Loading...
HomeMy WebLinkAboutSusitna Hydro Aquatic Studies Vol 5 1982PREFACE TI<.. I~d S" I sa A /·8;',(." no·5"~od 1Refer to This report is part of a five volume presentation of the fisheries, aquatic habitat,and instream flow data collected by the Alaska Depart- ment of Fish and Game (ADF&G)Susitna Hydroelectric (Su Hydro) Feasibility Aquatic Studies Program during the 1981-82 (October-May) ice-covered and 1982 open water (May-October)seasons.It is one of a series of reports prepared for the Alaska Power Authority (APA)and its principal contractor,Acres American (Acres)by the ADF&G and other contractors to evaluate the feasibility of the proposed Susitna Hydroelectric Project.This preliminary draft is an internal working document and intended for data transmittal to other Susitna Hydro- electric Feasibility Study participants.A final report will be c1.is- tributed April 15,1983. The topics discussed in Volumes Two through Five are illustrated in Figure A.Volume One (to be distributed with the final report)will present a synopsis of the information contained in the other four volumes.Volume Two also includes a comparison of 1981 and 1982 adult anadromous fisheries data. A second.ADF&G report will include an analysis of the pre-project fishery and habitat relationships derived from this and related reports prepared by other study partidpppts.A review draft will be circulated to study participants on May 1,1983.The final report will be subr]itted to the AP A on June 30,1983 for formal distribution to study partici- pants,state and federal agencies,and the public.Scheduled for completion on the same date is the first draft of the ADF&G 1982-83 ice covered season basic data report.It will include a presentation of 1982-83 incubation and other fishery and habitat data. ARLIS Alaska Resources Library &Information Services Aulch0rage.AJaska Volume One for References. I 33755000352559rFactorsInfluencingAquaticHabitatFishLifePhasesInfIuencedbyHabitatt-\Rive,MorphologyVol.4.Vol.5IIcondlllon.~...•..__::t::'~"~(jlj~-Phy.icolVol.4,Vol.5ChemicalVol.4,Vol.5aFoodHabl"----Val.3~OUlmlgrallan~Vol.3SpawningVal.3,Vol.5RearingVol.3,Val.4,Val.5DlllribullanVal.3,Vol.4,Vol.5FiCJUrcJ~ProgramelementspresentedinVolumesTwothroughFive. These and other ADF&G reports (1974-1976,1977, 1978, 1979,1981a,b, c,d,e,f,1982 1 )and information reported by others will be summarized and analyzed by the Arctic Environmental Information and Data Center (AEIDC)to evaluate post-project conditions.Woodward Clyde Consultants will,in turn,use this information to support their preparation of the Federal Energy Regulatory Commission License Appli- cation for Acres. The five year (Acres 1980 1 )ADF&G Su Hydro Aquatic Studies program was initiated in November,1980.It is subGivided into three study sections:Adult Anadromous Fish Studies (AA),Resident and Juvenile Anadromous Fish Studies (RJ),and Aquatic Habitat and Instream Flow Studies (AlI). Specific objectives of the three sections are: 1.AA -determine the seasonal distribution and relative abun- dance of adult anadromous fish populations produced within the study area (Figure B); 2.RJ -determine the seasonal distribution and relative abun- dance of selected resident and juvenile anadromous fish populations within the study area;and 3.AH characterize the seasonal br,bitat requirements of selected anadromous and resident fish species within the study area and the relationship between the availability of these habitat conditions and the mainstem discharge of the Susitna River. The 1982 ADF&G portion (Figures C and D)of the overall feasibility project study area (Figure B)was limited to the mainstem Susitna River and the mouths of major tributaries.Portions of tributaries which will 1Refer to Volume One for References. III ARLIS Alaska Resources Library &Information SerVices I\nchvrage,lUdska o25II•ADF6GFIELDCAMPS---DRAINAGEBOUNDARY,"'........................,"\\\,IIII,Ia/I.;.;~AnchorageCookInletIIIIIt\,,,,,,,(TRM40),,",milesa""..()IDD~.Qt?~Fi(jure!".SusitnaRiverdr~inagebasin. ~1982OPENWATERSEASONSTUDYAREA--DRAINAGEBOUNDARY"""..............................."'-,\\,,II,,,.I~,I"'....----,,/"--_.......//,,/,,"/"IIII,,',,"",/II//,,/...-"o25IImiles..,••••11(:1\~Figurec.1982ADF&Goppnwaterseason(MaythroughOctober)studyarea. 1981-82ICECOVEREDSEASONSTUDYAREADRAINAGEBOUNDARY~oo\",","'"o26,IImiles-.·0•.,....,'I/~,I-'"1II,1'......",'"............",............/............,\,\I,II/I//I",/,--~-~~,~I,,~J//",-..........'",......_---11Fiqurc::I1981--8?I\DF&GicecO'Jrreciseason(Octoberthroll(jh~lav)studyarea. be inundated by the proposed impoundments were also evaluated. Descriptions of study sites are presented in each of these volumes including the ADF&G reports (ADF&G 1981a,b,c,d.e.f1). The Susitna River is approximately 275 miles long from its sources in the Alaska Mountain Range to its point of discharge into Cook Inlet. Its drainage encompasses an area of 19.400 square miles.The mainstem and major tributaries of the Susitna River.including the Chulitna, Talkeetna and Yentna rivers.originate in glaciers and carry a heavy load of glacial flour during the ice-free months (approximately May through October).There are many smaller tributaries which are perenially clear. Questions concerning these reports should be directed to: Thomas W.Trent Aquatic Studies Coordinator Alaska Department of Fish 8i Game Su Hydro Aquatic Studies Program 2207 Spenard Road Anchorage,Alaska 99503 Telephone (907)274-7583 VII DRAFT FIVE/TABLE OF CONTENTS TABLE OF CONTENTS PREFACE.. . . . •••••. . . . . . . . . . . .••. . . . . . . . . ••. •. . . . •. . . . •. •. . . . . . . . . . .I L1ST OF FIGURES....................................................XI LIST OF TABLES •••.••..•..••••...••.•••.•.••••...•..•.••..••..•.••••n LIST OF PLATES ..•..•..•..••••••••..••.•••.•••..••..••.....•••.•••...~ LIST OF APPENDIX B FIGURES ..xsmr LIST OF APPENDIX C TABLES .m- LIST OF APPENDIX D FIGURES XXII CO~'TR I BUTORS •.............•..••.....•.....•.••......•.........•.•..~!._. ACKNO\~LEDGEMENTS...•••••....••.••••....••••....••.•••••...••••••....~ 1.OBJECTIVES ...•••••.•....••••..••..••••••........•...••••.••.•.1 r~ 1.1 Aquatic Habitat Investigations ••••...••••••..•••..••••..•C!/}------- 1.2 Resident Fisheries Investigations •••..•.....•••...•..••.•~- 2.METHODS.. . ••. •. •. •. . . ••. ••. . ••••••. ••. •••. . ••. •. •••. . . ••. . . •••g 2.1 General Study Design -g 2.2 Aquatic Habitat Investigations ....•...'•.•••...••.•.••.../1})----.'_' 2.3 Resident Fisheries Investigations •........•...•.........•'i~ 3•RESULTS .•••..••.••..•.••.•.......•...•...••....•..•.........••;tc 3.1 Tributary Habitat and Fisheries tnvestigations ...••.•....;tc 3.1.1 ,ll,quatic Habitat Investigations .....•....•....••...Z c:' 3.1.1.1 General Stream Descriptions •....•...••...:z..o 3.1.1.2 Water Qua 1 ity i.ji./ 3.1.1.2.1 Instantaneous ~!ater Quality .••L./Lj. 3.1.1.2.2 Continuous Surface ~later Temperature ::-/ 3.1.1.3 Discharge -~ 3.1.2 Resident Fisheries Investigations .•..........•....59 3.1.2.1 Arct i c grayl i ng 5'1 3.1.2.2 Dolly Varden qo 3.2 Mainstem Habitat and Fisheries Investigations •......•.••.qo DRAFT FIVE/TABLE OF CONTENTS 3.2.1 Aquatic Habitat Investigations....................qD 3.2.1.1 General Description of Mainstem Study Area...............................qA 3.2.1.2 Water Quality.............••...•.....•..•Cf1.. 3•2•1•3 Dis cha rg e . . . . . . . . . . . . . . . . . . . . . . . . • . . . • •..Cf .:j 3.2.1.4 Slough Habitats .•......•.••...•.•........q~ 3.2.2 Resident Fisheries Investigations .............•...Glee 3.2.2.1 Burbot ........•.•...•....................'10 3.2.2.2 Longnose Sucker ...............••......•..jO'1 3.2.2.3 Other Species ......•••...................108 3.3 Lake Habitat and Fisheries Investigations 108 3.3.1 Aquatic Habitat Investigations ....•....•..........108 3.3.1.1 General Description of Sally Lake 10~ 3.3.1.2 Water Quality .......•....................//1;" 3.3.2 Resident Fisheries Investigations ......•........../11' 3.3.2.1 Lake Trout ..........................•....//-' 3.3.2.2 Arctic grayl ing .....................•....II~ 4.DISCUSSION •••••••••••••••••••••••••••••••••••••••••••••••••••~) 4.1 Tributary Habitat and Fisheries Investigations ....•......!1'7 4.1.1 Water Quality /"1 4.1.1.1 Instantaneous ~Iater Quality ...........••./11 4.1.1.2 Continuous Surface Water Temperature ...../IS 4. 1•2 Dis cha rg e.. . . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . ...!\9 4.1.3 Stream Gradient Il.l 4.1.4 Barriers to Fish Migration 1~1 4.1.5 Salmon Spa"'/ni ng Habi tat .................•.........I~ 4.1.6 Arctic Grayling Population Estimates 1J.f 4.1.7 Arctic Grayling Spawning and Juven"iles 143 4.1.8 Arctic Grayling Migration .•............•...•......1~4 ~-_.~--::::;~ 4.2 Mainstem Habitat and Fisheries Investigations {//'1[;;·' \, 4.2.1 Water Qual ity '/~_f;,. 4.2.2 Slough Habitats /~> 4.2.3 Resident Fish Species /~~ 4.3 Lake Habitat and Fisheries Investigations •.........•....o !~'1 4.3.1 Resident Fish Species /'-/9 5.LITERATURE CITED ..................•....................•.....•./)1 \ DRAFT FIVE/TABLE OF CONTENTS 6.APPENDICES S"-/1·-1 Appendix A Appendix B Appendix C Appendix D 5,·A~I ~--q .I ~-..c - , 5-D -.f VOLV/TABLES/PAGE 1 08028/Gene TABL5/List of Figures L1ST OF FIGURES Figure 5-1-1 Proposed impoundment study area,1982............~ Figure 5-3-1 Gradient profile of the proposed impoundment reach of the Susitna River and major tributaries ~3 J:1( ,.~ Figure 5-3-3 Figure 5-3-2 ~!lean (e),range (I)and median (-) instantaneous surface water teMpera- tures recorded at selected habitat evaluation sites within the proposed impoundment areas during the 1982 open water field season (n =the number of observations)~-~ t~ean (e),range (I)and median (-) dissolved oxygen concentrations recorded at selected habitat evaluation sites within the proposed impoundment areas during the 1982 open water field season (n =the number of 0 bse rv at ion s). Figure 5-3-4 Mean (e),ranqe (I)and median (-) dissolved oxygen saturation values recorded at selected habitat evaluation sites within the proposed impoundment areas during the 1982 open water field()41seasonn=the number of observations / Figure 5-3-5 Figure 5-3-6 r1ean (e),range (I)and medi an (-) pH values recorded at selected habitat evaluation sites within the prooosed impoundment areas durinq the 198~ open water field seasrn-(n =the number of observations)1..t.4c/ ~1ean (e),ranqe (I)and medi an (-) specific conductance values recorded at selected habitat evaluation sites within the proposed impoundme~t areas during the 198~aDen water field season (n =the number o~observations)·41 Figure 5-3-7 ~1ean (e),range (I)and median (-) turbidity values recorded at selected habitat evaluation sites within the proposed impoundment areas ~uring the 1982 open water field season (n =the number of observati ons)';'(:':' ~~ VOLV/TABLES/PAGE 2 08028/Gene TABL5/List of Figures Figure 5-3-8 Monthly thermograph data summary, mean (e),range (I)and 25th,50th (median),and 75th percentiles (it), for selected habitat evaluation sites within the proposed impoundment areas from June through October, 1982 (n =:he number of two hour interval observations taken each 5 3lTlonthateachsite). Figure 5-3-9 Daily thermograph data summary for Tsusena Creek,RM 181.3,GC S32N04E36ADB, June 20 through October 15,1982 •........•........5'-1 Figure 5-3-10 Daily therlTlograph data summary for ~~atana Creek,Rt1194.1,GC S32N06E25CCA, June 21 throuah August 14,September 9 through September 18 and September 28 through October 15,1982 S-~- Figure 5-3-11 Daily thermograph data summary for Kosina Creek,RM 206.8,GC S31N08EI5BAB, June 28 through Auoust 17 and September 20~-GthroughOctober15,1982 ~. Figure 5-3-12 Daily thermograph data summary for Goose Creek,RM 231.3,GC S30NIIE320BC, June 28 through October 15,1982 S7 Figure 5-3-13 Daily thermograph data summary for the Oshetna River RM 233.4,GC 30NIIE34CCD, ,June 28 through July 1 and <July 9 through c-Q September 26,1982 -J ,-' Figure 5-3-14 Arctic graYling hork and line CPUE for the mouths of the eight tributarY habitat evaluation locations,Proposed f 4 Impoundment Areas,1982 ~ Figure 5-3-15 Arctic grayling hook and line CPUE for the eiaht tribut~rv habitat locations in thpir entiretv, Proposed Impoundment Areas,1982 tv!J- Figure 5-3-16 Arctic grayling age frequency composition,ProDosed Impoundment Areas,1982 'C,l VOLV/TABLES/PAGE 3 08028/Gene TABL5/List of Figures Figure 5-3-17 Arctic grayling length frequency composition for all tributaries combined,Proposed Impoundment Areas 1982 ~.<=t Figure 5-3-18 Arctic grayling length frequency composition by tributary,Proposp.d Impoundment Areas,1982 10 Figure 5 3 19 Arctic grayling age-length relation- ship for all tributaries combined, Proposed Impoundment Areas,1982 '1 J.. Figure 5-3-20 Arctic grayling age-length distribu- tion,Proposed Impoundment Areas,1982 73 Figure 5-3-21 Arctic grayling age-length relation- ship,male vs.females,Proposed Impourdment Areas,1982 '74 Figure 5-3-22 Figure 5-3-23 Figure 5-3-24 Fiqure 5-3-25 Figure 5-3-26 Figure 5-3-27 Arctic grayling sex composition by month,Proposed Impoundment Areas,1982 . Arctic grayling length vs.sexual maturity relationship by sex, Proposed Impoundment Areas,1982 . Arctic grayling instantaneous survival rate curves,Proposed Impoundment Areas,1982 . Susitna River hvdrograph at Vee Canyon, R~223.3 (USGS gaging station No.15291500), from nay 1 through Sertember 30,1982 (USGS,1982). Burbot age frequency composition, Proposed Impoundment Areas,1982.................'1& Burbot lenqth frequency composition, Proposed Imooundment Areas,1982 tt~ Fiqure 5-3-28 Burbot age-length relationship, Proposed Impcundment Areas,1982. ( =mean,-ranqe)ro/ Figure 5-3-29 Burbot age-length relationship, malps vs.females Proposed Impoundment Areas,1982 't")i --,,,,,,- VOLV/TABLES/PAGE 4 08028/Gene TABL5/List of Figures Paqe-'- Figure 5-3-30 Longnose sucker length frequency composition,Proposed Impoundment Areas,1982......................................10/':' Figure 5-3-31 Sally Lake,morphometric map, GCS32N07E29.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . ....t il Figure 5-3-32 Hypsographic (depth-area)curve of Sally Lake,GC S32N07E29,(August,1982)\\~ Figure 5-3-33 Depth-volume curve of Sally Lake, GC S32N07E29 (August,1982)113 VOLV/TARLES/PAGE1 080208/Gene TABL5/List of Tables LIST OF TABLES Table 5-3-1 Table 5-3-2 Table 5-3-3 Table 5-3-4 Topographic features of selected tributaries of the proposed Devil Canyon impoundment,1982 ...........•.............~I Topographic features of selected tributaries of the proposed Watana impoundment,1982 .......•.................z,J.. Discharge data for selected tributaries within the proposed impoundment study area,1982 I~O Arctic grayling hook and line catch by location and month,Proposed Imroundment Areas,1982 ;_1 Table 5-3-5 Arctic grayling hook and line catch and effort by tributary and month for the mouths of the eight tributary habitat evaluation locations,Proposed Impoundment Areas,1982 . Table 5-3-6 Arctic grayling hook and line catch and effort by tributnry and month for the eight tributary habitat evaluation locations in their entirety. Proposed Impoundment Areas,1982 '.:(~'::'~ Table 5-3-7 Arctic grayling aae-length composition, Proposed Impoundment Areas,1982 l,~ Table 5-3-8 Arctic graylir.g length frequency by tributary,Proposed Impound~ent Areas,1982 ~;8 TAble 5-3-9 Arctic grayling tagged by location and month,Proposed Impoundment Areas,1982 •.........'7i Table 5-3-10 Arctic grayling intrastream movement by tributarv and mcnth as demonstrated by recoveries of 1982 tagqpri fish, Proposed Imprundment Areas,1982 ~I Table 5-3-11 Arctic orayling interstream movement by location as demonstrated by recoveries of 1982 taqged fish,Proposed Imp0unriment Areas,1982 i~ Table 5-3-12 VOLV/TABLES/PAGE2 080208/Gene TABL5/List of Tables Arctic grayling interstream movement by location as demonstrated by recoveries of 1981 tagged fish during 1982,Proposed Impoundment Areas,1982 . Table 5-3-17 Table 5-3-13 Arctic grayling population estimates by tributary habitat evaluation location,Proposed Impoundment Areas,1982 ,?~ Table 5-3-14 Data used for Arctic grayling i~~~~~~~~~t~Si~~:~:si9~~~posed 'Z~ Table 5-3-15 Arctic grayling population estimates by age class,Proposed Impoundment Areas,1982 ~1 Table 5-3-16 Burbot catch and catch per trot line day by mainstem site and month, °7,Proposed Impoundment Areas,1982.................-J Burbot age,length and sex frequency, Proposed Impoundment Areas,1982 i OC Table 5-3-18 Table 5-3-19 Table 5-3-20 Trtble 5-4-1 Table 5-4-2 Burbot tagged by mainstem site and month,Proposed Impoundment Areas,1982..........\03 Longnose sucker catches by mainstem site and month,Proposed Impoundment A 1982 105'reas,_. Sally Lake morphometric data,1982 110 Biases,corrections,ar.d assumptions which effect the 1982 Arctic grayling population estimates,Proposed Impoundment Areas,1982 j~1 Arctic 9rcyling population estimates, 1981 versus 1982,Proposerl Impoundment Areas,1982 1'-1:1.. LIST OF PLATES Plate 5-2-1 Plate 5-2-2 Plate 5-3-1 Plate 5-3-2 Plate 5-3-3 Plate 5-3-4 Plate 5-3-5 ------_.•_--'--,,, VOLV/TABLES/PAGE4 080208/Gene TABL5/List of Tables Plane table techniques used for mappi ng of Sally Lake............................/if Arctic grayling implanted with Floy anchor tag 17 Typical substrate found in Tsusena and Kosina Creeks 31 A typical,large,deep pool located below the Proposed Impoundment .'18 Elevation (PIE)in Kosina Creek ,~ Typical habitat of the Oshetna River, lrnq riffle ar'eas with mooprate stream flow ve1ocities 43 Male and female resident Dolly Varden found in Devil Creek ~I Aerial view of Sally Lake II~ VOLV/FIGURES/PAGE1 830209/Gene TA8L5/Appendix 8 Figurf APPENDIX 58 LIST OF FIGURES Fi qure 5-B-1 Proposed Devil Canyon impoundment area of Cheechako Creek,RM 152.4, and adjacent Sus itna Ri ver.......................5··B -.L Figure 5-B-2 Proposed Devil Canyon impoundment area of Chinook Creek,RM 157.0, and adjacent Susitna River S·B·~ Figure 5-B-3 Proposed Devil Canyon impoundment area of Devil Creek,RM 161.4, and adjacent Susitna River 5-i)-3 Figure 5-8-4 Proposed Devil Canyon impoundment area of Fog Creek,RM 176.7,and adjacent Susitna River S-._p,-+ Figure 5-8-5 Proposed Devil Canyon impoundment area of Tsusena Creek,RM 181.3, and adjacent Susitna River ........•..............5-8-5 Figure 5-B-6 Proposed Watana impoundment area of Deadman Creek,RM 186.7, and adjacent Susitna River 5-R-~ Figure 5-8-7 Proposed Watana impoundment area of Watana Creek,RM 194.1,and adjacent Susitna River 5 -(~"l Figure 5-8-8 Proposed Watana impoundment area of Kosina Creek,RM 206.8 and~. t S .t R.'.-)--!)f:-aC,l acen us I na 1 ver . Figure 5-8-9 Proposed Watana impoundment area nf Jay Creek,RM 208.5,and adjacent Susitna River ),8'" Fiqure 5-8-10 Proposed Watana impoundment area of Goose Crpek,RM 231.:,and ~.S'R'1.;.-i~-Iea\.:Jacent us 1 tna ,1 ver-..". Figure 5-8-11 Proposed Watana impoundment area of the Oshetna River,RM 233.4, and adjacent Susitna River ;B-I1 VOLV/FIGURES/PAGE3 830209/Gene TABL5/Appendix B Figur' APPENDIX 5C LIST OF TABLES Table 5-C-l Table 5-C-2 Table 5-C-3 Table 5-C-4 Table 5-C-5 Table 5-C-6 Table 5-C-7 Table 5-C-8 Selected tributary water quality data collected immediately above the mouth of Cheechako Creek, Rr·1 152.4,GC S32NOl E33CCB,1982.....................S-c.-f Selected tributary water quality data collected immediately above the mouth of Devil Creek,RM 161.4,GC S32N02E34AAC,1982 $-t'·1 Selected tributary water quality data collected immediately above the mouth of Fog Creek,RM 176.7, GC S31N04E16DBR,1982 S'C:~ Selected tributary water quality data collected immediately above the mouth of Tsusena Creek,Rr~•'1 -(.-A.181.3,GC S32N04EADR,1982 '~· Selected tributary water quality data collected immediately above the mouth of Deadman Creek,RM 5·-(-3186.7,GC S32N05E26CDB,1982 . Selected tributary water quality data collected one mile above the PIE of Deadman Creek,TRM 3.7, GC S32N05E138BB,1982 5",C-3 Selected tributary water Quality data collected immediately above the mouth of Watana Creek,RM 194.1,GC S32N06E25CCA,1982 •............•..........S-C·q Selected tributary water auality data collected within the two nile study section of Watana Creek, F,'1 5.0,GC 532'1('7E17B,I:;D,1982 ~)<.<c Table 5-C-9 Selected tributary water quality data collected in the East Fork Watana Creek,TRM 9.2 GC S33N07E34CCA,1982 5-L ~ Tab1e 5-C-10 Selected tributary water quality data collected in the \·Ipst Fork vJatana Creek,TRM 9.6 GC S33N07E34CCA,1982 ~~-1 TabsC/rapup Table 5-C-11 Selected tributary water quality data collected immediately above the mouth of Kosina Creek,RM 206.8, GC S31 N08E15BAB,1982 5-C -'1 Table 5-C-12 Selected tributary water quality data collected one mile above the PIE on Kosina Creek,TRM 5.5 GC S30N08E04CDB,1982 S-c.:-8 Table 5-C-13 Selected tributary water quality data collected immediately above the mouth of Jay Creek,RM 208.5, GC S31N08E13BCC,1982 S-C-8 Table 5-C-14 Selected tributary water quality data collected immediately above the mouth of Goose Creek,RM 231.3,. 32 102 S-C9GCS30NllE_nBC,.J8 '- . Table 5-C-15 Selected tributary water quality data collected one mile above the PIE on Goose Creek,TRM 2.2 GC S29Nll E07CCA,1982 ~--C-Cf Table 5-C-16 Selected tributary water quality data collected immediately above the mouth of the Oshetna River,RM 233.4,GC S30Nl134CCD,1982 ·E-c:-IC Table 5-C-17 Selected tributary water quality data collected one mile above the PIE on the Oshetna River TRM 3.2, GC S29Nll E16~.CC,1982 ,,<-10 Table 5-C-18 Selected mainstem water ouality data collected immediately above the confluence of the Susitna Ri ver and Fog Creek,Rt1 176.7, GC S3'N04E16DBB,1982 S·c " Table 5-C-19 Selected mainstem water quality dat3 cnllecte r :~~·,[11ediatel':2rnlle the confluence of the Susitna River and Tsusena Creek,Rt·1 181.3, GC S3~N04E36ADR,1982 5-(II Table 5-C-20 Selected mainstem water Quality data collected immediately above the confluence of the Susitna River and Deadman Creek,RM 186.7, ICC S32N05E26CDB,1982 S'C ~'1.. TabsC/rapup Table 5-C-21 Table 5-C-22 Selected mainstem water quality data collected immediately above the confluence of the Susitna River and \>Iatana Creek,RM 194.1, GC S32N06E25CCA,1982 . Selected mainstem water quality data collected immediately above the confluence of the Susitna River and Kosina Creek,RM 206.8, GC S31 N08E15BAB,1982 .!:>--c -J J Table 5-C-23 Selected water quality data collected in Lower Jay Creek Slough, RM 208.1,GC S3HlO8EllDCD,1982 S--C-I.:3 Table 5-C-24 Selected water quality data collected in Un,per Jay Creek Slouq.h,S-c:-i~RM 208.7,GC S31N08E13BCD,1982 . Table 5-C-25 Selected mainstem water quality data collected immediately above the confluence of the Susitna River and Upper Jay Creek Slough,RM 208.7,_(_.~ GC S31N08E13BCD,1982 b- Table 5-C-26 Selected mainstem water quali~y data collected immediately above the confluence of the Susitna River and ~oose Cr~ek,RM 231.3,.__("-j-5" GC S,)nN11E32 DBC,1982 . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...~- Table 5-C-27 Selected mainstem water quality data collected immediately above the confluence of the Susitra River and Cshetna River.PM 233.4, GC S30Nll E3'~CCD,1982 S-c:-I j- Table 5-C-28 Selected water quality data collected in Sally Lake, GC S32~l 07E29,1982 . . ....... . . . . . . . . . . . . . . . . . . . . . . ...5 -c -k ..x:X\ VOLV/FIGURES/PAGE4 830209/Gene TABL5/Appendix B Figure APPENDIX 50 LI ST OF FIGURES Figure 5-0-1.Planimetric map symbol legend for selected mainstem Susitna River habitat evaluation sites,Proposed IJT1poundment Areas,1982..........................5-0 '-1 Figure 5-0-2.Mainstem Susitna River habitat evaluation site No.1,RM 189.0, GC S32N06E31ABC..................................~-O-~ Figure 5-0-3 Mainstem Susitna River habitat evaluation site No.2,RM 191.5, GC S32N06E28CAC..................................5 --0 -3 Fiqure 5-0-4 Mainstem Susitna River habitat evaluation site at Watana Creek, RM 194.1,GC S321'l06E25CCA 5-0 -I~ Figure 5-0-5 Mainstem Susitna River habitat evaluation site No.3,RM 197.8, GC S321'l07E330BC _:;-D -}:)- Figure 5-0-6 Mainste~Susitna River habitat evaluation site No.4,RM 201.2, GC S31N07El2BCB ..............