Loading...
HomeMy WebLinkAboutEffects of Forest Fires on the Winter Range of Barren Ground Caribou 1964s SK 471 .A2 A637 ser.1 no.18 SERIES 1. NUMBER 18 Effects of Forest Fires on the Winter Range of Barren-ground CARIBOU in Northern Saskatchewan by George Wilby Scotter • ..... 1.0 N ..... co ...,. 0 0 0 1.0 1.0 1""-o M M Effects of Forest Fires on the Winter Range of BARREN-GROUND CARIBOU in Northern Saskatchewan by George Wilby ScoHer ARLIS Alaska Resources Library & Information Services Anchorage. Alaska • Canadian Wildlife Service Wildlife Management Bulletin, Series 1, No. 18 .. National Parks Branch Department of Northern Affairs and National Resources SK '171 ,I}~ 4651 .· .Se.r. 1 1\o. I~ Issued under the authority of the · HONOURABLE ARTHUR LAING, P.C., M.P., B.S.A., Minister of Northern Affairs and National Resources Roger Duhamel, F.R.S.C., Queen's Printer and Controller of Stationery, Ottawa 1964 Cat. No. R.65-1/18 j ACKNOWLEDGEMENTS I wish to express my sincere thanks to several people and agencies for tecJmical assistance, field assistance, and for assistance in preparation of this paper. Dr. J. W. Thomson, University of Wisconsin, Dr. H. A. Crum, National Herbarium of Canada, and the staff of the Plant Research Institute, Canada Department of Agriculture, identified or verified identifications of the· lichens, bryophytes, and vascular plants, respectively. The Soil Survey Research Branch of the Canada Department of Agriculture at Edmonton, Alberta, in co-operation with the Research Council of Alberta, made chemical and pH determinations on soil samples. Staff members of the Edmonton office of the Canadian Wildlife Service provided assistance, guidance, and encouragement throughout the study. Dr. L.A. Stoddart, Dr. D. L. Goodwin, Dr. G. H. Kelker, and Professor A. H. Holmgren, members of my graduate committee at Utah State University, made many helpful suggestions on the .. preparation of portions of this paper submitted as a thesis. Mr. L. E. Erickson endured long hours, poor food, and hordes of black flies and mosquitoes without complaint while rendering capable field assistance. My wife, Etta, provided aid in many ways. To all these people and to others too numerous to mention, the writer expresses his thanks. GEORGE W. SCOTTER. CONTENTS LIST OF TABLES, 7 LIST OF FIGURES, 8 FIGURES, 9 INTRODUCTION, 36 DESCRIPTION OF THE STUDY AREA, 38 Location, 38 Geology and topography, 38 Climate, 40 Flora, 41 Fauna, 41 Grazing use, 41 Human use, 41 EXTENT AND HISTORY OF FOREST FIRES, 42 History of fire on caribou ranges in North America, 42 Extent of fire in and near the study area, 43 FORAGE UTILIZATION AND TERRESTRIAL FORAGE PRODUCTION, 45 Method, 45 Forage utilization, 46 Forage production, 47 ARBOREAL LICHEN PRODUCTION, 51 Method, 51 Lichen production and availability, 52 Lichen utilization, 55 Lichen ecology, 56 PLANT SUCCESSION FOLLOWING FOREST FIRES, 57 Method, 57 Bryophytes, 57 Lichens, 58 5 ,, Vascular plants, 62 Succession of tree species, 64 Jack pine, 64 White birch, 65 Black spruce, 65 EFFECTS OF FOREST FIRES ON SOIL PROPERTIES, 67 Description of sample sites, 67 Methods, 68 Physical properties, 68 Chemical properties, 68 Unincorporated organic matter, 69 Effect on physical properties, 69 Soil temperature, 69 Infiltration rate, 71 Erosion, 71 Effect on chemical properties, 72 Soil nutrients, 72 Soil pH, 74 Effect on unincorporated organic matter, 75 EFFECTS OF FIRE ON WILDLIFE, 76 Method, 76 Big game animals, 76 Fur-bearing animals, 78 Birds, 78 SUMMARY AND CONCLUSIONS, 79 SOMMAIRE ET CONCLU~ION, 81 LITERATURE CITED, 83 j APPENDICES, 87 Appendix A: Checklist of the flora on the barren-ground caribou winter range of northern Saskatchewan, 87 · Appendix B: Checklist of vertebrate fauna on the barren-ground caribou winter range of northern Saskatchewan, 92 Appendix C: Canadian Wildlife Service weight-estimate field write-up sheet, 94 Appendix D: Forage productivity in white birch and black spruce forests in various age classes, 96 Appendix E: Forage productivity in jack pine forests of various ages, 108 MAP OF THE STUDY AREAS, INSIDE REAR COVER I 6 il ~~ LIST OF TABLES \I 1 Weather data from Beaverlodge Lake; Saskatchewan, 1956, 39 2 Weather data from Brochet, Manitoba, 1956, 40 3 Average annual rate of forest destruction by fire, expressed in acres per year, 44 4 Average productivity in pounds per acre of air-dry forage by age classes in black spruce and white birch forests, 48 5 Average productivity in pounds per acre of air-dry forage in jack pine forests, 49 6 Air-dry weight of arboreal lichens removed from black spruce trees, 53 7 Air-dry weight of arboreal lichens removed from jack pine trees, 53 8 Productivity of arboreal lichens per acre of mature black spruce forest (air-dry weight), 54 9 Productivity of arboreal lichens per acre of mature jack pine forest (air-dry weight), 55 10 Dominant bryophytes present in three successional stages following forest fires, 58 11 Dominant lichens present in three successional stages following forest fires, 59 12 Annual linear growth rates of Cladonia alpestris and C. rangiferina at four locations in black spruce forests of northern Saskatchewan, 61 13 Annual linear growth increase of Cladonia as reported by various workers, 62 14 Dominant vascular plants in three successional stages following fire in black spruce forests, 64 15 Description of soil colour and texture at sample sites, 68 16 Temperatures in burned-over and unburned soil with differences tested by means of at-test, 70 17 Water infiltration rates on burned-over and unburned soil, 71 18 Chemical soil properties on burned-over and unburned soil, 72 19 Soil pH in burned-over and unburned soils, 74 20 Average number of caribou and moose pellet groups per acre in six black spruce and white birch age classes, 77 21 Average number of caribou and moose pellet groups per acre in jack pine forests of various ages, 77 22 Air-dry forage in recently burned forests 1 to 10 years of age, 96 23 Air-dry forage in forests 11 to 30 years of age, 98 24 Air-dry forage in forests 31 to 50 years of age, 100 25 Air-dry forage in forests 51 to 75 years of age, 102 26 Air-dry forage in forests 76 to 120 years of age, 104 27 Air-dry forage in forests over 120 years of age, 106 28 Air-dry forage in six jack pine forests, 108 7 LIST OF FIGURES 1 This randomly selected plot covered an area of 9.6 square feet in a mature black spruce forest. Note the dense lichen cover, 10 2 Species occurring in each plot were separated and weighed using gram scales, 11 3 After a training period, forage weights were estimated. Estimates were checked daily, 12 4 Five years after a fire at Marchant Lake there was still no lichen cover. (Compare with Figure 5), 13 5 Mature black spruce forests at Marchant Lake support a dense layer of bryophytes and lichens, 14 6 Forest fires destroy organic material and expose bare rock (Father Lake), 15 7 Several decades will be required before such exposed areas will again support tree growth, 16 8 Fireweed and bryophytes are some of the early pioneers at Oblate Lake following forest fires (Compare with Figure 9), 17 9 Mature black spruce forests at. Oblate Lake support a good cover of slow-growing lichens, 18 10 Dense stands of white birch replace black spruce forests following fire (Higginson Lake), 19 11 Succession of understory vegetation following fire in jack pine forest was similar to that occurring in burned-over black spruce forests (Newnham Lake), 20 12 Dense covers of lichens were present iri mature jack pine forests (Black Lake). The lichens, however, were considerably shorter than similar species in black spruce forests, 21 · 13 Thin bark and flammable foliage near the ground make black spruce trees very susceptible to destruction by forest fires, 22 14 Sprouting of dormant buds on the enlarged base of the bole was common in fire- destroyed white birch tr,ees. White birch is the pioneer tree species following fire in black spruce forests, 23' 15 Labrador tea is an abundant shrub in muskegs and moist upland sites throughout the coniferous forests. Regeneration following fire is rapid, 24 16 Subterranean runners of mountain cranberry survive forest fires and facilitate rapid re-establishment, 25 17 Forest fires consumed much of the unincorporated organic matter, leaving mineral soil and rock exposed. Grass and carex species are early colonizers, 26 18 Lichen stands may require more than a century for re-establishment following destruction by fire, 27 19 Arboreal lichens in mature forests may be an important winter food source for barren-ground caribou, 28 20 The lower lichen-bearing limbs of the black spruce tree made more lichens accessible to barren-ground caribou because they droop from the base of attach- ment. Branching in jack pine trees tends to be more vertical, 29 21 Wind and snow dislodge small quantities of arboreal lichens during the winter season (Higginson Lake), 30 22 Soil on upland sites seldom exceeded a few inches in depth, 31 23 Summer soil temperatures in burned-over areas were consistently higher than in unburned areas. Daily and seasonal temperature extremes are believed to be more severe in burned-over areas, 32 ' 24 Decreased soil acidity was found in burned-over areas when compared with unburned areas, 33 ,, 25 Infiltration rate studies did not merit any definite conclusions, but rates 'were not markedly different for unburned or burned-over soils, 34 26 Mineral soil cores for chemical analyses were collected on comparable burned-over and unburned sites, 35 8 ' ) I I FIGURES 9 Figure 1. This was a randomly selected plot, which covered an area of 9.6 square feet in a mature black spruce forest. Note the dense lichen cover. 10 Figure 2. Species occurring in each plot were separated and weighed using gram scales . 11 II I Figure 3. After a training period, forage weights were estimated. Estimates were checked daily. ' 12 Figure 4. Five years after a fire at Marchant Lake there was still no lichen cover. (Compare with Figure 5). 13 Figure 5. Mature black spruce forests at Marchant Lake support a dense layer of bryophytes and lichens. ' 14 , Figure 6. Forest fires destroy organic material and expose bare rock (Father Lake). 15 Figure 7. Several decades will be required before such exposed areas will again support tree growth. 16 Figure 8. Fireweed and bryophytes are some of the early pioneers at Oblate Lake following forest fires (Compare with Figure 9). 17 Figure 9 . Mature black spru e forests at Oblate Lake support a good cover of slow- growing lichens. I 18 l Figure 10. Dense stands of white birch replace black spruce forests following fire (Higginson Lake). 19 Figure 11 . Succession of understory vegetation following fire in jack pine forest was similar to that occurring in burned-over black spruce forests (Newnham Lake). I 20 Figure 12. Dense covers of lichens were present in mature jack pine forests (Black Lake). The lichens, however, were considerably shorter than similar species in black spruce forests . 21 Figure 13 . Thin bark and flammable foliage near the ground make black spruce trees very susceptible to destruction by forest fires. I 22 Figure 14. Sprouting of dormant buds on the enlarged base of the bole was common in fire-destroyed white birch trees . White birch is the pioneer tree species following f ire in black spruce forests. 23 Figure 15. Labrador tea is an abundant shrub in muskegs and moist upland sites throughout the coniferous forests. Regeneration following fire is rapid. 24 Figure 16. Subterr anean runners of mountain cranberry survive forest fires and facilitate r apid r e-establishment. 25 Figure 17. Forest fire consumed much of the unincorporated organic matter leaving mineral soil and rock exposed. Grass and carex species are early colonizers. I 26 Figure 18. Lichen stands may require more than a century for re-establishment follow - ing destruction by fire. 27 Figure 19. Arboreal lichens in mature forests may be an important winter food source for barren-ground caribou. I 28 Figure 20. The lower lichen-bearing limbs of the black spruce tree made more lichens accessible to barren-ground caribou because they droop from the base of attachment. Branching in jack pine trees tends to be more vertical. 29 - ' ; Figure 21. Wind and snow dislodge small quantities of arboreal lichens during the winter season (Higginson Lake). I 30 Figure 22. Soil on upland sites seldom exceeded a few inches in depth . 31 Figure 23. Summer soil temperatures in burned-over areas were consistently higher than in unburned areas . Daily and seasonal temperature extremes are believed to be more severe in burned-over areas. 32 Figure 24 . Decreased soil acidity was found in burned-over areas when compared with unburned areas. 33 Figure 25. Infiltration rate studies did not merit any definite conclusions, but rates were not markedly different for unburned or burned-over soils. I 34 1 I Figure 26. Mineral soil cores for chemical analyses were collected on comparable burned-over and unburned sites. 35 INTRODUCTION The numbers of barren-ground caribou (Rangifer tarandus groenlandicus) in Northern Canada have decreased during recent years. Hoare (1927, p. 35) quoted Seton, whom he recognized as a leading authority on wildlife in Northern Canada, as stating that "Cutting in half the estimates of explorers who went before me, and making a most conservative estimate there are not less than thirty millions..of these caribou letting the wind blow through their whiskers in that northern country." Hoare (1927, p. 39) thought that "It is doubtful if at the present time there are three millions, that is only one-tenth of Seton's 1906 estimate of thirty millions of caribou, Jeft on the mainland in the Northwest Territories." Dr. R. M. Anderson's estimate (Hoare, 1930) agreed with Hoare's. A 1950 estimate based on an aerial census (Banfield, 1954) placed the number at 670,000. A recount during 1955 resulted in an estimate of 277,000 animals, a decline in excess of 50 per cent in 5 years, if the estimates are reliable. Although barren-gr<!)und caribou numbers may have been grossly over- estimated in early years;, there is ample evidence to indicate a recent and dramatic decline in the 'population. Such serious depletion has resulted in hardship and famine atnong Eskimos and Indians who depend on caribou for sustenance. In 1948 the Canadian Wildlife Service of the Department of Northern Affairs and National Resources started a research program to find causes for the depletion. Most of the field staff involved in those investigations (Banfield, 1954; Kelsall, 1957, 1960; Pruitt, 1959b) have commented on the possible importance of forest fires in the ecology of barren-ground caribou. Dr. W. 0. Pruitt (1959b) stated, " ... I believe that the key to the caribou situation lies in an understanding of the carrying capacity of the winter range and especially in appreciating its drastically reduced carrying capacity due to fires." During extensive aerial surveys, it was noted that migrating caribou followed green areas and generally avoided large tracts of burned forest. Destruction by fire of slow-growing lichen forage has been suggesteq. as the reason caribou avoided such areas. The influence of forest fires on barren-ground caribou range in the Northwest Territories was noted earlier by various writers. Pike (1892, p. 47) 36 stated that barren-ground caribou ... seldom come in large quantities to the Mackenzie River, where they used to be particularly numerous in winter. This· is in a great measure accounted for by the fact that great stretches .of the country have been burnt, and so rendered incapable of growing the lichens so dearly beloved by these animals. The same thing applies at Fort Resolution, where within the last decade, the southern shore of the Great Slave Lake has been burnt and one of the best ranges totally destroyed. Dogrib Indians told Harper (1932) that caribou had avoided the lower Taltson River for several years because of forest fires. Irregularities of barren- ground caribou migrations were caused by burned-over sections of land, according to Hornby (1934). Referring to barren-ground caribou, Anderson (1938, p. 400) stated that" ... the destruction of the winter forage of lichens by fire may have been the prime cause of extended movement." Fire has been mentioned also as a contributing factor in declines of caribou and reindeer (Rangifer spp.) in other parts of North America. In Wells Gray Park, British Columbia, the decline of mountain caribou (Rangi- fer tarandus caribou) has been largely attributed to fire (Edwards, 1954). In their study of Alaskan wildlife, Leopold and Darling (1953a, p. 59) com- mented, "To ignore range limitations for caribou is to ignore the crux of the problem. One fire easily could undo the work of decades in protecting a local caribou population from men and wolves." They concluded that fores~tres have eliminated some caribou herds and placed serious restrictions on ot ters. Because the caribou is part of a climax biota, Leopold and Darling (1 753b) believed that accelerated burning influenced the species unfavourably. Fire was considered by Palmer (1926) to be the greatest enemy of reindeer herds in Alaska. In two unpublished reports, Palmer (1940, 1941) described the effects of fire on caribou range in interior Alaska. Darling (1954, 1956), Skoog (1956), and Buckley (1958) have commented on the relationship between fire and caribou in that state also. In Manitoba, barren-ground cari- bou are known to have been deflected by recent burns north of The Pas, which caused them to extend their movements to the southeast. In Ontario, • Quebec, and Labrador the effects of fire on caribou have not gone unnoticed (Hind, 1863; Allen, 1942; Manning, 1946; de Vos, 1948; Rousseau, 1951; Moisan, 1955; Cringan, 1957, 1958; Banfield and Tener, 1958). The problem of providing quantitative and qualitative appraisal of the effects of fire on the winter range of barren-ground caribou was assigned to the writer in July of 1959. The problem was analyzed and separated into the following questions for a preliminary investigation at one important winter range area: * 1. What portion of the winter range in the study area has been burned? 2. What effect has fire had on terrestrial forage and arboreal lichen production? 3. What is the successional pattern of vegetation following forest fire? 4. What is the effect of fire on forest soils? 5. What effect does fire have on barren-ground caribou and other wildlife? 37 DESCRIPTION OF THE STUDY AREA The winter range of barren-ground caribou is restricted largciy to the coniferous forest belt or taiga of Northern Canada. This range, which covers approximately 295,000 square miles, is generally travelled by airplane or boat. Rather than commence an extensive study over such a large expanse, a key wintering range was chosen for intensive study. Presumably, data col- lected on the study area would be generally applicable to much of the winter range, and would lay groundwork for detailed studies on other wintering areas throughout the coniferous forest of Northern Canada. It was considered desirable that the study area be an important or key winter range and that it contain bums of various ages. In addition it was important that the area be as accessible as possible. Location An area in north-central Saskatchewan of approximately 5,000 square miles, extending from 104° to 106° W. longitude and from 59° N. latitude to the Northwest Territories bo11ndary was selected. Sometimes referred to as the world's greatest natura,J! deer pass, this area is one through which barren- ground caribou genera1ly migrate during the early winter and spring and where they sometimes concentrate in large numbers during the winter. Within this area lie·two small communities, Stony Rapids on the Fond- du-Lac River near the 'western border of the study area, and the other, unnamed, on the northwest shore of Black Lake. Their combined population at the present time is 350 people. Of these, approximately 325 are Chipewyan Indians, often referred to as "Caribou-eaters." Stony Rapids is approximately 100 miles east of Uranium City, Sas- katchewan. Air service from Prince Albert or Uranium City to Stony Rapids was available on irregular schedules. The only road in the area, connecting Stony Rapids and the community at Black Lake, is 16 miles long. Transpor- tation to the study sites was provided by charter aircraft. Geology and topography Two broad divisions of topography and geology occur in the study area. The region extending south of a line running from the Fond-du-Lac River east- ward past Black Lake is largely a monotonous, flat, sandstone plain covered with glacial deposits of sorted sand. The sandstone underlying the region is of the Athabaska series of the Proterozoic era· of the late Precambrian. It is composed of rounded to subangular grains of quartz (Blake, 1956). Streams 38 TABLE 1 Weather data from Beaverlodge Lake, Saskatchewan, 1956 January ................ February .............. March .................... April ...................... May ...................... June ...................... July ........................ August .................. September ............ October ................ November ............ December .............. *No report **T =trace i "' = "' ., ~ -11.0 -10.6 5.4 22.2 40.8 57.5 62.2 57.5 41.8 29.6 15.7 -9.9 Temperature (F) § 8 ::s -~ 8 ., ·a 00 a 8 "§ ... .;b E!: » ~ » :a .Q =a =a ., ., "' "' "' 8 ~ = = a ~ "' "' ~ ., " " ~ ~ ~ Ill -3.5 -18.5 15.0 14 -44 0 -21.3 21.3 14 -45 16.4 -5.6 22.0 38 -32 34.3 10.0 24.3 46 -16 52.5 29.1 23.4 77 15 67.2 47.8 19.4 84 34 71.6 52.8 18.8 82 43 66.4 48.6 17.8 84 36 47.9 35.6 12.3 64 26 34.7 24.6 10.1 53 8 22.2 9.2 13.0 42 -18 -3.1 -16.7 13.6 30 -37 flow northward over the sandstone to Black Lake. Snow and rain (inches) = 0 ~ ".;::1 = "' 0 "' .-::: ".;::1 =* ·~ :~ ::s-s ., 8 = '"'"' bOO P.'"' 0 = 8 t;5 ., ... o.,.. .s.r: p. E!: E!: 0 3 = "'"<I" 0 O'tj ·a e<'l ~ = = = 0 .s {/) {/)Q) ~ 11.2 -0 0.42 1.12 10.2 -0 0.30 1.02 3.2 -0 0.10 0.32 2.0 -'F** 0.16 0.20 0 -0.53 0.23 0.53 0 -1.64 0.50 1.64 0 -1.39 0.60 1.39 0 -1.68 0.87 1.68 0.9 -1.49 0.30 1.58 1.4 -1.17 0.35 1.31 6.5 -0.25 0.25 0.90 16.3 -0 0.30 1.63 ---- 51.7 8.15 13.32 North of this line the rock is generally of an early Precambrian assemblage belonging to the Archean era (Fumival, 194la, 1941b). Granite, biotite, andesite, basalt, gneiss, and quartzite are the main components of the rocks. Much folding and faulting have occurred, exposing bedrock and forming outcrop ridges. The topography is comparatively rugged, with many elongated valleys separated by steep hills and ridges. The valleys and ridge!f' are oriented in a northeast -southwest direction. Muskegs, lakes, and streams occupy the valley bottoms. Relief from valley bottom to ridge top varies up to 300 feet. Lakes, generally long and narrow, are numerous throughout the area. Approximately 24 per cent of the area is covered by water. Striations on rocks and water drainage passages indicate that glacial ice moved from a northeast to a southwest direction. Also, the presence of drumlins, eskers, and moraines indicate previous glacial activity. 39 TABLE 2 Weather data from Brochet, Manitoba, 1956 ' Temperature (F) Snow and rain (inches) e e s:: ::l 0 -~ ::l ... '.;:1 s:: -~ Q) ol <d ·~ 00 "' .-::: ol s:: s:: .So e '§ ol -Eh ::lo;S 0 .-::: ... ] 8s:: Q) .So ~ i a i :E '"'"' ooo ""'"' 0 ol Q) Q) s:: e t;S Q) ... "' "' "' "' 5 5 o...., E..t:: p, s:: s:: ii s:: [:!: [:!:0 3 ol ol ol ... ~ -~ ol""" Q) Q) " Q) s 0 0'"0 Q)N ::E ::E ;:E''-, ::E s:: s::s:: ~.S 0 (/) (/)Q) !X: E-< January .......... -15.1 -6.4 -23.8 17.4 6.7 -51.8 7.1 18.2 0 0.35 0.71 February ........ -14.4 -3.0 -25.9 22.9 22.2 -51.4 2.4 19.6 0 0.08 0.24 March ............ -0.6 12.1 -13.3 25.4 37.7 ---41.0 4.9 11.0 0 0.31 0.49 April ................. 17.7 29.1 6.3 22.8 47.8 -19.0 6.7 3.2 0 0.21 0.67 May ················ 33.6 44.4 22.8 21.6 67.2 -1.0 0.2 0 0.49 0.20 0.51 June ................ 54.2 64.1 44.4 19.7 77.9 31.5 T* 0 1.35 0.43 1.35 July ················ 60.7 69.3 52.1 17.2 83.2 37.9 0 0 0.80 0.25 0.80 August ............ 56.2 64.3 48.0 16.3 83.3 37.2 0 0 2.10 0.72 2.10 September ...... 40.4 45.1 35.7 9.4 57.8 25.8 0.5 T* 1.23 0.31 1.28 October .......... 31.5 37.0 26.0 11.0 53.3 8.6 1.8 1.6 0.51 0.13 0.69 November ...... 