Loading...
HomeMy WebLinkAboutEffects on arctic grayling of prolonged exposure to yukon placer mining 1984Effects on Arctic Grayling (Thymallus arcticus} of Prolonged Exposure to Yukon Placer Mining Sediment: A Laboratory Study D. J. Mcleay, G. L. Ennis, I. K. Birtwell, and G. F. Hartman Department of Fisheries and Oceans Habitat Management Division Field Services Branch 1090 West Pender Street Vancouver, British Columbia V6E 2P1 January _1984 Canadian Technical Report of Fisheries and Aquatic s ·ciences No. 1241 · Fis heries P~ches 8fl d Oceans et Oceans Canada Canadian Technical Report of Fisheries and Aquatic Sciences Technical reports contain scientific and technical information that contributes to existing knowledge but which is not normally appropriate for primary literature. Technical reports are directed primarily toward a worldwide audience and have an international distribution. No restriction is placed on subject matter and the series reflects the broad interests and policies of the Department of Fisheries and Oceans, namely, fisheries and aquatic sciences. Technical reports may be cited as full publications. The correct citation appears above the abstract of each report. Each report is abstracted in Aquatic Sciences and Fisheries Abstracts and indexed in the Department's annual index to scientific and technical publications. Numbers 1-456 in this series were issued as Technical Reports of the Fisheries Research Board of Canada. Numbers 457-714 were issued as Department of the Environment, Fisheries and Marine Service, Research and Development Directorate Technical Reports. Numbers 715-924 were issued as Department of Fisheries and the Environment, Fisheries and Marine Service Technical Reports. The current series name was changed with report number 925. Technical reports are produced regionally but are numbered nationally. Requests for individual reports will be filled by the issuing establishment listed on the front cover and title page. Out-of-stock reports will be supplied for a fee by commercial agents. Rapport technique canadien des sciences halieutiques et aquatiques Les rapports techftiques contiennent des renseignements scientifiques et techni- ques qui constituent une contribution aux connaissances actuelles, mais qui ne sont pas normalement appropries pour Ia publication dans un journal scientifique. Les rapports techniques sont destines essentiellement a un public international et ils sont distribues a cet echelon. II n'y a aucune restriction quant au sujet; de fait, Ia serie reflete Ia vaste gamme des inten~ts et des politiques du ministere des Peches et des Oceans, c'est-a-dire les sciences halieutiques et aquatiques. Les rapports techniques peuvent etre cites comme des publications completes. Le titre exact para it au-dessus du resume de chaque rapport. Les rapports techniques sont resumes dans Ia revue Resumes des sciences aquatiques et halieutiques, et ils sont -classes dans !'index annual des publications scientifiques et techniques du Ministere. Les numeros 1 a 456 de cette serie ont ete publies a titre de rapports techniques de !'Office des recherches sur les pecheries du Canada. Les numeros 457 a 714 sont parus a titre de rapports techniques de Ia Direction generale de Ia recherche et du developpe- ment, Service des peches et de Ia mer, ministere de l'Environnement. Les numeros 715 a 924 ont ete publies a titre de rapports techniques du Service des peches et de Ia mer, ministere des Peches et de l'Environnement. Le nom actuel de Ia serie a ete etabli lors de Ia parution du numero 925. Les rapports techniques sont produits a !'echelon regional, mais numerotes a !'echelon national. Les demandes de rapports seront satisfaites par l'etablissement auteur dont le nom figun.!_sur Ia couverture et Ia page du titre. Les rapports epuises seront fournis contre retribution par des agents commerciaux. Canadian Technical Report or Fisheries and Aquatic Sciences No. 1241 Yukon River Basin Study Fisheries Project Report No. 9 January 1984 EFFECTS ON ARCTIC GRAYLING (Thymallus arcticus) OF PROLONGED EXPOSURE TO YUKON PLACER MINING SEDIMENT: A LABORATORY STUDY by D. J. McLeay1, G •. L. Ennis2a, I. K. Birtwe112b and G. F. Hartman2c 1D. McLeay & Associates Ltd., Suite 300, 1497 Marine Drive, West Vancouver, B.C. V7T 1B8 2Fisheries and Ocean Canada a) Habitat Management Division, Field Services Branch, 1090 West Pender Street, Vancouver, B.C. V6E 2P1 b) Salmon Habitat Section, Fisheries Research Branch, West Vancouver Laboratory, 4160 Marine Drive, West Vancouver, B.C. V7V 1N6 c) Salmon Habitat Section, Fisheries Research Branch, Pacific Biological Station, Nanaimo, B.C. V9R 2P1 -J.J. - (c)MJ.mster of Supply and SerVJ.ces Canada 19ti4 Cat. No. Fs 97-6/1241 ISSN U7U6-6457 [ [ [ [ [ [ [ r L [ c r -:' l r - L -iv - TABLE OF CONTENTS PREFACE iii TABLE OF CONTENTS iv LIST OF TABLES • • vi LIST OF FIGURES .• viii ABSTRACT . . . . ~ . . . . . . RESUME • INTRODUCTION MATERIALS AND METHODS TEST FISH Fish collection Fish rearing • • • TEST SEDIMENT • • • • • Sediment collection . . . . . . . . . . . . .. . . Sediment preparation and analyses EXPERIMENTAL • • • • • • • • • Test apparatus • • Treatment of fish Test strengths of sediment • • • • • Water quality monitoring . • ••• Fish growth • • • • • • • • • . Fish behaviour • • • • • • • • • • • • • • • Fish condition . . . . . . • . . . . . . ~ . Fish performance • • • • • • • • • • • '~ • • • • Statistical analyses • • • • • RESULTS • • • • • • • • • • • SEDIMENT CHARACTERISTICS AND DISPERSAL WATER QUALITY • • • • • FISH SURVIVAL AND GROWTH FISH BEHAVIOUR • • • • • Distribution in streams Feeding response trials CONDITION OF FISH • • • • • • • • 0 • • • • • • General Fish length and condition factor Biological characteristics • • • PERFORMANCE OF FISH • • • • • • • • • Tolerance to reference Respiration • • • • • Temperature tolerance toxicant X xii 1 2 2 2 2 3 3 3 4 4 5 6 7 7 10 10 10 11 12 12 13 14 15 15 16 17 17 18 18 19 19 19 20 -iii - PREFACE This study, along with other work on short-term exposures of Arctic grayling, including studies of fish food habits and distribution, was carried out to provide some initial information on the effects of placer mining·sediments on this species of fish. While this work indicates the nature of certain physiological and behavioural responses of Arctic grayling to suspended sediment, it is recognized that a longer term programme of more comprehensive studies on the effects of sediments on various stages in the life cycle of grayling and their habitat are desirable. Although we would urge caution in the interpretation and application of this first stage of research, it is hoped that the present findings together with those from our previous investigations with Arctic grayling, will provide information necessary for the sensitive and well-informed management of aquatic resources. The Yukon River Basin Study (a joint study by Canada, Yukon, and British Columbia of the waters and related resources of the Yukon Basin) and the Department of Fisheries and Oceans Canada (Field Services Branch and Fisheries Research Branch) funded this project. Statements made are those of the authors and not necessarily those of the Yukon River Basin Committee nor Parties to the Basin Agreement. The work was a co- operative undertaking by D. McLeay & Associates Ltd. and staff of the Department of Fisheries and Oceans. ;;; f~ [ [ [ [ [ l- [ r: L [ [ [ b [J [ E r , L r, L L [ [ [ [ [ [ [ r L .. [ lJ [ [ [ r~ l [ - v - DISCUSSION • • • • • • • • • ·• . • • • • • • • • • • • • SEDIMENT DISPERSAL/CONCENTRATION IN TEST STREAMS ••• FISH SURVIVAL AND GROWTH • • • • •. • • • • • • • • • • FISH DISTRIBUTION • • • • • • • • • • FEEDING BEHAVIOUR OF FISH • • • • • • • • • • • FISH CONDITION • • • • • • • • • • • • • • • FISH PERFORMANCE • • • • • • GENERAL • • • • • • • • • • • • ACKNOWLEDGEMENTS REFERENCES • . . . . . . . . . . . .. . . . . TABLES • FIGURES. APPENDIX 21 21 22 23 24 25 27 28 29 30 35 53 79 3 Table --- 1 2 3 -vi - LIST OF TABLES Particle size distribution for test sediment collected from a placer mine settling pond. Oxygen uptake rate, volatile ci.nd fixed residue for test sediment collected from a placer mine settling pond. Metal content for test sediment collected from a placer mine settling pond. 4 Effect of stream position on suspended sediment strength. 5 6 7 8 9 10 Summary of water quality characteristics in test streams during the 6-week period of exposure of underyearling Arctic grayling to differing strengths of suspended placer mining sediment. Weekly mortalities of underyearling Arctic grayling in test streams during prolonged exposure to differing strengths of placer mining sediment. Weekly weights for groups of underyearling Arctic gray- ling exposed for 6 weeks to differing strengths of sus- pended placer mining sediment. Percentage distribution of underyearling Arctic grayling in four equal portions of each test stream following ex- posure of fish to suspended placer mining sediment for 4 or 5 weeks. Effect of differing strengths of suspended placer mining sediment on the feeding response to surface drift (Drosophila melanogaster) for underyearling Arctic gray- ling held in test streams for 5 weeks. Effect of differing strengths of suspended placer mining sediment on the feeding response to surface drift (Drosophila melanogaster) for underyearling Arctic gray- ling held in test streams for 1 hour prior to testing. 11 Effect of differing strengths of suspended placer mining sediment on the feeding .response to sub~surface drift (Artemia salina) for underyearling Arctic grayling held in test streams for 6 weeks. [ ll LJ L [ [ [ [ [ f' L rc r [ [ [ [ [ c r L [ c [ E r L I " L Table 12 13 14 15 16 17 18 -vii - LIST OF TABLES (cont'~ ) Effect of differing strengths of suspended placer mJ.nJ.ng sediment on the feeding response to a benthic invertebrate ( tubificid worms) for underyearling Arctic grayling held in test streams for 5 weeks vs. 1 hour prior to testing. Length, weight, and condition factor of underyearling Arctic grayling following exposure to differing strengths of suspended placer mining sediment for 3 or 6 weeks. Biological characteristics determined for underyearling Arctic grayling following exposure to differing strengths of suspended placer mining sediment for 6 weeks. Acute lethal tolerance of underyearling Arctic grayling to the reference toxicant pentachlorophenol following exposure . to differing strengths of suspended placer mining sedimen't for 3 weeks. Acute lethal tolerance of underyearling grayling to the reference toxicant pentachlorophenol following exposure to differing strengths of suspended placer mining sediment for 6 weeks. Response of underyearling Arctic grayling to hypoxia fol- lowing exposure to differing strengths of suspended placer mining sediment for 6 weeks. Upper lethal temperature tolerance of underyearling Arctic grayling following exposure to differing strengths of suspended placer mining sediment for 6 weeks. Figure 1 2 3 4 5 6 7 8 9 10 -viii - LIST OF FIGURES Illustration of test streams showing reservoir barrels, barrel stirrers, peristaltic pumps for dispensing sediment suspensions, recycle pumps and air supply. Relationship of nonfiltrable residue (NFR) concentration of placer mining sediment added to barrel vs. suspended sediment strength within test streams. Illustration of daily fluctuations in concentration of nonfiltrable residue within each test stream throughout the 6-week exposure period. Illustration of daily fluctuations in turbidity within each test stream throughout the 6-week exposure period. Effect of suspended placer mining sediment on the growth (weekly wet weight gain) of underyearling Arctic gray- ling. Illustration of effect of differing strengths of suspended placer mining sediment on feeding response for underyearling Arctic grayling held in test streams for (a) 5 weeks or (b) 1 hour prior to testing. Illustration of effect of differing strengths of suspended placer m1n1ng sediment on time to consume groups of 10 benthic worms (tubificids) for underyearling Arctic grayling held in test streams for ,(1;1.) 5 weeks or (b) 1 hour prior to testing. Illustration of effect of d-iffering strengths of suspended placer m1n1ng sediment on time to consume groups of 10 sub-surface drift organisms (Artemia salina) for underyearling Arctic grayling held in test streams for 6 weeks prior to testing. Effect of 3-week exposure of underyearling Arctic gray- ling to suspended placer mining sediment on their acute lethal tolerance to the reference toxicant pentachloro- phenol. Effect of prolonged (6-week) exposure of underyearling Arctic grayling to suspended placer mining sediment on their acute lethal tolerance to the reference toxicant pentachlorophenol. [ [ [_, [ [ [ [ r-: t-_ j [ L J ' l~ [ [ [ [ [ r L 6 E r , L .~ L Figure 11 12 13 -ix. - LIST OF FIGURES (cont'd.) Effect of prolonged (6-week) exposure of underyearling Arctic grayling to suspended placer mining sediment on their tolerance to hypoxia in sealed jar bioassays. Effect of prolonged ( 6-week) exposure of underyearling Arctic grayling to suspended placer mining sediment on their time to death in sealed jar bioassays. Effect of prolonged ( 6-week) exposure of underyearling Arctic grayling to suspended placer mining sediment on their upper lethal temperature tolerance. -X - ABSTRACT Mcleay, D. J., G. L. Ennis, I. K. Birtwell, and G. F. Hartman. 1984. Effects on Arctic grayling (Thymallus arcticus) of prolonged exposure to Yukon placer mining sediment: a laboratory study. Canw Tech. Rep. Fish. Aquat. Sci. 1241: 96 p. The effects on underyearling Arctic grayling (Thymallus arcticus) of a 6-week exposure to differing strengths of suspended placer mining sediment was examined under controlled laboratory conditions during the summer of 1983. Groups of sixty grayling captured from a Yukon River tributary stream were transferred to eight test streams and acclimated to laboratory feed and water quality conditions. Thereafter, sediment collected from the downstream end of a Yukon placer mine settling pond was introduced continuously to six streams at a controlled rate in order to expose fish to suspended sediment concentrations of 100, 300 or 1000 mg·L-1 (two streams per treatment). Two control streams continued to receive clear ( nonfiltrable residue < 5IIig·L-1) freshwater. Fish in each stream were fed a measured ration (7% wt • day-1) of Biodiet, 4-5 times. daily, together with supplemental feeding of live zooplankton (Daphnia pulex). Water quality conditions for each stream, including temperature ( 15 ~ 10C), pH (6.6 ~ 0.1), conductivity (30 ~ 5 umho•cm-1), dissolved oxygen (9.4 ~ 0.2 mg·L-1), nonfiltrable residue and turbidity, were monitored daily. The survival of fish iri. each stream throughout the 6-week test period was high (87 -95%) and unaffected by the sediment suspensions. Fish growth, as monitored by weekly weighings of individual fish, was decreased slightly ( 6 -10% relative to control fish) but significantly by 100 and 300 mg·L-1, and more markedly impaired (33% relative to controls~ by 1000 mg·L-1. The linear distribution of grayling in each stream was unaffected by the lowest ( 100 mg·L-1) suspended sediment strength examined; however, the majority of fish held in each stream containing 300 or 1000 mg•t.""1 sedimen~ were displaced downstream throUghout the test period. Feeding response trials were conducted in each stream using live surface drift (adult fruit flies; Drosophila melanogaster), sub- surface drift (brine shrimp; Artemia salina) and benthic invertebrates ( tubificid worms). Times to detect and consume surface drift for naive fish (previously unexposed to sediment) or those held in test streams for 5 weeks increased progressively with increasing sediment strengths. All suspended sediment strengths examined increased the response times relative to those for control fish. For each respective concentration, naive fish were slower to respond to surface drift. The majority of naive fish held in 1000 mg·L-1 sediment failed to accept the surface or sub-surface food types offered. Feeding trials conducted with grayling offered brine shrimp or tubifex worms in each test stream after 5 or 6 weeks' sediment exposure indicated that the feeding activity of fish in 1000 mg·L-1 suspended sediment was impaired, whereas those reared in 100 or 300 mg·L-1 sediment responded to these sub-surface food types as quickly as control fish in clear water. [ [ [ [ [ r L [ [ [ [J p c [ L [ I . L [ [ [ [ [ [ [ r' L [ c 0 [ I ~ l -xi - The colouration of fish exposed to 300 or 1000 mg·L-1 suspended sediment was paler than that of controls or those held in 100 mg·L-1 sediment for 6 weeks. Otherwise, the appearance of all sediment exposed fish (including gross observations of fish gills) was indistinguishable from that of controls. Biological characteristics determined for fish groups sampled from each stream after 6 weeks' sediment exposure, in- cluding condition factor, body moisture content (%), blood hematocrit (%), blood leucocrit (%) and plasma glucose (mg%), were unchanged from control values for all sediment strengths examined. The performance of fish groups sampled from each laboratory stream upon completion of the 6-week exposure was examined using standardized acute lethal tolerance tests with the reference toxicant pentachloro- phenol, sealed jar bioassays (tolerance to hypoxia), and tests for upper lethal temperature tolerance. Both groups of fish chronically exposed to the two higher suspended sediment strengths examined (300 or 1000 mg·V·1) showed a decreased tolerance to this reference toxicant, and decreased times to death (increased oxygen uptake rates) in sealed jar bioassays. The ability of fish to withstand hypoxia or upper lethal temperature extremes was unaffected by the prolonged sediment exposures. It was concluded that, whereas chronic exposure of Arctic grayling to suspended sediment concentrations < 1000 mg·L-1 may not cause direct mortalities of fish or impair their respiratory capabilities, suspended sediment strengths above 100 mg·L-1 causes a number of serious sublethal effects including impaired feeding ability, reduced growth rates, down- stream displacement, decreased scope for activity and decreased resist- ance to other environmental stressors. The environmental relevance of these findings is discussed. -xii- RESU~ Mcleay, D. J., G. L. Ennis, I. K. Birtwell, and G. F. Hartman. 