•...................5-0-f..., Figure 5-0-7 Mainstem Susitna River habitat evaluation site No.3A,RM 201.6, GC S31N07El?-BOB .J..-_1'1 ..:7 -'L'I Figure 5-0-8 Mainstem Susitna River habitat evaluation site No.5,RM 208.1, GC S31 NOEl E11 OCD.•• ••• •••••••• ••• •• ••• •••••. ••• •••_')--0-E, 5.CONTRIBUTORS Aquatic Habitat and Instream Flow (AH) Project Leader Resident and Juvenile Anadromous (RJ) Project Leader Impoundment Study Sub-Project Leaders AH Sub-project leader RJ Sub-project leader Data Processing Project Leader Data Processing Staff Graphics Typing Staff Editors Aquatic Habitat Investigations Resident Fisheries Investigations x~\\\ DRAFT FIVE/CONTRIBUTORS Christopher Estes Dana Schmidt Joe Sautner Mike Stratton Allen Bingham Ka thy Rowe 11 Gail Hienemann Donna Buchholz Carol Kerkvl iet Katrine Zozel Sally Donovan Ann Reilly Peggy Skeers Joyce Godin Lynn Watson Christopher Estes Dana Schmidt Steve Hale Drew Crawford Joe Sautner Gene Sandone r~i ke Stratton Jim Quinn DRAFT FIVE/ACKNOWLEDGEMENTS ACKNOWLEDGEMENTS We would like to express our gratitude to all the people and organi- zations that provided information or assistance to the Impoundment Study during the past year. We sincerely appreciate the support services provided by Acres American, Inc.,Air Logistics,Akland Helicopter,R&M Consultants,Inc.;and the u.S.Geological Survey. Appreciation is also extended to the Alaska Power Authority for funding this project and to 1.Trent,L.Bartlett,R.Dieryck.K.Watson.R. Logan.L.Heckart,M.Mi 11 s and other staff of the ADF&G for thei r administrative services support. DRAFT FIVE/I. 1.OBJECTIVES Impoundment study area (Figure 5-1-1)investigations were initiated in 1981 by a joint Aquatic Habitat and Instream Flow (AH)and Resident and Juvenile Anadromous Fish (RJ)study team to provide the basis for: 1)assessing the impacts of transforming the existing lotic environment within the boundaries of the proposed Watana and Devil Canyon reservoirs into one that is lentic;and 2)i dentifyi ng \','hether a lternati ve fi shery habitat is avail ab 1e in the immediate area surrounding the proposed reservoir for replacing fishery habitat lost within the impoundments to sustain the existing level of fish populations. To achieve the first goal,data were collected with the objectives of determining: 1)which habitats within the impoundment study area are utilized by various fish species on a seasonal basis; 2)the physical and chemical characteristics of these fishery habitats;anc 3)the seasonal distribution and abundance of fish populations within the proposed impoundment areas. 1 .,..__.._--.._-_._--- f'-.)PROPOSEDIMPOUNDMENTAREALIMITSOFIMPOUNDMENTSTUDYAREAFigure5-1-1Proposedimpoundmentstudyarea.1982. DRAFT FIVE/I. The second goal was not pursued duri ng the 1981 studies because of limited manpower resources. Investigations were therefore continued in 1982 to: 1)collect additional habitat and fishery data to more accurately characterize the fish populations and their seasonal utilization of habitats within the boundaries of the proposed reservoirs to further meet goal number one;and 2)collect habitat and fishery data to determine whether the reach of tributary immediately upstream of the impoundment boundaries contains similar habitat to that presently found at the mouths of these tributaries and if these upstream reaches presently support fish populations. 1.1 Aquatic Habitat Investigations To meet objectives one and two above the following six aquatic habitat tasks were pursued: 1)Measure the range of physical and chemical conditions of tributary and mainstem Susitnc River habitats within the boundaries of the proposed reservoirs; 2)Quantify the surface area and stream length of selected tributaries which ~"ould be inundated by the proposed Devil Canyon and Watana reservoirs; DRAFT FIVE/l. 3)Examine the physical and chemical conditions of selected tributary habitats immediately upstream of the proposed impoundment elevations (PIE); 4)Identify and evaluate the physical and chemical conditions which appear to be influencing the utilization and suitability of habitats associated with the various life stages of Arctic grayl i ng; 5)Evaluate the physical and chemical characteristics of Sally Lake;and 6)Identify and evaluate aquatic habitats within the impoundment study area that are presently util ized by adult anadromous fish species. 1.2 Resident Fisheries Investiqationsy The specific tasks for the 1982 season resident fisheries studies within the impoundment study area were: 1)Determine the distribution,abundance and migratory habits of A.rcti c grayl i ng; 2)Determine the distribution and relative abundance of selected resident fish species in the Susitna River; / I DRAFT FIVE/l. 3)Determi ne the abundance of 1ake trout and Arctic grayl i ng in Sa lly Lake; 4)Record biological information on fishes to provide information on survival and growth to eventually support an analysis of fish production within the reservoir study area;and 5)Identify Arctic grayling spawning and rearing locations \'lithin the impoundment and adjacent study areas. These data and the previous habitat data will provide much of the neces- sary information to ultimately evaluate the impacts of the reservoir on those areas to be inundated.The analysis of these data to further address the major goals of this study will be included in the Fisheries and Habitat Relationships report (see Preface). The 1982 impoundment study area includes the aquatic habitats within the boundaries of the proposed Devil Canyon and Watana reservoirs and a five mile study reach immediately upstream of the PIE of selected tributaries (Figure 5-1-1).The upper Susitna River basin from Devil Canyon to the Oshetna River is a remote wilderness area of high aesthetic and recreational value.Mountainous terrain dominates the area with elevations ranging from approximately 900 feet near the basin floor of Devil Canyon to almost 8,000 feet in some areas of the glaciated terrain in the Oshetna River basin.The landscape varies from treeless alpine tundra at higher elevations to low lying areas dominated by black spruce frequently ir,terspersed with muskeg bogs.Occasional DRAFT FIVE/l. stands of cottonwood,bi rch and aspen are often found throughout the area,especially at lower elevations. According to projections by Acres American (Acres 1982)the two proposed impoundments would inundate approximately 84 miles of the mainstem Susitna River.This would include most of the reach of the Susitna River from the proposed Devil Canyon dam site (RM 152.0)upstream to a point approximately five miles above the confluence of the Susitna and Oshetna rivers (RM 239.0).A three mile reach of the Susitna River immediately downstream of the proposed ~~atana Dam site wi 11 not be inundated.The combined surface area of these two reservoirs would be approximately 45,800 acres.The proposed Devil Canyon Dam would create an impoundment 26 mi 1es long with a surface area of 7,800 acres.The maximum probable flood elevation is projected at 1,466 feet mean sea level (~lSL)with a normal operating pool level of 1,455 feet MSL.The proposed Watana Dam (RM 184.0)would create an impoundment that would extend 55 mi 1es upstream from the dam and cover 38,000 acres.The maximum probable flood elevation of this impoundment is projected at 2,200.5 feet ~1SL with a normal operating pool level of 2,185 feet ~iSL (Acres 1982). Prior to initiation of the 1981 Susitna River Hydroelectric Aquatic studies,fisheries and 2quatic habitat data fer this area cc~sisted of various preliminary environmental assessments (U.S.Fish &Wildlife Servi ce 1952, 1954, 1957,1959a,b,1960,1965;ADF&G,1978).These DRAFT FIVE/l. studies define species composition and highlight selected habitat locations and issues of particular concern,but because of their limited scope,were unable to quantitatively examine resident fish populations and their relationships to the aquatic environments. 7 DRAFT FIVE/2.0 2.METHODS 2.1 Study Design The 1982 Aquatic Studies program in the proposed impoundment study area was conducted during the open water field season (May-Oct.)on a monthly basis "Jith field activities lasting from 14 to 18 days per month. Additional field trips were conducted in late April and early ~Iay to determine timing,location,and extent of Arctic grayling spawning activities.These trips lasted from three to six days. Boundaries of the proposed impoundments were defined to differentiate betv.leen habitats above and below the proposed impoundment elevations (PIE).The impoundment boundaries for the Devil Canyon and Watana reservoirs were based on maximum probable flood elevations of 1,466 and 2,200.5 feet MSl respectively. The selection of 1982 study areas was based on preliminary studies conducted by the ADF&G during 1981 (ADF&G,1981)and included eleven tributary,seven mainstem Susitna River,and one lake locations.The tributary sites included eight major tributary streams that were selected for detailed study:Fog,Tsusena,Deadman,Watana,Kosina,Jay and Goose creeks,and the Oshetra River.In addition,eight other sites (seven on the mainstem Susitna River,and Sally Lake)were selected for detailed study in 1982.Three tributary streams in Devil Canyon: Cheechako,Chinook and Devil creeks;and selected mainstem slough DRAFT FIVE/2.0 habitats were also examined to obtain baseline data on resident fish species present and to conduct a general evaluation of the aquatic habitat available in these areas. The lakes,mainstem Susitna River,and the reach of the 11 major tributaries within the proposed impoundment boundaries investigated during 1982 were designated as habitat evaluation locations.Specific study sites within these habitat locations were designated as habitat evaluation sites. Each tributary habitat evaluation location consists of the mouth,and the tributary upstream to the PIE.The mouth encompasses that area of the Susitna River which is influenced by the tributary stream flow (the clear/turbid water mixing zone),and that area of the tributary which is influenced by the rise and fall of the Susitna River.The Illainstem habitat evaluation location consists of that portion of the mainstem Susitna River affected directly by the proposed Devil Canyon and Watana reservoir (R~1 152 to 239).Since it was not feasible to regularly sample all of this area,specific habitat evaluation sites were selected for study within this reach.All of Sally Lake is included in the Sally Lake habitat evaluation location.No other lakes within the proposed impoundment boundaries were studied during 1982. All tributary habitat evaluation locations were divided into reaches of stream according to habitat types or by using other physical charac- teristics as reference points (e.g.,pools,cliffs,tributary streams). LlI DRAFT FIVE/2.0 These points were then assigned a tributary river mile (TRM)to assist in identifying various reaches of the streams. The Oshetna River and Kosina Creek,the two largest tributaries in the proposed impoundment areas,were di vi ded into three di st i nct habitat types:(l)the mouth (confl uence habita t);(2)the maj or pools and (3) the riffle areas.The delineation of the major pool/riffle areas was based subjectively on streamflow velocities and depths determined by visual observations.Clearly defined habitats,characterized by deeper water and relatively moderate to low stream velocities were designated as pool habitat evaluation sites.Reaches of stream between pools cha racteri zed by shallower water and hi gher stream vel ociti es were designated as riff1e habitat evaluation sites.Beginning at the PIE, and moving downstream,each pool and riffle was assigned a letter and corresponding TRM for identification. Due to its length,the proposed impoundment reach of Watana Creek,11.9 miles,could not be effectively sampled in its entirety.Therefore, representati ve reaches of each habitat type encountered were sampled. These sections included both the East Fork and West Fork from their confluence to the PIE,and a two-mile section between TRM 4.0 and TRM 6.0. DRAFT FIVE/2.0 2.2 Aquatic Habitat Investigations Aquatic Habitat data referred to in this section was collected according to procedures presented in Volume 4 unless indicated otherwise. 2.2.1 Topographical and General Physical Characteristics of Po,quat ic Habitats Elevations at the mouths of tributaries,and water surface areas were determined from blue-line maps (scale 1"=400',with 10'contour in- tervals)developed by R&M Consultants,Inc.,North Pacific Aerial Photos and Ai r Photo Tech (1978 -1982).Stream gradi ents and the 1ength of proposed inundated tributary reaches were determined from blue-line maps (scale 1"=1000',1981)developed by Acres American and North Pacific Aerial Photos,Inc.Drainage basin areas were determined from USGS topographical maps (1:63360 series).The surface area measurements, stream gradients and stream lengths,were derived from the appropriate maps utillzing a Numonics 2400 electronic graphics calculator (digitizer). Stream widths and depths were visually estimated in the field and should only be considered as a gross approximation of these characteristics as observed during the 1982 sampling period. Substrate compositions were visually assessed and categorized accordi~g to the size classification scheme outlined in the 1982 ADF&G Procedures Manual (ADF&G 1982a). !i .J L 2.2 ..2 Water Quality DRAFT FIVE/2.0 General water quality parameters (dissolved oxygen,pH,specific conductance,water temperature,and turbidity)were measured at least once per month during the open water field season at designated tribu- tary,mainsteam and lake sampling sites.These sites were selected as being representative for those habitat evaluation locations under study. Tributary sites were located immediately above the mouth of Fog, Tsusena,Deadman,Watana,Kosina,Jay and Goose creeks and the Oshetna River.Mainstem Susitna River sites were located immediately above the confluence of the above-mentioned tributaries and the Susitna River with the exception of Jay Creek,where the sampling site was located immediately above the confluence of upper Jay Creek Slough and the Susitna River.Sally Lake was sampled once a month at a site at the west end of the lake.Sites one mile above the PIE of selected tribu- taries were sampled once during the field season.Additional sites, including minor tributaries and tributary study sections were sampled at irregular intervals.Samplirg incidence varied amorg all sites due to sampling priority and/or proximity to base camp. Dissolved oxygen saturation levels were determined from dissolved oxygen concentration,water temperature,and site elevation using an oxygen saturation nomograph (Wetzel 1975). Ryan t"odel J-90 thermographs were placed r.ear the mouth of Tsuser.a, ~!atana,Kosina and Goose creeks and the Oshetna River to continuously monitor surface water temperatures.These tributaries were selected as !2. DRAFT FIVE/2.0 thermograph sites based on their importance in providing surface water temperature data for reservoir modelling,and for grayling habitat evaluations. 2.2.3 Discharge Discharge data were collected to obtain baseline data for reservoir modelling and to determine relative differences in discharge for com- pari sons of fisheries habitat in tributaries under study. Monthly tributary discharges were measured with a Price AA flow meter when water velocities and depths permitted wading.Fog,Tsusena, Watana,Jay and Goose creek discharges were measured in the tributary reach upstream of the mouth.Discharge data in Deadman Creek were collected approximately three miles above the mouth because of hazardous sampling conditions in the lower reaches of the stream.Sampling sites were selected on the basis of channel morphology,substrate size,stream velocities and water depths. 2.2.4 Lake Mapping and Morphometric Data A depth contour map of Sally Lake was developed by plane table methods (Plate 5-2-1)using procedures similar to those presented in Lind (1974).Depth profiles were obtained utilizing a depth sounder (Lowrance,Model LRG-1510B)mounted on an outboard powered boat travell i ng at constant speed between poi nts on specifi ed transects. ---------_._.,_..~------_._--._--- r ~ ~. '-. Q.! ..:><: ro -J >, <0 V1-'-.~ 4-'"0 0"c: 0. 0. <0 E v, a.:=e::r c -. ~ U Q) +J ._. Q.! .D <0 +J Q) c: <0 Cl.. I N I LD (]j +J <0 Cl.. e : ~ DRAFT FIVE/2.0 These profiles were recorded on a printout and used to determine place- ment of depth contours on the map. The surface area of Sally lake was determined by polar planimetry (Lind 1974).All other data associated with lake morphometry were derived according to procedures described in Wetzel (1975). -------._-_._-"~... DRAFT FIVE/2.0 2.3 Resident Fisheries Investigations The majority of tributary habitat evaluation locations were sampled in their entirety at least once a month.All sampling conducted above the mouths of the eight tributaries was by and hook and 1 ine.Assorted spi nners and fl i es,both wet and dry,were used.t~a i nstem habitat locations were sampled for two consecutive 24 hour periods each month. Sampling gear utilized at the mainstem sites and tributary mouths included trotlines,gillnets and hook and line.Sally Lake was sampled as time,work load,and transportation availability permitted.Hook and line,variable mesh gi11nets and hoop nets were deployed at various locations in Sally Lake. A detailed discussion on methodology of quantitative data collection and sampling techniques is provided in the Procedures ~anual (ADF&G,1982a). Descriptive data (i.e.,observation of juveniles,non-quantified habitat observations,fish behavior)were recorded daily in field notebooks for future reference. A standard tagging and recapture scheme was used to study seasonal migrations and generate population estimates for selected resident fish speci es .All res i dent fi sh speci es over 135 mill imeters (mm)fork lergth (FL)and in good condition after capture were tagged using international orange Flay anchor tags inserted just posterior of the dorsal fin (Plate 5-2-2). I·,c -----------------_._. -..J"Plate5-2-2yI\,I'y)~~"",........."~....~"'"'"I."i.at"Aa~......4..._ArcticqraylingimplantedwithFlayanchortag. - DRAFT FIVE/2.0 Population estimates generated from the 1981 field data provided a preliminary estimate of grayling populations in the proposed impoundment areas.Many biases associated with these estimates have been iden- tified.These include:lack of randomness of recapture effort,hetero- geneity within the populations (catch rates are not the same and tagged/recapture ratios vary within the segments of the population),the population is not closed geographically (immigration and emigration do occur),and time changes affect the estimate. In order to address some of these biases in the estimates,several changes in the study design and the analytical procedures have been instigated. The division of Kosina Creek and the Oshetna River into the pool and riffle reaches described previously was based on the assumption that the probability of capture within these reaches will differ substantially. Therefore,the population estimates can address each of these sub-areas separately. Secondly,the data base has been stratified by length classification based on the age-length relationship for the entire study area.Ex- amination of the specific age classes for differences in the tagged/re- capture ratios can provide an indication o~the afTlour.t of bias due to heterogeneity. Finally,the actual statistical methods employed for calculating the population estimates and their confidence levels have been changed.The DRAFT FIVE/2.0 1981 estimates were generated using a Schnabel Multiple Census estimator while the 1982 estimates employ an adjusted Petersen single census estimator.A detailed description of the estimator is given in Appendix 5A. Ultimately,the population estimate produced will address the individual streams,their unique biases,and biases associated with our sampling techniques. Instantaneous survival rates for Arctic grayling are calculated using catch,length,and age data from the effectively sampled portion of the population.The resulting rate can be applied to the entire population, since fishing mortality is insignificant and natural mortality is the only factor influencing the survival rate.The actual statistical method is provided in Appendix 5A. CRAFT FIVE/3.0 3.RESULTS 3.1 Tr'ibuta ry Fi sheri es and Habitat Investi gati ons 3.1.1 Aquatic Habitat Investigations The general habitat characteristics of eleven major tributaries in the proposed impoundment areas are presented below.Specific information on the topographical features of each stream is presented in Tables 5-3-1 and 5-3-2.A stream gradient profile of the impoundment study area is presented in Figure 5-3-1.Maps of the proposed inundated reach of the eleven major tributaries and adjacent Susitna River are presented in Appendix 58,Figures 5-8-1 to 5-8-11. 3.1.1.1 General Stream Description Cheechako Creek Cheechako Creek enters the Susitna River from the south at river mile 152.4 approximately one half mile upstream of the proposed Devil Canyon dam site (Appendix Fi gure 5-8-1).It is the most downstream major tri buta ry to the Sus itna Ri ver withi n the proposed impoundment study area.P,pproximately the first 1.7 miles cf the tributc;ry would be inundated by the proposed Devil Canyon impoundment.The steepness of the terrain and time constraints limited ground surveys of this tributary to the vicinity of the mouth.Aerial surveys were conducted from the tributary mouth upstream for a distance of approximately three mil es. Table5-3-1.lIo15/TABLES/PAGE1830208/JOETABL5/TopoFeaturesaTopographicalfeaturesofselectedtributariesoftheproposedDevilCaryonimpoundment,1982.ApproximateCharacteristicsofTributaryGradientofTributaryElevationSizeofReachtobeInundatedImmediatelyAbovePIEGeographicCodeAtConfluenceDrainageSurfaceSusitnaAtConfluenceWithSusitnaBasinLengthAreaGradientl-Mi1e5-MileTributaryRivp.r11ileWithSusitna(ftMSL)(sqmi)(mil(acres)(ft/mi)(ft/mi)(ft/mi)CheechilkoCreek152.4S32N01E33CCB92036.41.7---321N/A N/AEastF0rkN/AN/A1620bN/AN/A~l/AN/A331338WestForkN/AN/A1620bN/AN/AN/A~l/A344267i'JChinookCreC'k157.0S31t!02t:Q6CAC106522.41.33.4308357203• I!-DevilCreek161.4532N02E34AAC120073.61.57.7176344203FogCreek176.7531N04E16DBB1375147.21.311.272158100TSlIsenaCreek'181.3532tl04E36ADS1435144.50.45.48245111abPropaspdImpoundmentElevation(PIF!