Loading...
HomeMy WebLinkAboutPhase 2 basic data report Vol 4 Appendices A to C 1982F - - -I .... i I r r - ARLIS Alaska Resources Library &Information Services Anchorage,Alaska SUSITNA HYDRO AQUATIC STUDIES PI-IASE I I BAS IC DATA REPORT Volume 4:.Aquatic Habitat and Instream Flow Studies~1982. Appendices A - C -by- ALASKA DEPARTMENT OF FISH AND GAME .Susitna Hydro Aquatic Studies 2207 Spenard Road Anchorage,Alaska 99503 .1983 TIC f,-/:;2 5 ,c;g'~;~i t\O',!S<6fp ..... -! I APPENDIX A STAGE/DISCHARGE DATA This appendix includes mainstem discharges versus mainstem·and slough water surface elevations (pp.4-A-2 to 4-A-32);cross sectional profiles of sloughs (pp.4-A-33 to 4-A-51);mainstem,slough,and tributary discharge data (pp.4-A-52 to4-A-61),periodic water surface elevations for sloughs {pp.4-A-62 to 4-A-79);·continuous hourly streamflow and surface water temperature records for Indian River and Portage Creek (pp.4-A-80 to 4-A-177);periodic water surface elevations and measured flow at sloughs and tributaries (pp.4-A-178 to 4-A-183);and surface areas of aggregate type II hydraul ic zones at DFH sites compared with mainstem discharges {pp.4-A-184 to 4-A-187).These data were collected during the open water season in the study area located within the Cook Inlet to Talkeetna reach of the Susitna River. 4-A-l ARLIS Alaska Resources Library &InformatIon ServICes Anchorage,Alaska '~ KEY TO PLOTS OF MAINSTEM DISCHARGE OF THE SUSITNA RIVER AT COLD CREEK (STATION NUMBER 15292000; USGS,1982b)vs.WATER SURFACE ELEVATION AT SELECTED SITES ABOVE TALKEETNA (FIGS.4-A-l to 4-A-30). II) of gages *=streamb~d el~vation of the slough at gage s~te.Cage observed dry for these mainstem discharges 0=observed water surface elevation at gage site for themainstem dis- charge on date of observation B Lo/ticn HEAD or WHISKERS CREEK iLOUGH F:ri 1l)1.6 ' ...r; ~A~ to 31,900 cfs WSEL =10-3.5307 Q.9156 +365 A .1.\I I f I I I I ~J I I I ,t I I .~ 1,000 \5,000 leleee 20,000 50,000 le0,eee MRIH$TEM DISCHRRCE~T GOLD CREEK 1100B cf.) \~"Mean daily" Equation for indicated range of mainstem discharge discharge;WSEL in feet,0 in cfs. Example For a mainstem discharge of 20,000 cfs,the equation for line "B"is used: WSEL(feet)=10-3.5307 20,000.9156 +365 =367.6' .... Cl) Cl)... V\ \ll,.., 'ace +- ....J W cI) ~ ~ .j::> I ):> I N J I J ~t J -] ) J J j J J J !I ) J D ) j J ---_._) ) I 1 1lIi '---1 1 j ) ----~ 10 .... CIl CIl.... U"I U"I.....+ ...J lIJIII . ~ o s 8.440 to 24.000 cfs Equation:WSEL =10-1.1197 0.4706 +355 LEfT BRHK ~T LRX-6 R/'I191.0 .p- I )::0 I W 10 .... CIl CIl.... o \D.....+ ...J. lIJ III ~ I I I I I I I I~I I I 10 /'IAIHSTEM DISCHAR~E AT ~OLD CREEK 11090 cfs) 100 a =7.950 to 25.600 cfs Equation:WSEL =10-1.8238 0.5800 +360 MRIHSTEM AT WHISKERS SLOUGH RM 1.01.0 10 MAIHSTEM DISCHARGE RT ~OLD CREEK 11090 cfsl 11)l'! Figure 4-A-l ..r~ainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at left bank of LRX-6 and Whiskers Creek Slough. 10 ..., Ql Ql... N S l_A.. ~0 =6;900 to 11.100 cfs~Equation:WSEL =10.1.5912 0.5375 +372 _8_ o =11,100 to 32.500 cfs Equation:WSEl =10-2.1089 Q.6655 +372 TRLKEETNR rISHWHEEL RM le3.e ~ I l> I ~ I~ MRiNSTEM DI$CHRRQE AT GOLD CREEK 11eee ct., 10 10e ..., :l... 11'1....~ ..J loJ l/):.: 0=7,950 to 16,000 cfs Equation:WSEl =10-3.2308 0.9298 +375 19 MRINSTEH DISCHARQERT GOLD CREEK Ileee ct., RIGHT tRNK AT LRX-? lUI 103.2 100 J I J ) Figure 4-A-2. J J Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface ele\l\tion at Talkeetna Fishwheel Camp and r;ght bank of LR ,. ~J J I I J I J J _J ) J l ) Ie ""--1 ----1 ----. ) ~--,---5 ---,, ~vv.... tI) 4- 1: ~ W II) ~ o =8.440 to 24.200 cfs Equation:WSEL =10-.6137 0.2960 +445 SIDE CHANNEL AT GASH CREEK RM 111.5 ~ I )::- I U1 Ie ~ II>v.... o tI) 4-+ -l W II) ~ Ie MAIHSTEM D.ISCHARGE AT GOLD CREEK (Ieee cfs}' 100 0=7.950 to 24.000 cfs Equation:WSEL =10-1.2884 0.4648 +450 HEAD GRSH CREEK SIDE CHAHHEL RM 112.1 100 I I I I I I I I~I I I I I I "1 Ie MAIHSTEM DISCHARGE RT GOLD CREEK 1leeects) Figure 4-A-3.Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at side channel of Gash Creek and head of Gash Creek side channel. 10 ...., .Ql Ql.... o l1'l .".+ ..J W VI ~ o =8,960 to 32,000 cfs Equation:WSEL =10-.7857 0.3768 +450 MRINSTrM RT SLOUGH 6R RM 112.3 .$==0 I )::> I 0' 10 ...., Ql Ql.... :g .".+ ..iW ~ Ie MRINSTrM DISCHRRGr RT GOLD CRrrK (Ieee ct,l A o =7,950 to 13 ,100 cfs Equation:WSEL =10-1.18990.4831 +455 B o =13,100 to 24,000 efs Equation:WSEL =10-.7079 0.3661 +455 RIGHT BRNK LRX 19 RM 113.e lea Ie "RIHSTr"DISCHARGE RT GOLD CRrrK 11eee ct,) I J ) ,/ I .J .1 Figure 4-A":'4. 5 .J lee Mainstem discharge (Provisional USGS 1~82b)versus mainstem water surface elevation at Slough 6A and right bank of LRX-18~ t J J III J J .1 , J J --).~)---1 •-J --1 ) I J ] ) 1 18 -r-I----------------,--......------------------~------___, .j.J CIl CIl..... o N ll\+ -'w V'l 3: A o =10.500 to 14.000 cfs Equation:WSEL =10-6.4384 01.6196 +520 B o =14.000 to 32.500 cfs Equation:WSEL =10-3.9604 01.0217 +520 Curry Fishwhee I, RM 120.6 +:> I )::0 I-a 10 .j.J CIl CIl..... 10 MAIHSTEM DISCHARGE AT GOLD CREEK 11000 cfsl D 100 10 MAIHSTEM DISCHARGE RT GOLD CREEK (1000 cf~J o N ll\+ -'w V'l 3: o =7.950 to 24.100 cfs Equation:WSEL =-5.3321 01.3674 +520 RIGHT BRHK LRX-24 RM .20.7 100 Figure 4-A-5.Mainstem discharge (Provisional USGS 1982)versus mainstem water surface elevation at Curry Fishwheel Camp and right bank of LRX-24. 19 +J lI.l lI.l It- o U"I U"I+ -J W til 3= A o ,;"8,480 to 13,00 cfs Equation:WSEL =10-2.8296 0.8344 +550 B o =13,000t924,100 cfs Equation:WSEL =10-4.3455 Q1.2D30 +550 ~.r t'AV ~ RI~HT BAHK ~RX~29 RM 124,4 ~. I ):;> .1 CO 10 10 MAIHSTEM DICHAR~E AT ~O~D CREEK (1990 cts] B~ 10,9 RIGHT BRNKLRX-29 RI1 126.1 .~ ~'r A A o =7,950 to 13,300 cfs Equation:WSEL =10-2.8633 0.8719 +565 B o =13,300 to 24,000 cfs Equation:WSEL =10-1~2668 0.4847 +565 I I I I I I I~.1 I f I I I "1 10 IO~ M~INST(M DISCHRRGE RT GO~D CREEK (1090 cfs) +J lI.l lI.l 'I-' U"I <D U"I+ -Jw· VI 3= J J I J Figure 4-:-A-6. J J Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at right bank of LRX-28 and right bank of LRX-29.l . J J I I I I )J .I , J J i i J J -1 1 J )1 -J 1 ----1 ---~)J ) 10 -...., II) 10- o 0'> '"+ ...J llJ VI ~ A 0=7,950 to 14,500 cfs Equation~WSEL =10-1.4229 0.5454 +590 B o =14,500 to 24,100 cfs Equation~WSEL =10-.5979 0.3471 +590 10 MRIHSTEM DICHRR~E RT ~OLD CREEK (1000 ctsl RI~HT BRHK LRX-31 RM 128.7 1M r;;::"r~A -+::- I ::t» I I.D 10 -... II) OIl IO- M-'"+ ...J llJ VI ~ A 0=7,950 to 13,100 cfs Equation~WSEL =10-3.4391 0,·0041 +613 B Q =13,100 to 32,000 cfs Equation~WSEL =10-1.5683 0.5498 +613 RIGHT BRHK LRX-35 RM 130.9 10 MRIHSTEM DISCH~R~E RT GOLD CREEK (1090 cfsl 100 Figure 4-A-7.Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at right bank of LRX-3l and right bank of LRX-35. ..~ -4-' t.... o ::[ A ~- ~0 =7,950 to 14,700 cfs ~Equat;on:WSEL=10.0087 0.1812 +610 B o =14,700 to 32,000 cfs Equation:WSEL =10-1.4243 0.5250 +610 I--A-1 ~~~B MAINSTEM AT rOURTH or JULY RM 1J 1 .1 10 MAINSTEM DISCHAR~E AT ~OLD CREEK (1000 ct.) 100 +>0 I ):- I.....o ~_-------------------------------=;==----------ll10I 4-' 1Il 1Il.... o '"'f --I W ~ A 0=7,950 to 16,109 cfs Equation:WSEL =10-.9915 0.4286 +650 B o =16,100 to 32,000 cfs Equation:WSEL =10-.2467 0.2516 +650 LEfT BANK LRX-40 RM 134.3 10 MAINSTEM DISCHAR~E AT GOLD CREEK (1000 cfsJ 100 ~I ;el I Figure4-A-8.Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface ele"-fion at Fourth of July Creek and left bank of LRX-40. JJ I J )J eel I J I ) I ...j ) 1 -1 j J ~J 1 ]]-],....J 1 ')")) 10 +J CIl CIl..... ~ .~ ? o lD lD+ ...J U..J Vl 3 I-A 0=7,950 to 12,300 cfs Equation:WSEL =10-1 ,0979 0,4726 +660 B 0=12,300 to 16,000 cfs Equation:WSEL =10-1 ,8301 0,6531 +660 I I I t I I SIDE CHANNEL BELOW MOUTH SLOUGH II RM 135,3 I 10 MAINSTEM DISCHRR~E AT ~OLD CREEK lleeo cfsl 100 .+::> I J;oo I f-' f-' 10 (~I ...., CIl CIl..... o lD lD+ ...J U..J Vl 3 o =7,950 to 28,000 cfs Equation:WSEL =10,0880 0,2024 +660 SIDE CHANNEL ABOVE MOUTH SLOUGH II RI1 135.3 18 MAINSTEM DISCHARGE AT GOLD CREEK (IOeO cfsl lae Figure 4-A-9,Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at side channel below mouth of Slough 11 and side channel above mouth of Slough 11, 10 ..... II> II>..... ~ ~[A ...I UJ ~ o =7.950 to 13.500 cfs Equation:WSEL =10-3.4613 01.0172 +691 B 0=13.500 to 31.900 cfs Equation:WSEL =10-1.69700.5902 +691 MRIHSTEM RT MOUTH SLOUGH I.B RM 137.9 10 MRIHSTEM DISCHRRGE RT GOLD CREEK 11900 Ct5 . 100 ..p. I::r:- I-N Ht ..... II>.,..... III (J'> \D+ -'w VJ 3: 0=13.400 to 31.900 cfs Equation:WSEL =10-.8157 0.4024 +695 MRIHSTEM RT HERD Of SLOUGH 16B RM 139.3 Figure 4-A-10.versus mainstem and head. J ) J J J j ) 10 MRIHSTEM DISCHRRGE RT ~OLD CREEK [1000 C'5) Mainstem discharge (Provisional USGS 1982b) water surfaCeelP\{ftion at Slough 168 mouth ,J I I J I I 100 ,\ I J I 1 I 1 )J i J ]])J j J)_J ) 10 i I +' III III.... oo r-+ -'W <fl... A Q =1,950 to 17,700 cfs at Gold Creek Equation:WSEL =10-4.185~Q1.1~79 +100 B Q =17,100 to 21,500 cfs at Gold Creek Equation:WSEL =10-1.0234 0.4034 +700 A V LEFT BRHK LRX-Se RM 138.6 10 MRIHSTEM DISCHRR~E RT ~OLD CREEK (Ieee cfsl loe -+:> I :;b I..... W 10 .u III <lJ.... '"o r-+ -J W </) > A Q =1.950 to 15,200 cfs at Cold Creek Equation:WSEL =10-3.2678 0·91~3 +705 B o =15,200 to 24,100 cfs at Cold Creek Equation:WSEL =10-2.5836 0.7507 +705 LEFT BRHK LRX-Sl RM 138.9 Ie MRIHSTEM DISCHRR~E RT GOLD CREEK (le0e cfsJ lee Figure 4-A-ll.Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at left bank ofLRX-50 and left bank of LRX-51. 10 ... 4> 4>.... In... '"+ ..J W If) )I: ~ Q =7,950 to 13,600 cfs at Gold Creek Equa1:fon:\115El =10-1.5428 Q.5535 +715 B o =13,600 to 32,500 cfs at Gold Creek Equat;on:\115El =10-.8185 0.3783 +71'S MAINS1EM AT SLOUGH 19 RM 139.8 10 i I 16 I1AIHsrEI1 DISCH~RGE A'T ';OLD CREEK (Ulile c fsJ.po I" ", I ~.po .... 4> tl.... o '"'+ A~I 0:7,950 to 16,800 cfs at Gold Creek )I:~Equat;on:WSEl =10-2.83290.8263 ""720 B Q =16,800 to 31,900 cfs at Gold Creek Equat;on:WSEl'"10-1.6400 Q.S440 +720 RIGHT BANK LRX-53 R11140.1 1'00 Ie I1AINSTEM'lJISCHARGE RT GOLD CREEK neee 'Oh) 10e J I J J Figure 4-A-12.Mainstem discharge (Provisional USGS 1982b)versusmainstem water surface e1"'ftion at Slough 19 and right bank of LRX-53. I J I ~I I I J J I )) \ J J ) 1 J 1 1 J .~.~-J ._-)-)1 J ) J j 10 .., III III....------ 1/'\ N.....+ ..J W V> :;E Insufficient data obtained in 1982 for development of a rating curve equation. I I I __1.I ,I , MAINSTEM AT HEAD SLOU~H 20 RM 140.6 1 ')010 MAIHSTEM DISCHAR~E RT ~OLD CREEK (100e cfs) Ililt'------~---I +:> I ::t=> I...... tJl ... III III.... o...,.....+ ..J IJJ Vl 3: A 0=11,000 to 17,600 cfs at Gold Creek Equation:WSEL =10-5.609801.4376 +730 B 0=17,600 to 27,500 cfs at Gold Creek Equation:WSEL =10-2.4385 Q.6906 +730 A f MAIHSTEM AT LRX-S4 RM 140.8 llil MRIHSTEM DISCHRRGE AT GOLD CREEK (1000 chI 100 Figure 4-A-13.Mainstem discharge (Provisional USGS 1982h)versus mainstem water surface elevation at head of Slough 20 and at LRX-54. A --l IJJ ~ .... III III.... a:l ~ -------------------------------;----------~I10-, o =13,900 to 28,200 cfs Equation:wsn =10-1.52580.5277 +7'18 RIGHT BANK LR~-56 RM 142 .•1 10 i i ~ I ):> I....,.. O'l 10 MAINSTt:M DISCHARGE AT G.OLD CREEK (1000 ~fs) 100 .... III III.... o III '+ --l I Aw -~O =12.400 to 14.000 cfs Equation:WSEL =10.11.1987 02.8118 +750 B Q =14.000 to 32.500 cfs Equation:WSEL =10-3.1823 0.8787 +750 RIGHT BANK LRX-57 RM 142.3 10 HAINSTEH DISCHRRGE RT GOLD CREEK (1000 ~f5) 100 Figure 4-A-14. ),I ,I )I J Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elpvltion at right bank of LRX-56 and right bank of LRX-57., J J ]JJI J J I " •) J J ')J "]1 "J 1 1 1 J J ]1 J 1)) 1e ..... Ql Ql.... I~ oc:o,.... + ~ lJJ Vl 3' A 0=7,950 to 13,500 cfs Equation:WSEL =10-3.2366 0,9829 +780 B 0=13,500 to 31,800 cfs Equation:WSEL =10-,8663 0,4091 +780 MRIHSTEM RT HERD SLOUGH 22 RM 144.7 100 LErT B~HK RT LRX-61 R~l 149.7 10 MRIHSTEM DlSCHRR~E RT GOLD CREEK (1000 cfsJ A 0=13,400 to 21,300 cfs Equation:WSEL =10~2,5442 0,7683 +830 B 0=21,300 to 31,800 cfs Equation:WSEL =10-.7839 Q,3617 +830 I I I I'I I~I I I I I I III Ie 100 MRIHSTEM DlSCHRR~E RT ~OLD CREEK (Ieee cfsl o Mc:o+~ ~ lJJ Vl 3' ..... Ql Ql.... 10 .p- I :> I I-' "-J Figure 4-A-15,Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at head of Slough 22 and left bank of LRX-6l. ~ I :l> I I-'co 1 (. ..., ell ell.... o ,." a:>+ ...J W V) 3: ~.~ Q =13,400 to 24,100 cfs Equation:WSEL =10-1.37850.5306 +830 I I I I I I I .1..-1 I 10 MQINSTEM DISCHARGE AT GOLD CREEK 11000 <tIl LEfT E~HK ~T LRX-62 RM 148.3 I ---L--1 I II 10': Figure 4-A-16.Mainstem discharge (Provisional USGS 1982b)versus mainstem water surface elevation at left bank of LRX-62. )~ 8 J J !J J ,J j J .~I I J I I J ! --1 ''1 .~J J 1 1 .']1 J )J i -)) 10 ..., 1Il 1Il.... o III ~... oJw I/l:;c I0 ~8.440 to 14.100 cfs Equation:WSEL =10-.9549 0.4237 +450 B Q =14.100 to 32.000 cfs Equation:WSEL =10-.5367 0.3229 +450 ~~ ~ MOUTH or SLOU~H 6R RM 112.3/GR~E 112.3WI IGe ~ I ):00 I ~ \.0 18 --j "I I I I I~I I I ,I'"I 18 MRINSTEM DISCHRR~E RT ~OLD CREEK 11eee cfsl ..., 1Il 1Il.... l/l ....+ oJ W I/l:;c A 0=11.700 to 14.900 cfs Equation:WSEL =10-1.0372 0.3919 +715 B 0=14.900 to 17.700 cfs Equation:WSEL =10-6.1732 01.6227+715 C 0=17.700 to 31.800 cfs Equation:WSEL =10-1.60850.5479 +715 1:1 MOUTH or SLOU~H 19 RM 139.8 Ie MRINSTEM DlSCHRR~E RT ~OLD CREEK IIee0 cfsl 100 Figure 4-A-17.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at Slough 6A mouth and Slough 19 mouth. 10 .... tJ tJ... o ID,.., + -oJ W ~ o "'8,440 to 31,900 cfs Equation:WSEL"'10-2.0995 0.6478 +360 MOUTH OF WHISKERS SLOUCH RM 101.2 ~ I J::> I No Ie .... 4J tJ '"- Ie MAIHSTEM DISCHAR'E AT 'OLD CREEK Ileee cfsl ~~a_~ ~A --=--.J lee o ID,.., + -oJ W Vl 3: A o e 8,440 to 17,800 cfs Slough not breached,rating curve equation not developed. B o =17,800 to 25,600 cfs Equation:WSEL"'10-.4150 0.2743 +360 MID-SLOUGH Q SITE AT WHISKERS CREEK RM 101.4 la MA1HSTEH DISCHAR'E AT ~OLD CREEK lleee cfsl Ilia ~J .1 j Figure 4-A-18. .~J Mainstem discharge (Provisional USGS1982b)versus the w~ter surface levation at Whiskers Slough mouth and m'f-s1nlJjh.J J J ...J J J \ 1 1 1 )-)1 ___.J ,.--..)1 )J 1 1 1 J~ ) 10 .... Gl II:.... ~ I» I N..... IJ') <D M + ...J W <Il ~ A o =14,440 to 17.800 cfs Slough not breached,rating curve equation not developed. B Q =17,800 to 31,900 cfs Equation:.WSEL =10-3.5307 Q.9156 +365 HEAD OF WHISKERS CREEK SLOUGH P~l 101.6 I I I I I I I I~I I I I I 1111 1 e I eo MAIHSTEM DISCHARGE AT GOLD CREEK (Ioee ~fs) Figure 4-A-19.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at head of Whiskers Creek Slough. 10 ..., a.>a.>.... U"l <D <t+ ..J lJJ Vl 3= Insufficient data obtained in 1962 to develop raUng curve equation. o ~--j/ MID-SLOUGH Q SITE RT LANE C~EEK RM 113.6 oj:» I )::0 I N N Ie I , I I I J I I 10 11RIHSTEM DISCHARGE t=lT ';OLD CREEK (Ieee c fs) I I lee ..., a.>a.>.... o t- 4-+ ..J lJJ Vl 3= Insufficient data obtained in 1962 to develop rating curve equation. ~ / / / /.." HERD OF LRHE CREEK SLOUGH RM 114.1 I J Ie MRIHSTEM DISCHt=lRGE RT GOLD CREEK 11000 cfs) USGS 1982b)versus the Creek Slough mid-slough .~ , ,>" .1 ), Figure 4-A-20. J .J I I I I I I I I Mainstem discharge (Provisional water surface Q\l evati on at Lane and head.,. I J J I I t J 100 J , I j J 1 1 1 1 1 1 1 J ]1 ~J-J 10 10 I I I I I I I I I I I I I ..... Gl <l>..... l!'l '"\0+ ..J W V) ~ A Q ~11,700 to 13,300 cfs Equat;on:WSEL =10-8.5094 Q2.1701 +665 B Q ~13,300 to 27,500 cfs Equat;on:WSEL ~10-2.5821 Q.7333 +665 I V A ~A ~B . MOUTH or S~OUGHll RM 135.3 lee -+::> I :t:o I N V) 10 ..... II> QJ..... Il\ '"'"+ ..J W V) ~ MAIHSTEM DISCHARGE AT GO~D CREEK 1100e cfsl / / / HIID ..I Breached cond;t;on not observed ;n 1982,rat;ng curve equat;on not developed. MID-SLOUGH Q SITE AT SLOUGH 11 RM 136.7 1 10 MAIHSTEM DISCHARGE AT GO~D CREEK 119ge cfsl lee Figure 4-A-21.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at Slough 11 mouth and mid-slough. 10 ~ .j..l vv..... oco \0+ /--I I I ___......-.••..J .;:,. I »0 I N.;:,. ...J u.J <f> 3= Breached condition not observed in 1982,rating curve equation not developed.HEAD OF SLOUGH 11 RM 136.5 10 MAIHSTEM DISCHARGE AT GOLD CREEK (1000 cfs) 1"0 Figure 4-A-22.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at head of Slough 11. ~)\ "j J I J )I t I I }}J J ,J J J I j 1 J --I ----j --)J 1 i J -j ~J 1~ .... 4> 4>..... 100 MOUTH or SLOUGH 16B RM 137.9 c f.-A4oj A 0=11,700 to 19,500 cfs Slough not breached,rating curve equation not developed. B o =19,500 to 31,900 cfs Equation:WSEL =10-7.6919 Q1.8731 +695 I I I I I I I I~I I I 1'1 "1 Ie \t'I <To \D+ -'w Vl 3' MRIHSTEM DISCHRRGE RT GOLD CREEK (1000 cfsl ..j:::o I :J:::o I N U1 10 .... 4> 4>..... ~~r-A~ '"$ + -'wen ~ A o =",700 to 20,200 cfs Slough not breached,rating curve equation not developed. B o =20,200 to 28,200 cfs Equation:WSEL =10-2.2513 0.6867 +695 MID-SLOUGH Q SITE AT SLOUGH 1GB RM 138.0 I I I I I I I I 10 Mf=lIIlSTEM DISCHf=lRGE IH ;OLD CREEK (1008 ':tSI I I I I I I 10e Figure 4-A-23.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at Slough 168 mouth and mid-slough. ~ I ):0 I N 0'1 10 ..., vv.... oo..... + -J W til 3:: A o =13,600 to 19,500 cfs Slough not breached,rating curve equation not developed. ----L 0=19,500 to 31,900 cfs Equation:WSEL =10-3.4230 0.9094 +700 s,A·..~.. ~A~ HE~D or-SLOUGH 16B RN 138.3 I I 10 M~IHSTEM DISCH~R~E ~T ~O~D CREEK (10e0 cfsl 100 Figure 4-A-24.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at head of Slough 168. I ) .1 __1 ]t J I J ..~s J J ) I J I 1 1 I •--1 J 1 ])]-j J I j l Ie .... 11/ 11/.... o N';I A-,-- ~0 =8,480 to 16,300 cfs ~Slough not breached,rating curve equation not developed. B o =16,300 to 32,500 cfs Equation:WSEL =10:1.8815 0.5958 +720 MOUTH Of SLOUGH 20 RH 140.1 -I:> I )::- I N....... .... III ".... fe Ie t1AIIlSTEI1 DUCHARl;E IH '.OLD CREEK (Ieee c fsl \-r-B4 A.I lee o N.....+ ~ lJ.J Vl ~ A o=8,480 to 20,200 cfs Slough not breached,rating curve equation not developed. B o =20,200 to 32,500 cfs Equation:WSEL =10-.3054 0.2656 +720 MID-SLOUGH Q SITE AT SLOUGH 20 RM 140.2 Ie I1AIHSTEti DISCHARl;E AT GOLD CREEK (Ieee cts) lee Figure 4-A-25.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at Slough 20 mouth and mid-slough. ~ I J» I Nco 1e -~ III Q,).... 11"1 ('I,... + ~ I.JJ Vl ~ I- A o =12.500 to 20.200 cfs Slough not breached.rating curve equation not developed. B o =20.200 to 32,500 cfs Equation:WSEL=10-.9871 O·~062 +725 I I HEAD or S~OU~H 2e RM 140.5 I 1e MRIHSTEM DISCHRR~E RT GO~D CREEK (lee0 cfsl 100 Figure 4-A-26.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at head of Slough 20. .~\,J j )J ))J ]J .1 I ~I I _.J I I 1 --1 _...~....~~·--·-l 19 1 ]···--1 ) -I -) j .... 41 41.... o ~,.... + ...J W '"~ A o ~12.500 to 23,200 cfs Slough not breached.rating curve equation not developed. B o =23.200 to 32,500 cfs Equation:WSEL =10-3.2714 Q.9039 +740 ,;.j -..".Y~A·~ MOUTH OF SLOUGH 21 RM 141.8 +:0 I;po I N <.D 18 .... 41 41.... I- t 10 HAIH$TEM DISCHARGE AT ~OLD CREEK 11999 ctsl ~rB a ~ar---A ~ 199 o ~,.... + ...J W '":J< A o =11.000 to 24.600 cfs Slough not breached.~atlng I-curve equatIon not developed. B o =24.600 to 32.500 cfs Equation:WSEL ~10-4.123001.0976 +140 I I I I I I I I MIO-SLOUGH Q SITE AT SLOUGH 21 RM 141.9 IT 19 HAIHSTEH DISCHARGE AT ~OLD CREE~(Ieee efsl t09 Figure 4-A-27.Mainstem discharge (Provisional USGS 19S2b)versus the water surface elevation at Slough 21 mouth and mid-slough. 10 ..., eueu..... o U'1 I"-+ ~w ~ I- A o =16.000 to 24.600 cfs Slough not breached.rating curve equation not developed. B o =24.600 to 32.500 cfs Equation:WSEL =10-1.90960-5858 +750 I ,,,,,,l'I r-Bj, ~. N.W.HERD OF SLOUGH 21 RM 142.2 I I I I ~ I ):::0 I Wo 10 ..., eueu..... o III I"-+ -'wrn ~ 19 MRINSTEM DISCHRRGE RT ';OLD CREEK 11000 cfsl ..."([;"'~' 100 Insufficient data obtained in 1982 to develop rating curve equation. N_E.HERD or SLOUGH 21 RM 142.3 19 HRIHSTEI1 DISCHRRGE RT ';OLD CREEK (1000 c fs) 100 J ) a J ~ Figure 4-A-28. J J Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at the NW and NE heads of 510ugh 21.} _J .._J~_j a cJ J J \ J 1 1 i 'I ]1 1 J ].-J J 1 J J i ))) 18 .j.> ill ill....., I'- I'-+ ~ W lI'l 3' A 0·11,000 to 22,700 cfs Slough not breached.rating curve equation not developed. B o•22,700 to 28.200 cfs Equation:WSEl.10-2.2340 0.6853 +775 rB.I _'aD 1:1 ~I+-A~ MOUTH OF SLOUGH 22 RM 144.2 +:> I :P I W..... 18 10 MRIHSTEM DISCHRRGE RT GOLD CREEK (1000 cfsl 100 .j.> 4> 4>..... oco I'-+ ~ W lI'l::c A o =13,600 to 22,000 cfs Slough not breached.rating curve .quation not developed. B o =22,000 to 28,200 cfs Equation:WSEl =10-5.0236 01.2826 +780 MID-SLOUGH Q SITE RT SLOUGH 22 RM 144.6 I I I I I I I~I I I I 1"'1 10 100 MRINSTEM ~ISCHRRGE RT GOLD CREEK (1000 ,15) Figure 4-A-29.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at Slough 22 mouth and mid-slough. .+:> I ):> I W N .j.I CU II).... LI'\ <0......+ ...J lJ.J If) 3: 10 A o =13,600 to 20,700 cfs Slough not breached,rating curve equation not developed. B Q =20,700 to 28,200 cfs Equation:WSEL =10-5.2485 01.3196 +785 );/rS?,Q.....~ r--A~ HERD or SLOUGH 22 RM 144.7 10 MRIHSTEM DISCHRR~E ~T ~OLD CRE~K 11000 ~fs) 100 Figure 4-A-30.Mainstem discharge (Provisional USGS 1982b)versus the water surface elevation at head of Slough 22. }'., .1 )1 ....J J j I )J .~~I J I ]j 1 -1 ~~l 1 ---1 1 j -]1 -)1 -1 1 )) HEAD 314;RM 101.6 362 MOUTH RM 101.2 MID-SLOUGH RM 101.4 20 40 60 eo 100 120 140 CHANNEL WIDTH (feet) 368 3641 I I -I I I I o 20 40 60 eo 100 CHANNEL WIDTH (feet) z o 312 ~<t 370 > LLI ...J LLI LLI :;) cr I I 1~366i I I I I I o .. II> II> oj::> I» I W W --SUSfTNA Rf VER--.360 ,iii iii I o 20 40 60 60 100 120 140 -,c~:.;;.~,:·-..,.-.:.7t::i·:;~:~:.~';';..~.~:.",:::::;:"~.::....~:~MOUTH :HEAD :,'WHISKERS CREEK SLOUGH OBsERVAT ION DI SC HARGE (cfs) (WSEL)SlouOh Moinslem A 35.1 24,000 B 0.2 15,600 C 2.0 8,470 CHANNEL WIDTH (feel) Figure 4-A-3l.Cross sections of the head~mid-slough and mouth of Whiskers Creek Slough depicting the water surface elevation corresponding to the slough and mainstem discharge. ~ ~SU$ITNA RI vf R - MID-SLOUGH RM 113.6 468 466 1 I i I I I I I --, o 20 40 60 80 lOa 120 140 160 CHANNEL WIDTH (feet) DISCHARGE (cf s) Slough Mainstem 20.8 32,000 9.9 24,000 2.I 14,600 LANE CREEK SLOUGH OBSERVATION (WSEL ) A B C q,;478l HEA [) Q)RM 11.4.1:=. z Q 470~ ct> U.J -.J 474 I A U.J U.J ::> Cl:: ~472 I , ,I , , , 160 200 I 0 20 40 60 80 100 120 140 180 220 CHANNEL WIDTH (feet) 470 .+:> I ):>, W.+:> Figure 4-A-32.Cross sections of the head and mid-slough of Lane Creek Slough depicting the water surface elevation corresponding to the slough and mainstem discharge. )\ J I I I I _J J I J ,I _l J J J J J J 1 ~··--i ]J J I J 1 1 1 1 1 ~1 1 ""J )) 682 690 68a 686 1;84 HEAD RM 136.5 o 20 40 60 eo 100 120 140 160 180 200 220 CHANNEL WIDTH (feet) / 680 SLOUGH II OBSERVATION DISCHARGE{cfs) (WSEL)Slough Mainstem A 5.5 27,500 A '<{ MOUTH RM 135.3 666 20 40 60 80 100 120 140 160 CHANNEL WIDTH (feet) MID-SLOUGH RM 135.7 668 I I I iii I IiIo 670 w ~cr 672 f- --ww :::678 zo ;::676~w ~674 13,1003.\B +:> I:r:- Iw tJ1 664 I I I I I I Iii I I o 20 40 60 80 100 120 140 160 180 200 CHANNEL WIDTH (feet) Fi gure 4-A-33.Cross secti ons of the head,mi d-s lough and mouth of 510ugh 11 depi cting the water surface elevation corresponding to the slough and mainstem discharge. f MID-SLOUGH SLOUG H ACCESS RM 137.8 '....I c --.....,: B Slough 168 -SUSlrNA RIVER_ ,: A MOUTH RM 137.9 .696 I I I I 111'I I I I I I I ro204060eo1000204060eo100120140 CHANNEL WIDTH t feet) MID-SLOUGH RM 138.0 SLOUGH 168 OBSERVATION DISCHARGE (efs) tWSEU Slough Moinstem A 257.6 28,200 20 40 60 80 100 120 140 160 180 200 CHANNEL WIDTH t feet)70 698 Iii iiio20406080 ILl :J i I Ic::702'I i j iii I I I-0 --HEAD .-710 RM 138.3 c» lP ~ Z 70 0 i= :;706 ILl ..J ILl 704 ..". I ;po I W C7'\ B c 54.8 23.5 26,400 24,100 Figure 4-A-34.Cross sections of the head,mid-slough,mouth and access to Slough 168 depicting the water surface elevation corresponding to the slough and mainstem discharge. )\ J J J ].J ~I J j J .J I •i I J )1 ')]J 1 I 1 -J ]J 1 )1 ~ ), ::736••- HEAD RM 140.5 MOUTH RM 140.1 B "<,-- A',/ 724 MID-SLOUGH RM 140.2 20 40 60 80 CHANNEL WIDTH (feel) 8 \_ C = o 726 728-1 A I I A"c I 20 40 60 80 100 120 140 CHANNEL WIDTH (feet) z ~7~4 ~ <t > IU ~732 i 1 IU ,Ie730IiiIiIo .j::>. I )::0 I W -...J 722 J iii iiI f iiio20406080100120140160180200 CHANNEL WIDTH (feet) SLOUGH 20 OBSERVATION 0 I SCHARGE (cfs) -(WSEL)Slaugh Mainstem -,:,..:,.' --SUS/TN,q :.~~...-'-",.". /j>/V£/j>.~ I A B c 158.8 16.5 2,6 32,500 22,500 12,500 Figure 4-A-35.Cross sections of the head,mid-slough and mouth of Slough 20 depicting the water surface elevation corresponding to the slough and mainstem discharge. -SUS/TNA RIVER----+- 1';-:"!-.'.:~;.•j':.::.\~~,1::_",;":"-. :'lft'··1l=~. MOUTH RM 144.2 T7S I I Iii ii'Io50100ISO200250300350400 CHANNEL WIDTH lfeetl 7eo MID-SLOUGH RM 144.6 782 I io50 1&0 IA .......S I~:so:---=~dSLOUGH22 OBSERVATION DISCHARGE (cfsl (WSEL)Slough Moinstem A 118.5 28,200 8 31.2 27,500 C 5.1 24,100 792 '; ~ HEAD RM 144.7 784 z ~790 I- <t>W ..Jw 788 w :la: I- 786 I I I I I i I o 50 100 150 200 250 CHANNEL WIDTH lfeetl~ I :J::> I Vol CO Figure 4-A-36.Cross sections of the head,mid-slough and mouth of Slough 22 depicting the water surface elevation corresponding to the slough and mainstem discharge. )\ 1 !I J t ,J •I I J I J j I I J .1 :t ,- .... ,$/;j.11 \\'',.~,~-,.<:.'~:'''''''<:':~~:'~''''''''", ilO l1 SLOUGH SA o 1000 ,a 'Ftl.'&col:) .. "'"IE I- 570 o TA ",,,.SECT 4 STATION 3+33 22 44 68 8a CHANNEL WI011'l I f ••t) 110 -57. z 5STo 5 '"... '" i I- o TRANSICT I STATION 0+00 44 ee as 110 ,n ,54 176 CHIiNNEL WIDTH (,..u 572 TRANSECT , STATION 21"01 '70 ;::; "18"0;: ~ "'5ea;;l '""IE I- 22 ••88 '88 110 "2 CHAMMEL WIDTH (fun 571 'U TRANS£tT 5 STATION 4+22 581 517.!TRANSfer 2 z '17 STAnOH 1+11 '85z00 •;:;:....8,.~C!""'"'";;:,..w ,n '"•'"""..~IE,-5••C 581 580 0 22 ••••80 IIC ".0 ••••••86 ilO "0 CHANNEL .IDTH ih.11 CHANNEL "'IOTH (fn'~ Figure 4-A-37.Cross sections of Slough 8A at 1982 ADF&G survey transects at three discharges:A = 20 cfs.8 =7 cfs.C =4 cfs. 4-A-39 ·· ...:> 0: >- 569 565 TRANSECT 6 STATiON 4 +66 A B C 0 22 44 61 68'"0 132' CHANNE~WIDTH (101') :=572.:TRANSEC T 9 STATiON 6+0' ~570;::. c,... .J 566.... :> "..566 5114 a 22 44 ...••110 132 CHANNE~.,DTH (1011)- S74 572 TRANSECT 10 STATION 1+21 571 !·z·2 570 z 56.TRANlECT 7 .. 0 STATION 5 +29 c ;::,. c ..,..J 568..... .J H7..... "...":>..51110: >-!lIIlI lIS4 a 22 4 0 132 0 22 44 611 II 110 132 CHANNE~(1111l CKANNE~WlOTK(loo.1 573 '"'"' 572 571 TRAN5ECT II STATION 10 +OS CHANNE~WIOTH II..t) 570 ··568z 0 "'..>~566"'... :> 0:>- 564 o TRANSECT 8 STATION 6 +32 22 44 86 II CHANNE~WIDTH (III') 110 132 zo;::..,... '.J... ... :> '">- a 22 44 132 Figure 4-A-37 (Continued). 4-A-AO - -- 0,,:'" .,~ ,~. ..-SUSlrNA RIVER- EBIU SLOUGH 9 o 500 I I f.et I aP1HOll.Ica'e) Q :lZ 4"lSa SI I!la C"ANHlL lIlIIOT~Ih,,/ eoo ,.. z ,.. 0 ~a ,.. ~m TFtAJj9£CT .. 8TATn:"5 ...11I3 "".8 110 1)1 I'...111 Itl no HZ cMANHIL ",leTH U .." 'Ol~TAA,.IlCT 2"'''ON ....... m ':.\~J ~,~\~'8 '----v---,.r-', "ee al 110 IlIZ I'...118 1"no C"A""'£:L ",DT!;(1 ....IJ '"'I -,,. 0; ~ ~ . Tfitat\lliECT ill STAT 10"IS +Jo A ,8 c o U 44 •• (;""IIIfiIIIL Figure 4-A-38.Cross sections of Slough 9 at 1982 ADF&G survey transects at four discharges:A =232 cfs~B = 145 cfs,C =8 cfs,0 =3 cfs. 4-A-41 - ~I '98 44 66 88 110 1:12 1'4 CHANNEL WIOTH \1..,J 22o '96 'Tk.A.NSEC,'T 51 ~9'"!T4TION 10 +01 '90 1"3'154 n6446$88 ItO CHANNEL WIDTH (f••,~ TRANSECT T STAT ION 6+418 22o .. ::> 0:~592 132/l'2.44 66 88 110 CHANNEL WIDTH (f ..t:o '99 .. z •0 8;:: ~c 0.:'91.. ~..'89 TR4NS(C T 8 STATION 8+-33 ... z 094 0 I.. ~ OJ 592~ ~.. ~i I-~90i I l----.----r-.~-............___-~-----,o 22 44 66 88 I!O f32 CHANNEL.wID'TH "ul I Figure 4-A-38 (Conti nued).- 4-A-42 ..... 749 .TRANSECT 5.747 STATION 2 +41 ~ 0: ~745........ A..::>..743..S C 0 zz 44 68 Be 110 132 CHANNEL WIDTH t,..t) $142 _.'...~.....'::'_:..to·_. ..-SUSfTN'A 7'-...TRANSECT 3. STATION 0+00 15 747 0:~......745.. u.u~;;;:....;'.~...~..l':!'''''J7'!.!J:'.r:.~.;':'';·;;~~SLOUG H 21 o 1000 I I f •••I 0 fa IlOol.) \---------+A TRANSECT 8 STATION 2 +?3748 750 ..110ZZ446688 CHANN[L WIDTH (1011) \;::=====f!:.~ o- \--+A 2Z 4-4 66 CHANNEL WIDTH o o 22 44 B6 88 110 132 CHANNEL WIDTH (,..I) 144 749] ~TRANSECT 7 747 STATION S+82 z0;:..>..74S...... .. ::> II:743.. OJ ::>.... o 22 44 ..B8 110 CHANNEL WIDTH (,..t J 74. TRANSECT 4 747 ITATION 1+00.. z 748 5!.. ~......745.. ... ::> II:..741 f""" ! .... Figure 4-A-39.Cross sections of Slough 21 at 1982 ADF&G survey transects at three discharges:A = 157 cfs~B =10 cfs~C =5 cfs . 4-A-43 RABIOEUX CREE K o 2110.,,.., (Op".....a.oa.l ..,.,~ .~ le4 In tel TRANSECT • ,TATION 0 +00 TN"NIICT I STATION 1+114 "" .=.2" zg.... :alT....... ~c.. \+------....,...-I-A o "I 44 ·e. CItAHlln WIlITH 1I"" 110 .. ,.lel1!-+-" o j:: ~....... lei.. ~c.. lez.+----.---......--~o zz 44 II CH"NNIL WIDTH 111011 - lea II ZS41~__..,....__..,..,,,.--__ o 2~01.•• CHAIINIL WIDTH If.., I ..o j::I !.. TNMNCT T STATION 2+-'5 lao Ie. T"ANSECT e STATlON 0 +TO ~-A z0 j:: ~......... "0: 0- 253 0 zz 44 e. CHANNEL WIDTH (,..tI Figure 4-A-40.Cross sections of Rabideux Slough at 1982 ADF&G survey transects at two discharges: A =281 cfs.B =0.3 cfs. 4-A-44 ..I.UQ lIZ WIDTH If.It) T''''"IE:CT .. STATION S 1-'I' U"'''IECT I ST"'TtON &+11 n ......110111104 C:HA_L.NTH (''''1 !l ::fTll~:::::;:::;;:;;:::::;:::;;;;;;;~; CHUM CHANNEL ~I •• lapprox.acol.) ,.,.. TUMICT I ITATIO.01-00 'ni ~0'~ 11I171 TIta."IECT • ITATION t.n ~..... •••'70 'N DO MI lit •• ,n !... ! II!11'1 T".NUCT • IUTION 0.". "«••I~III II.I",..~~ CN......1.WIDTH It•••I ",ANIICT 7 ITATION '.10 1:1 44".flO 1321lJ4 CHANNEL WIDTH ('••tl 111 '70 r",,1IlIUT • ITATIDN •+.t I'44 ••..110 III 1M 17'1 C"",*L .DT"(f.t) '70 .....litO 141 84 Figure 4-A-41.Cross sections of Chum Channel at 1982 ADF&G survey transects at three discharges:A = 90 cfs~B =7 cfs~C =0.4 cfs. 4-A-45 ALASKA U.S.DEPT. l)fP'=?A.R't OF INTEr.IOR Appendix Table 4-A-1.Discharge measurements obtained in sloughs and tributaries during the open water season of 1982 from within the Susitna River basin. Discharge (cfs)Di scharge (cfs) Non Mainstem Mainstem River Geographicb Gage Instream USGS Mile a Site Code Date Time No.WSEL Flow Evaluation Sunshine 66.3 Chum Channel S22N05W13AAB 620811 1230 068.351 172.32c 47,900 Transect 1 820611 1115 4.60 47,900 Transect 2 820811 1155 6.68 47,900 Transect 3 820811 1235 9.02 47,900 Transect 4 820811 1315 6.95 47,900 Transect 5 820811 1335 6.18 47,900 Transect 6 820811 1350 6.22 47,900 Transect 7 820811 1415 7.12 47,900 Transect 8 820611 1430 4.72 47,900 68.3 Chum Channel S22N05W13AA8 820629 1530 068.3518 172.09c 34,900 Transect 1 820829 1950 0.65 34,900 Transect 2 820829 1930 0.60 34,900 Transect 3 820829 1910 0.00 34,900 Transect 4 820829 1645 0.00 34,900 Transect 5 820829 1825 0.03 34,900 ~Transect 6 820829 1805 0.04 34,900 I Transect 7 820829 1730 0.63 34,900 ):>Transect 8 820829 1630 1.04 34,900I ~ 172.80c0'\68.3 Chum Channel 522N05W13AAB 820914 1500 068.3518 53,300 Transect 1 820914 1015 63.5 53,300 Transect 2 820914 1400 86.7 53,300 Transect 3 820914 1500 91.6 53,300 . Transect 4 820914 1520 94.8 53,300 Transect 5 820914 1550 97.1 53,300 Transect 6 820914 1610 91.1 53,300 Transect 7 820914 1630 91.0 53,300 Transect 8 820914 1650 86.0 53,300 73.5 Lower Goose 2 S23N04W30BCB 820830 1540 --------10.30 78,000 Slough Above 820915 1310 73.1S4A 212.06 458.00 140,000 Creek Confluence 821001 1200 73.1S4A 210.52 1.76 31,500 73.2 Lower Goose 2 S23N04W30BCB 820830 1430 73.1S1C 209.30 101.00 76,000 5lough Below Creek Confluence aRiver mile taken from the most downstream portion of study site. bCeographic code taken from the center of the study site cRelative to temporary bench mark (TBM)which was assigned an elevation of 180.0 ft. )\ J I ]I I I J j a !J 1 J J ~ J I ~-·1 11 ).1 ·1 '1 1 J J J)) Appendix Table 4-A-l (Continued). Discharge (cfs)Discharge (cfs) Non Mainstem Mainstem River Geographicb Gage Instream USGS Mi le a Site Code Date Time No.WSEL Flow Evaluation Sunshine 73.2 Lower Goose Creek 2 S23N04W30BCB 820830 1030 73.1T2C 212.85 84.10 78,000 820915 1030 73.lT2C 213.76 251.00 140,000 821001 1015 73.1T2C 213.06 137.38 31,500 78.7 Whitefish Slough S23N05W01BBC 820916 1020 --------31.00 91,300 Tributary to Slough 78.7 Whitefish Slough SnNOSW01BBC 820831 1930 78.7W1B 238.55 22.31 48,700 Mouth 820916 1200 78.7W1A 242.54 24.20 91,300 821002 1000 78.7W1C 234.99 6.58 29,700 83.1 Rabideux Slough S24N05W16ADC 820810 1825 83.1$4A 260.00 51,600 Transect 0 820810 0.00 51,600 Transect 1 820810 0.00 51,600 Transect 2 820810 0.00 51,600 Transect 3 820810 0.00 51,600 Transect 4 820810 0.24 51,600 +:>Transect 5 820810 0.34 51,600 I Transect 6 820810 0.11 51,600 )::0 Transect 7 820810 0.49 51,600I +:> '-J 83.1 Rabideux Slough S24N05W16ADC 820917 1430 83.1S4A 263.40 88,400 Transect 0 820917 1845 853.06 88,400 Transect 3 830917 1812 167.38 88,400 Transect 4 820917 1745 166.90 88,400 Transect 5 820917 1650 170.63 88,400 Transect 6 820917 1430 156.75 88,400 Transect 7 820917 1250 171.09 88,400 83.1 Rabideux Slough S24N05W16ADC 820918 1110 83.1S4A 262.26 76,500 Transect 1 820918 1020 .83.1S4A 276.59 76,500 Transect 2 820918 1120 83.1S4A 288.60 76,500 83.1 Rabideux Slough S24N05W16ADC 821004 1530 83.1S4B 258.77 25,800 Transect 0 821004 1530 0.00 25,800 Transect 1 821004 1500 0.00 25,800 Transect 2 821004 1440 0.00 25,800 Transect 3 821004 1500 DRY 25,800 Transect 4 821004 1500 DRY 25,800 Transect 5 821004 1500 DRY 25,800 Transect 6 821004 1500 DRY 25,800 Transect 7 821004 1500 DRY 25,800 aRiver mile taken from the most downstream portion of study site. bCeographic code taken from the center of the study site. Appendix Table 4-A-1 (Continued), Appendix Table 4-A-1 (Continued). )~_.~1 J i ) J ]J J J I j I ) .j::> I )::0 I .j::> <.0 River M;le a 111.5 112.3 113.6 113.7 125.2 Site Gash Creek Slough 6A Mouth Lane Creek Lane Creek Slough Slough 8A Transect 1 Transect 2 Transect 3 Transect 4 Transect 5 Transect 6 Transect 7 Transect 8 Transect 9 Transect 10 Transect 11 Transect A Transect B Transect C Transect 1 Transect 2 Transect 3 Transect 4 Transect 5 Transect 6 Transect 7 Transect 8 Transect 9 Transect 10 Transect 11 Transect A Transect 8 ·Transect C Dhcharge (cfs)Dhcha rge (cf s ) Geographicb Non Mainstem Mainstem Gage Instream USGS Code Date Time No.WSEL Flow Evaluation Gold Creek S28N05W24ADA 820818 1150 111.5T1A 453.18 1.27 14,200 820920 1645 111.5T1A 453.69 16.60 24,000 821009 1515 111.5T1A 453.32 5.88 8,400 S28N05W13CAC 820921 1040 112.3W1B 457.61 0.63 24,200 S28N05W12ADD 820817 1424 113.6R&M 475.79 27.49 15,100 S28N05W12ADD 820903 1456 113.6528 468.28 2.05 14,600 820917 1517 113.6S2A 470.75 20.75 32,000 820920 1333 113.6528 469.41 9.92 24,000 Fishery Habitat Utilization c 530N03W30BCC 820827 12,900 820827 1130 03.21 12,900 820827 1200 04.57 12,900 820827 1225 04.03 12,900 820827 1255 04.95 12,900 820827 1400 05.49 12,900 820827 1500 03.62 12,900 820827 1530 04.52 12,900 820827 1600 02.09 12,900 820827 1620 02.79 12,900 820827 1640 03.03 12,900 820827 1705 02.49 12,900 820826 1720 09.81 13,600 820826 1636 01.48 13,600 820826 1620 01.67 13,600 820907 1630 08.52 11,700 820907 1605 09.23 11,700 820907 1545 07.93 11,700 820907 1530 06.78 11,700 820907 1456 05.63 11,700 820907 1433 06.15 11,700 820907 1405 06.81 11,700 820907 1340 05.49 11,700 820907 1314 05.98 11,700 820907 1153 06.07 11,700 820907 1127 06.58 11,700 820907 1830 04.18 11,700 820907 1723 04.98 11,700 820907 1713 02.55 11,700 aRiver mile taken from the most downstream portion of study site. bCeographic code taken from the center of the study site. c No stage measurements were obtained. Appendix Table 4-A-1 (Continued). J }J j J 1 ] ) Appendix Table 4-A-1 (Continued). j -]--1 ,J Di scha rge (cfs)Di scharge (cfs-) Geographicb Non Mainstem Mainstem River Gage Ft sHery USGS~a Site Code Date Time No.WSEL Habitat Utilization c Gold Creek 129.2 Slough 9 -Contld S30N03W16BDC Transect 1 820904 1219 09.44 14,400 Transect 2 820904 1245 07.51 14,400 Transect 3 820904 -------14,400 Transect 4 820904 1316 06.87 14,400 Transect 5 820904 -------14,400 Transect 6 820904 1433 08.43 14,400 Transect 7 820904 1452 07.57 14,400 Transect 8 820904 1518 08.47 14,400 Transect 9 820904 1543 08.73 14,400 Transect 10 820904 1605 10.34 14,400 Transect A 820904 1010 18.38 14,400 Transect B 820904 1041 17.36 14,400 Transect C 820904 1105 17.30 14,400 Transect D 820904 1134 09.58 14,400 Transect 1 820918 1550 198.30 27,500 Transect 2 820918 1510 219.90 27,500 .j::>Transect 3 820918 -------27,500 I Transect 4 820918 1430 223.40 27,500 >Transect 5 820918 -------27,500I (J1 Transect 6 820918 1340 236.30 27.500 I--'Transect 7 820918 1305 206.90 27,500 Transect 8 820918 1146 243.50 27,500 Transect 9 82091,8 1045 249.20 27,500 Transect 10 820918 0945 282.00 27,500 Transect 1 820920 1722 141.40 24,000 Transect 2 820920 1705 125.00 24,000 Transect 3 820920 -------24,000 Transect 4 820920 1633 136.70 24,000 Transect 5 820920 -------24,000 Transect 6 820920 1557 146.10 24,000 Transect 7 820920 1536 160.92 24,000 Transect 8 820920 1450 177 .40 24,000 Transect 9 820920 1359 141.10 24,000 Transect 10 820920 1255 133.10 24,000 aRiver mile taken from the most downstream portion of study site. bCeographic code taken from the center of the study site. c No stage measurements were obtained. Appendix Table 4-A-1 (Continued). Discharge (efs)Discharge (cfs) Non Mainstem Mainstem River Geograghic Cage Instream USGS~lil e a Site Code Date Time No.WSEL Flow Eval uati on Gold Creek 131.1 4th of July Creek S30N03W03DAC 820803 1200 131.1T1A 625.35 38.33 19,800 135.3 Slough 11 Above Mouth S31N02W30ABB 820830 1710 ----------5.44 13.100 135.7 Slough 11 Q Site S31N02W30ABB 820830 1244 ------670.72 3.1 13,100 820918 1010 135.3S6A 670.80 5.52 27,500 135.8 Slough 11 Above Q Site S31N02W30ABB 820830 1244 135.3S5A 675.42 1.30 13,100 138.0 Slough 16B Below Q Site S31N02W17ABD 820902 1212 ------..---0.94 16,000 820914 1718 138.0\tl1C 697.38.1.79 20,200 138.0 Slough 16B Q Site S31N02W17ABD 820801 1551 138.0S58 700.85 54.80 26,400 820915 1412 138.OSSA 701.70 257.64 28,200 820919 1617 138.0S58 700.58 23.50 24,100 140.0 Slough 19 S31 N02W1 ODBD 820819 1730 140.0W18 718.79 0.40 13,300 .f:::>140.2 Slough 20 S31N02W10ADB 820820 1120 140.1S58 726.76 2.60 12,500I )::0 820901 1643 140.1S5B 726.89 11.57 17.900Ic.n 820916 1415 140.1S58 728.06 158.80 32,500 N 820918 1825 140.1S58 727.27 44.82 27.500 820802 1220 140.1S5B 726.99 16.45 22,500 140.6 Slough 20 Tributary at S31N02W10AD8 820901 1545 140.1T3B 730.22 0.73 17,900 Head 820916 1232 140.1T3B 731.40 23.45 32,500 820918 1717 140.1T3B 730.74 9.28 27,500 aRiver mile taken from the most downstream portion of study site. bCeographic code taken from the center of the study site. )) 1 I ,I )I !J J ]I J J J J J J ) J J 1 J J -I J I j 1 r J J )] J Appendix Table 4-A-1 (Continued). Discharge (cfs)Di scharge (cfs) Non Mainstem Mainstem River Ceograghic Gage Fishery USGS Mile a Site Code Date Time No.WSEL Habitat Utilizationc Cold Creek 141.8 Slough 21 S31N11W02AM 820902 16,000 Transect 1 820902 1818 6.34 16,000 Transect 2 820902 1750 6.49 16,000 Transect 3 820902 1720 6.14 16,000 Transect 4 820902 1705 5.57 16,000 Transect 5 820902 1650 4.86 16,000 Transect 6 820902 1635 4.39 16,000 Transect 7 820902 1622 4.74 16,000 Transect 8 820902 1540 7.78 16,000 Transect 1 820917 1140 538.00 32,000 Transect 2 820917 1510 513.51 32,000 Transect 3 820917 1712 170.15 32,000 Transect 4 820917 1800 161.93 32,000 Transect 5 820917 1836 154.54 32,000 Transect 6 820917 1900 152.36 32,000 Transect 7 820917 1925 145.07 32,000 -l=:>Transect 8 820917 --------32,000 I>Transect 1 820919 1100 10.50 24,100 I U1 Transect 2 820919 1140 10.69 24,100 w Transect 3 820919 1100 10.53 24,100 Transect 4 820919 1136 9.31 24,100 Transect 5 820919 1215 9.27 24,100 Transect 6 820919 1240 11.19 24,100 Transect 7 820919 1235 19.23 24,100 Transect 8 820919 1300 0.19 24,100 aRiver mile taken from the most downstream portion of study site. bCeographic code taken from the center of the study site. c No stage measurements were obtained. .j:::> I ;J::- I U1 .j:::> Appendix Table 4-A-l (Continued). Discharge (cfs)Di scharge ·(cfs) Non ~1ai nstem Mainstem River GeograBhic Gage Instream USGS Mi 1e a 5ite Code Date Time No.WSEL Flow Evaluation Gold Creek 141.9 5lough 21 Q 5ite 531 N02W02AAA 820802 1400 142.0568 744.93 5.03 22,500 820831 1518 142.056B 744.90 3.25 16,000 820916 1024 ..142.0S6B 746.52 59.24 32,500 144.4 Slough 22 ADF&G Q 5ite S32N01W32BBC 820802 1600 144.355B 783.52 2.47 22,500 820831 1141 144.3S5B 783.60 1.64 16,000 144.6 Slough 22 532N01W32BBC 820915 1642 144.356B 785.08 118.52 28,200 820918 1425 144.356C 784.28 31.22 27,500 820919 1124 144.3566 783.84 5.11 24,100 aRiver mile taken from the most downstream portion of study site. bGeographic code taken from the center of the study site • l \ !J .. .J ]J J ])I •J I I ~J .1 I J ~, );:l I CJ1 CJ1 -J -I ~~!1 J I J )I j J J J 1 1)) Appendix Table 4-A-1 (Continued). Discharge (cfs)Discharge (cfs) Non Mainstem Mainstem River GeograBhic Cage USGS Mile a Site Code Date Time No.WSEL Impoundment C V Canyon 176.7 Fog Creek S31N04E16DBB 820815 269 11,800 820912 307 7,830 181.3 Tsusena Creek S32N04E36ADB 820816 330 12.200 820912 363 7,830 186.7 Deadman Creek S32N05E26CDB 820821 228 9,220 194.1 Watana Creek S32N06E25CCA 820815 229 11,800 820919 557 12,400 208.5 Jay Creek S31N05E13BCC 820812 61 9,990 820919 154 12,400 231.3 Goose Creek S30N11E32DBC 820819 79 9,580 820916 150 18,800 aRiver mile taken from the most downstream portion of study site. bGeographic code taken from the center of the study site. eNo stage measurements were obtained. Appendix Table4-A-2 Comparison of mainstem water surface elevations to mean daily mainstem discharge (CFS),obtained at the USGS gaging station at Gold Creek. ...,. I ;t:. I U'l 0'\ Location Left Bank at LRX-6 (R.M.101.0) Mainstem at Whiskers Creek Slough (R.M.101.2) Talkeetna Fish Wheel Camp (R.M.103.0) ----Data not available. Date Time WSEL (ft)Discharge (CFS) 821009 1245 360.36 8,440 820909 1700 361.40 13,400 820904 1330 362.13 14,400 820920 1500 363.72 24,000 821012 1633 362.73 7,950 821009 1030 362.89 8,440 821007 1415 362.96 8,640 820822 1630 363.44 12,200 820823 1124 363.47 12,300 820924 1720 363.65 12,900 820909 1250 363.64 13,400 820813 1420 363.70 13,600 810927 1825 363.83 13,800 820903 1545 363.97 14,600 820831 ----364.07 16,000 820807 1347 364.13 16,500 820808 1950 364.22 16,600 820920 1450 365.39 24,000 820715 1110 365.38 25,600 821012 1150 374.90 6,900 821011 1325 374.97 6,900 821010 1310 375.06 7,050 821009 1350 375.04 8,440 821008 1300 375.07 7,170 821006 1305 375.26 7,500 820908 1535 375.99 11,900 820822 1000 375.98 12,200 820821 1415 376.05 12,200 820829 1000 376.00 12,200 820823 1000 376.02 12,300 820828 1725 376.10 12,400 820929 1345 376.12 12,400 820930 0830 376.09 12,500 820820 1100 376.12 12,500 820928 1410 376.27 12,900 820827 1715 376.24 12,900 820912 1420 376.33 13,200 820909 1440 376.32 13,400 820911 1530 376.39 13,600 820905 2030 376.43 13,600 820814 1505 376.39 13,600 820927 1610 376.47 13,800 J J ) 8 ~J )J .J ) ) ~ J t ,I J J !]I J J -)·-E 1 I J 1 ) »'I s ) 1 Appendix Table 4-A-2 (Continued). Location Date Time WSEL (ft)Discharge 1CFS) Talkeetna Fish Wheel Camp -Cont'd 820910 1440 376.60 14,400 (R.M.103.0)820812 2000 376.61 14,400 820815 1300 376.58 14,800 820925 1410 376.76 15,000 820913 1520 376.72 15,200 820816 0930 376.80 15,600 820707 1715 376.86 16,600 820924 1530 377.13 17,100 820923 1800 377.53 19,400 820914 1510 377.75 20,200 820721 2400 377.92 21,900 820922 1255 378.20 22,300 820802 1425 378.21 22,500 820729 1630 378.31 23,600 820920 1610 378.51 24,000 820921 1340 378.41 24,200 820719 0715 378.42 24,900 820718 2300 378.43 25,400 820716 1300 378.42 25,600a (26,500,b8206232130378.67 26,000 820801 1645 378.76 26,400 +:=0 820730 1320 378.90 26,400 I 820724 1345 378.87 26,800 ~820625 2200 378.99 27,000I <..T1 820714 0745 378.81 27,300 ~820918 1217 379.02 27,500 820626 1535 379.24 28,Oooa (28,500)b 820731 1100 379.24 28,400 820127 1535 379.24 29,100a (29,00Olb8206281600379.40 30,000 820726 1430 379.88 31,800 820725 1255 379.95 31,900 820916 1445 380.01 32,500 Right Bank at LRX-9 821012 1631 377 .42 7,950 (R.M.103.2)821010 1000 377.70 8,480 820909 1700 379.10 13,400 820903 1630 379.49 14,600 820831 ----379.60 16,000 Side Channel at Gash Creek 821009 1500 448.54 8,440 (R.M.111.5)821004 1505 448.79 10,500 820818 1328 449.09 14,200 820920 1710 449.92 24,000 820921 1240 449.75 24,200 ----Data not available. a Gold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. bAmended mainstem discharge at Gold Creek as determined from ADFG stage-discharge curve.Not used in plotting stage-discuarge curve. Appendix Table 4-A-2 (Continued). J J -,J J »1 '.J J ....i J J )1 1 .1 1 .~)) Appendix Table 4-A-2 (Continued). .p- I )::0 I (J1 l.O location Curry Fish Wheel Camp -Cont'd (R.M.120.6) Right Bank at LRX-24 {R.M.120.7} Date Time WSEl eft) 820803 1900 522.65 19,800 820914 2000 522.85 20,200 820709 1000 522.73 21,500 820721 1930 522.89 21,900 820722 2130 523.01 22,400 820702 1200 523.14 22,800 820710 1800 523.11 23,000 820729 1500 523.31 23,600 820711 ----523.13 24,000 820920 1239 523.40 24,000 820719 2000 523.23 24,900 820701 1130 523.34 25,000 820717 1800 523.43 25,300 820718 1830 523.54 25,400 820728 1530 523.53 25,600 820716 '2000 523.39 25,600 820715 0900 523.66 25,600 820624 1500 523.64 26,000a 820623 1030 523.63 26,OOOa 820801 2100 523.42 26,400 820712 1600 523.57 26,500 820724 2200 523.59 26,800 820625 1300 523.77 27000a 820630 1100 523.57 27:000a 820714 1500 523.72 27,300a8206261030523.98 28,000 820731 1100 524.00 28,400a8206271200523.94 29,000 820629 1100 524.05 29,OOOa 820727 1800 524.14 29,100a8206282230524.19 30,000 820726 1300 524.46 31,800 820725 1800 524.49 31,900 820916 2000 524.56 32,500 821012 1617 520.88 7,950 821008 1300 521.04 8,480 821004 1139 521.60 10,500 820907 1000 521.70 11,700 820908 0930 521.72 11,900 820829 1500 521.82 12,200 820906 1800 521.82 12,200 820930 1652 522.06 12,500 820830 1330 522.01 13,100 820912 .1030 522.06 13,200 Discharge (CFS) b{26,500)b (26,500) {25,500)b (28,000)b {28,500}b (29,OOO)b ~---Data not available. aGold Creek stream gage malfunctioned,USGS estimated valve.Not used in plotting stage-discharge curve. bADFG estimated flow at Gold Creek based on stage-discharge curve.Not used in plotting stage-discharge curve. Appendix Table 4-A-2 (Continued). Location Date Time WSEL (ft)Di scha rge (CFS) Right Bank at LRX-24 -Contld 820909 1645 522.08 13,400 (R.M.120.7)820911 1030 522.12 13,600 820910 0945 522.22 14,400 820903 1350 522.35 14,600 820913 1220 522.49 15,200 820831 1230 522.58 16,000 820914 1600 523.18 18,200 .820919 1226 524.05 24,100 Right Bank at LRX-28 821008 1000 552.39 8,480 (R.M.124.4)821004 1129 553.14 10,500 820930 1352 553.80 12,500 820909 1645 554.17 13,400 820903 1233 554.47 14,600 820902 1836 554.61 16,000 820919 1201 556.77 24,100 Right Bank at LRX-29 821012 1608 568.41 7,950 (R.M.126.1)821004 1123 569.51 10,500 821001 1100 570.02 12,400 820909 1640 570.41 13,400 +:>820831 ----570.91 16,000 I 820920 1131 572.18 24,000 :t:> I Right Bank at LRX-31 821012 1605 595.05 7,950Q) 0 (R.t-I.128.7)821004 1117 595.95 10,500 821001 1259 596.39 12,400 820909 1640 596.92 14,400 820903 1220 597.15 14,600 820902 1619 597.29 16,000 820831 ----597.22 16,000 820919 1103 598.38 24,100 Right Bank at LRX-35 821012 1603 615.95 7,950 (R.M.130.9)821004 1107 617.14 10,500 821001 1406 617.58 12,400 820909 1630 618.05 13,400 820903 1210 618.28 14,600 820902 1518 618.47 16,000 820831 ----618.55 16,000 820919 1040 619.86 24,100 820915 1047 620.66 28,200 820917 1016 621.08 32,000 Mainstem at 4th of July Creek 821012 1603 615.17 7,950 (R.M.131.1)820907 1750 615.64 11,700 ----Data not available. )~~J I J ]J I I J J I .m I i I }J J J -1 )1 1 -1 I t ) .I Appendix Table 4-A-2 (Continued). Location Date Time WSEL (ft)Di scha rge (CFS)--- Mainstem at 4th of July Creek -820822 1340 615.63 12,200 Contld 820813 1235 615.69 13,600 (R.M.131.1)820818 1735 615.74 14,200 820902 1705 616.01 16,000 820915 1100 618.19 28,200 820917 1104 618.72 32,000 Left Bank at LRX-40 821012 1601 655.44 7,950 (R.M.134.3)821004 1059 655.83 10,500 821001 1631 655.99 12,400 820909 1430 656.24 13,400 820902 1452 656.47 16,000 820831 ----656.49 16,000 820914 1815 657.12 20,200 820919 1006 657.60 24;100 820915 1119 658.37 28,200 820917 1005 658.67 32,000 Side Channel below mouth of 821012 1555 665.56 7,950 Slough 11 821002 1040 666.68 11,700 (R.M.135.3)820906 1600 666.66 12,200 ~820929 1830 666.81 12,400 I 820830 1740 667.46 13,100 ):.-820909 1420 667.36 13,400, 0"1 820831 ----668.16 16,000 I-' Side Channel above mouth of 821012 1555 667.50 7,950 Slough 11 820907 1820 668.10 11,700 (R.M.135.3)820822 1535 667.92 12,200 820830 1735 668.62 13,100 820909 1420 668.55 13,400 820831 ----668.80 16,OOOa 820728 2030 669.44 25,600 b8206241020669.75 26,000 (26,500)b 820622 1050 670.15 26,000a (31,500) 820714 1210 669.67 27,300 (37,OOO)b8206211045670.64 28,OOOa Mainstem at Mouth of Slough 16B 821012 1551 694.22 7,950 (R.M.137.9)821002 1425 695.62 11,700 820822 1440 696.06 12,200 820909 1420 696.49 13,400 820813 1105 696.53 13,600 820902 1115 697.05 16,000 820914 1656 698.04 20,200 --~-Data not available. aGold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. bAmended mainstem discharge at Gold Creek as determined from ADFC stage-discharge curve.Not used in plotting stage-discharge curve. Appendix Table 4-A-2 (Continued). Location Date Time WSEL (ft)Discha rge (CFS) Mainstem at Mouth of Slough 16B -820920 1340 698.69 24,000 Cont'd 820919 1705 698.72 24,100 (R.M.137.9)820723 1000 698.74 24,900 820915 1259 699.93 28,200 820726 1230 700.00 31,800 820725 1105 700.05 31,900 Mainstem at Head of Slough 16B 820909 1420 701.98 13,400 (R.M.138.3)820813 1020 702.02 13,600 820831 1900 702.55 16,000 820914 1623 703.32 20,200 820920 1330 703.76 24,000 820919 1540 703.73 24,100 820915 1249 704,72 28,200 820725 1120 704.78 31,900 Left Bank at LRX-50 821012 1550 701.95 7,950 (R.M.138.5)821003 1743 702.86 11,000 821002 1620 703.01 11,700 820904 1415 703.97 14,400 820902 1210 704.39 16,000 ~820901 1906 704.88 17,900 I 820914 1515 705.22 20,200 ):0 820919 1531 705.57 24,100I O'l 820918 1912 705.82 27,500 N Left Bank at LRX-51 821012 1549 707.00 7,950 (R.M.138.9)821003 1742 707.68 11,000 821002 ----707.72 11,700 820909 1415 708.34 13,400 820902 1205 708.73 16,000 820914 1512 709.47 20,200 820919 1530 710.07 24,100 Mainstem at Slough 19 821012 1548 719.13 7,950 (R.M.139.8)821003 1740 719.91 11,000 820822 1400 720.33 12,200 820820 0910 720.31 12,500 820819 1020 720.43 13,300 820819 1734 720.47 13,300 820909 1330 720.59 13,400 820905 1530 720.52 13,600 820831 1825 721.00 16,000 820807 1000 721.03 16,500 820806 1505 721.08 16,800 820901 1747 721.23 17,900 ----Data not available. •J J )'~ »J I I )I I I a J J i J , ~~l -~~ Appendix Table 4-A-2 (Continued). )1 J 1 1 1 I 1 '1 .'1 J)) Location Date Time WSEL (ft)Di scha rge (CFS) Mainstem at Slough 19 -Cont'd 820708 1315 721.21 18,100 (R.M.139.8)820914 1502 721.45 20,200 820711 1930 721.98 24,000 820919 1525 721.75 24.100a b8206221110722.75 26.000 (31,500)b 820623 0940 722.20 26.000a (26.500) 820801 1706 721.96 26,400a b8206201920723.08 28,000 (33,250)b 820621 ----723.24 28,000a (37.000) 820727 1310 722.44 29.100 820726 1245 722.61 31,800 820725 1140 722.67 31.900 820916 1530 722.92 32,500 Right Bank at LRX-53 821012 1547 722.34 7,950 (R.M.140.1)821010 1300 722.62 8.480 821003 1621 723.19 11,000 820822 1335 723.62 12,200 820821 0930 723.53 12,200 820820 1905 723.62 12,500 ~820819 1945 723.70 13,300 I 820813 0930 723.97 13,600:::-820926 1215 723.96 14,000I 0"\820831 1820 724.39 16,000w8208071045724.51 16.500 820901 1500 724.76 17.900 820708 1500 724.73 18.100 820804 1430 724.80 18,500 820914 1412 724.98 20,200 820802 1305 725.41 22,500 820920 1248 725.52 24,000 820919 1514 725.52 24,100a b820619----726.23 25,000 (28,500)b 820623 0940 725.96 26,000a (26,500)b 820622 1115 726.66 26.000a (31,500) 820801 1803 725.69 26,400 820714 1200 725.71 27.300 820918 1806 725.78 27,500 820915 1532 726.55 28,200 820727 1150 726.32 29,100 820725 1700 726.31 31,900 Mainstem at Head of Slough 20 821012 1546 729.99 7,950 (R.M.140.6)821003 1540 730.39 11,000 ----Data not available. aCold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. bAmended mainstem discharge at Gold Creek as determined from ADFG stage-discharge curve.Not used in plotting stage-discharge curve. Appendix Table 4-A-2 (Continued). -<)j <') '---'1 J ,-<' ) J •<<]-)1 ) 1 -.. j Appendix Table 4-A-2 (Continued). Location Date Time WSEL{ft)Discharge (CFS) Mainstem at Slough 22 -Cont'd 820909 1330 786.60 13 ,400 (R.M.144.7)820813 0855 786.69 13,600 820831 1115 787.07 16,000 820807 1215 787.27 16,500 820901 1240 787.52 17 ,900 820708 1800 787.69 18,100 820914 1129 787.78 20,200 820802 1720 788.06 22,500 820720 1100 788.39 22,900 820920 1125 788.40 24,000 820919 1038 788.37 24,100 820728 1135 788.82 25,600 820623 1735 788.90 26,000 820622 1615 789.48 26,000 820918 1547 788.76 27,500 820918 1400 788.85 27,500 820726 1315 789.57 31,800 Left Bank at LRX-61 821012 1535 Dry 7,950 (R.M.148.7)820909 1325 834.25 13,400 820904 1800 834.45 14,400 .,t:::.820709 ----836.09 21,500 I 820710 1600 836.20 23,000 ::t:o 820726 1500 837.00 31,800I 0"1 (J1 Left Bank at LRX-62 821012 1532 Dry 7,950 (R.M.148.9)820909 1325 836.53 13,400 820909-----836.45 13,400 820904 1800 836.68 14,400 820709 ----838.39 21,500 820919 1800 838.79 24,100 ----Data not available. Appendix Table 4-A-3.Comparison of periodic water surface elevations ~ (WSEL)at selected sloughs upstream of Talkeetna to the corresRonding average daily mainstem discharge at pIli'''' Gold Creek.- Part A:Upland Sloughs b -WSEL Discharge Location Date Time (ft)(cfs) Mouth of Slough 6A 821009 1600 455.13 8,440 -Gage Site 112.3W1 820822 1645 455.92 12,200 (R.M.112.3)820820 1725 456.02 12,500 820926 1405 456.41 14,000 ~ 820910 1330 456.40 14,400 820925 1740 456.53 15,000 820807 1200 456.58 16,500 820808 1720 456.68 16,600 - 820709 1850 457.20 21,500 820729 1445 457.46 23,600 820921 1000 457.63 24,200 .~ 820917 1717 458.33 32,000 Mouth of Slough 19 821002 1733 718.61 11,700 Gage Site 140.0W1 820820 0925 718.76 12,500 (R.M.139.8)820819 1050 718.73 13,300 820813 1015 718.85 13,600 820905 1515 718.76 13,600 820925 1150 719.02 15,000 820831 1832 719.43 16,000 820807 1000 719.69 16,500 .... 820806 1510 719.83 .16,800 820708 1300 720.16 18,100 820914 1507 720.60 .20 ~200c d ~ 820622 1110 721.28 26,000 (31,500)d 820623 0940 721.79 26,000c (26,500) 820801 1656 722.20 26,400 c d8206201910722.18 28,000c (33,250)d 820620 1110 722.30 28,000 (33,250) 820915 1550 721.97 28,200 820727 1315 721.55 29,100 820726 1245 721.88 31,800 a USGS provisional data,1982.-bThe upstream end (head)of an upland slough is not normally connected to the mainstem Susitna River or its side channels during higher flows. c Gold Creek stream gage malfunctioned,USGS estimated value.""'l dAmended mainstem discharge at Gold Creek as determined from AOFG stage- discharge curve. 4-A-66 -,-Appendix Table 4-A-3 (Continued) .... Part B:Side Sloughs a ,-WSEL Discharge Location Date Time (ft)(cfs) Mouth of Whiskers Creek Slough 821009 1030 362.92 8,440.r-Gage Site 101.2W1 820823 1126 363.44 12,300 (R.M.101.2)820928 1715 363.64 12,900 820909 1500 363.67 13,400-,820927 1605 363.85 13,800 820903 1550 363.97 14,600 820816 1715 364.03 15,600 820709 1715 364.77 21,500 820710 1030 365.84 23,000 820920 1515 365.38 24,000b 820611 365.86 24,000 820621 1300 366.75 28,000b {37,000)c 820726 1720 366.38 31,800 820725 1100 366.88 31,900 Mid-Slough at Whiskers Creek 821009 1145 365.58 8,440 Slough 821006 1300 365.58 8,960 .~,Gage Site 101.2S3 820908 1540 365.61 11,900 (R.M.101.4)820822 1353 365.56 12,200 820928 1705 365.64 12,900 820813 1355 365.61 13 ,600 ~820927 1550 365.68 13,800 820903 1550 365.65 14,600 820816 1445 ,365.81 15,600 i~820920 1530 366.20 24,000b 820611 366.64 24,000 820715 1300 366.16 25,600 820622 0935 367.22 26,000~(31,500)c 820621 1300 367.61 28,000 (37,00O)c Head of Whiskers Creek Slough 820904 1300 Dryd 14,400 ~Gage Site 101.2H5 820903 1550 Dryd 14,600 (R.M.101.6)820816 1445 Dryd 15,600 820920 1830 368.09 24,000-820715 1415 368.18 25,600 820725 1040 368.89 31,900 - aThe mainstream end (head of a side slough is usually connected to the main- stem (breached)during high flows. bGold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. cAmended mainstem discharge at Gold Creek as determined by ADFG dstage-discharge curve.Not used in plotting stage-discharge curve. Gage was dewatered,367.3 ft.was poin~of zero flow. 4-A-67 ""'" Appendix Table 4-A-3 (Continued)- ~. Part B:Side Sloughs a WSEL Discharge Location Date Time (ft)(cfs) Mid-Slough at Lane Creek Slough 821004 1235 468.24 10,500 Gage Site 113.6S2 820903 1456 468.28 14,600 (R.M.113.6)820925 1110 468.35 15,000 -820722 1010 468.80 22,400 820920 1329 469.41 24,000 820723 1010 469.15 24,900 820917 1517 470.75 32,100 ..., Head of Lane Creek Slough 820903 b 14,600DrYb Gage Site 113.6H4 820920 1310 Dry 24,000 ~ (R.M.114.1)820917 1830 474.30 32,000 Mouth of Slough 11 821002 1040 667.01 11,700 ~ Gage Site 135.3W1 820907 1825 667.15 11 ,700 (R.M.135.3)820822 1540 667.32 12,200 820906 1600 667.23 12,200 820830 1740 667.77 13,100 -820813 1115 667.81 13,600 820812 0935 667.91 14,400 820811 1825 668.04 15,400 ~-820920 1026 669.41 24,000 820728 2030 669.37 25,600 d8206221045670.16 26,000c (31,500)d .~820624 1020 669.72 26,000c (26,500) 820714 1210 669.67 27,300 820918 1026 669.71 27,500 (37,000)d8206211040670.66 28,000c .- Mid-Slough at Slough 11 821003 1513 670.77 11 ,000 Gage Site 135.3S6 821002 1100 670.76 11,700 ~, (R.M.135.7)820929 1800 670.75 12,400 820920 1300 670.80 24,000 820921 1130 670.80 24,200 820929 1800 670.75 24,400 -a The upstream end (head)of a side slough is usually connected to the main- stem Susitna River only during those high mainstem flows capable of breach- ing the head portion of the·slough. bGage was dewatered,472.9 was point of zero flow. cGold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. dAmended mainstem discharge at Gold Creek as determined from ADFG stage dis- charge curve.Not used in plotting stage-discharge curve. 4-A-68 - - P" ,(I-'~,Appendix Table 4-A-3 (Continued) '.- Part B:Side Sloughs a-WSEL Discharge Location Date Time (ft)(cfs) Head of Slough 11 820830 b 13,100DrYb Gage Site 135.3H3 820813 1140 DrYb 13,600 {R.M.136.5}820812 0935 DrYb 14,400-820811 1805 DrYb 15,400 820716 1255 DrYb 25,600 820918 1025 Dry 27,500-Mouth of Slough 16B 821002 1435 697.28 11 ,700 Gage Site 138.0Wl 820822 1445 697.18 12,200 (R.M.137.9)820813 1035 697.20 13,600 820902 1130 697.20 16,000 820919 1641 698.38 24,100 820915 1352 699.92 28,200 820725 1110 700.06 31,900 Mid-Slough at Slough 16B 821002 1454 700.08 11,700 fiilItM"r'~~\Gage Site 138.0S5 820822 1500 700.05 12,200 (R.M.138.0)820813 1040 700.07 13,600 820902 1140 700.10 16,000-820914 1722 700.18 20,200 820919 1617 700.58 24,100 820801 1551 700.85 26,400 820915 1412 701.69 28,200 Head of Slough 16B 820813 1020 Dry C 13,600 Gage Site 138.0H3 820831 1900 Dry C 16,000 (R.M•138 .3)820914 1626 703.17 20,200 820920 1310 703.55 24,000 820919 1543 703.51 24,100 820915 1252 704.50 28,200--...820725 1115 704.59 31,900 ..... aThe upstream end (head)of a side slough is usually connected to the main- stem Susitna River only during those high mainstem flows capable of breach- ing the head portion of the slough. bGage was dewatered,684.0 was the estimated point of zero flow. CGage was dewatered,703.0 ft.was point of zero flow. ""'" -, 4-A-69 4-A-70 - - ~- Appendix Table 4-A-3 (Continued) - Part B:Side Sloughs a WSEL Discharge Location Date Time (ft)(cfs) Head of Slough 20 820820 1145 b 12,500DrYb Gage Site 140.1H2 820901 1715 DrYb 17,900-(R.M.140.5)820914 1430 Dry 20,200 820709 1225 730.96 21,500 820802 1235 731.04 22,500 ~'820920 1240 731.08 24,000 820711 1800 731.26 24,000 d820619731.61 25,000c (28,500)d 820622 1145 731.43 26,000c (31,500)d ~820623 1010 731.77 26,000c (26,500) 820918 1712 731.39 27,500 820915 1539 731.76 28,200-820727 1200 731.82 29,100 820916 1220 731.95 32,500 Mouth of Slough 21 820821 1000 744.67 12,200 Gage Site 142.0W5 821001 1350 744.72 12,400 (R.M.141.8)820820 1700 744.68 12,500 820813 0925 744.70 13 ,600 820927 1645 744.75 13,800 820831 1612 744.69 16,000 820809 1335 744.72 17,000 ~820914 1315 744.70 20,200 820922 1111 744.82 22,300 820802 1400 744.82 22,500 820720 1850 744.76 22,900 820920 1225 \744.92 24,000 820919 1225 744.89 24,100 820728 1310 745.17 25,600 (26,500)d-.820623 1040 745.34 26,000c 820918 1415 745.22 27,500 820916 1134 746.59 32,500.- aThe upstream end (head)of a side slough is usually connected to the main- stem Susitna River only during those high mainstem flows capable of breach- ~ing the head portion of the slough. bGage was dewatered,730.8 ft.was point of zero flow. cGold Creek stream gage malfunctioned,USGS estimated value.Not used in,......plotting stage-discharge curve. dAmended mainstem discharge at Gold Creek as determined from ADFG stage--discharge curve.Not used in plotting stage-discharge curve. 4-A-71 aThe upstream end (head)of a side slough is usually connected to the main- stem Susitna River only during those high mainstem flows capable of breach- ing the head portion of the slough. bGage was dewatered,755.5 ft.was point of zero flow. cGold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. dAmended mains tern discharge at Gold Creek as determined from ADFG stage- discharge curve.Not used in plotting stage-discharge curve. 4-A-72 - aThe upstream end (head)of a side slough is usually connected to the main- stem Susitna River only during those high mainstem flows capable of breach- ing the slough. bGage was dewatered,787.8 ft.was point of zero flow. cGold Creek stream gage malfunctioned,USGS estimated value.Not used in plotting stage-discharge curve. dAmended mainstem discharge at Gold Creek as determined from ADFG stage- discharge curve.Not used in plotting stage-discharge curve. 4-A-74 - 4-A-75 4-A-76 ~,-Table 4-A-4.Cont. 1""", ------------------------------------------------------------- SURFACE ~GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) ___________________T -------------------------------------- 820811 1600 1.67 220 11.0 820811 1700 1.67 220 11.0 820811 1800 1.67 220 10.5 820811 1900 1.63 208 10.5 820811 2000 1.63 208 10.0 820811 2100 1.63 208 9.5-820811 2200 1.63 208 9.5 820811 2300 1.63 208 8.5 820811,2400 ,1.63 208 8.5 ?i"" 820811 DAILY MEAN 1.69 228 8.9 820812 0100 1.63 208 8.0 820812 0200 1.63 208 7.5 820812 0300 1.63 208 7.5 820812 0400,1.63 208 7.0----820812 0500 1.60 197 7.0 820812 0600 1.63 208 6.5 820812 0700 1.60 197 6.5 820812 0800 1.60 197 7.0 820812 0900 1.60 197 7.0 820812 1000 1.60 197 7.5 820812 1100 1.60 197 8.0 820812 1200 1.60 197 9.0 820812 1300 1.60 197 9.5 820812 1400 1.60 197 10.5 820812 1500 1.57 187 11.0-820812 1600 1.57 187 11.5 820812 1700 1.57 187 11.5 820812 1800 1.57 187 11.0 820812 1900 1.57 187 11.0 820812 2000 1.57 187 10.5 820812 2100 1.57 187 10.0 820812 2200 1.57 187 9.5-820812 2300 1.57 187 9.0 820812 2400 1.57 187 9.0 820812 DAILY MEAN 1.59 195 8.9 820813 0100 1.57 187 8.5 820813 0200 1.57 187 8.0 r-c 820813 0300 1.57 187 8.0 -~---------------------------------------------------------..... 4-A-77 Table 4-A-4.Cont....." ,-" ------------------------------------------------------------- SURFACE .IIiINll GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)-------------------------------------------------------------- 820813 0400 1.57 187 8.0 820813 0500 1.57 187 8.0 -820813 0600 1.57 187 7.5 820813 0700 1.57 187 7.5 820813 0800 1.53 176 7.5 -820813 0900 1.53 176 8.0 820813 1000 1.57 187 8.5 820813 ·1100 1.53 176 9.0 820813 1200 1.53 176 9.5 820813 1300 1.53 176 10.5 820813 1400 1.53 176 11.0 820813 1500 1.53 176 11.5 820813 1600 1.50 167 12.0 820813 1700 1.50 167 12.0 820813 1800 1.50 167 12.0 820813 1900 1.50 167 11.5 820813 2000 1.53 176 11.0 820813 2100 1.50 167 10.5 820813 2200 1.50 167 10.5 .~-820813 2300 1.50 167 10.0 820813 2400 1.50 167 10.0 820813 DAILY MEAN 1.53 176 9.6 .., 820814 0100 1.50 167 9.5 820814 0200 1.50 167 9.5 820814 0300 1.50 167 9.0 820814 0400 1.50 167 9.0 820814 0500 1.50 167 9.0 820814 0600 1.50 167 9.0 -820814 0700 1.50 167 9.0 820814 0800 1.50 167 9.0 820814 0900 1.50 167 8.5 820814 1000 1.50 167 8.5 820814 1100 1.50 167 8.5 820814 1200 1.50 167 8.5 820814 1300 1.50 167 9.0 -, 820814 1400 1.50 167 9.0 820814 1500 1.53 176 9.0 820814 1600 1.50 167 9.0 820814 1700 1.53 176 9.5 820814 1800 1.53 176 9.5 -------------------------------------------------------------- ,A't ~ 4-A-78 ~ ,~ -4-A-79 Table 4-A-4.Cant.~ A"<" ------------------------------------------------------------- SURFACE -GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft )(c£s)(C)----------------~-------------------------------------------- 820816 0700 1.50 167 8.0 820816 0800 1.50 167 8.0 """ 820816 0900 1.47 157 8.0 820816 1000 1.50 167 8.5 820816 1100 1.47 157 9.0 ~ 820816 1200 1.47 157 9.5 820816 1300 1.47 157 10.5 820816 1400 1.47 157 10.5 820816 1500 1.43 149 11.0 III!\FL 820816 1600 1.43 149 11.0 820816 1700 1.43 149 11.0 820816 1800 1.43 149 11.0 ~ 820816 1900 1.43 149 11.0 820816 2000 1.43 149 10.5 820816 2100 1.43 149 10.5 820816 2200 1.43 149 10.0 -820816 ·2300 1.43 149 9.5 820816 2400 1.43 149 9.5 ,...,.~ 820816 DAILY MEAN 1.46 156 9.4 820817 0100 1.43 149 9.0 820817 0200 1.43 149 9.0 820817 0300 1.43 149 9.0 820817 0400 1.47 157 8.5 820817 0500 1.47 157 8.5 -820817 0600 1.47 157 8.5 820817 0700 1.47 157 8.5 820817 0800 1.47 157 8.5 820817 0900 1.47 157 8.5 -820817 1000 1.50 167 8.5 820817 1100 1.53 176 8.5 820817 1200 1.53 176 8.5 820817 1300 1.53 176 9.0 820817 1400 1.57 187 9.0 820817 1500 1.57 187 9.0 820817 1600 1.60 197 9.5 """i 820817 1700 1.57 187 9.5 820817 1800 1.60 197 9.5 820817 1900 1.57 187 9.0 J!!\!Ol 820817 2000 1.60 197 9.0 820817 2100 1.60 197 8.5 --------------~-----------------~---------------------------.~ 4-A-80 -4-A-81 Table 4-A-4.Cont."""'" ~" ------------------------------------------------------------- SURFACE ...,. GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (it)(ds)(C)-------------------------------------------------------------- 820819 1000 1.47 157 8.0 820819 1100 1.47 157 8.5 ~, 820819 1200 1.47 157 9.0 820819 1300 1.47 157 9.5 820819 1400 1.47 157 9.5 -820819 1500 1.47 157 10.0 820819 1600 1.43 149 10.5 820819 1700 1.47 157 10.5 820819 1800 1.47 157 10.5 -, 820819 1900 1.43 149 10.0 820819 2000 1.47 157 10.0 820819 2100 1.47 157 9.5 ~ 820819 2200 1.47 157 9.5 820819 2300 1.43 149 9.0 820819 2400 1.43 149 8.5 820819 DAILY MEAN 1.47 158 8.6 820820 0100 1.43 149 8.5 ~ 820820 0200 1.43 149 8.0 820820 0300 1.43 149 8.0 820820 0400 1.43 149 7.5 820820 0500 1.43 149 7.5 ~~. 820820 0600 1.43 149 7.5 820820 0700 1.43 149 7.5 820820 0800 1.43 149 7.5 820820 0900 1.43 149 8.0 820820 1000 L43 149 8.5 820820 1100 1.43 149 9.0 820820 1200 1.43 149 9.5 820820 1300 1.40 140 10.0 820820 1400 1.43 149 11.0 820820 1500 1.40 140 11.5 820820 1600 1.40 140 11.5 820820 1700 1.40 140 11.5 820820 1800 1.40 140 11.5 820820 1900 1.40 140 11.0 820820 2000 1.40 140 11.0 820820 2100 1.40 140 10.5 820820 2200 1.40 140 10.0 820820 2300 1.40 140 9.5 820820 2400 1.40 140 9.0 ------------------------------------------------------------- 4-A-82 4-A-83 Table 4-A-4.Cont.'"'" ~" --------------------------------------------------------------SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(ds)(C)-------------------------------------------------------------- 820825 1600 1.37 132 11.0 -820825 1700 1.33 125 11.0 820825 1800 1.33 125 11.0 820825 1900 1.33 125 11.0 820825 2000 1.33 125 10.5 -820825 2100 1.33 125 10.0 820825 2200 1.37 132 10.0 820825 2300 1.37 132 10.0 820825 2400 1.33 125 9.5 - 820825 DAILY MEAN 1.36 130 9.8 820826 0100 1.37 132 9.5 820826 0200 1.37 132 9.0 820826 0300 1.37 132 9.0 820826 0400 1.37 132 9.0 820826 0500 1.37 132 8.5 820826 0600 1.37 132 8.5 820826 0700 1.37 132 8.5 .~- 820826 0800 1.37 132 8.5 820826 090~1.37 132 9.0 820826 1000 1.37 132 9.0 820826 1100 1.37 132 9.5 820826 1200 1.37 132 10.0 820826 1300 1.37 132 10.0 820826 1400 1.37 132 10.5 -820826 1500 1.37 132 11.0 820826 1600 1.37 132 11.5 820826 1700 1.37 132 11.5 820826 1800 1.33 125 11.0 820826 1900 1.33 125 11.0 820826 2000 1.37 132 10.5 820826 2100 1.37 132 10.0 820826 2200 1.33 125 9.5 820826 2300 1.37 132 9.5 820826 2400 1.33 125 9.0 -, 820826 DAILY MEAN 1.36 131 9.7 820827 0100 1.33 125 8.5 8R!: 820827 0200 1.37 132 8.0 820827 0300 1.33 125 8.0 ~------------------------------------------------------------- 4-A-86 """'l i ~ .~Table 4-A-4.Cont.-------------------------------------------------------------- SURFACE ""'"GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) ------------------------------------------------------------- 820827 0400 1.33 125 7.5 820827 0500 1.33 125 7.0 ~820827 0600 1.33 125 6.5 820827 0700 1.33 125 6.5 820827 0800 1.37 132 6.5 820827 0900 1.33 125 7.0 820827 1000 1.33 125 7.5 820827 1100 1.33 125 8.0 820827 1200 1.33 125 8.5 820827 1300 1.33 125 9.5 820827 1400 1.33 125 10.0 820827 1500 1.33 125 10.5 820827 1600 1.33 125 11.0-820827 1700 1.33 125 11.0 820827 1800 1.30 118 11.0 820827 1900 1.30 118 10.5-.-.820827 2000 1.33 125 10.5 820827 2100 1.33 125 9.5 820827 2200 1.33 125 9.5 820827 2300 1.30 118 9.0 820827 2400 1.30 118 8.5 820827 DAILY MEAN 1.33 124 8.8 820828 0100 1.33 125 8.0 820828 0200 1.33 125 8.0 820828 0300 1.33 125 7.5 820828 0400 1.33 125 7.5 820828 0500 1.33 125 7.5 820828 0600 1.30 118 7.0 820828 0700 1.33 125 7.5 820828 0800 1.33 125 7.5 820828 0900 1.33 125 7.5 820828 1000 1.33 125 8.0 820828 1100 1.33 125 8.0 820828 1200 1.33 125 8.5 820828 1300 1.33 125 8.5 820828 1400 1.33 125 9.0 820828 1500 1.33 125 9.5 820828 1600 1.33 125 10.0 820828 1700 1.30 118 10.0 ~\liIi 820828 1800 1.33 125 10.0 ------------------------------------------------------------- 4-A-87 Table 4-A-4.Cont. ------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)IIlfi'!) ------------------------------------------------------------- 820828 1900 1.30 118 10.0 820828 2000 1.30 118 10.0 ~ 820828 2100 1.33 125 9.5 820828 2200 1.33 125 9.0 820828 2300 1.30 118 9.0 ~ 820828 2400 1.33 125 9.0 820828 DAILY MEAN 1.33 123 8.6 820829 0100 1.30 118 8.5 820829 0200 1.33 125 8.5 820829 0300 1.30 118 8.5 ~; 820829 0400 1.33 125 8.5 820829 0500 1.33 125 8.0 820829 0600 1.37 132 8.0 820829 0700 1.33 125 8.0 820829 0800 1.33 125 8.0 820829 0900 1.37 132 8.0 820829 1000 1.37 132 8.0 ~.-820829 1100 1.40 140 8.5 820829 1200 1.40 140 8.5 820829 1300 1.40 140 9.0 820829 1400 1.40 140 9.0 ~, 820829 1500 1.40 140 9.5 820829 1600 1.40 140 9.5 820829 1700 1.43 149 9.5 820829 1800 1.43 149 9.5 820829 1900 1.43 149 9.0 820829 2000 1.47 157 9.0 820829 2100 1.47 157 9.0 ~ 820829 2200 1.47 157 8.5 820829 2300 1.47 157 8.5 820829 2400 1.50 167 8.5 - 820829 DAILY MEAN 1.39 139 8.6 820830 0100 1.50 167 8.5 ~I 820830 0200 1.50 167 8.5 820830 0300 1.50 167 8.5 820830 0400 1.50 167 8.0 820830 0500 1.53 176,8.0 820830 0600 1.57 187 8.0 ....,------------------------------------------------------------- 4-A-88 4-A-89 - M~Table 4-A-4.Cont. ..... ------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft )(cfs)(C) ------------------------------------------------------------- 820902 1000 1.90 320 7.0 820902 1100 1.90 320 7 .5-820902 1200 1.90 320 8.0 820902 1300 1.87 304 8.5 820902 1400 1.87 304 9.0 820902 1500 1.87 304 9.0 820902 1600 1.87 '304 9.5 820902 1700 1.83 288 9.5 820902 1800 1.83 288 9.0-820902 1900 1.83 288 9.0 820902 2000 1.83 288 9.0 820902 2100 1.83 288 8.5 820902 2200 1.80 273 8.0-820902 2300 1.83 288 8.0 820902 2400 1.83 288 8.0 F-,-',820902 DAILY MEAN 1.87 307 7.9 820903 0100 1.83 288 8.0 820903 0200 1.87 304 7.5 820903 0300 1.83 288 7.5 820903 0400 1.87 304 7.5 820903 0500 1.87 304 7.0-820903 0600 1.90 320 7.5 820903 0700 1.90 320 7.0 820903 0800 1.90 320 7.0 820903 0900 1.93 337 7.0 820903 1000 1.93 337 7.0 820903 1100 1.93 337 7.0 820903 1200 1.97 355 7 .5 820903 1300 1.93 337 7 .5 820903 1400 1.93 337 8.0 820903 1500 1.93 337 8.5iG__ 820903 1600 1.93 337 8.5 820903 1700 1.93 337 8.5 820903 1800 1.90 320 8.5 820903 1900 1.90 320 8.5 820903 2000 1.90 320 8.0 820903 2100 1.90 320 8.0 820903 2200 1.90 320 7 .5,-820903 2300 1.90 320 7 .5 820903 2400 1.87 304 7.0 ~------------------------------------------------------------- -4-A-91 Table 4-A-4.Cant.