1984. Effects on Arctic grayling (Thymallus arcticus) of prolonged exposure to Yukon placer mining sediment: a laboratory study. Can. Tech. Rep. Fish. Aquat. Sci. 1241: 96 p. Les auteurs ont etudie !'incidence de differentes concentrations de sediments en suspension provenant d'une exploitation miniere alluviale sur des ombres arctiques (Thymallus arcticus) de moins d 1 un an. L'exposition a dure six semaines sous des conditions controlees en laboratoire pendant 1' ete de 1983. Des groupes de 60 ombres captures dans un tributaire du fleuve Yukon Ont ete transferes danS hui t COUrS d I eau experimentaUX et aCClimateS a la nourriture de laboratoire et a la qualite de l'eau. Des sedi111.ents recueillis a la sortie d 'un bassin de sedimentation d 'une exploitation alluviale du Yukon ont ete introduits continuellement dans six cours d'eau, a un taux controle, de fa9on a exposer les poissons a des concentrations.de sediments en suspension de 100, 300 et 1000 mg.L-1 (deux cours d'eau par traitement). Les deux aut res cours d' eau ont. continue -de recevoir de 1 'eau· douce claire (residu non filtrable 5 mg.L-1). Tous les poissons ont ete nourris de rations quantifiees (7% poids. jour -1) de Biodiet quatre a cinq fois par jour, en plus de zooplancton (Daphnia pulex) vivant. Tous les jours, on a surveille les facteurs qualitatifs de l'eau y compris la temperature (15 :t l°C), le pH (6,6 :1: 0,1), la conductivite (30 :1:5 umho.cm-1), !'oxygene dissous (9,4 :1: 0,2 mg.L-1), les residus non filtrables et la turbidite. La survie des poissons dans tous les cours d'eau a ete elevee (87-95%) pendant toute la periode de six semaines et n'a pas souffert des sediments en suspension. La croissance, controlee par la pesee hebdomadaire de chaque poisson, a baisse un peu (de 6 a 10% par rapport aux poissons temoins) mais de fa~on significative, aux concentrations 100 et 300 mg.L-1, et elle a nettement diminue (33% par rapport aux poissons temoins) a 1000 mg.L-1. La repartition lineaire des ombres dans chaq~e cours d'eau n'a pas ete alteree par la plus faible concentration de sedimen~s en suspension (100 mg.L-1); toutefois, la plupart des poissons peuplant les cours d 1 eau contenant 300 et 1000 mg.L-1 de sediments se sont diriges vers l'aval pendant toute la periode d'experience. Des essais sur la reaction a la presence d'aliments ont ete menes dans chaque cours d'eau a !'aide d'organismes vivants flottant a la surface (drosophiles adultes, Drosophila melanogaster) et sous la surface (artemias, Artemia salina) ainsi que d'invertebres benthiques (Tubificides). Le temps de detection et de consommation des proies de surface par les poissons a 1' etat naif (encore jamais exposes aux sediments) et par ceux gardes dans les cours d'eau experimentaux pendant cinq semaines a augmente progressivement en fonction des concentrations de sediments. Toutes les concentrations etudiees [ [ [ [ [ [ [ [ I' L f~ L [ [ [ [ [ [ [ [ [ n L [ [ L r : L -xiii- ont entratne une augmentation des temps de reaction par rapport a ceux des poissons temoins. A chaque concentration, les specimens a l'etat na~f etaient plus lents a reagir aux proies de surface. La plupart de ces poissons gardes a une concentration de 1000 mg.L-1 n'ont pas mange les p.roies flottant a la surface ou sous la surface. Les essais d'alimentation a !'aide d'artemias ou de tubifex, menes dans les cours d'eau experimentaux apres cinq OU Six SemaineS d I expositiOn a deS SedimentS, }lortent a CrOire que !'alimentation des poisson8 gardes a une concentration de 1000 mg.L-1 de sediments en suspension etait alteree tandis que ceux maintenues a des concentrations de 100 ou 300 mg.L-1 reagissaient aux p.roies p.resentes sous la surface aussi vite que les poissons temoins gardes en eau claire. Les poissons exposes a des concentrations de 100 et de 300 mg.L-1 de sediments en suspension etaient plus pales que les temoins ou les poissons gardes a une concentration de 100 mg.L-1 pendant six semaines. Pour le res te' tOUtefOiS' 1 I apparence de tOUS leS poiSSODS expoSeS a deS SedimentS (y compris !'observation superficielle des branchies) n'etait pas differente de celle des temoins. Les caracteres biologiques (facteur de condition, teneur en eau (%), hematocrite sanguin (%), leucocrite sanguin (%) et glucose plasmatique (mg%)) determines chez des groupes de poisson echantillonnes dans chaque cours d'eau apres six semaines d'exposition a des sediments etainent semblables aux valeurs temoins a toutes les concentrations de sediments etudiees. On a evalue la performance des groupes de poisson echantillonnes dans chaque cours d'eau experimental apres une exposition de six semaines, a !'aide de tests de la tolerance letale aigue avec le toxique etalon pentachlorophenol, de dosages biologiques en milieu ferme (tolerance a l'hypoxie) et de tests de tolerance de la temperature letale superieure. Les deux groupes de poisson exposes chroniquement aux deux plus hautes concentrations de sediments en suspension (300 et 1000 mg.L-1) ont accuse une tolerance moindre a ce toxique etalon et des temps inferieurs de mortalite (absorption accrue de !'oxygene) au cours des tests en milieu ferme. La capacite de resistance des poissons a l'hypoxie ou aux extr@mes de temperatures letales superieures n'etait pas affectee par !'exposition prolongee a des sediments. Selon les auteurs, m~me si !'exposition chronique de l'ombre arctique a des concentrations de sediments en suspension inferieures ou egales a 1000 mg.L-1 ne cause pas la mortalite directe des poissons ou n'amoindrit pas leurs capacites respiratoires, des concentrations superieures a 100 mg.L-1 entra1nent certains effets subletaux importants y compris une capaci te d' alimentation redui te, des taux de croissance inferieurs, un deplacement en aval, une capacite diminuee d'activite et une resistance moindre aux stress environnementaux. Les auteurs parlent aussi de !'importance environnementale de ces decouvertes. [ [ [ [ [ [ [ r L [ [ [ r' l r- L [ INTRODUCTION Recent field and laboratory studies conducted with underyearling Arctic grayling (Thymallus arcticus) demonstrated that brief ( ~ 4 days) exposure to elevated levels of suspended placer mining sediment, while not lethal, caused a number of sublethal effects including acute stress responses (McLeay et al. 1983). Additionally, reports from a number of field surveys within Yukon documented a reduction in numbers of Arctic grayling and other fish species for rece~v~ng waters downstream of placer mining activities (Mathers et al. 1981; Ennis et al. 1983; Birtwell et al. 1984). These findings suggest an impact of placer mining sediment suspensions on the fisheries resource;· however the nature and extent of effects of sediment strength and duration of exposure are not clearly understood at this time. The present investigation was undertaken to gain some under- standing concerning the effects on Arctic grayling caused by prolonged exposure to Yukon placer mining sediment. Although information is limited, reduced survival or impaired growth of salmonid fish species have been reported caused by their extended exposure to suspended sediment fines as low as 300 mg·L-1 (Herbert and Merkens 1961; Sigler 1981). · The effects of prolonged sediment exposure on fish performance, biochemical indices of fish condition, or behavioural responses have not been reported. However, the need for further knowledge regarding these and other possible effects caused by chronic exposure of fish to elevated levels of suspended sediment has been recently delineated (Noggle 1978; Anon. 1983). · · The strengths of suspended placer mining sediment selected for the present laboratory study (0, 100, 300 and 1000 mg·L-1 nonfiltrable residue) were chosen based on a number of considerations. Since the level of suspended sediment in certain placer-mined Yukon streams frequently remains elevated during summer months to values > 1000 mg·L-1 (Mathers et al. 1981), the impact of this elevation on the wellbeing of resident grayling fry or fingerlings rearing in these waters is of concern. Although the adverse effects towards grayling caused by chronic exposure to suspended sediment are unknown, suspended sediment strengths > 300 mg·L-1 have been reported to cause significant mortalities of salmonid fish if exposures are prolonged (Herbert and Merkens 1961), and strengths .?.. 100 mg·L-1 can cause reduced feeding activity and lower fish condition factors (Noggle 1978; Scullion and Edwards 1980). Following a review of (then) current literature, the European Inland Fisheries Advisory Commission (Anon. 1965) concluded "wate:r:-s normally containing from 80 to 400 ppm (mg·L-1) suspended solids are unlikely to support good freshwater fisheries", and "at best, only poor fisheries are likely to be - 2 - found in waters which nqrmally contain more than 400 mg·L-1 suspended solids." Discharge standards of 100 or 1000 mg·L-1 (depending on stream classification) have been recently proposed for Yukon placer mining operations (Anon. 1983). The study described in this report was designed to determine the effects of three replicate strengths of suspended placer mlnlng sediment on the feeding behaviour, growth, biological condition and performance capabilities of underyearling Arctic grayling held in artificial streams under controlled environmental conditions. Variables measured to assess fish condition and performance were based on those shown to be useful in previous assessments of fish exposed to suspended sediment or other environmental stressors (Noggle 1978; Wedemeyer and McLeay 1981; McLeay et al. 1983; Wedemeyer et al. 1983). MATERIALS AND METHODS TEST FISH Fish collection A population of approximately 3000 young-of-the-year Arctic grayling were collected by pole seine from a Yukon River tributary stream (Nares Creek; near Carcross, Yukon Territory) during June 1983. These fish, captured by pole seining, measured 2 - 4 em fork length. Creekwater temperature at the time of collection varied from 15 to 21oc. Upon capture, fish were placed in plastic "laundry" baskets lined with fibreglass mesh screen, covered with plastic sheeting and held in Nares Creek for up to 48 h until sufficient numbers were collected for shipment. At this time, groups of 200 -250 individuals were placed in separate plastic bags (creekwater with an oxygen atmosphere), packed with ice and shipped by air to Vancouver in twelve "Coleman" coolers. Fish rearing Grayling were transferred to the fish-culturing facilities at B. C. Research (Vancouver) upon receipt, and placed in an outdoor fibreglass hatchery trough. Water supply to this rearing trough was Vancouver City dechlorinated tap water. The water exchange rate was > 5 L·g-1 fish per day and fish-loading density did not exceed 1 .5 g·L-1 (Sprague 1973) throughout the period that grayling were reared in this trough. Fish were fed an excess ration of Biodiet No.1 size; Bioproducts Inc., Warrenton, Oregon) 8 ( < 0.6 mm crumble 10 times daily, [ [ [ [ [ c L [ L [ r~ L r L [ [ [ [ [ [ [ [ [ r L h c E r: L [ ---·-·-------~---------- - 3 - according to accepted hatchery practice (Leitritz and Lewis 1976). This diet was supplemented with daily feedings of live daphnia (Daphnia pulex) and weekly feedings of live brineshrimp (Artemia salina). Daphnia were reared outdoors in two shallow (15 em) circular (100 em dia) plastic pools. Water supply for culturing daphnia was local mountain creekwater, transported in 20-L plastic jerricans. The initial brood stock of daphnia was obtained from the B.C. Ministry of Environment water quality laboratory. Daphnia were fed twice-weekly rations of finely homogenized fresh spinach. Water was aerated con- tinuously and was renewed infrequently. The brine shrimp used for rearing fish and for feeding behavioural trials with test fish was purchased as required from a local distributor. The fish trough was siphoned daily to remove excess food and faeces. Dead or injured fish were removed upon observation. All fish selected for prolonged exposure to sediment were acclimated to these conditions for 3 weeks prior to their transfer to the test streams. TEST SEDIMENT Sediment collection A 275-kg sample of dry sediment was collected by Indian and Northern Affairs Canada personnel from a Yukon (Highet Creek) placer mine settling pond in June 1983. This sample was taken from a sur- ficial 5-cm layer of sediment within the downstream end of a de- watered settling pond. Preliminary screening of pond sediment with a 50 um mesh screen was undertaken to select the section of the pond containing the largest percentage of fines. The sediment was placed in ten (new) 25-L plastic pails with snap-on lids. This sample was shipped to Vancouver, whereupon it was mixed throughly and returned to the pails for storage ( 18 -200C) until required for testing. Sediment preparation and analyses Preliminary examination of the sample of settling pond sediment re-dispersed in freshwater ind~cated rapid re-settling of sediment particles. Initial trials with this sample stirred in water within the test apparatus used for the present study confirmed that sample suspensions with nonfiltrable residue (NFR) values of 100 -1000 mg·L-1 could not be achieved without reduction of particle size. Accordingly, all portions of the sediment sample used in the bioassays were pulverized prior to fish exposure. Quantities of sediment re- quired daily for the 6-week exposure study were oven-dried (500C) to - 4 - constant weight, and measured amounts (200 ml ":'250 g) ring-pulverized according to a procedure used previously for acute exposure studies with grayling and inorganic placer mining sediment (McLeay et al. 1983). A 250-g portion of untreated sediment and two 250-g portions of prepared (pulverized) sediment taken from separate plastic pails were analysed for particle size distribution. Each sample was wet-sieved, oven-dried ( 500C) and mechanically agitated for 10 min through a standard series of Tyler sieves. The percentage weight of sediment retained on each sieve was calculated (Anon. 1972). Two sub-samples of prepared sediment were analysed for each of the following characteristics: oxygen uptake rate, % volatile residue, % fixed residue, and concentration of inorganic constituents. The oxygen uptake rate of this sediment at 15oc was determined ac- cording to a procedure used previously with placer mining sediment (McLeay et al. 1983). Percentage volatile and fixed residue were determined according to Standard Methods (Anon. 1979, 1980). Major and trace inorganic constituents of the sediment were determined by plasma spectrographic analysis following sample digestion (Anon. 1979). EXPERIMENTAL Test apparatus The experimental set-up used for this study is illustrated in Figure 1. Basic apparatus consisted of eight test streams, situated side-by-side and constructed of 6-mm plexiglass sheeting. Each stream measured 210 X 13 X 20 em and was fitted with a removable screen partition at the mid-and down-stream positions (at 100 and 200 em from the head end), a vertical overflow stand-pipe at the downstream end and horizontal inflow/outflow plastic pipes at each end. The water (or test suspension of sediment) in each stream was pumped (Cole-Parmer impeller driven pumps) at 10 L·min-1 through 2-cm ID plastic tubing. This flow rate maintained an upstream riffle of fast moving water within the first third of the test stream, and a down- stream pool of slower-moving water within the latter stream portion. Oil-free compressed air was introduced continuously to the head-and mid-stream positions of each stream at a controlled rate. An emergency oxygen supply (compressed 02 cylinder and regulator with normally closed solenoid valve) was plumbed into the air supply line to ensure against the event of a power failure. Four 220-L capacity rigid polyethylene barrels were used as re- servoirs for the sediment suspensions. The sediment strength .prepared daily (using clear freshwater) in each of three barrels was stirred constantly ( Greey Lightnin motor at 1700 rpm with a stainless steel shaft and 8-cm dia impeller). One barrel contained clear freshwater [ [ [ [ [ [ [ r~ L [ - ~l b c b [ [ r . L [ [ [ [ [ L r L r L [ 0 I= b I , L I . I c Ll - 5 - only (water for control streams). Throughout the 6-week period of sediment exposure, the contents of each barrel were pumped continu- ously (Cole-Parmer Masterflex peristaltic pumps) to each of two streams at a controlled rate of 70 ml•min-1•stream-1. This rate pro~ vided a 95% molecular exchange of each test suspension (and of control water) within each stream every 24 h (Sprague 1973). All barrels, pumps, and streams were housed within a temperature- controlled room, regulated to provide a test temperature within each stream of 15 .:!: 1oc. Each stream was covered with fibreglass mesh screening to prevent fish escapements. The test apparatus was designed and positioned within the room to permit easy access to both ends of each stream for feeding, cleaning, and fish feeding behavioural trials. Lighting to each test stream was provided by four 40-W broad- spectrum "Vitalite" fluorescent tubes, equally spaced across the streams. These lights were regulated by timer to maintain a day/night sequence of 18-h L: 6-h D. Additionally, overhead incandescent 40-W bulbs, regulated by timer and 30-min automated rheostat control, were synchronized with the fluorescent lights in order to provide a 30-min period of variable light intensity at each dawn and dusk. The intensity of light at the surface of each test stream during daylight hours was 100.:!: 5 foot-candles (1076.:!: 54 lux). Treatment of fish Following a 3-week period for the acclimation of grayling to laboratory conditions of water and feed, 480 fish selected from the rearing trough for similar size (mean weight for individuals, 0.4 g) were placed by random selection into the eight test streams, 60 per stream. Wet weight of each fish was recorded. Each st~eam contained clear (nonfiltrable residue < 5 mg·L-1) freshwater only. This water (Vancouver City dechlorinated· tap water at 15 .:!: 10C) was renewed continuously by the inflow of fresh water to each stream at a rate .?,230 ml·min-1 (Appendix 1), providing a 95% exchange every 9 h or less (Sprague 1973). Fish in each stream were fed a pe-weighed ration of Biodiet 4 - 5 times daily during an initial 7-day acclimation period in freshwater and throughout the 6-week sediment exposure period thereafter. The (excess) ration provided was approximately 7% wet body weight per day (based on the mean weight of fish in each test stream as derived from weekly weighings of individual fish), according to the dry food ration recommended for young salmonid fingerlings (Leitritz and Lewis 1976). This ration was initially Biodiet No. 1 ( < 0.6 mm crumble size) only, but was changed to a 50:50 mixture of Biodiet Nos. 1 and 2 (0.6 -0.8 mm) arter 3 weeks and to Biodiet No. 2 only after 6 weeks. Additionally, fish were fed live daphnia twice daily. The daphnia were -concentrated ~n glass 'beakers and (approximately) equal quantities dispensed to each stream by pipeting. This supplemental - 6 - ration of live food comprised less than 10% (dry weight basis) of the total daily food offerings. All food offered (commercial and live) was dispersed evenly along the length of the stream. Excess food and fa~ces in each stream were removed daily by siphoning, and screens cleaned. Arty dead fish noted at this time were removed, weighed, and examined. Following a 7-day period for fish to acclimate to these streams, the freshwater supply to ecich stream was discontinued and individual fish were re-weighed. Pre-determined strengths of sediment suspen- sions were then metered continuously from the reservoirs into the test streams throughout the subsequent 6..:week test period. The nominal strength of suspended placer mining sediment in each stream to which grayling were exposed, as assigned by random choice, was as follows: Stream nos. 4 and Stream nos. 2 and Stream nos. 3 and Stream nos. 1 and Test strengths of sediment 8: 5: 6: 7: 0 mg·L-1 NFR (control streams); 100 mg·L-1 NFR; . 