-1466FeetMSLElevationatConfluenceofTributaryForksDataUnavailable Vo15/TABLES/PAGE2830208/JOETABL5/TopoFeaturesTable5-3-2.TopographicalfeaturesofselectedtributariesuftheproposedWatanaimpoundmenta,1982.ApproximateCharacteristicsofTributaryGradientofTributaryElevationSizeofReachtobeInundatedImmediatelyAbovePIEGeographicCodeAtConfluenceDrainageSurface:',usitnaAtConfluenceWithSusitnaBasinLengthAreaGradientl-Mile5-MileTributaryRiverMileWithSusitna(ftMSL)(sqmi)(mi)(acres)(ft/mi)(ft/mi)(ft/mi)DeadmanCreek186.7S32NOSE26CDB1515175.12.724.52535362\'IatanaCreek194.1S32N06E25CCA1550174.88.570.560bN/A N/AEastForkN/AN/A2060cN/A1.26.111310398VlestForkN/AN/A2060cN/A:'.110.4676559I"-KosinaCreek206.8S31N08E15BAB1670400.24.579.711812590;:JayCreek208.5S31N08E13BCC169561.83.515.714315895GooseCreek231.3S30NllE320DC2060103.91.210.6114141125OshetnaRiver233.4S30NllE34CCD2110555.02.243.1416160abcProposedImpoundmentElevation(PIE)-2200.5FeetMSLWatanaCreekbelowforksElevationatConfluenceofTributaryForks RELATIVETRIBUTARYMILES240230220•TRIBUTARYRIVERMILE[]PROPOSEDIMPOUNDMENT210\WATANADAN180190200SUSITNARIVERMILES170160CANYONDAM...V)Iu132003000~2800---l(j):::E2600Q)>~24000+-j\J::2200~.............Z02000-~q:>1800w---lW1600140012001000800~150Figure5-3-1GradientprofileoftheproposedimpoundmentreachoftheSusitnaRiverandmajortributaries. DRAFT FIVE/3.0 Cheechako Creek is a high gradient clearwater stream originating on the north slope of the Talkeetna Mountains.It flows in a southerly direction for approximately 10 miles from its source to its confluence with the Susitna River and has a total drainage basin area of 36 square mil es.The stream forks approximately 2.2 mil es upstream from the mouth formi ng an east and a west fork.A small 1ake drains into the system near the headwaters of the west fork.The upper reaches of the east and west forks flow through open tundra areas with habitat consist- ing predominantly of riffle areas with relatively high streamflow veloc- iti es.The lower reach of the stream is confi ned to a deep,steep- walled canyon with numerous rapids and a few small waterfalls. The reach of stream which would be inundated by the proposed impoundment has a gradient of 321 feet per mile.This relatively high stream gradient results in high streamflow velocities with long stretches of turbulent,cascading whitewater areas interspersed with a few relatively large deep pools.The narrow stream channel,situated in a deep V-shaped canyon,is between 20-30 feet wide with depths between 2-4 feet.The substrate is composed mainly of large boulder and cobble with smaller rubble and gravel confined to pool areas. During the open water field season the clearVla~er plume of Cheechako Creek,approximately 60 feet long and 10 feet wide,extended downstream into the Susitna River.This area provided excellent although 1imited s2.lmon spawning habitat.Substrate consisted rr:ainly of gravel,and streamflow velocities were moderate.Limited numbers of chinook sal~on DRAFT FIVE/3.0 were observed utilizing this habitat for spawning during late summer (refer to Volume 2).Prior to this observation,an unconfirmed report that this tributary was util ized by salmon was presented in:Progress Report 1957 Field Investigations Devil Canyon Dam Site One Reservoir Area,Susitna River Basin Area (USFWS 1959). Chinook Creek Chi nook Creek enters the Sus itna Ri ver from the south at ri ver mil e 157.0 approximately five miles upstream of the Devil Canyon dam site (Appendix Figure 5-B-2).The first 1.2 miles of stream would be inundated by the proposed Devil Canyon impoundment. The steepness of the terrain and time constraints prevented ground surveys;however,aerial surveys of the stream were conducted upstream from the mouth to approximately TRM 4.0. Chinook Creek is a clearwater stream which originates from several small drainages on the north slope of the Talkeetna Mountains.It and flows north for approximately 10 miles from its source to its confluence with the Susitna River and has a total drainage basin area of 22 square miles.The stream is mostly confined to a deep V-shaped canyon characterized by steep gradients and high streamflow velocities through- out most of its reach.Several waterfalls and rapids,which may con- stitute velocity barriers to fish,exist both above and below the PIE. DRAFT FIVE/3.0 The reach of stream which would be inundated by the proposed impoundment winds through a steep,narrow canyon with a stream gradient of 308 feet per mile.This steep gradient results in high streamflow velocities with large areas of whitewater and few pools.Stream widths are between 20-30 feet with average depths of 2-4 feet.Substrate consists mainly of large boulder and small cobble.Although spawning salmon have been observed approximately one half mile upstream from the mouth,areas of suitable salmon spawning habitat are limited to a few pools where gravel substrate and moderate streamflows are available.The USFWS (l959a) also reported unconfirmed sitings of salmon spawning in this creek. Devil Creek Devil Creek enters the Susitna River from the north at river mile 161.4 approximately nine miles upstream of the proposed Devil Canyon dam site (Appendix Figure 5-B-3).The first 1.5 miles of this stream would be inundated by the proposed Devil Canyon impoundment. Access to the area is limited because of the steepness of the terrain. Therefore,ground surveys were only conducted once in the lower mile of the stream.Aerial surveys were conducted from the mouth of the tributary to approximately TRM 5.0. Devil Creek is a clearwater stream originating from various drainages in a mountainous region immediately south of the Alaska Range.The stream flows generally south for approximately 15 miles from its source to its confluence with the Susitna River and has a total drainage basin area of DRAFT FIVE/3.0 74 square miles.Several small lakes drain into the stream along its course.A large waterfall approximately 100 feet in height is located two miles upstream from the mouth.This waterfall effectively divides the stream into two distinct reaches.The area above the falls flows through open tundra areas with relatively low gradients.Below the falls the stream is situated in a deep steep-walled canyon with higher stream gradients. The reach of stream which would be inundated by the proposed impoundment is characterized by high streamflow velocities,turbulent whitewater areas,and relatively large,deep pools.The stream gradient in this reach is 176 feet per mile.Substrate is composed predominantly of large boulder and cobble with smaller rubble and gravel being confined mainly to pool areas.Stream widths range from 30-40 feet with average depths between 2-4 feet.Some of the large pool areas were in excess of five feet deep.These large,deep pools were found to be the preferred habitat for the 1imited numbers of resident Dolly Varden which "'Jere found in this reach of the stream. Fog Creek Fog Creek flows into the Susitna River from the southeast at river mile 176.7 (JI.ppendix Figure 5-8-11.).The mouth of the stream is locatEd approximately 24 miles upstream of the proposed Devil Canyon dam site. The first 1.2 miles of stream would be inundated by the proposed Devil Canyon impoundment. ,7 .",I DRAFT FIVE/3.0 The stream was sampled from the mouth to TRM 0.5 on a regular basis during the open water field season.The reach of stream upstream of this lower reach was not sampled because it is located on native land claims and permission for access was denied.Aerial surveys were conducted from the mouth upstream for a di stance of approximately ten mil es. Fog Creek is a clearwater stream which originates on the north slope of the Talkeetna Mountains.It flows in a general northwest direction for approximately 20 miles from its source to its confluence with the Susitna River and has a total drainage basin area of 147 square miles. The headwaters of the stream flow over steeply sloping terra'in for several miles before reaching the foothills of the Talkeetna Mountains where the terrain becomes less steep.From this point the stream meanders over the tundra for several mi 1es before it enters a deep V-shaped canyon.Within this reach a system of five large lakes drain into the stream approximately six miles upstream from the mouth.Below this reach much of the stream \!-linds through a deep,narrow,steep gradient canyon to a point approximately are mile from its mouth where the gradient begins to decrease. The reach of stream which would be inundated has a relatively low gradient of 66 feet per nlile.Stream habitat ccnsists predominantly of shallow riffles with few pools.Stream widths range from 50-75 feet and average depths are 2-3 feet.Substrate consists mainly of rubble and cobble.IVlost of the stream 'tJithin the study area is confined to one stable charnel although braided crannels occur in a few areas near the DRAFT FIVE/3.0 mouth.During periods of high discharge many backwater areas were present in this reach.Studies in 1981 (ADF&G 1981a)indicated that resident fish species utilized these backwater areas when they were available. Tsusena Creek Tsusena Creek enters the Susitna River from the north at river mile 181.3 (Appendix Figure 5-B-5).It is the most upstream tributary to the Susitna River within the proposed Devil Canyon impoundment that was studied.It is located 29 miles upstream of the proposed Devil Canyon dam site.The first 0.4 miles of stream would be inundated by the proposed impoundment. Ground surveys of the reach to be inundated were conducted on a regular basis during the open water season.Additional sampling was conducted twice in areas approximately 1-2 miles upstream of the mouth.Aerial surveys were conducted from the tributary mouth to approximately TRM 10. Tsusena Creek is a clearwater stream originating in steep,mountainous terrain on the southern edge of the Alaska Range.The stream flows south for approximately 30 miles from its source to its confluence with the Susitnc:River ana has a total drainage basin area of approximately 144 square miles.One major tributary,Clark Creek,enters the stream approximately six miles above the mouth.There are no major lakes accessible to fish within the drainage basin.Below its headwaters the DRAFT FIVE/3.0 stream flows across an open tundra region of relatively moderate gradi- ent.A large waterfall,located approximately three miles upstream from the mouth,divides the stream into an upper and lower area.The stream is situated in a deep V-shaped canyon for approximately two miles in the area adjacent to the falls.Below this area the stream valley broadens and gradient decreases to its confluence with the Susitna. Due mainly to the extreme upstream location of Tsusena Creek in the proposed Devil Canyon impoundment it will only be affected upstream from the mouth for a distance of 0.4 miles depending on fluctuations in the impoundment elevation.This reach of the stream is approximately 75-100 feet wide and the habitat consists primarily of shallow riffles with a few small pools approximately 2-3 feet in depth.Substrate consists of large cobble and boulder ernbedded in sand (Plate 5-3-1)with small gravel confined mainly to pool areas.The stream channel spl its near the Susitna River resulting in the formation of two separate channels at the mouth approximately 150 feet apart with a large gravel bar in between. During periods of high discharges observed in Tsusena Creek in 1981 which followed heavy precipitation events,a clear water plume from Tsusena Creek was observed to extend approximately one half mile downstrhlll into the Susitr.a River.riany grayl ing were ceught in this area during the 1981 open water field season.Discharges in 1982 were reduced from those observed in 1981 as was the clearwater plume. Relatively fewer grayling were also caught dovmstream of the rllOuth in 1982 as compared to 1981. ••\0..•• I ..r ~...<l:"" -,"'" ,0 "", "......~..' .';.~ ." " " ,..<, .,.. '\l-, 1\ .. " "~.. DR-AFT FIVE/3.0 Deadman Creek Deadman Creek enters the Sus itna Ri ver from the north at ri ver mil e 186.7 approximately 2.7 miles upstream of the proposed Watana dam site (Appendix Figure 5-B-6).It is the lowermost tributary habitat evaluation location in the proposed Watana impoundment area.The stream would be inundated upstream from the mouth for 2.7 miles. The stream was divided into an upper and lower reach for sampling purposes because of a deep canyon and large waterfall past the first half mile.Only the lower one half mile of stream below the canyon was sampled regularly during the open water field season.A one mile section immediately above the falls was sampled on two occasions before sampling was suspended because of limited success in catching fish in this whitewater reach.The reach of stream within the canyon,approxi- mately one half mile in length,was not sampled because it was inacces- sible. Deadman Creek is a clearwater stream originating in an open tundra region just south of the Denali Highway.The stream flows generally south for approximately 40 miles from its source to its confluence with the Susitna River and has a total drainage basin area of 147 square miles.{l,large lake,Deadman Lake,is locatEd within the system approximately 16 miles upstream from the mouth.The reach of stream above the lake consists of several smaller drainages which converge to form the main chanrel of Deadman Creek.Belovi the lake the stream DRAFT FIVE/3.0 habitat consi sts of long riffl es,turbul ent whitewater and occasi ona 1 areas of deep,slow flowing,placid water with low stream gradients. The reach of stream which would be inundated is confined mostly to a deep,narrow canyon with a re 1ati ve ly steep gradi ent of 251 feet per mile.This area is characterized by high streamflow velocities and turbulent whitewater areas resulting in few pools with little cover for fish.Channel widths are between 75-100 feet with depths of 3-5 feet. Substrates consist mostly of large boulder and cobble.A 1a rge waterfall,which is presently a barrier to upstream fish migration,is located 0.6 miles upstream from the mouth.The proposed Watana impound- ment would inundate the waterfall and allow fish migration between the upper areas of Deadman Creek,Deadman Lake,and the Susitna River. Watana Creek Watana Creek drains into the Susitna River from the north at river mile 194.1 approximately 10 miles above the proposed Watana dam site (Appe- ndi x Fi gure 5-B-7).Due rna in ly to the low gradi ent of the stream channel the total length of stream that would be inundated by the proposed reservoir is 11.9 miles.This includes 8.5 miles of the mainstem of Watana Creek from the mouth to its confluence with the east ana west forks,and 1.3 and 2.1 mile5 of each fork respectively. Time and personnel limitations precluded sampling of this entire reach. Therefore,three subsections of the stream were selected to be used as index areas during the regular sampling season as described earlier in DRAFT FIVE/3.0 this report (see Methods Section 2.1).These sections were sampled as stream turbidity levels allowed.Aerial surveys were conducted upstream from the mouth to approximately five miles up each fork. Watana Creek ori gi nates ina regi on of open tundra just south of the Denali Highway.It has a drainage basin area of 175 square miles.It is generally a c.learwater stream but is often turbid in summer due to runoff from melting permafrost and other unstable soils in upstream areas.The main fork of Watana Creek (east fork)flows generally south for approximately 23 miles from its source to its confluerce with the Susitna River.The west fork joins the east fork 8.5 miles upstream from the mouth and is approximately 12 miles in length. Several lakes are located in the drainage basin mostly in the upper reaches.Many of these are small,shallow lakes situated on the tundra. One large unnamed lake drains into the east fork and another relatively large lake,named Big Lake,drains into the west fork.Sally Lake,63 acres in size,drains into Watana Creek approximately one mile upstream from the mouth. Stream habitat between the east and west fork varies considerably within the habitat evaluation location.The east fork is confined to a well defined stream channel \'Jith steep ccr.yon walls arc the gradierlt (112 feet/mile)is almost twice that of the west fork (67 feet/mile).Small waterfalls on the east fork may hinder upstream movement of fish. Several large,deep pools are interspersed between the predominant riffle areas.Stream habitat in the west fork consists mainly of long, ----------_.._._...-._---------_._-------- DRAFT FIVE/3.0 shallow riffle areas with few pools.Substrates differ within and between forks primarily on the basis of local stream velocities.Gravel and rubble,often embedded in sand,is prevalent in riffle areas with moderate streamflow velocities and pools.Cobble and boulder is more common in areas of higher streamflow velocities.Stream widths on each fork vary between 30 and 50 feet with average depths of 2-3 feet. Below the confluence of these two forks,changes in Watana Creek occur gradually.Along this reach to the mouth,stream valley walls steepen although the floor widens,stream channel ~Jidth generclly increases and stream gradient decreases.Stream widths in this reach are between 40-60 feet with average depths of 2-4 feet.The shall ow pool-riffl e type habitat present in the forks persists in this lower reach.Howev- er,because of the increased volume of water and widening of the stream channel,it becomes less defined.Substrate differs little from substrate described earlier in the forks.Unstable soils due mainly to melting permafrost resulted in higher stream turbidities within this reach.This condition prevailed in the lower 3-4 miles of Watana Creek throughout the 1982 field season. Kosina Creek Kosina Creek enters the Susitna River from the south at river mile 2C8.6 approximately 24 miles upstream from the proposed Watana cam site (Appendix Figure 5-8-8).The proposed reservoir would inundate 4.3 miles of the stream. DRAFT FIVE/3.0 The habitat evaluation location was sampled monthly during the open water field season.Sampling was conducted once during July on the 1.5 mile reach of stream immediately above the PIE.Aerial surveys were conducted on the main fork of Kosina Creek upstream from the mouth for approximately 10 miles.Aerial surveys were also conducted along Gilbert Creek to Clarence Lake and on selected major tributaries to Kosina Creek. Kosina Creek is a relatively large clearwater stream which originates in steep mountainous terrain just south of the Tal keetna Mountains.It flows generally north for approximately 35 miles from its source to its confluence with the Susitna River and has a drainage basin size of 400 square miles.Several major tributaries drain into Kosina Creek along its course.Two of the more important tributaries,Terrace (TRM 15.5) and Gi"1 bert (TRM 5.8)creeks drain 1a rge 1ake systems whi ch presently support populations of Arctic grayling and lake trout.Several other lakes are located on the tundra plateau above the valley floor and are drained by small high gradient outlet streams which do not appear to be accessible to fish. The stream habitat in Kosina Creek varies considerably along its course. The upper reaches are characterized by broad valleys of glacial origin v.Jith relatively n,odera-ce streamflovJ velocities.Meandering braided channels are common in this area.Approximately ten miles upstream from the mouth the gradient increases and the stream is more confined to a V-shaped valley.Long,fast flovlirg riffle areas are the dominant habitat type in this middle reach of the stream. DRAFT FIVE/3.0 The reach of stream below its confluence with Gilbert Creek is charac- terized by long stretches of high velocity riffle areas interspersed with numerous large,deep slow-flowing pools (Plate 5-3-2).These pools are located against cliffs,high banks or in areas behind large boulders.The pools are as large as 50 by 150 feet in area and up to 8-10 feet in depth.Substrate in the pools consists of varying proportions of cobble,rubble and boulder usually embedded in sand. Substrate in the riffle e.reas consists mainly of cobble and boulder. The stream channel is frequently braided in this reach.Stream widths are often in excess of 200 feet and depths average 3-5 feet. Jay Creek Jay Creek enters the Susitna River from the north at river mile 208.5 approximately 23 miles upstream of the proposed Watana dam site (Appendix Figure 5-8-9).It would be inundated upstream for 3.5 miles by the proposed impoundment. Sampling was conducted monthly during the season on the habitat eval- uation location..A.dditional sampling was conducted twice on the first mile of stream located immediately above the PIE.Aerial surveys were conducted upstream from the mouth to approximately TRM 8.0. Jay Creek is a clearwater stream originating in a gently sloping region of open tundra just north of the Susitna River.It flows in a general northwest direction for approximately 12 miles and then flows southwest for 8 miles to its confluence with HiE Susitna River.It has a rela- :'3$IJ.!:!":.;'. -~::~~. .;.,,:.~r. Plate 5-3-2 A tvpical,large,deeD COOl Impound~p"t Elev2tion (PIE) .-J C located below the Propnsed 4f1 Krc:;ini'l Creek . DRAFT FIVE/3.0 tively small drainage basin of approximately 62 square miles.One major unnamed fork,approximately 9 miles in length enters the stream eight miles upstream from the mouth of Jay Creek.The stream habitat of Jay Creek is characterized by moderate streamflows and alternating pool /riffle areas.Lentic environments in the drainage basin are limited to a few very small tundra ponds scattered throughout the area. The reach of stream which would be inundated is confined mostly to a deep,narrow canyon with a stream gradient of 143 feet per mile. Streamflows are moderate and the habitat consists mainly of riffle areas interspersed with numerous small pools mostly situated behind boulders or against cl iff areas.Stream widths are between 40 -60 feet with average depths of 2-3 feet.Substrate consists of gravel,cobble and rubble often embedded in sand.Although the stream is generally clear, unstable soils in upstream areas often result in landslides during periods of moderate to heavy precipitation and can rapidly increase the turbidity of the stream.The stream channel itself is stable.The channel spl its approximately 100 feet above its confluence with the Susitna River resulting in the formation of two distinct channels at the mouth.Due to the low discharge of the stream the clear water plume area which extends into the Susitna is confined to the immediate prox- imity of the mouth. Goose Creek Goose Creek drains into the Susitna River from the south at river mile 231.3 approximately 47 miles upstream of the proposed viatana dam site DRAFT FIVE/3.0 (Appendix Figure 5-B-1O).The stream would be inundated upstream for 1.2 miles by the proposed impoundment. Sampling was conducted monthly on the habitat evaluation location.A one mile section of stream immediately above the PIE was also sampled once during the season.The stream was not surveyed beyond this point. Goose Creek is a relatively small clearwater stream with a drainage basin area of 104 square miles.The stream originates in a steeply sloping region of open turdra south of the Susitna River and flows in a general north direction for approximately 20 miles to its confluence with the Susitna River.The stream habitat consists mainly of long riffle areas of moderate streamflow velocity and few pools.The stream is generally confined to one channel,although braided channels some- times occur in the upper reaches.Busch Creek,the only major tributary to Goose Creek,enters the stream approximately 15 miles upstream from the mouth.Numerous smaller tributaries drain into the creek along its course to the mouth.Several small lakes are located in the upper reaches of the drainage basin. The stream channel below the PIE is narrow and shallow throughout most of the reach and has a gradient of 114 feet per mile.Stream widths are between 30 arid 50 feet ane.:Gepths avel'age 2 to 3 feet.Long,ri ffl e areas dominate the habitat although deeper runs with lower streamflow velocities occur in a few areas.Substrate consists mainly of rubble, cobble and boulder in the riffle areas.Deeper areas with slower flows have substrates consisting mainly of gravel and rubble. DRAFT FIVE/3.0 Oshetna River The Oshetna River drains into the Susitna River from the south at river mile 233.4 approximately 50 miles above the proposed Watana dam site (Appendix Figure 5-B-11).It is the uppermost tributary habitat evaluation location within the proposed impoundment study areas.The stream woul d be inundated upstream for 2.2 mil es by the proposed im- poundment. Sampling was conducted monthly on the habitat evaluation location. Ground surveys were conducted on the first mile of stream located immediately above the PIE.Aerial surveys were conducted from the mouth upstream to approximately TRM 7.0. The Oshetna River originates in steep mountainous and glacial terrain east of the Susitna River at elevations approaching 7,000 feet.It drains an area of 555 square miles.It is the only tributary to be influenced by glacial activity which gives the water a blue-green appearance due to the light load of glacial flour present in the stream during the summer months.The mainstem Oshetna River flows in a general north direction for approximately 50 miles from its source to its confluence with the Susitna River. There are three distinct drainages in the upper reaches of this rela- tively large drainage basin.These ccnsist of the Black River,the Littl e Oshetna Ri ver,and the ree.ch of the Oshetna Ri ver above its confluence with the Little Oshetra River,hereafter referred to as the ·IL DRAFT FIVE/3.0 Upper Oshetna.These three streams are similar in morphology due to their glacial origin.They all flow through relatively flat,U-shaped, gl aci ated valleys with frequently braided stream channel s.All three drainages are presently affected to some extent by glacial activity. Two major lakes are located in this area,Black Lake and Crater Lake, both of them within the Black River drainage.Several smaller lakes are present along the Little and Upper Oshetna drainage. The reach of stream below the confl uence of the Bl ack Ri ver and the Oshetna River is characterized by a relatively high stream gradient and the stream channel is confined to a V-shaped valley with steeply rising valley \'/alls.Several large lakes are situated on the tundra plateau above the valley floor in this area with small,high-gradient outlet streams connecting them to the Oshetna River. Stream gradient begins to decrease approximately five miles above the mouth and the stream channel becomes meandering.The stream habitat in this reach consists mostly of long riffle areas (Plate 5-3-3)with moderate streamflow velocities.Several large,rather shallow pools are present in the lower two mil es of stream and many small pool type habits are located behind boulders in the stream.Substrate consists mainly of cobble and boulder in the riffle areas with rubble and gravel found more often ir pool type habitats.Stream widths t'0nge from 1CO to 125 feel: with average depths of 3 to 5 feet. ..w·rst ......,•••1 C n'dO ~ftT"'ee 4-o ",.....l VI :u OJ +-'Or- Or-+-' ..0 Or- 10 U ..c:0 ....