Loading...
HomeMy WebLinkAboutWatana dev winter 1983 geotechnical exploration program vol 2 1983~-.-_.---.------.-- OB'-t .iliASRA RE~OlmCES LnrRAR-f; u.s.DEI'T.OF'e-;-TETIOR SUSITNA HYDROELECTRIC PROJECT WA TANA DEVELOPMENT WINTER 1983 GEOTECI-INICAL EXPLORATION PROGRAM VOLUME 2 APPENDICES SEPTEMBER 1983 SUS/TNA JO/NT VENTURE I...---_ALASKA POWER AUTHORITY_---.-I T\\ \11d.S .,$8 A?.3 "1:t.-no.-:);::' SUSITHA HYDROELECTRIC PROJECT WATANA DEVELOPMENT WIBTER 1983 GEOTECHBICAL EXPLORATION PROGRAM VOLUME 2 APPENDICES Prepared for the ALASKA POWER AUTHORITY BY HARZA.-EBASCO Susitna Joint Venture r I September 1983 ARLIS Alaska Resources Library &Information Services AnchoragelJU~~ka .... I r-' i r TABLE OF CONTENTS VOLUME 2 APPENDICES TABLE OF CONTENTS -- TITLE/SECTION APPENDIX A GEOPHYSICAL EXPLORATION • • • • • • • • . PAGE A-I 1.GROUND PENETRATING RADAR (GPR).. • . 1.1 Data Acquisition 1.2 Conclusions •• A-2 A-2 A-3 - 2.SEISMIC REFRACTION 2.1 Data Acquisition .••.•• 2.2 Data Reduction and Analysis 2.3 Interpretation 2.4 Conclusions •• A-3 A-3 A-4 A-5 A-5 2,,4.1 2.4.2 2.4.3 Downstream Cofferdam Foundation • • • • Centerline and Upstream Foundation Area Upstream Cofferdam Foundation A-6 A-7 A-8 3.BOREHOLE GAMMA LOGGING 3•1 D;H a Ac qui si ti on •••.• 3.2 Analysis and Interpretation. 3.3 Conclusions •.•.••••. REFERENCES A-8 A-8 A-8 A-9 A-IO 4.TABLES Seismic Refraction Survey -River Channel Tables A-I through A-II _. 5.FIGURES Location Map Ground Penetrating -Radar Profiles Seismic Profiles Gamma Logs i A-I A-2 A-3 othrough A-12 A-I3 through A-43 VOLUME 2 APPENDICES TABLE OF CONTENTS TITLE/SECTION APPENDIX B DRILLING AND SAMPLING METHODS 1.HAMMER DRILL RIG 1.1 Percussive Hammer 1.2 Rotary Drilling. 1.3 Additional Equipment •• PAGE B-1 B-1 B-1 B-3 B-4 2. 3. 4. ROTARY DRILL RIG • • . . • SAMPLING DRILLING PERFORMANCE B-4 B-5 B-6 APPENDIX C BORING LOGS C-1 ., <7 1.BORING LOG NOMENCLATURE •0 • ••e C-1 1.1 Unified Soil Classification System C-7 GEOLOGICAL LOGS 2.BORING LOGS 2.1 River Channel 2.2 Relict Channel ii ..... VOLUME 2 APPENDICES TABLE OF CONTENTS TITLE/SECTION APPENDIX D LABORATORY TESTING 1•PROCEDURES PAGE D-l D-l .... - 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 Sample and Control Processing ••••••••• Particle Size Analyses • • • • • • • • • Atterberg Limits (Liquid and Plastic Limits)•• Moisture Content ••••• Organic Content • Specific Gravi ty Compaction Tests Visual Classification • TABLES D-l D-2 D-2 D-3 D-3 D-4 D-4 D-4 2.LAB TEST SUMMARIES 2.1 River Channel 2.2 Relict Channel 3.GRADATION CURVES 3.1 River Channel Main Dam Upstream Cofferdam ~Downstream CofferdamI Portals - 3.2 Re:lict Channel iii r I I i r I r Ir r ! i -- I APPENDIX A -GEOPHYSICAL EXPLORATION 1.GROUND PENETRATION RADAR -RIVER CHANNEL 1.1 Data Acquisition 1.2 Conclusions 2.SEISMIC REFRACTION SURVEY -RIVER CHANNEL 2.1 Data Acquisition 2.2 Data Reduction and Analysis 2.3 Interpretation 2.4 Conclusions 2.4.1 Downstream Cofferdam Foundation 2.4.2 Centerline and Upstream Dam Foundation Area 2.4.3 Upstream Cofferdam Foundation 3.BOREHOLE GAMMA LOG -RIVER CHANNEL AND RELICT CHAN I\l EL 3.1 Data Acquisition 3.2 Analysis and Interpretation 3.3 Conclusions 4.TABLES 5.FIGURES - APPENDIX A GEOPHYSICAL EXPLORATION The purpose of the winter geophysical program ln the river channel at the Watana damsi te was to provide overburden·and bedrock foundat ion information in the area between the upstream and downstream cofferdams. The data obtained from this program will be used for rapid determina- tion of subsurface conditions,correlation between borings,and to determine general stratigraphy at greater depths than those penetrated by borings in the river channel and in the relict channel area.Ground penetrating radar (GPR),seismic refraction,and borehole gamma logging methods were employed.The radar and seismic refraction surveys were run by a four-man field crew under the di rect ion of a Harza-Ebasco geophysicist.Two members of the team and the equipment and ins tru- - ments were provided by Harding Lawson &Associates. logging was done by a Harza-Ebasco geophysicist. The boreho Ie .- i .... The ground penetrating radar was used as a rapid reconnaissance tool to del ineate shallow overburden depths to bedrock ln the n ver channel, thereby allowing the selsmlC refract ion and dr i 11 ing programs to be used where they would be most effective.GPR was also used to deter- mlne lce thicknesses and rlver channel profiles to aid ln the safe movement of men and equipment over the frozen river surface . The purposes of the selsmlC refraction was to provide seismic sect ions delineating overall depth to bedrock in the river channel. A-I Borehole gamma logs were run in all open boreholes to assist in hole- to-hole correlations.The ultimate goal of the geophysical program was to provide a better understanding of subsurface conditions above bedrock. 1.GROUND PENETRATING RADAR (GPR)-RIVER CHANNEL 1.1 Data Acquisition The GPR survey was perfromed with a Geophysical Survey Systems,Incor- porated (GSSI),SIR-7 radar system.The system consists of a power supply,control unit,EPC graphic display recorder,and two trans- mitting/receiving antennas.All instrumentation was mounted in a Nodwell FN-20 flatbed snow vehicle and the antenna was towed behind. IJ!I!1 I i Two antennas were used for this survey: of 120 MHZ and the other of 300 MHZ. one with a central frequency The GSSI system uses radar technology to obtain a continuous high reso- lution electromagnetic profile of the subsurface.The depth of pene- tration is dependent upon the electrical properties of the subsurface materials and the frequency of the radar antenna employed,and may penetrate several tens of feet.The penetration depth was limited to approximately 15 feet for this survey. Figure A-I shows the locations of the fourteen radar profiles obtained between January 23,and January 26,1983.The profiles total 8486 lineal feet of coverage.The profiles that cross the river at the up- stream and downstream cofferdams and at the dam centerline were located by utilizing.on the ground,general topography.Profiles at other locations were positioned by taking bearings with a Brunton compass and making use of the survey reference marks available along with the A-2 - - general topography.Measurements along each line were made with either a tape measure or hip chain. For this survey,dielectric constants of 30 for saturated material and 81 for water were assumed in order to produce the profiles presented in Figure A-Z. 1.2 Cond us ions The primary objective of the radar survey was to locate local areas in the channel where overburden is very shallow (less than 15 feet below the surface). Since the bedrock surface was 1.n most instances greater than 15 feet the radar survey was primarily utilized to ascertain ice thickness and river bottom profile information.These data were used in constructing a topographic map of the surface of the river alluvium.The radar data was also used by the 1.ce building and survey crews to check 1.ce condi- tions in questionable areas of the river channel prior to moving equip- ment over the ice.The information was thus utilized in planning the l- I routes to be taken by the hammer drill rig during its river channel operation. 2.SEISMIC REFRACTION -RIVER CHANNEL 2.1 Data Acquisition The se1.sm1.C refraction surv~y was conducted with a Geometrics ES-12l0 l2-channel signal enhancement seismograph and 4 hertz Mark Products vertical geophones.The energy source was Kinestik explosives;Atlas - Staticmaster electric blasting caps were used to initiate the explo- s1.ons. A-3 Ten reversed refraction lines were run totalling 8785 lineal feet of geophone coverage as shown in Figure A-l.Each seismic line contained from one to three spreads of 12 geophones each with an interval of 50 feet between geophones.Shorter geophone spacings were used where necessary. Generally,two shots were detonated at e'ach end of each spread at dis- tances of 10 to 25 feet and 200 to -600 feet from the end geophones. All geophones were placed either on grounded ice or float ing river ice due to the seasonal conditions. 2.2 Data Reduction and Analysis During the seismiC surveYing the presence of a high speed ice surficial layer acted to mask seismiC arrivals from the slower velocity'of the underlying all uvial depos its.It was ant ic ipated that the bedrock velocity would be sufficiently faster than the ice so that it could be detected.This was the case with the first seismic arrival times from the ice preceding and obliterating the slower arrival times from the underlying river sand and gravel deposits,therefore,the seismiC velocity of the saturated alluvium was never actually measured.How- ever,the bedrock velocities were sufficiently faster than ice velocities so that with a long offset between the shot and geophone spread,seismic energy from the bedrock surface was detectable.Con- sequently,refraction profiles were run parallel or oblique to the river channel to take advantage of the long offset method. Compressional wave (p-wave)arrival times were determined by observing the first break on each of the 12 horizontal wave traces recorded by the seismograph.These arrival times were then plotted against the horizontal distance from the shotpoint to the receiving geophones and grouped by apparent refractors.Standard velocity/intercept time A-4 (Dobrin,1976),velocity/delay time (Cummings,1979;Hagedorn,1959; Scott et aI,1972),and ray tracing (Scott et aI,1972)techniques were applied to these data to provide P-wave velocities and thicknesses for refractors. 2.3 Interpretation- Due to the surface ~ce layer,veloc ity data were not obt ained for the saturated alluvium beneath the river bot tom.In order to make depth calculations,it was assumed that the velocities for this material range between 6000 and 7000 fps velocit ies for the alluvium prov ided the best fit.In those exceptions,6000 to 6250 fps velocities were used,which were still within the expected range. Seismic velocities of 14,750 to 18,000 fps.were interpreted as indica- tive of bedrock. 2.4 Conclusions Seismic profiles for S83-l and S83-3 through 10 are presented ln Figures A-3 through A-12,and show the interpreted bedrock elevat ions and assumed velocities in feet per second for the alluvium and bedrock. Also shown are the shotpoint positions,time-distance data,and depths to bedrock measured by hammer drilling,and seismic line intersections. Time-distance data for each se~sm~c line are shown ~n Tables A-I through A-IO.A summary of the velocities ~n the alluvium (Vl)and bedrock (V2),and the depth to bedrock are presented ~n Table A-ll. These velocities do not include those of lce or ice-bonded soils. There ~s generally good seismic profi Ie sect ions "... - ,,---------_._---_._---------_._------- correlation between borehole data and where geophone spreads actually cross A-5 the the locat ions of the borings.Typically the variat ion ~n the depth to bedrock between these sets of data ranges from 2 to 15 feet. The upstream end of 883-10 does not agree with data from DH-3,wh ich was drilled during previous exploration.This hole shows bedrock at 78 feet below ice surface while the seismic data indicates depths 20 to 30 feet deeper in this vicinity.It is'quite possible that extremely irregular bedrock topography in this location has distorted the seismic data. In general,the depth to bedrock was shallow (less than 25 feet)along the north shore at the downs tream cofferdam,moderately deep (60-80 feet)~n the center of the channel at the upstream and downstream cofferdams and at the ma~n dam,and very deep (greater than 150 feet) in localized areas between the main dam centerline and upstream coffer- dam.A discussion of each major seismic line follows. 2.4.1 Downstream Cofferdam Foundation ., I ProE les 883-1 and 883-3 are al igned along the north shore.Profiles S83-4 and 883-10 are oriented parallel to the course of the r~ver channel and are near the center portion of the channel. Profile 883-1 shows relatively shallow bedrock (2 to 27 feet)with a se~sm~c velocity of 15,300 fps.The apparent dip of the bedrock sur- face is to the east.An attempt to gather seismic informat ion across the r~ver channel along refraction Line 883-2 was made,but because of the short shore to shore distance,only direct arrivals through the river ice were recorded. Line 883-3 indicated a single velocity layer with an average seismiC velocity of 14,500 fps.This could be interpreted as bedrock at the A-6 - ,... - ,I""'" ".,., surface.Borehole data,however,indicates that rock 1S over 20 feet deep near this line.5ince the velocity 1S between that of 1ce and those noted as bedrock on other lines,it was concluded that the alluvium under this line 1S frozen or partly frozen. Profiles 583-4 and 583-10 provide subsurface information below the cen- ter of the river channel.The depth of'bedrock averages 75 feet and the se1sm1C velocity ranges from 15,000 to 17,000 fps.Both profiles indicate that the apparent dip of the bedrock surface is to the south. 2.4.2 Centerline and Upstream Dam Foundation Area Profile 583-5 intersects the centerline of the proposed Watana Dam, Profiles 583-6 and 583-9 are centered 900 and 1600 feet upstream (east) of the centerline,respectively.All three profiles are oriented. parallel to the course of the river and within the river channel. Profile 583-5 shows an undulating bedrock surface with an average depth of 70 feet.Bedrock velocities (V2)range between 14,750 and 18,000 fps.Bedrock begins to dip moderately to the east 1n the eastern prot ion of the profile.The lateral change in bedrock velocities could be caused by fracturing or shearing of the bedrock. Profile 583-6 could not be handled by convent ional computer mode 1 i ng techniques:,probably because of severe distort ion of the field data by near-vert ieal disp lacements 1n the bedrock topography.A de lay-t ime method (Cummings,1979;Hagedorn,1959)was app 1 ied to the arrival times.The,model indicates a vertical displacement of 80 feet in the bedrock surface and bedrock may be as much as 170 feet deep at the base of the scarp. A-7 Profile 883-9 shows a deep bowl-shaped bedrock surface.The maX1mum depth to rock is 162 feet;the seismic velocity is 15,500 fps. 2.4.3 Upstream Cofferdam Foundation Profile 883-7 intersects the centerline of the upstream cofferdam. Profile 883-8 1S located 550 feet upst'ream of the centerline and crosses the northeast portion of Profile 883-7. Both profiles show a slightly undualtirtg to level bedrock surface with an average depth of 65 feet and a velocity of 16,500 fps. 3.BOREHOLE GAMHA LOGGING -RIVER CHANNEL AND RELICT CHANNEL 3.1 Data Acquisition Natural gamma logs were run 1n all open boreholes drilled during the winter program using a Mt.Sopris Model II borehole geophysical logging system.With the except ion of DH83-4,all boreholes were logged through 2 inch PVC;DH83-4 was steel cased to 60 feet and open below 60 feet.Eight of the boreholes logged were located in the relict channel and 23 were 1n or near the river channel.The locations of the river channel boreholes are shown in Figure A-I. shown on Figures A-13 through A-47. 3.2 Analysis and Interpretation Individual gamma logs are The natural-gamma logs were all run at a speed of 10 feet/min.and at a time constant of 5 cps (counts per second)for good definition of gamma anomalies.Chart deflection was set at 5 cps per division horizontally and 10 feet per inch vertically. A-8 - Gamma logs of adj acent ho les were analyzed by matching log int erval s having the same amplitude and similar anomaly signature.Those matches were then checked against the borehole sample logs for geologic their reasonableness according to standard geofluvial processes ..... identification.Individual gamma/litho units were then checked for - 3.3 Conclusions The gannna ray profile along se~sm~c line DNA indicates that the gamma ray log is quite useful for extrapolation of point lithologic samples both vertically and horizontally.Unit E/F is recognizable in this ....profile and ref inements in the boundaries are suggested from its ..... examination. The gamma-ray profiles for the r~ver channel demonstrate a similar practicality ~n the much more complex geologic situation of rapid vertical and horizontal facies changes.The gannna ray anomalies recorded agree reasonably well with the point samples taken from the boreholes.Each of the river gamma/lithologic profiles permit better - - resolution of the river sections than the samples alone. A-9 ...---------------------------------------------~---------------- REFERENCES 1.Dobrin,M.B.,1976,Introduction to geophysical prospecting,3rd ed.,New York,McGraw-Hill Book Co.,Inc.,pp.292-338. 2.Cummings,D.,1979, interface in shallow 44,pp.1987-1998. Determination of seismic refraction depths to an irregular surveys,Geophys ic s,v. 3.Ragedoorn,J.G.,1959,The seismic refraction lines, 285-294. plus-minus Geophysical method for interpreting Prospecting,v.6,p.-i 4.Scott,J.R.,B.L.Tibbett,and R.G.Burdick,1972,Computer analysis of seismic refraction data,U.S.Bureau of Mines,Report of Investigation 7595,p.95. A-10 r r-! \ r- 1 I 4.TABLES WATANA DEVELOPMENT SEISMIC REFRACTION SURVEY RIVER CHANNNEL TABLE A-I Tn-1E-DIsrANCE DATA FOR S83-1 -SHOT POINT ELEVATION CIT)X LOCATION (FI')Y LOCATION (FT) 1 1454 0 10 2-1453 225 10 3 1454 450 0 GEOPIDNE X LOCATION (PI')ARRIVAL TIMES (MSEC) SP 1 SP 2 SP 3 1 10 1.0 16.0 32.0- 2 25 2.0 15.2 31.0 -3 50 4.0 14.0 29.4 4 100 8.0 10.8 27.0 .- 5 150 12.0 6.5 24.0 6 200 15.5 2.5 21.0 ~ 7 250 18.5 2.5 18.0 ,~8 300 22.0 6.2 13.0 9 350 25.0 10.5 8.5 10 400 29.5 15.0 4.0 11 425 31.5 17.7 2.0 12 440 32.5 18.5 1.0 ,- ,~ - .... I .... NOI'E: TABLE A-2 TIME-DISTANCE DATA FOR 883-2 883-2 was an attempt to obtain a seismic section perpendicular to the river channel.River surface geometry precluded placing shotpoints at sufficient stepouts to provide first ~~ivals from bedrock;therefore,only ice arrivals were recorded. -- TABLE A-3 TIME-DIsrANCE DATA FOR S83-3 TABLE A-4 TIME-DIsrANCE DATA FOR 583-4 SHOr POINT ELEVATION (PI')X LCCATION (PI')Y LCCATION (PI') ,~12 1456 1110 0 13 1455 540 30 14 1453 0 0 ..-GEOP!DNE X LOCATION (PI')ARRIVAL TIMES (MSEC) 5P 12 SF 13 SF 14 1 20 83.0 47.8 3.0 2 50 82.0 44.4 6.0 3 100 81.0 41.2 10.5-4 150 76.0 35.0 15.0 5 200 72.0 30.7 19.0 6 250 67.5 25.8 23.8....7 300 65.0 21.2 28.0 8 350 62.0 17.0 35.0 9 400 55.0 12.5 39.5 10 450 52.0 8.2 43.0.!fi'i'Mil 11 500 48.0 4.5 47.2 12 550 45.0 52.3 13 550 43.8 1.5 50.0.-14 600 41.8 5.0 52.0 15 650 37.0 8.5 55.0 16 700 34.0 12.5 59.0 .....17 750 31.0 16.0 62.0 18 800 27.5 20.5 70.0 19 850 23.5 25.5 69.0 20 900 19.0 30.5 70.0-21 950 15.0 32.0 73.0 22 1000 10.0 36.3 77.5 23 1050 5.5 24 1100 1.5 44.7 83.0 - - TABLE A-5 TIME-DIsrANCE DATA FOR 883-5 - TABLE A-6 TIME-DIsrANCE DATA FOR S83-6 ,- SHOT romr ELEVATION (PI')X LCCATION (Fl')Y LOCATION (PI') 21 1461 450 0 22 1464 1050 0 23 1459 25 0 23A 1459 0 0 24 1464 1585 0 25 1461 600 0 26 1462 1125 190 ,.... GEOPIDNE X LOCATION (PI')ARRIVAL TIMES (MSEC) SP 21 SP 22 SP 23 SP 23A SP 24 SP 25 SP 26 !"""' 1 25 3.0 51.5 84.5 2 75 6.5 48.0 83.0 3 125 11.0 43.5 79.0 4 175 15.5 39.0 77.0 5 225 20.0 34.0 75.0 6 275 25.0 29.5 73.0 7 325 30.0 25.0 70.0 8 375 34.0 20.0 66.0 9 425 39.0 15.5 63.0-10 475 2.2 46.0 43.0 44.0 93.0 11.5 61.0 11 525 6.5 40.5 47.5 48.0 91.0 7.0 58.5 12 575 11.0 36.5 51.5 52.5 90.5 3.5 57.3 ~13 625 15.2 33.0 54.5 89.0 14 675 20.5 29.5 59.0 90.0 15 725 24.0 25.0 62.0 85.0 16 775 27.0 21.0 67.5 78.0 17 825 32.0 17.0 72.0 75.0 18 875 36.0 12.0 78.5 58.0 19 925 39.0 9.0 75.5 52.0 20 975 42.0 5.8 76.5 49.0 21 1025 46.7 2.3 79.5 46.0 22 1025 47.0 23 1075 52.0 24 1125 60.5 25 1175 64.5 26 1225 66.0 ~27 1275 70.5 28 1325 76.0 29 1375 80.5 jiIlI!lI!lilll,30 1425 85.0 31 1475 87.5 32 1525 91.5 33 1575 95.0 TABLE A-7 TIME-DISTANCE DATA :FOR 883-7 r-SHYI'POINT ELEVATION (PI')X I.JX:ATION (FI')Y LOCATION (PI') 27 1465 825 0-28 1469 1425 8 29 1463 300 0 30 1470 17QO 0 31 1464 875 15 32 1463 285 0 33 1463 0 0 GEOP!DNE X LOCATION (FT)ARRIVAL TIMES (MSEC) SP 27 SP 28 SP 29 SP 30 SP 31 SP 32 SP 33 1 300 85.0 48.5 3.0 27.0 2 350 80.0 42.5 7.0 31.0 3 400 76.0 39.5 11.5 35.0 4 450 72.5 35.8 16.0 38.5 5 500 69.5 33.0 20.0 43.0 6 550 67.0 29.0 24.5 47.5 7 600 66.0 26.5 28.0 51.0 8 650 65.0 21.4 32.0 57.0 9 700 60.0 17.0 36.0 61.0 10 .750 56.0 12.0 41.5 63.5 11 800 55.0 7.8 43.5 67.0 r-12 850 53.5 3.5 46.0 72.5 13 850 2.8 53.0 47.0 76.0 14 900 9.0 50.0 52.0 75.0 15 950 13.5 45.0 55.0 70.0 16 1000 17.5 40.5 60.5 67.0 17 1050 22.5 36.5 64.0 66.0 18 1100 25.5 31.0 67.0 61.5 r-19 1150 30.0 27.5 73.0 59.0 20 1200 42.0 21.5 74.0 51.0 21 1250 44.0 16.0 75.0 46.0 22 1300 47.0 11.5 78.0 39.5-23 1350 50.5 7.0 81.5 36.0 24 1400 53.5 3.0 84.5 30.0 .- TABLE A-8 TIME-DIBrANCE DATA FOR 883-8 - TABLE A-9 TIME-DISI'ANCE DATA FOR S83-9 SHOT POINT ELEVATION (FT)X LCCATION (FT)Y LCCATION (FT) 39 1467 1705 0 40 1461 0 0 GIDPIDNE X LCCATION (FT)ARRIVAL TIMES (HSEC) SP 39 SP 40 1 550 98.0 45.0 2 600 95.0 49.0 ..-3 650 56.0 4 700 90.5 58.0 .- 5 750 87.5 62.0 6 800 83.0 65.0 7 850 77.0 71.0 8 900 72.0 76.0 9 950 68.0 89.0 ,- L 10 1000 65.5 89.0 11 1050 61.5 92.0.- 12 1100 57.0 96.0 - TABLE A-IO TIME-DIsrANCE DATA FOR S83-10 SHOI'POINT 41 42 43 ELEVATION (Fr) 1453 1453 1454 X u:x:::ATION (Fr) o 600 1150 Y u:x:::ATION (FI') 20 GEOPIDNE X r..cx:::ATION (Fr)ARRIVAL TIMES (MSEC) SP 41 SP 42 SP 43 1 25 2.2 49.0 82.5 2 75 6.8 47.0 79.5-3 125 11.0 43.0 78.0 4 175 15.0 38.0 77.5 5 225 20.0 34.0 76.0-6 275 24.0 29.0 74.5 7 325 28.5 24.0 71.0 8 375 33.5 20.0 68.0 9 425 38.0 15.5 65.0-10 475 42.5 11.0 60.0 11 525 46.5 8.0 56.0 12 575 50.0 2.5 52.0 13 575 48.0 14 625 51.5 15 675 53.8 16 725 56.0r-17 775 59.5 18 825 62.5 19 875 66.0 20 925 69.5 21 975 72.5 22 1025 76.5 1"""1 23 1075 80.0 24 1125 83.5 .- - .- ~ i j r I ~ I r 5.FIGURES WATANA DEVELOPMENT GEOPHYSICAL EXPLORATIONS .-1 o~ooi2~OO R83-6 6 too8+00 I IOHlO I...,.$.,.: 0+00 I 2+00 I 4+00 I6too12:00 ~-j ~iiJ ICE !'Ill" '450 '.A"9i'"i}'ji"WA7n1 A~i!i;;JI4<,.J\SJ;up 1450 R83-4 :t"~F ~)u;=-146Q~..__'__•_~ -I'~14!)O ! I >i 1141'0 W1E1W..~ICE ANU .-..T£/I1 __________ orooltoo .!!!;;L :\+00 :t+OOI! ~;j!4 4HlO I8100 ~ "'r ,.,.".,~,.,..,,,"'",...,1460 I J ,I I ~""I'/======-ICE,...-.'-~:t~-•i=\, 1450 ~...,~- ""'.',CE wm:."..SOIl.1450 ."-"',1·" >'-~~I'C£''''3"'1450~.1450 ~MIl SOIL 2pO 2+00 Ito" S;!1183-14 1183-10 ~"'l-~.-~.'...:::'4W SOIL '..,~ R83-8 ,4S7 .ICE ~14!56 l:;145l .,.:.".:•.-.'" irl $OJL -.-,.:.~....~>-;'+~.'~..v;~;. ~,.~ ~ 2:_I ZtOO I Itoo I ~OO >'-~=1-~14!lO :.•/./~IIIom"'"."50 .~~.SI'IL R83-1 3f'O 2~OO Of00J.~...3«10.., I it ZtOO °tOO NOTES' L ~~":i~NO.A I FOR PROFILE 2.\/EftTICAL SCAU:,"·10"HOltllONl'Al..!!CALf:.··100' FOft lONG'lnJDfNAL SECTIONS a '"·50'FO!' 'Il'IANSVf:RSE SECTIONS 3.PROfIlES lIA!IED ON INTEJII'flETATtOHS Of GEOI'tl'1SICAI.. l».TA AND AkE SUDJECT TO FIJTlJAE varIFICAT/ON. 4.AU.ELEVATlONS a STA"fIOlilNG SIiOW!II IN l'tt'T, ~r- >I~::=------------...IC£ICE ::1466 fC£----=__---.__-::;/:::~F.-~..",~.'C,,;a:.,SOIL,"1460 1450 1450 1450 .'450 Rft3-3 0:00 1nl3-11 3+00 I ~ ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT -RIVER CHANNEL ~ GROUND PENETRATING RADAR PROFILES GAtt I FIOURE~~IAUG.83 A-2 SP3 400300 40 ..,.....,e 30 .....~3:m 20 -3:.-.(I)./m >:/n 10 /-~........... 0 SP2 200 DISTANCE (FT) 100 4O-----------------r S71E- 30 w 2 l-10 ,U UJen !.20 -1~L-..L __l..........L.___,_14751475 -.FLOW ICE SURFACE 1450 mi=1450' r-HD83-34 (OFFSET 25 FT TO NEI mu. <...l>Z 7J)OO fps ....0 ALLUVIUM 0;:: BEDROCK Zct>15,350 ". ."W ....~ 1425 -w 1425 -~~--------------------U/-s ....14001400DIS EXPLANA TlON - •BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE •SHOTPOINT LOCATION ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-1 FIGURE A-3 EXPLANA TION 6 SHOTPOINT LOCATION r'"OEPTH RANGE INDICATED BY CROSSING seISMIC LINE ....BOREHOLE DEPTH CONTROL 60 ~50 I-40 -I 1-30 i m ~ t-20 ~ g r 10 ...... ~........r;-0 $P11 900 I -1475 I 800 : I I I I I .;, .Jti ; :!It •I ,---------.-.---.-----.----T ~ SPS SP8 SP7 200 300 400 500 600 700 DISTANCE (FT) •~•-----........---./~.~.~--------.--.............................--.--.........~_.~.>.----------~.---,..............--.: --_.------><.---~...................-----~.--.--.--•./".'"""--.~---.><:~~.~-~.--~~--....................--------~~~---'-;.............e_e ~,~ \. 80 IS70E- 50- 40- U I.LI 30-en~ U.I 20-a i= 10 .........---.--...- ..........--o r-I SP10 0 100 ----FLOW ICE SURFACE i=1450- ~ zo t= c( >w... w 1425- NOTE:14,500 fps refractor mdlcated at depths of less than 10 feet tor en rife line.PosslblV frozen alluvium,and /or attfred dioriH. HD83-36 (ON LINE)... 1-1450 mr-m<l> -Io Z :n -t 1-1425 - ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 1400 I DIS titS I 1400 TIME-DISTANCE PLOT AND SEISMIC SECTION FOR S83-3 IIMlA-EWCO I D"TE !FIGURE SV$lr"..JOINT JlENTUH£lAUG.83 A- 4 EXPLANA TION TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-4 •SHOTPOINT LOCATION ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT •BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE 1350 1325 1450 1425 rnr-m 1400~ -to 1375 z -:.n -4 :90 80 70 60 -tlsoi m ~40 enm,g 30 ;20 10 1000900 <!I' ; ~ 800 ICE SURFACE 700 ALLUVIUM BEDROCK $P13 500 600 DISTANCE (fT) 400300 HD83-30 (OFFSET 15 FT TO NE)... .......-FLOW 200 15,OOOfps 100 S73E --.....e_.~_---.""....~•~ .~./.--.--~e ____ e _____ ."",.-----.,e_________~ •e~~:• ".~~.--.~.---.~~.~../.----.....J .......... ~/"r.""-.~.----.....---"":<.>:/ ./.~/.~~ //.~..~.."" ./'.~.~-.............~.-"-.-----.#............ ...........e ......................~.,.~,. I """""•'1475 90 i • 80 70 60 0w 50(I) !. w :E 40t= 30 20 10 0 SP14 0 1475 .... 1450 1425 t= ~ z 1400 0 i= c(~1375 ..Jw 1350 1325 1300 IDIS IMIU·BUC~ SUSl7iOJA JOINT VEN7VRE .8 ~A~5 1475 1450 1425 fitr- '"1400 ~... 0 1375 z ;; .:! 1350 1325 UlS I 1300 100 90 r: ... 50 i '"~ 1-40 Cit '"!2 30 20 ~'_l': SP1' 1600 T 1500 I 1400 I 1300 T 1200 ) !iff ICE SURFACE A T I ---.-----~I T----'- SP16 SP15 600 700 800 900 1000 1100 DISTANCE (FT) T 500 T 400 T 300 /'"-/e ;.~.-----..---""-------.--....'-.................... ~'-"""""".,--"-~-.--.><.--.------.-'--- ................"""~-,~~'-~~~~-..~~~~~"-.../"" .----•1 ".-""'X _.................~/.~~............."~,.....//.~ .....",'-/"~.~'".\ .-~~-~ ,/ /e 100 IN7SE-----<- 90 80 70 60- U~50- ~ uJ :E 40- j:::: 30 ~ 20 10.,--,/----or I I SP17 0 100 200 1475 1450 1425 E ;;1400 0t=~1375 w ""~w 1350 1325 IDIS 1300 EXPLANA TION -+-BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE ALASKA POWER AUTHORITY •SHOTPO'NT LOCATION SUSITNA HYDROELECTRIC PROJECT TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-5 ~,~.~~;!~1~~~~IAUG.8]A- 6 100 90 110' 70 60 ..... irn 50 ~enm 40 !! 30 1-20 10,-I 0-SP15 1700 1415 ~1450 m,.. m<~ ~1425 ~ 0Z ;; ~ 1-1400 1'375 u/s TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-5 (WEST) ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT f 1600 t 1500 f 1400 f 1300 I 1200 ) ff ICESURFI&CE rItI .; f.I /.Jj---ALLUVIU.,j ~!I,f 1,OOOr,.-- 18.000fPf EXPLANA TION ...BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE •SHOTPOINT LOCATION I FLOW III -"""'--.--... .~.~.~..--.,,---------.><: /~.--..--'----.----.~-,---.~'......~~.'............ ",...........",...---.................-----................... ",...---.--......,,---------./~.................-.-.~.........,,"'">:./'-......,......................"."'"-...............' ",../",...~."J "........ ",.././.,,-......,,.,/./".~............ ...../~...........''''-""..,,//."-................... o I If'"I iii I a/I ,I I I :'.I I I I I -" SP20 SP1.SP16 o 100 200 300 400 500 600 700 800 900 1000 1100 DISTANCE (FT) 30 .... 10 Nl2E- 20 70- 10-'.- ,.i t III ~ ;:40- --U...•&50- 1475 •I 1450 i= !: ~1US ~>... '<!\-'III 1400- 1375 ... I 011 1IAIU-(MflCI -r-OATE _I FIGURE SVStTf;,s ;011.1 VEtiTURE IAUG.8~A-7 80 I-60 -f ~ I-10 50 'f enmo I-40 - I-20 1-30 ---.----._-.--.----'"; __..['00--.'- --'-~.___.......L-..·.·90 "'-----""~.------..----"~«--<"<.<<<"<<••<<<<< ..-------/"/./.--.---~.-/./"'-..~~./y------- "-.•~I...-""'------~./~ '-.......~/~-----------/"'-..~/«~'-"------.J,.,/-~~..-.------~-'-~:.-----X:-<~·"~-""~'-.....--..~'----~.,-::7 '"a.<--'-"./~_/•/---.~'!'--~..;:;-~"'-....,.-----'~'--I/·_~~~-----<~.------."-----~.~--------'./......~,,~~'-.~-------.'--~----,'k I'l 'I-10 IO.•I I I I., -"ji sP23A $P23 SPZ1 SP2S SP22 SP26 SP24 o 100 200 300 400 500 600 700 800 900 1000 1100"1 1200 1300 1400 1500 DISTANCE (FT)..... 20 10 90- 80 70 -60uwen~50 1&1 ~ t=40 30- 1475 1450 1425 ~1400 z 0i=1375 c( >&U ~1350 1325 1300 1275 1- 0"83-3 IOFFS£T 20 FllO NWt -+'----.,... "'-, ~:"<'", 8('"0 ~(';+ "Dc>.... 6,750'" HDII3-37 ION LINE•• 11.500'" •HD83-3I ION LJHE' ~ 1475 1450 1425" 1400 ~ <> 1375 ~ 0 Z 1350 ~ 1325 1300 u~I 1275 EXPLANA TION ...BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE •SHOTPOINT LOCATION ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT TIME-OISTANCE PLOT AND SEISMIC SECTION FOR 883-6 A-a 10 80 70 60 ~SOi 1ft 40~rng 30 20 10 0 SP30 1700 1450 mr 1ft< 1425 g z ;; =! 1400 U$I 1375 16001500 SP28 14001300120011001000 883-8I 7.(JOOfJn 76.5OOf". SP21 SP31 800 900 DISTANCE (FT) 700 •OH83·'(OffSET 3S FT TOSEI 600500400 SP32 SP29 300 ~ BEDROCK 583-17 (OFFSET 20'TO NWI• e~e -"-----...-...--e____._.".--.----~'".-.-.-----/../'._-._-.~.---../>---.~'",..--- ./.----../., •e/~.---,".•____,~~,~~~.---.~..-:;::-~~..---"'".><:----~----./.---.~.~.~--~.............--.----..,....,.;:--. .....-~--~--...... .....-",/~./~a """............. ",'"~........-......................./................. /..__-.~................J ~.........................:._--/.~.~....................--................/.-............'.......~-~.--.....................~.................. 200 I !I !!!!!!,,I ~..',,,,f 1475 90 I N28E ----<- 80 70 60 U &.U 50C11~ &.U~40 i= 30 20 10 0 SP33 0 100 1475 1450 i=" ~ z 0i=1425«>iii ..J iii 1400 I D~ 1375 EXPLANA TION ..BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE A SHOTPOINT LOCATION ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-7 ~;!~~~@ ~UG83 A-9 EXPLANA TION •SHOTPOINT LOCATION ..BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SeISMIC LINE ~30 "-60 '-20 1'-80 1--70 ;f-40 ~ :1 !2 e--. 70- 90 i :i.~9 N56E -----.--------------~.~~._-.~. ~.~..",--.----."".~.----...'--------..~~.---e____.~___:<_~--.'~50 ~ .___....:::---./_.m /'---,/'------'-'-'-"'"/-.----".~...-------.../---'-'-'--"-~/-~,~. /'-e,,-~e ":~~~e '-....-"-/.,-/',~ e -.........../'e "e~.~~..~...................,. /.~/_.,~.it-10 e .~~.:.........,"'-~~/-,',-"1oI~I I I I a..I I I I I •0 SP34 SP37 SP35 SP36 SP38 o 100 200 300 400 500 600 700 800 900 1000 1100 30- 40- 10- 50- 20- 60- 0-wen ~ w ~ i= TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-8 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT r 1450 '-1325 "-1350 [ 1425 1400 ~ -toz.....1375 _ -n =! U/S ---------BEDROCK ALLUVIUM 6,000 fps 16,500 fps 1583-8 I I ,I I I I I I I _FLOW ICE SURFACE I !'.1475 I :'1300 1475 ~ 1450 - 1425- t= Ll- Z 1400- 0 i= ~1375- w ..Jw 1350 - 1325-I DIS 1300 lIDU-fWC@ I DATE J FIGURE SV$IT,.,"JOINT VENTURE 1~L!§.~A-to 100 l--90 f-80 I-70 f-GO ~ ~ I-50 'i enm 0 f-40 - .....30 .....20 t-10................... ~O SP39 1700 1475 145() 1425 1400 ~ m<l> 1375 g Z 1350 ; 1325 1300 1215 I 1600 III H083-39 ION LINE' I ... 1000 I lJJ(J()f,. ICE SURFACE 800 900 DISTANCE (FT) 15,500fpa ~BEDROCK I 700 I 600 IIIII N!i8E_ 70 80 60 40 30 20- 50- 10 - 90- ~. ..~.-------------,-/100 I ":>< /"---""-- -----'a"~-"~"~........-'.... / -".... ....., "-'....~'",....., /'.... ;'.... /;;/'....,-;///.,-_.....-----.,"......,., O~- uw i III :f i= SNO 0 100 200 300 400 500 14751 I I , ---FLOW 1450 1425 j:1400~ Z 0 1375i=~ .~1350w 1325 1300 I DIS 1275 EXPLANA TION •SHOTPOINT LOCATION -+BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT TIME-DISTANCE PLOT AND SEISMIC SECTION FOR 583-9 ~;~:!~!£~~UG.A-II 90 T'~~~==----------------------------------------------------l....:.S62E _,i 90 EXPLANA TION ..SHOTPOINT LOCATION ....BOREHOLE DEPTH CONTROL I DEPTH RANGE INDICATED BY CROSSING SEISMIC LINE ~'70 ~ ~40 ~ 9 ~··30 '-20 -1 I-50 ~m I-10 1-60 70 .... 80- 20- 10 .... 30- 60- w~40- ~ .~.---..=.....__/-"'rbi80 e __.••.............- e,----'e~e ____-----.~. '----.~e~..~~.~-.~.~. u ~........---~50 ~:..:><.. .!.~~.......... .~........... -........../........~/.'................ .~.'............/................><'.......~..~.......,......... /..~.........,./.................~~.----)............./............."'.........".........~................. oiL I I I I I '.I I I I I >!a SP41 SP42 SP43 0100 200 300 400 500 ,600 100 800 900 1000 1100 DISTANCE (fT) I _-1475 .....1450 ~1425 1-1400 ~ m<» 1-1375 :j 0 2 f-1350 ~ ALASKA POWER AUTHORITY_I SUSITNA HYDROELECTRIC PROJECT -1325 I TIME-DISTANCE PLOT U/S I I AND SEISMIC SECTION 1300 FOR 583-10 om·ffM'C~I DATe~FIGU~E SUslTNA JOINT VENTURE AUG.,'A-12 ... HD83-29 (OF FSET 25 FT TO NE) ICE SURFAC~ __--__H.....083-27 (OFFSET 20 FT TO SW) ... HD83-48 (OFFSET 15 FT TO NEt 6.750 fos 17,000 Ips ~ BEDROCK _FLOW Dis1300.....i1_~~~~'J....1 1475 I I I I I I I I I';;I I I i 1325~ 1450- 1425- t='~1400- Zo ~1375-«>w U;1350 ... GAMMA LOGS -RIVER AND RELICT CHANNELS - .Counts Per Second (cps) 0 10 20 30 40 50 '.<2:t::><t::::::> I c::~10 c ~<:rs20~;- t><:5:<~- 30 <:- ~-Q)40 Q)---t:>u.<:::. c: <2 ~- .r:I--~Co Q)500 ~r--- , 60 70 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-4 _. IMIZA-Ewa ~IDATE d FIGURE SUS/TNA JOINT VENTURE UG~8 A-I '3 I Counts Per Second (cps) ~ 0 10 20 30 40 50 I-"----R:....<:10 "- ......<~ ~ 20 c.::=::: 30 ~~- ~~-Q)40 cD c::::::::.~-u. c:::- .s=-~c..-- CD 50 ~ C ~.... ro-.~ I ~~80 r-. ~po .... ~ 70 ~ ~ lef I 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT.... 90 GAMMA LOG HOa3-5-- HAm-EWe,t DATE d FIGURE SUS/TNA JOINT VENTURE~UG.8 A-l4 """' Counts Per Second (cps)" 0 10 20 30 40 50 <:l5 ~10 ~ 20 -?.....~ 30 5 -CD 40 CDu. c:- ~-Q CD 50C f60 70 'It80I~ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT GAMMA LOG90-, ~HD83"-6 IIAIZA-EUX'~tATe d FIGURE SUS'TN~JOINT VENTURE UG8 ~A-r5 -. -I .... - Counts Per Second (cps) 0 10 20 30 40 50 ~-~~10 S 20 <~ ~.r30~b ""<>I:>-Q 40 <D ..s;;;::>u. c 'i~- ..t:~-C. <D 50C ~~ ~ <::::::' 80 ~ I~ ~P 70 ~ ~ ~ ~- 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG H083-B .lfAIZA-fMlC'Ii DATE S~FIGURE SUS/TN..JDINr VENTURE AUG 8 A-16 >f- I-u l"-ei:~i!'- 0 0 5 Ia:~<l::r:0..C'!5 u O&~a:0e(f-..J enuIa::UJ «(Y)w ...J ~UJ ::E CO00 ~g0a:::Ec J:c..>-«e(:t:C' Ol:~~«I(J)Z f-e(ii3...J :Je((f)i ou o 08 t-"ll,l1! OL ~aa.::l UI 4~daa 09 O~0&0 .. f------+----+--~-""=:---t----_+------t0i. f------+----t---~q------t----__t 09 I-----+----I--E==---+------t----__t O~ f-----t-----+----=?p:a-----t-----;0 .. 1-----t-----+-----:::::lP""-----+-----j 06 1-----+----t-----'friE::::-----t----__t OE: I-----t-----+----t----:::::""""i:""-t-----;00 i. 09 (sdO)puooas Jad s~uno::> Counts Per Second (cps) 0 10 20 30 40 50 .~ ~r---.10 :::::>---p 2 ~c= 20 ~e>. ~<:~<:~30 ~v--~ ~I>.. CD 40 CD '1 ~ LL ::?c:<-~ .J::,~.. "'-a. eD 50C ----~'Ii •~80 ~ J-~ 70 t------+------+-----+------+-------I 801------+-----+----+------+--------1 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90------L------L----....a....-.-----.GAMMA LOG HD83-:20 um-_n L OATE_J FIGURE SUS/TNA JO/NT VENTURE .IAUG.831 A-18 Counts Per Second (cps) 10 20 30 40 50 80 70 80 90 100 II E I,c::::::::>+---~<:I~II - I ~c:::: .-'C::::=- I ce~ -, ~~) )~-..--"'~ ~t T-c ~.;. L .. '""!II I ~---+ I ~ ~r\ o 10 30 20 40 50 eo 70 Depth In Feet ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT GAMMA LOG HD83-21 um·EW~C lAUG.8315U51TNAJOIAITVUlTURE FtGURE A-19 - - - Counts Per Second (cps) (}10 20 30 40 50-----z-..-p::.~10 <::J---c:::::::..J 20 v=- I «~ 30 --.... .~-CD 40 cD ~~ c- .c-c:: Q,c:::> CD 50 '- 0 i.~ <:~60 ~!> ~~ r>10 <:::::....---.... ~ 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG "HD83-23 JIAIZA-'"~l DATE l~FIGURE SUS/TNA ..JOIWT VENTURE UG.8 A-20 >-I-gNis: 0 !!!I J:C!J ~« I-:J 0 C\I<:...J C\I0::«IUJ(¥)tI);::2:IX)wlX\ 0 :::;;:0 ~g D.«::I: <:C!J ~~ (f)i<: -I<:j OE 01. O~ Ot Ool OH 08 06 001. 09 09 0 I . '----:;;b.. .... ...;::t--:. .~ ~P <:,.-, -e:k r;:-s-<:::r-> c ~<,I -....""~,'-oIi.,r ,,"'~ ~, ~~ ~ 5 i: ? K ""'F----r----~17 "\r---- Ool 09 09 Ot OE O~OJ. (sdo)PU009S J9d SlunoO o .... .... ....., Counts Per Second (cps) O·10 20 30 40 50 <:::.-r---.... ~. <:::....... :?~ 10 <Vcp 20 '--. ~r--.. .~.-.. I-=:;;;;;;;" 30 --"", ~-~' 4)40 (I) u. c:- .c:-a CD 50C 60 70 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-24 lfAIU·muCO ~IDATE 3~FIGURE SUSlTN,J,.JOINT VENTURE UG.8 A-22 r - ~.. """ - Counts Per Second (cps) 0 10 20 30 40 50 10 I~r---- r~ < p (R20 <:::::... <~ rz..c::::: 30 ~ -~. Q)40 Q)-=- LL ~ c:..,;:;;:::> -c:::::::~~-a. Q)500 :? ~~ 60 <-~,..~ ..",. ~ .c::::::r---- 70 -c:~ :2: 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT .. 90 GAMMA LOG HD83-26 lfAIZA-fMftaJ ~t~~~FIGURE ..SUSITNA JOINT VENTURE UG .A-23 - ..... ..... -- Counts Per Second (cps) 0 10 20 30 40 50 60 70 ~ ~> 10 ~ 20 <:... r----I-- -= 30 I-CD 40 CDu. c: .r::.-C. (1)50C ~P- 60 ,/ 70 5 IZ80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-27 IfAIZI-E&UCO ~tTE ~I FIGURE SUSI7WA JOINT VENTURE UG.83,A-24 - ..... ..... ..... ! - Counts Per Second (cps) O .10 20 30 40 50 . 10 .<e:p b 20 c;::~ 30 -Q)40 Q)l5u. c:- .c:<-0. Q)50 C 60 ~~70 --..~<:D=-.c::~~80 ~-.~ALASKA POWER AUTHORITY"---SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-28 um-EWtC'~t~~FlQUFlE SU$IT7VAI JO}NT VENTURE UG.A-25 - ~I I ..... -Counts Per Second (cps) 0 10 20 30 40 50 60 70 > 0-- 10 ~ ~-~ ~ 20 -> <::l?-=--::> ~t:::>~30 ~ c:::::: ~-~CD 40 cD ~ LL ~C- ~-c. cD 50C ~c:: 3- ~--60 "7' c ~---i'" 70 ....:::::. ~ 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-29 1IMU·ra.=.~IDATE d FIGURE SUS/TNA JOINT VENTVM ,UGw 8·..-A-26 -- - ..... Counts Per Second (cps) 0'10 20 30 40 50 10 ~ <~ ~20 ~><::::; ~..P30 -CD 40 CD ~U.~s:: .s::~Ei-.-Q :e(])50C s.. J ~60 ~~ c:::::::::. ~ 70 80 - ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD8S-S0 .IfAm·EMlC.blo ATE sl FIQURE SlIS'ITNA JOINT VENTURE UG.83 A -27 .... - .- .... Counts Per Second (cps) '0 >10 20 30 40 50 ---- ~. 10 3 20 ~~ .--Jc:::::. 30 I~ ~ 2"--, P-<:>40 -CD ~LL.?c- oJ:-a r--- <II 50 ~ 0 •--:=:0 ~--r-......- 60 ~ -I==- 70 ~ c:::::;~ l?.c: l>80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-31 HAm·muc,~tATE d F'GURe SUS/TNA JOINr VENTURE UGB A-28 - .- , .... Counts Per Second (cps) Q 10 20 30 40 50 2 10 ;;. r-==- ~c t:=:> 20 I 30 -C)40 CDu. c:- .s:::-a... (1)500 60 70 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-34 HAm·EW~'~t~~td FIGURE SUS/TN..JO'NT VENTUll£UG.A-29 -i -- ..... .- Counts Per Second (cps) I 0 10 20 30 40 50 '--Z t:;:> <;;~10 20 "'$ -: ?I 30 ~<::f2-Q)40 Q)<~~ c:~..c-c.~Q)50 C "---- 60 70 . 80 ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG HD83-35 IIAIU·EW«:'bt'~~.FIGURE SU$ITNA .JOtNT IIE}'inJRf 00.A-30 o Counts Per Second (cps) 10 20 30 40 50 ....., - - 10 Qi 20 CD LL .5 .r:.-a. CD C 30 40 50 --?~ I~ <:~ ~ ":----.......... ;::::l ~po ? <:t:::::.. .~ p0- l> ~l' ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT GAMMA LOG HD83-36 1fAIZA·£WC4P SUS/TNA JOINT VENroflf FJGURE A-31 >-to- ~0 C\lwa:(5 li!f") 0 g I 0::'«J:Q."~0 O&~i'!0 ,....I e:(to-...J C")ua::w I I w ..J «C')YI~w :!:co ~~000:::!:c ~::;la.Q J:>-« e:(I "~~0, O~~CfJ z i~to-e:((jj...J ::l i~e:((/l O~~ f------+----+----<s.t------T----~00 ~ I------t-----+-----+---Y'--+---___j 06 1------+----+-----+-----"~---___108 I------+----+-----+------te::==---~OL I------t-----+-----+-----+-;;;-~-___j 09 I------+----+-----+----~r_---___i09 I------+-----+----+--=,..-:::=::t='----___j Ot I------+----t-----+-----~=__--___i0& 1-------t-----4-----+------=--k::------i O~ 1------+-----4-----+--:==-""'--f-------1 0 ~ 09 Ot 0&Ol'Ot o (sdo)PU009S J9d s~uno~ I lC::::::::::-=------1.I----t-..,....,---..,..-.-----JL-----+I-+-----+------t-~=--====-.....L··~1 -~ - ---- ----I-------------j---~--- t------+-----.----j----.-..... L-----4-------+---·----------~---------I----- --1- de Os (SdO)puooes Jed sJunOO I I (8 ----------Jl-----+---+-----'----------..Ji---------+-------1- ------~--1--------+---_._._----~I_--·-----------_·_I---~-----I--- I 1--------j--.--7-----.-r-------t--------.-- : 01 ~ : c ~ J"cs. ~~ c ~ /---;-------I--::,. f1? ~., ~p c:::=:t=:>.~ "'"~ ~ :~~ t-;::. .~'.D ~r ..'t"1rI).:• d ..::=~ ~~K ~_.. I <~~ ~ I ~~~ -,c:::::::::-p ~--- ~' .., -==--(;==' I c:=::::£.F=--- I ~ I 'e::k:== ~p 1----,1-' ~b---~~ ~bo..::::::::-I-L--~ DEI. 0~1. OH 001. 06 09 Ot 09 09 Ot OE O~ O~ ~aa.::l ul ~~daa >-I-~~a: 0 a J J:C' ~<t !3 0 C\I<-l 'Va:«fw('I'):::E IX)I;'~0 :E 0 ~:::>Q.«J: <C'I:ll::en<..J<i OL 09 09 Ot'OE O~O~o o Counts Per Second (cps) 10 20 30 40 50 /p:-. -CD "....CD I U- .s .c:-a. CD C - - 60 L..-L....-...-..I.--'-......I-------l ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT GAMMA LOG HD83-43 sus/rNA JOINT VENTURE FIGURE A-35 ..... .- - Counts Per Second (cps) 0 10 20 30 40 50 10 ( 20 ~~ l--?L:::- 30 ::::» / c -Q).0 Q).c:::::::: LL '""" £:~- .c 17-a. Q)50 "'"C -<~ t"2" ::::.. c ~ 60 D ;;:. ~ I~ 70 80 ALASKA POWER AUTHORITY c SUSITNA HYDROELECTRIC PROJECT 90 GAMMA LOG .H083-44: lMIZA·mua I.DAi~FIGURE SUSJTNA JOINT IIENTURE AtJei A-36 Counts Per Second (cps) o 10 20 30 40 50 r---==r======t==:::r=-"I~ 10 ~--------"f------+~-r~--+------+------"'" ,..... -20CD,-CDu.. .s .J.:--0. CDQ,30 .- 40 ~----t..:::....._---+-----+-----1-------! 50 t-----!------t--..:="".._=--+-----1-------! ..... 60 ~'-----..I..-.J....-J..-.-----J ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT GAMMA LOG HD83-48 lMIZA·fIIAIC' SUSITNA.JOJNT VENruRE FIGURE A-37 o Counts Per Second (cps) 10 20 30 40 50 ~Q) <D U. .Ei-~-C.<Da- ,,",,,,,,, r-, -- .... 10 20 30 40 50 ---a ~ ~ ~ ....- ~ ~....- ~ ~I"'" t3:-~ .r- ~ ~ ----~ ~ -=:::::'.:~ ..J: ~ ---.. ALASKA POWER AUTHORITY o SUSITNA HYDROELECTRIC PROJECT GAMMA LOG HD83-41i MIZA-EWe. SUSITNA JOINT VENTURE FIGURe A-38 >I- ~0 wCJ'lwii:a grt) 0 II:~IIa."<!~0:::J ii 0 IX)«I-....J0 ~c:~<C IW(Y)3:w ~0 co ~ci0II:~00 0::>a.>-<C :I:«I "::£<{I(/J z«I- iii...J :::l«III i 01. OE 06 OB 01: Ol 01' os 01. 09 0 0 0 '<;,:::;.. ~0~~ .."""... ~ ~t>--I~ ~p ....r 1,-.,,:h ~.:---~L -=:::::: ~. I=- ? ~-~t:~ <I> 2.E! < ~ <"----; os OE:O~Ol o (sdo)puooes Jed s~unoo o. Counts Per Second (cps) 10 20 30 40 50 - ,.... 10t------.11---......:::;;;.