HomeMy WebLinkAboutLower sustina river water surface profiles and discharge rating curves 1983... :;4>"" 1 I . 1 . ,~~ 1 . .,. I l ' ' ... ~ ' SUSITNA HYDROELECTRIC PROJECT I LOWbR SUSITNA RIVER I -WATER SURFACE PROFILES AND DISCHARGE RATING CURVES ·t I I I I 'I I Prepared by Harza-Ebasco Joint Venture I For Alaska Power Authority October 1983 I HARZA·EBASCO Susitna Joint Ventur& t Document Number I •• JC8 ~------~--~~--~~ Please Return To DOCUMENT CONTROL ·~ " ~· . ~ ' U I • 1 1 11>' 1· -~ -~I '~! ,, ( J., l:t. '". ''./ ' -~ 1 '!II : L! )qt L )• ~~ ~ '-~: l I --~ -,, -~ ,ll ''~ ''"' ~~ ' ) i I J I ' I i ' • 1- I I I I • • I I Table of Contents Introduction Background Scope of Present Study Review of Previous Study Present Study Study Reach River Cross-sections Initial "n" Values Control Points HEC-2 Model Set-up Refinement of HEC-2 Model Calibration Stage-Discharge Rating Curves Mainstream River Velocity Discussion Recommendations References Tables Figures Appendices . -1- Page 1 1 2 3 6 6 7 7 7 9 9 13 13 14 15 18 I ' 11 I -~: I I ' ' . I I I Table 1 2 3 4 5 6 Exhibit 1 2 3 4 5-78 List of Tables Title Manning's Roughness Coefficient ('n' values) comparison of Observed and Computed Water Surface Elevations variation in Water Surface Elevation Between Channels at a Cross Section River Reaches and Corresponding Discharges Water Surface Elevations Mean Velocities List of Exhibits Titlo Locations of River Cross Sections Locations of River Cross Sections, Staff Gages and Sloughs Susitna River Bed Profile and Water Surface Profiles for 9,700 cfs Water Surface Profiles Stage-Discharge Rating Curves -ii- rl: ! ~. • • - I -' . • I • ~ I •• • • ~ 1~. ,.. c, ........ Introduction This report presents the results of a study on water sur- face profiles of the susitna River between Sunshine and the downstream end of Devil Canyon under open water conditions for a selected range of discharges (see Exhibit 1). The u.s. Geologi- cal survey (USGS) is maintaining a stream gaging station at sunshine, downstream end of the study reach. The station is located abcut 84 miles from the mouth of the Susitna River at Cook Inlet (the mouth). The upper end of the studv reach near the mouth of Devil Canyon is about 150 miles from the mouth. The discharge rating curves ba~ed on the computed water surface profiles are presented for s~lected locations, especial- ly at immediate upstream and downstream of important sloughs • Mean river velocities also are provided at surveyed cross sections for a range of discharge values5 Background The water surface profiles for the Susitna River between the downstream end of Devil Canyon and the confluence of the Susitna and Chulitna rivers were developed previously by R&M Consultant Incorporated, Anchorage, Alaska (R&M) for the dis- charges of 9,700, 13,400, 17,000, 23,400, 34,500 and 52,000 cubic feet per second (cfs). All discharges were referenced to the gaging station at Gold Creek (the Gold Creek gage). The results of R&M studies including field surveys are presented in -1- • • I t .. I I • ' • ., It I IJ IJ various reports (1, 2, 3,)~/. These reports were prepared by R&M for Acres American Incorporated (ACRES) for submission to Alaska Power Authority (APA). since the R&M study of March 1982 (2), 32 additional . r1ver cross sections have been surveyed (3) in the study reach. Five old cross sections were al3o resurveyed. The 0ld and new cross- sections are identified on Exhibit 1. Alaska Department of Fish and Games {ADF&G) has established a number of staff gages in the study reach. The water levels at these gages were observed periodically during July through October, 1982 and were referenced to the flow at the Gold Creek gage (4). The water levels data also are available for 1983. Scope of Present Study The availability of additional surveyed river cross sections and river stage data permits the refinement of water surface computations made by R&M. The major works involved in the present study include: 1. a review of basic data, study approach and assumptions used by R&M in the computations of water surface profiles; 2. a refinement of previous calibration by R&M of the HEC-2 Computer model developed by the U.S. Army Corps ll Refers to reference at the end of text. -2- ~! ·~! .= ·.~ ,~f! .~· .... l i:~ l L· -~1 t~ 3: ·, ~tt .• ~ : r . ~ 1 ·'* ·.t'·f '··· ~ :r : ' ! " ' • ' ( l I ; l I I I 1 j !1 ~j j .. l 'If I t-)·., { :; .. ~ J J (..'i 1 :.i il ~ ' 1l l I I ~I ' I • • I .. ;;; - •• I • ~ - I li Jt ~ . ' ' Jfl ·;. ' . .(1 . "" of Engineers (5) based on additional cross sections and river stage data; and 3. a recomputation of water surface profiles for 9 different discharges at appropriate intervals to define stage-discharge rating curves at selected locations. Revi~~ of Previous Study The HEC-2 model uses standard step method (6) to compute water surface profiles based on the Bernoulli theorem and the Manning's equation between river cross sections. This model was used by R&M to compute water surface profile by using a total of 66 river cross sections (No. 3 to No. 68) ~s identified on E:xhibi t 1 • An extensive analysis was made by R&M to estimate the val- ues of Manning's roughness coefficients (the 'n' values). Ini- tially, these values were estimated at eight staff gages (see Table 2) using observed water surface elevations and correspond- ing discharges with the assumption that the friction slope at each cross section is approximately equal to the average bed slope over the reach from the next-upstream cross section to the next dowstream cross sect:~n. The 'n' values were computed fer discharges ranging between 3,000 to 50,000 cfs, and an average ~elationship between the 'n' values and the discharges was developed (Figure 4.4, reference 2). Ths vn' val•1es were also estimated using bed material size distribution {7) determined by the "Grid-by-Number method (B)i -3- I I I 11 1 I i I ,, • ·.I '.; '' i ' i 'I ·1 • I ' ,) I • ' • I I II It • It . J; _,,.J However, the 'n' values derived by the two methods were used only as a reference in selecting an initial values for each cross sections at a discharge of 9,700 cfs at Gold Creek. No horizontal or vertical variation of 'n' value was considered except at cross section No. 25 where the 'n' values were adjusted horizontally. Multi-channels exist at this cross sec- tion and the velocities in each channel are significantly dif- ferent. Therefore, the 'n' values were increased in some chan- nels to decrease the conveyance • The HEC-2 model was first calibrated for the discharge of 9,700 cfs at the Gold Creek gage. For the computations of water surface profile, this flow was decreased for the river reach upstream from the Gold Creek gage and increased for the down- stream reach baseo on the intervening drainage areas. The adjustment factors used for different sub-reaches are (see Exhibit 1 for locations) shown in the following table: ADJUSTMENT FACTORS BASED ON DRAINAGE AREAS Cross Sections From To 3 24 51 62 23 50 61 68 Factor to adjust Gold Creek Flow 1.030 1.000 0.983 0.942 The refinement of the initial 'n' values during the clibra- tion took into consideration several criteria including bed material size, river sinuosity, presence of and type of vegeta- -4- I I I -;· • I I~ -. I I I I ' I ·.; I 1 : j :; ; I ,; I j I ~ I ~ ·l·; ! I d~ '! " 1 I- I • • I • J I'· I ' . .J tion, existence of multiple channels, etc. The final 'n' :ralues are given Table 1. The •n• values derived for 9,700 cfs were adjusted by the following factors to estimate those for other calibration dis- charges of 17,000, 34,500 and 52,000 cfs. These factors were probably derived through a trtal-and-error procedure although it is not mentioned in the reports {2)~ ADJUSTMENT FACTORS FOR 'n' VALUES Discharge 17,000 34,500 52,000 Adjustment F'actor 0.90 0.81 0.81 A comparison of observed and computed stages at eight staff gage locations (used as control points) given in R&M's March 1982 report (2, Table e.l5) is shown in Table 2. Based on their field experience, aerial photos, and sur- veyed river cross sections, R&M classifed flows in the Susitna River into two flow regime; a low flow regime and a high flow regime. A numher of side channels and sloughs which receive water during the high flow regime of over 20,000 cfs at Gold Creek are practically dry during the low flow regime of below 20,000 cfs. Therefore, two versions of HEC-2 model were set up • For discharges up to 20,000 cfs, the assumption was made that there are no flows in some selected side channel and sloughs. In the second version, flow was assumed to exist in all channels for discharges higher than 20,000 cfs. -5- -.-·-,..~-.. ~· . ~ '•. ; ... . . r-" ~" It ,. •• "'-.. ~:r~~ •~.ot.Li·~'·':·• •:'~,.;:~ •:• ~,~:..,~._• •• • • : • ; • -~ ~l~~ • t ' : '-'• ~ • ~· >: ~ ~~ n . ; . . -. -. ~ ,. ~ ..... t. • ., ."W< '-• -~ ' •• I I 'I I I I I I I· I I I I I '">' ~ 1\ . .r: If, \ ::.. A review of Table 2, indicates that the differences between observed and computed stages at the eight control points used by R&M are within + 0.5 ft except at a few coss sections for a few discharges. The hi§her differences at these cross sections (especially for lower flow ranges) are mostly due to multi-chan- nel situation with the staff gages being located in the side channels where the mainstem water level is not accurately repre- sented. Water surface elevation across a multi-channel cross section is not uniform as assumed in the computations of water surface profiles by the HEC-2 model. R&M collected data on differences in elevations across multiple-channel cross sections (2, Tables 4.5 and 4.6). These data are shown in Table 3 which provides an indication of possible deviation between observed and computed water surface elevationso Present Study The HEC~2 computer mode~ used by R&M was used to compute water surface profiles for this study. The model calibration was refined using additional cross-sections and river stage data. The basic data and assumptions used and the results obtained are discussed below. Study Reach The length of the study reach is about 66 miles between cross sections Nos. 68 and 001 (Exhibit 1} in comparison to the reach between cross sections Nos. 68 and 3 used by R&M. The study reach was extended to the sunshine gaging station (cross section Number OOl)to provide approximate estimation of water -6- I I I I I I I I I 'I I I • I ~~ .l surface elevations for varius discharges near the confluence of the sustina, Talkeetna and Chulitna rivers. River Cross Sections A total of 107 cross sections were used for the computa- tions. This included 68 cross sections surveyed in 1981, 33 cross sections surveyed in 1982, five cross sections estimted from USGS topographic maps of 1:63360 scale and one cross sec- tion taken from field notes of a discharge measurement by USGS at Sunshine Station. All of these cross sections are identified on Exhibit 1. During the 1982 survey, the cross sections were surveyed in the river channels only and were not extended to higher bank elevations. These cross se· tons were extended to both banks using cross sections surveyed in 1981, located upstream and downstream from a given 1982 cross section. The cross sections derived from the topograhic maps are only approximate because of the small scale (1:63,360) and large contour interval. Initial 'n' Values The derivation of 'n' values by R&M is discussed under the section entitled "Review of Previous Study" and are listed in Table 1. These values were used as initial values for refining the calibration. Control Points ADF&G has developed stage discharge relationships for all staff gages established on the mai~stem, side-channels or -7- I '' I .; 'J l ' ~ l ' j I ' ' ' j : I , I I sloughs (4). The discharges used in these relationships are those at the Gold Creek gage. All gages designated as mainstem gages were selected as control points to compare observed gage heights with the gage heights of corresponding discharges computed by the HEC-2 model. Lowever, during the calibration of the mod9l, some of these control points had to be ignored because of ~nconsistency be- tween the next upstream or next downstream control point. The control points used in the study are identified in Table 2. 0 Five of the ADF&G gages are the same as five of the eight gages used by R&M (gage No. LRX-9, LRX-24, LRX-28, LRX-35 and LRX-62, Table 2). The gage heights used by R&M at these gages were compared with those obtained from the stage-d .:.scharge rat- ing curves provided by ADF&G. The two set of values were slightly different at some locations.. For consistency with the upstream and downstream control points (ADF&G gages), the gage heights determined from the ADF&G relat.ionships were used. At the other three locations used by R&M, ADF&G data were not available. At these locations (LRX-4, LRX-5 and LRX-68, Table 2)? the data used by R&M, was used in this study. The ADF&G stage-discharge relationships are developed for dischrges ranging between about 8,000 cfs and about 25,000 cfs. To calibrate the model for higher discharge, R&M data (see Table 2) were used. -8- I I t I I I 'I I I I d I -J The observed gage heights for various discharges either taken from R&M data or the stage-discharge relationships deve- loped by ADF&G are given in Table 2. HEC-2 Model Set-up Multi-channels (sloughs and side channels) exist at a num- ber of cross sections (see Exhibit 2). As discussed under the section ent~tled "Review of Previous Study", R&M estimated a threshold discharge of 20,000 cfs above which flow will enter all the channels. This value is considered to be reasonable based on the available surveyed cross sections and is used in. the present study. Therefore, two data files were set-up for HEC-2. In one file, the option of artificial levees available in HEC-2 was used to restrict flows in the main channel (for discharges up to 20,000 cfs at Gold Greek). In the other file, the flow was allowed to exist in all channels (for discharges above 20,000 cfs at Gold Creek). Refinement of HEC-2 Model Calibration The HEC-2 model calibration made by R&M was tested for three discharge levels (9,700 cfs, 13,400 cfs and 17,000 cfs) below and three discharge levels (23,400 cfs, 34,500 cfs and 52,000 cfs) above 20,000 cfs. Because the above discharges are at Gold Creek, these were adjusted by the factors derived by R&M (discussed under the section entitled "Review of Previous study'~) for the correspond- ing discharges at various sections. T~e adjustment to the dis- charges for the reaches downstream of the confluence of the -9- I l t I .,~, I t ; ' ' ~ .,,_ ' . l!f ,,;! . \!I . '~~f I 1! ' <lj .. : II ) I (: ' susitna and chulitna rivers and the confluence of the susitna and Talkeetna rivers also were based on drainage area ratios. Table 4 shows the discharge in each study reach for a given dis- charge at Gold Creek. First HEC-2 run was made for 9,700 cfs using the 'n' values derived by R&M and the 107 river cross sections shown on Exhibits 1 and 2. One cross sections interpolated by R&M be- tween cross sections 43.0 and 44.0 also was used. R&M used this cross section to avoid critical depth at cross sections 4480. Exhibit 3 also shows a water surface profile computed by R&M based on the cross ;:5ections surveyed in 1981 and the correspond- ing profile computed using all surveyed cross sections and the refined 'n' values. The difference in the two profiles indi- cates the sensitvity of water surface elevations when new sur- veyed cross sections are introduced in the computations. This will be discussed further under the sections entitled "Discus- sion" and .. Recommendations" .. The refinement of thE. model calibration for 9, 700 cfs was continued by successively changing the 'n' values and the values of expansion and contraction coefficients until the observed water surface elevation at the control points are properly reproduced. The outputs indicated critical depth at cross sec- ton 18.1. A careful review of the locations of cross sections 18.0, 18.1 and 18.2 (Exhibit 2) indicated that steep slope starts at about half way between cross sections 18.1 and 18.0 and critical depth should not occur at 18.1. The river is wider -10- I 0 II at cross section 18.1 compared to its width at cross section 18.0. Therefore, a cross-section, 18.05, was interpolated be- tween cross sections 18.0 and 18.1, and the values of expansion and contraction coefficients ~erG also changed. This avoided the critical depth at section 18.1 A comparison of computed and observed water surface eleva~ ,_. ""1ons is shown on Table 2. Except in a few cases the two values match reasonably well. The difference in the computed and observed water surface elevation ~t cross section 28.0 is about ~.3 feet when using the observed gage height derived from the stage-discharge curve developed by ADF&G and about 0.6 feet when using the observed height given by R&M (see Table 2). The difference in the observed water surface elevation is probably because of judge- ment exercised by two different organizations in developing the stage-discharge curves. The 'n' values at this cross section and the n~xt upstream or downstream cross section had to be lowered to match th~ computed water surface elevaion with the observed value (see Table~:~. Further lowering of the 'n' values was considered inappropriate. At cross section 35.0, two observed water surface eleva- tions are available (Table 2), the computed elevation is about 0.1 feet higher than the R&M value and about 0.7 feet higher than the ADF&G value. The 'n' values in the reach are reasonab- ly low. Because t:he computed value was close to the R&M value, further adjustment to 'n' values was not made. Secondly, the -11- ; tl. :i '"' : ~! '~~ ' ~j ..,. ;~l ~ .(: ! !: ~~ ~~' ; ' 3' ., .~ :~ ,· . ~ -· .'c4 ; = . I • ~ . l • ( • i . '·j j ' 1 'i I. { ,, l I l l .. ;< l t ,, ·,, ;· l \,·I ; 1 I l j t j 1 :l ,: I :"1 '\ ! I i 1 1 I t l I :! : I i I i·-, ''r ~ : j r .: '! :l '·: ·i:! K ra I ' B I It Ii m ' -~ t i til I ~J ·" u ti i .. ·~ ~-' ,. ~ I I stage-discharge curve developed by ADF&G showed considerable scatter for 8,000 to 12,000 cfs discharge range (4). The model refinement for the discharges of 13,400, 17,000, 23,400, 34,500 and 52,000 cfs was continued essentially follow- ing the above procedures, that is successively changing the 'n' values. A comparison of computed and observed \V"ater surface elevations are given in Table 2. The final 'n' values are shown in Table 1 • In a few cases when a control point is not located on a surveyed cross section, the computed stages are interpolated from the values computed at the surveyed cross sections to corn- pare with the observed values. In gen ·· \ ·· 1, lower 'n' values were used for higher di schar- ges. Howev~r, in certain reaches of the river and also dictated by observed gage heights at the control points, some deviation was allowed. Therefore, Table 1 indicates higher 'n' values for higher discharges compared to the 'n' values for lower dis- chazges in a few cases. This situation is physically possible particularly at multi-channel cross s~~tions because at higher stage, side channels could exhibit higher roughness. The HEC-2 model was also applied for the discharges of 3,000, 5,000 and 7,000 cfs. Six control points were available from R&M for the discharge of 3,000 cfs" The model was cali- brated using these control points. The computed and observed water surface elevations are given below: -12- ft·· . . .... 11 .t; ft B ; i . H . ' ~~ m f~l VJ u ' j ra_ .l". ~ .• :•_1~ r. ' ' ; ;_L ·J~_- l' .. i It I I COMPARISON OF WATER SURFACE ELEVATION Discharge = 3,000 cfs Control Point 3 9 24 35 45 62 Computed (ft) 339.7 374.7 519.2 615.0 681.1 831.4 Observed (cfs) 340.2 375.1 519.1 614.7 681.4 831.9 The 8 n' values for 5,000 and 7,000 cfs were interpol&ted from the values for 3,000 and 9,700 cfs. The computed water surface elevations are given in Table 5. The computer input and output files for all discharges for which water elevations are given in Table 5, are provided as Appen- dices A through I. These appendices provide information on cross sections where the flow was comfined in main channel or allowed over the full channel width for different discharges. Stage-Discharge Rating Curves Stage-discharge rating curves at 74 locations, based on the water surface elevations given in Table 5, are shown on Exhibit 5 to 78. The locations were selected at all control points to provide comparison of observed and computed water surface eleva- tions, and upstream and downstream from the important sloughs. Smooth curves are drawn through the plotted points. Mainstem River Velocitx Me.an velocity at a given cross section are computed as part of the computations made by the HEC-2 model. These velocities, -13~ t ,!1 ., I •. ,· -~ll Jil I .• :f m lJl <l"' ,. .. ~ ~ .J "" t~j } ~:U ft.J ··~ ~- .,l it <·"· ·u ~ . II . . i I derived from the computer outputs given in Appendices A through Ir are summarized in Table 6. The velocities for locations between two surveyed cross sections can be interpolated from the table. Dicussion The HEC-2 :model provides an acceptable procedure for the computation of water surface profiles in a natural river.. How- ever, some assumptions involved in the model should be recog- nized. This will help in the proper interpretation of results provided by the model. The model assumes a uniform water surface elevation across a given cross section. Such a condition does not necessarily exist in a natural river especially at bends and multiple-chan- nel cross sections. Table 3 provides some idea about the magni- tude of difference between water surface elevations at a given cross section. At bends, the difference depends upon the radius of bend, river width and velocity. Even in a straight reach of a wide river some difference in water surface elevations between the left and right banks could exist because of oblique flow conditions • At a multiple channel cross section, reasonably accurate water surface elevations can be computed in two or three chan- nels by trial-and-error using HEC-2 if control point is avail- able in each channel. Since these data are not available for the present study, the procedure was not used. -14- At some multiple-channel cross sections, the side channels are connected to the main channel at some threshold discharges., A discharge at 20,000 cfs has been used for this purpose based on the initial calibration by R&M. However, this discharge could vary from cross section to cross section as can be seen from the discontinuity in a few stage-discharge rating curves (Exhibits 5 to 78) based on actual observations. The flow velocity computed by the model at each cross sec- tion is the average velocity over the entire flow area. Field observations indicate that at a multiple-channel cross section, the velocities are differents in various channels. This should be recognized while using the velocity data. RecoiTl!Ilendations Exhibit 3 shows a comparison of two water surfa.ce profiles for a discharge at 9,700 cfs. The first profile is computed by R&M and the second profile is computed by Harza using the re- calibrated 'n' values and additional cross sections surveyed in 1982. The difference between these profiles is about 5 feet near cross sections 18.1, 18.2 and 18.3 although the differences at other locations vary +0.5 to +2o0 feet. This difference is caused because the thalweg elevation at cross section 18.1 (sur- veyed in 1982) is about 3 feet higher than the elevation inter- polated between cross sections 18.0 and 19.0. R&M did not use cross sections 18.1, 18~2 and 18.3 in their calibration. There- fore, a lower surface profile resulted when using a lower thalweg. -15- 1····1. ,. ,, f '' fj ,......,,.f I The large difference in the two computed water surface profiles due to introduction of new cross sections indicates the necessity of additional cross sections if further refinement of water surface profiles are needed for any particular subreach. For the present study, additional control points (Table 2) were taken from the 1982 ADF&G study (4) and also the 1983 pre- lirninary data. The ADF&G study covers the discharge range of about 7,000 to about 32,000 cfs and the 1983 preliminary data which include the new control poiht (Table 2) cover the range of about 15,000 to about 32,000 cfs. Since the range of calibra- tion is between 9,700 and 52,000 cfs, the first set of data does not cover the high range above 32,000 cfs and the second set of data does not cover the low range below 15,000 cfs and the high range above 32,000 cfs. Therefore, it is recommended that river stages be observed at all mainstem gages to cover the entire range of calibration. Some of the mainstem gages could not be used in the cali- bration because of inconsistenc1 in the recorded stages when compared with the next upstream or downstream gage. The gages near Lane lough and at cross section numbers 56 and 57 Jre examples. It is likely that these differences are due to inac- curate designation of river mileage at some gages. In a rela- tively steep channel, a difference of +0.2 mile in a gage loca- tion could cause a significant difference in the water surface elevation. It is recommended that for any future refinement of -16- the water surface profiles, effort must be made to determine accurate river mileage of the gage locations. The number and locations of the surveyed river cross sec- tions between the confluence (of the Talkeetna and Susitna rivers) and the mouth of the Devil Canyon are adequate unless as discussed previously, further refinements of water surface pro- files for any partcular subreach are needed. However, at least five cross sections downstream of cross section 0~3 should be surveyed for more accurate water surface profiles of the river reach between the confluence and the Sunshine bridge. Obser- vation of river stages also will be ~aquired at these cross sections. Additional control points also are required at some multiple-channel cross sections. At least two staff gages should be established in each major channel of a cross section. Twenty additional control points are recommended as shown on Exhibit 2. -17- i~l fl li 1. 2. 3. 4. s. Reference R&M Consultant Incorporated, October 1981: Susitna Hydro- electric .Project, Hydrographic Surveys Closeout R~port, Task 2-Surveys and Site Facilities, Final Draft, prepared for Acres American Incorporated for submission to Alaska Power Authority, Anchorage, Alaska. R&M Consultant Incorporated, March 1982: Susitna Hydro- electric Project, Hydraulic and Ice Studies, Task 3- Hydrology, prepared with Acres American Incorporated for submission to Alaska Power Authority, Anchorage, Alaska. R&M Consultant Incorporated, December 1982: Susitna Hydro- electric Project, h1drographic Surveys Report, Task 2- Surveys and Site Facilities, prepared for Acres American Incorported for submission to Alaska Power Authority, Anchorage, Alaska. Alaska Department of Fish & Games, 1983: Susitna Hydro Aquatic Studies, Phase II, Basic Data Report, Volume 4: Aquatic Habitat and Instream Flow Studies. u.s. Army Corps of Engineers, Hydrologic Engineering Center, 1973: HEC-2 Water surface profiles, Programmers Manual; 1981: HEC-2, Water surface Profiles, Users Manual, Davis, California. -18- l I I I I I l ! . I 1 ,, ~.tl.J; U' } ·• !,. u II 1M I'~ .•} ~ . .. ' . '• .... ',.~ 1" A ~ • • j,:l< t ' • J "'•, • I • • I ~ ~ 4 i ' : ~ ' • 1 •• I': 'l-~ I ' 6. Chow, venTe, 1959: Open Channel Hydraulics, McGraw Hill Book Company, Inc., New York. 7. Limerinos, J.T., 1970: Determination of Manning Coeffi- cient from Measured Bed Roughness in Natural Channels, Water Supply Paper 1898-B, u.s. Geological Survey, Washington, D.C .. 8. Kellerhals, R. and Dale I. Bray, August 1971: Sampling Procedures for Coarse Fluvial Sediments, Journal of Hydraulic Division; ASCE, Vol. 97, No HY8, pp 1165-1180. -19- ·~ ·- . - . . ' ~· . ~ • • w ~,:-_:,;;_..._.._. ... ~~--...-----~~~.,;._-,._ ....: -~ ... -..;~ -· -....:..::..---"~ ..,,.;:,_,__,..-':.:~..:;::~ .,...,~_;,::;_~:;-.e~~,~~ ·:.~··:.~.c::.::.:;:-:::._.r.~.-__ ...:;::.:.::;.;~--..,,_., ___ .. ....;.-.... ;,;:-~ -.... _...,. _ _.-••• _.._._.. .. .JI,..jl.t~:~.,:-,:-.uu.U~.Al_;;.J~~JJ uo .. .ttltt:l :.-;;:~w n r·'nt ;u.~-.--: -7;~.~---,~:~~---~ -·~.---:"-:~-·~._.;:·;~~~-:;~~::~==;~ ..... ~.;~ ---~~""-~=-·-~--~ b.!._ s::: ~ l!ir~: ~ ~~ ~4:J ·. Section r>istance __!!2.:..__ (Mi1~s) _ .001 83,.90 .01 84.83 ,.02 ---ft~ bo ... ~~ .OJ 88.13 .G4 89.e3 .05 91 .. 63 .3 94.23 .4 94 .. 55 .5 94.92 .6 95.37 .7 95.76 .8 96.13 .9 96.61 1.0 97.02 1.1 97.31 1.2 97.62 2,.0 97.93 2.1 98~03 2.2 98.23 2.3 98.42 3.0 98.59 3.1 98.75 3.2 98.93 3.3 99.10 3.4 99.31 4.0 99.58 4 .. 1 99.75 4.2 99.94 4.3 100.17 4.4 100.28 5.0 100.36 6.0 100.96 7.0 101.52 8.0 102.38 9.0 103.22 9 .• 1 104.12 10.0 104.75 10.1 105.01 10.2 105.81 10.3 106.34 11.0 106.68 12.0 108.41 13.0 110.36 -~~ ~~_. ~~~..:; ~~~~.:t 9,.700 (cfs) R&M Harz a .060 .060 .. 060 .n6fi .060 .060 .. 060 .060 .060 .060 .. 060 .060 .060 .060 .060 .060 .060 .060 .060 .060 .040 .060 .025 .025 .025 ~025 .040 .025 .025 .025 .025 .025 .040 .025 .040 .. 025 .040 .025 .050 .045 .055 .055 .055 .055 .040 .030 .03{) .035 .055 .035 .055 .040 .055 .040 !;~~~ ~~..;~;we ,.~ .. ~~ ·-------·-----· .-........... ,.~-'"--~""'-"'.,._~ ......... -~........;..,_~_.._---~-----~ .. .-0 _;;_...,~--"'"'·-.....,.-·..,_,_ ............... "'·----"' ¥-- .t~--~ r:-~-~~ ·--~ ,.. __ ~:::;;. Tah1e 1 ..,.,~ '""·~ ,.,.,.,...~~ \1.~_:.;:;::;;.;.1 -,,...,.,..,;:...,.. MANNING's ROUGHNESS COEFFICIENTS ( 'n' VALUES) 13,400 (cfs 17,000 34, 50j-t'cfs) R&M Harza R&M R&-;.r-Harza .045 .040 o041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .,040 .041 .041 .045 .040 .o.:n .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .045 .040 .041 .041 .. 038 .045 .036 .040 .036 .041 .032 .041 .028 .035 .035 .035 .028 .035 .035 .035 .028 .035 .035 .035 .028 .030 .035 .035 .038 .028 .036 .030 .036 .035 .032 .035 .028 .030 .035 .035 .028 .030 .035 .035 .028 .030 .035 .035 .028 •. 030 .035 .035 .038 .028 .036 .030 .036 .035 .032 .035 .038 .025 .036 .025 .036 .033 .032 .035 .038 .035 .036 .025 .036 .033 .032 .035 .048 .036 .045 .038 .045 .038 .041 .038 .052 .048 .050 .046 .050 .042 .045 .041 .048 .046 .042 .041 ~ 052 .030 .050 .030 .050 .030 .045 .030 .025 .025 .025 .025 .,025 .02J .025 .025 e030 .030 .030 .030 .052 .030 .050 .030 .oso .030 .045 .030 .052 .040 .050 .040 .o5o .036 .045 •. 035 .052 .040 .050 .035 .. 050 .036 .045 .035 --k.;.:.~ ~ ,:;~ 52,000 (cfBi R&M Harz a .035 .035 .035 .035 .035 .035 .035 .035 .035 .035 .035 .035 .035 .035 .035 "035 .035 .035 .035 .035 .032 .030 .035 .035 .035 .. 035 .032 .035 .035 .035 .035 .035 .032 .035 .032 .035 .032 .035 .041 .038 .045 .OJR .038 .045 .030 .025 .025 .030 .045 .030 .045 .035 .045 .035 .~ ~.~W ::• ;}; -.. ...;..::__ ..-;.;..:,~i·.-.. -:.... ;.:---"~ ... .---.. •. .:I.. ... __ t.~~:'!;.u~ll:~~h""-'ll:l.:l 1. u.·.Mn .rnt.tl ---~ . ----. " -' -' ~--""'-~"--___ ,_"'-~----~-"-...... _._·-~...._.-__ ...,.. __ ... __ .-..;-_._,___........,_.~~---.-· -~-..... .><..,..,___.,_~-"'-_,_,.,.,;--,._ ... ~~.--,_~.--:,'.')>.:"~"'?· .: -•""·~--·~· "'''--•"--'""';;..;.~~~...-.....,~,~~~ -~-.,~ ~ "'''''::'1~-;..,'t"; &: ~ ......... ~, .... e;: Qt.:: ~.:::= ~ lL-,._~,-- ,,............. ~ ... .....,.."'"'~' <:~ ,~~-;...,."";: .. -~ t'~~ ~ ~--~:;; ~ ~;» ;.,...._,___, __ ,._... t~~:.;;"_,::..;l "-"--c;.·c;:;,._ :~.=;~~~ ~~~.r~~ k.,..,._,;-l.;,t;i:;.J* Table 1 (Cont'd) MANNING's ROUGHNESS COF.FFICIENTS (1 n' VALUES) Mannin~'s 'n' Values Section Distance 9, 700 ( cfs) 13,400 (cfs) 17,000 (cfs} 23,400 (cfs) 34,SOO {cfs) 52,000 (cfsl No. (Miles) R&M Harz a R&M Harza R&M Harza R&.M Hi'lrza R~-Harr,a R&M Harza --14.0 110.89 .055 .040 .052 .030 .050 .030 .oso .030 .045 .. 030 .045 .030 15.0 111.83 .045 .03A .043 .035 .041 .030 .041 .030 .036 .030 .036 .030 16.0 112.34 .040 .038 .03A .038 .036 .035 .036 .034 .,032 .032 .032 .032 17.0 112.69 .040 .030 .038 .034 .036 .032 .036 .030 .032 .032 .ol:?. .032 18.0 113.02 .040 .0.30 .038 .034 .036 .032 .036 .030 .032 .032 .0'32 .032 18.1 114.11 .045 .040 .040 .036 .032 .. 032 18.2 115.08 .045 .040 .036 .036 .032 .032 18.3 115.86 .045 .038 .036 .036 .032 .032 19.0 116.44 .040 .040 .038 .038 .036 .036 .036 .036 .032 .032 .032 .032 19.1 116.89 .040 .038 .036 .036 .032 .032 20.0 117.19 .040 .040 .. 038 .038 .036 .036 .036 .036 .032 .032 .032 .032 20.1 117.61 .040 .038 .036 .036 .032 .032 20.2 118.31 .040 .038 .036 .036 .032 .032 21.0 119.15 .040 .040 .038 .038 .038 .03fi .036 .036 .032 .032 o'032 .032 22.0 119.32 .030 .030 .029 .029 .027 .027 .027 .027 .024 • 024 .024 .024 23.0 120.26 .030 .025 .029 .025 .027 .025 .027 .025 .024 .024 .024 .024 24.0 120.66 .030 .025 .029 .025 .027 .025 • 02~/ .025 • 024 • 024 .024 .024 'lA 1 120.85 .050 .045 .035 .027 .024 .024 .. ., .... 25.0 121.63 .030 .050 .029 .. 045 .027 .035 .027 .027 .024 • 024 .024 .024 25.1 122.05 .035 .033 .030 .030 .028 .028 26.0 122.57 .035 .035 .. 033 .028 .032 .030 .032 .03'0 .028 .028 .028 .02A 27 .. 0 123.31 .035 .,030 .033 .028 .032 .030 .032 .028 .028 .028 .02A .028 28.0 i24.41 .035 .030 .033 .028 .032 .032 .032 .032 .028 .028 .. 028 .028 28.1 125.54 .030 .030 .032 .031 .028 .028 29.0 126.11 .035 .030 .. 033 .035 .032 .035 .032 .031 .028 .031 .028 .028 30.0 127.50 .038 .050 .036 .048 .034 .047 .034 .040 .031 .040 .031 .045 31.0 128.66 .038 .050 .036 .048 .034 .047 .034 .045 .031 .045 .031 .040 32.0 129.67 .038 .03A .036 .036 .034 .034 .034 .032 .031 .031 .031 .031 33.0 130.12 .036 .032 .034 .032 .032 .030 .032 .030 .029 .029 .029 .029 34.0 130.47 .036 .032 .034 .032 .032 .030 .032 .030 .029 .029 .029 .029 35.0 130.87 .. 036 .032 .034 .032 .032 .030 .032 .030 .029 .029 .029 .029 36.0 131.19 .036 .036 .034 .032 .032 .030 .032 .. 030 .029 .029 .029 .029 37.0 131.80 .036 .036 .. 034 .036 .032 .034 .032 .032 .029 .029 .029 .029 38.0 132.90 .036 .036 .034 .036 .032 .034 .032 .032 .029 .029 .029 .029 39.0 133.33 .036 .. 036 .034 .036 .032 .034 .032 .032 .029 .029 .029 .029 40,.0 134.28 .038 .040 .036 .036 .034 .034 .034 .034 .031 .031 .031 .031 41.0 134 .. 72 .038 .038 .036 .036 .034 .034 .034 .033 .031 .031 .031 .031 42.u 135.36 .038 .n38 .036 .036 .034 .034 .034 .033 .031 .031 .031 .031 4}.0 135.72 .040 .040 .038 .038 .036 .036 .036 .034 .032 .032 .032 .032 44.0 13n.40 .040 .040 .038 .038 .036 .036 .036 .03() .032 .032 .032 .032 45.0 136.68 .040 .040 .038 .038 .036 .038 .036 .036 .032 .032 .032 .030 46.0 136.96 .045 .038 .043 .036 .041 .034 .041 .034 .037 .031 .037 .030 Iii:: ~ ,...-.--,~ r---.. ··~:~ re::: ~-........__ ~-~~: ... ~ f/': .. : .• ~: r''~ ... ~ _........, r~ ~· :::J!1 ~'=··~ ' ~ ........... ~-""· ~.-=._., .... _; );.,;. __ ......., lii;.o~c .. c:.;..r Ii-i;:.~:;. .. <.;;:,.,. .•• ~...,..J l!~o. .... ,_...;::;::.:. • .......:t \..-;:,: "'~--"" ~:;,;;.; """=~ ""--'~ \;-.;...(l,,r.~' <:>~·---~ t~.'< Table 1 (Cont'd) MANNING's ROUGHNF.SS COEFFICIENTS ('n' VALUES) Mannin °s 'n' Values Section Distance 9,700 (cfs) 13,400 (cfs) 17,000 (cfs 23,400 (cfs 34, srm c cfs) 52,000 ( cf_s_) No. (Miles_) R&M Harza R&M Harz a R&M Harza R&M Harza R&M . Harza R&M Harza -47.0 137.15 .040 .038 .038 .036 .036 .034 .036 • 034 .032 .031 .032 .030 48.0 137.41 .040 .03R .038 .036 .036 .034 .036 .034 .032 .031 .032 .030 49.0 138.23 .040 .030 .038 .036 .036 .034 .036 .034 .032 .031 .032 .030 50.0 138 o48 .045 .. 035 .043 .035 .041 .034 .041 .033 .037 •. 030 .037 .025 51 .. 0 138.89 .050 .. 060 .048 .055 .045 .053 .045 .. 050 .041 .050 .041 .025 52.0 139.44 .050 .050 .048 .050 .045 .047 .045 .047 .041 .040 .041 .040 53,.0 140.15 .oso .035 .048 .035 .045 .035 .045 ,035 .041 .035 .041 .035 54.0 140.83 .055 .035 .052 .030 .050 .030 .050 ' .027 .045 o027 .045 .027 55.0 141.59 .055 .035 .052 .030 .050 ,030 .050 .027 .045 .027 .045 .027 56.0 142.13 .055 .045 .052 .030 .050 .030 .050 .030 .045 .030 .045 .. 030 57.0 142.34 .050 .055 .048 .045 .045 .041) .045 .035 .041 .035 .041 .035 58.0 143.18 .050 .060 .048 .055 .045 .055 .045 .045 .041 .04fi .041 .035 59.0 144.83 .050 .065 .048 .060 .045 .060 .045 .055 .041 .041 .041 .035 60.0 147 .. 56 .055 .060 .052 .055 .,050 .055 .050 .055 .045 .041 .045 .035 61.0 148.73 .055 .060 .052 .055 .050 .045 .050 .041 .045 • 04] .045 .035 62.0 148.94 .055 .060 .052 .055 .050 .oso .050 .045 .045 .041 .045 .035 63.0 149 .1.5 .055 .060 .052 .055 .050 .050 .050 .045 .045 .041 .045 •035 64.0 149.35 .055 .060 .052 .055 .050 .oso .oso .045 .045 .041 104 5 .041 65.0 149.46 .055 .060 .052 .055 .050 .050 .050 .045 .045 .041 .045 a041 66.0 149.51 .055 .060 .052 .055 .oso .050 .050 .045 .045 .041 .045 .041 67.0 149.81 .055 .060 .052 .055 .050 .050 .050 .045 .045 .041 .045 o04} 68.0 150.19 .055 .060 .052 .055 .050 .050 .oso .045 .045 .041 .045 .041 -1':. .......,_::._ ~ rc: ~ t::~ ~'"'"'"" ',--=:;::~.;:: ~·~--"-'~ r-r::: -..!.:!., ~~~ ~~: ..--...... -.._;.,..~i '---"'-!! !~-~ ·-ff:':: --~ .-........... ~ -~ r~ ~~ .. ~-' "'""-" t..-,...._.~__....-~ 4'~""""" kQ~~ """-~ \.,;..;;,;,..,;:Ut Table 2 COMPARISON OF OBSERVED AND COMPUTED WATER SURFACE ELEVATIONS . Gage Distance.ll Gage Heights (ft) for Indicated Discharges (cfs) r.ocation 9,700 13 400 17,000 23,400 34,500 (mi) Obs. COIDJ2• Obs. ComE• Obs'" c(~r Obs. ComE• Obs. Corny. ( 1) (2) T3) ( 4) (5"') ( 6 ) T7r TIT (10) TITT (12 sunshine 274.1 274.1 275.1 275.1 275.9 275.9 277.2 277.2 279.3 279.3 LRX-4V 99.58 348.6 349.5 350. =· 351.6 352.8 (348.1) (348.6) (349.5)AI (349.5) (350.5) (350.8) (352.0} (352.0) (352.9) (353.1) Mains tern 101.15 Wisker 363.1 363.2 363.7 363.9 364.3 364.5 365.1 364.8 Slough Talkeetna l02 .. 9o 375.6 375.8 376.3 376.7 377.1 377.6 378.3 378.9 Fishwhee1 LRX-9.:J.I 103.22 378 .. 0 378.0 379.0 378.6 379.A 3Al. 2 383.3 (378.4) (.378.1} (379.0) (379.4) (379.8) (380.3) (381.6) (381.8) (383.1)(383.4) LRX-10.2 105.90 402.1 402.2 403.1 403.1 LRX-10.3 106.40 407.6 406.8 408.3 407.7 LRX-11 106.68 409.2 409.3 410.1 410.2 LRX-12,. 108.41 423 .. 4 422<-6 424.3 423.7 Side Channel 111.50 448.7 448.7 449.0 449.5 449.4 449.8 449.8 450.6 Gash Cre:el\ Head Gash ..~.11T.1o ·453. 7 453.8 454 .. 3 454.5 454.8 455.1 455.5 455.8 Creek Side Channel Mains tam 112.30 455 .. 2 455.2 455.9 455.9 456.4 456.4 457.3 457.3 Slough 6A LRX""18 113.02 460.4 460.,7 461.4 461.8 461.9 462.4 462.8 463.2 . - -~-,._....,, "-----··----............. ~-----"----~.,.____,_ .. ~···-~--'""---~.- ~ •:,;:_:;_;;..li,l 52,000 Obs. fTm (13) ) 282.2 282.2 354.5 (354.6) (355.1) 385.8 (385.4) (386.2) Iii:: ,!(" :u..-:::. ~~ c"-= Gage Location DistanceJ./ (mi.) (1) (2) Curry Fish 120.60 Wheel LRX-2.11/ 120.:;66 LR};-28.J./ 124.41 LID:-29 126 ,..11 LRX-31 1Z8. 66 LRXt ... Jsl/ 130.87 LRX-40 134.28 LRX.-,.4slf 136:,. 68 LRX-50 138.48 LRX-51 138.89 Mainstem at 139.80 Slough 19 LRX-53 140.15 LRX-5~ 1~0.83 ':::~ ~~~~ ,..;::: __ _ ~~-'!,;..,~.~ . .,_,~ -~--.....:: ~-~~ ......._... """----'"-~""'" ~ ........ --,~ '~ L;;;_ _ _;,.,._; '!'!:*'~ '"~ p----. ~.~-·-__.;.; ~--~c,~ _, ~~-..l--~ .... :.:::.":14 Table 2 (Cont'd) ·-"'"~ ~:.~.;:t:.lllliili< i:;.;~f,:~ --·~' r...V-,;,_..:;~ 4~~~ .,...._._ \£."'.:.:-~~- COMPARISON OF OBSERVED AND COMPUTED WATF.R SURFACE ELEVATIONS Gage Heights (ft) for Indicated Oischarges (cfs) ~,70!1 13,400 11, non 23,400 34,sno Obs. ComE• Obs. ComE· Obs. ComE· Obs. ComE· Obs. ComE• TI> ( 4} {5) ( 6) T7T" (A) (9') (10) ( 11) (12) 521.8 521.9 522.3 522.6 523-.2 523.7 521.1 521.2 522.0 522.2 522.8 523.0 l:j24.4 524.1 525.4 (521.1) (521.2~ (522.0) (522.6) (522.9){523.2) {523.8) (524.3) (524.4) (525.4) ~53.1 554.4 554.2 555.2 555.5 556.1 557.1 556.8 558.1 (553.8) (555.0) (555.3) (555.7) (556.0)(556.2) (557.0) (557.0) (558.2) (558.1) 569.1 569.4 570.4 570.4 571.1 571.2 572.1 572 .o 595.6 595.3 596.7 596.2 597.4 597.1 598.3 598..2 616.7 617.4 618.0 618.4 618.7 619.1 619.8 620.5 621.6 (617.3) (617.7) (617.9) (618.7) ( 619 • 0) ( 619 • 4) (620.0) ( 620.3) (621.3) (621.6) 655.2 655.2 656.0 655.9 656.6 656.5 657.1 657.5 6R4.0 685.1 686.0 687.2 688.4 (684.1) (684.0) (685.2) (685.1) (685.9) (685.8) (687.0) (687.0) {6~8.4) (688.1) 702.5 702.7 703.6 704.3 704.7 705.1 705.5 706.2 707.4 706.9 708.2 707.6 708.9 708.3 710.0 709.8 719.6 719.8 720.5 720.7 721.1 721.3 721.8 722 .• 3 722.9 722.7 723.8 723.7 724.6 724.4 725.5 725.4 732.1 732.3 733.0 733.1 733.8 734.1 ~ ~~-~ ~~,» 52cOOO Obs. CornE• {13) (14) 527.2 ( 527.5) (527.2) 560.1 (559.8) (560.1) 623.6 (623.3) (623o3} 690.5 ( 690.0) (689.9) • • • 'W, ~ I C' !': ~ "· • • • 0 & \ ---------'----"'--.,..· \ ,. 'it ' ., • ... --· ----· ---......;.....--..... ,~_,_: .• ,-.~_,::_:_,-:·:~~'\7L.-:J.'.I., lie!: Gage Location (1) ~~- 1111ic:..::,;;;;, r.;,--,;; ;:.:. k__,;.,y Distance.ll (rni) (2) Maistem at 144.70 Slough 22 LRX-61 LRX-62.l/ 1.49.73 148.94 ....... ~ • .J.-..,. .. -~--···-=-..... .::::.:.;..,.............,..:~~~~-::::;:~~.....,;;;...,...~-::c.:;.·.~-:--'---··.·_.,.._ --~~---.~ ~-~-~-,,. ,.; • ...::~--~ ~..::. ,;;.~ -....... _--. -... _.._....,...._.~;;.-. ~.as.i~.:....J.J.l},"--~-:-~ U i.CUA::_ta..tfl ~;-~ ~·~-· -~. :..~~::.: .~~:..'"'""'~;.>~,t!;.i'J;-~;>·-"'"-.· (?:; -~~ ~-....... ..:.~.a.;.• ~ ~ .\L;,:,_."_.;...,,...;;.a; ~-;;.~. ·~-·-'i :;:,'" :--*>\ "'~-~---"" ... ~ -~~ <.:.-.. ~:.,;. 'fable 2 (Cont.' d) ,,_ _ .... __,,., \..;.~-::-:::-:-~; ... ~ --·~ ~~-~ .o:~·:t l..;:r;:~~ COMPARISON OF OBSERVED _'\NO COMPUTED WATER SURFACE ELEVATIONS ~ ' . . ., ... -~ """~ fW~ ~'if.··..:--= ·~ ~'c.:::::2,. ·--.,.._,.. Gage Heights ( ft) for Indicated Discharges ( cfs) 9.1DO 13,400 17,000 23,400 34,500 """o-=-b-s-.