300 mg•L~1 NFR; and 1000 mg·L-1 NFR Prior to transferring fi::Jh to the test streams, a preliminary study was conducted using the test apparatus to ascertain the strengths of sediment required for addition to each barrel in order to achieve the desired .suspended .sediment s~rengths ( 0, 100, 300, or 1000 mg·L-1 NFR) within each stream. Pre-weighed strengths of pulverized placer mining sediment ranging from 300 to 5000 mg·L-1 were made up in each barrel (220-L volumes) using clear (NFR <5 mg·L-1) Vancouver City dechlorinated tap water at· 15oc.' Each suspension was pumped into a separate test stream at the desired flow rate (70 ml·min-1), and sampies taken from the head-(upstream) and mid-stream positions of the stream for nonfiltrable residue (NFR) analyses after 22· h of dis- pensing.· Based on the .results of this study, it was calculated that quantities of sediment required daily for preparing each 220-L volume were 120 g (100 mg·L-1 NFR in streams 2 and 5), 350 g (300 mg·L-1 NFR in streams 3 and 6), and 1140 g (1000 mg·L-1 NFR in streams 1 and 7). These quantities were used initially during the definitive study. However, based on nonfiltrable residue values determined for stream samples collected daily during the test period, sediment quantities added to each barrel were increased by 20% after 2 weeks' exposure. This quantity was again modified slightly at 4 weeks ( 10% reduction). Vancouver City dechlorinated tap water at 15:t. 1oc was used daily for preparing each test suspension (and as control water). [ [ [ [ [ [ r L r L [ [ [ [ [ [ [ [ [ I , L r, I = L - 7 - Water quality monitoring The freshwater supply used for rearing grayling and as the diluent/control water was analysed weekly throughout the duration of the study. Water quality characteristics determined (Anon. 1980) for each sample were as follows: pH, temperature (OC), dissolved oxygen (mg 02·L-1), conductance (umho·cm-1), alkalinity (mg CaC03·L-1), EDTA hardness (mg CaC03·L-1), and nonfiltrable residue (mg·L-1). The water quality in each test stream was monitored daily throughout the 7-day acclimation period and the subsequent 6-week exposure period. The following variables were measured mid-stream (mid-depth, mid-length): temperature (OC), dissolved oxygen (mg o2 -L-1), pH, conductance (umho·cm-l), nonfiltrable residue (mg·L-1) and turbidity (formazin turbidity units; FTU). Temperature was measured by thermometer to the nearest 0. 1 oc. Dissolved oxygen was determined using a portable oxygen meter (Delta Scientific Model No. 1010). Stream pH was measured using a portable pH meter (Metrohm Herisan Model No. E488). Water samples were collected daily from each stream by siphoning from the mid-stream position into clean plastic bottles. These samples were analysed subsequently for conductance, nonfiltrable residue and turbidity, using standardized methodologies (Anon. 1979, 1980). Samples with low turbidity values ( < 25 FTU) were analysed for turbidity using a ·Hach Model 2100A turbidity meter; whereas those with higher values were determined using a Jackson Turbidimeter (APHA, U.S. Geological Survey). The rate of. inflow of each test suspension (or control water) to each stream was measured (stopwatch, graduate cylinder) and recorded daily. Minor adjustments to pumping rates were made as required. On one occasion (13/08/83), water samples were taken concurrently from three positions (upstream, mid-and downstream) within each test stream. Each sample, ,collected by siphoning · at mid-depth, was analysed for nonfiltrable residue content in order to ascertain the consistency of suspended sediment strengths along the length of each stream. · Fish.growth The growth of grayling in each test stream was monitored weekly throughout the study. At 7-day intervals following their transfer to streams, all fish in each stream were netted and placed ·in separate 44-L clean glass aquaria. Each aquarium contained the water or sediment suspension strength to which fish were exposed in test streams. The dissolved oxygen content of each aquarium water supply was maintained at > 9 mg 02·L-1 by continuous aeration. Individual fish in the aquarium· were netted and placed on a top-pan balance (Oertling Model No. HC22) into a beaker of test water (weight tared to zero). The weight of each fish was recorded to the nearest 0.01 g. Care was taken during each weighing to prevent excess carry-over of water. - 8 - Each group of fish from each stream was weighed and returned to the stream within a 60-min period. During this time, each stream was cleaned thoroughly and refilled with the test suspension/control water. Any dead or missing (based on the previous week's count) fish were noted for each group, and weekly mortalities recorded. After 3 weeks' sediment exposure, ten fish were sampled randomly from each stream for assessment of their tolerance to the reference toxicant pentachlorophenol. The wet weight (g) and fork length (em) of each of these fish were measured upon termination of the bioassay. Lengths and weights of each grayling surviving exposure to differing strengths of placer mining sediment for 6 weeks were also determined following the completion at this time of each evaluation of fish con- dition/performance. Fish behaviour Due to the opacity. of sediment suspensions, observations of fish in test streams were restricted to fish movements (surfacing, response time) discerned during routine feeding. The position of fish in each stream could also be observed at this time. On two occasions (after 4 and 5 weeks' sediment exposure), each stream was partitioned with screens into four equal lengths, just prior to the removal of fish for weight determinations. The number of fish occupying each stream portion was determined in order to gain some information concerning their distribution. The effect of suspended sediment strength on feeding response times to live food organisms for grayling held in each test stream for 5 or 6 weeks was ascertained. Separate feeding response trials were conducted using surface drift food organisms (fruit flies; Drosophila melanogaster), sub-surface drift (brine shrimp; Artemia salina), or benthic food organisms (tubificid worms). Live adult fruit flies were obtained from the Department of Zoology (Genetics Laboratory), University of British Columbia for the feeding response trials with surface drift. For each trial, all fish in each test stream were moved to the upstream half, and a screen partition inserted to prevent their downstream movement. Three fish in each stream were netted randomly and placed in the downstream half. Following a 60-min period for these fish to adjust to this transfer, the three fish were herded slowly to the most downstream 10-cm section of the stream using a second soft-mesh screen. A fruit fly was placed on the stream surface at a point 60 em upstream of these fish, and the second screen removed (time 0). Time (seconds) for fish to consume the fly was measured (stopwatch) and recorded. Each test was ter- minated at 360 seconds (6 min) if flies were uneaten. ,- [ [ -[ [ b E L I" L I L.: [ [ [ [ [ [ [ [ r L [ E r: L [· • - 9 - This procedure was replicated 5 -9. times (depending on trial) using each group of three· fish. Three separate trials with surface drift were conducted, using different groups of three fish selected from and tested in each stream for each trial. Following these feeding response trials with grayling exposed to susp~nded sediment for 5 weeks, two trials (5 -7 replicates per trial) were undertaken in each test stream using naive grayling (those previously unexposed to suspended placer mining sediment) • All test fish in each stream were moved to" the upstream half, and retained by screen partition. Naive fish were netted from the outdoor rearing trough and placed in the downstream half of each test stream, three fish per stream. Fish were given a 60-min period to adjust to this transfer. Thereafter, these fish were moved slowly to the most down- stream 10-cm portion of the stream, and their feeding response to live fruit flies determined as before. Feeding response trials with grayling and live sub-surface drift (brine shrimp) or benthic invertebrates (tubifex worms) were performed in test streams using submersible baskets. Each basket, measuring 60 X 15 X 15 em, was constructed of white soft-mesh nylon cloth supported by a rigid framework ( 4 mm stainless steel wire). Baskets were de- signed to permit observation of the number of sub-surface food organisms consumed in test streams at fixed time intervals. The tubifex worms used in feeding trials were obtained locally from a retail store. For each trial, all fish in each test stream were moved to the upstream half and screen partitions inserted. Ten worms were distributed randomly along the length of the bottom of a basket, and the basket submersed in the downstream portion of a test stream. Three grayling, selected randomly from the group held up- stream, were netted and placed in the basket. The bottom of each basket was raised to just below the stream's surface at fixed time intervals of 1, 3, 5, 10, 15, 30, 45, and 60 min and the number of uneaten worms counted. Each observation was performed quickly (5 - 7 sec) and care was taken to ensure that fish were not struggling out of water at these times. For each test stream, three feeding trials with worms were conducted in this manner, using different groups of three fish for each trial. Additionally, one feeding trial with tubifex worms was carried out in each stream using naive fish selected from the outdoor rearing tank. These fish were transferred to the pawn- stream half of each stream (3 fish per stream) and held for 1 h prior to placing them in baskets. The procedure for testing the feeding response of naive grayling with tubifex worms was identi~al to that used for fish held in the test streams for 5 weeks. Three feeding response trials with live brine shrimp and stream grayling were conducted in each stream after 6 weeks' exposure of test fish to sediment suspensions. For each test, ten brine shrimp were placed randomly in each stream basket, and three fish introduced. Test procedures for conducting these trials were identical to those described for the tests with worms. The feeding response of naive grayling in test streams was not examined using brine shrimp. -10 - Fish condition Following 6 weeks' exposure to sediment suspensions, ten grayling were sampled from each test stream for assessment of fish condition. Individual fish were netted, damp-dried, and measured for length (em) and wet weight (g). The caudal peduncle was severed and blood col- lected in a narrow-bore (0.5 mm ID) heparinized microhematocrit tube (Sherwood Industries Ltd., St. Louis). Fish carcasses were weighed (wet weight) and transferred to a 105oc oven until dried to constant weight. Body moisture content was determined thereafter. Autopsies of each group of ten fish were completed within 30 min. All blood samples were centrifuged (12500 rpm; 3 min). upon collection. Hematocrit and leucocrit ·values were measured according to procedures described previously (McLeay and Gordon 1977; McLeay et al. 1983). Plasma portions remaining following centrifugation were stored ( -200C) until analysed for glucose content (Beckman Glucose Analyser 2). The condition factor of each fish was calculated (based on fish fork length and wet weight). Fish condition factors were also determined for all fish sampled from test streams for assessments of fish performance after 3 and 6 weeks' exposure to placer mining sediment. Fish performance The acute lethal tolerance of test fish to the reference toxicant pentachlorophenol (Davis and Hoos 1975; McLeay et al. 1983) was determined following their exposure to sediment suspensions for 3 or 6 weeks. These bioassays were conducted using eight 50-L capacity plexiglass aquaria. At the time of each bioassay, identical volumes (25 L at 3 weeks, 40 .L at 6 weeks) of a 150 ug·L-1 solution of pentachlorophenol dissolved in clear freshwater ( 15oc dechlorinated tap water; NFR < 5 mg·L-1) were prepared (Alderdice 1963; McLeay et al. 1983) and added to each aquarium. Ten fish, selected randomly from each test stream, were placed in each aquarium. The time to death of each fish was measured and recorded. Upon death, each fish was removed from the aquarium and its length and weight determined. The effect of exposure of grayling to sediment suspensions for 6 weeks on fish respiration was assessed by sealed jar bioassay. Test procedures ( McLeay 1976; Gordon and McLeay 1977) were those used for evaluating the respiratory responses of naive (previously unexposed) grayling to placer mining sediment (McLeay et al. 1983). Following the 6-week exposure perlod, b-L volumes of test suspensions (or control water) from each of the eight test streams were heated to 2ooc (test temperature) and aerated vigorously for 30 min to ensure oxygen saturation. Dissolved oxygen values were measured and each suspension [ [ [ [ [ [ [ r l [ [ [ r . L [ [ [ [ [ [ [ [ n L [ r: l r· L -11 - transferred to ten 140-ml clean glass jars. Ten test fish, selected from each stream for similar size ( I\./ 1. 3 g) were placed in these jars, one fish per jar. Each jar was then filled with the appropriate test suspension and sealed (plastic lid) to exclude air. Upon the death of each fish, t~me to death, water temperature, and fish length and weight were recorded. The residual dissolved oxygen level in each suspension was measured using a portable oxygen meter (Delta Scientific Model 1010) with mechanical agitator. The effect of prolonged (6-week) exposure of grayling to suspended sediment on their upper lethal temperature tolerance was evaluated by critical thermal maxima bioassays (McLeay and Howard 1977; McLeay and Gordon 1980). The apparatus and procedures used for these bioassays were identical to those employed previously with naive grayling and differing strengths of suspended inorganic sediment (McLeay et al. 1983) ·~ A 50-L volume of each test suspension or control water was collected (as 4 sub-samples of 13 L each) from each test stream and placed in each of eight rectangular plexiglass tanks. Each suspension (or control water) was recycled from the conical bottom of the tank at 10 L•_min-1 (McLeay et al. 1983). Each tank was lined with a soft-mesh nylon basket. All remaining grayling (8 17) in each test stream were transferred to the appropriate recycle tank. Water temperature in each tank was initially 15.:!:. 0.1oc. This temperature Wc;iS increased progressively at a controlled rate of 10C·h-1 (thermostatically- controlled immersion heaters) until all fish in each tank were dead. Baskets were raised at frequent intervals to permit observation of dying/dead fish. The temperature ( ± 0.10C) of each test suspension was recorded at the time of death of each fish. Upon death, each fish was removed for length and weight determinations. Statistical analyses The condition factor ( K) of test fish after 3 and 6 weeks' exposure to differing sediment strengths was determined as follows: K = cW·L-3 where c is a constant ( 100), W is wet weight (g) and L represents fork length in em (Carlander 1969). Mean and standard deviation (SD) values for fish length, weight, and condition factor were calculated for each fish group. Mean ± SD wet weights for all fish in each test stream, as determined weekly throughout the study, were also calculated. Additionally, mean ± SD values for all other variables determined for groups of grayling during the feeding trials and tests for assessment of fish condition and performance were determined. Mean + SD values for each water quality characteristic monitored daily for-each stream throughout the 6-week test period were also calculated. For certain values shown graphically, the 95% confidence interval ( CI) for each mean was determined. Mean weekly fish weights for each of the four sediment treatments were calculated together with their 95% confidence intervals after 6 weeks' sediment exposure. -12 - Lethal times to death of 50% (LT50 values) of each group of ten grayling exposed to the reference toxicant pentachlorophenol or examined for performance in sealed jar bioassays were calculated, together _with their 95% confidence intervals, by log-probit analyses (Litchfield 1949). Provided that the median reaction times for replicate treatments did not differ significantly (Litchfield 1949), LT50 values for each treatment ( n=20) were determined and examined for significance of difference from corresponding values for control fish, according to Litchfield (1949). Fish weights determined weekly for each test stream were compared at each time interval using a 1-way analysis of variance (ANOVA). Values derived for identical treatments were pooled. For all comparisons where a significant difference in ANOVA was found (P <0.05), Dunnett's test (Zar 1974) was employed to test for significance of each treatment versus the control group. Values derived for residual oxygen levels at death (sealed jar bioassays) and upper lethal temperatures at death (temperature tolerance tests) following a 6-week exposure of grayling to differing sediment strengths were also compared in this manner. RESULTS SEDIMENT CHARACTERISTICS AND DISPERSAL Particle size distributions for the samples of untreated or prepared (pulverized) settling pond sediment analysed for this study are presented in Table 1. Analysis of the untreated test sediment (as sampled from the settling pond) indicated that the majority (62%) of material present was fine to very fine sand ( > 45 urn), and only 23% of the sample was comprised of silt-or clay-sized sediment fines ( < 38 um). Unlike this sample, each of the samples of prepared (test) sediment analysed was comprised of 70. -71% silt or clay rna terial ( < 38 urn) (Table 1). Particle sizes for all but 2 -3% of each of these samples were < 75 um. Volatile/fixed residue content and oxygen uptake rate (in freshwater at 150C) for replicate samples of the test sediment are given in Table 2. The values derived for oxygen uptake rate are identical to those found previously for inorganic placer mining sediment (McLeay et ai. 1983), and are indicative of an inert sediment with little, if any, oxygen demand. The residue analyses (Table 2) support this observation, inasmuch as only 4 -5% of the test sediment was comprised of volatile (organic) material. Results from the plasma scan analysis of two samples of the test sediment for metal content are given in Table 3. As with the other sediment characteristics examined, the concentrations of specific metal constituents in each sample were very similar (i.e. the characteristics analysed for different portions of the test sediment [ [ [ [ [ [ I, L [ [ [ [ [ [ [ f' [ r L [ [ f' L I , L -13 - were homogeneous). These values are presented for purposes of sample "fingerprinting" only. Strengths of specific metals dissolved in freshwater suspensions of the test sediment (and conceivably biologically available) were not analysed in this study. The relationship of sediment strengths in the barrel reservoirs to those mantained in suspension within the test streams is illustrated in Figure 2. This relationship was linear with respect to concentration; i.e. for all concentrations examined the sediment strengths made up in the barrel reservoirs were approximately five times the nonfiltrable residue values measured in the test streams. Results in Figure 2 and those in Table 4 indicate that stream position (horizontal distribution) did not affect the suspended sediment strength. Non-filtrable residue values for water samples taken concurrently from upstream, mid-or downstream positions did not differ appreciably for any of the test strengths examined. The vertical or cross-stream distribution of suspended sediment strengths within the test streams were not examined. WATER QUALITY Mean .:!:. SD values for the freshwater supply, as determined from grab samples taken weekly ;following the receipt of test fish, were as follows: temperature 15 ~ 0.5oc, pH 6.6 ~ 0.1, dissolved oxygen 9.3 ~ 0.2 mg·L-1, conductance 26 ~ 4 umho•cm-1, alkalinity 1.8 ~ 0.6 mg·L-1, EDTA hardness 4.1 ~ 0.2 mg·L-1, and nonfiltrable residue < 5 mg·L-1. Water quality characteristics determined daily for each test stream throughout the 7-day acclimation period and the subsequent 6- week exposure period are given in Appendix 1 and summarized in Table 5. Daily fluctuations in stream NFR and turbidity values are illustrated in Figures 3 and 4, respectively. The rate of inflow of fresh suspensions of sediment or control water to each test stream was nearly constant throughout the exposure period (Appendix 1), and did not differ appreciably between streams (Table 5). Mean water temperatures for streams 1 - 7 were similar and did not vary greatly during the study. However, the temperature for stream 8 (control stream) water was consistently less than that for all other streams (mean value 0.9 -1.6oc lower; Table 5). Dissolved oxygen values for all. stream samples were ~0% air saturation (~ 8.8 mg 02·L-1), and were unaffected by sediment treatment. Mean pH values for each stream were similar (6.5 -6.7). The conductivity (ionic strength) of streamwater was increased slightly but consistently due to the higher sediment strengths (300 and 1000 mg·L-1), with mean daily values of 30 or 36 UIJh'J.o~ cm-1 respectively (control water 25 umho·cm -1) (Table 5). -14 - Nonfiltrable residue values for the control water (streams 4 and 8) were consistently below the limit of detection ( < 5 mg·L-1). Mean NFR values for streams 2 and 5 (nominal strength, 100 mg·L-1) were 86 and 93 mg·L-1 respectively, with mean values of 286 or 273 mg·L-1 (streams 3 and 6) and 988 or 955 mg·L-1 (streams 1 and 7) for nominal suspended sediment strengths of 300 or 1000 mg·L-1. The NFR values measured daily for each of these test streams varied somewhat, with slightlY, higher values for each respective stream evident during the third and fourth weeks of exposure (Fig. 3, Appendix 1). However, no overlaps of any NFR values occurred between the differing sediment treatments employed (100, 300 or 1000 mg·L-1). As with stream NFR, daily and mean turbidity values for identical treatments were similar (Fig. 4, Table 5). Turbidity values for all samples of clear (control) freshwater analysed were < 3 FTU. The pattern of daily fluctuations in turbidity values for grayling exposed to 100, 300 or 1000 mg·L-1 suspended sediment was similar to that noted previously for NFR values (see Fig. 3 and 4). FISH SURVIVAL AND GROWTH All . of the sixty fish. placed in each of the eight test streams survived the initial 7 -day acclimation period following their transfer. Thereafter, dead fish were found occasionally in each stream during the subsequent 6-week test period. These deaths occurred randomly and were unrelated to sediment treatment (Table 6). The majority (68%) of dead. fish were found during the initial 2-week test period. Overall, 8% of the test fish died or were unaccounted for (presumed to be dead) during the 6-week test period (Table 6). Examination of the dead fish indicated that 77% (20 of 26) had lacerations to the abdominal region or to the dorsal body region immediately posterior to the opercula. The six remaining dead fish appeared normal or were sufficiently decomposed to prevent the detection of these injuries. The gross examination of gill tissue for each dead fish showed no signs of clubbing, accumulation of sediment particles, or excessiv.e mucous production. All moribund fish observed in clear water (controls) showed evidence of physical injury (nips or tears), and aggressive fish interactions resulting in deaths of otherwise healthy fish were noted on two occasions. Similarly, a high percentage of fish deaths found for the stock population of grayling reared in the outdoor trough were caused by excessive fish aggression. The initial mean weights (and standard deviations) for each group of sixty grayling transferred to the test streams were nearly identical (Table 7). Weight gains during the initial 7-day period of acclimation to each stream (clear freshwater only) were also similar and were substantial (increases of approximately 25%). Differences in fish weights due to treatment were not apparent after 1 or 2 weeks' [ [ [ [ [ [ I, L [' [ [ [ L [ - B [ [ I : L r L -15 - exposure to any sediment strength. However, for each of the subsequent exposure periods examined, the mean weights of each group of control fish were greater than those for any sediment treatment (Table 7). Reduced growth due to sediment exposure was concentration- dependent. The average percentage weight= gain experienced for each treatment during the test period was as follows (based on differences in mean weights of fish at 0 vs. 6 weeks' exposure; Table 7): 0 100 300 1000 mg·L-1 mg·L-1 mg·L-1 mg·L-1 241 % increase 227 % increase 217 % increase 161 % increase Relative to the control values, there was a 33, 10, and 6% reduction in growth of fish exposed to 1000, 300 and 100 mg• L-1 suspended sediment, respectively. The analysis of variance of weekly fish weights showed that the differences in variances due to sediment treatment were significant (P < 0.05) at 2 weeks; and highly significant (P <0.01) after 3, 4, 5, and 6 weeks' sediment exposure. Dunnett's test for significance (Zar 1974) indicated that weights for fish exposed to the highest sediment strength examined (1000 mg·L-1) were decreased significantly from respective values for control fish at 2, 3, 4, 5, and 6 weeks. Corresponding weights for fish exposed to 100 and 300 mg·L-1 sediment were depressed significantly from control values after 3, 4, and 5 weeks' sediment exposure. Differences between values-for these lower sediment strengths and controls did not differ statistically ·following 6 weeks' exposure. FISH BEHAVIOUR Distribution in streams Routine daily observations of fish surfacing to feed in each test stream indicated that those held in the higher sediment strengths (300 and 1000 mg·L-1) were usually distributed in the downstream half. Unlike these observations, grayling held in clear freshwater or in 100 mg·L-1 sediment were distributed along the length of the stream, feeding actively in the upstream half as well as the downstream portion. This pattern of fish distribution was evident within 1 hour of the initial introduction of sea1ment to test streams and, thereafter, throughout the 6-week expo~ure period. With the exception -16 - of these periods of feeding; surfacing of fish in the test streams was not observed. Other observations of fish behavioural responses (i.e. coughing, threats, nips, swimming activity) could not be made due to the opacity of all test suspensions examined. The percentage distribution of grayling in each quarter of each test stream, after 4 and 5 weeks' exposure to placer mining sediment, is shown in Table 8. Fish distributions during these periods of observation were unaffected by feeding activity since no food was offered on each day prior to the determinations of fish distribution (and weight). For the control streams and those containing 100 mg·L-1 sediment, the distribution of fish in each stream quarter appeared to be somewhat random and unaffected by sediment treatment. The average distribution of fish in the upstream and downstream halves of these test streams was approximately equal although the majority of fish (62%) were found within the second and third quarters. Unlike this finding, the average percentage distribution of fish in the downstream half (third and ·four quarters) of each stream containing 300 or 1000 mg·L-1 suspended sediment was 80 -91% (Table 8). These data, together with the subjective observations of fish distribution during routine feeding, indicate that the majority of test fish were displaced downstream by the higher strengths of suspended sediment (300 and 100 mg·L-1). Feeding response trials For each of the three feeding response trials conducted with grayling using live surface drift (Drosophila melanogaster), the rate of response to fruit flies for fish in each clearwater (control) stream was similar (mean values, 6 - 8 sec) (Table 9). Mean response times were increased consistently by all sediment strengths examined including 100 mg·L-1. Response times increased progressively with increasing suspended sediment strength (Table 9, Fig. 6). In all but three of the 45 separate tests conducted with the highest sediment strength (streams 1 and 7), the fruit fly was consumed within the 360- second test period (Table 9). Mis-strikes (failed feeding attempts) were noted frequently for fish reared and tested in 300 and 1000 mg·L-1 sediment but were not observed for those held in clear water or 100 mg·L-1 sediment. The increased response times to surface drift measured in these controlled feeding trials were consistent with observations made during the routine (daily) feedings with commercial ration (Biodiet). At these times, control fish in each stream surfaced and initiated feeding activity more rapidly than those held in 100 mg·L-1 or higher suspensions. Lag times pr•ior to initiation of feeding were consistently longest for fish held in 1000 mg·L-1 sediment. Differences in response times for fish reared in 100 vs. 300 mg·L-1 could not be discerned. [ r· l [ [ r: L l - [ L L [ . L I : L [ L L [ f' L [ [ I , L I- L -17 - The feeding response times to surface drift for naive grayling (those held in test streams for 1 h prior to testing) are given in Table 9 and illustrated in Figure 6. In these trials, the response of control fish was somewhat more variable than that noted previously for acclimated fish (Table 9), with mean values of 10 -25 seconds. Mean response times were agaiq increased due to increasing strength of suspended sediment (Fig. 6). For each respective sediment exposure, mean response times were similar but appreciably longer than those recorded previously for grayling reared in test s~earqs for 5 weeks prior to evaluation. Failure to feed was noted for 18 of the 24 tests with naive fish held in 1000 mg•L -1 sediment, and for 3 or 6 (respectively) of the 24 tests with naive fish held in 100 or 300 mg•L -1 sediment (Table 10). Feeding mis-strikes were noted for fish held in the higher sediment strengths, but were less frequent than those observed in the previous feeding trials. The feeding response of grayling to sub-surface drift (live brine shrimp) following 6 weeks' exposure to differing strengths of suspended sediment is given in Table 11 and summarized in Figure 7. For each of the three trials conducted, the response times for identical treatments were similar. No consistent differences in response to sub-surface drift were found for groups of fish reared and tested in 0, 100, or 300 mg·L-1 sediment (Table 11, Fig. 7) Mean times for consumption of all brine shrimp offered were 3 - 8 min. Unlike these findings, times to consumption of brine shrimp were increased due to 1000 mg·L-1 sediment. Test fish held in this sediment strength consistently failed to consume all of the brine shrimp offered within the 60-min test period (Table 11). Suspended sediment strengths of 100 and 300 mg·L-1 did not affect the feeding response times for grayling held in test streams for 5 weeks or 1 hour and fed live tubificid worms (Table 12). Irrespective of the length of previous exposure, mean response times for consumption of all worms by control fish or those held in 100 or 300 mg·L-1 sediment were 3 -10 min, and no consistent changes in response due to treatment were observed (Fig. 8). However, the highest sediment strength examined (1000 mg·L-1) inhibited the feeding response of naive or previously exposed fish to these benthic invertebrates, with 0 -10% worms consumed in any test during the 60- min period. CORDITIOH OF FISH General Inspection of grayling sampled from each test stream after 3 or 6 weeks in differing strengths of placer mining sediment .revealed no overt signs of disease or damage attributable to these sediment exposures. A small but consistent incidence ( <5%) of fish with spinal deformities (crinklebacks) became evident in each stream -18 - (including control streams) during the test period. However, no body lesions were evident. Fins and opercula of all fish appeared normal, and no internal or external hemorrhages were observed. Gross examination of the gills of each fish showed no signs of clubbing, discolouration, excess mucous production, or adhesion of sediment particles. All fish sampled from the highest strength of sediment tested ( 1000 mg·L-1) were notably paler than control fish, and parr marks were indistinct. Those held in 300 mg·L-1 sediment were only slightly paler than fish reared in clear freshwater. No differences in appearance were discerned for fish reared in 100 mg·L-1 sediment vs. control water. Fish length and condition factor Mean condition factors (100 W·L-3) for all fish sampled from each stream after 3 or 6 weeks' sediment exposure differed randomly and were not affected by treatment (Table 13). Mean values varied from 0.81 to 0.96; standard deviations for each sample were similar (Table 13). Mean lengths (and weights) determined for the group of ten fish sampled from each stream after 3 weeks' exposure to placer mining sediment were not considered to be representative of overall stream values due to the smail sample size. Mean fork lengths for all groups of sediment-exposed fish sampled at 6 weeks (n = 42-47) were consistently smaller than this value for either group of control fish, with greatest differences noted between lengths for controls and those exposed to 1000 mg·L-1 sediment (Table 13). Biological characteristics The biological characteristics determined for each group of ten grayling sampled from each stream after 6 weeks' sediment exposure are given 1n Table 14. The mean percentage body moisture content for fish from each stream was similar (77 -79%) and apparently unaffected by sediment treatment. Hematocrit and leucocrit values for fish were also unchanged by prolonged exposure to any sediment strength (Table 14). Mean plasma glucose values for each sample were consistently low (58 -68 mg%) with no consistent changes in magnitude or sample variance caused by any of these sediment strengths. r [ [ [' r- L ! : L r: L [ [ [ c L I , L L -19 - PERFORMANCE OF FISH Tolerance to reference toxicant Data concerning the acute lethal tolerance of test fish to penta- chlorophenol, following a 3-week exposure to differing strengths of suspended sediment, are given in Table 15 and illustrated in Figure 9. Based on these median time-to-death (LT50) values, grayling reared for 3 weeks in the lowest strength of sediment examined ( 100 mg·L-1) were more tolerant to this reference toxicant than the control fish or those held in the higher sediment strengths (300 and 1000 mg·L-1). Response times for identical treatments did not differ significantly for any comparison. However, times to death for all fish reared in 100 mg·L-1 sediment were significantly (P < 0.05) longer than those for control fish or grayling reared in 1000 mg·L-1 sediment. After 6 weeks' exposure to sediment, the tolerance to pentachlorophenol for both control groups and fish reared in 100 mg·L-1 sediment was similarly high (Table 16, Fig. 10). Unlike these values, times to death in pentachlorophenol for fish reared in 300 or 1000 mg·L-1 sediment were consistently and appreciably shorter. Statistical analyses (Litchfield 1949) indicated that response times for streams receiving identical treatments did not differ (P >O .05), whereas values for fish held in 300 or 1000 mg·L-1 were significantly lower than those for controls. These results indicate that the acute lethal tolerance of grayling to this reference toxicant was depressed by prolonged exposure to these higher strengths of suspended sediment. Respiration Findings from the sealed jar bioassays indicate that the short- term capacity of grayling to withstand hypoxic conditions was unaffected by their prolonged exposure to sediment. Mean residual dissolved oxygen values derived for fish from streams rece1v1ng identical treatments were somewhat variable and showed no consistent change with respect to sediment strength (Table 17, Fig. 11). Addi- tionally, the 95% confidence intervals for differing treatments showed considerable overlap (Fig. 11). Unlike these findings, times to death of fish exposed to 300 or 1000 mg·L-1 sediment in these sealed jar bioassays (and for 6 weeks in test streams) were decreased consistently relative to corresponding values for control fish or those held in 100 mg·L-1 sediment (Table 17, Fig. 12). These declines proved significant (Table 17), whereas values derived for fish from separate streams receiving identical treatment did not differ (P >0.05) for any comparison. Based on mean fish weights; times to death, and residual dissolved oxygen values at death of fish in sealed jars after 6 weeks' sediment exposure, oxygen uptake rates (mg 02•g fish-1-h-1) were calculated for each group of ten fish from each test stream. Results obtained were as follows: -20 - Sediment Stream Oxygen uptake rate strength no. (mg o2·g fish-1·h-1) ( mg·L-1) 0 4 2.1 0 8 2.2 100 2 2.1 100 5 2.2 300 3 2.3 300 6 2.3 1000 1 2.5 1000 7 2.5 These results show an increase in oxygen consumption rates for each group of fish exposed to the two higher strengths of suspended sediment only. Temperature tolerance Upper lethal temperatures (mean .:!: SD) for test grayling held in differing suspended sediment strengths following their 6-week exposure are given in Table 18. Mean temperatures at death for fish from each stream, together with their 95% confidence intervals, are depicted in Figure 13. The mean temperature at death for fish from one control stream (stream 4) was similar to values for ail groups of fish exposed to placer mining sediment (27. 