--+-------l------+------..-, o;20t-----,1---__-=1-----+-....,.----I--------1 OJu. .c :5 &r o 30 ~---_+---~_t_----t_---_+----_1 4Ot------t------t-----t------t---------\ 5OL...----'---L ----l........1....-_ ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT GAMMA LOG HD83-49 FtGUAE A-40 >-~....l..lwa:..,~~ 0 0 g , tr "c::{F=0-C)l) oe~::J Ci 0 0«~..J It)(J0::w «IUJ..J (t)~w ~CO w<q00c:~0 ~g D-o J:>-« oc(J:C) ~«IocaC/)z oc(~ (ij-I ~oc(Ul j ou o 09 '''.Ii OL lea.::! ul 4~dea 09 OJ. ---+-----109 o~OE ---+---0:;;--+-----+--------1 O~ 01' .----t------I-----r.=,.,.....=--j-----j 00 l- f------+-----+----.:::::::::::-t------\-----t OE: l------1I------+-----.:::.~r__---_+----_i 0 l- 1------+-----1----..::::::......,..,=-----+-----106 I------!-----!------..:-===t:=:----+-----;0'" os (sdo)puooes Jed SlunoO SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITY GAMMA LOG H083-51 Counts Per Second (cps) 1""'""00 10 20 30 40 50 F-~.-.10 --d :> ><;::>.z:.20 F-L; ~><::~.-~l> 30 I>-FS. -JQ)40 CD ~LL ""- c <~-~.s::-Cl (I)50 ::::::.. 0 <~. ~ ~ eo f~ 70 ~----+---=?I---+------t-----t-------I 801------+----=-+------t-----+-------I~. t?r~ 90 L..--_-L--_~~.L.....----L------t lfAlZAofWCO I.,DATE .1 FIGURE SUS/TItA JOINT VENTURE ~UG.831 A-4·2 .._----'---- I S c::::::=~ <::::::::t::::> .~ ~ ~~ ::::::::.. '=-=- Z>£ <::I--"" ~P""",;.,r .,":I>D c:::::::::~ k?\ c:: c:~ ~~~ ~p:,-c:::::l> ~> <:- .:::::::::::::> ::> ~p ~po<~c ~.::::::~ V ~t? r--.- Ott O~t OH 001 06 08 Ol 09 09 01' oe O~ Ot ~aa:i ul l/~daa >-l- I-(.J If') 0:~ll!'lt 0 0 15 Ia:'<[:I:0-0I-(.J::>[t 0<I-.....I 'l:t(.Ja:w «cbw...J 3:w :i co wQ:l00a::i J:~t::I a..0 C ",;:) >-«<:I:0:lIl:::«i(J)z <I- Ui-l ::>i<CfJ 09 09 01'OE O~Ot (sdo)puooes Jed sluno~ o ~ i APPENDIX B -DRILLING AND SAMPLING METHODS 1.HAMIVIER DRILL RIG 1.1 Percussive Hammer 1.2 Rotary Drilling 1.3 Additional Equipment 2.ROTARY DRILL RIG 3.SAMPLING 4.DRILLING PERFORMANCE APPENDIX B DRILLING AND SAMPLING METHODS The January to April 1983 Winter Exploration Program included subsur- face drilling along the Susitna River Channel of the Watana Damsite and in the Watana Relict Channel.Early drilling in the relict channel area was discontinued when the rlver ice became thick enough to support drilling operations and was resumed after the completion of the river drilling program. A Becker AP-IOOO hammer rig drilled 5,239 feet of borehole,using a percussive hammer,occasionally switching to a rotary attachment when drilling conditions became difficult·lD deeper boreholes.A lightweight rotary coring drill rig was mobilized late in the program for the river areas where ~ce conditions prohibited the use of the heavier hammer drill rig.The long year 38 rotary drill rig accounted for 398 feet of the total 5,637 feet drilled during the winter program. 1 .HAMMER DRILL RIG 1.1 Percussive Hammer The hammer drill ng used a diesel pile hammer to drive a double-wall p~pe while a reverse air circulation system removed the cuttings as the pipe advanced.The inner pipe of the double-wall pipe directs the incoming air through the annulus between the inner and outer pipe to the bottom of the p~pe.The returning air with drill cuttings then passes up through the inner pipe into an energy dissipating cyclone that vents the air from the sample.Specially des igned tooth bits are B-1 used to penetrate the soil formations and to direct the soil into the inner pipe.The drive pipe is withdrawn by a puller system comprising two SO-ton hydraulic cylinders operat ing tapered slips that grip the pipe. The hammer drill rig used for the winter program was an AP 1000 (All Purpose)manufactured by Drill Systems,'Calgary,Alberta.The basic elements of this rig include a Link Belt 180 diesel pile drive hammer delivering 8,100 foot-pounds per blow operating at variable speeds to a maximum of 95 blows per minute;a SuI lair Rotary Screw Compressor rated at 750 cfm at 250 psi;am 18 gpm Beam mud pump;a hydraulic hoist,a hydraulic pipe puller;a mast;and a cyclone. The hammer energy 1S delivered to the drive pipe when the hammer strikes the drive spout which sits atop the drive pipe.The double- wall drive pipe 1S designed so that only the thicker outer pipe trans- mits the hammer energy to the bit.The two sizes of double-wall pipe used in this program were 5-1/2 inch O.D.X 3-l/4-inch I.D.,and 9-inch O.D.X 6-inch LD.The 9-inch pipe was used for approximately half of. the footage in the relict channel while the 5-l/2-inch was used for the remainder of the relict channel and most of the nver channel.A triple-wall drive pipe system using a 7-inch pipe over the 5-l/2-inch double-wall was unsuccessfully attempted at the beginning of the program. There were two basic bit designs used with the drive pipe,crowd-in or web tooth and crowd-out.The crowd-in bit has the cutting edge dia- meter slightly larger than the outer pipe diameter which forces all the material within the hole up the inner pipe.The crowd-out bit,with the cutting edge at the inner pipe,samples only the material directly below the 1nner pipe and pushes the remainder aside as the pipe advances.A 5-5/8-inch web-tooth crowd-in bit was used almost B-2 ~ I - - , - - .... .... ..... ,.,., exclusively for the project.Crowd-out bits were used occasionally when crowd-in bits were unavailable. 1.2 Rotary Drilling The AP 1000 had the capability of rotary drilling by replacing the drive spout with a rotary drive head.One drive head,the Center Stem Recovery (C.S.R.),using a high-torque,-slow-speed gearing,advanced the 5-l/2-inch double-wall drive pipe by rotation.The C.S.R.rotary normally used standard tricone or button tricone bits.The same reverse circulation system used in hammer drilling was used for the c.s .R.rotary. The rotation of the drill pipe helped to reduce wall skin friction. This allowed more drilling energy to be transferrred to the drill bit and helped to increase penetration.Also,the C.S .R.rotary with a tricone bit was used to penetrate boulders.Unfortunately,the recovered sample was usually comprised of rock fragments and did not give a representative grain size distribution.For this reason,the percent by weight of fractured material retained on the 3/4 inch sieve was always recorded during testing to serve as an indicator of the crushing effect.Also,every change between C.S.R.rotary and hammer drilling,or change of drill bits,required the removal of the entire drill string which contributed to borehole instability and redrilling of caved borehole sections. The 7-inch,triple-wall system using the C.S.R.rotary and an 8-inch tricone bit was attempted in the last hole l.n the relict channel. Excessive wall skin friction limited penetration and forced the aband- onment of the borehole. B-3 The other rotary drivehead,the Diamond Drill Rotary,had a high-speed, low-torque gearing for N-size conventional and wireline core drilling through the drive pipe after bedrock or refusal was encountered. 1.3 Additional Equipment IlI\ I - .... A down-hole hammer fitting through the'drive p~pe was also used to drill a pilot hole ahead of the drive p~pe when the drive pipe encount- ered refusal.The down-hole hannner easily penetrated boulders and bed-.... rock,but did not penetrate the softer unconsolidated materials because the resilience necessary to complete the hammer compression cycle was reduced. Occasionally,a 2-7/8 inch tricone bit was used with the diamond drill rotary to penetrate very dense refusal zones where the hammer drill or the down-hole hammer were ineffective. To drill angle holes,two 4S-degree angle blocks were placed beneath the mast.Four 4S-degrees angles holes were drilled by the hammer drill in the river channel. 2.ROTARY DRILL RIG A light-weight rotary core drill rig was mobilized later in the program for the river areas where ~ce conditions prohibited the use of the heavier hammer drill rig.A Longyear 38,sectionalized for helicopter transport,performed standard diamond drilling using NX-size wireline with NC-size casing. B-4 .... -, - - .... 3.SAMPLING The reverse circulation system used on the hammer drill rig provid.ed a composite sample of the materials penetrated.A geologist/soil engineer cont inuous ly monitored the drill cuttings dropped from the cyclone.A sample was usually collected every five feet by first clearing the inner pipe.Then the pipe was driven one to two feet before retrieving the sample.Somet imes,when sample recovery was reduced,the sample sect ion was extended beyond two feet.The sample was classified and placed in a canvas bag for transportation to the field laboratory.Samples for moisture determination were placed ~n plastic bags and sealed. Disturbed but intact samples were recovered us~ng a split-spoon drive sampler.A 2-l/2-inch diameter sampler was used with S-l/2-inch p~pe, while a 3-inch diameter sampler was used with 9-inch pipe.The first two S-5/S-inch bits used were reamed for the express purpose of passing the 3-inch sampler. Standard penetration resistance blow counts per six inches of penetration were recorded during the driving of the split-spoon sampler for estimating the relative densities of the materials sampled.The material directly beneath the drive pipe is considered highly disturbed due to the hammering action of the drive p~pe. Blow counts were also recorded during the drive of the double-wall pipe for estimating material relative densities.However,the energy 'delivered by the diesel hannner was not always constant because the driller adjusted the fuel injection control pipe penetration rate . Also,the resistance to penetration,due to wall skin friction, increases with depth thereby absorbing an increasing amount of hammer B-5 energy that could be delivered to the drive bit.Therefore,drive pipe blow counts will not be used to estimate finite density values. Grain s~ze distribut ions run on those samples recovered by the hammer drill rig are not fully representat ive of the ins itu material s.The hammering action of the drive pipe bit fractures the coarse gravel, cobbles,and boulders producing a gradation skewed toward the fine - -fraction.The hammer drill system also has a tendency to recover a larger portion of the fine particles,especially when a cobble or boulder ~s pushed ahead or aside and the finer material troves into the displaced volume.At the other extreme,a small portion of the fine fraction was lost in the air vented from the cyclone and ~n water ~ overflowing the sample collection bucket.The air used in the reverse circulation system has a tendency to dry the material as it was troving up the pipe to the surface.This action increases the chance of losing fines through the cyclone. 4.DRILLING PERFORMANCE - Early ~n the program the 5-l/2-inch drive faulty welds on the threaded pipe ends. pipe sheared because of Drilling of shallow boreholes m the reI ict channel cant inued with the 9-inch pipe while the substandard 5-l/Z-inch pipe was being rewelded. Excessive build-up of skin friction along the drive p~pe walls limited - real is tic penetrat Lon to approximately 300 feet.Deep holes required additional air capacity and special additives for the air to prevent the cuttings from freezing in the bottom of the drive pipe.Also,the deep hole required several changes between hammer and C.S.R.rotary which generally caused caving of the hole due to the removal of the - drill string during changeover.In the two deeper holes drilled,the B-6 - - ..... - ..... borehole wall deteriorated enough to allow the circulating air to pass along the outside of the drive pipe rather than up the inner pipe.The drilling equipment limitations prevented the scheduled drilling and 1n- sta11ation of test wells. Occasionally,when shallow cobble and boulder zones were encountered, the drive pipe was deflected sufficiently to require redrilling of the hole.Deeper cobbles and boulders wou1e!bend the pipe,but the soil along the pipe would provide enough support that the pipe sections at the surface would not deflect.As a consequence,in several boreholes, the coring of bedrock was precluded due to the difficulty in passing the core barrel through the bent drive pipe.Other cobble/boulders halted the penetration of the drive pipe which also required redril1- ing • The hammer drill rig penetrated very well while drilling shallow holes (less than 200 feet)and in water bearing sands and gravels.Having the drilling and casing combined in one operation provided a rapid, stable borehole.In the river channel,particularly,the hammer drill rig provided useful information in a limited amount of time while penetrating difficult subsurface conditions. B-7 - APPENDIX C -BORING LOGS 1.BORING LOG NOMENCLATURE 1.1 Unified Soil Classification System 2.BORI NG LOGS 2.1 River Channel 2.2 Relict Channel APPENDIX C BORING LOGS 1.BORING LOG NOMENCLATURE Notes: 1.Hammer drill blow counts are for variable energy. 2.Ground surface datum for river borings is for the ice surface. 3.Hammer drill sample cuttings were taken,except where split-spoon samples are noted. 4.Disturbed samples were taken with 2"and 3"split-spoons with a 140 and 300 pound hammer falling 30"and 18"respectively • .Soils: Grain Size:Unified Soil Classification System -- Boulders >1 foot Silt 0.0039-0.074mm Cobbles 3 in -1 ft.Clay <0.0039 mm Gravel Coarse 16-64mm Fine 2-16mm Sand Coarse 0.5-2mm Medium 0.25-0.5mm Fine 0.074-0.25mm C-l Density: Very Dense Dense Medium Dense Loose Very Loose Consistency: Hard Very Stiff Stiff Medium Soft Very Soft Moisture: Saturated Wet Moist Damp/Humid Dry % 100 76-99 51-75 1-50 o N Values (Blows/Foot) >50 30-50 10-30 4-10 0-4 N Values (Blows/Foot) >30 15-30 8-15 4-8 2-4 0-2 Comments voids filled with water visible signs of water varying degrees of wetness - Color: Munsel Color Chart (wet condition) Particle Shape: - Angular Subangular Subrounded Rounded C-2 Gradation Graphics: Gravel t cobbles Rock: Fracture Spacing: Massive Slightly Fractured Moderately Fractured Closely Fractured Intensely Fractured Crushed Strength: Very strong Strong Moderately Strong Weak Friable Plastic Finest silt and clay Feet )3.0 1.0-3.0 0.5-1.0 0.1-0.5 0.05-0.1 5 m~crons -0.1 resists breakage from hammer blows t will yield dust and small chips withstand a few hammer blows but will yield large fragments withstands a few firm hammer blows crumbles with light hammer blows crumbles by rubbing or breaks easily in hands penetrated by fingers C-3 Hardness: Very Hard Hard Moderately Hard Low Hardness Friable Soft cannot be scratched with a knife scratched with difficulty,often faintly visible little dust. readily scratched with knife, considerable dust and visible. deeply gouged or carved with knife easily crumbled or pulverized,too soft to cut with knife plastic material (grooved by fingernail) C-4 - .... Abbreviations: Engineering Properties: Mlc Moisture Content LL Liquid Limit PL Plastic Limit PI Plasti~Index NP Nonplastic SS Split Spoon Gs Specific Gravity K Permeabi 1 ity Geologic Properties and Nomenclature AND Andesite DIO Diorite Plagio Plagioclase Bio Biotite Qtz Quartz K-Feldspar-Potassium Feldspar K-feld Hornbl.Hornblende Fe Iron Mag Magnesium PY Pyrite Kaolin Kaolinite Chlor Chlorite CaC o 3 Calcium Carbonate Fract.Fractured Frctrd Weath Weathered Unweath Unweathered C-5 ---~-------,----------------~-----------_._-------- Alter.Altered Unstd Unstained Hrd Hard Mass Massive Strg Strong Xyln Crystalline Mins Minerals'"""! Pseudo Pseudomorphs Reheal Rehealed ~ Jt Joint ,jj' ,.1 5) Coat Coating F.Grain Fine Grained Med.Grain-Medium Grained General Abbreviations Ii!Ii!i'I m Medium It Light frzn Frozen drkr Darker ~v Very mod Moderate dcrs Decreases modt prbly -Probably occas -Occasional lmtd Limited pc Piece fr Fresh sl Slight mech Mechanical max Maximum brkg Breaking ml.n Minimum IIl!l! inclu -Inclusions consid-Considerable C-6 ~ I - - 1.1 Unified Soil Classification System The unified System classified all soils as coarse or fine-grained based on the larger amount by weight retained or passing the No.200 s~eve. Coarse grianed soils (sand,gravel)are further classified both by the uniformity of the gradation of the soil (GW,GP,SW,Sp)as well as the amount and type of fines (silt,clay)fil-ling voids in the coarse soils (GM,GC,SM,SC).Fine grained soils are further classified according to plasticity (CL,ML,CR,MH)as determined by Atterberg Limit tests. Thus,grain size analyses and Atterberg Limit tests are used to class- ify all non-organic soils into a group symbol Which defines the texture and plasticity of the soil.Each group symbol indicates that a soil classified as such should exhibit a broad range of the engineering pro- perties of strength,compressibility and permeability.This range is further defined if a measure of the relative density of the soil and moisture content are provided in conjunction with the group symbol. Given the group symbol,.relat ive dens ity,moisture content,and obser- vations of particle shape,it is possible to predict engineering pro- perties and anticipated behavior within an accuracy suitable for many engineering purposes. C-7 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPEMENT Sheet --.L...of --.2.... Date _ EXAMPLEBoringNo Feature Coordinates:N _ E _ Logged by Angle (from Horizontal)_ Bearing Date Started _ Date Completed _ Ground Elevation _ Rock Elevation _ Total Depth Ground-Water Elevation _ Remarks FiliJit1!111f!l . LL3J':B120 BIll i CL M1C75% 4l19~~.--t¥Em.-.,?-P,%,..... not visible or _'pa,??-f-~g 412 (),t> sd.eve mbre'than;50% ---v:i.sIbfFC;Fr e;-=- •tliinedi on,IIJ20(),'-S~E:~;J-,.-.-:+~- !.! c .S! «i 'ECDe 2 '0 .5 Soil Description j --'"\ •.,,w.,_~,~~"_"~,,_~,,,_.~,o_,~,,, ~'",:,.:'_.J,~,,~':'__:.'_:_._,.f __''"'.,,j _~,:_;_:..::.....~,',::;',','.:,'"__;<f6arbe;Gl:~ver.:l TeXt¥re~.prefix.fori -~:c6aj'S~-:or~-m,.fine.s;!·:ire1:i$Tqi1;r--~'+ m~l~·~~·~~~~~tt~te:~t~kl:r~.~~t~·ellara,cter1st;ick,'(....i'.i'.... "'-"1 ",,-'-•---",,--,"--,-,.-,""·A-~··I 1-"""j--'. ~~.'j , I.i."i'.':...................1 i ..".,I·,~~~:.~~~~~~~~·~;i:~~~t~;Q-ik~~~';;fE~11t_~~L· s1t'i::u~ture!,.orgiand.csl,:geo\J..ogic:charact:;- :erct.sf'i¢s,!-'-'~'+'-:T--'--:-r--'--I=----',-r:"-:'~T'~---- .i ..·· .=---/.'-~-f-::---.;r'---C+~.~;,L.+~'~~T,,·i-1:~~f~~'~··-:"~+'·+"-~-~"'~" GM1 12 3SS 26 29 c ~°CD c·~ J:0 0-CD-za.:::I::J:!y_C _Ill CD>-oll):E CI'E..m a.e -II)111:::1 E II)-l-t).C1>a.oIll>Cl o a.~0 Co"'-~...!!....co!!._u en.5 Ec CDy !!:!.a:"'Ill OCD ....11)CleniDa.a: ~, ,- - ..... .... - - - Boring No.Sheet __1__of 2 SUS/TNA JOINT VENTURE Boring No EXAMPLE Feature Coordinates:N _ E _ Core Sizes _ GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)_ Bearing Date Started _ Date Completed _ Total Depth Sheet -----2-of-----2- Date _ Ground Elevation ~_ Rock Elevation _ Overburden Thickness Ground-Water Elevatioo _ Logged by _ Graphic Log C 12.c .S!>-Ql Q ..~g>0.';::l0tiGI>'0 ~....IQ~;2 at!!!.::A iii 3 6 9 12 Classification and Physical Description :a ~ Q,0 l!!0 <;J E!: Ii Ii U U :u ..Q E ::l Z )(o In c .S! iii C GI E 2u;.= Remarks ~ I I n Boring No.Sheet __2__of _2__ 2.1 RIVER CHANN EL BORING LOGS SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet_1_Of __2_ Date 4/]2/83 Boring No DH83-1 (River y~Angle (from Horizontal)900 Feature D/S Cofferdam Bearing~, Coordinates:N 3,227,912.0 Date Started 3/3/83 E 747,211.2 Date Completed 3/12/83 Core Sizes HX/NX Total Depth 91.0 Ground Elevation __=-1.....,4...:..=64-,--,-.-",0__~_ Rock Elevation __--=1'--',...,3""8=-6=--'-0=0 _ Overburden Thickness 62.5 Ground-Water Elevation_---,-_ Logged by MSC/SEW/DAF 2of c ~...~a QI Q ,g ... E C0::I QI !E z E Remarks Ii l(2 c.)0 ;;;!Xl .: J_:m~L:Q9!.~il]~~Jd:i~L~d::···· l'y~,r~rl:1a,rq 'dri1!Hng N .-< Borina NopHa~~l Sheet 1 Classification and Physical Description AD . Graphic Log 50 C J:.2 i;;o ~0.';- QI>'0 UQQI::Iw_.;... :J en - ..... .- .... SUSITNA JOINT VENTURE Boring No DH 83-1 Feature DIs Cofferdam Coordinates:N 3227912.0 E 747211.1 Core Sizes HX/me GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)__~9-",O,-o _ Bearing Date Started 3,LII-Ol.L3..u-1....8 ...3 _ Date Completed _~3oL/L1.....2...,/'-'8"--3L-_ Total Depth 91.0 Sheet 2 of 2 Date 4712/83 Ground Elevation 1464.0 Rock Elevation 1386.a Overburden Thickness _.....:61L2.............5 _ Ground-Water Elevatioo -,--_--:-_ Logged by ----"-M""'S=C !SEW /DAF Graphic Log C .e.2'Q.c; lD>CCil @ ··7::.0:: c: U ~;;:8:c 0 .a <0c.0 E 'E Classification and Physical Description ~":::l Q) <;l !!:z E Remarks Ii Ii ><:::l... cj cj 0 'liiI:D .5 Rnrinn Nn nWR 1-1 C:O"ftA'2 2 g ~. I Angle (from Horizontal)90 0 Ground Elevation 1 ,47 a•6 Bearing Rock Elevation 1,424.6 Date Started 3/13/83 Overburden Thickness ---'4:....=1:....:.:....=5:.......=F--=t:....:.~_ Date Completed __-=3-:.-/:....=1:....=5'-'./--=8--=3:-Ground-Water Elevation _ Total Depth 64 •a Logged by SEW /MSC - SUSITNA JOINT VENTURE Boring No DH83-2 (FF) Feature U /S Portal s Coordinates:N 3,228.775.3 E 747,566.6 Core Sizes HW /NX GEOLOGIC LOG WATANA DEVELOPMENT Sheet_1_of_2_ Date 4/12/83 467Qft.IDtorite.med;gray;med.Xyln .~•__..L _·Ie ft-·.Lpfigt6;-'tr~tl!tbt:en~e';:'s~m:e-'b;to·'&-qtz .f~CaCo Fresh Massive...'. .. I50 -Graphic Log c u ~...~c :c 0 CP.c ...cO >-CP CI.C e c...Q.~CIl ::I ..0°..::I Glr-CP>"0 ti Classification and Physical Description C?~z e RemarksCCP::I iii ;..a:a:><2-:J W c.:i c.:i °'1i)III .: ..... - - Borino No.DRS 3-2 Sh9At 1:nf 2 SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet 2 of 2 Date ~2/~ ~ I •I -, i 22BorinaNnDH83-2.c::h ....t Graphic Log cu~-.2C:c "QI -;l!!..Q..c .2 :>-l!!a.c E ~'Q.';~::I .ag <lI 00C;;:::I QI QI >Ci (i ~....I Classification and Physical Description a::z E RemarkscQI-5 ::I -Ii ~.$~-II.)( :i en 0 Q 0 en503 6 9 12 IXI .E ..'+._;....-...;-,. ~......-_.'. i r -SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet _1__of _3_ Date 4/12/83 Boring No DH83-3 Feature Seismic Line Coordinates:N 3,226,820.9 E 745,565.9 Core Sizes HW INX. 90 0 Angle (from Horizontall _ Bearing _ Date Started ~3L,/.=.1.::::.5L,/.::::.8.::::.3---_ Date Completed __.:::.3.!..../=.2:::.5!-/~8~3 _ Total Depth 126.5 Ground Elevation 1_4_6..,..0_,_4 _ Rock Elevation 1_3_6_7_._5 _ Overburden Thickness 83.3 Ground-Water Elevation---=-::.::-::.::-=--_ Logged by SEW/MSC/MJS No waiter return Graphic Log c (,l ~Gi .2'2 :c 0 a;e D.c .51 >.l!?a.0 E 'Ea:a;Cl ::J =8'l!!00 ::J CII lD>'0 U g~Classification and Physical Description q:J ~z E Remarks OlD ::2 It 2@a:::a:::)( :J iii 0 0 0 Ui 3 6 9 12 lD .5 - - - Boring No.Dh8 3-3sheet _~1,,---_of _-=3:-- SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet_2_of_3_ Date 4/12/83 Boring No DH83-3 Angle (from Horizontal)9....,O"'-o _ Feature Sei smi c Line Bearing Coordinates:N 3226820.9 Date Started 3/15/83 E 745565.9 Date Completed -.;l3,+/..2,.}5+1-G8~3------ Core Sizes __H.uJOjw'-#-I...,NXLlJL-Total Depth ---!.-1""'2""'6......~5J._------- Grou nd Elevation __-=1:....:4'--'6=..::0:...:.'---4-'---_ Rock Elevation -=1-=3-...:6-...:7-...:.-...:5'----_ Overburden Thickness 83.3 Ground-Water Elevation _-_-_-_ Logged by SEW IMJS - Graphic log cu~...2C:c 0 QI 'liiQI 11.c.2 >-l!!..c.c 'Ea.:;CII ::I ::10 ~00g.s QI QI>"0 U Classification and Physical Description <;l ~E Remarks ""!co!!!;::I ..Ii a:::l I!!!...IJ.><.. ::i iii c..i c..i 0 0; 3 &9 12 III .s Borino No.DH83-3sh~~t 2 nf 1 SUSITNA JOINT VENTURE Boring No DH83-3 Feature Seismic Line Coordinates:N 3226820.9 E 745565.9 Core Sizes llW/NX~-------- GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)__....;9:tJOI./-°_ Bearing Date Started 3/1 5/83 Date Completed _34 /'-"2;..54 1'-'8.....3-'-----_ Total Depth 1 26 5 Sheet _3_of_3_ Date 4{12{83 Ground Elevation 1460,4 Rock Elevation 1367 , 5 Overburden Thickness :::8.",3'-',.::-3 _ Ground-Water Elevation-__-_-_ Logged by SEW IMJS ..- - .... - Graphic Log c CD..c ,2 >-l!!:SCIe.G;CI :l0U -0 CD>'0 ~....o..!!::2 at!:!:!.::i u; 3 6 9 12 c u ~....2:c 0 CD fti.0Q.0 E CIII0ClassificationandPhysicalDescription ...:l CDq!!:z E Remarks a::a::)(2 0 0 0 ';jm.E Boring No.DH83-3Sheet 3 of 3 - SUS/TNA JOINT VENTURE Boring No DH83-4 Feature q,Dam Rt Bank Coordinates:N 3 t 226 t 978 •a E 744 t 958.5 GEOLOGIC LOG WATANA DEVELOPMENT 1 3Sheet__of __ Date _ Ground Elevation 14 75 • 2 Rock Elevation 1 4 5 9 • 6 Overburden Thickness 20 • 0 j. Grou n doW ater EI evat ion -=-::1;-1r::-:;.-:;4-:;;-4-=---__ Logged by SEM/MSC/MJS Graphic Log c l.l ~Gi .2C:E "asCD..Q .c::.2 >-OIl ...a.C e cClI....ag ca 0a.ca 0 =...=OIl-OIl>'0 (j g,.J Classification and Physical Description ql e:z E Remarks COIl ==...Ii Ii )(:::Ig...u..::: :i Ui ti ti 0 III3 6 9 12 ED .E ~..J - ,'.':'}Wea .;.......'..'......._I..•~~~~-~q~~~--'i'o~ss;-·'prbI5Fsami·m.!~~rjJalT-••· ...•.134-.6;"'136-.4I ;1\1l.terl Dforliit'e,k;wealth.•.••.,•._~_"C'-'T ..•._.-.'"...1t ,~_-_ ..dleco1lljPP'I:3,e,J;gp,!fjesrt::al:i,Il J 110w ha;rd ~tkf-~~~:"~<F.:x.YlIl,;sl,.bl1eachie'd:t,;cjrose ;f.ractJ FJ·,··::;·;o:·.6Eq:l.'.'i 1ffiir~~T'TIiQd.Ffsfr.ong':I=-"·- FJ •·39~4J44.5MterlDioriiteJ Ifg.ra;fn ;Q;]a¥-..-·.t't:'irreT·d:arl~3Itzr;ll~u-}ll'a!f:iC:S ,j- 'cJjay .l:np<:!'-c!lpselfractl,g:raJd'esqo biello'W F E!__...._.~.!Dilixift e.-JS1:....·dirkr more-lIlBi'li':"....clo~.~..f'radt~Festa:LnoIlj;t.~,..cla CaCO').pn otihers }W!Kaoliniz,ed feldslpa!reL,_.....,~-,,'''''~~~~1>~'~',-":-,,"'"...,'"",,---.~--=~'---------~---('~~.:-,,,.-,~,~~-,~",~+.,-~--,,,..""-;-~··'-~-~O'f"~""T"-~"·' FM •.,44.5-49.SDio'r;JJee gtleY,som.e ella CaC03 on j t's d'crs wi dlepeh,:mod....elose Boring No.DH83-4Sheet __1_0.__3_ SUS/TNA JO/NT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet_2 _of __3 _ Oate _ Boring No DH83-4 Feature t Dam Rt:Bank Coordinates:N -----.;3h2~2r.-16~9'h71_.f.8~•._10J_--- E --+7<+/1<+/'~9~589-r..5~--- Angle (from HorizontaJ)---,4",-,5,,--0_~____Ground Elevation 1475 .2 Bearing 350°Rock Elevation 1459.6 Date Started 3/28/83 Overburden Thickness 2-'-'O~.-'-'0 _ Date Completed 3/30/83 Ground-Water Elevation ] ]~•.=t4,--_ Core Sizes ---PlNXIft---------Total Depth 116.5 Logged by SEM!MSC IM.IS Graphic Log c ~!.cO >- Q.~Cl ::I ~~°UQ1>"0 g..Jco!!.;::I ~ !!:!.~LI. :.::i in 3 6 9 12 .45° .~5 60° 60° .60° 90° 100 Classification and Physical Description c: (,l :1!Gi ~:c Q .Q llSCo0EC~0 ::I QI t;l !!:z Ea:a:)(2 U (.)0 U;al .5 co-" Remarks •• Boring No.DH83-4sheet 2 of_3 DHS3-4 SUSITNA JOINT VENTURE Boring No Feature _~t.~DLLa<:IJmLl1-.J:\R.Lt~....LBualln.uk""-----­ Coordi nates:N _3;)..2,,",2,,-,6o.:9:1-7~8o..-lJ.O---- E --J-.7-,+,44,+-;9~5J.I;,81-..-J5---- Core Sizes ...cNuX~_ GEOLOGIC LOG WATANA DEVELOPMENT 45 0Angle(from Horizontal)__-=~_ Bearing ----=3~5"-"O!_0 _ Date Started -""'3.1-/1.2.>.<8.1-/.>.<S....3 _ Date Completed __3;).,.1-13.lll0.j.../.o8w3L-._ Total Depth 11 6.5 Sheet __3_of_3_ Date _ Ground Elevation 1475.2 Rock Elevation lq59.6 Overburden Thickness ...2HOJ-;•..-IOJ------- Ground-Water Elevation-:ll:-:llb-,."'4.....-_ Logged by SEM/MSC/MIS Graphic Log cu~Qi .EC:a 0 -;CD CD .0.c .51 >-"-:SCI Q,c E 'EamCI:l l!00-0 :l CD CD>"0 (;g ....Classification and Physical Description t;I e:z E Remarks c~:l;:...at Ii Ii )(oS!:!:!.~iii (.)(.)0 Ul3 6 9 12 ID E.... - - .... - Borina No.DH83-4sheet 3 of 3 ---' SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of _3_ Date 3126/83 ..... Boring No HD83-10 (River H)Angle (from Horizontal)__-::...9.::::0_o _ Feature ct Main Dam Bearing --==;-----;-,--_ Coordinates:N 3226920.3 Date Started __---=2:..L/.,.:2::.,:0:..L/.,.:8::..::3:..-.._ E 745009.1 Date Completed _--=2::."/--=2:.,:1::.!.I--=8:..::3:...-_ Logged byWHBwJ:J.C~.-J:lBi.LL...JI-,•..--.J:NlUB)lHJ.,·.,.........J..1Fc.."RD//4..LEM.DAF Grou nd Elevation __1=-4.:=...::-5~9-,-.-74 _ Rock Elevation __--=1.::::3-=6-=3:...:.:.--4=---_ Total Depth 119 •5 Ground-Water Elevation-=-::..:-::..:-=---_ .HAM,.CO •. .r!pe ~Cl ~.l<;e(:l.~~~L . ft •.,rno\\,e hole. reqrill: 5~~""HAMj.CI i -i 'J c .2 1U CE Remarks oS UI .5 i· 5-12%silt.dark olive grey.rounded to sUbrounded --SaIDit....y-GRAVEt·-'1.-=ss-than·l5%··'~n·6""·'-···li·.·...,..'.,.,',.....',".L.I-.'"0 ••0 .V grey •.angular ito subangular.:fine to __c-oat s4.with,(J;OBBLES..and.oc.caSi6.naL ,bouldersl ...i GM 8M GP GM GP GM GW GW GM .- ...... - 50 Boring No.HD83-Sheet 1 10 of 3 Boring No _-=H=D:.::8:.::3:....-....::1~O::..-(:>.:R::;~:::.·v.:...e:::.r::.......;H:=.L)_Angle (from Horizontal)9=--O:::....-o _ Feature It Main Dam Bearing Coordi nates:N _-=3:.=2,-=2,-,,6:..::9..::2~O...!.0=..3____Date Started __--=2:.L/,=2:.::0:.L/,.::8:,.=3:....-_ E _-..:.7--'4-=5-=0-=0..::.9..::.0-=.1 Date Completed _-=2:..!./-=2:..=1:...<./-=8-=3'----_ Logged by WMB,RT T,NBR,.TEB ILEM,DAF . SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 2 of_3_ Date ?;f26/83 Grou nd Elevation _---:1~4~5"-9C-.:..."4 _ Rock Elevation __--=-1-=-376-::.3..:."-::4 _ Total Depth 119 05 Ground-Water Elevation_-_-_-_ ....... I I!"'II i, ---.t~::\mii;;::!::.?!!~JZI Hard drilling,81 f£~ ~t'·\S1.~~ Jgtt~_9f,~at~r at 75"5 :fft. c .2 (;j 'EE Remarks 2 'lii .5 GP GM GW 18 17 12 c ~OlD 'E.'tI .c .2 0-0)-Zo.==.cl!!u_c _GI 1Il>-Oo,n :2l:D0:;a.>-cuID:::I E4i -~°ci l:D>0.0 Soil DescriptionlD>.2'8 0.'tI Coo~GI-Ec ~...CUu ~.... ~0::lI.I.5 GIGI 041 ....0Il <:I r./)iDa.0:: GP 10 GM GW GM 11 Boring NoJ1D83-Sheet _...::2=--of --=.3__ 10 SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet_3__of_3_ Date 4/8/'d3 qnring No HD8i-10~River H)Angle (from Horizontal)90 0 Ground Elevation 1 ,45'3.4 Feature EMa on Da-Bearing Rock Elevation 1,363.4 Coordinates:N 3226920.3 Date Started 2/20/83 Overburden Thickness 92.5 E 745009.1 Date Completed 2/21/83 Ground-Water Elevation Core Sizes NX Total Depth 119.5'Logged by NBR.r-JFB,DAF .- - ..- - Graphic Log Classification and Physical Description cu::l!...2:E 0 CD C;.aCoQE CIIIa..:::l CD<;J ~z E a::a::)(:::l ~0 0 '0 UIIXI.E Remarks Mi$}:;a,tch.Meclta.iticalbr~~~hg~I;a,jIq..··.grtm.g~ =f~~T~=I?Iff:···r·rt:rrr··i··· :'l "_j.·~hac·ttYesrkpp to:be;mechanica.1:df :':~:il.idenceLdLg.I:in.d-tln '-'~I-"T . ..'........''.I tfailYfra.ctJ.1res:a.ppea "pLb.etmech~lIica.il.J-.Y:':. .!::.ausep.,:te!La.tedLtp hi'eakkge;ah.Oi::l.g···~itgh' '7"ThafiiraY'=j"EsT:=-t'fo'. g:rinding.•·· :'_3L_a~Q...JjjjSs,.@t!11:l~5.' 'ft ';. I Boring No.HD?~-Sheet _-,3"---.of --=30-_ ....-'-" WANATA DEVELOPMENT SOIL BORING LOG SUS/TNA JOINT VENTURE Boring No HD83-11 (River A)Angle (from Horizontal)90 0 Feature <L Main Dam Bearing -=~'----,:-:------- Coordinates:N 3226653.1 Date Started 2/21/83 E 745064.3 Date Completed --=2'"'-/.=.2.=.2!-/-=-83==--_ Logged by WMB ,BL J ,NEB,lEB /LEM-,DAF Sheet 1 of --3....- Date ~26/83 Ground Elevation _..----!1"-=4:o:..,5~9"__"_'.1"'--_ Rock Elevation __--..::-13=-=85~.~9 _ Total Depth 89 .4 Ground-Water Elevation _ Remarks 5~0 HAM,CO, Pip.e cocked '@ 12.l:-.5··Ftl:"C1~ov~ai--. ho~e,4!ti.mesl,re -dtilE!::'_::~"'--'~':.". Hard D:rilling, 41.5 Ft:. _~.m;_~.L'_NN~N~~~t-':_~_,,_~~L__i~..~_+_~-+~_.__._:__~t~_~..__~..~L_~~~_~.,_,v=,o ,1 1 --.Sap;~Ttj'ltfYW'T5;-lZ(o-.cLatreY-····Sd:rf-;-·-wrf1i·­ COB'j3LES,1 sat:uFated~.da.rRgre¥,rounded ~t.o+$llJirQu.hcIec4-.,_..J __..L_.._'-._._''_.'.. ,sandy .GrtAVEL lWITH.:coBinJEs,..d-12%lsjilt ..~a;~;t"a t.~~AalS1¢,q~1v~·2~¥ey ,.'l1;o~n,d~d--~" ....t.q J~~b~9lJ;n.dt=cd!".····:6:i:ri,ejt;o lcqa:r;~~i 'q~q~­ --S-~-;;;_·t-'-+"-~-·t·~-i-·---·· SP SM GW GM 1 2 4 3 5 6 7 50 C 3:_oQl 'C."1:1 .c .S!QI-Za.=:.cl!!u.2c _Ill OU):Eel--a.e QI>--QIa.<IJ 1%1=-I-(,).e1>g-,g Soil DescriptionCD>01 0 ECD a."C 0 Co<IJ-3:..c.!!._(J (/).5 Ec Qlu ....-~a:1lI<IJ OCD ...IQI CJ (/)iDa.a: - -. - - Boring No.HD8 3-Sheet ----'I=--_of 3 10 SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _2_of ------L Date 3/26/83 Boring No RD83-11 (River A)Angle (from Horizontal)__9_0_o _ Feature <t Main Dam.Bearing Coordinates:N 3226653.1 Date Started ....2LI""-2"'-lL/~8>L3 _ E 745064,3 Date Completed _~2..L1-"2,,,,2.L/.l.!.8..l3 _ ~ggedby WMB,RLJ,NBR,JFB/LEM,DAF Ground Elevation ---..:_1_4_5_9_,_1 _ Rock Elevation __--1.]..J3~8,-5L.....:9L-_ Total Depth 89 4 Ground-Water Elevation _--=.;=--_ - Remarks c .51 1ii C CD E 2 '0.: Soil Description GP GM CD-_CD Q.i::: ECDca-li)': ~-_c m=.~8 II: Boring No.RDa 3-Sheet _2__of _3__," SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet L of --3.- Date ~3LJ.!-"2......6f..l-!-,,,8c...1.3_ Boring No HD83-11 Feature £Dam AXIS Coordinates:N 3226653.1 E 745064.3 90 0Angle(from Horizontali__'"-=_ Bearing -===---_ Date Started __...2J.1...2L.!1,J.!----'8""3L-_ Date Completed ------ll2L1!-'2"""2'-'--/~8~3L.-_ Core Sizes Total Depth 89.4 Ground Elevation 1459.1 Rock Elevation 1385 .q Overburden Thickness ---65-.-2------ Ground-Water Elevation ..::-;.::-;.::-:.-..-_ Logged by WMB,RLJ ,NEE,JFB !LEM,DAF .... ..... .... C .c .2 '6:; al > Cal @ LOa Graphic Log !! ::l .a go c:;~..... 2 Li:in 3 6 9 12 cu":f!.-.E:c a al 1;;.cc.C E 'EIII0-::l alClassificationandPhysicalDescription<;J e:z E Remarks Ii Ii >C 2 cJ cJ 0 inrD.= SUSITNA JOINT VENTURE Boring No HD83-12 (River B) Feature t Main Dam Coordinates:N 3226694 04 E 745072 0a Logged by WMB IRLJ ILEM.DAF SOIL BORING LOG WATANA DEVELOPMENT Angle (from HorizontaIJ 9'-'-0'-o _ Bearing Date Started --'2 1'--'2"-'2 1'--'8"-'3"--_ Date Completed _--'2 1'-'2...,2 1'--'8"->3<-_ -- Sheet _1_oL3_ Date 3/31/83 Ground Elevation _--==1=-4~5,::-9...:0,::,0,----_ Rock Elevation 1_3_8_2,::-0_0 _ Total Depth 87 0 5 Ground-Water Elevation _ C 11:OlD 'E.'tl.e.g lD-za.:I::.el!!CJ0-_Ill_c lD>-oU'):E OIa:a;In:l a.e -CII ECII -l-t,)-01>a.oCII>01 0 a.'tl 0 Co1Il-11:,-f!....co!!__t,) cn.E Ec CIIu !:!!.a:III III OCII ....CII "lIJ iDa.a: .... ,~ - 1 2 3 4 5 6 7 8 Soil Description GP GM I-~---_.---~--~.,_____L~---·'_.--t-----'-!_--.~--+-,.---.-.-r.--.---r+---------I GP GM ~-----,-----+·c---------r--,.-,.--+----------·--··--------t_~-·---,-·._~-_.-.,.-.-...-. c.g ia'ElD E E '".E Remarks Boring No.HD83-Sheet ~1~_of 3 1 "I SUSITNA JOINT VENTURE Boring No HD83-12 (River B) ttl Main DamFeature Coordinates:N 3226694.4 E 745072.0 Logged by WMB,RL.I /LEM,DAF SOIL BORING LOG WATANA DEVELOPMENT 90 0 Angle (from Horizontall __---=--=---_ Bearing _ Date Started -=2:.</.....2=-=2:.</---"8""3'--_ Date Completed _-----'2=.,,1L.!2"-!2::..//'-"8"-".3!....-_ Sheet _2_of ...l.- Date 3/31/83 Ground Elevation _--,1::...4.:.:5~9~.~O _ Rock Elevation __-=1..:::3~8~2~.~O;...----- Total Depth 87 .5 Ground-Water Elevation _ - - RemarksSoilDescription .. ,t--~J~--,-;_._:.;';:l',l,!~:-T.~----;.._•..•~~,---_r-,.-.---.- CDBBLESLAND,BOULDE~S:.--.--\~..__+--.L ..+-"-~+.--.-'+---L'...-----r-.,--. r l'(... ,.l..-...-~f,'~..".-,.__~l-.-~--.:-,l~---.:.,_+_+"'>--"-.-"-...~.~~-i-."_.•_¥.-:-c'··__f"·..-o-t·~··-·--.~~" GP GM "0 .cl!! -GICI>ColDu .....lD I%: c ,~ ~=Owo·oiI:.. OlD iDa. 10 12 11 9 OlDza, lD>--I- a.-cEc 1lI1l1en C .c .2a.,; CD> OlD ~ Boring No.HD83-Sheet 2 of ~3,--_ 1 ? SUSITNA JOINT VENTURE Boring No ~"--~1",-,2,,,----_ Feature ------.L...-Ma.....i.I.JnL...!"D,...a...m"-----_ Coordinates:N 3226694.4 E 745072.0 Core Sizes -------NX- GEOLOGIC LOG WATANA DEVELOPMENT 90 °Angle (from Horizontal)__~_ Bearing Date Started __~2.L/~2~2.L/.::!8.:::!.3 _ Date Completed _-'2=..;/'-'2""2=-/'-'8"'--"'-3 _ Total Depth __~8~7,--,.!...:5~_ Sheet_3_of_3_ Date 3/31 /83 Ground Elevation _-:1=-:4:-c5;:-9=-=-.-::-0 _ Rock Elevation 1_3_8_2_.0 _ Overburden Thickness ~6L.9,-,.,-,,5,,----_ Ground-Water Elevation _ Logged by WMIiI ,RLJ/LEM,DAF ..... - .- .... Graphic Log c-Gl J:.2 >.Gl .. CI .. =g'a.-a;:I0UGl>"5 g...lC.!:I::.... !!:!.u;u. ::::i 3 6 9 12 cu:>!!..~:c "Gl.c '"Co c E C'"0 Classification and Physical Description ..:I Gl <;l I:r Z E Remarks ri ~)(2 0 0 0 UiIXI.5 Boring No.HD83-Sheet ~3~-of 3 -SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _2_ Date 3/26/83 G round Elevation _-:1=-:4:-::5:-8;-0=-:5=--_ Rock Elevation 1_3.".7-=-4_0-::5 _ Total Depth 8900 Ground-Water Elevation _ 90 °Angle (from Horizontall __-=-.=:..-_ Bearing Date Started -=-2"'-;-/=.22:::-/:..;-8::-3=-_ Date Completed __-=2'-'-/-=2'-"3:...<.../-.:::8-=3 _ JFB,r"EM Boring No HD83-13 (River G) Feature lb Main Dam Coordinates:N 3226856 03 E 74502302 Logged by WMB,RLJ,NBH, c ~asc ~Remarks 2 iii .5 2 8 7 SP 1 c ;=o 41 c.00 ..cO 0-41-zQ.;:,:::..cl!!(,J_as Q.~_·c Q.i::QI>-OU)-QI :.cOlID;:'EGI -~(,Jc:i Dl>Q.o Soil DescriptionQI>.218 Q.oo CoC..!as-;=..l'!!~cn.5 E C Qlu !:!:!.a:~as 041 ~Ql CImiQ.a: ..- SP 5 8M ~ 6 3 ..... GP ..-- 4 GM ..... ..... Boring No.HD83-Sheet 1 13 of 2 ~ I - - Sheet __2_of ~ Date 3/27/83 Hammer to 89.,0, CQI:iaBarrellwon' fiodown drive Remarks c .2-;; 'ECD E 2 Ui .E Boring No.HD8.3-Sheet ---=2__of 2 WATANA DEVELOPMENT SOIL BORING LOG Angle (from Horizontal)9_0_o Ground Elevation _----.:1::...4,:.,8=-57-=-.~5---- Bearing --:-..-=".....-,...-=-Rock Elevation 1_3--=7--=4....:•....:.:5,----_ Date Started 2....::.7-:-2_2....::.1-:-8_3 Total Depth 89•0 Date Completed 2/23/83 Ground-Water Elevation _ GP GM GW GM 13 12 11 10 "'2 ~OlD 'E."CI J:.~0-GI-zQ.:::I:::J:!u_c _I'C! Q)>'OlD :EI:I)Q.7Q a.~-GI11:1:::1 ECD -~0c::i 1:1»a.o Soil DescriptionCD>.2!S Q.'O CoOO!!I'C!-Ec ~...CDu ~..l !!!.a:l/).E I'C!I'C!OCD ..lQ)CI (/)iDa.a: 9' ~.1 ~~£1JJ6j~~mJ SUSITNA JOINT VENTURE Boring No HD83-13 (River G) Feature <L Main Dam Coordinates:N 3226856.3 E 745023.2 Logged by WMB ,RT "T ,NBH ,.TEB II ,EM SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of _3_ Date ---sr27/83 Boring No HD83-14 (River DD)Angle (from Horizontal)__~9LO~o Ground Elevation 1464.8 Feature D/S Cofferdam Bearing Rock Elevation _ Coordinates:N 3228343.0 Date Started 2/23/83 Total Depth 57.5 E 747142.4 Date Completed 2/27 /83 Ground-Water Elevation _ Logged by WMB,RLJ t REH,JFB ILEM,DAF Hard Drilling @ ..33..0 ..Et~. 2 1 50 C C °CD 'E..2~"C -:;.co2 0-~-Zo.::::I:.c!() C _«I 01.0 :COla.'Cii _C o.e CD>'-CIlID::::I _I-o·01>Soil Description II)RemarksCIl>.2'8 ECD o."C 0 Co 0.0 Ec..!!«1-Ec ~...~()f!...l ::::I !:!:!.a::lI.I-=«Ial OCD ...lCll CJ .:::lI.I iDo.a::II) -= 3 GW ro.- t,,· 4 GW""'"GM -5 GW .... - -i Boring No.HD83-Sheet 1 14 of 3 SUS/TNA JO/NT VENTURE Boring No HD83-14 Feature u/s Cofferdam Coordinates:N 3228343.0 E 747142.4 Core Sizes _NXl.llA _ GEOLOGIC LOG WATANA DEVELOPMENT 90 °Angle (from Horizontal)~=-_ Bearing Date Started _--,,24/..j;2~3Lj/,-,8....3",-----_ Date Completed ~2.../,-,2'--L7~/.u.R...>.3 _ Total Depth 57.5 Sheet ----.2....-of ~~ Date 3/27/83 Ground Elevation 1464.8 Rock Elevation _ Overburden Thickness -"Z..;9z...•..J.OL-_ Ground-Water Elevation-__--_ Logged by WMB,ELI,RER,.TFB II.EM,DAI Graphic Log c CJ ~....S!c :c "CD iiil!!,g.c .2 .>-CD C.c E 'ECl...:::ICl ~0a-;0 :::I -0 :::I CD CD>0 U ~~Classification and Physical Description <;'EE z E Remarksc~oS 2 ...Ii Ii )(2!:!:!.iii LL.0 u;::i 3 6 9 12 d d I:Q .5 ·-,-,··~_·t·_._.,...-'_;..............._-,.0··.••. mech . Boring No.HD~?-Sheet 2 of 3 - r !""" U~I-~IC' SUS/TNA JOINT VENTURE Boring No HD83-14 Feature U/ S Cofferdam Coordinates:N 322834.° E 747142.4 Core Sizes __N~X,--_ GEOLOGIC LOG WATANA DEVELOPMENT 90 °Angle (from Horizontalj ~~__ Bearing Date Started -'2"-'/L:2=:.;3~/L:8"_'3~_ Date Completed __2==-/~2~7~/'--.:8::..:3~_ Total Depth 57 .5 .- Sheet3 _of _3_ Date 3/27/83 Ground Elevation 1464 • 8 Rock Elevation _ Overburden Thickness ..2....9'-'"'--0"'-_ Ground-Water Elevation _-_-_-_ Logged by WMB,RLJ ,REH.JFB /LEM , ..- I Graphic Log cu~Qi .2C:c a ~!!.a.c .S!>-a.0 E CE.ca CD ::::l Elf l'lI a0UClassificationandPhysicalDescription ...::::l QI QI>'0 :.l...l c;'l e:z E Remarks o..!!::::l.;...at Ii Ii ><S!:!:!.:::i iii 0 0 0 III36 9 12 al .E CX) \0_No_ o N ....-l Borino No.HD83-Sheet 3 -.--' SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT 1 <)Sheet-:r,rzflcr.I-- Date _ Boring No HD83-1S (River CC)Angle (from Horizontall __9::...O.=...-o Ground Elevation 1..:--4:-6::-S=-,-'-:-1 _ Feature D/S Portal Cofferdam Bearing Rock Elevation ..:--1.-'-4-=-3-=:S..:--.--=6 _ Coordinates:N 3228232.7 Date Started 2..:..,/,.::2'--'4..:..,/,..:.8~3 Total Depth 46.° E 747112.7 Date Completed 2/27/83 Ground-Water Elevation_~~_ Logged by REH,JFB,JEP,RLJ/LEM,DAF Remarks Pi~la Cbckladlat'7:iE':'itto~~drhbie r~drilli.. -f;,:~~'-' _.j{~.tej:"~t.etJJ.!:il.a,t ·13.2Ft.: ....M::bS~;l~._.~A.II..I.··_A_~__.._ W4\ter return at 16.4 FL'~-'-'-'-""7'''-''",-'"''~A__~"''b......",_,,._.._:~,,,~.__,m .._ HAM~C~' ,i '~'Bbutaet-a t-3 .IE. m~vedhole'ire,......:=a.~:iif~·I~"·"-·_iJ2.L- : c .2 iii C CD E 2u; .E GW GP GM 2 S 3 4 1 50 -'E'oQ)-~C .".co2 0-GI-ZQ.::::l::.cl!?u_Ill oll)--_C Q.i::Q)>--Q):E OIa.III lD::::l EQ)-~(j.01>0.0 Soil DescriptionGI>01 0 a."Cl Co1lI-~..l!!....co!!.-(j en":Ec GI U I""'"!:!:!.a:III III OQ)....G1 CJeniDa.a: ,~ Boring No.HD£3-Sheet ~l__of -.1-__ 1 r.; SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet-.2 _of_2.- Date 3/27/83 Boring No HD83-15 Feature U/S Portal Cofferdam Coordinates:N 3228232.7 E 747112.7 Angle (from Horizontal)90 0 Bearing Date Started 2{24/83 Date Completed _....2~/....2....7.../.1......8.....3'---_ Core Sizes Total Depth 46.0 Ground Elevation 1465.1 Rock Elevation 1435 .J Overburden Thickness ""2.".4_,.....5'--_ Ground-Water Elevation -_-_-_ Logged"by REH.JEE.lEE.RLJ/LEM,DAF - Graphic Log C .c .2--Q,ftI CD >CG> ~ 50 cu~Qi ~:c 0 .CI ftIQ,C E CftI0...:I G>Classification and Physical Description <;J !E z E Remarks ....Ii Ii )(S000'"lEI .E - ...., -I - """1 ! !""'I!i I I Boring NO.HD~~-Sheet __2_01 ~2,,---_ I D eJEM~~(I) SUSfTNA JOfNT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of ...2.-- Date 3/27/83 - Boring No HD83-16 (River BB) Feature U/S Cofferdam Portal Coordinates:N 3228135.0 E 747102.7 Logged by REH.JFB ,JEP ,RLJ /LEM, 90°Angle (from Horizontal)_ Bearing Date Started 2/24/83 Date Completed ----'2~/c...:2::..:7'--!/--=8:..:3~._ DAF Ground Elevation __-=-1..,..476-.:::5....::..-::::5,--_ Rock Elevation 1_4_4_6_.'-5 _ Total Depth 39.5 Ground-Water Elevation_-_-_.,..~_ RemarksSoilDescription :.----,.......,,,I·,_:'---r 1""":"y"--1,i···,:-+-',_1-..,,_{-,_.....,;-j_.i"·····-;.',' Sand~GRA\VE:u'WI'ffi'QOBBLElS'-!'to '5"~$ttptjcr~-t-~et;::g;~~Yf~~;Jif-O::"-S~~-='- rounded;:jf::ilnefltd :cqar.se.r:.). S'~~i1,~~rt ,~L·;~~t~ -,.",.....•.....;····r •..•",,;'''''''' MqiSt.I i ..... ~·l-l~·-:-.;_.__.'J~-T+-·=~T"t-j_.c.t ·+-·--f-···--···- 'ij OF ROCK19~Q FTJ .. GW 2 1 3 'E'~°Gl 'E.'tl ..c::.2 0-Gl-ZQ.::::I:..c::l!!u-«I 0Lt:l"Q,«i _C Q.~Gl>--Gl :Ec:JI111::::1 EGl -l-oci c:JI>0.0Gl>c:JIo «1-Q.'tl ~...Co l!!...1C,!!.-°en':Ec Glu !!:!.IX «1«1 oGl ...IGl e,:, en iDQ.a:: - - Boring No.HD83-Sheet -=.1__of 2 16 SUSITNA JOINT VENTURE Boring No HD83-J 6 Feature u/s Cofferdam Portal Coordinates:N 32213135.0 E 7/17102.7 Core Sizes NX GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)90° Bearing Date Started 2/24/83 Date Com pleted -:i2':-1/--z2H7y/y:8~3'l------­ Total Depth -~3'19•.