274-7583 Steve Bredthauer R&M Consultants 279-0483 Tony Burgess Acres 716-853-7525 Bill Lawrence U.S.EPA 271-5083 Brad Smith NMFS 271-5006 Len Corin USFWS 271-4575 Mary Lu Harle ADNR-Water Management 276-2653 Gary J.Prokosch ADNR-Water Management II Ken Florey Fish &Game 344-0541 Eric Myers NAEC 276-4244 Tom Lavender Acres 276-4888 Tom Arminski Alaska Power Authority 276-0001 Steve Zrake ADEC 274-2533 Gary Lawley Harza/Ebasco 277-1561 John R.Bizer Harza/Ebasco .1\ Jack Robinson Harza/Ebasco \I Leslie Griffiths Peratrovich,Nottingham,Drage 277-8633 Brent Drage Peratrovich,Nottingham,Drage II Phil Brna ADF&G 344-0541 Bill Wilson AEIDC 279-4523 Ken Voos AEIDC II Larry Moulton Woodward-Clyde 276-2335 Jean Baldridge Woodward-Clyde II Michael P.Storonsky Acres 276-4888 Kevin Delaney ADF&G 344-0541 David Wangaard USFWS 263-3316 -Minutes of Meeting - Subject:Susitna Hydroelectric Project Water Use and Quality and Fishery Resources Workshop Location:Holiday Inn (Anchorage Room) Anchorage,Alaska Attendees:see attached Date:Wednesday,December 1,1982 9:00 A.M. Minutes recorded by:Michael P.Storonsky 1.Slough Access Mitigation Ideas -Woody Trihey A)Summary Mr.Woody Trihey presented some possible mitigation techniques that should be considered for muintenance of adequate slough water levels, namely increased mainstem discharges,amplication of backwater effects at the mouth of slough,increased flow through the sloughs,or modification of slough channel and entrance. B)Introduction profile of slough discussed yesterday with flow effects on various barriers to upstream movement -pre-project August flows .18,000 +cfs very common occurence .10 -12,000 cfs very rare occurence,however these flows are natural occurences in early September flows of 12,000 will provide problems for fish to gain access C)Mitigation Ideas (i)Increase mainstem discharge -variability of tributary inflow •Project should not have significant effect on weather patterns in river valley therefore,natural tributary variability would occur and create downstream flows of 20 -25,000 cfs. ·Try to quantify the occurrence and magnitude of these use of controlled releases variable spikes •duration and magnitude of variable spikes sufficient to avoid attenuation and provide access (ii)Amplify mainstem backwater effect -submerge a sill downstream of mouth of slough -construct dike to protude into mainstem and cause back water effect in slough (iii)Increase flow in slough -collect and concentrate local surface runoff and channelize -divert water from mainstem -withdraw water from a local storage pond •stored via natural runoff ·pumped from river •pond could contribute to local groundwater upwelling -increase groundwater inflow (iv)Modify slough channel and entrance -deeper entrance of some sloughs have to be careful if deepening slough,spawning habitat could be degraded since most spawning is in riffle areas,need to maintain riffle/pool ratios -constrict channel width,therefore deeper water levels -submerged weirs,create pool and drop scenario (v)Summary -Mr.Trihey does not recommend any of above at this time"but providing them as possibilities for everybody to think about. - Question Answer Question Answer Answer How many sloughs are we talking about?number being used? how many can we modify? Get a better answer if you ask later,Tom Trent's unit more f ami 1i ar •12 -15 sloughs quite heavily used -similar to slough 9 •trying to maintain the chum and sockeye fishery above Talkeetna •approximately 38 sloughs between Talkeetna and Devil Canyon Are there problems with ice,with the use of weirs and submerged sills? Not advocating any of these alternatives,there could be problems with ice.We have to look at all the various sloughs more closely and evaluate the alternative mitigation more thoroughly before deciding.Just trying to emphasize that there are many ways to attain access to sloughs besides increasing flow.A lot of work still needed. Emphasized that he was only talking about access to the sloughs and not the quality of habitat that will be avai 1ab leo May get variations in slough morphology due to ice processes and flow.Look at the gradation of material and the ra"infall events that might alter slough morphology. Not a lot of change in sloughs expected,cobble size substrate at most slough mouths,little change anticipated.However, significant changes in tributary mouth morphology expected. Ice processes are probably the primary force causing slough formation. Ice probably a major factor but flows can also work to form sloughs. High flows move sand and silts,but there is larger substrate at the slough mouths and probably will not be greatly altered. Larry Moulton's group will be discussing these thoughts in further detail. II.Groundwater Upwelling and Water Temperature in Sloughs -Tony Burgess (Acres) A)Surrmary Mr.Tony Burgess presented a discussion on the various factors that influence slough groundwater regimes,the investigations that have occured,the modeling that has been conducted,and the conclusions that have been drawn.In addition,he discussed the factors that influence ground water temperatures and the impacts expected. B)Introduction (i)Slough morphology -bar separates slough from mainstem bar may be overtopped •as ice front passes through •during breakup jams •under open water storm discharge (ii)Stratigraphy -silt/sand up to 6 feet deep -sand/gravel/cobbles/boulders -possibly occur with depth -bedrock at unknown depth •drilling to 40 1 has not reached bedrock C)Groundwater Investigation (i)Techniques -walk overs -test pits and installation of standpipes, -soil drilling and installation of piezometers and glycol tubes -observations of surface and ground~ate~elevations,water temperatures,slough discharge,seepage flux (ii)Slough 9 -drill holes identified -continuous monitoring -Slough 9 overtops at approximately 20,000 cfs -significant ice jam last winter -bulk of river flow went through Slough 9 rather than through the mainstem (iii)Seepage flux measurements identified upwelling area -estimate flux into sloughs -haven't done many of these yet and haven1t reduced data yet (iv)Slough 8A -groundwater gradient approximately the same as river gradient (v)Slough 9 -general gradient in downstream direction D)Groundwater Modeling -geometry,boundary conditions and material properties all influence the constitutive relationships that in turn create a response -constitutive relationships •Laplace's equation •Darcy I slaw Q =KiA flow =(Hydrologic conductivity)(gradient)(cross section) Flow lines orthogonal to and from river -groundwater flows - 3 types -geometry ·shape of area be i ng mode 11 ed ·3-D,2-D (plan,cross section)1-0 (along flow line),thickness (D) -boundary conditions •values of dependent variables (head,flow)along boundaries material properties ·hydraulic conductivity (K)(permeability) ·porosity (n) •transmissivity (T =K x D) •storage coefficient (S) -hydraulic conductivity ·laboratory grain size analyses with empirical formula K =(100 to 150)x dl0 2 ·field tests in drillholes constant head falling head pumping test flow net sketching and discharge measurement response of aquifer to well defined boundary event -Grain size analysis of Slough 9 bank ·gravel and sand -Slough 9 flow net ·identified flow lines -Hydrographic Response ·sudden change in mainstem water level influences the aquifer looked at the response in the Slough 8 wells from a sudden change in water level.Reasonable response on the increasing limb of the hydrograph,however higher than expected water levels occurred on the decreasing limb of the hydrograph.We will continue to invest i gate. -Summary of ReSUlts ·grain size analysis K =6 x 10-2 cm/s •field tests not yet completed - •Flow net T =9000 ft-1 dm/x for 0 =lOa'(assumed) K =3.2 x 10-2 cmls •Hydrograph response T =1200 to 306000 ft 2jd for 0 =100 1 (assumed) K =4.27 x 10-3 to 1.09 cmls -Modelling •Groundwater flow flow net sketches and hand calculations finite element analyses using computer ·Temperature no flow thermal regime coupled groundwater-thermal regime -graphic slough model -contours -boundary heads -fl u xes -contours fixed heads in mainstem and sloughs identified high bedrock and valley side slope •remainder of slough constant saturated thickness -Conclusions General groundwater regime can be modelled using 2-D plan idealization.Locally,match not so good:may be due to variation in saturated thickness,variation in hydraulic conductivity,or boundary recharge. •Flow is generally downstream and laterally towards slough from up 1and areas. E)Thermal Processes and Modelling r .