--Comp. Obs. Comp. ~ Comp. ~ Camp. Obs. Cornp. (3) (4) (5) (n) C7l (8) <q> ClO) Cll> (12) 784.8 785.0 786.6 786.1 787.3 787.4 788.3 787.5 834.2 834.7 835.1 835.6 83f:.3 83'6. 7 836.5 836.n 837.3 837.1 R38.7 838.5 841.0 ~~_:_,; ~ ='='-'" ,l!IJ 52,000 obs. Comp:. (13) (141) 843.0 • 835.4 (835.4) (B35.U (835.9) (836.4} (837.5}(837.5} (838.3) {838.0) (840.7) (840.8) (843.9) {844.2) 852.1 852.8 854.0 855.8 858 .• 8 LRX-68.2./ 150.19 851~0 (851.4) (850.6) (852.2) (851.8) (852.9) (852.8) (854.1) (854.0) (856.0) (855.8) (859.0) {858.7) Distance from mouth of the river. Staff ga~ns used by R£M in Illodel calibration Staff gages used by R&M in model calibration and for which stage-discharge relationships also are available from ADF&G. Gage heights paranthesised, are either the observed or COJnputed values by R&M. ·~-::~;--::-···~-"'""""""'''-""'""T"Y'-~~·"·-"'""'""' r ;~ . iJ 1 ;~ I I I '. j r1 I . J Station .Numbers LRX-4 LRX-7 r.RX-16 LRX-31 LHX-36 LRX-39 LRX-42 LRX-43 I.RX-44 LRX-4A LRX-52 LRX-53 LRX-54 LRX-55 J:.".X-4 LRX-7 LRX-16 LRX-28 LRX-29 LAA-31 LRX-36 LRX-39 LRX-42 LRX-43 LRX-44 LRX-47 LRX-48 LRX-53 LRX-55 Table 3 VARIATION IN WATER SURFACE ELEVATION BETWEEN CHANNELs.l/ AT A CROSS SECTION Date of Flow Survey ( cfs) 10/4/80 10/6/80 10/10/80 10/30/80 10/36/80 10/28/80 10/20/80 10/17/BO 10/17/80 10/20/80 10/14/80 10/24/80 10/14/80 10/24/80 10/23/80 8/31/81 8/31/81 8/31/81 8/31/81 8/31/81 8/31/81 9/1/81 9/1/81 9/21/81 9/1/81 9/1/81 9/1/81 9/1/81 9/l/81 9/1/81 9800 9380 9695 2400 5525 5400 7230 7350 7350 7230 7290 6420 6420 6420 6270 223100 223:00 22300 22300 22300 22300 211010 21100 2110() 2110Cl 21100 21100 21100 21100 ,• Flow Less Than 10,000 cfs Water Surface Elevation (ft.} Ma1n Channel S1de Channel(s} Comments 350.4 364.6 455.2 594.1 619.0 645.6 668.7 670.9 679.9 691.7 713.8 722.2 731.8 742.6 348.2, 350 9 365.7 455.5 592.6, 593.7 618.5 644.7, 642.9 666.8 (slough) 667.8 673.7 680.8 689.7 (ponded) 716.3 724.0 733.5 739.9 Frazil ice accum.; 10' wide shore ice. Shore ice; ice floes. Variation of 0.4' in water surfac,· across main channel Frazil ice Small side channel w/flowing water Flow Greater than 21,000 cfs 351.4(M) 367.6(L) 457.4(L) 557.7{M) 572.4(R) 598.2{R) 622.4(L) 648 .. 5(R) 672.2(R) 673.5(R) 683.8{R) 693.7(M) 695.3(R) 725.4(R) 743.6(LB) 744.9(RB) 351.5(L), 352.6(R)1J 368.0{R) 457.6(R), 455.q(M.SL) 457. 3( RSL) 556.4(L), 557.2(R) 574.0(L.SL) ponded water in left slough 594.8{M.SL), 593.0(L.SL) 621.6(R), 647.0(L) 646.l(L.SL) 669.5(LSL) 673.5{M.SL), 674.8{LSL) 681.8{M.SL) 682.8(L.SL) 69l.l(L.SL) nCl2.7(L.RL) 725.l(L.SL) 743.l(L.SL) Flowing ater in left slough .. !/ Source: R&M Report \2, Tables 4.5 and 4.6) 11 Abbreviations L = Left Channel; R -Right Channel; M -Middle Channel; SL -Slough; [ l ' I _j ' ...... l l_, i J . u J y I Cross From 001 1.1 3.0 24.0 51.0 62.0 Table 4 RIVER REACHES AND CORRESPONDING DISCHARGES Gold Creek Discharges ( cfs) Sections 9,700 13,400 17,000 23,400 34,500 To Discharges in River Reach (cfs) 1.0 17,000 23,480 29,790 41,020 60,470 2.3 13,930 19,240 24,405 33,610 49,540 23.0 9,990 1~,880 17,508 24,107 35,540 50.0 9,700 13,400 17,000 23,400 34,500 61.0 9,540 13,179 16,720 23,000 33,910 68 .. 0 9,140 12,626 1n,Ol9 22,045 32,500 52,000 91,140 74,670 53,5(;6 52,000 51,109 48,984 l ! ! i 1 ! . l I < ~. #!h -Y· ,. ·····.;;;;;;·--··-·, ~-;-;::·· , ... ·:. ·~. ·-=.-·-'···''__c, __ .~_~-:: ·-=--.,:;.,::·-·.:.·.~·.:.: -.~ < -L~~ --~~,;;:,.."""",,::~~"-=c"", ,. ·'·"'~·'-"'·~: .. ~0<·" "-«···'""'·"'"''·"·"-~. ·:: ••...•• ~. ·····-' II , ... ·c ~ .... < .__., Cross y--_:.:.::__ L;""~' Section 0.001 0.01 0.02 0.03 0.04 0.05 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 2.0 2 .. 1 2.2 2.3 3.0 3.1 3.2 3.3 3.4 4.0 4.1 4.2 4.3 4.4 5.0 6.0 7 .o.. a.o 9.0 9.1 10.0 10.1 10.2 10.3 11.0 t;:.~ River Mi_!eage 83.90 84.83 86.93 88.13 89.83 91.63 94.23 94.55 94.92 95.37 95.76 96.13 96.61 97.02 97.31 97.62 97.93 98.03 98.23 98.42 98.59 99.75 93.93 99.10 99.31 99. 5.8 99.75 99.94 100.17 100.28 100.36 100.96 101.52 102.38 103.22 104.12 104.75 105.01 105.81 106.34 106.68 !;." :: ~ ~,_, k ---·-' r~ lL ...... ~~ l. Table 5 i~ WATER SURFACE ELEVATIONS f~ ' t!'=Yf :lilt;,._~ G ... ,,_,_,,;.. Water Surface Elevations (ft,msl) for Indicated Discha~ge (cfs) 3,000 5,000 7,000 9,700 13,400 17,000 23,400 272.1 272.7 273.3 274.1 275.1 275.9 277.2 276.fi 278a2 279.0 281.4 281.6 282.3 284.8 281.7 282.8 283.5 285.5 265.7 286.4 288.5 285.1 286.0 286.4 288.0 288.1 288.6 290.4 291.4 292.2 292.7 294.0 294.1 294.5 295.9 298.7 299.4 299.7 300.9 301.0 301.3 30.2.5 314.3 315 .. 3 315.7 316.7 316 .. 7 317.1 318.2 316.1 317.0 317.5 318.7 318.8 319.2 320d3 317.3 318.5 319.1 320.7 320.8 321.2 322.4 319.2 320~8 321.5 323.4 323.6 324.2 325.5 323.5 324.3 324.8 326.3 326.5 32fi.9 328.2 326.5 327,2 327.6 328.8 328.9 329.3 330.4 330.5 331.1 331.4 332.4 J32.5 332.8 333.6 332.0 332.9 333.4 334.6 334.7 335.0 335.9 332.9 333.9 334.5 335.7 335.8 336.2 337.2 335.0 335.7 336.1 337.3 337.4 337.7 339.0 336.7 338.0 338.3 339.3 339.4 339.7 340.9 337.1 338.3 338.7 339.7 339.8 340.1 341.3 337.7 338.9 339.3 340.5 340.5 340.9 342.3 338.5 340.0 340a5 342.5 342.7 343.5 345.4 339.7 341.2 341.8 344.1 344.5 345.3 346.9 340.9 342.1 342.7 344.6 345.1 346.0 347.5 343.4 344.1 344.6 345.2 345.8 346.8 348.0 344.8 345.5 346.0 346.1 346.8 '347.7 348.6 345.9 346.4 346.9 347.2 348.0 348.8 349.8 347.1 347.5 348.0 348.6 349.5 350.3 351.7 351.0 351.4 351.7 351.9 352.6 353.2 354.3 351.9 352.5 352.8 353.0 353.8 354.4 355.5 352.5 353.1 353.5 353.8 354.7 355.5 357.0 353.1 353 .. 9 354.2 354.5 355.5 356.3 357.9 356.5 356.9 357.2 357.4 358.0 358 .• 5 359.6 360.2 360.9 361.3 361.9 362.7 363.3 364.4 363.1 364.0 364.6 365.3 366.5 366.6 368.2 370.2 371.2 371.7 372.4 373.4 374.0 375.1 374.9 376.2 376.9 378.0 378.6 379.8 381.2 381.9 383.0 383.7 384.9 385.8 386.6 387.7 391.1 391.6 391.8 392.2 392 .. 2 392 .• 8 393.6 393.5 394.2 394.6 395.1 3€}5.3 395.8 396.6 399.7 400.2 400.8 401.4 401.7 402.2 403.0 403.8 404.9 405.4 406.0 406.3 40n.8 407.7 406.3 407.4 407.8 408.,3 408.7 409.3 410.2 'le!!~} ~ --d _____ _,__,;...;' .. :.....>¥~ '~ ~..:;~.:;;:-~0!. 34,500 279.3 291.7 294.1 294.9 298.8 304~7 318.7 321..6 323~9 327.0 329.6 331.€} 334.8 336.9 338.4 340.3 342.1 342.7 344.1 347.1 348.4 348.9 349.4 350.0 351.1 352.9 355.3 35fi.n 358.2 359.0 360,8 365.6 369.5 376.6 383.3 389.7 395.0 397.9 404.2 409.0 411.5 ~ ~~ .... ~ 52,0Q.Q 282.2 292.4 295.3 296 0 3 300.3 305.9 319.7 322.7 325.0 327.8 330.4 332.6 335.4 337.7 339.2 341.0 342.9 343.6 345.0 347.9 349.1 350.0 3!:?0.8 351.6 352.8 354.6 356.7 358.0 359.7 360.3 362.1 367.3 371.0 378.4 385.8 391.8 396.1 399.4 405.6 410 •. A. 413.2 ~; ~,:~~ ~~~ ·1.~!"7-=-~ .... ~.;.... .... __ ,,.~, ~~ ~:~.:,.~ Cross Section 12.0 13.0 14.0 15.0 16.0 17.0 18.0 18.1 18.2 18.3 19.0 19.1 20.0 20.1 20.2 21.0 22.0 23.0 ?4.G >.~.1 25.0 25.1 26.0 27.0 28 0 28.1 29.0 30.0 31.0 32.0 33.0 34.0 35.0 36.0 37.0 38.0 39.0 40.0 41.0 42.0 " --"~~--...,_,._':C..~~"~ .\:L.. .• , ;......._ \.~ ·-···~~ ~ tu.....-~~ -~"'" '"·-· '-;>;;. -~ .... '-""" Table 5 (Continued) WATER SURFACE ELEVATIONS .-.. ~~ .... <1-. - ~ ... ;~ .. "'---.. ~-.--.. .--:-.. -· _.;.~---~• ... .;~.-.:.~A :'h...LLL.U'bJ:, :rn.t.« :'" .... -::.:. _, -::-•-:::t ·--~·.J. ...... ---··-.. ,..., .... ~ .z¥-~-~~ Water Surface Elevat~ons (ft,msl) for Indicated Discharge_Lcfs) River Mi1ea~ 3,000 5,000 7,000 9,700 _!3,400 17,000 23,400 34,500 52,000 108.41 419 .o 419.7 420.4 420.8 421.7 422.6 423.7 425.6 428.0 110.36 433.2 434.3 435.6 436.2 437.6 438.1 439.6 441.5 444.9 110.89 441.3 44.2. 0 442.4 442.9 443.4 443.9 445.0 446.7 449 .. 3 111.83 450.2 451.2 451.6 452.1 452.6 452.9 453.7 454.9 456.3 112.34 453.4 454.2 454.8 455.4 456.3 456.6 457.7 459.0 460.8 112.69 457.6 458.1 458.6 459.0 459.9 460.4 461.1 462.4 463.9 113.02 459.1 459.7 460.2 460.7 461.8 462.4 463.2 464.9 466.6 114.11 471.9 472.8 413.4 474.2 474.5 475.3 476 .o 477.0 478.9 115.08 477.0 478.1 479.1 480.2 481.2 481.8 482.9 484.2 486.1 115.86 480.4 481.6 482.5 483.9 484.7 485.5 487.0 488.6 490.9 116.44 484.3 485.1 485.7 486.8 487.6 488.5 490.1 491.6 494.2 116.89 490.7 491.4 492.1 492.7 493.5 494.0 495.5 496.8 499.0 117.19 492.0 493 .• 0 493.9 494.8 495.8 496.4 497.9 499.0 501..0 117.61 497.8 498.7 499.4 50fl.1 501.0 501.5 502.5 503.5 504.9 118.31 502.1 503.3 504.1 504.8 505.5 506.1 507.2 508.2 509.8 119.15 506.0 507.3 508.3 509.2 510.2 510.9 512.2 513.5 515.7 119.32 508.9 509.8 510.5 511.5 512.3 512.9 514.0 515.3 517.3 120.26 518.1 518.8 519.3 519.7 520.4 520.9 521.8 522.9 524.6 120.66 519.2 520.1 520.7 521.2 522.2 523.0 524.1 525.4 527.2 120.85 520.0 521.2 522.0 522.7 524.0 524.4 525.4 526.8 529.8 121.63 530.9 531.4 532.0 533.2 533.8 533.9 534.6 537.8 539.6 122.05 532.5 533.1 533.7 534.8 535.5 535.6 536.7 539.6 541.7 122.57 535.6 536.4 536.9 537.6 538.2 538.9 540.1 542.0 544.2 123.31 540.2 541.3 542.0 542.8 543.3 544.4 545.5 547 .. 2 549.4 124.41 551.6 552.7 551.6 554.4 555.2 556.1 556.8 558.1 560.1 125.54 563.6 564.3 564.9 565.3 566.0 566.8 567.6 568.3 570.1 126.11 567.5 568.4 56'R. 8 569.4 570.4 571.2 572.0 573.1 574.9 127.50 584.7 585.6 586.0 586.7 587.3 587.7 598.0 5AQ.2 5112J.8 128.66 592.0 593.3 594.3 595.3 596.2 597.1 598.2 599.6 601.4 129.67 604.0 604.6 605.2 606.1 607.0 607.7 608.4 610.0 611.8 130.12 610.6 611.3 6:u. 1 612.2 613.0 613.5 613.8 614.6 615.9 130 .. 47 614.1 614.7 615.2 615.7 616.6 617.2 fil7.9 619.1 620.4 130.87 615 .o 616.0 616.6 617.4 618.4 619.1 620.1 621.7 623 .. 6 131.19 6D6.4 617.1. 617.8 61R.9 620.2 621.0 622.4 624.2 626.6 131.80 625.1 626.0 626.5 627.1 627 .a 628.1 628.9 629.4 630.4 132.90 637.0 637.7 638.2 63R.9 640.0 640.7 641. fl 643.4 645.6 133.33 644.5 645.1 645.4 645.9 646.4 646.7 647.4 648.2 649.7 134.28 653.1 653.8 654~4 655.2 ti55.9 fl56c5 f157.5 658.6 660.4 134.72 657.9 658.6 659.2 659.9 660o6 661.2 662.3 663.6 665.8 135.36 667.4 668.0 668.4 668.8 669.4 669.8 670.4 671.5 672.8 ,:.,;.: ~~ (~ -'""'-~----~·-·--···-, ....... ~-~-· .... ·-·~·~ ,'f ........... ;:: ~._---0 --......... ·-----~~-··""-"~~itwl: :u « ,. owe ww .... t a a .,... ~ ·»HW • a IIBlt.t!l r nrn mr•• J IC:' l ~"'''=~ i, Cross Section 43,.0 44.0 45.0 46.0 . 47.0 48.0 49.0 50.0 51,0 52.0 53.0 5~~. o 55.0 56.0 57.0 58 w 0 .. 59.0 60.0 61.0 62.0 63.0 64.0 65.0 66.0 67 .o 68.0 ~. .. ' ·- River Mileage 135.72 136.40 136.68 136.96 137.15 137.41 138.23 138.48 138.89 139.44 140.15 140.83 141.59 142.13 142.34 143.18 144.83 147.56 148.731 148.94 149.15 149,35 149.46 149.51 149.81 150.19 ,,...._ .. ------fC...:::.-~:::::::3 :;,.,.._._ '"' Table 5 (Continued) WATER SURFACE ELEVATIONS ---<-·--··-~· ·--""" ·---~·---.,. ·~~~~~~'i.~;.o;~),,_;;";~-~ ......... -~ ~:·= -..,_. ,1-:j e:--~ '""'~~-· .. ~-~ -~-l ~~-"·"'"""'" .. :,.;..( ·~ .,._,.. ... ~.~ .... -.;-:-_-.:..~ Water surface Elevations ( ft,msl) for Indicated niscnc.!-~e C.s_~s) 3,000 5,000 7,000 9, 700 13,400 17,000 23,400 .2_1,500 52,000 66854 669.4 670.2 671.2 672.1 672.7 673.8 675.3 676~9 678e8 679.6 680.2 681.2 682.2 683.0 684.2 685.4 687.4 681.1 682.2 683.0 684.0 685.1 686.0 687.2 688.4 690.5 684.1 685.1 6A5.9 686.9 687.9 688.8 690.2 691.7 694.1 687.5 688~6 689~3 690.4 691.3 691.9 692.9 694.2 696.3 689.8 690.9 691.7 692.9 693.9 694.6 fi95.5 697.0 699.1 698.6 699.6 700.2 700.9 702.7 703.4 704.3 705.2 706.6 700,2 701.3 702.0 702.7 704.3 705.1 706.2 707.3 708.6 705.4 706.0 706.5 706.9 707.6 708.5 709.7 711.4 711.7 713.0 714.4 715.8 717.1 717.8 718.2 718.6 719.5 720.1 719.9 720.8 722.1 722.7 723.7 724.4 725.4 726.5 728.8 730.2 730.8 731.3 731.8 73.2. 3 733.1 734.1 735.8 737.6 740.7 741.6 742.2 742.9 743.4 743.9 744.3 745.3 746.8 749.5 7 50.2 ?50.5 751.4 751.4 752.1 753.2 755.0 75fJ.9 751.'7 752.7 753.1 754.2 754.4 755.0 756.0 757.8 759.9 762.4 763.5 764.1 764.8 765.7 766 .• 2 766.2 767.9 769.2 783.0 784.3 785.4 786.8 787.8 789.2 790.4 791.2 792.3 816.4 817.5 818.5 819.5 82G.6 821.6 823.4 823.8 825.8 828.7 830.3 831.3 833.1 834.3 834.8 836.4 838.7 840.5 831.4 832.9 833.7 835.4 836.6 837.1 838.5 841.0 843.0 834.4 835.6 836.4 837.9 839.0 839.7 841.0 843 .. 2 845.2 836.2 837.6 838.5 839.9 841.1 841.9 843.2 845.4 848.0 839.0 840.0 840.6 841.9 84259 843.5 844.7 847.0 850.0 842.3 843.0 843.6 844.5 845.2 845.8 846.R B4B.5 850.9 845.7 846.8 847.5 848.7 849.6 850.2 851.1 852.4 854.7 847.3 848.6 849.5 851.0 852.1 852.8 854.0 855.8 858.8 '~ .:-~:,, f-.. ·"'"',_,.,,..,._ .. l~ Cross Section 0.001 0.01 0.02 0.03 0.04 0.05 0.3 0.4 0.5 0.6 0.7 o.8 0.9 1.0 1.1 1.2 2.0 2.1- 2.2 2.3 3.0 3.1 3.2 3.3 3.4 4.0 4.1 4.2 4.3 4.4 5.0 6.0 7.0 8.0 9.0 9.1 10.0 10.1 10.2 10.3 11.0 f-l. ~ I. ., River Mi1ea~ 83.90 84.83 86.93 88.13 89.83 91.63 94.23 94.55 94.92 95.37 95.76 96.13 96.61 97.02 97.31 97.62 97.93 98.03 98.23 98.42 98.59 98.75 98.93 99.10 99.31 99.58 99.75 99.94 100.17 100.28 100.36 100.96 101.52 102.38 103.22 104.12 104.75 105.01 105.81 106.34 106.68 IIIIIJillliii l . lllil':!!llllll ~ ~ ~ .L., .. .4: Table ii MEAN VELOCITIES ~ ,;:_.;;:;ga t:;::;:;;:;;;l "'· . ~-,.,..,-~ =;;.~-·-!.;;:'.~ Mean Velocities (ft,msl) for Indicated Discharge (cfs) .2..t_O.OO 5,000 7,000 9,700 13,400 17,000 23,400 1.5 2.2 2.7 3.4 4.1 4.6 5.4 l.n 2.1 2.6 2.7 3.7 4.3 4.7 .9 1.1 1.3 1.3 1.7 1.9 2.0 1.3 1.7 2.2 2.1 2.8 3.3 3.3 1.0 1.4 1.7 1.8 2.4 2.9 3.2 1.2 1.5 l.q 1.8 2.4 2.8 2.q 1.4 1.7 2.1 2.2 2.9 3.4 3.6 1.3 1.6 2.0 2.0 2.fi 3.0 3.2 1.3 1.7 2.1 2.0 2.7 3 .. 1 3.2 2.2 2.4 ~.8 2.4 3.2 3.5 3.3 1.6 2.0 2.4 2.1 2.7 3.1 3.0 1.3 1.7 2.1 1.9 2.6 3.0 3.0 1.3 1.7 2.0 1.9 2.6 2.9 3.0 1.0 1.3 1.5 1.5 2.1 2.4 2.7 1.3 1.5 1.8 1.7 2.3 2.7 2.9 1.4 1.8 2.1 2.1 2.8 3.2 3.0 1.3 1.5 1.9 1.9 2.6 "\ .... 3.2 .:JoU 1.0 1.2 1.5 1.6 2.2 2.6 2.8 1.6 2.1 2.8 3.3 4.5 5~3 5.7 2.5 3.2 4.1 3.9 5.2 5.4 4.3 1.6 2.0 2.4 2.3 3.1 3.4 3.3 4.0 3.4 3.7 2.4 2.8 2.8 2.7 3.0 2.9 3.0 3.0 3.2 3.0 3.1 2.1 2.2 2.5 3.2 3.4 3.2 3.4 2. J 2.7 3.0 3.8 4.0 4.0 4.3 3.6 4.6 5.0 5.3 5.1 5.0 4.fi 2.5 2.9 3.5 4.2 4.1 4.0 3.7 1.3 1.8 2.3 2.8 3.1 3.4 3.fi 1.8 2.5 3.1 3.9 4.1 4.1 3.7 4.7 4.8 5.3 6.2 5.2 4.9 4.4 2.4 3.2 4.0 5.1 5.7 6.1 4.9 2.5 2~9 3.2 3.6 3.q 4.2 3.9 3.5 4.1 4.5 4.8 4.4 5.5 4.6 1.9 2.5 3.1 3.8 4.3 4.7 5.4 1.6 2.1 2.6 3.2 4.0 4.4 5.1 5.1 1.4 4.7 4.4 4.9 5.2 5.7 1.4 2.1 2.7 3.3 4.5 4.9 5.6 2.8 3.2 3.7 4.1 5.3 5.6 6.1 2.4 3.0 3.4 3.8 4.8 5.3 6.2 3.7 3.5 3.q 4.2 5.3 5~7 6.3 2.1 2.4 2.9 3.6 4.5 5.0 5.9 t, .. ~ _..., ,,..._,._:;w F·~ ..... ,_"~~ ..... :.;;:.;! ,!';.:~ .. :~:'::.~ .. : __ ;'i 34,500 52,000 6.3 7.2 3.0 3.6 1.6 2.2 2.7 3.6 3.2 3.8 2.6 3.3 4.6 5.4 3.5 4.1 3.3 4.0 3.2 3.8 3.1 3.9 2.9 3.5 3.2 4.2 3.1 4.1 3.1 3.9 3.1 3.9 3.6 4.8 3.2 4.0 5.3 6.3 3.8 4.6 3.3 4.3 3.1 4.0 3.4 4.1 3.7 4.3 4.8 5.4 5.0 5.1 4.0 4.3 4.2 4.9 3.9 4.2 4.7 5.3 5.3 6.4 4.5 5 .. 2 5.1 5.8 6.5 7.9 6.0 7.2 6.1 6.8 6.4 7.5 6.7 7.6 7.3 8.9 7.2 8.2 7.0 8.5 . ; . ' ... __. ·-· 4! - -_J -" ' ...._,... • [__._ . ' ' ... • "' M •.::: .a .. _...;--~-.,~-~~~--~~!~ ,..._&.._~~-~.~:::_.,c-~-;__~. ~~:'$_::. _ ~ ;.:-.;,;. ~~-y-n 'Y-i~3~~~:~~~~.o.~~=-~-~'7-":::~ .. -~_:::~--:.;~!; ~ -~=:~-~---~\~~~~ .. ::~~~.;:.;:~ . ......_,~;;..;.!=-.:-. • ..... 1. '"-... --'... -• -a~-.. _ _.. ..;,........_.._.,.,.:""""'"""'"""""",;_,~~:.t,i"": ... .t.."l:t.l..t4,-UJi. :.,m,t4 r--lk."·· '-~ Cross Section 12.0 13.0 14.0 15.0 16.0 17.0 10.0 18.1 18.2 18.3 19.0 19.1 2.0 .. 0 20.1 20.2 21 .. 0 22.0 23.0 24 .. 0 24.1 25,.0 25.1 26.0 27.0 28 0 28.1 2.9 .o 30.0 31.0 32.0 33.0 34.0 35.0 36.0 37.0 38.0 39.0 40.0 41.0 42.0 .-... ·-"' River Mil('!(:ige 108.41 110.36 110.89 111.83 112.34 112.69 113.02 114.11 115.08 115.86 116.44 116.89 117 .. 19 117.61 118.31 119.15 119.32 120.26 120.66 120.85 121.63 122.05 122.57 123.31 124.41 125.54 126.11 127.50 128.66 129.67 130.12 130.47 130.87 131.19 131.80 132.90 133.33 131!.28 134.72 135.36 l ~ ~ ~ L, ... ""'"'"~~~~ .. ~-~-..... ;\~.-......... ~~~~~ ........ --~--..:.....,.....~~----"·""~·--,....._ ... ,....~. ··--·"""-·--~----..-.-.-. ~ ji.,......;.~ ~ Table 6 (Continued) MEAN VELOCITIES ~ 1=··4 --..... t• .• ""'! Mean Velocities (ft,msl) for Indicated Dischar~e · ( cfs) 3,000 5,000 7,000 9,700 13,400 17,000 23, 400_ 2.1 2.8 3.3 4.2 4.8 5.2 6.1 2.4 3.1 3.4 4.2 4.6 5.4 6.1 3.9 4.4 4.8 5.3 6.1 6.5 6.4 1.6 1.9 2.4 2.9 3.7 4.4 5.2 2.5 2.9 3.4 3.9 4.2 4.8 5.0 2.4 3.2 3.7 4.3 4.4 4.9 5.6 1.4 2.1 2.6 3.3 3.7 4.3 5.3 1.7 2.2 2.6 3.1 4.1 4.3 5.2 2.1 2.7 3.1 3.4 3.9 4.5 4.9 1.9 2.5 2.9 3.2 4e0 4.6 5.2 3.3 3.8 4.4 4.5 5.3 5.7 6.1 2.3 3.0 3.4 4.0 4.6 5 .. 2 5.1 2.2 2·. 9 3.4 3.7 4.0 4.4 4 .. 4 4.5 4.1 4.0 4.0 4.1 4.5 4.5 1.5 1.9 2.3 2.7 3.3 3.8 4.4 4.9 4.6 4.9 5.3 6.0 6.1; 7.0 3.4 4.3 4.8 5.0 5.6 6.2 6.7 2.9 3.3 3.9 4.6 5.2 5.8 6.4 1.8 2.5 3.2 4.1 4.9 5.5 6.6 8.4 8.5 9.1 9.9 9.3 10.8 11.9 1.6 2.1 2.3 2.0 2.3 2.9 3.3 1.9 2.6 3.0 3.2 3.8 4.7 5.3 2.7 3.3 3.9 4.4 5.3 5.8 6.6 2.7 3.4 4.0 4.fl 5.7 5.9 7.0 7.1 6.5 6.5 6.5 6.6 6.4 6.3 1.9 2.4 2.7 3.3 3.9 4.1 4.7 4.0 4.3 s.o 5.8 6.0 6.4 7.4 1.8 1.9 2.2 2.3 2.5 2.7 3.3 2.1 2.5 2.9 3.4 4.1 4.7 5.6 4.5 5.2 5.4 5.4 5.fl 5.9 5.8 2.1 2.8 3.4 4.1 4.4 4.8 5.2 2.7 3.4 4.1 4.8 5.3 5.9 6.6 1.<; 2.3 3.0 3.7 4.4 5.2 6.4 7.0 7.7 7.6 7.2 5.9 5.9 5.5 2.1 2.7 3.3 4.0 4.9 5.8 6.9 4.5 s.o 5.3 5.7 5.6 5.9 6.3 2.1 2.6 3.2 3.8 4.4 5.0 5.8 2.5 3.1 3.6 4.0 4.7 5.4 6.2 2.2 3.1 3.8 4.5 5.,5 6.3 7.1 2.8 3.1 3.4 3.7 4.1 4.5 5,0 . ~ -.. ---··-,.., .... t:. . ..:;s ·~ = .--:1~ sw~4~~~j ~.e:"~~;-~ 34,500 52, OOCt 7.0 8.2 7.1 7.2 6.5 6.3 6.1 7.6 5.6 6.2 6.3 7.2 6.4 8.1 6.7 7.5 6.0 7.1 6.6 7.9 7.2 8.3 5.7 5.4 5.1 5.0 5.2 5.7 5o6 7.2 8.3 9.2 a.o 9.1 7.5 8.5 8.2 10.3 13.3 11.4 2.4 2.7 5.0 5.5 7.4 8.6 8.3 9.8 6.9 7.0 5.6 s.a 9.0 10.7 3.5 3.7 .., 1 Q 1 ' .... ....... 6.2 7.0 6.2 7.0 8.o 9.9 8.1 10.2 5.3 5.4 9.5 12.1 6.8 7.0 7.2 8.2 7.7 9.3 8.4 8.9 5.6 6.4 :-.::~· ·=-... ~ c_ •• ,.• .. ·4~---~3 I • ~ .. ~ ~ ..., ~-.J-' ~-~~ ,....,.._.,......,""""'""""= .. -• '\ ' ' - ~~ ~~ .1: l. -. . _____ ..J___ ---·-., ---~· O-,.~=, _. ,. --~==~,,._:.:_ ~~~.,._,_:,:::'::::.=£~::-':.._...~~.:_«!: :;.~~.,._ ... t:~~~-. •w '«'i'~u::t.~~ ... -:;:-__ ·· ..... ·$~..;_ ~,;._.., __ ..,·: _.,_ _:~ --·-:..:.. .. ~-:._:,;.;,..., ... ·;-;-,.._,.;._t.~~.Lt . .U·~~~ _;~.:11 ~ ;a.c::-._:_--;:r~ ·L":' t 0 • -_: r:--:' l"-:: "*;! t ' l ,,": ~ .. ~ ...____. Table n (Continued) MEAN VELOCITIES ELEVATIONS t:.~~ " ...... ~. ~ '""" Mean Velocities (ft,ms1) for Indicated Discharge (cfs) Cross River Section Mi1&age 3,0_00 _?_!JIOQ 7,000 9,700 13, 4_Q_Q. 17, O_QQ 23,400 43.0 135.72 1.7 2.4 3.1 3.8 4.7 5.5 .6 .6 44.0 136.40 3.4 4.4 5.1 5.5 5.9 6.3 6.9 45.0 136.68 2.3 3.0 3.6 4.3 5.1 5.8 6.9 46.0 136 .~6 7.3 7.2 7.3 7.2 7.A 8.1 8.3 47.0 137.15 3.0 3.8 4,5 5.0 5.9 6.A 7.4 48.0 137.41 4.2 4e4 4,. 7 4.8 5.4 n.o n.1 49.0 138.23 3.1 3.9 4.7 5.5 4.9 5.4 6.0 50.0 138.48 2.0 2.5 3.1 3.7 4.0 4.fl 5.5 51.0 138.89 4.3 4.9 5 •. 3 6.1 6.5 6.5 6.8 52.0 139.44 2.2 2.7 2.6 2.4 2.7 3.2 3.5 53 .. 0 140.15 4.0 4 .. 2 ,,. 0 4.6 5.2 5.a 6.8 54.0 140.83 3.4 4.5 5.4 6.4 7.7 R.O 8.9 55.0 141.591 3.2 3.7 4.3 4.8 5.8 6.4 7.9 56.0 142.131 2.4 3.3 4.3 4.7 6.n 7.2 8.1 57.0 14:2.34 2.0 2.4 3.0 3.2 4.3 4.8 5.6 58.0 143.18 2.3 2.9 3.5 4.1 4.8 5.6 7.1 59.0 144.83 2.3 2.8 3.1 3.4 4.1 4.3 5.2 60.0 147.56 2.6 3.3 3.8 4.4 5~2 5.7 6.4 61.0 148.73 2.5 3.2 3.9 4.2 5.0 6.0 7.0 62.0 148.94 3.1 3.5 4.2 4.4 5.1 6o1 7.2 63.0 149.15 2.4 3.1 3.8 4.3 5.1 6.0 7.2 64.0. 149 .. 35 ~ 2.4 3.0 3.6 4.0 4.8 5.5 6.6 6!5.0 149.46 7.0 6.8 7.4 6.8 7.2 7.9 8.6 66.0 149.51 2.4 3.2 3.R 4.3 s.o 5.6 6.3 67.0 149.81 1.9 2.5 3.1 3.5 4.3 5.0 6.2 68.0 150.19 1.6 2.1 2.7 3.1 3.R 4.5 5.fi ~ 4~ A:,'l! ~-lt 34,500 52,000 7.9 9.4 8.3 9.6 8.8 lLl 9.6 10.4 9.1 10.6 7.2 8~1 7.3 8.7 7.2 9.6 7.6 10.8 4.3 5.7 8.5 9.7 9.3 10.6 9 .. 5 11.1 8.7 9.9 6.4 7.6 7.9 10.0 7.1 9.5 9.1 11.2 8 .s. 11.3 8.4 10.8 8.7 11.3 8.1 10.1 8.5 8.4 7.1 7.9 7.9 9.8 7.2 R.9 ' j·"• ;.,'llliil ·~"·· -J$ ''"....JjJ ...... .;:;~.-,;:;:;;;:;:li ) 1 _..,.,,..., ' I i l l IJ i(l . . f I J :I -,_..., t ' ; I I I I 'ue ' ' / ... .. "' 21; ·-- 11 \,. ., .. ~ "3p l \ "' ~ 'i ~ ~ u 12 ~ ~ ~ ~ ~ ~ ~ ~ ~ I ; l ... -. I ' ' I .; 2~ I ~ ~ !<\' " •• ..... ~(/) ~<" '-<:J ~ l' '" ~ u C) '-lJ V) V) V) \J ~ \..) f li _,, _..,..; Big Lake , J ' <i .. ··''-.~~ 16 ~ \}. '\ \..; ~ t' \(_, 1 f ~ j l 1\ l, ~ ! 1 r ~ l ~ l ~ j ~ i ~ I ~ I l I Q i I ~ i J ~ I ' \4.1 j I "' !\J ~ ~ 0 ~ ~ ~ ~ ""' <l V) ~ ...... (\.I ~ ' ' \l ~ <::; ' ~ \J ~ \J l(,j Vj \.) ~ < 4J ~ V) ~ C) ~ ~ V) =t V) '•l 't ~ \J ~ a \J •1!10 l"'~/ ~ ......... i '·t, \ i . : ~:2 . "7 ~ c-.. ' k. ~ ~ ~ ~ ~ ~ ~ \.. ~ ~ ~ ~ (' ~ I 0 \J "'J ~ ~ ~ I ~ ~ ~ ----·Jl,,$~ ''l l"q,,:;; ... :· .. •'!" 0 ,'' h 0 ~ ~ ~ ~ ~ ~ s ~ ~ ~ ~ 1' ~ ~ v ~ "'' ~ ~ V) '. ~ ;;::: V) . ~ ~ V) ' ~ h.: '\:) ~ '( ~ " \.J ' \J t r ' \.... ~ ~ d ~ ~.V) ;; ·< \J ......... C) ~ ~ ~ \.;: \.1 \.,j ~ \u \i! V) ~ V) V) \:::) ~ \J j > -----M·-~--- __ .,.,.._._, .. ,...._ __ _ I --··--····--------. . -I i LEGEND --- 1 f 3 I .tl --CROSS SECTION SUR • - -• VEVE ! -CROSS SECTIO :::> IN 1:181 NSURV .$Z ~ CROSS SEC EYED IN19B2 I II R''L TION FOR WH . . B @ i: ATIO.NS ARE PROVI~~H GAGE DISCHARGE z ·-\ • -"/ CROSS o•• D .. -.· A .<CTION NUMBC ~- 1 I . \ ' C ... R ! ' "'-ONTROL POINT ~ ; <Y S FOR HEC / \., I i I RECOMMENDED s -2 CALl BRA TION (,,,I ~ ~ I I TAFF GAGE ' I / 1 -2ooo "' I ,. . ~- ' < I . '· // u I \ . r-.. : .) j (!',/ o <til'" vW~? KO \ ! 'fv; . -... ·. ?' ~··· ~r---9.. . ' \. ' · <:. 88 ~7, . "( I ' ! " ( \ . •BG "3> d-\-7.<-;/ / 7 _; \ . ----~·-'-\ • .., -.--. <:.---"-..__ ---- ! "' . \("--...., ~ ' -.-~-·-----• ..... -.> __ ,. __ ~c' --····-"'-··---· ···-------_________ ... ! E>.:H !BIT 2~,.t,l I ! I \ \ i ,-.. ;~· ~ 11 '-87 ' r • I ~ I'• ol /""'· l ... ~ : . SUNSH ~ ~ . .../Z) l / . . ' ·'· ~ ~~~c:::7~)_ _ __.,.,. /\ I ~'lo ;r:;s. • ~~~~ ~ .A. J ·. I / \Y ~ ~~"'----~ 1.\ II/·-· ' " ~ " ~ , .. ' ~ .:::::--"'--""" ... L.... . .If/ . ., • L,",J I _...~~ ~-"" , I~ ·r; ll ~ ==-c:::.. =~ .:;.;....~~ , ~'-:-···--~" ·';~,.,.. . I . _./· ..I! C':1 ~ "' T;,.._/ r-\-. •· I ? C-J ·"-> I<" ~~ 6 _,.-:: ; ' -~/' ---~ ""' "" "" . "" ~ ... " ~ I I -·· • , f \Y li / J"/. . ~ «:::, ?'~ ""~,-' \ I I "" ~ -~ c ·=· fi /' \ I // r ~ •• <:---,. "'> "' o ' >f .. ' l i \{~ : ""-'>--yAJ +q3 / ' • ~ l ~ ; \rz•"tR 'Gl ' \ '· ' ~ \ \ '(f)' I _.;·1. \ c:2 ~ ..... 1 . \, ./ I ~--,-\ ._;..;} l ' jl -..., , 1, /,.---, «..,~ .. 1 ·3 1 1'71' ' . • ': tt .. ~ d#Jt,rH" l~~~ / ~~·4 '_.qs ~ \ ~ / • ,. (, '· ' '<: .0~ . \:.!1 ) I . . I ""="' ~/ =-7 ""' IL -· ,../' ~ q4 \ . I \....----y . .': . . «;v:·/ _ _,_..--~ ___.. ..... ~ .... ,., ....... -~·' HARZA·EBASCO SUSlTNA JOINT VENTURE OCTOBER, 1983 ---·-·~·-----··--_,..:;__ _____________ , _,~,,_.,..____.""'"-''~ ···""~--......---~-·,~·-~~~~-~~''t""7'~--'-"""'"--~·-~---·---"'~·~-~ .... -.---....-----~ ... ~: c lo..i.JII¥ ...... :Mia SUSITNA HYDROEL.ECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS ----"'-'"'""'"_"" __________________ _ --·--··---"·----· ···---··------···-·-·"·-··------· ------··;~-;;~-;;-;~;, l i -·.I ........... I ~! -I \ !I t. d '\, ' -~·, '\ I ~I • I 1 >r p';~ ' "" / &" \ " \ '~L-----'\ q8~ i \ \ ""' I €) ~~-~ \ l Sf/S/TNA !J -~ l ..... .) \ ' \ ~--·,! .lr" --1 f l . /.f ~ u. ~ ! . / ~ I L- i 1 ! • <~ ! 1 t " ) "'-... _tt:2'\ ....... ~ ~ ·r @ J . r-7 ~--,.o \ L.5 ,.....-- "11J.{ \~ " ~ \ ..::.::, ~ Vt'i ~-9 ~-------~-:;;> < 1<~:~:-rNA R. v~!\ "- l<J ............... ' \ \. \ ~ LEGEND f , ~ ,- • CROSS SECTION SURVEYED IN 1981 . \ ~ ~ r""J V -~:::f' ' 0 . / / {7?~1>;(-------~=--~-~, ~:::::::::;~:~:::;A~::ISCHARGE !~ @r_\.,t-1,/r ~-/4 . J:.:.J RELATIONS ARE PROVIDED j ,. ~ )_, r ~ @ CROSSSECTJONNUMBER . \ /.-'"" ~· \ ./.1~\1, \.;!;> A. CONTROL POINTS FOR HEC-2 CALIBRATION I ~·" (8} RECOMMENDED STAFF GAGE LOCATIONS L.---' SCALE ~ , 1 = /ooo \ ·---l~ q;~ )~-----.. \ . -------:---'"-·- ~~~ .:. I v"' (. "'-...... /-/· ...... I I c} -~ I I 0 ...... _.' (\. \. ~~ ~ ( I /-.-· __..._.., ~ -. / --... _r I -\ ~' :& 1-~/ \ +1: ® ~ ~ :D~'? ./ /]-J. oh ! j ~ I y J/{/ \ z.__/ ~ ~ I I I<JVE;< _./,-<:...'--'e . ]J-:_~+ I(§ ~ ~/~) ·B ft ·--"-'1 ~ Je ·-r~ _/1--j> ~--~ ~?"'·~¥ --....__ ..... " ;::::::._././;, 0 v :S SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS . I ! ! _____ , . : I HARZA-EBASCO SUSITNA JOINT VENTURE OCTOBER, 1983 -------------------- .,. ____ ,..._,. ____ >~~,_.--.......,..,.-dr..t,...,_ _ _,_,~.--... ~~v---"-_..__.:.,_, --,-..-...-....>::"~.~~~~.....,.~ -, ' ., . • ... ...... • .. '\ H <II.. • ll ~ d. ,! ·.... ~-· ~ " :..~ ...... -:~ .. ~dt?,.; ~.,'If~ ~~-~<--. ~ .. -"(~~': lj I I ! 4~ ! -~· ....,... __ ..,.,.,. ____ ,..._ ... ,,._ ...... _,.._ ___ _......._ __ .,...,._._ ________________ _ ---------....... -......... ____ .. ______ _ ~ .· I .-----;,..,.. ~ l ·-- I. i \ "''\·'' · · LEGEND / .t:::;-, /--· t , ® . / I' --·---CROSSSECTIONSURVEYEOIN19B2 ./ .;7 7 .. LEG i -~ROSS SECTIOI\1 SURVEYED IN 1931 _./ A _\ . I . ~ ~ w .,. •. "' ~ CROSS SECTIO.N FOR WHICH GAGE DISCHARGE ~ ./'"/ // I f RE!..ATH>NS ARE PROVIDED X".-. 0 r, / . . 1 0 CROSS SECTION NUM"E" @ y -... . t A CONTBI'JtPOINTS FCH HEC-:l:"CALI8RATION ·v ~· I ! ® RECOMMI:NDEI) STAfF GAGE LOCATIONS .P / ' ! ~ / tiA r-·'-~ ;; 1· } SCALE I ::: /00{} ,0~ .y.-fl ; ~ . ll ~s" L· '2.rv'' ( l l .: , .oa f I . 0 .l ~ /'~2.,-J 0'' ! ·-· ..... ,. l / . . ,...... . ..; ! ')(' / J''/ ,o':J i ! /~ ! \~ /'// /./ ! ____ ... _ . . -· -....._ I I .....__.., i · 1~ q~ sv.,/>-'-.. / <>'VJ ~ ·\~ __)§(~~"'} ~ I/ \ "' ''"' ? I , /~ i SLOli(,H ~ _jl/i ~:JD/ J ~- ~~~" r -;- ! \,I ' i ,, r ~~~ ~ \ -S VSir"A'A 10 8 ~_.J../!:, ___. ->( ...---- ' ~~---' ~ r. '\' '·' \. '\ SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS ;t! j . • HARZA-EBASCO SUSIT~,~~..:_~~,NTUR;_?.:To~_:_R_:, ::~3--·-:•·--·· "'"""--···· .n,••· ..... _"_._,_ --·----· J •• r s-~,, 'ftf'S - l ' I ! i i I I l t l l t l I I i \ ,-·, I •; .1.1. '· j . < -. . I I ~ I ·I ; • ~ • 1 11 i I j I I ~ ~} ! i ; ' I i i l ~ . i l : ! j t l J I ~ i ! i . . . j 1 ~ ~ 1 t ! j '\ l ! ·--------------.--___ .,_. .... -.,~ ... ·-•••u_.., _____ , ___ ..,."~' ., .... __._""'"'···-----•*-·"'"'"'-~ ,.,,... __ .,_..._ ....... -.-.--. . .-.. .,.~.-..,,-. ...-• ..--... ....... - <1' w _..,., .. ,..,.....,..,- \ ......... "/------------~oJSI(JJf'o X~~+,;· . 0/5?-;::(g 0 !. _//_,/ ~-r;J. 1 /~' I ~ ' . J \.Ql. . ·. r / . £ l_/_ .. - 1 I r~ ~~/;;/;·--· lEGEND [,,,;11 s .. ® CRO~S SECTION SURVEYED IN 1981 CROS!) SECTJON SURVEYED IN 1982 CROSS SECTION FOR WHICH GAGE DISCHARGE RELATior.;s ARF-PROVIDED CROSS SECTION NUMBER CONTROL POINTS FOR HEC-'2 CALIBRATION RECOMMENDED STAFF GAGE LOCATIONS ~ " .QCALE 1 =: {ooo IL.-..-, :/• -·· ~-... -·· ~'-..-r---- I I HARZA-ESASCO _:'USITNA JOINT VENTURO:..~."ER. ':_83 ___________ _ ·····¥-~--,-:~:---.. ---. --·---·-~--~~----;,:-·--~~~-:------:;:-~ .. ~.'f~~ z _,_ / (2 ,..;£ /2.. E'Xf/18/T -~-..,~ ' I '"'~---' +11-4 -~~~ ,./', ----__./-~~· ~ ~~:::.:- ~ SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS 2-~--l l I l I I I i l ! I ! I I ! I 'j I I; ' i ., ,I 'i Ill ,,: I j -I t Flr l ! l l} I I ---.--~· ,. ... ~ . ·-------4" ......... ----~-_.. .. __ .. __ ,.. ··---·••!.• ..... ___ ._ __ , ....... -~-" .. ,.. ___ ............. -----~~'O.J.olo. > ..... ,,. ... Kt•- j) ;;:~:~ .il ,.------ . ...,__ ---:. · / .... Jzo "" ---.... ,-\) 4----1~~--· ,..,,,/~r? ~ .,,.. .... _ ..,.---- ' ~--~ \ // -·· ..,....-/~ ,..-~-.~.__...-r ~; -r/11 ' I ~~.,. ... ; 1.0 ""-~ ~- • 1 ~,., \ _]3! sUsJrtJ/' '-----/' ! I /'" til8 1; . ~ ---~/ ..•. ~§'"' .~ ExH/Btr 2-£ .... _. .. ---· ... '·---·-~ "l I ~ I ! ! ! ! ! I i I i l l ! I '--·-\. ____ //----I \ I ~ I~ I I lEGENr> ) 1---~ l @ . A r--c::)~ i~ CROSS SECTION SURVEYED IN 1981 CROSS SECTION SURVEYED IN 1982 CROSS SECTIOi.: FOR WHICH GAGE DISCHARGE RELATmNS ARE PROVIDED CROSS SECiiON NUMBER CONTROLPOINTS FOR HEC-2CALIBRATION RECOMMENDED STAFF GAGE LOCATIONS ~ I SCALE L,..Joco I ® I I ""·~~~?.~~.~TNA JOINT VENTURE OCT~.=E~R,!-.1~9~8~3------------------------ -~··---~·-·----·---.,.--~-·~-~-----·-~~.--,---~ -"···-·--·-:-·-;~--~.,...,.·•--~. '--::-·--:----~~._lfliJJR111JIZ- p ' • ...... ............ -,-.,.!!!!1!!! ' ··~ Oc..re: \\ S~o(/1!;#,;::~ -...__ SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSSSECTIONS, STAFF GAGES AND SLOUGHS I I l I l i I l j 1 i • I I i ·I ·----... ~.,.._. __ . ,,..., ... ---~-----__ ....__ -"'·---··-·-·~-... ----,..-~-----_.. ___ ,..,,...._..""""',. ___ .... _.,_._ ,.._,..,, ...... I I I I : I. ~ I f ! i ~ 1 · .. ·-~ ' f I -' l • l i I i I J i I l I l EXJ/i8Jr 2-,C I \ _ ... _._,.,. ____ j::.-""-~7 \ \ . ~ \ 0 --/'~ -t!ZS"___ SO'S'r"-'A "------h•'· . /:;;;-, 'f i ':"~ -~ . .12.6. ®\ ~/ ~·)' ' / {}-· ~ ' ~~4 /~' -<---. ~· \ . ~'\ ·\ I -___.----; I '!.. ----....... ·~ ' / / \.. ... •,..{ \ =-; (_ / ~-' 1/(j........_-----· v \ \ _./ /'j \ //' l !f \ · ct:: .-/ vk·---_/ /"'/ 1 ~~.. __ .... <==~-~ l . \ . i'V. J i I ~ LEGEND -------------~0~ e ./1& ® ) \"U(.. +tz-7 f]>t,. ~-r--!::::.. c:j x~. 0 s CROSS SECTION SURVEYED IN 198i CROSS SECTION SURVEYED IN 1982 CROSS SECTION FOR WHICH GAGE DISCHARGE RELATIONS ARE PROVIDED CROSS SECTION NUMBER CONTROL POINTS FOR HEC-2 CALIBRATJON RECOMMENDED STAFF GAGE LOCATIONS ~ , SCALE ~ ..z::/000 ~\ I \C\ // --0:;/ ~ / SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS STAFF GAGES AND SLOUGHS j HARZA·E~~.~O SU~~~~!_V_E~!.~~:~~!?~.E~:.:~=---·-"-, • -~-----··----· ---------..--___ ,.,..,-,o;-...a•"'~--"-__ _..""',._ 11#~~"".:-... "t.>t/_..,. _.,.,.,. • • •• •'W''"'"''"~'" -·-•~ ,. .. .,_ .. ~-·--""-'--'·"·----~.,.....,._."""':"··-r,~ ................. ___,.. ....... ,--~---···"<-'~--'-----·-.---~~~ .. ,~~--·~~---·~-~;;:~~~~~.Y"t,W.~~ ~ t I f t r;. ---------~--·-··~ "'*'U·•••••"-••• . i. ' ! t :·, l l ' I j I I I 'I I t I l I I f l ~ j .. ~ J l '· i I ~ i ) (' ,, • I ' l --.i ' ~ I jJ 1 '' i J I t '' j ( I f ·, l I ~., ..... .,. ~~""~·.-.. -... " ...... :><•• ................ .-• .,._, .. _ .... ,.~..-~._ .. ·-··--·-~-,.---·-·-............... _ .. ___ ,.._._,....,, ___ ..,._.....,._ ~ ~""""··--~---·-.. --.•• -· ~,. ·-... -....... ~·-.--... --.- I ~~'), "-..-------'~//~-..__../----(.__ +133-~ ; C'\ \~~ ~· __ r<1Ver< t: LEGEND ---' -- ·---~ (0 .... ® .·~~· '"\ --~\fq •· ·' _c.....// ·..) ~a. ~ '.:::::;:::.::/ sJ.OrWI '7A ~SL•'-"1-!IO f.ROSS SECTION. SURVEYED IN 1981 CROSS SECTION SURVEYED IN 1982 CROSS SECTION FOR WHICH GAGE lliSCHARGE RELATIONS ARE PROVIDED CROSS SECTION NUMBER CONTROL POii\ITS FOR HEC-Z CALIBRATION RECOMMENDED STAFF GAGE LOCATIONS ,., / SCALE I: /Ot>D R/Vc:-R ,!j!; ·-~ / "" ~ +-'3>-----..J(f':./ EX'ii!Bir 2-Ci SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS I l t l I t 1 f 1 J HA~ZA-'CBASCO SUSJTNA JOINT VENTURE OCTOBER, 1983 .,.._.....,.._.,_._ ··-...... !,J;.-.,i'O'W------~-------------·-__.... ___ _ i ..... ""' -·•c -n .,.,....,_.tt••' ·-~~>·· ""'".,._.,.,_ .... "'-.'"•"-.. ·"-'--......_f~1:-t-..,.....,.-t-,._11'-'"'--"'""""'..,_ -· .... ---~,.. ___________ .,; ~-.... ~--~· ... ,...._~·~~-"'" ............ ,. _.., ........ --~.-.... -~--............. "'"'""..---....---_"'1. ..... _"" .. '""" __ .... ~._,..--.. ~...,...·#·-........... ~.-...... _ .... _ ·---.... --------··-· .. ~-_, .. _ ... ___ ... __ ,. • ....------... -~ .... ' .. __ _.,..........,..,.~:-·~-...... ....___ ··-···· ..... --~·-·--------- i ! . 1 ., I j •l •I 'tt ·. ~ I . I I t I I 1 I J i I J t ; f i f J f ., i :·! \ LEGEND --- ----·~ C0 A.. ® :;:..-· ,l.r-<d<:. ~~<>'..y..r ,..> . -_.e --~~ =-~ ·' I • -StJS'(,tA +14D ~-L~~ ~ -......_ ----t-- .Su..r...-_:.-. -v +14.3 CROSS SECTION SURVEYED IN 1981 CROSS sec·noN SURVEYED IN 1982 --"9 CROSS SECTION FOR WHICH GAGE DISCHARGE RELATIONS ARE PROVIDED CROSS SECTION NUMBER CONTROL POINTS FOR HEC-2 CALIBRATION RECOMMENDED STAFF GAGE LOCATIONS _, I """" SCALE I ;/Do" / ·~ HARZA·EBASCO SUSJTNA JOINT VENTURE OCTOBER. 1983 .... .w· ....... ,._ ... <= ____ .. ___ • __ ..,,. .. _,.,.._. "'""''" ..... ,._ • .,-.---·~·-...... ~ ... ~ .. -...... 1-\10>'-----.. -...... ----..... ---~------""· _,_.._ .. _., .. _, ~---<>-·'~ . ....--.----·------··--·-;::.-......... ·"'~--'1~1'----. _....,. .. ....,-~......-..·-· €'X#I(J.IT \ -----------\ ~\ ) .... !""........ ' ~__../ /-----=------1----l . ~'-~'-:\ -· \ J . B + J-4S I ·~· \ SUSITNA HYDROELECTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS z-Hl { I l I I t I (' '"' ~~ l· . t::l --------< I ··-·~·· I ------.. ---· .. --.-----··-·----.... --'"'ll.-...-, ... _____ _ _______ , ________ _ I al I I ~I {• I l l . I ( _l . J J I j I --------~ ' { 1__.--·A _st1tJ ·~ LEGEND -------0 e A. ® CROSS SECTION SURVEYED IN 1981 CROSS SECTION SURVEYED IN 1982 CROSS SECTION FOR WHICH GAGE DISCHARGE RELATIONS ARE PROVIDED CROSS SECTION NUMBER CONTROL POINTS FOR HEC-2 CALIBRATION RECOMMENDED STAFF GAGE LOCATIONS !sCALE I' ~--/:: 1•,.:- I HARZA·EBASCO SUSITNA JOINT VENTURE OCTOBER, 1983 ----------------~------~-------------------------------- 0 .... ; ~ _ ............ ~ ... ,., ............ .,,_ ... __ _ J EX.HJ81T z.r 1 ~ SU')ITNA HYDROEL~::CTRIC PROJECT LOCATIONS OF RIVER CROSS SECTIONS, STAFF GAGES AND SLOUGHS I' li<IIO'IIlllT l'AI·Jit '0 Iii> '1;4~ HnJI~IlHON$ ,;tlltl;;.fl bOTH V.I>.~J I~Gl hlliDIVtifu}j'ij'" , ~~_,J au•-• ---P IINUD IN U li.A. ON Cl,tAIIPHINl f((;>lNICA• l'l>l'tll NO 101, r:·l .. n-; ·hJ.· ...... ""'}"\ "'' • ' • t .... :-<:. 'l • I~ .l. ; ' t , '\S 1\._• j •• ~ ~\--.~!,.:~ ~ ~" ~ ~ .. , ·~: ).,_ •OtJ/ t,.;' ~ .. ~"!.~:\--· f) I ~. ~: . ~. . : .... . :G . ~ ! .... "' ~.:: '\\ . ; ' --~_,._.. . .:s: • I . ~L .. ~ • , . ! . . I . . . ~ i . '. -~ ~ ; ' .. ~ ~ ~ ; : 'l· : : ·:o:~ ~i: _.. • • t I .... ~. t,.. •• "1"\''-. ' ~"-1 .. ... ·(\' ' . "-!' ••. . \ ........ , ---,.~· • ' t" ... ... '!:; .. 1> .,.... •• , ..... · ... --..,,.. .... • t .. t "'. t t t ~ • • ~ . •t• • • ~~ . ' t , I ~ ~ I t I t • ! • '{\•·+-··~·· • ! .. f t-4 ~ !~f .. ~ , • .. • ,. ... • .. ~ I' t " .,.. • .. f P>i -t· •· · · · · · · l · · · · ~ L t , : • -t.J--.....,.__,. .... _ + ... ·•"'... ..., ._....,._ __ ............... +-+--'*~ • • • -t-· ••·• • ' + • • • t • • ' t • • • .; j >-• I • H ..... .,.._ ' .. + ....,_ +. .... • • t I . ., ... ,.. + t • ~ .. t ~ t ••-+-·•~ ............. 1 ..... + .............. .. ...... *' .... _.... • •-+.. t' • • • .... ; .... ,. .. t ••• t , .. J . ....... . t i .. . ~ .,J,_ •• j.U).,.. . . ,, . ' . l . t ' • [*'' -t t ... ~"' u . #o +..... • .. .. .. I .. .. ,.~.. _..,. ....... ~ .. .. .,. ~ .. """ ... ·~ + ~ 1< I! •• t '*. .. ,. t ... .. 'f' ·Wl ..... + ·+ t • t .. .. • .f .. t-t -:>.J ~--+~-,.-,,·~* ·-•!-++»+~ ····~ ........... ''l!''f ... y,.-... t••• .•• tftl t·~ ~,t .. t•t" ·~: 'It' f r ~ • t • I f • t + t .. 1 t ~ .. , 1' ~-·1 ' . : ; II I I ; I '· ~ I I ~ ; i +-ti·•· ~~-t-.. !"t'' ¥~i t~t ~ t t + t • t 1 t • • . . ... ~ t ...... ·t-""1''"" ...... ., t -t • I r • t t f ~+ + ~ J 1-t • t t .. ..., .. 1' • ~ • • • "' I ,.. ~ -f. -• I .,. ~ + • f 1'''t -t· t -.-.."';>i.::~:.::-. ::·.;_;-: t:. ; ... :_. · . .:.~ :r :; ! 1: ·1g t·t_ ·+-~ 't'"' ....... ~.... "" f .-t•i ~+ t 1·-*· '1-t t ,i ;.,_, .• + -i-+· t-·~'*-sr --~ .. 1-* t .. ' .. "' + .~ .. .,. ...... r-... r~-. t t t ! -~": -+-· ~ ..,_ . ...__ ..........,_·+·HH--l- +4 t;:; , ... •+ t4·n· · . ·t; • .. ... .. .......... • ............. .;-t 1 ..... i l t t 11 .. .,.. t-·:"J -· t ;·•-...... : ' l . ,. : ·•. "'~ + """' + ... +~ -l l-' t ~ • "'" t f +~~·-~· .. ~ -·--t " t ;. i"" ·t·"~· •t1f·t 1 f I j .... -~ .. +ll-........ 1"· ... t ... :;_-~~4ij_' ·-; ~-t~·~ l!l: .. t*" ... t 1 t t I 1 r+·~~ ·t t rt t·t t. t.;.l)i ·-i·•·t• ·t·i It +--~,:~-·-t·tr. 11~ ~ i ~ l I ~ t-f; CUAI,II.v Q."ID1 ., ! II ~ 1 I I It II :. :' :\'.I'!! I I' i\lll' i;' I.'! ll !+-H~-1 ........ ~.-.-.--, , 1-t-t--r-r-r--t'\. I., I It I , ,.,.; • 4 ~ t ~ t t f' ~ -t-··t· t .: f t • f. + -• t~-+ ... + t , j ~ .. t t · t-. to • or t .. ); • l t • 1 t .. ~ t t'--t ' . 't . . ~ . I . . . ' .... t J ) t. l t 1' ; ~ ..,.. .... t ... 7 1' +· t . t 04 J •• t ; I 1 i It' I \I! t ~ . ~ ~ "!" t· !" t ... ~ ··-~-rmr· ·~-" -~·,. · ; , • I I • i : il ... ;-• .. .t ~ t i • ····r····l ; .. .. • • + ~-,._ ;"'~~ .-' .. --·--.. -+..-....-+-.,....._ -+--+ ·-+· ,.... .. ~ ... . .. . ~ .. . .. ~. ... .. .. + .. • .. .. 1 .. ' • t +. t J -t ,._ + ; I I • ! ~ ' J ... I · t ~ .. 't j t' 'J l ~ ~ i • i lj·• p.l I ·i i t t i t · i· 1 ! ·t· H -· --·t--. ... ...... • .. +-i ! +· 1 , i I f Ill! ·rr~ ~ -t, [L I · ~t~-t t ~ ,l : ··! ~ i· I J t·· i .. , ·• ~ " I . t t t t -~ ' ~~!!: .:·· --:_o.~I ··'f,;Jg:,~ .. ,, ,, . . ~­.. 0 -'Jr ·'•' .r 0 ' r··, ... HOJ5hh-u \All .k Ot.' ....... M ••J.Ot,~-rto~t-it W,:~ lit-., ..... MOOt 1111 .. ""' QU ., l '·' ~~ ' I ' '\~,) '· ., - -----MM4 -. 0 -r-··~·---- ' · ..,NOJS$An.t u~f X OU ,....., •• t\ H:.tO-. ~ .... ,H ttlJ ~ .MQQI I)N " . ' ! . "··~ ·, &.'. ·/;:~ • ~;r 6 - -- .. "' ~-.1.· ~ .. ' .'~' ' 1-l' --~:·j ~-l,'J·l:l: _--_-----···· ---:r ·-_-:~-.-t.l~·-··1!::.· :j·l'-·'LIJ -~·lj-t·-Hl-1--,..1t-!---r-!'··!~·r·1-·--···· '•· l I .J .. , t· . --i--l= r-t I i 1-·i·_j:_t--H -~ -:T:t---.... ~ -r~-·-~ -~-. -:~·i·:. j: i : -~ .. :. -, ... ·. : :·:. -: -I . i ·i·:. Tl ·1 ~~~-!-~+ :.q :r--.. ·f-1l ~~.:r::t·: : :. ~~,l~ ~11 ~ . ,l ' " ---: --I ·. I . ro~ ' ': ~-.I:: :. ': . : . ~ .r, I ~~>~!TlT :v I I ' I' -. I I I ~ ., . ,. I I I 1--I )'J ., • I ~ II 'i\ \ [\ -::. . ~ .. l I I ~ I r l: t -:· :· r : I II-rL r-i .. !:: ; : .'11 · ~~t -"'~ \·\, · -----· -~ -: ·: ~~-=: : · -~ :·:~:-I-: 'f~ ; otti \-i:HrtiTF tt ' \, . t ~, ~\, -. ~ ~; : ~: :. ; : : r ~ I ~ -: -l : ,-, H '\r 1 ~<~:~ >\~f\~, · ---; :-+-r+1,fr , 1 ~ ~ : :: t 1:, . L[ ~!(l,:~1f.1 \ 1111 1 I -~ = t\ 1\ i\[\ ---1 1 -&l tt. -----I-i·1 t -1 .!: -H~+·~r.:.,· r-.l!,l! 1:11.--i\~: jr\"'_r~N 1\".1· .. -~~:~:~~--:>+ ffi:!l -~ ~-~ :-~,:.Jll_ :l_l·tr: .. ·:~-~--!·~-~-~5-f:.!.j~~ I; ol ···' 1,1 1-i\ f\·---.. ----I •. "1-1-r. I -· !,;-~---It T -. 'I . --. -f 1\1\--~1 i\" "" .. -.. . . -.. - -.. -.. = : -.l . -. .. g ;~ = ~ i!j .. : ~IT-J I ·j· i\1 I' -~!\ -· ..... . ·V , .. ~-.... 1\ f\ 1\ 1\ .... .. . • .•. ···t p._.. •••. --·. I.-I .:: ... N '\ ":::-_ ~'~-· ~-=--~-.. .: =·~----~·!· ··. r~lti .. _i_l: :~.: -1--· ·--~-::: ... "'[\r-----1:~1\ _1\' --=~~~-:-·.--.-... --: .. --:-_ :.1,.:·:-11'' -. • -[\ 1\ -1\· -• . • --.• • • • • • -. --" 1\ . --I~ .. • -1\ . -- -• • -• .. •• • I • ··· .. 1\ --I'· ·• • - -•. , • . - . .. , •. . .. i\ ·[\··-1-' •• ---... .... -• ... . ·l---n· -- . . . -1\ . _P.. r;_ :· -f\ . . . .. II --. ~ . -.. .: --.. -.. - . .. . --.. -: :I . :_ : ... - -t",lr • 1:! -.. : - . ~-~ • • . ~~ D • . "I\ IJ .. -• -. • -.. . • • • . • • -• -• • - . .. • • .. • • --~-... -..... ·---~"~~~~~-n-·:·~;-_·> ~---... ~:~. ---~-------~-~------~--.:-~ --·ffi: .. -. . . ---=~ :" ~ . :: ~ X -. : . ~: -l. -:: : . .. ... :-. ~ .. ---. . ·_ --:· -. : .... -~--- --· · · · • !'l 1\ ·i\1·· .. H -· • · - -• · ·• - --· · -• -· , -f-~-• • H. -+-1-l-+-1--1-_H-+-1-4-l--~. -1-t-1-!-1-1 • -.. i\. 1\ . -.. • -• • .. • .. -. -• • l • -. . .. --.I'\,~ •• . ·----·i\ r--,·-~----j\· .. ---.. -.... ·-·~; . . ,TI.-··: ..... ·r·--~·-}-r -·r·.. -1\i'\ :"=:~-=--\ . --~ ::· -----------:J: .. _···_--c-·· ==~r = I. j1 • ··: .·:. -~r-=·-\'"-~ --!:i\:-_ _::__-----~---:~ .:~;--.:: 1-'f·-~·:·1 • . .. ... . -··-__ " _ _ __ _ .. ++-~---r-I..L±----1 -~. ·I I I - -I I . • . ·--\--i ·-. -. --.... -. --. - . , Tf" + 1 ~r-r-j t; TT! li ,. ·--~ --: :: =~--=----1 --\:-'::, =~~t .. l\",--·:-~:. .... : . -·1: :J:-J:r· -_ . -~:Q:!-~ -~~i-.r· :., . . :::_::-_-_-----... .,-d--f'·:.~--.--1-\--_::.:··-.: l:...._-~-·tJ:..· ~~~- . -.. _-~-r ---~ :-·--: ---= -: :: : -... -= 1.:\ ~ 1\ -~ ~ -1\ -= .. --~ -----= : -f L_ : -----~ • -?J~ • . . . --•· .. . .. . . -· - -. -~ . . . i\ - -.. ------ . . -· . . -. . . ---r~ -• • • - -• -• -.. .. I • -i\ -• -..... -.. . ----. .. .. I -. . -· -. - ~---~--£.:J ~ll!l~·ti1·•' j1 -~:\11,, I\~. ·1.'\\'· .. !--1 1~t+.t:t··+·-+ ;.·:;: Jl t :~t.l i~r~~.P-1.:!: 11:L :::~~!:: ~ I 1 I I . . I I l j !\, I \1 f '1 ··~ . j 1 t . t I i • I i-! I 1 ~ ! : ~~~ ~ ~ ~ 1 ! I • ! j ! 1 I ;· ~ 1 p· ' ' ' • ·-~ 1.-iJ!T\~ "liKf -~,it \ ·i.l 'i'.l L . t tiii i ·.l iii.i ~-~~iHtii 'II tm.t'if..ij;.~i 11 1 1 . 1 !\ · 1 ~ . \ 1\ I t I + f l -, i 1 ' 1 t 1 l i u 11 e-'' 1' 1 ~ t • 1 : i -1 . r r ++I 1 ,,·jj'·l' !Jjl-1 \ tLI . ;.\I ,lr\ro,.· ····ttm·. +.t·tT-tl.ll·-Jl .. llH riJlt t.t·r:i1' ,§ff5i:.-~.: t·i!: -l1.tt.·.:tr:··tL:. . 1 1 l -· ll I " 1\i I ! I 1 "· · . . ~ r • d.L ·-· · t I !t + l P j U)'"ios;:.t-~ 1-t • • 1 ~ I · 1 t·t ~ --H • t I : l ! I i j I r !. t ! l l ; :\ ; l 1\ j ·, ! · 4 t ~ 1 · h + ·· l 1 1 ; t-f ! t · t ~· 1 l ! t.);.:=} :'-\ H ; r i • 1 -• . · !· ~li +-r rt .... _,...,. -·-H-+-• "!"1" :·r--...J...+-.... ~+-" , ~-. . "' -. . c..~ . • • • . • • I ' . ! ·+ . . • • • • • ' •. • • l I 1'\. . ' ·! • ' ~-'1"t' -j---t • ..• I ••• ·•. '. . .j • j.. I· .... ·.::--. -{'-• ..• -~ . • • . • . FF -~ ' I ! • • • j' . l· : ! l ~ I ; ' t • i l ; t ._, 'I > t ii' -t t t• ' t • ' j. • t l ; + . -i ·l' ' . 1-, .. ·-·l' ; ~ -F ~· + • ; I ' • • I ! t· 1-+' !•i: !l f I i~·~,jl Ill --~N\t! ! ... -·J·tj·l tth-··t. -··j·1·1 ~.~-t~d-:-t tlti ·tHJ··1·+· J. !-. , 1 • , . 1 t .• 1 , 1 - . ----J t-·-·-t·· --• ~ ' • 1 1 •-· · j t 1 i 1:51. ..... •. + ~ + -•--1 , 1 '·t· t ·r --t-t-+>-H-++-l • " \ 1 , ' ' , I · ~ '' ~--_.)_ ' ' ! J 1, • r·· .... ,...,,..) r"'--'r ' ' \ " ' ·~ ' '5NOUiiA.IO ool X O'l 'KJ,VM IHOil H~NI Ill" UIU!-11110 01 ~V.1 ON .- l J. _..__ ----. . . '-. ' ~-.-.--:. ... .-. . . . . -- ,1 .. j 1 ... !I,, lj ~ . I t • I . I ! l • ; : • ! i ,~~~ ·~~­-j ....... t .•.•.• J 1 "' l t ' " 11 ! • '4'l Tf·t ~,-.. ' ~ 1 • : • ""lf t t ~ -- -• -• r~.;-·~oi=::o ~ i.t.,•l -#If h >1 t'ld l,W' ••fiJI ":~,U t!:!.M1'!~t1V :1 ~ J Uu 'f b i1 f.~.~-'!.J.U,UfJ --IU - f . F~~f:6 ;~{.~~~-~~;~ . ' ,. ' ' ',. '~~--. ' ,.·~ ;'.....; .j) r-~--l r--~·----\ r~·-··<-·--! ···--,··--·~·; ~--r"~"··-··· ,.......,".,,.., .. oftHAlU Wl) OGI 11.\'f'M.'HJ.OIIt tf,.fNf -.1a SNUtllirl\iD o, '-.,.., ~N ., ' -I I ~I 2 .J < !I l-.. ~~ ~ ' "' ' ... u ' :z ~~-~ ' j !] ~. 3 .. :z 11 ~ I !