-35-------- Sheet -.2..-of --2..... Date 3/27/83 Ground Elevation __---=1~4~6c::S:....!._=S~_ Rock Elevation --'1:....4'--4"-=6"--"...:.S"'-----_ Overburden Thickness 1].0' Ground·Water Elevation-==~_ Logged by REB •.TEB,TEP.RI ..T/T.EM,DAF - Graphic Log cu:>!!~.51C:c Q -;Gl .c.c.2 >-l!!...Q,0 E CamtJi::::I ::::ItJi III 00-0 ..::::I Gl Gl>'0 U g...l Classification and Physical Description ~e:z E RemarksQ.l2 :;2 u:a:Ii )(::::I !:!:!.;;)U c.:i 0 .=::i !II3 6 9 12 a:l .5 Boring No.HD83-Sheet--2~_of ? - , J - SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of 3L- Date 3T2 7 {83 Boring No HDS3-17 (River Z) Feature U/S Cofferdam Coordinates:N 322793100 E 747161.2 Logged by REH,JFB ILEM,OAF Angle (from Horizontal)__-"-9..><0_o Ground Elevation __---"'-1--'-4-><6---'-4--'0--'4 _ Bearing Rock Elevation ......1..:::l4'-'0l...llu .o...:4L..-_ Date Started 2/24/83 Total Depth 77.5 Date Completed _...2L../...2..L7.....I-"'S.....3'---Ground-Water Elevation _ Remarks 'AB··28 ;Ft.,mewed hale tiedriJil",,..., ..Rdek~1.I1;'b-1.t-··...., Ptlshing ahead c .2mcGI E 2u; .5 .weill graded'GRAVELi,.,10c~i15%coarse!san~.c iess,than 5%;sud.sat~:r;ated:, ---ot"iVe-:;--r5lincre~~-EO,-$ul5'rolih<tear;~I"rne.-·E6~ .I cbars.e,o.' ,';,_i ,I ; ,..cu-_-"i-'"·,--,-..··_}~--,..·_~-,·_··,t~·····--.--i,·"'-,-~~~r-··':""'w~~'~~.;._.~_'__.."~";_-,.---._'-:-."-_,~.~"'-t.,""_.~" G'raY.ellyl SAND,,··le~:s ,thap.5%!silt '.' GP-~S-a-cj;l'ra:t.ed-,·o:l:?-ve-gr'ey-,'fin-e:Cff"eoarsje~ subirounded tor su;bap.gula/r',fine to: a~i . GW SP SM 7 6 4 3 5 F"" SP 1 GP 2 "GH ..... I ~ c == c:i Gl 'E.'C .cO 0-GI-zQ.==.cl!!u_lIS0.:;_C Q.~GI>o 011)-GI :SCIED=EGI _l-(,)ci CI>Q.o Soil DescriptionGl>.218 Q.'C CoCGI1Il-Ec ==...GI U ~..Jr~a:lI.l.5 III III OGI ..JGI Cl (/)iDQ.a: Boring No.HD83-Sheet--,-__of_3...-- 17 ~~~~{0 SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __2_of---.l..- Date 3/27/83 Boring No HD83-17 (River Z) Feature U/S Cofferdam Coordinates:N 3227931.0 E 747161.2 Logged by REH,IFB!I,EM,DAF Angle (from Horizontal)I --'9~O::...C1__ Bearing ---:---:-~_=__---_- Date Started 2/24/83 Date Com pleted _2==-/L2==-7:...,,/L:8~3::....__ Ground Elevation __---=1.:::.4..::6~4....!.~4 _ Rock Elevation ....:=1:.:4~O~1~.!....:4:::....__ Total Depth 77 •5 Ground-Water Elevation_-_-_-_ C 3:°III 'E.'0 .c .2 1Il-Zc..==:.c:!u0"_Illac;_c c..~Ill>'0 10 "CD :E Cl11:1==EIIl -~°ci Cl>c..oGl>.~8 c..'O 1::0C,!!Ill"3:-Gla l!...I(/).5 Ec~It:III III Oal ...IGl CJtniiic..a:- - - Remarks c .2 (;j E III E 2 U; .5 Soil Description GW _'W'~J;~:'gr?:4e.d(j¥\{EljJ ~5=~O~,me.d:i:um jto I-,..::c:;:o;:::a::::.Its EtIS~~d:~~_'-t1lf~-n-·····•.n=:s~:l._·l~!1t_~~j'__" !3,"<:!.tt~~5rt.e.cJ;i4q:rr~g-r Ett.·~.._f~l1I:!Jt;q .j cQa~se; Isqh~qundedt(jjr(jun4~d;.·qcCas~dnal: ~0i5~~..1~---~Fc--c-l~---~tT--~-I ,I----r T----- 9 8 Boring No.HD83-Sheet 2 17 01-'3_ SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet_3__of_3_ Date 3/27/83 Boring No RD83-17 (River Z) FeatureD /S Cofferdam Coordinates:N ·3227931.a E 747161.2 Core Sizes -tiPl:tXA----------- 90 °Angle (from Horizontal]__---"~_ Bearing Date Started 2 /24/83 Date Completed ........2.1-1....2-1-7-1-/-""8""'3'---_ Total Depth __7L 7L£-',J.5 _ Ground Elevat ion _::.1..:..4..:::6-.:4--'0--'4=--_ Rock Elevation _-----"1c::4'-'0'-'1'--'-'04:L-_ Overburden Thickness 41:.>8"---"-'.0"'--_ Ground-Water Elevation_-_-_-_ Logged by REB,IFB/T.EM,DAF c U ~...~:2 0 Q)n osQ.C E Cos"...::I Q) Q !!:z E Remarks Ii >C ::Ia:... ti ti 0 7iICD-= Classification and Physical Description C .c .2a"; Q)", CQ) §. Graphic Log - Boring No.RD83-Sheet 3 01_-=-3_ I~ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of _2_ Date 3/27/83 Boring No HD83-18 (River AA) Feature u/s Cofferdam Coordinates:N 3227953.7 E 747110.2 Logged by RLJ,JEP ILEM Angle (from Horizontal)90 0 Ground Elevation 1465.7 Bearing Rock Elevation =-14...:...3=.=.5..:..•.:....7 _ Date Started -=2'-',/,.,,2'--'4....,/,.:::8-=3'--Total Depth 39.0 Date Completed 2/26/83 Ground-Water Elevation_-_-_-_ Remarks -=-_._~•._,..,..~-.~~.--,....-._~--.~..,-,._----.,..-, . _i.__!_ ., HardDfil1ing~ 20.5 Ftl .. ..-:':li:~'?a:~'" ,+.,..~~.?~:1ArtE;:,:~.::~J2f ~.. C ~ :! C CII E 2 '1ii -= Soil Description ;5,-12~;,-,,,,·-'"t-:-._--": 'id •..bl.ivelbrownf·iheto!t"i-,;":--.-'r--'..,,,'.",1 .,~.--",r'"','-"~ co -.lrer:e:dr--:roc-:te:..·tf1'ag11lTent:iSi1-··~·~ witih:oxi\:l:i.z'edlco'a't/:i-rig:~l :. !. ~,~-~-+-,~"-~..;,--J--..,...~..._--,--...->--L~:""-~-~"--1~'-'"7-·'~';'-'-i'-_v,-T.w.,.•_.• 2 3 1 C J °eu c·'C .c.2 0-eu-Za.~=.cl!!()_C -III eu>-0Ll):eel"0.-;lD~a.e -eu Eeu -l-e.>.CII ...a.oeu....218 a.'C c Coco!!111-Ec J ..clIo l'!!...J a:wE oeu ...Jeu e"!:!:!.1IIl'G aia.(I)a:: - 4,.... -5 ,... Boring No.HD83-Sheet 1 18 of 2 SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEV~LOPMENT Sheet~of-L Date 3/27/83 i Ground Elevation .....1 4=u6....5-0.4-7 _ Rock Elevation ..-L1-"'4,.,.3L SLo......7'--__ Overburden Thickness 25. 5 Ground·Water Elevation----=="'--_ Logged by RT..I,.TEP!I,EM,DAF Angle (from Horizontall---90 o ~_ Bearing Date Started --.<2~/'-'2;..>4~/L.<8....3J--------- Date Completed k2+/.L2../..7+I..oS....3t--_ _____Total Depth -~3,1-;9;<........OJ--------- Boring No HD83-18 Feature TIIS Cofferdam Coordinates:N 3227953.7 E 747110.2 Core Sizes NX Graphic Log c II) -'=.2 >-!.. 0:;Ol :::I :::ia Q U g~II)>"0o~.;:::I .. !:!:!...II. :i en 3 6 9 12 - 4.5~",. 50 cu::f!.Qj .2:c 0 .c a; Q,0 E C<ll 0...:::i II) Classification and Physical Description <;I !E z E Remarks a::a::)(:::I.. 0 0 Q 'liia:l .5 a-a of cor • Boring No.HUS 3-Sheet of _ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of----3.- Date 3/27/83 Boring No HD83-19 (River X)Angle (from Horizontal)9_0_o _ Feature il/S Cofferdam Bearing ...."....::~~:-::-_ Coordinates:N 3227888.3 Date Started _-----"2;..:../_2_5...:../_8_3 _ E 747264 .4 Date Completed ......2....1'-'2'""'6"'-1--'/8""-3oL--~_ Logged by JEP,RL.I,REH,.rEB Ir.EM,DAF Ground Elevation __1_4_6_3_.:-5 _ Rock Elevation ----==;;:=n--:::----- Total Depth 98 .0 Ground-Water Elevation--=-=-=-=---_ ~~."...""-,-,.~..""_..~-,,.."~ ~, ~,._....,_"."_~".J.._~"_'~.". ,-1 __'j~o~()~__,' HardDJ;"illipg @ ~_B.5.:Ji'~~_,~ ---!-----,,-,~------,----+_,,-'0"-,~,';..----,---;_--",,-'~-""---r'" I dens~,~aturated. fin~'to;medi1.im. SP sPGravel]~SANO;:']essthan ,~At$ilt~ v~:t1yde!ls.e,'gatura'ted"jvery IdaI;k,'~ ,,--g-r~-£iiIl.Q---:t~-eoar,s ~._~----'-r---- 1 1 ' , GP GW C C ~-°eu 'E.'t:I .2 .e.g GI-zQ.:::l=.e2!u «i-OJ oil)cc.-;_C Q.f:GI>o -GI :E CIa:l:::l EGl -I-o·CI>Q.o Soil Description GI RemarksCD>Cl O Q.'t:I C Co Eco!!<II-i:..Glu l!....J._0 (1).5 E C 2a::OGI ....Jeu 0!:!:!.lQ lQ iDQ.U;(I)a:: .5 .... Boring No.HD 83-Sheet ~1,,--_01 3 19 SUS1TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of_3 _ Date 3/Z7/83 Boring No HD83-19 (River X)Angle (from Horizontal),__~9..:::0:.-o _ Feature u/s Cofferdam Bearing -===----_ Coordinates:N 3227888.3 Date Started Z"'-'-'/2""--LSI-Il.l.8....3 _ E 747264.4 Date Completed _~2=.1./~2:.::6:.L/..:::8=3 _ Logged by .IEP,ELT,REB,.TEB /I.EM ,DAF Ground Elevation __---=-14=6::!..3~•.=5 _ Rock Elevation .....J.....3""8'"""3'-'.~S'____ Total Depth 98.0 ft. Ground-Water Elevation _-_-_-_ ~-°lll 'E.~0)-zQ.==~!u..5!c _Ill 0)>-011):E etQ.~-IllID=Elil -l-Ud et>Q.o Soil Descriptionet°<11-Q.~~...Co l!....._U (1).5 e c GJua::<11<11 Olll ...10)Cl (I)iijQ.a:: c .2a; C0)e oS CIl .5 Remarks - Boring NoRD83-Sheet _~2,,-of --3_ 19 SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet _L of -.3.- Date 3/27183 Boring No HD83-19 (River X) Feature u/S Cofferdam Coordinates:N 3227888 3 E 747264 4 Core Sizes me Angle (from Horizontal)__9::J.-0u-°_ Bearing Date Started -------""2'.-/1e.,,2:.-.;5H/L.(8~3;)------­ Date Completed ......2'""'!h2'-'6~.f-'/8o.3.J.--.------- Total Depth 98 •0 ft. Ground Elevation J.L.c4!::LU6...J3e..-....5L.-_ Rock Elevation -----J.]....,;3u;8:L.3J.....5J----- Overburden Thickness 69.5 Ground-Water Elevation~~~_ Logged by .TEP,RI"I,REH,JFB /LEM.DAF .Sit-arte.a Gori1:J.gi;S·Z...:O .Core"'lOl§sprobably a:t:~tofP:-of'~ttif[;...... '€O''r''e'''b-r e'aks'eas±ly--'• ~andlang!. ~~..._.:~~t7~~=~~~-Atrer'ear1ri:iYrite~;::];zn:E~tIin_'1:gli:F: i+hr0Wnl~h;Vlht,ir,ned.Sylni.imas~live,·. F~~'~4~·..~~t...~:..:~~:~cJ~mlli;l£ed1:ti£-.KaoJ ..inLP.se4li~,~p.li&....f~.._...~ F eaft:Frif§ldspar~1Jgi~t:?,lso1l1el ...talc, ..{staibft,rI,~lt:..~ji.n!:•I,'::..~._...:~.:.-+···.·:;;::.:=Tq:+2 ,§~e,a·rie;~:~9gt:·t9,sl,....f~c t T.~x PF iZi~5 §l i btecci?min~'OU·mQ$tlyrQ(.2;"O ..pi ".r ...!-t:·~"''--'Tr-Th15Ie-~o''lidrwearq:f:O:i~l:rongJ='';- '1 .;a.Jtl?Oliles of~igp.lVI &mj)dlYal t .·..~~~,....~t--'l ......~~1.Ed:?ones.lUa¥-¥-y-t:..ot:e.'8U r fc I rough &~rreg~diie!towshg of· .'··'c);ay·......•...'...•.....".'.' ..~..;.~~.'.-9S-£l.t::red...Dio..r.i..t.es.l ig.ht.lY'-H...•- ..!.gray wrpartly kaotinize(LpSeild~,inhr- phi$Q~pl~giiPc+ase.Sl':"mod fract:~ .......,....~1;~~...-max.;..2.·5~tmi'tl:'"+~hl"1D:ostl 1).•-6..&78--;.... ar ,s rong. Graphic Log cu:>e ....2C:c a <\I <al!!.c.c .2 >-<II Q,c E 'E0...::10 '"0'C.m 0 ::I -0 ~::I <II <II>'0 ti ~..J Classification and Physical Description <;l e:z E Remarks"'"o~::I Ii Ii ::I;:...II.)(...!!:!..:J iii d d 0 "iii3 6 9 12 I:D .5 r - - Boring No.HD 83-Sheet_3_of 3," SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _2_ Date 3/27/83 Boring No HD83-20 (River W) Feature u/s Cofferdam Coordinates:N 3227868.8 E 747316.0 Logged by JEP,lU.J,BER,JFB/LEM Angle (from Horizontal)90° Bearing Date Started 2/27/83 Date Completed ---,2"-1/~2::.>8<...L/--,,8,-,,3,----_ Ground Elevation _---"1"-4-'...:6"'-4-"-!-.9"'--_ Rock Elevation __--=1.:3..=8..=8'-'.'-'4'--_ Total Depth 76.5 ft. Ground-Water Elevation.=-==---_ ~::i:~~A:~i.:i}~:n . Remarks K;=7.4E-03 ..Hard Dr;iiiing. 3~-37Ft. c .2 «i 'E QI E 2 iii .E Soil Description SP GW GW GW 5 6 2 7 4 3 1 OCl) ZQ. QI>--~ Q.'t:Icc ftJftJ II) QI-_ftJ Q.C: CQI ftJ- II).E C .c .2a-; QI> CQI §. .... - Boring No.HD83-Sheet_1__of __2_ 20 SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet Z of 2 Date 3T27/~ Boring No HD-93-20 (River W)Angle (from Horizontal)__~9,-,0,,-o _ Feature U IS Cofferdam Bearing Coordinates:N 3227868.8 Date Started _----"'zcLl...,Z'-'.7..L1-"8'-"3<--_ E 74731 6.0 Date Completed ....z"-I...,2""8..1-1""8""'3 _ logged by lEE t RT,T t REB,lEB /J.EM Ground Elevation 1464.9 Rock Elevation ~::-=----=-_ Total Depth 76 •5 Ground-Water Elevation _-_-_-_ - - - 'GRAVEE;COBBLES'&BOULDERS, :WetJgiey ;suqroullcled;':Ii irie.'" "tG-aoar-se~..-·'"-~,j-'--'-:l-~~-~t_"·--T--c·~·:'---·· 8 9 GW , "",j GW 10 11 GM c: oQl 'E.,;j .2 ~;:-;;0-QI-zo.~=.ct!!u_<0 0 10 E_c a.e:QI>--Ql :C Clm~EQl -~0c:i CI>0.0 Soil Description GI RemarksClO<0-o.,;j 31:...Co ~...l E._0 (1)=E c Qlu 2a:<0<0 OQl ...lGl Cl (I)iija.a:Ui .E 100 Boring No.HD83-Sheet---L2__of 2 20 ~ilM~(6) SUSITNA JOINT VENTURE SOIL BORING LOG Sheet _1_of _3_ Date 3/27/83 Ft. Boring No HD83-21 (River V)Angle (from Horizontal)_---,-----"-9-""0_o _ Feature u/s Cofferdam Bearing Coordinates:N 3227846.7 Date Started --'2...../'--'2....,8"--'1'--'8"'3"'--_ E 747373 • 1 Date Completed _~3'-'/---'0"-"1'_L/--"8'-"3'-,._ Logged by REH,JFB.RLJ ,.TEP ,lIlMB/LEM,DAF Ground Elevation _--.:1~4.;-6=-7,:--,--'=-7 _ Rock Elevation 1_4_0_1_._7 _ Total Depth 86 .5 Ground-Water Elevation _ Remarks K=2'.lE-Q2 K:;::1.2E;"'02 Bf::~k~:}:;;:JfiJ;(;{{;fZJ ~5~0-,",-,,:,_.I:1AM.,..c.:L_,. c ~ III C III E 2 Ui ..5 GP GW GW GW GM SP 7 6 2 5 8 3 "9 10 ~ c j °Gl C.'C ..e.2 o-eD-Zo.:::1=..ee u_C _Ill Gl>-0.":cO)a.';c.>-Gl113:::1 elii -I-°ci Cl>0.0 Soil DescriptionGl>,2l8 o.'C Coc~Ill-Ec j ..Glu ~...I ~t:r (/)..5 ~Ill oGl ...IGl "iDo.t:r SM 1 ..... - .- - - Boring NoHDB3-Sheet -----..11__ot ----3 _ {lfl ~~(f) SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 2 of 3---- Date 3/27/83 Boring No HD83-21 (River V)Angle (from Horizontal)90° Feature u/s Cofferdam Bearing Coordinates:N 3227846.7 Date Started _----i.2'o.J.I--'2<J,8ul:..!.81...3L-_ E 747373 •1 Date Completed ~3.I..L.:1Q!L1L /u8,L,3L-_ logged by REB,JFB,El,J,TEp,WMB/T,EM,DAF Ground Elevation =:14~6.!...7..!.•.!...7 _ Rock Elevation ----"'-1::!4.!,!0""1..........!.7 _ Total Depth 86.5 Ground-Water Elevation-=-:..:-:..:-=--_ - - - - GP13 100 C :i:om C."tI .c.2 m-ZOo :==.cl!!()0-_lIS a..~_C 0.'"Gl>O OlD -G,l :E CIlll:l:=E~-l-Oci CIl,.,0.0 Soil Description RemarksGl>CIl O Q."tI CoQ,,!._0 «1-Ec ~...Gl()e..l !!!.a:en':«lea OGl ..IG,l ClenjiiQ.a: 11 ~ 12 SP Boring No.HD 83-Sheet 2 of_3-- SUSITNA JOINT VENTURE Boring No HD83-21 Feature u/S Cofferdam Coordinates:N 3227846.7 E 747373.1 Core Sizes _NX.........._ GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontaj)'__~9Cl..OL..°_ Bearing -'- Date Started 2it...1-1it..2o.8.J../.a8..;l3~-__ Date Com pleted --..;l3'-J../-I.<OhLl,...J/...(;8l.;3)..---- Total Depth 86 5 Sheet --..:L-of--..:L- Date 3/27/83 Ground Elevation J 467 .7 Rock Elevation 1401 .7 Overburden Thickness _(u-,7~""O _ Ground-Water Elevatiofl""c:c-=--=--_ Logged by REH,JFB ,REJ ,JEP,WMB/LEM Graphic Log ~CD=:;Cl-0tig...l 2 u:en 3 6 9 12 .- -- - !""" - ,,$5_75 0 !- ~ _9..0, f""" 100 cu~G>.2:E 0 -;.ca.C E Cl!0 =CDClassificationandPhysicalDescriptionq~z E Remarks Ii a:)(g <3 <3 0 rtIa::I .E Barino No_Rn81-Sheet 'i af 3 1:- SOIL BORING LOG WATANA DEVELOPMENT Sheet_1_of ~ Date 3/27/83 Boring No HD83-22 (River U)Angle (from Horizontal)90°Ground Elevation 1467.6 Feature U/S Cofferdam Bearing Rock Elevation 1380.6 Coordinates:N 3227828.8 Date Started 3/01/83 Total Depth 107.3 E 747416.2 Date Completed ----'3"-"/LO"'-1"'-L../><.8=<.3 Ground-Water Elevation_-_-_-_ Logged by WMB,REH,NBH,JEP/LEM,DAF Remarks K=1.1E-02 c .2 fti 'EGI E 2 '0.: t 9 6 7 2 8 4 1 5 3 C 3:°Gl c·"C .cO 0-GI-Za.:::l::s::.l!!u_CISQ.~_C a.e GI>-oil)-CD :COl1l:I:::l E GI -I-(,J.01>a.o Soil DescriptionGI>.218 a."C 0 CoOJ!as-Ec 3:--Glu ~..1 ~!!:!.a:en':OCD ..IG1 0asasma.en a: Boring No.HD83-Sheet 1 of __4 __ 22 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of~ Date 3/27/83 Boring No HD83-22 (River U)Angle (from Horizontal)90 0 Ground Elevation __=-14...:...;:.6..:-7~.-.:::6 _ Feature U I S Cofferdam Bearing -====-_____Rock Elevation __~1:..=3:..:8:..,:0~.~6e_______,__-- Coordinates:N 3227828.8 Date Started __--=3e...!/~1~/--=8:..:3e...._Total Depth 107.3 Ft. E 747416.2 Date Completed 3/1/83 Ground-Water Elevation~-~-~-=---_ Logged by WMB ,REH.NBH,JEP ILEM.DAF - ... .... I ..... GW GP GM I-:--'--c---+-",-,"-+C--,-~,"C-~_.-.._-+---.-i--.----•.-__----I----+--'---'"-j 17 15 16 13 14 11 12 C ~0Ql E-'t:l ~CD-za,::I:::.c!l,)m0-_Ill C_C a.>CD>-°Ul -Gl :C:OIm=EGi:-....°ci 0»0.0 Soil Description Gl Remarks.218 m-o.'t:l ~..Co ~...I E lJ)':Ec all,)=II:OGl ...ICl)CJ .:::11I11I mo.lJ)II:CI) .5 10 100 Boring No.HD83-Sheet --,2",-------.:...of 4-__ 22 GEOLOGIC LOG WATANA DEVELOPMENT Sheet -.J.~~of ~_ Date 3/27/83 SUSJTNA JOINT VENTURE 04.~' Boring No HD83-22 Feature U/S Cofferdam Coordinates:N ---.3j.,2,6.,20!071-8~2~8••~8---- E 747416,2 Core Sizes __-"NX"""'--_ Angle (from Horizontal)__~9~O:.-o____Ground Elevation __=-1--=4--=6--=7--=.--=6'---_ Bearing ~_____Rock Elevation __---=1:...:3:..::8:...:0::....:...-.6=--_ Date Started ~_3""-L1-"'-1_L1-"8!..",3'--Overburden Thickness Date Completed ~31-/.l.J-I-/.c8L..:3L-______Ground-Water Elevation-==_ Total Depth J 07 3 ft Logged by WMB,REH,NBH,JEP/LEM. AF .;,......,."; :Me.cha.:nical Brkg -.SQme+g:tina:iD.~.--.. N-..... 80 75 F"'"45°/ 90°J ~:95 60°( 50° t!!~45° 100 .-. - Graphic Log cu~Qj ~C :E 0 l!!.c as.c .2 >-!Q,c E CQ.m 0 ~~o as 00ug.3 ..~Q) Q»'0 Classification and Physical Description q E!:z E Remarksco!!.;2 ..Ii Ii l(.5!!:!.iii I&. ::i ti ti 0 en 3 6 9 12 ll:I .= ~ - .- -I - Boring No.HD8 3-Sheet 3 of _4__ SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT SheeL 4.-0f_L Date 3/27/83 ( I Boring No HD83-22 Angle (from Horizontal)....:9_0_o _ Feature U /S Cofferdam Bearing Coordinates:N 3227828.8 Date Started __------"3...:../,...::1...:../,..-8....:3 _ E 747416.2 Date Completed _--=3:.-':/--=1'-':/--=8'-::3'------_ Core Sizes --"N_X Total Depth 1 07 .3 Ground Elevation _~1~4::!:..6",-7L.!...'"'6 _ Rock Elevation __----"1'-"3'-"8"-'0~.6><--_ Overburden Thickness 84.0 Ground-Water Elevation __~_ Logged by WMB,BEH,NBH,IEP/LEM,DAF Graphic Log cu':!e.:il oS!C :c o .-;e .c.c .2 >-(II c-o E "ECl..-=g'l'!!00.';0 -=:::J (II (II >0 U g...l Classification and Physical Description q ~z E Remarks -oo!!:::J-=....Ii a:)(2!t!.(j)II.0 u;::::i 3 6 9 12 ti <,;al .E .... ,~ Borina No._HD83-Sheet 4 l)f 4 SOIL BORING LOG WATANA DEVELOPMENT -"--' Sheet....-L..-of --3 _ Date 3/27/83 ",.. Boring No HD83-23 (River T)Angle (from Horizontal)_~9",-0",-o Ground Elevation __--'1=-4.:.-6=.;8~.0=--_ Feature U/S Cofferdam Bearing Rock Elevation .::;.1.::;.3.::;.9..:..7 _ Coordinates:N 3227810.9 Date Started 3/1183 Total Depth 87.0 E 747469.8 Date Completed 3/2/83 Ground·WaterElevation-=-=-=-=---_ Logged by NBH,JEP ,REH,WMB/LEM,DAF c ~ci Gl c·"CI ~.2 o-lD-Zo.:1=~l!!u_C _lU Gl>-o It'):Eele.G;0.>-IDlD:I Em -~()c:i el>0.0 Soil DescriptionGl>.218 lU-0."CI ~..Co l!!..1.-c..!CI).E Ec CDu I !::!:!.a::lUlU 011I ..lID ClCI)iDa.a:: ~I GW GM GW GM GW SP SM c :8 lU C CIl E 2 Ui .E Remarks Boring No.HD83-Sheet---=-1__of 3- SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _2_of-3..- Date 3/27/83 Boring No HD83-23 (Riyer T)Angle (from Horizontal)-,-._~9~O>l..°Ground Elevatjon __--"1=--'4c.::6~8'_'.'__'O"___ Feature U/S Cofferdam Bearing --==::.,..-_Rock Elevation ----Jlh3).;9~7'==_--,----- Coordinates:N 3227810.9 Date Started __=.3.!..,/-=.1.!..,/=.8=.3_.Total Depth 87 •a E 747469.8 Date Completed 3/2/83 Ground-Water Elevation __~_ Logged by NEB)IEP)R EH )!tilMB II ,EM)DAF '"'" -R~fusal at 72",0 BlitPu~hes '-g;raxre1r asiQe.~·- c ~ «I C ~Remarks 2 Ui .E SM13 12 11 c ~°CII c·'0 .cO 0-GI-Za.::I::.c~u_«I OU)"5.:;_C o.e;GI>--GI :EO)ID::I EGi -~(J.0»0.0 Soil DescriptionGI>0)0 o.-c Cl Co«1-~...~...Ico!!._0 II).E E C CIIua:oGi ...IGi Cl!:!:!.«ICII iii a.II)a: 10 GW-GM Boring No.HD83-Sheet 2 .....,of 3 SUSfTNA JOfNT VENTURE Boring No liDS3 23 Feature U/S Cofferdam Coordinates:N 3227810.9 E }/,7469.8 Core Sizes l\i"X GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)_---'9"-'OLo _ Bearing ---=-=-_ Date Started -----.,;31-/-/....1'...J1c-<.8....3J.--- Date Com pIeted _--,;3'-JI,-<Z:.../u8::t.3;l...- Total Depth _ Sh eet ---3.-of -----3.- Date 3{27{83 Ground Elevation _-=1c:l4~6~8!...!0~0~_ Rock Elevation _-----J.1_3<.;;9u7'---_ Overburden Thickness _--'-7--""1'-'0.....,0"---_ Ground-Water Elevatiol1--==-_ Logged by NBH.JEP ,R$H,WMB /LEM.DAF r Graphic Log c u ~Q;.2C:c 0 -:;!.c..c .S!>-lD a.0 E C0.:;CI :;~C1 ~00u-0 Classification and Physical Description :::l lD lD>'0 g.."<;J !:!:z E Remarks OlD ;:~...a::Ii .s~.;LL.)( ~In <3 <3 0 <I) 3 6 9 12 I:D -= ..... .- _90 100 Boring No.HD83-Sheet--.3_of~3,--_ - SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _3_ Date 3/27/83 Boring No liD83-24 (River I) Feature D/S Cofferdam Coordinates:N 3226748.3 E 742979.2 Logged by NBH.JEP ILEM,DAF 90 0Angle(from HorizontaJ)__--=:....::......_ Bearing Date Started 3/2/83 Date Completed -----:3::.1/'--'2=..</....::8::.::3:.....-_ Ground Elevation 1453.8 Rock Elevation 1409.8 Total Depth 57 • 0 _ Ground-Water Elevation _-_-_-_ Remarks HAM,Ox'-+-· Refusal @ 27Ft. '!S1:'a:rtefr-Ooring- c .2-:; 'C G> S .5 (/).= Soil Description GW GP GM r-'~~-~-,-""'-+-"--c,-,+---~-+-,_--,-!.-"-..,.....~...c.....-_+-~----l 'tI .cl!!-CD1:11>Co IDI.! ....I CD II: 'C.:::I: Oil) 0c::i ~... OllJ iDQ. 2 lA °CDZQ. lIJ>O-~ Q.'tIEc l'lI<IIen 1 50 C .c .2a.,; CD> QID ~ - Boring No.liD83-Sheet 1 24 of 3 SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet_2_of _3_ Date 3/27/83 - Boring No HD83-24 Feature D IS Cofferdam Coordinates:N 3226748.3 E 742979 2 Core Sizes NX Angle (from Horizontal)_----L90"'-0 _ Bearing ---==~_ Date Started 3~/1__2"--1--/!.l.8...l3 _ Date Completed __---1.3./-/42-1-1.....8'-'3'------_ Total Depth ..L57L..o....J./.O _ Ground Elevation 1453.8 Rock Elevation 1409.8 Overburden Thickness --38 • 5 --- Ground-Water Elevation_-_-_-_ Logged by MBH.JEF/LEM,PAP - 'rEi:-Tbp OFjRO.cK144,~olFt....~.-".'.. .44-47 Diorite as abovewlspm~ -k,:.::fiUdapar....1:....---.-_..----_._.. .Closely intensely fracto O.OtH 0 •..5'sl-modt weath hard,rodt strg.50 60°/ ~.Q 45°/ 90°5 Graphic Log l: l.l ':!!.Qi .g C l!!:c c iii..c.c.5!>-l!!a.c E 'E'C.ca OJ ::I ::1m III 00u-0 Classification and Physical Description ...:::I CDCD,.'0 :i..J <;'e z E Remarkso.!!-.5 ::I ..a.:ri.2!!!...u.)( ~U)0 d 0 iii3 6 9 12 m .E i ! 300 .,--tl-.....-········_-Iirt>u.E·::-s.F.·fra.ctrd.•..max,Ze ..O' 10°.,.~.....ma.ll o,,-l~mostly'p ..5-2:.p:r,.~reSh: 1.351 ...1.··'·'~=I_J.l\!ny;rg:atlt~J_~9J.I~iilillt:X~_~tJ.a~.rr~L.Qn=. 30°.....jts'~~t91§<L§trg;r fr~sh.f..ups-t;a;i.ned 15°-~cepti()n~Jl=s~.Somef;aCOal' 1-"..,••.j .---t-:==T;i.IITiigs.a 5:;----·---,---0-------+----·-4-'" Boring No.HD83-Sheet --=2__of~_ SUS/TNA JOINT VENTURE Boring No HD83-24 Feature D/S Cofferdam Coordinates:N ---:3;}-;2&.2t-'6a-7+-<4q.8lh-.~3--- E _--I-C74.....2.:...;9~7'-;l9c...•.L.2 _ Core Sizes -"'NX'=-~------ GEOLOGIC LOG WATANA DEVELOPMENT 90 0 Angle (from Horizontal}__---=--=--_ Bearing Date Started __""-3-'-1...2.....1-"'8""'3'----_ Date Completed -"'-3.1-/"'-2--./8"'-3"'-----_ Total Depth 57 .0 Sh eet -----3-of -----3- Date 3/27/83 Ground Elevation 1_4-c5--=3~._8 _ Rock Elevation VI 09.6 Overburden Thickness 38.5 Ground-Water Elevation_-_-_-_ Logged by NBH.JEP /I.EM,DAF - ..., ..... ..... Graphic Log c lJ ~...2C:E 0 III -;III .c..c .2 >-!..a.0 E C'0.-;CI ==8'e!00 =III GI >0 U ~...I Classification and Physical Description <;I e:z E Remarks oo!!::=..a::a::)(::I !:!:!...u... ~in <3 <3 0 Ui36912III-= N CT\-oo..-. SOIL BORING LOG WATANA DEVELOPMENT Sheet_1_of_3_ Date 3/27/83 SUSITNA JOINT VENTURE Remarks .5!i~f'...HAM,er 1 ~.~_..",,~..~--,-,~,--,~.-..,~-,.;",.~~_.,', Drive bit plug- ""ged,ZO·~:·Ft."bf sampleic.ollected £p.rit4.(..1.).. c .2<; 'E0) E 2 Ui .5 ft.Bl:OWby,di$char e hose ,plugged; Ground Elevation 1454.4 Rock Elevation 1379.4 Total Depth 95 .9 Ft. Ground-Water Elevation_-_-_-_ j :;- ~--".~+",..-,~-,.:-~>-.,..~.~,....-.•.. Formation proPl'iblyi a lbbse sl'ind, satUrated,verydarkgrj;y . •~."._.-,_,_.,."_",q,,.~_.~._._.,~~.,,".~~~.•...•_._..~J-,"~,_,._.•_...m-.__t·..._.'"w,_",,_,~,,__._.,.",,_._ SW GW 2 4 1 5 3 C i °Gl C.-a .e.2 0-Gl-ZOo :::l::.el!!u_ClIam_C Q.t:Gl>-oll)-Gl :E",l:Q:::l EGl -...0c:i "'>0.0 Soil DescriptionGl>.!?8 Q.-a Coc~ClI-Ec i ..Glu ~...1 !:!:!.a:0=ClIClI o CIl ...10)Cl If)iiiQ.a: Boring No HD83-25 Angle (from Horizontal)__----=-9..::.0_o _ Feature Dis Cofferdam Bearing Coordinates:N 3226970.9 Date Started __---"'3CLIc"'3CLI,-"'8""3'-----'C'-"'D:..L)_ E 743087.1 Date Completed _--=3'--'.1--=3CL.1-=-8-=3----->.;CN::.:..)<--__ Logged by WMB,REH,NBH,TEp/T.EM,DAF - ..... - Boring No.HD83-Sheet 1 25 oL_3__ II SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __2_of ~ Date 3/27/83 Boring No HD83-25 Angle (from HorizontaJ)_~9!...>0!....o Ground Elevation 1454.4 Feature D/S Cofferdam Bearing Rock Elevation 1379.4 Coordinates:N 3226970.9 DateStarted __~3!..L/~3!..L/~8!...3L-..l.e,...l.D4)'--__Total Depth 95.9 ft. E 743087.1 Date Completed 3/3/83 eN)Ground-Water Elevation_-_-_-_ Logged by WMB,REB,NEB,,IEPjJ ,'EM ,DAF c ~°III 'E."tI ..c::.2 0-1Il-ZOo :::l:::..c::l!!u_aI--_c Ooe:CD>'0."-CD :e Clo.t'll l:D:::l CCD -....Ud CI>0.0 Soil DescriptionCD>ClIO t'll-o."tI ~...Co f!....o~._U en.5 Ec CDu !!!.II:alt'll OCD ....CD Clenaio.II: SW 6 c .2 fti'E G.> E 2 U; .5 Remarks ..... - - - "" Boring NoRD83-Sheet -----'2=----_of _3_ r _ SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA bEVELOPMENT Sheet _3._of ..3.-- Date 3/27/83 Boring No HD83-25 Feature DiS Cofferdam Coordinates:N 3226970.9 E 743087.1 Core Sizes ---..LNX:>IA-_ Angle (from Horizontal)90° Bearing ~~~_ Date Started 3/3/83(D) Date Completed 3/3/83 (N) Total Depth 95.9 ft G round Elevation __-'1'-"4:<..5.....,4'"--"-'.4,,--_~ Rock Elevation 1....3.....7'-9-'--"-'.41-_ Overburden Thickness 67 •0 Ground-Water Elevation~_ Logged by WMB,REH,NBH,JEP/LEM, ,, •...._,,_·,0__·+·,_.··.W",.~=..',.,.....,.+~~,'~.~·.,,"...~~~_~.('-...'''_,~; ,~ow frad~sdue .·mac.1f·o:rKg~···· Graphic Log c l.l ~Gi .2C:c Q ;; .c .2 >-G)G)Q.C .t:l......E c:0.-;Cl :I ~ga 10 00...:I G) G»'0 U :;:...1 Classification and Physical Description q !!:z E RemarksCG).;::I ...a:Ii :I ![...LL.)(... :::i iii c..i c..i 0 u; 3 6 9 12 II).= r 90 !""'"45 60 45 45 45 45 .- 100 Rnrinn Nn.ltnA ':l,_Shl'!..t ':l,nf ':l, SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of _3_ Date 3/27/83 Boring No HD83-26 (River M) Feature D/S Cofferdam Coordinates:N 3226895.5 E 743049.9 Logged by TEP ,NBH !LEM,OAF Angle (from Horizontal)__--'9=-0=..-o Ground Elevation __-=1=-:4-=5::...:3:....=-:.8::-_ Bearing Rock Elevation ;;;;.1.;;..3.;;..7;;;;.2..,:.._8 _ Date Started 3/4/83 (N)Total Depth 96.OFt. Date Completed -'3~/L4"'"'/L.:8"'"'3"'----______Ground-Water Elevation-=-=-=..-_ Remarks , .IJ<a.rdDrilling.J 32.5 Ft. ..EasyPr illing...@. 40.5-42.5 Ft. c .S!-; 'E eD E 2 'lii .E Soil Description GP GM t-'-..~--'-..i..•..•-••~•.,.~.c~-.~r-..--•..•..L ..•.•..,..._.,..••.•.._.•.....•.••...•••__,••. GW GM "C:I .cl!!-CDCI>Co eDu ....eDa:: 'E.~=0."(,).o ~MOCDiiie. 5 8 2 1 OeDZe. CD>--I- c."C:IEc 1lI1l1 UJ ~­!1c lD~ .218a:: C .c.2c:; CD> QeD ~ 3- 4 GP GM 6 .- 7 SP..... 8M Boring No.HD83-Sheet _I=--_of --.1.._ 26 MaUWA~I!~! sus/rNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT \Sheet_2_of------3- Date 3/27/83 Boring No HD83-26 (River M) Feature Dis Cofferdam Coordinates:N .c=3!.!;2:..f2:..l:.6!.!,!8:..29:.d.5'-o.•.d.5 _ E 743049.9 Logged by JEP,NBR!LEM,DAF Angle (from Horizontal)9""O"'--o _ Bearing -==:....-_ Date Started 3/4/83 Date Completed _3J..J/~4:L./w8.l.3.L.__ Ground Elevation 1 453 .8 Rock Elevation 1372.8 Total Depth 96.0 it. Ground·Water Elevation_-_=_=_- c:~cia»'E.'aGI-ZQ.:::I:.cl!!f,).c .2 0-_01 'Q.ca _I:Q.e:111>-010 -Gl :2 01a:I:::I Eo»-l-Ud 01>0.0 Soil Description Remarks0»>~8 0.-0 Coco!01-Ec 3:...Glf,)l!..I a:en.5 oGJ ...IQI "~01 01 jiiQ.II:0 GM GC - -J I Boring No.HD83-Sheet 2 26 of 3 - - SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet _3__of _3__ Date 3/27/83 Boring No HD83-26 (River M)Angle (from Horizontalj,_.;z9l.l0-o--_ Feature Dis Cofferdam Bearing ---=~=-__~_ Coordinates:N 3226895.5 Date Started __3).,/w4~!(..J8:l..3.:>-_ E 743049 9 Date Completed _3.;J..,,...,/4~!1-'8.>-.3.J--_ Core Sizes -J1;JN,iIXlr----------Total Depth 96.a ft , Ground Elevation _---'1"-.:4=>-,5"-'3"'--'-'.8"'----_ Rock Elevation 1372.8 Overburden Thickness -,7,-"-,-).o-!\,",,-I _ Ground-Water Elevation_-_-_-_ Logged by JEP.NBH/LEM.DAF B.,a ·C,":.t. 1--,-"-"'---",,,I--l.~k-~~>-~..,:,,",~~L-.-L.J---4_~,~..-'"'~-~._--i--+_''-_,_..c"j==_;-~....__.. 1-_+-~...,..."'*-_--j..-................_1\aR..iOF~QCK.81.'O ojoo'__.........__--- ,,'8:1'~84.]':ilor:iltegray,:-nj.edXYln • ;'i~':ErEfsK""Wme~TmIiiefar~~t:Lon,aIon~I~" •""','""",1 jts~"",J:1ddtf~act;.;;1.'.3"'Q;;~'·;;hardJ,,.;':'~=S~rT)~~1L~fL~~,S~,,~~=~.~ti:~!!~·§T~!n~g~~m """,.841.,7-:96 .,QAltered ,D:1Qr:JL1;4e ,1ltLgray ~;t:::fQ:wIi.j[e-e;IIiea~~'"g r aTn~~a.",Vatla:1tt}! 'alEd ,pattiaJlIytdtot~~IYElq:ong ....a.t.t+.hal:4_.t!L."aoLt.,cmd:Ltlfiahl.e~~xaT:·~" spect:i1lEtly.J~4~Z...,a6Deeply alter~, 86;;;;93 s]a,ltd.:9:3-+96 Altered.,. .--+_.L···~·r-··crr~·se!y~moi:IEt'rfatte:--·Max·rO::lr·miIi :O.J ..'.J:1QstlyO.3-;O.7 uns4Cl:jned , ~_.;,.=.cJ.ay;:e.y.~in:J:ii.ghl.y ..:~;.t..e.r.ed"in1ler.v:a~s .•. Graphic Log c.....C CJ ~...~::c "II> .c.2 >-j!!l!!a.0 .a '"ac;C):::I =g''"0 E C 0 U Classification and Physical Description ...:::I II> II>>'0 g..,J C!'e:z e Remarks 011>::2 ...r:i r:i 2~u.)( I"'"~iii <3 <3 0 Ui3 6 9 12 a::I .5 .... ..... ..... I~ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of -3- Date --sT27/83 Logged by ..... Boring No HD83-27 (River K)Angle (from Horizontal)__9_0_o Ground Elevation __----714-=--=-5-=-3...:.0-::7 _ Feature D/S 0 Cofferdam Bearing Rock Elevation 1_3_8_3_0'-..7 _ Coordinates:N 322682402 Date Started 3/3/83 Total Depth 9805 E 74300709 Date Completed 3/4/83 Ground-Water Elevation_-_-_-_ TEP,NBH,REH,WMB/LEM,DAF c ~-oeD C.-c ..c .51 CII-Zc.::;,::..cl!!u_C _ftI !!l.~OU):EQ)a,;c.~-CIICD::;'(j.Q» CII >.5!l8 ECII c.-c c Co c.o Soil Descriptiono!!l.ftI-;=...~...I(1)..5 Ec CIIu-~a:ftIftI OCII ...ICII CJ II)DiC.a: - 1 2 3 4 5 6 7 8 GW GP GM GP GM GP r:: .2 «i CCII E 2 '0 ..5 Boring NO.HD~1 Remarks Sheet ~l!.--of -----3 _ ~(I) SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of_3_ Date 3/27/83 Boring No HD83-27 (River K)Angle (from Horizontal)90° Feature D/S Coffernian Bearing ---=~..-:::--.--::-",...._----- Coordinates:N 3226824.2 Date Started 3/3/83 E 743007.9 Date Completed __3=....c..-/4..;..:..../8::...:3=---_ Logged by .TEE,NEB ,REB,WMB hEM,DAF G rou nd EI evat i on _---=-14---=-5=-3...:..-=-7 _ Rock Elevation __-=1-=3-=8-=3:....:.:....:7,....-_ Total Depth 98.5 Ground-Water Elevation...:-=.:-=.:-=--_ _I c ~«l C ~Remarks 2;; -= GW GM r"GRAv,RLjntcb~t5trfjlOno-=4~Et~~Dl-grt~:r=::J GP GM I--,-~~-i-,--r-~+.L_--.L-:-.~--------.;..------:------,--4---.;.-,--+-----.----1 10 12 11 C 3 0Ql E·-g ..c .2 0-al-ZOo ~=..cl!!u_C _«I QI>'0",:COl'Q:;l:Q~Q.i::-CD ECD -l-Ud CI>0.0 Soil Descriptional>Cl O «1-Q.-g 3 ..Co ~...lOO!!._U (/).5 E c Gil.) !!!.a:«l«l o CD ...lCD CJ UJ aiQ.a: 9 GP RD8 3-Sheet --=2=--_of 3 ?7 SUS/TNA JO/NT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet -----3-of ----3- Date 3/27/83 62.0 Boring No HD83-27 (River K) Feature Dis Cofferdam Coordinates:N 3226824.2 E 743007.9 Core Sizes NX Angle (from Horlzontall __L9-"'0'---o _ Bearing Date Started 3/3/83 Date Com pleted .-./.3-#-1.",4-#-1.....8'-'3'-----_ Total Depth _--.;9;zJ8~.L5 _ G rou nd Elevati on __--'1"-4-'-5=<.3"'-'-0.:....7 _ Rock Elevation -"'1~3"'8'_""'3'--'.L17'___ Overburden Thickness Ground-Water Elevation~_~_ Logged by JEP,NBH.REH,WMB/LEM,DAF ToD •.=98.5 Ft. H-~2 Andesite )me~:g,l:1e}f,lrine ." .§:tt::~~qc,1=~Jtg~g,=~~ :...;.•,;7'1 ....:116 1 :xpd-O;:6'l m:tln<O.'l:,j· f"CalC;03.1 L.l~':.•.......r,f ..1'•..•..•.'f+rt--:.CO·~·T·j.~)C11~=O ...~~_CJtds.a<frac~.~­,..a 3 "812"....•····b·······~a-·2.·0 ..,,.:h····'d"& .f L .j ..j '.'.0;~o~p,c:s:.L"'"..4-~'Ia.:tj.1 • I"ca'C03.r strqng ,,:flre-sh ;&uns\b::i;iii'daldng -:-~JL-~~f~~~~~~Jl- .......:....•......:..;II .'I ".", '...8,2-94 .A:LqeredJDior:iJte,~hil te Ito "-<--'-~--~i'tf;:<g~~;:'-~o.t:t:P;::P,'El~eu;q(:)ntcrI"J:J,tfS "'·1·,.....,.•La~:tl8'·l:1fj~d$par,.taJj~&.$()me~t~ ;:'~:L,:L_._L:'\laX:;IB>?'y:..-alt ere4•ddtall]y:---tii-~_..; ..pa.x:tiJJYfI1ia~~~EL .c~ayey;to -licit:d ;&sqrong";ieSfR.;;8I2";9,3f-·~otaJlly c-'--·=TraTt.~r[:---9!l"';91lpr7part1a;r:aJf~liFJ-:"-'L< I IIntense-:c:U0sie ;fr~_c.tq):Ina~Ipc.q.5 _.....1•....'......--·-i-nrin--.c!B~-'0mostq:~y·r<tt2:...,e-;.:r,-~t:p~h ;j:t'2;~urfaC_l;$lJ\~sta:ilned •.I;1; ~'-,-<·L-'--t~~~=~~'5;··TIiorrid~-;.-~gl:eY';;:-~e<t-·}t~!'fi .''felspar~xnbJlende)IBia;mod.· -----.-£r:a.qtma..~:L.S-1';m~tl4.u..l;-'-·mostJi-¥-­ 0.5...'0.7",·hard,st:tlong;.frtisH ....__:tl!l'_s_~_a.in~9L_:S;~_~~"S;:UI'!~~~!L_9L __i __.. .chloron:'tsi Graphic Log cu~:D .S!C :E 0 0;;l!!..Q ~~.S!>-l!!Co c E C'E.';01 :::I .3g'lQ a0..:::I ell CD>'0 ti ~....l Classification and Physical Description <.?!:E z E Remarksc,!!oS :::I a:a:>C :::I..U...!:!:!.::i Ui c,j c,j 0 1ii3 6 9 12 III .5 r- - ..... ..... ---' ~fffjM1~~f) SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of~_ Date --sT27/83 Boring No HD83-28 (River J)Angle (from Horizontal)__.:....9..::..0.:....o ~ Feature DIs Cofferdam Bearing Coordinates:N 3226787.3 Date Started __-=3'-',/;-=5'-',/;-=8'-=3'----_ E 742990.2 Date Completed _....::3-'-/...::.5..:..../...::.8=-3 _ Logged by WMB,REB,NBB,,IEP ILEM,DAF Ground Elevation 1453.6 Rock Elevation 1381 .6 Total Depth 88 .5 Ground-Water Elevation-_-_-_ Remarks .~Hard.l):r-ill~ng 34 Ft.'.. .-'Gs""-2;78 Started Coring' ..·····3A ••·5ft;'·. c .S! 'lii 'E /II E 2 Ui .E Soil Description GW GW GP GM 1,C'"···-·--'-,~c....;...!_'_-,·~·~_·,---r__c-4----,c-....+..··;···_·-i-··--,·····_~,··-··-I G'ravelly SANDf,,Tes:sthah 5%" ,_,•.'.'__c.,,'.,.•_',"j SP sat~rated,v-erydark grey,medium, --'With-trace 'fffie 'and·-cOaTs.e-s~bangular .gravel 4 1 2 3 0/11Zc. (1)>--~Q.-gEc 01 01en /11-~OI Q.e:E /II 01-en's ;: 0-_c lD::::I .218 Il: -5 GW GM ....6 ..... ~ 7 ..... 8- - Boring No.HD8 3-Sheet 1 28 of 3 ~EIIi~~@ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of--3_ Date 3/27/83 - Boring No HD83-28 (River J)Angle (from Horizontal)__~9~0:....o _ Feature Dis Cofferdam Bearing Coordinates:N 3226787 .3 Date Started -=3"-J/c...:S"-l/C_'8:..:3"----_ E 742990.2 Date Completed _-----'3~/~5o!.J/C_'8:..:3"----_ Logged by WMB,REH,NBH,IEP/I.EM,DAF Ground Elevation __1:!:.:4~S~3~..!..~6 _ Rock Elevation 1381 .6 T~aIDep~88.5 Ground-Water Elevation_-_-_-_ c ~°cu 'E.'tj ..c::.S!0-cu-ZCL ==..c::l!u_C _Ill eu>-0lt'l :eela:;m=CL~-cuEcu-I-°ci 01>CLo Soil Descriptioncu>.2'8 CL'tj Coco!!1Il-Ec ~...cuu f!.... !:!!.a:(/).5 lIllll ocu ....cu c:l (/)jijCL a: 9 10 GP GM f7c.-cfal:Tf;e::-::TT-!:T--=" c.S!-; 'E CD E 2 Ui .5 Remarks - - - -I - Boring NoRDS 3-Sheet 2"----_of _3=-_ ?~ -SUSITNA JOINT VENTURE Boring No HD83-28 (River J) Feature Dis Gonff erdam Coordinates:N ~3...L2...2.........6.L7.!o.L8-,-7~3,-----_ E _~7,--"4,,,,2,"-,9z..;9l.!.O ....<.2 _ Core Sizes -_l'Ji'I,'IX-Ar--------- GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)_----"'-9-"'O_o _ Bearing Date Started 3 / 5 /S 3 Date Completed ---..L3-1-I-J-S-l-/.uS...,3'-----_ Total Depth __--'=8'-'8~.'-'=5~_ Sheet _3_of _3_ Date 3/27/83 Ground Elevation 1453.6 Rock Elevation 138]• 6 Overburden Thickness ---!6u..2"-o-.uO _ Ground-Water Elevation_-_-_-_ Logged by 'WM8 ,~Ell,mm:,JEP II-EM .- - I~ .- - ..... ..... Graphic Log Classification and Ph~sical Description cu~-.51:E 0 Gl fti..cQ,C FE 'El\I 0...:::I Glqf!:z FE Remarks Ii IX )(:::I.::d c.;j 0 enco.5 Borina No.HD83-Sheet 3.of 3. --' -SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet~ofni-L Date JI .!.7 103 Boring No HD83-29 (River L) Feature Dis Cofferdam Coordinates:N 3226858.9 E 743029.5 Logged by NBH,JEP/LEM,DAF 90 °Angle (from Horizontal),__~~_ Bearing ----:=~__:___:_----- Date Started ....::3!...l/'--=5!...l/~8~3~_ Date Completed __-----'3"-</'-'5"-1/c..>8"'-'30<....-_ Ground Elevation __..::1-:4.=.5..::3-:.-=8 _ Rock Elevation __---=1:.::3:..-:7~4:....;.:....:8:_--- Total Depth 104 •3 Ground-Water Elevation-=""-"'_ Remarks c.2 'iii'E CD E .E II> .5 Soil Description 7 4 1 c ~°Gl 'E.-a .c.2 0-CIl-za.~=.cf!u_C _Ill CIl>o 011):EO)0.';lD~a.>-CIlECii-I-°ci 0»a.oCIl>.2'8 a.-a CoO..!!!1lI-Ec ~...CIlu ~...I ~a:(/).5 ~1lI OCll ...ICIl CliDa.a: GW- 2 GM ,..... GW 3 -GM ~ GP 5 GM !""'" 6""" - ..... - Boring No.HD83-5heet _1,,--_of ~_ Jq E·1··.···I!!II,. SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet -L of -4 _ Date 3/27/83 - - -- - Remarks AIt"ernaf£inghard and easy drilling ~7-H:t~F1i;.. r;;9~~!~ c .2 '; 'E QI E 1: f/I .5 Soil Description Angle (from Horizontal)_--=9-..::0'--o_____Ground Elevation _---=1'--'4-=5-=3:...:.:...:8=----_ Bearing Rock Elevation __...!1!o.;3t-.7!,:;*;u.;.8i?-_ Date Started :::.3!.,./:::.5!.,./:::.8:::.3 Total Depth 10 • 3 Date Completed 3/5/83 Ground-Water Elevation_-_-_-_ GW11 10 9 8 GW c j:OlD C.'C .c:.2 0-CD-Zo.:::I:.c:l!:!u_I:_Cll CD>-0",:Cal--11:\:::1 0.(::-QIo.Cll EQI _l-Oci al>0.0CD>.2'8 0.'C CoQ~Cll-Ec j:..CDu ~...I !:!:!.II:(/).5 CllCll o QI ...IQI CJ U)mo.lI: Boring No HD83-29 (River L) Feature Dis Cofferdam Coordinates:N _---=3:.::2:..::;2=-:6:.,:8;.-:50-'8:-'.:..:9::-_ E _------=-7....:.4=_30=2:..:;9....:...=_5 _ Logged by NBH,JEP/LEM,D:AF Boring No.HD83-Sheet 2 of 4 29 SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet~of~ Date 3/27/83 Boring No HD83-29 (River L) Feature D/S Cofferdam Coordinates:N 3226858.9 E 74 302.,..9~.5oJ.---- Core Sizes ....NX""·"'--_ Angle (from Horizontal)__-71-9"'O_o _ Bearing Date Started 3/5/83 Date Completed _~3oL/,-,5"'-L-/8""-"'.3 _ Total Depth 1 04 •3 Ground Elevation 1453.8 Rock Elevation 1374 .8 Overburden Thickness ---2a...0 Ground-Water Elevatiofl............_----- Logged by NBH ,JEP I LEM 76.0 Remarks ,, Som€jmec~brkg; Qi .c E :::I Z ><c III o-o ~~ Q,C f!0 <;I ~ Ii tiocj Classification and Physical Description 2! ::1m -0g...J. LI.. 3 6 9 12 ...-.....;,......f~"."~;.·~.•.•+~.~-'i~-<w.-_._~~~+,~,~~~-l-~_....L-~--.-,..+-""'.~~.~~,"~,,_.~..~,..,.,,~".~_..._,~.~.,.n,,"" '·186~~$TAlteredPiQ~ite,tt grey, ii.li llled grained,mod-alFer "fe~Ma~ iT=~T!J!1J.nsra])sent·;···pragIo=·partryra1:"Eer :'.!to~~o:inite,;lo.l?elfracFmax" T-·-~-··Tb-(}=rm-1R-'·4.0.-().5!tme s-t l-y-Q·.::3-:().-.4-;:-·,·~ ,.,"'imed~~Ecl,'1]100.ktrong,uIll't~inea 1-••"";.,.",,,'.!",-,.,••~-t(\}4~3-'f}ior:ite,TH-mecl-greT;., ;.;-,:1 ",_•.,...;.........:',-- ---~ ,ifinetIIlea g:rain~d,fresh,clos~~ JJ.c"_..;...TJmortfr.act.~"max:..0 •.z.~,"Jnin_p .•.l1"_m.()~t ..0.3'~hard,st:tong,rf:reshunw 20%jts ,··()f·······CaC93; "~..".~~"._,_}".,__~_.""',,'+__.~~.,.~_~..o_.m_~'._w_,.o~w,_~~~M__~' Graphic Log 100 C .c .2a.C; QI> CQIg ...... .... .... Boring No.HD83-Sheet_3__of_~_ SUSITNA JOINT VENTURE Boring No HD83-29 (River L) Feature DIs Cofferdam Coordinates:N ~3....2,"",2....6l.L8.......,5.l.18..........;;9~_ E 7430 ..L9~•.L5 _ Core Sizes _NX='----_ GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)__...t.9""0_o _ Bearing Date Started 3/5/83 Date Completed _3..../r-5..L.f-!/8........3 _ Total Depth 104.3 Sheet _4 _of _4 _ Date 3/27/83 Ground Elevation 1453.8 Rock Elevation 1 374.8 Overburden Thickness _70.0 _ Ground-Water Elevation_-_-_-__~_ Logged by NBH.JEP ILEM - Graphic Log C .s:.2c:; CD> ClIl §. ! :101-0:;:..1.. LL. 3 6 9 12 Classification and Physical Description c U ~...2:c 0 CD Gi.QQ,c E 'E<II a..:I CD f!1 E!:z E Remarks Ii Ii >(:I -.. 0 ti 0 u; lEI -= - - Boring No.RD8 3-Sheet 4 of _4__ _-._1 SUSfTNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of -3 ~ Date 3/27/83 Boring No HD83-30 (River N)Angle (from Horizontal)__9::....0-=----o _ Feature DIS Cofferdam Bearing -::-.==-:::;-::-:;:--_ Coordinates:N 3226932.3 Date Started 3/6/83------==--'--;-::-'-;-=-=----- E 743068.2 Date Completed __-=3.!.../.=.6.t-/8=.;3:....-_ Logged by WMB,REB.HI.I,SEW/LEM.DAF Ground Elevati on _---=1::....4.:...:5::...:3:::....:....8=--_ Rock Elevation __---=-13"'-8=-8~.8=--_ Total Depth 66.0 Ground-Water Elevation..:-:..:-:..:-=--_ Remarks ifficulty with ample~.return~~ ormation probably oose. c .2 «i C 41e 2 '0 .E SP GW GP2 7 3 8 1 I""'" C ~°41 c."0.cO O-m-Zc.~=.c!u Q.~_C _ca 41>-0 10 :CD)c.~-41)lZl~E 41)-I-(.)0 D»0.0 Soil Description41>.218 0."0 Coc~ca-~..~...ICI.l.E Ec 4I)ua:o 41)...141)Cl!!::!.caca iDc.CI.l a: GW 5 "GH ""'" 6 SW SM ..... Boring No.HD83-Sheet 1 of --<3__ ~o !l flJj~~(f) SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 2 of 3 Date -------sT27 T83 Boring No HD83-30 (River N)Angle (from Horizontal)__-=9--=O'--o Ground Elevation 1453.8 Feature DIs Cofferdam Bearing ..,.......,...".....,..".....,.Rock Elevation 1388.8 Coordinates:N 3226932.3 Date Started '--3=../!.,-6=../!.,-8::.:3=--Total Depth 66.Q E 743068.2 Date Completed 3/6/83 Ground-Water Elevation_-_-_-_ Logged by WMB,REH,RT..I,SEWlLEM,DAF - VEl!.WITH dOBBLES ~...rl!'!ss +tl1.an· :5%....!.•""sat;\l~at;~dJ'ver~:dar*grey; !sul$JtDundtcn~.!SiIDaqgura:ffrTlI1.e~tcrt-T-·-· ~~~:_~se [~:..•...1~L;••I·.•·:······.··l··~·····.I=-_~.~-,~_..- 'COBIJ"LES :AND.BduL.DEaS .;,I .. ,.j....:_.:l-.;..~,-~-~.-+.--...".-i-"'--?--1---, t ..\r ~:-f~l j -_.....\_......_. 9 10 c ~ci 1Il E·"CI .c .2 0-Ql-zQ.~=.cl!!u_c _Ill CD>-0..,:COl"6.:;Q.~-1IlI:D~ECD -I-o·01>C1.0 Soil Description RemarksCD>.~8 CI."CI 0 Coco!!lIJ-Ec :=..lIlu ~....I !!!.a::.rJ).E lIJllI OCD ....I CD CJ CI)iDQ.a:: Boring No.HD83-Sheet _--=2=--of 3 30 SUS/TNA JO/NT VENTURE GEOLOGIC LOG WATMiA D8VELOPMENT Sheet --3.--of --3- Date 3/27/83 Boring No HD83-30 (River N)Angle (from Horizontall __9....,O....o _ Feature Dis Cofferdam Bearing Coord i nates:N ~3h12....2~6~9~3H2(,..,.~3;)._----Date Started __---...31-J./,...64!,...S...3J--_ E 743068.2 Date Completed _-"'3"--/--"6-'..-/-=8=3 _ Core Sizes -_NXl.lI.A.Total Depth 66.0 Ground Elevation 1453.8 Rock Elevation 1388.8 Overburden Thickness _~5,-,,6,-,.,-,O,,--_ Ground-Water Elevation _-_-_-_ Logged by WMJ3,REH,RLJ ,SEW/LEW,DAF-Graphic Log c u -1e Qj ~c :c 0 CD .c ....c .S!>-CD ..C\,Cl..E 'Eam0':l :lO'til 00~.9 ..:l Gl r-Gl >"0 U Classification and Physical Description <;l e:z E Remarksco!:S :l ..Ii Ii :l ~..u.><=:J en e,j e,j 0 '"3 6 9 12 III -=- - I~Blia;r,1::el"J-/Lo:ul'dn:.:t...gCt .cIQW;n f:or2ti.d;fuli, cal1hole~'. .... Boring No.HD83-Sheet of---::3'----_ ~If£l ~(i) SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of .....3.....- Date 3/27/83 - Boring No liD83-31 (River P) Feature D/S Cofferdam Coordinates:N 3227015"2 E 743107"3 Logged by NBH ,JFIl/LEM,DA.F Angle (from Horizontal)_9_0_o _ Bearing Date Started 3/6/83 Date Completed _3=-/'---6"-'/'---8::...:3=---_ Ground Elevation __----::-1-:=-4-:=-5""""0"6_"-=2 _ Rock Elevation 1_3-,9--=6~"2,.--_ Total Depth 82 " 9 Ground-Water Elevation _ Remarks Easy drilling,33 57~5 Ft...'.....;........•..~.. c ~ III'E CD E 2;; .E .i__o_~'"",.;"-r-·-~-"'·"~·""~···~~'·'"-'.-,~"...",,~-o"""-'~__ .-,---.,1'..,.-.".'---,-.- EasJtpenqtrat:ilon 3~-57~~':Et~! ......_..~"..._+--..,~,....._~~..;.~_+._.._..-;~-.,,:.~._;._.-<__....._""-.·"~w~,;,,,_,,,!-"'+'~--r_o,~~L_~~.._'-' Gra"lelly,SANDJless thart 5%silt~ldos , ..sat.:u.tated~:.•:'ie.:¢)L.dal:ilt..gr-ey.,:,.f.ilneL,tO-....·~.•......~.. coaIise,Ilound~d to subro~nded&ravel.· SP SW GW GW 7 2 9 6 3 4 5 8 ~c ~oeD 'E.'0 .c:.2 CD-Zo.==.c:!u0-_III_C C1J>-0.":El:Jlac;11I=o.~-CIJEeD-...°ci l:Jl>0.0 Soil DescriptionCIJ>l:Jl0 0.'0 CoQ~lII-~...l!...J_0 <n.E Ec CDu !!:!.a::III III o CIJ ...JCD "<n iii 0.a:: 1 GW-GM .-. - - - Boring NoH~~Sheet 1 of ~3i--- --~-._. I~I SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of--l- Date 3/27/83 Boring No RD83-31 (River p) Feature DIs Cofferdam Coordinates:N 3227015.2 E 743107 0 3 Logged by NBH,IFBf1.EM,DAF 90 °Angle (from Horizontal)_~-=-_ Bearing Date Started ...,..3-'-;1...,..6.:..,./-=-8-=-3 _ Date Completed _---=3:...:/-6:....:/-8--=3----- Ground Elevation __=-14---e...5_6...:.0_2 _ Rock Elevation --...l.1...J3~91,l;~l,.2....~.,,9,----­ Total Depth Ground-Water Elevation-=.:"""-_ c ~°Cil 'E.'C ..c .2 0-CIl-ZQ..==..cl!!u_c _Ill ~~0Ll):EC)a:;Q..