~,-'------------------------------------------------------------- SURFACE ~ GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(ds)(C) ------------------------------------------------------------- ~820903 DAILY MEAN 1.90 322 7.6 820904 0100 1.90 320 7.0 820904 0200 1.90 320 7.0 -820904 0300 1.90 320 7.0 820904 0400 1.90 320 7.0 820904 0500 1.87 304 6.5 ~ 820904 0600 1.87 304 6.5 820904 0700 1.87 304 6.5 820904 0800 1.83 288 6.5 304 7.0 ....820904 0900 1.87 820904 1000 1.83 288 7.0 820904 1100 1.83 288 7.5 820904 1200 1.83 288 8.0 820904 1300 1.83 288 8.0 820904 1400 1.80 273 8.5 820904 1500 1.80 273 9.0 -820904 1600 1.80 273 9.0 820904 1700 1.77 259 9.0 820904 1800 1.80 273 9.0 820904 t900 1.80 273 8.5 -820904 2000 1.80 273 8.5 820904 2100 1.80 273 8.0 820904 2200 1.80 273 7.5 ~ 820904 2300 1.80 273 7.5 820904 2400 1.80 273 7.0 ~I820904DAILYl-fEAN 1.83 288 7.6 820905 0100 1.77 259 7.0 820905 0'200 1.77 259 6.5 .... 820905 0300 1.80 273 6.5 820905 0400 1.80 273 6.5 820905 0500 1.80 273 6.5 """i 820905 0600 1.80 273 6.5 820905 0700 1.77 259 6.5 820905 0800 1.77 259 6.5 820905 0900 1.80 273 7.0 820905 1000 1.80 273 7 .0 820905 1100 1.77 259 7.5 820905 1200 1.77 259 7.5 ~, ------------------------------------------------------------- 4-A-92 .-4-A-93 Table 4-A-4.Cont.~ ~ ------------------------------------------------------------- SURFACE "'""GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)------------------------------------ 820907 0100 1.67 220 7.5 820907 0200 1.67 220 7.5 820907 0300 1.67 220 7.5 820907 0400 1.67 220 7.5 820907 0500 1.70 233 7.5 820907 0600 1.70 233 7.5 820907 0700 1.70 233 7.5 820907 0800 1.73 246 7.5 820907 0900 1.70 233 7.5 820907 1000 1.73 246 7.5 820907 1100 1.73 246 7.5 820907 1200 1.73 246 8.0 820907 1300 1.73 246 8.5 820907 1400 1.73 246 9.0 820907 1500 1.77 259 9.0 820907 1600 1.73 246 9.5 Moi 820907 1700 1.73 246 9.5 820907 1800 1.73 246 9.0 820907 1900 1.73 246 9.0 820907 2000 1.73 246 8.5 j~ 820907 2100 1.73 246 8.0 82Q907 2200 1.73 246 8.0 820907 2300 1.73 246 8.0 -820907 2400 1.73 246 7.5 820907 DAILY MEAN 1.72 240 8.1 820908 0100 1.70 233 7.5 820908 0200 1.70 233 7.5 820908 0300 1.73 246 7.5 ~, 820908 0400 1.70 233 7.5 820908 0500 1.70 233 7.5 820908 0600 1.70 233 7.0 820908 0700 1.70 233 7.0 QJ 820908 0800 1.70 233 7.0 820908 0900 1.70 233 7.5 820908 1000 1.67 220 7.5 ~j 820908 1100 1.70 233 7.5 820908 1200 1.67 220 7.5 820908 1300 1.70 233 8.0 820908 1400 1.67 220 7.5 ~ 820908 1500 1.70 233 8.0 ---------------------------------------------------------------- ""'!1 4-A-94 - -4-A-95 Table 4-A-4.Cant.~1 --------------------------------------------------------------- SURFACE ~, GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)~ ------------------------------------------------------------- 820910 0400 1.70 233 6.5 820910 0500 1.70 233 6.5 820910 0600 1.70 233 6.5 _820910 0700 1.67 220 6.5 820910 0800 1.70 233 6.5 820910 0900 1.70 233 6.5 820910 1000 1.70 233 6.5 820910 1100 1.67 220 7.0 820910 1200 1.67 220 7.0 ~ 820910 1300 1.67 220 7.5 820910 1400 1.67 220 8.0 820910 1500 1.67 220 8.0 --820910 1600 1.67 220 8.0 820910 1700 1.67 220 8.5 820910 1800 1.67 220 8.0 820910 1900 1.67 220 8.0 ""'1 820910 2000 1.67 220 7.5 820910 2100 1.67 220 7.5 820910 2200 1.63 208 7.0 -""'1 820910 2300 1.63 208 7.0 820910 2400 1.63 208 6.5 820910 DAILY MEAN 1.68 223 7.1 ~, 820911 0100 1.67 220 6.5 820911 0200 1.67 220 6.5 820911 0300 1.63 208 6.5 820911 0400 1.67 220 6.5 820911 0500 1.67 220 6.5 820911 0600 1.63 208 6.0 -. 820911 0700 1.67 220 6.0 820911 0800 1.63 208 6.5 820911 0900 1.67 220 6.5 """l1 820911 1000 1.63 208 6.5 820911 1100 1.67 220 6.5 820911 1200 1.70 233 6.5 820911 1300 1.70 233 7.0 """'J 820911 1400 1.73 246 7.0 820911 1500 1.73 246 7.0 820911 1600 1.77 259 7.0 -820911 1700 1.77 259 7.0 820911 1800 1.80 273 7.0 -------------------------------------------------------------~. -- 4-A:"96 r-,-Table 4-A-4.Cont. -------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIM'E (ft)(cfs)(C) ------------------------------------- 820911 1900 1.77 259 6.5 820911 2000 1.80 273 6.5 820911 2100 1.77 259 6.5 820911 2200 1.80 273 6.5 820911 2300 1.80 273 6.5 820911 2400 1.80 273 6.0 820911 DAILY MEAN 1.71 238 6.6 820912 0100 1.77 259 6.0 820912 0200 1.77 259 6.0 820912 0300 1.77 259 5.5 820912 0400 1.77 259 5.5 820912 0500 1.77 259 5.5 820912 0600 1.73 246 5.0 820912 0700 1.73 246 5.0 820912 0800 1.73 ·246 5.0 ~'~~I>.,.,820912 0900 1.73 246 5.0 820912 1000 1.73 246 5.0 820912 1100 1.70 233 5.5 820912 1200 1.70 233 6.0 820912 1300 1.70 233 6.5 820912 1400 1.70 233 7.0 820912 1500 1.70 233 7.5 820912 1600 1.70 233 7.5 820912 1700 1.70 233 7.5 820912 1800 1.70 233 7.5 820912 1900 1.67 220 7 '.5 820912 2000 1.70 233 7.0 820912 2100 1.70 233 7.0 820912 2200 1.70 233 6.5 820912 2300 1.70 233 6.5 820912 2400 1.70 233 6.5 820912 DAILY MEAN 1.72 240 6.2 820913 0100 1.73 246 6.5 820913 0200 1.77 259 6.0 820913 0300 1.77 259 6.0 820913 0400 1.80 273 6.0 820913 0500 1.83 288 6.0 820913 0600 1.90 320 6.0..... ------------------------------------------------------------ 4-A-97 J!!Im'il!',\ Table 4-A-4.Cont. ~ ,,- ------------------------------------------------------------- SURFACE .... GAGE WATER HEIGHT DISCHARGE TEMPERA TURE DATE TIME (ft )(cfs)(C) -------------------------------------------------------------~ 820913 0700 1.93 337 6.0 820913 0800 2.00 374 6.0 820913 0900 2.07 414 6.0 820913 1000 2.13 458 6.0 820913 1100 2.17 482 6.0 820913 1200 2.23 532 6.0 8209.13 1300 2.30 586 6.0 820913 1400 2.33 615 6.0. 820913 1500 2.40 677 6.5 ~- 820913 1600 2.40 677 6.5 820913 1700 2.40 677 6.5 820913 1800 2.37 645 6.5 820913 1900 2.37 645 6.5 jlllilJdl:l 820913 2000 2.37 645 6.5 820913 2100 2.37 645 6.5 820913 2200 2.33 615 6.5 820913 2300 2.37 645 6.5 820913 2400 2.37 645 6.5 820913 DAILY MEAN 2.15 473 6.2 ~- 820914 0100 2.33 615 6.5 820914 0200 2.37 645 6.5 ~ 820914 0300 2.37 645 6.5 820914 0400 2.37 645 6.5 820914 0500 2.40 677 6.5 820914 0600 2.43 .710 6.5 ~, 820914 0700 2.47 744 6.5 820914 0800 2.47 744 6.5 820914 0900 2.47 744 6.5 ~L 820914 1000 2.47 744 6.5 820914 1100 2.47 744 6.5 820914 1200 2.50 780 6.5 820914 1300 2.53 817 6.5 -~ 820914 1400 2.50 780 7.0 820914 1500 2.50 780 7.0 820914 1600 2.47 744 7.0 ,...., 820914 1700 2.47 744 6.5 820914 1800 2.50 780 7.0 820914 1900 2.53 817 6.5 820914 2000 2.53 817 6.5 -820914 2100 2.57 856 6.5 ------------------------------------------------------------- 4-A-98 ~-A-99 ~. Table 4-A-4.Cont.~-'------------------------------------------------------------- SURFACE ~, GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(ds)(C)IllI'JIlI'l1l ------------------------------------------------------------- 820916 1000 3.17 1890 6.5 820916 1100 3.13 1812 6.5 -, 820916 1200 3.13 1812 6.5 820916 1300 3.10 1737 7.0 820916 1500 3.03 1595 7.0 ~ 820916 1600 2.97 1464 7.0 820916 1700 2.97 1464 7.0 820916 1800 2.97 1464 7.0 820916 1900 2.90 1342 6.5 820916 2000,2.87 1284 6.5 820916 2100 2.87 1284 6.5 820916 2200 2.83 1229 6.0 820916 2300 2.77 1125 6.0 820916 2400 2.77 1125 6.0 820916 DAILY MEAN 3.01 1557 6.7 ~ 820917 0100 2.77 1125 6.0 820917 0200 2.77 1125 6.0 ~-, 820917 0300 2.77 1125 6.0 820917 0400 2.77 1125 5.5 820917 0500 2.80 1176 5.5 820917 0600 2.80 1176 5.5 """ 820917 0700,2.77 1125 5.5 820917 0800 2.77 1125 5.5 820917 0900 2.77 1125 5.5 820917 1000 2.77 1125 5.5 820917 1100 2.73 1075 5.5 820917 1200 2.77 1125 5.5 820917 1300 2.70 1028 6.0 820917 1400 2.70 1028 6.0 820917 1500 2.73 1075 6.0 820917 1600 2.70 1028 6.0 ~1 820917 1700 2.70 1028 6.5 820917 1800 2.67 982 6.0 820917 1900 2.63 938 6.0 820917 2000 2.63 938 6.0 """' 820917 2100 2.63 938 6.0 820917 2200 2.57 856 6.0 820917 2300 2.57 856 6.0 f~ 820917 2400 2.57 856 5.5 -------------------------------------------------------------~ 4-A-IOO -I Table 4-A-4.Cont. ~------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft )(cfs)(C) ------------------------------------------------------------ ~820917 DAILY MEAN 2.71 1041 5.8 820918 0100 2.53 817 5.5 820918 0200 2.53 817 5.5 820918 0300 2.53 .817 5.5 820918 0400 2.50 780 5.5 820918 0500 2.50 780 5.5 820918 0600 2.50 780 5.5 820918 0700 2.43 710 5.5 820918 0800 2.47 744 5.5 ~820918 0900 2.43 710 5.5 820918 1000 2.40 677 5.5 820918 1100 2.40 677 6.0 820918 1200 2.40 677 6.0 820918 1300 2.40 677 6.5 820918 1400 2.40 677 6.5 820918 1500 2.40 677 6.5 .~4~~820918 1600 2.37 645 6.5 820918 1700 2.37 645 6.5•820918 1800 2.37 645 6.5 820918 1900 2.40 677 6.5 820918 2000 2.40 677 6.5 820918 2100 2.40 677 6.5 820918 2200 2.43 710 6.5 820918 2300 2.47 744 6.0 820918 2400 2.50 780 6.0 820918 DAILY MEAN 2.44 716 6.0 820919 0100 2.53 817 6.0 820919 0200 2.53 817 6.0-820919 0300 2.53 817 6.0 820919 0400 2.53 817 6.0 820919 0500 2.57 856 6.0 820919 0600 2.53 817 6.0 820919 0700 2.50 780 6.0 820919 0800 2.53 817 6.0 820919 0900 2.50 780 6.0 820919 1000 2.53 817 6.0 820919 1I00 2.53 817 6.0 820919 1200 2.50 780 6.0 820919 1300 2.53 817 6.5 ------------------------------------------------------------- 4-A-IOI ..- I 4-A-I03 \, Table 4-A-4.Cont.~ '-'. -----------------------------------------------~-------------SURFACE """I GAGE WATER HEIGlIT DISCHARGE TEMPERA TURE DATE TIME (ft)(cfs)(C) ----------------_..._------------------- 820922 1700 2.40 677 6.0 820922 1800 2.40 677 6.0 820922 1900 2.40 677 6.0 820922 2000 2.40 677 6.0 820922 2100 2.37 645 5.5 820922 2200 2.37 645 5.5 ~ 820922 2300 2.37 645 5.0 820922 2400 2.33 615 5.0 ~ 820922 DAILY MEAN 2.42 693 5.7 820923 0100 2.37 645 5.0 820923 0200 2.33 615 4.5 ~. 820923 0300 2.30 586 4.5 820923 0400 2.33 615 4.5 820923 0500 2.30 586 4.5 -820923 0600 2.30 586 4.0 820923 0700 2.27 558 4.0 820923 0800 2.27 558 4.0 820923 0900 2.27 558 4.0 .-- 820923 .1000 2.23 532 4.0 820923 1100 2.23 532 4.0 820923 1200 2.23 532 4.5 M'IIIlI 820923 1300 2.23 532 5.0 820923 1400 2.23 532 5.5 820923 1500 2.23 532 5.5 820923 1600 2.2~532 6.0 ~ 820923 1700 2.20 506 6.0 820923 1800 2.20 506 5.5 820923 1900 2.20 506 5.5 ~ 820923 2000 2.20 506 5.0 .820923 2100 2.17 482 4.5 820923 2200 2.17 482 4.5 820923 2300 2.17 482 4.5 820923 2400 2.17 482 4.0 820923 DAILY MEAN 2.24 539 4.7 - 820924 0100 2.20 506 4.0 820924 0200 2.17 482 3.5 ~820924 0300 2.17 482 3.5 820924 0400 2.13 458 3.5 --------------~----.~---------~~-----~-----------~-----------,.... ""'"i 4-A-I04 - -- ,......"Table 4-A-4.Cont. ~-------------------------------------------------------------SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE 'TIME (ft)(cfs)(C) --------------------------------~-------------------------- 820924 0500 2.13 458 3.5 820924 0600 2.17 482 3.0 820924 0700 2.13 458 3.0 820924 0800 2.13 458 3.0 820924 0900 2.13 458 3.0 820924 1000 2.13 458 3.5 820924 1100 2.10 436 3.5 820924 1200 2.10 436 4.0 820924 1300 2.10 436 4.5 820924 1400 2.10 436 5.0 820924 1500 2.10 436 5.0 820924 1600 2.10 436 5.5 820924 1700 2.10 436 5.5 820924 1800 2.07 414 5.5 820924 1900 2.10 436 5.0 820924 2000 2.07 .414 5.0 820924 2100 2.07 414 5.0 820924 2200 2.07 414 5.0 820924 2300 2.07 414 4.5 820924 2400 2.07 414 4.5 .... 820924 DAILY MEAN 2.11 444 4.2 820925 0100 2.07 414 4.5 820925 0200 2.03 394 4.0 820925 0300 2.07 414 4.0 820925 0400 2.03 394 4.0 .-820925 0500 2.03 394 4.0 820925 0600 2.03 394 3.5 820925 0700 2.03 394 3.5 820925 0800 2.03 394 3.5-820925 0900 2.03 394 3.5 820925 1000 2.00 374 4.0 820925 1100 2.03 394 4.0 820925 1200 2.00 374 4.5 820925 1300 2.00 374 5.0 820925 1400 2.00 374 5.0 820925 1500 2.00 374 5.5 820925 1600 2.00 374 5.5 820925 1700 2.00 374 5.5 820925 1800 1.97 355 5.5 820925 1900 1.97 355 5.5 ------------------------------------------------------------- 4-A-I05 4-A-I06 - 4-A-I07 ...... ""'" 't~,Tab Ie 4-A-4.Cont. /"'"-------------------------------------------------------------SURFACE GAGE WATER I"""HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) -------------------------------- 820930 1100 1.93 337 5.0 820930 1200 1.90 320 5.0 820930 1300 1.93 337 5.5 820930 1400 1.90 320 5.5 820930 1500 1.90 320 6.0 820930 1600 1.90 320 6.0 820930 1700 1.90 320 6.0 820930 1800 1.90 320 5.5 820930 1900 1.90 320 5.5 820930 2000 1.90 320 5.5 i 820930 2100 1.90 320 5.5 820930 2200 1.90 320 5.0 820930 2300 1.90 320 5.0 .....820930 2400 1.87 304 5.0 820930 DAILY MEAN 1.92 ,330 5.1-.-821001 0100 1.87 281 4.5 821001 0200 1.87 281 4.5 821001 0300 1.87 281 4.5 r""821001 0400 1.87 281 4.5 821001 0500 1.87 281 4.5 821001 0600 1.87 281 4.5 821001 0700 1.87 281 4.5 821001 0800 1.87 281 4.0 821001 0900 1.87 281 4.5 821001 1000 1.87 281 4.5 821001 1100 1.87 281 4.5 821001 1200 1.87 281 4.5 821001 1300 1.87 281 5.0 821001 1400 1.87 281 5.0 821001 1500 1.87 281 5.0 821001 1600 1.87 281 5.0 821001 1700 1.83 266 5.0 821001 1800 1.87 281 5.0 821001 1900 1.87 281 5.0 . 821001 2000 1.83 266 4.5 821001 2100 1.83 266 4.5 821001 2200 1.83 266 4.5 821001 2300 1.83 266 4.5 821001 2400 1.83 266 4.5 ..... ------------------------------------------------------------ 4-A-I09 4-A-llO' !"'" 4-A-ll1 4-A-112 4-A-113 Table 4-A-4.Cont. """ ,...."--------_..-----------._---------------~-.-------SURFACE GAGE WATER HEIGltT DISCHARGE TEM'pEkA'tURE DATE TIME (ft)(cfs)(C) --------.-........-----....--_..__________________...__~........'___IIIIIiII,..".._ 821008 0500 1.60 181 2.0 821008 0600 1.60 181 2.0 821008 0700 1.57 171 2.0 821008 0800 1.60 181 2.0 821008 0900 1.51 171 2.0 821008 1000 1.57 171 2.0 821008 1100 1057 171 2.5 821008 1200 1 ..57 171 2.5 821008 1300 1.57 171 2.5 -821008 1400 1.57 171 3.0 821008 1500 1.57 111 3.0 821008 1600 1.57 171 3.0 821008 1700 1.57 171 3.0 ~ 821008 1800 1.57 171 3.0 821008 1900 1.57 171 3"D 821008 2000 1..5'7 171 2.5 -821008 2100 1.57 171 2..5 821008 2200 1.57 171 2.5 821008 2300 1 ..57 171 2 ..0 821008 2400 1.57 171 2.'0 ~.~ 821008 DAILY MEAN 1.58 174 1.4 821009 0100 1.57 171 2.0 821009 0200 1.57 171 2.'0 821009 0300 1 ..57 111 2.0 821009 0400 1.57 171 2.0 -821009 0500 1 ..57 171 2.0 821009 0600 1.57 171 2.0 821009 0700 1.57 171 2.0 821009 0800 1.57 171 2 ..0 821009 0900 1.'57 171 2.0 821009 1000 1.57 171 2.0 821009 1100 1.57 171 2.5 821009 1200 1.57 171 3.0 821009 1300 1.57 171 3.0 821009 1400 1.57 171 3.0 821009 isoo 1.57 171 3.5 821009 1600 1.57 171 3.5 821009 1700 1.57 171 3.5 821009 1800 1.57 171 3.'0 -821009 1900 1.57 171 3.0 4-A-114 - 4-A-115 Table 4-A-4.Cont. ~----------....---...-------..---------..---..--------..-.-... SURFACE -GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)~------ry,-----'..-~..------.j'---...-.- 821011 0800 1.50 153 2.0 821011 0900 1.53 162 2.0 ~ 821011 1000 1.50 153 2.0 821011 1100 1.50 153 2.0 821011 1200 1.50 153 2.5 821011 1300 1.50 153 2.5 -821011 1400 1.50 153 2.5 821011 1500 1.50 153 2.5 821011 1600 1.50 153 2.5 821011 1700 1.50 153 2.5 821011 1800 1.50 153 2.0 821011 1900 1.50 153 2.0 821011 2000 1.50 153 2.0 821011 2100 1.50 153 2.0 821011 2200 1.50 153 2.0 .821011 2300 1.50 153 2.0 -821011 2400 1.50 153 1.5 821011 DAILY MEAN 1.50 154 2:.1 ~.- 821012 0100 1.53 162 1.5 821012 0200 1.53 '162 1.5 821012 0300 1.53 162 1.0 -821012 0400 1.53 162 1 •.0 821012 0500 1.53.162 1.5 821012 0600 1.53 162 1.5 821012 0700 1.53 162 1.5 821012 0800 1.53 162 1.5 821012 0900 1.53 162 1.5 821012 1000 1.53 162 2.0 821012 1100 1.50 153 2.0 821012 1200 1•.53 162 2.0 821012 1300 1.53 162 2.0 ~821012 1400 1.50 153 2.5 821012 1500 1.50 153 2.5 821012 1600 1.50 153 2.5 821012 1700 1.53 162 2.5 -821012 1800 1.53 .162 2.5 821012 1900 1.53 162 2.5 821012 2000 1.53 162 2.5 821012 2100 1.57 171 2.5 821012 2200 1.57 171 2.5 --------~-~-------~~--~--------~--------.-----.-.,. ~'\\ 4-A-116 """-Table 4~A-4.Cont. -------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) -----------------_.------------------------------------------ 821012 2300 1.57 171 2.5 821012 2400 1.60 181 2.5 821012 DAILY MEAN 1.53 162 2.0 821013 0100 1.57 171 2.0 821013 0200 1.57 171 2.0 821013 0300 1.57 171 2.0 821013 0400 1.57 171 1.5 821013 0500 1.57 171 1.5-821013 0600 1.53 162 1.5 821013 0700 1.53 162 1.5 821013 0800 1.53 162 1.5 821013 0900 1.53 162 1.5 821013 1000 1·.53 162 1.5 821013 1100 1.53 162 1.5 821013 1200 1.53 162 1.5 mm;!I,~\821013 1300 1.53 162 1.5 821013 1400 1.50 153 2.0 821013 1500 1.53 162 2.0 ~821013 1600 1.50 153 2.0 821013 1700 1.50 153 2.0 821013 1800 1.50 153 2.0 821013 1900 1.50 1~3 2.0,.....821013 2000 1.50 153 2.0 821013 2100 1.50 153 2.0 821013 2200 1.50 153 1.5 ,....821013 2300 1.50 153 1.5 821013 2400 1.50 153 1.5 821013 DAILY MEAN 1.53 160 1.7 821014 0100 1.50 153 1.5 821014 0200 1.50 153 1.0 .-821014 0300 1.50 153 1.5 821014 0400 1.50 153 1.0 821014 0500 1.50 153 1.0 821014 0600 1.47 144 1.0-821014 0700 1.47 144 1.0 821014 0800 1.47 144 1.0 821014 0900 1.47 144 1.0-821014 1000 1.47 144 1.0 ------------------------------------------------------------- 4-A-117 4-A-llB -I Table 4-A-4.Cant. --------------~-~----------*-~-------._---~--------SUlt:FACE: GAGE WATER HEIGRT DISCHARGE TEMPERA'l'URE DATE TIME (tt)(cis)(C)------------'-'.,.,..;.,-j.,..'.......-..'.._----........-.._~--..........~--- 821017 1400 1.43 136 2.5 821017 1500 1043 136 2 ..5 821017 1600 1043 136 2.5 821017 1700 1043 136 2.0 821017 1800 1.43 136 2.0 821017 1900 1.43 136 2.() 821017 2000 ·1.43 136 1.5 821017 2100 1043 136 1 ..5 821017 2200 1.43 136 100 821017 2300 1043 136 100 821017 2400 1043 136 .s 821017 DAILY MEAN 1043 136 1.6 821018 0100 1043 136 .5 821018 0200 1.43 136 0.0 821018 0300 1040 129 0.0 821018 0400 1040 129 0.0 821018 0500 1040 129 0.0 821018 0600 1.40 129 0.0 821018 0700 1.40 129 0.0 821018 0800 1040 129·0.0 821018 0900 1.40 129 0.0 821018 1000 1040 129 0.0 821018 1100 1~40 129 .5 821018 1200"1040 129 .5 821018 1300 1040 129 .5 821018 1400 1.40 129 1.0 821018 1500'1040 129 1.0 821018 1600 1040 129 1.5 821018 1700 1.40 129 100 821018 1800 1040 129 105 821018 1900 1040 129 1.5 821018 2000 1.43 136 1.0 821018 2100 1040 129 1.0 821018 2200 1'.40 129 1.0 821018 2300 1040 129 l.O 821018 2400 1.40 129 100. 821018 DAILY MEAN 1.40 130 .6 821019 0100 L40 129 1.0 4-A-120 .... - ...... - Table 4-A-4.Cont.-, -~~---------------------------------------------------~~--SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE .TIME (ft )(cfs)(C) -------------------------------------~-----~------------- 821019 0200 1.40 129 1.0 821019 0300 1.40 129 1.0 821019 '0400 1.40 129 1.0 821019 0500 1.40 129 1.0 821019 0600 1.40 129 1.0 821019 0700 1.40 129 .5 821019 0800 1.40 129 .5 821019 0900 1.40 129 0.0 821019 1000 1.40 129 .5 821019 1100 1.43 136 .5 821019 1200 1.40 129 .5 821019 1300 1.40 129 1.0 821019 1400 1.40 129 1.0 821019 1500 1.40 129 1.5-821019 1600 1.40 129 1.5 821019 1700 1.40 129 1.5 821019 1800 1.40 129 1.5 ~r~\821019 1900 1.40 129 1.5 821019 2000 1.40 129 1.5 821019 2100 1.40 129 1.5 821019 '2200 1.40 129 1.5 821019 2300 1.40 129 1.0 821019 2400 1.40 129 1.0 821019 DAILY MEAN 1.40 129 1.0 821020 0100 1.40 129 1.0 .821020 0200 1.40 129 1.0 821020 0300 1.40 129 .5 821020 0400 1.40 129 .5 821020 0500 1.37 121 .5 ,~821020 0600 1.37 121 .5 821020 0700 1.40 129 .5 821020 0800 1.37 121 .5 821020 0900 1.37 121 .5 821020 1000 1.37 121 .5 821020 1100 1.37 121 .5 821020 1200 1.37 121 1.0 821020 1300 1.37 121 1.0 821020 1400 1.37 121 1.0 821020 1500 1.37 121 1.0 821020 1600 1.37 121 1.0. ------------------------------------------------------------- 4-A-121 Table 4-A-4.Cont. SURFACE GAGE WATER HEIGHT DISCHARGE TE:MPERATURE DATE TIME (ft)(cis)(~) ----------------------------~__~..__...._.~._...:.i.~~_~w.____ 821020 1700 1.37 121 1.0 821020 1800 1.37 121 1.0 821020 1900 1.37 1:21 .5 821020 2000 Ie37 121 .5 821020 2100 10.37 121 .5 821020 2200 1.37 121 0.0 821020 2300 1.37 121 0.0 821020 2400 Ie37 12i 0.0 821020 DAllY MEAN 1.37 123 .6 821021 0100 1.33 114 0.0 821021 0200 1.33 114 0,.0 821021 0300 1.33 114 0.0 821021 0400 1.33 114 O~O 821021 0500 Ie33 114 0.0 821021 0600 1.33 114 "0.0 821021 0700 1.33 114 0 ..0 821021 0800 1~33 114 0.0 821021 0900 1.33 114 0.0 821021 1000 Ie33 114 0.0 821021 1100 Ie30 108 0.0 821021 '1200 1.30 108 0.0 821021 1300 1.30 10~0.0 821021 1400 1.30 108 '0.0 821021 1500 1.30 108 0.0 821021 1600 1.30 108 0.0 821021 1700 1.30 108 0.0 821021 1800 1.30 108 0.0 821021 1900 1.30 108 0.0 821021 2000 1.30 108 0.0 821021 2100 1.30 108 0.0 821021 2200 10.30 108 '0.0 821021 2300 1.27 101'0.0 821021 2400 1.27 101 0.0 821021 DAILY MEAN 1.31 110 0.0 821022 0100 1.27 101 0.0 821022 0200 1.30 108 0.0 821022 0300 1.30 108 0.0 821022 0400 1.30 108 0.0 ______~____~__~~_'_..:_~~M:~-;~';<:'.-...;.,-~~.....;.---~... 4-A-122 - - - ""'" ,"""'"Table 4-A-4.Cont. ""'"'------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) -------------------------------------------- 821022 0500 1.30 108 0.0 821022 0600 1.30 108 0.0 821022 0700 1.30 108 0.0 821022 0800 1.30 108 0.0 821022 0900 1.30 108 0.0 821022 1000 1.30 108 0.0 821022 1100 1.30 108 0.0 ~821022 1200 1.30 108 0.0 821022 1300 1.30 108 0.0 821022 1400 1.30 108 0.0 821022 1500 1.33 114 0.0 821022 1600 1.37 121 0.0 821022 1700 1.33 114 0.0 821022 1800 1.33 114 0.0 821022 1900 1.33 114 0.0 821022 2000 1.33 114 0.0 821022 2100 1.37 121 0.0 ,~,821022 2200 1.37 121 0.0 821022 2300 1.37 121 0.0 821022 2400 1.37 121 0.0 821022 DAILY MEAN 1.32 111 0.0 --------------------------------------------------------- ..... 4-A-123 - I 11~Table 4-A-S.Cont. ....---------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERA TURE DATE TIME (ft)(cfs)(C) -------------------------- 820810 0100 2.17 598 7.5 820810 0200 2.13 582 7.5 820810 0300 2.17 598 7.5 820810 0400 2.17 598 7.5 820810 0500 2.17 598 7.0 820810 0600 2.17 598 7.0 820810 0700 2.17 598 7.0 820810 0800 2.17 598 7.0 820810 0900 2.20 615 7.5 820810 1000 2.20 615 7.0 """820810 1100 2.23 632 7.5 820810 1200 2.23 632 8.0 820810 1300 2.23 632 8.0 820810 1400 2.23 632 8..5 820810 1500 2.27 649 8.5 820810 1600 2.27 649 8.5 820810 1700 2.27 649 9.0 ~_of~i"!h.,820810 1800 2.27 649 8.5 820810 1900 2.27 649 8.5 820810 ~OOO 2.27 649 8.5 820810 2100 2.27 649 8.5 820810 2200 2.27 649 8.0 820810 2300 2.27 649 8.0 820810 2400 2.27 649 8.0-820810 DAILY MEAN 2.22 625 7.9 820811 0100 2.23 632 7.5 820811 0200 2.27 649 7.5 820811 0300 2.23 632 7.5 820811 0400 2.23 632 7.0 ~820811 0500 2.23 632 7.0 820811 0600 2.20 615 7.0 820811 0700 2.20 615 7.0 820811 0800 2.20 615 7.0 F"820811 0900 2.17 598 7.0 820811 1000 2.17 598 7.0 820811 1100 2.17 598 7.5-820811 1200 2.17 598 8.5 820811 1300 2 .17 598 9.0 820811 1400 2.13 582 11.0 820811 1500 2.13 582 11.0 ------------------------------------------------------------ 4-A-125 11I\I'!fi'll; Table 4-A-5.Cont. .."., ,.-,----------_..._------------------_..._- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)----------.---~------------------~~--------~----- 820811 1600 2.13 582 12.0 820811 1700 2.10 565 10.5 820811 1800 2.10 565 10.5 820811 1900 2.10 565 10.0 820811 2000 2.10 565 10.0 820811 2100 2.10 565 9.5 820811 2200 2.10 565 9.5 820811 2300 2.10 565 9.0 820811 2400 2.07 549 8.5 ~ 820811 DAILY MEAN 2.16 594 8.7 820812 0100 2.07 549 8.0 820812 0200 2.07 549 7.5 820812 0300 2.07 549 7.5 820812 0400 2.07 549 7.0 ~I 820812 0500 2.07 549 6.5 820812 0600 2.07 .549 6.5 820812 0700 2.03 533 6.0 820812 0800 2.07 549 6.0 ~.- 820812 0900 2.03 533 6.0 820812 1000 2.03 533 6.0 820812 1100 2.03 533 6.5 -820812 1200 2.03 533 .7.5 820812 1300 2.00 516 10.5 820812 1400 2.00 516 11.0 820812 1500 2.00 516 11.5 .."., , 820812 1600 2.00 516 11.5 820812 1700 1.97 500 11.5 820812 1800 2.00 516 10.5 ~ 820812 1900 1.97 500 10.5 820812 2000 2.00 516 10.5 820812 2100 1.97 500 10.5 820812 2200 2.00 516 .10.0 820812 2300 2.00 516 9.5 820812 2400 1.97 500 9.5 -820812 DAILY MEAN 2.02 527 8.7 820813 0100 1.97 500 9.0 820813 0200 1.97 500 8.5 ~- 820813 0300 1.97 500 8.0 -----------,---------.--...--------..----..~ 4-A-126 4-A-127 .....4-A-129 """" Table 4-A-S.Cont. t"""----------------------------------------------~-------------SURFACE ~GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)--------------------..---------.------ 820817 2200 1.93 484 8.5 820817 2300 1.93 484 8.0 820817 2400 1.93 484 8.0 820817 DAILY MEAN 1.89 464 8.6 ""'"820818 0100 1.93 484 8.0 820818 0200 1.93 484 7.5 820818 0300 1.93 484 7.5 820818 0400 1.90 468 7.0 -. 820818 0500 1.90 468 7.0 820818 0600 1.90 468 7.0 820818 0700 1.90 468 7.0 ~ 820818 0800 1.90 468 7.5 I 820818 0900 1.90 468 7.5 820818 1000 1.87 453 7.5 820818 1100 1.87 453 8.0 820818 1200 1.87 453 8.5 820818 1300 1.87 453 9.0 820818 1400 1.87 453 9.0 ~"""820818 1500 1.87 453 9.5 820818 1600 1.87 453 9.5 820818 1700 1.83 437 9.5 820818 1800 1.83 437 10.0 - 820818 1900 1.83 437 9.5 820818 2000 1.83 437 9.5 820818 2100 1.83 437 9.0 820818 2200 1.83 437 9.0 820818 2300 1.83 437 8.5 820818 2400 1.83 437 8.5 820818 DAILY MEAN 1.87 455 8.4 820819 0100 1.83 437 8.0 -820819 0200 1.83 437 7.5 820819 0300 1.83 437 7.5 820819 0400 1.80 421 7.0 820819 0500 1.83 437 7.0 820819 0600 1.80 421 6.5 820819 0700 1.80 421 6 ..5 820819 0800 1.80 421 6.5 820819 0900 1.80 421 7.0 ---------------~---------~-------------------------- 4-A-130 4-A-131 4-A-132 1""" Table 4-A-5.Cont. ~ ~-------------------------------------------------------------SURFACE GAGE WATER....HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(Cfs)(C) ------------------------------------------------------------- 820822 1300 1.67 360 10.0 820822 1400 1.67 360 10.5 820822 1500 1.67 360 12.0 ,-820822 1600 1.67 360 11.5 820822 1700 .1.63 345 11.5 820822 1800 1.67 360 11.0 820822 1900 1.63 345 11.0 820822 2000 1.67 360 11.0 820822 2100 1.63 345 11.0 820822 2200 1.63 345 10.5 8:l0822 2300 1.67 360 10.5 820822 2400 1.67 360 10.5 820822 DAILY MEAN 1.67 359 9.4 820823 0100 1.67 360 10.0 820823 0200 1.63 345 10.0--,820823 0300 1.67 360 9.5 820823 0400 1.67 360 9.5 820823 0500 1.67 360 9.5 820823 0600 1.67 360 9.0 II!IlIiA 820823 0700 1.67 360 9.0 820823 0800 1.67 360 9.0 820823 0900 1.67 360 9.0 820823 1000 1.67 360 9.0 820823 1100 1.67 360 9.0 820823 1200 1.67 360 9.5 820823 1300 1.70 375 10.0 820823 1400 1.70 375 10.0 820823 1500 1.70 375 10.5 820823 1600 1.70 375 10.5 820823.1700 1.70 375 10.0 820823 1800 1.70 375 10.5 820823 1900 1.70 375 10.5 820823 2000 1.73 390 10.5-820823 2100 1.70 375 10.5 820823 2200 1.73 390 10.0 820823 2300 1.73 390 10.0 820823 2400 1.73 390 9.5 820823 DAILY MEAN 1.69 369 9.8 """'I I -------------------------------------------------------------I - 4-A-133 4-A-134 4-A-135 4-A-136 Table 4-A-S.Cont. t""'"--------------------------------------- SURFACE ~ GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)------------------------------------------- 820830 0700 1.97 500 7.5 820830 0800 2.00 516 7.5 820830 0900 2.00 516 7.5 820830 1000 2.03 533 7.5 820830 1100 2.07 549 7.5 820830 1200 2.10 565 7.5 ~. 820830 1300 2.17 598 7.5 820830 1400 2.20 615 7.5 820830 1500 2.27 649 7.5 l@i'If' 820830 1600 2.33 682 7.5 820830 1100 2.40 716 7.5 820830 1800 2.43 734 7.5 820830 1900 2.50 768 7.5 ~ 820830 2000 2.50 768 7.5 820830 2100 2.53 786 7.5 820830 2200 2.53 786 7.0 -820830 2300 2.53 786 7.0 820830 2400 2.53 786 7.0 820830 DAILY MEAN 2.19 609 •7.5 ,.-.,"""" 820831 0100 2.53 786 7.0 820831 0200 2.53 786 7.0 I"!'l1 820831 0300 2.57 803 7.0 820831 0400 2.57 803 7.0 820831 0500 2.57 803 6.5 820831 0600 2.60 821 6.5 820831 0700 2.57 803 6.5 820831 0800 2.57 803 6.5 820831 0900 2.57 803 6.5 -820831 1000 2.57 803 6.5 820831 1100 2 .53 786 7.0 820831 1200 2.53 786 7.0 820831 1300 2.50 768 7.0 820831 1400 2.47 751 7.5 820831 1500 2.50 768 8.0 820831 1600 2.47 751 8.0 820831 1700 2.43 734 8.0 820831 1800 2.43 734 8.0 820831 1900 2.40 716 8.0 820831 2000 2.43 734 8.0 820831 2100 2.40 716 8.0 --------------_...._----_.......------------------ 4-A-138 L....,. ~lA, ~~.....Table 4-A-S.Cont. ~-------------------------------------------------------------- SURFACE GAGE WATER-HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft).(efs)(C) --------------------------------------------------------.820831 2200 2.37 699 7.5 820831 2300 2.40 716 7.5 820831 2400 2.40 716 7.5 820831 DAILY MEAN 2.50 766 7.3 820901 0100 2.40 716 7.0 820901 0200 2.40 716 7.0 820901 0300 2.37 699 7.0 820901 0400 2.33 682 7.0 820901 0500 2.37 699 7.0 820901 0600 2.33 682 7.0 820901 0700 2.33 682 6.5 r-820901 0800 2.33 682 6.5 820901 0900 2.33 682 7.0 820901 1000 2.37 699 7.0 820901 1100 2.33 682 7.5 ~~"820901 1200 2.33 682 7.5 820901 1300 2.30 665 8.0 820901 1400 2.30 665 8.0 ~820901 1500 2.30 665 8.5 820901 1600 2.30 665 8.5 820901 1700 2.30 665 8.5 820901 1800 2.27 649 8.5 820901 1900 2.27 649 9.0 820901 2000 2.27 649 8.5 820901 2100 2.27 649 8.5-820901 2200 2.23 632 8.0 820901 2300 2.27 649 7.5 820901 2400 2.23 632 7.5 r-820901 DAILY MEAN 2.31 672 7.6 820902 0100 2.23 632 7.0 .-820902 0200 2.23 632 7.0 820902 0300 2.23 632 6.5 820902 0400 2.23 632 6.5 820902 0500 2.23 632 6.5 820902 0600 2.20 615 6.5 820902 0700 2.20 615 6.5 820902 0800 2.20 615 6.5 820902 0900 2.20 615 6.5 ------------------------------------------ -4-A-139 Table L,\-A-5.Cont. ---------------~.---_-------------- SURFACE .~ GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)--.e-o-__________________________._~___ 820902 1000 2.20 615 7.0 820902 1100 2.20 615 7.0 -820902 1200 2.17 598 7.5 820902 1300 2.17 598 8.0 820902 1400 2.17 598 8~5 820902 1500 2.17 598 8.5 -820902 1600 2.17 598 8.5 820902 1700 2.13 582 8.5 820902 1800 2.13 582 8.5 ~820902 1900 2.17 598 8.5 820902 2000 2.17 598 8.5 820902 2100 2.20 615 8.0 820902 2200 2.20 615 8.0 -820902 2300 2.20 615 7.5 820902 2400 2.23 632 7.5 820902 DAILY MEAN 2.19 612 7.5 820903 0100 2.20·615 7.5 820903 0200 2.23 632 7.5 c~- 820903 0300 2.23 632 7.0 820903 0400 2.27 649 7.0 820903 0500 2.27 649 7.0 820903 0600 2.27 649 7.0 820903 0700 2.30 665 6.5 820903 0800 2.30 665 6.5 820903 0900 2.33 682 6.5 ~ 820903 1000 2.33 682 6.5 820903 1100 2.33 682 6.5 820903 1200 2.37 699 7.0 820903 1300 2.37 699 7.0 820903 1400 2.37 699 7.0 820903 1500 2.37 699 7.5 820903 1600 2.37 699 7.5 820903 1700 2.37 699 7.5 820903 1800 2.37 699 7.5 820903 1900 2.40 716 7.5 '-820903 2000 2.40 716 7.5 820903 2100 2.40 716 7.0 820903 2200 2.37 699 7.0 820903 2300 2.40 716 7.0 ~ 820903 2400 2.37 699 7.0 --------------------------------------------------------- - 4-A-140 -, >~~,Table 4-A-5.Cont. -------------------------------------------------------------SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cis)(C) --------------------------------------- 820903 DAILY MEAN 2.33 682 7.1 820904 0100 2.37 699 6.5 820904 0200 2.33 682 6.5 820904 0300 2.33 682 6.5 820904 0400 2.33 682 6.5 820904 0500 2.33 682 6.0 820904 0600 2.33 682 6.0 820904 0700 2.30 665 6.0 820904 0800 2.30 665 6.0 820904 0900 2.30 665 6.0 820904 1000 2.30 665 6.5 820904 1100 2.30 665 6.5 820904 1200 2.30 665 7.0 820904 1300 2.27 649 7.5 820904 1400 2.27 649 8.0 ,-.,820904 1500 2.27 649 8.0 820904 1600 2.27 649 9.0 820904 1700 2.27-649 8.0 820904 1800 2.23 632 8.5 820904 1900 2.23 632 8.0 820904 2000 2.23 632 7.5 820904 2100 2.27 649 7.5 820904 2200 2.23 632 7.5 820904 2300 2.23 632 7.5 820904 2400 2.23 632 7.0 820904 DAILY MEAN 2.28 658 7.1 820905 0100 2.23 632 7.0 820905 0200 2.20 615 _6.5 820905 0300 2.23 632 6.5 820905 0400 2.20 615 6.5 820905 0500 2.23 632 6.0 820905 0600 2.23 632 6.0 820905 0700 2.23 632 6.0 820905 0800 2.20 615 6.0 820905 0900 2.20 615 6.0 820905 1000 2.20 615 6.5 820905 1100 2.20 615 6.5 820905 1200 2.20 615 6.5r- -----------~------------------------------------------------ ~ 4-A-141 4-A-142 4-A-143 ~ Table 4-A-5.Cont. -'>------------------------------------- SURFACE !""I\ GAGE WATER HEIGHT DISCHARGE TEMPERATURE, DATE TIME (ft)(ds)(C) -------------------------------- 820908 1600 2.07 549 7.0 ,820908 1700 2.07 549 7.0 ~ 820908 1800 2.07 '549 7.0 820908 1900 2.07 549 7.5 820908 2000 2.07 549 7.0 820908 2100 2.07 549 7.0 820908 2200 2.07 549 7.0 820908 2300 2.07 549 7.0 820908 2400 2.07 549 7.0 820908 DAILY MEAN 2.09 563 7.0 820909 0100 2.07 549 6.5 - 820909 0200 2.07 549 6.5 820909 0300 2.07 549 6.5 820909 0400 2.07 549 6.5 820909 0500 2.07 549 6.5 820909 0600 2.07 549 '6.5 820909 0700 2.07 549 6.5 820909 0800 2.10 565 6.5 ~.- 820909 0900 2.07 549 6.5 820909 1000 2.07 549 6.5 820909 1100 2.07 549 6.5 -820909 1200 2.07 549 7.0 820909 1300 2.07 549 7.0 820909 1400 2.07 549 7.5 820909 1500 2.07 549 7.5 - 820909 1600 2.07 549 7.5 820909 1700 2.10 565 7.5 820909 1800 2.07 549 7.5 820909 1900 2.10 565 7.5 820909 2000 2.10 565 7.5 820909 2100 2.10 565 7.5 820909 2200 2.13 582 7.0 820909 2300 2.13 582 7.0 820909 2400 2.17 598 7.0 820909 DAILY MEAN 2.08 557 6.9 820910 0100 2.17 598 7.0 820910 0200 2.17 598 6.5 -820910 0300 2.17 598 6.5 ----------------------------------~ - 4-A-144 - 4-A-145 """4-A-147 4-A-149 Table 4-A-S.Cont. """', ---------------------------------------- SURFACE -GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(ds)(C) ----_.._-----------------------~---- 820917 DAILY MEAN 3.73 1391 5.2 820918 0010 3.60 1317 5.0 820918 0110 3.53 1279 5.0 820918 0210 3.53 1279 5.0 ....820918 0310 3.50 1260 5.0 820918 0410 3.47 1241 4.5 820918 0510 3.47 1241 4.5 820918 0610 3.43 1222 4.5 820918 0710 3.43 1222 4.5 820918 0810 3.43 1222 4.5 820918 0910 3.43 1222 5.0 ~820918 1010 3.40 1203 5.0 820918 1110 3.40 1203 5.0 820918 1210 3.37 1184 5.5 820918 1310 3.40 1203 6.0 ~ 820918 1410 3.33 1166 6.0 820918 1510 3.37 1184 6.0 820918 1610 3.33 1166 6.0 ~-,820918 1710 3.33 1166 6.0 820918 1810 3.33 1166 6.5 820918 1910 3.33 1166 6.0 820918 2010 3.37 1184 6.0 820918 2110 3.33 1166 6.0 820918 2210'3.37 1184 6.0 820918 2310 3.40 1203 6.0 ~ 820918 DAILY MEAN 3.41 1210 5.4 820919 0010 3.40 1203 6.0 ...... 820919 0110 3.40 1203 6.0 820919 0210 3.40 1203 6.0 820919 0310 3.40 1203 5,.5 ....820919 0410 3.43 1222 5.5 820919 0510 3.47 1241 6.0 820919 0610 3.47 1241 5.5 820919 0710 3.40 1203 5.5 -820919 0810 3.43 1222 5.5 820919 0910 3.50 1260 5.5 820919 1010 3.50 1260 6.0 ~,820919 1110 3.50 1260 5.5 820919 1210 3.63 1336 6.0 -----------~------------------------------------------------ 4-A-150 .- -Table 4-A-5.Cont. -------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) ------------------------------------------- 820919 1310 3.70 1375 6.0 820919 1410 3.63 1336 6.0 820919 1510 3.73 1394 6.0 820919 1610 3.73 1394 6.0 820919 1710 3.73 1394 6.0 820919 1810 3.67 '1355 6.0 820919 1910 3.73 1394 6.0 820919 2010 3.77 1413 6.0 820919 2110 3.77 1413 6.0 820919 2210 3.77 '1413 6.0 820919 2310 3.87 1472 5.5 820919 DAILY MEAN 3.58 1308 5.8 r~820920 0010 3.90 1491 5.5 820920 0110 3.83 1452 5.5 . 820920 0210 3.83 1452 5.5/-820920 0310 3.80 1433 5.5 820920 0410 3.80 1433 5.5 820920 0510 3.77 1413 5.5 820920 0610 3.77 1413 5.0 820920 0710 3.73 1394 5.0 820920 0810 3.77 1413 5.0 820920 0910 3.73 1394 5.0-820920 1010 3.73 1394 5.5 820920 1110 3.73 1394 5.5 820920 1210 3.70 1375 5.5 820920 1310 3.63 1336 5.5 820920 1410 3.67 1355 6.0 820920 1510 3.63 1336 6.0 820920 1610 3.67 1355 6.0-820920 1710 3.60 1317 6.0 820920 1810 3.63 1336 6.0 820920 1910 3.60 1317 5.5 820920 2010 3.57 1298 6.0 820920 2110 3.57 1298 5.5 820920 2210 3.60 1317 5.5 820920 2310 3.53 1279 5.5 820920 DAILY MEAN 3.70 1375 5.5 820921 0010 3.53 1279 5.5.- ~_._--------------------------------------------------------- 4-A-151 Table 4-A-S.Cant. ~ ,...,,' ----------------------------------------~--------------------SURFACE ~ GAGE WATER HEIGHT DISCHARGE TEMPERA TURE DATE TIME (ft)(cfs)(C)------~___________=r...____..______________ 820921 0110 3.57 1298 5.5 820921 0210 3.53 1279 5.0 -820921 0310 3.57 1298 5.0 820921 0410 3.50 1260 5.0 820921 0510 3.47 1241 5.0 820921 0610 3.50 1260 5.0 -. 820921 0110 3.50 1260 5.0 820921 0810 3.53 1279 5.0 820921 0910 3.47 1241 5.0 820921 1010 3.47 1241 5.0 820921 1110 3.43 1222 5.5 820921 1210 3.43 1222 5.5 820921 1310 3.40 1203 5.5 820921 1410 3.37 1184 6.0 820921 1510 3.40 1203 6.0 820921 1610 3.40 1203 6.0 i\li.III'F!!lj 820921 1710 3.43 1222 6.0 820921 1810 3.37 1184 6.0 820921 1910 3.40 1203 6.0 820921 2010 3.37 1184 6.0 ~""'-; 820921 2110 3.37 1184 6.0 820921 2210 3.37 1184 5.5 820921 2310 3.33 1166 5.5 820921 DAILY MEAN 3.45 1229 5.5 820922 0010 3.37 1184 5.5 -820922 0110 3.33 1166 5.5 820922 0210 3.33 1166 5.5 820922 0310 3.33 1166 5.0 820922 0410 3.30 1147 5.0 820922 0510 .3.30 1147 5.0 820922 0610 3.27 1128 5.0 820922 0710 3.30 1147 5.0 .@Il;1 820922 0810 3.23 1110 5.0 820922 0910 3.27 1128 5.0 820922 1010 3.23 1110 5.0 820922 1110 3.23 1110 5.0 820922 1210 3.23 1110 5.5 820922 1310 3.23 1110 5.5 820922 1410 3.20 1091 5.5 820922 1510 3.23 1110 6.0 -------------------------------------------------------------- ~','\ ~ 4-A-152 - 4-A-153 ~ Table 4-A-5.Cont. """'1 '-i~'------------------------------------- SURFACE -GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C) ~,------------------------------------------------------- 820924 0410 2.87 909 3.0 820924 0510 2.90 927 3.0 ~ 820924 0610 2.87 909 2.5 820924 0710 2.87 909 2.5 820924 0810 2.87 909 2.5 820924 0910 2.87 909 2.5 820924 1010 2.83 891 2.5 820924 1110 2.80 874 3.0 820924 1210 2.80 874 3.0 820924 1310 2.80 874 3.5 820924 1410 2.80 874 4.5 820924 1510 2.80 874 4.5 820924 161.0 2.80 874 4.5 820924 1710 2.80 874 4.5 820924 1810 2.80 874 4.5 820924 1910 2.80 874 5.0 "l!'<ll 820924 2010 2.77 856 5.0 820924 2110 2.77 856 4.5 820924 2210 2.77 856 4.5 820924 2310 2.80 874 4.5 ~"""" 820924 DAILY MEAN 2.83 891 3 .6 ~ 820925 0010 2.77 856 4.5 820925 0110 2.77 856 4.0 820925 .0210 2.77 856 4.0 820925 0310 2.70 821 3.5 IJ!IIII!l'lI!, '820925 0410 2.73 838 3.5 820925 0510 2.73 838 3.5 820925 0610 2.73 838 3.0 -820925 0710 2.73 838 3.0 820925 0810 2.73 838 3.0 820925 0910 2.70 821 3.0 820925 1010 2.67 803 3.0 820925 1110 2.70 821 3.5 820925 1210 2.70 821 3.5 820925 1310 2.67 803 4.5 820925 1410 2.67 803 4.5 820925 1510 2.67 803 5.0 820925 1610 2.67 803 5.0 820925 1710 2.67 803 5.•0 820925 1810 2.67 803 5.0 --------------......._-----------------_....._------------------- /..-st'~", 4-A-154 - 4-A-155 ~ Table 4-A-5.Cont. """"" ------------------------------------------------------------- SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERA TURE DATE TIME (ft )(ds)(C) ------------------------------------------------------ 820928 2210 2.43 682 4.0 820928 2310 2.43 682 4.0 820928 DAILY MEAN 2.45 691 3.5 820929 0010 2.43 682 4.0 820929 0110 2.43 682 4.0 820929 0210 2.43 682 4.0 820929 0310 2.43 682 4.0 820929 0410 2.47 699 4.0 820929 0510 2.43 682 4.0 .820929 0610 2.43 682 4.0 820929 0710 2.43 682 3.5 820929 0810 2.43 682 3.5 820929 0910 2.43 682 4.0 820929 1010 2.40 665 4.0 820929 1110 2.40 665 4.0 ...~820929 1210 2.43 682 4.5 820929 1310 2.40 665 4.5 820929 1410 2.40 665 5.0 820929 1510 2.40 665 5.0 r""820929 1610 2.40 665 5.0 820929 1710 2.37 649 5.0 820929 1810 2.37 649 5.0 820929 1910 2.40 665 5.0 820929 2010 2.37 649 5.0 820929 2110 2.37 649 5.0 820929 2210 2.37 649 5.0 820929 2310 2.40 665 5.0 820929 DAILY MEA..'l"2.41 670 4.4-820930 0010 2.40 665 5.0 820930 0110 2.40 665 4.5 820930 0210 2.40 665 4.5 820930 0310 2.43 682 4.5 820930 0410 2.43 682 4.5 820930 0510 2.43 682 4.5 .-.820930 0610 2.43 682 4.5 820930 0710 2.43 682 4.0 820930 0810 2.40 665 4.0 820930 0910 2.43 682 4.0 ~--------------------------------------------------------~ 4-A-157 4-A-159 ~ Table 4-A-5.Cont.....-,------------------------------------------------------------- SURFACE -G.AGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)---------------------------------------- 821003 1310 2.13 533 4.0 821003 1410 2.13 533 4.0 ,.." 821003 1510 2.17 549 4.5 821003 1610 2.17 549 4.0 821003 1710 2.13 533 4.0 821003 1810 2 .13 533 4.0 iIiiIll"fi 821003 1910 2.13 533 4.0 821003 2010 2.13 533 4.0 821003 2110 2.17 549 4.0 ~821003 2210 2.13 533 4.0 821003 2310 2.13 533 3.5 821003 DAILY MEAN 2.16 544 3.6 .... 821004 0010 2.13 533 3.5 821004 0110 2.13 533 3.0 821004 0210 2.13 533 3.0 821004 0310 2.13 533 3.0 821004 0410 2.10 516 2.5 821004 0510 2.13 533 2.5 ,_"""'I 821004 0610 2.10 516 2.5 821004 0710 2.10 516 2.0 821004 0810 2.10 516 2.0 -821004 0910 2.10 516 2.0 821004 1010 2.10 516 2.0 821004 1110 2.10 516 1.5 821004 t210 2.07 500 2.0 821004 1310 2.07 500 2.5 821004 1410 2.07 500 3.0 821004 1510 2.07 500 3.5 ~ 821004 1610 2.07 500 3.0 821004 1710 2.07 500 3.0 821004 1810 2.07 500 3.0 821004 1910 2.07 500 3.0 ~ 821004 2010 2.07 500 2.5 821004 2110 2.07 500 2.5 821004 2210 2.07 500 2.5 821004 2310 2.07 500 2.5 821004 DAILY MEAN 2.09 .512 2.6 ~ 821005 0010 2.07 500 2.0 -------------------------------------------------------~I '""'" 4-A-160 Table 4-A-5.Cont. ------~-------------~------~-----------------~--SURFACE GAGE WATER HEIGHT DISCHARGE TEMPERA TURE DATE TIME (ft)(cfs)(C) ~-------------------------------------- 821006 1610 1.93 437 2.5 821006 1710 1.97 .453 2.5 821006 1810 1.97 453 2.5 821006 .1910 1.97 453 2.5 821006 2010 1.97 453 2.0 821006 2110 2.00 468 2.0 -821006 2210 1.97 453 2.0 821006 2310 1.97 .453 2.0 ~; 821006 DAILY MEAN 1.96 449 1.5 821007 0010 1.97 453 1.5 821007 0110 2.00 468 1.5 ~, 821007 0210 1.97 453 1.5 821007 0310 1.97 453 1.5 821007 0410 1.93 437 1.5 ~ 821007 0510 1.97 453 1.5 821007 0610 1.93 437 1.5 821007 0710 1.93 437 1.5 821007 0810 1.93 437 •1.5 ,~.~ 821007 0910 1.93 437 1.5 821007 1010 1.93 437 1.5 821007 1110 1.93 437 1.5 821007 1210 1.93 437 1.5 821007 1310 1.93 437 1.5 821007 1410 1.93 437 1.5 821007 1510 1.93 437 2.0 821007 1610 1.93 437 2.0 821007 1710 1.93 437 2.0 821007 1810 1.93 437 2.0 ~ 821007 1910 1.93 437 2.0 821007 2010 1.93 437 2.0 821007 2110 1.93 437 2.0 821007 2210 1.93 :437 1.5 821007 2310 1.93 437 1.5 821007 DAILY MEAN 1.94 441 1.6 821008 0010 1.93 437 1.5 821008 0110 1.93 437 1.5 821008 0210 1.93 437 1.5 821008 0310 1.93 437 1.5 -----------------.-.---------------------------------------~ iMmI', 4-A-162 -4-A-163 4-A-164 -, 4-A-165 4-A-166 ~, '""" ""'.4-A-167 4-A-168 4-A-169 Table 4-A-5.Cont.~ ~... --------------_______________•••••:II•.•------- SURFACE -GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfa)(C)~-___________...a-___...........___________••••_________ 821019 0110 1.63 300 0.0 821019 0210 1.60 286 0.0 -821019 0310 1.60 286 0.0 821019 0410'1.60 286 0.0 821019 0510 1.60 286 0.0 821019 0610 1.60 286 0.0 821019 0710 1.60 286 0.0 821019 0810 1.60 286 0.0 821019 0910 1.60 286 0.0 ~ 821019 1010 1.60 286 0.0 821019 1110 1.63 300 0.0 821019 1210 1.63 300 0.0 ~ 821019 1310 1.63 300 0.0 821019 1410 1.63 300 0.0 821019 1510 1.63 300 0.0 821019 1610 1.60 286 0.0 ~ 821019 1710 1.60 286 0.0 821019 1810 1.60 286 0.0 821019 1910 1.60 286 .5 ~-821019 2010 1.60 286 .5 821019 2110 1.60 286 .5 821019 2210 1.60 286 .5 821019 2310 1.60 286 0.0 - 821019 DAILY MEAN 1.61 290 ,,1 ~ 821020 0010 1.60 286 0.0 821020 0110 1.60 286 0.0 821020 0210 1.57 271 0.0 821020 0310 1.60 286 0.0 821020 0410 1.60 286 0.0 821020 0510 1.57 271.0.0 821020 0610 1.57 271 0.0 821020 0710 1.57 271 0.0 821020 0810 1.53 257 0.0 821020 0910 1.57 271 0.0 821020 1010 1.53 257 0.0 821020 1110 1.53 257 0.0 821020 1210 1.53 257 0.0 821020 1310 1.53 257 0.0 ~821020 1410 1.53 257 0.0 821020 1510 1.53 257 0.0 ------------_____~______~___T ---------_.---------- 4-A-170 ""'" 4-A-171 ",""" Table 4-A-5.Cant.- ""~------------------------------------------------------------ SURFACE ~ GAGE WATER HEIGHT DISCHARGE TEMPERATURE DATE TIME (ft)(cfs)(C)--------------.---------------------....------ 821022 0410 1.40 201 0.0 821022 0510 1.40 201 0.0 -821022 0610 1.40 201 0.0 821022 0710 1.40 201 0.0 821022 0810 1.40 201 0.0 821022 0910 1.40 .201 0.0 -821022 1010 1.40 201 0.0 821022 1110 1.40 .201 0.0 821022 1210 1.40 201 b.o ~ 821022 1310 1.40 201 0.0 821022 1410 1.40 201 0.0 821022 1510 1.40 201 0.0 821022 1610 1.43 215 0.0 -821022 1710 1.43 215 0.0 821022 1810 1.43 215 .0.0 821022 1910 1.47 229 0.0 821022 2010 1.47 229 0.0 821022 2110 1.47 229 0.0 821022 2210 1.47 229 0.0 821022 2310 1.47 229 0.0 .-..- 821022 DAILY MEAN 1.42 208 0.0 -----.-----------------------------..--------- 4-A-172 - ---,Appendix Table 4-A-6.Comparison of periodic water surface elevations (WSEL)and measured flow at selected sites located-downstream of Talkeetna to the correlPonding average daily mainstem discharge at Sunshine (USGS gaging station 15292780). ~ Susitna WSEL Measured River Location Date Time (ft)Streamflow Discharge Lower Goose 2 Creek 821001 1145 213.05 137.4 31,500 Gage Site 073.1T2 820929 1610 213.01 33,900 (R.M.73.2;TRM 0.2)820913 1540 213.36 36,400 820830 ,212.85 84.1 39,000 820811 1435 212.89 47,900 820624 1350 212.65 62,700 820713 1630 212.31 63,000 820610 1400 212.71 64,200 820625 1410 212.69 66,700 820915 1120 213.57 68,700 820915 1125 213.77 251.0 68,700 820728 1230 213.01 72,000-,-Lower Goose 2 Slough 821001 1310 210.51 1.8 31,500 (mid-slough)820830 1600 ------10.3 39,000 Gage Site 073.1S4 820915 1325 212.06 458.0 68,700 (R.M.073.1) Lower Goose 2 SlOU 5h 821001 1005 209.25 31,500 {lower portion 820929 1315 209.30 33,900 Gage Site 073.1S1 820913 1410 209.38 36,400 (R.M.73.1)820825 1220 209.25 38,700 820830 1420 209.33 101.0 39,000 ..-820811 1145 209.83 47,900 820810 1120 209.98 51,600 820914 1240 210.17 53,300 820624 1400 210.40 60,800 ~820713 1600 210.26 63,000 820610 1400 210.40 64,200 820611 1615 210.51 65,000 820625 1440 210.64 66,700 820915 1240 210.68 68,700 820915 1600 211.07 68,700 Mainstem adja~ent to Lower 821001 1539 209.10 31,500 Goose 2 Slough 821001 0945 209.12 31,500 Gage Site 073.1M3 820930 1220 209.14 33,400 ~(R.M.073.1)820929 1630 209.14 33,900 820913 1350 209.25 36,400 820830 1030 209.33 39,000 a USGS provisional data,1982. F'4-A-173 4-A-174 F'",'-Appendix Table 4-A-6 (Continued) ""'" Susitna ~WSEL Measured River Location Date Time (ft)Streamflow Discharge Rabideux Creek Mouth -Cont'd 820728 1700 261.71 72 ,000 Gage Site 083.1W1 820918 1120 262.27 76,500 (R.M.83.1;TRM 0.2)820917 1030 263.55 88,400-Sunshine Creek'821007 1300 266.83 21,400 Gage Site 085.7T2 821004 1115 266.93 68.6 25,800 (R.M.85.7;TRM 0.7)820912 1500 266.67 35,000,....820901 1330 267.20 31.8 45,200 820815 1700 266.78 47,900 820805 1810 266.99 44.9 50,400 820712 1510 267.05 60,100-820624 1600 267.61 62,200 820610 1800 267.56 64,200 820625 1025 267.88 66,700-820609 1600 268.28 70,800 820728 1025 268.70 72 ,000 820918 1350 268.91 103.9 76,500,-,820727 1400 269.47 82,400 820916 1815 270.81 91,300 Sunshine Slough 821004 1015 264.55 0.3 25,800-Gage Site 085.7S3 820930 1310 264.58 33,400 (R.M.85.7)820912 1355 264.57 35,000 820824 1347 264.61 38,700,....820901 1353 265.48 85.8 47,200 820815 1650 265.99 47,900 820712 1718 267.01 60,100-820624 1600 267.54 62,200 820713 0940 267.27 63,000 820610 1800 267.52 64,200 820625 1100 267.94 66,700 820609 1600 268.14 70,800 820728 1100 268.64 72 ,000 820918 1448 268.74 607.1 76,500-820727 1630 269.30 82,400 820916 1835 270.80 91,300-Sunshine Creek Mouth 821007 1305 264.19 21,400 Gage Site 085.7Tl 821004 1100 264.25 25,800 (R.M.085.7;TRM 0.0)820930 1305 264.29 33,400 4-A-175 Appendix Table 4-A-6 (Continued) Susitna WSEL Measured River Location Date Time (ft)Streamflow Di scharge - Sunshine Creek Mouth -Cont'd 820901 1220 265.41 47,200 Gage Site 085.7T1 820815 1705 268.18 47,900 (R.M.085.7;TRM 0.0)820805 ------50,400 ~ 820712 1712 264.40 58,400 820713 0935 264.64 60,100 820610 1800 264.81 64,200 820609 1600 265.46 70,800 820728 1020 266.00 72 ,000 820918 1255 268.71 76,500 820727 1630 264.12 82,400 820916 1830 270.70 91,300· Birch Creek 821006 1330 286.08 22,300 ~ Gage Site 088.4T4 .821003 1319 286.10 76.4 27,800 (R.M.089.0;TRM 0.1)820911 1500 285.89 33,800 820928 1430 286.12 35,900 820813 1520 286.00 42,000 820902 1300 285.99 68.2 43,700 820805 1607 285.99 62.4 50,400 820809 1330 285.98 52,500 ~- 820919 1050 286.34 114.1 69,500 820727 1010 286.47 82,400 """I Birch Creek Mouth 821006 1220 284.69 22,300 Gage Site 088.4T3 821003 1230 284.80 27,800 (R.M.089.0;TRM 0.0)820911 1500 284.52 33,800 -820928 1350 284.82 35,900 820813 1525 284.68 42,000 820902 1250 284.71 43,700 820711 1200 284.56 58,400 820702 1200 284.63 59,300 820712 1115 284.59 60,100 820912 1110 285.43 32,500 820727 1010 285.93 82,400 820726 1330 286.61 99,300 Birch Creek Slough (Head)820813 1620 308.90 42,000 - Gage Site 088.Lj.H6 820902 1720 308.17 43,700 (R.M.088.4)820919 1400 310.20 69,500 - ..... 4-A-176 .- ",1~Appendix Table 4-A-6 (Continued) - Susitna WSEL Measured River Location Date Time (ft)Streamflow Discharge Birch Creek Slough 821006 1335 284.75 22,300 (upstream of Birch Creek 821003 1410 284.81 27,800 and slough confluence)820911 1500 284.61 33,800 Gage Site 088.4S1 820928 1400 284.86 35,900 (R.M.089.1)820823 1435 284.56 38,000 820813 1535 284.65 42,000 820902 1240 284.74 15.7 43,700 820805 1700 284.83 50,400 820809 1330 284.84 52,500 820919 1245 285.48 69,500 820727 1030 285.94 82,400 820726 1330 286.61 99,300 Birch Creek Slough 821006 1115 284.63 22,300 (downstream of Birch 821003 1455 284.71 27,800 Creek and slough 820928 1345 284.76 35,900 confluence)820919 1208 285.38 69,500,-Gage Site 088.4S8 (R.M.089.0) Birch Creek Slough 821006 1105 284.36 22,300 (downstream of Birch 821003 1430 284.42 86.5 27,800 Creek and slough 820929 1345 284.50 33,900 confluence)820813 1540 284.33 42,000 Gage Site 088.4S5 820902 1130 284.42 75.4 43,700 (R.M.089.0)820805 1515 284.57 89.3 50,400 820810 1807 284.57 51,600 ""'"820809 1500 284.61 52,500 820919 1140 285.34 131.8 69,500 Birch Creek Slough Mouth 821006 1425 279.36 22,300 Gage Site 088.4W2 821003 1352 279.94 27,800 (R.M.088.4)820911 1500 280.33 33,800 820929 1105 280.45 33,900 820928 1055 280.48 35,000 820912 1150 280.64 35,900 820902 1325 281.08 43,700 820901 1730 281.29 47,200 820711 1635 281.78 58,400 820702 281.68 59,300 820915 1435 282.70 68,700 4-A-177 4-A-178 - ""'" ""'" J "]"--1 1 ) J 1 I ) Appendix Table4,.A-7 Surface area of sggregate type II hydraulic zones at Designated Fish Habitat (DFH)sites and mainstem Susitna River discharges,June throug~september,1982. ~ I>- I...... '-Jc.o Slough 20 Slough 19 Disch§rge Date Zones- 1,900 7/25 6 28,500c 6/19 6 24,000 7/11 none 17,000 8/09 2 13,800 9/27 2 12,500 8/20 2 12,200 9/06 2 33,250c 6/20 7 26,800 7/24 none 23,000 6/04 none 18,100 7/08 none 16,500 8/07 none 14,400 9/04 2 14,000 9/26 none 12,500 8/20 2 24,900 7/23 2 22,000 6/17 2 22,000 6/05 2 16,800 8/06 2 16,600 7/07 2 15,000 9/25 none 14,400 9/04 none 13,300 8/19 2 ~,250c 6/20 2 27,300 7/14 2 23,600 7/29 2 23,000 6/04 2 14,400 8/12 2 12,400 9/29 2 12,200 9/06 2 12,200 8/22 2 20,600 500 1,800 26,000 10,000 16,500 12,300 4,800 4,200 aUSGS provisional data at Gold Creek,1982,15292000. bJune 10,1982,data for Slough 21 incomplete. cAmended mainstem discharge at Gold Creek as determined from ADFC stage discharge curve. Appendix Table 4-A-7 (Continued). Di schgrge Surface Area DFH Site cfs Date Zones .!lEe I I(Ft 2 ) Slough 9b 29,100 7/27 none 28,400 7/13 none 19,400 9/23 2 118,000 16,700 8/10 2 133,000 12,200 8/21 none 11,700 9/07 none Slough 8A 28,000 6/08 6 210,000 26,500c 7/12 2 202,000 26,500 6/23 2 210,000 25,600 7/28 2 205,000 17,100 9/24 2 143,000 15,400 8/11 2 193,000 12,200 8/21 2 158,000 11,700 9/07 2 155,000 Lane Creek 28,500 c 6/19 2 48,200 +>-25,000 6/07 6+7 45,000 I 22,400 7/22 2 14,400:x:- I 18,100 7/08 2 ·14,700......16,600 8/08 2 12,700ex> 0 15,000 9/25 2 8,000 14,400 9/10 2 9,400 12,500 8/20 2 6,100 Slough 6A 33,250c 6/20 2 138,000 24,900 7/23 2 135,000 23,000 6/06 2 131,000 21,500 7/09 2-134,000 16,600 8/08 2 131,000 14,400 9/10 2 129,000 14,000 9/26 2 131,000 12,200 8/21 2 127,000 aUSGS provisional data at Gold Creek,1982,15292000. bJune 10 and June 22 data for Slough 9 incomplete. cAmended mainstem discharge at Gold Creek as determined from ADFG stage discharge curve • .~, J J J J )J _J J I J J J J )J J 1 -J] "-)1 ]I -' }J 1 J ) J Appendix Table 4-A-7 (Continued). DFH Site Whisker Creek and Slough Birch Creek and Slough ~ ~Sunshine Creek and Sidechannel I ~ 00 ~ Discharge Surface Area cfs Date ~Type II (Ft Z ) 37,0009 6/21 7 b76,000b 31,900a 7/25 7 56,000 25,000 6/03 2+7 160,000c 23,000 7/10 7 83,900 16,600 8/08 2 d 4~~600d13,800 9/27 none 13,400 9/09 2 29,200 12,200 8/22 2 28,500 99,300e 7/26 2+6+7 424,000 61,600 6/23 6+7 354,000 59,700 6/04 6+7 359,000 58,400 7/11 6+7 398,000 52,500 8/09 7 157,000 38,000 8/23 2 147,000 35,900 9/28 2 59,500 33,800 9/11 2 81,900 82,400f 7/27 2 242,000 70,200 6/09 2 121,000 62,700 6/24 2 134,000 60,100 7/12 2 178,000f 51,600 8/10 2+6+7 128,000 38,700 8/24 2 46,300 35,000 9/12 2 12,200 33,400 9/30 2 25,300 aUSGS provisional data at Gold Creek 15292000 (with Whisker Creek data). bSurfacearea measure~ents for June 21 and July 25,1982,are lower limits. cSurface area measurement for June 3,1982 is an upper limit. dHigh tributary discharge this date eliminated zone 2 (see text). eUSGS provisional data at Sunshine 15292780. fAn area of HII water assocated with this measurement was not measured (see text). gAmended mainstern discharge at Gold Creek as determined from ADFG stage discharge curve. +:> I ~ J......co--I') Appendix Table 4-A-7 (Continued). DFH Site Rab i deux Creek and Slough b Whitefish SloughC Goose Creek and Sidechannel Di schgrge Surface Area cfs Date Zones .!rP.e II (Ft 2 ) 71,700 6/26 2+7+8 1,160,000 67,900 7/29 2+7 1,180,000 53,000 9/14 2 965.000 44.000 8/12 2 876,000 38,700 8/25 2 836,000 33,400 9/30 2 344,000 72,000 7/28 2 85,800 66,700 6/25 2 75,000 60,100 7/12 2 65,800 53,000 9/14 2 71,000 47,900 8/11 2 56,200 38,700 8/25 2 32.200 33,900 9/29 2 14.200 72,000 7/28 6+7 75.000 66,700 6/25 6+7 83,000 64,200 6/10 6+7 87,000 63.000 7/13 6+7 74.400 47.900 8/11 6+7 113,000 38.700 8/25 6+7 122,000 36,400 9/13 none 33.900 9/29 none aUSGS provisional data at Sunshine,1982,15292780. bNot sampled in early June or in early July. CNot sampled in early July. )\ _J I I J I ,_J .J J _J J _"J J )J J J """ ~, """ ..... APPENDIX 8 SLOUGH AVAILABILITY AND UTILIZATION DATA This appendix includes depths,velocities,and substrate types for Chum Channel,Rabideux Slough and sloughs 8A,9 and 21 that were available to (pp.4-6-2 to 4-B-89)and utilized by (pp.4-B-90 to 4-8-100)chum,pink and sockeye salmon for spawning at various slough discharges.It also contains a complete summary of instantaneous intragravel and surface water temperature data at redds in sloughs 8A,9,11 and 21 (pp.4-B-92 to 4-8-100).Other temperature data for these sloughs,not included in this appendix,are presented in Appendices C and D.Appendix C includes a complete summary of continuous surface and intragravel water temperatures collected with thermographs and datapods in these and other locations.It also includes the instantaneous temperature data included in this Appendix.Instantaneous surface and intragravel water temperature data collected along transects in Sloughs 8A,9,98,11 and 21,and at specified locations in sloughs 8A,9 and 21 are in Appendix D.Mainstem depth and velocity utilization data for eulachon,Bering cisco and chum salmon spawning sites are presented in Appendix F.All of the above data were collected during the open-water season in the study area located within the Cook Inlet·to Devil·Canyon reach of the Sus itna River. 4-8-1 Table 4-S-1.Velocities (ft/sec)and depths (ft)in Chum Channel at three different discharges,1982. t \~,1JIIJJIJIj___J __J j j )J j J J -1 H ]1 j i D J 1 -)!]J J --1 J 1 1)) Tab 1e 4-8-2.Vel od ti es (ft/sec)and depths (ft)in Rabi deux Slough at three di fferent di scha rges,1982. Transect Number Flow (cfs)0 1 2 3 4 5 6 7 0-7 VELOCITIES ~0.00 0.00 0.00 0.00 0.08 0.20 0.01 0.27 0.04x 0.3 Range 0.00-0.00 0.00-0.00 0.00-0.00 0.00-0.00 0.00-0.20 0.10-0.30 0.00-0.10 0.20-0.40 0.00-0.40 N 18 16 7 7 3 7 4 62 x 2.05 0.67 1.26 1.24 1.12 1.19 1.27 1.31 1.28 281 Range 0.05-3.64 -0.39-2.45 -0.05-2.85 0.21-1.86 0.00-1.87 0.00-2.15 0.26-2.20 0.44-242 -0.39-3.64 N 39 49 33 20 25 19 27 228.0 .j:::o I CD DEPTHSIw-x 0.2 1.8 0.3 0.3 0.3 0.6 0.3 0.7. 0.3 Range 0.1-4.3 0.1-2.7 0.1-0.7 0.2-0.3 0.2-0.5 0.6-1.9 0.2-0.3 0.1-4.3 N 18 16 7 7 3 7 4 62 x 281 Range N 4.7 0.2-8.69 69 4.4 0.25-7.4 40 3.2 0.6-5.6 33 3.2 0.8-4.3 20 2.6 0.2-3.65 25 2.7 0.62~3.2 25 2.7 0.5-4.95 19 2.3 0.65-3.82 27 3.4 0.2-8.69 228 Appendix Table 4-B-3.Velocities (ft/sec)and depths (ft)in Slough 8A at three different discharges,1982. Transect Number Flow (cfs)1 2 3 4 5 6 7 8 9 .l.Q 11 1-11- VELOCITIES -0.03 0.05 0.14 0.07 0.11 0.19 0.31 0.08 0.07 0.06 0.05 0.11x 4 Range 0.00-0.10 0.00-0.15 0.00-0.55 0.00-0.10 0.00-0.50 0.00-0.80 0.00-1.50 0.00-0.40 0.00-0~20 0.00-0.150.00-0.200.00-0.80 N 41 33 34 20 32 28 33 30 32 35 23 341 -0.07 0.11 0.15 0.10 0.07 0.27 0.54 0.23 0.15 0.11 0.11 0.17x 7 Range 0.00-0.15 0.00-0.32 0.00-0.62 0.00-0.18 0.00-0.21 0.00;'0.71 0.00-1.78 0.02-0.55 0.00-0.34 0.00-0.24 0.00-0.45 0.00-1.78 N 42 33 35 22 32 28 32 32 32 36 24 348 -0.16 0.23 0.36 0.21 0.17 0.53-0.74 0.53 0;-40 0.29 0.26 0.35x 20 Range 0.00-0.45 0.00-0.80 0.00-1.20 0.00-0.40 0.00-0.400.20-0.90 0.00-2.10 0~00"O.90 0.00;'0.70 0.00-0.70 0.00-0.90 0.00-1.20 .j:::,N 42 34 37 29 33 30 36 39 35 37 29 381I OJ I ~ DEPTHS -1.1 1.2 0.6 1.2 2.4 0.2 0.2 0.2 0.4 0.5 0.5x 0.8 4 Range 0.1-1.65 0.05-1.90 0.2-1.0 0.2-1.9 0.2-4.9 0.05-0.~0.05-0.5 0.05-0.7 0.05-1.05 0.1-1.1 0.5-1.6 0.05-4.9 N 41 33 34 20 33 28 33 36 32 3S 23 348 -1.2 1.3 0.7 1.3 2.5 0.4 0.2 0.3 0.5 0.6 0.6x 0.9 7 Range 0.1-1.9 0.5-2.1 0.05-1.25 0.1-1.9 0.35-4.9 0.1-0.6 0.05-0.6 0.05-0.7 0.05-1.1 0.05-1.15 0.05-1.65 0.05-4.9 N 42 33 37 22 32 28 34 35 32 36 25 356 -1.3 1.4 0.9 1.2 2.6 0.6 0.3 0.4 0.6 0.8 0.7 1.0 x 0.2-1.9 0.25-2.2 0.3-1.4 0.1-2.15 0.6-5.3 0.3-0.8 0.1-0.7 0.1-1.1 0.1-1.2 0.1-1.4 0.1-1.9 0.1-5.3 20 Range 42 35 37 29 33 30 36 39 35 37 29 382 N l ~ I J J }J )I )J ~J ]~-J ]J I j -))J i ))))t 1 .t --]J t »~ ) Table 4-6-4.Velocities (ft/sec)and depths (ft)in Slough 9 at three different discharges,1982. Transect Number Flow (cfs)1 2 4 6 7 8 9 10 1-10 VELOCITIES -0.11 0.15 0.32 0.11 0.06 0.03 0.04 0.05 0.10x 3 Range 0.00-0.30 0.00-0.50 0.00-0.98 0.00-0.22 0.00-0.10 0.00-0.08 0.00-0.10 0.00-0.10 0.00-0.98 N 28 25 26 23 39 28 33 28 230 -0.26 0.30 0.56 0.28 0.15 0.07 0.10 0.07 0.24x 8 Range 0.00-0.59 0.00-0.70 0.00-2.00 0.05-0.42 0.00-0.23 0.00-0.11 0.01-0.19 0.00-0.15 0.00-2.00 N 27 29 40 23 40 28 30 28 245 x 1.06 1.14 1.21 1.27 1.14 1.07 0.97 0.78 1.11 145 Range 0.00-1.63 0.00-1.95 0.00-2.40 0.00-2.35 0.25-1.48 0.00-1.98 0.08-1.58 0.00-1.24 0.00-2.40 N 25 24 36 35 34 18 19 17 208 -1.14 1.43 1.37 1.48 1.15 1.10 1.23 1.24 1.28->::>x I 232 Range 0.00-1.88 0.00-2.60 0.02-2.35 0.02-2.15 0.40-1.60 0.00-1.88 0.00-2.15 0.20-2.04 0.00-2.600::; I N 28 26 40 35 37 21 23 19 229 (Jl DEPTHS x 0.6 0.4 0.1 0.4 0.5 1,6 1.3 1.8 0.8 3 Range 0.1-0.75 0.1-0,7 0.1-0.3 0.1-1.0 O~1-0.8 0.2-2.5 0.1-3.35 0.1-3.65 0.1-3.65 N 28 25 29 23 39 28 33 28 233 x 0.6 0.4 0.1 0.6 0.5 1.7 1.4 2.0 0.9 8 Range 0.1-0.8 0.1-0.7 0.05-0.25 0.05-1.25 0.05-0.9 0.1-2.7 0.05-2.7 0.1-3.7 0.05-3.7 N 28 29 40 24 43 28 31 28 251 x 1.2 1.0 0.7 0.7 0.9 1.9 1.7 2.3 1,2 145 Range 0.3-1,9 0.05-1.8 0.05-1.3 0.05-1.9 0.05-1.4 0.1-3.0 0.1-3.3 0.1-4.0 0.05-4.0 N 25 24 36 35 34 18 19 17 208 -1.4 1.3 1.0 1.2 2.1 2.6 1.4x1.0 1.9 232 Range 0.05-2.1 0.1-2.25 0.1-1,8 0.5-2.3 0.35-1.8 0.1-3.6 0.05-4.6 0.2-4.7 0.05-4.7 N 28 26 40 35 37 21 23 19 229 Table 4-6-5.Velocities (ft/sec)and depths (ft)in Slough 21 at three different discharges,1982, Transect Number Flow (cfs)1 2 3 4 5 6 7 8 1-8- VELOCITIES -0,07 0.21 0.12 0.09 0.24 0.38 0.24 0.06 0.14x 5 Range 0.00-0.20 0.00-1.10 0.00-0.20 0.00-0.30 0.00-0.95 0.00-2.05 0.10-0.35 0.00-0.38 0.00-2.05 N 48 37 31 27 20 18 10 55 246 -0.05 0.11 0.12 0.11 0.24 0.52 0.31 0.20 0.87x 10 Range 0.00-0.15 0.00-0.45 0.00-0.22 0.00-0.23 -0.02-0.61 0.00-2.10 0.00-0.55 0.01-1.50 0.00-2.10 N 32 36 38 32 25 25 13 55 256 -1.29 1.48 0.89 0.93 1.08 1.36 1.59 1.27x 157 Range 0.05-2.45 0.00".3,00 0.10-1.50 0.00-1.45 0.00-1,90 0.00-2.40 0.55-2.50 0.00-3.00 N 88 55 25 18 21 23 15 245 ~ I DEPTHSOJ I Ol x 0.8 0.4 0.8 1.0 0.4 0.2 0.8 0.8 0.7 5 Range 0.05-1.6 0.1-0.85 0.15-1.35 0.2-2.35 0.1-0.7 0.05-0.5 0.1-1.35 0.2-1.8 0.05-2.35 N 48 37 31 27 20 20 12 55 250 -1.4 0.5 1.0 1.1 0.6 0.3 0.9 1.4 1.0x 10 Range 0.2-2.4 0.05-1.1 0.2-1.55 0.15--2.8 0.05-1.1 0.05-0.7 0.1 ..1.65 0.5-2.8 0.05-2.8 N 32 36 38 32 25 26 13 55 257 -2.2 1.5 1.9 2.2 1.4 1 .1 1.3 1.8x 157 Range 0.15-3.8 0.2-2.7 0.5-2.75 0.1-4.0 0.2-2.3 0,3-1.9 0.3-2.5 0.15-4.0 N 88 55 25 18 21.23 15 245 ~<1 I J "J -] )\ __J J J J t J .C"= J .1 J J J Table 4-B-6.Hydraulic habitat variables~collected at transects ln Slough 8A,Aug 22,1982. DEPTH VELOCITY TRANSECT (ft)(ft/s) FLOW SUBSTRATE (cfs)PRIMARY SECONDARY .... - - 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 .40 .80 .90 1.00 1.00 1.00 1.05 1.20 1.30 1.45 1.40 1.50 1.60 1.55 1.60 1.65 1.60 1.60 1.60 1.55 1.50 1.50 ' 1.50 1.40 1.25 1.10 1.00 .95 .95 .95 .85 .90 .80 .85 .80 .60 .65 .50 .45 .30 .10 0.00 .30 .50 0.00 0.00 .10 0.00 0.00 0.00 .05 .05 .05 .03 .10 .10 .05 .05 0.00 .05 .05 .05 .10 .05 .05 .05 .05 .05 .05 0.00 0.00 .05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .05 0.00 0.00 .18 0.00 0.00 0.00 .12 .13 .09 .28 .30 .16 .16 0.00 .17 .16 .16 .32 .16 .15 .15 .15 .14 .13 0.00 0.00 0.00 .10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .05 4-B-7 SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT ,SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT SILT COBBLE SILT ~Table 4-B-6.(Continued). ,."~, ------------------------------------------------------- F""DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft}(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- ~3 .70 0.00 0.00 COBBLE SILT 3 .75 0.00 0.00 COBBLE SILT 3 .80 0.00 0.00 COBBLE SILT 3 .70 0.00 0.00 COBBLE SILT 3 .25 0.00 0.00 COBBLE SILT 3 0.00 0.00 0.00 COBBLE SILT 3 0.00 0.00 0.00 COBBLE SILT 3 .20 0.00 0.00 COBBLE SILT 3 .20 .15 .05 COBBLE SILT 3 .35 .25 .13 COBBLE SILT-3 .45 .35 .24 COBBLE SILT 3 .60 .45 .54 COBBLE SILT 3 .55 .40 .44 COBBLE SILT,-3 .45 .45 .41 COBBLE SILT 3 .50 .55 .44 COBBLE SILT 3 .50 .45 .37 COBBLE SILT 3 .35 .40 .22 COBBLE SILT 3 .30 .40 .19 COBBLE SILT 3 .35 .20 .13 COBBLE SILT 3 .40 .20 .15 COBBLE SILT ~.,~...3 .20 .10 .04 COBBLE SILT 4 .20 0.00 0.00 COBBLE SILT 4 .55 0.00 0.00 COBBLE SILT....4 .95 0.00 0.00 COBBLE SILTIIi41.25 .05 .13 COBBLE SILTI' 4 1.30 .05 .13 COBBLE SILT 4 1.50 .05 .15 COBBLE SILT'f'"4 1.45 .10 .29 COBBLE SILT 4 1.40 .10 .28 COBBLE SILT 4 1.40 .10 .28 COBBLE SILT 4 1.65 .10 .33 COBBLE SILT 4 1.90 .10 .38 COBBLE SILT 4 1.75 .10 .35 COBBLE SILT 4 1.55 .05 1.55 COBBLE SILT 4 1.30 .10 .26 COBBLE SILT 4 1.40 .05 .14 COBBLE SILT 4 1.50 .10 .30 COBBLE SILT 4 1.30 .10 .26 COBBLE SILT 4 1.15 .05 .12 COBBLE SILT 4 .60 0.00 0.00 COBBLE SILT f"""4 .40 0.00 0.00 COBBLE SILT 4 0.00 5 .25 0.00 0.00 SAND SILT 5 1.30 0.00 0.00 SAND SILT 5 2.35 0.00 0.00 SAND SILT ------------------------------------------------------- ~4-B-9 - - .... Table 4-B-6.(Continued). ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ~" TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ~------------------------------------------------------- 7 .20 .05 .02 COBBLE RUBBLE 7 .05 0.00 0.00 COBBLE RUBBLE -7 .10 0.00 0.00 COBBLE RUBBLE 7 .05 0.00 0.00 COB~LE RUBBLE 7 0.00 0.00 ~ 8 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 .20 0.00 0.00 COBBLE RUBBLE 8 .20 0.00 0.00 COBBLE RUBBLE " 8 .10 0.00 0.00 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 .10 0.00 0.00 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 .10 0.00 0.00 COBBLE RUBBLE' 8 .10 .10 .02 COBBLE RUBBLE ~ 8 0.00 0.00 0.0,0 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 0.00 0.00 0.00 COBBLE RUBBLE 8 .10 ~25 .05 COBBLE RUBBLE _. 8 0.00 0.00 0.00 COBBLE RUBBLE 8 0.00 0.00 0.00 COBBLE RUBBLE 8 0.00 0.00 0.0.0 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 0.00 0.00 O~QO COBBLE RUBBLE 8 .10 .05 .01 COBBLE RUBBLE 8 .05 0.0,0 0.00 COBBLE RUBBLE 8 .20 0.00 .04 .COBBLE RUBBLE 8 .40 0.00 .16 COBBLE RUBBLE 8 .50 0.00 .30 COBBLE'RUBBLE ~ 8 .55 0.00 .l3 COBBLE RUBBLE 8 .65 0.00 .39 COBBLE RUBBLE 8 .70 .40 .56 COBBLE RUBBLE -.8 .55 •40 .44 COBBLE RUBBLE 8 .40 .30 .24 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 .30 .15 .09 COBBLE RUBBLE 8 .30 .30 .18 COBBLE RUBBLE 8 .20 •.20 .08 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE 8 .05 .05 .01 COBBLE RU~BLE 8 .10 0.00 0.00 COBBLE RUBBLE 8 .05 0.00 0.00 COBBLE RUBBLE ~, 9 .10 0.00 0.00 COBBLE GRAVEL 9 .05 0.00 0.00 COBBLE GRAVEL 9 .05 0.00 0.00 COBBLE GRAVEL -------------------------------------------------------- 4-B-12 _. - ,.... Table 4-B-6.(Continued). ;~~, -----------------~------------------------------------- "...DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(fti s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- 9 0.00 0.00 0.00 COBBLE GRAVEL 9 .05 0.00 0.00 COBBLE RUBBLE 9 .10 0.00 0.00 COBBLE RUBBLE-.059.25 .10 COBBLE RUBBLE 9 .30 .10 .06 COBBLE RUBBLE 9 .30 .10 .06 COBBLE RUBBLE A 9 .30 .10 .06 COBBLE RUBBLE 9 .35 .05 .04 COBBLE RUBBLE 9 .45 .10 .09 .COBBLE RUBBLE ~lll 9 .10 0.00 0.00 COBBLE RUBBLE 9 .20 0.00 0.00 COBBLE RUBBLE 9 .20 .05 .02 COBBLE RUBBLE 9 .25 .10 .05 COBBLE RUBBLE ~.9 .40 .15 .12 COBBLE RUBBLE 9 .60 .20 .24 COBBLE RUBBLE 9 .65 .20 .26 COBBLE RUBBLE ~9 1.05 .15 .32 COBBLE RUBBLE 9 1.00 .20 .40 COBBLE RUBBLE 9 .95 .15 .29 COBBLE RUBBLE,--9 .90 .15 .27 COBBLE RUBBLE 9 .55 ..15 .17 COBBLE RUBBLE 9 .40 .15 .12 COBBLE RUBBLE 9 .25 .10 .05 COBBLE RUBBLE 9 .10 0.00 0.00 COBBLE RUBBLE 9 .50 .05 .05 COBBLE RUBBLE 9 .40 .05 004 COBBLE RUBBLE-9 .30 .05 .03 COBBLE RUBBLE 9 .20 0.00 0.00 COBBLE RUBBLE 9 .10 0.00 0.00 COBBLE RUBBLE 9 0.00 10 .20 COBBLE RUBBLE 10 .35 0.00 0.00 COBBLE RUBBLE 10 .20 0.00 0.00 COBBLE RUBBLE """10 .20 0.00 0.00 COBBLE RUBBLE 10 .20 0.00 0.00 COBBLE RUBBLE 10 .35 .05 .04 COBBLE RUBBLE 10 .40 .05 .04 COBBLE RUBBLE 10 .40 .05 .04 COBBLE RUBBLE 10 .55 .10 .11 COBBLE RUBBLE 10 .80 .10 .16 COBBLE RUBBLE 10 .50 0.00 0.00 SILT GRAVEL 10 .45 0.00 0.00 SILT GRAVEL 10 .30 .0.00 0.00 SILT GRAVEL 10 .40 .05 .04 SILT GRAVEL 10 .55 .05 .06 SILT GRAVEL ------------------------------------------------------- 4-B-13 """ Table 4-B-6.(Continued).-------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ;"J'IJ' TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ~, ~------------------------------------~----------------- 10 .40 .05 .04 SILT GRAVEL 10 .45 .10 .09 SILT GRAVEL 10 .50 .05 .05 SILT GRAVEL 10 .50 .10 .01 SILT GRAVEL 10 .60 .10 .12 SILT GRAVEL ~ 10 .70 .15 .21 SILT GRAVEL 10 .80 .15 .24 SILT GRAVEL 10 .80 .15 .24 RUBBLE SILT 10 1.10 .15 .33 SILT -RUBBLE 10 1.10 .15 ..33 RUBBLE SILT 10 1.00 .15 .30 RUBBLE SILT 10 1.00 .10 .20 RUBBLE SILT ~ 10 .75 .10 .15 RUBBLE SILT 10 .85 .10 .17 RUBBLE SILT 10 .65 .05 .06 RUBBLE SILT -.10 .20 0.00 0.00 RUBBLE SILT 10 .25 0.00 0.00 RUBBLE SILT 10 .30 0.00 0.00 RUBBLE SILT 10 .20 0.00 0.00 RUBBLE SILT """', ! 10 .10 0.00 0.00 RUBBLE SILT 11 .05 0.00 0.00 COBBLE 11 .30 0.00 0.00 COBBLE """",.- 11 0.00 0.00 0.00 COBBLE 11 0.00 0.00 0.00 COBBLE 11 .35 0.00 0.00 COB.BLE -11 .10 0.00 0.00 COBBLE 11 0.00 0.00 0.00 COBBLE 11 0.00 0.00 0.00 COBBLE SILT 11 0.00 0.00 0.00 COBBLE SILT .- 11 .05 0.00 0.00 COBBLE SILT 11 .20 0.00 0.00 SAND 11 0.00 0.00 0.0,0 SAND 11 .05 0.00 0.00 COBBLE SILT 11 .05 0.00 0.00 COBBLE SILT 11 0.00 0.00 0.00 SAND 11 .10 0.00 0.00 SAND 11 .30 0.00 0.00 SAND 11 .50 .05 .05 COBBLE SAND 11 1.00 .05 .10 COBBLE SAND -, 11 1.00 .05 .10 COBBLE SAND 11 1.05 .10 .21 COBBLE SAND 11 1.60 •.15 .48 COBBLE SAND ...... 11 1.40 .20 .56 COBBLE SAND 11 1.35 .20 .54 COBBLE SAND 11 1.05 .10 .21 COBBLE SAND ._, ----~-------------------~-----~----------------------~~,4-B-14 - Table t~-R-6.<Continued). DEPTH VELOCITY TRANSECT (ft)(ft/s) FLOW SUBSTRATE (cfs)PRIMARY SECONDARY 11 11 11 11 .90 .60 .10 0.00 .10 .05 0.00 0.00 .18 .06 0.00 0.00 COBBLE COBBLE COBBLE COBBLE SAND SAND SAND SAND - - - - - ~/Summarized in Appendix Table 4-B-3. 4-B-15 Table 4-B-1.Hydraulic habitat variables collected at transects 10 Slough 8A,Aug 26.1982.- ------------------------------------~-------~-~-------- ~" DEPTH VELOCITY TRANSECT (ft)(ft/s) FLOW SUBSTRATE (cfs)PRIMARY SECONDARY ----------------'-------_._------------------------------ 4-B-16 - - - -I -- RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE R:UBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE RUBBLE GRAVEL GRAVEL GRAVEL GRAVEL GRAVEL 0.00 0.00 .14 .19 .21 0.00 .16 .16 .92 .49 •.49 .66 .46 •.88 .16 .10 .43 .43 1•.12 0.00 .11 .24 .24 .22 0.00 .08 0.00 .06 .07 O.GO 0.00 0.00 0.00. O.frO 0.00 .07' 0.00 0.00 0.00 1.00 .12 0.0.0 0.00 0.00 0.00 .05 .05 .05 0.00 .02 .02 .10 .05 .05 .07 .05 .10 .02 .10' .Q7 .07 .20 0.00 .02 .05 .05 .05 O.QO .02 0.00 .02 .02 0.00 0.00 0.00 0.00 0.00 0.00 .02 0.00 0.00 0.00 .02 .02 0.00 0.00 0.00 .10 .30 .10 .95 1.05 1.80 2.00 2.00 2.30 2.45 2.45 2.35 2.30 2.20 2.00 1.75 1.55 1.55 1.40 1.40 1.40 1.20 1.20 1.10 1.00 1.00 1.00 .08 .85 .10 .70 .60 .70 .70 < .85 .90 .80 .95 1.10 1.20 1.50 1.80 0.00 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A --------~---------------~~----------~----------~.---- Table 4-B-7.-(Continued). i~" ------------------------------------------------------- r""DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- i!""" B 0.00 0.00 B .10 .15 .03 COBBLE RUBBLE B .30 0.00 0.00 COBBLE RUBBLE ""'"'B .20 .75 .30 COBBLE RUBBLE B .40 .05 .04 COBBLE RUBBLE B .30 .50 .30 COBBLE RUBBLE r"""B .20 .15 .06 COBBLE RUBBLE B 0.00 0.00 0.00 B .15 .60 .18 COBBLE RUBBLE-B .05 0.00 BOULDER RUBBLE B .40 .80 .64 RUBBLE GRAVEL C 0.00 0.00 SILT COBBLE C .15 0.00 0.00 SILT COBBLE..-C .50 .05 .05 RUBBLE COBBLE C .70 .10 .14 RUBBLE GRAVEL C .50 .15 .15 RUBBLE GRAVEL !"""C .65 .20 .26 'RUBBLE GRAVEL C .75 .20 .30 RUBBLE GRAVEL C .55 .10 .11 RUBBLE GRAVEL C .60 .15 .18 GRAVEL RUBBLE C .55 .10 .11 GRAVEL RUBBLE C .55 .15 .17 GRAVEL RUBBLE C .35 .15 .11 COBBLE RUBBLE C .35 .10 .07 RUBBLE COBBLE C .30 .05 .03 RUBBLE GRAVEL C .20 0.00 0.00 RUBBLE GRAVEL C .10 0.00 0.00 RUBBLE GRAVEL C 1.00 0.00 ------------------------------------------------------- - 4-B-17 - Table 4-B-8.Hydraulic habitat variab1es~/collected at transects 1n Slough 8A,Sep 07 ,1982. -,,"------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- 1 .65 .03 .02 SAND ""'" 1 1.00 .09 .18 SAND 1 1.10 .09 .20 SAND COBBLE 1 1.10 .05 .ll SAND ~ 1 1.15 .10 .23 SAND 1 1.20 .10 .24 SAND 1 1.20 .10 .24 SAND 1 1.40 .05 .14 SAND ~ 1 1.65 .08 .26 SAND 1 1.65 .08 .26 SAND 1 1.65 .05 .17 SAND -1 1.65 .01 .03 SAND 1 1.70 .08 .27 SAND 1 1.75 .08 .28 SAND 1 1.75 .08 .28 SAND 1 1.80 .08 .29 SAND 1 1.90 .11 .42 SAND 1 1.85 .10 .37 SAND 1 1.75 .12 .42 SAND 1 1.10 .15 .51 SAND 1 1.70 .15 .51 SAND ~,- 1 1.65 .15 .50 SAND 1 1.50 .15 .45 SAND 1 1.50 .11 .33 SAND ..... 1 1.35 .11 •30 SAND 1 1.30 .11 .29 SAND 1 1.25 .11 .28 SAND 1 1.15 .10 .23 SAND -1 1.10 .10 .22 SAND 1 1.05 .11 .23 SAND 1 1.00 .05 .10 SAND 1 1.00 .02 .04 SAND 1 1.00 .01 ..02 SAND 1 1.00 0.00 0.00 SAND "'"'I1.90 .01 .02 SAND 1 .80 .01 .02 SAND 1 .80 0.00 0.00 SAND 1 .60 .02 .02 SAND -1 .50 .03 .03 SAND 1 .40 0.00 0.00 SAND 1 .30 .01 .01 SAND -1 .10 0.00 0.00 SAND 2 .50 .12 .11 COBBLE SILT 2 .60 .20 .24 COBBLE SILT - ~------------------------------------------------------~'"4-B-18 PifiM Table 4-B-8.(Continued). ~. ------~--~--------------------------------------------DEPTH yELOCITY FLOW SUBSTRATE ,-F TRANSECT (ft>(ft/s)(cfs)PRIMARY SECONDARY ""'"------------------------------------------------------- 3 .95 0.00 0.00 SILT COBBLE 3 .90 .04 •01 SILT COBBLE ..... 