HomeMy WebLinkAboutSusitna Hydro Aquatic Phase 2 Vol 3 1982SUSITNA HYDRO AQUATIC STUDIES
PHASE II BASIC DATA REPORT
Volume 3. Resident and
Juvenile Anadromous Fish Studies
on the Susitna River
Below Devil Canyon, 1982
•
ARLIS
Alaska Resources
Library & Information Services
Anchorage, Alaska
SUSITNA HYDRO AQUATIC STUDIES
PHASE II BASIC DATA REPORT
Volume 3. Resident and
Juvenile Anadromous Fish Studies
on the Susitna River
Below Devil Canyon, 1982
-by-
ALASKA_DEPARTMENT OF FISH AND GAME
Sus1tna Hydro Aquatic Studies
2207 Spenard Road
Anchorage, Alaska 99503
1983
PREFACE
This report is part of a five volume presentation of the fisheries,
aquatic habitat, and instream flow data collected by the Alaska Depart.,-
ment of Fish and Game (ADF&G) Susitna Hydroelectric (Su Hydro)
Feasibility Aquatic Studies Program during the 1981-82 (October-May)
ice-covered and 1982 open water (May-October) seasons. It is one of a
series of reports prepared for the Alaska ~ower Authority (APA) and
its principal contractor, Acres American (Acres) by the ADF&G and
other contractors to evaluate the feasibility of the proposed Susitna
Hydroelectric Project. This report is intended for data transmittal to
other Susitna Hydroelectric Feasibility Study participants. A
preliminary draft was circulated for review in February.
The topics discussed in Volumes Two through Five are illustrated in
Figure A. Volume One presents a synopsis of the information contained
in the other four volumes. Volume Two also includes a comparison of
1981 and 1982 adult anadromous fisheries data.
An ADF&G data analysis report will include an analysis of the
pre-project fishery and habitat relationships derived from this and
related reports prepared by other study participants. A review draft
will be circulated to study participants on May 1, 1983. The final
report will be submitted to the APA on June 30, 1983 for formal
distribution to study participants, state and federal agencies, and the
public. Also scheduled for completion on June 30, 1983 is the first
draft of the ADF&G 1982-83 ice-covered season basic data report. It
will include a presentation of 1982-83 incubation and other fishery and
habitat data.
These and other ADF&G reports (1974, 1976, 1977, 1978. 1979, 1981a,
b, c, d, e. f, 1982) and information reported by others will be
summarized and analyzed by the Arctic 'Envl.ronmental Information and
Data Center (AEIDC) to evaluate post-project conditions. Woodward
;
....... .......
Factors Influencing Aquatic Habitat Fish Life Phases Influenced by~ Habitat
River Morpholon
'lo1.4, Vol. !I
Chemical
Vol. 4, Vol !I
Figure A. Program elements presented in Volumes Two through Five.
Timino, Distribution
ond Population
Vol. 2, Vol. 4
butlon
Vol. 3, Vo1.4, Vol. !I
Clyde Consultants will, in turn, use this information to support their
preparation of the Federal Energy Regulatory Commission License Appli-
cation for Acres.
The five year (Acres 1980) ADF&G Su Hydro Aquatic Studies program
was initiated in November, 1980. It is subdivided into three ·study
sections: Adult Anadromous Fish Studies (AA), Resident and Juvenile
Anadromous Fish Studies (RJ), and Aquatic Habitat and Instream Flow
Studies (AH).
Specific objectives of the three sections are:
1. AA -determine the seasonal distribution and relative abun-
dance of adult anadromous fish populations produced within
the study area (Figure B);
2. RJ -determine the seasonal distribution and relative abun-
dance of selected resident and juvenile anadromous fish
populations within the study area; and
3. AH characterize the seasonal habitat requirements of
selected anadromous and resident fish species within the
study area and the relationship between the availability of
these habitat conditions and the mainstem · discharge of the
Susitna River.
The 1982 ADF&G portion (Figures C and D) of the overall feasibility
project study area (Figure B) was limited to the mainstem Susitna River
and the mouths of major tributaries. Portions of tributaries which will
be inundated by the proposed impoundments were also evaluated.
Descriptions of study sites are presented in each of these volumes
including the ADF&G reports (ADF&G 1981a, b, c, d, e, f).
The Susitna River is approximately 275 miles long from its sources in
the Alaska Mountain Range to its point of discharge into Cook Inlet.
Its drainage encompasses an area of 19, 400 square miles. The mainstem
i i i
-'•
<
0
• 'o. • ... ,
MAP AREA
0 25
..,"
/ ,;
Susitna Station
(RM 26.0)
I
I
Figure B. Susitna River drainage basin.
/
/
/
' ' ' .......... .......... .......... ',
' \
\
' I
I
I
I
I
I
a/
I -,/ /, .......... ____ -
• ADF 8G FIELD CAMPS
<
·······"~
0 25
' ', ........... .......... .......... ',
.,.*""' .,.
/
\
\
\
' I
r
I
I
I
I
I
l
1982 OPEN WATER
SEASON STUDY AREAS
~ UPPER RIVER
IEl STUDY AREA
~ LOWER RIVER
W STUDY AREA
. --DRAINAGE BOUNDARY
Figure C. 1982 ADF&G open water season (May through October) study area.
<
--'•
0
......... ..,
0
miles
'
25
' ' ............. .......... .......... .....
\
\
l
I
I
I
I
I
I
I
~/
/
/
1991-82 ICE-COVERED
SEASON STUDY AREAS
LOWER RIVER
STUDY AREA
UPPER RIVER
STUDY AREA
DRAINAGE BOUNDARY
Figure D. 1981-82 ADF&G ice-covered season (October through May) study area.
and major tributaries of the Susitna River, including the Chulitna,
Talkeetna and Yentna rivers, originate in· glaciers and carry a heavy
load of glacial flour during the ice-free months (approximately May
through October). There are many smaller tributaries which are
perennially clear.
Questions concerning these reports should be directed to:
Thomas W. Trent
Aquatic Studies Coordinator
Alaska Department of Fish & Game
Su Hydro Aquatic Studies Program
2207 Spenard Ro~d
Anchorage, Alaska 99503
Telephone (907) 274-7583
vii
PREFACE REFERENCES
Acres American, Inc. (Acres) 1980. Susitna Hydroelectric Project Plan
of Study. . frepared for the Alaska Power Authority. Anchorage,
Alaska.
Alaska Department of Fish and Game (ADF&G). 1974. An assessment
of the anadromous fish populations in the Upper Susitna River
Watershed between Devil Canyon and the Chulitna River.
Anchorage, Alaska.
1976. Fish and Wildlife studies related to the Corps of
Engineers Devil Canyon, Watana Reservoir Hydroelectric Project.
ADF&G. Anchorage, Alaska.
1977. Preauthorization assessment of the proposed Susitna
Hydroelectric Projects: preliminary investigations of water quality
and aquatic species composition. A:OF &G. Anchorage, Alaska.
1978. Preliminary environ111ental assessment of hydroelectric
development on the St~sitna River. Anchorage, Alaska.
·1979. Preliminary final plan of study fish and studies
proposed by the ADF&G. ADF&G. Anchorage, Alaska.
ADF&G. 1981a. Aquatic studies procedures manual. Phase I. Final
Draft. Subtask 7. 10. Prepared for Acres American,
Incorporated, by the · Alaska Department of Fish and Game I Su
Hydro. Anchorage, Alaska.
1981b. Adult anadromous fisheries project. Phase I. Final
Draft. Subtask 7.10. Prepared for Acres American,
Incorporated, by the Alaska Department of Fish and Game/Su
Hydro. Anchorage, Alaska.
viii
1981c. Aquatic habitat and instream flow project. Phase I.
Final Draft. Prepared for Acres American, Incorporated, by the
Alaska· Department of Fish and Game/Su Hydro. Anchorage,
Alaska.
1981d. Resident fish investigation on the lower Susitna River.
Phase I. Final Draft. Prepared for Acres American, Incorporated
by Alaska Department of Fish and Game/ Su Hydro. Anchorage,
Alaska.
1981e. Resident fish investigations on the lower Susitna
River. Phase I. Final Draft. ADF &G Su Hydro Aquatic Studies
Program. Anchorage , Alaska.
1981f. Resident fish investigations on the upper Susitna
River. Phase I. Final Draft. ADF&G Su Hydro Aquatic Studies
Program. Anchorage, Alaska.
1982. Aquatic Studies Program. Phase I. Final Draft.
Subtask 7.10. Prepared for Acres American, Incorporated by the
Alaska Department of ·Fish and Game/Su Hydro. Anchorage,
Alaska.
ix
TABLE OF.CONTENTS
PREFACE............................................................ i
LIST OF FIGUREs .. ~···· ............................................... xv
LIST OF TABLES ....................... ·.............................. XX
LIST OF PLATES .........•......•.................................... xxiv
1. OBJECTiv-E-s.................................................... 1
1.1 Distribution and Abundance Studies....................... 1
1.2 Emergence and Outmigration Studies....................... 3
1.3 Food Habits of Juvenile Salmon .......................... 5
2. METHO'DS ..•..•. : ... -..••..••••.....................•.. I • • • • • • • • • • 7
2.1 Distribution and Abundance Studies ....................... 7
2 .1.1
2 .1. 2
2.1.3
2 •. 1.4
Boat Electrofishing Studies.................... 7
Radiotelemetry Studies......................... 11
Designated Fish Habitat Studies ................ 16
2.1.3.1
2.1.3.2
2.1.3.3
·2.1.3.4
Sampling Sites and Reaches ........... 17
Hydraulic Zones ...................... 20
Biological Sampling .................. 23
Winter Season Methods. . . . . . . . . . . . . . . . 29
Other Methods.................................. 31
2.2 Emergence and Outmigration Studies....................... 31
2.3 Food Habits of Juvenile Salmon .. ~ ..•..................... 37
2.3.1
2.3.2
2.3.3
Field Sampling ...........•..................... 37
Laboratory Methods ..• '"........................ 43
Analytical Methods............................. 46
3. RESULTS ......................................................... 47
3.1 Distribution and Abundance Studies ....................... 47
3 .1.1 Resident Fish Species .......................... 47
3.1.1.1 Rainbow Trout ........................ 48
Distribution and Relative Abundance .. 48
Movement and Migration............... 50
Spawn i n g . . . • • . • . . . • • • . • . • . . . • • • . • • • . . 54
X
3 .1. 2
Page
3.1.1.2 Arctic Grayling ...................... 55
Distribution and Relative Abundance .. 55
Movement and Migration ............... 58
Spawning............................. 59
3.1.1.3 Burbot ............................... 59
Distribution and Relative Abundance .. 59
Movement and Migration............... 61
Spawning............................. 64
3.1.1.4 Round Whitefish ...................... 65
Dis~ribution and Relative Abundance .. 65
Movement and Migration............... 68
Spawning ........ -..................... 69
3.1.1.5 Humpback Whitefish ..................• · 69
Distribution and Relative Abundancei. 70
Movement and Migration ............... 72
Spawning............................. 72
3.1.1.6 Longnose Sucker ...................... 73
Distribution and Relative Abundance .. 73
Movement and Migration ............... 75
Spawning............................. 76
3.1.1.7 Dolly Varden ... · ...................... 77
Distribution and Relative Abundance .. 77
Movement and Migration ............... 80
Spawning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
3.1.1.8 Threespine Stickleback ............... 80
Distribution and Relative Abundance .. 80
Movement and Migration............... 83
Spawning............................. 83
3.1.1.9 Slimy Sculpin ........................ 83
Distribution and Relative Abundance .. 83
Hovement and ~1igration............... 86
Spawning............................. 86
3.1.1.10 Arctic Lamprey ....................... 87
Distribution and Relative Abundance .. 87
Movement and Migration ............... 87
Spawning............................. 89
Juvenile Anadromous Fish Species............... 89
3.1.2.1
3.1.2.2
3.1.2.3
3.1.2.4
3.1.2.5
Chinook Salmon ....................... 89
Coho Salmon .. ~ .. ~ .................... 100
Chum Salmon .......................... 111
Sockeye Salmon ................ r•••••• 118
Pink Salmon .......................... 125
xi
Page
3.2 Emergence and Outmigration Studies ....................... 126
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
Chinook·· Salmon ................................. 127
Coho Salmon .................................... 137
Chum Salmon .................................... 147
Sockeye Sa 1 man ................................. 153
Pink Salmon .................................... 159
3.3 Food Habits of Juvenile Salmon ........................... 161
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
Salmonid Collections ........................... 161
Important Food Types ........................... 161
Comparisons Between Species .................... 164
Electivity Indices ............................. 177
. Drift Samples Compared to Kick Screen Samples .. 177
Comparison of Invertebrate Populations
at Different Sites .......................... 178
4. DISCUSSION AND CONCLUSIONS .................................... 192
4.1 Distribution and Abundance ............................... 192
4.1.1 Resident Fish Specjes ....... , .................. 192
4.1.1.1 Rainbow Trout ........................ 192
Distribution and Relative Abundance .. 192
Adult Movement and Migration
Patterns ........................ 193
Spawning ............................. 196
Juvenile Rearing Areas ............... 196
4.1.1.2 Arctic Grayling ...................... 196
Distribution and Relative Abundance .. 197
Adult Movement and Migration
Patterns ........................ 200
Spawning ............................. 203
Juvenile Rearing Areas ............... 203
4. 1. 1. 3 Bu rbot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Distribution and Relative Abundance .. 205
Adult Movement and Migration
Patterns .........•.............. 205
Spawning ............................. 207
Juvenile Rearing Areas ............... 208
4.1.1.4 Round Whitefish .........•............ 209
Distribution and Relative Abundance .. 209
Adult Movement and Migration
Patterns ........................ 213
Spawning ............................... 214
Juvenile Rearing Areas .•............. 215
xii
4.1.2
Page
4.1.1.5 Humpback Whitefish ..•................ 216
Distribution and Relative Abundance .. 216
Adult Movement and Migration
Patterns ........................ 219
Spawning ........................... ~ . .220
Juvenile Rearing Areas ............... 221
4.1.1.6 Longnose Sucker ...................... 222
Distribution and Relative Abundance .. 222
Adult Movement and Migration
Patterns ........................ 225
Spawning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Juvenile Rearing Areas ............... 226
4.1.1~7 Dolly Varden ......................... 227
Distribution and Relative Abundance .. 228
Adult Movement and Migration
Patterns ........................ 230
Spawning ............................. 231
Juvenile Rearing Areas ............... 232
4.1.1.8 Threespine Stickleback ............... 232
Distribution and Relative Abundance .. 232
Adult Movement and Migration
Patterns .....................•.. 234
Spawning ............................. 234
Juvenile Rearing Areas ............... 235
4.1.1.9 Slimy Sculpin ........................ 235
Distribution and Relative Abundance .. 236
Adult Movement and Migration
Patterns ........................ 236
Spawning ..•.......................... 236
Juvenile Reating Areas ............•.. 237
4.1.1.10 Arctic Lamprey ...•................... 237
Juvenile Anadromous Fish Species ............... 238
. 4.1. 2.1
4.1.2.2
4.1.2.3
4.1.2.4
Chinook Salmon ....................... 238
Coho Salmon.; ........................ 241
Chum Salmon ................. · ......... 246
Sockeye Salmon .....................•. 248
4.2 Emergence and Outmigration ............................... 253
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
Chinook Salmon ........•......................... 253
Coho Salmon ............................•....... 256
Chum Salmon ..................................... 259
Sockeye Salmon ................................. 260
Pink Salmon ..................................... 262
xiii
5.
6.
7.
8.
Page
4.3 Food Habits a'nd Distribution of Food Organisms ........... 263
CONTRIBUTORS. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 272
ACKNOWLEDGEMENTS .••••••••••••••••••••••••••••••••••••••••••••• 274
LITERATURE CITED •••••••••••••••.•••••••••••••••••••••••••••••• 275
APPENDICES ...................................................... . E)
~Appendices are included under separate binder.
xiv
LIST OF FIGURES
Figure 3-2-1
Figure 3-2-2
Figure 3-2-3
Figure 3-2-4
Figure 3-3-1
Figure 3-3-2
Figure 3-3-3
Figure 3-3-4
Map of the Susitna River between Cook Inlet and
Devil Canyon showing major tributaries and field
stations, 1982.. .. . . . .•. .. .. . . .. . ......... .. .. . .. . ... .. .. 9
Map of Designated Fish Habitat (DFH) sites sampled
on the Susitna River, June through S~ptember, 1982 ....... 18
Hypothetical slough with associated tributary
showing hydraulic zones present at three mainstem
discharges............................................... 22
Map showing the location of the ·site on the Susitna
River where the downstream migrant trap was
operated, June 18 to October 12, 1982 .................... 33
Movement of five radio tagged rainbow trout in the
Susitna River, October 1981 to April 1982 ................ 51
Movement of five radio tagged burbot in the Susitna
River, October 1981 to April 1982 .............•.......... 63
The seasonal variation in distribution and relative
abundance of chinook salmon juveniles at DFH sites
on the Susitna River, June through .
September, 1982 ................... : ... · .................... 90
The total catch of chinook salmon juveniles by two
week periods for two reaches on the Susitna River, .
June through September, 1982 ............................. 94
Figure 3-3-5 Chinook salmon juvenile, mean catch per minnow trap
at DFH sites by reach on the Susitna River between
Goose Creek 2 and Portage Creek, June through
September, 1982. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 3-3-6 The seasonal variation in distribution and relative
abundance of coho salmon juveniles at DFH sites on
the Susitna River, June through September, 1982 .......... 102
Figure 3-3-7 The total catch of coho salmon juveniles by two week
periods for two reaches on the Susitna River, June
through September, 1982 .................................. 106
Figure 3-3-8 Coho salmon juvenile, mean catch per mirinow trap at
DFH sites by reach on the Susitna River between Goose
2 and Portage Creek, June through September, 1982 ........ 110
Figure 3-3-9 Seasonal variation in distributio~ and relative abun-
dance of chum salmon juveniles at DFH sites on the
Susitna River, June through September, 1982 .............. 112
XV
LIST OF FIGURES (Continued)
Figure 3-3-10 Total catch of chum salmon juveniles by two week
periods for two reaches on the Susitna River, June
through September, 1982 .................................. 116
Figure 3-3-11 Percentages of the total chum salmon juvenile catch
caught in two reaches of the Susitna River, June
through September, 1982 .................................. 117
Figure 3-3-12 Seasonal variation in distribution and relative
abundance of sockeye salmon juveniles at DFH sites
on the Susitna River, June through
September, 1982. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Figure 3-3-13 Total catch of sockeye salmon juveniles by two week
periods for two reaches of the Susitna River, June
Figure 3-3-14
Figure 3-3-15
Figure 3-3-16
Figure 3-3-17
through September, 1982 .................................. 123
Percentages of the total sockeye salmon juvenile
catch caught in twb reach~s of the Susitna River,
June through, September, 1982 ............................. 124
Chinook salmon juveniles, downstream migrant trap
catch rate averaged by three day periods, June
through October, 1982 ...... ~···~························· 129
Downstream migrant trap catch rates by three day
periods for juvenil~ chinook, coho, chum, and
sockeye sa 1 man, June 18 through October 12, 1982. . . . . . . . . 130
Coho salmon juveniles, downstream migrant trap
catch rates averaged by three day periods, June
through October, 1982 .................................... 139
Figure 3-3-18 Chum salmon juveniles, percent of total catch
by all gear types by reach of river averaged
by two week period on the Susitna River
between Cook Inlet and Devil Canyon, 1982 ................ 148
Figure 3-3-19 Chum salmon juveniles, downstream migrant trap
catch rates averaged by three day periods, June
through August, 1982 ..................................... 149
Figure 3-3-20 Sockeye salmon juveniles, downstream migrant trap
catch rates averaged by three day periods, June
through October, 1982 ...........................•..•..... 155
Figure 3-3-21 Stomach contents of chinook salmon juveniles
collected in Slough 8A during August, 1982 ......••.•..... 165
xvi
LIST OF FIGURES (Continued)
Figure 3-3-22 Stomach contents of chinook salmon juveniles
collected in Slough 11 during August and
September, 1982 .......................................... 166
Figure 3-3-23 Stomach contents of chinook salmon juveniles
collected in Slough 21 during August and
September, 1982 .................. ,·.. . . . . . . . . . . . . . . . . . . . . . 167
Figure 3-3-24 Stomach contents of chinook salmon juveniles
collected in Fourth of uuly Creek during August and
September, 1982 .................. ' ........................ 168
Figure 3-3-25 Stomach contents of chinook salmon juveniles
collected in ,Indian River during August and September,
1982 ....................................................• 169
Figure 3-3-26 Stomach contents of coho salmon juveniles collected
in Sl6ugh 8A during August and S~ptember, 1982 ........... 170
Figure 3-3-27 Stomach contents of coho salmon juveniles collected
in Slough 11 during September, 1982 ...................... 171
Figure 3-3-28 Stomach contents of coho salmon juveniles collected
in Fourth of July Creek during August and September,
1982 e • e • I I I I I I I I I I I I I I I I I I I I 8 • I I I I I I _I .. I I I I I I I I I I I I I I I I I I I 17 2
Figure 3-3-29 Stomach contents of coho salmon juveniles collected
in Indian River during August and September, 1982 ........ 173
Figure 3-3-30 Stomach contents of sockeye salmon juveniles
collected in Slough 8A during August and September,
1982 ............................... · ...................... 174
Figure 3-3-31 Stomach contents of sockeye salmon juveniles
collected in Slough 11 during August and September,
1982 I I I I I I I I I I I I I I I I I I I I I I 1,1 I I I I I I I I I I I 1 1 1 1 I I I I I I I I 1 1 1 1 I I 175
Figure 3-3-32 Percent frequency of major invertebrate types found
in drift net samples taken in Slough 8A during
August and September, 1982 .............•................. 180
Figure 3-3-33 Percent frequency of major invertebrate types found
in drift net samples taken in Slough 11 during
August and September, 1982 ...... .' .. ~ ..................... 181
Figure 3-3-34 Percent frequency of major invertebrate types found
in drift net samples taken in Slough 20 during
August and September, 1982 ............................... 182
xvii
LIST OF FIGURES (Continued) .
Figure 3-3-35 Percent frequency of major invertebrate types found
in drift net samples taken in Slough 21 during
August and September, 1982 ............................... 183
Figure 3-3-36 Percent frequency of major invertebrate types found
in drift net samples taken in Fourth of July Creek
during August and September. 1982. . . . . . . . . . . . . . . . . . . . . . . . 184
Figure 3-3-37 Percent frequency of major intertebrate types found
in drift net samples taken in Indian River during
August and September, 1982 ............................... 185
Figure 3-3-38 Percent frequency of major invertebrate types found
in kick screen samples taken in Slough 8A and Slough
11 during August and September, 1982. . . . . . . . . . . . . . . . . . . . . 186
Figure 3-3-39 Percent frequency of major invertebrate types found
in kick screen samples taken in Slough 20 and Slough
21 during·August and September, 1982 ..................... 187
Figure 3-3-40 Percent frequency of major invertebrate types found
in kick screen samples taken in Fourth of July Creek
Figure 3-4-1
Figure 3-4-2
Figure 3-4-3
Figure 3-4-4
Figure 3-4-5
and Indian River during August and September, 1982 ..•.... 188
Rainbow trout, catch per unit of boat electro-
fishing effort at tributary and mainstem sites on
the Susitna River between Cook Inlet and Devil
Canyon, May to September, 1982 ...................... 194
Arctic grayling, catch per unit of boat electro-
fishing effort at tributary and mainstem sites on
the Susitna River between Cook Inlet and Devil
Canyon, May to September, 1982. . . . . . . . . . . . . . . . . . . . . . 199
Length percent frequencies of Arctic grayling
captured by boat electrofishing at tributary or
slough and mainstem sites on the Susitna River below
Devil Canyon, May through September, 1982 ........... 201
Round whitefish, catch per unit of boat electro-
fishing effort at tributary and mainstem sites on
the Susitna River between Cook Inlet and Devil
Canyon, May to September, 1982 ...................... 211
Length percent frequencies of round whitefish
captured by boat electrofishing at tr·ibutary or
slough and mainstem sites on the Susitna River below
Devil Canyon, May through September, 1982 ........... 212
xviii
LIST OF FIGURES (Continued)
Figure 3-4-6
Figure 3-4-7
Figure 3-4-8
Figure 3-4-9
Humpback whitefish, catch per unit of boat electro-
fishing effort at tributary and mainstem sites on
the Susitna River between Cook Inlet and Devil
Canyon, May to September,-1982 .. ~ ......•............. 217
Longnose sucker, catch per unit of boat electro-
fishing effort at tributary and mainstem sites on
the Susitna River between Cook Inlet and Devil
Canyon, May to September, 1982 ...................... 224
Dolly Varden, catc:1 per unit ,of boat electrofishing
effort at tributary and mainstem sites on the Susitna
River between Cook Inlet and Devil Canyon, May to
September, 1982 ..................................... 229
Adjusted cumulative catch data by species for
juvenile chinook, coho, chum, and sockeye salmon
collected in the downstream migrant trap, June 18
through October 12, 1982 ............................ 255
xix
LIST OF TABLES
Table 3-2-1
Table 3-2-2
Table 3-2-3
Table 3-3-1
Table 3-3-2
Table 3-3-3
Table 3-3-4
Table 3-3-5
Designated Fish Habitat (DFH) sites sampled on the
Susitna River, June through September, 1982 .............. 19
Description of habitat zones sampled at DFH sites on
the Susitna River, June through September, 1982 .•........ 21
Six DFH sites on the Susitna River and the dates on
which they were sampled by the Food Habitats Investi-
gation Group, August to September, 1982.................. 39
'· ' ~ I
Rainbow trout catch on the Sustina River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Arctic grayling catch on the Susitna River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982............................................ 56
Burbot catch on theSusitna River between Cook Inlet and
Devil Canyon by study site type, May to
October, 1982 ........................... ~ . . . . . . . . . . . . . . . . 60
Round whitefish catch on the Susitna River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982 ............................................ 66
Humpback whitefish catch on the Susitna River between
Cook Inlet and Devil Canyon by study site type, May to
October, 1982............................................ 71
Table 3-3-6 Longnose sucker catch on the Susitna River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982 ............................................ 74
Table 3-3-7 Dolly Varden catch on the Susitna River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982 ..... ,. . . . .. . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . 78
Table 3-3-8 Threespine stickleback catch on the Susitna River between
Cook Inlet and Devi1 Canyon by study site type, May to
October, 1982............................................ 81
Table 3-3-9 Slimy sculp·in catch on the Sustina River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Table 3-3-10 Arctic lamprey catch on the Susitna River between Cook
Inlet and Devil Canyon by study site type, May to
October, 1982............................................ 88
XX
LIST OF TABLES (Continued)
Table 3-3-11 Total catch of chinook salmon juveniles by all gear
types at DFH sites on the Susitna River between Goose
Creek and Chulitna River, June through
September, 1982 .................. ~...... ... . . . . . . . . . . . . . . . 92
Table 3-3-12 Total catch of chinook salmon juveniles by all gear
types at DFH sites on the Susitna' River between Chulitna
River and Portage Creek, June through
September, 1982 .......................................... 93
Table 3-3-13 Chinook salmon juvenile, mean catch per minnow trap at
DFH sites on the Susitna River between Goose Creek and
Chulitna River, June through September, 1982 ............. 96
Table 3-3-14 Chinook salmon juvenile, mean catch per minnow trap at
DFH sites on the Susitna River between Chulitna River
and Portage Creek, June through September, 1982 .......... 97
Table 3-3-15 Chinook salmon juvenile, mean catch per minnow trap at
DFH sites by reach on the Susitna River between Goose
Creek 2 and Portage Creek, June through
September, 1982. . . .. . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . 98
Table 3-3-16 Total catch of coho salmon juveniles by all gear types
at DFH sites on the Susitna River between Goose Creek 2
and Chulitna River, June through September, 1982 ......... 103
Table 3-3-17 Total catch of coho salmon juveniles by all gear types
at DFH sites on the Susitna River between Chulitna River
and Portage Creek, June through September, 1982 ........•. 104
Table 3-3-18 Coho salmon juvenile mean catch per minnow trap at DFH
sites on the Susitna River between Goose Creek 2 and
Chulitna River, June through Septemb'er, 1982 ............. 107
Table 3-3-19 Coho salmon juvenile mean catch per minnow trap at DFH
sites on the Susitna River between Chulitna River and
Portage Creek, June through September, 1982 .............. 108
Table 3-3-20 Coho salmon juvenile mean catch per minnow trap at DFH
sites by reach on the Susitna River between Goose Creek
2 and Portage Creek, June through September, 1982 ........ 109
Table 3-3-21 Total catch of chum salmon juveniles by all gear types
at DFH sites on the Susitna River between Goose Creek 2
and Chulitna River, June through September, 1982 ......... 113
Table 3-3-22 Total catch of chum salmon juveniles by all gear types ·
at DFH sites on the Susitna River between Chulitna River
and Portage Creek, June through September, 1982 ....•... ~. 115
xxi
LIST OF TABLES (Continued)
Table 3-3-23 Total catch of sockeye salmon juveniles by all gear types
at DFH sites on the Susitna River between Goose Creek 2
and Chulitna River, June thro~gh September, 1982 ......... 121
Table 3-3-24 Total catch of sockeye salmon juveniles by all gear
types at DFH sites on the Susitna River between Chulitna
River and Portage Creek, June through
September, 1982 .......................................... 122
Table 3-3-25 Chinook salmon juveniles, scale analysis of age class
composition for collected fish by survey period between
Cook Inlet and Devil Canyon, 1982 ........................ 132
Table 3-3-26 Chinook salmon juveniles, mean length and range of
lengths between Cook Inlet and Chulitna, and between
Chulitna and Devil Canyon, February to
A.pri 1 , 1982. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Table 3-3-27 Chinook salmon juveniles, mean length and range of
lengths by age class between the Chulitna River
confluence and Devil Canyon, May to October,
1982 ...................................................... 134
Table 3-3-28 Chinook salmon juveniles, mean length and range of
lengths by age class between Cook Inlet and the Chulitna
River confluence, May to October, 1982 ................... 136
Table 3-3-29 Coho salmon juveniles, mean length and range of lengths
by age class between Cook Inlet and Devil Canyon,
February to April, 1982 .................................. 141
Table 3-3-30 Coho salmon, scale analysis of age class composition for
juvenile fish by survey period collected between Cook
Inlet and Devil Canyon, 1982 ............................. 142
Table 3-3-31 Coho salmon age 0+ and age l+ mean length and range of
lengths by survey period between the Chulitna River
confluence and Devil Canyon, June to
October, 1982. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
Table 3-3-32 Coho sal~on 'age 0+ and age 1+ mean length and range of
lengths by survey period between Cook Inlet and the
Chulitna River confluence, May to
September, l982. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Table 3-3-33 Chum salmon fry, mean length and range of lengths by
survey period and by reach of river, March to
September, 1982 .......................................... 152
xxii
LIST OF TABLES (Continued)
Table 3-3-34 Sockeye salmon, scale analysis of age class composition
for juvenile fish by survey period collected between Cook
Inlet and Devil Canyon, 1982 ............................. 157
Table 3-3-35 Sockeye salmon age 0+ and age 1+ mean length and range of
lengths by survey period between the Chulitna River
confluence and Devil Canyon, 1982 ...•.................... 158
Table 3-3-36 Sockeye salmon age 0+ and age 1+ mean length and range of
lengths by survey perioci below the Chulitna River
confluence, June through September, 1982 ................. 160
' .
Table 3-3-37 Pink salmon fry collected by site for the combined
studies, 1982 .........•....•.............................. 162
Table 3-3-38 Numbers of juvenile salmon captured and retained at six
Designated Fish Habitat sites in the upper reach of the
Susitna River in August and September, 1982 ..........•..• 163
Table 3-3-39 Results of chi-square analsyses, comparing percent
composition of major invertebrate taxa in stomach
contents of co-occuring species of salmonid
juveniles ................................................. 176
Table 3-3-40 Results of chi-~quare analysis comparing
proportions of invertebrates collected in
drift net and ·kick screen samples ......................... 179
Table 3-3-41 Results of chi-square analyses comparing
percent composition of invertebrate taxa
in drift net samples ..................................... 189
xxiii
LIST OF PLATES
Plate 3-2-1
Plate 3-2-2
Plate 3-2-3
Plate 3-2-4
Plate 3-2-5
Plate 3-2-6
Plate 3-2-7
Plate 3-2-8
Plate 3-2-9
PAGE
Electrofishing with a boat mounted electroshocking
unit at Mainstem Susitna-gravel bar opposite Montana
Creek (RM 78.0).......................................... 8
Surgical implantation of a radio transmitter into a
burbot at Mainstem Susitna (RM 84.1) ..................... 13
Beach seining along a gravel bar at Indian River -
Helicopter Site 1 (TRM 2.7) .......................•...... 24
Electrofishing with a backpack electroshocker at
Slough 8 (RM 113.6) .......................•.............. 25
Tagging burbot with Floy anchor tags at Whitefish
Slough (RM 78.7) .............................•...•....... 27
Necropsyinq a burbot to determine its sex and relative
maturity at Portage Creek mouth (RM148.8)................ 28
Winter samp 1 i ng techniques. . . . . . . . • . . . . . . . . . . . . . . . . . . . . . . 30
Downstream migrant trap fishing at its mainstem Susitna
River locatfon at river mile 103.0....................... 34
Downstream migrant trap operation and sample
catch, 1982 ............................. ·-·............... 36
Plate 3-2-10 Minnow trap set in a typical juvenile salmon rearing
habitat at Slough 21 (RM 142.5) .......................... 40
Plate 3-2-11 Kick screen used for sampling invertebrates .............. 42
Plate 3-2-12 Invertebrate sampling with a stream drift net at
Slough 21 (RM 142.5) .•................................... 44
Plate 3-2-13 Sorting field samples of invertebrates in the lab
with the aid of a dissecting scope ....................... 45
xxiv
1. OBJECTIVES
1.1 Distribution and Abundance Studies
The development of hydroe 1 ectri c power has frequently been associ a ted
with downstream changes on the aquatic environment. These changes
include effects on the amount of water available for fish~ (the
11 instream flow 11 available), changes in water quality, and corresponding
changes to all components of the aquatic communities.
The resident and juvenile anadromous species have been studied during
the 1981 and 1982 field season with two major goals to be accomplished:
1. Provide an inventory of the baseline resources that may be
affected by the development of the Susitna hydroelectric
project.
2. Determine which factors are limiting their freshwater survival
and production, with emphasis on those factors which may be
influenced by the development of the hydroelectric projects.
This report provides baseline data on the distribution and relative
abundance of the resident and juvenile anadromous species, primarily
directed at meeting the first goal. This data base was also collected
using study designs that would further address the second goal. Further
data from this study are presented in the habitat report (Vol. 4) as it
contributes to our understanding of the response of the fish populations
1
to the variable habitat conditions that exist in the Susitna River.
To accomplish these goals, some intermediate objectives of these studies
were established. These include the following:
A. Determine the geographical and seasonal distribution and
relative abundance of all resident and juvenile anadromous
species.
B. Examine a wide array of habitat conditions to document the
presence or absence of species in areas not previously
surveyed.
C. Collect baseline information on resident species such as age
distribution, length distribution, growth, sex ratio,
migration and mo~ement, spawning~ and rearing.
D. Collect baseline information for juvenile anadromous species
on age distribution, length distribution, growth, rearing
areas, and outmigration.
The studies were confined primarily to the reach of the Susitna River
above the Chulitna confluence, where the major effects of the project
are anticipated. Representative sites in the reach of river below the
confluence were also studied.
2
1.2 Emergence and Outmigration Studies
Development of hydroelectric power has been associated with changes in
the downstream aquatic environment, often creating deleterious effects
on downstream fisheries. In order to predict adverse or beneficial
effects of the changes that are associated with th~ ~evelopment of large
scale hydroelectric power on the Susitna River, an inventory of the
resources below the project and development of an understanding of the
critical portions of the life cycle of the fish is necessary. One
important factor is the rate of development of the embryos and
subsequent emergence and outmigration. It is known from other systems
that this portion of the life cycle is critica·l to the well being of the
populations and small changes in timing or in other associated
en vi ronmenta 1 parameters may cause major changes in the survi va 1 of
these species.
To evaluate the potential impacts associated with the Susitna
'
hydroelectric project and to allow the development of mitigation
strategies, certain types of information are required. The following
goals of the emergence and outmigration studies of the resident and
juvenile anadromous program should meet this information requirement.
1. Develop an understanding of the emergence and outmigration of
juvenile salmon and selected resident species in the Susitna
River reaches which may be affected by the development of
hydroelectric power.
3
2. Determine which phys i ochemi ca 1 factors of the Sus i tna River
are critical determinants of the timing of emergence and
outmigration in the various habitat types and how alteration
of these factors might affect survival of the species being
evaluated.
This report provides baseline data on the temporal movement of
outmigrating species and preliminary information on emergence rates.
Baseline condition of the species collected, including size, age, and
other important factors are reported. Specific objectives addressed in
this baseline data report are as follow:
A. Determin~ the timing of downstream migration of juvenile
salmon from the reach of the Susitna River above the Chulitna
confluence.
B. Provide basic biological data including species, age class,
and length to determine the relative condition and stage of
deve 1 opment of the species .co 11 ected.
C. Provide preliminary baseline data for determining the rates of
embryonic development and emergence times of the early 1 ife
stages of Susitna River salmon.
D. Provide baseline data for determining how development of
incubation rates, emergence times and outmigration timing
correlate with natural changes in en vi ronmenta 1 conditions
measured.
4
E. Provide descriptions of the variabflity of the biological
development and outmigration behavior among the different
species and within a given species.
These data, and their subsequent analysis in the Fish and Habitat
Relationships report, will provide the basis fot meeting the major goals
of the emergence and outmigration studies.
1.3 Food Habits of Juvenile Salmon
A major factor influencing the distribution and abundance of rearing
juvenile salmon is the food base supporting these fish. Historically,
hydroelectric projects are accompanied by changes in discharge, water
temperature and water quality of a river system. These changes often
affect the system's benthic invertebrate community (Ward and Stanford,
1979). In the Susitna River, primary questions regarding the juvenile
salmonid populations are: (1) are existing populations. of juvenile
salmon limited by the availability of rearing areas? and, (2) does the
naturally occurring variability of environmental parameters and benthic
invertebrate communities suggest that dam-induced changes in these
parameters will affect the juvenile salmonid populations in. the system?
The goals of the food habits study are to enlarge our understanding of
the rearing properties of the system, and to determine which aspects may
be highly sensitive to change.
This preliminary investigation of the salmonid population•s relationship
to their food base has two major objectives. The first is to describe
5
the food habits of the juvenile salmon present at each site. The second
objective is to qualitatively describe invertebrate communities at
\ \ \ I
different habitat sites, and to make comparisons between those commu-
nities. From this it 'is 'hoped that environmental variability between
sites can be related to observed differences in invertebrate community
structure. Corollary to this, because of the large differences in water
quality, morphology, and hydraulic properties present at the habitats
sampled, the biological information obtained will provide insights into
·whether changes in . hydraulic parameters can be expected to provide a
large change in the composition of the invertebrate communities.
The mid-summer (July 1, 1982) starting date for this investigation
limited the scope of the study. Rearing of sockeye salmon and of
certain age classes of. ch_,inol?k salmon could not be effectively studied
because the majority of them had outmigrated by the time sampling began.
Similarly, the limited freshwater rearing of chum salmon could not be
effectively studied. Investigation of these age classes and species
will begin during the spring of 1983.
6
2. METHODS
2.1 Distribution and Abundance Studies
2.1.1 Boat Electrofishi~
A boat-mounted electrofishing unit was used to sample resident fish
populations in the Susitna River between Cook Inlet and Devil Canyon
from ice-out to freeze-up, 1982 {Plate 3-2-1). Two additional electro-
fishing boats assisted in the sampling of resident fish populations
during mainstem salmon spawning surveys conducted in August and
September.
A wide variety of sites were sampled by electroflshing crews during
1982. These included tributary, slough, side channel, and mainstem
sites on the Susitna River between RM 7.2 and RM 150.1 {Figure 3-2-1).
Seventeen Designated Fish f:iabitat {DFH) sites were, sampled twice monthly
with boat-mounted electrofishing gear during the ice free months
{Appendix Table 3-A-1). During periods of low mainstem flows, however,
many of the DFH sites were inaccessible by boat and therefore could not
be sampled. Normally only backwater areas or mixing areas were sampled
at these sites.
In addition to the DFH sites, a large number of Selected Fish Habitat
{SFH) sites in the mainstem, at sloughs, and at mouths of tributaries
were also sampled with boat electrofishing gear {Appendix Table 3-A-2).