( J u ~ ' • .. ... I u i .. .. ii ____ , __________ -,---~----- - --- -r::~-~~;rmo·-:·)3) ~101 OIIIU"'I'<I ,Y•IIUI;)H Jlllii4U~l1::JIIO 'Y"ti'O Ill Ol!NIIIol I ~NOitli\IO 001 ~ 0" S~VM H~OR II INI lllolliNOillh\10 01 ~',) PH o;.o UdY• •I<IM~UVl,:> r --~· ( · "·-· ~ ! ~ ~ 81101~11\IQ 001 i( 01>1"" 'JJ,YM "•"•ti::IHI .,._ ~ "OIGI/\ () .... ·: 'I --~t 7' SNOISI/110 001 ~ OGI U.l(NI HlOQ H:lNl loll"' ~NOISIMO 01 "':1 ON 0:;) lUoil(ol ~NIII•Uit<l,ll I I I I I I I I I I 352 ~ w 350 > w ~ 34-B < w (/) z < ~ 34io w > 0 m < l]f ,, 1-~o."il~ w UJ LL .. z 0 t= 31.!2 < > w _. w 338 33{o 0 ~~="'=•=~~-=="""~''"~'~""'"~=~_,." .. ~-<<l""'"'·"-'-''"'"..,.,,.--~~.,-li..,.,,..~-'·,._,.,.,,.___.,., •. ~-.~-N.:o.--~J.III)l'""',..._;r"".~"­ . l J l • l • • • i 1 1 .l' ···.·······t· ·:-·· l' ... • • • : l • • . . ' . ., • -l . --· .. . 1 " ···~·-·· ...... i· .. ·, ... .:. .. " . -----~---·-·t--·---·-~----i-·---.. -·-.. ---·-;------. -r·--:·--·- ·••· ••i .• ' • "'1 .. ···-·····~· .. ·-.. . ·-: ··j···; ...... ··,.t··---·~---· ..... . ' l . l . I ...... -·-- j . " . -.·--_ ·- 1 . .. • . -. -·-: 1 : . . : .. ~-. -~ ~ . ~ . : ,. : . : . :. ~ . ~ ~. ~ . . . . . _. ~ . .. : ] : : : : -~· . ~ . . -. -·-. . . . -~ --. ·.· -. . . -. . -. . . I . . : . t ~ -.. ~ -j ... ~ : . : : : : ~.I . : . . . ! . ·:.: .: . 1 :. ~ ... : . : i .. :. . ~ . . . . . .. I • • 1 .... : . . . . 1 ....... ~ !-~-·: ........ ~ ..... , .... -..~ .. . . --· -----.:.. -. ·--·t··-~·---+---·--·+ -·--: -·---··1---·~··---·--· ...,.,._ • • - ' " .. -• ~ • • .. I ,.,.. • -" •. J '·· -i .•... l.. • •· • 1, .. ·······!··· ..... I···. j'··· :·· ' . . .. •••·· •• ••••• ., •·•-•·-~• -· ·-•·• • I . : . . : . . ~ < . ~ ~ ; ~ : ~ : . ~ i : : ·k' : .-.. : ; : : ~i .. ; : . : : +---+·------~--·-... ---1--"'--'-.. ---.......--.... .,._-~-----· ----""~ ........ -·-........... j •••••.• ·' ..... .. ' . . . . . . . -. . I . : :. ! ' ~ . I . . ~ . = : • . • • -~ 1 .. . .. t- t • • 1' -.. • .. • .. ""' .. ~ • • .. : . . . . j . . : . ~ • • • < ~ .. • • -.. ... • ·• ,.. • • ' I --"""-. __ l ______ -· ·--+-----· ·---t-- ..... 1:•• .. '~-H• t -- ... ~ • t • .. • ~ ... .. • ~ 1 . .. .. ... "" • "" .. $ • M <0 <0' .. .... • of .... -.. - . . . . . . . . . ~ . . . . -~ . . . . ' .. .. ... ... ... ~ .. . .. ... . ., . . l .... .; ..... . ..... ···i···~ --·----+-+ ~ • l ~ • .. • 4 • ...... •-" • ... .. ' . ' • , ·~ -+·"""' .. -· .. ' .. . . .. . i . 1* • .., 'T'• "" .. .. .. t • ,. ..... ..... -..... -... _____ ._....._ ., . ... ! .... ~ ...... .. " ... ; .... ~ ~· .. f • .. .... .. "' . ~ ... ., -. i I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LRX-3 RIVER tv11LE Cf 8. ~ q n, : 10,000 20,000 30,000 I '40,000 so.ooo 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 .. JJ ·j_ lJ 11 . ~ l ~1 l .j ~ ~~ ! .. I l f ,I ~ l ' _I 1 ,{ \ j 1 ·,j ' i l 0 • il ;~ l l j _, w > ~ 3;fo- <( w en z <( W3~­~ w > 0 CD <( 1-352- w w u. .. z 0 t=3::JJ- < ~""' w ..J w 0 · · ---· ---~ -· --------1--i · --· -----· -1 · ---· + -Bt\ \'bIT lo . =-=~-~ -·--,--=------~-=-=·-~-+-------+-'~---+-~--·--_--~"i.-_-:---_·_-== --=----=-=-=~-~=-~+-=-= i ---f ~__:_ -~ • f---.----..--. j_ :-I . ·-"--'1--.,.·---;· • ' I ' . . ' -' . . . . .-t . .i.---~ --!--4-,.--.-----~·----. "7"-· , ---·-:· ~-~------;----.-: . • • -· • ---:--+·~-: +~-~ -... ___.....-;---: ; ...... ---=-~---~ -----.... _ ----_..,.. ·------:-; :-·~r--... ..,.. -~ _ _;__ 4.:... .... ---·----·i·-'.....__ ~--..... ..,....._ ____ ~-..__ ____ --------·--. --~--~ ... '--;--· , 1 • , ·-'-· I _ 1 ·--..l.----~··-·-· ··-------------------t-----,------:---------. I j l . ·-------... ., ·----~-==+===·. ---r· ---:Et -~~:.:.. : -~ . r·--, ... -~~~~~ ~. ==-~~~ ~~~~~~;~-~-:_:.=_:+--=-~-=-=-=-· ~--~1·,: -----~-~-t--~----~-:-~--+7": -__ - ,... ----~ ·-~-----l -- ____ .1 -~~------~ -----~------------·j···--------~ --------+---------.~-------+----------------------·-· .. -----.. ·~~ --~ ... -.. .,. .. _,._ ------------·----· -----! ----~ .. ---.... -.... -.. I ... --..1-"""'"- ----,--- ------! ,..,. _ _, - I ·r. -t ·- ~·-·---· ---i----·---....... -~ .... --L---------·--·--,---·--______ ... _____ _ ---·--------+---·--··-------;---·-- .j -----~ ----:-~ ,. -. --· ,. j· -----= =·:-::-__:-_·......, __ ~---_-__ -_ -=:---=--=] -=~-==·1--~ -=.,-:-_ ---· --------· --t·. ·----· . -----~ -. --1 -·-~ --~ ------··---· -------..1-.. ------~ ---. .,._ . .. _., ---·---·-... --· --+- ... _. ,-·-.. --i--- 1 J -I . ·--~ .... --· . --' -- I ·----i i- -1 l , --. . ! --· ... ----·-·--.... ~ -·--. --_, .• 1_·-_· -----+--·--_-__ -_--_. ----·-===-·--t-----~-----'---1----· _...:. ----------'---·t-----.------;------;-. ~ ,. ---! • ,. ... -·-·· 1-..... t." .......... J_____ ~=-~~=-~-==-=-r:=.==· -----1.-~-------- . : ' -· ... ~: = ... :1_4 -:-:: :1 ~ =-~~i~· --4---· -__,_L_.:._-_:. ___ +-:._ .. -_-_=-1-~~--~-_-:_-_:-+. _:_~_ . .=_-~-::'7"'~.,./'-t---·_·_· -r' ------ -~-----=._:_j~.... -: --~-----· +-_~-~-~--~ l ~ ~-= =:. ~~ :. : ±~--:-: :-: =--=~~-~ j-. ---I . --~ : -= -~ ~ ~ - ··--·I _______ . .:.__ ·---~-------·------~ ·-· :.~.J.~~:-':.·.:-.j---· _. ~ -i · i · ---r-· -·---· 1 ---·-• iJ· ./"'_ -· ~ · r · ----~- i ·=·-· t ~ ·:-=~-=-~=-=~-~ = =~: .-~--~-= ·= • 1 • --• T -....__ -••_:;;.; • ---• •• •• • • • .l-- 1 --1 f ---.-,_ ___ _ I -·--1 . -. --,..,_, __ .,..... J ~ t 1 -----------z:_-r------,-------·1 --t •.• ---14-/' . -------1----~-~~ j ~ ~-=--=---t-' : .. ~ --~-:.=4 .. ~. :~~ ~; =-=~----i . ---.. -1-... --·----i . ---· -· --·-. -----~ --••• T -• ----·---·------·--•· •- ... -·-··---. .. . ----+-------- -----! E-"-~--·f----·-------r----· -. .,_1 ~ ---_...!._ -----.,. • --------- -· ... --1~· '..,--·~--------~~~ ... ~ ··----~--. jf :· :_:. -·---!--:-:~.-: -::=-:-:~·---. ·::~:-:=-~ Q~i::R_'(t:p ---1 · -· ·--·--r-------'--·----'-·-----f·-···--··----T ----.... . '1 • • ___ ;_ ~ ; .• --l-........ _ ... _t-----4 ..!.._ -~ ----' .! • 1 • - -------------~~-~----~----I l I J ------ - -----~ ·-·-··-v. ---. -t--·--:--t-·---..:. __ L --. -----...... ---· ·.-:-=~~ li ~ : : . ~ - -~-=-: __ ~! ··~/ :::: 1---=-~ : .. :· :~=::·:~~=-1 --~~~----. --· . -.. 1 ~ -_,. -1 " 1/ ~ -o·-:-+ .; -! I -i ·-" ,;.._. +-· -'• • •••••••••••••••••••••••••••• =--z·-~ ~ ~ ~ ~ ... ~ It 1 .. . ·--. "' - I • -: ~ . i --·-· j r .. ...,.~~ ., .............. -~-- y-• .t .......... .! J I -. ] __ : ___ ~ : l . -~ . -.:.4.;. ·~-- ·-~~ ...... ~ --... .J...... . • ~ --l -:-·T~ .. ...;: ,,.. -.,,. , ... ~. ~-,.. 1 ..... i _;. ~-~·_., • • ' l -·---.1-f-'---~+-, J f I f : . . . -.. -:..... -~r-r·-+rJ-tr: , ""' ... ....._ "!-- • -~· ~-! * ... l • . ---+-... -i . -"'t-~--· --. - - + "1 --·-• _j_ • ~-~-~=t:~f . . . j_j . -~ ·y·-- . -; -:· ·:- ·~ -i--1 ~ " o I 1 .. LJ.1 "'J.l...!-4 -T--t ... -. ..--"T• .,. "' ... J ~-.... ~ SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE L'R.'t-4 ·RIVER MILE I 10,000 ' 20,000 ' 30,000 I '40,000 ' 50,000 60,000 DISCHARGE, CUBIC FEET PER St:COND HARZA EBASCO JOINT VENTURE OCT 1983 1 r 1 t ., ,, " r ·~ ~ lr; ,, ~ ' j ~ . , f~ ~~ l\ ~ I i' q . ' ., l' ~ 11 ~ A f5 }~ j ..J w 3Lo4- > w ...J3{o0- <C w rJ) z <( ~358- w > 0 m <( 1-35ln- w w u.. .. z 0 -i= 3!:l.4- < > w ...J UJ 352. - 350 - 348 , .. 0 .............. ~ .................. ~~··· .. .. -~~~~~~ + -~-~ i ~--.:.:.·~-=--=-; . t -~_:_-=-~j· .. -~·~:. ~ .~..: ~ 1 .f;~~\\J\\-; .. -.. -. _1 __ ··-·-!-·--··-~----:·--·---·--··. -··t-·· .. ~---· _·_-__ -_· -~·+-· -· .. : . ..:....:..=; ----·----·-----t-. -· --··--~·--. --·-.. -. .... . ...... ! -• ,.. ... -·-..... -r-·-;~--....... ----..... ~--'""T'''4""----·-;.._. -, .. -~.---~-..... ~ -··--~-... ----- -~ -.1 • "'\----. ...,.. ... _._,__,_ ___ .. ~ ----·-~ ,. .. .,. -·..---;--.. ------1' "'"' ----~ ., ... -._ .., .._._ ---_,_ ~--,...-+--------r-___,....-1_, ___ ·-.. ---f ·-: "' _. ,,. •T ·-~ . ..! -·-___ ,. :----.. ---~--+ -----t--·-~-......... --·--~-... .......... .... t ~ - i ----·---+----~~----7-----~--------.. ···-·-i· ... -· .. -·-·--·:::--_· =-~==-.:.~~ ~ -=-::~-~-. : -1+ .. ~ .. : -~ -------~-1 ....... __ .. --·· ..... _ ·---· 4 -: ·----+ -·--•. -••. '! ··--·----·· ~---~·---'"i . .. .. . .. ... -+ J --'"" .. " .... --·... .. ... • • . -•. -~ ! '"' .. -~' . --. '. ~~-l ~-~~·~·:=·~~--= -~ ~~ ~~--~=-·:_ ·_. ---i . -~----.-~-:--·-. ---~ -~ . ' : ~ j = :-:_:-;:: =-=~::J :. =:-=~: : ~.:J _:-=-=: 1 : -1-. - ·---:·----1 ._ ___ .,. ...... __ ... ' ---4 ---~-_ .. . ---~ .... j ! . --·----.. i . ' . . . -.. ~1-: --~-~-=-~ =· --~ ~ ~=--~-= ~:~. ·:.=~~: . . -.. ~ .. . ------------·+----·-!-· ··-·· •· • • . . . ~ • -; ----. .. -.. .;, -· ·--. • -'•., I .. . .• j . • -· . ~ -. -... .. J . -....... ·*--. .. -...... •·=t-. ----.... -I · · --. · -·-t · ---. ----· --· ·--· · ··· · -· ----· ·, · · ··--· --~1·-~ ~ -I · ... • · ··· i · ··.-----..... __ .,... ___ ,. __ ·-----. . .. i --. 1 ~ : . 1 -~ . -. -: { :_ -·---= : . -~ - : .:.:: .. -. : -. i i : I I . . l . . . J . .. . i -. --~-. j --"'. .. -• l . . 1 . • • • • • .. 1 • • : . • ··• -·1 • ..... , I-• . . • . . 1 • • . . i 1 • • -... ·-· . -• --r. --. . 1 . --• ..• • 1 • • __ • _ _ _:_·-.-1--:-..:_:__:~_: :_l_:.. __ _;_ -' --~v: .. _.J-____ ... ~ ---·- -~-~:. ~ :1·1: ~ ::: ~ :: :·l::: ;~=-~~.:--=-_:~=-~:.:.: :1 .. 1 -·· ---· 1 --··-i --r·----i · ~-· i -· ·-· · 1 -· . . . - . . l . -. .. ---_.. . -·---t ... -- .j •. ·: .... • •. ---4. -------. ·• .. . . • . • . • -• • .• • . ... -·· ...... -t ----· ·• •• --1 . . . . -+---_··--·+-· ·_-_·_· ·_· +----_-_-_-_ ... -!-------·--~-----_··_·_· ·-···_··_-_· -t----------=-=-=l-· · · -~-.. ---.,.. --::: .. _ r-----:--------·----t --· -'" ··· ---· · · · · ~ · + ----r----··---.. __ 4 ...... --t .... ~-~--.. _ ...... "-+ i: -___ ,_ --~~--"' L. . -' ~-::: 1 : ~-.: ~:: -~. :.: . :=:-: +~--::-:· __ J ____ _ ' •· .,._,_._ ..... -~ ... ~ ---- ... " . ··---. --~ -·-·--· ------r--·---··------+ .. ~ -. -----... .. -.. -" .. .. l --.. -1 .• - .. ..... .. .... . . f • --~ --·· _ ................... --· ---+-~-! ~! ..... --··· ~ ~-~----~----·~·------+-----~·------r-----~---~-r--~~ --• .• L~-·~ ... -· • -. -+ -... -.. .. -• -· ~ ' -. , ..... .,..., .. -· ~-... -- . . . . i . ' . . ! .. .. -.... '1' -~ ''"1' ...... .a.~ , ........... -..... --·--·i·· --...... ·---t----..j_ __ +-----r,-- ~ -. i ! : : : ~1· -·-·-1· ... ~· ' -• • 4 ' • -• " • -.• ···-r ... • . . ' • <t .,. ..... .,. "'""" .. ~ ' t • t ... I . .. 1 .... .o; ·-.... ,.. .... '1 -..... " ... ... """ .. ! ~ ... ·t -~ ~ . . . . -r • ... ·- .1. ... ~ .1· .. -;· . . . . ...• -.,..... ~ ... " .... t .. "':: -~ .,.. ... ... ... ~ ... "" ..... "' • 1 .. 1 .,. ...... "'(. ----.~~--;-----~ . ··~ • ' ' < j i . j ""' r • -i ..., ~ .. .... .. -4 ···"" .... ! ~-"' ., . • ..... -. ... -· . .... -+ -t , + -4 ., - .., -I • i -~ 1 j, .,.J " ""' • ' . I ....... : .. ~ . .. .. .. ---··· ...... . 1 • • SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE LRX-4.3 RIVER MILE /00.17 I 10,000 1 2.0,000 ;»0,000 I '40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND r ~ . I t 1 a !'; ·1 jj ;) .I ,, ., J ! ,, ·,_. ' .,! ~ I 'l ' ! 1' ' ~ ~ " ' ' q i " ...J w > ~3lo4- c( w r.n z <( ~ 302- w > 0 Ol <( -.. ' '\ ..:. , '-J---'W'-.l w w u. 354 - 0 . . . 4 . • ~ I • ~ ~.. -.. ... ~ .. . t .. • .. .. -• . ... ... ~ " ·•· ~-l --• ... .. .. - - . --. --- . .. .. -.. I . :j·l ·-~j: ... -+-----~·~----r-----~----;-----~-----+-----+~-------·-t-·------;---. . --.. I . . -'--i ..... -·;--· --·-· --.. --T ·-. .. -.. -••. • . . . j . + ·~ . -····4·----·--~-----···,··· :: . ~ ::~ ~.:··~ : ... 1.=~·~·= :: -~ ~-~:-::::~: ·:·--. ; ~:·.I . ·---·-. I ' . <t .... t . . . i 1 ' • .. 11. ... 4 " ... . .. . ~ I .. .. : ' .. -.. " -· ..., . . :·_,: ·w· ... ·:-=. . .. "" "" ~ "" ... . .. -.. "' i .. .. . --+----+---...--· ..;:,._~ -·-r---- • .... .. .f .... ,. • ··1·-·-····-t -- • ... .,.. . ! ' " .. "' . ~ " .. . i . . -• -1 .• SUSITNA HYDROELECTRIC PROJECT • • -... 4 -i ....... ~ ...... _ ...... , ......... ; . 1 STAGE DISCHARGE CURVE I .... ~ ............. "' ... 1""'~"1.... -~i··· .. " . .. ~ .. ! .... " ~ ~ '1' ; t . . " " .. -T. ·• •. ~- .. • .. .. ... ,. .... .. • ! .: ... ! • "" .. .. ' .... .. 1 ~ ! . "" " .; • . "' i ; .. ... ..l '""" ... ... ... J • ----,-I ·--'-------+-·--.·~-f-r-. .,..__ . -·-,--. -" ' ~ .. • • "" ot 'I • "' ~ .... .,.. .... of • .. "" I w --t ,_. .. ,. ..J ~ !_.!, __ _, , ... ,..1 ....... .-.-r"": ,_ ... ?'..f .... ·~1.,. .... l ! I I 10,000 ' 20,000 30,000 RIVER MILE 100,8 I '40,000 I 50,000 DISCHARGE, CUBIC FEET PER SECOND 80,000 f I ' ' ' ..J w > 37Z- ~370- <( J.U C/) z < ~3~5- w > 0 CD <( · _ ~ · --=~~-1 _ ~ -= -i ~-~ ~ . .-:~---. : -~~ =-= .. -~ ~-~! ~~: : = 1~m\1:liT 9 ... ~: :· :·:~ ~ ~·=·=: .. ~ ~--·: = = =-~-~ -~--1:-=-=~:.__-.: .. :=-~=-~ -:. . .:-. .:-. ~-. ~ = .t_-:. :.: ·----. -------- . ~--~~~ -~ ~ ~ i ~ :·: ~ ~ : -~ ~-~~ ~-~ :~~·~=:=~=---~ ~~=~i-:-=:.=1~ -=--~j. : : .. -~ -; . ~ ! . ' . i i I .. . . ~ -. . . . . -. . ~ . : . = 1 =. = -: . ~ --~ . : : 'j : = ~ : -= ~-~ t .. = . ~ . ; . j: -. : . ~ . ~-.-. .- . : --: ~ :~JI .. :~~ ·: : :-~~h-~-~~~:-_ _;f-:. : ::. ~-:.: 1j ~ -~-.: -:_:_-• 1 ~.: .:. ~· . :.:- ~ : . : · ' . . . . ~ 1 . . = · ~ . : . : . . . : + ' . . ~ . ;. • : -----~ ::-: ~ . : . I • . : • . . -. . j . , . . l -. --. -r ·--. . --. ·--. . --. t __ · ------ . . . . I . i ... I ... ~ .. -: .. -1--. : . l . . -i •... f .. -.. --1 · ··---·j · · -•-· -i · · · · I · · ~~~-.. : :_1__:~-~~.: __ t_ __ -~-~ -~~-~~~~rrj_:-~-: 1 ·--· ---.:·:::.:: ::: ~~-=--1. _:··~--+=-=-=-=-~.:~-~-:-.. ·.·· -1 .... . ~ . . -. -~ . --1 . -. : . . -... t . . .... -. -· . . . . . -. -'1 . . . -. --i . . ---. ~ . . - . --. -. -. . . ·--, . . -· . i . . -. : 1 -1 -•• , • .. • 1 ---• 1 •. --i .. ---~ ·-·-·· . . ----. -.. 1 . -. ~ . -i -. . ' . . . I . --~ = -~ . . : . : . ~ . . : t' . . . : . : . j . . . : . . . .. . ~ .. • ... ~ ; . -... ----.. . . . ... . t ~ . . . " ! ~ . . J ... • . ... ..•. 1... ' -----~ --~;-----+ -_-_ =-1---.-. . . .. : -.... j ~ -=-~~~--~· -=---;:;---'_j i ··= .-· ~-- . . . . . ~ : ... ~-:·= . ~ ~ ~J : ~ . : i . ~ .:. : : -=~= r: .. ·~: . . . -, ... ... . ... J + ---., .... -... ~-..... . .... -• .. -... _....... -"'1-• -.. --.. • • -.. ! " • • _. I + t ....... •· ·I·······-···--l -·-: · · .._]&,&;-- w w u.. .. z 0 i=3~4- c( > w ...J w 302- 300- 359 0 - j ·-·!··-·u······-·-··-----·-l·-· · . : I: .. ~-.--~--~:;,L_:·-.. ~--··-·.·:~.-- t . . ----l--o----t---·------i -· -----t-------; ------' .. ~ . ' ·-.. -• 1 ~ . • : ~ : ~ [/f': :·--: .:=~= ~-:-:. ~~-j ~:~ .. ~ i --... ---.. . . . . . . .. "' -. ...-.. . " .. . .. : -1 . : :~ = * •• 1 : .. : :. ~ --~-: : ·~ ·~~ = :~~: .~--. --~ ; "'~ . ... ~ .. . .. . . / . ---r----+---' · : / i • -i . --··-.... ·1· -·· . l -~ . I . . . . : : , . . . ~ :~· . : -8 .. -~ . -~ ~ .: : ~ r_: ~= -~-~L~ ~ -:·: ~ ~ :-~ -: : : Hi . : ~ . . --: .. ....... .. .. ± - ... ·--::--__ _. .. · .... i ..... ·j. ---..... -.:---. --~---.--..... y ... ·····.···· ....... l, ... i .. ···:·· .. • : .. .. . ; .-.. .. t ,. . . .,. .. ... ... ... ' . . . . .. ... ! .,. .. . .. ····· .. .;. ··i· : . ! I ·--.. .. . ... • .. .. . .. .. i . " I f I SUSITNA ~~i_j ~-~1.:~.:.: i..:.: _J_~-~ · L~ , , • • • , I • .1 • •-1· • • ·····-..... · .... ~ ·~· HYDROELECTRIC PROJECT I t ' • • .. • • . . • . • • • • • '1 .• • •. .. ., .. • .. ... • .. ...... ,.. .. "1" 4. .. ... .• .. -'I i ...... • .. • ... . + .. • "'f .. .. .. "' • .. • i' . .. t. -.. .. J .. ~ .... ! .j .... '! • ... • • .. ~ ~ ' .. " ........... ·-1~··-~ ...... J .. ~ .. ... ____ .!..-..... --+... -· .. __ , _....,. ....... *-r'~"'-1---·---+--~ STAGE DISCHARGE CURVE LRX-to ' . ' ,, ' .. .: ........ ~ .... ~1 ... --·+•.f •· ! • ..:.~~ .. J,.1 ..... _ l I ' f ... ... .. .. ... i .... '( ! • '"'~ + . .. • t ., • ~ ~ -- l 10,000 ' 20,000 I 30,000 RIVER MILE f 00. 9 iJJ I '40,000 I 50,000 DISCHARGE, CUBIC FEET PER SECOND 80,000 -~#'~ ,::.r-. ~~?,· \.~~-·L 'A _q I , .. ~----------~--------~----------------------------------~------~----, 0 0 0 n, ___ _ I \ tl' : ' ~ rr ·- J -~ ' I I !'"! •--.-~~ --~ • • r ; --~ -~ ' --] ' • • a t I •• l I I I ' I : r I ~ • : I : I I I I I ! I : I • • : I ' • :I I I r I' I ; _.,....,I ,It I;~!' j'l} '!''! !~·1· I~! I • " :· j~•t !l 'i, • 1. 1 1 • 1 • 1 I · I l I 1 1 • I I 1 1 t 1 j · ' r ! 1 1 • • • • • • • • 1 1 I f p 1 ' • &.-I I • • t . • I Y~:· •til li'! !I r: ,,, f • ··r~ t•r· ~ :· ·• · , tt ,,t ~-• T-.. -:--r r-r T +-t--.---:--.. -·~ .. --·· ., ·;·1 -.-,--; -~· -I" ··-~--·-.-r. -~ .,_ r ·r· ~--! .... • ... T f ... • ---· .,... T T-.- ~ .... , tit tl <I I ltft t•lt •• ··~f1 !•I • tt I I I .. • t • . I . I I I I ' ' ' : : . I I I : • I • • I ' I I ! ' I ~·1 ~til' jlr; 1·1 1 ! , t · itl :,. 'I rr• j;.lJ, I I ·I i I 1 1: ~: •• i I I t I I . i i --:-i : . f i . I. . 'I • I. I : . ' . I I • I ' I j I I i . . . ' I I . ' .. t ., ... I ' • I • I ' t ! I , I .. ' • -.-I ' ! I . t ~ • I J I I t -. 1 r • I t ' 1 1 " ! ~. -~ ... , .. ,.. ' I I I I : ·: I I i ' : • • ' • I'. I I I • I ' ' I I ' • I > • I ' .,1-t . ··H-1·-.---rr·-r-r· -~-... -1-t-. -_ ... t-+-+ .. r-r ........... -r•--···r ... 1-,. ~-.• ,......... . •. ,.-r .. ,. ., .•• ,. I I I I f t I • ' I I I ' t I . . .. ; I I . 'I; i' I' l ! I I ,. I II ~~ 1 . I' f I II Jl I i J ~ ~ 11'1 .,. ; 11 ,, I l ! ; ~,· : ,.. i ; I I I . I I I I .. I . ' I I . -! I I I I . I I I I I· I ' l I I I I I I I I i I ' I I I i I I I . ; . I • ! I ; I I i I t ' I I • ~ I l -~ t 1 ! I . t t I ' I I J • :. ,, ·~· I [r{r-r j'' r 'I i Til~.; ~,·r I i ll .I if; j' ; ! --,; ~,~ :1~-~ i ; I l ,~ ·,. :.·,~ I I' . ' I i' I _, I I I I . I I • I . I I t ! ! . I : I I I j -~-' ! · 1 i·l !'It·· 11 t!.:: lit• 1 11 · 1 !11 l . . . I I I I . I • t-I • • I . , r ' ' ' I I , 1-. Jl .L 1. JlJJ i 11 r ,-~ -r-ftr -ITH-rr 1·-~trr, ·1-: ~ l t :·~ tr!r I I t 1·111·!111 ,,. I I. II l i j I ! I II i ~, ! I i ; I· ,, 1, ! i I l I ; I I i I I !I' ! : I; II ; ! I I I I ' ' : . I I I • I l I ~ 1 I' I I . ' 1 I ' I I 1 _ _ ~ _ , I I : • . I , . 1 • • 1 I 1 • I-T . r-i 11 I 1·!-H' .I r l I 1 ·-:p·r i. i i ' I : , • . , 1 , r . : I I . < z t--en :::,') en 1- 0 w ..., 0 a: 0.. 0 -a: .... 0 w _. w 0 0: c >-J: ~~ o· : ~ ~ 0:~ c(~ :c: ~~ wz CJ~ <~ 1- U) ~) ...... • ' Q ' w _. -~ a: w > -a: -l-, ll • I . I I j I f I I i I I I r· · I· i I I I j 1 ; . I . : I . . i I I· -· . . --~-.,.. . jJ I .!. , f I .,_·! r ' ' I ; ; l~ ' :_ ! ·:· j: :fl_ftr~. ,_ t- "1. . .. - . -,-_ r1-~-·I-· .. T rr ~ -~ ·r;. .. 1. ~-~ I I t 't· I I I I • j I I I ' '. I ' ' l ; I I I I 1 ~ I I I ·I ! . t I' I., I I ' i ! I' I I !' . ' I ' I • • • I : .... ~ . j .. , . ~-· I I I ! . ~·· l I ! ! . I I I ! ' I : L I ! ! I·· I ~I I -; : i I I -. • . I I I. I i I I•! I I : I I • 1-,· ~-~I~ I Tml' ·-r-rr,l--1,~ . I rr ; I I I ~·rl'l fTTr II ! I I i ·l TTt·t·· .. r· 1 .. t . 1 , I 1 1 I • 1 : : ~. ; 1 r ~ ' ~ i , 1 • : • 1 • • ~ -I 11 ., . . u· t·· . i 1' ~ ! ' . . : • : ... . • . ' I ~ I ·t ! . I • • I r . • • I ~-· I n --r-+--:..i-•.•.. I !•·I-.,.-•·· . r-rl -. +-r-r--:-· ' .. ,_,..~. 'TT '"T 1-!'--j·-t---+-1-. ...,........ . -..-,~ -r-r_ ;- . . ·I·. I I l ! ' I . ! I : I I ' '1 ' : I I ,. I ! I •• I t I r· ' I .. I I I r . -:-T · · I I 1 I ·I 1 1 f 1 I 1 ·j t • • l 1 -1 • I ,. • , 1 1 r : , ; •1 'I • ·I t 1 1 . . 1 t ., I -1 1 I 1 l1 . , I ; , ·: , . : . , . ; . . . , l.~ 1 1 •. 1 1-1 ~ ~ 1 1 • ·1 i t· i r !-~ :_ , . . I .. 1 ·1 r ! 1 . I I I I -I· ·: : ; : · • ! · .. · • • • 1 1 r 1 1 ' ' • I· I ,. 1 • ' : • · t , -• • ' 1 • ., . ill. . . . I . , . I· .,.,.I ,, rtt" i:•·l ••t·r· I •I 1'1 lt-·l~ -+·t·+·--~-···· • '1 . r .j i·l· I . '. 1 • I • ., ' ··-·. • ' 4 ·I • : ' .. . . • • :· ' • ' I • ' ' • ' • ·r .. ~ ..... i . i ·t·-1-·-...... . 1 ,r .. t· '! r~i···1 •·! ,.,,. r·i1:··li!1··1i~: 11•· ·••·1 t~·t· r1!•·i·· • 1' . t I I I ' I I . I ' ! ' • ' I I • ' • • I •• , ' t I I • I i I I I I l '! 1 . I : I '.: . I ' I. I" ' -11' t : • ... "'TI -r·rt-+-1·1-1-r· . r1• ... --~-+-r··--+-•--r-,-, ,.,.....,... -·r-t-·---~-_,._ -·TT-..,.........,...... ...-~-r rrt-+Tti --~ ·r . I I , , 1 , r f • l • . -• · r • • I 1 • 1 1 1 1 • 1 ·• • -1 r i 1 1 1 1 t-• ;. • , • • I 1 1 1 l 1 1 • • ·r ·• . ·-'--· · ., - I I I . ·1· -.. ~ "f II i I I Jl I ! I j I l t .. , r' I J t : : I ; 'i .I I r : I I I l t I' ! ~ ·I I l f ,.,_ tl-. ! . -• 1 1 1 1 • . 1 . 1 1 I • 1 I ; 1 ., 1 I , I , 1 , 1 , • 1 · 1 ! ··I 1 : 1 . .,. , 1 , · r·l· ~ • i I I \ t f 1 • f t , • i • t , • I • I T ~ ~ l ~ I ~ !t:• ........ -... "'~""'"'-....~ .. · T r I -1 ( -.... fCl M "-1 ' A I ~- 9 (Vl· -~A rQ If) r'l ... 0 • 0 0 ~-o ... 0 .., 0 0 1-0 ... 0 ~ 0 0 0 • 0 (,'I) 0 0 r-o .. 0 C\1 0 ~a • 0 .. o· • c z 0 0 w (I) a: w A. t- I.U w IL. 0 -Dl ::l () • w C) tL tC % (.) • Z5 "---•!ooot .-,.·'",,.<"I l _-;,;-1..··"'·( ~:~:~}~;; 1~-:r~ t . ::;:" . l I ' i l I lc '· l - [ > l I " t lo . . F· I . ; -:;,,, r~ ('t)! coj ·--· a.l·/,.:-,_~ .... l ~-•)'• .... -:·)i t-};~ or -~"~~~·"':::::.:--~::-::::r-·7"~~~----~~~':'~-. :.~--:.~:===:··-=~:o-==----:=-..::==-~----,.. ··---= • • Qt -• • ' -~ --·--•• (. . . . . •. ·--· • .. .i ·' • --~-... .• f . • , . ~ Iii , II,• f .: I. I. I I I I ·I I· I I I I I I . . ~ . . . . -. . . . -~ . -. . ---. -J . ---~----------~ . . . 1 -. . . ~ : : :·1 ~ J -~--_: : ~-J~ ::;~-A~ -:: :-~-:~ l : ~~-: : __ -j_ ____ ~--- U: .. . . 1 . . • I . . . : . . -.. . ~ -. -------1----... -. --. j· -. -. . j -, > ~-: -· .. -· · -: i . ~-·J ~ -: . · :. : 1 · = ~=--~--~-~--~ ::-:-~ : . -_. I - W ·-. l·. ~ .... 1 .. j ...•.• J .. -----'1-··----··· . t·· .... 37 ') . - ' --·---- ....1 L --_ - . 1 • . i . . . ! . . < -• --• -----i ---· · · j · < _ _ : r : : : l : --: · · ~ . 1 ~ . : = . -~ ~-t . . = -! -=-· =· £· : .: ~ ~ ; · . · · . w ... : .. ~-J__:-----~· ~-' -1 ... J .. _ ---'-·1--. -·- (/) . ---~ . . . ~ ~ -:-=---:-:-: ::--:-i--·-~ ·-·~ = ~--=-~~ -~~ '1 . ---:-:--··-. ~1 ---. -:··- ~ 3 7 0 -: : i . : : 1 : >: . : : ~ . : : . : . : -l-::~-: :::=:::: 1" :· : .: : : J :: :: ~ -: : : : :·: J :: : ~ = : : = r --~ ~ _: : --:. : : -: > . : : : : : : -J : : -: : -- ~ : ; - -: i : : :-:.T.:.:-~j-: -~ ; : :~ -:-f~-: _:; : -:-~ ~-: ~-= : ; : ~r:---: ·-...., . i . . ~ . . -1 . . • . ... -~ .. ~ . . . -f -• -. ' . • . --· <( ' ": 1 • ' . · j ' --'-~ -. ' --·. ' t· -· -T · • · -'I · -· · ' , 1-3 to B--.. . .. l . ' ...• l . / ... -. I . ·:-:-~ : . ~ . . . ! . -. . w . , --.. v· ···-... , ............... J_ ;· -1 .. 11: ~----_i ____ ~---~ ~-_·. :: .. :-.: ~ :::. ~~-=-~··-. ~ :. -~: -~~~----· _·· .. z 0 ;:: 3l£,fo- < > w ..J w 3/oD 0 -. l l . -. . • -l -... . . . .. ----·---..... l-• -. -• .• • ; • . . •. .. . . • . ! I • . . . • -• -.• -• . . • ·-.••. •·•• •. -""! •.• -· • • -• • • • .. .. .• -i . -. . • . . : ; . . : . : . ~--~ . = : . . :!. : .. = ~ " : ·.::_ ~ = + -:-: = ~:· :· : -. ---i = -: j ~-. : -: • - ~ ~ . I • z· • • ' ., : ' : : -; : :· : ~ t : :.:.: = :: : -:.: : r • • -i : • • : j • • : -• ·-. 'l" • .. j . • ~ I , -. -· -· -.. . . . ' . . . . ~-~-~ =-~·t-;-· .:.:-.: :..i. __ .... ~-~-~-.:. :. ~*-: ~-... ·•· ; ~--~ I --:--~-:-:-• ---. ; . •• . •. • • ~ . -• . -• • ~ . • • .. ; • .... I ·--. ····· ... · -··-·-· ····l··. ·····-. ,. ! .. .. . • .. .. · • ... .. -4 "" f e • f "' . . . . . . . . . . . . . . . . . . -------~-.. . :·:;: -: . ~ -.. .. 1 ; . • .. .. : . • . ~ .. • .- ...... f.. ... • • .. .. -" -... : .... ... .. • .. ~ .... .. 1' .. -1----+-·----·-----· --·-·-, -- . '- - . I . . . . . ., . . ~ ... - .. ~ '"' '" '"i . • .. .. "' -.• - 1 •. ' . .. • .. '1 ... "' "' .., T • .. ' ' "" ......... .. ,.,, -.. + .. ,. .. . . . l .. '1 • .. . ... -.1' . ·.-:- "' .. .. '"" ~ .. . ... ! .... . • "' .. ' ~ .. '"1 • i i ... ,. .. 1_ .. __ "' -t-.. ~ 1 -...... ~ .. • -4 ... ~-1 . -4 .. ""' ........ ~· •i·-t•·~ ............... ~ ..... - __,.. : . -~-~ . ..,.......... ~----..........:- • ~ • " I ' .... 04•#:, •t•••R· ..... "'t -~.f+f"1i+••• l • ' • • • ... ........ • ... -of 1 ""' ..,.~ ... - ~ ... • "" ... ... .. ; , ..l 1' ~ .. .. ... ... • 'I • .. •• I I I SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE LRX-7 RIVER MILE J Q /.52. : 10,000 20;000 30,000 I '40,000 I 50,000 80,000 ... DiSCHARGE, CUSIC FEET PER SECOND I I I I I I I I I I I I I I I I I I z_il -JIU'J ...J w > UJ -.~" ...J i-. : - ..... - w > 0 co <(3',...... 1-0'0- w w u. .. z 0 . -7;. 1-:;: IJJ tv - < > w ...J w 3(o2- 3(o0 0 ' . --.i !, -J • • • • .• -·--• • • •·· --·•·-. • . i •· . -~~ . . ~ -i --.. L--.. ----·-·· -... -~ -------, l 1 "" t .. .. -• . .. ~ ~ ~-:~ j -~-:~ =: i : ;.=~ l-: : ~ E:~:~ <~:i/~: . ;~~-: i --: Jl, ·~: ~---~-----. ' . : l . . . -4 • • --• -• -·· ·'--• -. --·. + .. . .. --. i • .. 1 .. .. .. ... '! .. .. .. . . ~ ... . .. ... -• ""' .... . .. i ... . ---+-----r-· ---~ -----+-: -- •·!·~--::::.1-~~ : : ~. l ~ : .. ~ ~ . ~ .. I . .. -~ . .. -.. . ~ --. SUSITNA HYDROELECTRlC PROJECT . .. .. .. ..;. • • 1 -• ..... .._ i""' • -.... ·• ~·i·· ... -STAGE DISCHARGE CURVE <1 • ... r· .. --: ; ' .. .;. ... -~ ·• ..,. '"' ·---i; .. .. .... .... 4 1 .. • "' ... 1-~ ·t ~ ,J -'! ...... -4 . . . • .. • .. ... .. .. • " • .f 1 -:" ... 4 ~ ~-+~---~-+------~~-~~~--~~--~ .; ·-.! _,! .J -.. ... ·i-·~ ! ··+-+o-·~ .i .. . I ' . • ... -.... -t ... ~ ~ "' ...,. Il ..... .,-:--;·· t 10,000 .f -·• J ... ..f ~J ., l ,.. I 1' ... <t I 20,000 t ~ " .. • . I 30,000 RiVER MILE 101. g I '40,000 I 50,000 DISCHARGE, CUBIC FEET PER SECOND 80,000 I I I I I I I I I I 1-, ' I :1 I I I ................. ~ ...................... ~----~--------~·~·._ .... w ........ ~aa._ .. ._._ .. .__.--.m~---------------------. l ..I L1J > w ""la-,d. _, -LT\- c: w f/) z < w "382.-::E w > 0 CD < ~ w w LL. .. 3BD- z 0 i= ~18- c: > w ...J w -=----1 ------, !.-----'l ----< ---~ ~' . -.. ---·+-----+----· "'t'-----·--------1 .. -~~\£)' .---4 __ _;_.....-i ------· .1--~---+-------t--,.-.---1--· ..... ---,f------f-----+ -- t ~-~ 1 . ---. + 1 ~~--•• ,----+-·-·-----, --------····; ---· .. -.. --· ·-·-'-1 .._ r---·-·--i .. ·------~---... _ . ·---=--· .. -. , .. -I , I • ·---• : ' -. -~~t-·.., .... -:--·---~-:-.. ~ ... --+----·-·:····--:-r--•-i--t ---r~ ·-------1-~---i _______ ,.= __ ~_:-j''~·-::_--: _....__ =;--------·' ----1-----+----·-+ ----~------f---·--~ ---~ . t •• -·-___ .. -----· ---~-------; -~ , --~ -----'1 -----+ ! ---"T---·------4-----.L-----f----·--+------;---·----4· -~--~ --·------+ ---~t--·-------t -----,----· . ~ ' ; -----~ .. -----... ---1 . --·----· --·---·----=-~---·-·-----L-'----1------r----~------+-----~-----------~r-----.-------r----------- --~----. -----; --·------t--·-..••• . . ---,._, ·-----_., ----·· ...... . ·• -• ----· .l -----..._ • -__ .. ...,_,-: ---.•• • ~ . • •=-.. J --T---... • • ----- r. -~ ·-· -----• --"·-----·-·-. --· • ·-- ----: ,· ----..j -·--"! =-• •• ·-----·-=-= I -• • •=-•= ' I • ·---· J ... ~ ---___ L_ I __ ___,_-______ ,. -------·----·-1---------------~ - --. ·• --.... -----·-----~----~ ----·---t----··· .. ----~ - ---,--• --·--.•. -4 • -·-----_,_...,i_,-·-·------------_____ ._- --'---·· ----··· • . 1.---, ••• -·--·-·1---·--r-----· -------+ -·---..... ···---- ---._, . ---·-. ---.--· .i ----- --__ . .:. ------·· ______ ,..: _____ -----.. ---·--... i - -~ --------------,....-----.. 4---:--j .. ·-·: '----- . -! ---. -·----·--l . .. --_, : 1 • . ----,-·----r------t------... ~--~ ... --· -~ I -.. --1 ----·--.. . .. 1 ----·-. .. - - -..: --··· -------... .. . --. ! ---· ---, . --. ---,· ,_ . --·- . -. -~ . ~ ... ----·-l •. ---~· _ .. I -, -I .• -···-j ----·-.. -........ -~--·-+·-.. . ... -------=--_,. +·---.. -·-j --.., -· ,. -------·i-... ·-.... --..! .... ·----• < • • '1'·--: --,-_, ____ ~---.-~-.·--------·-~~---~!----~~~~~--.-~.---_--.-~ L-.-~-:~· ----~ ------t--·----: ---"i ···-· -- ---'j-''' . = .. ~ ·:: :·=--=-:-=-:. ~--=--· -~---:__ . -. ·--.. ---r-·1 ·t --·-... .; ... _ .. -- .• _...._ ___ j_---- ., ---;---! .. ----------~ .: .. -- ----'T -·1·. -•. -----.· 1-. . - . -t ---·-t-----. . ~. - . ---• -~ ... J ! -. • --~--------·~-..: --t' :. =·:-=: j~ : --~.-: ... -.. ~ -----. -. r ---. --.. --. ... ----j -·---~~---·--~·--·-----·~ ~--~~-----~~~· __ .. _·-----~---------~-~--------~~-----·~: __ --;·-·--------~~--- . i ---. ~-·--! -·. -··; ---·--/--+-. ---- --1 --• I -. · --~ --------j -----! -1--.,..--1 . ···---.. ~ ------·-;--· I<' -.. ----J . . . . - . ---- . -.. - ---/I-. --· --r-.. --- -~~ _------..-___ -_ _:.....;-~ ~-r---:0·; . . ... -~ ~--~-=-.:--~---~ -~ ~ -:-:-:·:~ ] : ~ =-:-~ ~--~ ~-:= : ~ ~ :-.:-~-----1-- ·----~ . - ----f - ·----1 .. -4 -. , .. --~----....... ~-. --.. ···j- -·--: .. --·-~· -~---~---··-··r -· --· I ' ~---• ---·---t·. ·--------------~---_____ _:...,. _____ _ .... -·-. -·-=,~r---~~--------·---t -· --- ~ .:-: - -w· -----...!_ --------·--------~=·---J. ·----·-•• 1·-----------. ·--- ---··-'. -----··-. ~ • ··-• -----· ----·-_ ••• ...! -1 I • ~ ----~·. -. --• ..:.. --1:.---·---T ---~ ·-· -. ·- ·---~ ·~------ -1 • ~ --'""" ---· -. ., . . . . .. ' --·1 ----·~-. - . -1 ---~-• • .--f--; ' . --1--.. ; , - _ ... ..: 1 .. . . xr-i <. = : = _ 1·-:--=-__ ~-- .. ··--·--.. ; ~ __ _... • -· f i -·-·-·-·-"--t -----"' .. ---.... -... 1 --~-, ·-;:. ..)! ~--~ .... ---+--'. ························~ . --=--=-'= ~ : ~y-'~) ---.---~ . .. --1' • -: . --•Q1-• l ----1 -.• ·-.. -...., --. --"' .... • J .. --• ··f-...: ... - ·-.. -• 1---.• --f--: -'-•- • --{ ---• . -· ---1·--·--- 1 . -· .. ----·--. ---- ·--. -. ----. -.. ---. -· ------;...,. -:-- I ' 1'1 • - -,--;-r :· ~-, • -... ., - . ~... . • ·----....... _1: .... -., ---. -.. .; ---·h ~ -·--· .. _, -· 1-· .. ··-. -·-..... -'--~ i ·- ~· -·--- ..... .. -..... ~-. . -' .l ~ • -t •• • ;. J ....: -_;_--~~-" .. .:..., ...... -.- I · • 1 1 ..... -; . ' -• · ; j • , • • I I ~ j l~-·-~-· ....... -..... ---+-.......... ; .L-' .:........; , ___ J • .,....:j~-l-,.. " " • ' . ....! . ~ •. __,.., ......... ~~ • • 'f ........ -~ -~ -· . ..; ... I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE '1' liX. t£.\hl A.. 'FE& ~\\ffi_ RIVER MILE 0 1 10,000 I 20,000 30,000 I '40,000 I 50,000 60,000 Di8CHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 I I I I I I I I I I I ..J w > ~ 3&6- < w (f.) z < ~3ttr\- w > 0 m < 1-~~2: w w LL. .. z 0 i= St(J- < > w ..J w 0 ·--~-.---­ ---1---. -~-- --+.:.~.:- ---~ J •. -:·-: -__ .....,.. __ -~-~- --· .,. ..... ···...-·r·--·---·..!----- ·--4-----· ----~-----· I ---..1--------~ ---·. - ' ---------. --r--______ .., ----'T •• --. -- _--__ -j -----i---.----··:.: -~ :_· ~ --~~~-fs&\\~~ \4\_ .. --·--~ --.··~ .....--;-~---·---r-'-:-----t-· -~--; ---·-1-=~-=-------...!~-~-. ~-:__--.. --~-_ _; .. ...:.... "7.·-~~--.·---t -· ------·-. --. .... .. .: -... -·---. -· -----·------.. ·--t· ---·-----.----. ·-~-· . ~--·-~ ..... ,; _ _.!.._~--~ _._ __ -.--; ...... ~-----t-·--! ---.... ---! ---··.! ----; ---------··--·t--·---· -·----·-- -.-----1----___ ____J. ---·· -------+-------- _ _j,_ -·-----. -_ __._------1. --··--:; ----· -·--·-t-·--·----.----1---· ' -·-.. j .• -·---•.•. -· :----· ··---------t-------.----------··1 ... ---1··-. -· J---·-·------·-· -··--;----·t·-----. ------ ~--. -... ..... .... , .. -: -:·. ---i---o ~- -----,.--· "i . -·----' I 4 . -· -----1 l • --·. '1 .. _____ ) I ------1 ---! --· --·· ........ ' , ...... _ r· ·-.• ·1' --. . -. -~ . -1 -... . . ~ -- ----------.-·--·---.. ··--..--·-.. ..----· .. -·-·-__ .. +-· _ .. __ _ ·---~--- . ~ . . J -· I•'"" ___ _ ... -~ ---~-··- --------·-· -------------------4-. . .! I -· ---J --.--j- . ·• I . ----.1. --.·T .. ---... ~ ' - • ·t . . --.: . ·-•.• 1 --.. ' -. ·- t • -· --~-1--• ·------~ . -·-·------t ---·---r--I -.---~---- 1 + ·:· --- 1 . ·-==-= ~ ...... __ -_-__ -,·.--+-._---: J --=-= ~ .. I --.. -~------·-- I .. ----.. 1 .. - --· ------.----r--·-··-----t···-· --· -· ~ ·--. . -· t· --·--..., --. ----. ' ;,,,_.:.._ 0 I v . . -... ·-; -J~ ;----·-;-· r-·---·-··---. z· . .. --~ ! -.. -.. --, _,.__ - -.. --~ ~ -----4----... .. --~ . ---.. ! -. --· . -----=~-k?C -· ,-----. ------·-· -' -------r----~ ~---... .. i · _________ _.., _____ -------·--------. ~--. -------·-r-.-·---·---··--· . -~-2 .J. . ..... ·--·--· .. ------ i --...L,. j ~ --: -~~ ----· ;----.... -------.----~-------1 ---.: -·-----•• ..__J __ _; ---r--·-·-·----...... J- -----·--: . . -------~ --. -. z ---...... --1 -! -.. ---. ---------t-·--!--. -• ----J +---~~------r-----·,-·------r· :. __ -·------ ·• ··--- ... ~ .. - J ---I 1 ' .. --1 .. .. --.,.._ ... ~ ~----·... i . -:: ~. =:L --~-~-:-~ ~-= -=-:...:.. -----~ ~y)( .. ~---= .:. -~=--~ : ==---=.:.. . ·• • • --. • --I ... ..;. ..... -· . - ------.--· ,. . ·-:: . -~ - I 1 -- ------+ -·----.• -· 4•. ·-----·-...... --..,. -----· ' -·--• 1" .• --· --I ·---". 1 --... ... -....:--------------. • f • ---··· l ... . . I ..... .. . -"' -= ~~~! :.= • -~--.. ---. ------~ . --·-l -.• -----·~,----__ -_.+-~---~:-~-~-~------~r~-~-·~-----·-t~·-------·-r·· ______ -_j~--··--~----~i--------~·--_·_·, __ -_._-1 _____ ._-_,_~ ~----- 1 / 1 . --~ ------i . ~ -: --. i --r· -~ -·-. l ---.. .. -... . 1 ~ . . ----•i ••• -----• " --. --------.. . . ~ • -..... .! .. -.. -l .. i ~-... -.-.i --------t --..-.., -' ......... ' _ __;_-... 1 -J --• ··~-+-·-·· - : :_: ·V: .! ' .. I•·. -~ -·-~ .. ~ --·-- • - -....!.---------·:··-· I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE ~-9 RIVER MILE I 10,000 ' 20,000 30,000 I "40,000 I 50,000 60,000 DISCHARGE. CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 1 ,. I I I I I I I I I I I I I .:.J w > .-1\\2.- 1"10- ~ 4GCO- c UJ 0 z < UJ ~""· ~~- w > 0 m C( ~ .onJ'\- w w u. .. z 0 t= ~oz.- < > w _, w 0 ----1 -----1 ----• • --• ~ · -• -r-t='lJ\1 --~ ------. I ! -r·-·-·-· ..... --·---·· :._~:._-~ :-·-: __ ----~-! --4 . ~---1 ----t-----·---t:----+--....,...--!:!---·--" ---+ ~ -~ .l... . --·--.:... -· ---·---~----f----:---+----·-----:.·-. --------+ . . • . • i .:._ ! -' .!. \5 I ' - ' • • • --• •-··--· ---·-·..,....+-----..__ _ _...., ... - ---~-! -,---.. ,. -..f -----'! ·:-. '! --. ~ • . ~ . -! ' . --~-;-.., ··-· -~~: ···--.~:--~.-~-+----·---.r•··--------·-: -~ .. -·'-t--.~--~ . ; --:~~ -. ---=-=--• 1 .. -·-'--:::-.::.=-::-;.=--; ' ! ~ ---"'1 -; ·; • •• ~ --•• I ·----;-----. -----·t-·--·-r-· ---~ -·--·· ----; -----· ---••. --1-••• -·--; ------------+,----··· '·-... ~ -----1··---·------... ---·-·-t--·-1 --i·-----+----4-------1 • -i • - -------! ---·--f-·-. -·-4----------·-..,. ----• ----' I .1. . _ ••• J . ---·-i --------+ . -----·----· --------~~·----. + . I [ ; ' ___ _. ______ 4-------~-----+-----~---~-------------t------.-----~-------·----- i ----t· . ------:-------t -'---... ----·1 :: ~--=.:-~=;-=---------------·-·---~ --. ---' .. -------__ , -·--·· ----·. -·-·---------,-----~ ----- ---~-~ . . - ---.• j ---1-..C-..-.. -f ---. ---. ----·-x- ---; ----. -----~ -·-t----------_ .. -------.-----·-----~ --· ---, --.... } I -· --· -! --. ; . + • 1 .. ' • . ---:-... ---- . ' = =-~ 'i : ~ ---i . -1 -- -' - , - =-:-J __ _ --· ~-........ ...... --~ j - ---.. -.. -·--. ----+----- J. -·--·--·--~----·--·-----~----­... -·-·------·· ----------· ---- i .,. ·-- -·-..1. ·-------.__,----- - -j ____ ···- ....... . -· j ---·---. . .. ' ----·---... . . --------···----. --T----·-----~-·---I I ""' -··----·-----,-.. .. ---- ----·-l -_...;__ i-----. ---- -! ... -1 ----.... \ ---- ·j ----· ------: ... ~ ... . .:-~---r .--:._· . - . -.-.. ., -. -- . --+---~----'---+-------------+-----.-. --. -·-,_ .... : .--··--~ -· ---~-~---_ ... -:------_.._ ___ ., -- ~-------------· ·-·-- . -...... j .. ··-· -j -.. ----~ I --·· -~-~ -------,----·--______ , ... -- I ' ' i • '' • -'1-~·--.. -·----.---.... --__ ....,. ... ~-·-t =---· -----1----· .• .J--' ·---r-------i-...... -· ··-.. .J----• ---.. '-•• ----j-·: ~~-==..: -~=r-~·:· ~=t~-~ ::: -~ -~ ~~-~ : i : ~ .. ·-_-_-___ ___;t'-----+---_-._-_-Jr-. -----= ~:~~---= .: .. -= .. ·-~; . -.. --~~ ·t ·--~-~ ~ .. - -.., .. -.. __ __!._ ----·--... -... ---• 4 .... "' I • ---• • • • • .....! • • --• • -~ •.i • ··--1 .... i .. ·---... -·-··-v..::::-__ .,. -_·-.. -=.--. j' -.. -·-·~·-·;-. ·---·-..-----· -· --. ·-~ --... ·---~ ____ ... ---.. 1 oo,. • ••· ~-• • • ,. • "' • "' ~ - - 0 ·~ . -·--~. -··--v-----r----~ --··· ··t-- -.. ---1 ---· ---l ---· ·----· --; -----.. --· --i ·-;z. f------1---------.....:.....,... __ _ -· ----~ ·--"---~---·· ·--·-·-··+ ----· -- -'1 - ' , .. ---· '. -----. ' -... -- --·--~ .. -- : . /-j ~~ ·: ---~ ~-· -=--== ~~--::--~ ~--~: --~ -~ . -~----_ ~ ~~~ ~~ ~p) . -.. ., --/ -~ --! -·---·-__ -_--_· -_· _;~v~-·~;/~_---:-· -~~i+-i __ -......,...---+....,..··_ ··_--__ -.., ... ~-_-_r-·--_-t,...--=--=_-_ ..... ..:.. ___ ·-_· -----r-------· -~·:---. __ --;----J' ~ : --· 'l --·--4. -----·-.. --~ • :..-=-~-·~ . ---. . . i ---~.;-·:-~ -: .. -1--,· ~-~----•. 1 • ----·· -• • ; --~ ~ .. -· .... " ·~-·..; i .... -... -.-~----·~ -·--.. ....., -· ..;,.__... ' -, '"! _ ....... ..,. 1.-•• j'"'" ........ --····--··--'·-....................... . . __ ./_ ~ -!-. ----. .; -.. - l . l. __ ;t~- -... ·-., .... -·--..., ~ ---~ ----· -:--... -, -: ~ . 1.; . ..... .: • ~ ·~ j --·-- !. .. -i :. ~ ~ .t·~·~=-:~ --.. ~ ~- 1---·-·--r--. ·---·-r---- . ----r--·-· ·--; T"' ... -:---- ··--...;-!----· ·~-..:-·--- • t ; . --,----.-·---:-·--~ -·-..._ __ ..,.-. --:..... ~-. .,.r: ~- . ·-·· • ~ -· r-.• ,----J-1 - • · : i : • • I -.,. t ~ i·-, .... -1-·~ ·-~---........ - I ..1. ' ' • _1 _l ' t ,J -..!.....!..~ :."f .; _..; .!. i ; J 1 • ....! J.....; .. ,_! ..1 , ... +..: . ..;.. ...... " • • I ._!_ • I i -! ...... • I T -·-· ....... J ........ 1 --....- l 10,000 ' 20 8 000 SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE L R~-\0."'2.. RIVER MILE I '4(),000 \ OC:., B t I ~o.ooo 60,000 DISCHARGE. CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 I I I I I I I I I ..J w > ~. ~\"'\- < w (f) z < ~ 4\2- w > 0 m < ~ ~lO- w w u. • z 0 ~ 4~tt­ c: > w ..J w 0 . . . --· - -"l .. - . --. --,·--. 1 ....= -=~=-... .= . .:-...:..l. --~~ -1~1~\' _,. --·------. ---. 1 "t ·-··----• --·-.--.....t -; -:---~-.. ----~------·r--:-·--r--~~--·-r----• . -... ----:-t .;..-..:-. _. __ !_ ·-----·---: . • ---·-'·--• ---------~ • -. . • I l --,! ~ H.o. --~--. -"""'" --·-~ ~ -·--:--··-~-.;-,----t-.-·-+-·-------~ -··'·-. -··;-·-.. -. - - : .. --· -r" _; ., ·---· --..-!. . : ---.; ·: . -..-r------.-. -l-· ~ _. ~-r----"T ---; . 1. _. -----........ ~ ·-~ = -= "l --~ :.·:= -=-= .. =:-----· _. __ -+ -··-·--~-------....-+- ----;------·! ---··--· ~----------t--------.. J -----r---·------'·---·--r---------+-·-· --·----~ !••-• -· ----• •• -t------·-·· ::-·,----I -------···-··------~-·--·--------r----.. --.. , I .. ··-···: • --··-.. -. ----• 't-. -·· ---;-----..... -----r-----. ·-l t-_.. '"'----------------··--,... · __ .J·-:. == = ~~ l . -------~ -:...-=-~--=.:-= -··-. -------· ··--·--j ---··-t-t·-.. --.1 .. -----. --·-----··---;---··--·---. -----·: ---.. - - - -·----••1 --· • --...... --... ----_.. ---------,. -------.. • --~ . -.. -·--~ . ·-·---·---·--------------:-----·-----·- ------, --• --••• ---... ---·--• -· --;-• • --------------------.. -.L -• -• • I • ' ---"!---- . --j.. 1----·i-··-------~ -----------j-. ·--- ----, . -. ·- I --· ~ ... ----. ····-t· • --1 -·-l I • 1 . ~ .. --. . . . ••• -• ---· -------• .,! _____ - .. -. -·. -------· --r----·· : . -: :-:; =--=~~-r~-~-~ =:t-:--: __ _. • . ·-: -----• ~ -. ---L . .. --..... ----.. --·-·-- ·------'i ..... ,-·-·-·· . --·-- • ---"1 •• -- "' -_.. • t' ----- I ----, •.• ; i-• -. '1"-¥'"-·-· .. ·t·---. ----. . . .. ~ -.. ----~ ---·- ---·----·"fr--------·--;----~ ·-· ----t-, ----~- ---i ' . 1 -.. ;------., ---.,----aoo •-""" • • ------·--··-_______ _2 .• -----........ .J ---~ .. ____ j ----j-~~-.. ~ ....... -.. I ---. : . ---.I ... .. . ----··-_!_ ______ _ I ----.., . -~-j ______ ; _____ __ . ... ,. ... --.---·-... .. ---; • -· --· •• J -• -• I ---·~!. ----.. -:. ~ ~ T~ ~ .. :.:: :·... . . -:---_-=-_ ,_-_- . . .. -·- ···--· ... --·· - ·--1----·- ----i --·-----·-1----. -~ " .. -·-- --T"·i • ---. • ·--+ - . ·-. . ·--i ·---. r . -. -4 -• ·-• ... r--.. ---------i -·-· ·- ~ --·-·--·--·-···-r· .. ·-..... --.. -.. ._-...... ..., ... ---~ • j .... ·-*" ~ • I . . +--_;_~----r------~- ·<p<-• -·j--. . - - : --= -_] •• --1 ··;--·----. 1 __ J •• -• -· ' .. ., . 1 -. -... -- -.J. .. -...... -...... -.. • ••. ---.. J •. -• ----. ; .• / • -·• -I • -..... . -·--: ~ 1 ,. __ . I ·• • .. j_ .. ; . ~ . ----- -=----J~ -: ----= ~=~-= .:-~=.:. _-v~ . --··--~ ----· . -----=., __ : __ --. -. -.-. . ---·tz--. .. . -: -- ' _l ·-• -~ -• ., • • -••• -• --·· 1 • 1 --··· -.----. -_ -_+_-. ---~--=------~-~-----~-:-=+---=-=-=---=---~--=-~-------t-F--------:;~Jp:~:;....~--------_--r_-___ -_-_ -:-_-= :·-_-__ -_-_-_·-_-,-- • ~ • .. - -.. ----------..!.---:,.?"" ---"""'-...;; ----' •. -. ---·-... -····· ---. ·---. . --~ ""/·-· ·--··-+ ------·· ···-· l .:--:.~; .. -. :··.~ ~-·.:. ·~-:-_-.:--:_-~-=-.:=::-..: :·-=:.: : :~ .-i.:-DB~K:P ... --. ; . ··---~·-· ~ --. ·--/V-"i.----.. --~ . -·-............ ' . - . _, -. --·--·--~ ·i··--.--~ . L.-··""'--+------r--·-·-·-1·~-.;... ----. .J. --• 1 •• -- . -_ ----........ -.-.. -_r-t-....... -.--.-v::-... --. -1---------.... _, --'---... --~ ~ . ·----·t ~ -.. ! .. z! . . ~?<. -... --i--~-~ • -• l-·-.. i. . . -~ . ~~"' ~-·-·-·... . .. -. ·--~ _..:_-t ~-.. . --;· --·-·· , - --... 1 , .. 11 ... .. _., ' 'II .-4 .. • .... -r-·-.J ' -. ""' ...... ... • --• ~ ... ... ... .. -· -·'"; '! • -· • .... .• -• •. -__ ,_--• ---l '"T..., • -.. .; J - -..,. • ~-.. - -__ .... -· J SUSITNA HYDROELECTRIC PROJECT ...... ------· ..... -. -... --· l 10,000 ' ... t 20,000 I STAGE DISCHARGE CURVE LR~-\0.~ RIVER MILE \0 to) 34!\ 30,000 I '40,000 I 50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 I 1- I I I I I I I I .I l:f! P.aJ I ' ' ...J w > ~ "\ltJJ- < w U) z < w 4\dr-~ w > 0 m < f-w !!,' u. .. z 412.- 0 r=~o- < > w _, w 0 . ---'--:·-·----+ .i. -~ .. ------~ - ' I ---+ .;..-~l-....- -----J ~-: ----···r· -·--· : .. ___,.=~:_: ·, . ..= ·=-=--i --~-=J~t\}~1\ r=t- ==--=-= ~ .;;. ~-" -...------!+-,-~ .----r .. ! -_: = t-=-. --=; ~-. .: =--~~ = ~-~-·, ---J ·--~ !. -· ---• ----1-·~--. _______ ..____,. __ -·---·"---~-.... ~. -· ---· ·------_.....__,..-;-1-? . ~ -r·~··-·-·-1-"----. '! -:· . --· ~ ---• .., . '1 ---~--~ -~ -----! ... ----:-, "'';~ 1. _-_:-_--.:~I_-~-.. -· ~-=-=-.