- (i)Baseline -Susitna mainstem •mid October to mid April O°C •maximum +10°C July ·Annual mean approximately 3°e Talkeetna air temperatures ·minimum mean monthly -13°C •maximum mean monthly ·annu a1 mean -groundwater •upwelling approximately +3°C •wells O.05°C (May)to 6 -8°C (September),locally as high as 11°C (ii)Preliminary conclusions -Air temperature variations do not have a significant direct impact on groundwater -Upwelling t€mperatures nearly constant but shallow well temperatures show seasonal fluctuation lagging main stem -Upwelling temperature is approximately mean annual main stem temperature (iii)Dispersion -Dispersion theory developed for contaminant transport -apply to thermal problems by making temperature equivalent to contaminant concentration -dispersion occurs in all porous media.The extent of dispersion increases as the medium becomes more heterogeneous ·diagrams of dilution variations with different materials •examp le cited (iv)Conclusions -upwelling temperatures can be explained in terms of dispersion (mixing)of mainstem seasonal variations within groundwater flow path -but why do near surface grounwater temperatures show less mixing? Possible factors: •path length shorter ·gradient steeper materials more homogeneous -recent deeper drilling,piezometer and glycol tube installations should provide important data - ..... F)Project Impacts (i)Geometry May be some changes due to deposition and scour. (ii)Material properties Generally will not change except possibly due to scour/deposition effects. (iii)Boundary Conditions River stage:higher in winter,lower in spring/summer with less variabi 1ity -Temperature:mean annual little change,slightly higher in fall and lower in summer. (iv)Response to Stage Change Based on data from September hydrograph,response is quite rapid, in near surface wells.Deeper wells may respond slower due to longer flow path. (v)Effect of Stage Change on Extent of Upwelling Could be modelled but unlikely that sufficient data (spatial variation of K)available.Field monitoring and observation preferred . (vi)Mitigation Not looked at yet Question Answer Will river stage be higher during winter or lower? There could be lower water levels without an ice cover depending on the particular circumstances.Ice cover will be vari ab leo Question Answer Question Answer Question Answer Question Answer Both upper and lower water levels would drop equally therefore the same gradients would still exist so groundwater flow will continue but at lower elevations. Does the storage of water in the gravel from late summer flow provide winter groundwater flows? Some water is stored.but not alot.There were rapid responses observed in the wells due to mainstem discharges. During October upwelling continued with a decreased discharge. If there is not much storage from late summer flow.this would indicate upwelling continues at low discharge. A fair amount of upwelling occurred throughout February and March. Freezing near the banks cold be concentrating upwelling towards the middle of the slough. If you drop the invert elevation 3 - 4 feet would it intercept more grounwater? No.that only amounts to a small portion of the 2000 feet of head upstream of the slough. Is there a monitoring program envisioned for grounwater upwelling? Recommended continuous temperature and flow monitoring in wells.Half-barrel technique to quantify seasonal variation. So far only 1 field trip to a half-a-dozen locations. Isn't there variability between the sloughs?Why only slough 9 investigated? Trying to understand the processes.first.Now we can look at other sloughs and determine the variability. Question Answer Question Answer With post-project winter flows of 10,000 cfs,will the location of ice formation dictate upwelling? Probably not change upwelling,upstream and downstream elevations experience equal change,therefore the gradient is the same. Will absence of flushing flows cause disturbances to upwelling locat ions? Only affect near surface sediment,may move upwelling area slightly. May shift location of upstream most upwelling areas. - III.Other Water Quality Concerns -Mr.Steve Bredthauer (R&M Consultants) A)Summary Following an intermission,Mr.Steve Bredthauer discussed the balance of the major water quality concerns including nitrogen supersaturation, eutrophication,leaching,and dissolved oxygen. B)Nitrogen Supersaturation -caused by high plunging spills -measurements above and below Devil Canyon indicate s~persaturation currently exists -project will employ fixed-cone valves to avoid plunging spills that might create a problem C)Eutrophication -limited data available for the four nutrients,N,P,C~Si -phosphorous is the limiting nutrient -two methods available •Dillon and Rigler model -rejected due to the limited ability to estimate phosphorous retention coefficient •Vollenweider model chosen -used at Crescent Lake,Alaska with good resu 1ts -Vollenweider model used by Larry Pederson of Fairbanks •predicted oligotrophic situation •need approximately 115,000 residents dumping untreated waste into Watana reservoir to produce eutrophic situation D)Leach i ng -increased concentrations of metals and other parameters immediately after closure of dam -decreased leaching with time -Watana ·buried with inorganic glacial sediment •most readily dissolvable materials will dissolve first -effects of leaching at Devil Canyon will remain longer ·little sedimentation expected effects expected to be confined to reservoir bottom -no significant impacts anticipated E)Dissolved Oxygen -decreased potential for oxygen saturation with increased depth -COD coming into reservoir is low -no vegetative growth expected along shoreline during drawdown -no dissolved oxygen problems expected in the upper levels of reservoirs or downstream Question Answer If you expect the reservoir to act as a nutrient trap,how will this effect the productivity downstream? You do not see organisms taking aavantage of nutrients "in the mainstem since the nutrients are so low.Most organisms taking advantage of nutrients in the system are in the backwater areas and tributary mouths. Impacts from reduced nutrient concentrations should not affect the rearing that is taking place in the tributary.mouths. -Question Most primary and secondary productivity is occurring in the side sloughs,side channels and tributary mouths. Very high levels of hydrogen sulfide were observed at a hydro project in southern Alaska.Is a simil'ar problem expected? --i Answer No IV.Summary of Water Quality Discussions Mr.Wayne Dyok (Acres) A)Summary Mr.Dyok provided a sumary of the water quality discussions of the last day and one half including:flows and water levels,temperatures,ice, suspended sediment and turbidity,and sloughs. B)Flows and Water Levels 1.Construction:Impacts limited to immediate area of damsites 2.Filling:Winter flows -similar to natural regime except for reduction in October and November 1992 at Gold Creek.Summer flows -substantial reduction at Gold Creek.Downstream -reduced percentage difference (maximum reduction 18 percent Susitna Station).Stage reduction up to four feet May through July.Stage reduction of about two feet during August,Talkeetna to Devil Canyon. 3.Operation:Winter flows increased to about 10,000 cfs at Gold Creek with extremes at 6,000 cfs and 13,400 cfs.Susitna Station flows increased by a factor of two.Summer Gold Creek flows reduced to 12,000 cfs during August.Susitna Station monthly flows reduced by maximum of 13 percent.Water levels -Watana reservoir maximum drawdown 120 feet.Devil Canyon drawdown up to 50 feet August and September.Summer water levels Talkeetna to Devil Canyon reduced by about two feet in August.Minimal water level changes downstream of Talkeetna during summer. Question Answer Where is the information on expected water level changes in the Report on Water Use and Quality? Not included,water levels changes will be addressed in final document. B)Temperature 1.Construction:No impact. 2.Filling:4°C water at outlet during second year of filling.Gold Creek temperatures could be as low as 6°C. 3.Operation:By selective withdrawal Watana outlet temperatures can be made to approximate natural regime during summer.Fall temperatures will be warmer than natural at outlet and for some distance downstream.Winter outlet temperatures will ikely be between 2°C to 4°C. C)Ice 1.Construction:No impact due to natural lodgement point near Watana damsite. 2.Filling:Minimal impact bec~use natural flows are approximated during freeze up and natural temperatures are attained at Devil Canyon.Reduced ice jamming during spring breakup because of decreased flows from Devil Canyon to Watana and thermal decay. 