HomeMy WebLinkAboutSynposium on pink salmon 1962PHILIP GILHOUSEN
International Pacific Salmon Fisheries Commission
New Westminster, B.C.
Marine Factors
Affecting the Survival of
Fraser River Pink Salmon
THE INTERNATIONAL Pacific Salmon Fisheries Commission has studied two cyclic runs
of Fraser River pink salmon (Oncorhynchus gorbuscha). Although our experience with
pink salmon is not far advanced, we have been able to borrow many useful ideas from
long experience with sockeye (Oncorhynchus nerka). The following discussion will re-
late some of the facts and concepts we have assembled concerning factors acting in the
marine environment to affect pink salmon survival.
Management of Fraser River pink salmon has a twofold purpose; maintenance or
expansion of the runs and division of the catch between Canada and the United States.
Regulation of the fishery is important to the Salmon Commission because it determines
both division of catch and amount and nature of the escapement. Adequate regulations
cannot be divised unless a reliable forecast of survival is available. Knowledge of factors
controlling survival are therefore of prime importance to our management program. Be-
cause measurement of freshwater survival appears to provide a poor index of adult pink
salmon return, survival during the marine phase of pink salmon life history is being
studied.
This spring, the first study of the early marine life of Fraser River pink salmon was
undertaken. Sampling of the downstream migration in the Fraser River mouth confirmed
the time of saltwater entry of pink salmon fry inferred from measurement of emergence
curves in the spawning streams. It appears that the bulk of the fry enter salt water in
April with a range from March to May. This rather restricted period of saltwater entry
must be connected with survival or else pink salmon would never have been selected
toward this specialization.
Sampling of the population of young Fraser River pink salmon in coastal waters
was carried out this spring and summer on an exploratory level. Beach seine and purse
seine hauls were made in several areas adjacent to the mouth of the Fraser River.
Sampling was carried out in the "Gulf Islands" from Valdes Island to Saturna Island,
105
Symposium on Pink Salmon
in the San Juan Islands, at Point Roberts, and in the outer end of Burrard Inlet near
Point Grey (Figure 1.) . Pink salmon young were taken at most stations, and young
salmon, probably including pinks, were seen along almost every shore visited.
Young pink salmon were taken from April until August, when the sampling was
terminated. The appearance of very young fry along the island shores suggests rapid
dispersal from the Fraser River mouth. This is consistent with what is known concern-
ing the movement of Fraser River outflow in Georgia Strait. At least during the period
of spring freshet, from April to July, most of the river outflow is rapidly dissipated
past the islands of southern Georgia Strait and thence through Juan de Fuca Strait.
A portion of Fraser River effiuent moves northward along the east shore of Georgia
Strait. No investigation was made concerning the movement of pink salmon fry to the
north because of limited facilities.
Fraser River pink salmon fry, like those observed in other areas, spend a considerable
period of their early saltwater life in the littoral zone. Very likely this zone provides
106
FIGURE 1.
AREAS ADJACENT TO THE MOUTH OF THE FRASER RIVER WHERE YOUNG PINK SALMON
WERE CAPTURED IN THE SPRING AND SUMMER OF 1960.
Marine Factors Affecting the Survival of Fraser River Pink Salmon
them with both a food supply and shelter from their enemies. Preliminary examinations
of stomach contents shows that much if not all of their food is littoral in origin.
Comparisons have been made of the size of young pink salmon taken along the
shores with beach seines and those taken farther offshore with purse seines. The smaller
fish appear to stay closer to shore than the larger young. This edging away from shore
as the young grow is probably part of the general movement away from the land and
to the open ocean. Presumably, young pink salmon must stay in the shelter of the shore
until they reach sufficient size to venture to the open water.
Several investigators have concluded that conditions occurring during the early marine
life of pink salmon are exceedingly important to overall survival. Mr. Vernon's exami-
nation of environmental factors (1958) showed a useful relationship between seawater
temperature and salinity in the lower portion of Georgia Strait in spring and summer,
and subsequent pink salmon catches in the next year. The best single factor for pre-
dicting the return of Fraser River pink salmon appears to be the mean April to August
seawater temperature from Departure Bay, a point about 35 miles from the mouth of
the Fraser River (Figure 1). Although other factors, such as salinity, were found to
have a partial relationship to survival none approached the usefulness of the inverse
relationship with seawater temperature. Many of the factors studied were partially inter-
dependent, making it difficult to determine basic causes.
Seawater temperature could affect young pink salmon directly, but if the relationship
is in fact valid, it more likely acts through the food supply or predator distribution, or
through the distribution of young pink salmon in relation to these factors. We feel
that possibly hot weather and warm water along shore cause young pink salmon to
stay farther offshore where predators take a higher toll than in years of cool weather.
