HomeMy WebLinkAboutA Preliminary Classification system for Vegitation of AK 1980A Preliminary
Classification System for
United States
Department of
Agricu I ture
Forest Service
Pacific Northwest
Forest and Range
Experiment Station
General Technical
Report
Vegetation of Alaska
PNW- 106
May 1980 By Leslie A. Viereck and C.T. Dyrness
This file was created by scanning the printed publication. Mis-scans identified
by the software have been corrected; however, some errors may remain.
Abstract
A hierarchical system, with five levels of resolution, is proposed for classifying Alaska
vegetation. The system, which is agglomerative, starts with 41 5 known Alaska plant communities
which are listed and referenced. At the broadest level of resolution the system contains five
formations - forest, tundra, shrubland, herbaceous vegetation, and aquatic vegetation.
Keywords: Classification (vegetation), communities (plant), Alaska.
Leslie A. Viereck is plant ecologist and C. T. Dyrness is program leader at the
Institute of Northern Forestry, Pacific Northwest Forest and Range Experiment Station,
USDA Forest Service.
Contents
PREFACE ............................................................... ii
INTRODUCTION ......................................................... 1
REVIEW OF VEGETATION CLASSIFICATION WORK IN ALASKA .............. 1
Coastal Forests ........................................................ 1
Aleutian Islands ....................................................... 2
AlpineTundra ........................................................ 2
ArcticTundra ......................................................... 2
Interior Alaska Forests (Taiga) ............................................ 3
Entire State of Alaska .................................................. 3
PROPOSED CLASSIFICATION SYSTEM ...................................... 4
Forest ............................................................... 5
Tundra .............................................................. 5
Shrubland ............................................................. 6
Herbaceous Vegetation. ................................................... 6
Aquatic Vegetation .................................................... 6
Documented Plant Communities (Level V) .................................. 7
PRELIMINARY CLASSIFICATION FOR ALASKA VEGETATION ................ 8
KEY TO LEVELS I. II. AND Ill OF THE PROPOSED
CLASSIFICATION OF ALASKA VEGETATlON ........................... 28
REFERENCES ............................................................ 31
Preface
The first draft of this classification was produced at the Alaskan Rangeland Workshop in
Anchorage in February 1976; it had four levels of resolution. In June 1976 it was revised, and
the second draft, with five levels, was sent out for review. The committee that worked on these
early drafts included, in addition to the authors, William Gabriel (Bureau of Land Management,
Anchorage), Samuel Rieger (Soil Conservation Service, Anchorage), William Mitchell (University
of Alaska, Palmer), and David Murray (University of Alaska, Fairbanks).
Many others contributed significantly to the classification. Paul Alaback (Oregon State
University, Corvallis) and Bonita Neiland (University of Alaska, Fairbanks) provided information
on the coastal southeast Alaska forest types. Allen Batten and David Murray (University of
Alaska, Fairbanks) provided a literature review and much of the background information on
the tundra types. In addition, Mr. Batten reviewed many of the vegetation descriptions and de-
termined the synonomy of many vegetation types. Peter Scorup (University of Alaska, Palmer),
Kenneth Winterberger (USDA Forest Service, Pacific Northwest Forest and Range Experiment
Station, Anchorage), Paula Krebs (Bureau of Land Management, Anchorage) and Patrick Webber
(University of Colorado, Boulder) provided valuable insight on the use of classification in map-
ping vegetation in tundra and forested areas. Richard Driscoll (USDA Forest Service, Rocky
Mountain Forest and Range Experiment Station, Fort Collins, Colorado) provided very helpful
revi ew co m men ts.
We also acknowledge the encouragement to develop this classification by the
Federal and State agencies involved in inventory and mapping of vegetation in Alaska.
ii
Introduction
It has become increasingly apparent that a unified statewide system for classifying vegeta-
tion in Alaska is needed. Over the years, so many individuals, agencies, and institutions have
described and mapped the vegetation that there are many approaches to naming vegetation units
currently in use. The lack of uniformity in the approach makes correlation of information be-
tween different areas and workers difficult, if not impossible. A generally acceptable hierarchical
system that accommodates all major plant groupings in the State is needed. If the levels in the
hierarchy are carefully chosen, the classification system should be useful for statewide applica-
tion as well as for detailed work in localized areas.
This suggested classification will be revised as new information becomes available.
Although it reflects input from many biologists, feedback from users will be helpful for later
revisions. The goal is a system that can be applied at all levels of resolution and in all areas of
the State.
Review of Vegetation Classification Work in Alaska
Interest in vegetation science in Alaska has traditionally been oriented toward the tundra
areas. Far more information is available for tundra vegetation than for either taiga or coastal
forests. The emphasis is still on tundra, but more effort is now spent on vegetation work in taiga.
Following is a brief summary of some available sources of information for use in constructing a
statewide vegetation classification system; it will give a general idea of some of the past major
vegetation classification efforts in Alaska.
COASTAL FORESTS
Little work has been done in Alaska coastal forests to describe and classify vegetation. A
good source of general information on vegetation in southeast Alaska is a report by Palmer
(1942) for the Fish and Wildlife Service.' Palmer, however, only lists two forest types and six
other types for the whole southeastern area. There are detailed descriptions of the vegetation of
some coastal areas, such as Coronation and Wornkofski Islands (Klein 1965), Prince William Sound
(Cooper 1942), and Glacier Bay. Glacier Bay has also been the subject of numerous studies of
plant succession after deglaciation (Cooper 1924, 1939; Lawrence 1958; Crocker and Major
1955). Neiland (1971) described bog vegetation but did not separate distinct vegetation types.
Because of this lack of information, our classification may need considerable additions to
accommodate coastal forest communities, especially at the plant community level. Many of the
vegetation units in the present system were suggested by scientists currently working in south-
east Alaska and are based on work not yet published.
For the reader's convenience in using this publication, unpublished references are listed with published
references in "References."
ALEUTIAN ISLANDS
Amchitka Island has been the focal point for studies of vegetation of the Aleutian Islands.
Early work by Hulten (1 960) and Tatewaki and Kobayashi (1934), however, gave some general
descriptions of Aleutian Island vegetation, Amundsen ( 1972) described ten plant community
types on Amchitka Island; a more detailed description of the vegetation was given by Shacklette
et al. (1969) - they listed 15 habitats with 41 plant communities using the system presented
by Fosberg (1 967).
Our classification system may be incomplete for plant communities of the Aleutian Islands
because of the paucity of information for those islands, with the exception of Amchitka Island.
ALPINE TUNDRA
Although considerable information is available on arctic tundra in Alaska, little informa-
tion is available on alpine plant communities. Palmer (1942) and Viereck (1962a, 1962b, 1963)
described plant communities in the Alaska Range; Scott (1972), the Wrangell Mountains; Dean
(1964), the Baird and Schwatka Mountains; and Anderson (1972), the Tanana-Yukon upland at
Eagle Summit.
Murray and Batten (1977) summarized information on alpine plant communities and
incorporated them into a provisional classification. Their plant communities were used as the
starting point for our tundra classification.
ARCTIC TUNDRA
It is impossible to review all the considerable work on classification and description of
vegetation in the Alaska arctic tundra. Notable studies include those of Spetzman (1959),
Britton (1967), Johnson et al. (1966), and Johnson and Tiezen (1973). Both Spetzman (1959
and Britton (1 967) made general vegetation descriptions throughout the arctic tundra area
north of the crest of the Brooks Range. At Cape Thompson, Johnson et al. (1966) described
and mapped 13 types and arranged the types along gradients of moisture, soil texture, and slope.
Johnson and Tiezen (1973) reviewed the vegetation work in arctic Alaska and listed 42
community types in ten physiographic habitats. They did not describe the community types
but did correlate eight major types with soil texture, drainage, soil type, and level of permafrost.
The 42 community types represent a mix of habitats and general vegetation physiognomy and
plant groups.
Hettinger and Janz (1 974) described vegetation and soils in northeastern Alaska; they
identified and described 67 vegetation types and correlated them with terrain and soil features.
Koranda and Evans (1975) classified the vegetation between the foothills of the Brooks Range
and the Arctic Ocean, partially on the basis of physiography or topographic feature, but gave
little information on species composition. Webber and Walker (1975) described 12 vegetation
types which were mapped in the Prudhoe Bay area. Murray and Batten (1977) listed all arctic
tundra communities that have been described in the literature; their work is the basis of our
proposed classification of Alaska tundra vegetation.
2
INTERIOR ALASKA FORESTS (TAIGA)
Little information and few quantitative analyses are available for vegetation of the taiga
of Alaska. The work accomplished seldom included attempts to classify communities. Two
notable exceptions are Hettinger and Janz (1974), who developed a classification for the north-
eastern corner of the State, and Hanson (1953), who classified taiga communities in north-
western Alaska.
Viereck (1 975), after reviewing available information on taiga communities, developed
a classification that followed the system developed by Fosberg (1967) for the International
Biological Program. Whenever possible, Viereck made his classification compatible with Reid's
(1 974) for an adjacent area in Canada. Viereck showed relative positions of all vegetation types
along hypothetical moisture and temperature gradients. All interior Alaska forest communities
in our classification are based on Viereck's (1 975) work. Because of our incomplete knowledge
of taiga types, many additional communities will undoubtedly be added in the future.
ENTIRE STATE OF ALASKA
All statewide vegetation classifications we know of were developed for use with large-scale
vegetation maps. Spetzman's (1963) map, at a scale of 1 :2,500,000, is the basis of subsequent
vegetation maps of Alaska. Map units shown are four forest types (coastal western hemlock-
Sitka spruce, bottomland spruce-poplar, upland spruce-hardwood, and lowland spruce-hard-
wood); three tundra types (moist, wet, and alpine); two shrub types (high brush and low brush);
and muskeg-bog. A slightly modified version of this map was published at the same scale in 1973
by the Joint Federal-State Land Use Planning Commission for Alaska.
The National Atlas of the USA contained a map of the potential vegetation of Alaska
constructed by Kuchler (1969) at a scale of 1 :7,500,000. The vegetation units are similar to
Spetzman's (1963), although many names were changed. In the taiga, Kuchler combined the
upland units into one unit termed spruce-birch forests; the low mixed type he renamed black
spruce forest; and the wet, moist, and alpine tundra of Spetzman he renamed water sedge tundra,
cotton sedge tundra, and dryas meadows and barrens, respectively. Kuchler also recognized that
vegetation of the Aleutian Islands differs from that of northern and western Alaska by identify-
ing two distinct types: Aleutian meadows and Aleutian heath and barrens.
Viereck and Little (1972) published a map of the vegetation of Alaska, only slightly
modified from Spetzman's map. They provided an extensive description of the mapped units,
as well as a further division and description of additional vegetation units.
3
Proposed Classification System
In keeping with recent national trends, we have devised a "pure" classification system,
that is, it is based, as much as possible, on the characteristics of the vegetation itself. Although
many systems have combined vegetation, soils, landform, and climate, a single component
classification has distinct advantages. Because only vegetation is classified, a logical, consistent
hierarchical system can be developed. In the ideal hierarchical system, each unit is exclusive of
all others, and when one class at any level is known, all levels above it are automatically known.
Such a system should be as objective as possible. Boundaries of the types should be fixed and
spelled out so that marginal situations can be consistently categorized by all users. Actually, it
is virtually impossible to be entirely objective in determining classes and class boundaries, but
objectivity should be the aim.
By restricting our classification to vegetation, we do not imply that information on other
portions of the ecosystem (for example, soils and landforms) is not important; in many
applications this information is as important as knowledge of the vegetation. By keeping the
classification pure, we attempt to provide the greatest flexibility and a more universal appli-
cability. As Davis and Henderson (1 976) stated, "an integrated system predetermines the way
components are combined, makes a value judgment about which are important and which are
not, and thus limits its application to only those situations it was specifically designed for."
In local areas, many land managers will prefer at least a partially integrated system. A
manager might, for example, refer to "wet sedge-grass tundra on alluvial fans." A generally
accepted hierarchical classification for soils exists, and one for landforms could easily be devised.
It should be stressed, however, that combinations of units from various classifications would
change from place to place, as would their significance for management limitations. Hence, a
combined approach, using elements from different classifications, should be for strictly local
application.
Bailey et al. (1978) summarized the types and characteristics of resource classification
systems. They noted that the most basic system is a taxonomic classification that is independent
of place. For maximum usefulness, a classification should be based on many characteristics. Our
classification is based on all the plants at any location - the relative abundance of individual
plant species. It is well to keep in mind that our proposed system is a taxonomic classification
designed to serve many needs. In this respect, it is a natural rather than an artificial classification
designed to meet a narrowly defined need (Bailey et al. 1978).
Our classification has been developed by aggregation, with plant communities as the basic
elements. We started with known communities, grouping them into broader classes based on
similarity of composition by species. Some plant communities we have listed have been described
in great detail, others in only a sketchy manner. In all cases, however, we attempted to list at
least one reference for each community. Generally, the communities are named for dominant
species in principal layers (tree, tall shrub, low shrub, herb). In some cases, however, species with
high indicator value are also listed.
4
This system is designed to classify existing vegetation, not potential vegetation. A classifica-
tion for potential vegetation must be built on a solid background of knowledge of successional
relationships of all vegetation types. Since the successional status of many plant communities in
Alaska is, as yet, unknown, we concentrated on existing vegetation. The successional relation-
ships of the vegetation units are important and will be included in future detailed descriptions
when information is available.
The proposed system has four formations for terrestrial vegetation - forest, tundra, shrub-
land, and herbaceous vegetation - and one formation for aquatic vegetation; these formations
constitute level I. At the finest level of resolution (level V) units are discrete plant communities,
with levels I I, I II, and IV intermediate in resolution. The scope of the system is shown by the
number of units: level I I contains 15 units; level I I I, 39; level IV, 126; and level V, 41 5.
FOREST
The level II classes for forest are conifer, deciduous, and mixed. A conifer forest is one in
which over 75-percent of total tree cover is contributed by coniferous species. Similarly, a
deciduous forest has over 75-percent of the tree cover in deciduous tree species. In a mixed
stand, neither conifers nor deciduous species have clear dominance; both contribute 25 to 75
percent of the total canopy cover.
The classes in level I I I are based on amounts of tree canopy cover and are those suggested
by Fosberg (1967) - closed, open, and woodland. Closed stands have from 60- to 100-percent
crown canopy. Crown cover is best determined from aerial photographs. Open stands have from
25- to 60-percent crown canopy cover. Woodland has only scattered trees and a canopy cover
of 10 to 25 percent. Areas with less than 10-percent tree cover are not classed as forest.