3.Operation:Approximately three to four foot increase in stage during freeze up with effects to Cook Inlet.Reduced ice jamming during breakup Devil Canyon to Cook Inlet.Watana alone -ice front will be between Sherman and Portage Creek.Watana/Devil Canyon - ice front will be between Talkeetna and Sherman. -. ,""'" - Question Answer Question Answer It was indicated that there will be a reduced ice breakup downstream nearer to Cook Inlet.Is this correct,since there will be an increase in ice thickness due to higher flows? Although there will be more ice,spring flows will be reduced and therefore ice jams should be fewer and less severe. I ce wi 11 be gone above Ta"1 keetna before the rest of the ri ver breaks up,therefore no ice going downstream from the upper Susitna. What effect will the change in flows and water levels have on the estu ary? Resource Management Associates modeled the change in salinity. The model indicated a 1 1/2 part per thousand (ppt)maximum change from natural conditions.The salinity range under project conditions is expectd to be less than which presently occurs.This change is not expected to be significant. D)Suspended Sediment Particle sizes of three to four microns will pass through reservoir. Approximately 80 percent of suspended sediment will be removed. Turbidity at Watana outlet will be between 10 to 50 NTU.Lower sUl11ller turbidity.Higher winter turbidity.Downstream channel will remain stable because of armoring. E)Sloughs -Backwater effects -Surface water runoff? -Groundwater upwelling -dominant flow in direction of mainstem flow - upwelling flow rates basically unchanged although there is a potential for dewatering spawning areas in upper locations of some sloughs that are adjacent to ice free reaches of the mainstem Susitna. -Groundwater upwelling temperature -function of long term average annual mainstem Susitna River temperature. Overtopping under post-project conditions where ice in mainstem is adjacent to sloughs. -Morphological changes? Question Answer Have navigation and recreation impacts been addressed? Yes,River divided into sections above and below Talkeetna. Numerous cross-sections studied,no problems were immediately identified above Talkeetna.However,one site located between sloughs 8 an9 9 was difficult to navigate this past summer with natural flow conditions.The area was navigable.During post-project conditions caution will be needed in this one section.The normal variations in river morphology that currently occur below Talkeetna -probably will not be as significant.Kayaking will be eliminated in the Devil Canyon reach.Recreational boating on the reservoirs will be available if the reservoirs are open to public. Additional information available in the Recreation Report. Question Answer Question Answer Question Answer Question Answer Question Answer Question Answer Increased stage impacts to sloughs from ice?Impacts to sloughs from the thermal degredation of ice rather than the flushing out of this ice that normally occurs?Impacts to sloughs from lack of flushing flows to rid them of rotting salmon carcasses and the putrification that will result? If a major ice jam occurs,river flows could be directed through sloughs. What if no ice jams occur and the ice is not flushed out? The ice cover will melt in place if there is no diversion from the mainstem.It will disappear at a later date.Look at the current system for ice blocks that thermally degrade to get an idea of what will occur.Some ice blocks have been evident until the end of June. Can temperature model estimate these ice conditions? Probably can with a combination of river temperatures and groundwater temperatures. Is there a problem for the salmon if the ice remains in the sloughs? Could be depending on the habitat and its type of use by species involved. How can we mitigate the putrification problem in sloughs? Possibly flush system during wet years. How often do we need to flush? Don't know,a lot of variaiblity in the different sloughs. V.Possible Flow Variations -Dr.John Hayden (Acres) A)Summary Dr.Hayden provided a brief impromptu discussion about possible variations in river flows that might be available to benefit salmon. B)Selective Flow Spikes -spring,6 days at 20,000 cfs to facilitate outmigration and flush system -summer,12 days at 20,000 cfs to facilitate entrance to sloughs -we have to learn more about the fishery system to determine the most desirable time frames for these spikes Statement We also have to keep in mind the other uses of the river, i.e.,recreation,when considering spikes. Question The impacts of increased temperatures on over-wintering fish is not discussed in report.Increased temperatures will cause increased metabolic rates in the over-wintering salmon without an available food supply.As a result these fish could go into the next spring in a weakened condition. Answer This will be addressed in the Fisheries Presentation. We don't have enough information on the over-wintering locations to assess impacts and provide mitigation at this poi nt -j n time. .-- LIST OF ATTENDEES WATER USE AND QUALITY &FISHERIES WORKSHOP (2nd Day) Holiday Inn,Anchorage,AK ~Wednesday,December 1,1982 -9:00 a.m.Name Organization Telephone Jean Baldridge 1~00dward-C1 yde 276-2335 Michael P.Storonsky Acres 276-4888 Tom Lavender Acres " Tony Burgess Acres " Woody Trihey Acres Consultant 274-7583 Steve Bredthauer R&r~Consul tants 279-0483 Bill Lawrence U.S.EPA 271-5083 ~~Brad Smith NMPS 271-5006 Len Corin USFWS 271-4575 Mary Lu Harle ADNR-Water Management 276-2653 Gary J.Prokosch ADNR -loJater 276-2653 Chris Godfrey U.S.COE-Reg.Function 552-4942 Ken Florey Fish &Game 344-0541 Eric Myers NAEC 276-4244 John Wiles State Parks 264-2115 Dave Wangaard USFWS 263-3316 John Hayden Acres 276-4888 Wayne Dyok Acres " Bill Wilson AEIDC 279-4523 Ken Voos AEIDC 279-4523 John R.Sizer Harza/Ebasco 277-1651 Steve Zrake ADEC 274-2533 Stuart Burnell Morrison Knudsen 263-3611 F Larry ~10u1 ton Woodwa rd-C1 yde 276-2335 1 :00 p.m.Additional Attendees: F"Judy Zimicki NAEC 277 -2134 Larry Hechart AOF&G 344-0541 Kevin Del aney ADF&G " .-Mike Mills AOF&G II Dan Wi 1kerson AOEC 274-2533 Tom Trent ADF&G 274-7583 Dana Schmidt ADF&G II Bruce Barrett ADF&G II Christopher Estes ADF&G 11 Alan Bingham ADF&G II ~Richard Fleming Alaska Power Authority 276-0001 ..... MEETING SUMMARY EXHIBIT E Water Use and Quality and Fisheries Resources Section Holiday Inn,Anchorage,Alaska December 1,1982 Afternoon Session Attendees Name Judy Zimicki Woody Trihey Bill La~Hence Brad Smith Len Corin Mary Lu Harle Gary J.Prokosch Chris Godfrey Ken Florey Eric Myers John Wiles Dave Wangaard John Hayden Wayne Dyok Ken Voos e'rganization NAEC Acres EPA NMFS USFWS ADNR ADNR COE ADF&G NAEC State Parks USFWS Acres Acres AEIDC Name John R.Bizer Steve Zrake Larry Moulton Jean Baldrige Larry Hechart Kevin Delaney Mike Mills Dan Wilkerson Tom Trent Dana Schmidt Bruce Barrett Christopher Estes Alan Bingham Richard Fleming Organization Harza/Ebasco ADEC Woodward-Clyde Woodward-Clyde ADF&G ADF&G ADF&G ADF&G ADF&G ADF&G ADF&G ADF&G ADF&G APA INTRODUCTION -Larry Moulton,Woodward-Clyde Consultants (WCC) We have focused on habitat for impact assessment and mitigation planning.Although we cannot presently quantify impacts or present a detailed mitigation plan,we can discuss ~he general types and magnitudes of fisheries impacts likely to occur.Studies to quantify impacts and determine the level of mitigation necessary are either ongoing or in the planning stage. 1 -- - - We have divided the river into four general habitat types: o mains tern, o side channel, o slough,and o tributary. We considered three general reaches of the river: o Impoundments Zone, o Talkeetna to Devil Canyon,and o Cook Inlet to Talkeetna. Each reach will have different impacts associated with the various stages of the development. We did select evaluation species based on the criteria developed by u.s.Fish and Wildlife (USFWS)and Alaska Department of Fish and Game (ADF&G).Because of expected impacts,we focused on salmon spawning activities in slough habitats between Talkeetna and Devil Canyon (Table 1). 1.Chum salmon are most abundant in these habitats. 2.Sockeye salmon are not as abundant as chums but sloughs provide almost all spawning habitat for sockeye in this reach. 3.Chinook and coho salmon do not spawn in the sloughs.So here we are mainly concerned about juvenile fish which rear in slough and mainstem habitats. 4.Pink salmon spawn mainly in tributaries with only slight use of slough habitats. For the Impoundment Zone,we selected Arctic grayling as the evaluation species. 2 The different species occupy the river at slightly different times (presented phenology chart.Figure 1). Q Could some of th£differences from 1981 to 1982 could be due to differences in catchability of fish between the high and low flows experienced between 1981 and 1982. A ADF&G (Su hydro)staff will be here shortly to answer your question. CONSTRUCTION IMPACTS Impacts expected during construction are expected to be similar to those experienced by other major construction projects.In the case of the two dams.the impacts are expected to be fairly localized.A construction practices manual will be prepared to assist the contractor in avoiding and minimizing environmental damage. Major Impacts 1.Loss of habitat in mainstem due to river diversion. 