10.0 19.0 1.1 17.9 39.1 ---43.1 13.2 3.8 0.01 0.60 1.33 December ······ -13.6 ---4.7 -22.6 17.9 34.8 ---48.1 20.7 19.3 T* 0.43 2.07 ------ 57.5 6.49 12.24 *T =trace The soil mantle seldom exceeds a few inches in depth except in areas formerly covered by glacial lakes, where thick soil mantles have resulted from water deposition. Podzol soils, peat bogs, and rock outcrops cover the major portion of the region. Soil pH ranged from 4.0 to 6.8. The lower values were found in the mature forests and the higher ones in recently burned areas. Climate Prior to 1960, weather data had not been collected in the study area. In general, winters are long and cold. Summers are short and moderately warm. The frost-free period extends over approximately 90 days. Precipit.ation is light. : Temperature and precipitation data from two weather stations outside the study area are given in Tables 1 and 2. Beaverlodge Lake is 100 miles 40 west of the study area and Brochet is 120 miles southeast. The climate of the study area is thought to be similar to that of Beaverlodge Lake and Brochet. Climatic extremes probably have more influence ·on food habits and move- ment of barren-ground caribou than the averages shown in the tables would indicate, since snow, temperature, and wind determine to a large extent where and how much winter forage will be available to these animals. Flora The study area is located in a l'>road forest belt generally referred to as the taiga or boreal forest. This belt extends across Canada and has its counter- parts in Alaska and Eurasia. The forest is largely coniferous in character, with deciduous trees occurring in disturbed regions. In order of their abundance, the major tree species are black spruce (Picea mariana), jack pine (Pinus banksiana), white birch (Betula papyrifera), quaking aspen (Populus tremuloides), tamarack (Larix laricina), white spruce (Picea glauca), and balsam poplar (Populus balsamifera). The forest is not utilized as a source of timber except for local require- ments. Jack pine trees are the chief source of lumber for local use. Black spruce, the predominant tree, has little economic value as lumber, but it may be used in the future as a source of pulp and paper. Unfavourable environmental conditions, such as a short growing season and low precipitation, have limited plant variety. A checklist of plants collected in the field is recorded in Appendix A. More detailed collection lists have been published separately (Scotter, 1961a; Thomson and Scotter, 1961). The vascular plant and lichen flora of the study area was relatively unknown before the present investigation. Fauna · A checklist of the fauna encountered in the field is found in Appendix B. Since the bird observations w~e the first recorded in the area, a checklist has been published separately (Scotter, 196lb). Grazing Use The study area was lightly browsed by moose (Alces alces) the year-round, while light to moderate grazing by caribou was evident during the winter and early spring. Human use At the present time trapping, hunting, and fishing are the main occupatiom; of the inhabitants. Several Indian guides are employed at Black Lake during the summer at two fly-in fishing lodges, which cater to sport fishermen. During the winter the Indians hunt and trap. Gold and uranium prospecting have had flurries of activity. Prospectors have used fire as a quick method of exposing bedrock over relatively large areas, and they no doubt have been responsible for some forest fires in the study area. 41 EXTENT AND HISTORY OF FOREST FIRES ,, The relationship between coniferous forest, caribou, and fire is one which existed long before the advent of the white man to the North American continent. The carelessness of both native and white man with fire, however, has been a contributing factor in the increased rate of forest fire destruction apparent over the past decades. History of fire on caribou ranges in North America Evidence that coniferous forests of Northern Canada have been devastated by fires for years can be found in muskegs, where charcoal layers are frequent, and in the forest types themselves. Jack pine, white birch, and quaking aspen forests, all of which can be found in the area, are generally regarded as fire subclimaxes. Journals of early explorers, such as David Thompson, Samuel Hearne, and their modem day counterparts, substantiate the fact that forest fires were prevalent throughout the North. During his third venture in search of copper in 1771-1772, Hearne observed burned areas near the Coppermine and Slave Rivers. Near the Slave River in January 1772, Hearne (Mowat, 1958, p. 132) noted that "During the preceding summer they (Athapuscow Indians) had set fire to the woods, notwithstanding the deep snow, and many months which had elapsed, the fires were still burning in many places .... " He also recorded that Indians departed for new camp sites and left fires unattended. In their journals, covering' a period from 1774 to 1792, Hearne and Tumor (Tyrrell, 1934) mention forest fires frequently. After spending more than 30 summers in northern forests, Bell (1889, p. 52) stated . . . from a very extensive personal knowledge of the conditions of the forests of Northern Canada, I am able to state the fires have become more and more frequent as we approach the present time. . . . The areas of the 'brules' of different dates may be said to be greater in proportion to their recentness. Low (1897) reported that fires in interior Labrador, which occurred annually and often burned throughout the summer, had destroyed one-half of the forested area during the preceding 25 or 30 years. Lutz (1956), in reviewing the history of fire in coniferous forests in Alaska, observed that· most forests showed evidence of fire. Since the late 1890's an estimated 80 per cent of the forest and range lands in Alaska has been burned (Robinson, 1953). The forest-stands along the southern part of the Alaska Highway which did not show modifications by fire werer' rare, according to Raup and Denny (1950). Fire-destroyed forests were recorded by Camsell and Malcolm (1919) 42 in the Mackenzie River basin in the Northwest Territories. Kelsall (1960) calculated that on an important wintering range for barren-ground ,~aribou between Great Bear Lake and Great Slave Lake, 29 per cent of the land area had been burned. Clarke (1940) reported that ·smoke was so thick from fire on the winter range near Yellowknife during July of 1936 that aerial photography was impossible. Devastation by fire has not been limited to forests in Northern Canada and Alaska. According to Femow (1912), of the 5,000,000 acres of forested area in Nova Scotia only 100,000 acres, or 2 per cent, of virgin or semi-virgin timber remained. Fire was largely responsible for this destruction. It may be more than coincidental that about 1912 the last eastern woodland caribou on the mainland of Nova Scotia was reported killed (Anderson, 1938). In the eastern Rocky Mountains of Alberta, Cormack (1953) found disturbances produced by fire a striking and prominent feature of the landscape. According to Anderson (1938), much of this area was formerly within the range of rocky mountain caribou. The role of man in the destruction by fire of northern forests has been thoroughly reviewed by Lutz (1959). The role of lightning in the creation of fires is well known, but its effect on the study area is uncertain. Extent of fire in and near the study area Records of fires in the study area were not kept by the Saskatchewan Depart- ment of Natural Resources prior to 1950. A knowledge of the extent of forest fires was gained through a brief review of literature and by determining the amount of forest of various ages from vegetation maps. In or near the study area, various people noted the presence of bums. In 1796 Thompson (Tyrrell, 1916, p. 137) observed . . . the natives are frequently very careless in putting out fires they make, and a high wind kindles it among pines always ready to catch fire; and bum until stopped by some large swamp or lake; which makes many miles of the country appear very unsightly, and destroys many animals and birds especially the grouse, who do not appear to know how to save themselves, but all this devastation is nothing to the Indian, his country is large. From observations in 1914 and 1920, Harper (1931, p. 28) stated that "Unfortunately a considerable part of the country appears to have been swept time and again, and with disastrous effects, by forest fires, some of which are set purposely by the Indians in order to temporarily improve the hunting." In writing of his experiences as a trapper and prospector in the study arear Munsterhjelm (1953, 1957) made several references to forest fires. Kelsall (1960) reported that of the 16,610 square miles of barren-ground caribou winter range mapped in northern Saskatchewan, only 300 square miles-less than 2 per cent of the area-were unburned. Vegetation cover maps of the study area were prepared in 1960 by Spartan Air Services Limited while under contract with the Canadian Wildlife Service. The maps are to be used primarily as an aid in determining the 43 TABLE 3 Average annual rate of forest destruction by fire expressed in acres per year Per cent Average annual Age of forest Acres of total destruction in acres Recent burns 1-15 years of age (1945-1959) ·································· 311,680 15.4 20,779 Forest 16-30 years of age (1930-1944) ·································· 211,200 10.5 14,080 Forest 31-50 years of age (1910-1929) ·································· 300,800 14.9 15,040 Forest 51-75 years of age (1885-1909) ·································· 357,760 17.7 14,310 Forest 76-120 years of age (1840-1884) ·································· 296,960 14.7 6,599 Forest 120 or more years of age (?-1839) ········································ 540,160 26.8 - Totals .......................................................... 2,018,560 100.0 - carrying capacities of barren-ground caribou winter range. As forest ages were included on the cover maps, they proved useful in determining the acreage of forests in various age classes. Forests and burned areas were classified as 1 to 15 years, 16 to 30 years, 31 to 50 years, 51 to 75 years, 76 to 120 years, or exceeding 120 years of age. The area of each age class was determined by using a dot grid overlay. Total acreage per age class, per cent of total area, and average annual forest destruction by fire in acres, as determined by dividing the acres per age class by the number of years in the age class is shown in Table 3. Water, muskeg, rock, and other miscellan'eous areas, which covered 35.8 per cent of the total area, were excluded from the table. During the period from 1885 to 1944 the rate of fire destruction was almost constant, although it represents an increase of 2.2 times over the period from 1840 to 1884. In the last 15 years, fire destruction has increased 1.4 times over the 1885 to 1944 period and 3.1 times over the 1840 to 1884 period. These increases are coincident with mining activity and white settle- ment. The possibility that some forests may have been burned more than once during the interval· has not been considered. Multiple burning would increase the area of young forests and reduce the area clothed in more mature forests. The recent increased destruction of the boreal forest appears even more disastrous when food habits and habitat preferences of caribou are considered. Caribou prefer a climax habitat, or at least a habitat in the advanced stages of succession, where their principle food species are most abundant. In Northern Canada, the recovery period from vegetation on a bum to climax vegetation is a lengthy process. Short summers, low precipitation, and shallow soil' all combine to slow plant succession. 44 FORAGE UTILIZATION AND TERRESTRIAL FORAGE PRODUCTION One of the most obvious effects of forest fires on the winter range of barren- ground caribou is the reduction of forage. The amount and kind of terrestrial forage available to barren-ground caribou was, therefore, determined in forests at various stages of maturity. Method To determine effects of fire on forage productivity, forests were divided into six age classes extending from 1 to 10 years, 11 to 30 years, 31 to 50 years, 51 to 75 years, 76 to 120 years, and in excess of 120 years. Each class was sampled using the weight-estimate method of forage inventory as suggested by Pechanec and Pickford (1937), and Campbell and Cassady (1955). Forage yield data were obtained from 38 sites distributed among 13 locations. Six of the 38 sites were in jack pine forests. The others were in black spruce forests, or seral stages of white birch which precede the black spruce. Localities from which forage-yield data were collected are Black Lake, Chipman Lake, Dodge Lake, Faraud Lake, Father Lake, Grove Lake, Higginson Lake, Marchant Lake, McKeever Lake, Newnham Lake, Oblate Lake, Offset Lake, and Stony Rapids. Forage yield was sampled by clipping and weighing, or estimating the grams of forage in temporary circular plots. Each circular plot covered 9.6 square feet. Two 100-foot chains, at right angles to each other at the 50-foot mark, were used in establishing co-ordinates to position 16 randomly selected" sample plots. Co-ordinates were established at each ten-foot interval. Samples were stratified so that four plots fell into each quarter of the grid. Five . repetitions, or a total of 80 sample plots, were established in each sampling unit. A sampling unit consisted of a black spruce, jack pine, or white birch forest on an upland site within one of the six age classes. When possible, one repetition within a sampling unit was taken on the north, south, east, and west slopes and the fifth was taken on a level area. The positions of the repetitions were chosen so that they were, as nearly as possible, repre~ sentative of the slope or level area under consideration. Sampling was limited to upland forest stands. Bogs, muskegs, lake shores, drainage channels, and areas with thick peat accumulation were avoided in the sampling process. Repetitions were placed from one-tenth of a mile to 2 miles apart, depending on topography and size of the forest type. Forage was removed from the circular plots and separated into species or groups before being weighed on a spring scale. Yield and floristic composi- 45 tions were recorded. Actual and estimated weights were recorded, on the forms shown in Appendix C, to the nearest 5 grams of green weight. Com- ments on range conditions, utilization, plant vigor, biotic influence, topog- raphy, soil, slope, and other features of interest were included. Weight of the current growth was recorded for forbs, grasses, grass-like plants, and deciduous shrubs. All leaf growth was removed from evergreen shrubs, such as mountain cranberry, (Vaccinium vitis-idaea var. minus) and common Labrador tea (Ledum groenlandicum). Lichen growth was removed to the level where decomposition of the podetia occurs. Decayed portions of podetia have a pungent odor and probably are not preferred by caribou. Bryophytes were not included in forage yield figures since they are probably not eaten by barren-ground caribou except as incidentals with other forage. The above method of forage inventory was well suited to the low- growing ground vegetation. With the exception of two species, common Labrador tea and green alder (Alnus crispa), ground vegetation in mature forests seldom exceeded 6 inches in height. Plants within the study area were distinct and easily recognized as a unit. The method, however, was time consuming. The green weights obtained in the field were converted to air-dry weights. Daily collections of samples were made from each major forage species; then 100 gram samples were stored at room temperature until no fluctuation in weight could be detected. Lichens, in particular, could only be compared on an air-dry basis since moisture content varied from 20 to 85 per cent, depending on weather conditions. Lichens are well known for their hygro- scopic nature. A training period prior to actual field work was held for the purpose of checking estimates against actual weights. Also, field estimates were checked daily throughout: the season. Wide fluctuations in lichen weights made this practice particularly important. ' When large trees were encountered within the sample plot, the plot frame was placed as close as possible to the trunk and sampling continued. Smaller trees were removed, and the plot frame placed over the stumps. Forage utilization Forage-yield data were considered with respect to the barren-ground caribou's winter food habits, which are not well known. Grass and grass-like plants, shrubs, and lichen groups were assigned high, moderate, or low values as caribou winter food, primarily on the basis of information gathered from Loughrey (1952), Banfield (1954), and Kelsall (1957, 1960). This information was supplemented by summer observations of plants which had been grazed during the previous winter, and by limited winter observations. f\ssigned values were determined by plant abundance and utilization by barren-ground caribou and were not based on nutritive content. 1 Various grass and grass-like species appeared to be moderately important winter forage. One of these, horsetail (Equisetum spp.), appeared to be a highly preferred plant (Loughrey, 1952). 46 1 Few forbs, with the exception of those on recently burned areas, were present on the winter range. Forbs as listed in Appendices D and E were considered of low value as forage, as were the liverworts and ferns listed as "other plants". Barren-ground caribou are grazers primarily, and, except for some ever- green species, browse is of limited importance in their winter diet. Only an occasional white birch, or willow (Salix spp.) twig, generally less than 1:yz inches in length and 3/16 of an inch in diameter, was found in rumens of 7 barren-ground caribou. Throughout the summer field season, mountain cranberry shrubs were seen with the leaves stripped from the stem. Stripped shrubs were most abundant near well-established caribou trails. Mountain cranberry may be an important source of protein on the winter range in northern Saskatchewan. Unpublished results from recent experiments on reindeer in Scandinavia indicate that lichen digestibility is increased if eaten along with other vegetation higher in protein. The importance of common Labrador tea is not clear. Kelsall (1960) believed it was actively sought. Common Labrador tea was found in all seven barren-ground caribou rumens analyzed, but since it is a ubiquitous species, it may have been eaten incidentally with more preferred foods. The importance of common Labrador tea, a tall species, may vary with snow depth, the importance being greatest on ranges covered with deep snow. Deciduous shrubs other than willow apparently have limited value as forage. Lichens are regarded generally as the principal winter food of caribou. Nearly 5.0 per cent of the winter diet is composed of lichens according to Kelsall (1960). In the present study fruticose lichens, such as Cladonia alpestris, C. amaurocraea, C. mitis, C. uncia/is, and C. rangiferina, were considered of high value. Field separation of the first 4 lichens listed above was too time consuming to be practical, so they were considered as a group. Lichens of moderate value included both fruticose and foliose species. Of these, Cetraria nivalis has sometimes been regarded as being of high value, but in northern Saskatchewan it was present in only very small amounts.~ Lichens in the low value groups were so classified because of their small size, and hence limited accessibility under winter conditions. Nephroma arcticum was included in this class since it may not be eaten by barren-ground caribou. The shrubs and lichens assigned high, moderate, and low values are listed in Appendices D and E. Some changes in the evaluation may be required as additional food habit data are. obtained from future studies. Forage production Sampling results indicated a close relationship between forest age and forage productivity. Table 4 shows the average production for each age class in black spruce and white birch forests. Average air-dry yield ranged from 290 poUn.ds per acre in the 1 to 10 year class to 942 pounds per acre in the oldest age class. Definite trends in forage production were indicated. Total average productivity was consistently higher with increased age of the tree class. Grass 47 I I I i and grass-like plants and forbs yielded 63 and 122 pounds of forage per acre respectively in the 1 to 10 year age class. Average combined productivity in subsequent age classes never exceeded 14 pounds per acre and it was reduced to 5 pounds per acre in the class older than 120 years. Shrub productivity was low in the first age class, but was reasonably consistent throughout the remaining age classes. Yields of lichens increased consistently from 5 pounds per acre to 482 pounds per acre. More important than the increase in total lichen yield was the increase of high value lichens. Average yield of high value lichens varied from 1 pound per acre in the 1 to 10 year old forest to an average yield of 264 pounds per acre in the class exceeding 120 years of age. Moderate value lichens reached their highest yield during the 51 to 75 year age class, and low value lichens attained dominance in the 11 to 30 year age class. Although there were variations within each age class (Appendix D), lichen abundance was clearly related to maturity of the forest. An older forest sometimes produced less forage than a younger forest of the same age class because of variations in tree density, soil type, and other factors. Forage production in jack pine forests did not show the same consistency as did that of black spruce and white birch forests (Table 5). Two reasons for this inconsistency can be suggested. Because jack pine forest covered only a small percentage of the study area, few samples fell in that forest type. TABLE 4 Average productivity in pounds per acre of air-dry forage by age classes in black spruce and white birch forests Age of forests by age classes 1-10 11-30 31-50 51-75 76-120 120 + Grass and grass-like plants 63 9 4 2 . ································ Herbs ......................... ........................ 122 5 7 9 3 Shrubs High value ··············-······················· 18 234 289 226 356 334 Moderate value ······························ 18 10 8 3 4 6 Low value ........ ····························· 60 159 106 119 110 115 ( 96) (403) (403) (348) (470) (455) Lichens -High value ··················-··················· 1 12 61 66 205 264 Moderate value ······························ 2 16 88 183 125 179 Low value ............. ························ 2 47 44 34 25 39 5) ( 75) (193) (283) (355) (482) Others ·················································· 4 Average pounds of forage per acre ·································· 290 492 604 641 830 942 48 TABLE 5 Average productivity in pounds per acre of air-dry forage in jack pine forests Age of forests in years 5 15 16 35 43 65 Grass and grass-like plants .................................... 21 18 T 0 0 0 Herbs ···················································· 33 66 1 T T 4 Shrubs High value ········································ 24 35 96 309 69 344 Moderate value ................................ 21 4 Low value ········································ 7 139 290 302 187 25 ---- ( 31) (195) (386) (611) (256) (373) Lichens High value ········································ 5 31 55 203 33 Moderate value ································ 2 138 4 9 82 Low value ········································ 60 55 122 65 15 2) (203) ( 86) (181) (277) (130) Others ···················································· T* Average pounds of forage per acre ···································· 87 482 473 792 533 507 *T =Trace Then too, understory vegetation in jack pine forests appeared to be partly determined by soil type. Jack pine forests on sandy soil supported primarily mountain cranberry and a thick carpet of lichens. The same forest on glacial till supported understory vegetation consisting of common Labrador tea, green alder, bryophytes, and lichens which increased the yield of low value forage. Such wide variations related to soil type were not apparent in the spruce forests. The effects of increased forest fire destruction in recent years, considered in the light of yield data, are obvious. Forage available to barren-ground caribou on the winter range is being reduced, both in amount and quality, at the fastest rate within approximately the last 150 years. Average rate of destruction in the recent age class, as determined by dividing the number of years in the recent age class into the total acreage burned during the period was 20,779 acres per year (Table 3). Theoretically the average forage yield on recent bums was 290 pounds per acre or 3,013 tons on the 20,779 acres. A mature black spruce forest, assuming an average production of 942 pounds per acre, would produce 9,787 tons of forage on the same acreage! On the same acreage, the so-called "reindeer lichens" or high value lichens would produce 2,743 tons of forage in the mature forest and only 10 tong' in the 1 to 10 year old age class. In recent bums compared with mature forests, the total yield of forage was reduced more than three times, while high value 49 lichen yield was reduced more than 270 times. When compared with forage yield in mature stands, other age classes also show reduced forage yield, but in smaller proportions. The foregoing data clearly show that fire on barren- ground caribou winter ranges will drastically reduce the quantity of forage and the proportion of high quality plant species. There may have been periods when the boreal forest received extensive fire damage, and intervals of few fires and little damage to barren-ground caribou range. Population levels may have fluctuated accordingly throughout the history of the species. 