~-lI)l:D::2 Eal 0 0 C»Q..oal>C)0 1lI-Q..'C ;=...Co e...lQ..!__0 (/)..5 Ec Cilu II:Oal ...Ill)CJ!:!!.«lea iDQ..en II: Boring No.RDa 3-Sheet 2 ':11 - - -! - Remarks C .2-; 'E al E 2 Ui .5 Soil Description GW GM11 10 SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet -3 ._of _3__ Date 3/27/83 - Boring No HD83-31 (River P) FeatureDjS Cofferdam Coordinates:N 32270]5.2 E 743]07.3 Core Sizes NX Angle (from Horizontal)90 0 Ground Elevation 1456.2 Bearing Rock Elevation 1396.2 Date Started 3/6/83 Overburden Thickness _5.L9~.Ou....-_ Date Completed __3..J-.t-/6U-f-/u8-':3 Ground-Water Elevation_-_-_-_ Total Depth 82 9 Logged by NBH,JFB/LEM,DAF Graphic Log - .... - - - C .c .2 Q.m 11» OlD ~ >-..lD l!!Cl ~o ~-g'Ci U g .... 5 2 It :J en 3 6 9 12 Classification and Physical Description cu::!!....2:c 0 II)(;.cc.0 E Cos0..~II) ~!!:z E Remarks a::a::>C ~.. d d 0 }m WZIA\~E SUSfTNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _3_ Date 3/27/83 Boring No HD83-32 (River Q)Angle (from Horizontal)90°Ground Elevation_----,1::-4.,.....5::-4-=-=-.-:;:0 _ Feature D/S Diversion PortalBearing Rock Elevation 1_4_2_5_._0 _ Coordinates:N 3227138.2 Date Started 3/6/83 Total Depth E 742798.9 Date Completed __3=...!..../..:...7..:.../-=.8..::3 Ground-Water Elevation--=-=..:-=..:-=--_ Logged by NEB ,.IFP ,WMB ,HI "I II.EM ,DAF ,, 0--.•--"....,,_....•....:,.."~-'~-,~,~ Remarks c .2 fti 'EQI E 2 1i) .E GW2 1 c ~oQl 'E.'C .c.2 0-QI-ZOo :1=.cl!!u_C _Ill Gl>-oll):ECI/'5.';Q.i':-Gl1Il:l -I-o·CI/>Gl>.218 EQI a.'C Q Co 0.0 Soil Descriptionco!!<lI-Ec ~-Qlu l!...I ~a::In.E 111111 OGl ...IQI CJ <II iii a.a:: 3 GP- GM I"'"" 4 GW ,~5 - - ..... - Boring No.BD83-Sheet--",-1__of -3-- 32 GEOLOGIC LOG WATANA DEVELOPMENT Sheet _2_of _3_ Date 3/27/83 SUSfTNA JOfNT VENTURE Boring No HD83 32 (River Q)Angle (from Horizontal)__9..t.101.L°_ Feature Dis Diversion Porta Bearing Coord inates:N 32271 38 .2 Date Started __-"3'-'.1-->6'-'1-->8"-'3"--_ E 7427913.9 Date Completed _3.....I<-Z......!/-'8.....3.J------- Core Sizes -~~~'lXA.---------Total Depth Ground Elevation -----"'1~4~5'-=4'-'.'--'O"--_~_ Rock Elevation -""1~4~2'-"5~.'--'O~_ Overburden Thickness 2.,::2=-..:.:.::5=---_ Ground-Water Elevation_-_-_-_ Logged by NBH,JFP,WMB,RLJ/LEM,-Graphic Log c l.):f!...!2C:E 0 Gl iii..c.c .!2 >-CD 0.C E COi...~aa.-a;0 ::I ::l G> G>'""0 ti Classification and Physical Description qJ e:z E Remarks o~2 a::Ii ::IoS)(:::l:!:!-Ui (,)U 0:::::i Il:I rn .E return,It .. 50 Boring No.HD83-Sheet ",,2__of _3..-.-. .- SUS/TNA JO/NT VENTURE Boring No HD83-32 (River 0) Feature DIs Diversion Porta· Coordinates:N 3227138 2 E 742798.9 Core Sizes _NX.l.'J.£>~_ GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)_-----"9'-"O'---o _ Bearing _ Date Started __~3u/~6u/~8~3L-_ Date Com pleted _~3.u/L7L/L:8"'3"'_____ Total Depth Sheet_L of--.1- Date 3/27/83 Ground Elevation __--=1=-4:-:S:o-4c:--:-,-::0 _ Rock.Elevation ...:.1-::4-::2_S-;,:-0 _ Overburden Thickness 22,S Ground-Water Elevation ~-::.;:-::.;:-::.--_ Logged by :NBHJJFP.~.RLJ/LEM.DAF Graphic Log c u ~Gi .S!C :c 0 ;;!!!.0 J:.2 >-!c.C E 'E0..';0):J zg'l!00UClassificationandPhysicalDescription :s aI aI>'0 g...J ~e z ECal:::J u:Ii Ii .E~..>< ::i iii d d 0 '"3 6 9 12 III -=- ..... ..j-N--0 N 0 I- - -- - ..... Remarks SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _2_ Date 3/27/83 Boring No HD83-33 (River G7) Feature Diversion DIs Portal Coordinates:N 3227126.4 E 742668.9 Logged by R TI"WMB/LEM,DAE Angle (from Horizontal)90° Bearing Date Started 3 /7 183 Date Completed -,3~/,--7,--,/,-,8=3,,--_ Ground Elevation ....1~4'-=5<..:3"--!..;.2=-_ Rock Elevation ----'1=-4-=--=.3=2..:..-=2'---__ Total Depth 43.0 G round-Water Elevation _-==:.=-_ GW I_TSllhljdulldEid~.•·•.;fJ!:nEf·tqcQCSl:rsl:!-. GM GP 2 3 1 C C oel)c.".2~a;.c .2 0-CII-Zo.:::I::.cl!!u_C _ft! CII>-OU):E CI Ca.'C;a::a:::l o.e -eI) ECI)-I-°d CI>0.0 Soil Description CI)RemarkseI»Cl O c."Co Ec.!!ft!-~...Cl)u l!!-1.-°Cf.l.5 Ec :::I !:!:!.a:ft!ft!Oel)-1C11 CJ .:=U)iDo.a:'".5 - .... Boring No.HD83-Sheet 1 ot -<.2__ 33 GEOLOGIC LOG WATANA DEVELOPMENT Sheet _2 _of ---.2- Date 3/27/83 SUS/TNA JO/NT VENTURE -\ N-...... N-N Ground Elevation 1453.2 Rock Elevation 143202 Overburden Thickness -_]L..3;J..T-~·~5---- Ground-Water Elevation..,--_-_-_ Logged by RJL.WMB ILEM,DAF c:u :::e.>-.2:c a Gl iii.0D.0 E E(lJ 0..::::l CD <.:'!:E z E Remarks ri a::)(::::l.::0 U 0 ..II!.E Classification and Physical Description Graphic Log 35 c- .c.S!a-; CD> OGl §. Boring No HD83-33 (River G7)Angle (from Horizontal)__~9-",O_o _ Feature Diversion DIs Portal Bearing Coordinates:N 3227126.4 Date Started __--"3<..LI:-'-7--'/c:-"8'-"3<---_ E 742668.9 Date Completed _---'3""/---'7:....<1---'8'-"3'--_ Core Sizes ~NX Total Depth 43.0 Boring No.HD83-Sheet 2 of 2 ~-' SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_1_of ~ Date 3/27/83 Boring No HD83-34 (River S) Feature Diversion Dis Portal Coordinates:N 3227212.5 E 742633.7 Logged by NEH,]FB ,MSC!LEM,OAF 90 °Angle (from Horizontal)__----=--=--____Ground Elevation 1...:4t..5,c4:t..'~.9.L-_ Bearing Rock Elevation 1442 .,8 _ Date Started 3/7/83 Total Depth 32.4 Date Completed ....:3~/'-7:....!-/.:::8.:::3 Ground-Water Elevation _ GP GM2 1 c C ~°Gl 'E.'0 .S! -'=.S!0-CD-zo.:::1=-'=!u Qi_lII 'Ea.7; _c o.e CD>-0",-Gl :E Qm:::l EGl -~()ci Q>0.0 Soil Description Gl RemarksGl>.218 0.'0 Co EQ~<a-~...Qlu E-I cr (I)':Ec o CD -1Ql CJ 2!!:!.<alii mo.cr 'lii(I).: '""" - Boring No.HD83-Sheet 1 of 234--- SUSITNA JOINT VENTURE GEOLOGIC LOG WAUNA DEVELOPMENT Sheet_.~_of_2__ Date 3/27/83 Boring No HD83-34 (River S)Angle (from Horizontal)9"'-'O"'-o _ Feature Diversion DIs portal Bearing _ Coordinates;N 3227212 -.5 Date Started _~3-1-1..L7-1-/J.l81..;;3~_ E 742633.7 Date Completed ---13'-/-1..1-7-/-1.....8 ....3 _ Core Sizes _NXl.lIA Total Depth __....13""2..;../.::14 _ Ground Elevation 14_54_,_9 _ Rock Elevation 1442_-"...,,8,-__ Overburden Thickness 7 ,0 Ground-Water Elevation _ Logged by NBH,JFB,MSC!LEM,DAF Graphic log c Q :::!!~.2Cl!!:E 0 .0 as..c .51 >-l!!Q,c E Cac;t»::I ~g'<lI 00UClassificationandPhysicalDescription ..::I CD CD>'0 g ....<;I ~z E Remarksco!!::2 ..Ii a:><::I !!:!.II... ::::i 0 e,)c.:i 0 U; 3 6 9 12 lEI .5 Boring No.HD§:}-SheeL2--of 2 - - ~I -. - SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of --3- Date 3/27/83 Boring No HD83-35 (River G8)Angle (from Horizontal)9-""0_o Ground Elevation_----=1....:4-=5~8~.'__'4'______ Feature Seismic Line ES-D Bearing Rock Elevation __....::1=--4'--'0:::..:6::...:...;9::.-_ Coordinates:N 3226804.8 Date Started _~3...../.L-7...../....8....3 Total Depth 71 5 E 743456.5 Date Completed 3/8/83 Ground-Water Elevation-=:=..._ Logged by NBH,IFB,RLl,WMB/LEM,DAF @ c .S:! fti 'E ~Remarks 2 Ui ..5. GW GW GM I--''''·'''"~''''l''"-'''··'''..'''·"~-''''-.e:.·'''-''''-J-'"""~""--+'---·--·--f·--·-··"" GW GP 6 9 7 5 8 4 c ~ciQl 'E.og .co2 0-QI-za.;:,::.c!u-IIIa.:;_c a.i;:CD>-011)-CD :EelIll;:'EQI -I-Uc:i el>a.0 Soil DescriptionCD>el°111-a.og ~..Co f...Jo~._U (/).:Ec Qlua:OCD ...JQI <:J!!!.111111 aia.(/)a: 1 GW GM 2 GW ~ 3 .- - - Boring No.RDa 3-Sheet __1_of 3 35 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of~ Date 3/27/83 Boring No HD83-35 (River G8)Angle (from Horizontal)_----iL9~Q~o _ Feature Seismic Line E5-D Bearing Coordinates:N 322680/1.8 Date Started __----'3:!.J/L7!.J/~8~3~_ E 743456.5 Date Completed _--,3~/L:8~/L:8~3~_ Logged bV NBli,JiE ,RLJ ,WMB ILEM,DAF Ground Elevation __--']1...:4:1:..5.....8"'--'--',4:t....-_ Rock Elevation .J.l..=l4l.l.0L16J..-:9~_ Total Depth 71 .5 Ground·Water Elevation _ -. -. -I c C ~OlD c·'tl ~ .c .2 (1)-zo.:I;:.c!u LI:.I0-_l1li C--_C 0.1::CD>-011)-CD :E gjQ.l\1 11:1:1 EID -l-Ud C1>0.0 Soil Description CD RemarksID>gj0 cg-0."0 3:-Co 1!....I EC.2!_U (/),5 E c IDu ::IIa:OlD -'CD Cl ..Ie alai aiQ.a:u;en .5 Boring No.HD83-Sheet 2 35 Of_3_ SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet l-of --3....- Date 3/27/83 Boring No HD83-35 (River G8) Feature Seismic Lin~ES'--'-lJD,--- Coordinates:N 3226804.8 E 743456 5 Core Sizes _NXI.lA _ Angle (from Horizontal),__...;;;9'J,OLo _ Bearing Date Started -.::3i-1-/~7'..J/c.(8).,,;3).-------- Date Com pleted ~3...../,-,8"-1-/8,,-,",-3 _ Total Depth __J.7-dl.......'--"S"--_ Ground Elevation __'...,4,...5J-'8u......""4:.-_ Rock Elevation 1406.9 Overburden Thickness M...JL._ Ground-Water Elevation_-=:=:-_ Logged by NEB,.IFB ,RI..I ,WMB /I.EM F""" Graphic Log cu"::!!.G;.2C:E "m.c .2 >-e e Q,c .a aft;C):=:=C)III (J E E 0 U -0 Classifica1ion and Physical Description ...:=CD ~CD>"0 ~....l ql !!:z E Remarksco!!-= :=Ii Ii := !!!....1.1.><... :::i u;(,)(,)0 7ii3 6 9 12 III .5- - - Boring No.HD83-Sheet --,3,,--_of 3 .~SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_1_of_2_ Date 3/27183 Boring No HD83-36 (River G-9)Angle (from Horizontall __----"9'-"O'--o Ground Elevation 1456.8 Feature Seismic Line ES-C Bearing Rock Elevation 1432.8 Coordinates:N 3226826.6 Date Started 3/8/83 Total Depth 43.6 E 743569.8 Date Completed 3/8/83 Ground-Water Elevatiorr_-_-_ Logged by WMB.RLJ ,NBH,JFB/LEM.DAF ..- c ~-o Gl 'E.".co2 GI-za.~=.cl!!u_tlI °ltla-;_C a.e;G)>O -G):eel11I:::11 E G)-l-Oci eI>a.o Soil DescriptionGl>.218 a."Coc~<11-Ec ~...G1u f-l a::(/).5 o Gl -1Gl C)!!!.~<II iDa.a:: Remarks c.2 ftj 'E Gle E III .5 GW 1 GM "~...'"'"~"~."... GP 2 GM 3 4 - - ,...., - Boring NO.lID~~Sheet ~l--of 2 SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet _2 _of __2_ Date 3/27/83 Boring No HD83-36 (River G9) Feature Sei sm;cLine ES-C Coordinates:N 3226826.6 E 743569.8 Core Sizes _-'NX=_ Angle (from Horizontal}__....9.>£O_o Ground Elevation 1456.8 Bearing Rock Elevation 1432 8 Date Started 3/8/83 Overburden Thickness __2"-'.I.-.o-c0u-_ Date Completed 3/8/83 Ground-Water Elevation"_-_-_--'-_ Total Depth 43.6 Logged by _ - - "Sollie evidence of .grinding. Graphic Log c """'tiu::e ...~c :c c GJ i;S!.Q.c .2 >-e Q,C E C'Q.'t;CI ==g'l!"0 =GJ GJ>'0 U ~-I Classification and Physical Description (;J a::z E RemarksClll::=..a::~=~...u.><=::i en d 0 0 II)3 6 9 12 CD .E """! 43.6 Boring No.HD83-Sheet -2--of 2 ':I~ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of 5 Date --sT2 7783 i" Boring No HD83-37 (River G2)Angle (from Horizontal)90°Ground Elevation _.=:1-.:4.:::6.=:2:...!.---"5'---_ Feature Seismic Line ES-F Bearing Rock Elevation _---=1::..::3=--0:::..;9=--.::....0-=--_ Coordinates:N 3226983.9 Date Started 3/8/83 Total Depth 155.0 E 745913.9 Date Completed 3/9/83 Ground-Water Elevation_-_-_-_ Logged by NBH,JiB,WMB,RlrT/T.EM,DAF Remarks c ~III 'E GI E 2 '1ii -= Soil Description u :Co 0.0e..lo GW GW GW GW GW GP GM 'tl .c!-lDa1>Co.3~a:: 4 9 7 5 6 2 3 1 8 °GlZa. GI>--I-o.'tlEc III IIIen 10 C .c .2a.,; GI>CGI~ f .- - - ,.... Boring No.HDB 3 Sheet _..L-_of ------5- 37 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _2_of ~ Date 3/27/83 Angle (from Horizontal)__...::.9--=O'-o Ground Elevation _=.14...:.....:.6=.2...:.•...:.5 _ Bearing Rock Elevation --1l-,3.:l:10U:9~~e=__=__--- Date Started 3/8/83 Total Depth 155.°ft. Date Completed 3/9/83 Ground-Water Elevation _ RLJ!I.EM,DAF Boring No HD83-37 (River G7) Feature Seismic Line ES-F Coordinates:N 3226983.9 E 745913.9 logged by NIUi,JFE,WMl3, c ~OlD c·"C .1:.2 o-lD-za..~=.cl!!u_c _I'D lD>o 011):COla.as 0.>-GIca~EGi -l-oci ClI>0.0 Soil DescriptionG>ClIO I'D-o.-a ~...Co l'!!....o.!!.-°en.5 Ec CUu ~~ftIft1 OlD ....GI CleniDo.~ .'j, - - Remarks Co:;: III C QJ E E <I) .5 Water 87.0 -88.0 FL r-;..::..=..:~(;R!VEt;·'ITH~OBBL~S»If)~20r.\~qa;r$e. _~.Sll*-a.•.~.te.§ILth~rL.~%~.$J1J:.~..W~t¥.y~;ry~-. <4fk.gr~y t-subrou1j1ded,lo .su~angular. fme tol coarse~.,. GW 19 17 18 16 15 14 1 ? 11 13 Boring No.HD83-Sheet --,:2,--_of 5 37 --' -SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __3 _of_5_·_ Date 3/27/83 BoringNo HD83-37 (River G7)Angle (from Horizontal)90°Ground Elevation 1,462.5 Feature Seismic Line ES-F Bearing Rock Elevation --J:-l~3.yO~9c...~OI__---- Coordinates:N 3226983.9 Date Started 3/8/83 Total Depth 155.0 E 745913.9 Date Completed 3/9/83 Ground-Water Elevation _ Log.ged by NRR,JFB,WMB,RLJ!LEM.DAF Remarks Refusal' Started coring at -T43~'S Wft~..... e .2 (;j CGI E .5 II) .$ GP GC GW GM GW 25 23 24 21 22 ISO c ~-OCII 'E."CI .e.2 GI-Za.:::J=.el!!u.2c _til CD>-0",:Calat;a.e -GIID:::J SCD _I-o·01>e.o SoU DescriptionGI>.2'8 a."CI 0 eoQeIltII-Se ~...Glu l!!...1 ~a:(1).$oGl ....11I Cl..-~1lI jia.a: r -20 GP ".... ..... - Boring NOHDS3-Sheel---=3'i--_01_S--- 37 SUSITNA JOINT VENTURE Boring No HD83-37 (G2) Feature Se;sm;c LiD e ES-F Coordinates:N 3226983,9 E 475913,9 Core Sizes _Nfi\~r---------- GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)__....9""'OL-°_ Bearing Date Started 3/8/83 Date Completed -3~/...9+-/.Q8-Oil3------:---- Total Depth 155 0 Sheet~_of --.?_ Date 3/27/83 Ground Elevation 1462,5 Rock Elevation 1309 0 Overburden Thickness - Ground-Water Elevation Logged by NBH.JFB.WMB.RLJ /LEM ~ Graphic Log c (,):1!.....2C:c Cl CD ftiCD.0.'=.2 >-e ...Q,Q e cQ.a;CI ~';g'al 00...~CD 0»'0 U ~...I Classification and Physical Description q e:z E RemarksQ..!!!=~...Ii Ii ::::I !!!....U.>C =:::i en 0 c.:i 0 II) 3 6 9 12 lEI .E - -!", - Boring No.RD83 Sheet _-----4.-of _5 _..., Ii SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet3_of-5 Date 3/27/83 ..... Boring No HD83-37 (G-2) Feature Seismic Line ES F Coordinates:N 3226983.9 E 475913 9 Core Sizes ----=:NX:.:::.._ Angle (from Horizontal)90° Bearing _ Date Started 3/8/83 Date Completed -~3,;)..l_l~91_/o8..;)3----- Total Depth 155 0 1462 5 1309.0 ·WMB.RLJ/LEM~ Graphic Log cu~a;.2C:c "t;jJ:l.c.2 >-!c.c E CamCl::;,«I 00UClassificationandPhysicalDescription ...::;,QI !"""D>'0 ~a::z E Remarksco!!.c ::;,«~::;,...)(...~:5 en cj cj 0 iiilEI.5 ...... - ...... ..... Boring No.HD83-Sheet 5 of ~5,,--_ '1"7 r iii'S ~~...ffl\~1i!I ~1~\lW SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT -.~._. Sheet 1 of 2 Date ~7/~ ...... Boring No HD83-38 (River G1) Feature Seismic Line ES-F Coordinates:N 3227099.9 E 746148.4 Logged by NBE,IEB/LEM 90 °Angle (from Horizontal)_~,.....=.-=--_ Bearing Date Started __---=3'-'"/,...:;9...:../,...:;8..;:;3 _ Date Com pleted _....;3=-/'-'9:o..!/c...:8=-:3::...-_ Ground Elevation __=-1.....,4~6...;;;2"';;"..;,.7----,,....,....__ Rock Elevation 1 ,368.2 (Refu sal Total Depth 94 .5 Ground-Water Elevation _ c ~°Il 'E.'0 .c.2 0-CD-Zc,:::1=.cl!!C)_C _CD CD>-0",:e Cla.,;c,e:-CD11I::1 E GI -...°ci CI>c,o Soil Description1Il>Cl O lll-c,'O.~..Co l!..1O.!!!_0 en':Ec CDC) !:!!.a::CD CD OCD ..III <'en iDC,a:: Remarks c.2 iii C GIe 2 in.: GW GP GM E-~~~-fl:~~1~ 3 2 1 "'"" - - Boring No.HD8 3-Sheet ----'1"----_of 2 38 SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 2 of 2 Date ~27 7"B?: ~., - Remarks Cdrebarrel ."1 won't go beLow 56:~'Ff:: _.Hard ..Drilling @ 871-89 F1t.~ =:8...c CD E 2 Ui .5 Ground Elevation --=l:..J.L4:...:6:.::2:..:.:...:7:....-_ Rock Elevation _l~.3~6.!o!8.........2--l(~Re~f,J"ut;:s>.CaL.lllo.,L) Total Depth 94.5 Ground-Water Elevation _ Soil Description 90 °Angle (from Horizontal)·__--=--=---_ Bearing :--:--_ Date Started __-=-3L/~9L/8~3=--_ Date Completed __=3~/--=9:.L/_=8'_=3'----_ GP GM r~:i'aiJj~p.l3Ee.-f GW GP GM 10 c ~OlD c·-a .c .2 0-4))-za.:::1=.cl!!u_01ac;-=a.e:lD>-01tJ -4)):E CIW:::I _F (J.CI>4)):-.218 E4))a.-a (;)=0 a.o C,,2 Ol-E c j:...4))CJ !-J ~a:00.5 tIlm OlD ..J4))ClrniDa.a: Boring No HD83-38 (River Gl) Feature Seismic Line ES-F Coordinates:N 3227099.9 E 746148.4 Logged by _ HD83-Sheet 2 ot_-=2_ I"'" I SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of l- Date 3/28/83 Remarks ",,',-::"" c .2-;; C lD E .5 Ul .E Ground Elevation 1462 2 Rock Elevation ]309 7 Total Depth 168.°Ft. Ground-Water Elevation _ 1. Soil Description ......--~._..:.--,~~..;.--;'-.--~·,-'-,·";:L·-·--,···;..~~··i--''"·,·:........-'',··-··-;.-;.-,.-,L ..L--....;,~-,.~..,''f'~.-~- _..;-..•l j :".'"r"j ;~ ~v·-"""-·-···~~o~,·...,,--~-·~r~~'---··ij~·_'_r-~T.-_t;·--l·r~~·-~~T~..··~~-: GW GP GM GW GM .".c! -QIC1>Co 4lu...1ma: 'E.~=Oil) °0~.. OlD iDa. 7 1 2 3 6 °GlZa. lD>--I-a.."Ec III III II) C.c.2'E.G; lD>QGl ~ Boring No HD83-39 (River G4)Angle (from Horizontal)__....:9<..:O:<..o _ Feature Seismic Line ES-I Bearing Coordinates:N 3227400.0 Date Started .=.3.L/.=.1-"'O.L/-"'C8.=.3 _ E 746828.3 Date Completed _----"'3~/-=1~O.L/~8.=.3 _ Logged by WMB,HI.T,BEB,IFB/LEM,NBH 4 r .....5 GP-GM ..... ..... ..... ..... Boring No.HD83-Sheet ----=1=--_of 5 39 ~rlD!~~@ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT -.....1 Sheet 2 of~ Date 3/28/83 - Boring No RD83-39 (River G-4)Angle (from Horizontal),:....._---=-9.=.0_°_ Feature Seismic Line ES-I Bearing -=.:=---,-:--_ Coordinates:N 322740000 Date Started __---=3:.L/,.=1:.;:0:.L/..::8:.=3:.-_ E 74682803 Date Completed _.....:3:::J/c...;1"-'0:::J/:....::8::.::3=---_ Logged by WMB,FJ.J ,REH,JFS jLF.M,NBH ~-oll)'E."CGI-za,:::J:::.c!~_C _CG ll)>'0U'l :C gjlD:::J a.e;-ll) Ecu -~°d til>a,o Soil Description010ftl-Q,"C ii ...Co f...l.-°(f,I.5 Ec ll)~a:CG.u OGI ...Ill)C) (f,I mQ,IE: GP GM I-----~+_ Grou nd Elevation __1:=..4-,--",-6=.2-'.0=.2 _ Rock Elevation _-.J.]..:l3u.O~9,"",~7"'8'----::--::=--- Total Depth 16 .0 Ft. Ground-Water Elevation-'-""-""-~_ Remarks 1., j - -'1 Boring No.RD8 3-Sheet ~2=----_of 5 ..,n --SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _3_of --5-:-- Date 3/28/83 ""'"I Boring No HD83-39 Angle (from HorizontaIJ __----"-9-"°'---o _ Feature Seismic Line ES-I Bearing Coordinates:N 3227400.0 Date Started ~3tl..L-/....l""OJ-/"""8oJ.3 _ E 746828.3 Date Completed __~3oi.J/L,1"-'0"'-'/'_'8"""3L--_ Logged by WMB,RLJ,REH,IFBlT.EM,NBR Ground Elevation ---l462,.2---- Rock Elevation 1309.7 Total Depth 168.0 Ft. Ground-Water Elevation_-_-_-_ C .~<;cE Remarks 2 U; .5 GP GM I-"·:-·"·-'c·.c··.·····~+····_;······.:_..~+-;-.l--;--•.•+-··········-;-··c-···_···L..•.•••.J 25 26 24 23 18 19 GW GM !""" GP 20 GM ~ 21 .- 22 GW GM c ~-°Gl c-"0 .cO GI-ZQ.:::I:.c::!u.5!c _IllQ.~Q.~GI.>-OlD -GI :E CI!D:::I EGI -I-Og CI",Q.o Soil DescriptionGI'".218 Q."O CoC,!!!1lI-E C ~..lDu l!...Ir--!:!:!.a:en'=~1lI OlD ...IlD C'iijQ.a: GP17GM Boring No.RD8 3 =--Sheet 3 39 of_-=.5_ ~(g) SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 4 of_5_ Date ----sT28/83 , Boring No HD83-39 (G-4)Angle (from Horizontal)90° Feature Seismic Line ES-T Bearing Coordinates:N 3227400.0 Date Started __3~/J..'.I.lO+I..o8L,;3L-_ E 746828.3 Date Completed _3.l.</'-'uO,LJI'-"S....31----_ Logged by WMB,RLI 5 RER,.IFB/r.EM,NBH Ground Elevation 1462.2 Rock Elevation 1309 •6 Total Depth 1 68.a ft Ground-Water Elevation_-_-_-~_- ~-°CD 'E."tlQI-za.==.c!u_C _Ill CD>-Ow :EO)In=o.~-CD ECil -l-Ud 0),..0.0 Soil Description Remarits0).0 ca-0.":I:"-Co ~....._U CI).E E c CDua::caca 001 .....Gl 0 '""llCI)iDa.a::1 Boring No.HD~3-=-Sheet _4__of __5=-_ 3q i"""" i SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet~of~ Date 3/28/83 Boring No HD83-39 (G4) Feature Seismic Line ES-I Coordinates:N 3227400 0 E 746828.3 Core Sizes -li*"'lXA---------- Angle (from Horizontal)90 0 Bearing _ Date Started 3/]0/83 Date Completed ~31-/*1.yO.J-/-l;l8.,;l3>------- Total Depth 168.°it. Ground Elevation __1462 02---- Rock Elevation 1309 6 Ove rburden Th ickness ...:;1;;...4'-7'--0;;...0"--_ Ground-Water Elevation_~_ Logged by WMB BLl BEE lFB'LEN,''-''~:''''.:'r , .... .... Graphic Log cu":!!.Gi ~C :c Cl 2!CD .a ca.c.2 >-..c.c E Co.m CI :::II =g'ftJ a0(; ..:::II GJr-CD>'0 g ...Classification and Physical Description ql ~z E Remarks c..!;:::II ..a::a:::::II !!:!...u.)(.:=~en d d 0 <II3 6 9 12 CD .5 r- .... Boring No.HD~~-Sheet _5'"---::_of 5 ..... SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of _1_ Date 3/28/83 Boring No HD83-40 (River G-3)Angle (from Horizontal)9_0_o Ground Elevation 1,470.6 Feature Seismic Line ES-G/H Bearing Rock Elevation _ Coordinates:N -=3-=2-=2-=8-,=2-=8~5-"-.,,5 Date Started 3/11/83 Total Depth 38.0 Ft. E 747386 .5 Date Completed ~3l..J.I......lul.....I,-,8"",3,,,---_____Ground-Water Elevatioll'::::.::-:::.::-:::.::-=---_ Logged by HI.I ,MPH II,EM -.Pi.pecocked-ag . @:38.0 FtoBit _.1?r2lf~l!,_c:asing 5~0.-I!IAM~ct· _,J!l~_?5~~!~i:!,L~~._ 2 ,Ft.,moved Ihole r~drilf '..•..,'•. ,,\,,., -'~_.T--'.+-----.--;-r--..~~.._"'_.;..-~-L.." d.pec~cked'at _",-8L~Ild.38.,ELL·..~_ m6ved.back .~hree :time tedr:ili •.-~~.='.J..~-%l-..···~::~·;el:::g?'·?iL ,! -'-G~l:>±e·i-to-···~i.d sllrfac~layer.3.t ._Zj:~_ft_~~'-QJ:!cgts,ve C ~ '"cE Remarks 2 1ii .5 GW GM2 3 1 50 c ~oQl c·~ .c .2 0-QI-ZOo :I::.cl!!u_C _Ill QJ>-0",:Ec:»0:;Q.e:-GlIID:I EQI _l-Ud c:»>0.0 Soil DescriptionQI>.218 Q.~Coco!!1lI-Ec ~..QJu l!..1 a:en':OQJ ..IQ1 CJ!:!!.III III iiiQ.en a: r- 4 !""" GW 5 !""" -6 GW, GM !""" r ! I""" ,..,.,. Boring No.HD83 -Sheet _1__of __1_ 40 r SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of ~ Date 3/28/83 M,.'...-W~.-t'.~.~--'~.. (,... Remarks c ~as C QI E.e Ul ..5 .rJl.gtIDl.eL~..-=+. ~J:.iri:~~ate1-:--t~;-,··:-t~t"·~~L·-··~tT""~-·;~ Soil Description GP GM QI-_IIIc.e:EQl «l-en': ==0-_c 1Il~ .218a: 45°4 9BoringNoHD83-41 Angle (from Horizontal)Ground Elevation 1,71. Feature HIS Cofferdam Bearing -"'0.....9...,,8'-°Rock Elevation 1,413.2 Coordinates:N 3227786.1 Date Started 3/12/83 Total Depth 104.5 Ft. E 747464 0 Date Completed 3/12/83 Ground·Water Elevation ---""" Logged by RLJ •MPH,REB ,,TER ILEN,NBH . I""'" 1 SM I""" I""""2 5 SPr-SM -GP GM r- I!'"'" I I ..-r ...... ...... ..... r - -,, r Boring No.IU>83-Sheet ---,ll~-of _4- 41 -j,~fmlA!~~(IJ SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 2 of 4 Date -m8~ 8 4 45 °Boring No HD 3-1 Angle (from Horizontal)-'--Ground Elevation __-=1'-'4'-'-7-=1:...;.:-.::9:--_ Feature u/s Cofferdam Bearing Rock Elevation __-=1'-4~1'"::'3"-'::'.2=-_ Coordinates:N 3227726.1 DateStarted 3/11/83 Total Depth 104,5 Ft. E 747/164.Q Date Completed 3/12/83 Ground-Water Elevation _ Logged by RLJ ,MPB,REH t JFB /LEM,NBH iJl. - Remarks c .2-; EQI E 2 Ui .E Soil Description s~n~y ~~VEL"WITH'•••~QBBLES~T ?tIZ%.hilt, .VerY,·aeil$e~:alm'd~rit oh.ve..grey';ifine+'fo=f5afSt~-Tr .,"i'fo·:s~l>"iol.iiide(r;+·;.·~~-'-- o~c¥~:i.o¥t~b,lde.r~i ..'...,..r·······C·.::1········....il ~--r+.~._+-._-."---l-i--'--'--+.--l ..1 '" 'IGP GM 15 14 16 12 11 °al -J C .'C 0-GI-za.:::1=.cl!!u_C _aI 41>-°ltl :COla.~-41ll:I:::I -I-(.).Q> QO EQI a.'0 0 Co a.o ca-;:..~..1-(.)en":E c GlCJa::alai oQl ..141 0eniDa.a:: 10 100 Boring NoJID83-Sheet_2__of 4 41 SUS/TNA JO/NT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet-.1_of_L Date 3/28/83 Boring No HD83-41 Feature U/S Cofferdam Coordinates:N 3227786 1 E 747464.0 Core Sizes _NXUA _ Angle (from _Horizontal)45 0 Ground Elevation 1471.9 Bearing 098 0 Rock Elevation 1413.2 Date Started 3111/83 Overburden Thickness 57.3 (vert) Date Completed _3J4--/.l-142-1-/u8..;13'--,-Ground-Water Elevation--=---_ Total Depth 104.5 ft Logged by RLJ ,MPB ,REH,JFB/LEM,NBE ......~..........'-..+-w'-_·~~-->_·,~,.;.,4~~.~:~~---t-~.-'-;~-,-,-·-~7+~:·1~·~-··''''-'-~-~''~-~'0-' 84 ~..~..a8.A]tetiedDiql:iJtte i ]ttg~q.y .mecl rained ..·-sl-modtialtered"·mddtfract"",.,......,.....,:...,,....",;..".......-......rr·......'..; ,ma&~rr:::rr;nm~..(r~~rn~rd.~~ng;tUii1rfl~::~ ::ftiestr,.a~rwe.;!:~lteaqQ3··J1t·:fif..]lin~st' E ":"'_L-:._",~..,~;......"",:..;'~:,.-~_·t :q~Gjl"8..8-:Q6.2 .=itte...MJ~t~iif;;}itrJ(Fxylrt= P]agiLd,..HcirnJj'Bid ..WAsome.qtz.:..frSll.. ~v,L"_.~_W_~.'~~~',"_'~_:"~~;~_':__N_"'"_'~'__,.,"._."...,J.,,".~....+-~_f..-~,"':'....v_,L_~~r'__~~~':~w __:"..---+-1-~_ I Modtl.,.ftiClct.Maxt~6;niinO~05;i• 'trfostflIyn~4-0L8exce.ptclose]:fract. k ..·..··,-..·--+...r:t'..En!1li;:~9~·;.··~···Marg~,-·s'Crg..,::·fxslr;wl!t ..;;.._··_·.. rFJ ..l1l.cidt .Festains ·on jttsTwAs..dnierCaCOj '-~""9{LJ::l04J~~E;;;;d·:D..~~~tt;~M~dt:-+"-· Lt ra,med rained.sJtweathered.· r- Graphic Log c u ~...~c :c 0 CD l!!.D.<\I.J::.O >-CD Q,0 E Ca.:;gJ ...=8'<\I 00~...~CD I"""CD >'0 U g~Classification and Physical Description q !!:z E Remarks 0$-5 ~...IX!Ii ~...I&.)(~!!:!.~u;c.)c.)0 '"3 6 9 12 lEI .5 ;~ - ..... ..... - Boring No.HD83-Shee1--l3,--_of 4__4L ~.··.A.~~ SUSITNA JOINT VENTURE Boring No HD83-41 Feature DIs Cofferdam Coordinates:N 3227786,1 E 747464,0 Core Sizes _...,NX~_ GEClLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)45 ° Bearing 098_°. Date Started 3/11/83 Date Completed _3.J+-/....l.2+/.g8-.d3---__ Total Depth 104.5 ft. Sheet--4 _of--4_ Date 3/28/83 G round Elevation -----!-14/1.J.7-!1",--J;9#----- Rock Elevation 1413.2 Overburden Thickness 57.3 (....ert) Grou nd-Water Elevation __-'--_.,.--__ Logged by RLJ ,MPB,REH,JFB!LEM,NBH Graphic Log cy~Ql .S!C :c ..-;l!!.c~o ::0-GI Q,Q e 'E .CI ..=",<1J"5:;0 ::l gj ..a ::l CD CD>'0 U Classification and Physical Description <.;I e:z e Remarks c,!!.;:l ..a:Ii )(::l..U...~:J iii cj cj 0 'lii3 6 9 12 m ..5 --=4,--_of _-=-4_ ~ i. - - SUSITNA JOINT VENTURE SOIL BORING LOG WATANA D'EVELOPMENT Sheet_1_of ~ Date 3/28/83 Boring No HD83-42 (River D)Angle (from Horizontal)__....:9'-'O:;...o Ground Elevation 1-','-'4_6....:2~._1 _ Feature B Main Dam Bearing Rock Elevation __---:1::....z...3=-=..9=2....:•....:1'----- COOrdinates:N 3226779.4 Date Slarted __-=-"~Total Depth 127.8 E 745042.1"Date Completed Ground-Water Elevation_---_ Logged by RJL,MPB,REH,JFB/LEM,DAF Remarks c.2 iii'E II) E .5 III .5 ,",''dense,~aturilted,;grey!fine!tpcoa'J;"se.7 6 5 4 3 2 1 -c ~-°CD 'E.'tJ .co2 11)-za.::1=.c~(,)o2c _'II cu>O 0ll'l :E Clat;a.e -culD::I ECD -I-()c:i C1>a.o Soil Descriptioncu>.~S a.'tJ CooJ!'11-Ec ~..11)(,)!...l I"""~II:en.5 c'.lG OCD -I CD CJ I iDa.II: I~ - - ..... Boring No.HD83-Sheet -"*1--of __4,,--_ 42 SOIL BORING LOG WATANA DEVELOPMENT Sheet _2__of ~L Date 3/28/83 SUSITNA JOINT VENTURE Boring No DH83-42 (River p)Angle (from Horizontal)90 0 Feature E Main Dam Bearing _ Coordinates:N 3226779.4 Date Started 3/13/83 E 7q5(M2.1 Date Completed 3/14/83 Loggedb~JL,MPB,REH.JFB/LEM,DAF Ground Elevation _--=1:....:4:...::6:.=2~.~1'--_ Rock Elevation 1~3:::!....:!..9=.2~.=.1 _ Total Depth 127.8 Ground-Water Elevation __==-_ ~-OlD 'E."CIGI-za.::I:.c'!Col..2c _lU 1Il>-oil):c~a.>-GIa:l::l e:D -I-(J.01>a.o Soil Description.2'8 a."tl Q ColU-~""l!...I<1.1.5 E c Glua::lUlU Oel)...lei)CI <t.l iDa.a: 8 9 o 1 C .2-; 'E III E 2 iii ..5 Remarks ~ I '[ J - Boring No.HD83-Sheet 2 42 0,_-.:4_ r .....SUSITNA JOINT VENTURE Boring No _R..::;D-::;S-::;3_---'4-::;2=---_ Feature Main D.;ll,ll Coordinates:N 3226779.4 E 745042.1 Core Sizes --"NX'""'-"-_ GEOLOGIC LOG WATANA DEVELOPMENT 90 0Angle(from Horizontal)__--".-"--_ Bearing Date Started __--"'3'-'-:/--"'1=3-'-;/.=:.8=3 _ Date Completed _3""'/L.1",-4"-'/L..:8::..:3~._ Total Depth 127.S Sheet---3_of _4_ Date 3/28/83 Ground Elevation __----"--1::<4-"6",,,2~1 _ Rock Elevation -""1__3'-'9"'"2~1 _ Overburden Thickness 59.0 Ground-Water EJevation _ Logged by RJL,MPB)gEH).TEB fI,EM,DAF Graphic Log C l!!.cO >-Gl'S.:;01 ....E!g':s°tiGl>Ci g...l C,!!=:s ... !:!:!. ...II. ~iii 3 6 9 12 - ..... - 1""" .85 r'"'" 90 30 70-__9.5. - cu:f!.....2:c 0 Gl 'ii.cc.Q e cca0...:s GlClassificationandPhysicalDescription<;J !E z e Remarks a:a:><S0(.)0 '"r:D .E .Boring No.HD~~-Sheet _~3,--of 4 SUS/TNA JO/NT VENTURE Boring No HD83-42 Feature E Dam Axis Coordinates:N 3226779.4 E 745042 1 Core Sizes --"NX."""'--_ GEOLOGIC LOG WATANA DEVELOPMENT Angle (from Horizontal)90° Bearing Date Started 3/1 3/83 Date Completed 3/14 /83 Total Depth 127.8 Sheet __4_of_4_ Date 3/28/83 Ground Elevation -::1:.,;4:...,6:-::2::-.:..,1::--__ Rock Elevation 1_3---:=-9-=-2_0-::1 _ Overburden Thickness 5900 Ground-Water Elevation _ Logged by B1L,MPB,REH;JFB/LEM,DAF Graphic Log C ..c .2aC; GI > OlD §. 150 ! :::I U :::I...o Classification and Physical Description c....2!c; E 'E :::I lD Z E)(2oUi !II .E Remarks Boring No.HD83-Sheet ---=4,,--_of __4__ 42 .... jD SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT II Sheet 1 of 4 Date 3128/~ .- Boring No HD83-43 (River C)Angle (from Horizontal)=-9..:;.O_o _ Feature £Main Dam Bearing -:--":""'"'"':"-:--_ Coordinates:N 3226736 8 Date Started _--=30.</.,.;1"-4;..1/'-'8::..:3"--_ E 745055.6 Date Completed -'3"'-'/-'1"--C4'-!./..;::8c::3 _ Logged by RLJ ,MPB,REB,,rEB !TeEM,NBH Ground Elevation 1,..........4__6_1-'-.._1 _ Rock Elevation ---"1'-l•...,3"-'8~5"-L.7.!--__ Total Depth Ground-Water Elevation _ Remarks 'H,AM~,OI .L~.L ... "1 ~;---c""---·f~-'·~-~'--+~_·~·-·.}...·!f 'Nawate'i--r"eturn 42.48 feet ··5~~f 1 c .2a; C 1IJ E ~tn .E Soil Description ;"i:~E~-~nkd:l:rrnt-·:tD-'doarnrd_-'s~mi···-·-_·5~ljZ%:;iIl:i:~-'i •••.....i·····;'.:.'...:.....' i -j-'. ~-'-.4-1~·~~:-·-~-~·--'·-~·-i--~·~··;~-·-r--t···L~..~~.--...-Sublroq~d!ed!·tq·suban!5\l,lair;fi;netq .coarse,;ioccasfanall'cobble.,: ~.+--,~_.,-_.._"._..~--y---~..._._,.--,--.>_.~-",,~.~+..~_..,.._,:.~'.~-~--:~'.-.-.,,-,o,,-L·'~·---······""····"-··'~·__~·'0· SP GrahtellYls~n".le~ef·than .5%.isilt" S p·~':a-ae;uraE'cr;;:e1j'fVj~TFne:1Ea.jcla:rse:r·-. GP GW "eel!.... Cl>CoCDu..IQIa: 6 5 4 3 1 o CDZQ. lIJ>O-... Q."Ec all'llen C .c.2 0.«; 1IJ>QCD ~ ,.... -I 7 GW GM ~ 8 r- .... Boring'No.HD~j-Sheet _.J..-_of..1L_ j~EI ~(0. SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __2_of ...,.A- Date 3/28/83 Boring No HD83-43 (River C)Angle (from Horizontal)90 0 B Main DamFeature Bearing __-=;::;.:;~..,....,._ Coordinates:N 3226736.6 Date Started __3~/~14..-/:.-8-,-,3....,....._ E 745055.6 Date Completed _3...;.1_1_4..:.-/--'.8_3 _ Logged by RLT,MPB,BEH,lFB,!LEM,NBH Ground Elevation ----J..l'+.4o.6J.-l-.-J.-l-- Rock Elevation ----~1l,..,3J..Sl;j.,5J...-.7./---- Total Depth Ground-Water Elevation_--==~_ """I 1 -Remarks c .S! «i C CD E .5 '".E SW GM 12 11 ~-Ow Co ~u-Zc.::I::.ce!u.5!c:_Ill 41>>-OU):E 0lc.f:-Gl11)::1 -l-Ud 01>Soil Description,2l8 CGl Q.~Co c.o1lI-~...l!...Im.5 Ec CDu I%:Oal ..JGl 0:1lI iDa.II: 9 SC SM -'i 10 100 Boring No.HD83-Sheet ...;2~_of _4 __ 43 r~ SUS/TNA JO/NT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet -.3 _of 3 _ Date 3/28/83 Boring No HD83-43 Feature ----=E Main Dam Coordinates:N 3226736,8 E 745055,6 Core Sizes 1>11C Angle (from Horiwntal)__....::9...0L o _ Bearing Date Started __----=-3.:.,./..,..14..,-.:.,./8::-3,;:--_ Date Com pleted _...:.3-=-/_1~4-=-/_8_3 -- Total Depth 1 07 ,7 Ground Elevation 1461.1 Rock Elevation 1385.7 Overburden Thickness _6_5_,_4 _ Ground-Water Elevation_-_-_-_ Logged by BJL,MJ?B,~EH,JEB/I.EM,-r Graphic·Log c u ::li!.:0 ~C :c 0 !.a :l.c .2 >-l!!Q.0 ECl38'l!caa;0 :I a :I GI.....G1>'0 ti ~...l Classification and Physical Description q !E z E Remarksco!!::2 u:a::a::>C 2!:!!.:::i iii cJ cJ 0 "03 6 9 12 10 .= ..... Boring No.HD83-Sheet 3 43 01 4 SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet~of_L Date 3/28/83 -,, Boring No HD83-43 Angle (from Horizontal)90° Feature t Main Dam Bearing Coordinates:N 3226736 8 Date Started 3/14/83 E 745055 6 Date Completed 3/14{83 Core Sizes NX Total Depth 107.7 Ground Elevation J 461 J Rock Elevation 1385,7 Overburden Thickness --'"6'-"'5'--','--'4'--_ Ground-Water Elevation_-_-_-,--__ Logged by R II,sMPB.RER.IEB /I,EM s Graphic log cu:o!!~0 C :E a :;.c.c .2 >-m Q,E 'E0,'.g):;CII 0 ...~CII CII'"'0 ti Classification and Physical Description ql z E Remarks I""!!!ico!!=2 a:>C 2!!:!.::i Vj d 0 iiiII!-= ~ ! ., , , 1 - Boring No}lD83-Sheet 43 4 of 4 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of-L Date 3/28/83 ..... Boring No HD83-44 (River E)Angle (from Horizontal)----::.9....;:O_o Ground Elevation __-=-1->.•...:.4..=:S.::.9...!.•.::.9 _ Feature t;Main Dam Bearing Rock Elevation __--=1:....;.0...=3:....:9....::2"-'.:-4'--_ Coordinates:N 3226818.9 Date Started __----'3:::...<../=-1=.S<-/8.::.=3 Total Depth 118.0 E 745032 .9 Date Completed 3/16 /83 Ground-Water Elevation _-==-_ Logged by RI"r,MPB,REH,.IEP/LEM.,.NBH Remarks "51 'nit!Aiu -''\iJ,l-,ndr-!,-C:n~...\,:..,:;, -r ~H::~:~;~;ffiYf:I'-- G =2.81"~-j's--.........C'...•.••....-•••• C 02a; 'E CD E 2 0; ..5 Boring No.HD83-Sheet 1 of _4",-_ 44 Soil Description Gravel1j-SAND,S7~2%~claY-$ilt,, saturat~d,d~rk olive grey,Tmedium-·-fo-·-coarse.-~~·-~--_.L-....-"~'-7--'-~;+-'--'-"'" "0.ct!-CDCl,.Co cDC,)"'/CDa: 'E.=::Oll) 0 0 ~...oQliDa. 6 4 C.co2e..CD ,. 0411 §. ..-, 1 SWI""'" I l 2 SP 3 ~"._<,"r .-7 SP ~SW 8 OC/S ~ "Jill ~ SUS/TNA JOINT VENTURE sal L BORI NG LOG WATANA DEVELOPMENT Sheet_2_of ~ Date 3/28/83 Boring No HD83-44 (River E)Angle (from Horizontal)__--"9""'0'-o _ Feature I;Main Dam Bearing --=='--_ Coordinates:N 3226818:•.9 Date Started 3"'-'-I....l=.5L/:><8=.3 _ E __..745032.9 Date Completed __3",-,-,/1~6,u./,-,,8,-=3,--_ Logged by BLJ,MPB,BEH,IEP/.LE4NBH Ground Elevation __~1!,..f,q..1~5J,J9~i~9L---- Rock Elevation ---"""1,,,3~9f:.2~.o't~1 _ Total Depth 118.0 Ground-Water Elevation_==-_ 100 9 11 "l;l .ct'!-CDCl,.Co<DC-) ..Ill)a: Soil Description c ~as C <D Eg '".E Remarks Boring No.HD83-Sheet 2 44 of 4 ..- GEOLOGIC LOG WATANA DEVELOPMENT SUSITNA JOINT VENTURE Sheet.3...-of...4-_ Date 3/28/83 Boring No HD83-44 (River E)Angle (from Horizontal)90°....Feature --E Main Dam Bearing Coordinates:N 3226818.9 Date Started 3/15/83 E 745032.9 Date Completed 3/16/83 Core Sizes NX Total Depth 118 0 Ground Elevation 1459.9 Rock Elevation 1392 •4 Overburden Thickness __5L.7Lo...5.L-_ Ground-Water Elevation_-_-_-_ Logged by RLJ ,MPB,REH,JEP/LEM, NBH of 4BoringNo.HD83-Sheet 344 cu:::!!..!:c 0 Q) ..Q :!c.Q E1Il0 C..=CD <;l e:z e Remarks a:a:>C =.. 0 0 0 7;;1I3 .5 Classification and Physical Description Graphic Log 1----+30~~_.....-4.....-+-"--!±' 45°/ n•.~g~i 45°I Ii-----··I 45 °25:..I-."---,---'-r-,+--- 0°-/'1':1··········:.···.····,.0° 45°;( 45°:::::~-"--H 1g~-.;.:..:....__.::;·.··········11'··.+:-:..;'.,·:··'I'J--.J_:"'T·:_:'-!'~' _..:(77r.·.15..-,.9"q.~•.p;.iO,~is.e4Monzani~e ..gre nted8.0 45~<..,'e~~rse ;)~y,~no;;wrp];:q.k :lZ-#~1ii:i'~J!', ._-45 -.L.--:"";",,zorie :@ .I .•.....•.ia~L -....:.-······:rF:·::~~~,..,S.... 50°/-_.~...,.._,t--,'.L-.·Ck~~!ril!tod:~:7:,Q··o.5Did~tl1~O.3~Q':6'TSdih:Tlli~C1i:L ' 85 ..,78~1:'::.~:::~~~~:~~=~,.:sf:roq~,._.,_f_r~s1i:::::ir:!~,:~?,. 3,....,,:.'U',nstiained.:S 'w!:qaC03 'coat-+ 45°:(.ings..' 1-'-'-"'."'''--1 ~1~:~~~:,=-_·_~t;~i ; ".i ..•....L __)..-.•.....--.--j----~,,·-······t ..-...;.",~--f :J ;,-:;.~i,~JL._.,_,...r·r.:J..:::,_+_.~.__._•.....,,,_'-_ 8·,.D.tor';t .',1':.v,..o;";·',,;;;;.,4.......•".',","....,""e.a J;eo...ay .g.Li ay ."i. .Me:.'co,a:qsegJjained T5,~~O%111~fies J ""·~mar~~ocmase'F;'r~eslr:--::....::;-r:.=.r:J T~'r~- .•..·.g:n,;,,r,03·dlose]yto Toea]l1)':',intensely. ~,p.fraict ..L n:lax.::a:..:s.!':'_llli;n_,-=~,mos.tJ;.y_l.:... .•0.21-0.,3 HJrdI,!strg;fr ,lunsta;i,ned i "+_J.,..__·~.?~~I:::CI.~:3:::~j~,::~~~3i.9.-:~..~i_,1~r!i1,_ .Many meebariida.rTdw~hreakS ...'l ...... I SUSITNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet _4_of _4__ Date 3/28/83 Core Sizes _ Boring No HD83-44 (River E) Feature £Main Dam Coordinates:N 3226313.9 E 745032.9~------- """ J ~ I i Ground Elevation 1459 a Rock Elevation 1392.q Overburden Thickness -----.:::2).,Z~.",,...;5;)..----- Ground-Water Elevation _ Logged by RLJ.MPB.RElI,JEp/~ cu::.e.....2:c 0 CD 0;.cc-o E C«I 0...::l III RemarksC!e:z Ea:Ii l<2 U U 0 -11:1 l/I .5 Ang Ie (from Horizontal)90 0 Bearing Date Started 3/15/33 Date Completed ----.3~,f-/l!-96+/e8_,33~---- Total Depth 118 0 Classification and Physical Description !! ::l .2 8'U ~...J 2 ~ U)3 6 9 12 Graphic Log >-CIo '0 -=::::i Boring No.HD83 -SheeL__4_of-.::!4__.44 ...-._t SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of--3.- Date ~28/83 SUS/TNA JO/NT VENTURE Boring No HD83-45 Angle (from Horizontal)45" Feature £Dam.Right Abutment Bearing 328"Right Abutment Coordinates:N 3226933.2 Date Started 3/16/83 E 745003.6 Date Completed .......:::3...t../..:.1.:...7!.../8=..::3~_ Logged by NBH •MER •.rEP,REB hEM,DAF Ground Elevat i on _----=1-".'-,4-::6:-::3,...•.....,5".--_ Rock Elevation 1--0.-'4-:2~3=--.9:;;---c:;:;-:-~-'- Total Depth 80 •0 Ft. Ground-Water Elevation _ Alte~bard &eas Drillin.g.42;...47 ·TI~ ····Water ..raturn..@. 47 Ft •. c ~ '"'E ~Remarks 2 Uj .5 GP S~n.dy GRAVElf,.5.l.12%sh t •wet. GM._.._Q.liv.et-lSub:tQund-'~4 •..f.!J,lg~t().~Q~.'J:'~_g.2_... occasional eobble... SW 8M I--.---,~.,_--..,---..J.~-_h ..---.~.~-_+-..:....;...._..._c..~~..__1 8W 8M 1=_.:~d.al:tk.~.QJlj,Y_EL.;g:!:L~)!~LU~:¥n.ELl!;p.:.:.lc_q§1:.!'~~.il_.~..J GM6 5 7 9 8 ..... c ~-oll)'E.'0sgQI-Zo.:::1=J:f!u-'"_C 0.>QI>O 0",-QI i:0I0.",11:I:::1 Sa;-I-o·01>0.0 Soil DescriptionlI»01 0 0.'0 0 Coco!!",-iii:...:!...l~ __0 en.5 Ec Qlu !!!:!.a:~G1 oll)...lll)CJiijo.a: r- 1 GW 2 GM 3 "'"' 4 GW r-GM I 1'""". .- Boring No.HD83-Sheet 1 of 345----'-- SOIL BORING LOG WATANA DEVELOPMENT Sheet _2_of ....3....- Date 3/28/83 SUSITNA JOINT VENTURE Boring No c.HD83-45 ..Angle (from Horizontal)',....".-__4..:....::..5_o _ Feature .t:.Dam -R~ght Abutment Bearing ....;3:-:2:;..:8~....,-;:;:"-=----_ Coordinates:N 3226933.2 Date Started 3/16/83 E 745003.6 Date Completed 3/17/83 Logged by NBH,MPB,JEP,REH/LEM,DAF Ground Elevation __~1,....4..-:-6~3_'.,.5 _ Rock Elevation 1.-:4_2.;3~.~9--=---=--_ Total Depth 80.0 Ft. Ground-Water Elevation __==-_ iI:_ci ~'E.'l:i/11-ZQ,:I'::.t::.!!u·.!ac _IIIQ,>~>o Ow -e>:Coa:l:l ElD -l-°ci 0»Q,o Soil Description.!:!IS ",-Q.'tj iI:..Co l!...!en.5 Ec ~ua:~'"oe>...Ie>0iiiQ.a: 11 c .2 '; C <IIe 2 iii .5 Remarks .., ..3 "'""I ! - Boring NO.lID83 Sheet 2 45 01_3- SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet ----3 __of ~ Date 3/28/83 -i .Boring No e _-JI:=D:;:8:;:3~-_4,-=5,--~_ Feature ~Dam-Right Abutm~t Coordinates:N 3226933.2 E .745003.6 Core Sizes NX Angle (from Horizontal)__-=4...S_o _ Bearing 328 Date Started __~3oL,ll-l",-,61L1-'!8>L..L3~_ Date Completed _...3-1-!.....1.L7-J-1....S-'3'--_ Total Depth 80.a ft Ground Elevation --~1....4'-l,;6l.;3,---5_--- Rock Elevation ----Jl-"4""2:..3~9;1----­ Overburden Thickness 38.9 (vert) Ground-Water Elevation _ Logged by NBB,JEP ,MPH,REH!J.f.Y.-_ o-o c Q ::t.....2:c 0 CD a;.aQ.C E Cl!!0 ::I al (;J e z E Remarks ci ci )(2 0 0 0 'liilllI.E Classification and Physical Description IO. C .co2a; CD>Cal !! Graphic Log - i' - - Boring NoHD83-Sheet ----3_of 3 45 SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of ---L... Date 3/28/83 SUSfTNA JOINT VENTURE Boring No HD83-46 Angle (from Horizontal)__----'4::e-5""--o Ground Elevation _-,1~,4=6=.1 .=.5 _ Feature £Dam Bearing 155 Rock Elevation __....1...,.=I4~0u.6 0~_ Coordinates:N 3226614.7 Date Started __---=3:.L/~1c.:.7..!../,.:::8..:::3~Total Depth 98.2 FT. E 795075.3 Date Completed 3/18/83 Ground·Water Elevation---===---_ Logged by NBH,MPB,IEP,REH!T,EM,DAF at ....fl;;~·'jJ)t1~f,~~~:!f£I ...... Remarks ·..·~t~i;~~~ I 5~0'-H~iC]j;'-. . . ._....+...,.-......,....,._....~~.~....!....\ Boring:No.HD83-Sheet _-=1_of 3 46 GP GM GP GM 9 7 8 c :c °CD 'E.".co2 0-CD-za.~=.c!u_ClI a:a;_c a.c:CD>-OLD -CD :E ClI:D~EIIl -l-Ud 0>a.0 Soil DescriptionIll>.218 a."Coc.!!ClI-Ec :c ...CDu l!..J IX:(1).5 OCD ..Jill CJ!:!:!.tIIl'lJ iDa.(I)a: 1 r-GW 2 GM ~ 3-4 OR 5'SM 6 -10 SP -11 - ..... - - SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet __2_of ....3.......:- Date 3/28/83 Boring No HD83-46 Angle (from Horizontal)__~_2.4=!.5_o__ C 155 0FeatureLDamBearing Coordinates:N 3226614,7 Date Started 3LJ~lu7'-'/t..l8.1...3L__ E 795075,3 Date Completed _---'3l.l./....J.l.I.8./.-!8l,L3.L.-_ Logged by NBH.MPB.JEP,REH/LEM,DAF Ground Elevation 1461.5 Rock Elevation 1406.0 Total Depth 98.2 it. Ground-Water Elevation_-_-_-_- Remarks HD83-Sh 2 3BoringNo.eet of _ 40 C J_°G 'E."tI =~oD-zQ.:1=~l!!u.2c _(II oil):EC,l11:I:1 Q.C;G>--111CI.(II .218 E1II _l-Ud Cl ..0.0 Soil DescriptionoD..0."tI CoCallI\-E c J ..oDo l!!....1 !:!:!.II:(/)..: (lllI\ooD ....1111 Cl (/)ma.a:: - -GEOLOGIC LOG WATANA DEVELOPMENT Sheet ---3 _of --3.- Date 3/28/83 SUS/TNA JO/NT VENTURE Boring No HD83-46 Angle (from Horizontal)...4...SLo _ CFeature__Tl.>--DLlCI.amllL-Bearing 155 0 Coordinates:N -~3t22~Ge6±144......+7----Date Started ------,3M-1±-1+7+/~8_63--;--­ E --71-9::J.,5..IJOI.l-71--.5.J...-..3~---Date Completed ---"::,3~!l~8;),1r:=8;l-,3~-- Core Sizes NX Total Depth 98'.2 'Ft. Ground Elevation 1461 . 5 Rock Elevation 1406.0 Overburden Thickness 37 8 (nert) Ground-Water Elevation _ Logged by NBH •MPB •JEP •REM ILEM.DAl Graphic Log cu;{!,Q;.5!C :c 0 OJlD~.c.2 >-f ..CI.Q E C.....a;;Cl :::l .;!g'lI:I a0~:::l lD lD>'0 U ~....Classification and Physical Description !E z E RemarksQ~:::::l ..Ii Ii :::l !:!!...u..x .. ::::i en c.;i c.;i 0 'lD3 6 9 12 lXI .5 -, - ~ I Boring No.HD83-Sheet _3__of _3__ 46 SOIL BORING LOG WATANA DEVELOPMENT Sheet __1_of __2_ Date 4/11/83 Angle (from Horizontal)45 0 Ground Elevation 1 ,459 •6 010 0Bearing Rock Elevation _ Date Started __---=-3"'-;-/..:.1.:;..8!.,-/8;:-3:::.-Total Depth 65.a Date Completed 3/19/83 Ground-Water Elevation _ MPB/T.EM Boring No HD83-47 Feature DIs Cofferdam Coordinates:N --:3:...:2:-:;2::..,7'""'0"""3:-:;3c-4:...,O;-_ E __74-:3_0-=-9--'...4.:.....6:.....-_ Logged by rEp,REB,NBB, ,.... ;..~----. 1 .?~_:l-i-+"~._-~;---\·~.__.._.~~J.-~-..~,:.~--.~~"-~.~'i-..-'-.-H.-.~~~.~-.:~_._.:L ..._.H_.,.;__~0 1 ! r ~.- i!,-"..1 .•.•..'j}to-r-eTfine;-t'o-nn~dttImrg-a:ndt-----~-+·--+-----.---.---_...~"----L,-.-.".._;-j ".-,'1 '"-"',-_-i --i t··1"· _C'i__i __-:J:~:'--'!,---i-e,-~"L '=-__L:__;--+-GraYellJ:~f_ND~;less,thanj 5%....sift:".''satufat¢d~Tdat~cbliire gr~y-,__:fine!to ....! -co 1l r fe,-!f*pr{,-~tiae-a;.tO~su1J'an.gutarL grave O~~ae-onaf··,··:~?b~l~~~--L-~--!·...~~ET,~-_=J,----~.-- >_t'··"'1 L¢ss Ifinel san~~, "1.,_._._;~~.,.L_._L-~~_<_v_LL,"_"._!.__i_~,"J.__~~ GW GM SP SP SM GW 6 9 3 7 5 4 c C OlD 'E..2 ~"C -;.c .2 -lD-ZOo ::::I::.c!u0-_Ill 0 10 'E'Q:;_C o.e Gl>O -Gl :SCI111::::1 EGl -I-(,).CI>0.0 Soil Description Gl RemarksGl>.218 0."C 0 Co Eco!!Ill-~-Glu e...l a::11).5 Ec OGl ...IGl 0 2!:!:!.III III II)iDo.a::U; .5 1 GM 2 SM r r Boring No.HD83-Sheet 1 of 247-~----- SOIL BORING LOG WATANADEVELOPMENT Sheet _2_of _2_ Date 4/11/83 45 0BoringNoHD83-47 Angle (from Horizontal)...:....,._ 1 0106FeatureD S Cofferdam Bearing _ Coordinates:N 3227033 0 Date Started __---.:3=-/~18~78~3----- E 743094 6 Date Completed _--=3:....1.=1..:..9:..../8..:...=3 -,-- Logged by JEP,REH.NIH!,MPB--.4.EM C it_°III E·"0 .c .2 1Il-z~~=.c!u.2c _l'lIali~~CD>-011)-Ill :Eom:::l EclI -I-uc:i C1:--~o Soil DescriptionCD:--.218 ~"O CoO..!!!l'lI-Ec it ...GJu l!..1 !!!.II:lIJ":l'lIl'lI o III ..JCD 0 lIJ iii~a: GW GM Ground Elevation 1459.6 Rock Elevation _----===----_ Total Depth 65.a Ft. Ground-Water Elevation _ Remarks Nojrecovery!Erom 50t-60 i ft .•Pipe---1>Iock.~d~.-'--"..,. ~~.J.-o~H_~~"4~","__ G()f'ebarrelwon't "go!dOWl:!Lthrotlgb 2BoringNo.Hfl83'Sheet _.