TUNDRA
The level I I classes for tundra are sedge-grass tundra, herbaceous tundra, tussock tundra,
shrub tundra, and mat and cushion tundra. These are generally recognized classes, and many of
these terms are already in use. By herbaceous we mean nongrasslike, nonwoody plants - some-
times referred to as forbs. We have narrowed the classification under tundra by listing many
grass types as herbaceous vegetation and many of the shrub types as shrubland.
We assigned grass meadows, except those in the arctic, to the herbaceous vegetation forma-
tion. Under this approach, all grass communities in the Aleutian Islands and Kodiak Island and
in south-central Alaska are classified as grassland rather than tundra. Common grass species,
such as Calamagrostis canadensis and Elymus arenarius, are restricted to the herbaceous vegeta-
tion formation. Grasses in sedge-grass tundra are, on the other hand, mostly typical arctic species;
e.g., Arctagrostis latifolia and Poa arctica.
5
The separation between shrubland and shrub tundra is more difficult to define. Although
the ericaceous shrubs (e.g., Empetrum nigrum and Vaccinium uliginosum) are mainly confined
to shrub tundra, other shrub species (such as Salix planifolia) are conspicuous elements in both
shrubland and shrub tundra. Until more data are gathered, the separation cannot be made
simply on the basis of floristics. The classification at present should be partially based on
location; for example, stands of ericaceous shrubs and low willows north of the Brooks Range
are best classified as shrub tundra, whereas an equivalent vegetation type in lowlands south of
the Brooks Range are classified as shrubland. Stands classed as shrub tundra, however, would
include sizable amounts of typically tundra sedges, herbs, and mosses - species not occurring
in shru bland stands.
Mat and cushion tundra is differentiated from shrub tundra mostly on the basis of height.
Mat and cushion is made up of prostrate shrubs (most commonly dryas) which rarely surpass
20 centimeters (about 8 inches) in height. Closed mat and cushion stands have more than
75-percent cover in prostrate shrubs and other species. Open mat and cushion occurs on less
productive sites and generally has only 50- to 75-percent plant cover.
SH RUB LAND
Most shrubland communities are dominated by willow, alder, or birch; therefore, level I I I
and IV classes are mainly based on these genera. Tall shrubs are generally over 1.5 meters (about
5 feet) in height; low shrubs, less than 1.5 meters. Under level IV, closed shrub stands have a
shrub canopy cover greater than 75 percent, whereas canopy cover in open shrub stands ranges
from 25 to 75 percent.
HERBACEOUS VEGETATION
The major classes of herbaceous vegetation at level I I are tall grass, midgrass, and sedge-
grass. Tall grass, as defined by Fosberg (1967), is made up of graminoid plants which are over
1 meter (3.3 feet) tall when fully developed. For our purposes, midgrass includes all grass stands
with a maximum height of less than 1 meter.
The major grass species in tall grass communities are Calamagrostis canadensis and Elymus
arenarius. Calamagrostis canadensis on dry sites is also included under midgrass because of its
shorter stature in these less productive areas. Another midgrass species characteristic of dry sites
is Festuca altaica.
The herbaceous sedge-grass includes both freshwater and saline marshes where woody plants
are virtually absent. The freshwater marshes that include a substantial component of shrubs are
classified as shrubland.
AQUATIC VEGETATION
This category covers all plant life in permanent bodies of water, whether they be streams,
lakes, or ocean. This category has not been developed in the present classification, and much
work remains to be done.
6
DOCUMENTED PLANT COMMUNITIES (LEVEL V)
Under level V we list the plant communities and references known to us. We have stand-
ardized the community names by listing only the most significant species. Species in community
names separated by hyphens are in the same layer; a slash between species indicates a change in
layer (tree layer to shrub, shrub to herb layer, etc.). Some references listed for the communities
give complete descriptions; others mention only the community name.
In many cases, elements of higher levels can easily be combined with community names for
greater clarity. For example, a Picea mariana/Sphagnum-Cladonia community is listed under
both open black spruce, and black spruce woodland. In actual practice, these communities should
be referred to as open Picea mariana/Sphagnum-Cladonia and wood land Picea mariana/
Sphagnum-Cladonia, respectively. This not only differentiates between the two communities
but also provides more information in the community name.
The provisional classification follows. Nomenclature is standardized to Hulten (1 968) for
herbaceous vascular plants, Viereck and Little (1972) for woody plants, Crum et al. (1973) for
mosses, Hale and Culberson (1970) for lichens, and Worley (1970) for hepatics.
7
Preliminary Classification for Alaska Vegetation Level I Level II Level Ill Level IV Level V 1. Forest A. Conifer (1 ) Closed a. Sitka spruce - occupies wet sites in southeastern Alaska, Picea sitchensis/Oplopanax horridum- Rubus spectabilk/ forest conifer primarily alluvial flood plains; occurs as a narrow coastal band in south-central Alaska and occupies much of the forested area on Afognak Island. Cornus canadensis (Alaback 1980, Neiland 1971, Stephens et al. 1969) forest b. Sitka spruce-western hemlock - occurs on moist sites Picea sitchensis- Tsuga heteroph ylla/L ysichiton americanum/ Sphagnum spp. (Alaback 1980, Neiland 1971, Stephens et al. 1969) Picea sitchensis- Tsuga heteroph ylla/Vaccinium ovali folium- V. alaskensis-Menziesia ferruginea (Neiland 1971, Stephens et al. 1969) Picea sitchensis- Tsuga heteroph ylla/Moneses uni flora- Tiarella trifoliata/Mniurn spp. (Neiland 1971, Stephens et al. 1969) throughout southeastern Alaska and in a narrow coastal band in south-central Alaska. c. Western hemlock-Sitka spruce-(western redcedar) - is a widespread forest type in southeastern Alaska. It also occurs in a narrow coastal band in south-central Alaska. South of 57"N, it usually contains western redcedar. d. Western hemlock-western redcedar - occurs in low producing, poorly drained ecosystems in southeastern Alaska. e. Mountain hemlock - occurs near timberline, normally on saturated soils. This type covers considerable land area both on the mainland and on the major islands of southeastern Alaska. It also occurs as a narrow subalpine band in south-central Alaska. f. Western hemlock-mountain hemlock - in southeastern Alaska, is transitional between the subalpine mountain hemlock zone and the Sitka spruce-western hemlock zone. g. Silver fir - has a limited distribution in southern portions of southeastern Alaska. h. Subalpine fir - occurs in scattered locations near treeline in southeastern Alaska. i. Black spruce - generally occurs on poorly drained organic soils, often underlain by permafrost. It has wide distribu- tion in interior, western, southwestern, northwestern, and south-central Alaska. j. Black spruce-white spruce - occurs in interior Alaska near the northern and western limits of trees. It also occurs on terraces and at the base of south-facing slopes. Tsuga heteroph ylla-Picea sitchensis- (Thuja plica ta)/Vaccinium ovalifolium- V. alaskensis/Rhytidiadelphus loreus (Alaback 1980, Neiland 1971, Stephens et al. 1969) Tsuga heteroph ylla-Picea sitchensis- (Thuja plica ta)/L ysichiton americanum/Sphagnum recurvum (Neiland 1971) Tsuga heteroph ylla- Thuja plicata/Vaccinium o valifolium- Lysichiton americanurn (Alaback 1980, Stephens et al. 1969) Tsuga mertensiana/Vaccinium ovalifolium Cladothamnus pyrolaeflorus (Alaback 1980, Stephens et al. 1969) Tsuga heteroph ylla- T. mertensiana/Vacciniurn ovalifolium- V. alaskensis/Rubus pedatus/Rh ytidiadelphus loreus (Neiland 1971) Abies amabilis-Tsuga heterophylla (Juday et al. 1979) Abies lasiocarpa-Tsuga mertensiana (Harris 1965, Worley and Jaques 1973) Picea marianalfeathermoss (Drury 1956, Lutz 1956, Neiland Picea mariana/Rosa acicularis/Peltigera (Foote 1976, La Roi and Viereck 1977, Viereck 1975) 1967) Picea rnariana-I? glaucalfeathermoss (Foote 1976; LaRoi 1967; Neiland and Viereck 1977; Viereck 1970a, 1975)
k. White spruce - is widespread in south-central and interior Alaska and extends to the limits of tree growth along rivers draining the Brooks Range. It generally occupies sites with well-drained, permafrost-free soils. (2) Open conifer forest a. Shore pine-western hemlock-(western redcedar-Alaska yellow-cedar) (western redcedar south of 57"N) - is limited in southeastern Alaska and generally found on boggy, poorly drained sites that are locally termed muskegs and bogs. b. Sitka spruce - occurs in coastal areas in south-central and southeastern Alaska, often on alluvial deposits and glacial moraines and outwash, and adjacent to coastal wetlands. c. Mountain hemlock - forms a transition between the continuous closed stands of mountain hemlock and the alpine tundra zone in southeastern Alaska. d. Black spruce-white spruce - occurs mostly near treeline in interior, southwestern, western, northwestern, and south-central Alaska. e. White spruce - is similar to the closed white spruce type but with more shrub cover because of the more open tree canopy. Found commonly on well-drained sites and near treeline in interior, southwest, northwest, and south- central Alaska. f. Black spruce - is extremely common on poorly drained, cold sites in interior and south-central Alaska. g. Black spruce-tamarack - is found on wet lowland sites with shallow permafrost. It is restricted to interior Alaska. Picea glaucalfeatherrnoss (Buckley and Libby 1957; Drury Picea glauca/Viburnum edule/Equisetum arvense ( Foote 1976) Picea glauca/Linnaea borealis-Equisetum sylvaticum ( Foote 1956; Viereck 1970a, 1975) 1976) Pinus contorta- Tsuga heteroph ylla-(Thuja plicata-Chamaecyparis n oo tka tensis)/Vaccinium o vali folium V. alaskensis- Ledum groenlandicum/Sphagnum squarrosum (Neiland 197 1) Picea sitchensis/Alnus sinuata/Calamagrostis canadensis (Viereck 1979, Worley 1977) Picea sitchensis/Alnus tenuifolia Tsuga mertensiandCassiope sp p. - Vaccinium ovalifolium- Fauria crista-galli (Alaback 1980, Jaques 1973) Picea mariana-P. glauca/Betula glandulosa (Viereck 1979) Picea glauca/Betula glandulosa/Hylocomium splendens (Hettinger and Janz 1974; Viereck 1970b, 1975, 1979; Williamson and Peyton 1962) Picea glauca/Betula glandulosa/Sphagnum (Hettinger and Janz 1974; Viereck 1970b, 1975, 1979; Williamson an! Peyton 1962) Picea glauca/Betula glandulosa/Cladonia ( Racine and Anderson 1979, Viereck 1979) Picea glauca/Alnus tenuifolia Picea mariana/Vacciniumlfeathermoss (Drury 1956; Foote Picea marianalfeathermoss-Cladonia (Foote 1976; Viereck Picea mariana/Sphagnum-Cladonia (Neiland and Viereck 1977) 1976; Lutz 1956; Viereck 1975, 1979) 1975, 1979) Picea mariana- Larix laricina
A Preliminary Classification for Alaska Vegetation (Continued) 0 Level I Level II Level Ill Level IV Level V 1. Forest A. Conifer (3) Conifer a. Shore pine-(Alaska yellow-cedar) - is found only in Pinus con torta- (Chamaec yparis nootkatensis)/Empetrum (continued) forest wood land southeastern Alaska and is generally on boggy, poorly nigrum- Ledum groenlandicum/Carex pluri flora/Sphagnum (continued) drained sites. fuscum (Neiland 1971) Pinus contorta- (Chamaecyparis nootkatensis)/Vaccinium uliginosum/Trichophorum cespitosum/Sphagnum compactum-S. tenellum- I ichens ( Nei land 197 1 ) Eriophorum angusti folium/Sphagnum lindbergii-S. papillosum (Neiland 1971) Rh ynchospora alba/Sphagnum lindbergii-S. tenellum (Neiland 1971) Pinus con torta/Kalmia poli folia/Eriophorum angustifolium- Carex pluriflora- To fieldia occiden talis- Fauria crista-galli/ Sphagnum lindbergii-S. compactum (Neiland 1971) Pinus contorta/Carex livida-C. ph yllomanica- Rubus arcticus- Platanthera dilitata/Sphagnum papillosum-S. recurvum (Neiland 1971) Pinus contorta- (Chamaecyparis nootkatensis)/Carex livida- Pinus contorta-(Chamaecyparis nootkatensis)/Drosera anglica- b. Black spruce - is found on wet, boggy sites where it Picea mariana/Vaccinium-Salix ( Racine 1976) Picea mariana/Sphagnum-Cladonia (Viereck 1975, 1979) Picea mariana/Cladonia (Foote 1976; Racine 1976; Viereck often grades into a sphagnum bog, and on dry upland sites where lichens are frequently important in the understory. It is common in interior, south-central, southwest, and northwest Alaska. 1975, 1979) c. Black spruce-white spruce - occurs in interior, south- central, southwest, and northwest Alaska, especially near the northern, western, and altitudinal limit of trees. Picea mariana-P. glauca/Betula glandulosa/fea th er m oss Picea glauca-P. marianallichen (Foote 1976) (Viereck 1979) d. White spruce - is a very open, woodland type especially common at the northern limits of tree growth and at elevational tree I ines. Picea glauca/Betula glandulosalfeatherm oss-Cladonia ( H ett i nger and Janz 1974; Racine 1975; Viereck 1975, 1979; William- son and Peyton 1962) Picea glauca/Dryas-moss (Viereck 1979) Picea glauca/Cladonia (Racine 1976) Picea glauca/Salix lanata/Cladonia ( LaPerriere 1979) B. Deciduous (1) Closed a. Red alder - occupies moist sites and disturbed areas in Alnus rubra (del Moral and Watson 1978) forest deciduous southeastern Alaska. forest b. Black cottonwood - is generally found along streams in Populus trichocarpa southeastern and south-central Alaska. c. Balsam poplar ~ occurs most frequently on river flood plains in interior, south-central, and southwestern Alaska, although there are several isolated clumps on the north slope of the Brooks Range. Populus balsamifera/Alnus tenui folia/Calamagrostis canadensis (Buckley and Libby 1957; Drury 1956; Hettinger and Janz 1974; Lutz 1956; Neiland and Viereck 1977; Racine 1976; Viereck 1970a. 1975) (Viereck 1970b) Populus balsamifera/Salix barcla yi/Heracleum lanatum Populus balsamifera/Salix-Alnus/herb (Viereck 1979)