We have not yet investigated such predation but there is a long list of possible preda-
tors. The theory of variable predation is strengthened by the recent finding in South-
eastern Alaska of herring feeding on young pink salmon, especially since there are
large herring populations in Georgia Strait.
The relation of pink salmon catch to conditions early in marine life appears to act
semi-independently of escapement and therefore possibly of fry production in fresh
water. Apparently conditions for survival in the marine environment have been so
variable that variations in fry abundance have had a secondary effect on total survival.
Records of extremely large runs of Fraser River pink salmon in early years (Rounsefell
and Kelez, 1938) presents the possibility of obtaining, by proper management of !f<y
production, much larger returns than are currently being obtained for any given level
of marine conditions.
Young pink salmon apparently leave inshore waters in midsummer and move to the
open sea. We do not have direct evidence as to what areas they inhabit in the year
spent in the Pacific Ocean. The migration routes followed on the spawning migration
suggest a wide distribution both north and south of the Fraser River. During the Fraser
River pink salmon runs of odd years, salmon trollers have taken pink salmon at least
as far south as Northern California (Figure 2). Along the Oregon and Washington
coasts, a definite northward movement of adult pink salmon has been detected. A
similar southward movement of pink salmon has been noted from the Queen Charlotte
Islands toward Juan de Fuca Strait.
A considerable portion of Fraser River pink salmon are known to approach the
Fraser River via Johnstone Strait (Figure 2). A complex migration of this type poses
a problem in regulating a pink salmon run. A fishery exists in Johnstone Strait as well
as along the southern migration route. Because the efficiencies of the two fisheries are
107
Symposium on Pink Salmon
.. . Clio
QUEEN 01 iQ
CHARLOTTE ~ ~
" '\' '~i:l
FRASER RIVER
____ C_A_N_A_D_A _____ _
U.S, A.
i
t
N
J
t
RIVER
t
FIGURE 2.
MIGRATION ROUTES OF PINK SALMON IN THE OPEN OCEAN BOUND FOR SPAWNING
GROUNDS IN OR NEAR THE FRASER RIVER.
not exactly known, one is never sure just what proportion of the escapement is coming
from each route.
Fraser River pink salmon have been divided into two overlapping segments, one early
and one late in migration. At present, ther{' is no way to distinguish between fish from
the two segments until they separate when approaching the spawning grounds. Regula-
tion of the two groups in the fishery must be based on the timing of previous year's
runs whereas sockeye races may for practical purposes be separated by scale pattern
variations noted during the course of fishing.
108
Marine Factors Affecting the Survival of Fraser River Pink Salmon
A feature of the pink salmon spawning migration worth mentioning is the delay in
migration before river entry. Ward (1958) demonstrated a delay of about a week and
a half off the mouth of the Fraser River for the major (early run) segment of the
1957 Fraser River pink salmon migration. This was confirmed by the results of tagging
experiments carried out in 1959. Also, in 1959, a delay of at least this length could
be demonstrated for the late run pink salmon.
The delay in migration of some salmon runs off the mouth of their native river
offers several problems to salmon management. One of these is the problem of causing
variation in time of spawning by selective regulations in the fishery. Retention of
chronological order of individuals in a salmon migration has been demonstrated for
both sockeye and pink salmon. What happens if a salmon migration stops for several
days? Does the run maintain the same chronological order after the delay as it had
before the delay in migration? Or does the run rearrange itself in a random fashion?
The results of recent tagging experiments on Fraser River pink salmon indicate that
the same chronological order is in fact maintained throughout the migration despite
a delay off the Fraser River mouth of almost two weeks. The nature of the spawning
population can therefore be controlled by selective fishing regulations applied before
a delay.
The consequences of altering the natural timing of spawning to make it earlier or
later are not obvious. However, one must reflect upon the restricted spawning period
that nature has produced in unit salmon runs. Also the existence of fry survival rates
which vary with spawning time has been reported by Mr. Merrel in a previous paper
of this symposium.
Fishing regulations have been designed considering the nature of the spawning
populations. Because the Fraser River pink salmon run is composed of at least two
independent, overlapping segments, the Salmon Commission has tried to maintain a
uniform fishing pressure throughout the temporal extent of these segments or r.,:tces.
Thus the pattern of spawning will be little changed from what would have occurred
had there been no fishery. The only variation from this principle is the technique of
selective protection of the peak of a race in which the average time of spawning will
be little changed from that of an unfished run.