-:2=--_of47 --- Ir- SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of JL- Date 4 I 11 183 Boring No HD83-48 (River G6)Angle (from Horizontal),__--=<-9,::oO_o _ Feature Bearing Coordinates:N 3226951.3 Date Started -=3!.J.I-'1"-'9!.J.I'-'8~3o!..-_ E 742833.4 Date Completed _-----"3'-L/-=1.::..9.L../8:::.;3~_ Logged by :tiWR •MPB •B Eli.lEP II.EM.DAP Ground Elevation 1,4 55.6 Rock Elevation _ Total Depth 108 .0 Ft. Ground-Water Elevation_-_-_-_ GW GW.S,a~dYG~VE~4:tes~t:haIl.5%.Silt, satJurat~d"b]Jack,LlsuEr9unde~to· --LsuElangu1jar;:-:;fjIn~.....rff6-·Qoar-s·er:_r-,.-)-~ c -j ,..;,-..."....•:.-..."1-;''''''r-r-""":'1",,--; ,.-:+-r~t-~.Jc.-=..,.·f-;L-~·~~!--:·~-···-r--;···-· SP 7 6 5 2 4 3 1 c C ci CD 1:.0 ~"CI :::: ..c .2 o-lD-ZOo ~=..c!u 1!I_c _Ill CD"0.":Eo 1:ac;ID~o.e:-CD ECD -l-e.,).0>0.0 Soil Description CD RemarksCD>.218 0."CI Cl Co Er-oo!!Ill-Ec ~...CDu !!...I l!!-ee en.5 llIID OCD ..I CD t:l 2 en mOo ee 'Zi .5 ..... Boring No.HD83-Sheet 1 48 of 4 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2 _of_4_ Date 4/11/83 Boring No RD83-48 (River GG)Angle (from Horizontal)__-..:9;....;0:.....o Ground Elevation 1,455.6 Feature Bearing ;;:;.;;==--,--_____Rock Elevation -===--,--_ Coordinates:N 3226951 3 Date Started 3/19/83 Total Depth 108.0 E 742833 4 Date Completed 3/19/83 Ground-Water Elevation-===-_ Logged by NEB j MPB •:R Ell.lEE /LEM,DAF Remarks -~Jg~~«ffJ:i:m r..:L 2 7i P,L 181':I 9 .-Gh c: .2a; C III E 2 iii .E GP GC GC SP9 15 14 13 12 11 10 C :t °111 'C.'e .cO o-eD-Zc.~=.c!u a.~_c _<1:1 CD>-0ll'l :2 C1lIn::!c.t -III EeD -....0g 1:»>c.o Soil DescriptionIII'".2'8 Q.-g Coco!!<1:1-:t ..ll!.....IC/).E Ec eDu ~a::<1:1<1:1 OCD .....leD 0 (/)iDQ.a:: 8 Boring No.RD83-Sheet 48 2 of -----'04,,--,,- GEOLOGIC LOG WATANA DEVELOPMENT Sheet -----3.-of--.ll~ Date 4 III 183 SUSITNA JOINT VENTURE Boring No ~H;,;;;;D-,,8..::3,--_4,-8 _ Feature Coordinates:N ---;3hi2,"",2r106~9~5l-Jl~......3_--- E --+7t"'12....S~3;l-03h.'"'"'41----- Core Sizes ....NX..u>o._ Angle (from Horizontal)_~9,-,0,,-o _ Bearing Date Started __,....3'-/..1 1 9 1....8<-3'--_ Date Completed _'3.L/-/1 9.s-1""'8...3 _ Total Depth )08.0 Ground Elevation 1455.6 Rock Elevation ----------:c---- Overburden Thickness _-...:8:.::0:.;.:..:0:...-_ Ground-Water Elevation-=-:=-=.=-=--_ Logged by NBH,MPB,REH,JEP/LEM,DAF Graphic Log 3 of 4BoringNo.HD83-Sheet 48 cu~....2:c Q 41 -;.ac.c E Cl!a ~G>Classification and Physical Description <;I !!:z E Remarks Ii Ii ><:::J.. (,)(,)0 at1XI.s 88~r03 Diorite ,Slightly altered. ,.....Itl.··g:tay:med:grainec '.;jAltetnatiJig ..t~.if~~~gl~::E94=~tlJ~ L l,'(L05Hrd strg 'CqCOlh:~ald f:t ..:J_~:=,j4;:2a,IciJfHtty.l:dmo&lf~i-~~1·S i........'.]J •.5 ~...niin .,q.lmqstIY!UAUuiny! ,i'.'.,nealeq'fracts.ltardstrong 98-103 ~~TT······cro~se]y·]rr~ct.····max:-·O.~6',···minT6.1-'r-: Hard'strong ~,}.! ;,:100 C !.c .2 >-G> Cl ...Elf0.1;;~0 U41>Ci g-/CO!!~-=..u:!!!.::::i U) 3 6 9 12 r r ,- I I .... .... ,.... - SUS/TNA JOINT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet _4 __of _4 _ Date 4/11/83 Boring No HD83-48 Angle (from Horizontal)90 0 Ground Elevation __-"-14::!:dSdS.->-.""6'-_ Feature Bearing Rock Elevation _-""~~_ Coordinates:N 3226951.3 Date Started 3/19/83 Overburden Thickness _-,8~O\L..L'0"'--_ E 742833.4 Date Completed _3"'-'--/"'-1~9.L./_"'8"'3'___Ground-Water Elevation...l-=-"'-_ Core Sizes ~NX~Total Depth 108.0 Logged by NBH.MPB.REH.JEP/LEM.DAF !I!I!!! Graphic Log Classification and Physical Description c .S! ta C CD E 2.. -= Remarks , -.~ Boring NoBD83-Sheet 4 I.Q of_4.-- r .l 2.2 RELICT CHANNEL BORING LOGS ~-"- SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_1 _of_S_ Date 1/28/83 Boring No Water Well Feature Watana Base Camp Coordinates:N ---===--_ E--===--_ Logged by lEI?,1mB ILEM 90 °Angle (from Horizontal)__~,,----_ Bearing ---===--_ Date Started 1?/y2~8O_,/~8:'-':3~-- Date Completed __.------:1"-'/:...:3:..:1"-'/:...:8:...:3=---__ Ground Elevation 2267 0 (ApprQx.) Rock Elevation 2060.5 (Approx.) Total Depth 214 •5 Ground-Water Elevation...:-;::.:-;::.:-;;;;....-_ of __S,-- Remarks Boring No.Water Sheet 1 Well Soil Description 8M 8M 8M 8M 8M 8M 9 2 S 4 3 1 10 c lc 01\)c."CI .c.S!GI-ZQ.:I::.cl!!u·_Ill ~r:Oil)ig'a.,;Q.i:-GIlD:I SGI °0 01>GI·>.218 Q."CI CoQ~1lI-Sc ·11 ..Glu l!...I !!!.a::(1).5 Illlll oGi ...IGI CJ (I)iiQ.a:: 6 8M- 7 8M..-8C ~8M8SC ,.... - SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of_5 _ Date 1/29/83 ~ r 2267 0 (Approx) 2090.5 (\pprox.)214. Boring No Water Well Feature Watana Base Camp Coordinates:N __-"-_ E---:=_ Logged by JEP,WMB/LEM 90°Angle (from Horizontal)_----':o..:::.._ Bearing Date Started .=.1L../",-29=-1,--,8,,-=3~_ Date Completed _~1..../L.:3~1,,-,/~8::C.:3~_ Ground Elevation Rock Elevation Total Depth Ground-Water Elevation_-_-_-_ - of 5.WaterBormgNo.Sheet 2 19 17 15 16 """1 12 - 13 - 14 c C ~cl lll 'E.'tl ~ .c.2 o-lD-Za.:::I:.cl!!Col IU_c _II! lII>-0(;1):Eel C--a.i::-lila.ca 11:I:1 ECiI -~°0 Q>a.o Soil Description CD RemarksII>.2'8 a.Co E -Q.!!!Il!-E~~...ClIO l'!!.... a:rn.5 OCII ....CiI 0 2!!!.calli iDa.1;;II)a: .E 11 ~ SUSITNA JOINT VENTURE SOIL BORING LOG Sheet _3__of_5_ Date 1/29/83 2267.0 (Approx.) 2060.5 (Approx.) 214.5 Boring No Water Well Feature Watana Base Camp Coordinates:N ...:-::-=-=--_ E --- Logged by JEP,WMB ILEM 90°Angle (from Horizontall Ground Elevation Bearing Rock Elevation Date Started ---:'1..:..,/,;::2-::-8..:..,/;::8-::3,...---Total Depth Date Completed 1/31/83 Ground-Water Elevation-_-_-_ Boring No.wa t er Sheet _....3'---_of __5J-_ 3M 3M 3M CL 3M GP GM GM GM 25 26 28 27 23 22 24 21 20 c C ~°CD "C.-u .S! .s::.S!0-CD-Za.=':.s::!!g «i _C _IV CD'""011):Cat C--a.e -ua.",ID='Su -~(,)0 at>a.o Soil Description u RemarksCD>.218 a.-u Co EQ,!!"'-~..l!...l(/).5 Ec Ug S!!!.a:GI'"OCD ...lCD ~ (/)iDa.a:<II .E -- .... SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_4_of_5_ Date 1130/83 - - - - - ., Remarks 2267.0 (Approx.) 2060.5 (Approx.) 2]4 5 Ground Elevation Rock Elevation Total Depth Ground-Water Elevation--===--_ Soil Description Angle (from Horizontall -",9...,,0,-o _ Bearing Date Started 1 12.><.8 /8""3""---_ Date Completed __1/ 3 1-4-/8....3'---_ """I CL ML ., SM -., GM IIO'I!; =-~-°Gl 'E.'0 ..coS!GI-Za;==~!Col.5!c _ca 1iI>-0 10 :Ct»--Q,i:-lDQ.lIl 111=SGl -t-°o 1:11>0.0iii>.2'8 Q,"l:i CoC,!!.-Ec il-lDu l!!..1 a:C/).5 oGl ..IGl 0!:!!.lIltll iiiQ.C/)a: Boring No Water Well Feature Water Base Camp Coordinates:N _-===----'-__ E _==-_ Logged by .TEP,WMB IT.EM Boring No.Water Sheet_........4_of __5L-_ Well ... SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_5_of_5_ Date 1/31/83 (Approx.) (Approx.) 2267.0 2060 5 214.5 Ground Elevation Rock Elevation Total Depth Ground-Water Elevation_-_-_-_ 90°Angle (from Horizontal)i :.....:._ Bearing ~-=-=,..._;_:~--_-- Date Started __---::1;.:.,/.::2~8~/~83::......_ Date Completed _........::..1:..../3::,.1::,./:....8::-3=---_ Boring No Water Well Feature Watana Base Camp Coordinates:N _ E _ Logged by ,IEP ,WMB IT.EM .- = C :l °CD 'E.'a .2 .c.2 0-CD-za.==.c!u Gi_ca 'Eaai-=a.i:CD>-001)-CD :Eo11I=SCD -I-Q.0>CLo Soil Description CII Remarks....CII>.218 Q,'a 0 Co SQ,!!ca-:l ...l!....en':E c CDu .5l:!:!.a::~1II .28,....CD <:I III II:III.: ,,... 44 .WaterBOringNo.Sheet _"",5 __o"_~5,,-'_ Well SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of 7 Date -----:sT25/83- - SUS/TNA JOINT VENTURE Boring No HD83-1 Angle (from Horizontal)----'9~O,!...o _ Feature Relict Channel Bearing -"~~_ Coordinates:N 3231536.1 Date Started __-..,2'-'-/-.=4"-'/--'8<..:3"--_ E 746996.6 Date Completed ---.21L8"-L..:/8"'-'3""---_ Logged by WMB,E.JK.REH,JEP.NBH/LEM Ground Elevation 2.246.2 Rock Elevation ---=-..1>--_ Total Depth 328.0 Ground-Water Elevation ~ c ~0<1)'E."C .:.2 <1)-Zc.::l=.:e!l,)0-_lIS Q.«; _c 0.>QI>O 0lt:l -QI :E tIlaJ::l E :u -l-ud til>C.o Soil Descriptional>.218 c."C c 0 o~lIS-Ec ~"-all,)l!-I !!:!.c::11).5 lIS lIS 0<1)-1<1)"Ul inC.c:: Remarks MC 9% 5!:i0 -HAM,CI .[0 &j~i1!~~{~\r'01 [ct}!;~i:mHJ;101 LL18 PLl3 PI5 ML-CL Silty,gravelly SAND,moist,olive brown.finet().coarse~sub angular to sub rounded gravel. Damp.den.se. SM1 2SS 12421917 ,..... 15 ""'".j.l..... Clayey,silty SAND,15-20%fine a 3 M SM graveL Damp,dark sub~N "....gray,a rounded,fine to occasional .j.lcoarse, (jj cobbles...0a-Hp., M More gravel.Cll 5~S 1 100 / coarse S H.5"SM (jj ,.c: Very dense.E-i 6 SM More silty clay,less gravel. SC-35 7 COBBLE/BOULDER TO 38.5 FT. ~8SS 10nt .5" 40 ,.....Striations on gravel. !!5 87 9 More sand,cobbles. r""""Striations. .....50 Boring No.HD83-1Sheet ---'1'----_of ~__ (~(ff) SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_01_7_ Date 3/25/83 328.0 /"90 0 46BoringNoHD83-1 Angle (Irom Horizontal)Ground Elevation _---=2:...;,L:2=--.:....::=-.:.:..::2:.-..._ Feature ReJ jet Channel Bearing Rock Elevation ==-_ Coordinates:N 3231536.1 Date Started __~2=.J./~4!..J/~8e..:.3~Total Depth E 746996.6 Date Completed 2/8/83 Ground-Water Elevation~==--_ Loggedby WMB,EJK,REH,JEP,NBH/LEM lI!!!l .! I J -I -'i , ~:~:i:i~:f:::;V/41 NP ~::::::::<WJ21.:.~.::..:::. LL24 PL14 PIlO CL LL42 PL18 PI24 CL M/C 12% ~Y\::Y~!;{{(~~:;Vi1 M/C 11% I;Q);::;::.;;·nfZ0J Clayey SAND,15~20%gravel.Gray, fine to medium. Subrounded to subangular gravel, striations on gravel. Very dense. Moist.more gravel. Damp. Silty SAND,20-25%gravel Humid,dark gray. Fine to coarse. Subangular gravel.striated, occasional cobble. Dry,more gravel. Very dense. Less gravel. Less silt,more gravel, noticeable mica. SM SM SM SM SC 8M SC SC SC SM SM C C ci Ql 'E..S!~-"C <;i.c .S!Ql-ZOo :I;.cl!?0_lU OU')Co.cu _C 0.>Ql>O -Ql :E OlIEI:I EG;-l-Oci Ol>0.0 Soil Description Ql RemarksQl>Olo lU-Q."C 3:"-Co ~...I EiO~.-°til":E C Qlo 2a:OQl ...IQl Cl'!:!:!.lUlU jijQ.(ijIf)a:50 E 10 SM Less sand and gravel.moist. NP 100 Boring No.HD83 ..J-Sheet 2 01_-,7_ p..... -~~fr ~~l@ SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT ----. Sheet_3_of_7_ Date 2/2S/83 Boring No HD83-1 Angle (from Horizontal),__~9~O_c _ Feature Relict Channel Bearing _ Coordinates:N 3231S36.1 Date Started --'2"-'/L.:4:!.../~8=.c3~_ E 746996.6 Date Completed _~2~/1~8,,-,/~8,L,3L-_ Logged by 1-JMB,RIK ,REB,JEP •NEB ILEM Ground Elevation 2,246.2 Rock Elevation Total Depth 328.0 Ground-Water Elevation_--'-,..._-~ COBBLE/BOULDER SM Silty gravelly SAND, DanlP • C 3:oQl 'E."t:I ..c.2 0-(1)-ZOo ::1=..c!-«I 011>at;_c 0.'"(I)""-QIll:l::l E~_l-e).01", QI '".218 Q."t:I 0 Co I"'"c..!!!«1-3:..(l)u11).5 E Cwa::«1«1 OQl ...IQI 100 II)jjjQ.a:: 21 ~ S- u :COl 0.0 «1...1o Soil Description c .S! (;j 'E QI E 2 iii .5 Remarks g<:i:n~~.~~.~:~::~ LL17 PLlS PI2 ML M/C 3% fli:¥:ij)\·tJ7hj NP ~~!~j;wtA~' LL17 PLl5 PI2 MLM/C 4% f1r':L:r=",~ NP M/C S% ~t]}{~.(()/f/h1 Defective pipe bandoned-hole-@ 117.0 S~0 -C8R,BB Redrill twice ffi¥~?f!!;;:;~!B~ LL19 PL14 PIS ML ....CL M/C'::S% Ri~~::~:;~~~mi~l LL2Q PL14 PI6 ML-CL ~ M/C 6%--i W\iWf:'(i;}?~ LL18 PL16 PI2 ML M/e 3% Boring No.~lD~~-!Sheet -3--of ------:J- More gravel • SM Dry 8M Less gravel,striations. SM Less gravel SM SM More gravel. 22 23 r-ua .-. I 11.S ~ 0 r- 26 8M Clayey,silty SAND,5-10%fine SC gravel,moist',dark grey-fine to coarse, occasional cobble. SM SC I"'" -8M Slightly less clay. fJOl~JtlI~~JE:1fJJ :~~ SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 4 of 7 Date ~5/8~ Boring No HD83-1 Angle (from Horizontall __--=-9..::c0_o _ Feature Relict Channel Bearing _ Coordinates:N 3231536.1 Date Started -----'2"'-/<-4-'--'--'/8=3 _ E 746996.6 Date Completed __=:.2LI.=.:18"'-'---/8"'-'3"'"'--_ Logged by WME,EJK,RER,JEP ,limll/LEM Ground Elevation 2.246.2 Rock Elevation =-=-_ Total Depth 328.0 Ground-Water Elevation -=-=..:-=..:-=---_ I: C 3:ci 01 'E ."C .2 ..c .2 0-01-ZOo ::I:::.;C!CJ 0;-..o It'>Cc.:;_I:0.>0)>--01 :COl1Il::l E Q;-I-(.)ci 01>0.0 Soil Description 01 Remarks01>.~8 Q.-c Co Eo..!..-e c:3:...01 CJ 1!!...J W c:CIl1:....o Qj ...JQj 0 .5 150 CIl ijiQ.c:'"1: 30 200 31 32 33 34 35 36 37 SM SM SM SM 8M COBBLE/BOULDER 158.0 ~164.0 FT. More gravel~subangular to subrounded Laminated silt clumps. Less gravel. COBBLE/BOULDER Dry. Silty SAND,10-15%fine gravel.Dry, olive gray,.fine to coarse. More gravel,moist,subrounded Silty,gravelly SAND. More gravel,subrounded. WET 191-194.0 FT. Less gravel,more fine to coarse sand Laminated silt clumps? l¥i'o~~j@fli}jfWd NP M/C 3% WATER LEVEL @ 165.0 Ft. 2/16/83 M/C 3% M/C 1% {jii~;\~K:}~eiHltl M/C 1% ~£1Q;ff{f~W!ii;t~ NP Mle 2% Ro:q'6tiiiilHrA~ M/c 3% ~·~:Y'j.i!iw.:g.~::·4~ NP ~ :1 -.1 """'II Boring No.HD8 3=-lSheet ---,,41<--of ----1....-- rmJjlMlli ~lEfJJ~~f~~ SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 5 of _7_ Date 3!25/83 Boring No HD83-1 Angle (from Horizontal},-.::9~O=__o _ Feature Rei ic t Channel Bearing Coordinates:N 3231536.1 Date Started =-2.L1.::::':4.L/.::!8.;d.3 _ E 746996.6 Date Completed __--=2.L/~1::::..8.L1::::..8=.3 _ Logged by ~,EJK,REE.,JEJ?,NBH/LEM Ground Elevation 2,246.2 Rock Elevation ==-~_ Total Depth 328.0 Ground-Water Elevation-=-==--_ c ;::o lU E .'a .c .2 0-lU-Zo.=::.c~y_Ill 0.,Cii _c 0.>ell>-0",-lU =CIl:D=E Qi -~0 0 CI>0.0 Soil DescriptionlU>Cl O o.~Coc~._0 ",-E C ;::...lUt.)f!..J W a:II)..!:"''''OlU ..Jell CI 200 II)mo.a: .... .... .... 2Q5 210 2~5 2:?0 225 ;30 240 250 38 39 40 41 SM SM SM SM "S"G Silty SA~n,15-20%fine.gravel,sat- urated.,very;d.ark gray,fine to coarse,subrounded to round'ed gravel. Well grad.ed SAND,20-25%fine to coarse grav.el.5-12%.clayey silt. Sabiiated,olive 'gray. .Finetufcuarse. Silty SAND,10-15%coarse gravel, saturat.ed,olive gray,fin~to medium. Clayey,silty SAND 20-25%fine to coarse gravel,wet, olive gray,fine to medium,trace coarse rounded to subrounded gravel striations and polished. Remarks No recovery, material coming up return pipe when adding sec- tion.Plugged. Tried: CSR,OB;HA..'1,CI PNEUMATIC PIEZOMETER P @ 225.0 Ft. ~1~;gr.\:~:.:!.q:~g NP At 225 Ft.,very easy drilling,.t by weight of rods e~:t::;-.'.::::::;~.DT;:;:;;:::':' LL20 PL16 PI4 ML-CL 2%ORGANICS Boring No.HD83-1Sheet 5 0'_--,7_ !~@ SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _6_of _7_ Date 3/25/83 Boring No lID83-1 Angle (from Horizontal),__---:!.9~0'__o _ Feature Relict Channel Bearing _ Coordinates:N 3231536.1 Date Started __~2!:..L:./4~/L8~3~_ E 746996.6 Date Completed _~2Lllo.1~8LI8~3~_ Logged by WMB,EIK,BEH,IEP,NBH!LEM Ground Elevation 2.246.2 Rock Elevation _ Total Depth 328.0 Ground-Water Elevation_-_-_-_ e: C-o ""'E..2:1:_"0;.cB ""-Zo.j=..&::~UBe:_<II ",,=--0U>~tIl C0.-;o.t:-""lDj E""-I-uci til>0.0 Soil Description ""Remarks"">.218 0.'0 Co EC""ca-3:...""u ~...Ien':Ee:j 0I!!l!!jjj a::0""...I""0 .::: 250 ~<II ijio.a::l/l .E 42 43 44 45 CL SC SC CL CLAY •.10-15%fine gravel,2.0-25% fine to coarse sand.Damp,olive gray,trace organic. Clayey SAND,.20-25%gravel,damp, dark gray,fiine to coarse,Angular 'to suDa.ligularg.ravel~ Varved silt clumps,trace organics. Less gravel,more clay. CLAY,less than 5%gravel. 5-10%fine to medium sand, Moist,olive gray. Medium stiff. ~M.u~ LL26 PL18 PI8 CL MIG 13% P;DAW!ff~ LL31 PLU PIl4 CL MIG 9% ~~%·:'::;,:'.:.:=1 .Drg . M/c 18% ~" MIG 23% 1 Boring No.lID8 3-!sheet __6_of __7_ 280 285 290 295 300 46 47 CL ML CL CL GM GM Less than 5%sand,dark grav. Laminated silt clumps. Varved silt clumps? Laminated silt clumps. BOULDER. Silty,sandy,GRAVEL Dry,olive gray. Sub rounded to fine to coarse, oxidation on surface of gravel. [;;·:·<:~?i~:;'-:;:NLH!d LL25 PL20 PI5 CL-ML M/C 21% fil;iiUiFi!!jF6;1~~1 LL31 PL22 PI9 GL M/c 24% a~>jU~:)Ji;=i'!lY!!61 LL29 PL22 PI? CL M/c 22%. t5tP3HW~~:J%02 Hard Drilling rr SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _2_of _7_ Date ..... Boring No RDS 3-1 Angle (from Horizontal)9:::...0:::.-o Ground Elevation 2,246.2 Feature Relict Channel Bearing Rock Elevation ~ Coordinates:N 3231536.1 Date Started _...f2d/-",4~/c-'8~3L-Total Depth 328.° E 746996.6 Date Completed 2/8/83 Ground-Water Elevation_-_-_-_ Logged by WMB,E.IK,REB,,rEp,NEB ILEM I: C ;:ci u 'E.".9 .c .9 0-CII-Zo.::::I::.c!u ;; _I:_<'lI u>-011):E CI Ca.t;113::::1 0.>-C11Et-l-Ud CI>CII CII >.218 0."I:0 0.0 Soil Description E Remarks o..2!<'li-E I:;:..CIIu ~....I a:en':OCII ....ICII <:3 .sw<'lI <'lI aio.300 en a:II>c: - -p.,05 r-l-10 L1J.5 _. ..120 ~Jl.-52-53-54-55-56-57 _. \Or GM GP GM GP GM GP GW SW .Sandy GRAVEL..,;.:5-12%silt,Olive gray • fine to coars~with COBBLES,sub~ rounded graveL Less sand,fine to medium,olive brown. "More saUd;"sti.:broUri.ded to'subangular gravel. Less silt,. rounded to subrounded gravel. More sand. More sand. CSR,·TC w/foam inj ection - pgm61;';';~~~5~:J~- NP feogdci~j,12~- ~.~~~- 1)·'?:'oO[~\:}:;::"?!?l::J.'0·'.~.;.,~...~;.·H _ - ....., - ...3.25 58 GP Less sand,subrounded fine gravel, No recovery of cuttings - - 1---+-+-+--t--f--f--+--:=-::::----=..,....,.,.,......----.......-------4T.D.-328Ft. ~,30 ,.1.35 - ..J.40 345~- - - - - - - - - - Boring NoflD8G.;r 'Sheet __7_of _7__ - lfflJiIl ~JEI :(~(0 SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _~_ Date 3/25/83 Boring No HD83-2 (F) Feature Relic t Channel Coordinates:N 3229506.2 E 746104.4 logged by tJMB,BAW/I.EM Angle (from Horizontall 9_0_o Ground Elevation __--=2:..2,c..::1~4~7~._1 _ Bearing Rock Elevation ~2"-,0,,-6,,,-9~.C"-6--=--- Date Started 2/7/83 Total Depth 87 .0 Date Completed 2/7/83 Ground·Water Elevation_-_-_-_ C 3 c:i ru C ."0 .c .2 0-ru-Zo.~=.c!t) _I:-'"ru>-oll):COlan;0.>-ClICD~E~-l-oci 01>0.0 Soil Description<1»Cl O ",-o.'t:l ~~I:0 ~..J..-Q~._0 (/).:EI:rut) ~a:"''''011I .,.Jru C.l (/)jiio.a: c .E-.; CE Remarks 2 OJ.: ORGANIC MATERIAL 90 -HAM,CI fQ·¢p;~JK~y(t1 M/c 13% M/c 17% H~:;::;,:;;??:~;/i:;:J~0J NP M/c 11% M/c 12% Ut:(:::::}):'.:.:~ LL 34 PL23 PIll CL M/c 19%I~::\~:~~;:?fi:;~}:{:ra rtf:::::;:~~~~:\:Y.:·:}/J21 LL2 OPL 17 PI3 ::r;.V:O.Q .'it~ML.~\J":',!·o.o~[9:':l~Gf:~q.::'yjMI C=% M/c 18% !:i>;{:;.::/:nr:·:·Y.!a M/c 6% M/c 6% Pipe cocked at 10.5 Ft.,moved hole,redrill ~~~~'/?-!miij:,:,@ M/c 13% .Water @ H;·o.':F-t ,me ~um ense wet, grayish brown,subrounded,fine to coarse,occasional cobbles, less sand and silt. Olive gray. Less clay,light olive gray. Olive brown. COBBLE. Dark grayish brown. Very weathered, Slightly less silt,light olive brown Some dark gray clay clumps,olive brown,damp. Few dark gray silt clumps. Boring No!ID83-2 Sheet __1_of _2__ Silty SAND,less than 5%gravel, moist,olive brown,fine to coarse weathered rock grains,sub- angular gravel. SM Medium dense,grayish brown . Silty,gravelly SAND,wet. SM 91,j.ve]:U;9WP,fiIle to~.GoaJ:'se .. subangularto subrounded gravel. SM SM SW 8M SM 8M SC SW "SH 50 100 1~ 2 14 10 1 16 11 12 10 13 14 15 53 76 48 43 45 72 98 30 50 202 40 45 3 GP 4 GMF- 5 100 I GM6 7 87 .... ---' SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_of 2__ Date 3/25/83 Boring No HD83-2 (F) Feature Relic t Channel Coordinates:N 3229506.2 E 746104.4 Logged by WMB,RAW II.EM 90°Angle (from Horizontal)__---=--=--_ Bearing Date Started __--=2.!..,1..:...7.!..,/,.::8,.::3 _ Date Completed _--=2~/-..:.7--'-/___.::8:..:3=---_ Ground Elevation __.::.2..!...,.::.1_4.:..-7-=--._1 _ Rock Elevation __---"2:..l0.L!.6L;9~.~6~--- Total Depth 87.a Ground-Water Elevation _ Remarks ~::>~:~·:~:':~i0?f.~:~~ Mlc NP 6% 1if~{i;~!!B~~';~:f?:::;:~ NP Soil Description Occasional gray clay/silt lamina.tions Olive brown. Olive gray. 8W MOre large gravel ,occasional cobble . 8M Yellowish brown. 8M 8W 8M 20 18 17 19 100 C 3:0(1)C."C .c:.S!(1)-Zo.::::1=.cl!!u0-_0:1 oil)at;_C 0.>QI>--QI :EelCQ::::I E:ii -I-(,).el>0.0QI>.!a'8 0."C 0 CoCQIOl-E C 3:...(l>u l!-l W a:(/).5 ~0:1 o QI -lQl ~ 51)ino.a: 65 Wfi;::w~mj~@i(f??El NP MIC 3% PNEUMATIC PIEZOMETER @ 75.5 Ft. HAM,DDH P TOP OF More coarse gravel,olive gray. No recovery Becoming coarser and drier. Less gravel,olive yellow.8M 8W 8M 21 23 22 80 85 T.D.=87.Ft • 90 """I I 95 100 Boring No.HD83-2sheet __2_of 2 J :~,~ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_1_of_2 _ Date 3/25/83 Boring No RD83-3 (L)Angle (from Horizontal)9_0_o__~ Feature Relic t Channel Bearing ---.----.-=--_ Coordinates:N 3231246.7 Date Started 2..,;.:.../'=-7:.,/8-=-=-3 _ E 745855.1 Date Completed 2'--/8-'-/8_3 _ Logged by REM.WMB.RAW,EJK,DAF ILEM Ground Elevation 2-=-,2_2_0_.0_·_ Rock Elevation _ Total Depth 82.5 r Ground-Water Elevation _ r- I - C ..c::.2o..i; ...>c ...m. ::0-_c I:llj .218ce CIl-_<a a.>e; <a-lJ)": Soil Description c: .2-; 'E... E 2-;..: Remarks 90 -RAM,Cr 5 Silty SAND,20-25%gravel.Moist, olive brown. 1 2 SM Silty SAND,10-15%gravel.r:t2ttl/i02! Very dark gray,fine to coarse.LL21 PL14 PI6 Rounded to subrounded gravel.M/C CL -ML Occasional cobble,frozen.15% 15 3SS 28 20 LL15 PL14 PIl....35 ML 50 M/C 12% 4 Slightly more clayey silt,sub-@\/:)i:f2%}'0JMLroundedtosubangular gravel.LL19 PLl5 PI4 25 ML-CL M/C 15% 5SS 50 5"5"Ice lenses. 30-6 SM Slightly less clayey silt,dark gray,If;-:';}:~::~~(~ rounded to subrounded gravel,LL20 PL14 PI6 polished and striated.CL-ML M/C 11% ~5 7 M/C 14% 29 E1t.;).::~:::::·i~8S ~§24 SM4084 LL18 PLU PIS Boulders/cobbles to 58.5 Ft.ML-CL r-M/C 11% r 9 M/c 6% HA.."1,DDH ai49"':75\ Ft.\ Boring No.HD8 3-Sheet __1__of __2_~ 3 !~i@ SUSITNA JOINT VENTURE SOIL BORING LOG @ATANA DEVELOPMENT Sheet Z of Z Date ~z5T83 - Ground Elevation _--k2-->-.~2~2J.l.O~.J.l.O _ Rock Elevation __----:==_~_-­ 82.5'Total Depth Ground-Water Elevation-==-==---_ Boring No HD 83-3 (L)Angle (from Horizontal)~9uOLo _ Feature Relic t Channel Bearing Coordinates:N 3231246.7·Date Slarted __-"ZcLl..!.7.L1-",8~3,----_ E 7458 55.1 Date Com p leted ........ZJ./..!"8u/..!,,81.,,,,3'----_ Logged by REH WMB RAW EJK DAF ILEM,,•, I: C-oil)c·.2;:-"C <G.c .2 Il)-Zo.:1=.c~.!:!.21:_01 0..,c0.";c.>Il)>--Il).cOl!Xl:::!E ai -I-o·Ol>0.0 Soil Description Il)Remarks<1»Ol o o."C (;)Co E01-;:..~..1oJ!!._0 (/)E E I:Il)u 2olI!..Ill!Clwa:01 01 iXio.a:Ui50(/) I: ~- ~5 - HAM,CI @ 58.5 ן-Ft.-ass 52 Mlc 12% ~O 50I~- >-- 1245 11 Moist.Mlc 4%Us - I--1202 1Z Mlc 6% ~O COBBLES/BOULDERS.- -~52 13 GM Silty,sandy GRAVEL,WITH COBBLES.r:CPJ?e@ US Moist,dark gray,NP -subrounded to sub angular ,Mlc 5%fine to coarse.r\Refusal at 77."->- Ft./ JO HAM,DDH at 77. Ft.- T.D.=8Z.5' ~5 - >-- ~O - I-- J5 - I-- 100 Boring No.HD83-Shee1 3 Z ot _---'Z=__ n- SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of 2___ Date 3726/83 Boring No HD 83-4 (0) Feature Relict Channel Coordinates:N 3233160.2 E 747719.7 Logged by IEP,RAW T.FM Angle (from Horizontal)__9_0 _ Bearing =-=-_ Date Started 2[9/83 Date Completed -=2-'-/.::.9-'-/.=.8.=.3 _ Ground Elevation _2..-7-,.2-4-6-.-7------ Rock Elevation __N_!_A _ Tota!Depth 94.0 Ground-Water Elevati61'1-__-_ r c ~0<1)'E.'tl J:.2 0-<1)-Zo.~=J:l!!u_C -'"<1)>-Olt):E ClQ.ca III ~0.>-<I) Elii -l-Oci 01>0.0 Q)'"01 0 o.-c CoQ~",-~...~-I._0 (I)':Ec Q)U !!:!.D:"''''0<1)-IQ)e" (I)iijo.D: Soil Description Remarks Peat OJ 90 HAM,CI 5 Easy Drilling to 20.0 Ft. S Slil 288M 11 12" 11 15 Silty SAND,10-15%gravel.Frozen, grayish brown fine to coarse. Sub rounded to subangular gravel brown- ish gray.;Contains 6"of peat in upper portion df-spOOn.Occasional cobble. NP • M/C 15% aIR N.P. ~Hard Drilling at "'"21.0 Ft.o . o \0 o ~ <Il..co 1-1 Po< rl <0 j LL ~t/{f11 3 ~ML M/C 17% Water @ 35.0ft. Boring No.HD83-=:-Sheet 1_of 2 4 More gravel,moist Loose Sand. Boulder @ 27ft. Gravelly SAND,5-12%silt dark gray fine to coarse,saturated,angular to subangular gravel,occasional cobble. striations More sand. Sandy 81 gray,varied 8W SM ML 8M I 8M SM-f-:"!'.......---.-----.......-~r---.................,..."......,f,....l.,....·n-e-! wet,dark 7 20 35 r .5 ~ 30-6 1+0 !'"'" 45 I'""" i """50 - , Sheet __2_of _2_ Date 3/26/83 Ground Elevation 2.246.7 Rock Elevation __==-=---_ Total Depth _~9~4_._uO'___ Ground-Water Elevation-===-_ Angle (from Horizontal)_---'9'--'0"----_ Bearing __-==-_ Date Started _.L.2-1-1..::J.9-1-/.u8w3'----_ Date Completed i:.2.f-1.:;z9.f-/.u8..:l.3 _ WATANA DEVELOPMENT SOIL BORING LOGIltimJE SUSJTNA JOINT VENTURE Boring No HD 83-4 (0) Feature Relict Channel Coordinates:N 3233160 2 E 747719.7 Logged by JEP RAW /LEM, c C ~Co>c.~:8=.2 0-0>-zo.:1==2!u '"-'"0ll'l C--_C o.c:;0>>--ell :EC)0.",CQ:l E 0>-I-C).C»0.0 Soil Description ell Remarks..>.~8 o.og 0 Co Ec.2!tII-~..O>u E...I(I)':E c 5we::til",o ell ...10)c:I 50 (I)iiio.e::'"<: >-No water @ 5J ft -More gravel/cobbles Hard Drilling at 55 53-55 Ft.""-.....- - l!8 9 SM -btB:·,,·:····::,[l0%2~.''.::'::':::::'::: 60 LL17 PLl6 PH ML_ 1-=1C3.....:.,'::.:.,:,:w/21 10 SM Silty Sand,15-20%fine '.z·:·:·:·:·:::::;:::to coarse grave '-dark gray,.fine to coarse,subangular.LL17 PL14 PI3 - to subrounded gravel ML-CL 65 ~.- >-- ...10 - >--~9 11 Varied clumps M/C 15% J5 - Clay,10-15%fine to coarse sand.Variec -12 CL silt/clay clumps dark gray a1t@1////I/A - LL 28 PL 19 PI 9 -lI 0 CL - M/C 15% >-- Jl5 -pYli.:~i!}W/#/113SCClayey,gravelly sand,damp brownish >-~80 14 SM gray,fine to coarse subangular to l~o8i::::;::::i;:.,:w -subrounded gravel .~"":....:...:. 90 Less clay,grayish brown.LL 19 PL 14 PI 5 I--ML-CL - Hard Drilling at >-91.5 Ft.- REFUSAL ~5 T.D.=94.0 ft.- >-- 100 Boring No.HD8 3=-Sheet __2__of 2 4 SOIL BORING LOG WATANA DEVELOPMENT Sheet _1__of _3_ Date 3/26/83 -Boring No HD 83-5 (Q) =eature ReI ic t Channel :oordinates:N _3_2-=-3_4...:.3...:.5....:;0....:;._6 _ E 748873.3 Log.ged by ETK,DAF,RliliT,JEP/LEM- Angle (from Horizontal)_9_0 _ Bearing __-==:.;=----,-=-""'"_ Date Started 2/l 0/83 Date Completed .=2:.:../_1....:0:.:../_8....:3 _ Ground Elevation 2,283.7-~------- Rock Elevation _.::,,=,"""--=..--_ Total Depth 138.0 ' Ground·Water ElevatiolT"_-_-_ c ~dill 'E."0 .c:.~o-lD-Za.:::I':.c:l!u-'"a";_c o.=-<II'"'Oil)-<II :COla:l:::l E:D -l-°ci Ol=-0.0 Soil DescriptionII>=-.218 0."0 Coc~",-3:,-l!....II"""(/).5:E~II>U f:!:!-a:"''''all>....1<11 Cl (/)aia.a: Remarks 90 -HAM,CI 5 CL Dark gray ML 8~i~~~H~ LL22 PL16 PIS CL-ML M/C 47% ~ LL31 PL20 PIll CL M/C 75% LL46 PL28 PIl8 CL/HL M/C 41% M/C 45% ravel/Cobble layer Sandy clayey SILT,less than 5%gravel, dark gray,frozen laminations,ice lenses. Silty SAND,less than:5%gravel,frozen olive brown,fine. ~y ., less than 5%gravel. gray,clay layers Occasional cobble. CL ML CL SM 3 2 1 4 SS H 5 13 35 30 25 ,- I f ra- I ~ I 35 Boring No.HD83-Sheet 1 5 3of _ G =2.75s LL53 PL31 PI22 MH M/C 30% LL!fWff~oCL ~q's~B~an y olive gray,rounded to subrounded, to coarse,occasional cobble Wet. Slightly laminated CL GW MH6 9 8 7 SUS/TNA JO/NT VENTURE Boring No HD 83-5 (Q) Feature Relict Channel Coordinates:N 3234350.6 E 748873.3 Logged by ElK,DAF,RA1J,lEP/LEM C 3:ci III 'E."tI .c.2 0-Ill-Zo.:::s=.c~u_C -Ill CD>'0",:eelQ..c;m:::s 0.>-CD E ~-I-().el>0.0Ill>Cl O o."t1 0 Co..-3:...~....o~-()CIl":E C CDu w a:OCD ....(1)Cl....Dio.50-CIl a: SP SOIL BORING LOG SUMMARY LOG WATANA DEVELOPMENT Angle (from Horizontal)_--::9c..:0=------_ Bearing ---,-------,,...--_ Date Started 2/1 °/83 Date Com pleted -----=2:..L/--"1'-"0'-'-/--.::8::..::3'----_ Soil Description Me ium to coarse Sheet 2 of 3 Date 3T26/83-- Ground Elevation 2 ,283.7 Rock Elevation _-,,--0--_ Total Depth ----=1c:::3:...:8~.:...:0~_ Ground-Water Elevation_-_-_-_ Remarks , 55 65 70 5 11 80 Wat~r @ 54.oft to 86.0 ft Flowing fine to medium san<i More grav~l and cobbles,coarse sand. AND -,-, fine to coarse,subangular to sub round ed gravel,occasional cobble P MIC 8% Easy Drilling, 61-66 Ft.lots of water Pneumatic Piezometer @ 70 Ft. At 74 Ft.water flow reduced 50%Fractured Out of water @ 8 ~~J:;:~i;!:@2} LL18 PL 16 PI2 ML M/C 9% - 95 100 74 14 SM More silt,dark olive gray Water 94-95.0ft to 108.5ft Cobble/boulder 96.5 to 98.5 ft Hard Drilling, 86.5-98.5 Ft. ~ I Boring No.HD83-Sheet 2 5 3of _ WATANA DEVELOPMENT Angle (trom Horizontal)__9_0_o Ground Elevation __2-'-,_2_8_3_._7 _ Bearing __----'=7-_-.,-Rock Elevation _ Date Started 2/10/83 Total Depth _---'1:...:3:...:8:...;.'-'0"-------- Date Completed 2/10/83 Ground-Water Elevation-..e-'----_-_ .... Boring No HD 83-5eQ) Featu re Rei ic t Channel Coordinates:N 3234350.6 E 748873.3 Logged by E H<,DAF,RaW,IEP/LEM SOIL BORING LOG SUMMARY LOG - _••-< Sheet_3__ot_3_ Date 3/26 /83 c ~-ci G>c·-c .c.2 G>-Zo.::I::.cl!!_c -'"G>>-01/)'5.;0.'"-G>113::1 e~-I-°ci Cl", 4)'"ClO o.-c Coi""'"c.~"'-3 ~._0 cn..!:E C G>U W e::"''''o G>....l G> 1 oIT'cn iDa.e:: 15- 105 Soil Description GM Silty sandy GRAVEL,saturated,olive gray.subangular to'subr9unded,fine to coarse,with cobbles.Oxidized coating of gravelcobble/boulder;l 04,0 to 109.0 t Remarks o 115 120 4 16 GW End Water 108.5 it GRAVEL WITH COBBLES,20-25%medium to cuarsesand;les's'than 5%sflt,moi.st olive gray,rounded to subrounded,fine to coarse. Less cobbles (7) Hard Drilling 104-109 Ft. Hard Drilling, 111.5 Ft.more water return Drilling easier @ 115.0 17 18 SM Silty SAND less than 5%gravel,wet, olive gray,fine. Less moisture @ 126ft -GRAVEL WITH COBBLES,20-25%silt and sa d wet,olive green.Oxidized gravel @ 132ft. 150%Fract I Hard D:dlling, 131.5 135 19 20 r- U+O !""'" 145 ..... 150 Yellowish brown sand and rock fragments T.D.=138.0 Ft. Easy Drilling, i33-134 Ft. HD83-Boring No.Sheet 3 of 3 5 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_1__of_3_ Date 3/26/83 Boring No liD 83-6 (J) Feature Relict Channel Coordinates:N 3230265.7 E 744788.6 Logged by DAF,RMl,JEP,MPB/T,EM Angle (from Horizontal)_-=-9..:::0_o Ground Elevation 2,211 .2 Bearing Rock Elevation ~~~_ Date Started ~2"-1-/....1....1.L-/~8...3,---:--,-----Total Depth __1'-"2<--6""--"-.....5 _ Date Completed _=2-'--1-=1-=2:...<./--=8:...:3'-Ground-Water Elevation~~_ r \ c =:ci G>'E .~~1.2.c .2 0-G>-ZOo ~.::-'"oil)c.c;_c 0.>G>>-..Q).J:0)ll:l~eiD -~°ci 1»>0.0G>>.~8 0."C g g ~....Ic~",-=:- !!!-a:(/).:Ec o G>...I G>Cl"''''(/)iCo.a: Soil Description c: .S!;; C G> E 2 Ui.: Remarks 5~0-HAM,CI ..... < 5 Frozen to 11.0 ft.no samples taken Drive pipe blocked -10 SM Silty SAND 15-20%gravel,damp,dark ~F'i":':":i:i':'WL2:.::.:.,;::;.:: 26 1 grayish brown,fine to coarse,sub round M/C 11% 15 ed gravel,striated and polished G =2.69s .j.J.-"'"cocked,Pipe move 0 ho ~jfdtj!~:~vJliii N 20 2 SM More gravel,less sand and silt,sub-- -...... angular to subrounded gravel,damp,oli e 0 .j.J gray <U ,..Q 0 H 45 3 P",'~~-:{}:::~,::~;,:.v$1SMClayey;silty SAND,15-20%gravel,damp ,...;............. 56 olive gray,fine to coarse,rounded to Cll LL17 PL14 PI3s r-subrounded gravel,striated and polished H ML<USiltclumpscontaincoorsesandand~ E-<fine gravel30 .- Boring No._H_D_8---z~:--Sheet __1 _of __3_ LL32 CL t~ PL23 PI9 LL44 PL27 PIl7 CL/ML E1:;:;:\/0m'/Z! LL29 PL20 PI9 CL G =2.74s Less sand,olive gray Dark gray clay/light gray silt,less tha 10%fine sand CL CL I~ r SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet ----.2-of ~ Date 3/26/83 Boring No HD 83-6 (J) Feature ReI ic t Channel Coordinates:N 3230265.7 E 744788.6 Logged by DAF,RAW,,rEP,MPB II.EM Angle (from Horizontall __9_0_o _ Bearing Date Started 2/11 /83 Date Completed _2=--/=-1=-2.!-/.;:..8=-3 _ Ground Elevation 2,211 .2 Rock Elevation --::-:c--:-~=------ Total Depth __1_2_6_._5 _ Ground-Water Elevation~-=..:-=..:-=__ """\ Remarks Hard Drilling t~~h:){?~:J%Z] c .S! OJ C CD E.s "'.E Soil Description ore sand .and gra.vel,brownish gray ravelly,sandy-SIL~,dry.olive gray .ine to coarse,subrounded to subangula ravel GP Sandy GRAVEL,5-12%s.ilt,damp"grayish M rown,subrounded fine to coarse ore sand"saturated WATER@ 60.0ft to 86.0 ft SM "0 .cl!! -41 Cl>Co CD U ...l41a:: 8 7 c·j:: 0Ll)U o::.. 041iii0. 9 o CD Zo.. 41>--I- 0."0Ec <G<IIen CD-_<II 0.>E~ <11-en.E ~0-_c alj Cl O._u a:: C .c:.90..-; CD > CCD §. 50 65 o o 10 SW Olive brown SM 75 More gravel subangular to subrounded, slight oxidation lfY::))~ LL PL:Ll PI CL-ML 11 85 12 GP Sandy GRAVEL'less than 5%silt olive, gray,saturated subrounded to subangula 13 Silty sand,less than 10%gravel light a olive brown,fine to medium oxidation coating. 14 SM Laminated silt clumps 95 15 SC More clayey silt 8M 80 100 Boring No.HD83-Sheet -----'2"'-----_of 3 6 I ~1 -----' IDJJjIl~~~!IfJA~(C1{DJ SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT 3 3 Sheet __of __ Date 3/26/83 ....Boring No HD 83-6 (J) Feature Relict Channel Coordinates:N .....3c<;:2~3wOc<;:2"""6'-:!5!..o-L7:--_ E 744788.6 Logged by DAF,RAW,lEE,MER!T EM Angle (from Horizontal)__9_0 _ Bearing -__~_'__ Date Started ~2-1-1..l.]..l.1+I.o8..;l3'-.,-------- Date comPleted'-.::2:..!';-=1:":2"-!/~8__=3~_ Ground Elevation 2 ,211 .2 Rock Elevation _ Total Depth _----=-1='-3~6L_/-"'-5_'~ Ground-Water EJevation_-_-_-_ 8M SC Silty,clayey ~8AI\lJ),.less than 5%gravel 8M olive yellow,fine to medium,silty/ clay/sand layers. Remarks k:~~:·::}>4>?@ LL28 PL22 PI6 CL-ML c .S! OJ 'E Ql E 2 '0 -= Soil Description Slightly more GRAVELLY,dark yellowish brown ',More gravel 16 71 7 S 29 18 c ~°al 'E ."C ..c .S!0-GI-Zc.~;:..c!!0_c -'"QI>'0\1'):Coc..(;c.>-GI1I1~E~-....(.)0 0>C.OGI>.218 c."C Coo~",-~...Qlu ~-l a::tn":Ec o GI ....IQI c:J!:!:!.'"'"tn iDC.a::-I i 115 120 19 Gravel altered/weathered to white/ yellowish brown Hard Drilli - 1~5,- " 130 r- 20 SM Less clay,gravel,yellow,bucy. REFUSAL @ 126.5 Ft. T•D.=12 6.5 Ft. ft!~@}}>/i:~ LL22 PL20 PI2 5 .... 140 .....8-5 r 150 Boring No.HD83-Sheet 6 3 of_-=3_ ffi 11l.~fE'l~i~{ID SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _2_ Date 3/26/83 HD 83-7 (D Acres)Boring No _ Feature BeJ jet Channel Coordinates:N 3232100.1 E 743745.9 Logged by -JEP ,DAF,RAW/T.EM 90 Remarks 2095.5 C .S!a; 'E II> E I:;;; .E Ground Elevation _ Rock Elevation ----0====----- Total Depth 82.0 ' Ground·Water Elevation _ Soil Description Angle (from Horizontal) Bearing -.:==-_ Date Started ....2~/'-.!1~2'_.L/~8~3~_ Date Completed 2=.L/~1<-.2L/~8~3 _ o :E CI0.0 f!~ CJ "C ~e-<I>C1>Co lIlo~lIla: lIl--~a.> E t ~-(/).Er ..... -10 1 SP Poorly graded SAND,15-20%fine gravel lessthanS%silt dark olive ..fine to coarse,subrounded gravel. "Loose"9.0 to 13.0 ft. Easy Drilling, 9-13 Ft. MiC 31% N 00 o +J t'?;f:~~~:V/I///A ~ ~ 0:: P.; ft Laminated Silt/clay,moist4 2 ML Clayey SILT,10-15%fine I'""'olive gray.. More fine to medium sand,gravel - 3 ML Less sand,more silt Laminated silt/ clay clumps more clay,TIlOist olive r-gray - 30 r- ~3S 40 .HD83-1 2BormgNo.Sheet of _ 7 ,... I 45 50 S ML Laminated silt/clay,20-25%fine sand ICL Olive. I ~W////hl M/e 23% SUS/TNA JO/NT VENTURE Boring No HD 83-7 CD Acres) Feature Relict Channel Coord i nates:N -.;3"'2.....;3"'2~1....OAOJ..-.lb------ E 743745 9 Logged by IEP,DAF,RAW!LEM SOIL BORING LOG WATANA DEVELOPMENT Angle (from Horizontal)_---'9_0'-o _ Bearing Date Started 2/12/83 Date Comp leted<.2+I.....I....2-4IJ.S.L3.L--_ ----' Sheet ~of ---.L- Date 3/26/83 Ground Elevation 2095.5 Rock Elevation ==-_ Total Depth _"'-8....2~..l.IO'___'_ Ground-Water Elevation~=",-----_ c ~ci Cl)"E.-c .c .2 0-Cl)-Za.:::I::.cl!!0_..--_I:a.>11)>-oll)-Cl):CCla...l:ll:::l E Qj -I-U o CI>a.oCl)>Cl O a.-c I:0011)..-~...~....I._U (1).5 E I:11)0 jjj a::011)....III)0....iii a.515 (I)a:: Soil Description c: .2 OJ"E <U E 2 iii .5 Remarks 5 60 65 70 75 a 6 7 8 9 SM GM SP More varved SIlty SAND,no gravel,damp pale olive fine. Sandy clayey,silty GRAVEL "Dry", olive gray,fine to·coarse subrounded with cobbles Less clayey silt.more fine to coarse sand,Dark olive,gray rounded to subrounded gravel NP H/c 3% r;6?J/ij!~!~:Wj LL18 PLl4 PI4 ML-CL M/C 2% ::0::: ~ ::>:=: ,...:l H <l:l Pipe cocked, abandoned. 85 90 95 100 T.D.=82.0' Boring No.HD83-Sheet ---=2'----_of 7 2 SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1_of _2__ Date 3/26/83 .~ Boring No liD 83-8 (E) Feature Be'jet Channel Coordinates:N 3228853.6 E 745428.5 Logged by JEP,MPB/I,EM Angle (trom Horizontal)--'9:"-'0=---Ground Elevation 2,217.2 Bearing Rock Elevation _ Date Started 2 11 3/83 Total Depth _-'-Z..I.!8,-OC•..uO'---'_ Date Completed '-2-/-./...l.1....J3'-1--/..u8....J3'--Ground-Water Elevation _ '"'"'I r C .c .2a.:; Gl '"CGl @ ~0-_I: lD~ .218 I:C u:EC) 0.0f!!...J (3 Soil Description c .S! 0; C ~Remarks .5 '".E 5~0 -HAM,CI 2 ~;:;~\j\'~~:~:::::.J~. N.P. Hard Drilling @ 36.5-37.0 Ft. 42.0-42.5 Ft. 45.0-47 .0 Ft. LL15 PL14 PIl .w "'"o oco o.w Boring No.HDa 3-Sheet 1 of8------ Silty SANU 10-25%gravel damp,dark grayish brown,I fine to coarse,Angular to subangular gravel occasional cobbles. Humid Gravel/cobble SM SMMore gravel Gravel/cobble 8M More silt,Olive gray 8M Less gravel,grayish brown.Subrounded to subangular gravel 1 3 4 6 5 2 9 8 ..... ..... !~(I) SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_2 __·01_2_ Date3 /26/83 Boring No HD 83-8 (E) Feature Relict Channel Coordinates:N 3228853.6 E 745428 5 Logged by TEE,MPB /T.EM Angle (from Horizontal)_~9,,-,0,,-----_ Bearing Date Started --:.2.f/.....l~3'-1/'-I.8....3.>-----_ Date Completed _2"'jf-,ll!"'3.;J-,f-'/8~3 _ Ground Elevation ~2,-",~2~1c!..7--!•.£,,2 _ Rock Elevation __~_ Total Depth _-I-7.o8--u0 _ Ground·Water Elevation_-_-_-_ :.£ Remarks LL20 PL18 PI2 ML Hard Drilling @ 66-72 Ft. c: .E BI:CIl E .5 1II.: Soil Description T.D.=78.0 Ft. Boulder/cobbles 66.0 to 72.0 ft. Weathered/altered rock fragments 78.0 ft. Silty SAND,less than 10%gravel "Dry" SM olive,fine to medium subangular ~ subrounded gravel.Few weath.silt clumps (oxidized) SM Silty,gravelly SAND,moist very dark grayish brown,fine to coarse. Subrounded to subangular gravel WATER:@·59.0 ft.to 61.0 ft SP Poorly graded SAND,.20-25%graveL ::E: SM 5.:..12%·silt,moist,dark gray.Fine ~ to coarse~rounded to subrounded gravel 5 ,..J ~ SMsilty SAND •.less ..t.han 10%fine gravel, wet,dark olive gray,fine to coarse subangular to subrounded gravel c ~c:i CIl 'E .'tl .l:.E 0-CIl-Zo.::I::.l:!!!(J-<\I--_I:0.>CIl>-0",-CIl :em0.<11 a:I::I E Gi _t-°ci m>0.0CIl>m O 0.'0 I:0CCIl<11-~...!!!...J._0 en':EI:CIl (J!B.a:<II <\I OCll ...JCIl c:leniQo.a: 85 100 Boring No.HD83-Sheet 2 8 2of _ SUSITNA JOINT VENTURE SOIl...SORNG LOG WATANAP~VELOPMENT Sheet _1_~of _3_ Date 3/26/83 Boring No HD83-9 eM) Feature Relict Channel Coordinates:N 3231621.8 E 746381.5 logged by lEP,REB/LEM 90°Angle (from Horizontal)~:.-_ Bearing ==-~ Date Started 2/13/83 Date Completed 2/13 /83 Gro und Elevati on 2=--z...:.2::..:3=--7'--.:-.6-'--_ Rock Elevation -----=-===----c--:---- Total Depth 110 .0 ' Ground-Water Elevation-'-==--_ 3:0-_c m:::l Qlo.-(,)a: 11>-_<IIa.> E :D <II-(/)-= t.l :CQl 0.0f!....I c:l Soil Description c .2 0; E CI> E 2u; -= Remarks 5~0 -HAM.CI Hard Drilling @ 39 Ft. R.i:r:~~n·:?i"·w01 NP ~.lY~U!~'0Z1 LL16 PL14 PI2 ML o +J Boring No.HD83-Sheet __1_Of __3_ 9 Silty~gravelly SAND, grayish 'brown,fine to coarse subangular to subrounded graveL o ,...; ,...; o. 20-25%gravel,dark olive gray. Silty SAND,15-20%gravel. "Dry",olive,fing to coarse, rounded to subrounded gravel, few silt clumps. Humid,olive gray • 8M 8M SM 8M 8M 2 3 1 4 5 6 9 r I Il, r r .~ f 7 ,..... 8 r ImJJllllj ~IEi:~.@) SUS/TNA JO/NT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _2_of _3_ Date 3/26/83 Boring No HD83-9 (M) Feature Relic t Channel Coordinates:N 3231621.8 E 746381.5 Logged by .IEP,BEH II.EM Angle (from Horizontal),__.....:9:....:0::....o Ground Elevation 2.237 .6 Bearing ---..:.:=:...-_Rock Elevation Date Started ----;4~~l;.§3------------::-,..--,---=----T~al De~h 110.0' Date Completed _-----"2:..!./.....:1:..::3c:....!/~8::..:3~Ground-Water Elevation ---------- C 3 c:i Ql 'E.'t:i .c .2 0-Ql-Zc.::J::_<II .cl!!() am _c c.'"Ql>-OLl):COlID::J E~_l-uci -Ql Ql '"Ol O c."C Ol",c.o OQl <11-3 '-Co Soil Description g ._u (/)..5 Ec Ql(J l:!...1 a::<II <'ll OQl ...IQl c:l 50 (/)iijc.a: 100 SM SM SM SM SM More gravel,_ Silty ,~ravellySAND,"Dry"dark gray,flue to coarse,·subangular gravel,occa,sional cohble. Less silt Slightly more silt,dark gray. Subangular t'o subrounded gravel. More gravel. Less gravel,more silt. oli e c .51 ~c Ql E ::J:- '"..: Remarks ~ LL16 PL14 PI2 ML b"'S'(::}!':}~~;)~ NP ~>.;'!:~:}i0Zl LL18 PLl5 PI3 ML Boring No.HD83-Sheet __2_of ---.J __ q Ii r I ~'i~;'~1!P! SUS1TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_3_of_3 _ Date 3/26/83 Ground Elevation _2=--<-,;::.2.=.3...:..7...:..._6 _ Rock Elevation _ Total Depth 110.0 I Ground-Water Elevation...:..-::.:-::.:-=---~ 90 °Angle (from HorizontaJ)~:::-_ Bearing Date Started --'2""/<.-1::.;3:::.../<.-8:0::3"----_ Date Completed __=-2L/..=.1.:=.3L/~8.:=.3 _ Boring No HD83-9 (M) Feature Relict Channel Coordinates:N 3231621.8 E 746381.5 Logged by TR"P RF.H iT EM.,, c C 0(1)c·-0 .~ .c::.~~-ao-zo.::1=.c::!!u -; -«I 0..,Ca.ft;_c 0.>ao>--ao :COla:I::I E:D _I-uci 01>0.0 Soil Description ao Remarksao>.218 0.-0 Co Eo~«1-3:...~....Itil':Ec ao u 2cr:0(1)....lao c:lw«I «I iijo.cr:(jj 160 til .E ~50 20 Slightly more gravel. t-- ..1.05 ~J;tfji?:}~~- 21 SC Less gravel,more clay.LL23 PL15 PI8 f-CL - 1 1 (1 U~;,.l.:t~.,;.(?\- T.D.=no ..o,Ft. I-- ,..l15 - I-- I--I·- I-- f--- I-- I--- I-- I--- I-- f--- I-- I--- I-- r- I r- ! Boring No.HD83-Sheet 3 9 3of _ !lJ lEi ~irt:{D) SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 1 of_1 __ Date 3/31/83 Boring No HDS3-49 (K)Angle (from Horizontal)90 0 Ground Elevation 2,207-,-.~2 _ Feature Relict Channel Bearing Rock Elevation -=N~/-=A~,,__----. :oordinates:N -",-3~2",3:,::0~7..:::0,-,"S,-,•..,3~__--,--_Date Started 3'-'-/....,,2'-"0'-'-/-::S:..::3'----Total Depth 38.0 E 745271.5 Date Completed 3/20/83 Ground-Water Elevation -- Logged by -JE~ c ~0 c ."0 ..c:::.S!0-lll-z~:::1=..c:::l!!.!:!_I:_Il! lll>O oll)--al :::I c.>-<I)..c:::Clo.ll!Et -I-°ci Cl>0.0III>.~8 0."0 ~I:0 f!....Ic~'G-Ee:t III "a:(J)":.2 ....Illl C1!!!.Il!Il!0.(J)al a: Soil Description Remarks 5~0 -HAM;CI ..... I 5 1 54 IS" 17 " GM GM GP GM CL ML CL Silty,Sandy GRAVEL,Medium dense. humid,olive gray:.light gray silt ahdtlay clumps,fine to coarse,with trace organic matter. Frozen:(CL-ML) Dark grayish brown,subrounded to ~Ubang!llar. More gravel,5-12%silt.dark olive gray. CLAY.20%fine sand.hard ,humid, dark olive gray. Proportions of clay and silt vary slightly. Occasional lens of fine sandy silt. wet. SILT -moist to wet. Less than 15%sand. T•D.38.0 Ft. ~~S~~K~t12 Organic 4% LL23 PLl9 PI4 (CL-ML) 1~';:Q;3j~(;\d~1 ~~. LL34 PL20 PI14 ~~LL22 PL19 PI3 ~M/C 31 (WWffMmi LL32 PL22 PIlO Boring No.HD83-Sheet 1 49 1of __ r SUSITNA JOINT'VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _1__of _3_ Date 3/31/83 Boring No HD 83-50 (P) Feature Relict Channel Coordinates:N 3233761.2 E _748255.0 Logged by JEP.REH.WM:B •.JFB LLEK Angle (from Horizontal)__:<...90=---Ground Elevation 2 .290.8 _ Bearing Rock Elevation _ Date Started 3/20/83 Total Depth 119~~ Date Completed ----.lL21 L,---,8",-,3~~Ground-Water Elevation _ c C-o QI c·'t:l ,2 3 ~..c .2 0-QI-ZQ.:::I::..c:!!<.l-'"olJ'l C--_c Q.i=QI>--Q):CO)Q.