-1 -~ -"2 ::~-:· -~~ ~ • ---~ --------·+-··--·------··-------i . ' - ~----. ~ =~~--:=-=---= ~-~ -------. --------·-r----_ ~--= -~-~~ . ·j ---~ -----·---4·-----.--~---·-i ----~·t-----. ----· .. ,ti --------~~;------~r·-··--·----+----~------_-_·!~------r-----~-----~-------,_---~-------,-----.----.----- --~-. ____ , ________ t-------;-----!------;------·! --1 -.. . ---i-.. ------... -----;,-------....--... -. ----·---·-· -----t ,... ----• -----•• ..! •.• ----. ~ --..l --•• -----, • --! ----i ---j . ------.:. . ---. ·---·--·-'!· -----------;-----·--· ... ----------~. ... -1 . . --~ -.. . ------. -·----' ·--·-·· ~-------.... _....,.. ----· . ·--~---· ----·-----· -~-... --~--------t--. ·-·---·-· --·----------·--·-l ~ -~ l ... -~ . - . - . - .. ~ .. --,---; ··-·-1-·-.. -·--1------.. ·-----.....!..--.. ---~...:....-J------..._, ______ -+- I __ .... ---t ---· ! --·-, ·--..... -····-·----' .. ------..... ---.. ·---. -..,..----... --·-·-.. . . . .. ., ·-.. ---I . -·-t --; .. 1 • ---1 ---.. l. I .. -• I ... ~ -i 1 .l . ____ J , ' ' :-··---- 1--· _·_l~· ---t ----'-·----· -. -I : - -7 . ---- .... ..;. . ~ -.. ---- ---+ ------- _J,.-.... ,-- t -------... - .. ~ .. ---· -.. . ·~ -- --·r-- . __ J • -·- . - -·-- ----- -... _. _ _......,. .... I .. ~ - -J ... ..... _--t. .. --- I -_ ___,. ----· + ! . ---~ . -·· ., .. ---· . ; ...... -.. 1 • .. .. -.. -., -. . , -.---- , .. -- -. -~r'- -----~---~-----~--------~~--~---,-----~------t--·----·-·-----1 J J. ~ • ..: .......... -· :: : .·~ :-~ __ -___ ~ 1'. --·-·= .: ~-~ . -· ~: ~: _ _.J ~-~-_:-~ .. --· ·-.. -- ,.. ----1 ·---•-----·-··-;-T·---= ·~---• ;:·~: • l -·•-: ··-., - . .~ . -------·-. ----·. --·· J --· ··--·-.. ···~·-·--... ----· ... ··-·· .. --···· .. """ .. ' ..: ---.. .. : -~-= ~~ :-: _ ~-= ~-~-:~·--::· r-~-------~ :~::.. -:.~:· --~~~s~ P..Ntp --• 1 .•••. ~---·---_ _,___ --- --~v------7,___ I . -.• -_ ~ ~ • -=-=-.. ,. .. _ l • "' • 1 ....... -.... ,. . "":" ----:-t ... ~---.... 4 • ~ --L-......--.-: ~ ----.. i __ ............ -r-~ .... . .., .. -.... ! .. ..; -~-~.--t ~ - -. i ~ ~ ... , ..... --.. I ~ . / ... ~~ _j-.. . • ;. .. -, ... -----L -.,. ...... ., .. .. .... .. .. / j·· i . -.., ........ . ' r ... ""'"t ~· ~. .. _,.<!-<I ~ ~ ·-• • ~ ~ ,. # i -~ : • l ., -l .... ' . . • '1 ·-·-. .. '"" -~ ~-: .... .._..., . . -· . i . . -·- • • -• I ----•· -· " . -1 . -·-. "" --....... ....a.-• - •. ---_j_ -·-: ··- . ·-· ;·4-·------~---~t· -·r-. ..... , -- . -·: . -. . . T t .. • ~ ! ...1 ~ "!' ... • .. •• •• .. .. ~---~ 7 ""'··-i .... ...;~---· ----4•--'t••~ , I I , • I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LR..~-\\ RIVER MILE \ D~. (o~ t 10,000 20,000 30,000 I '40,000 ' 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND ._--------~--~~~~~~~----~~~~~~------------------------~~ HARZA EBASCO JOINT VENTURE OCT 1983 I ' j -II . ~ ' ' l.tl I ,i: i.'.·. .. . I . I 11 ~ --r---, -~-··-·----,__-_-------·--···-f·-:~ . .:--~ _-. ..:~.~-~t\\&TI \~. ---.---·-t ---·+ -· -------... .i __ ------... -----~-. ... ...J. ...! ' ! ---~---:.. - -• .!.-~ • -·-· -·-· ... _ ~~--;------------·-__,1··--... ~ .. -.. ---,. -: • -.. -----+. ..... ~-~ ... -·~--,.-1· .L--T--~1-~·---~ __ ,._.; ... ~ ... -·----::•• -. . . ' . ~ --~---··---·-~-i·-=~---, ~ ~-·-··~·i-'"--------~--~-· -!·--...... --j-· ., --·-+----·--~ --~---_____ ..; ____ ..:__ ------l-------1----·--: .. - .. , .. ~ ..J w > 432.- ~ ~£.<0- < w C/) z < ~ Ailk- w > 0 co <( 1-~~­ w w u.. • z 0 i= AalL- < > w _, w I ·-j -:·---''l · .. --: .: ------------------+ .. --·-· -· --~-·--·-··-·-·-t--·-I 'l' ... ____ J ----"----t ·----· ---·t-·--------··--r -·-·-·-. ---.... . -----'~---+----~----~--~-----r---------;-----r----_T ~-.-.. -.----~~-------;----. ···----2-··------------··-t~---·--+·-·---·----.-1 • __ .. ._.!--··-----·--! ..... ----t---"' -.--.;.____ ----:---·---------~ ~ ,._ r--_____ .; ·--•. ·~-•. ! .... ---------1 ---·-·-------; ---·----1 . . _ _.__ __ ~ --. -· ----· ~ . ---··--·---;-----·-+-·---_. __ ---·-·------------.. --··------_,. --··-.........---____ ,. .. :_::=~1~.: -~-~ ~~~-~ ~ ~ :.=:= -~-~==+==-=·=~:~-=~=-· -=~~~: ~-: -.... _ ___ .,_,~ ____ _ --·-1 .. -••• ----•j . ·--. ______ .. __ .- ·---. 1 . .... -.. --~; .. ~ .... -~ - -i ... • -• . . -. • 1 , _____ .j .. --·· .. •1 .. l . . ... ---• ..1 ---• - ---.J --' "": --.._ ... .. -·+ -... ---j -· .•. ---1 . ------, .. ~--· . ...... -· 1 • -... ·---1-~·-·~-.: 1 ..... . i --. -. " -I .. ' -. - 1 -• - -. 1 ----·-• ---t - _____ !,. ___________ .; • t ...... . • . .... --I'" ••.. "'!------------------+--~---. --= L· . -. - !--· ..... ~--.... _ .. ·--··-···-.. -··--·: .......... ... : -- -··: ......... __ . --. ·--------·-.... ... ""' --... . . -_ .. _--_~ .... · ----T-·-:-:; ____ -----. ------·-~ y: -......... .!-·----· -·---·-. --~·-.-------~--/·=--~ : =::.:-~--. --~--_ ::.:.. ~~-=-~:-=~.:~ ~ -~=~-~ ~~~= / .. ---~ -i I . ·-. -~ . ! .. -. 2 .......... __ ......... - I = =-= : l: .: =..: :: : = =T=-:: . =-zv= : :..:.: j . -· ..• -~ -• --• --. t ---• ----. -. . ------'l .• ------...... ··---'!-----···· ---·-··--·-_-_·-+ __ _j --""T-··- -. -1--·---V.·-·---,-··-.. . --i;r· -. -. --~ ---.. . ---; -... --. v ..... -·--·---4 -· --• • -. --• • ---• • -1\• -:-. . -. • T • ---- I • • --..... ~ -·-... . --. ---. A' . -~ . -.----·· .• -• .:. •. ---.---j' : ~ ~ - . -... ·--·-• -· ---.. - --·· , -• --· I • ·--·· • • ·--·:-·----.... ·---·t --------. . . .. . .. -" . -.. -. . ---. -, - =-:-1 ·-.. · . ---. ~ .. --;/ -~ ~ .. -;--· -· ·--· ---,--·.-=-= ~ ] i z= -. -·-··-· -·----·---· -·--~-------... -~:=: j: ·= : : ~-: ·:::_j( 1: -:-:--=~=-·:-::..--:---=~=:-:.~ ~~=:-:.: ·---j •. -• -+···--· • _,._, :/(' •• I ·--J --;··· -· --~ "" ,.. -~ • 1 · r. : • ·---z· --... .. . ... . . . . .,. . ~ " .., -./. . i-- . -~ ! ... -~ + • • • I ·-·-· ·• • - -• .1 .... , -• ---.. ~ ·---· --. ··--~ -------. ·-'1 .. ~ .. -.J...---,--.-·-...... --J __ ._...,. -~ ... ·-·""" . • ~ .; . ..:.~-..:....t ~.__, -,.-.-.· ~ •• -.·-.-.-••• -•• -.~·.·II .·.·.-.-•••• ,.·-.--.·.·.· . ---··-+ -:.:.:...»- -. . T -. . . -~--.. . . -- - -.. ., .. -· . ""' ... --... ~ .. . -. -l - . . --•. -. --, -~ .• • ... ... . .f ~ -...4 ... • ·-- - -'--··-. I . • •• I .... -- .. --,.. - j --·..;.. • • -•• J ___ -... . . . . ... • ~ --1 ... ~-• "' -...... -· --·-···-. -·-_._ ___ _ ' -_...;--· . -· ·-. . -• r---• - SUSITNA HYDRC>ELECTRIC PROJECT STAGE DISCHARGE CURVE L~-\'2 • ! • ! ; ~ • -i . ~ ..t.,i .J_., :· ~ -j-j •• J. l I • :_ RIVER MILE lOCO.+\ I • • •-----;" ' 1 .., j-.,_ -~ . ... ~<4-r-~ ""' ... •. ~ 1 •. .,. ~16~-------~---·-··-···l-·~···--.-.--·-·-,----~,------~,---- 0 10,000 20,000 30,000 '140,000 50,000 DfSCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 i. / t . . : .. -~ ...... . '! ·j . . .I .. 'f 1 \ • .... ·1 ~ _, ~] ,J .;! - Y:i )I I I I ~- 1 Jj ~ ' I . J£ ~ Jl ·~ N1 -' w > ~~- <( w UJ z ~43~ ::E w > 0 en <( .... A~b­ U-' w u. .. z 0 ;:::~~- < > w _, w 43l..- 0 .. : .. : : : :.:: : j ____ ... :. : _ ~+~:=, __ _ ::·~--: :~~~~ j : ~ ~: ;_ ~: -~ ~l ~mll)ll 19 -.. ·-· ... "'-~ .,. "' ... .. ---..... ----J . -------r----------+-------------·-· '"' • ~ "' • ,.. --• T •,. ...,. •~ :. - -~ -• -"_,. • • "' -~ -~ ..,_ .-• " "' .., ~-= ·::. . -· . .. . . . . . ------·-··--·-... •·.-·t---. ; ., -·-··----r·----....... ·±-.. -.. . .... ~-·~·-·· ··-~ ... --·~"'"·"---~----·-···· --·· •.• --; -. ----•• ' . -• ~ --------. ·-----• J ~ ·j . ' -"" -_.. of ... • ' .. .... .. --"' • .... • -'-__ .,._ ~ - --.. • ... --<!; .. ... ""' -1.-j --~----·-· .. ·-:·~~: :~. ~-= ~-.1 . 1 . ...~-·! .. .. . -. -~ -.. -. • -.. . . i _ __._ __ -+-----j------t···-···-.. ------r-----t -----.,:----. ·--·. . .. .. .. ---~ · •·••• • • • --r•• ·· •• • ~-~ ~ -:· ~·--·: • • • • "'" • ' y· 1 . ---l -· ••. • ~ ... .. .. .. ... . . ..... -.. .... ~· -..... ,.,.--~ ~ ... j .. " "' .. ---- : ~ :·: -= . : . - . . . : --: ~-~ -~~= ~ ~~ : ~-~-~ : -=·~~-L--: ·1 . ... .. ... ""• . .. . 1 -.. -· . -~...:.:-·-J . -~----: .:~ -~-= -~ _:_~_ .:..:_:__·_ ---·----=-. ·-.. -·· ···----=--+----·· ... : I . . . -. ' . -. . . . : · ~ -~ --~ V-~ : . · · ~ -. · · -· .:.·:·:· ~-~-::.·/ ~ . .. ' . . . . - l . . . 1 . l • .. .. ····t······ ';j -.. "' • i .. . ; ... ·-t --.. .. ... • • ... L .. --·-·-·---·1~-----------t-----·--:--~ : ·-_ -_ ;-v--r-. -.. · .. -.. -~:-:-:------~ 7--: -.--.---+-------···----- / ~-....... •· . . i -... .. ... : : -_ ·: • r ·--:----~ ~.-: •• = • • • , . ' • • . '"'ol i ·"">••-1 ..,,._ ..................... ~·-.. ·~~--'II·''" ----~---~----~--~r----- ........ _"' ~ . "'~ ;/ .. • • 8 .. • .. • --" -.. ... .. --+ .. .. .. . ·. . ~ ~ . . . . -. -·. ~ -·· -. .. ... .... .. . . -I . .. -·• • . ·l.·· • . • . . . • • • • . . • -. --1, • . ~-----+ -----+·-----:--+-----·-· --···------· . -. ~ . ~ ·zi· . V. : ... ~.~ : ~-·: ~--~-~:--~ _: :_ : ~-•. • .. "'I .. ... ~· ... .. .. • ~.. ~ ~ ... : . .. l - -.. ----·-----~-.. ... ·t . .. ... .. ' . ... " "' , . .. . .. ... .. . -·- .. , .. .. "' ~ . .. ·•··-· ···--. ~ . t -. . -••.• -................... -1 f . ..., .... --... ---··--·-·~---·---• ! -·-i .. i ~. ·j::: .... f .,. i . .. ~-. -. -1 ~ .. :----· -!·--. -. . -..... _ -. . -· • --..•. -~· .. • -• - . • 1 . . . . l •· . ' • .. 1 / • • 7 -. • • . • --~ • . -] . -- . • 1 • • • • • . • . . • • ' . • ! • • • . I r--------~~--~----+---~----+---------,---------~---------- ·/ ·i -. ·---·-····••·• ~-., .. 1 -,... .,. .. ~.. -~ !!! .. • 1 ~.... .. .... " .. • ~ ~ . ,.. .. ... .. • ~ of ·-: .. • • • .. ·. = ~ l >-: ' . . : .. : : : . -~ -: ·j· .. . . ~ . : 1 ~ ---..--.-·---.-.,----...---· !-------------·-···--·~----·-. . ---·- 11 -----· . ---. --• ---t • • • • • I • • 4 ; ... _... -~ ............... J .....• -.. · -. .. . . ..... "'" ~ . l ' !, • "' -• t • .. • -. ,. r ~ • ,. ,. .f .. . ' :/; • • .. ,0. ! ... r+ --...... ---~--r--·----~---· ....... ·+--·-. . . t . • • . ,.. ... .. 1 • .. ... ... : . 1 • . . - ' SUSITNA HYDRC)ELECTRlC PROJECT -. . 1 . . . • . • 4 .... • . • . . • . • I ~ "" ... ·- STAGE DISCHARGE CURVE ... ~ ... "'i .. •t . .. ' .. • 1 • 'I' • .... ...... ..,_ .J.. " .... __ .._ -+-----+---~-... -.. ..,.....;..-;------.---~ ·~'11+· .. -...... ~ ...... _,.,. ..... I 'I + -... ·-.... ~ ... • • t ~ i . ~ t ~ + 1 "' T· ~M ~ ...- 1 ... .. .. ~ ..... I< 1 "' I I 10,000 20,00(: 30,000 RIVER MILE I '40,000 \I D. ~ I !)0,000 DISCHARGE. CUBIC FEET PER ~~ECOND 60,000 --~~~--~--~~--~~~----~---~--~~--~~~-------------~~~------------~ 1-IARZA EBASCO JOINT VENT'URE 1983 I -~-~. ~ ~ : ~ : ~-: : . -_ ~ . ~ 1 -~ . . . .-. :. = ~ ~ ~.: ··=-~--=. ~-: J . :· -~ .. : • • • 4 • . • • • ' J . . .. • ''1 -·· ..... ·-. . f --.. . ' . t u1 · ~~~ r-~ ·: ~ ~: ::: ~l: :-~=--: -=-~ r::~-~ -~ .. -~ 1 ~ :~-=-~ · -~r~: ~ > . l' . . . - . . -.. . . 1 • -"1-· .. -• . • . . • 1 • • • :::1 A4'l - : . . . . -1 . . . --... ---. .... . . --- ~ :::.~~ :~l! <:'·.:1i' . .:_j·::t·;::>::: ~::·::_ C/) ·--· . ·-------...,..-----------r--· ~----·~---~-+----:·----<··-... 1· ............ --·-... -·--~ .... --.. ,.. .. __ , .. ·-----· ··-... z . . . . -. . . . . . . . . . .. . . . . --·-., .. -·-. . . . . . . . . +. . -· . I • . I -. . . . -·. . . . ~ . -·-. . . . -: . . -<C .• 1 .. --··~ ··--. ~-· ·--··-·-· ···--;···· w 44'b -. ~ .. . .. ~ ' 0 -_ . ----:-:~-, ~-.. ~ ---:·· ~... . .. -~ . -· . t -· . . . ~ :::; : :tl :. ::; : -r.-~:3: _:< :~::: ~_1_-~ ~_{_: :~ :-~-~:i ·- m I l ·-: --~ .~ .. -· .. ·---~ J·· . ~-·· . < 44 . ; -. . ~ I . : . ~ ; I -~ • : ~ ~ : ~ : l._~ _= :_. _.: _· :_~ . ...._..· ,:.__. _·_ -_· --..--t----- 1-.. ··'-__ .. j ••••.•• j ..••• ~ • 1 • w -f . -i -.. .. . . -~-j ~ . . ~ -: : . il W -I . ~ . . . l . -.. LL. . . -+ . ·-t----------+---·--....... ··-z ---~-:-~-~--;---.. --: -_ -~ 11~·~ ·-~-~:~ J :·:--~T---: .J~ ~:~ .: . Ql-A'~ __ ·_· ---#----'--·-·_-,_· _·_. . . ... i . . + • • •. •. • •. ; . ~ -w-~ ::· .: · -1._· :·~ :J·-~:~d-~~~L~--:t1 :..:_.:· ...J ~---'~ • -• . • -..••. r. --. ··-. ~ ... l • W . . .... -. .. -. • . : .j .. : . ~ : . I : . . * .. ... • -4 ~ " .., ... • .. ""'! -... ' .. t .. 1 ' .. -i -~ .. ~ ' 'T' "' SUSITNA HYDROELECTRlC PROJECT --·t·~-STAGE DISCHA~GE CURVE 0 • ~ .. .. -.... '1' ... .. " ... "' ... ..;. -.. ~ ..... ~ ...... ....... • + "' ... ~ .. .., • 'Ill . -~ : .. 'l' 1 •• i ..• ~ -.......-.-.......---·-' __ ___,...'"""""·...-. -+--..._....__,.....,... .... ···-... ~~ .... ! ' . "' : ... .... . "" . -i -~ .... ~ ·-·~ .:.1-·-1·~~4" ,. • t ~ J' ·~ -"t" ""'!' I • ~ 1 • • .. "'T "' ... .. ....... ~ .... I 10,000 1 20,000 30,000 RIVER MILE \ lQ ~S I '40,000 50,000 DISCHARGE. CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 60,000 I I I I . . ~.:.. tl1 ~- ·IJ ~y -J w "6%- > w ...1 45Co- c w t/) z < ~ 454- w > 0 m c( .... ~2:­ w w LL. .. z ~ ~- < > w -l w 0 .. ----1 • --;•t----. .. ·-· ····-· . -~·-., -·---t··.._ ..... _, ~.~-2' -----·--;--~-f. --, I • -t----------'--·-1·--.. ---, _, . -·-f ! ~--.-·-~ -·----~-t i ·-----+ ... ----.. ---4-T--. ~---·--~·-----·--I ... ·----i·-·----~ -----< . ; . · I , l t --· j-... _i ---i..-• ----·-----+--!_·----,r-------'-... ·--+-· -------,--•• ~ • -· ._ -••• ·- """!· I -~ 7~-,---••-t-.--".o..:.~ ••--I f '~ -·-· ~~~·~• _. • 1 • • f ' -~-------. -!...;-..._ t-· .. _ J. "'-----r-. ~------,.-----· -;-.. --·-r--·-----~ -----. I I --j • ··-r----t. -- I I I ·----!-------.. -··----1·----·---,------·-.. ., ...... -. -~ . . . -=:j----------i . --r-----. ·-------"! . ---·-· ----.---* ------·. .l --------· -----·· -··--j • • . .. .. 1 ·---i ---··--t ---. ··----~------· --·--4-----·-.. ----··-.... ·-1 -------IL-_-... -_--_4-_-_--_-_-+-~-----+------.~----;--------~------__ r-_-_~-----~r-_----;------7'-.·~~ . ----l-. ·--. ---· i , --· -----~·-... --1·, -------·-•-· ---I -·• · --~ · • ... ,... --..!---------~ ·-· ---.. -· _J---------· -··· ----· ---.. 1--... -..... _____ .,! • ~ ·-'--.. ~-----·-----·---. • . •. ---~ __ · ___ i_ ---·--.. ----.... ~ --·-·.--r-"'-----.-1 i ·-I • 1 ---·-~------·---•. --·--i----·--·-·-------···---------------! ·•· -----. -.---------·-·-- . ---l----~ ---~----------· •. . -·-j;----.. -.-4.---·--. -----1--·-----------------·4. ----.---_., .•.••. -l--__ J ___ --~----~-~--~ J-. .. --··· ~ . -· -- -----·--I • -~ =~~.1 . -_; :~ ~-~ ~: =----·-.: ::-r: ----~--=~-=-~~-----===· 1 ~ -~-~ ~- • ·---1 --. --• ·--{ -------· ------;-----------+ ----·--. ---... -----.. ---. .. 1 . ---------· J __ ., ..... ·---- -• • -·--------- ----· -i . ..,..-... ---... ~ . ! ' . ... . ... .,., ~"' . .. ~ - I -~ • ---•. -• ··--.! • -~-----·-L. ----· ·--· -J -4 ..... ~--,.·-"''t-~• -·-··~· .... -... -+----~~.. • -.. -! ~ --·;-···------~--·-. . -·-·-t ---• ----f ~ • t • . I •· I • ... -~ -----·. ~ . .. -·--... t -·--·• ·----.,---·-··--·- ~~----~·-----+------~----· . -··· .. ! . .. .. -· .. l ........ . ----i --·-- ---+-- . ---1 --...J. • .J -·---___ . _ _J ....• - --. --1-.. ···- -.. I -• ... --... ~--.. -. • ..... --··-.. .........._. __ ...., -.--. ·: .. .: ~: -:.·-F=-=~-== :.:-=---=~-=~~=-:. . ----~ l ______ ,_,. . -~ ' • • I -i I .., ... --:·-·l ........ · :.:-:·.:r~-~ .. ~-=--~~~-~~l-=~--=--t-=-=--=-=~-~ ---.~ .. .i · ··• · v---· : · · ==·i ~.:: ~--..... -.. !-. ---t-· ---· ---·-----... -·:·~-~---1 -~/ --=.·~. ~-. -~ __ ·iL-·-----·---+-----~~-----_-_·--+---------+~----------~-t-_-__ ·_··_·--~t·_·_· __ · __ -+-~~~~-7·~~~----r-·-__ -_-__ -~~~----- -~ ··-t -----· -j-·· -----• • -+-·· · · I /': ~-, --.. -----. 1 -.. -:--•.•. -i .. -----·---J·--·-. v---l -- .. -. """ . ' ... - i . .. .. ---~ : .: .=: = ·.-::.-:"-r-:-:--:-: ~-·_L -= ~ ..:..:: : ... _..:.·:!:.:.~-= :.:·..:...:;.:.:-=~--=·~.:--=~·-·-=-~-~~~~-·~..::~ ~-=-~--~ ----{--.. ---··1·. ·--------~--~::/.V-~-=~----~ -···. -!-. --·-,., ••• -• --·-""1 ----····-•• --·1-·:,.;..---_·-. -·--""1 --·. •• -·-i-.-. ··-•-'-·----~-------*·-±··---1-----·-T-·--. -'--:.I ----i ..,. __ . ___ .__.. ... --··-.·-----------.,..---.-··- .J • r·--1'"7 ·-··---ir------· -.,.._ -------; .. -.. . -::-: .. :.~ :. : : : ... ::-.:.: : :.:-/ v--·=J= ·-------+ ..... ·---..... ~ . - -------~ ..... ·-·- . .. _,._ -. ·-...---1----.;. ·-·-·· ·----------1----·--------•t ------· -·--L-J\..,!L-'L.J..I; -. - ----1---. --. -~-----·. -'Xj---·-r-·----"---. --A_~ c;:_.i_ h.'\t£: \'\. . * -·--·-t --~ ----· •• ....1..:7 --.... _ • ---~-··--·-· ----~ ' ---• ---•• • • • ---• -• -• • J .. -:·-·----_:-j_··-1 --• .:d._-~ . .6--~ ·-·: -~ -----!-'--------· : 4 ·----.••• 1 -~ ... . _, f'-' . : • . • I • -. ---.--i y· . ,.._ ... l 1 .... ·-------~----. ---.. --· ---• -. ~ --j .. -_ _; . --'1 ~.; ; --· . ... ... ....... . .. ---l --.. ·----· • • • i • • • c ____. --4· ' "' _ _., ... --_.,. -----·~ ... , -,..'I .. _---·--... --··-- --+-~ 1 • ; • .... .., _. 1 ... ~ ._,.; • • • --~·-··• .................... . •-r. "l. -:·-.. .. "'f • .. , --· • ·=:.-¥: = ~ ~ . ~·: :.r:.· :-~ :·: :~-l=·-:· __ ...,...'ff, ... ''_tt, . .; -.; • ---1--··-· 1-·---·--,-----..... • -{ •• -.. ~ .J .. --- -'-. ·~ ·-... .... -··--·-·-.. -.; .,.... . -'• •.. ·-·--~ -·· .. -· ' ..... ·-··-·-·-' ' __ ..; __ t·--·-. -. • -.. ... ~ .. ;. -i ·-i • -·---·r . --- --.!...--. ........ .., • --~~ ,.;_----r-----~ ----~-1 t • I " . , ~ -... • • -.... .... _.,. -·, ...._: .... '"1 -.. -.. ·-.. -· ~ .. -... ·~ :---.-. : ,.. .. ~ i .. : ; ~ . I ~" ~t ; -t 7 T ---: -: ·-~ -" i -- -• ....; .. "' .. ·-• .. -~· "' """ ,J -i ...... -J .. ~ ·-:_; ..J.._ ·~ .. .......- • • _j_ . ...!_ I . ' • I .. J-.. ' ...... I . . j t· t ~ i .J..{ i . l ' . j I -• ----l-!...1., ... ....-+_:r:: .... 4 .. ._.:.,_,_ i ~ ..,:. . ..., J, ·-.. -·· <I ! -• ~ l SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE ~\OC ~Na OC:>f-\ ·CY~t: RIVER MILE \\\.=a ( 10,000 I 20.000 30,000 I '40,000 t 50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 I 1~. I 1....-.f 11 l ' u_·~ ~J -' w > ~ 4\lo2- C( w UJ z < w ~­::E w > 0 m ~~ w w u. .. z 0 -t- 4( > w ..J w ~- ~2.- 0 ---l.~ ~ ~ -==1-_,.. ·--·_r----{ ... ____ _:.-_-=-: · ·--~---~ --~i. __ ~-~----~--~~=----_-__ Ir zz . ---+---,--:-----·-···-~ ·-·--+----+-, -:-.---. T ..• - --------+ ~~...! ~ • -...;:.__ ----- -~---~--------·---- .' '-.. ·-l ~ ..!---• r • ,; t ---~ --~ !... -· --; • -----·--....,_ :-----~ ~--... _._. .. ___,..... .. ---~-·-••• -1 ....... - -... _ ·~ ... : .. -~ ~·~::~=~ --~~~---_··_t~---= ~~-:·-. __ ":-_ --<!:~-~-=-1:·=·-=t--~~-.:;-j~~: :~~ -=-~~: -~.-~-----~-----' ' --. -. ' ____ J ___ -----, •. --·--1----~---------;---·---------4 . _ ... ~ ·--~ -·-·-"T· ----~--.-. -----~--------·---+_: __ .. ---·. -l 1 . . i. ____ J ___ -------~ ·---. -·. -1·-------------1·----.. ··---. ; ----i -----.... --i ··-·----------------~----· '--.-' 1 :.:--··---- ---·; ·-·-• . 1 -··---------~-----------~---· . ··--.J ~ --.. .= •i _----:_·-. . ---•<-==-:--: ~-~ =-: --=-=-~. ~ ~.·-:-=--= ~-~ :... J • -.. :=. -• = ~~·: · .. :..::: • : -=-= -~ ; l I •• • -· ----; -'----·------: ------·------.------------... ____ --------:-··.: ·.r:.~--: ' ~ ; ~>i:: : :~ :: ~:-~ j ~:.~ r : ~ -~--=~::~ ·-· --:~-:---=-:-_: J ~ ·:::; .. :1/: :: :-~ .. ~ ~ ~~ = . :~~ ~ ;· :..: = ~-:-:: :=-~~~~ ~-~-~=~=~:-:: : = =: ~ ~ : -=:: j: ::-:t· ::-·:= -·-.. ! ~ -.. -j --·t --·· 'i -.. -~ ------, . . .. -------·---J ••• ~ I --- . ; ----- · ---· ·--· ------, ---] -· ----.-----1-·-· --:-·· ------· ~-----; · ·--1---· ·: ·--~-----_ -----, ·---_---~~---·-l·--···-:-···--, ~----·i--:;;-.-----~--- : • . j . l .... 1 . • • : • --•. -1 -· ----L. -·--j ----: ~ . . ~ .. ,., .. ··-.. -: i : ·:·-:--: ; : : : ~ ~ ~ : . i ·::-:::: :::J ...: . : ·.:;::. . :·I : .: :..: ~ . . . - - -i . . ---.. - - . . . . . ~ -.. ---t . -------:--·--. --·-~ . -. . .. ---~---+-----------r .... t .----'-+-----!--_--_-_-_· -_ ·--1. 1 -· .. ----_ ... ---... --~-·--·-• --•• .... _.,~ --~~-!--~ -·--·~··--------~--·---~---·--·-·-! i-· ~ ---- ---i ··----~ . ---· ·--·-· i'-·---. -----~· ---~.-~_:.:·: .. --...-i• ---.. ~1--"'--.. -----:--.. ---------., ' -:::::·-; :·:·:: ~=.-.:.:_i:--~=-4~:~~~~-~r;==--~-~---~~:··~3-=:~:= :.:.~-~ Jl :·~·~·:_ == ~ ~j~~ ·------J • .. --.,. . •. :-.. ~ .. ~ . _· ·_ ~ • --1 · ·--·, · -~---•·• t · · ---6-------i--·-] -·--~~- • -• -i, . •• -j . . -· . -.. .. --~J --. --, -· -· .. -• --. . • . -!. • .. _ i ... - . • . --I ---·--. I ---• . • -. J • --• -• -• ------••• -• • • • "17... ! -: .. 1 = .· : : . .. ~ -1 ... -i . - . -..! . --.. -· ~ .. ---.J .. -.. • -- -~ . --/ ---~ t •• "" .. ..,_ <t·----1--... -:-----=-----...,.... .. ----·;----~ ·---·1 ~. ------i-• l ' i . ../' ---"1 ----. -... -~ • • • • • -• ., • - -• • ----• • • 1/---... _ . ' --.-i -. ---- . --. -.. i . . .... --. . . -. . ·-~ . . . - . 1 - __ ---_-_:; ~-:: = =·=---i ~ ~ ~-j : .. : ~--r~~:~j-~ ~~:.~j/-~~---.:. -~-1- ------~-----r-----4------~·------r---~~-----~------·-------r---3 : ~ : :. :-=:: J ~ ::-:_:: .: : ~:.:-.1-· ~--~~+:::=-~ j :~·--:-~·--: = ~~~-~------: : -. ~·- . -.. -1 . -. -.. ---. i . ---·----v~ -·--. + .• ----1 --. --. : --. -1 • ---··' ... ·----~ ---• · 1 --~ -:/-"----·-+----:----· -1 t --=-ts B-9:::~ -tD · .: --~ ~--:-. ~ :_/v )t~:.:..:.:. :.-~==-=r~~-=-~-1 __ :..=·~: : .. -: . -.. : · :-· "' -... -...... ~ - .. .. ... .; .7-" ............. j ----J ..... ~...... : ,:. ...... -.. --4 "' .. --~ ~-• ------J ---· -· ~-•. ~ -. - -i J :-:.-= .......... -····-........... ~1--...-~ ~-... ·~--... -... I ......... . .. _.., ... -·-. • · I • · j ,• __ ..,.: ..... -···-i --.. ---:--;: J i' .• ·--. -; . ·: ----· ----t-~ .. i ... ..., ---·--. ___ ,. . • .... 1 ....... ---.~ .... ---····'1-"--.. • ................... . .. ___ . "' .... ~~ --·i··-;~· :::. ~ ~ y~ . : v. = . = -:-~ -: ~ -: ~ : i' = -. -........ 1 .. .. ... -.., .; .. " -... -"'" --_,-... .... ·-.... 1 ' .. 0< .. ... • .. """ -" • -• - -.. 1 ~· ' ! ~·~----+------r-----~ A-: : 1 : : : . -• -~ . . • -:-: : ~ 1--=--=·--... ~ .. -.. J .... 1--. -- . --: .:j-t-. - .• • --• -' -• . i ---• . --. --.., --··- ' I ' , i-• ----i'"''". •· .• -···,-·---,--·-.... --··-~ . -. . -. ---. ·-•.. l -• . ---. . - . ·: ~-...... . . f--.. . . . . .. . . .. . .: -----. ·~ .. -· '1 .o.; -t • • ~ ; .. • 1 1 < • -; ~ .... . . "" .. . ~.. . ... i _., ... -.{<!..J ·~ ~~ \oOo• -. ..... ·--r- • f ' ; ' f • o I o I • o I • .-..: .!. J-i--~ • .L ... 1 "! -I -... 1 ... -· · .. • ""' ... _ .........: -_,.. ..l 1 -. j--= -=--;- . I • • "' ... ......... .... -.. ., . ..., . • • .. ~ • "" f .. • ~ ...... .. - I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE r\t.AD b lb~ Cit..f:K .5\Dt · ~Nt.l RIVER MILE llL.. \6 t 10,000 30,000 I 50,000 60,000 DISCHARGl~. CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 " ' ' . '·~ '•' . ., l)~ ~F t ': 1 •: • 'Ti:-~-~-~ j I I' 1 I ill;: : i ;--~r;-~·~!~1 --;-; ~ • : : ~ : ! ; ; ; ; I I" I ~T~I I i I ' I . • . ' f • • .. I I I I ' I '.f . I . . . . . I I ' . ' I • I ' I •• I I . ,. ! I I ' I • I I ; . t I ' t • • I · r 1 1 1 ' 1 • • ' • I • I • ( 1 1 I I • I I • 1 ' 1 1 1 ' 1 1 1 • t • • 1 1 • f I • • • , ,~1 ,. 1 • • 1:::: 11i1 ·:·I:!'' r::·1 •rr· · 1· ·l11 11·:: : ''1 "1'' • ':!•·r . -. " r ·;-r' it .. f-r·r· r·t--t-r-·· ~ .. :--I-~ :-· t-.-M-....... ' ..... -I·-.. -· ~-r-t -! ............. -· . T -+ .... J • ~; ·~· '(T\ r• .... ,_, , ... 1'0 • ' f J • .-f • 1 I t f r t f f i t I t t t ., • r f ' • t t f • • ;. " • 1 ~• .-• r t ~~'I "I. I I . . ' . 'I I ~ . I ~ I f t I • 1 ., : f f ~ • ' ' • :· f f ; , ' f ' • I t f ' I. ! ' i : I • t t I t ' • • ~. f li ltiJ', ~· ji 1 1 :,r,. 1111 l!!t :lr• [Tii 1!\~1 !·I· ~ti: CJ11i •rt ·t 1 · 1 I 1 ! 1 • , 1 1 1 l • • I 1 1 1 • • 1 • 1 1 1 • 1 1 I 1 1 1 • • • 1 • 1 r • • • • ' •• • I , 0 J t t ( , t t 1 • J • • • I . I L I I ' l '. I ! . ! ! l ' : . ' ! 1 ~ ' I I ! JU• l ' . I I : ~ • ! ! ! ' . : ' ! I ''l ! I ! ! : I I ! I ' : • I . I ' : I ' I I I ~ • I -~-! 1 I ' • , ' ( •. ' • t t l ~ t r • I • I I I t • I I .. : • ' ' t f • r f ! t I • i : : I r J t I l : f. t ' -t I " • ' ; t ,. • . , • I • I I ' I ' ' , -· ·• • r. . ~ .. I I • I I , .. ' . I I • • I l .. ,. , I . • ' . . . -I I I • i t-· t ' ' • • • I . ., • • 1 I 1 • ' ' • • r t i f ~ ' • ' * ' • • i l , t r ' ..A"'l i , ... , • 1 f 1 t • • I 1 1 i t ' • • • t c..J ,.-j-_,.., •. rt·•-r -.,-1·--.--.·-~-.-+--• r-1--,_T f"'' -r-r•rr -• r:·:·• --:n ·r·1-T">' ·r , ... ,. •. r--~--~'7·-.--r···•·•• -.--r--' I I I I I • I . I I I . ' . . I . ' .• I I I I I I I ' I I 1 I .. ' ' ' I I I I I I I • I ' I • ' ' , •• I , I 1 ; , I : ; , 1 i 1 , 1 · 1 r 11 . , I I 1 : ~ ,~ 1 . ; , I I ,, I . I , ~ , i . I I I ., 1 .1 ~, 11 . : , i I I I I I I I I ~ I I I I I ' ! I I I I I I I I I I I I ' I . I . . I ~ ' : I I I I I I • I . • I I • I I ; ' . : ! 1 ' • I ' ' . I I I I I I : . i • ' I • f f . . • t • • J ' ' ' ' I • • ; l !I l I ! I ·, I i I I I I ,. I ! I : i I I ' ~ I I I ! I • • ; •• , ! I I' \ 'II I I I i t .!. . 11· I I I I I . ,. I I . ! I ! : I I I I I I I : ! I I ! ' I I 1 I I I I : I f. t . ' ·1 l ~ ~~ I I 1 ''li ~~· 'II: t:l) I~~ l 1 11' ll '''I 'I' 1-. ~ I I ! I . ! I I 1-' I I I ., 1 ; ' I I I • I ~ ! I ' . I t I I • ' I I I I I .. I I ., ' I I I • i I I I • . . l' I I I I I :111111t1111:1t: :! :11'· 1 ::, '1 1 ! J';l :~: ~!11· ij; I~' .,,., 1:, , , 1 1 I 1 1 I 1 , 1 1 1 I , 1 I 1-1 I' . ~ 1 • . 1 , · • : ; I I l I I! I I I ! : I . ' l I I : ·, . I I l • I I I I I I I I t 1 • I • I < z 1--CIJ ::J rJJ T -Tl_1_rl-r-rTl rl--r r 1 -; 1 I ~ : i . ~ , · i ; 1 • I • , 1 f i . -• , I I I I I 'I l I ' ! I I ,. \ I 'I ! I I I· I ~ I I I f I . I l I : I f : I I I I I I ' I • I I I I . . • ., 1 I ' I I : I I I ., • . I I ' t I r 1 i I 1 r I ! i ! : ' 1 : 1 I 1 I I · t 1-~--~·t-t· ··!··t· t~ -t-1 1-1 ·f-~ + -~. , ••• ; +-r-t r ·-r-J_-+r -;·Ti··r , ~-r·t·· -~-t-i+ J .. I· I· l f. '-· I j • 1 1 . . I I • ·1 : 1. 1 I 1 • 1 I 1 I I 1 1 • : I I t I 1 1 I· ~ t I ! I I I' I t ' 1 I I • i . I I ' : I • I I ·! I • •· I • I • l ' 'I ., . .,., I· i . -. I 1 l ' ' i .! j • I •• r I I I I . r I I : • i I ' ' I I . I l I I I r 1-1 '. '· t 'I I j I I I I I I I I ,. ' f • I I ' I . ; ' I • I • ' i • ' I I I I I I 'I. I ·-l I . , 1 1 r 1 ! • , 1 I . · I • t t I ' · t f f I .... 0 w ..,., 0 a: 0. 0 -a= .... 0 w ..J w 0 a: c >- J: ~4 ~~0 .o. r(] . w ~ ~ (!)~:::: a: ceC3w J:\ll..J 0 -~~:e c w a= w Iii w Cl:Z~ ~ ~ a: UJ I I 1 • 1 1 j ; 1 1 1 1 1 1 1 t i ·j • I 1 ' I I ; ·I r t 1 ' • r 1 ·f t-·· ~-J 1· ,.,.. 1l_.ll-tl't !r·· r't!· t!i·J ~rlr ,11. 1 :1-· !i·r····:-f.!-m-,--ffiTil_m_ -;-~--.---.-~~-.. -~ --.--. .--:t ··l+t·r !.[ ll1lijj1i! ~,1! ·~;-, tl:;. •:!1 ,:.. '···: 1 Jt!·t '1~4-:-111 ' . m -' . "I I I I ~ I . I I ' I ' • ' ' • I' ' ' • I I ·r I I I ' I . I . ' • -1 I t -r-i . --t ' I t t 1 • t f " ' ; . -i-+--:·i· -·r··H·-t-T"-l-.-·~· +! "'' + ·r·•-i-r•-· 1· •-~--:· ri·,-·r r--""'t-.---~-;-r-·..--~ r-.......-r--...-, ---r ·-;-t.....--j-n+ ·t-~ • •· 1 t · 1 I • ·1 ' 1 I I I · ~ I · I I 1 1 · ! ., ' • i I I 1 t • I i :-1 I · 1 • • 1 1 ~ 1 • 1 I J 1 1 1 ! , I 1 r 1 : i , •-t . i , , I . . .. ·I I I I I ' j I • I .. .j -. I ' I . I 1-'-• I I I l I I I • ; ~ ' . ,.... I •··r .. t -r ' I . . i t 'I I I I I I ' I 1 . ! : . I ' : • ! : ! I II. ! ! . ! t I ~ • -I ! I i I I ·I '. ; I I· ., . . I ~ • l • J ! t-.... . l ' I ' ' I . I I I : ' : . l I • : ., ,. ' . I . ! I ! I I I I I • • I . I ' • I I ' l • ' • ! • ' • • t • I ' r . r I • .~. .. 'ITf ' . !I . I • • I • • • -,.---~ • --T~l-~~~-~--~r--~-.------r-~· . ' • • ·I· . I I I • I . I ' I ~ ·t· ' • • ' • I I l I • t • I I I • I ' I I ' ! I T I : ·I • I • 'I ' • • • . .., ...... ! l r I I I i ' ! • I . 'I : I I . I ' ••• • • .; I • ' I • • • • • • • • • ' ' 1 • ' I l .... . I I r I i I • . I . I • ; -• •. 1 . • .• r t-! I I I I f l I f I I ; , . I • ' • I ' • ... ' 1 • I I . I -I • . ' r • ' I • • ••• r • I ., t f I • • • , I r t ~ • •' t'! · ' I· t 1 I I j ; .I I 1 1 • 1 • • I • • 1 • • • I • I • I • 1 1 r • • I 1 o ; ! • ., ; 1 • ; r• 7 • 1 • • · I 1 I-•t .,. I . I I ' I 1 I I . I i : 1 I 1 ~ I ·I ' I . . I I I I I I I I I I r I r : I r . f I ~ . I ! 1 I 1 r ! . 1 I 1 • I ! 1 I 1 • 1 • 1 • 1 I r 1 1 • 1 1 i 1 4 i : 1 1 r 1 • 1 ! t I r ' 1· I ! 1 . -T- ~ "" I -1 ~ ~ ~ T ~ f ~ T 0 # T ~ ~ T ~-,..:.) ~ 0 0 0 -0 ., 0 0 f-o • 0 .., 0 0 i-o .. 0 .. 0 _o 0 • 0 crJ 0 0 r--o • 0 ~ 0 ~8 • 0 ... o· c z 0 0 w Cl) a: w Q. 1-w w ..... 0 -m :J 0 • w " 0:' 4( % 0 • a ~ co Q) .... .... 0 0 w ~ :l 1-z w > 1-z ~ 0 0 fl.) < m w -c N a: ....... ________ ~_,_3_A_3_,_v_3_s..,.N~3w 3AOBY .L33& • NOI.L YA313 ~~ ,:~ ~ -~1-IIIIFMIL fii; ~-. ~· liiiii '. ·' j &eli: ~....., ~.1 Iii: '*'~~-"" ~ ilii~ iiiit; .....-·~ -~ ~.._...,_. .. ~ ~ '.~~=--~~~?:----:~;::·~--;;~:-:.::~:::-:.~-~:-:-:-;::;;_ ... --~-:-;~--~~r· r, ,,____ -"'.'"4-~~-~~'f'-'"1 -;~t~ -~,-,.,-::-~:-:-~~-....7---:--;::: ..... -~ .. -~--~--·· -~"'Z ""-~ -.._.,.,-~,...,... -_,_. -~--..w·-· I p . . .. . ~ ~ • ~ ...... ~~~~lill. " ... •,j, •..) .. . -. ~' "" ,.... .. ~ :;aaL; ~:fl ~~ ,.-...-.._. ~ r; ~ ~-~ "--:--..-,.--__,..-..-. _.,.""' ....... _,_ -~~---·<·~,·-----. ~--~ ..,........,----~-:-~ -~~,_ ---~··--:---=~-- -~---jtl:'t;"~-~; >"-'!" "7-:"'~~¢~ . _,.,., ........ ' I I I -1 Jj IJJ ~J ~~ 11 470- ...J w > ~ 4lo~- < w rn z < ~ 4io4- w > 0 Ql :%2- w w LJ... 458- 45fo- 454 0 I . • --·--··.·i __ ·· ·-_-~----~ :_: : ~. ~ -~--___ ;\\ ·' B_ ~ 2 "t --~ -~ i-~--~ ... ~.:.::.--=-~ ! -----. . . --..... " -~ ·-. ---· -···--------_.., ____ _ j . i . -.•• 1 --·-·•1·· '· ---l·zte ·-·-···· .l .. ~.-. . 1 -. l • . -. • ~.---·--· -.... --.• --... ~ . -. i . . _j . J • • • -• ·--•. -t· ·----·. I ..... .; . . . • ._ • .. ~ .... j • -.. .... ... ' .. ,0. 4 -~· • -... 1 .. ·-.. ~ •H ·-·,J ,._ .......... ·----<!'-~----.. ~-··----t··-··-·-.. _..... ....... __ ~-----·--"'-·'"'"" =-~--i---1,~--··y· .. ~:~·-,.v: .. ·-~-------:.t -·--! -· --·- ~..... • ... -. .... ( ... .;._.,..,. __ ..,. _____ ,.. __ .,. ____ ...._...,. __ ,... ... t ... ~·-· ' . . . --i . . ... ~-... --•·-----·-+ ---.. ---.. ~ .. . -1-' . . . j • : : 1 : . ~ : ~ . -..... t • • . ' • 1 • ~. .. 1 . ---. . . . . . -. -i . . -4-·-=.: l' -' -----.---·--f-.-------·--· .......... -~ . .. .. . .. 1 ............ "'·• .. . l • . • .. • . "" ..... i .. . . .. ,.. ..... .. 'I' .... ""! --; .... - • ,._ .... t-· '1 -..... ~·- 1 " ...,. ··• I .• ~'t 1" •. .;. <t . -• '"1 I • • . • 1 .. ......... -t .. 4 ,._ •• .. '1' .. .. - . . _, • 'i ·-.. . : ....... T ............ - ~ .. "' ~ ~t • ... '" ...... ..,. ... ~ t • -.... .. ~r.; ••• .,. ~~ .. ~1i~ ...... ~~_.·++--~-~-·~~---~-' ,_ • ·-. ~ ..!. ~~:-:T • • •.• ~ .l ·~ ~ -. -..,;, -··-... -.... 1 ....,. 1 ... --~~ . .. ' . .... 1 .... t! .. • ........ • j -* -• ............ SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE LRX-17 RIVER MILE IJZ. (o9 I 10,000 I 20,000 I 30,000 I '40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND I'" ' ll ,1··· ! . } i f ! f ' ' ...1 w Afr2..- > w ..1 ~- < w Cf.j z < ~ "\la~- w > 0 m < 1-~\o1- w w LJ.. 0 ,.. : -• .. • ... .. -----... -• : -...... -•. ~_j ·--. -~--~-~--i . ... ... . ~T\\ ·---4-.--~ .--..,----.--·---· ---·T ---· _ I . .., "t--.l ---t·---·~ ....--._.: .. ' ---[-• • -~~J. .;-~ -1--~ __. ..:.....;.,_ ·----:--+ j ~--i----------····: ----l ·--~ -.. .:. --~ -·--·-...:.._ ~-.... ·-t----------..---··-···--~--.. - . . ---l-; _: ~---· --~~-. . --~----l------·--"t··--·-t------:-. --+--.--____ ..., ___;__. ' -·-·---_ .. t-J .... ---~ --~---·-=---+-~----: !--_-___ -..... ~----_-_ ~-~--=---=-=-1 ~--= : -~ -:::.: ·.: :: =---· -+----------··-+ --. ---------!- --·· L---• ---------------,----+-~-----... -... J '--· ·--~J------·1----~ ·-.; ... -... - .. ~ .... . ..... .. ... __ _.__ ----· --·-1· ----------------------·--; ----·-· --·· i l ·------;J_..., ___ -··----·---------·---------· ... -+-------·--·--. { _l I ...:_ • -----:-·--...,:-----7"'"': --- • .:__:_j -=·..:: : ~-. ~~== L~ ---=~=-=-=~=----=--= :~=~= : ~~--=-=·· =--~~--~ -~ =-. -··r ; ·-· ·-- I"'---.!------·-. ~ ... -·-1---·---.J--------· -------------1 ---.i--.. .J---·-·· -·---: ------·---·-----• -------~-·--:-· I ____ .. - - --. .. .... --·-· ----. ----.. --·r--... ·---~ ---------! " -._-....... • ... ·--........ -·---~·----------------:---------... • • ~--• 4 •• --• ~ ~~=1-= = . -::.: ~~--~-~-:-··----=-~ -=-·==-~=:. =-=~---~-~=-:-~---. ·==~-~-=-: ~ .: .: .:. =-: : .. =- -----------~------·-----~-----------~-----;----~-------~---~------~------+ ----.. . -.. -... i ---1 ... -. •-• • •---• • -·--------··--·•-·---... . • I \ ; --··-__ _. ·------··---··. ·-----·------.------·---·--1 -·· ----. ·-<---- . ---.! • -· • ·-· ~ I I'" ·--i---~----· . ---·• . • -·-• ... -. -~ . -• --~ ==: -~ ~ =-:·~ -= ~ =--=.::-r=~---·-=~-~ .... --. -·-· ·. -.. '-.. "'c-_.i_ --.,.----.. ' . . ·r . -···--t·-------t-: ·-. .. ---~ - -'! '"'! ' I , • _ . . _ .• l. •• __ • __ .. " .. "! ,. .. -. • • <I " -· • .. -·-·----· ... ~ •--·A ... ~-~ ...... __ ._ ........ .,, _____ .,. • --·---+--.............. --.. 1 .:. . -~ . -.. ---. --- . - . - . ---+--·-.. --. . .. ; ... -·--...... -.. - - -...... -· J ....... ----.. -....!.. ... ----.•. -.. I . ~ • , • • • ,. • -·--- -_, , --• _ --·•• -·:·-·•--• • • -··· ·• : , , , -I • ..,., • • i . • . • --~ i .. ~-!. I "' . ~=-~ 1 : ~ --~ =~~1 ~ ::-: ~-: -:-: ~=-·~-~= =~~~~= ~~ ~~=· ~--·-; y :-=. ~ : ~ ~-~~~~ ---~ ...... -··---1---·· . ------· --. ·---·---t-------l2(1 . ----· .. , .. ---J . . . .. -.... . . . --.. -. ··-+-- . --·------··-+ -··---· .. --.. -. --.. .. I - . -----1.:-~ .!-..:. ----i-·--·--1--:--·--r---··-......... ---i .. '/ -----·! . -. ----. ~-.. ·-·j · . · · -. . . 1 . -- . . ---r· ------. -·T. Z------i --. --- --~-. _. ---1. ---• • • ~ --l ---·-- . --; __ --· . -;?3" . .. -. -. • I • : -~{~-~-:~ ::-~-=1-~-~~ ~-=~~~-~-~=~~ .... --~~~-~~~-=~-~~ 1 ~.---- ~ 2tf --·~ .. 4 ~.: :-: 1 ~ .: : ~ ~--: = J. -~ ~ ~. ~~ ~ ~ : ~-~ . -----· ~ :~~: .::-.. ~ : . -. --1 -----·l-. -.. I-.----.. • ·--#-····--··-t ---·· ----i- -~--.. --. .. -·--1 --·--· --..• -•• -- . --• ----.. --• . -.. 1 • ·• • . - ---j !_-. ---~ .. ---V--V !----· ---·--r---·-. ---·· ~ .. -----•· ~·--------L_"" f---~~ I ·-·---t -·-·--• .. -• -'-~• -----... . -----' . -. ., -------.... ------+----·-_., ___ ___. --r---· --...,--..... . ··---·i .. -. ------------..:--!--· -· ·--r-----... ··-··-,;. -·-· ; . . -~ -- -·---! ---·-· z· --X---·-----.!------· ___ ..:. ----·---'i. i-CJP-_ c;~p\t(:..\J . ------1----·-J •. ------. -~------·-· ------~-----·-----' • ' ~~ ---- -·--_; -· •. -l •. :X 1 --· ----1------·--+--------~--4 . ----. ·---.. l -. . . • -4 •• -• . -·-r . . ----• ..! • --• • • -~ • .. - ---··--:··-. ---.. -1 . ---...... _ _!__ -_____ .._ __ -· • ---- --'j ---· : ... ...:.--!. •• ~---... --t·~ ....... -.. --! ----· •. ·---j . . . . ·-•. •f -• -- --.---l :%' .. . ... ' ----~ --· -------- ---·--' . . ~ ... - . . --· --. . j . ------; ---'I --... --··~ .. J • ~ -• . • ,· -.... -~ ---.-.4 ... ., • . ... -·... ~ .. ... ""·-- - _ ... _... J --. i. '/r\_--• -• ........... .:.·-·~--... -••••••••••••••••••• . ~ -. . -~-. . --' --. ---. -=-·=--= i ~ ~ . -.. ~ --.... -~·r-·-- -.. "1 • • ____ .; .j--• ___ , ____ • ---.. -... .. . . . . ---.... l ~ ----·--... --+·-·---. l . --:t-· -·--1 • ..,.. ..• --.. .,_, ... -. -... " . ..... .... "'-l ... .. .... I _____ __,_._. 1 ..... ---- --- '! .. ' t .. -: .. : .. .. ~­ -... """' t .I ,.;t - -• J • ... ------. ---. ...,....,.. -.... --.... -.,. -·~---. .: -..: -·--. -:-· --:-·--= --r--, ·--. -.... 1 - -1 ~ ... --, ..... --..,-1--__ . 1 ___ .... . --~ .:.] ·---:... ·-. ---. ~ • -: ~ ~--r --: • "'i .. ·: ~ • : -t -- .... , .. ..,-,_,. -J--• ... ~-----·*---' • c • ' ~ • • .: 1 ! --l..J.·i t , .. ~-~ .l ..... ~+ • . • . .:..._ !~ f-.! ... ., -4 -t ~ -" "' .... -1.~ ; "' -!....., ~ --, " -~ • • • • .. ~ ~ ..!_.., ... SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LR."h -\CO RIVER MILE \\~ .O'G I 10,000 1 20,000 I 30,000 I •40,000 I 50,000 60,000 DISCHARGE. CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 11 < • IIJ l'l • j JJ 11 .\ /. ' . Jf \j 484- 482- ..J w > ~480- < w (/) z ~478-:E w > 0 CD <C ·-· 4/i..IJ~ .... w w LL. .. z g474-< . > w ..J w 472- 470- 4loB 0 -< -~ ~ ...... ,-_., - -·---+---. . I t - ~ ----· -----·~--~---.. --, ... ~-·-L...l\U -U ~--------*-'~"... -·----. = ~-~1----_ -~=--= J -,---···· '-----· : <-. _:__t~"'t'U'\t"A\T Zl- _,_ ""T*-..... ...l.~---'-------;-......... _., __ .... -........ .,. --r ~-------f""'~ """': ~ -----~*·· .... ~ ---... -·~--r-··---1-----~r----·.,.-~ ---~-.~ .... ----r-·'1· ... --·~~ --j .. -. .!. ~ ,. • ., -·-t----~----y -----,-·-+-_;:. __ • -.--~-~--- -~--.. ---.... -_ _: ~--. ---+--'1~-----t· -·-;··; ; .... .,. --- ----..!.----1·---·-~ . --·-----· ----~ .. ---~. ----1------t--·---·-· ! l I ---i ---------1----.. --. --f---·-- I ---·-·-· ------------·---i·------. ·------r ----1 . ·-.. ·-------~-------~----.l. ----~------! ----+·-- I ---: -·- __ .. ___ ..!. -··--;---·-.. -.. ---·--t------~ ------1 1 ... --4-----· ~ -----· __ .. --L---~ ·-·-·-_::_-:-_-_·..,··r-·--·--_· +t-· _· ·_· _-_· :L __ _ ----·-. l -·. --;....... -·-··-·-· .-;. ----· ------1 -~ . -·. ----...,,--···-·--. ...--~----· .. ----·-_ ... _ ----~.-----·-i .. - • ~ __ .J ·---~ ----· 1 .. -.. -·-. ... ----... -·-~ --.. --+~ ~ -··-~---~· -·-..... ·-· --I -'T ---1-. ---~ -----.. --: _·--·=-~ .. -----~ ------------'·tf-·---_-_-_-_-_--_· _-_-_ .. _· __ --~---j1f---~~---·_· -~---~----~,-..... =_· ~--------ir--....:.._....;l;..·...,------r-------_-: ~-.. =--=-. - =--= --~ =---~ l.: : r = :-:.:---t· ~==·:· ~-:-=--=--~------·· . --. . ~ i -1 -... · ""'i -... -"" --.. T -~.. --_,..,_ ... _ ~ ~ . "" ~----.. - -· ~ --•. • j .. ·-·-... --. •• I . ~ • • • J •. • • i ·• -. . ·------... ~ f 1 -----• 1 ........ .J. .. --· -.• • - ; r• ··--•···---~ .·:.::··--i ~~.:=~=-· •• • ·lt . -~---.--t-·-----..----------+ -·----l!-----'·----1----•• -~.-----+--------~----·- .. • ·•--·t • • • • :·~-·.:·1 ·_·--·-.--I • ••-• -• ---·-·---· . • ., ~ .... _-~ ~ ¥-· .. --~-.., -----... -r----~----. ... -....... ! -· ~ -1, -~ · ~ ~ ... ---~ r= ~:-:-~ ==-=~ · ::·:-: :.. ~-: -~ =· ~ ·....;...-:--:-:-· ----~~-----+----~-~~----~------~------,_----·--r---~-i~~~~~~-----lr----~-·-· -------: ~~=-~ ~.i . ... ~ --. . .... .. -1 .. .. .. .. .. ... l .. -... : . - --· -~ .. ~-... .. ! --- ----...-.... ~ t I -----L-·---1-----··---=~-~ =-.-~ -·=~ _-~: :·i ~----· .. ----~ ~ 1 i 1 ... -... .... -...... ..... .. . . --·-"' ,...;_ .... ·-~ . .. • • I ·-·---·-t-----r----·--.,---......... ,-.-:·-J::_ .· ... ;~:/v~ ... :: . .:.=-=~· ·--~:·~----~ , . ~~~~ .. :::.-~----~~~~:_._·_·_--~~---+---~~~·--_-_-__ +·-·_-_._-_._~ ____ ~-------- ---]I ..• -. v·........ : ----.. ----"~·-·----···--i·--· . ~---- . ....... " .. -.-.f.--.. --....... ~ ..... -+ -·""' --.. .. -~ .. --· ,_.,. • . . . -i -.-~. ·-· ... --··-·-. .:... -..l ,--~-------1 . ! -... • --~-----·-·------+---···-....; .. i ... ; : ./_ ··:.·I .:._ ........ - ~ :·;·;· . :·: -. ~ -.. --. i ... I . ... . ,, i - ···• I j . -·--·---_..: -..-. .......... -..{ ,._,_,_ -· ------r -~-......... ~---·-· ----·--i . ---- • . I ' I -r·-----·-r--·-.-"-J~-~- ' • • .. L-· ••• •• •• ·+·-.. --T' ..... -...... -- .. ! .. ~ ---.. .. ... .; .i .... ·--"·· 1--~ . ..... -~--·1 "' SUSITNA . . i -.. . i -.. ·-I HYDROELECTRlC PROJECT ... .. '..t -. -----r-.. -r ., "'T ~ ""*' ... ... "' "!' .. ~ t L .... -!-L . .! !.-f J· .. .-..! r-: .. +~ .!. ·-·-+-_.:_.f_ ....!. . ..!.;-......... -++- .• .J. .. i l ·-. ~ --+ . 1 ' STAGE DISCHARGE CURVE LRX -lB. l RIVER MILE 1!4. j j I 10.000 I 20,000 30,000 I '40,000 I 50,000 80,000 ... 018CHARGE, CUBIC FEET PER SECOND - -· ---i -· -i--· --:----~ -----~ ~ .. --· l -· · · :em\ BTI z:t ----------·-1 ----=4--------:--·-·~3_j-----;···--·--<~: ~:: ~ _::: ~: ~ :-~~f~~~~~== :-=~ ~-~--~:I~:~-:~~.:_:,:~~~~:~ .. -----~-. .--· ~: = ~ ·.· ·_: -=-·= --~-~ -=-~~-=--=·=-=--.:.-=::·~ ~. =-=-=t·:·==-:.: ~-: --:·=. ~ ~. ·--· "' --.. .. -.. -----.:.----l ----. ---------------r-------·-----· . ---.. . . ···--~ - ·------1-----l'----· --·· --~-----·j·---·--<·-----·1 --· l ---.• -=-=-=-: = ~: ~ ---= = ~!: ~-=--=--=.: ·_:_ ~ ·:-=.: i-=-=-~-:-~~-~ =-= l -.-=----1 --. ~ .... ---~--j ----~ ·_. ---l-·_. ~---__ 1 _____ -~--·=--t ..... ~. ·---· +----·-~ --·--- ...J w > w _, 4.f:>ltr . ct w (/) z <( w 4?1\--~ w > 0 m < 0 . ---i ·----. --. ; -.. --1 - . --;·--l -----·-. --. ~ . --: -i -. • --· • .. . • -• . -·~ . -•. -I .. • • • . I . • • .. • ... -j . --. -: . . .. l --·-.. ---. --. ___ .. -........ ~. ------·----·-·t ----.1 -. ---.--. ------. . . . -. . --. . . ~ . . .. . ------. --. . . .. " ,. - . . .. " ... ... . . .. . .... .. ... . .. -_,. ... -.. -.. . -t -.... _ .... .... .. .. .1 -........ .. ' -.. ... ... . . . ... ---· . ..,.. ... .,. -t .... "" .. . --..... ,., . .. " ... ... . .... ~-~. ~--. -: . ~~. ~--~: ~=1l2f'. ~ --~-----~---~-~~-~~-~~ ~ ~ ~-~~~ .. . . , . . -I -. ~ . ---·r . -., --· -----·--~ . --------! ---· -t ----z-------r-: --------r-------;-~ • • ---• ·-• -'1 •.• -• . ~ : j . -~ ! : . . . - : . .: -~ : = ---. --. . ---. . --. - ,. ~ .. • .. .. ,1. • .. < .. 1 . --1 . . .. 4 .. ... ~--· • - -~-.. • -· -.. .. -11' • I .J. -• .. • ••---• • -•·~ •-• • 1 --~ • • 1 • • . • • ---~ •• -. -~ • ---•. ---. -• --. . --·-,.·--- .. .. .. .... • . . j-. . ... -·· .. ..( " '"' < '"' i. ... .. . .. ~ .... . "' ·····~-· -··1· SUSITNA ---+--·-r-·----·--------,..-; --·-·1---•···· ··-1- -·-1 .. ·-·l .. "1 HYDROELECTRlC PROJECT --··"t --''i'. • ,.. • I + Of • • T·-· • ·•• . STAGE DISCHARGE CURVE ... -.... -t ! .. + .. .. 1 ' .... ... . " ...... . . -. ~ . . . t -· ..... • • .. • ·l .. . .. .. ·--·1--- . . ·-;-:- "" ~~ ... -·-t ....... _....,.... • .: .. 1 ~J·-<·+" ..;. .... ! • ..... ... ... -:~ •. J .... . . T ... '"'~"""'. "'"'·~~ .. ":'";"'" ... "f .. ;;. ...... ~·~·i·t"!t•~ ~--l-_,_,_-t-r-. ~ ............... ···1!-:-.. 'it~ ... + ... -• -. . ,. t-... --! I 10,000 I 20,000 I 30,000 RIVER MILE 1\ S .2 I '40,000 I 50,000 DISCHARGE, CUBIC FEET PER SECOND 80,000 HARZA EBASCO JOINT VENTURE OCT 1983 II 11 "" ) IJ ~~ ,J 11 . J l 'j \ ) l . ' ·-" ~i ' J ill ' .. ..J w > UJ -' < w U) z < ~ ~frl w > 0 OJ < !