d. Paper birch - occurs on a variety of upland sites, both with and without permafrost, in interior and south-central Alaska. e. Aspen - occurs on warm, well-drained upland soils in interior and south-central Alaska. f. Birch-aspen - is found on moderately warm sites in interior and south-central Alaska and is generally replaced by white spruce. (2) Open deciduous forest a. Paper birch - occurs on dry to moist sites in interior, south-central, and western Alaska. On drier sites, lichens are important in the understory; on moist sites, shrubs are dominant. b. Aspen - occurs primarily on extremely dry sites on steep south slopes in interior and south-central Alaska. c. Balsam poplar - occurs as open clumps near tree line in i n te r i o r , south -ce n t ra I, southwest ern , a n'd north we st ern Alaska and as isolated groves on the north slope of the Brooks Range. (3) Deciduous woodland a. Paper birch - occurs on dry sites, such as old sand dunes and coarse gravel deposits, in northwest Alaska and the northern portion of interior Alaska. C. Mixed (1 1 Closed conifer and mixed deciduous forest forest a. Spruce-birch - tends to occur on cool, wet sites when black spruce is present in the mixture; white spruce favors warmer, drier sites. The type is found primarily in interior and south-central Alaska and, to a lesser extent, in north- west and southwest Alaska. b. Aspen-spruce - is an intermediate successional stage, with spruce as the eventual climax. Aspen generally occurs with white spruce on warm, well-drained sites. The type is most common in interior and south-central Alaska. c. Poplar-spruce-- is an intermediate successional stage lead- ing to white spruce climax on flood plain sites in interior, south-central, southwestern, and northwestern Alaska. Betula papyrifera/Alnus crispa/Calamagrostis (Buckley and Libby 1957; Lutz 1956; Viereck 1975) Betula papyrifera/Viburnum (Foote 1976) Betula papyrifera/Alnus-Salix (Racine 1976) Populus tremuloides/Viburnum edule/Linnaea borealis Populus tremuloides/Salix s p p . fA rctos taph ylos uva-ursi (Foote 1976) (Hettinger and Janz 1974; Viereck 1975) Betula papyri fera-Populus tremuloides Betula papyrifera/Cladonia ( Racine 1976) Betula papyrifera/Betula glandulosa/Hylocomium ( Hanson 1953; Hettinger and Janz 1974; Viereck 1975, 1979) Betula papyrifera/Viburnum edule/Calamagrostis ( Foote 1976) Populus tremuloides/Arctostaph ylos uva-ursi Populus balsamifera/Salix-Alnus/Calamagrostis ( Racine and Anderson 1979; Viereck 1979) Betula papyrifera/Cladonia (Racine 1976) Picea glauca- Betula papyri fera/Alnus crispa/Calamagrostis canadensis (Buckley and Libby 1957; Hettinger and Janz 1974; Lutz 1956; Viereck 1975) Picea mariana- Betula pap yrifera/Ledum Betula papyri fera- Picea glauca-P. mariana/Calamagrostis (Foote 1976) Populus tremuloides-Picea glauca/Arctostaph ylos uva-ursi (Buckley and Libby 1957; Lutz 1956; Viereck 1975) Populus tremuloides-Picea mariana/Ledum (Viereck 1975) Populus tremuloides-Picea mariana/Cornus canadensis (Foote 1976) Populus balsami fera-Picea glauca/Alnus/Equise tum
A 10 Preliminary Classification for Alaska Vegetation (Continued) Level I Level II Level Ill Level IV Level V 1. Forest C. Mixed (2) Open a. Spruce-birch - occurs on a variety of upland sites in (continued) conifer and mixed interior, south-central, southwestern, and northwestern deciduous forest Alaska. forest (continued) 2. Tundra A. Sedge-grass (1 ) Wet a. Wet sedge meadow - is found in very wet areas, generally underlain by permafrost, in every part of the State except southeast but is especially characteristic of the arctic coastal plain. tundra sedge-grass b. Wet sedge-grass meadow - is largely confined to the arctic coastal plain in very wet areas underlain by shallow perrnaf rost. Picea glauca- Betula papyri fera/Calamagrostis- Hylocomium Picea glauca- Betula papyri fera/Alnus crispa/Sphagnum Picea glauca- Betula papyri fera/Salix plani folia/Sphagnum Picea mariana- Betula papyri fera/Cladonia (Hettinger and Janz 1974; Viereck 1975) (Viereck 1975) (Viereck 1970b) Carex aquatilis (Churchill 1955; Clebsch 1957; Fries 1977; George et al. 1977; Komarkova and Webber 1978, 1980; Scott 1974; Spetzman 1959; Webber 1978; Webber et al. 1978; White et al. 1975; Young 1971) Carex aquatilis-Eriophorum angustifolium (Batten 1977; Childs 1969; Hopkins and Sigafoos 1951; Johnson et al. 1966; Kessel and Schaller 1960; Pegau 1968; Racine 1977; Racine and Young 1978; Webber and Walker 1975; Webber et al. 1978; Young 1974; Young and Racine 1978) Carex aquatilis-C. rotundata (George et al. 1977; Hanson 1953; Pegau and Hemming 1972) Carex aquatilis- C. chordorrhiza- C. limosa- C. microglochin- Eriophorum scheuchzeri-E. angustifolium (Drew and Shanks 1965) Eriophorum angustifolium (White et al. 1975) Eriophorum angustifolium-Carex chordorrhiza (Webber et al. Eriophorum angustifolium-Carex aquatilis-C. lachenalii ( Klein Eriophorum angustifolium-Carex bigelowii (Anderson 1974; Carex bigelowii-C. rariflora-C. saxatilis (Hettinger and Janz Carex chordorrhiza (Batten 1977; Spetzrnan 1959) Carex rariflora (Batten 1977; Hanson 1951 ; Spetzrnan 1959) 1978) 1958; Rausch and Rausch 1968) Hanson 1950; Koranda 1960; Viereck 1963) 1974) Carex aquatilis-Dupontia fischeri (Potter 1972; Webber and Walker 1975; Webber et al. 1978; White et al. 1975; Wiggins 1951) Webber 1978) Dupontia fischeri- Eriophorum angustifolium (Dennis 1969; Dupontia fischeri-Eriophorum scheuchzeri (Spetzrnan 1959) Dupontia fischeri-Carex aquatilis- Eriophorum scheuchzeri- E. angustifolium (Clebsch 1957; Dennis 1969; Potter 1972; Wiggins 1951) caespitosa- Dupontia fischeri-Arctagrostis la ti folia (Johnson et al. 1966) Erioph orum angus ti folium - Carex glareosa- Deschampsia
(2) Mesic . sedge-grass (3) Sedge-shrub c. Wet sedge-herb meadow - is usually of minor extent, such as on streamsides and pond margins. a. Mesic sedge-grass meadow - is usually of minor extent. b. Mesic sedge-herb meadow - is usually of minor extent; probably most common in south-central and southeastern Alaska c. Arctic grass-herb meadow - occurs in small, limited areas, mainly reported from the arctic slope but probably more widespread. a. Sedge-willow - is widely distributed in tundra areas throughout Alaska, except the south-central and south- eastern parts; probably most abundant from the Brooks Range northward. b. Sedge-birch - occurs in northern and western interior Alaska. (4) Sedge-mat a. Sedge-dryas - is widely distributed in tundra areas and cushion throughout the State, with the exception of south-central and southeastern Alaska. b. Sedge-bearberry - is only reported from the Seward Peninsula and northeastern interior Alaska but is probably present in other areas, such as the Alaska Range. Carex aquatitis-Potentilla palustris (Bliss and Cantlon 1957; Carex aquatilis-Menyanthes trifoliata I Webber et al. 1978) Carex aqua titis- C. membranacea- Petasites frigidus (Scott 1 974 ) Carex nigricans- Eriophorum angusti folium- Fauria crista-galli- Webber et al. 1978) Trichophorum caespitosum (Jaques 1973) Carex aquatilis-Poa arctica (Clebsch 1957; Webber 1978) Carex microchaeta-Poa arctica (Batten 1977) Carex podocarpa-A rctagrostis la tifolia (Scott 1 974 1 Carex macrochaeta- Geranium erianthum- Erigeron peregrinus- Lupinus nootkatensis (Hjeljord 1971 1 Epilobium la ti folium - Mertensia panicula ta- A rctagros tis la ti folia Bromus pumpellianus- Trisetum spicatum- Bupleurum Luzula confusa-Poa arctica-Petasites frigidus (Wiggins 1951 1 (Anderson 1974) triradiatum (Koranda 1960) Carex aquatilis-Salix planifolia (Childs 1969; Clebsch 1957; Dennis 1969; Hanson 1951; Hettinger and Janz 1974; Webber et al. 1978) Carex aquatitis-Salix lanata (Scott 1974; Spetzman 1959) Carex aquatilis-Alnus crispa-Salix spp. (Bliss and Cantlon 1957) Carex bigelowii-Salix planifolia (Hettinger and Janz 1974; Carex bigelowii-Salix reticulata-S. planifolia (Batten 1977; Carex bigelowii-Salix reticulata (Hettinger and Janz 1974) Eriophorum angustifolium-Salix planifolia (Fries 1977) Carex bigelo wii- C. membranacea-Salix polaris- Equise tum Carex nesophila-Salix rotundifolia-S. reticulata (Klein 1958) Carex microchaeta-Salix planifolia-S. reticulata (Batten 19771 Johnson et al. 1966; Koranda 1960) Hettinger and Janz 1974) arvense (Hanson 1950) Carex bigelowii-Betula nana (Webber et al. 1978) Carex bigelowii-C. aquatitis-Betula nana (Hettinger and Janz 1974) Carex aquatilis-Dryas integrifolia (Webber and Walker 1975; Carex bigelo wii- Dryas in tegrifolia ( C h i Ids 1 969; H e tt i nger and Carex bigelowii-Dryas octopetala-Salix reticulata (Anderson Kobresia sirnpliciuscula-Dryas integrifolia (Webber et al. 19781 Carex membranacea-Arctostaphylos rubra (Hettinger and Janz Carex bigelo wii-Arctostaph ylos alpina- L oiseleuria procumbens- Webber et al. 1978) Janz 1974; Webber et al. 1978) 1974; Scott 1974; Webber et al. 1978) 1974) Diapensia lapponica (Racine and Anderson 1979) 1
Preliminary Classification for Alaska Vegetation (Continued) ~~~ ~ Level I Level II Level Ill Level IV Level V 2. Tundra B. Herbaceous (1 ) Low elevation a. Seral herbs - are especially common north of the Brooks tundra most of the State. Epilobium latifolium (Scott 1974; Webber et al. 1978) Cantlon 1957; Johnson et al. 1966; Spetzman 1959) Epilobium latifolium-Crepis nana (Young 1974) Hedysarum alpinum-Artemisia arctica (Webber et al. 1978) Cochlearia o fficinalis- Ox yria digyna-Saxifraga rivularis Cochlearia o fficinalis-Phippsia algida-Stellaria humifusa Wilhelmsia ph ysodes-Artemisia arctica- Chrysan themum Equisetum variegatum (Young 1974) (continued) tundra herbaceous Range but are encountered in small areas throughout Epilobium latifolium-Artemisia tilesii (Batten 1977; Bliss and (Potter 1972) (Webber 1978) arcticum (Thomas 1951 ) (2) Alpine herbaceous tundra a. Herb-sedge (snowbed) - includes a wide variety of types Cetraria delisei-Ox yria digyna- Koenigia islandica-Saxi fraga Carex lachenalii-Oxyria digyna-Claytonia sarmentosa (Scott 1974) Rhacomitrium canescens- Dicrano weisia cirra ta- Ox yria dig yna (Scott 1974) An thelia julacea-Scapania paludosa-Saxi fraga hirculus- Leptarrhena pyrolifolia (Shacklette et al. 1969) Rubus arcticus-Sedum rosea-Polygonum bistorta-Saxifraga hirculus (Racine and Young 1978) Carex nigricans (Jaques 1973) in mountainous areas throughout the State. rivularis (Johnson et al. 1966) b. Alpine herbs - occur primarily as sparse vegetation on talus and blockfields, and in some well-vegetated herbaceous meadows in alpine valleys. Saxifraga tricuspidata-Draba caesia (Batten 1977; Johnson Saxifraga oppositifolia (Griggs 1936) Saxifraga oppositifolia-Epilobium latifolium (Viereck 1963) Saxifraga tricuspidata-Artemisia arctica (Webber et al. 1978) Potentilla h yparctica-Cerastium aleuticuni- Draba aleutica (Shacklette et al. 1969) Artemisia arctica-Potentilla h yparctica- Hierochloe alpina (Heusser 1954, 1960) Diapensia lapponica-Saxifraga bronchialis-Sibbaldia procumbens- Trisetum spicatum (Griggs 1936) Saxifraga spp.-Festuca brachyphylla-Poa glauca-Luzula confusa-Minuartia spp. (Spetzman 1959) Ox yria digyna-Saxi fraga puncta ta-Sedum rosea- Priniula tschuktschoruni (Fries 1977) L ue tkea pectina ta- Cassiope s telleriana- Cladon ia s p p. - Lycopodium alpinum (Hanson 1951) Fauria crista-galli-Caltha biflora (Klein 1965) Achillea borealis-Arnica utialaschcensis-Cla ytonia sibirica- Geum calthifoliuni (Shacklette et al. 1969) Polygonum viviparum-Campanula lasiocarpa-Primula cuneifolia- Cardamine umbellata (Bank 1951) et al. 1966)