LITERATURE CITED
MERRELL, T. R., 1962. Freshwater survival of pink salmon at Sashin Creek, Alaska. Symposium on
Pink Salmon, Univ. Brit. Columbia, H. R. MacMillan Lectures in Fisheries.
ROUNSEFELL, G. A., and G. B. KELEZ. 1938. The salmon and salmon fisheries of Swiftsure Bank,
Puget Sound, and the Fraser River. U.S. Bur. Fish., Bull. 49 (27): 693-823.
VERNON, E. H. 1958. An examination of factors affecting the abundance of pink salmon in the
Fraser River. Internat. Pacific Salmon Fish. Comm., Prog. Rept. New Westminster, B.C., Canada.
WARD, F. J. 1959. Character of the migration of pink salmon to the Fraser River spawning grounds
in 1957. lnternat. Pacific Salmon Fish. Comm., Bull. 10. New Westminster, B.C., Canada.
DISCUSSION
MR. MANZER: You made reference to the sizes of pinks along the Gulf Islands. They were
smaller along the beaches and increased in size further offshore. Were these
samples taken about the same time?
MR. GILHOUSEN: I would like to say in that respect that I didn't do the work. The work was done
mostly by Mr. Verhoeven and Mr. Vernon. I think Mr. Verhoeven could answer
than better than I could.
MR. VERHOEVEN: One comparison we have made was from fishing at San Juan Island. We had a
beach seine sample and a purse seine sampie taken at the same time. The fish
in the purse seine sample were much larger than the largest fish in the beach
seine sample. Later on, when we were still able to get fish by purse seine, we
could no longer observe nor were we able to catch them with the beach seine.
109
Symposium on Pink Salmon
DR. KOO: My question is in regard to the migration routes of the pink salmon as you in-
dicated on the map. I might have missed some of your points, but I was wonder-
ing just how you an;ived at these migration routes of the pink salmon northward
from the California coast and southward from the Queen Charlotte Islands?
MR. GILHOUSEN: Coming from the south, the Fraser River pink salmon run is the only run of any
size, so it seems logical that there would be little but Fraser River pink salmon
that would be caught in numbers by salmon trollers south of the Juan de Fuca
Strait. However, to the north there are other pink salmon runs, and this com-
plicates the matter. The nearby non-Fraser runs in the odd numbered years,
when the large Fraser River pink salmon is on, appears to be considerably smal-
ler. Moreover the catch by the troll fleet is so much larger than in even years
that we infer that the catch is largely Fraser River pink salmon even as far north
as the Queen Charlotte Islands.
Also, there was mention made yesterday, I believe, of one pink salmon tagged
off the islands of southeastern Alaska that turned up in or near the Fraser River.
I don't know whether it was a Fraser River or Washington State pink salmon,
but anyway it does show that pink salmon can migrate from that area.
DR. KOO: Does the Commission have any plans of proving these migration routes by tag-
ging or other studies ?
MR. GILHOUSEN: Not that I know of.
MR. HIRSCHORN: How did you show in your tagging that the delay did not affect chronological
order?
MR. GILHOUSEN: We used tags applied in salt water in an area far enough away from the mouth
of the Fraser River that they would not be in the zone of delay. We compared
the time of tagging with the time of recovery as dead fish on the spawning
grounds. If you know something about the nature of spawning in salmon, there
is usually a fairly uniform period between the time of spawPing and the time of
death, so that the time of death would indicate the time of spawning. We found
a very good correlation between the time of tagging and the time of spawning
as inferred from the time the dead fish were recovered, and our dead recovery
was quite considerable. It wasn't just a spot effort; it was an every day careful
examination on the spawning grounds.
MR. SHERIDAN: I don't think, you mentioned this, !Jut do you think it is possible that the low
temperatures in the estuary would depress the urge or the ability of the small
pink salmon to feed, regardless of whether there was food available for them or
not?
MR. GILHOUSEN: We have no idea of that. The only thing I can say in that regard is reference to
Dr. Ricker's statement that possibly in southeastern Alaska you are working in
the lower range of temperature tolerance of the young salmon in coastal areas,
and we are working at the upper end of tolerance in some way.
DR. HOURSTON: You mentioned the possible theory of warm water driving the small salmon
offshore where they would be more susceptible to predation. I was wondering on
what basis you would consider that they would be more susceptible to predation
offshore. Surely there are major sources of predation inshore. One factor you
mentioned was the herring. Except for the resident population, the stock of
herring in the Gulf at the time is not too large and generally their food sources
are primarily organisms smaller than young salmon, although they certainly will
feed on the larger type organisms such as small salmon or small herring on oc-
casion. I wouldn't consider that herring would be a major source of influencing
survival of young salmon. Have you anything in mind besides them?