3 .85 .02 .03 SILT COBBLE 3 .80 .01 .02 SILT COBBLE 3 .40 0.00 0.00 COBBLE SILT 3 .10 0.00 0.00 COBBLE SILT 3 .05 0.00·COBBLE SILT 3 .05 0.00 COBBLE SILT 3 .15 -0.00 0.00 RUBBLE SILT 3 .10 0.00 0.00 RUBBLE COBBLE ·3 .10 0.00 0.00 COBBLE RUBBLE 3 .20 .01 .04 RUBBLE COBBLE 3 .50 .15 .15 COB~LE RUBBLE 3 .60 .25 .30 RUBBLE COBBLE 3 .70 .28 ..39 RUBBLE COBBLE -3 .60 .55 .66 COBBLE GRAVEL 3 .70 .51 .71 RUBBLE COBBLE 3 .70 .45 .63 COBBLE RUBBLE 3 .70 .39 .55 GlU\VEL COBBLE -3 .70 .48 ~68 RUBBLE GRAVEL 3 .60 .62 .74 GRAVEL COBBLE 3 .55 .32 .35 GRAVEL COBBLE --3 .45 .11 1.00'COBBLE RUBBLE 3 .40 .42 .34 RUBBLE COBBLE 4 .10 .0.00 0.00 RUBBLE COBBLE ~ 4 .30 .01 .01 RUBBLE COBBLE 4 .55 .01 .01 RUBBLE BOULDER 4 .75 .05 .01 RUBBLE COBBLE 4 1.20 .10 .24 COBBLE RUBBLE 4 1.40 .10 .28 COBBLE 4 1.50 .08 .24 BOULDER RUBBLE 4 1.65 .10 .33 COBBLE RUBBLE -4 1.50 .1 ~.36 COBBLE RUBBLE 4 1.60 .11 .35 RUBBLE COBBLE 4 1.65 .15 .50 RUBBLE COBBLE 4 1.90 .14 .53 RUBBLE COBBLE 4 1.90 .15 .57 BOULDER COBBLE 4 1.90 .12 .46 BOULDER COBBLE 4 1.80 .15 .54 BOULDER COBBLE ~ 4 1.60 .15 .48 ·BOULDER COBBLE 4 1.60 .17 .54 BOULDER COBBLE 4 1.55 .18 .56 COBBLE RUBBLE 4 1.50 .10 .30 RUBBLE 4 1.20 .10 .24 BOULDER RUBBLE; 4 .85 .10 .17 RUBBLE -------------------------~----~-~--~-------------------4-B-20 - ~Table 4-B-8.(Continued). e~,- ------------------------------------------------------- """DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY --------------------------------------------------------7 RUBBLE GRAVEL 7 .10 0.00 0.00 RUBBLE GRAVEL 7 .20 .20 .08 GRAVEL RUBBLE-7 .10 .10 .02 GRAVEL RUBBLE 7 .20 .20 .08 GRAVEL COBBLE 7 .15 .10 .03 RUBBLE I~8 .20 .27 .11 GRAVEL RUBBLE 8 .30 .25 .06 GRAVEL RUBBLE 8 .20 .20 .04 RUBBLE GRAVEL 8 .20 .20 .07 GRAVEL RUBBLE ~8 .20 .15 .06 GRAVEL RUBBLE 8 .10 .05 .01 RUBBLE GRAVEL 8 .20 .14 .06 GRAVEL RUBBLE 8 .15 .10 .03 RUBBLE GRAVEL 8 .10 .02 0.00 GRAVEL RUBBLE 8 .05 GRAVEL RUBBLE 8 .10 .20 .02 RUBBLE 8 .20 .20 .08 GRAVEL RUBBLE 8 .15 .25 .04 GRAVEL RUBBLE 8 .05 GRAVEL RUBBLE,,- 8 .05 GRAVEL RUBBLE 8 .10 .15 .03 GRAVEL RUBBLE 8 .15 .10 .03 GRAVEL RUBBLE !-8 .15 .15 .05 GRAVEL RUBBLE 8 .15 .05 .02 GRAVEL RUBBLE 8 .30 .08 .05 RUBBLE COBBLE-8 .45 .20 .~8 GRAVEL RUBBLE 8 .50 .40 .40 RUBBLE GRAVEL 8 .50 .49 .49 GRAVEL 8 .60 .50 .60 RUBBLE SAND ""'"8 .65 .50 .65 RUBBLE COBBLE 8 .70 .55 .77 RUBBLE GRAVEL 8 .50 .50 .50 RUBBLE GRAVEL 8 .60 .35 .42 GRAVEL BOULDER 8 .25 .35 .18 RUBBLE BOULDER 8 .40 .25 .20 RUBBLE BOULDER-8 .30 .35 .21 RUBBLE BOULDER 8 .15 .13 .04 GRAVEL COBBLE 8 .15 .15 .05 GRAVEL COBBLE 8 .20 .05 .02 GRAVEL RUBBLE-8 .15 .08 .02 GRAVEL COBBLE 9 .05 0.00 0.00 GRAVEL COBBLE 9 .10 0.00 0.00 GRAVEL 9 .15 0.00 0.00 GRAVEL RUBBLE 9 .10 0.00 0.00 GRAVEL RUBBLE ------------------------------------------------------- ~4-B-23 "' Table 4-B-8.<Continued). ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ~. TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY --~-------------~------------~-------------------------~ 9 .10 0.00 0.00 GRAVEL RUBBLE 9 .10 0.00 0.00 GRAVEL RUBBLE 9 .30 .10 .06 GRAVEL RUBBLE 9 .40 .18 .14 GRAVEL COBBLE 9 .40 .10 .08 GRAVEL .COBBLE 9 .50 .15 .15 RUBBLE COBBLE 9 .40 .15 .12 COBBLE GRAVEL 9 .50 .12 .12 COBBLE GRAVEL 9 .50 .15 .15 COBBLE GRAVEL .- 9 .40 .10 .08 GRAVEL COBBLE 9 .35 .18 .13 COBBLE RUBBLE 9 .35 .18 .13 RUBBLE 9 .40 .20 .16 RUBBLE BOULDER 9 .40 .28 .22 RUBBLE BOULDER 9 .60 .30 .36 BOULDER RUBBLE 9 .95 .25 .48 GRAVEL.COBBLE .", 9 1.10 .30 .66 SAND RUBBLE 9 1.10 .34 •75 RUB.BLE COBBLE 9 .90 .30 .54 GRAVEL BOULDER -9 .75 .20 .30 RUBBLE COBBLE 9 .80 .20 .32 GRAVEL COBBLE 9 .65 .20 .26 GRAVEL COBBLE ~.-9 .50 .15 .15 COBBLE RUBBLE 9 .30 .20 .12 COBBLE 9 .60 .10 .12 BOULDER RUBBLE 9 .60 .13 .16 RUBBLE COBBLE 9 .50 .10 .10 GRAVEL RUBBLE 9 .40 .15 .12 COBBLE RUBBLE 9 0.00 0.00 0.00 COBBLE BOULDER .- 10 .30 0.00 0.00 SILT 10 .30 .05 .03 SILT GRAVEL 10 .40 .02 .02 COBBLE RUBBLE """"10 .30 .01 .01 GRAVEL RUBBLE 10 .40 0.00 0.00 GRAVEL RUBBLE 10 .40 .05 .04 GRAVEL COBBLE 10 .50 .05 .05 .GRAVEL SILT 10 .50 .10 .•10 RUBBLE GRAVEL 10 .65 .08 .10 RUBBLE GRAVEL 10 •70 .04 .06 RUBBLE BOULDER -10 .60 .04 .05 GRAVEL COBBLE 10 .60 .04 .05 GRAVEL BOULDER 10 .30 0.00 0.00 GRAVEL BOULDER -10 .30 .01 .01 GRAVEL SAND 10 .50 .01 .01 SAND GRAVEL 10 .60 .09 .11 SAND GRAVEL --------------------~~--------------------------------4-B-24 1"'''''. Table 4-B-8.(Continued). ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(£tIs)(cfs)PRIMARY SECONDARY ------------------------------------------------------- 10 .50 .11 .11 SAND GRAVEL 10 .60 .12 .14 SAND RUBBLE 10 .60 .12 .14 SAND RUBBLE,.......10 .70 .20 .28 SAND 10 .80 .22 .35 SAND 10 .95 .20 .38 SAND RUBBLE 1-10 1.00 .20 .40 RUBBLE COBBLE 10 1.15 .20 .46 COBBLE SAND 10 1.15 .20 .46 RUBBLE COBBLE 10 1.45 .22 .51 RUBBLE COBBLE 10 1.10 .21 .46 RUBBLE COBBLE 10 .90 .24 .43 RUBBLE COBBLE 10 1.00 .20 .40 RUBBLE BOULDER 10 .70 .20 .28 RUBBLE COBBLE 10 .60 .12 .14 RUBBLE COBBLE 10 .60 .18 .22 RUBBLE COBBLE 10 .45 .10 .09 RUBBLE COBBLE 10 .35 0.00 0.00 RUBBLE COBBLE 10 .30 .03 .18 RUBBLE COBBLE 10 .05 0.00 0.00 RUBBLE COBBLE ~-,~11 .05 0.00 0.00 COBBLE RUBBLE 11 .10 0.00 0.00 COBBLE 11 .40 0.00 0.00 COBBLE RUBBLE -.11 0.00 0.00 0.00 COBBLE 11 .45 0.00 0.00 COBBLE 11 .45 0.00 0.00 GRAVEL COBBLE,-11 .35 0.00 0.00 RUBBLE COBBLE 11 .15 0.00 0.00 RUBBLE 11 .20 0.00 0.00 RUBBLE SILT 11 .20 0.00 0.00 COBBLE SILT ~11 .25 0.00 0.00 SILT RUBBLE 11 .25 .03 .02 SAND RUBBLE 11 :10 0.00 0.00 SAND 11 .20 .01 0.00 SAND 11 .45 .08 .07 SAND 11 .80 .10 .16 COBBLE SAND 11 1.15 .10 .23 RUBBLE SAND 11 1.30 .20 .52 SAND COBBLE 11 1.60 .28 .90 RUBBLE SAND 11 1.65 .34 1.12 COBBLE BOULDER 11 1.45 .45 1.31 GRAVEL COBBLE 11 1.40 .30 .84 RUBBLE COBBLE 11 1.15 .29 .67 COBBLE RUBBLE r"'"11 1.05 .22 .46 RUBBLE COBBLE 11 •70 .20 .28 RUB.BLE GRAVEL -------------------------------------------------------,....4-B-25 - - ""'"Table 4-B-8.(Continued). ~~------------------------------------------------------- r-DEPTH VELOCITY FLOW SUBSTRATE TRANSECT <ft)(ft/s)(cfs)PRIMARY SECONDARY -------------------------------------------~----------- B .40 .90 .72 GRAVEL RUBBLE B .30 .40 .24 RUBBLE COBBLE B .30 1.35 .71 COBBLE RUBBLE B .30 1.00 .45 COBBLE RUBBLE B .30 1.05 .61 RUBBLE COBBLE B .35 .60 .38 GRAVEL RUBBLE ~B .40 1.15 .92 GRAVEL COBBLE B .30 .40 .18 GRAVEL COBBLE C .10 0.00 0.00 SAND COBBLE C .40 .15 .12 GRAVEL SAND C .50 .20 .20 GRAVEL C .50 .20 .20 GRAVEL RUBBLE C .65 .25 .33 GRAVEL RUBBLE C .80 .22 .35 GRAVEL RUBBLE C .55 .20 .22 RUBBLE GRAVEL C .60 .18 .22 RUBBLE GRAVEL C .70 .19 .27 GRAVEL RUBBLE~C .70 .18 .25 GRAVEL COBBLE C .45 .16 .14 COBBLE SAND C .50 .10 .10 GRAVEL SAND J!"""...o>_C .40 .10 .08 RUBBLE COBBLE C .35 .10 .01 GRAVEL RUBBLE C .35 0.00 0.00 GRAVEL COBBLE C .30 0.00 0.00 GRAVEL SAND C .25 0.00 0.00 GRAVEL SAND C .35 0.00 0.00 GRAVEL SAND ------------------------------------------------------- !./SU1l1lI1 ar ized in Appendix Table 4-B-3. ..... -, 4-B-21 - ,..., Table 4-B-9.Hydraulic habitat variables~/collected at transects in Slough BA.Sep 19.1982."""" ,4!1.'------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- 1 .70 0.00 0.00 SILT 1 1.05 0.00 0.00 SILT 1 1.20 0.00 0.00 SILT 1 1.20 .05 .12 SILT 1 1.30 .05 .13 SILT 1 1.30 .10 .26 SILT 1 1.40 .10 .28 'SILT 1 1.40 .10 .28 SILT -1 1.50 .10 .30 SILT COBBLE 1 1.70 .10 .34 SILT COBBLE 1 1.70 .10 .34 SILT 1 1.65 .10 .33 SILT COBBLE 1 1.80 .10 .36 SILT COBBLE 1 1.80 .10 .36 SILT 1 1.90 .20 .76 SILT 1 1.80 .20 .72 SILT 1 1.85 .30 1.11 SILT 1 1.90 .20 .76 SILT 1 1.90 .35 1.33 SlLT 1 1.80 .30 l.08 SILT 1 1.80 .40 1.44 SILT -""'"1 1.70 .45 1.53 SILT COBBLE 1 1.75 .3'0 1.05 SILT COBBLE 1 1.65 .30 ..99 SILT COBBLE -1 1.50 .35 l.05 SILT COBBLE 1 1.35 .30 .81 SILT COBBLE 1 1.30 .25 .65 SILT RUBBLE 1 1.30 .20 ..52 SILT RUBBLE 1 1.30 .20 .52 SILT RUBBLE 1 1.30 .20 .52 SILT RUBBLE 1 1.10 .20 .44 SILT GRAVEL 1 1.10 .15 .33 SILT GRAVEL 1 1.10 .15 .33 SILT GRAVEL 1 1.00 .10 .20 SILT GRAVEL 1 1.00 .10 .20 SILT GRAVEL 1 .90 .1.'0 .18 SILT GRAYEL 1 1.00 .10 .20 SILT 1 .80 .10 .16 SILT 1 .65 .05 .07 SILT 1 .60 0.00 0.00 SILT 1 .40 0.00 0.00 SILT 1 .20 0.00 0.00 SILT 1 SILT 2 .60 .15 .18 SILT COBBLE -, ---------------------------------------------.---.---- 4-B-28 ~ I"'"Table 4-B-9.(Continued).,,---------------------------------------------------------DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft )(ft/s)(ds)PRIMARY SECONDARY --------------------------------------------------------2 .80 .20 .32 SILT COBBLE 2 .80 .25 .40 SILT COBBLE 2 .80 .20 .32 COBBLE-2 .70 .25 .35 COBBLE 2 .65 .30 .39 COBBLE 2 .60 .50 .60 COBBLE 2 .80 .50 .80 COBBLE 2 1.10 .50 1.10 COBBLE 2 1.50 .60 1.80 COBBLE 2 1.70 .70 2.38 RUBBLE-2 1.70 .80 2.72 RUBBLE 2 1.90 .75 2.85 SILT RUBBLE 2 1.80 .70 2.52 SILT RUBBLE 2 1.80 .45 1.62 SILT 2 1.90 .35 1.33 SILT 2 1.90 .05 .19 SILT RUBBLE 2 2.10 .20 .84 SILT 2 2.20 .05 .22 SILT 2 2.10 0.00 0.00 SILT 2 2.00 .10 .40 SILT RUBBLE ~,-2 1.90 0.00 0.00 SILT RUBBLE 2 1.90 0.00 0.00 SILT RUBBLE 2 1.70 0.00 0.00 SILT RUBBLE 2 1.60 0.00 0.00 SILT 2 1.50 0.00 0.00 SILT 2 1.50 0.00 0.00 SILT 2 1.30 0.00 0.00 SILT 2 1.40 0.00 0.00 SILT 2 1.30 .10 .26 SILT 2 1.30 .10 .26 SILT 2 1.20 .05 .12 SILT 2 1.00 0.00 0.00 SILT 2 .25 0.00 0.00 SILT 1""".3 .90 0.00 0.00 -SILT COBBLE 3 1.00 .20 .40 SILT COBBLE 3 1.20 .15 .36 SILT RUBBLE 3 1.20 .20 .48 SILT COBBLE 3 1.40 .20 .56 SILT RUBBLE 3 1.30 .20 .52 SILT 3 1.20 .20 .78 SILT 3 1.20 .15 .36 SILT RUBBLE 3 1.20 .15 .36 SILT RUBBLE 3 1.10 0.00 0.00 SILT RUBBLE 3 1.10 0.00 0.00 SILT RUBBLE 3 1.10 0.00 0.00 SILT RUBBLE -------------------------------------------------------I"""4-B-29 ~ r-Table 4-B-9.(Continued). 'I~ -------------------------------------------------------,...DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft )(ft/s)(cfs)PRIMARY SECONDARY -~---------------------------------------------------- 4 2.15 .40 1.72 RUBBLE SILT 4 2.00 .40 1.60 RUBBLE SILT 4 1.60 .40 1.28 RUBBLE SILT 4 1.80 .30 1.08 RUBBLE SILT 4 1.90 .30 1.14 SILT RUBBLE 4 1.60 .35 1.12 SILT RUBBLE ~4 1.50 .40 1.20 SILT RUBBLE 4 1.10 .30 .66 SILT RUBBLE 4 .90 .35 .63 SILT RUBBLE 4 .80 .10 .16 SILT RUBBLE 5 .65 0.00 0.00 SAND 5 1.60 0.00 0.00 SAND 5 2.30 0.00 0.00 SAND 5 3.70 0.00 0.00 SAND 5 4.50 0.00 0.00 SAND 5 4.70 0.00 0.00 SAND 5 4.80 0.00 0.00 GRAVEL RUBBLE 5 5.00 .01 .10 GRAVEL RUBBLE 5 5.20 .03 .31 GRAVEL RUBBLE 5 5.30 .13 1.38 GRAVEL RUBBLE,-.,-'5 5.00 .18 1.80 GRAVEL SAND 5 4.60 .20 1.84 GRAVEL SAND 5 4.30 .32 2.72 GRAVEL RUBBLE 5 3.90 .25 1.95 GRAVEL RUBBLE 5 3.60 .25 L80 SILT RUBBLE 5 3.40 .20 1.36 SILT .RUBBLE 5 2.50 .20 1.00 SILT RUBBLE 5 2.20 .25 1.10 SILT RUBBLE 5 1.90 .20 .76 SILT RUBBLE 5 1.70 .30 1.02 SILT RUBBLE 5 1.90 .40 1.52 SILT RUBBLE 5 2.00 .35 L40 SILT RUBBLE 5 1.80 .40 1.44 SILT RUBBLE 5 1.50 .20 .60 SILT RUBBLE 5 L20 .30 .72 SILT RUBBLE 5 1.10 .35 .77 SILT RUBBLE 5 1.10 .20 .44 SILT RUBBLE ~5 1.00 .30 .60 SILT RUBBLE 5 .70 .20 .28 SILT COBBLE 5 .70 .20 .28 SILT RUBBLE,-5 LOO .10 .20 SILT RUBBLE 5 .60 0.00 0.00 SILT RUBBLE 6 .50 0.00 0.00 SILT RUBBLE -.6 .50 .30 .30 SILT RUBBLE 6 .50 .25 .25 SILT RUBBLE ---------------------------------~---------------------4-B-31 ..... Table 4-B-9.(Continued).-------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ~.. TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY --~----------------------------------------------------I""i'; 6 .40 .20 .16 SILT RUBBLE 6 .65 .35 .46 RUBBLE .... 6 •70 .30 .42 SILT RUBBLE 6 .70 .30 .42 SILT RUBBLE 6 .70 .50 .70 RUBBLE SILT -6 .50 .50 .50 RUBBLE SILT 6 .60 .60 .72 RUBBLE SILT 6 .70 .50 .70 RUBBLE SILT 6 .65 .60 .78 RUBBLE SILT -6 .60 .70 .84 RUBBLE SILT 6 .60 .70 .84 RUBBLE SILT 6 .70 .50 .70 RUBBLE SILT 6 .80 .60 .96 RUBBLE SILT 6 .80 .65 1.04 RUBBLE SILT 6 .80 .45 .72 RUBBLE SILT 6 .80 .75 1.20 RUBBLE 6 .80 .90 1.44 RUBBLE SILT 6 .80 .90 1.44 RUBBLE SILT 6 .70 .80 1.12 RUBBLE -, 6 .50 .60 .60 RUBBLE SILT 6 .50 .80 .80 RUBBLE SILT 6 .50 .50 ~50 RUBBLE SILT ~..... 6 •50 .80 .80 RUBBLE SILT 6 .50 .70 .70 RUBBLE SILT 6 .50 .50 .50 COBBLE SILT 6 .50 .40 .40 RUBBLE SILT 6 .30 .30 .18 COBBLE SILT 7 .10 0.00 0.00 RUBBLE SILT 7 .20 0.00 0.00 RUBBLE SILT -, 7 .50 .20 .20 RUBBLE SILT 7 .70 .70 .98 RUBBLE SILT 7 .50 .90 .90 RUBBLE .-, 7 .20 1.00 .40 RUBBLE 7 .30 1.15 .69 RUBBLE 7 .30 .95 .57 RUBBLE 7 .20 1.40 .56 RUBBLE -7 .30 1.20 .72 RUBBLE 7 .40 .40 .32 RUBBLE 7 .40 .30 .24 RUBBLE -7 .30 .60 .36 RUBBLE 7 .30 1.40 .84 RUBBLE 7 .50 .90 .90 COBBLE 7 .60 .60 .72 RUBBLE 7 .60 1.10 1.32 RUBBLE 7 .60 1.25 1.50 RUBBLE """il ------------------------------------------------------- 4-B-32 ~ Table 4-B-9.(Continued)• -. ----------------------------------------------~----~~--DEPTH VELOCITY FLOW SUBSTRATE ~' TRANSECT (ft )(ft/s)(cfs)PRIMARY SECONDARY ..... --------------------------~---------------------------- 8 .70 .80 1.12 RUBBLE SILT 8 .60 .65 .78 RUBBLE SILT -8 .60 .50 .60 RUBBLE SILT 8 .60 .50 .60 RUBBLE SILT 8 .50 .60 .60 RUBBLE SILT 8 .10 .60 .48 RUBBLE SILT 8 .30 .50 .30 RUBBLE GRAVEL 8 .30 '.40 .24 GRAVEL SILT ~8 .30 .50 .30 GRAVEL SILT 8 .20 .15 .06 GRAVEL SILT 8 .10 0.00 O~OO RUBBLE SILT 8 .10 0.00 O~OO RUBBLE SILT 9 .10 0.00 0.00 RUBBLE SAND 9 .10 0.00 0.00 RUBBLE SAND 9 .20 .10 .04 RUBBLE SAND ~, 9 .30 .20 .12 GRAVEL SAND 9 .20 .30 .12 RUBBLE SAND 9 .30 .30 .18 RUBBLE SAND 9 .30 .30 .18 RUBBLE SAND ~\ 9 .35 .30 .35 RUBBLE 9 .50 .40 .40 RUBBLE 9 .54 .60 .65 RUJUlLE ~,~ 9 .50 .50 .50 RUBBLE 9 .60 .25 .30 RUBBLE SAND 9 .60 .20 .24 RUBBLE SAND ~ 9 .70 .40 .56 RUBBLE SAND.'~ 9 .60 .50 .60 RUBBLE SAND 9 .20 .45 .18 RUBBLE SAND 9 .50 .40 .,40 RUBBLE SAND ~ 9 .50 .60 .60 RUBBLE SAND 9 .50 .60 .60 RUBBLE SAND 9 .90 .40 .72 RUBBLE SAND 9 1.00 .60 1.20 RUBBLE SAND 9 LID .50 1.10 COBBLE SAND 9 1.20 .50 1.20 CO'BBLE SAND -~ 9 1.20 .60 1.44 RUBBLE SAND 9 1.10 .70 1.54 RUBBLE SAND 9 LOO .50 1.00 RUBBLE SAND 9 1.00 .60 1.20 RUBBLE SAND -, 9 .70 .50 .70 RUBBLE SAND 9 .80 .30 .48 RUBBLE SAND 9 .60 .50 .60 RUBBLE 9 .40 .50 .40 RUBBLE 9 .70 .45 .63 RUBBLE 9 .60 .40 .48 RUBBLE ------------------------------------------------------- 4-B-34 """(Continued).Table 4-B-9 • .~" ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSEGT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- 9 .50 .40 .40 RUBBLE 9 .10 0.00 0.00 RUBBLE 10 .30 0.00 0.00 SILT r'"10 .60 0.00 0.00 SILT GOBBLE 10 .50 .10 .10 RUBBLE SILT 10 .50 .05 .05 SILT RUBBLE 10 .60 .10 .12 SILT RUBBLE 10 .60 .10 .12 SILT RUBBLE 10 .70 .10 .14 SILT RUBBLE 10 .70 .05 .07 SILT RUBBLE 10 .90 .05 .09 SILT RUBBLE 10 1.00 .10 .20 SILT RUBBLE 10 •75 0.00 0.00 SILT RUBBLEr-IO .60 .20 .24 SILT RUBBLE 10 .50 .15 .15 SILT 10 .65 .25 .33 SILT 10 .80 .25 .40 SILT 10 •70 .40 .56 SILT 10 •70 .30 .42 SILT 10 •70 .35 .49 SILT 10 .80 .45 •72 SILT RUBBLE 10 .90 .40 .72 SILT 10 .90 .60 1.08 SlLT '!"""10 1.10 .55 1.21 SILT 10 1.10 .60 1.32 RUBBLE SILT 10 1.30 .50 1.30 RUBBLE SILT 10 1.40 .55 1.54 RUBBLE SILT 10 1.40 .70 1.96 RUBBLE SILT 10 1.10 .60 1.32 RUBBLE SILT 10 1.20 .40 ,<~96 RUBBLE SILT 10 .80 .65 1.04 COBBLE SILT 10 1.00 .35 .70 RUBBLE SILT 10 .60 .45 .54 RUBBLE SILT 10 .60 .45 .54 RUBBLE SILT 10 .70 .30 .42 RUBBLE SILT 10 .70 .10 .14 RUBBLE 10 .50 .20 .20 RUBBLE 10 .30 0.00 0.00 RUBBLE 10 .10 0.00 0.00 RUBBLE 11 0.00 0.00 11 .10 0.00 0.00 RUBBLE 11 .40 0.00 0.00 RUBBLE 11 .50 0.00 0.00 RUBBLE,...,.'11 .20 0.00 0.00 RUBBLE I 11 0.00 .0.00 0.00 RUBBLEI /,&~ ------------------~-------------------------------------4-B-35 ~.. ~, Table 4-B-9.(Continued). ~ -------------------------------------------------------"",.DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft )(ft/s)(cfs)PRIMARY SECONDARY """!! ------------------------------------------------------- 11 .60 0.00 0.00 RUBBLE 11 .40 0.00 0.00 RUBBLE ~ 11 0.00 0.00 0.00 RUBBLE 11 0.00 0.00 0.00 RUBBLE 11 0.00 0.00 0.00 RUBBLE 11 .01 0.00 0.00 RUBBLE 11 0.00 0.00 0.00 RUBBLE 11 .04 0.00 0.00 SAND """I11.50 .50 .50 SAND 11 .40 .40 .32 SILT RUBBLE 11 .50 .10 .10 SILT RUBBLE 11 .40 .10 .08 SILT 11 .40 .20 .16 SILT 11 .40 .30 .24 SILT 11 .60 .40 .48 SILT 11 1.10 .35 .77 SILT 11 1.30 .50 1.30 SILT 11 1.40 .45 1.26 SILT RUBBLE 11 1.60 .90 2.88 SILT RUBBLE 11 1.90 .90 3.42 SILT RUBBLE 11 1.70 .80 2.72 SILT RUBBLE 11 1.50 .70 2.10 RUBBLE SILT ~.~ I 11 1.50 .40 1.20 RUBBLE SILT 11 1.70 .30 1.02 RUBBLE SILT 11 .90 .20 .36 RUBBLE 11 .50 0.00 0.00 RUBBLE 11 .10 .0.00 0.00 ------------------------------------------------------- ~/Summarized in Appendix Table 4-B-3.- 4-8-36 ..... I I -, Table 4-B-10.(Continued)• ~ ---------------~------------------------------------~-- DEPTH -;"VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ~ --------------------------------------------~---------- 2 .55 .40 .43 SILT COBBLE 2 .40 .31 .25 SILT COBBLE ~ 2 .45 0.00 0.00 SILT COBBLE 2 .60 0.00 0.00 SILT COBBLE 2 .50 0.00 0.00 SILT COBBLE -2 .30 0.00 0.00 SILT COBBLE 2 .40 0.00 0.00 SILT COBBLE 2 .30 0.00 0.00 SILT COBBLE 2 .60 .22 .26 SILT COBBLE 2 .55 .15 .16 SILT COBBLE 2 .80 .40 .64 SILT COBBLE 2 .70 .36 .50 SILT COBBLE:~ 2 .55 .64 .70 SILT COBBLE 2 .50 .41 .41 SILT COBBLE 2 .50 .60 .60 SILT COBBLE ~2 .50 .44 .44 SILT COBBLE 2 .30 .51 .31 SIL!COBBLE 2 .40 .54 .43 SILT COBRLE 2 .30 .35 .21 SILT COBBLE ,~ 2 .40 .26 .21 SILT COBBLE 2 .20 0.00 0.00 SILT COBBLE 2 .30 .37 .22 SILT COBBLE ~~ 2 .20 .30 .12 SILT COBBLE 2 .10 0.00 0.00 SILT COBBLE 2 .10 0.00 0.00 SILT COBBLE 2 .20 .12 .05 SILT COBBLE 2 .05 0.00 0.00 SILT COBBLE 2 .20 0.00 0.00 SILT COBBLE 3 .01 0.00 0.00 3 .01 0.00 0.00 3 0.00 0.00 0.00 3 .10 0.00 0.00 3 .20 0.00 0.00 3 .30 0.00 0.00 3 .40 .16 .13 ~3 '.40 .15 .12 3 .35 0.00 0.00 3 .35 .14 .10 3 .45 .31 .25 ~ 3 .55 .20 .20 3 .60 .38 .42 3 .55 .78 .82 3 .50 .70 ,,68 3 .50 .67 .65 3 .40 1.09 .85 ""'l', ---------------------~----------~---------------------- 4-B-38 Table 4-B-I0.(Continued). ""'"------------------------------------------------------- DEPTH ~VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY """"-----------------------------------------~------------- 4 .15 .91 .26 COBBLE RUBBLE 4 .20 1.02 .40 COBBLE RUBBLE ~. 4 .20 1.48 .59 COBBLE RUBBLE 4 .20 1.67 .67 COBBLE RUBBLE 4 .20 1.02 .41 COBBLE RUBBLE 4 .20 1.90 .76 COBBLE RUBBLE 4 .20 1.58 .63 COBBLE RUBBLE 4 .20 .96 .38 COBBLE RUBBLE 4 .15 1.05 .31 COBBLE RUBBLE 4 .10 0.00 0.00 COBBLE RUBBLE 4 .05 0.00 0.00 COBBLE RUBBLE 4 .05 0.00 0.00 COBBLE RUBBLE 4 .10 1.37 .27 COBBLE RUBBLE 4 .05 0.00 0.00 COBBLE RUBBLE 4 .05 0.00 0.00 COBBLE RUBBLE """I 4 .05 0.00 0.00 COBBLE RUBBLE 4 .05 0.00 0.00 COBBLE RUBBLE 4 .15 .20 .06 COBBLE RUBBLE 5 0.00 0.00 COBBLE RUBBLE 5 .10 0.00 0.00 COBBLE RUBBLE 5 .20 0.00 0.00 COBBLE RUBBLE 5 .30 0.00 0.00 COBBLE RUBBLE ,,-..~ 5 .45 0.00 0.00 COBBLE RUBBLE 5 .45 0.00 0.00 COBBLE RUBBLE 5 .45 0.00 0.00 COBBLE RUBBLE ~ 5 .40 0.00 0.00 .COBBLE RUBBLE 5 .30 0.00 0.00 COBBLE RUBBLE 5 .25 0.00 0.00 COBBLE RUBBLE 5 .10 0.00 0.00 COBBLE RUBBLE 5 0.00 0.00 0.00 COBBLE RUBBLE 5 0.00 0.00 0.00 COBBLE RUBBLE 5 .05 0.00 0.00 COBBLE RUBBLE """I 5 0.00 0.00 0.00 COBBLE RUBBLE 5 .05 0.00 0.00 COBBLE RUBBLE 5 .05 0.00 0.00 COBBLE RUBBLE 5 .10 .41 .08 COBBLE RUBBLE 5 .15 .55 .16 COBBLE RUBBLE 5 .15 .55 .16 COBBLE RUBBLE 5 .25 .52 .26 COBBLE RUBBLE -5 .30 .73 .44 COBBLE RUBBLE 5 .40 .91 .72 COBBLE RUBBLE 5 .30 .83 .50 COBBLE RUBBLE ~. 5 .20 .93 .37 COBBLE RUBBLE 5 .25 .95 .48 COBBLE RUBBLE 5 .30 1.02 .61 COBBLE RUBBLE - ----~----------------~---------------~----------------- 4-B-40 Table 4-B-10.(Continued)• ~" ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft!s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- ~ 5 .20 .71 .28 COBBLE RUBBLE 5 .40 .42 .33 COBBLE RUBBLE 5 .20 .25 .10 COBBLE RUBBLE p ..5 .30 .29 .16 COBBLE RUBBLE 5 .30 .19 .11 COBBLE RUBBLE 5 .30 .01 .01 COBBLE RUBBLE 5 .30 0.00 0.00 COBBLE RUBBLE 5 .30 0.00 0.00 COBBLE RUBBLE 5 .25 0.00 0.00 COBBLE RUBBLE 5 .30 .0.00 0.00 COBBLE RUBBLE 5 .30 0.00 0.00 COBBLE RUBBLE 5 .05 0.00 0.00 COBBLE RUBBLE 5 0.00 COBBLE RUBBLE 6 .10 6 .15 .20 .06 6 .25 .07 .03 6 .35 .13 .09 6 .30 .21 .13 6 .35 .13 .09 ~".~-6 .35 0.00 0.00 6 .45 .23 .20 6 .45 .23 .20 6 .40 .23 .19 6 .50 .33 .33 6 .50 .06 .06 6 .70 .23 .32 6 .85 .15 .24 6 .95 .03 .05 6 1.00 .32 .64 6 1.00 .33 .67 6 1.05 .39 .82 6 .50 0.00 0.00 6 .40 .13 .10-6 .45 .19 .17 6 .50 .14 .14 6 .50 .11 .11 6 .35 .03 .02 6 0.00 0.00 0.00 7 0.00 7 .10 0.00 0.00 SAND COBBLE 7 .10 0.00 0.00 SAND COBBLE 7 .20 0.00 0.00 SAND COBBLE 7 .35 0.00 0.00 SAND COBBLE ,'-7 .30 0.00 0.00 SAND COBBLE 7 .40 0.00 0.00 SAND COBBLE ------------------------------------------------------- 4-B-41 ~Table 4-B-I0.(Continued).---------------------------------------------------------DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- ..... 9 1.50 0.00 0.00 9 1.50 0.00 0.00 9 1.50 0.00 0.00 9 1.40 0.00 0.00 9 1.40 0.00 0.00 9 1.40 0.00 0.00 9 1.40 0.00 0.00 9 1.40 0.00 0.00 9 1.50 0.00 0.00 9 1.40 0.00 0.00 9 1.30 0.00 0.00 9 1.30 0.00 0.00 9 1.50 0.00 0.00 9 1.30 0.00 0.00 9 1.20 0.00 0.00 9 1.40 0.00 0.00 f"'"9 1.50 0.00 0.00 9 1.70 0.00 0.00 9 2 .30 0.00 0.00 9 2.90 0.00 0.00r""".,,,,,",,,9 3.40 0.00 0.00 9 3.10 0.00 0.00 9 2.40 0.00 0.00--9 1.70 0.00 0.00 ------------------------------------------------------- - - .... - 4-6-43 - _.---- ~, Table 4-B-11 •Hydraulic habitat variables~1 collected at transects ~n Slough·9,Aug 25,1982.- /'~------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE .~ TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------~ 1 SAND 1 .20 .10 .01 COBBLE RUBBLE 1 .50 .05 .05 COBBLE RUBBLE 1 .60 .10 .12 COBBLE RUBBLE 1 .60 0.00 0.00 COBBLE RUBBLE 1 .60 .08 .10 COBBLE RUBBLE 1 .55 .10 .11 COBBLE RUBBLE 1 .60 .10 .12 COBBLE RUBBLE 1 .70 .12 .17 COBBLE RUBBLE 1 .75 .10 .15 COBBLE RUBBLE 1 .70 .12 .17 COBBLE RUBBLE 1 .70 .12 .17 CO;BBLE RUBBLE !.60 .12 .14 COBBLE RUBBLE 1 .50 .10 .10 COBBLE RUBBLE 1 .60 .05 .06 COBBLE RUBBLE 1 .70 .10 .14 COBBLE RUBBLE 1 .55 .10 .11 COBBLE RUBBLE 1 .50 .10 .10 COBBLE RUBBLE -1 .60 .15 .18 COBBLE RUBBLE 1 .60 .12 .14 COBBLE RUBBLE 1 .60 .22 .26 COBBLE RUBBLE -1 .70 .25 .35 SAND 1 .70 .28 .39 SAND 1 .70 .30 .42 SAND -1 .60 .25 .30 SAND 1 SAND 1 .40 .15 .12 SAND 1 .30 .08 .05 SAND 1 .20 0.00 0.00 SAND 1 .10 0.00 0.00 SAND 1 0.00 0.00 SAND 2 SAND 2 .30 .20 .03 SAND 2 .40 .30 .24 GRAVEL RUBBLE 2 .40 .12 .10 GRAVEL RUBBLE 2 .40 .03 .02 GRAVEL RUBBLE 2 .50 .05 .05 GRAVEL RUBBLE 2 .40 0.00 0.00 GRAVEL RUBBLE -2 .25 0.00 0.00 GRAVEL RUBBLE 2 .30 0.00 0.00 GRAVEL RUBBLE 2 .40 .05 .04 GRAVEL RUBBLE 2 .50 .20 .20 GRAVEL RUBBLE 2 .50 .05 .05 GRAVEL RUBBLE 2 .70 .22 .31 GRAVEL RUBBLE ------------------------------------------------------- 4-B-44 Table 14-B-ll.(Continued).-.------------------------------------------------------- 1'""DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft )Cft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- ~ 7 .50 .10 .10 SAND RUBBLE 7 .45 .10 .09 SAND RUBBLE 7 .45 .10 .09 SAND RUBBLE ~illl 7 .30 .10 .06 SAND RUBBLE 7 .25 .05 .03 SAND RUBBLE 7 .25 .02 .01 SAND RUBBLE 7 .45 .01 .01 SAND 7 .50 .05 .05 SAND 7 .60 .08 .01 SAND 7 .65 .08 .10 SAND 7 .65 .08 .10 SAND 7 .65 .08 .10 SAND 7 .70 .08 .11 SAND,-7 .60 .10 .12 SAND 7 .70 .10 .14 SAND 7 .75 .10 .15 SAND 7 .80 .10 .16 SAND 7 .75 .10 .15 SAND 7 .55 .10 .11 SAND 7 .30 0.00 0.00 SAND:~"~ 7 .20 0.00 0.00 SAND 7 SAND 8 SAND.....8 .20 0.00 0.00 'SAND 8 .35 0.00 0.00 SAND 8 .55 0.00 0.00 SAND 8 .80 0.00 0.00 SAND 8 1.00 .05 .10 SAND 8 1.15 .08 .18 SAND 8 1.30 .05 .13 SAND 8 1.50 .05 .15 SAND 8 1.70 .05 .17 SAND 8 1.80 .05 .18 SAND 8 1.70 .03 .10 SAND 8 1.70 .05 .17 SAND 8 1.30 .05 .13 SAND """8 1.80 0.00 ·,~o SAND 8 1.90 '.05 .19 SAND 8 2.10 .02 .08 SAND 8 2.20 .02 .09 SAND gJ'#W'\8 2.30 .05 .23 SAND 8 2.40 .08 .38 SAND 8 2.45 .02 .10 SAND .~8 2.50 .02 .10 SAND 8 2.30 .02 .09 SAND.-. ---------------------------------------------------------4-B-47 ~j Table 4-B-ll.(Continued)• ~ --------------------------------------------'----------- DEPTH VELOCITY FLOW SUBSTRATE /""" TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ~ ------------------------------------------------------- 8 2.20 .01 .04 SAND 8 2.00 .01 .04 SAND ~ 8 1.65 .02 .07 SAND 8 1.40 0.00 0.00 BOULDER SAND 8 .75 .01 .02 BOULDER SAND 8 .65 0.00 0.00 BOULDER SAND 9 COBBLE 9 0.00 0.00 0.00 COBBLE ~ 9 .10 0.00 0.00 COBBLE 9 .20 0.00 0.00 COBBLE 9 .30 .02 .01 COBBLE 9 .30 0.00 0.00 COBBLE ~~ 9 .40 .02 .02 COBBLE 9 .60 .08 .01 COBBLE 9 .90 .08 .14 COBBLE ~ 9 1.20 .08 .19 COBBLE SAND 9 1.45 .08 .23 SAND 9 1.40 .08 .22 SAND 9 '1.30 .08 .21 SAND 9 1.25 .08 .20 SAND 9 1.25 .02 .05 SAND 9 1.25 .05 .13 SAND ~."""'1 9 1.35 .05 .14 SAND 9 1.25 .05 .13 SAND 9 1.25 .05 .13 SAND -9 1.30 .03 .08 SAND 9 1.15 .05 .12 SAND 9 1.20 .05 .12 SAND '"""9 1.20 .05 .12 SAND 9 1.15 .03 .07 SAND 9 1.10 .10 .22 SAND 9 1.30 .03 .21 SAND 9 1.50 0.00 0.00 SAND 9 1.65 .02 .07 SAND 9 2.20 .02 .09 SAND ~~ 9 2.85 .01 .03 BOULDER SAND 9 3.35 0.00 0.00 BOULDER SAND 9 2.90 .03 .17 BOULDER SAND 9 2.35 .05 .24 BOULDER SAND ~ 9 1.80 .02 .07 BOULDER SAND 10 SAND 10 .10 0.00 0.00 SAND ~J 10 .30 0.00 0.00 SAND 10 .35 0.00 0.00 SAND 10 .40 .01 .01 SAND ...." ---------------------------------~---------------------4-B-48 .-Table 4-B-ll •(Continued)• .~" ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE tRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY -~----------------------------------------------------- 10 .40 .02 .02 SAND 10 .65 .02 .03 SAND 10 .95 .02 .04 SAND ~10 1.15 .03 .07 SANDI I 10 1.40 .05 .14 SAND I 10 1.60 .08 .26 SAND-10 1.90 .10 .38 SAND 10 2.15 .10 .43 SAND 10 2.35 .02 .09 SAND 10 2.65 .07 .38 SAND....10 2.85 .08 .46 SAND 10 2.80 .01 .06 SAND 10 2.70 .09 .49 SAND......10 2.60 .07 .35 SANDI102.50 .10 .48 SAND 10 2.45 .10 .49 .SAND 10 2.45 .10 .49 SAND 10 2.45 .08 .39 SAND 10 2.70 .07 .38 SAND 10 3.00 .01 .06 SAND BOULDER ,~~10 3.65 .01 .07 SAND BOULDER 10 3.40 .02 .10 SAND BOULDER 10 .90 .02 .04 SAND BOULDER .-10 .30 0.00 0.00 SAND BOULDER!A .20 0.00 0.00 GRAVEL RUBBLE A .15 0.00 0.00 GRAVEL RUBBLE A .15 0.00 0.00 GRAVEL RUBBLE A .30 .15 .09 GRAVEL RUBBLE A .40 .10 .08 GRAVEL RUBBLE A .40 .28 .22 GRAVEL RUBBLE-A .35 .25 .18 GRAVEL RUBBLE A .45 .25 .23 GRAVEL RUBBLE A .45 .15 .14 GRAVEL RUBBLE .....A .45 .25 .23 GRAVEL RUBBLE A .50 .45 .45 GRAVEL RUBBLE A .65 .40 .52 GRAVEL RUBBLE A .60 .45 .54 GRAVEL RUBBLE A .60 .55 .66 GRAVEL RUBBLE A .55 .50 .55 GRAVEL RUBBLE A .45 .45 .41 SAND A .40 .50 .40 SAND A ~45 .50 .45 SAND A .40 .45 .36 SAND A .40 .45 .36 SAND A .35 .60 .42 SAND .,~ --------~----------------------------------------------....4-B-49 Table 4-B-ll.(Continued).--------------------------------------------------------"-... DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ~ ------------------------------------------------------- A .40 .50 .40 SAND A .35 .45 .32 SAND A .35 .40 .28 SAND A .30 .45 .27 SAND A .45 .25 .23 SAND A .35 .05 .04 SAND A .20 0.00 0.00 SAND B 0.00 COBBLE RUBBLE B .40 .05 .04 COBBLE RUBBLE B .70 .15 .21 COBBLE RUBBLE B .85 .20 .34 COBBLE RUBBLE B 1.20 .20 .48 COBBLE RUBBLE 8'J!ll B 1.20 .20 .48 COBBLE RUBBLE B 1.30 .20 .52 COBBLE RUBBLE B 1.30 .20 .52 COBBLE RUBBLE -B 1.30 .20 .52 COBBLE RUBBLE B 1.95 .25 .98 COBBLE RUBBLE B 2.05 .20 .82 COBBLE RUBBLE ~ B 2.00 .25 1.00 COBBLE RUBBLE B 2.00 .25 1.00 SAND SILT B 1.90 .25 .95 SAND SILT B 1.20 .25 .60 SAND SILT ~- B 1.20 .20 .48 SAND SILT B 1.00 .20 .40 .SAND SILT B .80 .20 .32 SAND SILT -B .80 .20 .32 SAND SILT B .70 .20 .28 SAND SILT B .65 .15 .20 SAND SILT ...., B .60 .10 .12 SAND SILT B .50 .05 .05 SAND SILT B SAND SILT C SILT C .10 0.00 0.00 SILT C .20 0.00 0.00 SILT C .30 0.00 0.00 SILT C .50 .08 0.00 SILT C .70 .08 .11 SILT C .85 .10 .17 SILT P'l'fflC1.10 .10 .22 SILT C 1.10 .13 .29 SILT C 1.20 .13 .31 SILT C 1.25 •15 .38 SILT ..... C 1.30 .13 .34 SILT SAND C 1.40 .15 .42 SILT SAND C 1.50 .15 .45 SILT SAND ..... ------------------------------------------------------- 4-B-50 ~ ~Table 4-B-11.(Continued).'--------------------------------------------------------....DEPTH VELOCITY FLOH SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- C 1.50 .10 .30 SILT SAND C 1.50 .15 .45 SILT SAND C 1.60 .13 .42 SILT SAND-C 1.65 .15 .50 SILT SAND! C 1.60 ,.10 .32 SILT SAND C 1.60 .10 .32 SILT SAND C 1.60 .10 .32 SILT SAND C 1.70 .10 .34 SILT SAND C 1.60 .10 .32 'SILT SAND C 1.60 .13 .42 SILT SAND C 1.60 .10 .32 SILT SAND C 1.30 .10 .26 SILT SAND C 1.20 .10 .24 SILT SAND C 1.10 .10 .22 SILT SAND C 1.10 .10 .22 SILT SAND C 1.00 .10 .20 SILT SAND C 1.00 .02 .04 SILT C .80 .05 .08 SILT C .60 .05 .06 SILT C .50 0.00 0.00 SILT~c~~,C .30 0.00 0.00 SILT C .20 0.00 0.00 SILT D 0.00 0.00 0.00 GRAVEL COBBLE D .20 .70 .28 GRAVEL COBBLE D .25 .85 .43 GRAVEL COBBLE D .30 .70 .42 GRAVEL COBBLE-D .20 .10 .04 GRAVEL COBBLE D .20 .30 .12 GRAVEL COBBLE D .10 .70 .14 GRAVEL RUBBLE D .20 .90 .36 GRAVEL RUBBLE D .20 .90 .36 GRAVEL RUBBLE D .30 1.15 .69 GRAVEL RUBBLE D .20 1.05 .42 GRAVEL RUBBLE D .20 1.50 .60 GRAVEL RUBBLE D .15 .80 .24 GRAVEL RUBBLE D .10 0.00 0.00 GRAVEL RUBBLE D .10 0.00 0.00 GRAVEL RUBBLE D .15 0.00 0.00 GRAVEL RUBBLE D .30 .40 .24 GRAVEL RUBBLE D .10 0.00 0.00 GRAVEL RUBBLE D .10 0.00 0.00 GRAVEL RUBBLE D .05 0.00 0.00 GRAVEL RUBBLE D .05 0.00 0.00 GRAVEL RUBBLE,-D 0.00 ------------------------------------------------------- !!./Summarized in Appendix Table 4-B-4. 4-B-'5l ~ Table 4-B-12.Hydraulic habitat variables~/collected at transects In Slough 9.Sep 04,1982. ------------------------------------------------------- DEPTH VELOCITY TRANSECT (f t)(ft /s) FLOW SUBSTRATE (cfs)PRIMARY SECONDARY ------------------------------------------------------- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 .20 .70 .80 .70 .70 .70 .70 .75 .80 .60 .65 .65 .65 .60 .80 .70 .70 .70 .75 .70 .70 .75 .75 .65 .60 .45 .30 .20 .10 .20 .30 .50 .50 .50 .50 .50 .35 .40 .40 .60 .50 .50 .40 0.00 .10 .18 .15 .10 .10 .10 .20 .15 .25 .30 .25 .20 .20 .20 .20 .28 .28 .32 .32 .52 .59 .55 .45 .40 .35 .25 .10 .10 .40 .32 .29 .10 .05 .08 0.00 .05 .05 .30 .40 .70 .50 0.00 .14 .29 .21 .14 .14 .14 .30 .24 .30 .39 .32 .26 .24 .32 .28 .39 .39 .48 .44 .73 .89 .83 .59 .48 .32 .15 .04 0.00 .24 .32 .29 .10 .05 .08 0.00 .04 .04 .36 .40 .70 .40 SAND SAND GRAVEL GRAVEL RUBBLE RUBBLE RUBBLE COBBLE GRAVEL GRAVEL GRAVEL GRAVEL GRAVEL GRAVEL SAND SAND GRAVEL SAND SAND SAND SAND SAND SAND SAND SAND SAND SAND SAND SAND SAND SAND SAND GRAVEL GRAVEL RUBBLE RUBBLE GRAVEL GRAVEL GRAVEL SAND GRAVEL GRAVEL GRAVEL GRAVEL RUBBLE COBBLE COBBLE SAND GRAVEL GRAVEL GRAVEL RUBBLE RUBBLE COBBLE RUBBLE COBBLE RUBBLE COBBLE RUBBLE COBBLE COBBLE COBBLE COBBLE COBBLE COBBLE RUBBLE RUBBLE RUBBLE COBBLE COBBLE COBBLE COBBLE COBBLE ~, ------------------------------------------------------- 4-B-52 Table 4-B-12.(Continued). ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ftl s)(cfs)PRIMARY SECONDARY ---------~--------------------------------------------- 2 .50 .60 .60 GRAVEL COBBLE 2 .70 .50 .70 GRAVEL BOULDER ~2 .55 .60 .66 GRAVEL COBBLE 2 .50 .52 .52 SAND COBBLE 2 .40 .60 .48 SAND GRAVEL 2 .40 .50 .40 GRAVEL SAND F""2 .40 .50 .40 GRAVEL 2 .40 .20 .16 GRAVEL RUBBLE 2 .30 .05 .03 SAND COBBLE 2 .35 .30 .21 SAND RUBBLE 2 .20 .28 .11 SAND RUBBLE 2 .20 .20 .08 SAND 2 .15 .20 .06 SAND GRAVEL 2 .20 .10 .04 SAND RUBBLE 2 .10 0.00 0.00 RUBBLE SAND 2 .20 .10 .04 GRAVEL ~4 .10 .02 0.00 GRAVEL 4 .20 0.00 0.00 GRAVEL 4 .25 0.00 0.00 GRAVEL ~'~"4 .25 .38 .08 GRAVEL 4 .20 .58 .09 GRAVEL SAND 4 .20 .42 .07 GRAVEL SAND 4 .20 .28 .01 SAND 4 .10 .30 .06 SAND 4 0.00 0.00 SAND 4 .05 .20 .02 GRAVEL SAND 4 .05 .30 .03 GRAVEL 4 .05 .28 .03 GRAVEL 4 .10 .15 .03 GRAVEL 4 .10 .20 .03 GRAVEL 4 .10 .50 .09 GRAVEL 4 .10 .60 .11 GRAVEL 4 .15 .40 .11 GRAVEL 4 .15 .60 .18 GRAVEL 4 .20 1.05 .41 GRAVEL 4 .20 1.00 .40 GRAVEL 4 .15 1.40 .41 GRAVEL 4 .20 1.70 .66 GRAVEL 4 .20 1.15 .45 GRAVEL RUBBLE 4 .20 2.00 .80 GRAVEL RUBBLE 4 .20 1.35 .54 GRAVEL RUBBLE 4 .20 1.75 .70 GRAVEL RUBBLE 4 .15 .75 .23 GRAVEL RUBBLE ~4 .20 .85 .34 GRAVELI 4 .15 .95 .29 GRAVEL ------------------------------------------------------- 4-B-53 Table 4-B-12.(Continued). ~. ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY -------------------------------------------------------- 4 .15 .10 .02 GRAVEL 4 .10 .80 .16 GRAVEL ~ 4 .15..60 .17 GRAVEL 4 .10 .30 .06 GRAVEL 4 .15 .65 .19 GRAVEL RUBBLE 4 .05 0.00 0.00 GRAVEL RUBBLE 4 .05 0.00 0.00 GRAVEL RUBBLE 4 .05 .25 .02 GRAVEL RUBBLE 4 ~.05 .20 .02 GRAVEL RUBBLE 4 .15 0.00 0.00 GRAVEL RUBBLE 4 .05 .10 .01 GRAVEL RUBBLE 4 .10 .15 .03 GRAVEL RUBBLE 4 .10 .10 .02 GRAVEL RUBBLE 4 GRAVEL RUBBLE 6 .05 0.00 RUBBLE i6.10 .05 .01 SAND RUBBLE 6 .20 .18 .07 RUBBLE COBBLE 6 .20 .25 .10 RUBBLE COBBLE 6 .20 .28 .11 RUBBLE COBBLE - 6 .40 .31 .25 RUBBLE COBBLE 6 .50 .39 .39 RUBBLE COBBLE 6 .50 .12 .12 COBBLE BOULDER ,-..." 6 .55 .29 .32 RUBBLE COBBLE 6 .45 .35 .32 RUBBLE COBBLE 6 .55 .35 .39 RUBBLE BOULDER 6 .35 .39 .27 RUBBLE BOULDER 6 .80 .35 .56 COBBLE BOULDER 6 .70 .38 .53 COBBLE BOULDER 6 .80 .42 .67 RUBBLE COBBLE 6 1.00 .31 .62 RUBBLE COBBLE 6 1.15 .35 .81 RUBBLE COBBLE 6 1.25 .42 .05 RUBBLE COBBLE ~ 6 1.20 .20 .48 RUBBLE COBBLE 6 .95 .29 .55 COBBLE RUBBLE 6 .75 .05 .08 RUBBLE COBBLE 6 .50 .02 .02 COBBLE BOULDER 6 .60 .29 '.35 COBBLE RUBBLE 6 .50 .22 .22 BOULDER RUBBLE 6 .50 .15 .14 COBBLE RUBBLE ""'" 7 0.00 RUBBLE GRAVEL 7 0.00 RUBBLE GRAVEL 7 .05 SAND 7 0.00 SAND 7 .05 GRAVEL SAND 7 .05 RUBBLE SAND ~ ------------------------------------------------------- 4-B-54 Table 4-B-12 •(Continued). .- ----------------------------------~-------------------- """DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (Et)(ft/s)(cfs)PRIMARY SECONDARY -----~------------------------------------------------- 7 .05 SAND RUBBLE 7 .10 0.00 0.00 RUBBLE SAND 7 .20 0.00 0.00 RUBBLE SAND 7 .20 0.00 0.00 RUBBLE COBBLE 7 .20 0.00 0.00 RUBBLE COBBLE 7 .35 .02 .01 RUBBLE COBBLE 7 .40 .05 .04 GRAVEL RUBBLE 7 .45 .10 .09 SAND RUBBLE 7 .30 .10 .06 COBBLE GRAVEL 7 .55 .10 .11 SAND COBBLE 7 .50 .15 .15 RUBBLE BOULDER 7 .80 .15 .24 RUBBLE SILT 7 .-80 .17 .27 SAND SILT 7 .60 .16 .19 COBBLE BOULDER 7 .60 .15 .18 SAND SILT 7 .70 .20 .28 SAND COBBLE ""'"7 •70 .15 .21 SAND SILT 7 •70 .20 .28 SAND SILT 7 •70 .20 .28 SAND SILT 7 .65 .23 .30 SAND SILT ~.d'-'"7 .60 .20 .24 SAND SILT 7 .60 .20 .24 SAND SILT 7 .55 .18 .20 SAND SILT 7 .45 .20 .18 SAND SILT 7 .40 .20 .16 SAND 7 .45 .18 .16 SAND 7 .60 .18 .22 SAND SILT 7 .60 .20 .24 SAND SILT 7 .60 .17 .20 SAND SILT 7 •70 .18 .25 SAND SILT 7 •75 .15 .23 SAND SILT 7 •75 .15 .23 SAND SILT 7 .80 .20 .32 SAND SILT 7 .80 .15 .24 SAND SILT 7 .80 .15 .24 SAND SILT 7 .80 .18 .29 SAND SILT 7 •85 .20 .34 SAND SILT-7 .90 .20 .36 SAND SILT 7 .80 .20 .32 SAND SILT 7 .50 .15 .15 SAND SILT 7 .30 .10 .06 SAND SILT 7 .15 .02 .01 SAND SILT 8 .20 0.00 0.00 SILT SAND 8 .35 0.00 0.00 SILT SAND 8 .55 0.00 0.00 SILT SAND "'~------------------------------------------------------- 4-B-55 - ~Table 4-B-12.(Continued). ,~ -----------------------------------~-,------------------ """'DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (it )(ft/s)(cis)PRIMARY SECONDARY ------------------------------------------------------- 9 1.40 .13 .36 SAND SILT 9 1.30 .19 .49 SAND·SILT 9 1.35 .15 .41 SAND SILT.....9 1.35 .18 .49 SAND SILT 9 1.30 .12 .31 SAND SILT 9 1.30 .15 .39 SAND SILT 9 1.45 .12 .39 SAND SILT 9 1.70 .10 .34 SAND SILT 9 1.80 .10 .36 SAND SILT 9 2.15 .10 .43 SAND SILT 9 2.70 .08 .43 SAND SILT 9 2.35 .02 .09 BOULDER SILT 9 2.15 .02 .09 BOULDER SILT,....9 1.25 .01 .01 BOULDER SAND 10 .10 0.00 0.00 SAND SILT 10 .40 0.00 0.00 SAND SILT .....10 .60 0.00 0.00 SAND SILT 10 .50 .0.00 0.00 SAND SILT 10 .50 0.00 0.00 SAND SILT 10 .50 0.00 0.00 SAND SILT ,..,,~10 .80 0.00 0.00 SAND SILT 10 1.05 .05 .11 SAND SILT 10 1.30 .11 .29 SAND SILT 10 1.50 .12 .36 SAND SILT 10 1.80 .15 .54 SAND SILT 10 2.10 .11 .46 SAND SILT 10 2.25 .11 .50 SAND SILT 10 2.60 .11 .57 SAND SILT 10 2.90 .12 .70 SAND SILT 10 3.25 .12 .78 SAND SILT-10 3.55 .11 .78 SAND SILT 10 3.70 .10 .74 SAND SILT 10 3.45 .10 .69 SAND SILT 10 3.20 .11 .70 SAND SILT 10 2.90 .10 .58 SAND SILT 10 2.90 .10 .58 SAND SILT-10 3.00 .09 .54 SAND SILT 10 2.85 .10 .57 SAND SILT 10 2.65 .07 .37 SAND SILT 10 2.45 .05 .25 SAND SILT f"'"10 1.30 .08 .21 BOULDER SAND 10 1.30 .02 .02 BOULDER SAND 10 0.00 0.00 0.00 BOULDER SAND A GRAVEL RUBBLE A .10 GRAVEL RUBBLE ------------------------------------------------------- 4-B-57 -Table 4-B-12.(C~nt inued).,,- ------------------------------------------------------- ..-DEPTH \VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- fiiIii'~B 1.70 .30 1.02 RUBBLE BOULDER B 1.75 .35 1.23 RUBBLE COBBLE B .85 .39 .66 SAND BOULDER B 1.50 .35 1.05 SAND B 1.30 .40 1.04 SAND B 1.30 .40 1.04 SAND B 1.15 .40 .92 SAND B 1.05 .40 .84 SAND B 1.05 .33 .69 SAND B .90 .15 .27 SAND B .60 0.00 0.00 SAND B SAND C SILT C .05 SILT c .10 SILT C .15 0.00 0.00 SILT C .20 .01 0.00 SILT C .20 .01 0.00 SILT C .30 .10 .06 SILT c .30 .10 .06 SILT C .40 .15 .12 SILT C .50 .20 .20 SILT C .80 .20 .32 SILT .-C 1.00 .20 .40 SILT c 1.20 .28 .67 SILT C 1.30 .25 .65 SILT c 1.40 .25 .70 SILT..... C 1.45 .22 .64 SILT C 1.45 .22 .64 SILT c 1.55 .22 .68 SILT-C 1.60 .20 .64 SILT c 1.70 .20 .68 SILT C 1.75 .20 .70 SILT ..-C 1.80 .20 .72 SILT C 1.80 .20 .72 SILT C 1.85 .20 .74 SILT C 1.90 .19 .72 SILT C 1.90 .15 .57 SILT C 1.90 .20 .76 SILT c 1.90 .19 .72 SILT C 1.90 .19 .72 SILT C 1.90 .19 .72 SILT C 2.10 .16 .67 SILT C 1.75 .13 .46 SILT c 1.60 .12 .38 SILT ------------------------------------------------------- 4-B-59 ~ Table 4-B-l2.(Continued). ~ ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE /""";" TRANSECT (ft )(ftl s)(cfs)PRIMARY SECONDARY ~ ---------~--------------------------------------------- C 1.50 .12 .36 SILT C 1.50 .12 .36 SILT C 1.35 .12 .32 SILT C 1.30 .13 .34 SILT c 1.25 .12 .30 SILT C 1.10 .10 .22 SILT C .90 .10 .18 SILT C .80 .10 .16 SILT c .60 0.00 0.00 SILT C .40 0.00 0.00 SILT C .20 0.00 0.00 SILT C SILT D SAND GRAVEL D .20 0.00 0.00 D .30 .25 .15 GRAVEL COBBLE D .40 .55 .44 GRAVEL RUBBLE D .30 .55 .33 GRAVEL RUBBLE D .25 1.35 .41 GRAVEL RUBBLE D .20 .90 .22 GRAVEL RUBBLE D .20 .95 .38 GRAVEL RUBBLE D .35 1.65 1.16 GRAVEL RUBBLE D .20 1.40 .56 GRAVEL RUBBLE ~-.~ D .40 2.00 1.60 GRAVEL RUBBLE D .30 1.35 .81 GRAVEL RUBBLE D .30 1.45 .87 GRAVEL RUBBLE -D .30 1.35 .81 GRAVEL RUBBLE D .15 .85 .26 GRAVEL RUBBLE D .25 .50 .25 GRAVEL D .15 .40 .12 GRAVEL - D .30 1.25 .75 GRAVEL D .20 ..60 .24 GRAVEL D .05 GRAVEL ..... D .10 GRAVEL D .15 .40 .12 'GRAVEL D .10 .50 .10 GRAVEL SAND ~ -----------------------~------------------------------- ~I Summarized in Appendix Table 4-B-4. - 4-B-60 ~, Table 4-B-13 •(Continued). """"----------------~-----------------------~---------~---- DEPTH VELOCITY FLOW SUBSTRATE ,.- TRANSECT (ft)(£t/s)(cfs).PRIMARY SECONDARY ~.------------------------------------------------------- 2 L20 2.20 10.60 SAND COBBLE 2 LOO 1.65 6.60 SAND COBBLE ~ 2 .95 1.75 6.70 SAND COBBLE 2 .85 1.40 4.80 SAND 2 .90 1.20 4.30 SAND 2 .75 1.05 3.20 SAND 2 .65 .90 .2.30 SAND 2 .50 .35 .70 SAND RUBBLE 2 .40 .48 .80 SAND RUBBLE 2 .10 0.00 0.00 SAND RUBBLE 2 0.00 0.00 SAND RUBBLE 4 .10 .25 0.00 COBBLE 4 .50 .88 1.30 COBBLE RUBBLE 4 .70 1.65 3.50 COBBLE RUBBLE 4 1.00 1.65 4.30 COBBLE ~4 1.10 2.00 5.70 COBBL.E 4 1.40 2.15 9.00 COBBLE GRAVEL 4 1.60 1.85 8.90 COBBLE GRAVEL 4 1.50 2.35 11.30 COBBLE GRAVEL ~ 4 1.80 2.10 11.30 SAND COBBLE 4 1.60 1.63 8.40 SAND COBBLE 4 1.30 1.60 7.50 SAND -. 4 1.60 1 •.65 9.50 SAND 4 1.10 1.10 4.40 SAND 4 1.10 1.15 4.60 SAND 4 1.20 1.10 4.80 SAND 4 1.20 1.15 5.20 SAND 4 1.20 .1.28 5.80 SAND 4 1.20 1.80 8.20 SAND 4 1.00 1.92 7.50 SAND 4 1.00 2.35 9.10 SAND 4 1.50 1.90 10.80 SAND -4 1.30 1.89 9.30 SAND RUBBLE 4 1.30 1.50 7.40 SAND 4 1.30 2.00 9.40 RUBBLE COBBLE """4 1.10 1.91 7.60 RUBBLE COBBLE 4 1.10 1.60 7.00 RUBBLE COBBLE 4 1.10 1..J8 6.10 RUBBLE COBBLE 4 1.00 1.80 6.80 RUBBLE COBBLE ~ 4 1.10 1.82 7.60 COBBLE RUBBLE 4 .80 1.75 5.30 BOULDER COBBLE 4 1.00 1.30 5.20 COBBLE RUBBLE 4 .90 1.05 3.60 RUBBLE COBBLE 4 .90 .88 3.00 RUBBLE COBBLE 4 .60 .52 1.20 COBBLE RUBBLE -----------------------------------------------.------- 4-B-62 - ,....Tab Ie 4-B-13.(Continued)• '~'\ ---------------------------------------------~---------DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (it)(£t/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- 4 .60 .62 1.30 RUBBLE COBBLE 4 .60 .40 .80 RUBBLE COBBLE 4 .40 .35 .40 COBBLE RUBBLE 4 .30 .28 .30 COBBLE RUBBLE 4 .20 .02 0.00 RUBBLE COBBLE 4 .15 .02 0.00 COBBLE RUBBLE 6 .70 .02 0.00 COBBLE 6 .80 .80 2.60 COBBLE 6 1.10 2.00 8.80 COBBLE 6 1.20 1.75 8.40 COBBLE 6 1.10 1.70 7.50 COBBLE SAND 6 1.00 1.65 6.60 COBBLE SAND 6 .90 1.50 5.40 SAND 6 .80 1.58 5.10 SAND 6 .70 1.38 3.90 SAND 6 .80 1.12 3.60 SAND 6 .60 1.25 3.00 SAND 6 .60 1.20 2.90 SAND 6 .50 1.20 2.40 SAND 6 .60 1.12 2.70 SAND F"-~6 .60 1.55 3.70 SAND 6 .60 1.48 3.60 SAND 6 .60 1.42 3 .40 SAND ~6 .70 1.35 3.80 SAND 6 .80 1.28 4.10 SAND 6 .90 .95 3.40 SAND 6 .90 1.42 5.10 SAND 6 1.00 1.75 7.00 SAND 6 1.20 2.00 9.60 SAND BOULDER 6 1.30 1.75 9.10 SAND..-6 1.40 1.70 9.50 .COBBLE SAND 6 1.50 2.15 12.90 COBBLE 6 1.60 2.10 13 .40 SAND COBBLE flIllk~6 1.70 2.15 14.60 COBBLE BOULDER 6 1.90 1.65 12.50 COBBLE BOULDER 6 2.30 2.05 18.90 COBBLE BOULDER 6 1.80 1.98 14.30 BOULDER COBBLE 6 1.60 1.88 12.00 BOULDER 6 1.50 1.60 9.60 BOULDER 6 .70 .55 1.50 BOULDER 6 .50 .70 1.40 COBBLE BOULDER 7 SAND 7 .40 .60 .30 SAND 7 .35 .75 1.10 SAND 7 .35 .65 .90 SAND ------------------------------------------------------- 4-B-63 Table4-B-13 •(Continued). ------~--------------------~--------------------------- ~, DEPTH VELOCITY TRANSECT (ft)(ft/s) FLOW'SUBSTRATE (cfs)PRIMARY SECONDARY ----------------------~-------------------------------- "...Table 4-B-13.(Continued). ~. ------------------------------------------------------- r-DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(it/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- 8 2.80 1.51 16.90 SAND 8 2.90 1.58 18.30 SAND 8 3.30 1.52 20.10 SAND 8 3.40 1.75 23.80 SAND 8 3.50 1.78 24.90 SAND 8 3.60 1.78 25.60 SAND 8 3.30 1.88 24.80 SAND 8 3.00 1.45 17.40 SAND 8 2.80 1.26 14.10 SAND COBBLE 8 2.45 .65 6.40 SAND BOULDER ~ .408.60 1.00 9 RUBBLE COBBLE 9 .05 0.00 0.00 RUBBLE COBBLE 9 .35 .40 .06 RUBBLE COBBLE 9 .45 .50 .09 RUBBLE COBBLE 9 .65 .65 1.70 RUBBLE COBBLE '"""9 .95 .90 3.40 RUBBLE COBBLE 9 1.15 .95 4.40 RUBBLE COBBLE 9 1.40 .85 4.70 RUBBLE COBBLE 9 1.60 1.30 8.30 RUBBLE COBBLE~.:~, 9 1.80 1.40 10.00 RUBBLE COBBLE 9 2.20 1.90 16.70 SAND 9 2.30 1.90 17.40 SAND 9 2.35 2.10 19.70 SAND 9 2.45 2.15 21.10 SAND 9 2.35 2.15 20.20 SAND 9 2.45 1.80 17 .60 SAND 9 2.30 1.80 16.60 SAND 9 2.20 1.15 15.40 SAND 9 2.30 1.55 14.30 SAND..-9 2.80 1.42 15.90 SAND 9 2.90 1.38 16.00 SAND 9 4.60 1.00 18.40 SAND BOULDER ""'"9 4.20 .35 5.90 SAND BOULDER 9 .30 0.00 0.00 10 SAND """10 .20 .25 .10 SAND 10 .60 .62 1.50 SAND 10 .1.30 .75 4.00 SAND 10 2.00 .90 7.20 SAND .10 2.50 1.41 14.10 SAND 10 2.80 1.50 16.80 SAND 10 2.80 .1.49 16.70 SAND ~10 3.00 1.63 19.60 SAND 10 3.10 1.60 19.80 SAND .,.-_:"I'IlI....... ---------------------~--------------------------------- 4-B-65 ..... Table 4-B-13.(Continued). -------------------~~--~~---------~------~------~---~-- DEPTH VELOCITY TRANSECT (ft)(ft/s) FLOW SUBSTRATE (cfs)PRIMARY SECONDARY -------------------------------~~---~-------~-~-------- 10 3.30 L82 24.00 SAND· 10 3.50 2.04 28.60 SAND 10 3.40 2.03 27.60 SAND 10 3.80 1.82 27.10 SAND to 3.90 1.71 26.70 SAND 10 4.30 1.26 21.70 SAND 10 4.70 .85 16.00 SAND 10 2.50 .11 7.iO SAND 10 1.20 ~20 i.oo BOULDER SAND 10 .50 .90 1.80 eOUl-OER SAND ~/Summarized in Appendix Table 4-B'-4. - - ..... Table 4-B-14.(Continued).-------~------------------------------------------------ DEPTH VELOCITY FLOW SUBSTRATE ~. TRANSECT (£t)(ft/s)(ds)PRIMARY SECONDARY -------------------------------------------------------- 2 .80 1.80 5.80 SAND 2 .60 1.55 3.70 SAND -2 .60 1.52 .3.70 SAND 2 .50 1.45 2.90 SAND 2 .40 .43 .70 SAND -2 .30 .25 .30 SAND 2 .20 0.00 0.00 SAND 4 .05 .38 0.00 COBBLE RUBBLE 4 .40 .96 1.20 COBBLE RUBBLE 4 .60 1.~O 2.50 4 1.00 1.15 3.80 RUBBLE COBBLE 4 1.00 1.25 4.30 COBBLE RUBBLE ~ 4 1.10 1.65 5.10 RUBBLE COBBLE 4 1.20 1.40 5.00 COBBLE GRAVEL 4 1.50 2.15 7.30 SAND COBBLE 4 1.20 1.72 6.20 GRAVEL SAND 4 1.10 1.38 4.90 COBBLE GRAVEL 4 1.00 1.20 4.70 COBBLE SAND 4 .90 1.21 4.40 SAND ..." 4 1.00 1.28 5.10 SAND 4 1.00 1.55 6.00 SAND 4 1.00 1.60 6.20 SAND ~...... 4 1.00 1.85 7.40 COBBLE GRAVEL 4 1.10 2.00 8.80 RUBBLE GRAVEL 4 1.00 1.90 7.60 COBBLE GRAVEL -4 1.00 2.09 8.40 COBBLE GRAVEL 4 .80 2.00 6.40 COBBLE GRAVEL 4 .70 2.40 6.70 COBBLE RUBBLE 4 .70 2.40 6.70 COBBLE RUBBLE ~ 4 .50 1.80 3.60 COBBLE RUBBLE 4 .60 .40 1.00 RUBBLE COBBLE 4 .70 1.12 3.10 COBBLE SAND ~. 4 .50 1.20 2.40 COBB.LE RUBBLE 4 .50 .98 2.00 COBBLE RUBBLE 4 .50 .80 1.60 COBBLE RUBBLE 4 .50 1.00 2.00 COBBLE RUBBLE 4 .40 .50 .80 COBBLE GRAVEL 4 .40 .48 .70 COBBLE RUBBLE 4 .40 .30 .50 COBBLE RUBBLE ~ 4 .40 .20 .30 RUBBLE GRAVEL 4 .10 0.00 0.00 RUBBLE GRAVEL 4 .05 0.00 0.00 RUBBLE "-1 4 .05 0.00 0.00 GRAVEL RUBBLE 6 .50 .32 .60 SAND 6 .40 .63 1.00 COBBLE RUBBLE ------------------------------------------------------- 4-B-68 .- (Continued).Table 4-B-14. ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- 6 .80 1.20 3.80 COBBLE RUBBLE 6 .90 2.03 7.30 COBBLE RUBBLE 6 .80 1.92 6.10 COBBLE SAND ~6 .70 1.73 4.80 SAND COBBLE 6 .50 1.25 2.50 SAND COBBLE 6 .30 1.20 1.40 SAND 6 .40 1.20 1.90 SAND 6 .40 1.23 2.00 SAND 6 .30 .75 .90 SAND 6 .20 .20 .10 SAND 6 .20 1.28 .80 SAND COBBLE 6 .30 1.40 1.50 COBBLE SAND 6 .30 .72 .80 COBBLE 6 .30 .98 1.10 SAND COBBLE 6 .30 .72 .80 SAND COBBLE 6 .40 1.00 1.60 SAND COBBLE 6 .40 .85 1.40 SAND 6 .40 1.10 1.70 SAND 6 .60 1.09 2.60 SAND COBBLE 6 .80 1.30 4.20 SAND ~-6 .90 1.38 5.00 SAND COBBLE 6 .60 1.85 4.40 COBBLE SAND 6 1.10 1.72 7.60 COBBLE SAND 6 1.10 2.10 9.20 COBBLE 6 1.10 1.92 8.50 COBBLE 6 1.50 1.75 10.50 COBBLE 6 1.70 1.80 12.20 COBBLE 6 1.90 1.80 13.70 COBBLE 6 1.00 2.35 9.40 BOULDER COBBLE 6 1.20 1.50 7.20 BOULDER COBBLE ~ 6 1.30 1.60 8.30 BOULDER COBBLE 6 .50 .60 1.20 COBBLE 6 .05 0.00 0.00 COBBLE ~7 .05 .25 .04 SAND 7 .10 .30 .12 SAND GRAVEL 7 .30 .60 .72 SAND COBBLE 7 .30 .60 .72 SAND GRAVEL 7 .20 .78 .62 7 .40 .78 1.25 RUBBLE GRAVEL 7 .50 1.09 2.18 SAND RUBBLE 7 .60 1.05 2.52 SAND 7 .60 .95 2.28 SAND COBBLE 7 .60 1.00 2.40 SAND COBBLE ~7 .70 1.10 3.08 SAND COBBLE 7 .70 1.25 3.50 SAND COBBLE ------------------------------------------------------- 4-B-69 -- .....Table 4-B-14.(Continued).,- ---------------------------------~----------------------DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft )(ft/s)(cfs)PRIMARY SECONDARY ---------------------------------~--------------------- 9 1.30 .98 5.10 9 1.65 1.13 7.50 9 2.05 .85 7.00 r-9 2.10 1.02 8.60 9 2.10 1.32 11.10 9 1.90 1.50 11.40 9 1.90 1.58 12.00 9 1.80 1.22 8.80 9 1.80 1.35 9.70 9 2.00 1.35 10.80 9 2.40 1.30 12.50 9 2.40 1.25 12.00 9 2.90 .93 11.70 ~9 3.30 .50 6.60 9 0.00 0.00 10 SAND SILT 10 .10 .02 0.00 SAND SILT-10 .80 1.30.39 .SAND SILT 10 1.60 .58 3.70 SAND SILT 10 2.00 .78 6.20 SAND SILT ~~:10 2.20 1.00 8.80 SAND SILT 10 2.30 1.09 10.00 SAND SILT 10 2.30 .98 9.00 SAND SILT 10 2.40 .90 8.60 SAND SILT 10 2.50 '1.15 11.50 SAND SILT 10 2.80 1.02 11.40 SAND SILT 10 3.00 1.24 14.80 SAND SILT 10 3.00 1.07 12.80 SAND SILT 10 3.10 1.01 12.50 SAND SILT 10 3.75 .78 11.70 SAND SILT 10 4.00 .68 10.80 SAND SILT 10 2.00 .24 0.00 SAND SILT 10 .70 0.00 SAND SILT ------------------------------------------------------- ~/Summarized in Appendix Table 4-B-4. 4-B-71 ~ Table 4-B-15.Hydraulic habitat variables~/collected at transects Slough 21,Sep 02,1982."""~n ,,;/lilt"';.>' ------------~------------------------------------------ DEPTH VELOCITY FLOW SUBSTRATE ..... TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- ..,. 1 .05 SAND 1 .15 0.00 0.00 SAND 1 .20 0.00 0.00 SAND 1 .20 0.00 0.00 SAND ~ 1 .40 0.00 0.00 SAND 1 .50 .10 .10 SAND 1 .50 .08 .08 SAND -1 .60 .06 .07 SAND 1 .75 .10 .15 SAND 1 .95 .08 .15 SAND 1 .95 .10 .19 SAND 1 1.10 .10 .22 SAND 1 1.20 .15 .36 SAND RUBBLE 1 1.00 .10 .20 SAND ~ 1 1.35 .10 .27 SAND BOULDER 1 1.60 .10 .32 COBBLE SAND 1 1.55 .05 .16 SAND RUBBLE ,.... 1 1.50 .10 .30 SAND 1 1.60 .10 .32 SAND RUBBLE 1 1.50 .12 .36 RUBBLE SAND 1 1.50 ..02 .06 SAND COBBLE ~- 1 1.35 .05 .14 SAND COBBLE 1 1.25 .10 .25 SAND COBBLE 1 1.15 .02 .05 SAND COBBLE 1 .85 .05 .09 SAND BOULDER 1 .95 .02 .04 SAND BOULDER 1 .45 .08 .07 ""'11.85 .10 .17 GRAVEL BOULDER 1 1.00 .02 .04 GRAVEL RUBBLE 1 .95 .12 .23 RUBBLE COBBLE 1 .15 .02 .01 COBBLE GRAVEL 1 .90 .10 .18 BOULDER RUBBLE 1 0.00 1 .55 .08 .09 SAND COBBLE 1 .55 .12 .13 SA-ND COBBLE 1 .50 .02 .02 SAND BOULDER 1 .70 .10 .14 GRAVEL COBBLE ~1 .90 .15 .27 GRAVEl-RUBBLE 1 .80 .20 .32 BOULDER GRAVEL 1 1.00 .12 .24 COBBLE GRAVEL 1 .90 .18 .32 BOULDER SAND 1 1.00 .10 .20 RUBBLE SAND 1 .60 .02 .02 SAND COBBLE 1 .30 0.00 0.00 COBBLE SAND -------------------------------~----~------------------ 4-B-72 Table 4-B-15 .(Continued). .~"---------------------------------_._-------------------- r-DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMRY SECONDARY ------------------------------------------------------- 1 .20 .02 .01 COBBLE 1 .15 0.00 0.00 COBBLE SILT 1 .20 0.00 0.00 RUBBLE COBBLE 1 0.00 1 .15 0.00 0.00 RUBBLE SILT 1 0.00 ~2 .20 0.00 0.00 RUBBLE 2 .25 0.00 0.00 RUBBLE GRAVEL 2 .40 0.00 0.00 RUBBLE GRAVEL 2 .60 0.00 0.00 GRAVEL RUBBLEr-2 .70 .09 .13 GRAVEL COBBLE 2 .85 .08 .14 RUBBLE GRAVEL 2 .80 .08 .13 GRAVEL RUBBLE 2 .85 .08 .14 RUBBLE GRAVEL 2 .80 .10 .16 COBBLE GRAVEL 2 .70 .02 .03 COBBLE GRAVEL 2 .60 0.00 0.00 COBBLE GRAVEL 2 .60 0.00 0.00 RUBBLE SAND 2 .40 0.00 0.00 RUBBLE GRAVEL 2 .20 0.00 0.00 RUBBLE COBBLE F',..t,~2 .10 0.00 0.00 RUBBLE COBBLE 2 .10 0.00 0.00 RUBBLE COBBLE 2 .20 0.00 0.00 RUBBLE BOULDER 2 .20 0.00 0.00 COBBLE RUBBLE 2 .10 0.00 0.00 GRAVEL COBBLE 2 .10 0.00 0.00 RUBBLE COBBLE 2 0.00 2 .20 0.00 0.00 RUBBLE 2 .20 .05 .02 COBBLE RUBBLE 2 .15 0.00 0.00 RUBBLE COBBLE 2 .10 .15 .15 COBBLE RUBBLE 2 0.00 2 .35 .25 .16 RUBBLE SILT-2 .30 .70 .32 RUBBLE BOULDER, 2 .40 .60 .46 BOULDER SAND 2 .40 .90 .72 GRAVEL COBBLE 2 .45 .90 .81 GRAVEL COBBLE~2 .60 1.10 1.32 GRAVEL COBBLE 2 .55 .30 .30 RUBBLE SAND 2 .40 .70 .56 RUBBLE BOULDER-2 .30 .30 .18 COBBLE SANDi 2 .30 .51 .31 RUBBLE BOULDER 2 .30 0.00 0.00 GRAVEL COBBLE 2 0.00 2 .30 .75 .45 RUBBLE BOULDER ------------------------------------------------------- 4-B-73 ~ Table 4-B-15.(Continued). ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ~I- TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- 3 .25 0.00 0.00 SILT 3 .50 .10 .10 -3 .45 .10 .09 SILT BOULDER 3 .60 .08 .10 SILT 3 .70 .10 .14 SILT COBBLE JIllfflIIl 3 .75 .10 .15 SILT BOULDER 3 .75 .18 .27 SILT BOULDER 3 .80 .20 .32 BOULDER SILT 3 1.00 .20 .40 BOULDER SILT 3 .70 .10 .12 BOULDER SILT 3 .45 .20 .18 BOULDER SILT 3 1.25 .12 .30 RUBBLE SILT 3 1.00 .15 .30 GRAVEL RUBBLE 3 1.30 .15 .39 GRAVEL RUBBLE 3 1.35 .20 .54 SAND BOULDER 3 .70 .20 .28 BOULDER SAND 3 1.20 .20 .48 GRAVEL COBBLE 3 1.15 .10 .23 GRAVEL COBBLE 3 .90 .10 .18 SAND -3 .90 .12 .22 SAND 3 .90 .20 .36 SAND 3 .80 .10 .16 SAND RUBBLE .~."""1 3 .80 .10 .16 SAND RUBBLE 3 •80 .10 .16 SAND COBBLE 3 .85 .08 .14 SAND COBBLE 3 .08 .11 MiJ.70 SAND COBBLE 3 .70 .02 .03 SAND BOULDER 3 .75 .05 .08 SAND COBBLE 3 .50 .05 .05 SAND COBBLE ~ 3 1.00 .05 .10 SAND BOULDER 3 .15 0.00 0.00 SAND BOULDER 4 .30 0.00 0.00 SILT SAND 4 .50 0.00 0.00 SILT SAND 4 .35 .05 .04 SILT SAND 4 .20 0.00 0.00 SILT SAND 4 .20 0.00 0.00 SILT SAND 4 .20 0.00 0.00 SILT SAND 4 .25 0.00 0.00 SILT SAND 4 .20 0.00 0.00 SILT SAND """4 .20 .05 .02 SILT SAND 4 .30 .09 .05 SILT SAND 4 .50 .15 .15 SILT SAND 4 .50 .24 .24 SILT SAND 4 .80 .25 .40 SILT SAND 4 •90 .30 .54 SILT SAND ~ ---------------~--------------------------------------- 4-B-74 - Table 4-B-15.(Continued). /""" ----------------------------------~-~------------------ 1""'\DEPTH VELOCITY FLOW SUBSTRATE tRANSECT (ft>(ft/s)(ds)PRIHARY SECONDARY ------------------------------------------------------- 1'"'" 4 1.10 .30 .66 SILT SAND 4 1.15 .20 .46 SILT SAND 4 1.30 .15 .39 SILT SAND 4 1.40 .12 .34 SILT SAND 4 1.75 .15 .53 SILT SAND 4 2.20 .08 .35 SILT SAND-4 2.35 .08 .38 SILT SAND 4 2.25 .10 .45 SILT SAND 4 2.25 .08 .36 SAND COBBLE 4 1.90 .03 .11 SAND COBBLE-4 1.70 .03 .10 COBBLESAND 4 1.45 0.00 0.00 SAND COBBLE 4 .90 0.00 0.00 SAND COBBLE 5 .40 .65 .47 SAND 5 .40 .40 .32 GRAVEL RUBBLE 5 .40 .60 .48 GRAVEL RUBBLE 5 .50 .95 .92 GRAVEL RUBBLE 5 .65 .35 .46 RUBBLE COBBLE 5 .40 .72 .58 COBBLE RUBBLE 5 .70 .15 .21 COBBLE SAND "-,5 .50 .40 .40 COBBLE RUBBLE 5 .60 .22 .26 GRAVEL RUBBLE 5 .60 .25 .30 GRAVEL RUBBLE ~5 .50 .22 .22 BOULDER SAND 5 .50 .13 .13 BOULDER SAND 5 0.00 0.00 0.00 COBBLE BOULDER ~Ili 5 0.00 0.00 0.00 COBBLE BOULDER 5 0.00 0.00 0.00 COBBLE BOULDER 5 0.00 0.00 0.00 COBBLE BOULDER 5 .30 .03 .02 COBBLE BOULDER.... 5 .40 .10 .08 COBBLE BOULDER 5 0.00 0.00 0.00 COBBLE BOULDER 5 .10 .03 .01 RUBBLE COBBLE 6 .05 GRAVEL RUBBLE 6 .05 GRAVEL RUBBLE 6 .10 0.00 0.00 GRAVEL RUBBLE F""6 0.00 0.00 0.00 RUBBLE COBBLE 6 0.00 0.00 0.00 RUBBLE COBBLE 6 .10 .12 .02 RUBBLE COBBLE 6 0.00 0.00 0.00 RUBBLE COBBLE 6 0.00 0.00 0.00 RUBBLE COBBLE 6 0.00 0.00 0.00 RUBBLE COBBLE 6 0.00 0.00 0.00 RUBBLE COBBLE 6 .10 .18 .04 RUBBLE COBBLE 6 .15 .60 .18 RUBBLE COBBLE ----------------------~--------------------------------"""'"4-B-75 -. """ Table 4-B-15.(Continued). """"-------------------------------------------------------'-'"DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY -------------------------------------------------------- 6 .30 .83 .50 GRAVEL RUBBLE 6 .35 2.05 1.44 GRAVEL RUBBLE 6 .40 1.10 .88 GRAVEL RUBBLE 6 .30 .60 .36 COBBLE RUBBLE 6 .50 .75 .75 COBBLE RUBBLE ~ 6 .20 .15 .06 COBBLE RUBBLE 6 .25 .25 .13 COBBLE RUBBLE 6 .15 .10 .03 COBBLE RUBBLE ..... 7 .10 0.00 GRAVEL RUJ3BLE 7 .10 0.00 GRAVEL RUBBLE 7 .35 .22 .15 GRAVEL RUBBLE 7 .55 .25 .28 GRAVEL RUBBLE ..... 7 .85 '.25 .43 GRAVEL RUBBLE 7 .90 .35 .63 GRAVEL RUBBLE 7 1.25 .32 .80 GRAVEL RUBBLE 7 1.20 .30 .72 GRAVEL RUBBLE 7 1.35 .25 .68 GRAVEL RUBBLE 7 1.30 .25 .65 GRAVEL RUBBLE 7 1.10 .15 .33 COBBLE 7 .35 .10 .07 BOULDER SAND 8 .70 0.00 0.00 GRAVEL RUBBLE 8 .90 0.00 0.00 GRAVEL RUBBLE --8 .40 0.00 0.00 SAND 8 .80 .05 .08 SAND GRAVEL 8 .80 .05 .08 GRAVEL """iI8.65 .05 .07 GRAVELI 8 •70 .08 .11 GRAVEL SAND 8 .85 .08 .14 GRAVEL SAND 8 •80 .09 .14 SAND GRAVEL 8 •80 .05 .08 SAND GRAVEL 8 1.20 .05 .12 GRAVEL 8 1.25 .02 .05 GRAVEL ~ 8 .95 .05 .10 SAND 8 .80 .09 .14 SAND 8 .85 .05 .09 SAND ~ 8 .95 .05 .10 GRAVEL SAND 8 1.10 .09 .20 GRAVEL SAND 8 1.05 .05 .11 SAND 8 .85 .02 .03 SAND ~ 8 .90 .01 .02 SAND 8 .90 .05 .09 SAND 8 .90 .05 .09 SAND -8 .80 .08 .13 SAND 8 .80 .05 .08 SAND 8 .75 .08 .12 SAND ..... ------------------------------------------------------- 4-B-76 - - 4-B-77 --- ~ Tab1.e 4-B-16.Hydraulic habitat variables~/collected ~ at transects in Slough 21.,Sep 17 •1982. #'" ------------------------~------------------------------ VELOCITY '"DEPTH FLOW SUBSTRATE ~ TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------~------------------ 1 .15 .05 .01 COBBLE SILT 1 .25 ..05 .03 COBBLE SILT 1 .30 .18 .11 SAND 1 .50 .22 .22 SAND ~ 1 .50 .21 .21 SAND 1 .60 .38 .46 SAND 1 .80 .51 .82 SAND ""'1 1 .90 .50 .90 SAND 1 1.10 .70 1.45 SAND 1 1.10 1.00 2.07 SAND 1 1.25 1.13 2.66 SAND 1 1.30 1.20 2.93 SAND 1 1.45 1.25 3.41 SAND 1 1.55 1.60 4.66 SAND -1 1.50 1.60 4.51 SAND 1 1.60 1.50 4.51 SAND 1 1.60 1.70 5.11 SAND 1 1.70 1.60 5.11 SAND 1 1.80 1.80 6.09 SAND 1 2.00 1.70 6.39 SAND 1 2.20 1.80 7.45 SAND ~~ 1 2.30 2.20 9.51 SAND 1 2.40 2.45 11.10 SAND 1 2.50 2.10 9.87 COBBLE SAND 1 2.60 1.90 9.29 COBBLE SAND 1 2.90 1.80 9.82 COBBLE SAND 1 3.00 1.90 10.30 COBBLE SAND -1 2.80 2.20 11 .10 COBBLE SAND 1 3.00 2.00 10.80 COBBLE SAND 1 3.10 1.90 10.60 COBBLE SAND 1 3.10 1.70 9.49 COBBLE SAND ~I 1 3.20 1.60 9.22 COBBLE SAND 1 3.20 1.70 9.79 COBBLE SAND 1 3.40 1.75 10.70 COBBLE SAND ~ 1 3.30 1.50 10.10 SAND COBBLE 1 3.50 1.65 9.45 SAND COBBLE 1 3.50 ·1.60 10.40 SAND COBBLE ~I 1 3.50 1.60 10.10 SAND COBBLE 1 3.80 1.60 11.90 SAND RUBBLE 1 3.70 1.60 11.80 SAND RUBBLE 1 3.70 1.65 12.00 SAND RUBBLE 1 3.50 1.55 10.30 SAND RUBBLE 1 3.50 1.55 10.60 COBBLE 1 3.50 1.50 10.30 COBBLE - ------------------------------------------------------- 4-B-78 ~,Table L~-13-16 •(Conti.nued). ,~ ---------------------------------~---------------------.-DEPTH VELOCITY FLml ~)U i:ST[~\TE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ------------------------------------------------------- 1 3.20 1.50 9.60 COBBLE 1 3.00 1.40 8.40 COBBLE 1 3.10 1.35 8.37 COBBLE 1 3.00 1.55 9.30 COBBLE 1 3.00 1.40 8.40 COBBLE 1 3.00 1.25 7.50 COBBLE 1 3.10 1.30 8.06 COBBLE 1 3.10 1.35 8.37 BOULDER COBBLE 1 2.80 1.10 6.16 COBBLE SAND 1 2.70 1.15 6.21 COBBLE RUBBLE-1 2.90 7.541.30 COBBLE RUBBLE 1 2.70 1.45 7.83 COBBLE RUBBLE 1 2.70 1.55 8.37 COBBLE RUBBLE 1 3.00 1.30 7.80 COBBLE RUBBLE 1 3.00 1.65 9.90 RUBBLE SAND 1 3.00 1.50 9.00 RUBBLE SAND 1 3.10 1.40 8.68 RUBBLE SAND 1 3.10 1.40 8.68 RUBBLE SAND 1 3.00 1.30 7.80 RUBBLE SAND 1 2.60 1.35 7.02 RUBBLE SAND ,~~.....-:...1 2.40 1.40 6.72 RUB~LE SAND 1 2.20 1.50 6.60 RUBBLE SAND 1 2.10 1.40 5.88 RUBBLE SAND ~1 2.00 1.40 5.60 RUBBLE SAND 1 2.00 1.60 6.40 COBBLE 1 2.00 1.30 5.20 COBBLE-1 2.00 1.40 5.60 COBBLE 1 2.00 1.10 4.40 COBBLE 1 1.70 1.40 4.76 COBBLE 1 1.60 .90 2.88 COBBLE 1 1.50 1.00 3.00 COBBLE 1 1.20 1.00 2.40 COBBLE RUBBLE 1 1.40 .90 2.52 COBBLE RUBBLE 1 1.00 .80 1.60 COBBLE RUBBLE 1 1.00 .90 1.80 COBBLE RUBBLE 1 .90 1.00 1.80 COBBLE RUBBLE ,.....1 1.00 1.00 2.00 COBBLE RUBBLE 1 1.40 .60 1.68 COBBLE RUBBLE 1 1.20 .80 1.92 COBBLE RUBBLE 1 1.30 .50 1.30 COBBLE RUBBLE-1 1.00 .90 1.80 COBBLE RUBBLE 1 .70 .50 .70 COBBLE RUBBLE 1 .80 .40 .64 COBBLE RUBBLE-1 .40 .20 .16 COBBLE RUBBLE 1 COBBLE RUBBLE --------------------------------------------------------4-B-79 Table 4-B-16.(Continued).,llOI>l ~'------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ~ TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- 2 .20 .18 .11 RUBBLE SAND 2 .40 .70 1.12 RUBBLE GRAVEL 2 1.00 1.40 5.60 RUBBLE GRAVEL 2 1.40 2.00 11 .20 RUBBLE GRAVEL 2 1.60 2.00 12.80 RUBBLE GRAVEL 2 1.80 2.20 15.80 RUBBLE GRAVEL 2 2.30 2.20 20.20 RUBBLE GRAVEL ..." 2 2.70 2.70 28.30 RUBBLE GRAVEL 2 2.30 3.00 26.80 RUBBLE GRAVEL 2 2.25 2.80 24.40 RUBBLE GRAVEL 2 2.20 2.60 21.70 RUBBLE GRAVEL 2 1.80 2.40 16.40 RUBBLE GRAVEL 2 1.70 2.00 12.90 COBBLE RUBBLE 2 1.50 3.00 14.40 COBBLE RUBBLE 2 1.50 1.60 7.68 COBBLE RUBBLE 2 1.50 2.10 10.10 COBBLE RUBBLE 2 1.60 2.20 11.30 COBBLE RUBBLE 2 1.40 2.30 12.20 COBBLE RUBBLE 2 1.40 1.70 8.57 COBBLE RUBBLE 2 1.20 1.50 6.48 COBBLE RUBBLE 2 1.30 1.80 8.42 COBBLE RUBBLE .~~ 2 1.10 1.70 6.73 COBBLE RUBBLE .; 2 .80 1.40 3.14 COBBLE RUBBLE i -I2.90 1.30 3.28 COBBLE RUBBLE 2 1.00 1.50 4.20 COBBLE RUBBLE 2 1.00 1.10 3.08 COBBLE RUBBLE ! i21.20 .90 3.02 COBBLE RUBBLE ,.."i21.20 1.10 5.28 COBBLE RUBBLE 2 1.20 .90 3.89 COBBLE RUBBLE 2 1.30 .70 3.28 COBBLE RUBBLE 2 1.20 .65 3.12 COBBLE RUBBLE ,.,. 2 1.20 .70 3.36 COBBLE SAND I21.10 .80 3.52 COBBLE RUBBLE 2 1.20 .70 3.36 COBBLE RUBBLE -I21.45 .80 4.64 COBBLE RUBBLE I 2 1.50 .95 5.70 COBBLE RUBBLE 2 1.40 1.15 6.44 COBBLE RUBBLE 2 1.40 1.40 7.84 COBBLE RUBBLE ~ 2 1.50 2.80 10.80 COBBLE RUBBLE 2 1.50 2.10 12.60 COBBLE RUBBLE 2 1.90 1.70 12.90 COBBLE RUBBLE 2 2.00 1.85 14.80 COBBLE RUBBLE 2 2.20 1.90 16.70 COBBLE RUBBLE 2 2.30 1.65 15.20 COBBLE RUBBLE 2 2.10 1.65 13.90 COBBLE RUBBLE ------------------------------------------------------- 4-B-80 - -Table 4-B-16.(Continued). ~,-~ ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (£t)(ft/s)(cfs)PRIHARY SECONDARY ------------------------------------------------------- 2 2.00 1.55 12.40 COBBLE RUBBLE 2 2.00 1.70 13.60 COBBLE RUBBLE 2 2.10 1.30 10.90 COBBLE RUBBLE-2 2.10 1.20 10.10 COBBLE RUBBLE 2 2.00 .95 7.60 COBBLE RUBBLE 2 1.50 .73 4.38 BOULDER RUBBLE-2 1.50 .50 3.00 BOULDER RUBBLE 2 1.45 .35 2.03 SILT BOULDER 2 1.40 .40 2.24 SILT BOULDER 2 .50 0.00 0.00-3 .50 .10 .07 RUBBLE SILT 3 1.30 .35 .91 SILT 3 1.60 .55 1.76 SILT "....3 1.60 .50 1.60 SILT 3 1.80 .60 2.16 SILT 3 2.00 .60 2.40 SILT -~3 2.00 .61 2.44 SILT 3 2.20 .80 3.52 SILT RUBBLE 3 1.80 .92 6.62 COBBLE SILT 3 2.20 .96 8.45 COBBLE SILT_.-3 2.45 1.30 12.70 COBBLE SILT 3 2.35 1.15 10.80 COBBLE SILT 3 2.50 1.15 11.50 COBBLE SILT 3 2.75 1.28 14.10 COBBLE SILT 3 2.60 1.10 11.40 SILT 3 2.60 1.48 15.40 RUBBLE GRAVEL-3 2.60 1.10 11.40 RUBBLE GRAVEL 3 1.00 1.50 6.00 BOULDER 3 2.40 1.10 10.60 RUBBLE SILT 3 2.20 1.15 10.10 RUBBLE SILT-3 2.20 .90 7.92 RUBBLE SILT 3 2.10 .90 7.56 RUBBLE SILT 3 1.60 .80 5.12 RUBBLE SILT 3 1.40 .80 4.48 COBBLE SILT 3 .75 .38 1.14 COBBLE SILT 4 SAND-4 .10 0.00 0.00 SAND 4 1.40 .30 1.68 SAND 4 1.50 .30 1.80 SAND 4 1.60 .70 4.48 SAND 4 1.75 .75 5.25 SAND 4 1.50 .85 5.10 SAND 4 1.60 1.10 7.04 SAND-4 1.70 1.40 9.52 SAND 4 1.85 1.45 10.70 SAND ---------------~--------------------------------------- 4-B-81 -Table 4-B-16.(Continued). ~ --------------------------------------------------------DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY --------------------------------------------------------6 1.30 1.80 9.36 GRAVEL RUBBLE 6 1.30 1.70 8.84 GRAVEL RUBBLE 6 1.40 2.40 13.40 GRAVEL RUBBLE-6 1.50 2.10 12.60 GRAVEL RUBBLEI I 6 1.90 2.05 15.60 GRAVEL RUBBLE 6 1.80 2.40 17.30 GRAVEL RUBBLE ~6 1.40 1.50 8.40 GRAVEL RUBBLE 6 1.60 .90 5.76 GRAVEL RUBBLE 6 1.10 .70 3.08 GRAVEL RUBBLE 6 1.10 .50 2.20 BOULDER COBBLE 7 .30 .55 4.79 SAND 7 .50 .70 1.40 SAND GRAVEL 7 1.20 1.20 5.76 SAND GRAVEL 7 .70 1.40 3.92 GRAVEL SAND 7 .70 1.55 4.34 GRAVEL SAND 7 .70 1.50 4.20 GRAVEL SAND 7 .90 1.80 6.48 GRAVEL SAND 7 .90 1.80 6.48 GRAVEL 7 1.20 2.00 9.60 GRAVEL 7 1.40 1.90 10.60 GRAVEL RUBBLE 7 2.10 1.70 14.30 7 2.40 2.45 23.50 COBBLE RUBBLE 7 2.45 2.50 24.50 COBBLE RUBBLE ,-7 2.50 1.95 19.50 COBBLE RUBBLE 7 1.90 .75 5.70 COBBLE RUBBLE ------------------------------------------------------- ~/Summarized in Appendix Table 4-B-5. - 4-B-83 l""'- I -, Table 4-B-17.Hydraulic habitat variables~/collected in Slough 21 ,Sep 19,1982.-at transects Af/fl" ------------------------------------------------------- DEPTH VELOCITY FLOW SUBSTRATE ~ TRANSECT (ft)(ft/s)(cfs)PRIMARY SECONDARY ------------------------------------------------------- ~ 1 .20 0.00 0.00 SAND SILT 1 .30 0.00 0.00 SAND SILT 1 .45 0.00 0.00 SAND SILT 1 .75 .05 .15 SAND SILT ~ 1 .95 .05 .19 SAND SILT 1 1.10 .10 .44 SAND SILT 1 1.60 0.00 0.00 SAND RUBBLE 1 1.65 0.00 0.00 SAND RUBBLE 1 1.70 0.00 0.00 SAND'SILT 1 1.90 0.00 0.00 SAND SILT .....1 2.00 0.00 0.00 SAND SILT 1 2.20 .05 .44 SAND SILT 1 2.40 0.00 0.00 SAND RUBBLE 1 2.30 .05 .46 SAND COBBLE -1 2.30 .10 .92 SAND COBBLE 1 2.10 .15 1.26 RUBBLE GRAVEL 1 1.80 .10 .72 RUBBLE GRAVEL ~ 1 1.80 .10 .72 COBBLE RUBBLE 1 1.70 .15 1.02 COBBLE RUBBLE 1 1.70 .10 .68 RUBBLE COBBLE 1 1.40 .10 .56 BOULDER COBBLE --I 1.40 .15 .84 COBBLE RUBBLE 1 1.70 .15 1.02 COBBLE RUBBLE 1 1.90 .10 .76 COBBLE RUBBLE 1 1.60 .05 .32 RUBBLE SAND 1 1.00 '0.00 0.00 COBBLE 1 1.20 0.00 0.00 COBBLE SAND ~ 1 .50 0.00 0.00 BOULDER COBBLE 1 .80 0.00 0.00 COBBLE RUBBLE 1 .50 0.00 0.00 COBBLE RUBBLE 1 .20 0.00 0.00 COBBLE RUBBLE ~: 1 .20 0.00 0.00 BOULDER COBBLE 2 .05 0.00 0.00 RUBBLE GRAVEL 2 .10 0.00 0.00 RUBBLE GRAVEL ~ 2 .40 0.00 0.00 RUBBLE GRAVEL 2 .80 0.00 0.00 RUBBLE GRAVEL 2 .95 0.00 0.00 COBBLE RUBBLE -2 1.00 0.00 0.00 COBBLE RUBBLE 2 .80 0.00 0.00 COBBLE RUBBLE 2 .55 0.00 0.00 RUBBLE GRAVEL 2 .35 0.00 0.00 COBBLE RUBBLE 2 .30 0.00 0.00,COBBLE RUBBLE 2 .20 0.00 0.00 COBBLE RUBBLE 2 .20 0.00 0.00 RUBBLE GRAVEL ------------------------------------------------------- 4-B-84 ~ ~ Table 4-B-l7.(Continued). ~ -------------------------------------------------------pP'" DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(efs)PRIMARY SECONDARY ~ ---------------~--------------------------------------- 3 1.45 .15 .44 SILT GRAVEL ~1 3 1.20 .15 .36 SILT BOULDER 3 1.25 .18 .45 SILT 3 1.30 .20 .52 RUBBLE GRAVEL 3 1.10 .05 .11 RUBBLE SILT -3 1.40 .22 .62 RUBBLE 3 1.30 .20 .52 RUBBLE 3 1.30 .13 .34 RUBBLE -. 3 1.20 .18 .43 SILT RUBBLE 3 1.10 .15 .33 SILT RUBBLE 3 1.05 .18 .38 SILT RUBBLE 3 1.20 .16 .38 SILT COBBLE 1tfm1) 3 1.30 .14 .36 COBBLE RU:BBLE 3 1.00 ..10 .20 SILT COBBLE 3 1.10 .10 .22 SILT COBBLE 3 .90 .10 .18 SILT COBBLE 3 .80 .01 .02 COBBLE SILT 3 .40 0.00 0.00 COBBLE SILT 3 .30 0.00 0.00 COBBLE SILT 3 .20 0.00 0.00 COBBLE SILT 4 .15 .05 .02 SILT 4 .20 .07 .03 SILT ~-, 4 .20 .03 .01 SILT 4 .30 0.00 0.00 SILT 4 .45 0.00 0.00 SILT ",""" 4 .50 .05 .05 SILT 4 .40 0.00 0.00 SILT 4 .25 .02 .01 SILT I"\l14.25 .05 .03 SILT 4 .30 .08 .05 SILT 4 .40 .10 .08 SILT 4 •50 .10 .10 SItT ~ 4 .45 .15 .14 SILT 4 .50 .16 .16 SILT 4 .65 .21 .27 SILT ,~ 4 .80 .23 .37 SILT 4 1.05 .21 .44 SILT 4 1.20 .20 .48 SILT 4 .52 SILT -1.30 .20 4 1.40 .20 .56 SILT 4 1.50 .19 .57 SILT 4 1.75 .15 .53 SILT 4 2.00 .15 .60 SILT 4 2.30 .19 .87 SILT 4 2.60 .18 .94 SILT --------------------------------~---------------------- 4-B-86 ""'!! - '"""\ Table 4-B-17.(Continued)• ,.",., -------------------------------------------------------,#W' DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft/s)(ds)PRIMARY SECONDARY ~ ------------------------------------------------------- 6 .20 .40 .16 RUBBLE COBBLE 6 .20 .38 .12 RUBBLE COBBLE 6 .40 1.30 1.04 RUBBLE COBBLE 6 .45 '1.75 1.58 RUBBLE COBBLE 6 .70 2.10 2.94 RUBBLE COBBLE """6 .65 1.20 1.56 RUBBLE COBBLE 6 .70 .50 •70 RUBBLE COBBLE 6 .60 .50 .60 RUBBLE COBBLE 6 .40 .38 .30 RUBBLE COBBLE 6 .40 .20 .16 RUBBLE COBBLE 6 .30 .60 .36 RUBBLE COBBLE 6 .10 .05 .0.1 RUBBLE COBBLE ~ 6 .10 0.00 0.00 BOULDER RUBBLE 6 .10 0.00 0.00 BOULDER RUBBLE 7 .10 0.00 0.00 GRAVEL RUBBLE -7 .20 .12 .05 GRAVEL RUBBLE 7 .30 .20 .12 GRAVEL RUBBLE 7 .50 .29 .29 GRAVEL RUBBLE ..... 7 .90 .35 •63 COBBLE RUBBLE 7 1.00 .38 .76 COBBLE RUBBLE 7 1.00 .32 .64 COBBLE RUBBLE 7 1.30 .55 1.43 COBBLE RUBBLE !""""""~ 7 1.60 .55 1.76 COBBLE RUBBLE 7 1.65 .50 1.65 COBBLE RUBBLE 7 1.50 .35 1.05 RUBBLE BOULDER -7 1.50 .20 .60 BOULDER RUBBLE 7 .50 .25 .25 BOULDER RUBBLE 8 •80 •75 .96 GRAVEL RUBBLE -8 .80 .35 .48 GRAVEL RUBBLE 8 .70 .20 .24 GRAVEL 8 1.00 .01 .02 GRAVEL 8 1.10 .10 .09 GRAVEL 8 1.20 .10 0.00 GRAVEL 8 1.20 .11 0.00 GRAVEL 8 1.10 .11 0.00 GRAVEL 8 1.10 .10 0.00 GRAVEL 8 1.10 .10 0.00 GRAVEL 8 1.25 .08 0.00 SAND GRAVEL 8 1.30 .10 0.00 SAND GRAVEL """', 8 1.35 .12 0.00 SAND 8 1.30 .12 0.00 SAND GRAVEL 8 1.30 .08 0.00 SAND GRAVEL -8 1.30 .08 0.00 SAND GRAVEL 8 1.40 .15 0.00 SAND GRAVEL 8 1.70 .15 0.00 SAND GRAVEL ------------------------------------------------------- 4-B-88 ~ - ....Tab 1 e '~-B-17 •(Continued). ~------------------------------------------------------- ~DEPTH VELOCITY FLOW SUBSTRATE TRANSECT (ft)(ft!s)(cis)PRIMARY SECONDARY ------------------------------------------------------- ..-8 1.70 .15 0.00 SAND GRAVEL 8 1.80 .15 0.00 SAND GRAVEL 8 1.95 .15 0.00 SAND GRAVEL 8 2.00 .12 0.00 SAND 8 2.10 .12 0.00 SAND 8 2.30 .10 0.00 SAND 8 2.40 .28 0.00 SAND 8 2.35 .01 0.00 SAND 8 2.20 .08 0.00 SAND 8 2.10 .05 0.00 SAND BOULDER 8 2.10 .10 0.00 SAND 8 1.90 .12 0.00 SAND 8 1.80 .10 .34 SAND 8 2.80 .30 1.60 SAND 8 1.50 .05 .14 SAND 8 1.40 .15 .39 SAND 8 ·1.30 .10 .24 SANDrm-8 1.20 .20 .36 SAND 8 1.30 .10 .18 SAND 8 1.60 .35 .78 SAND r-"'-.8 1.50 .15 .14 SAND 8 1.40 .25 .21 SAND 8 1.45 .22 .13 SAND,..8 1.20 .42 0.00 SAND 8 1.20 .30 0.00 SAND 8 .80 .40 0.00 SAND 8 1.20 .10 .02 SAND-8 1.00 .20 .04 SAND 8 .85 .15 .03 SAND 8 .~O .20 .08 SAND 8 .75 .15 1.80 SAND 8 1.15 .30 .55 SAND 8 1.10 .32 .68 SAND 8 1.50 .30 .87 SAND COBBLE 8 1.10 .32 .68 GRAVEL RUBBLE 8 1.80 .30 1.08 BOULDER RUBBLE 8 .70 .20 .28 SAND,.... ------------------------------------------------------- 2.-/Summarized in Appendix Table 4-B-5. - - 4-B-89 Appendix Table 4-S-18.--Depths (ft)and velocitie5 (ft/sec)associated with chum salmon redds in four sloughs at three discharges (0.cfs)in 1982. Depth Velocity o *0**03***Average 01*O2**03***Average12 Slough 8A -0.67 0.72 0.70 0.03 0.36 0.30x Range 0.30-1.30 0.20-1.60 0.20-1.60 0.00-1.45 0.05-0.72 0.00-1.45 N 26 11 37 26 11 37 o (cfs)4 7 4 7 Slough 9 -1.24 1.27 1.25 0.13 0.16 0.14x Range 0.30-2.40 0.40-2.10 0.30-2.4 0.05-0.40 0.00-0.78 0.00-0.78 N 28 20 48 28 20 48o(cfs)3 8 3 8 +:=> I co 1 ~28 0.13ISlough11x1.21 1.3.3 0.45 .32 1..0 Range 0~60,-2.20 0.55-2.10 .5'5"2'.20 0.00-0.61 0.05-1.00 0.00-1.000 N 6 9 15 6 9 15o(cfs) -xSlough21Range No(cfs) *01 =25-26 August **02 =2-7 September ***03 =20 September 1.02 0.40-2.60 33 5 1.02 0.40-2.60 33 0.22 0.00-1.10 33 5 0.22 0.00-1.10 33 ~•" )i J I ..I .1 1 J j J ~j ~J B )J J .1 J"it!> 1 1 J 1 }1 J I I 1 J )1 ) } 1 ) Table 4-6-19.Depths (ft)and velocities (ft/sec)associated with pink salmon and sockeye salmon redds in three sloughs at three discharges (0,cfs)in 1982. PINK SALMON Slough 8A -x Range N ° 01* 0.30 1 4 Depth °2**°3*** 0.30 1 4 °1* O.BO 1 4 Velocity °2**°3***Average O.BO 1 4 Slough 11 -x Range N o 0.85 1.51 0.75-2.80 22 1.48 0.75-2.80 23 0.00 0.23 0.00-0.80 22 .22 0.00-0.80 23 *01 ~25-26 August **02 =2-7 September ***03 ~20 September Table 4-B-20.Hydraulic habitat variables collected at chum redds.(Transect number indicates the transect area in which the redd was located). -------------------~------------------------'----------------------------------------------------- INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERATURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft)(ft/s)PRIMARY SECONDARY (OC)(OC)NUMBER ------------~------------------------------------------------------------------------------------ SLOUGH 8A 820826 Oc .50 1.45 GRAVEL RUBBLE 11.4 12.6 C03 SLOVGH 8A 820826 Oc .80 0.00 GRAVEL RUBBLE 11.2 13.0 CO2 SLOUGH 8A 820826 OC .40 .10 GRAVEL RUBBLE 13.2 C04 SLOUGH 8A 820826 Oc .30 .05 GRAVEL RUBBLE 13.2 CIS SLOUGH 8A 820826 OC..•40 .05 GRAVEL RUBBLE 13.2 C14 SLOUGH 8A 820826 OC .50 .10 GRAVEL COBBLE 12.8 CD SLOUGH 8A 820826 OC 1.00 .1"0 GRAVEL RUBBLE 13.2 cn SLOUGH 8A 820826 OC 1.10 .ro GRAVEL RUBBLE 13'.2 C09 SLOUGH 8A 820826 Oc 1.10 .10 GAAVEL RUBBLE 13.2 COB SLOUGH 8A 820826 Oc 1.10 •.10 GRAVEL RUBBLE 13.2 C07 ~SLOUGH 8A 820826 OC 1.00 .·10 GRAVEL RUBBLE 13.1 CObI o:l SLOUGH 8A 820826 OC .60 .1'5 GMNEU ltUmni.E 13.0 COS,. \0 SLOUCH 8A 820826 OC .60 .1.0,GRAW'EL RtlBBLE 13 .2 CIaN SLOUGlf 8A 820826'oc .90 .10 GRAVEL RuaBLE 13.0 COl SLOUGH 8A 820826 oc .40 .10 GRAVEL RUBBLEl 13.0 C12 SLOUGH 8A 820826 BC .30 .03 GRAVEL RUBBLE 12.4 cn SLOUGH 8A 820826 BC .50 0.00'GRAVEl;RUBBLE 12.4 C21 SLOUGH 8A 820826 BC .45 1.05 GRAVEL RUBBLE 12.4 e16 SLOUGH 8A 820826 Be .50 .55 RUBBLE GRAVEL 12.4 C18 SLOUGH 8A 820826 BC .45 .75 RUBBLE GRAVEL 12.0 cn SLOUGH 8A 820826 BC .30 .72 GRAVEL RUBBLE 12.4 C19 SLOUGH 8A 820826 BC .35 .05 RUBBLE GRAVE"L C23 SLOUGH 8A 820826 BC .40 .90 RUBBLE GRAVEL 12.0 C2A SLOUGH 8A 820826 BC 1.30 .18 RUBBLE GRAVEL 12.0 C25 SLOUGH 8A 820826 Be 1.05 .18 RUBBLE GRAVEL 11.5 C26 SLOUGH 8A 820826 BC 1.00 .19 RUBBLE GRAVEL 11.0 C27 -------.,oi --._..._,-__ ~,~ j ••)..)i I J I J I )J it J ,J ~1 ~J J I i J )-- ~J 1 1 )i J 1 »( )) Table 4-B-20.(Continued). -------~------~~--------------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERA TURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft)(ft/s)PRIMARY SECONDARY (0 C)(oC)NUMBER ------------------------------------------------------~------------------------------------------ SLOUGH 8A 820906.1.60 .10 GRAVEL RUBBLE 7.6 C40 SLOUGH 8A 820906 1.00 .05 GRAVEL RUBBLE 5.1 7.6 C41 SLOUGH 8A 820906 .60 .30 GRAVEL RUBBLE 6.7 7.6 C42 SLOUGH 8A 820906 .80 .33 RUBBLE GRAVEL 4.9 7.6 C43 SLOUGH 8A 820906 .70 .20 GRAVEL COBBLE 6.1 7.6 C44 SLOUGH 8A 820906 .60 .65 RUBBLE COBBLE 7.6 C45 SLOUGH 8A 820906 .50 .45 GRAVEL RUBBLE 4.9 7.6 C46 SLOUGH 8A 820906 .20 .20 RUBBLE GRAVEL 5.7 7.6 C47 SLOUGH 8A 820906 .70 .40 GRAVEL RUBBLE 6 .9 7.6 C48 SLOUGH 8A 820906 .90 .55 RUBBLE COBBLE 5.2 7.6 C49 .j:::>SLOUGH 8A 820906 .40 .72 GRAVEL RUBBLE 7 .6 C50I o:J I ...0 SLOUGH 9 820825 02 8.8 COlw SLOUGH 9 820826 02 .60 .40 COBBLE GRAVEL 3.8 8.2 COl SLOUGH 9 820826 02 .80 .10 .COBBLE GRAVEL 4.0 7.6 CO2 SLOUGH 9 820826 02 .70 .10 COBBLE GRAVEL 3.4 7.6 C03 SLOUGH 9 820826 02 .90 .05 COBBLE GRAVEL 4.2 7.8 C04 SLOUGH 9 820826 02 COBBLE GRAVEL COS SLOUGH 9 820826 01 1.10 .10 RUBBLE GRAVEL 3.9 8.8 C06 SLOUGH 9 820826 01 .75 .10 COBBLE GRAVEL 4.8 9.8 C27 SLOUGH 9 820826 01 1.90 .05 COBBLE GRAVEL 4.4 8.8 C26 SLOUGH 9 820826 01 1.90 .05 RUBBLE GRAVEL 4.5 9.4 C07 SLOUGH 9 820826 01 1.80 .10 GRAVEL RUBBLE 5.2 9.8 C08 SLOUGH 9 820826 01 1.25 .10 COBBLE GRAVEL 4.3 9.4 C09 SLOUGH 9 820826 01 1.30 .10 GRAVEL RUBBLE 4.7 9.2 C10 ----------------------------------------------------------------------------~-------------------- Table 4-B-20.