50 l ARBOREAL LICHEN PRODUCTION North American literature contains casual mention only of caribou or reindeer feeding upon arboreal lichens, yet it is generally agreed that they are an important source of food for these animals. Sir John Richardson was perhaps the first to report use of arboreal lichens by caribou in Canada. Richardson (1829, p. 242-3) stated, "The barren-ground caribou which resort to the coast of the Arctic Sea, in summer, retire in winter to the woods ... where they feed on the usneae, alectoriae, and other lichens, which hang from the trees .... "In Northern Canada, Pike (1892), Tyrrell (1894), Banfield (1954), and Harper (1955) considered arboreal lichens to be constituents of the winter diet of caribou. In Newfoundland, Dugmore (1913) and Ahti (1959) recognized the importance of arboreal lichens during periods when accessi- bility to ground lichen stands was difficult. Referring to caribou, Dugmore (1913, p. 39) wrote . . . during the very heavy falls of snow all ground food is hidden from them, they must then tum to the tree-growing mosses (lichens), such as Sticla pulmonaria, (sic) and the common Usnea or Old Man's Beard, which hangs from the trees in graceful wind-blown festoons as . though arranged especially for. the hunger-driven creatures-a manna in the time of greatest need. Arboreal lichens were assigned varying degrees of importance on winter ranges of caribou on the Gaspe Peninsula (Moisan, 1955), in western Ontario (Cringan, 1957), and in Wells Gray Park, British Columbia (Edwards and Ritcey, 1960). Edwards and Ritcey (1960, p. 5, 7) stated, "In winter the food of caribou is mainly arboreal lichens. . . . These lichens appear to be essential for survival of caribou in winter." Cringan's investigation suggested. that arboreal lichens may be as important a food source as the common terrestrial lichens. Use of arboreal lichens was noted in Alaska by Lutz (1956) and in Labrador by Hustich (1951). Utilization by reindeer was noted by Porsild (1954) in Arctic Canada and by Perez-Llano (1944) in Lapland. Apparently arboreal lichens are important food sources for caribou, particularly as emergency food during periods of deep or ice-crusted snow. Forest fires on the winter range of barren-ground caribou destroy not .. only terrestrial vegetation, but also arboreal lichens. An attempt was made, therefore, to measure the average productivity of arboreal lichens per acre of mature black spruce and jack pine forests in certain parts of the study area. Method Four black spruce and four jack pine trees, each representative of its forest type, were selected at various locations as sample trees. After felling and 51 measuring, the trunks were divided into 1 0-foot sections. Lichens were pain- stakingly removed by hand from the trunk and branches of each section, and the relative abundance of different species noted. The masses of lichens were placed in cotton bags, air-dried at approximately 72 F and weighed. The resulting data on lichen productivity may not be completely accurate because of variable conditions of slope, soil, tree age, exposure, and vegetation cover. However, they provide an idea of the potential food source. In a study of epidendric lichens Edwards et al. (1960) removed the lichens (Alectoria spp.) from two branches at each 10-foot interval of tree height. In the present study, greater accuracy seemed obtainable by removing all lichens from an entire tree that was representative of a particular forest type. An estimate of the number of trees per acre was made at each site by taking five wedge prism readings and measuring the. diameter of all trees viewed in each 360° horizontal sweep. The techniques of sampling were outlined by Kendall and Sayn-Wittgenstein (1959). Of the eight trees from which lichens were removed, all but one were from upland sites. Black spruce sample trees 1, 3, and 4 were 128, 103, and 108 years of age arid 37, 26, and 30 feet tall respectively .. Tree age was determined by counting annual growth rings at a stump height of 6 inches. The location of sample tree 2 represented a black spruce physiographic climax. The soil in that area was water saturated, but it could not be . classified as a muskeg since peat accumulation was not characteristic. The tree was 18 feet tall and 135 years old. Depauperate stands of this kind were encountered on flat areas where drainage was retarded and permafrost was near the surface. The four jack pine sites were characterized by sandy soils and generally little relief.. The ages of the trees were 61, 104, 112, and 101 years, and the heights were 41, 34, 31, and 32'feet respectively. The forests from which these pine tr~es were selected occurred near Black Lake. Those forests have been subjected to frequent fires, and mature stands exist in isolated areas only. Lichen production and availabiHty Arboreal lichens present on the black spruce and the jack pine trees were Alectoria jubata, A. nadvornikiana, A. nidulifera, Cetraria ciliaris, C. sepin- cola, Evernia mesmorpha, Parmelia olivacea, P. saxatilis, P. sulcata, Usnea dasypoga, U. glabrescens, and U. hirta. Of these only the fruticose species of A-lectoria jubata, Evernia mesomorpha, and Usnea hirta were present in sufficient abundance to be important forage for barren-ground caribou. The other lichens on the branches and trunks of these trees would be insignificant as caribou food because of their small size or infrequent occurrence. Tables 6 and 7 show the weights in grams, and per cent of total lichen weight for each section of the individual sample tree. Nearly 50 per cent of the arboreal lichens occurring on spruce trees were within 10 fee( of the ground, compared with only 20 per cent on pine trees. This variation was due to a difference in tree form. Branches were present near the base of spruce 52 TABLE 6 Air-dry weight of arboreal lichens removed from black spruce trees Grams of lichens and per cent of total lichen weight per tree in four height intervals Grams of lichens Tree number per tree 0-10 ft. 10-20 ft. 20-30 ft. 30 +ft. 1 1,011 94 ( 9.3%) 438 (43.3%) 416 (41.2%) 63 (6.2%) 2 477 440 (92.2%) 37 ( 7.8%) -- 3 S66 3S9 (63.4%) 20S (36.2%) 2 ( 0.4%) - 4 434 264 (60.8%) 146 (33.7%) 24 ( S.S%) - "Total 2,488 1,1S7 (46.S%) 826 (33.2%) 442 (17.8%) 63 (2.5%) trees, while pine trunks were almost limbless for the first few feet above ground. The average weights per acre of arboreal lichens occurring in spruce forests and pine forests were calculated as 485 kilograms or 1069 pounds, and 830 kilograms or 1830 pounds (Tables 8 and 9). How~ver, only part of these lichens would be available to the barren-ground caribou. It was arbi- trarily decided that all lichens within 1 0 feet of the ground were within reaching distance of the barren-ground caribou. This may be an excessive height except under conditions of deep and drifted snow. The lower lichen- bearing limbs of the spruce generally made more lichens accessible because they droop low from the bases of attachment. On the lower 1 0-foot section, mature spruce forests provided approximately 275 kilograms or 606 pounds of arboreal lichens per acre, compared with 154 kilograms or 340 pounds of arboreal lichens per acre in mature pine forests. Both species were devoid of lichens on approximately the top 3 feet of growth. The age of this growth interval and its exposure appear to inhibit lichen colonization. From observations over a period of four years, it would appear that • arboreal lichen production as measured in northern Saskatc~wan is near the maximum for the taiga region inhabited by barren-ground caribou. Production TABLE 7 Air-dry weight of arboreal lichens removed from jack pine trees Grams of lichens and per cent of total lichen weight per tree in four height intervals Grams of lichens Tree number per tree 0-10 ft. 10-20 ft. 20-30 ft. 30 +ft. 1 490 98 (20.0%) 288 (S8.8%) 99 (20.2%) OS (1.0%) 2 671 60 ( 8.9%) 37S (SS.9%) 236 (3S.2%) - 3 1,276 323 (2S.3%) 688 (S3.9%) 26S (20.8%) - 4 1,147 218 (19.0%) 701 (61.1%) 228 (19.9%) - Total 3,S84 699 (19.5%) 2,0S2 (S7.3%) 828 (23.1%) OS (0.1%) 53 TABLE 8 Productivity of arboreal lichens per acre of mature black spruce forest (air-dry weight) Grams of Kilograms Grams of Kilograms lichens of lichens lichens of lichens present present per present present per Number of Grams of Kilograms on the acre on the above the acre above Tree trees lichens of lichens 0--10 ft. 0--10 ft. 10ft. the 10ft. number per acre per tree per acre section section section section 1 521 1,011 527 94 49 917 478 2 1,200 477 572 440 528 37 44 3 635 566 359 359 228 207 131 4 1,111 434 482 264 293 170 189 Total ...................................... 1,940 1,098 842 Average weight of lichens per acre in kilograms ................ 485 275 210 Average weight in lichens per acre in pounds ............ , ......... 1,069 606 463 in the Gordon Lake and Taltson River regions of the Northwest Territories and in northwestern Manitoba appeared to be greatly reduced. Edwards et al. (1960) suggested that more of the total lichen load was accessible periodically because of the lichens present on fallen trees and those dislodged by wind or snow. This additional availability was demonstrated at Offset Lab in the study; area. During the winter, either the weight of snow or a strong wind had broken off a 140-year-old spruce and the foliage was still green in June. Lichens from this tree had been so meticulously removed by barren-ground caribou during their northern migration that even fragments were difficult to find. Arboreal lichens from the nearest erect tree of similar age and height weighed 4 77 grams. The importance of fallen trees in making formerly out-of-reach lichens accessible to barren-ground caribou appears rather limited. Assuming a theoretical mortality rate of 1 per cent per year of trees in forest stands, an additional .44 to 8.72 kilograms, or 1 to 19 pounds, of arboreal lichens would be made available per acre per year. This is a small contribution to th.e food supply and may be of little importance except under the most critical conditions. In Northern Scandinavia and Finland, Hustich (1951) reported that reindeer herders cut lichen-covered trees to make emergency food available for their animals. Trappers in the Iosegun Lake area of Alberta Nave cut down conifers so that mule deer ( Odocoileus hemionus) could feed on the arboreal lichens during periods of deep snow. 54 Wind and snow dislodge small quantities of lichens during the winter season. The importance of fallen lichens to barren-ground caribou is unknown, although the yield may exceed that from fallen trees. The accumulated arboreal lichen production exceeded one-half ton per acre in mature spruce, and approached 1 ton per acre in mature pine stands. The situation is reversed when availability is considered. Amounts of lichens within the animals' reach on standing trees, those on fallen trees, and those dislodged were roughly approximated at 285 kilograms or 628 pounds . per acre for mature spruce and 170 kilograms or 375 pounds per acre for mature pine. However, barren-ground caribou may not be able to remove all the available arboreal lichens which are woven among the needles. Lichens "stockpile" their growth from year to year, so these data represent cumulative weights rather than annual production. Lichen utilization The growth form of the trees made it difficult to determine the degree of lichen utilization because of varying lichen densities within and beyond the reach of caribou. Caribou utilization may have accounted for the relatively small amount of lichens present on the lower 10 feet of black spruce sample tree 1. Several trappers familiar with wintering conditions in the area were questioned about the use of arboreal lichens by barren-ground caribou. With- out exception they had observed animals eating lichens and believed them to TABLE 9 Productivity of arboreal lichens per acre of mature jack pine forest (air-dry weight) Grams of Kilograms Grams of lichens of lichens lichens present present per present Number of Grams of Kilograms on the acre on the above the Tree trees lichens of lichens 0-10 ft. 0-10 ft. 10ft. number per acre per tree per acre section section section 1 442 490 217 98 44 392 2 1,351 671 906 60 81 611 3 915 1,276 1,168 323 296 953 4 897 1,147 1,029 218 196 929 Total ...................................... 3,320 617 Average weight of lichens per acre in kilograms .................. 830 154 Average weight of lichens per acre in pounds ...................... 1,830 340 Kilograms of lichens present per acre above the 10ft. section 173 825 872 833 2,703 676 1,490 55 be important in the winter diet. According to information received by Hustich (1951) from the Indians at Fort George, Quebec, Evernia mesomorpha was well-liked by caribou during the winter. Rumen samples from seven barren-ground caribou were analyzed in an attempt to establish the relative importance of arboreal lichens. Two samples showed traces of arboreal lichens. As the animals were taken in early winter, the results may not represent the food habits under more critical conditions. Also, lichens are fragile and may be subject to rapid digestion. Work by Norris (1943) indicated that rumen contents are an inaccurate measure of the forage eaten. Under critical conditions, and perhaps throughout the winter, arboreal lichens may contribute substantially to the diet of barren-ground caribou. The availability of these lichens is an important measure of their potential significance when compared with terrestrial food plants. Investigations by Pruitt (1959a, p. 177) indicated that "Caribou appear to have a threshold of sensitivity to the hardness, density, and thickness of the snow cover." As the threshold of sensitivity is exceeded caribou may no longer be able to obtain the required amount of food from terrestrial plants. Arboreal lichens may be increasingly important as that threshold is approached. Lichen ecology Arboreal lichen abundance apparently depends on tree age, density, species, and moisture conditions. With trees of similar age, there appeared to be an inverse relationship between tree density and lichen productivity per tree. Lichen productivity per tree increased with reduced tree density. Since lichen growth is cumulative it was expected that productivity would vary roughly with age. The youngest jack pine produced the smallest amount of lichens in its group (Table 7) and the oldest spruce and pine, excluding the depauperate specimen, produced the largest amount of lichens in their respective groups (Tables 6 and 7). Although data and observations were limited, it appeared that the more mesic spruce sites were more productive than the upland sites. The mesic sites seemed to favour the growth of Alectoria jubata over Evernia mesomorpha and U snea hirta. There were variations in the species distribution of lichens on the two tree types. Alectoria jubata was the most abundant lichen on both spruce and pine. Evernia mesomorpha and Usnea hirta were more abundant on pine than on spruce and also more abundant on the lower than the upper tree sections. Usnea hirta would probably be the least important, and Alectoria jubata the most important of the three lichens because of its relative abund- ance and accessibility. Arboreal lichens are apparently important sources of foragy during critical periods and perhaps throughout the entire winter season. Destruction of these extremely slow-growing plants by fire must be considered a .,serious loss of winter caribou food. ' ' 56 PLANT SUCCESSION FOLLOWING FOREST FIRES Plant succession following forest fires is dependent on several factors including site potential, size of the burned area, intensity of the fire, climate for several years following the bum, seral stage of vegetation at the time of the bum, and seed available for dispersal. The influence of these factors on the cycle of recovery is often difficult to detennine. Method The seral stages, for descriptive purposes, were grouped in three major divisions or stages of succession. The description of the liverworts and mosses, lichens, tree species, and other vascular plants within those three stages were based on observations made throughout the study. Bryophytes Lower foi:ms of plant life, such as bryophytes, are rapid colonizers in the first successional stage. The liverwort, Marchantia polymorpha, and the mosses Polytrichum juniperinum, P. piliferum, and Ceratodon purpureus, were the first post-fire plants to appear. Marchantia polymorpha appeared to be a temporary species. Profuse growth of this species occurred only in shaded spots or in moist depressions. About 5 years after a fire, this liverwort was present only in moist depressions or as impoverished individuals scattered at the bases of various mosses. Spores of Marchantia polymorpha may be wind disseminated over large areas since" plants were not found in the periphery of mature forests encompassing recent bums. Polytrichum juniperinum, P. piliferum, and Ceratodon purpureus, which displace Marchantia polymorpha, have greater longevity than the liverwort, although abundance of the first two mosses listed decreased 10 to 15 years after fire. Ceratodon purpureus was a characteristic member of both the first aJ!d second stage of development. Polytrichum juniperinum and Ceratodon purpureus were found in drier habitats. Polytrichum piliferum was most abundant in moist habitats. The first years following forest fires are evidently the most advantageous period for growth of those mosses. The second stage of bryophyte succession was generally dominated by Aulacomnium palustre, Ceratodon purpureus, Hedwigia ciliata, Pleurozium schreberi, and Polytrichum commune. Those bryophytes play an important role in the accumulation of litter on exposed mineral soils and rocks which supported plant growth previously. 57 TABLE 10 Dominant bryophytes present in three successional stages following forest fires First stage (1 to 10 years) Ceratodon purpureus Polytrichum juniperinum Polytrichum juniperinum var. alpestre Second stage (11 to 50 years) Aulacomnium palustre Ceratodon purpureus Hedwigia ciliata Third stage (51 or more years) Dicranum elongatum Dicranum rugosum Hylocomium splendens Pleurozium schreberi Polytrichum commune Polytrichum piliferum Marchantia polymorpha Pleurozium schreberi Polytrichum commune Ptilium crista-castrensis · Sphagnum capillaceum Sphagnum capillaceum var. tenellum Ptilidium ciliare Dicranum elongatum, D. rugosum, Hylocomium splendens, Pleurozium schreberi, Polytrichum commune, Ptilium crista-castrensis, Sphagnum spp., and the liverwort: Ptilidium ciliare, were constituents of an almost continuous bryophyte carpet in mature spruce stands. Whether or not such dense stands of bryophytes have a thinning effect on important caribou food lichens, such as Cladonia alpestris and C. rangiferina, was not determined. The more abundant bryophytes present in the three successional stages are listed in Table 10. Lichens When fires occur, destruction of fire-susceptible lichens is generally complete except for patches in md,ist sites. Rate of lichen recovery depends on the extent of destruction, but it is a very slow process. Lichens are perennials, which are characterized by slow growth and a long life span. Fire appeared to be more destructive to lichens than to other plants because of the much slower growth rate of the lichens. Crustose lichens, such as Lecidea cuprea, L. granulosa, and Baeomyces rufus, comprise the earliest stages of succession. Peltigera canina var. spuria is generally the first foliose lichen to appear. Displacement of Marchantia polymorpha and Polytrichum spp. by Peltigera canina var. spuria starts gradu- ally about 5 years-after a fire. Cup lichens belonging to the genus Cladonia, such as Cladonia coccifera, C. deformis, and C. pyxidata, are present occasionally late in the first succes- sional stage, -but are more characteristic of the second. Other -lichens which reached their best development in the second stage of succession are 'listed in Table 11. The lichens in that stage are eaten by barren-ground caribou, but are of little significance since they are generally small in size and do n6t form clumps. Exceptions are Cladonia amaurocraea, C. mitis, Peltigera canina, and Stereocaulon spp. which are important forage lichens. 58 TABLE 11 Dominant lichens present in three successional stages following forest fires Crustose Baeomyces rufus Lecidea cuprea Foliose First stage (1 to 10 years) Lecidea granulosa Peltigera clltlina var. spuria Crustose Baeomyces rufus Lecidea cuprea Foliose Peltigera canina Second stage (11 to 50 years) Lecidea granulosa Ochrolechia frigida Peltigera canina var. spuria Peltigera canina var. rufescens Fruticose Foliose Cetraria crispq Cetraria nivalis Cladonia alpicola Cladonia amaurocraea Cladonia bacillaris Cladonia botrytes Cladonia carneola Cladonia cocci/era Peltigera aphthosa Peltigera canina Fruticose Foliose Cetraria crispa Cladonia alpestris Cladonia amaurocraea Cladonia gracilis Cladonia mitis Cladonia multiformis Nephroma arcticum Peltigera aphthosa Peltigera canina Fruticose Cladonia alpestris Cladonia mitis Cladonia cornuta Cladonia cristatella Cladonia deformis Cladonia gracilis Cladonia mitis Cladonia pyxidata Cladonia pyxidata var. neglecta Cladonia verticillata Third stage First pha~ (51 to 120 years) Cladonia rangiferina Cladonia turgida Cladonia uncialis Stereocaulon alpinum Stereocaulon tomentosum Second phase (120 or more years) Peltigera canina var. ulorrhiza Peltigera malacea Peltigera pulverulenta Cladonia rangiferina 59 In the third stage of succession, two phases were clearly recognized. Large numbers of diverse lichen species were present in the first phase. In the second phase Peltigera spp. and "reindeer lichens", such as Cladonia alpestris and C. rangiferina, which are preferred food species, were most abundant in the lichen flora. "Reindeer lichens" reach their best development in the second phase of the third stage. These important food sources are particularly vulnerable to destruction by forest fires. Recovery is slow because of the low rate of growth, and because of unfavourable ecological conditions. It has been estimated that recovery requires 30 years (Manning, 1946), 30 to 40 years (Sarvas, 1937), 30 to 40 years (Itkonen, 1948). Palmer (1940, p. 2) believed that "A burned-over lichen range may require as much as 40 or more years for recovery." In northern Saskatchewan it woUld appear that complete recovery of two "reindeer lichens", ( Cladonia alpestris and C. rangiferina), to their former abundance may take from 90 to 120 years. In fact, fire appeared to have been as destructive to important food lichens as to the forest itself. In black spruce forests it was unusual to find Cladonia alpestris and C. rangiferina in areas burned within 30 years, except for small relic areas which had escaped fire. Lichen recovery in jack pine forests appeared to be some- what more rapid. Succession in jack pine forests was similar to that described in black spruce forests. However, bryophyte carpets appeared to be considerably reduced in mature stands. Peltigera spp. and Cladonia rangiferina were seldom encountered. Other lichens were much more abundant, but their height seemed considerably restricted when compared with the lichens of black spruce forests. Annual growth rates. of "reindeer lichens" have been of great interest for several years. After cons!derable research Russian scientists have developed an acceptable procedure for lichen growth rate research (Andreev, 1954). In studying fruticos~ species of Cladonia, the Russians recognize three periods of growth (Andreev, 1954). During the first interval, which is called the growth period, length of the podetium or stalk increases continuously for a number of years. Branching occurs at the top of the podetium so each joint is 1 year younger than the joint below, or in other words, the age of joints increase as they near the base of the podetium. The intervals between lateral branches on the main stalk, called joints, also increase in length during the period of growth. Annual.lichen growth comprises the increase in length of the joints as well as the addition of a new joint. In the second period of growth, which is referred to as the period of renewal, the base of a podetium decomposes at approximately the same rate as the top of the podetium is growing. The period of renewal is followed by a period of degeneration. During this period the rate of decomposition at the base of podetia exceeds' the rate of addition at the top. Finally podetia perish. The period of growth or formation of podetia may last for 25 ye~s, but a 1 0-year growth period is average. The renewal period may extend over several decades, but the period of degeneration is similar to the period of 60 growth. The lifespan for Cladonia alpestris and C. rangiferina appears to be lengthy in northern Saskatchewan. At Dodge Lake, where forests were approximately 170 years old, Cladonia alpestris and C. rangiferina with com- pletely decomposed podetia could not be found. In northern Saskatchewan lichens which showed decay along the whole length of the podetia were noted only in muskegs that had escaped fire for a long period of time. Russian scientists, working on management problems on reindeer ranges, have accepted as fact that podetia of Cladonia branch but once a year. They have suggested that the growth rate is equal to the height of the living portion of the podetium, under moist conditions, divided by the number of joints on the podetium. The measurements are taken under moist conditions because the plant is extremely fragile and because it shrinks when dry. The following formula was used in measuring 48 podetia of Cladonia alpestris and 48 podetia of C. rangiferina at each of four locations in northern Saskatchewan: Height of the living podetium = Average annual linear growth Number of joints on the living podetium rate of the podetium Separation of living portions of the podetia from decaying portions was possible because a colour change occurs when decay is initiated. The colour change was more distinct in Cladonia rangiferina than in C. alpestris. Of the two Cladonia species studied, C. rangifetina had a faster growth rate than C. alpestris. However, Cladonia rangiferina had fewer years of growth before reaching the period of renewal (Table 12). TABLE 12 Annual linear growth rates of Cladonia alpestris and C. rangiferina at four locations in black spruce forests of northern Saskatchewan. Annual average Growth rate Length of Location growth rate extremes growth period Cladonia alpestris Dodge Lake ...................................... . 