-Q) 10 > U er-3: 0-0>.....- I-4- (Y") I (""; I LD DRAFT FIVE/3.0 3.1.1.2 Water Quality 3.1.1.2.1 Instantaneous Water Quality Instantaneous water qual ity and air temperature data for all tributary habitat evaluation sites are presented in Appendix Tables 5-C-1 to 5-C-17.Graphical representations of the range,mean and median values for each parameter at each habitat evaluation site are presented in Figures 5-3-2 to 5-3-7. Instantaneous water temperature observati ons for all tri buta ry eva 1- uation sites ranged from O.l°C in the Oshetna River on May 5,1982 to 14.8°C recorded in Goose Creek on July 28,1982.Lowest mean and median instantaneous water temperature were observed in Fog Creek while highest mean and medi an temperature occurred in the Oshetna Ri ver and Goose Creek respectively. The lowest instantaneous dissolved oxygen concentration of 9.6 mg/l was observed in Goose Creek and Watana creeks on JUlie 24,1982 ar.d in the Oshetna Ri ver on July 19,1982.Correspondi ng instantaneous surface water temperatures for those streams were at their highest at the time of this sampling.Highest dissolved oxygen concentrations,14.2 mg/l, occurred in Deadman Creek on May 5,lSJ82 whell water temperature was only 0.8°C.Mean and median concentrations were highest in Deadman Creek, 12.5 mg/l and 12.2 mg/l respectively.Lowest mean concentrations occurred ln Cheechako Creek,10.4 mg/l,while lowest median concentra- tion,10.3 mg/l,occurred in the Oshetno River. TEMPERATURE(OC)o01I I I I I II IoI IIII01IIIIINoI II-n=7• In=e• In=5n=4n=5n,=8n=6...I...I---+1"--n=3n=4n=4n=4n=4...I.,-I...II -• n=II_n=7n=39n=15n=7n=5n=en=7...I------.I_J----I_I...,-----'1Cl7eecl1akoCr.-0.8/6-8/11toc-tDevilCr.8/22,ro::0FogCr.5/5-9/12v"l-ICDC.vTstJsenaCr.•c5/5-9/12",)-t:t>DeadmanCr.5/5-9/11IJ1.......-sIf)~::0(f)w'3OJ;::m-<WatanaCr.5/5-9/20QJ"'Jv,OJ1>LI10-0.,t,~KosinaCr.3:5/4-9/14oeM-OJU>:=i~OJn,........-00-ri'ro.....JayCr.--,'3•r5/5-9/19::i(0--'ITt-II~.CD~,~U.JayCr.51.Z5/29-9/15L;;;ri";uU>G>;OJ_.roOJGooseCr.5/14-9/10"·'irD'C'~,roi:lJl.OOsl7etnaCr.-0:::::lOJM-ro5/5-9/9c::-I.c-tITt3il2~---"o-c.-J--o_::0rD,ro-.-s-I.)-U>FogCr.a6/21-9/12:::::lLI1OJC')'.0_.J.l-tOJCa"i)rl'C~U>TStJsenaCr.6/19-9/12".(D,0-0"-.,VlrP-i,.....,~Co(,1'3ZDeadmanCr.-6/19-9/1IwroCl.:t>tD""""5__1:£)......4WatanaCr.CO6/23-9/15..::...>.')-0.roOJ::0~(X)M-n~N-0.['0':::Y0<KosinaCr.....-6/27-9/14o~----J.}.--.....ITt::io::iQ1VlDro::0U.JoyCr.51.5/29-9/5-.-CD0_...--U>::ic+':::Y-0......GooseCr.5/14-9/10~m~~QJ'VlI'T1Osl7etnaR.5/27-9/9c+;;U>roOJl~',;DM-o-'OJ-i)0co~SallyLake6/23-9/8-0,0nroroU),~0--'tUrocCl..Cl.Cl..Vl DISSOLVEDOXYGEN(mgtI ).to(JItJ)-.jCD100=N~~(JI(]l""Tl---'.'.0;CheechakoCr.816-81IIin=3,1)In-.,DevilCr.8/22•n=II:::0~CDFogCr.5/5-9/12I•n=6wc-.,TsusenoCr.5/5-9/12I.n=7p.:::lCLroa.~::0DeadmanCr.5/5-9/11I.n=6§;~~~-<cr:::.~D::::lWafanaCr.CJ)5/5-9/19.1n=37~.o~~CJ):t:-o,~~-.,KosinoCr.~5/4-9114•In=15::'hrl;:::;.ntilrr1'1J::::J":Jaro::::l~~(j)JoyCr.r5I5 -9/15I·n=7vV"ln~Zf.:~~~~;oUJayCr.SI.(j)5/29-9/15•In=5""'\cororlOJ:;;NV"l~5GooseCr.5/5-9/10I •n=8c+<,-torn'1J---'.g::-;.C;.OshelnaR.ITI5/5-9/9I.n=7~'0~::::l,~:::0V"l::::l_••V"l_0~::::l,"\~(j)0OJ~roCFogCr._6/21-9/12•In=4~1)8cu(j)->'.:J13--.,TsusenaCr:~6/19-9112I•n=3-h3~3ZDeadmanCr.N6/19-9/11Ien=3---'.0roP-rna0.--,V"lOJ---'.WofanaCr.6/23-9/15~n=40.ro<'+OJ:::00..::l-4V"lV"l-<KosinoCr.6/27-9/14~n=rn---'.mrr1e;~ro"~1:::0UJoyCr.51.5/29-9/15•In=5aun::::l3;;~CJ)GooseCr.5/14-9/1aI•n=8/_~'jf0.,~.-.,::::lrg::::J-::,·rr10shetnaR.5/27-9/9,n=6rlOJV"l(j)IIere=>~---J.----J-;-""'\rl<I'Sll)OJrnSallyLake6/23-9/8-t-n=5lDOJrlCL DISSOLVEDOXYGENSATURATION(°/0).l>UIa0~n = 6fn=7-+n= 6+-n =37t---n=15+--n=7n=5-t-n=84---n=7I--n=4--+n=4---+n=3-.+n=3-~.HI-n=5.-+--n=8_In=6-~_t---+In=4--""".1---+1n=5I-(]'I-..jCDID0-NVI00000000II II II----.+-n=3•n=I~VI00l-"--'.cOCneechakoCr.8/6-8/11c-;--iDevilCr.n:l8/22U1::0IOJFogCr.5/5-91120JIC-Po--iTsusenaCr.5/5-9/12::::lO..n:lO:::::~DeodmanCr5/5-9/11cc<::)(rD-<Wo/anaCr=J-;OJ'<OJ(j)515 - 9II9CT............_,Jt.Cl~»rP::lCn:l(j)KosinaCr'""i.ClQJ::l~5/4-9114,+.-----...~'?i)c+C;'~•"'U•..Y::::5r+,__ITIJayCr.r5/5-9/15o11)C(j)~5/29-9/15CTVl-<;U.JayCr.SI.Ij)_I-J.OJCD'.0,-r,-+;u.l-<$CDiU_J.f))GooseCr.5/5-9110<~0{f),~.:JOJ::l'0Oshe/naR."'Ul-t.E.CD1T15/5-9/9....J.O_.J.<o'~,-+OJ•.~::0::(::r-..l0Ul::J-..J.e_::lCD(j)FogCr.06/12-9/12:.::(j)-CUrtCrGrif~;u(j)TsusenaCr.--sn::1<.06119-9/12DOC!..;iDtlodmanCr.~6/19-9/11,--;-<$-".J0..=<--"'""1rPm».......~00..o.Wa/anaCr.6123-91150...~wp;'~KosinaCr.6/27-9/140..'.-+::1(j)\D......J.'f)~U.JoyCr.5/29-9/150).3,:>~~'grc~IenGooseCr.5/14-9/10::lCn~::lrtO.rD~Oshe/naR5/27-9/9'~3O_;l::liD--'.~..:r'..'1(j)IIct·~_;~OJ~•..........JSollyLakert-<;rt<6/23-9/8":Y"InOJrD'00))c~0.. "TlOJ~ct---n=6n=5(Xlon=6n=7n=5n=8-rn=7n::6n;:;38n=15~II_I --I_I-I~-I•1----,• In=4~n=4iJ.• In=8• In=4+--n::3n=3.I•• In=6n=5~1I_.--pH;-..II0-..lII I IUII I In;:;3•n=I(]lUI5/5-9/128/6-S/II8/226/23-9/S6I27-9/14O'Jo5/5-9/115/5-9/20(f)5/4-9/14P~5/5-9/15l)r5/29-9/15zG>5/5-9/l0l)5/5-9/9fll::0g6121-9/12~6/19-9/12<..06/19-9/11CDN6I23- 9IIs'5/29-91155/14-91105/27-9/95/5-9/12DeadmanCr.TsusenaCrDeadmanCr.FogCr.TsusenaCr.(.f)cFogCr.(.f)-lzl>SollyLokeGooseCrOshetnaR.OshetnoR.CheechakoCr.WolanaCr.~Kos/naCr.--jfllJoyCr(f)UJayCr51;0<:WolonoCr.rn.::tJKosmoCr~UJoyCr51-i~GooseCr,-iDevilCr::0rnc--jl>::0-<:£.rt,._.OJ::T,1)(I)rt(l)"OJ(I)0~-;,-.(0-0-8'0C-;(I)<.nIWIU,)"0'-11.,_J._'J(I).:J~:J~til~CDtil0-,l)VI::oOJ.....I.('0OJVI=.J_...,~n:J(1),0~,')n,l)c:r+--.:.:JrD~0..O-.~:3II'D::T~OJrtrtV::T-'.CDOJ,;-'?'()J_..1~-;c+O.,DCOJ'3(I)3v-':::(1)tDC,-OJ0).r:::-J.....I:-;COJo~·OJ~-+,:::::lrt.0~.oO~vr+:::lIVI-.J'1)(!\-;"'1)~-----"'S.....I.<c;--;U-....(1)0c+'PVlI.....I.\_0oI'>.~-~:3.;;VI0,-t.-J-~·O:.;yC(I)~.(I)~.:ltil r-n=5SPECIFICCONDUCTANCE(..umhos/cm)UI0;;;~~~~~t.g;0000000000tI I I I ItI I I I I I I I I 1III-n0~.COC.....,CIle8chokoCr.ro8/6-S/11Ul-tO~vilCr.S/22Iw::0I[DFogCr.Q)5/16-9112=iTSUS8noCr.5/15-9112-:-l-OJ(Dt1-~::r....,<C)(D;;08admonCr.5/16-9/11,1)(0.)JJOJOJ~CL~::::l{/lCC-<WofonoCr.5/17-9117C;0.'n3ilrtrt~crC".....J.cuKosinoCr.en5/13-9/14([).....,0~•}-J.:::jn__en»~ro<,-tJayCr.:iC:5/16-9/J5;,coUl.....1<<-srnu.JoyCr.51."UOrtrtoJ0Jr5/29-9/15!a-::rm~::::len~5/14-9/10Ulrol'lC'n(;00S8Cr.rororo.....,~V><'.0;':.OshefnoR."U5/27-9/9OJCD....1.~rti'\.)c+)-J.:::::Y"(D-rn::l0.....J·n__::0~·o~0(J)Ulro....,cFogCr.a6/21-9112~~0..OJ•rtro~(J)0:>::::[0-0..-lTsusenoCr._6/19-9/12OJ-,.,-\-3Z~6/19-9/11mDOJrol:>08odmonCr......,.~rtD-o~.WofonoCr.N6/23-9/15-+,'0OJ~.0Ul~::0-fDV>CD<KosinoCr.6/27-9/14------J([)------JCLo..~~rnV>rtl::0U.JayCr.51.5/29-9/15ro_I,~•..--0.1.=1(J)GooS8Cr.5/14-9110{/l'8UloC;:)-'0~Osh~fn(lR.5/27- 9 / 7~::::lOJco0..crn(J)-"--"'::3---..I.....J.~CDr+-t,:J('oJ.....J.II-rrtnSallyLo*~6/23-9/S-f-n=3• n = Ijo-------n=6•In=7+-n=6-t-t--n=9I------+-n = 7+-n=6--t-n=4.-+n=4---+-n=4-I--n=4--+-n=4I--n=54-n=84--n=6n=38n=6I.n=5 ~.::;:,+,•.»:5rD:.Z(I)()__.....0•"""'0,,j.,0..._Oro'---t,00...~_•.0 ...0'0VlClJro~ro:;-0...0..Vl,--V1~.~_<DDroill.:):,~VlC.~o::lInill::lp...0...~:30-~:5---...~OJ::-~~'CT~---J.(n:;IT~.IIrojj)~ClJd'~Vl(j)~1.CL..:..:~cIIIIro~,,-.J....__~ClJ~:..0M-e---J.cr:3rt0crr----r~,roroCT}L'1---J.----I_I.C'L'-..0.--1----.J."CO\1>''!-I)NVl.....'"~,,(".-):),TOJ)('0'i)~~-n~.LlC,:0wIUlI'----J~.-__hOJiT>IT_.....IOJ:5C,::l~·ro~VlTURBIDITY(NTU)(.01""(1l.....lD-N(.01VIUi000UI0UI0UI0UI0IIIIIIIIIIIIICheecIJoJoCr8/11I-n=/~DevilCr.-NoDataCollected[DFogCr.5//6-9/12C-iTsusenoCr.5/15-9/12»Cr.:::0Deadman5/16-9/11~Cr.5/17-9/171n = 8WatanaI •enK.Cr.~5"5-9/14-ioSlnarr1JayCr.~5/16-9/15JI•n = 6enU.JayCr.51r5/29-9/15GooseCr.2G)5//4-9//0OshetnaR.5/27-9/91I•n=5\JI'TJen::0cFogCr.a6/21-9/121•n = 4en0-iTsus~noCr.6/19-9/12tn = 4~DeadmanCr.-W6//9-9/11~n=4:::0WatanaCr,~6/23-9/15,n = 4----<KosinoCr.6/27-9/14•In = 4rrJ:::0U.JayCr.SI.~129-9/15•In=5~GooseCr.5/14-9//0I•n=6-irr1OshetnoR.5/27-9/9•In = 5enSollyLake-INoDataCollected DRAFT FIVE/3.0 Percent dissolved oxygen saturation in surface water at all tributary habitat evaluation sites ranged from 77%in Watana Creek to 108%in Fog Creek.Individual site means ranged from 97%recorded at Cheechako Creek to 100%in Tsusena,Deadman,Kosi na,and Goose Creeks and the Oshetna River. Values of pH in all tributary evaluation sites ranged from 6.7 in Watana Creek to 8.1 in Jay Creek.Mean pH values for all sites range from 7.1 in Cheechako Creek to 7.6 in Jay Creek. Observed turbidities,expressed in NTUs,ranged from less than 1 NTU in at least one site on each tributary to 25 NTUs in vJatana Creek.Mean and medi an turbi dity values were hi ghest in vJatana Creek,12 and 8 NTU respectively,and lowest in Goose Creek,1 NTU. Specific conductances,expressed in umhos/cm,were measured in all tributary habitat evaluation sites.Values ranged from 22 umhos/cm ir. Cheechako Creek to 212 umhos/cm in Watana Creek.Lowest mean and median observations occurred in Cheechako Creek,25 and 23 umhos/cm respective- lye Highest mean and median values were observed in Watana Creek,158 and 169 umhos/cm,respectively. 3.1.1.2.1 Continuous Surface Water Temperature Continuous surface water temperatures \,'ere recorded in five selected clearwater tributaries to the Susitna River at sites located immediately DRAFT FIVE/3.a above the respective tr"ibutary mouth from June 19,1982 through October 16,1982.Because of occasional thermograph malfunctions,several gaps in the data occur.Mean monthly temperatures were calculated for all streams for the sampling months,but only those means which were calculated from at least 75%of the total possible observations during the sampling period were compared. Tributary surface water temperature ranged from O°C to 16.5°C during the sampling period.Mean monthly surface water temperatures were lowest in Tsusena Creek in June (6.4°C),July (8.2°C),August (8.4°C),and Septem- ber (5.5°C),and in Kosina Creek in October (O.7°C).Highest mean monthly surface water temperatures occurred in Watana Creek in June (8.7°C),in Goose Creek in July (5.5°C)and August (lO.8°C),in the Oshetna River in September (6.2°C)and in Watana (6.2°C)and Tsusena Creeks (1.2°C)in October (Figure 5-3-8).Daily minimum,maximum and mean values for each stream during the sampling period are graphically presented in Figures 5-3-9 through 5-3-13.A comparison of temperature values among streams is presented in Figure 5-3-8.Tabular continuous surface water temperatures are listed in Volume 4,Part 1,Appendix 4C (ADF&G,1983a). 3.1.1.3 Discharge Discharge measurements on selected tributaries were taken during the months of August and September,1982.Fog,Tsusena,Watana,Jay and Goose Creeks were sampled once during each sampling period,August 12 N....'"'"...."lD'"c:NlD1"IN....'"c:I'"1;;;1601"q1q..Ic:I~0c:I'"NI~NI......NIII~..1<:'";::.....c:'",..,I'"!II14.0-1""I~!I1II~c:lDI~....I-1201I~I I..~Vij<Xl<:'"IitrVff~-U-Iill~~ftY11:~10001lD1w'"a::"1•=>c:...8.0IIII-II!IIIlD<tI....a::-wI..c:a..::E6.0WIIIII-rr~IIIrrl.•...II0...~II:;:I~~1u40-1II:;1..., I:;-I:;-I.J:;-1.J<:I<:I0~!uAi1i«20-1I,-1-,1I~«00• 1z00IIiIiI1 IIIIIIIIIiIA5oIJJASoIJJA SoIJ JASoIJJAS0TSUSENACR.WATANACR.KOSINACR.GOOSECR.OSHETNAR.HABITATEVALUATIONSITESFiSlUre5-3-8~'1onthlythermoqrnphdatasummary,Mean(.),range(I)and25th,50th(median),and75thpprccntiles(-8-),forselectedhahitatevaluationsiteswithintheproposedimpoundmentareafromJunethrouqhOctober,1982(n=thenumberoftwohourintervnlobservationstakeneachmonthat~achsite). 18.0TSUSENACREEK16.0-·_·-MAXIMUMTEMFoERATURE----MEANTEMPERATIJRE-----MINIMUMTEMFoERATURE2.0u14.00~Wa::}.:::>12.0......\«I·a::.,wI .Q.0.'\i\.:::t10.0WI\f1.I'.......Va::\Iw,.1\......e.o\I«~~Iv\yIt.,LJ\I>(\~6.0.r-JIIL.-l\III'It.l.La:::::>(f)4.010/159/309/158/308/15DATE7/307/156/300.0fiiiiiii\I,,»)i6/20Fiqure5-3-qnai1ythermoqraphdatasummaryforTsusenaCreek,RM181.3,GCS32N04E36ADB,June20throughOctober15,1982. 18.0WATANACREEK16.014.0~U0~WIX120='.-q:IXW10.0Cl.~W.-IX8.0w.-«~6.0w0q:u..IX~4.0(J)2.01/..\,..\!i\, ii\,;\~!Iv~".'\'f\".I·i\j'..'j\1f\I \.\.I'J}.'\I.i \,MAXIMUMTEMPERATUREMEANTEMPERATUREMINIMUMTEMPERATURE•10/159/308/300.0I ,,iiiIII6/206/307~157/308715DATEFicjure5-3-10DailythermographdatasummaryforWatanaCreek,RM194.1,GCS32N06E25CCA,June21throughAuqust14,September9throughSeptember18andSeptember28throughOctober15,1982. 18.0KOSINACREEK-·_·-MAXIMUMTEMPERATURE---MEANTEMPERATURE----MINIMUMTEMPERATURE9/157/156/30~\~0.0iiiiiiIi6/202.016.0........140U0-wa:::12.0::>.-«a:::wa...10.0~w.-a:::8.0\W.-«~6.0wIU«LLa:::::>4.0enFiqure5-3-11DailythermnqraphdatasummaryforKosinaCreek,RM206.8,GCS31N08E15BAB,June28throughAugust17andSeptember20throughOctober15,1982. )t18.0GOOSECREEK16.0u14.0oW0::::::>120.....<t0:::Wa..~10.W.....0:::W.....8.0<t~wU60<tlL..0::::::>en4.02.0\\,~y\\t,~\I\I~:-'\,"I."l./\',-.,-'-'-MAXIMUMTEMPERATUREMEANTEMPERATURE----MINIMUMTEMPERATURE10'/159/309/158/308/15DATE,.,-0.01-iiiiiiiI5i6/206/307/157/30Fiqure5-3-1?nil.i1ythermorjrF\PhdatasummaryforGooseCreek,RI'1231.3.GCS30N11E320BC,,lune28throughOctober15,1982. )18.016.0OSHETNARIVERMAXIMUMTEMPERATUREMEANTEMPERATUREMINIMUMTEMPERATURE~14.0u0---W0:::12.0\::)I-\q0:::\~wa.1.,1~W\\l-II,(')V\0:::W80I-q~w6.0UqI.L.0:::::J(f)4.02.010/159/309/158/308/15DATE7/307/156/3000'IIiiIIII6/20FiCjllre5-3-1JDailythermoqraphdatasummaryfortheOshetnaRiverRf1233.4,GC30NllE34CCD,June28throuqhJuly1andJuly9throughSeptember26,1982. DRAFT FIVE/3.0 through August 21,1982 and September 10 through September 19,1982. Discharge on Deadman Creek was measured only during the August sampling period.Frequency of sampl ing on all streams was 1imited because of personnel constraints and difficult sampl ing conditions due to high water. Discharge increased in all streams measured from the August to the September sampling periods.Discharge among streams ranged from 61 cfs in Jay Creek to 330 cfs in Tsusena Creek in August,and from 150 cfs in Goose Creek to 557 cfs in Watana Creek in September.Individual stream discharge measurements are presented in Table 5-3-3. 3.1.2 Resident Fisheries Investigations 3.1.2.1 Arctic Grayling Distribution and Abundance Arctic grayling (Thy~allus arcticus Pallas)were captured at all tributary habitat evaluation locations during the 1982 Aquatic Studies of the proposed impoundment areas. Four thousand three hundred and sixty-seven Arctic grayling over 135 m~ fork length were captured.Table 5-3-4 1 ists the grayl ing catch by location and month.Only hook and line catches are listed as other gear types contributed less than 1%(33)of the total catch. Table 5-3-3.Discharge data on selected tributaries within the impoundment study area,1982. Discharge Tri butarya Oa te (1982)(ft 3/sec) Fog Creek 8/15 269 9/12 307 Tsusena Creek 8/16 330 9/12 363 Deadman Creek 8/21 228 Watana Creek 8/15 229 9/19 557 Jay Creek 8/12 61 9/19 154 Goose Creek 8/19 79 9/10 150 a All discharges were taken in proximity of the mouth with the exception of Deadman Creek where it was taken approximately three miles upstream from the mouth. Vo15/TABLES/PAGE 1 0802087M.Stratton TABL5/Tables/Stratton Table 5-3-4.Arctic grayling hook and line catch by location and month, Proposed Impoundment Areas,1982. Location May June Llul y August September Total Oshetna River 10 288 243 172 113 Goose Creek 38 91 76 2 207 Jay Creek 3 79 130 108 4 324 Kosina Creek 37 232 491 604 320 1684 Watana Creek 128 175 208 36 547 Deadman Creek 1 40 51 110 1 203 TsusenrJ Creek 7 10 29 26 7 79 Fog Creek 1 5 17 '")25(. Totals 58 528 1260 1392 544 3782 Others in Proposed Impoundments 7 4 2 13 Sally lake 3 33 36 a/Om)428 50 25 503A.P.LE.- (5 Creeks) Totals 55 h';lh 1688 1477 569 4334"";v""; a/Above proposed iJT!poundment elevation. Vo15/TABlES/PAGE 2 080208/M.Stratton TABl5/Tables/Stratton Table 5-3-5.Arctic grayling hook and line catch and effort by tributary and month for the mouths of the eight tributarY habitat evaluation location,Proposed Impoundment Areas,1982. location May June July August Sept.Total Catch 6 12 20 6 44 Oshetna Hours 1.5 0.75 1.0 1.5 4.75 River Catch/Hours 4.0 16.0 20.0 4.0 9.3 Catch 12 13 2 a 27 Goose Hours 1.0 1.0 0.75 0.25 3.0 Creek Catch/Hours 12.0 13 .0 ?.7 0.0 9.0 Cn-t:ch 3 17 25 2 a 47 ,Jay Hours 0.5 1.0 1.0 0.25 0.5 3.25 Creek Ca tch/Hours 2.5 17.0 25.0 8.0 0.0 14.5 Catch 21 38 74 54 46 233 Kosina Hours 3.0 2.5 2.5 2.25 5.0 15.25 Creek Catch/Hours 7.0 6.5 29.5 24.0 9.2 15.3 Catch l'/atana Hours Creek Catch/Hours Catch 1 38 11 47 1 98 Deadman Hours 1.0 5.0 0.75 1.75 0.25 8.75 Creek Ca tch/Hou rs 1.0 7.6 14.7 26.9 4.0 11.2 Catch 7 10 29 26 7 79 Tsusena Hours 2.0 5.0 3.0 2.0 1.0 13.0 Creek Ca tc h/Hou rs 3.5 2.0 9.7 13.0 7.0 6.1 Catch 0 0 1 0 0 1 Foq !kurc:.0.5 1.0 0.(5 0.5 0.5 ?75 Creek Catch/Hours 0.0 0.0 4.0 0.0 0.0 0.4 Catch 38 115 165 151 60 529 TOTAL Hour~8.5 15.5 9.25 8.5 9.0 50.75 Catch/Hours 4.5 7.4 17.8 17.8 6.7 10.d Vo15/TABLES/PAGE 3 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-6.Arctic grayling hook and line catch and effort by tributary and month for the eight tributary habitat evaluation locations in their entirety,Proposed Impoundment Areas, 1982. Location May June July August Sept.Tota 1 Catch 10 288 243 172 713 Oshetna Hours 2.5 21.25 22.0 18.25 64.0 River Catch/Hours 4.0 13.60 11.1 9.4 11.1 Catch 38 91 76 2 207 Goose Hours 8.75 6.75 12.75 7.0 35.25 Creek Catch/Hours 4.3 13.5 6.0 0.3 5.9 Catch 3 79 130 108 4 324 <Jay Hours 0.5 10.5 12.0 9.5 2.75 35.25 Creek Catch/Hours 1.5 7.5 10.8 11.4 1.5 9.2 Catch 37 232 491 604 320 1684 Kosina Hours 11.5 28.75 31.5 38.0 52.75 162.5 Creek Ca tch/Hours 3.2 8.1 15.6 15.9 6.1 10.4 Catch 128 175 208 36 547 Watana Hours 18.5 18.0 13.5 16.75 66.75 Creek Catch/Hours 6.9 9.7 15.4 2.2 8.2 Catch 1 40 51 110 1 203 Deadman Hours 1.5 9.0 4.5 11.75 2.25 22.0 Creek Catch/Hou rs 0.7 4.4 11.3 23.1 0.4 9.2 Catch 7 10 29 26 7 79 Tsusena Hours 2.0 5.0 3.0 2.0 1.0 13.0 Creek Ca tc h/Hou rs 3.5 2.0 9.7 13.0 7.0 6.1 Catch 0 1 5 17 2 25 Fog Hours 0.5 3.0 1.25 1.5 2.5 8.75 Creek Catch/Hours 0.0 0.3 4.0 11.3 0.8 /.9 Catch 58 528 1260 1392 544 2782 TOTAL Hours 8.5 83.5 98.25 104.0 103.25 407.5 Catch/Hou rs 4.5 6.3 12.8 13.4 5.3 9.3 ~,Aug.Sept.NSTrlb.CPUE20:!16S10"~6O •.MayJuneJulyAug.Sept..'Trlb.CPUEI2Aug.Sept.MayJuneJuly20;:15e"10"•Q60'c-=1p..?ii'(:,-~'I''..'..~.1t,•,"2015G10010oCJo,JuneJulyAug.Sept.(-MayJuneJulySept.MayJuneJuly20:!15•~10•'r't-'.b51-,'.,, ,0-'•2016~10..,2015"cS10~50',,, ,,, ,,, ,2016CIo10u..'6'j'till'0'0 0,~0lO.0MayJuneJulyAug.Sept.May.kinedulyAug.Sept.Figure5-3-14.ArcticgraylinghookandlineCPUEforthemouthsoftheeighttributaryhabitatevaluationlocations,proposedImpoundmentAreas,1982. CPUE20205'"15c:-~10IIIo5oNSJuneSept.+0+~15IIIGi10~oINSI I II IMayJuneJuly2015CD~10oc:J5oNSMayJuneJulySept.+0+20c:III15E~10CDo5oIC"'JI'I I,-.;.;.,,:y::,MayJuneJuly'-.JuneJulyIII15c:CD~1010to-50', ,In...-,I I , ,!20Aug.Sept.+0+MayJuneJUly20155oI I I , , I ,"WOO,[--::1' ,>.Cll10..,5o0MayJuneJulyAug.Sept.+0+21g10II.+0+-Aug.MayJunoJuly5O.,J ",J , ,IJI I152'"c:;;;10o:lCFigure5-3-15.ArcticgraylinghookandlineCPUEfortheeighttributaryhabitatevaluationlocationsintheirentirety,ProposedImpoundmentAreas,1982. Vo15/TABLES/PAGE 4 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-7.Arctic grayling age-length composition,Proposed Impoundment Areas,1982. Total No.~1ean Ranqe %of Age Fish Sampled Length(mm)(mITt)Sample I 5 147 115 -170 2 II 12 202 170-230 4 III 26 255 220-295 9 IV 55 292 270-335 20 V 88 320 280-345 31 VI 59 344 310-360 21 VII 25 367 345-395 9 VII I 9 393 375-395 3 IX 3 415 410-420 1 ,.-..Total 282 313 115-420 100 --_.-------- 3530\.25>-<.>zUJ~20UJcru.~1525I:ITm17'7nlmWI:IXXAGES(yrs)Figure5-3-16.Arcticgraylingagefrequencycomposition,proposedImpoundmentAreas,1982. Vo15/TABLES/PAGE 5 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-8.Arctic gr?vling length-frequency by tributary,Proposed Impoundment Areas,1982,catch data. Fork Oshetna Goose Jay Kosina Watana Deadman Tsusena Fog Total Length River Creek Creek Creek Creek Creek Creek Creek (mm) less than 200 1/0a /10/0 11/4 12/1 10/1 15/8 3/8 1/4 53/1 200-209 5/1 2/1 6/2 8/1 2/0 3/2 0/0 0/0 26/1 210-219 2/0 1/0 1/0 11/1 2/0 9/5 1/1 O/G 27/1 220-229 10/1 4/1 2/1 27 /2 5/1 9/5 1/1 0/0 58/1 230-239 20/2 2/1 6/2 31/2 11/2 16/8 1/1 0/0 87/2 240-?49 25/3 8/3 12/4 38/2 4/1 13/1 1/1 3/12 104/3 250-259 29/3 8/3 9/3 52/3 11/2 15/8 3/3 2/8 129/3 260-269 36/4 8/3 5/2 56/3 10/2 11/6 2/2 3/9 131/3 270-279 35/4 5/2 18/6 77 /4 15/3 15/8 2/2 0/0 167/4 280-289 56/6 14/5 16/5 102/6 18/3 13/7 2/2 0/0 221/5 290-299 76/9 25/9 12/4 125/7 32/6 14/7 2/2 0/0 286/7 300-309 86/10 29/11 25/8 147/8 33/6 6/3 0/0 2/8 328/8 310-319 111/13 29/11 38/12 202/11 43/8 12/6 9/9 1/4 445/11 320-329 96/11 30/11 34/11 196/11 67/12 18/9 10/10 5/20 456/11 330-339 92/11 27/10 37/12 180/10 67/12 11/6 12/12 1/4 427/10 340/349 63/7 30/11 27/9 172/10 74/14 4/2 12/12 2/8 384/9 350-359 41/5 22/8 21/7 123/7 53/10 4/2 15/15 0/0 279/7 360-369 44/5 16/6 12/4 92/5 29/5 5/3 11/11 0/0 209/5 370-379 19/2 9/3 5/2 58/3 20/4 2/1 5/5 3/12 121/3 380-389 7/1 6/2 6/2 29/2 23/4 1/0 4/4 1/4 77 /2 390-399 17/2 1/0 4/1 17/1 10/2 0/0 4/4 1/4 54/1 over400 8/1 0/0 ?/1 10/1 6/1 1/0 2/2 C/O ?g/1 n=879 276 309 1765 545 197 102 25 4098 mear=315 320 317 319 332 271 311 1 322 320 range=190-420 200-395 140-420 175-420 120-420 130-400 180-410 175-395 120-420 a/Catch data (numbers/percer.t) mean :315 n:4098 C III III E 10... (l) 200 220 240 260 280 300 320 340 ·380 380·400 Length(mm) Figure 5-3-17.Arctic grayling length frequency composition for all tributaries combined, Proposed Impoundment Areas,1982. 420 420 400 420 KOSINA n=1765 OSHETNA n=874 GOOSE n=276 JAY n=306 340 360 380 "I;0) 0.._~ I·i<),....,- 220 240 260 2BO 300 320 16 14 tl2z l&J10~ ~8 a:: u.6 ~0 4 2 0 16 14 t 12z ~IO a l&J 8 0:: U. 6 ~0 4 2 0 16 14>- ~12 l&J ~IO 0l&J a::B u. ~6 4 2 0 200 16 >-14 (.) z 12l&J ~IO l&J ~8 ~6 4 2 0 300 320 420 Length Figure 5-3-18.Arctic grayling length frequency composition by tributary, Proposed Impoundment Areas,1982. i..: 16 c III III I e It)>-C'lu/2 (I)z ILl :::>1O Watan-a 0 ILl 0::8 n=545. I&. :J!6 0 4 14 >-12 (.) ~10 :::>a ILl 0:: I&. ~ ~I CD E Deadman n=197 Fog n=25 n=102 Tsusena 260 2 14 >-12 u::z:1OILl :::> 0 8ILl a:: I&.6 :J!40 2 °2 0 220 240 14 t >-I c ~I IIIUCD~IO E :::>CX) 0 0 ILl (') a:: I&. :J!0 Figure 5-3-18.(continued). I 40 I 350 300 -E E 25-.c-C) c: Q) -I 200 150 I-range 10 I .~mean Age Figure 5-3-19.Arctic grayli~g age-length relationship for all tributaries combined,Proposed Impoundment Areas,1982. -------~--_._,_."... 'j4OCHOshetna..!..400Goose400jJay-......-..-350~••-350"'T350--•---••-•_300300......::!:300-•-IE---E250•E250E250......--EoS.r;....-...200:S200.r;2UV1......Q....C01CD.4>150c150c:150"1•-IQ)4>--I-I1001001005~i50-f50010iI IititIiii iIIiiIioI234567890I2:34 567890I2345678 9AGE(yrs)AGE(yrs),AGE(yrs)".~,~400-1Kosina.....WatanaDeadmana:400'l:.--.!.---350-350-..-••-..---•300-__300.-•3-•_.