Some of these SFH sites were sampled monthly, in order to document
7
00
Plate 3-2-1. Electrofishing with a boat mounted electroshocking ·unit at Mainstem Susitna-gravel bar
opposite Montana Creek (RM 78.0).
GOLD CREEK STATION
SUNSHINE STATION
. -·
Figure 3-2-1. Map of the Susitna River between Cook Inlet and Devil
Canyon showing major tributaries and field stations,
1982'.
9
seasonal changes in fish populations. However, most of the SFH sites
were sampled only once or possibly several times at random intervals
during the course of the season.
The length of time spent electrofishing a site ranged from one minute to
75 minutes. The area of sites electrofished also varied tremendously;
some sites were fished for a distance of 20 yards while at other sites,
drifts ranged in length up to several miles. A site often encompassed a
variety of fish habitats with varying substrates, water velocities,
turbidities and depths.
These procedures were used to cover the broad range of habitat con-
ditions that exist in .this system. Data col1ected at each site included
time fished, distance fished~ and catch information. Bi ol ogi ca 1 data
were collected on all resident fish captured and adult resident fish
were tagged as specified· in the procedures manual (AOF&G, 1982).
Recaptures were also recorded. Initially, burbot (Lota lota L.) were
tagged with disc dangler tigs and all other resident species were tagged
with Floy anchor tags .. After observing tag retention on several burbot
that were Floy anchor tagged during the 1981 field season and recaptured
in May 1982, a decision was made to also tag burbot with Floy anchor
tags.
Scales were taken from captured resident fish (humpback and round
whitefish, rainbow trout, Arctic grayling, and longnose sucker) during
field sampling for age-length analysis according to methods and sampling
schedules outlined in the procedures manual (ADF&G, 1982). In
10
addition, scales were taken from juvenile anadromous species. Otoliths
were taken from burbot and Dolly Varden mortalities for aging.
At all sites where adult resident fish spawning was documented, habitat
measurements of water chemistry, water velocity, and substrate compo-
sition were taken as specified in the procedures manual (ADF&G, 1982).
A map of the spawning site was also drawn. A representative sample of
water temperature and conductivity was also collected from a number of
other sites where electrofishing was conducted but no spawning activity
was found.
2.1.2 Radio Telemetry
Radio telemetry equipment used in this study was developed by Smith Root
Corporation in Vancouver, Washington. Equipment consisted of a low
frequency (40 MHz) radio tracking receiver (Model RF-40), a loop antenna
(Model LA-40) and ten transmitters (Model P40-500L 3V)~ This equipment
was also used in the study of adult anadromous species (ADFG, 198la).
The transmitters used were cigar shaped, encapsulated in plastic, and
had an external 17.0 centimeter (em) antenna. The transmitters measured
5.3 em in length and were 1.6, em in diameter; each tag weighed
approximately 13.0 grams {gm) dry (approximately 2.6 gm in water). The
power source for the transmitter was a 1 ithium, three volt battery which
provide a life expectancy of approximately 150 days. Different
frequencies, between 40.740 and 40.770 MHz, or pulse rates or both were
used to differentiate between the ten radio tags. The radio tags were
11
measured to the nearest millimeter (mm) (fork length for rainbow trout
and total length for burbot). Scales wer€ taken from the rainbow trout
for aging purposes, however, they were regenerative and unreadable.
Burbot were tagged with di1SC dangl€r tags and 'rainbow trout were tagged
with Floy anchor tags.
A transmitter was then surgically implanted in the coelom using a
procedure similar to that described by Ziebell (1973) (Plate 3-2-2). A
three to five em incision was made approximately one em to the left and
parallel to the mid-lin~ of the ventral surfa~e, cutting posteriorly
beginning slightly behind the pectoral fins. The radio tag was then-
inserted with the antenn'a to the posterior of the ·fish. Each incision
was closed with seven or eight individual silk sutures.
Each fish was then plac;ed into a live box and held upright unt"il it
regained equilibrium from the effects of the anesthesia. The fish were
held overnight for observation. The sutures were then checked and the
implanted transmitter's signal was tested. Each fish was then released
in the vicinity of its capture area.
The ten fish were radio tracked by boat, aircraft or snowmobile until
April 6, 1982 when only one of the radio tagged fish was located. The
batteries from the other nine radio tags implanted in rainbow trout and
burbot were assumed to have expired. Aerial tracking proved to be the
most efficient method for locating the fish in comparison to the other
methods described. Radio tracking by boat was last attempted on October
30 due to the presence of slush ice in the Susitna River.
12
Plate 3-2-2. Surgical implantation of a radio transmitter into a burbot
at Mainstem Susitna (RM 84.1).
13
immersed in water for 48 hours and then tested for signal strength and
frequency before they were implanted in fish.
Rainbow trout (Salmo gairdneri Richardson) and burbot were selected as
the target resident species for the 1981-1982 radio telemetry studies in
the lower river. Based on personal communications with Carl Burger
(USFWS}, a minimum length was determined for each species to be radio
tagged. Three hundred and fifty mm was selected as the min·imum fork
length for rainbow trout and 550 mm the minimum total length for burbot.
It was felt that fish smaller than these minimum sizes would not be able
to tolerate the implant~d radio tags.
Five burbot and five rainbow trout captured in the Susitna River between
RM 76.3 and RM 84.1 from October 3rd to October 15, 1981 were used for
telemetry studies (Appendix Table 3-A-3). The rainbow trout and two of
the burbot were captured by electrofishing. These fish were held
overnight in live boxes for observation, prior to being radio tagged.
The following day, each fish was observed to make sure it had fully
recovered from being electroshocked and was suitable for radio tagging.
The other three burbot were captured on trotlines. The condition of
trotline caught fish was assessed as they were captured and those that
were healthy and vigorous were selected to be radio tagged that same
day. No injured or lethargic fish were radio tagged.
Each fish determined to be suitable for radio tag implantation was
placed in a holding box and anesthetized with MS-222 (tricaine methane-
sulfonate). After the fish were anesthetized, their lengths were
14
-
Aeri a 1 tracking procedures utilized were identi ca 1 to methods used and
described by Adult Anadromous Investigations (ADF&G, l981a). Aeria 1
flights were conducted between October 14, 1981 and April 6, 1982. The
time period between tracking flights ranged between six and 24 days but
was generally done at approximately two week intervals.
Radio tracking flights during October to January 6 were conducted only
along the mainstem Susitna R1ver from the mouth of the Deshka River (RM
40.6) to the mouth of the Talkeetna River (RM 97.0). Due to an increase
in the number of radio tagged fish that were not located on the December
28 and January 6 flights, the search was expanded on the subsequent
flight on January 14th, by beginning at the mouth of the Susitna River
(RM 0.0) and radio tracking along the mainstem Susitna River to
Talkeetna (RM 97.0).
Subsequent flights after January 6 also included periodically searching
five major tributaries of the Susitna River, [Montana Creek (RM 77.0),
Kashwitna River (RM 61 .. 0), Deshka River (RM 40.6), Yentna River (RM
28.5), and Alexander River (RM 10.1)], upstream as far as ten miles from
their mouths.
Recapture of five of the radio tagged fish was attempted in February and
March to recover the soon to be expired radio tags. The fish were first
located by aeria1 tracking. Biologists then traveled to these sites on
snowmobiles and set gillnets and trotlines in the vicinity of the radio
tagged fish.
15
Other purposes for conducting the surveys were: to find the maximum
range of the radio tags on ground during the winter (observe the effects
of ice on the transmitter•s signal); to find if the areas where the
radio tagged fish were located were. areas where large concentrations of
resident fish gathered during the winter; to examine the radio tagged
fish to observe effects resulting from the surgery to internally implant
the radio tags; to examine the habitat where the radio tagged fish were
located; and to determine if the radio tagged fish were still alive.
2.1.3 Desig,nate~ ftsh Habitat Studies
The study of resident and juvenile anadrornous . species at specific
habitat sites, begun i,n June 1982, reflects a change in emphasis from
the 1981 re.sident a.nd juvenne anadrornou,s prog.ram. The studies changed
from the collection of broad-based dJstribution and bi o 1 ogi ca 1 data of
resident and juvenile a.nad:r;-omous fish€s to. pro vi ding a more detai 1 ed
study of the aquati.c envir:;onrnental factors affecting their distribution
and relative abundance.. The sampling design was based upon the
hypothesis that the d~ stributi on of resident and juveni 1 e anadromous
fishes is related to the influence of the mainstem stage on the aquatic
environments associated with sloughs and tributaries. The methods used
for the 1981-1982 winter sampling were the same as those of the
1980-1981 winter season (ADF&G 1982).
H)
2 .1. 3.1 Sampling sites and rea,ches
The specific habitat studies investigated the tr'ibutary mouths, sloughs,
and limited mainstem sites that were influenced by changes in mainstem
Susitna River discharge. These sampling locations were selected based
on data collected during 1981 studies which indicated. that these sites
contained significant resident and juyenile anadromous fish populations
or important habitat.
Seventeen Designated Fish Habitat (DFH) sites, ranging from Goose Creek
(RM 73.1) to Portage Creek (RM 148.8), were chosen for the study (Figure
3-2-2 and Table 3-2-1). A general description of each site including an
aerial photograph is included in Appendix F of Vol. 4. These sites were
sampled from June through September (Appendix Table 3-A-1). Two sampl-
ing trips, approximately 8 to 9 days in duration, were made each month.
Additionally, two DFH sites (Portage Creek mouth and Slough 20) were
'
sampled in early October. Increasing slush ice prevented access to the
other sites. The only catch was two burbot .caught on a trotl i ne at
Portage Creek. This sampling period is not discussed further.
The section of the river sampled was divided into two reaches. The
upper reach ranged from the Chulitna River confluence (RM 98.4) to
Portage Creek (RM 148.8). The lower reach ranged from Goose Creek (RM
73.1) to the Chulitna River confluence and included the discharge of two
major tributaries, the Chulitna River and Talkeetna River.
Additionally, five Selected Fish Habitat (SFH) sites on the Susitna
River [Gash Creek and Side Channel (RM 111.5), Mainstem Susitna -Curry
17
INDIAN R. MOUTH-
9
SA
AND SLOUGH
CREEK AND SLOUGH
unlllin•;C ''
SUNSHIN.£ CREEK AND SIDECHANNEL
M---WHlTEFlSH SLOUGH
CREEK-2 AND SIDECHANNEL
' .
Figure 3-2-2 •. r~ap of Designated Fish Habitat (DFH) sites sampled on the
Susitna River, June through September, 1982.
18
Table 3-2-1. Designated Fish Habitat (DFH) sites sampled on the
Susitna River, June through October, 1982.
Site Geogra12hic Code River Mile
Goose Creek to Chulitna Reach
Goose Creek 2 and Side Channel S 23N 04W 30 BBC 73.1
Whitefish Slough S 23N 05W 01 BBC 78.7
Rabideux. Creek and Slough S 24N 05W 16 AAC 83.1
Sunshine Creek and Side Channel S 24N 05W 14 AAB 85.7
Birch Creek and Slough S 25N 05W 25 DCC 88 .4.
Chulitna to Portage Creek Reach
Whiskers Creek and Slough S 26N 05W 03 ADB 101.2
Slough 6A S 28N 05W 13 CAC 112.3
Lane Creek ~nd Slough 8 S 28N 05W 12 ADD 113.6
Slough 8A S 30N 03W 16 BCD 125.3
Slough 9 S 30N 03W 16 BDC 129.2
4th of July Creek, Mouth S 30N 03W 03 DAC 131.1
Slough 11 S 31N 02W 19 DOD 135.3
Indian River, Mouth S 31N 02W 09 CDA 138.6
Slough 19 S 31N 02W 10 DBB 140.0
Slough 20 S 31N 02W 11 BBC 140.1
Slough 21 S 31N 02W 02 AAA 142.0
\
Portage Creek, Mouth S 32N 01W 25 CAC 148.8
19
(RM 120.7), Slough 10 (RM 133.8), Slough 16 {RM 137.7) and Slough 22 (RM
144.3)] were sampled, but on an irregular basis (Appendix Table 3-A-2).
Also, three SFH sites on ~pper Indian River were sampled once a month
with fry traps from June through September and three SFH sites ·in upper
Portage Creek were sampled once in June and· once in July (Appendix
Report 3-0-1).
2.1.3.2 Hydraulic Zones
In order to further evaluate the relative biological importance of the
DFH sites during the open water season, each site was subdivided into
zones based on the hydraulic conditions present and on the water source.
The zones were then s~mpled ·independently so that statistical
comparisons of fish distribution and abundance could be made among zones
in order to determine· the relative importance of each zone to each
species. Changes in the spatial distribution and the surface area of
hydraulic zones over time were correlated with corresponding changes in
the discharge of the mainstem Susitna, tributary or ground water input.
' \ '
The methods, results, and discussion of this aspect of the study are
presented in Vo 1 ume 4, ·Part I. Nine samp 1 i ng zones were defined (Tab 1 e
3-2-2). The number of hydraulic zones varied at each site depending on
the mainstem stage levels, as well as on tributary and slough flows.
The distribution of zones at a hypothetical site at three different
levels of mainstem discharge is shown in Figure 3-2-3. A further
discussion of the hydraulic zone concept is contained in Vol. 4, Part
II, Section 2.2. Various habitat parameters were measured in each zone
20
Table 3-2-2. Description of habitat zones sampled at Designated Fish
Habitat Sites on the Susitna River, June through
September, 1982.
ZONE
CODE
1
2
3
4
5
6
7
8
9
DESCRIPTION
Areas with a tributary or groundwater water. source, which are no!,
influenced by mainstem stage;, and which usually have significant
surface water velocity.
Areas with ~.tributary or 9roundwater water source, which have no
appreciablel'!' surface water velocity as a result of a hydraulic
barrier created at the_ mouth of a tributary or slough by mainstem
stage.
Areas of significant surface water velocities, primarily
influenced by mainstem, where tributary or slough water mixes with
the mainstem water.
Areas of significant surface water velocities, which are located
in a slough or side channel above a tributary confluence (or in a
slough or side channel where no tributary is present); when the
slough head is open.
Areas of significant water surface velocities, which are located
in slough or side channel below a tributary confluence, when the
slough head is open.
Backwater areas with no appreciable surface water velociti~s
resulting from a hydraulic barrier created by mainstem stage,
which occur in a slough or side channel above a tributary
confluence (or in a slough or side channel.· where no tributary
is present), when the head of the slough is open.
Backwater areas with no appreciable surface water velocities
resulting from a hydraulic barrier created by mains tern stage,
which occur in a slough or side channel below a tributary
confluence, when the head of the slough is open.
Back~ater areas consisting of mainstem eddies.
A pool with no appreciable surface water surface velocities, which
is created by a geomorphological feature of a free-flowing zone or
from a hydraulic barrier created by a tributary; not created as a
result of mainstem stage.
N 11 Significant 11 and "appreciable" surface water velocities mean .a
velocity of at least 0.5 ft/sec. However, there are site-specific
exceptions to this, based on local morphology.
21
~MAINSTEM-
"'-s Iough
-3 Mouth ~ MAINSTEM-
~Slough
-3 Mout.h ~ MA.INSTEM-
[I}MAINSTEM BACKWATER AREA
-FREE-FLOWING WATER
H·IGH MAINSTEM
01 SCHARGE
MEDIUM MAINSTEM
DISCHARGE
LOW MAINSTEM
DISCHARGE
-··~· ..... -.,. ···.:;,.-.·:..··
~'-Slough
Head (Closed)
Figure 3-2-3. Hypothetical slough with associated tributary showing
hydraulic zones present at three mainstem discharges.
22
in order to relate fish distribution to habitat variables. The methods,
results, and discussion of this phas.e of the study are presented in
Volume 4, Part II.
2.1.3.3 Biological Sampling
Biological sampling at the 17 DFH sites was conducted in two, three, or
four of the hydraulic zones present at each site, depending upon condi-
tions. Fisheries sampling gear was classified standard or opportunistic
gear. Standard gear consisted of minnow traps, each baited with a
tablespoon of salmon roe, and trot lines consisting of six #4 hooks
baited with salmon roe, fish flesh and bacon. Generally, five to ten
minnow traps were set in each hydraulic zone sampled for a period of
three to four hours. (Results of a 24 hour exper·irnent to determine an
adequate length of time to fish minnow traps are contained in Appendix
Report 3-E-1). Also, one trot line was set for 24 hours in each zone
sampled with minnow traps.
Opportunistic gear consisted of beach seines, backpack electrofishing
units, dip nets, hoop nets, fish traps, variable mesh gill nets and hook
and line and was used to sample the same zones as standard gear whenever
conditions permitted their use. Beach seines and el ectrofi shi ng gear
were the most frequently utilized opportunistic gear (Plate 3-2-3 and
3-2-4). Information collected by opportunistic gear was less reprodu-
cible than that collected by standard gear, but was useful in observing
the relative distribution of fish species not collected by minnow traps
or trot lines. Opportunistic gear was essential for collecting chum and
23
I
k ~
Plate 3-2-3. Beach seining along a gravel bar at Indian River-Helicopter Site 1 (TRM 2.7).
N
U1
Plate 3-2-4, Electrofishing with a backpack electroshocker at Slough 8 (RM 113.6).
sockeye salmon fry and juvenile grayling, round whitefish and rainbow
trout. Techniques used to deploy biological sampling gear and methods
of data collection can be found in the Procedures Manual (ADF&G, 1982d).
Fish that were collected were anesthetized with Tricaine Methane-
sulfonate (MS-222) when necessary to minimize physi ol ogi ca 1 stress due
to handling while collecting length and scales. All specimens were
identified to species. Burbot and cotti ds were measured for tota 1
length in millimeters (mm); 'all other resident species were measured for
fork length. A subsample of juvenile salmon, taken in accordance with
the Procedures Manual, were measured to total length. Adult and
juvenile resident specimens greater than 200 ,mm in fork length were
tagged with a Flay tag below the dorsal fin (Plate 3-2-5). Otoliths
were taken from burbot mortalities for age ana1ysis. Resident species
mortalities were necropsied to determine sex and relative sexual
maturity (Plate 3-2-6).
Occasional juvenile anadromous and juvenile resident fish of question-
able identity were preserved in 10% formalin for later laboratory
identification. Certain large juvenile chinook and coho salmon were
preserved for later scale analysis to help determine the length at which
age classes were separate,d. Age <;lasses for juvenile salmon were
determined from scale analysis and from length frequency of the pooled
fish from the fish di strub'iti on study and from the downstream migrant
trap.
In addition, each bi ol ogi st recorded field observations concerning the
predominant hydraulic and habitat conditions and major biological
26
. -~
"•'t:"<;
(I"'' ~Y;;,} : •
Plate 3-2-5, Tagging burbot with Floy anchor tags at Whitefish Slough (RM 78.7).
Plate 3-2-6. Necropsying a burbot to determine its sex and relative
maturity at Portage Creek mouth (RM 148.8).
28
findings encountered at each sampling site. The entire study site was
mapped on aerial photographs and staff gage readings from each zone were
recorded {see Vol. 4, Part I, Methods). Ground photographs were taken
of each zone boundary each sampling trip.
Other data was obtained at DFH sites by the boat electrofishing study,
which also sampled these sites twice monthly.' Most of that effort
occurred in the mixing zone or in the mainstem backwater zone. Addi-
tion ally, data call ected on juvenile anadromous species composition,
length, and age were correlated with the data from the downstream
migrant trap {located at RM 103.0} to assist in determining timing of
fish movements.
2.1.3.4 Winter Season Methods
Thirty two sites, including 15 of 17 DFH sites, were sampled during
February, March, and April, 1982 (Appendix Tables 3-A-4 and 3-A-5}. The
sites ranged from Mid Kroto Slough {RM 36.3) to Portage Creek (RM
148.8}. The winter program was not designed to differentiate hydraulic
zones within a habitat location. Deployment of winter sampling gear was
limited to areas at each site that could be sampled under existing ice
conditions. Minnow traps, trotlines~ and varfable mesh gillnets were
deployed at each habitat location in areas of open water or through
access holes made through the ice with gas powered augers (Plate 3-2-7).
Access to sampling sites was accomplished by snow machines and
helicopters.
29
Checking an under-ice gill net
in the mainstem Susitna River.
Plate 3-2-7# Winter .sampling techniques.
30
Setting a variable mesh
gill net in an open lead.
Burbot caught on a
trotline.
2.1.4 Other Methods
Crews operating fishwheels at the Yentna, Sunshine, Talkeetna, and Curry
stations for the purpose of capturing adult anadromous fish also
collected data on adult resident fish catches of the fishwheels. They
recorded daily catches and also tagged and measured adult residents
captured when time allowed from their primary duties. An table of
fishwheel effort by bimonthly sampling period for each location is given
in Appendix Table 3-A-6.
Additionally, hook and line, trotlines, and hoop nets were used at a few
selected sites in an attempt to obtain burbot and rainbow trout for
radio tagging. Catch and biological data were recorded during these
incidental efforts. All adult residents in good condition were tagged.
2.2 Emergence and Outmigration Studies
Minnow traps, beach seines, and backpack electrofishing units were
utilized as collection techniques during the 1981-82 resident and
juvenile anadromous studies program. These techniques did not
adequately assess the times of emergence and outmigration of juvenile
anadromous fishes of the Susitna River. Additional techniques were
developed during 1982 to provide a more detailed study of emergence and
the downstream movements of juveniles of selected species and the
factors affecting their distribution.
31
Surveys of selected spawning areas were conducted monthly during March,
April, and May of 1982 to collect baseline data on the timing of
emergence o( juveni1e salmon. Utilizing snow machines and helicopters
to gain access to the study areas, eggs and alevins were collected by
dip nets and spade shovels.
A downstream migrant trap employing an inclined plane was developed to
capture outmigrating resident and juvenile anadromous fishes in the
Sus itna River. The trap was constructed during the spring of 1982 and
was operated from June 18 through October 12, except for short periods
of down time caused by manpower limitati'ons', excessive debris loads, or
the need to conduct trap modifications or rep•irs. The trap was
deployed above the confluence of the Chulitna River to 1 imit the
collection of fish to only upper Susitn(l River stocks. These stocks of
fish would most lik.ely.be affected by changes in the river conditions
resulting from the proposed hyclro.electri c development. A site at the
Talkeetna base camp (RM 103.0) was selected for trap operation because
of its single channel morphology, optimum depth and velocity, and its
close proximity to logistical support (Figure 3-2-4).
The downstream migrant trap consisted of two polyethylene plastic
modular pontoons serving as flotation for a welded steel lattice frame
in which was mounted the inclined plane and livebox (Plate 3-2-8). The
stee 1 infrastructure was covered by a two-feet wide plywood deck
surrounding a five by ten feet center opening for suspension of the
inclined plane and livebox. A three-feet high safety railing was
attached to the rear of the trap. The entire trap structure measured 10
feet by 17 feet.
32
, .
DOWNSTREAM MIGRANT
TRAP LOCATION
Figure 3-2-4. Map showing the location of the site on the Susitna River
where the downstream migrant trap was operated, June 18
to October 12, 1982.
33
Plate 3-2-8.
,_::._..-;... ... ·4 -:-----
... _ ... ----··
\, ..... . . . -~ .. ~
--..
. ... ·-
.·---6
·-
Downstream migrant trap fishing at its mainstem Susitna River location at River mile 103.0,
1982.
' .,
1
The inclined plane was eight feet long with an entrance opening
measuring 4.5 feet square and was covered by one-quarter inch galvanized
hardware cloth on the sides and bottom. Hand crank winches were used to
adjust the fishing depth and to raise the inclined plane for cleaning.
The livebox was covered by one-eighth inch hardware cloth on the sides
and bottom and was removable.from the trap structure to accommodate
cleaning and retrieval of captured fish. A more detailed description of
trap design and construction, techniques utilized tc determine optimum
trap placement, and vertical and horizontal fish distribution and
diurnal movements are provided in Appendix Report 3-F-1.
The stationary inclined plane trap requires a river velocity of at least
1.0 feet per second for successful operation. The mesh of the inclined
plane allows the major portion of the sampled water column to pass
through the screen while ·retaining the fish and the remaining water
which pass over a baffle and into the livebox (Plate 3~2-9). The trap
was secured via a cable and rope attached to large trees upstream of the
trap and was held out from the bank by a boom log attached to the trap
and shore. Distance from shore was adjustable by movement of the shore
end of the bornn log.
Captured
(MS-222).
fish were anesthetized using Tricane methane-sulfonate
Species, total length, and fate were recorded for each fish.
All fish were retained until anesthetic recovery was complete and then
released downstream of the trap to prevent recapture.
35
Sample of the downstream migrant
trap catch of Age o+ salmon:
Chinook, Coho, Chum, and Sockeye
salmon.
Winching up the inclined
plane of the downstream
migrant trap to clean the
screen surfaces .
IMETRI C 'I 21 31 41 51 61 111111 11 1 JIIIJJJlJilll.liJllllLUlJ IJJliJllill ll ll lliiUJ
: .... :'":~·-:-:-·~:~;-:-.-.-;~ ................. -~--_ ........ ·.::~
........ ·::::':;
Winch assembly, baffle,
and livebox on the down-
stream migrant trap.
Plate 3-2-9, Downstream migrant trap operation and sample catch, 1982.
36
Trap check intervals were determined by catch rates and debris levels.
Periods of high catch rates or high debris loads required a shortened
check interval to reduce mortalities associated with livebox turbulence
and to maintain optimum trap fishing conditions.
Turbidity readings were recorded daily beginning August 14 using an HF
Instruments turbidometer. Staff gauge readings were recorded daily and
water temperatures were obtained from a Ryan thermograph located at the
Talkeetna camp.
The date fished, effort, catch by species, trap depth, distance from
shore, and live box mortalities were recorded daily. Species, age,
total length in millimeters (mm), and fate were also recorded. Scales
were co 11 ected from a subsamp 1 e of the captured fish ,for comparison to
length frequency distribution to determine age class composition by
species.
Additional data on juvenile anadromous and resident fishes was collected
by Designated Fish Habitat site surveys and mobile boat-mounted
electrofishing units. Refer to report sections 2.1.1 and 2.1.3 for a
description of the methods used in these mobile gear surveys.
2.3 Food Habits of Juvenile Salmon
2.3.1 Field sampling
Field investigations for the Food Habits Study we're conducted at five
slough and two clear water tributaries of the Susitna River (Table
37
3-2-3). This was a pi 1 ot study begun in early Aug.ust when funds became
available. All sites were between RM 125.3 and R~1 142.0. These sites
were selected because they were considered to be representative of the
major habitat types, and because they were expected to have sizeable
populations of juvenile salmon. Detailed descriptions of these sloughs
and tributaries are presented in Appendix 4-F of Volume 4.
Collections were made every other week in August and September.
Juvenile salmon were collected by electroshocking, minnow trap, and
seines. Seining for juveniles was not very successful and was used only
during the August sampling trips. The use of minnow traps in sloughs
was discontinued in September because electroshocking was found to be a
more productive and efficient collecting method in all sloughs sampled.
Minnow traps, however, were the most successful method in Fourth of July
Creek, and were also effective in Indian River. Traps were used during
both August and Septemb~r ~t both tr'ibutary sites.
The minnow traps used had· a mesh size of 6.4 mm {1/4 ·inch), and were
baited with salmon eggs held in a perforated plastic bottle. They were
us~ally placed near beaver dams, brush piles, cut banks, and large rocks
which provide cover for juveniles {Plate 3-2-10). These traps were
fished for three to six hours, usually from mid-morning to early
afternoon. Electroshocking was done with backpack electroshockers in
areas similar t(} where the minnow traps were set. Both Coffelt and
Smith-Root shocker models were used. Electroshocking was ineffective at
Fourth of July Creek due to low conductivity.
38
Table 3-2-3. Six DFH sites on the Susitna River and the dates on which
they were sampled by the Food Habits Investigations Group,
August to September, 1982.
DFH Sites River Mile Miles Sameled Samelins Dates
Slough 8A 125.3 Mouth to 0.5 8/6,25 ... 9/7 ,22
Upstream
Slough 9 129.2 Mouth to 0.5 9/7
Upstream
4th July Creek . 131.1 Mouth to 0.25 8/5,28 9/8,22
Upstream
Slough 11 135.3 Mouth to 0.5 8/3,24 9/5,20
Upstream
Indian River 138.6 Mouth to 0.3 8/8,29 9/9,23
Upstream
Slough 20 140.1 Entire 0.5 8/4,26 9/6,21
Slough 21 142.0 Origin to 0.6 8/7,27 9/8,21
Downstream
39
Plate 3-2-10. Minnow trap set in a typical juvenile salmon rearing
habitat at Slough 21 (RM 142.5).
40
Fish collected were immediately preserved in 70% ethanol. Observation
of the first several fish captured indicated that they did not
regurgitate their stomach contents when preserved by this method. The I .,
body wall of large specimens (greater than 80mm) was opened to insure
rapid preservation of the stomach contents. The goal was to collect 15
individuals of each species of juvenile salmon present at each site.
\ \
Generally it was not possible to collect this many of each species in
the time alloted for sampli~g each site. If more than 15 individuals of
I
any species were collected they were released.
Invertebrate samples were collected by using a kick screen and a set
drift net. The kick screen consisted of a 63 x 83 em sheet of 11 noseeum 11
netting, with approximately 500 mu mesh (Plate 3-2-11). This screen was
stretched between two dowels, and was held by hand in the stream. The
substrate was disturbed in an approximately two meter square area
immediately upstream of the net, and the dislodged invertebrates were
carried by the current downstream into the net. In areas with little or
no current, the screen was pushed through the sampling area. Kick
screen collections of invertebrates were carried out near areas where
fish had been found at each site. Usually, two collections were made at
each site on each sampling date.
The drift net used for collecting invertebrates had a 30 x 50 em
opening, and was 99.1 em long with a Wisconsin type plankton bucket
attached to the downstream end. The netting was 500 mu nylon mesh. The
net was placed at the base of a riffle downstream of an area which would
not be disturbed by our other sampling activities and was held in place
41
Plate 3-2-11, Kick ~creen used for sampling invertebrates.
42
by two steel stakes (Plate 3-2-12). Care was taken that the net was set
in water shallow enough to allow at least eight em of its opening to be
above the water surface. The net was left in place for a minimum of
three hours. Invertebrate samples were preserved in 70% ethanol and
taken to the lab in Anchorage for sorting and identification.
2.3.2 Laboratory Methods
Fish stomachs were removed by making one cut just posterior to the
esophagus, and one just anterior to the pyloric cecae. The contents
were removed, and examined under a dissection microscope. Only those
invertebrates which had both a head and part of their body were counted.
Enumeration was done in this way to prevent a:ny numerical bias being
given to those invertebrates which could be recognized by the head
alone. However, chironomid larvae were counted even if only their head
remained because they are soft-bodied, and all but their head capsule is
rapidly digested. It was felt that the chironomid larvae count would
not be representative of the number of chironomid larvae consumed unless
the count was done in this manner.
Invertebrate kick screen and drift samples were sorted under a dis-
section microscope (Plate 3-2-13). Aquatic invertebrates from both the
stomach contents and invertebrate samples were identified to order or
family. Terrestrial invertebrates which have no aquatic life stage were
identified to order. Major keys used for identification were: Borrer
and Delong (1971), Merrit and Cummins (1978), and Pennak (1978). At the
43
Plate 3-2-12. Invertebrate sampling with a stream drift net at Slough 21 (RM 142.5).
Plate 3-2-13 , Sorting field samples of invertebrates in the lab with
the aid of a dissecting scope.
45
time this report was written, manpower limitations did not allow the
examination of all collections made during the 1982 season. Kick screen
samples from our early August and late September samples will be
examined as time permits.
2.3.3 Analytical Methods
Abundance of each prey type in the environment was compared to its
abundance in the stomachs using Strauss's linear electivity index
(Strauss 1979). The linear index is simply the difference between two
proportions (r;-Pi) where ri is the percent· of prey type i in the
stomachs, and P; is the percent of. that prey type in the environment.
The linear index ranges from -1.0 to +1.0. Positive values indicate
that the proportion of the prey type in the stomach is higher than in
the environment (positive selection). Negative values indicate that the
prey is either inaccessible or is avoided by the fish (negative
selection}. Values near zero indicate random selection of prey from the
environment. Confidence limits for the linear index were calculated
using the formula given by Strauss (Strauss 1979).
Rough comparisons of invertebrate populations between sites were also
made. Invertebrate samples were not quantitative so direct comparisons
of numbers at each site could not be made. ~nalysis was done instead by
comparing the proportion of the total sample made up by each inverte-
brate type at each site using chi-square analysis (Fleiss 1981).
Contributions of prey types to the diet of each of the salmon species
were also compared using chi-square analysis.
46
3. RESULTS
3.1 Distribution and Abundance Studies
3.1.1 Resident Fish Species
Eleven species of resident fish were captured during 1982 field studies
conducted below Devil Canyon (RM 150.2). Individuals of all these
species were also captured during 1981 ADF&G Studi~s (ADF&G 198lc). The
Bering Cisco (Coregonus laurettae Bean) was categorized as a resident
fish in ADF&G (1981c) but now is discussed with the adult anadromous
species in Volume 2.
One northern pike (Esox lucius L.) was captured in the Yentna River (RM
27.5, TRM 6.0) in a fishwheel on August 19, 1982. In 1981, one adult
northern pike was also captured near the Yentna River confluence (ADF&G
1981c). Apparently the fish are expanding their range or simply wander-
ing downriver from several lakes in the Yentna River drainage where they
were illegally transplanted during the 1950's.
The results of 1982 field studies are detailed for the other resident
species in the following sections. Habitat relationships of these
species are discussed in Volume 4, Part II. Age, length, and sex data
for all resident species are contained in Appendix Report 3-G-1.
47
3. 1. 1. 1 Rainbow Trout
Distribution and Relative Abundance
Eight rainbow trout (Salmo gairdneri Richardson} were captured during
the ice-covere_d season from February through April (Appendix Table
3-A-7). Four of these fish were captured in the mainstem below the
Chulitna River confluence, while the other four were captured at the
Deshka River (RM 40.6, TRM 3.5), Goose Creek 1 (RM 72.0}, Slough 10 (RM
133.8} and Slough 22 (RM 144~3).
Another 307 rainbow trout were captured between May and October (Table
3-3-1). At the DFH sites, .a total of 207 rainbow trout were captured at
16 of the 17 sites (Appendix Tables 3-A·B and 3-A-9). The 4th of July
Creek DFH site had the largest number of rainbow trout sampled with 43
captured. ·Other DFH sites at which more than 20 rainbow trout were
captured included Whiskers Creek and Slough, Slough 8A, and Indian
River. Whitefish Slough was the only DFH site at which no rainbow trout
were caught. Other OFH sites at which only one or two rainbow trout
were captured included Rabideux Creek and Slough, Slough 19, Slough 21,
· and Portage Creek.
Rainbow trout were also captured at SFH tributary and mainstem sites
both above and below the Chulitna River confluence (Appendix Tables
3-A-10 and 3-A-11). Tributary sites below the confluence at which
rainbow trout were captured included the mouths of Little Willow Creek
(RM 50.5) and the Talkeetna River (RM 97.0). Above the Chulitna River
48
.;:.
'-0
Table 3-3-1
Study Site Type
DFH Sites
SFH Sites
Rainbow trout catch on the Susitna River between Cook Inlet and Devil Canyon by study site
type, May to October, 1982.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL ---
15 26 44 16 4 8 10 27 53 4 207
2 13 14 2 2 2 3 13 3 1 55
Downstream migrant trap 1 0 3 1 0 1 0 0 6
Fishwheel sites 5 10 4 0 2 2 . 13 3 39
TOTAL 17 44 69 22 9 13 15 54 59 5 307
-no sample
confluence, rainbow trout were captured at five tributary sites and five
slough sites. Six rainbow trout were captured in the ma·instem by the
downstream migrant trap and 39 by fishwheels (Table 3-3-1). Thirty-
sev~n of the rainbow trout captu~ed in fishwheels were captured at the
Sunshine (RM 79.0) and Cu~ry (120.0) stations (Appendix Table 3-A-12).
Movement andMigration
Radiotelemetry was used to study winter movements. of adult r~inbow
troUt. The five rainbow trout that were radio tagged were capt,ured,
tagged and released between October 5 •nd 15, 1981. Four of the rainbow
trout were ca~turi:!d at RM 76.3, the other rainbow trout at RM 84.1. The
five fish tagged ranged frdm 350 mm to 455 mm in fork length. The fish
were then radio tfaC:ketl until Apr'il 6, primat"Lly with. fixed wing air-
craft.
During the earliest aerial tracking flight on october 15, alL five
rainbow trout we~e located. two of the raihbbws showed no movement, one
moved upstteam 0.5 miles, and one fuoved downstream 5.6 miles from ~here
it was tagged and released (Figure 3'-3-1). One rainbow was still in the
live box and was released later that day.
One radio tagged rainbow was ·not located on subsequent flights after
January 6. Rainbow trout 750-1 was last located during December 28 on
the Susitna River at RM 62.5. The fish at this time was in the same
vicinity as rainbow tr()lit 750-2.
50
(.J1 .......
w
_J
90
80
70
~ 60
0::
w
>
0:::
50
40
·--•, .......... ....
, ..............
\ ....
\ '·., \ .
\ • ' ·' ...
.... --·----·-----....
I
\
\
\
\
\
\
\
\
\
.{750-1 \
-·-·-· .... ·-·-·-·-',
\ .. \ . ·,, \ ·--·----\ '· \ -------
\ ' ---·---·---~·-'----_____ .. '·~}
•,
760-2
'•--··---· 50 2 ------• --..... - - - - -~ - --· 7 -
0+-------~------~--------~------~------~--------~------~------~
SEPT OCT NOV DEC JAN
1981
.FEB MAR
1982
APR MAY
Figure 3-3-1. Movement of five·radio tagged rainbow trout in the Susitna River, October 1981 to April 1982.
Four of the rainbow trout were located on an aerial tracking flight
during February 10. Two of the rainbow trout, 750-3 and 760-2 were
located in the east channel of the Sqsitna between the mouth of Little
Willow Creek (RM 50.5) and the mouth of Goose Creek (RM 72.0). Rainbow
trout 750-2 was located in a side channel of the Susitna River at RM
61.0.
Three of the four rainbow trout were located on subsequent flights after
February 10 but none moved over 0.5 miles after this date. The maximum
movement by any of the five rainbow trout was recorded for rainbow trout
750.,.3; it moved 23.3 miles downstre-am in a maximum of 126 days. Three
of the radio tagged rainbow trout moved upstream between October and
April. The farthest upstream movement was evidenced by rainbow trout
740-3 which moved 4.0 miles in a maximlJm of six days.
Recapture of three of the radio tagged rainbow trout was attempted in
February and March as the radio tags approached their battery expiration
dates. However, none of the radio tagged rainbow trout were recaptured
during these trips.
Ice augering in the vicinity of rainbow trout 750-3 during mid-February
at RM 53.0 indicated that this fish was dead. There was no water in the
-immediate vicinity of the maximum signal strength of the radio tag.
Three adult nontagged resident fish, however, were captured by trotlines
set nearby. One Arctic grayling, one rainbow trout and one burbot were
captured using 8.0 units of trotline effort.
52
One rainbow trout (tag number 750-2) was located in a side channel of
the Susitna River opposite the mouth of Kashwitna River (RM 61.0) during
February. The fish would move approximately 300 feet after ice augering
in the suspected vicinity of the fish. During the March recapture
attempt, no movement was detected. One untagged rainbow adult was
captured in the vicinity of rainbow trout 750-2 using 3.0 units of
gillnet effort and 4.3 units of trotline effort.
During March, rainbow trout 760-2 was in the east channel of the Susitna
River at RM 67 .5. Ice augering in the vicinity of this radio tagged
fish did not indicate if the fish was alive or dead;. no movement was
detected. Two untagged rainbow trout were captured in the vicinity in
17.3 gear units of trotline effort.
Rainbow trout 740-3 was captured on May 27, 1982 by a sports fisherman
at the mouth of Montana Creek (RM 77.0). He reported that the fish was
healthy and vigorous, and that the incision had healed. There was no
connective tissue formed on the surface area of the radio tag as a ' "~·.
result of the fish rejecting the tag. Connective tissue has been
reported to encase surgically implanted radio tags during other radio
telemetry studies (Carl Burger, USFWS,. pers. Comm.).
Movements of adu 1t rainbow trout were also studied with a tag arid
recapture program. During 1982, 195 rainbow trout were tagged and a
total of 32 recoveries of 29 different rainbow trout were made (Appendix
Table 3-A-13). Twelve of the recoveries made were fish tagged in 1981
and the overall.recovery rate of fish tagged in 1981 was 5.3 percent (11
53
of 206, one fish was recaptured twice)~ The recovery rate of rainbow
trout tagged in 1982 was 9.2 percent (18 of 195}.