4.3 mm. 3.6-4.9 mm. 10-14 yrs. McKeever Lake ............................... . 4.7 mm. 3.2-6.1 mm. 8-14 yrs. Newnham Lake ................................. . 3.4 mm. 3.0--4.2 mm. 8-13 yrs. Chipman Lake ................................ . 3.9 mm. 3.1-5.1 mm. 8-12 yrs. Average and range ................... . 4.1 mm. 3.0-6.1 mm. 8-14 yrs. Cladonia rangiferina Dodge Lake ....................................... . 4.8 mm. 3.0-6.7 mm. 6-12 yrs. McKeever Lake ............................... . 5.7 mm. 4.1-7.3 mm. 6-9 yrs. Newnham Lake ................................. . 4.7 mm. 3.4-5.6 mm. 7-11 yrs. Chipman Lake ................................... . 4.4 mm. 3.0-5.5 mm. 6-12 yrs. Average and range ................... . 4.9 mm. 3.0-6.7 mm. 6-12 yrs. .. Growth rates of lichens in northern Saskatchewan, Russia (Andreev, 1954), and Newfoundland (Ahti, 1957), seem to be fairly similar. The growth rate of Cladonia rangiferina in Newfoundland was similar to that in 61 northern Saskatchewan, but less than that in Russia. The growth rate of Cladonia alpestris in Newfoundland was greater than ·in northern Saskatche- wan or Northern Russia (Table 13). Habitats from which these data were assembled vary widely. Growth of Cladonia alpestris in Newfoundland. may be favoured by the oceanic climate. TABLE 13 Annual linear growth of Cladonia as reported by various workers. Annual growth rate in rom. Worker Place C. alpestris C. rangiferina Scotter N. Saskatchewan 4.1 4.9 Ahti Newfoundland 6 to 7 4.8 Andreev Russia (sub-tundra forest) 4.4 5.9 Vascular Plants After a fire, the successional pattern of grass, grass-like plants, herbs, and shrubs depended largely on the seeding and sprouting habits of the species involved. Hardy and prolific invaders after fire were fireweed (Epilobium angustifolium), pale corydalis (Corydalis sempervirens), sedges ( Carex aenea, C. deflexa, C. canescens), bluejoint (Calamagrostis canadensis), hairgrass (Agrostis scabra), woodland horsetail, and willows. Fire removed thick mantles of litter from seedbeds and made such· invasions successful.· Fireweed colonized new bums rapidly and contributed from 25 to 60 per cent of the total forage production on recent bums. However, this ubiquitous herb was abundant for only a short period of time. Fireweed disappeared, except for ;;scattered individuals, presumably because of the increased competition for: sunlight. Only a few other herbs were generally present. Pale corydalis plants, although few in number, were always present. In contrast, willow herb (Epilobium glandulosum) was present in only one bum and then in consider- able abundance. Typical grass and grass-like invaders reached their maximum abundance about 5 years after a fire. Bluejoint was occasionally present in mature forest stands, but the plants were generally sterile. Moist depressions were occupied by woodland horsetail stands of varying densities. Two common sedges present on recent bums were Carex aenea and C. deflexa, although C. brunnescens, C. canescens and C. foenea were occasionally present in this seral stage. Raspberries (Rubus idaeus var. aculeatissimus) were seldom present in burns older than 20 years of age. Invasion of this plant is so rapid following a fire that seed must lie dormant in the soil for years waiting for fire to reduce competition and make conditions favourable for germination. The seeds appear too large for wind dissemination and the plant is sometimes· so abundant that animal or bird dissemination seems improbable. Following fires, plants such as fireweed, bluejoint, and sedges rexfew the humus layer which favours lichen growth. Important forage lichens, however, are unable to compete successfully with these plants. 62 Wind is an important agent in the seed dissemination of postfire species. Airborne seeds of fireweed, which bloomed from late June to September, are dispersed by the wind over large areas. Some sedge and grass species repro- duce by rhizomes and through seed dissemination by wind, birds; and mammals. Uqdestroyed riparian vegetation within burned areas, and peri- pheral vegetation bordering burned areas, are potential seed sources. Mountain cranberry, which has a wide ecological amplitude, was one of the most abundant shrubs in black spruce forests 1 0 years after a fire. Its density was equaled by common Labrador tea in some regions. As the forests neared maturity common Labrador tea decreased in abundance, while moun- tain cranberry remained the same or decreased slightly. Subterranean runners of mountain cranberry survived forest fires and were the organs responsible for re-establishment of this shrub. Dense carpets of the low-growing shrub were formed. Common Labrador tea was an abundant shrub in muskegs and the more moist upland sites throughout the coniferous forests. Leaf cover was not as dense, the plant was not as numerous, and total forage weight was not as great as that of mountain cranberry. Because of its· height, however, common Labrador tea sometimes dominated the aspect. In mature forest the yield of common Labrador tea was reduced because this plant is intolerant of shade. Generally, grass, grass-like plants, and herbs were encountered infre- quently in second and third stages of succession, not only for reasons of shade intolerance, but also because of competition from bryophytes and shrubs. Of the species present, bunchberry ( Cornus canadensis) and northern comandra (Geocaulon lividum) were the most abundant. Willows, raspberries, skunk currant (Ribes glandulosum), and pin cherry (Prunus pensylvanica) occurred in an early seral stage. Various willows occurred in most of the more recent bums. Long-beaked willow (Salix bebbiana) was characteristic of drier upland sites, while grayleaf willow (S. glauca) and flat-leaved willow (S. planifolia) were more common on moist upland sites. In the study area willow was sparse and only light regeneration following fire was noted. Even as members of riparian vegetation, willows· were not abundant. Berry-producing shrubs composed the majority of shrub vegetation in the second stage of succession. Many of these species are reproduced vege- tatively and many of the underground parts escape destruction by fire. F1eshy fruits of some shmbs survive fire, and the viability of certain shrubs' seeds may be increased by heat from fire. Black crowberry (Empetrum nigrum var. hermaphroditum) was restricted to mature forest sites and its occurrenee .. was sporadic. Small cranberry (Vaccinium oxycoccus), bog bilberry (V. uliginosum), northern Labrador tea (Ledum palustre var. decumbens), and cloudberry (Rubus chamaemorus) were occasionally present. One shrub, green alder, was present in all stages of succession in both jack pine and black spruce forests. The shrub produces a voluminous quantity of leaves which appear to be resistant to decay. The leaf accumulation suppressed other plant growth directly under the shrub. Table 14 lists the plants generally present in the three stages of black spruce forest succession. 63 I TABLE 14 Dominant vascular plants in three successional stages following fire in black spruce fQrests Agrostis scabra Calamagrostis canadensis Carexaenea Carex canescens Carex deflexa Corydalis sempervirens Epilobium angustifolium Epilobium glandulosum First stage ( 1 to 10 years) Equisetum sylvaticum Poaglauca Prunus pensylvanica Ribes glandulosum Rubus idaeus var. aculeatissimus Salix spp. Second stage ( 11 to 30 years) Alnus crispa Arctostaphylos uva-ursi Comus canadensis Geocaulon lividum Juniperus communis Ledum groenlandicum Alnus crispa Comus canadensis Empetrum nigrum Geocaulon lividum Ledum groenlandicum Lycopodium annotinum Lycopodium complanatum Lycopodium obscurum Ribes oxyacanthoides Salix spp. V accinium uliginosum Vaccinium vitis-idaea var. minus Final stage (30 or more years) Ledum palustre var. decumbens Rubus chamaemorus Salix bebbiana V accinium oxycoccus Vacc;inium vitis-idaea var. minus Succession of tree species Three species, black spruce, jack pine, anp white birch, were the most abundant trees on the study area. On one frequently burned area aspen had • gained a foothold. Tamarack was common in muskegs, and balsam poplar was present along some sandy lake shores. White spruce may be the ultimate climax species in view of its presence on some areas prot~cted from fire. Jack.pine. Forest fires are essential in the maintenance and perpetuation of jack pine in the study area. Jack pine forests occur commonly in nearly pure stands following fire and are good indicators of sandy soil. Fire appears to prepare an excellent seed bed for the jack pine. Fire eliminates competitors for nutrients, light, and moisture. Also, ashes from fires may increase the., amount of nutrients available. Because of extensive and repeated fires, the southern region of the area supported subclimax stands of jack pine. The serotinous cones of this species resist destruction by fire and at the same time the heat of the fire aids in opening the cones and in releasing their seeds. The early age at which jack pine bears cones, together with the fire resistance of the cones, enables it to spread rapidly in fire-disturbed regions of the study area. Cones were noted on jack pine trees which were only 7 years old. 64 Jack pine forests are intolerant of shade and as the stands mature black spruce intrudes to make an admixture. The latter species gradually becomes the dominant. Jack pine forests resist fire better than black spruce forests. Fire-scarred jack pine trees were encountered frequently, while black spruce trees apparently succumb even to low-intensity fires. White birch. Fire in black spruce stands favours the invasion of white birch as the pioneer tree species. Leaves from these shade-intolerant hardwood trees contribute substantially to the renewal of litter on the forest floor. Improved litter conditions aid in the re-establishment of an understory of lichens. Following forest fires in the study area, exposed mineral soil provided suitable areas for white birch regeneration. On some bums young trees reached such densities that they impeded walking. White birch is easily killed by fire, partly because its bark is flammable. Sprouting of dormant buds on the enlarged base of the bole was common in fire-destroyed white birch forests, but such sprouting was insignificant in the rapid invasion of white birch in former black spruce forests. The dense stands of young white birch were established as a result of wind-disseminated seeds: Mineral soil and exposure of seeds to sunlight aided white birch regeneration. The comparatively short-lived white birch trees dominated for 50 to 75 years and were then overtopped, suppressed, ana eliminated by black spruce. White-birch forest boundaries were very distinct and clearly marked peripheries of bums. Black spruce. Thin bark and flammable foliage near the ground make black spruce trees very susceptible to destruction by forest fires. Tinder-dry ground lichens and arboreal lichens, along with hot, dry summer weather add to the fire hazard. Few black spruce, outside of muskegs, escape destruction during a forest fire. Black spruce are able to grow on wet, peaty soils as well as on drier upland sites. Most black-spruce muskeg forests contain a sprinkling of tamarack, and an occasional white birch is present in upland sites. The nearly pure stands of black spruce on rock outcrop formations were shallow- rooted and often were found growing in litter cover rather than in mineral soil. Black spruce seeds remain viable after maturity, not unlike those of jack pine trees. Undoubtedly, this is important in perpetuation of the species. The cones, which are serotinous and persistent, are situated near the tree tops where they are less likely to be destroyed by fire. Seeds are dispersed later onto exposed surfaces where reduced vegetative competition and other favour- able conditions for reproduction are met. Black spruce seedlings are over- topped by white birch or jack pine, and then make a gradual entry into the forest canopy until they gain dominance. Black spruce, a small and slow- growing but moderately long-lived species, propagates by layering as well as by seed. This results in uneven-aged stands. Black spruce trees, sirrl'ilar to jack pine trees, produce seed cones at an early age. Seed cones were found on 15-year-old trees. 65 As the age of black spruce stands increased, there was a decrease in the number of lichen species present, although lichens, such as Cladonia alpestris and C. rangtferina, increased. The latter are important sources of forage for barren-ground caribou. Plants in the upland black spruce sites exhibited a low degree of diversity. A ground cover of bryophytes was concomitant with mature black spruce forests. Whether or not black spruce can be considered a member of the climax forest on upland sites is difficult to determine. It is capable of self-perpetua- tion and has a high degree of stability. White spruce, however, may be the ultimate climax if given protection from fires for a lengthy period of time. A relic area at Faraud Lake, which is isolated by two small streams, supported . white spruce. That suggested the surrounding area may have been forested with white spruce. f 66 EFFECTS OF FOREST FIRES ON SOIL PROPERTIES Previous studies show that the effects of fire on soil properties vary widely with soil type, climate, vegetation, and severity of the bum. Few definite conclusions could be reached from the literature. An investigation by Lutz in Alaska is the only known study in North America made at a comparable latitude and in similar forest types. From his study Lutz (1956, p. 78) concluded, in part, "No possible justification for uncontrolled wildfires can be found in the realm of soil science. Such fires can n~ver be justified or even excused on the basis of beneficial effects on the soil, despite the fact that fires may have favorable effects on certain properties." In this investigation influences of fire on forest soils have been divided into effects on physical properties of soil, on chemical properties of soil, and on unincorporated organic matter. Data on edaphic changes wrought by forest fires are important considerations in understanding the ecology of lichens and other plant life which reclothe the devastated area. Description of sample sites Sample sites were selected in mature black spruce forests, mature jack pine forests, and on burned-over sites which formerly supported those forests. Mature-forest sample sites were chosen as comparable as possible to adjacent burned-over sites in slope, topography, drainage, and soil parent material. For example, at Marchant Lake soil properties under a 155-year-old black spruce forest were compared with an adjacent 5-year-old bum. Soils supporting a· 130-year-old black spruce forest stand were compared with those on a bum approximately 13 years of age at Dodge Lake. Ages of the two bums at Newnham Lake were 5 and approximately 22 years. Those areas had been covered with jack pine forests and were compared with a mature jack pine and black spruce forest with similar conditions of slope, topography, and drainage. Soil under the burned-over areas was medium sand of a pale brown colour, compared with grayish coloured, medium loamy sand under the jack pine and black spruce forest. Soil in the northern section of the study area was shallow, seldom exceeding a few inches in depth on upland sites. At Newnham Lake, sandy soil, which resulted from water deposition, exceeded four feet in depth. Soil horizons were indistinct. Since pedologists have not worked in the region, soil classification and description will be limited to colour and texture as given in Table 15. Records of texture of the soil, determined by feel, and colour of the soil, determined 67 with a Munsell soil-colour chart, were made in co-operation with the Soil Survey Research Branch of the Canada Department of Agriculture at Edmon- ton, Alberta. Methods Data on physical and chemical soil properties were obtained from the same sample sites. Sampling procedures were not random since boulders and thin soil mantles sometimes precluded random sampling. However, six sample sites were distributed as well as possible on each area. Physical properties. Information was obtained on soil temperature, water infiltration rate, and soil erosion. To determine soil temperature, six readings were taken during August between the hours of 10:30 a.m. and 1:00 p.m., using a Weston soil thermometer at depths of 1 and 3 inches. Notes on erosion were made from observations on the ground and while flying at low altitude in airplanes. TABLE 15 Descriptioq of soil colour and texture at sample sites Site Munsell Colour Description Texture 5-year-old burn at Marchant Lake .. . . .. .. .. .. .. . . ... . ... . .... .... Brown Coarse sandy loam Mature black spruce forest at Marchant Lake . . . . . . . . . . . . .. . . Brown Coarse sandy clay loam 13-year-old burn at Dodge Lake .................................. ·.. .. Light yellow-brown Medium sandy loam Mature black spruce , forest at Dodge Lake ................ :.... Pale brown Medium sandy loam 5-year-old burn at , Newnham Lake .............................. Pale brown Medium sand 22-year-old burn at Newnham Lake .............................. Pale brown Medium sand Mature jack pine and black spruce forest at Newnham Lake .. Gray Medium loamy sand Methods used by Bums (1952) and Beaton (1959) were employed to determine water infiltration rates. A steel cylinder 20 centimeters high, with a cross-sectional area of 100 square centimeters, was .driven 10 centimeters into mineral soil. After the unincorporated organic matter inside the cylinder was removed, muslin was placed over the soil to prevent disturbance of soil particles. The time required for one liter of water to pass into the soil was observed to the nearest 15 seconds. Replications at two different locations in the burned-over and mature forest areas were made at Dodge Lake. Chemical properties. Eighteen soil cores, 3 from each of 6 sites, were collected from the 0-to-3 inch depth of mineral soil for chemical adalyses. Changes in chemical composition of soils attributable to fire have seldom been detected below the upper soil layers, and for this reason sampling was 68 limited to the 0-to-3 inch depth. Plastic bags were used for storing the air- dried soil. The Soil Survey Research Branch of the Canada Department of Agriculture in co-operation with the Research Council of Alberta made chemical analyses and laboratory pH determinations on the mineral soil cores. Extractions were as outlined by the Association of Official Agricultural Chemists (1955). Calcium, magnesium, sodium, and potassium were deter- mined using the Beckman DU flame spectrophotometer with a model 9200 flame attachment and line-operated power supply unit as outlined by Baker (1956). The modifications suggested by Mathieu and Burtch (1961), Mathieu and Carson (1961), and Carson et al. (1962) were incorporated. A cleaning solution as proposed by Choiniere (1956) was used. Total nitrogen was determined with the Kjeldahl method of Prince (1945), using mercury as a catalyst. Available phosphorus was measured by extracting 5 grams of soil with 25 mi. of 0.03 normal sulfuric acid and 0.03 normal ammonium fluoride. Available phosphorus was determined calorimetrically by using a Fisher Model No. A electrophotometer. Composite soil samples, taken from the first 3 inches of mineral soil, were tested for pH in the Soil Survey Research Branch laboratory with a Beckman Model H-2 pH meter. A soil paste consisting of distilled water and dry, sieved soil was allowed to stand 15 minutes before pH values were deter- mined. Field and laboratory pH meters used in this study were compared before the field season so that similar results could be expected. Field deter- minations of pH were made with a Beckman Model 180 pocket pH meter by inserting a glass electrode into mineral soil at the desired depth. Unincorporated organic matter. Changes wrought by fire in the unincorporated organic matter were determined by observation. Effect on physical properties Destruction of trees, ground vegetation, and organic matter exposes mineral soil to the elements, and changes in physical soil properties could therefore be anticipated. Soil temperature. Soil temperatures in burned-over areas were consist- ently higher than in unburned areas (Table 16). On the four study plots, temperature on recent burns averaged 10.5 F. higher at l-inch depths, and 9.7 F. higher at 3-inch depths than temperatures undermature forests. Tem- peratures were consistently higher at l-inch levels than at 3-inch levels. As . the age of burns increased, differences in temperatures were reduced. Removal of unincorporated organic matter, which acted as an . insulator, and absence of shade from the forest canopy and other vegetation, were largely responsible"' for increased soil· temperature. The increased capacity of the blackened soil surface to absorb ·heat in recently burned-over areas also contributed to a rise in soil temperature. Following a fire, the addition of charcoal to soil has been suggested by Bauer (1936) in California, and Lutz (1956) in Alaska as a factor in the increase of soil temperature. The capacity of charcoal to absorb heat was commented on by Tryon (1948). Isaac and Hopkins (1937) also felt that fire increased the capacity of soil to absorb heat. 69 TABLE 16 Temperatures in burned-over and unburned soil with differences tested by means of a t-test Temperature Difference Temperature Difference at 1" depth in temp. at 3" depth in temp. Description (average of (average of 6 readings) 6 readings) F F F F 5-year-old bum at Marchant Lake ................... 79.2 69.7 12.7** 14.2** Mature black spruce forest at Marchant Lake ... 66.5 55.5 13-year-old burn at Dodge Lake ......................... 82.0 64.5 11.8** 6.5** Mature black spruce forest at Dodge Lake ......... 70.2 58.0 5-year-old bum at Newnham Lake ................... 66.3 65.0 11.6** 14.2** Mature jack pine and black spruce forest at Newnham Lake ................. 54.7 50.8 22-year-old bum at Newnham Lake ................... 60.7 55.0 6.0* 4.2* Mature jack pine and black spruce forest at Newnham Lake ................. 