-------•E250•~250E•-E--E•----:S200-5200....~200••...Q-CDCDc150;150c150-.Q).4>•-I-I;-110010010050505002345678 90i23456t890I2:3456789AGE(yrs)I \AGE(yrs)AGE(yrs)Figure5-3-20.Arcticgraylingage-lengthdistribution,ProposedImpoundmentAreas,1982. 420 • •X • x -E ci'meanE-,•.e-Lmean_'_a xc310-Q) ..J 300 • X 290 280 27 X 260 • 250 240 230 220 170 • n=:257 .=>males X¢females JZIlI IX][:III i F ~~1m "Age (yrs) Figure 5-3-21.Arctic grayling age-length relationship,males vs females, Proposed Impoundment Areas,1982. ------_.-------_._...._--------- DRAFT FIVE/3.0 The total habitat evaluation location catch was 3782 Arctic grayling in 408 angler hours,giving a catch rate of 9.3 Arctic grayling per angler hour for the entire summer study.Arctic grayling catches,angler hours and catch rates are listed in Tables 5-3-5 and 5-3-6 and illustrated in Figures 5-3-14 and 5-3-15.Arctic grayling catch per hour ranged from a low of 0.0 to a high of 29.6. Age,Length,Sex Two hundred and eighty-two Arctic grayling taken by hook and line were aged by scale analysis.These fish ranged from Age I to Age IX.Age V Arctic grayling were dominant,comprising 31%of the total sample (Table 5-3-7 and Figure 5-3-16). Lengths VJere taken from all Arctic grayling sampled.Lengths ranged from 120 mm to 420 mm,VJith the 310 mm to 329 mm Arctic grayling occur- ring most frequently (22%)(Table 5-3-8 and Figures 5-3-17 and 5-3-18). The age-length relationship shown in Figure 5-3-19 is calculated from the ages and lengths taken from a subsample of 282 Arctic grayling. Age-length comparisons between the tributaries themselves and against the overall combined sample were also made.No apparent differences Viere found (Figure 5-3-20).From the same subsample,an age-length comparison of males versus females was calculated (Figure 5-3-21). Other than the 17 mm difference in mean lengths (males 328 mm versus females 311 mm)no other differences were apparent. MAYJUNEJULYAUG.SEPT.TOTAL2637311829141-male2530331618122-female1.041.230.941.131.611.16-male/female150140130120110100z90§C"80~702-60!I(I)50~40302010o4035J::..~30u.....25o~20L~15femeles___,::JzI~J,,malesioiiMAYJUNEJULYAUGSEPT.rna1esfemalesTOTALFigures5-3-22.Arcticgraylingsexcompositionbymonth,ProposedImpoundmentAreas,1982. n=IO Jl. 320 n=9 y. 310 300 TI[ El 280 420 n=16 IX 410 400 n=[53901ZIII "WI 380-WE370E-or:mean 1ZII-Cl 360c CI) -' mean 350 1lI 1ZI 340 non-spawning males spawning males Sex non-spawning spawning females females Sex Figure 5-3-23.Arctic grayling length vs.sexual maturity relationship by sex,Proposed Impoundment Areas,1982. __________0_.__..--. 0:3316 slope =-.043 survival rate,~95.8%Jmm or 40.5'l6Jyr x xxx x x x 400 "0 G) Q.eas 0en x '"...40G) .Q E 30~ Z 0:184 x 0 slope =-.942 survival rate :.39.2%Jyr. 3 o III IV v Age VI VII VIII IX __Figure 5-3-24.Arctic grayling instantaneous survival rate curves,Proposed Imoundment Areas,1982. '/c Vo15/TABLES/PAGE 6 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-9.Arctic grayling tagged by location and month,Proposed Impoundment Areas,1982. Location May June July August September Total Oshetna River 0 0 275 233 154 662 Goose Creek 0 34 87 76 1 198 Jay Creek 0 53 123 105 4 285 Kosina Creek 16 207 479 589 300 1591 \~atana Creek 1 103 163 205 36 508 Deadman Creek 0 33 45 102 1 181 Tsusena Creek 0 10 28 26 2 66 Fog Creek 0 1 5 17 2 25 Others \~i th in Impoundment 4 4 0 2 0 10 Sallv Lake 0 3 0 31 0 34 Total 21 448 1205 1386 500 3560 APTE ~ (5 creeks, 1 mile each)0 0 382 50 24 456 Total 21 448 1587 1436 52.1 4016 a/Above proposed impoundment elevetions. 1'1 DRAFT FIVE/3.0 Two hundred sixty-three Arctic grayling were sampled for sex composi- tion.Males comprised 53.6%of the sample and the overall ratio of males to females was 1.2 males:1 female (Figure 5-3-22). During the upstream spawning migration,50 Arctic grayling were necropsied for sex determination and sexual maturity;26 males and 24 fema 1es.All males 330 mlTl and over and females 320 ITIm and over were found to be sexually mature,while inversely,all males under 330 mm and females under 320 mm were found to be nons pawners or sexually immature. No overl ap occurred when 1engths of spawni ng versus nonspawni ng fi sh were compared.However,age classes of spawning fish did overlap.Both Age IV and V grayling were found sexually mature and immature depending on their length (Figure 5-3-23). The instantaneous survival rate was calculated by two methods,using age versus catch and length versus catch.the resulting rates were very similar,being 39.2%and 40.5%,respectively (Figure 5-3-24). Tagging/Recapture (Migration) Four thousand sixteen Arctic grayling were tagged during 1982 studies, 3,560 within the proposed impoundment areas and 456 in selected tribu- tary streams above the proposed impoundment elevation (Table 5-3-9).Of these 4,016 tagged Arctic grayling,320 (8%)were subsequently re- captured within the same stream where they were tagged.The majority (67%)were recaptured at their initial point of tagging from 1-100 days later.Movement both upstream and downstream followed the expected ---------~------,~.~._-_.----,--,------ Vo15/TABLES/PAGE 7 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-10.Arctic grayling intrastream movement by tributary and month as demonstrated by recoveries of 1982 tagged fish, Proposed Impoundment Areas,1982. -----_.-_~_-_..~.- Vo15/TABLES/PAGE 8 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-11.Arctic grayling interstream movement by location as demonstrated by recoveries of 1982 tagged fish, Proposed Impoundment Areas,1982. Re-Total Tagging Tagging Date Days at Recovery covery Miles Location TRM Tag No.Tagged Large Location TRM Moved Oshetna R.1.7 11727 9/9 2 Kosina Cr.1.9 30.2 Goose Cr.0.0 007405 6/18 102 Kosina Cr.0.0 24.5 Goose Cr.0.0 007408 6/18 38 Kosina Cr.0.1 24.6 Jay Cr.Slough 007021 5/29 86 Kosina Cr.2.6 4.4 Jay Cr.Slough 007023 5/29 123 Watana Cr.8.5 23.0 Jay Cr.0.0 007478 6/24 34 Watana Cr.4.3 18.7 Jay Cr.3.0 009405 7/27 49 Kosina Cr.0.0 4.7 Jay Cr.2.1 009438 7/27 49 Kosina Cr.0.6 4.4 Kosina Cr.0.0 04852 6/23 34 Jay Cr.0.0 1.7 Kosina Cr.2.0 009162 7/24 3 Jay Cr.0.8 4.5 ~'Jatana Cr.8.5 009656 7/28 44 Tsusena Cr.1.5 22.8 Watana Cr.0.4 007414 6/28 49 Tsusena Cr.0.1 13.3 Deadman Cr.0.0 007061 6/19 29 Tsusena Cr.0.0 5.4 Deadman Cr.0.0 007067 6/19 85 Fog Cr.0.4 10.4 Deadman Cr.0.3 007437 7/18 28 Tsusena Cr.0.1 5.8 Vo15/TABLES/PAGE 9 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-12.Arctic grayling interstream movement by location as demonstrated by recoveries of 1981 tagged fish during 1982, Proposed Impoundment Areas,1982. Tagging Recapture Numbers Location to Location Recaptured Oshetna River Oshetna River 65 Goose Creek Goose Creek 36 / Goose Creek Jay Creek 5 ~ Goose Creek Oshetna River 1 a/Goose Creek Kosina Creek 1 - Jay Creek Jay Creek 36 / Jay Creek Goose Creek 3 ~ Jay Creek Kosina Creek 8 Jay Creek \~a tana Creek 1 a/Jay Creek Tyone Lake 1 - Kosina Creek Kosina Creek 124 Kosina Creek Deadman Creek 5 a/Kosina Creek Goose Creek 1 - Kosina Creek Watana Creek 1 Kosina Creek Kosina Slough 1 Kosina Slough Kosina Slough 1 Kosina Slough Kosina Creek 3 Kosina Slough Watana Creek 1 Deadman Creek Deadman Creek 7 Deadman Creek Kosina Creek 1 Deadman Creek Fog Creek 1 Deadman Creek Oshetna River 1 ~/ Deadman Creek Tsusena Creek 1 Tsusena Creek Tsusena Creek 20 a/Tsusena Creek Oshetna River 1 - Tsusena Creek Jay Slough 1 Tsusena Creek Kosina Creek 2 Tsusena Creek vJatana Creek 1 Fog Creek Fog Creek 3 Fog Creek Goose Creek 1~ 350 308 returned to same stream 42 changed streams a/through Vee Canyon DRAFT FIVE/3.0 pattern with most of the upstream movement occurring in early summer and the downstream movement occurring in the early fall (Table 5-3-10). Fifteen Arcti c grayl i ng were recaptured withi n tributary streams other than the stream where they were originally tagged,two moving to another stream up the Susitna River and 13 to another stream down the Susitna. These fish were at large from 2-123 days and moved from 1.7-30.2 miles with averages of 50 days and 13.2 miles (Table 5-3-11). Of the 2,619 Arctic grayling tagged during 1981 studies,350 (13.4%) were recaptured during 1982 studies.Three hundred and eight (88%)of these fi sh returned to thei r ori gi na 1 taggi ng stream.Forty-two (12%) of the 1981 tagged grayling recaptured were found in streams other than those in which they were tagged,25 moving to another stream down the Susitna and 17 moving to another stream up the Susitna (Table 5-3-12). One Arctic grayling tagged on June 21,1981 in Jay Creek (RM 208.5)was recaptured by a sportfisherman on June 22,1982 in Salt Creek,a small tributary to Tyone Lake.This represents an upstream movement of approximately 75 miles in one year. Population Estimates Population estimates based on data collected in July and August were calculated for each of the eight tributary habitat evaluation locations. Recapture information indicates that grayling movement is at a minimum duri ng these months;1,205 grayl i ng were tagged and only 2 of the 185 Vo15/TABLES/PAGE 10 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-13.Arctic grayling population estimates by tributary habitat evaluation location,Proposed Impoundment Areas,1982. Population ~Confidence !V Grayling/Grayling/ Location Estimate Interval Mile Acre Oshetna River 2426 1483-4085 1103 56 Goose Creek 949 509-1943 791 90 Jay Creek 1592 903-3071 455 101 Kosina Creek 5544 3792-8543 1232 69 C:,~"' Watana Creek 3925 1880-6973 324 44 Deadman Creek ~/734 394-1502 1835 273 Tsusena Creek '1/1000 743-1530 Fog Creek !Y 176 115-369 440 Totals 16,346 9,819-28,016 664 ~correction factor included. E./95%. c/Includes only that part of Deadman Creek below falls '1/1981 estimates. Vo15/TABLES/PAGE 11 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-14.Data used for Arctic grayling population estimates, Proposed Impoundment Areas,1982. No. No.No. Marked Recaptured Caught Stream Reach July (M)August (R)August (C) Oshetna River Pools 82 15 115 Riffl es 184 16 108 Mouth 7 1 20 Goose Creek all 87 8 74 Jay Creek all 123 10 108 Kosina Creek Pools 209 32 337 Riffl es 195 24 213 Mouth 73 13 82 Watana Creek East Fork 28 6 58 West Fork 73 13 82 Middle Section 61 8 68 Deadman Creek all 45 8 110 Tsusena Creek all 28 1 26 Fog Creek all 5 0 17 Vo15/TABLES/PAGE 12 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-15.Arctic grayling population estimates by age class, Proposed Impoundment Areas,1982. No.No. Recaptured Caught No.Marked in in in %August August Age Length (mm)July (M)R/M (R)(C)N I (1 ess than 175)5 0 2 3.3 1955 II (176-231)86 3 82 III (232-278)226 4.4 10 222 4602 IV (279-307 )263 8.8 23 263 2904 V (308-331)321 13.7 44 342 2454 VI (332-356)204 23.5 48 270 1134 VII (357 -377)81 19.8 16 107 521 VII I (378-399)27 7 41 25.7 180 IX (more than 400)8 2 8 13 ,750 Totals 1221 153 1337 10,617 total each aqe estimate 13,750 =1.2951 correction factor'-=total estimate 10,617 '1.'7 DRAFT FIVE/3.0 recaptured had moved out of their original habitat evaluation location by August. The population estimates provided in Table 5-3-13 are for the eight tributary habitat evaluation locations in their entirety,with the exception of Deadman Creek where only the section studied below the falls is included.Insufficient data were obtained at Tsusena and Fog Creeks during 1982,so the 1981 population estimates have been used. (Actual data used for population estimates is listed in Table 5-3-14). Population estimates range from a low of 176 Arctic grayling in the Fog Creek habitat evaluation location to a high of 5,544 Arctic grayling in the Kosina Creek habitat evaluation location,with a total estimate of 16,346 for the eight tributary habitat evaluation locations combined. Estimates of numbers of Arctic grayling per mile range from a low of 324 in Watana Creek to a high of 1,232 in Kosina Creek,with an average of 664 for the 24.5 miles of tributary waters to be impounded.Densities ranged from 44 to 273 Arctic grayling per acre of stream. Population estimates were also calculated for each age class present in the sample.The capture/recapture probability for Arctic grayling Age IV and less was found to be significantly lower than for the older fish, Age V-IX (Table 5-3-15).A correction factor of 1.2951 was calculated based on the ratio of the sum of the population estimates for each age class versus the population estimate for all age classes combined. \' ------_._-------,......··,'''-".._.•--'0--·.__- DRAFT FIVE/3.0 Spawning The first Arctic grayling were observed at the mouths of tributaries on May 13,but none were observed upstream until May 26.Surveys were not comprehensive,but spawning Arctic grayling were found in four locations;three pools at TRM 1.4,1.2 and 0.1 on Kosina Creek,and one pool at TRM 2.1 on the Oshetna River.Characteristics of these pools were similar,including low water velocity,three to six foot depth,and a large area of small (sand to 111 gravel)substrate.Arctic grayling were also observed at this time in the tributaries below these pools, but none were found further upstream. Juveniles Juvenile Arctic grayling were observed in all of the eight tributaries sampled,both above and below the proposed impoundment elevation. Scattered i ndi vi dua 1s and small schools (1 ess than 25)were observed along the banks of the tributaries in side channels,backwater areas, pool edges and small sloughs.Characteristics of these areas were low water velocity,shallow (less than one foot)depth and abundant cover consisting of large rocks and vegetation.Large concentrations of juveniles were found early in the summer at tributary mouths and throughout the summer in clear water sloughs off the mainstem Susitna River just above and below Jay Creek at RM 208.7 and 208.1 and below Watana Creek at RM 193.9.These sloughs generally have springs as their source and periodically are completely cut off from the Susitna. DRAFT FIVE/3.0 3.1.2.2 Dolly Varden Dolly Varden were found to be more widely distributed in the proposed impoundment areas than past studies have shown,with observations being made in Cheechako,Devil,Watana,Jay and upper Deadman Creeks.Habitat occupied by Dolly Varden in these streams varied significantly from that occupied by Arctic grayling,with most observations occurring in IIplunge poolll type habitats. A total of 16 Dolly Varden were captured.All were of the resident stunted or dwarf variety with lengths ranging from 120 mm to 205 mm {Plate 5-3-4}. 3.2 Mainstem Habitat and Fisheries Investigations 3.2.1 Aquatic Habitat Investigations Aquatic habitat investigations during 1982 on the mainstem Susitna River within the proposed impoundment study area were limited to obtaining general water quality data at designated sites,mapping the general habitat characteristics at selected habitat evaluation sites,and identifying slough habitats within the study area.Aerial surveys were conducted on the entire mainstem study reach to generally evaluate the habitat characteristics of this area.Time and personnel constraints, and study priorities did not permit a more in depth assessment of this habitat during 1982. II,III!i...i)'}Dolly DRAFT FIVE/3.0 3.2.1.1 General Characteristics of Mainstem Study Area The mainstem Susitna River habitat evaluation location consists of the reach of the Susitna River within the impoundment study area (RM 152 to RM 239).The Devil Canyon section extends for 32 miles from the Devil Canyon dam site (RM 152.0)to the Watana dam site (RM 184.0).This reach of the river has a gradient of approximately 18 feet/mile.The Watana study section extends for 55 miles from the Watana dam site (RM 184.0)to a point approximately five miles above the confluence of the Oshetna and Susitna Rivers (RM 239.0).The gradient in this reach is approximately 13 feet/mile.Due partly to the lower gradient of the stream channel this reach is not as confined as in the Devil Canyon section and often splits into two or more channels.Streamflow velocities are generally lower than those in the Devil Canyon reach. The seven mainstem sites where fish sampling was conducted were mapped to show the general characteristics of these sites.These maps are presented in Appendix Figures 5-D-2 to 5-D-8.No other aquatic habitat data was collected at these sites. 3.2.1.2 Water Quality Instantaneous water qual ity and air temperature data for all mainstem and slough sites are presented in Appendix Tables 5-C-18 to 5-C-27. Graphical representations of the range,mean and median values for each water quality parameter for each habitat evaluation site are presented in Figures 5-3-2 to 5-3-7. -------,--------_._-,.....~--_._.~--_._--........_._------------,------- DRAFT FIVE/3.0 The lowest instantaneous surface water temperature recorded in the Susitna River was O.l°C above Goose Creek on May 14,1982,while the highest temperature of 13.6°C was observed above Jay Creek Slough on June 24,1982.Mean and median instantaneous surface water temperatures ranged from 7.1°C and 7.9°C respectively above Goose Creek to 9.9°C and 11.1°C respectively above the Oshetna River. Ma instem instantaneous di ssol ved oxygen concentrati ons ranged from 9.0 mg/l above Fog Creek on August 15,1982 to 13.5 mg/l above Goose Creek on May 14,1982.Dissolved oxygen mean values for individual sites varied from 10.3 mg/l above Fog Creek to 11.2 mg/l above Goose Creek. Median dissolved oxygen values ranged from 10.3 mg/l above Tsusena Creek to 10.7 mg/l above Fog Creek and Deadman Creek. Percent dissolved oxygen saturation values at Susitna River evaluation sites varied from 83%above Fog Creek to 105%above Goose and Watana Creeks.Mean dissolved oxygen saturation values ranged from 90%above Fog Creek to 100%above Watana Creek.Medi an values ranged from 92% above Fog Creek to 100%above Kos ina Creek and the Oshetna Ri ver. Overall mean and median percent dissolved oxygen saturation values for the Susitna River are 97%and 98%respectively. Observed pH values ranged from 6.6 above Goose Creek to 8.1 above Deadman Creek.Individual mean values ranged from 7.2 above Fog Creek and Goose Creek to 7.6 above Deadman Creek.Median Susitna River pH values ranged from 7.2 above Fog Creek to 7.6 above the Oshetna River. DRAFT FIVE/3.0 Turbidities for the mainstem varied considerably over the course of the sampling period and among sampling sites.Observed turbidities varied from 14 NTUs above Goose Creek on May 14,1982 to 150 NTUs recorded above Watana Creek on August 16,1982 and Tsusena Creek on July 26, 1982.Mean values ranged from 53 NTU above Fog Creek to 100 NTUs above Watana Creek.Median turbidity values varied from 51 NTU above Fog Creek to 110 NTUs above the Oshetna River. Specific conductance observations at all mainstem Susitna River eval- uation sites ranged from 73 umhos/cm above Tsusena Creek to 144 umhos/cm above Oshetna River.Mean specific conductance values ranged from 104 umhos above Fog Creek to 127 umhos/cm above Jay Creek Slough.Specific conductance median values varied from 101 umhos/cm above Fog Creek to 126 umhos/cm above Deadman Creek. 3.2.1.3 Discharge Daily USGS provisional discharge data for the mainstem Susitna River at gaging station No.15291500 near Cantwell (USGS,1982)was used to construct a corresponding Susitna River hydrograph (Figure 5-3-25). During the open water field season,minimum discharge,14,000 cfs, occurred on May 1,1982,while maximum discharge,24,100 cfs,occurred on June 21,1982.Mean discharge for this period was 12,400 cfs. ~'-'\24222018<316oo)(14enll-l)12w(,!)10a::oct::x:l)8eno642)PROVISIONALUSGS1982DISCHARGEDATAoIIii,IIiiIi5/155/306/156/307/1571308/158/309/159/30DATEFigure5-3-25SusitnaRiverhydrographatVeeCanyon,RM223.3(USGSgagingstationNo.15291500),fromMay1throughSeptember30,1982(USGS,1982). DRAFT FIVE/3.0 3.2.1.4 Mainstem Slough Habitats Aquatic habitat investigations during the 1982 field season in the proposed impoundment areas have identified four major mainstem slough areas.These four areas are referred to as Watana Creek Slough (RM 193.5),Kosina Creek Slough (RM 205.6),Lower Jay Creek Slough (R~1 208.1),and Upper Jay Creek Slough (RM 208.7).All are adjacent to the mainstem Susitna River.Limited water quality data was collected only at Upper and Lower Jay Creek sloughs and is presented in Appendix Tables 5-C-23 and 5-C-24. In addition to the slough areas identified in the field,six additional areas which may classify as mainstem slough habitats were identified from color aerial photos (scale 111 =2000 1 )of the proposed impoundment areas.Four of these sites are located 3-4 miles below the mouth of Fog Creek;one site is located approximately five miles below the mouth of Kosina Creek;and the last site is located approximately three miles above the mouth of Jay Creek.These slough habitats have not been verified by ground surveys at present. 3.2.2 Resident Fisheries Investigations 3.2.2.1 Burbot Distribution and Abundance Burbot (Lota lota L.)were captured at all of the seven mainstem habitat sites.One hundred and eighty-five trotline sampling days produced a Vo15/TABLES/PAGE 13 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-16.Burbot catch and catch per trotline day by mainstem site and month,Proposed Impoundment Areas,1982. Mainstem Catch (numbers/(catch per trotline day) Site May June July August September Total 1 ·--.--3/(0.8)6/(1.5)7/(1.8)16(1.3) 2 --.--.3/(0.8)1/(0.3)0/(0.0)4/(0.3) 3 ·8/(2.0)3/(0.8).--.--111(1.4) 3A --.----.--6/(1.5)7/(1.8)13/(1.6) 4 ·5/(1.3)10/(2.5)7/(1.8)2/(0.5)24/(1.5) 5 ·4/(1.0)2/(0.5)4/(1.0)2/(0.5)12/(0.8) Watana Creek Mouth 7/(3.5)17/(0.6)9/(0.3)13/(0.4)9/(0.4)55/(0.5) ,,,...-..Total 7/(3.5)34/(0.8)30/0.6)37/(0.7)27/(0.6)135/(0.7) 91 xIXVIIIVII Age VIIV 15 1 Figure 5-3-26.Burbot age-frequency composition,Proposed Impoundment Areas,1982. >-. (J.-c Q) ::J 0' Q) '- LL ~ 1 mean ~438 n =135 cca CD E co (I).. O..L..-...... <30-0'-a~6~376 ':h6 -"476"'628 '-678~:-6-26'-676 726 Length(mm): Figure 5-3-27.Burbot length frequency composition,Proposed Impoundment Areas,1982. Vo15/TABLES/PAGE 14 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-17.Burbot age,length and sex frequency,P~oposed Impoundment Areas,1982. Total No.Mean Range of r~a 1es Females Age Fish Sampled Length(mm)Lengths No./%No./% IV 10 361 330-385 6/60 4/40 V 27 388 290-445 12/44 15/56 VI 14 444 340-540 7/50 7/50 VII 7 471 420-575 3/43 4/57 VIrI 4 611 55-670 2/50 2/50 XI 0 X 1 675 1/100 0/0 Total 63 424 290-670 31/49 32/51 jl!)O &:.-CD C CD ..J I - 260,;"r,----r---,..--'"T""--~---"---"'--_---- IV V VI VII VIII Age IX X Figure 5-3-28.Burbot age-length relationship,Proposed Impoundment Areas, 1982.(.=mean,I =range) I 0 I .c-Cl C CD ..J • x • • • x x x • •males x females 25()-L---.,.....-._,......-_--......--~-._,_-.....--- IV V VI VII VIII Age· IX x Figure 5-3-29.Burbot age-length relationship,males vs.females,Proposed Impoundment Areas,1982. Vo15/TABLES/PAGE 15 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-18.Burbot tagged by mainstem site and month,Proposed Impoundment Areas,1982. Mainstem Catch Site ~1ay June July August Sept.Total 1 3 5(1)3 11 2 1 1 0 2 3 3 2 5 3A 5 3 8 4 1 8 2 0 11 5 3 4 1 2 10 Watana Creek 1 6 2(1)9(1)4 22 Mouth Total 1 13 20 23 12 69 ( )number of recaptures \03 DRAFT FIVE/3.0 total catch of 135 burbot.Burbot catches per trotline day ranged from 0.6 to 3.5 with the mean being 0.7.Table 5-3-16 lists the burbot catch and catch rates by mainstem site and month. Age,Length,Sex A subsample of 63 burbot were aged by otolith analysis.These fish ranged from age IV to age X.Age V was the dominant age class,compris- ing 43%of the sample (Figure 5-3-26). Lengths were taken from all burbot captured.Lengths ranged from 178 mm to 740 mm with the 350 mm to 450 mm burbot occurri ng most frequently (59%).The mean and median lengths were 438 mm and 415 mm respectively (Figure 5-3-27). Of the sixty-three burbot that were examined for sex determination;31 were males and 32 were females (Table 5-3-17).The age-length relation- ships shown in Figures 5-3-28 and 5-3-29 are calculated for the entire subsample and as a comparison between males and females. Tagging/Recapture Sixty-nine burbot were tagged at mainstem sites during 1982 studies,the majority at the Watana Creek site (Table 5-3-18).Three of these burbot were recaptured from 27-42 days 1ater at thei r ori gi na 1 poi nt of tag- ging.Of the 23 burbot tagged during 1981 studies,four were recaptured during 1982 studies.All were at large from 11-13 months and were captured at their original point of tagging . -----~_._.._,.