7 -28 .ooc). The 95% confidence intervals for these groups were similarly small (Fig. 13). However, the mean temperature at death for the second control group (stream 8) was notably lower (27.00C) and its 95% confidence interval expanded. Analysis of variance indicated that differences in lethal temperatures between treatments were significant (P <O .01). Additionally, pooled values for each sediment treatment differed significantly from those from the pooled control value according to Dunnett's test (Zar 1974). Mean temperatures of acclimation for fish from each stream during the 6-week period of sediment exposure are also presented in Table 18. The acclimation temperature for stream-4 fish ( 15.20C) was consistent with those for fish held for 6 weeks in differing sediment strengths (14.9-15.6°C), whereas controls reared in stream 8 were acclimated to somewhat cooler (14.00C) water. l t r l I l r [ [ [ [ [ [ r L [ L r~ L -21 - DISCUSSION SEDIMENT DISPERSAL/COHCENTRATIOH IH TEST STREAMS Based on daily observations during cleaning/refilling of the sediment suspensions in each barrel reservoir, little if any settlement of sediment occurred w1J~hin these barrels. Thus the 5-fold difference between sediment strengths in barrels and nonfiltrable residue values in test streams (Fig. 2) was due primarily to the set- tlement of larger-sized sediment particles on the stream bottom. This conclusion is consistent with the observation of a concentration - dependent buildup of packed sediment < 2 em in depth on the bottom of each stream during the. weekly cleaning periods. k portion of the sediment suspended in test strengths may also have passed through the 0. 45 urn filter upon analysis (and therefore not have contributed to the NFR values derived). However, based on previous analyses of sus- pensions of similar inorganic sediment for both nonfiltrable and total residue content (McLeay et al. 1983), the contribution of test sediment to this filtrable portion of stream water would likely have been minimal. Although the vertical or cross-stream gradients of suspended sediment within each test stream were not examined, it is thought that the relatively shallow depth and narrow width of each stream, together with the rapid rate of mixing and recycling of each test suspension, would have negated any marked stream gradients. The visual inspection of surface and sub-surface grab samples of water from a number of positions within each test stream supported this conclusion. Additionally, stream-length gradients of differing suspended sediment strength were not apparent (Table 4, Fig. 2). The daily variations in nonfiltrable residue and turbidity values determined for each test stream (Figs. 3 and 4) are due to a number of variables including minor mod.ifications to the amount of sediment added to the barrel reservoirs at 2 and 4 weeks, unknown experimental error, and errors in precision of the analytical techniques (Anon. 1979, 1980). Despite these inherent/experimental errors, suspended sediment strength and turbidity for each test stream were reasonably constant throughout the 6-week exposure period, and mean nonfiltrable residue values for streams . to which test fish were exposed approximated (albeit values were 1 15% lower) the desired concentrations of 100, 300 or 1000 mg·L-1 (Table 5). Relative to daily. (or hourly) changes in turbidity or suspended sediment strength for streams receiving discharges from placer mining activities (McLeay et al. 1983), the variations for these variables recorded in th~ present study are minor. Additionally, the control/diluent water remained clear (NFR < 5 mg·L-1, turbidity< 3 FTU) throughout the study period. -22 - FISH SURVIVAL AND GROWTH With th~ exception of the suspended sediment loadings, water quality within all test streams was compatible with fish survival and near optimum for growth of grayling. Freshwaters with dissolved oxygen values > 90% saturation are not restrictive in terms of the condition and performance of cold-water fish species (Davis 1975), and stream pH values of 6.5 -6. 7 are considered within the range of normal values. Although the optimum temperature for growth of Arctic grayling has not been defined, the test temperature of 15oc approaches the physiological optimum determined for other juvenile salmonid fish species (Brett et al. 1969; Brett 1971). The minor increase in stream conductivity due to the highest sediment strength examined would not cause any osmotic stress to test fish; however, the impact of specific (unmeasured) ions leached from the sediment on fish growth and well- being cannot be ascertained from the present study. Water currents in test streams did not cause undue energy·demands. The present findings indicate that prolonged (6-week) exposure of underyearling Arctic grayling to strengths of suspended placer mm.ng sediment <1000 mg·L-1, under otherwise optimal water quality condi- tions inclUding the readily available excess food, does not affect fish survival. These findings are consistent with our previous (McLeay et al. 1983) observations for grayling held in suspended sediment strengths 50000 mg·L-1 for 2 weeks or less, and with earlier (Griffin 1938, Herbert and Richards 1963) reports of survival of rainbow trout (Salmo gairdneri) or Pacific salmon fingerlings exposed to suspended sediment strengths ranging from 200 to 750 mg·L-1 for several weeks or months. On the other hand, suspensions of natural sediments in the range of 1000 -2500 mg·V-1 have been reported to cause deaths of young salmonid fish within 3 weeks or less (Campbell 1954; Noggle 1978). The European Inland Fisheries Advisory Commission (Anon. 1965) reviewed these and other findings of fish death or survival in sediment suspensions, and attributed the diverse results to differences in sediment particle size, angularity or hard- ness. The significant reduction in the growth of grayling exposed to 100, 300 or 1000 mg·L-1 suspended placer mining sediment for periods of 3 to 6 weeks are consistent with previous findings for growth studies with sediment-exposed salmonid fish. Herbert and Richards (1963) reported growth impairment for rainbow trout reared for 33 -40 weeks in suspensions of coal-washery waste or wood fibre as low as 50 mg·L-1. Similarly, Sigler ( 1981) found reduced growth for underyearling steelhead trout (~ gairdneri) or coho salmon (Oncorhynchus kisutch) held for 2 weeks in laboratory streams containing suspended clay solids with turbidity values of 40 -60 NTU. Depending on the nature and availability of the food supply, settled sediment fines may also con.strict the growth of stream-reared fish (Crouse et al. 1981). l l I L [ [ L [ r L [ lJ [ L I' L -23 - Unlike the findings for grayling in test streams rece1v1ng 1000 mg·L-1 suspended sediment, those reared in 100 or 300 mg·L-1 sediment grew nearly as well as the control fish. However, these fish were presented with an abundant supply of food throughout the test period. Based on the findings from the feeding response trials with live food organisms, it is thought that these lower suspended sediment strengths, if present within natural streams for extended periods of time, could result in a greater impairment of fish growth than was observed here. FISH DISTRIBUTION Since the predominantly downstream distribution of grayling exposed to the higher suspended sediment strengths (300 and 1000 mg·L-1) was observed within one hour of the initial establishment of the sediment gradients, it is unlikely that this behavioural response was caused by movement downstream in search of food. Rather, these findings suggest an innate downstream movement of these fish in response to sediment exposure. Sigler ( 1981) found downstream displacement of steelhead trout and coho salmon fry from artificial streams receiving clay suspensions with turbidity values of 40 50 NTU. Noggle (1978) reported avoidance responses for juvenile coho salmon exposed to suspended sediment strengths of 4000 -8000 mg·L-1, whereas lower strengths (1000 -4000 mg·L-1) caused preference responses (fish attraction). Other investigators have reported no response ( Gradall and Swenson 1982), preference (cited in Noggle 1978) or avoidance reactions (Anon. 1965) for other species of salmonid fish exposed to · low-to-medium ( <1000 mg·L-1) strengths of suspended sediment under controlled conditions. Berg (1982) determined that short-term pulses of suspended sediment with turbidity values ..$_60 NTU caused a breakdown of social organization for juvenile coho salmon in laboratory stream environments, resulting in increased activity and a loss of aggressive interactions. From the foregoing, it is apparent that the behavioural responses of stream fish to suspended sediment are, as yet, unclear; and that differences in fish species, age, and sediment strength and type (particle size and shape) may result in diverse behavioural reactions. Fish distribution in natural stream environment:;3 c~n be II~firkedly affected by suspended sediment loadings. Several instances of salmonid or other fish species avoiding muddy streamwater have been reported (Anon. 1965). Herbert et al. (1961) reported an absence of brown trout · (Salmo trutta) fry from downstream sites for streams receiving china-clay wastes; whereas these fish were abundant at up- stream, clearwater sites. Similarly, Birtwell et al. (1984) recently found a consistent reduction in numbers of juvenile Arctic grayling within downstream water receiving suspensions of placer mining sediment, relative to numbers found in upstream creekwater or clear- water tributary streams. These findings provide evidence for a displacement of juvenile Arctic grayling or other salmonid fish species from stream environments caused by high suspended sediment loadings. : 24 - FEEDING BEHAVIOUR OF FISH As with other salmonid fish species, the feeding habits of Arctic grayling yary depending on life stage. Underyearling grayling feed primarily on zooplankton or drift from benthic invertebrate larvae, whereas larger juveniles ( > 13 em) or adult grayling tend to feed on benthic or emergent insects and larger terrestrial insect drift (O'Brien et al. 1979; Schmidt and O'Brien 1982; Birtwell et al. 1984). An examination of stomach contents for underyearling grayling captured during summer months from clearwater Yukon streams indicated that these fish were feeding principally on aquatic invertebrate drift (Chironomidae, Simuliidae) (Birtwell et al. 1984) • . Schmidt and O'Brien ( 1982) determined that the reactive distance of Arctic grayling (i.e. distance within which a positive feeding response occurred) to a number of live zooplankton species was increased with increasing light intensity. Although several salmonid fish species appear to reach their maximum visual acuity at ·a light intensity of about 100 lux (Schmidt and O'Brien 1982), these investi- gators found that reactive distances for grayling increased up to a iight intensity of 20000 lux. Based on these findings, these authors concluded "Because grayling, at least in the Arctic, may do much of their feeding under conditions of continuous daylight and very clear water, (genetic) selection for ·low light vision may be low." Our findings from feeding response trials with Arctic grayling and live food organisms support this previous evidence that grayling rely on visual cues to locate insects, and that decreased light intensity (due in this instance to suspended solids) will impair feeding responses for this fish species. Present results indicate clearly that a 1000 mg·L-1 suspension of placer mining sediment markedly impairs the feeding performance of underyearling grayling offered surface drift, sub-surface drift or benthic invertebrates. This impaired response is evident for both naive fish and those exposed continuously to this suspended sediment stength for 5 or 6 weeks. Interpretation of the effects noted for fish held in the lower sediment strengths (100 or 300 mg·L-1) are less clear and confounded by modifications in the experimental approach used with differing food organisms. The increase in time to respond to surface drift for fish chronically exposed to 100 or 300 mg·L-1 sediment suggests that these sediment strengths (and 1000 mg·L-1) decreased the fishes' reactive distance (ability to detect surface prey). The relatively slower reponse to surface drift for naive grayling held only briefly in these sediment strengths prior to testing may indicate that those fish subjected to prolonged sediment exposure have improved their ability to discern surface food in turbid water. Alternatively, short-term exposure to these sediment strengths may have disrupted feeding activities to some extent. The similarly rapid feeding response times for naive controls versus long-term controls shows that the feeding activity of naive fish was not disrupted by transfer of fish from the stock tank to the test apparatus. l l l I l I L [ L r, L [ [ [ r : L -25 - Unlike the findings with surface drift, suspended sediment strengths of 100 or 300 mg·L-1 did not impair feeding response times for grayling offered sub-surface drift (Artemia salina) or benthic invertebrates ( tubificids). The ability of naive or chronically- exposed grayling to detect and consume tubifex worms or brine shrimp ih these sediment strengths equally as well as control fish was likely due at least in part to the experimental design for this test. The white background provided by the submersed nylon-mesh baskets may have silhouetted these prey, making their· detection easier. Additionally, holding fish within the confines or·-"each basket may have decreased the distance between predator and prey sufficiently for these fish to readily detect (and consume) these organisms at these sedime~t strengths. Or perhaps the reactive distance for these sub-surface food organisms at each respective suspended sediment strength, whether related to visual or olfactory cues, is greater than that for surface drift. Several investigators have reported a reduction in the feeding responses of salmonid fish due to the presence of suspended sediment. Noggle (1978) found that a suspended sediment strength of 100 mg·L-1 reduced feeding of coho salmon smolts toward caddis fly larvae by 45%, . and that feeding ceased altogether above 300 mg·L-1. Although both juvenile cutthroat trout (Salmo clarki) and chinook salmon (Oncorhynchus tshawytscha) can continue to feed on surface drift in suspended sediment concentrations greater than 500 mg·L-1 (Griffin 1938), one study (Anon. 1965) reported that cutthroat trout subjected for two hours to 35 mg·L -1 suspended sediment within a river sought cover and stopped feeding. Berg ( 1982) determined that suspended sediment with a turbidity of 60 NTU had a marked effect on the visual ability of juvenile coho salmon. Delayed response times to surface drift, mis-strikes at food, and frequent collisions of fish with an obstacle within the test tank were evident. These findings are con- sistent with those for Arctic grayling (particularly naive fish) offered surface food in the presence of sediment suspensions >1 00 mg·L-1. FISH CONDITION With the exception of fish colour, all grayling reared for 6 weeks in placer mining sediment suspensions < 1000 mg·L-1 were normal in appearance, showing no overt pathologies attributable to sediment exposure. The observation that fish exposed to 300 and 1000 mg·L-1 were paler in colour is consistent with other findings for salmonid fish exposed to elevated suspended sediment levels under field . or laboratory conditions (Herbert and Merkens 1961, Herbert et al. 1961), and probably reflects a contraction of epithelial chromatophores in response to background colour. Mean condition factors determined for groups of fish held for 3 or 6 weeks in control streams or those containing differing strengths of suspended placer mining sediment were typical of those values found .l.LA~KA RESOURCES LYHRAO ti.J. DEPT. OF IXTEr:;oR -26 - for underyearling Arctic grayling captured from clearwater Yukon streams (Birtwell et al. 1984). As in the present study, Sigler (1981) found no change in condition factors for underyearling steelhead trout or coho salmon held for extended periods in laboratory streams containing sediment suspensions, whereas these fish grew less than the control fish in clear water. Fish were provided an excess food ration in both studies. Webb and Brett ( 1972, 1973) reported a similar growth impairment (without change in condition factors) for underyearling sockeye salmon (Oncorhynchus nerka) exposed to sublethal concentrations of kraft pulpmill effluent or pentachlorophenol, together with a reduced food conversion efficiency. As .in the current investigation, the percentage moisture content of these contaminant- exposed salmon was unchanged. A reduction in food conversion efficiency could be caused by increasing maintenance energy costs, thus reducing the proportion of energy available for growth (Warren and Davis 1967);. ie. reducing the "scope for growth" (Brett 1976). The reduced growth of grayling or other salmonid fish species caused by suspended sediment may also reflect a decreased food intake, al- though it is thought that this would be reflected in a reduction in fish condition factor. As with other increased metabolic demands, a sustained increase in swimming activity of fish due to suspended sediment (Berg 1982). would increase energy costs, resulting in less energy available for growth. Since blood hematocrit values for salmonid fish generally increase due to hypoxia (caused by impaired ga·s exchange or oxygen- deficient waters) (Holeton and Randall 1967; Soivio et al. 1974 a,b), the absence of any change in hematocrit for grayling exposed to sus- pended sediment for 6 weeks suggests that these exposures did not lower blood oxygen tension. O'Connor et al. (1977) reported elevated hematocrits, red blood cell counts and hemoglobin values together with ·histological evidence of gill damage for certain species of estuarine fish exposed to suspended sediment, whereas for other species these blood values and gill histology were unchanged from controls. Hematocrit values and gill histology of underyearling Arctic grayling were shown previously to be unaffected by acute ( ~ 4 days) exposure to suspensions of placer mining sediment under field or laboratory conditions (McLeay et al. 1983). A lack of change in hematocrit values does not necessarily imply no gill tissue damage, however, since fish have a large "reserve" surface area of gill tissue available for maintaining blood gas tensions at normal values (Randall 1970). Exposure of Arctic grayling and other fish species to suspended sediment at strengths which can be found within natural streams has been shown to cause a number of typical stress responses, including short-term increases in plasma cortisol levels (Redding and Schreck 1980), depletion of liver glycogen energy reserves (Sherk et al. 1974, O'Connor et al. 1977), elevation of plasma glucose levels (Noggle 1978, McLeay et al. 1983) and depression of leucocrit values (McLeay et al. 1983). When the