C. Tussock (1 Sedge tussock a. Eriophorum tussock - nearly pure eriophorum tussock tundra vegetation with no important associated species is relatively rare but has been reported from a few localities on the arctic slope Eriophorum vaginatum (Johnson et al. 1966, Komarkova and Webber 1978) (2) Sedge a. Sedge tussock-willow - is mostly restricted to north of Eriophorum vaginatum-Salix planifolia-Carex bigelo wii/ Hylocomium splendens (Hettinger and Janz 1974) Eriophorum vaginatum-Salix planifolia-S. lanata ( Koranda 1960) tussock-shrub the Brooks Range on poorly drained level to gently sloping surfaces. b. Sedge tussock-ericaceous shrub - is scattered in northern Eriophorum vaginatum-Carex bigelo wii- Ledum palustre- and western interior Alaska. Vaccinium vitis-idaea (Childs 1969; Dean and Chesemore 1974; Hanson 1950) c. Sedge tussock-mixed shrub - is widely distributed throughout the Seward Peninsula and interior and northern Alaska. D. Shrub (1) Willow a. Willow-sedge - is largely concentrated north of the tundra Brooks Range, where it occurs in the foothills and the arctic coastal plain b. Willow-grass - may not be a very widespread type; it has only been described from the arctic coastal plain. Eriophorum vaginatum- Betula nana- Ledum palustre- Vaccinium spp. (Clebsch 1957; Drew and Shanks 1965; Hanson 1953; Pegau 1968; Ugolini and Walters 1974; Young and Racine 1978) Eriophorum vaginatum-Betula nana-Salix planifolia- Ledum palustre- Vaccinium spp. (Johnson et al. 1966; Koranda 1960; Young 1974) Eriophorum vaginatum-Betula nana-Salix lanata- Ledum palustre- Vaccinium spp. (Webber et al. 1978) Eriophorum vaginatum-Betula nana- Ledum palustre- Vaccinium spp.-Carex bigelowii (Churchill 1955; Hopkins and Sigafoos 1951; Racine 1977; Viereck 1966; Young and Racine 1977) palustre- Vaccinium spp.-Carex bigelowii (Spetzman 1959; Webber et al. 1978) Eriophorum vaginatum-Betula nana (Batten 1977; Kessel and Schaller 1960; Komarkova and Webber 1980; Webber et al. 1978) Carex bigelowii- Betula nana-Salix plani folia- Ledum palustre- Vaccinium spp. (Racine and Anderson 1979; Racine and Young 1978) Eriophorum vaginatum-Betula nana-Salix planifolia- Ledum Salix planifolia-Carex aquatilis ( Komarkovd and Webber 1978, Salix lanata-Carex aquatilis (Webber and Walker 1975; Webber Salix lanata-Carex vaginata/Hylocomium splendens (Hettinger 1980) et al. 1978) and Janz 1974) Salix planifolia/S. rotundifolia-S. phleboph ylla-Petasites frigidus-Poa arctica-Luzula confusa (Clebsch 1957)
L Preliminary Classification for Alaska Vegetation (Continued) m Level I Level II Level Ill Level IV Level V 2. Tundra D. Shrub (2) Birch and a. (continued) tundra ericaceous (continued) shrubs b. Birch and ericaceous shrubs-sedge - is common in interior and northern Alaska. Betula nana- Ledum palustre- Vaccinium spp.-Carex bigelo wii (Bliss and Cantlon 1957; Churchill 1955; Hanson 1950, 1951) Eriophorum vaginatum- Carex bigelo wii-Arctagrostis la tifolia (Churchill 1955) Betula nana- Ledum palustre- Vaccinium spp.-Empetrum nigrum- Birch and ericaceous shrubs-grass - may not be a very widespread type. Betula nana- Ledum palustre- Vaccinium vitis-idaea- Empetrum nigrum-Arctagrostis latifolia-Hierochloe alpina (Churchill 1955) Betula nana- Ledum palustre- Vaccinium vitis-idaea-Arctagrostis latifolia (Churchill 1955) c. Birch and ericaceous shrubs-sphagnum - is widespread throughout northern and western Alaska. Betula nana- Ledum palustre- Vaccinium spp.- Rubus chamaemorus/Sphagnum spp. (Drew and Shanks 1965; Fries 1977; Hanson 1953; Pegau and Hemming 1972; Webber et al. 1978; Young and Racine 1977) nigrum-Sphagnum spp.-Hylocomium sp. (Young and Racine 1978; Palmer and Rouse 1945) Betula nana- Ledum palustre- Vaccinium vitis-idaea- Empetrum d. Crowberry - is characteristic of southern Alaska and the Empetrum nigrum-Cassiope stelleriana-Ph yllodoce aleutica- Vaccinium spp. (Cooper 1942; Heusser 1960) Empetrum nigrum- Vaccinium spp.-Ledum palustre-Betula nana (Griggs 1936; Racine and Young 1978) Empetrum nigrum- L ycopodium spp.lBrach ythecium albicans- Cladonia spp. (Bank 1951) Empetrum nigrum- Carex pluri flora-C. macrochaeta/Cladonia spp. (Bank 1951; Everett 1971; Hulten 1960; Shacklette et al. 1969) Ernpetrum nigrum-Cassiope lycopodioides- Carex circinna ta/ mosses (Byrd and Woolington 1977) Empetrum nigrum-Arctostaphylos alpina (Fries 1977) Empetrum nigrum-Vaccinium uliginosum (Hulten 1962) Aleutian Islands. e. Ericaceous shrubs - are abundant in most areas of the State except north of the Brooks Range. Ledum palustre- Vaccinium spp.-Arctostaph ylos alpina-Cassiope tetragona (Johnson et al. 1966; Pegau and Hemming 1972) Vaccinium spp.- Ledum palustre- Empetrum nigrum- Arctostaphylos alpinallichens (Hettinger and Janz 1974) Vaccinium vitis-idaea- Empetrum nigrum/Cladina spp. ( Racine and Anderson 1979) Vaccinium uliginosum- Diapensia lapponica- Ph yllodoce coerulea-Salix Polaris-S. arctica (Fries 1977) Phyllodoce aleutica- Vaccinium spp.-Cassiope stelleriana- Empetrum nigrum (lsleib and Kessel 1973; Palmer 1942) Phyllodoce aleutica-Cassiope stelleriana ( Heusser 1960) Phyllodoce aleutica-Cassiope spp.- Vaccinium spp. (Klein 1965, Cassiope mertensiana-C. stelleriana-Empetrum nigrum ( Heusser Phyllodoce aleutica-Cassiope mertensiana (Jaques 1973) Ward 1957) 1954, 1960)
E. Mat and cushion tundra (3) Mixed shrub f. Undifferentiated understory - is a common type found Betula nana-Ledum palustre- Vaccinium spp. (Batten 1977; in all areas of the State. Koranda 1960; Ugolini and Walters 1974; Webber et al. 1978; Williamson and Peyton 1962) Betula nana- Vaccinium spp.-Empetrum nigrum (Hulten 1966) Betula nana- Ledum palustre- Empetrum nigrum/Cladonia spp.- Stereocaulon spp. (Young and Racine 1978) a. Mixed shrub-grass - may be a relatively rare type. Salix glauca-Arctostaph ylos rubra- Vaccinium uliginosum- Arctagrostis latifolia (Hettinger and Janz 1974) b. Undiffere.ntiated understory - is apparently a common Betula nana- Ledum palustre- Vaccinium spp.-Salix planifolia (Hanson 1953; Johnson et al. 1966; Koranda 1960) Betula nana- Ledum palustre- Vaccinium spp.-Salix planifolia/ Cladonia spp.-Cetraria spp. (Hanson 1953; Pegau 1968) Betula nana-Arctostaph ylos alpina-Salix arctica- Dryas integrifolia (Drew and Shanks 1965) Betula nana- Vaccinium uliginosum-Salix reticulata-Dryas integrifolia-Cassiope tetragona (Hettinger and Janz 1974) Salix glauca-Dryas octopetala-Betula nana (Hettinger and Janz 1974) type found in all tundra areas of the State. (1 ) Open mat a. Snowbed - occurs in alpine draws and on lee slopes and cushion where snow accumulates. b. Dryas-lichen - is widespread in northern and western Alaska. L uetkea pectinata- Ph yllodoce aleutica- Cassiope s p p. ( R ac i ne Salix rotundifolia (Klein 1958; Komarkova and Webber 1978; Salix rotundifolia-Oxyria digyna (Anderson 1974) and Young 1978; Streveler et al. 1973) White et al. 1975) Dryas octopetala-lichens (Anderson 1974; Childs 1969; George et al. 1977; Hanson 1951 ; Spetzman 1959) Dryas integrifolia-lichens (Drew and Shanks 1965; Hanson 1951; Komarkova and Webber 1978; Webber and Walker 1975) Dryas octopetala- I ic hens-Ox ytropis nigrescens-Salix phlebophylla-Carex rnicrochaeta (Johnson et al. 1966) Dryas octopetala-Stereocaulon tornentosum (Scott 1974) Dryas octopetala-Cetraria cuculla ta-o t h er I i c hens- Rhacomitrium Dr yas oc tope tala - Empetrurn n igrum-Salix arc tica- Ce traria s p p . - lanuginosum (Scott 1974) Cladonia spp. (Young and Racine 1978) c. Dryas-herb - is common on dry exposed sites throughout Dryas octopetala- Minuartia spp. -Saxifraga spp. ( Hett i nger and Dryas octopetala- Astragalus s p p . - Hedysarum alpinum ( Ha nso n Dryas integrifolia-Oxytropis nigrescens- Carex rupestris Dryas integrifolia- Lupinus arcticus ( C hu rc h i I I 1 955 1 Dryas integrifolia-Hedysarum atpinurn- Festuca rubra ( Hanson Dr yas drumrnondii- D. in tegri folia- As tragalus s p p . - Ox y tropis the State. Janz 1974; Nodler et ai. 1978) 1953; Johnson et al. 1966) ( Koranda 1960; Webber and Walker 1975) 1951) carnpestris-Hedysarum mackenzii (Viereck 1966)
Preliminary Classification for Alaska Vegetation (Continued) Level I Level II Level Ill Level IV Level V 2. Tundra E. Mat and (1 ) Open mat d. Dryas-sedge - is common on dry exposed sites through- (continued) cushion and cushion out the State. tundra (continued1 (continued) e. Willow - generally occurs on stony soils, from south- central Alaska north and west. f. Ericaceous shrubs - occur in shallow, stony soils in the mountains or at low elevations. g. Open lichen - occurs on extremely harsh, windblown rocky sites with little or no soil development. (2) Closed mat a. Prostrate shrubs and herbs on flood plains - occur along and cushion rivers in interior Alaska, northward and westward. b. Mat and cushion-sedge - is found in all sections of Alaska except southeastern. Dryas octopetala-Carex microchaeta (Webber et al. 1978) Dryas octopetala-Carex misandra-C. bigelowii (Hanson 1951 ) Dryas octopetala-Carex glacialis (Gjaerevoll 1954) Dryas octopetala-Carex nardina-C. vaginata-lichen (George Dryas integri folia-Carex scirpoidea- Kobresia simpliciuscula et al. 1977) (Koranda 1960) Salix rotundifolia (Webber 1978) Salix ovalifolia (Webber et at. 1978; White et al. 1975) Salix reticula ta- Carex microchaeta- Rhacomitrium lanuginosum Salix reticulata-Carex saxatilis (Hettinger and Janz 1974) Salix rotundifolia-Potentilla vahliana-Saxi fraga oppositifolia Salix polaris-Cetraria islandica-Cladina rangiferina (Scott 1974) Salix arctica-Carex nesophila- Cladina alpestris- Cetraria cucullata Salix arctica-S. rotundifolia- Empetrum nigrum (Shacklette Salix rotundi folia-S. o vali folia-Cassiope lycopodioides- (Hettinger and Janz 1974) (Racine and Anderson 1979) (Klein 1958) et al. 1969) Empetrum nigrum (Shacklette et al. 1969) Vaccinium vitis-idaea-Salix phleboph ylla-arc tostaph ylos L edum palus tre-Salix reticula ta- Dryas octope tala- Empetrum L oiseleuria procumbens- Vaccinium uliginosum-Salix arctica- alpina (Anderson 1974) nigrum-Poa alpina (Hettinger and Janz 1974) Ledum palustre (Griggs 1936) Umbilicaria spp.-Rhizocarpon spp. (Anderson 1974; Hanson 1953; Kessel and Schaller 1960; Klein 1958; Pegau 1968; Rausch and Rausch 1968; Webber et al. 1978) 1966) Cladina spp.-Cetraria spp.-Stereocaulon sp. (Johnson et al. Dryas integrifolia-Poa glauca-Oxytropis borealis ( Koranda Dryas octopetala-Anemone drummondii- Lesquerella arctica- 1960) Crepis nana (Drew and Shanks 1965) Dryas octopetala-Carex scirpoidea (Gjaerevoll 1954) Dryas octopetala-Kobresia myosuroides (Drew and Shanks Dryas octopetala-Kobresia simpliciuscula (Gjaerevoll 1954) Dryas octopetala- Vaccinium vitis-idaea- Luzula spp.-Carex Dryas octopetala-Carex franklinii (Gjaerevoll 1954) Dryas octopetala-Salix arctica- Carex bigelo wii- m osses 1965; Johnson et al. 1966; Spetzman 1959) misandra (Childs 1969) (Anderson 1974)
Dryas octopetala-Salix reticulata-Carex bigelowii (Hanson 1950, 1953; Viereck 1963) Salix reticula ta- Dr yas oc tope tala- Carex podocarpa (Scott 1974) Vaccinium uligin osum- Dr yas oc tope tala- Carex bigelo wii (Anderson 1974) Dryas integrifolia-Salix reticulata-Carex scirpoidea (Batten 1977; Drew and Shanks 1965; Hettinger and Janz 1974) Dryas integrifolia-Salix reticulata-Carex bigelowii ( Hettinger and Janz 1974) Dryas integrifolia-Carex misandra- Rh ytidium rugosum (Hettinger and Janz 1974) Dryas integrifolia- Vaccinium spp.-Carex spp. (Drew and Shanks 1965) Salix polaris-S. reticulata- Hylocomium splendens-Carex podocarpa (Scott 1974) c. Mat and cushion-grass - may not be a very abundant type. Vaccinium vitis-idaea-Dryas octopetala- Empetrum nigrum- Salix ovalifolia- Empetrum nigrum- Festuca rubra-Calamagrostis Festuca altaica (Scott 1974) deschampsioides (Hanson 195 1 1 d. Dryas - is a very widespread type throughout Alaska ' Dryas octopetala (Viereck 1963) except south-central and southeastern. Dryas octopetala-Salix reticula ta- Cassiope tetragona (Anderson 1974; Batten 1977; Kessel and Schaller 1960; Viereck 1962a, 1963) Dryas octopetala- Vaccinium uliginosum-Salix reticulata (Anderson 1974) Dryas octopetala-Arctostaphylos alpina (Webber et ai. 1978; Young 1974) Dryas octopetala-Arctostaph ylos alpina- Tomenth ypnum nitens-Carex bigelowii (Webber et al. 1978) Dryas octopetala- Diapensia lapponica- L oiseleuria procumbens- Vaccinium vitis-idaea-lichens (Racine and Young 1978) Dryas octopetala-Cetraria spp.-Cladonia spp. (Pegau 1968; Viereck 1962a) Dryas integrifolia (Komarkovd and Webber 1978, 1980; Webber and Walker 1975) Dryas integrifolia-Cassiope tetragona ( Komarkova and Webber 1978, 1980; Koranda 1960) Dryas integrifolia-Arctostaphylos rubra ( Koranda 1960; Webber et al. 1978) e. Cassiope - is a widespread type, usually in relatively Cassiope tetragona (Anderson 1974; Komarkova and Webber 1978, 1980; Pegau 1968; Scott 1974; Webber et al. 1978) Cassiope tetragona-Salix rotundifolia-mosses (Batten 1977, Webber and Walker 1975) Cassiope tetragona- Vaccinium uliginosum-mosses ( Hanson 1953; Scott 1974) Cassiope tetragona- Vaccinium vitis-idaea (Childs 1969; Webber et al. 1978) mesic or shaded settings, in interior, western, and northern Alaska.