Apparent movements of tagged rainbows were limited. Only three of the
11 rai nb.ow trout tagged in 1981 and recovered i.n 1982 were captured more
than five m"iles from th€ir tagging location. Similarly, less than 20
percent ( 3 fish) of the 18 rainbows tagged and recovered in 1982 moved
more than five miles. Twenty-one of the 32 recoveries made in 1982
showed movements of one mi 1 e or less. The maximum movement was made by
a rainbow trout tagged at Birch Creek and Slough on May 25 ~ 1982 and
then recovered on June 2,. 1982 by an angler at Fish Creek, a tributary
of the Talkeetna River 17. 3. river miles upstream.
Spawning
No rainbow trout were obs.erved spawning during the 1982 field season in
the mainstem Susitna River. Three male rainbow trout captured in late
·May at Whiskers Creek and Slough, however, discharged milt when their
abdomens were pa 1 pated. The fork 1 ength of these fish ranged from
280"':3e~·mm. Age-length frequency data indicate that the 280 mm fish was
four or five years old, while the 385 mm male was six years old (Appe-
ndix Report 3-G-1). One other. ripe male was captured at Indian River on
June 28th.
54
3.1.1.2 Arctic Grayling
Distribution and Relative Abundance
Winter sampling efforts from February through April, 1982 resulted in
the capture of two Arctic grayling (Thymallus arcticus Pallas). One
adult was captured in late February at a mainstem site (RM 53.5) by
trotline and one juvenile was minnow trapped in April at Cache Creek.
A total of 1,023 juvenile (fork length under 200 mm) and adult Arctic
grayling were captured during 1982 summer field operations on the
Susitna River downstream of Devil Canyon (Table 3-3-2). Over 80 percent
(821 fish), of the Arctic grayling captured in summer were captured by
boat electrofishing at DFH and SFH sites.
Five hundred and twenty-two (51.0%) of the Arctic grayling captured
during the summer were caught at DFH sites (Table 3-3-2). Most of these
fish were captured by electrofishing, and beach seining; other ~ampling
methods (trotlines, gillnets, dipnet, and angling) captured only 38 of
the 522 (Appendix Tables 3-A-14 and 3-A-15). The highest catch of
Arctic grayling at DFH sites was recorded at Lane Creek and Slough 8
where 117 fish were captured. Other DFH sites where relatively large
catches were made included Whiskers Creek and Slough, Fourth of July
Creek, Indian River, Slough 20, and Portage Creek. Sunshine Creek and
Side channel was the only DFH site where no Arctic grayling were caught.
Arctic grayling were also captured at ten other tributaries and sloughs
above the Chulitna River confluence and at six other tributaries and
55
U1
0'
Table 3-3-2
Study Site Type
DFH Sites
SFH Sites
Arctic grayling catch on the Susitna River between Cook Inlet and bevil Canyon by study site
type, May to October, 1982.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16"-30 1-15 16--31 1-15 16-31 1~15 16-30 1-15 TOTAL
12 27 126 35 47 63 50 86 70 6 522
5 55 128 8 26 38 51 78 22 411
Downstream migrant trap I 8 1 4 0 0 1 0 15
Fishwheel sites 16 6 2 2 2 0 13 34 75
TOTAL 17 98 261 53 76 107 101 177 127 6 1023
-no sample
sloughs below the confluence (Appendix Tables 3-A-16 and 3-A-17). A
total of 193 Arctic grayling were captured at· these SFH tributary or
slough sites; electrofishing also captured 216 Arctic grayling at SFH
mainstem sites between Cook Inlet and Devil Canyon. The hig'hest catch
of Arctic grayling at SFH sites was recorded at Jack Long Creek {RM
144.5) where 58 Arctic grayling were caught. ·Other SFH sites where
relatively large catches were made in 1982 included Skull Creek (RM
124.7), Slough 15 (RM 137.2), and a mainstem site at RM 150.1. The
farthest downstream site where Arctic grayling were caught was RM 31.1,
and RM 150.1 was the farthest upstream site for the reach of river below
Devil Canyon.
In addition to the Arctic grayling captured by mobile gear at DFH and
SFH sites, fish were captured by fishwheels and a downstream migrant
trap. Seventy-five adult fish were captured by fishwheels (Appendix
Table 3-A-18). Fifty of these fish were captured at Sunshine (RM 79.0),
ten were caught at Talkeetna (RM 103.0) and 15 at Curry (RM 120.0). The
downstream migrant trap at RM 103.0 captured 14 juveniles (fork length
under 200 mm) and one adult Arctic grayling during 1982. The maximum
seasonal catch at the trap was recorded during early July when eight
Arctic grayling were captured.
The maximum seasonal catch of Arctic grayling by all methods was record-
ed in late June when 261 fish were captured. Relatively high catches
were also recorded in September.
Four hundred and eighty-three (47.2%) of the 1,023 Arctic grayling
captured downstream of Devil Canyon were juveniles. Three hundred and
57
twenty-seven (67.7%) of these juveniles were captured upstream of the
Chulitna River confluence. Boat el ectrofi shi ng captured the highest
number, 347 (71.8%), of juveniles in comparison to other sampling
methods.
In the reach of river below Devil Canyon juvenile Arctic grayling were
caught at sites ranging from RM35~0 to RM 150.1. Seasonally, high
:catches of juveniles were also recorded during June and September.
Movement and Migration
Seven hundred and forty-eight Arctic grayling. were Flay anchor tagged in
the. Su.sitna Ri.ver below Devil Canyon between 1980 and 1982 (447 in 1982)
during a tag and recapture program. Forty eight Arctic grayling have
been recaptured with 45 (94%) of those occurring during 1982 (ADF&G
1981; Appendix Table 3-A-19). Of tkle 45 fish recaptured in 1982, ten
were recoveries of fish tagged in 1981. The recovery rate for Arctic
grayling tagged in 1981 was 3.3 percent (10 of 301} while 7.8 percent
(35 of 447) of the fish tagged in 1982 were recaptured.
The Arctic grayling recaptured in 1982 were at large from two days to
over a year. The maximum upstream movement was 13.3 miles and the
maximum downstream movement was 10.0 miles. No movement was recorded
for 30 (66.7%) of the 45 recaptured fish. The maximum movement recorded
for any recaptured Arctic grayling in the Susitna River below Devil
Canyon was in 1981, it moved 32.5 miles (ADF&G 1981c).
58
Spawning
No Arctic grayling spawning was observed during the 1982 field season in
the mainstem Susitna River between Cook Inlet and Devil Canyon. One
female, 362 mm in fork length and six years old, captured in the main-
stem Susitna River at RM 60.5 during late May, discharged eggs when its
abdomen was palpated (Appendix Table 3-A-20). One ripe male was also
captured during late May in the mainstem Susitna River (RM 77.5) Spent
Arctic grayling were captured at the mouth of the Talkeetna River (RM
97.5) on June 5, Lane Creek on June 6 and Indian River on June 28.
The fork lengths of the two ripe and three spent Arctic grayling ranged
from 352 mm to 400 mm. Analysis of scales from Arctic grayling indicate
that they were predominately six and seven year old fish (Appendix
Report 3-G-1).
3 .1.1. 3 Burbot
Distribution and Relative Abundance
During 1982 field studies, a total of 452 adult burbot (Lata lota L.)
were captured in the Susitna River downstream of Devil Canyon. Winter
sampling during February through April captured 32 burbot with the
remaining 420 fish taken during May through October (Appendix Table
3-A-21, Table 3-3-3). Trotlines and electrofishing were the most
effective means of catching burbot.
59
0'1
0
Table 3-3-3
Study Site Type
DFH Sites
SFH Sites
Burbot catch on the Susitna River between Cook Inlet and Devil Canyon by study site type. May
to October, 1982.
MAY JUNE JUNE JULY JULY · AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL
0 14 30 . 13 22 18 19 33 19 3 171
2 5 14 24 23 8 26 29 26 11 168
Downstream migrant trap 18 3 21 5 2 9 12 0 70
Fishwheel sites 0 0 0 2 1 2 3 3 11
TOTAL 2 19 62 40 68 32 49 74 60 14 420
-no sample
Burbot were caught at all 17 DFH sites during 1982 (Appendix Tables
3-A-22 and 3-A-23'. The most productive of the OFH sites for adults
were Goose Creek 2 and Side Channel, Rabideux Creek and Slough, Sunshine
Creek and Side Channel, Birch Creek and Slough, Slough 6A, and Slough
21. Less than five burbot were captured at the mouth of 4th of July
Creek, Slough 11, Indian River and Slough 20.
Burbot were also captured at a number of SFH sites both above and below
the Chulitna River confluence (Appendix Tables 3-A~24 and 3-A-25). Most
of the SFH sites where burbot were captured were in the mainstem.
Fishwheel catches of burbot were 1 imited but at least one burbot was
caught at all of the fishwheel stations except Talkeetna (RM 103.0)
(Appendix Table 3-A-26).
In addition to the adult catch, a total of 106 burbot juveniles (total
length under 200. mm) were captured downstream of Devil Canyon during
1982 sampling. Seventy of these juveniles were caught in the downstream
migrant trap (RM 103.0) with the remainder taken by minnow traps, beach
seine, or electrofishing.
Movement and Migration
Little data on summer movements · of bu rbot have been co 11 ected from a
tagging program because tag recoveries have been low. During 1982
sampling, 265 burbot were tagged and three tag recoveries were made
(Appendix Table 3-A-27). Movements represented by the tag recoveries of
burbot tagged in 1982 were 0-1.6 miles upstream over a 5-69 day period.
61
One burbot was also recaptured in 1982 out of 240 tagged during 1981.
This bu rbot was tagged September 12, 1981 and recovered 68.9 miles
upstream one year later on September 14, 1982.
In addition, five burbot were captured, radio tagged and released
between October 3 and October 6, 1981 in an attempt to study winter
movements. Two of the burbot were captured at RM 76.3 and three at RM
84.1 The five fish tagged ranged from 575 mm to 835 mm in total length.
The fish were radio tracked until April 6 primarily with fixed wing
aircraft. During the earliest aerial tracking flight on October 15, all
five burbot were located. Three of the burbot had not moved from the
site of their capture while the other two moved downstream 0.6 and 1.3
miles respectively (Figure 3-.3-2). Burbot 760-3 was not located after
December 4. Th~ other four burbot were located until March 22. Only
burbot 770-2 was 1 ocated during the 1 ast monitoring flight on April 6.
The maximum movement and rate of movement was recorded for the burbot
760-1~ This burbot was released at RM 76.3 on October 5 and located at
RM 16.0 on February 18. It moved 57.2 miles downstream between December
4 and January 15 .at a minimum rate of 1.5 miles per day. This fish
moved upstream three miles on the subsequent trip. Three of the other
·four radio tagged b.urbot also made upstream movements between October
and April. Themaximum upstream movement was made by burbot 770-2 which
moved 5.5 miles in a maximum of 48 days.
Recapture of two radio taggedburbot was attempted twice in March as the
radio tags approached their known battery 1 ife. Initially aeria 1
62
0"1 w
100
80
w 60
_J
:E
a: w
> 40 a::
20
. . . . ..._. ~
... -.... --" • • • .-----------770-2 -·-·'"-·-·.... -~ ..... --- -...... -- --- -,._ --- - - -... 74 0 2 -----·-:"-"'•-'~"'-·-·-· 760-3 -----------·-----· -
~ ----..... -------: •• • \
\
\
\
\
\
\
\
\
\
• • • ~ .. 1-l.--.. ·1-----· 7 70-1
\
\
\
\
\
\
\
\
·------.. ...-------760-1 ..............
0+----------~--------~--------~--------.--------.-------,----------.-------.
SEPT OCT NOV DEC
1981
JAN FEB MAR
1982
APR
Figure 3-3-2. Movement of five radio tagged burbot in the Sus itna River, October 1981 to April 1982.
MAY
tracking was used to locate the fish, and then trotlines and burbot
~ \ '
lines were set in the vicinities of the radio tagged fish via snowmo-
b"iles. Neither of the radio tagged fish were recaptured during these
trips. Ice augering in the vicinity of burbot 770-1 in the mainstem
Susitna River at RM 68.5 did not show if the fish was alive or dead, as
no movement was detected. Two other nontagged burbot, however, were
captured utilizing 11.5 gear units of trotline and burbot set effort.
Burbot 740-2 was in the mainstem at RM 82.0 and was apparently alive
during the two recapture attempts made in March. Telemetry gear detect-
ed the fish reacting to the ice auger when drilling in the vicinity.
Movement ranged from 500 to 1 ,000 feet during three days of an early
March sampling trip. This fish was not recaptured; however, eight other
non-tagged burbot were captured in the vicinity in 16.3 gear units of
trotline and burbot set effort.
Spawning
Although no burbot were observed spawning in the Susitna River between
Cook Inlet and Devil .can,Yon during 1981 and 1982, burbot sampling
mortalities were examined for sexua 1 development monthly to document
timing of spawning.
During September and October of 1981, 31 burbot mortalities with a total
length rang·ing from 105 mm to 900 mm were necropsied. Twenty-two of
these fish had larger gonads than burbot examined in June, 1981
(Appendix Table 3-A-28). Adult burbot mortalities examined during the
1982 field season also indicated enlarging of gonads monthly. Individu-
64
al eggs were evident in eggs sacs of mature female burbot necropsied in
September and Oc· Jber. The minimum 1 ength of mature fema 1 e burbot
sampled during September and October~ 1981 was 330 mm while mature males
were at least 310 mm in length. Age -length analysis indicates both of
these fish were III or IV year olds (ADF&G 1981c).
Fourteen burbot sampling mortalities were ex.pmined for sexual develop-
ment during February and March, 1982. All of the 11 female burbot
necropsied had spawned. Residual eggs were found in the eggs sacs of
each of these female burbot. The minimum length of the females sampled
was 425 mm and the minimum age was IV (Appendix Table 3-A-28). Two of
the three males captured had also spawned.
3.1.1.4 Round Whitefish
Distribution and Relative Abundance
A total of 2,141 juvenile and adult round whitefish (Prosopium cylin-
draceum Pallas) were captured during 1982 summer field operations on the
Susitna River downstream of Devil Canyon (Table 3-3-4). Winter sampling
from February through April failed to capture any round whitefish. Most
of the round whitefish caught during the summer were captured by boat
electrofishing (51.8%) or by a downstream migrant trap (19.3%).
Nine hundred and twenty-two (43.1%) of the round whitefish captured
during the summer were caught at DFH sites (Table 3-3-4, Appendix Tables
3-A-29 and 3-A-30). Most of these fish were captured by electrofishing,
65
CT\
CT\
Table 3-3-4
Studx Site T,i:Ee
DFH Sites
SFH Sites
Round whitefish catch on the Susitna River between Cook Inlet and Devil Canyon by study site
typ~, May to October, 1982 .
MAY . JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 .1-15 16-31 1-15 16-30 1-15 TOTAL
19 43 261 163 111 55 79 78 113 922
13 67 166 11 55 52 84. 115 22 585
Downstream migrant trap 22 227 61 55 12 9 14 13 413
Fishwheel sites 1 15 15 17 10 7 14 111 32 221
TOTAL 32 125 464 418 237 169 189 313 181 13 2141
-no sample
either boat-mounted or backpack, and beach seining; only one fish was
captured by mi nnm• trapping. The highest catch of round whitefish at
DFH sites was recorded at Portage Creek where 201 fish were caught.
Other DFH sites where relatively large catches were made in 1982 were
Slough 6A, Slough 9, 4th of July Creek, and Indian River.
Round whitefish were also captured at 14 other tributaries and sloughs
above the Chulitna River confluence and at 12 other tributaries and
sloughs below the confluence (Appendix Tables. 3-A-31 and 3-A-32). A
tota 1 of 239 round whitefish were captured at these SFH sites. El ec-
trofishing and beach seining also captured 327 an& 19 round whitefish,
respectively, at mainstem sites between Cook Inlet and Devil Canyon.
The highest catch of round whitefish at SFH sites was recorded at Jack
Long Creek (RM 144.5) where 60 fish were caught. Other SFH sites where
relatively large catches were made in 1982 were the mouths of the
Talkeetna River (RM 97.0) and Skull Creek (RM 124.7), and a mainstem
site at RM 150.1. The farthest downstream site where adult round
whitefish were caught was RM 19.0, and RM 150.1 was the farthest up-
stream site for the.reach of river below Devil Canyon.
In addition to the round whitefish captured by mobile gear at DFH and
SFH sites, fish were captured by fishwheels and a downstream migrant
trap (Table 3-3-4). Two hundred and twenty-one adult fish were captured
by fishwheels. One hundred and fifty-two of these were captured at
Sunshine (RM 79.0), while 25 were recorded at Talkeetna (RM 103.0), 38
at Curry (RM 120.0), and six at the Yentna Riv~r (RM 27.5, TRM 6.0)
station (Appendix Table 3-A-33). The downstream migrant trap captured
67
410 juvenile (fork length under 200 mm) and three adult round whitefish
during 1982. The maximum seasonal catch at the trap was recorded during
early July when 227 round whitefish were captured.
The maximum catch of round whitefish by all methods was recorded in late . .
June when 464 fish were captured, 81 percent pf these fish were captured
by electrofishing. Large catches of round whitefish were also made in
• early July and earlySeptember.
Nine hundred and' ninety-nine (46.7%) of the 2,141 round whitefish
captured downstream of Devil Canyon were j uveni 1 es. Eight hundred and
forty-three of these juveniles were captured upstream of the Chulitna
River. The downstream migrant trap captured the highest percentage
(41.0%) of juveniles in comparison to other sampling methods. The
farthest downstream site where juvenile round whitefish were caught was
RM 14.8 while RM 150.1 was the farthest upstream site in the reach of
river below Devil Cany0n.
Movement and Migration
Eleven hundred and forty-five round whitefish were Fl oy anchor tagged
between 1980 and 1982, (1,008 in 1982) during a tag and recapture
program. Thirty-six round whitefish have been recaptured with 35 (97%)
of those occurring during 1982 (ADF&G 1981; Appendix Table 3-A-34). Two
of the 35 fish recaptured in 1982 were tagged in 1981. The recovery
rate of fish tagged in 1981 was 1.5 percent (2 of 137) while 3.3 percent
(33 of 1,008) of the fish tagged in 1982 have been recovered.
68
The round whitefish recaptured ·in 1982 ranged from four hours to 355
days between tim,.. of tagging and recapture. The maximum upstream
movement was 36.6 miles while the maximum downstream movement was 32.6 , I
miles. No movement was recorded for 17 (48.6%) of the 35 recaptured
fish. The maximum movement recorded for 1981 or .1982 recaptured fish
was the fish tagged and recovered in 1982 which moved 36.6 miles.
Spawning
Sexually mature round whitefish were captured at two locations in the
mainstem Susitna River between Cook Inlet and Devil Canyon during the
1981 and 1982 field seasons. Sexually ripe round whitefish were cap-
tured by electrofishing during early October, 1982 in the mainstem
Susitna River at RM 102.6 and on October 2, 1981 at RM 100.8. At both
sites, milt and eggs were discharged by palpating several captured fish.
All adult whitefish captured in 1982 over 200 mm fork length evidenced
spawning coloration (bronze on back and sides) in late May. All of the
24 adult female round whitefish necropsied between Cook Inlet and
Ta·r keetna from June to September, 1982 contained eggs. One round
whitefish captured at the mouth of Portage Creek on September 21, had
nuptial tubercles on its lateral scales.
3.1.1.5 Humpback Whitefish
Gill raker counts were taken on 26 humpback whitefish mortalities to
determine which species of the humpback whitefish complex (Coregonus
69
clupeaformis, .f.:_ nelsoni, and/or ~ pidschian) inhabits the Susitna
River. The modal gill raker count is the best method used to differ-
entiate between species. Morrow (1980) reported that in Alaska the
modal gill raker count for~ clupeaformis is 26 or more,~ nelsoni is
usually 25 and ~ pidschian is 22 or 23. Counts from Susitna River
humpback whitefish ranged from 19 to 26, with a mode of 22 (Appendix
Table 3-A-35). On this basis, the humpback whitefish present in the
Susitna River has been determined to be .f.:_ pidschian.
Distribution and Relative Abundance
A total of 553 humpback .whitefish were captured downstream of Devil
Canyon during 1982 (Table 3-3-5). No catches of humpback whitefish were
made during the winter field season. Most humpback whitefish were
captured by fi shwheels.
Humpback whitefish wer~ captured at 13 (76%) of the 17 DFH sites al-
though they were caught infrequently (Appendix Tables 3-A-36 and 3-A-
37). The greatest catches of humpback whitefish were recorded at the
Portage. Creek and Sunshine Creek and Side Channel OFH sites. A total of
23 humpback whitefish were captured at these sites while 54 were captur-
ed at all OFH sites combined.
Humpback whitefish were a 1 so captured at SFH sites (Appendix Tables
3-A-38 and 3-A-39). Boat electrofishing gear was used to capture
humpback whitefish at .eight SFH tributary or slough sites above the
Chulitna River confluence and at eight tributaries below the confluence.
70
--.J .....
Table 3-3-5
Stud~ Site T~~e
DFH Sites
SFH Sites
Humpback whitefish catch on the Susitna River between Cook Inlet and Devil Canyon by study
site type, May to October, 1982.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL
9 3 12 8 5 5 4 5 3 54
7 . 11 3 11 11 22 11 1 77
Downstream migrant trap 0 1 2 15 26 1 4 0 49
Fishwheel sites 5 9 49 25 81 148 67 8 392
TOTAL 9 15 32 61 43 112 200 84 16 572
-no sample
Thirty-five humpback whitefish were also captured at mainstem SFH sites
between Cook Inlet and Devil Canyon by boat electrofishing.
In addition, humpback whitefish were captured by fishwheels and by a
downstream migrant trap (Tab 1 e 3-3-5). A tot a 1 of 163 adult humpback
whitefish were captured in the mainstem Susitna River with fishwheels,
while another 211 were captured at the Yentna River (RM 28.5, TRM 6.0)
station (Appendix Table 3-A-40). The downstream migrant trap at RM
103.0 also captured 48 juvenile humpback whitefish. Most of the main-
stem catch was made in August.
Movement and Migration
Adult humpback whitefish were again tagged in 1982 in an attempt to
delineate seasonal movements in the Susitna River system. Over the
course of the summer field season, 268 humpback whitefish were tagged.
A tota 1 of eight recaptures of humpback whitefish were made (Appendix
Table 3-A-41). Four of these recaptured fish were initially tagged in
1981 out of a tot a 1 of 189 tagged that year. The ca 1 cul a ted recovery
rate of fish tagged in 1981 was 2.1 percent while the recovery rate of
fish tagged in 1982 was 1.5 percent.
Spawn1ng
Thirty-five humpback whitefish sampling mortalities were necropsied
during June to September, 1982. Eggs were present in all necropsied
adult females that were captured between Cook Inlet and Devil Canyon.
72
Nuptial tubercles were evident on the lateral scales of all adult
humpback whitefish captured on the Susitna River during September.
3.1.1.6. Longnose Suckers
Distribution and Relative Abundance
One longnose sucker (Catostomus catostomus Forster)-was captured during
the ice-covered months. This individual was caught in a minnow trap in
February in a mainstem side channel at RM 121.6.
During the ice-free months of May through October, 1,130 longnose
suckers were captured (Table 3-3-6). Sixty-one percent of the catch was
at the downstream migrant trap, fishwheels, or SFH sites. Boat electro-
fishing gear was used to capture 324 {73%) of the 441 longnose suckers
found at DFH sites. Longnose suckers were' captu'red at all the DFH
sites, but catches between sites varied tremendously (Appendix Tables
3-A-42 and 3-A-43). The DFH site at which the most longnose suckers
were caught was Rabideux Creek and Slough where 68 were captured. Other
sites at which more than 30 longnose suckers were captured included
Goose Creek 2, and Side Channel, Sunshine Creek and Side Channel,
Whiskers Creek and Slough, and Slough 8A. Only one longnose sucker was
captured at both Slough 11 and Slough 19. The catch was divided fairly
evenly among sampling periods over the course of the open water season.
Longnose suckers were captured at 29 SFH tributary or slough sites with
electrofishing gear (Appendix Tables 3-A-44 and 3-A-45). Fifteen of
73
......,
~
Table 3-3-6
Study Site Type
DFH Sites
SFH Sites
Longnose sucker catch on the susitna River between Cook Inlet and Devil Canyon by study site
type, May to October, 1982.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL
27 25 58 81 15 40 66 76 53 441
7 80 50 75 86 25 112 125 10 570
Downstream migrant trap 14 6 5 0 1 2 0 0 28
Fishwheel sites 11 20 21 7 16 12 4 0 91
TOTAL 34 116 142 183 113 81 191 207 63 0 1130
-no sample
these sites were below the Chulitna River confJuence and the other sites
were above the con·-1 uence. The mouth of Trapper Creek ( RM 91. 5) record-
ed the highest catch (62) of longnose suckers at the SFH sites. The
mouth of the Deshka River (RM 40.6) and a beaver pond (RM 86.3) were
also found to harbor large numbers of longnose suckers. Boat electro-
fishing gear was also used to capture 324 longnose suckers at a number
of SFH mainstem sites both above and below the Chulitna River conflU-
ence. Mainstem catches decreased after June and then gradua,ly increas-
ed in August and September. Most of the longnose suckers captured with
boat electrofishing gear had fork lengths greater than 200 mm. Ninety-
one longnose suckers were also captured in the mainstem in fishwheels
and the catch was evenly divided among the sites (Appendix Table
3-A-46).
Movement and Migration
Eight hundred and eighty-nine 1 ongnose suckers were tagged with Fl oy
anchor tags during 1982. Eighteen tag recoveries were made, three of
the recoveries were fish tagged in 1981 {Appendix Table 3-A-47). The
recovery rate of tags deployed in 1981 was 0.8 percent ( 3 of 350) while
the 1982 recovery rate was 1. 7 percent. All three of the longnose
suckers tagged in 1981 were recaptured at a location less than one mile
from where they were tagged while 11 of the 15 longnose suckers tagged
and recovered in 1982 moved one mile or less. The other four longnose
suckers recovered a 11 moved downstream and movements ranged from 1. 2 to
7. 5 miles.
75
Spawning
Sexually ripe and spent longnose suckers were captured during late May
and early June, 1982 at the mouth of Trapper Creek (RM 91.5) and below
the mouth of Sunshine Cree~.
Electrofishing gear was used to capture 28 longnose suckers ranging from
155-380 mm fork length, at the mouth of Trapper Creek on June 5 at the
interface of the mainstem and the tributary. At this time, four sexual-
ly mature and two spent longnose suckers were captured (Appendix Table
3-A-48). On June 10, only 13 longnose suckers were captured by elec-
trofishing this site.
The mouth of Sunshine Creek was the other location where evidence of
1 ongnose sucker spawning was observed. Peak spawning a 1 so occurred
before June 10 at this location; 20 longnose suckers were captured on
May 25 while only two were captured on June 10. One ripe male and one
spent female were captured on May 25.
Sexually mature males captured during May and June in the Susitna River
ranged from 293 mm to 370 mm while mature females ranged from 296 mm to
370 mm. Scale and age-length analysis of these fish indicated they were
Age V to VII (Appendix Report 3-G-1).
Ten sexually mature males were also captured by electrofishing in the
mainstem between RM 35.4 and RM 138.6 during September. All discharged
milt when palpated. In addition, five necropsied female longnose
76
suckers captured during September had very well developed eggs. Concen-
trations of longn•,se suckers were observed during September in the
mainstem between RM 35.4 and RM 47.1 in habitat similar to that found
during spring spawning.
Nuptial tubercles were evident on the anal fin of all sexually mature
males captured during May, June and September.
Young of the year 1 ongnose suckers, mean fork 1 ength of 15 mm, were
first captured during early August, 1982 at Slough 8A. Young of the
year 1 ongnose suckers were a 1 so captured at Goose Creek 2 and Side
Channel, Whitefish Slough, and Whiskers Creek and Slough.
3.1.1.7 Dolly Varden
Distribution and Relative Abundance
One Dolly Varden (Salvelinus malma Walbaum) was captured during winter
sampling efforts. This juvenile was captured in a minnow trap in March
at the mouth of Montana Creek (RM 77 .0). The majority of the 116 Dolly
Varden sampled during the ice-free months of 1982 were captured in June
and July (Table 3-3-7). During the summer field season, the majority of
Dolly Varden were captured by boat electrofishing, fishwheels, and
minnow traps.
Dolly Varden were captured at only nine (53%) of the 17 DFH sites
{Appendix Tables 3-A-49 and 3-A-50). The catch of Dolly Varden at Lane
77
" co
Table 3-3-7
Stud~ Site T,tQe
DFH Sites
SFH Sites
Dolly Varden catch on the Susitna River between Cook Inlet and Devil Canyon by study site
type, May to October, 198Z.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL
7 2 3 1 7 1 3 2 26
3 22 7 12 4 4 1. 3 56
Downstream migrant trap 0 0 7 0 0 0 0 0 7
Fishwheel sites 2 7 3 1 0 3 10 1 27
TOTAL 3 31 16 18 13 11 5 16 3 116
-no sample
Creek and Slough 8 was higher than at any other DFH site with a total of
eight captured. TJtal catch of Dolly Varden at all the DFH sites was
only 28.
Boat electrofishing gear was used capture Dolly. Varden at the mouths of
six tributary SFH sites (Appendix Tables 3-A-51 and 3-A-52). Dolly
Varden were found below the Chulitna River confluence at Kashwitna River
(RM 61.0), Gray•s Creek (RM 59.5), Talkeetna River (RM 97.0) and Goose
Creek (RM 72.0). Above the Chulitna River confluence, the mouths of
Skull Creek (RM 124.7) and Sherman Creek (RM 130.8) produced Dolly
Varden. Twelve Dolly Varden were also captured by boat electrofishing
in the mainstem below the Chulitna River confluence and three in the
mainstem above the confluence. Fishwheels captured 27 other adult Dolly
Varden in the mainstem of which 13 were captured. above the confluence
(Appendix Table 3-A-53).
Seven juvenile (fork length under 200 mm) Dolly Varden were captured in
late July by the downstream migrant trap located at Talkeetna camp (RM
103.0). Five of these fish were captured on July 26 and all were
approximately 30-35 mm in length. Juvenile Dolly Varden were also
captured at the mouths of Sunshine Creek and Side Channel, Gash Creek
(RM 111.5), Slough 6A, Lane Creek and Slough 8, 4th of July Creek, and
I
Portage Creek. Minnow trapping in upper Portage Creek and Indian River
has also shown the presence of a number of juvenile or stunted adult
Dolly Varden from 2.7 to 15.5 miles above the mouths of these streams
(Appendix Report 3-D-1).
79
Movement and Migration
Forty-six Dolly Varden were tagged in 1982 in an effort to delineate
season a 1 movements. Seven of the tags dep 1 oyed in 1981 and 1982 were
recovered (Appendix Table 3-A-54). Only one of the 59 Dolly Varden
tagged in 1981 was recovered in 1982; the recovery rate of tagged 1981
fish was 1.7 percent. The recovery rate of Dolly Varden tagged in 1982
was 13.0 percent. One of the Dolly Varden tagged in 1982 moved 25 miles
upstream between the time of tagging and subsequent recovery, the other
recaptured fish moved much smaller distances.
Spawning
No Dolly Varden were observed spawning, and no sexually mature adults
were captured during the 1982 field season in the mainstem Susitna
River.
3.1.1.8 Threespine Stickleback
Distribution and Relative Abundance
Only one threespine stickleback (Gasterosteus aculeatus L.) was captured
during the 198l-1982 winter field season. This individual was captured
at Whiskers Creek and Slough in a minnow trap in April.
An additional 267 threespine stickleback were captured during the
ice-free field season (Table 3-3-8). Minnow traps, beach seines, dip
nets, and electroshockers were used to capture the fish at DFH and SFH
80
00 ....
Tab1e 3-3-8
Study Site Type
DFH Sites
SFH Sites
Threespine stickleback catch on the Susitna River between Cook Inlet and Devil Canyon by
study site type, May to October, 1982.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15
11 24 18 5 72 47 25 17
0 1 -0 0 14 1 0 0 0 0
Downstream migrant trap 0 0 1 0 4 17 9 1
Fishwheel sites 0 0 0 0 0 0 0 0
TOTAL 12 24 18 20 73 51 42 26 1
-no sample
TOTAL
219
16
32
0
267
sites. Most of the threespine stickleback were captured below the
confluence of the Chulitna River; only 50 (18.7%) fish were captured
above the confluence. The farthest upstream location at which three-
spine stickleback were captured was at the Talkeetna station (RM 103.0)
where they were captured by the downstream migrant trap.
Threespine stickleback were captured at six of the 17 DFH sites (Appe-
ndix Tables 3-A-55 and 3-A-56). All of the five DFH sites below the
confluence were found to have threespine stickleback present. The site
at Whiskers Creek and Slough was the only DFH site above the confluence
at which threespine stickleback were captured. Catches at DFH sites
peaked in August as the juveniles reached a size where they were catch-
able.
Boat electrofishing gear captured 16 threespine stickleback at two
mainstem sites and five tributary sites below RM 80.0 (Appendix Tables
3-A-57 and 3-A-58).
Juvenile stickleback were observed at five SFH sites below the Chulitna
River confluence. Schools of juvenile stickleback were observed in late
July and early August at Lower Fish Creek (RM 7 .6), Anderson Creek (RM
23.8), Kroto Slough (RM 38.3), Rolly Creek (RM 39.0), and an unnamed
slough on the west bank (RM 57.4). At Whitefish Slough, juvenile
threespine stickleback were captured during early August. These
juveniles were 15 mm to 25 mm in length. By early September, the
juveniles had moved out of Whitefish Slough as it was nearly dewatered.
At the downstream migrant trap at Talkeetna Station (RM 103.0), 31
82
juvenile threespi ne sticklebacks were captured. Most of the juveni 1 e
catch, composed of ~3-35mm fish, was made from August 25 through Septem-
ber 26.
Movement and Migration
Since no threespine stickleback have been marked, no information is
available on threespine stickleback movement.
Spawning
Threespine stickleback ranging in length from 50mm to 100mm were ob-
served in spawning colors during early June to late July, 1982 at DFH
sites below the Chulitna River confluence. However, no adult threespine
stickleback were actually observed spawning. Young of the year three-
spine stickleback with total lengths between 15mm and 20mm were first
observed during late July and early August. Since threespine stickle-
back are only about 4.5mm in length upon hatching (Morrow 1980), these
fish were at least several weeks old at the time they were observed.
3.1.1.9 Slimy Sculpin
Distribution and Relative Abundance
All cottids that were examined in 1982 proved to be slimy sculpins
(Cottus cognatus Richardson). It is possible that several other species
of sculpin may be present in the lower Susitna River (ADF&G 1981c), but
83
it appears that the great majority of individuals at the sites sampled
in 1982 were slimy sculpins. For purposes of further discussion, all
cottids captured have been assumed to be slimy sculpins.
Slimy sculpins were captured in minnow traps at 11 sites during the ice
covered months (Appendix Table 3-A-59). A total of 43 individuals were
captured, and 13 of these were captured at Slough 22. All the slimy
sculpin were captured at slough or tributary sites. None were captured
at mainstem sites; howeveP, mjnnow trapping efforts in the mainstem were
limited (Appendix Table 3-A-5). Slimy sculpins were captured both above
and below the Chulitna River confluence.
During the ice free months of May through October, 659 slimy sculpins
were captured (Table 3-3-9). Most (82%) were captured at DFH sites and
the remainder were captured at the downstream migrant trap or SFH sites.
Minnow traps, beach seines, electrofishing units, and dip nets were used
to capture slimy sculpin.
Slimy sculpins were captured at all 17 DFH sites (Appendix Tables 3-A-60
and 3-A-61). Sampling efforts at Whiskers Creek and Slough produced the
highest number of slimy sculpin with 101 captured. More than 50 slimy
sculpin were also captured at Sunshine Creek and Side Channel, Birch
Creek and Slough, and Lane Creek and Slough 8. Only two slimy sculpin
were· captured at Slough 11 and 1 ess than 10 fish were captured at
Whitefish Slough, Slough 19, and Portage Creek. In genera 1, fewer s 1 imy
sculpin were captured at DFH sites above the confluence. The seasonal
catch at DFH sites peaked in September.
84
00
U'l
Table 3-3-9
Stud~ Site T~Ee
DFH Sites
SFH Sites
Slimy sculpin catch on the Susitna River between Cook Inlet and Devil Canyon by study site
type, May to October, 1982.
MAY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL
2 12 50 63 46 84 46 123 116 542
4 3 34 12 9 0 9 3 1 0 75
Downstream migrant trap 15 3 14 2 3 2 2 1 42
Fishwheel sites 0 0 0 0 0 0 0 0 0
TOTAL 6 15 99 78 69 86 58 128 119 1 659
-no sample
SFH tributary or slough sites at which slimy sculpin were captured
included four sites below the Chulitna River confluence and eleven above
(Appendix Tables 3-A-62 and 3-A-63). Twelve slimy sculpin were captured
at mainstem SFH sites below the confluence and 26 were captured at
mainstem SFH sites above the confluence. Slimy sculpins were often
observed at most sites electrofished by boat but few were captured due
to a selection for other resident or juvenile anadromous species and
time constraints. Slimy sculpin were observed at nearly every tributary
and slough site sampled anq they were also present at a large number of
mainstem sites.
Movement and Migration
The highest catches of adult slimy sculpin at the downstream migrant
trap (RM 103.0) were in late June and late July, although adults were
captured whenever the trap was in operation. Adult catches were fairly
constant during the ice free months at DFH and SFH sites. Winter
catches of slimy sculpin were similar to summer catches, suggesting
slimy sculpins are resident year round in specific areas.
Spawning
No data concerning slimy sculpin spawning were gathered in 1982. The
first captures of young of the year slimy sculpin was made during late
July. At this time the young were 10-15 mm in length.
86
3.1.1.10 Arctic Lamprey
Distribution and Relative Abundance
No Arctic 1 amprey ( Lampetra japoni ca Martens) were captured during the
winter field season. A total of 62 Arctic lamprey were captured in the
downstream migrant trap and at DFH and SFH sites during the open water
field season (Table 3-3-10). Arctic lamprey were captured at only three
DFH sites; the upstream most site being Whiske1~s Creek and Slough
(Appendix Tables 3-A-64 and 3-A-65). The most productive DFH site was
Birch Creek and Slough where 31 Arctic 1 amprey were caught. Seven
Arctic lamprey were captured at SFH sites downstream of RM 58.0 (Appen-
dix Tables 3-A-66 and 3-A-67). The downstream migrant trap (RM 103.0)
captured 18 Arctic 1 amprey during surruner operations (Table 3-3-10).
Catch per hour at the downstream migrant trap was consistently 1 ow,
ranging from 0.03-0.18 Arctic lamprey/hour.
In addition, two Arctic lamprey were captured while parasitizing other
fish. One was attached to a 81mm chinook salmci'n s'lnolt captured in the
mainstem at RM 31.8. The other was attached to a longnose sucker
captured at Sunshine Creek and Side Channel.
Movement and Migration
The catches of Arctic lamprey in 1982 were too low to document any
movement patterns. Populations of Arctic 1 arnprey can be anadromous or
resident (Morrow 1980).
87
00
00
Table 3-3-10 Arctic lamprey catch on the Susitna River between Cook Inlet and Devil Canyon by study site
type, May to October, 1982.
t~AY JUNE JUNE JULY JULY AUG AUG SEPT SEPT OCT
Study Site Type 16-31 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 1-15 TOTAL
DFH Sites 7 7 1 21 36
SFH Sites 0 . 0 0 0 6 2 0 . 0 0 0 8
Downstream migrant trap 2 5 3 3 0 1 3 1 18
Fishwheel sites 0 0 0 0 0 0 0 0 0 0
TOTAL 7 9 5 9 5 1 23 3 1 62
-no sample
Spawning
Arctic lamprey were observed spawning ·in Birch Creek Slough near the
mouth of Birch Creek during late June and early July. During this time,
two pairs of Arctic lampreys were observed constructing nests and
spawning as described by Morrow (1980). Although Arctic lamprey were
observed spawning only at Birch Creek Slough, ammocoetes of Arctic
lamprey were captured between RM 39.0 and RM 111.5.
3.1.2 Juvenile Anadromous Fish Species
Juvenile salmon catch data in this section are presented as sampling
site totals. For a separation by habitat zone at each sampling site,
refer to Volume 4, Appendix 4-G.