stress is prolonged, certain fish stress r l [ [ l I L [ [ [ [ r [ r L r L [ [ b r= L [' I= Li -27 - indices including plasma cortisol and glucose levels and numbers of circulating white blood cells ( leucocrit) recover to basal or near- basal levels ( McLeay and Brown 197 4, McLeay 1977, McLeay and Gordon 1977, Redding and Schreck 1980). These recoveries typify the stage of resistance to stress (Selye 1950), and are only achieved at a metabolic cost. Thus the apparent absence of change in leucocrit or plasma glucose values for Arctic grayling following 6 weeks' exposure to suspensions of placer mining sediment is not unexpected, and does not imply that these fish were not stressed. A better understanding as to whether or not the grayling · in this study were chronically stre.ssed by suspended sediment, and the stage of this response after 6 weeks' exposure ( ie. resistance or exhaustion stages; Selye 1950), would require a more detailed biochemical/histopathological examination of test fish. This was beyond the scope of th~ present investigation. FISH PERFORMANCE An examination of the performance of fish during or subsequent to their exposure to environmental stressors can provide meaningful in- formation concerning their condition and adaptive capabilities (Wedemeyer and McLeay 1981; Wedemeyer et al. 1983). The present sealed jar· bioassays, temperature tolerance tests and challenge tests with the reference toxicant pentachlorophenol enabled a better under- standing of the sublethal effects caused by prolonged exposure of Arctic grayling to suspensions of placer mining sediment. Results from the bioassays with pentachlorophenol showed that grayling exposed for 6 weeks to 300 or 1000 mg·L-1 suspended sediment were less able to withstand this reference toxicant than control fish or those held in 100 mg·L-1 sediment. Similarly, both groups of fish exposed to these higher sediment strengths for 6 weeks showed shorter times to death (increased oxygen uptake rates) in sealed jar bioassays. These results suggest that the adaptive capabilities of grayling were diminished by prolonged exposure to suspensions of placer mining sediment ~300 mg·L-1. The increased oxygen uptake rate found for grayling held for 6 weeks in 100 or 300 mg·L-1 suspended sediment may reflect an increased basal metabolic rate or a sustained increase in physical activity for these fish. This response indicates a decreased scope for activity of the fish (Fry 1971). Measurements of scope for activity have been used previously to assess the impact of environmental stressors on fish (Brett 1958; Wedemeyer and McLeay 1981). Since the ability of grayling to withstand hypoxia was unaffected by chronic exposure to any sediment strength examined (residual dissolved oxygen values were unchanged), the decreased times to death found in sealed jar tests for fish exposed to 300 or 1000 mg·L-1 sediment probably reflect heightened ~nergy demands for these fish rather than impaired blood gas exhange (D.J. Randall, pers. commun.). This conclusion is also consistent with the lack of change in hematocrit values for the sediment-exposed fish. -28 - Findings for the current temperature tolerance tests indicate that the capacity of all fish groups to withstand high· temperatures was unaffected by prolonged exposure to any strength of suspended sediment examined. This result is consistent with previous evidence that little if any change in the upper lethal temperature tolerance of salmonid fish is caused by aquatic contaminants which do not block oxygen exchange at the gills or otherwise impair tissue respiration (McLeay and Gordon 1980; McLeay et al. 1983). The reduced temperature tolerance found for one group of control fish (stream 8) simply reflects the slightly lower temperature to which this group of fish was acclimated (Brett 1952; Black 1953; McLeay et al. 1983). GENERAL Inasmuch as the sublethal effects of prolonged exposure of salmonid fish to suspended sediment have previously received little attention, the harmful effects caused by such exposures are not clearly understood. The present study indicates that, at least for the sediment type examined, direct fish mortalities are unlikely from exposure to suspended sediment strengths less than or equal to 1000 mg·L-1 under otherwise optimal environmental conditions. However, sublethal effects including a continued impairment of feeding activity, impaired growth, decreased scope for activity and decreased resistance to other environmental stressors can occur. Present findings indicate that strengths of suspended placer mining sediment as low as 100 mg·L-1 can affect fish growth and feeding responses, and that strengths of 300 mg·L-1 or higher can increase oxygen consumption (metabolic rate), lower the tolerance of grayling to a reference toxicant, and cause fish to be distributed further downstream. These findings provide cause for concern if sediment concentrations above 100 ing·L-1 remain suspended in streams inhabited by juvenile Arctic grayling or other sensitive fish species for extended periods. Suspended sediment strengths as low as 100 mg·L-1 may also prove harmful to the long-term well-being of grayling in natural stream environments. Although the effects on growth and feeding response times for fish exposed to 100 mg·L-1 sediment for 6 weeks were minimal, the absence of a continuous supply of excess food in the natural environment together with the greater effort required for the detection and capture of available food, predator/prey inter- actions and simultaneous exposure to other less-than-optimal environ- mental conditions may increase the impact of prolonged exposure to this suspended sediment strength. The displacement of salmonid fish from upstream waters shown in this study for suspended sediment strengths greater than 100 mg·L-1 and in a previous (Sigler 1981) laboratory investigation where stream turbidity was 40 -50 NTU is of particular concern, as these findings indicate that short~term pulses of suspended sediment may cause downstream migration of otherwise resident fish. This downstream displacement and probable reduction in the amount and quality of living r l r [ l [ [ I L I L [ [ [ [ [ r· r L [ . E [ r I = IL> -29 - space are cause for concern. Clarification of the effects of suspended sediment on fish displacement and avoidance/preference responses under natural and controlled environmental conditions is desirable. A better understanding of the influence of sediment type (particle shape and size) and concentration on fish behaviour, stress responses and energetics should also be achieved. ACKNOWLEDGEMENTS We wish to acknowledge the co-operation of the ·placer miners along Highet Creek, Yukon. The provision of placer mining sediment and logistics support by Mr. S. Howe and Ms. M. Jack (Department of Indian and Northern Development), fish by Messrs. R. Elvidge, B. Anderson and A. VonFinster (Fisheries and Oceans Canada), .and fruit flies by the Department of Zoology, University of B. C. is gratefully acknowledged. We wish to thank Messrs. J. Kong and H. Wong for their daily effort, dedication and input during all aspects of these laboratory bioassays. Our thanks are also expressed to the Environment Canada/Fisheries & Oceans laboratory staff at West Vancouver for their analytical services, and to B.C. Research (Vancouver) for. the use of their fish rearing/test facilities and for sediment preparation and analysis. Drs. D.J. Randall (Department of Zoology, University of B.C.) and J.G. Malick (Norecol Environmental Consultants Ltd.) kindly provided assistance with data interpretation. The technical assistance of Ms. S. Jones (drafting) and Ms. D. Henn (typing) is also acknowledged with thanks. -30 - REFERENCES Alderdice, D.F,. 1963. Some effects of simulataneous variation in salinity, temperature and dissolved oxygen on the resistance of juvenile coho salmon (Oncorhynchus kisutch) to a toxic substance. Ph.D. Thesis. Univ. of Toronto~ 177 pp. Anon. 1965. Water quality criteria for European freshwater fish. Report on finely divided solids and inland fisheries. European Inland Fisheries Advisory Committee. Int. J. Air Wat. Poll. 9: 151-168. Anon. 1972. Testing Sieves and Their Uses. Handbook 53. W.S. Tyler Inc. Mentor, Ohio. 48 pp. Anon. 1979. Environmental Laboratory Manual. Environment Canada and Fisheries & Oceans Canada. West Vancouver. Anon. 1980. Standard Methods for the Examination of Water and Wastewater. 15th edition. American Public Health Association, American Water Works Association and Water Pollution Control Federation. Washington, D.C. 1134 pp. Anon. 1983. A Rationale for the Suspended Solids Standards for Yukon Streams Subject to Placer Mining. Paper prepared by Fisheries & Oceans and Environment Canada. February 1983. New Westminster, B. C. 24 pp. Berg, L. 1982. The effect of exposure to short-term pulses of suspended sediment on the behavior of juvenile salmon ids. pp. 177-196. In Proceedings of the Carnation Creek Workshop: A Ten-Year Review. G.F. Hartman, ed. February 24-26, 1982. Birtwell, I.K., G. Hartman, B. Anderson, D.J. McLeay and J.G. Malick. 1984. A brief investigation of Arctic grayling (Thymallus arcticus) and aquatic invertebrates in the Minto Creek drainage, Mayo, Yukon Territory. Can. Tech. Rep. Fish. Aquat. Sci. (In Pre.). Black, E.C. 1953. Upper lethal temperatures of some British Columbia freshwater fishes. J. Fish. Res. Bard Can. 10: 196-210. Brett, J .R. 1952. Oncorhynchus. Temperature tolerance in young Pacific salmon, genus J. Fish. Res. Board Can. 9: 265-323. Brett, J.R. 1958. Implications and assessments of environmental stress. pp.· 69=83. In The Investigations of Fish-Power Problems (P.A. Larkin, ed.). MacMillan Lectures in Fisheries, Univ. of B.C. Vancouver. [ [ [ [ [ [" L [ [ b [ r~ l:::l [ L r~ L -31 - Brett, J.R. 1971. Energetic responses of salmon to temperature. A study of some thermal relations in the physiology and freshwater ecology of sockeye salmon (Oncorhynchus nerka). Am. Zool. 11: 99- 113. Brett, J.R. 1976. Scope for metabolism and growth of sockeye salmon, Oncorhynchus nerka, and some related energetics. J. Fish Res. Board Can. 33: 307-313. Brett, J.R., J.E. Shelbourn and C.T. Shoop. 1969. Growth rate and body composition of fingerling sockeye salmon, Oncorhynchus nerka, in relation to temperature and ration size. J. Fish. Res. Board Can. 26: 2363-2394. Campbell, H.J. 1954. The effect of siltation from gold dredging on the survival of rainbow trout and eyed eggs in Powder River, Oregon. Oregon State Game Comm. Report. 3 pp. Carlander, K.D. 1969. Handbook of Freshwater Fishery Biology. Iowa State Univ. Press, Ames. 75 pp. Crouse, M.R., C.A. Callahan, K.W. Malueg, and S.E. Dominguez. 1981. Effects of fine sediments on growth of juvenile coho salmon in laboratory streams. Trans Amer. Fish. Soc. 110: 281-286. Davis, J.C. 1975. Minimal dissolved oxygen requirements of aquatic life with emphasis on Canadian species. A review. J. Fish. Res. Board Can. 32: 2295-2332. Davis, J.C. and R.A.W. Hoos. 1975. Use of sodium pentachlorophenate and dehydroabietic acid as reference toxicants for salmonid bioassays. J. Fish. Res. Board Can. 32: 41-416. Ennis, G.L., A. Cinader, S. Mcindoe and T. Munsen. 1982. An annotated bibliography and information summary on the fisheries resources of the Yukon River Basin in Canada. Can. Ms. Rep. Fish. Aquat. SoL 1657. 278pp. Gordon, M.R. and D.J. McLeay. 1977. Sealed-jar bioassays for pulpmill effluent toxicity: effects of fish species and temperature. J. Fish. Res. Board Can. 34: 1389-1396. Gradall, K.S. and W.A. Swenson. creek chubs to turbidity. 395. 1982. Responses of brook trout and Trans. Amer. Fish. Soc. 111: 392- Griffin, L.E. 1938. Experiments on the tolerance of young trout and salmon for suspended sediment in water. Bull. Ore. Dept. Geol. 10: 28-31. Herbert, D.W.M. and J.M. Richards. 1963. The growth and survival of -32 - fish in some suspensions of solids of industrial origin. Int. J. Air Wat. Poll. 7: 297-302. Herbert, D.W.M. and J.C. Merkens. 1961. The effect of suspended mineral solids on the survival of trout. Int. J. Air WWat. Poll. 5: 46-55. Herbert, D.W.M., J.S. Alabaster, M.C. Dart and R. Lloyd. 1961. The effect of china-clay wastes on trout streams. Int. J. Air Wat. Poll. 5: 56-75. Holeton, G.F. and D.J. Randall. 1967. The effect of hypoxia upon the partial pressure of gases in the blood and water afferent and efferent to the gills of rainbow trout. J. Exp. Biol. 46: 317- 327. Leitritz, E. and R.C. Lewis. 1976. Trout and Salmon Culture: Hatchery Methods. Calif. Dep. Fish & Game. Fish Bull. 164. Litchfield, J.T. 1949. cent effect curves. A method for rapid graphic solution of time-per J. Pharmacol. Exp. Therap. 97: 399-408. McLeay, D.J. 1976. A rapid method for measuring the acute toxicity of pulpmill effluent and other toxicants to salmonid fish at ambient room temperature. J. Fish. Res. Board Can. 33: 1301-1311. McLeay, D.J. 1977. Development of a blood sugar bioassay for rapidly measuring stressful levels of pulpmill effluent to salmonid fish. J. Fish. Res. Board Can. 23: 2164-2175. McLeay, D.J. and D.A. Brown. 1974. Growth stimulation and biochemical changes in juvenile coho salmon (Oncorhynchus kisutch) exposed to bleached kraft pulpmill effluent for 200 days. J. Fish. Res. Board Can. 31: 1043-1049. McLeay, D.J. and M.R. Gordon. technique for measuring stressful concentrations Can. 34: 2164-2175. 1977. Leucocrit: a simple hematological acute stress in salmonid fish, including of pulpmill effluent. J. Fish. Res. Board McLeay, D.J. and M.R. Gordon. 1980. Short-term sublethal toxicity tests to assess safe levels of environmental contaminants. B. C. Research Proj. Report No. 1-11-199. Prepared for Environment Canada. Vancouver. 24 pp. McLeay, D.J. and T.E. Howard. 1977. Comparison of rapid bioassay procedures for measuring toxic effects of bleached kraft mill effluent to fish. pp. 141-155. In Proc. 3rd Aquat. Tox. Workshop, Halifax, N.S. Nov. 2-3, 1976. Envir. Prot. Serv. Tech. Rep. No. EPS-5-AR-77-1. Halifax. l l [ l [ l [ I L [ '- [ [ r L [ c [ [ r L -33 - McLeay, D.J., A.J. Knox, J.G. Malick, I.K. Birtwell, G. Hartman, and G.L. Ennis. 1983. Effects on Arctic grayling (Thymallus arcticus) of short-term exposure to Yukon placer m1n1ng sediments: laboratory and field studies. Can. Tech. Rep. Fish. Aquatic Sci. 1171. 134 pp. Mathers, J .s., N.O. West, and B. Burns. 1981. Aquatic and wildlife resources of seven Yukon streams subject to placer mining. Government of Canada, Departments of Fisheries and· Oceans, Indian and Northern Affairs, and Environment. 183 pp. Noggle, C.C. 1978. Behavior, physiological and lethal effects of suspended sediment on juvenile salmonids. M.S. Thesis. Univ. Washington 87 pp. O'Brien, W.J., C. Buchanan and J.F. Haney. 1979. Arctic zooplankton community structure: exceptions to some general rules. Arctic 32: 237-247. O'Connor, J.M., D.A. Neumann and J.A. Sherk, Jr. 1977. effects of suspended sediments on estuarine fish. Solomons Nat. Res. Inst. Publ. No. CERC-TP-77-3. Sublethal Maryland Univ. 92 pp. Randall, D.J. 1970. Gas exchange in fish. pp. 253-292. In Fish Physiology. Vol. IV. W.S. Hoar and D.J. Randall, eds. Academic Press, N.Y. Redding, J.M. and C.B. Schreck. 1980. Chronic turbidity and stress in juvenile coho salmon and steelhead trout. Pac. N. W. For. Lab. Report PNW-1705-16. Final report. June 13, 1980. 84 pp. Corvallis, Oregon. Schmidt, D. and W.J. O'Brien. 1982. Planktivorous feeding ecology of Arctic grayling ( Thymallus arcticus). Can. J. Fish. Aquatic Sci. 39: 475-482. Selye, H. 1950. Stress. Acta Inc., Montreal. 822 pp. Sherk, J.A., J.M. O'Connor, D.A. Neumann, R.D. Prince and K.V. Wood. 1974. Effects of suspended and deposited sediments on estuarine organisms -Phase II. Final report. 299 pp. Nat. Res. Inst., Univ. Maryland. Sigler, J.W. 1981. Effects of chronic turbidity on feeding, growth and social behavior of steelhead trout and coho salmon. Ph.D. Thesis. Univ. Idaho. 169 pp. Soivio, A., K. Westman and K. Nyholm. 1974a. Changes in haematocrit values in blood samples treated with and without oxygen: a comparative study with four salmonid species. J. Fish Biol. 6: 763-769. -34 - Soivio, A., K. Westman and K. Nyholm. 1974b. The influence of changes in oxygen tension on the haematocrit value of blood samples from asphyxic rainbow trout (Salmo gairdneri). Aquaculture 3: 395-401. Sprague, J.B. 1973. The ABC's of pollutant bioassay using fish. pp. 6- 30. In Biological Methods for the Measurement of Water Quality. ASTM STP 528. American Society for Testing Materials. Philadelphia, PA. Warren, C.E. and G.E. Davis. 1967. Laboratory studies on the feeding bioenergetics and growth of fish. pp. 175-214. In S.D. Gerking (ed.) The Biological Basis for Freshwater Fish Populations. Blackwell Scientific Publications, Oxford. Webb, P.W. and J.R. Brett. 1972. The effects of sublethal concentrations of whole bleached kraftmill effluent on the growth and food conversion efficiency of underyearling sockeye salmon (Oncorhynchus nerka). J. Fish. Res. Board Can. 29: 1555- 1563. Webb, P.W. and J.R. Brett. 1973. Effects of sublethal concentrations of sodium pentachlorophenate on growth rate, food conversion efficiency, and swimming performance in underyearling sockeye salmon (Oncorhynchus nerka). J. Fish. Res. Board Can. 30: 499- 507. Wedemeyer, G.A. and D.J. McLeay. 1981. Methods for determining the tolerance of fishes to environmental stressors. pp. 247-275. In Stress and Fish. A.D. Pickering, ed. Academic Press. London. Wedemeyer, G.A., D.J. McLeay and C.P. Goodyear. 