N 0 Preliminary Classification for Alaska Vegetation (Continued) Level I Level II Level Ill Level IV Level V 2. Tundra E. Matand (2) Closed mat f. Bearberry - is common on the Seward Peninsula. (continued) cushion and cushion tundra (continued) (continued) 3. Shrub- A. Tall land shrub (1) Closed tall shrub a. Willow - (sometimes called willow thickets) is especially characteristic of flood plains and common in interior, western, and northern Alaska. b. Alder - closed Alnus sinuata communities are common in south-central and southeastern Alaska. In southwestern, northwestern, and interior Alaska, closed stands of Alnus crispa are common. c. Shrub birch - is generally found in openings in taiga in interior Alaska near tree line. d. Alder-willow - occurs on flood plain terraces and drainageways on slopes. e. Shrub birch-willow - is apparently no1 a very common type but present on the Seward Peninsula. Arctostaphylos alpina- Vaccinium vitis-idaea (Hanson 1953) Arctostaphylos alpina- Rhododendron camtschaticum Arctostaphylos rubra-Cladonia (Webber et al. 1978) (Pegau 1968) Salix alaxensis (Bliss and Cantlon 1957; Griggs 1936; Hanson 1953; Johnson et al. 1966; Pegau and Hemming 1972; Spetzman 1959; Viereck 1963) Komarkova and Webber 1980; Spetzman 1959; Wiggins and Thomas 1962; Young 1974) Salix alaxensis-S. planifolia (Johnson et al. 1966; Young and Racine 1977) Salix alaxensis-S. arbusculoides-S. glauca/Equisetum arvense- Pyrola grandiflora (Batten 1977; Bliss and Cantlon 1957) Salix alaxensis-S. arbusculoides/Calamagrostis canadensis- Equisetum pratense (Hulten 1966) Salix planifolia (Hopkins and Sigafoos 1951; Hulten 1962; Johnson et al. 1966) Salix glauca-S, planifolia-S. lanata (Batten 1977; Childs 1969; Griggs 1936; Hanson 1953; Koranda 1960; Pegau 1968; Racine and Anderson 1979; Racine 1977; Viereck 1962a) Salix alaxensis-S. glauca-S. lanata (Drew and Shanks 1965; Salix barclayi (del Moral and Watson 1978; Hulten 1960) Alnus crispa/Calamagrostis canadensis (Young and Racine 1977) Alnus crispa/Calamagrostis canadensis ( Hanson 1953; Viereck Alms crispa-Salix arbusculoides-S. glauca/Delphinium 1962a) glaucum-Aconitum delphinifolium-Calamagrostis spp. (Viereck 1963) 1978) Alnus sinuata (Cooper 1942; Palmer 1942; Young and Racine Alnus sinuata/Calamagrostis canadensis (Hulten 1960, 1962) Alnus sinuata/Rubus spectabilis (Heusser 1960; lsleib and Alnus tenuifolia/Calamagrostis canadensis (Hanson 1953) Kessel 1973; Streveler and Paige 1971 ) Betula glandulosa (Hanson 1953) Alnus crispa-Salix planifolia/Carex bigelowii (George et al A lnus crispa-Salix glauca/A rc tagros tis la ti folia- P yrola Alnus crispa-Salix lanata-S. planifolia-S. glauca (B I iss and 1977; Racine and Anderson 1979) grandiflora (Churchill 1955) Cantlon 1957) Betula glandulosa-Salix planifolia-S. lanata-Atnus crispa (Hanson 1953)
(2) Open a. Willow - occupies a variety of sites, from dunes to river banks; most common in interior, western, and northern Alaska. tall shrub b. Alder - is not nearly as abundant as closed alder com- munities but can be found throughout the State. c. Shrub birch - occurs at and above tree line, especially in the Alaska Range. d. Alder-willow - occurs on flood plain terraces and steep slopes near tree line in interior and northern Alaska. e. Shrub birch-willow - occurs in the tree line zone, especially in the Alaska Range and western Alaska; this type has not yet been described. B. Low (1 1 Closed a. Dwarf birch - thickets are not common but do occur on shrub low shrub the Seward Peninsula and in interior Alaska. b. Low willow - is common in interior, western, and northern Alaska. c. Dwarf birch-willow - has not yet been described. (2) Open a. Dwarf birch - is common in the Alaska Range and on low shrub the Seward Peninsula. Salix alaxensis-S. glauca (Komarkova and Webber 1980) Salix alaxensis/Arctostaphylos rubra (Webber et al. 1978) Salix alaxensis/Astragalus alpinus- Epilobiurn latifoliurn (Webber et al. 1978) Salix alaxensis/Shepherdia canadensis/Dryas octopetala- Arctostaphylos rubra-Cladonia pyxidata (Scott 1974) Salix brach ycarpa-S. barcla yi-S. glauca/Hylocorniurn splendens (Viereck 1966) Salix plani folia-S. glauca/Calarnagrostis canadensis- Epilobiurn angustifoliurn-Equisetum pratense (Young and Racine 1978) Alnus crispa/Calamagrostis canadensis (Young and Racine 1977) Betula glandulosa/Ledurn palustre- Vacciniurn spp.- Arctostaphylos alpina-Festuca altaica (Batten et al. 1979) A lnus crispa-Salix lana ta -S. plan i folia/L edurn palus tre- Carex bigelowii/Sphagnurn spp. (Viereck 1963) Betula nana (Hopkins and Sigafoos 1951; Racine and Anderson Betula glandulosa/Pleuroziurn schreberi- Hylocorniurn splendens 1979) (Viereck 1966) Salix planifolia/Equiseturn arvense (Webber et al. 1978) Salix glauca-S. planifolia-S. lanata (Pegau 1968; Racine 1977) Betula glandulosa/Hylocorniurn splendens (Hettinger and Janz 1974; Viereck 1966) Betula glandulosa/Vacciniurn uliginosurn-Carex bigelo wii/ Aulacornniurn palustre- Hylocorniurn splendens (Scott 1 9 74 1 Betula glandulosa/Vacciniurn uliginosurn- Ledurn palustre/ Cladonia-Cetraria (Kessel and Schaller 1960; Pegau 1968) Betula glandulosa/Vacciniurn uliginosurn- Festuca altaica/Dryas in tegri folia-Salix reticula ta- Ce traria cuculla ta- Cladonia s p p . (Viereck 1962b3 (Anderson 1974) Betula glandulosa/Ledurn palustre- Vacciniurn vitis-idaea b. Low willow - is common in interior, northern, and western Alaska.
tu Preliminary Classification for Alaska Vegetation (Continued) I\) Level I Level II Level Ill Level IV Level V 3. Shrub- B. Low (2) Open b. Low willow - is common in interior, northern, and Salix plani folia/Carex bigelo wii-Pe tasites frigidus/Hylocomium land shrub low shrub western Alaska. splendens (Hettinger and Janz 1974) (continued) (continued) (continued] Salix plani folia/Carex podocarpa- Petasites frigidus ( And e rso n 1974) 1955) Salix planifolia/Carex bigelowii-Arctagrostis latifolia (Churchill Salix glauca/Petasites frigidus (Churchill 1955) Salix glauca/Dryas octopetala (Webber et al. 1978) Salix glauca/S. re ticdata-Carex podocarpa-Artemisia arctica Salix glauca/Arctostaph ylos rubra- Dryas octopetala-Salix Salix glauca/Arctostaphylos alpina (Webber et at. 1978) Salix lanata-S. glauca/Dryas integrifolia ( Komarkova and Salix lanata/Equisetum arvense (Webber et al. 1978) (Scott 1974) reticulata-Oxytropis deflexa (Scott 1974) Webber 1980) c. Dwarf birch-willow - is present in interior and northern Alaska. Betula nana-Salix brach ycarpa-S. planifolia-S. lanata/ Arctostaphylos rubra-Cassiope tetragona- Ledum palustre (Spetzman 1959) Salix arbusculoides-S. glauca-S. hastata- Betula glandulosa/ Bromus pumpellianus-Festuca altaica (Batten 1977) Betula glandulosa-Salix glauca-S. planifolia/Festuca altaica- Vaccinium vitis-idaea-Arctostaph ylos alpina/Hylocomium splendens (Viereck 1963) Salix glauca-Betula nana (Childs 1969) d. Low alder - Alnus crispa forms low thickets at the north edge of its range in the Brooks Range and arctic foothills. Alnus crispa/Vaccinium uliginosum Ledum palustre- Betula nana- Carex bigelo wii/H ylocornium splendens- Aulacornnium palustre (Bliss and Cantlon 1957) e. Low alder-willow - is an uncommon type found on flood Alnus crispa-Salix s pp./Carex bigelo wii- Empetrum nigrum- Vaccinium vitis-idaea/Ce traria cuculla ta- Cladonia s p p. (Bliss and Cantlon 1957) plains in northern Alaska, at the northern edge of the range of alder. f. Shepherdia-dryas - occurs on flood plains in interior Shepherdia canadensis/Dryas octopetala (Scott 1974) Alaska. g. Dwarf birch-sphagnum - has not yet been described in Alaska. h. Mixed shrub-sphagnum - is common in interior and Betula nana- Ledum palustre- Vaccinium vitis-idaea-Carex spp.- Rubus chamaemorus/Sphagnurn spp. (Hanson 1953) Empetrum nigrum- Vaccinium spp.-Carex pluriflora- Rubus chamaemorus/Sphagnum spp. (Hulten 1960) Myrica gale- Betula glandulosa/Carex kelloggii- Rubus chamaemorus/Sphagnum spp. (Griggs 1936) western Alaska.