<lI m:::l E(I)-I-u·~gl~~Soil Description QI RemarksQl>.218 Q.'t:l 0 E,.,..o~",-3 "-en':E c =!:!.IX "''''o Ql ...I (I)<:l en inQ.IX in.: M/C 16% Hard Drilling @ 33.5 Ft. fti.,C?:§t\//:J'Z1 NP G =2.70s LL24 PL16 PI8 LL20 PL16 PI4 Gs =2.70 Very hard Dri1Il g ail:~'/~<%j LL20 PLl5 PIS 5~0 -HAM,CI Very dark graySlightlymoreclay. Clayey SAND,less than 15%gravel medi dense,moist.dark olive gray,fine to coarse Dark gray Cobbles and boulders to 52.0 ft. Very dark gray Gravelly,silty,clayey SAND, Dense,moist,dark olive gray,fine to coarse,silty c1a)',clumps with fine gravel Silty SAND,less than 15%gravel mediu SM dense (frozen),humid dark grayish bro fine to coarse with occasional yellow- ish brown silt,clumps. Silty clumps with fine g,ravel varved s "It SM clumps 40%fine to coarse subangu1ar t subrounded gravel-dark olive gray. Occasional thin clay seams SM SC SC SM SC SM SC 16 32 18"34 [9f:.))~)~?@ At 48-52 Ft HAH,DDH'--_'--_'--_"--_"--_-'-_-"-_..1.-----'-_-'-_--.:---' Boring No.HD83-Sheet __1_of 3 50 .... ---~ SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT SheetL_of~ Date 3/31 /83 Boring No HD 83-50 (P) Feature Relict Channel Coordinates:N 3233761.2 E 748255.0 Logged by _JEP ,lUill,WMB.,JFBlLEM Angle (from Horizontal)_--,9~O~Ground Elevation 2290.8 Bearing Rock Elevation __----.:==-_ Date Started 3/20/83 Total Depth 119.5 Date Completed ~3LlI:...:2~1!w/,-,8,,-,3L-Ground-Water Elevation-=-=~_ c ~ci III C.-c ..c:.S!0-lII-Zo.::::l:..c:f!!.!:!-II'oLl)'E.c; _C 0.>1II>-lII ..c:0'Ia:I::::l E lii -I-CJ·0'1>0.0 SoH DescriptionIII>.218 o.-c 0 Coc~Ol-E C ::~III (J ~...I(/).:o III ...IlII Clwa:"''''jiio.50~(/)a: C .S! 1U;:E Remarks 2 U;.: ISS DO 4" - LL25 PL15 PIlO Gs 2.70 At 52 Ft.,HAM. CI l'&f~:}:::;;:·:.~n~ h:i=~·tnJi;ii~ LL18 PL14 PI4 G =2.72s LL18 PL14 PI4 Boring No.HD83-Sheet __2_of __3_ 50 Gravelly,silty,clayey SAND,dense to very dense,humid,very dark gray, fine t.o coarse subroundedto subangula gravel silt/clay clumps with fine gravel wit h oeeas·ional·cobbles. Slightly more clay More silt Slightly more gravel. Moist Dark olive gray 8M SM SC SM SC SM SC 48 Sf! 00 }It 23 20 SC 19 16 22 13 17 12 15 14 100 ffDljlllA a f~Jj~{~{m SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet 3~_of ~3_ Date 3/3/83 Boring No HD 83-50 (P) Feature Relict Channel Coordinates:N 323376]2 E 748255.0 Logged by ---JEP,REH,WMB ,JFB ILEM Angle (from Horizontal)90 Ground Elevation 22 90 .B ~ Bearing Rock Elevation _~~~~_ Date Started 3/20/83 Total Depth _l.-1.l..1.;:z9~•.J5 _ Date Completed _34/'-"2_1...../'-'8"'"'3.L..-~Ground·Water Elevation_-_-_-_ LL23 PL16 PI7 ~2FHd0~ Mle 7% !?:.~;t::~:::.~:::=:>:.:fi1 LL20 PU9 PIl Mlc 8% Remarks Refusal c .S! OJ "E QI E;: Ui .5 Gravelly,silty SAND,WITH COBBLES very'dense,moist,dark olive gray, fine to coarse~'subrounded to.subangula gravel Soil Description Slightly more clay .!:! .eOl 0.0 f.!...J CJ SM SC SM GC Clayey,sandy gravel,very dense,humid olivegray,fine to coarse,rour:'-ded to '0 .el!! -CllOl>c:0 QI U ...JQI a: 68 100 2.5" ci QI Zo. QI>-I- 0.'0Ec lUlU00 QI-_lU 0.> E :P lU-00.5 ~0-_c 1I3:::l .El8 a: C .e .S! 'Q.'(; QI > OQl iIi 100"" Silty,clayey sand,20-25%gravel,humi dark olive gray,fine to coarse,sub- angular to subroundedgra.vel,silt-clay clumps with fine gravel Ift!olH--+--+---j--+--/--+BOULDER @ 119.5··-----------1 T.D.=119.5 Ft. 125 Boring No.HD83 -Sheet 3 50 3of _ ..... SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT -._'f Sheet _1_of _2_ Date 3/31/83 .- Boring No HD83-51 eN)Angle (from Horizontal}__--"'-9....0_o Ground Elevation 2,236.7 Feature ReJ ict Channel Bearing -'==:=='-:-,..--___Rock Elevation ~N!.LI£A"___ Coordinates:N 3232725.0 Date Started ---:3:=../!.:c2=1!.:c/8=.3::....Total Depth 98 .5 Ft. E 7472 93.4 Date Completed __~3L/~2~2L/.:::8.:::3 Ground-Water Elevation-=-=.=-::.::-=--_ Logged by.JEP/RLJ;WMB/JFB,LEM- C -=~-°111 C.-a :8 J::.2 111-Zo.==J::l!u IV.2c _<II Ca.m o.e;111>-0 10 -111 :EelID=EI1I -...uci el>0.0 Soil Description 111 Remarks111>~8 <11-o.-a ~..Co !!~E!"'""C..!0=Ec 1110 Sa::0111 -'111 "!:!:!.C:<II iDa.a::'"= 45 ~8 SP SM "6' 8M 8M 60 SM 60 12"SC -12" SM SC .~..... SC Boring No.HD83-Sheet of _2__ 51 SOIL BORING LOG WATANA DEVELOPMENT Sheet_2_01_2 _ Date 3/31/83 SUSITNA JOINT VENTURE Boring No HD83-51 (N) Feature Relic t Channel Coordi nates:N 32 32 72 5 0 E 747293 4 Logged by JEP/RLJ,WMB!lFB.LEM 90°Angle (from Horizontall .:;....::.Ground Elevation __....Z...2....3.u6L..J.7 _ Bearing Rock Elevation J.lIN-/-/.t:\A-;;;-;:;:--;;-;::=-_ Date Started -::.3.:,/=.2=-17/8~3~--_Total Depth •98.5 FT. Date Completed·3/22/83 Ground-Water Elevation_-_-_-_ 0\lOIII c ~ <Ill CE Remarks 2 7ii ..5 8M SC 35 33 22 SM ~11" "'"l 25 SM ~ SM 26 - 45 4SS 4"S" 27 SC 8SS 100/2" 2' 29 67 8.5'ass 100 31 2SS 100 5.5' c ~-°Ii! C."0 .c.2 ID-Za.~::.cl!u,gC _<II CD'""0 10 :Co'5.t;;a.~-CD111::1 EID -l-Ud l:lI>0.0 Soli DescriptionID>gS a.'CI Coc.!!!<11-Ec ~....IDu ~.... !!!.a:en.5 <ll1IlI OG ....ID <:7eniDa.a: SM18SC 100 6 11 20 ISS 100 6 11 2BoringNo.liD8 3-Sheet __2_of51 --- 1 8Sheet__of __ Date3!31/83WATANADEVELOPMENT SOIL BORING LOG SUS/TNA JOINT VENTURE Boring No liD 83-52 (D)Angle (from Horizontall __.....:9:....:0=----Ground Elevation -=22=-5=1~.4-'----_ Feature Relict Channel Bearing Rock Elevation 1931.4 Coordinates:N 3231835.6 Date Started 3/22/83 Total Depth _3~3-d3------- E 747266.9 Date Completed 3/26/83 Ground-Water Elevation _ logged by WMB,.TFB,JE'P,RJ,I,MPB!LEM,DAF .... RemarksSoliDescription 8M 2" ···Jo.i.,;-aJ7SS 100 4" c:~-om Co "CI .co2 m-Ze.;,::.cl!!u.S!c _III m>-01/):2 01a.,;e.~-mm;,Em -l-Oci 01>e.oCD>01 0 lll-e."CI ~..Co l!...IO,,!!._0 11).5 Ec lDUa:om ...I CD CJ!:!:!.ClllIII me.II)a: ~LU~.lf5ss 60 00 I'"'"9 SM 8C 4" - 70 11"SM i'""" I 00'5 1 SM .... .....1 SP SM -29 24 13"SM 29 3 SM 50/9 91l-8M r 55/6 5 8M 68S 70 12"8M47 (ck rag 7 GP GM.... ..... Boring No.HD83-Sheet_--=l~of__8_ 52 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet2__of ~ Date 4/1/S3 Boring No liD S3-52 (D)Angle (from Horizontal)~9,-,,0,--_ Feature Relict Channel Bearing ---- Coordinates:N 323]835 6 Date Started _x3.L./..2..2.L./-"S""'3'--_ E 7471266 9 Date Completed _3u./...2o..l6u.I....S....3L-_ Logged by J.ilMB,lFB,lEE,lU.!,MPB /LEM,DAF Ground Elevation ----4.242~5J..l~4Q..---- Rock Elevation J,1....9t.,;3ul ........=4L-_ Total Depth 333 Ground-Water Elevation --===-_ Remarks Boring No.HDS3-Sheet of --..:8:c..-_ 52 II!ili! I 8M SC 1lII'Il 38S 98 12" 00 ~ 8M 2" '""l-, ~:J -, "V-r ~ '! """!\ 8C II!ili! c ~-do Co 'a ..co2 0-ZD.~=..c G u,£!c;_aI 111>-°sn iD;igtaGta~D.i:Eo -l-Ud c;>Soil Description0>.!!is 1lI-D.og ~..0 0 l!....c..!a:(/).:Ec;00 ....g 0!:!:!.alai GiD.(/)a:0 SM 100 5" SOIL BORING LOG WATANA DEVELOPMENT ... Sheet _3__of --.8..- Date 4/1183 Ground Elevation 2251 .4 Rock Elevation 1931 4 Total Depth 331 _ Ground-Water Elevation _-_-_--,-- - ,.... - .... 100 0 3" 8M 8C -. 8M c .51.. C CD E 2 'lii .E Remarks Boring No.HD83-Sheet 3 52 of 8 SOIL BORING LOG WATANA DEVELOPMENT Sheet_4__of_8_ Date 4/1/83 SUSITNA JOINT VENTURE Boring No HD83-52 CD)Angle (from Horizontal)90° Feature Rel jet Channel Bearing Coordinates:N 3231835 6 Date Started 3/22/83 E 7471266 9 Date Completec;:l _.....34-1...2....6'-/-/....8.....3'--_ Logged by Ii[MB,IEB,IEP,RT,T,MPB/LEM,DAF Ground Elevation 2251.4 Rock Elevation 1931.4 Total Depth 333 Ground-Water Elevation-=-=-'-_ 001 .05'0 59 -I53 54! 8M ""'" ~ 55 t -! 56 .., """57 -1 58 ""'! ""'"51 8M """I 52 """!! -=~.~&'E.".=:.2 0-CD-:1=.=:l!u_c:_ill CD>'°on ~D1amCl.t:-CD11:1:1 ECD _.... °d 1'1>Cl.o Soil DescriptionCD>g8 CI."c:oco!!a-Ec:~..CDu l!!.... a:0.5 OCD ....CD 0!!:!.ill III iDCI.a:(I) 48 8M Boring No.HD83-Sheet ---,4,--_of 8 52 -SOIL BORING LOG WATANA DEVELOPMENT Sheet _5_of -S....- Date 4/1/83 SUSITNA JOINT VENTURE RemarksSoilDescription 8M 8M CL 8M SC SP 8M 8W -SM 10"8M j- 00/8"8M 4" 5.5 ' 100/.5" 4" CD-1i~SCDlIIl-"'.:: ~-_c 1II='~8a: RD83 52 CD)·90°2251.4BoringNo-Angle (from Horlzontal).::...;;.____Ground Elevation _ Feature Relict Channel Bearing --Rock Elevation ---1931.4 Coordinates:N 3231835 6 Date Started __-:3,.:/..-::2:-:2;.:./.,-;8:--:3:-Total Depth 333 _ E 7471266 9 Date Completed 3/26/83 Ground-Water Elevation-==-_ Logged by 'WNB,liB,liP,~_1 ,MPB ILEM,DAF -. - .... - Boring No_RD8 3-Sheet __5_of _8::...-_ 52 _-_1 SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_6_of lL- Date 4/1/83 - Boring No HD83-52 CD)Angle (from Horizontal)--=-9_0_o Ground Elevation __..,,2""2""5'-":1'-'0'-'-'4'----_ Feature Rel ic t Channel Bearing Rock Elevation __--J.l.::t9~3.Ll....."'I4~--- Coordinates:N 3231835 6 Date Started 3/22/83 Total Depth 33~3__""--- E 7471266 9 Date Completed 3/26/83 Ground-Water Elevation _ Logged by WMB t .TER t ,lEE,&1..1 ,MPR ILEM,DAF - - - -I Remarks 8M 8M 8M SP SM H-~-i-.........-'-f----'-~-H-----'-~+----+-_H__H__H_.,.__'_-,-t---'-'-"'-l 8F 8M 1-H~1ooflJi'Hi 2" 00/ 2" 00/3" 6" 100/a I" c ~-oeD c·'CI =~eD-ZQ,::::11=.cl!u..5!c _Ill CD>-0 10 :E0lQ,~-CDQ,G 11:1::::11 EID _f-<.:I Q l2I>Q,o Soil DescriptionID>.2iS Q,'CI Coco!!111-Ec :1:..lDu l!...Ia:1:1).5 OlD ...lID CJ!!.GllI iiiQ,a:1:1) 8M Boring NoJlD83-Sheet __6_of --.;8L-_ 52 .- .... SOIL BORING LOG WATANA DEVELOPMENT Sheet -l-of .-8...- Date 411183 sus/rNA JO/NT VENTURE Boring No HD83-52(D)'Angle (from Horizontall __---'-9_0_o _ Feature Relic t Channel Bearing Coordinates:N.3231835.6 Date Started .L3L-12 2J-1""8....3__ E 7471266 9 Date Completed ....-l.3J-1 2.l.!.6L-'/8~3.L-__ Logged by 111MB,lEB,IEP,BT,I ,MFB ILEM,DAP Ground Elevation 2_2_5_1_._4 _ Rock Elevation ----~l...;;9h;3l-..11..........4_-- Total Depth 333 Ground-Water Elevation _ Remarks .§ fti C CDe 2 'lii..: 8M GP GM c ~-°CD CO 'l::I s;o CD-Zo.::1=s:!u.2c --CD>-0..,:iiI:»ai o.c:-QJlD:::I EQJ -~(,)d ell>0.0 Soil Description.-.!.!gS 111-o.'l::I ~-Co !..4 (I)":Ec CDua:OCD ..4QJ CJlB---iDo.a:(I) ,- -~/ - - Boring NcJID83-Sheet -'.7__of 8 52 CI SUS/TNA JO/NT VENTURE GEOLOGIC LOG WATANA DEVELOPMENT Sheet ---B.--of ~ Date 4/1/83 - Boring No HD83-52 (D)Angle (from Horizontal)_----"'9'-"O'-o Ground Elevation 2251.4 Feature Eel fer Channel Bearing Rock Elevation 19..31 -"'4=----__ Coordinates:N 3231835 6 Date Started 3...,.1.....2...20.4I'-'oS...3.L-__Overburden Thickness ---3 2 0 0'--__ E 7471266.9 Date Completed 3;LJ/L.;2w6""!f-J8~3 Ground-Water Elevation_==-_ Core Sizes _--'NX......._~Total Depth 333 Logged by WMB,.IFB,.JEP,RI..I,MPBl Graphic log C !-,=02 >-ea.Cl :::l .a g'.0 UCD>'0 g ....oo!!-5 2 .. !:!:!.iii .... :::::i 3 6 9 12 Classification and Physical Description cu~....5!:c:0 CD iii..aQ,Q e cIIICf..::iI CD<;'a::z e Remarks Ii ;i l<.5ud0UJIIIS-.- ..-l-- - - - .., ! i - Boring NoJID83-Sheet 8 of _8__ 52 n- SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT -..;.-._'1 Sheet_1_of _5_ Date 4/1/83 .- .- 90 0 Boring No HD83-53(A)Angle (from Horizontall _ Feature Relict Channel Bearing Coordinates:N Date Started ....3""'/'-"2....8.....'.....,8"'3""--__ E Date Completed 4-'-'/'--'8"-'/'-'8~3"--__ Logged by 101MB,JEB,RT,J,MPB"TEP/LEM --_...~-_.--- Ground Elevation 2248.a Rock Elevation _ Total Depth 212.0 Ground·Water Elevation....:-=.:-=.:-=-_ 5 Remarks Boring No.HD83-Sheet 1 of.53 ------ 8C 8M 8C 2040 l8 n GC 50 - - - ~I ~-°CD 'E.00CD-Za.::II::::~l!!().5!c _Ill '3.';a.~CD=--0..,-CD ::E aIID::II ECD -I-(,).1:11>a.o Soil DescriptionCD>.2'B a.00 0 Co",-~..e..lF-"C,!!0.!:Ec CDu ,w a:~'"OCD ..I CD c:J !0 iDa.a: ·1 .I"- .- \ SUSITNA JOINT VENTURE SOl L BORI NG LOG WATANA DEVELOPMENT Sheet_2_of_5_ Date 4/1/83 - - - Remarks co:::: lit CCD E 2 'lii .5 Ground Elevation __-,-~2~2~4~8~.O!!--__ Rock Elevation -=::::-----=-_ Total Depth 212 •0 Ground-Water Elevation -=='--_ Soil Description GC sc SC 'tl s:.l!!-IIICIl>CoCDC) ..I CD II: i:.:1=0.., Uc:i ~..OCDiiQ. 7 8 15 14 13 9 ""!! I!!II!!lI 10 SC lIIil\1 11 ~ 12 °CDZQ. ~~ Q.-aEc lit lit f/J ~0-_C tD:I .218 II: Boring No HD83-53 (A)Angle (from Horizontal)-.:::9-=0'-o _ Feature Relic t Channel Bearing Coordinates:N Date Started ---"3'-l./~2'""8<J./__'8"-'3"--_ E Date Completed __...:.:4.£../..:::8.L1..:::8.=:3 _ Logged by WMB »JFB ,RLJ »MPH »JEP /LEM Boring No.HD8 3-Sheet _=-2_of --=5=--_ 53 '",31 SUS/TNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet _3_of _5_ Date 4/1183 -- Boring No HD83-53(A)Angle (from Horizontal)--=-9...::.0_o Ground Elevation 22/16.0 Feature Relict Channel Bearing Rock Elevation _ Coordinates:N Date Started ....;3~/'-'2=-8;:,./'-8;:,.3~__Total Depth 212.0 E Date Completed -4/8/83 Ground-Water Elevation_-_-_-_ logged by WMB t JEB t RLJ t MFB t JEP ILEM .HD83-Bormg No.Sheet of _ 53 8M 8C GC GW 8M SC 24 18 17 20 21 19 22 23 c C ~-om 'C.'tlI ! .e.2 m-Zo.==.cl!!u CIS_Ill Ca._C o.~m>-0",-m ::El:lIm=cm -....t,).l:lI>0.0 Soil Description G>Remarksm>.218 o.'tlI 0 Co E....co!!1lI-~...mu l!-'a:en.5 cc o-m -'m CJ 2!:!!."llll jijo.a:'liJ .5 16 GC,- - ..... ..... .... - --...., SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT ....-._. Sheet __4_01_5_ Date 4/14/83 - Boring No HD83-53 (A)Angle (from Horizontal)90° Feature Bel ict Channel Bearing Coordinates:N Date Started 3/28/83 (,E Date Completed _-----"'4~/.....84-/.....8'-3L..----_ Logged by WMB,,TFB ,BT..T,MPB ,,TEP IT.EM Ground Elevation __224",8"'-L""'O _ Rock Elevation _ Total Depth 212 a Ground-Water Elevation_-..:..-:..:.=--_ - 5 c -C-ci CD 'E.oS!:~1 ~--g OJ.e.S!D-Zc,:::I:::.el!!u.S!c _ca CD>-OlD ::2 C1l Ca-;c,e -DID:::I ECD -l-°ci CI>c,o Soil Description GI RemarksG1>.2iS 11I-c,-g ~..Co l!!-'EQ,!!!en.5 Ec Du .5!:!!.a:caca OD -'CD Cl -II)iDC,a:III .5 -" -] 25 II!Il!iI I 26 Boring No.HD83-Sheet 4 of53--- --- SUSITNA JOINT VENTURE SOIL BORING LOG WATANA DEVELOPMENT Sheet_5_Of_5_ Date 4/18/83 Boring No HD83-53 (A)Angle (from Horizontal)=-9..=.O_o _ Feature Relict Channel Bearing Coordinates:N Date Started --'3=..1...2",8.LI-"S""3'--_ E Date Completed __:::!.4L/8~/8~3>L.-_ Logged by WMB,TEB,BTIoT,MPH,TEP!LEM Ground Elevation 2248.° Rock Elevation ----"==--_ Total Depth 21 2 • 0 Ground·Water Elevation-=-",,-""-'--_ -! ,.,.. .- ""'"I c C-Olli c·-a .51 z:.0 :1_1II-zo.:===1II u -; a:;Sc:Q.~!1.~0.,.Q~:E CI C11:\:=Ee °0 c>0.0 Soli Description CD RemarksCD>g8 Q.-a Eo!1.\IlI-~...ClIO l!....en.!:Ec ....g := !:!!.a:_\Ill Olll CI ... (/)iDa.a:.'In .5 27 Boring No.HD83-Sheet __5_of __5_ 53 APPENDIX D -LABORATORY TESTING 1.PROCEDURES 1.1 Sample and Control Processing 1.2 Particle Size Analysis 1.3 Atterberg Limits 1.4 Moisture Contents 1.5 Organic Content 1.6 Specific Gravity 1.7 Compaction Tests 1.8 Visual Classification 2.LAB TEST SUMMARIES 2.1 River Channel 2.2 Relict Channel 3.GRADATION CURVES 3.1 River Channel 3.1.1 Main Dam 3.1.2 Upstream Cofferdam 3.1.3 Downstream Cofferdam 3.1.4 Portals 3.2 Relict Channel - APPENDIX D LABORATORY TESTING As part of the Winter 1983 Field Drilling Program,Harza-Eb~~co estab- lished and operated a field soils laboratory at the Watana site. Routine index property and classification tests were performed on soil samples taken during the Drilling Exploration Program. Soil index tests were performed to classify soils and determine their grain size distributions,plasticity indices,in-s itu moisture contents,organic contents,specific gravity,and compaction character- istics.Also,visual descriptions of soils were made. The procedures employed in the laboratory testing program were gener- ally in accordance with those suggested by the American Society of Testing and Materials (ASTM).When deviations from ASTM recommended procedures were made,they were noted on the test forms.The specific test procedures and variations from ASTM methods are discussed in the following sections: 1.PROCEDURES 1.1 Sample and Control Processing Samples collected during each shift of drilling were inventoried and recorded on the sample test schedule and inventory forms.The selected soil samples were than prepared for testing.Preparation of samples required splitting with a mechanical splitter to obtain representative portions for testing.Visual classifications were performed and the D-l results were recorded on the appropriate sheets thus starting the docu- mentation cycle. The untested portions of those samples used»and the samples not test- ed,were transferred to the storage cage for future use»as necessary. An accurate record of the stored samples with precise locations was kept to facilitate relocating samples for either further testing or visual examinations.Upon completion of each test,the tested portion of samples were passed through a 3/4-inch sieve to separate selected materials finer than 3/4-inch sieve.This material was used for back- filling of drill holes. 1.2 Particle Size Analyses Gradation analysis (sieve and hydrometer tests)was performed on selected soil samples,based on ASTM 0422-63 test procedures.All bulk samples collected from the Hammer Drill Cyclone used for sieve analysis met the minimum ASTM weight requirements.However»the majority of soil samples obtained with split-spoon sampler were usually smaller than this minimum weight.Whenever a smaller than ASTM recommended weight sample was used for testing,it was noted on the test data sheet. Because the hammer drill uses a diesel pile-driver hammer to penetrate the soil,thus breaking boulders,cobbles and gravel into smaller pieces as the hole is advanced»the soil samples obtained have a high percentage of mechanically fractured materials.This percentage of fractured soils retained on the 3/411 sieve were recorded on the test data sheet so that the effect of this fractured material on the grain size distribution could be accounted for. D-2 - .... 1.3 Atterberg Limits (Liquid and Plastic Limits) The classification of samples containing fine grained soils was deter- mined by performing Atterberg Limit Tests.The liquid and plastic limits were determined in accordance with ASTM 0423-66 and D424-59 test procedures,respect [ve ly •. The soil samples tested for plasticity indices were prepared utilizing two different methods,dry or wet method ,ASTM recommends "dry pre- paration of soil samples for grain-size analysis and determinat ion of soil constants"(ASTM 0421-58).In this method of sample preparat ion, the soil sample was air-dried and then sieved through a No.40 screen to obtain the minus 1F40 sample fraction for Atterberg Limit Indices Testings. In the wet method of preparation,the soil sample was first soaked 1.n water for 12 hours and then washed through a No,40 sieve.Both methods of sample preparation have been used at the Watana Site.The wet method was normally used for soil samples with large clay and silt clumps Which could not be early processed using the dry method, 1.4 Moisture Content ..... Moisture D22l6-71 content tests test procedure were to performed in accordance evaluate the water content with of the the ASTM soils encountered. Moisture contents were determined for most soil samples obtained with split-spoon samplers,and on those bulk samples Which were secured in plastic bags.No moisture content tests were performed on bulk samples kept in c19t~bags. D-3 1.5 Organic Content The organic contents of selected samples were determined by the I1stand~ ard method of testing for organic content of soils"(State of Alaska, 1980),also known as the organic ignition test.The samples tested were oven-dried for 24·hours at a temperature of 10S"C and the dry weight recorded.The samples were then weighed to the nearest 0.01 gram and placed in a tared crucible.The crucible containing the sample was then placed in a muffle furnace at a temperature of 950"C +50"e until all organic matter was combusted,usually about two hours.The samples,were then cooled to room temperature,weighed,and the percent of weight loss calculated and presented as the amount of organic materials. 1.6 Specific Gravity Selected samples were tested to determine the specific gravity,Gs ' of their soil constituents.Specific gravity tests were periodically performed to establish a representative range.The ASTM D854-58 test method was used for conducting specific gravity determinations. 1.7 Compaction Tests A limited quantity of standard and modified proctor tests were perform- ed to establish typical compaction characteristics of selected samples from the relict channel/borrow area.ASTM D698 and D1557-78 test pro- cedures were used for the standard and modified proctor tests,respect- ively. D-4 - - -ii, ,..... ! ..... r I - 1.8 Visual Classification Visual procedures,based on ASTM D2488--69 test method,were performed on the majority of soil samples to assist with the soil classifica- tions.Visual descriptions of soils such as color,dry strength, "toughness,dilatancy and roundness were recorded on each test data sheet. A summary of the results of laboratory testing performed during the river channel and relict channel testing program are presented in the lab test summary sheets Which follow.Interpretation of the laboratory gradation data is presented in a set of curves at the back of this appendix • D-5 ,... 2.LAB TEST SUMMARIES -I ~r . I l 2.1 RIVER CHANNEL ! BORI~IG NO. HD83-10 d .....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«W I z u'"LIMITS ~ONTEN_'"SIEVE ANAlYSIS (%)IwILl0....>-Oc;:.....-':I:-W;;;'"C-a.,w ......U:::lI'l~COBBLE GRAVEL SAND SILT/CLAY ao:w ...L.l.P.L.PI.Wc (%)~:'ll~a..C-W -«0"'",««>-w W Z ....._>-ww lI'l cr.,....o~:::::lU ...J:~... 1 l3ULK 4-5 GM N/A 46.2 39.7 14.1 ----- 2 l3ULK 8-10 -N/A -- - -----, ~ULK 14-15 GP-G'N/A 61.9 30.0 8.1 ----3 - 4 BULK 20-22 GP-G N/A 59.2 33.2 7.6 --- - - 5 B1JLK 23-27 -N/A --- ---- - 6 ~ULK 30-31 Sl-1 N/A 35.1 48.9 16.0 ----- ~7 Bl.JI1~34-36 GW N/A 58.2 38.3 3.5 -- -- - 8 BULl<40-42 -N/A ---- --- - 9 BULI<46-48 GW-G'N/A 72.7 21.2 6.1 ---- - 10 BULl<50-52 GP-G N/A 56.7 37.0 6.3 ---- - I"11 Bl[JlJ<55-57 GW-G N/A 57.0 37.2 5.8 - -- - - t'12 BULl'60-65 GW N/A 60.6 35.8 3.6 --- - - 13 Bl[JlJ<65-70 -N/A ---- ---- I'14 BULl<70-75 GW-G N/A 61.6 31.0 7.4 -- -- - 15 BlJI.J<75-80 GP-G N/A 56.1 33.3 10.6 ----- 16 BlJLI<80-85 G'W--G N/A 45.8 45.3 8.8 -- --- I:17 BlJLF 85-90 -N/A ------- - 18 Bl.JLI'90-95 GP-G NjA 70./LU.l 9.2 - - -- - t ~Remarks: 0 ~ ...... J J J 1 I J .- LA.B TEST SUMMARY rJoring No.HD83-10 ~sitna Hydroelectric Project SUS/TNA JOINT VENTURE BORING NO.HD83-11 6 ......,~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«wz~t;;SIEVE ANALYSIS [%)I LIMITS !cONTENTww0....>-O~............:c-!:!;!iii Vl ~w~CL.CL.w ~~....1I'l6 COBBLE GRAVEL SAND SILT/CLAY L.L.P.L.p.1.Wc (%)~~Q.Q.w -«o ~VI ««>-Ww 5d~>-ww VI Vl ....o~:c ~.... 1 BUil<10-15 -N/A -------- 2 BI.JIl<15-18 -N/A -------- 3 BlJLI<20-25 GW-Q N/A 60.1 31.1 8.8 --- -- 4 BlJLI<25-30 SP-9 N/A 30.1 62.1 7.8 --- -- 5 BULF 32-35 -N/A -- - ----- I 6 Bl.JLF 35-40 -NfA -- - ----- 7 BllU 40-43 -N/A - - - ----- 8 B1[U:"f<51-55 GP-G N/A 64.7 28.8 6.5 - -- -- I 9 BULl<55-60 -N/A ------- - I I t I L Remarks: I - .... J 1 1 J J J j 1 LAB TEST SUMMARY ~Joring No.HD83-11 Susitna Hydroelectric Project SUSITNA JOINT VENTURE t :BORING NO. HD83-12 : d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~~WZ'::dt;;SIEVE ANAlYSIS (%l I LIMITS !cONTENTwILl0....>-00.:...J --'x-wu;VJa..a..w ~~Li:VJ O COBBLE GRAVEL SAND SILT/CLAY 0.:w~U.p.l.p.1.We ("10)~~a..a..w -c:(O~VJ c:(c:(>-Ww Z--'>-ww VJ VJ ~o~::l U i=X :E.~ : 1 BUll<10-15 -N/A - ----- -- 2 BT.JI.J<15-20 -N/A ------- - 3 Brll 20-25 GP-{l N/A 54.5 37.0 8.5 ---- - 4 BUI.J<25-30 GP-Gr N/A 70.4 22.9 6.7 - -- -- 5 Btll 30-35 -N/A - - ----- - t 6 BlJLI<35-40 Gw-G N/A 51.0 41.9 7.1 -- -- - 7 Btn 40-45 -N/A - ---- -- -i 8 BIJLF 45-50 -N/A - ---- - - - 9 Bfn 50-55 -N/A - ----- - - 10 B1JLF 55-60 -N/A - - ----- - I' 11 BULF.65-70 -N/A - - ---- - - t:12 BUil 70-73 GP-G N/A 56.9 33.8 9'.3 --- - - . 13 BUU 75-76 -N/A - -- - ---- I t f l Remarks: , ..... 1 1 J J ~ I 1 J J 1 .LAB TEST SUMMARY noring No.HD83-12 Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO.HD83-13 0 .,.jl~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~~Wzul- I LIMITS CONTEN_VI SIEVE ANALYSIS (%)w w 0l4.>-Oar:..........I-wii)ena..a......1-ii:Vl~COBBLE GRAVEL SAND SILT/CLAY ar:wI-L.L.P.L.p.1.Wcl%l~~~a..W -~o I-en ~~>-WW Z ....._>-ww en VI I-o~~Ul-I ~I- 1 [BULK 10-15 -NjA -------- 2 IBULI<15-20 SP NjA 44.7 52.0 3.3 ----- 3 Bl~20-25 -NjA - ------ - 4 BULl<25-30 GP-Qi NjA 54.1 35.8 10.1 '--- -- 5 BlJI.1<30-35 sp-sr-NjA 46.0 48.6 5.4 ----- 6 BULl<35-40 -NjA --- -- --- 7 BULK 40-42 -NjA --,-- ---- 8 BULK 45-57 -NjA - -- ---- - 9 BULI<50-52 -NjA - ------ - I;10 BULK 55-57 G~NjA 52.6 38.9 8.5 - - -- - 11 BUI...R 60-62 -NjA - ----- - - 12 BT.JLI<65-67 -NjA - --- --- - 13 BT..1I1'70-72 GP-Q NjA 63.2 27.5 9.3 - -- -- ,- I Remarks: l 1 1 J J 1 1 I ~ 1 1 I 1 SUS/TNA JOINT VENTURE lAB TEST SUMMARY...., .toring No.HD83-13 Susitna Hydroelectric Project-------------------------- - BORING NO. RD83 14 d ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~c(~z ':dVl SIEVE ANAlYS IS (%)I LIMITS 1c0NTENww0....>Oc.:........J:-Wu;1I)ao:wI-Q..Q..w ~~i:i:Vl O COBBLE GRAVEL SAND SILT/ClAY L.l.P.l.p.1.Wc (%)~~Q..Q..W -«o ~Vl c(c(>wW Z ...._>ww Vl Vl I-0 ....~Ul-I ~I- 1 l3uLK 10-15 N/A - --- - ---- 2 SULK 15-20 -N/A ------- - 3 BULK 20-25 GW N/A 70.0 27.8 2.2 --- - - 4 SULK 25-30 Gw-GM N/A 60.0 34.4 5.6 ----- 5 BlLK 31-32 GW N/A 60.0 35.1 4.9 ----- I I I I I I I I L Remarks:. 1 - 1 1 J J I j I J 1 LAB TEST SUMMARY..... loring No.RD83-1Lf Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. HnRi.., (j ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~~Wz~tn SIEVE ANALYSIS (%)I LIMITS fcONTENlww0....:>-00<:.........~-~i:iionQ.Q.w ~~....lIl a COBBLE GRAVEL·SAND SILT/CLAY ~~tn l.L.P.l.PI.Wc(%l~~Q.Q.W -~~~:>-WW z ....._:>-ww III 1Il~o~=:lUI-~~I- 1 BUU 6-8 -N/A - --- --- - 2 BfJI1 10-12 GW N/A 55.5 40.0 4.5 ----- 3 BUll 14-16 GW N/A 64.7 31.1 4.2 - -- - - 4 BlJIl 21-23 GW N/A - --.--- - - 5 BW 26-28 GP-Gl N/A 68.0 24.2 7.8 - -- - - I I I I Remarks: 1 1 1 1 1 1 1 J J 1 1 1 1 1 LAB TEST SUMMARY.... 1 loring No.HD83-15 Susitna Hydroelectric Project SUSITNA JOINT VENTURE - ! J BORING NO.HD83-16 "'I~PARTICLE SIZE ANALYSIS REMARKS6$:i<C(w ATTERBERG MOtST.z ~t:;SIEVE ANAlYStS (%)I LIMITS rCONTEN'j w w 0 ....>-00'...-'::I:-winV') 0'w~Q..Q..w ~~iL:V1 0 COBBLE GRAVEL SAND SILT/CLAY L.L.p.L.p.1.Wc (%)~~Q..Q..w -c{o ~trl<C(<C(>-Ww z ....>-Ww V'I V1 ~o~=>ui=::I:~~ J 1 BULK 8-10 -N/A ----- -- - 2 BULK 12-15 N/A -- --- ---) 3 BULK 15-18 GW N/A 70.4 24.8 4.8 ---- - .. 1 1 1, 1 1 1 1 1 1 i 1 1 1 Remarks: 1 LAB TEST SUMMARY ,"'oring No.HD83-16 dusitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. ;:'nR ~_1 7 d ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~<O(~z ~II)I LIMITS IcONTENlwILl0.....>-SIEVE ANALYSIS (%)o eo:--'--'r-WLilLfla..Q..w 1-1-~Lfl~COBBLE GRAVEL SAND SILT/CLAY eo:wI-L.L Pl.p.1.Wc(%l~~Q..Q..W -<0(o I-Lfl <0(<0(>-WW 5di=>-ww II)II)I-o~r ~I- 1 BULl<16-18 SP N/A 47.8 49.2 3.0 ----- 2 BtlLI<20-22 GP-G N/A 65.5 28.6 5.9 --- -- 3 BUll 25-28 -N/A - ------ - " 4 BtU 35-37 SP-Sf N/A 37.7 56.1 6.2 -- -- - 5 BtU 32-35 -N/A - - -- --- - 6 BUIl<40-42 GW N/A 83.3 15.7 1.0 ----- 7 BtU 46-48 SP N/A 41.1 56.5 2.3 - --- - 8 BUU 53-55 GW N/A 79.6 18.6 1.8 -- -- - 9 BtJLF 55-58 -N/A - -- - ---- L I I Remarks: ..... i i J I 1 1 1 1 1 1 1 1 1 1 1 LAB TEST SUMMARY noring No.HD83-17 $usitna Hydroelectric Project SUS/TNA JOINT VENTURE ,BORING NO. HD83-18 0 §I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wzl:::!tn SIEVE ANAlYSIS (%)I LIMITS CONTENw~I ou..>- 00/:-'-,::c-winV') 0-~w 1-1-U:V')~COBBLE GRAVEL SAND SILT/CLAY 0/:wI-LL.P.L.p.1.Wc[%l~'a..o..W -«o I-V') ««>-W W Z -'_>-wwV')crt l-ou..::lUI-::C~I- I 1 13ULK 6-7 GP-GM 3.6 59.2 31.4 5.8 ----- 2 13ULK 10-12 GM 0.0 49.4 35.3 15.3 ---- - 3 ~UI.K 16-17 8M 0.0 39.5 45.5 15.5 ----- 4 BtJLK 20-21 GW-GIv.0.0 55.7 36.3 8.0 '---- - 5 BULK 23-24 SW-ffi./0.0 33.4 55.1 11.5 ----- l . I I l Remarks: J J J .1 J ,.,.. J 1 1 1 SUSITNA JOINT VENTURE fila'"LAB TEST SUMMARY ~ 30ring No.HD83-18 Susitna Hydroelectric Project ,,-,------_._--_.._..--------------------- 1 1 J "IF"" l 1 J 1 1 I 1 1 1 1 1 1 1 1 BORING NO. l-m~':\_1 Q d ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«wz~lii I LIMITS .cONTENww0....>-SIEVE ANAlYSIS ("!o)00:........:I:-wijiV') Q..o..w 1-1- ii:Vl 3 COBBLE GRAVEL SAND SILT/CLAY 0:wI-L.L.P.L.PI.We ("/,,1~~o..o..W -«o I-VI ««>-WW z ....>-w wVIVII-0 ....;:)U~:I:~I- 1 BuLK 14-15 GP 0.0 56.8 42.4 0.8 ---- - 2 aULK 19-20 -0.0 ------ -- 3 BULK 27-28 GW 0.0 68.3 28.5 3.2 ---- - 4 aULK 31-32 -0.0 ------- - 5 l3ULK 37-38 SP 0.0 39.0 59.0 2.0 --- -- 6 ~41-42 -0.0 - ----- - - 7 IBULK 46-47 SP 0.0 9.3 88.3 2.4 ---- - 8 lBULI<51-52 SP 0.0 5.5 92.3 2.2 -- -- - 9 lBULK 60-61 SP-S1"0.0 35.3 59.5 5.2 --- - - 10 iBULK 65-66 -0.0 --- - --- - 11 BULl<67-68 GW 0.0 54.8 41.2 4.0 - -- - - 12 BUI.J<71-72 GP 0.0 74.9 24.5 0.6 --- - - 13 BillJ<------- - - - ,- 14 BULl<77-78 -0.0 ------ - - 15 BUI.J<80-81 -0.0 -- -- - --- Remarks: LAB TEST SUMMARY-'orin 9.No..HD83-19 Susitna Hydroelectric Project 11 SUSITNA JOINT VENTURE i I BORING NO. HD83-20 --- ....J~PARTICLE SIZE ANALYSIS REMARKS0~oc(w ATTERBERG MOIST.z ':dt;I LIMITS CONTENl 1 w LU 0 ....>-SIEVE ANAlYSIS (%)-0 co:........I-wii5 rn "-"-w 1-1-;o:rn O COBBLE GRAVEL SAND SILT/CLAY ~~t;L.L.P.l.P.L Wc (%)~~"-,,-LU -oc(oc(oc(>w LU 5di=>ww on rn I-0 ....I ~I- 1 1 13ULK 10-15 GW N/A 78.5 20.9 0.6 --- - - 2 BULK 15-20 -N/A -- --- --- 1 3 13ULK 20-27 GW N/A 77.2 20.2 2.6 ---- - 1 4 l3uLK 30-33 -N/A --- --- -- ~ULK 33-38 GW N/A 55.9 35.9 8.2 -- --5 - L 6 BULK 42-45 SP 33.5 62.8 3.9 -- -- - - 1 7 BULK 46-48 GW N/A 49.2 47.9 2.9 - ---- ~ULK 54-55 N/A - -8 ------- ~9 SULK 57-60 GW N/A 73.3 25.1 106 ---- - 10 ~ULK 61-65 GW N/A 64.6 31.3 4.3 --- -- 1 11 SULI<66-68 GM N/A 36.0 30.5 33.5 ----- 1 12 iBuLI<70-75 -N/A ----- -- - 1 L L L L L Remarks: L LAB TEST SUMMARY p;oring No.HD83-20 ~usitna Hydroelectric Project SUSITNA JOINT VENTURE .....,-------------------------------, (j ....I~PARTICLE SIZE ANALYStS ATTERBERG MOIST.REMARKS~«wZ~t;;I LIMITS iCONTENww0....>-SIEVE ANAlYSIS (%)001:........r-win'"Q..Q..w 1-1-~.,,~COBBLE'GRAVEL SAND SILT/CLAY 01:wI-L.L.Pl.p.1.Wc{%l~~Q.Q..w -«01-." ««>-ww Z ...._>-Ww .""'1-o!::.~Ul-r ~I- 1 Bll.J<1-2 8M N/A 7.5 74.6 17.9 ----- 2 BULK 6-7 -N/A -------- 3 BULK 10-12 -N/A ------ -- 4 BULK 15-18 G~N/A 61.1 33.2 5.7 .---- - 5 BULK 20-25 GW N/A 74.7 23.9 1.4 - --- - 6 BULK 26-28 GW N/A 60.6 29.6 9.8 - - -- - 7 BULK 30-33 SP N/A 31.5 66.3 2.2 -- -- - 8 BULK 36-38 -N/A ----- --- 9 BULK 40-45 SP N/A 32.4 63.4 4.2 - ---- 10 BULK 45-50 GP N/A 51.8 43.8 4.4 ----- 11 BULK 50-55 -N/A ------- - 12 BULK 55-60 SP N/A 19.7 76.7 3.6 --- - - 13 BULK 60-65 GP N/A 59.5 32.5 9.0 ---- - I""" .-1 BORING NO.HD83-21 J 1 1 1 ! 1 1 J 1 1 1 1 1 1 1 Remarks: 1--------------------------------------......1 ·LAB TEST SUMMARY -loring No.HD83-21 ~usitna Hydroelectric Project SUSITNA JOINT VENTURE .'!""""--------------------------....., 6 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~c(wz~ln ,LIMITS CONTEN'w \J..'Ou..>SIEVE ANALYSIS (%)0Cl:~~I-wii'ill'lQ..Q..W ~~U:lI'ltj COBBLE GRAVEL SAND SILT/CLAY Cl:w~L.L.P.l.P.1.Wc (%)~~Q..Q..W -c(O~1I'l c(c(>w W z~>Ww II'l 1I'l~o~::JU~I~~ 1 SULK 3-5 GP N/A 74.5 23.6 1.9 ----- 2 &JLK 5-8 GW N/A 72.7 23.8 3.5 ----- 3 ~ULK 10-17 -N/A ------- - 4 l3ULK 21-23 GW-Glv:N/A 58.5 36.3 5.2 ----- 5 IBULK 25-28 GW N/A 57.8 39.2 3.0 --- -- 6 BULK JU-j4 N/A 67.~--ZO.T 6.0 -- --~........ 7 BULK 35-38 GW N/A 61.2 34.2 4.6 -- --- 8 IBULK 40-42 -N/A - - -- ---- 9 BULK 45-48 SP N/A 27.7 69.0 3.3 ----- 10 BULK 50-53 -N/A ---- - - -- 11 BULl<54-58 GW NjA 66.1 31.0 2.9 --- -- 12 IBUW 61.-6<-0 ~/A - -- - - -- - --r:J IJ:SUUI 0;:)'-01 l.'if .t1.00."':1:L;;:).'::J :J.1 - - - - -~...'""" 14 BULl<70-72 GW N/A 59.1 37.1 3.8 - - --- 15 BIn 74-78 -N/A - - - - --- - 16 BULl<80-83 -N/A ---- -- - - .if IJ:SUUI ts~-ts I LVfi o'::J •.l ~.j.U I.~-- - -'-'...~ 1 ~ 1 J .t 1 1 1 L, 1 Remarks: 1--------------------------------..... 1 1 J BORING NO.HD83-22 1 J 1 LAB TEST SUMMARY "Soring No.HD83-22 'Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. HD83-23 <« 0 ....I:E PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~.c(wz':,dtn I LIMITS ~ONTENT w w 0"'>SIEVE ANALYSIS (%)o eo::--'--':::c-wijil/) Q..Q..w 1-1-U::If)~COBBLE GRAVEL SAND SILT/CLAY eo::wI-u.P.L.P.I Wc (%):E :EQ..Q..W -.c(o I-If) .c(«>w W §ui=>w w If)If)I-o~:::c :E l- I ~ULK 2-4 -N/A - ------ - 2 ~ULK 5-8 Gw-G:N/A 66.7 28.1 5.2 --- - - 3 !BULK 10-13 GW~N/A 57.7 34.7 7.6 - ---- 4 ~lJLK 15-18 ,...N/A ----- -- - 5 BlILK 21-24 GW N/A 61.5 34.5 4.0 ----- 6 BllI..I<25-28 GM N/A 47.4 38.4 14.2 -- -- - 7 BULK 32-34 SP N/A 40.1 55.4 4.5 ---- - .8 BULK 39-41 -N/A ---- --- - 9 BULK 45-48 8M N/A 43.3 44.1 12.6 - - -- - 10 BULK 51-53 Gw-Q-N/A 60.1 33.7 6.2 -- -- - 11 BlJI.J<55-58 -N/A - - - --- -- 12 BULI<61-65 -N/A --- - ---- 13 BlJI.J<67-69 8M N/A 34.8 50.6 14.6 - -- - - L Remarks: 1 J j 1 1 1 1 1 1 1 i 1 1 1 I 1 1 1 LAB TEST SUMMARY noring No.HD83-23 tiusitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. HD83 24 (j ~l~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«(wz'.:db;SIEVE ANALYSIS (%l I LIMITS fcONTENTww0....>Oel'-'....r-wiij<flQ..Q..w ~~ii:<fl O COBBLE GRAVEL SAND SILT/CLAY 0'w~L.L.P.L.P.1.Wcl%l~~Q..Q..w -«(o ~Vl «(«>Ww z ....>ww Vl <fl ~o~:::lU~r~~ 1 13ur.J<8-10 GW N/A 73.4 22.1 4.5 -- -- - lA ~ur.J<10-12 GP-GM N/A 67'.3 25.4 7.3 - ---- 2 ~ULK 12-15 GP-GM N/A 61.8 28.7 9.5 - ---- - Remarks: 0 I.,. L I,.... L I """ L L 1 1 1 I' 1 t..... 1 1 1 1 SUSITNA JOINT VENTURE LAB TEST SUMMARY F-Ioring No.HD83-24 Susitna Hydroelectric Project ----------,-'--~--""---_.....:...-_----- BORING NO.HD83-25 d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wz~tn SIEVE ANALYSIS (%)I LIMITS CONTENwUJIou..>o eo:-'-'::z::-wii;1J1 0..o..w 1-1-U:::lJ1 a COBBLE GRAVEL SAND SILT/CLAY eo:wI-l.l.P.l.p.1.Wc (%)~~o..o..W -«o I-IJ1««:>-WW Z -'_:>-W w IJ1 V)I-o~::lUI-::z::~I- ,bnr.U",~_,C;~NIp,.c;e:;.Q ~Q e:;~.h ----- .,RTlT .K ?1-?1=i ~W N/A 6R 5 ?7.3 4.2 --- -- 3 BULK 25-28 GP N/A 50.0 45.3 4.7 ----- 4 ~ULK 41-45 GW N/A 57.9 39.1 3.0 --- - - 5 BULK 45-48 SW N/A 34.0 62.8 3.2 -----' 6 6ULK 50-58 SW N/A 32.0 65.0 3.0 - --- - 7 aULK 61-63 -N/A -- --- - - - 8 ~lJLK 71-74 GW~N/A 67.9 26.7 5.4 -- - -- Remarks: .~J I 1 1 1 L 1 1 1 1 1 1 1 1 'I r.t.. 1 1 1 LAB TEST SUMMARY -loring No.HD83-25 Susitna Hydroelectric Project SUSITNA JOINT VENTURE 1 BORING NO. RD83 Q16 ~I~PARTICLE SIZE ANALYSIS REMARKSd~«W ATTER8ERG MOIST. ,z ':din ,LIMITS CONTEN 1 w w 0 .....>SIEVE ANALYSIS (%)OCll:~~I-win'"~~w 1-1-ii:"'ti COBBLE GRAVEL SAND SILT/CLAY Cll:wI-L.L.P.L.PI.Wc (%)~~~~w -<o I-'"«>WW Z ~_>w w '"'"I-0 .....::lUI-I ~l- I 1 13UiLK 10-13 -N/A - ----- - - 2 13UiLK 15-18 _.~-N/A 61.2 31.8 7.0 --- - -.....,"" 1 3 IBULK 20-23 -N/A - ------- 1 4 !BULK 25-28 GP~N/A 68.9 25.7 5.4 ----- 5 IBULK 30-33 GP~N/A 65.0 26.4 8.6 -- -- - 1 6 !BULK 35-38 -N/A - ---- - -- 7 ~ULK 40-43 SF-SIY N/A 27.0 65.8 7.2 --- - -1 8 !BULK 45-48 N/A --- - - --- - 1 9 !BULK 52-54 GM N/A 48.7 34.0 17.3 -- --- 10 !BtU 55-58 -N/A ---- - - -- 1 11 !BULK 61-63 sw-sr-N/A 34.7 58.0 7.1 - -- -- 1 12 Bl[1<:1:-N/A --------v....v,-, l..j I1:SUU IV'-/,j ~/A ,j'.::1./L.'::J.'::J JU.<r A L.:J .l.:;1 '0 IUS "L../'0 1 L 'I "~ L L L Remarks: L 'LAB TEST SUMMARY :-ioringNo.RD83-26 ~usitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. HD83-27 d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSc(wz':::!lii I LIMITS !cONTENTww0....:>-SIEVE ANALYSIS [%)000:...J ...J J:-wi/ien Q.o..w 1-1-u:en t5 COBBLE GRAVEL SAND SILT/CLAY 00:wI-L.L.P.L.p.1.Wr;[%l~~o..o..W -c(o I-en c(c(:>-WW 5d~:>-ww en U'l I-0.'::.J:~I- 1 BULK 10-13 GW N/A 77.3 19.6 3.1 - ---- 2 BtU 15-18 GP-Qi N/A 69.0 24.7 6.3 ---- - 3 BULK 20-23 -N/A -------- 4 BULl<28-30 -N/A -- ---- - - 5 BULK 31-35 GP-G N/A 70.6 24.3 5.1 - -- - - 6 BULK 35-38 -N/A - ----- - - 7 BULl<40-45 GP N/A 72.9 22.7 4.4 --- - - 8 BULK 45-48 GP N/A 58.1 38.0 3.9 - - - - - 9 BULI<50-52 GP N/A 73.2 22.9 3.9 - -- - - 10 BULl<55-58 -N/A - --- - - - - 11 BULl<60-64 GW-Q N/A 71.6 23.1 5.3 - - - -- 12 BULl<65-68 GP-Q N/A 66.5 24.4 9.1 -- - - - '" Remarks: 1 1 1 1 1 1 1 1 1 1 1 L L L L L L LAB TEST SUMMARY-loring No.HD83-27 Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. HD83-"S .. d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wZ~tn !cONTEN'w 0 ....>-SIEVE ANALYSIS (%)I LIMITSwOl:ll:-'-'::z::-wjiilll Q.Q.w .........U:::1Il~COBBLE GRAVEL S.AND SILT/CLAY l:ll:w ....L.L.P.L.PI.Wc (%)~~Q.Q.W -«o ....1Il ««>WW Z-,_>ww III III .....o~:=lu ....::z::~.... 1 ~ULK 10-13 GW N/A 73.3 23.6 3.1 --- - - 2 ~ULK 14-18 GP-GM N/A 68.7 23.9 7.4 -- - - - 3 l3ULK 20-24 GP-GM N/A 62.0 28.8 9.2 X NOI -PIc sti -Gs =2.75 4 ~ULK 25-28 GP-GM N/A 64.6 29.0 6.4 .-.-- -- 5 l3ULK 30-34 GW-GM N/A 64.7 29.4 5.9 -- -- - 6 aULK 34-35 SP-SM N/A 12.6 81.6 5.8 X ----Gs =2.78 7 BULK 41-45 -N/A --- -- - - - 8 BULK 46-48 SP N/A 25.1 71.5 3.4 -- - - - 9 BULK 52-55 -N/A -- -- - - -- 10 BULK 65-68 GP-G':N/A 65.3 25.7 9.0 - - - -- 1 Remarks: 11--------------------------------------__--1 LAB TEST SUMMARY noring No.HD83-28 Susitna Hydroelectric Project SUSITNA JOINT VENTURE I J BORING NO.HD83-29 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSo«wz~t; SIEVE ANALYSIS (%)I LIMITS 1C0NTENlJww0....>-00::-J -J :t:-win Vl ~~w 1-1-LL:Vl~COBBLE GRAVEL SA/I.ID SILT/CLAY 0::wI-L.L.Pl.p.1.Wc (%)~~~~w -0«o I-V') 0«0«>-WW Z -'_>-ww Vl Vl I-0 ....::::lUI-:t:~I- J 1 aULK 10-15 -N/A ------ - - i aULK 15-20 Gw-G:N/A 56.8 37.6 5.6 ----2 -j 3 !BULK 20-25 GW-G N/A 55.8 34.6 9.6 -- - - - '. J 4 IBULK 25-30 -N/A -- --- - - - 5 IBULK 30-33 GP-G N/A 49.1 41.0 9.9 -- - - - I 6 IBULK 35-40 -N/A -- - --- - -...... 1 7 BULK 43-48 GP N/A 50.3 45.5 4.2 -- - - - 8 IBULK 50-54 -N/A -- - - ---- J.9 BULK 55-58 SW N/A 43.0 53.7 3.3 ----- , 10 BULK 65-68 -N/A -- - -- - - -1 11 BULl<73-75 GW N/A 73.9 22.4 3.7 -- - - - ~ l " I I I- 1 1 1 1 Remarks: 0 ~ LAB TEST SUMMARY ;1oring No.HD83-29 Susitna Hydroelectric Project SUSITNA JOINT VENTURE !BORING NO. HD83-30 6 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSI«w I z ~tn SIEVE ....NALYSIS (%)I LIMITS iCONTEN W w cu.>Oll<:-'-'::I:-wVjon ~~tnQ..Q.w 1-1-u:::on~COBBLE GRAVEL SAND SILT/CLAY L.L.P.L.P.1.Wc (%)~~CL CL W -«««>WW Z -'_>w wononI-c~:=lUI-::I:~I- I 1 IBULK 10-15 -N/A -- - --- - - 2 BULK 15-20 GP N/A 56.4 39.2 4.4 ---- - 3 BULK 20-25 GW N/A 67.2 29.2 3.3 - - - -- I 4 BULK 27-30 -N/A - - --- - -- 5 lBULK 30-35 GW-G'N/A 61.3 32.1 6.6 - -- - - I 6 lBT.JLI<35-38 SW-9'N/A 24.3 68.4 7.3 --- - - 7 iBULK 40-45 -N/A -- - ----- 8 lBULK 45-48 SP N/A 43.8 52.9 3.3 - - - -- 9 BULK 55-58 -N/A - -- - --- - 10 BULK 60-65 GW N/A 63.6 33.4 3.0 - - - - - I I 1 I1""". I ..L Remarks: ! 1 ..... J J j 1 1 J J ·LAB TEST SUMMARY i>~oring No.HD83-30 $usitna Hydroelectric Project SUSITNA JOINT VENTURE ----'-----------------------------...., HD83-31 BORING NO. d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«Wzul-fcONTENT_II) SIEVE ANAlYSIS 1%)I LIMITSWlJ.1 0 ....>- 00.::-oJ -oJ I-wiijll) Q..0..W 1-1-U::II)o COBBLE SAND SILT/CLAY 0.::wI-l.l.?l.P.l.Wcl%}~~Q..Q..W -4::GRAVEL o I-II) ««>-W W z -oJ_>-wwII)U"l ....o~::lu ....I :::El- l BULK 1-2 GW-G'N/A 59.7 33.4 6.9 - -- - - 2 IBULK 5-8 -N/A ---- - - - - 3 BULK 10-13 GW N/A 67.9 28.9 3.2 - --- - 4 BULK 16-18 -N/A ---- - --- 5 BULK 21-24 -N/A -- - -- -- - 6 BULK 25-28 GW N/A 75.4 21.5 3.1 -- - -- 7 BULl<30-32 -N/A -- - - --- - 8 BULl<40-43 SP N/A 30.7 67.3 2.0 - -- - - 9 BULl<45-48 sw N/A 29.3 65.8 4.9 -- - - - 10 BULl<55-56 -N/A - ---- - - - 11 BULI<56-58 GW-Q NjA 59.4 33.6 7.0 -- - -- J j I~ J i :1 r- ! 1 J 1 J 1 J 1 1 L L L Remarks: 'I ~ LAB TEST SUMMARY -loring No.HD83-31 Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO. HD83-32 d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS4(wzul- I LIMITS IcONTENl_VI SIEVE ANALYSIS [%)w w 0 ....>-Oao:..........:r:-wiijVla..a..w 1-1-u:::VI 0 COBBLE GRAVEL SAND SILT/CLAY ~~li;L.t.P.L.P.1.Wc[%l~~a..a..W -4(4(4(>-Ww z .....>-Ww VI VI I-0 ....;:)U~:r:~l- I Bt.JLI<10-13 -N/A - - -- --- - 2 BULI<15-18 GW N/A 78.6 18.4 3.0 - ---- 3 BULK 20-23 GP-GJ.II N/A 61.0 30.3 8.7 ----- 4 BULK 25-26 GW N/A 51.8 43.4 4.8 - --- - 5 BlJIl<27-28 -N/A - - ----- - j ;, , , " Remarks: L J 1 I..... " 1 .1 1 1 'I..- 1 l l L L L L L SUSITNA JOINT VENTURE LAB TEST SUMMARY -'oring No.HD83-32 Susitna Hydroelectric Project---------------------- - BORING NO. HD83-33 d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wz~tn ANALYSIS (%),LIMITS IcONTENlwwOLL>SIEVE Oel:-'-'::I:-wj;j<ll Cl..Cl..w 1-1-U::::<II~COBBLE GRAVEL SAND SILT/CLAY eI:wI-L.L.P.L.PI.Wc(%l~~o..o..W -«o I-<II ««>-wW Z-'>-w w <II <II I-OLL ~ui=:I:~l- I I3ULK 10-15 GW N/A 68.3 28.2 3.5 - - ---, 2 BULK 15-20 -N/A -- ---- - - 3 BULK 20-23 GP-GM N/A 55.1 34.4 10.5 --- - - 1 t I , ]... i :. , I' >: L L L LRemarks: i· L ! - L J 1 1 1 I-. 1 J 1 L L 1 SUSITNA JOINT VENTURE LAB TEST SUMMARY -oring No..HD83-33 Susitna Hydroelectric Project---------------------------- BORING NO. HD83-34 ... 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSoo:(l:!:!Z ~1Il I LIMITS 1c0NTENlwwo~:>-SIEVE "'NAlYS~S (%)00<:-'-':z::-w<i)1Ila..o...w 1-1-LL<I)6 COBBLE GRAVEL S..v..ID SILT/CLAY IX wI-U.P.l.p.1.Wc (%)~~o...a..w -00:(o I-III 00:(00:(:>-Ww Z -'_:>-ww III III I-o~::lUI-:z::~l- I IBULK 6-7 -N/A -- ----- 2.BULK 10-13 GP~N/A 57.0 33.9 9.1 -- - - f L .L Remarks: 0 L ~ i L L I L j 1 1, 1 i ! 1 "' ,- 1 1 LAB TEST SUMMARY ~oring No.HD83-34 \:>usitna Hydroelectric Project SUSITNA JOINT VENTURE I BORING NO. HnR1-~' 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wZ~t; SIEVE ANALYStS (%)I LIMITS !cONTEN'w lJ,.1 ou..>-00<:-'-'I-wjj'i'"a..Q.w ~~i:i:"'~COBBLE GRAVEL SAND SILT/CLAY ~~t;1.L.P.L.p.1.We [%1:E ~.a..a..w -«««>Ww Z -'_>ww V'l V'l ~o~~U~I :E ~ 1 BULK 3-5 GW-GM N/A 67.4 27.1 5.5 ----- 2 3ULK 5-8 GW N/A 68.2 27.3 4.5 --- -- 3 3ULK 10-13 N/A ---- ----- 4 I3ULK 15-18 GW N/A 72.8 25.1 2.1 ----- 5 ~ULK 20-23 N/A - --- - -- -- 6 6ULK 25-28 -N/A - ---- - - - 7 SOLK 30-33 GW-GM N/A 50.7 43.7 5.6 ---- - 8 BULK 35-38 GW N/A 54.8.41.3 3.9 - - -- - I 9 BULK 40-43 -N/A - --- ---- 10 BULK 45-48 GP N/A 69.2 25.9 4.9 -- - -- t I 1 1 1 Remarks: i - 1 ~ 1 J J J 1 1 i J 1 LAB TEST SUMMARY noring No.HD83-35 ~usitna Hydroelectric Project SUSITNA JOINT VENTURE ..., BORlNG NO. m_R~."f, J 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS oC(WzI:::!l:ii (%)I LIMITS CONTEN W W 0 ....>-SIEVE ANALYSIS 00.:......-,:r:-wVi~~~w ....~U:::<I'l~COBBLE GRAVEL SAt>lD SILT/CLAY ex w ....L.L.P.L.P.1.Wc[%l~~"-,,-W -oC(o ....<Il oC(«>-w W z ......>-w wI<I'l <I'l ....o~::>ui=J:~"", J 1 SULK 5-8 GW~N/A 63.4 31.5 5.1 ---- - 2 BULK 10-13 GP-G-:N/A 59.7 28.8 11.5 -- --- J 3 IBULK 15-18 -N/A ------ -- ~4 ~20-22 -N/A ----- - - --, [11 ~, r ,11 ..... i J rf ~ 1i f:- ,I' ...... , 1 I.... T,- 1 Remarks: 1 .LAB TEST SUMMARY r;;oring No.HD83-36 ·dusitna Hydroelectric Project SUS/TNA JO/NT VENTURE BORING NO. RD83 37 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS4(w Z ~l:n SIEVE ANAlYSIS (%)I LIMITS icONTENl w w 0 ....