1983. Assessing the tolerance of fish and fish populations to environmental stress: the problems and methods of monitoring. In Advances in Environmental Science and Technology. Wiley and Sons, Toronto. In press. Zar, J.H. 1974. Biostatistical Analysis. Prentice-Hall Inc., Englewood Cliffs, N.J. [ r L, r L [ [ [ [ [ L r : L ~­U,i I ;l1i[l\ TABLE 1.Particle size distribution for test sediment collected from a placer mine settling pond. Untreated sedimenta Sieve size (mesh) Particle size (um) Weight (%) Cumulative weight (%) Prepared Sample no.1 Weight Cumulative (%)weight (%) sedimentb Sample Weight (%) no.2 Cumulative weight (%) +35 >400 0.0 0.0 0.0 0.0 0.0 0.0 +48 >300 0.0 0.0 0.0 0.0 0.0 0.0 w +65 >210 0.1 0.1 0.0 0.0 0.0 0.0 U'1 +100 >150 0.4 0.5 0.0 0.0 0.1 0.1 +150 >100 3.3 3.8 0.2 0.2 0.1 0.2 +200 >75 17.1 20.9 2.3 2.5 1.6 1 .8 +325 >45 40.6 61.5 16.8 19.3 16.5 18.3 +400 >38 15.7 77.2 10.0 29.3 11.9 30.2 -400 <38 22.8 100.0 70.7 100.0 69.8 100.0 a Surficial sediment as collected from the downstream end of a de-watered settling pond. bOven-dried (500 C)and pulverized (Vibratory ring pulverizer)for 2 min. -36 - TABLE 2.Oxygen uptake rate,volatile and fixed residue for test sediment collected from a placer mine settling pond. Characteristic Sample no.1 Sample no.2 oxygen uptake rate at 150C 0.01 0.01 (mg °2·g-1 dry sediment·24h-1 ) oxygen uptake rate at 150C 0.01 0.01 (mg °2·ml -1 dry sediment·24h-1 ) volatile residue (%)5.4. fixed residue (%)95.96 .. [' [ r~ L [ [ [ L G [ [ L rL [ 6 C [ C [ L L L -37 - TABLE 3.Metal contenta for test sediment collected from q placer mine settling pond. Concentration (ug'g-1 dry weight) Component Sample no.1 sample no.2 arsenic As 653.649. barium Ba 341.344. beryllium Be 0.6 0.6 cadmium Cd 0.3 0.3 cobalt Co 12.2 12.0 chromium Cr 56.1 41.8 copper Cu 39.4 37.5 manganese Mn 705.705. molybdenum Mo 4.6 2.3 nickel Ni 25.25. phosphorous P 720.726. lead Pb 13.11 • tin Sn 2.0 2.0 strontium Sr 36.4 36.6 titanium Ti 649.632. vanadium V 45.44. zinc Zn 81.6 82.0 aluminum Al 20700.20800. iron Fe 40300.40100. silicon Si 4400.5160. calcium Ca 3770.3710. magnesium Mg 5510.5540. sodium Na 420.390. aBased on analysis of sediment digest by inductively coupled argon plasma spectrograph (Anon.1979). -38 - TABLE 4.Effect of stream position on suspended sediment strength. Nominal sediment strength Stream Stream position _._._---- (mg·L-1)no.Upstream Midstream Downstream 0 4 <Sa <Sa <Sa 0 8 <S <5 <5 100 2 95 97 91 100 5 111 98 110 300 3 308 305 316 300 6 318 308 310 1000 1 1030 1020 1030 1000 7 997 1010 1000 aNonfiltrable residue values determined for grab samples collected concurrently at mid-depth. r-' l~ [ [ [ C L [ L ,- L I' L r:rr-JI r---, L. TABLE 6.Weekly mortalities of underyearling Arctic graylinga in test streams during prolonged exposure to dHfering strengths of placer mining sediment. Duration of exposure (weeks) _______________-'-N,o~m=in:.::;a=.;l"___'s;;...;t=r~ngth of su spended o (control)100 Stream 4 St:"::r:'<"e-am---=8c-Stream 2 Stream 5 Mb DC M D M D M D sediment (mg.L-1) 300 Stream 3.Stream 6 M D M D 1000 Stream 1 Stream 7 M D M D Od 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 2 0 3 0 0 0 0 0 2 0 3 0 5 0 0 0 0 2 2 0 2 0 3 e 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 0 0 0 0 0 0 0 0 0 0 0 2 0 +:> 0 6 0 0 0 0 0 0 0 0 2 0 0 0 0 0 totalf 5 8 3 5 3 6 7 3 a Sixty fish added initially to each of eight test streams. b Fish missing;presumed dead. c Fish dead;examined for lesions. d During the initial 7-day period for acclimation of fish to test streams. e Ten fish removed from each stream for pentachlorophenol bioassays. f Combined value for missing and/or dead fish in each stream throughout the test period. ,~ rm r----"1lJ ( TABLE 7.Weekly weights for groupsa of underyearling Arctic grayling exposed for 6 weeks to differing strengths of suspended placer mining sediment. Duration Nominal strength of suspended sediment (mg·L-1) of exposure o (control)100 300 1000 (weeks)Steam 4 Stream 8 Stream 2 Stream 5 Stream 3 Stream 6 Stream 1 Stream 1 Ob 0.41 d 0.41 0.40 0.42 0.41 0.42 0.44 0.40 (0.09)(0.08)(0.08)(0.09)(0.08)(0.09)(0.09)(0.09) oc 0.55 0.53 0.53 0.54 0.52 0.52 0.53 0.56 (0.12)(0.11)(0.11)(0.10)(0.10)(0.11)(0.11) (0.10) 0.64 0.64 0.62 0.61 0.62 0.63 0.59 0.66 (0.18)(0.15)(0.15)(0.15)(0.14)(0.15) (0.14)(0.14) 2 0.80 0.11 0.15 0.80 0.14 0.11 0.68 0.15 (0.25)(0.18)(0.18)(0.18)(0.18)(0.11)(0.18)(0.17) 3 0.91 0.96 0.86 0.94 0.85 0.91 0.14 0.83 ~...... (0.31)(0.24)(0.22)(0.23)(0.22)(0.20)(0.19) (0.19) 4 1.11 1.13 0.98 1.10 0.99 1.08 0.84 0.96 (0.36)(0.30)(0.24-)(0.28)(0.21 )(0.26)(0.21)(0.20) 5 1.28 1.31 1.13 1.22 1.13 1.24 0.94 1.05 (0.42)(0.35)(0.29 )(0.35)(0.36)(0.32)(0.20) (0.24) 6 1.40 1.39 1.30 1.38 1.30 1.33 1.01 1.18 (0.49)(0.41)(0.37)(0.45)(0.44)(0.35)(0.25)(0.28) a Sixty fish added initially to each of eight test streams. b Upon addition of fish to test streams. c Following a 1-day period for acclimation of fish to test streams. d Mean weigh1~(g),with standard deviation in parenthesis. TABLE 8.PercEmtage distribution of underyearling Arctic grayling in four equal portions of each test stream following exposure of fish to suspended placer mining sediment for 4 or 5 weeks. Duration of Stream Nominal strength of suspended sediment (mg·L-1) exposure position o (control)100 300 1000 (weeks)(quarter)Stream 4 Stream 8 Stream 2 Stream 5 Stream 3 Stream 6 Stream 1 Stream 7 4 1 11 a 48 6 6 2 2 0 2 2 37 38 40 7 10 13 15 10 3 15 12 27 40 53 40 15 48 4 37 2 27 47 35 45 70 40 5 1 0 7 12 2 2 7 2 4 2 59 38 34 18 4 18 14 15 3 37 55 28 11 55 32 36 49 4 4 0 26 69 43 48 ~39 32 N 4 +5 1 6 27 9 4 2 4 1 3 (mean)2 48 38 37 13 7 16 15 13 3 26 34 27 26 54 36 26 48 4 20 1 27 57 37 44 58 36 4 +5 1 +2b 54 66 46 17 9 20 16 16 (mean)3 +4C 46 34 54 83 91 80 84 84 apercentage of fish occupying stream position indicated. bUpstream half of test stream. cDownstream half of test stream. _I ..t Iir,r--:,..,J ,...--... ,"j IJ ,-------, l J TABLE 9.Effect of differing strengths of suspended placer m~n~ng sediment on the feeding response to surface drift (Drosophila melanogaster)for underyearling Arctic grayling held in test streams for 5 weeks. Feeding response time (seconds)C Trial Replicate o (control)~~L-1 Sediment 300 mg.L-1 Sediment 1000 mg·L-1 Sediment no.a no.b Stream 4 Stream 8 Stream 2 Stream 5 Stream 3 Stream 6 Stream 1 Stream 7 1 10 6 45 26 40 143 166 >360 2 5 7 5 40 80 60 40 115 3 7 7 21 25 30 47 150 46 4 7 6 17 34 17 87 198 140 5 7 5 10 19 17 75 48 296 mean 7 6 20 29 37 82 120 >191 (SO)2 1 15 8 26 37 72 (>131) 2 1 4 6 15 13 28 23 184 22 2 5 5 15 39 20 13 115 32 3 6 6 8 39 21 10 19 15 4 6 6 20 18 30 10 92 43 5 5 8 20 40 19 43 >360 23 6 9 5 20 21 45 20 >360 21 .j:::o w7861553102632221 mean 6 6 16 32 38 26 >165 25 (SO)2 1 4 15 30 20 (>145)9 3 1 9 13 31 49 26 45 88 22 2 8 8 8 35 23 22 49 82 3 10 6 15 26 82 12 145 45 4 5 7 15 31 18 68 61 40 5 6 8 10 14 20 12 60 24 6 6 7 26 10 26 18 59 55 7 5 7 7 18 21 10 22 21 8 11 6 22 31 15 21 90 21 9 16 8 6 28 23 9 44 238 mean 8 8 16 27 28 24 69 61 (SO)4 2 9 12 20 20 35 69 a Each trial conducted with 3 fish selected randomly from the test stream. b Test rep,eated using same 3 fish. c Time for fish to consume a live fruit fly placed on stream surface 60 cm upstream from fish. TABLE 10.Effect of d.iffering strengths of suspended placer mining sediment on the feeding response to surfaee drift (Drosophila melanogaster)for underyearling Arctic grayling held in test streams for 1 hour prior to testing. Feeding response time (seconds)C 1000 mg.L-1 SedimentTrialReplicateo(control)100 mg.L-1 Sediment 300 mgoL-1 Sediment no.a no.b Stream 4 Stream 8 Stream 2 Stream 5 Stream 3 Stream 6 Stream 1 Stream 7 1 19 7 >360 >360 >360 285 >360 45 2 6 11 13 24 >360 175 >360 209 3 4 19 74 11 >360 156 >360 288 4 26 9 72 21 50 54 >360 >360 5 4 6 14 14 >360 13 >360 160 mean 12 10 >107 >86 >298 137 >360 >213 (SD)10 5 145 153 139 107 0 121 -l:=> 2 1 21 85 >360 260 >360 320 >360 360 -l:=> 2 12 31 226 100 80 29 310 360 3 10 27 17 206 >360 187 >360 342 4 5 5 23 47 114 43 >360 360 5 6 6 10 16 18 37 >360 360 6 4 6 21 28 85 27 >360 360 7 12 12 21 20 69 14 >360 360 mean 10 25 >97 97 >155 94 >353 >357 (SD)6 29 140 98 143 116 19 7 a Ealch trial conducted with .3 fish selected randomly from the outside rearing tank. b Test repeated using same 3 fish. c Time for fish to consume a live fruit fly placed on stream surface 60 cm upstream from fish. TABLE 11.Effect of differing strengths of suspended placer m~n~ng sediment on the feeding response to sub-surface drift (Artemia salina)for underyearling Arctic grayling held in test streams for 6 weeks. Total no.of brine shrimp consumed (n=10)CObservation._--'--:-_._ Trial time 0 (control)100 mg.L-1 Sedimen~300 mg.L-1 Sediment 1000 mg.L-1 Sediment no.a (min)b Stream 4 Stream 8 Stream 2 Stream 5 Stream 3 Stream 6 Stream 1 Stream 7 2 3 1 3 5 10 15 30 45 60 1 3 5 10 15 30 45 60 1 3 5 10 15 30 45 60 Reponse time (min)d 8 10 4 8 10 6 9 10 4 <3-5) 7 10 8 10 7 10 3 8 10 5 10 6 10 3 5 10 4 8 10 10 3 (1-5) 4 7 9 10 5 7 9 10 7 10 8 (3-10) 5 10 8 9 10 5 10 4 (3-5) o o o o o 1 7 8 o o o o o o o o o 1 1 1 2 2 3 4 60 1 1 2 3 3 6 6 6 1 1 3 4 4 5 5 7 1 1 1 1 1 2 2 2 60 a Each trial conducted with 3 fish selected randomly from the test stream. b Baskets raised at fixed time intervals in order to count no.of brine shrimp uneaten. c Ten live brine shrimp placed in a nylon-mesh basket submersed in the test stream,and fish introduced at time O. d Mean time to consumption of all brine shrimp (range in parentheses). TABLE 12.Effect of differing strengths of suspended placer mining sediment on the feeding response to a benthic invertebrate (tubificid worms)for underyearling Arctic grayling held in test streams for 5 weeks vs.1 hour prior to testing. Duration Total no.of worms consumed (n=10)CofObservation sediment Trial time o (control)100 mg.L-1 Sediment 300 mg.L-1 Sediment 1000 mg.L-1 Sediment exposure no.a (min)b Stream 4 Stream 8 Stream 2 Stream 5 Stream 3 Stream 6 Stream 1 Stream~ 5 weeks 1 6 6 6 7 5 8 0 0 3 6 7 7 9 8 10 0 0 5 7 8 8 10 9 0 0 10 9 10 9 10 0 0 15 10 10 0 0 30 1 0 45 1 0 60 1 0 5 weeks 2 1 5 3 3 4 8 7 0 0 3 7 6 3 10 10 8 0 0 5 8 8 9 8 0 0 10 10 9 10 10 0 0 15 10 0 0 30 0 0 45 0 0 60 0 0 5 weeks 3 1 6 8 8 9 0 7 0 0 3 10 10 10 10 0 8 0 0 .r::- 5 4 10 0 0 0"1 10 9 0 0 15 10 0 0 30 1 0 45 1 0 60 1 0 Response time 9 9 9 4 9 6 >60 >60 (min)d (3-15)(3-15)(3-15 )(3-5)(3-15)(3-10) hour 1 8 7 4 1 5 8 0 0 3 9 9 4 8 7 10 0 0 5 10 10 6 10 10 0 0 10 10 0 0 15 0 0 30 0 0 45 0 0 60 0 0 Response time 5 5 10 5 5 3 >60 >60 (min)d a Each trial conducted with 3 fish selected randomly from the test stream/outside tank. b Baskets raised at fixed time intervals in order to count no.of worms uneaten. c Ten live tubifex worms placed in a nylon-mesh basket submersed in the test stream,and fish introduced at time O. d Mean time to consumption of all worms (range in parentheses). '~l-~J'-.~I •j ~l.." TABLE 13.Length,weight,and condition factor of underyearling Arctic grayling following exposure to differing strengths of suspended placer mining sediment for 3 or 6 weeks. Nominal Duration of sediment Fish length Fish weight Condition factor exposure strength Stream No.of (cm)(g)(K) (weeks)(mg.L-1)no.fish Mean SD Mean SD Mean SD 3 0 4 10 4.8 0.5 0.99 0.28 0.86 0.07 0 8 10 4.8 0.6 1.01 0.34 0.86 0.11 100 2 10 4.8 0.3 0.93 0.23 0.83 0.05 100 5 10 4.9 0.4 1.13 0.29 0.96 0.07 300 3 10 4.9 0.2 1.00 0.20 0.85 0.07 .j::> 300 6 10 4.8 0.5 1.07 0.29 0.95 0.07 '-l 1000 1 10 4.6 0.4 0.82 0.22 0.82 0.05 1000 7 10 4.6 0.3 0.95 0.24 0.96 0.08 6 0 4 45 5.4 0.6 1.40 0.49 0.85 0.10 0 8 42 5.5 0.5 1.39 0.41 0.81 0.11 100 2 47 5.2 0.5 1.30 0.37 0.90 0.11 100 5 45 5.3 0.5 1.38 0.45 0.89 0.09 300 3 47 5.2 0.5 1.30 0.44 0.92 0.11 300 6 44 5.3 0.5 1.33 0.35 0.88 0.09 1000 1 43 4.9 0.4 1.01 0.25 0.83 0.11 1000 7 47 5.1 0.4 1.18 0.28 0.88 0.08 TABLE 14.Biological characteristics determined for underyearling Arctic graylinga following exposure to different strengths of suspended placer mining sediment for 6 weeks. Nominal strength of suspended sediment (mg.L-l) Variable Statistic o (control) Stream 4 Stream 8 100 Stream 2 Stream 5 300 Stream 3 Stream 6 1000 Stream 1 Stream 7 length (cm) weight (g) condition factor (K) body moisture (%") hematocrit (%) leucocrit (%) plasma ~lucose (mg%) mean SD mean SD mean SD mean SD mean SD mean SD mean SD 5.1 0.6 1.18 0.41 0.84 0.08, 77 1 34 7 1.0 0.4 62 8 5.5 0.4 1.31 0.27 0.78 0.09 78 1 30 3 1.0 0.2 60 12 5.2 0.4 1.19 0.25 0.85 0.10 78 1 36 5 0.9 0.2 68 7 5.3 0.5 1.25 0.35 0.82 0.06 77 1 29 5 1.0 0.2 58 7 5.2 0.3 1.18 0.24 0.82 0.05 77 2 35 6 0.9 0.1 67 8 5.4 0.3 1.36 0.29 0.85 0.05 77 2 31 4 1.0 0.2 62 7 5.0 0.5 0.98 0.26 0.78 0.06 79 1 28 4 1.0 0.2 57 8 5.0 0.5 1.05 0.34 0.80 0.07 78 1 30 5 0.9 0.2 59 6 a Values determined for groups of 10 fish sampled randomly from each test stream. -.-', J -,i'I:1 [-j TABLE '15._Acute lethal tolerance of underyearling Arctic grayling to the reference toxicant pentachlorophenol following ex~osure to differing strengths of suspended placer mining sediment for 3 weeks. aDetermined by exposing groups of 10 fish to 30-L volumes of pentachlorophenol dissolved in clear (NFR <5 rngoL-1)freshwater. bLethal time to 50%mortality of test fish. C95%confidence interval. ·Pooled value for treatment differs significantly (P <0.05)from that for controls. TABLE 16.Acute lethal tolerance of underyearling grayling to the reference toxicant pentachlorophenol following exposure to differing strengths of suspended placer mining sediment for 6 weeks. Suspended sediment Fish weight Time to death (min)in strength Stream (.&L-_150 ug·L-1 pentachlorophenola (mg.L-1)no.Mean 3D LT50 b 95%CIe 0 4 1.46 0.47 285 261-311 0 8 1.57 0.55 310 258-372 100 2 1.24 0.37 302 288-317 (J1 100 5 1.32 0.48 300 283-318 0 300 3 1.53 0.53 265*234-299 300 6 1.42 0.49 235*208-266 1000 1 0.91 0.22 260*226-299 1000 7 1•11 0.20 265'250-281 aDetlarmined by exposing groups of 10 fish to 30-L volumes of pentachlorophenol dissolved in clear (NFR <5 mg.L-1)freshwater. bLethal time to 50%mortality of test fish. e95%confidence interval. *Pooled value for treatment differs significantly (P <0.05)from that for controls. l:,.r:-l ,-------, J TABLE 11.Response of underyearling Arctic grayling to hypoxiaa following exposure to differing strengths of suspended placer mining sediment for 6 weeks. Time to death (min) Suspended sediment strength (mg·L-l) Stream no" Fish weight -(g) Mean SD LT50 h 95%crc Residual oxygen at death (mg02·L-1) Mean SD Range 0 4 1.28 0.30 141 134 -162 2.1 0.5 1.8 -3.2 0 8 1.11 0.21 158 140 -179 2.9 0.2 2.4 -3.2 <.J"1 145 134 - .....100 2 1.29 0.31 157 2.7 0.3 2.2 -3.0 100 5 1.28 0.17 145 134 -157 2.4 0.3 2.0 -3.2 300 3 1.25 0.35 125·113 -139 3.1 0.5 2.3 -3.9 300 6 1.45 0.24 115·106 -124 2.9 0.8 2.1 -4.5 1000 1 1.15 0.20 125*112 -140 3.2 0.4 2.6 -3.6 1000 7 1.29 0.34 125·116 -135 2.6 0.4 2.2 -3.5 aDetermined by sealed jar bioassays (n =10 )with test suspensions at 20 oc. bLethal time to 50%mortality of test fish. C95%confidence interval. ·Pooled value for treatment differs significantly (P <0.05)from that for controls. TABLE 18.UppElr lethal temperature tolerance of underyearling Arctic grayling following exposure to differing strengths of suspended placer mining sediment for 6 weeks. Suspended Acclimation temperaturea Temperature at death b sediment Sample (oC)(°C) strength Stream size (mg·L-1 )no.(n)Mean SD Mean SD Range 0 4 15 15.2 0.4 27.7 0.3 26.9 -28.2 0 8 8 14.0 0.4 27.0 0.7 26.0 -27.7 100 2 17 15 •.1 0.3 27.7 0.3 26.8 -27.9 (Jl N 100 5 15 15.6 0.4 27.9 0.3 27.2 -28 .•1 300 3 17 15.4 0.4 28.0 0.2 27.8 -28.2 300 6 14 15.1 0.4 27.7 0.1 27.5 -28.1 1000 1 9 14.9 0.4 27.7 0.1 27.6 -27.8 1000 7 17 14.9 0.6 27.8 0.2 27 .6 -28.0 aBased on dai.ly record of water temperature in each test stream. bDetermined by increasing the temperature of each suspension at 10 C·h-1 until all fish were dead. ~r:..---f ~.'r-J r:-J r-J r:-J nTT r-}r:-:l r--:-J LTJ ~i-~.--,~I I I .j I J I l"___,..__-3 I J J -53 - -54 - Figure 1.Illustration of test streams showing reservoir barrels, barrel stirrers,peristaltic pumps for dispensing sedimen~suspensions,recycle pumps and air supply. [ [ [ [ [ r L [ [ [ L.;tJ [ [ l Compressed Air Supply r--:L ,j Removable Screen Partition Screen Partition Emeroency OxYoen Peristaltic Pump --t»dJPP (70 mi·min -I per strl8am 8 51;""~PP(l700rpm)~==~ g ~20·L Capacity Reservoir Barrel /0 em ,'"-:' I , ~~~~~'f---T:~~~~~~:-:if"'--- -r- 20cm '+-I1------------2/0cm------------- Four Pumps Four Pumps -56 - Figure 2.Relationship of nonfiltrable residue (NFR)concentration of placer mining sediment added to barrel vs.suspended sediment strength within test streams. [ [ C [ [ [ [ r L r- L ~-------_.-._--._--- 5000 z 40000 ~ Q: to- Z Wu-3000z- 0' u..J ..JCt 1TIWE-....J Q:- Q:2000 <tQ: mLL Z ..J LEGEND<tLL ZO *End of stream::IE 1000 0 o Middle of streamZ 0~--1.~-L_...1.-----JL..---L_-L-_.L---1_--L._~_.L----L_~_...L----IL.----'-_....I-_..L------I_""'" o 100 200 300 400 ~oo 600 700 800 900 1000 NFR IN TEST STREAMS (mg·L -I) -58 - Figure 3.Illustration of daily fluctuations in concentration of nonfiltrable residue within each test stream throughout the 6-week exposure period. r~ L [ [ [ [ L [ L, L r- L L r-J,:-l, Stream I Stream 7 ...._----..... "''''----_/ Stream 6 Stream 3 --Stream 4 14 ", CONTROLS <5 21 Stream 8 ••- •- 28 35 , 42 Strtlam 5 Stream 2 EXPOSURE (days) -60 - Figure 4.Illustration of daily fluctuations in turbidity within each test stream throughout the 6-week exposure period. ! L I I IL ! L [ [ [ [ C C [ [ ( L I' L 0'1...... 42 Str~am I .....Stream 7 352821 ,",.....-.---..-----••---••:;';.;';.;-;.:':;.:.-::•.:.;-;-:.:.a...._,,;.'.:',;,'-'-"-.----"'----:,:-:;-:;-::;-:.:-.:.-_ CONTROLS <3 I 147 ,,-...--..------- 2200 2000 1800 1600 ;:) t-1400 -'I.L-1200 >-t- O 1000 ma:: :::>800 t- 600 400 200 0 EXPOSURE (days) Figure 5. -62 - Effect of suspended placer mlnlng (weekly wet weight gain)of grayling.Mean values for each together with the 95%confidence only. sediment on the growth underyearling Arctic treatment are shown, intervals at 6 weeks r [ r L [ [ C C rc [ [ r: L r~ L L 65 LEGEND Nominal strength of suspended sediment (mg·L-I) o 0 (control) •100 x 300 l:>.1000 1 2 3 4 DURATION OF EXPOSURE (weeks) o 60 fish added to each of 8 test streams (120 fish per treatment) sediment added (after I week ac~limation ) 0.7 0.9 0.3 -63 - 0.6 0.2 0.4 0.5 0.8 0.1 0.0 I__L..--_....L..----L-----L--_-.--L-_--I.-_---J...--_ o 1.1 1.0 1.2 1.4 1.3 1.5 L L ~ - L - [ [ L nL, r -L Ot- .-~-t-L :I: (!) W.~~- 6 C C [ A L r'L I - I - ~ [ -64 - Figure 6.Illustration of effect of differing strengths of suspended placer mining sediment on feeding response for underyearling Arctic grayling held in test streams for (a)5 weeks or (b)1 hour prior to testing.Bars repr~sent mean values for separate trials,and broken ex~ tensions of bars represent "greater than"values. [' [ [ [ [ r l~ [: [ c [ [ r~ L I' L L SUSPENDED SEDIMENT STRENGTH (mg·L -I) -65 - 7 I I I • I • 1000 6 '300100 (a)F ish exposed to sediment for 5 weeks. o (controls) w 160 ~ ~ w 120 U>zog;80 w 0::: (!)40z ow~0 L..I&lltmzL__m['L_-.lklJU~.~L_ Stream no.4 8 2 5 _200 (.) Q) rn- SUSPENDED SEDIMENT STRENGTH (mg·L -I) 7 1000'300 '3 6 100 2 5 (b)Naive fish (exposed to sediment for I hour). o Stream no.4 8 o (controls) 40 '360 (.) Q) ~240 w ~ ~200 w U> ~160 0- f3 0:::120 (!)z ow 80w LL '320 280- [ c ~ c [ c [ b -66 '- Figure 7.Illustration of effect of differing strengths of suspended placer mlnlng sediment on time to consume groups of 10 sub-surface drift organisms (Artemia salina) for underyearlirig Arctic grayling held in test streams for 6 weeks prior to testing.Bars r~present values derived for each trial,and broken extensions of bars re- present "greater than"values. [ [ r L [ [ [ L J- L r' I~ L 7 !I 1000 1000 ,,"I 300 300 5 -67 - 100 100 2 SUSPENDED SEDIMENT STRENGTH (mg·L -I ) 8 (b)Naive fish (exposed to sediment for I hour). o (c ontrols) o (controls) o Stream no. c:>z o 10wwu.. 60-c E 50 ---w ~40..- wen 30z 0a..en 20w 0:: (9z 100wwu.. 0 Stream no.4 60-(a)c Fish exposed to sediment ·5 for 5 weeks.......50 w ~ ~40 wenz 300a..enw 0::20 I' L [ r~ L [ [ [ [~ nLJ [ [ b~ E C C r..~13 [ L SUSPENDED SEDIMENT STRENGTH (mg·L-I) -68 - Figure 8.Illustration of effect of differing strengths of suspended placer mlnlng sediment on time to consume groups of 10 benthic worms (tubificids)for underyearling Arctic grayling held in test streams for (a)5 weeks or (b)1 hour pdor to testing.Bars represent values de- rived fqr each tri,H and broken extensions of bars repre- sent "greater than"values.. [ r~ L [ . [ c [ L [ L I L r L L SUSPENDED SEDIMENT STRENGTH -69 - 7 1000 6 (mg·L-I) 300 5 100 24 8 o(c antrals) 60 10 Streamna.