4. Herba- A. Tall grass (1 ) Bluejoint a. Bluejoint meadow - is found throughout the State except for southeastern and northern Alaska; occupies large areas in south-central and southwestern Alaska. ceous vegetation (2) Bluejoint- herb a. Bluejoint-fireweed - is widely distributed in the southern half of the State. It thrives in disturbed areas. b. Bluejointmixed herbs - are moist to wet meadow types located in southwestern, south-central, and southeastern Alaska. (3) Bluejoint- shrub (4) Herbs a. Bluejoint-alder - is extensive in southwestern Alaska but virtually unknown throughout the rest of the State. a. Mixed herbs - occur on mesic slopes and streambanks from south-central Alaska to the Aleutian Islands. b. Fireweed - occurs on disturbed areas in south-central and southeastern Alaska. c. Cow parsnip - occurs on moist to wet areas, often along drainages, in southeastern and south-central Alaska and the Aleutian Islands. d. Ferns - are restricted to localized areas in southeastern and south-central Alaska and in the Aleutian Islands. (5) Elymus a. Coastal elymus - grows on beaches out of reach of normal tides along the entire Alaska coastline. Calamagrostis canadensis (Bank 1951; Fries 1977; Hanson 1953; Calamagrostis nutkaensis/Festuca rubra ( A m u n dsen and Heusser 1960; Hulten 1966; Pegau and Hemming 1972) Clebsch 1971; Byrd and Woolington 1977) Calamagrostis canadensis-Epilobium angustifolium ( Ha nson 1951; Klein 1958; Young and Racine 1978) Calamagrostis canadensis- Epilobium angusti folium- Geranium erianthum (Heusser 1960) Calamagrostis canadensis- Thalictrum minus- Geranium erianthum-Epilobium angustifolium (Hulten 1960) Calamagrostis canadensis- Epilobium angusti folium- Heracleum lanatum-Angelica genuflexa (Griggs 1936) Calamagrostis canadensis- Deschampsia beringensis- Heracleum lanatum-Angelica lucida (Bank 1951 Calamagrostis canadensis-Alnus sinuata (G riggs 1936) Aconitum delphinifoliurn-Aquilegia formosa-Sanguisorba Streptopus amplexi folius- Linnaea borealis-Juncus arcticus Platan thera s p p .- Fritillaria camscha tcensis- Polygonum A th yrium filix- femina-Carex lyngb yaei- Heracleum lanatum- Potentilla egedii-Festuca rubra (del Moral and Watson 1978) stipulata-Geranium erianthum (Cooper 1942) (Bank 1951) viviparurn- Erigeron peregrinus ( Bank 1 95 1 ) Geum rnacrophyllum (Shacklette et al. 1969) Epilobium angustifolium Heracleum lanatum- Veratrum viride-Senecio triangularis (Cooper 1942) Heracleum lana tum- A th yrium filix- femina- Angelica lucida/ Cla ytonia sibirica/Cardamine urnbellata-Coptis tri folia/ mosses (Byrd and Woolington 1977) A th yrium filix- femina-Cystopteris fragilis- Bo trychium s p p .. Gymnocarpium dryopteris (Bank 195 1 1 Elymus arenarius (Bank 1951; George et al. 1977; Griggs 1936; Hanson 1953; Klein 1958; Shacklette et al. 1969; Spetzman 1959; Stephens and Billings 1967; Ugolini and Walters 1974; Young 1971) 10 w
Preliminary Classification for Alaska Vegetation (Continued) N P Level IV Level V Level I Level II Level Ill 4. Herba- A. Tall grass (5) Elymus b. Coastal elymus-herb - has approximately the same dis- ceous (continued) (continued) tribution as the coastal elymus type. vegetation (continued) B. Midgrass (1) Dry midgrass c. Dune elymus - is common on dune systems, usually on or near the coast. d. Inland shore elymus - occurs on gravel outwash flats and lake beach ridges on the Seward Peninsula a. Dry elyrnus - is a relatively uncommon type that occurs in the Alaska Range and possibly in interior Alaska and the Brooks Range. b. Grass-shrub - is common on localized, steep, south-facing bluffs in interior and south-central Alaska. c. Dry bluejoint - is a bluejoint type of low stature occur- ring on dry sites, especially near the northern and western limits of the range of bluejoint. d. Dry fescue - occupies dry slopes in interior, south-central, and western Alaska. Elymus arenarius- Honcken ya peploides-Mertensia maritima (Fries 1977; Johnson et al. 1966; Potter 1972; Wiggins and Thomas 1962) Elymus arenarius-Senecio pseudoarnica- Lath yrus maritimus (Bank 1951; Hulten 1960; Rausch and Rausch 1968) Elymus arenarius-Lathyrus maritimus-Poa eminens ( Hanson 1953) Elymus arenarius- Ligusticum scoticum-Anemone narcissiflora (Shacklette et al. 1969) Elymus arenarius- Heracleum lanatum-Cla ytonia sibirica (Byrd and Woolington 1977) Elymus arenarius-Festuca rubra (Palmer and Rouse 1945) Elymus arenarius- Lath yrus maritimus-Senecio pseudoarnica- Elymus arenarius-Polemonium boreale-Senecio pseudoarnica Elymus arenarius-Dryas integrifolia ( Komarkova and Webber Angelica lucida (Fries 1977) (Young and Racine 1978) 1980) Elymus arenarius ( Racine and Anderson 1979) El ymus inno va tus- Fes tuca altaica/Hylocomium splendens Elymus innovatus-Poa glauca (Hanson 1951 (Viereck 1966) Festuca altaica-Salix lanata-Artemisia arctica (Scott 1974) Calamagrostis purpurascens-Artemisia frigida ( Hanson 195 1 ) Festuca altaica- Vaccinium vitis-idaea- V. uliginosum- Dryas Festuca altaica-Empetrum nigrum-Salix reticulata (Scott 1974) octopetala (Hanson 195 1 ) Calamagrostis canadensis (Burns 1964; Hanson 1953; Pegau 1968) Festuca altaica (Hanson 1951, 1953) Festuca altaica-Calamagrostis canadensis (Hanson 1951 )
(2) Mesic a. Midgrass-herb - occupies a variety of sites, from alpine meadows to streambanks. It is found in the Aleutian Islands and in southwestern, south-central, and interior Alaska. midgrass Festuca altaica-Anemone narcissiflora (Anderson 1974; Pegau Festuca altaica-Lupinus arcticus (Scott 1974) Festuca altaica-Carex podocarpa-Aconitum delphinifolium- Mertensia paniculata-Artemisia arctica (Hanson 1951 1 Festuca altaica-Sanguisorba stipulata- Lycopodium alpinum- Salix reticulata/Hypnaceae (Hanson 1951 1 Festuca altaica- Calamagrostis canadensis- Cornus canadensis- Geranium erianthum (Hanson 1951) Fes tuca rubra- Angelica lucida- Achillea borealis- Cardamine umbellata (Byrd and Woolington 1977) Poa eminens-Deschampsia beringensis- Festuca rubra (Shacklette et al. 1969) and Hemming 1972) b. Hair-grass - is common in the Aleutian Islands and along Deschampsia beringensis (Hanson 195 1 1 the southern coast of Alaska. C. Sedge- (1) Wet a. Sedge marsh - occurs primarily in the southern part of grass sedge-grass the State and in the Aleutian Islands. (fresh water) b. Moss-sedge marsh - occurs primarily in southeastern and south-central Alaska and in'the Aleutian Islands. c. Herb marsh - is a rare type that has been reported from the Aleutian Islands. (2) Saline a. Halophytic grass - occurs on sheltered, gently sloping sites with silty substrates along the entire Alaska coast- sedge-grass (tidal marsh) line. b. Halophytic sedge - occurs on sheltered sites along the Alaska coastline. Carex lyngbyaei (Batten et al. 1978; Byrd and Woolington Carex nigricans-C. limosa (Cooper 1942) Carex pluri flora- Trichophorurn caespitosum- Eriophorum russeolum-Polygonum viviparum- Erigeron peregrinus (Bank 1951) Carex rostrata- Eriophorum angusti folium-Calamagrostis canadensis-Cicuta mackenzieana (Young and Racine 1978) Carex lyngbyaei-C. pluriflora-C. anthoxanthea-C. macrochaeta (Shacklette et al. 1969) Carex pluriflora (Batten et al. 1978) Scirpus validus (Batten et al. 1978; del Moral and Watson Carex mackenziei (del Moral and Watson 1978) 1977; Griggs 1936; Hulten 1960) 1978) Scapania paludosa-Nardia scalaris-Marsupella ernarginata Philonotis fontana-Parnassia kotzebuei (Shacklette et al. 1969) Sphagnum teres-S. squarrosum-S. magellanicum-S. cornpacturn- (Shacklette et al. 1969) S. papillosurn-S. girgensohnii (Shacklette et al. 1969) Caltha palustris-Claytonia sibirica (Shacklette et al. 1969) Puccinellia phryganodes (Jefferies 1977) Puccinellia langeana (Griggs 1936) Puccinellia nutkaensis (Batten et al. 1978) Puccinellia grandis (Batten et al. 1978) Carex lyngbyaei (Batten et al. 1978; del Moral and Watson Carex subspathacea (Hanson 1951 ) Carex subspathacea-Puccinellia phryganodes (Webber et al. Carex ramenskii (Batten et al. 1978; Jefferies 1977) Carex ramenskii-Potentilla egedii (George et al. 1977) Eleocharis palustris (del Moral and Watson 1978) 1978; Stephens and Billings 1367) 1978)
N Preliminary Classification for Alaska Vegetation (Continued) a Level I Level II Level Ill Level IV Level V 4. Herba- C. Sedge- (2) Saline c. Halophytic herbs - are generally located seaward from Mertensia maritima-Honckenya peploides (Amu ndsen and ceous grass sedge-grass the band of Elymus arenarius. Clebsch 1971 ; Britton 1967; Griggs 1936; Hanson 1953; vegetation (continued) (tidal marsh) Potter 1972; Spetzman 1959; Thomas 195 1 ) (continued) (continued) Cochlearia officinalis (Wiggins and Thomas 1962) Cochlearia officinalis- Lathyrus maritimus (Bank 1951 ) Cochlearia officinalis-Puccinellia phryganodes (Webber et al. Honckenya peploides-Senecio pseudoarnica (Shacklette et al Cochlearia o fficinalis-Achillea borealis- Draba h yperborea Plan tag0 maritima- Triglochin maritimum-Puccinellia spp. Cochlearia officinalis-Fucus distichus (Batten et al. 1978) Juncus arcticus (del Moral and Watson 1978) 1978) 1969; Young 1971) (Byrd and Woolington 1977) (Batten et al. 1978) (3) Mesic a. Sedge-grass - is found in south-central Alaska and on sedge-grass the Aleutian Islands. b. Sedge - is found on the Aleutian Islands. Calamagrostis canadensis-Carex macrochaeta ( Hanson 195 1 ) Carex macrochaeta-Festuca rubra (Byrd and Woolington 1977) Carex lyngbyaei-C. macrochaeta-Cladina impexa (Shacklette et al. 1969 5. Aquatic A. Freshwater (1) Ponds a. Floating and submerged vegetation - is common through- Ranunculus trichophyllus-Hippuris vulgaris ( Hanson 1953; vegetation and lakes out the State, except rare on the arctic coastal plain. Shacklette et al. 1969) 1960, 1966) Sparganium hyperboreum-Potamogeton perfoliatus ( Hulten Potamogeton spp.-Myriophyllum spicatum (Batten et al. 1978) Ranunculus h yperboreus- R. gmelini- R. trichoph yllus (Johnson Nuphar polysepalum (Batten et al. 1978; Griggs 1936) lsoetes muricata- Ranunculus reptans- Limosella aquatica Siphula ceratites-Scapania paludosa (Shacklette et al. 1969) Suhularia aquatica-Callitriche anceps (Shacklette et al. 1969) et al. 1966) (Shacklette et at. 1969) b. Emergent vegetation - is common throughout the State. Arctophila fulva (Clebsch 1957; Komarkova and Webber 1978, 1980; Potter 1972; Rausch and Rausch 1968; Webber 1978, Webber and Walker 1975; Wiggins and Thomas 1962) Potentilla palustris (Johnson et al. 1966) Arctophila fulva- Hippuris vulgaris- Ranunculus pallasii- Hippuris vulgaris (Potter 1972) Menyanthes trifoliata-Ranunculus pallasii (Webber et al. 1978) Cicu ta mackenzieana- Hippuris vulgaris- Men yan thes trifoliata- Equisetum fluviatile (Hulten 1966)
(2) Streams a. Floating and submerged vegetation - is relatively rare but Fontinalis neomexicana- Ranunculus trichophyllus (Bank 195 1 ; Ranunculus hyperboreus-R. trichophyllus (Griggs 1936) occurs in the southern two-thirds of the State. Shacklette et al. 1969) b. Emergent vegetation - is common throughout the State. Arctophila fulva (Hulten 1966) Potentilla palustris-Men yanthes trifoliata-Caltha palustris (Griggs 1936) B. Saltwater (1) Estuarine (2) Intertidal
Key to Levels I, II, and III of the
Proposed Classification of Alaska Vegetation
Although the classification is based primarily on the vegetation, it was necessary to use
location and site characteristics for key characteristics in some instances. When more quantita-
tive information is available on the plant communities it should be possible to separate the types
based only on vegetation characteristics. Since the aquatic vegetation classification has not been
developed, this key includes only the four terrestrial classes.
1.
1.
2.
2.
3.
3.
4.
4.
5.
5.
6.
6.
7.
7.
8.
8.
9.
9.
10.
10.
11.
11.
12.
12.
13.
13.
Trees present and with canopy cover of 10 percent or more .......... 1 Forest. ... 2.
9.
Over 75 percent of tree cover contributed by
Less than 75 percent of tree cover contributed
Trees absent or nearly so, with less than 10-percent cover .......................
conifer species ..................................... 1 -A Conifer forest .... 3.
by conifer species ...................................................... 5.
Tree canopy of 60- to 1 00-percent cover ................ 1 -A-( 1 ) Closed conifer forest
Tree canopy of less than 60-percent cover ...................................
Tree canopy of 25- to 59-percent cover .................. 1 -A-(2) Open conifer forest
Tree canopy of 10- to 24-percent cover ................... 1 -A-( 3) Conifer woodland
deciduous species ................................. 1 -B Deciduous forest ....
4.
Over 75 percent of tree cover contributed by
6.
Deciduous or conifer species contribute
25 to 74 percent of tree cover ....... 1 -C Mixed conifer and deciduous forest .... 8.
Tree canopy of 60- to 1 00-percent cover .............. 1 -B-( 1 ) Closed deciduous forest
Tree canopy of less than 60-percent cover ................................... 7.
Tree canopy of 25- to 59-percent cover ................ 1 -B-(2) Open deciduous forest
Tree canopy of 10- to 24-percent cover ................. 1 -B-(3) Deciduous woodland
Tree canopy of 60- to 1 00-percent cover ................. 1 -C-( 1 ) Closed mixed forest
Tree canopy of 25- to 59-percent cover ................... 1 -C-( 2) Open mixed forest
at least 25 percent 3 Shrubland and 2-D Shrub tundra .... 10.
if present with less than 25-percent cover. ................................... 14.
Shrubs more than 1.5 meters (5 feet) tall ................. 3-A Tall shrubland .... 12.
Shrubs less than 1.5 meters (5 feet) tall ..................................... 11.
Shrubs associated with typical tundra sedges,
herbs, and mosses. Located in areas above
or beyond the limit of trees ........................... 2-D Shrub tundra. ... 25.
Shrubs not associated with tundra species. Located
adjacent to tree line or in forested region ................ 3-B Lowshrubland. ... 13.
Shrub canopy cover greater than 75 percent ............. 3-A-( 1 ) Closed tall shrubland
Shrub canopy cover greater than 75 percent ............ 3-B-( 1) Closed low shrubland
Vegetation dominated by erect to decumbent
(but not matted) woody shrubs; shrub cover
Vegetation herbaceous or of low, cushionlike shrubs,
less than 20 centimeters (8 inches) in height; taller shrubs
.....................
Shrub canopy cover 25 to 75 percent ................... 3-A-(2) Open tall shrubland
Shrub canopy cover 25 to 75 percent .................. 3-B-(2) Open lowshrubland
28
14.
14.
15.
15.
16.
16.
17.
17.
18.
18.
19.
19.
20.
20.
21.
21.
22.
22.
23.
23.
24.
24.
25.
25.
Vegetation dominated by grass species, primarily
Calamagrostis and Elymus, or if dominated by sedges
and forbs, found primarily within forested areas ...... 4 Herbaceous vegetation .... 27.
Vegetation dominated by sedges and low, matted shrubs;
if grasses are dominant they are typical arctic species,
such as Arctagrostis latifolia or Poa arctica. Found in
areas above and beyond the limit of trees. ....................... 2 Tundra. ... 15.
Tussocks of Eriophorum vaginatum dominant ............ 2-C Tussock tundra .... 16.
Tussock not dominant, vegetation dominated by a
sedge-grass mat, by mat and cushion plants, or by forbs. ........................ 17.
Tussock vegetation without interspersed shrubs ........... 2-C-(1) Sedge tussock tundra
Tussock vegetation with scattered shrubs on and
between the tussocks .......................... 2-C-( 2) Sedge tussock-shrub tundra
Vegetation a sedge-grass mat - not forming tussocks .... 2-A Sedge-grass tundra .... 18.
Vegetation dominated by mat and cushion plants or forbs ....................... 22.
Dominated by sedges and grasses common to wet sites,
primari I y Carex aquatilis, Eriophorum angustifolium, or
Dupontia fischeri, with or without shrubs ............. 2-A-( 1 ) Wet sedge-grass tundra
and 2-A-(3) Sedge-shrub tundra .... 19.
On mesic sites, dominated by sedges, grasses, or
forbs, such as Poa arctica, Arctagrostis latifolia,
Carex microchaeta, Carex nesophila, Carex bigelo wii ........................... 20.
Sedges dominate, but with up to 25-percent cover
of willows or birch .................................. 2-A-(3) Sedge-shrub tundra
Sedges and grasses nearly pure with less than
IO-percent shrub cover ............................ 2-A-( 1 ) Wet sedge-grass tundra
With less than IO-percent cover of low or
matted shrubs .................................. 2-A-( 2) Mesic sedge-grass tundra
With up to 25-percent cover of low shrubs of
birch or willow ..................................... 2-A-(3) Sedge-shrub tundra
With up to 25-percent cover of matted shrubs,
such as Dryas and Arctostaphylos ............. 2-A-(4) Sedge-mat and cushion tundra
Dominated by mat and cushion plants ........... 2-E Mat and cushion tundra .... 23.
Dominated by forbs ............................. 2-B Herbaceous tundra .... 24.