-_.__._,.....,.,.._--_.__._--- Vo15/TABLES/PAGE 16 080208/M.Stratton TABL5/Tables/Stratton Table 5-3-19.Longnose sucker catches by mainstem site and month,Porposed Impoundment Areas,1982. Mainstem Catch Site May June July August Sept.Total 1 0 0 0 0 2 0 0 0 0 3 0 0 0 3A 2 0 2 4 0 0 7 0 7 5 0 0 4 0 4 Watana Creek 11 12 21 3 6 53 Mouth TOTAL 11 12 21 16 6 66,- /OS" mean=395n=5810(I)~CIII•E<.200 210230260:210290'310330360·370H30'O"410'430460470490LengthFigure5-3-30.Longnosesuckerlengthfrequencycomposition,ProposedImpoundmentAreas,1982.....\)>-s·0c:Q):)0'Q)'-lL1~ DRAFT FIVE/3.0 3.2.2.2 Longnose Sucker Distribution and Abundance Longnose suckers (Catostomus catostomus Forster)were captured at four of the seven mainstem habitat sites.All of the 66 suckers were captured by gillnets.The majority (53)were taken at the ~'Jatana Creek site.Longnose sucker catches by month and site are given in Table 5-3-19. Age,Length,Sex Lengths were taken from 58 longnose suckers.These lengths ranged from 210 mm to 495 mm \'Ii th the 410 mm to 429 mm suckers occurri ng most frequently (31%)(Figure 5-3-30). Due to the limited sample size,no age or sex determinations were made. Spawning Longnose suckers in spawning condition were captured at the Watana Creek mainstem site during May and early June.By late June,all suckers sampled had already spawned. \0'1 DRAFT FIVE/3.0 Tagging/Recapture Fifty longnose suckers were tagged during 1982 studies,the majority (41)at the Watana Creek mainstem site.Two of these fish were subse- quently recaptured at their original point of tagging. Of the 97 suckers tagged during 1981 studies,two were recaptured in 1982.Both were captured at their original point of tagging. 3.2.2.3 Other Species In additi on to burbot and longnose suckers,three other speci es of resident fish were captured by gillnets at mainstem sites,including 21 Arctic grayling,five round whitefish (Prosopium cylindraceum Pallas) and one humpback whitefish (Coregonus pidschian).The grayling were captured throughout the summer at the Watana Creek mainstem site only. The single humpback whitefish was captured in July at RM 208.1.The five round whitefish were captured at the Watana Creek mainstem site in July and August and were all sexually mature and in a prespawning condition. 3.3 Lake Habitat and Fisheries Investigations 3.3.1 Aquatic Habitat Investigations Due to limited time and personnel,lake sampling efforts during 1982 were limited to Sally lake,the largest lake within the proposed im- ,-----------------....,."._--_._--------- DRAFT FIVE/3.0 poundment boundaries.Morphometric date for Sally Lake is presented in Table 5-3-20.A contour map of the lake is presented in Figure 5-3-31. Depth area and depth volume curves are presented in Figures 5-3-32 and 5-3-33 respectively. 3.3.1.1 General Characteristics of Sally Lake Sally Lake,a clear,oligotrophic tundra lake,is situated on a plateau approximately two miles east of the mouth of Watana Creek at an ele- vation of 2025 feet {Plate 5-3-5}.The lake is irregular in shape with a total surface area of 63 acres and a maximum depth of 27 feet.It appears to be spring-fed as there are no streams of significant size entering it.The lake drains from the north end into a stream which empties into Watana Creek approximately two miles away.The entire lake would be inundated by the proposed Watana Reservoir. The lake can be divided into two geomorphologically distinct areas.The southern end of the lake {approximately 20 acres}is a shallow bowl shaped basin with average depths of four feet.This is an area of relatively high littoral productivity and is characterized by extensive growths of submerged aquatic vegetation.Some emergent macrophytes are present near the shoreline areas.The northern section of the lake, approximately 40 acres,is in a deep V-shaped basin which slopes steeply from the shoreline resulting in a poorly developed littoral zone.Water depths toward the middle of this section are in excess of twenty feet. Submerged aquatic vegetation grows sporadically throughout the shallower depths of this area.Emergent macrophytes are limited to the littoral areas. \0" Table 5-3-20.Sally Lake morphometric data,1982. Morphometric Parameter Surface area Volume Maximum depth Mean depth Shoreline length Maximum length/orientation,main axis Maximum width/orientation \\0 Estimate 63 acres 736 acre-feet 27.0 feet 11.6 feet 10,450 feet 3,100 feet/NW-SE 950 feet/NE-SW DEPTH CONTOUR:FEET SHORELINE CONTOUR LIN ES a 400 SALLY LAKE MORPHOMETRIC MAP AUGUST 18and 19,1982 Geographic Code:S32N07E29 Water Surface Area =63 Acres Lake Volume =736 Acre·Feet ALASKA DEPT OF FISH AND GAME S'J HYDRO AQUA TIC STUDIES PROGRAM Figure 5-3-31 Sally Lake.morphometric map.GC S32N07E29. Hi 1020SURFACEAREA(acres)30405060oIIIIIII748----~::12........:::I:I-~1602024o10203040506010BOPERCENTSURFACEAREA90100Figure5-3-32Hypsographic(depth-area)curveofSallyLake,GCS32N07E29,(August,1982). o100200VOLUME(ocre-feet)30040011008007008004812~---CICI..-~:::t:I-16a..WCl202428o102030401108070PERCENTVOLUME8090Figure5-3-33Depth-volumecurveofSallyLake,GCS32N07E29(August,1982). OJ ~ 1'0 -J >,..-..- 1'0 V") 4-o 3 OJ..... > 1'0..... !>- OJ« L!'l I M I L!'l OJ ~ rt:l..-c.. DRAFT FIVE/3.0 3.3.1.2 Water Quality General water quality data were collected on a monthly basis at a site located at the west end of the lake.These data are presented in Appendix Table 5-C-28.Ranges of individual parameters are presented in Figures 5-3-2 through 5-3-7. 3.3.2 Resident Fisheries Investigations 3.3.2.1 Lake Trout Thirty-two lake trout (Salvelinus namaycush Walbaum)were captured by hook and line,hoop nets and gillnets at Sally Lake.Lengths ranged from 260 mm to 490 mm with the mean bei ng 419 mm.No age or sex determinations were made with this limited sample size. Due to the high incidence of mortality associated with even the most mi nima 1 handl i ng,only 20 of these 1ake trout were tagged •.One tagged 1ake trout was subsequently recaptured,however thi s di d not provi de enough data to allow a viable population estimate. 3.3.2.2 Arctic Grayling Forty-two Arctic grayling were captured by hook and line and hoop nets at Sally Lake.Lengths ranged from 220 mm to 325 mm with the mean being 263 mm.No age or sex determinations were made with this limited sample size. 1/5 DRAFT FIVE/3.0 Thi rty-five grayl i ng were tagged of whi ch two were subsequently re- captured.No population estimate was made due to the insufficient recapture data. "Iv DRAFT FIVE/4.0 4.DISCUSSION 4.1 Tributary Habitat and Fisheries Investigations 4.1.1 Water Quality 4.1.1.1 Instantaneous Water Quality Ranges of water qual ity parameters monitored in tributaries in the proposed impoundment areas during 1982 are comparable to values observed during the 1981 season (ADF&G 1982b).With the exception of turbidity levels,no major differences are apparent in the range of water quality parameters among tributary sampling sites.Preliminary water quality data collected above the PIE of selected tributaries indicates that there is no significant difference in water quality above and below the PI E. Of the water quality parameters which were monitored,only turbidity appeared that it might influence the distribution and abundance of fish among tributaries.Turbidity levels in most tributaries remained relatively low during the open water season.Arctic grayling were found throughout these clearwater habitats and were generally not found in the turbid water of the mainstem Susitna River.Other fish species such as sucker,burbot and whitefish,which are present in most turbid water areas were not found to reside in the clearwater tributaries.These preferences in habitat may be associated with differences in turbidity levels between mainstem and tributary habitats. ---_.~_._--~. ~'~"_'.__..~."-~_._'---~--~-~'~~---~~---"<"'~' .- DRAFT FIVE/4.0 Relatively high turbidity levels were recorded in the lower reaches of Watana Creek during most of the sampling season.These turbid water conditions,resulting from melting permafrost in upstream areas,reduced the effectiveness of hook and 1i ne samp 1i ng for Arct ic grayl i ng.The low catch rates associated with these turbid water conditions resulted in the suspension of grayling sampling efforts in this area.These low catch rates may be attributed to the ineffectiveness of the sampl ing technique or a reduced population of grayling due to the turbid water environment. 4.1.1.2 Continuous Surface Water Temperatures Lowest mean monthly surface water temperatures during most of the 1982 open water field season occurred in Tsusena Creek.These low tempera- tures,combined with the general infertility of the water may partially explain why fewer fish were captured from this stream during the field season.Low surface water temperatures may reduce catch per unit effort and may also be a contributing factor for the seemingly low populations of grayling in this stream. As expected,the degree of fluctuation in diel and seasonal water temperatures was found to be partially dependent upon volume and depth of water among individual streams.In streams with low discharge,such as Goose Creek,diel and seasonal surface water temperature fluctuations are relatively large when compared with the buffered temperature pat- terns of a larger volume,deeper stream such as the Oshetna River. Stream surface water temperatures in the study area may also be "g -_.._------.._.__._---------- DRAFT FIVE/4.0 significantly affected by contr'ibuting lakes,glaciers,residual snowpacks,local precipitation and topography. 4.1.2 Discharge The hydrograph of the Susitna River at RM 233 (Figure 5-3-25)indicates that the Susitna River discharge was declining when low discharge levels were recorded at tributary sites during August.Dry ground conditions prevailed throughout the impoundment areas during the August sampl ing period,resulting in inconsequential runoff from the 1ight,infrequent precipitation that occurred during this time.Tributary discharges taken during this period are therefore considered to be good estimates of the August base flows of these streams. The mean discharge for the Susitna River for August 1982 was determined to be 66%of the mean,historical August discharge for the years 1962 through 1972 and 1980 through 1982,inclusive (USGS 1978,1980,1981 in press,and 1982 provisional data in press).Therefore,tributary discharges measured in August,1982,may be much lower than the histor- ical August mean discharge for these tributaries. September stream discharge levels increased in all tributaries over levels recorded during the August sampling period.Percent increase of discharge ranged from 110%in Fog Creek to 253%in Watana Creek.The variable degree of percent increase among streams measured is due to the timing of individual stream sampling during the period (Table 5-3-3)and differential stream runoff resulting from the local ized precipitation \\9 DRAFT FIVEj4.0 falling within the impoundment areas (R&M Consultants,1982).General- ly,September stream discharges taken later in the sampling period had a hi gher percent increase over thei r August di scha rge measurements than those taken earlier in September.This was mainly due to increased precipitation over the duration of the September sampling period and an increased proportion of the precipitation reaching the stream as runoff as the ground became saturated. The fluctuations at the Susitna River hydrograph during the period which parallels the September tributary discharge sampling period corresponds to the increase of the September tributary measurements over the August measurements.The large percent increase in stream discharges recorded in Goose,Jay and Watana Creeks,were taken at a corresponding peak or on a rising arm of the Susitna River hydrograph,while small discharge increases recorded in Fog and Tsusena Creeks were taken at a corresponding low point. Low discharge levels,such as those recorded in August,contribute to hook and line sampling success for Arctic grayling by:1)increasing the proportion of stream accessible to sampling;2)concentrating fish in a reduced number of deeper areas;3)decreasing overall stream velocities;and 4)in some cases,reducing stream turbidities.However, the poor sampling efficiency of hook and line techniques for the younger age cl ass grayl i ng,precl ude the accurate assessment of the abundance and distribution of these age classes.Therefore,it is unknown if the decrease in utilizable habitat resulting from decreased discharge, combined with the territorial nature of the Arctic grayl ing (Vascotto DRAFT FIVE/4.0 and Morrow,1973),cause displacement of the smaller,less territorial grayling during these periods.Younger.age class grayling displaced into submarginal habitat during low flow periods,may be more suscep- tible to disease and predation,possibly affecting year class strength. Preliminary data indicates that the Susitna River hydrograph near Cantwell combined with precipitation data of the impoundment areas,can be used to determine relative changes in tributary discharge.Stage discharge relationships on tributaries should be evaluated in the future to more accurately define the relationship of these streams to the mainstem Susitna river and to estimate their individual contribution to the proposed Devil Canyon and Watana Reservoirs. 4.1.3 Effects of Gradient on Stream Habitat General habitat evaluations of tributaries within the impoundment study area indicates that stream gradient is the most important topographical feature affecting the lotic habitats.Stream characteristics,including channel morphology,water velocities and substrate type are directly influenced by stream gradient.High gradient streams in the impoundment study areas generally have larger substrates,more narrow and shallow stream channels,higher water velocities and are more likely to contain fish passage barriers than low gradient streams. An evaluation of the gradient of individual streams indicates that there is relatively little change in gradient between the reach of stream below the PIE and a five mile reach immediately above the PIE on most 1","1 .....~.",."._._.._-_..._----,_._----- DRAFT FIVE/4.0 streams within the impoundment study area.Accordingly,the habitat of these individual tributary reaches is also similar except for obvious habitat differences due to changes in gradient which occur within Deadman and Kosina Creek above and below the PIE. The greatest difference in stream gradient above and below the PIE, along with the greatest change in habitat,occurs in Deadman Creek.The stream abruptly changes from a meandering,low gradient (62 feet/mile), relatively slow flowing,wide,deep stream with many pools above the PIE to a high gradient (253 feet/mile)stream characterized by high velocity whitewater areas with·very few pool areas below the PIE.The low gradient section above the PIE supports some of the largest grayling in the impoundment study area,while the habitat below is more suited for the smaller,younger age classes of grayling. Kosina Creek,unlike Deadman Creek,has no abrupt change in stream gradient but does have substantial habitat differences in the stream reaches above and below the PIE due to an inconspicuous change in gradient pattern.The section of Kosina Creek from five miles above the PIE downstream to the PIE is characterized by a constant increase in stream gradi ent resulti ng ina uni form riffl e type habitat interspersed with a few shallow pools.The contrasting,step-like,decreasing stream gradient below the PIE to the mouth results in an alternating pool /riffle pattern of habitat types.Large deep pools are formed in the low gradient sections while riffle areas dominate,the higher gradient reaches.This diversity in the habitat below the PIE probably provides the best overall grayling habitat within the impoundment study area. ---------------,-,.- DRAFT FIVE/4.0 Impoundment pool elevation,stream gradient below the PIE and tributary mouth elevation will determine the extent to which an individual stream will be inundated by the proposed reservoirs.Since pool levels of the proposed Devil Canyon and Watana impoundments will annually vary 105 and 28 feet respectively,a drawdown zone of varying size will occur around the perimeter of each reservoir. This area will be in a constant state of flux between flooding and dewatering depending upon the reservoir water level.The length of a tributary stream affected by the drawdown zone will depend on the depth of the drawdown and the tributary reach gradient within the elevation limits of the drawdown.Affected tributary lengths within the proposed Watana impoundment will be longer than those in the proposed Devil Canyon reservoi r because of deeper drawdowns and the lower overall stream gradients of tributaries associated with the proposed Watana impoundment. Grayling eggs spawned within this drawdown zone in early springs,when reservoir pool levels are rising,may be adversely affected by the flooding of this habitat.Conversely,whitefish and burbot eggs spawned during the autumn and winter months of the year may be dessicated due to receding reservoir water levels during this period. 4.1.4 Barriers to Fish Migration Exi sti ng waterfalls withi n the proposed impoundment study area whi ch constitute a barrier to upstream fish migration have been identified in I :t3 ..._-----------_._--- DRAFT FIVE/4.0 the steeper,more narrow sections of Cheechako,Chinook,Devil,Tsusena and Deadman Creeks.Areas where possible barriers may occur due to high stream velocities have been identified on Cheechako,Chinook,Fog, Watana and Jay creeks.These stream velocity barriers may be temporary or permanent depending on discharge. The only complete barrier to upstream fish migration identified below the PIE is the approximately 100 foot waterfall located on Deadman Creek at TRM 0.6.The proposed Watana impoundment would permanently inundate the falls and allow fish migration between the upper areas of Deadman Creek,Deadman Lake and the Susitna River.A population of relatively large grayling presently exists in the reach of Deadman Creek immediate- ly above the falls.If fish from the Susitna River gain access to the habitat above the falls it may have an adverse effect on the large grayling above the falls due to increased competition.This could result in a gradual reduction of the age class structure and size of grayling in this area. High waterfalls exist above the PIE on Tsusena and Devil creeks at TRM 2.1 and 3.1 respectively.These falls will not be inundated by the proposed Devil Canyon impoundment therefore limiting the amount of stream habitat available to Susitna River fish utilizing the lower reaches of these streams.The 1ength of free-fl owi ng stream habitat which would be accessible to Susitna River fish will be reduced 71 and 13 percent on Tsusena and Devil creeks respectively.This would leave 0.6 and 2.7 miles of stream accessible to Susitna River fish on Devil and Tsusena creeks respectively.Aerial surveys on Devil Creek revealed ....._----------------- DRAFT FIVE/4.0 that fish species,probably Arctic grayling,are present above the fa 11 s.It is not known if fi sh are present above the fall s on Tsusena Creek. Prel"iminary aerial surveys of Cheechako and Chinook creeks indicate that several possible fish migration barriers may exist in the steep,exten- sive whitewater reaches of each stream above and below the PIE.Al- though some of these barriers would be inundated by the proposed Devil Canyon impoundment,several barriers to fish passage may still exist immediately above the PIE on each stream.It was not determined if fish a re present in the upper reaches of these streams.Therefore,the affects of the inundation of these barriers on the resident fish popu- lations are not known. Possible fish migration velocity barriers in Fog Creek are restricted to the turbulent,whitewater areas located within a steep,narrow canyon one to two mil es above the PI E.It is not known if fi sh in the lower reach of this stream have access to the habitat above this canyon. Although grayling and Dolly Varden have been found above the canyon in the Fog Lakes system,these fish are probably part of a resident lake popul ati on and thei r presence above the canyon does not necessari ly indicate that Susitna River fish are able to migrate above the canyon. A small waterfall located approximately one mile up the east fork of Watana Creek may be a periodic fish passage barrier depending upon discharge.Grayling were found above this falls during the summer when discharge was relatively low.However,the falls appeared to be a DRAFT FIVE/4.0 barrier to upstream fish migration at this time.It is possible that these fish may be permanent residents in the area above the falls or they may have ascended the falls during a period when discharge would permit upstream migration beyond the falls. A deep,narrow canyon immediately above the PIE on Jay Creek may inhibit upstream movement of fish during periods of high stream velocities resulting from high discharge.This condition was evidenced by ADF&G personnel during 1981 when no fish were observed in this area.However, adult grayl ing were sighted above this canyon during this years study indicating that the canyon is not a permanent barrier to all fish. Si nce there are no apparent overwi nteri ng habitat areas for grayl i ng within the Jay Creek basin,these sightings indicate that the apparent velocity barriers in the canyon identified in 1981 are not permanent and that Susitna River fish at least have periodic access to the reach of stream above the canyon. No other apparent barriers to fish migration were identified on those portions of tributaries in the proposed impoundment study areas which were surveyed during the 1982 season. 4.1.5 Salmon Spawning Habitat Cheechako and Chinook creeks,located within lower Devil Canyon are the only two tributaries within the proposed impoundment areas that are presently known to be utilized by spawning salmon.Studies conducted by ADF&G during 1981 and 1982 indicate that salmon do not have access to "....-.... DRAFT FIVE/4.0 areas above Devil Canyon (ADF&G 1981b,1983b).The constricting river channel of Devil Canyon apparently creates velocity barriers to salmon which inhibit further upstream migration of these fish.Salmon in the Susitna River have presently been documented as far upstream as RM 157.0. The best salmon spawning habitat on either of these streams was located in the clearwater plume of Cheechako Creek which extended downstream of its mouth into the Susitna River.This area,approximately 60 feet long and 10 feet wide,provided excellent,although limited salmon spawning habitat.Substrate consisted mainly of gravel,and streamflow veloc- ities were moderate.Limited numbers of king salmon utilized this habitat for spawning during late summer. Preliminary surveys on Cheechako and Chinook creeks indicate that salmon util ize only a small portion of the habitat above the mouth.Most of the lower reach on each of these streams is characterized by turbulent, high velocity whitewater areas and spawning habitat appears to be limited.Access to upper reaches of the stream is limited due to fish passage barriers which result from the steep gradients in this area. Additional information on salmon utilizing these streams is presented in the ADF&G Adult Anadromous Report (1983b). During construction of the Watana Dam at RM 184.0,river velocities in the Devi 1 Canyon area are expected to decrease suffi ci ently to allow salmon to migrate upstream of Devil Canyon (Acres 1982).Adult salmon p..'7 DRAFT FIVE/4.0 wi 11 subsequently have access to Devi 1,Fog and Tsusena Creeks.Of these three streams,Fog Creek has the greatest potential for providing new salmon spawning habitat.The Fog Lakes system may support a large number of sockeye and coho salmon fry if adults are able to gain access into this area.Salmon spawning habitat on Tsusena and Devil Creek is more 1imited. 