------ 50 -c: E- w 40~ I- W Cf) Z 0 Cl.30Cf) W 0: (!) Z 0 Ww 20I.L.. [ [ [ [ [ r: r: r~ r~ LJ I' L -70 - Figure 9.Effect of 3-week exposure of underyearling Arctic gray ... ling to suspended placer mining sediment on their acute lethal tplerance to the reference toxicant pentachloro- phenol.Points represent lethal times to 50%mortality of fish (LT50),bars represent 95%confidence intervals. r L [ [ [ [ C [ l I 7 1000 3 6 300 -71 - 2 5 100 r 325r- 225 250 350 200 '----~---~---------------- Stream no.4 8 o(controls) -c E-300 :I: ~ W 0 0~ 275 w ~-~ f' L Ie L SUSPENDED SEDIMENT STRENGTH (mg·L -I) Figure 10. -72 - Effect.of prolonged (6-week)exposure of under.;. yearling Arctic grayling to suspended placer mining sediment on their acute lethal tolerance to the reference toxicant pentachlorophenol.Points represent lethal times to 50%mortality of fish (LT50),bars represent 95%confidence intervals. [ [ [ [ C [ L r' L f' L L SUSPENDED SEDIMENT STRENGTH (mg·L -I) I 7 1000 3 6 300 2 5 100 4 8 O(controls) -73 - 110 120 170 160 180 100 L.-_ Stream no. -150 c E- :I: ~140w 0 0 I- W ::E 130 I- r L [ [ [ [ [ [ [ [ I ' L r L Figure 11. -74 - Effect of prolonged (6-week)exposure of unde~~ yearling Arctic grayling to suspended placer mining s~diment on their residual dissolved oxygen values at death in sealed jar bioassays.Points represent mean values,bars represent 95%confidence intervals. r~L. - [ b [ [ [ r' L f' L -75 - SUSPENDED SEDIMENT STRENGTH (mg·L -I) I 7 1000 3 6 300 2 5 100 4 8 o(controls) 3.6 3.4 3.2 2.0 L-_ Stream no. - I 3.0 .....J Ct E- Z IJJ 2.8(!) )0- X 0 0 IJJ>2.6.....J 0enen 0 .....J <t:::>2.40 CJ) IJJa:: 2.2 r= L rI, L2 r L L [ L [ [ [ [ 1-' L.; Figure 12. -76 - Effect of p~olonged (6-week)exposure of under- yearling Arctic grayling to suspenp-edplacer mining sediment on their time to death in sealed jar bioassays.Points represent lethal times to 50% mortality of fish (LT50),bars represent 95% confidence intervals. r~ L [ [ C [ [ [ ~-~ I' L r . IL~ L I 7 1000 3 6 300 -77 - 2 5 100 SUSPENDED SEDiMENT STRENGTH (mg·L-I) 350 325 250 375 225 -c E-300 ::I: ~ W 0 ~ 275 w ::E-~ 20J----------------------- Stream no.4 8 O(controls) r L [ [ [ [ , [ [ r' [' [ E C [ E [ [ Figure 13. -78 - Effect of prolonged (6-week)exposure of under- yearling Arctic grayling to suspended placer mining sediment on their upper lethal temperature tolerance.Points represent mean temperatures at death,bars represent 95%confidence intervals. [ [ [ r~ I r-' L r L [ [ [ L '"L r" IL~ t ----- 28.5 I 7 1000 (mg·L-I) 3 6 300 -79 - 2 5 100 SUSPENDED SEDIMENT STRENGTH 4 8 o(controls) 26.0 1------------------- Stream no. 28.0 ~~~-r ~u 0- ~27.5 IJ.J 0 ~ IJ.Ja::27.0::::> !ia:: IJ.J Q. ~ IJ.J I- 26.5 [ [ [ [ [ [ [ [ [ APPENDIX 1.Daily water quality characteristics in test streams during prolonged exposure of underyearling Arctic grayling to differing strengths of suspended placer mining sediment. Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(OC)a (mg.L-1 )a pHa (umho.cm-1 )a (mg.L-1 )a (FTu)a (ml·min-1 ) 14/07183 0 4 14.5 9.6 6.4 14 <5 1 _b 0 8 13.9 9.6 6.4 14 <5 1 0 2 14.4 9.5 6.4 14 <5 1 0 5 14.5 9.6 6.3 15 <5 1 0 3 14.4 9.6 6.l.1 14 <5 1 0 6 14.4 9.5 6.L1 14 <5 1 0 1 14.3 9.6 6.4 15 <5 1 0 7 14.4 9~6 6.4 14 <5 1 15/07183 0 4 14.4 9.5 6.3 15 <5 1 00 0 8 13.8 9.5 6.4 14 <5 1 0 0 2 14.3 9.5 6.3 15 <5 1 0 5 14.6 9.7 6.3 15 <5 1 0 3 14.5 9.5 6.2 15 <5 1 0 6 14.2 9.5 6.3 14 <5 1 0 1 14.3 9.5 6.3 14 <5 1 0 7 14.3 9.5 6.3 15 <5 1 16/07183 0 4 14.5 9.6 6.4 13 <5 1 270 0 8 13.8 9.8 6.3 13 <5 1 250 0 2 14.3 9.5 6.4 14 <5 590 0 5 14.8 9.5 6.3 13 <5 1 490 0 3 14.6 9.6 6.2 13 <5 1 430 0 6 14.4 9.6 6.5 13 <5 1 330 0 1 14.3 9.6 6.1 14 <5 1 700 0 7 14.4 9.8 6.3 13 <5 1 490 aSampled/determined mid-stream. bNot determined. r---,~,r--- ~,J to ,J APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(Oc)a (mg.L-1)a pHa (umho·cm-1 )a (mg·L-1)a (FTu)a (ml'min-1 ) 17/07/83 0 4 13.2 9.7 6.2 13 <5 1 280 0 8 12.6 9.6 6.3 13 <5 1 270 0 2 13.2 9.8 6.1 13 <5 1 590 0 5 13.6 9.4 6.2 13 <5 1 500 0 3 13.4 9.7 6.3 14 <5 1 420 0 6 13.2 9.4 6.3 12 <5 1 340 0 1 13.3 9.8 6.2 13 <5 1 700 0 7 13.4 9.2 6.3 12 <5 1 490 18/07183 0 4 14.0 9.7 6.5 18 <5 1 260 0 8 13.4 9.7 6.6 18 <5 1 230 00 0 2 14.0 10.0 6.6 16 <5 1 550 ..... 0 5 14.2 9.8 6.6 16 <5 1 455 0 3 14.2 10.0 6.5 17 <5 1 395 0 6 13.9 9.7 6.5 18 <5 1 305 0 1 14.0 10.1 6.6 18 <5 1 650 0 7 14.0 9.8 6.6 16 <5 1 465 19/07/83 0 4 14.4 10.1 6.8 17 <5 1 245 0 8 13.6 10.5 6.9 17 <5 1 230 0 2 14.6 10.0 6.8 15 <5 1 545 0 5 14.8 10.1 6.8 17 <5 1 455 0 3 14.7 10.0 6.9 16 <5 1 390 0 6 14.5 10.1 6.8 16 <5 1 305 0 1 14.7 9.9 6.8 17 <5 1 635 0 7 14.6 10.1 6.8 17 <5 1 460 aSampled/determined mid-stream. APPENDIX 1 (cont.'d.) Nomina.l sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-'I)no.(OC)a (mg.L-1)a pRa (umho·cm-1 )a (mg.L-1)a (FTU)a (ml·min-1 ) 20107/83 0 4 14.6 10.1 6.6 14 <5 1 270 0 8 14.0 9.6 6.3 14 <5 1 240 0 2 14.3 10.0 6.8 14 <5 1 600 0 5 14.8 10.0 6.5 13 <5 1 500 0 3 14.7 10.1 6.7 13 <5 1 440 0 6 14.6 10.1 6.4 14 <5 1 330 0 1 14.4 9.9 6.6 14 <5 1 690 0 7 14.7 10.0 6.4 13 <5 1 510 21/07/83 0 4 14.4 9.2 6.7 23 <5 1 59 0 8 13.1 9.9 6.7 22 <5 1 66 co 100 2 14.2 9.2 6.8 23 7 27 68 N 100 5 14.6 9.2 6.6 23 <5 27 65 300 3 14.5 9.4 6.8 23 74 100 68 300 6 14.1 9.8 6.7 23 88 98 69 1000 1 14.0 9.6 6.8 27 264 320 68 1000 7 13.9 9.6 6.7 23 313 340 70 22/07/83 0 4 15.3 9.9 7.2 22 <5 1 68 0 8 13.9 10.2 7.3 22 <5 1 70 100 2 15.0 9.7 7.0 23 60 105 66 100 5 15.6 9.6 7.2 22 53 80 73 300 3 15.4 9.7 7.0 27 240 285 68 300 6 15.1 9.5 7.3 26 203 260 68 1000 1 14.9 9.8 6.8 35 860 1400 68 1000 7 14.9 9.6 7.2 35 833 1400 70 aSampled/deterrnined mid-stream. ....----, i APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(oC)a (mg.L-1)a pHa (umho'cm-1 )a (mg.L-1)a (FTu)a (ml'min-1 ) 23/07/83 0 4 15.5 9.2 6.9 23 <5 2 72 0 8 14.1 9.6 6.7 23 <5 2 74 100 2 15.2 9.5 7.1 25 56 76 70 100 5 15.8 9.1 6.8 25 50 74 76 300 3 15.6 9.5 7.0 28 223 220 67 300 6 15.2 9.3 6.9 28 220 260 63 1000 1 14.9 9.3 7.2 36 963 1600 69 1000 7 15.0 9.4 7.2 36 863 1480 70 24/07/83 0 4 15.2 9.6 6.9 23 <5 1 71 0 8 13.8 9.8 6.9 23 <5 1 73 co 100 2 15.1 9.6 7.0 24 47 96 69 w 100 5 15.7 9.6 7.1 24 48 88 74 300 3 15.5 9.5 7.0 27 223 290 66 300 6 15.1 9.4 6.9 29 204 280 62 1000 1 15.2 9.7 7.0 38 773 1400 67 1000 7 14.8 9.8 7.0 33 893 1400 68 25/07/83 0 4 15.3 9.4 6.5 25 <5 1 71 0 8 13.8 10.5 6.7 21 <5 1 72 100 2 15.1 9.5 6.6 27 54 75 68 100 5 15.7 9.4 6.5 26 40 75 75 300 3 15.5 9.4 6.5 30 220 300 70 300 6 15.1 9.4 6.6 30 193 300 65 1000 1 14.9 9.3 6.8 37 855 1520 72 1000 7 14.6 9.6 6.3 36 870 1400 72 aSampled/determined mid-stream. APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg·L--1 )no.(Oc)a (mg·L-1)a pHa (umho.cm-1 )a (mg.L-1)a (FTu)a (ml·min-1 ) 26/07/83 0 II 15.2 9.4 6.4 27 <5 1 71 0 8 13.9 9.6 6.4 25 <5 1 72 100 2 15.0 9.5 6.5 27 64 102 69 100 5 15.7 9.4 6.4 26 56 75 74 300 3 15.4 9.4 6.5 31 200 230 70 300 6 15.2 9.5 6.5 31 180 280 64 1000 1 14.8 9.4 6.6 37 920 1400 70 1000 7 15.0 9.3 6.6 37 780 1360 7.2 27/07/83 0 4 15.2 9.6 6.5 20 <5 2 70 0 8 13.9 9.7 6.6 24 <5 2 72 co 100 2 15.0 9.5 6.5 18 60 70 70 .j:::> 100 5 15.7 9.5 6.6 21 61 95 74 300 3 15.4 9.5 6.6 19 246 330 71 300 6 15.2 9.5 6.6 22 204 270 68 1000 1 14.8 9.7 6.7 17 843 1400 72 1000 7 14.9 9.4 6.6 23 790 1400 73 28/07/83 0 4 13.7 9.9 6.6 19 <5 2 70 0 8 12.8 10.0 6.6 28 <5 3 72 100 2 14.1 9.6 6.7 20 104 115 68 100 5 14.1 9.6 6.7 21 102 145 74 300 3 14.1 9.7 6.6 22 275 490 69 300 6 14.0 9.6 6.6 19 262 600 70 1000 1 14.1 9.8 6.7 32 890 1400 71 1000 7 13.7 10.0 6.6 21 900 1400 72 aSampled/determined mid-stream. L ..J ~f ,_...J ',J _:----, ,i _--j OlD,~J ,----, c .....J APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (rog.L-'I)no.(oC)a (rog·L-1)a pHa (umho·cm-1 )a (rog.L-1)a (FTU)a (ml·min-1) 29/07/83 0 4 14.9 9.4 6.6 23 <5 1 72 0 8 13.7 10.0 6.4 24 <5 2 72 100 2 14.8 9.4 6.7 23 57 75 69 100 5 15.3 9.2 6.5 24 74 110 74 300 3 15.1 9.4 6.8 27 256 360 70 300 6 14.8 9.5 6.6 27 256 340 70 1000 1 14.8 9.5 6.8 36 880 1440 72 1000 7 14.6 9.8 6.8 37 890 1600 73 30/07/83 0 4 15.7 9.5 6.4 21 <5 1 70 0 8 14.3 9.6 6.4 23 <5 1 72 co100215.5 9.3 6.l.1 22 57 85 73 U1 100 5 16.2 9.2 6.4 22 87 115 73 300 3 15.9 9.3 6.4 25 268 360 74 300 6 15.7 9.2 6.4 26 268 390 70 1000 1 15.3 9.5 6.5 34 860 1600 73 1000 7 15.4 9.3 6.6 33 847 1600 68 31/07183 0 4 15.5 9.3 6.3 23 <5 2 73 0 8 14.0 9.5 6.4 24 <5 1 72 100 2 15.3 9.3 6.4 24 78 90 70 100 5 15.9 9.4 6.4 24 100 110 69 300 3 15.7 9.3 6.5 27 282 320 70 300 6 15.3 9.6 6.5 28 256 350 68 1000 1 15.1 9.5 6.4 35 930 1560 70 1000 7 15.0 9.4 6.8 36 920 1480 66 aSampled/determined mid-stream. APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Tell1perature oxygen Conductance residue Turbidity rate Date (mg·L-1)no.(Oc)a (mg'L-1)a pHa (umho'cm-1 )a (mg.L-1)a (FTU)a (ml'min-1 ) 01/08/83 0 4 15.6 9.2 6.4 24 <5 1 73 0 8 14.3 9.4 6.5 26 <5 1 70 100 2 15.5 9.4 6.4 27 94 96 69 100 5 16.1 9.2 6.5 27 105 120 70 300 3 15.8 9.2 6.6 32 290 310 68 300 6 15.5 9.3 6.6 32 293 310 65 1000 1 15.3 9.3 6.5 39 950 1480 69 1000 7 15.4 9.2 6.7 39 1080 1560 65 02/08/83 0 4 14.9 9.4 6.5 22 <5 1 73 0 8 13.8 9.8 6.5 24 <5 2 71 00100214.9 9.4 6.5 27 108 140 70 O'l 100 5 15.3 9.0 6.6 26 119 140 70 300 3 15.2 9.4 6.6 28 332 400 70 300 6 14.9 9.3 6.'7 28 294 450 69 1000 1 14.9 9.5 6.5 35 1070 1800 70 1000 '7 14.7 9.3 6.8 37 1020 1600 66 03/08/83 0 4 15.1 9.4 6.6 24 <5 1 73 0 8 13.9 9.5 6.5 27 <5 1 72 100 2 15.0 9.2 6.8 29 122 140 72 100 5 15.6 9.4 6.6 27 127 100 71 300 3 15.3 9.4 6.8 29 342 370 71 300 6 15.1 9.2 6.6 31 376 460 70 1000 1 14.9 9.6 6.8 38 1160 1800 72 1000 7 14.9 9.3 6.7 41 1030 1760 66 aSampled/determined mid-stream. APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.V·1)no.(oc)a (mg.L-1)a pEa (umho.cm-1 )a (mg.L-1)a (FTu)a (ml·min-1) 04/08/83 0 4 14.8 9.7 6.4 17 <5 1 71 0 8 13.7 10.0 6.4 19 <5 1 70 100 2 14.9 9.2 6.7 31 102 165 69 100 5 15.3 9.4 6.6 28 79 110 68 300 3 14.9 9.6 6.7 25 365 410 70 300 6 14.3 9.8 6.5 25 350 400 68 1000 1 13.4 10.0 6.6 36 1120 1600 70 1000 7 13.3 10.2 6.5 29 1110 1600 65 05/08/83 0 4 15.8 9.4 6.5 31 <5 1 74 0 8 14.6 9.8 6.6 31 <5 1 73 00100215.5 9.4 6.5 31 110 135 72 -.....J 100 5 16.3 9.2 6.5 29 118 90 71 300 3 15.9 9.3 6.6 30 352 450 71 300 6 15.8 9.3 6.5 30 342 425 69 1000 1 15.1 9.7 6.7 37 1190 2200 71 1000 7 15.6 9.5 6.6 39 1100 2000 67 06/08/83 0 4 15.6 9.5 6.4 25 <5 1 70 0 8 14.4 9.4 6.6 28 <5 1 78 100 2 15.4 9.3 6.5 28 131 175 75 100 5 16.1 9.3 6.5 27 146 110 76 300 3 15.8 9.4 6.7 32 350 450 75 300 6 15.6 9.5 6.5 33 342 425 72 1000 1 15.1 9.5 6.7 39 1110 2000 72 1000 7 15.4 9.3 6.8 41 1120 2000 73 aSampled/determined mid-stream. APPENDIX 1 (corrt'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(oc)a (mg·L-1)a pHa (umho'cm-1 )a (mg.L-1)a (FTu)a (ml'min-1 ) 07/08/83 ()4 15.6 9.3 6.4 23 <5 1 71 ()8 14.4 9.7 6.4 23 <5 1 75 100 2 15.3 9.4 6.7 27 144 190 75 100 5 16.0 9.2 6.4 24 131 140 75 300 3 15.7 9.4 6.7 28 354 450 73 300 6 15.6 9.4 6.6 29 306 450 70 1000 1 15.1 9.6 6.9 37 1100 2000 71 1000 7 15.4 9.4 6.7 36 1060 1800 74 08/08/83 0 4 15.4 9.5 6.5 26 <5 1 72 0 8 14.1 9.6 6.4 25 <5 1 76 co 100 2 15.2 9.4 6.8 28 117 160 75 co 100 5 15.9 9.5 6.5 27 125 125 76 300 3 15.7 9.4 6.7 31 337 400 74 300 6 15.4 9.4 6.7 32 290 400 71 1000 1 15.0 9.5 6.8 37 1090 1900 72 1000 7 15.2 9.3 6.8 39 1030 1700 73 09/08/83 0 4 15.2 9.3 6.4 27 <5 1 72 0 8 13.9 9.4 6.4 24 <5 1 76 100 2 15.1 9.4 6.7 29 120 150 73 100 5 15.7 9.1 6.5 27 123 110 73 300 3 15.5 9.3 6.7 31 327 400 71 300 6 15.2 9.3 6.5 33 312 400 68 1000 1 14.9 9.4 6.7 38 1130 1900 71 1000 7 15.1 9.5 6.6 39 1060 1600 70 aSampled/determined mid-stream. iI ,--, L.j L J APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg·L-1)no.(Oc)a (mg·L-1)a pHa (umho·cm-1 )a (mg.L-1)a (FTu)a (ml·min-1 ) 10/08/83 0 4 15.4 9.5 6.5 26 <5 1 70 0 8 14.3 9.6 6.4 25 <5 1 76 100 2 15.2 9.4 6.6 27 99 120 73 100 5 15.8 9.2 6.5 29 95 120 75 300 3 15.6 9.4 6.6 30 334 450 73 300 6 15.4 9.3 6.5 32 380 400 70 1000 1 15.1 9.4 6.5 37 1160 2000 72 1000 7 15.3 9.4 6.5 39 1100 1920 72 11/08/83 0 4 14.9 9.5 6.4 14 <5 1 70 0 8 13.6 10.0 6.5 14 <5 1 75 co 100 2 14.6 9.7 6.5 16 117 130 72 <..0 100 5 15.1 9.5 6.6 16 105 170 72 300 3 15.1 9.4 6.5 19 303 550 71 300 6 14.3 9.8 6.5 19 313 500 69 1000 1 13.8 10.0 6.6 27 1040 2000 71 1000 7 13.3 9.8 6.6 27 1060 2200 70 12/08/83 0 4 15.4 9.4 6.4 24 <5 1 70 0 8 14.3 9.6 6.4 23 <5 1 75 100 2 15.2 9.4 6.6 29 109 105 71 100 5 15.9 9.2 6.4 30 122 130 72 300 3 15.7 9.5 6.5 31 331 390 72 300 6 15.5 9.2 6.5 29 300 400 68 1000 1 15.1 9.3 6.7 36 1080 1880 70 1000 7 15.4 9.2 6.5 39 1010 1900 71 aSampled/determined mid-stream. APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(oc)a (mg.L-1)a pHa (umho·cm-1 )a (mg.L-1)a (FTu)a (ml·min-1 ) 13/08/83 0 4 15.3 9.4 6.5 27 <5 <1 75 0 8 14.3 9.8 6.5 26 <5 <1 75 100 2 15.0 9.4 6.6 27 97 105 76 100 5 15.9 9.3 6.5 27 98 130 77 300 3 15.4 9.2 6.6 32 305 380 71 300 6 15.4 9.5 6.6 31 308 400 76 1000 1 14.8 9.5 6.6 37 1020 1680 74 1000 7 15.3 9.4 6.8 38 1010 1600 77 14/08/83 0 4 14.4 9.5 6.5 25 <5 2 74 0 8 13.6 9.9 6.5 26 <5 1 74 100 14.3 6.6 87 \.029.7 27 130 75 a 100 5 14.8 9.4 6.5 28 83 150 75 300 3 14.6 9.4 6.7 40 253 250 70 300 6 14.4 9.1 6.8 41 225 280 74 1000 1 14.4 9.7 6.7 43 850 1400 70 1000 7 14.4 9.3 6.7 43 863 1400 75 15/08/83 0 4 15.0 9.3 6.5 27 <5 <1 71 0 8 13.8 9.7 6.5 25 <5 1 72 100 2 14.9 9.3 6.6 28 99 110 73 100 5 15.5 9.1 6.5 28 120 135 74 300 3 15.2 9.3 6.6 32 271 330 69 300 6 15.0 9.3 6.5 31 282 350 71 1000 1 14.2 9.4 6.7 39 1010 1680 69 1000 7 15.0 9.4 6.7 38 905 1680 72 aSampled/determined mid-stream. r---~L J r -~r---""'1 !'r;I l,J""~..l.,,j APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(oc)a (mg.L-1 )a pHa (umho'cm-1 )a (mg.L-1)a (FTu)a (ml'min-1) 16/08/83 0 4 15.1 9.2 6.5 28 <5 1 73 0 8 14.0 9.4 6.4 28 <5 1 74 100 2 15.0 9.3 6.7 29 93 125 75 100 5 15.5 9.2 6.5 29 126 150 74 300 3 15.3 9.3 6.7 32 314 400 69 300 6 15.1 9.2 6.5 32 297 400 72 100O 1 14.8 9.5 6.7 36 1010 1640 69 1000 7 15.0 9.2 6.6 38 969 1680 73 17/08/83 0 4 14.9 9.2 6.6 33 <5 1 73 0 8 13.9 9.5 6.6 29 <5 1 74 1.0 100 2 14.9 9.2 6.6 35 99 95 73 I-' 100 5 15.3 9.2 6.6 31 113 145 73 300 3 15.2 9.1 6.7 36 311 350 68 300 6 14.9 9.1 6.6 35 291 380 72 1000 1 14.8 9.2 6.7 38 1060 1680 69 1000 7 14.8 9.1 6.7 41 999 1800 73 18/08/83 0 4 14.9 9.6 6.4 20 <5 1 72 0 8 13.8 10.2 6.5 23 <5 1 74 100 2 14.8 8.9 6.6 23 101 135 74 100 5 15.2 9.3 6.5 23 116 160 72 300 3 15.2 9.3 6.6 25 349 500 68 300 6 14.6 9.6 6.5 25 283 400 72 1000 1 14.4 9.2 6.6 34 1310 2000 69 1000 7 14.2 9.8 6.6 32 1060 1600 72 aSampled/determined mid-stream. APPENDIX 1 (cQnt'do.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-·1 )no.(Oc)a (mg.L-1)a pHa (umho-cm-1)a (mg.L-1)a (FTU)a (ml'min-1 ) 19/08/83 0 4 15.3 9.2 6.5 22 <5 1 74 0'B 14.0 9.5 6.5 23 <5 1 73 100 2 15.2 9.4 6.7 24 102 110 73 100 5 15.6 9.2 6.7 23 113 150 74 300 3 15.5 9.3 6.7 26 297 410 70 300 6 15.0 9.2 6.6 26 297 450 73 1000 1 15.1 9.4 6.7 35 972 1800 69 1000 7 14.8 9.3 6.7 33 1090 1920 74 20/08/83 0 4 15.3 9.1 6.6 27 <5 <1 76 0 8 14.3 9.6 6.5 28 <5 <1 74 6.7 74 \.0100215.2 9.5 27 110 77 N 100 5 15.7 9.2 6.6 28 95 145 78 300 3 15.5 9\1 6.7 31 261 340 73 300 6 15.3 9.3 6.6 31 255 340 74 1000 1 15.1 9.4 6.6 36 947 1720 74 1000 7 15.2 9.2 6.6 40 944 1600 74 21/08/83 0 4 15.8 9.3 6.5 31 <5 1 76 0 8 14.5 9.4 6.5 31 <5 1 75 100 2 15.5 9.2 6.6 29 62 120 75 100 5 16.2 9.0 6.5 29 85 130 76 300 3 15.9 9.2 6.6 32 281 350 72 300 6 15.7 9.1 6.6 31 256 330 74 1000 1 15.4 9.4 6.7 36 918 1600 74 1000 7 15.6 9.0 6.5 37 896 1400 73 aSampled/determined mid-stream. r--",l :,....,j ;-j I r--]':-l r---'"'1 ,.J APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L-1)no.(oc)a (mg'L-1)a pHa (umho.cm-1 )a (mg.L-1 )a (FTU)a (ml·min-1) 22/08/83 0 4 14.9 9.1 6.5 32 <5 1 76 0 8 13.9 9.2 6.6 31 <5 1 74 100 2 15.0 9.3 6.6 32 91 115 73 100 5 15.3 9.0 6.5 32 105 115 72 300 3 15.2 9.3 6.6 35 307 360 70 300 6 15.0 9.0 6.5 35 283 340 70 1000 1 15.0 9.3 6.6 39 972 1520 73 1000 7 15.0 8.8 6.6 41 935 1400 72 23/08/83 0 4 15.5 9.2 6.5 32 <5 1 76 0 8 14.2 9.8 6.5 29 <5 1 73 ~ 100 2 15.4 9.1 6.6 32 65 130 74 w 100 5 15.9 9.2 6.5 30 94 140 74 300 3 15.7 9.2 6.6 34 264 350 70 300 6 15.5 9.2 6.6 33 237 360 72 1000 1 15.2 9.2 6.5 37 868 1600 73 1000 7 15.4 9.2 6.7 38 854 1400 72 24/08/83 0 4 15.0 9.4 6.4 32 <5 2 76 0 8 1J.8 9.4 6.4 28 <5 1 74 100 2 15.0 9.2 6.6 31 93 120 74 100 5 15.4 9.3 6.5 31 114 165 73 300 3 15.3 9.2 6.4 33 335 450 70 300 6 14.9 9.5 6.5 33 274 380 70 1000 1 15.0 9.5 6.7 37 942 .1720 72 1000 7 14.8 9.2 6.4 37 912 1280 71 aSampled/determined mid-stream. APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.L,-1 )no.(OC)a (mg.L-1)a pHa (umho·cm-1 )a (mg.L-1)a (FTU)a (ml·min-1) 25/08/83 0 4 14.9 9.6 6.5 15 <5 <1 74 0 8 13.8 9.6 6.4 16 <5 1 70 100 2 14.9 9.5 6.5 18 85 140 71 100 5 15.2 9.6 6.5 18 82 160 70 300 3 15.1 9.4 6.5 20 328 450 67 300 6 14.6 9.4 6.6 20 361 50b 69 1000 1 14.6 9.5 6.6 29 1130 2000 72 1000 7 14.5 9.7 6.4 30 1130 2000 66 26/08/83 0 4 15.4 9.0 6.7 23 <5 <1 75 0 8 14.3 9'~4 6.6 21 <5 <1 73 6.8 54 125 72 <.0100215.3 9.3 21 .p, 100 5 15.8 9.0 6.6 23 68 130 72 300 3 15.5 9.4 6.8 27 216 325 69 300 6 15.3 9.2 6.7 24 226 325 70 1000 1 15.1 9.2 6.8 33 833 1500 72 1000 7 15.3 9.0 6.8 34 798 1500 71 27/08/83 ()4 15.5 9.5 6.6 27 <5 <1 76 ()8 14.3 9.8 6.6 28 <5 <1 75 100 2 15.3 8.9 6.7 26 59 115 76 100 5 16.0 9.0 6.7 28 73 135 75 300 3 15.7 8.9 6.8 30 314 300 72 300 6 15.6 9.0 6.6 31 302 350 74 1000 1 15.2 8.9 6.7 37 978 1700 74 1000 7 15.4 9.1 6.7 37 876 1680 76 aSampled/determined mid-stream. APPENDIX 1 (cont'd.) Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg.V-1 )no.(oC)a (mg·L-1)a pHa (umho·cm-1 )a (mg·L-1)a (FTU)a (ml·min-1) 28/08/83 0 4 15.1 9.6 6.5 24 <5 1 76 0 8 14.0 10.0 6.5 23 <5 <1 74 100 2 15.2 9.0 6.7 24 86 115 72 100 5 15.5 8.9 6.6 23 86 140 74 300 3 15.4 9.1 6.8 27 218 350 71 300 6 15.1 9.1 6.6 26 212 350 68 1000 1 15.2 8.9 6.6 34 933 1600 70 1000 7 15.1 9.4 6.6 33 867 1500 72 29/08/83 0 4 15.3 9.1 6.5 29 <5 <1 77 0 -8 14.2 9.2 6.6 29 <5 <1 76 <.D 100 2 15.4 9.0 6.7 29 57 105 73 (J1 100 5 15.8 8.9 6.5 30 69 110 73 300 3 15.6 9.0 6.7 36 251 270 72 300 6 15.3 9.0 6.6 34 230 325 66 1000 1 15.3 9.1 6.7 38 895 1440 70 1000 7 15.3 8.8 6.6 42 834 1200 72 30/08/83 0 4 15.5 9.1 6.6 28 <5 <1 75 0 8 14.3 9.3 6.6 25 <5 <1 73 100 2 15.3 9.1 6.7 30 58 115 72 100 5 15.9 9.0 6.6 29 64 110 73 300 3 15.7 9.1 6.8 34 197 230 71 300 6 15.5 9.0 6.6 32 206 300 66 1000 1 15.3 9.4 6.9 35 820 1400 70 1000 7 15.5 9.0 6.6 39 779 1200 72 aSampled/determined mid-stream. APPENDIX 1 (oont"d.•)""', Nominal sediment Dissolved Nonfiltrable Inflow strength Stream Temperature oxygen Conductance residue Turbidity rate Date (mg'L-l)no.(oc)a (mg.L-l)a pHa (umho'cm-1)a (mg.L-l)a (FTU)a (ml'min-1) 31/08/83 0 4 15.2 9.5 6.6 28 <5 <1 76 0 8 14.1 9.8 6.6 25 <5 <1 76 100 2 15.1 9.7 6.6 29 76 125 72 100 5 15.6 9.5 6.5 29 85 125 72 300 3 15.4 9.5 6.6 33 277 260 69 300 6 15.2 9.5 6.7 32 255 325 65 1000 1 15.0 9.9 6.6 38 990 1400 69 1000 7 15.1 9.3 6.7 39 859 1400 70 01/09/83 0 4 15.1 9.9 6.4 35 <5 <1 75 . 0 8 14.1 10.6 6.6 30 <5 <1 77 ~100 2 15.2 9.8 6.4 36 55 110 72 O"'l 100 5 15.5 9.9 6.5 35 66 115 72 300 3 15.,4 9.9 6.5 37 217 300 69 300 6 15.0 9.9 6.5 39 253 340 64 1000 1 15.2 9.9 6.4 49 855 1400 69 1000 7 15.0 9.8 6.5 50 846 1360 70 aSampled/determined mid-stream.