>001:......--'::I:-Wii'jlll a.::wI-Q.Q. w 1-1-U:::1Il~COBBLE GRAVEL SAND SilT/CLAY l.l.P.l.PI.Wc (%)~~Q.Q.w -4(o I-tI') 4(4(>WW Z --'_>ww tI')III I-o~::)UI-:r:~1- I.1 U3UI.J<1-5 GW N/A 70.4 25.9 3.7 ---- - 2 BUI.J<5-8 -N/A ----- - - - 3 BUI.J<10-13 GP-G'N/A 63.9 30.6 5.5 - -- -- 4 BUI.J<15-18 -N/A ----- --- 5 BUI.J<20-25 GW N/A 73.7 23.5 2.8 - -- - - 6 BULK 25-26 GW N/A 75.3 22.9 1.8 -- - - - I 7 BULl<30-35 -N/A -- - - -- - - 8 1BULl<35-40 -N/A --- - --- - 9 BUIJ<40-45 GW N/A 74.2 22.2 3.6 - - --- 10 Bt..JLI<45-50 GW N/A 81.8 14.4 3.8 --- -- 11 BUL~50-55 -N/A - -- - -- - - 12 BUI.J<55-60 -N/A - - - - -- - - 13 BUI.J<60-65 GW N/A 81.7 15.4 2.9 -- - - - I BUU 65-70 GP..-Gl N/A 72.2 20.6 7.2 - - - --14 I 15 BtJIi 70-75 -N/A - - -- - - - - 16 1BtJLl<75-80 GP-Q N/A 75.6 19.2 5.2 - - - -- 1 17 BUI.J<85-88 -N/A - ---- - -- 18 BUU 88-94 GW N/A 77.6 20.1 2.3 - - - - - 19 IBUll 96-10 b-N/A - - - - - - -- 1 20 BUIJ lIOO-I0 [:)GP N/A 55.2 41.6 3.2 - - - -- ! 1 Remarks: ! 1 .... f·... 1 J J 1 1 1 1 1 J LAB TEST SUMMARY ;loring No.RD83-37 Susitna Hydroelectric Project SUS/TNA JO/NT VENTURE ~ 1 BORING NO.HD83-37 0 ~J~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«WZu~ I LIMITS !cONTEN'-'"SIEVE ANALYSIS (%)W U..I 0"->000:1 --'--'::I:-win'"~~t;:;A.A.w ~~U:"':5 COBBLE GRAVEL SAND SILT/CLAY L.l.PL.PI.Wc(%l~~A.Q..w -« ««>WW Z--'_>w w '"'"~o~:::lU~::I:~~ J 21 ~T1T.K 11-11.1 GW N/A 68.6 27.5 3.9 --- --I 22 RTlT.K 18-12 N/A --------- I I:lTlT.K 25-13(N/A -- --I23-- --- 1~ 24 Ior1Tu 31-13 GP-GC N/A 68.2 21.7 10.1 -- - -- t iRm .K 36-14(GW-GrI.N/A 76.0 18.2 5.8 - ----25 - 1 26 l3lJLK 40-14 -N/A ------- - , 1 ~ 1 Of-I 1 I,... 1 f...... L Remarks: 1 ': I 1r- I ...AS TEST SUMMARY ~oring No.HD83-37 '..;usitna Hydroelectric Project SUSITNA JOINT VENTURE HD83-38 ,i d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wZv~LIMITS CONTENl_V)SIEVE ANAlYSIS [%)Iww0....>-00::..........:x::-!:!;!ii'i Vl CL.CL.w ~~....lIltj COBBLE GRAVEL SAND SILT/CLAY ~~ln L.L.P.L.p.1.We [%1~~CL.CL.w -«««>-Ww z .....>-Ww V)Vl ~o~:::>V~J:~~ 1 I3ULK 3-6 GP-GM N/A 57.6 33.5 8.9 --- -- 2 I3ULK 7-10 -N/A ----- --- 3 I3ULK 13-15 GW N/A 57.6 37.7 4.7 -- -- - 4 BULK 17-20 -N/A - ----- - - 5 BULK 23-25 GW N/A 75.0 22.4 2.6 --- -- 6 aULK 25-27 -N/A -- - - - -- - 7 BULK 30-33 GP-GM N/A 57.8 32.8 9.4 --- -- 8 ~ULK 35-38 -N/A ------ - - 9 BULK 40-43 8M N/A 42.3 43.3 14.2 ---- - 10 BULK 45-48 -N/A --- -- --- 11 ~ULK 50-53 GM N/A 41.3 40.1 18.6 ----- 12 aULK 55-58 -N/A --- ---- - 13 iBULK 60-63 GP-G':NjA 59.9 30.8 9.3 ---- - 14 BULK 65-68 -N/A - -- -- - -- 15 iBULK 70-73 GP-G'N/A 70.0 23.0 7.0 -- - -- 16 !BULK 75-78 -N/A --- --- -- 17 BULK 80-83 GW N/A 77.1 18.0 4.9 ---- - 18 BULK 85-88 -N/A ----- - - - 19 BULl<90-93 GW-Gr'N/A 54.5 39.1 6.4 -- - -- BORING NO. I""'" I 1 ,1 Remarks: 1--------------------------------------' J J J j Ir- j Ii~ 1 1 LAB TEST SUMMARY rioring No.HD83-38 .dusitna Hydroelectric Project SUSITNA JOINT VENTURE HD83·-39 Remarks: 0 ~I:E PARTICLE SIZE ANALYSIS AHERBERG MOIST.REMARKS<{wz~li;I LIMITS CONTENl W W 0 ....>SIEVE ANALYSIS {%}00::...J ...J r-wiiill)a..a..·w ~~U::II)O COBBLE GRAVEL SAND SILT/CLAY 0::w~L.l.P.L.PI.Wc (%}:E :Ea..a,.W -<{o ~V'l <{<{>wW SCi=:>lJ.I w V'l II)~0 ....r :E~ 1 BULK 5-8 GW-G-N/A 58.2 35.1 6.7 -----GJ=:=2.74 2 BULK 10-15 -N/A -- - ----- 3 BULK 15-20 GP-G N/A 60.7 32.5 6.8 - - - - - Gs =2.80 4 BULK 20-25 -N/A - - -.----- 5 BULK 25-34 GP-G N/A 50.7 42.1 7.2 - ---- 6 IBULK 35-40 -N/A - ---- - - - 7 BULK 40-48 GW N/A 59.5 36.6 3.9 - -- -- 8 BULK 50-55 -N/A - - - - - --_. 9 BULK 55-60 GW.....Q N/A 72.4 21.2 6.4 ----- 10 BULl<60-65 -N/A -- ----- - 11 BULK 65-70 GP~-N/A 65.8 26.5 7.7 - --- -Gs =2.82 12 BULl<70-74 -N/A -------- 13 BULK 75-78 SM N/A 40.2 43.3 16.5 ----- 14 BULB 80-85 -N/A -------- It::.IPTTr.l<:Qt::..•QQ ,c:::P_1C:l\MIn..1.n 7 S3,1 h ,?- ----I~..,,?7F.. 16 BULK 90-95 -N/A -- -- - --- 17 BULK 100-10 GP-G N/A 54.3 37.0 8.7 -----Gs =2.76 18 BULK 105-10 ~-N/A --- - -- -- 19 BULK 108-11 BGW-G N/A 61.4 33.4 5.2 - -- - - 20 BULK ll.l5-11 S GP~N/A 52.4 37.8 10.1 - - - - - BORING NO. J J ! j j , J J J J J 1 1 J ,1, I J I,- -------------......;..-----------------, 1 LAB TEST SUMMARY..... I 30ring No.HD83-39 Susitna Hydroelectric Project SUS/TNA JOINT VENTURE BORING NO. HD83-39 (j ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~wZI::!ti SIEVE ANAlYSIS (%1 I LIMITS kONTEN w w ou..>-001:-'-'J:-w;nVl 01:wI-a..a..w 1-1-U:::Vl~COBBLE GRAVEL SAI'IID SILT/CLAY L.L.p.L.p.l.Wc (%)~~a..a..W -~o I-en>-Ww~<>-WW Z -'_J::::E l-on en I-o~::JU .... 21 brrr .K 20-12 N/A - -------- 22 brrr .K 23-12 Gw--Gl'<N/A 68.9 25.6 5.5 -----I BULK N/A -----23 30-13 --- - 24 BULK 35-13 SP-~N/A 56.3 34.0 9.7 .-----Gs =2.77 25 BUI...K 40-14 N/A --- ------ r 26 BUI.J<tl.45-14 B GW-G N/A 68.4 26.3 5.3 -----, t l 1 i Remarks: i -I 1 1 1 1 J 1 1, J 1 1 LAB TEST SUMMARY noring No.HD83-39 dusitna Hydroelectric Project SUS/TNA JOINT VENTURE BORING NO. HD83 40 d ~~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS ..{LLI Z ~tri SIEVE ANAlYSIS (%)I LIMITS CONTENWW0"->-OlX..........J:-wii'jVl Q..Q.. w 1-1-u::V')~COBBLE GRAVEL SAND SILT/CLAY lXWI-u.P.L.p.1.Wc (%)~~Q..Q..w -oc(o I-V') 0«<>-w W Z ....._>-W wV')V')I-o~::lUI-J::!:I- 1 1BULl<4-8 -N/A ------ - - 2 1BULl<10-15 Gw-G'N/A 52.6 38.9 8.5 ---- - 3 BULl<15-20 -N/A - - ----- - 4 BULl<20-25 -N/A --- - ---- 5 BlJLF 25-30 GW N/A 59.7 36.1 4.2 ---- - Gs =2.76 6 BULl<30-35 Gw-G'N/A 69.3 24.4 6.3 --- -- I I I Remarks: ....J 1 1 , 1 1 1 J J j J j 1 l 1 i 'LAB TEST SUMMARY r""Joring No.HD83-40 $usitna Hydroelectric Project SUS/TNA JOINT VENTURE HD83-41 (j I I I~I~PARTICLE SIZE ANALYSIS REMARKS«w ATTERBERG MOIST. Z ~t;I LIMITS ~ONTENTww0....>-SIEVE ANAlYSIS (%)Oc<:~~:I:-w in 1110...Q.w ~~~~~COBBLE GRAVEL SAND SILT/CLAY c<:w~L.L.p.L.p.1.Wc(%l~~Q.Q.w o ~111 ««>-Ww 5di=>-ww 111 111 ~o~:I:~~ 1 BULK 5-10 8M NjA 34.2 48.8 17.0 --- -- 2 BULK 10-15 -NjA - ----- -- 3 BULK 15-20 GP-GM NjA 55.1 35.9 9.0 -----Gs =2.76 4 BULK 20-25 -NjA ---.--- -- 5 BULK 25-30 8P-Sl-Io NjA 32.6 57.5 9.9 - ---- 6 BULK 30-35 GP-G!o NjA 47.0 43.7 9.3 -----Gs =2.76 7 BULK 35-40 -NjA - --- - - - - 8 BULK 40-45 -NjA -- -- - --- 9 BULK 45-50 8M NjA 32.5 51.3 16.2 ---- - Gs =2.78 10 BULK 50-55 -NjA ------ - - 11 BULK 55-60 GP-Qi NjA 54.7 39.4 5.9 -- - - - 12 BULK 60-65 GP-Qi NjA 47.6 45.6 6.8 -- -- - 13 Bt.JLI<65-70 SW-~NjA 40.1 48.1 11.8 ---- - 14 BT.JLI<70-75 GM NjA 45.7 38.8 15.5 -----Gs =2.68 15 BUlJ'i 75-80 -NjA --- --- - - 16 BULlI 80-83 -NjA - - - - -- - - 1 1 ]BORING NO. I I i J J j J J I 1 ) , 1 1 , 1 1 1 1 Remarks: f 1,---------------------------------------' 'LAB TEST SUMMARY lloring No.HD83-41 dusitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO.HD83-1..Z ~~~~._~ 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST_REMARKS·oe(w Z u~LIMITS iCONTENT_VI SIEVE ANALYSIS (%)IwwOu...>00.:-'-':1:-wiijU'l 0-o..w ~~L:LU'ltj COBBLE GRAVEL SAND SILT/CLAY ao:LU~L.l.P.L.PL Wc (%)~~o..o..W -oe(o ~Vl oe(oe(>LU W Z -'_>LU W VI VI ~o~:::lU~::c :E ~ 1 IBULK 12-17 N/A - - ------ 2 ~ULK 20-23 SF N/A 32.1 63.2 4.7 -- ---Gs =2.76 3 1BULl<25-28 GW N/A 64.2 32.0 3.8 ---- - 4 IBULK 30-33 GP-G N/A 64.0 29.1 6.9 --- - -. 5 BULK 35-38 SW N/A 46.7 48.9 4.4 --- - - 6 1BULI<40-43 -N/A --- --- - - 7 BULI<45-48 8M N/A 19.1 66.9 13.2 - - -- - 8 BULI<50-55 -N/A - --- ---- 9 BtJLI<55-60 SP N/A 47.6 44.1 3.3 - - - --G5 =2.75 10 BT.JLI<60-65 G"W-G N/A 61.6 32.6 5.8 ---- - 11 BtJLI<65-68 SC N/A 31.5 32.9 35.6 -26 18 8 - Remarks: 1 1 J 1 1 1 1 1 L l L L L L L L L LAB TEST SUMMARY ""oring No.HD83-42 '=iusitna Hydroelectric Project SUS/TNA JO/NT VENTURE I BORING NO.HD83-43 ...., 0 ~I~PARriCLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wZul- I LIMITS CONTENl_VI SIEVE ANAlYSIS (%)J LLJ W o u..>.O~..........:I:-win VlQ.Q.w 1-1-~"'~COBBLE GRAVEL SAND SILT/CLAY ~~tii L.l.p.L.p.1.Wc (%)~:lEa..Q.w -«««>Ww Z ....._>ww Vl Vl I-o~::lUI-J:~I- 1 BULK 10-15 SF N/A 46.3 50.2 3.5 --- - -1 2 IBULK 15-20 GP N/A 50.1 46.8 3.1 --- - - 1 3 IBULI<20-25 N/A --------- 1 4 1BULl<25-30 mv N/A 50.6 46.9 2.5 ----- BULl<GW-G N/A 56.9 35.4 7.7 ----5 30-35 - 1 6 BULl<35-40 SP N/A 37.6 58.6 3.8 -----Proctor D698 m::oy:-:lai "lnC'f BULl<40-45 GW-G'N/A 70.6 24.4 5.0 -----wopt=6.0% 1 7 G =2.83.,- BULl<N/A ----8 45-50 ----- I 9 IBULF 50-55 SM-SC N/A 39.7 41.4 18.9 -22 18 14 - ~ 10 BULl'55-58 -N/A ------- - I 11 BUU 60-63 GM N/A 56.5 25.5 18.0 -----~ 1 12 BUU 65-67 SW N/A 41.1 56.8 2.1 ---- - I..... 1 1 1 1 1 Remarks: L 'LAB TEST SUMMARY 40ring No.HD83-43 dusitna Hydroelectric Project SUS/TNA JOINT VENTURE ....,'------------------------------, 6 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wz~li;I LIMITS !cONTENTwwou..>SIEVE ANALYSIS (%l o eo:-'-':c-winV'a..a..w ........U::V'~COBBLE GRAVEL SA/'IID SILT/CLAY eo:w ....L.L.P.l.p.1.Wc(%l~~a..a..w -«o ....Vl ««>WW Z-'>w w Vl Vl ....o~::::I U i=.:c::E .... 1 SULK 10-15 SW N/A 44.6 52.7 2.7 ----- 2 ~ULK 15-18 SP N/A 34.7 60.8 4.5 ----- 3 ~ULK 18-25 -N/A -- ------ 4 ~ULK 25-30 SP N/A 47.4 50.7 1.9 ----- 5 ~ULK 30-35 GW N/A 64.4 31.7 3.9 --- - - 6 ~ULK 35-40 -N/A --- ---- - Proctor 698 n-o.,v:-:1~<:;""'('i- 7 ~ULK 40-45 SP N/A 33.5 63.6 2.9 wopt.=10.0-----G =2.81 ::; 8 ~ULK 45-50 SW-SC N/A 39.9 51.4 8.7 -25 20 5 - 9 IBULK 50-55 GW~N/A 51.0 43.4 5.6 ----- 10 !BULK 55-60 -N/A - -- -- --- 11 BULK 60-65 GW-Q N/A 53.4 39.5 7.1 - -- - - 1 1 ~, ! ~ 1 1 1 1 BORING NO. HD83-44 1 1 ~ 1 1 1 1 1 Remarks: 1 LAB TEST SUMMARY :soring No.HD83-44 Susitna Hydroelectric Project SUSITNA JOINT VENTURE 1 BORING NO.HD83-A5 (j ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«w 1 z ~t;;SIEVE ANALYSIS (%)1 LIMITS rCONTEN'w w 0 ....>-00.:..........:1:-w<;;V) ~w ...Q.Q.w ......u:::V)~COBBLE GRAVEL SA/Io,ID SILT/CLAY L.L.PL.P.1.Wc (%)~~Q.Q.LU -«o ...v) ««>-LU W Z ....._>-LU wV)V)...o~::lU ...r::E ... 1 1 SULK 0-4 -N/A - --- - - -- 2 SULK 4-7 Gw-GM N/A 60.2 32.0 7.8 X - - - - 1 3 J3ULK 10-13 N/A - - -- - --- 1 4 aULK 14-17 Gw-Gl N/A 62.9 31.2 5.9 - ---- 5 IBULK 20-23 -N/A - -- - --- - 1 6 ~ULK 24-27 GM N/A 47.8 40.1 12.4 X Nol -PI,sti t-- 1 7 IBULK 30-33 -N/A ---- - - - - SW-~8 IBULK 35-38 N/A 39.2 51.5 9.3 X --- - ~9 SULK 40-43 -N/A - - --- - -- !10 BULK 45-47 GP-GM N/A 45.2 46.4 8.4 - - -- - l 11 BULK 50-53 -N/A --- --- - - 1 1 1 i 1 1 1 1 Remarks: I : 1 L.AB TEST SUMMARY ~oring No.HD93-45 I •dusitna Hydroelectric Project SUSITNA JOINT VENTURE -~-------------------------.., (j ~'~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«11.1z~t;;I LIMITS CONTENlwwou..:>-SIEVE ANALYSIS (%)00'-'-'~-wij'iVl Q..Q..w 1-1-ii:Vl t5 COBBLE GRAVEL SAND SILT/CLAY 0'wI-L.l.P.L.p.1.Wr;[%l~~Q..Q.w -«Ol-Vl oct:«>-11.111.1 5ui=>-Ww Vl Vl I-o~~~I- 1 RTTT J<?-J:;-N/A - - --- - ?BTJT .I<5-10 Gw-G-N/A 54.3 33.1 10.6 --- -- 3 BUI..R 10-13 -N/A -------- Organic content= 4 BUI..R 13-16 CH N/A 24.7 18.0 57.3 -56 52 4 -13.9% Organ1c content 5 1BUI..R 17-20 8M N/A 5.9 47.5 46.6 -No ~-Pl !lsti ro -2.8% 6 BUI..E<20-25 -N/A -------- 7 BUU 25-29 GP-c;r N/A 48.2 42.4 9.4 -- - -- 8 Bt1.LI'30-34 -N/A - ------- 9 BUU 34-39 GP-Gl N/A 46.8 43.7 9.5 ----- 10 BULl<40-45 SP N/A 32.3 63.5 4.2 ----- 11 BUU 45-48 -N/A -- - ---- - I 'i.·BORING NO.HD83-46 I 1 1 ~1 Remarks: 1.--------------------------------------...... LAB TEST SUMMARY "1oring No.HD83-46 dusitna Hydroelectric Project SUSITNA JOINT VENTURE 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSo(w:Z vI-LIMITS CONTEN_V) SIEVE ANAlYSIS (%)Iww0....>-Oao:............r-wiiiV)a..a..w ~I-":V)~COBBLE SILT/CLAY ao:wI-U.P.l.p.1.We (%1~~a..a..W -0(GRAVEL SA/I.ID o ~V) 0(0(>-WW ~u+=>-Ww Vi V)+-o~r ::E l- I ~ULK 2-4 GP-GM N/A 63.3 30.5 6.2 ---- - 2 BULK 4-8 SM N/A 35.5 45.8 18.7 -N01 -PIc sti - 3 IBULK 10-14 -N/A - --- --- - 4 IBULK 20-23 GW-GM N/A 56.7 36.0 7.3 - - -- - 5 IBULK 24-28 SP N/A 37.7 59.0 3.3 ---- - 6 IBULK 30-33 -N/A - ---- --- 7 IBULK 34-38 GW N/A 50.6 44.8 4.6 --- -- 8 IBULK 40-41 SP-~N/A 14.1 77.7 8.2 -- - - - 9 IBULK 41-45 -N/A -- -- ---- 10 IBULK 45-48 -N/A ------ -- 11 IBULK 60-64 GW-QJ N/A 47.1 43.0 9.9 -18 15 3 - 12 IBULK 64-65 -N/A - - -- - - - - , J BORING NO.HD83-47 f-- L Remarks: I'F .......l LAB TEST SUMMARY r-loring No.HD83-47 dusitna Hydroelectric Project SUS/TNA JO/NT VENTURE 0 ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSo«wzu.....LIMITS !CONTENT_<I) SIEVE ANAlYSIS ("/,,)IWW0.....> 00.:............I-wjj;<I)~a............U:::<I)~0.:w .....=E =E~a..W -0«COBBLE GRAVEL SAND SILT/CLAY 0 .....<1)L.L.P.L.p.1.Wc [%) 0««>W W z ......>Ww <I)lI'l .....o~::::lU~I~..... 1 BULK 10-15 -N/A ------- - 2 BULK 15-19 sp N/A 14.9 80.7 4.4 -- - -- 3 BULl<19-25 -N/A - --- - --- 4 1BULl<25-30 sp-go N/A 42.5 48.9 8.6 .-No Il-Pl sti C!- 5 BULK 30-35 -N/A ---- - - -- 6 BULF 35-40 GW N/A 67.2 31.2 1.6 - ---- 7 BtJLI<42-47 GW N/A 53.2 43.9 2.7 ---- - 8 BtJLI<50-55 -N/A -- - ----- 9 BT..JI.J<55-58 SP N/A 20.7 76.1 3.2 -No I1-P1 Ilsti t::- 10 BULl'.60-65 -N/A -- - --- - - 11 IBUU 65-69 GW-G N/A 32.9 60.9 6.2 ----- 12 loou 70-75 GP-G N/A 51.2 38.0 10.8 ----- 13 BUU 75-78 -N/A -- --- -- - 14 BUll 80-85 GC N/A 49.7 33.7 16.6 X 27 18 9 - 15 B{,JI.J 85-88 GP-G1 N/A 57.2 33.8 9.0 ----- II BORING NO.HD83-48 ~ J J J j I ,II r- li..- flr- 1 ~-. 11 "'"" Remarks: 1 f..., !'-----------------------' L.AB TEST SUMMARY ...qoring No.-HD83-48 Jusitna Hydroelectric Project SUSITNA JOINT VENTURE HD83-1 (}.....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~-e{wZ~li;LIMITS CONTENlSIEVEANAlYSIS(%)IwI.L'ou..>-Ocx....._.I-win<nC-a..w ~~Li:<Il3 SILT/CLAY ~~li;Wc (%)~~a..a..W --e{COBBLE GRAVEL SAND L.L.P.L.p.1. -e{-e{>-WW z .....>-ww <n VI ~o~::>V~I~.... 1 BtJLK 2-9 SM N/A 33.4 48.3 18.3 - -- - - 2 8PT 9-10 -- ---- - - - 8.9 3 BtJLK 19-20 SM N/A 20.2 49.1 30.7 X -- -- BULK 26-28 N/A 40.0 30.2 '.. 4 8M 29.8 ---- - 5 S1?T 28-29 ---- - ----- 6 BIJLK 32-34 SM-SC N/A 21.1 39.5 39.4 X 18 13 5 - 7 BtJLK 37-38 -- - - - -- --- ~!:::>PT j~-jY ----- -- --- 9 BtJLK 44-45 ---- - --- -- 10 BIJLK 50-52 8M N/A 11.3 42.7 46.0 X No iJ.-Pl ~stl p- 11 BULK 55-56 SM N/A 17.8 41.4 40.8 ----- 12 BIJLK 60-62 SM N/A 27.0 32.9 40.1 ----- 13 BIJLK 65-66 SC N/A 25.8 37.8 36.4 -24 14 10 - 13B 8PT 69-71 SC -- -- - 42 18 24 12.4 14 BUil 71-72 SM N/A 19.7 35.1 45.2 X ---- 15 BUil 75-76 SM N/A 22.6 41.1 36.3 -- -- - 16 Bl.JI1i 77 ---- ------ 17 BULl<80-81 SM N/A 30.2 39.7 30.1 ---- - 18 BT.JLB 85-88 SM N/A 21.3 42.3 36.4 -Nc ~-Pl asti t:- 18B 8PT 89-90 -- ---- - - - 11.3 Remarks: 1 t""'" 1 I...... 1 t- BORING NO.J J J J , 1 1 Ii ~ 1.---...,;,----1 L.AB TEST SUMMARY ".E:Joring No.HD83-1 Jusitna Hydroelectric Project SUSITNA JOINT VENTURE HD83-1 0 ..JI::E PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~o{wzul-LIMITS !CONTENT_VI SIEVE ANAlYSIS(%)Iw·W 01.1..>-00<:-,.-':1:-wiijo.l'la..a..w 1-1-U::o.I'I b SILT/CLAY a<:wI-l.l.P.L.PI.We (%)::E ::Ea..a..W -0{COBBLE GRAVEL S.Afl"JO 01-0.1'1 -<o{>-WW Z ..J_>-w w0.1'1 VI I-o~=:JUI-r ::E l- i Ii 19 lBuLK 90-92 SM N/A 20.5 44.7 34.8 - - - - 1- 20 BULK 95-96 8M N/A 37.4 43.0 19.6 ----- 21 'RT1ff .K 00-10 8M N/A 30.4 40.5 29.4 ----- 22 BULK 07-lm 8M N/A 19.8 47.3 32.9 X No ~-Pl ~sti h- 23 IRT11T J(14-1lE 8M N/A 27.3 43.4 29.3 ---- - 24 IRTlT .T(21-12,8M N/A 29.9 41.2 28.9 -17 15 2 4.4 25 I'RT1ff.r<26-12i 8M N/A 21.6 48.9 29.5 _.17 15 2 2.6 26 IHm .T(31-13 SM-S ~N/A 9.2 54.3 36.5 -19 14 5 5.3 27 BULK 36-13~SM+S ~N/A 12.0 50.9 37.1 -20 14 8 5.8 28 BULK 41-14 SM N/A 17.8 56.7 26.1 X 18 16 2 2.7 29 ImlT.K 46-14~8M N/A 21.5 51.4 27.1 -Non PIa ;;tic 4.7 30 ~RTlT J<51-15 ---------- 31 RTlT .r<61-16 8M N/A 35.3 41.6 23.1 -Non PIa ;;tic 2.9 32 IRTlT.K 66-16~- --------3.1 33 IRTlT .r<74-17f --- - -- - --1.3 .34 BULK 78-18C 8M N/A 13.6 74.4 12.0 -0.6,-- - i 35 I'RT ,IT .r<83-18'8M N/A 38.1 49.8 12.1 -Non PIa ;;tic 2.2f ! i 36 BULK 88-19C 8M N/A 43.4 44.0 12.6 - ---2.7! ,37 Imrr .r<94-19(8M N/A 10.8 64.0 25.2 X.Non ..PIa ;tic -I i 38 BULK ~00...20.8M N/A 20.1 52.1 27.8 -18 16 2 12.6 I BORING NO. Remarks: II,.- ~ l L L ~- ~f""'. l -------------------------------------------' "1 1~ II,.... J1 J 1 LAB TEST SUMMARY ~oring No.HD83-1 ~usitna Hydroelectric Project SUS/TNA JO/NT VENTUflE J , IJ J J I I' J 1 J I' J j j i l " !""" \ ~ ! J 1 , 1 ~ J ) BORING NO.HD83-1 d ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~c(wZ~ti;LIMITS CONTEN'w U-I Qu...>SIEVE ANALYSIS (%)I...._.r-wiijen o a.: CL.~w ~~~en~~~til~•CL.CL.W -c(COBBLE GRAVEL SAND SILT/CLAY L.L.P.L.PI.Wc (%) c(c(>w W 5d~>ww en III ~a!:;.r~~ 39 1=l.TlT J(D08-21 SW-~N/A 21.3 69.2 9.5 --- -- 40 BULK ~25-23 8M N/A 15.4 63.7 20.9 ...:NOn PIa tic - 41 BULK 243-24 )SM-sd N/A 22.0 38.9 39.1 X 20 16 4 - 42 BULl<255-25 'CL N/A 11.7 21.8 61.0 .-26 18 8 13.2 Organic Content 2.1% 43 BULl<260-26 SC N/A 22.4 37.8 39.8 -31 17 14 8.5 Organic Content 1.4% 44 BULl<~63-26 8M N/A 18.5 32.4 49.1 ----18.0 45 BUI..F ~70-27 CL N/A 0.7 6.1 93.2 ----22.7 46 BULl<~76-27 3 CL-MI N/A -0-1.6 98.4 X 25 20 5 21.4 47 BUI..F ~82-28 i CL N/A -0-5.3 94.7 -31 22 9 24.0 48 BULl<~90-29 CL N/A -0-2.5 97.5 -29 22 7 22.0 49 BUI..F 295-29 5GM N/A 35.2 34.6 30.2 - - - -- 50 BULl<299-30 )GM N/A 34.2 28.2 37.6 X --- - 51 BtJLI<304-30 5 ------ - --- 52 PI[IT.J<~05-30 :>Gw-Q N/A 66.6 26.7 6.7 - -- -- 53 BOU 308-30 ;l GP-Gl N/A 72.5 19.7 7.8 - ---- 54 BUU ~09-31P GP-Gl N/A 51.1 37.4 11.5 X Non ~Pla stic- 55 BOU ~12-31 S GP N/A 64.8 33.0 2.2 - --- - 56 BUIJ [314-31 pGW N/A 58.0 39.9 2.1 - - -- - 57 BUIJ ;316-31 rJ SW N/A 37.8 59.1 3.1 -- -- - 58 BULE 321-32 2 GP £VA b.1.U ..:54.::>4.::>- -- - Remarks: 0 LAB TEST SUMMARY ~oring No.HD83-1 dusitna Hydroelectric Project SUSITNA JOINT VENTURE ....,--------------------------------------., 0 -112:PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~<I(wZ':,dtn I LIMITS kONTENl w lJ,J 0 .....>-SIEVE ANALYSIS (%)Ocr:-I -I I-wijiV)a.a.w ........U:::V)~COBBLE SilT/CLAY 2:5 ~tn L.L.P.L.PI.Wc (%)~~a.a.w -<I(GRAVEL SAND <I(<1(>-Ww ~di=>-ww V)V)....o~I~"" 1 BuLK 3-8 sr-1 12.2 27.1 47.5 13.2 --- - - 2 SPT 8-10 8M 0.0 26.0 55.1 18.9 - ---12.5 3 BULl<13-14 GM 9.7 44.4 31.3 13.1 -20 17 3 8.1 4 BUI.J<14-17 GP-<~8.8 57.8 24.4 9.0 - ---17.7 5 SFT ------- --- - 6 BlJLI<18-2D GM 0.0 51.0 36.9 12.1 --- - 12.7 7 SPT 20-21 -- ----- --16.6 8 BULl<24-25 8M 0.0 2.8 74.5 22.7 -No Il-Pl sti P 10.8 9 SPT 28-29 - -- ----- - 12.1 10 BtJLI<33-34 8M 0.0 4.8 79.2 16.0 - - - - 8.2 11 BllLl<36-37 SW-~lM 0.0 12.7 76.5 10.8 -- --6.1 12 SPT 38-39 ---- -- - - - 5.9 13 BI.JI..J<40-41 SC 0.0 2.1 64.9 33.0 -34 23 11 19.2 14 BIJI.,I<44-45 8M 0.0 0.9 85.7 13.4 - - - -- 15 BlJU 46-47 8M 0.0 15.1 70.1 14.8 ----6.4 16 BUll 49-50 SW-~lM 0.0 16.1 72.9 11.0 - -- - 5.2 17 BULF 52-53 8M 0.0 5.5 82.0 12.5 -Nc h-Pl astip - 18 BUU 55-56 SW-~~0.0 3.5 84.9 11.6 -Nc p-P1 astib 6.1 19 SFT 58-59 --- ---- - - - 20 BUlJ 61-62 SW-1 ~0.0 29.1 59.8 11.1 ---- - 1 I.... 1 Remarks:1 1 ---1 I BORING NO.HD83-2 "... j 1 l f.... 1 i " 1 Ii'"' ! 'LAB TEST SUMMARY rJoring No.HD83-2 dusitna Hydroelectric Project SUSITNA JOINT VENTURE SUS/TNA JOINT VENTURE BORI~lG NO.HD83-2 , d .....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«wzul-LIMITS jcONTEN1_VI SIEVE ANAlYSIS (%)Iw~0"'>-o ell:.....-,I-win Vl 0-O-w 1-1-LLVl3 COBBLE GRAVEL SAND SILT/CLAY CI:wI-LL.p.L.PI.Wc (%)~~O-O-W -«o I-VI««>-W W Z ....._>-ww VI <n I-0'"~Ul-J:~I- '11 lorrr Ie t::.t::._t::.7 ~f'\f'\~')Q~a 1')a -l\Tt'"'I _01 .C!t-;...-:t,? ')')PJ'lT.1<71_7?~-~M f'\?Q n &=;1 Q 1 n .1 - - -h.() 23 BlJI.1<76-77 - ----- ---- , I I I Remarks: I I I""" i r" \LAB TEST SUMMARY rCloring No.HD83-2 ;Jusitna Hydroelectric Project r-' I -. J Ir J 1 ; I~ - J J j J 1 J J j ) J 1 1 ~ i f ~ ! J ! I 1 ! BORINIG NO.HD83-3 0 .....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~<{Wz'.::dti LIMITS kONTEN'w OLL.>-SIEVE ANALYSIS (%), w Oc<:..........:I:-~UiU'll;L l;LW ~~LL.U'l~COBBLE GRAVEL SAND SILT/CLAY c<:w~L.L.Pl.P.1.Wc{%l~~l;L l;LW -<{o ~U'l <{<{>-WW z .....>-W w U'l U'l ~o~::::lui=::I:~~ 1 1Bt.JLI<7-9 ---------- 2 IBULl<14-15 SM-SC 0.0 13.0 41.7 45.3 X 2 14 6 15.4 3 8FT 18-19 ML - - ---1 14 1 11.8 ... 4 BULR 22-23 ML-CI 0.0 12.0 37.0 51.0 .-1~15 4 14.6 5 8FT 28-29 -- ----- --12.0 6 BULl<30-31 SM-Be 0.0 7.6 44.0 48.4 -2D 14 6 10.5 7 BUL!<36-37 ------- --14.3 8 8PT 38-40 SM+SC 0.0 12.9 45.8 41.3 X IB 13 5 10.6 9 BT..1I.J<46-47 -- -- --- --6.2 10 SPT 58-59 - - -- -----12.3 11 BULl<63-64 --- ------4.4 12 BULl<68-69 - - - --- - - ~.~ .L:S J:jULlI /,j-/4 liM v.v 44.:l ..:SV.:l :l:>.b -.N pn -1-'ast lC ~.o Remarks: LAB TEST SUMMARY ~oring No.HD83-3 Susitna Hydroelectric Project ~~.-~~(I) SUSITNA JOINT VENTURE 1"""'...., d ..JI=E PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«wzu....LIMITS fcONTEN~_II) SIEVE ANAlYSIS (%)Iww0....>-00l:..J ....l ::I:-wUil/)Q..Q..w ........U::l/)~COBBLE GRAVEL SAND SILT/CLAY a:w ....l.l.P.l.PI.Wc (%)=E =Eo..Q..w -«o ....11) ««>-Ww Z..J >-Ww VI VI I-o~::::lU~::I::E l- I 6FT 7-8 8M 0.0 14.4 51.6 34.0 --- - 12.2 2 BuLK 7-9 8M 0.0 30.3 44.8 24.9 -No -PI;:sti - 3 ~17-19 S>1 0.0 8.2 43.7 48.1 --- - 15.0 4 ~ULK 17-19 8M 0.0 17.5 46.2 36.3 '-No -PI;:sti - 5 ~ULK 23-24 8M 0.0 18.6 44.8 36.6 - - -- - 6 ~ULK 31-32 ML 0.0 1.8 27.0 71.2 X 21 18 3 16.7 7 ~ULK 35-36 sw-~8.3 39.2 41.0 11.5 -No -PIc sti '- 8 ~PT 47-49 - - ----- - -- 9 BtlLK 58-59 8M 0.0 24.3 46.5 29.2 -17 16 1 - 10 BULK 60-61 8M 0.0 16.1 37.7 46.2 X 17 14 3 - 11 BULK 73-74 - - - - - -.- - -14.7 12 BULK 77-78 CL 0.0 0.4 11.0 88.6 -28 19 9 15.4 13 BULK 85-86 sc 0.0 25.8 28.3 45.9 X 24 17 7 8.3 14 BULK 87-88 SM-SI.0.0 20.5 43.4 36.1 -19 14 5 - J BORING NO·HD 83-4 1 I; 1 I,... 1 ~, SUS/TNA JO/NT VENTURE 1 1 ~1 Remarks: r f-------------'i·LAB TEST SUMMARY r~oring No.HD83-4 .\:)usitna Hydroelectric Project -'-------------------------------, d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS<l(wz!:,dt;;I LIMITS CONTEN"T w w Ou..>-SIEVE ANALYSIS (%)00:-'_I I-winV'! CL ~~.....1-U:::V'!~COBBLE GRAVEL SAND SILT/CLAY ~wI-L.L.P.l.p.1.Wc (%)~a..W -<0(Cl I-In <0(«>-wW Z -'_>-W w V'l <I'll .....o~::::lu .....I~..... 1 BULI<8-9 SM 0.0 0.0 68.5 31.5 -- - - - (5=2.69 2 BULl<14-15 CL-MI 0.0 1.4 32.6 66.0 X 22 16 5 46.5 3 BID 21-22 CL 0.0 0.5 12.1 87.4 X 31 20 11 74.5 4 SPT 28-30 CL-MI -- -- - 46 28 18 40.7 5 B1D 28-30 ---- - - -- - 44.6 6 BUIl<38-39 MH - - - --53 31 22 30.4 Gs =2.75 7 BUll<41-42 CL 0.0 3.3 18.6 78.1 X 31 21 10 - 8 Bl.JLI<44-45 GW 0.0 59.4 36.3 4.3 ----- 9 BULI<47-48 GW 0.0 67.9 29.4 2.7 --- - 6.4 10 BIll 50-51 SP 0.0 35.4 61.1 3.5 ----8.4 11 BULl<77-78 -- - ---- - - - 12 BUI1<83-84 - - -- - - - - - - 13 Bl.JLI<86-87 8M 0.0 28.2 34.6 37.2 X 18 16 2 9.0 14 BUI1<93-94 SM 0.0 21.0 29.9 49.1 X ---7.0 15 Blll 100-10 GM 5.2 40.6 34.1 15.8 X --- - 16 BULl<110-11 GW 0.0 71.3 24.1 4.6 ------ 17 IPTlT .1<I,23-12 :iSM 0.0 0.0 58.1 41.9 X No fl-Pl flsti ..,- 18 Bt.JLI<129-13 D -- -------- 19 BUll J..35-13 P --- - -- - - - - 20 BULl<J..37-13 B -- - --- - - - - J BORING NO.HD83-5 ) I ; l I l .1 r~ ~ ! 1 !, l I , ~ l1Remarks: I ~----------------':- i LAB TEST SUMMARY \,oring No.HD83-5 .dusitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO.HD83-6 ~. d ~I:E PARTICLE SIZE ANALYSIS ATTERBERG ~MOIST.REMARKS~oCtwZu~LIMITS kONTEN'_V') SIEVE ANALYSIS {%}Iww0....>-o a.::~--'x-winV')a..~~~~U::lIl a COBBLE GRAVEL SA/I.ID SILT/CLAY a.::w~L.L.P.L.I?I.Wc (%):E a..W -oCt o ....1Il oCt <I:>-w W Z --'_>-ww III V')....o~~U~:I::E .... 1 lBuLK 11-15 8M N/A 16.1 46.8 37.1 ----10.5 Gs =2.69 2 BT..JLK 18-20 SM N/A 35.9 36.8 28.3 ----- 3 BT..JLK 24-26 8M N/A 15.4 43.6 41.0 X 17 14 3 - 4 1BUI.J<32-38 CL N/A 10.2 31.0 58.8 ·X 29 20 9 -Gs =2.74 5 BT..JLK 41-43 CL/MI N/A 2.5 8.0 89.5 X 44 27 17 - 6 BT..JLK 46-48 CL N/A 0.2 4.3 95.7 -32 23 9 - 7 BT..JLI<50-51 ML N/A 17.1 23.1 59.8 X ---- 8 BULl<52-54 8M N/A 30.6 42.0 27.4 X -- - - 9 BULl<56-57 GP-G N/A 48.1 40.5 11.4 -- - - - 10 BULl<69-70 SW-~N/A 36.7 52.2 11.1 - - --- 11 BULl<77-79 -N/A - --- - - - - 12 BULl<83-85 GP N/A 68.0 27.5 4.5 - - - - - 13 BULl<86-88 -N/A -- -----.- 14 BULI<91-93 8M N/A 5.8 58.6 35.6 - - - - - 15 BUil 94-96 SM-SJ N/A 4.6 60.4 35.0 -25 21 LJ - 16 BULl 1104-10 ~SM-SJ N/A 0.6 57.0 42.4 -28 22 6 - 17 SPT 108-10 ~-N/A - - - - - - - 26.9 18 BUil ~08-10 ~SM N/A 10.7 56.0 33.3 X - - -- 19 BULl'~:1.l5-11 ~-N/A - - - - - -- - 20 BULf 1124-12 pSM N/A 2.4 58.0 39.2 X 22 2c ,tI.- Remarks: ; ~ ) i J 1 1 1 ! ~ I ) 1 > 1 J 1 1 1 1 1 LAB TEST SUMMARY !)oring No.HD83-6 i dusitna Hydroelectric Project SUSITNA JOINT VENTURE , BORING NO.HD83-6 .. 6 ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~4:wz~t;:;SIEVE ANALYSIS (%)1 LIMITS !cONTEN'w loIJ 0"->-Ocx....-~:J:-w;:;;.." Ql:w~0.o.w I-~U:""~COBBLE GRAVEL SAND SILT/CLAY L.L.P.l.PI.WclWI~:Eo.o.W -oct 01-.." 4:«>-w W 5d~>-W w .."u,I-o!::.:J::E I- '1 IpJ1T.r<l?Ci ,t:;-N/A ------ -- l I I I f I I I Remarks: I J j I -! f""" I ! j J J J J I ..... I I"'"" I, - ,LAB TEST SUMMARY ~oring No,HD83-6 :dusitna Hydroelectric Project SUSITNA JOINT VENTURE :,-----------------------------------------, d ....1::E PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«Wz\din !cONTENTlJ,J1 ou..>-SIEVE ANALYSIS (%)I LIMITSwoeo:..........:I:-W iii <I)"-c-lJ,J ~~':;:<1)6 SILT/CLAY ~~In L.L.P.L.PI.Wc {%)::E ::EQ..Q..lJ,J -«COBBLE GRAVEL SAND««>W W z ....._>WlJ,J VI <I)~a~~Ul-:I:::E ~ 1 BULR 7-8 sp N/A 15.5 81.5 3.0 -- --- 2 BtU 14-16 ML N/A 0.0 14.7 85.3 X - -- - 3 BtJLI<20-28 ML 3.8 19.6 18.0 58.6 --- - 24.3 4 BtU 35-38 -N/A --- - - - - 31.2 5 Bt.JLR 44-47 HL N/A 3.4 21.2 75.4 X - - - 23.2 6 BtILI<55-58 -N/A - - ---- - 24.0 7 BtJLI<61-62 8M N/A 0.0 72.5 26.6 X No 1-Pl ~sti ..2.5 8 BUll<64-68 SM-SC N/A 36.1 54.9 32.5 -18 14 4 1.7 9 BUI.J<75-79 sp-&-N/A 39.4 55.5 5.1 - - - -- - " "'"', I..... 'r BORING NO.HD83-7 ..... I 1 1 L LI 1 1, 1 ! i J 1 i I~ 1 Remarks: J---------------------------------------_--1 'LAB TEST SUMMARY (.oring No.HD83-7 '~usitna Hydroelectric Project SUS/TNA JO/NT VENTURE 1"""''-....., b "'I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~4{wZ~t;I LIMITS tONTENTwl.L1 Ou..>SIEVE ANALYSIS (%)Oct....-..Ii="~ii'ill'ldodow ct.wI-~....W u..1I'I~COBBLE GRAVEL SAND SILT/CLAY L.L.P.L.PI.Wc (%)~do doW -4{01-11'I 4{4{>Wu..3d;:::>ww Vl vI ....0_I:!:.... 1 BULK 6-8 -N/A - - ---- - - 2 ~UI,J<11-13 8M N/A 9.5 61.4 29.1 - - - - - 3 iBULK 16-18 -N/A - - ---- -- 4 aULK 21-23 8M N/A 28.4 51.3 20.3 'X No -PI sti t"o - 5 ~ULK 26-28 -N/A ---- ---- 6 iBur..K 31-33 8M N/A 12.1 68.2 19.7 - - - - - 7 BULK 36-38 -N/A - --- -- - - 8 al.JIl(41-43 -N/A ---- - --- 9 B1JI..J<46-48 8M N/A 19.0 46.6 34.4 -15 14 1 - 10 auLB 51-53 SP-g..N/A 22.6 71.3 6.1 -- - - - 11 BULl<56-58 8M N/A 29.8 53.7 16.5 - -- - - 12 BULl<61-63 8M N/A 9.3 58.4 32.3 X 20 18 2 - 13 BlJLI<66-68 -N/A -.- - -- - -- 14 BULl<72-73 8M N/A 6.0 68.2 25.8 --- - - 15 B1JI..J<75-76 -N/A - - -- - - -- 16 BULI<76 -N/A - - - - --- - I- J BORING NO.HD83-8 i J j l I- ,I_. J J 1 i 1 1 J 1 1 I 1 1 Remarks: ~l c l --..;....-----------------------------------~ LAB TEST SUMMARY noring No ..HD83-8 'Susitna Hydroelectric Project SUS/TNA JO/NT VENTURE -'-'---,-----------------------------------. d .....,':E PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKSR<wZ~t:;;LIMITS CONTENwILla....>SIEVE ANAlYSIS (%)I..........J:-wijiln 000: Q..o..w 1-1-u:::II)~COBBLE SILT/CLAY 00:wI-P.L.p.l.Wc (%):E :Eo..o..W -~GRAVEL S.Afo,IO o 1-11)L.L.<oct>WW Z ....._>W w In II)I-a~~Ul-r:::E1- 1 BULK 5-7 8M N/A ---- -- - - 2 BULK 10-12 8M N/A 33.4 50.7 15.9 X --- - 3 BULl<15-17 -N/A --- ---- - 4 1l3ULB 20-22 8M N/A 38.1 46.6 15.3 - --- - 5 BULK 25-27 -N/A ---- -- - - 6 BULK 30-32 SM N/A 40.2 42.6 17.2 - - - - - 7 BULl<35-37 -N/A - ---- - - - 8 BULl<40-42 8M N/A 16.4 47.1 36.5 X No ~-Pl :1sti ro - 9 BULl<46-48 8M N/A 24.1 44.3 31.6 X -- - - 10 BULI<50-52 8M N/A 30.4 40.7 28.9 -16 14 2 - 11 BULl<56-58 -N/A - - ---- - - 12 BULl<60~2 8M N/A 32.6 48.4 19.0 - --- - 13 BULl<66~8 -N/A - - -- --- - 14 Bl.JLI<70-72 8M N/A 27.5 46.9 25.6 -No t'!-Pl :isti :'"- 15 BUI.J<76-78 -N/A - -- - -- -- 16 BULl<80-82 8M N/A 30.5 43.5 26.0 - -- -- 17 BUI.J<86-88 -N/A -- --- --- 18 BT.JLF 90-92 -N/A - - -- - - 19 BUI...B 95-97 8M N/A 17.2 47.8 35.0 -H:J 15 .,J - 20 B 'Jf -.LU IG -J)J/A - --- - - - Remarks: '~ , 1 1 1 i 1 BORING NO.HD83-9 J 1 'I..... j i ~ 1 I-, f-~ 1-----------------------------------------' LAB TEST SUMMARY i'Joring No.HD83-9 'Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO.HD83-9 '", d "'I~PARTICLE SIZE ANALYSIS ATTERSERG MOIST.REMARKS~O(WzI.::::!lii SIEVE ANALYSIS (%)I LIMITS ICONTENl W W au..>-o a::......r-wi/i<l'la..Q..w 1-1- U::<1'13 COBBLE GRAVEL SAND SILT/CLAY a::wI-l.l.PL.p.1.Wc (%)~~Q..a,.W -0(a 1-<1'1 0(<{>-w W 5di=>-ILl W <1'1 <1'1 I-a~r ~I- 21 BtJIl<05-10 7 SC N/A 15.4 45.1 39.5 X 23 15 8 - L I I... Remarks: t I L 1 l 1 1 l 1 I!!"'" ~ ~l I 1 1 ~ LAB rEST SUMMARY -~Joring No.HD83-9 ~$usitna Hydroelectric Project SUSITNA JOINT VENTURE F""_--,-----------------------------....., d ......:E PARTICLE SIZE ANALYSIS ATTERBERG MOlST.REMARKS~'«WZ~t;,LIMITS iCONTENTLUIJ-j ou..>SIEVE ANALYSIS (%l Oc.::-'-':z:-w in V) 0..o...w t-~ii:V)6 COBBLE SAND SILT/CLAY a.:LU~L.L.p.L.P.1.Wc(%l:E :Eo..o..LU -'«GRAVEL o ~V) '«'«>-LULU Z ....._>-LULU V"l In t-o!::..::lU~:z::E t- Organic Content 1 BULK 3-8 GM N/A 43.7 13.1 - -- ---3.9% 2 ~PT 8-10 CL-ML N/A ----23 19 4 - 3 ~ULK 10-14 GM N/A 44.1 41.9 14.0 - ---- ~ULK GP-G1 N/A .... 4 14-18 57.6 32.3 10.1 -- -- - 5 SPT 18-19 -N/A - - - --- - - 6 IBULK 20-24 CL N/A 0.0 22.1 77.9 X 34 20 14 - 7 SULK 24-28 -N/A -------- 8 SPT 28-29 ML .N/A - - --22 19 3 30.8 9 IBULK 30-34 -N/A - - - --- - - 10 IBULK 34-38 CL N/A 0.0 13.5 86.5 X 32 22 10 - HD83-49BORINGNO.J 1 J 1 J. 1 1 r ,I- 1 1 J J 1 ~ 1 J Remarks: ,I--------------------------------------...... "LAB TEST SUMMARY !1oring No.HD83-49 $usitna Hydroelectric Project SUSITNA JOINT VENTURE r-'--, HD83-S0 d .....1:1:PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~4wz'dtn LIMITS kONTENTU-I ou..>-SIEVE ANALYSIS (%)Iw00'..........J:-w;;;111a..a..w I-~U:::"'e COBBLE SAND SILT/CLAY a:w~L.L.P.L.P.1.Wc (%):I:~Q,.a..w -c{GRAVEL o I-V'l 4 4>-Ww Z .....>-ww V'l V'l ~O~;:)u~J::Ii:l- I j3tJLK 1-4 SM N/A 12.4 47.7 39.9 X No -PI sti r.-Gs =2.70 2 BULK 4-8 -N/A ------ -- 3 BULK 10-13 -N/A - - - ----- '. 4 BULK 15-18 SM-SC N/A 40.5 42.8 16.5 -- - -- 5 8FT 18-20 -N/A - - -- - - - 16.5 6 BULK 21-26 SC N/A 11.4 41.7 46.9 -24 16 18 - 7 BULK 25-28 SM-SC N/A 27.4 44.5 28.1 -20 15 5 - 8 BULK 30-34 SM-SC N/A 29.1 46.1 24.8 -- - -- 9 BULK 35-38 SM-SC N/A 38.8 42.3 18.9 X 20 16 14 -Gs =2.70 10 BULK 40-46 -N/A -- - - --- - 11 BULK 46-48 SM-SC N/A 31.6 48.5 19.9 --- - - 12 BULK 52-54 -N/A - - - --- - - 13 BULK 55-58 SM-SC N/A 27.4 43.2 25.1 -18 14 4 - 14 Bt.JI.J<60-65 -N/A - - - - - - - - 15 Bt.JI.J<65-68 -N/A - --- - - - - 16 Bt.JI.J<70-75 SM-SC N/A 36.5 43.6 19.8 X 18 14 4 -Gs =2.72 17 BULK 75-78 SM-SC N/A 36.1 45.4 18.5 -20 15 5 - 18 SPT 78-79 -N(A - - ----- 19 BOil<80-85 -N(A - - - --- - ~u IJjUU;tl~-(j(j tiC r:ljA .:Ib.4 4.:1.U .GV.b X .G~L:J LV -I\.:1S-=.G·/U Remarks: LAB TEST SUMMARY 40ring No.HD83-S0 dusitna Hydroelectric Project SUSITNA JOINT VENTURE ,....._----------------------------.., d §I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS<wz~t;I LIMITS CONTEN'w w 0""'>-SIEVE ANAlYSIS (%)00<:-'-',J:-wiii Vl Q..Q..w 1-1-ii:Vl a COBBLE SAND SILT/CLAY 0<:wI-L.L.P.L.PI.Wc (%)~~Q..Q..W -<GRAVEL o I-Vl <<>-wW Z -'_>-Ww Vl Vl I-0"'"::JUI-J:~I- 21 SPT 88-89 -N/A --- - ---- 22 aULK 90-95 -N/A ----- - -- 23 ~ULK 95-98 8M N/A 24.6 48.3 26.7 -20 17 3 - 24 RTlT.K 00-10:-N/A -- ---- - - 25 ~ill...K 05-10E 8M N/A 38.4 45.4 16.2 -20 19 1 - 26 SPT 08 -N/A -- -- ---- 27 l3ULK 10-11..1 GC N/A 50.9 36.9 12.2 -23 16 7 - 28 l3ULK 14-lH SM-SC N/A 22.3 36.6 41.4 -- --6.8 I,,'BORING NO.r!HD83-S0 J J J 1 J 1 I 1 f' 1 i 1; 1 l I...- 1 1 1 Remarks: Ii;JL------------------------------------....1 ILAB TEST SUMMARY noring No.HD83-S0 .~usitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO.HD83-51 0 ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«Wz~t;I LIMITS :CONTENTwLLI0"->-SIEVE ANALYSIS (%)OCll'...._.r;:::-wii'ill'l4-0..w U:lI'l~ClI'w~L.L.P.L.p.1.Wc (%)~~Q..~w -«COBBLE GRAVEL SAND SILT/CLAY O~lI'lQ..w Z ...._>-Ww««>-w ....r~~lI'l V,I-0_:::;)U~ 1 BTTr.f.<?-5 -N/A - --- -- - - Organic Content 2 BULK 5-8 -N/A --- - -- - - 2.9% 3 SPT 8-10 -N/A -- -- ---- 4 BULK 10-14 Sp-~N/A 33.5 56.4 10.1 - - - - - 5 SPT 15-16 -N/A - --- -- - 8.7 6 BUI..J<16-18 SM N/A 21.2 54.9 23.9 - - - - - 7 B1LJ.I..J<18-19 -N/A -- - - -- - 11.4 8 BUI.J<20-24 8M N/A 36.9 49.2 13.9 -No p-Pl Flsti ~- 9 SPI'24-25 -N/A - - - --- - 9.1 10 BULE 25-28 SM N/A 9.1 45.1 45.8 -No p-Pl j:lsti ~- 11 BUI.J 30-34 -N/A ---- - - -- 12 SPI'34-35 SM-S(N/A 0.0 69.4 30.6 X - --13.3 13 BUI.J 35-38 -N/A -.-- - -- - - 14 SPT 38-39 -N/A - - - -- - - 14.5 .t'roctor D 1::>::>1 15 BW 40-43 SM-Se N/A 19.6 38.5 41.9 -18 14 4 -max.=136 BULl'45-48 N/A 20.4 39.5 40.1 21 13 9 W opt.=7.316SC--G =2.72s 17 SPT 48-49 -N/A - - -- ---5.2 18 BULE 50-53 SM-S(N/A 14.2 54.9 30.9 -18 14 4 - 19 SPT 55-5E -N/A - -- - -- - 14.5 20 BUU 56-58 -N/A --- ---- - Remarks: LAB TEST SUMMARY r30ring No.HD83-51 Susitna Hydroelectric Project SUSITNA JOINT VENTURE BORING NO.RD-B3-51 0 ~'~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS«wz'::!li';I LIMITS !CONTENTwILlo....~SIEVE ANALYSIS ("10)Oel'...J _.I-win'"Q.a..W ~~U:::"'a COBBLE GRAVEL SAND SILT/CLAY ~~l:i;L.L.P.L.p.1.Wc(%l~~Q"Q"W -«««~W W ~u;:::~ww '"'"I-0""I ~I- 21 8I?T 58-59 ML N/A ----19 16 3 7.4 22 IBULl<60 N/A --------- 23 B'llI.i 64-65 8M N/A 7.9 66.7 25.4 ----- 24 SFT 65-66 -N/A -------9.7 .25 BULE 66-70 8M N/A 0.7 79.9 19.4 -Nc p.-Pl~st'Ie - 26 BULF 70-75 8M N/A 5.5 62.9 30.3 -Nc n-PI ~st'~- I 27 BUll 76-78 SC N/A 18.3 33.8 47.9 -25 IE c - 28 8FT 78-79 -N/A ----- --14.2 29 BULl 80-8:-N/A - ------ - 30 8FT 84-85 -N/A - ------17.0 31 BULl 85-8~-N/A ------ -- 32 8FT 88-8~-N/A ----- --.i~.t 33 BUL 90-9L SM-SI--NjA 9.5 61.3 29.2 -LJ .it - 34 ·SPf 94-9~-~/R.----............ 3:BUL ';;;lb-'::n L:L J.'O/R..j.t "::"l,•..:1 /-e..J.-,J...L(..I.. Remarks: .... J J , J j J J J J 1 J 1, 1 l 1 l j LAB TEST SUMMARY ',oring No.RDB3-51 .Susitna Hydroelectric Project SUSITNA JOINT VENTURE Remarks: BORING NO.HD-83-52 6 ....I~PARTICle SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«wzvI-CONTEN_V) SIEVE ANALYS IS (%)I LIMITSwwou..>00/:.........J:-wViV) CL.o..w 1-1-u:::V)6 COBBLE GRAVEL SAND SILT/CLAY 0/:wI-LL.p.L.P.1.Wc (%)~~o..o..W -«ol-V) ««>wW Z ...._>ww Vl Vl I-o~:::lUI-J:~I- 1 ~tJLK 3-8 SP-SJ N/A 39.5 50.6 9.9 - - -- - 2 SPT 8-10 8M N/A 9.1 67.7 23.2 --- - 5.1 3 BtJLK 10-14 SM N/A 39.5 46.7 13.8 X No IJ.-Pl sti ~- 4 SPT 14-15 8M N/A 22.3 58.6 19.1 -- - - 6.1 5 BULR 16-18 8M N/A 31.3 55.1 13.2 X No -PI sti i"'- 6 SPT 18-19 8M N/A 20.5 53.1 26.2 -- - - 7.2 7 BULK 20-23 GP-G N/A 47.2 41.3 11.5 --- - - 8 SPT 24-25 -N/A ---- ---5.2 9 BULK 25-28 SM-SC N/A 32.4 48.1 19.5 - - -- - 10 SPT 28-29 -N/A - - - - ---- 11 BULR 32-34 SM N/A 25.3 47.9 26.8 ----- 12 SPT 34-35 8M N/A 1.9 57.4 40.7 - - - -7.5 13 BULR 35-38 -N/A - - - - - - -- 14 BULK 40-43 SM N/A 27.4 47.5 25.1 -16 14 2 - 15 8PT 44-45 8M N/A 5.5 57.8 36.7 - - - - 8.2 16 BULK 45-48 -N/A - - - - --- - 17 SPT 48-49 -N/A -- - - -- - 3.6 18 BULR 50-53 8M N/A 28.2 44.6 27.2 -16 14 2 - 19 SPT 54-55 -N/A ----- - -14.1 20 BULl<55-58 -N/A - -- - - - - - ---_...-----........;--------------------, J ..J , j 1 J J } [I, ,.... ~ j j " 1 J 1 J 1 j -,;..,.--------------------------------------' LAB TEST SUMMARY noring No.HD83-52 Susitna Hydroelectric Project SUS/TNA JOINT VENTURE BORING NO.HD-83-52 0 ~I~PARTICLE sizE ANALYSIS ATTERBERG MOIST.REMARKS4:wzul-CONTEN'_I/) SIEVE ANALYSIS (%)I LIMITSWILlo~>-Oat:....._.:I:-wUiI/) 0...0..W 1-1-i:i:1/)5 COBBLE SILT/CLAY IX wI-L.L.PL.PI.Wc (%)~~o..o..W -«GRAVEL SArIlD oI-l/) 4:«>-W W Z ....._>-ww lJ'l I/)I-o~:::lUI-:I:~I- 21 SPT 52-60 -N/A ------ - 8.6 22 ~60-63 SM-SC N/A 27.6 42.9 29.5 -18 14 4 - 23 SPT 64-66 ML-cI N/A -- --20 15 5 9.4 24 BULK 66-68 SM N/A 35.6 41.9 27.5 - - --- 25 SPI'68-69 -N/A --- ----- 26 BULK 70-73 -N/A --- --- - - 27 SFT 74-75 -N/A - - --- -- - 28 BUL~75-77 ..l.N/A - - - - - - - - 29 BULl<81-83 -N/A - - - - ---- 30 BULl<83-86 SC N/A 21.8 43.5 35.0 -25 14 11 - 31 BULl<86-88 -N/A ---- -- - - 32 SPT 88-89 -N/A --- - - - - - 33 BULI<90-93 -N/A - - - -- --- 34 Blf.1I.J'95-98 -N/A --- - - --- 35 SI?T 98-99 -N/A - - -- -- - 6.5 36 BW 100-10 38M N/A 39.6 42.0 18.4 X Nc p-Pl asti p - 37 BtJLI<105-10 3 - N/A - -- - --- - 38 SPTl 08-109 -N/A - - --- - - - 39 BUI.J<l10-11 3 -N/A - --- -- - - 40 BUI.J<lIS-II 8 SM-SC N/A 31.1 44.6 24.3 --- - - J J J j ~l J J J J J J 1 1 1 i I 1 1 Remarks: 1---------......1 LAB TEST SUMMARY 00ring No.HD83-52 Susitna Hydroelectric Project SUSITNA JOINT VENTURE -------------------------------------------., 6 ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~.o:(wz~lii LIMITS IcONTEN1ILlo~>SIEVE ANALYSIS {%}IwOOli:-'-':I:-wii'j<l'l 0-0..W 1-1-Li:<I'I~SILT/CLAY ~~lii p.L.Wc (%)~~....a..W -.0:(COBBLE GRAVEl SAND L.l.p.1. .0:(.:(>WW SCi=:>ww <1'1 <1'1 I-o~:I:~I- Al brrTr<1 Q ••1 ')1 c::M '1\1 In.~~Q c:;n ')lC:;Q -- - -- Lt.')RTrr ,J("':1_1 '),-Min.-- --- - -- 43 &"PI'28-12'SC N/A 6.4 52.4 41.2 -31 17 14 9.1 '. 44 :stJLK 30-13 SM N/A 26.4 47.8 25.8 -NOl -PI,sti - 45 lRTrr .R'35-13 -N/A -- - ---- - 46 8PT 38-13<CL N/A --- - 34 17 17 7.7 47 P.TTT.K 40-141 SL N/A 22.4 41.3 36.3 X 26 14 12 - 48 AlIT ,J<:50-15 SM N/A 13.3 67.3 19.4 X No -PI sti I-- 49 --- - - ------- 50 ---- - ----- - - - 51 BULK 55-151 8M N/A 12.2 68.7 19.1 X No ~-P1 sti r._ 52 BOLK iL 6O-16 -N/A - ---- - -- 53 BULK ~65-16 ~8M N/A 15.3 70.2 14.5 -No ~-P1 sti '"- 54 BULK ~70-17 ~-N/A -- - - - - - - 55 BULK 1175-17 "SM N/A 10.2 64.8 25.0 X No II-PI sti ...-Gs =2.81 56 B~~80-18 SW-~N/A 40.1 51.8 8.1 X 17 14 3 -Gs =2.77 57 Bt.JLI<1L85-18 PSM N/A 9.0 72.6 18.4 X No I1-P1 sti ...- 58 Bt.JLI<~90-19 b CL-Nl N/A 16.4 31.6 52.0 X 23 17 6 -G5 =2.82 59 Bt.JLI<1195-19 a -N/A -- -- - -- - 60 BULB ~00-20 ~CL N/A 0.0 21.7 78.3 X 29 19 10 - BORING NO.J J J 1 r J J 1 J , J j I I j I 1 l 1 1 1 Remarks: j HD83-52 LAB TEST SUMMARY """"30ring No.HD83-52 Susitna Hydroelectric Project SUSITNA JOINT VENTURE II"'"'" 1 BORING NO.RD-83-52 0 ~I~PARTICLE SIZE ANALYSIS REMARKS I «w ATTERBERG MOIST.z ':::!ti LIMITS IcONTENlIJ.I ou..>SIEVE ANAlYSIS (%)I 1 w Oc.::...........::r::-wiiill'lQ..Q..w 1-1-ii:1I'l~SILT/CLAY .l¥w P.l.P.l.We (%)~~Q..Q..W -«COBBLE GRAVEL SAND 01-ti L.L. ««>WW Z ....._>ww <I'l <I'l I-o~:::JUI-::r::~I- 1 fil BULl<~05-20 ~SM-SC N/A 6.3 46.8 -22 18 4 - 62 SPT ~08-20 bSM N/A 7.4 75.6 17.0 -- --13.2163BULF~10-21 I>SW-SIl N/A 17.5 73.5 9.0 -No ~-1'l i'l.sti r.._ l 64 BULF ~15-21 a S1'-8I)N/A 0.7 89.4 9.4 .--- -- 65 SPI'~18-21 ~8M N/A 0.0 86.8 13.2 -- --- 1 66 BULl<~22-22 ~-N/A ----- --- 1 67 BULl<~25-22 aSM N/A 13.6 68.1 18.3 -No 11-1'1 iisti P - 68 SPI'~28-22 gSM N/A 0.0 55.5 44.5 - -- - 20.5 1 69 BULl'1230-23 I5SM N/A 14.2 66.7 19.1 --- -- 70 BULl'1235-23 S -N/A - -- -- - --1 71 SPT 238-23 ~SM N/A 13.8 68.7 17.5 - ---6.1 1 72 BUU 1240-24 pSM N/A 29.5 52.0 18.5 - - - -- 73 BlJ1J'~45-24 B -N/A - --- ----. 1 74 SPT 248 8M N/A 37.6 53.6 8.9 - - - - - 1 75 BUll 1250-25 5SM N/A 27.8 56.3 15.9 - ---- 76 BULl 1255-25 ~-N/A -- - - - - - - I 77 -.- - ---- --- - -- 78 I BULl ~58-2E ~SM N/A 32.5 45.7 21.8 -Nc p-Pl ~stj k:- 1 .. 79 BULl 1261-2E ~-N/A -- - -- --- 1 80 SPT 268 8M N/A 23.9 63.8 12.3 - - - - - 1 Remarks: 1 L.AB TEST SUMMARY ~oring No.RD83-52 dusitna Hydroelectric Project SUSITNA JOINT VENTURE rrm I BORING NO.RD-B3-52 F d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS<{w Z u ....CONTEN-'"SIEVE ANAlYSIS (%),LIMITSww0....>-O~I -'-'::c-WV;1Il Q,.Q,.UJ ........iL:1Il~COBBLE GRAVEL SAND SILT/CLAY CI'UJ ....L.L.P.L.p.1.Wc (%)~~Q,.Q,.UJ -<{o ....V'l F <{<{>w UJ 3Gi=>ww i III III I-o~r ::IE l- f 01 IOT"lTtI nc::o.•'}"7 .C:M lo.T/1i ':l7 '}l:;,{)h l??1\Tt"'I _01 ,cd-i-I II 1 0")lor "ITt<n7A_'}7:-MI1i - - --- - -- ,q3 1/78-27 ~-N/ASPI'- -- -- - - - 1 84 BUI..J<t278-28 8M N/A 21.8 64.3 13.9 ·X - - - - Gq =2.74 I 85 BULl't282-28 I>-N/A --- - ---- ~86 BULl'1286-28 ~sp-g N/A 39.4 50.2 10.8 -No I1-Pl Flsti P - I ,q7 BOLF 1?,q,q-29 I>_N/A - - - - - ---.... 88 BUU 1295-29 ~Sp-g N/A 35.3 54.0 10.7 ----- 1 89 SPI'1298 -N/A -- - - -- - - L 90 BOLF 1298-30 ~-N/A - - - --- -- 91 BlJIJ 1302-30 17 GP-Q N/A 47.5 42.1 10.4 X No p-Pl FtstiI::- 1 92 BlJIJ 1307-30138M N/A 31.2 47.7 21.1 X Nc p-Pl Ftsti I::- 93 SPT 308-30~-N/A - - -- - - .,..- I.... 1 I 1 L ~ l I , Remarks:L L 'LAB TEST SUMMARY ~oring No.RDB3-52 dusitna Hydroelectric Project SUSITNA JOINT VENTURE d ~I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS<(w Z u~CONTEN_II) SIEVE ANALYSIS (%)I LIMITSwwOu..>OCl'..........:I:-wiilll)a..a..w ~~U:::1Il~COBBLE GRAVEL SAND SILT/CLAY CI'UJ ~L.L.p.L.p.1.Wc [%)~~a..a..w -<(o ~II) <{<(>Ww Z .....>ww II)lI).....0.':::.;:)ui=:I:~..... lA P3IJLK 10-19 8M 0.0 13.4 73.2 13.4 -- - -- 1 IBULK 19-22 8M 0.0 18.3 53.6 28.1 -16 16 0 - 2 - ---- - - -- - - 3 BOLK 30-32 sc-g,0.0 27.2 31.9 40.4 .X 22 16 6 -Gs =2.72 .4 BtJLK 36-38 sc 0.0 30.6 33.6 35.8 X 25 15 10 - 5 SPI'38-39 GC 0.0 39.3 25.7 35.0 X 36 17 19 12.6 6 BULK 45-47 sc-sr-0.0 28.2 43.5 28.3 X 20 14 6 -Gs =2.71 7 BULK 57-58 -- - - ------ 8 BULK 60-62 sc 15.8 26.4 35.4 22.4 -24 15 9 - 9 BULK 66-68 -- - -- - - - -- 10 BULK 70-72 sc 0.0 33.2 40.6 26.2-X 21 13 8 - 11 BULK 66-68 --- - ---- -- 12 BULl<80-82 sc 0.0 29.3 44.1 26.6 -19 11 8 - 13 BtU 86-88 - ----- - - - 1A OTlT 1<on._0'"C!"'n n An 1 Ll1 A lA 1 -??14 A - 11:;RITrJ'qf;-qA ------ - --- 16 BULF tLOO-I0 ~GC 0.0 36.4 34.3 29.3 -22 14 8 - 17 BULl'tL06-10 a --- - - ----- 18 BtJI1'ill0-ll ~GC 0.0 42.4 27.9 29.7 -25 16 9 - 19 BtJI1'tL16-11 ~-- -- - ----- _1_BORING NO._HD83-53 ~ 1 L L L L Remarks: ~----------------....;...---------------------..... 1 1 L 1 I~ 1 I.... 1 1 'LAB TEST SUMMARY I""';oring No.HD83-53 ~usitna Hydroelectric Project SUS/TNA JO/NT VENTURE ...- d ....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~«Wzu~LIMITS CONTENT_V) SIEVE ANALYSIS (%)Iww0""'>00.:........r-wii'iV) ~~w ~~U:V'l~COBBLE GRAVEL SAND SILT/CLAY 0.:w~L.L.p.L.p.l.Wc(%l~~~~w -«o ~Vl ««>WW Z ...._>ww V'l V'l ~0"'"::>U~r~~ ,20 PTlTJ(20-12~SM-SC 0.0 20.2 48.3 31.5 -20 15 5 - 21 bnTU 26-12~------ - --- 22 aULK 30-13'SM-SC 0.0 35.2 39.8 25.0 -19 14 5 - 23 l3ULK 39-14(GC 0.0 67.5 20.3 12.2 ----- 24 BULK 46-1~GW 16.9 49.7 28.4 5.0 X 20 15 5 -Gs =2.69 1 BORING NO.HD83-53 1 1 1 '1 1 1 f,- 1 Remarks: ~ ~ 1 t 1 I '"'"'III r"'"'-'---.------------------------------------....i 'LAB TEST SUMMARY noring No.HD83-53 ~usitna Hydroelectric Project SUSITNA JOINT VENTURE ,....,--_._----------------------------, d -'I:::Ii PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~-«wz~lii 1 LIMITS CONTENwwClLL>SIEVE ANALYSIS (%)DOC:-'-':I:-Wi/;VlQ.Q.w ........i:i:Vltj COBBLE GRAVEL SAND SILT/CLAY ~~lii L.L.P.l.p.1.Wc (%):::Ii :::IiQ.Q.w --«-«-«>WW 5 d;=>ww Vl Vl ....Cl·~:I::::Ii .... 