-4CO w w LL. .. z 0 i=AS < > w ...J w 47- 41 0 ·---·-·-~--•·• • j -·-. ·•'. --···~·· •· • •----····•··-~--· I • J ·i. .. • ~ ~~=t: _--: ~-: = ! : ·-=r ·:= ~:~~ ~ .:~: =-: ~:~-1 · ~ ~ ;~ _--r~--: l ·---~-···1·-·:·-··l·· -·-.. ·-·· ... -.. • • -·• · -• • • · • • I • • -· -_. ---· -· • ·-· • -· · ---• • · 1 -~·-·-~~-· -· ~ ........ ·~-.-... -.. ~ .......... ;· . I l . . . J • . --.• . • -l -. . . !. -•• -• • -, . • • -. . -• ... :. ··!· ..... --·~·····1·--·~·-··1··· . -l . . . . : . . ~ . . " : . . : t : .. = . .; .. -~ I -. : • ·: . • ~. ~ . ~ -- . ~~---_ --+~ ~ -:-~, -:-:·~-=-i ______ ___,. . ~ --t --. _-: -=--= t-=-~-: :-~ "1' .. .. ---.--:--·-: . ... ' ~ " • . -~. ~-~-~ ·_· : : _: 1 . -. ~ :_ ·_ . : =_ :_ ~ -. :· : :.! ~-: .:· . ~ : : . : : . . . . : : -. . . t . . • . . -------. • -..• ..: . -·---. • . . • • . --• • . 1 I . --·~-1 " .. ., of ' ...... .,._ ..--~ ' I . • -. --.1 --• - ..... .,. ....... ~----~ ..... . ........... ····1·---~-------.. •1 .. -· ... ~ ....... t ............. ~~ ..... ·-.. ! ............ -... .... ·-j --------t----+----;;-' -~-+----~-~-..,. -- • • ~. • • •1• • • . - -· • • · • • T • '' • • '' •• ' • • • ' '-·•• ' • l " • • ,. ' < • •••••• j •••.• ·····--........ ~ ...... . ! ~ . ,. ----... --...f: ..--·.---. ·--... J • -.. • .. • .... .. 1 ... 1 .. . . i ~ ... ... .. . ... _.. -.. ~-.. . .. ... -... " . . --.. ... ... .. .. .. • • "" ~ ~ I • . • ~ , • ,. • ... ~ -.. -· ~-• , ..... ..., -r-.. - --· . . "l' ~ -' .. . . -+ ... --. . . . . . ·-; -j . . . . . : . : . . . . . :. ~. ~ ~ .t : ~ -~ : ~ . ~ ~ . jl ~ : .~ . : : . :i : . . : . . ~ ---+-~-~~---:-=-:I.. ~ ~ -·----t. ·-·-~-·----* '. ~----~---~ .--·: • ~ . 1 .. ~ .. ... .... i-.. .... .. •• • ... -• • ---... .... • ... .. • • t .. ~.... • lo • • ... .. "1 • ! .. .. ... -~'9' -"" * . 1 • "' 1 ... ~ -~~--+---~:----r----;-........................ ... " -.. • • .. ' 4 .. .. •• .,.. '. • I - • • • • • 1 • • . . ... , . . . • • • I • . --------j------.---+·----·+---·-·i··-·i . ~ .. ---·' .• j •••• : I "' .... .,. ... . i . ! . II' .,. • -·~-. SUSITNA HYDROELECTRlC PROJECT ·-~-...... ··~· .. -·i ,_ STAGE DISCHARGE CURVE ... • .. • ... • • 4 ... • ,. .. .. • • • 1'""': ":' ~ . .. " .. -. .. . ·• .. "" ... . ~. .. .. • ... ~ .. ... .. • . • • 1 1 .. " .. . .. ., ... -.. .. "': ... .. .. ... .,_ ~ " .. -. .. ... --! • "t .... ~ .,._ 10,000 • 20,000 I 30,000 RiVER MILE \\S .~ I '40,000 50,000 DISCHARGE, CUBIC FEET PER SECOND eo.ooo HARZA EBASCO JOINT VENTURE I 1 ' lil : ..; ~ .. , I J 5DZ- 500- .. z ~ 492-< > w ...J w 488- 48~ 0 ~ . -~ ~ ··----i.:.-=~ ~ -~ =-~ . ~-= --~ ~ .. ~ . ..:: ~ f ~~\TC n :a ! -• • ~ ---., '"·--..,~ -~---~ .,._ " T .. _.,. .,._,. ----.. ,._,. ~---~ " ..,. •· ---_. ._ -. ---... ;~ ~-·--~-· ---........ -:.---_.. . ,.._ ~-----~-~. _,._ ... _,., ---~-." ----~----·+-. . . i ·• ... ~-t .., T-•··• ~ •-;.. ___ f---_______ .,_ ~ ... ·-1--,.···-- ' . . . 1 4 • ---• . • -· ---t • l ; . j ~ . -. . .. . . ... ·• ... . . -. ~ . -. . i . . • .. .. ~ ..J .. • -.. ,., ... .. --· .. ... • -· • ., .. .. .. •• .. -f -• ~ I • .!. • • • • -_. _, • -• . •-• -• .. ... "t -.... f . . -+------+-' ---f-----:...--;-~--+----.... ---------1----... -·--------··-f· ·-· ---~· ,J ···t ··-·-1·-·----··-··-. -·_ ·. . . ·. i . ' ----+ --. •· .. ·• -... . .. .. , . ····I···· . .,._ . . . ; . ---i . . .... 1. -· • • -· .. ...... --1 ..... -T-- -.. , -... __ "1"" ____ _ • : .. :_~_ ....... ._.. -. f··--·-····-· ..... -r,.--.......... .. ...... -·--t .... """ -. . .... I -. ; -. . -l· ... ·---·. -. -. . ----!-· __ J,,..,..-! -..;. • --~-• ~ . i ... -.. 1 .... -. • t --+----1..;..' _-_-·_· ·_· +--~-.......... -+-----r-'-----1---.,-·-·-···- . /. . . ~---::. . ~ : : : : . .. -. ~-.. ~ .~ :.: : : : : .. = ~ : : "' 1 • "' .. t . ... .. • .. -! 1 .• f • -1 • j - I . 1 .. ' • -• 1 . • ····1·-·· ··--;~··· .... ,. -----·--·-···-----·--1----l--·-·t ...... i ...... ··4 -,.. .... ., ~ 'I' .. "t ., .. ! 1 SUSITNA HYDROELECTRlC PROJECT ...... ~~ ..... ~~-.... -.................. , .... I • : .. .. 1 .. .1. .; -" ...... ": • • ~. 11 .. i .. .. ... ,.., ·"' • • + ".4 ·• ... ~.. .f ,. ' . ' j I ' • ' ... • ~ .. "' ... .. . .. ~ .. 1 ~ <I'• -· .... -....-l1---t-_,_..l-----..;......~ .. ..,._;...-t------·- • .. .• .• 1 .. • • • . -. ·t .. ~ .. . . .. ... ,. l ......... "1 "' "": .. STAGE DISCHARGE CURVE LRX-!g, I I : ' 10,000 • .: ...!. .; : -., •• ! 1 ............. I I • ., -"' •. .., -: J. ·: "" i •-' ~• -t ~ .. ..;.. "" • 4---t "1 •• ~ -. 111 ... I 20,000 . ~ ~ . I I 30,000 RIVER MILE I '40,000 ' 50,000 DISCHARGE, CUCliC FEET PER SECOND 80,000 i . ! '_,;lf:i_ . J ·-1· ·: '' li 11 i } .1. 1_! i £ I~ i l .J 'll . I .. J I I ' J I} IJ ~:_I 1 ) Ill ~J 510- 508- ...J w > w ...J 5Dto- <: w en z c( ,. W5J4-~ w > 0 co <( . ~soz- w w lJ.. .. z Q f'""!\,0 1-.JU• - c( > w ..J w 498- 49lo- 494- 0 = ~---~ i ----_ -~-:-: :_-;-:::--.: _1 _ ___ _:~-::: · ~ :~ ~~} __ ~ -: :~ !?-~:0 TI '3 0 ----~. ·--·· ._ ____ , __ ...., _______ ____. ---------··----t··-. ~ ---..... ~ '""' ---___ -__ -. _-_ .-+-------.-_i--_ .-. =--+_-__ -_-~_-_-r~_-_-__ -_-__ -+-__ -_-_--_~,_~-.,-------r .. -_--_-_ ----+~_-... -.-r~-_..,.1-.,.-_-_-- ··------.. . i ...... -r--.--,-·~-.. ----r-·---,.,.......... .,._.,._ ____ ;··..,..·~--------·~ -... ~ .. --.--~ --~.---------~-----. --.,......-------r-=~-=-1.-=-~ ---~ _:_-: '"l : ~ : ·~ . -~ ~ ~------·---. ·~--.. ---------------- I ... --1 ----·-------1-·. --- ·---,J_ ----- ----·-T •• ··------·• .!.---···--• ------_J _______ -----·~-• • -----..... -...... --t---· .. ------.. ~-·t-----·--... ~-.. -'"'i .... 1 ' 1 -------r-------+------________ _;_ ___ ----~ --w· . • -t --1 -~----·t-·-------·-····-·-' ----. ··-·--·.--' -' . ___ _... ____ _ ~ . ----~ ------.. ----· -. ---. ----~ -·---~--·-"-. ----·---·-; . --i ···----· -----·-· -1 •• l .. woo ~ -... I --......... ~1 ----· --j -- .. -t -1 --' -. ·-=i~ -. ___ .. ____ ._ ----~ .. .. ......... -----~---------.. ·-·· ...... -... ---. --.... . ... I -... -1 - - . - l l. ··--~-----.! ·-····· !--1 . . .. --... -·j . ~-... + --. . ! i .. 1 -... . "' .. -. ~ ~ .. :--.. ·-~ .. -.. --r----. ., j • ---t-----·-----+----'--t------. --... -. ---------------r---r--------+----· -· I ~ •,· ·r··----· ... r 'l ----+··--·-------· r· ~ ----.-l------··· ----------l-----. • • • -. ' .j • -· --. I • • • -· , ·--•• • ....., •· ----• ~-• • ! • • f"' t -··-~-1 -~-•.•• ···-·--··-·-·-·. ~ .. -·-·i -···------·-----···-·· . • 1 . . . 1 .• .. ----1 1' - 1 ' . I i -. ------+----'1'- l • . ' -. ----t----+-. 1 • 1 i .. j -·.-·------1-----·-·------·--· ·~ 1 t . -t·. ---------1 - .• --··. 1 l I • • ,------~-----+-----+------~----~---~.:------;-----+-------- ! . -__ _. . j • I ·~...,--·-....... -. ---· . ---+-... - ·•· -!--. -. -•· . ~ ... -.. 1 -<t . i - ------. ·t·~-------·. -. --· ..,..,._.._ . ., __ -t-_,.._... ... _ ..... -.. ........ -·--~ ... ,_,!, .,.----· -----+. --·-j • ' ·---• '1 - . . ~ '1 1 .. .. ~ "' " ... t ... ----+-' -----ir-----· __ __..._ -------t,--- SUSITNA HYDR,!JELECTRlC PROJECT t 1 • 1 " . . t 10,000 i -'"I - . -• '1 • • ! . 1 : ···--t··. ; . 1 STAGE DISCHARGE CURVE LRX-20. l RIVER MILE /17. (of I 20,000 I 30,000 I '40,000 i 50,000 80,000 .. DISCHARGE. CUBIC FEET PER SECOND 11 ' ' .( I~ l j 1 I I ' '.I I < 'I ' ' ' ' I ) l . 1 l l ' i J IJI •1 1'. I : 1 ll ' .J II_ I. •' . ; II! Ill l ) JJl l ,~. i Ill ~J 5jQ- 508- -1 w > w ..J 50{o- <( w (f) z <( ~504- w > 0 m :;! ;:soi- w w LL. z Q r0') t-J \.. - c( > w -1 w 498- 0 -~---1--, --·-j«-·· ----·---~-i.- -l. -----....... -...... ---.--.. --~-~...,...,-----~ ~ r .• -····--. --• ~--··· .. ------•. ~----·· ···-· -·--~ .... ----+ ·-.. -.. . -..... ~ ~-t . _ ...... --'1 ---__ .. ·--·--·--·~ ~ ·: •. -·--.J . -· ·-·-.;-·-·---··--• -~ • ---. • ·-·--• ~ t I ' .:__ ·-•-·:__•••· --~=:~-----~---·! ... p·····--: -. .. ----·J·~-·· . . --....... ---....... -.. -_,.._ ____ ,_ --·--...... ~ ... ~--..... -.... : . .. . .. . - ~ . -~ :· = ~ : .. : : ~ = ·=·~-=--~ :· =: ~ ·: .: ·=--=·:· ~.: -·= .. :. . . . . -. . . .. -1·-. ···-... -I-·-=~-~-----. . . .. -.. /' . ~ -~~. ] -- -..... -1 ~. -.-:·~ ... _. .:·~.:_r~~-= ---~-r-----~- -1--_---~~·~:~~ f: ~-:/:.i -~·:. -------~ t ~ J i. - .. --.... 1 ... 1 .. _ - ! . . i : : L/: -: : :-r--: T: :: _ _j j . ---. --! .. -· -l l + ! .. .. 1 - t·· ·r-· --. ·-·-,._. ~ ... · .... !. • • • t . 1 1"-. --~-~ : : :r:·-_: ~ -: ~ . ~ · ~ . · I · --·-· --c-·----t-·-----·-r------;-·-:--t---·· . --- 1 .. -1 • ~ --.l -~ . -~ -. -·-. -· ~ , . . 1 ·--~----+--........ __ + 1 1 -.-·_j -~: ~: I:==-=~~~l:-:.~:~.'~.:= .... • :I · i 1 1 --I ~ . .. .. " ' l .. ' ,..,. .... .. ... -4 """ ~ : ~ I . . . . : : . . . -~ : -. : : . -:--. . t---.~ -~ ·--:-t.--~-· . L. -~ .,.J •• . I ....... ·--·j ' . I . , .. t . . . . •. 1 ~-~~ ·--1 . _, ... -. I . . • 1 I ._ .... . . '-----i----+----!------4----+-----t-----.;.------. ~ ··: .. i· ----I· -----·--+-----... ! -. -. . . . -. . .. --i -.... ---· ---- .. ·----.. . " ., *.. . ~ ~ . ... --+ -·-...... --'t ·------ --.... ·t· ·-· ' . ·---·--+ ··---. --· ··+ --..... ---.. -.....,._ --...... •••. J ---------..... -+ ··-- . -: -.. . -~ . ---. . • -,.. .... . ......... -.! . ' • 1 .. , . ~---·1···----.,. ....... .. -· ·. ·r ..,. .......... ,._ -·· ........ --· .. --:. ·--_..,_ .. _ _, -.. --~ ---1 ~--------~------+------~-------~--~~-----~----~·~---~-------~----~:·. -• ... ~.... 4-..... ..... .. • . ... .. """ .. ~ --4 . ; . • I . ' • . • I .. . .. ......... "l/0 ..f ' "'t -... -1 ... ---~-----+------1-------~----~·-----j l i . ~- ... ..,.. . .,. .. ! --+-·-1 , .. . i '~ ---· -.. -.,_,. -i -~ . ···i --r-· "i .. 1 .i ~ --~ 'i -~ • J "f . ~ .. • ..,. • ~ .,. • ~ ..,1 ~· ,... ~ ·-- ~-l~~·~·~·~~~-·-·_l4j_·+r~:_-_·~*~--+-~~-~~~-··~ ~ .. -:-... 1 .. ·-~' ~-..; .. ~ ~~· t • ~ ~ ..; t .. -i ~ ; ,. .. ~ ~· ... T' '! -'"""' •-+ • ,__ ..... -" ,,c: "" ; ...... j"""" -r"":"" • ...... ~ ... ,... ~ 1 ""' " --~ ... ... "f J ' • l ,.. ... ; SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE RIVER MILE fJ8 /"'. t • !-- I t ( 10,000 1 20,000 30,000 I '40,000 I 50,0.00 80,000 DISCHARGE, CUBIC FEET PER SECOND ... •, I • I; If; li 1··1 .. ' l ; 11. . j < ' 1: ' I 11 i j I I J I ! l I t 11 ' ' \ 1 M., ' J u; '··· 'J Ill ""·~' \ ... 1 518 ..J w > 51G w -· ~ ..J !.-, i .:.-;. c( w en z < :..J' I W ,...,.., h .. ~ ,,, .::::. .._-......- so+ 502 Q, . -----1----~-.. ..,._ -·-__ .., _____ ...,__ ~--... ----____ .. -----_. __ ""'!~ ~-;. ; : : : : : :-. ~ : : "ll. : : ~ ~ ~ . : :ji' . : ~ : ~-: ~::~ 1·: ::: . ~ . . J' ~ . . - . 1 . -•. f . . . . . . -.. ~ . . --. -. -I .. -.. -----. .. --. ~ .. ~ - ~ • .._ ~ • w ._ "" • ~t • -• ,. .,. "' I --"" ... '"'• ·--"'~--,4 '" J -• 4 ....... -.. " 1 j --· "' . .f .. --l 1 . -· .· ' '''7 .• ' •• 1 -. . . t .. I ~--+.. . l ~-. . -··-. .. . -• 1 ' --------~----~----;----------... .. ... . -. . l i ........ . ~ . ~ 1 ---·~--.... --·-+----~.-·--~ .,. . " . ,.. ~ .. ~ ., ~ .. • . t • • ... : .. • • • ·4 • • ·• ..•. l "~-----t-1 -- ' .. ·; . -. . • 1 SUSITNA HYDROELECTRIC PROJECT . : .. I ... . . . . I . t • .. • "' . , ... "" "i,. • -• • • • • • • J • ' •. : . . -• 1 .• -~ . ,. .. ... l "' ... . "' ~ . . . 't"' ·• ••·"T STAGE DISCHARGE CURVE " p.····. t···-·1·--, .• • • .., " .. + ,~ ,. ..... ' ""f "" ... ... ... ... ..... , .... f ' t • . ----~ -. ~ . . -: ~.:-: -:-i·. . . ! ...... ~ l . ' --' ~ i . . : . t ... ·-:-T • ... .... -4 " ~ "' • " ....... ,._ .. ~ ' ~ ... -· ~ I 10,000 20,000 i'30,000 RIVER MILE 119. L I '40,000 50,000 DISCHARGE, CUBIC FEET PER SECOND 60,0( HARZA EBASCO JOiNT VENTURE l l! ' ; I I i \. 'j 1'.! .. . ·J Jlj ~: l ',J- ~-; N.'.' I i ' "' 530- 525- ...1 w > ~57 .D- c( UJ CfJ z <(r- w k?Ll-~ .J-I w > 0 CD <( .... t-;... --w .... - w ~ 518- 510- 514 0 •.• j ·--. i --tt-,----. + : _=-:_·w : : __ ; _:_:_j~\1?:iTf'?J) : ;~~y--~ ~: --~~ ~H~ ;~-i:~~-~~~ ~~~~~:-~~-~t ~;::. :-:~ ~ i11 ~~---~---. .. -~-.. -~ ... ~ -----i ..... _ ... -·-· ........... ·--· ---r·--........ ,-----·--... - _ ..... ·· · · ... ~--;--·· · -·---... ... ~~--.... .. -·... ...... .. J - - -. ~ . -·--""' • ... .... ·~ .... --... ..~ . ... "t" ~ -... .. ... .. ~ .. ... •+ • ... ... • - . . I I 1 I • I ' .• ~=--. ~ : : ~ ~ i :._ : : ; . ::::=+ . : _.:-:_-: : : i :~: ::-:::: =·: : 1! . : :. : ~ . 1 .. : : • •• -. -· J • • ' • -• + . ' .. ' l . -.. -:---. . -1 .. . -. ... . . . . ·--. ' . . 1 • . . • ---·-···· ___ ~ --~---~~---~--· -~------=:--.:-::-r~ .... ;-:--.T·--~···-·;--·-:-~-.. --·. . . . . . -----.-; . -. ···-·I . . . .. . -. ---. I -. -.. ·--. -.. . .. -.. . . . J' ,... . . --. . -. -• ! . --1.. . . ... ~ . . . .l •. . • .. . ------'-- . . . . . . I -. . . -··--· .. ' .. -.. . . .. ---· .... -... -··-1-· ..... -----·---·-.. . . I l ..• • ... l ... : . . 1 ---· • . .. ······l·--: .... 1-..... 1 ......••• ·:· j ... ~-~ : -: ~ l . : ~ : . ~ : . -. . j . . 1 ~ • :· l ~ . ~ ·-. ·· : . ~ · · · · I · · · --- ---.• 1·-. ·-:--~~~~-=-~-=-~1-----~---~-~-:·-:-:-~-:--:-:--::::-~ --:: :-r-:-:---~~-: ~--:--:-1 ~-~ :-··-. . . ~ . . j . . -. -. -. . . . . . . -.... , .. -.. . .! --· • • •• • • • • . • • • • --- -••• + • • • • • • J -• • -••••••• t . . . . . . . :~. ! • i : . : . ~ . .. -....... . 1 . .. . -.. .. "' .. '1' --· ; -... i -. ~ . _..,. * ~---1 -.. -.. . . . . . ---. : . . . ~ ... -. . -. -. . .. v.. . ! r . ---·- ... ;. • • .: .. J•• •.. • •+ : -~ • •· ''j" I . : ·: ~ :-;.;t :~~:-~_:_~~-J~~.:~.:~~-:-~: ~~-~--~t--· ~~-~ --~ -t~ ~-~-~ ~- . . . : . : l . -_ : ~ ~ : 1' . . .! : ~ . t . . . . : ~ ·: : 1 : . . : ll .: : • . . . • . . . • . . • . . . . . 1' -. • . . . • . I . . -. . . . t . . . I -----~·-·· •· ,; ••.• 1-·----1---··· ~·-·· •. . . • • . • -~ -~ • I. --. • . ' • •. . . ~ • I ...... . . . ... ···i· ..... I .. I . :.:~ · 1 .:._· ! · ·~-: -·r·· ~----~--~-_. ___ :_ ___ -·--r-~---~ ~--· 1--- : ·: : i : -. . : . . : .: + : ~ : : ~ ~ · ... : j . : . -.: -. · 1 · -~ . · · · · I · ······· ·-··· ·--·j·. 'j~ .•••• :·· .• 1 "-. l. .. ~ • , • .. ! ~ ... """ 1 "' • '"! .. ... ... " ~ .... * .. . .. , f I " ~ ~ : ; : I ~ . . ; ~ : = . : ~ ~ -: ~ : ~ ~1-. . : ~ ; ~ : _· . fi ~ . ~{,! ~ . -: -• • /' ~. • • l. • ' "1 .... -·:. ,_·--=-· _ _::_:._ .:....: ___ :_: ___ _.. __ _:. __ .: . ~-~-- • ----~'""'-., .. ... .. .. : • ~ .. • .. • • • 1" .. • • ~ I _, t ' • • • ... • • • • J ••• ········--: ·• .-··I I I . . . • • ' 1 • • •. -' -• .• • .._, --~ • • .. •· . -.• ! . 1 • . ·t -• • • . --~~--~----~--~---------· ,_ . " .. . ........ ~·i· ''" --·...-·---.,~~ .. --.!..-----· ~---·--+,-~ " .. . 1 • ' . • • '1' .~ ...... I ,..,.,....,~ ,..~,.~··-'" ...... '1 • " " .. i t ... ' • I • • .... .... -.. • 1' • • ' -.. • • ~ ""; " • _,....._ .... , • • ·• .. r ~ ... '" • .. 10 • • ... • i ..;. .. ! : I . ....;.... ....... I ,. ... .... ~ . . ~ .. i . . --., ..... "'" t·~'i' .... -;, • "" "' ~t ... • - ooj: "" ....... ' .... ·~ I ' "...-r-J: ~ .. . ... ... ~·' . ~ ... • """ t .. 1. -...... ... <II ~ * ·4 .. +· ... . ., .. . ... ~ ' .,. -· ~ I SUSITNA HYDRO-ELECTRIC PROJECT SlAGE DISCHARGE CURVE RIVEtl MILE /20.3 t 10,000 20,000 30,000 i 40,000 1 -50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBAS-CO JOINT VENTURE OCT 1983 ··' -~~.(I ~_.,~ ~., ~ { ~"i f I I : f 1 t f t ! . ,I : ! ri I I I I ' I ' f I I I I t • ' t 1 r ... ~ ' I I • ' ' I , • I I • ; I I I t I f T" ' I t • ( f" • I I ' r ' , ......... ' ! t ~ 1 ' ......... . I • 1 I I I l l i. ' ' .. , I ,._. ·-· ...-:.--. ' ' • I ; .. I I I t' ' l • t • -.. ~-"' "t·· ........ ~., ... ~--· .... I I 1 I . I • I r t r ! I ' r I • ... , .. .,. .. .;} ,. I I ' f I : I : I ! I ' . ; . f • 1 I ~ • ; I ' I • I ' I I I · r •-1 ·~·· , ~ ,--· r-:-.. t : ! ' ~· ' ' • ' ' I ~ ! ~ ,• t • • • ' .. .. ' • ' r t ~ l:i 'f''! l' •11 1°'~ I• I '''II' i ( J T ._. t-T r·r t-o w ., w > 0:: ::l ~~ • ' I J I I . . ' I t I I 1 I • ' I I • ' ' I • , I r : ' ' ! I I ' • : I • • ' , ... ' : I ,. I • 1 • ! 1 0 a: Q. .o ::r. . . 3 :8 -! ! : : ; : ~ . : , r< : .. : t : : ; ; ; : : : : ; · : : , : : · : , : : I 1 t ~ • t 1 , • f .. ' ' • .,... ' • ' • • r , ' ' • • ..... I , t ... ' '" I • ' ~ I ' I I _. r ' I I • r ' • : 1 ~ I • f 1 · f 1 1 • • t f • • ' • .. t , t r ' ! • 1 • • t " • I "I , ~ ·. • I • ' I ' • ~~-~ ..... -... r-r ..... ,. -r T-···-t. -·1' -...--.-,-.. *, .... ·-r-T"' .. , t-.. ~-' --·-·-.. ......... • • ....,,. .. r·-~,.... . ., .. . l f I f I ' I ' ' ' ' • I I ' I I I • I I • 1 j I . I I I i I • • I • ' • l I I I l • •'l I I" I <( z .... 0 -a: .... 0 w -1 LU w " a: < J: ~ Jl w ....1 j I' I ~ I r i ' I I I ., ! ,. l I' .,. I . I•: I ! r ! ! j i I I f I ! i . 1 • ! ! ~ It I : I I I I I I : . I • I ! • f I I I I I I r ' I r I I I I t ' , 1 · '-h-+· . 1 ! ! " ~ 1 1 i r i ., i : 1 , 1 : , , i . • ! , 1 , ' 1 ; -CJ) ::> CIJ 0 en it -::e ~ • I T t • , t , , I t -....-r---....--i-o-..- :. 'I I I t I i I' ., I I i ., , I I I I l i ~ . I : : I I ! I I I i I I I i I • l .; I : I i . I f t I l I I ' ! I' I' I I • . I ' ' I I l r ! . . : , ' : r : I ! t I i. I : r ' ! r ' •·1 ·r I H I . ! I I I I: ! ! I I I'. I!. I I I I I I '.II I I r I 'f I I 1. r I i I • ; I I 1 I I ! I I ! ! r r. ! I . : I : , : r ~ t I ! 1-~ r r ·r . I i ! 0 a: c r. ~~ ~3 a: w > -'l11··· !i· .. · .._,. ·t,l r '1"1 'Tt··t-r -:~·1·1· ··t··r f'i .. ··:·~·r-t-1 I t·r· ·trt·t ·i tll-·i-:·r 1 1 I I I· I I 1 1 1 ' I 1 I I I 1 1 • 1· : I • 1 • • t I 1 • • • I r 1 1 • I f • ' I I I t !' II I 1 1 i ; ! ,. ' I . II ' I : I i ; • : . ' I . I : I I i r i I ; r' ,. I 'i • l I· I I I I I' I I i ,, II I I I : : ' ' ! i I . ; ! i j I I I f I " 1 •1 l 1 1 1 : , 1 , : 1 1 I 1 ! : l • · ; I , ; , 1 Cl > J: UJ a: • • 1 J • r • • ~ • t .-r-. I I I I • I I· . i I I : I I i. I l I I I I ! ! I . . ..,., -,-rr·-T I r' I l' I I I ; I I f : • I I ! • i i I r : • ! I ! I I ' l ! I ' • ., t t··r ! I I 'I~· 11'1'!'1 ~:·,It ! ~· I :• lllf !11 t ll•tl , ..... ,--,-r·~ l l ! I i I 1 I I t . r • I . ! I r I I I I I r ! . f 1 I : I I I I I I : ! I I , .• ~ I i . f : i J I ... t ..,., •. 1--· ·1· -;-+t .. -~-~-l i. ., · ·r· ·1·' t·-t ·-r-r-r~ · :-·11·-·;-r1 ~ ~· ··: •-..-·-t-r-·-~"T • t--!-r·t-""7-~ t-rrr ~-+-t-,--.-· I ' I . I I I I I l I . I . I ! I . : • l ; ! I >!< i I I : ~ ! i I ! i I l I • ! i ' I ! . . I I i I· I I ~ I· ; i . -t I • , I' I I ' I I I I r I ' I ! . ' I I l ~ I I I ' : l I : • ' I : ' • ' ' I ! ! r • I ' I I I ' ' I I . • t I I I I f. ., .. 'I • • • ! • 1 II 1 : 1 • 1 1 • • • • I • 1 1 · • • • • I 1 I 1 ! 1 • ! t t t· i 1 1 • , • r ! 1 I 1 • • • ·1 · r r • 11 '''' 1·: ,~~,1 ,,., ····!~·.: : ;.~ ... ,. 1 • 1 1 i1!.,:.1. ~-~· ;~.; :,.·1 ,.,.;.. trri-· I ' t· . I 1 I 1 : ! t ! I, I • : I • • ' • 1 1 • , , 1 • . 1 r • t • 1 • t " r · ! I TT Tl TT,.-T -TT I . ! jl .,! !I I lr I I : 1j ; ~ . ' I I m· ! T; i r ~ ;~-Tl', ~r'-~rr r r I • r I I • ' I 1 i . f ·r ., ~ I . ~-• • r· . 1 I I 1 I 1 ., . ~ I I • • I . . I 1 I . I • I ~ , • , , I ! .~. ! • • • • I . • • f • • ~ . • . • _ . -r ~-I t I f I i I I . I I i I I • ·, r f, . • ' ·,. I I . : • i I ' r I I • • • I.' ' ' I • • I . . •. i ··-I ~ • ' • ' • I I • , • w f I . r • ; • t ~ . I. -i I ' ' ' • • ' • ' • ' ' • ,. ' • . • I ' ! I ' • I ' • •• I j ' ; • r I j : ,-t· ·; . l - n-.··j-... -t-.-.l .... r··rt-t-f-·o-1-···· ·+-T.., ' H-~ -· !---. ~ •. r-1·-i· .. --, .. ~ ·4 ------. I ..... , .......... ·i--r-+---.. ,_ ..... _ -l-< ''T"' -,.. r-r -i-··-· •• · 1 j 1 ·!' ·1 l : 1 1 1 1 i · : i , . · 1 . 1 I ! · 1 • ; , : 1 ; • • 1 • 1 ~ 1 , i : 1 -• .. • • , • -t : , • • t .. •• , 1 I • 4 I I I l ! l I i I I ! .. ' ' : I . t • l I 1 ,. I I I :· . I I ! I t : ! ! • • I 't t ~ t • .. ' :· ;-• • I , •••• I . . ' I I I I l I I r I • I I • I • • I • I ' I I . . r· I ' I I I • I I· I • • • I I I • t ' • • I • . •· I I I . . ' I ' ' . . I . 1 ! .. I • ! ! . I I ! ! : t • I . . ' • ... . • I • I r l ! t ' .. .. .. r • • • r • • ,. r f ., , ; ~ • ~ ·I l } I ,. 1 I 1 • I I l !! 1 : 1 ! I i ; • ' • • r· t 1 • ; .-·; • • • • ·r · I • 1 • • •· i · • · 1 -:· ·-• .'"'i .... ,-.-, -.'-., . ~ -" ' ' ! I I I ' I ' • • ' •• , '. t ' ' r-r ... t • • t I • .. . ' • • ..... ' ' ' ... t f ,.. ... l t l ' r '·~ -to..... . ... . ,· . i 1"1 I I I I I I ' I ;. I I I I i I ' ; I I ; • ; ; • .. ; ' l • . ·I • ~ I . I f • ; I • I" • l • • i I • I r· r ' ;_ ~ • • . ' ' ' ; • • 1 I • -I •?• • f 1 ! I I f I ! I ' ' ( • J f I ~ ! ' • . t f ' • • • • J " 1 t r ' • ' r ~ ;., T • • ~ f • ', • J t ~ ..... r ., r:T ·: r n ,-r]-=1 T ·: T·; r· l -~ r1 r;-r 1-:~::1· 1; n-~~.,-~: :-~· ~ ~--~~T~··~ ;-: r;· ;::; ; · ,, .. ~ ··· :: _:: · Iiiii' 1 t!lt)! I ,,,1 11'1 !1 1 11 'I' •1·'111 I 1 1 ·1 •llr l•rt.l•t!l ••r . .J ~ ~ .. ~ --... liiii .. liil. ~ ~· ~ ~ ~ ' . ~ ICalliL ~- 0 0 0 . 0 ., 0 0 ~->o -0 ., 0 0 1-o .. 0 ~ 0 _o 0 .. 0 (I) 0 0 ~·-0 .. 0 "' 0 ~8 -0 .... o· ~-: 0 z 0 0 w Cl) a: w 0.. ..... w w I.L 0 -m :J 0 -1U CJ a: < z 0 • i5 ~~ -----~n·· __ .. _ j ~~ ' ' ~ l -'; . l . . ,-: (t) co Q) ~ t-o 0 ~} .: ! .... - 1" , • f' : ' b"':- i l i" - '. ·,·;"\ ~ ·-' ' 1:. ' ',,• I I I I I .----------------------------------------------------------~----------~ S3L.- ...1 w > ~ S3t\- < w U) z < ~5 w > 0 m 10.. - < .... 52..i.b- w w IJ.. .. z 0 ;:: 52..4;-- < > w ...J UJ 520- 0 · · ·· ---:--· ·---··· -· ---·---t·· -· 1 ,---·· ---~ · : -~~IT ~5 . =-=-... ...:.__; ...... _ ··--·i--~·-· __ I . -~ .=.:.=.: _____ ·=-=--=-=-} =--:.:---:-. . . -. ---i .;__._,.! ..;_ •• ,_.!.._....... • • ..: ------__ _!_~-------:---------: - . -·--.. ---... i ---~ ~ -~ . ~ ~ -~ ~ ~_. ~ --·-·-·-. ·-~--~__;_ ___ ----------~---.... .. -... :~qs-· . . . ·--··· -~~ . -----l-~ +·-------1-.·------f-------.;..-._ '----·---~-=1 ----...; -· . -!. ..., .... -••• -' . . -• ' I • • .......__ -'--------.----_,_ --·· -' .• ·-· -~ • . ·--. ---.---t--......,..----·-.,...--. --- - -....,.. • -I i ; ---·--!..--'---J --_ _J, -~------__ , ____ -------__ .. « ... ----• ~... ~-... _-... - ·----·--:-----~ . --' -----·-"!----«~ ----i ----·------· ..l. --·--1--· -------·--·----·-·t ---- ---~ - _ _,_ ·-· ___ .,! -----·-----t---·{ ~ ·:_ .. ·ll ____ J ----·-·-----f ---· -----+-----·---. _...,.. __ ----. --. J ·--~=----~----~--~~---+----~-----_-__ --_--_--_T-.-.-_-_•_.-_----rl.----~~-------4----• ..J t --·-----.--I • ___ ...,!-----. .!.. ·-----· --.. -----· ----·---- r---·--J . ...,.--------~ ·-· ---------.J----·-1. -----1 -·--· --.....L..-.-t ..:.. -. ·----; --~------··-:-----·-. --~ -----·----1 ---·-~-. ; I -, ~-:~: -------. --------~ --·j--·--.. ------. -·-t· . · ~--1 ~ ~--==-~ :_:-_:~_::=-=r~-==~=--=-1~~~== ~:=~~-------~~ .... -----~-------~ --·-··--···-! 1. ·---·--------------------·-----, \ . l . i ~-------J • ·---• • ..J -----, ---... -· ·-·--·--. --·-. ------+--~:: ~ :_ 1----.• =--~-:-.:-:--:--:].:.:::::...; ~-:-:· . ----: = -=-=-t . : ·i ·r • -·-t • T' • ·-•• l" -i ' -! .. -----r------·t--~------;---t . -. . . j ... ,._-..J . ---! ·---..... -,. -a . --f .......... I 1 • -... l . ! . . -. ~ j -.:. -.. . ,-~------· -· ---- -~ : ---. ----:: __ --~-----_-_-_--·-:-·: ----+-----;- =-~-~-~ ~-~~:-+· =:~-:~ ~-=-· ~ .. ---~ -_:_~_-·_:]~--~_: __ ~------·+------+-·-··-__ ··--~!:----_·-_-_--,__ .. _--_-_-_-~,------~----~~~----,------+---------· --~ ---·-- ·-----,-~--ri· .. ---,----·-·----------. ---· 1 • ----~ -_,__ - - . .! _; ! I .. , - f --.. 1 ......... - • 1 • I ---! - - ~ I '! •• -..... -.. -. . --i.. . --·--1 -..: --. :-. ·--. --i -. ·----·-:·-Jl --v - -• --l. -• ----1"'' ---·--.. -----· -. . . -"""" . : ~: -l .. ~;;j :: ~ ;.·J -~.;~ ~~ ·:.: :.:1:;~_;: -~~; ~ ~:?: 't ~ -• • ·--• • -J --•• ------J • -" • • --~ • ---· - " ........ -~ ·------... ~---~ .. --·-,---------: .. ·-··-·- ' ' .. I • • --~-·--- .: • l ' --·-~ ~·· ;~ -------... ·-· • "!' ____ ,. !.~ .. -. . -..... -- j - I '"1 -· ··-· . - - -! ---1 - . -···-::. ~ .~ ~-~%· =-:::" ·:__ ~ ~ 3---=----.---4------~--·----~----~------~~-----~-----r------·------~------~-------. ---·· .. ··--.~--,----+----------. ·- 1 . -.... ·---;----··------___ .. ----L... .. ., -_ -_--.. -_· .. ----·~-.. ... " -~- . ~ ! ·-----J -·--1 1 --1 .. _,,_. • I __ _. ~~11-... _,jj ... -... -... ... --t----·---~---: 'T--------·-~ ---·-·-------·-----.. ·---· -· . -.. ----l--/~----r-------·---,; . ----v--.~ -. ~ -· ---~--------+·-----·- .. ··-;/' ·-· .. --.!---·-. --..--~ . ··-·-. ;r----+---.... --.....-~...:..--- l. -·1---- ·--!· ... ·--· ~- i l -- . . - . l ·--I ·--..... .a . ~ - 1 ·-·-j . . -- ···-~;-- I .. '\ .. • ~J'."T' •• ·-• --.. ...._-4 1 -·-• ----' ---. h --1 ~----~------r-------:v l.---l I -• -1 • • • -r T • 1 --~ . .. ----- _ ... _------ SUSITNA HYDROELECTRlC PROJECT ·-·-""" ~ -• t -... -. ~ --.. ---:t··'1-r-+· . . ... -.... .._ ... _ ~'7"'- ' ' .. t --· • .. + ... • J_lf;J __ .. -~ . I 10,000 I ' • i ·----1---·-·-.,._-;----- S1'" AGE DISCHARGE CURVE LR'k 2"\ RIVER MILE I b 20,000 30,000 I '40,000 50.000 60,000 DtSCHARGE, CUBIC FEET PER SECOND HARZA f.BASCO JOINT VENTURE OCT 1983 IJ R ! l J -~ I :_J. ' ; ~ I I I ..J w > 530- w -3 -~~ ~- < w Cf) z < --:>..LJ w;..,Jtr;-~._; . .. --·-· .. -,._ . ~ ~ -,. ! .. ,. 'I' 1 ~ .. • ~ .,~ "' • ~ ., • ~.., - • : -·· ... ·. 1 · • • "' · • _,. I ~ : -_ : : : : : : -: : : -~ --: -~ ~ : ~ i . -. :, . :--: . . : ·: : . : : . l ·: ' . : ~ = -~~-~~ ~:-=~-~~-._ -: 1 -~---~.=-~·=::-~ ~-1~~=-~ ~-~~:~--:-~. --~~-~ ::--r--~ -:~~ ---~+ .. ~~· .. --.. ~-.$ ~--.. t -·-+• ·,.._..., ___ ·--~-----~·-·-............ -........ ; ....... -. ---1 . . . . { . ---4 • -•• -l -. -'. -. -. ------.. --. -.. i -. ---; . . -. . . : - -•• • • ~ 0 '" • 0 l •• •--• ~ -•• • -~ i • • -·••• 0 • 0 • • •· • -~-• T •• •• ~-• • ;_ • 1 • • · : ..:.-.~-~ : : ~ _ I · ~-: · . : : · :~ ~ · · ·: : -~ -~ ~ .-:·~ : : ~ j -: -~ · :_ : _ ~ · : · I = : : . ~ . . >w ·f-i···· ..... : ... t· ... : .....•.... + -·-___ .... : ... -1 ___ !, ____ .,_ 1 • I i _ ---...---· .. -' --------· --·--·-··--.--J -~ --1 g : : = .. ~ : • ~ : : -~ . :· i : ~ ~-: J .. : ·:-: ~ : L ..••. -: -. . : : . <( -~;-::~ ::·.: --~-~~.:~=~--l~-~~:~.:~~=-: ~::·~· ... : .. _._ 1. :u 532-. ··: : : : : : V---~ : ~-. = :_' --_: . : : -~ : ! : ~--~ ~ -~-:±: _-: ~ : . : . : :-~ -w :: : -. - . . . -. J_ . -1 . . ; ----·J ---., ----.. . . -. -~ -I . . LL. ::_· . ~-. -~ ..... l -1 ---~--.. . I . --~--__ ..:__=_·_. ____ _:_~·-· ~ -~7 .. . . --. : .. ---. -.. -.... ----. ---·-i .•.• . i -----· . -. ·--j. z . • -• ~-• • . • • ~ • -1 • -• ---• - -• _ _, •·•·•.-··---··• ""1 • • -• 1 • ~ . -• • • • • I --• ~ . -. ... • -• -1 -~ --.. -~ --·t·-' ------...: ~ ·-... --i . ----. : . . -j .. . . . ~]30-ll------~~--~;~·-:---~~-_-:-~--+:-·-·_-_-+-~-:-_--~~~1-_~-~---~-=4+~-~--~·-=--~~~~-~-----~--~~---~-.--~---;r---~· ---- ~ ~ ---: . ---~ . . .. . . ~ : : . : . -~-: ~p: ~ =·: : ~ 'J . ~ : ._ . . . . . . : . ti . ~ . . . . . w -... -. .. . . i -·-•. 7··--· , --~ ... ~...! .... ~.::.-=-· ·_:_:_: _· -__ ·:_ : .. :_..:.._ -1 .;. ~ . 1' . -· . ,. -. ---~ . ~ -..... •· ..... .:;. -· ·-; . ~ . -. . .. : . . .. w . --'1 •• --~. • • •• • ! . -. ~ --~---~ -.-·~ J -• l ----~ 1 .. -· . ! . . . . . . . ... .... .. ~ .. -.+ ~· • .. ~ ~ t ·-... . .... ... .. '" .. -i : -....... ~ 1 .. ... ... .._.. . "' 4 --... t " .. ......... .... ~ "' f ~ ... ~ • .-~. s-,. .. .._.. J_, 524 0 .. """" ~ t · • · .. -. .., • ,.. • i _. • .. .. • T • "'" .. .. .. ..... .. .. ... - ~ ' t·-.... -.. ' + ....• ..: ...... 'f .. .. . . . . . ... l ~ . . . ·-·.-. l .. -.. ------.'.----+----__ I ---··4-----+-; --- i . . 1 .• ... ""' ... • .. .. .. .. -. i -; . • • . --+--·--. -. --i -"' -· " .... ,. 4 -·· ..... --... i .. --. - • SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE 1 10,000 • 20,000 l 30,000 RIVER MILE I 40,000 12i.b I 50,000 DISCHARGE, CUBIC FEET PER SECOND 60,000 HARZA EBASCO JOINT VENTURE OCT 1983 I I I I IJ I !JJ._; ·~' .i ~j J)i . ·' ~j :_ ,,;i 538- _J w > w _J 53Co- c( w rn z <( W ,--.. .1 "'-~··'-~ ---1 w > 0 Lil <( ~')-- 1-.~ -......... _ w w lJ.. .. z 0 ,. __ - i=:J5U- < > w -1 w r:: ·:: ~ -._ .. ~L. c::z· -:.; (j) 524 0 ____ .... ~ ~ ~-~~: -~==~ 1 __ · .:..-=-=r.=._: 1 ....... ~=~-~ _ ~ ~-! _:_: __ fEi~\~IT .~1: · · i -·-· ---! -·· · -+--· ----1----r--... ~--~ --------· • · · --1---· · . ------i -~. --. ·-·-. ! ----------• --·---·-· --·-----·---:;_--'1"" ~ .... ----J -! .: -. -~ . ---··----~·--.,------+----··----+-.,. --·-......... : :.f0-:-~- . :::::: :.:: ~-: =:: i : -~ -~ ~ ~~~=":::.=~-l~::~=c-: ~~~ ; : ; A:: i:: . -----.; ---------~-i-------·-·T···. ~ -----·'t ............ ~--·--.... ----·-<···•. • ----T. ---·--!--• ----L---•-·---·-·-!···--··· .. -··· --.. -~ ....... ·---··,..·----· -..... ~ ... -..... -·----.. -·~·I·-·--· ... -: . _______ .:.-••• ~ •. --1------.. --·--'·-·----·· • • • ----4 -~-... , ... --.. -... --~1"""'-.... --· "---.. -.;...·=·--/. ... -.... ~ .. ~· -~·--:-~ ~:-: :--·---; -~-~---=---.. -. --·:~ -· ... ~~: :~. ~/-.: =~~;-- ----. .• • • • ., ----•. ·• -; -·----~--1·-• -:..7-~ ... ---·-. . - . -·--.... -. ' --.... + - l . . -----' ,• • • 1 ··---+----··--~--- .......... " - . 1 -~ . i . _.,.....,. ....... 1' ....... -... .., .. -' ... j ., " ~ --· ~ • 4 • : ~ .. : 1 : -~~ : ~: : ~. -.:__·=~--: .~ .. . ·-~. . ~~~~: : "~ . ~ ·---~ ...... .. ...... -. V . . -~ ·-.. . . . ~ -. ~ ----. . -.. l < •• ......... • i ... ... i . ~ i i. -• ·-··--• • ~ • • --• • • -j . / • . • . . - . . • • . .• . . • : . . -+-------:. -----+·----. y---~-~-:-: ~ ·----+--- -~-.. -·i -~ . •• ••""j ···j _, .. . . .. . ,. ..... ~ ... -. . ~-;· . -~ . ·. ·... . --. ~ ... . .. -.. , - T ... ..., .. ...... """' 1·· . .. -... j -.•••. -· .••.• ; ... --i . . ... -t ------ ... ... ... " • .. ... "" 0 -........... •• -.. 1 • .. ~.. ... -.f .. • . -. . . ' . ... _ .... t ..... -----+--·---+·-----+----~-------r-· ...__·--+-----··...------;------·--·- - -• ... .... ... -... ~ . : ..... ~--... -· ... _ .. -1· .. "" ... . 4 4 • -•. •• -• • •· + --.•• --• -· --·+· "' --- • ~-.. ..J • • .. ., • . • -i -.. -T'-· ........ - I ................. >¥-c ... ~ . .. .. ... .. " ~ --· ... ..... ....... .. ... ,. .... ' . l I .... ·-·---·--, • oof ...... 1 .... -... "1 . -. . .. • -1 • - ~----...,..-t-·-----------1!----r-----·-1-----------t-·-·-~-·--·+-·---~ ... --- - -" 1 .. ,. ..... ... .. .. , . . . ' . -' ~ . .. . . . .. .. • ! . ' . 1 . . . . ~ -. . . I ... "" . ' . --. ·-~ ..... ... .. - . . . ·-i .. . ..... • -• ··-+ • -~ • -t .... "' .... ... '. -r -.. . i .. ... .. . . . . ~ . . " . .. t • -.. ~ ,... ,,.. • - oi ,..... -•• ,_, ._..,. .. ., • • -f- J ... "! . . . . ~ i • • ~ • -r .• • -· ~ 1 . --·-...... t . ~ ·• . . . . .. ~-..-­ ·~-~ . ..,~. -----~ .. ..;. __ . . ~ I., ·• ! J, ............ J._ ~..J1 .... ~ • ..;~~;- ' t t ' "'" -f ........ -~ .. -...... 1 ~·~ .... - SUSJTNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE RIVF::: MILE 12 i. B 1 10,000 J I 20,000 I 30,000 I "40,000 I 50,000 60,000 DISCHARGE, CUBIC FEET PER SECO~ND HARZA EBASCO JOINT VENTURE OCT 1983 I . ' ~ Jl ..J w > ~ :Jb2- c: w fiJ z < ~ SlLO- w > 0 m < f-w w u. .. z 0 ;:: 55~- 4( > w ..... w ,.. 552- 0 _;_ .. ---t • -~tl.\\\BIT "){A· ------1---------~ . ."-'U, -----1-· -~-___ .. : . ---]"-. -----------~ ... .. ~ . -• -""--- 1 . ---+-....,..____:_ -~--+· ------+-~--t---. - .---f._.;........,... . ...,. ___ -1 -~---·-4 -,.·-;--, -t-----t---::-----+-·----+-------+ +-·~ _;_ -. -!-. -= -!-----· ~ -------- ---... ' -· -.. .!...,_ ! ~ ---4 ... ·----------;-----·--_._ --·--.. --· --; ~ ...... -. I ' I --'·--.--+...-·----...-,r--'--·...-+-----;'-t-----r------~·• • • ·•-~--·~-.....,. ~---~-..... -.. ·-+ -----~ ....... ....;. .• _ •• --__ • .; -...;.; •• ..1. __ ,~---~·'··-r---. _ _.____ ,--------···. --· -+------·-~-. ..J -----·t------=----1·---~f -·----·---· ---~ ---~-; _! j ' ______ '!_-__ ·_-·:_::_ -----t··----i-·-·----~--------t -----+----------1· -.. -----,.--·------...,..-~~------·-' l ___ _. __ ---------l ---r-----·-_____ l______ . --·-! 1 ·-----}_·_ -_-_--..;-4. _·_· -_-_· +t_·_----=-+----_·-_-_-r=---------1---------+~----r------.---_-r 1.-. ---:--' . - ---.t .. ------~-------:.----·-·-·i-----·--1--i_ ------··--· -· 1 i I --,-' -----1_. ---~ _ ... _ __ _ • ..-.. ~ ..... --; -. _: _--_ . ~-_-:_ .. ·. i ·---·-' r -~ • • ---:--1--· • ·--J ··-·---·-·-• ·-; ·---· ·--.. l _____ ! ----· -----•• • ___ __:__ • -_ _,_ _____ ... ·---·--r-.. I ------··--·-·_,·-- -----. --.---------, -----·-t·-·------------.-......---·--;---I --. ·--__ _. __ ----. . -·-, .... ------.. --·--·---·------·----------------.1-- _..__ ~--·--· -·. -1---·----1---·---l-----·-----L----__ _:_ ... l-.---. ' . --·-- -, ··--·---· 1 -l -. _; ---·· ---.!·--·-i .• -;------[------....!--.--- --_: J ·-------·--"" -----• -J ----J ' .. -- l ---· -j ·- ----t--·· 1 ' . ·--l ----;-__ _.. ----· --,--- -. '"1 -----·-'--···--· -----: -.. -- .. J .. --. 1 ' . l ..;----- -.. ---,!_ .. • .. -- -;·------·---4--···-.. ,-. --~ -· -----i -.... ·- . ---., .... __ ..... ~ .. . ·• . -----. -·i .. . . -., . .. -.. -----~---------+-·--__ -_ .. _--L-·~------·-_· __ --1 ________ -_. _____ ~----~~------ -·-~-----· ------··-·--·-·--···! . -- 1 • ----t- ~ -· i ~ . .,. • -~ -•1 - --'----. .J.. ----- . , ----~ -----_. '1-.. I . ··-~ --~ --r-,. ___ ---, ..... -. ---...... i -----· . __ 7 ___ ----•·-r-··----. ---, ····-·--·~-. l l -..,.. ..... --·-r--. -- !-. .• --t--·---" t ------....., ... ---+· • --~-1 ~-. ~~-. _ . --r . ___ .: -=~ ~-' _ . _ r =~-~ t:_-_-_-~. ~· ~ ·_:_ .. __ .. _-=_+::--';:1"'0::....----_·_--+ -~--_-__ -_-_-.-.. --- -----· --------------{--·. /-j - , __ --r---- . -------·-~ • 1 -i . --4 ... - -~-~ . =--:-:j ~ : ~-= I l -' -·---., . ..., ----1 ·-.. ·-.. ·-·····-···--¥-~-------. --------------.. --. -'"' .. .-1------. -_.. ... --·-" ----- -I --- -V---~---·--0,------·-·------- .. --, - . ·-t· --·-· -"i -------. .. . . . ---.. -; ----.,. . - =-:.J~-~ ~ 1--~-t - . -·-... ____ .. .; --.... -= --=.: -: ~ = -v-___ , ----=~-=~ -----· ·-_ ... ---... ., -·-... t . - t • - • ~· r--- -------J.---~ ·----·--·---r-o --·-----• L -'-+--------·----+ ------· I--- . -~·-1. ··--' lt···"----..., 1~-----~-·-----. ""T"'i ....... -.!-...:.-. -: ., •• --:-; i --r-+-o ----J ~-..... _, "----+· 1~ .... _;.-a~ ..... -.a. ---. ·-~ .... ..o:.---1 _ .. _--~ ._ ... _- ~-:. .,. --f •. , ~ i ~ .,. • ~ -.,. "1 ~ ..... --. --·-T -~-- t --' -·--·l·-- ' -• -J ·---· -I . ' .. --. ··t--·-. ---•• -·-!·-:·-:- ·---·---·---SUSITNA . ; ' i - l I -, - ~ : ~: ~--·~ = ~ ··---·-----..... _ ; -:--.. --:---HYDROELECTRIC PROJECT ..,. __ ,.. .... _ _. ~-. -.. 1 ·-i --:t·-. _r_' -•• ·-. : t -. · ----: ..!.. ~ ~, -'"""-•--.. ---_. __ .. ' ··• ~·::!...J~-r-l~ -: J ' ~ . . J • • ' ··j ..., -1-• ..j J .. j ... .: ... ~ t l __ i ..1--! ! - I . J l 1 ! . ' ~ -· .. . __ __... - •. _:...~ .. r-! • j • I- . -.. --r----- -·-----r'""" -·- ' STAGE DISCHARGE CURVE LJ:.~-2..& RIVER MILE \2 "t .4\ I 10,000 ' 20,000 30,000 I '40,000 I 50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 .) ' ' • , • t t iT l ' -~ ; """"' ' t l I ~ • :I '·I': I :I ! I ! I I 1'1 I I I I • I. • I I ~-, rr1 ··, • 1: ·1 J • •• 1 !~~} . '' t ' • • • • I ~ . I t:: , 1 til• • o( t!lt 1t•l ltltl•:lt' , ." ! •t ' • I I t I • I • t t • ' • • l I I f I t o • , I f I I IT l' I 1 I . •• I I .. t ' I B.~ f I I •t t f I I .t t • t t f t t • t t f ! • . : I ' ~ I 1 , r r 1 1 j I ' I t I I I I ~ t f • f .. ~ ~ J ' l I I l ' I : • . II I I. I. I ! I I ! 1 f ·t I r . I I : i I ; I t I I I I ; f I I ' ; : I I ' i I i r ' I I ; It t f r t J f t t I\ ; lIt t r f ( f I • 1 f' f' t o t 1 ~ ___!___ _ ~ • t I i 1 1 1 t + 1 ; 1 : • i l 1 ! : 1 1 : ; ; ·· 1· , l T -~ '; • -:-: : : --i . l • I ; ·-; : ~l-: -r :--: -·:;-;: . . . I I I ~ I 1 : ! I ! I t i i • • I ' • 1 • • • ! f I • I i I I l I • I I • ' : ! • I I . ! • I I t f r I t • I • f I • ' { P • t f ' I j f • • f • ( I I f 1 ! I I t t . . . . ' . . . . 1 ' I I l'"'*t ' ' I t I I • • • • ' I t ' • 1 ' • I t I I l "'I • I I f t i ' . ' l t • • ' t rft·-r;T-r -:r:T 1-::;-~~~ .. ~-T.~ .. ;---· .. ·~·~·;·:·,-;·r~·:-;+-;-~· ;·~-~·;·· ~-;-~·.--;·r~· Tr ~,--~- i I I !II' !. )I' I I I I I ,. II i I i ; I l • < ; I' I I I l ! : I I I I ! : I I ! ! ,. l., I I i I I ! i I I I \ I ' . . I ! t. ! l i ! I I . I : 1 I . I I . ! I : l I I I : I . l I •. ( l I . 1 1 ! ! • 1 j • 1 1 : 1 i I · 1 1 • • r • . • I 1 • • I : t 1 , ' : : 1 i I 1 I • I 1 • , : I -]1,11 .,--T", 1: ~ I i i I I I i I I ' ' I I • • -. ; : : j. ; ; ; :-:-r-r-1. I I -I l I ·i i I I . . 1 ! I '. ,. \ ' ~ ; i I i I I I . I i ! I ; I : I i I i I ! . ·: . . I I I . I I I I 1 ! ! ! ! t· I . ! I i I I I ! ~ 1 I I i I ~ I I ~ 1 I . " I I I I ! I I I I ~ I i ! I ! l ! ; I t I I I I t t I • . r . l , , l , ! , • II , ' ; I , , , , I , I , I : I I I : , • I ::I. 1-il I'• II' l:'l , .. r II ·j It;'~ I lj !If! I' · I I I · I 1 I , I 1 r j · 1 1 i 1 • ' t 1 1 ! 1 ~ 1 · ' 1 f f • 1 I ~ I I • I I • • : i . ! I r t • : I ' t t I • I . ,-r -~ I I I I I 1 I 1 ; I I 1 I i . I I ·· ~ j j. I' r 1 : 1·.· 1 ' '. • i : 1 ! I 1 ! i ! i · .. r I . I I I I I . i I ,, I I t I I i + I ' -I I i I I i ! ! I ! I 1 I I • ! • ! T -r-··t.-·· _li-t I' .l .. l.li +-1 r!. -j. r ~ 1-'1-L-l-·rr t-L . -+-r-t .. ·'. i·j· ~ t 1 • 1 fT 1 I TT I ; 1 1 , 11 . ·· r ' l 1 1 • • · t j I I 1 1 I 1 I. j ! 1 t I t I· : 1 r· 1 1 ·t • 1 • , ·t -r··! ' i r. r i I I I I I j ! I l f I ; r I I I I l . I I 1 : I I ! I I ~ I I ·-;" ~ I ! I I ! ! ~'·_I j__!_U__~ ! ~-~ : LL; ;_ L L I ' I I ~· •. I. rrl r -~iTT -,-T r • I t-~ I r r~-, ' I ; r I 1 -1 r •• , "T I 1 1 r 1 1 ~ l • 1 t ~ 1 i . !· I , I t , r t 1 , 1 1 '-f t.... . + I r I ' • 1 ' I I .; I '+ f ' i I I ! I· 1 ~ I I i I T 1. • ! -: T · t ; • • • • t • ; , ~ I l 1 i I t • t I : . . ! I . 1 ... I I .· ·-r-1·ri-tT , ... t_,..... . :-r·, I 'I illl IT'l till l''it 'I' 'II' .... .,. .... t I I i l : ! < r I 1 1 ;_I 'I I i. r I 11 I • j i ·I I l ; t ·r . + 1 I : ! ! 1 , 1 . • .! • t . 1 ! , 1 ! ~ , r 1 ••• • , • • r •. ' .. f f ·t 1 • J ' ~ r f • ' r ... -• 'T <( z t--0 ::::> en t-o w ..., 0 0: 0. 0 ,... a: 1-- 0 w ...J w 0 a: c > J: w > cc :::l 0 w C) a: <( J: 0 f/) -c w ~ < 1-m f}l \h 01 - w _.. -:e a: w > -· a: • • • 1. i i : r --i :~ ·i t -r ,. • . ·i' l'·l· .. ~r~.· :-1 •• I 1 ri ' I I mr· .... -·. t i . r 1 ! 1 ' r+r. I · -r--t-t~· I.' I I I I i I ! ' ' -~ I • l ;. i I I 'I 1 I l T I I. I ...... 1111 rffl ••Ji '!T; ' .. 1 i t t ~ i t ~ ~;. r · t .. ' ~r .-• J • I • f T T , 1 i r r 1 1 • i ·I ~· 1 ' r 1 . ~ . . . f t t t ( I I• •J + 1 f"~ · •• t-• e i ' ; It I I '1""1 1[1 f •·T-1 T"l"' t l I t I · • .; -I I t · t · f ! ·f • -t-o-r I -:--1-... ·-r -r-r;·-r--~--~ ·· • I 'f f· 1 I • I • ·t I ,. ~ t t • ! I , • f ...... r· , ·t 1 • + •• • , • ! i . ~ ·r ,. . .. , ~-· ~ . I • • 't t .~ t t' • • , ..._ ~ .. ,., .. -r~~~;-r,-~-1~~~~~-r,_~~~-r~t~~-r,-r-~~~+-~~--+-~~. ~~~~~--~-.--~~~-r~t-~-+-r+-~,~.~-r;-,-.~.~~.-~~-r--~---+~~. ' ., ' • t r· t r ,. .. ' ·• ' • • 1 r t 1 1 1 ,.""' ., ·• r ' f t ,-• ., ; 1 -• ~ • .._ ... , 1 .1 t I ·• t , • • 1 . , , • , t· 4 ... , + .. , .. , • • .. • • , , f , • r • , , • , • • t .... , ~ , , i I I t' I I I r I I I I I I • I I • ' I • • -~ I I •I • ' I -I • • I l 1 ' t I • • I t I • r ., . • I i · 1 • 1 f ; 1 ' , , • t •"', r , , , • ,. .. .. , , , , ' ' , r • t "·, ,_ • t, • r , . " • ... •-+ .. I • • . ' -r-T-T" .--rt·•t· ,. 1-·t-r· "r-t-r··~.· •1-,--t-• -1-.,.. ~-.~ ·--·•-.-. ..,_.._,_, .. ·r--r-r· -.-..-,r-. ..,.. ... ,...,. .. -rT .. t -~-·t ·~-t .• ' • l 'il 1 .1 !ill !i·· ·~i· 1 •• ! ~., •• ·:,: ~··· ,: •• ,, i, ··1i· :::Tr· I 1 1 I '1 1 I i 1 1 I I I I 1 1 I t f 1 t ! 1 1 • ! 1 : • 1 1 f ! I I r· 1 h f ! ! 1 1 • • • • . I 1 1 J . I I I 1 1 I 1 t i • r • : 1 1 I r 1 • • r ! 1 1 I 1 1 f 1 1 t 1 f t t 1 j ! 1 • • • 1 t , I r , , , • t , ! · * • • , , J t • • ~· lJl J ...9" &...9 L-{1 -, ~ T [}1 I § T a ~ !!1 IS) \Sl lO 13/\31 \i3S NV3W 3A08V !33.:1 'NOIJ. V J\313 r ~ 1 ~ ....J tR 0 0 0 .. 0 ., 0 0 1-o .. 0 10 0 0 -o ... 0 .. 0 _o 0 ... 0 (f) 0 0 ~0 • 0 "' 0 ~g .. 0 ... 0 • .. ... trflirM ~~iii l&ii Iiili lliiiii' liiii ii&ii ~ ~ ~ ~ c~ =::err· ~ -·"'f: ~ ~~~""' ......... 0 z 0 0 w en a: w 0. ..... w w u.. 0 -Ql ::) 0 . w CJ ~ ~ % 0 (I) 0 ~ I I I I I I I ]1' m ~ IJ 11 1 .i] P,i· lj 574- ..J w > w 5/1') -' IL- < w U) z < W57J-::E w > 0 m :stoB- w w u.. .. z 0 ("• t= ::.; ;J) .. l/ - < > w ...1 w SloO 0 ' i I . . . • ~-• • -• • ~ . • . . i . . -•. j . -. -- . i . -. --··--. . . . ~ . . .. . . . -. . . -.. 1 . . --1 • -. 1 . . . --. . i .. . . ... .... ---· --. '1 -. 1 -: : ~ : : . ~ l . ~ : _: l : : : _--•.. . . -.L~ . -: : ~-: ~ .. ! ::--= --. --: ·: . . ~ ~ . · ---+----+-------r----· __ ..,.__.. --.------r· ----·---------~ ---; --. . . -! . -1 . .. . ..... -------·-· ·i-··-. • • •• • • • l . .. -.. ... ..... .. ·• ,.. • ~ ~ -.... -4·..,. •. -~ -~--.... -.. --··~-.... --__, ....... ---• ~ ..... ., ... ""' .. ~. . .-: ~: < • ::: •::: :·: ~-: • ::.:{: ~:: • :·~·:·:·: '".--:···.:. :·-·-· : • •: I • • l 10.000 i 20,000 SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE LRX -28.1 I 30,000 RIVER tv11LE I '40,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 1 " I I I I I I I l il. '~ '! i 11 ..J w > < w UJ z 574- c( -r; '\ ·w .... ,. :- ~ '-' .. .; 5(o2- 5(o0 0 .. ; ( ..... - ~-:f.·.:::.:·_:::·:·]: .::·:]: ·:: .. ::t-:-; . ·j ... : .: .:£:__. : . ~-:-1 .. ~ ,. i : . . i. : ~ ~ i : __ ~ ~ ~ .: :·:··· I . -·. -~ ·_. -·-t-· ... _ : .. -----~- __ J • l . -• .. • ; : ·: : ~ :· = ~~-.: .. 1! ~·:. • -_: • • • ~ : I • ·: •. • : ~ •" • . ' • , . • ~ -• .. .. .. • .. .. • "' ~ • ·f ' -"'" ,J • ~ ... .... ' .. -" ... , ~-• -.. ,~ ... .,;_ -.. - -.. • ... -"' -....... _ "'' ... -.. -.. , .. • .. • ' . . l . . . - . . . . 1 ' • • -~ --• • • _i . -. ... . . .. -· " .. ' .J .. i : : : · . : -~ : : · . . . r · ·· ,. . 1 ·. · . . . -· .. · · -·· • . --. l - . - j . -• 1 ••.•• • 1 -------,.-t-.....-----.--' . --~-------· ---·--""f ... ---_, ... ... .. l --' •" ... - -~ .. ... l ' .. ' -~ T ... .- -. -~ ~ - -.. il'. . ·--. -· -· . 1 -..... . : . -. il : ~ . -~.. . ... ··-. . . . . -. .. .. --L-----~ . . - . . . . . . . - 1 , i I . . · 1 • • • --. -I . . -. . . . ; . . . .. 1 •• -• • • • --• -I . . ... -.... t .. .... .