4.1.6 Arctic Grayling Population Estimates During the course of the 1982 Aquatic Studies,biases and assumptions related to the population estimates of Arctic grayling were identified. These biases fall into two general categories,those caused by behavior or other attributes of the biology of the fish and those caused by the sampling technique.Table 5-4-1 lists the major biases. The major bias associated with the behavior and biology of Arctic grayling,and probably the largest bias in the population estimate,is heterogeneity,the variance in individual capture probab"i1ities.The smaller fish (less than 230 mm)have a much smaller probability of capture than the larger fish.One reason for this is that hook and line methods are more selective for the larger fish.Another closely related reason is an aspect of Arctic grayling behavior,strong territoriality. The largest and strongest fish occupy the most advantageous positions at the head of the pool while the smaller fish are pushed farther downstream to the extreme foot of the pool or even out of the pool (r~orrow,1980).Our observati ons confi rm thi sand,additi ona lly,have found that the larger grayling in each area are caught first,raising DRAFT FIVE/4.0 the probab"ility of recapture for larger fish even more.This bias tends to greatly underestimate the population estimates for the smaller age classes.Therefore,by stratifying our data as to age class,a relative correction factor based on this bias can be calculated and applied to the population estimates,as the age class structures of the eight tributaries is similar.This alleviates most of the bias for age classes with a sufficient sample size.A method to sample all segments of the population sufficiently to assign probabilities of capture and recapture to the age cl asses under Age IV wi 11 be requi red if thi s portion of the population is to be included in the overall estimates. Table 5-4-1. Bias: "C"CiITection: Assumption: Bias: Correction: Assumption: Bias: "C"CiITe ct ion: Assumption: Bias: Correction: Assumption: Biases,corrections and assumptions which affect the 1982 arctic grayling population estimates,Proposed Impoundment Areas,1982. Lack of randomness of mark or recapture effort. Stratification of habitat location by habitat type. Random mark and recapture effort. Unequal recapture probability due to time between censusing. Use of single census estimator. Time does not affect recapture probability. Population is open geographically. Use of July and August data only;period of minimal movement. Population is closed geographically. Heterogeneity;variance in,the probability of capture and recapture between age classes. Stratification by age class for entire population, develop correction factor for populations. Population estimates limited to Age IV and older fish due only to insufficient sample sizes of smaller fish. DRAFT FIVE/4.0 One of the sampling technique biases concerns time between censusing. Varying envi ronmenta 1 factors such as temperature,turbi dity and flows may alter the probabilities of recapture.By using a single census estimator as opposed to a multiple census estimator,these variances can be reduced.Minimal variations in flow and turbidity were encountered during censusing in July and August and temperatures were similar,all being in the normal summer range.No differences in capture probability versus temperatures in the normal range have been observed. Time also affects the degree to which the Arctic grayling population is open or closed geographically.Tag return data shows maximum movement, both within and between streams,occurs during May and June as Arctic grayling are entering the tributaries and in September when they are out migrating.By using data from July and August,the period of minimal movement,this bias is also greatly reduced. Another of the sampling technique biases is lack of randomness of mark and recapture effort whi ch affects the probabi 1i ty of recapture.More effort was expended in areas suspected of harboring high densities of Arctic grayling (pool habitat)as opposed to areas suspected of harbor- ing few fish (riffle habitat).This tends to raise the recapture probabilJty in the pool habitat which in turn lowers the total popula- tion est.imate of pools and inversely,lowers the recapture probability in the riffle habitat,which raises the total population estimate. Therefore,by stratifying the habitat location into pool and riffle habitat types,the amount of this bias is reduced.However,some bias DRAFT FIVE/4.0 may still occur between strata due to non-random differences in sampling effort. Sampling problems associated with the individual tributary habitat locations which bias the population estimates are discussed on a stream by stream basis along with the estimates generated and their relative accuracy. 1.'3 I DRAFT FIVE/4.0 Oshetna River The Oshetna River,one of the two largest tributaries in the proposed impoundment areas,presented sampling problems due to its size. Stratification of the river into pool and riffle habitat types allowed all seven of the pools (all located along the east bank)to be sampled in their entirety.Sampling was conducted from both banks,however,due to the width (100-125 feet)of the stream,sampling of the entire riffle reaches was not possible. The relatively low gradient (41 feet/mile)and the presence of numerous boulders in midstream allow for abundant areas of util izable habitat that are outside hook and line effective sampling range.The average depth of 3-5 feet combined with the higher flows in the riffle reaches also reduces hook and line effectiveness.For these reasons,the population estimate generated for the riffle reaches reflect the abso- lute minimum,which in turn means the total population estimate for the Oshetna River should be regarded as being substantially low. Population estimates for the 2.2 miles of the Oshetna River to be impounded are: Arctic grayling population estimate =2426 95%Confidence interval =1483-4085 Arctic grayling/mile =1103 Arctic grayling/acre =56 (pools =1759,riffles =36) DRAFT FIVE/4.0 Goose Creek Goose Creek,one of the small er streams in the proposed impoundment areas,presented few sampling problems.With a width of 30-50 feet and an average depth of 2-3 feet,the entire stream could be sampled effec- tively from either bank.High velocities in some riffle reach~s, associated with Goose Creeks relatively steep gradient (114 feet/mile), slightly lowered sampling efficiency,but for the majority of the stream this was not a problem.No stratification of the stream into pool and riffle habitat types was deemed necessary as clear delineation between the two types was impossible.Since the entire stream was of a similar habitat type,index points were chosen and data was kept for the reaches between these points.Catches and catch rates confirm that Arctic grayling population were similar between the index reaches.For these reasons,population estimates generated for Goose Creek should be regarded as accurate. Population estimates for the 1.2 miles of Goose Creek to be impounded are: Arctic grayling population estimate =949 95%Confidence interval =509-1943 Arctic grayling/mile =791 Arctic grayling/acre =90 133 DRAFT FIVE/4.0 Jay Creek Jay Creek,the smallest stream studied in the proposed impoundment areas,also presented few sampling problems.With a width of 30-50 feet and average depths of 2-3 feet,the entire stream could be effectively sampled from either bank.A gradient of 143 feet/mile and the resultant hi gher velocity lowered the effi ci ency in samp 1i ng some of the pocket water habitat.Extreme fluctuations in turbidity,common in this stream,also lowered sampling efficiency.No stratification by habitat types could be accomplished as even minimal fluctuations in discharge would alter an areas classification.Index points were chosen and data was kept for the reaches between these points.Catches and catch rates were comparable between the index reaches.For these reasons,popu- lation estimates generated for Jay Creek should be regarded as being slightly low. Popu1ation estimates for the 3.5 miles of Jay Creek to be impounded are: Arctic grayling population estimate =1592 95%Confidence interval =903-3071 Arctic grayling/mile =455 Arctic gray1ing/acre =101 DRAFT FIVE/4.0 Kosina Creek Kosina Creek,one of the two largest tributaries in the proposed im- poundment areas,presented numerous sampling problems.With an average width of 125-150 feet,much of the stream could not be sampled.Average depths of 3-6 feet and high flows associated with a relatively steep gradient (114 feet/mile)combined to further lower our sampling effec- tiveness.Sampling could only be conducted from the west bank as much of the east bank is sheer rock cliffs.The stream is also braided with numerous large islands and sidechannels.Stratification by pool and riffle habitat type was deemed necessary and easily accomplished.Pool areas are easily distinguished from riffle areas in this stream based on flow and area.The pools are extremely large,in some cases reaching completely across the stream channel.Effective sampling of the entire pool area was not always possible.For these reasons,the population estimate generated for both the riffle and pool areas of Kosina Creek should be regarded as being the absolute minimum,with the correct estimate possibly being many factors higher. Population estimates for the 4.5 miles of Kosina Creek to be impounded are: Arctic grayling population estimate =5544 95%Confidence interval =3792-8543 Arctic grayling/mile =1232 Arctic grayling/acre =69 (pools =2985,riffles =28, mouth =770) DRAFT FIVE/4.0 Watana Creek Watana Creek,the stream with the longest reach to be inundated by the proposed impoundment (11.9 miles),presented sampling problems associ- ated with this length.As it was not feasible to sample this entire reach,visual surveys were conducted and based on width,depth,pool- /riffle ratios and turbidity,three distinct habitat reaches were identified:from the mouth upstream to the forks,the East Fork and the West Fork.By sampling representative sections of each habitat reach, the corresponding population estimate generated could be extrapolated to the entire reach.Limited sampling conducted outside the study areas produced comparable catches and catch rates. Widths ranging from 40-60 feet and depths from 2-4 feet allow effective sampling from both banks.The East Fork and the reach of Watana Creek below the Forks has the unique characteristic of daily turbidity fluctu- ations caused by areas of thawing permafrost resulting in very unstable soil conditions.As the day progresses,rising turbidity levels greatly reduce sampling effectiveness.Velocities have little effect on sam- pling effectiveness as Watana Creek has a low gradient (60 feet/mile) and velocities are relatively low. For these reasons,the population estimate generated for the West Fork (2.1 miles,low turbidity)should be regarded as accurate,while the East Fork and the reach below the Forks (9.8 miles,high turbidity) should be regarded as being quite low.Therefore,Watana Creeks total population estimate should be regarded as being quite low. 13~ .-._.._------- DRAFT FIVE/4.0 Population estimates for the 11.9 miles of Watana Creek to be inundated are: Arctic grayling population estimates =3925 (Below forks =2615,Westfork =994,East fork =316) 95%Confidence interval =1880-6973 Arctic grayling/mile =324 Arctic grayling/acre =44 ----------_.--_.. DRAFT FIVE/4.0 Deadman Creek Deadman Creek,an average sized stream relative to the other streams in the proposed impoundment areas,presented sampling problems due to its size and gradient.Thick underbrush and rock cliffs on the west bank allowed sampling from the east bank only.With an average width of 60-80 feet and depth of 3-6 feet,the entire stream cannot be effective- ly sampled from one bank.Extremely high velocities and turbulent water conditions,the result of the steep gradient (253 feet/mile),also limits hook and line effectiveness.The Arctic grayling are limited to one large pool and scattered pocket water areas.Also,during August, the majority of our catch (approximately 90%)was of small Arctic grayling (less than 275 mm)that were not present in the stream in these numbers during July.Recapture information from 1981 and 1982 indicate a significant amount of migration both into and out of Deadman Creek occurs throughout the summer.For this reason,the population estimate generated for Deadman Creek should be regarded as being high. Population estimates for the 0.3 mile study area on Deadman Creek below the fa 11 s are: Arctic grayling population estimates =734 95%Confidence interval =394-1502 Arctic grayling/mile =1835 Arctic grayling/acre =273 DRAFT FIVE/4.0 Tsusena Creek Tsusena Creek,another average sized stream relative to the other streams in the proposed impoundment areas,presented few sampling problems.Although excellent habitat is present within the 0.4 miles of stream to be impounded,few Arctic grayling utilize this area.Almost all of the Arctic grayling are found at the mouth and in the extensive clearwater plume extending down the Susitna River.Both of these areas can be sampled effectively in their entirety.This year,with the low discharges,the plume was greatly reduced in size and depth and few fish were captured.With only one recapture occurring,a population estimate could not be generated. /39 DRAFT FIVE/4.0 Fog Creek Fog Creek,another average sized stream in the proposed impoundment areas,presented few sampling problems.With an average width of 50-70 feet and depth of 2-3 feet,the stream could be effectively sampled from either bank.The entire reach sampled contained no large pools and is basically one long riffle.Very little Arctic grayling habitat is present which is reflected by the total summer catch of 25 Arctic grayling.With this small of a sample,a population estimate could not be generated. /t../0 DRAFT FIVE/4.0 The 1982 total population estimate for Arctic grayling in the 24.6 miles of tributary streams to be impounded is 1.6 times higher than the 1981 estimate (16,346 vs.10,279).Although,the 1981 estimate gave a good preliminary indication of the relative abundance of Arctic grayling,the estimate itself contained many of the biases previously discussed which have been eliminated from the 1982 estimate. The 1982 estimates generally encompass a larger area of each stream and more effort than the 1981 estimates.For exampl e,in 1981,the fi rst mile of Kosina Creek was sampled in its entirety and the upper 3.5 miles was sampled only at selected sites.The population estimate generated by this data (2,787)was applied to the entire 4.5 miles.In 1982,the entire 4.5 miles was sampled and the population estimate of 5,544 reflects this increased effort.For this reason,many of the 1982 estimates are higher than the 1981 estimates. In 1981,large concentrations of grayl ing were found at the mouths of Goose,Deadman,and Tsusena Creeks,where the high water levels of the Susitna and the tributaries created large areas of prime habitat.The low water levels encountered in 1981 reduced and,at times,completely eliminated this habitat,resulting in lower catches and lower estimates. Table 5-4-2 compares the 1981 and 1982 total population estimates and estimates by stream. /'-!/ DRAFT FIVE/4.0 Table 5-4-2.Arctic grayling population estimates,1981 versus 1982, Proposed Impoundment Areas,1982. Tributary 1981 1982 Oshetna 2017 2426 Goose 1327 949 Jay 1089 1592 Kosina 2787 5544 Watana 3925 Deadman 979 734 Tsusena 1000 Fog 176 Total Estimate 10,279 16,346 The values generated for population estimates (numbers/mile)are reflec- tive of the relative abundance of Arctic grayling in the stream and can be used in this sense as a relative comparison between streams.They do not take into account the surface area of the stream and,therefore, cannot be used alone to compare the streams.Examination of the density of fish expressed as numbers per unit area of streambed available may provide an indication of habitat quality and availability.For example, the Arctic grayling/mile values generated for Kosina and Jay Creeks of 1,232/mile and 455/mile,respectively,can be compared as to the rela- tive abundance of Arcti c grayl i ng in the two streams.Thi s does not take into account the fact that the average width of Kosina Creek is four times larger than Jay Creek (146 feet vs.37 feet).Therefore, when the surface area is taken into account,the density of Arctic grayling in Jay Creek is 1.5 times that of Kosina (101/acre vs. 69/acre).Although Kosina Creek has the large pools with excellent DRAFT FIVE/4.0 habitat,this lower density is indicative of the large reaches of poor habitat in the riffles.Inversely,Jay Creek does not have the large pools that Kosina Creek has but instead has a larger proportion of bank cover and "edge"conditions which contribute to this larger density. 4.1.7 Spawning and Juveniles In 1982,the majority of spawning occurred during late May and early June,about two weeks later than in 1981.This corresponds with a two week difference in breakup which reflects that water temperatures and spring flooding may be key factors in initiating Arctic grayling spawn- ing.Spent and spawning grayling were captured in streams where water temperatures ranged from 2.3°C to 5.8°C.This coincides with the findings of Tack (1973)and Alt (1976)who feel that temperatures around 4°C trigger Arctic grayling spawning in interior and western Alaska. Observations of the violent nature of ice-out in 1982 in these tributaries indicate that it is very doubtful that Arctic grayling enter the streams and spawn before ice-out. Newly hatched Arctic grayling (20-30 mm)were first observed in mid June and were found both above and below the proposed impoundment elevation. Although no Arctic grayling were observed above the proposed impoundment elevation while spawning was occurring,the presence of newly hatched fish in these areas would tend to confirm that spawning does take place there. DRAFT FIVE/4.0 Small schools (less than 25)of young of the year Arctic grayling were observed in the tributaries throughout the summer,from the mouth to the upstream 1imit of our studies.They frequently occupi ed areas of low water velocity with abundant cover.Large concentrations of both newly hatched and young of the year Arctic grayling were observed in mainstem slough areas immediately below the mouth of Jay,Kosina and Watana Creeks.The presence of young of the year Arctic grayl ing can be attributed to the fact that the sloughs are all spring fed and are excellent rearing habitat.These sloughs are generally sidechannels of the Susitna River during May and early June.Although spawning may occur here,the presence of newly hatched Arctic grayling may be because juvenile Arctic grayling are helpless in water currents for two weeks after hatchi ng (Nelson,1954)and probably have been washed down from the tributaries. 4.1.8 Arctic Grayling Migration Through analysis of tagging/recapture data,it appears that the majority of Arctic grayl ing return to the same stream year after year,in many cases returning to the same specific area within the stream.A small but significant number (12%of the 1982 recaptures of 1981 tagged fish) have been found to migrate to the other streams within the impoundment areas.This migration seems to be random in direction as similar numbers of fish migrate to other streams both up and down the Susitna River. -------,-----,----- DRAFT FIVEj4.0 Interstream movement of Arctic grayling during the 1982 sampling season differs from that found between years with the predominant direction of movement (90%of the recaptured fish)being down the Susitna River.The majority of these fish were recaptured at the mouths of other tributary streams,so the total extent of this movement may be even larger. The reasons for these interstream movements are not known at this time. Territorial displacement may be a major factor,suggesting that the population is limited by available summer habitat.Continued sampling for recaptures both within and outside the proposed impoundment areas will help determine the actual extent of these movements. Intrastream migration is generally a seasonal event.After spawning in late May,a large number of Arctic grayling move up the tributaries to their summer habitat.During mid-summer,movement of Arctic grayling is at a minimum with the majority of the fish being sedentary.Finally,an outmi grati on of Arcti c grayl i ng begi ns in 1ate-August or September. This migration was observed earliest in the smaller streams.Extremes of physical factors (i .e.,late breakup,discharge,temperatures)may alter this basic time schedule,but the pattern of mainstem to tributary and intrastream movement has remained the same. DRAFT FIVE/4.0 4.2 Mainstem Habitat and Fisheries Investigations 4.2.1 Water Quality Ranges of water quality parameters monitored at Susitna River mainstem sampling sites during 1982 are comparable to values observed during the 1981 season (ADF&G 1982b).No major differences are apparent in the range of water quality parameters among the various sampling sites. Of the water quality parameters monitored,only turbidity appeared that it might influence the distribution and abundance of fish species in the mainstem.High turbidity values in the mainstem during the warmer months may selectively exclude some fish species such as Arctic grayling which prefer to reside in the clear water tributaries.However,it is generally assumed that grayling utilize the mainstem habitat for over- wintering when turbidity levels have decreased significantly. 4.2.2 Mainstem Slough Habitats Mainstem slough habitats in the proposed impoundment areas are relative- ly small compared to sloughs in the lower Susitna River.They generally flow clear except during periods of high water when they are affected by the turbid flow of the Susitna River.Water quality data collected at slough sites was limited to Upper and Lower Jay Creek Slough.These data show that conductivity levels are significantly higher in these slough habitats compared to levels in the mainstem or tributaries (Appendix 5C,Tables 1-27). DRAFT FIVE/4.0 These four mainstem sloughs appear to be the preferred habitat of resident juvenile fish in the area.Juvenile Arctic grayling,sucker, and whitefish have been found to utilize these sloughs during the summer months.Burbot have also been found in some slough habitats on occa- sion.Few adult fish have been observed in these slough habitats. 