3.1.2.1 Chinook Salmon
A total of 963 juvenile chinook salmon (Oncorhynchus tshawytscha Wal-
baum) were captured by all gear types at Designated Fish Habitat (DFH)
sites from Goose Creek 2 upstream to Slough 21 during sampling conducted
from June through September, 1982 (Appendix Table 3-A-68).
The seasonal variation in distribution and relative abundance of juve-
nile chinook salmon at DFH sites on the Susitna River is summarized in
Figure 3-3-3. Lower reach samp 1 i ng sites between Goose Creek and the
Chulitna River show higher relative abundance during June and July. The
upper reach, between Chulitna River and Portage Creek, had the highest
89
1. Portage Creek
2. Slough 21
3. Slough 20
4. Slough 19
5. Indian River
6. Slough 11
7. Fourth of July Creek
8. Slough 9
9. Slough BA
10. Lane Creek
11. Slough 6A
12. Whiskers Creek
13. ~i rch Creek
14. Sunshine Creek
15. Rabideux Slough
16. Whitefish Slough
17. Goose Creek
OEVI L CANYON
JULY
1 II
00
00
00
00
00
00
00
00
00
00
00
AUG.
I II
0-
----o-.
00 o-.
00 o-.
00 o-.
00
00
SEPT.
I rr
00
~0
00
00
00
00
00 00
00
00
00
Relative Abundance Key
0 Absent 0
0 Trace 1 to 10 w Present 11 to 7l e Abundant 72 + over
-r~o sample
------------13-0 ~ 0 ~ 0 0 0 0
......-/""""'-------14-~ ~ 0 ~ ~ 0 0 0
~ • 0 0 0 0
0000000
---------17-~ 0 • • • C) 0 0
Figure 3-3-3. The seasonal variation in distribution and relative
abundance of chinook salmon juveniles at DFH sites on the
Susitna River, June through September, 1982.
90
relative abundance during August and September. Age 1+ chinook salmon
juveniles appear t'J be outmigrating in the lower; re,ach during June and
July while Age 0+ fish were observed more frequently at upper reach
locations in August and September.
A total of 515 (53.4%) of the juvenile chinooks 'salmon were captured in
the lower reach between Goose Creek 2 and the Chulitna River confluence
by all methods including boat electrofishing (Table 3-3-11). At the
upper reach sites between Chulitna River and Portage Creek, a total of
448 (46.6%) juvenile chinook salmon were captured (Table 3-3-12). The
total catch of juvenile chinook salmon captured by all gear types at DFH
sites by two week intervals is summarized in Figure 3-3-4. Most juve-
nile chinook salmon {159) in the lower reach were captured during early
July, while in the upper reach, most chinook salmon juveniles (122) were
captured during late August.
Juvenile chinook salmon were collected at 16 (94.1%) of 17 DFH sites.
Portage Creek was the only sampling location where juvenile chinooks
were not captured. Goose Creek had the highest percentage {20.6%) of
the total catch by all gear types for the lower reach (Table 3-3-11).
Whiskers Creek and Sloug~ had the highest percent (11.8%) of the total
catch for the upper reach (Table 3-3-12).
The range of catch per unit effort for minnow traps varied from a trace
(0.1) at Slough 20 and Slough 11 throughout the season to a high catch
rate of 6.2 fish per trap recorded at Goose Creek 2 and Side Channel in
early July (Appendix Table 3-A-69). The highest mean catch per minnow
91
1.0
N
Table 3-3-11. Total catch of chinook salmon juveniles by all gear types at DFH sites on the Susitna River
between Goose Creek and Chulitna River, June through September, 1982.
Percent of Total Catch
River June June July July Aug. Aug. Sept. Sept. Site Goose Ck.to Goose Ck.to
Site Mile 1-15 16-30 1-15 16-31 .1-15 16-31 1-15 16-30 Total Chulitna Portage Ck .
•.
Goose Creek 2 73.1 1 9 140 26 16 0 6 1 199 38.6 20.6
Whitefish Slough 78.7 10 3 1 0 2 0 0 16 3.1 1.7
Rabideux Slough 83.1 50 57 3 1 0 1 116 22.5 12.0
Sunshine Creek 85.7 11 51 4 40 11 0 3 0 120 23.3 12.4
Birch Creek 88.4 3 22 0 35 1 1 2 0 64 12.4 6.6
TOTALS 15 142 147 159 31 4 11 2 515 100.0 53.3
-Not sampled
Table 3-3-12. Total catch of chinook salmon juveniles by all gear types at DFH sites on the Susitna River
between Chulitna River and Portage Creek, June through September, 1982.
Percent of Total Catch
River June June July July Aug. Aug. Sept. Sept. Site Chulitna to Goose Ck.to
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Total Portage Ck. Portage Ck.
Whiskers Creek 101.2 6 44 7 4 6 9 35 3 112 25.0 11.8
Slough 6A 112.3 1 9 5 8 0 1 8 3 35 7.8 3.6
Lane Creek/51. 8 113.6 0 0 2 3 8 9 9 9 40 8.9 4.1
Slough HA 125.3 0 4 1 6 0 11 8 0 30 6.7 3.1
Slough 9 129.2 4 4 1 0 2 7 2 6 26 5.8 2.7
1.0 w Fourth of July 131.1 0 11 . 5 10 7 14 8 0 55 12.3 5.7
Mouth
Slough 11 135.3 0 1. 0 0 3 8 2 0 14 3.1 1.5
Indian River-138.6 0 1 1 1 5 18 1 0 27 6.0 2.8
Mouth
Slough 19 140.0 0 0 0 0 0 2 3 6 11 2.4 1.1
Slough 20 140.1 0 0 5 4 2 14 3 0 28 6.2 2.9
Slough 21 142.0 0 0 0 1 12 29 22 6 70 15.6 7.3
Portage Creek-148.8 0 0 0 0 0 0 0 0 0 0 0 -Mouth
TOTALS 11 74 27 37 45 122 101 33 448 100.0 46.6
z
0
:::E
...J
<(
V)
:X::
0
0 z
:i:.
(,)
w
...J
z
LLI > :::> ..,
::1:
0
\.0 ......
_p. <(
0
...J
<(
b
1--
110
120
80
· . Goose Creek -2 to Chulitna River
m Chulitna River to Portage Creek
JULY
Figure 3-3-4. The total catch of chinook salmon juveniles by two week periods for
two reaches on the Susitna River, June through September, 1982.
trap for all DFH sites from Goose Creek 2 to the Chulitna River conflu-
ence occurred in t'3rly July at Goose Creek 2 and Side Channel (Table
3-3-13), while the highest mean catch per minnow trap for all DFH sites
from the Chulitna River to Portage Creek occurred in 1 ate June at
Whiskers Creek and Slough (Table 3-3-14). The high catch per unit
effort levels recorded during late June in the upper reach, early July
in the lower reach, and the high mean catch per hour levels of the
downstream migrant trap during these periods indicate an outmigration of
Age 1+ chinook salmon juveniles. The mean catch per minnow trap by
reach is presented in Table 3-3-15 and plotted in Figure 3-3-5.
No Age 2+ chinook salmon were captured (Appendix Table 3-H-1). All Age
1 + fish had outmi grated from the study reach (Goose Creek to Portage
Creek) by the end of July. At most sampling sites, the abundance of Age
1+ fish peaked prior to the peak abundance of Age 0+ fish.
A total of 151 juvenile chinook salmon were captured, pr-imar-ily inci-
dental captures during boat electrofish·ing, at,SFH sites surveyed from
mainstem Susitna (RM 17.7) upstream to the Ma·instem E. Bank (RM 145.0)
during samp 1 i ng conducted from 1 ate May through September. A tot a 1 of
74 fish (49%) were captured at SFH locations between Cook Inlet and the
Chulitna River confluence. Upper river SFH locations between the
Chulitna River and Susitna River mile 145.0 had a total catch of 77 fish
(51%) (Appendix Table 3-A-70). The small numbers captured are a result
of the inefficiency of the gear and do not reflect any patterns. The
catch per unit effort data are presented in Appendix Table 3-A-71.
95
\.0
0'1
Table 3-3-13. Chinook salmon juveniles, mean catch per minnow trap at DFH sites on the Susitna River
between Goose Creek and Chulitna River, June through September, 1982.
June June July July Aug Aug Sept Sept
Reach River t~ile 1-15 16;..30 1-15 16-31 1-15 16-31 1-15 16-30
Goose Creek 2 73.1 0.0 0.4 6.2 1.6 0.8 0.0 0.1 0.0
and Side-Channel
Whitefish Slough 78.7 2.0 0.0 0.0 0.0 0.0 0.0 0.0
Rabideux Creek 83.1 1.9 2.7 0.1 0.0 0,0 0.1
and Slough
Sunshine Creek 85.7 0.6 2.2 0.4 4.0 1.0 0.0 0.1 0.0
and Side Channel
Birch Creek and 88.4 0.1 0.9 0.0 1.7 0.0 0.0 0.0 0.0
Slough
-not sampled
1.0
"-..!
Table 3-3-14. Chinook salmon juvenile, mean catch per minnow trap at DFH sites on the Susitna River between
Chulitna River and Portage Creek, June through September, 1982.
River June June July July Aug. Aug. Sept. Sept.
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16~30
Whiskers Creek (and Slough) 101.2 0.0 1.5 0.2 0.2 0.3 0.2 1.3 0.1
Slough 6A 112.3 0.1 0.6 0.3 0.1 0.0 0.0 0.1 0.0
lane Creek and Slough 8 113.6 0.0 0.0 0.1 0.1 0.1 0.3 0.0 0.3
Slough 8A 125.3 0.0 0.0 0.0 0.1 0.0 0.3 0.0 0.0
Slough 9 129.2 0.3 0.1 0.0 0.0 0.0 0.2 0.0 0.3
Fourth of July Creek -Mouth 131.1 0.0 0.1 0.2 0.3 0.1 0.0 0.0 0.0
Slough 11 135.3 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0
Indian River -Mouth 138.6 0.0 0.0 0.0 0.1 0.3 0.3 0.1 0.0
Slough 19 140.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3
Slough 20 140.1 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0
Slough 21 142.0 . 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0
Portage Creek -Mouth 148.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
<..0 co
Table 3-3-15. Chinook salmon juveniles, mean catch per minnow trap by reach on the Susitna River, between
Goose Creek 2 and Portage Creek, June through September, 1982.
June June July July Aug Aug Sept Sept
Reach River Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30
·'
Goose Creek 2 to 73.1--98.5 0.3 1.4 4.3 2.3 0.5 . 0.1 0.1 0.1
Chulitna River
Chulitna River to 98.5-148.8 0.1 0.7 0.2 0.1 0.2 0.2 0.4 0.2
Portage Creek
Goose Creek 2 to 73.1-148.8 0.2 1.1 1.1 0.9 0.3 0.3 0.3 0.1
Portage Creek
1-15 1-15 18·31 1•15 18·30
JUNE JULY AUGUST SEPTEMBER
Figure 3-3-5. Chinook salmon juvenile, mean catch per minnow trap at DFH sites by
reach on the Susitna River between Goose Creek 2 and Portage Creek,
June through September, 1982.
A total of 227 chinook salmon juveniles were captured during winter
sampling from February through April, 1982 at the nine of twelve DFH
sites sampled above the Chulitna River confluence (see Appendix Table
3-A-72). There was no chinook salmon juvenile catch at DFH sites below
the Chulitna River during winter sampling. Another 82 fish were captur-
ed at SFH sites between Mid Kroto Slough (RM 31.3) and Portage Creek (RM
148.8) (Appendix Table 3-A-73). It is difficult to note any trends with
this small number of fish collected. Either the sampling methods are
not efficient through the ice or in open leads at that time of year or
the fish are not present in any great numbers at these sites. Most
chinook salmon juveniles were collected at Whiskers Creek {37), Slough
10 (39), and Slough 20 (158). Chinook salmon juveniles were present
during all three months at Fourth of July Creek, Slough 10, Slough 11,
and Slough 20.
3.1.2.2 Coho Salmon
Sampling efforts conducted at DFH sites in the Susitna River, both above
and below the Chulitna River confluence, resulted in collection of
juvenile coho salmon, Oncorhynchus kisutch (Walbaum), of three different
brood years (Ages 0+, 1+, and 2+). Approximately 90 percent of the 17
DFH sites sampled had coho salmon present for at least one of the eight
sampling periods. Catch data are presented in Appendix Table 3-A-74 and
catch per unit effort data are contained in Appendix Table 3-A-75.
Small numbers of juvenile coho salmon were also collected by the use of
electrofishing boats. The downstream migrant trap, located 4.5 miles
100
upstream from the Chulitna confluence, reported catches of coho salmon
juveniles througho~t the open water season.
The seasonal variation in distribution and relative abundance of coho
salmon juveniles at DFH sites is summarized in Figure 3-3-6. Catch
rates were highest in July.
The total juvenile coho salmon catch tor all gear types including boat
electrofishing are tabulated in Table 3-3-16 for the sampling sites
located below the Chulitna River confluence. The percentage contribu-
tion of each site to the total catch by all gear types in this reach is
presented in this table. Eighty percent of the coho salmon juveniles
captured were collected from the sampling sites located below the
Chulitna River confluence. Rabideux Creek and Slough, Sunshine Creek
and Side Channel, and Birch Creek and Slough were themost productive
sites in this reach.
Total juvenile coho salmon catch data for all gear types including boat
electrofishing are presented for the reach of river above the Chulitna
River confluence in Table 3-3-17. Catches in this reach were lower than
in the reach below the Chulitna River confluence and most juvenile coho
salmon were collected in June and September. , Tributary mouths and their
associated slough habitat contributed to the majority of juveniles
collected (i.e. Whiskers Creek and Slough, Lane Creek and Slough 8, and
Fourth of July Creek). Slough 6A (an upland slough) was the most
productive juvenile coho salmon site in this reach. Coho juveniles were
collected at Slough 6A during all sampling periods. Total catches of
101
J. Portage Creek.
2. Slough 21
3. Slough 20
4. Slough 19
5. Indian River
6. Slough 11
7. Fourth of July Creek
8. Slough 9
9. Slough 8A
10. Lane Creek
11. Slough 6A
12. Whiskers Creek
13 . Hi rc h Creek
14. Sunshine Creek
15. Rabideux Slough
16. Whitefish Slough
17. Goose Creek
DEVIL CANYON
JUNE JULY AUG. SEPT.
I li I li r 1I I. II
1-0 00 0-00 Z-Q 0 00 00 00 3-Q 0 00 00 00 4-Q 0 00 00 00
~-o o 00 00 00 s..:.o 0 00 00 00 7-Q 0 00 00 80 e-o 0 00 00 00
9-Q 0 00 00 00 10-Q 0 00 00 •• 11-0. o• 00 ••
IZ-0 0 00 00 ttO
Relative Abundance Key
0 Absent 0
0 Trace 1 to 10
t) Present 11 to 71 e Abundant 72 + over
-No sample
13-•• •• •o •o 14-•• •• •o 00
~=======------1!5--• • • • • 0
16--0 0 0 0 0 0 0
·-------~--17-..,. 0 0 0 0 0 0 0 0
Figure 3-3-6. The seasonal variation in distribution and relative
·abundance of coho salmon juveniles at DFH sites on the
Susitna River, June through September, 1982.
102
,._.
0 w
Table 3-3-16, Total catch coho salmon juveniles, by all gear types at DFH sites on the Susitna River between Goose Creek 2 and
Chulitna River, June through September, 1982.
Percent of
Total Catch
GOose GOose
Creek 2 Creek 2
to to
River June June July July August August September September Site Chulftna Portage
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Totals River Creek -----
Goose Creek 2
and Sidechannel 73.1 2 9 0 0 2 2 17 1.2 0.9
Whitefish Slough 78.7 0 0 8 7 2 0 18 1.2 1.0
Rabideux Creek
and Slough 83.1 121 255 75 31 31 3 516 34.9 27.8
Sunshine Creek
and Sidechannel 85.7 89 46 183 164 58 2 5 3 550 37.2 29.7
Birch Creek
and Slough 88.7 42 84 113 63 35 7 32 2 378 25.5 20.3
Totals 133 261 297 482 177 47 72 10 1479 100 79.7
-Site not sampled.
.......
0 +=-
Table 3-3•17. Total catch of coho salmon juveniles by all gear types at DFH sites on the Susitna River between Chulitna River and
Portage Creek, June thro~gh September, 1982.
Percent of
Total Catch
Chulitna Goose
River Creek
to to
River June June July July August August September September Site Portage Portage
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Totals Creek Creek
Whiskers Creek Slough 101.2 2 28 9 0 7 37 85 22.5 4.6
Slough 6A 112.3 2 23 9 17 0 35 44 131 34.7 7.0
Lane Creek and Slough 8 113.6 0 2 0 0 0 3 40 42 87 23.0 3.1
Slough 8A 125.3 0 0 0 0 0 7 0 10 17 4.5 0.9
Slough 9 129.2 0 0 0 0 0 0 0 0.3 0.0
4th of July Creek-Mouth 131.1 0 0 0 0 0 24 5 30 8.0 1.6
Slough 11 135.3 0 5 0 0 0 0 4 10 2.7 o.s
Indian River-Mouth 138.6 0 0 0 0 0 6 8 2.1 0.4
Slough 19 140.0 0 0 0 0 0 0 0 0 0 o.o 0.0
Slough 20 140,1 0 0 0 8 0 0 0 0 8 2.1 0.0
Slough 21 142,0 0 0 0 0 0 0 0 0,3 o.o
Portage Creek-Mouth 148.8 0 0 0 0 0 0 0 0 0 0.0 0.0
Totals 4 59 20 27 18 137 112 378 100.0 19.7
juvenile coho salmon by reach are presented in Figure 3-3-7 for each of
the samp 1 i ng peri 01~5.
The minnow trap data is presented as catch per unit effort values in
Tables 3-3-18 and 3-3-19 for DFH sites located in both the upper and
lower reaches of the Susitna River. As minnow trap data dominated the
collection efforts for coho salmon, these trends are similar to those
indicated for total catch with all gear types. The catch per unit
effort for all sampling sites in each of the reaches sampled is por-
trayed on Table 3-3-20. These values are plotted on Figure 3-3-8.
Coho salmon juveniles of age class other than Age 0+ were present in the
two reachs for the entire open water season (Appendix Table 3-H-2). The
peak abundance of age classes greater than Age 0+ otcurred prior to the
peak abundance of Age 0+ fish.
The juvenile coho catch and CPUE data collected at SFH sites is present-
ed in Appendix Table 3-A-76 and 3-A-77. These small numbers collected
reflect the ineffectiveness of the boat-mounted electrofishing gear for
the collection of juveniles, rather than any pattern or trepd in dis-
tribution.
Winter sampling for juvenile salmon was conducted at 32 sites from
Mid-Kroto Slough (RM 36.3) to Portage Creek (RM 148.8) from February
through April, 1982. Juvenile coho salmon catches were low at all
sites. A total of 92 coho salmon juveniles were captured (Appendix
105
1--'
0
O'l
490
z 420
0
2
cl
(/)
0 380 :s:
0
0
l&J
.J
-280 z
l&J
>
::;:) ..,
:s: 210
0 ....
<(
0
.J
<( 140 ....
~
70
0
Goose Creek-2 to
Chu I itna R lver
f77l Chulitna River to
rL.Ll Porta oe Creek
Figure 3-3-7. The total catch of coho salmon juveniles by two week periods for two
reaches on the Susitna River, June through September, 1982.
~
0
-....J
Table 3-3-18. Coho salmon juveniles, mean catch per minnow trap at DFH sites on the Susitna River between Goose Creek 2 and
Chulitna River, June through September, 1982.
River June June July -July August August Sept
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15
Goose Creek 2
and Side Channel 73.1 o. 1 0,4 o.o o.o o.o 0.0 o. 1
Whitefish Slough 78.7 0.2 o.o 0.0 0.7 0.7 0.1
Rabideux Creek
and Slough 83.1 4.0 12.1 3.4 0.4 1. 0
Sunshine Creek
and Side Chanfiel 85.7 5.5 2.2 18. 1 16.4 5.8 o.o 0.2
Birch Creek
and Slough 88.4 1 • 1 3.1 4.5 3.0 2.1 0.2 0.8
-Site not sampled.
Sept
16-30
o. 1
o.o
0.2
0.2
0.0
Table 3-3-19. Coho salmon juveniles, mean catch per minnow trap at DFH sites on the Susitna River between the Chulitna River and
Portage Creek, June through September, 1982.
River June June July July August August Sept Sept
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30
Whiskers Creek
and Slough 101.2 0.1 0.9 0,4 0.0 o.o 0.2 1. 2 o.o
Slough 6A 112.3 o. 1 1.5 0.3 0.8 o.o o. 1 1.2 4.3
Lane Creek
and Slough 8 113,6 0.0 o. 1 0.0 0.0 o.o 0.0 1.2 2.3
Slough BA 125.3 0.0 o.o o.o o.o o.o 0.0 0.0 0.0
Slough 9 129.2 o.o o.o 0.0 0.0 o.o 0.0 0.0 0.0
4th of July Creek
Mouth 131.1 o.o 0.0 0.0 0.0 o.o o.o 1.7 0.0
Slough 11 135,2 0.0 0,0 o.o 0,0 o.o o.o 0.0 o.o
Indian River -Mouth 138.6 o.o 0.0 0.0 0.0 o.o o.o o.o o.o
1--'
0 Slough 19 140.0 0.0 o.o o.o o.o o.o 0.0 0.0 0.0 co
Slough 20 140,1 0.0 0.0 0.0 0.0 o.o 0.0 0.0 0,0
Slough 21 142.0 0.0-o.o 0.0 o.o o.o o.o 0.0 o.o
Portage Creek Mouth 148.8 o.o 0.9 0.0 0.0 0.0 0.0
-Site not sampled.
Table 3-3-20. Coho salmon juveniles, mean catch per minnow trap at DFH sites by reach on the Susitna River, between Goose Creek 2 and
Portage Creek, June through September, 1982.
River June June July July August August Sept Sept
Reach Mne 1-15 16-:-30 1-15 16-31 1-15 16-31 1-15 16-30
Goose Creek 2 to 73.1-
Chulitna River 98.5 2.0 2.3 4.8 6.2 2.2 0.2 0.5 o. 1
Chulitna River to 98.5-
Portage Creek 148.8 0.0 0.2 0.1 o.o 0.0 0.0 0.5 0.4
Goose Creek 2 to 73.1-
Portage Creek 148.8 0.5 0,8 1.0 1.6 0.6 0.1 0.5 0.3
........
........
0
a..
<t a:: .._
~
0 z z
::!:
a::
LLI a..
:I:
0 .._
<t
u
z
<t w
~
7.0
6.0
3 .
2.
1.0
~~
_ .. ---··-
.... .. ....
.... , ,, "',
' ', . . .
'• ' . . ... ..
Goose Creek-2
to Chulitna River
Chulitna River
to Portage Creek
Goose Creek-2
to Portage Creek
Figure 3-3-8. Coho salmon juvenile, mean catch per minnow trap at DFH sites by reach
on the Susitna River between Goose Creek 2 and Portage Creek, June
through September, 1982.
Tables 3-A-78 and 3-A-79). The most productive sites for juvenile coho
salmon were Rustic Wilderness (21 fish), Whiskers Creek and Slough (16
fish), Slough 6A (19 fish) and Slough 9 (13 fish).
3.1.2.3 ·Chum Salmon
A total of 1,231 juvenile chum salmon (Oncorhynchus keta Walbaum) were
taken by all gear types~ p~imarily by beach seining and backpack elec-
trofishing, from June through September at the 17 DFH sites (Appendix
Table 3-A-80). The seasonal variation in distribution and relative
abundance of juvenile chum salmon is summarized in Figure 3-3-9. The
early summer outmigration of juvenile chum salmon from the system is
clearly shown. The peak juvenile catch at the downstream migrant trap
occurred in late June. No chum salmon juveniles were captured at DFH
sites in the upper reach after early July. The last chum salmon juve-
nile captured at DFH sites in the lower reach was captured at Birch
Creek and Slough in early August. However, the downstream migrant trap
located 4.5 miles above the Chulitna River confluence, continued to
catch juvenile chum salmon until mid-August.
A total of 126 chum salmon juveniles were captured in the Goose Creek to
Chulitna River reach (Table 3-3-21). Eighty-two· chum salmon fry were
captured at Birch Creek and Slough, accounting for 64.3% of the total
catch for sites in this reach. Goose Creek 2 and Side Channel accounted
for the majority (22.2%) of the remaining chum .salmon fry caught in this
reach. Rabideux Creek and Slough was the only site in this reach where
chum salmon fry were not captured.
111
l. Portage Creek
2. Slough 21
3. Slough 20
4. Slough 19
5. Indian River
6. Slough 11
7. Fourth of July Creek
8. Slough ·g
9. Slough BA
10. Lane Creek
11. Slough 6A
12. Whiskers Creek
13. Hi rch Creek
14. Sunshine Creek
15. Rabldeux Slough
16. Whitefish Slough
17. Goose Greek
JUNE JULY AUG. SEPT.
I li I II :t !I r !I
• wo 00 00
0 ~0 00 00
" 00 00 00 • 0 0 00 0 • 0 00 00
7--.. 00 00 00 e-w. ~0 00 00 9-" 0 00 00 00
10-Q. 00 00 00
II-· ._ 00 0 00
12.-· -~-00 00
Relative Abundance Key
0 Absent 0
--Trace 1 to 100 e Present 100 + over
-No sample
13-w w ~--~0 00
14-w 0 0-00 0-
1!5--0
16--
0 0 0 0
0 0 0 0 0
~-----.....,..--17-• • 0 0 0 0 0 0
Figure 3-3-9. Seasonal variation in distribution and relative
ablmdance of chum salmon juveniles at DFH sites on the
Susitna River, June through September, 1982.
112
...... ...... w
Table 3-3-21. Total catch of chum sa"il;;on juvenil-es by all gear types at DFH sites on the Susitna River between Goose Creek 2 and
Chulitna River, June through September 1982.
Percent of
'Total Catch
Goose Goose
Creek 2 Creek 2
to to
River June June July July August August September September Site Chulitna Portage
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Totals River ~reek ----
Goose Creek 2
and Side Channel 73.1 3 25 0 0 0 0 0 0 28 22.2 2.3
Whitefish Slough 78.7 3 0 0 0 0 0 0 0 3 2.4 0.2
Rabideux Creek and
Slough 83.1 0 0 0 0 0 0 0 o.o 0.0
Sunshine Creek and
Side Channel 85.1 14 0 0 0 0 0 0 0 14 11.1 1. 1
Birch Creek and
Slough 88.4 41 21 16 2 1 0 0 0 81 64.3 6.7
Total 61 46 16 2 1 0 0 0 126 100.0 10.3
-Site not sampled.
The reach from Chulitna ~iver to Portage Creek accounted for 89.4
percent (1104) of the chum salmon juveniles caught by all gear types at
DFH sites (Table 3-3-22). Slough 6A produced 895 chum fry, 81.1% of the
catch above the Chulitna River and 72.7% of the total season catch for
both reaches. Beach seine hauls accounted for 92.7% of the fish. Lane
Creek produced ~8 fry, 5. 3% of the tot a 1 in the Chu 1 itna River to
Portage Creek reach. Forty chum salmon fry were captured at Slough BA.
These three sites, in a.13 mile stretch of river, accounted for 993 fry,
representing 80.7% of the total seasonal catch of juvenile chum salmon
for all DFH sites. The total catch for each reach is shown in Figure
3-3-10.
The percentages of the total chum salmon juvenile catch by each reach is
illustrated in Figure 3-3-11. Because chum salmon were not susceptible
to minnow trapping, most of the collection efforts were completed by
methods that are difficult to provide comparable quantitative data
between sites. Beach seines and el ectrofishi ng equipment provided the
bulk of the catches. Because of this problem in collection, the numbers
and percentages presented for this species often reflect the efficiency
of the sampling gear used at a particular site rather than the percent-
age of fish at each site. Areas of limited conductivity, heavy debris
1 oads, or rough substrate all contribute to decreased gear efficiency.
Changes in collection. efforts to provide more comparable catch data
among sites are planned for the 1983 field season.
Twenty-nine additional chum salmon fry were incidentally collected at
five SFH sites from RM 86.3 to RM 133.8 (Appendix Table 3-A-81). The
114
1-' ,_.
U'1
Table 3-3-22, Total catch of chum salmon juvenil~s by all gear types at DFH sites on the Susitna River between Chulitna River
and Portage Creek, June through September, 1982.
Percent of
Total Catch
Chulitna Goose
River Creek
to to
River June June July July August August September September Site Portage Portage
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Totals Creek Creek
Whiskers Creek Slough 101.2 8 0 0 0 0 0 0 9 0.8 0,7
Slough 6A 112.3 890 5 0 0 0 0 0 0 895 81.1 72.7
Lane Creek and Slough 8 113.6 0 58 0 0 0 0 0 0 58 5.3 4,7
Slough SA 125.3 40 0 0 0 0 0 0 0 40 3.5 3.2
Slough 9 129.2 5 13 2 0 0 0 0 0 20 1.8 1,6
4th of July Creek-Mouth 131.1 0 8 0 0 0 0 0 0 8 0.7 0.6
Slough 11 135.3 0 15 0 0 0 0 0 0 15 1,4 1.2
Indian River-Mouth 138.6 0 28 0 0 0 0 0 0 28 2.5 2.3
Slough 19 140.0 0 4 0 0 0 0 0 0 4 0.4 0.3
Slough 20 140.1 0 0 3 0 0 0 0 0 3 0.3 0.2
Slough 21 142.0 0 22 2 0 0 0 0 0 24 2.2 1. 9
Portage Creek-Mouth 148.8 0 0 0 0 0 0 0 0 0
Totals 943 153 8 0 0 0 0 0 1104 100.0 89.4
-Site not sampled.
-8oo1e Creek-2 to Chulitna River
~ Chulitna River to Portage Creek
11.1
...J -z
lOt 11.1
>
;:) ..,
z
0
~
...J
< en
~
;:)
:I:
0
101
:I:
0 ..... <·
0
....J
<( .....
0 ......
Figure 3-3-10. Total catch of chum salmon juveniles by two week
periods for two reaches on the Susitna River, June
through September, 1982.
116
LLI
..J
z
llJ > :::> ..,
z
0
~
..J
ct
(I)
~
:::>
:I:
(.)
:I:
(.) ...
ct
(.) ... z w
t)
a::
llJ a..
-Goose Creek-2 to Chulitna River
m Chulitna River to Portage Creek
DATE
Figure 3-3-11. Percentages of the total chum salmon juvenile catch
caught in two reaches of the Susitna River, June
through September, 1982.
117
small numbers collected are a result of the inefficiency of the gear
(boat-mounted electrofishing) and do not reflect any patterns.
Winter sampling included 32 sites between the Mid Kroto Slough (RM 36.3)
and Portage Creek (RM 148.8) in February, March and April, 1982. Most
of the 90 chum salmon juveniles were collected from four sloughs above
the Chulitna River confluence. Twenty six chum juveniles were captured
at Slough 8A. Twenty-eight chum fry were captured in Slough 11.
Twenty-six fry were captured in Slough 21. With the exception of two
fish taken at Lane Creek and Slough 8 with a fry trap, a 11 fry were
collected with a shovel and a dip net. Only 90 chum juveniles were
collected all winter, but thousands more were observed during a sampling
trip in late April. An est·imated 5,000 juvenile chum salmon were
observed in the upper reach of Slough 8A. Several hundred fish were
observed in each of three more sloughs (Slough 11, Slough 20, and Slough
21). Smaller numbers of fish were observ~d in Slough 9. The patchiness
of the catch illustrates the difficulties of sampling this species
during the winter period. Minnow traps are not effective for this
species and it is very difficult to use beach se·ines or backpack elec-
troshockers through open leads in the ice which are often inaccessible
or too small to sample effectively.
3.1.2.4 Sockeye Salmon
A total of 1413 sockeye salmon (Oncorhynchus nerka Walbaum) juveniles
were captured .by all gear types, primarily by beach seining, from June
through September, 1982, at the 17 DFH sites (Appendix Table 3-A-82).
118
The seasonal variation in distribution and relative abundance is sum-
marized in Figur0 3-3-12. Sockeye salmon juveniles were present
throughout both reaches for the entire open water season. In general,
catches were lower in the lower reach of river {below the Chulitna River
confluence) than in the upper reach. Bi~ch Creek and Slough, the
uppermost site in the reach be 1 ow the Chulitna River confluence, ac-
counted for over 50% of the juvenile sockeye salmon caught in that reach
{Table 3-3-23).
The reach from the Chulitna River confl i.Jence to Portage Creek accounted
for 93.7% of the juvenile sockeye salmon collected from all DFH sites
(Table 3-3-24). A total of 1,144 sockeye fry, 81.0% of.the total catch
at DFH sites in both reaches for the entire ice-free season, were
captured in the lower section (RM 101.2 -RM 125.3) of this reach.
Slough 6A and Slough 8A accounted for 1081 fry, 76.5% of the season
tota 1 for both reaches. Sockeye salmon fry were present at these two
sites during each sampling trip. The total catch for each reach is
shown in Figure 3-3-13.
The percentages of the total sockeye salmon juvenile catch for each
reach is presented in Figure 3-3-14. This figure represents the actual
catch, but probably does not accurately reflect the true distribution of
sockeye salmon juveniles in the river. The methods used which are
effective in capturing sockeye fry (beach seining and electrofishing) do
not lend themselves to site to site comparisons.
1.19
1 . Portage Creek
2. Slough 21
3. Slough 20
4. Slough 19
5. Indian River
6. Slough 11
7. Fourth of July Creek
8. Slough 9 ·
9. Slough SA
10. lane Creek
11. Slough 6A
12. Whiskers Creek DEVIL CAN 'I' ON
13. IHrch Creek
14. Sunshine Creek ·
15. Rabideux Slough
16. Whitefish Slough
17. Goose Creek
JUNE JULY AUG. SEPT.
I II r II I II r II
1----2--. .-o (i0 .-o
3--0 fifi fiO 00 4--.. -fi fiO 00
!5--0 00 fiO 0
fi Oli 00 fiO
7--0 Oli 00 00
B-0 fi .,., 00 (i0 9-., ., --· .,., .. 0 10-0 ., 00 00 li .,
II-· fi •• • ••
12-0 ---00 00
Relative Abundance Key
0 Absent 0
_, Trace 1 to 100
• Present 100 + over
-No sample
13-., ., "" o-00 14-0 0 0-o-. 0-
G-O CliO -o o.-.,.,
-17 r ··. () 'ii rJ w 'ii W 0
Figure 3-3-12. Seasonal variation in distribution and relative abundance
of. sockeye salmon juveniles at DFH sites on the Susitna
River, June September, 1982.
120
.......
N .......
Table 3-3-23, Total catch of sockeye salmon juveniles by all gear types at DFH sites on the Susitna River between Goose Creek
2 and Chulitna River, June through September, 1982.
Perc.ent of
Total Catch
Goose Goose
Creek 2 Creek 2
to to
River June June July July August August September September Site Chulitna Portage
Site Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Totals River Creek
Goose Creek 2
and Sidechannel 73.1 0 0 3 0 3 6 4 0 16 18.2 1.1
Whitefish Slough 78.7 0 0 0 D 3 5 5.7 0.4
Rabideux Creek and
Slough 83.1 0 0 D 0 13 0 14 15.9 1.0
Sunshine Creek and
Sidechannel 85.1 0 0 0 0 0 3 0 0 3 3.4 0.2
Birch Creek and
Slough 88.4 2 2 35 9 0 0 2 0 so 56.8 3.5
Total 2 2 39 9 3 10 20 3 88 100.0 6.2
-Site not sampled.
......
N
N
Table 3-3-24. Total catch of sockeye salmon juveniles by all gear types at DFH sites on the Susitna River between
Chulitna River and Portage Creek, June through September, 1982.
River June June July ·July August August September September Site
Habitat Location Mile 1-15 16-30 1-15 16-31 1-15 16-31 1-15 16-30 Totals
Whiske_rs Creek and Slough 101.2 0 0 11 0 0 0 0 12
Slough 6A 112.3 223 16 173 375 2 23 6 819
Lane Creek and Slough 8 113.6 0 2 0 0 0 16 13 20 51
Slough SA 125,3 2 19 207 4 13 9 7 262
Slough 9 129.2 0 7 6 2 0 0 4 0 19
4th of July Creek-Mouth 131.1 0 0 0 0 0 0 0
Slough 11 135.3 0 8 0 9 0 0 10 7 34
Indian River-Mouth 138.6 0 0 0 2 0 0 0 3
Slough 19 140.0 0 40 0 8 23 2 10 10 93
Slough 20 140.1 0 0 3 2 0 0 0 6
Slough 21 142.0 0 2 0 20 0 2 0 25
Portage Creek-Mouth 148.8 0 0 0 0 0 0 0
Totals 224 77 213 605 52 33 71 50 1325
-Site not sampled.
Percent of
Total Catch
Chulitna Goose
River Creek
to to
Portage Portage
Creek Creek
0.9 0.8
61.8 58.0
3.6 3.6
19.8 18.5
1.4 1,3
o. 1 0.1
2.6 2.4
0.2 0.2
7,0 6.6
0.5 0.4
1. 9 1. 8
0.0 0.0
100.0 93.7
-Goo•• Creek-2 to Chulitna River
lA.i
..J fZJ . Chulitna River to Portot• Creek
z
L&J > :::. ..,
z
0
10
2 ::e
_J
ct
(/)
uJ
>-L&J
~
0
0
(/)
:I:
0
1-ct
101 0
_J
_ct
1-
0
1-
Figure 3-3-13. Total catch of sockeye salmon juveniles by two week
periods for two reaches of the Susitna River, June
through September, 1982.
123
100
90 • Goose Creek -z to Chulitna River w
_J
z
f7A River to Creek liJ Chulitna PortaQe :> ::::> 80 ...,
z
0
:::!: 70 _J
<C en
w
>-60 w
:::.:::
()
0 en 50
:::r:
u
t-
<C u 40
t-z w
() 30 a::
w
fl..
20
DATE
Figure 3-3-14. Percentages of the total sockeye salmon juvenile catch
caught in two reaches of the Susitna River, June
through September, 1982.
1?4
The majority of the Age 1+ sockeye salmon captured were taken at Slough
6A in early June {~ppendix Table 3-H-3). No Age 1+ sockeye salmon were
captured in the reach sampled (Goose Creek to Portage Creek) after the
end of July.
Eighty sockeye salmon juveniles were captured at eight SFH sites between
Kroto Slough and to Slough 22 (Appendix Table 3-A-83). The small
numbers collected are a result of the inefficiency of the gear (primar-
ily boat electrofishing) and do not reflect any patterns.
A total of 17 sockeye salmon juveniles were caught at the 32 winter
sampling sites between RM 125.3 and 142.0. Eleven fry were captured at
Slough 11, six at Slough 21, two at Slough SA, and one at Slough 9. The
sockeye juveni1e captured at S1ough 9 was the on1y Age 1+ fish co11ected
during the winter survey; it was 51 mm long. The remaining fry were all
Age 0+ (from the 1981 brood year). The low numbers captured reflect the
ineffectiveness of the primary sampling gear used (minnow traps) in
capturing this species.·.
3.1.2.5 Pink Salmon
Only one juvenile pink salmon (Oncorhynchus gorbuscha wa-lbaum) was
captured by the mobile juvenile anadromous fish studies crew. All pink
salmon data are presented in the emergence and outmigration section
(Section 3.2.5).
125
3.2 Emergence and Outmigration Studies
The following results for the timing of emergence and outmigration and
for the determination of the relative condition and stage of development
by species for juvenile salmon are presented by reach of river above and
below the Chulitna River confluence. Data collected at the downstream
migrant trap and during surveys conducted at Designated Fish Habitat
(DFH) sites and Selected Fish Habitat (SFH) sites have been combined.
The surveys were separated by month during the spring studies conducted
from February through May, and were organized as two periods per month
for the summer surveys conducted from June through early October.
Daily catch per hour for the five species of juvenile salmon collected
in the downstream migrant trap was adjusted for the periods not sampled
by computing the mean of the catch rates recorded for the day preceding
and the day following each unsampled period. The cumulative catch
totals for each species were expanded to 24 hour periods, and these were
adjusted for the periods not sampled by tabulating the mean of the catch
totals recorded for the three days preceding and the three days follow-
ing each unsampled period.
Resident fish species collected in the downstream migrant trap are
presented in Appendix Table 3-B-1 and the results are included in the
section on relative abundance and distribution of resident fishes
(Section 3. 1. 1) .