• .. " .. ( i .. . ... " ... ... .,. -t . -"' -i .... ..., ... " ' .... --.. ..._ .... • ~ .. • l "' ., '"' . .. ..... t •. • • • 1 . ~ : : ~ ~ . : ~ 1! . : : : ~ -~ -: : . • i . • • • : -· • . • . • • -• T • . --.• ---1----+-·----· I •••• •1 . ' -. . . . . . -~ ,, . . ... ~ . ... ... " .. l .. ... .. ... .. ........ """'..;. ..... - SUSITNA HYDROELECTRIC PROJECT • -...... .... ! " ..... .. ; . .. .. "' ~ ..... ..... . . ,.. .... STAGE DISCHARGE CURVE • .. ' ~.. ... . .. • • '! .. ·• .. ' .. .. • • <t j 'f ~ ..... ..; I . . • I ..... ~ ~~· ... • I ' .. ··-.,.__ : : : :. J : : .:- ' -.. -4 ·t .,. ........... ·~ ........ , ~ I ~ ~-....... ~ .... .; * t • • ... .. • .. • ~ ~,. -... •• I 10,000 l 20,000 l 30,000 RIVER MILE I ·4-o,ooo l2fo. 0 I 50,000 DISCHARGE, CUBIC FEET PER SECOND 60,000 HARZA EBASCO JOINT VENTURE OCT 198;3 I~ ( j 11 ~ l . 5~0- ~- _, w > w ..J S~Co- < w C/) z c( ~514- w > 0 m < .... s:rz.- w w IJ.. .. z 0 ~S=K\­ < > w ..J w 0 _·.--....... --4---:--j· ··: -·--· ---.,----~------~=-__ ::~~-j ----~f.R\\\5 . --+-,.· l . ·-~ -·- ---l ----1-----+------+-~---4-----~ ~=-+~ .J-. --;-,--;-,....: ··----:·; -~ . ------~--. ---_,__, ___ ~ ----_-,...---.-+-_---:_-_ ....... _-i-;~--,--· -·------~-----~ -· ----: ----~-. --... .. ---1 -: • -, . ----+--:-----·' ' ·-r-----!-.. -· .. -~ ...... - -._;. .. _-: . y-~· .. -.1.---... ·---.---'1'· -· --· -~·-·-~ 1'•----_ __:__~ .. ~-._....... -... ...,-T·---· -~--j--~-------... .:-... - _._. -.· ---' --·--; ____ ..;_ . ----_l---·· ---f--· ----i ••.. -. ·--., . . ---··+· ----. j ------+ ---. _ _).,_ - - -J------+---· .... ---·i -----. ----· -T- .! . . .. -· -·--f i 1 -.... . ----l-- - ------------__ ......_ ----·-·t----. ' I J ----I .. ..,~ .,..,._ ., • ' ·-==----~·------------+-·-·_-::~~~---·-·==~-----_-_-_-__ 1~--·_-__ -_._---~-------_-_-_--_._-___ -_-__ ·+----,--------r------~~----- ---··-J .. ···-··I·--· . -. ·--+----·------1·---. ___ ..:_ --- r---___ ....;._--·-- --· ·i·· -· .. : -----... . . ' .. ____ ! -... --·---· -.., ----·~ -·· --- . ---·-. ·-· ---·--. ----·-·--·-· --; --------· l _ _;, ____ -·-----·;-·---· ---.. ~ ·-------~ --·-·--------·---'"1 ---------------·-----·----r---------· ! . ------·. -.. ·---·-----------------·~ ..... - . --· --t--· ---1----.... ----·-- . ------·-----------_____ J_ •.. ' ··---·-__ ...; _____ ----_J_ -------l--. ----1-·-~ ---,---____ ..: ----- • .. ---i . -~ T'--... -, .. i . ------·---·+ ·~---------, ------ ···~-... ---1 . . . i. ' --- , ----·---------....!-----------,---.- --~----·-----+------1-----. ---·~- ... ---~ ----r-----+··-- -.J --·-------------! .... j • ---- - - -" -· -· -- -4-··-·. ... _ ·---· . . ·-------·-. --i ·-- ---.. , ----·- .. I ' ... ---·-·! -~-· .... . - 1 'T . -------- ----!-' . ·-:-. -i . -. : . • --· -I -. --------~---·-. .. ---___ .._ ___ ....,... ___ +-----.---.....--+-------r, ----+------ 1 1~ -~--_... --. ""' -·------... i .. ..,. -! ---·~ -..... ~ -.•. -........ ..J ---~------. --·--·-+-__ :-..:~-~-==-: ~ ·= ~-: ~: : .·: .. ~-: - . -.. _....!.._1. ·-___ J . . ... 'T--·--· -·-·--·-• • -•. -. I . ~ ' .. _,_,._ ----~ ~~--... ----~---~-------+--------·_·4~----------~-------__ -__ 7~----------t-------~------+----=~~-------r-------r-----·-...... ---·1-. ---·-..: __ -....:.---·-. -... ..;.---·-I -~ 1 --... , • --· '1 • ---l ~-I • --~ --i - ·-1 ' --t ~ -·---. -·· ---····----1-...:·----r----· J?2:i-·---v ........ l ----....... J ---~·...... ~ .. --.. 1--- --.L.---... -__ .,,.. .... 1 i -.. -. -------------·. -------1 -----·t · --------V---3-:--·· . ! -~~ --·----·--. --- • -.. ---A--.. ·----.... -J.. -· -.-.. 1 •• --~ ·----·-y:: _...;_ -----·-----· ~ '·= 7 1 ------••• ····-• -------··--~.:_-_:.:.j ~: ~--=-v. ~---~~ : ... =~ -... -.-----· . -·-! . - ' --' ~ ... l : 1 ... - 1 ·- ... i-· · -··· · 1 ~-· --• • ... ~ •• ----... • ·-· • i' -----.. -; - . -• ... ---1 . ... • --> ·-..... ... ........ -·-·-. .,_ 1 ------~----~~--~----~------r-----~-----r------~------r-·-------·----'"'=1-------/. _, __ --·--t--·-----~--·--·-·-·---. ./ L... ------..... _---· ------·---·-----··· ---· -~ .. -··7[ .. -~ _:_ .. _' ----~ -· -~-. --__ -._..._ ----· -----~ ......... -.,. ---.•. ..l • -------r---· --· . --··---1 .. . -------·--t------·------·+ ----··-.. -···· 1-... ... ., --·~-. ..! .. /---·· { . -----·--...1-----.. ---··------- --·-i •. -·-'!'--1 1-----... ·-.._ ______ • -__, __ _j •. ·-·-. .. .., --... --~-j_ ~:;;· ---·-~ ... _....__ --· •• ~ -·----·····--·--·---- . X . -· ~ -·-·-- . --.. ..J_ ---l, ---.!.. ---". "" .•• ---. .., .. -----..-·-~· ----,___--~----+~T---+--.....!_-~·-+----.-~---t-~-T--··--., ·-r; .. -. ·l-.. -~ -. -l------: . ·--..l ... -. -1 ~ -:-• -• _. ·h ~-.. • I • • -· • J • . .,.,I ----• ·-~-. ~ .. ,.-~ .. ...... ... .. -. ,. --: ....,. . . ; ' ' ---t-. .. ----.. • • -• 1 . , -.•• .. ___ .., .... ~ ... ~ • ,-~ --...,. ~--·-. I~-· ...................... -•••••••••••••••••• __ ·----~-~-·-i~·~·---+-·-------~~·--_-·_-__ +_~~------·----~~~-~_-_-__ ~/ r ~.; i -. , . - ~-.--.., ... , .. ..... 1' - ' ..... "\ -~ . j_ ~~-=·= ~ ---: - -·--'"1 --·-·---_ _,_ . ~ -··-. -~-- • --~-1---· ~~ ·-----,..---·- r-;• : •·· ., ·-~i .J. ·-----;---.... --~-T;-'!'-. -. ---. .. -. --... .... ---·--. ---· - ........ ·~ ...... '. ~ - 1 1 j -t-..... -~ - -...... .: .~ . • ~ .. ; ....~ . -• .... .;. .1-: +-H -,_,_ -·-~~ ~ ' I l ' 0 • ·-;-"""t- : l • SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVe LR"'-L.Cf RIVER MILE \LL,.l\ I 10,000 I 20,000 I 30,000 I '40,000 I 50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 t 550- 588- -z 0_ i=:;f/J - < > w ...J w 0 "' ..... - ' .. -----. ---·-. ---. -.. -i .. . . . . ··-----·t· -.. --------J ----. ' +J . . . - · -~-~ ~-1.~ ~ ~ ~ · ~~~ 1 ~~~-~t~ ~ : ~: ~--~ ~-~: :~==:.~-::~-=#=-:~. : -~-~ 1~~ ~L~--~L ... -.. ,. . . - . ... '.. .. -.. -~..., . ·J .. -.. ~ . . ........... ·1 ..... .... .. ... -.,.--· -....... ~-- -~-..... 4 ~ • "1 - -.. ... ~--• - ••. - T • -•··j .... : • . ·-=-r . . . ·: . --. t .... .: ... ~ -·-. . . . --.... • \ • -. , ; .. - --. : -. . . . . -; . ---1 . . -, . . . -I---··. -j.. ----j -----• . --~ . • -_, . .. • -· . . . • . -: . • . I . -. ~ -., . . -.. -. • . -< • • ·• i . ... . . , • .. .. . t • . . . . . -- .. ! •.•... l .... J. l--·-~----~ .. 4. ·••i ••• ·-·-· -. -1' • --. • ----: -• -{ • -. '";---·., • w· . . .. -.,. ·-. -1 • . --: . . t -- . . ·• • -I ' . . • . i . . ~ . . ··-.. ·-· ... --: ·-. I . ·-. : . . ' . --. -. -=--=-_ . ~. ·_·_ .:. ,_: ~--=-.::....: :. : .:. .:_ ,_:_ ___ _; ~ --=-~-:::.~~-. ---: . : . .! . ~ -·=:. -: ~ ·: ; . : ~ ~ ~ ~: : j _· -: ~ • : : : ;_:.: J7 : : :: ; l : ~-: -: : : . : . : : . : ~ : ~. ~ ·-•••• 'T • •• • • • -• , ...... ~ • .. • --• • i . -.. --..... t· -. ~ . -. . ·--~-::1::: : 1 :·:·:-I: ·! --~·:-:-:.~-r::·::_:·i··:·:-~ -~~~i-:J:~~·::-_~ ----~ - --·-J •· ---·--!--~ : . ---1 --: ·-··-. +-~----~-. . --. . . . -. . . . j . .. ; -. . . . . . . . • . . . . .. l .. ; ~ .. . "" .. . • : ... ,.. . ... ~ ~ . . " " " .. --• .. . ~ " " ., I . . ~ • .. .. j~ ... ~ .. _:·--·~· ,. .. .,. . • . • . : .. • 1!' . : ~ -, . -~ -.• . • -·. --·-. --,, i -·-. ~ ,. . ... ~ SUSITNA HYDROELECTRIC PROJECT 4 .;. .. .... ' .. -r - -...... ! :~:-~t::.:= STAGE DISCHARGE CURVE "" . .. -.. ~ ... ~ .. ' .. ' .. .. "' • • •. .. 4 i '! ... ~ ... -f ... .. -""' ""' -! •· ... ~ .. . --__ _____. ...... ....,........._... __ __..._~· ~ .. • • . ' ~ ,,. ,. ' -~ """' . .! ~ .. I • .. --. "" ' I • ~.. . .:. 7 :-.:.4.. ' .... ..: f "'I' --4 ~ ... +<:' "";"" . .., • ~ •. "j. ... .. ....; * • • ~ .... ... I 1 10,000 20,000 30,000 RIVER MILE I "40,000 DISCHARGE, CUBIC FEET PER SECOND 60,000 HARZA EBASCO JOINT VENTURE OCT 1983 ...J w > kb2.- ~S98- < w en z < ~.S9G:r- w > 0 ttl < .... 594- w w lJ.. .. z 0 i= 5~2- < > w ..J w S9(J- 0 . :. ~ : . ~ : : . . - . . ~. : ~ . I . . . . . -. I . . . . -.--... -· . . ~ : = : : . . i . . -• -l . • . • -·-: ..• __ 11 . . .. . . • . -· . . . l ·• . . . . . : 1 . --• . . . . • . • . . • . -. . i_~. • . ~ . . ~ -_...:_ ---!--~--· --·--·---. ----r - -·---. l .. --- 1 . ..., . . ~ . . -. • . . -• . . . ... --. -i -.. ... . r .... . -l .. . . . . . J • . . • -• • • • • • . • • -•.•• -• • ... -·-.. • • -• --••• -• • -• • • -• • • t • • . • ~-~ ~ ~ ~ -~ . • -~ -1 :. ~ -4 : ~i : : . : ~ : -~ ~ ~ ~~ ~ : . : : ---~. .. ~ t ~ . ~ ~ ••.•• "/ ••• 1 •••.• . ! I ' . -f . ·~·-. • -· . --' ' . " . I :~:· :_: . ' :_:~~~:~.:p--~-~:: .. ~ .... :: :-~-~: .. :.,. ~j··. ·::.~~-- -• ., • • • 1 -----r----~------·...,. ···-- !: .. " .. " .. ..... .. .... . ~-~ .. . ... .. . ...... , .. .. .. .. • • • 'T • . • . 1 •• -' -•· •.• ·t • ~ -• • . • • ; . • • • • . • : : : : : . : : . . . . I : : . . . . . . -t ---· • . .. ., . . -. . ·--. . . . . " . . -. ... ...,. 1 ... -..II ..... 'II i ~+ ~ ~ • 1" ...... -• ·----------------~ : l. ~ • • • I I -. . i .. "' ... ' . f • .. .. -., 1 ...... SUSITNA I ···-1· .. . . • ..j. .... .... 1 .. -· HYDROELECTRlC PROJECT ... ... --.., .. .. ... i .. ~ -......... ""'! 10• • - . ! . .. . ~ . ., -.. .. "" -·-··}···~ STAGE DISCHARGE CURVE : -4 "" • • ... ... ~. ~- .. .. . .. ' . ~ -· --~ -~ -"' . --- .. • • ~"' .! ..... • .... ' I ' .. + <j ..!. ! ............. J .......... II>""'"" •·;~t·-'·T•"f• -t .. • • ;o..o.ol. "!"' .. , .. . . .. -i ........ .. ... ..... .. "" • ' .. " ... ,l ,..,. 1 10,000 I 20,000 I 30,000 RIVER MILE I '40,000 12.8. 25 I 50,000 DISCHARGE, CUBIC FEET PER SECOND l 60,000 HARZA EBASCO JOINT .. VENTURE OCT 1983 w I' 1.11.. .. z ~~L- < > w ..J w ·----· · · : · · --· ;_ --· 1 · --·-·· · ~ · -· ~ -· ·1U\\\\:>n 45 --~·-+ ·---· ----:• !~-... ~ -·----· .;.._ j. -··· .. --: .... -·-. ··------. . ~ :_i =:::::-=-~~-1-~-= =-= '":': :._..! __ :_ -=·==--====~ =~-=--=~--=··i·~~ .::. :: -----~-+-· ~ --.-.--. . . :--. . . _,,._ ._,.; ··~ • .. _, ~• "' ,0-• • T --•-• -•"' • __ _.,,...... •·-----.. _.. ... __ .,-......_ ~ •-• ·; ., •• + -..,. • ~-" _. "' ............ ---t--... .. ... • ~--· --.:.. -......... ----~----t------.----,.... ... -_..._ .......... ___ ...... .. -.... --r-~ .. -..... "t . ___ ,... ..... -~-f .... -· --· -~ .... --..... ·~--~ -r------.----.----------·--~ ....... - -~·-· ' ; ..... . ----·-~---.. -~ . -------· ~------·--·-·--~-1 --·---,--· . ·---~ > • ·--• -•• __ ..;. ___ .. _ .. • I ,. t ~·=!::.::: ::-:; ·_·:-::: :E~~:: ___ ~-~~~.i ~--~-~ ~·k·: ~~-:; .. :i,.. : : ~ -• ""T • • . ~ ' -~---~-------~----· ·-----+--I 1 . ' .... .... -.... + ... ... : • . ........ ,... .. . ._ ... .. • ~ ... .. • ""~ ..• 1. •. • •. :::1:.:. ·+·-·---... -· ..... l, .... j ••• , •• ' •• .... ·• .. ~ ,. ... ... • : • f -... --.... 1 --.... .. -A ~~ ...... """ ... i .. .. .... ·-.......... ; .. --~ ... ~• 1 • ~ ~ # .. ,... '!i "' • ... . ~ "" ... 1 • .. ... ... T .... .. ScrD-·--------11--......._--+-....__ .. -~_-~-t---. 0 ' ... .. .. • . • .. • ... • .. . • "* • r --.... f • ·_ : •• : : ~ : ~ : : : ~ ·i : -~-- . . .. .. . ..; .... t . -------+--.!..---~-----J t ........ "''I : . : : 1-. :·:. I ,. . i ,.. ·• • -t •r~ " - SUSITNA HYDROELECTRIC PROJECT .... ..,-.,~., ··~·~··-..-STAGE DISCHARGE CURVE of.. ... "! ........ ~ ........ r·· ........... - . "' ! .. " • ... • .. ......... i -... , """- .. 1" ~ • t ~ 'f .... ... -·-.., -4 ., ...... ?_.. ' "' .. ·• ..:.. ~~ ..... -..... .i-. t ; ,.... .. t ... .......:: ... ~-:-" . ' .,.. 4 "" • ,.,.;. T ... _. ,-... "' .. ~ -~~- • • ... --...... -· ..... • ; I . • --•--'--1 • I 10,000 I 20,000 I 30,000 RIVER MILE I '40,000 128.40 I 50,000 DISCHARGE, CUBIC FEET PER SECOND 60,000 HARZA EBASCO JOINT VENTURE OCT 1983 ..J w > ~1.;00- c: w en z < w5q%- :E w > 0 m < .... 5t:tlo- w w u. • z 0 t= 5'14- c: > w ..J w SCfZ.- 59Cr- 0 -· · --~· ·· ----1 · · -----··---,--· -"---· ··--·•· ~-~~-:.-~ _:._:~~:J~l.\B IT.~ ·-·~-----~---.--!-+ ·-• I .--... --+·-.· -;-T --. -~ --··--+-,----+---~----------~~ .. -. . ··----.. ---+ .;.~ ~ -· : ·-· -,-; .. "'"' ·--i·"-I i . .. ----· l. -·• ---.. -·--·--; • . ·--.;. ! ___ ; ___ +-------~·~· ·-·--··-···· .. -----..!. +j·~-'"; 1 - -.. -.. --! .. -: • ~ "--~ • ·-· ... _._..... • . ___ ,.......;.--.......;!----·--~ --'7-· --r-----. --~ ·--.._ ____ . ---:-.. . ; _...:.__ ~------__ .;. __ ·1·--·----'----·-T-+-~ -!-·---~-:=-=: J ----· ~ ------~---~-f--· --·---:----~-~------·,-.. ---·--+·-.. --~"· --. --·--r . ·-·~-'1-- __ :1----· . --=--___ j __ -~ ~ • ---------+i·------ ---~·-------tr------4-----1------ I ---... ---' . . -·· ... i ... -... ··----1-----·-----1--:..~---· -·------·4 --·-·-t-------·: . 1 I .i ..... ·-···~ ---~·--~ . ----·-··--. ! -·----·-· __.__---• ----+-----,-·- I t t • •----~· ~ --. ~ ------+---.---·---+-·------.....----·-• ---·!. -----·--~---.. -+ ----------· ----•• -·---·-~ .... --·· .. --~ --·-·-... ----· ---·· -----j ----j ----·-_ .... --. -·-.----.. -_._ -------··1-· ----!··-·--. ----4 -•---_"_"'_ ~ --· _., ---·--------~----- -•o • ---.. -·.-.. ··----. ---1-·---.:. ----------::--·-----------·· . ·-- j . , . . ... -----. --... ------------·--·-t. . . I:,---.... --•-· ... ---------~---·~-.. ---t--__ ._.!,.. __ .,. ______ .._;,__·1-'-... --::,:,..;~-'":-.. ---~ .. ----·--' -~ I ·--·.,-- =--= .. ~ .1 ~.--.!. -·--· -l.. ------... --·--·-·---·--··-.,...----·--.• - -~l -----i ----- ----.:, ______ -------~ _____ T .. ---· --.-_j------j ---- ~ -. --·: ~ .:. ~-i --~ ~ ... : ~ =--~~~: =~:-:-=.=~=-=t·: : -=-=~ . . "1 : ~ .:..::::.. : ·.: ~ : ·: . .: ::... -·--·t· --... ~ .. ; I i ! .. ____ -i : : .:·=~---=--=-~--~-.=._:--__ ::~ ... ! . ... ;--··40----,·-....... -. ·-· --~: --.-···;-----.--1----·--.... ----..------+-. . --·---"-+---_;_ __ _ • 'l • -·-• .~·-· --------·---• --·.. • • ---.... -• • ••• ~ --....... J-.. -.... -·--· __ _) ---.. ----·-' -·-.. --~--1 . . ____ ,J _: ~ ----------· ·---.• -•· : • --· i ~ - . - ----i. --;--· 1-··-------·---; ~---.--·--t -----.. ----... ----1----v ---!---.. __ :=J'--~--·----1 ----~,. ···--'·.'t)!·,%[··. ·--t---· .. r···. --r-·-:-··--,J ----1 .. ·--·-·--: ~ y-.. ,.. .. -'T-------~ l-"-----. ...:::. :.-!_--·-- . -., i -~ I ·;-- -4 .. -l ... --~--~:.....~-· ·-: --+-~--.. -_·-x-· ; -~--=_-_ .. _: .. :;r.;~ ~~ ~-:~~-:~ ~ ;~.: .,--... --. j ~ - 1 ----r-----.. ---..., --- . t -.. • -... ---1----------""!"" ··-· -·---- l--. ~7--~ ---~ 1V. ~.: ~ . --·-; ~ . 1 J. - I •• ----• ·-... ---. -·-~·-;--·--- ____ _. ... __ ,..~-·~ ·-~-·-.,..... __ .. --· -•• ·1 ... -----t -----. ""' --~ .. ~ -' • """'! ·---·. ~ ~ ---.. . ---·-r ·-· ,. ____ . --·-- . .. ·- --· -· l • J I 1 . i . __ _. L .. _ • -•-31 . .-... J·:·.:.-·--·-· , .. --------··· -·-· ~-··---· _ .... -~ . . . I ' .: :-·.~ .:-~ -:-: :·:· --·-· 1._.:-= ·.: --·-; . • . I --~ .-!. -r--___ .. ---.. --1-----· -- ------·--·I _,_j -·---._J-----r---·--"'1-.. J • ---·--4 • ----1 , .. _ "!. ·--· l.- _.,_ ..• ! ......... -• ... ~ . . ..... ... • 1 ·--.. ~ ·4 ----·--· --I-..---... l -; .• . -----. -. --• 1 -~ ..... . . . -. ·-·-~-~--·-· -...... ---: --·~---) • ----1 .... -... --1 ~ . ......., -"l --~--····---,-..,..-.. _~_~· J; ~ -~ ~ ; ... .:.: : i :. .. !, __ • .• ·op·~.:~ -~ .:. '. --- -.... ~ .... ~ 4 ~-.......... -------. -.-.... .... -i ; . --...... ; ~ .... . --· --·····················---~~~--~----~-----~----~~- ----.l -..,. ... _ ..... 1 l -. .,. --~ . ---........ ~ ... --4 - -., - .. --'j--·; -------~--~---+------ _., ... ..,,.... --4 ' • -~ .. 4 ..... i ;_ T., 11 . • 'T ~ .. -·~-.. ~­.. , . ·-. - . ---_,_ ··--.. 1---~ . ·------1·---- .------i-·· . .,.. .. ··----..... -. --· .. --~ -.- --~--7·- I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE lR."k --:> l RIVER MILE \ 2.10.lot:.. I 10,000 l 20,000 30,000 I '40,000 I 50,000 80,000 DISCHARGE. CUBIC FEET PER SECOND HARZA EeASCO JOINT VENTURE OCT 1983 •.~ r.1 ·iJ ~~ I . l ' . I ·~ ~~··-· -------------------------------------------------------------, I. A.A_ I I lf .. ;l.f ~nz-w-. ' ..J w > w ,..., ) ..J v.~) ... - 41( w U) z < Wr-J;- ::E.: 0 w > 0 m <( -'"I h',.,l.o - .... v·· w w u. z 0 -.... < > w ..J LU 590- 5BB 0 . -·---·1-. --.. --· .... --. -;·"' ...... --·· j • ~\\\ 1::>\\ <t ~.:.:~~ J --·. -----··--+-----~----~ ---_.! -~ ~-~ .. -= . ~--. ----------.. --i·---:-! -----·-.. ··-.. ·-····-i· ---·---1 ......... -....:,._ ... ·-·-~-... w .... ·-~---+--· ----~ --~--_... -·---·--- ' . -~------+----~·--r·----.-· -82-- __ __,... 4 _,.-_,...., ........ ~---............ ,.._ ~--. _.....,._ .... ·--""-""'--~·-...... ... -~ -• ..,. .. _ ~ .... - . T .. .. .. ____ , ....... -+··..,.-~~· ~ . .,.. • .,.,__ --~---:_ . .,;.. __ ,_""t-______ .,._~-__ _,_ • ,.. __ ,.--.... ... -... ..-.., • ... " • _.,. ___ ~ .,_ ·--.,.. ~ ... ._.. .,.._..., ___ --.,._., -.4 .. ---........ -~---+--··--~----·----· .......... --- ---·-~.. .: ... .,....-~---·--.. ··---· --....... -.... ...__..,!. -·---· .. -~ ------• • • -.. " ..:_ ___ _ . -- " 1 1""' ..•• 1· T'-.... ·-"" -: ..... -1 j I' ··-+··--j --+-~----t-----IL.-----.------4----··-· ~------·+j---- . . . ~ • 1 i - --+-----+-... --t .. ' ~ 4 .......... ~ ~ ..... 1:"' ....... __ ..,.__ ·---~1·-~ ... -· ... .. -· __ , , ... --·---·-· ~ -.. ··---·-1 . l . -~ -. -.. -. .. ; ~~: ··---,_ -------f -.• -. • : ------~--------~------~---------~-------Ll--------~----------·-----1-----------------+-----~---- ... : v:-~ . . • 1 ... .. .. . l • • • .• -1 • • • . , ... 4 -+ j I ; ... -., . ··-l-- ••• -·t --· .. + .... -.. ,. .... .. ·+ ---+-------+------+------+------1------.... ------+-·-----....,.. .. ...,. .. ~ ---·-. . -i ..... ··--------., . ... . _ .. • . . . . -. ~ -- I ' . 1 -.{ . 1 -. ' -:/. ~ :: --1--t ---~-----~-~--+---~~----+-·-·---!----lf..------;----1--·--...... _ --- : ~~-... 1 • :. -• .(. -· T "' ' " ..., ~ J 1 ... -"'t ~~"'--~-............ --+ • " • : _1 • -i·--.,.. .......... -...... _ .. ..;..._ 1 ~ • ~ ·~ 1 .,_,_, ...,. ... -"" -"-..... + ., ___ ... -- ----~~----+------+------~----~-----+------t-----4------~r------+------------ ... ......... --~ .. _ .... L •... " ..... ~ .. --.. -•. --·--. -.... -....... -.. --~-1 • 1 I • •· • •·--·-·-· ·--4 • 1 .. ..,..... .. ~01' .. -......... ·--·-_..,. ... --.. + ... ....._ __ 1 ____ -+ -..........-4-· .._ ____ ~-. _____ !-...1----+------·:.......-------+-----L---t----.. . . ... •-r"'-.., ., j . ' . , ·I • ... ..,. -'1 ! ~ I ' . . ' 1 -·-" ... -+--·-·-· -.... • i • ... .. ·• t " ,.. "t i • ·+ . -... ; .. '"" ... ~ ~ 1' .~ .. ·t .... . .. . SUSITNA . • 4 ... l HYDROELECTR'IC PROJECT .. ~ STAGE DISCHARGE CURVE . . .. • • .. ,.. • ~ '"" 't' ... "" .... .. . t ., """'! "" ~--+-------.... f--o-----+-1--+--T--!-+-..----........;.. • ..,..-1- : -• • ... • .:. f ...• ~..: •• • I 1 10,000 .. ' ~ < I ... ~ • + .: i t ·~ot ·i-.,;.~ . ! • ,J. 1' ~ ... . ! 1 30,000 RIVER MILE I '40,000 128. q I 50,0~0 DISCHARGE~ CUBIC FEET PER SECOND f 80,000 HARZA EBASCO JOINT VENTURE -p--' . I I I ; ' -T ~;: l I : ' : ! • I t I • I • : : I ' . ,. I ' 0 t • . r f ~ i : ~ I ~ • I I • , I , I i i , • l • I •• l l .. ; ·r l I I • I l : .. t • "' t 't l i · ' r • 1 t: · I ; · • t .. .. • · ,.. -... · I · -• • ~ • t"'· ·-·· • · i ~ · · ·· " r , ~ ·1 -• ~ J.. • · · i ;·-t·~ i 'T i I l 'I I : I I • I I I l t I 1 t ' I I I • I I I I " II t • I ! 1 ! i i : I I I I : I I . , ' ' . ' ' 1 I I ! I i I I l • I I ... " -: ... t f"'''"" ... ... I' : j ; I I : I I .. i I I f I i : I I I . I .. r-,-· ··--\·· ., . ' ! ' f ' 1 t f : ! : .. 't ' • ' I ~ ., . . . I : i "'l" ...... . j I ! t I • I I f ' t I I ' ' i ·r· ; .• ;.l-1 T-;-;fj""'f" :-t- ' I ! t 1 I I t I • : . • _l. • ' ' I ,. "t """f"'• ·r- I I ' -, : f I r I I ' I . . . • i ! • ' I t ' i l ! . ' ' • f I t . ' I . I . • ' T ... t t ... I . I . I ' ; I -- I I r ., ' ~ . .~ .. ... .... ,~·--·· T f ~ I I ; ! i l ! ' t ' ' • I I I II ! • I I • ' I l -• I . I . ...,.... . ' ! I I t t t t ' I f ' J ' f I ' I t I ( t f . ~ ! • . . " 1 1 ! t • j l ; l 'l 1 .. ! J t· t • • I I I' 1 I t' I I i. I ] 1 i i t f : i : l l ' I + • • I t I 1 ·1 1 1 1 • • t • l ; • f : ; • i r i I • • t I ' I lt j , t I ~ I * ' ( • f, 1 l ' I .. r I I ' I I I I I I ' ' I ' ' t I ' , t • , I • • t r ' ' • ' I . . ' ' ' ' • I t ' • I 1 • · , J . , • . t t " · ' i .,. ' 1 t • I"" I . I l ! ! ! ! I T I • • i • l l . . i . . I I ! : ~ ! : • I I • t t • • : I t t • ' I ' I ' f I I I I r f j I • ' 1 1 • I 1 ' • • 1 1 1 I 1 1 f ; 1 1 ! • • t t • 1 1 I 1 • • t • · • 1 t r 1 , I It • 1;, ti•l 'II':, • .tl•· • •I 11•• 11j• I•'• .t t j)tf tr !!1 , • l :; ·~ ·~ ~ r:·! •~.' r .. •1:1 ~· •·· tfJ Jf'• •- <( z 1--en :::> CfJ , ... 0 w ..., 0 a: a. (.) -a: }- (.) w ..J w 0 a: c >-J: w > a: :::> 0 w ~ a: <( J: 0 ()) -c w ~ < ..... UJ I'() ~ er- N - w ..J ... ~ 0: w > -a: l I t I I ' I • • I , . . . I I' l • I I I I I . j~l I II I I , • , I'; •• I :! I. I II K'' ' l I I 1 I I i I ' I I ' • I . ' : ' I ' ! I , I • • l . I ' • • ! I t ' • [ ! • ! • I I ' I I , • j f ! I •' I • • 1 I , I , , , · 0 • j •-r· I j j ~ I I !1 1 l I l ! 1 ;-; t I 1 • • ; r j I ; I j ! ! ! ! 1 i ! I· 1 f t r\; ; f I I j f I i I l ~-. 1 I , ' t I 1 f ( • • l • ~ • • ' .. ! I I+ I t 1 j l I r '. t • 1 1 : 1 1 1 t 1 1 1 : 1 • • . 1 r 1 1 1 • 1 t i • t 1 I ! • • ! t 1 • I l I 1 ~ • · • · -t • • ! · • • ! 1 ·f ~··r • I '!' 11 1 1 ~ji, .,,. 1·•1! • lli•· 1, •• t'!i .r,: li .• ~~~~ 1~,. •t~ •··i ••1-! :.,.;; I I I I I i I I I l I • I i t I I . I i i • I ! I I I • • I 1 I f I I I i l i I ! l I I • . • I l t t I t l ' ~ ·t t . f 1 ~ 1 'j • , , I , l : , • • • , •• 'J 1 , , • ·--r: , , . # ~ 1 , I ~ . t-• I ' ' ! f J 1 ' ~ I f t f ~ I f • t ! .,. J 1 ~ : t r 1 • \ t ; • ' I ! I ! : • t ! .. t .;-• 1 • .-• t , • , "· f -t !' ,., • f ! t l i I t 1 I I I I ; t ( t t 1 ! l' t l t ! t I I 1 " f t t ! + >-' t l ., 1 • 1 " J ~ t t Y r 1 1 ! i • T T f • .. • t 1 f' t' 1 • ! .... '"i ' ' I Lt 0 0 0 .. 0 C) 0 0 ~0 ... 0 ., 0 0 0 .. 0 ~ 0 _o 0 .. 0 l') 0 1.1. ·j· ... r·. : _, .. !.· r .. _ .. l .. ; . . : T' t"· ~--· +•-t • ., , ,. :.. t-1· •· T ·-· •• • + T ,. ;.t~ ,-.1 + 1 i··· ·-~ R"'·-t -t~ ·· .... ;...~-t-. + .... ~ -. ---+-1-r-..--r-!-.....,.....L....,...,. . .;.. ~-... --· ff«t f•tf :'·· :·· If!• 0 ,.-..-..-f-ffJ-t f~tl -t•tt f *' t+tf "!f 1-t-ti •tft Yltf 11<~•-rl.,t-t~ ... I I t f • f ! I .. ! t t f f • • l t I .. • • , ' I .. 1' • t f , ,, ' t • f •• ! ' t t ' t t t .-t t t , t • " .,. -t ,.. t • • i .. ; ., T t t ... _,. -... ~ "" c z 0 0 w UJ a: w 0.. 1-w w U.,, t:) -m ::) 0 -'j. I j i t:• '• T . ' ...... ...._ 1-• • ,...,-: ! ; . ' . ' • . • I f : ! ,,., I l I ! I r l I I 1 I ~ i : 1 • : ! ~ ! • ' l I ~ t t ! : • t I I J I • 1 . I 1 I ;\ I ! ~ ' ! t ! T I T I • • I • ' 1 .. 1 r. . t· r ~· ~ I . ~ l I f t • l I I ' r I I I ~ ~ T 1 t I t l • .. l I ' J t ·I ~ • ,_ .. ~ * I t ' • f l • t t ' ' ' ' + r. .. -j • -t f. t " ! • f· ' t + T -r' ~ .. ~ I .• • . 0 ,. · r·, ., · 1 · • · .... • t t 1 " f t • ~ \ ~ t • 1 i t • t t t t I 1 1-t ·t r t • ' ' t -t " ' • f t t r f ' t -t ,. ~ • 'f , 1 • i t t , il +-~ ~ ~ t -• AI < •' ' I ' I · I '' "~~~ 0 '•. I .... 'g f;w l ·.a: ::l .... z w > . . . r·· ' . 1 • ' • • • • • 1 • ' • ' • • I I I • I ' , • • • • I I ' • t • • • • • r I ' ; I t I I t • • • , • t t 1 .1 i . ' ·...-r.:-!· r·t~"·.·t· ..,..r-r-t·f-'·r _, .. ~ ............ r ··•·-"·· ~ ... ? • ....,_ ·r..,..-t__, .... -rr-;"'""' '"" ........... -t-'T" .. .,..--..~-T"f-T-:~ -,--, ...... ~ ""-r-r-;..-._ .. ·t--T.,.-.. ...._...,--r .. -~~r·r,--+ ..... T-····e~ I J ! t 1 1 ~ t ' ~ t f J • I r * I r • r r • t .. ' ~ ... r • ~ f 1 • ~ f ! t 1 t + t • ! • t • .,. -t • l-t -t t r t • .,._ • ..-t • ..-,r: o I , I , -1; I l r l ·• . I I I I' I ; I I • I • I • ! I • ' • I I I ·t I ' t • I • t I 1 • I ' • I . t ' • I • ' ' .• • • t t • • ~-• + t • • • • -'-l I ~ • ~ ·• ~~~ r> • • I I : • : I I I I I I f • ' • • ' ' • ' I 1 ' t j I I • • • t i I • I I ; ' I I i T ' I t • r . . . ! ' • r t • • • • .. • t . . ' ' 0 ¥1 '• • . f 'I . , 0 -z t·:·~:··· •. .... ... .. ··tt··· .................. ~~ ........ ··t· 0 - t ! l l t t 1 ' l I I ' t : t f ~ l t • • .. t • ... t t· t • ' • t ,, ... ., • t t • t • • t ~ i ... t ' t 1 ....... ..-'t ..... K" . + • ... • t " .. ~ • • • .. C!.. 0 f I 1 r• t • t I t • t I t 1 • ' • r t • t •-~ + • t • • • • • • .-t • • • ' 1 t t l 1 ~ .,. t-• .. ,.. ; .,. • • • • • T .-0 ..., t 1 J i t"'" t l l i f t I t f t ~ ' f f f f t • • t t ._ • • .:. t t • t " ".. t ' t t t t • • -t ,. ,.... • • • • f , • 1-~..-... ··!· , . 0 f J t • • t t r. '. • t t * f t t 1 t • t • 1 • ' • ~ t r ...-t. t r • \-• ' ' t-• • • ... , .-" .. , • ~ ~ 1!:: r ... *' .. _. t t ' 1 ' "1 ·+ 1 -t ·j 'I' -i··r•'t'"l' T'' l I' 'l·t--·• rr--I !·..--·-r +"·r-t-·~ ... "t ..-.-....-~·-,._ .,.,_, '"'f.--r-.-· "'; ,. r •-•-.,. • .. ..,..~.,. + •' ',_ •' •• 10 ~ 11 I r I f f I lj I ' ' • I • • I • • I I • I • • • • • 1 ' • t • I ' 1 • ' • I I • • f 't ~ t I' I t ~~ • ;~.....: • T • ~ ; 1 I 1 l , 1 1 1 1 ! . ! . . . . . , . , 1 : , , ~ ~ , r ~ ! . • : , • , ~ ! ! . 1 1 ; :· j. • • t : i , l ~ • ; 1 i r-. . ..... 0 I I''' 1'*1 ttl I:• !~·t• t•t•l;-111 t. !!t• Jt•• tl'f , ... , t•tt 't~-f~ ~-··! < o f j • • ' ' ~ • I 1' J ~ ' • t l • 1 i • \,. :~ r 1 · ;·· ,, t , · - • 1 ••. 1 ,_, · ·. o . · u.. I .. I .A" "-L c"-l C:) CX'\ (.,l • • . ""' --1 ---i:J Q <::J ·al r·) rn N --.._9 '~ .....9 .........g ._g. ~ $31 a: ,._s 13A31 V3S NV3W '3A08\f ..1.33.:1 'NOI.l VA313 __, -..9 U) ~ ~~::'-~ ~· ii?:3 ~--.. '1 ~ ~ ~~!ii ~· -\'!<!".f ~'I'\~ ~-·~~~ g. ~~ ~a llc-"-?"-t,·~ ~ in'=--.:-;t:->W-'~"1 ~ ""'' ......... IBiE'i t4r~:.f-':'t ~ ....,... ~"ff."'..1J1 l ~::1 ,..~,J-~·«:±'I- £!11El ''""'"':."'¢ -~:-,·-r ~· ~9 ., ·.,-_"*"~ ~ ~-~-~:::::·::;:~ .. :~:~;,;::-..... ~~~~";,; t:=_!.'j .. '";.~~~:-:-~··::-· r;.;:;::::~~--~·:·~-:::~::;;..;-::::':"~~·:::eit'\':3'~~:=~~:::::.::~=:.:.::.-:::~---.. F::::~~==·~;··· ~~.-::;-=:~~-:-~ -- I'~ . ~ J " . -'-~~ ..J w > 1!115\ -- ~ L,L~- < w u;; z < ~ LDLL- w > 0 m <C f-w w LL. .. z 0 l.LJ-;TI- i= l.o\!\- < > w ..J w lo\2 0 . ---:-------: · -·---j ---: -_=r--= --i ------! -·--+ ~.n, n..·lT 401 "T -------.---"-~-~-------f 1-...,N:lUJ \ I ----. ~-: ----~-.. ------t'------y------+----·-----·+·· . ----; --~..,.. .!...-.... ~----~------· ·-----~"!-"~-----t --~~---·--~·-·. I -·- __ .....~.. t .. -. "" ..!.... -.. _._-: .. ------=--'-:-·-~-... r--------r-...... --~ ·:.J .. ----: -~ _. ---------.---; ! .• ___!_~+----.... -...... _ .. _.....:. ... f .. ...:. __ ._ t----or ' ~---·-----~ -· ~ --.. -~ •• ----'.....!..-----1-~---..: -· --· ·----------~-------·--··--·-r-· -----! -.. .. . - --+-·-. -" ........ ..oe -----·-· ... ...; I ---·---,!· =t:l --· --: -___ ... ---·----,·------' ·-------.. c . ---,-------.; --------r------7-----·"-r -·- ____ , __ -·-------f -·--·-------;-•. --·-·-----..,.---• -•. ! 1 -~--~~:J1_-_·~------~-----_-_-~+_·-----·-·-t---· ____ -~1_-_··_-_--_-_·-t··_-_-__ -__ -~_._--_·_-_-_-_-_·t·------.-------r-----·--·-·-- ---·l·-·----·-·-'-1-------;------:----- ·--·...J---------; 1-----r---·-t·· --------·-·--r--____ _! •• -·-_ .. ---. ~ ---1--. -· .. ____ .. -----: ----·--··----·; -----···-;--. ' "' -__,.___. _,. --·---.. ----1- ----·-· J .. I ' .. ------··-4·-- ~-------·----------·-+-----·-----~ --.. --. .. -------~-.. ·-----_ _;: _______ -------~ ----·-' • .;. -1·-----i ·-· . --r----• ..:... .. -------~-i--. ---·-·-----~·----~-·--+----------+------1.-----+-----.~------------,-----· -.-t_----~ ------·---··---... -... -------· j . 1 ----------------l -.• '---4-------· -·. ------- 1 -.. ...;. --~-~r------;---·--· ----... . ·l --. --- . ! -i - --l --J l-.. __ --. ~ ~--.... ....... --.... --- ' . ··-·--·+---... --r-- •. --l .. ·--·· ~­ l ... -,--- : ..... '.:;</. -----"1 -• --/ i"-~----------~--------------~-------:=~---_-_-__ ~--------.-----~---_-__ -_-_-_-T-.~---·-__ -_~! ~---.~_~-r---·-----:--.----·-- 1 ··-1 I £. •• -·-···-- . -. 1 --'1 ____ ,, -..J..·--;--·-_.,_ .. ___ .... ~-· --------·· ..... ' -··. --l -..• ....: ··-·-• V:·· .. ; • .. --• ---.. -_i ~--.:-=~--· --''-" . ----. ---· . 1--· ---L_ . I -... '1 ... . . :·.:-~ ~ ~ ·-i- ~ -J -- • 1 --- -· f - -1 - -1 ---l . • .• --+ • - I - _ ...... "" ·t - I -, .... . .. --··--,J.. -----"" ~ .... - ·-· ---. .. v .~..... . . . ~ . -·-· -----··· ·i ~-z -~· ~~-~ ~~ -----:~: = ~ =~-- . ' ~ 1 - -1 .... , ---··--..... ~ -. ·-·. ·---. , ___ ·----....... -· ---... _,...., .. *. ----.. ----.. .. .. --- ·----! •••• -----· ------l·---·-----. ...:....,._, ___ --··--' ....... J.. .... -·-----·---1---··-----4---··-·-· --- . ~ ·----.l , j /ij''----------· -· ---... _. ____ ,..,.. --·--_; -.... -- 1 --r-----t-1----r--v-/--,...-+--1 --r_ . -__ .J --.. ------~ -·---·--\J-f.\.{1:-R:.l~ ~ll~ fJ ~ -l v:----J ·---·-. 4 --·--· :-··----~ -------__;.:._ ':'-'.~......~\.:---:-··--; ., ~ -·---· ~--·--·-.-"·----~. --·----· .... -i . . ! ' ' -J. .. . . " .. + --+ ~ -~ • ----.J --. . . , - j -it ' 1 --~ ·-1. _____ _ -"""~~"-1 t : •• t .. ... ,. .. . ... ---r-' -"'Iii.-== ~ ~ . . -~ t .. ~ . ----t ; --. ---. i • • ~ -• I f -• • • . "'t -• • --•· ---~ l ! ... ,. ! • -! ...... ~ .-... ---~-- --. • j -·--.-- -- . ----- -·-.. ---· ~ -1·--. --l . -------r--·:- .. ---- SUSITNA HYDROELECTRIC PROJECT ---·.., -..,..., + --........- . • . . . ' ' -~----~-----------,.:. -----, . j --~ -. ...:. STAGE DISCHARGE CURVE ; ,; I l 10,000 ' 20,000 l 30,000 RIVER MILE I ·41f.O,OOO I 50,000 D!SCHARGE, CUBIC FEET PER SECOND 60,000 HARZA EBASCO JOINT VENTUR~ OCT 1983 1 f.o2~.- ...1 w > ~~24- < w (,/) z <, ....... ~ iD2 L- w > 0 m <'7)·-..,_ (JJ :-· w w u.. ... z o. ·s t= l.ol - < > w _, w &12 0 _ ~ ~ ~-1-~= J :_.:. :...-: .:-.: ==-r.: -~ 1 _ -=--=~ . ~-~ ~ ~~ ._: ~ .:.!-::1t\\2>TI 5 ' . J . -----~--t--.------·. --------~---' _____ .... -. -----~ .. --:~-~ -~=: --=-~.: -==-~1~~~-: ·-----~----l____. ___ -------·----___ .:.., __ ~ .... -.--t--.. -. • I • ~-----+----·-~ ------+-------.----- ---4. • --• ....&. -. • ~--~----:-. --,.. -· ~---------··-+- - -T·-! ... -.--~--""'t"'" ,. -------t"',--.....,-... -----.,...,_ -~...,_,·--r~ ...... _.....:.__ ~ ·~ ----~ ·-... -T" ~-4----t------;-------! -· -.. .... --.. ~ . .., .. --... ..;. '0----·--.... -.. * ..,-~---------·~----~ -·-.. ·----,__,__·-~--+- . --'1 . -· . - -,. ,. __ ..... --. -... ...,. .. ~ , I ' I ____ J. -·-·-i ----l-------. __ .! _______ --;-----1·-···... . . ...., -------i-----· ---t · --·-r-·-· -·-·-·-----;---...!.------··-----l 1 · -_J -J-• • __..., __ -·· ·--· • -·---· -·•·--··1 • : J. • I •• • . -=-=-~ i+::--~ ~-=--= = + ~-~-=-~ =~p--~------.. _R6 __ _. __ • -_ ~ ---__ .J .. :__:__(_ __ ~ ----~~ ---~-----. ----~ . -. ---·-1 -. --~--· ---i -------..;. ---f - ----~ ---~ . . . . ~ -=--=--=: ~ -~--: = . _: :_-=-_ -_ ~ : :~ =-=T~ : ~--:~.-= -~-~~~-L~-~~-=·:·~~ ~~--~-:--~_L ~ ·:_ -~--~ /. ~ · : . ~ .. _ ----..J -.. . • • • I -/ .. -----·-------~-··•-i . ------.--.. ·----, --------~. . . -· .. ----~ : ~ .:.. : . . ---' . -=---~-= :...: .... -.--= ~ =·i-·--~-=·::-.:.~ -=~=-1#---~· : . : ~----: : ! -~ =· ~ .· ~ . --... --. : - ---. --; - . j . --. --. --1 . . -. . . . . -. . . ----I j7:[' ------1!-----;-· ··-·---- . --. -. l . - ··-· ···---··-t···-··-----···j --·; ... ---··t····· ··: ~ ·=--~ ~--~-: +--~: :J_--_ ==~ --:.-. : -: -:_ ~ ~ ~ ~ ~--: . . ------.. -·-·---"1 -----. .-.. ---. --t I ---•• ---.J ----·-----•••. ' I .. .. ... .,... .. .. ,.. .., .. ~• ... -._ ,. .. t !I ··!· • ~--·----1--·· ... _.: __ r_ -~---··--· -. ! .... , ... -~ -=-=-.:...:-=-=-~ . -t --. -.:~=-=-~ r-=.--=-~----~ __ · _· _· ~--'--=-~ = · • ··--T . = : : : 1 ~ ~ : -::-.: : : ."~ ... ~ ~ _: ~: = .. -: :._: =: : _: _:.: : : -=._-:__-~ : : · ~ : · j . . . . . . - . ---, :--::t .. --. --· .. --i . -• . . - . ...• . .. ·--. . -• . ~ ---~-... .. ---····· --~--~--~ ... ~ --····-----······-· -·-·-· -. --. • • • T • '. • • • --• l _, • --/ • . ~ -~--• • • • • •..;. • • • .. ~ • • • • ! • ~ . • • -····. 11-z·-...... J._..: ___ -· ~-....... · .• • • . • • .. -·1--, .. " •• ~ 1 ... + - • --' -.• • -• -• .• .j. • • • 1 -----· --. • ·-• • • . • • i t t .. _ .. ! ......... -.-. . . . . . --. .,. --' . . . -; -. -. -;-..--+------i--,Y.--• I 1----~-----·- . i = --. = =-x-.. t -. ~ : : : ~ ~ i ~ =-~ := -~ ~ --~: : = ~-~ -j -. " ~ ~ • -... -..... - -..... -.. -""' .. ,_J., ~ -.. -~ '! ~ . . I __ ~ •• --· • . -. • -· 1 .. 1 .. : ... 1 ..... ~ .. 1 .... ~· ..... < --... ---: --·-·-·---· -~ I I _ _: _::__.:. ~ ........ : ·---... -.. _ ... ..,...,._ ~-.... J-... ··--... ~ ··---·-""-·-..... .. ..... • .• _.,. __ ..... _ .. .,. I ... l --. " -.1.----~ • -----·----• . ---. 1 -• -• ... - -; · .... .. _., .. r ..... --~-------·; .... ----· ·-----" .. 1 ... ... ... .. ~ .. -• . . • ' -. -.,. . -1 • . t -·------. -----... ----------: . ·-1-·---·-,_ ---.. ---,F----~+,___..~ _ _,..- : ~~~~1 • , ! .. ~~ ~ ... ,. ~ --. T .,. .., • ~ -----•• -j------· -- ., .; ... ~ "' • 't - ' ........ f + ... "'-~ ~ .... • i : ---... t-....... . --. . -··1· ...... . ' .. .. .... ... .... .. 41 ........ i- • • -. j -• "'"' .,.-· ...... , .. .. • ... -.. ; ~ .. • ""'!' ... .. .. .. .... ., ~ "' ... ·--<~ ..._ ~ • .. ... ..... J ... ., • .. -... t .... ---~~-----~-----~·----~ .... .._ t i .... . ' ----1 -•·. 1 . . 'fl .. • ~ .. ~ ... " . ' "' • ~ ; .. -4 .. : I . • .. ., t•~·l--~ .. .... ~ ..,.._ .. .... f , .... ~ '*' -I -•.. '1. • • ,.. ... "' ~ ~ .. ... .. .... i . . .. . .. .... .... .,. -.. ~ ...,... .., ,.. f ... ·t .""" + ..._ .. • I . ~ 1 " ..... ., 1' .. " ... " ! ....... I . -. ·-i ! SUSITNA HYDROELECTRlC PROJECT STAGE DIS_CHARGE CURVE LRX-3f.o RIVER MILE 13/.Jg I 20,000 30,000 ' •40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND lll:r·---------------------------~-----t!'-------'""!11"-----.... HARZA EBASCO JOINT VENTURE OCT 1983 ~,, .. ' ( ; '· '' '·' ·~.·.· .. ·. I,, I ) .i · .. '-'.· ·.· ';, l ~; 'i·.,_.· J ' ' ' t " 1 &35- _J w > w 034-...I < w UJ z < w (-37_-~ w > 0 m < • ""1 \ .... . :_cju- w w 1.1.. .. z 0 nB r=~L - < > w ....1 w ([J2to- 024- &>22 0 -' --~-~ _· _-_-___ -'1 -------------.,_. ___ ..... -;·-·· i . : . ~\\0..\'f 5\ -·--~ r·····--------·---:--·-! .,.---· ·~----·-t ,.._ .. ----l.L:ATUU -: ·-·--··--.. :-.-~ ~ . ·•-·-··· -~ ·------r-----{-----· .... -.. ----__ ._., ........... ---... -......... -__ .. __ -·-_______ .,_ ·------;----.. -·~-........ ·- -----.-. --~-~·-----,r-T""-'·--. --1--------+----i--.-----+---·-T----t---·- .... -·-"'"' -" -----.,. ... ...,.---... ~--t--r··---...... ·-------:------......,..--......... ,_,_.~ ...... ~---~-­ • '--.·-~ ---~-f-~. ---.---~-1------r-;----· . ----·-.. ·-.. -~ 1---~· .._. .. --'T~_ ..... _ -.. __,....,-, ·----r'----1· ,. ··---. 't .. .. --•• -----------~-:-~ ----t-· ----""' ·-·-i ·--·-·• i -----· -.. -------~ --• . ______ _j_ ______ ··----~ 1' ---4-------t"· --------· ---~-+------·---__ j _____ -----+·. . ·-·- • 'T ---J - -.... -·· + -"' ... --·-. -. -·---t-.. ___ .,.--~--' -··· ; -----' ~---·-----.. ; ... .. . -· w ... ·------~~--------4~·--_·_-_-__ +~----~-----_·_-_--4t_-_··_-_-__ --+------·---~r.--------·--·~·r·-------~--·~··--------_-+Jf--·----t. I ..L • -+ ·---... ·---··_] l . ·==·.-: ;::·:. --·-·--; :·~ =-=--~·~-~-~~~~~,~~~=.~-~-~~---~~ ·--------=-~--. ~~·j·~ ~: ~ l '--~----~-·r~ · i --·-------·--. --........ _ ...... ... ·--+- ' .. : ==-~~-: ~. : _~:·~ ···----.j, - . . --. .. -.. ' ! -.•• i. -.. -... : ' . . . . -·-- ---~-------·---------------+------~------~--------------;-----·------4-----·-: : J~ -~ . ~ --·· .. -. ~-.. _ .... ___ -t -I ···-+-.. --i·, --· =+~---~-~, ~-. . I . ~ --·-. --'--• -·----·"1· • --• -i . .. _ _;_ __ -+-·---t'---+--~---1---------j[--------;------r-· -----·-~ -----t-----!-. --~ ~ --·-· . 1· i· + + -t • t- . ----·...;..----1-_..____.,.. ___ . __ t . T • . + ' -... i + ... I • -t • -. .,. - =-1· . , - • , . . ... . ·-::· ... -~v. ----. .. l . . J .. .. .. 1 • ~ "" .. -... 1 . 1 .... . ; . ~ -.. .... • j . • ••. • -J ... ·-.............. 1 ~ ·t i I 1 . .. -l . • • -t·-- ~ -. ~ ....... i ,.._ ... ........ 1 • ,.__,._! l • 1 • • • 1 t - .J • t ..... "! .. 1 '~ .......... o.4 .j=£:~ ·-:-':.~~---. :.y~·=-~.: .+. t . . ----· -=---~-· ·~ .. _.. ·• . ' ---.. -·--.- . ~ .-: ~ -: .. : = -1-= :::-. =~:r: :.=.-:~ -: =~--~ -. • ----.. . -. -·-' . . . . . '1' . ! -.4~-:-----· ... -...... ., ...... ... -.. --·.-----l--___ J_ ---. ---!.·---+--j ---T- ,. ·~-t .. -~ -" ... 4.. ... ... -t -i-- ' ·• • 1 --· • ---• --i ---1 .•.••.• :. --+--_____,· • ---.. ~-ri .. --=_--:-. __ .. ~· ' - . . . ---.. -.. r . -. .. _ 1 . -·-' • -•· -.1 • --_ _... ·~ -----·--.. _, -· - - --!-----"f---·-,. -----· -~. j __ -----· I t .... 't'-~ ,. -: . ·t ... -r -~ . ,. . --.......... '{ . .. • <4 J' J -. 1 .. 't'"·--, •. ' ·+,. ~ . . I -·1 l SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LRX-37 RIVER MILE :31. 8~) T 10,000 l 20,000 I 30,000 I '40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO tJOINT VENTURE r!' \ : f,' UJJ ~;. i .. •' &45- ~4(o .- ..J w > w 4. _. {r, it- < w f/) z < ,. w 11 1-~ ,('1__. w > 0 m < //1 ,_ 1-J:""l .1 w w IJ.. "' z 0 i=.;33-< > w -I w tt34- 0 I ·--·1-----. 1 • -----j ---... ---. _. ... ----- ---t--- . . -----1-....• - i ··----. .. ·-.... --.. ~ . . -·---... ~ --·-· -- . --r--. -• .,_. ,. ~-..j ~ -·~---,.. . .,. '"'--t-. ·-.. ·---, ____ • ~.:..-... ~ ----~ •·---...... L " ; .. ---..... -· .. . -. . -· . --. .:. ----. -.;. .. . .. .. .., ..... - -~----t-·----r --+----··-'----·· -1 ... ~-_, .. -~ ~ :.1 : . ~ : ·t . ~ -] ·_~-=~.f.~ : ~ ~ ~ ~-~ ---~ :, ~~--~-~-:-=-~~--=-~ ,.--=-=--~ : ---.. . 1 --. i . . 1 . . . ---. - -' .... . --t ---. . --t-. .. -. . ' .. ----. ---.. -~ ~ ·t . -~--......... -......... --.J - -......... ·t ... ----~ .... ·~ ----_, il ... . i .j .. -. . -. . . -.. -~ ~ -.. --)0--· ----~ ---. . ~, ; . ·• .• .:.. -·--·-·-----···----. -. ··1 •.. . --i . . .. ---1 ~ : = = . -. ·-.. ! ·-... -· -1 • . . ····r···· ----·~·-····-.... --~---·· ··-, ..... . ~---· . ·-... ~ . . . .. . ·•· ·-.. ; .. --.. l ...... . ... . = :/.= . : : ~ . : : : 4 = ~ ,. .. -1 • • -· , ... ... ... ~ -.. -<1 ... . .. . .. . . . . -.. .. . ... -. ... ~ I '"I" .... -1 ~ .. . . , I · · · • I .. ... -... .. ~ "" ~ .... "1 -•. . ........... -...... -t--1 ' .... 1 . ~ _.. ·-,. .., I • -·-, . ~ -. . ··t ... . . ·--. -,. --.... SUSITNA HYDROELECTRlC PROJECT . -. . i ..... - . '-· -i . -; . STAGE DISCHARGE CURVE -. ~ . ~ . .. . ~--·j··~·.;_ • .. .. ... .. .. • • .. "! ...... .,. ... ... .. ,. • 4 • _. .,. • .... '!' ~ ...... T '1 • ..,. .. .. ~ "'. .. '""! -- .... - - - 1 'T ....... ' ,., <t • • -t -: <' .. .,..... ... ----, -T"-,.--.~ __.__,..._---'--+-' 1 •. ~ .. +: .. .-.. ..... ... • "' .. -. • -'f' -.... '""""" ' .. ! ..;.., ....: ··-.. ~ t .... ~ ..... ~ ~· ..... + .... -4 .. ..t t .. "1 ;. .. ~ 'T ... ,. T 10,000 t • 1 "" .; . .. ! ....... - T 20,000 I 30,000 RIVER MILE 132~7 I '40,000 ' 50,000 DISCHARGE, ·CUBIC FEET PER SECOND 80,000 HARZA EBASCO JOINT VENTURE P---------------~~-----------------------~------------------------~ ...J w > ~ ioS<?J- ..: w f/) z < w /,..hi,_ ~ lL'vl.O w > 0 m <( .... UJ w LL. .. z 0 i:: ·. 52-r-.u; < > w _, w 0 ' · ·:_:"=--~s=-=--1 ~ _ =·=-=·j·= ~--=-.:.:..t . ..:..~_:_:_ ~l\t\¥JIT 53 ---,.----+ . --_.,__ . ... -----~ --.----·--·-+-~--. ·--·-;----·-----'· . .. ·---.. ~----• -------~--. ----··----,_._l ___ ------·------~---;··-• -----• . • • --..-.----t-----.-"T"··· ·---· . ' . ---.. -.. ----_ _. .. ~---. ·---4--·~-.... -·--------,..--...... i --··-. ---1··· • -... -----~ ""':'' l • "T-'...,...._..... ---------r-:----.,-1 -~--·-:-" .. -t--·- ---·-···-. ---. ·------. -·-,.-7-·--·~1--;-......... --.,---..,.--·; ....... ·-. --·-.. .,.. ___ •• .. ·~-----.. .... ----""'"··-------· --·..,...~-:-_____ ,. __ ,_ __ ----~ 1 .. - ----i -:.=.=-1~---·-r-··-----·---··-----r----·~-~---------t: .··-:·:· .. -' ~ -·-·-j· ... ---l, ____ ---·-----+---. --·-J . -+;--.. 1 ·-_··-----~~---------+-=-__ -_:_~1"· ___ ._-. J -"~.-~-~~-=--= ~ . -4--~-·-. ----~ • . • ---~--~-=- --+----==:-=~·-=··==2-=~---=-j·:=~-~-=--~--=--=· ·= .:.:::-...::.'1.~ -... --. ---"-1-.... .._ -.. ~ ---... -----···-·--__ j .. ·-.... -·--· ·----1 . . --~-=-=~.----.. : --· ·-.---:-·····-·---·--. ~-----·_i--···---···~-- ·--. ···--,.----- 1 ----... - ----+-----··~-------- i 4 .. • f -·i I -i I -. - + -- -- - ----r-~-t-l ---.. ··;t : .. t --. -_-:·: : :--=t-i---J . - . " ~-. --~j •• --·--~-~-----+----~---~--+~---_---+-_-_-_-~---~-.-:-i.-=--=---5--C· ~--~ ·_:.----~:. ·:·:- ... 1:"-... ,.4 ""'t --·4-"'---•-•-.... u-.-,_. .. ~. •• ..-• ' - .... ,.. ....... ~ _,__ -'"""'t'----" ---··· --;-_.- .• -·-t 1 --.............. _-... .• -.. ·+-- i - -----j . -·--j·-··-·:···-.... ...... 1 .......... ~-··-.. --·---~-· ' -.. --+·--. -. --.•. ·-·--t-----.. ¥·----· -~ -~ ~ l-:-.-.-.. -4.· -------1~:-----+-~--+-_:-_. :::::.:::~;~---.-= -. -:.-+· ------r----------·-·-·- .. ~ ... . ., ...; • ~-...J ' - . -.. -~ "t ~ ........ -~-·-... -·-• i " ..,_ 1 i-t ·--. . . ~ ... -·, .... ·• ..... ·--.... i· - I . 1 . I i -' . -+ .. -.. ~ 1 . ~ --r..,. -. L: -...:.--.4 ... -... j -. . . : ; 1., ; 1 .. : ·~ -·--. 4 • ~ .: - ~~~--4-------~~-+-r~~------~----~ ' ... + --.. . .. l ... - ,;. .;, .... 1 1 ... t ... ·-t ! ~ •· •-t. T --.-· ... 4 .:. .... B """' ' \ SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE RIVER MILE 133.5 I 10,000 ' 20,000 30,000 I '40,000 I 50,000 80,000 .. DIS~~~~A~GE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE -OCT 1983 r.·~, l H ~ LlJ ''] i 1 l:' '' "'" .. '~.;,. I; ' ,11 I.D~4- _. w > ~ ~iDL.- < w :4) z < Wf.a(J)- ~ w > 0 m <~s~­t-w w LL. .. z 0 ;::: la6fo- < > w _. w Ca52...- 0 J ----. -------:---. ., . -.-------·! ·--~' .n\'O..rr ~ "' • ... • -• .. 1 f I ~ I ,{1 ._{,)_' \ ·--""---~ -----J--~ I --·-··•• -........ ----·-··----; ---·--·-: • . ----i·---_;-----~-..__ -1----· I ---I ---·----i-.... ---.. . I • ' o ' -'---J... _ _: -----------·•--..,.---·--·-•-•--•---•-••0.•••4 -..._ .. _.,.. .,....-. 4 -~ • • J ~ I • • ~ ' l . ..:.-~ - _ .. .: ~ .... !. ~-=-=--------. ----~---=t-.-. -----:--. ; - __ __.. ' . 1 ____,_ ---· .,_____,___:... __ ---·-~ -------·~ .. .,. • - --...,.--T-" - • -t - --·-• -• .. -• .;~-....!. 4 .,__!_ --.-.... .. -_._._2 _ ......_1------------~ • ~-·~ I ---1 . ___ _: _____ ; .. .:.,_ ______ -.--....:...~ ------·1-·-----...! ··-r· .