2.Diversion tunnel will have high velocities and fish losses are expected to result. 3.Short-term turbidity problems. 4.Concrete batching operation will produce effluent requiring treatment. 5.Accidental spills are a consideration. 6.Material sites and borrow areas will be located within the impoundment with the exception of Borrow area E.known as the Tsusena Creek borrow area.This area will be rehabilitated to provide aquatic habitat. 3 .... - ~- FISHERIES BASELINE STUDIES Tom Trent (ADF&G Su Hydro Project Manager) ADF&G conducted reconnaissance during the winter of 80-81.We began full scale investigations in June 1981.Presently,we have completed two cycles of open-water season studies and are getting the winter 1982-83 program underway.Our program is divided into three areas: o Adult anadromous, o Resident and juvenile anadromous,and o Aquatic habitat and instream flow studies • Our task is mainly one of data ~ollection but we are doing some analysis to describe preproject relationships.Our reporting schedule includes our basic data reports which will be produced by Jan.31, 1983.These will contain very little analysis.Our interpretive reports which will contain our analyses will be produced by June 30,1983. Christopher Estes (ADF&G Su Hydro -Aquatic habitat and instream flow program) Discussed ADF&G 1981 reports and 1982 habitat report. During the 1982 field season,the aquatic habitat program collected habitat data to assess the influence of the mainstem discharge on other habitat types.We established study sites in slough habitat and collected water quality,hydraulic,and substrate data in six side sloughs upstream of Talkeetna:BA,9,11,16,19 and 21. Downstream of Talkeetna we established study sites in two areas,Chum channel,a side channel and Rabideaux slough.We will evaluate the influence of mainstem discharge on these habitats. The aquatic habitat program also provided support for the resident and juvenile anadromous studies. Dana Schmidt (ADF&G Su Hydro -Resident and juvenile anadromous fish program) In addition to the resident and juvenile anadromous program~I have also been involved in a dissolved gas study upon which I recently presented a paper at the American Fisheries Society meeting in Sitka. Devil Canyon has larye plunge pools which cause entrainment of air resulting in nitrogen supersaturation.A continuous recorder was installed near the mouth of the canyon to measure nitrogen concentrations in the canyon.Measurements were collected to determine the downstream dissolved gas profile to assess the decay rate of nitrogen in the system.Peak concentrations of 117%were recorded in the canyon. Resident and juvenile anadromous fish program. The adult anadromous program is tracking the adult salmon.We will be following through with the incubation of the embryos.In conjunction with the USFWS~we will determine development rates under various temperature regimes.In addition we will be evaluating: o Rearing habitat in sloughs and side channels~ o Timing of outmigration (smolt trap 6/18 to 10/10) o Population estimates of grayling in the impoundment zone. (These estimates will be stratified by age classes and may be available by Jan.31.) We will be determining fish distribution and relative abundance~ through electrofishing and minnow trapping.,Telemetry studies are being conducted on rainbow and burbot. We will be assessing changes in habitat in response to changes in flow. 5 ,- We have begun a study of food habits and availability of invertebrate populations. Bruce Barrett (ADF&G Su Hydro -Adult Anadromous Program) Conducted adult anadromous investigations from the confluence of Devil Creek to the estuary mainly on eu1acon,salmon,aqd Bering cisco. Eu1achon studies were conducted from May 15.to ~une 9 using gill nets and e1ectrofishing units.Spawning activity was located from RM 4.5 to RM 48 primarily below the Yentna River confluence.There appears to be two populations of eu1achon using the lower Susitna River.The size of the run is in millions of fish.The spawning run is mainly composed of 3 year old fish.The fish were spawning in riffle zones with unconsolidated sands and small gravel and relatively high velocities. Salmon 5 stations with side-scan sonar and fish wheels were established. Milling activity and mainstem spawning were evaluated with electrofishing and gill nets.Spawning surveys were conducted from RM 100 to 160. Chinook Studies Population estimates were determined from tag and recapture.The escapement in 1982 was far greater than in 81.They were near the 1976 levels.There was lots of milling in the canyon.Chinook were found above the Devil Canyon Dam site in Cheechako and Chinook Creeks. Sockeye Salmon We had a larger escapement of sockeye salmon in 82 than in 81.Most of the sockeye were found in the sloughs.Sockeye did spawn in Chase Creek,a tributary to Indian River and Prairie Creek in the Talkeetna 6 Drainage.Sockeye spawned in 9 sloughs between Talkeetna and Devil Canyon.We did document an early run of sockeye in the Talkeetna Drainage. Pink Salmon The escapement was less than average for an even year.Pink salmon spawn mainly in the tributaries.We found pink salmon using mainstem spawning sites in addition to slough habitats. Coho Salmon Coho salmon spawn mainly in tributaries.One mainstem site was located and coho were found spawning in one slough. No mainstem spawning areas were located below Talkeetna. Bering Cisco We had a much smaller run than last year.Fish were spawning in the same area (near Montana Creek)as they did last year.We had one repeat spawner from last year and fish were 3 and 4 years old. QUESTIONS Q Kevin Delaney (ADF&G)How many sloughs are there? A We have located 33 sloughs.10 are heavily utilized for spawning. Q Kevin Delaney (ADF&G)How many are mapped? A We have planemetric maps on 6 sloughs and will be able to assess access in these sloughs. 7 - - Q A Q A Q A Q A Q A Brad Smith (NMFS)How important are mainstem spawning sites? Some areas are heavily utilized.We may have 1000 fish in one area.The majority of the mainstem is not used. Ken Florey (ADF&G)How are the chum salmon spawning densities? Given the flow we had,how is the habitat utilization? We had good utilization of existing habitat.We are fairly close to capacity with 82 populations and flow conditions. Ken Florey (ADF&G)Is the utilization of the sloughs dependent on flow levels or are they density dependent? Our population estimates show an increased number of salmon in the system this year and fish moved faster in low water.Low levels kept fish out of the sloughs until late. Ken Florey (ADF&G)With regard to pulsing the discharge in the spring and during the spawning season,is there any evidence to support this concept?I realize that the studies are not complete enough to define pulses. We did observe fish passing into sloughs when flows came up in September,which lends some credibility to the pulse concept. However,both mainstem and slough flow increased. Are you going to do any winter food habitats study? We will be looking at the distribution of fish in slough and water temperatures will be monitored but we are not doing food habits.We will have some information on growth but the small number of fish scattered over the large channel makes sampling difficult. 8 Q Will you be able to tell turnover rate in overwintering habitats? A No.We don't have the resources to determine the relationship between fish overwintering in sloughs and fish overwintering in the mainstem. Q Brad Smith (NMFS)Does the large amount of milling behavior mean that fish will go upstream if they have the opportunity? A We think they ~ill as evidenced by the movement of chinook this year into Devil Canyon.We see a lot of interbasin movements and we have a sizeable population in Portage Creek. Q Has anyone taken a look at the parent year to see what the flows were? A We only had about 50 fish upstream of Devil Canyon and no scales were collected.We attempted to trap juvenile fish but didn't find any salmon. Q Lenny Corin (USFWS)Will you generate a new estimates of the grayling population in the impoundment? A Yes.We expect to have a substantial increase in the population estimate.We will have some information on Watana Creek and we have divided the Oshetna River into riffle pool reaches to refine our estimates. Q Ken Florey (ADF&G)Were there any age differences relative to the two runs of smelt? A Most fish were 3 yr old. 9 Q Ken Florey (ADF&G)Any repeat spawners? r"'~A No way to tell.Males have a longer spawning period than females probably 5 day as opposed to 1 day.The two runs appear to be genetically different due to size and weight. .