(Continued). ----------~-------------------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERATURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft)(ft/s)PRIMARY SECONDARY (°C)(°C)NUMBER --~----~--------~-------------------------------------------------------------------------------- SLOUGH 9 820826 01 1.40 .10 COBBLE GRAVEL 4.7 9.4 Cll SLOUGH 9 820826 01 1.50 .10 RUBBLE GRAVEL 6.0 9.2 C12 SLOUGH 9 820826 01 1.70 .15 GRAVEL RUBBLE 5.4 9.4 C13 SLOUGH 9 820826 01 1.10 .15 RUBBLE GRAVEL 4.0 9.2 C14 SLOUGH 9 820826 01 1.10 .15 RUBBLE GRAVEL 4.5 9.2 CIS SLOUGH 9 820826 01 1.30 .20 RUBBLE GRAVEL 4.5 9.6 C16 SLOUGH 9 820826 01 .70 .10 COBBLE GRAVEL 5.4 10.0 C17 SLOUGH 9 820826 Oc 1.70 .15 RUBBLE GRAVEL 3.9 11.0 C19 SLOUGH 9 820826 OC 1.80 .10 BOULDER COBBLE 3.5 10.2 C20 SLOUGH 9 820826 OC 1.50 .10 COB'BLE RUBBLE 4.0 9.6 C21 .j::o SLOUGH 9 820826 OC 2.40 .10 COBBLE GRAVEL 4.4 10.4 G22 I SLOUGH 9 820826 OC 1.40 .15 COBBLE GRAVEL 6.3 10.1 C25o:J I \.0 820905 C46.pi'SLOUGH 9 1.70 0.00 GRAVEL RUBBLE 8.2 8.7 SLOUGH 9 820905 2.10 .02 GRAVEL RUBBLE 8.2 8.9 C47 SLOUGH 9 820905 2.10 .02 GRAVEL RUBBLE 7.8 8.9 C28 SLOUGH 9 820905 1.20 .10 COBBLE RUBBLE 6.4 8.8 C29 SLOUGH 9 820905 1.30 .11 COBBLE RUBBLE 5.9 8.6 C30 SLOUGH 9 820905 1.00 .08 RUBBLE COBBLE 6.0 8.8 C31 SLOUGH 9 820905 1.05 .11 RUBBLE .COBBLE 6.1 8.8 C32 SLOUGH 9 820905 1.30 .10 COBBLE RUBBLE 6.1 8.9 C33 SLOUGH 9 820905 1.30 .10 RUBBLE COBBLE 7.0 9.0 C34 SLOUGfl 9 820905 1.30 .05 COBBLE RUBBLE 6.1 8.8 C3S SLOUGH 9 820905 .75 .17 GRAVEL RUBBLE 4.6 8.4 C36 SLOUGH 9 820905 .50 .41 GRAVEL RUBBLE 5.S 8.8 C37 SLOUGH 9 820905 .40 .78 GRAVEL RUBBLE 4.2 8.8 C38 SLOUGH 9 820905 1.80 .14 RUBBLE GRAVEL 9.0 C39 ------------------------------------------------------------------------------------------------- l ~ J J ~~J I ))J I ~)J J I t J i'J ] 1 1 ))·1 1 1 J J 1 1 )) Table 4-B-20.(Continued). ---------------------------------.---------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERATURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft )(ft!s)PRIMARY SECONDARY (OC)(OC)NUMBER ------------------------------------------------------------------------------------------------- SLOUGH 9 820905 1.60 .21 RUBBLE GRAVEL 9.0 C40 SLOUGH 9 820905 1.25 .22 RUBBLE COBBLE 8.8 C41 SLOUGH 9 820905 1.25 .14 COBBLE GRAVEL 8.6 C42 SLOUGH 9 820905 1.40 .20 COBBLE GRAVEL 8.6 C43 SLOUGH 9 820906 1.10 .20 GRAVEL COBBLE 7 .0 C44 SLOUGH 9 820906 1.00 .11 GRAVEL COBBLE 6.6 C45 SLOUGH 11 820905 .60 .15 GRAVEL RUBBLE 5.0 7 .1 SLOUGH 11 820905 .70 .61 GRAVEL RUBBLE 6.1 7.0 SLOUGH 11 820905 .80 0.00 RUBBLE GRAVEL 7.0 +:0 SLOUGH 11 820905 2.20 0.00 GRAVEL COBBLE 4.3 6.8I OJ SLOUGH 11 820905 .85 0.00 COBBLE RUBBLE 4.3 6.8I '.0 SLOUGH 11 820905 2.10 0.00 COBBLE GRAVEL 4.1 7.0(Jl SLOUGH 11 820920 1.45 .12 COBBLE GRAVEL 4.6 COl SLOUGH 11 820920 2.10 .20 GRAVEL RUBBLE 4.3 CO2 SLOUGH 11 820920 2.05 .05 GRAVEL RUBBLE 4.9 C03 SLOUGH 11 820920 1.20 .45 GRAVEL RUBBLE 4.5 C04 SLOUGH 11 820920 1.35 .70 GRAVEL RUBBLE 4.4 COS SLOUGH 11 820920 .90 .75 GRAVEL RUBBLE 5.0 C06 SLOUGH 11 820920 .60 1.00 GRAVEL RUBBLE C07 SLOUGH 11 820920 .55 .70 GRAVEL COBBLE 5.5 C08 SLOUGH 11 820920 1.80 .09 GRAVEL COBBLE 3 .1 C09 SLOUGH 21 820903 08 1.00 0.00 GRAVEL RUBBLE 5.5 6.6 001 SLOUGH 21 820903 08 1.15 0.00 GRAVEL RUBBLE 4.9 6.3 002 ----~--------------------------------------------------~-----------------------------------~---~~~ Table 4-B-20.(Continued). INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERATURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft)(it/s)PRIMARY SECONDARY (oC)(oC)NUMBER --------------------------------------------------------------,----------------------------------- SLOUGH 21 820903 08 1.40 0.00 GRAVEL RUBBLE 4.7 6.3 003 SLOUGH 21 820903 08 2.00 .43 BOULDER COBBLE 4.5 5.1 004 SLOUGH 21 820903 07 1.30 0.00 RUBBLE COBBLE 5.0 5.5 005 SLOUGH 21 820904 08 L10 0.00 BOULDER COBBLE 4.7 7.4 006 SLOUGH 21 820904 08 1.50 0.00 BOULDER COBBLE 4.8 7.2 007 SLOUGH 21 820904 08 1.10 .17 RUBBLE GRAV.EL 4.7 7.5 009 SLOUGH 21 820904 07 .90 .23 RUBBLE COBBLE 4.9 7.4 010 S.LOUGH 21 820904 07 .70 0.00 RUBBLE COBBLE 5.6 7.2 011 SLOUGH 21 820904 07 .50 0.00 COBBLE GRAVEL 5.5 7.4 012 SLOUGH 21 820904 07 .60 0.00 .RUB BLE GRAVEL 5.5 7.2 013 +'0 SLOUGH 21 820904 07 1.20 .27 RU:B'BLE GRAVEL 4.6 7.3 014I. OJ SLOUGH 21 820904 07 .45 .57 .RUBBLE 4.7 7.3 015I \C SLOUGH 21 820·904 04 1•.10 0.00 GRAVEL COBBLE 4.6 7.6 016.C1'l SLOUGl:!.21 820904 04 .70 .•36 GRAVEL RUBBLE 4.8 7.4 017 SLOUGH 21 820904 04 1.00 .58 RUBBLE COBBLE 4.5 7.3 018 SLOUGH 21 820904 04 1.00 .53 GRAVEL RUBBLE 4.7 7.3 019 SLOUGH 21 820904 04 1.80 .10 GRAVEL RUBBLE 5,.2 7.4 020 SLOUGll 21 .820904 04 1.20 0.00 GRAVEL COBBLE 4.6 7.3 022 SLOU.GH 21 820904 04 2.60 .02 SAND GRAVEL 4.3 7.3 021 SLOUGH 21 820904 03 1.15 .11 COBBLE RUBBLE 4.2 7.5 023 SLOUGH 21 820904 03 .95 .16 COBBLE GRAVEL 4.6 7.4 024 SLOUGll 21 820904 03 1.00 .19 CO B:BLE GRAVEL 4.7 7.5 015 SLOUGH 21 820904 03 .60 .40 RUBBLE GRAVEL .4.6 7.4 026 SLOUGH 21 820904 03 .70 .31 COBBLE GRAVEL 4.9 7.3 027 SLOUGH 21 820904 03 .70 .46 COBBLE GRAVEL 4.2 7.3 028 SLOUGH 21 820904 02 .50 loU COBBLE GRAVEL 4.4 7.5 029 ...---..--~----~-----~------"'-:--..---..---------,-,_._---------------.--------_._--------_.__._~---_.__._------_._.--- \, J J ,J J J J .1 I .~J )I J "I J ;1 -I=» I o:;J I 1..0. --.J '-1 1 --,}1 ]1 ]]-.1 1 1 J '))'~j T~b1e 4-B-20.(Continued). ------------------------------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERATURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft)(ft/s)PRIMARY SECONDARY (OC)(OC)NUMBER ----------------------------------------------------------------------------------------------~--- SLOUGH 21 820904 02 .65 .44 BOULDER COBBLE 4.0 7.5 030 SLOUGH 21 820904 01 .40 .35 COBBLE RUBBLE 4.4 7 .5 031 SLOUGH 21 820904 01 .85 .40 RUBBLE GRAVEL 4.4 7.6 032 SLOUGH 21 820904 01 1.10 .12 COBBLE GRAVEL 4.7 7.6 033 SLOUGH 21 820904 01 .85 0.00 COBBLE RUBBLE 4.8 8.7 034 Table 4-B-21.Hydraulic habitat variables collected at sockeye redds.(Transect number indicates the transect area in which the redd was located). ------------------------------------------------------------------------------------------------- INTRAGRA VEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERA TURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft )(ft/s)PRIMARY SECONDARY (DC)(°C)NUMBER -------------------------------------------------------------------------~----------------------- SLOUGH 8A 820906 .50 .05 GRAVEL SAND 7.4 7.6 SOl SLOUGH 11 820905 .85 0.00 COBBLE GRAVEL 5.3 6.8 SLOUGH 11 820920 2.80 .09 GRAVEL RUBBLE 3.1 SOl SLOUGH 11 820920 2.80 .07 GRAVEL RUBBLE 4.1 502 SLOUGl1 11 820920 2.50 .08 GRAVEL·RUBBLE 3.2 503 SLOUGH 11 820920 2.50 0.00 GRAVEL 3.4 504 SLOUGH 11 820920 2.60 .01 GRAVEL 3.1 50S SLOUGH 11 820920 1.80 .06 GRAVEL RUBBLE 3.2 506 ~SLOUGH 11 820920 2.10 .08 GRAVEL RUBBLE 3.2 507IcoSLOlJGl111820920.75 .05 GRAVEL RUBBLE 4.0 S08I \0 SLOUG}I 11 820920 1.00 .45 GRAVEL COBBLE 4.2 S09CO SLOUGB.11 820920 1.15 .40 GRAVEL BOULDER 3.0 510 SLOUGH 11 820920 1.15 .70 RUBBLE COBBLE 3.1 Sl1 SLOUGH 11 820920 .50 .50 GRAVEL SAND 3.0 S12 SLOUGH 11 820920 1.10 .80 GRAVEL COBBLE 3.6 813 SLOUGH 11 820920 .95 .06 RUBBLE GRAVEL 3.5 S14 SLoUGH 11 820920 1.25 .10 RUBBLE GRAVEL 3.1 SIS SLOUGH 11 820920 1.30 .30 RUBBLE GRAVEL 3.2 516 SLOUGH 11 820920 1.20 .04 GRAVEL RUBBLE 3.2 S17 SLOUGH 11 820920 ..85 .10 GRAVEL COBBLE 3.2 S18 SLOUGH 11 820920 .90 .30 GRAVEL SAND 3.4 S19 SLOUGH 11 820920 1.00 .30 RUBBLE GRAVEL 3.4 S20 SLOUGH 11 820920 1.55 .19 GRAVEL SAND 3.0 S21 SLOUCH 11 820920 1.45 .28 SAND GRAVEL 3.2 S22 --.--~.-~~-----------~-~~-------------~---~----------------------------------------,--------~----- l \ ,I I ,I I J J J ,J I J J ~)J I J I I 1 J 1 1 ).J -1 J )»J 1 )) Table 4~B-21.(Continued). -------------------------------------~----------------------------------------------------------- INTRAGRAVEL SURFACE WATER DEPTH VELOCITY SUBSTRATE TEMPERATURE TEMPERATURE REDD LOCATION DATE TRANSECT (ft)(ft/s)PRIMARY SECONDARY (DC)(OC)NUMBER ------------------------------------------------------------------------------------------------- -+::> I OJ I \0 \0 SLOUGH 21 820904 08 1.50 .27 COBBLE GRAVE+.4.8 7.5 008 Table 4-B-22.Hydraulic habitat variables collected at pink redds.(Transect number indicates the transect area in which the redd was located). -------------------------------------------------------------'------------------------_._---_._-------- LOCATION DATE TRANSECT DEPTH (it ) VELOCITY (ftls) INTRAGRAVEL SUBSTRA TE TEMPERATURE PRIMARY SECONDARY (Oe) SURFACE WATER TEMPERATURE REDD (°C)NUMBER .j:S I OJ I..... o·o -------_._------------....,------.-----------_.__._-----------------------------------------_._'--------_._-- SLOUGH 8A 820826 OC .30 .80 GRAVEL RUBBLE 13.0 POI SLOUGH 9·820825 06 .80 .20 GRAVEL RUBBLK 11.0 10.0 P02 SLOUGH 9 820825 06 .55 .30 GRAVEL RUBBLE 11.1 10.0 P03 _....__.._...-.-_._----------_._---<_._----_....._--------,_._--,---'_....-'_.--.__.__.._-----.__._------------_._._--_._-'._---_._------ }, J I J J J J J I J J I J I j - ,,~ APPENDIX C TEMPERATURE DATA This appendix includes an index of continuous temperature data collected in the Susitna River basin,1981-1982,(pp 4-C-2 to 4-C-6);a complete summary of continuous surface water temperatures collected during the open water season in mainstem,sloughs,and tributaries (pp.4-C-7·to 4-C-94);weekly water temperatures calculated from the mainstem,slough and tributary data (4-C-95 to 4-C-118);continuous intragravel and surface water temperatures collected during the open water season in sloughs (pp.4-C";'119 to 4-C-221);summaries of continuous surface and intragravel water temperatures collected during the ice-covered season in sloughs (pp.4-C-222 to 4-C-260);weekly water temperatures calculated from the surface and intragravel data (4-C-261 to 4-C-271); and instantaneous intragravel and surface water temperatures in sloughs collected during the open water season at salmon redds (pp.4-C-272 to 4-C-276).These data were collected during the open water and ice-covered seasons in the study area located within the Cook Inlet to Oshetna reach of the Susitna River.Instantaneous surface water temperature data collected during the ice-covered season,not included in this summary,are located in Appendix J. 4-C-l Appendix Table 4-C-1.ADF&C Susitna River Basin continuous temperature dota index,1981-1982."""'- ==::::;==::::;::::=::::===:::::::====::::::::::::::::==================-,DATA SOURCE Location Alexander Creek Tributary RM 10.1 TRM 0.5 S15N07W05CBC Mainstem -above Alexander Creek RM 10.1 S15N07W05CDB Mainstem at Su Station RM 25.8 S17N07W22DCD 1981 Final Draft Pl,'lriod of R~port Vol.2 1983 Draft Basic Instru~nt Record Part I Data Report Vol.4_ Surface water 06/06/81-10/09/81 X Thermograph Surfece water 06/06/81-09/01/81 X Thel"mograph Surface water 05/16/82-06110182 X Thermograph Yentna Ri vel" Tributary RM 28 TRM 4.0 S18N07W34DBC TRM 2.0 S17N07W01 CAB 1982 1981 51,1r f acewater Thermoqr a p,h 06/05/81-09/14/81 06/08/82-09/27/82 10/04/82-10/11/62 X X X Mainstem -above Yentna River RM 29.5 1982 S17N06W07CAD RM 32.3 1981 S17N06W07CDB Surface water Thermograph 06106/81-10/09181 06/08/82-06/14182 06/18/82-10/17/82 X x X Deshka River Tributary RM 40.6 TRM 1.2 S19N06W26CBB Surface water o6/l0/(n-10/~/81 Thermopraph X Surface water 06/24/61-09/30/81 Thermograph Li tt1e Wi 1low C['eek Tributary RM 50.5 TRM 1.a S20N05W23CBC Mainstem -above Little ~illow Creek RM 50.5 S20N05W27BAC Sl,Irface water Thermograph 06l24/81-09/09/81 Q9IlS181-09!29/81 x x X - Mainstem -above Kashwitna River RM 61.2 S21N05W13ABA Surface water o8/30/81-09127/8J The,.mograph x Montana Creek Tributary RM 77.2 TRM 0.0 S23N04W07AAB Mainstem -upstream of Montana Creek RM 77.5 S23N04W06CAA Mainstem -Parks Highway Bri dge .,.East Shore RM 83.9 1982 S24N05W15BAD RM 83.8 1981 S24N05WI5BAD Surface water Thermograph Surface water Tbermograph Surfa,ce w,a,ter Thermo.graph 06112181-07/24/81 09/30/81-10/13/8'1 06/121'8:1-0:7/03/81 08130/81-10/13/81 06}11l81"07/14/81' 08122/82-10/2618;2 x X x X x r""'" ,~~." Appendix Table 4-C-1 (Conti nued)...... 1981 Final Draft Period of Report Vol.2 1983 Draft Basic Location Instrument Record Part I Data Report Vol.4 Mainstem -Parks Highway Surface water 06/08/82-07/09/82 X Bridge -West Shore Thermograph RM 83.9 S24N05W15BAB Mainstem -LRXl Surface water 06/08/82-06/24/82 X RM 97.0 Thermograph S26N05W23DCB Talkeetna River Surface water 06/21/81-10/04/81 X ,~Tributary Thermograph 06/08/82-06/24/82 X RM 97.2 TRM 1.5 1982 07/31/82-10/22/82 X S26N05W24BDA RM 97.0 TRM 1.0 19B1 Chu li tna Ri ve r Surface water 06/20/81-07/16/81 X Tributary Thermograph 09/09/81-09/28/81 X RM 98.6 TRM 0.5 1981 S26N05W15DAA 06/08/82-06/24/82 X TRM 0.6 1982 08/22/82-09/25/82 X S26N05W14CBC 10/09/82-10/22/82 X Whiskers Creek Slough Surface water 02/22/82-05/06/82 X p ......"...--, Side Slough Thermograph RM 101.2 S26N05W03ADB Mainstem -Talkeetna Surface water 06/20/81-07/10/81 X Fishwheel camp Thermograph 08/07/81-08/25/81 X RM 103.0 09/09/81-09/30/81 X S27NOSW26DDD 06/24/82-07/03/82 X 07/07/82-09/15/82 X 09/22/82-10/26/82 X Mainstem -LRX 18 Surface water 07/07/82-10/17/82 X RM1l3.0 Thermograph S28N04W12DAB Mainstem -Curry Surface water 07/07/82-09/30/82 X Fi shwheel camp Thermograph RM 120.7 ~S29N04Wl0CBB Mainstem -LRX 29 Surface water 07/09/82-07/27/82 X RM 126.1 Thermograph 07/29/82-10/01/82 X S30N03W19DCA-Mouth of Slough BA Surface water 08/21/82-10/25/82 X Side Slough Oatapod RM 125.4 S30N03W30BCD Slough 8A -mid slough Surface water 07/28/82-10/20/82 X (area of R&M Stage Thermograph Recorder)--Side Slough RM 126.0 S30N03W20BCA t~ Slough 8A -upper slough Surface/Intra 08/21/82-10/25/82 X Side Slough Datapod RM 126.4 S30N03W20COD 4-C-3 Appendix Table 4-C-'(Continued). ==================================================--,1981 Final Draft Report Vo1.2 Part ILocation Slough 9 -downstream of Tributary B Side Slough RM 129.0 S30N03W16ABC Slough 9 -Area of R&M Stage Recorder Side Slough RM 129.2 S30N03W16ACB Slough 9B Side Slough RM 129.0 S30N03W16ABB Mainstem -LRX 35 RM 130.8 S30N03W03DCA Mainstem -above Fourth of July Creek RM 131.3 S30N03W03DAB Slough 11 Side Slough RM 135.3 S31N02W19DDD RM 135.7 S31N02W30ADC Gold Creek Tributary RM 136.8 TRM 0.0 S31N02W20BAA Period of Record Surface water 03/28/82-05/02/82 Thermograph Intragtavel 02/09/82-05/06/82 Thermograph Surface water 07/28/82-09/13/82 Thermograph 09/20/82-10/30/82 Surface water 02127/82-05/06/82 Thertnograph Intl"agravel 02/27/82-05/06/82 Ther1llOgraph Surface water 09/02/82-09/18/82 Thermograph Surface water 06/16/81-09/04/81 Thermograph 09/07/81-09/28/81' Surface water 02/24/82-04/22/82 Thermograph S!Irf aceII ntra08121/82-1 0/25/82 Datapod Surface water 07(24/81'-08/03/81 Thertnograpl'l x x )( 1983 Draft Basic Data Report Vol.4 x X x )( ,-....- x Mainstem -above Gold Creek RM 136.8 S31N02W20BAA Slough 16B Side Slough RM 138.0 S31N02W17AAA Surface water The rll\()graph Surface/Intra Datapod 07/24/81-08/03/81 081071&'1-08117/81 ·0ll/2l/81·...09/29!81 08/21/82-10/25/82 I ndi an River Tributary RM 138.6 TRM 0.1 S31N02W09CDA RM 138.6 TRM 1.0 S31N02W09CBA Surfacewater 07/18/81-07127/81 Thermograph 06108/82-08/04/82 Surface water 08/08/82-10/22/82 /stage Datapod (Pressure Tran'sducer) Mainstem-above Indian River RM 138.7 S31N02W09DCB Surface water Thermograph 07/19l81":07129/81 08/01/81-08/0Sl81 09/25/'81""'09/29/81 4-C-4 ~ '('~, Appendix Table 4~C-1 (Conti nued). 19B1 Final Draft Period of Report Vol.2 1983 Draft Basic-Location Instrument Record Part 1 Data Report Vol.4 Slough 19 Surface water 08/27/81-09/13/81 X Upland Slough Thermograph RM 140.0 S31 Nll Wl ODBB Intragravel 02/05/82-04/13/82 j{ Thermograph Surface/Intra 08/21/82-10/25/82 X Datapod 08/21/82-09/30/82 X Surface water 02/7/82-05/06/82 X Thermograph Mainstem -LRX 53 Surface water 08/04/82-09/14/82 X RM 140.1 Thermograph S31NllWl0AAC Slough 21 Su rface/Intra 09/17/82-10/25/82 X mouth of slough Datapod RM 142.0 Side Slough F"S31N02W02AAB Slough 21 tntragravel 02/06/82-04/24/82 X mouth of slough Thermograph RM 142.0 Surface water 02/06/82-05/03/82 ~~Side Slough Thermograph S31N02W02AAA Slough 21 Surface water 03/08/82-05/03/82 X .....middle of slough Thermograph 07/28/82-10/27/82 RM 142.0 Side Slough S31N11W09AAA Slough 21 Surface/Intra 08/21/82-10/25/82 X upper slough Datapod RM 142.0 S32N02W36CCC Portage Creek Surface water 06/08/82-06/13/82 X Tributary Thermograph 06/24/82-07/02/82 X RM 148.8 TRM 0.1 07/08/82-07/31/82 X S32NOl W25CAB 08/04/82-08(31/82 X Mainstem -above Surface water 07/17/81-07/29/81 X Portage Creek Thermograph 08/01/81-09/08/Bl X RM 148.8 09/10/81-10/03/81 X S32NOl W25CDA Mainstem -Devil Canyon Surface water/08/08/82-10/10/82 X· RM 150.1 Dissolved gas S32N01E31CBD Datapod Tsusena Creek Surface water 06/19/82-10/16/82 X Tributary Thermograph X RM 181.3 TRM 0.0 S32N04E36ADB ,,'~~ 4-C-5 Appendix Table 4-C-1 (Continued). 1983 Draft Basic Data Report Vol.4 X X X Period of Record 06/20/82~08/1S/82 09/08/82-09/19/82 09/27/82~10/16/82 lnstrl,jrnent Surfi;lce water ThermogriJph Location Watana Creek Tributary RM 194.1 TRM 0.0 S32N06E25CCA ======================::::::::::=================---::;-1981 Fi nal Draft Iieport Vol.2 Part I Kosina Creek Tributary RM 206.8 TRM 0.0 S31N08E15BAB Surface water Thtil rlll9gr apt! 06/27/82-08/17/82 O~/19/82-10/16/82 X X Goose Creek Tributary RM 231.3 TRM 0.0 S30N11E32DBC Surfi;lce water Thermograph 06/27/82-10/16/82 X Oshetna Ri ver Tributary RM 233.4 TRM 0.0 S30NllE34CCD Surface water Thermograph 06/27/82-07/02/82 07/08/82-07/22/82 07/28/82-09/27/82 X X X ...... 4-C-6 ---Table 4-C-2.Thermographd$ta summary.summer surface water temperature (C). Su Station.RM 25.8.Geocode S17N07W22DCD. -MAY 1982 - ------------------------------------------~-----------------------~=-~~-~---~--TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 2S -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ------------------------------------------------~"""'_.....- 0001 -0600 ------------1.9 1.9 1.9 5.4 5.6 5.9 0601 -1200 -------------1.9 2.1 2.4 5.4 5.7 5.9 1201 -1800 -------------2.4 2.4 2.4 5.9 6.2 6.4 1801 -2400 -- - -----_._-2.4 2.4 2.4 5.9 5.9 5.9 DAILY VALUE -----------1.9 2.2 2.4 5.4 5.9 6.4 0001 -0600 ----- --------2.4 2.4 2.4 5.4 5.6 5.9 0601 -1200 -----..---------2.4 2.4 2.4 5.4 5.4 5.4 1201 -1800 --- -------2.9 2.9 2.9 5.4 5.4 5.4 1801 -2400 ---- --------2.9 2.9 2.9 4.9 5.2 5.4 DAILY VALUE -----------2.4 2.7 2.9 4.9 5.4 5.9 0001 -0600 -----------2.9 2.9 2.9 4.9 4.9 4.9 0601 -1200 ------------2.9 3.2 3.4 4.9 5.4 5.9 1201 -1800 ------------------3.4 3.4 3.4 5.9 5.9 5.9 1801 -2400 -------------3.4 3.4 3.4 5.4 5.6 5.9 DAILY VALUE --------------2.9 3.2 3.4 4.9 5.4 5.9 ~'",~,0001 -0600 ----- -------3.4 3.4 3.4 5.4 5.4 5.4 0601 -1200 -------------3.4 3.4 3.4 5.9 6.1 6.4 1201 -1800 ------------3.4 3.4 3.4 6.9 6.9 6.9 1801 -2400 -----------3.4 3.4 3.4 6.9 6.9 6.9 DAILY VALUE ----------3.4 3.4 3.4 5.4 6.3 6.9 0001 -0600 ----------- --- 2.9 3.1 3.4 6.4 6.4 6.4 0601 -1200 ------------3.4 3.7 3.9 6.4 6.4 6.4 1201 -1800 ----------------4.4 4.4 4.4 6.4 6.4 6.4 1801 -2400 -----------------4.4 4.4 4.4 5.9 6.2 6.4 DAILY VALUE -----------------2.9 3.9 4.4 5.9 6.4 6.4 0001 ~0600 -----------------3.9 3.9 3.9 5.9 5.9 5.9 0601 -1200 --------------3.9 4.2 4.4 6.4 6 ~7 6.9 1201 -1800 ------------4.9 4.9 4.9 7.4 7.7 7.9 1801 -2400 ------- ---------4.4 4.6 4.9 7.4 7.7 7.9 DAILY VALUE ---------------3.9 4.4 4.9 5.9 7.0 7.9 0001 -0600 -------------3.9 3.9 3.9 7.4 7.4 7.4 0601 -1200 ---------------4.4 4.7 4.9 7.9 8.4 8.9 1201 -1800 ------ ------5.4 5.4 5.4 9.4 9.4 9.4 1801 -2400 -----------------5.4 5.4 5.4 9.4 9.4 9.4 DAILY VALUE ------------ --- 3.9 4.9 5.4 7.4 8.6 9.4 0001 -0600 -----------------5.4 5.4 5.4 ------------0601 -1200 -----------5.9 6.2 6.9 MONTHLY VALUE 1201 -1800 --------2.9 2.9 2.9 6.4 6.7 6.9 --------------1801 -2400 ---------1.9 2.2 2.4 5.9 6.2 6.4 1.9 ---9.4 DAILY VALUE --------1.9 ----2.9 5.4 6.1 6.9 -~--------------------------------------------------------------------------- 4-C-7 - Table 4-C-2.Cont.~ ~ -JUNE 1982 -~ -----------..........------------------~--------------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------..--~-----..._------------------i 0001 -0600 8.9 8.9 8.9 7.4 7.7 7.9 ------------0601 -1200 8.9 9.2 9.4 7.4 7.7 7.9 --------1201 -1800 9.9 9.9 9.9 7.9 7.9 7.9 -------------1801 -2400 9.4 9.7 9.9 8.4 8.4 8.4 --',------------DAILY VALUE 8.9 9.4 9.9 7.4 7.9 8.4 ------------ 0001 -0600 8.9 8.9 8.9 7.9 7.9 7.9 ----------- 0601 -1200 8.9 9.1 9.4 7.9 7.9 7.9 -----------1201 -1800 9.4 9.4 9.4 7.9 7.9 7.9 ---------- 1801 -2400 7.9 8.6 8.9 .-......------------- DAILY VALUE 7.9 9.0 9.4 7.9 ---7.9 --....--...------ 0001 -0600 6.9 7.2 7.4 -----,~--------- 0601 1200 6.9 7.1 7.4 MlllliJI.-- ----------- 1201 -1800 7.4 7.7 7.9 -------------- 1801 -2400 7.9 7.9 7.9 --....-----------DAILY VALUE 6.9 7.5 7.9 ---.-----~---~ 0001 -0600 7.4 7.4 7.4 --...--------.-- 0601 -1200 7.4 7.6 7.9 ---------.---..------1201 -1800 7.9 7.9 7.9 --......-----------'--- 1801 -2400 7.9 7.9 7.9 -------------DAILY VALUE 7.4 7.7 7.9 -------- ----- 0001 -0600 7.9 7.9 7.9 .....~--------------~ 0601 -1200 7.4 7.4 7.4 - ----..----------- 1201 -1800 7.9 7.9 7.9 -----------------1801 -2400 7.9 7.9 7.9 ------ ------- DAILY VALUE 7.4 7.8 7.9 ~--------------- 0001 -0600 7.4 7.4 7.4 ---------------- 0601 -1200 7.4 7.4 7.4 ---.....-----------""""1201 -1800 7.4 7.4 7.4 ------...---------1801 -2400 6.9 7.2 7.4 ---------------_. DAILY VALUE 6.9 7.4 7.4 -------,------- ~ 0001 ..0600 6.9 6.9 6.9 -------------------- 0601 -1200 6.9 6.9 6.9 ----.-------------.. 1201 -1800 6.9 7.1 7.4 -------------------- 1801 -2400 6.9 7.2 7.4 ------------------DAILY VALUE 6.9 7.0 7.4 ----------------- 0001 -0600 6.9 6.9 6.9 ----------------- 0601 -1200 6.9 6.9 6.9 ------------MONTHLY VALUE HOI ..1800 7.4 7.7 7.9 -.----------~-...------- 1801 -2400 7.9 7.9 7.9 --------------6.9 ---9.9 DAILY VALUE 6.9 7.4 7.9 --------------, --------------_._----------~----------.---.......-------~--" 4-C-8 ,- Table 4-C-3.Thermograph data summary.summer surface water temperature (C), Yentna Fishwheel,RM 30.1.TRM 4.0.Geocode S18N07W34DBC. '""'" -JUNE 1982 - --------------------------------------------------------~---------~~-~----~---TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------~ 0001 -0600 -----7.5 7.5 7.5 7.0 7.0 7.0 11.5 11.7 12.0 0601 -1200 ------7.5 7.5 7.5 7.0 7.3 7.5 11.5 11.5 11.5 1201 -1800 -~--7.5 7.8 8.0 8.0 8.2 8.5 12.0 12.2 12.5 1801 -2400 -------8.0 8.0 8.0 8.5 8.5 8.5 12.5 12.8 13.0 DAILY VALUE -------7.5 7.7 8.0 7.0 7.7 8.5 11.5 12.0 13 .0 0001 -0600 -----8.0 8.0 8.0 8.5 8.5 8.5 12.0 12.2 12.5 0601 -1200 ---- ---7.5 7.5 7.5 8.5 8.7 9.0 U.S 11.7 12.0 1201 -1800 -----7.5 7.5 7.5 9.0 9.0 9.0 12.0 12.0 12.0 1801 -2400 ------7.0 7.2 7.5 9.0 9.0 9.0 12.0 12.3 12.5 DAILY VALUE ---------7.0 7.5 8.0 8.5 8.8 9.0 11.5 12.0 12.5 0001 -0600 --------6.5 6.8 7.0 9.0 9.0 9.0 11.5 11.8 12.0 0601 -1200 ------6.5 6.7 7.0 9.0 9.0 9.0 11.0 11.0 11.0 1201 -1800 ------7.0 7.2 7.5 9.5 9.8 10.0 11.0 11.2 11.5 ~',1801 -2400 --------7.5 7.5 7.5 10.5 10.5 10.5 11.0 11.3 11.5 DAILY VALUE ----- ---6.5 7.0 7.5 9.0 9.6 10.5 11.0 11.3 12.0 0001 -0600 ------7.0 7.2 7.5 10.5 10.5 10.5 10.0 10.5 11.0 fIIlll@;,,~0601 1200 7.0 7.0 7.0 10.5 10.5 10.5 10.0 10.0 10.0------- 1201-1800 ----7.0 7.5 8.0 10.0 10.0 10.0 10.0 10.3 10.5 1801 -2400 ------8.0 8.0 8.0 9.5 9.7 10.0 10.5 10.5 10.5 DAILY VALUE ------7.0 7.4 8.0 9.5 10.2 10.5 10.0 10.3 11.0 0001 -0600 ------7.5 7.8 8.0 9.0 9.2 9.5 9.5 9.7 10.0 0601 -1200 ------7.5 7.7 8.0 8.5 8.5 8.5 9.0 9.2 9.5 1201 -1800 ------8.0 8.0 8.0 8.5 8.5 8.5 9.5 9.8 10.0 1801 -2400 -------8.0 8.3 8.5 8.0 8.0 8.0 9.5 9.7 10.0 DAILY VALUE --------7.5 8.0 8.5 8.0 8.5 9.5 9.0 9.6 10.0 0001 -0600 ----8.0 8.0 8.0 7.5 7.8 8.0 8.5 8.8 9.0 0601 -1200 -----8.0 8.0 8.0 7.5 7.5 7.5 8.5 8.5 8.5 1201 -1800 ---------8.0 8.0 8.0 8.0 8.0 8.0 8.5 8.7 9.0 1aOl -2400 -------8.0 8.0 8.0 8.0 8.0 8.0 8.5 8.7 9.0 DAILY VALUE -------8.0 8.0 8.0 7.5 7.8 8.0 8.5 8.7 9.0 0001 -0600 -------8.0 8.0 8.0 8.0 8.0 8.0 --------- "I""0601 -1200 ---------8.0 8.0 8.0 8.0 8.0 8.0 ----------- 1201 -1800 ----------8.0 8.0 8.0 8.5 8.7 9.0 --------- 1801 -2400 -------._--8.0 8.2 8.5 9.0 9.0 9.0 ------ ---- DAILY VALUE ------- ---- 8.0 8.0 8.5 8.0 8.4 9.0 ---------- ~ 0001 -0600 --------8.0 8.2 8.5 9.0 9.0 9.0 ------------ 0601 -1200 --....------8.0 8.0 8.0 9.5 9.7 10.0 MONTHLY VALUE 1201 -1800 7.5 ---7.5 8.0 8.0 8.0 11.0 11.3 11.5 ------------ 1801 -2400 7.5 7.5 7.5 7.5 7.7 8.0 12.0 12.0 12.0 6.5 8.9 13.0 DAILY VALUE 7.5 ---7.5 7.5 8.0 8.5 9.0 10.5 12.0 -------------------------------------------------------------------------------- 4-C-9 Table 4-C-3.Cent. -AUGUST 1982 - --~~---------~-----------------------------------------------------~---------TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ...._----------------------------------------------------- 0001 -0600 8.5 9.0 9.5 9.0 9.0 9.0 8.5 8.7 9.0 8.5 8.5 8.5 0601 -1200 8.5 8.7 9.0 .9.0 9.0 9.0 8.0 8.0 8.0 8.0 8.3 8.5 1201 -1800 9.5 9.7 10.0 9.0 9.2 9.5 8.0 8.2 8.5 8.0 8.0 8.0 1801-2400 10.0 10.0 10.0 9.5 9.5 9.5 8.5 8.5 8.5 8.5 8.5 8.5 DAILY VALUE 8.5 9.3 10.0 9.0 9.2 9.5 8.0 8.3 9.0 8.0 8.3 8.5 0001 -0600 9.0 9.5 10.0 9.0 9.2 9.5 8.0 8.3 8.5 8.5 8.5 8.5 '"""0601 -1200 9.0 9.0 9.0 8.0 8.3 8.5 7.5 7.7 8.0 8.0 8.2 8.5 i 1201 -1800 9.5 9.7 10.0 8.0 8.0 8.0 7.5 7.8 8.0 8.5 8.7 9.0 1801 -2400 10.0 10.0 10.0 7.5 7.7 8.0 8.0 8.0 8.0 9.0 9.0 9.0 DAILY VALUE 9.0 9.5 10.0 7.5 8.3 9.5 7.5 8.0 8.5 8.0 8.6 9.0 0001 -0600 9.5 9.7 10.0 7.0 7.2 7.5 8.0 8.0 8.0 8.0 8.3 8.5 0601 -1200 9.0 9.0 9.0 7.0 7.0 7.0 8.0 8.0 8.0 8.0 8.0 8.0 1201 -1800 9.5 9.7 10.0 7.0 7.3 7.5 8.0 8.2 8.5 8.5 8.5 8..5 1801 -2400 10.0 10.0 10.0 7.5 7.5 7.5 8.5 8.7 9.0 8.5 8.8 9.0 DAILY VALUE 9.0 9.6 10.0 7.0 7.2 7.5 8.0 8.2 9.0 8.0 8.4 9.0 0001 -0600 9.5 9.7 10.0 7.5 7.5 7.5 9.0 9.0 9.0 8.5 8.8 9.0 0601 -1200 9.0 9.0 9.0 7.5 7.7 8.0 8.5 8.5 8.5 8.5 8.5 8.5 1201 -1800 9.0 9.3 9.5 8.5 9.0 9.5 9.0 9.0 9.0 8.5 8.5 8.5 1801 -2400 10.0 10.0 10.0 9.0 9.2 9.5 9.0 9.0 9.0 8.5 8.5 8.5 DAILY VALUE 9.0 9.5 10.0 7.5 8.3 9.5 8.5 8.9 9.0 8.5 8.6 9.0 0001 -0600 9.5 9.8 10.0 9.0 9.3 9.5 9.0 9.0 9.0 8.0 8.3 8.5 0601 -1200 9.0 9.2 9.5 9.0 9.0 9.0 8.5 8.5 8.5 7.5 7.7 8.0 1201 -1800 9.5 9.5 9.5 9.5 9.7 10.0 8.5 8.5 8.5 7.5 7.5 7.5 1801 -2400 10.0 10.0 10.0 10.0 10.2 10.5 8.5 8.5 8.5 7.5 7.5 7.5 DAILY VALUE 9.0 9.6 10.0 9.0 9.5 10.5 8.5 8.6 9.0 7.5 7.7 8.5 0001 -0600 9.5 9.8 10.0 10.0 10.3 10.5 8.5 8.5 8.5 7.5 7.5 7.5 0601 -1200 9.5 9.5 9.5 10.0 10.0 10.0 8.5 8.5 8.5 7.5 7.5 7.5 1201 -1800 9.5 9.8 10.5 10.0 10.0 10.0 8.5 8.5 8.5 7.5 7.5 7.5 1801 -2400 10.5 10.7 11.0 10.0 10.0 10.0 8.5 8.5 8.5 7.5 7.5 7.5 DAILY VALUE 9.5 10.0 11.0 10.0 10.1 10.5 8.5 8.5 8.5 7.5 7.5 7.5 0001 -0600 10.5 10.8 11.0 9.5 9.8 10.0 8.5 8.5 8.5 7.5 7.5 7.5 0601 -1200 9.5 9.8 10.0 8.5 8.8 9.0 8.5 8.5 8.5 7.5 7.5 7.5 1201 -1800 9.5 9.5 9.5 8.0 8.3 8.5 8.5 8.5 8.5 7.5 7.5 7.5 1801 -2400 9.5 9.5 9.5 8.0 8.0 8.0 8.5 8.5 8.5 7.5 7.5 7.5 DAILY VALUE 9.5 9.9 11.0 8.0 8.7 10.0 8.5 8.5 8.5 7.5 7.5 7.5 0001 -0600 9.0 9.3 9.5 8.0 8.0 8.0 8.5 8.5 8.5 -------------- 0601 -1200 8.5 8.5 8.5 8.0 8.0 8.0 8.5 8.5 8.5 MONTHLY VALUE 1201 -1800 8.5 8.5 8.5 8.0 8.3 8.5 8.5 8.5 8.5 -----------'---r-1801 -2400 8.5 8.8 9.0 8.5 8.8 9.0 8.5 8.5 8.5 7.0 8.7 11.0 i DAILY VALUE 8.5 8.8 9.5 8.0 8.3 9.0 8.5 8.5 8.5,~- .....-------------------------------------------------------------------------------- ! 4-C-ll Table 4-C-3.Cont. -OCTOBER 1982 ~ ------------------------------------------------------------------~~~==----~----TIME PERIOD DAYS 1 - 8 MI~MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 IF'1201 1800, 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 "'01".........0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 -0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE r 0001 0600 l 0601 1200 1201 1800 F"'"1801 2400 I DAILY VALUE .5 .5 .5 .5 .7 1.0 1.0 1.0 1.0 1.0 1.0 1.0 .5 .8 1.0 1.0 1.0 1.0 1.0 1.0 1.0 -- 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 .5 .7 1.0 0.0 .2 .5 .5 .5 0.0 1.0 4.0 4.0 3.5 3.7 4.0 3.5 4.0 3.0 3.0 3.0 2.5 2.5 2.5 2.5 2.5 2.5 1.5 1.8 2.0 1.5 2.5 3.0 1.0 1.3 1.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.5 1.0 1.0 1.0 .5 .5 .5 .5 .5 .5 .5 .5 .5 .5 .6 1.0 .5 .5 .5 -------------- .5 .5 .5 MONTHLY VALUE .5 .5 .5 -------------- .5 .5 .5 0.0 ----4.0 .5 .5 .5 4-C-13 Table 4-C-4.Thermograph data summary,summer surface water emperature (C), Susitna River Upstream of Yentna River,RM 29.,Geocode S17N06W07CAD. -JUNE 1982- ~---------------------------------------~~~-----~~~~....'-.--~-~'~....-,----~-~-~~~_. TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEt\NMAx DAYS 17 '"'24 MIN MEAN MAx DAYS 25 ...31 MIN MEAN MAx .-';'.-'.'',',"'.'-,',.'.:""""""""'-,'-------------------------~------------------------~--------~---------------- 0001 -0600 ---------------'7.5 7.7 8.0 ------- ----12.0 12 ..2 12.5 0601 -1200 --------------7.5 7.5 7.5 ------12.0 12.0 12.0 1201 -1800 ------------8.0 8.0 8.0 ----~---12.5 13.0 13.5 1801 -2400 -----------8.5 8.5 8.5 ....'--'.--------13.5 13 .5 13,.5 DAlLY VALUE ---------7.5 709 8.5 -----~-,;,;;.12.0 12.7 13.5 0001 -0600 -----------8.0 8.0 8.0 -----------12.5 1207 13.0 0601 -120'0 ------------------~.O 8.0 Eh'O --------'-"-'12.5 12.5 12.5 1201 -1800 --------8.0 8.,6 8.0 10.0 10.0 10.0 13.0 13.2 13.5 1801 -2400 --- --- _--ii.8~6 8.0 8.0 9.5 9.8 Ib~6 13.0 13.3 13 ..5 DAlLY VALUE ------------8.0 8.0 8.0 9.5 ---10.0 12.5 12.9 13.5 0001 -0600 --------7.5 7.5 7.5 9.5 9.5 9.5 12.0 12.5 13.0 0601 -1200 -----~-7.5 7.5 7.5 9.0 9.3 9.5 12.0 12.0 12.0 U01 -1800 -------8.9 S.o 8.0 10.0 10.2 10.S 12.0 12.0 12.0 1801 -2400 -----8.0 8.6 S.O 10.5 1(>05 10.5 12.0 12.0 1:2.6 DAlLY VALUE --------7.5 7.8 8.0 9.0 9.9 10.5 12.0 12.1 13.0 0001 -0600 --'---7.5 7.7 8.0 10.0 10.0 10.0 Il.O 11.3 11.5 0601 -1200 -_.....----7.5 7.5 7.5 9.5 9.8 10.0 lLO 11.0 11.0 1201 -1800 ------------8.0 8.3 8.5 9~5 9.5 9.S 11.0 11.3 1L5 1801 -2400 ----------7.5 8:2 8 ..5 9.0 9.3 9 ..5 11 .5 11.8 12.0 DAlLY VALUE --------------7.5 7.9 8.S 9.0 9.1 10ol)H.O 11.4 12 ..0 0001 -0600 --------7.5 7.S 7.5 8.0 8.5 9.0 11.0.11.2 110S 0601 -1200 --- ---------7.5 7.5 7 ..5 8.0 8.0 8.0 10.5 10.7 11.0 1201 -1800 -----7.5 8.0 8~5 8.0 8.3 8.5 11.0 11.3 11.5 1801 -2400 ------~8.5 8.5 8.5 8.5 8.5 8.5 11.5 11.5 11.5 DAlLY VALUE ------7.5 7.9 8.5 8.0 8.3 9.0 10.5 11.2 11.5 0001 -0600 ----- --- 8.0 8.3 8.5 8.5 8.5 8 ..5 10.5 11.0 11.5 0601 -1200 ---------8.0 8.2 8.5 8.5 8.5 8.5 10.5 10.5 10.5 1201 -1800 -------------------8.S 9.0 9.5 10.5 io.s 11.5 1801 -2400 -----------9.5 9.5 9.5 10.5 11.0 11.5 DAlLY VALUE --------8.0 ...........8.5 8.5 8.9 9.5 10.5 10.8 lL5 0001 -0600 -------------------------9.5 9.5 9.5 ------~..~ 0601 -1200 ---------------..9.5 9.7 10.0 ----------- 1201 -1800 ------------------10.5 10.8 1100 -------- 1801 -2400 -------------11.5 I1.S 11.5 ---------- DAILY VALUE ----------------9.5 10.4 11.5 ------....---~..- 0001 -0600 ---------------10.5 10.8 11.0 ----------.01!-~0601 -1200 --------------------------10.5 10.7 11.0 MONTHLY VALUE 1201 -1800 8.0 ---8.0 ------11.5 12 ..0 12.5 -------------- 1801 -2400 8.0 8.0 8.0 -----12 ..5 12.8 13.0 7.5 ---13.5 DAILY VALUE 8.0 --8.0 -------10.5 11.6 13 .0 -',--<.''.'',-.',- -.'',,-.'.'.',".'.'~.'.-,------------------------~-----~------------------------------------------------ 4-C-14 Table 4-C-4.Cont. -JULY 1982 - ---~-----------------------------------------------------------_.---~~--------TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX.MIN MEAN MAX.MIN MEAN MAX ---------------------------------------------------------------------------- ~~0001 -0600 10.0 10.2 10.5 1l.5 11.8 12.0 9.5 9.5 9.5 9.5 9.5 9.5 0601 -1200 10.0 10.0 10.0 11.5 11.812.0 9.5 9.7 10.0 9.0 9.2 9.5 1201 -1800 10.5 10.5 10.5 12.0 12.0 12.0 10.5 10.5 10.5 9.5 9.7 10.0 1801 -2400 10.0 10.3 10.5 12.0 12.0 12.0 10.5 10.5 10.5 9.5 9.8 10.0 DAILY VALUE 10.0 10.2 10.5 11.5 11.9 12.0 9.5 10.0 10.5 9.0-9.5 10.0 0001 -0600 9.5 9.8 10.0 11.5 11.5 11.5 10.0 10.2 10.5 9.0 9.3 9.5 0601 -1200 9.5 9.7 10.0 12.0 12.0 12.0 10.0 10.3 10.5 9.0 9.2 9.5 1201 -1800 10.0 10.3 10.5 12.0 12.0 12.0 10.5 10.8 11.0 9.5 9.8 10.0 1801 -2400 10.5 10.5 10.5 11.5 11.8 12.0 11.0 11.2 11.5 9.5 9.8 10.0 DAILY VALUE 9.5 10.1 10.5 11.5 11.8 12.0 10.0 10.6 11.5 9.0 9.5 10.0 0001 -0600 9.5 10.0 10.5 10.5 11.0 11.5 10.0 10.3 10.5 9.5 9.5 9.5 0601 -1200 9.5 10.0 10.5 10.5 10.5 10.5 10.5 10.5 10.5 9.5 9.5 9.5 1201 -1800 10.5 10.8 11.0 11.0 11.3 11.5 11.0 11.3 11.5 10.0 10.210.5 1801 -2400 11.0 11.3 11.5 11.5 11.5 11.5 11.5 11.8 12.0 10 •.5 10•5 10.5 DAILY VALUE 9.5 10.5 1l.5 10.5 11.1 11.5 10.0 11.0 12.0 9.5 9.9 10.5 0001 -0600 10.5 10.7 11.0 10.5 10.8 11.0 11.5 11.5 11.5 10.0 10.0 10.0 0601 -1200 10.5 10.7 11.0 10.5 10.5 10.5 11.5 12.0 12.5 10.0 10.2 10.5 1201 -1800 11.0 11.3 11.5 10.5 10.5 10.5 13.0 13.3 13.5 10.5 10.5 10.5 1801 -2400 11.0 11.3 11.5 10.5 10.5 10.5 13.5 13.5 13.5 10.5 10.5 10.5 DAILY VALUE 10.5 11.0 11.5 10.5 10.6 11.0 11.5 12.6 13.5 10.0 10.3 10.5 0001 -0600 10.5 10.7 11.0 10.5 10.5 10.5 12.5 12.8 13.0 10.5 10.5 10.5 0601 -1200 11.0 11.2 11.5 10.5 10.5 10.5 12.5 12.5 12.5 10.5 10.5 10.5 1201 -1800 12.0 12.3 12.5 11.0 11.2 11.5 12.5 12.8 13.0 10.5 10.5 10.5 1801 -2400 12.0 12.3 12.5 11.0 11.2 11.5 12.0 12.3 12.5 10.5 10.5 10.5 DAILY VALUE 10.5 11.6 12.5 10.5 10.8 11.5 12.0 12.6 13.0 10.5 10.5 10.5 0001 -0600 11.5 11.7 12.0 10.5 10.7 11.0 11.0 11.3 11.5 10.0 10.3 10.5 0601 -1200 11.0 11.3 11.5 10.5 10.7 11.0 11.0 11.0 11.0 10.0 10.2 10.5 1201 -1800 11.5 11.812.0 11.0 11.3 11.5 11.0 11.0 11.0 10.5 10.5 10.5 1801 -2400 12.0 12.0 12.0 11.5 11.5 11.5 11.0 11.0 11.0 10.5 10.5 10.5 DAILY VALUE 11.0 11.7 12.0 10.5 11.0 11.5 11.0 11.1 11.5 10.0 10.4 10.5 0001 -0600 11.0 11.3 11.5 11.0 11.0 11.0 10.5 10.5 10.5 10.0 10.2 10.5 0601 -1200 11.0 11.3 11.5 10.5 10.8 11.0 10.0 10.0 10.0 10.0 10.0 10.0 1201 -1800 12.0 12.5 13.0 1l.0 11.0 11.0 10.0 10.0 10.0 10.5 10.5 10.5 1801 -2400 12.5 12.8 13.0 10.5 10.5 10.5 9.5 9.7 10.0 10.5 10.5 10.5 DAIL'Y VALUE 11.0 12.0 13.0 10.5 10.8 11.0 9.5 10.0 10.5 10.0 10.3 10.5 !""" 0001 -0600 12.0 12.3 12.5 9.5 9.8 10.0 9.5 9.5 9.5 ------------- 0601 -1200 12.0 12.0 12.0 9.5 9.8 10.0 9.5 9.5 9.5 MONTHLY VALUE 1201 -1800 12.5 12.5 12 .5 10.0 10.0 10.0 9.5 9.5 9.5 ----------- 1801 -2400 12.0 12.3 12 .5 9.5 9.8 10.0 9.5 9.5 9.5 9.0 10.8 13.5 DAILY'VALUE 12.0 12.3 12.5 9.5 9.9 10.0 9.5 9.5 9.5 -------------------------------------------------------------------------------,..,. 4-C-15 - Table 4-C-4.Cont. ...AUGUST 1982 - ----------------------------_._~-~-._-------------------------------~------------ TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 ...16 MINMEAN MAX DAYS 17 -24 MINMEAN MAX. DAYS 25 ...31 MIN MEAN MAX -----------------~-----------~-----------------~-----------------.------------~~ 0001 -0600 10.0 10.2 10.5 10.0 10.2 10.5 10.0 10.2 10.5 10.5 10.5 10.5 0601 -1200 10.0 10.3 10.5 10.0 10.0 10.0 9.5 9.5 9.5 10.0 10.0 10.0 1201 -1800 11.0 11.3 11.5 19.5 10.7 11.0 10.0 10.3 10.5 10.0 10.3 10.5 1801 -2400 11.0 11.3 11.5 11.0 11.0 11.0 10.5 10.5 10.5 10.5 10.5 10.5 DAILY VALUE 10.0 10.8 11.5 10.0 10.5 11.0 9.5 10.1 10.5 10.0 10.3 10.5 0001 -0600 10.5 10.7 11.0 10.5 10.5 10.5 9.5 9.8 10.0 10.0 10.3 10.5 0601 -1200 10.5 10.7 11.0 9.5 9.8 10.0 9.5 9.5 9.5 10.0 10.0 10.0 1201 -1800 11.5 1107 12.0 9.5 9.5 9 •.9 9.$9.8 10.0 10.5 10.7 11.0 1801 -2400 11.5 11.1 12.0 9.5 9.5 9.5 10.0 10.3 10.5 11.0 11.0 11.0 ~ DAILY VALUE 10.5 11.2 12.0 9.5 9.8 10.5 9.5 9 ..9 10.5 10.0 10.S 11.0 0001 -0600 10.5 10.8 11.0 9.0 9.2 9.5 9.5 9.7 10.0 10.0 10.3 10.5 0601 -1200 10.5 11.0 11.5 8.5 8.7 9.0 9.0 9.0 9.0 10.0 10.2 10.5 ~ 1201 -1800 11.5 11.8 12.0 9.0 9.3 9.5 9.5 9.8 10.0 10.5.10.7 11.0 1801 -2400 11.5 11.8 12.0 9.5 9.7 10.0 10.5 10.5 10.5 10.5 10.8 11.0 DAILY VALUE 10.5 11.4 12.0 8.5 9.2 10.0 9.0 9.7 10.5 10.0 10.5 11.0 """"'1 0001 -0600 11.0 11.2 11.5 9.5 9.5 9.5 9.5 9.8 10.0 10.0 10.3 10.5 0601 -1200 11.0 11.2 11.5 9.5 9.5 9.5 9.5 9.5 9.5 9.5 9.8 10.Q 1201 -1800 11.5 11.8 12.0 10.5 10.8 1100 10.0 10.5 11.0 10.5 10.5 10.5 ~-~1801 -2400 12.0 12.0 12.0 11.5 11.5 11.5 11.0 H.O 11.0 10.5 10.5 10.5 DAILY VALUE 11.0 11.5 12.0 9.5 10.3 11.5 9.5 10.2 11.0 9.5 10.3 10.5 0001 -0600 11.5 11.5 11.5 10.5 11.0 11.5 10.0 10.3 10.5 9.5 10.0 10.5 0601 -1200 11.5 11.7 12.0 10.5 1D.S 10.5 10.0 10.2 10.5 9.5 9.5 9.5 1201 -1800 12.0 12~3 12.5 11.0 11.3 11.5 10.5 10.8 11.0 9.5 9.5 9.5 1801 -2400 12.0 12.3 12.5 12.0 12.0 12.0 11.0 II :0 11.0 9.5 9.5 9.5 DAILY VALUE 11.5 12.0 12.5 10.5 11.2 12.0 10.0 10.6 11.0 9.5 9.6 10.5 ~ 0001 -0600 11.5 11.7 12.0 11.5 11.7 12.0 10.0 10.5 11.0 9.0 9.3 9.5 0601 -1200 11.5 11.7 12.0 11.5 11.5 11.5 10.0 10.2 10.S 9.0 9.0 9.0 1201 -1800 12.5 12.7 13 .0 11.5 11.8 12.0 10.5 10.8 11.0 9.0 9.0 9.0 1801 -2400 13 .0 13 .0 13 .0 12.0 12.0 12.0 11.0 11.0 11:0 9.0 9.0 9.0 DAlLY VALUE 11.5 12.2 13 .0 11.5 11.7 12.0 10.0 10.6 11.0 9.0 9.1 9.5 -0001 -0600 12.0 12.2 12.5 U.5 11.7 12.0 10.5 10.8 11.0 8.5 8.5 8.5 0601 -1200 11.5 11.5 11.5 10.5 10.8 11.0 10.5 10.5 10.5 8.5 8.5 8.5 1201 -1800 11.5 11.5 11.5 10.5 10.5 10.5 10.5 10.7 11.0 8.5 8.5 8.5 1801 -2400 11.5 11.5 11.5 10.0 10.0 10.0 11.0 11.0 11.0 9.0 9.0 9.0 DAILY VALUE 11.5 11.7 12.5 10.0 10.7 12.0 10.5 10.7 11.0 8.5 8.6 9.0 0001 -0600 10.5 10.7 11.0 9.5 9.5 9.5 10.5 10.7 11.0 --------------- 060\-1200 10.0 10.0 10.0 9.5 9.5 9.5 10.5 10.5 10.5 MONTHLY VALUE 1201 -1800 10.0 10.2 10.5 10.0 10.3 10,.5 10.5 10.8 11.0 ..........~-.....------ 1801 -2400 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.8 11.0 8.5 10.5 13.0 DAILY VALUE 10.0 10.3 11.0 9.5 10.0 10.5 10.5 10.7 11.0 - ------~-----------------~---------------------~-------------.-.----------~------ 4-C-16 Table 4-C-4.Cont. Table 4-C-4.Cont.IOO'\l ~' OCTOBER 1982 ~-- -------------~----~---------------------~---------------~-~~--~--~~~~---------TIME DAYS 1 -8 DAYS 9 - 16 DAYS 17 ;,;.24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MiN MEAN MAX ~..,-.",-,"-,"-",'.,,.'".,"--------------------..-------------------~-------- 0001 -0600 4.5 4.8 5.0 .5 .8 1.0 0.0 O~O 0.0 -------- 0601 -1200 4.5 4.5 4.5 1.0 1.0 1.0 0.0 0.0 O~O ---------1201 -1800 4.5 4.8 5.0 1.0 1.3 1.5 0.0 0.0 0.0 -----1801 -2400 5.0 5.0 5.0 1.5 1.5-1.5 0.0 0.0 0.0 -------- DAILY VALUE 4.5 4.8 5.0 .5 1.2 1.5 0.0 0.0 o.d -------..... 0001 -0600 4.5 4.8 5.0 1.5 1.5 1.5 -------------- 0601 -1200 4.5 4.5 4.5 1.5 1.5 1.5 --------------- 1201 -1800 4.5 4.5 4.5 1.5 1.5 1.5 ----------------- 1801 -2400 4.5 4.5 4.5 1.5 1.5 1.5 ----------------- DAILY VALUE 4.5 4.6 5.0 1.5 1.5 1.5 ---------------------- 0001 -0600 4.5 4.5 4.5 1.5 1.5 1.5 --------------- 0601 -1200 4.5 4.5 4.5 1.5 1.5 1.5 -----------------1201 -1800 4.5 4.5 4.5 1.0 1.0 1.0 ---------------- 1801 -2400 4.0 4.2 4.5 1.0 1.0 1.0 ----------------- DAILY VALUE 4.0 4.4 4.5 1.0 1.2 1.5 ----------------.... 0001 -0600 -------1.0 1.0 1.0 ------------------ 0601 -1200 ------1.0 1.0 LO ..,----------------- 1201 -1800 4.5 4.5 4.5 1.0 1.3 1.5 -------------------,-- 1801 -2400 4.0 4.2 4.5 1.0 1.0 1.0 ------------------- DAILY VALUE 4.0 --4.5 1.0 1.1 1.5 ----------------- 0001 0600 3.0 3.3 3.5 1.0 1.0 1.0 ~------ - --- 0601 -1200 2.5 2•.?2.5 1.0 1.0 1.0 --------------- 1201 -1800 2.5 2.8 3.0 1.0 1.0 1.0 ---------------- 1801 -2400 2.5 2.5 2.5 1.0 1.0 1.0 -------------------~ DAILY VALUE 2.5 2.8 3.5 1.0 1.0 1 .0 --------------- 0001 -0600 2.0 2.3 2.5 1.0 1.0 1.0 ---------------- 0601 -1200 1.5 1.8 2.0 .5 .5 .5 ------------------- 1201 -1800 2.0 2.0 2.0 0.0 .2 .5 ------------------- 1801 -2400 2.0 2.0 2.0 0.0 0.0 0.0 ------------------ DAILY VALUE 1.5 2.0 2.5 0.0 .4 1.0 -------------------- 0001 -0600 1.5 1.8 2.0 0.0 0.0 0.0 ---------------- 0601 -1200 1.0 1.3 1.5 0.0 0.0 0.0 ._------------------- 1201 -1800 1.0 1.3 1.5 0.0 .2 .5 ------------------- 1801 -2400 1.5 1.5 1.5 0.0 0.0 0.0 -----------------..- DAILY VALUE 1.0 1.5 2.0 0.0 .0 .5 ------------------ 0001 -0600 1.5 1.5 1.5 0.0 0.0 0.0 -------------------------~ 0601 -1200 1.0 1.2 1.5 ---------- --- ------MONTHLY VALUE 1201 -1800 LO 1.3 L5 0.0 0.0 0.0 --------.'.....-..-...~-------1801 -2400 .5 .8 LO o~o 0.0 0.0 -----0.0 ---5.() DAILY VALUE .5 1.2 1.5 0.0 0.0 0.0 -------- ----- ,.."","......-...-------------------------------------------------------------------------------'-',- ~, 4-C-18 Table 4-C-5.Thermograph data summary,summer surface water temperature (C), Parks Highway Bridge West,RM 83.9,Geocode S24N05W15BAB. -JUNE 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX r I 0001 -0600 ----------- 0601 -1200 ------- --- 1201 -1800 ----------- 1801 -2400 ---------- DAILY VALUE ---------- 0001 -0600 ---------- 0601 -1200 ----------- 1201 -1800 -------- 1801 -2400 -------- DAILY VALUE ----------- 0001 -0600 ------------ 0601 -1200 ---- -------- 1201 -1800 ------- --- 1801 -2400 ---------- DAILY VALUE ----------- 8.1 8.1 8.1 8.1 8.1 8.1 8.1 8.4 8.6 8.1 8.1 8.1 8.1 8.2 8.6 7.6 7.6 7.6 7.6 7.6 7.6 7.67.67.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.1 7.1 7.1 7.1 7.4 8.1 8.6 8.9 9.1 9.1 9.1 9.1 7.1 8.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.6 9.6 9.6 9.1 9.1 9.1 9.1 9.2 9.6 8.6 8.8 9.1 8.6 9.1 9.6 10.1 10.4 10.6 10.6 10.6 10.6 8.6 9.7 10.6 11.1 11.3 11.6 10.6 10.9 11.1 11.6 11.9 12.1 12.1 12.1 12.1 10.6 11.6 12.1 11.1 11.4 11.6 10.6 10.8 11.1 11.6 11.6 11.6 11.1 11.4 11.6 10.6 11.3 11.6 10.1 10.6 11.1 10.1 10.3 10.6 10.1 10.3 10.6 10.1 10.1 10.1 10.1 10.3 11.1 0001 -0600 ---- -------- 0601 -1200 ---- ------- 1201 -1800 ------------ 1801 -2400 ------------ DAILY VALUE ------------ 0001 -0600 ------------ 0601 -1200 ------------ 1201 -1800 ---- -------- 1801 -2400 ---------- DAILY VALUE ---------- 7.6 7.6 7.6 7.6 7.8 8.1 8.1 8.4 8.6 8.1 8.3 8.6 7.6 8.0 8.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 9.1 9.4 9.6 8.6 8.9 9.1 9.1 9.4 9.6 9.6 9.8 10.1 8.6 9.4 10.1 9.1 9.4 9.6 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.1 9.2 9.6 9.6 9.9 10.1 9.6 9.6 9.6 10.1 10.1 10.1 10.1 10.1 10.1 9.6 9.9 10.1 9.6 9.9 10.1 9.1 9.4 9.6 8.6 8.8 9.1 7.6 7.9 8.1 7.6 9.0 10.1 7.1 7.4 7.6 7.1 7.6 8.1 8.6 8.6 8.6 8.6 8.6 8.6 7.1 8.1 8.6 8.6 8.6 8.6 8.6 8.8 9.1' 9.6 9.6 9.6 9.6 9.6 9.6 8.6 9.1 9.6 9.6 9.6 9.6 9.1 9.4 9.6 10.1 10.4 10.6 10.6 10.6 10.6 9.1 10.0 10.6 8.1 8.6 9.6 9.6 9.6 9.6 9.1 8.6 8.1 9.6 8.1 8.3 9.6 9.6 8.9 9.4 8.8 8.6 7.9 8.7 8.1 8.1 9.6 9.6 8.1 9.1 8.6 8.6 7.6 7.6 .......-.----'--- 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUEf- I i r I I i I r 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 8.1 8.1 8.1 8.1 8.1 8.1 8.1 ---.8.1 7.1 6.6 7.1 7.1 6.6 7.3 6.9 7.1 7.1 7.1 7.6 7.1 7.1 7.1 7.6 10.1 10.3 10.6 10.1 10.3 10.6 11.1 11.4 11.6 11.6 11.6 11.6 10.1 10.9 11.6 MONTHLY VALUE 6.6 9.1 12.1 ~, 4-C-19 4-C,-20 ~, r - ..., Table 4-C-6.Thermograph data summary,summer surface water temperature (C), Parks Highway Bridge East,RM 83.9.Geocode S24N05W15BAD. -AUGUST 1982 ~ -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 ------------------------9.5 9.7 10.0 0601 -1200 ------------------------9.5 9.5 9.5 1201 -1800 ----------------------9.5 9.8 10.0 1801 -2400 ------------------------9.5 9.7 10.0 DAILY VALUE -----------------------9.5 9.7 10.0 0001 -0600 --------------------------9.5 9.5 9.5 0601 -1200 ------------------------9.0 9.2 9.5 1201 -1800 -----------------------9.5 9.8 10.0 1801 -2400 - - -------------------10.0 10.0 10.0 DAILY VALUE --------------------------9.0 9.6 10.0 0001 -0600 --'---.----- ---------eoI>___ 9.0 9.3 9.5 0601 -1200 -------------------9.0 9.0 9.0 1201 -1800 ---------------------9.5 9.5 9.5 1801 -2400 ---------------------9.5 9.5 9.S DAILY VALUE ---------------------9.0 9.3 9.5 0001 -0600 --------------------------9.0 9.0 9.0 0601 -1200 --------------------------8.5 8.5 8.5 1201 -1800 ----------------------------8.5 8~8 9.0 1801 -2400 ------------ --------------9.0 9.0 9.0 DAILY VALUE ----------------------------8.5 8.8 9.0 0001 -0600 ---------------------------8.5 8.5 8.5 0601 -1200 ----------------------8.5 8.5 8.5 1201 -1800 ------------------- --- 8.5 8.5 8.5 1801 -2400 ------------------------8.5 8.5 8.5 DAILY VALUE ------------------------8.5 8.5 8.5 0001 -0600 ------------------------8.5 8.5 8.5 0601 -1200 --------------------------8.0 8.0 8.0 1201 -1800 ---------------------------8.0 8.0 8.0 1801 -2400 ----------------10.0 10.0 10.0 8.0 8.0 8.0 DAILY VALUE -------------------10.0 10.0 8.0 8.1 8.5 0001 -0600 ----------------10.0 10.0 10.0 8.0 8.0 8.0 0601 -1200 --------------10.0 10.0 10.0 8.0 8.0 8.0 1201 -1800 --------------------10.5 10.5 10.5 8.0 8.0 8.0 1801 -2400 ---------- ----------10.0 10.3 10.5 8.0 8.0 8.0 DAILY VALUE -------------------10.0 10.2 10.5 8.0 8.0 8.0 0001 -0600 ------------------9.5 9.8 10.0 ------------- 0601 -1200 ---------------------9.5 9.5 9.5 MONTHLY VALUE 1201 -1800 --- --- -------------9.5 9.8 10.0 ------------- 1801 -2400 --- --- --------------10.0 10.0 10.0 8.0 ----10.5 DAILY VALUE ----------------------9.5 9.8 10.0 4-C-21 Table 4-C-6.Cont.- ,JfJfI:- -SEPTEMBER 1982 - --------------~--------~-------------------------------~~----------~----------TIME DAYS 1 - 8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX.MIN MEAN MAX.~ ---------------------------------------------------------~--------------------- 0001 -0600 8.0 8.0 8.0 7.5 7.5 7.5 6.5 6.5 6.5 4.1 4.3 4.6 0601 -1200 8.0 8.0 8.0 7.5 7.5 7.5 6.5 6.5 6.5 4.1 4.1 4.1 ~ 1201 -1800 8.5 8.7 9.0 7.5 7.7 8.0 6.0 6.0 6.0 4.1 4.3 4.6 1801 -2400 8.5 8.5 8.5 7.5 7.7 8.0 6.0 6.0 6.0 4.6 4.6 4.6 DAILY VALUE 8.0 8.3 9.0 7.5 7.6 8.0 6.0 6.2 6.5 4.1 4.3 4.6 ..... 0001 -0600 8.0 8.2 8.5 7.5 7.5 7.5 6.0 6.0,6.0 4.6 4.6 4.6 0601 -1200 8.0 8.0 8.0 7.5 7.5 7.5 6.0 6.0 6.0 4.6 4.6 4.6 1201 ...1800 8.5 8.5 8.5 7.5 7.5 7.5 6.0 6.0 6.0 4.6 4.6 4.6 1801 -2400 8.5 8.5 8.5 7.5 7.5 7.5 6.0 6.0 6.0 4.6 4.6 4.6 DAILY VALUE 8.0 8.3 8.5 7.5 7.5 7.5 6.0 6.0 6.0 4.6 4.6 4.6 0001 -0600 8.0 8.0 8.0 ,7.0 7.3 7.5 6.0 6.0 6.0 4.6 4.6 4.6 0601 1200 8.0 8.0 8.0 7.0 7.0 7.0 6.0 6.0 6.0 4.6 4.8 5.1 -- 1201 -1800 8.0 8.0 8.0 7.0 7.0 7.0 6.0,6.0 6.0 5.1 5.4 5.6 1801 -2400 8.0 8.0 8.0 6.5 6.8 7.0 6.0 6.0 6.0 4.6 5.1 5.6 DAILY VALUE 8.0 8.0 8.0 6.5 7.0 7.5 6.0 6.0 6.a 4.6 5.0 5.6 """1 I 0001 -0600 7.5 7.7 8.0 5.5 5.,8 6.0 6.0,6.0 6.0 4.6 4.6 4.6 ! 0601 -1200 7.5 7.5 7.5 5.5 5.5 5.5 6.0 6.2 6.6 4.1 4.1 4.1 1201 -1800 8.0 8.2 8.5 5.5 5.7 6.0 6.1 6.1 6.1 4.1 4.1 4.1 ~,- 1801 -2400 8.0 8.0 8.0 6.0 6.0 6.0 6.l 6.1 6.1;4.1 4.1 4.1 DAILY VALUE 7.5 7.8 8.5 5.5 5.7 6.0 6.0 6.1 6.6 4.1 4.2 4.6 0001 -0600 7.5 7.5 7.5 6.0 6.0 6.0 6.1 6.1 6.1 4.1 4.1 4.1 0601 -1200 7.5 7.5 7.5 5.5 5.7 6.0 6.1 6.1 6.1 4.1 4.1 4.1 1201 -1800 7.5 7.5 7.5 6.0 6.0 6.0 6.1 6.1 6.1 4.1 4.4 4.6 1801 -2400 7.5 7.5 7.5 6.0 6.0 6.0 6.1 6•.1 6.1 4.6 4.6 4.6 -DAILY VALUE 7.5 7.5 1'.5 5.5 5.9 6.0 6.1 6.1 6.1 4.1 4.3 4.6 0001 -0600 7.5 7.5 7.5 6.0 6.0 6.0 5.6 5.8 6.1 4.6 4.6 4.6, 0601 -1200 7.0 7.0 7.0 6.0 6.0 6.0 5.6 5.6 5.6 4.6 4.6 4.6 -1201 -1800 7.5 7.5 7.5 6.5 6.5 6.5 6.1 6.1 6.1 4.6 4.6 4.6 1801 -2400 7.5 7.5 7.5 6.5 6.5 60S 5.6 5.8 6.1 4.6 4.6 4.6 DAILY VALUE 7.0 7.4 7.5 6.0 6.2 6.5 5.6 5.8 6.1 4.6 4.6 4.6 ~ 0001 -0600 7.5 7.5 7.5 6.5 6.5 6.5 5.1 5.3 5.6 --------- 0601 -1200 7.5 7.5 7.5 6.5 6.5 6.5 4.6 4.6 4.6 ------_.--- 1201 -1800 8.0 8.3 8.5 6.5 6.5 6.5 5.1 5.4 5.6 _.------ 1801 2400 8.0 8.3 8.5 6.5 6.8 7.0 5.1 5.3 5.6 ~--------- DAILY VALUE 7.5 7.9 8.5 6.5 6.6 7.0 4.6 5.1 5.6 --------- 0001 -0600 8.0 8.0 8.0 7.0 7.0 7.0 4.6 4.6 4.6 ------------~ 0601 -1200 8.0 8.0 8.0 7.0 7.0 7.0 4.1 4.1 4.1 MONTHLY VALUE 1201 -1800 8.0 8.0 8.0 7.0 7.0 7.0 4.1 4.4 4.6 ------------- 1801 -2400 7.5 7.8 8.0 6.5 6.7 7.0 4.6 4.6 4.6 4.1 6.3 9.0 DAILY VALUE 7.5 8.0 8.0 6.5 6.9 7.0 4.1 4.4 4.6 -------------------~------------------------------------------------------------- 4-C-22 ~ Table 4-C-6.Cent. -OCTOBER 1982 - --------.----------.--------------------------------------------------~--------- r TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 I PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------.---------------~-------------------------------------- 0001 -0600 4.6 4.6 4.6 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 0601 -1200 4.6 4.6 4.6 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 1201 -1800 4.6 4.6 4.6 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 1801 -2400 4.6 4.6 4.6 1.2 1.5 1.7 .2 .2 .2 .2 .2 .2 DAILY VALUE 4.6 4.6 4.6 1.2 1.3 1.7 .2 .2 .2 .2 .2 .2 0001 -0600 4.1 4.1 4.1 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 0601 -1200 4.1 4.1 4.1 1.2 1.2 1.2 .2 .2 .2 .2 ---.2 1201 -1800 4.1 4.1 4.1 1.2 1.5 1.7 .2 .2 .2 -_.---- 1801 -2400 4.1 4.1 4.1 1.2 1.4 1.7 .2 .2 .2 --------- DAILY VALUE 4.1 4.1 4.1 1.2 1.3 1.7 .2 .2 .2 .2 ---.2 0001 -0600 4.1 4.1 4.1 1.2 1.2 1.2 .2 .2 .2 -------- 0601 -1200 3.6 '3.8 4.1 1.2 1.2 1.2 .2 .2 .2 -------- 1201-1800 3.6 3.6 3.6 1.2 1.2 1.2 .2 .2 .2 ----------- 1801 -2400 3.6 3.6 3.6 1.2 1.2 1.2 .2 .2 .2 --------- DAILY VALUE 3.6 3.8 4.1 1.2 1.2 1.2 .2 .2 .2 --------- ~~~0001 -0600 3.6 3.6 3.6 1.2 1.2 1.2 .2 .2 .2 ----...------ I 0601 -1200 2.6 2.9 3.1 .7 .7 .7 .2 .2 .2 -------- 1201 -1800 3.1 3.1 3.2 1.2 1.2 1.2 .2 .2 .2 ---------- 1801 -2400 2.7 2.9 3.2 1.2 1.2 1.2 .2 .2 .2 ---------- DAILY VALUE 2.6 3.1 3.6 .7 1.1 1.2 .2 .2 .2 -------._-- 0001 -0600 2.2 2.2 2.2 1.2 1.2 1.2 .2 .2 .2 -------- 0601 -1200 1.7 1.7 1.7 .7 .7 .7 .2 .2 .2 ---------- 1201 -1800 1.7 2.0 2.2 .7 .7 .7 .2 .2 .2 ------ ---- 1801 -2400 1.7 1.9 2.2 .7 .7 .7 .2 .2 .2 ----------- DAILY VALUE 1.7 1.9 2.2 .7 .8 1.2 .2 .2 .2 ---------- ~-0001 -0600 1.2 1.5 1.7 .7 .7 .7 .2 .2 .2I ------------ i 0601 -1200 1.2 1.2 1.2 .7 .7 .7 .2 .2 .2 ----------- 1201 -1800 1.2 1.5 1.7 .7 .7 .7 .2 .2 .2 ---------- 1801-2400 1.7 1.7 1.7 .7 .7 .7 .2 .2 .2 ----------,." DAILY VALUE 1.2 1 .5 1.7 .7 .7 .7 .2 .2 .2 --------- 0001 -0600 1.7 1.7 1.7 .2 .5 .7 .2 .2 .2 ----------- 0601 -1200 1.2 1'.4 '1.7 .2 .2 .2 .2 .2 .2 ---------- 1201 -1800 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 ----------- 1801 -2400 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 ---------- DAILY VALUE 1.2 1.4 1.7 .2 .3 .7 .2 .2 .2 ------------ 0001 ...0600 .7 .7 .7 .2 .2 .2 .2 .2 .2 -------------- 0601 -1200 .7 .9 1.2 .2 .2 .2 .2 .2 .2 MONTHLY VALUE 1201 -1800 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 -------------- 1801 -2400 1.2 1.2 1.2 .2 .2 .2 .2 .2 .2 .2 1.2 4.6 DAILY VALUE .7 1.0 1.2 .2 .2 .2 .2 .2 .2 ,...,-------------------------------------------------------------------------------- I II I r 4-C-23 -. Table 4-c-7.Thermograph data summary,summer surface water temperature (C),-LRX I,RM 97.0,Geocode S26N05W23DCB. -JUNE 1982 - ---------------------------------------------------------~----------~-----------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX HIN MEAN MAX ~------------------------------------------------------------------------~------ 0001 -0600 ----------7.6 7.6 7.6 6.1 6.1 6.1 ------- 0601 -1200 ----------7.1 7.3 7.6 6.1 6.3 6.6 -------- 1201 7.6 7.6 7.6 7.1 7.6 8.1 --1800 ---------------------- 1801 -2400 ---------7.1 7.4 7.6 8.6 8.9 9.1 ---------- DAILY VALUE ----------7.1 7.5 7.6 6.1 7.2 9.1 --------- ~ 0001 -0600 ----------6.6 6.9 7.1 8.6 8.9 9.1 ------- 0601 -1200 -----6.6 6.6 6.6 8.1 8.1 8.1 -------- 1201 -1800 -----------6.6 6.8 7.1 8.1 8.1 8.1 ----'II1II---- 1801 -2400 -------7.6 7.6 7.6 8.6 8.9 9.1 ---------DAILY VALUE ----------6.6 7.0 7.6 8.1 8.5 9.1 ----------- 0001 -0600 ------6.6 6.8 7.1 7.6 8.1 8.6 ---'II1II---- 0601 -1200 -------6.6 6.6 6.6 7.6 7.6 7.6 --------- 1201 -1800 --- --- ---6.6 6.6 6.6 8.6 9.1 9.6 --------- 1801 -2400 -----------6.6 6.6 6.6 10.1 10.1 10.1 --------- DAlLY VALUE ------6.6 6.6 7.1 7.6 8.7 10.1 ----------'""" 0001 -0600 ------6.6 6.6 6.6 9.6 9.8 10.1 ----------- 0601 -1200 -----------6.6 6.6 6.6 8.6 8.8 9.1 --------- 1201 -1800 ----------6.6 6.6 6.6 7.6 7.9 8.1 ----------~.-1801 -2400 -----------6.6 6.9 7.1 7.6 7.6 7 •.6 --..------ DAlLY VALUE ---------6.6 6.7 7.1 7.6 8.5 10.1 --------- 0001 -0600 -----------6.6 6.6 6.6 6.6 7.1 7.6 -------~, 0601 -1200 ---------6.6 6.6 6.6 6.6 6.8 7.1 -------- 1201 -1800 --------6.6 7.1 7.6 7.6 7.8 8.1 --------- 1801 -2400 ---- ------7.6 7.6 7.6 8.6 8.6 8.6 --------- DAlLY VALUE 6.6 7.0 7.6 6.6 7.6 8.6 ---------------- 0001 -0600 --------7.1 7.4 7.6 8.1 8.4 8.6 --------- 0601 -1200 ----------6.6 6.6 6.6 7.6 7.6 7.6 -----..~ 1201 -1800 -------~-7.6 8.1 8.6 8.1 8.4 8.6 --------- 1801 -2400 -------8.6 8.6 8.6 9.1 9.3 9.6 --------- DAlLY VALUE --- --- ----6.6 7.7 8.6 7.6 8.4 9.6 ----------0001 -0600 ---------8.6 8.6 8.6 8.6 9.1 9.6 -------- 0601 -1200 -----------7.6 7.8 8.1 7.6 7.9 8.1 --------- 1201 -1800 -----------7.1 7.3 7.6 8.6 9.1 9.6 --------- 1801 -2400 ---------6.6 6.8 7.1 9.6 9.6 9.6 -----------DAlLY VALUE ----------6.6 7.6 8.6 7.6 8.9 9.6 --------- 0001 -0600 ------5.6 5.9 6.1 9.1 9.4 9.6 -------------- 0601 1200 5.6 5.6 5.6 8.6 8.6 8.6 MONTHLY VALUE ------------- 1201 -1800 7.1 7.3 7.6 5.6 5.6 5.6 9.6 9.6 ------------- 1801 -2400 7.6 7.6 7.6 5.6 5.6 5.6 ----------5.6 ---10.1 DAILY VALUE 7.1 7.6 5.6 5.7 6.1 8.6 ---9.6 - ------------------------------------------~------------------------------------- 4-C-24 Table 4--C-8.Thermograph data summary,summer surface water temperature (C), Talkeetna River,RM 97.2.TRM 1.5.GeocodeS26N05W24BDA. -JUNE 1982 - ---------------------------------------------------------------------~----------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ---------------------------------------------------------------~--------- 0001 -0600 --------6.9 6.9 6.9 5.9 5.9 5.9 ------- ---- 0601 -1200 ---------6.4 6.4 6.4 5.9 6.1 6.4 --------- 1201 -1800 ---"'--.---6.4 6.4 6.4 7.4 8.2 8.9 -----_......--- 1801 -2400 --------6.9 6.9 6.9 9.4 9.4 9.4 ----------- DAILY VALUE -------6.4 6.6 6.9 5.9 7.4 9.4 ------- ---- 0001 -0600 ---------6.9 6.9 6.9 8.4 8.6 8.9 ---------..,.,- 0601 -1200 ----------6.9 6.9 6.9 7.9 7.9 7.9 -------- 1201 -1800 --------6.9 6.9 6.9 7.9 7.9 7.9 ----------- 1801 -2400 ------6.9 6.9 6.9 7.9 7.9 7.9 -------..--- DAILY VALUE ----------6.9 6.9 6.9 7.9 8.1 8.9 ----------- 0001 -0600 --------6.4 6.7 6.9 7.4 7.6 7.9 ---------- 0601 -1200 ------5.9 6.1 6.4 7.4 7.4 7.4 ------,--- 1201 -1800 --_.-------6.4 6.4 6.4 8.4 8.9 9.4 --------_..sl..._ 1801 -2400 -------6.4 6.4 6.4 9.4 9.4 9.4 ---------- DAILY VALUE ---------5.9 6.4 6.9 7.4 8.3 9.4 ----------- 0001 -0600 - -----6.4 6.4 6.4 8.9 9.2 9.4 ----------~, 0601 -1200 ---------6.4 6.4 6.4 7.4 7.9 8.4 ----------- 1201 -1800 -----6.4 6.4 6.4 6.9 7.2 7.4 -------- 1801 -2400 -------6.4 6.4 6.4 6.4 6.4 6.4 ---------- DAILY VALUE ---------6.4 6.4 6.4 6.4 7.7 9.4 --------- 0001 -0600 -----------6.4 6.4 6.4 6.4 6.4 6.4 ---------- 0601 -1200 -------5.9 6.1 6.4 6.4 6.6 6.9 ----------- 1201 -1800 ---------6.4 6.7 6.9 7.4 7.4 7.4 ----------- 1801 -2400 -----6.9 6.9 6.9 7.9 7.9 7.9 --------- DAILY VALUE ---------5.9 6.5 6.9 6.4 7.1 7.9 ----------- 0001 -0600 --- -------6.9 6.9 6.9 7.9 7.9 7.9 ------------ 0601 -1200 ----------6.9 7.1 7.4 7.4 7.6 7.9 ------- ---- 1201 -1800 ----------8.4 8.9 9.4 8.4 8.9 9.4 ----------- 1801 -2400 -----------8.9 9.1 9.4 8.9 9.2 9.4 ---------,-- DAILY VALUE ----------6.9 8.0 9.4 7.4 8.4 9.4 ---- ------- 0001 -0600 ----------7.9 8.2 8.4 8.4 8.6 8.9 ----------- 0601 -1200 --------7.4 7.6 7.9 8.4 8.4 8.4 ------------ 1201 -1800 ---------6.4 6.6 6.9 8.9 9.6 10.4 ----------- 1801 -2400 ---------6.4 6.4 6.4 10.4 10.4 10.4 --------- DAILY VALUE -----------6.4 7.2 8.4 8.4 9.2 10.4 ---------- 0001 -0600 -------5.9 5.9 5.9 9.4 9.9 10.4 -------------0601 -1200 ------5.9 5.9 5.9 9.4 9.4 9.4 MONTHLY VALUE 1201 -1800 6.4 6.6 6.9 5.9 5.9 5.9 9.4 ----9.4 ---------------1801 -2400 6.9 6.9 6.9 5.9 5.9 5.9 ---------5.9 ---10.4 DAILY VALUE 6.4 ----6.9 5.9 5.9 5.9 9.4 -~..-10.4,~ -------------------------------------------------------------------------------- 4-C-25 Table 4-C-8.Cant. -JULY 1982 - ------------------------------------------------------------------------------- ---------------------------------------------------~------------------------- TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX ...., 9.0 ----9.5 MONTHLY VALUE --.__._.- 0001 0600 0601 1200 1201 1800 --1801 2400 DAILY VALUE 0001 0600 ---- 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 ---- 1801 2400 DAILY VALUE --- 0001 0600 OpOl 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 --- 0601 1200 1201 1800 1801 2400 DAILY VALUE 9.0 9.0 9.0 9.0 9.2 9.3 9.0 9.5 9.5 9.5 -------------------------------------------------------------------------------- 4-C-26 r Table4-C-8.Cant. 4-C-27 Table 4-C-8.Cont. -OCTOBER 1982 - ~---------------------------------------------------------------------------TIME DAYS 1 -8'DAYS'9 ...16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN·MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX --------------------------------------------------------------------------- 0001 -0600 4.1 4.4 4.6 1.6 1.6 1.6 .1 .1 .1 ---------- 0601 -1200 4.1 4.1 4.1 1.6 1.8 2.1 .1 .4 .6 --------- 1201 -1800 4.1 ,4.1 4.1 2.1 2.1 2.1 .6 .8 1.1 ---------- 1801 -2400 4.1 4.1 4.1 2.1 2.1 2.1 .1 .4 .6 ----------- DAILY VALUE 4.1 4.2 4.6 1.6 1.9 2.1 .1 .4 1.1 -------- 0001 -0600 4.1 4.1 4.1 2.1 2.1 2.1 .1 .1 .1 ---------r 0601 -1200 4.1 4.1 4.1 1 ~6 1.6 1.6 .1 .1 .1 ---------- 1201 -1800 4.1 4.1 4.1 2.1 2.1 2.1 .1 .1 .1 ----------- 1801-2400 4.1 4.1 4.1 1.6 1.9 2.1 .1 .1 .1 ---------- DAILY VALUE 4.1 4.1 4.1 1.6 1.9 2.1 .1 .1 .1 ----------- 0001 -0600 3.6 3.9 4.1 1.6 1.6 1.6 .1 .1 .1 --------- 06.01 -1200 3.6 3.6 3.6 1.6 1.6 1.6 .1 .1 .1 ----------- 1201 -1800 4.1 4.1 4.1 1.6 1.6 1.6 .1 .1 .1 ------ ---- laol -2400 3.6 3.8 4.1 1.6 1.6 1.6 ~1 .1 .1 ---------- DAILY VALUE 3.6 3.8 4.1 1.6 1.6 1.6 .1 .1 .1 -------- 0001 -0600 2.6 2.9 3.1 1.1 1.4 1.6 .1 .4 .6 -----------'-"0601 1200 2.6 2 .6 2.6 1.1 1.1 1.1 .1 .3 .6--------- 1201 -1800 3.1 3.1 3.1 1.6 1.6 1.6 .6 .8 1.1 ------- 1801 -2400 2.6 2.9 3.1 2.1 2.1 2.1 .1 .1 .1 ------- DAILY VALUE 2.6 2.9 3.1 1.1 1.6 2.1 .1 .4 1.1 --'-------- 0001 -0600 2.1 2.1 2.1 1.6 1.6 1.6 .1 .1 .1 ---------,- 0601 -1200 1.6 1.6 1.6 1.1 1.1 1.1 .1 .1 .1 ---------r 1201 -1800 2.1 2.1 2.1 1.1 1.1 1.1 .1 .1 .1 ----------- 1801 -2400 1.6 1.9 2.1 1.1 1.1 1.1 .1 .1 .1 ----------- DAILY VALUE 1.6 1.9 2.1 1.1 1.2 1.6 .1 .1 .1 ---------- 0001 -0600 1.1 1.4 1.6 1.1 1.1 1.1 .1 .1 .1 ---------- 0601 -1200 1.1 1.1 1.1 .6 .6 .6 .1 .1 .1 ----------- 1201 -1800 1.6 1.6 1.6 1.1 1.1 1.1 .1 .1 ------ ----r 1801 -2400 1.6 1.6 1.6 .6 .9 1.1 -------------------- DAlLY VALUE 1.1 1.4 1.6 .6 .9 1.1 .1 ---.1 ---------- 0001 -0600 1.6 1.6 1.6 .1 .4 .6 --- --- ---------------- 0601 -1200 1.1 1.4 1.6 .1 .1 .1 ----------------------- 1201 -1800 1.1 1.3 1.6 .1 .1 .1 -------------------- 1801.-2400 1.6 1.6 1.6 .1 .1 .1 --------------------- DAILY VALUE 1.1 1.5 1.6 .1 .2 .6 ----------------------- 0001 -0600 1.6 1.6 1.6 .1 .1 .1 -------------------- 0601 -1200 1.6 1.6 1.6 .1 .1 .1 ------------MONTHLY VALUE 1201 -1800 2.1 2.1 2.1 .1 .1 .1 ---- ----------------------r 1801 -2400 1.6 1.9 2.1 .1 .1 .1 ---------.1 1.5 4.6 I DAILY VALUE 1.6 1.8 2.1 .1 .1 .1 ---------""--...... -------------------------------------~------------------------------------------,..... 4-C-29 Table 4-C-9.Thermograph data summary,summer surface water temperature (C),~Chulitna River,RM 98.6,TRM 0.6 ,Geocode S26NOSW14CBC. "",wee, -JUNE 1982 -~-------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------~ 0001 -0600 ---------6.0 6.3 6.5 5.5 5.5 5.5 --------- 0601 -1200 -------6.0 6.0 6.0 5.5 5.5 5.5 ----- 1201 -1800 --------5.0 5.5 6.0 5.5 5.5 5.5 --------~ 1801 -2400 -------5.0 5.0 5.0 5.5 5.7 6.0 ---------- DAILY VALUE ---------5.0 5.7 6.5 5.5 5.5 6.0 ---------- 0001 -0600 --------5.0 5.0 5.0 6.0 6.0 6.0 ------- 0601 -1200 ------5.0 5.0 5.0 6.0 6.0 6.0 ------- 1201 -1800 -------5.0 5.2 5.5 6.0 6.0 6.0 ---- 1801 -2400 ------5.5 5.5 5.5 6.0 6.0 6.0 -------- DAILY VALUE ----------5.0 5.2 5.5 6.0 6.0 6.0 ------- 0001 -0600 --------5.5 5.5 5.5 6.0 6.0 6.0 ------- 0601 -1200 ------5.5 5.5 5.5 6.0 6.0 6.0 ------,... 1201 -1800 --------5.5 5.5 5.5 6.0 6.0 6.0 ------ 1801 -2400 -------5.5 5.5 5.5 6.0 6.0 6.0 ------ DAILY VALUE ----5.5 5.5 5.5 6.0 6.0 6.0 ------ 0001 -0600 --------5.5 5.5 5.5 6.0 6.0 6.0 -------- 0601 -1200 ---------5.5 5.5 5.5 6.0 6.0 6.0 ----- 1201 -1800 --------5.5 5.5 5.5 6.0 6.0 6.0 ------- 1801 2400 5.5 5.5 5.5 6.0 6.0 6.0 ~."'"l----- - -------- DAILY VALUE -------5~5 5.5 5.5 6.0 6.0 6.0 -------- 0001 -0600 --------5.5 5.5 5.5 5.0 5.2 5.5 -------- 0601 -1200 -------5.5 5.5 5.5 5.0 5.3 5.5 ------- 1201 -1800 --------5.5 5.5 5.5 6.0 6.3 6.5 ------ 1801 -2400 ---------5.5 5.8 6.0 6.5 6.5 6.5 ----- DAILY VALUE --------5.5 5.6 6.0 5.0 5.8 6.5 ---------~ 0001 -0600 ------6.0 6.0 6.0 6.5 6.5 6.5 ------- 0601 -1200 ----------6.0 6.0 6.0 6.5 6.5 6.5 ------ 1201 1800 6.0 6.3 6.5 6.5 6.5 6.5 ~--------------------- 1801 -2400 ------7.0 7.0 7.0 6.5 6.5 6.5 --------- DAILY VALUE -------6.0 6.3 7.0 6.5 6.5 6.5 ---------- 0001 -0600 ---------7.0 7.0 7.0 6.5 6.5 6.5 --------- 0601 -1200 -----6.5 6.8 7.0 6.5 6.5 6.5 -------- 1201 -1800 ------------6.5 6.5 6.5 6.5 6.5 6.5 -------- 1801 -2400 --------6.0 6.0 6.0 6.5 6.5 6.5 ------------DAILY VALUE -----------6.0 6.6 7.0 6.5 6.5 6.5------------ 0001 -0600 ---------5.5 5.8 6.0 6.5 6.5 6.5 ------------ 0601 -1200 -------5.5 5.5 5.5 6.5 6.7 7.0 MONTHLY VALUE 1201 -1800 6.5 6.5 6.5 5.5 5.5 5.5 --------------------- 1801 -2400 7.0 7.0 7.0 5.5 5.5 5.5 ------ ----5.0 --7.0 DAILY VALUE 6.5 --7.0 5.5 5.6 6.0 6.5 ---7.0 -------------------------------------------------------------------------------- """I 4-C-30 - Tab1e4-C-9.Cont. -AUGUST 1982 - --------------------------------------------------------------------------------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 --------------------- --- 6.5 6.7 7.0 0601 -1200 ------------------- --- 7.0 7.0 7.0 1201 -1800 ----------------------7.0 7.0 7.0 1801 -2400 -------------------------6.5 6.7 7.0 DAILY VALUE ---------._-----------------6.5 6.8 7.0 0001 -0600 ------------------~-----------6.0 6.3 6.5 0601 -1200 --- ------------------------5.5 5.7 6.0 1201 -1800 ---------------------------5.5 5.5 5.5 1801 -2400 --------------- ---------5.5 5.5 5.5 DAILY VALUE -------- -------------------------5.5 5.7 6.5 0001 -0600 - - ------------------------6.0 6.0 6.0 0601 -1200 -----------------------------6.0 6.2 6.5 1201 -1800 ---- -----------------------6.5 6.5 6.5 1801 -2400 -------------- ----------6.5 6.5 6.5 DAlLY VALUE --------------------------6.0 6.3 6.5 0001 -0600 ----------------------------6.5 6.5 6.5r"'-"0601 -1200 ---------------------------6.0 6 ~3 6.5 1201 -1800 ------------------------5.5 5.8 6.0 1801 -2400 --------------------- ---- 5.5 5.5 5.5 DAILY VALUE --------------------------------5.5 6.0 6.5 0001 -0600 ----------------------------5.5 5.5 5.5 0601 -1200 ----------------------------5.5 5.8 6.0 1201 -1800 ---------------------------6.0 6.0 6.0 1801 ;"'2400 -------------------------------6.5 6.5 6.5 DAILY VALUE ------------.---------_.-----5.5 6.0 6.5 0001 -0600 ---------------------1"""---6.5 6.5 6.5 0601 -1200 -------------------------------6.5 6.5 6.5 1201 -1800 -------------------------------6.5 6.5 6.5 1801--2400 ----------------------7.5 7.5 7.5 6.0 6.0 6.0 DAILY VALUE -----------------7.5 ---7.5 6.0 6.4 6.5 0001 -0600 -----------------------7.5 7.5 7.5 5.5 5.5 5.5 0601 -1200 --------------------7.5 7.8 8.0 5.5 5.5 5.5 1201 -1800 ---- --------------------7.5 7.5 7.5 5.5 5.8 6.0 1801 -2400 --------------------7.0 7.2 7.5 6.0 6 ".2 6.5 DAILY VALUE ---------------------7.0 7.5 8.0 5.5 5.7 6.5 0001 -0600 ----------------------6.5 6.5 6.5 --------------0601 -1200 ---------------------6.5 6.5 6.5 MONTHLY VALUE 1201 -1800 ------------------6.5 6.5 6.5 -------------r 1801 -2400 -------------------6.5 6.5 6.5 5.5 ---8.0 DAILY VALUE --------------------6.5 6.5 6.5 ---------------~------------------~---------------------------------------------rI 4-C-31 Tab1e4-C-9.Cont. -OCTOBER,1982 - ------------------------------------------------------------------------~------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX.MIN MEAN MAX MIN MEAN MAX.MIN MEAN MAX ------------------------------------------------------------------------------ 0001 -0600 ---- -----------------0.0 0.0 0.0 ------------ 0601 -1200 --------------0.0 0.0 0.0 -------- 1201 -1800 -------'--1.0 1.2 1.5 0.0 0.0 0.0 ----------- 1801 -2400 -----------1.5 1.5 1.5 0.0 0.0 0.0 ---------- DAILY VALUE -----------1.0 ----1.5 0.0 0.0 0.0 ----------- 0001 -0600 ---- -------1.5 1.5 1.5 0.0 0.0 0.0 ---------- 0601 -1200 -------1.5 1.5 1.5 0.0 0.0 0.0 -------- ---- 1201 -1800 -------1.5 1.5 1.5 0.0 0.0 0.0 --------- 1801 -2400 -------1.0 1.2 1.5 0.0 0.0 0.0 --------- DAILY VALUE -----------1.0 1.4 1.5 0.0 0.0 0.0 ---------- 0001 -0600 ---------1.0 1.0 1.0 0.0 0.0 0.0 ------------ 0601 -1200 -------1.0 1.0 1.0 0.0 0.0 0.0 --------- 1201 -1800 ---------1.0 1.0 1.0 0.0 0.0 0.0 --- --- ---- 1801 -2400 ------ --- .5 .7 1.0 0.0 0.0 0.0 ----------- DAILY VALUE ------.5 .9 1.0 0.0 0.0 0.0 -------- 0001 -0600 ------------.5 .5 .5 0.0 0.0 0.0 --------- ,~~,0601 -1200 ----------0.0 .2 .5 0.0 0.0 0.0 -------- 1201 -1800 ----------.5 .5 .5 0.0 0.0 0.0 ------------ 1801 -2400 ------ --- .5 .5 .5 0.0 0.0 0.0 ----------- DAILY VALUE ---------0.0 .4 .5 0.0 0.0 0.0 ----------- 0001 -0600 ---------.5 .5 .5 0.0 0.0 0.0 ------- --- 0601 -1200 -----------0.0 0.0 0.0 0.0 0.0 0.0 ------------ 1201 -1800 ----------0.0 0.0 0.0 0.0 0.0 0.0 ----------- 1801 -2400 --------0.0 0.0 0.0 0.0 0.0 0.0 ------------ DAILY VALUE ---------0.0 .1 .5 0.0 0.0 0.0 ------- ---- 0001 -0600 --------0.0 0.0 0.0 0.0 0.0 0.0 ------....----- 0601 -1200 ----------0.0 0.0 0.0 0.0 0.0 0.0 ------------ 1201 -1800 -------0.0 0.0 0.0 0.0 ---0.0 ---------- 1801 -2400 --- --- ---0.0 0.0 0.0 ------------------- DAILY VALUE ----------0.0 0.0 0.0 0.0 ---0.0 ----.------- 0001 -0600 ----------0.0 0.0 0.0 --------------------- 0601 -1200 ----------0.0 0.0 0.0 ---------------------- 1201 -1800 -----------0.0 0.0 0.0 ---------------------- 1801 -2400 ------------0.0 0.0 0.0 ----------------------- DAILY VALUE ------------0.0 0.0 0.0 ---------------------- 0001 -0600 --- --- ----0.0 0.0 0.0 ------------------------ 0601 -1200 ----------0.0 0.0 0.0 ----------MONTHLY VALUE 1201 -1800 ---------0.0 0.0 0.0 ------------------------1801 -2400 ----------0.0 0.0 0.0 -----------0.0 ---loS DAILY VALUE ----------0.0 0.0 0.0 ----------- -------------------------------------------------------------------------------- 4-C-33 Table 4-C-IO.Thermograph data summary,summer surface water temperature (C), Talkeetna Fishwhee1,RM 103.0,Geocode S27N05W26DDD. -JUNE 1982 - ------------------------------------------------------------------------------- - ..... -------------------------------------------------------------------------------- TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 ...24 MIN·MEAN MAX DAYS 25 -31 MIN MEAN MAX -. 0001 -0600 ----------------------------12.1 12.3 12.6 0601 -1200 ------ -------------------12.1 12.4 13.1 1201 -1800 ---------------------------13.6 13 .8 14.1 1801 -2400 -----------------------------13.1 13.6 14.1 DAILY VALUE ------- ---------------- --- 12.1 13.0 14.1 0001 -0600 -------------- --------------12.6 12.8 13.1 0601 -1200 ---- ---------------------..------12.6 12 .8 13.1 1201 -1800 ---------------------------13.6 13.6 13 .6 1801 -2400 ----------------------------------13.6 13.6 13.6 DAILY VALUE ------~-------------------------12.6 13 .2 13.6 0001 -0600 ---------------------------12.6 13 .1 13.6 0601 -1200 -------.---------- -----------.---12.6 12.6 12.6 1201 -1800 --- ---------------------12.6 12.9 13 .1 1801 -2400 ------- ----------------------12.6 12.6 12.6 DAILY VALUE ------ -------- --------------12.6 12.8 13.6 0001 -0600 ------~---------------------12.6 12.6 12.6 0601 -1200 -------------------------12.6 12.6 12.6 1201 -1800 ------------------------12.6 12.6 12.6 1801 -2400 ----------------------------12.6 12.6 12.6 DAILY VALUE ----------------------- ---- 12.6 12.6 12.6 0001 -0600 ---------------------------12.1 12.1 12.1 0601 -1200 ------ - ----------------11.6 11.6 11.6 1201 -1800 ------------------------------12.1 1.2.1 12.J 1801 -2400 ---------------------- --------12.1 12.1 12.1 DAILY VALUE ---------------------------11.6 12.0 12.1 0001 -0600 -------------------------ILl 1L4 1L6 0601 -1200 -------------- -----------------ILl 1L4 11.6 1201 -1800 ----------------------------11.6 11.9 12.1 1801 -2400 ------------------------------11.1 11.4 11.6 DAILY VALUE -----------------------------11.1 11.6 12.1 0001 -0600 ------------------------- ------------- 0601 -1200 ------------------------------------------ 1201 -1800 ------------------------------- ------- 1801 -2400 ---------------------------------- -------- DAILY VALUE ------------------------------------------ 0001 -0600 ------------------------------------------0601 -1200 ----------------------------MONTHLY VALUE 1201 -1800 --------------------12.6 12.9 13.1 -----------1801 -2400 ---------------------12.6 12.9 13.1 11.1 ---14.1 DAILY VALUE ----------------------12.6 ----13 .1 -------------------------------------------------------------------------------- 4-C-34 Table 4-C-10.Cont. -JULY 1982 - r 1 TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9-16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX F' I 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 10.6 10.811.1 10.6 10.8 11.1 11.111.3 11.6 10.1 10.6 11.1 10.1 10.8 11.6 9.6 9.9 10.1 9.6 9.9 10.1 10.6 10.9 11.1 10.6 10.9 11.1 9.6 10.4 11.1 12.4 12.6 12.9 12.412.913.4 13.9 13.9 13.9 13.913.9 13.9 12.4 13.3 13.9 12.9 13.1 13.4 12.4 12.6 12.9 11.9 12.1 12.4 11.4 11.7 11.9 11.4 12.4 13.4 9.9 9.9 9.9 9.4 9.9 10.4 10.9 11.2 11.4 10.4 10.7 11.4 9.4 10.4 11.4 10.4 10.4 10.4 10.4 10.4 10.4 10.9 10.9 10.9 10.4 10.6 10.9 10.4 10.6 10.9 9.4 9.4 9.4 9.4 9.4 8.9 8.9 9.9 9.4 8.9 9.4 9.4 9.4 9.4 9.4 9.1 9.1 9.9 9.6 9.4 9.4 9.4 9.4 9.4 9.4 9.4 9.4 9.9 9.9 9.9 r I 0001 -0600 8.6 9.3 10.1 0601 -1200 ---- -------- 1201 -1800 ---- -------- 1801 -2400 ---- -------- DAILY VALUE 8.6 ----10.1 0001 -0600 ---- -------- 0601 -1200 ------------ 1201 -1800 ------ ---- 1801 -2400 ---------- DAILY VALUE -------- 0001 -0600 ---- -------- 0601 -1200 -------- ---- 1201 -1800 -------- ---- 1801 -2400 ---- -------- DAILY VALUE ----------- 0001 -0600 ---- -------- .0601 -1200 ------ ---- 1201 -1800 ---------- 1801 -2400 ---------- DAILY VALUE ---- -------- 0001 ~0600 ---- ---- ---- 0601 -1200 ------ ---- 1201 -1800 14.9 14.9 14.9 1801 -2400 13.4 13.9 14.4 DAILY VALUE 13.4 ----14.9 11.4 11.4 11.4 11.411.411.4 11.411.411.4 10.9 11.1 11.4 10.9 11.3 11.4 10.4 10.4 10.4 10.4 10.7 10.9 10.9 11.2 11.4 10.9 11.1 11.4 10.4 10.9 11.4 10 •9 10 •9 10 .9 10.9 11.1 11.4 11.9 11.9 11.9 11.4 11.6 11.9 10.9 11.4 11.9 10.9 10.9 10.9 11.411.411.4 11.4 11.7 11.9 11.411.411.4 10.9 11.4 11.9 10.9 10.9 10.9 10.4 10.7 10.9 10.9 10.9 10.9 10.9 1O~9 10.9 10.4 10.9 10.9 9.9 9.9 9.9 10.4 11.2 11.9 12.4 12.7 12.9 11.9 12.1 12.4 9.9 11.5 12.9 11.4 11.6 11.9 11.9 12.6 13.4 13.9 14.1 14.4 13.413.7 13.9 11.4 13.0 14.4 '12.9 13.1 13.4 12.9 13.2 13.4 12.9 13.2 13.4 12.4 12.6 12.9 12.4 13.0 13.4 11.9 12.1 12.4 11.9 12.2 12.4 12.4 12.4 12.4 11.9 11.9 11.9 11.9 12.1 12.4 10.9 11.1 11.4 10.9 10.9 10.9 10.9 10.9 10.9 10.4 10.4 10.4 10.4 10.8 11.4 9.4 9.6 9.9 9.9 10.2 10.4 10.9 10.9 10.9 10.4 10.4 10.4 9.4 10.3 10.9 10.4 10.4 10.4 10.4 11.1 11.9 12.4 12.4 12.4 11.9 11.9 11.9 10.4 11.4 12.4 11.9 11.9 11.9 11.9 11.9 11.9 11.9 12.1 12.4 11.4 11.6 11.9 11.4 11.9 12.4 10.9 11.211.4 10.9 10.9 10.9 10.9 10.9 10.9 10.4 10.6 10.9 10.4 10.9 11.4 9.9 9.9 9.9 9.9 10.4 10.9 10.9 11.2 11.4 10.4 10.4 10.4 9.9 10.5 11.4 0001 -0600 12.4 12.7 12.9 0601 -1200 12.9 13.2 13.4 1201 -1800 13.9 13.9 13.9 1801 -2400 12.9 13.2 13.4 DAILY VALUE 12.4 13.3 13.9 10.4 10.4 10.4 10.4 10.4 10.4 10.9 10.9 10.9 10.4 10.6 10.9 10.4 10.6 10.9 4-C-35 9.9 9.9 9.9 --------------- 9.9 9.9 9.9 MONTHLY VALUE 9.9 9.9 9.9 --------------- 9.9 9.9 9.9 8.6 11.3 14.9 9.9 9.9 9.9 4-C-36 - r I Table 4-C-10.Cont. 4-C-37 Table 4-C-IO.Cont.