54.7 50.8 ' ' *Significant at 5 per cent ' **Significant at 1 per cent j Kittredge (1938) found a 20 F. temperature difference between forested and burned-over areas at a l-inch depth. Most workers, with the exception of Shirley (1932), found increased soil temperature on burned-over areas. Shirley reported no difference in jack pine forests. A soil temperature inversion, with burned areas being colder and forested areas warmer, may be expected in winter because of reduced amounts of unincorporated organic matter to act as an insulating agent. Greater fluctu- ation in daily diurnal and nocturnal soil temperatures in recent bums is also probable. The changes in the amounts of radiation, insulation, wind, and humidity, in burned-over and forested areas should influence the soil temperatures. The influence of extreme soil temperatures on lichen regeneration is unknown, although it is generally believed that lichens can endure extremes of temperature without harmful effects. However, it can be assumed that the higher temperature of summer· soil, and increased wind action cau'sed by removal of vegetal cover will increase water evaporation, which in tum may result in desiccation of lichen stands. Lichens are strongly influenced by 70 l I abundance or lack of moisture. Smith (1921) reported that lichens, most of which are hygroscopic, are capable of enduring desiccation, but functions of active metabolism, respiration, and assimilation are impossible without water. The rise in surface-soil temperature following fire was ecologically favourable for germination and growth of some plants. Many of the fire- induced species in the early seral stages of succession may benefit from the increased soil temperature. Exfoliation of rocks, caused by the rapid expansion of the outer surfaces during fires, was noted at Marchant and Dodge Lakes. This may indicate the extreme temperature generated by forest fires in this region. Infiltration rate. Data on infiltration rates were collected at Dodge Lake. Results, as given in Table 17, indicate that infiltration rates on burned-over soil were more rapid than on unburned soil. Infiltration rates for 1 liter of water were 13.5 and 15.5 minutes on burned-over soil, and 17.0 and 18.25 minutes in unburned soil. The sample was too small to permit the application of statistical tests of significance. TABLE 17 Water infiltration rates on burned-over and unburned soil Description 13-year-old bum at Dodge Lake ........................................................................ . Mature black spruce forest at Dodge Lake ........................................................ .. Infiltration rate of 1 liter of water in minutes 1st Site 2nd Site 15.5 13.5 17.0 18.25 Veihmeyer and Johnston (1944) found that infiltration capacities of soil in burned-over chaparral areas of northern California were not changed by fire. In contrast, Johnson (1940) found infiltration rates on burned-over soil were reduced 40 per cent when compared with unburned soil. Kittredge- (1938), Bums (1952), and Beaton (1959), also found slower infiltration rates on burned-over areas than on undisturbed soil. Erosion. Erosion following forest fires in northern Saskatchewan is not serious. Destruction of plant cover, litter, and organic matter does not appear to result in more than light sheet erosion. Lack of erosion is explainable because of the light intensity of summer rainstorms, the soil's being frozen during a seven-month period, and the rapid colonization, following fire, of Marchantia polymorpha and mosses such as Polytrichum piliferum, P4! juniperinum, and Ceratodon purpureus. In addition, soils in the northern section are thin, seldom exceeding a few inches in depth. Water infiltration rates on bums in the study area, which appvar to be increased, would also reduce the threat of erosion. Gully erosion was noted only twice. In both cases, it was confined to sandy soils in southern regions of the study area. On two occasions the writer was present on recent bums during rain- storms. Little or no surface runoff resulted from rain pelting on exposed 71 TABLE 18 Chemical soil properties on burned-over and unburned soil Site Description 5-year-old burn at Marchant Lake ............... . Mature black spruce forest at Marchant Lake .... 13-year-old burn at Dodge Lake .................. . Mature black spruce forest at Dodge Lake . 5-year-old burn at Newnham Lake ............. . Mature jack pine and black spruce forest at Newnham Lake ........... . 22-year-old burn at Newnham Lake ............... . Mature jack pine and black spruce forest at Newnham Lake . *T =Trace Exchangeable cations in millequivalents per 100 grams of dry soil H Na K Ca Mg 4.1 7.0 3.4 3.9 1.9 2.4 1.2 2.4 .1 T* .4 .2 .1 T .2 .4 .2 T .2 .1 .1 T .2 .1 .1 T .4 .1 .2 T .2 .1 .1 T .4 .1 .2 T .2 .1 4.8 7.7 3.9 4.3 2.5 2.9 1.8 2.9 7.3 11.8 4.8 4.9 4.4 3.2 2.9 3.2 50 8.5 100 1.0 40 26.5 40 14.5 . 50 13.5 30 T 20 37.0 30 T surfaces. Any loss of soil from these thin mantles would be serious. In Alaska, Lutz (1956) also found erosion "surprisingly small". Wind erosion resulted in small sand dunes on twp recent bums in southern sections of the study area. ' Effect on chemical properties Determinations for nitrogen, available phosphorus, total exchange cation capacity, and exchangeable hydrogen, sodium, potassium, calcium, mag- nesium, and pH were made on samples from seven areas. Soil pH values were determined in the field and laboratory. Soil nutrients. Total exchange capacity was decreased in three of the four burned-over areas (Table 18). A 5-year-old bum showed a slight · increase in total exchange capacity. Of the individual cations, exchangeable hydrogen was reduced on each bum. Exchangeable calcium increased on three sites and remained the same on the fourth. Little difference was noted in exchangeable potassium, sodium, or magnesium. Increased calcium was recorded by Garren (1943) in his summary on effects of fire on soils in southeastern United States. In Alaska, Lutz (1956) found that a several-fold increase in exchangeable dalcium accompanied burning.· Reduced hydrogen ion concentration following burning on Vancouver Island was suggested by Godwin (1938). 72 Whil~ studying effects of slash burning on soil, Tarrant (1956) observed that light burning increased exchangeable potassium and had little appreciable effect on cation exchange capacity, while severe bums greatly increased exchangeable potassium and reduced cation e~change capacity. Burning of . logging slash increased soluble or available forms of potassium, calcium, and magnesium in investigations by Austin and Baisinger (1955). Total nitrogen abundance, as determined by the Kjeldhal method, did not follow any apparent trend. It increased on one bum, was reduced on two others, and remained the same on a fourth. Contradictory results were also reported in the literature. Barnette and Hester (1930), Isaac and Hopkins (1937), and Austin and Baisinger (1955) reported decreases in nitrogen, but Heyward and Barnette (1934) and Garren (1943) reported increases. Lutz (1956) reported an immediate reduction in total nitrogen, but increased available nitrogen following forest fires. Nitrogen in forest soils, LeBlanc (1954) believed, is the limiting factor in tree growth since it condi- tions the utilization of other nutrients. Nitrogen levels in both mature-forest soils and burned-over soils of the study area were considerably less than the 200 to 250 parts per million suggested by Bensend (1943) as optimum for growth of jack pine seedlings. Plants such as Epilobium angustifolium and Rubus idaeus var. aculeatissimus, which are generally regarded as nitrophilous species, were frequent to abundant on burned areas. Members of the nitro- philous Leguminosae family were entirely absent on both undisturbed and fire-destroyed areas. In each of. the four burned-over soils studied, phosphorus was more abundant than in unburned forest soils. Following fire in Alaska, an increase in the amount of available phosphorus in upper mineral layers was reported by Lutz (1956). Austin and Baisinger (1955) found more than a two-fold increase in phosphorus on burned-over plots in Washington and Oregon. Immediately following fire an increased supply of nutrients may be made available for plant growth. The possibility of the nutrients being leached from unprotected soil is increased also. Several years, after a fire the soil might be no more, or perhaps less fertile than before the fire. Research by Sampson· (1944) in California showed that the effect of fire on soil constituents is largely nullified by the second year and disappears in subsequent years. Ahlgren (1959) suggested that high concentrations of salts released from ash may kill or retard growth of seedlings by causing plasmolysis of root hairs and young roots. Toxic concentration levels would vary with the tolerance of certain plants. Spruce seedlings are damaged more easily than pine seed- lings, according to Heikinheimo (1915). The general increase of nutrients resulting from ash would be expected to stimulate the growth of some plan( species and inhibit others. Ahlgren (1960) found that oats and sunflowers showed increased vigor and size when grown in a certain soil which had been subjected to fire. Oats grown in soil subjected to a more severe summer fire, which resulted in more ash, showed no increase in size. Higher concentrations of many of the elements reported in Table 18 could have been expected in burned areas, if sampling had been extended to more recent forest fires. 73 TABLE 19 Soil pH in burned-over and unburned soils rH field sample pH field sample pH laboratory l-inch depth 3-inch depth sample 0-3 (median of (median of Description inch depth 6 readings) pH range 6 readings) pH range 5-year-old bum at Marchant Lake ............... 4.7 6.45 5.2-6.8 6.15 5.7-6.8 Mature black spruce at Marchant Lake ............... 4.4 5.00 4.2-6.3 5.60 4.5-6.8 13-year-old bum at Dodge Lake ......................... 4.6 5.45 5.2-6.2 5.65 5.2-6.1 Mature black spruce at Dodge Lake ......................... 4.5 5.15 4.7-5.2 5.35 5.0--5.5 5-year-old burn at Newnham Lake ................... 4.7 5.50 5.4-6.4 5.30 5.2-6.2 Mature jack pine and black spruce stand at Newnham Lake ............... 4.0 5.10 5.0-5.3 5.20 5.2-5.5 22-year-old bum at Newnham Lake ................... 5.2 5.90 5.4-6.2 5.80 5.2-5.9 Mature jack pine and black spruce stand at Newnham Lake ..................... 4.0 5.10 5.0-5.3 5.20 5.2-5.5 Soil pH. Field tests revealed that soils in burned-over areas gave increased pH values when compared with unburned forests (Table 19). Increases were greater at the l-inch depth than at the 3-inch depth. Soil samples measured in the:laboratory, although lower in pH value than field samples, showed the same trend of increased soil pH on recent bums. Variations in field and laboratory pH measurements of soil from northern Alberta were reported by the Soil Survey Research Branch. Staff members suggested that aluminium in the dried soil is changed, and the capacity of the soil to reabsorb water is reduced. The phenomenon, however, has not been explained thoroughly. Decreased acidity probably results from destruction of unincorporated organic material and addition of alkalis from wood ash to the soil. A similar . decrease has been reported by other workers. Marshall and Averill (1928), Barnette and Hester (1930), Lutz (1956), Beaton (1959), and others have reported increased pH values on burned-over soil. Garren (1943), in review- ing the literature on effects of fire on vegetation in southeastern United States, found that reduced soil acidity was reported. In Sweden, Uggla (1958) reported pH values were higher on bums than on adjacent unburned areas for about 25 years. The severity of thf bum would influence the period of years over which higher pH values would be retained. 74 Wilde (1958) gave pH range of 4.7 to 6.5 as optimum for white spruce growth. Increased soil pH may affect black spruce growth unfavorably for a period following forest fires since expected optimum values for black spruce growth would be lower than those for white spruce. Trumpener (1926) maintained that pH is an ecological factor of prime importance in the distribution of lichens. The growth and functioning of other plants are influenced by the hydrogen ion concentration also. Effect on unincorporated organic matter Forest fires in the study area, which appear to be generally severe, destroyed unincorporated organic matter on the forest floor, resulting in the exposure of as much as 35 to 50 per cent of the mineral-soil surface area or bedrock. In other parts of the bums, thickness of unincorporated organic matter was much reduced. Organic matter tended to be unincorporated in most of the region. In Washington, Isaac and Hopkins (1937) found that slash fires destroyed as much as 89 per cent of the organic matter. Powells and Stephenson (1934), Arend (1941), and many others have noted the destruction of unincorporated organic matter following forest fires. Soils in parts of the region studied were composed largely of organic matter. Fires that destroy organic matter in such areas are serious since bare rock is often exposed. Lengthy periods of time are required before organic matter will accumulate on exposed surfaces and support important food plants. Organic matter layers may be important sources of nutrients and may be closely related to the productivity of a site (Gagnon et al., 1958). Fires which destroy unincorporated layers of organic matter would be expected to increase nutrients available for plant growth, at least temporarily. Any increase may be temporary since leaching can occur more readily on the exposed soils in burned-over areas. In Oregon and Washington, Austin and Baisinger (1955) regarded removal of organic matter by fire as a major loss, probably having more- significance than other effects combined. They noted that unincorporated organic matter was a beneficial agent in: (1) improving soil aeration (2) storing plant nutrients (3) reducing moisture losses through evaporation (4) improving soil structure (5) inhibiting compaction and crusting (6) checking erosion (7) increasing water-holding capacities. Unincorporated matter acts as an insulator also, reducing temperature changes from day to day and diminishing seasonal fluctuations. Reduced frost penetration and delayed freezing of soil could be expected under :1 covering of unincorporated organic matter. The effects of fire on forest soils are favourable to certain soil properties and unfavourable to others. Whether or not the beneficial effects exceed the deleterious effects can be determined only after detailed studies of lichen and vascular plant ecology are made. Little is known about the effects of increased or reduced nutrient supplies on most of the lichens and vascular plants of the boreal forests. 75 EFFECTS OF FIRE ON WILDLIFE Effects of forest fires on wildlife are both direct and indirect. Direct effects involve destruction or injury of wildlife. Early in the fire season, young birds and mammals are victims of the ravages of forest fires. Although no charred carcasses were found in the study area, some animals may have succumbed. An important indirect effect is the change of a climax community-with its cover of trees, shrubs, bryophytes, and lichens~into a tangle of fallen snags and exposed soil, and later into a fireweed-grass-shrub community. Fire alters plant cover both in kind and quantity. These changes subsequently modify wildlife populations. Method Fecal pellet-group counts were made in each age class in each black spruce forest and jack pine forest sampled to determine the habitat preference of moose and barren-ground caribou. Within each 9.6-square-foot circular plot used for calculating vegetation production, moose and caribou pellets were counted. If six or more winter pellets of one type were found in a plot, they were recorded as a pellet group. Kelsall (1957) regarded six or more pellets as a group because barren-ground caribou generally drop their pellets while moving, leaving a point of concentration and several widely scattered pellets. Each pile of summer mo9se droppings was considered a pellet group. Pellet groups per plot were con:verted to pellet groups per acre. Effects of fire on other wildlife were detennined by observation. Big game animals Replacement of fire-destroyed climax communities with subclimax vegeta- tion results in subsequent changes in populations of barren-ground caribou and moose. Pellet group counts (Table 20) on six age classes in black spruce and white birch forests indicate that barren-ground caribou prefer the older forests, whereas moose favour the younger types. In forests over 120 years old, 586 caribou pellet groups per acre were found, compared with only 41 per acre on the 1 to 10 year age class. In contrast, 49 moose pellet groups per acre were present on the 1 to 10 year age class and only 9 were present in forests over 120 years old. Moose apparently prefer habitats less than 50 years old, but barren-ground caribou favour those exceeding 50 years of age. No moose pellet groups were found in jack pine forests (Table 21). Caribou pellets were found in older stands, but caribou's avoidance of young stands was evident. In a 65-year-old forest 1,702 caribou pellet groups·per acre were recorded. The large number of pellet groups in this forest indicates 76 TABLE 20 Average number of caribou and moose pellet groups per acre in six black spruce and white birch age classes Forest age class in years 1-10 11-30 31-50 51-75 76-120 Caribou pellet groups . ························ 41 28 199 510 331 Moose pellet groups .. ···················· .... 49 85 57 19 9 a caribou concentration area during a previous winter. 120 + 586 9 Barren-ground caribou feeding patterns were noted during the winter by aerial observations of transects on the study area. Feeding craters, which were dug in the snow by barren-ground caribou, were easily observed from the air. These observations agreed closely with the pellet-group counts. Such craters were confined largely to mature forests. Occasional trails and feeding craters were observed in recent bums where migrating animals crossed from one mature forest to another. Caribou TABLE21 Average number of caribou and moose pellet groups per acre in jack pine forests of various ages Forest age in years 5 15 16 35 43 pellet groups ....... ································ 0 0 0 57 0 Moose pellet groups ·········································· 0 0 0 0 0 65 1,702 0 In some recently burned areas the tangle of fallen snags and wind-throws made human movement difficult. Barren-ground caribou may experience similar difficulty. It is likely that young over-stocked birch stands impede caribou movement and lessen utilization of some areas. Crusted snow was another physical obstacle which may have induced barren-ground caribou to· avoid recent bums. Snow depths were similar on burned-over and mature forests on the study area during March 1961, but crusted snow was encoun- tered on recent bums. Crusted snow probably resulted from greater exposure to sunlight and reduced shelter from winds. Snow density and hardness, according to Pruitt (1959a), influence caribou movements and feeding patterns. In some areas of North America, such as the Kenai Peninsula of Alaska, forest fires have resulted in improved moose ranges and subsequently highe~ moose populations. A large moose population, however, was not evident in the study area. Only three moose were seen in more than three months of ground observation and several hours of observation from aircraft. Nearly 523,000 acres, or 26 per cent, of the total area have been burned in the last 30 years. The reason for such a small moose population is apparent from the forage productivity tables in Appendices D and E. Preferred moose browse in the post-fire vegetation was present in only small amounts. For 77 example, willow (Salix spp.) was scarce inupland foersts. In Alaska, Leopold and Darling (1953a) also suggested that passage of fire through forests did not always create optimum moose range. Effects of forest fire on wildlife may be good or bad, depending on animal utilization of the vegetation before and after the fire. In considering only two big-game species, fire appears to reduce the quality and quantity of winter range for barren-ground caribou and improve it only slightly for moose on upland forests of the study area. Carrying capacity per acre of mature forest for barren-ground caribou appears higher than that of early subclimax forests for moose. It appears that in terms of meat production, the area would be best managed for barren-ground caribou by protecting it from fire. A moderate black bear (Euarctos americanus) population found burned- over areas an excellent source of berries. Droppings and observations indicated frequent and widespread use of such areas by bears. Their feces appeared to be important in the distribution of seeds on recent bums. Fur-bearing animals Fur bearing animals are affected by fire also, since they are dependent on vegetative cover for food and shelter. The red squirrel (Tamiasciurus hudsonicus) was eliminated over much of the area. Squirrel populations were generally noted only in forest stands older than 50 years. Since squirrels are an item in the food chain of marten (Martes americana) and fisher (Martes pennanti), populations of these animals likewise may have been adversely affected. Forest fires may also destroy marten habitat since the species is regarded as a climax or near climax species (Miller, et al., 1955). At least one, and possibly two fur-bearers benefited from post-fire vegetation. Snowshoe hare (Lepus americanus) frequented younger forests in much larger numbers 1 than they did mature forests. Persistent fires north of Stony Rapids have gddually allowed quaking aspen to invade small areas. This food source may allow for a gradual increase in the present small popu- lation of beavers (Castor canadensis). Birds One example of a population change due to fire in the study area was. provided by the presence of sharp-tailed grouse (Pedioecetes phasianellus) on a recent bum and the confinement of numerous spruce grouse ( Canachites canadensis) to mature black spruce forests. Spruce. grouse were encountered almost daily throughout the summer field season in mature forests. The only other birds which demonstrated a habitat preference were slate-colored juncos (Junco hyemalis) and white-crowned sparrows (Zonotrichia leucophrys). Observa- tions of the slate-colored juncos were confined to coniferous· forests, and white-crowned sparrows were generally found in birch or mixed birch and black spruce forests. · · , The few generalizations discussed in the preceeding paragraphs" are the most obvious ones. Future ·studies might include detailed attention to the succession of animals following the alteration of habitat by forest fire. 78 SUMMARY AND CONCLUSIONS , The number of barren-ground caribou inhabiting the coniferous forests and tundra of Northern Canada has declined rapidly in recent years. This reduc- tion has placed hardships on many Indians and Eskimos who rely on barren- ground caribou for food and various other provisions. In an effort to arrest the decline, the Canadian Wildlife Service of the Department of Northern Affairs and National Resources began intensive barren-ground caribou investigations in 1948. Smce the destruction of climax biota by forest fires had been suggested as one cause for the decline of barren-ground caribou, the Service started a preliminary study to evaluate the effects of fire on a key wintering area in northern Saskatchewan in July, 1959. Comments on forest fires in the journals of early explorers, and the presence of charcoal in soil profiles indicate that the relationship between forest fires and caribou is not a recent one. Vegetation maps of the study area, however, indicate that the acreage burned per year by forest fires has increased 1.4 times in the last 15 years compared with the previous 60 years and 3.1 times when compared with the period extending from 1840 to 1884. One of the most obvious effects of forest fires on the winter range of barren-ground caribou is reduction of forage in both quantity and quality. Forage production was determined for six forest age classes. Black spruce and seral white birch stands produced an average of 290, 492, 604, 641, 830, and 942 pounds of air-dry forage per acre in the 1 to 10, 11 to 30, 31 to 50, 51 to 75, 76 to 120, and over 120 year age classes respectively. Accumulated production of high value lichens, which are the preferred winter ·food of ~ barren-ground caribou, was 1, 12, 61, 66, 205, and 264 pounds per acre, air-dry weight, in the six age classes, respectively. Grass, grass-like plants, and herbs produced 185 pounds of forage per acre in the 1 to 10 year age class, but less than 15 pounds per acre in subsequent age classes. Shrub pro- duction was low during the first post-fire age class and was fairly constant at approximately 400 pounds per acre throughout the others. Production in jack pine forest may follow the same general trend as in black spruce forest, but the type was too limited in extent to draw any definite conclusions. Burning of the winter range results in only a temporary reduction in range productivity, with the exception of high value "reindeer lichens". In northern Saskatchewan, a century or more is required for fire-destroyed "reindeer lichens" to reach their former abundance. Annual growth rates of Cladonia alpestris and C. rangiferina were approximated at 4.1 and 4.9 milli- metres respectively. The two lichens were found infrequently in forests younger than 30 years of age. 79 In mature coniferous forests, arboreal lichens may make substantial contributions to the winter diet of barren-ground caribou, particularly under severe weather conditions. Approximately 628 pounds of accessible arboreal lichens per acre were present in mature black ·spruce forests compared with 375 pounds per acre of accessible arboreal lichens in mature jack pine forests. A quantity of those lichens is not available to barren-ground caribou since the lichens are interwoven with the needles and branches of the conifers. Lichens on fallen trees, lichens dislodged by wind or snow, and lichens growing within 10 feet of the ground were considered accessible to the animals. As a food source, Alectoria jubata is thought to be the most important arboreal lichen in the study area. The first, second, and third stages of secondary plant succession follow- ing forest fires are described. The first stages of succession were character- ized by rapid changes in species composition. Floristic changes were less rapid as the stages of succession advanced. The results of investigations of soil properties indicated that several changes were wrought by forest fires. Fire increased water infiltration rates on soils in one area which formerly supported a black spruce forest. Summer temperatures of exposed mineral soils in burned-over areas were higher at l-inch and 3-inch depths than in unburned areas. Soils on burned areas may be subject to greater daily and seasonal temperature extremes than soils sup- porting mature forests. Soil erosion appeared to be a minor problem. On recent bums, acidity of soil was reduced for several years. Exchangeable cal- cium increased and total exchange capacity decreased on three of four burned- over soils. Amounts of exchangeable hydrogen were reduced, while amounts of available phosphorus increased in each of the burned-over soils. No trends were indicated for total nitrogen, or exchangeable potassium, magnesium, and sodium following forest fires. Destruction of unin<;orporated organic matter by forest fires was a serious loss. · The full effect of these changes in soil properties on plant life will not be fully understood until ecological studies on plant requirements have been made. Pellet-group counts and aerial surveys indicate that barren-ground caribou prefer climax forests and advanced successional stages of forest growth. Moose showed a preference for early successional stages of forest growth, particularly the post-fire stage 10 to 30 years after a fire. Neither species, however, limited itself to any one age class. Other mammals and birds were influenced by changes in habitat following forest fires. From the results of this preliminary study on only one winter range area, it is impossible to determine the extent to which forest fires have influ-.. enced the decline of the barren-ground caribou population. But, if the effect of fire on plant productivity, plant succession, and growth rates of "reindeer lichens" are similar throughout the winter range, then there would be little doubt that forest fires have been one of the principal causes of the decline. Regardless of the reason for the decline, the present winter range, with its vast fire-destroyed areas, will place a restriction on caribou numbers for at least a few decades. 