126
The scale analysis data provided for chinook, coho; and sockeye salmon
repr·esent the ranc.? of lengths only of fish for which scales were
collected and are not intended to represent the limits of the ranges of
tota 1 1 ength for the fish present dur·i ng the surveys.
3.2.1 Chinook Salmon
Juvenile chinook salmon (Oncorhynchus tshawytscha Walbaum) were observed
from the mouth of the Susitna River upstream to RM 145.0 during 1982.
' Three hundred, nine fish were collected at DFH ·and SFH sites from
February through April (Appendix Tables 3-A-72 and 3-A-73). The down-
stream migrant trap captured 309 juvenile chinook salmon during its
operation from June 18 to October 12 (Appendix Table 3-B-2). Surveys of
DFH sites recorded timing data from 364 chinook salmon juveniles col-
lected from late May through October at slough, side channel, and
tributary mouth habitats in the reach of river between the Chulitna
River confluence and Devil Canyon {Appendix Table 3-A-68). Sampling
conducted in the same reach using boat-mounted electrofishing gear over
a broader range of habitats resulted in the collection of 78 juvenile
chinook salmon (Appendix Table 3-A-70). Below the confluence of the
Chulitna River, surveys of DFH sites collected 508 fish and boat elec-
trofishing gear collected 102 chinook salmon juveniles.
Overwintering chinook salmon from the 1980 brood year were observed at
numerous sites surveyed during February through April {Appendix Tables
3-A-72 and 3-A-73). They a 1 so were collected by the combined mobile
127
sampling techniques during late May and early June (Appendix Table
3-A-68 and 3-A-70).
The catch rate for juvenile chinook salmon in the downstream migrant
trap averaged 0.55 fish per hour during the first sampling period in
late June with a peak catch rate of 1.24 fish per hour occurring on June
28 (Figure 3-3-15). Juvenile chinook salmon catch rates in the trap
averaged 0.48 fish per hour during early July and 0.27 fish per hour
during late July. The peak catch rate for July was 1.15 fish per hour
recorded on July 18.
August catch rates for juvenile chinook salmon in the downstream migrant
trap decreased below 0.10 fish per hour with a high catch rate for the
period of 0.21 fish per hour occurring August 1. By September, the
average catch rate in the trap for this species was 0.01 fish per hour
with a peak catch rate of 0.56 fish per hour observed on September 20.
The last capture of juvenile chinook salmon during 1982 was recorded
October 3 (Figure 3-3-16).
In .order to provide an indication of condition and age of downstream
migrants, length measurements and age determinations were collected for
a representative subsample of fish. During surveys conducted from
February through April, 310 juvenile chinook salmon were measured. A
total of 302 chinook s~lmon juveniles captured in the downstream migrant
trap were measured for total length, and over 1,150 fish were measured
from mobile survey collection efforts conducted both above and below the
Chulitna River confluence.
128
0:: 2
~
0
:I:
.......
:I: L en -lL
JULY SEPTEMBER 1 OCT.
Figure 3-3-15. Chinook salmon juveniles, downstream migrant trap catc~ rates averaged by
three day periods, June through October, 1982.
1--'
w
0
cc
::>
0
:X:
cc
LLI a..
J:
(.)
t-
<(
(.)
v1 --~--~ -------CHUM
COHO
SOCKEYE
CHINOOK IC\1 .,.
lr-:
lo
It-
I
I
I
I.
I~
(:
l :
:1 •
·I ·. :I .
. I .
CD
co
CD
0 ....
e I t •
I . •
: I :; ",
• • I \
. \ I
'10
:10
:o
:o
·I-
:1\\,f\\
=t·'.J' \\
, \ / '"\.. I I I ' .
I \I V
'J
6/18 6
• 0
0 •
I o o
0 0
oO .
• 0
o'
. . . . .
.
0 •
"\ I • /1\ \ '/' 1\
' /I \ '--I• '.,·. I '
'\...._../I \ ',,.... .. · •• :' \~ 1 ~',/ \.,
\ I '\ ..._ • •
,\. -.,.... ...... ~ • -------_I I ' :. ..... .....
V'o ...... o ~ j' o ~· . . . ........ .. . . . . . . . . . . . . . ...... --..... . .... . . --.._.''
8/27 9/6 9/16 9/26 10/6 10!12
Figure 3-3-16. Downstream migrant trap catch rates by three day periods for juvenile
chinook, coho, chum, and sockeye salmon, June 18 through October 12, 1982.
All fish collected during the spring surveys were from the 1980 brood
year and were undevgoing their first winter in fresh water. Beginning
in May with the first captures of juvenile chinook salmon from the 1981
brood year, two age classes, Age 0+ and Age 1+, were present. Corre-
lations of complimentary size frequency distribution and scale analysis
data were used to determine the age class composition of the fish
measured (Table 3-3-25). A length of 66 mm was determined to represent
the minimum length of chinook salmon Age 1+ co"llected between the
Chulitna River confluence and Devil Canyon for the first two weeks of
June. Attributing an increase in total length of five millimeters for
each successive two-week survey period (based on 1981 studies, ADF&G
1981b), the minimum lengths for Age 1+ chinook salmon for late June,
early July, and late July were set at 71 mm, 76 mm, and 81 mm, respec-
tively. Scale sample analysis showed that only one Age 1+ fish was
collected during early August and that no Age 1+ chinook salmon were
collected above the Chulitna River confluence after early August.
Fish collected during February had a mean length of 70 mm with a range
of 53 mm to 90 mm (Table 3-3-26). March surveys captured chinook salmon
juveniles ranging from 51 mm to 98 mm with a mean length of 80 mm, and a
mean length of 77 mm was determined for fish collected during April with
a range from 61 mm to 97 mm.
The mean 1 ength and range of 1 engths for Age 0+ and Age 1+ chi nook
salmon captured by two-week period between the Chulitna River confluence
and Devil Canyon from May to October is presented in Table 3-3-27. Age
I+ fish collected during late May and early June had a mean length of 84
131
Table 3-3-25 Chinook salmon juveniles, scale analysis of age class
composition for collected fish by survey period between
Cook Inlet and Devil Canyon, 1982.
Age 0+ Age 1+
1981 Brood Year 1982 Brood Year
Number Range of Number Range of
of Lengths of Lengths
Surve,Y Period Fish (mm) Fish (mm)
February to May 0 10 87-100
June 1-15 0 6 78-98
June 16-30 8 55-69 59 75-112
July 1-15 0 14 86-106
July 16-31 11 57-86 5 85-95
August 1-15 13 63-80 1 117
August 16-31 7 77-94 0
September 1-15 10 74-86 0
September 16-31 6 77-92 0
October 1-12 0 0
132
Table 3-3-26 ·Chinook Salmon juveniles, mean length and range of
lengths between Cook Inlet and the Chulitna River
confluence, and between the Chulitna River confluence and
Devil Canyon, February to April, 1982.
Cook Inlet to Chulitna Chulitna to Devil Can,ton
Number Mean Range of Number Mean Range of
of length lengths of Length lengths
Surve,t Period Fish (mm) (mm) Fish (mm) (mm)
February 0 130 70 53-90
March 14 78 57-90 77 80 51-98
Apri 1 2 77 69-85 87 77 61-97
133
Table 3-3-27 Chinook salmon juveniles, mean length and range of
lengths by age class between the Chulitna River
confluence and Devil Canyon, May to October, 1982.
Age 0+ Age 1+
Number Mean Range of Number Mean Range of
of Length Lengths of Length Lengths
Date Fish (mm) (mm} Fish (mm} (mm}
May 16-31 0 2 90 85-95
June 1-15 1 40 40 38 84 68-100
June 16-30 19 49 34-70 142 89 71-125
July 1-15 67 55 36-74 63 92 76-115
July 16-31 139 54 36-77 17 90 83-108
August 1-15 84 61 39-88 1 117 117
Aug. 16-31 65 64 42-94 0
Sept. 1-15 100 69 41-95 0
Sept. 16-30 41 69 47-100 0
Oct. 1-12 1 80 80 0
134
mm with a range from 68 mm to 100 mm. By late June, the mean length had
increased to 89 mn-with a range from 71 mm to 12!:1 mm. Age 1+ chinook
salmon collected during July ranged in length from 76 mm to 115 mm and
had a mean length of 90 mm. The last Age 1+ chinook salmon collected
above the Chulitna River confluence was captured during early August and
measured 117 mm.
Age 0+ chi nook salmon captured above the confluence of the Chulitna
River in early June had a mean length of 49 mm with a range from 34 mm
to 70 mm (Appendix Figure 3-B-1). By early September, the mean length
for Age 0+ fish in this reach was 69 mm with a range from 41 mm to 95
mm.
Appendix Figure 3-B-2 provides the percent length frequency distribution
by two-week period for juvenile chinook salmon collected below the
Chulitna River confluence. Utilizing the same length separation between
Age 0+ and 1+ fish which was determined for the reach above the conflu-
ence of the Chulitna River, Age 1+ chinook salmon mean lengths in the
lower reach ranged from 80 mm in late May to 89 mm in late July (Table
3-3-28}. Only two Age 1+ fish were measured during August and the last
capture of Age 1+ chinook salmon in this reach was recorded during early
September when a 130 mm fish was collected in a small backwater slough
at RM 17.7.
Age 0+ chinook salmon collected below the Chulitna River confluence had
a mean length of 61 ITUll with a range from 51 mm to 70 mm in early June
135
Table 3-3-28 Chinook salmon juveniles, mean length and range of
lengths by age class between the Chulitna River
confluence and Devil Canyon, May to October, 1982.
A~e 0+ Age 1+
Number ean Range of Number Mean Range of
of Length Lengths of Length Lengths
Date Fish (mm) (mm} Fish (mm} (mm1
May 16-31 0 9 80 68-87
June 1-15 7 61 51-70 21 84 72-118
June 16-30 63 64 51-75 80 84 75-115
July 1-15 65 69 54-80 15 86 81-91
July 16-31 176 74 42-85 7 89 86-95
Aug. 1-15 38 74 38-89 2 92 92
Aug. 16-31 11 74 55-92 0
Sept. 1-15 14 75 56-101 1 130 130
Sept. 16-30 3 74 56-84 0
Oct. 1-12 0 0
136
and had reached a mean length of 75 mm by early September with a range
from 56 mm to 101 1":m.
3.2.2 Coho Salmon
Juvenile coho salmon (Oncorhynchus kisutch Walbaum) were collected
during the 1982 studies from Fish Creek ( RM 31.2) upstream to Jack Long
Creek (RM 144.5). Surveys conducted from February through April cap-
tured 105 fish (Appendix Table 3-A-79). Nine hundred thirty-nine
juvenile coho salmon were collected in the downstream migrant trap
during its operation from June 18 to October 12 in the Susitna River (RM
103.0) above the confluence of the Chulitna River (Appendix Table
3-B-3). Surveys of DFH sites between the Chulitna River confluence and
Devil Canyon from late May to early October collected 350 coho salmon
juveniles (Appendix Table 3-A-74). Sampling conducted in this same
reach utilizing boat-mounted electrofishing gear resulted in the col-
lection of 12 fish {Appendix Table 3-A-76). Bel.ow the confluence of the
Chulitna River, DFH site surveys collected 1,463 fish and mobile elec-
trofishing gear captured 54 juvenile coho salmon.
Overwintering coho salmon juveniles from the 1979 and 1980 brood years
were collected at numerou~ SFH sites during .February through April.
Fish were consistently recorded at Rustic Wilderness, Whiskers Creek and
Slough, Slough 6A, Slough 9, and Slough 22 during this period.
137
At least one coho salmon juvenile was collected in the downstream
migrant trap during each of the 104 days of trap operation (Figure
3-3-17). The peak catch of juvenile cohos occurred during the first
three days of operation. The high catch rate of the season was 19.5
fish per hour, recorded ,on June 18. Catch rates remained high during
the first five days of trap operation with an average of 2.5 fish per
hour, while the entire late June period trap catches averaged 1.4 fish
per hour. Small peaks in catch rate were observed for juvenile coho
salmon in the downstream migrant trap during late July, early August and
late September but average rates for each survey period following late
June remained below 1.0 fish per hour (Figure 3-3-16).
Boat-mounted e 1 ect rofi sh i ng gear and DFH site surveys conducted above
the confluence of the Chulitna River collected coho salmon juveniles
from late May through September. Major sites of collection in this
reach included Whiskers Creek and Slough, Slough 6A, and Lane Creek.
Peak catch rates for these mobi 1 e surveys occurred in 1 ate June and
September.
During the course of 1982 studies, the following samples of juvenile
coho salmon were measured for total length. One hundred five juvenile
coho salmon were measured from February through April at SFH sites. A
total of 931 coho salmon juveniles were measured from fish collected in
the downstream migrant trap. Electrofishing and DFH site surveys
between the Chulitna River confluence and Devil Canyon measured 366 fish
and these surveys conducted below the Chulitna River confluence measured
911 juvenile coho salmon.
138
a::
:::>
0 ::r
a::
LaJ a..
J: -en
w
1.0 u..
2.0
1.5
I. I
7.4Z
Figure 3-3-17. Coho salmon juveniles, downstream migrant trap catch rates averaged by
three day periods, June through October, 1982.
Scale samples from 56 (53%) of the juvenile coho salmon collected during
February through April showed that 1980 brood year fish ranged in 1 ength
from 58 mm to 116 mm during this peri ad. Fish from the 1979 brood year
ranged in length from 89 mm to 166 mm. One hundred, ten millimeters was
used as the minimum total length for 1979 brood year fish collected
during the spring surveys. Fish with a 1 ength 1 ess than 110 mm were
assigned to the 1980 brood year. Utilizing this inflection point, the
mean length for 1980 brood year coho salmon was calculated to be 83 mm
with a range in lengths from 58 mm to 107 mm. The 1979 brood year fish
had a mean length of 122 mm and a range from 110 mm to 162 mm (Table
3-3-29).
Beginning with the first captures of 1981 brood year fish in June, three
age classes of coho salmon juveniles (Age 0+, Age 1+ and Age 2+) were
present. Length frequency distribution and scale analysis were used to
determine the separation by age class for the reach of river above the
Chulitna River confluence. Below this reach, a larger overlap in the
range of lengths between age classes was apparent. Insufficient numbers
of sea 1 e samp 1 es were collected in the 1 ower reach to pro vi de an accu-
rate inflection point between age classes. However, length frequency
distribution indicated a similar separation to that observed for the
reach above the Chulitna River confluence. Table 3-3-30 presents the
results of scale analysis. on the subsample of coho salmon juveniles
collected for the entire river during the 1982 surveys.
Utilizing this data, a minimum length of 61 mm was established to
represent the smallest size of Age 1+ fish during early June. A five
140
Table 3-3-29. Coho salmon juveniles, mean length and range of lengths
by age class between Cook Inlet and Devil Canyon,
February to April, 1982.
Number
A~e I+ ..
ean Range of
Age II+
Number Mean Range of
Survey of Length Lengths of Length Lengths
Period Fish (mm) (mm) Fish (rnm) (mm)
February 7 78 68-93 '· 1 119 119
March 21 79 58-100 21 122 110-148
Apri 1 35 86 58-107. 20 123 111-162
Combined 63 83 58-107 42 122 110-162
141
Table 3-3-30. Coho salmon, scale analysis of age class composition for
juvenile fish by survey period collected between Cook
Inlet and Devil Canyon, 1982.
Age O+ Age I+ Age I I+
1981 Brood Year 1980 Brood Year 1979 Brood Year
Number Range of Number Range of Number Range of
Survey of Lengths of Lengths of Lengths
Period Fish (mm} Fish (mm) Fish (mm)
February to 0 :?8 63-116 28 89-158
May
June 1-15 0 21 85-129 15 117-202
June 16-30 3 57-59 30 71-138 3 99-118
July 1-15 0 7 79-116 0
July 16-31 4 62-71 19 72-120 0
Aug. 1-15 7 59-81 15 71-129 0
Aug. 16-31 8 58-94 15 96-137 0
Sept. 1-15 2 87-89 18 92-149 0
Sept. 16-30 21 68-95 29 102-163 1 I 192
Oct. 1-12 7 79-105 11 100-152 0
142
mi 11 imeter increase in 1 ength was attributed for each successive two-
week period. By ··he end of September, the minimum length for Age 1+
coho salmon was set at 96 mm. Length frequency and scale analysis could
not accurately provide a separation by size for Age 1+ and Age 2+ coho
salmon due to the extreme overlap of ranges. Consequently, these two
age classes were combined as Age 1+ for most length frequency calcu-
lations.
Appendix Figure 3-B-3 presents the 1 ength frequency d i st ri but ion for
juvenile coho salmon by two-week period for fish collected above the
confluence of the Chulitna River. Mean lengths and range of lengths by
two-week period for Age 0+ and 1+ coho salmon collected in this same
reach from June to October are presented in Table 3-3-31. During a
period of peak catches recorded at both the downstream migrant trap and
at DFH sites in late June, Age 0+ coho salmon had a mean length of 41 mm
with a range from 29 mm to 65 mm. The mean length had increased to 61
mm with a range from 42 mm to 95 mm during the second peak in catches
observed during September. In early October, Age 0+ coho salmon ranged
from 51 mm to 100 mm with a mean length of 72 mm.
Age 1+ and older coho salmon had a mean length during June of 103 mm
with a range from 67 mm to 202 mm. A mean length of 92 mm was observed
during July with a range from 71 mm to 150 mm. This 11 mm decrease in
mean length in July was a result of the influence of outmigrating larger
Age 2+ fish during June. The major outmigration of Age 2+ coho salmon
had occurred by early July as indicated by an increase in mean length
following this period. Analysis of scale samples collected during early
143
Table 3-3-31. Coho salmon age 0+ and age 1+ mean length and range of
lengths by survey period between the Chulitna River
confluence and Devil Canyon, June to October, 1982.
A~e 0+ Age I+
Number ean Range of Number Mean Range of
of Length Lengths of Length Lengths
Date Fish (mm} (mm) Fish (mm} (mm)
June 1-15 0 10 113 67-202
June 16-30 184 41 29-65 52 101 70-138
July 1-15 58 50 32-69 39 88 71-132
July 16-31 187 48 32-75 53 94 77-150
Aug. 1-15 161 49 34-78 11 97 81-129
Aug. 16-31 66 55 37-85 9 105 94-134
Sept. 1-15 176 57 42-90 22 121 92-149
Sept. 16-30 180 65 44-95 35 128 102-192
Oct. 1-12 46 72 51-100 11 118 105-152
144
June showed that 15 of 36 (41.7%) coho salmon in the subsample were Age
2+ fish. In 1 ate .1une there were only three Age 2+ fish out of 35 fish
sampled. No Age 2+ coho salmon were measured during July and August
although one Age 2+ fish (192 mm in total length) was collected in the
downstream migrant trap during 1 ate September. By this time, Age 1+
coho salmon had a mean length of 126 mm with a range from 102 mm to 165
mm.
Appendix Figure 3-B-4 provides the percent length frequency composition
by two-week period for juvenile coho salmon collected below the conflu-
ence of the Chulitna River. The mean 1 ength and range of 1 engths for
Age 0+ and Age 1+ coho salmon from May to September in this same reach
of river is presented in Table 3-3-32. The mean length for Age 0+ fish
collected in this reach during June was 49 mm with a range from 38 mm to
65 mm. A continued increase in mean length was observed for Age 0+ fish
in this reach and by 1 ate September, the mean 1 ength had reached 72 mm
with a range from 56 mm to 85 mm.
Age 1+ coho salmon collected below the confluence of the Chulitna River
averaged 100.9 mm during early June with a range from 61 mm to 195 mm.
Following the outmigration of larger Age 2+ fish, the mean length in
early July was 83 mm with a range from 71 mm to 102 mm. By September
Age 1+ coho salmon in this reach averaged 103 mm with a range from 92 mm
to 122 mm.
145
Table 3-3-32. Coho salmon age 0+ and age 1+, mean length and range of
lengths by survey period between Cook Inlet and the
Chulitna River confluence, May to September, 1982.
Number
A~e 0+
ean Range of Number
Age I+
Mean Range of
of Length lengths of length lengths
Date Fish (mm) (mm) Fish (mm) (mm)
May 16-31 0 2 125 119-130
June 1-15 13 49 38-59 130 101 61-195
June 16-30 59 49 35-65 78 91 67-130
July 1-15 72 54 40-70 41 83 71-102
July 16-31 126 64 47-75 82 92 76-128
Aug. 1-15 125 65 47-80 40 98 82-123
Aug. 16-31 45 67 32-85 8 113 91-137
Sept. 1-15 58 70 50-90 15 103 92-122
Sept. 16-30 16 72 56-85 2 106 101-110
146
3.2.3 Chum Salmon
Surveys conducted during 1982 collected juvenile chum salmon (Oncorhyn-
chus keta Walbaum) from Goose Creek (RM 73.1} upstream to Slough 21 (RM
142.0). Surveys conducted from March through early May collected 90
juvenile chum salmon above the Chulitna River confluence (Appe~dix Table
3-A-81). Operating in this same reach, the downstream migrant trap
captured a total of 754 chum salmon fry from June 18 to August 15
(Appendix Table 3-B-4). Surveys conducted between the Chulitna River
confluence and Devil Canyon collected 1,041 chum salmon jUveniles during
June and July at OFH sites {Appendix Table 3-A-80). Boat electrofishing
gear in this same reach collected 61 chum salmon fry (Appendix Table
3-A-81). Mobile sampling surveys conducted be 1 ow the confluence of the
Chulitna River captured 133 juvenile chum salmon from June to early
September {Appendix Table 3-A-81).
The percent of total chum salmon fry captured by an collection tech-
niques by two-week period and by reach of river between Cook Inlet and
Devil Canyon is presented in Figure 3-3-18. Over 85 percent of the
total captures of juvenile chum salmon during 1982 were recorded during
June.
Sixty-seven percent (505 fish) of the total captures of chum salmon fry
in the downstream migrant trap occurred during 1 ate June (Figure 3-3-
19). The average catch rate for this period was 3.7 fish per hour. The
peak catch rate of 10.0 fish per hour was recorded on June 21, three
days after initial trap deploymenL A decrease in catch rate was
147
u..
0
1-z
UJ u a::
60
50
• CHULITNA TO DEVIL .CANYON
fZl COOK INLET TO CHULITNA
UJ 20 a.
10
JUNE
r-15
JUNE
16-30
JULY JULY AUGUST AUGUST SEPT.
1-1!5 16-31 I-I ti 18-31 I• IS
SURVEY PERIOD
SEPT.
18-30
Figure 3-3-18. Chum salmon juveniles, percent of total catch by all gear types
including smolt trap by reach of river averaged by two week period on
the Susitna River between Cook Inlet and Devil Canyon, 1982.
5
0::
::::>
04 I
' I en
lL
3
2
JUNE JULY AUGUST
Figure 3-3-19. Chum salmon juveniles, downstream migrant trap catch
rates avr>raged by three day periods, Llune through August,
1982.
149
observed during early July and 87 percent of the total chum salmon fry
collected in the trap were recorded by July 15. This is the latest
period during which chum salmon fry were collected at DFH sites above
the Chulitna River confluence.
The downstream migrant trap catch rate for chum salmon fry dropped below
0.1 fish per hour by the end of July, and only ten fish were collected
during early August. The last capture of chum salmon fry above the
Chulitna River confluence was recorded August 15 (Figure 3-3-16).
Boat electrofishing gear and surveys of DFH sites below the confluence
of the Chulitna River during 1982 collected chum salmon fry from June
through early August. About 50 percent of the total captures of chum
salmon fry in this reach occurred in early June.
Ninety newly emerged chum salmon juveniles collected above the Chulitna
River confluence were measured for tot a 1 1 ength from February through
April. A total of 569 chum salmon fry were measured from fish collected
in the downstream migrant trap. Two hundred sixteen fish were measured
at DFH and SFH sites above the Chu 1 itna River confluence and 113 fish
were measured at sites below the Chulitna River confluence. All captur-
ed chum salmon fry were from the 1981 brood year and were Age 0+.
Chum salmon fry collected during March still had yolk sacs present, but
most fish had reached the buttoned-up stage by April. The mean length
of chum salmon fry following yolk sac absorption was approximately 35 mm
during March and April, with a range from 29 mm to 41 mm.
150
The percent 1 ength frequency composition by two-week period for chum
sa 1 man fry co 11 ecte·~ above the Chu 1 itna River confluence is presented in
Appendix Figure 3-B-5. Mean total length and range of lengths by survey
period for chum salmon fry captured by the combined sampling efforts for
the reaches of river above and below the Chulitna River confluence are
presented in Table 3-3-33.
Calculated mean lengths for chum salmon fry collected above the Chulitna
River confluence ranged from 34 mm in March to 42 mm in early July, an
increase of 9 mm during the survey period. No appreciable change in
mean length was observed following the early July survey but a seven
millimeter increase in the upper limit of the range was observed by late
July. Insufficient numbers of fry were collected during early August to
provide a representative mean length for this period.
Appendix Figure 3-B-6 provides the percent length frequency composition
by two-week period for chum salmon fry collected below the Chulitna
River confluence. Chum salmon fry collected in this reach had a mean
total length of 43 mm in early June with a range from 29 mm to 51 mm.
' By the end of June they had reached a mean 1 ength of 45 mm with a range
from 34 mm to 54 mm. The nine fish measured in this reach after late
June had a mean length of 43 mm and a range from 30 mm to 50 mm.
A mean length of 40 mm with a range from 30 mm to 52 mm was recorded for
chum salmon fry during the peak catches above the Chulitna River conflu-
ence during June. The peak catches in the lower reach during this same
151
Table 3-3-33. ChUI\1 s1;1lmon. fry, mean length and range of lengths by
survey period and by reach of river, March to September,
1982.
Cook Inlet to Chulitna Chulitna to Devil Can~on
Number Mean Rctnge of Number Mean Range of
Survey of Length Lengths of Length Lengths
Period Fish (mm) (mm) Fish (mm} (m~
March 0 6 34 30-36
Apri 1 0 37 38 35-42
May 0 45 40 37-43
June 1-15 60 43 29-51 97 40 30-52
June 16-30 44 45 33-54 423 36 28-52
July 1-15 3 43 36-49 161 42 29-55
July 16-31 2 48 45-50 92 42 30-62
Aug. 1-15 1 39 39 10 41 37-46
Aug. 16-31. 0 0
Sept. 1-15 1 30 30 0
152
period were comprised of chum salmon fry with a mean length of 43 mm and
ranged from 29 mm t~ 54 mm.
3.2.4 Sockeye Salmon
Sockeye salmon juveniles (Oncorhynchus nerka Walbaum) were observed from
a small tributary entering Kroto Slough (RM 38.5} to Slough 21 (RM
142.0) during 1982. Surveys conducted from March through early May.
between the Chulitna River confluence and Devil Canyon resulted in the
collection of 19 juvenile sockeye salmon (Appendix Table 3-A-83). The
downstream migrant trap captured 2,134 sockeye salmon while in operation
above the Chulitna River confluence from June .18 to October 12 {Appendix
Table 3-B-5). Designated fish habitat surveys conducted between the
Chulitna River confluence and De vi 1 Canyon from June through October
collected 1,308 juvenile sockeye salmon (Appendix Table 3-A-82) and 15
fish were collected by boat-mounted electrofishing gear. Mobile sampl-
ing techniques collected 130 juvenile sockeye salmon at sites below the
confluence of the Chulitna River (Appendix Table 3-A-83).
One 1980 brood year sockeye salmon (Age 1+) was collected at Slough 9
during March. Eggs and alevins from the 1981 brood class were observed
at Slough 11 and Slough 21 during the same period. Post-emergent
sockeye salmon fry were collected at Sloughs 8A, 11, and 21 during early
May.
In early June, surveys of DFH sites above the Chulitna River confluence
collected 223 sockeye salmon juveniles at Slough 6A and one fish at
153
Slough 8A. By late June, sockeye salmon juveniles were observed at
numerous sites including Sloughs 6A~ 9, 11, and 19.
The downstream migrant trap catch data averaged by three-day periods is
presented in Figure 3-3-20. The downstream migra~t trap collected 190
juvenile sockeye salmon during late June. The average catch rate for
this period was 1.4 fish per hour and the highest catch was 3.2 fish per
hour recorded on June 21. The highest overall catch rates for juvenile
sockeye salmon in the downstream migrant trap occurred during early July
when an average catch rate of 4.4 fish per hour was recorded and a peak
catch rate of 16.3 fish per hour occurred July 7. By 1 ate July, trap
catches averaged 1.9 fish per hour with a peak catch rate of 6.1 fish
per hour on July 26.
The average catch rate of juvenile sockeye salmon in the trap dropped
below one fish per hour during early August and averaged less than 0.1
fish per hour after late August. The last captures of juvenile sockeye
salmon were recorded October 11 (Figure 3-3-16).
Mobile electrofishing gear and DFH site surveys collected sockeye salmon
juveniles from early June through late September at sites located below
the confluence of the Chulitna River (Appendix Tables 3-A-82 and 3-A-
83). Peak catches for this species in the lower reach were recorded
during July.
Nineteen juvenile sockeye salmon captured between the Chulitna River
confluence and Devil Canyon were measured for total length from March
154
........
tTl
tTl
a:
=> 0
J:
.......
:I: en
u..
JUNE I JULY AUGUST SEPTEMBER :OCTOBER
Figure 3-3-20. Sockeye sAlmon juveniles, downstream migrant trap catch rates averaged by
threP day periods, June through October, 1982.
through early May. A total of 2,122 sockeye salmon collected in the
downstream migrant trap were measured, and 697 fish captured by mobile
sampling techniques in this same reach of river from June through
October were measured. One hundred four juvenile sockeye salmon col-
lected at sites located below the Chulitna River confluence were mea-
sured.
Scale analysis and comparisons of the length frequency distribution
showed the presence of both Age 0+ and Age 1+ (brood years 1981 and
1980, respectively) sockeye salmon in the Susitna River (Table 3-3-34).
A separation by age classes showed that a total of 2,910 {98.9%) Age 0+
and 32 (1.1%) Age 1+ sockeye salmon juveni1es were measured for total
length.
Mean total length and range of lengths by survey period for Age 0+ and
Age 1+ sockeye salmon captured by the combined studies above the Chu-
. litna River confluence are presented in Table 3-3-35. The percent
1 ength frequency for juveni 1 e sockeye sa 1 mon call ected between the
Chulitna River confluence and Devil Canyon by two-week period is pre-
sented in Appendix Figure 3-8-7. Surveys conducted from March to early
l\1ay collected post-emergent Age 0+ sockeye salmon having a mean length
of 38 mm with a range from 29 mm to 37 mm. A mean length of 42 mm with
a range from 27 rnm to 63 mm was observed for Age 0+ fish collected
during late June between the Chulitna River confluence and Devil Canyon.
During the period of peak catch rates observed in the downstream migrant
trap during early July, Age 0+ fish had a mean length of 42 mm with a
range from 30 mm to 74 mm. A mean length of 45 mm with a range of 28 mm
156'
Table 3-3-34. Sockeye salmon, scale analysis of age class composition
for juvenile fish by survey period collected between Cook
Inlet and Devil Canyon, 1982.
Age 0+ Age 1+
1981 Brood Year 1980 Brood Year
Number of Range of Lengths Number of Range of Lengths
Survei: Period Fish (mm) Fish (mm)
Feb.--May 0 0
June 1-15 0 17 57-120
June 16-30 4 51-63 1 72
July 1-15 3 60-74 0
July 16-31 20 51-86 0
Aug. 1-15 15 68-90 0
Aug. 16-31 4 68-84 0
Sept. 1-15 0 0
Sept. 16-30 8 70-82 0
Oct. 1-12 9 72-8~ 0
157
Tab 1 e 3-3-35. Sockeye sa 1 mon age 0+ and age 1 +, mean 1 ength and range
of lengths by survey period between the Chulitna River
confluence and Devil Canyon, 1982.
A~e 0+ Age 1+
Range of Number ean Range of Number Mean
Survey of Length Lengths of Length Lengths
Period Fish (mm} (mm} Fish (mm} (mm}
March-May 18 33 29-37 1 57 57
June 1-15 1 30 30 23 77 62-88
June 16-30 266 42 27-63 1 72 72
July 1-15 998 42 30-74 1 93 93
July 16-31 818 50 24-84 2 87 86-87
Aug. 1-15 348 51 28-90 0
Aug. 16-31 94 48 29-84 0
Sept. 1-15 82 51 29-75 0
Sept. 16-30 72 59 34-82 0
Oct. 1-12 15 72 48-87 0
158
to 79 mm was observed for Age 0+ fish captured by mobile sampling.gear
during the peak cai-::h rates recorded for these gear types in July. Mean
lengths of Age 0+ sockeye salmon collected by all gear types above the
Chulitna River confluence increased to 59 mm with a range from 34 mm to·
82 mm during late September. The fourteen sockeye salmon juveniles
collected during early October ranged in length from 48 mm to 87 mm with
a mean length of 71 mm.
The .percent length frequency distribution by two-week period for juve-
nile sockeye salmon collected below the Chulitna River confluence is
presented in Appendix Figure 3-B-8. Age 0+ sockeye salmon in this reach
had a mean length of 41 mm in early July with a range from 30 mm to 65
mm and had increased to a mean length of 62 mm with a range from 40 mm
to 91 mm during September (Table 3-3-36).
Age 1+ sockeye salmon rangedin length from a 57 mm fish captured during
March to a fish 120 mm in length collected during the peak migration of
Age 1+ fish in June. The mean length fqr Age 1+ sockeye salmon recorded
during this period for the combined samp-Jing reaches was 80 mm with a
range of 62 mm to 120 mm. The last recorded capture of Age 1+ sockeye
salmon during 1982 was on July 27 in the downstream migrant trap ..
3.2.5 Pink Salmon
A total of 28 pink salmon fry (Oncorhynchus gorbuscha Walbaum) were
collected from May to 1 ate July, 1982. Surveys conducted during 1 ate
May accounted for 71.4 percent of the tota 1 captures and 21.4 percent
159
Table 3-3-36. Sockeye salmon age 0+ and age 1+ mean length and range of
lengths by survey period below the Chulitna River
confluence, June through September, 1982.
AGE 0+ AGE 1+
1981 Brood Year 1980 Brood Year
Number Mean Range of Number Mean Range of
Survey of Length Lengths of Length Lengths
Period Fish (mm) (mm} Fish {mm) (mm}
June 1-15 1 33 33 4 99 81-120
June 16-30 2 45 41-49 0
July 1-15 36 41 30-65 0
July 16-31 12 57 40-80 0
Aug. 1-15 7 52 49-65 0
Aug. 16-31 11 55 34-78 0
Sept. 1-15 19 61 40-91 0
Sept. 16-30 3 67 41-87 0
160
were collected in the downstream migrant trap during July (Appendix
Table 3-B-6). The last capture of pink salmon fry was recorded July 24
at Slough 11 (RM 135.3).
Table 3-3-37 presents the mean length and range of lengths by site for
pink salmon fry collected during the 1982 surveys. Pink salmon fry had
a mean length of 36 rnm with a range from 29 rnm to 43 rnm. All pink
salmon juveniles captured were from the 1981 brood year.
3.3 Food Habits of Juvenile Salmon
3.3.1 Salmonid Collections
Total numbers of chinook, coho, and sockeye juveniles captured during
1982 sampling were 313, 171, and 116, respectively (Table 3-3-38).
Numbers of these juveniles retained for laboratory analysis were 279,
113, and 116 respectively. Large numbers of chinook salmon juveniles
salmon juveniles were captured at Slough 21 ~nd ·Indian River. Substan-
tial numbers of coho salmon juveniles were captured at Fourth of July
Creek, Slough 8A, and Indian River. Most sockeye salmon juveniles
captured were from Slough 11, though they were also found at Slough 8A.
3.3.2 Important Food Types
All three salmon species collected during this study consumed both
terrestrial and aquatic invertebrates (Appendix Tables 3-C-1 to 3-C-3).
Midges (Diptera: Chironomidae) were the numerically dominant taxa in
161
Table 3-3-37. Pink salmon fry collection by site for the combined
studies, 1982.
Site Surve:ted
Mainstem opposite
Sunshine Camp
Rabideux Creek
Birch Creek Slough
Downstream Migrant
Trap
Mainstem at Curry
Camp
Slough 11
TOTAL -ALL SITES
River
Mile
79.0
83.1
88.4
103.0
120.7
135.3
Date
May 25
May 25
May 25
July 3-17
July 7
July 24
May 25 to
July 24
162
Number
of Mean RanJe Fish Length (mm) (mm
3 42 41-42
1 43 43
16 35 35
6 34 29-37
1 36 36
1 35 35
28 36 29-43
Table 3-3-38. Numbers of juvenlle,salmon captured and retained
from six Designated Fish Habitat st"tes In the upper reach of the
Susitna River In August and September, 1982.
Chinook Coho Sockeye
Location Captured Retained Cap"tured Retained Captured Retained
Slough 8A 27 17 51 40 24 24
S I oug h 11 19 19 3 3 87 87
Slough 20 39 39 0 0 0 0
Slough 21 86 86 2 2 3 3
4th July Crk 84 74 68 37 0 0
Indian River 58 44 47 31 0 0
163
the stomach contents of chinook, coho, and sockeye salmon juveniles and
were consumed as larvae,· pupae, and adults (Figures 3-3-21 to 3-3-31).
Larvae of other dipterans .(Simuliidae, Psychodidae, and Tipulidae) were
also present in many stomach samples. All three salmon species occa-
sionally consumed mayfly (Ephemeroptera) and stonefly (Plecoptera)
nymphs of various families. Sockeyes captured at Slough 11 and Slough
8A in August had large numbers of copepods and cladocerans in their
stomachs.
All of the analysis was done in terms of numbers, not volume. Chiro-
nomids are dominant numerically, but they are physically small in
comparison to mayfly and stonefly nymphs, tipulid larvae (Diptera:
Ti pul i dae), and many other invertebrates found in the system. As a
result, chironomids may not be as important in terms of their volumetric
contribution.
3.3.3 Comparisons Between Species
Chi-square tests comparing the stomach contents of the salmon species
showed that differences between proportions of invertebrate types in
coho and sockeye stomachs were usually significant (p ( 0.05). Refer to
Appendix Tables 3-C-4 to 3-C-23 for a listing of proportions used in
chi -square test. Invertebrate taxa with less than five individuals
found in all salmon species were not included in these analyses.
Significant differences were also found among coho, chinook, and sockeye
when they occurred together (p ( 0.05) (Table 3-3-39). In some samples
coho and chinook were also shown to have
164
other
torrestrial
Aug. 6,1982
92%Chlronomldat. larvae
other aquatic
Aug •. 25,1982
2'111
other aquatic
Figure 3-3-21. Stomach contents of chinook salmon juveniles collected in
Slough, 8A. during August, 1982. Percent composition is
based on numbers of individ~als.
165
Aug.24, 1982
73%
Chironomldae larvae
Chironomldae
pupao & adults
Sept.20, 1982
Sapt.5,1982
2%
other
aquatic
Figure 3-3-22. Stomach contents of chinook salmon juveniles collected in
Slough 11 during August and September, 1982. Percent
composition is based on numbers of individuals.
166
Aug.7,1982
Empldldae
adults
Sept.6, 1982
other
.aquatic
Aug.27 ,1982
other
aquatic
Empidldae
adults
Sept.21,1982
Figure 3-3-23. Stomach contents of chinook salmon juveniles collected in
Slough 21 during August and September, 1982. Percent
composition is based on numbers of individuals.
167
Aug.S, 1982
Chironomidae
larvae
Aug.28, 1982
Chlronomidae
p.upae .& adults
Sept.8, 1982
Chironomidae
pupae & adults
Figure 3-3-24.
hironomidae
pupae &
adults
small t<2mm)
Plecoptera
nymphs
Sept.22, 1982
Stomach contents of chinook salmon juveniles collected in
Fourth of July Creek during August and September, 1982.
Percent composition is based on numbers of individuals.
168
Aug.8,1982
terrestrial
Sept.9, 1982
Chlronomidae
pupae & adults
terrestrial
Aug.29, 1982
terrestrial
Chironomidae
larvae
Sept.23, 1982
Chironomidae
pupae & adults
Figure 3-3-25. Stomach contents of chinook salmon juveniles collected in
Indian River during August and September, 1982. Percent
composition is based on numbers of individuals.
169
other
aquatic
Aug.6,1982
Sept. 7, 1982
terrestrial
Aug.25,1982
Sept.22,1982
other aquatic
Figure 3-3-26. Stomach contents of coho salmon juveniles collected in
Slough 8A during August and SeptP.mber, 1982. Percent
composition is based on numbers of individuals.
170
Sept.6, 1982
Sept.20, 1982
Figure 3-3-27. Stomach contents of coho salmon .iuveniles collected in
Slough 11 during September, 1982. Percent composition is
based on numbers of individuals.