•.. -____ .... --- ---.l -· ------·-i --·1--.. --~---·-----:.·-·-·1-·-· ___ ;_~--~ --·±--··~ ·-· .. .! 1' ., ----~--_:.. === i· ~-----~.--:.: ~----=-~ ·==· . .::-.: .. --=--==~1---~-~·.-=--t.· •· ... -.. ,;. ____ J ----·-. -·---+ --------·i---·------:-----1----·--·t ···-· ~ __ _._ __ 4---~-·--~--+---+--=-----t-·--,,---T----;----- ... ----! ----------L-------1------.. --·· ·: . , --··· . . .. . - . ----~ --·----.... ---.: I _ __. __ --: ---... . I I • -i i . 1 • ---1 I --. 1 - ----1 I • -· ---. • .. ---+ ···----·--r-----· ------·--- :_:.= :-1 ~~:-~= ~=-=---=-:~-=--: .:-=: ~ ::-=.-=·:-= . ·---I --· --·--1 --- .,. ~ - - I -·--· .. ' • 1- -~ --· ..... --... -· J l ... __ ..J -----i -.. . • ---! -.. , ·: ~-----~ j ·-···-·=-~=-~-~--=------::::-:·-:~:-::·~-::: :j-:-·~~Q(Y;~~\F~ ~ ~-1 __ J·--··--··----~-----·-----·=--:.'_··:·~-j·-·-· :~.: ~_-t·:·~.-~ -·• .. --+ ------·---.. ----~ t-. -~--- -~·-i -t;./. 1 1 -. • - -...: --! +-·-----~ ~ ----.. -~ . j . -. -:-= ~ .. : -. --~ ~ 'f" -. '1 .. -;. :-~ ---; ..... ·-'1 J , • - -• -"'! -~· '"" - -... .. -----.... -• 1 . --~ ----. -/ ... -. III•••IJ···············fll•••• --.. 1/· ' -~ -4 .. ----t--·- , -· . I ---,·-.-.--: , ~ .... ·-.., ...... .._ __ .... .. -.. --. J : " .. .;. ~l ...__!~ . .! -.. ' . j .. __! ~- .. _ _,,. .. --! t 10,000 . -·---~--"·r " 4 ... --....... _ .; ..... -• • I i ~ -;__ -+---. ' .. : SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LR.::>\-~ ~ RIVER MILE l 30,000 I '40,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 i I I ~ i. I, If ,,; _, w > / / .. i- lOi.L'I· W . n ...J ;r,;r. - "'~ '""""".-- c : : :.1: : : ~: 1 ~ : : ==-:=-=: 3.::.-~~ i ____ : :::-=--:-: : : ~i -: :.:~t:-~1\\ ~fT s:, . -=-=-=~~ ~= -=·-.:.~. -·~---. -~---!'" ·-·----< ·----·-· --·· -; - -. I -. --~ . ---•..• -.. ---.. ----·-· --~---4-··-----·· ---··----·--·;··.--I . -. ~~~.: : ~ ~ ~ ~ ~ -~~=-~ i : -~~~: ~~ -~~-:~ ~~~-~ ~~~~-~ -~ :~:~:. -~ ~~-~~ T ~ ~ ~ l = -~ ~ : • :·:=~ J : : : : :.~ :-: ; : : ~ J:: -: :_:_ ::~= ~ :~:_,: :; =.:: =-=--_:: ~-:~:: . l ' -·--·-~ . - - . .. ---+ -_:_ -.j=:::: L -_:__:__----i ----. ::.----. ---~ J ----, --- -:_ ___ .. ·---. -. ----. ~ . ·--. -. -· ..... . -i ·-· --. ~ --· --·-·-1 . ----... -- -1 . ----. ---.. ----. ----. . -.; ---j ----. . ---1 --·-·-' --l -. . . ---. --. ~ ' ---r·· ' -. ---·. -·---. -. . -J --.. ~ . ~ ~-; ~-: ~ i ~-: ~ : : . : ~ ;_t: : ~ ~-~~ ; = ~1-: ; -: ~ -. : : : ( ~~~ ·: ~ : j: ---,. -J . ' =i ---. -i--. --"1 . --.. . -~-~ :.J : ~-' ~ ,--~~~~ -::-~ 1 : . ~ = ~ = : .: -~ j·:·· -=~~ -· ~ -~:1· ~--= ~ ~ -~~~ -~--: . -· --~ • • . . . . ~ . • • . . -. : • -• - T ----• • . _/"' 1 • - • --"1 • • • ] -• ! .. - - . --. . < ~ --• • '] --·----• • • • ~ 1 --' i . I --J-::;:. I · --· • · · · · · · · ~ · --· 1 -· · · ~ ------t · · -·-~ ~--A. ·· · · · r · ~ : ~ · ~ :=_:!: < ~-~::: ~-E1-_;:~;:H>>?-:t· I:_~:~~. :--=r' --~ ---~: ~:~ z .. -~ ! .. ;. + - - -~ "" ! -~ ... .. .. .... - -... ----"'--......... .,. ---.. --· .. ... ~ ~ ... • -• ~ . • . -• •. l • -• -• • ; -• -. • ., • ---. • • . -• • j . . . . . • . <w ~ , ---.. ~ .. ... . -~ . i -..... - -----=-F -·... "" ...... ~--r .,. ..... -· • ... ...... -; . ~ 1 ... . ... . ... --·-·i·--- • o T -i • • --. • • o • • -7 -•··•• •- '" .., i-I ' • -• I . :f! Ui ..i.. 'J . -----T • -~-•• • --• 1 1 LU ~ ·: : ~ : : : : ~ : -~ : l ~ . : : ~ -v: ~ ~ : ~ ~ ~ : ·: ~ .. : . ~ : ~ . . . t ~ -. : . i . . . . . 1 • • _/ • . -.• -~ • • • • • • .; • . • • . • • • I . . • . . .. . . • ~ . ~-~ . . ·_ -srr-~ =-. ----·-•. ~ .. . . -. --~ ---. .. -. ----~ ---=---·:·- m . , --. . . : ·: ~ ; . : .: ·= . : . : J . ~ ·--= . -_ ~ .: : : -~ = ·: ·j·: ~ -~ : . - . . '1 "' 8 <j ... .... < -........ __ · .L1 _· ....._· _·_:'-+-'-,t.' ·:.__· -+~ -·---.-+-· _-_-_-_ .... r-____ ...... _--+--·_·_-_-__ -_-_-_. i!---------t-----a-tc:--5--V: { . ·• .. -. . . --... J . • • W . -•. -. ' .. - . • . --• --·, -........ -.. ·• ---·• -~ . -. ·_ 1: . . W ···:.··---~·]:·:·.: ···~ ... ! ~- • . -1 • -• -• . • -~ .• ·-t . -' . . • . . ' . 1J... ___ ,......._,.·_ --+---~----+-----+--•• -------••-" T•••---·• --t-· -t ·-----~--! . - - - 1 .. --· .. •• .... ~ -.. .. • .. ; -.. _ __,,. ... 't • ---l-· .. z 0 r- . . -. --,. --~ ·-·- ... ~ ---~---.. --' ;::. tJ) ~ fJ- c( -~~-: ....... 4 .. -----..... ---t"-.............. _._.,. '"'+ ... -..... -.• ~-.. "• .. ~.. i --------~--~~---~----~---+----.-----~--~-----~ ---i . -. l • . 1 .... - > w ...J w -. .. -.j) ... - 05) 0 ... ~ . .. . .. .... .. .. .. . --. -.. ~ -·--. -· ... - ---·t .. . • .. i . --~~.-..j. •• -•• --~ 1 . -•. • 1 ..... ---~-' . . ..... ----_...'1"' • .... ~ -"" ___ ...,..__..._,._-+---..L' ---+--~----f---,,-------1----·· -·~ _,.. ·- ~:·~i:~·- ~·14-·~· -"" .... 1 • ..... " ~ i .f .. • 1 .. .. "' ... -.. T .. '* .., .. ,. ... ..! .. l ~... • .. . ~ ... --. ~ . ... ... . • -1 ~-... .. i' . ... • .. ........ ,. ...... "" . I • -· -1 ' ! ~ .. .. -..... 1 .. .. -.. .., .. I • "' • t " ... ... ... . . -l • I . .. ... .., .., ~ 1 ~ ... ·• ... ..................... . , I .., 4 ---.... ~-_ .. _,. -··· "t .. -• T .... , • : ····+·-· ····+~·· ... ·-1 -• . .... .. ...... -~ .. "' --. --. ~ - I . 1 . -• . . . . ~ .... i ..... -~""" - ... .. 1 .. -t ~.I • .. I .. .,. '1 .;. -+ ... " .. . ~ • 1 .... -.... ..., .. SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE RIV~P. MILE J34~ 5 l 10,000 20,1.)00 I 30,000 I ·-to,ooo I 50 .. 000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE I ~ f l ([;80- ..J w > &7B.- ~ 07&>- < w U) z < ~ to74- w > 0 m ~ 072- w w lJ.. z 0 t=-(o70- < > w ...J w (p08- 0 . -.,. ... -.--' ·-· · it.~\~ IT ~t---.-----·; ..,.________ --,.._ ...: ~ l \0. ~-~~ ~= ~1 ~: -·-= ~=-=-==c.= --~ . ·-----~ -------···--t--·-------------·--·-----L--. .._ __ ---;------.._ __ 'T ~.,;. _. .. ~.__,......._....,.: ... -·----.. ~ ·-··----~·-- ------~ --~--------~--~---+--------~---------4---------·--. . ----.. .,.....,_ I . ···---·i -·-----~ ---. ·---1 ---.J -.. - -.. ·~ I ·----, -·-·.- ---;------.... --.... . -.. ---..,.. . --I . 1 . -- -1-··-·-1.----· --------- --t . --- .... -,----··-· -____ ..._..,.. __ .,._ --• -4.------·---·--------- ---------. --. --------. ---·---~·-I . 1 '" ------= ~ ~--1~:~ -----~-=-~--~~=-~-==·:~= 1 : ~~-:: ~ ....... -----' ---'-- -. - ---~----+----------+-----------f--·-----'----1-----·-l-------·---J---+ ···--····-------·-----·,-• ··-1 ·--· ~· T ..-I------......... __ ... ____ ., ____ .,._.I -. : ~i -1 • -·-;---·-+ -... --+· - 1 --4 1 .. .. - -... ~--· ~ .. _ --+ .. ' ----1. --~--.l-- ' . ~ .. ·---.. ,.. ....,., .. T·- t•• . ------------+-----------.. -· 1_"----~f-----·_--_-+ __ .-:-----_--_ --+------· ..i.---------~-1 ------ ::~.:~----~----=i -·---·---'" -~i --. . : ·-· ·t--· ~-.... ....,..,_ ~ ... ·----.,-__ ...._ _... ... -"1 ----i . • ~ ... ... .... -~ ...... __ ,_.,.__.,_ -...... """"' ~ l •.• __ J .. _....., ..,.. i -+ ...... _.. ; . ---------~ ---1 ~ = -_ 2'" ---+--~--. ---·-·· +.,. ----. ··-+ __ ..:. ··-··-·-·-t- - ·i i ' . ! • -.• • "i --__:-:-~. ·]· : . -... --. . i ~ --~ -!-.....--+----+---+----+-----+-----ll-...... --+---...:.-~---t--·------- i . 1 , - •. 1 - ' . " ---~ ! t ~ --~-~-;·: =-.. : ~ .. -._~ . ,: . --~~~ _j. ----t ~ ---------~ -· • ---• . :·: : ~ -.. __ ....... ----+---·· -,. . -.! . . -: . -. :-+--_-_-_____ _ --·· "1 . -. . ·--! -. . ---.. . . ! . . . -. ~ ----+ : -~ ·~ = -_: :. ~.:. : : : :. ·. : . -·i -~ . . --. . . -·i--. . . . . . . -.. .. . -i --·----+----+-----+-·--+---:::7""'1=----+----t--~--"i--------- 11 *--·-··-·~-. .1 ·-* ...... ~-. .oj _. ....... ~· ., .;. ... ~ _,_ --- 1 --t...-t ·_ =-. ~-.. -"" . J. .:-~ _. '1 ""' -• .,. .... 1· -.. ,...,... T'-'~' _ _.., ~----t ..• -. ·! . .,. ----·--+ __ .. ___ ··-· ···- . . . I I ~- ' J 1 • -. i I . ' .. .4.--'f .. -t . -· • .., .._ ~ T ... "' .. l - .. t • . •· ~ -. -+----. : 1 .. :. : .• -r --. .. • T--.... .. :.tl ~: : .:_ .. ~ -+-,J, '; ' ~- ... .. ·--,t-,. 'I • ... * ~ • '* i ~ -~·-i ...&. ~~--~--~----~--~~4-~'-4-f---.--... -+~~-+- • • ... 1 + ... .! + 'T ~ +· .... ,,. .~ ...... 1 ... j ... + -r .! "" "" .. ... ~ 1 ........ "' .. _ -----+·--..-.,_ ~ ~·""" ------t ..... -...,_-~ .. -~ -......... 4 --·4 -----"T 1 . 1 • SUSITNA . ... HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE LRX-42 RIVER MILE \35.3~ ·- I 10,000 I 20,000 I 30,000 I '40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1S83 -----------------------------------------A------------------------~ GBO- &;78- ..J w > w "7 . ..J j; /to - < w tf) z < ~ i W r ',_!;..-~ ;j,l I w > 0 ro < '"""" ' 'I -1-:.f)/ L w w IJ.. .. z 0 ~-­L:; . -.--lC ;' ..... / < > w ..J w fi 4 IJJ(/)1 0 _ .. _,, __ .,. -~- I ----+ --,---1--+ i . ----1-'"'"- --· ;..~ ... + -~ • 1 - I • i - . . ----··'· ---· ., .• .,4-.-· -· ·-+- . ~ -. . -... - ·-~---1 ·---- ----~ -+--_.....,._ .. __ ,. .. + ----.... _ ..... , -- ' . -- _, ______ _ . ' -- ·--+--·---.------11----,. ____ --. -.. -··-r-~---.. --·--..-.. 1 • . ... . . ' ---+----·---· ~---·--~'T ____ _, 1 • • • • 1 • 4 -~f ... 1 -. ·t . ~ -. ... ..J -.... I .... -+ ... ·~ - ! ., -T -. 1 1 • • . ~ • 1 I . , + ... ¥-.. ....; • • J -:· t""'l""'i . ~ . . i ~ 4·-i -1 . ·--t· -· --·--. ~.!--.-- -'1' . .. .... ""! "" "'-'-·t ...... ~ '!'I' ......... ....,. •• ... ., ~ ..;. ..... .,. ~,_ ... ·~ l ... ..f. '1' + i t l 10,000 I 20,000 l - . .. . . SUSITNA HYDROELECTRlC PROJECT STAGE l)~fi>CHARGE CURVE LRX-43 RIVER MILE I '40,000 I 50,000 r 80,000 tiiSCHARGE, CUBIC FEET PER SECOND ·HARZA EBASCO JOINT VENTURE OCT 1983 ;J I ~~ 11,\ ..J w > ~0qo- < w VJ z < ~o88- w > 0 m c( tO• t-l.oDW- w w u. z 0.1'"'\,t -n· ··.-.t=-VJ ..... '1" < > w -' w I B ')-w L r.o78 0 . -~ =--=-· .:.:__-=:1 ~~ ~~-~=-:_.:::--,--.. i ~ ____ ___:_ -·--·+ --·-...-r-----1-----· -=--=~~ ~:=.·-.:"_1_ :--:-~-~ ~1':\ \ ~ TT S<t ~---__..,. . ---.... -. -· •• ..:_ ------·-J. •. --·-~ ---r-----__ _._ ______ --------. -- ~ --..,:.___,; ...... 7' _,.. ______ .,. .f----,....;.---;--·---------~ .. ·-:-· ~ ---+-~ ~ ~--·..,---~· ---+--·--. ..._ ·-----,-.. -----.· -·--__ _:., ·4-_: _ _._. -·. __._. .... _,.. ";""·~~--.. -: ------r--~------+ -· ..;... ___ . ---·····~-----------·~ ~------- ·-·~ • -•i ••.. ; . -------· --··--" ..i _ ____ ......;. ---·------ ' --! ------. ~ -----1 I ---, --1 < ..,_ ... . --.--1--·-·-----.J. ----... ___ ,!.. ___ _ i . -·-·-:----·-+---~---=·.:::-r:-----+ ·-+ .. , --. _ __._ --...... -----~ - I ------· . ----,· ·--··-· -----+. ·-----· .. :: ·--: .. ----- ---4----t-----j·---t-----+-------li-----;-----r-----·~-------.--·--·-------+---·-t-_____ J. . ···- • . I -----f-... --------=--~:~=~=-:~r ~ ::-_ ~-= =-: -~-=-= -·. -:-=-:-::-·::-~ -·-·------------·+---·- ---··•--.. - ; ----·· -. l ·- ---.. ---4 . -- ----·-·-"1-<~--- --. . -------;--·------ -.. : I . --· ..• --=~=--= ----~---------+-----------------------r------------·--+-----. ~-. --·----,. I -j - ,. - t t ~ --. t . --.. _<1 .. ' I ~ . • 1 - ~ . -...... + l - ' -__ -=-t. ~-~ l .. 1 . - i --·-1 • --• -.... 1 • ... ·----......... --·-·. -- . -· : -. ----. -· .. i -.. . 1 ~ ... . ... ,.J -.. .. .. ~ -.. ...! ---1 -• .. : ~-~:..:.: :·L-~:-:.=· ... ___ _:__: . -~ -·---~-_-+----r---------· ··---·-~·-,.+ ... ~--.... -·-.... _, .... -.... ... • ~--r .... ----___ ,.. " . ' ---··T---'"--'~·1 --. ·<+ • -.. "' .. • ·t ' 11",. ........ t-r: -1 • . . -...,..._ ----< • ,,. ... ' SUSITNA HYDROELECTRlC PROJECT M il~ STAGE DISCHARGE CURVE LRX-44 l: :~. --~---~·+-~'!_: __ :~1_:~;4;_:r.4 .. -r~----~-~~1-=.~ :f.~~ ... -i ... 'j • ~ ; +-·· .:.. ! •.•. .l. RIVER I 10,000 ,., 't-......... '"t '! .l f' II! • . .. . .. .. I 20,000 l 30,000 I '40,000 ....... I 50,000 DISCHARGE, CUBIC FEET PER SECOND 00,000 HARZA EBASCO JOINT VENTURE t" ? r I r r l I l t::. ,J :r, I. 1 " _. w > foq(o-. ~ u,qi= < w rn z < w l.t'l" ~ .u- w > 0 m ~ l. 'lf6- w w LL .. z 0 ;:: {a%lt,- cc > w ..J w loC()O- 0 • _j j ·---~----··----------+------1 ·-, =-== ~::-.=~~ ., ----·--------i----·--· ... ---..; -"" , . 1 ·---j ___ , --. ---i ------·-+------------• ---. -... --· i ____ : --·------·--4 ··------~---·-----•-+----... --···: 1 I J r . ! --_J-----• '~ -•• ---_.;..__ -· -----------:-----1 .. • . --_J ---=-r~~~ • ___ ..,.!------.----!. . ----------~------. -----·-·---· ----1 -----• ' -~ ----2 -----1 .... ------·~--...J ---·---•• ·----; ----. ·---1 . -. -~-.. ·--~ .. ~ .. --.. .. ---------~---!--------....____ ---·---1-. .. 1 -. ----j-. -. - J ·• .. ·:~---~r:.: ' -' i--t· __ _:_ -·-i ---.!------if-- i l . . . j . ........ " . . ···~ :.=;=== ~ . --~-= ~ ~ :.:.~~ j;· ~~ :.c 1 . --~ ---~ ~ --· -.. • • ----. _ _: . . .• .. . -. I . ---. --·; _:_ ·-~ . -.... " + . . . -J ---: . - . -l ~ ..:.- -: ---. . : : : -~ ~ . j . - t --, . i - ~-­:~ ~~] .... ~ -.l I -. ., f .. ~ :~. =~-:-·-~-~~~r ~ c . -- ·.0~· -~---·· - -. -i ... ·-. -1 . -... . ... ~ --~----+----------+------·· ---- ----~ -· -----1~---"-· :--·------·-t --__ -v:._· __ ·_ ntzc~u \i:LQ -.• -·-t ---t· ·· · ----·---------.. -----f\-~l..:r~ .V1:.J ·-~ . ---,~--------t-----··-..,----·- -... 1 . --7 ........ -.. ---r--.. - ----~ -4 .... --·- 1 - j J -·---·J . -r:~ ·--_ _J ___ --+ ···---~----·. i ·------;- ----·~----... ··---·-·-·--4 ---·-·---~-.--f. • - --t -· • --· ·--•. -• --•. --·--.J • . --.. ---. ~ : ·-.. 1 • --••• __ ..J_ _____ .. ____ --4---· --·-·· ·.-•• _-_· -_-_._.1.:._. ----.-+----T~~r----i~-~-+' ---·+· .. -___ .;._~ --·----1-----,--:-·-- , ~ ·• .. -- ...:.:::...: .. ; _ . ., -.: ~ 1 ~-: ,.. -. . .. -_._ +--.. -·t 1 ~ ..::..--:.:.: .1. ~ 1 ~ [7 .. : -. -.: -J --·----· . --. --• ·-1 ~ - -~ .. -... .; ~ -· -· ·4 ~ t -'-· .. ~---.. _-t: ---+ • -. . --~ • ! -~ '... i _ _.__ ------------~ -'I ~·:: : ~ ~ :, .. :_ ' ........ ~ -l·- 1 I . J . • 1 . -.. -·i- -- . t·-------1 .. -· . ·-·i·· --SUSITNA HYDROELECTRlC PROJECT ....... " 4pO-- _ .... _ .. . -.. -., .. _ . ,_, ':' .,_ .... ~; ..... ---: ..... . --,·--·. --.. ~-· .. ..: ---~ ... ~..~ .. ---~!. ~ ...... ~- -.,: -: ! .... ~ . . -.. '~ -· -1 ~ _ .. _,_ -. ' ~ . . STAGE DISCHARGE CURVE ~-4S . : I -..:. ..L.i ;... .. ---l. -!..-!...!-. RIVER MILE \ ~ t, .to co ... "'" .... ..; , I • t f • .! l., ..;j-:-+~ ··•-""""--' ,._.-!.,.......... ":'~ J ' ' . ..... ,..~ . .. ,. .... . ~ .. --~ ~ l ' I I I * ·I r 10.000 20,000 30,000 '40,000 50,000 60,000 rNICHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOiNT YENi·URE OCT 1983 ' I II il ~I II 't 'j li I '·! lJ '1 I II hi I ' ;I\ ' 700- ~ w > ~~gs- c( w C/) z < ~ ([;~.o- w > 0 IIl <,a.: . t-W ;/ w w u. z Q r or: -t-;J)-l L < > w ..J w -- I --i ........ ~. j - I 1 ---. ......... ' ....... _, ., ·-- 1 ~ 1 • 1 • .... 1 _,....--+-----7 . 1 1 • ~· T ' +'. -- ~ • . : : ... ·--jl ~ ~J-= . ' -~ :: ~--: -·--: -~ 1 I + ~ 1 ~ • " ------~~,------~~------~1--------~-----~--·~r_·-------~---·_~_-__ -_.4-_·----·-·---r-------;--------t-·------~--------­ ...... J-..... ~-~-·---< .. -... "" • i 1 . ' • 1 • 1 -i -...... - I • • • ! ' t ..... • • I ·· · • • i ...... . . I • 1 ··~.~ ... ,...-i •• J ---·--·----....-~-•••• . •··· -.... , . --·--1-. -. + ---~-....... _.,, --~ --·- -·----l--..------ . t .. i . ~- . t • I • • • -1 . ~ • -1 • • -T- -. 1 . ..,; ....... -· -- .. .,.., __ .,..... ............. ·-. --.... ·-1 1 ... • • I SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE ·i -'--; ·-----~-"' .. j .. • " .. ... ~ i ~ 4 ·~ ...... ·-"7..., .............. __ -1--....._ ___ .~~+-.---.--.~~ ... ,- r • ' 10,000 ........... ..,.. .............. ,.,. i 20,000 I 30,000 RIVER MILE I '40,000 137.8 ""'·'i 1 50,000 DISCHARGE, CUBIC FEET PER SECOND eo,ooo HARZA Ef3ASCO JOINT VENTURE l /lD- ..J w 70fJ- > w ..J 7DlD- < w (/) z < ~ 704-- UJ > 0 OJ < ... 702-w w tJ.. z 0 J' ·. t=T a-< > w ..J UJ L?98- 0 ------~--1 ·---···--;---~ . --------.;· --~-__..,.___ . ----.. ' · · · tl~B\T La\ -.. ... -1' .,._-~--.l -·------*" ·-~---~ .. .,.___ .. _ .... ___ _ :_· ----·. ··-------------+~----~· --_ -- -----!-·---.--.----· I l · I --+-----··-.--·-~+---·--- • • --· .... .,._ .. ___ ..,. ,-·-·4---T ..... -------........ ~·--- . --.. -· ~ ...._ ---·-· ---. ---- ---..; -. ---1 .• ! -+· ~-~--... _ __;.... ____ -------.. -... ---. -.--r .. .,. . . . l ' ----~ ..:--.... --.--.. .. ... ~-..-~-..... -r-.....__""1! _.._~~--..-------. --; ·-------· ---. ---.... ·---~ ·--·1 .. -----"' .. " -.. -... ~ -·-~--_,., .. __.. ----·· --·---... ------~-· ---j i .. .._. __ 1 ~ .. .. ...,....&. --·-• I I . ----+---..... -_ .. :---~ .. --___ .... . --. -----. -----·-. ----------------' ~ --~·---....... I 1 --. .. -..... _ ------• --_ ...... -----~ .... -.. -": .... ~---~ -.... ·-...... _ _, __ --_ .. . ---... ---+--·-.. -- ----.-----+-----------------+-----.---~--. ------<-----+----_. . ·----. 1 1- 1 -r • 1 j . l -l -~· ... i• . ---~--•• , • -~· ···-·+------f..-~-.,. ·i • T""" • -• • . • • • • •• ! .. -1, _. ..-.,;. • I .,. ~ -+ .,. " ,.. - -4 - ---. -· ~ ...._ J • --,.. ~ J .., -.,. ,. .. --+ • ~ ~ --. __ ,..a ~ .,.. ,.. -..0 1 • "' . -_ ·----:· ~. -.• · r--=-=-~ -+-1-:: ~~ --=-r~-=-1 ~·-_ -_-4_ ...::::.. __ --_-: ·: i-:: : ::: ~~-:·~t-~ ~~'"- ---.c ;r i ~ -• --• -~ !--• -. ---• -• ·-• f ----~---· • i ~ • --./. .• 1 • 4 • i .• t . . . . . ~~ --I ..... s " .... , .. ' ........ --· ... -l • --• . ~ -. ~ -· 1 J • I j • t . !/'---- ------·~----+·----+-·----4-==-----L------+---·------r-----. -- • 1 I • : -·--! • ----. • --1 .. • -1 - • ----. ~ -'"'"'t ....... • • t t • • •'I ~· , ; -_ .. _._ ! .. ~-----1--------., . . ·~ ·-· :1 -. ; "" .. .. . ... i .. ------~----------~------~------~1--------~------ I .. . ' J ' . ... .. .. ...... 1' -' :· r ~ .. >f • AI • "'1: .J ~"' "" • • .. .., .. -~~~---~--~~~~~~----~--·-~ . ' .... -. I . ' . . ! ~ ~ .... ~. 1 "' t• . i • ! -. -. ~l . ·- -.. 1 l ' . ~----+--~-------+-----... ·- T .. _____ .,. ....... ,. T'"""" -~-... SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE LRX-49 .'liVER MILE 138.23 l 10,000 I 20,000 I 30,000 I '40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE I n tf ;:ij ~~ ~ ;•:t 'i Pi a~ i ~ ,'~ "t ;~ J-If l ) ~i Hi ]i -~ '( :·}1 ;~ ,jf ' .~ . , ' ~~ Li \ ~ .. ar j~ :~ ·' ,_, ~ ,, :i ." ji t •• ~~ :~ ,, ~~ Lfr ,1 ~~ '" '~ u ''It f m I . ~ ' ,\ t._"·-"-' j i~ \,!~ \! ~~ " ~ ,J t~ ;j:t f\ I (I ·~.: -~ ,, .tt ,, !! ~1 ~ ~ ,] ' .. ~~ :t ., r _,, .:r~. ~~ .{ ) ,·J _.l ~ / %'J 1. 1: H .~ i ) ' ~l I f j ,.i: l;, i '! ~ !} a t:'f " '·;;) ' t-\ ~'I I: il :1\ \,. .:·; I 1 \ i t ., 1·:{ ~ . 1 : .. I ! I f: ~ g '• 1.<./~ : ~ ' ' ) . ~\ fi '\~ ,'(J .,~J ' 1-· •I I•' J ·_ =Erz..- ..J w > w ...J~ . < w UJ z < ~ ~~- w > 0 m < 1-:ttf\- w w LL. .. z 0 ~ t-OL- < > w ..J w 0 _.:__._; ;-".~ --r-: : -· · ----........... , ,---··. --~ .::-".~ --~-El.-\'\\~ IT. bL. . --_ _j -----.-~.;._-r-----t----+---t-1---i ---~--. . -· . --.-+ :---1-f--: ; ; I -"~--:--~ ·-----~--• -----....... ! __ J ____ .... -~..!....... J •.•. ~ -·--t--_.:......, . .,. ... -------~·-·· ... -·-·. ·;- • t i • .1 • . • ---...----=---~----~-.,.. --.--·-t .... - -..; ...; .... -1 ·-----:......~ -t f--i-· ---. ! • • -I • ·---_____ ...:.._;___: ___ • r-. __.... -, -~-·..--.-----------... ---~ ··---· ·-. • l ' . •• I j :.__' J • • •· •·• i-· ·•--1 •• -• ·--·---~-----~----------.-•7 j --T ---··· _.....;:--------4---+--·-··· --·-~ ___ ,. __ -··---+ ·------+-·-----r-------+-----. -· ---~ . --- I i I ! --~-------l-·-----+-- -_. __ ~ __ -lL·:~~-~--~----~----~~~--~-:~--~1~---· __ --_,-______ ~·------i------i--·----.T------~----· --·l----. ---·-----t ----!.-·----+-----~-----l------. !. . . ··--- -------+----1·--·--... ---------------.. -· -. ---.. -~ • • ------~' --· ------J . -' ------·-t-·--------~-·_:___ l .. ,... -__ -_-_-:1'::.: ~ - . --·-~ ----. -·--..J ------·--. -----·---~ -1 ----·..;i --·· ·----... ----·-----·---1 -----~---· __ ... _______ ----;·• . -----.-----· -----·1 -------·--------r---------·----i ----~ -. ---.! ----------··----.----r----·-----·1 I ... , .. . -·-----. .;__ .. -.. -~ ---·-- . -__ _,_ -----______ _: ___ -------1 _____ j ____ . 1 .... -..... ---1-------l--·--r------:----·---· ~-. --. ---. ... ~---- ----~. ·---.--·+-------____ _; _______ ·---~---=·1· :-~-~: ~~-~~-= -----1--..• ---~-... : .... ~ -··---' + --·-------· -------·---.,.----·1-,_ ,. . ~--=:-~ = :;::-:-· -= -=·=-~-J -·-• --:-~ :~=-~:. = ~ --~: =-=-· = =--· -· -: -=~ ~ = ~ : ·: -~ ~ ·-I 4 --4 '"'i .. -.. ~ ----~-~ -·- • . -·--t --------j--,-. . .. --·~ ~ • -1 .. -----t : . . 1 .:.=:::: i-:: . == .. ----1'. "'-·· ---=--~=]: ~-= ~ =------~~~ ~:..: /~~-=~-~ ;:=~-=~·-= -== --···· ·······!·/--:----~-r-------·--·--··-. . . . --·-. , -.. . ... --·----: ----· .. +·-~ ··-. . ·----;-~-·-­ -----·-I -• -• --~ -·j -------. ·--. ; ... ,. ' -. ____ .,. __ ; -·· .i ... -. , ---- 1 A I • ,·. •·-·-•• •-------•·-•--·-····-• ·--- -• • • -;;_ ~ • • • •----• --·"'"1 • --•. - --• . . • -/\ 1-. -. . . -· . .. ~--. -.... -. --. ·--·-.. . . I --·-~-.. ---·· --------. ----: ---·-------··-t --------. --.--. ----•.. ' - --·-.J --. -·. -.... ..!----• • --• ·-" -·--• i -·· -- -=--:-1 } "" -~-I---.. ----l· --·--·-t--· --· ··-----• ·----.. ----. ·_·1, .·_-·-_--------___ .....,.... --·----r-·---r-------· ----·--~ ------·---· .. ~·... .. ----·---·1----4---t----·-·-----,-.---· ·---1 .,~.. .. . --.... ; • -... l . . . -• . ... .. -·--.. -. I ----+ ··------i ----. . ... j • ---vj -1 --... ···-, . ---=-=-~ -= ~:-; -=----_:·-=---=-=-=-Ys-::. ,n.l:~ ~-f:O: -~-~---... ~ .. =~ _:_ ~-~ -_.--_ jil ----·-·--·-t-----1·-·-·...--i-~ :--:-----·. -·---... .. .. ---;--.. --·-i·--· --· ~--; .J-. --... ---- 1 ---• • ~ •• -·-· .. :~ i. : ~-: ~ j :..~ -2.-:· ~-~: -i~=;-~:..:-· :-:.=-~ .::= ~---= :.::_: r: ~ . 1 . ~. -:· ....... . .. -.. _ t ··~ --... -----:--· --·--....... ---t· .. --... --, .. ...:.--~ .... ~ .... -~ , ... --.... ... 1 • ,.. • -,. .. I-· ..jj • _. --.. -• ... ---. --=--=-= 1 : ~ : : ~-: =-r : · : ·: : -= ·= ·-: ~=----. - . ..., •• "1 • •. • • •. -... "!. --. • -i------ -.•..• --. -·--1 . -. . . . -' i ~ -----. --I---·-- --. i --... -j. .. ---·---· -•• - 1 '" •· .,.. 1 <t ·-T -1 ..,_ •-.., -,. __ , .. -••• ·i .• ----. ~ .. • -----·-• -. --. . ~ ~ ~ ., . . . '. -1 : -· : . --·--t--·- . ~ --.:__, .. ... • •••.• ...: ..:.. ._;_.,,_ -r_-......... ~ ...:....:. --. -. -----. ----.... ---. ·--~-. ~ --r:.r~ • • ~ i "l" • • • • . -•• ,.J i -T ·• •-' • --~--~ ~ --• f 4 • .. • ' • ~ • •; -; ! J • • • . • • I • ~ ..; -1-: -1 _; -~ .;_ ' J ·-;-;- ~ i .; , ~ .. ~ 1 .1-.l-L.! •. '1 .~-+---= l l l • ~. • + ~ J. _ _! :_: -··~ , .... ~~- • ~-J-.:..-! ...l-i ~ --1 SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LR.'i -~lJ RIVER MILE l~~.4CO I 10,000 i 20,000 I 30,000 l '40,000 I 50,000 eo.ooo DISCHARGE; CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 IJ Jil Yi d q IJ l I f ,J q j\ II fl I! 'l l: .. r 1 H f t I f l~ :., _, w > ~ ~\lo- < w en z cr: ~ +\4t- w > 0 m < :Jr\L...-.... w w IJ.. .. z 0 i= +tO- < > w ...J w ~- 0 -. ----·-1 - ---·· i-- . 1 .. :~-·-.. __ ... -.--·--:------+ . ......, . .. 1" -··--·-··•------ ---·· ·j . -.• ~"D\\"l...i\ '-~ ------t ---~t;~t"R\·\: .. H \ ~ .--+--.-~ -· --· -·4-~--· . . ·-----+ .:..-.... . .! ...:,._ -.. ___ !._ "!'~ -·-· --·---f----:----· ------;--------! -·· ------.. . . -· + • I • ----; -. ----. ----~ .. ..;; ... ~ ---~-. ---~ --·-. -·--.--~--___ _: ____ . -----t-----~ . --1 L - I • ---,. --------+----i------!---·••· ·------; '1 -==-r:: :--~--____ ..L --------------·----··t------:-· ~ I . ~--·-+. -·-i -·--1---·--·----·""""'!----· ····--· ' . --. 1 ·.·---·l• --• •• I --.---. ""'1 .... , --. -. -~ •.. ·• --·- r--· =_=_=-~F ~ .: :-i ·::: --~' ::: :·~:[-=:-::=: :-:· =-: : =, : --~: :: _: :-_: ·1 . . . l--- -.. --.. .-; _____ : -.......... 1 ----------... --;-------r-----~----....... ----·-~-.... ·1 ---- ~~~=-~=·: -~-=t-=·-=---=-~ -=--=-:~-=----~------:---~=-. --·-------J 1 ·-----· -· 1--. ·--·· ---·. • ----- . ----~ . --· .. -=1· . -... ·-;------------;---- _-_·-_·"t __ -_._._-----~------l.:..·_-_-__ ~--------· _-_-_-__ . --i-----·------:--. _-__ -_·-----r------!·~---+-------;------· ----·-, ~-1 i. ·---.. ···----_______ _! _____ ·--:--, ' . ---..... ___ _ . ' . ~ ~--' j -·--' -_ '1 ~~-=---= ~ -~ ·:.~_: ===-·-__ . -==-~ ·=----: ----~---· . -. --==-= -~ . ·t • •• •• • • -;-JC ______ ··----·----; • •• !--. --- I i • .. -.. ---------·--............ _ ,.. +-- -·I-·---1-# ... --=-:=~~-~ ~~-: ~-----: :~-::~ i ~--~ == ~ . -.... !-=-~~~ E-~l :. --~ -~-:.--=-.. : ... . -.;. __ -: --.. ---· -i - . -----. ---:-----. --------,1---~-------~----. ~ :.:..~ ~ ~-~~-= -~ ~ ~-=-i ~-= .:.=. --=--=.:::._:-~ ·-=~-=: . . ... .. --· ·-.. ; - ... ----~ .. -... - -! 1 . ' !. ... - .. ..:.._ i ·-____ _J • .. --... - -... . • • -----• ·-• ·-~ . --,. __ -___,. . -__ ....... --··---·--·---~-·---~----.. --·-..... I -------. ·---~­ ---' • J l . -·-·--j ---··'·l---~ ~~~:; -t -1 " ,.. .. -I --· -.,... -·-·-· -1 . -·--:~··:= ::.:-~·::.:. __ ·-;_---~~l:·~~-~---~---,1-~---. ' -.. -. -·... -. . i 1--¥-~---· ·-. u· --. -.. ~-.. ---~ -------· -.. ·1 -~ ~----l ~~ ~ .-:-:_~-~ ·:_.=---=-.--·_-1 --~-=-=-~·-=---*-~----_-_+v--_ -r~~:..-~=--'j;..._~---------~--t--. -_ -__ -_-·-~-G:~~-~~ · ~ · ----•-i ···-·--, ____ _c::z ·----·--r---· ·------' :1 I·-~--• : • --. 1 . .. . ----4 •• ----· -v -1-~ ---·-·-+ ------ --__ .J ---· J ----'\ 4 ---~-' --·---,_ ----~ ---·---- . --·-~ ~-:.: l71=--~ .!~ ~ -:--=----=-:===-:-.~ ~-~=.. ·:. ~ -:'/.;._ ~ {\· ~\J f:.Q -J -• • . -.... --------~ ---., "' " ... , . . .. . --. , ---~~--~~------'7~~~---+'------~----~--~-t------:-----~r-----~·-:·--- : -~-: : 174~ 0~ ----~-~ =-=-h :.:~-.. J • . ··1 . -·-j ·. --- ~ --· -·:-- ---• 1 .. ~ ·------,-~-· ~-:)( •• ~ i-l ----···--·-____ .... ._. ____ _ -v·-.----,_ , . -; J • ! • -. - . . -. . . ·-r-·. - .-., ·----:-·-·,····-· -·-. ~ .I···-; __ 1 __ _ =~:J ~ ~! -····/:~ ·---7--. -. ..., .. ~ --·• . ·r~: 1. . . ..: . .. . _j • • ... .,.; ... J,. I ..... ' --·-' j .. - _,_: __ ....... -{ -.. ----~ --... "i __ ,....: ~ -···--r --- -... -; ·--,-~ -+ ............... ,--~ .. ---..t...1 J,._: ...... : ..: j -. _._j _ _i -.. .:.._ J..-t~ ~-I I • I t ' SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LR~ -5\ RIVER MILE \3'6.. ~t; 1 10,000 1 20,000 30.000 I "40,000 I 50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 l!.ll l ! ;i ,, 7Uo .- ..J w > w7'4 ..J I - < w t/) z < ,...... ~1lL- w > 0 m <C fl') .,_ tiL - w w u.. z 0 '\--r' ,v.- fa-vO < > w ..J w rJ), -: . 'J) 702 0 ---j .... ---r-·---·-·-------~-·---·~ 1------+---. t . ------~= ~~-~ -~-=--·-·· a:tt\~IT L.f1 ~----~ ' . ..; ---~ ·-----+-·-·. ~ r-··--· -------+-----·---·-+ ................. ----t-~ -------··--·-------+------,.~--,......,. -~-~ .. -... --..:...~ . -· ----;· --.. -__ _;_ _ _:. .. ...;. --- ' ----· ·-·~---T--. -... --:------·--~--i----_: ... ,---_;_ •·...:. .. ----+-..,-!--------.,..--~·---· ~. _ __. __ -· _.. '1-+--____, --r-----....-~- ~ - -----··-·-· ------____ .. _ l _____ _ . -.. --... --+ ·-·---.... . ------1 -.... ____ -i • -·--··"'t ------I • ------. ·-----'"""""" ~ I ... • .• --·-L, ----·--·-------·--· . -l .... l .. . ------+---... ·-· . ----·~ - --·_ . _· _·_-~ -----~-~-=-:--: .. -~=~ ~ ~~.-.. ~~~~~~-·~t:.· -=.=-·:._=-' :~ ~-==-----~--=-: j . 1 ··_-_· _-_lL·_··---+--~+t----+--+---1--------t---·~--r----··-: -----~·· 1.. --·----!--·--·---' -4 . ----1---- _ .. :·---.---~-~=.--·----. ------------~ --~==----·.--:-=-.. -f~-----1.----~ . . -. -.. -----··· ~ --------- -. . . ---·-·---.. ---·•. -. J.._--... -.-----------· --• -~ - - ---. ---.. _. .. .. --··--~ l --- .. --+-----·-4---- ~· T --.•• .l. ~ . T • ... -----···--·--,------ ··-+ •··-·--·--· ·-. -. .:. ... ---~ -· -· ... -. ·--·---..,. .!.--··--·-·-··-·----. -· --"+ ..... ~. . t------.. ,. _,_ I . i -t. : 1 :;r.: ~ ~-.: :=-:1: .. :~.--~-~~~:·= -~·:· ···--· l I ------+---------~'--·--+-----' ·--· -1-·---_l·-···---~lf-----· -·---~ I/ "" -.. -----t .... ., v· ....... -t---.• 1'·------~·-·-----.. . . .... • l. ·;· -~.J.-..!-. --~ ---·---------+----· :_ i ~--t ______ J -----.. -~ 1·----. ··-··· .. ··-··-. . --·-+= :; -. ~-~·-i ......... -·-·-t·-·-----~----· ·-·-'. ~ . ' 1 .. ' -~--· i --. l -f. ; - "1"7'1 I 1 ~ - ' - ,. - I ~ - t -.,. -.. + --1 .,. .. - -i -~ --.·--·1' -·-~-···-·------.. . ---·t --.... -·· -.... -+ .; --~~~-:_:_~_·4~---··------·~~·--~~------~~-------~~~~~~~~,~~~~---·---~ ... -_·_--.l-~ ·= ---.. l ---r -·-----,.. --·--j ... -.-~ .. _i ______ .. --------+ ... ··--- .... -~ ~.., .. • ... ... -------.--!.---· ... -·--~----,..-----, ~ .... -·-..... ~ I · .... ...!..-.... ·-· . -·----+' ·-•---·· · ···-· l,· -• • • . i . . ..... -·-.. ------~------+-----~r------t----~-------+------~------~-----.-------t-----·-r---------i . j -.,.....: - -.. -· . --·--· -···-. , - -----~ . .. .... ------1----·-· ----+·· ---... ----·-.. -. •--··-1 ··r··· ·····i·------... -----l·-·-·-· .. . -r·;·-~· -i • "* ~---· ..... ·--··l··-·-------·--t--·--., ..... _,., __ . + -. . ---~~------l---t-~-!.---...-t----r----t---..,.. ··-··------+-~-~~---.-,~.t-·~~----l-t-l_-____ ....,_ -----~~--·--· . .---------· -.. -+~-"'t .., --'"~ • • ·~ • -·~ -~ --·-.... -· •· .. 1. : -, ~ J. ~ .., ~ ., .,. T ..0. ,.. '"'! j • .,.. !' -. •_•• ~. •• ..... ..,. .. ...-~ ..... "' -..... -... ~ -·- -._ ... ... • .,. ..,j, 4 --+ -...: +-1 -1" t ........ t· .... 1 ·---l ~·-r---·i ~ ' j t . ' • -1 .. ... • + . .. .... .f . ' " t ~ --. ~ .. I l • ' . ~ ~ .. t ~~- .:. .. -- ... 1 • ~ j ! .. ~"'' .. , --! -"'1 +·· +......;.. T -~ ... __ .,_ ' ~ ~ '":'" T ·~ ·-4 + -l-r .... _~ I ' ' .... l ! ......,_ ""1' ~-., .. '1 ; . I -- t ....; .. ~ .. --! .. . . - * t-....... t--~ ..... --, --t---· ___... - --.-t .. " -. ~ -~ ·t .... ·+"':· ,., """*'"t ...... ,..., -. J ~ . . SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE RIVER MILE ~·· --~------~-----1 i I 1 10,()()0 ' 20,000 30,000 '40,000 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE ) > . -~. i tJ1 ,! .. , 1·. . ' ' . 1 i . i L • . ,, i;.; ' I ..J w ::[£_- > w ..J 1U- < w rn z < w Tllo-~ w > 0 m < ~ w w La. .. z 0 ...,. 1-c: > w ..J w 0 ----·; __ ·----=~~----~---• .. ·--;7----~=-~--1~ -~-~-Bi:it~T\ l!6 __ ... ----;- .----1 . ·-----~---...,._ -·--j·-.-·-I ----t -·-· -... t • • __.. ----·---.. --·-·------.+ !.-_:-.--• ----~-----·-··•• ~ --~ i • I ---..J ---• ...:... • -..;_ 1~ ~-~-~, -------· ,; -----·------·-........ . .. ,. ··--~-~ "----·-_,.....rl -....-----:----r-------:--·-: ----r----.. ..,. -~ . • I • . ~ ·-r-· I I ---.-------~ . ·-..---------:.--· ------~-,. ----~ •'l"'"<r --:-··-~ --_. -r I -/· . . J _. ~---·---.--~ --~-----~-----------. -·-----· ---. ··---; ___ J. ____ ----~----. ------·t----·--=t---J ··-. ~ -:i:-:-:-=..== 1-~-----=~-=--=-_;_ _____ ---·--t--·-l-:~~:-.~~ ~ l-~~ i ·------1 . -----··----i . ----· . --t-----------+ -·-·-• .. --. - -----·-I i ; ,_ =1:::~::.-:~-~-t--___ :_~-: t _ -:::r==-:-::==--=:::::~ 1 = ------1---_:_ ~ .... ~ .. --... ---------------·---"-----·--.. ~ ....... -~-. ---_--------= ·-1 . ~ -~ _:_ .. . -- --..... - --·-· 1 .. ~· "~ -.l . -----: i ---i··~ :-1 -·J ··---, --· ----------------. --~ ------------~-----··-----:------. -----· j 1 .. . .. ...., ...... ----=-~ .. : -~--=-=J":.=_: =--=-=-~~~~--::::-..:· -~-=::. ___ : _____ +-·---· ..... ----• ....J_, ___ _ , . ·---.-----·-·--------·--: -----------]. ' . l --·-- -. ·-.l. ·--·----• -·---·----~---· ---.--.... ----. -i ---- I I -1-• --•• • ... -· .. ~ -••. , --·---~ ~-.:.. ~=-. ~ -=--~-::-= ~ -:-r·=-== : ~ : --~ =-=-------! .. . -~ . ~ J ---• ·-J --J ----~--·--L . . . . . :~: -.:~~ .=-.-1 : ===-:·.-~ ~ =--. -· . ___ ... -·: -----+------·--+----_·-.. : : .. --f.-·--.-: -~---+------1-----t-----;,-----t ! . . . 't ~--~ --~-4 1 ... --·-., • I ----· ~ -~. i --~ ·; J -.. i - - I -.. -, -. .. ! - l ~ . •· -..... - - J -.. -::{0--~-~~ ~ ~---..... -~ .. I I .• ·-~ --~ : ~... ----... 1 ·-- -I ------· ........ --... -. ......__ ----; ---.. t ---·---~·-· - -~ · .. ~ {-=-~-:~.:--·-----; ·----" -- 'i ---·-J. - . ---• ____ _j -..... -... ·--·---' ---··1-... - --, ,-·--- ---. • j ·-. - --• J . ----~---- ~ =-~--=-=-~ = L : ... : =-:~ ~ :::-:-.: ~---=~ -~--~~· .. --·:-----·-f-·--·l··-·----. -. ------, -- __ L_ _____ + ___ -_-__ -_·~~------~----+------_·_·_-~·------t---~· --i~-----t-------r--· ---- ---_· l --i -------------~---· . ---. ~ ' ! • -• ~ • • ••• • • • • . ·' . • --• • • • • - -I -="~ 7:::·-=-=--t-~ ·=-=-~~---: -~ ·-=-~-~ ~--=-= ~ -- -.. -4 ---·-j· -. ·--~ I •• --• f I "1 .. --··-"!·-.. ·• ., ·-----· -··::"f~·r·~· "7 -v ... + ,._, ,...._._.,.. -----r.....;.·; ~· . -~ -·,--. ; I ~ --~ ·-.. -· --• -I ~ ........... _-r-;-r- SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE M~\ t\\.5\f_~ IT\ '5L()~()\\ \9 RIVER MiLE 1 10,000 ' • 20,000 ' 30.000 I '40,000 i 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 ·-· (j I c i "'I 724.- ..J w > w..J 1721'1 -I L c( w U) z < ~720- w > 0 m <-n t-'j,[J w w u. - z 0,........ i= flt.O -< > w ....J w - 0 ... ·----... -----.. ' .l :.··---- . -+ -----;-·---y . : . ~ ·:.--. . . . ---. . . .. . : :1 ~ : = J : ~ :_ ~ i .. ..l . -t· ~ .... ;----~~--l· / : t-· . --=t -·-_--~-~---=-·..:...: . : :: : . : ~~ -v ~i ~~:: :~ ~~~j~~-:-:~j : ~~: : . : r: : . : : -- t --• 1 •• -.• ---1 -~-1 . .... __ .. --. .. ~·-..... .. i -t-.. _ -T . ~ . ~ -. ·-··-·. . --· . --.----j ---t---...;---t-------~--· .., ·~ 'i -~ --.. _ ---T-----• _.,._ ~-__ .,..,. .. ·--·--~ ~-.,_, ..... ''" .... .! -·---·----:-~ :-=~=-~·==: J ~ :·~-:: . .... _ J --.: ~ L: :.::~-. l ... --··-·+ • -i -·+-..;·--· ·+-I-•. t • . •• t -.. -. -., . -J • t .. t --.;. ---r -· ·r--! · -· --·· · -----r-----..-----·+·----...i-r-----+----;----·-+----------------~ _____ , ---·i--· .... -- . . ' i . . ~j --:_ :. ·=-~ ~ .: = = . ~ : . -, --: 1 • -.. ~ --t -----·---·---j --. , -... ·---+ . -.1-.. -- 1 I ... -..... j_ -!. :: : r ----r---+---i----+--~--+---l'-----t--~;--j·----..,._.. ___ ·- • --·---·-·1-.•• . 1 . i -;-------""··... _, ~ -----.... ~ -·+---- J---. .-- ____ .. -~-.-...;..--~ -· -.--. -.. --T"'-., _ _. - -..... + ... ----- ............. ---..·--· ' ... ·---;-·-......... -.... ------.J. --~ .. -- • 1 ..... ----·-----4 ,.;. __ ~ ! .. -. ~-· ·-- ·-····-·· i 1 ·I • . . -----~------~'------~--------~·--~---i--------~·------4r------___ ___;, ____ -+~-+-+--I --.---~ l 1. ~-~ 1 · · ·:_r~:·---·----~------· --~-~-----+--~t __ • __ ·~------~~-----'-'-·~----·--·-T~'--------~ •111111111111111111111111111111111111111111111111 .. -. ! + • ~ .. ~ - I -.... ! ' j • 1 -,_ . - . t • --1 ... --t -SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE ; -~ t : • .t • - .... + .J ~ 1' -1 ... ..; ..._ • .._ # ~ i ~ -4-~ ,...... -----.,-~--··-+--..,-----1-~-t-· ....;:H-+---t-"~.......,_ > I t :;. T t .-; ,. • "f '+-... --+ __ .. ,..-t~ 1 10,000 ....... .J ' .. t"' -·"" ... -J,. { 20,000 i I 30,000 R!VER MILE I '40,000 139. 8~ I 50,000 DISCHARGE, CUBIC FEET PER SECOND T eo,ooo HARZA EBASCO JOINT VENTURE OCT 1983 F' ,.) (; I f ,. 1 ' " ·U il I _, w > ~ -=r35- ~ w f/) z < W-=t-US-~ w > 0 m < t--=tlli- w w u.. .. z 0 ~1-2...~- < > w ..J w -=H.to 0 _-_·.: ..:.~ ~ ~ --~ ~ : --' - - --·-j ---.-~ 1 --. 1 . -. . 1"1:"l 1\\ n....,.,.. l _-::.. _-------t--o~ -----..----4-..L\\t-\4\ l LD -~---..... ----·4----~ ----! -. +-r-·----1 -·-:----• . --' I • • ' t -·-...-----·----· --·~ ---- -. - -• ----;-t ~ .: - . ~ ~-i--·---· +-.:__:_-r----+--.....--~-.,.--+-----ir-:---t--.....,--'- ' ----;. ~ ...... : !. -.. ~ l.-~ ... -: .. --: ··--~------'--------~---·-··-·-· --!-·-· .. -- ·----"-'.., ... __ -.!.. ~----t -· -·-·---.----- __ • ---L-.~ ·---:: .. • -~ { .. ..:--. • j---.., •..-'"T~-~ ' •------... ~--..; -..._ ... ---.,. ---..... · • I ------~------·---·· .: __ ---------1, -.----f--·--.l •• -•-·-.. ~ -----. I -, - 1-- ---t--. -; ----~-----------j ____ -- l ., . --·-· i---· ---___ _: ___ ·-------~ . --l·-. ---1 -. f----+--------~ : ·-: ~-: ----1·-=t -. -_ _: ·----··--·-·-, ----I • .. . ..,____ . ---__ .. __ J!---·---... --... -.a--.. --·~· · __ · _----,L:·_--~------+-----~--4----~---~----~--i·----.----l ---. ~----~------1-----·----------·1---------; ---1 ~--. . ---! --------~-----· ------·--- -__ j ___ -- -. ___ _;----- !'-" -----..! -----I ----1 --· -·---~-. I . ----~ ---. ·-. --------·----------· ' ·------~ .. ------·-._ ~-----------~------· 1 ... • ----J -. ---! .. ·-.. -. -I • -· ------ •. ---·-·-J •• ---1-·---~----·-------;---------J ---... ------· -~-=--~-=--=,...'-~--· : __ -l __ • -~~~-_1 ____ ·---+------------"---· ·--·----!---· -~<-----. I ------; -t ____ ; _____ -·--------------~-----------.-- .---·-; : t ------; ~ ~~1-.. ~.: -··---·------~---· --=-==-~. ~-=-=~1 --=~ --l -----... ---..: ·1 1 ·t ~-~'"} =-~: -~~-=-=~ =~·:·:~ .-:-:: t ---,--t -.... -·{ . -- .. ~ ----- ----.... -I ---"'\, ~ ""---i·. -.. --.!..-·-·-~------... --------. -·-...... ..--... ~ -..... _j --.--. ... ·-.. -; -.. --· ··--... _.. -.... -• ~ ---.... --'! -I • I ""-·------t ---,---------·--·-----·, :-. ·=-=~: :··- • ' • • 1 I 1 • ' _..;.._ • -- -, - I . Cf I . - =--=-::-1 __ -:-~. ~ ~ l~-- --j ~ 1 ~ j ..... ---. --,--. . --; . ---j . -. ----·---·-----. . -- - . . ---=-1--- . -t ----------·--· -· - - . -----.. ---"': -.• i . ----------.. --· -.,----------- _ .. : .r· l ____ J ____ f------:----_ _ ----'*-.-n-ffi.P\JW ---I ·: -.: ·-J ·--~ -----. ----·--r --__ .. =-~ -·~-:-: ~ --~h-: ~ -. --: .. --, -.--"' .... ~ --" ' ... -----........-.. . -- --•• ...; . -_; ---1 .......... , ----· --4----. --·-• -•. --. -.. i ---. ' I '-·--' : / --·-j ------------ -·--•.• ~ • . -i • ---~:·=J1~-~~:= :.:.:·1· , .. :-~-;-;-------· -·~ ~ ,..J .. _ ..... -~ -~ .. .. - -... .. ... .. --... -· 11 t ---... -~ -·--. ·--.--• ~ -.. • -"' .., -t --~,···· ·-----·+-·-· ~~:~/: -~·--J I ' --·t-. -[-.. --... --,.-~·-: . ----1'---- -~ .: /J. -. . . -·--~I~ '- . i . . -. ~~: -__ --· . ---,. __ .. -___ ..: -...,. _,. __ --....:!.-..... •-r -"". -.. -·-~....:... ... --~· ---.. i _.,.,_:. ""7 ---·-· ' • I -. . ·-...:: . • -1·-: ~ .... t .• -~ -. -. ' . ..... ~ .... + -1-'! . • ----t • ·; -- • ... ,_..; 4or-; • _., __ . .!.-4---t •-- ' t .... • 4 ..! i • -! .J..~ ! --.........: l ..!.,...~.-._l. • ' . .. .!-..._! ~ -·..J ~ .... -t-=-f T .. -~-. -' ...... ~ ... '"!-of ' . - f ' J -~-- SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LR~ -b~ RIVER MiLE \~.\5 ,----... , --...... ,----, I 10,000 20 0 000 30,000 '40,000 50,000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 ' . . , ·~· I' ' ,, l, .. ' /42- riiO.- ..J w > ~ 138- < w U) z <( ~i3b- w > 0 m <,...3,1 - 1-. T w w l.L. .. z 0 t='732 -· <' > w ...J w ~3)- 12l.o 0 ·-r --... ~--·-·---··-- .. ~-- I . • .J -·--~=:__-~~ -=~:-= :~----~ --.,. ----- ·---1 ---~ .. - ~--·-· ------·-·--· . ~ ·-·-·-. • ~=-:::-~~~-::~=:::=:~r:~.~~=~--~:::::.::1 .. : . j_._-___ j_ ___ ~ J ·------!------------4-----· ---L-~--. -----i--- • ----l --..• -- -~---1 "'1 -.. ---·! t t-... ! . -----____ ...;. ______ -· ---·--------~----+---1 -·~-•· --~ ----· ··--. ------1.... -.·- .............. _ -~-........ -.-........... . . ·-·----1 - 1 -· J I J -1 --. ·~ i .. ----.. -··-----·--...... l"--.... ; - ' ----+·--+ .. --'"' -·--4-·· l • . . • .. __ • -I -. ----t-: ----r----..... ------1---·--+ -~-~-=-! -.. ~ :-~~--.--:-t-:·f· : : . :-:--:--~--~ i -. .; • -·-+ . T . . . . ; 1 l ...... ~-~ --~ .... -i --""-.'!"'"-.. .: t -~-~-...... . ·-~ -· -··-·--------t ·---... ... ... --.. ~ ... -.. ..... .. ... -,_.,. ~ ... .. -.. i -.. --,._,_.., ... _. ......... __ .. ~ ..... ~ ..... .. -.. _ ..... -,..., ... -·-···---·· -~·-··· I ...... -~T'-_ ... _ ·----·'"-+·-~ -.. ·+ --·-.... r -· ·-· ~ ---+-1 -i I l • --:_i~·-~--~-+----·_:·~i_-__ -_-_-·_·+-__ ,._-_=_:_1+: .. _~_-_-__ --+-~------·_·_=_±~:_. l ---~-----''•-----+------·-t·- -. --_-:-=-_ :·-=T-= ::·- -----·----.1. . t 1 • I ~ -....... ~-._,. ..... i ... -· ---1 .. -...t.~ ··-----· --;~--• 1 J~ • - -: = -.:. ~ :..:. ~ ~ ---: --~ ..:. .: j : ~ 4 I t • •• •• v ~ 'l ~ -+ J • •· -T·--. -·~ ~ -. / .• --" i -----~-----~·----+------~~----·-t-----4-~~~~-lr------<-·-------+-------·*·-------:-:·.1 --. ~ "' . --. j--·-·-~--:-·····:. ·-··· i . --· .. . i -. . -1·-----· ------. -t . ---- J '* .. + ..... 1 -~"---·~-. ·---·-·-·---:-~---f : :_ -1 .• -. ---t -. ·--·-· ... + ·---· --- ; . 1 - -~ ··1 . --·---~ .. -..,.. ..... 1 , -----.. . . . ·-·~-1· . .. - • . • . I SUSITNA t· • • j ! -"1 -~ ·-• - 1 HYDROELECTRlC PROJECT I ~ ' ~ ...... .. ... ' , ........ -......... ~ ... . I 10,000 I ' , .... -...... • -! ' 20,000 ··i .. --r- : i. : .... STAGE DISCHARGE CURVE -"-l·"-! --..... ..t ,.,.. ...... -~ ' ' I 30,000 RIVER ~~\ . - I '40,000 14J. ~ I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 (f .") • l ' ;; \1 - .--------------------------~:--~------------------------~----~ ....I w > ~ -:=t~~ < w fJ) z ~~­~ w > 0 m < 134:-t-w w u. • z 0 ;:::: -=1-32.- < > w ..J w 0 -.• I • -• --· ----·1 ... ----. ---··----~ -----·-··-----: .. ___..,· ..,. ....: ---,---~-1 -: --,_-i_:-_-_-_:_·-_-_;-_-t+---_-'7-_-_._-+-r-. ------+ __ ....; -·---~ ··-. . ~ ···-----, -,. __ -' .;....... _; -~-l--____ .._,_ .. ____ +-----+·----.·-----; ----,·-. -:--------··; • ·-;-. ' • • • I ' --~ -1-. ~ ·--:---t ~_; l-~ . ·--~-·-·---!------ -• ..J..-! ----·. , ___ ...., __ T'----t--------+-·· --: ... , •• ' I ' ' j 1 --+~---f·---•-_ .. , ---t-.. ,..~:-r. . ! _.._ __ __. __ ----..----_____ .. -"t------,._..... ·-r---'T ,-1 . J ---·---:-~-----. __ .. ___ ----' . ' .. ~---- .; -----1 ---------~----·.-·-+--·. ---~---·- ----1 --·-·--+----· +------ . -----;---·--·----'t I ----·-~ .. ·----. i ---1-·-•-----t··------·-1·--···--T--·--· ·--·· • ___ -_.J_l-___ -__ --+_·---~~=-~+-·-·-----t----~----·~:=====~---~---·--~~-~----·==-t-------r----r------~-----------~---~!f---·--t-----+-·---t --~ -'! --··· ~ ~:j -:-=-= =-... :-___ .:. t ·: __ ---------~ ---·---~-=---_-_--:~~-==-:·:_-_ -=-; i I ' • ' ·-'· ----+---·-·•----------·•·. -·; ---. --· ~-:---: ··---.' . ··-·--;-- t - . - -1 --.. . ·-----·~ -----.. --·--------.. --_____ ,. ------.. --..... . -·---.. -.. ----T · -.: -.. __ j ~ ~ =-r-_:: · :--==-~~~=--______ 1 _____ ------l· ... • ----~ • • • ---· -• -I ' 4,. . . ----.... -.. ~-·-.; ••••• __ ···--I --!-··---"7-----~-, -' ------------~-----~~~---+------~-------~-------~.