80 SOMMAIRE ET CONCLUSION Le nombre de rennes arctiques habitant les forets de coniferes · et ll! toundra du Nord canadien a rapidement diminue au cours des demieres annees. Cette reduction a cause des privations a un grand nombre. d'Indiens et d'Esquimaux qui comptent sur le renne arctique· pour leur no:urriture et divers autres besoins. Dans un effort pour arreter cette diminution, le Service canadien de la faune du ministere du Nord canadien et des Ressources natio- nales a entrepris, en 1948, des recherches intensives sur le renne arctique. Etant donne qu'on a suppose que la destruction de la faune et de la flare climacique par les incendies de foret etait une des causes de la diminution du nombre de rennes arctiques, le Service a entrepris, en juillet 1959, une etude preliminaire afin d'estimer les effets des incendies dans une importante region d'hivemage du nord de la Saskatchewan. Les commentaires sur les incendies de foret qu'on trouve dans les notes des premiers explorateurs et Ia presence de charbon dans les coupes. de sols indiquent que le rapport entre le nombre de rennes et les incendies de foret n'est pas un phenomene recent. Cependant, les cartes de la flare de la region etudiee indiquent que la superficie devastee chaque..annee par les incendies de foret a augmente de 1.4 fois au cours des 15 demieres annees en comparaison des 60 annees precedentes, et de 3.1 fois en comparaison de la periode s'etendant de 1840 a 1884 .. Un des effets les plus evidents des incendies de foret sur l'habitat d'hiver du renne arctique est une reduction· a la fois de Ia quantite et de Ia qualite du fourrage. On a determine Ia production de fourrage dans des forets reparties en six classes selon leur age. Les peuplements d'epinette noire et les peuple- ments de succession de bouleau a papier ant produit une moyenne de 290, 492, 604, 641, 830 et 942 livres de fourrage secbe a l'air a l'acre dans les classes de 1 a 10, 11 ~ 30, 31 a 50, 51 a 75, 76 a 120 et plus de 120 ans, respectivement. La production accumulee de lichens a grande valeur nutritive, qui constituent la nourriture d'hiver preferee du renne arctique, a ete de 1, 12, 61, 66, '205 et 264 li{.res a l'acre (secbe a l'air) respectivement dans les six classes d'age. Les herbacees et les plantes qui leur sont apparantees ont produit 185 livres de fourrage al'acre dans la foret de 1 a 10 ans, mais mains de 15 livres a l'acre dans les autres classes de foret. La production arbustive a ete faible dans la premiere classe, mais assez constante a environ 400 livres a l'acre dans les autres. 11 se peut que la production des forets de pin gris suive Ia meme tendance generale que celle des forets d'epinette noire, -mais le peuplement avait une etendue trap limitee pour qu'on puisse tirer des conclusions precises. Le brulage des paturages d'hiver ne cause qu'une diminution temporaire de leur productivite, sauf en ce qui conceme le precieux "lichen des caribous". Dans le nord de Ia Saskatchewan, il faut un siecle ou plus aux "lichens des caribous" detruits par le feu pour retrouver leur ancienne abondance. On a calcule que Cladonia alpestris et C. rangiferina ont une croissance ~nnuelle d'environ 4.1 et 4.9 millimetres, respectivement. On trouve rareme:gt ces deux lichens dans des forets de mains de 30 ans. 1 Dans les forets de coniferes adU:ltes, les lichens corticoles peuvent contri- buer sensiblement a la nourriture d'hiver du renne arctique, surtout lorsqu'il 81 fait mauvais temps. II y avait environ 628 livres de lichens corticoles accessi- bles a l'acre dans les forets d'epinettes noires adultes, en comparaison de 375 livres dans les forets de pins gris adultes. Une partie des lichens n'est pas accessible au renne arctique, car ils sont entrelaces avec les aiguilles et les branches des arbres. On a considere comme accessibles aux animaux les lichens poussant sur les arbres tombes, ceux qui ont ete detaches par le vent ou la neige et ceux qui poussent sur les arbres jusqu'a dix pieds du sol. On croit que, comme source de nourriture, Alectoria jubata est le lichen corticole le plus important de la region etudiee. Une description est donnee des premier, deuxieme et troisieme stades de la succession secondaire des plantes a la suite d'un incendie de foret. Les premiers stades de la succession etaient caracterises par des changements rapides d'especes. Les changements floristiques devenaient moins rapides a mesure qu'on avan<;:ait dans les stades de succession. Les resultats des recherches sur les proprietes des sols indiquent que les incendies de foret leur ont apporte plusieurs changements. Le feu a augmente le taux d'infiltration de l'eau dans le sol dans une region recouverte aupara- vant d'epinettes noires. En ete, la temperature du sol mineral denude dans les aires brftlees etait plus elevee a une profondeur de 1 et de 3 pouces qtie dans les aires non bn1lees. II se peut que le sol des aires bn1lees soit soumis a de plus grands ecarts de temperature joumaliere et saisonniere que le sol des forets adultes. L'erosion du sol a semble n'etre qu'un probleme d'importance secondaire. Dans les brulis recents, l'acidire du sol a ete plus faible durant plusieurs annees. Le teneur en calcium echangeable a augmente, tandis que la capacite totale d'echange a diminue dans trois terrains bn1les sur quatre. La quantite d'hydrogene echangeable a diminue, alors que la quantite de phos- phore assimilable a augmente dans chacun des bn1lis. Aucun changement n'a ete decele en ce qui conceme l'azote total, nile potassium, le magnesium et le S9dium echangeables a la ~uite d'incendies de foret. La destruction par le feu de matieres organiques non incorporees au sol a ete bien desastreuse. Tout l'effet de ces changements,de proprietes du sol sur la vie des plantes ne pourra etre bien compris qu'apres des etudes ecologiques sur les besoins des plantes. Le denombrement de petits groupes et des releves aeriens indiquent que le renne arctique prefere les forets climaciques et celles qui sont parvenues a un stade avance de succession. Les orignaux, eux, montrent une certaine preference a l'endroit des forets aux premiers stades de succession, en particu- lier le stade qu'on trouve entre 10 et 30 ans apres un incendie de foret. Aucune des especes, cependant, ne se limite a une seule des classes d'age. Les autres mammiferes et les oiseaux ont aussi subi I' influence des changements d'habitat qu'ont entraines les incendies de foret. Les resultats de cette etude preliminaire d'un seul paturage d'hiver ne permettent pas de determiner dans quelle mesure la diminution de la popula- tion de rennes arctiques est attribuable aux incentries de foret. Cependant, si les effets de l'incendie sur la prodiktivite vegetate, sur la succession de plantes et sur la croissance des "lichens des caribous" sont les memes dans tout l'habitat d'hiver, on ne peut guere douter que les incendies de foret ai7nt ete une des principales causes de cette diminution. Quelle que soitla raison de • .cette derniere, !'habitat d'hiver actuel, avec ses vastes bn1lis, va restreindre le · de tennes pour au moins quelques decennies. LITERATURE CITED Ahlgren, C. E. 1959. Some effects of fire on forest reproduction in northeastern Minnesota. J. Forestry 57: 194-200. Ahlgren, C. E. 1960. Some effects of fire on reproduction and growth of vegetation in northeastern Minnesota. Ecology 41:431-445. Ahti, T. 1957. Newfoundland lichen stands and the wintering range of caribou. Unpubl. rept. in the files of the Newfoundland Dept. of Mines and Resources, Wildl. Div. 88 p. Ahti, T. 1959. Studies on the caribou lichen stands of Newfoundland. Annales Botanici Societatis Zoologicae Botanicae Fennicae 'Vanamo' 30:4:41-44. Allen, G. M. 1942. Extinct and vanishing mammals of the Western Hemisphere. Am. Com. Intern. Wildl. Protection. Spec. Publ. No. 11. 620 p. American Ornithologists' Union. 1957. Check-list of North American birds. 5th ed. American Ornithologists' Union. Ithaca, New York. 691 p. Anderson, R. M. 1938. The present status and distribution of the big game mammals of Canada. North Am. Wildl. Conf. 3:390-406. Andreev, V. N. 1954. The growth of forage lichens and the methods for their regula- tion. (In Russian) Tr. Botan. Inst. AN S.S.S.R. (Acta lnst. Botan. Acad. Sci., U.S.S.R.) Ser. III. Geobotanika 9:11-74. Arend, J. L. 1941. Infiltration rates of forest soils in the Missouri Ozarks as affected by woods burning and litter removal. J. Forestry 39:726-728. Association of Official Agricultural Chemists. 1955. Official and tentative methods of analysis of the Association of Official Agricultural Chemists. Washington, D.C. 8th ed. 1008 p. Austin, R. C. and D. H. Baisinger. 1955. Some effects of burning on forest soils of western Oregon and Washington. J. Forestry 53:275-280. Baker, A. S. 1956. Methods for analyzing soil extracts of potassium, calcium, and magnesium using the Beckman D.U. flamephotometer. Soil and Crop Sci. Soc. Florida Proc. 16:272-282. Banfield, A. W. F. 1954. Preliminary investigation of the barren-ground caribou, Pts. I• and II. Canadian Wildl: Serv., Wildl. Mgmt. Bull. Ser. 1, 10A:1-79, 10B:1-112. Banfield, A. W. F., and J. S. Tener. 1958. A preliminary study of the Ungava caribou. J. Mammal. 39:560-513. Barnette, R. M., and J. B. Hester. 1930. Effect of burning upon the accumulation of organic matter in forest soils. Soil Sci. 29:281-284. Bauer, H. L. 1936. Moisture relations in the chaparral of the Santa Monica Mountains, California. Ecol. Monographs 6:409-454. . Beaton, J. D. 1959. The influence of burning on the soil in the timber range area of Lac le Jeune, British Columbia. I. Physical properties. II. Chemical prop- erties. Canadian J. Soil Sci. 39:1-11. • Beck, W. H. 1958. A guide to Saskatchewan mammals. Saskatchewan Nat. Hist. Soc. Spec. Publ. No. 1. 52 p. Bell, R. 1889. Forest fires in Northern Canada. Proc. Am. Forestry Congr. p. 50-55. Bensend, D. W. 1943. The effect of nitrogen on the growth and drought resistance of jack pine seedlings. Univ. Minn. Agr. Exp. Sta., Tech. Bull. 163. 63 p. Blake, D. A. W. 1956. · Geological notes on the region south of Lake Athabasca and Black Lake Saskatchewan and Alberta. Canada Dept. Mines Tech. Surveys, Geol. Survey. Paper 55-33. 12 p. Buckley, J. L. 1958. Effects of fire on Alaskan Wildlife. Proc. Soc. Am. Foresters. p. 123-126. 83 Bums, P. Y. 1952. Effect of fire on forest soils in the pine barren region of New Jersey. Yale Univ. School of Forestry Bull. 57. 50 p. Campbell, R. S., and J. T. Cassady. 1955. Forage weight inventories on southern forest ranges. Southern Forest Exp. Sta. Occasional Paper 139. 18 p. Camsell, C., and W. Malcolm. 1919. The Mackenzie River basin. Canada Dept. Mines, Geol. Survey, Mem. 108. 154 p. Carson, J. A., A. L. Mathieu, and M. D. Scheelar. 1962. Note on the use of flooding solutions in the determination of metallic exchangeable cations, utilizing a Beckman DU flame spectrophotometer. Canadian J. Soil Sci. 42:317-318. Choiniere, L. 1956. Dosage des cations echangeables du soil par le spectrophotometre a flamme Beckman. Canadian J. Agr. Sci. 36:203-204. Clarke, C. H. D. 1940. A biological investigation of the Thelon Game Sanctuary. Nat. Mus. Canada, Bull. No. 96. 135 p. Cormack, R. G. H. 1953. A survey of coniferous forest succession in the eastern Rockies. Forestry Chronicle 29:218-232. Cringan, A. T. 1957. History, food habits and range requirements of the woodland caribou of continental North America. North Am. Wild!. Conf. 22:485-501. Cringan, A. T. 1958. Influence of forest fires and fire protection on wildlife. Forestry Chronicle 34:25-30. Darling, F. F. 1954. Caribou, reindeer and moose in Alaska. Oryx 2:280-285. Darling, F. F. 1956. Pelican in the wilderness. Allen & Unwin, London. 380 p. de Vos, A. 1948. Status of the woodland caribou in Ontario. Sylva 4:17-23. Dugmore, A. A. R. 1913. The romance of the Newfoundland caribou, an intimate account of the life of the reindeer of North America. William Heinemann, London. 191 p. Edwards, R. Y. 1954. Fire and the decline of a mountain caribou herd. J. Wild!. Mgmt. 18:521-526. Edwards, R. Y., and R. W. Ritcey. 1960. Foods of caribou in Wells Gray Park, British Columbia. Canadian Field-Nat. 74:3-7. Edwards, R. Y., J. Soos, and R. W. Ritcey. 1960. Quantitative observations on Epidendric lichens used as food by caribou. Ecology 41:425-431. Femow, B. E. 1912. Forest conditions of Nova Scotia. Canada Comm. Conserv. Ottawa. 93 p. Powells, H. A., and R. E. Stephenson. 1934. Effect of burning on forest soils. Soils Sci. 38:175-181. Furnival, G. M. 1941a. Porcupine River, northern Saskatchewan. Canada Dept. Mines and Resources. Map 658A. Furnival, G. M. 1941b. Stony Rapids, northern Saskatchewan. Canada Dept. Mines and Resources. Map 659A. Gagnon, D., A. Lafond, and L. P. Amiot. 1958. Mineral nutrient content of some forest plant leaves and of the humus layer as related to site quality. Canadian J. Bot. 36:209-220. Garren, K. H. 1943. Effects of fire on vegetation of the southeastern United States. Botan. Rev. 9:617-654. Godwin, G. 1938. A regeneration study of representative Jogged-off lands on Vancouver Island. Forestry Chronicle 14:61-83. Harper, F. 1931. Physiographic and faunal areas in the Athabaska and Great Slave Lakes region. Ecology 12:18-32. Harper, F. 1932. Mammals of the Athabaska and Great Slave Lakes region. J. Mammal. 13: f9-26. Harper, F. 1955. The barren ground caribou of Keewatin. Univ. Kansas Mus. Nat. Hist. Misc. Pub!. No. 6. 163 p.. . Heikiriheimo, 0. 1915. Der Einfluss der Brandwirtschaft auf die Walder Finnlands. Acta Forestalia Fennica 4:1-264. (Original not seen; cited f~om Ahlgren, C. E., 1959.) . Heyward, F., and R. M. Barnette. 1934. Effect of frequent fires on chemical composi- tion of forest soils in the longleaf pine region. Florida Agri. Exp. Sta., Tech. Bull. 265. 39 p. t Hind, H. Y. 1863. Explorations in the interior of the Labrador Peninsula, the country of the Montagnais and Nasquapee Indians. Longman, Green, Logman, Roberts, and Green, London. Vol. 1, 351 p. 84 Hoare, W. H. B. 1927. Report of investigations affecting Eskimo and wild life, District of Mackenzie, 1924-1925-1926. Northwest Territories Branch, Canada Dept. of Interior. 44 p. (Mimeo.) Hoare, W. H. B. 1930. Conserving Canada's musk-oxen. Canada Dept. of Interior. 53 p. . Hornby, J. 1934. Wild life in the Thelon River area, Northwest Territories, Canada. Canadian Field-Nat. 48:105-111. Hustich, I. 1951. The lichen woodlands in Labrador and their importance as winter pastures for domesticated reindeer. Acta Geog. 12:1-48. Isaac, L. A., and H. G. Hopkins. 1937. The forest soil of the Douglas fir region, and changes wrought upon it by logging and slash burning. Ecology 18:264-279. Itkonen, T. I. 1948. Suomen Lappalaiset. W~ Soderstrom Oy. Porvoo. (Original not seen; cited from Hustich, I., 1951.) Johnson, W. M. 1940. Infiltration capacitY of a forest soil as influenced by litter. J. Forestry 38:520. · Kelsall, J. P. 1957. Continued barren-ground studies. Canadian Wildl. Serv. Wildl. Mgmt. Bull. Ser. 1, 12:1-148. Kelsall, J. P. 1960. Co-operative studies of barren-ground caribou 1957-58. Canadian Wildl. Serv., Wildl. Mgmt. Bull. Ser. 1, 15:1-145. Kendall, R. H., and L. Sayn-Wittgenstein. 1959. An evaluation of the relascope. Forestry Branch, Dept. of Northern Affairs and ,Nat. Resources. Tech. Note 77. 26 p. Kittredge, J. 1938. Compartive infiltration in the forest and open. J. Forestry 36:1156-1157. LeBlanc, H. 1954. A new approach to the northern spruce regeneration problem. Forestry Chronicle 30:372-379. Leopold, A. S., and F. F. Darling. 1953a. Wildlife in Alaska. Ronald Press Co., New York. 129 p. Leopold, A. S., and F. F. Darling. 1953b. Effects of land use on moose and caribou in Alaska. North Am. Wildl. Conf. 18:553-562. Loughrey, A. G. 1952. Caribou winter range study, 1951-52. Unpubl. rept. in files of Canadian Wildl. Serv., Ottawa. 30 p. Low, A. P. 1897. Report on explorations in the Labrador Peninsula along the East Main, Koksoak, Hamilton, Manicuagan, and portions of other rivers, in 1892-93-94-95. Geol. Survey of Canada, Ann. Rept. for 1895. Vol. 8L. 387 p. Lutz, H. J. 1956. Ecological effects of forest fires in the Interior of Alaska. U.S. Dept. Agr. Tech. Bull. 1133. 121 p. Lutz, H. J. 1959. Aboriginal man and white man as historical causes of fires in the boreal forest, with particular reference to Alaska. Yale Univ. School of Forestry Bull. 65. 43 p. Manning, T. H. 1946. Bird and mammal notes from the east side of Hudson Bay. 0 Canadian Field-Nat. 60:71-85. Marshall, R., and C. Averill. 1928. Soil alkalinity on recent burns. Ecology 9:533. Mathieu, A. L., and N. Burtch. 1961. A modification for the Beckman DU flame spectrophotometer. Canadian J. Soil Sci. 41 : 134-13 5. Mathieu, A. L., and J. A. Carson. 1961. An air-jet stirrer for the Beckman DU flame spectrophotometer. Canadian J. Soil Sci. 41:136-137. Miller, R. G., R. W. Ritcey, and R. Y. Edwards. 1955. Live-trapping marten in British Columbia. Murrelet 36: leg. Moisan, G. 1955. The caribou of Gaspe: A preliminary study of range conditions and herd status. Unpubl. M.S. thesis, Cornell Univ., Ithaca, New York. .. Mowat, F. 1958. Coppermine journey. McClelland & Stewart Limited, Toronto. 144 p. Munsterhjelm, E. 1953. The wind and the caribou. George Allen and Unwin Limited London. 234 p. · ' Munsterhjelm, E. 1957. Fool's gold. Macmillan Company of Canada, Toronto. 250 p. Norris, J. J. 1943. Botanical analyses of stomach contents as a method of determining forage consumption of range sheep. Ecology 24:244-251. Palmer, L. J. 1926. Progress of reindeer grazing investigations in Alaska. U.S. Dept. Agr. Bull. 1423. 37 p. Palmer, L. J. 1940. Caribou versus fire in interior Alaska. Unpub. rept. in files of U.S. Fish and Wild!. Service. Juneau, Alaska. 5 p. 85 Palmer, L. J. 1941. Caribou versus fire in interior Alaska. Unpubl. rept. in files of U.S. Fish and Wild!. Service. Juneau, Alaska. 13 p. Pechanec, J. F., and G. D." Pickford. 1937. A weight estimate method for the deter- mination of range or pasture production. Am. Soc. Agron. 29:894-904. Perez-Llano, G. A. 1944. Lichens-their biological and economic significance. Botan. Rev. 10:1-65. Pike, W. 1892. The barren ground of northern Canada. Macmillan and Co., New York. 300 p. . Porsild, A. E. 1954. Land use in the Arctic. Canadian Geog. J. 48:232-243; 49:20-31. Prince, A. L. 1945. Determination of total nitrogen, ammmtia, nitrates, and nitrites in soils. Soil Sci. 59:47-52. Pruitt, W. 0. 1959a. Snow as a factor in the winter ecology of the barren ground caribou. Arctic 12:158-179. Pruitt, W. 0. 1959b. Letter of November 30, 1959 to the author. Raup, H. M., and C. S. Denny. 1950. Photo interpretation of the terrain along the southern part of the Alaska highway. U.S. Geol. Survey Bull. 963D:95-135. Richardson, J. 1829. Fauna Boreali-Americana Part !-Quadrupeds. J. Murray, London. 300 p. Robinson, R. R. 1953. Forest management and protection on the Alaskan public domain. Proc. Alaska Sci. Con£. 4:92-94. Rousseau, J. 1951. Basic principles for the protection of the barren ground caribou and reindeer breeding in Quebec. The Province of Quebec Assoc. for the Protection of Fish and Game. Ann. Rept. for 1951. 28-35 p. Sampson, A. W. 1944. Plant succession on burned chaparral lands in northern Cali- fornia. California Agr. Exp. Sta. Bull. 685. 144 p. Sarvas, R. 1937. Ueber die Entwicklung der vegetation auf den Waldbrandflachen Nordifinnlands. Silva Fennica 44:1-64. (Original not seen; cited froin Hustich, I., 1951.) Scott, W. B. 1958. A checklist of the freshwater fishes of Canada and Alaska. Royal Ontario Mus., Toronto: 30 p. Scotter, G. W. 1961a. Botanical collections in the Black Lake region of northern Saskatchewan (1960). Blue Jay 19:28-33. Scotter, G. W. 1961b. Summer observations of birds in northern Saskatchewan, 1960. Blue Jay 19:70-74. Shirley, H. L. 1932. Does light burning stimulate aspen suckers? J. Forestry 30:419-420. Skoog, R. 0. 1956. Range, movements, population, and food habits of the· Steese- Fortymile caribou herd. Unpubl. M. S. thesis. Univ. of Alaska, College, Alaska. Smith, A. L. 1921. Lichen~. Univ. Press, Cambridge. 464 p. Tarrant, R. F. 1956. Effecti> of slash burning on some soils of the Douglas-fir region. Soil Sci. Soc. Am. Proc. 20:408-411. Thomson, J. W., and G. W,. Scotter. 1961. Lichens of northern Saskatchewan. Bryologist 64:240-247. Trumpener, E. 1926. Uber die Bedeutung der Wasserstoffionen-Konzentration fur die Verbreitung von Flechten. Bot. Centralblatt Beihefte. Abt. 1. 42:321-354. (Original not seen; cited from Prez-Llano, G. A., 1944.) Tryon, E. H. 1948. Effect of charcoal on certain physical, chemical, and biological properties of forest soils. Ecol. Monographs 18:81-115. Tyrrell, J. B. 1894. An expedition through the barren lands of northern Canada. Geog. J. 4:437-450. Tyrrell, J. B. 1916. David Thompson's narrative of his explorations in western America, 1784-1812. The Champlain Soc., Toronto. 582 p. Tyrrell, J. B. 1934. Journals of Samuel Hearne and Philip Turnor between the years 1774 and 1792. The Champlain Soc., Toronto. 611 p. Uggla, E. 1958. Ecological effects of fire on north Swedish forests. Almqvist and Wiksells Boktryckeri Ab. Uppsala. 18 p. Veihmeyer, F. J., and C. N. Johnston. 