- ~.. -OCTOBER 1982 -~ ------------------------------------------------------~-------------------------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ---------------------------------------------------------~---------------------- 0001 -0600 4.9 4.9 4.9 .9 .9 .9 .2 .2 .2 .2 .2 .2 0601 -1200 4.4 4.4 4.4 .9 .9 .9 .2 .2 .2 .2 .2 .2 -1201 -1800 4.9 4.9 4.9 .9 .9 .9 .2 .2 .2 .2 .2 .2 1801 -2400 4.4 4.7 4.9 .9 .9 .9 .2 .2 .2 .2 .2 .2 DAILY VALUE 4.4 4.7 4.9 .9 .9 .9 .2 .2 .2 .2 .2 .2 ~ 0001 -0600 3.9 4.2 4.4 ------.2 .2 .2 .2 .2 .2 0601 -1200 3.9 3.9 3.9 1.2 --1,2 .2 .2 .2 .2 .2 .2 1201 -1800 4.4 4.4 4.4 1.2 1.2 1.2 .2 .2 .2 .2 --.2 1801 -2400 4.4 4.4 4.4 .7 1.0 1.2 .2 .2 .2 --------- DAILY VALUE 3.9 4.2 4.4 .7 ---1.2 .2 .2 .2 .2 ---.2 0001 -0600 3.9 4.1 4.4 .7 .7 .7 .2 .2 .2 -------- 0601 -1200 3.9 3.9 3.9 .7 .7 .7 ..2 .2 .2 -------- 1201 -1800 4.4 4.4 4.4 .7 .7 .7 .2 .2 .2 --.-----~~- 1801 -2400 3.9 4.2 4.4 .7 .7 .7 .2 ~2 .2 ----------- DAILY VALUE 3.9 4.1 4.4 .7 .7 .7 .2 .2 .2 ---------- 0001 -0600 3.4 3.7 3.9 .2 .5 .7 .2 .2 .2 ------ ---- 0601 -1200 2.9 2.9 2.9 .2 .2 .2 .2 .2 .2 -------- 1201 -1800 2.9 3.2 3.4 .7 .7 .7 .2 .2 .2 -----,--/~~ 1801 -2400 2.9 3.2 3.4 .7 .7 .7 .2 .2 .2 -------- DAILY VALUE 2.9 3.3 3.9 .2 .5 .7 .2 .2 .2 ---------- 0001 -0600 2.4 2.7 2.9 .2 .5 .7 .2 .2 .2 ------- 0601 -1200 1.9 1.9 1.9 .2 .2 .2 .2 .2 .2 ----- 1201 -1800 2.9 2.9 2.9 .2 .2 .2 .2 .2 .2 ------- 1801 -2400 2.4 2.6 2.9 .2 .2 .2 .2 .2 .2 -------- DAILY VALUE 1.9 2.5 2.9 .2 .3 .7 .2 .2 .2 ---------- 0001 -0600 1.9 2.1 2.4 .2 .2 .2 .2 .2 .2 ------- 0601 -1200 1.4·1.4 1.4 .2 .2 .2 .2 .2 .2 -.-------1""'1 1201 -1800 1.9 1.9 1.9 .2 .2 .2 .2 .2 .2 --------- 1801 -2400 1.9 1.9 1.9 .2 .2 .2 .2 .2 .2 ------ DAILY VALUE 1.4 1.8 2.4 .2 .2 .2 .2 .2 .2 ---------- 0001 -0600 1.9 1.9 1.9 .2 .2 .2 .2 .2 .2 ---------- 0601 -1200 1.4 1.6 1.9 .2 .2 .2 .2 .2 .2 ----------- 1201 -1800 1.4 1.4 1.4 .2 .2 .2 .2 .2 .2 ------- 1801 -2400 1.4 1.4 1.4 .2 .2 .2 .2 .2 .2 -------- DAILY VALUE 1.4 1.6 1.9 .2 .2 .2 .2 .2 .2 ---------- 0001 -0600 1.4 1.4 1.4 .2 .2 .2 .2 .2 .2 -----------"'!"'-!'JIB 0601 -1200 1.4 1.4 1.4 .2 .2 .2 .2 .2 .2 MONTHLY VALUE 1201 -1800 1.4 1.4 1.4 .2 .2 .2 .2 .2 .2 --------------- 1801 -2400 .9 1.1 1.4 .2 .2 .2 .2 .2 .2 .2 1.2 4.9 DAILY VALUE .9 1.3 1.4 .2 .2 .2 .2 .2 .2 ~ -------------------------~--------------------.--------------------------------- 4-C-38 I""'" Tab1e4-C-ll.Thermograph data summary.summer surface water temperature (C),"-LRX 18,RM 113.0.Geocode S28N04W12DAB. -JULY 1982 - ------------------------------------------------------------------------------TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------~------------------------------------------------------------ ~0001 -0600 -.-----13.7 13.7 13.7 10.2 10.4 10.7 9.2 9.2 9.2 0601 -1200 --------13.7 13.7 13.7 10.210.2 10.2 9.2 9.2 9.2 .1201 -1800 -------14.2 14.5 14.7 10.7 11.2 11.7 9.2 9.2 9.2 1801 -2400 ----------14.2 14.5 14.7 11.2 11.4 11.7 9.2 9.2 9.2 DAILY VALUE --------13.7 14.1 14.7 10.2 10.8 11.7 9.2 9.2 9.2 0001 -0600 ----"-----13 .2 13 .5 13 .7 10.7 10.9 11.2 8.7 9.0 9.2 0601 -1200 ------12.7 13.0 13 .2 10.7 10.9 11.2 8.7 9.0 9.2 1201 -1800 ----------12.7 12.7 12.7 11.2 11.2 11.2 9.2 9.5 9.7 1801 -2400 -------'-12.2 12.4 12.7 11.2 11.2 11.2 9.2 9.4 9.7 DAILY VALUE ---- --------12.2 12.9 13.7 10.7 11.0 11.2 8.7 9.2 9.7 0001 -0600 ---11.7 12.0 12.2 10.7 10.7 10.7 9.2 9.5 9.7 0601 -1200 ----11.7 11.7 11.7 10.7 11.2 11.7 9.7 9.7 9.7 1201 -1800 -------11.7 11.9 12.2 12.2 12.5 12.7 10.2 10.2 10.2 ~.1801 -2400 --------11.2 11.5 11.7 12.2 12.5 12.7 10.2 10.2 10.2 DAILY VALUE ------11.2 11.812.2 10.7 11.7 12.7 9.2 9.9 10.2 0001 -0600 -------10.7 11.0 11.2 12.2 12.2 12.2 9.7 10.0 10.2 ~,,~.0601 -1200 11.2 11.2 11.2 12.2 12.4 12.7 10.2 10.4 10.7--------- 1201 -1800 ------11.7 11.7 11.7 13.7 14.0 14.2 11.2 1l.5 11.7 .UiOl -2400 -----11.2 11.5 11.7 13.7 14.0 14.2 11.7 11.7 11.7 DAILY VALUE ------10.7 11.411.7 12.2 13.2 14.2 9.7 10.9 11.7 .0001 -'0600 --------11.2 11.211.2 13 .7 13.7 13.7 11.2 11.5 11.7.. 11.2 11.4 11.7 11.'70601-1200 ------13.7 13 .7 13.7 11.7 11.7 1201 -1800 ---------11.7 12.0 12.2 13 .2 13.5 13.7 11.7 11.7 11.7 1801 -2400 ---------11.7 11.9 12.2 12.7 13 .0 13 .2 11.2 11.4 11.7 DAILY VALUE ---------11.2 11.6 12.2 12.7 13.5 13.7 11.2 11.6 11.7 ~0001 -0600 -------11.7 11.7 11.7 12.2 12.4 12.7 10.7 11.0 11.2 0601 -1200 ----------11.7 11.7 11.7 12.2 12.2 12.2 10.7 10.7 10.7 1201 -1800 -------11.7 12.0 12.2 ,12.7 12.7 12.7 10.7 10.7 10.7 1801 -2400 --------11.7 11.9 12.2 12.2 12.2 12.2 10.2 10.2 10.2.....DAILY VALUE -------11.7 11.8 12.2 12.2 12.4 12.7 10.2 10.7 11.2 0001 -0600 --------1L2 11.411.7 '11.2 11.4 11.7 9.7 9.7 9.7 ~0601 -1200 --------11.2 11.2 11.2 10.7 10.7 10.7 9.7 9.9 10.2 1201 -1800 -----------11.7 11.7 11.7 10.7 10.7 10.7 10.2 10.4 10.5 1801 -2400 14.2 14.7 15.2 11.2 11.4 11.7 10.2 10.4 10.7 9.5 9.8 10.0 DAILY VALUE 14.2 ---15.2 11.2 1l.411.7 10.2 10.8 11.7 9.5 9.9 10.5 0001 -0600 13.2 13.4 13,.7 10 .7 10.9 11.2 9.7 9.9 10.2 --------------0601 ...1200 13.2 13.7 14.2 10.7 10.9 11.2 9.7 9.7 9.7 MONTHLY VALUE 1201 -1800 14.2 14.2 14.2 11.2 11.2 1l.2 9.7 9.9 10.2 --------------.~1801 -2400 13.7 14.0 14.2 10.7 11.0 11.2 9.7 9.7 9.7 8.7 11.5 15.2 DAILY VALUE 13.2 13.8 14.2 10.7 11.0 11.2 9.7 9.8 10.2 4-C-39 Table 4-C-ll.Cont. ...AUGUST 1982 ... -~------------~------------------------------------------------------------------TIME PERIOD .DAYS 1 ...8 MIN MEAN MAX DAYS 9 -16 MIW MEAN MAX DAYS 17 ...24 MIN MEAN MAX DAYS 25 ...31 MIN MEAN MAX -----------------------------~~~~--~~--------------------.---~----------- 0001 ...0600 9.0 9.3 9.5 10.0 10.2 10.5 10.0 10.0 10.0 10.8 10.8 10.8 0601 ...120Q 9.0 9.2 9.5 10.0 10.0 10.0 10.0 10.0 10.0 10.8 10.8 10.8 Bllli! 1201 ...1800 10.0 10.3 10.5 10.0 10.0 10.0 10.3 10.3 10.3 10.8 11.1 11.3 1801 ...2400 9.5 10.0 10.5 9.S 9.8 10.0 9.8 10.0 10.3 10.3 10.8 11.3 DAILY VALUE 9.0 9.7 10.5 9.5 10.0 10.5 9.810.1 10.3 10.3 10.9 11.3 ~ 0001 -0600 9.0 9.2 9,5 9.0 9.3 9.5 8.8 9.1 9.3 ·10.3 10.3 10.3 0601 ...1200 9.0 9.5 10.0 9.0 9.2 9.5 8~8 9.1 9.3 10.3 10.3 10.3 1201 ...1800 10.5 10.5 10.5 9.5 9.5 9.5 9.8 9.8 9.8 10.8 11.1 11.3 1801 ...2400 10.0 10.3 10.5 9.5 9.5 9.5 9.3 9.6 9.8 10.3 10.8 11.3 -DAILY VALUE 9.0 9.9 10.5 9.0 9.4 9.5 8.8 9.4 9.8 10.3 10.6 11.3 0001 ...0600 9.5 9.5 9.5 9.0 9.0 9.0 9.3 9.3 9.3 9.3 9.5 9.8 ~ 0601 ...1200 9.5 9.8 10.0 9.0 9.2 9.5 9.3 9.5 9.8 8.8 9.3 9.8 1201 ...1800 10.5 10.811.0 10.0 10.3 10.5 10.3 10.6 10.8 10.3 10.6 10.8 1801 ...2400 10.5 10.7 11.0 9.5 10.0 10'.5 9.8 10.0 10.3 9.3 9.8 10.3 DAILY VALUE 9.5 10.2 11.0 9.0 9.6 10.5 9.3 9.8 10.8 8.8 9.8 10.8 0001 ...0600 9.5 9.7 10.0 9.0 9.2 9.5 9.3 9.3 9.3 8.8 9.0 9.3 0601 -1200 9.5 10.0 10.5 9.0 9.2 9.5 9.3 9.6 10.3 8.8 9.1 9.3 1201 ...1800 11.0 11.5 12.0 10.0 10.5 11.0 10.8 11.3 11,.8 9.8 10.1 10.3 ~ 1801 ...2400 11.0 11.3 11.5 10.0 10.1 10.5 10.8 11.3 11.8 9.8 10.0 10.3 DAILY VALUE 9.5 10.6 12.0 9.0 9.811.0 9.3 10.4 11.8 8.8 9.5 10.3 0001 ...0600 10.5 10 •.5 10.5 9.5 9.7 10.0 9.8 10.1 10.3 9.3 9.3 9.3 0601 ...1200 10.5 10.7 11.0 9.5 10.0 10.5 9.8 10.3 10.8 9.3 9.3 9.3 1201 ...1800 11.5 11.812,0 11.0 11.7 12.0 11.3 11.6 11.8 9.7 9.7 9.7 1801 ...2400 11.0 11.5 12.0 11.5 11.7 12.0 11.3 11.5 11.8 9.7 9.7 9.7 ""'"DAILY VALUE 10.5 11.1 12.0 9.5 10.7 12.0 9.8 10.9 11.8 9.3 9.5 9.7 0001 -0600 10.5 10,.5 10.5 11.0 11.0 11.0 9.8 10.1 10.3 9.2 9.2 9.2 0601 ...1200 10.5 10.811.5 11.0 11.0 11.0 9.8 10.1 10.3 9.2 9.2 9.2 -,. 1201 ...1800 11.5 11.8 12.0 11.5 11.5 11.5 11.3 11.6 11.8 9.2 9.2 9.2 1801 ...2400 11.5 11.7 12.0 11.0 11.3 11.5 11.3 11.5 11.8 9.2 9.2 9.2 DAILY VALUE 10.5 11.212.0 11.0 11.2 11.5 9.8 10.8 11.8 9.2 9.2 9.2 0001 ...0600 10.5 10.7 11.0 10.5 10.8 11.0 10.8 10.8 10.8 8.2 8.5 8.7 0601 ...1200 10.5 10.8 11.0 10.5 10.7 11.0 10.8 11.0 11.3 8.2 8.2 8.2 1201 -1800 11.0 11.3 11.5 11.5 11.5 11.5 11.3 11.3 11.3 8.2 8.5 8.7 1801 ...2400 10.5 10.811.0 11.0 11.3 11.5 11.3 11.3 11.3 8.2 8.4 8.7 DAILY VALUE 10.5 10.9 11.5 10.5 11.1 11.5 10.811.1 11.3 8.2 8.4 8.7 0001 -0600 10.0 10.3 10.5 10.5 10.5 10.5 10.8 10.8 10.8 ------------- 0601 ...1200 10.0 10.3 10.5 10.5 10.7 11.0 10.8 10.8 10.8 MONTHLY VALUE 1201 ...1800 11.5 11.5 11 .5 11.0 11.3 11.5 11.3 11.3 11.3 -------------- 1801 -2400 10.5 10.8 11.0 10.5 10.7 11.0 11.3 11.3 11.3 8.2 10.3 12.0 DAILY VALUE 10.0 10.7 11.5 10.5 10.8 n.s 10.8 11.0 11.3 ~ -------------------------------~------------------------------------------------ 4-C-40 Table 4-C-ll.Cont. -SEPTEMBER 1982 - -------------------------------------------------------------------------------- ~TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 8.2 8.2 8.2 8.2 8.2 8.2 7.2 7.2 7.2 4.0 4.3 4.5 0601 -1200 8.2 8.2 8.2 7.7 7.7 7.7 7.2 7.2 7.2 4.0 4.2 4.5 1201-1800 8.7 8.7 8.7 7.7 8.0 8.2 7.2 7.5 8.0 4.5 4.5 4.5 1SOl -2400 8.7 8.7 8.7 8.2 8.2 8.2 7.0 7.3 7.5 4.5 4.5 4.5 DAILY VALUE 8.2 8.4 8.7 7.7 8.0 8.2 7.0 7.3 8.0 4.0 4.4 4.5 0001 -0600 8.2 8.2 8.2 7.7 7.7 7.7 7.0 7.0 7.0 4.5 4~5 4.5 06()1 -1200 8.2 8.2 .8.2 7.7 7.7 7.7 7.0 7.0 7.0 4.5 4.5 4.5 .1201 -1S00 8.2 8.4 8.7 7.7 7.7 7.7 7.0 7.0 7.0 4.5 4.8 5.0 1801'"2400 8.2 8.5 8.7 7.7 7.7 7 .7 6.5 6.7 7.0 5.0 5.0 5.0 .DAILY VALUE 8.2 8.3 .~.7 7.7 7.7 7.7 6.5 6.9 7.0 4.5-4.7 5.0 0001-0600 8.2 8.2 8.2 7.2 7.5 7.7 6.5 6.5 6.5 5.0 5.0 5.0 0601 -1200 7.7 8.0 8.2 7.2 7.2 7.2 6.5 6.7 7.0 5.0 5.0 5.0 1201-1800 8.2 8.2 8.2 7.2 7.2 7.2 7.0 7.0 7.0 5.0 5.3 5.5-1801 -2400 8.2 8.2 8.2 6.7 7.0 7.2 6.5 6.8 7.0 5.0 5.2 5.5 DAILY VALUE 7.7 8.2 8.2 6.7 7.2 7.7 6.5 6.7 7.0 5.0 5.1 5.5 0001 ..0600 7.7 7.9 8.2 6.2 6.4 6.7 6.5 6.5 6.5 4.5 4.5 4.5 ~-~0601 -1200 7.7 7.7 7.7 5.7 5.7 5.7 6.5 6.5 6.5 4.0 4.3 4.5 1201 -1800 7.7 8.0 8.2 6.2 6.2 6.2 7.0 7.0 7.0 4.5 4.5 4.5 1801 -2400 7.7 8.0 8.2 6.2 6.2 6.2 6.5 6.7 7.0 4.5 4.5 4.5-DAILY VALUE 7.7 7.9 8.2 5.7 6.1 6.7 6.5 6~7 7.0 4.•0 4.5 4.5 0001 ..0600 7.2 7.5 7.7 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5 0601 -1200 7.2 7.2 7.2 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5 F-1201 -1S00 7.7 7.7 7.7 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5 1801 ..;,2400 7.7 7.7 7.7 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5 DAILY VALUE 7.2 7.5 7.7 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5 I"""0001 -0600 7.7 7.7 7.7 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5k 0601 .;.1200 7.7 7.7 7.7 6.2 6.2 6.2 6.5 6.5 6.5 4.5 4.5 4.5 1201 -1800 7.7 .7.7 7.7 6.2 6.4 6.7 6.5 6.5 6.5 4.5 4.5 4.5 1801 -2400 7.7 7.7 .7.7 6.7 6.7 6.7 6.0 6.2 6.5 4.5 4.5 4.5-DAILY VALUE 7.7 7.7 7.7 6.2 6.4 6.7 6.0 6.4 6.5 4.5 4.5 4.5 0001 -0600 7.7 7.7 7.7 6.2 6.5 6.7 5.5 5.5 5.5 ---------- 0601 -1200 7.7 7.7 7.7 6.2 6.4 6.7 5.5 5.5 5.5 ----------- 1201 -1800 8.2 8.2 8.2 7.2 7.2 7.2 5.5 5.7 6.0 ----------- 1801 -2400 8.7 8.7 8.7 7.2 7.2 7.2 5.0 5.3 5.5 ----------- DAILY VALUE 7.7 8.1 8.7 6.2 6.8 7.2 5.0 5.5 6.0 ------------ 0001 -0600 8.2 8.2 8.2 .7.2 7.2 7.2 4.5 4.5 4.5 -------------- 0601 -1200 8.2 8.2 8.2 7.2 7.2 7.2 4.5 4.5 4.5 MONTHLY VALUE 1201 -1800 8.2 8.2 8~2 7.2 7.5 7.7 4.5 4.8 5.0 -------------- 1801 -2400 8.2 8.2 8.2 7.2 7.4 7.7 4.5 4.5 4.5 4.0 6.6 8.7 DAILY VALUE 8.2 8.2 8.2 7.2 7.3 7.7 4.5 4.6 5.0 -----------------_._----------------------------------------------------------- 4-C-41 Table 4-C-ll.Cont..I!!!!\lii /"':~' -OCTOBER,1982 -- ------------------------~------~-.--~-----------------~.~~---~~~--------~---TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 ..24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX :ijIN MEAN MAX -------------------~~-~--------~-~--~.--------~-~---~~-------------~-~---- 0001 -0600 4.5 4.5 4.5 .5 .5 .5 0.0 0.0 0.0 ...,..---...""",....,...- 0601 -1200 4.5 4.5 4.5 .5 .5 .5 0.0 0.0 0.0 -------- 1201 -1800 4.5 4.5 4.5 1.0 1.0 1.0 0.0 ---0.0 ------.-;-- 1801 -2400 4.5 4.5 4.5 1.0 1.0 1.0 ...--..---------~ DAILY VALUE 4.5 4.5 4.5 .5 .7 1.0 0.0 ---0.0 ----...-..---0001 -0600 4.0 4.0 4.0 1.0 1.0 1.0 -..--:-------..,.-..-""!"-........- 0601 -1200 4.0 4.2 4.5 1.0 1.0 1.0 --...-..,---~-....--"---...~..... 1201 -1800 4.5 4.5 4~5 1.0 1.0 1.0 ...........-~"'""'---...,---..--- 1801 -2400 4.5 4.5 4.5 1.0 1.0 1.0 ---~--~..-.-...-.----- DAILY VALUE 4.0 4•.3 4.5 1.0 1.0 1.0 ----......---"""'-..........-------- 0001 -0600 4.0 4.2 4~5 .5 .5 .5 ----~-----....~ 0601 -1200 4.0 4.0 4.0 .5 .5 .5 ---~----....-----1201 -1800 4.5 4.5 4.5 .5 .5 .5 _......------...-...-- 1801 -2400 4.0 4.2 4.5 .5 .5 .5 --.........~......--...-~~ DAILY VALUE 4.0 4.2 4.5 .5 .5 .5 ...........----,-----"""'-~ 0001 -0600 3.0 3.3 3.5 .5 .5 .5 ---------.----"""'..... 0601 -1200 3.0 3.0 3.0 .5 .5 .5 ...........~~-----...~ 1201 -1800 3.0 3.2 ~.5 .5 .5 .5 ._---..--.-"'P ---....-"'!"'---.AIP'~- 1801 -2400 2.5 2.7 3.0'.5 .5 .5 ..........------~~---- DAILY VALUE 2.5 3.0 3.5 .5 .5 .5 ...........•""!"'---..--.--~--- 0001 -0600 1.5 1.7 2.0 .5 .5 .5 ~--...~""'"--~--------. 0601 -1200 1.5 1.5 1.5 0.0 0.0 0.0 -..------~-----1201 -1800 2.0 2.0 2.0 0.0 0.0 0.0 ~-..........--...........---~ 1801 -2400 1.5 1.7 2.0 0.0 0.0 0.0 -..---~-..-~""'"-DAILY VALUE 1.5 1.7 2.0 0.0 .1 .5 -----~------------ 0001 -0600 1.0 1.2 1.5 0.0 0.0 0.0 -------------..-......--- 0601 -1200 1.0 1.0 1.0 0.0 0.0 0.0 ---------------1lli11l!'I'. 1201 -1800 1.5 1.5 1.5 0.0 0.0 0.0 -------------------- 1801 -2400 1.5 1.5 1.5 0.0 0.0 0.0 ------------------ DAILY VALUE 1.0 1.3 1.5 0.0 0.0 0.0 -----------........... 0001 -0600 1.5 1.5 1.5 0.0 0.0 0.0 ------------------ 0601 -1200 1.0 1.3 1.5 0.0 0.0 0.0 ------------------1201 1800 1.0 1.0 1.0 0.0 0.0 0.0 \----l'------"'""-------------- 1801 -2400 1.0 1.0 1.0 0.0 o~o 0.0 ---- ---- -....."'""---------- DAILY VALUE 1.0 1.2 1.5 0.0 0.0 0.0 --------------------- 0001 -0600 .5 .8 l.O 0.0 0.0 0.0 ----------~---~""'!"-- 0601 -1200 .5 .7 1.0 0.0 0.0 0.0 -----...-MONTHLY VALUE 1201 -1800 l.0 1.0 l.0 0.0 0.0 0.0 ---------.-.-----..-.~-----...- 1801 -2400 .5 .7 1.0 0.0 0.0 0.0 --------l'_0.0 ---4.5 DAILY VALUE .5 .8 1.0 0.0 0.0 0.0 ----~-'!!"'-- -----------------------------~---"'""------~~---...---------~"--~"'""-----~-"'""-------- ~ 4~C-42 ~ F' i ,.".., c'~"'"Table 4-C-12.Thermograph data summary,summer surface water temperature (C), Curry Fishwhee1,RM 120.7.Geocode S29N04W10CBB. !'""" -JULY 1982 - --------------~--~---------~--~-~-------------~~------~------------------~-----TIME DAYS'1 - 8 DAYS 9 - 16 DAYS 17 -24,DAYS 25 -31 ,PERIOD MIN MEAN MAX MIN MEAN MAX .MIN,MEAN MAX.MIN MEAN'MAX -------------------------~-----------------_....'----------------------------------- 0001 -0600 -----.~---13.6 13.6 13 .6 10.1 10.3 10.6 9.6 9.6 9.6 0601 -1200 --------13 .1'13.3 13.6 10.1 10.1 10.1 9.6 9.6 9.6 1201,-1800 --------13 .6 13.6 13.6 10.6 10.9 11.1 9.6 9.6 9.6 1801 -2400 -------13.6 13 .8 14.1 10.6 10.8 11.1 9.6 9.6 9.6 I""'"DAILY VALUE -------13 .1 13.6 14.1 10.1 10.5 11.1 9.6 9.6 9.6 0001 -0600 --------12.6 12.9 13.1 10.6 10.6 10.6 9.1 9.1 9.1 0601 -1200 ------.-12.1 12.3 12.6 10.6 10.6 10.6 9.1 9.1 9.1......1201 ...1800 --------12.1 12.1 12.1 10.6 10.6 10.6 9.1 9.4 9.6 1801 ...2400 -------12.1 12.1 12.1 10.6 10.6 10.6 9.6 9.6 9.6 DAILY VALUE --------12.1 12.3 13.1 ·10.6 10.6 10.6 9.1 9.3 9.6 0001 -0600 -----11.6 11.6 11.6 10.6 10.6 10.6 9.6 9.9 10.1 0601 -1200 ...---------ILl 11.3-11.6 10.6 10.9 11.1 10.1 10.1 10.1 1201 -1800 ~----11.1 11.1 11.1 ·11.6 11.9 12.1 10.1 10.1 10.1 ,1801 -2400 ------10.6 10.9 11.1 12.1 12.1 12.1 10.1 10.1 10.1 DAILY VALUE -----------10.6 11.2 11.6 10.6 11.412.1 9.6 10.1 10.1 0001 ~0600 ---10.6 10.8 11.1 12.1 12.1 12.1 10.1 10.3 10.6r---0601 ~1200 --------11.1 11.1 11.1 12.1 12.3 12.6 11.1 11.1 11.1 ,1201-1800 ------ILl 11.1 11.1 13.1 13 .3 13.6 11.6 11.9 12.1 1801 ...2400 ----ILl 11.1 ILl 13 .6 13 .6 13 .6 12.1 12.1 12.1 r DAILY VALUE ------10.6 11.0 11.1 12.1 12.8 13.6 10.1 11.3 11.1 0001 -0600 --------ILl 11.1 11.1 13.6 13.6 13.6 12.1 12.1 12.1 0601 -1200 --------ILl 11.1 11.1 13.6 13.6 13.6 12.1 12.1 12.1 1201-1800 ------11.1 11.4 11.6 13.1 13 .1 13.1 11.6 11.9 12.1 1801 -2400 ---------11.6 11.6 q.6 12.6 12.8 13.1 11.6 11.6 11.6 DAILY VALUE --------ILl 11.3 11.6 12.6 13 .3-13.6 11.6 11.9 12.1 r-0001 -0600 --------11.6 11.6 11.6 12.6 12.6 12.6 11.1 11.4 11.6 0601 -1200 --------11.1 11.4 11.6 12.6 12.6 12.6 11.1 11.1 11.1 1201 -1800 ~-------11.1 11.3-11.6 12.1 12.4 12.6 10.6 10.9 11.1 1801 -2400 ------11.6 11.6 11.6 11.6 11.9 12.1 10.6 10.6 10.6.- !DAILY VALUE ----------ILl 11.5 11.6 11.6 12.4 12.6 10.6 11.0 11.6 0001 -0600 -----------ILl 11.1 11.1 '11.1 11.3-11.6 10.1 10.3-10.6 0601'-1200 ---~--~--11.1 11.1 11.1 11.1 11.1 11.1 10.1 10.1 10.1 1201 -1800 -----------ILl 11.1 11.1 10.6 10.6 10.6 10.6 10.6 10.6 1801 ...2400 14.1 14.1 14.1 10.6 10.9 11.1 10.1 10.3 10.6 10.6 10.6 10.6 DAILY VALUE 14.1 ---14.1 10.6 11.1 11.1 ·10.1 10.8 11.6 10.1 10.4 10.6.... 0001 ..0600 13.6 13-.6 13.6 10.6 10.6 10.6 9.6 9.8 10.1 ------------- 0601 -1200 13.6 13.8 14.1 10.6 10.6 10.6 9.6 9.6 9.6 MONTHLY VALUE 1201 -1800 14.1 14.1 14.1 10.6 10.6 10.6 9.6 9.6 9.6 ------------- ~1lIIIllI 1801 -2400 13 .6 13-.8 14.1 10.6 10.6 10.6 9.6 9.6 9.6 9.1 11.3 14.1 DAILY VALUE 13.6 13.8 14.1 10.6 10.6 10.6 9.6 9.6 10.1 -------------------------------------------------------------------------------- 4-C-43 Table 4-C-12.Cont.~ ,""""~ ~ -AUGUST 1982 ------------------------------------------------------------------------------- TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 .,.31 fERIOD MIN MEAN MAX.MIN MEAN'MAX.MIN MEAN MAX MIN MEAN MAX."'""------------------------------------------------------------------------------- 0001 -0600 10.1 10.1 10.1 10.9 11.1 11.4 10.4 10.410.4 11.411.411.4 0601 -1200 9.6 9.9 10.1 10.4 10.4 10.4 10.4 10.4 10.4 11.4 11.4 11.4 -1201 -1800 10.6 10.6 10.6 10.4 10.4 10.4 10.4 10.4 10.4 11.4 11.7 11.9 1801 -2400 10.6 10.6 10.6 9.9 10.2 10.4 9.9 10.1 10.4 11.4 11.6 11.9 DAILY VALUE 9.6 10.3 10.6 9.9 10.5 11.4 9.9 10.3 10.4 11.4 11.5 11.9 0001 -0600 10.6 10.6 10.6 9.9 9.9 9.9 9.4 9.4 9.4 10.9 10.9 10.9 0601 -1200 10.6 10.6 10.6 9.9 9.9 9.9 9.4 9.6 9.9 10.9 10.9 10.9 1201 -1800 11.1 11.1 11.1 9.9 10.2 10.4 .9.9 9.9 9.9 11.4 11.7 11.9 1801 -2400 11.1 11.1 11.1 9.9 9.9 9.9 9.9 .9.9 9.9 10.9 11.2 11.4 DAILY VALUE 10.6 10.811.1 9.910.0 10.4 9.4 9.7 9.9 10.9 11.2 11.9 0001 -0600 10.6 10.8 11.1 9.4 9.6 9.9 9.9 9.9 9.9 9.9 10.2 10.4 0601 -1200 10.6 10.6 10.6 9.4 9.9 10.4 9.9 9.9 9.9 9.9 9.9 9.9 1201 -,1800 11.1 11.411.6 10.4 10.7 10.9 10.4 10.4 10.4 10.4 10.7 10.9 1801 -2400 11.6 11.6 11.6 10.4 10.6 10.9 9.9 10.2 10.4 9.9 10.4 10.9 DAILY VALUE 10.6 11.1 11.6 9.4 10.2 10.9 9.9 10.1 10.4 9.9 10.3 10.9 - 0001 -0600 11.1 11.1 11.1 9.9 10.1 10.4 9.9 9.9 9.9 9.9 9.9 9.9 0601 -1200 11.1 11.3 11.6 9.9 10.1 10.4 9.9 10.4 10.9 9.9 9.9 9.9 1201 -1800 12.1 12.2 12.4 10.9 11.2 11.4 U.9 12.2 12.4 10.4 10.4 10.4 ~"""1 1801 -2400 11.9 12.1 12.4 10.4 10.7 10.9 11.4 11.9 12.4 9.9 10.2 10.4 DAILY VALUE 11.1 11.6 12.4 9.9 10.5 11.4 9.9 11.1 12.4 9.9 10.1 10.4 -0001 -0600 11.4 11.4 11.4 10.410.4 10.4 10.9 11.1.11.4 9.9 9.9 9.9 0601 -1200 11.4 11.7 11.9 10.4 10.9 11.4 10.9 11.1 11.4 9.9 9.9 9.9 1201 -1800 12.4 12.7 12.9 11.9 12.2 12.4 11.9 12.2 12.4 9.9 9.9 9.9 1801 -2400 11.9 12.2 12.4 11.9.12.2 12.4 11.912.2 12.4 9.9 9.9 9.9 ..... DAILY VALUE 11.4 12.0 12.9 10.4 11.4 12.4 10.9 11.6 12.4 9.9 9.9 9.9 0001 -0600 11".9 11.9 11.9 11.9 11.911.9 10.9 11.1 11.4 9.4 9.4 9.4 0601 -1200 11.911.911.9 11.9 11.9 11.9 10.9 11.1 11.4 9.4 9.4 9.4 1201 -1800 12.4 12.4 12.4 12.4 12.4 12.4 11.9 12.1 12.4 9.4 9.4 9.4 1801 -2400 12.4 12.4 12.4 11.9 12.112.4 11.9 11.9 11.9 8.9 9.1 9.4 DAILY VALUE 11.9 12.1 12.4 11.9 12.1 12.4 10.9 11.5 12.4 8.9 9.3 9.4 ~. 0001 -0600 11.9 11.9 11.9 11.4 11.6 11.9 11.411.411.4 8.4 8.7 8.9 0601 -1200 11.911.911.9 11.411.4 11.4 11.4 11.4 11.4 8.4 8.4 8.4 1201 -1800 11.9 11.9 11.9 11.9 12.2 12.4 11.9 11.9 11.9 8.4 8.4 8.4 ~ 1801 -2400 11.411.7 11.9 11.4 11.9 12.4 11.411.7 11.9 8.4 8.4 8.4 DAILY VALUE 11.4 11.9 11.9 11.4 11.8 12.4 .11.4 11.6 11.9 8.4 8.5 8.9 0001 -0600 11.4 11.4 11.4 10.911.211.4 11.411.411.4 -------------"""'l 0601 -1200 11.411.411.4 10.9 11.1 11.4 11 ~4 11.4 11.4 MONTHLY VALUE 1201 -1800 11.9 11.9 11.9 11.4 11.7 11.9 11.4 11.7 11.9 ------------ 1801 -2400 11.4 11.6 11.9 10.9 11.1 11.4 11.4 11.7 11.9 8.4 10.9 12.9 DAILY VALUE 11.4 11.6 11.9 10.9 11.3 11.9 11.4 11.6 11.9 ------------------------------------------~------------------------------------- l~·-c--44 Table 4-C-12.Cont. ,~ -SEPTEMBER 1982 - -----~--_._-------~-----------------------------------------~-----~-----------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31-PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ---------------.--------~----------------------------------------------------- -0001-0600 8.4 8.4 8.4 8.1 8.1 8.1 '7.1 7.4 7.6 4.5 4.5 4.5 0601 -1200 8.4 8.6 8.9 8.1 8.1 8.1 7.1 7.1 7.1 4.5 4.5 4.5 1201 -1800 8.9 8.9 8.9 8.1 8.1 8.1 \7.5 7.5 7.5 5.0 5~0 5.0 1801 ~2400 8.4 8.7 8.9 8.1 8.1 8.1 7.5 7.5 7.5 4.5 4.5 4.5 r-'DAILYV,ALUE 8.4 8.6 8.9 8.1 8.1 8.1 7.1 7.4 7.6 4.5 4.6 5.0 0001 -0600 8.4 8.4 8.4 7.6 7.6 7.6 7:0 7.2 7.5 4.5 4.5 4.5 0601 -1200 '8.4 8.4 8.4 7.6 7.6 7.6 6.5 6.5 6.5 4.5 4.8 5.0-1201-1800 8.4 8.6 8.9 7.6 7.6 7.6 "6.5 6.5 6.5 5.0 5.3 5.5 1801-2400 8.4 8.6 8.9 7.6 7.6 7.6 6.5 6.5 6.5 5.5 5.5 5.5 ,DAILY VALUE 8.4 8.5 8.9 7.6 7.6 7.6 6.5 6.7 7.5 4.5 5.0 5.5 .-8.40001-0600 8.4 8.4 7.1 7.1 7.1 6.5 6.5 6.5 5.5 5.5 5.5 0601 -1200 8.4 8.4 8.4 7.1 7.1 7.1 6.5 6.7 7.0 5.5 5.5 5.5 1201 -1800 8.6 8.6 8.6 '7.1 7.1 7.1 6.5 6.8 7.0 5.5 5.5 5.5,....1801 -2400 8.1 8.1 8.1'6.6 6.8 7.1 6.5 6.5 6.5 5.0 5.3 5.5 DAILY VALUE 8.1 8.4 8.6 6.6 7.0 7.1 6.5 6.6 7.0 5.0 5.5 5.5 0001 -0600 8.1 8.1 8.1 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.7 5.0 1"""',-0601 -1200 8.1 8.1 8.1 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 1201 -1800 8.1 8.1 8.1 6.1 6.4 6.6 6.5 6.5 6.5 4.5 4.7 5.0 1801 -2400 8.1 8.1 8.1 6.1 6.3 6.6 6.5 6.5 6.5 4.5 4.5 4.5 DAILY VALUE 8.1 8.1 8.1 6.1 6.2 6.6 6.5 6.5 6.5 4.5 4.6 5.0 Oq01 ...0600 7.6 7.6 7.6 6.1 ,6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 0601 -1200 7.6 7.6 7.6 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 1201 -1800 8.1 8.1 8~1 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 ,',,1801 -2400 7.6 7.9 8.1 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 DAILY VALUE 7.6 7.8 8.1 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 0001 -0600 7.6 7.6 7.6 6.1 6.1 6.1 6.5 6.5 6.5 4.5 4.5 4.5 0601 -1200 7.6 7.6 7.6 '6.6 6.6 6.6 6.5 6.5 6.5 4.5 4.5 4.5 1201 -1800 8.1 8.1 8.1 6.6 6.6 6.6 6.5 6.5 6.5 5.0 5.0 5.0 1801 -2400 8.1 8.1 8.1 6.6 6.6 6.6 6.0 6.2 6.5 ---------- F""DAILY VALUE'7.6 7.8 8.1 6.1 6.5 6.6 6.0 6.4 6.5 4.5 ----5.0 0001 -0600 8.1 8.1 8.1 6.6 6.6 6.6 6.0 6.0 6.0 ------- ---- 0601-1200 8.1 8.1 8.1 6.6 6.6 6.6 5.5 5.8 6.0 ------------ 1201 -1800 8.6 8.8 '9.1 7.1 7.1 7.1 6.0 6.0 6.0 ----------- 1801 -2400 8.6 8.9 9.1 7.1 7.3 7.6 5.0 5.3 5.5 ------- ---- DAILY VALUE 8.1 8.5 9.1 6.6 6.9 7.6 5.0 5.8 6.0 -------- ---- 0001 -0600 8.6 8.6 8.6 7.6 7.6 7.6 5.0 5.0 5.0 -------------- 0601 -1200 8.6 8.6 '8.6 7.6 7.6 7.6 5'.0 5.0 5.0 MONTHLY VALUE 1201 -1800 8.6 8.6 8.6 7.6 7.6 7.6 5.0 5.0 5.0 --------------1801 ...2400 8.1 8.4 8.6 7.6 7.6 7.6 4.5 4.7 5.0 4.5 6.8 9.1 DAILY VALUE 8.1 8.6 8.6 7.6 7.6 7.6 4.5 4.9 5.0 --------------------------------------------------------------------~-----------..... 4-C-45 Table 4-C-13.Thermograph data summary.summer surface water temperature (C). Slough 8A-Area of R&M Stage Recorder.RM 126.0.Geocode S30N03W30BCA•. -JULY 1982 - --------------~--~-------------------------------------------------------------- .~. ""'" TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX ---------~---------------------------------------------------------------------- 0001 0600 -------- 0601 1200 1201 1800 --1801 2400 ---- DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 --..~ DAILY VALUE 0001 0600 0601 1200 -. 1201 1800 ---- 1801 2400 - DAILY VALUE 0001 0600 0601 1200 1201 1800 8.8 9..0 9.3 ~.-1801 2400 6.8 7.3 7.8 DAILY VALUE 6.8 9.3 0001 0600 ----6~3 6.5 6.8 ~ 0601 1200 6.3 6.8 7.3 1201 1800 _..7.3 7~6 7.8 1801 2400 6.3 6.8 T.3 DAILY VALUE 6.3 6.9 7.8 0001 0600 6.3 6.3 6.3 0601 1200 6.3 6.5 6.8 1201 1800 6.8 6.8 6.8 1801 2400 6.3 6.5 6.8 DAILY VALUE ---6.3 6.5 6.8 ".,.. 0001 -0600 5.8 6.0 6.3 0601 1200 5.8 6.8 7.8 1201 1800 7.8 8.1 8.3 1801 2400 5.8 6.6 7.3 ""'" DAILY VALUE 5.8 6.9 8.3 0001 0600 --------------0601 1200 ---MONTHLY VALUE 1201 1800 ------------- 1801 2400 5.8 -_.-9.3 DAILY VALUE ,;,.,.---~- ------------------------------------------------------------------------~------- 4-C-46 Tab Ie 4-C-13.Cont. -AUGUST 1982 - -------------------------------------------------------------~--------~--------- TIME DAYS 1 ...8·DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 4.8 5.0 5.3 6.8 6.8 6.8 7.3 7.6 7.8 8.3 8.6 8.8 0601 -1200 5.3 6.5 7.8 6.8 7.1 7.8 7.3 7.5 7.8 8.3 9.0 9.8 1201 -1800 8.8 9.3 9.8 8.3 8.6 8.8 8.3 9.0 9.3 11.3 11.8 12.3 1801 -2400 6.3 7.0 7.8 7.3 7.5 7.8 7.3 8.0 8.8 8.8 9.5 10.3 DAILY VALUE 4.8 6.9 9.8 6.8 7.5 8.8 7.3 8.0 9.3 8.3 9.7 12.3 0001 -0600 4.8 5.0 5.3 6.8 6.8 6.8 6.8 6.8 6.8 8.3 8.3 8.3 0601 ..1200 5.3 6.6 8.3 6.8 7.1 7.8 6.8 7.6 8.3 8.3 9.5 10.8 1201 ...1800 9.8 10.0 10.3 7.8 7.8 7.8 8.8 8.8 8.8 10.8 12.0 12.8 1801 ...2400 6.3 7.5 8.8 6.8 7.0 7.3 6.3 7.3 8.3 8.8 9.6 10.3 DAILY VALUE 4.8 7.3 10.3 6.8 7.2 7.8 6.3 7.6 8.8 8.3 9.8 12.8 r- 0001 -0600 5.3 5.5 5.8 6.3 6.5 6.8 5.8 5.8 5.8 6.3 7.0 7.8 0601 -1200 5.3 7.0 8.8 6.3 8.1 9.8 6.3 7.5 8.8 6.3 7.8 9.8 1201 -1800 9.8 10.3 10.8 11.3 11.8 12.3 9.8 10.1 10.3 10.3 11.6 12.3 1801 -2400 7.3 7.8 8.3 6.8 8.3 10.3 6.8 7.8 8.8 8.3 9.1 9.8 DAlLY VALUE 5.3 7.6 10.8 6.3 8.7 12.3 5.8 7.8 10.3 6.3 8.9 12.3 ~,~-'1~,0001 -0600 5.8 ·6.0'6.3 5.3 5.8 6.3 5.8 6.0 6.3 6.8 7.3 7.8 0601 ..1200 6.3 7.6 9.3 5.8 7.6 9.8 6.3 7.8 9.3 6.8 7.6 8.8 1201 -1800 10.8 11.0 11.3 11.8 12.3 12.8 11.8 12.6 13.3 9.8 10.3 10.8 1801 -2400 7.3 8.0 8.8 7.3 8.1 9.3 7.3 9.0 10.8 8.3 9.0 9.8 DAILY VALUE 5.8 8.1 11.3 5.3 8.5 12.8 5.8 8.8 13.3 6.8 8.5 10.8 0001 -0600 6.3 6.5 6.8 6.8 7.0 7.3 6.3 6.5 6.8 7.8 8.0 8.3 0601 -1200 6.8 8.1 9.8 6.8 8.6 10.8 6.3 8.1 10.3 7.8 8.1 8.8....1201 -1800 10.3 10.8 11.3 12.3 12.813.'>12.3 12.8 13.3 9.3 9.3 9.3 1801 -2400 6.8 7.8 8.8 8.3 9.3 10.3 7.3 9.0 10.8 7.8 8.3 8.8 DAILY VALUE 6.3 8.3 11.3 6.8 9.4 13.3 6.3 9.1 13 .3 7.8 8.4 9.3 0001 -0600 6.3 6.5 6.8 8.3 8.3 8.3 5.8 6.3 6.8 7.8 7.8 7.8 0601 -1200 6.8 8.3 9.8 7.8 8.0 8.3 6.3 8.1 10.3 7.8 7.8 7.8 1201 -1800 10.8 11.6 12.3 8.3 8.6 8.8 11.8 12.6 13.3 7.8 8.1 8.3 F'"1801 -2400 7.3 8.5 9.8 6.8 7.5 8.3 ---------7.3 7.5 7.8 DAILY VALUE 6.3 8.7 12.3 6.8 8.1 8.8 5.8 9.0 13.3 7.3 7.8 8.3 0001 -0600 6.3 6.5 6.8 6.8 6.8 6.8 ----------6.8 7.0 7.3 F"0601 -1200 6.8 8.0 9.3 6.8 7.6 8.8 ----------6.8 7.3 7.8 1201 -1800 8.3 9.3 10.3 10.8 11.5 12.3 11.8 ---11.8 8.3 8.6 8.8 1801 -2400 6.8 7.3 7.8 7.8 8.5 9.3 8.8 9.5 10.3 7.3 7.5 7.8 DAILY VALUE 6.3 7 .8 10.3 6.8 8.6 12.3 8.8 ---11.8 6.8 7.6 8.8- 0001 -0600 5.8 6.0 6.3 7.3 7.3 7.3 8.3 8.3 8.3 ------------- 0601 -1200 6.3 8.1 9.8 7.3 8.8 10.8 8.3 9.1 10.3 MONTHLY VALUE .1201 -1800 9.8 10.8 11.3 11.3 12.1 12.8 11.3 11.6 11.8 ---------------1801 -2400 7.3 7.8 8.8 8.3 9.0 9.8 9.3 10.0 10.8 4.8 8.4 13.3 DAILY VALUE 5.8 8.2 11.3 7.3 9.3 12.8 8.3 9.811.8 ....-------------------------~------------------------------------------------------ 4-c-47 Table 4~C-13.Cant.1'!!'1<\ ~ -SEPTEMBER 1982 --------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX.MIN MEAN MAX.MIN-MEAN MAX MIN MEAN MAX.--------------------------------------------------------------------------------- 0001 -0600 6.8 7.1 7.3 6.3 6.3 6.3 5.3 5.3 5.3 3.3 3.6 3.8 0601 -1200 7.3 8.0 8.8 6.3 6.5 6.8 5.3 5.3 5.3 3.3 3.5 3.8 1201 -1800 8.8 9.1 9.3 7.8 7.8 7.8 5.3 5.3 5.3 4.3 4.6 4.8 1801 -2400 6.8 7.5 8.3 6.3 6.8 7.3 5.3 5.3 5.3 4!3 4.3 4.3 DAILY VALUE 6.8 7.9 9.3 6.3 6.8 7.8 5.3 5.3 5.3 3.3 4.0 4.8 ~, 0001 -0600 6.3 6.5 6.8 5.8 6.1 6.3 4.8 5.1 5.3 4.3 4.3 4.3 0601 -1200 6.3 6.8 7.3 5.8 6.5 7.3 5.3 5.5 5.8 4.3 4.3 4.3 1201 -1800 8.3 8•.8 9.3 7.8 7.8 7.8 5.8 5.8 5.8 4.8 4.8 4.8 1801 -2400 7.3 7.5 7.8 6.3 6.5 6.8 5.8 5.8.5.8 4.3 4.5 4.8 DAILY VALUE 6.3 7.4 9.3 5.8 6.7 7.8 4.8 5.5 5.8 4.3 4.5 4.8 0001 -0600 6.8 7.0 7.3 5.8 5.8 5.8 5.3 5.5 5.8 4.3 4.3 4.3 4.3 ~0601 -1200 6.8 6.8 6.8 5.8 6.0 6.3 5.3 5.5 5.8 4.3 4.3 1201 -1800 7.3 7.5 7.8 6.3 6.6 6.8 5.8 5.8 5.8 4.8 4.8 4.8 1801 ...2400 6.8 6.8 6.8 5.3 5.8 6.3 5.8 5.8 5.8 3.8 4.3 4.8 DAILY VALUE 6.8 7.0 7.8 5.3 6.0 6.8 5.3 5.6 5.8 3.8 4.4 4.8 ~ 0001 -0600 5.8 6.1 6.3 4.8 4.8 4.8 5.3 5.3 5.3 2.8 3.3 3.8 0601 -1200 5.8 6.1 6.8 4.8 5.0 5.3 5.3 5.5 5.8 2.8 3.0 3.3 1201 -1800 7.3 7.8 8.3 6.8 6.8 6.8 5.8 5.8 5.8 3.8 3.8 3.8 ~-1801 -2400 6.3 6.5 6.8 5.3 5.6 5.8 ----------3.8 3.8 3.8 DAILY VALUE 5.8 6.6 -8.3 4.8 5.5 6.8 5.3 ---5.8 2.8 3.5 3.8 0001 -0600 5.8 6.1 6.3 5.3 5.3 5.3 -----------3.8 3.8 3.8 ~ 0601 -1200 5.8 6.5 7.3 5.3 5.3 5.3 5.8 ---5.8 3.8 3.8 3.8 1201 -1800 7.3 7.6 7.8 5.8 6.0 6.3 5.8 5.8 5.8 4.8 4.8 4.8 1801 -2400 6.3 6.6 6.8 5.8 5.8 5.8 5.8 5.8 5.8 4.8 4.8 4.8 ~, DAILY VALUE 5.8 6.7 7.8 5.3 5.6 6.3 5.8 ---5.8 3.8 4.3 4.8 0001 -060-0 6.3 6.3 6.3 5.8 5.8 5.8 5.3 5.3 5.3 4.3 4.3 4.3 0601 -1200 6.3 6.8 7.3 5.8 5.8 5.8 5.3 5.3 5.3 4.3 4.3 4.3 ~\ 1201 -1800 7.3 7.3 7.3 6.3 6.3 6.3 5.8 5.8 5.8 5.2 5.2 5.2 1801 -2400 6.3 6.6 ,6.8 5.8 6.0 6.3 4.8 5.0 5.3 4.7 4.7 4.7 DAILY VALUE 6.3 6.8 7.3 5.8 6.0 6.3 4'.8 5.3 5.8 4.3 4.7 5.2 ~, 0001 -0600 6.3 6.3 6.3 5.8 5.8 5.8 3.8 4.3 4.8 --------- 0601 -1200 6.8 7.1 7.8 5.8 6.3 6.8 3.8 3.8 3.8 -------- 1201 -1800 8.3 8.6 8.8 7.3 7.3 7.3 4.3 5.0 5.3 ----------- 1801 -2400 6.8 7.3 7.8 6.8 6.8 6.8 3.8 4.1 4.8 ~--------- DAILY VALUE 6.3 7.3 8.8 5.8 6.5 7.3 3.8 4.3 5.3 ----------- 0001 -0600 6.8 6.8 6.8 5.8 6.1 6.3 2.8 3.3 3.8 -------------~ 0601 -1200 6.8 7.1 7.8 5.8 6.0 6.3 2.8 3.1 3.8 MONTHLY VALUE 1201 -1800 7.8 7.8 7.8 6.3 6.5 6.8 4.3 4.6 4.8 --------------- 1801 -2400 6.8 7.0 7.3 5.8 5.8 5.8 3.8 4.1 4.3 2.8 5.8 9.3 DAILY VALUE 6.8 7.2 7.8 5.8 6.1 6.8 2.8 3.8 4.8 -------------------------------------------------------------------------------- 4-C-48 r- ,.;f.......~Table 4-C-13.Cont. I"'" -OCTOBER 1982 ---------------------------------------------------------------------------------.-TIME DAYS 1 -8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ------------------------------------------------------------------------------- 0001 -0600 4.2 4.4 4.7 1.2 1.5 1.7 .7 .7 .7 -------- 0601 -1200 4.2 4.2 4.2 1.7 2.2 2.7 .7 1.2 1.7 ------------ 1201 -1800 4.2 4.5 4.7 3.2 3.2 3.2 1.7 2.0 2.2 ---------- 1801 -2400 3.7 3.9 4.2 2.2 2.4 2.7 .2 .7 1.2 --- --- ---- DAILY VALUE 3.7 4.2 4.7 1.2 2.3 3.2 .2 1.2 2.2 ---------- 0001 -0600 3.7 3.7 3.7 2.2 2.2 2.2 .2 .2 .2 -------- I"'"0601 -1200 3.7 3.9 4.2 2.2 2.4 2.7 .2 .4 .7 -------- 1201 -1800 4.2 4.5 4.7 2.7 2.7 2.7 .7 .7 .7 ---------- 1801 -2400 3.7 3.7 3.7 1.7 2.0 2.2 .7 .7 .7 ----------- DAILY VALUE 3.7 3.9 4.7 1.7 2.3 2.7 .2 .5 .7 ------------ I""" 0001 -0600 3.2 3.5 3.7 1.7 1.7 1.7 .7 .7 .7 ---------- 0601 -1200 3.2 3.2 3.2 1.2 1.5 1.7 .2 .2 .2 ---------- 1201 -1800 3.7 4.0 4.2 1.2 1.9 .2.2 .7 .7 .7 ----------- 1801 -2400 3.2 .3.4 3.7 .7 1.2 1.7 .7 ,.7 .7 -------- DAILY VALUE 3.2 3.5 4.2 .7 1.6 2.2 .2 .6 .7 --------- 0001 -0600 2.2 2.5 2.7 .7 .7 .7 .7 .7 .7 --_.--------~"'~"\0601 -1200 2.2 2.4 2.7 .7 1.2 1.7 .7 .7 .7 --------- 1201 -1800 3.2 3.2 3.2 2.2 2.2 2.2 .7 1.0 1.2 ------.----- 1801 -2400 2.2 2.4 2.7 1.7 2.0 2.2 .2 .2 .2 --------- DAILY VALUE 2.2 2.6 3.2 .7 1.5 2.2 .2 .7 1.2 ---------- 0001 -0600 2.2 2.2 2.2 .7 1.2 1.7 ---------- --- -------- 0601 -1200 1.7 2.0 2.2 1.2 1.2 1.2 ------------------- ~1201 -1800 2.7 2.7 2.7 1.2 1.4 1.7 ------- --- ------------ 1801 -2400 1.7 1.9 2~2 1.2 1.5 1.7 --------------------- DAILY VALUE 1.7 2.2 2.7 .7 1.3 1.7 -------------------- 0001 -0600 1.2 1.4 1.7 1.2 1.2 1.2 ---------------------- 0601 -1200 1.2 1.7 2.2 .7 1.0 1.7 ----------------------- 1201 -1800 2.7 2.7 2.7 1.7 2.0 2.2 -------------------- "-1801 -2400 2.2 2.2 2.2 .7 1.0 1.2 ---------------------- DAILY VALUE 1.2 2.0 2.7 .7 1.3 2.2 -------------------- 0001 -0600 2.2 2.2 2.2 .2 .2 .2 ---------------------- I"""0601 -1200 1.7 2.0 2.2 .2 .2 .2 ----------------- ---- 1201 -1800 2.2 2.5 2.7 .7 .7 .7 ---------------------- 1801 -2400 2.2 2.4 2.7 .2 .4 .7 ------------------------ DAILY VALUE 1.7 2.3 2.7 .2 .4 .7 -------------------- 0001 -0600 107 1.9 2.2 .7 .7 .7 ----------------------- 0601 -1200 1.7 2.2 2.7 .7 .7 .7 ------------MONTHLY VALUE 1201 -1800 2.7 3.0 3.2 .7 .7 .7 -----------------------,.....1801 2400 1.2 1.7 2.2 .7 .7 .7 .2 4.7I------------- ---- DAlLY VALUE 1.2 2.2 3.2 .7 .7 .7 ---------- -------------------------------------------------------------------------------- 4-C-49 Table 4-C-14.Thermograph data summary.summer surface water temperature (e), LRX 29.RM 126.1.Geocode 53 ON03W19DCA..A1'. -JULY 1982 - -----------------------------------~--------------------------------------------TIME DAY 5 1 -8 DAYS 9 - 16 DAYS 17 ...24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -----------------------------------~-------------------------------------------- 0001 -0600 -------..-----10.2 10.2 10.2 10.2 10.2 10.2 0601 -1200 ------------10.2 10.7 11.2 10.2 10.2 10.2 1201 -1800 ------...--15.7 ----15.7 12.2 12.2 12.2 9.7 9.7 9.7 1801 -2400 -------14.2 14.7 15.2 11.2 11.411.7 9.7 9.7 9.7 DAILY VALUE ------14.2 ---15.7 10.2 11.1 12.2 9.7 9.9 10.2 0001 -0600 ----13.2 13.4 13.7 10.7 10.9 11.2 9.7 9.7 9.7 0601 -1200 -----12.7 12.7 12.7 10.7 11.0 11.2 9.7 9.7 9.7 1201 -1800 -----12.7 12.7 12.7 .11.2 11.5 11.7 10.2 10.9 11.2 1801 -2400 -------12.2 12.2 12.2 11.2 11.4 11.7 10.7 10.7 10.7 DAILY VALUE ---------12.2 12.7 13.7 10.7 11.2 11.7 9.7 10.2 11.2 0001 -0600 ------11.7 11.9 12.2 10.7 10.7 10.7 10.7 10.7 10.7 0601 -1200 ----11.7 11.7 11.7 11.2 11.9 12.7 11.7 ---11.7 1201 -1800 -----12.2 12.2 12.2 13 .2 13.5 13.7 ------------ 1801 -2400 ---~11.2 11.5 11.7 12.2 12.7 13 .2 ------- DAILY VALUE ----11.2 11.8 12.2 10.7 12.2 13.7 10.7 ----11.7 0001 -0600 --_.......11.2 11.2 11.2 12.2 12.2 12.2 -~----- 0601 -1200 ...---11.2 11.4 11.7 12.2 13.0 13.7 ----- 1201 -1800 -----11 ~7 11.7 11.7 14.2 14.7 15.2 --~---- 1801 -2400 ------11.211.411.7 13.7 14.2 14.7 ---_.--- DAILY VALUE ------11.2 11.411.7 ·12.2 13.5 15.2 -------'-- 0001 -0600 ---'-------11.2 11.2 11.2 13.7 13.7 13.7 --------- 0601 -1200 ----11.2 11.4 11.7 13.7 13.7 13.7 ----------- 1201 -1800 -----12.2 12.2 12.2 13.2 13.5 13.7 ------'------1801 -2400 ------11.7 12.0 12.2 12.7 13 .0 13.2 12.2 12.2 12.2 DAILY VALUE ---,---11.2 11.7 12.2 12.7 13.5 13.7 12.2 --12.2 0001 -0600 ------11.7 11.7 11.7 12.2 12.2 12.2 11.7 11.7 11.7 0601 -1200 -----11.7 11.7 11.7 12.2 12.2 12.2 11.7 11.7 11.7 1201 -1800 --------11.7 12.0 12.2 12.7 12.7 12.7 11.2 11.5 11.7 1801 -2400 ------11.7 11.9 12.2 11.7 12.012.2 11.2 11.2 11.2 DAILY VALUE -------11.7 11.8 12.2 11.7 12.3 12.7 11.2 11.5 11.7 0001 -0600 ------11.2 11.2 11.2 11.7 11.7 11.7 10.7 10.7 10.7 0601 -1200 ------11.2 11.4 11.7 11.2 11.2 11.2 10.7 n.o 11.2 1201 -1800 ----------12.2 12.2 12.2 11.2 11.2 11.2 11.2 11.2 11.2 1801 -2400 -------11.2 11.4 11.7 10.2 10.5 10.7 10.7 10.9 11.2 DAILY VALUE --------11.2 11.5 12.2 10.2 11.211.7 10.7 10.9 11.2 0001 -0600 -------10.7 10.9 n.2 10.2 10.2 10.2 ---------- 0601 -1200 -----10.7 11.0 11.2 10.2 10.2 10.2 MONTHLY VALUE 1201 -1800 -------11.7 11.7 11.7 10.2 10.2 10.2 ------------ 1801 -2400 ---------10.7 10.9 11.2 10.2 10.2 10.2 9.7 ---15.7 DAILY VALUE ---------10.7 11.1 11.7 10.2 10.2 10.2 4--C-SO - - - - I""" Table 4-C".14.Cont. ~, ~ -AUGUST 1982 - ----------------------------------------------------------------------------- ~TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX----_.._-------------------------------------------- 0001 -0600 10.2 10.2 10.2 11.1 11.3 11.6 10.6 10.6 10.6 11.6 11.6 11.6 0601 -1200 10.2 10.7 11.2 10.6 10.8 11.1 10.6 10.6 10.6 11.6 11.6 11.6 1201 ...1800 11.2 11.5 11.7 11.1 11.1 11.1 10.6 10.6 10.6 12.1 12.1 12.1 1801 -2400 10.2 10.7 11.2 10.6 10.6 10.6 10.1 10.4 10.6 11.6 11.812.1 DAlLY VALUE 10.2 10.8 11.7 10.6 10.9 11.6 10.1 10.6 10.6 11.6 11.812.1 0001 -0600 10.2 10.2 10.2 10.1 10.1 10.1 9.6 9.6 9.6 11.1 11.1 11.1 0601 -1200 10.2 10.7 11.2 10.1 10.1 10.1 9.6 9.9 10.1 11.1 11.3 11.6 1201-1800 12.2 12.2 12.2 10.6 10.6 10.6 10.6 10.6 10.6 12.1 12.1 12.1 1801 -2400 11.2 11.7 12.2 10.1 10.3 10.6 10.1 10.4 10.6 11.1 11.4 12.1 DAILY VALUE 10.2 11.2 12.2 10.1 10.3 10.6 9.6 10.1 10.6 11.1 11.5 12.1 0001 -0600 10.2 10.4 10.7 10.1 10.1 10.1 10.1 10.1 10.1 10.1 10.3 10.6 0601 -1200 10.2 11.2 12.2 10.1 10.6 11.1 10.1 10.3 10.6 9.6 9.9 10.6 1201 -1800 12.7 13.0 13.2 11.6 11.812.1 11.1 11.1 11.1 11.1 11.4 1L6 I""'"1801 -2400 11.7 11.9 12.2 10.6 11.1 11.6 10.6 10.8 11.1 10.1 10.6 11..1 DAlLY VALUE 10.2 11.6 13.2 10.1 10.9 12.1 10.1 10.6 11.1 9.6 10.6 11.6 0001.-0600 11.2 11.2 11.2 10.1 10.3 10.6 10.1 10.1 10.1 10.1 10.1 10.1 ~"0601 -·1200 11.2 12.0 12.7 10.1 10.3 10.6 10.1 10.8 11~6 10.1 10.3 10.6 1201 -1800 13.2 13.8 14.6 11.6 11.9 12.1 12.6 12.9 13.1 10.6 10.9 11.1 1801 -2400 1Z.1 12.6 13 .1 11.1 11.4 11.6 11.6 12.1 12.6 10.1 10.6 11.1 DAlLY VALUE 11.2 12.4 14.6 10.1 11.0 12.1 10.1 11.5 13.1 10.1 10.5 11.1 0001 -0600 11.6 11.8 12.1 10.6 10.6 10.6 11.1 11.1 11.1 10.1 10.1 10.1 0601 -1200 11.6 12.1 12.6 10.6 11.1 11.6 11.1 11.3 11.6 10.1 10.1 10.1 ~1201 -1800 13 .1 13.4 ]3.6 12.6 12.9 13.1 12.6 12.9 13.1 10.1 10.1 10.1 1801 -2400 12.1 12.6 13 .1 12.6 12.8 13.1 11.6 12.1 12.6 10.1 10.1 10.1 DAlLY VALUE 11.612.5 13.6 10.6 11.813.1 11.1 11.813.1 10.1 10.1 10.1 ~0001 -0600 11.6 11.9 12.1 12.1 12.1 12.1 11.1 11.1 11.1 9.6 9.6 9.6 0601 -1200 11.6 12.1 12.6 12.1 12.1 12.1 11.1 11.3 11.6 9.6 9.6 9.6 1201 -1800 12.6 13.3 13.6 12.6 12.6 12.6 12.1 12.4 12.6 9.6 9.6 9.6 1801 -2400 12.1 12.6 13.1 12.1 12.3 12.6 12.1 12.3 12.6 9.1 9.4 9.6 DAlLY VALUE 11.6 12.5 13.6 12.1 12.3 12.6 11.1 11.8 12.6 9.1 9.6 9.6 0001 -0600 11.6 11.812.1 11.6 11.9 12.1 11.6 11.6 11.6 8.6 8.9 9.1 0601 -1200 11.6 11.8 12.1 11.6 11.812.1 11.6 11.8 12.1 8.6 8.6 8.6 1201 -1800 12.1 12.3 12.6 12.6 12.9 13.1 12.1 12.4 12.6 9.1 9.1 9.1 1801 -2400 11.6 11.9 12.1 11.6 12.1 12.6 11.6 11.9 12.1 8.6 8.9 9.1 DAlLY VALUE 11.6 11.9 12.6 11.6 12.2 13.1 11.6 11.9 12.6 8.6 8.9 9.1-0001 -0600 11.1 11.4 11.6 11.1 11.4 11.6 11.6 11.6 11.6 -------------- 0601 -1200 11.1 11.6 12.1 11.1 11.411.6 11.6 11.6 11.6 MONTHLY VALUE 1201 -1800 12.6 12.6 12.6 12.1 12.3 12.6 12.1 12.4 12.6 ------------- 1801 -2400 11.6 11.9 12.1 11.1 11.3 11.6 11.6 12.1 12.6 8.6 11.3 14.6 DAILY VALUE 11.1 11.9 12.6 11.1 11.6 12.6 11.6 11.9 12.6 -------------------------------------------------------------~------------------ 4-C-51 Table 4-C-14.Cont. -OCTOBER 1982 - ---.-~-~--------------------~-------~------------------------------.------------- ______~M M _ TIME PERIOD 0001 0601 1201 DAYS 1 - 8 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX. .-"--- DAYS 17 -24 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX. 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8'-- 0600 1200 1800 1801 2400 DAILY VALUE - 0001 0601 1201 1801 DAILY 0600 1200 1800 2400 VALUE 0001 -0600 0601.-1200 1201 -1800 1801·-2400 DAlLY VALUE 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE 0600 1200 1800.- 0001 0601 1201 1801 2400 DAILY VALUE 0600 1200 1800 0001 0601 1201 1801 2400 DAlLY VALUE - 0001·-0600 0601 1200 1201 1800 1801 2400 DAlLY VALUE 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE MONTHLY VALUE 3.8 ----3.8 4-C-53 Table 4-C-15.TheI'lI!ograph data summary,summer surface water temperature (.C), Slough 9-Area of R&M Stage Recorder,RM 129.2.Geocode S30N03W16ACB. - ...-JULY 1982 - --------------------------------~---.-----------~----~-----------------.-------TIME PERIOD DAYS 1 - 8 MIN MEAN MU DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX. DAYS 25 -31 MIN MEAN MAX ---------------------------------~---------~-------------------------------- 0001 -0600 ---- ---- ---- 0601 -1200 -------- 1201 -1800 ----- 1801 -2400 ---- DAILY VALUE ---- .-...-.-~---- ---.. 0001 -0600 0601 -1200 ---- 1201 -1800 ------- 1801 -2400 - - DAILY VALUE -------- ----~------ ----~---~ --,--....,.--.-- -... 12.5 12.5 12.5 12.0 12.2 12.5 12.0 12.5 MONTHLY VALUE ---- --------10.0 10.0 10.0 ---.------10.0 10.0 10.0 ------------10.5 10.5 10.5 --------10.,0 10.2 10.5 10.0 10.2 10.5 .-.----...--..-..-..--- .10.0 ~--12.5 -------~~11.5 11.5 -11.5 - ----.---lL5 11.7 12.0 - -----------11.5 11.8 12.0 -------------11.011.2 11.5 ---...--------11.0 11.5 12.0 -----------10.5 10.7 11.0 -------10.5 10.5 10.5 ------------10.5 10.5 10.5 ~--------10.5 10.5 10.5 ----------10.5 10.5 11.0 ---~~~----.- ~---~--......-.~- ~--...-------- ------....----------~--- --~ 0001 -0600 ------ 0601 -1200 --~- 1201 -1800 ---- 1801 -2400 ---- DAILY VALUE --- 0001 -0600 ---- 0601 -1200 --- 1201 -1800 --- 1801 -2400 ------ DAILY VALUE ---.-- 0001 -0600 0601 -1200 ----- 1201 -1800 --- 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 -------- DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 ---- 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE -----------------------------------------------------------------------~-------- 4--C-54 - "'-Table 4-C-15.Cont. piiIlo. -AUGUST 1982 - ------------------------------------------------------------~-------------------TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX M1N MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- ......0001 -0600 9.5 9.7 10.0 8.0 8.5 9.0 8.0 8.5 9.0 8.5 9.0 9.5 0601 - 1200 9.5 9.7 io'.o 7.5 7.7 8.0 7.5 7.5 7.5 8.0 8.0 8.0 1201 -1800 10.5 10.8 11.0 9.0 9.5 10.0 8.0 8.7 9.5 8.5 9.3 10.0 ..-1801 -2400 10.0 10.2 10.5 9.0 9.5 10.0 8.5 9.2 9.5 9.0 9.8 10.5 DAILY VALUE 9.5 10.1 11.0 7.5 8.8 10.0 7.5 8.5 9.5 8.0 9.0 10.5 0001 -0600 9.0 9.3 9.5 8.0 8.2 8.5 7.5 7.7 8.0 7.5 8.0 8.5 0601 - 1200 9.0 9.7 10.5 7.5 7.7 8.0 7.0 7.2 7.5 7.5 7.7 8.0 1201 - 1800 11.5 11.812.0 9.0 9.3 9.5 8.0 8.7 9.0 9.0 10.3 11.5 1801 -2400 9.5 10.7 11.5 8.5 9.0 9.5 8.0 8.7 9.0 9.5 10.7 11.5 DAILY VALUE 9.0 10.4 12.0 7.5 8.5 9.5 7.0 8.0 9.0 7.5 9.2 11.5 0001 -0600 8.0 8.5 9.0 7.5 7.7 8.0 6.5 6.8 7.5 6.5 7.3 8.0 0601 -1200 8.0 9.2 10.5 7.0 7.7 8.5 6.0 6.5 7.0 6.0 6.0 6.0 1201 - 1800 12.0 12.3 12.5 10.0 10.8 11.5 8.0 9.0 10.0 7.5 9.2 11.0 1801 -2400 9.5 10.7 12.0 8.5 9.8 11.0 8.5 9.3 10.0 9.0 10.0 11.0 DAILY.VALUE 8.0 10.2 12.5 7.0 9.0 11.5 6.0 7.9 10.0 6.0 8.1 11.0 ~"-,~0001 -0600 7.5 8.2 9.0'6.5 7.2 8.0 6.5 7.0 7.5 6.5 7.2 8.0 0601 -1200 7.5 8.8 10.5 6.5 7.0 8.0 6.5 7.0 7.5 6.5 6.5 6.5 1201 -1800 12.5 13.2 13.5 10.0 10.8 12.0 9.5 10.5 11.5 7.0 8.0 9.0 1801 -2400 10.0 11.3 12.5 9.0 10.2 11.5 9.0 10.0 11.0 9.0 9.3 9.5-DAILY VALUE 7.5 10.4 13.5 6.5 8.8 12.0 6.5 8.6 11.5 6.5 7.7 9.5 0001 -0600 8.0 8.5 9.0 7.5 7.8 8.5 7.0 7.5 8.0 7.5 '8.0 8.5 0601 -1200 8.0 8.8 10.0 7.5 7.8 8.5 6.5 6.8 7.5 7.0 7.2 7.5 12fll -1800 12.5 13.0 13.5 10.5 11.7 12.5 9.5 11.2 12.5 8.0 8.2 8.5 1801 -2400 10.0 11.0 12.0 10.0 11.0 12.0 9.5 10.8 12.0 8.0 8.3 8.5 DAILY VALUE 8.0 10.3 13.5 7.5 9.6 12.5 6.5 9.1 12.5 7.0 7.9 8.5 0001 -0600 7.5 8.3 9.0 8.5 8.7 9.0 7.0 "7.7 8.5 7.0 7.5 8.0 0601 -1200 7.'5 8.2 9.5 8.0 8.0 8.0 6.5 6.7 7.0 7.0 7.0 7.0 1201 -1800 10.5 11.5 12.5 8.0 8.5 9.0 8.5 10.5 12.0 7.5 7.7 8.0 .....1801 -'2400 9.5 10.8 12.0 8.5 8.8 9.0 10.0 11.2 12.5 7.5 7.7 8.0 DAILY VALUE 7.5 9.7 12.5 8.0 8.5 9.0 6.5 9.0 12.5 7.0 7.5 8.0 0001 -0600 7.5 8.0 8.5 7.0 7.5 8.0 8.0 8.5 9.0 7.0 7.0 7.0 0601 -1200 7.5 7.8 8.5 7.0 7.5 8.0 8.0 8.2 8.5 7.0 7.0 7.0 1201 -1800 10.0 10.3 10.5 9.0 10.5 11.5 9.0 9.8 10.5 7.5 8.2 9.0 1801 -2400 8.5 9.3 JO.O 9.0 10.0 11.0 9.5 10.3 11.0 8.0 8.5 9.0 DAILY VALUE 7.5 8.9 10.5 7.0 8.9 11.5 8.0 9.2 11.0 7.0 7.7 9.0 0001 -0600 7.0 7.5 8.0 7.5 7.8 8.0 8.0 8.3 9.0 -------------- 0601 -1200 6.5 7.3 8.5 7.5 8.2 9.0 7.5 7.7 8.0 MONTHLY VALUE 1201 -1800 11.0 11.7 12.0 10.5 11.7 12.5 8.5 9.7 11.0 --------------- 1801 -2400 9.5 10.3 11.5 9.5 10.7 12.0 10.0 10.5 11.0 6.0 8.9 13.5 DAILY VALUE 6.5 9.2 12.0 7.5 9.6 12.5 7.5 9.0 11.0 -------------------------------------------------------------------------------- 4-C-55 Table 4-C-1S.-Cont. """- -SEPTEMBER 1982 - -----------------------------------------~-------------------------------------TIME DAYS 1 -8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ------------------------------------------------------------------------------- 0001 -0600 7.5 7.5 7.5 7.0 7.2 7.5 -------3.9 4.1 4.4 0601 -1200 7.5 7.7 8.0 7.0 7.0 7.0 -------3.4 3.7 4.4 1201 -1800 9.0 10.2 11.0 7.0 7.7 8.0 -------4.9 5.2 5.4 1801 -2400 8.5 9.2 10.0 7.5 7.8 8.0 ------4.9 5.1 5.4 DAILY VALUE 7.5 8.6 11.0 7.0 7.4 8.0 --------3.4 4.5 5.4 "'"'" 0001 -0600 7.5 7.7 8.0 6.5 6.8 7.0 -------..---4.9 4.9 4.9 0601 -1200 7.0 7.2 7.5 6.5 6.7 7.0 -.---------4.9 4.9 4.9 1201 -1800 8.0 8.7 9.5 7.5 7.8 8.0 .......-----5.4 5.4 5.4 ~ 1801 -2400 8.0 8.7 9.0 7.5 7.8 8.0 -------4.9 5.1 5.4 DAlLY VALUE 7.0 8.0 9.5 6.5 7.3 8.0 ----------4.9 5.1 5.4 0001 -0600 7.5 7.7 8.0 6.5 6.7 7.0 ,--------4.9 4.9 4.9 0601 -1200 7.5 7.5 7.5 6.5 6.5 6.5 ------4.9 4.9 4.9 1201 -1800 7.5 7.7 8.0 6.5 6.8 7.0 -------5.4 5.6 5.9 1801 -2400 7.5 7.8 8.0 6.5 6.8 7.0 -------4.4 4.9 5.4 DAILY VALUE 7.5 7.7 8.0 6.5 6.7 7.0 ----..---4.4 5.1 5.9 0001 -0600 7.0 7.0 7.0 5.5 5.7 6.0 --------3.4 3.7 3.9 0601 -1200 7.0 7.0 7.0 5.0 5.2 5.5 ----3.4 3.6 3.9 1201 -1800 7.5 8.3 9.0 6.0 6.8 7.5 6.9 6.9 6.9 4.4 4.7 4 •.9 1801 -2400 7.5 8.0 8.5 6.5 7.0 7.5 6.4 6.4 6.4 4.9 4.9 4.9 DAILY VALUE 7.0 7.6 9.0 5.0 6.2 7.5 6.4 --6.9 3.4 4.2 4.9 0001 -0600 6.5 6.7 7.0 6.0 6.2 6.5 6.4 6.4 6.4 4.4 4.4 4.4 0601 -1200 6.5 6.7 7.0 6.0 6.0 6.0 6.4 6.4 6.4 4.4 4.4 4.4 1201 -1800 7.5 7.8 8.0 6.0 6.3 6.5 6.4 6.4 6.4 4.9 5.4 5.9 1801 -2400 7.5 7.8 8.0 6.5 .6.5 6.5 5.9 6.2 6.4 4.9 5.2 5.4 ~ DAlLY VALUE 6.5 7.2 8.0 6.0 6.2 6.5 5.9 6.4 6.4 4.4 4.9 5.9 0001 -0600 7.0 7.2 7.5 -------5.9 5.9 5.9 4.9 4.9 4.9 0601 1200 7.0 7.0 7.0 5.9 5.9 5,9 4.9 4.9 4.9 "'"'"--------- 1201 -1800 7.5 7.8 8.0 ----------6.4 6.6 6.9 5.4 5.6 5.9 1801 ...2400 7.5 7.7 8.0 ---------4.9 5.4 5.9 4.9 5.2 5.4 DAILY VALUE 7.0 7.4 8.0 ----- ---4.9 5.9 6.9 4.9 5.1 5.9 ..., 0001 -0600 7.0 7.0 7.0 --------4.9 4.9 4.9 -------- 0601 -1200 7.0 7.2 7.5 -------4.9 4.9 4 •.9 --------- 1201 -1800 8.0 8.5 9.0 ....---------5.9 5.9 5.9 ----- ---"""1801 -2400 8.0 8.2 8.5 ----------3.9 4.7 5.4 --------- DAILY VALUE 7.0 7.7 9.0 ---- -------3.9 5.1 5.9 ---------- 0001 -0600 7.0 7.3 7.5 --------3.4 3.6 3.9 -----------,11IWQ. 0601 -1200 7.0 7.2 7.5 ---- ---- ---- 2.9 3.2 3.9 MONTHLY VALUE 1201 -1800 8.0 8.2 8.5 ------ ---- 4.9 5.2 5.4 -----------1801 -2400 7.5 8.0 8.5 ---------4.9 5.1 5.4 2.9 6.4 11.0 DAILY VALUE 7.0 7.7 8.5 --- -------2.9 4.3 5.4 -------------------------------------------------------------------------------- ~, 4-C-56 - -Table 4-C-15.Cont. "-,,.JW~ -OCTOBER 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ------------------------------------------------------------------------- 0001 ...0600 4.9 4.9 4.9 1.7 1.7 1.7 1.7 1.7 1.7 .7 .7 .7 0601 -1200 4.4 4.4 4.4 2.2 2.4 2.7 1.7 2.0 2.2 .7 .9 1.2 1201 -1800 4.7 4.7 4.7 3.2 3.4 3.7 2.7 2.7 2.7 1.2 1.2 1.2 1801 -2400 3.7 3.9 4.2 2.7 2.9 3.2 1.7 2.0 2.2 .7 .9 1.2 DAILY VALUE 3.7 4.5 4.9 1.7 2.6 3.7 1.7 2.1 2.7 .7 .9 1.2 0001 -0600 3.7 3.7 3.7 2.7 2.7 2.7 1.7 1.7 1.7 .7 .7 .7 0601 -1200 3.7 3.9 4.2 2.7 2.7 2.7 1.7 1.7 1.7 .7 .7 .7 1201 -1800 4.7 5.0 5.2 3.2 3.2 3.2 2.2 2.2 2.2 .7 .7 .7 1801 -2400 3.7 4.2 4.7 2.7 2.7 2.7 2.2 2.2 2.2 .7 .7 .7 DAILY VALUE 3.7 4.2 5.2 2.7 2.8 3.2 1.7 1.9 2.2 .7 .7 .7 I'- 0001 -0600 3.2 3.5 3.7 2.2 2.2 2.2 2.2 2.2 2.2 .7 .7 .7 0601 -1200 3.2 3.4 3.7 2.2 2.2 2.2 1.7 1.9 2.2 .7 .7 .7 1201 -1800 3.7 4.0 4.2 2.2 2.4 2.7 1.7 2.0 2.2 .7 .7 .7 1801 -2400 3.7 3.9 4.2 2.2 2.2 2.2 2.2 2.2 2.2 .7 .7 .7 DAILY VALUE 3.2 3.7 4.2 2.2 2.2 2.7 1.7 2.1 2.2 .7 .7 .7 0001 -0600 2.7 2.9 3.2 1.7 1.7 1.7 2.2 2.2 2.2 .7 .7 .7 F"'~_,0601 -1200 2.2 2.2 2.2 1.7 1.7 1.7 1.7 2.0 2.2 .7 .7 .7 1201 -1800 2.7 3.0 3.2 2.2 2.4 2.7 2.2 2.2 2.2 .7 .7 .7 1801 -2400 2.2 2.7 3.2 2.2 2.2 2.2 1.7 1.9 2.2 .7 .7 .7 DAILY VALUE 2.2 2.7 3.2 1.7 2.0 2.7 1.7 2.1 2.2 .7 .7 .7 0001 -0600 1.7 1.9 2.2 1.7 1.9 2.2 1.2 1.4 1.7 .7 .7 .7 0601 -1200 1.7 1.7 1.7 1.7 1.7 1.7 1.2 1.2 1.2 07 .9 1.2 !"""1201 -1800 2.2 2.5 2.7 2.2 2.2 2.2 1.2 1.4 1.7 1.2 1.2 1.2 1801 -2400 1.7 2.0 2.2 2.2 2.2 2.2 1.2 1.2 1.2 .7 .7 .7 DAILY VALUE 1.7 2.0 2.7 1.7 2.0 2.2 1.2 1.3 1.7 .7 .9 1.2 0001 -0600 1.2 1.4 '1.7 1.7 1.7 1.7 1.2 1.2 1.2 .7 .7 .7 0601 -1200 1.2 1.4 1.7 1.7 1.7 1.7 1.2 1.2 1.2 .7 .7 .7 1201 -1800 2.2 2.5 2.7 2.2 2.4 2.7 1.2 1.5 1.7 ----------- 1801 -2400 2.7 2.7 2.7 1.2 1.7 2.2 1.2 1.4 1.7 ---------- ~~DAILY VALUE 1.2 2.0 2.7 1.2 1.9 2.7 1.2 1.3 1.7 .7 ---.7 0001 -0600 2.2 2.2 2.2 1.2 1.5 1.7 1.2 1.2 1.2 ---------- 0601 -1200 2.2 2.2 2.2 1.2 1.4 1.7 1.2 1.2 1.2 ------------ 1201 -1800 2.2 2.5 2.7 1.7 2.0 2.2 1.2 1.4 1.7 ---------- 1801 -2400 2.2 2.5 2.7 1.7 1.7 1.7 1.2 1.2 1.2 --..---------- DAILY VALUE 2.2 2.4 2.7 1.2 1.7 2.2 1.2 1.2 1.7 --'-------- 0001 -0600 1.7 1.9 2.2 1.7 1.7 1.7 1.2 1.2 1.2 ------------ 0601 -1200 1.7 2.0 2.2 1.7 1.7 1.7 1.2 1.2 1.2 MONTHLY VALUE 1201 -1800 2.7 3.0 3.2 1.7 1.7 1.7 1.2 1.5 1.7 ------------- 1801 -2400 1.7 2.2 2.7 1.7 1.7 1.7 1.2 1.4 1.7 .7 2.0 5.2 DAILY VALUE 1.7 2.3 3.2 1.7 1.7 1.7 1.2 1.3 1.7 ----------------------------------------------------~--------------------------- .....4--C-57 4-C-59 4-C-60 Table 4-C-17.Cont. -AUGUST 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX. DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX ",... 0001 0600 6.5 6 .7 7.0 0601 1200 6.0 6.8 8.0 1201 1800 9.0 9.3 9.5 1801 2400 7.5 8.0 8.5 DAILY VALUE 6.0 7.7 9.5 0001 0600 6.0 6.5 7.0 0601 1200 6.0 7.0 8.0 1201 1800 9.0 9.3 9.5 1801 2400 7.5 8.3 9.0 DAILY VALUE 6.0 7.8 9.5 0001 0600 6.5 6 .7 7.0 0601 1200 6.5 7.3 8.5 1201 1800 9.5 9.8 10.0 1801 2400 8.5 8.8 9.5 DAILY VALUE 6.5 8.2 10.0 0001 0600 6.5 7.0 7.5 0601 1200 6.5 7.5 8.5 -- 1201 1800 1801 2400 DAILY VALUE 6.5 8.5 0001 0600 0601 1200 --"---.- 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 ......... 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 4-C--61 MONTHLY VALUE 6.0 ---10.0 ~~,-Table 4-C-18.Cont • .- -SEPTEMBER 1982 - --------------------------------------------------------------------------------.-TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 8.2 8.5 8.7 7.9 7.9 7.9 ------------------------ 0601 -1200 8.2 8.2 8.2 7.9 7.9 7.9 ---------------------- 1201 -1800 8.4 8.4 8.4 7.9 7.9 7.9 --------------------- 1801 -2400 8.4 8.7 8.9 7.9 7.9 7.9 ---------------------- .DAILY VALUE 8.2 8.5 8.9 7.9 7.9 7.9 ---------------------- 0001 -0600 8.4 8.6 8.9 7.4 7.7 7.9 -------------------- 0601 -1200 7.9 8.2 8.4 7.4 7.4 7.4 -------------------- 1201 -1800 8.4 8.4 8.4 7.9 7.9 7.9 --------------------- 1801 -2400 8.4 8.4 8.4 7.4 7.4 7.4 -------------------- DAILY VALUE 7.9 8.4 8.9 7.4 7.6 7.9 ------------------------ 0001 -0600 8.4 8.4 8.4 6.9 6.9 6.9 --_..------------------- 0601 -1200 8.4 8.4 8.4 6.9 6.9 6.9 ---------------------- 1201 -1800 8.4 8.4 8.4 6.9 .6.9 6.9 ------------------ 1801 -2400 8.4 8.4 8.4 6.4 6.4 6.4 ---------------.----- DAILY VALUE 8.4 8.4 8.4 6.4 6.8 6.9 ---------------------- 0001 -0600 7.9 8.1 8.4 5.9 6.2 6.4 ----------------------- 0601 -1200 7.9 7.9 7.9 5.9 6.2 6.4 --------------------- 1201 -1800 7.9 8.2 8.4 6.4 6.4 6.4 -------------------- 1801 -2400 7.9 8.1 8.4 6.4 6.4 6.4 ------------------- DAILY VALUE 7.9 8.1 8.4 5.9 6.3 6.4 -------------------- 0001 -0600 7.9 7.9 7.9 6.4 6.4 6.4 --""'!"--------------------- 0601 -1200 7.9 7.9 7.9 6.4 6.4 6.4 -----------------------1201 -1800 .,.9 7.9 7.9 6.4 6.4 6.4 -------------------- 1801 -2400 7.9 7.9 7.9 6.4 6.4 6.4 --------------------- DAILY VALUE 7.9 7.9 7.9 6.4 6.4 6.4 ------------------- ---- ,.,..0001 0600 7.9 7.9 7.9 6.9 6.9 6.9-------------------- ---- 0601 -1200 7.9 7.9 7.9 6.9 6.9 6.9 ------------------- ---- 1201 -1800 7.9 8.2 8.4 -------------------------------- 1801 -2400 8.4 8.4 8.4 ------------------ ------------ ---- DAILY VALUE 7.9 8.1 8.4 6.9 ----6.9 ----------------------- 0001 -0600 8.4 8.4 8.4 ------------------------------------ 0601 -1200 8.4 8.6 8.9 ---------------------------------- 1201 -1800 8.9 8.9 8.9 ----------------------------------- 1801 -2400 8.9 8.9 8.9 ------------------------------------ DAILY VALUE 8.4 8.7 8.9 ------------------------------------ 0001 -0600 8.4 8.7 8.9 ----------------------------------0601 -1200 8.4 8.4 8.4 ---------------------MONTHLY VALUE 1201 -1800 8.4 8.4 8.4 ------------------------------------1801 -2400 7.9 8.1 8.4 ----------------------5.9 ---8.9 DAILY VALUE 7.9 8.4 8.9 ----------------- -------- -------------------------------------------------------------------------------- 4--C-63 Table 4-C-19.Thermograph data summary,summer surface water temperature (C), Slough 21~Area of R&M Stage Recorder,RM 142.0,Geocode S32N02W36CCC. -JULY 1982 - ...., TIME PERIOD DAYS 1 - 8 MIN MEAN MAX. DAYS 9 -16 MIN MEAN MAX. DAYS 17 -24 MIN MEAN MAX. DAYS 25 -31 MIN MEAN MAX 0001 0600 -- 0601 1200 1201 1800 1801 2400 DAILY VALUE - 0001 0600 ----0601 1200 1201 1800 --..-.... 1801 2400 DAILY VALUE 0001 0600 ~ 0601 1200 ---- 1201 1800 1801 2400 .........---~DAILY VALUE 0001 0600 0601 1200 7.S 7.S ~.. 1201 1800 7.5 8.2 8.5 1801 2400 --------6.0 6.2 6.5 DAILY VALUE 6.0 8.5 .,., 0001 0600 5.5 5.5 5.5 0601 1200 5.5 6.0 6.5 1201 1800 6.0 6.3 6.5 1801 2400 5.5 5.7 6.0 DAILY VALUE 5.5 5.9 6.5 0001 0600 5.5 5.5 5.5 0601 1200 5.5 5.7 6.0 1201 1800 7.5 8.0 8.5 1801 2400 8.5 8.5 8.5 DAILY VALUE 5.5 6.9 8.5 0001 0600 8.5 8.5 8.5 0601 1200 8.5 8.7 9.0 1201 1800 9.0 9.0 9.0 "'" 1801 2400 8.5 8.7 9.0 DAILY VALUE 8.5 8.7 9.0 0001 0600 -------------- 0601 1200 MONTHLY VALUE 1201 1800 -------------- 1801 2400 5.5 ---9.0 ~ DAILY VALUE 4-C-64 - 4-C-65 4-C-66 .... 4-C-67 Tab1e4-C-20.Thermograph data summary,summer surface water temperature (C), Portage Creek,RM 148.8,TRM 0.1 ,Geocode S32NOIW25CAB.~ ~, -JUNE 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX - 0001 -0600 ----------2.2 2.4 2.7 ------- ----4.0 4.2 4.5 0601 -1200 -----------2.2 2.4 2.7 ----------4.0 5.3 7.0 1201 -1800 ---------3.2 3.7 4.2 -----------7.5 7.5 7.5 1801 -2400 -----------3.2 3.7 4.2 ----------5.0 6.0 7.0 DAILY VALUE -------- ---- 2.2 3.0 4.2 ---------4.0 5.7 7.5 0001 -0600 ---------2.2 2.7 3.2 --...--------4.0 4.2 4.5 0601 -1200 ----------2.2 2.7 3.2 ----------4.5 5.7 7.0 1201 -1800 ---------3.7 4.2 4.7 -----------7.0 7.7 8.0 1801 -2400 ------------3.2 4.0 4.7 -----------5.0 6.0 7.0 DAILY VALUE -----------2.2 3.4 4.7 -----------4.0 5.9 8.0 0001 -0600 ------ ---- 2.2 2.4 2.7 -----------4.0 4.2 4.5 0601 -1200 ----------2.2 2.7 3.2 -----------4.5 5.5 6.5 1201 -1800 -----------3.2 3.7 4.2 -----------7.5 7.5 7.5 1801 -2400 ------------3.7 4.0 4.2 --- ------5.5 6.3 7.0 DAILY VALUE ------------2.2 3.2 4.2 -----------4.0 5.9 7.5 0001 -0600 ----------2.7 2.9 3.2 ----------5.0 5.0 5.0 0601 -1200 -----------2.7 2.9 3.2 ---------5.5 6.2 7.0 1201 -1800 ------------4.2 4.4 4.7 ---------7.5 7.5 7.5 1801 -2400 -----------2.7 3.2 3.7 ---------5.5 6.0 6.5 DAILY VALUE -----------2.7 3.3 4.7 -----------5.0 6.2 7.5 0001 -0600 ----------1.7 2.0 2.2 -----------4.5 4.8 5.0 0601 -1200 -----------2.2 2.9 3.7 ----------4.5 5.0 5.5 1201 -1800 ----------4.2 4.5 4.7 ----------6.5 6.8 7.0 1801 -2400 -----------4.2 4.5 4.7 ----------5.5 6.3 7.0 DAILY VALUE ------------1.7 3.5 4.7 --- --- ----4.5 5.7 7.0 0001 -0600 ---------------------------------5.0 5.2 5.5 0601 -1200 -------------------------------5.0 5.5 6.0 1201 -1800 ----------------------------------6.5 6.5 6.5 1801 -2400 -------------------------------5.5 6.0 6.5 DAILY VALUE --------------------------------5.0 5.8 6.5 0001 -0600 ------------------------------------------ 0601 -1200 -------------------------------------- 1201 -1800 ------------------------------------------- 1801 -2400 -------------------------------------------- DAILY VALUE -------- ------------------------------------ OQOl -0600 ----------------------4.0 4.2 4.5 -..------------- 0601 -1200 3.2 ----3.2 -----------4.5 5.7 7.0 MONTHLY VALUE 1201 -1800 4.2 4.5 4.7 ----------8.0 8.3 8.5 ---------------1801 -2400 3.2 4.0 4.7 ------------5.0 6.2 7.5 1.7 ----8.5 DAILY VALUE 3 .2 ----4.7 ------------4.0 6.1 8.5 -------------------------------------------------------------------------------- 4-C-68 - ..... ~, ..... Table 4-G-20.Cpnt. -JULY 1982 ---------------------------------------------------------------------------------.-TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------~--------------------------~--------------------------------- 0001 -0600·4.5 4.8 5.0 6.'5 7.0 7.5 6.5 7.0 7.5 6.0 6.2 6.5 0601 -1200 4.5 5.0 5.5 6.5 7.0 7.5 6.5 7.0 7.5 6.0 6.0 6.0 1201 -1800 6.0 6.3 6.5 8.0 8.3 8.5 8.5 9.0 9.5 6.5 6.5 6.5 1801 -2400 5.5 6.0 6.5 8.0 8.3 8.5 8.5 9.0 9.5 6.0 6.2 6.5 DAILY VALUE 4.5 5.5 6.5 6.5 7.7 8.5 6.5 8.0 9.5 6.0 6.2 6.5 0001 -0600 4.5 4.8 5.0 6.5 7.0 7.5 7.0 7.5 8.0 6.0 6.0 6.0 0601 -1200 --------6.5 6.7 7.0 7.0 7.0 7.0 6.0 6.0 6.0 1201 -1800 -----.-7.5 7.5 7.5 7.0 7.5 8.0 6.0 6.3 6.5 1801 -2400 ---------7.5 7.5 7.5 7.5 7.8 8.0 6.5 6.5 6.5 DAILY VALUE 4.5 ---5.0 6.5 7.2 7.5 7.0 7.5 8.0 6.0 6.2 6.5 ,~ 0001 -0600 -------6.5 6.8 7.0 6.0 6.5 7.0 6.0 6.3 6.5 0601 -1200 ----------6.5 6.7 7.0 6.0 7.0 8.5 6.0 6.2 6.5 1201 -1800 ------8.0 8.2 8.5 9.5 10.3 11.0 7.0 7.5 8.0 1801-2400 ---------7.5 8.0 8.5 .9.5 10.3 11.0 7.5 7.7 8.0 DAILY VALUE ----------6.5 7.4 8.5 6.0 8.5 11.0 6.0 6.9 8.0 ,~~0001 -0600 ------7.0 7.0 7.0 7.0 7.7 8.5 7.0 7.0 7.0 0601 -1200 -------6.5 6.7 7.0 7.0 7.8 9.0 7.5 ----7.5 1201 -1800 -------7.0 7.2 7.5 10.5 11.2 11.5 8.5 9.0 9.5 1801 -2400 ---------7.0 7.2 7.5 10.5 11.2 11.5 8.5 8.8 9.0.-DAILY VALUE -----------6.5 7.0 7.5 7.0 9.511.5 7.0 8.2 9.5 0001 -0600 ----------6.5 6.5 6.5 8.0 8.7 9.5 7.5 7.7 8.0 0601 -1200 --------6.5 6.7 7.0 8.0 8.0 8.0 7.5 7.5 7.5r-1201 -1800 -------8.0 8.7 9.5 8.0 8.3 8.5 7.5 7.8 8.0 1801 -2400 --- -------8.0 8.5 9.0 8.0 8.3 8.5 7.5 7.5 7.5 DAlLY VALUE ---------6.5 7.6 9.5 8.0 8.3 9.5 7.5 7.6 8.0 i~0001 -0600 ----- ---- 6.5 7.0 7.5 7.5 7.7 8.0 7.0 7.0 7.0 0601 -1200 ----------6.5 7.2 8.0 7.0 7.3 7.5 7.0 7.0 7.0 1201 -1800 -----------8.5 9.0 9.5 7.5 7.5 7.5 7.0 7.3 7.5 1801 -2400 -------8.0 8.5 9.0 7.0 7.3 7.5 7.5 7.5 7.5 DAILY VALUE --------6.5 7.9 9.5 7.0 7.5 8.0 7.0 7.2 7.5 0001 -0600 ----,-------7.0 7.2 7.5 7.0 7.0 7.0 7.5 7.5 7.5 0601 -1200 -----------7.0 7.2 7.5 6.5 6.5 6.5 ---------- 1201 -1800 ----------8.5 8.8 9.0 7.0 7.0 7.0 ----------- 1801 -2400 ----------8.0 8.3 8.5 6.5 6.7 7.0 ----------- DAILY VALUE ----------7.0 7.9 9.0 6.5 6.8 7.0 7.5 ----7.5 0001 -0600 ----------7.0 7.2 7.5 6.5 6.5 6.5 --------------- 0601 -1200 --------6.5 6.8 7.0 6.5 6.5 6.5 MONTHLY VALUE 1201 -1800 9.5 ---9.5 7.5 8.0 8.5 6.5 6.5 6.5 --------------- 1801 -2400 8.0 8.5 9.0 7.5 8.0 8.5 6.5 6.5 6.5 4.5 7.4 11.5 DAILY VALUE 8.0 ---9.5 6.5 7.5 8.5 6.5 6.5 6.5.- ------------------------------------------------------------------------------- 4-C-69 Table 4-C-20.Cont.~ fii'"--AUGUST 1982 - --------------------------------------------------------------------------------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN ~MIN MEAN MAX ~ -------------------------------------------------------------------------------- 0001 -0600 ------7.5 7.8 8.0 B.O 8.5 9.0 8.5 8.8 9.0 0601 -1200 ----7.5 7.5 7.5 7.5 7.7 8.0 8.0 8.2 8.5 1201 -1800 -----7.5 7.5 7.5 8.0 8.2 8.5 9.0 9.5 10.0 1801 -2400 -------7.5 7.5 7.5 7.5 B.O 8.5 9.0 .9.5 10.0 DAILY VALUE ---------7.5 7.6 B.O 7.5 B.1 9.0 8.0 9.0 10.0 ~ 0001 -0600 --------7.0 7.2 7.5 6.5 6.8 7.0 8.5 8.7 9.0 0601 -1200 ----7.0 7.0 7.0 7.0 7.2 7.5 8.0 8.0 8.0 1201 -1800 ------7.5 7.7 8.0 8.0 B.3 8.5 9.0 9.5 10.0 ~ 1801 -2400 ---------7.5 7.7 8.0 8.0 8.3 8·.5 9.0 9.5 10.0 DAILY VALUE ------- ----7.0 7.4 8.0 6.5 7.7 8.5 8.0 B.9 10.0 0001 -0600 --------7.0 7.2 7.5 6.5 7.0 7.5 6.5 7.3 8.0 0601 -1200 -------7.0 7.2 7.5 ,6.5 6.7 7.0 6.0 6.2 6.5 1201 -1800 --..----8.5 9.0 9.5 8.0 8.8 9.5 8.0 8.7 9.0 1801 -2400 ---------8.0 8.8 9.5 9.0 9.5 10.0 8.5 8.8 9.0 DAILY VALUE ---------7.0 8.0 9.5 6.5 8.0 10.0 6.0 7.7 9.0 ~. 0001 -0600 -----------6.0 6.7 7.5 7.5 7.8 8.5 6.5 7.0 7.5 0601 -1200 8.5 --,8.5 5.5 6.2 7.0 7.0 7.3 8.0 6.5 6.5 6.5 .~~1201 -1800 9.0 9.8 10.5 8.5 9.0 9.5 9.0 10.0 10.5 7.0 7.5 8.0 1801 -2400 9.0 9.8 10.5 9.0 9.3 9.5 9.5 9.8 10.0 8.0 8.0 8.0 DAILY VALUE 8.5 --10.5 5.5 7.8 9.5 7.0 B.7 10.5 6.5 7.2 8.0 ~ 0001 -0600 7.0 7.7 8.5 7.0 7.5 8.0 7.5 8.0 8.5 7.5 7.5 7.5 0601 -1200 7.0 7.3 8.0 6.5 7.0 8.0 6.5 7.0 7.5 7.0 7.2 7.5 1201 -1800 9.0 9.3 9.5 9.5 10.0 10.5 9.0 9.5 10.0 7.5 7.B 8.0 1801 -2400 9.0 9.2 9.5 10.0 10.3 10.5 9.5 9.B 10.0 7.5 7.B 8.0 DAILY VALUE 7.0 8.4 9.5 6.5 8.7 10.5 6.5 8.6 10.0 7.0 7.6 8.0 0001 -0600 7.0 7.5 8.0 8.5 9.0 9.5 7.0 7.8 8.5 7.0 7.3 7.5 0601 -1200 7.0 7.3 B.O 8.5 8.5 B.5 6.5 6.8 7.5 7.0 7.0 7.0 ~ 1201 -1800 9.0 9.B 10.5 B.5 8.5 8.5 9.0 9.5 10.0 7.0 7.0 7.0 1801 -2400 9.0 9.5 10.0 8.5 8.8 9.0 10.0 10.0 10.0 7.0 7.0 7.0 DAILY VALUE 7.0 8.5 10.5 8.5 8.7 9.5 6.5 B.5 10.0 7.0 7.1 7.5 -, 0001 -0600 7.0 7.5 8.0 B.O 8.2 B.5 9.0 9.2 9.5 6.0 6.3 6.5 0601 -1200 7.0 7.3 8.0 8.0 8.2 B.5 B.5 8.5 B.5 6.0 6.0 6.0 1201 -1800 8.5 8.8 9.0 9.0 9.3 9.5 9.0 9.0 9.0 ------------~ 1801 -2400 8.5 8.7 \9.0 8.5 9.0 9.5 9.0 9.3 9.5 ------------ DAlLY VALUE 7.0 8.1 9.0 8.0 8.7 9.5 8.5 9.0 9.5 6.0 ---6.5 0001 -0600 7.0 7.5 8.0 7.5 8.0 8.5 8.0 8.3 8.5 -------------- 0601 -1200 6.5 7.2 8.0 7.5 7.8 8.5 8.0 8.2 8.5 MONTHLY VALUE 1201 -1800 8.5 9.0 9.5 9.5 9.8 10.0 9.0 9.7 10.0 ------------- 1801 -2400 8.5 9.0 9.5 9.5 9.7 10.0 9.5 9.8 10.0 5.5 8.2 10.5 DAILY VALUE 6.5 8.2 9.5 7.5 8.8 10.0 8.0 9.0 10.0 -------------------------------------------------------------------------------- 4-C-70 f""" Table 4-C-21.Thennograph data summary,summer surface water temperature (eL ~.;,:"Vl:iio:"'\Tsusena Creek,RM 181.3,Geocode S32N04E36ADB. I"'"-JUNE 1982 --------------------------------------------------------------------------------- i""'"TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX --------.------------------------------------------------------------ .....0001 -0600 -------------------------4.0 4.5 5.0 0601 -1200 --------------------- ---- 4.0 5.3 7.0 1201 -1800 ---------------------8.0 8.5 9.0 1801 -2400 ------------------------6.5 7.7 8.5 DAILY VALUE --- ----------------------4.0 6.5 9.0 0001 -0600 ----------------------4.5 4.8 5.5 ~0601 -1200 -------_._------------4.5 5.3 6.5 1201 -1800 --------------------,8.0 8.5 9.0 1801 -2400 -------------------------6.5 7.8 9.0 r-DAILY VALUE ----------------------4.5 6.6 9.0 0001 -0600 ------------------------4.5 4.8 5.5 0601 -1200 ----------- ----------4.5 5.3 6.5 1201 -1800 -------------7.0 7.7 8.0 8.0 8.8 9.5 1801 -2400 - - -- -- ------6.5 7.3 8.0 7.0 8.3 9.5 DAILY VALUE --------------6.5 8.0 4.5 6.8 9.5 ~,~, 0001 0600--------------4.5 5.2 6.0 5.5 6.0 6.5 0601 -1200 ------------------4.0 4.0 4.0 5.5 6.2 7.0 1201 -1800 ----------4.0 4.2 4.5 8.0 8.3 8.5 1801 -2400 --------------4.5 4.5 4.5 6.5 .7.3 8.0 DAILY VALUE -----------------4.0 4.5 6.0 5.5 7.0 8.5 0001 -0600 ------------------4.0 4.0 4.0 5.0 5.2 5.5 0601 -1200 ----------4.0 4.2 4.5 5.0 5.5 6.0 1201 -1800 ------------5.5 6.5 7.5 6.5 7.3 8.0 1801 -2400 ----------------6.5 7.5 8.0 7.5 7.8 8.0......DAILY VALUE ------------4.0 5.5 8.0 5.0 6.5 8.0 0001 -0600 ---- ------------4.5 5.2 6.0 5.5 6.0 6.5 0601 -1200 ------------------4.5 5.2 6.0 5.5 5.7 6.0.- 1201 -1800 --------------7.0 7.5 8.0 7.0 7.3 7.5 1801 -2400 ----- -------7.0 7.5 8.0 6.5 7.0 7.5 DAILY VALUE ---------------4.5 6.3 8.0 5.5 6.5 7.5-0001 -0600 --------------4.5 5.2 6.0 ----------- 0601 -1200 ----------4.5 5.5 7.0 ---------- 1201 -1800 ------------8.5 9.5 10.0 ---------- 1801 -2400 ---------------6.5 8.2 9.5 -------- DAILY VALUE -----------------4.5 7.1 10.0 ---------- I""'"0001 -0600 --------------4.0 4.7 5.5 -_...._--------- 0601 -1200 -------------4.0 5.2 6.5 MONTHLY VALUE 1201 -1800 ---------------8.5 9.7 10.5 ------------ 1801 -2400 ----------------6.5 8.0 9.5 4.0 ---10.5.-DAILY VALUE 4.0 6.9 10.5-------------------- --------------------------------------------------------------------------------....4-C-71 Table 4-C-21.cont.- ,Ail' -SEPTEMB~R 1982 --------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX '"""-------------------------------------------------------------------------------- 0001 -0600 6.5 6.7 7.0 6.0 6.2 6.5 4.5 4.7 5.0 3.5 3.7 4.0 0601 -1200 6.5 6.5 6.5 6.0 6.0 6.0 4.5 4.5 4.5 3.0 3.3 3.5 ~ 1201 -1800 7.5 8.0 8.5 6.5 6.8 7.0 5.0 5.3 5.5 4.5 5.0 5.5 1801 -2400 7.0 7.8 8.5 6.5 6.8 7.0 5.0 5.3 5.5 5.0 5.3 5.5 DAILY VALUE 6.5 7.2 8.5 6.0 6.5 7.0 4.5 5.0 5.5 3.0 4.3 5.5 ~ 0001 -0600 6.0 6.2 6.5 6.0 6.3 6.5 4.5 4.7 5.0 4.5 4.7 5.0 0601 -1200 6.0 6.2 6.5 6.0 6.0 6.0 4.5 4.7 5,0 4.0 4.3 4.5 1201 -1800 7.5 8.2 8.5 6.0 6.3 6.5 5.5 5.8 6.0 4.5 4.8 5.0 ~. 1801 -2400 7.5 7.8 8.0 6.0 6.3 6.5 6.0 6.0 6.0 4.5 4.5 4.5 DAILY VALUE 6.0 7.1 8.5 6.0 6.2 6.5 4.5 5.3 6.0 4.0 4.6 5.0 0001 -0600 6.5 6.7 7.0 5.5 5.7 6.0 5.5 5.5 5.5 4.0 4.3 4.5 0601 -1200 6.5 6.5 6.5 5.0 5.2 5.5 5.5 5.5 5.5 4.0 4.3 4.5 1201 -1800 6.5 6.7 7.0 5.5 5.5 5.5 5.5 5.7 6.0 5.0 5.2 5.5 1801 -2400 6.5 6.7 hO 5.5 5.5 5.5 5.5 5.8 6.0 4.0 4.7 5.5 ~ DAILY VALUE 6.5 6.6 7.0 5.0 5.5 6.0 5.5 5.6 6.0 4.0 4.6 5.5 0001 -0600 5.5 5.7 6.0 5.0 5.2 5.5 5.0 5.2 5.5 2.5 3.0 3.5 0601 -1200 5.5 5.7 6.0 4.5 4.5 4.5 5.0 5.2 5.5 2.5 2.7 3.0 /!I!IIm,,.,- 1201 -1800 7.0 7.3 7.5 5.5 6.2 6.5 5.5 5.8 6.0 3.5 3.5 3.5 1801 -2400 6.5 7.2 7.5 6.5 6.5 6.5 5.5 5.5 5.5 3.5 3.5 3.5 DAILY VALUE 5.5 6.5 7.5 4.5 5.6 6.5 5.0 5.4 6 .0 2.5 3.2 3.5 ~ 0001 -0600 5.5 5.8 6.0 5.0 5.5 6.0 5.0 5.2 5.5 3.5 3.5 3.5 0601 -1200 5.5 5.7 6.0 4.5 4.8 5.0 5.0 5.0 5.0 3.5 3.5 3.5 1201 -1800 6.5 6.5 6.5 5.5 5.8 6.0 5.5 5.5 5.5 4.0 4.2 4.5 -1801 -2400 6.5 6.7 7.0 6.0 6.0 6.0 5.5 5.5 5.5 4.5 4.5 4.5 DAILY VALUE 5.5 6.2 7.0 4.5 5.5 6.0 5.0 5.3 5.5 3.5 3.9 4.5 -0001 -0600 6.0 6.3 6.5 5.5 5.7 6.0 4.5 4.8 5.0 3.5 3.7 4.0 0601 -1200 6.0 6.2 6.5 5.5 5.5 5.5 4.5 4.5 4.5 3.5 3.5 3.5 1201 -1800 7.0 7.5 8.0 5.5 5.5 5.5 5.5 5.5 5.5 4.0 4.3 4.5 1801-2400 7.5 7.7 8.0 5.5 5.5 5.5 4.5 5.2 5.5 4.0 4.3 4.5 ~ DAILY VALUE 6.0 6.9 8.0 5.5 5.5 6.0 4.5 5.0 5.5 3.5 4.0 4.5 0001 -0600 6.5 6.8 7.0 5.5 5.5 5.5 3.0 3.5 4.0 ---0601 -1200 6.5 6.5 6.5 5.5 5.7 6.0 2.5 2.8 3.5 ----- 1201 -1800 7.0 7.5 8.0 7.0 7.3 7.5 4.0 4.5 5.0 --.....--- 1801 -2400 7.0 7.5 8.0 6.5 7.2 7.5 3.5 4.2 4.5 ------- DAILY VALUE 6.5 7.1 8.0 5.5 6.4 7.5 2.5 3.7 5.0 ------------ 0001 -0600 6.5 6.7 7.0 5.5 6.0 6.5 2.0 2.5 3.0 -------------0601 -1200 6.0 6.0 6.0 5.5 5.5 5.5 2.0 2.2 2.5 MONTHLY VALUE 1201 -1800 6.5 6.5 6.5 5.5 5.7 6.0 3.5 4.2 4.5 ,~----------- 1801 -2400 6.5 6.5 6.5 5.0 5.2 5.5 4.5 4.5 4.5 2.0 5.5 8.5 DAILY VALUE 6.0 6.4 7.0 5.0 5.6 6.5 2.0 3.3 4.5 -------------------------------------------------------------------------------- 4-C-74 Table 4-C-22.Thermograph data summary,summer surface water temperature (C), Watana Creek,RM 194.1,Geocode S32N06E25CCA.,.we -------------------------------------------------------------------------------- -JUNE 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 ------------------6.5 7.5 8.5 0601 1200 ~---------------------6.5 7.8 9.5 1201 -1800 ------------------11.0 11.3 11.5 1801 -2400 ----- ---------------10.0 10.8 11.5 DAILY VALUE ------------------------6.5 9.4 11.5 ~~ 0001 -0600 ---------------------7.0 7.7 8.5 0601 -1200 ------------------7.0 8.0 9.0 1201 -1800 ----------------------11.0 11.7 12.0 ~ 1801 -2400 -------------------------10.5 11.3 12.0 DAILY VALUE --------------------------7.0 9.7 12.0 '0001 -0600 -------------------------7.0 8.0 9.0 ~Im:'l, 0601 -1200 ------------------------7.0 8.2 9.5 1201 -1800 ---------------------11.0 12.2 13 .0 1801 -2400 -------------------11.0 12.0 13.0 DAILY VALUE -----------------------,-7.0 10.1 13 .0 0001 -0600 --- ---------------------8.5 9.2 10.0 0601 -1200 ----------------------8.5 9.2 10.0 ~"""l 1201 -1800 ------------------------11.0 11.0 11.0 1801 -2400 ------ - -------6.0 6.5 7.0 9.0 9.7 10.5 DAILY VALUE --------------6.0 ---7.0 8.5 9.7 11.0 ili!II~ 0001 -0600 ------------ ---- 5.0 5.2 5.5 7.5 7.8 8.5 0601 -1200 ------------5.0 5.3 6.0 7.5 7.7 8.0 1201 -1800 ------- -- --------6.5 7.0 7.5 8.5 9.3 10.5 1801 2400 7.0 7.3 7.5 9.5 10.0 10.5 1'''''\----------------- DAILY VALUE -----------------5.0 6.2 7.5 7.5 8.7 10.5 0001 -0600 ------------------5.5 5.7 6.0 7.5 8.3 9.0 0601 -1200 -----------------5.5 6.0 6.5 7.5 7.8 8.0 1201 -1800 ----------------8.0 8.5 9.0 9.0 9.3 9.5 1801 -2400 -----------------8.0 8.3 8.5 9.0 9.2 9.5 DAILY VALUE ------ -----------5.5 7.1 9.0 7.5 8.7 9.5 ~ 0001 -0600 ------ ------------5.5 6.3 7.0 ---------- 0601 -1200 ------ --------- --- 6.0 6.8 8.0 --------- 1201 -1800 ------------------10.0 11.2 12.0 ------ ---- ~ 1801 -2400 ----- -------------9.5 10.8 12.0 ------------ DAILY VALUE --------------------5.5 8.8 12.0 ------------ .....0001 -0600 -------------------6.0 7.0 8.0 --------------0601 ...1200 -------------------6.0 7.2 8.5 MONTHLY VALUE 1201 -1800 ------ --------------11.0 12.2 13.0 --------------1801 -2400 ---------------------10.0 11.3 12.5 5.0 ----13 .0 ~ DAILY VALUE -------- -------------6.0 9.4 13.0 ~, 4-C-76 F"'" ,~~.Table 4-C-22.Cont. ~ -JULY 1982 - ---------------------------------------------------------------------------~~--- TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- ..-0001 -0600 7.5 8.0 8.5 9.5 10.2 11.0 8.0 8.2 8.5 .8.0 8.0 8.0 0601 -1200 7.0 7.2 7.5 9.5 10.2 11.0 8.0 ---8.0 8.0 8.0 8.0 1201 -1800 8.0 8.3 8.5 11.5 11.5 11.5 12.0 ---12.0 8.0 8.5 9.0 F"'"1801 -2400 8.0 8.3 8.5 10.0 10.8 11.5 10.0 10.5 11.0 8.5 8.7 9.0 DAlLY VALUE 7.0 8.0 8.5 9.5 10.7 11.5 8.0 ---12.0 8.0 8.3 9.0 0001 -0600 6.5 7.0 7.5 9.0 9.2 9.5 8.5 8.7 9.0 7.0 7.3 7.5 0601 -1200 6.5 7.5 8.5 9.0 9.3 10.0 8.0 8.3 8.5 7.0 7.7 8.5 1201 -1800 10.0 10.7 11.5 11.0 11.3 11.5 9.0 9.5 10.0 10.0 10.8 11.5 1801 -2400 9.0 10.0 11.0 10.0 10.5 11.0 9.0 9.7 10.5 10.0 10.8 11.5 DAILY VALUE 6.5 8.8 11.5 9.0 10.1 11.5 8.0 9.0 10.5 7.0 9.2 11.5 0001 -0600 6.0 6.8 8.0 8.5 8.8 9.0 6.5 7.2 8.0 8.5 9.0 9.5 0601 -1200 6.0 7.0 8.5 8.5 8.8 9.5 6.5 8.2 10.0 8.5 8.7 9.0 1201 -1800 11.0 12.2 13.0 10.5 10.8 11.0 12.0 13.2 14.0 10.0 10.8 11.5--1801 -2400 10.5 11.5 12.5 10.0 10.5 11.0 11.0 12.3 13 .5 10.0 10.8 11.5 DAILY VALUE 6.0 9.4 13.0 8.5 9.7 11.0 6.5 10.2 14.0 8.5 9.8 11.5 ~/~ll'U~",0001 ...0600 7.0 8.0 9.0 8.5 9.0 9.5 7.5 8.7 10.0 8.0 8.5 9.0 0601 -1200 7.0 8.0 9.0 8~5 8.7 9.0 7.5 8.8 10.5 8.0 8.7 9.5 1201 -1800 10.5 11.2 11.5 9.5 10.0 10.5 12.5 13.3 14.0 10.5 11.5 12.0 1801 -2400 10.0 10.8 11.5 9.5 10.0 10.5 12.5 13 .3 14.0 11.0 11.5 12.0 DAILY VALUE 7.0 9.5 11.5 8.5 9.4 10.5 7.5 11.0 14.0 8.0 10.0 12.0 0001 -0600 7.5 8.2 9.0 8.0 8.5 9.0 9.0 10.0 11.0 9.0 9.5 10.0 0601 -1200 7.5 8.5 9.5 8.0 8.7 9.5 8.5 9.0 9.5 9.0 9.0 9.0-1201-1800 11.0 11.3 11.5 11.0 11.3 11.5 10.0 10.3 10.5 9.1 9.1 9.1 1801 -2400 10.0 10.811.5 10.5 11.0 11.5 10.0 10.3 10.5 8.6 8.9 9.1 DAILY VALUE 7.5 9.7 11.5 8.0 9.9 11.5 8.5 9.9 11.0 8.6 9.1 10.0 0001 -0600 7.5 8.2 9.0 8.5 8.8 9.5 9.0 9.2 9.5 7.1 7.6 8.1 0601 -1200 7.5 8.3 9.5 8.5 8.7 9.0 8.5 8.7 9.0 7.1 7.4 7.6 1201 -1800 11.5 12.2 12 .5 10.0 10.7 11.0 10.0 10.0 10.0 7.6 7.9 8.1 ~1801 -2400 10.5 11.5 12.5 10.0 10.5 11.0 9.0 9.2 9.5 7.6 7.8 8.1 DAILY VALUE 7.5 10.0 12.5 8.5 9.7 11.0 8.5 9.2 10.0 7.1 7.7 8.1 0001 -0600 7.0 8.0 9.0 8.0 8.5 9.0 8.0 8.2 8.5 6.6 6.9 7.1-0601 -1200 7.0 8.5 10.5 8.0 8.7 9.5 8.0 8.0 8.0 6.6 6.9 7.1 1201 -1800 13.0 14.5 15.5 10.5 10.5 10.5 8.5 8.5 8.5 8.1 8.6 9.1 1801 -2400 13.0 14.0 15.0 9.5 9.8 10.0 8.5 8.5 8.5 7.6 8.4 9.1 DAILY VALUE 7.0 11.215.5 8.0 9.4 10.5 8.0 8.3 8.5 6.6 7.7 9.1 0001 -0600 9.5 10.3 11.5 8.0 8.5 9.0 8.0 8.0 8.0 -------------- 0601 -1200 9.5 10.2 11.0 8.0 8.2 8.5 8.0 8.2 8.5 MONTHLY VALUE 1201 -1800 12.5 12.813.0 9.0 9.7 10.0 8.5 8.7 9.0 -------------- 1801 -2400 11.5 12.2 13.0 9.0 9.5 10.0 8.0 8.3 8.5 6.0 9.5 15.5 DAILY VALUE 9.5 11.4 13.0 8.0 9.0 10.0 8.0 8.3 9.0 .--------------------------------------------------------------------------------- 4-C-77 IIl:@:i"ll, Table 4-C-22.Cont. ~" """-AUGUST 1982 - --------------------------------------~-----------------------------------------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX """"-------------------------------------------------------------------------------- 0001 -0600 6.1 6.6 7.1 6.6 6.9 7.1 ------------------ 0601 -1200 6.1 6.8 7.6 6.6 6.8 7.1 ------ ----------- 1201 -1800 8.6 9.4 10.1 8.1 8.4 8.6 ----------------- 1801 -2400 8.1 8.8 9.6 7.6 8.1 8.6 ------------------ DAILY VALUE 6.1 7.9 10.1 6.6 7.6 8.6 ------------------...., 0001 -0600 6.1 6.6 7.1 6.6 6.8 7.1 ---------------- 0601 -1200 6.1 6.9 8.1 6.6 6.9 7.6 ------------------- 1201 -1800 8.6 9.1 9.6 7.6 7.9 8.1 ----- ---------------~. 1801 -2400 8.1 8.9 9.6 7.1 7.6 8.1 ------------------ DAILY VALUE 6.1 7.9 9.6 6.6 7.3 8.1 -------------------'-- 0001 -0600 5.6 6.3 7.1 6.1 6.6 7.1 ------ --------_.