-------t------~-------r------;;----- i ""'.,.__ .... --------------.---·-~ -·---· i ' . i -···---·-i ---·· .l ' . -- • T • ' ' - l ___ !_____ -----.:& .... ·-----·-·, -----------. -----.. i .... -:..------r-----l--------"1 _, __ J __ ··---, ----...! . -· -----1 . -----: ------. ----- ·----~----- ~ .. ----,.·--- -.. -v ·"" . . ..... ~ J. =~-7: ~-=-. -. .( ~ :. ~ :. ~ =-=-. ----· -----.. . . ... -. -"'' ! -----i I ! .. --~ .. -. --·--·---· "1 -----1- I ·• ·-· ----~-·-r--~ . -%-~-~--. =-·_· ... :· ~= = :. = t --·------~ .. ~-'T-------..... -. ·--= ·-± ---.. . --t ·--------J • -• ·-----.......... ·---- -... - . - ' 1 i - : . , , I • - .. -- .... -~_:z· : ~ r -~~--=:L~~ =-~:~==~~-=--~~ ·-:~_+·=~-~=--~~~~·~ ~=D~~-1 • ... -,--· • • • 1 , ·-I • ----4 -• ·-.. i ----~~·~-·--~·------~-~1-·-----·~--~~·~;-+·-r_-_::--_-~-~--r---~~T----+~~~-----·,_ ______ T--·--1----~~ -:---- _-.?(:-·-J ~ _··· __ : _·.,_ .. i--.. --r-...---~-~· ·-;--..t-·--... ·---~ ·-·:i . .. . . --• .. -t !..-.. ~ ••• -.. -.. ,. ~ ~ r-, .. _.,._.. -! •• ---..... --. . -·-• t .. -~ ·-,_,:._..:. :.._ ~ ~ . . -; ·----··-. . 1 .. ---. -· --1 . : 1 • • : -·. -.... --- 4 -• ~-............................... . - -., .. ·-· ~ 1 ~-: ~ -1 -.... -· 1-· -• -·-1 - -----... .,. -- I ' ; • T·:=·1-• .. ]'-i .... -. --__ .. . ----t--·. - ~ ---·-·--- SUSITNA HYDROELECTRIC PROJECT • ----1' ·-.. -. -.-··l -· . -.., . -·---;- --.... '"I ··--···-..... ~ --· ~--.. - STAGE DISCHARGE CURVE \_R_~-5~ I '! ! ..J -· 7 • ..,_."t-.: -.J 1 -- ..... -,l_ ~ -·-~ :. H :- ' : • • ...! ..1. I I 10,000 • 20,000 30,000 RIVER MILE I '40,000 I so.ooo DISCHARGE, CUBIC FEET PER SECOND 80,000 HARZA EBASCO JOINT VENTURE OCT 1983 0 [ >) .. ' , • r -' ~ ~ • . . ,---r·--.---,-,, --.-,-,-,-~ .. i . ' . . T -,-~ ---~-r--,--,T-........--,--~-r . . . I I ,, ! r· • : l I 1' t ! 1 ~ I I I I I ' • • i • • . I : :· r I I • I I ! • ~ ~ t f : • • I • J • • t J ' 'I i I • • f • I f- ' ! • • • • • ~ • ~ * l:: .. t I i t~.t ' ' l t I t t I I . ' I J I I I ' I 1 f .. I ' f I I . I • t l ' I I • f I ' • t- 1 ' I I • I t t • l .-• I I f ) I • I ' -t • • f • ..{1 :-; t t·~ ,.;.,...--·-; ·' • • • 1 ·-~,-~·-·' 1 ~ • ·····r ~ • r ~ .... ., •·r • • • .,.j • ·• ··•-r rr·~t .. r --• ~,1 •-tt f t • ,,,,. tt •t 1 • •• ~'; ; . ~ I I ! i t' I. f I I t t i ': l 1 I 1 1 .. ', t I i ' I I r I I I r • I ! I I ; I I l I i ' l I i ' • i ' I 1 ; I r I . I • • J • • t ! ; l I ' I t I ~ I I J. f ! • • ; • t • .. l 1 . ' • : r r I I • : I "! f t t I t ' f ., • t I ' t f t • t 1 I ~ . ~ t f I .. I t ~ : I t ~ f t J ! t * 1 I ! • 1' 1 t 1 f t ,. f ' •~ ' t r • I t 1 j t • t • I 1 t f t I I I t t ' ' J • • I I 1-I I , .. t • • .. • I • J • I ' • • I I ' I ' I I ·I ' ' I I ! ~ • t ·;-+,1· -·rr·l--rl ··-:··: ~ . ··~·-:· ~-:·· -; i,.· ~-:-. ·;-;--; ~-; ·:-~··,·. --r·;.· ~ 7~i. -~, rl I r-"1--.-~-.. ' . ' I . ' I . . . • • I . t . I I . ! I I I ' . I I ' I ! I ~ I I I I : I I ! I I I I I I I I I ' • ! : 1 1 1 f I ; · 1 I I i I · 1 1 : r 1 1 I : I · I I lr · .f 1 ! 1 I • • r • I ; i 1 ! • i ; 1 1 • 1 ' : ~ 1 I 1 I • I 1 • • ' ' I : I I ! . " I l I I I : • I I f : ' I. ! I "I ~ : f I' 1 1 1 r t • 1 1 t ! : 1 : 1 • t 1 ! · I I ,. I I I I ' t : I I I I I I I I I I' I 1 , , I I. , . ,_ • I; I r· i i i, , I •1. • !I ' I • -r+·tiT"!' 'l'-t1· ; ; i I I I I I I ~ ' I . . I . I I I I I I I ~ ! I I I I ! ! I I I , • I i 1 I I 1 , 1 r 1 • • t f f I I I . I .. ,-~ ~ I I I I I 1 I j I r Ill -~· r I ,. I I I: I ,. I I I :I I I .. 1' 'I I I .. r. I I I I I I • I I I I I I -1 + I T 1 -1 I 1 1 ! 1 1 I i r 1 • I 1 i i 1 r • l t-1-·-· ~ ·r · -t-~ 1-·, J.t, ,--1-T Ll t-· i.., · -:-.;...J ;_-TT'·•-. --rr- 1 . . I· ·I· I I I . I I I I ' I· i I l : I t I I I I • I I 1 t I-t i t • I I l t I I I I I I I I I 1 I I : I ·t I I I I I ! I I I t i -j , ! ' 1 I r· , 1 • 1 1 ; 1 1 , , , • : I 1 1 • 1 , 1 : , i 1 t , 1 , 1 1 • 1 • , t 1 , ,I I-~~~ ljl' ljl~ ,·;it '''I ·•~· r' ir! '''I II' ,lit~-··· I I I 1 t t ; f I I : i # • ~ I I t I rr'l·-1,. l~.r]·f--j-/llli-ITJTTI· i l --;I_ -,--.f I~ '"1-f I . . .. ! ; I I 1 ~ I ... ' .j. n I I . . II ! I ; I I ' ~ I . . r I ' I f ! ' ' I ~ •t ' I . I ' . ,. L ·I ' ! ' ' I ' . • ' ' . . • I • I • I ' ' • ' • ' ' ' I .• I I -r·-r--r· ·-r-t-r r-r ' +-,......,-.- . I I I ~. r I I 1 T t t ! i J I r I I I r I I I t t ..... ..,.. ltll -+tll 1·1~· 1 1 ! .!·ii i'il1 -~ 'lj1_ jl-1! 1ft; :r f·r·t-t . . . I ·r I I ~ ! t I I . 4. ' ! I I I I I r r ! f .,... 1 j I I r I ~ ! -~ ' . r· i • I l I ·l 1 I i ~ t r i I i ' ' • •+ • ~ <( z .... -en :::> CIJ .. : I U-W I • I I , +-i I I I I I t .. ~ I ' I I • I • t I t t ' t t' "'1 t I f' t 't-r--T-• •·r i· ! I ! : J 1 j I 1- 0 w .., w > a: :::> 0 a: 0.. ,0 a ... 0 w (!) ~--a: t-o w ...J w 0 a: c > :X: a: < :I: 0 (/) -c w (!J Cit 1-- (/) w ..J -~ a: w > -a: f I T-T. . . ' I I • l -r I f ·-r I' • I I j • t· ·1 t • ,. 1 • ; -t· I t I · I · I , • r +-fif' --·1 -t • t i' • - 1-ri-t-. . . -1---t--r"-· • I j i • ! ·I -~ r • • ' •I I I I 'T t t I .. -· . ' f I , • • ·1 i r '! r : ' t ~ t t 1 .,. r t .. : r t I • t 1 , • • -l ;· ·r I ,. r ., .• J i t.,.. t ' i-t. ... ~ . ir 1 t ···r~-1 •-1'' I.; • I -1 I t · t . -i ~ ·f ~-.,...,.. -r-r• -r-t .;_; ..... ! t ! t .. • ... 'T"'-'t ' .,. f' •J-$-~ 1 tt'" ~~~ t .l t" I • t t .. ~ -• ' r ' •• f ... "'! t• ... """ i , ~ , , r t , · • • i •· ., t i • , , • r • • 1 , ~'""' ~1 ... .,. .. , t ~ , .... " 1 t .. , ~ .... lt,r •· , ... , tt.r--.-·.,-#+,., .,.. ; ... " ;.~, .. ,~,-·1 -• .,,,t -··r ... ,t, 1: • ' • t . 1 I I I i I f i f I 1 I f I I ' ; . f I ~ I -:.. t 1 • ~I • T 1 , t ~ t t ; r .... ·r ' 1 f t-• r t .. r ·t t t t,;, 1 1 't~•r·· ,, .. , ., .. ,, ......... "1 .... ,. ~~. ''!"' ~, •. ,..~ , .. t•tt ,~··· .. .. +i • , • I t l ~ I ·-r+ . ·rl--;, .. _,__ .. 1-;-.. ·r-t-.·~· ·t--r-+-.---;-.,.. ·t-.. ---.-·..-...--·~·T"' ..... _,.T.·r-l .. r-· ........... ~-+-....... -.-T·I' -·-···. '-·, •. I . I ' I ' ' I • I . -t , , , · f • ,, 1 1 j 1 t J , • • , 1 t .. , , ' • i .. • • 1 t t , • i t t f ' t 1 , 'T t r t ' ,. t , • ' .. ·r ' t ~ ·1' I I ,. 1 ' 1' I • 1 i J I 1 I 1 i i :~ t ' i ; I 1 • ' · : t 1 ' ! 1 j i I t ! r r : • t r : !· 1 1 i ! 1 i • · f • · 1 • 1 1 1 r r 1 1 1 r , 1 • t • ! • 1 1 , , • • , ! , 1 1 , , : , 1 1 1 ~ 1 • , , 1 i , 1· 1 ! 1 • I • • • ; I I t I ; j ' f I ! • • I • ; t- 1 N -r .. l I T 1 a::) .~-;) .t . \. .. j r ·4') r·~ "'> r·.c) 1·-.t ) T i' :..) T CG 0 0 0 .. 0 ~ 0 0 ~-o .. 0 10 0 0 -o .. 0 .. 0 _o 0 ... 0 ., 0 0 t-o -0 "' 0 ~8 .. 0 .. 0 .~ r2- t:::l ~..::r r-c-L -c--l--· 1 .··) (·...._,j {",l 13A31 V3S NV3W 3A08V l33:J 'NOI!VA313 r . ·-L-L--- c z 0 0 w 0 a: w a.. f-w w u. 0 ... ill ;:) 0 -w (!) a: < J: 0 (I) Q --~------~-..u---..--.--~.-........ aa._ .......................... ._ .................. _. .... ._ .... ~ .......... ._~._ ... ~.. ~ r;;;:,.~.r,·;~ ;...,.· (~Pi"'~"'"'\ "'""';"'. ( -~''T'"""-.. --.·· ... .., ,.,.~t ·-·~r :: J -· "~""'':l'!'::·~!r-,·~---~3 -·~.. · p_::::r·=~· "'~·-"""' "'="'!: .. "1 J l'f;:'!: __ £ .• ,.. l ' ) ~~ J --·.··) ., • .,it. ~ '-~-'<'. "-;::;;:::::.;r"· .,,n m ,;;._, '~ "" •·• ~">"-~-" -"*~" , . .........,__..._, __ , "·~ '"~"C·'··-. . ..,..~H?.~,o<: ,, '·· I ,·,'·· ~~- .~·",~;+~--~~"'~--·:' ·; ' "'' ' ',' ,.. . ~~~·· k rttr-····iliiM····· -· ...... ~·~ .... !01' 'tltr.lfldr )'111-a-uJ< -~.l _ 1 . ' • r ~ •• I I i I ; I '1!' ! ' I ~ f I i I 1 l , J l L-. I I I I . f I I I! I i i: I ,__. ' ! r r ! ! t : • , ,n. ·-~" t ........ ,... ~··r---""'' ... ' ......... ·t-, .. -,...·~-·-· .:;,.--'l : ! ! -f t t t ' t I i t f 1 t t I I ' ! . . I ' ; t J l f f I ! II I , . I 'I I I l I l ' I y .. , .. 1 -~ +·: ~ I ' I ' I T I ' I I ' ~ ~ .: ·~ -r I I I I I ,, I I I I 't ;• t ,_ • .,.. ~ 1 11 •• --. r. . . . . :f€1 i ! I I l I • • I I I I : I j I I I t"rilt ~'1' 1 .. : ,,., ~~~~ !'l'!t··'l:'''lrl'lll't'''·· fl'-1 j it; I ,1 ! 1:1 11 )11 t f r t•t ttt I'' ' ' I I I I I , , r t I '. , T! : .. I : • t I ! I I ' I t r·r•.,.... ; ' ' i ' I ' ~-r ,_ ... "'" I I 0 I I ! I I I r-,·· t· 'I j ; I I r, : I ; I • I . I ! I I I ; • t ' I , ' . ~ ' l ! ! ; I ! • • i • t t· • 1 • t I f • f j ; I t : t I t i , • ~ ; . • t , • , • • .. I ., ' ' .. , • .... • T , , 1 r ~ 1 1 ' I ._ I ' J .. , f • • I l • • , I !. I I I I''! • . • I II' I • : t • • t • • • • t • I ~ I : • •I • • t • • . · ' . I • , ~ • ·1-+i · ·-Tf-•-r -~~·. ·-T· +..-. ·.-... ··;-· .. ,. ··· ·· .... -·. t· -· i-·...-!·-.-'-~ ·--~-,·---~--,......-,.. ·rr ' ... -_,.....,..... I ' I . I • • • I • I I I t· I i I I I I ' I • ' ' • I I I . i ' I I I I I t I I • I l .. I I I 1 ,,. ! I I I I 11 i · I i i I ! ' : ~~ I r I I i l 1 · 1 I I I : " I 1 I l' i I l I I . l I ,. ! I I I I t I ' ' I I I ! I I • I I I I I I '.f r I I I ! ! I I ! ~ i [ ' . I I . . . r • ' l ; I 1 ' ' ! ; I l . I I : I I I . I I . . :·•I l ! !!l•IITTil'j,l ~~;:, ll'jl ,::;;!;.:: lrtl I''' II'' ,!l'' rlri l·l i ' I l I i . . I . ! I ! f j I .· i ; i j i '· l i I l . . ! j ! I : I I I I I I i i I ! . . l l I 1 • r ~ I I I I I l ' I I • f t· I I I I . I • • I I I I J ' I I I ' r I I r I . i· . · I 1 1 1 r I I I l ; ; · I i j I l f i I • t : ' ! r · j I r I I ~ I . I r I· t t-r . ' . . -~·· -n· ~i -t·l· r T l'l"! •I I H"i---~·-r--r·r r-r '! -r· . I . _l .L.:1+ -1 i -rr ·rt· I + ··r· +11-i -r--r • . ~ 1 ! , 1 1 , : I • 1 , ! 1 : 1 I r ! ! I l I ; 1 ' 1 1 : ; 1 I ~ 1 . i , 1 • ~: -I 1·11 !'I ''lli,:ll li'l t ;! !!t! .If! 'ill jill 'Ill I' : · I I I I · 1 I 1 J r r j · 1 ' 1 I 1 1 I I' I I • , 1 1 j 1 , 1 • I l i I I ! ! I ! I i : i I I I I ~ : I i I ' : i l . . I I i f I I • ' t I [ ; l ! : <( z 1--C/) ::l Cl) 1- 0 w .., 0 a: 0.. 0 ~ 0 w ..J w 0 a: c >-:I: w > a: :J .o w G a: < :I: 0 f/) -c w (!) < 1- CIJ "' cD ~ tu _J -~ a: w > -a: • , I I I • I ! I I ' I ! ' I ! ! I : ' ~ I ' . , • I I . ' , ~ • ·~ . : ' . :---r --.---,-~, r-~r · ·· -I 1 ' 1 1 1 1 t : 1 : ! ! t ' ' ' 1 r · 1 1 1 1 t • 1 1 1 • r • • • , 1 1 t • 1 I-f· 1 1 , r· , , l · I I 1 I ! I I 1 , ; I ! l · i i I ' 1 ' i I i , ! l · 1 1 1 ! 1 ; I t r 1 1 1 1 r ' , • j· ! . 1 • 1l. i r ,. : ·•· • r l-t' ! I ' ! I I I ! ! ! ! ~-~· I I +-r--t-1 I I ! ! I I I I l I I I I ! ! I ! I . 1 -1 1 , 1 , 1 , 1 1 , 1 • 1 1 t I , 1 1 1 1 ' 1 1 1 . ; ' r · 1 , 1 r 1 I ! 1 : ..... · ~ • 1 1 • 0 0 0 .. 0 ., 0 0 '-o .. 0 ., 0 0 -o ... 0 ... 0 _o 0 • 0 Co') t~ LHl--·+1-r--l +t-·-1-r.L. T t··· r: . .; t-:-t-L '1-i..L. -rt t-J--:--rl i·· rl-·.-H-m -1--..-! •• I ! I ! I I t-rt-~ -.--f-+-t .... ·-t-,~· I . t ~ r I I . I I I r I r I I I \ I I • I l 1 1 ! f t ~ I r I f I I . I ! ! I I t t I . I 'I ' ' ' . • I I I I· i I • ~ ..j I -~ t ' • I ' I . . t I I . l I 1 ' I I I. I ' I l f I 1\' . : I· ~ 1 t I I ·t I ! t I • ! f I ! t ! I I f , I -i ... . • I ' . l f I ' • r I I ,. I r • I ,. -· . tj rrl ll'l lji lilt '''I •1 1 rttj·lf1: 1111 t 1 tl ''I'·~~· f•t• 1'!1 •lt. ·•t1 ~ .. r• 0 I it • I I I I 'I ' I I ' ' I I I ' t t I I I ·l I I I I ' r ~ ' • I ' I i i' t I I j I l . r I , • I I • t • I l ~ .,. I I •• ,. • 0 1 • * 1 • I · ' t ~ ; • ~ r 1 1 ' ' : ~ l . -.I I ! { ! I ! ! ! . ! ! l\ ' t-~ . I ! . ! I . . . ro f • • I I I r I I ! I I I I '1 I I r I i I • I ' I t I ''1 -T 1 ' I , f t I I . r -1 r-. t· r ,. • .. I . I .. -I I I I I I I : I 1 ! • • I I 1 ~. t' ,. ' I I ~ I I I l . ! t f I I I L r l-v I • • I ' t I ; I .• i • r l .. ; .. 0 ·-I ! t . t II r I :· I ! I I • • : • ! 1 t : . t .• i .. t : ; I I i ~. ~ t i • ! J. i I I I I i. ' f '! I -r r ! •. , t : ' r ' .. , ~· ~ . r-I '! • N I t ~ '-·! : ! I •. I I ' • : • ' • ' f •· ' I t ~ • I T 1 ' I • ' I • ' I I • t t 4 ~ • • ! I ' I .• i T ! I ! t I . • -t· I t t ·f ~ ., . ml -1-H-y-r-t-·r-H--:·f-.-·-rr-~·~-t-"t-t-•--r•·-r··• rm .. ,.. -r-rt-r .,..........,-.-.....-, '1-'"Tt---i-~-r--,-,.,.-.-_,_,_,.. · 1 .. ~ ·1 I r f 1 I' t 1 1 , , : 1 ; , , '. , 1 • .· 1 · , 1 ~. • , .. , t , 1 , 1 r l 1 , 1 I , 1 . t •• ~ ... I , • r . , . • , • 1 • • • ~· , , • • --r·t I I I lj 11'1 tlil ·1~, 1 ~1 ·11': 1!''' f1-fl J t 1 ! :r ·rrt"~ tlr• fl-·'·~ 1 1r·· ..... ... , + . tr 1 ·~·t :;!~ 1, l· .• '~ 1-·t~ rl~!. lr rlr! •·~·t l1f1 ~~·····ll: -· f ~ I • ! : , ' I ~ ~ l • ! I . , • . ' .. r .. ' .. r t ·f t , ' ' ~ ' J t • J.. t r ' , f • r t' .. " ' ~ • ' " t i'· r !" • ' ., .. w • - ; · J ·· ·I f. ! ·! I 1 I I 1 : t ·I : ! 1 : 1 ~ -i 1 • 1 • • • r· 1 1 •• X' 1 • 1 1 1 r r t 1 1 • ' I ' 1 '! ·I I I I ! I I ·~ ! I I I I • • 1 '. f • • ~ -~ ' ·~ •• ~ • • • • • • • • ' • • • • r 1 ' ,.. t ' '1 ! ! I ! l I I I I I I I I I I • ' I • • ' ' .• • • ... I . • •I • I I . I • • t • ~ • 1 : I f ! 1 : I i • t : I : ' t • I • .. l ,. .-# t t ., • ... ... t l ' .-• t t ' : -r+l· t:·r-·~·~r,--T-1-1 IT '1'1 ~'I' r rl r~· . rT; ·:·' ·;·7;;-T~-;; ~~-:-. ·:-~··T -~~-:-~ · t r t-' • , t t . J ... , ... ! . t ·1-. i .... r I · f l T I I 'I • • t j ' ' ~ 1 • 't" ..,.. ,. ·-r- ....-• I .... 1 ... • I t t I I I • I • "'1 t ' I I t f ~ f 1 I 1 t ! ' ' ..---..-.. f I I r ' t•••'ljt'''i''•t ,, ... , .. 1 t i' ·j I 1 1 J ! · I l ! I I 1 1 I t t 1 t ! ! 1 · ! • ~ 1 r 1 1 I • I I I ! I I ! ' I I 1 I I I t I • I • ! I I I t I • I I ! I I I ~ t I t • l • t t • ! T C".l ~ J .. C::> L.!) r.:- I 1 I l I ! t ! ; I I I I '"'-t ...,.. . .,. . .,..-r-r -~. r-·r. ··t-~ -·-·r • ., .. "i .. ' .. ,, ... ,.,., .,,. _ .. ,[,. .. I I 1 • : ~ 1 I' i I ! ,. i . ' . • I l • f • I i I ' I I l ! I I I • • • • , I I , t • I t r I I : I t i 0 ~g .. 0 .... 0 ~~.~':'t"~--"111t """"'(.,---~'''~ _. '· ~ r r~\ .,-:' ~ ""' ;•-l ""' ~ .. ..-""'~··~ ~,,,,.: "'-. ·~ ' l ., -~ 4 ' 1 -\, ~"1-"1<-~._,..:~·":~'e-~-~~--r'·-·i"""'~~-~·~~""''""7 j ;::sex $J § X1.":-'""--:;,-~:_"":'Ct""'"' 1'!'??5!l!!!&"'"r'''f'"""'IN!!!!!!I!III!5b, M·• ·:;-~"":tt.._, ...>-• ~:,-,-• ·~~~ U.,.._._, .. a· 11 C::" ~-~ 'ill; j c z 0 0 w Cl) a: w Q. 1-w w LL 0 -m ::l 0 .. w CJ ~ < l: 0 0 0 j .i c.~\ ~ 1 1 r .. ~~ ~ ~ I ~ •1 ! j 1 !t ' ~ I" ·~[ ' j t , I il ~ ' l 1 I ~ ~ ' j 1 I 'I 3 ~ ) 'I I l ,, J !j I 'i j !, ~ ~ ~ ' ·~~Ji /1 I ~J I ~ ' ·....AI ( J ! J ·' I ~ !. •I I l) ,, •~;.;iii I u 7j_ 'l -Jw L 7loO,- ....1 w > ~758- < w f/) z W<~.~- ~ ;JJJ- w > 0 m < r:-,· jl-\~--1-!...J t w w LL. . ..., . ). ...... -; ... }J 748- 0 ~ . • ..;.... -""· .:__j_-l----+-.-f !. ' I -_,_ --~-•· • ·--· -c ; .. -~~ • " : ' : -·~. -• -·"'----T--... : ·-• . -' ~ . -:.~. ::..:_ .:..~ '.. ~~~-.r : . . -~--...;..~---:r--_..., -·-___ . ~ -·---------i·..;.:·--+--t----·-· --·'------~ -----~ -~-t----..i . -·------. :- . -'1 --. -----------1·· :.=·_:J: ~ ~ ~~ .. : ~-=J :.~=-.:.:.:=-T=-==-~ ·==~=-: -------·· ~ . --- --· ~ • j • ---J. ---.. --r-... ~---· . '----..... .... I •. l . --·: ~-==-,, :.:.:·: _:_::_.1.~~ -=---..4 .. -·-···--·--· .~-. --- --. '1---. ....,.--~--- .~ : . --. ,v· . -. k?.':-~ - • 1 -~· ... --..... -------..... --~-----t--·---• -·-·.,-··· • t I l · . ----i. -,., ___ ' ,. ··---. -·-;--·--· ---·---1-·-: ~--... --.-.J1.-~. T 1 " •·-·--~ ''""7··--•-·--·1--···-··-•··-r--•·-•-•-: • . . --l . -~ -.. ---~ . - . -.. -... -t------·--t----~=-· ~ -. ·.~·-·_·_·--+---~----_-=--·-~f. -~ "1' -__ _....., i . ---. _ _. ~--·-·-:.. . ...,-.,. --t ·--~-I ;,:Z:::! . .. .. ... . -...... § 1 1 ... , .+.--1 .. -..&....-..... -t--.;.,__ ---~_..._-4 ·-----.....__--!--.. v----~ -! ... _.,,.,_ i --. --~·--1. -· .-.... f-··-...... .f------. ---·~-·--/ -··-. ! _=_:=_.:~1_._: __ .. _·4 _-_. __ -_+-i ..... _"'_=-:..-_·+---· ~ ..... _.-_. ::__-_._-_·-_· -+·-_-_ ... __ .... :;;·:r'-Tc::-_---_·-t ·_-_· _~-__ -_-!..1 ----r----r---__ --.. ~ • i.. • ---""" , ..... ~~-;-• ~ ..:."1 --!.---~:--=r----··" ------, ·-.. ---- -~-~ j ; ------~ -'·--~-·---:---+-...:.·---~~~-~-t-. ·----~--·· .1.-• --: i ~ ~ : : j"==--~1·: =-=--= -:~~-~ -=-~-~-=--=;: ~ -~~-l-·-·: :--: ·1---..;.._-·J_t _·_-_· ---;----_-_-_· ..:..-- . t .. ~. . . ~--l·--... --·$ . ..:.....,..j. ·---t--··--+~----· ·--. .... t-.. ·•. -~,! • ..,. .. --.. -:----·-----:------'"' ___ ..,.,. ···----; -.. --~-.... -·-----~ ----r----+·--·-. ----.... 1 -: . i .... ~-: ·-1 •. ~ ._.:..... ·----r-· ..._ __ 1--· - --t--·-·---·--~ • I .., --.. '1 ----1·.--·---·-·l ;__ ---V-·---i----·---·-· _ _: ____ ··-. -··· i -· . -l . -· -..!.-1 .. . -----_.J -· -----... ----+ ----· ----' - ---~-. ---~---·-·----~---. --·-···-: ----.. -·-· i --• i ·----__ ...___lr-· --·--l---·--------------·1 - -~ :-:-1 .. :-= ~ ~ :----:(--= .:=::· ;:·:·=~=-t·-----=-=~~------=-==-1 -- ,. ____ _ ·-T-. --+ ·--+ --·-·---.--·i .... --.· ~::-·: t : ~ : :· ; .. ~-: :--:-.: :-: = -=--·-t==--=-r-~== + -=------· . ....:_ i -·-- .. ----i ... 1 ----j I --r--"1 1 --. t .. - I ----1 . ---·-.. ~ ... -t .. ~ -... . -·-"1'"' ---"' .... -... --_. ... . ---: (-~. --. ...... -~·1 -·-.,. .. ----.......... -···· . -·--~---.-t·-·---·-1--·--. •. , .. I -.... -.... -, . --~--- -..;,...T ... J. :._ ··-•• -• -:"'i ·--- • ~ -• 1 ---~ -' --·--t"-. . . .l ' . --~ ~--r~ J -. ---·---·,...:-~ ------~,------~ • I I . • ... ~ .. 4 .; ~ -.. 1 "":'" "'! ~· '"""' "'T .. ..... .. ...-.. .:. ;-- .• 1 • ..: .:. ---"''i __ _. .............. --1-1 -··-i- ,.,f ,_..,.,,.,. ..~ -l '1-r_, ... .,_ .;.--"'--l-1 ..... ,, ... , " .J .. ... ~-f .. -........ f • ..., --.~. . : •. ,. : ; l ~-..!-~ -. ·-·---. .! ·--~ . . . 1 : ' ' . ~ 1 -~ ... ~ -!.. .. ; ; ~ .:. ~ !~~ .... ~ ...... l. ' . . ! ... .,.._ -~ -: -t -. 4-"''"" ... l _ ... ~ _:_ .~ • ~ ~ _, ! • -! <t : ~ .. ~ -~ . . -, . . ., --i • i . . -; ·-- 1 ' ... SUSITNA HYDROELECTRlC PROJECT STAGE DISCHARGE CURVE RIVER MILE 142.2 -. 1 10,000 ' 20,000 I 30,000 I '40,000 I 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE - ~z:i,~~,t~:~:~~--;). m -.............. ,.-i .. --------~~'-"' . "'". ' .. ~.~~.;...· •. -•• ~~~~,£;;;;,~;._.:~;:~.=:.'::':_.~~~~------~~--~-----·· ,.; 7"f rt-· • • , I I l I : I ' t i I : : I l 1 ~. 1 ; t I I .. . I I I I , ; i i ; I i 1 I I I . : l I I j I I I T I ' I • ' . t I 1 f ~-1::·· I . I J r I ' I I I , • ·r : . ! • , t I . . ' I I ' ' I . ' ' ---·-I l I I ~ t t"' .. ! I . I .,... ·~. t~---... : ... ••I ·I '! 1'"'1'"' ... -~ ..... .. ... .... • ~ r ~ ~ ~ -~ ~ P I .o ""' f .,. ., •" .... r r T ~T"' i .. "T --"" ~!:! :A-"' I I j ~~,. • 1 • I t I I I ' • ' i .. I . 1 • 1 ' I I I : I 1 I • I t • f ' I ' I ' • t-j • ' r I • t • lw, I ! I 1 1 I 1 r · I I • I I ; I ' • • I '\: • i ' : ! I I I I I " t I t " ; f . ! I I : I ; I I I ! i f ; 1 r 1 I I t I I I I I ' ' I • ' f I i t ; f I j 1 r • .. T !lli I :\ : "' : ' l I I ; i : : I . . I : : • l . 0 ; • ! • 1 i ' • ! i I . ' ! I I ~ l ! 1 : i 1 ~ t i i 1 1· .-• • • • f I 1 .;. 1 • • • 1 1 f 1 r i J I r · : . . ! ·I i ,-+-· II ,- 1 l 1 . I' I I -t ·i- I I i · I I • ! I I •· i ' i , .. , . l-1-·r-1·1-r I ' I 1 1 r : I 1 ~ f r r r I • ' I • • 1 ° I • • • • I • • • I-• • •• 1 I •• I . ; . I I I ' I ' • I I • ' • • • 0 • ~ •I!·· ,.;, r ., ·" ... •tt• !' .... ~ ·1• !lfJ J, ·tl: H +~-~· r t··~-·.--... 1 ·-... .,..~ .... :. ---·t .. ~· j-·~-t.,-:-J-... ___ .,... .. 1 ..... -r-;-,. .. r ~*··-;-r-+-rT ·r.,-· _,_.,..._ I 1 1 I II : ! 1 : I • l I I ., ; 1 ; : ! I ' I • I . . I ' I I ~ l I I l I II I 1 1 1·11 ! • .. 1 1 1 ! ! l!o 11 1 ! :I'! !I. 1 II 0 • ' I I. I I 0 I t I . I . ' I . I I 0 t I • I f I I I • . I ! ! . I 1\1 1 • l I I I I ! ! . I ' •• 1 '· I • i l • • i : I ! .• 1 : I : I ! ·l I I ,, ' 1 • , r • r , , I i . ·' II . I I I I 1 1 : ; i I ; I ; : I ' l I I I •• • 1 I t : I ' 1 j I i I t I 1-1 I t i I -j j ! t • I ' ' ' r ,_ t _r· I I I . I ! . i ~ f I i ., ! i I ! . . I I I' ll : I l I ! ! i I I . : I I I • • } I . . I 0 I J ~ l I l f ~ .. ~-r ·· --! : · I !-rr ·i ~rr-rjr 1 T I II I • • I I t i ' t 1 I · I I . I r • .. ! I I I : i I . • 1- i i i"' !. 1 r ~ ! I • I ! 1 r • i . ,. I '+f . I r : I ' I ~ ·1+ l T ·1· t ' ·-t .,. r· . II ' I t I' • r r i ! 1 r i t : 1 1 I • <( z 1-_, (/) :) (/) T -r -+-t-+-~-+--r-t-t-t-1 I I j . i i I I I . ! I ! ! . 'I· ' I I I I : I I : . ! i ! I I ! I ! I I I I I l . 8-1 I ~ I l I : : I I I j. i I I ! : ,, I I l 1! I I ! I i I ; '-~--~--~--~--iT-+-i ~--· i"'"! --~+.-· ~-,+--·-rtr_ . -:--rl 1--f-1-!' I~~ I' ,,,, 1'[1 1iTf I I till t,ll l ! t I I I I 1 I i ! • ! I· ' ~ 1 : I I -~ ., ! I ' • I I ' I I· 1'1 I ' l r. ' I I I ' ! I I 1 • ' r I t I I . ' 1 1 • t I I I ' I I I • ., 1 1 1 ! 1 . • I 1 : f I • I : 1 ; ~ ! 1 1 , : • ! . . , 1 n 1 fl I j IJ1 I I I ' I I . '· . 1 • i. I I .; i -1 ! I ~-· .. Tl +I : I I i t • t • I I t . t-1 -. ~ , • • • ~ I I t ,1 I , l r I ' I • ! j l I I -r-!-I I I I t 1-i 1 t ; ' : I I I I t i -; . ., . I I l • i I • I I •· ! t 1 1 1 1 ! r I I 1 . 1·-,. ' f • I I . 1 1 I • I 'T I i L~ I t I • . I I • T ::l~ ..... t + I I j ' .. ' .. l" • I I t • • ; ! I l i , 1 t I I • ml -rr-r -r -·r-r+--r -t -. -·--t-t'T r-rt-r-T-..-.,., + I I I . I I t I ~ I I I I I T ., 1 t ! • I -~ . t I I I I f l I i I I I t I ~ ~-l . I I i l l I I ! 0 t ~ -~ I .. I ., ~ t I : I I I .j. I .• I • ·I i ~ I I I I ·t • I t I ! • I I I I . ~ I .; I ·I t • I ' ;. • I i • ll t ~ 1-t t l I ; 1 · rt • 1 • -1 I ·• t I t t !· t -t-r-r~ I•· t•'T..,. ·•rl ! I ; t t . t ., t I I I ! , r , ., , , 1 I t ; t + l r r-• -... -. 1 • t . . • I ·~ , .., • 1 r , 1 t i ! t t-• , • f • , ! -. ·1 .. ~ . .. 1 t t • • r .. .. • t • • ., • t ; ' r " • f 1' • r J 1 ~ t· ! ~ t .. , -• t • 1- 0 w ..., 0 a: 0. 0 -a: t-o w ....J w 0 a: c > J: w > a: => .o w C!J a: c( J: 0 (/) -c ,w (!) c( 1- (/) LD . {"() ~ w ..J -:E a: w > -a: " I l : • Tl ~ I I ' I I t I' ~ ' t . l .- • I • t· . . ' r ' . ; 'i· t : ! I I ... ·t • t • t 1 • ri-t :! 11· +·-t--r • I· 1 ! ' 1 ·I -1 r · • I t I I I , I ~ I ..... •ltj ·•-r! ~-rr~ • ~ • 1 , 1 ·• r · , . 1 'T • ',I t t -t • ' ., -:-·1 J ~-r ~-• I j ! "I ·f 1 f t· -~ I •. i ! ' f '"'l 1-i "1-T : ' J • • I -1 I f-i-·i ! I T-T -~---l-•. 1 • • .. ' . t t ! I ·1·• I ~·· t ·~··-I-.t ... : . ' I ' · t · t r· ; • • · ' l :· J -' t •• "t T ... "'! T .... "' 1 .... 1 .,. -'" .. I '1· t • • .... """·"' 'f t t .. ~1 ! t t " f t •· ? I t t • ' . t • 1 • 1 , • , • , , , , t , • r • 1 , t t , · • • ~ t • : ,..-. ..,. • , , • , s • ~ .. 1 r-.. * • • • .. I I 1 I I I f I 1 ' ' 1 • •! ' I 1 • I ' J l I f ' t I ! j r • ·r ~ • I < ' '-r + • ' ; i--t-·;, r-tl r• •t-·+-r-•1-t-•r"' •t-4-..----m• -t-r ~ ,_,. T'"l"" ·r--f•.,.... ..,.. ~~..,-i--r-T"·I' -•-·t •-.· ,-f. ' • • I r • I ' • ' · I · · .,. I ~ ' I I i-1 I , ' ' t t .. I ' ' ' t t • I t t t t I J ., t .. • ' f' •• t t ... t • ., ~. 1 1 · jl•• ill! lt[t lrtf ·!ill lfi' Jtf~ tlft,!lh l 1 !• t;;·f·· I I ! I I I I I i I I ' ' I I I I ' I • I ! i I 1 f ; I I I I t i ! 1 I ; t I I J I I I • • • ' t ' l t I .. i . t I ' I • t ' .. • ~ • I • • • * "' l 1 T l T r 0 0 0 ... 0 C) 0 0 ._0 -0 10 0 0 1-0 .. 0 • 0 _o 0 "' 0 ~ 0 0 t-o .. 0 N 0 ~8 .. 0 ... 0 ~' c--- J .. c----1 c--c-- 0 o;::J S1 ~ c--.. s .. 9 _g c-c---r:---c- 13A31 V3S NV3W 3J\08V .L33~ 'NOIJ.VA313 -~ 1 \. ,, [-~ I 0 ... g r:- (J:) Li"") c- .,.., """"""~~.·~~ .... ';''!:--';"""'1: ~ . ~--..... ., ,., J "'l '1 \ ";} . \ --" 1...--·--·~-----~-~ ···---·-·~····--~····--·-~ ~ ~ ~ •··-·····W --~~c~"'*ei·~·m,..._·.·•·~~·· :-.:* j c z 0 0 w UJ a: w a.. ...... w w 1&.. 0 -m ::l 0 .. w CJ a: c: ::z: 0 tl) ~ 0 r-'~ -PHiii4ii"' * ~ 5'91' iiJI .!lot~ kW£ ['\T'?f~. '+;; >;(ll'.o:sP ¥ %9 ~·$ ···~ .i!b "':!¢1·~, 4 .... ~~~ 4 43% #Q WI :;,;s;::,;:sti!fUit$4 il' 4$111&! lf!Ji 4 4$2 $ 4 JtNjfiQUCIWIW~ ===,_ ... ,.,...,__ .. . ~ Q I I ..J w > w _. 4: w en z c( w ~ w > 0 m < 1-w w u.. .. z 0 -t-< > w ..J w 0 - _-_·-_-...;~--j ~ -=--=--·r-~ --~-r -.--··-1 ·-• ·-:-·---=-=-_:_1 ·_-_..:_:__ Bt-\\\biT =M ---.--.-1·-r·;--1--I ·-1--·--_,.-----f---·l ---·----~ .. - . ~-.-,-i-----;-~7 ! -----·-··-----., --~ "'·--..: ~---· -~ ! . ,.. __ ... -·---;.-----+----... _.:.__; .. ~ .. -... ·-;.-~ -... -· - -'"' 4 - ·--~~-= .;___ .f.-~--_________ .!_--+-1--..--~--~ ' I ' ' --••• ..,. •••••• • --·--+-. ...,...--._..,_~ .. ---, . -.. ; . ' . _._.. ·--·-----;-.. ----. ___:,__ -----t ---~ ---·-·-=-----~-----.....-1-----·-.. ---l 1"-·-~ : .. ' ----·1•---1------· !____ -. . -.. .; -----j . ---,· . -----+---·-___ _]_ __ . , __ ---! --. 1 . - ·-·--· -"t. . -· --, ---· .---·-------+ -----f--· ·-·--;------·----~-t -----:_.:_::_:-=:! ----1 -------t ·-·-· ·----·1-----___ __., ____ _ ----ii' _· -~--. _____ .1 ___ .. _ -~---!------r-·--· --4-----·-·-----! ... ---. ----· L-.. -----____ ; ______ ·-··---· ·-------·----: ~ ____ __! --.. ~-· ~J ---__ __._ __ .-!-.. _.., ___ ·--------; ---.----·--i --~-+ ------· .._ ___ --; ----·--·---,---· ·-----_. ____ -·--7"· -i·---- .. ----·i----·--4 -·-·-----··-·---------------T""------------·. ·----. ---· --·---1-----------·-. -- J .. I 1 ' 1 I . ·-... ----- . --------' . -·-··-i- ---,--·~·- ---, ·--.. ·- . --.... -t .. -.... _ .. . -----4-~---.. -...... ------~ • ----.. _ __!_ ____ ~:----~---·--_..;;.. ••• !------· --. .• -------~-··----.----·-· . -. ~ I -__ _; ___ ~-----·. ~-~--1·------1 . ---- . -~j --·--, 4 \ : 1 . --~-------------------.-----· -----.) -·----i' --·-;·-·------·-.# ... ---i -~·. -.... --- -. ' I ·-t - i-.... t .. 1 -----·---. --· =1'· -----·-+. ·---. ----.. --. , ~ J ... --·---.... --:-~J_·--···-· -·----···---_._ __ ..... ------~ .. l -----1-----!. .. --· ···-.. _ -· :~_--: ·:J.=.---.S·-· ··- -· .J •• --·-~ .... _:_ .l .. ·-·· - i ~ . l -·-·· -"": .... -~. --l -· -·-----. ---------. --·--~ . ....,...,.- ----~------~----------~~----,----~------------~----.. -.--.·~-~----------~~------~.~--~----~:-·---T ·.--.. , ' ~ ,.. I i _ _..a... .. .1. -·-_ .. ..,_ ~----"'1""" ·---~ .. ----, ==: ~ =: · --.-.-~ ·-r------· · ---·-.----~ ···-.... ·· 1 ---.... -1 .. ~ ----·~--··--___ .,--~--·--·-----, ~ ... ·I 1 ~-t·-·-· .. .. ... . Tl---~ -·-·-.: -.. 1 - J I .; ·-- 1 .. ..:: -~ l ---r--·I " ., -- ---i : ·- i -.. , . -. ~--­~·-=-: ... ~--... -··--~ . ·-..... -.. ~-i ... - -----·4--- I ____ : . t ---· -.i • -•.• ./.. . ----··--:·=:~j ... ~:;L = :-..... ; -... __ .. J -·-· =;.=~- • -· --~ ~.: -. -.{ ·-. • J • . -• ~ --- -·---/ -------·-. -:--· ----;<t1· ·--·•----· ------.. ---·-. .. -·--·-------~-----1 -·--.-"···---------r----- ---·-·-+ -------+----- ·------....!. ..,---- ---·-·+ ·---·--- I ~ ···- ~ 1 . -.--. - ' . ---·-------·• -· ...... ~ ---[X··~:::.: j. -:-·--::.-::~~:-:-.:-.=~=-~~~~~~=~: l.~'k::Q~'5fK~·-f:D. ~ -~·-.. -· ~ .. ,.._..; -.... -..... ~ - -.. --. .,J_ ... ----..... _ --·-... ~-.. ~-·· • • -t - _-_·_-_-_ .. _1~·----~·-~·~---~-~---·~--~r--t--~~--~----~~·----~-t·-f--~--------~~. -----~-r--~-t---------r---·---·-t--------·-',.·-~ ·-. -..,._ , . ·: r· .. . : ·: .l. : . -.: -___ =tj ---· :-~ -· = -~ =---1. --~ = -.-_-_-_-·.:J .. ~·~~w· ~: ·-:.::.~. _:: ~ ~ _;_:::-:.~•i * .... _.. ·--~--• ~ ---· { • .., • • 1 -:-~ J ; ---.. -I--~ -... .. •••••••••••••••••••••••••••••••• ·---_,j/1 . -·~- ·--. 1 • -• - -...,.,1 " • J ' . ---•. i • •. • • ; ., ~ ··-··t-·----·--·-r- -·-· f-· ····-- ----~~----~-----·: __ . 1 _ _ ~ .. 1. -· 1 .::-:tJ ~ : 1. : -...... -1.~.:. :-: _ _:__, :-, ..~.... ., ·-~+-• ~ --~ ••• --~ -=+. ---· -·--~ ·-~----'"""------t~--- SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE l<'A\t\\ 51£ M ~T c::>UJ\) b ~ 2 2 RIVER MILE \~i-0 1 10,000 I 20,000 I 30,000 I '40,000 I 50,000 60,000 DI8CHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 ,. f< ~ I j I I I 804.- ..J w > ~802- < w U) z < ~?J)O- w > 0 m < 1-718 - w w u. ... 797_- ., 0 -~~: =--··--_::1 ---: .. ;:...=_=::=-r.== 1. _,_. -i :· ~ . -· ~-\\\ \b" =t'5 ·-·--+-·---·~--·-· -------:~ ... .._ .. --.. ..: ··------:-_____ ]--~~r------+-----r ............ -: ----·- • ---+-~· ... ----___.. .... l. -------""·-----L-------1 . -----. • l -~~-------·~--------+-----~--4---~-----r---------~----------~----~- ---"'---.. ..L.-"'7 ------:-.. ;-----· r--;-~t------··~ ··----~ --..-~·l· .......... -~ -~~ ~ .·-t------t • • j ----..._ --•-, ... -" .. __,_........~--r------,.. .. _ T""~--"""''-r-._ ... , ~ ----1·-· ~--;------.... ! .. _____ ..:._ ---·----,-· -..................... -+·------.• ~ --·-··-r----.. -j ••• -l • --· •..• ------~---- ----i .... ~ . --·-4-· ~+-----+---t---~-·--- ---T. -·--t-----·-"!---····-·-"'"7-· -+---···- I ----; --·---4· . -----.~ -_ . ..,_..,...,_ -~ ·-- . . . ------, ·--- --+·---- . ----t ····----·-··-'--7' ···-··--·----···· ; -----... ----~·. • ; ·-....--+ . ----.. --·--~--.-·--... -----+ -·--·· ·----.... -~ : ---~·------~------~·r---------~-------~-----t-----==~~~~==~-1------------------~--­.... ....__ ---·-t--·· -·---------+ ---· ~-... ------. ··-··-!--·---+------· -·-·-...... ~ ···---: -·-·---~ -----·--~-----·-·-·---:;.,--,.C:---.. -·-.. l .. -.. ......... --;·· • T----·--·-·~ __,.,~ ... • 1 --------~---"T",! ---t---~-:-· : ";?:---k':::"-.• ~--·•·----·----... 1 .... ""' ·• ~·,_ ...... -.. ... t ~·--·-...... _ ... ·-·--· --· ... --- .i. --4 -------+-::: .. -------··---------~--.. ~ -l -.. Y-..... -/'' -2~; -_---+~---~·;/(-7~:. ------t------..J.... ---·----. ~I T • • 1 /~ : .• ~ j . -~ _; ___ _ ..-r ....... ---., .. --t ~ .. -........ --4 _ .. _ _..._ -----~ -- I • • • 1 i . . ~ .· ·. = j-r= :..f : ::: : ~ : .. "" 1 -· 1--.... -~-... ... ... ~ ... - -___ _.. _____ +-_ ---+-<·-------4+ ----.---+--- + • • '! -~-1 ----_. T - -~ --.., , .,_ -"1 • •• ---, . ... .. ,.. ~ -"' + . --y• -1' _ ........ ~ _.,_ .. ....__ .. _ ..... , ·-· ---.ot : t • •• ~ -4 I • < 1• .. • -_. • . . i .. ;--... i ... of ..,....-1. .._ +-·• ~~--""-t .... .. i -1 ' ~ . I -r .. --·--·+-----~--~~-----+-------~-- ~ I -. _ _.__ 1 - I ·--~-·-1·· ........... --;..--_,_ • -·-t ---+ .. l .. -~ ·- -i"~ ................. i . i I i 1 •. ___ ..,.___·---1------..-----·-t- .. . :V: ;~/.1 -• J . • t . .. -....... ~ •. --~ T ~. ·t --t--4: ., -·-----·---+ ... __ ......,. ... _ .... -OT•• .-... ... ~ * ·-• ~ .. !/l ___ ~~---_-_._-_ .... ~·-----+-------+-'T---+-... _-_-_-_-_t'----r----------1 . ·····t· -· --· -+ ·--.. ·-·-.. ...... 4 .. i -I --l • . ~-• l -. . 1 • -:-::-·ri -- 4 J .. .. .. ~ • ..... t • .. ... .,. .. -, , • J ........... 1 ~ .... --· ·-.. -. ·--~·----+---""''Il·•·-· ~ . +-----··--··~ -1 . . . . i ....... ---.. ...---__ .., ·-·--···-.... .. ...,..,._ ... . ... .. . ., ... < .. "" 'Oft ..f ~ -·-.;. --------~----+-------~-------;------------- • • 1 -1-:{:: .: : SUSITNA I I 1 HYDROELECTRlC PROJECT -. .. . . . STAGE DISCHARGE CURVE . ---:--...!----·- • ~· i .... "'! i • ' .,..._ RIVER MILE f • ....; .. "of .. ~ I . .. I 10,000 I 20,000 30,000 I "40,000 1 50,000 80,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE L i 'I ~ • I ij t n ill ~ ~ I I ~ ' I ·..:. ·-' jl. I ' ..:.. w > ~ 1.3~­ < w C/) z cr:: w <13~­~ w > 0 m C( 1-w w u.. .. z 0 ~2- ~ tBO- < > w ..J w 2lto- 0 .. -----*! -~-: ---. ---4 ·-. +·-·· . '---·--; .•• ~-.-.·-----I • . ; . -··-·--·--; .. ~---t-~ --·--·-----r-~ -.. ------:-------··· .... -----------4--~~·~r---~-------! ·-~ --: --· ~ .1.-.•••• .:.-.:.. -·-~-· ~--· -t-·----•><-....-··~ _=! _____ .. -~ ·-.. ---_:;_·. ·---~-----__ ___,__l..-.~-.~c----~-~...-f-----... ~------•. , . --~ - -- . . .; ...... _.: _-·-·"T --_ ----_ _:. ~ _:_ ~ --..... ........----~--,--........... -----;-. ---/ --. -· ·-·-! ---~-----~-·----~f-----..,..,------. -~ ·-.J ~.-' • - - I '"! ..... ---; ----:---+. i. -. ..,._.,.. ,___...-- ~ -t:-:-·::::-t -:: i~: -~=~= j_-_:=:: ·.:~-:_~;[6 : :. -1 .; . l ----~ ----~ . -----4 . __ :.=1----·-·i-------.··-+ --;;;r. ----·· -: l .----_ji ___ : _____ .:._ __ -i---_-_--_-_-1~! -~---_-_-+_-_-.-=---i;i--_-_-_-__ -_-1-=~---_-:_-_--~~--;;l"oll!:_;....=_· t-~-=---------~--~.----_--;{,--·------·---:-. ~---- ""--·-__ J ----· ! ... ----· ..•. ..: .. ---·-·-·-·-· -----· ·----1 -~--~ .. -• •• ---• . l ·----:--. ··-·-;·-------. • ... -_-----·-•• -;· • 1 j ----·~ _____ ; ______ ... _. • .. l -t ··--• --~=-7 -·-1·----·--------+--····· . ------____ __:__,~_ ---·---~----------. -----, --·-----------·--·-----------'-------. .. --. . -.. · " -~·-----~ - ----------·-. --· ---·-t-----,····--------~---·:---------_______ _;_ ---1--__ _! --------~--·--•.•• ------------+-----,..-----1 --f-·-----~--·-- :1· :.-::.--:: 1 =:~: ---~_·.·=-=-=-·=-===~ ~-=--=--=---=--=--== 1 .. ~--, --- . ~ -----. . . --i . ---~ 1 • • ---1-· · · . T-·-· ·--t-· ·-. -----· i --- . --;-.; -· --· . ... - ---~ . . --t --'- . -.. ---.. ~ ----r·--. ---·-I ____ , ---·j-~7-:.-. '1--·--·-·· ·-i·--: ... ~ ·-. ------i---4-· . ~-~-·-...... ---l-=--. -· -___ .J ____ -~_:·qs· ~-. --~-. ~~=- + . . t ~ ~-=-. 1 -. -~-=~ = -~ : -~--=-=~----~··:_ -~ :~ =-=~ ·-.. -· -~ : : . : _·. ~ . 1 ~-~-~-· ---i-:-. . --·-· i . --· . --·. r--·---... .4--:._-.:_:-: ·_ ·--.. ~ -. -.... -, --. ------~---··----,-----' -- -_____ +--1 _-4--Tiv:....:....;.--· ~ ~ ---i-_ --1-. -:~_ ---· ---:---:_ ·t-,------------1 • • • . ; • • -. . ···-! ----~ . . -f.-·--. . ... .. ~ -J - ---_..:_..J,ii ___ .;;,._:...,-!\--~--~--: ·: =! -:·-=--= ~ ~:-~-: =i ·:-~ :-: -·~ __ ..:..__1 ___ ·_--_--~-----~~ -1 - ! - -1 -. -l • -1 1 'T -···-------.--1 .. -. --.,.----. __ , --------------.. -- -· --"1 ... J.·-··--····--...!._..,...... .. --·-4·~--~ . .. • 1 / -----. ~ = J ~ ~ ~ ---. d" -·-· -~ : _·· ----1 --.y -·--~ -----. _+-j_-_-_-_-_ --.-~-~-=--_+-_-__ -___ -_-__ ~t-._-_--+1-------1,--------- ·= -: ': -----4 --;------1-·----·"7· .... ---.... -... , ---1 ----· ---·---...l.-·-_ _, .... ---...----------• : 1 l --1--· --.--------t ----·-·-----~~----+-----~----~----~-----+------------~----~------t-----~-----1 --•··--. ·-·-·--·----·+···-·-----~---!-·--···-····~---: -1-----=-l~ . _ J _ ·--=-~-= :-.~-=--=--=-~ ~===~: -=-=== .. : I ~:-ll"ffi:..e:~ ·. . -~ -+ -------4---•. • -. ·-~ • _-__ -.__,_·_·_-____ -+-~---------·-1--~-------~---__ ·_· __ -~l--~~----~------~--------i--------:--~---~~------~.--------7 . ~ - --1-.-----·-· -.; -----1 4 • , ,.-' -. . .. i I j • "l :~ __ _; J:·--:.~-1-·: _.. ~·=-= ::--r =:-:-·~.-.:.· -.-=-.~~-:.-~.-.-~.~.-.= •• -·.· ••••••• ·.;·-· ------~-------i--------~·--_-_-__ ~_~ __ ·+-·-------__ -_,._-__ -_-_~ __ • ·-........ 1 -~ "'1 -..... -... J ; -- : 1 -1 ... .., .. --, .. ... -i . .. -., . I 1- 4 .... ~...:.. ... _ -- .,._.., _.,..,. -....... - ...... --·~ ~ ~ ~-t--: ~ .. .. i -: -'-t -' . ~ t--., ..... -= :-~ .. : 1·: :::.:. --l------·4 ·----· ---i·-· .... ---+----- '-. -.,.~--'-..... "' ·-__ ,. .. --~ ......... _.- ----~ -..!....;...... • • i ; -~ ....1 ~~ ! ~ -..... ....J--.!. T ·I : I , • • ' , i' • '--· • • ----..,., ..... 1-· ...... ~--=---. . . .. __. ... ~ .. ; ·-""1-...... _" .... ..,_,...,._ ·-·- ' I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE LK 'l-to l RIVER MILE l 10,000 ~ 20,000 30,000 I '40,000 l 50,000 1 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE OCT 1983 .r, , f) i I ~ I I a ~· ~·· I I I I I I . J I I I ( ·-~ I -~ I ·-~ I~ P-------------~--------------------------------~----~----------- ...J w > ~ ~42-· <( w (/) z < ~ 13~ w > 0 CD f: g3~ w w LL. .. z 0 t= 5:J.o < > w ...J w ~32.- 0 1 J J ~ . • . l . . -• • J . . . '1 • • • --• I , I · · t · .. • .. ;· i .··:··· .. ,. ·_ ···j ... · . j_·_ •.. / .•. =-- --~-~-: ·-:--:-r·-~ ~~~--:~il1-~----~ ~ :·_ ~-i -~ . ~ ~-~1·---:-= ~~-=----. :r-~------ • : . • . . • J • . . -. ---+ . . '/. ' . -·-. . . . . ' . . . j . . . • • • • • • J • -l" . . . . . . --·· . . . .... -. . . ... --. l . . . . . . . . . J -. . : . -. . ; 4-' -.. -. -. . .. -.. ,. . ~ j .. -· -; . ! ---. -- -. . • : . . . . . I . ~ -~ : i : ~ -~ i : ~ . ~ : _:--= j · = . ~ ~ : · ~ . -~ . : 1i : ~ = ~ ; ' . = . : f ·. : • • ' ~ . . t' .. ' : . j ~ . . 1 . . ... : = . i :· .. ~ i : : : -. : l . ~ .... : : _i --·--l.----+-----+--·--J 1 --..------ . . • . • l . • -l . . . . .. • ' . . -• ·-. . ~ . . .• . l ' J : ·l -.. ··-4· .•.. ~ •.. ·-·-j''' ... ·j .. : ··•j ..... , ............. . ·: ···,·· ·: .. .,_ ··--··I-··1 ····1· ···---+------ • I •••·•·I, , .. ••·••j· .. , ~ . • • • . f J •• • .. • •••.• ~-.•• ~ • • • . . I . . . . j -. . . : . . . . . _--~ ·=-J -~-~--t--~ ------. -. -~--t11_~_· _ _: ___ -~--=-1·=-= _ .. ___ ~--.. ----r-~ -~~--t------~----... - . .. . ~ . . 1 . . • • • . : . -.• .. . . -.• . • l . ' . • 1 . . . . . . . . . . : : . . . ! -. : : l : . ·: . : J . -~ _· i : . . I . -__:__· . : -: -. . . T . --~ -j . ~ -. . I . "'\ :-D B,. \{ill . : . ~-;~--.. ~ _· . -~~-~J_j --· .. :.:_~t-~~ -~-~:--~:::-:-;~~--_· ·-·---~ . _. --~ ..... ,. ····· ···· ..... ,· ···-~~ i ··-i. -~ .•.• --1 .. " • ... • 1 • .. "' -• ... • . . .. ~ ! l ~ IIi • .. • ' ~ .. .. ... . ·--·· ·::. ·1. ·.:· ·Jj· .. :~ . . . : : . 1 : . : : ~ : . ·• . : . ~. . : . . :-. :--. -·~·-· --~--~--~--.. · ·-··--~--~ . . . ... . .. -~ .. ' . . . .,. ' . - . 1 . .. .. .. .. ·-'T""' ' i I SUSITNA HYDROELECTRIC PROJECT STAGE DISCHARGE CURVE \_ >;<...~ -La z RIVER MILE \L.\--'6 Plct- I : 109000 20~000 30,000 '40,000 50.000 60,000 DISCHARGE, CUBIC FEET PER SECOND HARZA EBASCO JOINT VENTURE •\ \\ \ 0 l ~ r ., • I I i I I I . I I t ' t • I I I i 'I. T I ; : : I . ' ! i .. I ! I I ' • I' • I . ! I I I • ' . . . I ·, , , , I .... ~.1111'11 .. .,,.. , • -~* h*.,... .: I ' I I : .; f I I ! I I., t : t . t"' • 1 ' . I I 1 I ' i I I I I • I t t t ' , , , . I , ' ' . ' ~F *·•1"11.?"1" ~ ~ J;t -~ rr : ' : 1 I ' . I I : f I i 0 I I ! • I , : ' 1 • -l • I • I . .,-1' t t 1 ~ t ,. t ...... -·-....... ,._ ·r ~ ... , ..... --, ..... -. .,. --~ , ... i 1 : : ; • I ~ : : I • : : • : : • I • : I : ; I I ! . : I ~ I ••'1'!111 !t!j 'I' !il~ litr ;., :!• •t• ! * I ; t f I " • .. ' I t t I ' t l ; l ' ~ . • • ! • • ~ . ... : .... -... "1-f""'" ~~~~--~.--.·~ . • I 1 -~--~+-.r~----·~~.---~~~--~~---- 4 t ' • • I : "! I I l • I • t ... " , ~ ! r ' ' i • .-• • .-r • • t ·t 1' ,-! ! ! 1 f -• t " t t-t f ! • ' j ' f I f • ' r · t • I • J '. ,.. t ... t I . .. t t .. • • • ..-•• • t ' t ; ! t I ,.. t t ~ ! f -' • ' I ; t , ' * • I · • 1 1 ·I .-r • • • • ' ~ • .. t • • • • .• ~ • t • • • 1 • l • r t ., • • • I I • t • r • J 1 • ;-i, .. , .. , -r~,~ ;~·,: ~-rr-; , ; 1~ ·:·~-··n-r,; ··;-:·r~ ,-i,r; .. ;-··:~-i-;. ;·:--i·i· ·;·:--:·:·,T~·~-~ • I 1 ! I : : • I I ! ! 1 • 1 1 j : T • • 1 1 ! r • 1 I I I 1 I I 1 j f 1 1 • I : 1 1 I 1 I I · 1 1 • , : r 1 , 1 , 1 1 , • 1 1 , 1 •1 -;~ ................... j.~:w,·; ~1 {; · i j': i; 1, .,, I I :; ~ 1 • 1 11;: : ~!: ·1, i: 1 · 1 i : ~,· i: 1 I .. I . ! I : I I I I I I • : • • I : I i ; I I I I I I 1 1 I I . I : ~· l t I' 1 ' • i • I' I • jl · 1 I • ·, ' • I • 1 1 1 1 1 1 1 I ~ I .. r'·· i,-: ·r rt· r:··· ·t· r·r j .. , •• ;.:-rj'· r~-j-i·: . --r-~·ri-tl·t! -r-i·t+ ' I r I· 'I I I I I I • l i I ! I • I ' ' t I ' I I ' ' r ' I i ! I ' • ! I I t I I ; I I I • I • I I I I • . I I I I I . I I I . . I I I • I I I I II' I ! I i I l ~ ! I ! I I : I ! !' I 1 . i I I ' ,. I I ! I l I I I • I I • I I I I I • • I • I 1 I I • ' • • ' I 1 I I t r ' • t I ., ' I l I ! I t ! I I I • ·it· f · ·: ~~ ·r ., 1 r I . I I . ' : I I ' ! I I i l ,. . I I I • • • I <( z 1--(/) ::l (/j 1- 0 w ..., 0 cc a. 0 -a: 1- 0 w ~ w 0 a: c > :I: w > 0: ::J .o . w~ ~~ <, :I: ~~ c_j w C) <( .... CD 0 -: 0 ~l - w .... J r;;..._a ::i c.c w > -a: +-t-44-+-1-+-lf--t-t-1 1-r-+-. . 1-tT ·-t-J_,........-r-+-t--;-.--;-;~ l rjl, I I i -, I I i I 1·1-, -. ~ ·-' ' ~-•• -l I ; 1 1 I • 1 1 1 , I 1 1 • • ; 1 i , 1~ • i : I 1 1 ·r , •. 1 , r ; 1 • ~-"· • ·t 1·-r ., . 'I 1 1 1~i! ,1 ,! 11 1 1 r ~';'; ; r. 1,: rlil 11 1 , :1 '· !'·•·i-1-1·-r~-, .. ,,; ! I 1 ll 1 ! 1 1 1 I! • i i I ! ' 1 I , I ! I I 1 I I 1 • t ! I'' l j 1 r I 1 1 I, , l''T" !·1 .. 1 ~ --!--;· t . -I-r'"T -• · .. · ~-· t ..,. ·-t· ·-r-· ~ • · 1 ~ -•-···t + "'i ~ ·1--r -· "T·rt-•·rr+-' ' 1 1 ·,-~-;--r-r-;--t-r I ' I I I I I ! ! I I I ! ., : .. • . 1' I ! ! r I I 1 I I • t I r I 1 I I.. I I • I . r I I r I ·~ . -I· r I r 1 I I I I i I 1 I I I I I I I I ; ; I • I I ' : l • I : I • ! l ' -I . ., . ' I I I : : I I ' I . ' ! . I I . i . ~ !' -i . • I•! j! •• 11 •••1 11 11 •1 ill' 'lj,. jt·it 1 tl• r1rl ·-~ l·-rr~ • 1 · 1 • • ~ I 1 • , : 1· 1 1 • , 1 i . 1 ;. : r •• : f : ~ • •1 !1' ··1-+ : t ' • • I f I f • I ' • . f f T-~~-r~~-+-r~T4~-r,-~~-T~-t-r-t-T~~~-1-r-r~ • . . I 11 •1 ,, 1111 !l'' II'!,,.,,~,,,.,,, ...... 1 t·r··-r : , ! t t • , i . ; ! , , r , • t , • ~ .. ~ I .f 1 • , , i : r-... • t i } -r... t !..,_ 1 ·1 1 r I i 1 • 1 1 • • 1 I • J l 1 ! I I • • ; • 1' t r r • r t 1 1 • • ! !'-'t -~-~ 1 • I : ! . I • I • : : • ~ • .. I I I . : : I ~ I. I . ' .J ·I 1 • I • ' I • I . ! i ' i-t· '1 . . I • ' f ..-•,-;-11· 'f,'I'T ·r r ;~-~ -·•-.-1··r.,!l 1 -,..~.,-1 r .. .-,--..-·-"'r--t--;'""' ,._ .. .,._ ·-·-,-..--r· f'T'-t-'l""t-•· • • • • ,.. . t • , • I ' ; ' I 1, ' ' • J -. : r '"" J l ' • I • t .. ' .. "T .. " ' ' I I r t • ·• •· .,.II • I 11 lir·t 1 ,. • ·l till l'i· 11,; !i ·ri·• :.;, ...... jl·t··-t··· I .• ~ I II J ~ : r ; ' r ; r I I I I ~ : ; I ; t I ... . ' -t 1 1.. I • ~ • t .. t r ' ~ • .. ;.., . ' , . I I l .. . .. • . ~ . t t I ' ___ ...______ : : •. : : i ' ' . , . . • I . t , r ' J ~r ' i • ' ' • J t ! ~ , ' . ' .. ., • ' ~ , r " • • r .... r· , .... , - I . . : ; I : I . I : i I I . . I I : . . ' . )<..' -, --· T I .J ............ j,· ..... ,, 1., t1~t .. ,~ .... ·li-t., •••••• ,, •i·-.,, ....... ,. .. ~~···· .. .. ' I ,. I . i • I • • • 1 l I • 1 t 1 1 1 1 , 1 1 • 1 1 , 1 : , -~ I • , • • I , 1 ! . , • • 1 -• 1 : • 1 ~ ! , • I. 1 1 1 • • r , 1---r-, • I. ·r ·I ·I r I r I I j : I I I I ~ 'I I ' ' I • I r ! I I . • • I • • • ! . ,. f I I I I •• .., l • .. • r • • • .... I • '1" .. t • · I T I r 1 I 1 1 i 1 • I r • , ·1 r , , • • , • t • -. t ' , , • t t f , • • , • • i -.. J • 1 , , .-... --. • • ~ f • • t • f i • ~,-r .... ,· .. :-rr·l-r,'· IT;,'T ~-,-: ~-I :·r;· ~rr:-:-~~;-7·:·rl ··1-r-:--:-r-,. -:--, ;-~ --~--: ~ ~ r;: ~-T ·;·;I I ' '_.,.,.. -.-·:-:-; ·r:·;~7 :;-· I · I I i 1 I t I r l 1 t 1 ! -~· • l • : 1 1 I I 1 I r • r I 1 I ' • r • • I I I ' I I • • I . I • I I . . . . l I . . I I • I,, .11. 1.1~ 11'1 :1'1' •:!• lj~ 1 1 1 I 1 1 11 I,:: lj 1 ''.' I II 1111 !··t I ~ ~!!!~" ~ ~ _j J ~ l4l ~ T g) ~ £.::511 111!.!58 I ~ ~ lllll!miiJ - l "-1 ~ ~· -~-------- - 0 0 0 ... Q C) 0 0 r-o -0 1ft 0 0 r-o .. 0 ~ 0 _o 0 • 0 (") 0 0 ~-o -0 "' 0 ~8 • 0 ... a • ~ -= .... ' . .. .• _o. c z 0 0 w (I) a: w Q. t-w w 11.. 0 -m ::l 0 • UJ CJ a: < % 0 • a ·.~ ~ co (J) ... t-o 0 l J :' .. .... • t' • • • • (; ,... o. , 'o • ', ·' j ~ j . . j l l-·~·~~ I. ,. ).l!! lcJ~.~ ,:fl .~ f;•frl ·~~ 't.~f§!. :~.::~?"(~