MR. GILHOUSEN: No, this was just a possibility we discussed. We haven't carried on any detailed
observations on the herring. I have heard they tend to stay a little further offshore
than salmon do.
My own feelings are that temperature does not have any direct effect on these
salmon as far as mortality goes. I can't see that it could act directly, but must
act somehow through the food or Jack of it, or through competitors. Beyond
that, we can't go at this time.
MR. VERNON: I would like to mention in addition, since I was involved in some of this work,
that we were rather impressed with the lack of predation in shallow areas. We
have no information on deep water for comparison, but the fish we found in
shallow water did not prey on pink salmon.
DR. MCHUGH: This differential distribution, inshore, offshore, according to size is not an un-
usual phenomenon at all. It is very common, for example, in the herring-like
110
Marine Factors Affecting the Survival of Fraser River Pink Salmon
MR. HIRSCHORN:
DR. THOMPSON:
MR. GILHOUSEN:
MR. VERHOEVEN:
MR. WICKETT:
DR. TULLY:
MR. GILHOUSEN:
VOICE·'?-
DR. TULLY:
VOICE:
DR. TULLY:
MR. GILHOUSEN:
DR. TULLY:
fishes in general and a good many estuary fishes on the east coast have similar
habits. So really, it seems to me very reasonable to assume that predation would
be more serious offshore than in the inshore waters because they would come in
contact with larger individuals of the same species which would be likely to eat
the small salmon.
I was thinking back on some earlier work I did on young herring, and it de-
pends a lot, on where the young salmon are found inshore. If they ar.e found
in areas where you are more likely to get sea bass or cod, such as around
wharves, and that sort of thing, you have a tremendous source of predators which
will feed on young fish of any kind when they are available.
In just spot examinations, I have opened some of these fish for stomach counts
and found up to 50 small fish which were recently taken by these fish, mixtures
of young salmon and herring.
A point I would like to bring out: If I understand it correctly, there are colonies
of pink salmon spawning in many streams on Puget Sound beyond the Fraser
River, and I have personal recollection of fi~h spawning in northern California.
Your evidence of movement north would have to be pretty strong if there isn't
a possibility that those small colonies would not explain the occasional catch of
pink salmon to the south of the Straits.
I am not familiar with the details of the catches made by the trollers, but I as-
sume they have been of sufficient proportions to eliminate most of these local
streams and, also, they appear to occur only in the odd years.
In regard to this question of evidence for the dispersal of pink salmon both north
and south we have some isolated instances, and they do not necessarily pertain
only to Fraser fish. They might be Puget Sound fish, or they might be fish going
to areas in southern B.C. But of pink salmon that were artificially propagated
and marked at Hood's Canal in the State of Washington, one was recently re-
ported taken off Oregon, which would show a dispersion southward.
In regards to northern areas, I remember in 1957 that one of the Fisheries Re-
search Institute's marine tags, was picked up in the Vedder River. I personally
picked up one in Spuzzum Creek. It had been put on at Noyes Island off Prince
of Wales Island. Of course, these are just isolated bits of information.
There are some other isolated reports as Pritchard's returns of marked fish pre-
sumably marked in the Queen Charlottes which were recovered on the Fraser.
This is giving you a reverse twist. They were marked as fry in the Queen Char-
lottes and recovered as adults in the Fraser.
I would like to ask the speaker in that part of Puget Sound between Los Angeles
and Kodiak, how long-
( Laughter)
-how long are the pink salmon found in the coastal waters, what time do they
first appear in that troll fishery?
I am not familiar with the details. I assume that it (appearance of pinks in the
troll fishery) would be just through the summer (of the spawning migration).
July, I would guess.
They enter the coastal waters in July, approximately?
Yes.
And what time do they enter the ocean going on the seaward migration? I
am not talking about the Strait Juan de Fuca. I mean getting out past, say,
Swiftsure, or thereabouts.
We have no direct evidence, but presumably it is in the summer or early fall at
the latest.
I have really been trying to get some information on this because is affects the
time consideration when these beasts are exposed to an ocean environment.
111
H. R. MacMILLAN LECTURES IN
FISHERIES
§ymposium on
Pink Salmon
A SYMPOSIUM HELD AT
THE UNIVERSITY OF BRITISH COLUMBIA
OCTOBER 13 to 15, 1960
Edited by N. J. Wilimovsky
INSTITUTE OF FISHERIES
THE UNIVERSITY OF /BRITISH COLUMBIA
VANCOUVER '-----
1962