1944. Soil-moisture records from burned and unburned plots in certain grazing areas of California. Trans. Am. Geophysical Union. Pt. I, 25:72-88. Wilde, S. A. 1958. Forest soils. Ronald Press Co., New York. 537 p. 86 APPENDICES Appendix A CHECKLIST OF THE FLORA ON THE BARREN-GROUND CARIBOU WINTER RANGE OF NORTHERN SASKATCHEWAN LICHENES CALICIACEAE . Chaenotheca chrysocephala (Turn.) Th. Fr. CYPHELIACEAE Cyphelium tigillare Ach. PANNARIACEAE Pannaria pezizoides (Web.) Trev. Massalongia carnosa (Dicks.) Korber PELTIGERACEAE Nephroma arcticum (L.) Torss. Nephroma bellum (Spreng.) Tuck. Peltigera aphthosa (L.) Willd. Peltigera canina (L.) Willd. Peltigera canina var. rufescens Peltigera canina var. spuria Pelltigera canina var. ulorrhiza Peltigera malacea (Ach.) Funck Peltigera pulverulenta (Tayl.) Nyl. GYALECTACEAE Microphiale diluta (Pers.) Zahlbr. LECIDEACEAE Lecidea alaiensis V ainio · Lecidea assimilata Nyl. Lecides auriculata Th. Fr. Lecidea berengeriana (Mass.) Th. Fr. Lecidea cuprea Sommer£. Lecidea granulosa (Ehrh.) Ach. Lecidea lapicida Ach. var. ochracea (Nyl.) Vainio Lecidea macrocarpa (D.C.) Th. Fr. Lecidea (Psora) ostreata (Hoffm.) Schaer. Mycoblastus sanguinarius (L.) Norm. Rhizocarpon grande (Florke) Arn. Rhizocarpon lindsayanum Ras. Rhizocarpon obscuratum (Ach.) Mass. CLADONIACEAE Baeomyces rufus (Huds.) Rabenh. Cladonia alpestris (L.) Rabenh. Cladonia alpicola (Flot.) Vain. Cladonia amaurocraea (Florke) Schaer. Cladonia bacillaris (Ach.) Nyl. Cladonia botrytes (Hag.) Willd. ... 87 CLADONIACEAE (continued) Cladonia cariosa (Ach.) Spreng. Cladonia cameo/a Fr. Cladonia cenotea (Ach.) Schaer. Cladonia coccifera (L.) Zopf Cladonia cornuta (L.) Schaer. Cladonia crispata (Ach.) Plot. Cladonia cristatella Tuck. Cladonia deformis (L.) Hoffm. Cladonia gracilis (L.) Willd. Cladonia gracilis var. dilatata (Hoffm.) Cladonia mitis Sandst. Cladonia multiformis Merr. f. finkii (Vainio) Evans Cladonia pyxidata (L.) Fr. Cladonia pyxidata var. neglecta (Flk.) Cladonia rangiferina (L.) Web. Cladonia turgida (Ehrh.) Hoffm. Cladonia uncia/is (L.) Web. Cladonia verticillata (Hoffm.) Schaer. Stereocaulon alpinum Laur. Stereocaulon dactylophyllum Florke Stereocaulon paschale (L.) Hoffm. Stereocaulon tomentosum Fr. UMBILICARIACEAE Actinogyra muhlenbergii (Ach.) Scholander Lasallia papulosa (Ach.) Llano Umbilicaria hyperborea (Ach.) Hoffm. Umbilicaria vellea (L.) Ach. LECANORACEAE Haematomma lapponicum Ras lcmadophila ericetorum (L.) Zahlbr. Lecanora pachythallina Lynge Lecanora rubina (Viii.) Ach. Ochrolechia frigida (Sw.) Lynge Ochrolechia inaequatula INyl.) Zahlbr. Candelariella vitellina (Ehrh.) Mull. Arg. PARMELIACEAE 88 Parmeliopsis ambig~.:a (Wulf.) Nyl. 'Parmeliopsis hyperopia (Ach.) Vain. Parmelia centrifuga (L.) Ach. Parmelia olivacea (L.) Ach. Parmelia omphalodes (L.) Ach. Parmelia physodes (L.) Ach. Parmelia rudecta Ach. Parmelia saxatilis (L.) Ach. Parmelia separata Th. Fr. Parmelia sinuosa Nyl. Parmelia subobscura Vainio Parmelia sulcata Tayl. Cetraria ciliaris Ach. Cetraria commixta (Nyl.) Th. Fr. Cetraria crispa (Ach.) Nyl. Cetraria cucul!ata (Bell.) Ach. Cetraria glauca (L.) Ach. Cetraria hepatizon (Ach.) Vain. Cetraria islandica (L.) Ach. Cetraria nivalis (L.) Ach. Cetraria pinastri (Scop.) S. Gray Cetraria sepincola (Ehrh.) Ach. j USNEACEAE Alector:ia jubata (L.) Ach. Alectoria nadvornikiana Gyel. Alectoria nidulifera Norrl. Evernia mesomorpha Nyl. Ramalina pollinaria (Westr.) Ach. Usnea dasypoga (Ach.) Rohl. Usnea glabrescens (Nyl.) Vainio spp. glabr:ella Mot. Usnea hirta (L.) Wigg. CALOPLACACEAE Caloplaca cerina (Ehrh.) Th. Fr. Caloplaca elegans (Link.) Th. Fr. Caloplaca flavovirescens (Wulf.) D. T. & S. Caloplaca ulmorum (Fink) Fink TELOSCHISTACEAE Xanthoria Candelaria (L.) Arn. Xanthoria fallax (Hepp) Arn. BUELLIACEAE . Rinodina lecideoides (Nyl.) Vain. Rinodina oreina (Ach.) Mass. PHYSCIACEAE Physcia dubia (Hoffm.) Lett. LICHENES IMPERFECT! Crocynia membranacea (Dicks.) Zahlbr. Crocynia neglecta (Nyl.) Hue ·· HEPATICAE Ptilidium ciliare (L.) Hampe Marchantia polymorpha L. SPHAGNA Sphagnum capillaceum (Weiss.) Schrank Sphagnum capillaceum var. tenellum (Schimp.) Andr. MUSCI Andreaea rupestris Hedw. Ceratodon purpureus (Hedw.) Brid. Dicranum elongatum Schwaegr. Dicranum rugosum (Hoffm.) Brid. Aulacomnium palustre (Hedw.) Schwaegr, Hedwigia ciliata (Hedw.) P. Beauv. Neckera pennata Hedw. Pleurozium schreberi (Brid.) Mitt. Ptilium crista-castrensis (Hedw.) DeNot. Hylocomium splendens (Hedw.) B.S.G. Polytrichum commune Hedw. Polytrichum juniperinum Hedw. Polytrichum juniperinum var. alpestre B.S.G. Polytrichum piliferum Hedw. VASCULAR PLANTS POL YPODIACEAE . Woodsia ilvensis (L.) R. Br .......... ~ ............................. Rusty fern Dryopteris disjuncta (Ledeb.) C. V. Morton ........... Oak fern Dryopteris fragrans (L.) Schott .............. : ................... Fragrant cliff fern Cryptogramma crispa (L.) R. Br. var. acrostichoides (R. Br.) C. B. Clarke .............. Mountain parsley EQUISETACEAE Equisetum sylvaticum £ ....... : ........................ -............... Woodland horsetail Equisetum sylvaticum L. · var. multiramosum (Fern.) Wherry Equisetum fluviatile L. ............................................... Water horsetail Equisetum scirpoides Michx ....................................... Dwarf scouring rush .. 89 LYCOPODIACEAE Lycopodium annotinum L. var. pungens (La Pyl.) Desv .................................. Pungent stiff club-moss • Lycopodium obscurum L. .......................................... .Tree club-moss Lycopodium complanatum L. ..................................... Running club-moss PINACEAE Picea glauca (Moench) Voss ..................................... White spruce Picea mariana (Mill.) BSP ....................................... Black spruce Larix laricina (Du Roi) Koch ..................................... Tamarack Pinus banksiana Lamb ................................................ Jack pine Juniperus communis L. var. depressa Pursh ............. Ground juniper GRAMINEAE Festuca saximontana Rydb .......................................... Rocky mountain fescue Poa pratensis L. ........................................................... June grass Poa interior Rydb ........... ~ ........................................... .Inland bluegrass Poa palustris L. ............................................................. Fowl meadow grass Poa glauca Vahl ........................................................... Blue-green meadow grass Agropyron trachycaulum (Link) Malte ..................... Rough-stemmed grass Hordeum jubatum L .................................................... Squirrel-tail grass Deschampsia caespitosa (L.) Beauv .......................... Tufted hairgrass Calamagrostis purpurascens R. Br .............................. Purplish reed-bentgrass Calamagrostis canadensis (Michx.) Beauv ............. Bluejoint Agrostis scabra Will d. . ................................................ Hairgrass Alopecurus aequalis Sobol. ........................................ ,Water foxtail Beckmannia syzigachne (Steud.) Fern ...................... Slough-grass CYPERACEAE Eriophorum spissum Fern ............................................ Hare's-tail Eriophorum angustifolium Honck .............................. Narrow-leaved cotton grass Scirpus caespitosus L. var. callosus Bigel. ................. Callous bulrush Scirpus hudsonianus (Michx.) Fern .......................... Hudson Bay bulrush Carex foenea Will d ..................................................... Hay-like sedge Carex loliacea L. Car ex brunnescens (Pers.) Poir. . ................................ Brownish sedge Carex canescens L. ....................................................... Hoary sedge Carex aenea Fern .......................................................... Hay sedge Carex deflexa Hornem ................................................ .Deflexed sedge Car ex paupercula Michx .............................................. Bog sedge Carex media R. Br. Carex aquatilis Wahl. ... ' ................................................ Water sedge Carex rostrata Stokes JUNCACEAE ]uncus vaseyi Engelm. !uncus baltic us Will d .................................................... Wire rush Luzula multiflora (Retz.) Lej ...................................... Wood rush LILIACEAE Smilacina trifolia (L.) Desf ........................................ False Solomon's seal ORCHIDACEAE Spiranthes romanzoffiana Cham. & Schl. ................. Hooded ladies' tresses SALICACEAE Populus tremuloides Michx. . ...................................... Quaking aspen Populus balsamifera L. ................................................. Balsam poplar Salix glauca L. ............................................................... Grayleaf willow Salix myrtillifolia Anderss ............................................ Myrtle-leaved willow Salix pseudomonticola Ball ......................................... False mountain willow Salix pyrifolia Anderss. . .............................................. Balsam willow Salix bebbiana Sarg ...................................................... Long-beaked willow Salix planifolia Pursh ................................................ Flat-leafed willow 1 Salix arbusculoides Anderss. MYRICACEAE Myrica gale L. ............................................................... Sweet gale 90 BETULACEAE Betulapapyrifera Marsh ............................................... White birch Betula papyri/era Marsh var. humilis (Regel) Fern & Raup Betula glandulosa Michx ..................................... : ...... Dwarf birch Alnus crispa (Ait.) Pursh ............................................ Green alder Alnus tenuifolia Nutt .................................................... River alder SANTALACEAE Geocaulon lividum (Richards.) Fern ....................... .Northern comandra POLYGONACEAE "R-umex occidentalis S. Wats ....................................... Dock NYMPHAECEAE Nuphar variegatum Engelm ........................................ Bullhead lily RANUNCULACEAE Anemone patens L. ....................................................... Pasque flower Ranunculus lapponicus L. Ranunculus abortivus L. ............................................. Kidney leaf buttercup FUMARIACEAE Corydalis sempervirens (L.) Pers .............................. Pale corydalis CRUCIFERAE Draba nemOI"osa L. Lepidium bourgeauanum Thell .................................... Pepperwort SAXIFRAGACEAE Saxifraga tricuspidata Rottb. Ribes oxyacanthoides L. Ribes hudsonianum Richardson Ribes glandulosum Grauer ........................................... Skunk currant PARNASSIACEAE Parnassia palustris L. var. neogaea Fern .................... Grass of Parnassus ROSACEAE Amelanchier alnifolia Nutt .......................................... Saskatoon-berry Rubus idaeus L. var. aculeatissimus Regel & Tiling ......................... Raspberry Rubus chamaemorus L. ............................................... Cloudberry Rubus acaulis Michx .................................................... Dwarf raspberry Fragaria vesca L. ......................................................... Woodland strawberry Potentilla norvegica L. ................................................ .Norwegian cinquefoil Potentilla palustris (L.) Scop ...................................... Marsh cinquefoil Potentilla tridentata Ait. . ............................................ Three-toothed cinquefoil Geum perincisum Rydb ............................................... .Avens Rosa bourgeauiana Crep. . ............................................ Prickley rose Prunus pensylvanica L. f .............................................. Pin cherry EMPETRACEAE Empetrum nigrum L. var. hermaphroditum (Lange) Sorensen ............... Black crowberry ELAEAGNACEAE Shepherdia canadensis (L.) Nutt ................................ Soapberry ONAGRACEAE Epilobium angustifolium L. ......................................... Fireweed Epilobium glandulosum Lehm. var. adenocaulon (Haussk.) Fern .......................... Willow herb ARALIACEAE Aralia nudicaulis L. ..................................................... Wild sarsaparilla CORNACEAE Comus canadensis L. ................................................... Bunchberry PYROLACEAE Moneses uniflora (L.) A. Gray ................................. Wintergreen (one flowered) Pyrola secunda L. ......................................................... One-sided wintergreen Pyrola virens Schweigger Pyrola asarifolia Michx ................................................ Pink Pyrola .. 91 ERICACEAE Ledum groenlandicum Oeder ....................................... Common Labrador tea Ledum palustre L. var. decumbens Ait ...................... Northern Labrador tea Loiseleuria procumbens (L.) Desv ............................ Alpine azalea Kalmia polifolia Wang ................................................ Pale laurel Andromeda polifolia L. .......................... : .................... Bog rosemary Chamaedaphne calyculata (L.) Moench ................... Leather leaf Arctostaphylos uva-ursi (L.) Spreng ......................... Common bearberry Vaccinium uliginosum L. .............................. , .............. Bog bilberry Vaccinium myrtilloides Michx ................................... .Velvet-leaf blueberry Vaccinium vitis-idaea L. var. minus Lodd .................. Mountain cranberry Vaccinium oxycoccus L. ............................................... Small cranberry GENTIANACEAE Menyanthes trifoliata L. ........................................... Three-leaved buckbean SCROPHULARIACEAE Pedicularis labradorica Wirsing ······:····························Lousewort LENTIBULARIACEAE Pinguicula villosa L. . .................................................... Butterwort RUBIACEAE Galium trifidum L. ....................................................... Three-cleft bedstraw CAPRIFOLIACEAE Viburnum edule (Michx.) Raf .................................... Squashberry Linnaea borealis L. var. americana (Forbes) Rehd . .Twinflower CAMPANULACEAE Campanula rotundifolia L. ........................................... Harebell COMPOSITAE Solidago spathulata DC ................................................ Goldenrod Aster laevis L. ............................................................... Smooth aster Aster ciliolatus Lind!. .................................................. .Aster Achillea sibirica Ledeb ................................................ Siberian yarrow Achillea lanulosa Nutt .................................................. Woolly yarrow Matricaria matricarioides (Less.) Porter ................... Wild chamomile Petasites palmatus (Ait.) A. Gray ............................. Palmate sweet coltsfoot Petasites vitifolius Greene ........................................... Grape-leaved sweet coltsfoot Petasites sagittatus (Pursh) A. Gray ......................... Arrow-shaped sweet coltsfoot Senecio pauperculus Micl}.x. var. flavovirens (Rydb.) Boivin ......................... Poor groundsel Taraxacum dumentorum Greene ................................. Dandelion Taraxacum officinale Weber ...................................... .Common dandelion Hieracium scabriusculum Schw .................................. Hawkweed Appendix B CHECKLIST OF VERTEBRATE FAUNA ON THE BARREN-GROUND CARIBOU WINTER RANGE OF NORTHERN SASKATCHEWAN Class OSTEICHTHYES (nomenclature based on Scott, 1958) Salvelinus namaycush (Walbaum) ............................. Lake trout Esox lucius (Linnaeus) ............................................... Northern pike Stizostedion vitreum vitreum (Mitchill) ......... , ........... Walleye Thymallus arcticus (Pallas) ......................................... Arctic grayling Catostomus sp. . ............................................................ Sucker Coregonus clupeaformis (Mitchill) .... · ....................... Lake whitefish 92 Class AVES (nomenclature based on American Ornithologists' Union-Check-list, 1957) Gavia immer (Brunnich) ............................................. Common loon Branta canadensis (Linnaeus) ..................................... Canada goose Anas platyrhynchos Linnaeus ..................................... Mallard Anas acuta Linnaeus ............................................... : ..... Pintail Anas carolinensis Gmelin .............................................. Green-winged teal Aythya affinis (Eyton) ............................................... Lesser scaup Bucephala clangula (Linnaeus) ................................. Common goldeneye Bucephala albeola (Linnaeus) ................................... Bufflehead Melanitta perspicillata (Linnaeus) ............................. Surf scoter Mergus merganser Linnaeus ......................................... Common merganser Accipiter gentilis (Linnaeus) ....................................... Goshawk Buteo jamaicensis (Gmelin) ....................................... Red-tailed hawk Haliaeetus leucocephalus (Linnaeus) ......................... Bald eagle Pandion haliaetus (Linnaeus) ...............•..................... Osprey Falco columbarius Linnaeus ....................................... Pigeon hawk Falco sparverius Linnaeus ........................................... Sparrow hawk Canachites canadensis (Linnaeus) ............................. Spruce grouse Lagopus lagopus (Linnaeus) ....................................... Willow ptarmigan Pedioecetes phasianellus (Linnaeus) ....................... :.Sharp-tailed grouse Actitis macularia (Linnaeus) ....................................... Spotted sandpiper Tringa solitaria Wilson ...................... ~ .......................... Solitary sandpiper Totanus flavipes (Gmelin) ........................................... Lesser yellowlegs Larus philadelphia (Ord) ........................................... Bonaparte's gull Sterna hirundo Linnaeus ............................................. Common tern Chordeiles minor (Forster) ......................................... Common nighthawk Megaceryle alcyon (Linnaeus) ................................... Belted kingfisher Colaptes auratus (Linnaeus) ...................................... .Yellow-shafted flicker Picoides arctic us (Swainson) ....................................... Black-backed three-toed woodpecker Hirundo rustica Linnaeus ........................ ; .................... Bam swallow Perisoreus canadensis (Linnaeus) ............................... Gray jay . Corvus corax Linnaeus ................................................. Common raven Parus atricapillus Linnaeus ......................................... Black-capped chickadee Parus hudsonicus Forster ............................................. Boreal chickadee Turdus migratorius Linnaeus ..................................... Robin Hylocichla gutta/a (Pallas) ......................................... Hermit thmsh Regulus calendula (Linnaeus) .................................. Ruby-crowned kinglet Dendroica petechia (Linnaeus) ................................ Yellow warbler Dendroica coronata (Linnaeus) ................................. Myrtle warbler Seiurus noveboracensis (Gmelin) ............................... Northern waterthrush Euphagus carolinus (Muller) .......... ; .......................... Rusty blackbird Loxia leucoptera Gmelin .............................................. White-winged crossbill Junco hyemalis (Linnaeus) ........................................ .Slate-colored junco Spizella passerina (Bechstein) .................................... Chipping sparrow Zonotrichia leucophrys (Forster) ............................... White-crowned sparrow Melospiza melodia (Wilson) ...................................... Song sparrow Class MAMMALIA (nomenclature based primarily on Beck, 1958) Euarctos americanus Pallas ......................................... Black bear Canis lupus Linnaeus ................................................... Gray wolf (tracks seen) Maries americana (Turton) ......................................... Marten Lepus americanus (Erxleben) ..................................... Snowshoe hare .. Tamiasciurus hudsonicus (Erxleben) ......................... Red squirrel Castor canadensis Kuhl. ............................................... Beaver (house and dam seen) Peromyscus maniculatus (Wagner) .......................... .Deer mouse (trapped) Alces alces (Linnaeus) ............................................... Moose Rangifer tarandus groenlandicus (Linnaeus) ............ Barren-ground caribou 93 PLOT RECORD Total Total Compilation field Species 1 2 3 4 5 6 7 8 9 10 Wt. lbs./ %Dry Dry lbs. acre PUF FW FW FW FW FW FW FW FW FW FW grms. Wt. Wt. UF Grasses: ., ...... "" I-w w I '. en w a.. ci () :::::1 2 > I ci w 0 a: I-2 ..... w ci 0 .c en a: 2 ~ a.. w $; CD ..... rn cu LL. CD t: Cl CD C"CS ·;: _J _J .c ... CD Cl w en I-<( _J [i: Forbs.: Shrubs: $; w 2 I- <( <( Cl ~ <( I- 2 en <( w I () I- Lichens: -·-., -'-''<'" I C!J -. w $; (.) cD .~ ...: a. 0 ·>, "C >. I-CD !:: > cD 0, eli CD ... 1d CD 0. :J CD ... 0. en Cl > <( <t: Plot Totals COMMENTS 1. Range Conditions: ............................................................................................. . 2. Current Utilization: ........................................................................................... . 3. Vigor of Major Forage Species: ..................................................................... . 4. Biotic Influence: ................................................................................................. . 5. Timber: Age ....................................................................................................... . Method of determination ................................................................... . Density ............................................................................................... . Composition ......................................................................................... . 6. Topography: ....................................................................................................... . 7. Site Productivity: ............................................................................................... . 8. Soil: ..................................................................................................................... . 9. Slope: ................................................................................................................... . 1 0. Remarks: ............................................................................................................. . 95 Appendix D FORAGE PRODUCTIVITY IN WHITE BIRCH AND BLACK SPRUCE FORESTS IN VARIOUS AGE CLASSES TABLE 22 Air-dry forage in recently burned forests 1 to 10 years of age Locations Higginson Grove Oblate McKeever Little Faraud Marchant Lake Lake Lake Lake Lake Lake Grams per 80 plots X 10 Grass & grass-like plants Agrostis scabra .........................•... 650 ----2262 C alamagrostis canadensis ........... 1350 1800 48 5646 229 450 Poa glauca ..................................... 750 ---- - Poa interior ....................... · ............ - - - - -- Carex aenea .................................... -36 176 547 2600 325 Carex brunnescens ....................... --350 --- Carex canescens ........................... ---438 -- Carex def/exa ................................. -1196 1845 193 246 - Carex joenea ................................. 850 ----- Carex spp. .................. .................. 350 - - - 70 - Equisetum sylvaticum ................. - - 187 1718 - - 3950 3032 2606 8542 3145 3037 Herbs Epilobium angustijolium ............. 14950 7400 5894 7395 13350 10943 Corydalis sempervirens ............... 150 -20 420 740 80 Epilobium glandulosum ............. ----30 - Petasites palmatus .. .................... ---T* -- 15100 7400 5914 7815 14120 11023 Shrubs High value Vaccinium vitis-idaea var. minu 4232 3066 819 836 336 442 4232 3066 819 836 336 442 Moderate value Salix spp ................. ~ ..................... 200 • -350 5150 2925 1400 200 -350 5150 2925 1400 Low value Alnus crispa ................................. -336 3045 2373 -- Andromeda polijo/ia ..................... -88 50 --23 Arctostaphylos uva-ursi ............... -48 28 --630 Ledum groenlandicum ................. 5432 1956 374 4642 462 598 Average Dodge productivity Lake per class in Ibs. - 7228 - 26 2366 - - 832 - - 751 11203 63 6640 300 -- 6940 122 676 676 18 45 45 18 2543 -- 1560 ·---------~------::-:;'-·.,. --··--::-;---. _, _____ ·-,. .... , . --:----"·--------·--·-- Ribes glandulosum ....................... ---60 45 -765 Rubus chamaemorus ................... -46 -253 -76 68 Rubus idaeus var. acu/eatissimus. 247 --1104 836 23 768 Vacciniurn myrtilloides ..... --3894 -48 -- Vaccinium uliginosum .... ............ -299 644 -48 -- 5679 2773 8035 8432 1439 1350 5704 60 Total shrub weight ........... (10111) (5839) (9204) (14418) (4700) (3192) (6425) (96) Lichens High value } Cladonia a/pestris C/adonia amaurocraea 74 364 30 --210 T Cladonia mitis C ladonia uncia/is Cladonia rangiferina .......... ........ -17 ----- 74 381 30 --210 T 1 Moderate value Cetraria nivalis ....... ...................... -75 T ---- Peltigera canina "' ··················-···· -140 30 --720 T Stereocaulon spp .. ....................... -62 99 --60 T -277 129 --780 T 2 Low value Cetraria·crispa C ladonia a/pica/a Cladonia botrytes Cladonia cariosa C ladonia cocci/era 355 130 T --390 T Cladonia cornu/a Cladonia cristatella Cladonia deformis Cladonia pyxidata Icmadophi/a ericetorum 355 130 T --390 T 2 Total lichen weight ................ (429) (788) (159) 0 0 (1380) T (5) Others Lycopodium annoti71um ............. 100 500 ----- Marchantia po/ymorpha ............. ---80 660 600 225 4 ', 100 500 -80 660 600 225 ''· Total weight ......................... 29690 17559 17883 30855 22625 19232 24793 Average pounds of forage per acre . 371 219 223 385 282 240 310 290 ~ *T= Trace TABLE 23 Air-dry forage in forests 11 to 30 years of age Location and age of forests Higginson Faraud Marchant Dodge Father Chipman Average Lake Lake Lake Lake Lake Lake Productivity 16 yrs. 19 yrs. 27 yrs. 13 yrs. 20 yrs. 15 yrs. per class Grams per 80 plots X 10 in lbs. Grass & grass-like plants Ca/amagrostis canadensis .................. ---300 660 1148 Gramineae-unidentified . . . . . . . . . . . . . . . . . . . . 525 161 50 --- Carex aenea ........................................ -- - 275 -140 Carex deflexa ······································ ---25 660 - Carex spp ............... ····························· 53 -225 -60 - 578 161 275 600 1380 1288 9 Herbs Epilobium angustijolium .................... 136 165 18 320 420 1197 Cornus canadensis ······························ -- - - 92 - Geocaulon lividum .............................. 14 - - 50 23 - 150 165 18 370 535 1197 5 Shrubs High value Vaccinium vitis-idaea var. minus ...... 10973 16000 26312 29588 11206 18299 10973 16000 26312 29588 11206 18299 234 Moderate value Empetrum nigrum ······························ -- - 90 -- Prunus pensylvanica ............................ ----68 801 Salix spp ............................................... 275 625 563 -1368 1059 275 625 563 90 1436 1860 10 Low value Ainus crispa ········································ 6762 -2183 -2589 - Arctostaphylos uva-ursi ...................... 912 275 -428 585 3300 Ledum groenlandicum ........................ 13901 5786 12844 11492 8379 3354 Linnaea borealis .................................. -----72 Ribes g/andulosum ······························ ----203 - Rubus idaeus var. aculeatissimus ...... -25 -23 46 566 Vaccinium myrtilloides ······················ -- - 430 790 - Vaccinium uliginosum ························ 621 - - 90 630 26 22196 6086 15027 12463 13222 7318 159 Total shrub weight ...................... (33444) (22711) (41902) (42141) (25864) (27477) (403) ' - Lichens High value C ladonia a/pestris } C/adonia amaurocraea 354 838 2100 701 880 529 C ladonia mitis C/adonia uncia/is Cladonia rangiferina .......................... T -30 88 - - 354 838 2130 789 880 529 12 Moderate value Cetraria nivalis .................................... 19 80 210 170 80 - Peltigera aphthosa .............................. 120 80 750 T -T Peltigera can ina .................................. 920 320 930 1322 760 220 Stereocau/on spp ................................. 105 240 840 597 120 - 1164 720 2730 2089 960 220 16 Low value Cetraria crispa Cladonia a/pica/a C ladonia bacillaris Cladonia botrytes Cladonia cariosa Cladonia cenotea C ladonia cocci/era 1354 4480 3810 4040 3880 4900 Cladonia cornuta C ladonia cristatella Cladonia de/armis Cladonia gracilis Cladonia pyxidata C ladonia turgida 1354 4480 3810 4040 3880 4900 47 Total lichen weight ...................... (2872) (6038) (8670) (6918) (5720) (5649) (75) Total weight ................................ 37044 29075 50865 50029 33499 35611 Average pounds of forage per acre .......... 463 363 635 625 418 445 492 \0 \0 -0 0 Grass & grass-like plants Calamagrostis canadensis ······························ G ramineae-unidentified ..... ........................ Equisetum sy/vaticum .................................. Herbs Epilobium angiiSii/olium ... ........ ................ Geocau/on lividum ... ... ,. ········ . ................ Shrubs High value Vaccinium vitis-idaea var. minus .. ............. Moderate value Empetrum nigrum ........ .... .......... . ........... Salix spp. """ ........ ............. . ......... Low.value A'/nus crispa ...... ..... ........... . ... ............ Andromeda polifo/ia .. ..... ... ..... ..... . . . . . . . . . . . . .. Arctostaphylos uva-ursi . ...... ..... ..... . ....... Ledum groenlandicum .... .... ..... ..... ... .. ........ Ledum pa/ustre var. decumbens ... Rubus chamaemorus ...... .... .... ... . . . . . . . . . . Vaccinium myrtilloides ...... ..... . ...... Vaccinium uliginosum '"" ....... ............. ........ Total shrub weight ..... ....... .. .......... TABLE 24 Air-dry forage in forests 31 to 50 years of age Location and age of forests Offset Faraud Father Chipman Average Lake Lake Lake Lake productivity 39 yrs. 32 yrs. 31 yrs. 50 yrs. per class Grams per 80 plots X 10 in lbs. 72 -60 30 -125 -- 18 --- 90 125 60 30 1 28 18 -- 1840 420 23 - 1868 438 23 -7 13258 28872 30602 19633 13258 28872 30602 19633 289 336 -135 - 450 625 1008 - 786 625 1143 -8 --1560 1328 80 --- 478 200 1756 - 3254 10186 9620 1508 94 --- -25 -- 1254 --- 2530 118 68 - 7690 10529 13004 2836 106 (21734) (40026) (44749) (22469) (403) -0 - ~ Lichens High value C/adonia alpestris } Cladonia arnaurocraea Cladonia mitis C/adonia uncia/is C/adonia rangijerina . . . . . . . . . . . . . . . . . . Moderate value Cetraria nivalis . . . . . . . . . . . . . . . . . . . . . . . . ........ .. >>> >>> >> Peltigera aphthosa ......... ......... ...... ..... ....... Peltigera canina ············· Stereocaulon spp. ..... ............... ....... .... ......... Low value Cetraria crispa Cladonia a/pico/a C/adonia bacillaris Cladonia botrytes Cladonia cariosa Cladonia cenotea C/adonia cocci/era Cladonia cornu/a C/adonia crispata C/adonia crista/ella C/adonia deforrnis C/adonia gracilis Cladonia rnultiforrnis Cladonia pyxidata C/adonia turgida C/adonia verticil/ala Nephroma arcticurn Total lichen weight ..................... Total weight ........ ..... >>> ........... Average pounds of forage per acre ........... ........ " • ' > -' ' ·-' - 3127 3600 7505 4798 184 180 21 144 3311 3780 7526 4942 61 550 495 161 130 -1745 920 1280 851 3707 2714 1232 3664 4905 4116 1633 5065 10852 7911 4275 88 3096 3285 4692 2964 3096 3285 4692 2964 44 (11472) (17917) (20129) (12181) (193) 35164 58506 64961 34680 439 731 812 433 604 TABLE 25 Air-dry forage in forests 51 to 75 years of age Grass & grass-like plants Calamagrostis canadensis Gramineae-unidentified Herbs Geocaulon lividum .............................................. . Shrubs High value Vaccinium vitis-idaea var. minus ............................................................ . Moderate value Empetrum nigrum Salix spp ............. .. Low value """'· Alnus crispa ......................................................... .. Arctostaphylos uva-ursi ....................................... . Kalmia polifolia .................................................. . Ledum groenlandicum ......................................... . Vaccinium myrtilloides Vaccinium uliginosum Total shrub weight ....................................... . Location and age of forests Grove Lake Oblate Lake 70 yrs. 60 yrs. 75 75 20 20 22251 22251 3402 21 5965 9388 (31639) Grams per 80 plots x 10 90 90 320 320 13965 13965 126 300 426 840 5258 1464 2569 10131 (24522) Oblate Lake 65 yrs. T T 1820 1820 17934 17934 147 225 372 624 6952 696 759 9031 (27337) Average productivity per class in lbs. 9 226 3 119 (348) -----------1-..-.Y--• ' Lichens High value Cladonia alpestris } C/adonia amaurocraea C ladonia mitis 2766 6930 4635 Cladonia unCia/is Cladonia rangiferina ..... ........................................ 849 315 450 3615 7245 5085 66 Moderate value Cetraria nivalis ........ ············································· 205 900 810 Peltigera aphthosa .. ............ ................................ 420 1874 1575 Peltigera canina ......... ........... ................................ 300 10253 3285 Stereocaulon spp. ....... .......................................... 293 14850 9225 1218 27877 14895 183 Low value Cetraria crispa Cladonia alpicola Cladonia cariosa Cladonia carneola Cladonia cornuta C/adonia crispata 984 3581 3600 Cladonia cristatella C/adonia deformis Cladonia gracilis Cladonia pyxidata Nephroma arcticum 984 3581 3600 34 Total lichen-weight .................. .. .............. (5817) (38703) (23580) (283) Total weight ............. .................. ................. 37551 63635 52737 -Average pounds of forage per acre .......................... 469 795 659 641 0 w TABLE 26 Air-dry forage in forests 76 to 120 years of age Location and age of forests Grove S. McKeever N. McKeever Faraud Father Newnham Average Lake Lake Lake Lake Lake Lake productivity 115 yrs. 120 yrs. 110 yrs. 95 yrs. 115 yrs. 110 yrs. per class Grams per 80 plots x 10 in lbs. Grass & grass-like plants Ca/amagrostis canadensis ... ...... 50 ---120 130 G ramineae-unidentified 150 "'' 514 197 195 --...... ... Carex spp. .................................. ----300 - Equisetum sy/vaticum ................ -36 124 71 231 - 200 550 321 266 651 130 4 Herbs Geocaulon lividum .... .............. --- - 23 339 23 339 1 Shrubs High value V accinium vitis-idaea var. minus .............. ........ . ........ 25230 19677 29976 31425 32526 32022 25230 19677 29976 31425 32526 32022 356 Moderate· value Empetrum nigrum .. ............. ..... 115 -425 -1060 91 Salix spp. ....... ........... ·············· -75 -T T - 115 75 425 T 1060 91 4 Low value Alnus crispa .... ........................... 1554 2394 1710 1771 8658 . 42 Andromeda polifolia ......... - - 25 -46 - L?dum groen/andicum ...... .... 10274 6490 4994 6688 -6760 Ledum pa/ustre var. decumbens ............ ........... ... -88 198 - - - Rubus chamaemorus ..... ............ - - 425 -204 T Vaccinium myrtilloides .............. -----207 V accinium oxycoccus ....... ........ --25 -69 - V accinium uliginosum ........ 115 --T 68 - 11943 8972 7377 8459 9045 7009 110 Total shrub weight ..... '" (37288) (28724) (37778) (39884) (42631) (39122) (470) ' -- Lichens High value Cladonia alpestris } Cladonia amaurocraea 4074 10880 9632 7566 11247 12136 C ladonia mitis C ladonia uncia/is Cladonia rangiferina .................. 2915 10080 6944 4515 13668 4531 6989 20960 16576 12081 24915 16667 205 Moderate value Cetraria nivalis ............................ 565 1000 1248 880 925 475 Peltigera aphthosa ...................... 100 7640 2959 3000 4864 260 Peltigera canina . ........................ 280 4520 2899 7720 5852 4660 Stereocaulon spp. ...................... T 1560 1120 5920 836 660 945 14720 8226 17520 12477 6055 125 Low value Cetraria crispa ~ Cladonia alpicola Cladonia botrytes Cladon.ia cariosa Cladonia cameo/a Cladonia cenotea Cladonia cocci/era Cladonia cornuta Cladonia crispata >-1041 1680 1632 2640 1900 3325 Cladonia cristatella Cladonia deformis Cladonia gracilis Cladonia multiformis Cladonia pyxidata C ladonia turgida lcmadophila ericetorum Nephroma arcticum 1041 1680 1632 2640 1900 3325 25 Total lichen weight . ......... (8975) (37360) (26434) (32241) (39292) (26047) (355) Total weight ........................ 46463 66634 64533 72391 82597 65638 Average pounds of forage per acre .... 581 833 807 905 1032 820 830 -0 0\ Grass & grass-like plants Calamagrostis canadensis .......... Poa g/auca .................................. G ramineae-unidentified .......... Carex spp ..................................... Equisetum sylvaticum ................ Herbs Epilobium angustifo/ium .......... Comus canadensis ...................... Geocaulon lividum ···················· Shrubs High value V accinium vitis-idaea var. minus ................................ Moderate value Empetrum nigrum ................ ..... Salix spp ....................................... Low value Alnus crispa ................................ Andromeda po/ijo/ia .................. Ledum groen/andicum .............. Rubus chamaemorus .................. Vaccinium myrtilloides .............. V(Jpciniuin uliginosum ·············· Total shrub weight Lichens High value C/adonia a/pestris } C/adonia amaurocraea Cladonia mitis Cladonia uncia/is C/adonia rangiferina .................. TABLE 27 Air-dry forage in forests over 120 years of age Location and age of forests Higginson Offset Oblate Marchant Lake Lake Lake Lake 125 yrs. 150 yrs. 130 yrs. 155 yrs. Grams per 80 plots x 10 - - 36 75 164 - --- - 18 --- - 25 - --- 164 -54 100 --14 - 75 ----1240 300 - 75 1240 314 - 18570 20140 15897 31746 18570 20140 15897 31746 -189 1848 --275 600 - -464 2448 - 336 924 1785 1981 55 - - - 4364 2407 8624 7280 -- ---484 552 --2208 2404 - 4755 6023 13365 9261 (23325) (26627) (31710) (41007) 15118 6372 7305 7647 10004 3772 667 7650 25122 10144 7972 15297 Dodge Chipman Average Lake Lake productivity 170 yrs. 135 yrs. per class in lbs. 75 600 - ---- - 20 - 95 600 2 - ----- --3 34476 39672 34476 39672 334 - - -- --6 4276 315 - - 11752 5408 40 -- - -- 16068 5723 115 (50544) (45395) (455) 18983 16130 18327 14497 37310 30627 264 -0 -.1 - Moderate value Cetraria nivalis ............................ Peltigera aphthosa ....... ...... ....... Pe/tigera canina } Peltigera malacea Peltigera pulverulenta Stereocaulon spp ........... ..... ....... Low value Cetraria crispa ..., C/adonia a/pica/a C/adonia bacil/aris C/adonia botrytes C/adonia cariosa C/adonia cenotea Cladonia cocci/era Cladonia cristate/la Cladonia de/armis C ladonia gracilis C/adonia pyxidata C/adonia turgida C ladonia verticillata lcmadophila ericetorum Nephroma arcticum .................. Total lichen weight ............ Others Dryopteris fragrans .... .............. Total weight ........................ Average pounds of air-dry forage per acre ............................ ~ 972 4250 520 69 1677 4807 409 42672 3578 51798 1978 2350 -1426 1978 3776 (30678) (65718) --- -- 54242 93585 678 1170 ·-·---- 1000 456 820 1100 2139 960 533 5134 3805 2820 492 4131 5233 99 697 1292 12177 4335 2542 11657. 179 4372 1401 3321 3872 --41 - 4372 1401 3362 3872 39 (24521) (21033) (43214) (46156) (482) ---20 ---20 T 56599 62140 93853 92171 707 776 1173 1152 942 -0 00 Appendix E FORAGE PRODUCTIVITY IN JACK PINE FORESTS OF VARIOUS AGES TABLE 28 Air-dry forage in six jack pine forests Grass & grass-like plants Agrostis scabra ..................................................... . Calamagrostis canadensis ................................... . Gramineae-unidentified ..................................... . Carex aenea ........................................................... . Carex defiexa ......................................................... . Newnham Lake 5 yrs. 1520 180 Stony Rapids 15 yrs. 225 T 100 Carex ...................................................................... 175 Carex spp. . . .............. ......... ..................................... 250 Location and ages Black Newnham Lake Lake 16 yrs. 35 yrs. Grams per 80 plots x 10 Black Lake 43 yrs. Grove Lake 65 yrs. Equisetum sylvaticum .......................................... 720 r---p17mo~o----+-~1~4~7on---+----------+----------+----------+---------- Herbs Achillea lanulosa ................................................. . Achillea sibirica .................................................. .. Epilobium angustijolium ..................................... . 2603 Corn us· canadensis ................................................ . Fraga ria vesca ................ . Geocaulon lividum ............................................. .. Parnassia palustris ............................................. .. Pinguicula villosa . . . . . . . . . . ................................... . Pyrola spp ............... .. 180 45 3744 995 92 225 T 23 19 55 280 Taraxacum officinale . ............................. T r---~26N0~3-----r--~5~30~4,---+-----~74.----r----------+-----------~--~2~80~--- Shrubs .,, High value Vaccinium vitis idaea var. minus ........................ 1898 2800 7685 24766 5481 27557 r---«18m9o8----+-~2~8n.oo----+---~7~68"'5~--+-~2~47~6~6----+---~54~8~1----+--;27~5~57~--- Moderate value Empetrum nigrum ........... .. Salix spp. Low value Alnus crispa ............. .. Andromeda polifolia .. Arctostaphylos ziva-ursi ...................................... .. 1659 1659 63 T 3761 15933 18819 336 336 6216 126 Ledum groenlandicum ......................... . Linnaea borealis ... . ........................ . Potent ilia tridentata ............................................ . Rosa bourgeauiana . . ................................ . Ribes g/andulosum .............................................. .. Rubus acaulis ................................ .. Rubus chamaemorus ........................................... . Rubus idaeus var. aculeatissimus ....................... . V accinium myrtilloides ....................................... . V accinium uliginosum ....................................... .. 125 69 23 360 4092 92 136 23 409 T T 2448 891 46 6300 2457 2852 T 2997 1861 5775 Viburnum edule ............... .................................... 113 Total shrub weight Lichens High value C/adonia alpestris C/adonia amaurocraea C/adonia mitis Cladonia uncia/is } ~--~5~7~7----+-~11~1~37~--+-~2~3~17~0~--+-~2~4~12~8----+-~1~49~8~8----+---1~9~8~7---- (2475) (15596) (30855) (48894) (20469) (29880) 380 2496 4350 15899 2308 Cladonia rangiferina .......................................... ·f----------ll--~:-::---l----::-:-::-::----l----:-:-:7~2::__--+---:-:::3:-6-;-:3:---l--=-3-73=:.:3:--- 380 2496 4422 16262 2641 Moderate value Cetraria nivalis .... .................................. 208 638 749 Pe/tigera aphthosa ................................................ 4680 26 520 Peltigera can ina .... ... ......... ...... ............................ 195 6200 T 26 2000 Stereocaulon spp. ..... ............................................ 200 78 70 3264 ~--~1~975----+-~11~0~80~--+-----~T~--+-~~33-8----+---~7~0~8----+---6~5~3~3---- Low value Cetraria crispa Cetraria islandica Cladonia alpicola C/adonia botrytes C/adonia coccijera Cladonia crispata C/adonia deformis C/adonia ·gracilis C/adonia multiformis C/adonia pyxidata Cladonia turgida Others 'II Total lichen weight Marchantia polymorpha Total weight ................................................ . Average weight in lbs. of forage per acre ............. .. (195) 18 18 6991 87 4800 4800 (16260) 38630 482 4386 4386 (6882) 37811 473 9726 9726 (14486) 63380 792 5235 5235 (22205) 42674 533 1231 1231 (10405) 40565 507 WILDLIFE MANAGEMENT BULLETINS SERIES 1 -Mammals * 1 The mammals of Waterton Lakes National Park. A. W. F. Banfield. April, 1950. * 2 Natural history and economic im- portance of the muskrat in the Athabasca-Peace Delta. W. A. Fuller. March, 1951. * 3 The mammals of Elk Island Na- tional Park, Alberta, Canada. J. D. Soper. November, 1951. * 4 Populations and movements of the Saskatchewan timber wolf (Canis lupus knightii) in Prince Albert National Park, Saskatchewan, 1947 to 1951. A. W. F. Banfield. No- vember, 1951. * 5 The mammals of Prince Albert National Park, Saskatchewan, Can- ada. J. D. Soper. June, 1952. * 6 Surveys of Elk and Other Wildlife in Riding Mountain National Park, Manitoba, 1950-51 and 1952. D. G. Colis. December, 1952. * 7 The mammals of Riding Mountain National Park, Manitoba, Canada. J. D. Soper. December, 1952. 8 The northwestern muskrat of the Mackenzie Delta, Northwest Ter- ritories, 1947-48. W. E. Stevens. 1953. 9 A preliminary study of the musk- oxen of Fosheim Peninsula, Elles- mere Island, Northwest Territories. J. S. Tener. 1954. : *lOA and B Preliminary i~vestigation of the barren-ground !=aribou. (2 vols.). A. W. F. Banfi¢ld. 1954. 11 Wolf control operations, Wood Buffalo National Park. 1951-52. William Fuller. 1955. 12 Continued barren-ground caribou studies. John P. Kelsall. 1957. 13 Range studies in Banff National Park, 1953. Robert Webb. 1957. 14 Preliminary investi!Zation of the Atlantic walrus (Odobenus ros- marus rosmarus). Alan G. Lough- rey. 1959. 15 Co-operative studies of barren- ground caribou, 1957-58. John P. Kelsall. 1960. *16 The biology and management of the bison of Wood Buffalo National Park. William A. Fuller. 1961. *17 The mammals of Manitoba. J. D. Soper. 1961. 18 Effects of forest fires on the winter ran!Ze of barren-ground caribou in northern Saskatchewan. George W. Scotter. 1964. 110 SERIES 2 -Birds * 1 A study of the bird populations in the apple orchards of the Annapo- lis Valley, Nova Scotia. J. P. Kel- sall. April, 1950. * 2 Waterfowl and related investiga- tions in the Peace-Athabasca Delta region of Alberta. J. D. Soper. May, 1951. * 3 The birds of Elk Island National Park, Alberta, Canada. J. D. Soper. February, 1952. 4 The birds of Prince Albert National Park, Saskatchewan. J. D. Soper. June, 1952. 5 The economic status of the herring gulls of the Grand Manan Archi- pelago, New Brunswick. D. H. Pimlott. June, 1952. 6 The birds of Riding Mountain Na- tional Park, Manitoba, Canada. J. D. Soper. December, 1953. * 7 Waterfowl and other ornithological investigations in Yukon Territory, Canada, 1950. J. D. Soper. Sep- tember, 1954. 8 Birds of Jasper National Park, Al- berta, Canada. I. MeT. Cowan. June, 1955. 9 The american goldeneye in central New Brunswick. Brian C. Carter. 1958. SERIES 3 -Fish * 1 Prince Albert National Park creel census analysis, season 1948. V. E. F. Solman. May, 1950. * 2 Limnological investigation of Fundy (New Brunswick) National Park, 1948. V. E. F. Solman. June, 1950. 3 Limnological investigations in Cape Breton Highlands National Park, Nova Scotia, 1947. V. E. F. Sol- man. 1951. Reprinted November, 1954. 4 Investigation of the spawnin!Z of northern pike in Prince Albert Na- tional Park, 1953. F. H. Schultz. August, 1955. 5 Investigation of lake trout and common whitefish in Wpterton Lakes, Waterton National· Park. .T. P. Cuerrier and F. H. Schultz. January, 1957. * 0 ut of print. HOW DOES THE CANADIAN WILDLIFE SERVICE FIT INTO THE NATIONAL WILDLIFE PICTURE? The Canadian Wildlife Service car- ries out both wildlife research and management. As a division of the National Parks Branch, Department of Northern Affairs and National Resour- ces, it is charged with the task of carry- ing out federal responsibilities with respect to wildlife, a renewable re- source of ever-increasing importance to the national welfare and economy. Each province has control over the natural resources within its boundaries, including wildlife. However, because Canada signed the Migratory Birds Treaty with the United States in 1916, there is a federal responsibility for the management and protection of migra- tory birds. The Canadian Wildlife Service administers the Act for the federal government. In practice, Fed- eral and Provincial Governments co- operate in all matters concerning mi- gratory birds. The Canadian Wildlife Service studies migratory birds through- out Canada and conducts scientific research into other wildlife problems in the Northwest Territories, the Yukon Territory and Canada's National Parks; it also co-operates with the adminis- trative agencies concerned when wild- life management programs indicated by research are instituted. The Wildlife Service staff includes mammalogists, ornithologists, limnolo- gists, pathologists, and a biometrician. A LE ROLE DU SERVICE CANA- DIEN DE LA FAUNE SUR LE PLAN NATIONAL Le Service canadien de la faune s'occupe tout autant de recherche sur la faune que de gestion. Etant rattache a la Direction des pares nationaux du ministere du Nord canadien et des Ressources nationales, il represente le gouvernement federal dans tout ce qui a trait a la faune, ressource renouvelable d'une importance sans cesse croissante pour la prosperite et l'economiedu pays. Chaque province regit les ressources naturelles qui se trouvent dans son territoire, y compris la faune. Nean- moins, en raison du Traite concernant les oiseaux migrateurs que le Canada a conclu avec les Etats-Unis en 1916, la gestion et la protection des oiseaux rnigrateurs est du ressort federal. Et c'est le Service canadien de la faune qui s'occupe, au nom du gouvernement federal, de faire observer la Loi sur la Convention concernant les oiseaux mi- grateurs. En pratique, les gouverne- ments federal et provinciaux collabo- rent en cette matiere. Le Service canadien de la faune poursuit 1' etude des oiseaux migrateurs dans le pays tout entier et effectue des recherches scientifiques ayant trait a d'autres ques- tions de faune dans les Territoires du Nord-Ouest, au Yukon et daus les pares nationaux; i1 collabore aussi avec les organismes administratifs inte- resses a !'execution de travaux de gestion dont des recherches ant etabli l'opportunite. Le Service canadien de la faune a a son service des mammalogistes, des ornithologistes, des lirnnologistes, des pathologistes et un biometriste. 111 105° Northwest Territories Study sites were located near the lakes indicated in solid black. Al NATIONAL PARKS BRANCH • DEPARTMENT OF NORTHERN AFFAIRS AND NATIONAL RESOURCES.