4.2.3 Resident Fish Species One element of the 1981 Plan of Study for the mainstem habitat location was to identify and determine the relative abundance of the fish species that inhabit the mainstem Susitna River at the tributary mouths.In 1982,the allocation of a riverboat to the impoundment studies greatly increased sampling mobility.An attempt was made to document the relative abundance of species which utilize those areas of the Susitna River not affected by the tributaries.This was accomplished by select- ing mainstem sites away from the tributary mouths and utilizing trot- lines and gillnets.Five species of fish were captured including burbot,longnose sucker,arctic grayling,round whitefish and humpback whitefish. Burbot could be captured at almost any point along the banks of the Susitna River.The major limiting factor was water velocity,with the burbot preferring the low velocity areas associated with back eddies and side channels.Limited recapture information tend to confirm findings of Morrow (l980)that these fish generally are sedentary and do not migrate during the summer months. /'-17 DRAFT FIVE/4.0 Longnose suckers were captured in the mainstem Susitna River at large pools and at the mouths of tributary streams.While mature adults were caught exclusively at the mouths of suspected spawning streams,only subadults and juveniles were captured at mainstem sites and sloughs not affected by the tributaries.Although recapture data on longnose suckers was limited,the findings generally agree with other studies of Alaskan longnose sucker populations in alaska.The juveniles apparently drift out of the tributaries,rear in the mainstem,and then return as adults to the tributaries to spawn.The adults often remain in the vicinity of the tributary mouth for much of the summer (Morrow,1980). Large concentrations of juvenile fish were observed in the mainstem sloughs. Both round and humpback whitefi sh were captured duri ng the fall at or near the mouths of tributary streams.No information on their summer range in the proposed impoundment area has been collected.Juvenile whitefish have been observed at the mouths of tributary streams and in mainstem sloughs. Arctic grayling were captured in the mainstem Susitna only near the mouths of tributary streams.These fish were generally subadults which were not large enough to defend a territory in the stream itself. DRAFT FIVE/4.0 4.3 Lake Habitat and Fisheries Investigations Thirty one lentic habitats (lakes or small ponds)have been identified within the boundaries of the proposed Devil Canyon and Watana impound- ments (Acres,1982).Twenty seven of these habitats are less than five acres in size.Due to the small size and shallow depths of the majority of these habitats it is assumed that most are not capable of supporting fish populations.Preliminary aerial surveys of many of these habitats support this assumption.Due to limited time and personnel,lake sampling efforts during 1982 were l"imited to Sally Lake,the largest lake within the proposed impoundment boundaries.More effort should be directed toward other lentic habitats in 1983 to verify the presence or absence of fish in these areas. 4.3.1 Resident Fish Species In 1982,an attempt was made to estimate the fish population of Sally Lake.The original study plan was to utilize large hoop nets and hook and line sampling to capture fish.Gill nets were excluded as a 67% mortality rate was encountered during 1981 gill net sampling. The hoop nets were not as effective as had been anti ci pated with an average catch rate of only 0.68 lake trout per day.The trap itself was found to be 1a rge enough but the 25 foot 1eads (wings)were much too short.Traps with 100 foot leads may have been more effective.In addition,the mesh size used in the trap was too large to effectively capture Arctic grayling;individuals were occasionally gilled. ----------_.._-_.... DRAFT FIVEj4.0 Hook and line sampling was the most effective method with a catch rate of 0.76 lake trout per hour.The use of this method allows the entire lake to be sampled,as opposed to the stationary hoop nets.The major drawback of hook and line sampling is the time involved;hoop nets can be set and then checked daily whereas hook and line sampling requires the actual presence of biologists for extended lengths of time. Experimental use of a wide angle sonar vertical proved that fish could be distinguished and counted,but because of the shallow depth,the area of the lake which could be sampled by a transect is extremely small, necessitating a large number of transects to be made.Also,a large portion of the bottom of Sally Lake is covered with large aquatic plants extending,in some cases,all the way to the surface.These plants effectively mask any recording of fish present.Therefore,in 1982,a study program util izing more hoop nets with longer 1eads and more sampling time should result in a large enough sample size to generate a population estimate.In addition,the use of side scan sonar as an alternative method will be tested. The recapture of 2 of 35 tagged lake trout provides an idea of the order of magnitude of the population.It is generally believed that the population of lake trout is below 1,000 fish.The Arctic grayling population is believed to be somewhat larger,possibly in the vicinity of 5,000 fish.These estimates are based on observations of large schools and the small size of the fish. ISO 1it cited/rapup LITERATURE CITED Acres American,Inc.(Acres).1982.Susitna hydroelectric project draft FERC license application,exhibit E.Anchorage,Alaska. Alaska Department of Fish and Game (ADF&G)1978.Preliminary environmental assessment of hydroelectric development of the Susitna River. Anchorage,Alaska. 1981a.Aquatic habitat and instream flow,phase 1 final draft subject report.ADF&G Su Hydro Aquatic Studies Program. Anchorage,Alaska. 1981b.Adult anadromous phase 1 final species/subject report. ADF&G Su Hydro Aquatic Studies Program.Anchorage,Alaska 1982a.Procedures manual.ADF&G Su Hydro Aquatic Studies Program.Anchorage,Alaska. 1982b.Aquatic studies program phase 1 final draft report.ADF&G Su Hydro Aquatic Studies.Anchorage,Alaska 1983a.Su Hydro draft basic data report,volume 4,part 1. ADF&G Su Hydro Aquatic Studies Program.Anchorage,Alaska. 1983b.Su Hydro draft basic data report,volume 2.ADF&G Su Hydro Aquatic Studies Program.Anchorage,Alaska. A1t,K.1976.Inventory and cataloging of North Slope waters.Alaska Dept.of Fish and Game.Federal Aid in Fish Restoration,Annual Report of Progress,1975-1976,Project F-9-8,17(G-1-0):129-150. Armstrong,R.H.1982.Arctic grayling studies in Alaska,draft. Alaska Cooperative Fishery Research Unit.University of Alaska, Fairbanks,Alaska USA.(unpublished) Lind,a.T.1974.Handbook of common methods in limnology. The C.V.Mosby Co.,Saint Louis,Mo. Morrow,J.E.1980.The freshwater fishes of Alaska.Alaska Northwest Publishing co.Anchorage,Alaska. Nelson,P.H.1954.Life history and management of the American grayling (Thymallus signifer tricolor)in Montana.J.Wild.r~anage. 18:324-342. R&M Consultants,Inc.1982.Provisional metero10qica1 data for the Susitna River Hydroelectric proposed impoundment -area to be published in:Field data collecting and processing.R&M Consultants, December 1982. Tack,S.L.1973.Distribution,abundance,and natural history of the Arctic grayling in the Tanana River drainage.Alaska Dept.of Fish and Game, Federal Aid in Fish Restoration,Annual Report of progress,1972-1973, Project F-9-5,14(R-I). lit cited/rapup lITERATURE CITED (Continued) U.S.Fish and Wildlife Service.1952.A preliminary statement of fish and wildlife resources of the Susitna Basin in relation to water development projects. 1954.A progress report on the fishery resources of the Susitna River Basin.Juneau,Alaska. 1957.Progress report,1956 field investigations Devil Canyon Damsite,Susitna River Basin.Juneau,Alaska.- 1959a.Progress report,1957 field investigations Devil Canyon Damsite and reservoir area,Susitna River Basin.Juneau,Alaska. 1959b.1958 field investigations Denali and Vee Canyon Damsites and reservoirs areas,Susitna River Basin.Juneau,Alaska. 1960.A detailed report on fish and wildlife resources affected by the Devil Canyon Project.Bureau of Commercial Fisheries.Juneau, Alaska. 1965.A detailed report on fish and wildlife resources affected by the Vee Project.Juneau,Alaska. U.S.Geological Survey (USGS).1978.Surface water records of Cook Inlet Basin.Alaska,through September,1975.Open file report.Number 78-498.Anchorage,Alaska. 1981.Provisional discharge and water quality data to be published in:Water Resources Data for Alaska,water year 1981. Anchorage,Alaska. 1982.Provisional discharge and water quality data to be published in:Water Resources Data for Alaska,water year 1982. Anchorage,Alaska. Vascotto,G.l.and J.E.Morrow.1973.Behavior of the Arctic grayling, Thymallus arcticus,in McManus Creek,Alaska.Biological Papers University of Alaska.No.13.p 29-38. Wetzel,R.G.1975.limnology.W.B.Sanders Company.Philadelphia, london and Toronto. APPENDIX SA Statistical Analysis VOLV/TABLES/PAGEI 830209/Stratton TABLS/Statistical Analysis VOLVjTABLESjPAGE2 830209jStratton TABL5jStatistical Analysis POPULATION ESTIMATES Adjusted Petersen Single Census Method (Ricker,1975 pg.78) N = (M+1)(C+1) R+l where: N size of population at time of marking M number of fish marked C catch or sample taken for census R number of recaptured marks in the sample ~;J-/ VOLV/TABLES/PAGE3 830209/Stratton TABL5/Statistical Analysis CONFIDENCE LIMITS Confidence Limits For Variables (x)Distributed In a Poisson Frequency Distribution,For Confidence Coefficients (=l-P)of 0.95. (Ricker,1975 pp.78,343) For 1-P =0.95 x+1.92±1.960 /x+1.0 MORTALITY AND SURVIVAL MORTALITY (EVERHART ET AL.1976,pp.104-109) and Z =-lnS or alternatively S =l/eZ where: Nt is number of fish at time t VOLV/TABLES/PAGE4 830209/Stratton TABL5/Statistical Analysis No is number of fish at time equal 0 Z is the force of total mortality and Sis surv i val APPENDIX 58 Maps of the proposed impoundment area of selected tributaries and the adjacent Susitna River within the impoundment study area. EXISTING LAKES o I PROPOSED "';-IMPOUNDMENT AREA TRM _TRIBUTARY RIVER MILE .- .~ .'--TRM I.7 o EVIL CANYON DAM SITE .- Fi qure 5-11-1 Proposed Devil Canyon impoundment area of Cheeckako Creek,RM 152.4,and adjacent Susitna River. ~ (,) ..-r () () ",""-.c:.... <: ~ mile o I TRM - EXISTING ,LAKES PROPOSED IMPOUNDMENT AREA TRIBUTARY RIV ER MILE Fi oure 5-8-2.,Proposed Devil Canyon impoundment area of Chi nook Creek,RM 157.0,and adjacent Susitna River. :)-R -1. mile III -EXI STING LAKES PROPOSED IMPOUNDMENT AREA TRM _TRIBUTARY RIVER MILE o I Figure 5-B-3 Proposed Devil Canyon impoundment area of Devil Creek,RM 161.4,and adjacent Susitna River. oIIImileEXISTINGLAKESPROPOSEDIMPOUNDMENTAREATRIBUTARYRIVERMILE~~,-.1~~ty­.(,e;',,0IIIIIITRM-~0:sr'*Figure5-B-4ProposedDevilCanyonimpoundmentareaofFogCreek,RM176.7,andadjacentSusitnaRiver. TRM a I mile 111 _EXISTING LAKES PROPOSED -IMPOUNDMENT AREA TRIBUTARY -RIVER MILE Figure 5-B-5 Proposed Devi 1 Canyon impoundment area of Tsusena Creek,RM 181.3,and adjacent Susitna River. -----,------_._--_._---_.'-,.._-_.',,," o I mile PROPOSED -IMPOUNDMENT AREA TRM _TRIBUTARY RIVER MILE Figure 5-B-6 ----------------.. Proposed Watana impoundment area of Deadman Creek,RM 186.7,and adjacent Susitna River. Figure 5-B-7 o I mile !.··ilil~h%~~~~~ENT TRM -TRI BUTARY RIVER MILE HABITAT --EVALUATION SECTIONS Proposed Watana impoundment area of Watana Creek,RM 194.1,and adjacent Susitna River. )-/3-7 Figure 5-B-8 4.5 o I mile ~_EXISTING ~LAKES ti!fl-~:;;~~:~~ENT _POOLS (POOL C A- N WAS ELIM INAT ED) TRM -TRI BUTARY RIVER MILE Proposed Watana impoundment area of Kosina Creek,RM 206.8 and adjacent Susitna River. o I mile __EXISTING LAKES I;~~\,~;\;i'-~~~3~~~EN T TRM -TRIBUTARY RIVER MILE , Fiqure 5-8-9 Proposed Watana impoundment area of Jay Creek.RM 298.5.and adjacent Susitna River. ,~--B-9 o I mile 111 -EXISTI NG LAKES PROPOSEDt~\t;f;l!I~t-~M~OAU NDMEN T TRIBUTARY TRM -RIVER MILE Fiaure 5-8-10 Proposed Watana impoundment area of Goose Creek,RM 231.3,and adjacent Susitna River. ~B-/{-}:~-"~ Figure 2.2 o I mile _-EXISTING LAKES PROPOSED~,t;;G;~[,,;;;i-~~~~UNDMENT A-G·POOLS TRM-TRIBUTARY RIVER tit ILE Proposed Watana impoundment area of the Oshetna River,RM 233.4,and adjacent Susitna River. ~/)J-// APPENDIX 5C Selected water quality data for habitat evaluation sites within the impoundment study area. VYTABLES/PAGE1830209/JOETABL5/SelectedWaterQualityTable5-C-1.SelectedtributarywaterqualitydatacollectedimmediatelyabovethemouthofCheechakoCreek,RM152.4,GCS32N01E33CCB,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)P.!!(umho/cm)AirWater(NTU)82080615259.8947.030----11.6820808155510.4987.223----10.8820811143011.11007.02217.09.4<,1~'"--Dataavailable'"I....---Table5-C-2.SelectedtributarywaterqualitydatacollectedimmediatelyabovethemouthofDevilCreek,RM161.4,GCS32N02E34AAC,1982.DODO(mg/l)(%sat)Temp.-°CTurbidityAirWater(NTU)Date820822Time093011.297pH7.3Spec.Condo(umho/cm)579.67.4--Dataunavaila~le VC)TABLES/PAGE2830i09/JOETABL5/SelectedWaterQualityTable5-C-3.SelectedtributarywaterqualitydatacollectedimmediatleyabovethemouthofFoqCreek,RM176.7,GCS31N04E16DBB,1982.DODOSpec.CondoTemp.-°CTurbidityDate.Time(mg/l)(%sat)pH(umho/cm)AirWater(NTU)820505153013.2977.4--4.71.1820516134513.5977.53711.00.44820528163011.8937.1636.03.53820621113011.6946.95010.84.52\)'f820718113011.51007.26514.87.5.c18208151300------- ---9915.89.4<1\820912115512.41087.5838.13.6<I("-,,--Dataunavailable...Q...~\Table5-C-4.SelectedtributarywaterqualitydatacollectedimmediatleyabovethemouthofTsusenaCreek,RM181.3,GCS32N04E36ADB,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)820505150014.01047.3---4.71.4820515170513.81007.41217.80.35820528142012.2946.9967.02.6<1820619114011.4957.03318.25.32820718143011.61037.25715.87.9<1820728160011.31057.261----9.98208161210----------9715.87.9<1820912141511.6987.48710.25.9<1--Dataunavailable VC)TABLES/PAGE3830l09/JOETABL5/SelectedWaterQualityTable5-C-5.SelectedtributarywaterqualitydatacollectedimmediatleyabovethemouthofDeadmanCreek,RM186.7,GCS32N05E26CDB,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!:!(umho/cm)AirWater(NTU)820505143014.21047.3--4.80.8820516124513.81007.461----0.57820528133012.7947.0535.80.92820619131011.2957.02817.86.17820718101011.11037.55910.69.618208161645----------7516.813.9<1U'\_820911122511.71007.1669.16.6<1\(.:J--Dataunavailable\,~--\jTable5-C-6.SelectedtributarywaterqualitydatacollectedonemileabovethePIEonDeadmanCreek,TRM3.7,GCS32N05E13BBB,1982.DODO(mg/l)(%sat)Temp.-°CTurbidityAirWater(NTU)Date820720Time091010.3104£!:!6.8Spec.Condo(umho/cm)5619.411.9<1 VC)TABLES/PAGE483lU09/lJOETABL5/SelectedWaterQualityTable5-C-7.SelectedtributarywaterqualitydatacollectedimmediatleyabovethemouthofWatanaCreek,RM194.1,GCS32N06E25CCA,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)820505142014.11027.5---4.80.1820517120013.11007.4828.01.917820525213010.1776.71014.72.28205261620·11.3937.110411.54.9258206201800l1.7997.06312.85.7882062318309.9977.410821.811.97".:'\82062418009.6997.411424.112.7820628091510.4947.410318.28.5820718170010.81027.6151----9.820f~820726095012.11057.212213.87.08820729120011.01007.616315.09.1',·t820811070012.51057.31698.06.2"820812080012.81047.51914.84.0<1820813074011.9997.51956.45.4820814070011.01007.6194----8.3820815073012.21057.62009.67.08208160720----------2067.06.0820817082010.4907.41849.06.8820818070011.91007.31866.85.9820819061512.51047.41881.65.1820820073012.01017.51917.66.0820821073011.5997.41918.46.5820822065011.7987.51982.85.4820823073010.1907.520211.48.0820824074011.3997.5206----7.1--Dataunavailable Table5-C-7.Continued.VO~ABLES/PAGE5830,09/,lOETABL5/SelectedWaterQualityDODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!i.(umho/cm)AirWater(NTU)820825070011.0977.22118.47.7820826073011.4997.42127.16.6820909064511.8987.11646.45.1\'}'>1820910073011.9977.21724.84.7820911073013.21027.21763.63.1I820912073013.21047.21831.83.0(~820913080012.51007.31694.83.9\"-l\820914073012.11007.01186.44.7~)\820915074511.8987.21049.65.0820916080011.4957.31055.8 5.3820917073012.41007.21243.24.09820918074512.71007.11343.03.6820919074510.4857.21477.14.68209200745-------7.31474.23.8--Dataunavailable <..1rI(~If\"'-VO~ABLES/PAGE6830t09/JOETABL5/SelectedWaterQualityTable5-C-8.SelectedtributarywaterqualitydatacollectedwithinthetwomilestudysectionofWatanaCreek,TRM5.0,GCS32N07E17BAD,1982.DODOSper:oCondoTemp.-°cTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)82062616009.9957.49626.010.9820729130011.41057.214214.59.0820825124011.11027.6184----8.5--DataunavailableTable5-C-9.SelectedtributarywaterqualitydatacollectedintheEastForkWatanaCreek,TRM9.2,GCS33N07E34CCA,1982.DODO(mg/l)(%sat)Date820825Time120010.798pH7.6Spec.Condo(umho/cm)80Temp.-°cTurbidityAirWater(NTU)8.1--DataunavafTa6le VC)TABLES/PAGE7830t09/IJOETABL5/SelectedWaterQualityTable5-C-10.SelectedtributarywaterqualitydatacollectedintheWestForkWatanaCreektTRM9.6tGCS33N07E34CCAt1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)820825123511.21027.7193----8.2--Dataunavailable,\J"tt.\(Table5-C-11.Selectedtributarywaterqualitydatacollectedimmediatelyabovethemouthof(.....,KosinaCreektRM206.8tGCS31N08E15BABt1982.\'-'i"'-"-J.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)pH(umho/cm)AirWater(NTU)820504163014.11087.2--4.71.8820504180014.11077.1------1.5820505113014.11047.6--4.30.8820505]23013.51007.5------1.1820505163013.81047.6------1.4820505193014.01047.5--0.41.0820513120013.4977.4892.80.6820515120012.6947.3797.81.52820516120013.2987.568----1.2820526140011.8916.84312.02.32820623120010.1937.33721.09.0382062710309.9947.13920.110.0820726120511.01067.36817.811.2<1820812113011.01007.37013.28.4<1820914133511.91047.26211.86.8. 1--Dataunavailable VOltABLES/PAGE8830~09/JOETABL5/SelectedWaterQualityTable5-C-12.SelectedtributarywaterqualitydatacollectedonemileabovethePIEonKosinaCreek,TRM5.5,GCS30N08E04CBD,1982.DODO(mg/l)(%sat)Temp.-°CTurbidityAirWater(NTU)~)\l'\(\......Date820724Time094511.0106pH7.2Spec.Condo(umho/cm)6115.810.12\"-X!Table5-C-13.Selectedtributa~ywaterqualitydatacollectedimmediatelyabovethemouthofJayCreek,RM208.5,GCS31N08E13BCC,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)820505131513.91007.8---4.80.3820516110013.4987.67710.00.614820529100012.0947.16010.02.93782062416009.9988.110327.212.119820726112511.71058.015819.28.12820812120011.3997.717814.46.9<1820915151010.7977.912015.88.23--Dataunavailable lTable5-C-14.v'YTABLES/PAGE983u209/lJOETABL5/SelectedWaterQualitySelectedtributarywaterqualitydatacollectedimmediatelyabovethemouthofGooseCreektRM231.3,GCS30N11E32DBC,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)E!!(umho/cm)AirWater(NTU)820505134513.31007.4--4.90.5820514080013.81007.1472.50.21820618143011.2976.83411.06.12820621163010.01047.36517.014.0<182062712009.6967.24822.312.0\.A.82072815009.71037.377----14.8II82081816459.71007.46917.213.0<1820910142511.2987.26810.66.6<1C'\I--Dataunavailable~~Table5-C-15.SelectedtributarywaterqualitydatacollectedonemileabovethePIEonGooseCreek,TRM2.2,GCS29N11E07CCA,1982.DODO(mg/l)(%sat)Temp.-°CTurbidityAirWater(NTU)Date820621Time185010.2107E!!7.2Spec.Condo(umho/cm)5915.4 13.2<1 JV()TABLES/PAGElO83lJt09/JOETABL5/SelectedWaterQualityTable5-C-16.SelectedtributarywaterqualitydatacollectedimmediatelyabovethemouthoftheOshetnaRiver,RM233.4,GCS30N11E34CCD,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)~(umho/cm)AirWater(NTU)820505140014.31057.7---4.90.1820527140011.4927.25610.83.45820627113510.2947.35019.68.74282071916509.61017.59923.014.46820728144010.21067.5115----13.9820820180510.41067.811419.212.828209091540.11.0987.4128.10.27.1<1\)',\\--Dataunavailable(~I""'.,\","-.JTable5-C-17.SelectedtributarywaterqualitydatacollectedonemileabovethePIEontheOshetnaRiver,TRM3.2,GCS29N11E16ACC,1982.DODO(mg/l)(%sat)Temp.-°CTurbidityAirWater(NTU)Date820719Time17009.9105pH7.6Spec.Condo(umho/cm)9824.814.52 \).'11('\-...JI"-..~...........V()TABLES/PAGEll83uZ09/JOETABL5/SelectedWaterQualityTable5-C-18.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandFogCreek,RM176.7,GCS31N04E16DBB,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)820621113510.7937.08410.87.366820718114010.6947.29214.68.63682081513159.0837.211015.89.785820912115011.0917.41288.15.724Table5-C-19.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandTsusenaCreek,RM181.3,GCS32N04E36ADB,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)£!!(umho/cm)AirWater(NTU)820619120010.2937.27318.88.838820718144010.3997.512216.611.01408208161200----------11915.810.3150820912141011.71007.512710.26.225--Dataunavailable VC)rABLES/PAGE12830~09/JOETABL5/SelectedWaterQualityTable5-C-20.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandDeadmanCreek,RM186.7,GCS32N05E26CDB,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)Eli(umho/cm)Air~Jater(NTU)820619131510.2937.38017.88.738820718100010.7988.113610.69.01358208161650---------11616.810.8140820911122011.5977.41369.15.833~--DataunavailableI',\......I"3<.:......Table5-C-21.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandWatanaCreek,RM194.1,GCS32N06E25CCA,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)Eli(umho/cm)AirWater(NTU)820623100010.3987.29217.010.648820726101011.51056.811716.09.0150820812103010.8997.513812.49.1100820915164510.7967.612813.08.2100 ~}l\(~:""(jjvctrABLES/PAGE13830209/JOETABL5/SelectedWaterQualityTable5-C-22.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandKosinaCreek,RM206.8,GCS31N08E15BAB,1982.DODOSpec.CondoTemp.-DCTurbidityDateTime(mg/l)(%sat)pH(umho/cm)AirWater(NTU)82062711009.5957.410821.013.0130820726105511.01027.311617.69.4130820812113010.0987.213313.29.580820914133011.3977.313411.86.328Table5-C-23.SelectedwaterqualitydatacollectedinLowerJayCreekSlough,RM208.1,GCS31N08EIIDCD,1982.DODO(mg/l)(%sat)Date820814Time11306.470pH7.3Spec.Condo(umho/cm)358Temp.-DCTurbidityAirWater(NTU)16.5--Dataunavailable \·-,tIr-...,"'"."l::I.II!VCJTABLES/PAGE1483lJL09/aOETABL5/SelectedWaterQualityTable5-C-24.SelectedwaterqualitydatacollectedinUpperJayCreekSlough,RM208.7,GCS31N08E13BCD,1982.DODOSpec.CondoTemp.-°cTurbidityf1ateTime(mg/l)(%sat)£!i(umho/cm)AirWater(NTU)82052914304.8596.845210.66.6182062416206.3657.039827.213.682072611108.7776.747319.27.5782081211458.3726.839614.06.6482091514559.9917.140115.88.73--DataunavailableTable5-C-25.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandUpperJayCreekSlough,RM208.7,GCS31N08E13BCD,1982.DODOSpec.CondoTemp.-°cTurbidityDateTime(mg/l)(%sat)pH(umho/cm)AirWater(NTU)820529151510.8917.08910.25.34282062416159.6997.59627.213.946820726112011.01017.711519.39.0130820812114511.5987.013914.09.4140820915145010.7967.712415.08.098 VChABLES/PAGEI5830t09/,JOETABL5/SelectedWaterQualityTable5-C-?6.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandGooseCreek,RM231.3,GCS30NIIE32DBC,1982.DODOSpec.CondoTemp.-°cTurbidityDateTime(mg/l)(%sat).P.!!(umho/cm)AirWater(NTU)820514093013.5987.3102.50.114820514120013.0947.2833.50.266820618144010.6957.09511.07.13382063012459.5947.49322.011.4820721164010.41057.511617.012.4125A820728150010.51027.7124----11.2\~820818165010.3956.611317.28.7110I820910144011.4997.213810.66.032r~(--Dataunavailable~\/'\Table5-C-27.SelectedmainstemwaterqualitydatacollectedimmediatelyabovetheconfluenceoftheSusitnaRiverandtheOshetnaRiver,RM233.4,GCS30NIIE34CCD,1982.DODOSpec.CondoTemp.-°cTurbidityDateTime(mg/l)(%sat).P.!!(umho/cm)AirWater(NTU)820527140511.1937.15911.04.73682062711309.5997.612219.613.4140820719J.645,10.21047.5128.23.012.6140820728144510.51037.7125----11.6820820181010.41007.712219.210.5110820909155011.1966.714410.26.343--nataunavailable VO.ABLES/PAGEI6830Z09/JOETABL5/SelectedWaterQualityTable5-C-28.SelectedwaterqualitydatacollectedinSallyLake,GCS32N07E29,1982.DODOSpec.CondoTemp.-°CTurbidityDateTime(mg/l)(%sat)pH(umho/cm)AirWater(NTU)82062315008.0907.3111----16.982072912408.1897.512215.216.082081916007.5827.511418.815.782082213308.0917.711320.617.482090817107.6757.01139.811.3i'"1--DataunavaTTa6le.\(~-.\I~ APPENDIX 50 Planimetric maps of selected Susitna River habitat evaluation sites within the impoundment study area. ~:.:•..:.."'....::.:::.;.~. Silt Sand Gravel Rubble Cobble IIUtl' River Mile (RM) Eddy Study Area Boundary Mixing Zone Small Tributary Boulder Figure 5-0-1 ~True North Planimetric map symbol legend for selected mainstem Susitna River habitat evaluation sites,Proposed Impoundment Areas,1982. III((r\':J\Z,I,-".!(IcobblearubbleTr...900'\;.~._.SUSlrNANIVERSub.trateUnknownTn..Tre..''-'',,-..:---;-_.;.o2~OIIFEETFigure5-0-2MainstemSusitnaRiverhabitatevaluationsiteNo.1,RM189.0,GCS32N06E31ABC. JMainstemSusitnaRiverhabitatevaluationsiteNo.2,RM191.5,GCS32N06E28CAC.Ef)191.5R/V E RSubstrateUnknownSUS/TNATrees750'TreesFigure5-D-3o250IIFEET~~\W ~.~\~•l_--------)AREAill194.0-<_SUS/TNAR/VERTr...300'Sub.frateUnknowno250IIFEETFigure5-0-4~~ainstemSusitnaRiverhabitatevaluationsiteatWatanaCreek,RM194.1,GCS32N06E25CCA. ~•••I/.11t2250'Tr...~~:~:{;";':'"i';"'.~I":~~;:::~'",.~~.":-lpn._.,..,~..,STUDY~-• _ •...JAREA""h_~PgrOVll/rubbl.Jf~'~Tr•••1\RiVERrN'"US'U~~~O~~S\(o,es~~'/grov.i/rubbl.~tll1ff{lJ?Tr..,o!SOOIIFEET~tJii.A\Figure5-D-5MainstemSusitnaRiverhabitatevaluationsiteNo.3,RM197.8,GCS32N07E33DBC. '--~ItyIG"-SubstrateUnknownTreeso250IIFEET201.0EB~sus/rNARIV£R---TreesFigure5-0-6MainstemSusitnaRiverhabitatevaluationsiteNo.4,RM201.2,GCS31N07E12BCB. Tr•••Tr•••E9201.2250'STUDYAREA\_-r-SubstrateUnknown---sus/rNAR/VER--__Q)\.~\\:JI"'JII-Tr••so250IIFEETFigure5-D-7MainstemSusitnaRiverhabitatevaluationsiteNo.3A,RM201.6,GCS31N07E12BDB. uot::Ji~)EB208.0800'Tr..'AREAsus/rNA'~Tn..RIVERFigure5-0-8Sub.trateUnknowno2!iO,IFEETt1ainstemSusitnaRiverhabitatevaluationsiteNo.5,RM208.1,GCS31N08EllOCO.