1 !BULK 3-5 8M 0.0 20.9 51.6 27.5 - - - - - 2 iBUL1"8-10 8M 0.0 24.6 44.2 31.2 ---- - 3 BULK 13-15 8M 0.0 16.9 44.2 33.9 -Non PIa I>tic 4 BULK 18-20 SM·0.0 8.8 48.5 42.7 ----- 5 IBULK 23-25 - -- - - -- --- 6 BULK 28-30 SM 4.8 31.3 41.6 22.3 -- - -- 7 BULK 33-35 SM-3:.0.0 28.6 43.4 28.0 -19 14 5 - 17.8 49.4 32.8 8 IBULK 38-40 8M-&0.0 19.5 47.8 32.7 -18 14 4 -Gs =2.72 16.3 46.8 36.9 9 BULK 43.45 SM 0.0 15.1 45.8 39.1 ----- 10 BULK 48-50 8M 0.0 17.1 53.2 29.7 --- - - 11 BULl<50-51 8M 4.0 17.3 39.5 39.2 - -- - - 12 BULI<57 8M 0.0 8.2 53.3 38.5 - --- - 13 BULI<60-61 8M 0.0 24.8 45.8 29.4 -- --- 14 BULl<70-71 8M 0.0 12.2 38.8 49.8 -- - -- 15 BUI..E<78-79 ML 0.0 1.1 10.6 88.3 _.- - -- 16 [BUI.J<82-83 ML 0.0 2.5 26.7 70.8 ----- 17 BUI.J<88-89 8M 0.0 23.7 40.1 36.2 --- - - 18 I BI.JLI<93-94 SM 0.0 4.4 46.3 49.3 --- - - , ~ ~ ~LRemarks: l ! 1 BORING NO.wwff3 L 1 L L , L L L L L L I L l LAB TEST SUMMARY roring No.wwff3 Susitna Hydroelectric Project SUSITNA JOINT VENTURE d ....I:i PARTICLE SIZE ANALYSIS ATTERBERG MorST.REMARKS~«Wz~ti !CONTENTSIEVEANAlYSIS(%)1 LIMITSww0....>-o Or:........::I:-~Vi'"0-O-w 1-1-....."b COBBLE SAND SILT/CLAY Or:WI-L.L.P.L.p.1.Wc(%l~~O-O-LU -«GRAVEL 01-."««>-LULU 5d~>ww ."."I-o~::I:~I- .19 BULK.98-99 8M 0.0 27.2 24.8 43.0 - - --- .20 ~TlT .f("'03-10t:GM 0.0 41.4 38.9 19.7 ----- 21 RIly.K 08-1Dc 8M 0.0 25.0 43.7 31.3 - ---- 22 BULK 12-11 8M 0.0 19.8 45.5 34.7 - -- - - 23 BULK 18-11"8M 0.0 5.1 616 33.3 ----- .24 ~ULK 23-12~8M 16.9 18.7 44.8 19.6 ----- 25 IPITT J<"28-12<GM 0.0 40.4 39.2 20.4 - ---- 26 aULK 34-13 1 8M 0.0 27.6 53.4 19.0 ----- 27 IPrTT .K 37-131 GP-G ~0.0 64.4 30.3 5.4 - - -- - 28 ~TlT .K 43-14<CL - ----143 23 20 - \ IPrlT .K29 56-15 ML 0.0 1.1 43.5 55.4 ----- 30 IBULK 575 ML 0.0 0.3 39.1 57.4 - - --- 31 ~TlT.K 59-16l 8M 0.0 19.1 72.4 18.5 ---- - 32 BULK 61-16 8M 0.0 17.7 51.0 31.3 --- - - 33 IPTlITU 64-16 GP 0.0 48.3 46.8 4.9 - - --- GM 0.0 47.8 37.7 14.7 ----- 34 'PT'IT .f("74 17 -- - - ------ 35 IRHTX 75-17 -- ---- - --- 36 Blrr.J<76-17 --- -- - -- - - 37 IPTTT.U h77-17~--- -- - - --- L, I 1 L J t.... '~ 11'.... I~ L Remarks: .l 1 BORING NO.wwfl3 I'.,'t~ 1 1,- 1 t· j~ 'tAB TEST SUMMARY r~;oring No.WWfl3 SUsitna Hydroelectric Project SUSITNA JOINT VENTURE d .....I~PARTICLE SIZE ANALYSIS ATTERBERG MOIST.REMARKS~4:wZ~l:;;I LIMITS 1c0NTENwwou..>-SIEVE ANAlYSIS (%)001:.....-'J:-wu;1J'l 0.o..w ~~Li:1J'l~COBBLE GRAVEL SAND SILT/CLAY OI:W~lol.P.l.p.1.Wc(Ofo)~~o..o..W -4:o ~V'l 4:4:>-W W Z ....._>-w w IJ'l <I'l~ou..::;)U~J:~~ .~8 RlTf.K 81-18 --------- - 39 InTrr .f,(85-18l --------- - 40 ~rr.f,(87-18;---- ----- - 41 bTlT .U 90-19 --- ------ - 42 IOTrru 93-19 - -- - - - ---- 43 I~TT .f,(98-19 - - - -- --- - - 44 BULK :>03-20 --- -- ---- - wwlt3 Remarks: BORING NO.Ii'-" " ~ J f- J j 'f: ~ l ~ J r~~ 1 1 1 1 , 1 1___•....1 LAB TEST SUMMARY -loring No.wwlt 3 Susitna Hydroelectric Project SUS/TNA JOINT VENTURE r I 3.GRADATION CURVES 3.1 River Channel 3.1.1 Main Dam 3.1.2 Upstream Cofferdam 3.1.3 Downstream Cofferdam 3.1.4 Portals 3.2 Relict Channel r I l r I ! r ~' r I r I ~ I I 3.1 RIVER CHANNEL '1 1 1 )1 1 }J GRADATION SIZE ANALYSIS I U.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer, 12 9 6 2 1 pn 1 3/4 11'3/B 4 10 20 40 60 BO 1 0140 200 270 100100..'"I ...I I I LEGEND f\1'\WEIGHTED AVERAGE 9090\\.I,- - -UPPER/LDWER RANGE f\.\.,8080.--- 1\, \:"- 7070,\I, ,~,,60 .. .0:::~60 -'"""r\-IIco1\:- !\",-II "1\...;a 50 on:::50 ~..I\.r-....IIL0:II 1\"'-i:<:1\40i:40 -~1--...I"-..,c: II...-t:<:_. r"":II ,1""-.30 II~"""...II 30 \.,.~1'-........ 'r-.......................2020"t-....r--,-~"- ...........i""'--""'-.1010'r-...-"'---~I-lo- 0.001 001005010510.5 0.1 0.05 0.01 0.0051000SOD Grain Size in Millimeters I I GRAVEL SAND FINES IBOULDERSCOBBLESICoarseFloeCoarseMediumIFineSl1tSizes1:'ay SizeS! LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +3/4"CLASSIFICATION (Us C)ALASKA POWER AUTHORITY MAIN DAM HD8J J9 20.8 WE LL GRADED SANOY GRAVEL (GW-GM) SUSITNA HYDROELECTRIC PROJECTCENTERLINE1013. 42-46 W AT ANA DEVELOPMENT RIVER CHANNEL ;OMMENT:48'OF SAMPLE DAM AXIS FDN.AREA SANDY GRAVEL GRADATION llUl.lJHMtlC~1 DAre ~F/fiVRC 'U$J'NA JOIN'W'N'U"AUG 1983 01 ']')}']1 1 J 1 1 I 1 '1 ).J GRADATION SIZE ANAL VSIS u.S.Standard SIeve OpenIngs In Inches U.S.Standard Sieve Numbers Hydrometer/ 12 9 6 ~2 1 12 1 3/4 11 3/8 4 10 20 40 60 801 0140 200 270 100100f-;"'"""'t.. , "t..LEGE N0 f\!'."'~WEIGHTED AVERAGE 9090- ~I\.I---'---UPPER/LOWER RANGE 'r-..,."-1'01-8080\I....... ~ "-..........1\7070 r-...""'...... 1\~1\, 60 ... .<:~60 -'"1\I't\.1\~......';s.. t'...,..,;s r-...1\50 "Q:;;50 1\,""-1\Lt\.....c;.. ""'" ,... i'..i:c; 40;::40 ..'\,1\.0::....0::~..,.,..~30 30 ......~\,\... ,"-'\2020r"\"-~'".... 1010r....."'"10-...r-I-- 0.00,00 50 10 5 1 0.5 0.1 0.05 0.01 0.0051000500100 Grain Size in Millimeters I I GRAVEL SAND 1 FINES IBOULDERSCOBBLESrCoarseFIneCoarse1MedIumIFIneISIltShes1:'lay Sfze~ LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +3/4"CLASSifiCATION (USC)ALASKA POWER AUTHORITY MAIN OAM HO 83 10,18 12.8 POORLY GRAOEO GRAVELLY SAND, SUSITNA HYDROELECTRIC PROJECTCENTERLINE11,13,42 45 (SP SM) WATANA DEVELOPMENT RIVER CHANNEL COMMENT:72'OF SAMPLE DAM AXIS FDN.AREA GRAV.SA_NO GRADATION /l.llI1.UH~a:~1 "DAfe ~I " FlfiVIlE I ..",~.A,N'.h,,,",AUG 1983 02 ])1 1 CCC]'J J J 1 )CI CC I )1 J GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer, 1 Z 9 6 2 1 P/2 1 3/4 1/3/8 4 .10 20 40 60 801 0140 200 270 100100.~~" •LEGEND '\~.WEIGHTED AVERAGE 9090 \1\,\.- - -UPPER/lOWER RANGE 80 l\1\80, 70 1\\\70 \\, \\60 ... ~60 .I:,\\-0\ ~.....--.;II..'\"\;JI.>, l:50 -50 ..c ~.\1\....... 0:::..\.\-0:::~;::40 --1--------r--40 ......0::: \..."-~AI \1\1:30 .. 30 "".. ",I"~""r... I'\.i''....2020I.........,...............- 10 ...........~,...10""-r-r--1-00 ...-~-1--. I"--I-0 r--.~-0,001 0 1000 SOD 100 50 10 1 0.5 0.1 0.05 0.01 0.005 Grain Size in Millimeters I I GRAVEL SAND.FINES IBOULDERSCOBBLESICoarseFineCoarseIHedlumISiltShes~lay Slze~Fine i LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +3/41'CLASSIFICATION (USC)ALASKA POWER AUTHORITY UPSTREAM HD83-37'8.I8 /0 39.4 WELL GRADED GRAVEL.(GW) SHELL ~tJSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RIVER CHANNEL COMMENT:4/'OF SAMPLE AREA U/S OF DAM AXIS GRAVEL GRADATION IlMIlJl'EMl:J a;0,I ()ATe "~l/RC '",,'~.JO,~r .'N'"",AUG 1983 03 ,. --1 'J ---1."1 ')1 1 -J '1 }1 J 1 I J j GRADATION SIZE ANAL VSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer, 12 9 6 2 1 /2 1 3/4 1/23/8 4 10 29 40 60 8010140200 270 100100l"-I' I I LEGE N0 "I',WEIGHTED AVERAGE 9090l\~I"-----UPPER/LDWER RANGE \...."8080r\I'\ l\, 70701\f',\"\60 ....s:~60 DO DO ~,\~-;-;)I.. \\>,;Jl \.50 .0~50 '\1\,......<:.."-<:,'-"- i:40 r-...40 ...\i'\".<:.....<:~.. "1'-...........b 30 30 ........"1"'-- 20 1',I"..i'o 20r"....... I.......... 1'-...."'r--k ~..1010r--roo r-- r--r--1- 0.001 0010050105I0.5 0.1 0.05 0.01 0.0051000500 Grain Size In Millimeters I I GRAVEL I SAND FINES IBOULDERSCOBBLESICoarseFineCoarseIMediumIFineSiltShes~Iay Slz~~ LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +;V4"CLASSIF!CATION (Us C)ALASKA POWER AUT/-IOFlITY /PSTRFAM HD83 37-39 25 23.5 WELL GRADFD SANDY GRAVEL.- rGW-GM)SUSITNA HYDROELECTRIC PROJECTSHELL WATANA DEVELOPMENT RIVER CHANNEL :OMMENT:'97'OF SAMPLF AREA U/S OF DAM AXIS SANDY GRAVEL GRADATION 'l,ljnIJl'EMIl~Drl OArC I F'GVIIC,"",.."".,v,.,,,.,AUG 1983 04 1 1 J --,-1 -]J --J ----1 -1 I J J ]1 ) GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer, 12 9 6 2 1 P/2 1 3/4 1/3/8 4 10 29 40 60 8010140200270 100100.....II !I ~LEGE N0"-.~ '"r-."",,-.-"- WEIGHTED AVERAGE 9090r;;;;:~~---UPPER/LOWER RANGE.... ~~\8080""i\.",i\7070 1\ \~\60 ...r.~60 -0':,1'\-t.......t>I ;a--..1\.'...........50 >,:II ..0E50, 1'.."""""... ......c..'"l"':"i:r: 40i:40 -1--... """""....."""-.r:u... -I--~r:.....u ~. 30 OJ ,~.....30 r--,I'-~~... ~~2020~,r--.::::I........~ "~1010-"''-- 0 0.00\01005010510.5 0.1 0.05 0.0\0.0051000500 Grain Size in Millimeters I I GRAVEL SAND FINES IBOULDERSCOBBLESrCoarseFlneCoarseMedIumIFIneSIltSizesl:1ay SIz~~ i ~,..-.--.-LOCATION BORING NO.NO.OF SAMPLES %FRACTURE -t-3/4"CLASSIFICATION (USC)AU\SKA POWER AUTHORITYUPSTREAMH083-38,39 3 /5.6 W£LL GRAO£O GRAVELLY SANO. (SM)SUSITNA HYDROELECTRIC PROJECTSH£LL WATANA DEVELOPMENT RIVER CHANNEL COMMENT:9'OF SAMPLE AREA U/S OF DAM AXIS GRAVELL Y SAND GRADATION 1J.~tWHMtla;Q)r I DAre FJGL:/IC '."'0'..,,,...,.,.",AUG 1983 05 1 )J J ~~...)·1 1 1 .1 ..~..]1 J ..)·1 I GRADATION SIZE ANALYSIS u.S.Standard SIeve OpenIngs In Inches U.S.Standard Sieve Numbers Hydrometer, 1Z 9 6 3 2 11/2 ,3/4 lIZ 3/B 4 10 20 40 60 BO 100140200 270 100100, ~,~.•, LEGEND \I'1\WEIGHTED AVERAGE 9090, \_ - - _UPPER/LOtVER RANGE,1\\8080 I' , I\.1\1\7070"\"'\.\,60 ... .I:~60 '".\\&;'"-;Jl-AI \\\>,;Jl 50 .0£50 \\'.. IILCAI \\r\...c 40i:40 ...,1\.C AI... I--~"AI l'30 ..~0...30...1'\1\. 20 -I\."l'20 I'"""'---... "~""'"10Ilo..10-..10 '.r-...-.......!to r--•......,. 0.001 001005010510.5 0.1 0.05 0.01 0.0051000SOD Grain She in Millimeters I GRAVEL I SAND T FINES IBOULDERSCOBBLESICoarseIFineICoarseMediumIFineISiltSizes~lay SIz~~ LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +3/4"CLASSIFICATION (Us C)ALASKA POWER AUTHORITY NO 1)3-11,/9.7 3ae WELL SRAOED GRAVEL,(6W)""'-'JPSTREAM SUSITNA HYDROELECTRIC PROJECT~OFFEROAM 20.21,a 22 WAT ANA DEVELOPMENT RIVER CHANNEL ;OMMENT:24'OF SAMPLE U/S COFFERDAM FDN. .GRA VEL GRADATION Il.lltUJHMD~~1 'wc I FlGIIRC""""""N'.IN'''",AUG 1983 i 06"'_......,- ~l '1 --1 ..~-1 1 1 )1 ]1 J 1 1 -J GRADATION SIZE ANALYSIS u.S.Standard SIeve OpenIngs In Inches U.S.Standard Sieve Numbers Hydrometer/ 12 g 6 2 1 /2 1 3/4 1/2 3/8 4 10 20 40 60 8010140200 270 100100,...."~"-I LEGEND 1\1\I\.WEIGHTED AVERAGE 90901\- - - -UPPER/LOWER RANGEI\.1\ \I\.I'8080 I\.1\ 1\\\7070 \\.~,\60 .. 1' , ..c~60 ""I'~"",,-'"""=-- >.'"i\"50:II .......Cl};50 \I ......... ..~'"c;;L "----i:"~40 c .:40 -....~.......'"".."~c -"-"1'-30 "e r\.....30 I'""- 1',... "I'I'2020r-.....~"I'-. 10 I'......."'"10 "'1--0 --1"'-:--1-.. 0.001 0a 100 10 5 1 0.5 0.1 0.05 0.01 0.0051000SOD50 Grain Size In Millimeters I I GRAVEL SAND I FINES JBOULDERSCOBBLESICouseFineCoarseMediumIFineIS11tSizes~1ay SIz~~ LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +3/4"CLASSIFICATION (U S C)ALASKA POWER AUTHORITY UPSTREAM HD8~/1-2~~2 25./WELL GRADeD SANOY GRAVEL, SUSITNA HYDROELECTRIC PROJECTCOFFERDAMa4/(GW-GM) WATANA DEVELOPMENT-! RIVER CHANNEL U/S COFFERDAM FDNCOMMENT:99'OF SAMPLE SANDY GRAVEL GRADATION ll.lleUJHMI'JC~1 OATE f/{iIJlle lu,,'.A "',.,.1.",,,AUG 1983 07 CJ -1 cJ 1 C)c---J 1 -)1 )1 CJ 1 1 1 J GRADATION SIZE ANALYSIS u.S.Standard Sleye Openings In Inches U.S.Standard Sieve Numbers Hydrometer/ 12 9 6 2 I /2 1 3/4 1/3/B 4 10 29 40 60 BO 1 0140 200 210 100100i"-I': LEGENDI',~i"",WEIGHTED AVERAGE 9090r,- - - -UPPER/LOWER RANGE 1'-"-I'8080t'.r'\'\ '\'~\7070 I''-'~ .....~60 ..I',.c: DO~fiO l\,~........0;'"I'...;Jl~"-.'"50 >0:II ,Q:::50 r-.....'"....a-..c:I- OJ ""r--, 40 ""c:...i:40 - 'i'\.~.\.c: OJ... l::c: OJ "1\'\30 ..~30 ... "-.'"1'\, '\... 2020 """- '"......... ""'-1010r-.....I'---..~ 0 I 0.001 01005010510.5 0.1 0.05 0.01 0.0051000500 Grain Size In Millimeters I I GRAVEL SAND I FINES IBOULDERSCOBBLES-~hy Slz~~I Coarse Fine Coarse Medium Fine Silt Sizes I LOCATION BORING NO.NO.OF SAMPLES 0/0 FRACTURE +3/4"CLASSIFICATiON (USC)ALASKA POWER AUTHORITY IIPSTREAM HD83 /8 /1.2 POORLY GRADED GRAVELLY SAND SUSITNA HYDROELECTRIC PROJECTCOFFERDAM/7-23,84/(SP-SM)WATANA DEVELOPMENT .RIVER CHANNEL ..........-U/S COFFERDAM FDN.COMMENT:47'OF SAMPLE GRAVELL Y SAND GRADATION 'OC"__••_,__ IIMIUl'E~tlll:~1 DAre l ..FifiVIU ,•.-,...10'.'.,..,."AUG 1983 ..08 -.--._~~~---_. 1 1 e-l .--J 1 )1 1 1 J ]]1 ]1 ]1 ) GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer / 12 9 6 2 1 /2 1 3/4 1/3/8 4 10 20 40 60 801 0140 200 270 100100,. LEGEND--I-...r-i"--t--r-I~ !""I'~r---r-~1'---WEIGHTED AVERAGE 901-_ 90 1'1'1'"t"'-- - - -UPPER/LOWER RANGE I ....r-.....1\8080...............t'-. '...."-\7070"'...r--.\ 1\, 60 ..\.c '"~60 ~\';;'"::a---\ ., 50 >,:JI A};50 1',\..., c..,\i:.. 40c "i ..;:40 -\.c.,...\~c \.,.. '\30 "'"~..30 \1\\A. -1\\'\2020\'"1\.'1010"-, ....... 0.001 0010510.5 0.1 0.05 0.01 0.005100050010050 Grain Size in Millimeters I f··- GRAVEL .SAND I FINES IBOULDERSCOBBLESCoarseFineCoarseMediumFineISlltShes~lay Slz~~ LOCATION BORING NO.NO,OF SAMPLES %FRACTURE +-3/4"CLASSIFICATION (USC)ALASKA POWER AUTHORITY UPSTREAM HD 83-/9 82/4 3.7 POORLY GRADED SAND,(SP-8M' SUSITNA HYDROELECTRIC PROJECTCOFFERDAM WATANA DEVELOPMENT RIVER CHANNEL U/S COFFERDAM FDN.COMMENT::8~OF SAMPLE SAND GRADATION Il.llnUl'£MD~O,1 lJArC d nGVliC ...,,~.""N'"~'~.,AUG 1983 09 _.~,,...li --..-~ ". 1 J 1 ]I 1 '"1 1 ]1 -I ]J J 1 J GRADATION SIZE ANALYSIS u.S,Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer" 12 9 6 2 1 /2 1 3/4 1/2 3/B 4 10 29 40 60 BO 1 0140 200 210 100100I•I LEGEND I:":1:1\. WEIGHTED AVERAGE'90i90.~r\\ 1'\'---UPPER/LOWER RANGE 8080,\ ~/7070\ ~60 ...,-.<:~60 01\~..01 ;J<~ I~\..... 50 ;a .a::50 \\~.. ~... i: ...~40I c ...i:40 -1-- c,,......1\ec I OJ ~~30 ..~30 Q.....I'\~-~t\2020~ ~~..1010-~.--1"""'-t-- 0,001 001005010~1 0.5 0.1 0.05 0.01 0,0051000500 Grain Size in Millimeters I I GRAVEL SAND I FINES JBOULOERSCOBBLES[Coarse Fine Coarse Medium I Fine I Silt Shes ~hy Sh~~ ,LOCATION BORING NO.NO.OF SAMPLES %FRACTURE +3/4"CLASSIFICATION (Us C),.ALASKA POWER AUTHORITY ,DOWNSTREAM HD 83 27-3 37.4 WELL GRADED GRAVEL.(GW) SUSITNA HYDROELECTRIC PROJECTCOFFERDAM29,a 3/ WAT ANA DEVELOPMENT: RIVER CHANNEL COMMENT:0'OF SAMPLE DIS COFFERDAM FDN. GRAVEL GRADATION llJjnUHMl:lIC~1 DATe I ,/I;LlRE '""""JOIN'"Nrlm AUG 1983 010 ]1 -1 1 1 --1 J J 1 1 ~-l )1 -1 1 )1 GRADATION SIZE ANALYSIS U.S.Standard Sieve Openings In Inches,U.S.Standard Sieve Numbers Hydrometer 12 9 6 2 1 /2 1 3/4 1/3/B 4 10 20 40 60 801 Ot40 200 210 100 10 01111 I I I 1 'I rH'i'o.""'l......LEGEND I II I I I I I I I I I I r-.."I\..WEIGHTED AVERAGE 190 90 11 I I I I I I I II I "I\.1\---UPPER/WINER RANGE II I I I I I I I I I III I \1\I I I I I I II I I I I III I I 1 I I I I I I III I I I I I I I I I I I t I r I 80 8011111111 I 111111·11~1I11111 I tllllllill I II11I11 I I ~ 7011111 I I I I 111111-HfkHi-itHtHtt-l-l -H+-I I 170 ...60 ~1\"\I,,.~~60 ,,\,50 11 ;?'1\l\~~c;x ......~ 11 50 \"40 :::..I'"t'__.~., .~40 ,I'-.30 :II -.:1\',,-I'~,.....r--....."'~ :30 ......T -..l I I III I I I I I I I I I I I I :I 120 II I I I I I I I I I I I I I II I''"I I 1"'1o-סI.11 I I I I II I I I I I20111111I-I -\111111 I III I II III II.........~ 101111111 I -,1111111 IIIII1 111-111 "I~I 10 I+I-H I I I I IIIIIII III1II II+H+JH-1-I I I I 11-1111 I I I Io 1000 500 100 50 to !0.05 O.ot 0.005 n nnt O I BOULDERS COBBLES I GRAVEL I Coarse I FIne Coarse SAND Hedlum I Fine FINES Silt Shes I SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITYCLASSIFICATION(USC) (GW-GM) POORLY GRAOEO SANDY GRAVEL,40 I 28.0 NO.OF SAMPLESI %FRACTURE +3/4"" 3/,a 47 HD 83-24 BORING NO.LOCATION DOWNSTREAM COFFERDAM COMMENT:/38'OF SAMPLE WAT ANA DEVELOPMENT RIVER CHANNEL DIS COFFERDAM FDN. -------------------------+-1_SANDY G8AVEL GRADATION1l~{l1Jl'EM~iCO DArc-j _-FllivRE 'UII,,,A JO''''..,,,,u.,AUG 19831 D /I 1 I -]-1 1 1 ')I J J -1 -J I GRADATION SIZE ANALYSIS u.S.Standard SIeve OpenIngs In Inches U.S.Standard Sieve Numbers Hydrometer / 12 9 6 2 1 12 1 3/4 1/'3/8 4 10 29 40 60 801 0140200 270 100100~r-....I LEGE N 0t'-.... ....-....r"-"WEIGHTED AVERAGE 9090I'"i'...- --,.-UPPER/L.OWER RANGEr--... I'"1\ 80180I'..."..... "l\r---.r'--...7070 1"1 "1---"- r\.\60 ...1\,-J::co~60 1\,-f\....'"-;Jl~ ~..r\50 >,:Jl .Q::50 I'\L1\'"'\"L \'"i:.. 40"-l-i::40 I-...,c~'\.... ~"\...\30''"~...'"30 \1\I' ... ".....r ....2020 ...............'" I ........ ......""-1010-1"-."".....f"..,--1--I-- 0.001 001005010510.5 0.1 0.05 0.01 0.0051000500 Grain Size in Millimeters I 'it I GRAVEL SAND I FINES I Ii BOULDERS COBBLES I Couse Fine Coarse I MedIum Fine I Silt Shes ~lay S1z~~ LOCATION BORING NO,NO.OF SAMPLES %FRACTURE +3/4"CLASSIFICATION (Us C)ALASKA POWER AUTHORITY DOWNSTREAM HD 83-25 /I 8.6 POORLY GRADED GRAVELLY SAND. SUSITNA HYDROELECTRIC PROJECTCOFFERDAM26,28,30,31,(SP-SM) WATANA DEVELOPMENT47 RIVER CHANNEL DIS COFFERDAM FDNCOMMENT:38'OF SAMPLE GRAVELL Y SAND GRADATION ll.llftUl'£MDCO,\DAre f/(iVliE ,",liN.""'NT .IN'"''AUG 1983 012 1 1 I )1 -I ····1 I --I _..]-]J 1 GRADATION SIZE ANAL '{SIS u.S.Standard Steve Openings In Inches U.S.Standard Steve Numbers Hydrometer / 12 9 6 2 1PIZ 1 3/4 1/2 3/8 4 10 29 40 60 801 0140200 210 lOO1001--I'-I'-;::~~. LEGEND.........., r-"'"WEIGHTED AVERAGE 9090r-I....I::'"'"i'----UPPER/LDWER RANGE,.." K ~8080'"r".."'-, '"7070",, \1\60 ...,..: DO~60 1\1\-..'";JI-1\1\.. 50 ,.,;JI .0l:50 ~1\... "c...,,\r;:.. 40"...or 40 r\r\~.c. OJ... ~c .,\OJ OJ 30~30 "-...1\1\\I I\.\~2020 \.1'\.., I'.....~1010~........ 0 0.00\01010.5 0.1 0.05 0.01 0.0051000500\00 50 Grain Size tn MOl tmeters I I GRAVEL I SAND I FINES I I BOULDERS COBel ES I Coarse Fine I Coarse MedIum Ft ne I SIlt Shes ~lay Stze~ I LOCATION BORING NO.NO.OF SAMPLES %FRACTURE -I-3/411 CLASSIFICATION (US C)ALASKA POWER AUTHORITY DOWNSTREAM HD83-28,47 2 3.8 POORLY GRADED SAND. SUSITNA HYDROELECTRIC PROJECTCOFFEROAM(SP-SM)WATANA DEVELOPMENT RIVER CHANNEL DIS COFFERDAM FDN.1COMMENT:2'OF SAMPLE·. SAND GRADA liONI U.ll/Wl'EM13a::~1 DAre ~I 'U;VR£I ,.""......'N'.''''."'AUG 1983 .013 1----']'"~ I ~l 1 -~l 1 ,~.'1 ]'"1 -1 ] GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer< 12 9 6 2 1 /2 1 3/4 1/'3/8 4 10 ZO 40 60 BO 1 0140 ZOO Z70 100100•LEGE N0"W EIGHTEDAVER AGE 9090~-"""----UPPER/LOWER RANGE 1\8080, , \7070 60 ...,s:-'"~60 --1\IIgo ·-1-;II.. II \50 '"';II .0E50\.. II C.. ;::II ~40 c ...i::40 -.C II..r-tc II 30 II~""-II 30 I'",... - "2020I' I .......J"..,.1010--I- 0 0.001 010510.5 0.1 0.05 0.01 0.0051000500loa50 Grain Size In Millimeters .,, I FINES 1IIGRAVELSANDBOULDERSCOBBLESICOHseFineCoarseMediumFineISiltSizes~lay Slz~~Ii LOCATION BORING NO,NO.OF SAMPLES %FRACTURE +3/4"CLASSIFICATION (USC)ALASKA POWER AUTHORITY IJOWNSTREM HIJ 83-32 I 29.9 WELL GRADED GRAVEL,(GW) SUSITNA HYDROELECTRIC PROJECTPORTALWATANADEVELOPMENT-RIVER CHANNEL DIS PORTAL ·AREA I COMMENT:3'OF SAMPLE GRAVEL GRADATION 1l~{lIJHMtld:~I DArt'd FaiVRe ,"u,....".,"•.'"''AUG 1983 014 - \ j' I I 1 r I. r- ·1 3.2 RELICT CHANNEL 1 t 1 -]----1 -1 1 J )1 1 1 1 -.J GRADATION SIZE ANALYSIS U.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer "'eh... ~r--.. FINES ........ l'.... Silt Sizes Ie ... .f':"I. -r 1Fine I I I -.---, 60 8010014020027040 1 100 90 80 70 60 ~......... II:or: 50 >, ~.. II "___J4O i:... "., 30 ~., I I I I '" ,--I I I I I I I ,I I I I I I I .~Sj20 10 0_.001 ~lay slzeJ SAND Hedlum ~+i F?l~~~·---:.-.·'t;:Y.1S '.::::.,::"I I I I.I =="'I,'~tV~~~~ I Coarse I ~-I~I n~l-l l,,::;::,~:··:·:':'::l}§filli:::::~~1""'-.I ~":':::::':'::';::f:::.:·::-::·.:.::::i~:.l~:}J f' 1 i'l_1 I II I ristNI0It~Em[{{(}~·l NJIIII 1~1~ Fine ~~\~~r~.. 1 ~,r~~~ GRAVEL Coarse \T\1~~~rJ0~:'L IIITTIf=l=. 3 211/213/41/23/8 4 10 20 Ir 6 COBBLES -,-12 9 LEGEND I'-...."",:.::::..;•..;-..., WEIGHTED AVERAGE,·::.{!;.tt t'4-.l-.1 I - - -UPPER/LDWER RANGE I......::;I I'~I~~- • •ACRES STATISTICAL,,I I I I I I I I II I I I I I I I AVERAGE ." - e -ACRES UPPER /TtN..... o.LOWER RANGE .III -I'+-I I 1000 500 100 50 10 5 1 .0.5 0.1 0.05 0.01 0.005 n Grain Size In Millimeters r 80ULDERS 100 90 80 70 ~60 <7l-II:or: :;50.. 1/ "i:40 ..... "II... :30 20 10 BORING NO.NO,OF SAMPLES I FEET OF SAMPLE CLASSIFICAT ION (USC)ALASKA POWER AUTHORITY WW-3 8 I 13 SILTY SAND,(SM 1 SUSITNA HYDROELECTRIC PROJECT WAT Al\IA DEVELOPMENT RELICT CHANNEL. I I I t I UNIT M GRADATION RANGE SILTY SAND t I I I ·"l.ttUJH~~tl~O I DArE I FlGVIIC......_."",.,.'_'u.,AUG 1983 0/6 1 1 1 J ---I _."~-J 1 ,.-~1 1 1 -I 1 ---1 1 GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Stondard Sieve Numbers Hydrometer 12 9 6 3 2 11/2 1 3/4 1/23/8 4 10 20 40 60 80100140200 270 100100,I I---['•I ,I'LEGENDr--... "'""-"WEIGHTED AVERAGE 90-, 90 " '"- - -UPPER/LOWER RANGE ~"I"-8080 I"'i"o.'""- I'---"'\.......7070r--....'"I'"~..",~, 60 ... .J::...~60 0;...i"r-..";lO-'"'"....lU 1\50 :;J< J:>:3 50 - I'"I-"IIc:.. "-II "40 ....c:..;:40 ...""~. II... ~c: OJ ":...30 OJu...t 30<>. [, I' 2020r--.....-----1010- - 0 0.001 010510.5 0.1 0.05 0.01 0.0051000SOD10050 Grain Sile In Millimeters. I I GRAVEL I SAND I FINES IBOULDERSCOBBLESICOHseIFineICoarseMediumFineISiltShes~lay SIz~~ ------ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICATION (USC)ALASKA POWER AUTHORITY HD83-1.3,4,6,9 91 223 SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RELICT CHANNEL UNIT G'GRADATION RANGE SIL TV GRAVELL V SAND IIJjtUJHMtlCO,1 OAre'FI~UR( ,.,,'N'.....,"N'.",AUG 1983 o 17 ··°1 "1 1 1 1 ]I 1 ·~··l 1 )J 1 1 1 GRADATION SIZE ANALYSIS u.S.Standard Sieve Openlngs In Inches U.S.Standard Sleve Numbers Hydrometer, 12 9 6 2 1 12 1 3/4 11 3/B 4 10 29 40 60 801 0140 200 210 100100......1'",I I ,I'- ""r0-t....--CLAY 9090 ..........r-- r'1't-8080--.r--- ...7070...... SANOY SILT ~ "...,60 .r. '"~60 "-..'"-;II-,.,.. 50:II ..:lE50I- OJ<::I--OJ 40 ..."....i:40 f-1-- '". OJ.. ~<::.. 30 OJt30... a. 2020 - 10 10 a 0.001 0 10 5 1 0.5 0.1 0.05 0.01 0.005100050010050 Grain Slze in Millimeters I I GRAVEL I SAND I FINES IBOULDERSCOBBLESICoarseF1neCoarseMediumFineISiltShespayShe~ MATERIALS .NO.OF SAMPLES FEET OF SAMPLE %MAT'L IN SECTION ALASKA POWER AUTHORITY 6 50SANOYSILT4 SUSITNA HYDROELECTRIC PAOJEC.T CLAY 4 6 50 WATANA DEVELOPMENT RELICT CHANNELTOTAL S 8 /2 /00 UNIT J GRADATION SUMMARY .IlMl1Jl·E~~I'lCO,I DM£I "'Lllle ,"",••.."N'.,.ru.'AUG 1983 DIS -j -1 1 _..-.-]1 1 1 ·1 )J -I -.--1 GRADATION SIZE ANALYSIS u.S.Standard Sieve Openlng5 In Inche5 U.S.Standard Sieve Number5 Hydrometer, 1Z 9 6 Z 1 P/2 1 3/4 1/'3/6 4 10 20 40 60 601 0140200 270 100100r--..r-...........LEGEND,,"f"r--..r---WEIGHTED AVERAGE 9090I...~r-..r-....'....- - -UPPER/LDWER RANGE-........."'r-....... """'-...8080I""-....i--....",,---......-............................7070"'-,........................ ....................,60 ,I:~60 """" -.,.r-.."~0\ :x-;;---/--~"........ .......>,:x 50 .QE50I............L..c:.......i'::..c:b _40i:40 1-....c:..... ~c:.. 30 ..~0-..30....- 2020- 10 10 0 0.001 0 500 100 50 10 5 1 0.5 0.1 0.05 0.01 0.0051000GrainSizeinMillimeters r I- GRAVEL SAND I FINES IBOULDERSCOBBLESCoarseFineCoarseMedIumIFInerSiltShul:1ay Sh~~ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICATION (USC)ALASKA POWER AUTHORITY H083-1 4 6 SANOY SILT,(S"')SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RELICT CHANNEL UNIT J GRADATION RANGE SANDY SILT 1l~IUJH:t."lI'3CO,I OAr£FlliURe ,.."••"",.r .,.,~.,AllG /983 019 1 J "'1 1 1 J 1 -]1 1 1 )i '1 ,i J GRADATION SIZE ANALYSIS u.S.Standard steve Open1ngs In Inches U.S.Standard S1eve Numbers Hydrometer, 12 9 6 ~2 1 /2 ,3/4 1/2 3/8 4 10 20 40 60 801 0140 ZOO 270 100100I""--LEGEND--- WEIGHTED AVERAGE 9090 - - -UPPER/LOWER RANGE 8080 7070 60 ...\.s:;~60 -co-..co -1-;ll.. 50 >,;ll -.<>};50 L.. <:L i:.. 40 <: 1--i:40 --f---.. <:..... I---~<:.. 30 II~""..30... - 2020- 1010 0 0,00,01005010510.5 0.1 0.05 0.01 O.OOS1000500 Grain Size In M1llimeters I I GRAVEL SAND I FINES IBOULDERSCOBBLESICoarseFineCoarseIMediumIFineISiltShes~lay Stze~ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFI CAT ION (USC)ALASKA POWER AUTHORITY CLAY,(CL)HD8~-1 4 6 SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RELICT CHANNEL UNIT J GRADATION RANGE LEAN CLAY Il.tlUJH:l."1tlC~I [we FI.VRC '""'~....,.,"~,,,.,AUG 1983 D20 1 ]1 1 ]I ~]1 1 1 1 '.1 1 1 GRADATION SIZE ANAL VSIS u.S.Standard Sieve Openings In Inches U.S.Standard Steve Numbers Hydrometer \ 2 g 6 3 2 11/21 314 1/23/8 4 10 20 40 60 80100140200 210 100100 "'""~••.., 90 'r---."I'..90""f'...... '\.......... 8080I\.....r-..""- 70 '\..~70'\~. 1\"60 .. ~60 JC:...r-.J SILTY SAND -tJl 1\..-;a..,\., '"':II 50:::50 ..<> SANDY GRAVEL ~"-L..L .-~-<<:;.. .........,1""--'"40 ... i:40 -..-.r-..-.'... ..................~.c....c "-~.. ~30 "-30 ..a....I'i'i"o1'0.. I"-2020.......!"-- 10-1"-t-ID10 0 0.001 01005010510.5 0.1 0.05 0.01 0.0051000500GratnShetnMllltmeters I I GRAVEL I SAND FINES IBOULDERSCOBBLESICoarseFineICoarseMediumIFineSiltSizesFlaySh~~ MAT£RlAL ~NO.OF SAMPLES FEET OF SAMPLE %MAT'L IN SECTION ALASKA POWER AUTHORITY WELL GRADED SANDY GRAVEL /0 26 26.3-.•.SUSITNA HYDROELECTRIC PROJECT WELL GRADED SILTY SAND 35 73 73.7 WATANA DEVELOPMENT RELICT CHANNEL TOTALS 45 99 100 UNIT ElF GRADA liON SUMMARY IJ.lHILJl·lMl'!4:0,I DAfC I ",Gvlle,,.",....,"~,...r....AUG 1983 021 1 1 1 1 r-~-)].1 1 ~~-]~]1 1 }1 ) GRADATION SIZE ANALYSIS U.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer LEGEND 1\1 l2 9 1 6 r~~if?f::;;~~;~~...3/4 11,23/8 4 10 20 40 60 80100140200 ~~O...,I_I I II i I I I I I i 1100 J.J 1 ')U~i~n\tJm~!~._+~.~II I I I I H I 190~1 '•••:.;.:.",;;:.:.'.;.:.:'.:.:::}~f.;~~'"--I--f--.1-.'j-..........I~-W-•I 1',\'il @ll\\~:t!.Ni~Wf :i:Yti:~:~~J!i!p.::~...."l-tl ~.-[.:J -1-1 I I 180T~l \.i"'fi[':'::'';':.:''':~.,;.:.:::::.;:.....;'..:....~rei .'.,!;::~!~f;i :~~;~;;;:.·~;:~~;t~~~~~:.~;:.~1--I .\."'''''',·''''ii!')~''*"'',''...~.--~_.1. 1'-'-1=.1'1 70 .--:·----·-~I-I-rW-i-f--1---- --i-._-t-t"I..l-l-i-.-I 100 90 80 70 ~60'· '"-'":Jl E 50.. '"c i:40....r::..u ~30 20 10 NO.OF SAMPLES I FEET OF SAMPLE CLASSIFICAT ION (USC)" Silt Shes ALASKA POWER AUTHORITY FineMediumFine C.::';'tEl CoarseCOBBLESBOULDERS BOAING NO. SUSITNA HYDROELECTRIC PROJECTSANDYGRAVELfSP/GM)10 I 26HlJ8J-2.4.9.49 52.a ww·"~WATANA DEVELOPMENT RELICT CHANNEL UNIT ElF GRADATION RANGE SANDY GRAVEL ·I I I I f-/l.t-rllll-.(-t\tJ-tlc-";oCD~ri:l FlfiVIll ~~~~J\I ,,..'(\0'";.022 l J~--~l ]1 '~J -1 1 ]J 1 I )1 1 GRADATION SIZE ANALYSIS U.S.Standard Sieve Openings In Inches U.S.Standard steve NUmbers Hydrometer r-:;;:1 10 I I I 120 I-+-=: _.~_._._-J---I--!~·,::·:·:::3::_:::n4J·~·:·:·:·::~.:.i:t:::::f::X:::·:tit:\bJ- ...1 H-I-+I"-}"~- f::tj "-. 3 2 11/213/41/23/8 4 10 20 40 60 80100140200210~".'_..,''''''''''''','""."..,,,.,,,,.•.,".,·,·n·.•..•.-".•.",..,.""".w''''''IH•.l I I •I,,'_1~·EE=f,.~~:: ~~!{..~:----tf=t=Uj '{~J~Y~:~.-·'-~-~H-1-H~.J:::J:;:~:.~.~::·~J:/t~~:?~;\.r I I I I I I I I I I"I I 1--1=1-=1 11+11 I I "I ,1- 6129 LEGEND f\ ___1-+--·__· _ ~r.- -- -"~t}!:m:!~;~?j\/::~~~:;.;~;I'a~ WEIGHTED AVERAGE j=f='-f--..;-~~~LSi.;~i~.ii:\~~:;{\\~;~r--.... - - -UPPER/LOWER RANGE -------J---1---i.....,J••}•••:.!.!.::."100..~1-"".~..:.:....:.I.....____ • •ACRES STATISTICAL -I--~----~----------I ..-........\:~;,.;~*~...... AVERAGE ..1 1_'".-.;;:·::i:1 l'-..~ -.-ACRES UPPER /J I .."""a LOWER RANGE L.---------1--------I ....""Ifill I I I I 10 1000 500 100 50 lU 5 1 0.5 0.1 0.05 0.01 0.005 0.001 Grain Size in Millimeters I I F triMEL SAItO FlIlES ~BOULDERS .COBBLES •'".C04ru fine MedIum Fine Silt Sizes thy Sh! 100 90 80, 70 ~60" t»-II :JI }:50 I-..c i:40.. C III ]30 20 10 l- I SUSITNA HYDROELECTRIC PROJECT ALASKA POWER AUTHORITYCLASSIFICATION(USC) _SILTY $AND,{SAI)73 FEET OF SAMPLE 35 NO.OF SAMPLESBORINGNO. 9,50 -528WW-3 .H083-1.2,4,5,8 WAT ANA DEVELOPMENT RELICT CHANNEL UNIT ElF GRADATION RANGE __-..,.SIL TV SAND I I II·I/I.tnlJl'IMtlCO --;Mrc-r "'vU '.V,"'"10'*'•••,....AUG 19831 6-23 ~1 --]~l 1 --~]~l -1 1 --~l -1 1 1 1 1 J GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard SIeve Numbers Hydrometer / 12 g 6 2 1 I'Z 1 3/4 1/3/8 4 10 20 40 60 80 1 0140 200 270 100100r---.•i'"- "".........'"90901\'"1\r"-8080\I'-...... !\."j'--..7070'"""'"I'.. ""60 ...:.... '"~60 '" ,-i"!SILTY SAND ..Ch :;II-'">. .. 50:>0 I'.~J;50 "I'..f'L..<:L ~'\i:.. 40<: ....i:40 ".cr--.......... ~c SANDY GRAVEL 0:>-I'-..... 30 ...~30 ...,... I'-..'"r--....'"I'-2020'"r.....""I":.......r---1010--- 0 1 0.001 0 10 5 1 0.5 0.1 0.05 0.01 0.005100050010050 Grain Size in Hlllimeters I I GRAVEL I SAND I FINES IBOULDERSCOBBLESICoarseFIneCoarseMedIumFineISiltSizes~1ay SIz~~ MATERIAL NO.OF SAMPLES FE'ET OF SAMPLE %MAT'L IN SECTION "ALASKA POWER AUTHORITY WELL GRADED SANOY GRAVEL 5 /I /8.7 SUSITNA HYDROELECTRIC PROJECT WELL GRADED SILTY SAND /7 48 8/.3 WATANA DEVELOPMENT RELICT CHANNEL TO'TALS 22 59 /00 UNIT I GRADATION SUMMARY Il.tnUl·£:l."lI:lC~I D~rc I '/liVRe ,...'w ......,".'u.'AUG 1983 D24 -J 1 ----1 I )]1 1 1 -I 1 -~]1 ) GRADATION SIZE ANALYSIS u.S.St~ndard Sieve Openings In Inches U.S.Stand~rd Sieve Numbers Hydrometer, lZ 9 6 2 1 /2 1 3/4 1/'3/8 4 10 29 40 60 80 1 0140 200 210 100100r...",.LEGEND"'\"r-. WEIGHTED AVERAGE 9090"---UPPER/LOWER RANGE r\l\I\.8080\[\\ 70 I\.70~"l' \"'-I'......,60 ...s:~60 00\1'.,...............00 ;II&I ,i'............50 >,;1Il ,Q::;50 1\"'r--....".... '".. "'"L: .. 0:;-~40i:40 --1--I--1-...1\~.c:..... 'C'".......... "~.30 ..~30 Do "-~"I'-..~'"'r-,-"-i'.""'......2020r-...........r---......r......... I·r--.....1010-1--1-_ a 0.001 01005010510.5 0.1 0.05·0.01 0.0051000500 Grain Size in Millimeters I I GRAVEL SAND I FINES I80ULDERSCOBBLESICoarseFineCo~rse MedIum ,Fine I SOt Shes ~lay Siz~~ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICATION (USC)ALASKA POWER AUTHORITY '1-HD83-5,6,52 5 /I WELL GRADED SANDY GRAVEL,rGW-OM} SUSITNA HYDROELECTRIC PROJECT WAT ANA DEVELOPMENT RELICT CHANNEL UNIT I GRADATION RANGE SANDY GRAVEL ./l.taw-£~'lltlC~I DAre .'(j2~....,••..".r ...,~.,AUG 1983 J 1 1 -1 1 1 -1 ----1 ]]1 -1 1 J J 1 GRADATION SIZE ANALYSIS u.S.Stand~rd Sieve Openings In Inches U.S.Standard Sieve Numbers N)'drama ter 12 9 6 3 2 11/21 3/4 1/23/8 4 10 20 40 60 80100140 200 270 100100i'l-...~".L.:rl I I I LEGENDr-.... ~I-~~'-1-.WEIGHTED AVERAGE 9090I~1""-"'---UPPER/LOWER RANGEr.....-"';"1\8080"-,....1'-0---"-I'I'-.....t'--t.....7070------1-""'-...I'r-..--I-I.....1-~'\60 ..~.z;~60-I--1--.;;;;;DOi'..-'"DO ~;x-1--1---- "I'.'" " ~50 ....;x .a£50 -1---f-"~1\.. III..C-"\....'""lo.C 40i:40 -----I--1\-..."cI''"...--I---~C I---I--1------1\'"~30 ..t "-3D --------""-... I\.."- I_r,t--I"r-....."2020-............i'.!-...i'-----.........--........""'---r---...-1010--r------1-----.I"~---1-....--....---I-I--I--~ 0,001 00 100 50 10 5 1 0.5 0.1 0.05 0.01 0.0051000500 Grain She in Millimeters I GRAVEL I SAND FlIlES IeOULDERSCOe~LES I COdrse I Fine I Coarse Medium Fine Silt Sizes ~1ay She~ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICATION (USC).ALASKA POWER AUTHORITY WELL GRADED SILTY SAND,(SM)HD83-1,5,6,8,52 17 48 SUSITNA HYDROELECTRIC PROJECT WAT ANA DEVELOPMENT RELICT CHANNEL UNIT I GRADATION RANGE SILTY SAND lIMUJl'I~-llIlCO/1 {)Arc F/fiVlll Jw,,'~A ...,.,'''/wOl AUG 1983 026 1 I ~-]J 1 I 1 ~--~]]J GRADATION SIZE ANALYSIS u.S.St~nd4rd Sieve Openings In Inches U.5.St~nd~rd Sieve Numbers Hydrometer LEGEND '\l I1I111 I ~t~1J~,;:~11"1. I".I111 I I I I ~~~~~i:;:i~iF.l\'Sol~Iiik'f,~~~ ~~~1-I-f~--H+Ht1~1HI1111 I I I I I 100 90 80 70 60 ~...-OJ:a 50 :;.. OJc:-40 u....c:.. 30 e.. D. 3 2 11/2 1 3/4 1/2 3/8 4 10 20 40 60 80100140200 2706129 100 90 80 70 ~60... OJ:a E 50.. OJ 0: ~40.... 0:.. u ~30 20 10 I I GRAVEL I SAND~BOULDERS COBBLES COHse I Fine Coarse I Medium I t-J I I I I I II III I I I I - -..----_.01 0.005 0.0~,0 j FINES ...Ei~Y_SI~~]Fine Silt Sizes BORING NO.NO.OF SAMPLES I FEET OF SAMPLE CLASSIFICATION (USC)ALASKA POWER AUTHORITY HD83-4.52.5.J a WIY-3 8 I 27 SILTY SAND,(SMJ SUSITNA HYDROELECTRIC PROJECT WAT ANA DEVELOPMENT RELICT CHANNEL UNIT C GRADATION RANGE SILTY SAND I I I ,IIlMUJH~·IHICO I DArc I"nliVRCIU"'~''~'.,.,.'u"AUG 1983 027 J I J I -)-1 J----l I 1 1 1 1 1 GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer ~12 9 6 3 2 11/21 3/4 1/23/8 4 10 20 40 60 80100 140 200 270 100100.[I •,. "'-~"""~...........9090 "r---", "r"'--"8080"\"r-... "7070 "t- I'60 ..I'..,z:~60 .,.'\1\&i0> :a.... "\'"50 >,:II oJ)};50 '\~SILTY SAND L.. C........"i\40 ...c i:40 ~.-..\cf'.........I ec \..SANDY GRAVEL ""'--"30 oJu"<L~30 -..."'",f\ ,,~.._--~- 1""'"2020......1"-.".........""-1010..........1-01-0 0 0.001 01005010510.5 D.1 0.05 0.01 0.0051000SOD Grain Size in Millimeters I I GRAVEL SAND I FINES IBOULDERSCOBBLESICoarseIFineCoarseMediumFineISiltShes~lay Sh~~ MATER IALS NO.OF SAMPLES FEET OF SAMPLE %MAT'L IN SECTION ALASKA POWER AUTHORITY WELL GRADED SANOY GRAVEL 6 _10 32.3 SUSITNA HYDROELECTRIC PROJECT WELL GRADED SILTY SA NO 10 21 67.7 WAT ANA DEVELOPMENT RELICT CHANNEL TO TAL S 16 3/100 UNIT H GRADA TlqN SUMMARY IlMUJH:L-1lI3~Ofl DATe I :FUiVRe J."'~'..,.•r .'~JII.f AUG 1983 028 J 1 J I .J J 1 ~'1 '1 ],I D I 1 .GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer, 12 9 6 2 1 ~/2 1 3/4 1/3/B 4 10 20 40 60 BO 1 0140 200 270 100100......1'-..............•LEGEND \.......I\.WEIGHTED AVERAGE 9090....1\"- - -UPPER/LDWER RANGEI',I'\..\80801\"r\,I' 7070 " I'f\. r\1\60 .....",~60--Do \1\~........ :s--..\1\'~50 ,.,:a .a:;50 '\..-\.. ".. ""..... 40 ....c 1\--I-i:40 -...."-.c"......I,~c '".. r\30 ..t 30 a- I'".......1'0""- ........t"-r--.,........2020..........................".......~I'-........'"1010.."~-l- 0.00\001005010510.5 0.1 0.05 0.0\0.0051000500 Grafn She fn tl111inleters I I GRAVEL SAND I FINES IBOULDERSCOBBLESICoarseFfneCoarseMediumIFfneISfltShes~lay Sll~~ :BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICAT ION (USC)ALASKA POWER AUTHORITY WELL GRAOElJ SANDY GRAVEL,(GW-GM)HD83-1,3,5 6 10 SUSITNA HYDROELECTRIC PROJECT W AT ANA DEVELOPMENT I RELICT CHANNEL UNIT H GRADATION RANGE ! SANDY GRAVEL Il,ljIlUl·£~.fJI'l£O,I DATC FNil/flC """NA -"".r ..N'.....AUG 1983 029, '1 -"1 1 1 ······f 1 '""1 1 1 I J '1 ''''"" GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer, 1Z 9 6 Z 1 ~IZ 1 3/4 11 3/8 4 10 2Q 40 60 80 1 0140 200 270 100100.....'"......1'..I I f\.1'\90901\\ ,,~8080" 70 ~70 i'- r-.....60 .., SILTY SAND ~~60 -.,.\......-............,. :--..~....... 50 ,.,;a -.Q};50 ~--~.- \r--..........ui'-..c... ...............i:il 40 c I-.....i:40 ...r---...,ci\.... ~C II ~I'30 ..~30 SANDY GRAVEL -Do..." 20 "'-20~ 10 r--I-....10-r-- 0 0.001 0 100 50 10 5 1 0.5 0.1 0.05 0.01 0.0051000500 Grain Size In Millimeters I I GRAVEL SAND FINES ICOBBLES,~hy SIz~~BOULDERS I COHSt Fine Coarse MedIum I Fine Sl1t Sizes I MATERIAL NO.OF SAMPLES FEET OF SAMPLE %MAT'L IN SECTION ALASKA POWER AUTHORITY 7 70POORLYGRADEDSANDYGRAVEL7 SUSITNA HYDROELECTRIC PROJECT SILTY SANDY GRAVEL 2 3 30 WAT ANA DEVELOPMENT RELICT CHANNEL TO TA L S 9 10 fOO UNIT K GRADATION SUMMARY IlMlUHMI3d:~I DAre '/(illll( Iw .......".r .,.'u.,AUG-1983 D31 J J I -1 -;))-}-1 1 1 1.1 GRADATION SIZE ANALYSIS u.S.Standard Sieve Openings In Inches U.S.StAndard Sfeve Numbers Hydrometer, 12 9 6 2 1 n/2 1 3/4 1/'3/8 4 10 20 40 60 801 0140200 270 100100I~'"",I 1\r\90901\"-\ i\~8080 \ \7070\" \~,60 ...c~60 -.-'"\..'"~;0:.. " ~, 50 >,;a Ll1:50 ,~..... L.C.. 1\~i:"40i:40 1---I--..1\I'"-.c:.... ~c r\-.....--..I,"-3D ..t 30 ......., ~............-i ~"'-....:--'-2020~,r---.. --f-I'-....-~I-or-.~1010....100 -I--..- -.r-'-.... 0.001 00 100 50 10 5 I 0.5 0.1 0.05 0.01 0.0051000500 GrAfn Sfze fn Millfmeters I I GRAVEL SAND I FINES 1BOULDERSCOBBLESrCoarseFineCOArseHedlum1Fine1SiltShes~lay S1ze~ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICAT ION (USC)ALASKA POWER AUTHORITY POORLY GRADED SANDY GRAVEL (8P-8M)HD83-1 7 7 SUSITNA HYDROELECTRIC PROJECT.W AT ANA DEVELOPMENT RELICT CHANNEL... UNIT K GRADATION RANGE. SANDY GRAVEL Il.t[l)l'EM~4:~l OAr£FIlHlR~ '....'N •..,.•('(N'"''AUG 1983 D3 J -1---])1 -1 1 1 J -)]1 ----)I 1 ) GRADATION SIZE ANALYSIS 1 U.S.Standard SIeve OpenIngs In Inches U.S.Standard Sieve Numbers Hydrometer/ 12 9 6 2 1 12 1 3/4 1/3/8 4 10 20 40 60 BO 1 0140 200 270 100100""'r-I LEGEND r\WEIGHTED AVERAGE 9090[\---UPPER/LOWER RANGE ~8080'"1'0.. I"-7070 'I"-.. '-60 oJ,.r.~60 -Do.........-r-.....Do :a-.. -.........""50 ,.,;K .0;:50 1"'-I'--r---.L.. '"L ~i::.. 40 0::...i:40 -1-1------"'1"---.c:. '"... ~0::.. 30 ...~a...30a. - 2020 1010- o I 0.001 010510.5 0.1 0.05 0.01 0.005100050010050 Grain Size In MIllimeters I I GRAVEL SAND I FINES IBOULDERSCOBBLESICoarseFlneCoarseMedIumIFIneISl1tSizes~lay Slze~. BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICAT ION (USC)AU\SKA POWER AUTHORITY SILTY SANOY GRAVEL,(GM)H083-J 2 3 SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RELICT CHANNEL UNIT K GRADATION RANGE SANDY GRAVEL 11.t1UJ1·EMtlCO,I DATe "cwle Ju,,'_'...,.r .,.,~.,AUG 1983 D33 'J 1 ]1 1 1 I C-]1 1 1 1 I 1 GRADATION SIZE ANALYSIS U.S.Standard SIeve OpenIngs In Inches U.S.Standard Sieve Numbers Hydrometer I 0.00\0 ~1ay Sll~~ FINES 0.01 0.005 Silt Shes 0.05 1-f 0.1 Fine I SAND I Coarse I MedIum I 5 1 0.5 GraIn Size In Hl11imeters 10 ~J--'..1I1I I l~l1JJl{{{!!itJ/W?i:?W%fmIl:\~f;Wll'i': "'"'Illl N..I./-I I II II'f4TIfllih:n([\};?{j;{@n~[EEt "h.. ~n~I~.':::.:::·:·:-::::::·:r::::f:'l0F~~;rlll··:t:.·;·~:"I I .I I I I ~'·:;i;l:,ti:~:1;/I!{!l1.::::1;1:;::!!I::!:!!;:fi!:f!.\:!:::;;;;[:~E}:}t I FIne GRAVEL ~I I 50 ~~Jl~BtJITB%l?Bt.~liITTl'f:('I ' 3 2 11/21 3/4 1/23/8 4 10 20 40 60 80100140200 210 I Coarse I 100 .- COBBLES 12 9 6 111I1 I I I I IIIII--l-I-I I l++-I-I-~~l~~1#1 f"Nt I'~ o 1000 500· I BOULDERS LE <lEN 0 -,..~----.-...." ----WEIGHTED AVERAGE ~I.I...I__I 201 ---UPPER/LOWER RANGE t--..._•• _20 • •ACRES STATISTICAL 101 AVERAGE 110 -.-ACRES UPPER /I LOWER RANGE 100 90 80 70 ~60 0>-'"=- };50....c i:40... C IIIu :30 BORING NO. W»'-3 NO.OF SAMPLES 4 FEET OF SAMPLE 4 CLASSIFICATION (USC) SANDY SILT,(ML) ALASKA POWER AUTHORITY SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RELICT CHANNEL UNIT 0'GRADATION RANGE SANDY SILT I I I ~I/l!lIUJl'£~-Ilorlll {)Arc I F/fiIJRCJ...'.O ...,.~.J.::'.J AUG 1983 0 34 -~-1 --1 1 ---1 ....}---1 1 ---1 ]]-]1 1 1 ._) GRADATION SIZE ANALYSIS U.S.Standard Sieve Openings In Inches U.S.Standard Sieve Numbers Hydrometer - 0.001 00.0050.01 FINES Sl1t Sizes ALASKA POWER AUTHORITY JJ:1- 0.050.1 Fine 100 90 ~80 11 I I I I I I I"~7.·..."'-L·~~."I.:"IIr.I ; 70 Ir 1~::::l~;;~~~~:.!~:~l;~~~~~.~~~;~:O/\1[ljjjjj 1 60-l-l-L-l~dd/::::.'··.··. -150-l-I-U I I I I 1·....,.,.""""'·."X.;.:O,'''".;·";.,.:.•,,.·'..'..~1 I I I I I SAND CLASSIFICAT ION (USC) MedIum 1 0.5 Grain Size In Millimeters f'-.... 510 Fine GRAVEL Coarse 50 3 "I 100 6 NO.OF SAMPLES t FEET OF SAMPLE COBBLES 1Z 9 500 • ..;,o;:I'::I::"J""¥":'::I:~'~. II I I I I II..I 1/I I I I I ~>E.•~""",~'.~,~.:~.~.~:::.:.:..:.:."·H-H-J-t-t-~__..........:::....,"':\::::".;,',"::::::"'.I';:I::j, 1--~::!f\t::~;;~[{(l(1 ~~!:~:~~~ ~k~:~:~":'f{~;~:f~:;~i ~40 ~ ~'::''''''1Iio'.:.::.::r~.c ..............;;.;-::::~~~:[I r;:;'.:~~.~~~.'.~ I I I I I,1--I~-f'.:if ;:"',:.:i]j,~30 £.Illl~8L;;;;;E±;;;G;;;;;E;;±N::;:;D==:±t±±l::±:±11--I.r'o'K~:~~:f~~"""" ........':i;P.ii.i::;:••;•.:;.;:.----.WEIGHTED AVERAGE i'..~~!!!:~~~:~;20 ---UPPER/LOWER RANGE ---..........."'if~:~ • •ACRES STATISTICAL -........";'10 AVERAGE I'llI':-- -.-ACRES UPPER I __~__ LOWER RANGEo 1000 BOUL DERS BORING NO. 100 90 80 70 ~60 '"-'";II: E 50....c i'.:40...c '"u :30 20 10 HD83-4-6J 49 9 I 17 SILTY CLAY,(ML/CL)SUSITNA HYDROELECTRIC PROJECT 'Ilil/IIE 035 WATANA DEVELOPMENT RELICT CHANNEL UNIT G GRADATION RANGE SILTY CLAY /j WW-3 I I I I !1I.GI1IJl-E:l.~tl C0 '&llIt.,..JOJ"r yilt""'''' 1 1 ._)1 }J ··1 <1 1 1 I 1 I GRADATION SIZE ANALYSIS u.S.Standard SIeve OpenIngs In Inches U.S.Standard SIeve Numbers Hydrometer, 12 9 6 2 1112 1 3/4 II 3/8 4 10 20 40 60 801 0140 200 270 100100.r-....----I •LEGENDr-.. I..... ""r-." I""r---,......."WEIGHTED AVERAGE 9090..............r--....,- - -UPPER!LDWER RANGEr-.... I'..r"..~8080~."\ r---.\70701'1 , f',. I'1":'\1\60 .... .."~60 _._--00 ~\,-""'"-1--=--"-"'\.~50 >-,:JL .0:;;50 "\.....c.. '\i::.. 40"i:40 -1-1-1--1-..'"<:1\..... e<: '"< .. f'...30 ..t 30 <>-... 'I'"r"...2020-I I'I -1"".. 1010 --- 0 0.001 01005010510.5 0.1 0.05 0.01 0.0051000500 GraIn Size In MIllImeters I I GRAVEL SAND I FINES IBOULDERSCOBBLESICoarseFIneCoarseIMedIumIFIneIStltSizes~lay Sh~~ BORING NO.NO.OF SAMPLES FEET OF SAMPLE CLASSIFICAT ION (USC)ALASKA POWER AUTHORITY WELL GRADED SILTY SAND,ISM/8M-$e}H083-2,5,6 18 23 SUSITNA HYDROELECTRIC PROJECT WAT ANA DEVELOPMENT RELICT CHANNEL, UNIT E GRADATION RANGE 1 SIL TV SANDI Il.MIlJl'E~~tlCO,1 PArc F/(iIlRC ,.",••"",.,.,••".,AUG 1983 036 ~]-]1 ~)1 J I ) (INCLUDES ALL TESTS 1978 -1982) SUSITNA HYDROELECTRIC PROJECT WATANA DEVELOPMENT RELICT CHANNEL_, MATERIALS ABOVE UNIT E PLASTICITY SUMMARY 9DMIU~.flB,;l.I'~a;:iWl--DAT'----:'T~.F~ounE SUSITNA JO ..,Vl:"';f J AUG 19831 0'37 40 I j j I iIi I ,,1ft ,I I I I I I I -0 UNIT C (N=4) YJ UNIT 0 (N::5) 50 t+++X UNIT 0'(N=2)+-I I I I iii i ;~ill I I i ~i i t @ UNITM (N=5)*1983 DATA UNIT C (N=I) UNIT M (N=2) 60 f f t ,f t f iff i If'If 1 .t ,f ,i f i it,t iii 'i 1 -J itt fiT , 1 f if't 'T f •f i i 1 f f ;f 1 if'1 l'f r i -I t i '4 f ,1 f T1 ~u ~a.. ~az TEST PERFORMED ON MATERIAL PASSING NO.40 SIEVE IN ACCORDANCE WITH ASTM D423-66(1972)AND D424-59(1971) ".-~I OJ 1 J 1 "I !J SUSITNA HYDROELECTRIC PROJECT .. WATANA DEVELOPMENT 'RELICT CHANNEL .RANGE OF PLASTICITYUNITS'ElF --.. 1-1-=HIi-RU...,....,.---.EOO--::"'-=-=*!G@I·"lfATEITFIGURE susn'.JOINT VENTURE AUG 19831 038 5040 LIQUID LIMIT 302010 60 Iff f f 1 f f ttl 1 j I i 1 .j Iff I \I j r r 1 j j t 1 "r 11 t 11 t T'f F tIt t t 1I t ~ ~ 50 40 II I I I j I I ~u ~ Q.. 6 SAMPLES NP. TEST PERFORMED ON MATERIAL PASSING NO.40 SIEVE IN ACCORDANCE WITH ASTM 0423-66(1972)AND 0424 -59 (1971) (INCLUDES ALL TESTS 1978-1982) -----=:)--=-:]----J _J 1 1 1 1 1 1 ---J -l~--l -1 1 ) SUSITNA HYDROELECTRIC PROJECT WAT ANA DEVELOPMENT RELICT CHANNEL MA TERIALS BELOW UNIT ElF PLASTICITY SUMMARY lHoillftVHE/f.l~*(r;iV,OATE F1GURe-~---'~ ,uSITNA JalNT VENT<!RE AUG 1983 D 39 10 50 20 I-+-~";'-++++++- 60 i r 'l I t !{t t 1 t f 4 f t if·t fV t i \,itt 'f f I I 1 t i f \if'i \T 'i , [:) I:) Z ~30 H-\-++,·-i-4++-I-++ [j i= 5 0.. ~~:N(~~)G"HI:r'..d!JJ 1·;-'"";"[r r T+++~i+±++tih"il~TT+t+i+++++ TEST PERFORMED ON MATERIAL PASSING NO.40 SIEVE IN ACCORDANCE WITH ASTM 0423 -66 (1972)AND 0424 -59 (1971) (INCWDES ALL TESTS 1978-1982) ·-=-J --=}--=~l ]~-']1 I 1 1 1 1 1 60 iii Iii i',,"_'d"_i ......_-., LOW PLASTICITY OR "LEAN"CLAY PLASTIC OR "FAT'CU.Y;,; a SILTS am-IIMCO SUSITNA JOINT VENTURE 70 80 AUG /983 IFIGURE D 40 MH BOH 60 MEAN VALUES INCLUDE NON- PLASTIC,NON -VISCOUS DATA POINTS. A SIGNIFICANT NUMBER OF SAMPLES HAVE LIQUID LIMIT AND PLASTICITY' INDEX =O. ..- UPPER LIMIT OF PLASTICITY ALL UNITS ABOVE "Gil 5040 LIQUID LIMIT 30 WATANA DEVELOPMENT CL RELICT CHANNEL MATERIALS PLASTICITY SUMMARY 20 +0-We to 1....><1 >'»»:.--NATURA L MOISTURE .'.''.'I CONTENT-BORROW MATERIAL -cr ML CL CL-ML I l44J4"'l~I20»»(....'.,.,.,., 10 50 40 I Ill>1 .I I I I ~ x UJaz I I...:::1 I1:·:··1..•·.1,....>-......!::301 .u i= CIl« -la.. LEGEND I I ±I cr ON ALL UNITS C THROUGH F ®MEAN VALUE OF SAMPLES FROM UNITS INDICATED BY DESIGNATED LETTER (Q]1983 PROGRAM DATA COHESIONLESS MATERIALS (NP),, G,H,I,J,K~