At least 75 percent or more of the surface
covered with plants ........................ 2-E-(2) Closed mat and cushion tundra
Less than 75 percent of the surface covered
with plants ................................ 2-E-( 1 ) Open mat and cushion tundra
Seral communities at low elevations in
tundra areas - limited distribution ........... 2-B-(1) Lowelevation herbaceous tundra
Snow beds, cliffs, and scree slopes in
alpine tundra areas - a diverse group ............... 2-B-(2) Alpine herbaceous tundra
Dominated by low willows ........................... 2-D-( 1) Willow shrub tundra
Dominated by birch, ericaceous shrubs, or
a mixture of shrub species ............................................... 26.
With 10- to 25-percent cover of low or matted shrubs .......................... 21.
29
Key, continued
26.
26.
27.
27.
28.
28.
29.
29.
30.
30.
31.
31.
32.
32.
33.
33.
34.
34.
35.
35.
Dominated by birch and ericaceous shrubs .... 2-D-(2) Birch and ericaceous shrub tundra
Dominated by birch, ericaceous shrubs,
and willows ....................................... 2-D-(3) Mixedshrub tundra
Dominated by grasses but with occasional forbs and sedges ...................... 30.
Dominated by a nearly equal mixture of sedges,
grasses, and forbs ............................ 4-C Herbaceous sedge-grass .... 28.
On wet sites, usually with some standing water
On mesic sites ........................................ 4-C-(3) Mesic sedge-grass
Growing in fresh water ........................ 4-C-( 1) Wet sedge-grass (fresh water)
Growing in salty or brackish water ............. 4-C-(2) Saline sedge-grass (tidal marsh)
Grasses at maturity over 1 meter (3.3 feet) in height ........ 4-A Ta// grass/and .... 31.
Grasses at maturity less than 1 meter (3.3 feet) in height ........................ 35.
Dominants are species of Ca/amagrostis ..................................... 32.
Dominants are Elymus and herbs .......................................... 34.
Grass mixed with at least 25-percent herbs and shrubs .......................... 33.
Grasses mixed with at least 25-percent herbs .................. 4-A-( 2) Bluejoint-herb
Dominant cover is Elymus arenarius .............................. 4-A-(5) Elymus
Dominant cover is herbs ........................................ 4-A-(4) Herbs
Found on dry, usually south-facing slopes ..................... 4-B-( 1) Dry midgrass
Found on mesic sites .................................... 4-B-(2) Mesic midgrass
............................... 29.
Grass species nearly pure with less than 25-percent herbs ............. 4-A-( 1) Bluejoint
Grasses mixed with at least 25-percent cover of shrubs ......... 4-A-(3) Bluejoint-shrub
J
30
References
Alaback, Paul B. 1980. Provisional plant community types of southeast Alaska. 15 p. Unpub-
lished rep. on file at USDA For. Serv., Inst. North. For., Fairbanks, Alaska.
Amundsen, C. C. 1972. Amchitka bioenvironmental program. Plant ecology of Amchitka Island.
Final Rep., 27 p. and 2 appendixes and maps. Batelle, Columbus Lab., Columbus, Ohio.
Amundsen, C. C., and E. E. C. Clebsch. 1971. Dynamics of the terrestrial ecosystem vegetation
of Amchitka Island, Alaska. Bioscience 21 (12):619-623.
Anderson, J. H. 1972. Phytocenology and primary production at Eagle Summit, Alaska. ln
Proceedings tundra biome symposium, p. 61 -69. Lake Wilderness Cent., Univ. Wash., U.S.
Tundra B iome.
Anderson, J. H. 1974. Plants, soils, phytocenology and primary production of the Eagle Summit
tundra biome site. U.S. Tundra Biome Ecosyst. Anal. Stud. Data Rep. 7442. U.S. Int. Biol.
Program, Arctic Res. Program.
Bailey, Robert G., Robert D. Pfister, and Jan A. Henderson. 1978. Nature of land and resource
classification - a review. J. For. 76( 10) :650-655.
Bank, Theodore P., I I. 1951. Botanical and ethnobotanical studies in the Aleutian Islands, I.
Aleutian vegetation and Aleut culture. Mich. Acad. Sci., Arts, & Lett. 37: 13-30.
Batten, A. R. 1977. The vascular floristics, major vegetation units, and phytogeography of the
Lake Peters area, northeastern Alaska. M.S. thesis. Univ. Alaska. 330 p.
Batten, A. R., S. Murphy, and D. F. Murray. 1978. Definition of Alaskan coastal wetlands by
floristic criteria. 490 p. Final report to U.S. Environ. Prot. Agency, Corvallis Environ. Res.
Lab., Corvallis, Oreg. On file at the Univ. Alaska Herb., Fairbanks, Alaska.
Batten, A. R., D. F. Murray, and J. C. Dawe. 1979. Threatened and endangered plants in
selected areas of the Fortymile Planning Unit Alaska. BLM-Alaska Tech. Rep. 3, 127 p.
U.S. Dep. Inter. Bur. Land Manage., Alaska State Off., Anchorage.
Bliss, L. C., and J. E. Cantlon. 1957. Succession on river alluvium in northern Alaska. Am. Midl.
Nat. 58( 2) :452-469.
Britton, M. E. 1967. Vegetation of the arctic tundra. ln Arctic biology. 2d ed. p. 67-130.
H. P. Hansen, ed. Oreg. State Univ. Press, Corvallis.
Buckley, John L., and Wilbur L. Libby. 1957. Research and reports on aerial interpretation of
terrestrial bioenvironments and faunal populations. U.S. Air Force Aeromed. Lab. Rep.
57-32, 105 p. Fairbanks, Alaska.
Buckley, John L., and Wilbur L. Libby. 1959. The distribution in Alaska of plant and animal
life available for survival. U.S. Air Force Aeromed. Lab. Tech. Rep. 58-10, 43 p. Fairbanks,
Alaska.
31
Burns, John J. 1964. Pingos in the Yukon-Kuskokwim Delta, Alaska: Their plant succession and
use by mink. Arctic 17(3):203-210.
Byrd, G. V., and D. W. Woolington. 1977. Breeding biology, habitat utilization, and population
structure of Aleutian Canada geese. 140 p. Draft report to U.S. Fish and Wildl. Serv.,
Aleutian Isl. Natl. Refuge.
Childs, H. E., Jr. 1969. Birds and mammals of the Pitmegea River region, Cape Sabine, north-
western Alaska. Biol. Pap. 10, 76 p. Univ. Alaska, Fairbanks.
Churchill, E. D. 1955. Phytosociological and environmental characteristics of some plant
communities in the Umiat region of Alaska. Ecology 36(4) :606-627.
Clebsch, E. E. C. 1957. The summer season climatic and vegetational gradient between Point
Barrow and Meade River, Alaska. M.S. thesis. Univ. Tenn. 60 p.
Cooper, William S. 1939. A fourth expedition to Glacier Bay, Alaska. Ecology 20(2): 130-155.
Cooper, William S. 1942. Vegetation of the Prince William Sound region, Alaska, with a brief
excursion into post-Pleistocene climatic history. Ecol. Monogr. 12( 1 ): 1-22.
Cooper, William Skinner. 1924. The forest of Glacier Bay, Alaska: Present, past, and yet unborn.
J. For. 22( 1 ) : 16-23.
Crocker, Robert, and Jack Major. 1955. Soil development in relation to vegetation and surface
age at Glacier Bay, Alaska. J. Ecol. 43(2):427-448.
Crum, H. A., W. C. Steere, and L. E. Anderson. 1973. A new list of mosses of North America
north of Mexico. Bryologist 76( 1 ) :85-130.
Davis, Lawrence S., and Jan A. Henderson. 1976. A classification and information system for
management of wildland ecosystems: The conceptual framework. Dep. For. and Outdoor
Recreation, 54 p. Utah State Univ., Logan.
Dean, Frederick C. 1964. Biological investigations of the Baird and Schwatka Mountains,
Brooks Range, Alaska, 1963. 130 p. Univ. Alaska, College [Fairbanks] .
Dean, Frederick C., and David L. Chesemore. 1974. Studies of birds and mammals in the Baird
and Schwatka Mountains, Alaska. Biol. Pap. 15, 80 p. Univ. Alaska, Fairbanks.
del Moral, Roger, and Alan F. Watson. 1978. Vegetation on the Stikine Flats, southeast Alaska.
Northwest Sci. 52(2): 137-1 50.
Dennis, John. 1969. Growth of tundra vegetation in relation to arctic micro-environments at
Barrow, Alaska. Ph. D. thesis. Duke Univ., Durham, N.C. 289 p.
Drew, J. W., and R. E. Shanks. 1965. Landscape relationships of soils and vegetation in the
forest-tundra ecotone, upper Firth River Valley, Alaska-Canada. Ecol. Monogr. 35(3) : 285-306.
Drury, W. H., Jr. 1956. Bog flats and physiographic processes in the upper Kuskokwim River
region, Alaska. Contrib. Gray Herb. Harvard Univ. 178, 130 p. Cambridge, Mass.
32
Everett, K.R. 1971. Composition and genesis of the organic soils of Amchitka Island, Aleutian
Islands, Alaska. Arct. and Alp. Res. 3(1):1-16.
Foote, M. Joan. 1976. Classification, description and dynamics of plant communities following
fire in the taiga of interior Alaska. Final rep. for Bur. Land Manage. 21 1 p. On file at USDA
For. Serv., Inst. North. For., Fairbanks, Alaska.
Fosberg, F. R. 1967. A classification of vegetation for general purposes. Guide to the checklist
for IBP areas. G. F. Peterkin, ed. IBP Handb. 4, p. 73-133. Blackwell Sci. Publ., Oxford.
Fries, J. A. 1977. The vascular flora of Nunivak Island, Alaska. 58 p. Senior thesis proj., Environ.
Stud. Dep., Middlebury Coll., Middlebury, Vt.
George, T. H., W. J. Stringer, J. E. Preston, W. R. Fibich, and P. C. Scorup. 1977. Reindeer
range inventory in western Alaska from computer-aided digital classification of LAN DSAT
data. 28th Alaska Sci. Conf., Alaska Div. AAAS, Sept. 22-24, Tech. Sess. Pap. 4, p. 98-1 15.
Anchorage.
Gjaerevoll, 0. 1954. Kobresieto-Dryadion in Alaska. Nytt Mag. Bot. 3:51-54.
Griggs, Robert F. 1936. The vegetation of the Katmai district. Ecology 17(3):380-417.
Hale, M. E., Jr., and W. L. Culberson. 1970. A fourth checklist of the lichens of the continental
United States and Canada. Bryologist 73(3) :499-543.
Hanson, H. C. 1950. Vegetation and soil profiles in some solifluction and mound areas in Alaska.
Ecology 31 (4) :606-630.
Hanson, H. C. 1951. Characteristics of some grassland, marsh, and other plant communities in
western Alaska. Ecol. Monogr. 21 (4):317-378.
Hanson, H. C. 1953. Vegetation types in northwestern Alaska and comparisons with communi-
ties in other arctic regions. Ecology 34( 1): 11 1-140.
Harris, Arland S. 1965. Subalpine fir on Harris ridge near Hollis. Northwest Sci. 39(4):123-128.
Hettinger, L. R., and A. J. Janz. 1974. Vegetation and soils of northeastern Alaska. Arct. Gas
Biol. Rep. Ser. 21, 206 p. North. Eng. Serv., Co., Ltd., Edmonton, Can.
Heusser, C. J. 1954. Nunatak flora of the Juneau Ice Alaska. Bull. Torrey Bot. Club
8 1 (3) : 236-250.
Heusser, C. J. 1960. Late-Pleistocene environments of North Pacific North America. Am. Geogr.
Soc. Spec. Publ. 35, 308 p.
Hjeljord, 0. G. 1971. Feeding ecology and habitat preference of the mountain goat in Alaska.
M.S. thesis. Univ. Alaska, Fairbanks. 126 p.
Hopkins, D. M., and R. S. Sigafoos. 1951. Frost action and vegetation patterns on Seward
Peninsula, Alaska. U.S. Geol. Surv. Bull. 974-C, p. 51-100.
Hulten, E. 1960. Flora of the Aleutian Islands. 2d ed. 376 p. J. Cramer, Weinheim.
33
Hulten, E. 1962. Flora and vegetation of Scammon Bay, Bering Sea Coast, Alaska. Sven. Bot.
Tidskr. 56( 1 ) :36-54.
Hulten, E. 1966. Contributions to the knowledge of flora and vegetation of the southwestern
Alaskan mainland. Sven. Bot. Tidskr. 60( 1 ): 175-1 89.
Hulten, E. 1968. Flora of Alaska and neighboring territories. Stanford Univ. Press, Stanford,
Calif. 1,008 p.
Isleib, M. D., and B. Kessel. 1973. Birds of the North Gulf Coast-Prince William Sound region,
Alaska. Biol. Pap. 14, 149 p. Univ. Alaska, Fairbanks.
Jaques, D. R. 1973. Reconnaissance botany of alpine ecosystems on Prince of Wales Island,
southeast Alaska. M.S. thesis. Oreg. State Univ., Corvallis. 133 p.
Jefferies, R. L. 1977. The vegetation of salt marshes at some coastal sites in arctic North
America. J. Ecol. 65(2) :661-672.
Johnson, A. W., L. A. Viereck, R. E. Johnson, and H. Melchior. 1966. Vegetation and flora of
the Cape Thompson-Ogotoruk Creek area, Alaska. ln Environment of the Cape Thompson
region, Alaska. N. J. Wilimovsky and J. N. Wolfe, eds. U.S. At. Energy Comm. Div. Tech. Inf.
PNE-481, p. 277-354. Oak Ridge, Tenn.
Johnson, Phillip L., and Larry L. Tiezen. 1973. Vegetative research in arctic Alaska. ln Alaskan
arctic tundra. Max E. Britton, ed. Arct. Inst. North Am. Tech. Pap. 25, p. 169-198.
Joint Federal-State Land Use Planning Commission for Alaska. 1973. Major ecosystems of
Alaska. (Map.) U.S. Geol. Surv., Fairbanks, Alaska; Denver, Colo.; and Washington, D.C.
Juday, Glenn P., Paul Alaback, and AI Harris. 1979. The distribution and performance of Pacific
silver fir (Abies amabilis (Dougl.) Forbes) in southeast Alaska. Unpublished data on file at
USDA For. Serv., Inst. North. For., Fairbanks, Alaska.
Kessel, B., and G. B. Schaller. 1960. Birds of the upper Sheenjek Valley, northeastern Alaska.