171
Aug.5,1982
Chironomidae
pupae & adults
Sept.8, 1982
Aug. 28,1982
Chironomldae
pupae & adutts
Sept.22,1982
24%
other
aquatic
Figure 3-3-28. Stomach contents of coho salmon juveniles collected in
Fourth of July Creek during August and September, 1982.
Percen~ composition is based on numbers of individuals.
172
Aug .. 8,1982
7%
Chlronomldae
pupae & adults
Chlronomidae
pupae & adults
Aug.29, 1982
other aquatic
Sept.23,1982
Figure 3-3-29. Stomach. contents of coho salmon juveniles collected in
Indian River during August and September, 1982. Percent
composition is based on numbers of individuals.
173
Aug.6,1982
Sept.7,1982
Chironomidae
pupae & adults
terrestrial
Aug.25,1982
Sept.22,1982
other aquatic
Figure 3-3-30. Stomach contents of sockeye salmon juveniles collected in
Slough 8A during Auqust and September, 1982. Percent
composition is based on numbers of individuals.
174
Aug.3, 198:2
1~ ffiiSC.
2% Chironomidae
pupae & adults
Sept.5,1982
1%
misc.
Aug.24, 1982
88% Cladocera
2 % Chironomidae
Chironomidae larvae
pupae & adults
Sept.20, 1982
84% Chironomidae
pupae & adults
Figure 3-3-31. Stomach contents of sockeye snlmon juveniles collected in
Slough 11 during August and September, 1982. Percent
composition is based on numbers of individuals.
175
Table 3-3-39. Results of chi-square analyses, comparing percent
composition of major Invertebrate taxa In stomach contents of co-
occuring species of salmonid juveniles. H0 : proportions of Inverte-
brate taxa are the same In alI species Is tested at the 95% confidence
level. Chi-square (X2) values, and degrees of freedom for testing
(OF) are shown. Numbers In parenthesis are samples sizes (total
number of Invertebrates used for the test ln each species).~
Site
Slough 8A
Slough 8A
Slough 8A
Slough 8A
Slough 8A
Slough 11
Slough 11
Slough 11
Date Species compared x2 OF Test Results
82/08/06 Chinook-Coho 70 2 Reject H0
(165) (41)
82/08/25 Chinook-Coho 81 5 Reject H0
(51) (134)
82/08/25 Coho-Sockeye 77 10 Reject H0
(134) (74)
82/09/07 Coho-Sockeye 30 4 Reject H0
(150) (19)
82/09/22 Coho-Sockeye 24 8 Accept H0
( 141) (65)
82/08/24 Chinook-Sockeye 3 3 Accept H0
(22) (104)
82/09/05 Chinook-coho-Sockeye 236 6 Reject H0
(138) (46) (676)
82/09/20 ChI nook-Coho-Sockeye 64 6 Reject H0
(9) (95) (98)
4th of July Crk 82/08/05
4th of July Crk 82/08/28
4th of July Crk 82/08/28
4th of July Crk 82/09/22
Chinook-Coho
(129) (70)
ChI nook-Coho
( 45) ( 1 23)
Chinook-Coho
05 9) ( 1 51 )
ChI nook-Coho
(91) (14)
8 6 Accept H0
57 5 Reject H0
34 15 Reject H0
8 8 Accept H0
Indian River
Indian River
I n d I an R I v er
Indian River
82/08/08
82/09/29
82/09/29
82/09/23
Chinook-Coho
(216) (28)
Chinook-Coho
(22) (725)
Chinook-Coho
(257) (304)
Chinook-Coho
(76) (72)
7
222
147
18
7 Accept H0
4 Reject H0
8 Reject H0
4 Reject H0
.sV When fIsh were collected In more than one area at a site, separate
comparisons were done for each collection.
similar stomach contents, but more often there were significant differ-
ences in inverteb;ate taxa .consumed by the two species (p <. 0.05).
These differences, however did not follow any perceivable pattern. No
one invertebrate, taxa or group of taxa was consistently used more
heavily by either species.
3.3.4 Electivity Indices
El ectivity indices, which compare the proportion of each invertebrate
type in the drift samples to their proportion in the stomach contents,
usually showed positive selection for Chironomidae larvae in all three
salmon species (Appendix Tables 3-C-4 to 3-C-23). An exception to the
above was for sockeye salmon at Slough 11 in late August. At this time
the sockeyes were feeding heavily on copepods and cladocerans, and were
not consuming large numbers of chironmid larvae. Since almost no
cladocerans or copepods were caught on that date in the drift net, the
electivity values for them in those sockeyes examined were significantly
positive (Appendix Table 3-C-22).
3.3.5 Drift Samples Compared to Kick Screen Samples
Four families of Ephemeroptera, and five families each of Di ptera,
Plecoptera, and Trichoptera (caddis flies) were identified in the drift
and kick screen samples (Appendix Tables 3-C-24 and 3-C-25).
' ' Since time and budget constraints limited the sorting and identification
of invertebrates from kick screen sarnples, only those from 1 ate August
177
and early September were analyzed. Chi-square tests indicated that the
proportions of invertebrate taxa collected concurrently by kick screen
and drift nets were significantly different (p< 0.05) (Table 3-3-40).
The drift samples usually contained fewer Chironomidae larvae, and more
adult dipterans and other terrestrials than the kick screen samples
(Figures 3-3-32 to 3-3-40).
3.3.6 Comparison of Invertebrate Populations at Different
Sites
Drift samples from the· tributary sites (Fourth of July Creek and Indian
River) were compared by chi-square analysis to determine if the
proportions of invertebrate types differed between sites. The analysis
showed that on a 11 dates these proportions were not the same ( p <. 0. 05)
(Table 3-3-41).
The same test was conducted comparing drift samples from the sloughs.
These chi-square tests indicated that there were significant differences
between proportions of invertebrate taxa in the sloughs (p( 0.05) (Table
3-3-41). Since few invertebrates were collected in the drift samples at
Slough 11 in early September, and at Slough 8A in late September, those
samples were not included in the analysis.
A chi-square test was used to determine if the proportion of all indi-
viduals occurring in each taxa was the same for both tributaries and
sloughs. Samples from all sloughs were combined in one group and
178
Table 3-3-40. Results of chi-square analyses comparing porportions
of invertebrates collected in drift net and kick screen samples,
where H0 : proportions of Invertebrate taxa collected are the same
In both methods, Is tested at the 95% confidence level. Degrees of
freedom for testing CDF), and the chi-square values <X2) are also
given. .W
Date Samples Ccmpared Test. Results OF x2
82/08/24 drift from sloughs
to and Reject H0 18 1 ,566
82/09/29 kick screen from sloughs
82/08/24 drift from tributaries
to and Reject Ho 19 1,177
82/08/29 kick screen from tribs.
82/09/05 drift from sloughs
to and Reject H0 25 1, 750
82/09/09 kick screen from trlbs.
82/09/05 drift from sloughs
to and Reject H0 19 2,478
82/09/09 kick screen from tribs.
~ Ta?<a with less than five Individuals found at all sites were
not used In anlayses.
179
.......
OJ
0
100 100.
75 Aug.6,1982 75 Sept.7.1982
50 50
,. 25 25 u c: ..
::J
r:l
·~ ...
E
0
~ 100 .. 100
a..
75 Aug.25,1982 75 Sept.22. 1982
50 50
25
Major Invertebrate Types Major Invertebrata Typea
Figure 3-3-32. Percent frequency of major invertebrate types found in drift net samples
taken in Slough 8A during August and September, 1982. Percent frequency
was calculated using numbers of individuals and is given for those types
representing over two percent of the total.
I-' co
I-'
-c ..
" 1 ;
Q.
Aug.3,1982 Sept.5,1982
Aug.24,1982 Sept.20, 1982
Major Invertebrate Types Major Invertebrate Types
Figure 3-3-33. Percent frequency of major invertebrate types found in drift net samples
taken in Slough 11 during August and September, 1982. Percent frequency
was calculated using numbers of individuals and is given for those types
representing over two percent of the total.
...... co
N
100 100
Aug.4,1982 Sept.8,1982
75 75
50 50
...
IJ 25 c:
Gl
::l a
ill
.t
c ..
IJ
~ 100 100
Aug.26, 1982 Sept.21, 1982
75 75
50 50
25
Major Invertebrate Types Major Invertebrate Types
Figure 3-3-34. Percent frequency of major invertebrate types found in drift net samples
taken in Slough 20 during August and September, 1982. Percent frequency
was calculated using numbers of individuals and is given for those types
representing over two percent of the total.
~ co w
100
75 Aug.7,1982 75 Sept.6, 1982
50 50
... 25 25
u c
ill
:1 .,.
ill
II.
c
ill
u 100 100 .. c.
75 Aug.27 ,1982 75 Sept-21,1982
50 so
Major Invertebrate Types Major nvertebrate Types
Figure 3-3-35. Percent frequency of major invertebrate types found in drift net samples
taken in Slough 21 during August and September, 1982. Percent frequency
was calculated using numbers of individuals and is given for those types
representing over two percent of the total.
1--'
00 .p:.
100 100
75 Aug.5,1982 75 Sept.8,1982
50 50
,..
" 25 25 <: ..
"'· a .. .:
c ..
" .. 100 lL
75 Aug.28, 1982
Sept. 22,1982
75
50 50
25 25
Major Invertebrate Types Major Invertebrate Types
Figure 3-3-36. Percent frequency of major invertebrate types found in drift net samples
taken in Fourth of July Creek during August and September, 1982. Percent
frequency was calculated using numbers of individuals and is given for
those types representing over two percent of the total.
1-' co
(J1
Aug.8,1962 Sept.9,19B2
Aug.29,19B2 Sept.23, 1982
Major Invertebrate Types Major Invertebrate Types
Figure 3-3-37. Percent frequency of major invertebrate types found in drift net samples
taken in Indian River during August and September, 1982. Percent frequency
was calculated using numbers of individuals and is given for those types
representing over two percent of the total.
100 100
Slough 8A m--Slough 11
Aug.25, 1982 Aug.24,1 g82
75 75
50 50
,. 2 25 " c .,
~ a .,
~
E .,
" Qj
D. Slough SA Slough 11
SepL7,1982 Sept.5, 1 982
Major Invertebrata Types MaJor hvertabrata Types
Figure 3-3-38. Percent frequency of major invertebrate types found in kick screen samples
taken in Slough 8A and Slough 11 during August and September, 1982.
Percent frequency was calculated using numbers of individuals and is given
for those types representing over two percent of the total.
Major Invertebrate Types Major Invertebrate Types
Fiqure 3-3-39. Percent frequency of major invertebrate types found in kick screen samples
taken in Slough 20 and Slough 21 during August and September, 1982.
Percent frequency was calculated using numbers of individuals and is given
for those types representing over two percent of the total.
...... co co
75
50
c
<II
~ 100
Ill a.
75
4th of July Creek
Aug.28, 1982
4th of July Creek
Sept.8, 1982
Major Invertebrate Typoa
lndien River Mouth
Aug.29, 1982
Indian River Mouth
Sept.9,1 g82
MaJor Invertebrate Type•
Figure 3-3-40. Percent frequency of major invertebrate types found in kick screen samples
taken in Fourth of July Creek and Indian River during August and September,
1982. Percent frequency was calculated using numbers of individuals and is
given for those types representing over two percent of the total.
Tab I e 3-3-41. Results of chi-square analyses comparing
percent composition of invertebrate taxa in drift samples.
H0 : proportions of invertebrate taxa are the same at al l
sites fs tested at the 95% confidence level. Degrees of
freedom for testing (Of), and chi-square values (X2) are
also shown. ~
Date S ltes Compared Test Results OF x2
82/08/05 4th of July Creek
and Accept H0 1 2 23
82/08/08 Indian River
82/08/06 Slough 8A
82/08/07 Slough 21 Reject H0 26 661
82/08/04 Slough 20
82/08/28 4th of July Creek
and Reject H0 1 1 57
82/08/29 Indian River
82/0S/ 25 Slough SA
82/08/24 Slough 11 Reject H0 20 422
82/08/26 Slough 20
82/09/0S 4th of July Creek
and Reject H0 10 11 0
82/09/09 Indian River
S2/09/07 Slough SA
and Reject H0 1 4 219
82/09/0S Slough 20
82/09/22 4th of July Creek
and Reject H0 13 194
82/09/23 Indian River
82/09/20 Slough 1 1
and Reject H0 9 335
82/09/21 Slough 20
82/08/03 Tributaries
to and Reject H0 13 155
82/0S/08 Sloughs
82/08/24 Tributaries
to and Reject H0 14 135
82/08/29 Sloughs
189
Tab I e 3-3-41 . concluded.
Date Sites Compared Test Resu Its Df x2
82/09/05 Tributaries
to and Reject H0 17 257
82/09/09 Sloughs
82/09/20 Tributaries
and Reject H0 . 15 290
82/09/23 Sloughs
iJ/ Taxa with less than five Individuals found at all sites
were not used In analyses. Slough 11 in early September,
and Slough BA In late September were not Included in this
analysis due to smal I sample sizes {115 and 22 respectively).
190
samples from all tributaries in another group for each date. The
results demonstrat,~d that the invertebrate populations were not the
same. The proportions of invertebrate taxa in the sloughs and tribu-
taries were significantly different on every date sampled.·
191
4. DISCUSSION
4.1 Distribution and Abundance
4.1.1 Resident Fish Species
4.1.1.1 Rainbow Trout
Rainbow trout were distributed throughout the Susitna River below Devil
Canyon but were most commonly captured at tributary sites on the Susitna
River above the Chulitna River confluence. Most adult rainbow trout
move into the mainstem Susitna in September from clear water tributaries
and then remain there u~til after breakup when they move back into their
natal tributary to spawn. After spawning occurs, the adults are fairly
sedentary until September. Adults also make use of many clear water
sloughs in the Susitna River above the Chulitna River confluence during
the summer. Most juvenile rainbow trout are believed to rear in the
tributaries but a few make use of tributary mouths ·and clear water
sloughs.
Distribution and Relative Abundance
Rainbow trout were captured in both 1981 and 1982 at all of the 12 DFH
sites that were sampled in both years (ADF&G 1981c). The general dis-
,tribution of catches was also similar during both years at these 12 DFH
sites. In general, catches of rainbow trout were highest at tributary
mouths such as 4th of July Creek and at clear W!lter sloughs such as
192
Slough 8A. Catches at all DFH sites were typically higher in June and
September than in July and August. Most rainbow trout probably move
well up into the tributaries in July and August.
In the reach of river between the Chulitna River confluence and Devil
Canyon, catch data indicate that some rainbow trout inhabit clear water
sloughs during the summer. Rainbow trout were documented to occur
during July and August at all the DFH slough sites above the confluence,
as well as Slough 10 (RM 133.8) and Slough 22 (RM 144.3). Populations
within these sloughs are of unknown size but are probably small in
comparison to tributary populations.
Boat electrofishing catch per unit effort (CPUE) for rainbow trout
varied greatly over the season and between tributary or slough and
mainstem sites in 1982 (Figure 3-4-1). Rainbow trout CPUE's were also
usually greater in the Susitna River aboVe the Chulitna River confluence
in comparison to sites located below the confluence. In general, CPUE's
were greater at tributary or slough 'Sites rather than in the mainstem.
CPUE's in late May, June, and late September were higher than in July
and August, indicating definite seasonal trends in abundance.
Adult Movement and Migration Patterns
Recapture data and observations of the radio tagged fish suggest that
rainbow trout are relatively nonmigratory and inhabit relatively short
sections of the Susitna River. Similar results are cited by McPhail and
Lindsey (1970) and Morrow ( 1980).
193
20
15
(\1
'o -
)(
1.1.1
f-10 =>
~
::E
a:
1.1.1
CL
:t: 5
u
f-
<t u
0
8
7
(\1
'o 6
)(
1.1.1
f-5
=> z
::E 4
a:
1.1.1 :3 CL
:t:
u 2
1-
<t u
0
I
0
I
CHULITNA RIVER (RM 98.5) CONFLUENCE
TO DEVIL CANYON
0 Tributary or Slough Sites
• Mainstem Sites
COOK INLET TO, CHULITNA RIVER
[RM 98.5) CONFLUENCE
D Tributary or Slough Sites
II Moinstem Sites
a .,
; ~ oo
0 0 z z
I
0
I
I
0
I
a o
~ ~
" " 0 0
0 0 z z
1•15 16<30 1·15 16•30
JUNE SEPTEMBER
Figure 3-4-1. Rainbow trout catch per unit of boat electrofishing
effort at tributary and mainstem sites on the Susitna
River between Cook Inlet and Devil Canyon, May to
September, 198?.
194
Evidence that rainbow trout in the Susitna River remain in a relatively
small range is ind~cated by examining 12 tag recoveries made in 1982 of
fish tagged in 1981. During the interim overwintering, only three of
these recaptured fish were found more than five miles from the site of
tagging. Five of the fish were recaptured in the same location where
tagged.
Rainbow trout, however, do exhibit seasonal migrations. A rainbow trout
that was tagged and recaptured during 1981, moved 34.5 river miles
downstream. Recapture data and catch per unit effort data indicate that
rainbow trout begin to out-migrate from tributaries in September,
overwinter in the Susitna River in the proximity of the mouth of their
natal tributary, and then migrate back to that tributary in May.
Ra·inbow trout are relatively sedentary during the winter months and
inhabit the mainstem. The five radio tagged rainbow trout monitored
during the winter moved a maximum of 23.3 miles, and one fish was later
captured in May only 0.6 miles from where it was originally captured and
tagged. Three of the fish, however, increased movements for unknown
reasons between early December and mid-January after remaining in
approximately the same location for 45 days (Figure 3-3-1).
Winter sampling efforts did not recapture the radio tagged fish, how-
ever, four other adult rainbow trout were captured in the vicinities of
the tagged fish. These fish were captured with relatively little effort
in comparison to other winter sampling which captured only two other
adult rainbow trout although much more effort was expended. Indications
195
are that rainbow trout inhabit areas with specific habitat characteris-
tics during the winter months in the Susitna River.
Spawning
Limited catches of mature adult rainbow trout indicate that rainbow
trout probably spawn between late May and June in tributaries of the
Susitna River. By early July, all adult rainbow trout captured and
necropsied at sites on the Susitna River had spawned.
Juvenile Rearing Areas
Catches of juvenile rainbow trout have been very 1 imited and therefore
most juveniles are believed to rear in the upper reaches of clear water
/
tributaries. Juveniles have been captured at most-of the tr-ibutary and
·slough mouths where adult catches were high. Use of the mainstem is
very limited, only six juvenile rainbow trout were captured in the
downstream migrant trap. No major seasonal differences in catch or
distribution of juvenile rainbow trout have been noted. During the ice
covered months, juveni 1 es have been captured only at Slough 10 (RM
135.3} and Slough 22 (RM 144.3). McPhail and Lindsey (1970) report that
stream dwelling juveniles make use of riffle areas in summer and then
move into pools for the winter.
4.1.1.2 Arctic Grayling
Arctic grayling are most abundant in the Susitna River above the
·Chulitna River confluence, but they are also widely distributed below
196
the confluence. After spring breakup, adult Arctic grayling move into
the tributaries to spawn and then rear for the summer. Many juvenile
(less than 200 mm) Arctic grayling inhabit confluence areas of tribu-
taries and sloughs and also the mainstem during June through August.
Adult grayling migrate out of the tributaries in September and then
remain in the mainstem for the winter. Young of the year Arctic gray-
ling remain in the tributary headwaters until,September when some of
them move down to tributary mouths.
Distribution and Relative Abundance
Primarily due to the extensive use of boat mounted electrofishing units
in 1982, the catch of Arctic grayling below Devil Canyon ·increased from
498 in 1981 to 1,023 in 1982 (ADF&G 1981c, Table 3-3-2). In 1981,
Arctic grayling were captured as far downstream as RM 10.1, while in
1982, none were captured below RM 30.0. Sampling efforts in 1982,
however, was not as intensive as the 1981· effort below RM 60.0. In
general, Arctic grayling were found throughout the Susitna River basin
below Devil Canyon during· the ice free months. The distribution of
wintering fish . is yet unknown but a few catches have been made at
scattered locations.
The distribution of Arctic grayling at the 12 DFH sites sampled during
both 1981 and 1982 were similar. In 1982, Arctic grayling were captured
at 11 of the sites but in 1981 Arctic grayling were found only at eight
of the sites. This is explained, however, by the intensive use of
electrofishing equipment and beach seines in 1982 which were used to
197
capture fish at two of.the remaining sites. The only DFH sites sampled
both years where Arctic grayling were not captured was at Sunshine Creek
and Side Channel. Other ADF&G biologists have also failed to observe
Arctic grayling in that tributary system (Dave Watsjold, pers. cornm.).
Few seasonal comparisons can be made between 1981 and 1982 Arctic
grayling CPUE data due to inconsistent sampling efforts during the ice
free season. Gillnet and boat electrofishing CPUE's were high in June
and September and October in 1981, and in the same months of 1982.
A comparison of pooled CPUE rates for boat electrofishing at mainstem
and tributary or slough sites in 1982 reveals that CPUE's at tributary
or slough sites upstream of the Chulitna River confluence were consis-
tently higher than at rna i nstem sites above the confluence or at any
sites below the confluence (Figure 3-4-2). Although Arctic grayling
were most numerous at tributary mouths above the confluence, the high
CPUE' s at mainstem sites above the confluence in June indicate that
significant numbers of Arctic grayling utilize the mainstem at this
time. Since the high catch rate in the mainstem is recorded in spring,
it is probable that Arctic grayling use this reach of river in large
numbers to overwinter and then later migrate into tributaries or slo-
ughs. The use of the mainstem during winter is further substantiated by
observing the catch rates in late summer. As the seas.on progresses, the
catch rate at tributaries decreases and correspondingly increases at
mainstem sites.
For the reach of river below the Chulitna River confluence, the only
apparent seasonal trend is in June when higher catch rates were recorded
198
501
40
N •o
X
IJJ 30 ~
:::> z
::I!
a::
IIJ 20
a..
J:
0
~ < 0
9
8
C\J
•o 1
X
IJJ 6
~
:::> z 5
];
a:: 4
IJJ a.
l: 3 (.)
~ < (.) 2
0
CHULITNA RIVER ( R M 98.5) CONFLUENCE
TO DEVIL CANYON
D Tributary or Slough Sites
Ill Moinstem Sites
0 " ; ;;
0 0
0 0 z z
COOK INLET TO CHULITNA RIVER
(RM 98.5) CONFLUENCE
D Tributary or Slough Sites
Jl Moinstem Sites
I I I
0 0 0
I I I
1•15 16-31
JULY
" " ; a oc
Figure 3-4-2. Arctic grayling catch per unit of boat electrofishing
effort at tributary and mainstem sites on the Susitna
River between Cook Inlet and Devil Canyon, May to
September, 1982.
199
at all sites. The greater catches during the year above the confluence
in comparison to below the confluence was probably due to more prefer-
able habitat in that reach of the river.
The length percent frequencies of Arctic grayling captured by boat
electrofishing varies by season and by type of site (Figure 3-4-3).
Arctic grayling caught at mainstem sites were typically smaller in size
than those caught at tributary sites. In May, June, and September,
Arctic grayling over250 mm in fork length comprised a larger proportion
of the catch than in July and August. In July and August most of the
use of mainstem and tributary or slough sites is by 1\rctic grayling with
fork lengths less than 250 mm.
Adult Movement and Migration Patterns
A large percentage of the adult Arctic grayling population probably
migrated up tributaries immediately after ice out and prior to spring
sarnpl·ing. This appears to occur at least for the larger fish (fork
length over 300 mm) since very few large adults were captured during
spring and summer at mainstem or tributary mouth sites (Figure 3-4-3).
Morrow (1980) states this movement is composed of the largest fish which
exhibits a social heirarchy and territorialism upon residence. Similar
Arctic grayling behavior was observed in 1982 at most of the tributary
sites in the proposed impoundment with the smaller adults being sup-
planted to less preferable habitat at the foot of pools or at tributary
mouths (Volume 5).
200
Figure 3-4-3. Length percent frequencies of Arctic grayling captured by boat electrofishing
at tributary or slough and mainstem sites in the Susitna River below Devil
Canyon, May through September, 1982.
Recapture data indicate that Arctic grayling tend to restrict movements
except during a spring spawning run and a fall outmigration from tribu-
taries. Only 15 of the 48 fish recaptured in 1982 had moved from their
tagging location since the time of· tagging. Of these 15 fish, seven
moved during the spawning period in May and June. The maximum movement
evidenced by an Arctic grayling was during this time, when an Arctic
grayling was recaptured in late June 13.'3 miles upstream from where it
was tagged.
During the summer, most of the recaptured Arctic grayling were caught at
the same location where tagged indicating a sedentary behavior during
this time period. Most of the fish recaptured between July and mid
September were caught at the mouths of clear water tributaries upstream
of Talkeetna. Since most Arctic grayling were captured in backwater
pools or mixing zones at the mouths of the tributaries, it is probable
that these fish were at their permanent summer residence.
The outmigration of adult Arctic grayling from the tributaries to the
mainstem Susitna R~ver begins to occur in mid-September. Between
mid-September and mid-October electrofishing CPUE•s for Arctic grayling
progressively increased during 1981 and 1982 in the mainstem Susitna
River. Catch per unit effort was also relatively high in comparison to
summer months at the mouths of various tributaries during this time
indicating that Arctic grayling were outmigrating to overwinter in the
mainstem Susitna.
Although a fall outmigration is evident, there is little knowledge of
where the fish overwinter in the Susitna River. The fish probably
202
overwinter in schools near the mouths of their natal tributaries,
however, two fish :agged in May, 1981 and subsequently recaptured later
in 1981 moved 9.9 and 32.5 miles upstream (ADF&G 1981c). This movement
indicates that Arctic grayling may overwinter in the Susitna River at
various distances below their natal tributary.
Spawning
Catch data on juvenile and adult Arctic grayling and observation of
spent adults indicate that Arctic grayling probably spawn in tributaries
of the Susitna River prior to June.
Juvenile Rearing Areas
Juvenile (fork length under 200 mm) Arctic grayling were found rearing
at both tributary and mainstem sites during the summer of 1982. Most of
the juveniles were captured by boat electrofishing units at sites above
the Chulitna River confluence such as Lane Creek and Slough 8, Skull
Creek (RM 124.7), Indian River, Slough 20, Slough 22 (RM 144.2), and
Jack Long Creek (RM 144.5). Juveniles were ubiquitous in the mainstem
above the confluence, while below the confluence high catches were
recorded only at Goose Creek 1 (RM 72.0) and Goose Creek 2 and Side
Channel.
Juvenile Arctic grayling of ages 1+ and 2+ predominantly rear at the
mouths of tributaries between May and August, and then appear to move
into the mainstem during August. Although 1 ittle data on juvenile
203
Arctic grayling has been collected in the winter, juveniles probably
stay in the mainstem after August and remain through the winter.
The high catches of juvenile Arctic grayling at tributary mouths and at
mainstem sites probably occur because the smaller fish are displaced by
the larger fish to less preferable habitat (Morrow 1980).
Very few young of the year Arctic grayling were captured during 1982.
These fish probably resided for the summer in the upper reaches of the
tributaries near where they emerged. A large number of young of the
year Arctic grayling moved into Whiskers Creek and Slough during Septem-
ber 1982. Si nee the downstream migrant trap captured very few Arctic
grayling, these fish probably moved down from the upper reaches of
Whiskers Creek instead of moving in from the mainstem. In 1981, young
of the year Arctic grayling apparently moved down from the upper reaches
of Cache Creek (RM 96.0) in late September. Grayling probably rear near
these confluence . zones unt i 1 they are 1 a rge enough to compete for
territories in the desirable habitat upstream in the clearwater tribu-
taries.
4.1.1.3 Burbot
Burbot are widely distributed throughout the mainstem Susitna River
below Devil Canyon. Adults were found at tributary and slough mouths and
they are also abundant at mainstem areas. Burbot are typically seden-
tary but may move long distances during a spawning migration in the fall
and winter. The exact timing and locations of burbot spawning on the
204
Sus i tna River have not been documented, however 1 oca 1 residents report
that they spawn between November and February in tributaries and sl-
oughs. Juvenile burbot were captured at tributary mouths, clear water
sloughs, and at mainstem sites.
Distribution and Relative Abundance
Burbot distribution in 1982 was very similar to that found in 1981. All
12 DFH sites sampled in 1981 were found to have burbot present in both
years and those sites having large burbot ·catches in 1981 had large
catches in 1982. (ADF&G 1981c}~ Catches of burbot were generally
highest at mainstem sites in 1981; little comparative data is available
for 1982 sampling. Burbot abundance is probably greatest in mainstem
areas but burbot were captured in 1981 about three miles up Alexander
Creek (RM 10.1) and the Deshka River (RM 40.6). Burbot catches are
typically smaller at tributary mouths above the confluence. The five
DFH sites located between RM 131.0 and RM 140.1 recorded the lowest
catches of all DFH sites. Apparently, this reach of river is less
suitable for burbot than most other reaches of the river.
Adult Movement and Migration Patterns
Observations of the tagged burbot and a 1 so catch per unit effort data
indicate that for the most part burbot are relatively sedentary, how-
ever, during spawning time a definite movement can take place. (Morrow,
1980) This movement is thought to begin in September for burbot in the
Susitna River. Catch rates and percent incidence of burbot captured
205
during 1981 and 1982 generally increased during the summer and reached
their highest levels during September {ADF&G, 198lc; Appendix Table
3-A-23).
One radio tagged burbot and one recaptured disc dangler tagged burbot
moved 60.3 miles and 70.9 miles respectively during or just prior to the
indicated period of burbot spawning; spawning in the lower Susitna River
occurs between November and February. The radio tagged fish moved
downstream from RM 76.3 to RM 16.0 between October and February while
the other fish was recaptured in the mainstem at RM 79.0 in mid-Septem-
ber, it was tagged one year earlier at Alexander Creek {RM 10.1) two
miles upstream from its mouth (Appendix Tables 3-A-3 and 3-A-27).
Three other burbot were recaptured in the vicinity of their release
during 1982. Although one of the burbot was recaptured only five days
1 ater, the other two burbot were recaptured 45 and 69 days after they
were tagged. During this time these fish moved only 0. 0 and 1. 6 miles
indicating a sedentary behavior.
Spawning
Although no burbot were observed spawning in the Susitna River between
Cook Inlet and Devil Canyon during 1981 or 1982, examinations of sexua 1
development in necropsied burbot and information Qathered from personal
interviews of local residents indicate the burbot spawn between November
and February in tributaries and sloughs of the Susitna River.
207
Burbot necropsied in September and October had larger and more developed
gonads than those PXamined in June, but they were not fully ripe (Appen-
dix Table 3-A-28). By February, all mature burbot that were examined
had spawned. Residents 1 iving near Alexander Creek (RM 10.1) and the
Deshka River (RM 40.6) believe that burbot spawn enmasse at the mouths
of these two tributaries between November and February.
Observation of enlarged gonads in necropsied burbot captured on the
Susitna River during the 1981 and 1982 field seasons, indicates that
both male and female burbot are sexually mature at ages III or IV
(Appendix Table 3-A-28). The minimum length of sexually mature burbot
captured was 310 mm for males and 330 mm for females. Scott and Cross-
man (1973) also report that sexual maturity in burbot is attained at
ages II I and IV (280-480mm tota 1 1 ength) and that rna les can mature at
smaller lengths than females. Several unripe burbot over 300 mm in
length were found in the fall indicating that burbot may be nonconsecu-
tive spawners in the Susitna River.
Juvenile Rearing Areas
Juvenile burbot have previously been found to be most numerous at sites
below the Chulitna River confluence (ADF&G l98lc). They have been found
at both mainstem locations and up to three miles above the mouths of
tributaries such as Alexander Creek (RM 10.1) and the Deshka River (RM
40.6). Juvenile burbot in these tributaries are probably rearing near
the area of hatch. Young of the year burbot were captured at Slough 9
(RM 129.2) and this suggests that some burbot spawn at sites well above
208
the Chulitna River confluence. Other burbot juveniles were captured at
scattered DFH sites above the confluence. The downstream migrant trap
catch of burbot peaked in late June and late July. Burbot catches were
minimal during normal downstream migrant trap operation when the trap
was positioned at least six inches off the bottom. When the trap was
fished on the bottom, however, the burbot catch increased, indicating
the juveniles are closely associated with the bottom.
4.1.1.4 Round Whitefish
Round whitefish are most abundant in the Susitna River above the Chu-
litna River confluence and the numbers of them gradually decrease
downstream from the confluence. Adult round whitefish move into clear-
water tributaries in June to rear for the summer. Large numbers of
juvenile (Fork length less than 200 mm) round whitefish rear at tribu-
tary or slough mouths and in the mainstem Susitna above the Chulitna
River confluence during the summer. Young of the year emerge in June
and are found in largest numbers at slough and tributary mouths above
the confluence. In August and September, adult round whitefish drop out
of the tributaries and gather for spawning. Spawning may occur in the
tributaries or in the mainstem in October.
Distribution and Relative Abundance
Round whitefish were captured between RM 19.0 and RM 150.1 during 1982
and a similar distribution was evident during 1981 (ADF&G, 198lc).
209
A comparison of pooled CPUE rates for boat electrofishing at mainstem
and tributary site•: revealed that CPUE's at tributary or slough sites
upstream of the Chulitna River confluence were much higher than at
mainstem sites above the Chulitna River confluence or at all sites below
the confluence in 1982 (Figure 3-4-4). During June, however, catches in
the mainstem above the confluence were also high. The greater catches
during the year above the confluence were probably due to more prefer-
able habitat than that offered below the conflUence.
The length percent frequencies of round whitefish captured by electro-
fishing were similar by season and by type of site where captured
(Figure 3-4-5). Most of the catch was comprised of ftsh 200-300 mm in
fork length. Young of the year round whitefish were very infrequently
captured as electrofishing is biased toward the capture of larger fish.
A few seasonal differences ·in electrofishing catches are most notice-
able. At mainstem sites, most of the round whitefish captured during
May through August were less than 300 mm in fork length, but a higher
proportion of fish greater than 350 mm length were captured in Septem-
ber. At tributary or slough sites, fish over 300 mm fork length were
most often found in September while. juveniles under 150 mm were not
frequently sampled at this time. In September, large adults have
apparently moved out of tributaries and are getting ready to spawn.
Juveniles are perhaps displaced at this time from favorable habitat at
tributary mouths by the adults present.
The distribution of round whitefish captured at 12 DFH sites sampled
during both 1981 and 1982 were similar. In 1982 round whitefish were
210
80
70
N
'o 60
-
X
w !50
I-
:::> z 40
~
Cl::
w
Cl..
:X: " !! (.) ;; " I-0 0
"" I
(.)
0
20
18
16
C\J
I
0
X I
w
I-
:::>
~
~
Cl:: w
Cl..
J:
(.)
1-
<( !! (.) " 0
0 z
" 0
0
0 z
CHULITNA RIVER ( RM 98.5) CONFLUENCE
TO DEVIL CANYON
0 Tributary or Slough Sires
II Moinslem Site~
COOK INLET TO CHULITNA RIVER
(RM 98.5) CONFLUENCE
D Tributary or Slough Sites
• Main stem Sites
0 Cl 88
0 0 z z
JULY AUGUST SEPTEMBER
Figure 3-4-4. Round whitefish catch per unit of boat electrofishing
effort at tributary and mainstem sites on the Susitna
River between Cook Inlet and Devil Canyon, May to
September, 1982.
211
N ,_.
N
Tributary or Slough Sites Moinstem Sites
:s May-June
n:348
30
20
10
>->-
{.) {.)
2 2 30 July-Data Pooled With August UJ UJ
::I ::I
0 0 20
uJ UJ
0:: a: u.. 10 u..
.... 30 August .... 30 July-August z 2
UJ n=l43 UJ n=80 {.) 20 {.) 20 0:: 0:: ILl UJ a. a. 10 10
30 September 30 September
n= 156 n=IOS
20 20
10
0
101 151 201 2!51 301 351 450 101 151 201 251 301 351 450
FORK LENGTH (mm) FORK LENGTH (mm)
Figure 3-4-5. Length percent frequencies of round whitefish captured by boat electrofishing
at. tributary or slough and mainstem sites in the Susitna River below Devil
Canyon, May through September, 1982.
captured at all 12 sites but in 1981 catches were made at only nine of
the sites. This is explained, however, by the extensive use of boat
mounted electrofishing units in 1982 which caught fish at the other
three sites. This method proved to be most effective for capturing
round whitefish in the Susitna River.
Due to the effectiveness of the boat mounted electrofishing units the
round whitefish catch in 1982 was much greater than in 1981. The catch
also increased in 1982 due to the addition of a downstream migrant trap
(RM 103.0) which captured 95 more round whitefish in 1982 than all gear
combined did in 1981. Although round whitefish have been captured in
the summer between RM 19.0 and RM 150.1, the distribution of wintering
fish in the Susitna River is unknown.
Adult Movement and Migration Patterns
Seasonal CPUE•s at tributary sites above the confluence were highest
during late June, late August and late September (Figure 3-4~4). During
June and September the high catches were probably due to the in and out
migration of fish to and from the tributaries. The high catches in late
August may also have been due to movements out of the tributaries.
Although catches were low at all mainstem sites and at tributaries below
the confluence, catches progressively increased during the summer at
these sites. This was also probably due to the outmigration from the
streams. Length percent frequencies of electrofishing catches by month
also indicate a movement of adult round whitefish out of tributaries in
September (Figure 3-4-5). Although el ectrofishi ng was minima 1 during
213
1981 and a comparison of CPUE's for 1981 and 1982 is not possible,
gillnet CPUE's in 1981 also indicate similar seasonal trends (ADF&G,
1981c).
Although several of the 36 round whitefish that have been recaptured
thus far moved during the summer, most of the fish that moved were
recaptured during the fall. This fall movement, in September, was
probably due to a spawning migration. In other systems, this migration
is annual and can be an upstream movement (Morrow 1980). Observations
of tag recoveries also indicates that an upstream migration can occur in
the Susitna River as five (29.4%) of 17 fish recaptured in September
moved upstream from where they were tagged. Apparently the fish move
relatively long distances to spawn as six moved over ten miles, either
upstream or aownstream during September. Only one other fish moved over
ten miles and that was during late May. Although the only major season-
al movement is evident during fall, a spring migration from an over-
wintering area may be undertaken by some fish as· one fish moved 32.6
miles between October 2, 1981 and May 22, 1982.
Spawning
The spawning of round whitefish in the Susitna River between Cook Inlet
and Devi 1 Canyon occurs after early October. Sexually mature round
whitefish were captured in pairs and small groups in the mainstem
Susitna River during early October at RM 100.8 in 1981 and at RM 102.6
in 1982. Similar observations of paired round whitefish were first
noted in mid-September. The round whitefish may spawn in the mainstem
214
but large schools of round whitefish were also gathered at the mouth of
Portage Creek in late September. These fish might have been grouping for
a spawning run up the creek or they may spawn at the creek mouth.
Juvenile Rearing Areas
Juvenile (fork length under 200 mm) round whitefish were found rearing
mostly in clear water sloughs in the reach of river between the Chulitna
River confluence and Devil Canyon. Although most of the juveniles
captured by mobile gea~were found in slo~ghs such as Slough 6A, Slough
BA, Slough 9, and Slough 21, juveniles were also captured at mouths of
several tributaries above the confluence such as Gash Creek (RM 111.5)
and Fourth of July Creek. The only site below the confluence where
relatively large catches were made was at Goose Creek 2 and Side Chan-
nel.
Most of the juveni 1 e round whitefish, however, were captured by a
downstream migrant trap at RM 103.0. An early July movement of young of
the year round whitefish was evident from trap catches (Table 3-3-4).
The area where these fish were moving to, however, is not known. Low
catches were recorded at all sites below the confluence except for Goose
Creek 2 and Side Channel.
The majority of young of the year round whitefish, however, probably
rear in the vicinity where hatched. The first observations of young of
the year (fork length 23 mm) were recorded at Rabideux Creek and Slough
215
and Slough 9 in late June. Although this was the only occurrence of
young of the year· at Rabideux, young of the year were consistently
captured after June at Slough 9.
4.1.1.5 Humpback Whitefish
Humpback whitefish were distributed throughout the mainstem Susitna
River below Devil Canyon but are more abundant below the Chulitna River
confluence. Adult humpback whitefish (fork length over 200mm) are often
found at tributary or slough mouths. They are not commonly captured in
the mainstem except during their spawning run. Their spawning run
begins in early August and runs well into September. Major rearing
areas for juvenile (fork .length under 200mm) humpback whitefish are
believed to be located below the Chulitna River confluence but their
exact locations are unknown.