- .... F"" Q Ken Florey (ADF&G)How long is incubationJ A We could not recover eggs but it is probably 2 weeks.ADF&G Interpretive Report Dana Schmidt (ADF&G SU Hydro).Our June report will integrate data from the various programs into a common base to determine the relative importance of populations at risk and the response to changes associated with natural variation.The report will be confined to the lower river and will integrate by species data on: 1.Adult migration and spawning 2.Embryo development 3.Freshwater rearing a.habitat selection b.response to changes in discharge and water quality 4.Outmigration timing It will address: o Relationship of behavioral response and changes in flow o Hydraulic change in habitat o Change in surfac-e area o Change in availability of cover and substrate o Response of chum and sockeye salmon embryos to thermal variation which presently exists in the habitat END OF SESSION MEETING SUMMARY EXHIBIT E WORKSHOP Water Use and Quality and Fishery Resources Section Holiday Inn,Anchorage,Alaska December 2,1982 ATTENDEES Name Organization Name Organization Jean Baldrige Woodward-Clyde Larry Rundquist Woodward-Clyde Larry Moulton Woodward-Clyde Eric Myers NAEC Brad Smith NMFS Bill Lawrence EPA Stackhouse USFWS Dan Wilkerson ADEC r~Garry Kevin Delaney ADF&G Paul Krasnowski ADF&G Michael D.Kelly AEIDC Bill Wilson AEIDC Mike Prewitt AEIDC Kevin Young Acres American Wayne Dyok Acres American Tony Burgess Acres American Dave Wangaard USFWS Gary Lawley Harza/Ebasco John Bizer Harza/Ebasco Paul Janke ADNR Tom Trent ADF&G Kevin Florey ADF&G Gary Prokosch ADNR Steve Zrake ADEC Nancy Blunck APA Tom Arminski APA Mary Lu Harle ADNR Dave McGillivary USFWS Patricia Lukens Acres American MITIGATION FRAMEWORK -Larry Moulton (Woodward-Clyde Consultants) Approach to mitigation was based on the USFWS and ADF&G mitigation policies which present the criteria and categories contained in Figure E 3.1 (Exhibit E).Keeping these criteria in mind let's review the impacts. -I - - - IMPOUNDMENT Impoundment Impacts: Lotic habitat will be innundated as a result of filling Watana Reservoir.Figure 2 shows the portions of the mainstem and tributaries innundated by Watana Reservoir.We believe that much of the grayling population presently occupying this habitat will be lost.The summer habitat in the streams seem to be fairly well occupied so few additional grayling could probably be accomodated in adjacent habitats.Grayling are not generally found in turbid lakes.In addition grayling may encounter difficulties in sucessfully incubating embryos spawned during reservoir operation.Spawning under reservoir operation will be difficult for most species.As the reservoir fills,sediments carried by the tributaries will settle out over the spawning areas,suffocating the eggs.Figure 3 illustrates how reservoir operation and biological activities overlap.The portion of the streams near the reservoir will be innundated by the reservoir filling schedule before the embryos hatch.The portion of the grayling population spawning in habitats above the 2135 ft level will not be affected by the reservoir filling schedule as these embryos would hatch before the habitat would be inundated.Table 1 indicated the miles of tributary innundated by the reservoir during the grayling spawning and incubation period.The amount of overwintering habitat is expected to increase. A population of Lake trout may develop in the reservoir but again production is expected to be limited.Figure 3 shows that most of the available spawning habitat will be dewatered during the winter before the lake trout embryos have completed their development.The spawning depths for lake trout.whitefish and burbot were taken from Morrow's Freshwater Fishes of Alaska.Some deep spawing lake trout may survive.The probablility of sucessful whitefish or burbot production appears slight. If these fish spawn in tributary channels the embryos may survive. We expect a little different situation in Devil Canyon Reservoir. The reservoir will innundate riverine habitat and the grayling populations occupying those habitats may be lost.However,grayling populations in these streams do not appear to be as large as those in the Watana Reservoir streams.The streams in Devil Canyon Reservoir are fairly steep and many appear to have migration barriers which will not be innundated by the reservoir. Q Silt load covering deposited eggs interfering with success.Also, what will the fish be feeding on? A Upwelling may clear some of the gravels.Loss of riverine habitat in impoundmeat zone with very little gained.Do not expect a productive littoral area and do not expect much food production. Q Is there an access problem if fish overwinter in the reservoir? A May actually improve accessibility as some fish barriers will be removed,e.g.falls on Deadman Creek will be inundated.Dollys have the best chance of surviving and may occupy reservoir habitats. Mitigation for the Impoundment Zones -Larry Moulton (WCe) Since the impacts for the reservoir can not be avoided,mimimized or rectified,compensation is planned for the lost resource.The best way to compensate these losses is with inkind replacement of grayling.We propose investigating the possibility of implanting grayling in barren lakes in the project area or possibly other lakes in southcentral Alaska if none are found within the vicinity of the project.Grayling could be raised in a hatchery and released in suitable lakes.It may be effective to deepen some lakes to provide overwintering habitat. Q Has the success of such a hatchery program been proven? A ADF&G has a grayling program at Big Lake Hatchery ------------------~----_._------~------------ - - Agency Comment -I'm familiar with the ADF&G program which is at Clear Ak. and it is my impression that the technology is not all that dependable.I don't believe it can be done on this scale. There were successful plantings in southeastern Alaska where the fish began reproducing on their own. ACCESS ROADS -Larry Moulton (WCC) The primary impacts to aquatic habitat expected to occur are related to road crossings and borrow pits.To the extent practical borrow areas for the access road have been moved to upland sites.Road crossings will be designed according to ADF&G fish passage criteria in accordance with the title 16 draft regulations.If desirable,the borrow areas near lake may be rehabilitated to provide aquatic habitat. Access to this area may result in an impact from the additional fishing pressures.Natural populations in streams and lakes could be protected if more restrictive harvest techniques and bag limits were placed on areas such as Deadman Creek.The lakes that are stocked with grayling provide a place for the guy who just wants to catch a lot of fish while natural streams could provide more of a quality fishing experience. road has been routed as far away from Deadman Creek as the corridor allows. Q Are you familiar with Copper Highway gravel pits?- Q A A Do you expect people to drive 200 miles to fish in a gravel pit? Yes,they drive that far now.We expect people to leave Anchorage or Fairbanks with a camper or Winnebago,pull up to one of these areas and fish for the weekend. Yes. Q Is this access discussion only for the Denali-Watana portion? A No both segments are discussed. Q What is the type of borrow material?Volume? A The borrow material should be relatively easy to get.We need about 200 surface acres for Denali-Watana and about same for Watana-Devil Canyon portion.We feel we can get this from upland sites and will not need to use any streambed material. Q If borrow areas are so easy to locate.how about alignment of the road? A They have done some realignment. Agency Comment -We have not yet quantified loss.but we don't think that there is any way to raise the number of fish that we are talking about. There is no compensation for unique experience that can be had today at the mouths of some of these streams. DOWNSTREAM IMPACTS-Jean Baldrige (WCC) Before we begin on the downstream impacts I would just like to take a few minutes to discuss our approach to assessing downstream impacts and where we are in the process.Our approach is based on habitat.We looked at areas where the project would alter habitat conditions.Then.we evaluated the changes to determine if they would impact the fishery resources.This is basically a sequential process.First we have to know what the project area is and how the system works.Then we can overlay the project operating scenario