---- 0601 -1200 5.6 6.8 8.1 6.1 6.6 7.1 ------------------ 1201 -1800 9.6 10.4 11.1 8.6 8.9 9.1 -------------------- 1801 -2400 8.6 9.6 10.6 7.6 8.4 9.1 ------------------ DAILY VALUE 5.6 8.3 11.1 6.1 7.6 9.1 --------------------- 0001 -0600 6.1 6.8 7.6 5.1 5.8 6.6 -------------------- 0601 -1200 5.6 6.8 8.1 4.6 5.8 7.1 ----- ------------- 1201 1800 10.1 10.8 11.1 9.1 10.1 10.6 -----------~-------- 1801 -2400 9.1 9.8 10.6 8.6 9.4 10.6 --------------- DAILY VALUE 5.6 8.5 11.1 4.6 7.8 10.6 -------------------- 0001 -0600 6.6 7.3 8.1 6.1 6.8 7.6 ---------------- 0601 -1200 6.6 7.4 8.6 6.1 6.9 8.1 --------------------- 1201 -1800 9.1 10.1 10.6 10.1 11.1 11.6 -------------- 1801 -2400 8.6 9.3 10.1 10.6 11.1 11.6 ---------------- DAILY VALUE 6.6 8.5 10.6 6.1 9.0 11.6 ------------------ 0001 -0600 6.1 6.9 7.6 8.6 9.1 9.6 ----------------- 0601 -1200 6.1 7.3 8.6 8.6 8.6 8.6 ---------------- 1201 -1800 9.6 9.9 10.1 8.6 9.1 9.6 ---------------- 1801 -2400 8.6 9.4 10.1 8.6 9.1 9.6 --------------- DAILY VALUE 6.1 8.4 10.1 8.6 9.0 9.6 -------------------~ 0001 -0600 6.6 7.1 7.6 7.1 7.6 8.1 ------------------- 0601 -1200 6.1 6.9 8.1 7.1 7.3 7.6 -------------------- 1201 -1800 8.6 8.9 9.1 8.1 8.1 8.1 ---------------------~ 1801 -2400 8.1 8.6 9.1 ------------------------------- DAILY VALUE 6.1 7.9 9.1 7.1 ---8.1 ------------------- 0001 -0600 6.6 7.1 7.6 --------------------------------- 0601 -1200 6.6 7.1 7.6 ----------------------MONTHLY VALUE 1201 -1800 8.6 8.6 8.6 ------------------ ------------------- 1801 -2400 7.6 8.1 8.6 --------------------4.6 --11.6 -DAILY VALUE 6.6 7.7 8.6 ---------------------- -------------------------------------------------------------------------------- 4-C-78 --4-c-79 - """Table 4-C-22.Cont. ,4'. -OCTOBER 1982 - --------------------------------------------------------------------------------TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ~ -------------------------------------------------------------------------------- 0001 -0600 2.0 2.3 2.5 .5 .5 .5 ---------------- 0601 -1200 2.0 2.2 2.5 .5 .5 .5 -----------------""" 1201 -1800 3.0 3.0 3.0 1.0 1.0 1.0 ---------------- 1801 -2400 2.5 2.8 3.0 1.0 1.0 1.0 ---------------- DAILY VALUE 2.0 2.5 3.0 .5 .7 1.0 ------------------- 0001 -0600 2.0 2.3 2.5 .5 .7 1.0 --------------- 0601 -1200 2.0 2.2 2.5 .5 .5 .5 ------------------ 1201 -1800 3.0 3.0 3.0 1.0 1.0 1.0 ----------_......--1801 -2400 2.5 2.8 3.0 .5 .7 1.0 ---------------- DAILY VALUE 2.0 2.6 3.0 .5 .7 1.0 ------------------ 0001 -0600 2.0 2.2 2.5 .5 .5 .5 ---------------~ 0601 -1200 2.0 2.2 2.5 .5 .5 .5 ------------------ 1201 -1800 2.5 2.7 3.0 .5 .5 .5 -------------------1801 -2400 2.5 2.7 3.0 .5 .5 .5 -------------- ---- DAlLY VALUE 2.0 2.4 3.0 .5 .5 .5 ~--------------------- 0001 -0600 1.5 1.8 2.0 .5 .5 .5 ------------------ 0601 -1200 1.5 1.5 1.5 .5 .5 .5 -------------------~.-1201 -1800 1.5 1.8 2.0 .5 1.0 1.5 ----_..----------- 1801 -2400 2.0 2.0 2.0 1.5 1.5 1.5 ------------- --- DAILY VALUE 1.5 1.8 2.0 .5 .9 1.5 ------------------ ~, 0001 -0600 1.5 1.5 1.5 .5 .8 1.0 ------------------- 0601 -1200 1.5 1.5 1.5 .5 .5 .5 ------------------- 1201 -1800 1.5 1.5 1.5 .5 .5 .5 ------------------- 1801 -2400 1.0 1.2 1.5 .5 .5 .5 -----------------DAILY VALUE 1.0 1.4 1.5 .5 .6 1.0 -------------------- 0001 -0600 .5 .5 .5 .5 .5 .5 ------------------0601 -1200 .5 .5 .5 .5 .5 .5 ----------------...--- 1201 -1800 2.0 2.0 2.0 .5 .5 .5 -------------------- 1801 -2400 .5 1.0 2.0 .5 .5 .5 ---------------- DAlLY VALUE .5 1.0 2.0 .5 .5 .5 -----------------~ 0001 -0600 .5 .5 .5 .5 .5 .5 ---------------- ---- 0601 -1200 .5 .5 .5 .5 .5 .5 -------------------- 1201 -1800 .5 1.5 2.0 .5 .5 .5 -------------------1801 -2400 .5 1.0 2.0 .5 .5 .5 -------------------- DAlLY VALUE .5 .9 2.0 .5 .5 .5 ------------------- ---- 0001 0600 .5 .5 .5 .5 .5 .5 ---------------~------------ 0601 -1200 .5 .5 .5 .5 .5 .5 -----------MONTIlLY VALUE 1201 -1800 .5 .8 1.0 -----_....._-----------------------'- 1801 -2400 .5 .8 1.0 ------------------.5 ---3.0 DAILY VALUE .5 .7 1.0 .5 --.5 -------- -------------------------------------------------------------------------------- 4-C-80 - Table4-C-23.Thermograph data summary,summer surface water temperature (C), Kosina Creek,RM 206.8,Geocode S31N08E15BAB. -JUNE 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 11 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 0001 0601 1201 1801 DAlLY 0600 1200 1800 2400 VALUE 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE 0600 1200 1800 0600 1200 1800 0600 1200 1800 0600 1200 1800 11.0 11.0 12.0 13.3 14.5 12.5 13.1 14.5 11.0 14.5 10.0 10.8 11.5 9.5 9.8 10.5 11.5 12.0 12.5 10.5 11.0 11.5 9.5 10.9 12.5 8.5 9.0 9.5 8.5 8.5 8.5 9.5 10.0 10.5 10.5 10.5 10.5 8.5 9.5 10.5 1.5 8.3 9.5 ----1.0 7.0 7.0 6.5 6.8 7.0 7.5 8.5 9.5 6.5 7.7 9.5 0001 0601 1201 1801 2400 DAILY VALUE 0001 0601 1201 1801 2400 DAILY VALUE 0001 0601 1201 1801 2400 DAILY VALUE 0001 0601 1201 1801 2400 DAILY VALUE - -- 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE 0600 1200 1800 0001. 0601 1201 1801 2400 DAILY VALUE MONTHLY VALUE 6.5 ---14.5 -~----------------------_._----------------------------------------------------- 4-C-81 -Table 4-C-23.Cont. -JULY 1982 - -------------------------------------------------------------------------------- TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 "':"0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAlLY VALUE 8.5 9.0 9.5 8.5 8.5 8.5 8.5 9.0,9.5 9.0 9.3 9.5 8.5 9.0 9.5 8.0 8.5 9.0 8.0 8.7 9.5 10.0 10.7 11.0 10.5 10.8 11.0 8.0 9.7 11.0 7.5 8.5 9.5 7.0 8.2 9.5 11.0 12.3 13.5 13 .0 13.3 13.5 7.0 10.6 13.5 9.5 10.5 11.5 9.5 10.2 11.0 12.0 12.7 13.0 12.5 12.8 13.0 9.5 11.513.0 9.5 10.5 11.5 9.0 9.5 10.0 11.0 12.2 13.0 12.0 12.5 13.0 9.0 11.2 13.0 9.5 10.2 11.0 9.5 10.2 11.0 12.0 12.8 13.5 12.5 13.0 13.5 9.5 11.5 13.5 9.5 10.3 11.5 9.0 10.2 1l.5 13.5 14.5 15.5 15.5 15.816.0 9 .0 12.7 16.0 11.0 11.5 12.0 10.5 10.7 11.0 11.5 12.0 12.5 12.0 12.3 12.5 10.5 11.6 12.5 11.5 11.7 12.0 11.0 11.0 11.0 11.5 11.5 11.5 11.0 11.2 11.5 11.0 11.3 12.0 9.5 10.0 10.5 9.5 9.7 10.0 10.5 11.0 11.5 11.0 11.2 11.5 9.5 10.5 11.5 10.5 10.5 10.5 10.0 10.2 10.5 11.0 11.3 11.5 11.0 11.3 11.5 10.0 10.8 11.5 10.0 10.2 10.5 9.5 10.0 10.5 11.0 11.8 12.5 12.0 12.3 12.5 9.5 11.1 12.5 10.0 10.7 11.5 10.0 10.2 10.5 10.5 10.7 1l.0 11.5 11.812.0 10.0 10.8 12.0 10.0 10.5 11.0 10.0 10.0 10.0 10.5 10.8 11.0 11.0 11.0 11.0 10.0 10.6 11.0 9.0 9.5 10.0 9.0 9.3 10.0 10.5 11.0 11.5 12.0 12.0 12.0 9.0 10.5 12.0 10.5 11.0 11.5 10.0 10.0 10.0 11.0 11.3 11.5 11.5 11.812.0 10.0 11.0 12.0 9.5 10.3 11.0 9.5 10.3 11.5 13.0 14.3 15.5 15.0 15.7 16.0 9.5 12.7 16.0 11.5 12.5 13.5 11.0 11.8 13.0 14.0 15.0 16.0 15.0 15.5 16.0 11.0 13.7 16.0 11.5 12.5 13.5 11.5 11.812.5 13.0 13.3 13.5 13.0 13.3 13.5 11.5 12.7 13.5 11.5 11.7 12.0 11.0 11.2 11.5 12.0 12.3 12.5 12.0 12.3 12.5 11.0 11.9 12.5 11.0 11.2 11.5 10.5 10.7 11.0 11.0 11.5 12.0 11.5 11.8 12.0 10.5 11.3 12.0 10.5 11.0 11.5 10.5 10.5 10.5 11.0 11.5 12.0 12.0 12.3 12.5 10.5 11.3 12.5 10.0 10.7 11.5 10.0 10.5 11.0 13.5 13.7 14.0 13.5 13.814.0 10.0 12.2 14.0 11.5 11.812.5 11.5 11.812.5 13.5 14.5 15.0 14.0 14.5 15.0 11.5 13.2 15.0 12.0 12.7 13.5 11.5 12.0 12.5 14.0 14.7 15.0 14.0 14.5 15.0 11.5 13.5 15.0 12.0 12.7 13.5 12.0 12.2 12.5 12.5 12.5 12.5 12.0 12.3 12.5 12.0 12.4 13.5 11.0 11.3 11.5 11.0 11.0 11.0 11.0 11.3 11.5 11.0 11.3 11.5 11.0 11.2 11.5 9.5 10.0 10.5 9.5 9.8 10.5 11.5 11.8 12.0 11.5 11.8 12.0 9.5 10.9 12.0 0001 -0600 12.5 13.3 14.5 0601 -1200 12.0 12.2 12.5 1201 -1800 13.0 13.5 14.5 1801 -2400 13.0 13.8 14.5 DAILY VALUE 12.0 13.2 14.5 10.0 10.2 10.5 9.5 9.7 10.0 10.0 10.7 11.0 10.5 10.8 11.0 9.5 10.3 11.0 11.0 11.2 11.5 --------------- 11.0 11.2 11.5 MONTHLY VALUE 12.0 12.0 12.0 --------------- 11.5 11.8 12.0 7.0 11.5 16.0 11.0 11.5 12.0 4-C-82 - - Table 4-C-23.Cont. 4-C-83 4-C-84 !""" Table 4-C-23 .Cont.-- -OCTOBER 1982 - ---------------------------------------------------------------------------~--~-TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31.-PERIOD ~IIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAXu_________________________________________________________-----______________ 0001 -0600 1.6 1.9 2.1 .1 .1 .1 ------------------- 0601 -1200 1.6 1.6 1.6 .1 .1 .1 ------------------ 1201 -1800 2.1 2.3 2.6 .1 .1 .1 -------------------- 1801 -2400 2.6 2.6 2.6 .1 .1 .1 --------------------- DAILY VALUE 1.6 2.1 2.6 .1 .1 .1 ------------------- 0001 -0600 2.1 2.3 2.6 .1 .1 .1 -------------------- 0601 -1200 1.6 1.9 2.1 .1 .1 .1 ----------------- 1201 -1800 2.1 2.4 2.6 .1 .1 .1 -------------------- 1801 -2400 2.6 2.6 2.6 .1 .1 .1 --------------------- DAILY VALUE 1.6 2.3 2.6 .1 .1 .1 -------------------_._-- 0001 -0600 2.1 2.1 2.1 .1 .1 .1 ----------------- 0601 -1200 1.6 1.6 1.6 .1 .1 .1 -------------------- 1201 -1800 1.6 1.9 2.1 .1 .1 .1 ------------------- 1801 -2400 2.1 2.1 2.1 .1 .1 .1 '----- -----------~---F DAILY VALUE 1.6 1.9 2.1 .1 .1 .1 --------------------- 0001 -0600 1.1 1.4 1.6 .1 .1 .1 --------------------- ~,~,0601 -1200 1.1 1.1 1.1 .1 .1 .1 ---------- ----------- 1201 -1800 1.1 1.4 1.6 .1 .1 .1 --------------------- 1801 -2400 1.6 1.6 1.6 .1 .1 .1 -------------------- DAlLY VALUE 1.1 1.4 1.6 .1 .1 .1 ------------------ 0001 -0600 1.1 1.3 1.6 .1 .1 .1 --------------------- 0601 -1200 .6 .9 1.1 .1 .1 .1 --------------------- 1201 -1800 1.1 1.1 1.1 .1 .1 .1 ---------------------....1801 2400 1.1 1.1 1.1 .1 .1 .1--------------------- DAILY VALUE .6 1.1 1.6 .1 .1 .1 ----------------_.- .....0001 -0600 .6 .8 1.1 .1 .1 .1 -------------------- 0601 -1200 .1 .1 .1 .1 .1 .1 -------------------- 1201 -1800 .6 .6 .6 .1 .1 .1 --------------------- 1801 -2400 .6 .6 .6 .1 .1 .1 --------------------- DAlLY VALUE .1 .5 1.1 .1 .1 .1 ---------------------- 0001 -0600 .1 .4 .6 .1 .1 .1 ---------------------- 0601 -1200 .1 .1 .1 .1 .1 .1 ------------------- 1201 -1800 .1 .4 .6 .1 .1 .1 ----------------- ---- 1801 -2400 .1 .3 .6 .1 .1 .1 ---------------------- DAlLY VALUE .1 .3 .6 .1 .1 .1 ----------------------- ~0001 0600 .1 .1 .1 .1 .1-.1 -------------------------0601 -1200 .1 .1 .1 .1 .1 .1 -----------MONTHLY VALUE 1201 -1800 .1 .1 .1 ---------------------------------------1801 -2400 .1 .1 .1 ----------------------.1 ----2.6 DAILY VALUE .1 .1 .1 .1 ---.1 ----..._----- -------------------------------------------------------------------------------- 4-C-85 Table 4-C-24.Thermograph data summary,summer surface water temperature (C), Goose Creek,RM 231.3,Geocode S30N11E32DBC. -JUNE 1982 - -------------------------------------------------------------------------------- TIME PERIOD DAYS 1 - 8 MIN MEAN -MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX -------------------------------------------------------------------------------- MONTHLY VALUE 8.5 ---15.0 13.5 14.3 15.0 12.5 13.5 14.5 12.5 15.0 10.5 11.0 11.5 10.0 10.8 12.0 13.0 13.3 13.5 10.5 11.5 12.5 10.0 11.7 13.5 9.0 9.5 8.8 9.5 11.812.5 11.8 12.5 10.4 12.5 9.8 10.5 9.7 10.0 11.5 11.5 10.0 10.8 11.5 9.5 10.5 11.5 9.5 9.5 11.5 8.5 8.5 11.0 11.0 8.5 .--- 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001--0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 -1201 1800 1801 2400 DAILY VALUE -------------------------------------------------------------------------------- 4-C-86 ""'1 I I F I " Table 4-C-24.Cont. -JULY 1982 - -------------------------------------------------------------------~----------- - - TIME PERIOD 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE DAYS 1 - 8 MIN MEAN MAX 8.5 8.8 9.5 8.5 9.0 9.5 10.0 10.7 11.0 9.5 10.0 10.5 8.5 9.6 11.0 7.5 8.0 8.5 7.5 8.7 10.0 11.0 12.0 12.5 10.0 11.0 12.0 7.5 9.9 12.5 7.0 7.7 8.5 7.0 8.0 9.5 11.5 13.0 14.0 11.5 12.5 13.5' 7.0 10.3 14.0 9.0 9.7 10.5 9.0 10.0 11.0 13.0 13.3 13.5 11.5 12.3 13.0 9.0 11.3 13.5 9.0 9.5 10.0 8.5 9.7 11.0 12.0 12.7 13.5 11.5 12.2 13'.0 8.5 11.0 13.5 9.5 10.0 10.5 9.5 10.7 12.0 13.0 14.5 15.5 12.5 13.8 15.0 9.5 12.2 15.5 9.5 10.2 11.0 9.5 11.0 13.0 15.0 16.0 16.5 15.0 15.8 16.5 9.5 13.2 16.5 DAYS 9 -16 MIN MEAN MAX 11.5 12.0 12.5 11.5 11.7 12.0 12.5 12.8 13.0 12.0 12.5 13.0 11.512.213.0 11.5 11.7 12.0 11.5 11.5 11.5 12.0 12.0 12.0 11.0 11.5 12.0 11.0 11.7 12.0 10.0 10.3 10.5 10.0 10.2 10.5 11.5 12.3 13.0 12.0 12.5 13.0 10.0 11.3 13.0 10.5 11.0 11.5 10.5 10.5 10.5 11.5 12.5 13.5 12.0 12.7 13.5 10.5 11.7 13.5 10.5 10.7 11.0 10.0 10.7 11.5 13.0 13.0 13.0 11.5 12.2 13.0 10.0 11.6 13.0 9.5 10.2 11.0 9.5 10.2 11.0 12.5 12.8 13.0 11.5 12.0 12.5 9,.5 11.3 13.0 10.0 10.5 11.0 10.0 10.0 10.0 10.5 11.2 11.5 10.5 11.0 11.5 10.0 10.7 11.5 DAYS 17 -24 MIN MEAN MAX. 8.5 9.0 9.5 8.5 8.8 9.5 10.5 11.0 11.5 10.5 10.8 11.0 8.5 9.9 11.5 9.5 9.7 10.0 9.5 9.7 10.0 11.0 11.8 12.5 11.5 12.2 12.5 9.5 10.8 12.5 9.0 9.8 10.5 9.0 10.2 11.5 14.0 15.0 15.5 13.0 14.3 15.5 9.0 12.3 15.5 9.5 10.5 11.5 9.5 10.8 12.5 14.5 15.3 16.0 13.5 14.7 15.5 9.5 12.8 16.0 11.0 11.7 12.5 11.0 11.7 12.5 14.0 14.0 14.0 12.0 13.0 14.0 11.0 12.6 14.0 10.5 11.0 11.5 10.5 11.0 11.5 12.5 12.8 13.0 11.5 12.0 12.5 10.5 11.7 13.0 10.5 10.7 11.0 10.5 10.5 10.5 11.5 12.0 12.5 11.5 12.0 12.5 10.5 11.3 12.5 DAYS 25 -31 MIN MEAN MAX. 10.5 10.8 11.0 10.5 10.5 10.5 11.0 12.5 13.5 12.0 12.5 13.0 10.5 11.6 13.5 9.0 9.7 10.5 9.0 10.2 11.5 13.5 14.5 15.0 13.0 14.0 15.0 9.0 12.1 15.0 10.5 11.2 12.0 10.5 11.7 13.0 14.5 15.7 16.5 13.5 14.5 15.5 10.5 13.2 16.5 11.5 12.3 13.0 11.0 11.813.0 14.0 15.2 16.0 13.5 14.5 15.5 11.0 13.5 16.0 12.0 12.5 13.0 12.0 12.2 12.5 13.0 13.2 13.5 12.5 13.2 13.5 12.0 12.7 13.5 10.5 11.0 11.5 10.5 11.0 11.5 12.0 12.0 12.0 11.0 11.5 12.0 10.5 11.4 12.0 10.0 10.0 10.0 10.0 10.3 11.0 12.5 13.0 13.5 11.0 11.7 12.5 10.0 11.2 13.5 r'fllW<l. 0001 -0600 12.0 12.7 13.5 0601 -1200 12.0 12.3 13.0 1201 -1800 15.0 15.3 15.5 1801 -2400 13.0 13.8 14.5 DAILY VALUE 12.0 13.5 15.5 9.0 9.5 10.0 9.0 9.2 9.5 10.0 10.7 11.0 10.0 10.3 10.5 9.0 9.9 11.0 4-C-87 10.5 10.8 11.0 --------------- 10.5 11.2 12.0 MONTHLY VALUE 12.5 12.8 13.0 --------------- 11.5 12.0 12.5 7.0 11.6 16.5 10.5 11.7 13.0 Table 4-C-24.Coot. ","ii," -AUGUST 1982 -~ I,--------------------------------------------------------------------------------! TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX .....-------------------------------------------------------------------------------- 0001 -0600 9.5 10.0 10.5 8.5 9.3 10.0 9.0 9.3 10.0 9.5 10.0 10.5 0601 -1200 9.5 10.3 11.0 9.0 9.7 10.5 9.0 9.5 10.0 9.5 10.2 11.0 ~ 1201 -1800 12.0 12.0 12.0 11.0 11.7 12.0 10.5 10.7 11.0 12.0 12.3 12.5 1801 -2400 10.5 11.2 12.0 10.5 11.2 12.0 9.0 '9.8 10.5 10.0 11.0 12.0 DAILY VALUE 9.5 10.9 12.0 8.5 10.5 12.0 9.0 9.8 11.0 9.5 10.9 12.5 0001 -0600 8.5 9.2 10.0 9.5 9.7 10.0 7.0 7.7 8.5 8.0 8.5 9.0 0601 -1200 8.5 10.2 12.0 9.5 10.2 11.0 7.0 8.7 10.5 8.5 9.2 10.0 1201 -1800 12.5 13 .0 13.5 11.5 11.7 12.0 12.0 12.3 12.5 11.0 11.0 11.0 1801 -2400 11.0 12.0 13.0 10.0 10.7 11.5 11.0 11.5 12.0 9.0 9.8 10.5 Il!IOj DAILY VALUE 8.5 11.1 13 .5 9.5 10.5 12.0 7.0 10.0 12.5 8.0 9.6 11.0 ! 0001 -0600 9.5 9.8 10.5 9.0 9.3 9.5 9.0 9.5 10.0 8.0 8.5 9.0 0601 -1200 9.5 10.8 12.5 9.0 9.5 10.0 9.0 10.0 11.5 7.5 8.8 10.5 1201-1800 13 .5 14.2 14.5 11.5 11.8 12.0 13.0 13.0 13.0 12.0 12.0 12.0 1801 -2400 12.0 12.7 13.5 10.0 11.0 12.0 10.5 11.5 12.5 9.5 10.5 11.5 DAILY VALUE 9.5 11.9 14.5 9.0 10.4 12.0 9.0 11.0 13.0 7.5 10.0 12.0 ... 0001 -0600 9.5 10.2 11.0 7.5 8.3 9.0 9.5 9.7 10.0 7~0 7.7 8.5 0601 -1200 9.5 11.2 13.0 7.5 9.2 11.0 9.5 10.2 11.0 7.0 8.2 9.5 1201 -1800 14.0 14.5 15.0 13.0 13.8 14.5 12.5 13.2 13.5 11.0 11.0 11.0 -1801 -2400 13.0 13 .7 14.5 11.5 12.5 13.5 11.5 12.0 12.5 9.5 10.0 10.5 DAILY VALUE 9.5 12.4 15.0 7.5 11.0 14.5 9.5 11.2 13.5 7.0 9.2 11.0 0001 -0600 10.0 10.7 11.5 9.0 9.7 10.5 10.5 10.7 11.0 8.0 8.2 8.5 0601 -1200 10.5 11.7 13 .0 9.0 10.7 12.5 10.0 10.7 11.5 8.0 8.0 8.0 1201 -1800 14.0 14.3 14.5 14.5 15.2 15.5 13 .0 13.3 13 .5 8.5 8.8 9.0 1801 -2400 12.5 13.2 14.0 12.5 13.5 14.5 12.0 12.5 13.0 9.0 9.0 9.0 DAlLY VALUE 10.0 12.5 14.5 9.0 12.2 15.5 10.0 11.813.5 8.0 8.5 9.0 0001 -0600 9.5 10.7 12.0 10.5 11.2 12.0 10.0 10.811.5 8.0 8.3 8.5 0601 -1200 9.5 10.7 11.5 10.5 11.7 13 .0 9.5 10.7 12.0 8.0 8.3 8.5 1201 -1800 13.5 14.3 15.0 13.5 13.5 13.5 14.0 14.0 14.0 9.0 9.0 9.0 1801 -2400 12.0 13.0 14.0 12.0 12.8 13.5 12.0 12.7 13 .5 8.0 8.5 9.0 DAILY VALUE 9.5 12.2 15.0 10.5 12.3 13 .5 9.5 12.0 14.0 8.0 8.5 9.0 0001 -0600 10.5 11.0 11.5 10.5 10.8 11.5 11.0 11.5 12.0 7.5 7.8 8.0 0601 -1200 10.5 11.3 12.5 10.0 10.5 1i.0 11.0 11.3 12.0 7.5 8.0 8.5 1201 -1800 12.5 12.5 12.5 11.5 11.7 12.0 13 .0 13.2 13.5 10.0 10.0 10.0 1801 -2400 11.0 11.5 12.0 10.0 10.5 11.0 11.5 12.0 12.5 8.0 8.5 9.0 DAILY VALUE 10.5 11.6 12.5 10.0 10.9 12.0 11.0 12.0 13.5 7.5 8.6 10.0 0001 -0600 10.0 10.2 10.5 8.0 8.5 9.0 10.5 10.8 11.5 ---------------~ 0601 -1200 10.0 10.5 11.0 8.0 9.5 11.0 10.5 11.0 11.5 MONTHLY VALUE 1201 -1800 11.5 11.812.0 12.5 12.5 12.5 12.0 12.5 13.0 ------....-------- 1801-2400 10.5 11.2 12 .0 10.0 10.7 11 .5 11.0 11.5 12.0 7.0 10.815.5 DAILY VALUE 10.0 10.9 12.0 8.0 10.3 '12.5 10.5 11.5 13.0 -, -------------------------------------------------------------------------------- 4-C--88 .- ~ .-Table 4-C-24.Cant • F -SEPTEMBER 1982 - -----------------------------------------------_.~---------------------~--~------ ~TIME DAYS 1 - 8 DAYl?9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX.MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 7.0 7.5 8.0 6.5 6.7 1.0 5.5 5.7 6.0 3.5 3.7 4.0 0601 -1200 7.0 7.7 8.5 6.5 6.5 6.5 5.5 5.7 6.0 3.0 3.3 4.0 1201 ..1800 9.5 9.7 10.0 7.0 7.2 7.5 7.0 7.3 7.5 5.0 5.3 5.5 1801 -2400 7.5 8.3 9.0 6.5 6.8 7.0 6.0 6.5 7.0 4.5 5.0 5.5 DAILY VALUE 7.0 8.3 10.0 6.5 6.8 7.5 5.5 6.3 7.5 3.0 4.3 5.5 0001 -0600 6.5 6.7 7.0 5.5 5.7 6.0 5.5 5.7 6.0 3.5 3.8 4.5 0601 -1200 6.5 7.3 8.5 5.5 5.7 6.0 5.0 5.5 6.0 3.5 3.7 4.0,..... 1201 -1800 9.0 9.3 9.5 6.5 7.2 7.5 6.5 6.8 7.0 4.5 4.8 5.0 1801 -2400 8.0 8.5 9.0 6.5 6.7 7.0 6.0 6.3 6.5 4.5 4.5 4.5 DAILY VALUE 6.5 8.0 9.5 5.5 6.3 7.5 5.0 6.1 7.0 3.5 4.2 5.0 0001 -0600 7.0 7.2 7.5 4.5 5.2 5.5 5.5 5.5 5.5 3.5 3.7 4.0 0601 -1200 7.0 7.2 7.5 4.5 5.3 6.0 5.5 5.7 6.0 3.5 3.7 4.0 1201 -1800 8.0 8.0 8.0 6.5 6.7 7.0 6.5 6.7 7.0 5.0 5.3 6.0-1801 -2400 7.0 7.5 8.0 4.0 4.5 5.5 6.0 6.5 7.0 3.0 3.8 4.5 DAILY VALUE 7.0 7.5 8.0 4.0 5.4 7.0 5.5 6.1 7.0 3.0 4.1 6.0 0001 -0600 6.0 6.5 7.0 3.5 3.7 4.0 4.5 5.0 5.5 1.0 1.7 2.0 0601 -1200 5.5 6.2 7.0 3.0 3.7 4.5 4.5 4.8 5.5 1.0 1.5 2.0 1201 -1800 7.5 7.8 8.0 5.5 5 ..7 6.0 6.0 6.3 6.5 2.5 2.5 2.5 1801 -2400 6.5 7.3 8.0 5.5 5.7 6.0 5.5 6.0 6.5 2.0 2.0 2.0 DAlLY VALUE 5.5 7.0 8.0 3.0 4.7 6.0 4.5 5.5 6.5 1.0 1.9 2.5 0001 -0600 5.5 5.8 6.0 5.0 5.0 5.0 4.5 5.0 5.5 2.0 2.0 2.0 0601 -1200 5.5 6.0 6.5 4.5 4.5 4.5 4.5 4.8 5.5 2.0 2.2 2.5,...1201-1800 8.0 8.3 '8.5 5.5 5.7 6.0 6.5 6.5 6.5 3.0 3.0 3.0 1801 -2400 7.0 7.5 8.0 5.5 5.5 5.5 5.5 6.2 6.5 2.0 2.0 2.0 DAILY VALUE 5.5 6.9 8.5 4~5 5.2 6.0 4.5 5.6 6.5 2.0 2.3 3.0 0001 -0600 6.0 6.7 7.0 5.0 5.3 5.5 4.5 4.7 5.0 1.5 1.8 2.0 0601 -1200 6.0 6.5 7.5 5.0 5.5 6.0 4.5 4.7 5.0 1.0 1.5 2.0 1201 -1800 8.0 8.5 9.0 6.5 6.5 6.5 6.0 6.0 6.0 2.5 3.0 3.5 1801 -2400 8.0 8.3 8.5 6.0 6.3 6.5 5.0 5.3 5.5 2.5 2.8 3.0-DAlLY VALUE 6.0 7.5 9.0 5.0 5.9 6.5 4.5 5.2 6.0 1.0 2.3 3.5I I 0001 -0600 7.0 7.5 8roO 5.5 5.7 6.0 3.5 4.0 4.5 ----------- ""'"0601 -1200 7.0 7.3 7.5 5.5 6.0 7.0 3.5 3.8 4.5 ----------- 1201 -1800 8.0 8.0 8.0 8.5 8.8 9.0 5.5 5.5 5.5 ----------- 1801 -2400 7.5 7.8 8.0 7.5 8.0 8.5 3.5 4.5 5.5 ------------ DAILY VALUE 7.0 7.7 8.0 5.5 7.1 9.0 3.5 4.5 5.5 ------------ 0001 -0600 7.0 7.2 7.5 6.0 6.5 7.0 1.5 2.0 2.5 -------------- 0601 -1200 7.0 7.0 7.0 6.0 6.2 6.5 1.5 2.0 3.0 MONTHLY VALUE 1201 -1800 7.0 7.3 7.5 7.5 7.5 7.5 4.0 4.3 4.5 --------------......1801 -2400 7.0 7.0 7.0 6.5 6.7 7.0 4.0 4.3 4.5 1.0 5.7 10.0 DAlLY VALUE 7.0 7.1 7.5 6.0 6.7 7.5 1.5 3.2 4.5 !-~';. -------------------------------~------------------------------------------------ 4-C-89 Table 4-C-24.Cant. ~> -OCTOBER 1982 ~- -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ~ -------------------------------------------------------------------------------- 0001 -0600 1.0 1.5 2.0 0.0 0.0 0.0 -------------------- 0601 -1200 1.0 1.3 2.0 .5 .5 .5 ---------------~ 1201 -1800 2.5 2.8 3.0 1.0 1.0 1.0 ------------------- 1801 -2400 2.5 2.7 3.0 1.0 1.0 1.0 ----------------- DAILY VALUE 1.0 2.1 3.0 0.0 .6 1.0 ------------------ ~ 0001 -0600 2.0 2.0 2.0 .5 .7 1.0 ----------------- 0601 -1200 2.0 2.0 2.0 .5 .5 .5 --- ------------------ 1201 -1800 3.0 3.0 3.0 1.0 1.0 1.0 --------------- 1801 2400 2.5 2.8 3.0 .5 .5 .5 -------------------- DAILY VALUE 2.0 2.5 3.0 .5 .7 1.0 ---------------------- 0001 -0600 1.5 1.8 2.0 .5 .5 .5 -----------------------0601 -1200 1.5 1.7 2.0 .5 .5 .5 -------------------- 1201 -1800 2.5 2.5 2.5 .5 .5 .5 ---------------------- 1801 -2400 1.5 1.8 2.0 .5 .5 .5 ----------------- ---- DAILY VALUE 1.5 2.0 2.5 .5 .5 .5 ----------------------- 0001 -0600 1.0 1.0 1.0 .5 .5 .5 --------------------- 0601 -1200 .5 .8 1.0 .5 .5 .5 ------------------ 1201 -1800 2.0 2.0 2.0 .5 .5 .5 ---------------------_.- 1801 -2400 1.5 1.7 2.0 .5 .5 .5 ------------------- DAILY VALUE .5 1.4 2.0 .5 .5 .5 ----------------- 0001 -0600 1.0 1.0 1.0 .5 .5 .5 ---------------- 0601 -1200 .5 .8 1.0 .5 .5 .5 ------------------ 1201 -1800 1.5 1.5 1.5 .5 .5 .5 --------------------- 1801 -2400 1.0 1.2 1.5 .5 .5 .5 ---------------- DAILY VALUE .5 1.1 1.5 .5 .5 .5 ------------------- 0001 -0600 .5 .5 .5 .5 .5 .5 ------------------- 0601 -1200 .5 .7 1.0 .5 .5 .5 ------------------ 1201 -1800 1.0 1.3 1.5 .5 .5 .5 --------------------- 1801 -2400 1.0 1.2 1.5 .5 .5 .5 --------------------- DAILY VALUE .5 .9 1.5 .5 .5 .5 ------ --------------- 0001 -0600 .5 .8 1.0 .5 .5 .5 ------------------- 0601 -1200 .5 .5 .5 .5 .5 .5 ------------------ 1201 -1800 .5 .8 1.0 .5 .5 .5 ------------------ 1801 -2400 .5 .7 1.0 .5 .5 .5 --------------------- DAILY VALUE .5 .7 1.0 .5 .5 .5 ---------------------- 0001 -0600 .5 .5 .5 .5 .5 .5 ------------------------~ 0601 -1200 .5 .5 .5 .5 .5 .5 -----------MONTHLY VALUE 1201 -1800 .5 .8 1.0 --------------------------------- 1801 -2400 0.0 .3 .5 --------------------0.0 ---3.0 DAILY VALUE 0.0 .5 1.0 .5 ---.5 ---------- -------------------------------------------------------------------------------- ~ 4-C·-90 ....., Table 4-C-25.Thermograph data summary,summer surface water temperature (C), Oshetna River,RM 233.4,Geocode S30N11E34CCD • ---~--------------------------------------------------------------------------- -JUNE 1982 --TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 0001 0601 1201 0600 1200 1800 1801 2400 DAILY VALUE 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE 0600 1200 1800.-. 0001 0601 1201 1801 2400 DAILY VALUE ___I 10.3 11.6 12.8 12.8 12.8 12.8 10.3 12.8 0001 0600 .---- 0601 1200 1201 1800 1801 2400 DAILY VALUE 9.8 10.8 11.8 9.3 9.5 9.8 10.8 11.1 11.3 10.3 10.8 11.3 9.3 10.5 11.8 0600 1200 1800 9.8 8.8 9.3 8.5 8.8 8.3 9.3 10.1 10.8 10.8 10.8 10.8 8.3 9.1 10.8 0001 0601 1201 1801 2400 DAILY VALUE 9.3 9.8 10.3 9.3 9.3 9.3 9.8 10.0 10.3 10.3 10.3 10.3 9.3 9.8 10.3 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE 0600 1200 1800 1801 2400 DAILY VALUE 0001 0601 1201 - 0600 1200 1800 0001 0601 1201 1801 2400 DAILY VALUE MONTHLY VALUE 8.3 ---12.8 4-C-91 4-C-92 - - Table 4·-G-25.Cont. -AUGUST 1982 - --------------------~---------------------------~------------------------------- TIME PERIOD 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE DAYS 1 - 8 MIN MEAN MAX 10.0 10.5 11.0 9.5 9.8 10.0 10.5 10.8 11.0 11.0 11.2 11.5 9.5 10.6 11.5 DAYS 9 -16 MIN MEAN MAX 9.0 9.5 10.0 8.5 8.7 9.0 9.5 10.2 10.5 10.5 10.5 10.5 8.5 9.7 10.5 DAYS 17 -24 MIN MEAN MAX 9.5 9.8 10.0 9.5 9.5 9.5 10.0 10.2 10.5 9.5 10.0 10.5 9.5 9.9 10.5 DAYS 25 -31 MIN MEAN MAX 10.5 10.7 11.0 10.0 10.2 10.5 11.0 11.5 12.0 10.5 11.0 11.5 10.0 10.8 12.0 0001 -0600 10.5 11.3 12.0 0601 -1200 10.5 10.8 11.5 1201 -1800 12.0 12.7 13.0 1801 -2400 13.0 13.2 13.5 DAILY VALUE 10.5 12.0 13.5 0001 -0600 '10.0 10.811.5 0601 -1200 10.0 10.5 11.0 1201 -1800 12.0 12.5 13.0 1801 -2400 12.5 12.7 13.0 DAILY VALUE 10.0 11.6 13.0 0001 -0600 11.5 12.0 12.5 0601 -1200 11.5 11.5 11.5 1201 -1800 12.0 12.0 12.0 1801 -2400 11.0 11.5 12.0 DAILY VALUE 11.0 11.7 12.5 0001 -0600 10.5 11.0 11.5 0601 -1200 10.0 1Q.3 11.0 1201 -1800 11.5 12.2 13.0 1801 -2400 12.5 12.8 13.0 DAILY VALUE 10.0 11.6 13.0 0001 -0600 11.0'11.5 12.0 0601 -1200 10.5 11.0 11.5 1201 -1800 12.0 12.813.5 1801 -2400 12.5 12.7 13.0 DAILY VALUE 10.5 12.0 13.5 8.5 8.5 8.5 8.5 8.5 8.5 9.0 9.0 9.0 8.5 8.7 9.0 8.5 8.7 9.0 8.0 8.0 8.0 8.0 8.0 8.0 9.0 9.0 9.0 8.5 8.8 9.0 8.0 8.5 9.0 8.5 9.0 9.5 8.0 8.3 9.0 9.5 9.7 10.0 10.0 10.0 10.0 8.0 9.2 10.0 9.0 9.2 9.5 8.5 8.5 8.5 8.5 8.5 8.5 9.0 9.0 9.0 8.5 8.8 9.5 8.5 9.0 9.5 8.5 8.7 9.0 9.5 10.0 10.5 10.0 10.2 10.5 8.5 9.5 10.5 9.0 9.3 9.5 9.0 9.3 10.0 10.5 11.0 11.5 10.5 10.8 11.0 9.0 10.1 11.5 12.0 12.2 12.5 11.5 11.7 12.0 12.0 12.3 12.5 12.0 12.3 12.5 11.512.112.5 11.0 11.2 11.5 11.0 11.2 11.5 12.0 12.5 13.0 12.5 12.8 13.0 11.0 11.9 13.0 11.0 11.5 12.0 10.5 10.7 11.0 12.0 12.3 12.5 12.5 12.5 12.5 10.5 11.7 12.5 8.5 9.0 9.5 8.0 8.1 9.5 10.0 10.8 11.5 11.0 11.3 11.5 8.0 10.0 11.5 10.0 10.2 10.5 9.5 10.0 10.5 11.5 12.0 12.5 11.5 11.1 12.0 9.5 11.0 12.5 10.0 10.5 11.0 10.0 10.0 10.0 11.0 11.7 12.0 12.0 12.0 12.0 10.0 11.0 12'.0 10.5 11.3 12.0 10.5 10.7 11.0 11.0 11.0 11.0 10.5 10.8 11.0 10.5 11.0 12.0 11.5 12.3 13.0 11.5 11.7 12.0 12.5 12.5 12.5 12.5 12.5 12.5 11.5 12.2 13.0 10.5 11.0 11.5 10.0 10.7 11.5 12.5 13.3 14.0 13.5 13.8 14.0 10.0 12.2 14.0 9.5 9.8 10.0 9.5 9.7 10.0 10.0 10.3 10.5 10.0 10.2 10.5 9.5 10.0 10.5 9.5 9.1 10.0 9.0 9.0 9.0 10.0 10.5 11.0 10.5 10.8 11.0 9.0 10.0 11.0 8.5 9.3 10.0 8.5 9.0 9.5 11.0 11.812.5 12.0 12.5 13.0 8.5 10.7 13.0 10.0 10.3 10.5 10.0 10.3 11.0 12.0 12.3 12.5 11.5 11.8 12.0 10.0 11.2 12.5 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 10.0 10.2 10.5 9.5 9.7 10.0 10.0 10.3 10.5 10.0 10.3 10.5 9.5 10.1 10.5 9.0 9.5 10.0 8.5 8.7 9.0 10.0 10.7 11.0 10.5 10.8 11.0 8.5 9.9 11.0 11.0 11.5 12.0 --------------- 11.0 11.0 11.0 MONTHLY VALUE 11.5 11.8 12.0 --------------- 11.0 11.3 11.5 8.0 ----14.0 11.0 11.4 12.0 4-C-93 Table 4-C-25 Cont.~ ~. -SEPTEMBER 1982 -~-------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX --------------------------------------------------------------------------------~ 0001 -0600 8.0 8.2 8.5 7.0 7.2 7.5 6.0 6.5 7.0 4.0 4.0 4.0 0601 -1200 7.5 7.8 8.0 7.0 7.0 7.0 5.5 5.8 6.0 3.5 3.7 4.0 1201 -1800 9.0 9.2 9.5 7.0 7.5 8.0 6.0 6.5 7.0 4.5 4.8 5.0 ..... 1801 -2400 8.0 8.8 9.5 7.0 7.3 7.5 6.5 6.5 6.5 5.0 5.0 5.0 DAlLY VALUE 7.5 8.5 9.5 7.0 7.2 8.0 5.5 6.3 7.0 3.5 4.4 5.0 0001 -0600 7.5 7.7 8.0 6.0 6.5 7.0 6.0 6.2 6.5 4.5 4.7 5.0 -0601 -1200 7.0 7.3 8.0 6.0 6.0 6.0 5.5 5.7 6.0 4.0 4.2 4.5 1201 -1800 8.5 8.5 8.5 6.5 7.0 7.5 6.0 6.0 6.0 4.5 4.8 5.0 1801 -2400 8.5 8.5 8.5 7.0 7.2 7.5 6.0 6.0 6.0 4.5 4.8 5.0 DAILY VALUE 7.0 8.0 8.5 6.0 6.7-7.5 5.5 6.0 6.5 4.0 4.6 5.0 0001 -0600 7.5 7.8 8.0 5.5 6.2 7.0 5.5 5.8 6.0 4.0 4.2 4.5 0601 -1200 7.5 7.5 7.5 5.5 5.7 6.0 5.5 5.5 5.5 4.0 4.0 4.0 1201 -1800 8.0 8.0 8.0 6.0 6.2 6.5 6.0 6.0 6.0 4.0 --4.0 1801 -2400 7.5 7.7 8.0 5.5 5.8 6.0 6.0 6.0 6.0 ~....--- DAlLY VALUE 7.5 7.7 8.0 5.5 6.0 7.0 5.5 5.8 6.0 4.0 --4.5 0001 -0600 6.5 6.8 7.0 4.0 4.5 5.0 5.0 5.5 6.0 ------ --- 0601 -1200 6.5 6.7 7.0 4.0 4.2 4.5 5.0 5.0 5.0 --...--- 1201 -1800 7.0 7.2 7.5 5.0 5.2 5.5 5.5 5.5 5.5 --------- 1801 -2400 7.0 7.2 7.5 5.5 5.5 5.5 5.5 5.5 5.5 ---------~I DAILY VALUE 6.5 7.0 7.5 4.0 4.8 5.5 5.0 5.4 6.0 ------- 0001 -0600 6.0 6.3 6.5 5.5 5.5 5.5 5.0 5.3 5.5 --------0601 -1200 6.0 6.2 6.5 5.0 5.0 5.0 5.0 5.0 5.0 ~----- , 1201 -1800 7.5 7.8 8.0 5.5 5.7 6.0 5.5 5.8 6.0 ------- 1801 -2400 7.5 7.8 8.0 5.5 5.7 6.0 6.0 6.0 6.0 ------ DAILY VALUE 6.0 7.0 8.0 5.0 5.5 6.0 5.0 5.5 6.0 --------- 0001 -0600 7.0 7.3 7.5 5.5 5.5 5.5 5.0 5.2 5.5 --- 0601 -1200 6.5 6.7 7.0 5.5 5.7 6.0 4.5 4.7 5.0 ---------- 1201 -1800 7.5 7.8 8.0 6.0 6.3 6.5 5.5 5.5 5.5 -..------1801 -2400 8.0 8.0 8.0 6.5 6.5 6.5 5.0 5.2 5.5 ------- DAILY VALUE 6.5 7.5 8.0 5.5 6.0 6.5 4.5 5.1 5.5 ----------0001 -0600 7.5 7.7 8.0 6.0 6.0 6.0 4.0 4.5 5.0 --.---- 0601 -1200 7.5 7.7 8.0 6.0 6.2 6.5 4.0 4.2 4.5 -..------ 1201 -1800 8.0 8.0 8.0 7.5 7.8 8.0 5.0 5.3 5.5 ------- 1801 -2400 8.0 8.0 8.0 8.0 8.0 8.0 4.5 5.0 5.5 ----- DAILY VALUE 7.5 7.8 8.0 6.0 7.0 8.0 4.0 4.7 5.5 ------ 0001 -0600 7.5 7.5 7.5 7.0 7.2 7.5 3.0 3.3 4.0 -.------ 0601 -1200 7.0 7.2 7.5 6.0 6.2 6.5 2.0 2.•5 3.0 MONTHLY VALUE 1201 -1800 7.5 7.5 7.5 6.5 6.8 7.0 3.5 3.7 4.0 ...-..-.------- 1801 -2400 7.5 7.5 7.5 7.0 7.0 7.0 4.0 4.0 4.0 2.0 6.2 9.5 DAILY VALUE 7.0 7.4 7.5 6.0 6.8 7.5 2.0 3.4 4.0 ~ ----------------------------------------------------------------------------~~ 4-C-·94 - ,.... Table 4-C-26.Weekly minimum!mean nnd maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and 1 i sted by USGS water year week!Su Station!RM 25.8,GC S17N07W22DCD. WATER STARTING YEAR CALENDAR WEEK DATE WEEKLY VALUE (c) ------------------- MIN MEAN MAX IF OF 2-HQURLY READINGS IF OF DAYS IN RECORD -------------------------------------------------------------- .... - 33 34 35 36 37 820513 820520 820527 820603 820610 1.9 2.9 4.9 6.9 7.9 2.7 4.9 7.5 7.5 7.9 3.4 6.9 9.9 8.4 7.9 4-C-95 42 84 84 84 8 4 7 7 7 1 Table 4-C-27.Weekly mln1mum.mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week.Yentna Fishwheel.RM 28.0.TRM 4.0. GC S18N07W34DBC. WATER STARTING YEAR CALENDAR WEEK DATE WEEKLY VALUE (C) MIN MEAN MAX 4/OF 2-HOURLY READINGS 41 OF DAYS IN RECORD ------------------.--~-------------------------------------~- 36 37 38 39 40 41 42 ,43 44 45 46 47 48 49 50 51 52 1 2 820603 820610 820617 820624 820701 820708 820715 820722 820729 820805 820812 820819 820826 820902 820909 820916 820923 821001 821008 7.5 6.5 7.0 8.5 7.0 8.0 7.0 7.0 7.•5 7.0 7.5 8.0 7.0 7.0 5.5 5.5 3.5 .5 0.0 7.7 7.7 8.7 10.6 8.6 9.2 9.0 8.0 8.9 9.0 8.8 8.5 8.0 7.4 6.5 6.1 4.6 1.6 .7 8.0 8.5 10.5 13 .0 10.0 11.0 12.0 10.5 10.0 11.0 10.5 9.0 9.0 8.0 7.5 7.0 6.0 4.0 1.0 4-C-96 16 84 84 84 84 84 84 84 84 84 84 84 84 84 83 82 54 40 43 2 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 5 4 4 - - -- - Table 4-C-28.Weekly mlnlmum t mean and maximum (;umme\~sur-fiier water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Susitna River-Upstream of Yentna River, RM 29.5,GC S17N06W07CAD. ----------------------~--------------------------------------WATER STARTING WEEKLY VALUE (C)II OF II OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 3.6 820603 7.5 7.9 8.5 16 2 37 820610 7.5 7.9 8.5 53 5 38 820617 8.0 9.5 11.5 65 6 39 820624 10.5 11.8 13.5 84 7 40 820701 9.5 11.0 13.0 84 7 41 820708 10.5 11.4 12.5 84 7 42 820715 9.5 11.1 13 .5 84 7 43 820722 9.0 10.0 11.5 84 7 44 820729 10.0 10.9 12.0 84 7 45 820805 8.5 10.8 13.0 83 7 46 820812 9.5 10.6 12.0 84 7 """'"""47 820819 9.0 10.4 11.0 84 7 48 820826 8.5 9.6 11.0 84 7 49 820902 7.5 8.7 9.5 84 7-50 820909 6.5 7.5 8.5 83 7 I 51 820916 6 .0 6.9 8.0 84 7 52 820923 4.0 5.0 6.0 96 8 1 821001 1.0 3.4 5.0 77 7 2 821008 0.0 1.1 1.5 84 7 3 821015 0.0 .0 .5 32 3 -------------------------------------------------------------- 1"." /'~- 4-C-97 Table 4-C-29.Weekly mlnlmUm,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Parks Highway Bridge-West,RM 83.9,GC S24N05W15BAB. - ,~ WATER YEAR WEEK STARTING CALENDAR .DATE WEEKLY VALUE (c) MIN MEAN MAX 1/OF 2-HOURLY READINGS 1/OF DAYS IN RECORD 36 820603 8.1 8.2 8.6 17 2 37 820610 6.6 7.9 9.6 84 7 38 820617 7.1 9.0 10.6 84 7 .-39 820624 8.6 ·10.4 12.1 84 7 40 820701 7.6 9.4 11.6 83 7 41 820708 9.1 10.3 11.1 22 2 - 4-C-98 Table 4-C-30.Weekly mlnlmUm,mean and max.imum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Parks Highway Bridge-East.RM 83.9.GC S24N05W15BAD. - !"'" - -------------------------------------------------------------- WATER STARTING .WEEKLY VALUE (c)#:OF 4J:OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 47 820819 9.5 9.9 10.5 39 4 48 820826 8.0 8.7 10.0 84 .7 49 820902 .7.0 7.8 8.5 84 7 50 820909 5.5 6.7 8.0 84 7 51 820916 5.6 6.2 7.0 84 7 52 820923 4.1 4.6 5.6-96 8 1 820101 1.2 2.9 4.6 84 7 2 821008 .7 1.1 1.7 84 7 3 821015 .2 .2 .7 84 7 4 821022 .2 .2 .2 52 5 -------------------------------------------------------------- 4-C-99 Table 4-C-31.Weekly mlnlmum.mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermoqraph readings and listed by USGS water year week.L~X 1.RM 97.0.GC S26N05W23DCB. - -------------------~-------~--~------~---------~---~---------- WATER STARTING YEAR CALENDAR WEEK DATE WEEKLY VALUE (c) MIN MEAN MAX 4F OF 2-HOURLY READINGS 4F OF nAYS IN RECORD - ----------------------'---'---'-'--------------'------------------- ----------------------~--------------------------------------- 4-C-IOO - - - Table 4-C-32.Weekly mlnlmUm,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph read;ngs and 1;sted by USGS water y'ear week,Talkeetna Rivpr,RM 97.?TR~1 1.5, GC S26N05W24BDA. WATER STARTING YEAR CALENDAR WEEK DATE WEEKLY VALUE (C) MIN MEAN MAX :1ft OF 2-HOURLY READINGS :1ft OF DAYS IN RECORD 36 37 38 39 44 45 46 47 48 49 50 51 52 1 2 3 4 820603 820610 820617 820624 820729 820805 820812 820819 820826 820902 820909 820916 820923 821001 821008 821015 821022 6.4 5.9 5.9 9.4 8.5 8.5 8.5 8.5 8.0 7.1 5.1 5.1 3.6 1.1 .6 .1 .1 6.7 6.9 6.8 9.4 8.0 10.4 9.6 10.4 9.5 10.5 9.5 11.0 9.7 11.5 9.8 11.0 8.8 10.5 7.7 9.0 6.5 7.6 5.9 7.1 4.3 5.1 2.8 4.6 1.6 2.1 .2 1.1 .1 .1 4-C-10l 18 84 84 7 55 84 83 84 84 83 84 84 96 84 84 84 7 2 7 7 1 5 7 7 7 7 7 7 7 8 7 7 7 1 ~ Table 4-C-33.Weekly mlnlmum,mean and maximum summersu rface c'- water temperature (C)obtained from 2-hour Ryan ~thermograph readings and 1is ted by USGS water year week,Chul itna River~RM 98.6,TRM 0.6, GC S26N05W14CBC....., -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)#OF ..#OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX.READINGS RECORD -------------------------~.----------------------------------- 36 820603 5.0 6.1 7.0 18 2 37 820610 5.0 5.8 7.0 84 7 38 820617 5.0 6.1 6.5 84 7 39 820624 6.5 6.6 7.0 5 1 47 820819 6.5 7.0 8.0 39 4 48 820826 5.5 6.1 7.0 84 7 ~ 49 820902 5.5 6.0 7.0 83 7 50 820909 4.0 5.3 8.5 82 7 51 820916 3.5 4.5 6.5 84 7 52 820923 2.5 3.1 4.0 28 3 2 821008 0.0 .6 1.5 66 6 3 821015 0.0 0.0 0.0 84 7 4 821022 0.0 0.0 0.0 7 1 ........- -------------------------------------------------------------- 4-C-I02 - - - Table 4-C-34.Weekly mln1mUm,mean and maximum summer surface water temperature (C)obtained frnf!1 2-hour Ryan thermograph readings and 1;sted by USGS water ye"Jr week,Talkeetna Fishwheel,Rt·1 103.0,GC S27N05W26DDD. - -, - - -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (C)4/OF 4/OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 39 820624 11.1 12.6 14.1 78 7 40 820701 8.6 11.1 14.9 31 4 41 820708 10.4 12.0 13.9 84 7 42 820715 9.4 11.4 14.4 84 7 43 820722 8.9 10.5 12.4 84 7 44 820729 9.9 11.1 13 .4 81 7 45 820805 9.4 11.1 13.4 84 7 46 820812 9.4 11.2 12.9 84 7 47 820819 9.9 11.6 12.9 84 7 48 820826 8.4 10.0 12.4 84 7 49 820902 7.9 8.6 9.4 84 7 50 820909 5.9 7.3 8.9 84 7 51 820916 6.4 7.2 7.9 11 2 52 820923 4.4 5.0 6.4 96 8 1 821001 1.4 3.2 4.9 84 7 2 821008 .2 .7 1.4 79 7 3 821015 .2 .2 .2 84 7 4 821022 .2 .2 .2 55 5 -------------------------------------------------------------- 4-C-I03 Table 4-C-35.Weekly mlnlmum,mean and maximum summer surface water temperatur.e (C)obtained from 2-hour Ryan thermograph readlngs and listed by USGS water year week,LRX 18,RM 113.0,GC S28N04W12DAB.' 4-C-104 - - - -, Table 4-C-36.Weekly minimum,mean and maximum Sl)mm~r SIJrface water temperature (C)obtained ·~'rorn :2-hour Ryan thermograph readings and 1 isted b.y USGS water year week,Curry Fishwheel,R~1120.7,GC S29N04WIOCBB. --------------------------------------------------------------...... WATER STARTING WEEKLY VALUE (c)it OF it OF YEAR CALENDAR --------------~----2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD ------------------------------------------------------------~- 40 820701 14.1 14.1 14.1 2 1 41 820708 10.6 12.1 14.1 84 7 42 820715 10.1 11.5 13.6 84 7 43 820722 9.1 10.5 12.6 84 7 44 820729 9.6 11.0 12.4 83 7 45 820805 9.4 11.2 12.9 84 7 46 820812 9.4 11.0 12.4 84 7 47 820819 9.9 11.3 12.4 84 7 48 820826 8.4 9.7 11.9 84 7 49 820902 7.6 8.2 9.1 84 7 50 820909 6.1 6.9 8.1 84 7 !"""-51 820916 6.0 6.8 7.6 84 7 52 820923 4.5 5.0 6.0 92 8 ----------------~----~---------------------------------------- -4-C-105 Table 4-C-37.Weekly mlnlmum,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,510ugh 8A-Area of R&M Stage Recorder,RI\~ 126.0,GC S30N03W30BCA. 4-C-106 ~I Table 4-C-38.Weekly mlnlmum,mean and maximum summer surface \'Jater temperature (C)obtai ned ft'om 2-hour Rvan thermograph readings andlisled by USGS water year week,LRX 29,RM 126.1,GC S30N03W19DCA. -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)4f OF 4f OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 41 820708 11.2 12.1 15.7 64 6 42 820715 10.2 12.0 15.2 84 7 43 820722 9.7 10.8 12.7 64 6 44 820729 10.2 11.4 14.6 75 7 45 820805 10.1 11.6 13 .6 84 7 46 820812 9.6 11.4 13.1 84 7 47 820819 10.1 11.6 13.1 84 7 48 820826 8.6 10.0 12.1 84 7 49 820902 8.0 8.7 10.0 84 7 50 820909 6.5 7.6 8.5 84 7 51 820916 5.3 6.8 8.0 84 7 ~,,(1l1Aw......,52 820923 3.8 4.3 5.3 96 8 1 821001 3.8 3.8 3.8 5 1 --------------~-----------------------------------------------~ "'"' 4.,.C-I07 Table 4-C-39.Weekly mlnlmum,mean and maximum summer surface wate~temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,510ugh 9-Area of R&M Stage Recorder.RM 129.2,GC S30N03WI6ACB. - -------------------------~-----~------------------------------WATER STARTING WEEKLY VALUE (c)1/OF 1/OF ~j YEAR CALENDAR ----------~--------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD --------------------------~-----------~---------------~--------43 820722 12.0 12.3 12.5 6 1 44 820729 7.5 10.5 13.5 84 7 45 820805 6.5 9.2 13.5 84 7 46 820812 6.5 8.8 12.5 84 7 47 820819 6.0 8.8 12.5 84 7 48 820826 6.0 8.1 11.5 84 7 49 820902 6.5 7.6 9.5 84 7 50 820909 5.0 6.8 8.0 60 5 51 820916 4.9 6.2 6.9 30 3 52 820923 2.9 4.8 5.9 96 8 1 821001 1.2 3.1 5.2 84 7 2 821008 1.2 2.3 3.7 84 7 3 821015 L2 L8 2.7 84 7 ~-4 821022 .7 LO L7 84 7 5 821029 .7 .8 1.2 18 2 ~-------------------------------------------------------------- ~J ~I 4-C-108 eo-, i Table 4-C-40.Weekly ml nlmum,mean and maximum summer surface water temperature (C)obtained from 2-houy'Ryan thermograph read;ngs and 1 i sted by USGS water yea r week,LRX 35,RM 130.8.GC S30N03W03DCA. WATER STARTING YEAR CALENDAR WEEK DATE WEEKLY VALUE (C) MIN MEAN MAX //OF .2-HOURLY READINGS i/OF DAYS IN RECORD 49 50 51 820902 820909 820916 7.1 5.6 6.1 7.6 6.3 6.7 8.6 7.6 7.6 4-C-109 77 84 36 7 7 3 Table 4~C-41.Weekly mln,mum~mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and llsted by USGS water year week~Indian River,RM 138.6,GC S31N02W09CDA.- -------------------------------------------------------------- WATER STARTING WEEKLY V.ALUE (c)/I:OF #OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 36 820603 2.5 4.1 5.5 19 2 37 820610 2'.5 4.2 LO 84 7 38 820617 3.5 5.3 8.5 81 7 39 820624 4.5 6.5 9.0 84 7 I 40 820701 5.0 7.4 11.5 84 7 41 820708 6.5 8.0 10.0 84 7 42 820715 6.5 8.6 12.5 84 7 43 820722 6.5 7.3 9.0 84 7 44 820729 6.0 7.7 10.0 78 7 - 4-C-110 -, ,.,~ Table 4-C-42.Weekly mlmmum,mean and maximum summer surface water temperature (C)obta'ined from ?-hour Rvan thr>rmograph readings and 1-j sted by USGS water y'ear week,LRX 53,RM 140.1.GC S31NI1WIOAAC. -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)1;OF 1;OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 44 820729 12.2 12.2 12.2 6 1 ,lPI/iII 45 820805 10.2 11.3 12.7 84 7 46 820812 9.7 11.2 12.7 84 7 47 820819 10.2 10.7 11.2 83 7 48 820826 8.2 9.5 10.7 83 7 49 820902 7.9 8.3 8.9 84 7 50 820909 5.9 7.0 7.9 65 6 '"""I i i""'" I ! 4-C-ll1 Table 4-C-43.Weekly ml mmum,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 21-Area of R&M Stage Recorder,RM 142.0,GC S32N02W36CCC. - -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (C)1J OF 1}OF ~, YEAR CALENDAR ----~--------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 43 820722 6.0 7.2 8.5 7 1 44 820729 4.5 6.2 9.0 84 7 45 820805 4.5 4.•5 4.5 84 7 .,... 46 820812 4;.5 5.0 7.5 84 7 47 820819 4·5 5.8 8.5 83 7 48 820826 4.0 5.4 8.0 84 7 ~ 49 820902 4.5 5.3 7.0 84 7 50 820909 4.0 5.1 7.5 84 7 51 820916 4.0 5.7 8.0 84 7 52 820923 3.5 4.3 5.0 96 8 ~ 1 821001 3.5 3.9 5.0 81 7 2 821008 3.0 3.6 4.5 84 7 3 821015 2.0 3.0 4.0 84 7 ~.- 4 821022 1.5 2.2 2.5 67 6 --------------------------------------------------------------M'Jt - 4-C-1l2 Ti1hle 4 -C-41',.hef~k'ly fIl11'l11l1Um,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Portage Creek,RM 148.8,TRM 0.1 GC S32N01W25CAB.' ------------------------------------------------~------------- WATER STARTING WEEKLY VALUE (c)41 OF if OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD ----------------------------------------------------,---------- 36 820603 2.2 3.4 4.7 19 2 37 820610 1.7 3.4 4.7 48 4 39 820624 4.0 5.9 8.5 84 7 40 820701 4.5 5.4 6.5 15 2 41 820708 6.5 7.5 9.5 76 7 42 820715 6.0 8.2 11.5 84 7 43 820722 6.0 6.9 9.5 82 7 44 820729 7.0 7.9 10.5 34 4 45 820805 6.5 8.0 10.5 84 7 46 820812 5.5 8.4 10.5 84 7 47 820819 6.5 8.7 10.5 84 7 48 820826 6.0 7.6 10.0 65 6 -:'~~ -------------------------------------------------------------- 4-C-113 Table 4-C-45.Weekly mlnlmum,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Tsusena Creek,RM 181.3,GC S32N04E36ADB. -------------------------------~------------------------------WATER STARTING WEEKLY'VALUE (c)41 OF fF OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------~------------------------------------------------ 38 820617 4.0 6.0 10.0 54 5 39 820624 4.0 6.7 10.5 84 7 40 820701 4.5 7.6 12.5 84 7 41 820708 6.5 8.4 10.5 84 7 42 820715 6.5 9.0 13 .5 84 7 43 820722 6.5 7.9 11.0 83 7 ~ 44 820729 6.0 8.0 11.0 84 7 45 820805 6.5 8.3 11.0 84 7 46 820812 5.5 8.7 12.0 84 7 -47 820819 6.0 9.0 11.0 84 7 48 820826 6.0 7.7 10.0 84 7 49 820902 5.5 6.7 8.5 84 7 50 820909 4.5 5.9 7.5 84 7 51 820916 4.5 5.3 6.5 84 7 52 820923 2.0 4.0 5.5 96 8 1 821001 0.0 2.0 4.0 84 7 2 821008 0.0 .6 1.5 84 7 3 821015 0.0 0.0 0.0 18 2 -------------------------------------------------------------- - 4-0-114 Tablp 4-C-46.Heekly mlmmUffi,mean and maXirrllJITl ",umf'l(''('::u ~;':f' water temperature (C)obtained from 2-hour Rv"l1 thermograph readings and listed by USGS water year week,Watana Creek,R~1194.1,GCS32N06E25CCA. --------------------------------------------------------------~ WATER STARTING WEEKLY VALUE (c)#OF #OF YEAR CALENDAR -------------------2-HOURLY DAYS IN .WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 38 820617 5.0 7.3 12.0 39 4 39 820624 6.0 9.4 13 .0 84 7 40 820701 6.0 9.5 15.5 84 7 41 820708 8.0 10.1 13 .0 84 7-42 820715 6.5 9.7 14.0 79 7 43 820722 7.0 9.0 12.0 84 7 44 820729 5.6 8.1 11.1 83 7 45 820805 6.1 7.9 10.6 84 7-46 820812 4.6 8.4 11.6 44 4 49 820902 6.5 6.7 7.0 3 1 50 820909 4.0 5.6 8.0 84 7 ~.~51 820916 4.5 5.6 6.5 40 4 52 820923 2.0 3.3 5.5 43 4 1 821001 .5 1.8 3.0 83 7 2 821008 .5 .7 1.5 84 7.- 3 821015 .5 .5 .5 17 2 -------------------------------------------------------------- ".., 4-C-115 Table 4-C-47.Weekly mlmmum,mean and maximum summer surface water temperature (C)obtained from 2-hour Ryan thermograph readi ngs and 1i sted by USGS water year week,Kosina Creek,RM 206.8,GC S31N08E15BAB. - WATER STARTING YEAR CALENDAR WEEK DATE WEEKLY VALUE (C) MIN MEAN MAX fF OF 2-HOURLY READINGS #OF DAYS IN RECORD 39 40 41 42 43 44 45 46 51 52 1 2 3 820624 820701 820708 820715 820722 820729 820805 820812 820916 820923 821001 821008 821015 6.5 7.0 9.5 9.0 10.0 9.0 9.0 7.5 4.1 1.1 .1 .1 .1 10.0 10.9 11.3 11.6 12.1 11.6 11.1 10.5 5.0 2.8 1.4 .1 .1 14.5 16.0 14.5 16.0 15.0 14.5 14.0 13 .5 6.6 4.6 2.6 .1 .1 4-C-1l6 43 84 84 84 84 84 84 72 41 95 84 84 18 4 7 7 7 7 7 7 6 4 8 7 7 2 - - - Table 4,..C-48.Weekly minimum,mean and.maximum summer surface Wi'lter temperature (C)obtained from 2-hour Ryan thermograph readings and 1 isted by USGS water year week,Goose Creek,RM 231.3,GC S30NI1E32DBC. ---------------------------------------------------------------WATER STARTING.WEEKLY VALUE (c)It OF It OF YEAR CALENDAR -----------~~------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS·RECORD -------------------------------------------------------------- 39 820624 8.5 11.3 15.0 42 4 40 820701 7.0 11.1 16.5 84 7 41 820708 9.5 11.9 15.5 84 7 42 820715 8.5 11.3 16.0 84 7 43 820722 9.0 12.2 16.5 84 7 ~44 820729 8.5 11.7 15.0 84 7 45 ·820805 8.5 11.2 15.0 84 7 46 820812 7.0 10.9 15.5 84 7 47 820819 9.0 11.5 14.0 84 7 48 820826 7.0 9.0 12.0 84 7 49 820902 5.5 7.4 9.5 84 7 50 820909 3.0 5.9 9.0 84 7 ID1IIl.J~51 820916 4.5 5.9 7.5 84 7 52 820923 1.0 3.3 6.0 96 8 1 821001 .5 1.5 3.0 84 7 2 821008 0.0 .5 1.0 83 7 3 821015 .5 .5 .5 18 2 ....-------------------------------------------------------------- -. ..... 4-C-117 Table 4-C-49.Weekly mlnlmUm,mean and maximum summer surface water'temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water ye~r week,OshetnaRiver,RM 233.4,GC S30NllE34CCD. ------------~---~~--~-----------------------------------------WATER STARTING WEEKLY VALUE (c)11 OF 11 OF YEAR CALENDAR -------~-------~---2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD ---------------------------------~----------------------------- 39 820624 8.3 10.3 12.8 42 4 40 820701 8.3'9.1 9.8 18'2 41 82070.8 9.8 11.4 13.8 81 7 42 820715 9.3 11 •.6 14.8 84 7 43 820122 11.3 12.8 14.5 12 2 44 820729 9.5 11.4 13.5 84 7 45 820805 8.5 10.7 13.5 84 7 46 820812 8.0 10 •.8 14.0 84 7 47 820819 9.5 11.4 13.0 84 7 48 820826 7.5 9.0 11.5 84 7 49 820902 6.0 7.5 8.5 84 7 50 820909 4.0 6.2 8.0 83 7 51 820916 4.5 5.9 7.5 84 7 --52 820923 2.0 4.3 5.5 55 5 ---------------------------------~--------~~---~-------------- ~I 4-C-118. Table 4--C-50.Datapod intragravel and surface water temperature (C)continuous record,at Slough SA-Mouth,RM 125.4,Geocode S30N03W30BCD. note,that time periods are 6 hours and 3 minutes and 42 seconds in duration;accordingly,daily minimum,maximum and mean values can not be directly calculated from this data. ----------------------------------------------------------------------------- DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX ----------------------------------------------------------------------------- - ,..,. 820821 -820821 820821 -820821 820821 -820821 820821 -820822 820822 -820822 820822 -820822 820822-820822 0023 -0626 0627 -1229 1230 -1833 1834 -0037 0038 -0641 0642 -1244 1245 -1848 6.5 6.4 6.5 6.8 6.5 6.5 6.6 6.6 6.5 6.6 6.8 6.7 6.6 6.7 6.7 6.6 6.7 6.8 6.8 6.6 6.8 8.0 7.8 12.1 9.6 8.0 8.2 12.5 8.8 9.3 13.9 11 .S 8.9 9.8 14.1 9.8 12.0 14.7 13.9 9.7 12.5 14.8 820822 -820823 1849 -0052 6.8 6.8 6.8 10.7 11.7 13 .8 820823 -820823 820823 -820823 820823 -820823 0053 -0655 0656 -1259 1300 -1903 6.6 6.6 6.7 6.7 6.6 6.7 6.8 6.7 6.8 10.0 9.8 11.6 10.3 10.4 12.3 10.7 11.5 12.7 -820823 -820824 1904 -0106 6.7 6.7 6.8 10~0 10.8 12.2 820824 -820824 820824 -820824 820824 -820824 820824 -820825 820825 -820825 820825 -820825 820825 -820825 820825 -820826 820826 -820826 820826 -820826 820826 -820826 820826 -820827 820827 -820827 820827 -820827 820827 -820827 0107 -0710 0711 -1314 1315 -1918 1919 -0121 0122 -0725 0726 -1329 1330 -1932 1933 -0136 0137 -0740 0741 -1343 1344 -1947 1948 -0151 0152 -0755 0756 -1358 1359 -2002 6.6 6.5 6.6 6.7 6.8 6.7 6.7 6.8 6.8 6.7 6.7 6.9 6.7 6.6 6.6 4-G-1l9 6.6 6.6 6.7 6.8 6.8 6.8 6.8 6.8 6.8 6.8 6.9 7.0 6.8 6.7 6.8 6.7 6.7 6.8 6.8 6.8 6.8 6.8 6.9 6.9 6.8 7.0 7.1 6.9 6.8 6.8 9.1 9.2 11.9 10.0 9.5 9.4 11.1 9.7 9.3 9.3 12.7 9.7 7.8 7.8 13 .0 9.5 10.2 12.6 11.1 9.8 9.9 12 .5 11.0 9.4 10.4 14.1 U.5 8.7 10.2 14.1 10.0 11 .8 12.9 12.5 10.1 11.0 13 .2 12.6 9.7 12.6 14.8 14.0 9.7 13 .4 14.6 ~-Table 4-C-50.Cont. f""" ----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------- 820903 -820904 2147 -0349 6.3 6.3 6.4 6.8 7.3 7.7 -820904 -820904 0350 -0953 6.2 6.3 6.3 6.4 6.6 6.8 820904 -820904 0954 -1557 6.2 6.2 6.2 6.5 7.5 8.5 820904 -820904 1558 -2200 6.2 6.2 6.3 7.8 8.5 9.0 820904 -820905 2201 -0404 6.2 6.3 6.3 6.7 7.3 7.8 820905 -820905 0405 -1008 6.2 6.2 6.3 6.3 6.5 6.8 820905 -820905 1009 -1611 6.1 6.2 6.2 6.7 7.7 8.3 820905 -820905 1612 -2215 6.1 6.2 6.2 7.8 8.2 8.4 820905 -820906 2216 -0419 6.2 6.2 6.3 7.0 7.4 7.8 820906 -820906 0420 -1023 6.2 6.2 6.2 6.5 6.8 7.1 820906 -820906 1024 -1626 6.2 6.2 6.3 6.9 7.6 7.8 -.~820906 -820906 1627 -2230 6.2 6.3 6.3 7.4 7.7 7.9 820906 -820907 2231 -0434 6.2 6.3 6.3 7.0 7.3 7.5 ~, 820907 820907 0435 -1037 6.2 6.2 6.3 6.8 7.0 7.5- 820907 -820907 1038 -1641 6.2 6.2 6.3 7.5 8.9 9.8 820907 -820907 1642 -2245 6.3 6.3 6.3 8.5 8.9 9.6 820907 -820908 2246 -0448 6.3 6.3 6.4 7.9 8.2 8.6 ..-820908 -820908 0449 -1052 6.2 6.3 6.3 7.5 7.7 8.1 820908 -820908 1053 -1656 6.3 6.3 6.3 8.2 8.7 8.9 820908 -820908 1657 -2300 6.3 6.3 6.4 8.0 8.3 8.7 820908 -820909 2301 -0503 6.3 6.3 6.3 7.6 7.8 7.9 820909 -820909 0504 -1107 6.3 6.3 6.3 7.3 7.4 7.6~820909 -820909 1108 -1711 6.3 6.3 6.3 7.6 8.4 9.1 820909 -820909 1712 -2314 6.3 6.3 6.4 7.8 8.5 9.1 820909-820910 2315 -0518 6.3 6.3 6.4 7.2 7.4 7.7 820910 -820910 0519 -1122 6.2 6.3 6.4 6.9 7.1 7.6-820910 -820910 1123 -1725 6.2 6.3 6.3 7.7 8.5 8.9 820910 -820910 1726 -2329 6.2 6.3 6.3 7.5 8.2 8.9 t~ ~--------~-~------------~----------------------------------------------------- -4-C-121 Table 4-C-50.Cont.~._. ----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX - -------------------------~---~----------------------~------------------------ 820910 -820911 2330 -0533 6.2 6.3 6.3 6.9 7.2 7.5 820911 -820911 0534 -1137 6.1 6.2 .6.2 6.7 6.8 7.0 820911 -820911 1138 -1740 6.1 6.1 6.2 6.9 7.2 7.4 820911 820911 1741 2344 6.1 6.1 6.2 6.3 6.8 7.2 ~,-- 820911 -820912 2345 -0548 6.1 6.1 6.2 5.5 5.8 .6.2 -820912 -820912 0549 -1151 6.0 6.1 6.1 5.3 5.7 7.2 820912 -820912 1152 -1755 6.0 6.1 6.1 7.3 8.0 8.5 820912 ...820912 1756 -2359 6.1 6.1 6.1 6.4 6.8 7.5 820912 -820913 2400 -0602 6.1 6.1 6.2 5.9 6.2 6.4 820913 -820913 0603 -1206 6.1 6.1 6.1 5.8 5.9 6.1 820913 -820913 1207 -1810 6.0 6.1 6.1 5.9 6.4 .6.6 820913 -820914 1811 -0014 6.0 6.1 6.1 6.3 6.4 6.6 .~.- 820914 -820914 0015 -0617 6.1 6.1 6.1 6.1 6.3 6.4 820914 -820914 0618 -1221 6.0 6.0 6.1 6.1 6.2 6.5 ~I 820914 -820914 1222 -1825 6.0 6.0 6.0 6.5 6.7 6.8 820914 -820915 1826 -0028 6.0 6.0 6.0 6.6 6.7 6.8 820915 -820915 0029 -0632 6.0 6.0 6.0 6.3 6.5 6.6 820915 -820915 0633 -1236 6.0 6.0 6.1 6.3 6.6 7.3 820915 -820915 1237 -1839 6.0 6.0 6.1 7.3 8.1 8.4 ~ 820915 -820916 1840 -0043 6.0 6.1 6.1 7.4 7.6 8.0 ~i 820916 -820916 0044 -0647 6.0 6.0 6.1 7.3 7.4 7.4 820916 -820916 0648 -1251 5.9 5.9 6.0 7.3 7.4 7.8 820916 -820916 1252 -1854 6.0 6.0 6.0 7.6 8.0 8.1 820916 -820917 1855 -0058 6.0 6.0 6.0 7.0 7.2 7.6 820917 -820917 0059 -0702 5.9 6.0 6.0 6.7 6.9 7.0 -820917 -820917 0703 -1305 5.9 6.0 6.0 6.6 6.7 6.8 820917 -820917 1306 -1909 5.9 5.9 6.0 6.7 6.8 6.8 820917 --820918 1910 -0113 5.9 6.0 6.0 6.0 6.4 6.7 --------------------------------------------~--------------------------------- 4-C-122 ~. Table 4-C--50.Cont.,,-.. ~ ----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ------------------------------------------------~---------------------------- 820918 -820918 0114 -0716 5.9 6.0 6.0 5.6 5.8 6.0 820918 -820918 0717 -1320 5.8 5.9 6.0 5.5 5.8 6.4 820918 -820918 1321 -1924 5.9 5.9 5.9 6.4 6.7 6.8 820918 -820919 1925 -0128 5.9 5.9 5.9 5.9 6.3 6.6-820919 -820919 0129 ~0731 5.8 5.9 5.9 5.6 5.7 5.9 820919 -820919 0732 -1335 5.8 5.9 5.9 5.6 5.8 6.1 ~820919 -820919 1336 -1939 5.9 5.9 6.0 6.0 6.2 6.3 820919 -820920 1940 .;.0142 5.9 5.9 5.9 5.8 6.0 6.2 .-820920 -820920 0143 -0746 5.9 5.9 6.0 5.6 5.7 5.8 820920 -820920 0747 -1350 5.9 5.9 6.0 5.6 5.8 6.3 820920 -820920 1351 -1953 5.9 5.9 5.9 6.3 6.4 6.5 FA"'''' 820920 -820921 1954 -0157 5.9 5.9 5.9 5.6 6.0 6.3 820921 -820921 0158 -0801 5.9 5.9 6.0 5.4 5.5 5.6 820921 -820921 0802 -1405 5.9 5.9 6.0 5.4 5.6 5.9 820921 -820921 1406 -2008 5.9 5.9 5.9 5.9 6.1 6.2 820921 -820922 2009 -0212 5.9 5.9 6.0 5.6 5.8 6.1 820922 -820922 0213 -0816 5.9 6.0 6.0 5.3 5.4 5.6 -.820922 -820922 0817 -1419 5.9 6.0 6.0 5.3 5.4 5.9 820922 -820922 1420 -2023 5.9 6.0 6.0 5.9 6.3 6.5 820922 -820923 2024 -0227 6.0 6.0 6.1 4.7 5.2 5.9 820923 -820923 0228 -0830 6.0 6.0 6.0 3.9 4.3 4.6 820923 -820923 0831 -1434 5.9 6.0 6.0 3.9 4.5 5.6....820923 -820923 1435 -2038 5.9 6.0 6.1 5.3 5.7 5.9 820923 -820924 2039 -0242 6.0 6.1 6.1 3.8 4.5 5.4--820924 -820924 0243 -0845 6.0 6.1 6.1 2.9 3.3 3.8 820924 -820924 0846 -1449 6.0 6.0 6.1 2.9 3.7 4.9 820924 -820924 1450 -2053 6.0 6.1 6.1 4.9 5.1 5.2 820924 -820925 2054 -0256 6.1 6.1 6.2 4.2 4.6 5.0 ---------------------------~-------------------------------------------------- .-4-C-123 4-C-125 ~ Tab Ie 4-C-50.Cant.,,- 0- ----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX -----------------------------------------------------------------------------,.... I 821016 -821016 0204 -0807 5.7 5.8 5.8 1.3 1.6 1.8 82.1016 -82.1016 0808 -1411 5.6 5.7 5.7 1.1 1.5 1.8 821016 -821016 1412 -2015 5.6 5.7 5.7 1.0 1.3 1.6 821016 ...821017 2016 -0218 5.6 5.7 5.7 1.1 1.3 1.5 """821017 -82.1017 0219 -0822 5.6 5.7 5.7 1.4 1.6 1.8I 821017 -821017 0823 -1426 5.6 5.6 5.7 1.6 2.2 2.8 821017 -821017 1427 -2029 5.6 5.6 5.7 1.7 2.4 2.9 .- 821017 -821018 2030 -0233 5.6 5.6 5.6 1.1 1.6 1.8 821018 -821018 0234 -0837 5.6 5.6 5.6 1.1 1.3 1.7 821018 -821018 0838 -1440 5.5 5.6 5.6 .9 2.2 3.2 821018 -821018 1441 -2044 5.5 5.6 5.6 1.9 2.4 3.2 ~~-821018 -821019 2045 -0248 5.5 5.6 5.6 1.8 2.0 2.2 821019 -821019 0249 -0852 5.5 5.5 5.6 1.0 1.7 2.2 821019 -821019 0853 -1455 5.5 5.5 5.6 1.1 1.4 1.8 821019 -821019 1456 -2059 5.4 5.5 5.5 1.7 1.9 2.1 821019 -821020 2100 -0303 5.5 5.5 5.6 1.6 1.8 2.0 821020 -821020 0304 -0906 5.4 5.5 5.5 1.5 1.8 2.0 821020 -821020 0907 -1510 5.4 5.5 5.5 1.7 2.2 2.6 821020 -821020 1511 -2114 5.4 5.5 5.5 1.2 1.8 2.6 821020 -821021 2115 -0317 5.3 5.4 5.5 1.2 1.4 1.6 821021 -821021 0318 -0921 5.4 5.4 5.5 1.2 1.4 1.5 821021 -821021 0922 -1525 5.3 5.4 5.4 1.3 1.7 2.0 821021 -821021 1526 -2129 5.3 5.4 5.4 1.3 1.6 1.9 821021 -821022 2130 -0332 5.3 5.4 5.4 1.2 1.4 1.6-821022 -821022 0333 -0936 5.3 5.4 5.4 1.2 1.4 1.5 821022 -821022 0937 -1540 5.3 5.3 5.4 1.3 1.7 2.1 821022 -821022 1541 -2143 5.2 5.3 5.4 1.2 1.5 1.9 ~ 821022 -821023 2144 -0347 5.2 5.3 5.4 1.2 1.3 1.5 ...~ ----------------------------------------------------------------------------- 4-C-127 Table 4-C-50.Cant.'"'"I --" ----------------------------------------------------~------------------------ INTRAGRA VEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX.MIN MEAN MAX."'""----------------------------------------------------------------------------- 821023 -821023 0348 -0951 5.3 5.3 5.3 1.3 1.5 1.8 ~ 821023 -821023 0952 -1554 5.2 5.3 5.3 1.6 1.9 2.2 821023 -821023 1555 -2158 5.2 5.2 5.3 1.7 1.8 2.1 821023 -821024 2159 -0402 5.1 5.2 5.2 1.7 1.8 2.0 ~, 821024 -821024 0403 -1006 5.1 5.2 5.2 2.0 2.1 2.5 821024 -821024 1007 -1609 5.1 5.2 5.2 2.0 2.5 2.8 ~ 821024 -821024 1610 -2213 5.1 5.1 5.2 2.2-2.3 2.5 821024 -821025 2214 -0417 5.0 5.1 5.1 2.2 2.4 2.7 - 821025 -821025 0418 -1020 5.0 5.0 5.1 2.3 2.5 2.8 -------------------------------------------------------------~-------------- 4-C-128 .... - .... - Table 4-C-51.Datapod intragravel and surface water temperature (C)continuous record,at Slough SA-Upper,RM 126.4,Geocode S30N03W20CDD. Note.that time periods are 6 hours and 3 minutes and 42 seconds in duration;accordingly,daily minimum,maX1IDum and mean values can not be directly calculated from this data. ----------------------------------------------------------------------------- DATE PERIOD TIME PERIOD INTRAGRA VEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX ----------------------------------------------------------------------------- 820821 -820821 820821 -820821 820821 -820821 0001 -0604 0605 -1207 1208 -1811 4.7 4.7 4.7 4.7 4.7 4.8 4.8 4.8 4.8 5.0 5.0 6.5 5.2 5.3 8.5 5.5 6.4 9.4 820821 -820822 1812 -0015 4.7 4.8 4.8 5.4 6.0 7.2 820822 -820822 820822 -820822 820822 -820822 ,820822 -820823 820823 -820823 820823 -820823 820823 -820823 820823 -820824 820824 ;..820824 820824 -820824 820824 -820824 820824 -820825 820825 -820825 820825 -820825 820825 -820825 820825 -820826 820826 -820826 820826 -820826 820826 -820826 0016 -0619 0620 -1222 1223 -1826 1827 -0030 0031 -0633 0634 -1237 1238 -1841 1842 -0044 0045 -0648 0649 -1252 1253 -1856 1857 -0059 0100 -0703 0704 -1307 1308 -1910 1911 -0114 0115 -0718 0719 -1321 1322 -1925 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.8 4.8 4.7 4.8 4.8 4.8 4.7 4.8 4.7 4.8 4.8 4.7 4.7 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.9 4.9 5.0 6.4 5.8 5.6 5.7 6.2 5.6 5.4 5.5 6.4 5.8 5.6 5.5 6.0 5.6 5.5 5.7 6.1 5.1 5.3 8.1 6.1 5.8 6.3 7.2 5.9 5.6 6.0 7.6 6.0 5.7 6.1 7.3 5.8 5.6 6.4 8.1 5.4 6.3 9.3 6.8 5.9 7.2 7.7 6.3 5.8 7.3 8.5 6.4 5.9 6.8 8.6 6.2 5.7 8.1 9.7 820826 -820827 1926 -0129 4.7 4.8 4.9 5.3 5.7 6.3 -820827 -820827 820827 -820827 820827 -820827 0130 -:0733 0734 -13.36 1337 -1940 4.8 4.7 4.8 4.8 4.8 4.9 4.8 4.8 4.9 4.9 5.0 6.0 5.1 5.6 7.6 5.4 7.8 9.2 ~-~------------------------------------------------------------------------- 4-C-129 Table 4-C-Sl.Cont.~ ,,- ~ --------------------------------------------------------------~------~------- INTRAGRAVEL SURFACE WATER DATE TIME --------------------------~~---------~PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ---------------------------------------------------~------------------------- 820827 -820828 1941 -0144 4.8 4.8 4.9 5.4 5.7 6.2 820828 -820828 0145 -0747 4.8 4.8 4.8 5.1 5.3 5.5 820828 -820828 0748 -1351 4.8 4.8 4.9 5.4 5.9 6.5 820828 -820828 1352 -1955 4.8 4.8 4.9 6.0 7.1 8.2 820828 -820829 1956 -0158 4.8 4.8 4.9 5.6 5.8 6.0 820829 -820829 0159 -0802 4.8 4.9 4.9 5.6 5.7 5.8 820829 -820829 0803 -1406 4.8 4.9 4.9 5.7 6.1 6.5 820829 -820829 1407 -2010 4.8 4.9 4.9 6.0 6.3 6.5 ~. 820829 -820830 2011 -0213 4.9 4.9 4.9 5.7 5.8 6.1 820830 -820830 0214 -0817 4.9 4.9 4.9 5.7 5.7 5.8 -820830 -820830 0818 -1421 4.9 4.9 4.9 5.8 6.0 6.1 820830 -820830 1422 -2024 4.9 4.9 4.9 5.8 6.1 6.4 ~""'l 820830 -820831 2025 -0228 4.8 4.9 4.9 5.5 5.6 5.8 820831 -820831 0229 -0832 4.9 4.9 4.9 5.5 5 .6 5.6 820831 -820831 0833 -1435 4.8 4.9 4.9 5.6 6.0 6.4 820831 -820831 1436 -2039 4.8 4.9 4.9 5.6 6.1 6.7 820831 -820901 2040 -0243 4.9 4.9 4.9 5.6 5.7 5.8 - 820901 -820901 0244 -0847 4.8 4.9 4.9 5.7 5.9 6 .1 820901 -820901 0848 -1450 4.9 4.9 5.0 6.1 6.7 7.1 -820901 -820901 1451 -2054 4.9 4.9 5.0 6.1 6 .6 7.0 820901 -820902 2055 -0258 4.8 4.9 4.9 5.9 6.0 6.1 820902 -820902 0259 -0901 4.9 4.9 4.9 5.8 5.9 6.2 820902 -820902 0902 -1505 4.9 4.9 5.0 6.1 6 .6 7.5 820902 -820902 1506 -2109 4.9 4.9 5.0 6.2 6.7 7.6 820902 -820903 2110 -0312 4.9 4.9 5.0 5.9 6.1 6.3 -820903 -820903 0313 -0916 4.9 4.9 4.9 6.0 6.1 6.2 820903 -820903 0917 -1520 4.9 4.9 5.0 6.1 6.5 6.9 820903 -820903 1521 -2124 4.9 5.0 5.0 5.9 6.4 7.0 ----------------------------------------------------------------------------- 4-C-130 Table 4-C-51.Cont. --------~~----~-------------------------------------------------~---------INTRAGRA VEL SURFACE WATER r-DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------- 820903'-820904 2125 -0327 4.9 4.9 4.9 5.6 5.9 6.0 820904 -820904 0328 -0931 4.9 4.9 5.0 5.5 5.6 5.8 '"""820904 -820904 0932 -1535 4.9 4.9 5.0 5.5 6.5 7.1 820904 -820904 1536 -2138 4.9 5.0 5.0 5.6 6.4 7.1 820904 -820905 2139 -0342 4.9 4.9 5.0 5.2 5.5 5.9 820905 -820905 0343 -0946 4.9 5.0 5.0 5.3 5.5 5.9 820905 -820905 0947 -1549 4.9 5.0 5.0 5.8 6.5 6.8 820905 -820905 1550 -2153 5~0 5.0 5.0 5.9 6.3 6.7 820905 -820906 2154 -0357 5.0 5.0 5.0 5.6 5.8 5.9 820906 -820906 0358 -1001 4.9 5.0 5.0 5.4 5.6 6.0 820906 -820906 1002 -1604 5.0 5.0 5.0 5.9 6.2 6.4 ~,~.820906 -820906 1605 -2208 5.0 5.0 5.1 5.7 6.0 6.3 820906 -820907 2209 -0412 5.0 5.1 5.1 5.5 5.7 5.9 820907 -820907 0413 -1015 5.0 5.0 5.1 5.5 5.8 6.2 820907 -820907 1016 -1619 5.0 5.1 5.1 6.1 6.7 7.3 820907 -820907 1620 -2223 5.0 5.1 5.1 5.7 6.0 6.7 820907 -820908 2224 -0426 5.1 5.1 5.1 5.5 5.6 5.8 820908 -820908 0427 -1030 5.1 5.1 5.2 5.5 5.7 6.2 820908 -820908 1031 -1634 5.1 5.2 5.2 6.1 6.3 6.5 820908 -820908 1635 -2238 5.1 5.2 5.2 5.6 5.9 6.3 820908 -820909 2239 -0441 5.1 5.1 5.2 5.5 5.6 5.7 820909 -820909 0442 -1045 5.1 5.2 5.2 5.5 5.6 5.8 820909 -820909 1046 -1649 5.1 5.2 5.2 5.8 6.3 6.7 820909 -820909 1650 -2252 5.1 5.2 5.2 5.5 5.9 6.5 820909 -820910 2253 -0456 5.2 5.2 5.2 5.4 5.6 5.6 820910 -820910 0457 -1100 5.1 5.2 5.2 5.4 5.7 6.1 820910 -820910 1101 -1703 5.2 5.2 5.3 6.1 6.4 6.5 ~820910 -820910 1704 -2307 5.2 5.2 '5.3 5.4 5.8 6.3 .--, ----------------------------------------------------------------------------- ~4-C-131 4-C-132 - Table 4-C-51.Cont. ----------------------------------------------------------------------------- INT RAG RA VEL SURFACE WATER DATE TIME ------------------------------------ PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------- 820918 -820918 0052 -0654 5.1 5.2 5.2 5.3 5.4 5.5 ....820918 -820918 0655 -1258 5.1 5.1 5.2 5.4 5.9 6.5 820918 -820918 1259 -1902 5.1 5.2 5.2 6.1 6.3 6.5 820918 -820919 1903 -0106 5.1 5.1 5.2 5.6 5.8 6.1 820919 -820919 0107 -0709 5.1 5.1 5.1 5.5 5.5 5.6 820919 -820919 0710 -1313 5.1 5.1 5.2 5.5 5.7 6.0....820919 -820919 1314 -1917 5.1 5.2 5.2 5.7 5.9 6.0 820919 -820920 1918 -0120 5.1 5.1 5.1 5.5 5.6 5.7 ~ 820920 -820920 0121 -0724 5.1 5.1 5.1 5.5 5.5 5.6 820920 -820920 0725 -1328 5.1 5.1 5.1 5.5 5.8 6.1 820920 -820920 1329 -1931 5.1 5.2 5.2 5.7 6.0 6.2 1"""- 820920 -820921 1932 -0135 5.1 5.1 5.1 5.5 5.6 5.7 820921 -820921 0136 -0739 5.1 5.1 5.1 5.3 5.4 5.5 820921 -820921 0740 -1343 5.1 5.1 5.2 5.4 5.7 6.0 820921 -820921 1344 -1946 5.1 5.1 5.1 5.6 5.8 6.0 820921 -820922 1947 -0150 5.1 5.1 5.1 5.4 5.5 5.6 820922 -.820922 0151 -0754 .5.0 5.1 5.1 5.3 5.4 5.5 820922 -820922 0755 -1357 5.0 5.1 5.1 5.4 5.6 6.0 820922 -820922 1358 -2001 5.0 5.1 5.1 5.2 5.9 6.5 ....820922 -820923 2002 -0205 5.1 5.1 5.1 4.9 5.1 5.3 820923 -820923 0206 -0808 5.1 5.1 5.1 4.7 4.9 5.0 820923 -820923 0809 -1412 5.0 5.1 5.1 4.8 5.4 6.8 820923 -820923 1413 -2016 5.0 5.1 5.1 5.0 5.9 6.8 820923 -820924 2017 -0220 5.0 5.1 5.1 4.6 4.8 5.0 {!$i'IkJ 820924 -820924 0221 -0823 5.0 5.0 5.1 4.3 4.6 4.7 820924 -820924 0824 -1427 5.0 5.0 5.1 4.5 5.4 6.2 ,....820924 -820924 1428 -2031 5.0 5.1 5.1 5.2 5.6 6.0 /~820924 -820925 2032 -0234 5.0 5.0 5.•1 4.9 5.0 5.2 .....-------------------------------------------------------~--------------------- 4-C-133 Table 4-C-51.Cont. "c"-I'~ .- ----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER ~DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ------------------------------------------------------------------------~--- 821002 -821002 0419 -1022 4.8 4.8 4.9 4.8 4.9 5.1 821002 -821002 1023 -1625 4.8 4.8 4.9 5.1 5.7 5.9-821002 -821002 1626 -2229 4.8 4.8 4.9 4.7 5.1 5.6 821002 -821003 2230 -0433 4.8 4.8 4.8 4.8 4.9 4.9 821003 -821003 0434 -1036 4.8 4.8 4.8 4.7 4.8 4.9 821003 -821003 1037 -1640 4.8 4.8 4.8 4.9 5.4 5.9...821003 -821003 1641 -2244 4.7 4.8 4.8 4.7 5.1 5.5 821003 -821004 2245 -0448 4.7 4.8 4.8 4.5 4.6 4.8 ,....821004 -821004 0449 -1051 4.7 4.8 4.8 4.4 4.6 4.6 821004 -821004 1052 -1655 4.7 4.8 4.8 4.6 5.4 6.0 821004 -821004 1656 -2259 4.7 4.8 4.8 4.5 4.8 5.3 P-",.--.... 821004 -821005 2300 -0502 4.7 4.8 4.8 '4.3 4.5 4.6 821005 -821005 0503 -1106 4.7 4.7 4.8 4.3 4.5 4.7 821005 -821005 1107 -1710 4.7 4.7 4.8 4.6 5.3 5.8 821005 -821005 1711 -2313 4.7 4.7 4.8 4.6 4.7 5.0 821005 -821006 2314 -0517 4.7 4.7 4.8 4.3 4.5 4.6 821006 -821006 0518 -1121 4.7 4.7 4.8 4.3 4.6 5.0 i""'"821006 -821006 1122 -1725 4.7 4.7 4.7 5.0 5.2 5.4 821006 -821006 1726 -2328 4.6 4.7 4.7 4.7 4.8 5.1 821006 -821007 2329 -0532 4.7 4.7 4.7 4.7 4.7 4.7 I""" 821007 -821007 0533 -1136 4.7 4.7 4.7 4.5 4.6 4.7 821007 -821007 1137 -1739 4.7 4.7 4.7 4.6 4.8 5.1,.,..,821007 -821007 1740 -2343 4.7 4.7 4.7 4.6 4.7 4.8 821007 -821008 2344 -0547 4.7 4.7 4.7 4.0 4.4 4.6 821008 -821008 0548-1150 4.7 4.7 4.7 4.1 4.5 5.1 821008 -821008 1151 -1754 4.7 4.7 4.7 4.8 5.2 5.5 821008 -821008 1755 -2358 4.7 4.7 4.7 3.9 4.3 4.8 821008 -821009 2359 -0602 4.7 4.7 4.7 4.0 4.3 4.5 /"~ ~------------------------------------------------------------------------------ 4-C-135..... - ----------------------------------------------------------------------------- 4-C-138 Table 4-C-52.Datapod intrag'ravel and surface water temperature (C)continuous record,at Slough 9,RM 128.1,Geocode S30N03W09DBC. Note,that time periods are 6 hours and 3 minutes and 42 seconds in duration;accordingly,daily minimum,maxunum and mean values can not be directly calculated from this data. DATE PERIOD TIME PERIOD INTRAGRA VEL ' MIN MEAN MAX SURFACE WATER MIN MEAN MAX . ----------------------------------------------------------------------------- 820821 -820821 0604 -1207 820821 -820821 1208 -1811 3.4 3.5 3.5 3.6 3.5 3.7 5.1 6.9 9.5 9.6 11.0 12.0 820821 -820822 1812 -0015 3.5 3.6 3.6 7.5 9.4 11.1 ,.... 820822 -820822 820822 -820822 820822 -820822 0016 -0619 0620 -1222 1223 -1826 3.4 3.4 3.5 3.5 3.4 3.6 3.6 3.5 3.6 5.2 5.5 9.8 6.1 7.1 11.0 7.1 9.1 12.1 820822 -820823 820823 -820823 820823 -820823 820823 -820823 1827 -0030 0031 -0633 0634 -1237 1238 -1841 3.5 3.5 3.5 3.5 3.6 3.5 3.5 3.6 3.7 3.6 3.5 3.6 8.4 6.9 6.9 8.9 9.6 10.9 7.6 8.7 7.9 9.1 9.8 10.4 820824 -820825 1857 -0059 9.0 10.0 820823 -820824 820824 -820824 820824 -820824 820824 -820824 820825 -820825 820825 -820825 820825 -820825 820825 -820826 820826 -820826 820826 -820826 820826 -820826 820826 -820827 820827 -820827 820827 -820827 820827 -820827 820827 -820828 1842 -0044 0045 -0648 0649 -1252 1253 -1856 0100 -0703 0704 -1307 1308 -1910 1911 -0114 0115 -0718 0719 -1321 1322 -1925 1926 -0129 0130 -0733 0734 -1336 1337 -1940 1941 -0144 3.5 3.5 3.4 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.4 3.5 3.5 3.4 3.3 3.5 3.5 3.6 3.5 3.5 3.6 3.6 3.5 3.5 3.5 3.5 3.5 3.5 3.6 3.5 3.5 3.4 3.6 3.6 3.6 3.6 '3.5 3.1 3.6 :L5 3.5 ..3.6 3.6 3.6 3.5 3.7 3.6 3.5 3.6 3.7 3.7 7.8 6.5 6.5 9.1 8.1 6.7 6.7 8.5 7.3 6.0 6.2 9.2 6.8 4.5 4.8 9.3 6.6 8.8 7.1 7.6 10.3 7.4 7.7 9.3 8.3 6.8 8.0 10.6 8.4 5.6 7.3 11.0 8.2 9.5 8.2 9.5 11.5 8.5 9.1 10.4 9.6 7.4 10.6 12.1 10.2 7.0 10.2 11.6 10.2 4-C-139 Table 4-C-52.Cant.""""- ""'"----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DATE TIME --------------------------------------PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ---------------------------------------------------------------------------- 820828 -820828 0145 -0747 3.4 3.5 3.5 5.5 6.1 6.9 820828 -820828 0748 -1351 3.4 3.4 3.5 5.9 6.7 8.1 820828 -820828 1352 -1955 3.4 3.5 3.5 8.1 9.1 9.6 820828 -820829 1956 -0158 3.5 3.5 3.5 7.3 8.0 8.7 820829 -820829 0159 -0802 3.4 3.5 3.5 6.5 6.9 7.4 ~, 820829 -820829 0803 -1406 3.4 3.4 3.5 6.5 7.2 8.2 820829 -820829 1407 -2010 3.5 3.6 3.7 7.7 8.3 8.7 820829 -820830 2011 -0213 3.6 3.7 3.7 6.9 7.4 8.0 820830 -820830 0214 -0817 3.6 3.6.3.7 6.3 6.7 7.0 820830 -820830 0818 -1421 3.6 3.6 3.6 6.4 6.8 7.2 - 820830 -820830 1422 -2024 3.6 3.7 3.7 6.8 7.4 7.7 820830 -820831 2025 -0228 3.5 3.6 3.7 6.1 6.6 7.2 ~- 820831 -820831·0229 -0832 3.5 3.6 3.6 5.7 5.9 6.2 820831 -820831 0833 -1435 3.5 3.5 3.6 5.8 6.7 7.8 820831 -820831 1436 -2039 3.6 3.7 3.8 7.5 8.0 8.4 820831 -820901 2040 -0243 3.6 3.7 3.7 6.6 7.0 7.8 - 820901 -820901 0244 -0847 3.5 3.6 3.6 6.3 6.7 6.9 820901 -820901 0848 -1450 3.5 3.6 3.6 6.8 8.5 10.3 820901 -820901 1451 -2054 3.6 3.6 3.7 8.6 9.9 10.6 ~ 820901 -820902 2055 -0258 3.5 3.5 3.6 6.5 7.3 8.7 -.820902 -820902 0259 -0901 3.4 3.5 3.5 6.1 6.3 6.7 820902 -820902 0902 -1505 3.4 3.5 3.5 6.4 7.5 9.3 820902 -820902 1506 -2109 3.5 3.6 3.6 7.6 8.9 9.7 """"I ! 820902 -820903 2110 -0312 3.5 3.5 3.6 6.7 7.2 7.8 820903 -820903 0313 -0916 3.5 3.5 3.5 6.2 6.6 6.9 ~ 820903 -820903 0917 -1520 3.4 3.5 3.5 6.5 7.2 8.0 820903 -820903 1521 -2124 3.5 3.5 3.5,6.6 7.5 8.0 820903 --820904 2125 -0327 3.4 3.5 3.5 5.9 6.2 6.7 ----------------------------------------------------------------------------- 4-C-140 '""" Table4-C-52.Cont. -----~-----------------------------------------~----~-----------------------INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD,MIN MEAN MAX MIN MEAN MAX ~---------~-------------------------------------------------------------- ,~ 820904 -820904 0328 -0931 3.4 3.4 3.5 5.6 5.9 6.5 820904 -820904 0932 -1535 3.4 3.4 3.5 6.2 7.4 9.1 820904 -820904 1536 -2138 3.5 3.5 3.5 6.6 7.9 9.1 820904 -820905 2139 -0342 3.4 3.5 3.5 5.5 5.9 6.7 820905 -820905 0343 -0946 3.4 3.4 3.5 5.3 5.6 6.1 820905 -820905 0947 -1549 3.4 3.4 3.5 5.9 7.0 7.7 820905 -820905 1550 -2153 3.5 3.5 3.5 6.4 7.2 7.6 820905 -820906 2154 -0357 3.4 3.4 3.5 5.7 6.0 6.6 820906 -820906 0358 -1001 3.4 3.4 3.5 5.5 5.7 5,9 820906 -820906 1002 -1604 3.4 3.4 3.5 6.0 6.9 7.6 820906 -820906 1605 -2208 3.4 3.5 3.5 6.4 6.9 7.7 ~.'~" 820906 -820907 2209 -0412 3.4 3.4 3.5 5.8 6.1 6.5 ,....820907 -820907 0413 -1015 3.4 3.4 3.5 5.7 6.0 6.8 820907 -820907 1016 -1619 3.4 3.5 3.5 6.8 7.7 8.3 820907 ..820907 1620 -2223 3.5 3.5 3.5 6.7 7.4 8.2 ......820907 -820908 2224 -0426 3.4 3.4 3.5 5.9 6.2 6.7 820908 -820908 0427 -1030 3.4 3.5 3.5 5.7 5.9 6.4 820908 -820908 1031 -1634 3.4 3.5 3.5 6.4 7.2 7.7 820908 -820908 1635 -2238 3.5 3.5 3.5 6.6 7.1 7.7 820908 -820909 2239 -0441 3.4 3.5 3.5 5.7 6.1 6.6 820909 -820909 0442 -1045 3.4 3.4 3.5 5.6 5.8 6.4 820909 -820909 1046 -1649 3.4 3.4 3.5 6.2 7.3 8.2 820909 -820909 1650 -2252 3.4 3.4 3.5 6.3 7.2 8.1 820909 -820910 2253 -0456 3.4 3.4 3.5 5.7 6.1 6.7.,... 820910 -820910 0457 -1100 3.4 3.4 3.4 5.5 5.9 6.5 820910 -820910 1101 -1703 3.3 3.4 3.5 6.5 7.5 8.0 ,....820910 -820910 1704 -2307 3.4 3.4 3.5 6.1 7.0 8.0 820910 -820911 2308 -0511 3.4 3.4 3.4 5.4 5.8 6.4 ------------------------~---------------------------------------------------- -4-C-141 Table4-C-52.Cont.,- r- ----------------------------------------~------------~-----------------------INTRAGRA VEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ---------------------------~------------------------------------------------- 820918 -820918 0052 -0654 3.4 3.4 3.4 5.6 5.8 5.9 820918 -820918 0655 -1258 3.4 3.4 3.5 5.6 5.7 6.0 820918 -820918 1259 -1902 3.4 3.4 3.4 5.6 5.8 6.0\ 820918 -820919 1903 -0106 3.4 3.4 3.5 5.5 5.5 5.6 820919 -820919 0107 -0709 3.4 3.4 3.4 5.5 5.5 5.5 820919 -820919 0710 -131~3.4 3.4 3.4 5.5 5.6 5.9 820919 -820919 1314 -1917 3.4 3.4 3.5 5.7 5.8 5.9 820919 -820920 1918 -0120 3.4 3.5 3.5 5.6 5.7 5.1 820920 -820920 0121 -0724 3.4 3.4 3.4 5.6 5.7 5.7 820920 -820920 0725 -1328 3.4 3.4 3.5 5.6 5.9 6.2 820920 -820920 1329 -1931 3.4 3.4 3.5 6.2 6.3 6.4 ~.~"820920 -820921 1932 -0135 3.4 3.5 3.5 6.1 6.2 6 .3 820921 -820921 0136 -0739 3.4 3.5 3.5 6.0 6.1 6.2 820921 -820921 0740 -1343 3.4 3.4 3.5 6.0 6.4 6.7 820921 -820921 1344 -1946 3.4 3.4 3.5 6.2 6.4 6.5 820921 -820922 1947 -0150 3.4 3.5 3.5 5.9 6 .1 6.2 820922 -820922 0151 -0754 3.4 3.4 3.5 5.8 5.9 6.0 820922 -820922 0755 -1357 3.4 3.4 3.5 5.8 6.0 6.6 820922 -820922 1358 -2001 3.4 3.4 3.5 5.5 6.5 7.0 820922 -820923 2002 -0205 3.4 3.4 3.5 4.7 5.0 5.5 820923 -820923·0206 -0808 3.4 3.4 3.5 4.4 4.6 4.8 820923 -820923 0809 -1412 3.4 3.4 3.5 4.4 5.1 6.1 820923 -820923 1413 -2016 3.4 3.4 3.5 4.7 5.8 6.4 820923 -820924 2017 -0220 3.3 3.4 3.5 3.3 3.9 4.7 820924 -820924 0221 -0823 3.3 3.4 3.4 2.9 3.1 3.3 820924 -820924 0824 -1427 3.3 3.4 3.4 2.9 3.8 4.9 820924 -820924 1428 -2031 3.4 3.4 3.5 4.7 5.0 5.2 820924 -820925 2032 -0234 3.4 3.4 3.5 3.9 4.2 4.7 i~ P=---------------------------~------------------------------------------------- .-4-C-143 . """1 Table 4-C-52.Cont."""" "..,rc, ~, --------------------------------------------------------------------------~-- INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX .~ -------~-------------~--~----------------------------------------------- 821009 -821009 0603 -1205 3.2 3.2 3.2 2.5 2.7 2.9 821009 -821009 1206 -1809 3.2 3.2 3.3 3.0 3.4 3.6 821009 -821010 1810 -0013 3.3 3.3 3.3 3.2 3.4 3.5 821010 -821010 0014 -0616 3.3 3.3 3.3 3.0 3.1 3.2 821010 -821010 0617 -1220 3.2 3.3 3.3 2.9 3.0 3.1 821010 -821010 1221 -1824 3.2 3.3 3.3 3.1 3.2 3.3 821010 -821011 1825 -0027 3.2 3.3 3.3 2.9 3.1 3.2 821011 821011 0028 -0631 3.2 3.3 3.3 2.7 2.8 2.9 -',- 821011 -821011 0632 -1235 3.2 ~L2 3.2 2.6 2.7 2.8 821011 -821011 1236 -1839 3.2 3.2 3.2 2.6 2.9 3.0 ~ 821011 -821012 1840 -0042 3.2 3.2 3.2 2.4 2.6 2.6 821012 -821012 0043 -0646 3.1 3.2 3.2 2.2 2.2 2.3 AIIfiIY'- 821012 -821012 0647 -1250 3.1 3.1 3.2 2.2 2.4 2.6 821012 -821012 1251 -1853 3.1 3.2 3.2 2.6 2.8 3.0 821012 -821013 1854 -0057 3.2 3.2 3.2 2.8 2.9 3.0 ~ 821013 -821013 0058 -0701 3.2 3.2 3.2 2.5 2.6 2.9 821013 -821013 0702 -1304 3.1 3.2 3.2 2.5 2.5 2.5 1'IlJ!i!f~ 821013 -821013 1305 -1908 3.1 3.2 3.2 2.5 2.6 2.7 821013 -821014 1909 -0112 3.2 3.2 3.2 2.5 2.6 2.7 821014 -821014 0113 -0716 3.1 3.2 3.2 2.4 2.5 2.5 821014 -821014 0717 -1319 3.2 3.2 3.2 2.3 2.4 2.6 821014 -821014 1320 -1923 3.1 3.2 3.2 2.6 2.9 3.1 ""'" 821014 -821015 1924 -0127 3 .1 3 .2 3.2 2.0 2.4 2.8 821015 -821015 0128 -0730 3.1 3 .1 3.2 1.8 1.9 2.0 821015 -821015 0731 -1334 3.1 3 .1 3 .1 1.7 1.9 2.3 821015 -821015 1335 -1938 3 .1 3 .1 3 .1 2.3 2.5 2.5 ~ 821015 -821016 1939 -0141 3.1 3.1 3.2 2.1 2.2 2.4 821016 -821016 0142 ..0745 3.1 3.2 3.2 2.1 2.2 2.3 ,- -----------------------------------------------------------------------------~."'\ ~ 4-C-146 ""'" 4-C-147 -Table 4-C-52 Cont.,-. r- -----------------------------------------------------~-----------------------INTRAGRA VEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ---------~-~--------------------------------------------------------------- ~~ 821030 -821030 1113 -1716 2.5 2.6 2.6 1.1 1.1 1.2 821030 -821030 1717 -2320 2.5 2.5 2.6 1.1 1.1 1.1-821030 -821031 2321 -0523 2.6 2&6 2.6 1.1 1.1 1.1 821031 -821031 0524 -1127 2.6 2.6 2.6 1.1 1.1 1.2 821031 -821031 1128 -1731 2.6 2.6 2.6 1.1 1.1 1.2 821031 -821031 1732 -2335 2.6 2.6 2.6 1.1 1.2 1.2 -821031 -821101 2336 -0538 2.6 2.6 2.6 1.2 1.2 1.3 821101 -821101 0539 -1142 2.6 2.6 2.6 1.3 1.3 1.3 821101 -821101 1143 -1746 2.6 2.6 2.6 1.3 1.4 1.5.... 821101 -821101 1.51747-2349 2.6 2.7 2.7 1.5 1.6 821101 -821102 2350 -0553 2.7 2.7 2.7 1.6 1.7 1.7 ~~"'" 821102 -821102 0554 -1157 2.7 2.8 2.8 1.7 1.7 1.9 821102 -821102 1158 -1800 2.8 2.8 2.8 1.9 2.1 2.1 821102 -821103 1801 -0004 2.8 2.8 2.8 1.8 2.0 2.1 821103 -821103 0005 -0608 2.8 2.8 2.8 1.5 1.6 1.8 !"""821103 -821103 0609 -1212 2.8 2.8 2.8 1.4 1.5 1.5 821103 -821103 1213 -1815 2.8 2.8 2.8 1.5 1.7 1.7 821103 -821104 1816 -0019 2.8 2.8 2.8 1.7 1.7 1.7 821104 -821104 0020 -0623 2.8 2.8 2.8 1.6 1.7 1.7 ~821104 -821104 0624 -1226 2.8 2.8 2.8 1.6 1.7 1.9 821104 -821104 1227 -1830 2.8 2.8 2.9 1.9 2.0 2.1 821104 -821105 1831 -0034 2.8 2.9 2.9 1.7 1.8 1.9 ~ 821105 -821105 0035 -0637 2.8 2.8 2.8 1.5 1.6 1.7 821105 -821105 0638 -1241 2.8 2.8 2.8 1.5 1.6 1.8-821105 -821105 1242 -1845 2.8 2.8 2.9 1.8 1.9 2.0I 821105 -821106 1846 -0049 2.8 2.9 2.9 1.5 1.7 1.8 821106 -821106 0050 -0652 2.8 2.8 2.8 1.4 1.4 1.5 821106 -821106 0653 -1256 2.8 2.8 2.8 1.4 1.4 1.5 ----------------------------------------------------------------------------- 4-C-149 Table 4-C,.-S2 Cont.- ~.. ----------------------------------------------------------------------------- INTRAGRA VEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ~ ----------------------------------------~----------------------------------- 821106 -821106 1257 -1900 2.8 2.8 2.8 1.4 1.5 1.5 821106 -821107 1901 -0103 2.8 2.8 2.8 1.3 1.4 1.4 821107 -821107 0104 -0707 2.7 2.8 2.8 1.3 1.3 1.4 -821107 -821107 0708 -1311 2.7 2.7 2.7 1.3 1.3 1.4 821107 -821107 1312 -1914 2.7 2.7 2.7 1.3 1.4 1.4 -821107 -821108 1915 -0118 2.7 2.7 2.7 1.3 1.3 1.3 821108 -821108 0119 -0722 2.7 2.7 2.7 1.3 1.3 1.3 821108 -821108 0723 -1326 2.7 2.7 2.7 1.3 1.3 1.3 ..", , 821108 -821108 1327 -1929 2.6 2.7 2.7 1.2 1.3 1.3 821108 -821109 1930 -0133 2.6 2.7 2.7 1.2 1.2 1.2 - 821109 -821109 0134 -0737 2.6 2.6 2.7 1.2 1.3 1.3 821109 -821109 0738 -1340 2.6 2.6 2.7 1.3 1.3 1.4 ,~-; 821109 -821109 1341 -1944 2.6 2.7 2.7 1.3 1.4 1.4 821109 -821110 1945 -0148 2.7 2.7 2.7 1.4 1.4 1.5 -. 821110 -821110 0149 -0751 2.7 2.7 2.7 1.5 1.5 1.5 821110 -821110 0752 -1355 2.7 2.7 2.7 1.4 1.5 1.5 821110 -821110 1356 -1959 2.7 2.7 2.7 1.4 1.4 1.4 821110 -821111 2000 -0203 2.7 2.7 2.7 1.2 1.3 1.4 -821111 -821111 0204 -0806 2.6 2.6 2.7 1.1 1.2 1.2 821111 -821111 0807 -1410 2.6 2.6 2.6 1.1 1.2 1.4 821111 -821111 1411 -2014 2.6 2.6 2.6 1.3 1.4 1.5 821111 -821112 2015 -0217 2.6 2.6 2.7 1.5 1.5 1.5 821112 -821112.0218 -0821 2.6 2.7 2.7 1.5 1.5 1.6 ""'1 821112 -821112 0822 -1425 2.7 2.7 2.8 1.5 1.7 1.8 821112 -821112 1426 -2028 2.7 2.8 2.8 1.7 1.8 1.9 ~ 821112 -821113 2029 -0232 2.8 2.8 2.8 1.7 1.7 1.8 821113 -821113 0233 -0836 2.8 2.8 2.8 1.6 1.7 1.7 821113 -821113 0837 -1440 2.8 2.8 2.8 1.6 1.8 2.0 ~ ----------------------------------------------~----------------------------/,'.""'" ~ 4-C-lSO ~. -. Table 4-C-52.Cont. ---.._---------~------------------------------------~----------------------- DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX. 821113 -821113 1441 -2043 2.8 2.8 2.8 1.9 1.9 2.0 821113 -821114 2044 -0247 2.8 2.8 2.8 1.7 1.8 1.9 821114 -821114 0248 -0851 2.8 2.8 2.8 1.8 1.9 1.9 821114 -821114 0852 -1454 2.8 2.8 2.8 1.9 2.0 2.1 !"""821114 -821114 1455 -2058 2.8 2.9 2.9 1.7 2.0 2.2 ..... .... - ---_._----------------..-------------------------------------- 4-C-151 Table 4-C-53.Datapod intragravel and surface water temperature (C)continuous record.at Slough 11.RM 135.7.Geocode S31N02W30ADC. Note.that time periods are 6 hours and 3 minutes and 42 seconds in duration;accordingly,daily minimum,maximum and mean values can not be directly calculated from this data. -------------------------------~-------------~------~----------~-~~-------- DATE PERIOD TIME PERIOD INTRAGRA VEL--------..------.. MIN MEAN MAX, SURFACE WATER ~~----~~---~---- MIN MEAN MAX ----------------------------------------------- 820821 -820822 1812 -00~5 820822 -820823 1827 -0030 820821 -820821 820821 -820821 820821 -820821 820822 -820822 820822 -820822 820822 -820822 820823 -820823 820823 -820823 820823 -820823 820823 -820824 820824 -820824 820824 -820824 820824 -820824 820824 -820825 820825 -820825 820825 -820825 820825 -820825 820825 -820826 820826 -820826 820826 -820826 820826 -820826 820826 -820827 820827 -820827 820827 -820827 820827 -820827 0001 -0604 0605 -1207 1208 -1811 0016 -0619 0620 -1222 1223 -1826 0031 -0633 0634 -1237 1238 -1841 1842 -0044 0045 -0648 0649 -1252 1253 -1856 1857 -0059 0100 -0703 0704 -1307 1308 -1910 1911 -0114 0115 -0718 0719 -1321 1322 -1925 1926 -0129 0130 -0733 0734 -1336 1337 -1940 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.3 3.2 3.2 3.2 3.3 3.2 3.2 3.2 3.3 3.3 3.5 3.6 3.6 3.6 3.6 3.5 3.5 3.4 3.4 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.4 3.5 3.7 3.6 3.7 3.6 3.5 3.5 3.5 3.5 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.4 3.3 3.3 3.5 3.3 3.5 3.7 3.7 3.7 4.4 3.7 3.6 3.5 3.5 3.5 4.8 4.7 6.9 6.4 5.0 4.9 1.3 6.6 6.0 5.9 6.6 5.6 5.6 5.5 6.4 4.3 5.0 5.1 1.0 6.•2 5.7 3.6 3.5 3.4 3.4 3.4 3.4 5.3 5.4 8.4 1.6 5.5 5.7 8.4 7.4 6.3 6.2 7.1 6.1 5.6 6.0 7.5 6.1 5.7 6.2 8.0 7.0 6.0 5.5 3.6 3.5 3.5 3.4 3.5 5.9 6.9 9.2 8.7 6.3 7.3 9.0 8.4 6.6 6.6 7.3 6.8 5.8 7.0 8.0 7.3 6.0 7.2 8.4 1.7 ' 6.3 6.7 4.0 3.8 3.5 3.5 3.5 .... ..... ----~-----------------------------~---------~-----~----------~.------------- 4-C-152 Table 4-C-53.Cont. -------~----------------------------------------~--=-~~-----------=~~-~~~-INTRAGRAVEL SURFACE WATER DATE TIME ------------------------------~ PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX -----~------------'---~-------------------------------------------------~-~ 820827 -820828 1941 -0144 3.5 3.5 3.5 3.4 3.4 3.5 820828 -820828 0145 -0747 3.4 3.5 3.5 3.4 3.5 3.5 820828 -820828 0748 -1351 3.4 3.5 3.5 3.4 3.4 3.5 820828 -820828 1352 -1955 3.4 3.5 3.5 3.4 3.4 3.5 820828 -820829 1956 -0158 3.5 3.5 3.5 3.4 3.5 3.5 820829 -820829 0159 -0802 3.5 3.5 3.5 3.4 3.4 3.5 820829 -820829 0803 -1406 3.5 3.5 3.5 3.4 3.4 3.5 820829 -820829 1407 -2010 3.5 3.5 3.5 3.4 3.4 3.5 820829 -820830 2011 -0213 3.4 3.5 3.5 3.4 3.4 3.5 820830 -820830 0214 -0817 3.5 3.5 3.5 3.4 3.4 3.4 820830 -820830 0818 -1421 3.4 3.5 3.5 3.3 3.4 3.4 ~,~820830 -820830 1422 -2024 3.4 3.5 3.5 3.3 3.4 3.4 820830 -820831 2025 -0228 3.4 3.4 3.4 3.3 3.4 3.4-820831-820831 0229 -0832 3.4 3.4 3.4 3.4 3.4 3.4 820831 -820831 0833 -1435 3.4 3.4 3.5 3.3 3.4 3.4 820831 -820831 1436 -2039 3.4 3.5 3.5 3.3 3.4 3.4!""" 820831 -820901 2040 -0243 3.4 3.4 3.4 j-.3 3.4 3.4 ....820901 -820901 0244 -0847 3.4 3.4 3.4 3.3 3.4 3.4 820901 -820901 0848 -1450 3.4 3.4 3.5 3.3 3.4 3.4 820901 -820901 1451 -2054 3.4 3.5 3.5 3.3 3.4 3.5 820901 -820902 2055 -0258 3.4 3.5 3.5 3.4 3.4 3.5 820902 -820902 0259 -0901 3.4 3.5 3.5 3.4 3.4 3.4 820902 -820902 ,0902 -1505 3.4 3.4 3.5 3.3 3.4 3.4 820902 -820902 1506 -2109 3.4 3.5 3.5 3.4 3.4 3.5 820902 -820903 2110 -0312 3.4 3.5 3.5 3.4 3.4 3.5 820903 -820903 0313 -0916 3.4 3.4 3.5 3.4 3.4 3.4 I"""820903 -820903 0917 -1520 3.4 3.4 3.5 3.3 3.4 3.4 820903 -820903 1521 -2124 3.4 3.5 3.5 3.3 3.4 3.4,- ~ -------------~--------------------------------------------------------------- 4-C-153 ..... Table 4-C-53.Cont.,- ~ --------~--~------------------------------~--------------------------------INTRAGRA VEL SURFACE WATER F""DATE TIME ------------------------------ PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX-------.....------------.....----------------_._-------------- 820910 -820911 2308 -0511 3.4 3.4 3.4 3.3 3.3 3.3 820911 -820911 0512 -1115 3.3 3.4 3.4 3.3 3.3 3.3.....820911 -820911 1116 -1718 3.3 3.4 3.4 3.3 3.3 3.3 820911 -820911 1719 -2322 3.3 3.4 3.4 3.2 3.3 3.3 820911 -820912 2323 -0526 3.3 3.4 3.4 3.3 3.3 3.3 ~20912 -820912 0527 -1129 3.3 3.4 3.4 3.2 3.3 3.3 820912 -820912 1130 -1733 3.3 3.3 3.4 3.2 3.3 3.3 820912 -820912 1734 -2337 3.3 3.4 3.4 3.3 3.3 3.4 820912 -820913 2338 -0540 3.3 3.3 3.4 3.3 3.3 3.3 ~ 820913 -820913 0541 -1144 3.3 3.3 3.4 3.2 3.2 3.3 820913 -820913 1145 -1748 3.3 3.3 3.4 3.2 3.3 3.3 ""'",-820913 -820913 1749 -2352 3.3 3.4 3.4 3.2 3.3 3.3 820913 -820914 2353 -0555 3 .3 3.4 3.4 3.3 3.3 3.3-820914 -820914 0556 -1159 3.3 3.3 3.4 3.2 3 .3 3.3 820914 -820914 1200 -1803 3.3 3.3 3.4 3.2 3.3 3.3 ....820914 -820915 1804 -0006 3.3 3.4 3.4 3.2 3.3 3.3 820915 -820915 0007 -0610 3.3 3.4 3.4 3.3 3.3 3.3 820915 -820915 0611 -1214 3.3 3.3 3.4 3.2 3.3 3.3 820915 -820915 1215 -1817 3.3 3.4 3.4 3.3 3.3 3.3 820915 -820916 1818 -0021 3.3 3-.4 3.4 3.2 3.3 3.4 820916 -820916 0022 -0625 3.3 3.4 3.4 3.2 3.3 3.4 820916 -820916 0626 -1229 3.3 3.4 3.4 3.2 3.3 3.3-820916 -820916 1230 -1832 3.3 3.3 3.4 3.2 3.3 3.3 820916 -820917 1833 -0036 3.3 3.4 3.4 3.3 3.3 3.4 820917 -820917 0037 -0640 3.3 3.3 3.4 3.2 3.3 3.3 820917 -820917 0641 -1243 3.3 3.3 3.3 3.2 3.3 3.3 820917 -820917 1244 -1847 3.3 3.3 3.4 3.2 3.3 3.3..... 820917 -820918 1848 -0051 3.3 3.3 3.4 3.2 3.2 3.3 ---------------------------------------------------------------------------- 4-C-155 Table 4-C-53.Cant. 4-C-157 f"'" Table 4-C-53.Cont • _fi~ ...., --------~~--~-------------------------------~----~-------------~---------INTRAGRA VEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX.MIN MEAN MAX -----------------~---------------------~~-------------------------------- 821009 -821009 0603 -1205 3.1 3.2 3.2 3.1 3.1 3.2 821009 -821009 1206 -1809 3.2 3.2 3.3 3.1 3.1 3.1-I 821009 -821010 1810 -0013 3.2 3.2 3.3 3.1 3.1 3.2 821010 -821010 0014 -0616 3.2 3.2 3.2 3.1 3.1 3.1 821010 -821010 0617 -1220 3.2 3.2 3.3 3.1 3.1 3.1 821010 -821010 1221 -1824 3.2 3.2 3.3 3.1 3.1 3.2 ~ 821010 -821011 1825 -0027 3.2 3.2 3.3 3.1 3.1 3.2 821011 -821011 0028 -0631 3.2 3.2 3.3 3.1 3.1 3.1-821011 -821011 0632 -1235 3.2 3.2 3.3 3.1 3.1 3.1 821011 -821011 1236 -1839 3.2 3.2 3.3 3.1 3.1 3.1 ~""'~'821011 -821012 1840 -0042 3.2 3.2 3.2 3.1 3.1 3.1 821012 -821012 0043 -0646 3.2 3.2 3.2 3 .1 3.1 3 .1 821012 -821012 0647 -1250 3 .1 3.2 3.2 3 .1 3.1 3.1 821012 -821012 1251 -1853 3.1 3.2 3.2 3 .1 3 .1 3.1 821012 -821013 1854 -0057 3.2 3.2 3.2 3.1 3 .1 3.1.- 821013 -821013 0058 -0701 3.2 3.2 3.2 3:1 3.1 3.1 821013 -821013 0702 -1304 3.2 3.2 3.2 3.1 3.1 3.1-821013 -821013 1305 -1908 3.2 3.2 3.2 3.1 3.1 3.1 821013 -821014 1909 -0112 3.2 3.2 3.2 3.1 3.1 3.1 ~821014 -821014 0113 -0716 3.2 3.2 3.3 3.0 3.1 3.1 821014 -821014 0717 -1319 3.1 3.2 3.3 3.0 3.1 3.1 821014 -821014 1320 -1923 3.1 3.2 3.2 3.1 3.1 3.2 821014 -821015 1924 -0127 3.2 3.2 3.3 3.0 3.1 3.2 r-821015 -821015 0128 -0730 3.1 3.2 3.3 3.0 3.1 3.1 821015 -821015 0731 -1334 3.1 3.2 3.2 3.0 3.1 3.1 821015 -821015 1335 -1938 3.1 3.2 3.3 3.0 3.1 3.1 821015 -821016 1939 -0141 3.2 3.2 3.2 3.0 3.1 3.1 ----------------------------------------------------------------------------- -4-C-159 ~ Table 4-C-53.Cont. ~ 1""1'" -----------------------------------------------------------------------------""'" INTRAGRA VEL SURFACE WATER DATE TIME ------------~----------~~---------PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ~------------------------------------------------------- 821016 -821016 0142 -0745 3.2 3.2 3.2 3.0 3.1 3.1 821016 -821016 0746 -1349 3.2 3.2 3.2 3.0 3.1 3.1 821016 -821016 1350 -1953 3.2 3.2 3.2 3.0 3.1 3.1 821016 -821017 1954 -0156 3.2 3.2 3.2 3.0 3.0 3.1 821017 -821017 0157 -0800 3.2 3.2 3.2 3.0 3.1 3.1 821017 -821017 0801 -1404 3.1 3.2 3.2 3.0 3.1 3.1 821017 -821017 1405 -2007 3.1 3.2 3.2 3.0 3.1 3.1 821017 -821018 2008 -0211 3.2 3.2 3.3 3.0 3.1 3.1 ~, 821018 -821018 0212 -0815 3.2 3.2 3.2 3.0 3.1 3.1 821018 -821018 0816 -1418 3.1 3.2 3.2 3.0 3.1 3.1 821018 -821018 1419 -2022 3.1 3.2 3.2 3.0 3.1 3.1 ~ 821018 -821019 2023 -0226 3.2 3.2 3.2 3.1 3.1 3.1 821019 -821019 0227 -0830 3.2 3.2 3.2 3.1 3.1 3.1 ~.-i 821019 -821019 0831 -1433 3.2 3.2 3.2 3.0 3.1 3.1 821019 -821019 1434 -2037 3.1 3.2 3.2 3.0 3.1 3.1 821019 -821020 2038 -0241 3.2 3.2 3.2 3.0 3.1 3.1 821020 -821020 0242 -0844 3.2 3.2 3.2 3;0 3.1 3.1 821020 -821020 0845 -1448 3.1 3.2 3.2 3.0 3.1 3.1 821020 -821020 1449 -2052 3.1 3.2 3.2 3.0 .3.1 3.1 821020 -821021 2053 -0255 3.2 3.2 3.2 3.0 3.1 3.1 821021 -821021 0256 -0859 3.1 3.2 3.2 3.0 3.1 3.1 821021 -821021 0900 -1503 3.1 3.2 3.2 3.0 3.1 3.1 821021 -821021 1504 -2107 3.1 3.2 3.2 3.0 3.0 3.1 821021 -821022 2108 -0310 3.1 3.1 3.2 3.0 3.0 3.0 821022 -821022 0311 -0914 3.1 3.1 3.2 2.9 3.0 3.0 821022 -821022 0915 -1518 3.1 3.1 3.2 2.9 3.0 3.0 821022 -821022 1519 -2121 3.1 3.1 3.2 2.9 3.0 3.0 II!lFlI1 821022 -821023 2122 -0325 3.1 3.1 3.2 2.9 3.0 3.0 ~ -------------------------------------~--------------------------------------- 4-C-160 -Table 4-C-53 .Cont • [,"'""- ----------------------------------------------------------------------------- INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ..-...--------------------------------~--------------------------------- ~ 821023 -821023 0326 -0929 3.1 3.1 3.2 3.0 3.0 3.0 821023 -821023 0930 -1532 3.1 3.1 3.2 2.9 3.0 3.0 821023 -821023 1533 -2136 3.1 3.1 3.2 2.9 3.0 3.0 821023 -821024 2137 -0340 3.1 3.1 3.2 3.0 3.0 3.0 821024 -821024 0341 -0944 3.1 3.1 3.2 3.0 3.0 3.0 821024 -821024 0945 -1547 3.1 3.1 3.2 2.9 3.0 3.1 821024 -821024 1548 -2151 3.1 3.1 3.2 2.9 3.0 3.1 ~ 821024 -821025 2152 -0355 3.1 3.2 3.2 3.0 3.0 3.0 821025 -821025 0356 -0958 3.1 3.1 3.2 2.9 3.0 3.0 ~821025 -821025 0959 -1602 3.1 3.1 3.2 2.9 3.0 3.1 821025 -821025 1603 -2206 3.1 3.1 3.2 2.9 3.0 3.0 ~~"821025 -821026 2207 -0409 3 .1 3.1 3.2 2.9 3.0 3.0 821026 -821026 0410 -1013 3 .1 3 .1 3.1 3.0 3.0 3.0 .....821026 -821026 1014 -1617 3.1 3.1 3.2 2.9 3.0 3.0 821026 -821026 1618 -2221 3.1 3.1 3.2 2.9 3.0 3.0 821026 -821027 2222 -0424 3.1 3.1 3.2 2.9 3.0 3.0 821027 -821027 0425 -1028 3.1 3.1 3.1 2.9 3.0 3.0 ~~---------------------------------------------------------------------- 4-C-161 Table 4-C-54.Datapod intragrave1 and surface water temperature (C)continuous record.at Slough 16B.RM 138.0,Geocode S31N02W17AAA. Note,that time periods are 6 hours and 3 minutes and 42 _ seconds in duration;accordingly,daily minimum,maximum and mean values can not be directly calculated from this data."-'------------------------------------------------------------------------------ DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX ---------------------------------------------------------------------~------- 820821 -820821 820821 -820821 820821 -820821 820821 -820822 820822 -820822 820822 -820822 820822 -820822 0001 -0604 0605 -1207 1208 -1811 1812 -0015 0016 -0619 0620 -1222 1223 -1826 5.0 4.8 5.4 5.6 4.8 4.7 5.5 5.4 5.0 6.2 6.2 5.2 4.9 6.3 5.7 5.4 6.7 6.6 5.6 5.5 6.9 4.4 4.3 6.3 5.1 4.2 4.2 6.2 4.8 5.1 7.9 6.2 4.6 5.0 7.7 5.3 6.4 9.2 7.4 5.1 6.4 9.0 820822 -820823 1827 -0030 5.9 6.3 6.7 5.8 6.4 7.4 820823 -820823 820823 -820823 820823 -820823 0031 -0633 0634 -1237 1238 -1841 5.6 5.6 6.3 5.7'5.9 5.9 6.4 6.7 6.8 5.5 5.6 6.9 5.7 6.3 7.3 5.9 7.1 8.0 - 820823 -820824 1842 -0044 820825 -820826 1911 -0114 820824 -820824 820824 -820824 820824 -820824 820824 -820825 820825 -820825 820825 -820825 820825 -820825 820826 -820826 820826 -820826 820826 -820826 820826 -820827 820827 -820827 820827 -820827 820827 -820827 0045 -0648 0649 -1252 1253 -1856 1857 -0059 0100 -0703 0704 -1307 1308 -1910 0115 -0718 0719 -1321 1322 -1925 1926 -0129 0130 -0733 0734 -1336 1337 -1940 5.7 5.4 5.4 6.6 6.1 5.9 5.9 6.8 6.2 5.9 5.9 6.8 5.6 4.6 4.6 6.1 6.1 5.5 5.9 7.1 6.6 6.0 6.3 7.1 6.6 6.0 6.3 7.2 6.4 5.1 5.2 6.8 6.7 5.7 6.6 7.4 7.0 6.2 6.8 7.5 7.1 6.2 6.8 7.6 7.1 5.6 6.1 7.4 5.5 5.1 5.2 7.1 5.8 5.5 5.7 6.9 5.8 5.5 5.6 7.2 4.8 3.9 4.0 6.3 6.0 5.3 6.2 7.8 6.4 5.8 6.6 7.9 6.4 5.7 6.8 8.1 5.8 4.3 5.3 7.5 6.8 5.5 7.6 8.7 7.3 6.0 7.8 9.0 7.1 6.0 8.0 9.1 7.2 4.8 6.9 8.7 ~.- - -., - 4-C-162 4-C 163 4-C-165 Table 4-C-54.Cont. ~t --------------------------------------~----------------------~--~----~--~---INTRAGRAVEL SURFACE WATER DATE TIME --------------------------------------"""! PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX. ----------------------------------~---~---------~--------------------------~ 820918 -820918 0052 -0654 5.7 5.8 5.9 5.6 5.7 5.8 820918 -820918 0655 -1258 5.5 5.6 5.7 5.5 5.9 6.4 820918 -820918 1259 -1902 5.5 5.5 5.6 6.4 6.5 6.6 820918 -820919 1903-0106 5.4 5.5 5.6 6.1 6.3 6.5 ~ 820919 -820919 0107 -0709 5.3 5.4 5.5 6.0 6.0 6.1 820919 -820919 0710 -1313 5.2 5.3 5.4 5.9 6.1 6.3 820919 -820919 1314 -1917 5.2 5.3 5.4 6.3 6.4 6.5 - 820919 -820920 1918 -0120 5.2 5.3 5.3 6.0 6.1 6.4 820920 -820920 0121 -0724 5.1 5.2 5.3 5.7 5.8 6.0 .~ 820920 -820920 0725 -1328 5.0 5.1 5.2 5.7 6.0 6.4 820920 -820920 1329 -1931 5.1 5.1 5.2 6.2 6.4 6.5 ..... 820920 -820921 1932 -013~5.0 5.1 5.1 5.8 5.9 6.2 820921 -820921 0136 -0739 4.9 5.0 5.1 5.5 5.7 5.8 820921 -820921 0740 -1343 4.9 4.9 5.0 5.6 5.9 6.3 820921 -820921 1344 -1946 4.9 5.0 5.1 6.2 6.3 6.4 820921 -820922 1947 -0150 4.9 5.0 5.0 5.8 6.0 6.2 820922 -820922 0151 -0754 4.9 5.0 5.1 5.4 5.6 5.8 820922 -820922 0755 -1357 4.7 4.8 4.9 5.5 .5.8 6.2 820922 -820922 1358 -2001 4.7 4.8 4.8 4.7 5.9 6.5 820922 -820923 2002 -0205 4.6 4.7 4.9 3.9 4.1 4.7 ~ 820923 -820923 0206 -0808 4.4 4.5 4.6 3.2 3.7 4.0 820923 -820923 0809 -1412 4.1 4.3 4.4 3.2 4.2 5.5 820923 -820923 1413 -2016 4.2 4.4 4.5 3.7 5.0 5.8 - 820923 -820924 2017 -0220 4.2 4.4 4.6 2.6 3.0 3.6 """820924 -820924 0221 -0823 3.9 4.1 4.3 2.3 2.5 2.7 820924 -820924 0824 -1427 3.8 3.9 4.0 2.5 4.2 5.6 820924 -820924 1428 -2031 4.0 4.2 4.4 4.4 5.2 5.7 ~ 820924 -820925 2032 -0234 4.2 4.3 4.4 3.3 3.7 4.4 ---------------------------------------------------~------~------------------~ 4-C-166 Table 4-C-54.Cont.- ""--------------------------------------------------------~--------------------- INTRAGRAVEL SURFACE WATER DATE TIME --------------------------------------, PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------- .-820925 -820925 0235 -0838 4.0 4.1 4.2 2.7 3.0 3.5 820925 -820925 0839 -1442 3.7 3.9 4.1 2.9 4.6 5.7 820925 -820925 1443 -2045 4.1 4.3 4.5 4.7 5.3 5.8 .... 820925 -820926 2046 -0249 4.4 4.4 4.5 4.0 4.4 4.7 820926 -820926 0250 -0853 4.2 4.3 4.5 4.0 4.1 4.2 820926 -820926 0854 -1457 4.2 4.3 4.4 4.1 4.9 5.5 820926 -820926 1458 -2100 4.4 4.5 4.6 4.5 4.8 5.3 r-820926 -820927 2101 -0304 4.4 4.5 4.6 4.3 4.4 4.5 820927 -820927 0305 -0908 4.3 4.4 4.5 4.2 4.2 4.3 820927 -820927 0909 -1511 4.3 4.4 4.5 4.3 5.0 5.9 I!""820927 -820927 1512 -2115 4.5 4.6 4.8 3.6 4.9 6.3 820927 -820928 2116 -0319 4.2 4.4 4.7 2.7 3.1 3.6 4~, 820928 -820928 0320 -0922 3.7 4.0 4.2 2.6 2.7 3.2 820928 -820928·0923 -1526 3.8 3.9 4.1 3.2 4.4 5.0 820928 -820928 1527 -2130 4.1 4.2 4.3 4.2 4.4 4.8 820928 -820929 2131 -0334 4.2 4.2 4.3 4.0 4.1 4.2 .-820929 -820929 0335 -0937 4.1 4.2 4.3 3.9 4.0 4.2 82092 9 -820929 0938 -1541 4.1 4.3 4.5 4.2 5.2 6.0 820929 -820929 1542 -2145 4.5 4.6 4.7 4.6 5.1 5.8 820929 -820930 2146 -0348 4.6 4.6 4.7 4.2 4.5 4.6 820930 -820930 0349 -0952 4.4 4.5 4.6 4.0 4.1 4.4 820930 -820930 0953 -1556 4.4 4.5 4.7 4.4 5.4 6.1 820930 -820930 1557 -2159 4.7 4.8 4.9 4.5 .5.0 5.7 820930 -821001 2200 -0403 4.6 4.7 4.8 4.1 4.3 4.6 821001 -821001 0404 -1007 4.4 4.5 4.6 3.9 4.1 4.2-821001 -821001 1008 -1611 4.4 4.5 4.6 4.3 4.9 5.4 821001 -821001'1612 -2214 4.6 4.6 4.7 3.7 4.3 5.2 821001 -821002 2215 -0418 4.3 4.5 .4.6 3.6 3.7 3.8 ~ -----------------------------------------------------------------------------,.-., 4-C-167 Table 4-C-54.Cont. 8JiilIlllI ------------------------------~----------------------------------------------Aliff" INTRAGRAVEL SURFACE WATER DATE TI~--------------------...-------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX -------------------.----------~----~-~--------------------------~----------- 821002 -821002 0419 -lOP 4.1 4.3 4.3 3.6 3.7 4.4 821002 -821002 1023 -1625 4.2 4.4 4.6 4.3 5.2 5.6 ~ 821002 -821002 1626 -2229 4.6 4.7 4.8 3.9 4.6 5.4 821002 -821003 2230 -0433 4.3 4.5 '4.7 3.4 3.7 4.0 821003 -821003 0434 -1036 4.1 4.2 4.4 3.4 3.6 4.4 821003 -821003 1037 -1640 4.1 4,,3 4.5 4.3 5.0 5.3 821003 -821003 1641 -2244 4.5 4.6 4.6 3.4 4.2 5.1 """' 821003 -821004 2245 -0448 4.0 4.3 4.5 2.5 2.9 3.5 821004 -821004 0449 -1051 3.5 3.8 4.1 2.3 2.5 2.9 821004 -821004 1052 -1655 3.5 3.6 3.9 2.9 4.1 4.7 821004 -821004 1656 -2259 3.9 4.0 4.1 2.6 3.1 4.1 821004 -821005 2300 -0502 3.5 3 .7 3.9 2.5 2.7 2.7 821005 -821005 0503 -1106 3.3 3.5 3.5 2.3 2.5 2.9 ~""~ 821005 -821005 1107 -1710 3 .3 3.4 3.6 2.9 3.7 4.1 821005 -821005 1711 -2313 3.5 3.6 3.8 2.2 2.8 3.7 ..,. 821005 -821006 2314 -0517 3.2 3.3 3.5 2.0 2.1 2.4 821006 -821006 0518 -1121 2.9 3.1 3.2 2.0 2.5 3.3 821006 -821006 1122 -1725 3.0 3.3 3.6 3.1 3.9 4.4 821006 -821006 1726 -2328 3.6 3.6 3.7 3.0 3.3 3.7 821006 -821007 2329 -0532 3.4 3.5 3.6 2.7 2.9 3.0 ~ 821007 -821007 0533 -1136 3.3 3.4 3.5 2.7 2.9 3.1 821007 -821007 1137 -1739 3.3 3.5 3.7 3.1 3.7 4.1 ~821007 -821007 1740 -2343 3.6 3.7 3.7 2.8 3.3 3.7 821007 -821008 2344 -0547 3.4 3.5 3.7 2.7 2.9 3.1 821008 -821008 0548 -1150 3.4 3.5 3.5 2.8 3.2 3.9 ,821008 -821008 1151 -1754 3.4 3.7 3.9 3.6 4.1 4.5 821008 -821008 1755 -2358 3.5 3.8 3.9 2.0 2.8 3.6 - 821008 -821009 2359 -0602 3.2 3.3 3.5 2.1 2.4 2.8 ,~----------------------------------------------------------------------------- /Af!fE!..t;:",\- 4-C-168 4-C-169 Table 4-C-54.Cont. - ---------------------------------~-----------------~--~--------~------------~ INTRAGRAVEL SURFACE WATER DATE TIME """-~----------------------~-----------l'ERIOD l'ERIOD MI~MEAN MAX MIN MEAN MAX ---~-----------------------------~--~------~--------~--~---.-~----------- 821016 ...821016 0142 ...0745 3.0 3.1 3.2 2.7 2.9 3.1 821016 ...821016 0746 ...1349 3.1 3.t 3.2-2.7 2.9 3.1 821016 ...821016 1350 -1953 3.1 3.1 3.2 2.7 2.8 3.0 821016 ...821017 1954 ...0156 3.0 3.1 3.2 2.2 2.6 2.9 821017 ...821017 0157 ...0800 3.0 3.1 3.2 2.8 3.0 3.2 821017 ...821017 0801 ...1404 3.1 3.3 3.5 3.0 3.4 3.8 821017 ...821017 1405 "2007 3.4 3.5 3.6 2,.7 3.2 3.8 821017 ...821018 2008 ...0211 3.2 3.4 3.5 2.4 2.6 2.8 821018 ...821018 0212 ...0815 3.1 3.2 3.3 2.3 2.5 2.7 821018 821018 0816 1418 3.0 3.1 3.2 2.6 3.1 3.4 .....,...... 821018 ...821018 1419 -2022 3.2 3,.3 3.3 2.7 2.9 3.3 821018 ...821019 2023 ...0226 3.2 3.3 3.3 2.7 2.9 3.0 ..... 821019 ...821019 0227 ...0830 3.1 3>.2 ,3.3 2.1 2.6 3.0 821019 ...821019 0831 ...1433 2,.9 3.0 3.1 2.3 2.8 3.2 ._""'!1 821019 ...821019 143.4 ...2037 3.0 3.2-3.3 2.8 3.0 3.3 821019 ...821020 2038 ...0241 3.2 3.3 3.4 2.5 2.8 3.0 ~ 821020 ...821020 0242 ...0844 3.•1 3.,2 3.3 2.6 2.7 2.9 821020 ...821020 0845 ...1448 3.l 3.2 3.3 2•.7 3.1 3.5 821020 ...821020 1449 ...2052 3.?-3,.3 3.4 2.6 2.8 3'.2 ~ 821020 ...821021 2053 ...0255 3.1 3.2 3.3 2.6 2.7 2.8 """821021 ...821021 0256 ...0859 3.1 3.1 3.2 2.6 2.7 2.8 821021 ...821021 0900 ...1503 3.0 3.1 3.1 2.7 2.9 3.2 821021 ...821021 1504 -2107 3.•0 3.2 3.2 2.3 2.6 3.0 ~ 821021 ...821022 2108 ...0310 '2.9 3.0 3.1 2.2 2.4 2.6 821022 ...821022 0311 ...0914 2.7 2.8 2.9 2.0 2.3 2.6 821022 ...821022 0915 ...1518 2,.6 2.•8 3.1 2.5 3.1 3.4 821022 ...821022 1519 -2121 3.1 3.3 3.4 2.5 2.9 3.3 ~ 821022 ...821023 2122 ...0325 3.1 3.2 3.2 2.5 2.8 3.0 ~ ------------------------------------~--------~,----------~--~~-----~------- 4-C-170 Table4-C-54.Cont.,... ,~~ -----------------------------------------------------------------------------,.... INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------- 821023 -821023 0326 -0929 3.0 3.2 3.3 2.4 2.7 2.9 821023 -821023 0930 -1532 2.9 3.0 3.2 2.7 3.0 .3.2 821023 -821023 1533 -2136 3.1 3.2 3.3 2.7 2.8 3.2 821023 -821024 2131 -0340 3.0 3.2 3.2 2.6 2.7 2.8 821024 -821024 0341 -0944 3.0 3.1 3.1 2.6 2.8 2.9 821024 -821024 0945 -1547 3.0 3.1 3.4 2.9 3.2 3.6 821024 -821024 1548 -2151 3.3 3.5 3.5 2.5 2.9 3.4 821024 -821025 2152 -0355 2.8 3.1 3.4 2.2 2.4 2.7 821025 -821025 0356 -0958 2.7 2.8 2.9 2.2 2.6 3.0 -. """ - 4-C-171 Table 4-C-55.Datapod intragrave1 and surface water temperature (C)continuous record,at Slough 19,RM 140.0,Geocode S31N02W10DBA. Note,that time periods are 6 hours and 3 minutes and 42 seconds in duration;accordingly,daily minimum,maximum and mean values can not be directly calculated from this data. -------------------------------------~--------------------------------------- DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX - 820821 -820821 820821 -820821 820821 -820821 820821 -820822 820822 -820822 820822 -820822 820822 -820822 820822 -820823 820823 -820823 820823 -820823 820823 -820823 820823 -820824 820824 -820824 820824 -820824 820824 -820824 820824 -820825 820825 -820825 820825 -820825 820825 -820825 820825 -820826 820826 -820826 820826 -820826 820826 -820826 820826 -820827 820827 -820827 820827 -820827 820827 -820827 0001 -0604 0605 -1207 1208 -1811 1812 -0015 0016 -0619 0620 -1222 1223 -1826 1827 -0030 0031 -0633 0634 -1237 1238 -1841 1842 -0044 0045 -0648 0649 -1252 1253 -1856 1857 -0059 0100 -0703 0704 -1307 1308 -1910 1911 -0114 0115 -0718 0719 -1321 1322 -1925 1926 -0129 0130 -0733 0734 -1336 1337 -1940 2.9 2.8 2.8 2.9 3.0 2.8 2.8 2.9 3.0 2.9 2.9 3.0 2.9 2.9 3.0 3.0 3.0 3.0 3.1 3.0 2.9 2.9 3.0 3.0 2.9 2.9 2.9 2.9 2.9 3.0 3.0 2.9 2.9 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.1 3.1 3.0 3.0 3.1 3.0 3.0 3.0 3.1 3.0 2.9 2.9 3.0 2.9 3.0 3.1 3.0 2.9 3.0 3.0 3.0 3.0 3.1 3.1 3.0 3.0 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.0 3.1 3.1 3.1 3.0 3.0 3.5 3.5 5.2 4.3 3.5 3.5 5.0 4.7 4.3 4.3 5.6 4.3 4.0 4.1 6.3 4.7 4.3 4.4 6.4 4.6 4.2 4.3 6.2 4.0 3.2 3.3 5.8 3.7 3.8 7.2 5.6 3.7 3.7 6.8 5.5 4.4 5.0 6.3 5.0 4.1 4.8 6.9 5.5 4.5 5.3 7.1 5.4 4.4 5.4 7.5 5.0 3.5 4.1 7.1 4.2 5.2 7.9 6.9 4.3 5.1 7.4 6.7 4.7 5.7 6.6 6.0 4.3 6.3 7.5 6.6 4.7 6.4 7.9 6.6 . 4.6 6.6 8.2 6.2 3.9 6.6 7.8 1lIMJl, 4-C-172 - 4-C-173 Table 4-C-55.Cont.- ~. -------------------------------------~-------------------------------~------ INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ------------------------------------------------------------------------------ 820903 -820904 2125 -0327 2.9 2.9 3.0 3.8 4.1 4.5 ..... 820904 -820904 0328 -0931 2.9 2.9 2.9 3.8 3.9 4.2 820904 -820904 0932 -1535 2.9 2.9 3.0 4.2 5.2 6.0 820904 -820904 1536 -2138 2.9 3.0 3.0 4.4 5.3 6.3 820904 -820905 2139 -0342 2.9 3.0 3.0 3.6 3.8 4.4 820905 ,..820905 0343 -0946 2.9 3.6 3.8 4.3 ~2.9 2.9 820905 -820905 0947 -1549 2.9 2.9 3.0 4.3 5.1 6.0 820905 -820905 1550 -2153 2.9 3.0 3.0 4.4 sa 6.0 - 820905 -820906 2154 -0357 3.0 3.0 3.0 3.9 4.1 4.4 820906 -820906 0358 -1001 2.9 3.0 3.0 3.8 4.0 4.3 -820906 -820906 1002 -1604 2.9 3.0 3.0 4.4 5.0 5.3 820906 -820906 1605 -2208 2.9 3.0 3.1 4.4 4.9 5.3 820906 -820907 2209 -0412 3.0 3.0 3.1 4.1 4.2 4.4 ~.~ 820907 -820907 0413 -1015 2.9 3.0 3.1 4.0 4.4 5.4 820907 -820907 1016 -1619 3.0 3.0 3.1 5.5 6.5 7.4 ..... 820907 -820907 1620 -2223 3.1 3.2 3.2 5.0 5.8 6.9 820907 -820908 2224 -0426'3.1 3.2 3.2 4.3 4.6 5.0 ~ 820908 -820908 0427 -1030 3.1 3.1 3.2 4.2 4.3 4.7 820908 -820908 1031 -1634.3.1 3.1 3.2 4.7 5.5 5.8 820908 -820908 3.1 3.1 3.2 4.7 5.2 5.7 ~;1635 -2238 820908 -820909 2239 -0441 3.1 3.1 3.2 4.2 4.4 4.7 ~ 820909 -820909 0442 -1045 3.0 3.1 3.1 4.1 4.2 4.6 820909 -820909 1046 -1649 3.0 3.1 3.1 4.6 5.5 6.4 820909 -820909 1650 -2252 3.1 3.1 3.2 4.3 4.8 5.6 820909 -820910 2253 -0456 3.1 3.1 3.1 3.8 4.0 4.3 820910 -820910 3.0 3.1 3.1 3.8 4.1 4.6 ~0457 -1100 820910 -820910 1101 -1703 3.0 3.1 3.1 4.6 5.1 5.5 820910 -820910 1704 -2307 3.0 3.1 3.1 4.0 4.5 5.2 ~ -----------------------------------------------~-------------------------- 4-C-174 - Table 4-G-55.Cant. --------~--~--~-~------------------------------~----=--~-----------~--------INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------- 820910 ...820911 2308 -0511 3.0 3.1 3.1 3.7 3.8 4.0 820911 -820911 0512 -1115 3.0 3.0 3.1 3.6 3.9 4.2-,820911 -820911 1116 -1718 3.0 3.0 3.0 4.2 4.5 4.7 820911 -820911 1719 -2322 3.0 3.0 3.1 3.8 4.1 4.5 820911 -820912 2323 -0526 3.0 3.0 3.1 3.5 3.6 3.8 820912 -820912 0527 -1129 3.0 3.0 3.0 3.4 3.5 3.5 820912 -820912 1130 -1733 2.9 3.0 3.0 3.5 4.6 5.3 820912 -820912 1734 -2337 2.9 3.0 3.1 3.9 4.2 4.6 820912 -820913 2338 -0540 3.0 3.1 3.1 3.8 3.9 4.0 820913 -820913 0541 -1144 3.0 3.0 3.0 3.8 3.9 4.1 820913 -820913 1145 -1748 2.9 3.0 3.0 4.1 4.5 5.2 ~~"820913 -820913 1749 -2352 3.0 3.0 3.1 4.0 4.1 4.3 820913 -820914 2353 -0555 3.1 3.1 3.1 3.8 3.9 4.1 820914 -820914 0556 -1159 3 .1 3.1 3.1 3 .7 4.1 4.9 820914 -820914 1200 -1803 3 .1 3.1 3.2 4.6 4.8 4.9 820914 -820915 1804 -0006 3.2 3.2 3.3 4.3 4.4 4.6 820915 -820915 0007 -0610 3.3 3.3 3.3 4.1 4.3 4.4 r-820915 -820915 0611 -1214 3.3 3.3 3.4 4.1 4.4 4.9 820915 -820915 1215 -1817 3.3 3.4 3.5 4.8 5.3 5.5 820915 -820916 1818 -0021 3.5 3.5 3.5 4.5 4.6 4.9 820916 -820916 0022 -0625 3.5 3.5 3.5 4.3 4.4 4.6 820916 -820916 0626 -1229 3.5 3.5 3.5 4.5 4.6 4.9-820916 -820916 1230 -1832 3.5 3.8 4.2 4.7 5.3 5.6 820916 -820917 1833 -0036 4.0 4.1 4.2 4.6 4.7 5.1 820917 .;.820917 0037 -0640 3.8 3.9 4.0 4.2 4.4 4.6 820917 -820917 0641 -1243 3.7 3.8 3.8 4.2 4.4 4.7 820917 -820917 1244 -1847 3.8 3.9 3.9 4.6 4.7 4.8 820917 -820918 1848 -0051 3.7 3.8 3.9 4.2 4.3 4.6,t~., ~--------------------------------------------------------------------~------- 4-C-175 Table 4-C-55.Cont. -----------~-----------------~~-----~-----~-----~-------~-------~---------IMTRAGRAVEL SURFACE WATER DATE TIME ----.....---------------------~----------PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX -, --------------------------------------~-~-~-----------------~------~------- 820918 -820918 0052 -0654 3.6 3.7 3.7 3.9 4.0 4.2 820918 -820918 0655 -1258 3.5 :L6 3.7 3.9 4.3 4.7 820918 -820918 1259 -1902 3.6 3.7 3.8 4.3 4.6 4.8 820918 -820919 1903 -0106 3.6 3.6 3.7 4.0 4.1 4.4 820919 -820919 0107 -0709 3.5 3.5 3.6 3.9 3.9 4.0 -. 820919 -820919 0710 ...1313 3.5 3.5 3.S 3.9 4.1 4.3 820919 -820919 1314 -1917 3.5 3.5 3.f1 4.1 4.3 4.4 820919 -820920 1918 -0120 3.5 3.5 3.5 3.9 4.0 4.2 8.20920 -820920 0121 -0724 3.4 3.5 3.5 3.8 3.9 4.0 820920 -820920 0725 ...1328 3.4 3.4 3.5 3.8 4.1 4.6 820920 -820920 1329 -1931 3.5 3,.5 3.6 ,4.2 4.5 4.6 820920 -820921 1932 ...0135 3.5 3.5 3.5 3.9 4.0 4.2 .--' 820921 -820921 0136 ...0739 3.4 3.5 3.5 3.7 3.8 3.9 820921 -820921 0740 -13'43 3.4 3.5 3.6 3.8 4.2 4.6 820921 -820921 1344 -1946 3.5 3.6 3.6 -4.1 4.3 4.5 ~j 820921 -820922 1947 -0150 3.5 3.5 3.5 3.9 4.0 4.1 ..... 820922 -820922 0151 -0754 3.4 3.5 3.5 3.7 3.8 3.9 820922 -820922 0755 -1357 3.4 3.4 3.5 3.7 4.2 4.6 820922 -820922 1358 -2001 3-.5 3.6 3.7 4.1 4.6 5.1 "'"' 820922 -820923 2002 -0205 3.4 3.5 3.6 3.5 3.7 4.1 820923 -820923 0206 -0808 3.3 3.3 3.4 3 .4 3.5 3.5 820923 -820923 0809-1412 3.2 3.2 3.3 3.4 3 .6 4.4 820923 -820'923 1413 -2016 3 .3 3.4 3.5 3.7 4.3 4.7 ~ 820923 -820924 2017 -0220 3.1 3.3 3.4 3.2 3.4 3.7 820924 -820924 0221 -0823 3.1 3-.1 3.1 3.1 3.2 3.2 820924 -820924 0824-1427 3.1 3.2 3.3 3.3 3.8 4.5 820924 -820924 1428 -2031 3.3 3.4 3.4 3.6 4.1 4.5 820924 -820925 2032 -0234 3.2 3.2 3 ..3 3.3 3.4 3.6 ------------~-------~-------~._~------~--~---_._---'-_.~~--~-~-~------------- 4-"'C-176 Table 4-C-55.Cont. 4-C-177 Table 4-C-55.Cant. --------~----~---------------~--~_.~--------~-------~----------------~~~-- DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX --------~------~-------~--~-----~--~---------------~~~---~~-------~~-- 821002 -821002 0419 -1022 ..............---....--3.1 3.2 3.5 821002 -821002 1023 -1625 ~-_........-----3.5 4.1 4.4 821002 -821002 1626 -2229 -------------_...3.3 3.1 4.3 821002 -821003 2230 -0433 _......---'...-_...--.-2.9 3.1 3.3 821003 -821003 0434 ...103'6 ~..........~-------2.9 3.1 3.5 821003 -82l(l03 10-37 -1640 .............................--...-....3.5 4.0 4.4 821003 -821003 16'41 ..2244 ...,.........-.~-----3.2 3.6 4.1 821003 -821004 2245 -0448 ...............--....................2.7 2.9 3.1 821004 -821004 0449 -1051 ..........---'....-------2.6 2.7 3.0 821004 -821004 1052 -1655 -.......................-2.9 3.5 4.0 821004 -821004 1656 -2259 .............-~..2.6 3.1 3.7 821004 -821005 2300 ..05(12 -------'~...2.6 2.7 2.9 821005 -821005 0503 -1106 -~-................-_....~.5 2.7 3.4 821005 -821005 1107 -171;0 ..~-_.......----fJ..7 3.1 3.5 821005 -821005 1711 ...2313 ............................--...."-2.5 2.'8 3.5 821005 -821006 2314 -0517 ~--..........------.2.4 2.5 2.6 821006 -821006 0518 -11'21 ...-----...-~2.4 2.6 2.9 821006 -821006 1122 -1725 -~-~- ___'IiiiiiIIlii_-----2.9 3.4 3.6 821006 -821006 1726 -2328 -.....-.-.--_...................-2-06 2.,8 3.2 821006 -821007 2329 -0532 .............i-o_'.''''-'2.5 2.6 2.6 821007 -821007 0533 ",.113~6 ......-...-........'........--...---2.S 2.6 2.8 821007 -82 Hl07 1137 ...1739 ------_....................~-2.7 3.0 3.2 821007 -821007 1740 -2343 '......---"-2.5 2~7 2.8 821007 -821008 2344 -0547 ......._-........,..-~2.2 2.4 2.6 821008 -821008 0548 -1150 -...._-------2.0 2.5 3.3 821008 -8HOO8 1151 -1754 ~......._------------..3.0 3.4 3.6 821008 -821008 1755 ...2358 ------2.5 2.7 3.0 821008 -821009 2359 -0602 ................----2.4 2.5 2.6 --------------------~---~----~~--~~.~._------.~-..-...~....---~~--~-~-----~- 4-C-178 - .... - Table 4-C-55.Cont. --------~-----------------------~-------------------------------------------INTRAGRAVEL SURFACE WATER ~DATE TIME -------------------------------------~PERIOD PERtOD MIN MEAN MAX MIN MEAN MAX ----.---------~-----------,..------------------------------------- 821009 -821009 0603 -1205 2.4 2.7 3.2 .....821009 -821009 1206 -1809 2.9 3.2 3.4 821009 -821010 1810 -0013 2.6 2.7 2.9 821010 -821010 0014 -0616 2.5 2.6 2.7 821010 -821010 0617 -1220 2.4 2.7 3.0 821010 -821010 1221 -1824 2.5 2.8 3.1 821010 -821011 1825 -0027 2.5 2.6 2.7 821011 -821011 0028 -0631 2.6 2.7 2.7 821011 -821011 0632-1235 2.6 2.9 3.3 821011 -821011 1236 -1839 2.6 3.0 3.4 !"""-,,.821011 -821012 1840 -0042 2.4 2.5 2.6 821012 -821012 .0043 -0646 2.2 2.3 2.4 ~821012 -821012 0647 -1250 2.2 2~5 2.9 821012 -821012 1251 -1853 2.6 2.8 2.9 821012 -821013 1854 -0057 1.7 2.3 2.6 ~iI'i\!lI 821013 -821013 0058 -0701 1.8 2.0 2.2 821013 -821013 0702 -1304 2.2 2.6 3.1 ~821013 -821013 1305 -1908 2.5 2~9 3.2 821013 -821014 1909 -0112 2.2 2.3 2.6 ~ 821014 -821014 0113 -0716 2.2 2.3 2.3 821014 -821014 0717 -1319 2.3 2.9 3.8 821014 -821014 1320 -1923 2.8 3.5 4.0 821014 -821015 1924 -0127 2.7 2.8 2.9 821015 -821015 0128 -0730 2.7 2.8 2.8 821015 -821015 0731 -1334 2.7 3.2 3.5 821015 -821015 1335 -1938 2.6 3.0 3.3 821015 -821016 1939 -0141 2.5 2.7 2.9 -----------------~---------------------------------------------------------- -4-C-179 -------------------------~----~--~~-~-------------------------~-----------~ 4.-C-180 Table 4-C-55.Cont. --------~------~----------------------------------------------------------- DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX-----.._-,~~------------~--~-------------------------------------------- 821023 -821023 0326 -0929 2.3 2.3 2.4 821023 -821023 0930 -1532 2.2 2.3 2.4 821023-821023 1533 -2136 2.1 2.1 2.3 821023 -821024 2137 -0340 2.2 2.2 2.3 821024 -821024 0341 -0944 2.2 2.2 2.3 821024 -821024 0945 -1547 2.3 2.5 2.6 821024 -821024 1548 -2151 2.4 2.5 2.6 ,...,. , 821024 -821025 2152 -0355 2.4 2.5 2.6 821025 -821025 0356 -0958 2.2 2.3 2.5 ----------------~---------------------------------------------------------- - 4-C-181 Table4-C-56.Datapod intragravel and surface water temperature (C)continuous record,at Slough 21-Mouth,RM 141.8,Geocode S31N02W02AAB. Note,that time periods are 6 hours and 3 minutes and 42~, seconds in duration;accordingly,daily minimum,maximum and mean values can not be directly calculated from this data. ----------------------------------------------------------------------------- DATE PERIOD TIME PERIOD INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX ------~--------------------------------------------------------------------- 820917 -820917 820917 -820917 820917 -820917 820917 -820918 820918 -820918 820918 -820918 820918 -820918 820918 -820919 820919 -8209~9 820919 -820919 820919 -820919 820919 -820920 820920 -820920 820920 -810920 820920 -820920 820920 -820921 820921 -820921 820921 -820921 820921 -820921 820921 -820922 820922 -820922 820922 -820922 820922 -820922 820922 -820923 820923 -820923 820923 -820923 820923 -820923 0001 ...0604 0605 -1207 1208 -1811 1812 ...0015 0016 -0619 0620 ...1222 1223 -1826 1827 -0030 0031 -0633 0634 -1237 1238 ...1841 1842 -0044 0045 -0648 0649 -1252 1253 -1856 1857 -0059 0100 -0703 0704 -1307 1308 -1910 1911 -0114 0115 -0718 0719 -1321 1322 -1925 1926 -0129 0130 -0733 0734 ...1336 1337 -1940 3.7 6.7 6.8 6.1 5.5 5.2 5.2 4.5 4.4 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 6.2 6.9 6.9 6.4 5.8 5.5 5.5 4.8 4.5 4.4 3.7 3.7 3.6 3.7 3.7 3.7 3.7 3.6 3.6 3.7 3.6 3.7 3.6 3.6 3.6 3.6 3.7 7.4 7.1 7.0 6.8 6.1 5.7 5.8 5.2 4.6 5.4 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 6.8 6.6 6.6 6.0 5.3 5.1 4.7 4.3 4.5 4.5 4.7 4.7 4.5 4.5 4.6 4.5 4.4 4.6 4.9 4.2 3.5 3.7 3.6 3.2 2.6 2.6 3.2 7.2 6.7 6.8 6.3 5.7 5.4 5.3 4.5 5.1 5.5 5.0 4.9 4.8 5.0 5.1 4.6 4.6 5.3 5.2 4.6 3.9 4.4 4.6 3.3 2.9 3.1 4.3 7.5 6.9 6.9 6.6 6.1 5.7 5.7 4.7 5.9 7.1 5.3 5.1 5.3 5.6 5.6 4.8 4.9 5.8 5 .6 5.0 4.3 4.9 5.3 3.5 3.2 4.0 5.2 """ - -----------------------------------------_.~--------------------------------- 4-C-182 Table4-C-56.cont. --~~--_-._~----------~----------------------------------------~---~~~~~~--INTRAGRAVEL SURFACE WATER DATE TIME ------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX--....--------------------------------------------------~------ ""'"820923 -820924 1941 -0144 3.6 3.6 3.7 2.5 2 .7 3.2 820924 -820924 0145-0747 3.6 3.6 3.7 2.3 2.4 2.6 820924 -820924 0748 -1351 3.6 3.6 3.7 2.4 3.4 4.7 820924 -820924 1352 -1955 3.6 3.6 3.7 3.5 4.2 4.9 820924 -820925 1956 -0158 3.6 3.6 3.7 2.9 3.1 3.5 820925 -820925 0159 -0802 3.6 3.7 3.7 2.6 2.8 3.1 820925 -820925 0803 -1406 3.6 3.6 3.7 2.6 3.7 4.7 ~820925 -820925 1407 -2010 3.6 3.6 3."3.7 4.1 4.5 820925 -820926 2011 -0213 3.6 3.7 3.7 3.2 3.5 3.6 820926 -820926 0214 -0817 3.6 3.7 3.7 3.2 3.3 3.4 820926 -820926 0818 -1421 3.6 3.6 3.7 3.4 3.9 4.3 820926 -820926 1422 -2024 3.6 3.7 3.7 3.5 3.8 4.2 ~_l,,"-- 820926 -820927 2025 -0228 3.6 3.6 3.7 3.5 3.5 3.5 820927 -820927 0229 -0832 3.6 3.6 3.6 3.4 3.4 3.5 r-820927 -820927 0833 -1435 3.6 3.7 3.7 3.5 4.2 5.0 820927 -820927 1436 -2039 3.6 3.6 3.7 3.0 3.9 4.6 820927 -820928 2040 -0243 3.6 3.6 3.7 2.6 2.7 2.9 820928 -820928 0244 -0847 3.6 3.7 3.7 2.4 2.5 2.8 820928 -820928 0848 -1450 3.6 3.7 3.7 2.9 3.7 4.2 820928 -820928 1451 -2054 3.6 3.6 3.7 3.4 3.6 3.9 820928 -820929 2055 -0258 3.6 3.7 3.7 3.3 3.4 3.4 820929 -820929 0259 -0901 3.7 3.7 3.7 3.3 3.3 3.5 820929 -820929 0902 ,-1505 3.6 3.7 3.7 3.5 4.2 4.8 820929 -820929 1506 -2109 3.6 3.7 3.7 3.5 3.9 4.6 820929 -820930 2110 -0312 3.6 3.7 3.7 3.4 3.5 3.6 820930 -820930 0313 -0916 3.6 3.7 3.7 3.4 3.4 3.6 820930 -820930 0917 -1520 3.6 3.7 3.7 3.7 4.4 5.1 820930 -820930 1521 -2124 3.6 3.7 3.7 3.5 3.9 4.7 ------------~-------------------------------------------------------------- """ 4-C-183.- 4-C-184 Tab Ie 4-C-56.cont. -------------------_..------------------------------------------------------- INTRAGRAVEL SURFACE WATER-DATE TIME ------------------------------------~-PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX --_._----------------.---------------------------------------------------- .- 821007 -821008 2308 -0511 3.6 3.7 3.7 2.2 2.5 2.7 821008 -821008 0512 -1115 3.6 3.6 3.6 2.5 2.7 3.4.....821008 -821008 1116 -1718 3.6 3.6 3.6 3.0 3.6 3.9 821008 -821008 1719 -2322 3.6 3.6 3.7 1.5 2.4 3.0 821008 -821009 2323 -0526 3.6 3.6 3.6 1.5 2.0 2.5 821009 -821009 0527 -1129 3.6 3.6 3.7 2.5 2.8 3.4 821009 -821009 1130 -1733 3.6 3.6 3.6 3.1 3.5 3.7 . 8~.1009 -821009 1734 -2337 3.6 3.6 3.7 2.7 2.8 3.1 821009 -821010 2338 ..0540 3.6 3.6 3.7 2.7 2.7 2.8 ..... 0541 -1144821010-821010 3.6 3.7 3.7 2.6 2.9 3.5 821010 -821010 1145 -1748 3.7 3.7 3.7 2.6 3.1 3.4 821010 ...821010 1749 -2352 3.7 3.7 3.7 2.5 2.6 2.7 ,~ 821010 -821011 2353 -0555 3.6 3.7 3.7 2.3 2.4 2.5 821011 -821011 0556 -1159 3.6 3.7 3.7 2.3 2.5 2.9 821011 -821011 1200 -1803 3.6 3.7 3.7 1.2 .2.8 3.3 821011 -821012 1804 -0006 3.6 3.7 3.7 1.6 2.4 2.7 821012 -821012 0007 -0610 3.6 3.7 3.7 1.8 2.2 2.6 821012 -821012 0611 -1214 3.6 3.7 3.7 2.2 2.6 3.3 821012 -821012 1215 ..1817 3.6 3.7 3.7 3.0 3.2 3.3 821012 -821013 1818 -0021 3.6 3.7 3.7 1.7 2.6 3.0 --821013 -821013 0022 -0625 3.6 3.7 3.7 2.4 2.5 2.6 821013 -821013 0626 -1229 3.6 3.7 3.7 2.6 2.7 2.8 821013-821013 1230 -1832 3.7 3.7 3.7 2.4 2.8 3.1 821013 -821014 1833 -0036 3.7 3.7 3.7 2.3 2.5 2.6 821014 -821014 0037 -0640 3.6 3.6 3.7 1.9 2.3 2.4 821014 -821014 0641 -1243 3.6 3.7 3.7 1.8 2.5 3.3 821014 -821014 1244 -1847 3.7 3.7 3.7 2.1 3.1 3.7 821014 -821015 1848 -0051 3.7 3.7 3.7 1.5 1.7 2.1 ----------------------------------------------------------------------- ;~ 4-C-185 -."-Table 4-C-56.cont. .... ------------------------------------------------------~------------~---~~~-INTRAGRAVEL SURFACE WATER DATE TIME ---------~--------------------------~-PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ------------------------------------------- 821022 -821022 0235 -0838 3.6 3.6 3.7 .6 .8 1.0 821022 -821022 0839 -1442 3.6 3.6 3.7 .9 1.3 1.5 821022 -821022 1443 -2045 3.6 3.7 3.7 .9 1.2 1.4 821022 -821023 2046 -0249 3.6 3.6 3.6 .9 1.0 1.1 821023 -821023 0250 -0853 3.6 3.6 3.6 .9 .9 1.0 821023 -821023 0854 -1457 3.6 3.6 3.7 .8 1.0 1.2 821023 -821023 1458 -2100 3.6 3.6 3.6 .6 .9 1.1 821023 -821024 2101 -0304 3.6 3.6 3.7 .3 .5 .8 821024 -821024 0305 -0908 3.6 3.6 3.6 .8 1.1 1.2 ~821024 -821024 0909 -1511 3.6 3.6 3.7 1.1 1.4 1.9 821024 -821024 1512 -2115 3.6 3.6 3.7 .8 1.4 1.9 ~,.....-...821024 -821025 2116 -0319 3.6 3.7 3.7 .7 .9 1.0 821025 -821025 0320 -0922 3.7 3.7 3.7 .8 1.1 1.3 -------------------------------------------------------_. 4-C-187 Tab1e4-C-57.Datapod intragravel and surface water temperature (C)continuous record.at Slough 21-Upper,RM 142.0,Geocode S32N02W36CCC. Note,that time periods are 6 hours and 3 minutes and 42 seconds in duration;accordingly,daily minimum,maximum and mean values can not be directly calculated from this data. ----------------------------------------~------------------------~----------- '"'"1\ DATE PERIOD TIME PERIO.D INTRAGRAVEL MIN MEAN MAX SURFACE WATER MIN MEAN MAX - 820821 -820821 820821 -820821 820821 -820821 0001 -0604 0605 -1207 1208 -1811 3.7 3.7 3.7 3.7 3.7 3.7 3.8 3.8 3.8 4.0 4.1 6.5 4.2 4.6 7.3 4.6 6.5 7.9 '""" 820821 -820822 1812 -0015 3.7 3.7 3.8 4.5 5.1 6.5 820822 -820823 1827 -0030 820822 -820822 820822 -820822 820822 -820822 820823 -820823 820823 -820823 820823 -820823 820823 -820824 820824 -820824 820824 -820824 820824 -820824 820824 -820825 820825 -820825 820825 -820825 820825 -820825 820825 -820826 0016 -0619 0620 -1222 1223 -1826 0031 -0633 0634 -1237 1238 -1841 1842 -0044 0045 -0648 0649 -1252 1253 -1856 1857 -0059 0100 -0703 0704 -1307 1308 -1910 1911 -0114 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.8 4.1 3.9 3.9 3.9 4.2 4.0 3.7 3.7 3.7 3.7 3.8 3.7 3.7 3.8 3.8 4.0 4.3 4.0 4.0 4.1 4.4 4.1 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.9 4.3 4.4 4.0 4.3 4.6 4.2 3.9 3.9 6.2 5.0 4.8 4.8 5.8 4.7 4.6 4.7 .6.3 5.0 4.8 4.9 6.0 5.0 4.1 4.5 7.1 5.4 4.9 5.3 6.4 5.0 4.7 5.4 7.1 5.4 5.0 5.9 7.3 5.4 4.5 6.7 7.6 6.2 5.0 5.9 6.9 5.7 4.8 6.8 7.6 6.4 5.1 6.9 8.1 6.0 - 820826 -820826 .0115 -0718 820826 -820826 0719 -1321 820826 -820826 1322 -1925 4.0 3.9 4.2 4.0 4.2 4.4 4.1 4.5 4.6 4.9 5.0 6.0 5.0 6.1 7.5 5.1 7 .6 8.3 820826 -820827 820827 -820827 820827 -820827 820827 -820827 1926 -0129 0130 -0733 0734 -1336, 1337 -1940 3.9 3.8 3.8 4.1 4.0 3.9 4.0 4.3 4.2 4.0 4.4 4.6 4.4 3.9 4.0 5.5 5.0 4.1 5.2 7.3 5.9 4.4 7.5 8.3 4-C-188 Table4-C-57.Cont. -------------------------------------------------------------------~---------INTRAGRAVEL SURFACE WATER-DATE TIME ----------------------------------~---PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX ----------------------------------------------------------------------------- """820827 -820828 1941 -0144 3.8 4.0 4.1 4.3 4.7 5.5 820828 -820828 0145 -0747 3.8 3.9 3.9 4.2 4.4 4.6 820828 -820828 0748 -1351 3.8 4.0 4.2 4.6 5.2 6.3 820828 -820828 1352 -1955 4.1 4.2 4.3 5.6 6.4 7.1 ~820828 -820829 1956 -0158 3.9 4.0 4.1 4.7 4.9 5.5 820829 -820829 0159 -0802 3.8 3.9 4.0 4.6 4.6 4.8 820829 -820829 0803 -1406 3.9 4.0 4.2 4.8 5.5 6.2 820829 -820829 1407 -2010 4.0 4.1 4.2 5.2 5.9 6.2 820829 -820830 2011 -0213 3.9 4.0 4.0 4.7 4.9 5.1 820830 -820830 0214 -0817 3.9 4.0 4.0 4.7 4.8 4.8 820830 -820830 0818 -1421 3.9 4.0 4.1 4.8 5.2 5.4 ~,~~,820830 -820830 1422 -2024 3.9 4.0 4.1 4.9 5.4 5.5 820830 -820831 2025 -0228 3.8 3.9 4.0 4.6 4.7 4.9-.820831 -820831 0229 -0832 3.9 3.9 4.0 4.5 4.6 4.8 820831 -820831 0833 -1435 3.9 4.0 4.2 4.8 5.5 6.5 .820831 -820831 1436 -2039 3.9 4.1 4.3 4.8 6.0 6.7 820831 -820901 2040 -0243 3.9 3.9 4.0 4.6 4.7 4.9 820901 -820901 0244 -0847 3.8 3.9 4.0 4.6 4.7 5.2 820901 -820901 0848,-1450 4.0 4.2 4.3 5.2 6.2 6.9 820901 -820901 1451 -2054 3.9 4.1 4.3 4.7 5.9 6.9-820901 -820902 2055 -0258 3.9 3.9 4.0 4.5 4.6 4.7 820902 -820902 0259 -0901 3.8 3.9 3.9 4.4 4.5 4.7 820902 -820902 0902 -1505 3.9 4.1 4.3 4.8 6.0 7.1 820902 -820902 1506 -2109 4.0 4.1 4.3 5.1 6.1 7.0 820902 -820903 2110 -0312 3.9 4.0 4.0 4.7 4.8 5.1 820903 -820903 0313 -0916 3.9 3.9 3.9 4.6 4.7 4.8 820903 -820903 0917 -1520 3.9 4.0 4.1 4.8 5.4 6.4-820903 -820903 1521 -2124 3.8 4.0 4.1 4.6 5.5 6.4 ,-,, .....-~--------------------------------------------------------------------------- 4-C-189 Table 4-C-57.Cont. ~ A"l" --------------------------------~----~--------~--------~---~~~----~----~--INTRAGRAVEL SURFACE WATE:R DATE TIME -------------------------~------------PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX .-,. . . .".~, ------------------------------------------~---------------------------------- 820903 -820904 2125 -0327 3.8 3.9 3.9 4.3 4.4 4.6 -820904 -820904 0328 -0931 3.8 3.9 3.9 4.2 4.4 4.7 820904 -820904 0932 -1535 3.8 4.0 4.1 4.7 5.6 6.7 820904 -820904 1536 -2138 3.8 4.0 4.1 4.5 5.5 6.7 820904-820905 2139 -0342 3.8 3.9 3.9 4.0 4.2 4.5 820905 820905 0343 0946 3.8 3.9 3.9 4.2 4.4 4.9 -- - 820905 -820905 0947 -1549 3.8 3.9 4.1 4.9 5.5 6.3 820905 -820905 1550 -2153 3.9 4.0 4.1 4.8 5.4 6.3 820905 -820906 2154 -0357 3.9 3.9 3.9 4.6 4.7 4.9 820906 -820906 0358 -1001 3.8 3.9 3.9 4.5 4.6 4.8 ~820906 -820906 1002 -1604 3.9 3.9 4.0 4.8 .5.4 5.8 820906 -820906 1605 -2208 3.8 3.9 4.0 4.4 5.0 5.6 820906 -820907 2209 -0412 3.8 3.8 3.9 4.4 4.4 4.5 ~,- 820907 -820907 0413 -1015 3.8 3.8 4.0 4.4 4.6 5.5 820907 -820907 1016 -1619 3.9 4.0 4.1 5.6 6.4 7.2 ~- 820907 -820907 1620 -2223 3.9 3.9 4.1 4.7 5.3 6.7 820907 -820908 2224 -0426 3.8 3.9 3.9 4.5 4.6 4.7 820908 -820908 0427 -1030 3.8 3.9 3.9 4.4 4.6 5.0 820908 -820908 1031 -1634 3.9 3.9 4.0 5.0 5.6 5.9 820908 -820908 1635 -2238 3.8 3.9 4.0 4.6 4.9 5.5 ~ 820908 -820909 2239 -0441 3.8 3.9 3.9 4.5 4.5 4.6 820909 -820909 0442 -1045 3.8 3.9 3.9 4.5 4.6 4.9 820909 -820909 1046 -1649 3.9 4.0 4.1 5.0 5.8 6.5 820909 -820909 1650 -2252 3.8 3.9 4.0 4.4 4.9 5.8 820909 -820910 2253 -0456 3.8 3.9 3.9 4.3 4.4 4.5 820910 -820910 0457 -1100 3.8 3.8 3.9 4.2 4.5 5.3 820910 -820910 1101 -1703 3.9 3.9 4.0 5.3 5.8 6.2 820910 -820910 1704 -2307 3.8 3.9 3.9 4.3 4.7 5.6 - -----------------------------~~~-----------------~~---~~-------------- _. ('>-'"','\ ~ 4-C-190 ..... Table 4~C-57.Cont. "'-.- ----------------------------------------------------------------------------- INTRAGRA VEL SURFACE·WATER DATE TIME -------------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX-----,._-------------------------------------------------------------------- 820910 -820911 2308 -0511 3.8 3.9 3.9 4.1 4.2 4.3 820911 -820911 0512 -1115 3.8 3.8 3.9 4.1 4.3 4.6 820911 -820911 1116 -1718 3.8 3.8 3.9 4.6 4.8 5.0 820911 -820911 1719 -2322 3.8 3.8 3.9 4.1 4.4 4.8 820911 -820912 2323 -0526 3.8 3.8 3.9 3.7 4.0 4.1 820912 -820912 0527 -1129 3.7 3.8 3.9 3.5 3.5 3.8-820912 -820912 1130 -1733 3.7 3.8 3.9 3.8 5.2 6.0 820912 -820912 1734 -2337 3.8 3.8 3.9 4.2 4.4 5.0 820912 -820913 2338 -0540 3.8 3.8 3.8 4.1 4.2 4.2 820913 -820913 0541 -1144 3.8 3.8 3.9 4.1 4.2.4.5 820913 -820913 1145 -1748 3.8 3.8 3.9 4.6 5.0 5.6 ~,~~820913 -820913 1749 -2352 3.8 3.9 3.9 4.5 4.6 4.8 820913 -820914 2353 -0555 3.8 3.9 3.9 4.4 4.5 4.6 820914 -820914 0556 -1159 3.8 3.8 3.9 4.4'4.6 5.5 820914 -820914 1200 -1803 3.8 3.8 3.9 4.9 5.2 5.5 ~820914 -820915 1804 -0006 3.8 3.8 3.9 4.7 4.8 5.0 820915 -820915 0007 -0610 3.9 3.9 3.9 4.7 4.7 4.8 F'820915 -820915 0611 -1214 3.8 5.0 5.8 4.8 6.4 7.3 820915 -820915 1215 -1817 5.6 5.8 6.0 7.3 7.5 7.7 820915 -820916 1818 -0021 5.8 6.0 6.2 7.6 7.9 8.1 820916 -820916 0022 -0625 5.9 6.1 6.3 7.9 8.0 8.2 820916 -820916 0626 -1229 5.6 6.2 6.9 7.7 7.8 8.0 820916 -820916 1230 -1832 6.8 7.3 7.5 7.7 7.8 7.9 820916 -820917 1833 -0036 7.2 7.4 7.5 7.7 7.7 7.8 820917 -820917 0037 -0640 6.0 6.9 7.4 7.1 7.4 7.7 820917 -820917 0641 -1243 5.8 6.6 6.9 6.9 7.0 7.2 820917 -820917 1244 -1847 5.8 6.3 6.5 6.9 7.1 7.2 820917 -820918 1848 -0051 5.3 5.6 5.9 6.5 6.7 6.9 -----------~----------------------------------------------------------------- 4-C-191 -4-C-193 .... 4-C-195 Table 4-C-57.Cont.I'!'" ~.. -------------------------------.-------~---------------------------~----------~l INTRAGRAVEL SURFACE WATER DATE TIME --------------------~~-------~-------PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX --------------------------~---------~~-----------------~------------------- 821016 -821016 0142 -0745 3.5 3.5 3.6 2.5 2.6 2.7 821016 821016 0746 1349 3.5 3.6 3.7 2.6 2.7 2.9 ~-- 821016 -821016 1350 -1953 3.5 3.6 3.7 2.6 2.7 2.8 821016 -821017 1954 -0156 3.5 3.5 3.6 2.5 2.7 2.8 ~ 821017 -821017 0157 -0800 3.5 3.6 3.7 2.7 2.8 2.9 821017 -821017 0801 -1404 3.6 3.8 3.9 2.8 3.2 3.6 ~ 821017 -821017 1405 -2007 3.5 3.7 3.8 2.5 3.0 3.4 821017 -821018 2008 -0211 3.5 3.5 3.5 2.4 2.4 2.6 """! 821018 -821018 0212 -0815 3.5 3.5 3.6 2.3 2.4 2.5 821018 -821018 0816 -1418 3.5 3.6 3 ..7 2.4 2.8 3.2 821018 -821018 1419 -2022 3.5 3 .6 3.7 2.6 2.8 3.1 ~ 821018 -821019 2023 -0226 3.5 3.6 3.6 2.6 2.7 2.8 821019 821019 0227 -0830 3.4 3.6 3.7 2.2 2.6 2.8 .ABW'-~- 821019 -821019 0831 -1433 3.5 3.6 3.7 2.3 2.7 3.1 821019 -821019 1434 -2037 3.5 3.6 3.8 2.6 2.9 3.1 821019 -821020 2038 -0241 3.5 3.5 3.6 2.4 2.6 2.8 821020 -821020 0242 -0844 3.4 3.5 3.5 2.4 2.6 2.6 ~l 821020 -821020 0845 -1448 3.5 3.5 3.6 2.5 2.7 2.9 821020 -821020 1449 -2052 3.4 3.5 3.6 2.2 2.6 2.9 821020 -821021 2053 -0255 3.3 3.4 3.5 2.1 2.2 2.4 821021 -821021 '0256 -0859 3.3 3.4 3.5 2.1 2.2 2.3 821021 -821021 0900 -1503 3.4 3.5 3.5 2.2 2.4 2.5 ~ 821021 -821021 1504 -2107 3.4 3.5 3.5 2.0 2.2 2.4 821021 -821022 2108 -0310 3.4 3.5 3.5 2.0 2.1 2.2 ~ 821022 -821022 0311 -0914 3.4 3.5 3.5 2.0 2.2 2.3 821022 -821022 0915 -1518 3.5 3.5 3.6 2.2 2.4 2.6 821022 -821022 1519 -2121 3.4 3.5 3.5 2.1 2.3 2.5 821022 -821023 2122 -0325 3.3 3.5 3.5 2.0 2.2 2.4 ""'" --------------------------------_..~-------------~-------~-~------------~- 1f!I"If~ 4-C-196 ~ -Table 4-C-57.Cont. ,,'"""" ---------._-----------------------------------------~-~~~~-------------------INTRAGRAVEL SURFACE WATER DATE TIME -------------------------------- PERIOD PERIOD MIN MEAN MAX MIN MEAN MAX. -------------------------------------------------------- 821023 -821023 0326 -0929 3.3 3.5 3.5 2.0 2.2 2.4 821023 -821023 0930 -1532 3.4 3.5 3.5 2.1 2.3 2.4 821023 -821023 1533 -2136 3.4 3.4 3.5 2.0 2.2 2.3 ~~ 821023 -821024 2137 ~0340 3.3 3.4 3.5 1.8 2.0 2.3 821024 -821024 0341 -0944 3.4 3.5 3.5 2.1 2.3 2.5 821024 -821024 0945 -1547 3.4 3.5 3.6 2.3 '2.5 2.6 821024 -821024 1548 -2151 3.3 3.4 3.5 1.9 2.3 2.6 821024 -821025 2152 -0355 3.3 3.4 3.5 1.9 2.2 2.3 821025 -821025 0356 -0958 3.4 3.4 3.5 2.0 2.2 2.4 ~~ ----------~---------------------------------------------------------------- - 4-C-197 Table4-C-58.Mean intragravel and surface water temperature (C)datapod data summary at Slough SA-Mouth,RM 125.4,Geocode S3llN03W30BCD.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. -AUGUST 1982 - "-"",.",----------------------------------------------------------------------------------- TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 DAYS 25·";'31 INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER -----------------------------------------------------------------------------------~ 0001 -0600 6.8 10.4 0601 -1200 6.8 9.9 1201 -1800 6.8 11.4 1801 -2400 6.8 11.5 DAILY VALUE 6.8 10.8 0001 -0600 6.8 10.3 0601 -1200 6.8 10.0 1201 -1800 6.9 12.2 1801 -2400 6.9 12.5 DAILY VALUE 6.8 11.2 0001 -0600 6.9 10.4 0601 -1200 6.8 9.7 1201 -1800 6.8 11.8 1801 -2400 6.8 12.2 DAILY VALUE 6.8 11.0 0001 -0600 6.8 10.2 0601 -1200 6.7 9.0 1201 -1800 6.7 10.0 1801 -2400 6.7 10.5 DAILY VALUE 6.7 9.9 0001 -0600 6.7 9.7 0601 -1200 6.5 9.3 6.6 9.2 1201 -1800 6.6 13 .1 6.6 9.5 1801 -2400 6.8 11.9 6.6 9.7 DAILY VALUE 6.6 11.4 6.6 9.5 0001 -0600 6.7 9.5 6.6 9.2 0601 -1200 6.6 9.6 6.5 8.6 1201 -1800 6.7 13.1 6.5 8.6 1801 -2400 6.8 12.2 6.6 8.6 DAILY VALUE ---6.7 11.1 6.5 8.8 0001 -0600 6.7 10.7 6.6 8.3 0601 -1200 6.6 10.4 6.6 8.1 1201 -1800 6.7 11.7 6.5 8.4 1801 -2400 6.7 11.2 6.6 8.9 DAILY VALUE 6.7 11.0 6.6 8.4 0001 -0600 6.6 10.0 ------------ 0601 -1200 6.6 10.0 MONTHLY VALUE 1201 -1800 6.7 11.7 ---------- 1801 -2400 6.8 11.6 DAILY VALUE 6.7 10.8 4-C-198 '--'. Table 4-C-58.Cont. -SEPTEMBER 1982 - -----------------------------------------------------~--------~-~------~---~~------DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 TIME INTRA-SURFACE INTRA-SURFACE INTRA-Sl,JRFACE INTRA-SURFACE PERIOD GRAVEL WATER GRAVEL WATER GRAVEL WATER GRAVEL WATER ----------------------------------------------------------~-----------------------~ 0001 -0600 6.7 8.7 6.3 8.1 6.0 7.0 6.1 4.5 0601 -1200 6.6 8.4 6.3 7.7 6.0 6.8 6.2 4.0 ~1201 -1800 6.6 8.9 6.3 7.7 5.9 6.8 6.2 4.3 1801 -2400 6.7 9.5 6.3 8.4 6.0 6.5 6.2 4.8 DAILY VALUE 6.6 8.9 6.3 8.0 6.0 6.8 6.2 4.4 0001 -0600 6.7 8.9 6.3 8.2 6.0 6.0 6.3 4.9 0601 -1200 6.6 8.0 6.3 7.4 5.9 5.8 6.3 4.8 1201 -1800 6.5 8.0 6.3 7.4 5.9 6.3 6.3 5.0 1801 -2400 6.4 8.7 6.3 8.4 5.9 6.4 6.4 5.2 ~DAILY VALUE 6.5 8.4 6.3 7.9 5.9 6.2 6.3 5.0 0001 -0600 6.4 8.7 6.3 8.0 5.9 6.0 6.4 5.1 0601 -1200 6.3 8.0 6.3 7.1 5.9 5.8 6.4 5.0-1201 -1800 6.3 7.7 6.2 6.8 5.9 6.0 6.4 5.2 1801 -2400 6.3 7.8 6.1 7.2 5.9 6.1 6.4 5.3 DAILY VALUE 6.3 8.1 6.2 7.3 5.9 6.0 6.4 5.1 ,,~,0001 -0600 6.3 7.6 6.1 6.7 5.9 5.9 6.4 4.6 0601 -1200 6.3 7.0 6.1 5.8 5.9 5.8 6.4 3.7 1201 -1800 6.2 7.2 6.1 5.8 5.9 6.1 ,6.4 3.6 1801 -2400 6.2 7.9 6.1 8.0 5.9 6.2 6.4 4.1....DAILY VALUE 6.3 7.4 6.1 6.6 5.9 6.0 6.4 4.0 0001 -0600 6.2 7.8 6.1 1.4 5.9 5.8 6.5 4.3 06"01 -1200 6.2 7.0 6.1 5.9 5.9 5.6 6.5 4.3 1201 -1800 6.2 7.2 6.1 6.4 5.9 5.8 6.5 4.7 1801 -2400 6.2 7.9 6.1 6.4 5.9 5.9 6.5 5.2 DAILY VALUE 6.2 7.5 6.1 5.0 5.9 5.8 6.5 4.6 0001 -0600 6.2 7.8 6.1 6.3 5.9 5.7 6.5 5.2 0601 -1200 6.2 7.2 6.0 6.2 6.0 5.5 6.5 4.9 1201 -1800 6.2 7.2 6.0 6.6 6.0 5.7 6.5 5.0 1801 -2400 6.2 7.6 6.0 6.7 6.0 5.8 6.5 5.5 DAILY VALUE 6.2 7.4 6.0 6.5 6.0 5.7 6.5 5.1 0001 -0600 6.3 7.5 6.0 6.5 6.0 5.1 0601 -1200 6.3 7.3 6.0 6.6 6.0 4.5 1201 -1800 6.2 7.8 6.0 7.8 6.0 4.9 1801 -2400 6.2 8.9 6.1 7.7 6.0 5.1 DAILY VALUE 6.2 7.9 6.0 7.2 6.0 4.9 0001 -0600 6.3 8.6 6.0 7.5 6.1 4.4 -------------- 0601 -1200 6.3 8.1 5.9 7.4 6.1 3.7 MONTHLY VALUE 1201 -1800 6.3 8.0 6.0 7.8 6.0 4.0 ---------------....1801 -2400 6.3 8.6 6.0 7.4 6.1 4.6 6.2 6.4 DAILY VALUE 6.3 8.3 6.0 7.5 6.1 4.2 ----------------------------------------------------------------------------------- 4-C-199 ~ Table 4-C-58.Cant.,-' -OCTOBER 1982 ------------------------------------------------------------------------------------ DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 TIME INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE PERIOD GRAVEL WATER GRAVEL WATER GRAVEL WATER GRAVEL WATER -----------------------------------------------------~---------------------------- 0001 -0600 6.5 5.3 6.2 1.7 5.7 1.4 5.1 2.4 ~ 0601 -1200 6.5 4.8 6.2 2.0 5.7 1.8 1201 -1800 6.4 4.7 6.2 3.3 5.6 2.2 1801 -2400 6.5 4.8 6.2 2.9 5.6 2.1 DAILY VALUE 6.5 4.9 6.2 2.5 5.6 1.9 0001 -0600 6.5 4.4 6.2 2.7 5.6 1.6 0601 -1200 6.5 3.9 6.1 2.7 5.6 1.6 1201 -1800 6.4 4.2 6.1 2.9 5.6 2.1 -1801 -2400 6.5 4.9 6.1 2.4 5.6 2.2 DAILY VALUE 6.5 4.4 6.1 2.7 5.6 1.9 0001 -0600 6.5 4.4 6.1 2.0 5.6 2.0 ~, 0601 -1200 6.4 3.7 6.1 1.9 5.5 1.7 1201 -1800 6.4 3.7 6.0 2.0 5.5 1.6 1801 -2400 6.5 4.5 6.1 1.8 5.5 1.8 ~, DAILY VALUE 6.4 4.1 6.1 1.9 5.5 1.8 0001 -0600 6.5 3.9 6.0 1.4 5.5 1.8 0601 -1200 6.4 2.9 6.0 1.9 5.5 1.9 ,~-1201 -1800 6.4 2.7 6.0 2.4 5.5 2.0 1801 -2400 6.4 3.8 6.0 2.2 5.5 1.8 DAILY VALUE 6.4 3.3 6.0 2.0 5.5 1.9 ~ 0001 -0600 6.4 2.9 6.0 1.6 5.4 1.5 0601 -1200 6.4 2.2 5.9 1.5 5.4 1.5 1201 -1800 6.4 2.3 5.9 1.8 5.4 1.6 1801 -2400 6.4 3.3 5.9 1.9 5.4 1.6 DAILY VALUE 6.4 2.7 5.9 1.7 5.4 1.5 0001 -0600 6.4 2.4 5.9 2.0 5.4 1.5 0601 -1200 6.4 1.7 5.9 2.5 5.4 1.4 1201 -1800 6.4 1.9 5.9 3.0 5.3 1.6 1801 -2400 6.4 3.1 5.9 2.6 5.3 1.5 DAILY VALUE 6.4 2.3 5.9 2.5 5.4 1.5 ~ 0001 -0600 6.4 2.7 5.9 1.9 5.3 1.4 0601 -1200 6.3 2.5 5.9 1.7 5.3 1.5 1201 -1800 6.3 2.3 5.9 2.1 5.3 1.7 1801 -2400 6.3 2.3 5.8 2.0 5.2 1.8 -DAILY VALUE 6.3 2.4 5.9 1.9 5.3 1.6 0001 -0600 6.3 1.9 5.8 1.7 5.2 1.8 ------------ 0601 -1200 6.3 2.0 5.8 1.6 5.2 2.0 MONTHLY VALUE 1201 ...1800 6.2 3.0 5.7 1.4 5.2 2.3 --.------------ 1801 -2400 6.3 2.1 5.7 1.3 5.1 2.4 5.9 2.4 DAILY VALUE 6.3 2.3 5.7 1.5 5.2 2.1 ------------------------------------------------------------------------------------ ~ 4-C-200 ~, Table·4-C-59.Mean intragravel and surface water temperature (C)datapod data summary at Slough 8A-Upper,RM 126.4,Geocode S30N03W20CDD.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals • -AUGUST 1982 - TIME PERIOD DAYS f -8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER 0001 -0600 4.8 5.8 0601 -1200 4.8 6.0 1201 -1800 4.8 6.9 1801 -2400 4.8 6.3 DAILY VALUE 4.8 6.2 0001 -0600 4.8 5.7 0601 -1200 4.8 6.1 1201 -1800 4.8 7.4 1801 -2400 4.8 6.6 DAILY VALUE 4.8 6.5 0001 -0600 4.8 5.5 0601 -1200 4.8 5.4 1201 -1800 4.9 6.6 1801 -2400 4.8 6.5 ,,-.,DAILY VALUE 4.8 6.0 0001 -0600 4.8 5.7 0601 -1200 4.8 5.6 1201 -1800 4.8 6.4 1801 -2400 4.8 6.4 DAILY VALUE 4.8 6.0 0001 -0600 4.8 5.9 0601 -1200 4.7 5.3 4.9 5.9 1201 -1800 4.8 8.3 4.9 6.1 1801 -2400 4.8 6.2 4.9 6.1 DAILY VALUE 4.8 6.6 4.9 6.0 0001 -0600 4.7 5.2 4.9 5.8-0601 -1200 4.7 5.3 4.9 5.8 1201 -1800 4.8 7.7 4.9 6.0 1801 -2400 4.8 6.4 4.9 5.9 DAILY VALUE 4.7 6.1 4.9 5.9 0001 -0600 4.8 5.9 4.9 5.7 0601 -1200 4.8 6.2 4.9 5.7 1201 -1800 4.8 7.0 4.9 6.0-1801 -2400 4.8 6.2 4.9 6.0 DAILY VALUE 4.8 6.3 4.9 5.8 0001 -0600 4.8 5.7 ------------- 0601 -1200 4.8 5.9 MONTHLY VALUE 1201 -1800 4.8 7.2 ------------ 1801 -2400 4.8 6.4 DAILY VALUE 4.8 6.3 4-C-201 4-C-203 Table 4-C-60.Mean intragrave1 and surface water temperature (C)datapod data summary at Slough 9,RM 128.7,Geocode S30N03W09DBC.A two part linear ~. equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. -AUGUST 1982 - "'" TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER DAYS 25 -31 INTRA-SURFACE GRAVEL WATER - 0001 -0600 3.5 7.9 0601 -1200 3.5 7.7 1201 -1800 3.5 8.7 1801 -2400 3.5 8.6 DAILY VALUE 3.5 8.2 0001 -0600 3.5 7.4 0601 -1200 3.5 7.6 1201 -1800 3.6 9.5 1801 -2400 3.5 9.2 DAILY VALUE 3.5 8.4 0001 -0600 3.5 7.0 0601 -1200 3.4 6.7 1201 -1800 3.5 9.1 1801 -2400 3.6 9.3 DAILY VALUE 3.5 8.0 0001 -0600 3.5 7.4 0601 -1200 3.5 6.6 1201 -1800 3.5 7.8 1801 -2400 3.5 8.4 DAILY VALUE 3.5 7.5 0001 -0600 -----3.5 7.6 0601 -1200 3.5 7.2 1201 -1800 3.6 10.9 3.5 7.6 1801 -2400 --3.6 9.5 3.6 7.8 DAILY VALUE 3.5 7.5 0001 -0600 3.5 6.4 3.6 7.2 0601 -1200 3.4 7.0 3.6 6.8 1201 -1800 3.6 10.5 3.6 7.0 1801 -2400 3.6 9.8 3.6 7.0 DAILY VALUE 3.5 8.4 3.6 7.0 0001 -0600 3.5 7.9 3.6 6.5 0601 -1200 3.5 7.9 3.6 6.3 1201 -1800 3.6 9.4 3.6 7.0 1801 -2400 3.6 9.0 3.7 7.4 DAILY VALUE 3.5 8.6 3.6 6.8 0001 ...0600 3.5 7.5 ---...-------- 0601 -1200 3.5 7.5 MONTHLY VALUE 1201 -1800 3.6 9.5 ------------ 1801 -2400 3.6 9.3 DAILY VALUE 3.5 8.5 4-C-204 ~ Table 4-C-60.Cont.A;,t ~ -OCTOBER 1982 ------------------------------------------------------------------------------------ DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 TIME INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE ~ PERIOD GRAVEL WATER GRAVEL WATER GRAVEL WATER GRAVEL WATER ----------------------------------------------------------------------------------- 0001 -0600 3.5 4.5 2.4 -2.2 3.1 2.3 2.9 1.6 ~ 0601 -1200 3.5 4.2 3.2 2.7 3.1 2.5 2.9 1.5 1201 -1800 3.5 4.1 3.2 3.4 3.1 2.8 2.9 1.5 1801 -2400 3.4 4.1 3.3 3.4 3.2 2.8 2.8 1.5 DAlLY VALUE 3.5 4.2 3.0 1.8 3.1 2.6 2.9 1.5 ""'" 0001 -0600 3.5 4.0 3 .3 3 .1 3.2 2.4 2.8 1.4 0601 -1200 3.4 3.7 3.3 3.0 3 .1 2.1 2.8 1.4 1201 -1800 3.4 3.8 3.3 3.2 3 .1 2.4 2.8 1.3 1801 -2400 3.4 4 .1 3.3 3 .1 3.1 2.6 2.8 1.4 DAlLY VALUE 3.4 3.9 3.3 3.1 3.1 2.4 2.8 1.4 0001 -0600 3.5 4.0 3 .3 2.8 3.2 2.6 2.8 1.3 ~, 0601 -1200 3.4 3.6 3.2 2.7 3.2 2.4 2.8 1.3 1201 -1800 3.4 3.6 3.2 2.9 3.1 2.4 2.7 1.2 1801 -2400 3.4 3.9 3.2 2.7 3.1 2.5 2.7 1.3 DAlLY VALUE 3.4 3.8 3.2 2.8 3.1 2.5 2.7 1.3 0001 -0600 3.4 3~8 3.2 2.3 3.1 2.5 2.7 1.2 0601 -1200 3.4 3.3 3.1 2.4 3.1 2.5 2.6 1.2 --,1201 -1800 3.3 3.1 3.2 2.7 3.1 2.5 2.6 1.2 1801 -2400 3.3 3.2 3.2 2.9 3.2 2.4 2.6 1.1 DAlLY VALUE 3.3 3.4 3.2 2.6 3.1 2.5 2.6 1.2 0001 -0600 3.3 3.1 3.2 2.7 3.1 2.1 2.6 1.1 0601 -1200 3.3 2.7 3.2 2.5 3.0 1.8 2.5 1.0 1201 -1800 3.3 2.6 3.2 2.6 3.0 1.9 2.5 1.1 1801 -2400 3.2 2.9 3.2 2.6 3.1 1.9 2.5 1.1 DAlLY VALUE 3.3 2.8 3.2 2.6 3.0 1.9 2.5 1.1 0001 -0600 3.3 2.9 3.2 2.5 3.0 1.7 2.5 1.1 0601 -1200 3.2 2.5 3.2 2.4 3.0 1.6 2.5 1.1 1201 -1800 3.2 2.4 3.2 2.7 3.0 1.7 2.6 1.1 1801 -2400 3.2 3.0 3.2 2.6 3.0 1.8 2.6 1.1 DAlLY VALUE 3.2 2.7 3.2 2.6 3.0 1.7 2.6 1.1 ~ 0001 -0600 3.3 3.2 3.1 2.1 3.0 1.7 2.5 1.1 0601 -1200 3.3 3.0 3.1 1.9 3.0 1.6 2.6 1.1 1201 -1800 3.3 3.0 3.1 2.2 3.0 1.6 2.6 1.1 1801 -2400 3.3 2.9 3.1 2.3 3.0 1.6 2.6 1.1 DAILY VALUE 3.3 3.0 3.1 2.1 3.0 1.6 2.6 1.1 0001 -0600 3.3 3.1 3.2 2.2 3.0 1.6 --------------- 0601 -1200 3.3 2.8 3.2 2.2 2.9 1.5 MONTHLY VALUE -1201 -1800 3.2 2.7 3.2 2.2 2.9 1.6 ------------- 1801 -2400 3.3 3.2 3.1 2.2 2.9 1.7 3.1 2.3 DAlLY VALUE 3.3 2.9 3.2 2.2 2.9 1.6 ---------------------------------------------------------------------------------- 4-C-206 Table 4-C-60.Cout • -NOVEMBER 1982 - -------~---------------------------------------------------------~---------------- TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 DAYS 25-31 INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER - 0001 -0600 2.6 1.2 2.6 1.3 0601 -1200 206 1.2 2.6 1.3 1201 -1800 2.6 1.3 2.7 1.4 1801 -2400 2.6 1.4 2.7 1.4 DAILY VALUE 2.6 1.3 2.6 1.3 0001 -0600 2.7 1.5 2.7 1.4 0601 -1200 2.7 1.7 2.7 1.5 1201 -1800 2.B 2.1 2.7 1.5 1801 -2400 2.8 2.0 2.7 1.4 ---- DAlLY VALUE 2.8 1.8 2.7 1.4 0001 -0600 2.8 1.6 2.7 1.3 0601 -1200 2.B 1.5 2.6 1.2 1201 -1800 2.8 1.7 2.6 1.3 1801 -2400 2.B 1.7 2.6 1.4 DAILY VALUE 2.8 1.6 2.6 1.3 0001 -0600 2.8 1.7 2.6 1.5 0601 -1200 2.8 1.7 2.7 1.6 1201 -1800 2.8 2.0 2.7 1.7 1801 -2400 2.9 1.8 2.8 1.7 DAILY VALUE 2.8 1.8 2.7 1.6 0001 -0600 2.8 1.6 2.8 1.7 0601 -1200 2.8 1.6 2.8 1.7 1201 -1800 2.8 1.8 2.8 1.8 1801 -2400 2.9 1.7 2.8 1.9 DAILY VALUE 2.8 1.7 2.8 1.8 0001 -0600 2.8 1.5 2.8 1.8 0601 -1200 2.8 1.4 2.8 1.9 1201 -1800 2.8 1.5 2.8 2.0 1801 -2400 2.8 1.4 DAILY VALUE 2.8 1.4 2.8 1.9 0001 -0600 2.8 1.3 0601 -1200 2.7 1.3 1201 -1800 2.7 1.4 1801 -2400 2.7 1.3 DAILY VALUE 2.7 1.3 0001 -0600 2.7 1.3 0601 -1200 2.7 1.3 1201 -1800 2.7 1.3 1801 -2400 2.7 1.2 DAILY VALUE 2.7 1.3 -_... }1ONTHLY VALUE 4-C-207 Table 4-C-61.Mean intragravel and surface water temperature (C)datapod data sUllUll3ry at Slough 11.RM 135.7.Geocode S31N02W30ADC.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. -AUGUST 1982 - ~, TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 INTRA-SURFACE GRA VEL WATER DAYS 17 -24 INTRA-SURFACE GRAVEL WATER DAYS 25 -31 INTRA-SURFACE GRAVEL WATER 0001 -0600 3.3 5.9 0601 -1200 3.4 6.0 1201 -1800 3.5 7.4 1801 -2400 3.6 7.3 DAILY VALUE 3.4 6.6 0001 -0600 3.6 6.4 ~ 0601 -1200 3.7 5.7 1201 -1800 3.6 4.4 1801 -2400 3.5 3.6 DAILY VALUE 3.6 5.1 0001 -0600 3.5 3.5 0601 -1200 3.5 3.4 1201 -1800 3.5 3.5 ~ 1801 -2400 3.5 3.4 DAILY VALUE 3.5 3.5 0001 -0600 3.5 3.5 ~, 0601 -1200 3.5 3.4 1201 -1800 3.5 3.4 1801 -2400 3.5 3.4 DAILY VALUE 3.5 3.4 ~ 0001 -0600 3.5 3.4 0601 -1200 3.3 5.4 3.5 3.4 -1201 -1800 3.3 8.3 3.5 3.4 I 1801 -2400 3.3 7.7 3.5 3.4 DAILY VALUE 3.3 7.1 3.5 3.4 ..... 0001 -0600 3.3 5.7 3.5 3.4 0601 -1200 3.3 5.7 3.5 3.4 1201 -1800 3.3 8.1 3.5 3.4 1801 -2400 3.3 7.5 3.5 3.4 DAILY VALUE 3.3 6.7 3.5 3.4 0001 -0600 3.3 6.5 3.4 3.4 0601 -1200 3.3 6.2 3.4 3.4 1201 -1800 3.3 6.9 3.4 3.4 1801 -2400 3.3 6.3 3.4 3.4 DAILY VALUE 3.3 6.5 3.4 3.4 0001 -0600 3.3 5.7 ------------- 0601 -1200 3.3 5.9 MONTHLY VALUE 1201 -1800 3.3 7.1 ------------- 1801 -2400 3.3 6.5 DAILY VALUE 3.3 6.3 4-C-208 4-C-209 Table 4-C-62.Nean intragravel and surface water temperature (C)datapod dala summary at Slough 16B,RM 138.0,Geocode S11N02W17AAA.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. -AUGUST 1982 - TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER ..... - ----------------------------------------------------------------------------------. .. 0001 -0600 6.2 6.0 0601 -1200 6.2 6.4 1201 -1800 6.8 7.4 1801 -2400 6.7 6.9 DAlLY VALUE 6.5 6.7 0001 -0600 6.2 6.0 0601 -1200 6.2 6.4 1201 -1800 6.8 7.5 1801 -2400 6.7 6.7 DAlLY VALUE 6.5 6.7 0001 -0600 ----.5.7 5.1 0601 -1200 5.2 4.9 1201 -1800 6.0 6.4 1801 -2400 6.1 6.2 DAILY VALUE 5.8 5.7 0001 -0600 5.3 5.1 0601 -1200 5.2 5.1 1201 -1800 ~5.9 6.2 1801 -2400 6.2 6.3 DAILY VALUE 5.7 5.7 0001 -0600 5.8 5.7 0601 -1200 5.0 5.1 5.7 5.7 1201 -1800 6.1 7.8 6.1 6.2 1801 -2400 6.2 6.3 6.1 6.2 DAILY VALUE 5.8 6.4 5.9 5.9 0001 -0600 5.3 4.7 5.8 5.7 0601 -1200 4.9 5.0 5.7 5.7 1201 -1800 6.1 7.4 5.9 6.1 1801 -2400 6.3 6.6 6.0 6.1 DAILY VALUE 5.7 5.9 5.8 5.9 0001 -0600 5.8 5.8 5.8 5.7 0601 -1200 5.9 6.2 5.7 5.8 1201 -1800 6.5 7.1 5.8 6.5 1801 -2400 6.2 6.3 6.0 6.6 DAILY VALUE 6.1 6.3 5.8 6.1 0001 -0600 5.7 5.5 -------------- 0601 -1200 5.8 6.0 MONTHLY VALUE 1201 -1800 6.8 7.3 -------------- 1801 -2400 6.7 6.8 DAILY VALUE 6.2 6.4 ---------------------------------------------------------------------~------------- 4-C-211 4--C~213 Table 4-C-63.Mean intragrave.1 and surface water temperature (C)datapod data summary at Slough 19,RM 140.0,Geocode S31N02W10DBA.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. -AUGUST 1982 .;;; '.."..'----------------------------------------------------------------------------------- TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 ..16 DAyS 17 ~24 DAYS 25 -31 INTRA~SURFAcE INTRA~SURFACE iNTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER ...,'..'.,'.'"..",-.'...,....,-'""------------------------------------------------------------------------------------ 0001 0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 1200 1201 -1806 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE ..;.---- -~-- -_....... ~- _._._- --- ------ ----- --- --------.,.~,- --'.------------_._-- ----- -----2~9 3.8 2.9 7.0 3.0 5.7 2.9 5.5 3.0 3.9 2.9 3.7 2.9 6.4 3.0 5.7 2.9 4.9 3.0 4.6 3;0 4.9 3.0 6.0 3 .0 5.3 3.0 5.2 3.0 4.3 3.0 4.6 3 .0 6.3 3.1 5.9 3.0 5.3 3.1 4.8 3.0 5.1 3.0 6.5 3.1 5.9 3.0 5.6 3.0 4.8 3.0 5.1 3.0 6.6 3.1 5.9 3.0 5.6 3.0 4.3 3.0 3.9 2.9 5.7 3.0 5.6 j.()4.9 3.0 4.4 3.0 4.2 3.0 5.2 3.0 5.4 3.0 4.8 3.b 4.7 3.0 4.6 3.0 5.2- 3.0 5.2 3.0 4.9 3.0 4.7 3.0 4.5 3.0 4.7 3.0 4.6 3.0 4.6 2.9 4.2 2.9 4.3 2.9 4.9 2.9 5.0 2.9 4.6 ------------- NONTHLY VALUE --------------- - """' f • -,.••----------------------------------------------------------------------------------- 4-C-214 ..... ,f'l~ Table 4-C-63.Cant.- -SEPTEMBER 1982 ------------------------------------------------------------------------------------ DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 TIME INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE PERIOD GRAVEL WATER GRAVEL WATER GRAVEL WATER GRAVEL WATER ----------------------------------------------------------------------------------- 0001 -0600 2.9 4.4 3.1 4.9 3.9 4.5 3.2 3.5 0601 -1200 2.9 4.4 3.1 4.4 3.8 4.4 3.2 3.4 !"""1201 -1800 3.0 5.1 3.1 4.6 3.9 4.6 3.2 3.7 1801 -2400 3 .1 5.1 3.1 5.2 3.8 4.4 3 .3 3.7 DAILY VALUE 3.0 4.7 3.1 4.8 3.9 4.5 3.2 3 .6 0001 -0600 3.1 4.3 3.1 4.5 3.7 4.1 3.3 3 .6 0601 -1200 3.0 4.2 3.1 4.1 3 .6 4.2 3.3 3.6 1201 -1800 2.9 5.0 3.1 4.4 3.7 4.5 3.3 3.7 1801 -2400 3.0 5.4 3.1 4.9 3 .6 4.3 3.4 3.8 DAILY VALUE 3.0 4.7 3.1 4.5 3.7 4.3 3 .3 3.7 0001 -0600 3.0 4.7 3 .1 4.3 3.5 4.0 3.3 3.6 0601 -1200 2.9 4.3 3.1 3.8 3.5 4.0 3.3 3•7 r-1201 -1800 209 4.7 3.0 4.0 3.5 4.2 3.4 3.9 1801 -2400 2.9 4.9 3.0 4.4 3.5 4.1 3.4 3.9 DAILY VALUE 209 4.6 3.0 4.1 3.5 4.1 3.4 3.8 ~'~"0001 -0600 2.9 4.5 3.0 4.0 3.5 4.0 3 .3 3.5 0601 -1200 2.9 4.2 3.0 3 .6 3.4 4.0 3.2 3.3 1201 -1800 2.9 4.8 3.0 3.7 3.5 4.3 3.2 3.5 i801 -2400 3.0 5.0 3.0 4.5 3.5 4.2 3.3 3.6 DAILY VALUE 2~9 4.6 3.0 4.0 3.5 4.1 3.2 3.5 0001 -0600 3.0 4.4 3.0 4.2 3.5 3.9 3.3 3.5 0601 -1200 2.9 4.0 3.1 3.9 3.5 4.0 3.3 3.5-,1201 -1800 2.9 4.6 3.0 3.9 3.6 4.2 3.4 3.7 1801 -')f·OO 3.0 5.0 3.0 4.5 3.5 4.1 3.4 3.8 DAILY VALUE 2.9 4.5 3.0 4.1 3.5 4.1 3.4 3.6 0001 -0600 3.0 4.5 3.0 4.1 3.5 3.9 3.4 3.6 0601 -1200 3.0 4.2 3.1 3.9 3.5 4.0 3.4 3.5 1201 -1800 3.0 4.5 3.1 4.8 3.5 4.3 3.7 ~1801 -2400 3.0 4.9 3.2 4.4 3.5 4.2 3.9 DAILY VALUE 3.0 4.5 3.1 4.3 3.5 4.1 3.7 0001 -0600 3.0 4.6 3.3 4.3 3.4 3.7 0601 -1200 3.0 4.5 3.3 4.4 3.3 3.6 1201 -1800 3.0 5.4 3.4 5.2 3.3 3.9 1801 -2400 3.1 6.1 3.5 4.7 3.3 3.9 DAILY VALUE 3.0 5.1 3.4 4.6 3.3 3.8 ~ 0001 -0600 3.2 5.2 3.5 4.4 3.2 3.5 --------------- 0601 -1200 3.2 4.5 3.5 4.6 3.2 3.4 MONTHLY VALUE 1201 -1800 3.1 4.8 3.8 5.2 3.3 3.8 --------------- 1801 -2400 3.1 5.3 4.0 4.8 3.3 3.8 3.2 4.2 DAILY VALUE 3.1 5.0 3.7 4.7 3.2 3.6 ----------------------------------------------------------------------------------- 4-C-215 Table 4-C-63.Cont. -OCTOBER 1982 - DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER 0001 -0600 3.7 .9 2.1 0601 -1200 3.6 2.7 .2.4 1201 -1800 3.8 3.2 2.7 1801 -2400 3.9 2.7 2.7 DAILY VALUE 3.8 2.4 2.4 0001 -0600 3.5 2.6 2.6 0601 -1200 3.3 2.7 2.7 1201 -1800 3.6 2.8 2.7 1801 -2400 3.9 2.6 2.4 DAILY VALUE 3.6 2.7 2.6 0001 -0600 3.4 2.7 2.0 0601 -1200 3.1 2.9 1.9 1201 -1800 3.4 3.0 2.0 1801 -2400 3.8 2.6 1.9 DAILY VALUE 3.5 2.8 1.9 0001 -0600 3.3 2.4 1.8 0601 -1200 2.9 2.5 1.8 1201 -1800 3.0 2.7 2.1 1801 -2400 3.4 2.4 2.2 DAILY VALUE 3.1 2.5 2.0 0001 -0600 3.0 2.1 2.3 0601-1200 2.7 2.4 2.5 1201 -1800 2.8 2.8 2.4 1801 -2400 3.0 2.5 2.1 DAILY VALUE 2.9 2.5 2.3 0001 -0600 2.7 2.3 1.9 0601 -1200 2.5 2.7 2.0 1201 -1800 2.7 3.2 2.2 1801 -2400 3.3 3.1 2.2 DAILY VALUE 2.8 2.8 2.1 0001 -0600 2.8 2.8 2.2 0601 -1200 2.6 3.0 2.3 1201 -1800 2.6 3.1 2.3 1801 -2400 3.0 2.9 2.2 DAILY VALUE 2.7 2.9 2.2 0001 -0600 2.7 2.6 2.2 0601 -1200 2.4 2.4 2.2 1201 -1800 2.5 2.3 2.4 1801 -2400 3.4 2.2 2.5 DAILY VALUE 2.8 2.4 2.3 TIME PERIOD DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER 2.5 ----- MONTHLY VALUE ~.,.