Distribution and Relative Abundance
Humpback whitefish are widely distributed throughout the Susitna River
system. but they were caught in relatively small numbers during 1982. A
comparison of pooled CPUE rates for boat electrofishing at mainstem and
tributary sites, (Figure 3-4-6) revealed that CPUE 1 s at tributary or
slough sites.were much higher than in the mainstem. Seasonal CPUE•s at
mainstem sites sampled were higher in June, late August. and September
than in July. These trends are apparent both above and below the
confluence of the Chulitna River.
216
B
7
N
I
0 6
X
LLI 5 1-
~ z
~ 4
a:
LLI 3
Q_
:X: 2. 0
1-
<{
0
0
14
N 'o 12.
X
LLI 10
1-
~ z B
::::t
a:
LLI
Q_ 6
:X:
0 4
1-
<{
0 2.
0
I
0
I
CHULITNA RIVER (RM98.5) CONFLUENCE
TO DEVIL CANYON
!
0
0
0 z
0 Tributary or Slough
Ill Moinstem Sites
1-H~ 16 • 31
JULY
COOK INLET TO CHULITNA RIVER
(RM96.5) CONFLUENCE
D Tri butory or Slough
• Moinstem Sites
a "' ; g
JJ 0 0
" 0 z z
l£l I
1"15 1s-31 I I • 15 16-30
AUGUST SEPTEMBER
Figure 3-4-6. Humpback whitefish catch per unit of boat electrofishing
effort at tributary and mainstem siteson the Susitna River
between Cook Inlet and Devil Canyon, May to September,
1982. .
217
The distribution and abundance of humpback whitefish in 1982 was very
similar to that ft~und in 1981 (ADF&G 1981c). At the 12 DFH sites
sampled during both 1981 and 1982, humpback whitefish were captured at
eight of the sites in both years, while at 4th of July Creek and Slough
20 no humpback whitefish catches were recorded in either year. Rela-
tively large catches of humpback whitefish were made at Portage Creek
and Sunshine Creek during both field seasons. More humpback whitefish
were captured in 1982 due to the increased use of boat electroshockers
which are more effective than other gear in capturing humpback whitefish
in the Susitna River. Catches at the Sunshine fishwheels during mid-
August to mid-September in both years were comparable, with 123 captured
in 1981 and 103 captured in 1982.
Examination of necropsied humpback whitefish indicates that the species
of humpback whitefish complex found in the Susitna River is Coregonus
pidschian. A modal gill raker count of 22 was the same as reported by
Morrow (1980) for h pidschian (Appendix Table 3•A-35). The Alaska
whitefish l_h nelson;) and lake whitefish Jl. clupeaformis) have modal
counts of 24 or more. These data indicate a range extension of h
pidschian to that presented by Morrow (1980) who reported this species
to be restricted to northern and western Alaska. It is possible that
two fish examined with gill raker counts of 26 are individuals of one of
the other two species, as Morrow (1980) reports maximum gill raker
counts of 25 for h pidschian. McPhail and Lindsey (1970), however,
discuss the uses and 1 imitations of gi 11 ra·ker counts and recommend
characterizing a sample with a single mode as that of a single species.
218
Morrow (1980) refers to tbe humpback whitefish (h pi dschi an) as an
anadromous fish, but he also indicates that some humpback whitefish may
not venture into estuary zones at all. In the Susitna River, 116
humpback whitefish were aged by scale analysis; of these, only one fish
was found to have spent part of its life in the estuary or ocean. In
the Susitna, the majority of humpback whitefish may spend most of their
time, at least during the summer, in the river system. Adult humpback
whitefish were found scattered throughout the mainstem Susitna or at
tributary mouths below Devil Canyon during the months from May to
October. The distribution of wintering fish in the Susitna is unknown.
Adult Movement and Migration Patterns
Morrow (1980) reports that the spawning run of humpback whitefish begins
in June and runs throughout September. The fish spawn in the period
from October to mid November. Apparently, most populations winter in an
estuary environment.
In the Susitna, fishwheel catches indicate that there is a movement of
fish from the lower river to upper reaches of the river in August and
September (Appendix Table 3-A-40). Catches peaked at Yentna (RM 27.5,
TRM 6.0) in early and l.ate August, at Sunshine (RM 79.0) in late August,
and at Ta"lkeetna (RM 103.0) 120.0) in early September. Presumably these
fish were moving upstream to their spawning areas.
Tagging efforts thus far have revea 1 ed 1 ittl e about the movements of
adult humpbacked·· whitefish due to the sma 11 number of tag recoveries.
219
Four fish tagged in early to mid September, 1981 at the Sunshine fish-
wheels were recovered in 1982 (Appendix Table 3-A~41). Three of these
fish were recovered in May and July from 16 to 38 miles downstream while
the other fish was again recovered at the Sunshine fishwheels in Septem-
ber. It is likely that the three fish recaptured during May to July
were initially captured during their spawning run and subsequently
recovered at their summer habitat.
The humpback whitefish apparently moves all summer in the mainstem in
small numbers but the spawning run is the major movement. Three of the
four recoveries of humpback whitefish tagged in summer of 1982 reveal
little movement. One fish, however, tagged on August 11 at the Yentna
fishwheels was recovered 6 days later in the mainstem at RM 19.0, a
downstream movement of 14.5 miles.
Spawning
Observations of gonadal development of necropsied humpback whitefish
captured in the Susitna River during 1982 indicate that humpback white-
fish spawn after early October in the Susitna River basin. Dbservations
made during 1981 also indicated a similar timing of spawning (ADF&G
1981c).
Observation of catch data collected from fishwh~els on the Susitna River
at Yentna River (RM 27.5, TRM 6.0), Sunshine (RM 79.0), and Talkeetna
(RM 103.0) indicates an upriver spawning migration of humpback whitefish
beginning in mid August. The peak migration recorded at the fishwheels
220
occurred first at Yentna River between August 8 and Auguit 31, and then
at Sunshine Station between August 16 and September 7. Catches at the
Talkeetna and Curry fishwheels during· September were small indicating
that humpback whitefish spawn primarily below Talkeetna or else run up
other tributaries such as the Talkeetna or Chulitna River.
No spawning or spent humpback whitefish were captured in the rna i nstem
Susitna River. Humpback whitefish probably spawn in various tributaries
rather than in the mainstem.
Observance of ripening eggs in all necropsied adult females over 300 mm
fork length indicates that humpback.whitefish are consecutive spawners
in the Susitna River.
Juvenile Rearing Areas and Movements.
The downstream migrant trap operated at Talkeetna station (RM 103.0)
captured 47 young of the year humpback whitefish migrating downstream.
It is not known where the fry came from or where they rear. Most of the
humpback fry were captured in August but one was captured on July 8.
Other gear types were not effective in captur"ir1g juvenile humpback
whitefish. No humpback whitefish juveniles (fork length under 200mm)
have been captured above Whiskers Creek and Slough in the two years of
study except at the downstream migrant trap located at Talkeetna station
In 1981, juvenile humpback, whitefish were captured with minnow traps at
Alexander Creek (RM 10.1), Kroto Slough (RM 30.1), Deshka River (RM
221
40.6) and Whiskers Creek and Slough. In 1982, juvenile humpback white-
fish were caught at Goose Creek 2 and Side Channel and at Sunshine Creek
and Side Channel. Boat electrofishing gear wa,s used to capture juve-
niles at Whitsel Lake Slough (RM 35.2), an unnamed tributary to Kroto
Slough at RM 38.5, Sunshin~ Creek and Side Channel, below a beaver dam
at RM 86.3, Trapper Creek (RM 91.5), and three mainstem sites below the
Chulitna confluence. Apparently the juveniles rear in areas below the
Chulitna confluence but the gear types deployed in the areas sampled
have failed to reveal any large concentrations of rearing juveniles.
4.1.1.6 Longnose Sucker
Longnose suckers are an abundant resident species found throughout the
Susitna River below Devil Canyon. Spawning occurs between late May and
early June. During this time large concentrations and movements of
longnose suckers may occur. During the rest of the year, longnose
suckers appear to be more dispersed. Populations are highest near
mouths of tributaries but juveniles and adults also make use of the
mainstem during the ice free months. The winter distribution of
longnose suckers is unknown as are the major rearing areas of juveniles.
Distribution and Relative Abundance
Longnose suckers occurred at all the DFH sites sampled in 1982 and were
captured in large numbers at many of these sites. They were captured in
small numbers at only 9 of the 12 DFH sites sampled in 1981. The more
222
widespread di stri buti on and greater abundance of 1 ongnose suckers at
these DFH sites in 1982 is mostly due to the greatly increased use of
electrofishing units and beach seines in 1982, rather than actual
changes in abunaance.
Since boat electrofishing gear was most effective for capturing longnose
suckers, relative abundance is best studied by examining CPUE's at
different sites sampled by this method (Figure 3-4-7). Boat electro-
fishing CPUE's for longnos·e suckers were typically higher at tributary
or slough sites than at. mainstem sites. At mainstem sites above the
Chulitna River confluence, boat electrofishing CPUE's were typically
higher than at mainstem sites below the confluence. No large seasonal
trends are apparent, although CPUE•s at tributary or slough sites above
the confluence appear to be higher in August and September than in June
and July. Possibly longnose suckers move into these tributary or slough
sites to feed on salmon eggs.
Longnose sucker adults were found in number at both mainstem and tribu-
tary sampl·ing sites. They are one of the few resident species which
make use of the mainstem ·in number over the entire ice free season. In
winter, little is known of the distribution of longnose suckers in the
Susitna as very few have been captured anywhere. Schools of longnose
suckers were encountered in the mainstem in early September but normally
only scattered individuals were captured during the rest of the season.
At tributary mouths, longnose suckers were often encountered in schools
or in groups along a limited area of the site electrofished.
223
44
40
36
32
C\1
I
0 28
X
w 24 .....
::::)
z zo
:I!
a:: I 6 w a..
::1:: I 2 0 .....
<[
0 8
4
0
c 0
~ ~
CHULITNA RIVER (RM 98.5) CONFLUENCE
TO DEVIL CANYON
0 Tributary or Slough Sites
• Mainstem Sites
COOK INL'ET TO CHULITNA RIVER
( RM 98.5) CONFLUENCE
0 Tributary or Slough Sites
• Moinstem Sites
a a a ; o a
0 0 z z
Figure 3-4-7. Longnose sucker catch per unit of boat electrofishing
effort at tributary and mainstem sites on the Susitna
River between Cook Inlet and Devil Canyon, May to
September, 1982.
224
Adult Movement and Migration Patterns
None of 21 longnose suckers adults that had been tagged and recaptured
moved over 8 miles and 14 of these fish were recovered at the same
location where they were originally tagged (Appendix Table 3-A-47, ADF&G
l981c). Six of the fish which did move were recovered after August 1
indicating a possible pattern of movement beginning at this time. Catch
rates at mainstem and tributary sites with boat electrofishing units
increased after August 15, indicating that a movement was occurring into
some areas and through others (Figure 3-4-7). Possibly the fish are
moving toward the wintering grounds from clear water tributaries.
Schools of longnose suckers were encountered below RM 50.0 in the
mainstem in early September although very few longnose suckers had been
encountered in August in the same area.
In the spring, catch data indicates that longnose suckers congregated at
the mouths of the tributaries to spawn. The size of the spawning
migration or movement is not known. Fishwheel catches at the three
Susitna fishwheel sites were higher in June than in July indicating more
movement in the mainstem early in the season. Mainstem catches were
much lower than tributary catches during late May and early June at SFH
sites.
Spawning
Longnose sucker spawning in the mainstem Susitna River was evidenced at
two locations during late May ancj early June, 1982. Sexually mature and
225
spent 1 ongnose suckers were captured at the mouth of Trapper Creek ( RM
91.5) and at Sunshine Creek and Side Channel (Appendix Table 3-A-48).
Catch per unit effort data indicate peak spawning occurred before June
lOth at both sites (Appendix Tables 3-A-43 and 3-A-45).
Although relatively large concentrations of adult. longnose suckers were
captured at both locations, few adults were captured that were sexually
mature or spent, indicating longnose suckers in the Susitna River
drainage may be nonconsecutive spawners. Geen et al. (1966) reported
that some longnose suckers spawn two of three consecutive years while
others miss one or two years between spawnings.
Captured ripe male and female longnose suckers were a· minimum five
years of age (Appendix Table 3-A-48). McPhail . and Lindsey (1970)
reported that in central British Columbia males first spawned at age V
while females first spawned at Age VI or VII.
Although no fall spawning of longnose suckers ha·s been documented (Scott
and Crossman 1973, Morrow 1980), observations of ripe males captured in
September indicate spawning may also occur during late fall in the
Susitna River (Appendix Table 3-A-48).
Juvenile Rearing Areas
Juvenile (fork length under 200 mm) 1 ongnose suckers were found rearing
at a variety of sloughs and a few tributary mouths below Devil Canyon
during summer 1982. They were often found in sloughs above the Chulitna
226
River confluence such as Slough 6A, Slough BA, Slough 9, and Slough 22.
The mouths of 1 arge tributaries such as Lane Creek and Slough 8, Fourth
of July Creek, and Portage Creek were often used by adult longnose
suckers but juveniles ~ere only rarely found there. Below the Chulitna
River confluence, a similar trend was apparent, many adult longnose
suckers were captured at the mouths of RabidetJX Creek and Slough and
Sunshine Creek and Side Channel but few juvenile longnose suckers were
found at those sites. Goose Creek 2 and Side Channel was an exception
as both adults and juveniles were abundant there.
Morrow (1980) reports a downstream movement of longnose fry after
emergence in some streams but this movement does not appear extensive in
the Susitna River below Devil Canyon. The downstream migrant trap
captured very few longnose suckers (Table 3-3-6) and very few of these
were young of the year.
4.1.1.7 Oqlly Varden
Adult Dolly Varden make use of the mainstem Susitna River from September
through June, however no specific wintering areas for Dolly Varden have
.,
been documented. During July and August adults were found at tributary
mouths, but most of the population is believed to reside in clear water
tributaries well above their confluences with the Susitna. Populations
of dwarf sized Dolly Varden may also inhabit the upper reaches of clear
water tributaries above Talkeetna. Juvenile Dolly Varden are thought to
be similarly distributed. There is no evidence to suggest that these
juveniles overwinter in the mainstem Susitna. Anadromous Dolly Varden
227
may also occur in the Susitna drainage but the majority of fish appear
to be resident to the system. Dolly Varden are thought to spawn in
clear water tributaries in October.
Distribution and Relative Abundance
Dolly Varden were sampled in relatively small numbers in comparison to
other species of resident salmonids (rainbow trout, round and humpback
whitefish, and grayling). A comparison of boat e1ectrofishing CPUE's
for tributary and mainstem sites above and below the confluence of the
Chulitna River shows few trends (Figure 3-4-8). Catch per unit efforts
at mainstem sites decreased in late June. Overall, the CPUE for main-
stem sites (0.20 fish/minute x 10-2 ) was much less than the CPUE for
tributary sites (1.18 fish/minute x 10-2 ). Catches at fishwheels in the
mainstem Susitna i.ndicated more use of the mainstem by Dolly Varden in
June and September than during other times in the summer (Appendix Table
3-A-53). Catches were too low to show any apparent differences between
mainstem use above and below the confluence.
The abundance and distribution of Dolly Varden ,was very similar in both
1981 and 1982. At the 12 DFH sites sampled in both 1981 and 1982, Dolly
Varden were found at seven sites in 1981 and eight sites in 1982. They
were present both years at Birch Creek and Slough, Lane Creek and Slough
8, 4th of July Creek, Indian River and Portage Creek. At Slough 11 and
Slough 21, Dolly Varden have not been present.
During 1981 and 1982 sampling in the upper reache~ of Portage Creek and
Indian River, many small Dolly Varden were captured (ADF&G 198lc;
228
3
C\1 CHULITNA RIVER (RM 98.5) CONFUENCE
'o TO DEVIL CANYON -
X 0 LJJ 2 Tributary or Slough Sites
.....
=> Ill Mairostem Sites ~
:E
a::
LJJ 0 a.
:X: ~
I I I u 0 0 0 0 ..... z
<( I I I
u 0
I •15 16•31
JULY
5
4 COOK INLET TO CHULITNA RIVER
(RM96.5) CONFLUENCE
C\1
'o 0 Tributary or Slough Sites
X
3 • Mainstem LJJ Sites ..... => z
~
a:: 2 LJJ a..
:X:
u
I-
:Ull
<( u I
2 ~ 0 0
0 0 0 ;;
0 0 0 0
I I
0 0 0 0 () 0
I z z I z z
0 I -~-· ,~
16·30 r I ·15 16•30 I· 1!1
JUNE JULY SEPTEMBER
Figure 3-4-8. Dolly Varden catch per unit of boat electrofishing effort
at tributary and mainstem sites on the Susitna River
between Cook inlet and Devil Canyon, May to September,
1982.
229
Appendix Report 3·D-1). Dolly Varden in these areas are probably
separate populatiors of stunted fish. Morrow (1980) reports this occurs
in the upper reaches of many streams and mountain lakes. Stunted Dolly
Varden were also collected in studies above Devil Canyon (Volume 5). At
the sites sampled in upper Portage Creek and upper Indian River, 1981
minnow trap CPUE • s were much greater than 1982 CPUE • s. In 1981, Dolly
Varden catch per trap unit was 0.46 in Indian River and 1.06 in Portage
Creek while in 1982 catch per trap unit dropped to 0.03 in Indian River
and 0.18 in Portage Creek. The causes of this yearly variation are
unknown. The sampling effort was not constant over the season in 1981
and 1982 and this may have accounted for some of the difference. Also
trap sets in 1981 were approximately 24 hours in length while sets made
in 1982 were only three hours in length. It is possible that Dolly
Varden feed primarily at twilight or during the night and therefore
would not be caught in comparable numbers in three hour sets made during
the middle of the day.
Morrow (1980) reported Dolly Varden to generally be found in the upper
reaches of stream drainages. The limited catches of Dolly Varden in the
Susitna drainage thus far indicate that this is the case in the Susitna
drainage below Devil Canyon.
Adult Movement and Migration Patterns
In late June, boat electrofishing CPUE's (Figure 3-4-8) and fishwheel
catches dropped indicating a movement of fish from the m.ainstem into
tributaries. Catches indicate a few fish move about in the mainstem and
?.30
just off tributary mouths all summer but the main populations are
assumed to be in t~e upper reaches of tributaries. Clear water sloughs
such as Slough 11 and Slough 21 do not appear to harbor fish over the
summer. The few recoveries of tagged Dolly Varden made thus far indi ...
cate generally long migrations by Dolly Varden may occur in the Susitna
River (Appendix Table 3-A-60). A Dolly Varden tagged on May 25 in the
mainstem near Montana Creek (RM 77 .0) was captured by a sport fisherman
at Fish Creek, a tributary about six nver miles up the Talkeetna River
(RM 97.0), sometime later in the spring or summer, an upstream movement
of 25 river miles. This fish probably spent the winter in the Susitna
mainstem and then was moving to summer habi-tat when captured by the
fisherman. Two other Dolly Varden tagged in June at the mouth of Lane
Creek were captured in the mainstem in late August at the Curry fish-
wheel site (RM 120.0). These fish may have been moving upstream to
spawn as Dolly Varden are fall spawners (Morrow, 1980).
Spawning
Spawning of Dolly Varden can occur between late August and November
according to Morrow (1980). Adult Dolly Varden necropsied during
September and October, 1981 evidenced enlarged gonads but were not yet
sexually mature, indicating that they spawn after mid-October in the
lower Susitna River.
During six sampling trips to upper Portage Creek and upper Indian River
between May and August, no sexually mature "dwarf,. Dolly Varden were
captured.
231
Juvenile Rearing Areas and Movements
Little is known of juvenile Dolly Varden habits in the Susitna drainage
below Devil Canyon. In the summer months minnow trap sampling at the
mouths of many tributaries over the two years of study have only made
occasional catches of juvenile Dolly Varden. These results suggest that
juvenile Dolly Varden rear in tributaries well above the influence of
the mainstem Susitna. In the winter, juveniles may move downstream in
their tributaries but minnow trapping has not revealed the presence of
any appreciable numbers of Dolly Varden at stream mouths or in the
mainstem over the winter months.
4.1.1.8 Threespine Stickleback
Threespine stickleback are most abundant .in the Susitna River below the
Chulitna River confluence, and they are infrequently captured less
frequently above RM 120.0. Populations of threespine stickleback were
much 1 ower in 1982 than in 1981. An upstream movement of threes pine
stickleback may occur in late May and early June in the lower 40 miles
of the Susitna. Spawning occurs in June and July at tributary and
slough mouths and subsequently juveniles rear at these sites. Fall
movements and the distribution of threespine stickleback in the winter
have not been delineated.
Distribution and Relative Abundance
In 1982, the distribution of threespine stickleback was more restricted
and the catch was smaller than during the 1981 field season. At the 12
232
DFH sites sampled in both 1981 and 1982, threespine stickleback were
found at nine of t~e sites in 1981 and only four of the ~ites in 1982.
At Slough 6A, 773 stickleback were captured in early June, 1981 while
not a single fish was captured at this site during the entire 1982 field
season. At Sunshine Creek and Side Channel, Birch Creek and Slough, and
Whiskers Creek and Slough, threespine stickleback were present in both
years. At these three sites, average CPUE's of minnow traps for the
three sites were much greater in 1981 than in 1982. Seasonally, the
highest CPUE's were found in June and July in bothyears. No threespine
stickleback were found at Indian River or Portage Creek in either year.
Goose Creek 2 was the only DFH site sampled in both 1981 and 1982 where
threespine stickleback were not found in 1981. This site was not
sampled, however, until late July in 1981. In 1982, only two threespine
stickleback were captured in minnow traps at Goose Creek 2 after 1 ate
June. The reason for this va~t difference in yearly catches and CPUE's
between 1981 and 1982 is unknown. A possibility is that the high water
during the summer of 1981 flushed the fish downstream.
Threespine stickleback are potentially competitive with juvenile sockeye
salmon and rainbow trout for food (Morrow 1980). Areas of threespine
stickleback abundance however, such as Sunshine Creek and Side Channel,
Birch Creek and Slough, and Whiskers Creek and Slough have few juvenile
sockeye salmon or rainbow trout rearing in their confluence areas.
Opportunities for competition (at least in these areas of direct Susitna
River influence) are thus minimized, and threespine stickleback occur-
rence probably ha.s very 1 ittle effect on these salmonids.
233
Adult Movement and.Migration Patterns
The threespine stickleback has an anadromous form and a freshwater form
(Morrow 1980). The two forms are distinguished primarily by the number
of bony plates, five to nine per side on freshwater forms and 27 to 37
plates per side on anadromous forms. Unfortunately, counts of plates on
individual specimens captured during this study have not been made. It
is not known, therefore, which of the two forms inhabit the Susitna
drain age.
During late May and early June, 1982, up to 40 threespine stickleback
were captured in one dipnet sweep at several sites in the mainstem below
RM 40.0 (D. Lang and S. Krueger, ·pers. comm.). These fish were believed
to be moving upstream enmasse to spawning sites or summer feeding
grounds. They apparently had overwintered in the estuary or in deep
water near the mouth of the Susitna.
In 1981, the numbers of threespine stickleback caught were very high at
several sites sampled in June and then gradually decreased over the
summer (ADF&G, 1981c). During the 1982 season, there never were any
noticeable trends in numbers of threespine stickleback. The number of
threespine stickleback stayed consistently low all through the summer
sampling period.
Spawning
Threespine stickleback with total lengths as small as 50 mm were believ-
ed to have spawned in 1982. In 1981, only breeding male threespine
234
stickleback with lengths greater than 70rnm were observed ·in spawning
colors and they WP:"'e observed during the period from mid-June to early
August.
Observations of carcasses of spawned out threespine stickleback and high
catch rates of threespine stickleback. indicate peak spawning occurred
during early July in both 1981 and 1982. The period of peak spawning is
thought to occur earlier in areas near the mouth of the Susitna River
and then progress upriver.
Juvenile Rearing Areas
Young of the year threespine stickleback were found in late July and
early August in the same areas that adults occupied. Catches of three-
spine stickleback fry in a downstream migrant trap in the mainstem were
highest in late August and September suggesting a downstream movement of
threespine stickleback fry occurs at this time.
4.1.1.9 Slimy Sculpin
Slimy sculpin were widely distributed throughout the Susitna River below
Devil Canyon and occurred at nearly all sites studied. They are present
year round and .no large scale movements or migrations were evident.
Spawning, juvenile rearing and adult movements all -are confined to a
1 imited area. Populations are greatest at the mouths of clear water
tributaries but mainstem areas also harbor resident populations.
235
Distribution and Relative Abundance
Slimy sculpin were very widely distributed throughout the sites sampled
and were captured all year long~ At the 12 DFH sites. sampled in 1981
and "1982, slimy sculpin were captured at a11.12 sites during both years
(ADF&G 198lc; Appendix Table J"'A-66). In 1982, catches at DFH sites . .
above Slough 8A were generally much less than at sites below this
slough.
At a given DFH site, however, cottids usually were not caught in number
except after young of the year became readily catch~ble. Generally fish
were scattered throughout a site. Morrow (1980) reports slimy sculpin
to be generally abundant and 1 imited catches of this species are pro-
bably a function of gear selectivity.
Adult Movement and Migration Pattern
No evidence of major movements or migration was gathered. Morrow (1980)
also reports that slimy sculpins do not migrate (except for anadromous
populations) and are sedentary. They may disperse somewhat during the
breeding season as males set up territories in favorable breeding habi-
tat.
Spawning
Catches of young of the year slimy sculpin in late July suggest spawning
occurs about mid June. Morrow (1980) reports spawning occurs shortly
after breakup.
236
Juvenile Rearing Areas
Juveniles were found in largest numbers wherever adults were found in
large numbers. After hatching, they probably disperse into the area
surrounding where they were hatched. The downstream migrant trap failed
to pick up any young of the year slimy sculpin and this indicates there
is probably not a long distance movement from ar.eas of hatch.
4.1.1.10 Arctic Lamprey
Catches of Arctic lamprey were relatively low in 1982, but this is not
indicative of the actual abundance of the species in the Susitna River.
During 1981 studies (ADF&G 1981c), most of the tributary sites producing
Arctic lamprey were locat~d below RM 50.5 except for Goose Creek 1 (RM
72.0), Montana Creek (RM 77.0} and Whiskers Creek and Slough. Sampling
effort at tributary sites below RM 50.5 in 1982 was limited to boat
electrofishing at only a few sites. Arctic· lamprey were captured or
observed at most of these lower tributary sites electrofished and they
are believed to be abundant at tributary mouths below RM 50.5.
Arctic lamprey are much less numerous above the confluence but there are
localized concentrations at Whiskers Creek and Slough (RM 101.2) and
Gash Creek (RM 111.5). Spawning occurs at these sites as ammoceotes
were captured. Below the confluence, spawning was documented at Birch
Creek and Slough during late June and probably occurs at other tributary
mouths, especially those below RM 50.5.
237
Assuming 180 mm is the maximum length of the freshwater form of Arctic
lamprey (McPhail c:-..d Lindsey 1980, Morrow 1980), only two anadromous
Arctic lamprey were caught in 1982. In 1981 all Arctic lamprey greater
than 180 mm were captured between RM 10.1 and 40.6. The capture sites
(RM 88.4 and 103.0) of the two anadromous lamprey caught this year were
considerably further upstream than the upstream limit observed in 1981.
If these are indeed anadromous Arctic lampreys then a spawning run would
occur in the spring. Other movements . and migrations by freshwater
populations present have not been delineated.
4.1.2 Juvenile Anadromous Fish Species
4.1.2.1 Chinook Salmon
Chinook salmon juveniles were distributed throughout the sampling area
from Goose Creek to Slough 21 during the open water season of 1982. The
only OFH site where juvenile chinooks were not captured was· Portage
Creek mouth. Seasonally, the highest catches in the lower reach (below
the Chulitna River confluence) occurred in late June and July and the
highest catches in the upper reach (above the Chulitna River confluence)
were recorded in late June, late August, and early September.
Catches in the lower reach were generally higher than those observed in
the upper reach. Relatively large numbers of chinooks were captured at
four (Goose Creek 2 and Side Channel, Rabideux Creek and Slough, Sun-
shine Creek and Side Channel, and Birch Creek and Slough) of the five
238
sites surveyed in the lower reach. 'In the upper reach, the site where
the most chinook jtifeniles were caught was the most downstream DFH site
in that reach, Whiskers 1 S Creek and Slough.
The most noticeable difference between 1981 and 1982 catches of chinook
salmon juveniles was the decrease in distribution and relative abundance
of juvenile chi nooks in 1982 in the reach above the Chulitna River
confluence. The reason for this decrease is unknown but may be a result
of one or more of several factors: the high flows recorded during the
summer of 1981, severe condi.tions during 1981-1982 winter, or an un-
usually damaging ice-out in the spring of 1982.
Similarly, the catch of chinook salmon juveniles at the six SFH sites in
upper Indian River and upper Portage Creek showed a dramatic decrease in
1982 compared· to 1981 (see Appendix Report 3-D-1). Only one chinook
salmon juvenile was captured in upper Indian River in 1982, while none
were captured in upper Portage Creek (not sampled in August or Septem-
ber).
Although no chinook juveniles were captured in the upper reaches of
Portage Creek or at Portage Creek mouth in 1982, age 0+ chinook salmon
juveniles were captured at Slough 20 and Slough 21. The only presently
known chinook spawning areas upriver of these sloughs are Portage Creek
and two small creeks located in lower Devil Canyon. The chinook juve-
niles at Slough 20 may have originated in Portage Creek, but were not
captured during the twice monthly sampling conducted at the mouth.
239
The highest numbers of juvenile chinook salmon observed at DFH tributary
sites were collected in late June, early July, and during September in
both the 1981 and 1982 seasons. The di stri buti on and abundance of
juvenile chinook salmon observed in 1982 at DFH and SFH sites in the
Chulitna River to Goose Creek reach were similar to the distribution and
abundance observed at many of these sites in the 1981 season. Catch
rates at most sites in the Chulitna River to Goose Creek reach decreased
in September during 1981 and 1982. An increase in the number of age 0+
chinook juveniles was apparent at most DFH sites in the reach above the
Chulitna confluence during 1981 and 1982 as the open water season
progressed. This was most obvious at Whiskers Creek and Slough 21,
where catches increased during each two week i nterva 1 from June to
mid~September for age 0+ fish in 1982. Chinook juveniles collected from
Slough 8A in 1 ate August 1982 probably originated from Fourth of July
Creek, Indian River, and possibly Portage Creek. Maximum catches of
juvenile chinook salmon were collected at Fourth of July Creek mouth and
Indian River mouth in late August.
The low numbers of chinook salmon juveniles collected from February
through April, 1982, make it difficult to identify any patterns. In
general, chinook juveniles were captured throughout the reach sampled
and no seasonal trends were apparent. Relatively higher numbers of
chi nook juveni 1 es were captured at Slough 10 and Slough 20 in the
winter. A similar trend was evident during the 1980-1981 winter sampl-
ing. A movement by chinook salmon juveniles into these two sloughs in
September has been noted in both 1981 and 1982. This is a time of year
when juvenile salmon move out of tributaries. These two sloughs evi-
240
dently pro vi de important overwintering habitat for juveni 1 e chi nooks.
Whiskers Creek and Slough is another site where chinook juveniles were
relatively abundant during both winters. All three sites have fairly
deep pools of calm water.
Chi nook sa 1 mon juveni 1 es were abundant at Whiskers Creek and Slough
during the 1981 and 1982 open water season. However, they were 1 ess
abundant at Slough 10 and Slough 20 during the 1981 and 1982 open water
seasons, indicating that the use of these two sloughs is seasonal.
A seasonal separation by age class was apparent at several sites. A
peak abundance of age 1 + fish occurred prior to the peak abundance of
age 0+ fish. This separation could lessen competition between the two
age classes at these areas.
4.1.2.2 Coho Salmon
A seasonal separation by age class was apparent at several sites. The
peak abundance of age 1+ fish occurred prior to the peak abundance of
age 0+ fish. This separation could lessen competition between the two
age classes at these areas.
In general, juvenile coho salmon were more abundant at DFH sites in the
lower reach of the Susitna River (Goose Creek and the Chulitna River
confluence). In the reach above the Chulitna confluen~e, juvenile cohos
were most numerous at DFH sites below Lane Creek. Two possible explana-
tions for this distribution pattern are: (1) the three sites below the
241
Chulitna provide an abundance of excellent habitat for coho juveniles or
(2) the coho juven1les were scarce in the upper reach (above Lane Creek)
during the 1982 open water season. The reason. for this scarcity is
unknown but could have resulted from the high flows of 1981 in the
tributaries where coho juveniles rear, or from severe winter conditions
during 1981-1982, or from a destructive ice-out in the spring of 1982.
The seasonal distribution of coho salmon juveniles was somewhat dif-
ferent in the reaches above and below the Chulitna River confluence.
Several sites in the upper reach showed an increase in numbers collected
in September, while several sites in the lower reach showed a decrease
in numbers during this period. The decrease in relative abundance in
the lower reach was probably caused by lowered mainstem discharge which
resulted in a loss of the mainstem backwater zone type of habitat. The
September increase in the upper reach is most likely related to seasonal
movement patterns such as the movement of juveniles out of tributaries.
The peak catches in the lower reach in July are also likely related to
seasonal migrations.
Coho salmon juveniles were most numerous during 1982 at Rabideux Creek
and Slough, Sunshine Creek and Side Channel and Birch Creek and Slough.
All three sites occur in a section of the river where the flood plain is
much broader than it is above the Chulitna River. These three sites have
low gradient streams and/or sloughs which lead to large areas of low
velocity water and (except for Birch Creek and Slough) abundant aquatic
vegetation. Further, adult cohos spawn·· in a 11 three of these creeks.
242
Of the three sites above the Chulitna River confluence which had the
largest coho juvet.ile catch in that reach, two were creeks which entered
slough systems (Whiskers Creek and Slough and Lane Creek and Slough 8)
and one was an upland slough with input from two very small creeks
(Slough 6A).
The distribution of coho salmon juveniles was similar during 1981 and
1982, as gauged by the percentage of sites where juveniles were caught
over the course of the open water season. However, the catch rates for
minnow traps in 1982 were significantly lower than those recorded at
these sites in 1981. Juvenile coho salmon were captured more frequently
at tributary mouth sites than at sites without tributaries during both
years. Six of the nine tributary mouth locations sampled in 1982 are
associated with sloughs or side channels of the Susitna Riv€r. These
tributary mouths associated with sloughs and side channels had a greater
abundance of juvenile coho salmon than tributary mouths associated
directly with the mainstem channel of the Susitna River.
The catch per minnow trap at Whiskers Creek and Slough was lower in 1982
than that recorded in 1981. Peak catches of juvenile coho salmon ages
0+, 1+, were reported in late August of 1981 and during September in
1982. Relatively high catch rat~s for juvenile coho salmon were record-
ed in the summer of 1981 and 1982 at Slough 6A. However, there was a
high catch reported in late June of 1982 which was not reported at this
site in the summer of 1981. The catch rate for coho salmon juveniles at
Slough 8A, Slough 11 and Portage Creek. located on the Susitna River
above the Chulitna confluence, was low during the open water season of
243
both 1981 and 1982. Juvenile coho catches at Fourth of July Creek were
more numerous in A:.gust and September of 1981, than during this period
in 1982. The catch per trap at Goose Creek 2 and Side Channel was lower
in the summer of 1982 than in 1981. The highest catch per trap was
recorded at this site in late August, 1981. Sunshine Creek and Side
channel recorded consistently high minnow trap catch rates of juvenile
coho salmon between June and September, 1982. Relatively low catch
rates were recorded at this site throughout the summer of 1981. Similar
high catch rates were also recorded at Rabideux Creek and Slough in
1982. Catch rate data are limited to only one sampling trip to Rabideuk
Creek in the summer of 1981. Birch Creek and Slough had relatively low
catch rates of juveni 1 e coho salmon from June to September 1982, com-
pared with catch data collected in the summer of 1981. The highest
catch per trap of juvenile coho salmon in 1982 was recorded in July.
Higher catch rates were recorded for this site from late July to Septem-
ber, 1981. The relative abundance appeared to decline during the summer
of 1982 in contrast to increasing catch rates observed during the summer
of 1981.
The distribution of coho salmon age 0+ at DFH sites in 1982 was somewhat
similar to that of 1981. The distribution of age 0+ coho salmon was
most extensive in September at sites on the Susitna River between the
Chulitna River confluence and Portage Creek. Occurrence of age 0+ coho
salmon were more consistent at tributary mouth locations in late June
and September than at sloughs. However, Slough 6A and Slough 8 recorded
significant numbers of age 0+ coho salmon in September.
244
Unlike chinook salmon juveniles, coho salmon juveniles of age class
other than 0+ were present for the. entire open water season. They were
more abundant in June and July than 1 ater on and preceded the peak
abundance of age 0+ fish at most sites.
No juvenile coho salmon fr·om brood year 1978, age II+, were observed in
the Chulitna River to Portage Creek catches during the summer, 1981. In
the summer of 1982 one juvenile coho age II+ from brood year 1979, was
captured in thi~ reach at Slough 6A.
Age 0+ coho salmon were captured at Selected Fish Habitat sites in the
upper reaches of Indian River and Portage Creek during the summer of
1981; however, no juvenile coho salmon were captured at Selected Fish
Habitat sites in these tributaries in 1982 (see Appendix Report 3-0~1).
Little can be concluded about coho salmon juvenile distribution and
abundance in the winter because of the low numbers of fish captured (a
total of 92). Either the juveniles are present at the sites only in
very low numbers or the sampling methods used in winter are not effi-
. cient. The sites sampled were mainly tributary mouth and slough sites,
with a few mainstem sites, that were accessible through open leads or
holes drilled by ice auger. Deep mainstem holes were not sampled, nor
were tributaries above their mouth areas.
The pattern of winter distribution of coho salmon juveniles at DFH sites
was not similar to the summer distribution except at the Whiskers Creek
245
and Slough site and Slough 6A where relatively high catches were made
during both season~.
4.1.2.3 Chum Salmon
Chum sa 1 man fry were caught primarily i.n June and early July. There is
no catch data from May, a time when many chum salmon juveniles were
probably outmigrating.
The catch is distributed over the entire study area in late June. The
absence of catch in the upper area reflects, in part, less sampling
effort at these sites due to logistical problems. The total number of
chum fry sampled shows a steady decrease with a significant reduction in
catch following the late June period. Also, chums were caught at fewer
sites after this period.
The catch of chum salmon fry at the Designated Fish Habitat (DFH) sites
corresponds with downstream migrant trap data for this species. The
last trap catch for chum fry was on August 15, and the last positively
identified juvenile chum caught at DFH sites was captured on August 9 at
Birch Creek slough. This fry was 39 mm in length, the same as the mean
length of chums caught at the same site during the late June period.
This may be an individual from a group which emerged late or was iso-
lated in a pool without an adequate food source and was subsequently
flushed back into the Susitna River system by an increase in Susitna or
tributary discharge.
246
Above the Chulitna River confluence, most of the sampling site sloughs
where adult chums spawned in 1981 (Slough 8, Slough 8A, Slough 9, Slough
11, and Slough 21} had relatively high catches of juvenile chums in June
of 1982. The only site where very large numbers of juvenile chums were
captured was Slough 6A. However, approximately 1,000 fish were visually
observed in Slough 8 in late June (a sub~sample was captured). Spawning
by adult chums in 1981 was observed in Slough 8 but very little spawning
by churns occurred in Slough 6A. The majority of the juvenile chums
present in Slough 6A must have come from one of the spawning areas
further upriver. This slough is an important holding/rearing area for
juvenile chum salmon. Unfortunately, it is not possible to get an
estimate of the total chum salmon juveniles present in Slough 6A; only a
small section of the slough was sampled and the water was not clear
enough for visual observation. The studies in 1983 will attempt to
provide such an estimate.
In the lower reach of river (below the Chulitna River confluence}, most
chum sa 1 man juveniles were captured in Birch Creek Slough. Chum juve-
niles were present at Birch Creek Slough longer into the summer than at
other sites. This site is probably an. important rearing area for
juvenile chum salmon. The habitat rearing characteristics for this site
and Slough 6A, will be examined in the Fish and Habitat Relationships
Report.
Winter studies indicated large numbers of chum salmon juveniles were
present in April at Sloughs 8A, 9A, 98, 11, 20 and 21.