and determine the project impacts.After assessing the impacts we develop a mitigation plan to address the expected impacts. Where are we in this process?Well,we have a good general understanding of how the basin works,what the processes are,the general distribution,and timing of the fishery resources.We know what habitats are important.We have identified generically,the type of impacts likely to occur and we have developed a conceptual approach to mitigation and established some priorities.We have some concepts regarding mitigation features.Larry Moulton will talk more about mitigation later today. In reviewing the physical processes in the basin as Wayne Dyok and other talked about yesterday,most of the changes will occur in the Talkeetna to Devil Canyon section.We expect most of the changes to occur under the filling and operation of Watana.Devil Canyon Dam may result in slight increases in the types of impacts which will occur under development of Watana. Q A What is filling time for the Devil Canyon? About a month.Downstream flows would be maintained at 5000 cfs. (Ed.note -actual filling time from elevation 1135 to 1455 will be in the order of 5 to 8 weeks) Q Why stick with a 5000 cfs value?Do we know enough to say that's what we need? ..... A That is what we have had to work with.We feel that in the 8-10 yr period in which Watana alone would operate,a new fishery habitat will develop and substantially changing the established regime will hurt that new fishery. WATANA FILLING -Jean Baldrige (WCC) Filling Watana Reservoir is expected to take three years.This figure presents a comparison of streamflows:expected for filling Watana reservoir.I have combined parts of the secondc'and third years to show the months of the greatest changes expected.Many of the changes expected during the open-water season will occur during the initial filling of the reservoir.We expect changes in: o Streamflows o Water quality o Water temperature Mainstem and Side-channel Habitat Mainstem and/side-channel habitats will be directed influenced by the proj ect. o Outmigration Break-up will be diminished which may affect outmigration.Sufficient water will exist to transport fry downstream but both the rising water levels and temperatures that may stimulate outmigration may not occur under post project condition. Q Asked whether the reduced flows are indeed sufficient for the fish passage. A Yes,for river migration. o Chinook inmigration There should be sufficient water to pass fish upstream.Studies on navigation by the ADNR show that there will be depths of at least two feet in the shallowest cross-section which is located between sloughs 8 and 9. Chinook will also be able to gain acess to tributary habitats under filling flows as R &M discussed yesterday.Chinook are also expected to be able to ascend the canyon and utilize tributary habitats below the Watana dam. Q These effects during filling -what about operation? A Similar effects. - --Q A Would you really get a decrease in velocity through Devil Canyon. Yes,due to the rectangular shape and the confined nature of the canyon.we expect that when we decrease the discharge,the velocities will be reduced.There will still be high velocities in the cayon but chinook should be able to pass. - .... - o Spawning season A few spawning areas were located in mainstem and side-channel areas.Lower flows during the spawning season may adversely affect some mainstem and side channel spawning areas.Many of these areas are located on the margins of the system in areas protected from high flows.Because these habitats are located on the perifery of the system they are more susceptible to dewatering. o Water temperatures During the second year of filling we expect water temperatures in the range of 5 to 6 °c during the summer time.Temperatures in this range may deter adults form entering the system.If they do enter the system, the cool temperatures may retard sexual maturity and delay spawning activity.Low water temperatures could affect resident and juvenile anadromous fish by retarding growth or by causing fish to move into warmer waters in the tributaries and sloughs. Slou~h Habitat Slough habitats will be slightly buffered from changes in the mainstem,but we expect some adverse impacts in these habitats.In the spring.under the filling flows we will not have the kind of break-up and flushing action we have now.However.we will still have some increase in slough discharge and stage from the increase in local surface runoff as the snow melts and the rains come.This may provide sufficient stimuli for the fry to outmigrate. In August under 12,000 cfs we may have some passage problems as Woody Trihey discussed yesterday.This afternoon we will discuss ways to rectify this situation.We may also see some reduction in the areal extent of upwelling and perhaps the rate of upwelling.As the backwater effects from the mainstem are reduced,some of the lower spawning areas may be affected.A decrease in depth may reduce the amount of spawning area available as well as affect holding areas. Another result of regulated flows would come from increased beaver activity.Beaver dams have already caused some passage problems.At slough 8A,the beaver dams precluded upstream migration until the flow levels increased in September.Then with the additional stage and backwater effects the fish were able to pass. Q What is the source of flow and ice formation in the slough. A Right now the sloughs form a thin ice cover over much of their· length.At the slough mouths,the ice may resemble the ice cover in the mainstem in its thickness.At slough 8A ADF&G observed that the slough was overtopped as the ice front proceeded upstream past the slough.The discharge increased to 150 cf s.In the spring,the ice melts off the sloughs earlier than break-up in the mianstem.In April the slough are open and free flowing. Q Is there a spawning population in these sloughs?What velocities are we talking about? A We don I t expect that the velocities are high enough under ice formation to cause scouring. Comment -Acres clarified the path length of the groundwater flow that influences upwelling on the slough picture. Groundwater moves along the downriver gradient and not really cross wise through the island. Tributaries The only portion of the tributary which will be influenced by the project will be the tributary mouths.As in slough habitats,the mainstem causes a backwater to form which provides passage and rearing habitat for residents and juvenile anadromous species.R &M performed an analysis that indicates that,with an exception of three,the tributary mouth will not become perched.The backwater zone may be slightly reduced.Tributary habitat above Devil Canyon will become available to chinook salmon as we discussed earlier. -Q A Of those streams that are going to be perched,why is it that they will perch. Size of stream bed material. - WATANA OPERATION Under operation,the flows will be a bit higher in the spring and fall,definitely higher in the winter and about the same much of the summer.We will have greater control on the downstream temperatures.In addition we will reduce the number and magnitude of floods in the system. Presently we have an annual flood of 50,000 cfs.Under operation that annual flood will be about 13,000.We will also have a change in the sediment transport in the system.Right now the system carries lots of sand suspended in the water.You can hear it hit your boat.The reservoir will remove the sand.The river will pick up some sediments below the dam and will carry some sediment but it will be much clearer than the existing conditions. Because of these physical changes we expect rearing conditions to improve in mainstem and side-channel habitats.We expect increased benthic production from improved light penetration and reduction of suspended sands which presently sandblast the substrate. Q Is there a seasonal consideration of your discussion with regard to increased benthic production in mainstem habitats? A Mainly summer. Winter Conditions Discharges will be higher in the winter.Water temperatures will also be increased.Upstream of Portage or Sherman,temperatures will be 2 to 4 °c at the dam outlet thus there would be no ice on that portion of the river.Warmer water temperatures are expected to benefit overwintering fish by reducing mortalities associated with freezing.Stable flows will prevent dewatering of overwintering habitat and spawning areas available under the postproject summer flows.Warmer water temperatures may alter the embryo development rates.Temperature increases may result in early emergence,which has been linked to decreased survival.If these fish move downstream,they will encounter OOC water in the Chulitna and may experience