-..------- --...2.7 4-C-216 - ~I .... -Table 4-C-64.Mean intragravel and surface water temperature (c)datapod data summary, at Slough 21-Mouth,RM 141.8,Geocode S31NOZW02AAB.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. ..SEPTEMBER 1982 - .----~--------------------------------------------------------------------- TIME PERIOD DAYS 1 -8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER GRAVEL WATER - 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 ..1800 1801 ..2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE ---- 6.9 6.7 6.9 6.8 6.4 6.3 6.7 6.6 5.9 5.8 5.5 5.4 5.5 5.3 4.9 4.6 5.4 5.3 4.6 5.0 4.4 5.4 3.8 5.1 3.7 4.9 4.1 5.1 3.6 4.8 3.7 5.0 3.7 5.1 3.7 4.7 3.7 4.9 3.7 4.6 3.6 5.1 3.6 5.2 3.7 4.8 3.7 4.9 3.6 4.2 3.7 4.2 3.6 4.5 3.6 3.8 3.6 4.2 3.6 3.2 3.6 3.0 3.7 3.7 3.6 3.4 3.6 3.3 3.6 2.7 3.6 2.9 3.6 3.7 3.6 3.6 3.6 3.2 3.6 3.1 3.6 3.2 3.6 3.8 3.6 3.8 3.6 3.5 3.7 3.5 3.7 3.6 3.7 3.8 3.6 3.7 3.7 3.6 3.6 3.5 3.6 3.7 3.6 4.0 3.6 3.6 3.6 3.7 3.6 2.9 3.7 2.9 3.7 3.4 3.6 3.6 3.7 3.2 3.7 3.4 3.7 3.5 3.7 3.9 3.7 3.9 3.7 3.7 3.7 3.6 3.7 3.6 3.7 4.0 3.7 4.0 3.7 3.8 MONTHLY VALUE ----------------------------------------------------------------------------------- 4-C-217 ,QI ~ Table 4-C-64.cont.,.' """I ...OCTOBER 1982 - -------------~----~~--------~---..----~---------------~~-----------------------DAYS 1 -8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 TIME INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE ~ PERIOD GRAVEL WATER GRAVEL WATER GRAVEL WATER GRAVEL WATER---------------------____~-"'--,-_~e~~-~---------~---__-__--~------------------- 0001 -0600 3.7 3.6 3.6 2.3 3.6 2.4 3.7 1.1 0601 -1200 3.7 3.5 3.6 2.1 3.7 2.8 1201 -1800 3.7 3.7 3.6 2.9 3.7 2.8 1801 -2400 3.7 3.7 3.6 3.4 3.7 2.2 DAILY VALUE 3.7 3.6 3.6 2.7 3.7 2.5 0001 -0600 3.7 3.4 3.6 2.6 3.7 1.7 0601 -1200 3.7 3.4 3.6 2.7 3.7 1.9 1201 1800 3.7 3.8 3.7 2.9 3.7 2.2 ~- 1801 -2400 3.7 3.8 3.7 3.1 3.7 2.3 DAILY VALUE 3.7 3.6 3.7 2.9 3.7 2.0 -0001 -0600 3.7 3.3 3.7 2.6 3.7 2.2 0601 -1200 3.7 3.2 3.7 2.4 3.7 2.1 1201 -1800 3.7 3.6 3.7 2.8 3.7 2.4 1801 -2400 3.7 3.7 3.7 2.4 3.7 2.4 -DAILY VALUE 3.7 3.4 3.7 2.6 3.7 2.3 0001 -06&0 3.7 3.0 3.7 2.2 3.7 2.1 0601 -1200 3.7 2.5 3.7 2.6 3.7 2.0 1""""'-,1201 -1800 3.7 2.8 3.7 3.1 3.7 2.0 1801 -2400 3.7 3.1 3.7 2.7 3.6 1.6 DAILY VALUE 3.7 2.8 3'.7 2.6 3.7 1.9 ~ 0001 -0600 3.7 2.7 3.7 2.5 3.6 1.2' 0601 -1200 3.7 2.4 3.7 2.7 3.6 1.1 1201 -1800 3.7 2.5 3.7 2.8 3.6 1.0 1801 -2400 3.7 2.6 3.7 2.6 3.6 .8 DAILY VALUE 3.7 2.6 3.7 2.6 3.6 1.0 0001 -0600 3.7 2.3 3.6 2.3 3 •.6 .8 0601 -1200 3.7 2.2 3.7 2.5 3.6 .9 1201 -1800 3.7 2.7 3.7 3.0 3.6 1.2 1801 -2400 3.7 3.2 3.7 2.0 3.7 1.2 DAILY VALUE 3.7 2.6 3.7 2.5 3.6 1.0 0001 -0600 3.7 2.7 3.7 1.•4 3.6 1.0 0601 -1200 3.6 2.5 3.6 1.4 3.6 .9 1201 -1800 3.7 2.7 3.6 1.8 3.6 1.0 1801 -2400 3.7 3.0 3.6 1.7 3.6 .8 DAlLY VALUE 3.7 2.7 3.6 1.6 3.6 .9 0001 -0600 3.7 2.7 3.6 1.9 3.6 .7 ------------0601 -1200 3.7 2.6 3.6 2.2 3.6 1.0 MONTHLY VALUE 1201 -1800 3.6 2.9 3.6 2.2 3.6 1.3 --------------1801 -2400 3.6 3.3 3.6 2.2 '3.6 1.3 3.7 2.3 DAILY VALUE 3.6 2.9 3.6 2.1 3.6 1.1 -------~~-----------~-------------~------~------------~-------------------------- ~, 4-C-218 ..... - Table 4-C-65.Mean intragravel and surface water temperature (C)atapod data summary at Slough 21-Upper,RM 142.0,GeocQde S32N02W36CCC.A two part linear equation interpolation method was used in order to "correct"readings from actual 6 hour,3 minute and 42 second time intervals to 6 hour intervals. -AUGUST 1982 - ..... - TIME PERIOD 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE DAYS 1 - 8 INTRA-SURFACE GRAVEL WATER DAYS 9 -16 DAYS 17 -24 INTRA-SURFACE INTRA-SURFACE GRAVEL WATER GRAVEL WATER 3.7 4.6 3.7 7.2 3.7 5.3 3.7 5.7 3.7 4.2 3.7 4.5 3.7 6.8 3.7 5.6 3.7 5.3 3.8 5.0 3.7 5.2 3.7 6.2 3.8 5.3 3.7 5.4 3.8 4.8 3.9 5.2 4.2 6.6 4.1 5.9 4.0 5.6 4-C-219 DAYS 25 -31 INTRA-SURFACE GRA VEL WATER 4.0 5.2 4.1 5.6 4.3 6.8 4.2 6.0 4.1 5.9 4.1 5.2 4.1 5.7 4.3 6.9 4.2 6.0 4.2 5.9 4.0 4.6 4.0 4.8 4.2 6.2 4.1 5.8 4.1 5.4 4.0 4.8 4.0 4.8 4.1 5.7 4.1 5.6 4.0 5.2 4.0 4.9 4.0 5.0 4.0 5.6 4.0 5.4 4.0 5.2 4.0 5.0 4.0 5.0 4.0 5.2 4.0 5.1 4.0 5.1 3.9 4.8 3.9 4.9 4.0 5.5 4.0 5.5 4.0 5.2 -------------- MONTHLY VALUE ----------- 4-C-220 ~~ ~~, Table 4-C-65.Cont. """ -OCTOBER 1982 ---.-------------------------------------------------------------------------------- DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 TIME INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE INTRA-SURFACE PERIOD GRAVEL WATER GRAVEL WATER GRAVEL WATER GRAVEL WATER ----------------------------------------------------------------------------------- r- 0001 -0600 3.9 3.7 3.5 .9 3.6 2.7 3.4 2.2 0601 -1200 3.8 3.5 3.6 3.0 3.7 3.0 1201 -1800 3.9 3.7 3.8 3.5 3.7 3.1 1801 -2400 3.9 3.8 3.6 3.0 3.6 2.8 DAILY VALUE 3.9 3.7 3.6 2.6 3.6 2.9 0001 -0600 3.8 3.5 3.6 2.9 3.5 2.5 0601 -1200 3.8 3.4 3.7 3.1 3.5 2.6 1201 -1800 3.9 3.7 3.7 3.3 3.6 '1..7 1801 -2400 4.0 3.9 3.6 2.9 3.6 2.8 DAILY VALUE;3.9 3.6 3.7 3.0 3.6 2.6 0001 ..0600 3.8 3.5 3.5 2.7 3.6 2.7 0601 -1200 3.7 3.3 3.6 2.8 3.6 2.7 1201 -1800 3.8 3.6 3.7 3.0 3.6 2.7 1801 -2400 4.0 3.8 3.5 2.8 3.6 2.8 DAILY VALUE 3.8 3.6 3.6 2.8 3.6 2.7 ~,~0001 -0600 3.7 3.2 3.5 2.6 3.5 2.7 0601 -1200 3.6 ·2.7 3.6 2.8 '3.5 2.6 1201 -1800 3.6 2.9 3.7 3.1 3.5 2.7 1801 -2400 3.8 3.4 3.6 3.0 3.5 2.5 -- ~DAILY VALUE 3.7 3.1 3.6 2.9 3.5 2.6 0001 -0600 3.6 2.9 3.5 2.8 3.4 2.3 0601 -1200 3.5 2.7 3.6 2.9 3.4 2.3 ~1201 -1800 3.5 2.7 3.6 3.0 3.5 2.3 1801 -2400 3.6 3.1 3.6 2.9 3.5 2.2 DAILY VALUE 3.6 2.9 3.6 2.9 3.5 2.3 -0001 -0600 3.5 2.6 3.6 2.7 3.5 2.1 0601 -1200 3.4 2.5 3.6 2.8 3.5 2.2 1201 ..1800 3.6 2.8 3.7 3.1 3.5 2.3 1801 -2400 3.8 3.4 3.6 2.7 3.5 2.3-DAlLY VALUE 3.6 2.8 3.6 2.8 3.5 2.2 0001 -0600 3.7 2.9 3.5 2.4 3.5 2.2 0601 ...1200 3.5 2.7 3.5 2.4 3.5 2.2 1201 -1800 3.6 2.8 3.6 2.6 3.5 2.2 1801 -2400 3.7 3.2 3.5 2.5 3.4 2.2 DAILY VALUE 3.6 2.9 3.5 2.5 3.5 2.2 ("'!}~0001 -0600 3.6 2.9 3.5 2.5 3.4 2.1 --------------- 0601 -1200 3.5 2.7 3.5 2.6 .3.5 2.2 MONTHLY VALUE 1201 -1800 3.6 3.0 3.6 2.7 3.5 2.4 ------------- 1801 -2400 3.8 3.5 3.6 2.7 3.4 2.4 3.6 2.8 DAILY VALUE 3.6 3.0 3.6 2.6 3.5 2.3 --------------------------------------------------------~-------------------------- 4-C-221 Table 4-C-66.Thermograph data summary,winter surface water temperature (C), Whiskers Creek Slough,RM 101.2,Geocode S26N05W03ADB. -FEBRUARY 1982 - -------------------------------------~------------------------------------------ TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX ..... 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001-0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 -2400 DAILY VALUE 0.0 0.0 0.0 0.0 0.0 0.0 .5 .5 .5 .5 .5 .5 0.0 .3 .5 0.0 .2 .5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 .0 .5 .5 .5 .5 .5 .7 1.0 ----1.0 La 1.0 1.0 1.0 1.0 .5 .8 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 ----1.0 1.0 1.0 1.0 1.0 1.0 ---- 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 .5 .7 1.0 --------------- 0.0 0.0 0.0 MONTHLY VALUE 0.0 0.0 0.0 --------------- 0.0 0.0 0.0 0.0 ---1.5 0.0 .2 1.0 I~ ...... ----------------------------~--------------------------------------------------- 4--C-222 ~, --Tab Ie 4-C-66.Cant. -MARCH 1982 --------------------------------------------------------------------------------- ~.TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX-------------------------------------------------------------------------------- 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0601-1200 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 -1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1801 -2400 1.0 1.0 l.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAlLY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 .1.5 1.5 1.5 0601 -1200 1.0 1.0 1.0 1.5;1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 -1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1801 -2400 1.0 1.0 1.0 1.5 .1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAlLY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0601 -1200 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 -1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 """1801-2400 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5:DAILY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 !""",-0601 -1200 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 ~1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1801 -2400 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAlLY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0601 -1200 LO 1.0 1.0 .1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 f""'\1201 -1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1801 -2400 LO 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAlLY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 """'0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5I 0601 ~1200 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 -1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1801 -2400 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAlLY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 ~0601 -1200 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 -1800 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1801 -2400 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAlLY VALUE 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0001 -0600 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 ------------- 0601 -1200 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 MONTHLY VALUE 1201 -1800 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 -------------- 1801 -2400 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.0 1.4 1.5 DAILY VALUE 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 ------.-~----------------------------------------------------------------------- 4-C-223 4-C-224 Table 4-C-66.Cont. -MAY 1982 - ----------------~------------------.--------------------------------------------TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX - -------~------------------------------------------------------------------------ 0001 0600 2.0 2.0 2.0 0601 1200 2.0 2.0 2.0 1201 1800 2.0 2.0 2.0 1801 2400 2.0 2.0 2.0 DAILY VALUE 2.0 2.0 2.0 0001 0600 1.5 1.7 2.0 0601 1200 1.5 1.5 1.5 1201 1800 1.5 1.8 2.0 1801 2400 1.5 1.5 1.5 --'-- DAILY VALUE 1.5 1.6 2.0 0001 0600 1.5 1.5 1.5 0601 1200 1.5 1.5 1.5 1201 1800 1.5 1.5 1.5 1801 2400 1.5 1.5 1.5 DAILY VALUE 1.5 1.5 1.5 0001 0600 1.5 1.5 1.5 0601 1200 1.5 1.5 1.5 1201 1800 1.5 1.5 1.5 1801 2400 1.5 1.5 1.5 DAILY VALUE 1.5 1.5 1.5 0001 0600 1.5 1.5 1.5 0601 1200 1.5 1.5 1.5 1201 1800 1.5 1.5 1.5 1801 2400 1.5 1.5 1.5 DAILY VALUE 1.5 1.5 1.5 0001 0600 1.5 1.5 1.5 0601 1200 1.5 1.5 1.5 1201 1800 1801 2400 DAILY VALUE 1.5 1.5 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 --------------- 0601 1200 MONTHLY VALUE 1201 1800 --.------------ 1801 2400 1.5 ----2.0 DAILY VALUE 4-C-225 Table 4-C-67.Thermograph data summary,winter surface water temperature (C), Slough 9B,RM 129.0,Geocode S30N03W16ABB. -FEBRUARY 1982 - ------------------------------~~---~--------------------.--------------~--------TIME PERIOD DAYS 1 -:8 MIN MEAN MAX D~;YS9 -16 MINMEAN MAX DAYS 17 -24 MIN MEAN MAX PAYS 25 -31 MIN MEAN MAX ------~--------~---------~--~-~---~~------.-------~~~---,--------------------- 0001 0600 --0601 1200 ------ 1201 1800 -'--~--~- 1801 2400 ..........--_..--...._-,;""i,_"" DAILY VALUE ---- 0001 Q600 --'I"'"---- 0601 120.0 ~-----...---"_'---~- 1201 ~&OO -----~--------- 1B01 2400 '----...0;._------- DAILY VALUE -_._-------- 0001 0600 ----~.----- 0601 1200 --------------.-...1.3 1.3 1201 1800 ~--------1.3 1.3 1.3 1801 2400 -~-t'"1.3 1.3 1.3 DAILY VALUE ~----1.3 1.3 0001 060Q ~'----1.3 1.3 1.3 0.601 1200 ----~1.3 1.3 1.3 .--1201 1800 ---~...1.3 1.5 loB 1801 2400 -,---loB loB 1.B DAILY VALUE ----1.3 1.5 1.8 0001 0600 OpOl 1200 --------1201 1800 --'''''',.....------ 1801 2400 -~-...-.0..-__ -~...---- DAILY VALUE --------.. 0001 0600 ---0601 1200 1201 1800 "------~ 1801 2400 DAILY VALUE ----,...---lIP-'! 0001 0600 0601 1200 1201 1800 ---~-------~- 1801 2400 --- DAILY VALUE 0001 0600 ------------ 0601 1200 MONTHLY VALUE 1201 1800 ,..-------------- 1801 2400 1.3 ---1.8 ~ DAILY VALUE --------.-. ------------------------~-----~----~------~----------~------~-~-----------------.\ ~ 4-C-226 - ~ Table 4--C-67.Cont. ~ -MARCH 1982 - ---------------------------------------------------------------------------------TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 1.8 1.8 1.8 1.8 1.8 1.8 2.3 2.3 2.3 1.8 1.8 1.8 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.3 1.8 1.8 1.8 1201 ~1800 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 ~1801 -2400 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 DAILY VALUE 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.3 1.8 1.8 1.8 0001 -0600 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8.1.8 1.8_. 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1201 -1800 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.3 2.6 2.8 1801 -2400 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.1 2.3 DAILY VALUE 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.1 2.8 0001 -0600 1.8 1.8 1.8 1.8 ·1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.3 1201 -1800 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.1 3.3 1801 -2400 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.0 3.3 DAILY VALUE 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 L8 2.5 3.3 ~0001 -0600 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 2.8 2.8 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 2.8 2.8 1201 -1800 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 3.3 3.6 3.8 1801 -2400 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.1 3.3 p~DAILY VALUE 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.1 3.8 0001 -0600 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 2.8 2.8 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 2.8 2.8 1201 -1800 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 3.3 3.6 3.8 1801 -2400 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.1 3.3 DAILY VALUE 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.1 3.8 ~ 0001 -0600 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 2.8 2.8 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.0 3.3 1201 -1800 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 3.3 3.6 3.8.-1801 -2400 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.3 3.8 DAILY VALUE 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.2 3.8 0001 -0600 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 2.8 2.8 0601 -1200 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.8 3.0 3'.3 1201 -1800 1.8 1.8 1.8 2.3 2.3 2.3 1.8 1.8 1.8 3.8 3.8 3.8 1801 -2400 1.8 2.0 2.3 2.3 2.3 2.3 1.8 1.8 1.8 2.8 3.3 3.8 i"""1 DAILY VALUE 1.8 1.8 2.3 1.8 2.0 2.3 1.8 1.8 1.8 2.8 3.2 3.8 0001 -0600 1.8 1.8 1.8 2.3 2 .3 2.3 1.8 1.8 1.8 _.-_---------- 0601 -1200 1.8 1.8 1.8 2.3 2.3 2.3 1.8 1.8 1.8 MONTHLY VALUE 1201 -1800 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 -------------- 1801 -2400 1.8 1.8 1.8 2.3 2.3 2.3 1.8 2.1 2.3 1.8 2.0 3.8 DAILY VALUE 1.8 1.8 1.8 2.3 2.3 2.3 1.8 2.0 2.3 ,....,------------------------------------------------------------------------------- -4--C-227 Table 4-C-67.Cont."""1,_c -APRIL 1982 ---------'------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX iIllP!l ------------------------------------------------------------------------------- 0001 -0600 2.8 2.8 2.8 2.8 2.8 2.8 3.3 3.3 3.3 3.8 4.1 4.3 0601 -1200 2.8 3.0 3.3 2.8 3.0 3.3 3~3 3.5 3.8 4.3'5.1 5.8 -1201 -1800 3.8 3.8 3.8 3.8 4.1 4.3 4.3 4.6 4.8 6.8 6.8 6.8 1801 -2400 2.8 3.0 3.3 3.3 3.6 3.8 3.8 4.3 4.8 5.3 6.0 6.8 DAILY VALUE 2.8 3.1 3.8 2.8 3.4 4.3 3.3 3.9 4.8 3.8 5.5 6.8 0001 -0600 2.8 2.8 2.8 2.8 2.8 2.8 3.3 3.3 3.3 4.8 4.8 4.8 0601 -1200 2.8 2.8 2.8 2.8 3.1 3.3 3.3 3.5 3.8 4.8 5.5 6.3 1201 -1800 3.3 3.6 3.8 4.3 4.3 4.3 4.3 4.3 4.3 7.3 7.3 7.3 1801 -2400 2.8 3.0 3.3 3.3 3.6 3.8 3.3 4.0 4.3 4.8 6.0 6.8 DAILY VALUE 2.8 3.0 3.8 2.8 3.5 4.3 3.3 3.8 4.3 4.8 5.9 7.3 0001 -0600 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 3.8 4.0 4.3 0601 -1200 2.8 3.0 3.3 2.8 3.3 3.8 2.8 3.3 4.3 3.8 4.8 5.8 1201 -1800 3.8 3.8 3.8 4.3 4.3 4.3 4.8 4.8 4.8 6.8 7.1 7.3 1801 -2400 2.8 3.0 3.3 3.3 3.8 4.3 2.8 3.5 4.3 5.8 6.6 7.3 DAILY VALUE 2.8 3.1 3.8 2.8 3.5 4.3 2.8 3.6 4.8 3.8 5.6 7.3 0001 -0600 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 4.3 4.5 4.8 0601 -1200 2.8 3.0 3.3 2.8 3.3 3.8 2.8 3.3 4.3 4.3 5.6 6.8 ~,.~1201 -1800 3.8 3.8 3.8 4.3 4.6 4.8 5.3 5.3 5.3 7.8 8.1 8.3 1801 -2400 2.8 3.3 3.8 3.3 3.8 4.3 4.3 4.8 5.3 5.8 6.8 7.8 DAILY VALUE 2.8 3.2 3.8 2.8 3.6 4.8 2.8 4.0 5.3 4.3 6.3 8.3 0001 -0600 2.8 2.8 2.8 2.8 2.8 2.8 3.3 3.5 3.8 4.8 4.8 4.8 0601 -1200 2.8 3.0 3.3 2.8 3.1 3.8 3.3 4.0 4.8 4.8 5.5 5.8 1201 -1800 3.8 3.8 3.8 4.8 4.8 4.8 5.3 5.3 5.3 8.8 9.1 9.3 1801 -2400 2.8 3.3 3.8 3.3 3.8 4.3 4.8 5.1 5.3 5.3 6.8 8.3 ~ DAILY VALUE 2.8 3.2 3.8 2.8 3.6 4.8 3.3 4.5 5.3 4.8 6.5 9.3 0001 -0600 2.8 2.8 2.8 2.8 2.8 2.8 3.3 3.6 3.8 4.8 4.8 4.8 0601 1200 2.8 3.0 3 ~3 2.8 3.5 4.3 3.3 4.0 4.8 4.8 5.5 5.8 ~- 1201 -1800 3.8 3.8 3.8 4.8 4.8 4.8 5.8 5.8 5.8 6.8 7.8 8.8 1801 -2400 3.3 3.5 3.8 3.8 4.1 4.3 4.8 5.5 5.8 5.8 7.1 8.3 DAILY VALUE 2.8 3.3 3.8 2.8 3.8 4.8 3.3 4.7 5.8 4.8 6.3 8.8 .... 0001 -0600 2.8 2.8 2.8 3.3 3.5 3.8 3.8 4.3 4.8 ------ ---- 0601 -1200 2.8 3.0 3.3 3.3 3.5 3.8 3.8 4.6 5.3 ---------- 1201 -1800 3.3 3.6 3.8 4.8 4.8 4.8 5.8 5.8 5.8 ----------- 1801 -2400 3.3 3.5 3.8 3.8 4.3 4.8 4.8 5.3 5.8 ----------- DAILY VALUE 2.8 3.2 3.8 3.3 4.0 4.8 3.8 5.0 5.8 ----------- 0001 -0600 2.8 2.8 2.8 3.3 3.3 3.3 4.3 4.5 4.8 -------------- 0601 -1200 2.8 3.0 3.3 3.3 3.6 4.3 4.3 5.0 5.8 MONTHLY VALUE 1201 -1800 2.8 3.0 3.3 4.8 4.8 4.8 6.3,6.3 6.3 -------------- 1801 -2400 2.8 3.0 3.3 3.8 4.3 4.8 4.8 5.3 5.8 2.8 4.2 9.3 DAILY VALUE 2.8 2.9 3.3 3.3 4.0 4.8 4.3 5.3 6.3 -------------------------------------------------------------------------------- ~ 4-C-228 Table 4-C-67.Cont. -MAY 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX '"""I !AIllIIi 0001 0600 4.8 4.8 4.8 0601 1200 4.8 5.5 5.8 1201 1800 7.8 9.3 10.3 1801 2400 5.8 7.6 9.3 DAILY VALUE 4.8 6.8 10.3 0001 0600 4.8 5.0 5.3 0601 1200 4.8 5.6 6.8 1201 1800 8.8 9.5 9.8 1801 2400 5.3 7.1 8.8 DAILY VALUE 4.8 6.8 9.8 0001 0600 4.3 4.8 5.3 0601 1200 4.8 5.3 5.8 1201 1800 6.8 7.6 8.3 1801 2400 5.3 6.5 7.8 DAILY VALUE 4.3 6.0 8.3 --- 0001 0600 3.8 4.1 4.8 0601 1200 3.8 5.0 6.3 1201 1800 7.8 9.0 9.8 1801 2400 4.3 6.5 8.3 DAILY VALUE 3.8 6.1 9.8 0001 0600 3.8 3.8 3.8 0601 1200 4.8 5.6 6.8 1201 1800 8.3 8.5 8.8 1801 2400 5.3 6.6 7.8 DAILY VALUE 3.8 6.1 8.8 0001 0600 4.3 4.6 4.8 0601 1200 5.3 6.0 6.8 1201 1800 1801 2400 DAILY VALUE 4.3 6.8 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 --------------- 0601 1200 MONTHLY VALUE 1201 1800 -------------- 1801 2400 3.8 ---10.3 DAlLY VALUE 4-C-229 Table 4-C-68.Thermograph data summary,winter surface water temperature (C), Slough 9-Be1ow tributary B,RM 129.0,Geocode S30N03W16ABC. -MARCH 1982 - -------------------------------------------------------------------------------- -; I TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 0001 0600 0601 1200 1201 1800 1801 24Q0 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 120J 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 -0600 Oq01 -1200 1201 --1800 1801 -2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE -.-- 1.1 1.4 1.6-1.1 1.3 1.6 ~--1.1 1.4 1.6 .6 .9 1.1 .6 1.3 1.6 .6 .6 .6 ~~.6 1.1 1.6 1.1 1.4 1.6 .6 .9 1.1 .6 1.0 1.6 .6 .6 .6 .6 .9 1.1 .6 .9 1.1 .6 .6 .6 .6 .8 1.1 .6 .6 .6 .6 .8 1.1 .6 .9 1.1 .6 .6 .6 .6 .7 1.1 ------------- MONTHLY VALUE ------------ .6 ---1.6 4-C-230 - ..... """'"Table 4-C-68.cont. F"" -APRIL 1982 - ---------------------------------------------------------------------------------TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN ~l4X MIN MEAN MAX MIN MEAN MAX.MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 .6 .6 .6 1.1 1.1 1.1 1.6 1.6 1.6 2.1 2.1 2.1 0601 -1200 .6 .8 1.1 1.6 1.8 2.1 1.6 2.1 2.6 3.1 3.6 4.1 1201 -1800 .6 .8 1.1 1.6 2.1 2.6 2.1 2.4 2.6 3.1 3.6 4.1 1801 -2400 .6 .6 .6 1.1 1.4 1.6 2.1 2.1 2.1 2.6 2.6 2.6 DAILY VALUE .6 .7 1.1 1.1 1.6 2.6 1.6 2.1 2.6 2.1 3.0 4.1 0001 -0600 .6 .6 .6 1.1 1.1 1.1 1.6 1.8 2.1 2.1 2.3 2.6 0601 -1200 .6 .8 1.1 1.1 1.6 2.1 1.6 2.1 2.6 2.6 3.9 5.1 1201 -1800 .6 .9 1.1 1.6 1.9 2.1 2.1 2.4 2.6 3.1 3.9 4.6 1801 -2400 .6 .6 .6 1.6 1.6 1.6 1.6 1.8 2.1 2.6 2.6 2.6 DAILY VALUE .6 .7 1.1 1.1 1.6 2.1 1.6 2.0 2.6 2.1 3.2 5.1 0001 -0600 .6 .6 .6 1.1 1.1 1.1 1.1 1.1 1.1 2.6 2.6 2.6 0601 -1200 .6 .6 .6 1.6 1.9 2.6 1.6 2.3 2.6 3.1 3.4 3.6 1201 -1800 .6 .9 1.1 1.6 2.1 2.6 2.1 2.4 2.6 3.1 3.8 4.1 1801 -2400 .6 .6 .6 1.1 1.3 1.6 1.6 1.6 1.6 2.6 2.6 2.6 DAILY VALUE .6 .7 1.1 1.1 1.6 2.6 1.1 1.8 2.6 2.6 3.1 4.1 "~"0001 -0600 .6 .6 .6 1.1 1.1 1.1 1.6 1.6 1.6 2.6 2.8 3 .1 0601 -1200 .6 .8 1.1 1.1 1.8 2.6 2.1 2.8 3 .6 3.1 3.9 4.6 1201 -1800 .6 .9 1.1 1.6 2.1 2.6 2.6 3 .1 3 .6 3.1 3.9 4.6 1801 -2400 .6 .6 .6 1.1 1.4 1.6 1.6 1.9 2.1 2.6 2.6 2 .6 DAILY VALUE .6 .7 1.1 1.1 1.6 2.6 1.6 2.3 3 .6 2.6 3 .3 4.6 0001 -0600 .6 .6 .6 1.1 1.1 1.1 2.1 2 .1 2.1 2.6 2.6 2.6 0601 ...1200 .6 .9 1.1 1.1 1.8 2.6 2.6 3.1 3.6 3.1 4.1 5.1 1201 -1800 1.1 1.4 1.6 1.6 2.1 2.6 2.6 2.8 3.1 3.1 3.9 5.1 1801 -2400 1.1 1.1 1.1 1.1 1.3 1.6 2.1 2.3 2.6 2.6 2.8 3.1 DAILY VALUE .6 1.0 1.6 1.1 1.6 2.6 2.1 2.6 3.6 2.6 3.3 5.1 ~ 0001 -0600 1.1 1.1 1.1 1.1 1.1 1.1 2.1 2.1 2.1 2.1 2.1 2.1 0601 -1200 1.1 1.4 1.6 1.6 1.9 2.J,2.6 3.3 4.1 3.1 3.9 4.6 1201 -1800 1.6 1.8 2.1 2.1 2.1 2.1 2.6 3.1 3.6 3.6 4.4 5.1 1801 -2400 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.9 2.1 2.6 2.8 3.1 DAILY VALUE 1.1 1.5 2.1 1.1 1.7 2.1 1.6 2.6 4.1 2.1 3.3 5.1 0001 -0600 1.1 1.4 1.6 1.6 1.6 1.6 2.1 2.1 2.1 ------------ 0601 -1200 1.6 1.6 1.6 1.6 2.1 2.6 2.6 3.3 3.6 ----------- 1201 -1800 1.6 1.8 2.1 2.1 2.4 2.6 2.6 3.1 3.6 ----------- 1801 -2400 1.1 1.1 1.1 1.6 1.8 2.1 2.1 2.1 2.1 ----------- DAILY VALUE 1.1 1.5 2.1 1.6 2.0 2.6 2.1 2.6 3.6 ----------- 0001 -0600 1.1 1.1 1.1 1.6 1.6 1.6 2.1 2.1 2.1 -------------- 0601 -1200 .6 1.1 1.6 1.1 1.8 2.6 L6 3.1 3.6 MONTHLY VALUE F""'.1201 -1800 1.1 1.4 1.6 2.6 2.8 J.1 2.6 3.1 3.6 -------------- 1801 -2400 1.1 1.1 1.1 1.6 1.9 2.1 2.1 2.3 2.6 .6 2.0 5.1 DAILY VALUE .6 1.2 1.6 1.1 2.0 3.1 2.1 2.6 3.6 ~-------------------------------------------------------------------------------- .....4-C-231 Table 4-C-68.cont. -MAY 1982 - -------------------------------------------------------------------------------- - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX ---------------------~-------------------------------------- -------------------- 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 2.1 2.1 2.1 ~3.1 4.4 5.6 4.1 4.9 5.6 3.1 3.1 3.1 2.1 3.6 5.6 2.6 2.8 3.1 3.6 4.4 5.1 4.1 5.1 6.1 2.6 2.9 3.1 2.6 3.8 6.1 ~ - !SlIIi\'J1", """ MONTHLY VALUE 2.1 ---6.1 4-C-232 Table 4-C-'"69.Thermograph data summary,winter surface water temperature (C), Slough 11,RM 135.3,Geocode S31N02W19DDD. -FEBRUARY 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX .~, .... 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 4--C-233 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.3 2.5 2.0 2.0 2.0 2.0 2.1 2.5 MONTHLY VALUE 2.0 ----2.5 4-C-235 Table 4-C-70.Thermograph data summary,winter surface water temperature (C), Slough 19,RM 140.0,Geocode S31N11 wl ODBB.._F ~-FEBRUARY 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 2S -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 -------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 --------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 --------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 -----------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE ------------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ..... 0001 -0600 ----------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 ------------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 -----------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 -----------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE ------------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 ----------2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 ----------2.3 2.3 2.3 2.3 2.3 2.3 1.8 1.8 1.8 1201 -1800 ---------2.3 2.3 2.3 2.3 2.3 2.3 1.8 1.8 1.8 1801 -2400 ----------2.3 2.3 2.3 2.3 2.3 2.3 1.8 1.8 1.8 DAILY VALUE ------------2.3 2.3 2.3 2.3 2.3 2.3 1.8 1.9 2.3 ~ 0001 -0600 -----------2.3 2.3 2.3 2.3 2.3 2.3 1.3 1.3 1.3 0601 -1200 ----------2.3 2.3 2.3 2.3 2.3 2.3 1.3 1.3 1.3 1201 -1800 --------2.3 2.3 2.3 2.3 2.3 2.3 1.3 1.3 1.3 ~.- 1801 -2400 --------2.3 2.3 2.3 2.3 2.3 2.3 1.3 1.3 1.3 DAILY VALUE ---------2.3 2.3 2.3 2.3 2.3 2.3 1.3 1.3 1.3 ~ 0001 -0600 ----------2.3 2.3 2.3 2.3 2.3 2.3 ----------- 0601 -1200 -----------2.3 2.3 2.3 2.3 2.3 2.3 --------- 1201 -1800 -----------2.3 2.3 2.3 2.3 2.3 2.3 ---------- 1801 -2400 -----------2.3 2.3 2.3 2.3 2.3 2.3 ----------- DAILY VALUE ------------2.3 2.3 2.3 2.3 2.3 2.3 ---------- 0001 -0600 -----------2.3 2.3 2.3 2.3 2.3 2.3 ----------- 0601 -1200 ----------2.3 2.3 2.3 2.3 2.3 2.3 ------------ 1201 -1800 ---------2.3 2.3 2.3 2.3 2.3 2.3 ----------- 1801 -2400 -----------2~3 2.3 2.3 2.3 2.3 2.3 ----------- DAILY VALUE -----------2.3 2.3 2.3 2.3 2.3 2.3 -----------jIllIQlI1l'o. 0001 -0600 ------------2.3 2.3 2.3 2.3 2.3 2.3 -------- ---- 0601 -1200 ----------2.3 2.3 2.3 2.3 2.3 2.3 ------- ---- 1201 -1800 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 ----------- 1801 -2400 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 -------- ---- DAILY VALUE 1.8 ----1.8 2.3 2.3 2.3 2.3 2.3 2.3 ----------- 0001 -0600 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 --------------- 0601 -1200 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 MONTHLY VALUE 1201 -1800 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 --------------- 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1.3 2.2 2.3 DAILY VALUE 1.8 1.9 2.3 2.3 2.3 2.3 2.3 2.3 2.3 -------------------------------------------------------------------------------- 4-C-236 ~ ..... , '--""Table 4-C-70.Cont. .... -MARCH 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX --------------------------------------------------------------------~----------- 0001 ..0600 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 ..1800 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 ..1200 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 ..1800 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ~-~'\0001 ..0600 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 ..1200 .8 .8 .8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 1.,3 1.3 1.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 ..2400 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE .8 1.2 1.8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 1.8 1.8 1.8 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 ..2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 1.8 2.2 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 2.3 2 '.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 ..2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 ..1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 ..1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 ..2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3,- 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 -------------- 0601 ..1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 MONTHLY VALUE 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 --------------- 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 .8 2.1 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 -----------------------------------------------------------------------~-------- 4-C-237 Table 4-C-70.Cont.""" """" ~ -APRIL 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ~ 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 Ml<I 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.8 2.8 2.8 ~1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.4 2.8 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 ..2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ~- 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ...., 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.5 2.8 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.8 2.8 2.8 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.5 2.8 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.6 3.3 ~ 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.8 3.3 3.8 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.5 2.8 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.7 3.8 ~ 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ----------- 0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ---------- 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ------------ 1801 -2400 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ------------ DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 -------- ---- 0001 -0600 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ---------------0601 -1200 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 MONTHLY VALUE 1201 -1800 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 ---------_-.._--- 1801 -2400 2.3 2.3 '2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 3.8 DAILY VALUE 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 -------------------------------------------------------------------------------- 4-C-238 Table 4-C-70.Cant. -MAY 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 2.3 2.3 2.3 2.3 2.6 3.3 3.3 3.6 3.8 2.3 2.6 2.8 2.3 2.8 3.8 2.3 2.3 2.3 2.3 2.8 3.3 3.3 3.6 3.8 2.3 2.5 2.8 2.3 2.8 3.8 2.3 2.3 2.3 2.3 2.8 3.3 3.3 3.3 3.3 2.3 2.6 2.8 2.3 2.8 3.3 2.3 2.3 2.3 2.3 3.3 3.8 3.3 4.0 4.3 2.3 2.6 2.8 2.3 3.0 4.3 2.3 2.3 2.3 2.3 3.1 3.8 3.3 3.6 3.8 2.3 2.6 2.8 2.3 2.9 3.8 2.3 2.3 2.3 MONTHLY VALUE -- - 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 2.3 2.3 4-C-239 2.3 ----4.3 ~ Table 4-C-71.Thermograph data summary,winter surface water temperature (C), Slough 21 Mouth,RM 142.0,Geocode S31NllW02AAA./"IIJ!iJ!>< ""'"-FEBRUARY 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN }fEAN MAX MIN MEAN MAX ~ -------------------------------------------------------------------------------- 0001 -0600 -----------2.0 2.2 2.5 3.0 3.0 3.0 1.0 1.0 1.0 0601 -1200 ---------2.0 2.0 2.0 3.0 3.0 3.0 1.0 1.0 1.0 1201 -1800 -----------2.0 2.0 2.0 3.0 3.0 3.0 1.0 1.0 1.0 1801 -2400 -----------2.0 2.0 2.0 2.5 2.8 3.0 1.0 1.0 1.0 DAILY VALUE -----------2.0 2.0 2.5 2.5 3.0 3.0 1.0 1.0 1.0 ~ 0001 -0600 -----------loS 1.5 1.5 2.5 2.5 2.5 1.0 1.0 1.0 0601 -1200 -----------1.5 1.5 1.5 2.5 2.5 2.5 1.0 1.0 1.0 1201 -1800 ------------loS 1.5 1.5 2.0 2.3 2.5 1.0 1.0 1.0 """1801 -2400 ---------loS 1.5 1.5 2.0 2.0 2.0 1.0 1.0 1.0 DAILY VALUE ------------loS 1.5 1.5 2.0 2.3 2.5 1.0 1.0 1.0 0001 -0600 -----------loS 1.5 1.5 2.0 2.0 2.0 1.0 1.0 1.0 -\ 0601 -1200 ----------1.5 1.5 1.5 2.0 2.0 2.0 1.0 1.2 1.5 1201 -1800 ------'----loS 1.5 1.5 1.5 1.7 2.0 1.5 1.5 1.5 1801 -2400 ------------loS 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAILY VALUE ------------loS 1.5 1.5 1.5 1.8 2.0 1.0 1.3 1.5 0001 -0600 ----------loS 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0601 -1200 -----------loS 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1201 -1800 ---------1.5 1.5 1.5 1.0 1.2 1.5 1.5 1.5 1.5 ,~- 1801 -2400 --------La 1.3 1.5 1.0 1.0 1.0 1.5 1.5 1.5 DAILY VALUE ---------1.0 1.5 1.5 1.0 1.3 1.5 1.5 1.5 1.5 ~ 0001 -0600 ---------1.0 1.0 1.0 1.0 1.0 1.0 ---------- 0601 -1200 -----------1.0 1.5 2.0 1.0 1.0 1.0 --------- 1201 -1800 -------- ----1.5 1.5 1.5 1.0 1.0 1.0 ----------- 1801 -2400 ---------1.5 1.5 1.5 1.0 1.0 1.0 ---------DAILY VALUE ------------1.0 1.4 2.0 1.0 1.0 1.0 --------- 0001 -0600 -----------1.5 1.5 1.5 1.0 1.0 1.0 ---------- 0601 -1200 -----------1.5 1.5 1.5 1.0 1.0 1.0 ------------ 1201 -1800 2.5 2.5 2.5 ----------1.0 1.0 1.0 ----------- 1801 -2400 2.5 2.5 2.5 1.5 1.5 1.5 1.0 1.0 1.0 ---------- DAILY VALUE 2.5 ---2.5 1.5 1.5 1.5 1.0 1.0 1.0 ------------ 0001 -0600 2.0 2.3 2.5 2.0 2.0 2.0 1.0 1.0 1.0 ----------- 0601 -1200 2.0 2.3 2.5 2.0 2.0 2.0 1.0 1.0 1.0 ---------- 1201 -1800 2.5 2.5 2.5 2.0 2.0 2.0 1.0 1.0 1.0 -----------~ 1801 -2400 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 ------- DAILY VALUE 2.0 2.3 2.5 2.0 2.0 2.0 1.0 1.0 1.0 ------------ 0001 -0600 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 --------------IIIiflll.f! 0601 -1200 2.0 2.2 2.5 2.0 2.2 2.5 1.0 1.0 1.0 MONTHLY VALUE 1201 -1800 2.0 2.0 2.0 3.0 3.0 3.0 1.0 1.0 1.0 -------------- 1801 -2400 2.5 2.5 2.5 3.0 3.0 3.0 1.0 1.0 1.0 1.0 1.6 3.0 lIII'fi'IlDAILYVALUE2.0 2.2 2.5 2.0 2.5 3.0 1.0 1.0 1.0 ---------------------------~---------------------------------------------------- 4-C-240 Tab 1e 4-C-71.Cont. -MARCH 1982 --------------------------------------------------------------------------------- TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 1.5 1.5 1.5 2.0 2.0 2.0 1.5 1.5 1.5 1.5 1.5 1.5 0601 -1200 1.5 1.5 1.5 2.0 2.0 2.0 1.5 1.7 2.0 2.0 2.0 2.0 1201 -1800 1.5 2.0 2.5 2.0 2.0 2.0 2.0 2.0 2.0 1.5 2.0 2.5 1801 -2400 2.0 2.2 2.5 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.3 2.0 DAILY VALUE 1.5 1.8 2.5 2.0 2.0 2.0 1.5 1.8 2.0 1.0 1.7 2.5 0001 -0600 1.5 1.7 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.7 2.5 0601 -1200 1.5 1.5 1.5 2.0 2.2 2.5 2.0 2.5 3.0 1.0 1.3 2.0 1201 -1800 1.5 1.5 1.5 2.0 2.3 2.5 2.5 2.8 3.0 2.0 2.3 2.5 1801 -2400 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 1.0 1.2 1.5 DAILY VALUE 1.5 1.5 2.0 1.5 2.0 2.5 2.0 2.5 3.0 1.0 1.6 2.5 0001 -0600 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.2 2.5 1.0 1.0 1.0 0601 -1200 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.3 2.5 1.5 2.0 2.5 1201 -1800 1.5 1.5 1.5 1.5 1.8 2.0 2.5 2.7 3.0 2.0 2.3 2.5 1801 -2400 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0 DAILY VALUE 1.5 1.5 1.5 1.5 1.6 2.0 2.0 2.3 3.0 1.0 1.8 2.5 piSI:I.~0001 -0600 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.0 2.0 1.5 1.7 2.0 0601 -1200 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.7 3.5 1.5 2.0 3.0 1201 -1800 2.0 2.0 2.0 1.5 1.5 1.5 3.0 3.2 3.5 2.0 2.8 3.5 1801 -2400 2.0 2.0 2.0 1.5 1.5 1.5 2.0 2.2 2.5 1.0 1.3 1.5 DAILY VALUE 1.5 1.7 2.0 1.5 1.5 1.5 2.0 2.5 3.5 1.0 2.0 3.5 0001 -0600 2.0 2.0 2.0 1.0 1.0 1.0 1.5 1.5 1.5 1.0 1.0 1.0 0601 -1200 2.0 2.0 2.0 1.0 1.2 1.5 2.0 2.0 2.0 1.0 1.7 2.5 1201 -1800 2.0 2.0 2.0 1.5 1.8 2.0 2.0 2.0 2.0 2.0 2.8 3.5 1801 -2400 2.0 2.0 2.0 1.0 1.0 1.0 2.0 2.0 2.0 1.5 1.5 1.5 DAILY VALUE 2.0 2.0 2.0 1.0 1.2 2.0 1.5 1.9 2.0 1.0 1.7 3.5 0001 -0600 2.0 2.0 2.0 1.0 1.0 1.0 2.0 2.0 2.0 1.0 1.0 1.0 0601 -1200 2.0 2.0 2.0 1.0 1.3 1.5 2.0 2.7 3.0 1.5 1.8 2.5 1201 -1800 2.0 2.3 2.5 1.5 1.8 2.0 2.0 2.5 3.0 1.5 2.3 3.0,....1801 -2400 2.0 2.0 2.0 1.5 1.5 1.5 2.0 2.0 2.0 1.0 1.2 1.5 DAILY VALUE 2.0 2.1 2.5 1.0 1.4 2.0 2.0 2.3 3.0 1.0 1.6 3.0 .0001 -0600 2.0 2.0 2.0 1.5 1.5 1.5 2.0 2.0 2.0 1.0 1.0 1.0 0601 -1200 2.0 2.3 2.5 1.5 2.0 2.5 2.0 2.5 3.0 1.0 1.5 2.0 1201 -1800 2.0 2.3 2.5 2.0 2.3 2.5 2.5 3.0 3.5 1.5 2.0 2.5 1801 -2400 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.2 2.5 1.0 1.0 1.0 DAILY VALUE 2.0 2.2 2.5 1.5 2.0 2.5 2.0 2.4 3.5 1.0 1.4 2.5 0001 -0600 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 --------------- 0601 -1200 2.0 2.3 2.5 2.0 2.2 2.5 2.5 2.7 3.0 MONTHLY VALUE 1201 -1800 2.5 2.5 2.5 2.0 2.3 2.5 2.0 2.7 3.5 -------------- 1801 ...2400 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.5 1.5 1.0 1.9 3.5 DAILY VALUE 2.0 2.2 2.5 2.0 2.1 2.5 1.5 2.2 3.5 -------------------------------------------------------------------------------- t+-C-241 Table 4-C-71.Cant.~ ,-, 1982 --APRIL -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX ~-------------------------------------------------------------------------------- 0001 -0600 1.0 1.0 1.0 1.5 1.7 2.0 2.0 2.2 2.5 3.0 3.2 3.5 0601 -1200 1.0 1.2 1.5 3.0 3.7 4.5 3.0 4.0 5.0 5.0 6.3 7.5 1201 -1800 1.0 1.5 2.0 2.5 3.5 4.5 3.5 4.7 6.0 4.0 5.3 6.0 1801 -2400 1.0 1.0 1.0 1.5 1.7 2.0 2.5 2.7 3.0 2.5 2.8 3.0 DAILY VALUE 1.0 1.2 2.0 1.5 2.6 4.5 2.0 3.4 6.0 2.5 4.4 7.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 2.0 2.2 2.5 2.0 2.2 2.5 0601 -1200 1.0 1.2 1.5 2.5 3.7 5.0 2.0 3.3 4.5 3.0 5.5 7.5 1201 -1800 1.5 1.8 2.0 3.0 4.0 5.0 3.0 4.0 5.0 3.5 5.7 7.5 1801 2400 1.0 1.2 1.5 2.0 2.2 2.5 1.5 1.8 2.0 3.0 3.0 3.0 ~- DAILY VALUE 1.0 1.3 2.0 1.5 2.8 5.0 1.5 2.8 5.0 2.0 4.1 7.5 0001 -0600 1.0 1.0 1.0 1.5 1.5 1.5 1.0 1.2 1.5 3.0 3.2 3.5 """i0601-1200 1.0 1.7 2.5 2.5 3.5 4.5 2.0 3.2 4.5 4.5 5.5 6.5 1201 -1800 2.0 2.2 2.5 2.5 3.5 4.5 2.5 3.7 4.5 4.5 5.8 6.5 1801 -2400 1.5 1.5 1.5 1.5 1.7 2.0 2.0 2.0 2.0 3 .0 3.2 3.5 DAILY VALUE 1.0 1.6 2.5 1.5 2.5 4.5 1.0 2.5 4.5 3.0 4.4 6.5 0001 -0600 1.5 1.5 1.5 1.0 1.2 1.5 2.0 2.0 2.0 3.0 3.2 3.5 0601 -1200 l.5 2.0 2.5 1.5 3.0 5.0 4.0 5.2 6.5 .5.0 6.0 6.5 1201 -1800 2.5 2.8 3.0 2.5 3.8 5.0 3.5 5.2 6.5 4.0 5.3 6.5 --1801 -2400 1.5 1.7 2.0 1.5 1.5 1.5 2.0 2.2 2.5 2.5 2.8 3.0 DAILY VALUE 1.5 2.0 3.0 1.0 2.4 5.0 2.0 3.6 6.5 2.5 4.3 6.5 0001 -0600 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.2 2.5 2.5 2.7 3.0 0601 -1200 1.5 2.3 3.5 1.5 3.2 5.0 4.0 5.7 7.5 4.0 5.7 6.5 1201 -1800 3.0 3.5 4.0 2.0 3.7 5.0 4.0 5.5 7.0 3.5 4.7 6.0 1801 -2400 2.0 2.2 2.5 1.0 1.3 1.5 2.5 2.8 3.0 2.0 2.2 2.5 -DAILY VALUE 1.5 2.4 4.0 1.0 2.4 5.0 2.0 4.0 7.5 2.0 3.8 6.5 0001 -0600 2.0 2.0 2.0 1.0 1.2 loS 2.5 2.7 3.0 2.0 2.2 2.5 0601 -1200 2.5 3.3 4.5 2.5 3.5 4.5 4.0 5.8 7.0 4.0 6.2 8.0 ~'. 1201 -1800 3.0 3.7 4.5 3.0 3.8 4.5 3.5 5.0 6.5 4.0 6.0 8.0 1801 -2400 2.5 2.5 2.5 2.0 2.5 3.0 2.0 2.3 3.0 2.0 2.3 3.0 DAILY VALUE 2.0 2.9 4.5 1.0 2.7 4.5 2.0 4.0 7.0 2.0 4.2 8.0 0001 -0600 2.5 2.5 2.5 2.0 2.0 2.0 2.0 2.3 3.0 ----------- 0601 -1200 2.5 3.8 5.0 3.0 4.3 5.5 4.5 5.3 6.0 ----------- 1201 -1800 3.0 3.5 4.0 3.0 4.3 5.5 3.5 4.8 6.0 -------- ---- 1801 -2400 2.0 2.2 2.5 2.0 2.2 2.5 2.5 2.8 3.0 ---- -------- DAILY VALUE 2.0 3.0 5.0 2.0 3.2 5.5 2.0 3.8 6.0 ----------- 0001 -0600 2.0 2.0 2.0 1.5 1.7 2.0 2.5 2.7 3.0 ------------ 0601 -1200 2.5 2.7 3.0 2.0 4.2 6.5 4.0 4.8 5.5 MONTHLY VALUE 1201 -1800 2.5 2.8 3.0 4.0 5.3 6.5 3.5 4.5 5.5 ---------- 1801 -2400 1.5 1.5 1.5 2.0 2.5 3.0 3.0 3.0 3.0 1.0 3.1 8.0 DAlLY VALUE 1.5 2.2 3.0 1.5 3.4 6.5 2.5 3.7 5.5 """ -------------------------------------------------------------------------------- 4·-C-242 Table 4-C-71.Cant. -MAY 1982- TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 2S -31 MIN MEAN MAX ------------------~----------------------------------------------------------- 0001 0600 1.5 1.7 2.0 0601 1200 4.0 6.8 9.0 1201 1800 4.5 6.7 8.5 !"""1801 2400 2.5 3.0 3.5 DAILY VALUE 1.5 4.5 9.0 0001 0600 2.5 2.7 3.0--0601 1200 4.0 5.5 7.0 1201 1800 3.5 5.5 7.0 1801 2400 2.0 2.3 2.5 DAILY VALUE 2.0 4.0 7.0 0001 0600 2.0 2.2 2.5 0601 1200 5.0 5.7 7.0 1201 1800 7.0 7.0 1801 2400 DAILY VALUE 2.0 7.0 ~,0001 0600 0601 1200 1201 1800 1801 2400 F DAILY VALUE --- 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800-1801 2400 DAILY VALUE 0001 0600-0601 1200 1201 1800 1801 2400 DAILY VALUE f"""" ! 0001 0600 0601 1200 ~1201 1800 1801 2400 DAILY VALUE '--- MONTHLY VALUE 1.5 ---9.0 4-C-243 """! Table 4-C-72.Thermograph data summary,winter surface water temperature (C), Slough-21 Middle,RM 142.0,Geocode S31NllW02AAA.~,-, -. -MARCH 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 0600 , .5 .5 .5 1.0 1.0 1.0 1.0 1.0 1.0------------- 0601 1200 .5 .8 1.0 1.0 1.0 1.0 1.5 1.5 1.5 ~------------- 1201 -1800 -----------1.0 1.0 1.0 1.0 1.0 1.0 .5 1.0 1.5 1801 -2400 --------.5 .8 LO 1.0 1.0 1.0 .5 .5 .5 DAILY VALUE ----------.5 .8 1.0 1.0 1.0 1.0 .5 1.0 1.5 0001 -0600 -----------.5 .7 1.0 1.0 1.0 1.0 .5 .5 .5 0601 -1200 --------1.0 1.0 1.0 1.0 1.3 1.5 .5 1.0 1.5 1201 -1800 -----------.5 .7 1.0 1.0 1.3 1.5 1.0 1.2 1.5 ~ 1801 -2400 ------------~5 .5 .5 1.0 1.2 1.5 1.0 1.0 1.0 DAILY VALUE -----------.5 .7 1.0 1.0 1.2 1.5 .5 .9 1.5 0001 -0600 ----------.5 .5 .5 1.0 1.2 1.5 1.0 1.0 1.0 0601 -1200 --------.5 .7 1.0 1.0 1.2 1.5 1.0 1.2 1.5 1201 -1800 -----------.5 .8 1.0 1.0 1.2 1.5 1.0 1.3 1.5 1801 -2400 ----------.5 .5 .5 1.0 1.0 1.0 1.0 1.0 1.0 .5 1.0 1.0 1.1 1.5 1.0 1.1 1.5 -DAILY VALUE -----------.6 0001 -0600 ---------.5 .5 .5 1.0 1.0 1.0 1.0 1.0 1.0 0601 -1200 ---------.5 .7 1.0 1.5 1.8 2.0 1.0 1.3 2.0 ~.-1201 -1800 --------.5 .8 1.0 1.5 1.8 2.0 1.0 1.5 2.0 1801 -2400 -----------.5 .5 .5 1.0 1.2 1.5 1.0 1.0 1.0 DAILY VALUE ----------.5 .6 1.0 1.0 1.5 2.0 1.0 1.2 2.0 0001 -0600 ---------.5 .5 .5 1.0 1.0 1.0 1.0 1.0 1.0 0601 -1200 --- --- ----.5 .5 .5 1.0 1.0 1.0 1.0 1.2 1.5 1201 -1800 ------------.5 .7 1.0 1.0 1.0 1.0 1.0 1.2 1.5 1801 2400 .5 .5 .5 1.0 1.0 1.0 .5 .8 1.0 ~------------- DAILY VALUE ----------.5 .5 1.0 1.0 1.0 1.0 .5 1.0 1.5 0001 -0600 -----------.5 .5 .5 1.0 1.0 1.0 .5 .5 .5 -0601 -1200 ----------.5 .5 .5 1.5 1.8 2.0 .5 1.0 1.5 1201 -1800 -----------.5 .8 1.0 1.5 1.5 1.5 1.0 1.2 1.5 1801 -2400 ---------.5 .8 1.0 1.5 1.5 1.5 1.0 1.0 1.0 DAILY VALUE -----------.5 .7 1.0 1.0 1.5 2.0 .5 .9 1.5 ,.... 0001 -0600 -----------1.0 1.0 1.0 1.5 1.5 1.5 1.0 1.0 1.0 0601 -1200 ---------1.0 1.2 1.5 1.5 1.7 2.0 1.0 1.2 1.5 1201 -1800 ------------1.0 1.0 1.0 1.5 1.8 2.0 1.0 1.2 1.5 .." 1801 -2400 ------------1.0 1.0 1.0 1.5 1.5 1.5 1.0 1.0 1.0 DAILY VALUE -----------1.0 1.0 1.5 1.5 1.6 2.0 1.0 1.1 1.5 0001 -0600 ------------1.0 1.0 1.0 1.0 1.0 1.0 -------------- 0601 -1200 --------1.0 1.0 1.0 1.5 1.7 2.0 MONTHLY VALUE 1201 -1800 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 2.0 -~------------1801 -2400 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 .5 1.0 2.0 DAILY VALUE 1.0 ----1.0 1.0 1.0 1.0 1.0 1.3 2.0 -------------------------------------------------------------------------------- ~~ 4-C-244 ~ ~,Table 4-C-72.Cont. -APRIL 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31....PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX.MIN MEAN MAX. ~------------------------------------------------------------------------------ 0001 -0600 .5 .5 .5 1.0 1.0 1.0 1.5 1.5 1.5 2.0 2.2 2.5 0601 -1200 1.0 1.0 1.0 1.5 2.3 3.0 2.0 2.8 3.5 3.0 3.8 4.5 1201 -1800 .5 .7 1.0 1.5 2.0 2.5 2.0 2.7 3.5 3.0 3.8 4.5 1801 -2400 .5 .5 .5 1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.2 2.5 DAILY VALUE .5 .7 1.0 1.0 1.6 3.0 1.5 2.2 3.5 2.0 3.0 4.5 0001 -0600 .5 .5 .5 1.0 1.0 1.0 1.5 1.5 1.5 2.0 2.0 2.0 0601 -1200 .5 .8 1.0 1.5 2.3 3.0 2.0 2.7 3.0 2.5 3.7 4.5 1201 -1800 .5 .8 1.0 1.5 2.0 2.5 1.5 2.2 3.0 2.5 3.7 5.0 1801 -2400 .5 .5 .5 1.0 1.0 1.0 1.0 1.3 1.5 2.0 2.0 2.0 DAILY VALUE .5 .7 1.0 1.0 1.6 3.0 1.0 1.9 3.0 2.0 2.8 5.0 0001 -0600 .5 .5 .5 1.0 1.0 1.0 .5 .8 1.0 2.0 2.2 2.5 0601 -1200 .5 1.0 1.5 1.5 2.3 3.0 1.5 2.3 3.0 3.0 3.5 4.0 1201 -1800 1.0 1.0 1.0 1.0 1.7 2.5 1.0 1.8 2.5 3.0 3.7 4.0 f"""1801 -2400 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.5 2.0 2.2 2.5 DAILY VALUE .5 .9 1.5 1.0 1.5 3.0 .5 1.5 3.0 2.0 2.9 .4.0 0001 -0600 .5 .8 1.0 1.0 1.0 1.0 1.5 .1.7 2.0 2.0 2.2 2.5 1""'-0601 -1200 1.0 1.2 1.5 1.0 2.2 3.0 2.5 3.7 4.5 3.5 4.0 4.5 1201 -1800 1.0 1.2 1.5 1.0 2.0 3.0 2.5 3.2 4.0 2.5 3.2 4.0 1801 -2400 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 2.0 1.5 1.8 2.0 DAILY VALUE .5 1.0 1.5 1.0 1.5 3.0 1.5 2.6 4.5 1.5 2.8 4.5 0001 -0600 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.8 2.5 1.5 1.5 1.5 0601 -1200 1.0 1.5 2.0 1.0 2.2 3.0 3.0 4.0 5.0 2.5 3.5 4.0 1201 -1800 1.0 1.5 2.0 1.0 1.8 3.0 2.5 3.3 4.0 2.0 2.8 3.5 1801 -2400 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.2 2.5 1.0 1.~1.5 DAILY VALUE 1.0 1.2 2.0 1.0 1.5 3.0 1.5 2.8 5.0 1.0 2.2 4.0 0001 -0600 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 2.0 1.0 1.2 1.5 0601 -1200 1.0 1.8 2.5 1.5 2.0 2.5 3.0 4.0 4.5 2.5 3.8 5.0 1201 -1800 1.5 1.7 2.0 1.5 1.8 2.0 2.5 3.3 4.0 2.5 3.5 4.5 1801 -2400 1.5 1.5 1.5 1.5 1.5 1.5 2.0 2.0 2.0 1.5 1.7 2.0 DAILY VALUE 1.0 1.5 2.5 1.0 1.6 2.5 2.0 2.8 4.5 1.0 2.5 5.0 0001 -0600 1.0 1.0 1.0 1.0 1.2 1.5 1.5 2.0 2.5 ----------- 0601 ~1200 1.5 2.2 2.5 2.0 2.8 3.5 3.0 3.5 4.0 ------------ 1201 -1800 1.5 1.8 2.0 1.5 2.3 3.0 2.5 3.0 3.5 ------------ 1801 -2400 1.0 1.0 1.0 1.0 1.3 1.5 2.0 2.0 2.0 ------------ DAILY VALUE 1.0 1.5 2.5 1.0 1.9 3.5 1.5 2.6 4.0 ------------ "...0001 -0600 1.0 1.2 1.5 1.0 1.2 1.5 2.0 2.2 2.5 --------------- 0601 -1200 1.5 1.5 1.5 1.5 3.0 4.0 3.0 3.3 3.5 MONTHLY VALUE 1201 -1800 1.0 1.5 2.0 2.0 3.0 4.0 2.5 3.0 3.5 --------------- 1801 -2400 1.0 1.0 1.0 1.5 1.7 2.0 2.0 2.0 2.0 .5 1.9 5.0 DAILY VALUE 1.0 1.3 2.0 1.0 2.2 4.0 2.0 2.6 3.5 -------------------------------------------------------------------------------- 4-C-245 Tab1e4-C-72.Cont. -MAY 1982 - - ..... TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 0001 0600 1.5 1.5 1.5 0601 1200 2.5 4.0 5.0 1201 1800 3.0 4.2 5.0 1801 2400 2.0 2.2 2.5 DAILY VALUE 1.5 3.0 5.0 0001 0600 2.0 2.0 2.0 0601 1200 3.0 3.8 4.5 1201 1800 2.5 3.8 5.0 1801 2400 2.0 2.0 2.0 DAILY VALUE 2.0 2.9 5.0 0001 0600 1.5 1.7 2.0 0601 1200 3.5 3.5 1201 1800 1801 2400 DAILY VALUE 1.5 3.5 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 ------------- 0601 1200 MONTHLY VALUE 1201 1800 --------------- 1801 2400 1.5---5.0 DAILY VALUE -------------------------------------------------------------------------------- 4-C-246 ~.,- - ·Table 4-C-73.Cont.- ~ -MARCH 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 - 16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 1.0 1.0 1.0 2.0 2.0 2.0 1.0 1.2 1.5 2.0 2.0 2.0 0601 1200 1.0 1.0 1.0 2.0 2.0 2.0 1.0 1.2 1.5 2.0 2.0 2.0 ~- 1201 -1800 1.5 1.5 1.5 2.0 2.0 2.0 1.5 1.8 2.0 1.5 1.8 2.0 1801 -2400 1.0 1.2 1.5 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 DAILY VALUE 1.0 1.2 1.5 2.0 2.0 2.0 1.0 1.5 2.0 1.0 1.7 2.0 ~ 0001 -0600 1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0 2.0 .5 .8 1.0 0601 -1200 1.0 1.0 1.0 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.2 1.5 1201 -1800 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.3 2.5 1.0 1.3 1.5 ~ 1801 -2400 1.0 1.0 1.0 1.0 1.3 1.5 2.0 2.0 2.0 .5 .8 1.0 DAILY VALUE 1.0 1.1 1.5 1.0 1.8 2.0 2.0 2.1 2.5 .5 1.0 1.5 0001 -0600 1.0 1.0 LO .5 .8 1.0 2.0 2.0 2.0 .5 .5 .5 0601 -1200 1.0 1.0 1.0 .5 .7 1.0 1.5 1.7 2.0 .5 .8 1.0 1201 -1800 1.0 1.3 1.5 1.5 1.5 1.5·2.0 2.0 2.0 1.0 1.3 1.5 1801 -2400 1.0 1.0 1.0 1.0 1.2 1.5 2.0 2.0 2.0 1.0 1.0 1.0 DAILY VALUE 1.0 1.1 1.5 .5 1.0 1.5 1.5 1.9 2.0 .5 .9 1.5 0001 -0600 .5 .5 .5 .5 .5 .5 2.0 2.0 2.0 .S .8 1.0 0601 -1200 .5 .8 1.0 1.0 1.2 1.5 2.0 2.0 2.0 .5 1.0 1.5 ~-1201 -1800 1.5 1.5 1.5 1.5 1.7 2.0 2.0 2.0 2.0 1.0 1.2 1.5 1801 -2400 1.5 1.5 1.5 1.0 1.0 1.0 2.0 2.0 2.0 .5 .5 .5 DAILY VALUE .5 1.1 1.5 .5 1.1 2.0 2.0 2.0 2.0 .S .9 1.5 ~ 0001 -0600 1.5 1.5 1.5 .5 .7 1.0 1.5 1.5 1.5 .5 .5 .5 0601 -1200 1.0 1.3 1.5 .5 .7 1.0 1.5 1.5 1.5 .5 .7 1.0 1201 -1800 2.0 2.0 2.0 1.0 1.3 1.5 1.5 1.7 2.0 .S .8 1.0 1801 -2400 1.5 1.7 2:0 .5 .7 1.0 2.0 2.0 2.0 .5 .5 .5 ~ DAILY VALUE 1.0 1.6 2.0 .5 .8 1.5 1.5 1.7 2.0 .5 .6 1.0 0001 -0600 1.5 1.5 1.5 .5 .5 .5 2.0 2.0 2.0 .5 .5 .5 -0601 -1200 1.5 1.7 2.0 .5 .7 1.0 2.0 2.2 2.5 .5 .7 1.0 1201 -1800 2.0 2.0 2.0 1.5 1.5 1.5 2.0 2.3 2.5 .5 .7 1.0 1801 -2400 2.0 2.0 2.0 1.0 1.0 1.0 2.0 2.0 2.0 0.0 0.0 0.0 DAILY VALUE 1.5 1.8 2.0 .5 .9 1.5 2.0 2.1 2.5 0.0 .5 1.0 - 0001 -0600 2.0 2.0 2.0 1.0 1.0 1.0 2.0 2.0 2.0 0.0 0.0 0.0 0601 -1200 2.0 2.0 2.0 1.0 1.2 1.5 2.0 2.2 2.5 0.0 .2 .5 1201 -1800 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.5 2.5 .5 .5 .5 J/Illll!!-, 1801 -2400 2.0 2.0 2.0 1.5 1.7 2.0 2.0 2.0 2.0 0.0 0.0 0.0 DAILY VALUE 2.0 2.0 2.0 1.0 1.5 2.0 2.0 2.2 2.5 0.0 .2 .5 0001 -0600 2.0 2.0 2.0 1.5 1.5 1.5 2.0 2.0 2.0 -------------- 0601 -1200 2.0 2.0 2.0 1.5 1.7 2.0 2.0 2.2 2.5 MONTHLY VALUE 1201 -1800 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.3 2.5 -------------- 1801 -2400 2.0 2.0 2.0 1.5 1.5 1.5 2.0 2.0 2.0 0.0 1.4 2.5 DAILY VALUE 2.0 2.0 2.0 1.5 1.7 2.0 2.0 2.1 2.5 ~'.--------------------------------------------------------------------------------- 4-C-248 fil!lIiiI Table 4-C-73.Cont. 4-C-249 Table 4-C-73.Cont. -MAY 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX 0001 0600 1.5 1.8 2.0 0601 1200 3.0 4.3 5.5 1201 1800 3.5 4.7 5.5 1801 2400 3.0 3.0 3.0 DAILY VALUE 1.5 3.5 5.5 0001 0600 2.5 2.5 2.5 0601 1200 3.5 4.3 5.0 1201 1800 4.0 5.0 6.0 1801 2400 2.5 2.8 3.0 DAILY VALUE 2.5 3.7 6.0 0001 0600 2.0 2.2 2.5 0601 1200 3.0 4.0 4.5 1201 1800 3.5 4.3 5.0 1801 2400 3.0 3.0 3.0 DAILY VALUE 2.0 3.4 5.0 ---- 0001 0600 2.0 2.2 2.5 0601 1200 3.0 4.3 5.0 ---""r 1201 1800 4.0 4.8 5.5 1801 2400 2.5 2.8 3.0 DAILY VALUE 2.0 3.5 5.5 0001 0600 2.0 2.0 2.0 0601 1200 3.5 4.8 6.0 1201 1800 4.0 4.8 5.5 1801 2400 2.5 2.8 3.0 DAILY VALUE 2.0 3 .6 6.0 0001 0600 2.0 2.3 2.5 0601 1200 3.5 5.2 6.5 1201 1800 6.5 6.5 1801 2400 DAILY VALUE 2.0 6.5 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE MONTHLY VALUE 1.5 ---6.5 lI!5ifi', -------------------------------------------------------------------------------- 4-C-250 '~,Table 4-C-74.Thermograph data summary.winter intragravel water temperature (C), Slough 9B,RM 129.0,Geocode S30N03W16ABB. -FEBRUARY 1982 - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN·MEAN MAX DAYS 25 -31 MIN MEAN MAX !"'" 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 "--- DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 4-C-251 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 MONTHLY VALUE 1.0 --,.;,-1.0 Table 4-C-74.Cont. -MARCH 1982 - TIME PERIOD 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE DAYS 1 - 8 MIN MEAN MAX 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1 .0 1 .0 1.0 1.0 1.0 1.0 1.0 1.'0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 DAYS 9 -16 MIN MEAN MAX 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 DAYS 17 -24 MIN MEAN MAX 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.0 1.2 1.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.5 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 DAYS 25 -31 MIN MEAN MAX 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.01.01.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.0 1.1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.8 2.0 1.5 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 ~I 0001 -0600 0601 -1200 1201 -1800 1801 -2400 DAILY VALUE 1.0 1.0 1.0 1.01.0'1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.0 1.1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.0 1.0 1.0 --------------- 1.0 1.0 1.0 MONTHLY VALUE 1.0 1.0 1.0 -----.--------- 1.0 1.0 1.0 1.0 1.3 2.0 1.0 1.0 1.0 - -------------------------------------------------------------------------------- 4-C-252 Table 4-C-74.Cont. -APRIL 1982 - --------------------------------------------------------------------------------......TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN HAX --------------------------------------------------------------------------------,... 0001 -0600 2.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 4.0 4.0 4.0 0601 -1200 2.0 2.0 2.0 2.0 2.0 2.0 2.5 2.7 3.0 3.5 3.7 4.0 1201 -1800 2.0 2.0 2.0 2.0 2.0 2.0 \2.5 2.7 3.0 3.5 3.8 4.0 1801 -2400 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 4.5 4.7 5.0 DAILY VALUE 2.0 2.0 2.0 2.0 2.1 2.5 2.5 2.8 3.0 3.5 4.0 5.0 0001 -0600 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 4.5 4.7 5.0-0601 -1200 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 4.0 4.0 4.0 1201 -1800 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 4.0 4.3 4.5 1801 -2400 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 5.0 5.0 5.0 DAILY VALUE 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 4.0 4.5 5.0 0001 -0600 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.0 3.0 4.5 4.8 5.0 0601 -1200 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.7 3.0 4.0 4.2 4.5 1201 -1800 2.0 2.0 2.0 2.5 2.5 2.5 2.5 2.7 3.0 4.0 4.2 4.5 1801 -2400 2.0 2.0 2.0 2.5 2.8 3.0 3.0 3.0 3.0 5.0 5.0 5.0 DAILY VALUE 2.0 2.0 2.0 2.5 2.6 3.0 2.5 2.8 3.0 4.0 4.5 5.0 ra--_~0001 -0600 2.0 2.0 2.0 2.5 2.8 3.0 2.5 2.8 3.0 5.0 5.0 5.0 0601 -1200 2.0 2.0 2.0 2.0 2.2 2.5 2.5 2.5 2.5 4.0 4.3 4.5 1201 -1800 2.0 2.0 2.0 2.0 2.2 2.5 2.5 2.7 3.0 4.5 4.7 5.0 1801 -2400 2.5 2.5 2.5 2.5 2.8 3.0 3.0 3.0 3.0 5.0 5.3 5.5 DAILY VALUE 2.0 2.1 2.5 2.0 2.5 3.0 2.5 2.7 3.0 4.0 4.8 5.5 0001 -0600 2.5 2.5 2.5 2.5 2.7 3.0 3.0 3.0 3.0 5.0 5.3 5.5 0601 -1200 2.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 4.5 4.5 4.5-1201 -1800 2.0 2.0 2.0 2.0 2.2 2.5 3.0 3.0 3.0 4.5 4.8 5.0 1801 -2400 2.0 2.3 2.5 3.0 3.0 3.0 3.0 3.3 3.5 5.5 5.7 6.0 DAILY VALUE 2.0 2.2 2.5 2.0 2.5 3.0 3.0 3.1 3.5 4.5 5.1 6.0 ~0001 -0600 2.0 2.5 2.5 2.8 3.0 3.5 3.5 5.5 6.02.2 3.5 5.0 0601 -1200 2.0 2.0 2.0 2.5 2.5 2.5 3.0 3.2 3.5 5.0 5.0 5.0 1201 -1800 2.0 2.0 2.0 2.5 2.7 3.0 3.0 3.2 3.5 5.0 5.0 5.0-1801 -2400 2.5 2.5 2.5 3.0 3.0 3.0 3.5 3.8 4.0 5.0 5.3 5.5 DAILY VALUE 2.0 2.2 2.5 2.5 2.7 3.0 3.0 3.4 4.0 5.0 5.2 6.0 0001 -0600 2.0 2.3 2.5 3.0 3.0 3.0 4.0 4.0 4.0 ----------- 0601 -1200 2.0 2.0 2.0 2.5 2.7 3.0 3.5 3.5 3.5 ------------ 1201 -1800 2.0 2.0 2.0 2.5 2.7 3.0 3.5 3.7 4.0 ------------ 1801 -2400 2.0 2.3 2.5 3.0 3.0 3.0 4.0 4.0 4.0 ----------- DAILY VALUE 2.0 2.2 2.5 2.5 2.8 3.0 3.5 3.8 4.0 ----------- I""" 0001 -0600 2.0 2.2 2.5 3.0 3.0 3.0 4.0 4.0 4.0 --------------- 0601 -1200 2.0 2.0 2.0 3.0 3.0 3.0 3.5 3.7 4.0 MONTHLY VALUE 1201 -1800 2.0 2.0 2.0 3.0 3.0 3.0 3.5 3.8 4.0 --------------- 1801 -2400 2.0 2.0 2.0 3.0 3.0 3.0 4.0 4.0 4.0 2.0 3.0 6.0 DAILY VALUE 2.0 2.0 2.5 3.0 3.0 3.0 3.5 3.9 4.0 -------------------------------------------------------------------------------- 4-C-253 Tab le 4-C-74.Cant. -MAY 1982 - - TIME PERIOD DAYS 1 - 8 MIN MEAN MAX DAYS 9 -16 MIN MEAN MAX DAYS 17 -24 MIN MEAN MAX DAYS 25 -31 MIN MEAN MAX -------------------------------------------------------------------------------- 0001 0600 5.0 5.3 5.5 0601 1200 5.0 5.0 5.0 1201 1800 5.0 5.0 5.0 1801 2400 5.5 5.8 6.0 DAILY VALUE 5.0 5.3 6.0 0001 0600 5.5 5.8 6.0 0601 1200 5.0 5.0 5.0 1201 1800 5.0 5.2 5.5 1801 2400 5.5 5.8 6.0 DAILY VALUE 5.0 5.5 6.0 0001 0600 5.5 5.8 6.0 0601 1200 5.0 5.0 5.0 1201 1800 5.0 5.0 5.0 1801 2400 5.0 5.3 5.5 DAILY VALUE 5.0 5.3 6.0 0001 0600 5.0 5.2 5.5 0601 1200 4.5 4.1 5.0 1201 1800 4.5 4.1 5.0 1801 2400 5.0 5.3 5.5 DAILY VALUE 4.5 5.0 5.5 0001 0600 5.0 5.3 5.5 0601 1200 4.5 4.5 4.5 1201 1800 4.5 4.8 5.0 1801 2400 5.0 5.3 5.5 DAILY VALUE 4.5 5.0 5.5 0001 0600 5.0 5.2 5.5 0601 1200 4.5 4.1 5.0 1201 1800 1801 2400 DAILY VALUE 4.5 5.5 0001 0600 0601 1200 1201 1800 1801 2400 DAILY VALUE 0001 0600 ------------- 0601 1200 MONTHLY VALUE 1201 1800 -------------- 1801 2400 4.5 ---6.0 DAILY VALUE -------------------------------------------------------------------------------- 4-C-254 - ~, -4-C-255 -,or;.~Table 4-C-75.Cant. ~ -APRIL 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- 0001 -0600 4.0 4.0 4.0 4.0 4.0 4.0 --- --- --------------- 0601 -1200 4.0 4.0 4.0 4.0 4.0 4.0 ---------------------- 1201 -1800 4.0 4.0 4.0 4.5 4.5 4.5 ---------------------- 1801 -2400 4.0 4.0 4.0 4.0 4.3 4.5 --------------------- DAILY VALUE 4.0 4.0 4.0 4.0 4.2 4.5 ----------------------- 0001 -0600 4.0 4.0 4.0 4.0 4.0 4.0 ---------------------- 0601 -1200 4.0 4.0 4.0 4.0 4.0 4.0 ---------------------- 1201 -1800 4.0 4.0 4.0 4.5 4.8 5.0 ----------------._--- 1801 -2400 4.0 4.0 4.0 4.0 4.3 4.5 ---------------------- DAILY VALUE 4.0 4.0 4.0 4.0 4.3 5.0 ------------------------ 0001 -0600 4.0 4.0 4.0 4.0 4.0 4.0 ----------------------- 0601 -1200 4.0 4.0 4.0 4.0 4.0 4.0 ---------------------- 1201 -1800 4.0 4.0 4.0 4.5 4.8 5.0 -------------------- 1801 -2400 4.0 4.0 4.0 4.5 4.7 5.0 --------------------- DAILY VALUE 4.0 4.0 4.0 4.0 4.4 5.0 --------------------- ~.,,,.,........"'0001 -0600 4.0 4.0 4.0 4.5 4.5 4.5 ----------------------- 0601 -1200 4.0 4.0 4.0 4.5 4.5 4.5 ---------------------- 1201 -1800 4.0 4.0 4.0 4.5 4.8 5.0 ----------------------- 1801 -2400 4.0 4.0 4.0 4.5 4.7 5.0 ----------------------- DAILY VALUE 4.0 4.0 4.0 4.5 4.6 5.0 ----------------------- 0001 -0600 4.0 4.0 4.0 4.0 4.2 4.5 ----------------------- 0601 -1200 4.0 4.0 4.0 -----------------------------._---.-1201 -1800 4.0 4.0 4.0 -------------------------------- 1801 -2400 4.0 4.0 4.0 --------------------------------- DAILY VALUE 4.0 4.0 4.0 4.0 ---4.5 ---------------------- 0001 -0600 4.0 4.0 4.0 --------------------------------- 0601 -1200 4.0 4.0 4.0 --------------------- --- -------- 1201 -1800 4.0 4.0 4.0 ------------------------------ ~1801 -2400 4.0 4.0 4.0 -------------------- ----------- DAILY VALUE 4.0 4.0 4.0 -------------------------------- 0001 -0600 4.0 4.0 4.0 -------------------------------- 0601 -1200 4.0 4.0 4.0 --------------------------------- 1201 -1800 4.0 4.3 4.5 ------------------ --------------- 1801 -2400 4.0 4.3 4.5 ----------------------------------- DAILY VALUE 4.0 4.2 4.5 -------------------------------- 0001 -0600 4.0 4.0 4.0 ----------------------------------- 0601 -1200 4.0 4.0 4.0 ---------------------MONTHLY VALUE 1201 -1800 4.0 4.3 4.5 ------------------------------------ 1801 -2400 4.0 4.2 4.5 ------------------._---4.0 ---5.0 DAlLY VALUE 4.0 4.1 4.5 --------------------- ---- --------------------------------------------------------------------------------- 4-C-257 ~ Tab Ie 4-C-7 6.Thermograph data summary,winter intragravel water temperature (C), Slough 21-Mouth,RM 142.0,Geocode S31NllW02AAA."""".. '"""-FEBRUARY 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 -8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAx -, ------------------------------------------------------------------------------- 0001 -0600 -----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 _. ------------ 1201 -1800 --------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 ----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE ---------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ~ 0001 -0600 -----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 -----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 ------------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 -----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE ------------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 ------- ----3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 ------------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 ------------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 --------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE ----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 ----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 -----------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 -"""':1201 -1800 ---------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 ------------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE ---- ------3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ~ 0001 -0600 ---- --------3.0 3.0 3.0 3.0 3.0 3.0 ----------- 0601 -1200 ------------3.0 3.0 3.0 3.0 3.0 3.0 ------------ 1201 -1800 -----------3.0 3.0 3.0 3.0 3.0 3.0 ---------- 1801 -2400 -----------3.0 3.0 3.0 3.0 3.0 3.0 ------------ DAILY VALUE -----------3.0 3.0 3.0 3.0 3.0 3.0 ------------ 0001 -0600 ---------3.0 3.0 3.0 3.0 3.0 3.0 ------ ---- 0601 1200 3.0 3.0 3.0 3.0 3.0 3.0 f'I"'!l---------------------- 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ----------- 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ---------- DAILY VALUE 3.0 ---3.0 3.0 3.0 3.0 3.0 3.0 3.0 ----------- 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ----------- 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ------------ 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ------------ 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ------------ DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ------------ 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ---------------~ 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 MONTHLY VALUE 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ----------_.-_- 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ~ DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ---------------------------------------------------------------------------------..., 4-C-258 ~ "..,. !.... '-"Table 4-C-76.Cont. f- -MARCH 1982 - -------------------------------------------------------------------------------- TIME DAYS 1 - 8 DAYS 9 -16 DAYS 17 -24 DAYS 25 -31 PERIOD MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX MIN MEAN MAX -------------------------------------------------------------------------------- !"""0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 .....1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 3.0 3.0 3.0 3.0 3.0 .3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ~0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 0001 -0600 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 --------------- 0601 -1200 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 MONTHLY VALUE 1201 -1800 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 ----_._--------.....1801 -2400 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 DAILY VALUE 3.0 3.0 3,.0 3.0 3.0 3.0 3.0 3.0 3.0 -------------------------------------------------------------------------------- 4-C-259 Table 4-C-77.Weekly mln1mUm,mean and maximum winter surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Whiskers Creek Slough,RM 101.2,- GC S26N05W03ADB. --------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)it OF it OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 21 820218 0.0 .9 1.5 25 3-22 820225 0.0 .7 1.0 84 7 23 820304 1.0 1.2 1.5 84 7 24 820311 1.5 1.5 1.5 84 7 25 820318 1.5 1.5 1.5 84 7 26 820325 1.5 1.5 1.5 84 7 27 820401 1.5 1.5 1.5 84 7 28 820408 1.5 1.5 1.5 84 7 29 820415 1.5 1.5 1.5 84 7 30 820422 1.5 1.7 2.0 84 7 31 820429 1.5 1.7 2.0 84 7 32 820506 1.5 1.5 1.5 6 1 -------------------------------------------------------------- - 4-C-261 Table 4-C-78.Weekly minimum,mean and maximum winter surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 9B,RM 129.0,GC S30N03W16ABB. --------------------------------------------~-----------------WATER STARTING WEEKLY VALUE (c)#OF IF OF -YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 22 820225 1.3 1.7 1.8 55 5 23 820304 1.8 1.8 2.3 84 7 24 820311 1.8 1.9 2.3 84 7 ~ 25 820318 1.8 1.8 2.3 84 7 26 820325 ,1.8 2.7 3.8 ,84 .7 27 820401 2.8 3.2 3.8 84 7 _. 28 820408 2.8 3.5 4.8 84 7 29 820415 2.8 4.0 5.3 84 7 30 820422 3.3 5.5 8.3 84 7 -. 31 820429 3.8 6.4 10.3 84 7 32 820506 4.3 5.3 6.8 6 1 --------------------------------------------------------------.-- - 4-C-262 ...... ..... "'.. - Table 4-C"-79.~Jeekly nll nl mum,mean and maximum winter surface water temperature ,(C).obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 9-Below Tributary S,RM 129.0, GC S30N03W16ABC. -----------------------------------------------------------~-- WATER STARTING WEEKLY VALUE (c)#OF 41 OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 19 820204 .2 .2 .2 5 1 20 820211 .2 .2 .2 84 7 21 820218 .2 .7 1.7 84 7 22 820225 .7 1.5 2.2 84 7 23 820304 .7 2.2 3.2 84 7 24 820311 .7 1.5 2.7 80 7 25 820318 1.6 2.6 3.6 84 7 26 820325 .6 1.3 2.6 84 7 27 820401 .6 1.0 2.1 84 7 28 820408 .6 1.5 2.6 84 7 29 820415 1.1 2.1 3.6 84 7 30 820422 1.6 2.9 5.1 84 7 31 820429 2.1 3.6 6.1 84 7 32 820506 2.6 3.9 6.6 6 1 -------------------------------------------------------------- 4-C-263 Table 4-C-80.Weekly mlnlmum,mean and maximum winter surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year w€'ek,Slough 11,RM 135.3.GC S31NO?tH9DDD. -------------------------------------------------------------- WATER STARTING WEEK,LY VALUE (c)#OF 1f OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 21 820218 2.0 2.0 2.0 4 1 22 820225 2.0 2.0 2.5 84 7 23 820304 2.0 2.4 3.0 84 7 24 820311 2.0 2.5 3.0 84 7 25 820318 2.0 2.5 3.0 84 7 26 820325 2.0 2.7 3.5 84 7 27 820401 2.5 2.8 4.0 84 7 28 820408 2.0 3.0 4.0 84 7 29 820415 2.5 3.4 5.5 84 7 30 820422 3.0 4.1 5.0 9 1 4-C'-264 - - .- - Table 4..C-Bl.Weekly mlnlmUm,mean and maximum winter surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week~Slough 19~RM 140.0,GC S31N11W10DBB. -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)/}OF if OF YEAR CALENDAR -------------------2-HOURLY DAYS IN-WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 19 820204 1.8 2.1 2.3 41 4 20 820211 2.3 2.3 2.3 84 7 21 820218 2.3 2.3 2.3 84 7 22 820225 .8 1.5 2.3 84 7 ..-23 820304 .8 2.1 2.3 84 7 24 820311 2.3 2.3 2.3 84 7 25 820318 2.3 2.3 2.3 84 7-26 820325 2.3 2.3 2.3 84 7 27 820401 2.3 2.3 2.3 84 7 28 820408 2.3 2.3 2.3 84 7 29 820415 2.3 2.3 2.3 84 7 ~,-~"'-30 820422 2.3 2.3 2.8 84 7 31 820429 2.3 2.8 4.3 84 7 32 820506 2.3 2.3 2.3 3 1 ,~ -------------------------------------------------------------- ,~ ...... - 4-C-265 Table 4-C-82.Weekly mlnlmUm,mean and maximum winter surface water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 21-Mouth,RM 142.0,GC S31NllW02AAA. 4-C-266 ..." ~I r Table 4-C-83.Week"ly mlnlmum,mean and max"irnum winter'surface water temperature (C)obtained fl"om 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 21-Middle,RM 142.0,GC S31N11W02AAA. -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)41 OF 41 OF YEAR CALENDAR -------------------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD ~'JlRlt. ----------------------------------------------------~--------- 23 820304 .5 .8 1.0 29 3 24 820311 .5 .8 1.5 84 7 25 820318 1.0 1.3 2.0 84 7 26 820325 .5 1.0 2.0 84 7 27 820401 .5 1.1 2.5 84 7 28 820408 1.0 1.5 3.0 84 7 29 820415 .5 2.2 5.0 84 7 30 820422 1.5 2.8 5.0 84 7 31 820429 1.0 2.6 5.0 52 5 -------------------------------------------------------------- 4-C-267 Table 4-C-84.Weekly mlnlmum,mean and maximum winter intragravel water temperature (C)obtained from 2-hour Ryan thermograph readings and 1i sted by USGS water year week,Slough 9-Below Tributary B, RM 129.0~GC S30N03W16ABC. WATER YEAR WEEK STARTING CALENDAR DATE WEEKLY VALUE (c) MIN MEAN MAX 41 OF 2-HOURLY READINGS 41 OF DAYS IN RECORD 19 820204 .5 .6 1.0 16 2 20 820211 0.0 .2 1.0 84.7 21 820218 .5 .7 1.0 84 7 22 820225 1.0 1.1 1.5 84 7 23 820304 .5 1.8 2.0 84 7 24 820311 .5 1.2 2.0 84 7 25 820318 1.5 2.0 2.5 84 7 26 820325 0.0 .8 2.0 84 7 27 820401 0.0 .6 2.0 84 7 28 820408 .5 1.2 2.0 84 7 29 820415 .5 1.6 3.0 84 7 30 820422 1.0 2.4 4.5 84 7 31 820429 1.5 3.4 6.0 84 7 32 820506 2.0 4.1 6.5 7 1 4-C-268 - -. Table 4-C-85.Weekly mlnlmum,mean and maximum winter intragravel water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slnugh 98,RM 129.0, GC S30N03W16ABB. I"""-------------------------------------------------------------- WATER STARTING WEEKLY VALUE (c)iF OF 1F OF YEAR CALENDAR -------------------Z-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD 1"'''-------------------------------------------------------------- 22 820225 1.0 1.0 1.0 52 5 23 820304 1.0 1.2 1.5 84 7 24 820311 1.5 1.5 1.5 84 7 25 820318 1.0 1.0 1.5 84 7 26 820325 1.0 1.5 2.0 84 7 27 820401 2.0 2.1 2.5 84 7 28 820408 2.0 2.4 3.0 84 7 29 820415 2.5 2.9 3.5 84 7.....30 820422 3.0 4.1 5.5 84 7 31 820429 4.5 5.2 6.0 84 7 32 820506 4.5 4.9 5.5 6 1 ~,~ ..... - -4-C-269 Table 4-C-86.Weekly mlnlmum,mean and maximum winter i ntragravel water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 19,RM 140.0, GC S31N11W100BB. ~, -------------------------------------------------------------- WATER STARTING WEEKLY VALUE (C)if OF ft OF YEAR CALENDAR -~----------~------2-HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD ---------------------~---------------------------------------- 19 820204 4.0 4.0 4.0 64 6 20 820211 4.0 4.0 4.0 84 7 21 820218 4.0 4.0 4.0 84 7 22 820225 4.0 4.0 4.0 84 7 23 820304 4.0 4.0 4.0 84 7 24 820311 4.0 4.0 4.0 84 7 25 820318 4.0 4.1 4.5 84 7 26 820325 4.0 4.1 4.5 84 7 27 820401 4.0 4.0 4.5 84 7 28 820408 4.0 4.3 5.0 63 6 -------------------------------------~------------------------ 4-C-270 ~; ! - ..... Tab 1e 4~C-87.Weekly minimum,mean and maximum winter intragravel water temperature (C)obtained from 2-hour Ryan thermograph readings and listed by USGS water year week,Slough 21-Mouth,RM 142.0, GC S31NIHJ02AAA. .....-------------------------------------------------------------- ,WATER STARTING WEEKLY VALUE (c)4/OF 4/OF YEAR CALENDAR -------------------2..,.HOURLY DAYS IN WEEK DATE MIN MEAN MAX READINGS RECORD -------------------------------------------------------------- 19 820204 3.0 3.0 3.0 53 5 20 820211 3.0 3.0 3.0 84 7 21 820218 3.0 3.0 3.0 84 7 22 820225 3.0 3.0 3.0 84 7 23 820304 3.0 3.0 3.0 84 7 24 820311 3.0 3.0 3.0 84 7 25 820318 3.0 3.0 3.0 84 7 26 820325 3.0 3.0 3.0 84 7 27 820401 3.0 3.0 3.0 84 7 28 820408 3.0 3.0 3.0 84 7 29 820415 3.0 3.0 3.0 84 7 ~$,_.~30 820422 3.0 3.0 3.0 36 3I -------------------------------------------------------------- P"" 4-C-271 Appendix Table 4-C-88.Instantaneous intragravel water temperatures obtained ~ at salmon spawning redds in Slough 8A~Susitna River,-Alaska,1982.- Time (hours)Redd Salmon Intragravel a Surfaceb ~ Date Begin End No.Species Temp (0C)Temp (OC) August 26~1982 1830 1920 03 Chum 11.4 12.6 02 Chum 11.2 13.0 04 Chum -.-13.2 15 Chum -.-13.2 14 Chum -.-13.2 ~ 13 Chum -.-12.8 11 Chum -.-13.2 09 Chum ·13.2 08 Chum ·13.2 07 Chum -.-13.2 06 Chum -.-13.1 05 Chum -.-13.0 10 Chum ·13.2 01 Chum -.-13.0 12 Chum ·13.0 1945 2039 01 Pink -.-13.0 22 Chum -.-12.4 21 Chum -.-12.4 ~-16 Chum -.-12.4 18 Chum -.-12.4 17 Chum -.-12.0 19 Chum -.-12.4 24 Chum -.-12.0 25 Chum ·12.0 26 Chum -.-11.5 -27 Chum -.-1l.0 September 6,1982 1540 1910 40 Chum -.-7.6 41 Chum 5.1 7.6 42 Chum 6.7 7.6 43 Chum 4.9 7.6 44 Chum 6.1 7.6 45 Chum ·7.6 46 Chum 4.9 7.6 47 Chum 5.7 7.6 48 Chum 6.9 7.6 """49 Chum 5.2 7.6 01 Sockeye 7.4 7.6 50 Chum ·7.6 aApproximately 6 inches beneath streambed. bJust below surface to mid-column. 4-C-272 """ .... Appendix Table 4-C-89 (Continued)~: ~), -,. Time (hours)Intragravel a Surface b , Redd Salmon i Date Begin End No.Species Temp (Oe)Temp (OC) ~- September 5,1982 1344 1910 36 Chum 4.6 8.4 I 37 Chum 5.5 8.8 38 Churn 4.2 8.8 ~39 Chum --9.0 ,·! 40 Chum -·-9.0 41 Chum -·-8.8 42 Chum -·-8.6 -~ 43 Chum -·-8.6 44 Chum -·-7.0 September 6,1982 1040 1200 45 Chum -·-6.6 ~ ,~- aApproximately5 inches beneath streambed. bJust below surface to mid':'column. 4-C-274 - - Appendix Table 4-C-90.Instantaneous intragravel water temperatures obtained at salmon spawning redds in Slough 11,Susitna River~ Al aska,1982. Time (hours)Redd Salmon Intragrave 1a Surface b Date Begin End No.Species Temp (DC)Temp (OC) September 6,1982 N/A N/A Chum 5.0 7.1 Chum 6.1 7.0 Chum .7.0 ~Chum 4.3 6.8 Chum 4.3 6.8 Sockeye 5.3 6.8 Chum 4.1 7.0 September 20,1982 1030 1745 01 Sockeye 3.1 ·02 Sockeye 4.1 -.- 03 Sockeye 3.2 ·04 Sockeye 3.4 ·05 Sockeye 3.1 ·06 Sockeye 3.2 · F 07 Sockeye 3.2 -·- 01 Chum 4.6 ·02 Chum 4.3 · ~~~.03 Chum 4.9 ·08 Sockeye 4.0 ·04 Sockeye 4.5 ·05 Sockeye 4.4 ·06 Sockeye 5.0 ·09 Sockeye 4.2 ·08 Chum 5.5 ·10 Sockeye 3.0 ·11 Sockeye 3.1 -.- 12 Sockeye 3.0 ·13 Sockeye 3.6 ·14 Sockeye 3.5 ·15 Sockeye 3.1 ·16 Sockeye 3.2 ·~17 Sockeye 3.2 ·18 Sockeye 3.2 -.- 09 Chum 3.1 ·19 Sockeye 3.4 ·20 Sockeye 3.4 ·21 Sockeye 3.0 ·22 Sockeye 3.2 -.- ,..., aApproximately 6 inches beneath streambed. bJust below surface to mid-column. 4-C-275 Appendix Table 4-C-91.Instantaneous intragravel water temperatures obtained at salmon spawning redds in Slough 21,Susitna River, Alaska,1982. Time (hours)Redd Salmon Intragravel a Surfaceb -Date Begin End No.Species Temp (OC)Temp (OC): September 3,1982 1720 N/A 01 Chum 5.5 6.6 02 Chum 4.9 6.3 03 Chum 4.7 6.3 04 Chum 4.5 5.1 05 Chum 5.0 5.5 September 4,1982 1413 1600 06 Chum 4.7 7.4 07 Chum 4.8 7.2 08 Sockeye 4.8 7.5 09 Chum 4.7 7.5 10 Chum 4.9 7.4 11 Chum 5.6 7.2 12 Chum 5.5 7.4 ~ 13 Chum 5.5 7.2 14 Chum 4.6 7.3 15 Chum 4.7 7.3 ""'l16Chum4.6 7.6 1 17 Chum 4.8 7.4 18 Chum 4.5 7.3 19 Chum 4.7 7.3 -20 Chum 5.2 7.4 21 Chum 4.3 7.3 22 Chum 4.6 7.3 23 Chum 4.2 7.5 24 Chum 4.6 7.4 25 Chum 4.7 7.5 26 Chum 4.6 7.4 27 Chum 4.9 7.3 28 Chum 4.2 7.3 29 Chum 4.4 7.5 ~ 30 Chum 4.0 7.5 31 Chum 4.4 7.5 32 Chum 4.4 7.6 -33 Chum 4.7 7.6 34 Chum 4.8 8.7 aApproximately 6 inches beneath streambed. bJust below surface to mid-column. - 4-C-276