Biol. Pap. 4, 59 p. Univ. Alaska, Fairbanks.
Klein, D. R. 1958. Saint Matthew Island reindeer-range studies. U.S. Fish and Wildl. Serv., Fed.
Aid Wildl. Job Completion Rep., Job 6, Proj. W-3-R-12, work plan B, 39 p. Juneau, Alaska.
Klein, D. R. 1965. Ecology of deer range in Alaska. Ecol. Monogr. 35(3):259-284.
Komarkova, V., and P. J. Webber. 1978. Geobotanical mapping, vegetation disturbance and
recovery. ln Tundra disturbances and recovery following the 1949 exploratory drilling, Fish
Creek, northern Alaska. D. E. Lawson, J. Brown, K. R. Everett, and others. U.S. Army
CRREL Rep. 78-28, p. 41-51. Hanover, N.H.
Komarkova, V., and P. J. Webber. 1980. Two low arctic vegetation maps near Atkasook, Alaska.
Arct. and Alp. Res. 12(3) [In press.]
Koranda, J. J. 1960. The plant ecology of the Franklin Bluffs area, Alaska. Ph. D. thesis.
Univ. Tenn., Knoxville. 234 p.
34
Koranda, John J., and Charles D. Evans. 1975. A discussion of sites recommended as potential
natural landmarks in the Arctic Lowland Natural Region, northern Alaska. Tundra Biome
Cent., 189 p. Univ. Alaska, Fairbanks.
Kuchler, A. W. 1969. Potential natural vegetation of Alaska. U.S. Geol. Surv. Natl. Atlas Map 89.
LaPerriere, A. 1979. Letter to L. A. Viereck on file at USDA For. Serv., Inst. North. For.,
Fairbanks, Alaska.
LaRoi, George H. 1967. Ecological studies in the boreal spruce-fir forests of the North Ameri-
can taiga. 1. Analysis of the vascular flora. Ecol. Monogr. 37(3):229-253.
Lawrence, Donald B. 1958. Glaciers and vegetation in southeastern Alaska. Am. Sci. 46(2):89-122.
Lutz, H. J. 1956. Ecological effects of forest fires in the interior of Alaska. USDA For. Serv.,
Alaska For. Res. Cent. Tech. Bull. 1133, 121 p.
Murray, David F., and Alan R. Batten. 1977. A provisional classification of Alaskan tundra.
134 p. Unpublished report on file at USDA For. Serv., Inst. North. For., Fairbanks, Alaska.
Neiland, Bonita J. 1971. The forest bog complex of southeast Alaska. Vegetatio, Acta Geobot.
22( 1-3) : 1-64.
Neiland, Bonita J., and Leslie A. Viereck. 1977. Forest types and ecosystems. Proceedings of
symposium North American forest lands at latitudes north of 60 degrees, p. 109-136. Univ.
Alaska, Fairbanks.
Nodler, F. A., A. J. LaPerriere, and D. R. Klein. 1978. Vegetation type mapping in northwestern
Alaska in relation to caribou and reindeer range potentials. Alaska Coop. Wildl. Res. Unit
Spec. Rep. 2, 33 p. Univ. Alaska, Fairbanks.
Palmer, L. J. 1942. Major vegetative types of southeastern Alaska. Unpublished report prepared
by U.S. Fish and Wildl. Serv., Juneau, Alaska. 16 p. On file at USDA For. Serv., Inst. North.
For., Fairbanks, Alaska.
Palmer, L. J., and C. H. Rouse. 1945. Study of the Alaska tundra with reference to its reactions
to reindeer and other grazing. U.S. Fish and Wildl. Serv. Res. Rep. 10, 48 p. Juneau, Alaska.
Pegau, R. E. 1968. Reindeer range appraisal in Alaska. M.S. thesis. Univ. Alaska, Fairbanks.
130 p.
Pegau, R. E., and J. E. Hemming. 1972. Caribou report. Vol. 12. 216 p. Proj. Prog. Rep., Fed.
Aid Wildl. Restoration, Proj. W-17-2 and W-1 7-3. Alaska Dep. Fish and Game, .Juneau.
Potter, L. D. 1972. Plant ecology of the Walakpa Bay area, Alaska. Arctic 25(2):115-130.
Racine, Charles H. 1976. Flora and vegetation. ln Biological survey of the proposed Kobuk
Valley National Monument, p. 39-139. Herbert Melchior, ed. U.S. Dep. Inter. Natl. Park Serv.
On file at USDA For. Serv., Inst. North. For., Fairbanks, Alaska.
35
Racine, Charles H. 1977. Tundra disturbance resulting from a 1974 drilling operation in the
Cape Espenberg area, Seward Peninsula, Alaska. Report prepared for U.S. Natl. Park Serv.
Ord. PX 9100-6-140. 47 p. On file at USDA For. Serv., Inst. North. For., Fairbanks, Alaska.
Racine, Charles H., and J. H. Anderson. 1979. Flora and vegetation of the Chukchi-Imuruk area.
ln Biological survey of the Bering Land Bridge National Monument, p. 38-1 13. Herbert R.
Melchior, ed. Alaska Coop. Park Stud. Unit, Univ. Alaska, Fairbanks.
Racine, Charles H., and S. B. Young. 1978. Ecosystems of the proposed Lake Clark National
Park, Alaska. Contrib. Cent. North. Stud. 16, 232 p. Wolcott, Vt.
Rausch, R. L., and V. R. Rausch. 1968. On the biology and systematic position of Microtus
abbreviatus Miller, a vole endemic to the St. Matthew Islands, Bering Sea. Z. Saeugetierkd.
33( 2) :65-99.
Reid, David E. 1974. Vegetation of the Mackenzie Valley: Part One. Arct. Gas Biol. Rep. Ser.
Vol. 3, 156 p. North Eng. Serv. Co., Ltd., Edmonton, Can.
Scott, R. W. 1972. Ecology and phytogeography of alpine vegetation in the southeastern
Wrangell Mountains, Alaska. Ph. D. thesis. Univ. Mich., Ann Arbor. 314 p.
Scott, R. W. 1974. Alpine plant communities of the southeastern Wrangell Mountains, Alaska.
ln lcefield Ranges research project, scientific results. Vol. 4. p. 283-306. V. C. Bushnell and
M. G. Marcus, eds. Am. Geogr. Soc., New York.
Shacklette, Hansford T., and others. 1969. Vegetation of Amchitka Island, Aleutian Islands,
Alaska. US. Geol. Surv. Prof. Pap. 648, 66 p. U.S. Gov. Print. Off., Washington, D.C.
Spetzman, Lloyd A. 1959. Vegetation of the Arctic Slope of Alaska. U.S. Geol. Surv. Prof. Pap.
302-B, 58 p. U.S. Gov. Print. Off., Washington, D.C.
Spetzman, Lloyd A. 1963. Terrain study of Alaska, Part V: Vegetation. ln Engineering intelli-
gence study EIS 301. U.S. Dep. Army, Off. Chief Eng., Washington, D.C.
Stephens, F. R., and R. F. Billings. 1967. Plant communities of a tide-influenced meadow on
Chichagof Island, Alaska. Northwest Sci. 41 (4): 178-183.
Stephens, F. R., C. R. Gass, R. F. Billings, and D. E. Paulson. 1969. Soils and associated
ecosystems of the Tongass. 67 p. Reg. 10, USDA For. Serv., Juneau. Unpublished report on
file at USDA For. Serv., Inst. North. For., Fairbanks, Alaska.
Streveler, G. P., and B. P. Paige. 1971. The natural history of Glacier Bay National Monument,
Alaska. 89 p. U.S. Natl. Park Serv., Glacier Bay Natl. Monument.
Streveler, G. P., I. A. Worley, C. J. Terry, and R. J. Gordon. 1973. Dixon Harbor biological
survey, final report on the summer phase of 1973 research. 241 p. U.S. Natl. Park Serv.,
Glacier Bay Natl. Monument.
Tatewaki, M., and Y. Kobayashi. 1934. A contribution to the flora of the Aleutian Islands.
J. Fac. Agric. Hokkaido Imp. Univ. 36, 119 p. Hokkaido, Jap.
36
Thomas, J. H. 1951. A collection of plants from Point Lay, Alaska. Contrib. Dudley Herb.
Stanford Univ. 4(3) :53-56.
Ugolini, F. C., and J. Walters. 1974. Pedological survey of the Noatak River basin. ln The
environment of the Noatak River basin, Alaska. S. B. Young, ed. Contrib. Cent. North.
Stud. 1, p. 86-1 56. Wolcott, Vt.
Viereck, Leslie A. 1962a. Alaska wildlife investigations, sheep and goat investigations, range
survey. Alaska Dep. Fish and Game, Fed. Aid Wildl. Job Completion Rep., Res. Proj.
Segment, Job 2-A, Proj. W-6-R-3, work plan E, 21 p. Juneau.
Viereck, Leslie A. 1962b. Plant succession and soil development on gravel outwash of the
Muldrow Glacier, Alaska. Ph. D. thesis. Univ. Colo., Boulder. 145 p.
Viereck, Leslie A. 1963. Alaska wildlife investigations, sheep investigations, survey of range
ecology. Alaska Dep. Fish and Game, Fed. Aid Wildl. Segment Rep., Job 2-A, Proj. W-6-R-4,
work plan E. Juneau.
Viereck, Leslie A. 1966. Plant succession and soil development on gravel outwash of the
Muldrow Glacier, Alaska. Ecol. Monogr. 36(3): 181-199.
Viereck, Leslie A. 1970a. Forest succession and soil development adjacent to the Chena River in
interior Alaska. Arct. and Alp. Res. 2( 1 ): 1-26.
Viereck, Leslie A. 1970b. Preliminary investigation of vegetation types surrounding Lake
Aleknagik, Wood River Lakes, Alaska. 18 p. Office report on file at USDA For. Serv., Inst.
North. For., Fairbanks, Alaska.
Viereck, Leslie A. 1975. Forest ecology of the Alaska taiga. Proceedings of the Circumpolar
Conference on Northern Ecology, Ottawa, Can., Sept. 15-18, 1975, p. I-1 to 1-22. Can. Natl.
Comm. Sci. Comm. Probl. Environ. Natl. Res. Counc. Can.
Viereck, Leslie A. 1979. Characteristics of treeline plant communities in Alaska. Holarctic Ecol.
2(4) :228-238.
Viereck, Leslie A., and Elbert L. Little, Jr. 1972. Alaska trees and shrubs. U.S. Dep. Agric.
Agric. Handb. 410, 265 p.
Ward, R. T. 1957. Some ecological notes on the alpine tundra in the area of the Juneau Ice
Field. Proc. Iowa Acad. Sci. 64: 113-1 26.
Webber, P. J. 1978. Spatial and temporal variation of the vegetation and its productivity,
Barrow, Alaska. ln Vegetation and production ecology of an Alaskan arctic tundra, p. 37-1 12.
L. L. Tieszen, ed. Springer-Verlag, New York.
Webber, P. J., V. Komarkova, D. A. Walker, and E. Werbe. 1978. Project 2. Vegetation mapping
and response to disturbance along the Yukon River-Prudhoe Bay Haul Road. ln Ecological
investigations along the Yukon River-Prudhoe Bay Haul Road, Alaska. J. Brown, ed.
U.S. Army CRREL Spec. Rep. 78-13, p. 25-87. Hanover, N.H.
37
Webber, P. J., and D. A. Walker. 1975. Vegetation and landscape analysis at Prudhoe Bay,
Alaska: A vegetation map of the Tundra Biome study area. ln Ecological investigations of the
Tundra Biome in the Prudhoe Bay region, Alaska. J. Brown, ed. Biol. Pap. Univ. Alaska
Spec. Rep. 2, p. 81-91.
White, R. G., B. R. Thompson, T. Skogland, S. J. Person, D. E. Russell, D. F. Holleman, and
J. R. Luick. 1975. Ecology of caribou at Prudhoe Bay, Alaska. ln Ecological investigations of
the Tundra Biome in the Prudhoe Bay region, Alaska. J. Brown, ed. Biol. Pap. Univ. Alaska
Spec. Rep. 2, p. 151-201.
Wiggins, I. L. 1951. The distribution of vascular plants on polygonal ground near Point Barrow,
Alaska. Contrib. Dudley Herb. 4(3) :41-56. Stanford Univ.
Wiggins, I. L., and J. H. Thomas. 1962. A flora of the Alaskan Arctic Slope. Arct. Inst. Spec.
Publ. 4, 425 p. Univ. Toronto Press, Toronto.
Williamson, F. S. L., and L. J. Peyton. 1962. Faunal relationships of birds in the lliamna Lake
area, Alaska. Biol. Pap. 5, 73 p. Univ. Alaska, Fairbanks.
Worley, I. A. 1970. A checklist of the Hepaticae of Alaska. Bryologist 73( 1 ) :32-38.
Worley, I. A. 1977. Plant community analysis. ln Dixon Harbor biological survey, p. 126-239.
G. P. Steveler and I. A. Worley. Natl. Park Serv., Juneau.
Worley, Ian A., and Dennis Jaques. 1973. Subalpine fir in coastal western North America.
Northwest Sci. 47(4) :265-273.
Young, S. B. 1971. The vascular flora of St. Lawrence Island with special reference to floristic
zonation in the arctic regions. Contrib. Gray Herb. Harvard Univ. 201, 115 p.
Young, S. B. 1974. Vegetation of the Noatak Valley, Alaska. ln The environment of the Noatak
River basin, Alaska. S. B. Young, ed. Contrib. Cent. North. Stud. 1, p. 58-84. Wolcott, Vt.
Young, S. B., and C. H. Racine. 1977. Vegetational and floristic analysis and discussion of the
quaternary environment of the Kobuk Valley. 47 p. Report to the US. Natl. Park Serv.
Cent. North. Stud., Wolcott, Vt.
Young, S. B., and C. H. Racine. 1978. Ecosystems of the proposed Katmai western extension,
Bristol Bay lowlands, Alaska. Contrib. Cent. North. Stud. 15, 94 p. Wolcott, Vt.
GPO 990-493
38
The FOREST SERVICE of the U.S. Department of Agriculture is dedicated
to the principle of multiple use management of the Nation’s forest resources
for sustained yields of wood, water, forage, wildlife, and recreation.
Through forestry research, cooperation with the States and private forest
owners, and management of the National Forests and National Grasslands, it
strives - as directed by Congress - to provide increasingly greater service to
a growing Nation.
The U.S. Department of Agriculture is an Equal Opportunity Employer.
Applicants for all Department programs will be given equal consideration
without regard to age, race, color, sex, religion, or national origin.