thermal shock.Chum slamon would be less susceptable as they select areas with upwelling,which would buffer the embryos from mainstem temperature changes.The suspended sediments will increase slightly during the winter. Downstream of Sherman,we will have an ice cover.Here again, increased winter discharge is not expected to adversely affect rearing fish.We may have some increased velocities but we expect there will be sufficent areas along the margins of the river and in pools for fish to overwinter.Juveniles spend much of their time in or near the substrate so mean column velocities may not be as important to them in the winter as they are in the summer. Sloughs The change in ice processes will affect slough habitats.Upstream of the ice front we will have open-water condition.As Tom Lavender discussed'yesterday we will have less stage than under the present ice cover.Since winter and summer discharges are virtually the same,spawning habitat available under the post project summer flows should be maintained by the winter flows. Downstream of the ice front we expect an increase in stage over pre-project conditions.This stage is expected to increase sufficiently to overtop the sloughs at the head end which would allow cooler mainstem water to enter the slough system.This would reduce ~urface temperatures in the sloughs and may adversely affect the quality of overwintering habitat. If this process causes aufeis formations in the upper portion of the sloughs,water temperatures in the sloughs may be reduced well into June. No flushing flow would be available to remove the ice and it would have to melt.If cooler water temperatures persist through the spring it could adversely afffect nursey areas for emergent fry. Q A .... Q A ,~ Q A What river mile is Watana?So we are talking about 30-55 miles of open river under post-project winter ice conditions. Yes. What temperature is causing this?I thought the ice front would be at Talkeetna. Under the operation of Watana we expect the ice cover to be between Portage Creek and Sherman.Under the operation of Devil Canyon we expect the ice cover to be somewhere between Sherman and Talkeetna. Do we have any idea of relative percentages of overwintering in mainstem vs.sloughs. Do not have percentages but both habitats are being used. --Q Aren't we also seeing a lot of stranded river ice now? A Yes,but they are much smaller than an aufeis field. Q Juvenile fish coming out of tributaries -will there be enough water to get back into sloughs? A Outmigration from tributaries occurs all summer long. Q What do Indian and Portage contribute to flow. A The contribution is relatively small. A (Acres)Gave some numbers. Q When we hear discharge at Gold Creek,that is not the discharge at Watana. A That is correct.We will have immediate feedback of Gold Creek streamflow data to modify releases at the dam. Q Trying to figure out slough access comments in FERC -Exhibit E (Chapter 2).What is most sloughs? A Access not a well-defined factor on a slough-by-slough basis.Fish did get into many sloughs under 12,000 cfs but access was difficult. } Wayne Dyok (Acres)presented some information on ice processes in sloughs. Reiterated that presently the ice front causes mainstem water to flow through the slough and the mainstem ice cover progresses up the slough. This is probably of short duration. Q Ground water seeps small -Will large flows cause scour? A We don't expect they will but we don't know. Q Won't this have an effect on changing the upstream berm? A They may change the height of the berm at the upstream end.We will have to evaluate this. ..... ...... DEVIL CANYON Filling of Devil Canyon will be a short time,5 weeks.We reported 5 months in the Exhibit E.Filling will be accomplished in the winter. Downstream discharges will be maintained at 5000 cfs.Under the operation of Devil Canyon you can see that we have small increases in the percent change of streamflow (Figure).We do not expect these changes to result in new impacts but the magnitude of impacts discussed under the operation of Watana will be slightly increased.One notable difference as we mentioned earlier,the ice front will be between Talkeetna and Sherman after Devil Canyon comes on line. DOWNSTREAM OF TALKEETNA Let's just take a brief look at the system below Talkeetna.You can see here at Sunshine station (Figure)that the changes are of a smaller magnitude.In addition we do not expect much difference in either the temperature regime nor the sediment transport processes • Moving down to Susitna station we see even a further dampening of project effects.The Eulachon will be in the system in May which has a decrease of about 10 per cent.Changes of this magitude are not expected to significantly affect the Eulachon spawners. -Q A Have you considered the relatively short time that the Euluchon are in the system and does mean monthly represent the situation? It may not but under peak flows the percent reduction would be less. This will be looked at when the data is available.We will be trying to get into daily and weekly streamflow values for all fish and the entire system if appropriate.AEIDC will be looking at this in their quantitative impact assessment. Q Processes will remain the same as under Watana,just be more of it. A Wayne Dyok (Acres)Yes. Q During filling and operation may there be large slides into reservoir affecting water quality downstream. A There will be some slumping especially under the initial filling, but we do not expect much effect downstream.The slide would contain large soil particles which would probably settle out in the reservoir. Q With the loss of some sloughs can something be done to mitigate by making new sleughs or are they a total loss. A We do have some ideas on slough mitigation which we will discuss now. Q What level of turbidity do you expect downstream in winter months? A Slightly higher than now. Q What is that comparable to under present conditions up-and downstream of Talkeetna? A Similar to those experienced in September. Q How is this all going to be compiled into a composite impact? A (WCC)(ADF&G-SuHydro)and (AEIDC)will be doing this in the next several months. Q Will also have to integrate the terrestrial and other studies. A There is coordination between the different groups. Agency Comment -ADF&G had a good point on cumulative impacts. .... - ".,., - !"'" I Q 1 1 m not happy with the philosophy of "We have only a 10 percent change and therefore we don't expect alot of impact."Many of our species already at the edge of a range and 10%can push it over the edge. A We are still trying to refine and define these problems. Wayne Dyok (Acres)made announcement regarding handout • Larry Moulton (WCC)announced typo changes on Table E34. MITIGATION -Larry Moulton (WCC) Water Temperature The muliple level outlet will provide some temperature control during operation and the last year of filling.Temperatures during the second year of filling are still a problem.We may be able to solve this problem by including a low-level intake.This would also give us more temerpature control during the spring and fall when we may want to provide warmer or cooler water.The engineers are presently looking into this. Streamflow Under the present operating senario,we can't avoid all impacts to the fish,but we may be able to rectify some of these impacts through habitat modification.One concept is through slough modification.(Figure E 3.9).We would modify a slough using downstream control structures to increase the depth and allow fish passage.The upper end of the slough would be diked off to prevent the mainstem discharge from entering.A gate with a pipe would allow us to have flow through the slough for flushing or for outmigrants. Q Do you have a generic price to go along with the generic design? A $3-$4 x 10 6 per 30 million eggs. Q How many would be built. A However many are required to mitigate the loss. Q Have you compared this to hat~hery costs. A Yes,It appears to be about ~the cost. Q A Who would operat~the valve? Manual operat~on. Q You are thus proposing to design an artificial slough? A We wouin use an existing slough. Q Do the flow control weirs get removed for flushing? A They will be dropped or laid back but we haven't worked out the details yet. Q How would you get to these areas for maintenance? A Most of these areas will be near the existing railroad. Q Will the juvenile chinnok and coho be able to use the sloughs for overwintering? A We presently have no mechanism for them to get in but can consider it. Q When holding the chum,do the coho and chinook feed on the chum? A They probably would. Agency Comment - I think they would really be able to chow down since the chum would be held in confined areas. Q A How is the