247
The data for length frequency distribution by two week period (presented
in the downstream migrant trap results, Section 3. 2. 3) demonstrates
growth by chum salmon in the Susitna River system. Studies of the food
habits of juvenile salmon studies did not begin in 1982 until August, so
no data were collected on the feeding of chum salmon juveniles. Stomach
contents of chum juveniles will be examined during the spring and early
summer of 1983.
4.1.2.4 Sockeye Salmon
In the 1981 open water season, only 29 sockeye salmon juveniles were
caught in the area encompassed by the 1982 juvenile fisheries study area
(RM 73.1 -RM 148.8). The increased use of beach seines and backpack
electroshocking equipment in the 1982 open water season resulted in a
greater catch of sockeye salmon juveniles this season (1,432 fish).
All three sites where juvenile sockeye salmon were captured in 1981
(Birch Creek and Slough, Slough 9 and Slough 11), also produced sockeye
in the 1982 study. Sockeye salmon juveniles were captured at S1ough 9
and Slough 11 during winter sampling in 1981 and 1982.
A difficulty in analyzing catch data regarding sockeye salmon juveniles
is in standardization of catch per unit effort for the gear types which
are most effective for this species. Beach seining produced most of the
specimens caught, yet it is difficult to relate the data from one site
to the next since the morpho1ogy of the site may affect the use of the
gear. The use of the electrofishing is helpful in complementing beach
248
seining efforts, but it is difficult to compare catches from the two
gear types. By umbining catches of all gear types, the data can be
used to determine trends in the relative abundance and distribution of
sockeye salmon juveniles.
Upland sloughs such as Whitefish Slough. Slough 6A and Slough 19 all had
sockeye salmon juveniles present after the early August sampling trip.
Whitefish Slough was consistently a low producer of salmon fry, never
accounting for more than 2.0% of the total catch of juveniles of any
anadromous species. The small amount of cover in this slough may be a
factor.
Sockeye salmon fry were caught in large numbers ·in Slough 6A until
. shortly after the peak outmigration observed in early July. The signi-
ficant reduction of catch of this species tn early August in Slough 6A
and Slough 8A suggested that the majority of fry had 1 eft these 1 arge
rearing areas prior to August.
The large percentage of sockeye salmon fry taken at Slough 6A indicates
that this slough offers suitable rearing habitat for large numbers of
sockeye j uveni 1 es. Data from the adult anadromous studies project
(ADF&G 1981a, Volume II. Appendix) indicates little or no spawning by
sockeye adults at this site during 1981. This suggests that 1 arge
numbers of age 0+ juveniles moved into this habitat from upstream
spawning areas. In the early June samples, several age 1+ fish were
captured. It is unknown where these fish overwintered. The closest
slough to Slough 6A where spawning and large juveni1e catches were
249
documented was Slough 8A, 13.0 miles upriver. Tagging of pre-migrant
age 0+ sockeye srlmon fry and early season sampling is needed to
ascertain the origin of sockeye juveniles in Slough 6A. Also, more
frequent sampling during the early season would establish trends of
movement into rearing areas and subsequent outmigration.
The relative clarity of water and morphology of Slough 8A optimizes
observation (and subsequent catch) of fry during moderate to low dis-
charge situations. The catch at Slough 8A (262 fry) reflects the high
number of adult spawners in 1981 at this site (ADF&G 1981 a). The upper
reaches of this slough offer an abundance of rearing habitat. The low
discharges of 1982 appeared to reduce access to this area during the
spawning season, relative to 1981.
The upper section of Slough 8A is a system of impoundments with abundant
cover and excellent substrate for spawning and rearing. The presence of
juveniles throughout the ice-free season and the collection of age 0+
fry during winter sampling coupled with observations of adult spawning
indicates that this slough system offers important spawning and rearing
habitat for this anadromous species.
Slough 11 is somewhat similar to Slough 8A morphologically in that there
is an upper system of pools and riffles in which sockeye salmon spawning
has been extensively documented (ADF&G 1981a, Volume II, Appendix).
Fewer juvenile sockeye salmon were captured during 1982 at this site
than 1981 spawning and winter catch data (Table 3-3-24) would suggest.
250
The fry may have migrated out of the slough prior to the deployment of
efficient capture ~athods (beach seining and backpack electrofishing) in
late June.
The numbers of sockeye salmon adults observed spawning in Slough 21 in
1981 would indicate that large numbers of juvenile sockeyes might be
present during 1982. Sampling efforts produced low numbers of fry from
this slough during the 1982 open water season. This site is difficult
to samp 1 e with a beach seine, and the opening of the head in early
season periods made visual observation impossible at that time. On the
other hand, the juveniles may have left the slough prior to sampling in
June. The site was relatively devoid of vegetative cover for most of
the season. Sea gull predation in the shallow, clear water in this
slough may be a factor. Another possible explanation for the low catch
at Slough 11 and Slough 21 may be a low percentage of survival from
spawning to emergence.
Some data suggests that rear·i ng of sockeye salmon juveni 1 es spawned in
the Susitna River above the Chulitna River confluence is largely unsuc-
cessful. The Stock Separation Biology report (see Volume II, Appendix)
indicates that the sockeye salmon stock in the Susitna River above the
Chulitna confluence is not separable by scale analysis from the sockeye
stocks of the Talkeetna and Chulitna Rivers. Therefore, there is a
possibility that adult sockeye salmon migrating up the Susitna River
above the Chulitna River confluence may be strays from the other river
systems. Insufficient data on sockeye salmon was collected by the food
habitats study (Section 3.3), but sockeye juvenile stomachs collected at
251
Slough 8A and Slough 11 in August and September contained insects, as
well as the usual plankton food common to lake reared sockeye salmon
juveniles. Schools of smaller than normal sockeye juveniles were
observed and sampled in Slough 8A and Slough 19 thfoughout the summer.
The age class composition .of this year's catch of sockeye juveniles
above the Chulitna confluence (2,739 age 0+ and only 33 age 1+) could
possibly be interpreted as evidence for unsuccessful rearing. However,
age 1+ sockeye salmon may have migrated downstream below the Chulitna
River confluence prior to placement of the downstream migrant trap in
mid-June. Also, rearing could occur below the Chulitna River conflu-
ence.
Evidence suggesting the occurrence of some successful rearing exists in
the demonstrated growth rates of age 0+ sockeye salmon between March and
October (see Section 3.2.4 of this volume) and the capture of a few age
1+ sockeye juveniles above the Chulitna River confluence. The late
beginning of both the downstream migrant trapping operation (mid-June)
and of the food habits study (August 1), significantly limits the data
base available for forming conclusions concerning rearing. Also,
effective methods of capturing sockeye juveniles (beach seining and
electrofishing) were not employed in the river above Curry until late
June. The early season operation of all these studies should provide a
more complete data base in 1983. Efforts to evaluate the migration and
survival of sockeye salmon fry using coded wire tagging are also planned
to begin in early 1983.
252
4.2 Emergence and Outmigration
4.2.1 Chinook Salmon
Juvenile chinook salmon were collected at almost all study sites during
both the 1981 and 1982 field surveys (ADFG 1981b). Biological data
collected for this species during the winter surveys suggested similar
growth rates for overwintering fish during both years. The outmigration
of juvenile chinook salmon from the reach of river above the Chulitna
River confluence was observed primarily during May and June during both
1981 and 1982, and was composed predominantly of _age 1+ fish averagihg
90 mm total length. This age class was absent from the upper reach by
the middle of August. Below the confluence of the Chulitna River, age
1+ fish were observed through early September.
Age 0+ chinook salmon were collected at Indian River (RM 138.6) during
April, 1981, but this age class was not observed until early June during
the 1982 studies due to the limited sampling conducted prior to early
June. The mean length of post-emergent chinook salmon fry collected
during the 1981 spring surveys was 34 mm.
Mean 1 engths for age 0+ chi nook sa 1 man co 11 ected between the Chu 1 itna
River confluence and Devil Canyon during 1981 increased from 46 mm in
late June to 67 mm in late September. Age 0+ fish collected in this
same reach during 1982 had a mean 1 ength of 49 mm during 1 ate June and
reached an average length of 70 mm in September.
253
The adjusted cumulative catch data for juvenile chinook salmon collected
in the downstream migrant trap in 1982 is presented in Figure 3-4-9.
Although fewer juvenile chinook salmon than sockeye salmon were collect-
ed in the trap, the cumulative catches are very similar. This is
probably due to the similarity in freshwater residence of the two
species in that they usually spend one winter in freshwater prior to
outmigration.
An outmigration of age 0+ fish observed in the Deshka River during the
fall of 1980 was attributed to a size related movement (Delaney et aL,
1981). They postulated that during years of high pink salmon spawning
(even years), an abundant and available food source of salmon eggs
results in increased growth enabling age 0+ chinook fry to reach a
suitable smolting size without overwintering in fresh water. Data
collected during 1982 (another even year for pink salmon spawning) does
not show this pattern of outmigration from the reach between the Chu-
'litna River confluence and Devil Canyon. The situation may exist at
specific habitats such as the Deshka.River but was n6t apparent for the
primary study areas located between Goose Creek and Devil Canyon during
the 1982 studies.
Emergence times for chinook salmon fry was not positively determined
during the 1981 and 1982 surveys due to the lack of sampling at chinook
salmon spawning sites. However, data collected from Portage Creek
during 1981 showed that emergence had occurred prior to the sampling
conducted in mid-April. Two age classes of fish are present in the
254
100
90
::t: eo
0
~
0 70
_J
<( b 60
1--
u.
0 50
1--z
LIJ 4
0
0:::
LIJ a.
~ ·------· -. • ~ .. I .•• -·--~ . . ..,--· ---------/"'~---~-....
,""_? !'-.·
'/ ...
.· ' ~f:J
r(' ;·
•J
,1
/•
/I
I ·f·.· I •
I :
I • •
/' ) ,.
-.J' • r·;
I • 1/ .~.
I
.·
.··
CHUM
CHI NOOK
COHO
SOCKEYE
6/18 6/28 7/8 7/18 7/28 8/7 8/17 8/27 9/6 9/16 9/26 10/6 10/12
DATE
Figure 3-4-9. Adjusted cumulative catch data by species for juvenile
chinook. coho. chum and sockeye salmon collecterl in the
downstream migrant trap. June 18 through October 12.
198?.
255
Sus i tna River from the time of emergence through the period of outmi-
gration of age 1+ fish. By early August, the majority of smolts have
outmigrated from the Susitna River. The remai'ning young of year fish
redistribute from high density areas of emergence to more optimum
habitat to rear and overwinter. As indicated in Figure 3-4-9, this
redistribution continues through the ice-free season.
Surveys conducted on the Sus itna River during 1981 and 1982 show that
juvenile chinook salmon vary in abundance and distribution by seasonal
period. The migration of juvenile chinook salmon from the emergence
sites to more favorable habitat conditions begin as the fish reach a
size allowing mobility from their natal areas~· Some age 0+ fish remain
in the areas of emergence while others enter the mainstream river and
associated tributaries and sloughs to spend the remainder of their
freshwater period.
4.2.2 Coho Salmon
At least three age classes of coho salmon juveniles, ages 0+, 1+ and 2+
from brood years 1979 through 1981, were observed in the Susitna River
during 1982. Comparisons of 1981 and 1982 fish distribution data
indicate that the majority of coho salmon juveniles smolt as age 2+
fish, after spending two winters in fresh water (ADFG 1981b). The peak
outmigration of coho salmon smolts occurs between May and early June
between the Chulitna River confluence and Devil Canyon, and the peak
extends through late June in the reach between Cook Inlet and the
Chulitna River confluence. Large schools of coho salmon smolts were
256
observed at the mouth of the Deshka River (RM 40.6) on June 1, 1981, and
this schooling of ~.molts was observed on June 10 at Sunshine Creek (RM
85.7) during 1982.
Analysis of sea 1 es co 11 ected from returning adult coho sa 1 man during
1982 at the Talkeetna fishwheel survey site indicates that 59.0 percent
of the fish sampled had spent only one winter in freshwater and 41.0
percent had spent two winters in freshwater before undergoing smoltifi-
cation (ADFG 1982a). About 12 percent of the aduit coho salmon col-
lected in 1981 at the Talkeetna fishwheel survey site had outmigrated
after one year in freshwater, while 84.8 percent smolted as age 2+ fish
{ADFG 1981a). A small percentage of coho salmon spend more than two
winters in freshwater before outmigrating ~s smolts as indicated by the
co 11 ect ion of one age 2+ fish in 1 ate September, and by the recovery of
scales from returning adult fish having three or four freshwater annuli.
These data indicate a variable age of outmigration for coho salmon
juveniles from the Susitna River requiring future surveys to determine
the primary age of outmigration for this species.
Age 1+ coho salmon juveniles were collected throughout the 1981 and 1982
field seasons and a seasonal increase in mean length was recorded. By
the end of the sampling season, this age class had reached a mean length
similar to that observed for outmigrating age 2+ fish collected during
the spring.
Age 0+ fish were observed during June and were collected through the end
of the open water survey periods in 1981 and 1982. In 1981, age 0+ coho
257
salmon collected between the Chulitna River confluence and Devil Canyon
had a mean length nf 56 mm in late June. In 1982, a mean length of 41
mm was observed in late June for age 0+ fish in this reach. The
difference of 15 mm in the mean lengths for age 0+ fish recorded in 1981
and 1982 was a result of two factors: (1) a point of separation between
age 0+ and age 1+ fish during late June was determined to be 70 mm
during 1981, while the point of separation between these age classes
during 1982 was determined to be 65 mm; ( 2) the sampling techniques-
employed during 1982, including the downstream migrant trap and more
intensive use of beach seines and backpack electroshocking, were more
successful in the collection of smaller age 0+ fish.
Surveys conducted during 1981 and 1982 could not provide a time of
emergence for coho salmon fry. The lower limits of the range of lengths
for coho salmon age 0+ observed in June and July during 1982 indicated
that the emergence time for this species extends over a wide period.
The spring surveys during both years were not conducted at areas of
documented coho salmon spawning.
Comparison of 1981 and 1982 data indicates that coho salmon predomi-
nantly smolt following one to two years of freshwater rearing, and the
major outmigration from the Susitna River occurs from May through June,
although some fish do not outmigrate until late summer. Age 0+ coho
salmon undergo a downstream redistribution following emergence and this
movement continues throughout the summer. Figure 3-4-9 presents the
adjusted cumulative catch for juvenile coho salmon in the downstream
258
migrant trap and shows that this downstream migration occurs steadily
during the i ce-fre.: months. This movement is comprised of age 0+ and
age 1+ fish which are presumably moving from high density areas of
post-emergence to habitats more favorable for rearing and overwintering.
4.2.3 Chum Salmon
Surveys conducted on the Susitna River during, 1981 collected juvenile
chum salmon at only three of the designated fish habitat sites studi~d
(ADFG 1981b). The low captures of this species was attributed to the
reported short period of freshwater residence following emergence, and
the use of inefficient collection techniques {primarily minnow traps).
Additional sampling techniques used in 1982 for the collection of
juvenile salmon included beach seines, backpack electrofishing gear, and
the downstream migrant trap. Large numbers of chum salmon fry were
collected from Goose Creek (RM 73.1) upstream to Slough 21 (RM 142.0)
from March to early September. The downstream migrant trap recorded
92.7 percent of the tot a 1 trap catch of chum sa 1 mon fry from June 18
through July 15 (Figure 3-4-9).
Analysis of data collected during 1982 indicated that the major emer-
gence of chum salmon fry occurs during late February and March with most
fish completing yolk sac absorption during April at a length of approxi-
mately 35 mm. An increase in mean length occurs through June, during
which time the peak outmigration was observed. Chum salmon fry are
present above the Chulitna River confluence through early August.
259
The observed increase in mean 1 engths and in ranges of 1 engths demon-
strates that chum salmon fry in the Susitna River grow between the
period of yolk sac absorption and outmigration. A mean length of 35 mm
during April compared to the largest chum salmon fry captured (a 62 mm
fish in late July) shows a growth of up to 27 mm prior to outmigration.
An extended period of freshwater rearing for chum salmon fry occurs
following their emergence and prior to their outmigration. The low end
of the ranges of length observed following the peak outmigration in June
indicates that a broad range exists for the timing of emergence of chum
salmon fry in the Susitna River.
4.2.4 Sockeye Salmon
Juvenile sockeye salmon were collected at only seven of the DFH sites
surveyed in the Susitna River during 1982 (ADFG 1981b). A total of 35
fish were collected from March to early September from Alexander Creek
(RM 10.1) upstream to Slough 11 (RM 135.3). The low recorded captures
of juvenile sockeye salmon during the 1981 surveys was attributed to the
ineffectiveness of the gear types utilized for the collection of this
species. The incorporation of additional sampling techniques during
1982 including beach seines, electrofishing gear, and the downstream
migrant trap resulted in a dramatic increase in the collection success
for juvenile sockeye salmon.
Analysis of the combined data collected during the 1982 surveys showed a
peak outmigration of age 1+ (1980 brood year) sockeye salmon from the
reach of river above the Chulitna River confluence prior to late June.
260
Age 1+ fish accounted for a very small percentage of the sockeye salmon
juveniles collectec at this time.
Comparisons of 1981 and 1982 data indicate that the major emergence of
sockeye salmon fry occurs during March with most fish completing yolk
·sac absorption by the end of April at a length of approximately 33 mm.
A downstream redistribution of age 0+ fish from their natal streams and
sloughs occurred throughout the season with the major movement observed
during July. Over 85 percent of the adjusted cumulative catch for
sockeye salmon juveniles in the downstream migrant trap occurred by the
end of July (Figure 3-4-9).
The major portion of the age 0+ population of sockeye salmon undergo a
downstream migration from areas of emergence, but at least a small
percentage of fish overwinter in the Susitna River above the Chulitna
River confluence, based on catch data at DFH sites.
Age 0+ fish migrating out of the reach above the Chulitna River con-
fluence may continue to the ocean as age 0+ smolts, or they may migrate
to more favorable overwintering habitat associ a ted with the sloughs,
tributaries, and lake systems located in the lower Susitna River. It
appears that both situations may exist. Less than one percent of the
returning adult sockeye salmon at the Curry fishwheel camp outmigrated
as age 0+ fish while the remainder had spent one winter in freshwater
before smolting (Volume II, Appendix). This indicates that although an
outmigration to the ocean of age 0+ sockeye salmon may occur, the
survival of these smolts to the returning adult stage is very low.
261
It has also been postulated that the sockeye salmon juveniles originat-
ing in the upper ~Jsitna River may not survive to the adult stage, and
thus fail to contribute to the freshwater life cycle of the species.
Bernard et al. (1982), reported that returning adults collected at the
Curry Fishwheel Camp {RM 120.0) were not separable by scale analysis
from the stocks observed in the Chul ;_tna and Talkeetna River drainages.
Numerous hypotheses were formulated, but the probable situation was
speculated to be that the sockeye salmon adults collected in the upper
Susitna River are composed of strays from the much larger populations
entering the Chulitna and Talkeetna Rivers. The fry migrate to the
lower Susitna River to overwinter and smolt as age 1+ fish, or else do
not survive.
The questions raised concerning the viability of Susitna River sockeye
salmon stocks can be answered inpart by conducting an intensive tagging
program on sockeye salmon fry populations in the upper Susitna River and
then collect returning tagged adult fish.
4.2.5 Pink Salmon
Small numbers of pink salmon fry were collected during the 1981 surveys
of the Susitna River, and the low catches were attributed to the inabil-
ity of the collection techniques utilized to successfully capture this
species, in addition to the short freshwater residence times (ADFG
1981b). Even with the inclusion of additional sampling techniques in
1982, only small numbers of pink salmon fry were collected.
262
Two factors appear to have influenced the low catch rates of juvenile
pink salmon durins the 1982 surveys. Pink salmon fry remain in the
river system for only a short period after emergence. It appears that
the major outmigration occurred prior to the initiation of intensive
sampling in June. Secondly, the fish were from the 1981 brood class.
This was an "odd year" for adult returns and only an estimated 2,335
adult pink salmon went past the Talkeetna station (ADFG 1981a). Prel i-
minary emergence studies indicate that pink salmon emerge as sac fry
during March and some fish have a portion of the yolk sac present in
May. All fry had outmigrated from the river above the Chulitna River
confluence by late July.
The deployment of the downstream migrant traps immediately following
spring break-up, the much larger observed es~apement past Talkeetna of
adult pink salmon during 1982 (13038 fish) (Volume II), and the more
intensive surveys of spawning sites during the 1983 field season, should
provide the data necessary to determine the early life history of this
/
species in the Susitna River.
4.3 Food Habits and Distributi~n of Food Organisms
Dramatic changes in the invertebrate fauna ~ften occur below hydro-
electric projects (Ward and Stanford 1979). These changes may be
associ a ted with changes in the production potentia 1 of the downstream
reaches for important fishery resources. The following discussion
provides the initial information necessary to develop a data base
263
capable of predicting the rearing potential of mainstem, side channel,
and slough habitat~ under the post project flow.
A preliminary study of salmonid food habits in the Susitna River was
conducted in 1978 by Ri is and Friese ( 1978). They found that terres-
trial insects appeared to make the greatest contribution volumetrically
to the stomach contents of chinook, coho, and sockeye juveniles. In
their study, chinook and coho were described as having similar food
habits, whi1 e sockeye made greater use of crustacean zooplankton and
diptera larvae. The food habits of the three species became more
similar in the fal 1 (September), when the sockeye switched to eating
more adult insects.
Burger et al. (1982), in a study of chinook and coho juveniles in the
Kenai River, found that both coho and chinook juveniles relied heavily
on chironomids. Thirty-seven percent of the items in chinook stomachs
and 51% in coho stomachs were chironimds. Homopterans were also
important for chinook (15.0%), and eight percent of the items in coho
stomachs were copepods.
Juvenile salmon food habits have also been examined in several earlier
studies. Becker (1973) found Chironomidae adults and larvae made up 58
and 18 percent numerically of the diet of juvenile chinook in the
Hanford area of the central Columbia River, Washington. His results
were supported by Dauble et al. (1980) who also studied chinook in the
Hanford reach of the Columbia, and found that chironomid pupae and
larvae were the most important food item of fish under 66 rr~ in length.
264
Loftus and Lenon. (1977) obtained similar results in their study of
chinook salmon in the Salcha River southeast of Fairbanks, Alaska.
These findings generally agree with the results of the present study in
the Susitna River sloughs and tributaries where chironomids are numeri-
cally the most abundant prey taxa of the chinook salmon fry examined.
Loftus and Lenon concluded that chinook relied mainly on immature
insects drifting in the water column, rather than adults and terres-
trials drifting on the surface. In our results, and in. those of Riis
and Friese (1978), however, chironomid adults and terrestrial inverte-
brates caught on the water surface were often an important food item for
the chinook salmon juveniles (Figures 3-3-21 to 3-3-25).
Severa 1 studies have a 1 so been done on the diet of coho j uveni 1 es.
Johnson and Johnson (1981), in their study of coho at Orwell Brook,
N.Y., found that coho fed mainly on terrestrial invertebrates during the
day, and switched to aquatic forms (including adult chironomids) at
night. They fed most heavily in late evening; overall, aquatic inverte-
brates were most important in the diet. Chironomids, as immatures and
adults were the major aquatic taxa consumed (25% by dry weight).
Johnson and Ringler (1980}, in an earlier study of coho in Orwell Brook
found that usually the· coho fed most heavily on terrestrial inverte-
brates (mainly Hymenoptera, Homoptera, and Coleoptera), which made up
72% of their diet by dry weight. Their study had been conducted en-
tirely during daylight hours, and so did not reflect the diet changes in
coho food habits enumerated later. Our studies also were carried out
265
only during daylight hours, and so may underestimate the importance of
benthic invertebra~es in the coho diet.
Mundie {1969) studied coho salmon juveniles in creeks and rivers on
Vancouver Island. He found that the most frequent items appearing in
the diet were Chironomidae larvae, but that larvae of Hydropsychid
caddis flies (Trichoptera: Hydropsychidae), and nymphs of Baetis
(Ephemeroptera: Baetidae), and Ephemerella (Ephemeroptera: Ephemerel-
lidae) were most important in terms of biomass.
,The food habits of coho in the Susitna River were similar to those
described in the previous studies. The coho relied mainly on Chirono-
midae larvae, pupae, and adults {Figures 3-3-26 to 3-3-29). Terrestrial
invertebrates, however, did not play as large a role here as Johnson and
Ringler had found to be the case in New York. Johnson and Ri ngler• s
conclusions are based on dry weight measurements which were not taken
in the Susitna .. Terrestrials may have been more important by weight
than they were numerically in the Susitna studies.· The major components
of the terrestrial diet, however, were usually small aphids (Homoptera:
Aphididae), small adult Dipterans (Phoridae, Simuliidae, and Scaridae,
for instance), and sma 11 ( 1 ess than 5 mm) Hymenopterans, which probably
do not contribute much in terms of dry weight.
Most sockeye food habits studies have been conducted on lake popu-
lations. Rogers (1968), however, did study sockeye juveniles in some
streams connected to the Wood River lakes of Alaska. He found that
generally Chironomidae larvae, pupae, and adults were the most important
266
food items, though in one collection Plecoptera and Ephemeroptera nymphs
predominated. Ch:,·.pman and Qusitorff (1938) also studied sockeye in
streams and found that insects were most important. Sockeye in lakes
usually rely on zooplankton (Chapman and Qusitorff 1938, Rogers 1968).
In our studies, sockeye were only found at Slough 8A and Slough 11.
Chi ronomi dae usually were their major food type (Figure 3-3-30 and
3-3-31). On some dates, however, zooplankton became important. Since
our results are in terms of numbers, the importance of the zooplankton
may be artificially high. Zooplankton are very small and their volu-
metric contribution is not great. In August, however, the sockeye in
Slough 11 were feeding heavily on copepods and cladocerans, and these
zooplankton appeared to make a major contribution volumetrically. The
fact that this is the only time copepods or cladocerans made a notice-
able contribution to the diet suggests that the sockeye at that time
were taking advantage of a transient bloom.
Although stati sti ca lly si gni fi cant differences did often occur between
species, obvious similarities do exist in their diets. All species
relied heavily on chironomids, all consumed terrestrials to some extent,
and all occasionally consumed many other aquatic invertebrate taxa.
Sockeye were the only fish to use zooplankton in large numbers.
Because of different distribution patterns of the species, significant
differences may reflect food item availability at various microhabitats,
rather than selectivity differences of these species. There was also a
great deal of variation in food habits even within each species, pre-
267
sumably the result of individual preferences and variation in the
location of indivi::lual fish. One coho at Indian River, for example,
consumed Collembolans almo.st exclusively, probably because it happened
to be in a spot where several Collembolans were gathered on the water
surface.
Electivity values for all salmon species were usually positive for
chironomid larvae, and negative for chironomid adults. These electivity
values compare stomach contents only to the drift samples. Drift
samples collect a higher percent of surface organisms than benthic
samples do (Slack et al., 1976), and so were expected to be more compar-
able to the diets of fish which feed on invert~brates drifting in and on
the surface of the water. However, Mundie (1969) .compared the diet of
coho salmon to drift samples taken where the. coho were caught, and did
not find any close similarity between the coho diet and the drift. Such
discrepancies between invertebrate populations in the drift sarnpl es and
in the stomachs may actually be due to several factors other than food
preferences of the fish. The drift net is not as effective in collect-
ing Chironomidae larvae and other benthic invertebrates as the kick
screen is (Figure 3-3-32 to 3-3-40). It was not always possible to
locate the drift net in areas closely adjacent to where fish were
caught, so it is possible that the population observed in the drift
sample is not the same as what the fish were exposed to. The positive
selection shown for Chironomidae larvae may actually be due to prefer-
ences of fish, or it may appear only because the drift net underesti-
mated the number of larvae available to the fish.
268
Chi-square tests (Table 3-3-41) demonstrated that the invertebrate
populations at all sites were significantly different. This variability
is probably the result of major hydraulic and physical differences
between the sites.
Slough 8A is dominated by beaver dams, and the pools formed by them.
Most fish in Slough 11 were found in a shallow area containing boulders
and smaller cobble covered by filamentous algae. Waterfall Creek, a
small clear tributary, flows into Slough 20. Most of the fish from
Slough 21 were captured in shallow riffle areas.
The collections at Fourth of July Creek were usually in fast, shallow
riffles near the bank. At Indian River, the collections usually were
also in shallow riffles, but not as close to the banks.
There is also much habitat variability within each site, causing any
comparisons between sites to be confounded. Some patterns, however, can
be recognized. Slough 11, where the riffles Seemed more sluggish,
produced no mayflies (Ephemeroptera) (Appendix Tables 3-C-24 and 3-C-
25). The invertebrate samples from Slough 11 usually produced mostly
chironomids (Figure 3-3-33}, though in early September, a large number
of capniid stoneflies (Plecoptera: Capniidae) were found there.
Capniids have been reported to prefer relatively still water (Minshall
and Minshall 1977).
Samp 1 es from the tributary sites contained the most taxa of mayflies,
and a 1 so produced more taxa of Tri choptera (caddis flies) than the
269
sloughs {Appendix Tables 3-C-24 and 3-C-25). The general distribution
of invertebrate ta~a across major habitat types and the food habits of
several of the important salmonid species have been identified. Impor-
tant factors in providing quality rearing habitat for salmon juveniles
are access from original spawning areas, cover, temperature, and pre-
sence of food resources. In the sloughs of the Susitna River, terres-
trial invertebrates are important food· items, suggesting that stream
bank vegetation and 11 edge 11 may be important in providing a source for.
these food items.
For coho and chinook salmon, the range and diversity of invertebrates in
their diet suggests an ability to adapt to variable conditions. Other
factors, such as cover and velocity, may be more important in limiting
their distribution and abundance. The numbers of invertebrates avail-
ab 1 e, however, probably influence the density and perhaps the growth
rates of the juvenile fish in these habitat areas.
Sockeye juveni 1 es feed on a broad range of invertebrates, but the
presence of zooplankton in their stomach contents suggests preferences
different from the coho and chinook collected. The limited presence of
zooplankton in the sloughs may partially explain the low numbers of
sockeye found in the system. Sockeye, in their freshwater rearing
cycle, are most often associated with lakes where zooplankton are
abundant.
Chum salmon, which have limited rearing in freshwater, were not examined
during this study, but will be included during the 1983 spring investiga-
270
ti ons. This species is much more abundant in, and apparently very
dependent upon the slough areas for rearing. As freshwater rearing has
been established to affect their survival (Houston 1961), information
concerning the dependency of this species on the slough invertebrate
fauna will be valuable.
Important questions not addressed in this study, but which will be
included in the upcoming summer's work are the following:
1. How do the invertebrate communities respond to environmental
variables such as turbidity, scouring frequency, and temperature?
2. What are the habitat variables that create 11 quality" invertebrate
.·.communities and associated salmonid rearing habitat?
Providing answers to these questions should allow one to predict the
quality of mainstem and side channel environments under post project
conditions for rearing juvenile salmon.
?.71
5.0 CONTRIBUTORS
RESIDENT AND JUVENILE ANADROMOUS PROJECT LEADER
SUB-PROJECTS
Electrofishing and Radio Telemetry Study
EDITORS
Fish Distribution Studies
Food Habits Study
Incubation, Emergence, and
Outmigrant Studies
DATA PROCESSING
DRAFTING
272
Dana Schmidt
Rich Sundet
(Sub-project Leader)
Paul Suchanek
Mark Wenger
Drew Crawford
Larry Dugan
(Sub-project Leader)
Stephen Hale
Karl Kuntz
Bob Marshall
Dave Sterrit
Jim Mauney
(Sub-project Leader)
Sandra Sonnichsen
Jim Quinn
Kent Roth
(Sub-project Leader)
Dan Gray
Dana Schmidt
Stephen Hale
Drew Crawford
Paul Suchanek
Allen Bingham
(Biometrician)
Kathy Rowe 11
Gail Heinemann
Donna Buchholz
Carol Kerkvl iet
Katrine Zosel
Sally Donovan
Special thanks are also extended to the following individuals for their
assistance with R,1 studies:
1. Bob Dieryck, Maintenance Supervisor, for his assistance in design
and construction of the downstream migrant trap.
2. Steve Kreuger, Fisheries Biologis•t (AA), for help with radio
telemetry studies.
3. Fisheries Technicians, Chuck Blaney and John Gleaves, for their
assistance with identifying invertebrate samples and aging fish
scales.
4. Ann Reilly, ACC work study student~ for her help with sorting and
identifying invertebrate samples and her drafting ski 11 s.
5. Craig Heberer, work study student from Humbolt State, for his
assistance 1 ast summer with the downstream migrant trap,
electrofishing, and the fish distribution study.
273
6. ACKNOWLEDGEMENTS
We would like to express our gratitude to all the people and organizations
that provide information or assistance to the Resident and Juvenile
Anadromous studies during the past year.
We are especially grateful to Carl Burger (USFWS) for his technical expertise
and advise on radio tel~metry investigations and to all the employees at the
Anchorage ADFG, Sport Fish office for their continued help and support.
We sincerely appreciate the services provided by Acres American, Inc., Air
Logistics, Akland Helicopter, the Alaska Railroad, Rand M Consultants, Inc.,
and Gene and Rose Jenne (Three Rivers Union).
We would also like to thank Marilyn Barker (ACC) and Bjartmar Sveinbjornsson
(UAA) for their help with identification of aquatic plants.
We are grateful to Mike Kaill, Loren Flagg, Eric Hinard (ADFG) and Don
Williamson (USFWS) for their input on the· preliminary design of the
downstream migrant trap. We also are indebted to Dave Wangaard (USFWS) for
his assistance with identification of juvenile fishes and testing of
florescent pigments as marking techniques.
We would also like to extend a special thanks to the local residents and
property owners who have helped us and expressed interest in our work: Bill
Blakely, Roy Bloomfield, Mr. and Mrs. Leon Dick, Dr. Clifford H. Driskell,
Doug and Marie Dunn, Harold and Nancy Larson, and Lawrence Roberts.
274
7. LITERATURE CITED
ADFG (Alaska Department of Fish and Game). 198la. Adult anadromous
phase I species/subject report. ADFG/Su Hydro Aquatic Studies
Program. Anchorage, Alaska. 145 pp.
198lb. Juvenile anadromous fish study on the lower Susitna River.
ADFG/Su Hydro Aquatic Studies Program~ Phase I fi na 1·
species/subject draft report. Anchorage, Alaska 121 pp.
198lc. Resident fish investigation on the lower Susitna River.
ADFG/Su Hydro Aquatic Studies Program. Phase I final
species/subject draft report. Anchorage, Alaska 166 pp.
1982. Aquatic Studies Procedures Manual. ADFG/Su Hydro Aquatic
Studies Program. Phase I final draft. Anchorage, Alaska 107 pp.
Becker, C.D. 1973. Food and growth parameters of juvenile chinook
salmon Oncorhfnchus tshaw~tscha in central Columbia River. NOAA.
Fish. Bull. 7 {2): 387-4 0. . ·
Bernard, D.R., et al. 1983. Comparison of scale patterns from sockeye
salmon sampled from different rivers within the Susitna River
watershed in 1982. Alaska Department of Fish and Game, Division
of Commercial Fisheries, Statewide Stock Biology Group. 22 pp.
Borror, D.J. and D.M. Delong. 1971. An introduction to the study of
insects, third edition. Ohio State University, Columbus, Ohio.
767 pp.
Burger, C.V., D.B. Wangaard, R.L. Wilmot, and A.N. Palmisano. 1982.
Salmon investigations in the Kenai River, Alaska, 1979-1981.
U.S. Fish and Wildlife Service, National Fishery Research Center,
Alaska Field Station, Anchorage, Alaska. 181 pp.
Chapman, W.M. and E. Quistorff. 1938. The food of certain fishes of
north central Columbia River drainage, in particular, young
chinook salmon and steel head trout. Washington State Dept. Fish.,
Biol. Rep, 37A:l-14.
Daniel, W.W. 1978. Applied nonparamentric statistics. Houghton Mifflin
Company, Boston, Massachusetts.
Dauble, D.O., R.H. Gray, and T.L. Page. 1980. Importance of insects and
zooplankton in the diet of ~ -Age chinook salmon Oncorhynchus
tshawytscha in the central Columbia River. Northwest Science.
54(4):253-258.
Delaney, K.J., K. Hepler, and K. Roth. 1981 Deshka River chinook and
coho salmon study. Alaska Department of Fish and Game, Division
of Sport Fish. Federal Aid in Fish Restoration, Proj~ct AFS-49,
Vol. 22.
Fleiss, J.L. 1981. Statistical methods for rates and proportions. 2nd
Edition, John Wiley and Sons~ ~ew York, New York.
275
Geen, G.H., T.H. Northcote, G.F. Hartman and C.C. Lindsey, 1966. Life
historbs of two species of catostomid fishes in Sixteenmile Lake,
British Columbia, with particular reference to inlet stream
spawning. J. Fish. Res. Bd. Canada 23(11):1761-1788.
Hale, S.S. 1981. Freshwater habitat relationships of round whitefish
Prosopium cylindraceum. Alaska Department of Fish and Game,
Habitat Division, Resource Assessment Branch. Anchorage, Alaska.
19 pp.
Houston, A.AJ 1961. Influence of size upon the adaptation of steel head
trout Salmo gairdneri and chum salmon Onchorynchus keta to sea
water. Journ. Fish Res. Bd. Canada. 18(3):401-415.
Johnson, J.H. and E.Z. Johnson. 1981. Feeding periodicity and diel
variation in diet composition of sub-yearling coho salmon
Oncorhynchus kisutch and steelhead trout Salmo gairdneri in a
small stream during summer. Fish. Bull. 79(2):370-376.
Johnson, J.H. and N.H. Ringler. 1980. Diets of juvenile coho salmon
Oncorhynchus kisutch and steelhead trout Salmo gairdneri relative
to prey availability. Can. J. Zool. 58:553-558.
Loftus, W.F. and H.L. Lenon. 1977. Food habitats of salmon smolts,
Oncorhynchus tshawytscha and Oncor~ynchus keta, from the Sa 1 cha
River, Alaska. Pages 235-239. Department of Biology, Central
Michigan University, Mt. Pleasant, Michigan.
McPhail, J.D. and C.C. Lindsey. 1970.
northwestern Canada and Alaska.
173. 381 pp.
Freshewater fishes of
Bull. Fish. Res. Bd. Canada.
I
Merrit, R.W. and K.W. Cummins. 1978. An introduction to the aquatic
insects of North America. Kendall/Hunt Publishing Company.
Dubuque, Iowa.
Minshall, G.W. and J.N. Minshall.
invertebrates in a Rocky
55(3):231-249.
1977. Microdistribution of benthic
Mountain (USA) stream. Hydrobiol.
Morrow, J.E. 1980. The freshwater fishes of Alaska. Alaska Northwest
Publishing Company, Anchorage, Alaska. 248 pp.
Mundie, J.H. 1969. Ecological implications of the diet of juvenile coho
in streams. Fisheries Research Board of Canada. Biological
Station, Nanaimo, British Columbia, Canada. 135-152.
Pennak, R.W. 1978. Freshwater invertebrates of the United States, 2nd
Edition. Wiley-Interscience Publication, Boulder, Colorado.
Riis, J.C. and N.V. Friese. 1978. Fisheries and habitat investigations
of the Susitna River-a preliminary study of potential impacts of
the Devil Canyon and Watana Hydroelectric Project. Alaska
Department of Fish and Game, Sport Fish and Commercial Fisheries
Divisions. 128-I37.
276
Rogers, O.E. 1968. A comparison of the food ofsockeye salmon fry and
three-:,..pine sticklebacks in the Wood. River lakes, University of
Washington, Fish. Series 3:1-43.
Scott, W.B. and E.J. Crossman. 1973. Freshwater fishes of Canada.
Slack,
Bull. Fish Res. Bd. Canada 184. Otawa. 966 pp.
K.V., J.W. Nauman, and L.J. Tilley. 1976. Evaluation of three
call ecting methods for a reconnaissance of stream benthic
invertebrates. U.S. Geological Survey Journal of Research
4(4}:491-495.
Strauss, R.E. 1979. Reliability estimates for Ivlev•s electivity index,
the forage ratio, and a proposed linear index of food selection.
Transactions of the American Fisheries Society 108 (4}:344-352.
T.E.S. (Terrestrial Environmental Specialists, Inc.). 1981. Life
history and ecology of selected fishes that occur in the Susitna
River. Phoenix, New York. 59 pp.
Ward, J.V. and J.A. Stanford, editors. 1979. The ecology of regulated
streams. Plenum Press, New York, New York.
Zeibell, C.D. 1973. Ultrasonic transmitters for tracking channel
catfish. The Progressive Fish Culturist. 35(1):28-31.
277