time of emergence span going to be accounted for on the release schedule. We don't have that information yet as to when the emergence time is and what flows would be required. - Q We tried feeding chum in Cold Bay and the fish wouldn't leave.How are you going to get the fish out? A We were proposing to feed the fry only if we had early emergence and downstream conditions were not suitable.With the recent results of groundwater studies it looks as though we will not have to feed the fry. Project Comment -These are proposed mitigation measures and combined with flow regulation,we have some flexibility.We will probably use a combination of mitigation techniques.Some sloughs may not require modifications,others may require a structure at the entrance to help the fish get in,others may require only the berm at the head end.The goal is to maintain as natural and passaive a set of modifications as possible. Agency Comment -There are no spawning channels in operation in Alaska. The ones at Fourth of July Creek in Seward were washed out.I think you will probably have a lot of problems with these. Agency Comment -Beaver will love these channels and will be hard to control. Q A Are we going to talk about priorities. emphasis on alternative flows. We have been covering this. 1st is flow regimes 2nd is modification of sloughs 3rd is hatchery. I'd like to see more Agency Comment -Seems like these slough modifications are getting down to the bottom of the list. Agency Comment -We have already covered flows.These plans are Ita joke". I don't think they will work.We might as well be looking at hatcheries. Q Do you know what the effects of time would have on these plans. River changes abandoning slough. A We would not ~roposea mitigation that would be abandoned. Acres Comment -Ice scour is not a problem under project operation and we do not expect the river to change its channel. Q What is the objective of this slough modification program? Q Are you trying to create new habitat or maintain existing habitat? A We are trying to maintain the existing habitat. Q Is the information that ADF&G and AEIDC will provide going to be helpful in defining which areas will need this mitigation? Agency Comment -That's right -if it is not broken,don't fix it. A Yes definitely,The information on habitat relationships and impacts will prOVide the basis for mitigation.This is a sequential process.We are going to undertake a feasibility study to determine if these concepts are practical.We need to understand better how specific sloughs work and then design a specific mitigation for each slough. liQI'!l'II, - - DEMONSTRATION SLOUGH -Jean Baldrige (WCC) First,I would like to review the problems in slough habitat under operation of the project.Through·slough modification we would attempt to resolve these problems: o Access for adult salmon o Winter thermal regime (overflow from mainstem) o Reduced upwelling o Sedimentation o Vegetation encroachment o Beaver activity The objective of the demonstration project is to test the feasibiliy of slough modification as a mitigative measure for the Susitna Project.We propose to modify a slough to demonstrate that we can provide access and/or enhance upwelling. We have started a site selection process to find a suitable area to use.At the end of October,Woodward-Clyde in conjunction with Fish and Game conducted a reconnaisance to find some candidate sloughs.We established some criteria to assist us in this selection. o Marginal fish use o Ground water upwelling o Suitable substrate o Surface water source o Adequate water quality o Accessibility for heavy equipment We are in the process of screening the sloughs according to this criteria.We hope to identify likely candidates to begin a baseline data collection program on this next field season and we will then be able to actually modify a slough after that.Presently we don't understand [specific]slough processes well enough to be able to design a modification progam that we know will work. Acres Comment -With regard to the sloughs,we have a pretty good handle on the processes.The ~jor missing link is applying the processes to each of the sloughs individually to get the impacts to each slough.A few sloughs have been studied and results will be available.We may find that no modification is necessary for some sloughs,minor modifications for others, and major modifications (artificial channels)to others.Is it worth doing the major channel modification?We don't know enough right now to decide. ADF&G (Su hydro)Comment -Exhibit E Has been prepared on one flow regime. Mitigation is based on one operational flow.One problem to be dealt with is avoidance.Flow may be available for avoidance but it may not be prudent to go with that flow and the flow regime will still be under negotiation.Our studies and AEIDC's models will help address the question of flows. Q Is slough modification a technique proposed to the agencies or is this the mitigation proposed in Exhibit E? A This is a proposed mitigation for the project. Q We aren't going to know until we try it.If it doesn't work what happens since the project will be well along the way? A Most FERC licenses stipulate a certain acceptable limit of escapement or production that is monitored during construction and operation.If the mitigation does not work then we can undertake additional mitigation. Agency Comment -Whenever we are mitigating,we have to mitigate whatever potential there is under natural patterns. Agency Comment -Mitigation policy has been established but a program is needed to outline a plan for monitoring. A It's included in the Exhibit E. mitigation plan. Monitoring is part of the Q Is the slough modification proj ect going to look at improving an existing slough. A Yes. Q Are you using the fish to see the effects of mitigation.You aren't doing anything about fish production to evaluate the impacts or effectiveness of these modifications.How is fish production being evaluated? A We do not evaluate the habitat in terms of x number of coho units. We are constrained to use the physical parameters,we identify current conditions and try to maintain those conditions.The measure of success of those modifications would be in terms of escapement or fry production as gathered through a monitoring program. - Q A I didn't get the idea how conceptual are the mitigation plans that are proposed in the Exhibit E.Today's presentation has cleared this up.No one wants to see hatcheries on the Susitna River except as the last alternative but why aren't hatcheries mentioned in Exhibit E.Don't you want to include some hatchery program to address what can be done if the other mitigation prove not to work. What would be the senario with a hatchery? Krammer,Chin and Mayo have just completed a hatchery siting study. FRED division is looking at upper basin enhancement possiblities without the project. ~. Comment -We have already selected a case that allows release such that hatcheries are not required. Q What is your perception as to how FERC looks at these mitigation approaches.What is your understanding of these approaches.Are they put in to placate the agencies? A We can not state what FERC will do. ACHS Comment -FERC has not reacted to anything proposed to them yet.That is the way FERC works -they will not plan the project for the Alaska Power Authority. Alaska Power Authority Comment -We are dealing with a continuous series of mitigation schemes and a continuous series of flow regimes to deal with changes in a continuous series of habitat types. Q Are we where we should be on the mitigation plans for the FERC process? A Regs say that a workable design drawing is required,but definition of a design drawing is vague.Design drawings usually not required except where an integral part of the dam,though schematics for systems usually are included. Agency Comment -It is a continuum;they may request more data or accept it as is.We may feel that we are not very far up on the continuum,but FERC may not be concerned about this.They may require that problems be worked out between the Alaska Power Authority and the agencies and return to FERC with resolution.How is FERC going to properly review the Exhibit in the short time frame? A This is a Draft review. Q What is FERC going to come back with. A We don't know. ...., - - Wayne Dyok (Acres)gav~,a handout. John Hayden (Acres)thanked everyone. MEETING ADJORNED r r L r ISSUED TO 2219 tit", l<';".,r-"",,-..q Before the Federal Energy Regulatory Commi ss ion LIBRARY HABITAT DIVISION ALASKA DEPT.OF ,FISH &GAME 333 Raspberry Road Anchorage,Alaska 99502 OflfHO TK 1424 A4 B44,,:!l - rI r r r r~ ,.....'. ! ADF&G HAB!TAT LIBRARY',,' 1~1J11J1111'11'"JIIII~"llffllllll/"jjj"III'III'IJIIIIII"III~mlll11111111, 32345000084500